Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Gambell_raw-data
SDR 5.3.1 -----Logger Information----- Model # Serial # 2542 Hardware Rev. 009-008-000 -----Site Information----- Site # 0030 Site Desc Gambell Project Code Project Desc www.akenergyauthority.org Site Location 100' NRG HD Tall Tower, tubular tilt-up Site Elevation 20 ft Latitude N 63° 46.748' Longitude W 171° 42.828' Time offset (hrs) -9 -----Sensor Information----- Channel # 1 Type 1 Description NRG #40 Anem, m/s Details boom orientation: NW Serial Number SN: Height 30m Scale Factor 0.765 Offset 0.35 Units m/s Channel # 2 Type 1 Description NRG #40 Anem, m/s Details boom orientation: North Serial Number SN: Height 20m Scale Factor 0.765 Offset 0.35 Units m/s Channel # 3 Type 0 Description No Sensor Details Serial Number SN: Height ft Scale Factor 0 Offset 0 Units Channel # 4 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 5 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 6 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 7 Type 3 Description #200P Wind Vane Details boom orientation: 155 degrees True Serial Number SN: Height 30 m Scale Factor 0.351 Offset 305 Units deg Channel # 8 Type 0 Description No Sensor Details Serial Number SN: Height 0 Scale Factor 0 Offset 0 Units Channel # 9 Type 4 Description NRG 110S Temp, C Details Serial Number SN: Height 4 m Scale Factor 0.136 Offset -86.38 Units C Channel # 10 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 11 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 12 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Date & Time Stamp CH1Avg CH1SD CH1Max CH1Min CH2Avg CH2SD CH2Max CH2Min CH3Avg CH3SD CH3Max CH3Min CH4Avg CH4SD CH4Max CH4Min CH5Avg CH5SD CH5Max CH5Min CH6Avg CH6SD CH6Max CH6Min CH7Avg CH7SD CH7Max CH7Min CH8Avg CH8SD CH8Max CH8Min CH9Avg CH9SD CH9Max CH9Min CH10Avg CH10SD CH10Max CH10Min CH11Avg CH11SD CH11Max CH11Min CH12Avg CH12SD CH12Max CH12Min 09/18/2004 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 12:40:00 0.4 0.3 2.6 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 303 17 305 305 0 0 0 0 -84.8 12.3 7.9 -86.4 09/18/2004 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 16:40:00 0.4 0 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 16:50:00 1.1 2.1 8 0.4 2.7 3.2 8 0.4 0.4 0 0.4 0.4 305 0 305 305 0 0 0 0 -86.4 0 -86.4 -86.4 09/18/2004 17:00:00 6.7 0.8 8.4 4.6 6.6 0.8 8.8 4.6 0.4 0 0.4 0.4 24 76 305 305 0 0 0 0 -0.8 28 52.9 -86.4 09/18/2004 17:10:00 6.5 0.6 8 4.9 6.3 0.7 8 4.6 0.4 0 0.4 0.4 74 5 72 305 0 0 0 0 6.9 0 7.4 6.9 09/18/2004 17:20:00 6.4 0.6 8.4 4.9 6.2 0.6 7.6 4.9 0.4 0 0.4 0.4 73 6 74 305 0 0 0 0 6.8 0.1 7.4 6.4 09/18/2004 17:30:00 5.9 0.7 7.6 4.2 5.8 0.7 7.6 4.2 0.4 0 0.4 0.4 78 8 75 305 0 0 0 0 6.7 0.1 7.2 6.4 09/18/2004 17:40:00 5.8 0.6 7.2 3.8 5.7 0.6 6.8 3.4 0.4 0 0.4 0.4 77 7 80 305 0 0 0 0 6.6 0 6.9 6.4 09/18/2004 17:50:00 6.2 0.6 7.6 4.6 6 0.7 7.6 4.6 0.4 0 0.4 0.4 77 8 85 305 0 0 0 0 6.5 0 6.9 6.4 09/18/2004 18:00:00 6 0.8 8 4.2 5.9 0.7 7.6 4.2 0.4 0 0.4 0.4 79 8 88 305 0 0 0 0 6.5 0 6.9 6.4 09/18/2004 18:10:00 6.2 0.6 7.6 4.6 6.1 0.6 7.2 4.6 0.4 0 0.4 0.4 74 6 69 305 0 0 0 0 6.5 0 6.9 6.4 09/18/2004 18:20:00 6.4 0.7 8 4.6 6.3 0.7 7.6 4.6 0.4 0 0.4 0.4 70 6 68 305 0 0 0 0 6.5 0 6.9 6.4 09/18/2004 18:30:00 6.5 0.6 8 4.6 6.4 0.6 8 4.9 0.4 0 0.4 0.4 69 4 66 305 0 0 0 0 6.6 0 6.9 6.4 09/18/2004 18:40:00 6.6 0.5 8 5.3 6.4 0.5 8 4.9 0.4 0 0.4 0.4 70 4 71 305 0 0 0 0 6.5 0 6.9 6.4 09/18/2004 18:50:00 6.6 0.4 8 5.3 6.4 0.4 8 4.9 0.4 0 0.4 0.4 68 4 71 305 0 0 0 0 6.6 0 6.9 6.4 09/18/2004 19:00:00 6.4 0.7 8 4.9 6.2 0.7 7.6 4.6 0.4 0 0.4 0.4 70 4 70 305 0 0 0 0 6.6 0 6.9 6.4 09/18/2004 19:10:00 6.7 0.7 8.4 4.6 6.6 0.7 8.4 4.9 0.4 0 0.4 0.4 67 4 65 305 0 0 0 0 6.7 0.1 7.2 6.4 09/18/2004 19:20:00 6.4 0.4 8 5.3 6.3 0.4 7.6 4.9 0.4 0 0.4 0.4 65 6 60 305 0 0 0 0 6.7 0.1 7.2 6.4 09/18/2004 19:30:00 6.3 0.7 8 4.6 6.2 0.7 7.6 4.2 0.4 0 0.4 0.4 69 5 66 305 0 0 0 0 6.7 0.1 7.2 6.4 09/18/2004 19:40:00 7.1 0.5 8.8 5.7 6.9 0.5 8.4 5.3 0.4 0 0.4 0.4 64 4 65 305 0 0 0 0 6.6 0.1 7.2 6.4 09/18/2004 19:50:00 6.9 0.6 8.4 5.3 6.9 0.6 8 5.3 0.4 0 0.4 0.4 53 5 58 305 0 0 0 0 6.7 0.1 7.2 6.4 09/18/2004 20:00:00 6.6 0.6 8 5.3 6.5 0.6 8.4 4.9 0.4 0 0.4 0.4 49 6 51 305 0 0 0 0 6.7 0.2 7.2 6.4 09/18/2004 20:10:00 6.6 0.4 7.6 5.7 6.5 0.5 8 5.3 0.4 0 0.4 0.4 43 8 41 305 0 0 0 0 6.7 0.1 7.2 6.4 09/18/2004 20:20:00 6.6 0.5 8.4 5.7 6.6 0.5 8 5.3 0.4 0 0.4 0.4 41 6 54 305 0 0 0 0 6.7 0.1 7.2 6.4 09/18/2004 20:30:00 7.1 0.6 8.8 5.3 7.1 0.7 8.4 5.3 0.4 0 0.4 0.4 34 4 39 305 0 0 0 0 6.6 0.1 7.2 6.4 09/18/2004 20:40:00 7.3 0.7 9.1 5.7 7.3 0.7 8.8 5.7 0.4 0 0.4 0.4 35 5 39 305 0 0 0 0 6.3 0.2 6.9 5.9 09/18/2004 20:50:00 7.8 0.8 9.5 6.1 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 30 5 24 305 0 0 0 0 6.2 0.1 6.7 5.9 09/18/2004 21:00:00 8.4 0.6 9.9 6.8 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 26 6 13 305 0 0 0 0 6.2 0 6.7 6.1 09/18/2004 21:10:00 8.5 0.6 9.9 6.8 8.5 0.6 9.9 7.2 0.4 0 0.4 0.4 25 4 28 305 0 0 0 0 6.3 0 6.7 6.1 09/18/2004 21:20:00 8.5 0.6 9.5 7.2 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 29 5 27 305 0 0 0 0 6.3 0 6.9 6.1 09/18/2004 21:30:00 8.7 0.5 9.9 7.2 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 29 5 33 305 0 0 0 0 6.3 0 6.9 6.1 09/18/2004 21:40:00 8.3 0.5 9.5 6.8 8.3 0.5 9.5 6.5 0.4 0 0.4 0.4 26 5 29 305 0 0 0 0 6.3 0 6.7 6.1 09/18/2004 21:50:00 8 0.5 9.1 6.5 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 21 5 23 305 0 0 0 0 6.3 0 6.9 6.1 09/18/2004 22:00:00 8.6 0.5 9.5 7.2 8.7 0.5 9.9 7.2 0.4 0 0.4 0.4 21 5 16 305 0 0 0 0 6.4 0 6.9 6.1 09/18/2004 22:10:00 8 0.9 9.9 5.7 7.9 0.8 9.5 5.3 0.4 0 0.4 0.4 42 17 59 305 0 0 0 0 6.3 0.2 6.9 5.6 09/18/2004 22:20:00 6.9 0.8 8.8 4.9 6.7 0.9 8.8 4.6 0.4 0 0.4 0.4 57 13 60 305 0 0 0 0 5.6 0.1 6.1 5.4 09/18/2004 22:30:00 7.7 0.7 9.9 5.7 7.7 0.8 9.9 5.7 0.4 0 0.4 0.4 45 7 51 305 0 0 0 0 5.6 0.1 6.1 5.4 09/18/2004 22:40:00 6.7 1.5 9.5 2.6 6.8 1.5 9.5 3.4 0.4 0 0.4 0.4 33 12 19 305 0 0 0 0 5.5 0.2 5.9 5.2 09/18/2004 22:50:00 8.5 0.6 9.5 6.5 8.6 0.6 9.9 6.8 0.4 0 0.4 0.4 18 5 25 305 0 0 0 0 5.8 0.1 6.4 5.6 09/18/2004 23:00:00 8.3 0.7 9.5 6.5 8.5 0.8 9.9 6.1 0.4 0 0.4 0.4 13 4 17 305 0 0 0 0 5.9 0 6.4 5.6 09/18/2004 23:10:00 7 0.4 8 5.7 7.1 0.4 8 6.1 0.4 0 0.4 0.4 24 7 22 305 0 0 0 0 6 0.1 6.4 5.9 09/18/2004 23:20:00 7.1 0.5 8.4 6.1 7.2 0.5 8.4 6.1 0.4 0 0.4 0.4 24 5 27 305 0 0 0 0 6 0.1 6.4 5.9 09/18/2004 23:30:00 7.5 0.5 8.8 6.1 7.6 0.5 9.1 6.5 0.4 0 0.4 0.4 27 5 23 305 0 0 0 0 6 0.1 6.4 5.9 09/18/2004 23:40:00 7.7 0.6 9.5 6.1 7.7 0.7 9.5 6.1 0.4 0 0.4 0.4 30 4 36 305 0 0 0 0 6.1 0.1 6.4 5.9 09/18/2004 23:50:00 8.2 0.4 9.1 6.8 8.3 0.5 9.1 6.5 0.4 0 0.4 0.4 35 3 33 305 0 0 0 0 5.8 0.1 6.4 5.4 09/19/2004 00:00:00 6.4 1.1 8.4 4.6 6.5 1 9.1 4.9 0.4 0 0.4 0.4 36 4 41 305 0 0 0 0 5.4 0.1 5.9 5.2 09/19/2004 00:10:00 6.4 0.8 8 4.6 6.4 0.8 8.4 4.6 0.4 0 0.4 0.4 48 6 61 305 0 0 0 0 5.7 0.1 6.1 5.4 09/19/2004 00:20:00 5.9 0.7 7.6 4.2 5.9 0.7 7.2 4.2 0.4 0 0.4 0.4 65 6 72 305 0 0 0 0 5.6 0.1 6.1 5.6 09/19/2004 00:30:00 4.3 0.6 5.7 2.6 4.3 0.6 5.7 2.6 0.4 0 0.4 0.4 68 6 70 305 0 0 0 0 5.6 0.1 6.1 5.6 09/19/2004 00:40:00 4.9 1.1 7.2 2.6 4.9 1.1 7.6 2.6 0.4 0 0.4 0.4 47 11 37 305 0 0 0 0 5.8 0.2 6.4 5.6 09/19/2004 00:50:00 6.3 0.4 7.6 5.3 6.4 0.4 7.6 5.3 0.4 0 0.4 0.4 45 5 52 305 0 0 0 0 5.9 0 6.4 5.6 09/19/2004 01:00:00 5.9 0.4 7.2 4.9 5.9 0.4 7.2 4.9 0.4 0 0.4 0.4 41 5 39 305 0 0 0 0 5.8 0 6.1 5.6 09/19/2004 01:10:00 6.7 0.4 7.6 5.7 6.8 0.4 8 5.7 0.4 0 0.4 0.4 37 4 37 305 0 0 0 0 5.8 0 6.1 5.6 09/19/2004 01:20:00 7.1 1 9.5 5.7 7.1 1 9.1 5.3 0.4 0 0.4 0.4 35 5 35 305 0 0 0 0 5.8 0 6.1 5.6 09/19/2004 01:30:00 7.7 1.3 9.9 4.6 7.7 1.3 9.9 4.9 0.4 0 0.4 0.4 40 9 36 305 0 0 0 0 5.3 0.1 6.1 4.9 09/19/2004 01:40:00 4.7 1.3 8.4 2.3 4.8 1.3 8.4 2.6 0.4 0 0.4 0.4 38 15 13 305 0 0 0 0 5.1 0.1 5.6 4.9 09/19/2004 01:50:00 7.6 0.6 9.1 6.5 7.8 0.6 9.5 6.5 0.4 0 0.4 0.4 13 6 358 305 0 0 0 0 5.4 0 5.9 5.2 09/19/2004 02:00:00 7.8 0.6 9.1 6.5 8 0.6 9.5 6.5 0.4 0 0.4 0.4 12 5 15 305 0 0 0 0 5.4 0.1 5.9 5.4 09/19/2004 02:10:00 7.9 0.6 9.1 6.5 8.1 0.7 9.5 6.1 0.4 0 0.4 0.4 9 6 10 305 0 0 0 0 5.3 0 5.9 4.9 09/19/2004 02:20:00 6.3 0.5 7.6 4.9 6.5 0.5 8 5.3 0.4 0 0.4 0.4 8 6 359 305 0 0 0 0 5.3 0.1 5.6 4.9 09/19/2004 02:30:00 6.6 0.7 8.4 4.9 6.8 0.7 8.4 4.9 0.4 0 0.4 0.4 24 8 30 305 0 0 0 0 5.6 0.1 5.9 5.4 09/19/2004 02:40:00 6.2 0.5 8 5.3 6.3 0.5 7.6 5.3 0.4 0 0.4 0.4 31 5 25 305 0 0 0 0 5.6 0.1 5.9 5.4 09/19/2004 02:50:00 6.5 0.7 8 4.9 6.6 0.7 8.4 5.3 0.4 0 0.4 0.4 26 4 30 305 0 0 0 0 5.7 0 6.1 5.6 09/19/2004 03:00:00 7.1 0.5 8.4 5.7 7.3 0.6 8.4 5.7 0.4 0 0.4 0.4 25 5 25 305 0 0 0 0 5.8 0 6.1 5.6 09/19/2004 03:10:00 6.9 0.5 8.4 5.7 7 0.5 8.4 5.7 0.4 0 0.4 0.4 27 5 37 305 0 0 0 0 5.8 0 6.1 5.6 09/19/2004 03:20:00 7.1 0.4 8.4 6.1 7.2 0.4 8.4 6.1 0.4 0 0.4 0.4 27 6 31 305 0 0 0 0 5.7 0 6.1 5.6 09/19/2004 03:30:00 7.1 0.5 8 5.7 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 26 6 25 305 0 0 0 0 5.7 0 5.9 5.6 09/19/2004 03:40:00 7.3 0.5 8.8 6.1 7.4 0.5 8.8 6.1 0.4 0 0.4 0.4 22 5 35 305 0 0 0 0 5.7 0 6.1 5.6 09/19/2004 03:50:00 7.2 0.5 8.8 5.7 7.4 0.5 8.8 6.1 0.4 0 0.4 0.4 21 4 13 305 0 0 0 0 5.7 0 5.9 5.6 09/19/2004 04:00:00 7.4 0.5 8.8 5.7 7.5 0.5 9.1 6.1 0.4 0 0.4 0.4 19 4 18 305 0 0 0 0 5.6 0.1 5.9 5.6 09/19/2004 04:10:00 7.3 0.6 8.8 5.7 7.4 0.6 8.8 5.3 0.4 0 0.4 0.4 20 5 14 305 0 0 0 0 5.6 0.1 5.9 5.4 09/19/2004 04:20:00 7.2 0.5 8.8 5.7 7.3 0.6 9.1 5.7 0.4 0 0.4 0.4 17 5 12 305 0 0 0 0 5.5 0.1 5.9 5.4 09/19/2004 04:30:00 6.9 0.6 8.4 5.3 7.1 0.6 8.8 5.3 0.4 0 0.4 0.4 20 5 18 305 0 0 0 0 5.5 0 5.9 5.4 09/19/2004 04:40:00 7.2 0.5 8.4 5.7 7.3 0.5 8.8 5.7 0.4 0 0.4 0.4 20 5 21 305 0 0 0 0 5.4 0 5.9 5.4 09/19/2004 04:50:00 7 0.6 8.8 5.3 7.2 0.6 9.1 5.7 0.4 0 0.4 0.4 15 5 15 305 0 0 0 0 5.4 0 5.9 5.4 09/19/2004 05:00:00 7.1 0.5 8.4 5.7 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 16 6 17 305 0 0 0 0 5.4 0 5.9 5.4 09/19/2004 05:10:00 7 0.5 8.8 5.7 7.2 0.5 8.8 5.7 0.4 0 0.4 0.4 11 4 10 305 0 0 0 0 5.4 0 5.9 5.4 09/19/2004 05:20:00 6.9 0.6 8.4 5.7 7.1 0.6 8.8 5.7 0.4 0 0.4 0.4 9 6 3 305 0 0 0 0 5.3 0 5.6 5.2 09/19/2004 05:30:00 7.8 0.5 9.1 6.1 8.1 0.5 9.5 6.5 0.4 0 0.4 0.4 5 4 3 305 0 0 0 0 5.4 0 5.9 5.4 09/19/2004 05:40:00 8 0.6 9.5 6.1 8.2 0.6 9.5 6.5 0.4 0 0.4 0.4 3 5 8 305 0 0 0 0 5.3 0 5.6 5.2 09/19/2004 05:50:00 8 0.5 9.1 6.5 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 2 4 3 305 0 0 0 0 5.2 0 5.6 4.9 09/19/2004 06:00:00 7.8 0.5 9.1 6.1 8.1 0.6 9.5 6.1 0.4 0 0.4 0.4 2 5 9 305 0 0 0 0 5.1 0 5.4 4.9 09/19/2004 06:10:00 8.1 0.4 9.1 6.8 8.3 0.4 9.5 7.2 0.4 0 0.4 0.4 4 3 1 305 0 0 0 0 5 0.1 5.4 4.9 09/19/2004 06:20:00 8.1 0.4 9.1 6.8 8.4 0.4 9.5 6.8 0.4 0 0.4 0.4 5 4 2 305 0 0 0 0 4.9 0.1 5.4 4.9 09/19/2004 06:30:00 7.8 0.6 9.1 6.1 8 0.6 9.5 6.1 0.4 0 0.4 0.4 6 6 22 305 0 0 0 0 4.8 0 5.4 4.7 09/19/2004 06:40:00 8.1 0.5 9.5 6.8 8.4 0.5 9.5 6.5 0.4 0 0.4 0.4 6 4 5 305 0 0 0 0 4.8 0 5.4 4.9 09/19/2004 06:50:00 8 0.5 9.1 6.5 8.3 0.6 9.5 6.5 0.4 0 0.4 0.4 9 5 12 305 0 0 0 0 4.8 0 5.4 4.7 09/19/2004 07:00:00 8 0.6 9.9 6.1 8.2 0.6 10.3 6.1 0.4 0 0.4 0.4 8 5 14 305 0 0 0 0 4.8 0 5.4 4.7 09/19/2004 07:10:00 8.3 0.5 9.9 7.2 8.6 0.5 9.9 7.2 0.4 0 0.4 0.4 11 4 5 305 0 0 0 0 4.8 0 5.2 4.7 09/19/2004 07:20:00 8.5 0.5 9.5 7.2 8.7 0.5 9.9 7.6 0.4 0 0.4 0.4 8 4 8 305 0 0 0 0 4.7 0 5.2 4.7 09/19/2004 07:30:00 8.1 0.7 9.9 6.5 8.3 0.7 10.7 6.1 0.4 0 0.4 0.4 4 4 2 305 0 0 0 0 4.8 0 5.2 4.7 09/19/2004 07:40:00 8.2 0.6 9.9 6.5 8.5 0.7 10.3 6.8 0.4 0 0.4 0.4 8 4 6 305 0 0 0 0 4.8 0 5.2 4.7 09/19/2004 07:50:00 8.4 0.6 9.9 6.5 8.6 0.6 10.3 6.5 0.4 0 0.4 0.4 7 4 12 305 0 0 0 0 4.7 0 5.2 4.7 09/19/2004 08:00:00 8.5 0.6 9.9 6.8 8.7 0.6 9.9 7.2 0.4 0 0.4 0.4 7 4 11 305 0 0 0 0 4.7 0 5.2 4.7 09/19/2004 08:10:00 8.8 0.6 10.3 6.8 9.1 0.7 10.3 7.2 0.4 0 0.4 0.4 2 4 2 305 0 0 0 0 4.7 0 5.2 4.4 09/19/2004 08:20:00 8.4 0.6 10.3 6.8 8.7 0.6 10.3 7.2 0.4 0 0.4 0.4 0 5 356 305 0 0 0 0 4.5 0 4.9 4.4 09/19/2004 08:30:00 8.6 0.6 9.9 6.5 8.8 0.7 10.3 6.8 0.4 0 0.4 0.4 0 7 6 305 0 0 0 0 4.5 0.1 4.9 4.4 09/19/2004 08:40:00 8.5 0.7 9.9 6.5 8.7 0.8 10.3 6.5 0.4 0 0.4 0.4 357 6 358 305 0 0 0 0 4.5 0.1 4.9 4.2 09/19/2004 08:50:00 8.3 0.6 9.5 6.5 8.6 0.7 10.3 6.5 0.4 0 0.4 0.4 1 5 358 305 0 0 0 0 4.4 0.1 4.9 4.4 09/19/2004 09:00:00 8.5 0.7 9.9 6.5 8.7 0.7 10.3 6.5 0.4 0 0.4 0.4 1 6 4 305 0 0 0 0 4.4 0.1 4.9 4.4 09/19/2004 09:10:00 8.3 0.6 9.9 6.1 8.6 0.6 10.3 6.5 0.4 0 0.4 0.4 1 5 3 305 0 0 0 0 4.4 0 4.7 4.4 09/19/2004 09:20:00 8.1 0.6 9.9 6.5 8.4 0.6 10.3 6.5 0.4 0 0.4 0.4 1 6 9 305 0 0 0 0 4.5 0 4.9 4.4 09/19/2004 09:30:00 8 0.7 9.9 6.1 8.2 0.8 9.9 6.5 0.4 0 0.4 0.4 357 6 352 305 0 0 0 0 4.8 0 5.2 4.7 09/19/2004 09:40:00 7.7 0.8 9.5 5.7 8 0.9 9.5 6.1 0.4 0 0.4 0.4 359 5 359 305 0 0 0 0 4.8 0 5.4 4.7 09/19/2004 09:50:00 8.6 0.9 10.7 6.5 8.8 1 11.1 6.8 0.4 0 0.4 0.4 359 4 2 305 0 0 0 0 4.8 0 5.4 4.7 09/19/2004 10:00:00 8.2 0.8 10.7 6.5 8.4 0.8 10.7 6.8 0.4 0 0.4 0.4 358 5 350 305 0 0 0 0 4.7 0 5.2 4.7 09/19/2004 10:10:00 8.3 0.8 9.9 6.5 8.5 0.8 10.3 6.5 0.4 0 0.4 0.4 359 5 4 305 0 0 0 0 4.7 0 5.2 4.7 09/19/2004 10:20:00 8.6 0.7 10.3 6.8 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 1 5 356 305 0 0 0 0 4.6 0 4.9 4.4 09/19/2004 10:30:00 8.1 0.7 9.9 6.1 8.3 0.8 10.3 5.3 0.4 0 0.4 0.4 358 5 1 305 0 0 0 0 4.8 0 5.4 4.4 09/19/2004 10:40:00 8.7 0.7 10.7 6.5 8.9 0.7 10.3 6.8 0.4 0 0.4 0.4 357 5 350 305 0 0 0 0 4.8 0 5.2 4.7 09/19/2004 10:50:00 8.4 0.7 10.3 6.8 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 356 5 353 305 0 0 0 0 4.8 0 5.4 4.7 09/19/2004 11:00:00 8.2 0.7 9.9 6.1 8.5 0.7 9.9 6.1 0.4 0 0.4 0.4 355 5 352 305 0 0 0 0 4.8 0 5.4 4.7 09/19/2004 11:10:00 8.1 0.9 10.3 6.1 8.4 0.9 10.3 6.5 0.4 0 0.4 0.4 359 5 358 305 0 0 0 0 4.8 0 5.4 4.7 09/19/2004 11:20:00 8 0.6 9.9 6.1 8.2 0.7 9.9 6.1 0.4 0 0.4 0.4 1 5 352 305 0 0 0 0 4.9 0.1 5.4 4.7 09/19/2004 11:30:00 7.9 0.5 9.1 6.5 8.1 0.6 9.9 6.5 0.4 0 0.4 0.4 357 6 356 305 0 0 0 0 5.1 0.1 5.6 4.9 09/19/2004 11:40:00 7.6 0.6 9.1 5.7 7.8 0.7 9.5 6.1 0.4 0 0.4 0.4 358 5 357 305 0 0 0 0 4.9 0.1 5.4 4.9 09/19/2004 11:50:00 7.6 0.6 9.1 6.1 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 0 4 0 305 0 0 0 0 4.9 0.1 5.4 4.9 09/19/2004 12:00:00 7.3 0.6 9.1 5.7 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 1 5 359 305 0 0 0 0 5 0.1 5.4 4.9 09/19/2004 12:10:00 7.2 0.6 8.8 5.7 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 357 6 0 305 0 0 0 0 5.2 0 5.6 5.2 09/19/2004 12:20:00 7.5 0.6 9.1 5.7 7.8 0.6 9.1 5.7 0.4 0 0.4 0.4 354 4 357 305 0 0 0 0 5.3 0 5.9 5.2 09/19/2004 12:30:00 7.5 0.5 9.5 6.1 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 0 4 2 305 0 0 0 0 5.4 0.1 5.9 5.2 09/19/2004 12:40:00 7.7 0.5 8.8 5.7 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 0 5 5 305 0 0 0 0 5.5 0.1 5.9 5.4 09/19/2004 12:50:00 7.6 0.6 9.1 5.7 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 359 5 356 305 0 0 0 0 5.5 0.1 5.9 5.4 09/19/2004 13:00:00 7.5 0.6 8.8 5.7 7.8 0.7 9.1 5.7 0.4 0 0.4 0.4 359 6 2 305 0 0 0 0 5.6 0.1 5.9 5.4 09/19/2004 13:10:00 7.7 0.5 8.8 6.1 7.9 0.6 9.1 6.5 0.4 0 0.4 0.4 359 4 1 305 0 0 0 0 5.6 0.1 6.1 5.4 09/19/2004 13:20:00 7.6 0.6 8.8 5.7 7.8 0.7 9.1 5.7 0.4 0 0.4 0.4 0 4 359 305 0 0 0 0 5.6 0.1 6.1 5.4 09/19/2004 13:30:00 7.6 0.6 9.5 6.5 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 359 5 358 305 0 0 0 0 5.6 0.1 6.1 5.4 09/19/2004 13:40:00 7.9 0.6 9.5 6.5 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 0 5 5 305 0 0 0 0 5.9 0 6.4 5.6 09/19/2004 13:50:00 7.8 0.5 9.1 6.5 8 0.6 9.5 6.5 0.4 0 0.4 0.4 1 3 358 305 0 0 0 0 5.7 0 6.1 5.4 09/19/2004 14:00:00 7.8 0.6 9.5 6.1 7.9 0.6 9.5 5.7 0.4 0 0.4 0.4 3 5 3 305 0 0 0 0 5.9 0.1 6.4 5.6 09/19/2004 14:10:00 8 0.5 9.5 6.5 8.1 0.6 9.1 6.1 0.4 0 0.4 0.4 1 6 4 305 0 0 0 0 6.1 0.1 6.7 5.9 09/19/2004 14:20:00 7.8 0.6 9.5 6.5 8 0.6 9.9 6.5 0.4 0 0.4 0.4 2 5 7 305 0 0 0 0 6 0.1 6.7 5.9 09/19/2004 14:30:00 7.6 0.6 9.5 5.7 7.8 0.6 9.9 6.1 0.4 0 0.4 0.4 6 7 2 305 0 0 0 0 6.1 0.1 6.7 5.9 09/19/2004 14:40:00 8 0.5 9.9 6.8 8.1 0.5 9.5 6.5 0.4 0 0.4 0.4 7 5 5 305 0 0 0 0 6 0.1 6.4 5.6 09/19/2004 14:50:00 8 0.6 9.1 6.5 8.1 0.6 9.1 6.5 0.4 0 0.4 0.4 7 5 6 305 0 0 0 0 6 0.1 6.4 5.6 09/19/2004 15:00:00 7.8 0.6 9.5 6.1 8 0.6 9.5 6.5 0.4 0 0.4 0.4 2 6 5 305 0 0 0 0 6 0.1 6.4 5.9 09/19/2004 15:10:00 7.2 0.6 8.8 5.7 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 5 6 359 305 0 0 0 0 6 0 6.4 5.9 09/19/2004 15:20:00 7.5 0.6 9.1 6.1 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 1 6 5 305 0 0 0 0 6.2 0.1 6.7 5.9 09/19/2004 15:30:00 7.4 0.6 9.1 6.1 7.6 0.6 9.5 6.5 0.4 0 0.4 0.4 9 4 14 305 0 0 0 0 6.2 0.2 6.9 5.9 09/19/2004 15:40:00 7.6 0.6 9.1 6.1 7.7 0.7 9.5 5.7 0.4 0 0.4 0.4 8 4 7 305 0 0 0 0 6.1 0.1 6.4 5.9 09/19/2004 15:50:00 7.3 0.6 8.8 5.7 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 7 4 12 305 0 0 0 0 6 0.1 6.4 5.9 09/19/2004 16:00:00 7.2 0.6 8.8 5.3 7.3 0.7 8.4 4.9 0.4 0 0.4 0.4 7 4 4 305 0 0 0 0 6.1 0.1 6.7 5.9 09/19/2004 16:10:00 6.9 0.6 8.4 5.3 7 0.6 8.8 4.9 0.4 0 0.4 0.4 8 4 4 305 0 0 0 0 6 0.1 6.7 5.9 09/19/2004 16:20:00 6.5 0.6 8 5.3 6.6 0.6 8 4.9 0.4 0 0.4 0.4 12 7 2 305 0 0 0 0 6.1 0.1 6.4 5.9 09/19/2004 16:30:00 6.5 0.6 8 4.9 6.6 0.6 8.4 4.6 0.4 0 0.4 0.4 8 6 4 305 0 0 0 0 6.1 0.2 6.7 5.9 09/19/2004 16:40:00 6.3 0.5 7.2 4.6 6.5 0.5 7.6 4.6 0.4 0 0.4 0.4 13 4 12 305 0 0 0 0 6.1 0.1 6.7 5.9 09/19/2004 16:50:00 6.1 0.4 7.2 4.9 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 9 4 5 305 0 0 0 0 6.1 0.1 6.4 5.9 09/19/2004 17:00:00 6.2 0.4 7.6 4.9 6.4 0.5 8 4.9 0.4 0 0.4 0.4 11 4 9 305 0 0 0 0 6 0 6.4 5.9 09/19/2004 17:10:00 5.6 0.4 6.8 4.6 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 11 7 7 305 0 0 0 0 6 0 6.4 5.9 09/19/2004 17:20:00 5.3 0.5 6.5 4.2 5.5 0.5 6.8 4.6 0.4 0 0.4 0.4 9 5 14 305 0 0 0 0 6 0 6.4 5.6 09/19/2004 17:30:00 5 0.5 6.1 3.8 5.2 0.5 6.5 3.8 0.4 0 0.4 0.4 12 5 18 305 0 0 0 0 6 0 6.4 5.9 09/19/2004 17:40:00 4.9 0.3 5.7 4.2 5 0.4 6.1 4.2 0.4 0 0.4 0.4 14 4 9 305 0 0 0 0 6.1 0.1 6.4 5.9 09/19/2004 17:50:00 4.5 0.5 6.1 3.4 4.6 0.5 6.5 3.8 0.4 0 0.4 0.4 15 8 8 305 0 0 0 0 6 0 6.4 5.9 09/19/2004 18:00:00 4.3 0.5 5.3 3 4.5 0.5 5.3 3 0.4 0 0.4 0.4 6 5 13 305 0 0 0 0 6.1 0.1 6.4 5.9 09/19/2004 18:10:00 4 0.6 6.8 3 4.3 0.6 7.6 3.4 0.4 0 0.4 0.4 8 6 5 305 0 0 0 0 6.2 0.1 6.7 5.9 09/19/2004 18:20:00 3.8 0.4 4.9 3 4 0.4 5.3 3 0.4 0 0.4 0.4 6 8 359 305 0 0 0 0 6.4 0 6.9 6.1 09/19/2004 18:30:00 3.4 0.5 4.6 2.3 3.6 0.5 4.6 2.6 0.4 0 0.4 0.4 12 7 12 305 0 0 0 0 6.3 0 6.7 6.1 09/19/2004 18:40:00 3.5 0.4 4.6 2.6 3.7 0.3 4.6 3 0.4 0 0.4 0.4 11 5 8 305 0 0 0 0 6.1 0.1 6.4 5.9 09/19/2004 18:50:00 3.1 0.5 4.2 2.3 3.4 0.5 4.6 2.3 0.4 0 0.4 0.4 359 5 13 305 0 0 0 0 6.2 0.1 6.9 5.9 09/19/2004 19:00:00 2.6 0.4 3.4 1.5 2.8 0.4 3.8 1.9 0.4 0 0.4 0.4 3 9 15 305 0 0 0 0 6 0.1 6.4 5.9 09/19/2004 19:10:00 2.3 0.4 3.4 1.1 2.5 0.4 3.8 1.5 0.4 0 0.4 0.4 3 9 5 305 0 0 0 0 5.8 0 6.4 5.6 09/19/2004 19:20:00 2.4 0.4 3.4 1.5 2.8 0.4 3.8 1.9 0.4 0 0.4 0.4 359 5 355 305 0 0 0 0 5.7 0 6.1 5.6 09/19/2004 19:30:00 1.9 0.4 2.6 0.7 2.3 0.3 3 1.5 0.4 0 0.4 0.4 351 8 338 305 0 0 0 0 5.6 0.1 6.1 5.6 09/19/2004 19:40:00 1.7 0.5 3 0.7 2.1 0.4 3.4 1.5 0.4 0 0.4 0.4 358 7 329 305 0 0 0 0 5.7 0 6.1 5.6 09/19/2004 19:50:00 1 0.5 2.3 0.4 1.5 0.5 2.6 0.4 0.4 0 0.4 0.4 359 7 357 305 0 0 0 0 6 0.1 6.4 5.6 09/19/2004 20:00:00 1.2 0.3 1.9 0.4 1.8 0.3 2.3 1.1 0.4 0 0.4 0.4 5 4 2 305 0 0 0 0 5.7 0.2 6.1 5.4 09/19/2004 20:10:00 0.7 0.4 1.9 0.4 1.2 0.4 2.3 0.4 0.4 0 0.4 0.4 17 2 25 305 0 0 0 0 5.5 0.1 5.9 5.4 09/19/2004 20:20:00 0.4 0.2 1.1 0.4 1.1 0.4 1.9 0.4 0.4 0 0.4 0.4 13 5 16 305 0 0 0 0 5.3 0 5.6 5.2 09/19/2004 20:30:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 5 0 305 305 0 0 0 0 5.2 0 5.6 4.9 09/19/2004 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 1 305 305 0 0 0 0 4.7 0.2 5.4 4.4 09/19/2004 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 0 305 305 0 0 0 0 4.2 0.1 4.7 3.9 09/19/2004 21:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 344 29 305 305 0 0 0 0 4.2 0.2 4.9 3.7 09/19/2004 21:10:00 0.4 0 0.4 0.4 0.9 0.2 1.1 0.4 0.4 0 0.4 0.4 275 0 305 305 0 0 0 0 4.2 0.1 4.9 4.2 09/19/2004 21:20:00 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 275 0 305 305 0 0 0 0 4.1 0.1 4.7 3.7 09/19/2004 21:30:00 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 261 20 305 305 0 0 0 0 3.7 0 4.4 3.4 09/19/2004 21:40:00 0.4 0.1 1.1 0.4 1.2 0.2 1.5 0.7 0.4 0 0.4 0.4 196 13 190 305 0 0 0 0 3.4 0.1 3.9 3.2 09/19/2004 21:50:00 0.6 0.3 1.5 0.4 1.3 0.4 2.3 0.7 0.4 0 0.4 0.4 193 5 199 305 0 0 0 0 3.4 0 3.7 3.2 09/19/2004 22:00:00 1.6 0.3 2.3 1.1 2.2 0.2 2.6 1.9 0.4 0 0.4 0.4 199 0 199 305 0 0 0 0 3.7 0.2 4.2 3.4 09/19/2004 22:10:00 1.9 0.2 2.3 1.5 2.3 0.2 2.6 1.9 0.4 0 0.4 0.4 201 3 199 305 0 0 0 0 4 0 4.2 3.9 09/19/2004 22:20:00 2.1 0.2 2.6 1.5 2.4 0.2 3 1.9 0.4 0 0.4 0.4 206 6 197 305 0 0 0 0 4 0 4.4 3.9 09/19/2004 22:30:00 2.2 0.2 2.6 1.9 2.5 0.2 3 1.9 0.4 0 0.4 0.4 202 2 205 305 0 0 0 0 4.2 0 4.4 4.2 09/19/2004 22:40:00 2.3 0.3 3 1.5 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 196 4 195 305 0 0 0 0 4.2 0 4.4 4.2 09/19/2004 22:50:00 3.2 0.4 4.2 2.3 3.5 0.3 4.6 2.6 0.4 0 0.4 0.4 193 4 194 305 0 0 0 0 4.3 0 4.4 4.2 09/19/2004 23:00:00 3.6 0.3 4.2 3 3.9 0.3 4.6 3.4 0.4 0 0.4 0.4 192 4 196 305 0 0 0 0 4.4 0 4.7 4.4 09/19/2004 23:10:00 4 0.2 4.6 3.4 4.2 0.2 4.6 3.4 0.4 0 0.4 0.4 191 2 187 305 0 0 0 0 4 0 4.4 3.9 09/19/2004 23:20:00 3.7 0.3 4.6 3 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 191 2 189 305 0 0 0 0 4 0 4.4 3.9 09/19/2004 23:30:00 4.1 0.3 4.9 3.4 4.2 0.3 5.3 3.4 0.4 0 0.4 0.4 191 3 190 305 0 0 0 0 4.4 0.1 4.9 4.2 09/19/2004 23:40:00 4.3 0.2 4.9 3.4 4.5 0.3 5.3 3.8 0.4 0 0.4 0.4 191 3 193 305 0 0 0 0 4.6 0 4.7 4.4 09/19/2004 23:50:00 4.2 0.3 4.9 3 4.4 0.3 4.9 3.4 0.4 0 0.4 0.4 188 3 188 305 0 0 0 0 4.2 0 4.4 4.2 09/20/2004 00:00:00 4.6 0.4 5.3 3 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 186 3 187 305 0 0 0 0 4.4 0 4.9 4.2 09/20/2004 00:10:00 4.7 0.4 5.7 3.8 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 186 3 190 305 0 0 0 0 4.2 0 4.4 4.2 09/20/2004 00:20:00 5 0.3 5.7 3.8 5 0.4 5.7 3.8 0.4 0 0.4 0.4 189 2 183 305 0 0 0 0 4.1 0 4.4 4.2 09/20/2004 00:30:00 4.8 0.5 5.7 3.4 5 0.4 5.7 3.8 0.4 0 0.4 0.4 185 3 186 305 0 0 0 0 4.1 0 4.4 3.9 09/20/2004 00:40:00 5.2 0.3 5.7 4.2 5.2 0.4 6.1 4.2 0.4 0 0.4 0.4 191 3 190 305 0 0 0 0 4.4 0.1 4.7 4.2 09/20/2004 00:50:00 4.8 0.5 5.7 3.4 4.9 0.4 5.7 3.8 0.4 0 0.4 0.4 185 3 186 305 0 0 0 0 4.5 0 4.7 4.4 09/20/2004 01:00:00 5.3 0.4 6.1 4.2 5.3 0.4 6.5 4.2 0.4 0 0.4 0.4 190 3 191 305 0 0 0 0 4.7 0 5.2 4.4 09/20/2004 01:10:00 5.6 0.3 6.1 4.6 5.6 0.4 6.5 4.2 0.4 0 0.4 0.4 195 3 197 305 0 0 0 0 5.1 0.2 5.6 4.7 09/20/2004 01:20:00 5.3 0.4 6.5 4.2 5.4 0.4 6.1 4.2 0.4 0 0.4 0.4 191 4 200 305 0 0 0 0 5.3 0.2 5.6 4.9 09/20/2004 01:30:00 5 0.4 5.7 3.4 5.2 0.4 6.1 4.2 0.4 0 0.4 0.4 186 3 192 305 0 0 0 0 5.1 0.2 5.6 4.9 09/20/2004 01:40:00 4.7 0.6 6.5 3 5.1 0.5 6.8 3.8 0.4 0 0.4 0.4 184 5 194 305 0 0 0 0 5.1 0.2 5.6 4.9 09/20/2004 01:50:00 5.4 0.5 7.2 3.4 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 187 5 190 305 0 0 0 0 5 0.2 5.6 4.9 09/20/2004 02:00:00 6 0.3 6.8 4.6 6.1 0.4 7.6 4.2 0.4 0 0.4 0.4 192 3 191 305 0 0 0 0 5.2 0.2 5.9 4.9 09/20/2004 02:10:00 6 0.3 6.8 4.6 6.2 0.4 7.2 5.3 0.4 0 0.4 0.4 193 3 194 305 0 0 0 0 5.3 0 5.9 5.2 09/20/2004 02:20:00 6.2 0.2 6.8 5.7 6.5 0.2 6.8 4.9 0.4 0 0.4 0.4 188 2 189 305 0 0 0 0 5.5 0.1 5.9 5.4 09/20/2004 02:30:00 6.5 0.2 6.8 5.7 6.5 0.3 7.2 5.3 0.4 0 0.4 0.4 189 1 190 305 0 0 0 0 5.5 0.1 6.1 5.4 09/20/2004 02:40:00 6.3 0.3 6.8 5.3 6.1 0.4 6.8 4.6 0.4 0 0.4 0.4 188 2 189 305 0 0 0 0 5.5 0.1 5.9 5.4 09/20/2004 02:50:00 6.1 0.3 6.8 4.6 6 0.4 6.8 4.2 0.4 0 0.4 0.4 188 2 186 305 0 0 0 0 5.6 0.2 6.1 5.4 09/20/2004 03:00:00 6.6 0.2 7.2 6.1 6.8 0.3 7.2 5.7 0.4 0 0.4 0.4 190 1 192 305 0 0 0 0 5.7 0 6.1 5.6 09/20/2004 03:10:00 6.5 0.2 6.8 5.7 6.6 0.3 7.2 5.3 0.4 0 0.4 0.4 193 2 192 305 0 0 0 0 5.6 0 6.1 5.6 09/20/2004 03:20:00 6.3 0.2 6.8 5.7 6.4 0.3 6.8 5.3 0.4 0 0.4 0.4 192 1 192 305 0 0 0 0 5.5 0.1 5.9 5.4 09/20/2004 03:30:00 6.2 0.3 7.2 5.3 6.3 0.3 7.2 4.9 0.4 0 0.4 0.4 192 3 195 305 0 0 0 0 5.4 0 5.9 5.2 09/20/2004 03:40:00 5.7 0.5 7.2 4.2 6 0.4 7.6 4.6 0.4 0 0.4 0.4 191 4 184 305 0 0 0 0 5.1 0 5.6 4.9 09/20/2004 03:50:00 5.8 0.4 6.8 4.9 5.9 0.4 6.8 4.6 0.4 0 0.4 0.4 190 3 196 305 0 0 0 0 5.1 0.1 5.6 4.9 09/20/2004 04:00:00 5.6 0.4 6.8 4.6 5.7 0.4 6.8 4.6 0.4 0 0.4 0.4 189 4 192 305 0 0 0 0 5.2 0 5.6 4.9 09/20/2004 04:10:00 5.5 0.4 6.5 4.6 5.7 0.4 6.8 4.6 0.4 0 0.4 0.4 188 3 186 305 0 0 0 0 5.1 0 5.6 4.9 09/20/2004 04:20:00 5.4 0.6 6.5 3 5.5 0.5 6.5 3.8 0.4 0 0.4 0.4 185 4 185 305 0 0 0 0 5.1 0 5.4 4.9 09/20/2004 04:30:00 5.1 0.8 6.8 2.3 5.7 0.6 7.6 4.2 0.4 0 0.4 0.4 181 5 186 305 0 0 0 0 5.2 0 5.6 5.2 09/20/2004 04:40:00 4 0.9 6.1 2.3 5.5 0.6 6.8 3.4 0.4 0 0.4 0.4 175 6 180 305 0 0 0 0 5.2 0 5.6 5.2 09/20/2004 04:50:00 3.9 0.7 5.7 2.3 5.7 0.6 6.8 4.2 0.4 0 0.4 0.4 171 5 181 305 0 0 0 0 5.1 0.1 5.6 4.9 09/20/2004 05:00:00 5.8 1 8 3.4 6.4 0.5 7.6 4.6 0.4 0 0.4 0.4 159 6 154 305 0 0 0 0 4.8 0 5.4 4.9 09/20/2004 05:10:00 7.5 0.5 8.8 6.1 7.2 0.5 8.8 5.7 0.4 0 0.4 0.4 150 4 154 305 0 0 0 0 4.8 0 5.2 4.9 09/20/2004 05:20:00 7.3 0.8 9.1 5.3 7 0.7 8.8 4.9 0.4 0 0.4 0.4 148 6 152 305 0 0 0 0 4.8 0 4.9 4.7 09/20/2004 05:30:00 8 0.8 9.5 5.7 7.7 0.7 9.1 5.7 0.4 0 0.4 0.4 150 5 149 305 0 0 0 0 4.7 0 5.2 4.7 09/20/2004 05:40:00 8.6 0.7 10.3 6.5 8.2 0.7 10.3 6.5 0.4 0 0.4 0.4 148 5 146 305 0 0 0 0 4.8 0.1 5.4 4.7 09/20/2004 05:50:00 8.3 1 10.7 5.3 8.1 0.9 9.9 6.1 0.4 0 0.4 0.4 141 7 145 305 0 0 0 0 4.9 0.1 5.4 4.7 09/20/2004 06:00:00 9.2 0.8 11.1 6.8 9 0.9 11.1 6.5 0.4 0 0.4 0.4 138 5 147 305 0 0 0 0 5 0.2 5.4 4.9 09/20/2004 06:10:00 9.4 0.7 10.7 7.2 9.2 0.7 10.7 7.6 0.4 0 0.4 0.4 135 5 137 305 0 0 0 0 4.9 0.1 5.4 4.7 09/20/2004 06:20:00 9.9 0.6 11.1 8 9.6 0.6 11.1 7.6 0.4 0 0.4 0.4 135 4 136 305 0 0 0 0 4.9 0.1 5.4 4.7 09/20/2004 06:30:00 10.2 0.7 12.2 8 9.9 0.7 11.5 7.6 0.4 0 0.4 0.4 135 4 139 305 0 0 0 0 4.9 0.1 5.4 4.7 09/20/2004 06:40:00 10.3 0.8 12.2 8 10.1 0.8 11.8 7.2 0.4 0 0.4 0.4 138 5 147 305 0 0 0 0 4.9 0.1 5.4 4.7 09/20/2004 06:50:00 10.5 0.7 12.2 8.4 10.2 0.7 11.8 8.4 0.4 0 0.4 0.4 138 4 139 305 0 0 0 0 4.9 0.1 5.4 4.7 09/20/2004 07:00:00 10.4 0.7 11.8 8 10.1 0.7 11.8 8.4 0.4 0 0.4 0.4 136 4 137 305 0 0 0 0 5 0.2 5.4 4.9 09/20/2004 07:10:00 10.5 0.7 11.8 8.4 10.2 0.6 11.8 8.4 0.4 0 0.4 0.4 134 4 137 305 4 3 8 0 4.9 0.1 5.4 4.9 09/20/2004 07:20:00 10.6 0.9 12.6 8 10.4 0.9 12.6 8 0.4 0 0.4 0.4 136 4 133 305 13 9 25 0 5 0.2 5.4 4.9 09/20/2004 07:30:00 10.6 1 12.6 7.6 10.4 0.9 12.6 8 2.8 4.3 12.6 0.4 137 6 145 305 24 4 25 0 5 0.1 5.4 4.9 09/20/2004 07:40:00 10.6 1.1 13 8.4 10.4 1 12.6 7.6 1.4 3.2 12.6 0.4 139 7 143 305 23 6 27 0 4.9 0.1 5.4 4.9 09/20/2004 07:50:00 11.1 1 13.7 8 10.9 1.1 13.7 7.6 1.2 2.5 12.2 0.4 140 6 149 305 39 23 17 0 4.9 0.1 5.4 4.9 09/20/2004 08:00:00 10.5 1.1 14.1 7.2 10.5 1 13.3 8 1.8 3.3 11.8 0.4 139 6 145 305 29 16 21 0 4.9 0.1 5.4 4.7 09/20/2004 08:10:00 10.8 0.9 13 8.4 10.6 0.9 12.6 8.4 1.9 3.6 12.6 0.4 138 5 144 305 29 18 19 0 4.8 0 5.4 4.7 09/20/2004 08:20:00 11.1 0.8 13 8.8 10.9 0.8 13 9.1 2.3 4 12.6 0.4 136 5 147 305 25 12 19 0 4.8 0 5.4 4.7 09/20/2004 08:30:00 11.6 1 13.7 8.4 11.4 1 13.7 8.8 1.3 2.6 11.8 0.4 135 5 136 305 27 14 18 0 4.8 0 5.4 4.7 09/20/2004 08:40:00 12.2 0.8 14.1 9.5 12.1 0.9 14.1 9.9 0.7 1.6 13.7 0.4 137 5 143 305 33 22 33 0 4.8 0 5.4 4.7 09/20/2004 08:50:00 12.2 1 14.5 9.1 12 1 14.1 9.5 0.6 1.3 11.8 0.4 137 5 138 305 33 18 20 0 4.8 0 5.2 4.7 09/20/2004 09:00:00 11.9 1.1 14.1 8.4 11.7 1 13.7 8.4 4.8 5.4 13.7 0.4 137 5 147 305 30 19 20 0 4.7 0 4.9 4.4 09/20/2004 09:10:00 12.8 0.7 14.1 10.7 12.6 0.7 14.1 10.3 0.5 0.9 10.3 0.4 135 3 138 305 32 23 21 0 4.5 0.1 4.9 4.4 09/20/2004 09:20:00 12.5 0.9 14.5 9.9 12.2 0.8 14.1 9.9 0.4 0.2 3 0.4 135 4 133 305 36 21 21 0 4.5 0.1 4.9 4.4 09/20/2004 09:30:00 12.1 1.1 15.3 8.8 11.9 1.2 14.5 9.1 0.5 1.2 13.3 0.4 137 5 144 305 55 32 103 0 4.5 0.1 4.9 4.4 09/20/2004 09:40:00 11.8 1.2 14.9 8 11.6 1.1 14.9 7.6 1.9 3.5 11.8 0.4 137 5 129 305 48 35 60 0 4.5 0.1 4.9 4.4 09/20/2004 09:50:00 11.8 0.7 13.7 9.5 11.6 0.7 13.3 9.5 0.4 0.1 0.7 0.4 134 4 140 305 34 20 38 0 4.4 0.1 4.9 4.4 09/20/2004 10:00:00 12.1 0.7 13.7 9.9 11.9 0.7 13.3 9.5 0.4 0 0.7 0.4 133 3 130 305 30 15 24 0 4.4 0.1 4.7 4.2 09/20/2004 10:10:00 11.8 0.7 13.3 9.5 11.5 0.7 13 9.9 0.4 0 0.7 0.4 132 3 140 305 27 20 21 0 4.4 0 4.9 4.4 09/20/2004 10:20:00 12 1 13.3 8.8 11.8 0.9 13.7 9.1 0.4 0 0.7 0.4 131 3 132 305 56 23 76 0 4.3 0 4.7 4.2 09/20/2004 10:30:00 11.6 0.6 13 9.5 11.4 0.7 13 9.1 0.4 0 0.7 0.4 129 3 125 305 24 11 15 0 4.2 0 4.7 4.2 09/20/2004 10:40:00 11 0.9 12.6 8.4 10.9 0.8 12.6 7.6 0.4 0 0.7 0.4 129 4 129 305 26 15 21 0 4.3 0 4.7 4.2 09/20/2004 10:50:00 10.9 0.8 12.6 8.4 10.7 0.7 12.2 8.4 0.4 0 0.4 0.4 126 5 120 305 26 15 14 0 4.3 0 4.7 4.2 09/20/2004 11:00:00 10.9 0.9 12.6 7.6 10.8 0.8 12.6 8 0.4 0.6 9.9 0.4 128 4 124 305 32 12 32 0 4.3 0 4.9 4.2 09/20/2004 11:10:00 10.2 0.7 11.8 7.6 10.1 0.7 11.8 7.2 0.4 0.1 1.5 0.4 130 5 131 305 24 14 46 0 4.3 0 4.9 4.2 09/20/2004 11:20:00 10.2 0.9 12.2 7.2 10 1 11.5 7.2 0.4 0 0.4 0.4 127 8 131 305 45 24 87 0 4.4 0 4.9 4.4 09/20/2004 11:30:00 11 0.5 12.2 9.1 10.8 0.6 12.2 9.1 0.4 0 0.4 0.4 131 3 129 305 19 3 22 0 4.4 0 4.7 4.4 09/20/2004 11:40:00 9.7 1 12.6 6.8 9.7 1 12.2 6.8 0.4 0 0.4 0.4 127 7 118 305 18 0 18 0 4.4 0 4.9 4.2 09/20/2004 11:50:00 10.3 1 12.2 7.2 10.2 1 11.8 7.2 0.4 0 0.4 0.4 127 5 122 305 18 0 18 0 4.5 0.1 4.9 4.4 09/20/2004 12:00:00 10.1 1 12.6 7.2 10.1 1 12.6 6.8 0.4 0 0.4 0.4 125 7 134 305 18 0 18 0 4.7 0 5.2 4.7 09/20/2004 12:10:00 10.5 0.7 12.2 8 10.4 0.7 12.2 8.8 0.4 0 0.4 0.4 129 5 127 305 18 0 18 0 4.7 0 4.9 4.7 09/20/2004 12:20:00 10.1 0.6 11.5 8.4 9.9 0.7 11.5 8.4 0.4 0 0.4 0.4 130 5 133 305 18 0 18 0 4.8 0 5.2 4.7 09/20/2004 12:30:00 9.4 0.8 11.5 6.8 9.3 0.8 11.1 6.8 0.5 1 8.8 0.4 125 6 124 305 25 16 65 0 4.9 0.1 5.4 4.7 09/20/2004 12:40:00 9.1 0.8 11.1 6.8 9.1 0.8 11.1 6.5 0.4 0 0.4 0.4 124 7 118 305 26 6 29 0 5.2 0 5.6 4.9 09/20/2004 12:50:00 9.3 0.9 12.2 6.5 9.3 0.9 12.6 6.5 0.4 0 0.4 0.4 119 7 148 305 30 1 33 0 5.3 0 5.6 5.2 09/20/2004 13:00:00 9.1 1.2 12.2 6.5 9 1.2 12.6 5.7 0.4 0 0.4 0.4 119 9 106 305 31 1 31 0 5.4 0 5.9 5.2 09/20/2004 13:10:00 9.7 1 13 6.5 9.6 1 13 6.8 0.7 1.7 11.8 0.4 113 8 108 305 31 2 31 0 5.2 0.1 5.6 4.9 09/20/2004 13:20:00 10.2 1 12.2 7.2 9.9 1 12.2 7.6 0.9 2.4 11.8 0.4 108 7 113 305 22 8 20 0 4.9 0.1 5.4 4.9 09/20/2004 13:30:00 10.4 1.1 12.6 7.2 10.1 1 13 7.2 0.4 0 0.4 0.4 107 7 109 305 20 1 20 0 5 0.1 5.4 4.9 09/20/2004 13:40:00 10.5 1.1 13.3 6.8 10.3 1 12.6 7.6 0.4 0 0.7 0.4 109 7 118 305 28 19 20 0 5.2 0 5.6 4.9 09/20/2004 13:50:00 10.3 1.2 12.6 6.8 10.2 1.1 13.3 6.8 0.4 0 0.4 0.4 108 8 106 305 33 18 25 0 5.4 0 5.6 5.2 09/20/2004 14:00:00 10 1.2 13.3 6.5 9.7 1.3 12.6 6.8 0.4 0.6 10.7 0.4 106 9 103 305 43 22 38 0 5.5 0 5.9 5.4 09/20/2004 14:10:00 8.8 1.5 12.6 5.3 8.5 1.5 13 5.3 0.4 0 0.7 0.4 105 11 99 305 32 10 46 0 5.5 0 5.9 5.4 09/20/2004 14:20:00 8.4 1.3 12.2 5.3 8.3 1.4 13.7 5.3 0.4 0.1 1.9 0.4 108 13 100 305 33 15 36 0 5.5 0 5.9 5.4 09/20/2004 14:30:00 8.2 1.3 12.2 4.6 8.1 1.4 12.6 4.6 0.4 0 0.7 0.4 97 18 67 305 27 12 26 0 5.5 0 5.9 5.4 09/20/2004 14:40:00 10.1 1.7 14.9 5.7 9.9 1.7 15.3 4.9 0.5 0.9 11.1 0.4 78 12 65 305 34 18 19 0 5.3 0 5.6 5.2 09/20/2004 14:50:00 10.9 1.3 14.9 7.6 10.7 1.3 14.5 7.6 0.8 1.9 11.8 0.4 82 9 77 305 41 22 34 0 5.2 0.1 5.4 4.9 09/20/2004 15:00:00 11.8 1.1 14.9 7.6 11.5 1.2 14.5 7.2 1.2 2.9 13.7 0.4 81 8 67 305 39 18 57 0 5.1 0.1 5.4 4.9 09/20/2004 15:10:00 12.5 1.2 15.3 8.8 12.1 1.3 14.9 6.5 1.3 3.1 13.7 0.4 83 7 90 305 53 17 22 0 5 0.1 5.4 4.9 09/20/2004 15:20:00 13 1 16.1 8.8 12.7 1.2 16.4 8.4 1.3 3.2 13.3 0.4 80 6 77 305 43 21 28 0 5 0.1 5.4 4.7 09/20/2004 15:30:00 13.2 1.2 16.8 9.1 12.6 1.2 15.3 7.6 0.4 0.7 10.3 0.4 81 7 94 305 59 22 45 0 5 0.1 5.4 4.9 09/20/2004 15:40:00 13.6 1.3 16.4 8.8 13.1 1.3 16.8 9.1 0.4 0.2 3 0.4 80 7 85 305 66 13 68 0 5 0.1 5.4 4.9 09/20/2004 15:50:00 13.3 1.2 17.2 8.4 12.8 1.2 16.8 8.4 5.6 6.1 16.8 0.4 80 6 80 305 50 19 25 0 5 0.1 5.4 4.7 09/20/2004 16:00:00 13.1 1.5 16.8 8.8 12.8 1.5 16.4 8.8 0.4 0.1 0.7 0.4 79 6 75 305 49 15 49 0 5 0.1 5.4 4.9 09/20/2004 16:10:00 13.5 1.2 16.1 9.9 13.1 1.2 16.1 9.5 5.3 6.1 14.9 0.4 78 6 82 305 47 15 29 0 4.9 0.1 5.4 4.9 09/20/2004 16:20:00 13.5 1.1 15.6 10.7 13.1 1.1 15.6 9.9 0.4 0.1 1.5 0.4 76 6 77 305 50 9 40 0 4.9 0 5.4 4.7 09/20/2004 16:30:00 13.4 1.2 16.4 10.3 13 1.2 15.6 9.9 0.4 0 0.7 0.4 75 5 77 305 55 4 56 0 4.9 0 5.2 4.7 09/20/2004 16:40:00 13.4 1.1 16.4 9.9 13 1 15.3 9.5 0.4 0 0.7 0.4 77 5 82 305 44 16 74 0 4.8 0 5.2 4.7 09/20/2004 16:50:00 13.3 1 16.1 9.5 12.8 1 14.9 9.5 0.4 0 0.4 0.4 75 6 75 305 54 18 33 0 4.8 0 5.2 4.7 09/20/2004 17:00:00 13.8 0.8 15.3 11.1 13.4 0.9 15.3 10.3 0.4 0 0.7 0.4 72 4 73 305 59 13 54 0 4.7 0 5.4 4.4 09/20/2004 17:10:00 14.2 1 16.1 10.7 13.8 1.1 16.1 10.7 0.4 0.1 0.7 0.4 71 5 69 305 49 8 50 0 4.5 0.1 4.9 4.4 09/20/2004 17:20:00 14.1 0.8 16.4 11.5 13.7 0.9 16.1 10.7 0.4 0 0.7 0.4 72 4 70 305 61 20 41 0 4.5 0.1 4.9 4.4 09/20/2004 17:30:00 14.1 0.6 16.1 12.2 13.7 0.7 15.3 11.5 0.4 0 0.7 0.4 70 4 67 305 53 15 51 0 4.5 0.1 4.9 4.4 09/20/2004 17:40:00 13.9 0.9 16.4 11.5 13.4 1 15.6 10.7 0.4 0 0.7 0.4 66 5 66 305 54 16 52 0 4.5 0.1 4.9 4.4 09/20/2004 17:50:00 14.7 0.9 16.8 12.6 14.3 0.9 16.4 12.2 0.4 0 0.4 0.4 64 4 59 305 53 19 49 0 4.3 0 4.7 4.2 09/20/2004 18:00:00 14.9 0.8 16.8 12.2 14.5 0.9 16.8 11.5 0.4 0 0.7 0.4 65 5 61 305 57 23 77 0 4.1 0.1 4.4 3.9 09/20/2004 18:10:00 14.8 0.8 17.2 12.6 14.4 0.8 17.2 12.2 0.4 0 0.4 0.4 64 5 62 305 61 8 58 0 4 0.1 4.4 3.7 09/20/2004 18:20:00 14.2 1 16.4 11.1 13.9 1 16.1 11.1 0.4 0 0.4 0.4 64 5 70 305 37 10 31 0 4 0.1 4.4 3.7 09/20/2004 18:30:00 15 1 17.2 12.2 14.6 1.1 17.2 11.5 0.4 0 0.4 0.4 62 5 65 305 68 27 86 0 4 0.1 4.4 3.7 09/20/2004 18:40:00 14.8 1.1 17.6 11.1 14.4 1.2 17.2 9.9 0.4 0 0.4 0.4 61 5 53 305 101 1 99 0 4 0.1 4.4 3.7 09/20/2004 18:50:00 15.2 0.8 17.2 13 14.8 0.9 16.8 12.6 0.4 0 0.7 0.4 62 5 63 305 101 1 101 0 4 0.1 4.4 3.7 09/20/2004 19:00:00 15.5 0.8 17.6 12.6 15.1 0.9 17.2 12.6 0.4 0 0.4 0.4 64 4 67 305 68 33 34 0 4 0.1 4.4 3.7 09/20/2004 19:10:00 15 1.1 17.6 12.2 14.5 1.1 16.8 11.8 0.4 0 0.4 0.4 64 4 72 305 35 1 33 0 4 0 4.4 3.7 09/20/2004 19:20:00 14.6 1.2 17.6 11.8 14 1.2 17.2 11.1 0.4 0 0.4 0.4 61 5 62 305 33 1 32 0 4.2 0 4.7 4.2 09/20/2004 19:30:00 14.7 1 17.2 11.8 14.2 1.1 16.8 11.1 0.4 0 0.4 0.4 63 4 62 305 29 1 29 0 4.2 0 4.7 4.2 09/20/2004 19:40:00 13.8 1.1 16.1 10.3 13.4 1.1 15.6 9.9 0.4 0 0.4 0.4 63 4 68 305 27 0 28 0 4.2 0 4.7 4.2 09/20/2004 19:50:00 12.8 1.3 16.1 9.1 12.4 1.3 15.3 8.8 0.4 0 0.4 0.4 61 6 56 305 29 5 28 0 4.4 0 4.7 4.2 09/20/2004 20:00:00 14.6 1.2 16.8 9.9 14.3 1.2 16.8 9.5 0.4 0 0.4 0.4 56 5 57 305 28 1 28 0 4.3 0 4.7 4.2 09/20/2004 20:10:00 14.7 0.8 17.2 12.2 14.3 1 16.8 11.8 0.4 0 0.4 0.4 56 4 54 305 26 0 26 0 4.2 0 4.7 4.2 09/20/2004 20:20:00 13.7 0.9 16.1 11.1 13.3 0.9 15.6 9.9 0.4 0 0.4 0.4 58 7 49 305 24 0 25 0 4.2 0 4.7 3.9 09/20/2004 20:30:00 13.3 1.3 17.2 9.9 13 1.3 16.4 9.5 0.4 0 0.4 0.4 52 6 62 305 24 0 24 0 4.1 0.1 4.7 3.9 09/20/2004 20:40:00 12.8 0.8 14.9 10.7 12.6 0.8 14.5 9.9 0.4 0 0.4 0.4 49 4 50 305 23 0 23 0 4 0.1 4.4 3.7 09/20/2004 20:50:00 12.6 1.2 15.3 9.5 12.4 1.2 14.9 9.5 0.4 0 0.4 0.4 48 4 40 305 22 0 22 0 4.2 0 4.7 3.9 09/20/2004 21:00:00 13.9 1.6 18.7 10.3 13.6 1.7 18.7 10.3 0.4 0 0.4 0.4 45 5 44 305 22 0 21 0 4 0.1 4.4 3.7 09/20/2004 21:10:00 15.8 1.1 18.3 12.2 15.6 1.1 18.3 12.6 0.4 0 0.4 0.4 42 5 47 305 66 39 97 0 3.8 0 4.4 3.7 09/20/2004 21:20:00 15.3 1.1 17.9 12.2 15 1.2 17.6 11.5 0.4 0 0.4 0.4 43 5 46 305 102 1 103 0 3.9 0.1 4.4 3.7 09/20/2004 21:30:00 14.8 1.3 17.6 11.1 14.7 1.4 18.3 11.1 0.4 0 0.4 0.4 41 5 37 305 86 11 100 0 3.8 0.1 4.4 3.7 09/20/2004 21:40:00 15.4 1.1 17.6 11.5 15.2 1.1 17.2 11.5 0.4 0 0.4 0.4 41 4 39 305 77 0 77 0 3.8 0 4.4 3.4 09/20/2004 21:50:00 15.5 1.1 17.6 10.7 15.2 1.1 17.2 11.1 0.4 0 0.4 0.4 44 5 45 305 76 0 76 0 3.8 0 4.2 3.4 09/20/2004 22:00:00 14.5 1.4 17.6 11.1 14.2 1.4 17.2 10.7 0.4 0 0.4 0.4 41 5 43 305 75 0 74 0 4 0.1 4.4 3.7 09/20/2004 22:10:00 14.9 1.3 17.9 11.8 14.7 1.3 17.9 11.5 0.4 0 0.4 0.4 41 7 35 305 74 0 74 0 4.2 0 4.7 4.2 09/20/2004 22:20:00 13.9 1.2 17.6 11.1 13.7 1.3 17.9 10.7 0.4 0 0.4 0.4 45 7 44 305 74 0 74 0 4.3 0.1 4.9 4.2 09/20/2004 22:30:00 14.3 1.5 17.2 10.7 14 1.7 17.2 9.9 0.4 0 0.4 0.4 45 5 44 305 73 0 74 0 4.3 0.1 4.9 4.2 09/20/2004 22:40:00 13.8 1 16.1 11.1 13.5 1.1 16.1 10.3 0.4 0 0.4 0.4 42 6 49 305 73 0 73 0 4.5 0.1 4.9 4.2 09/20/2004 22:50:00 13.4 0.8 15.6 11.5 13.2 0.9 15.3 10.3 0.4 0 0.4 0.4 38 4 40 305 73 0 73 0 4.8 0.1 5.4 4.7 09/20/2004 23:00:00 13.7 0.9 15.6 10.7 13.6 1 15.6 10.3 0.4 0 0.4 0.4 36 4 41 305 72 0 72 0 4.9 0 5.4 4.7 09/20/2004 23:10:00 13.2 1 15.3 10.3 13.1 1 15.3 10.3 0.4 0 0.4 0.4 39 5 32 305 72 0 72 0 4.8 0 5.4 4.7 09/20/2004 23:20:00 13 1 15.3 9.9 12.9 1 15.3 9.9 0.4 0 0.4 0.4 36 6 27 305 71 0 72 0 4.8 0 5.2 4.7 09/20/2004 23:30:00 13.8 0.6 15.3 11.5 13.7 0.7 15.3 11.5 0.4 0 0.4 0.4 34 3 35 305 71 0 71 0 4.6 0 4.9 4.4 09/20/2004 23:40:00 13.4 0.8 15.3 11.1 13.3 0.8 15.3 9.5 0.4 0 0.4 0.4 40 4 46 305 71 0 71 0 4.5 0.1 4.9 4.4 09/20/2004 23:50:00 13 0.8 14.9 10.7 12.8 0.9 14.9 10.7 0.4 0 0.4 0.4 34 5 33 305 71 0 71 0 4.5 0.1 4.9 4.4 09/21/2004 00:00:00 13 0.8 14.5 10.7 12.9 0.9 14.5 9.9 0.4 0 0.4 0.4 38 4 41 305 70 0 70 0 4.5 0.2 4.9 4.4 09/21/2004 00:10:00 12.6 1 14.5 9.5 12.5 1.1 14.5 9.1 0.4 0 0.4 0.4 33 4 34 305 70 0 70 0 4.6 0.1 4.9 4.4 09/21/2004 00:20:00 12.8 0.9 14.5 9.9 12.7 0.9 14.5 9.5 0.4 0 0.4 0.4 35 4 35 305 70 0 70 0 4.6 0.1 4.9 4.4 09/21/2004 00:30:00 13.1 0.8 14.9 10.7 13 0.9 15.3 9.5 0.4 0 0.4 0.4 35 4 36 305 69 0 69 0 4.6 0.1 4.9 4.4 09/21/2004 00:40:00 13.6 0.8 15.3 10.7 13.5 0.9 15.6 10.3 0.4 0 0.4 0.4 32 4 30 305 70 0 70 0 4.7 0 4.9 4.4 09/21/2004 00:50:00 13.4 1 15.3 10.3 13.4 1 15.3 9.9 0.4 0 0.4 0.4 31 5 29 305 70 0 70 0 4.7 0.1 5.2 4.4 09/21/2004 01:00:00 12.4 1 14.5 9.5 12.3 1 14.5 9.5 0.4 0 0.4 0.4 31 6 32 305 69 0 69 0 4.7 0 5.2 4.4 09/21/2004 01:10:00 13.3 1 15.6 10.3 13.2 1.1 15.6 10.7 0.4 0 0.4 0.4 28 5 32 305 69 0 69 0 4.7 0 5.2 4.4 09/21/2004 01:20:00 13.4 0.8 14.9 10.7 13.4 0.8 14.9 10.3 0.4 0 0.4 0.4 25 4 22 305 68 0 69 0 4.7 0.1 5.2 4.4 09/21/2004 01:30:00 13.4 1 15.6 10.3 13.4 1.1 15.6 10.7 0.4 0 0.4 0.4 22 4 31 305 68 0 68 0 4.6 0.1 4.9 4.4 09/21/2004 01:40:00 13.1 1.1 15.6 9.9 13 1.1 15.6 9.9 0.4 0 0.4 0.4 26 3 23 305 68 0 69 0 4.6 0.1 4.9 4.4 09/21/2004 01:50:00 13.3 0.8 15.3 11.1 13.3 0.8 15.3 10.7 0.4 0 0.4 0.4 26 4 26 305 67 0 67 0 4.5 0.1 4.9 4.4 09/21/2004 02:00:00 13.3 0.8 15.3 11.1 13.2 0.9 15.3 10.3 0.4 0 0.4 0.4 30 5 31 305 66 0 66 0 4.5 0.1 4.9 4.4 09/21/2004 02:10:00 13.1 0.8 15.3 10.7 13 0.9 15.3 10.7 0.4 0 0.4 0.4 29 5 30 305 65 0 64 0 4.5 0.1 4.9 4.4 09/21/2004 02:20:00 13.6 0.8 15.6 10.7 13.5 0.8 15.6 11.1 0.4 0 0.4 0.4 29 4 28 305 59 11 63 0 4.6 0 4.9 4.4 09/21/2004 02:30:00 13.8 1 15.6 10.7 13.7 1 16.1 11.1 0.4 0 0.4 0.4 29 4 31 305 34 0 33 0 4.6 0 4.9 4.4 09/21/2004 02:40:00 14 0.8 16.4 11.5 13.9 0.9 16.1 11.5 0.4 0 0.4 0.4 24 4 28 305 34 0 34 0 4.5 0.1 4.9 4.4 09/21/2004 02:50:00 14 0.8 15.6 11.5 13.9 0.9 15.6 11.5 0.4 0 0.4 0.4 24 6 18 305 34 0 34 0 4.5 0.1 4.9 4.4 09/21/2004 03:00:00 14.2 0.8 15.6 11.5 14.1 1 16.4 11.1 0.4 0 0.4 0.4 25 5 19 305 35 0 35 0 4.5 0.1 4.9 4.4 09/21/2004 03:10:00 13.9 0.8 15.6 11.1 13.8 0.9 16.1 11.1 0.4 0 0.4 0.4 25 5 22 305 35 0 35 0 4.5 0.1 4.9 4.4 09/21/2004 03:20:00 14.2 0.8 16.1 11.8 14.1 0.8 15.6 11.5 0.4 0 0.4 0.4 23 5 22 305 35 0 35 0 4.4 0.1 4.9 4.4 09/21/2004 03:30:00 13.9 0.8 16.4 11.1 13.9 0.9 16.4 10.7 0.4 0 0.4 0.4 22 3 29 305 36 0 35 0 4.5 0.1 4.9 4.4 09/21/2004 03:40:00 13.7 1 16.1 9.9 13.7 1 16.1 9.9 0.4 0 0.4 0.4 23 5 23 305 36 0 36 0 4.4 0.1 4.9 4.4 09/21/2004 03:50:00 13.9 1 16.1 11.1 13.9 1.1 16.4 11.1 0.4 0 0.4 0.4 21 4 23 305 35 0 35 0 4.5 0.1 4.9 4.4 09/21/2004 04:00:00 14.3 0.9 16.4 12.2 14.3 1 16.4 11.1 0.4 0 0.4 0.4 25 4 20 305 34 0 34 0 4.4 0 4.7 4.2 09/21/2004 04:10:00 14.5 0.8 16.1 12.2 14.5 1 16.4 10.7 0.4 0 0.4 0.4 21 4 27 305 33 0 33 0 4.2 0 4.7 4.2 09/21/2004 04:20:00 13.5 1 15.6 9.9 13.4 1.2 16.1 9.5 0.4 0 0.4 0.4 21 5 11 305 32 0 32 0 4.4 0 4.7 4.2 09/21/2004 04:30:00 13.9 1.1 16.8 11.5 13.9 1.2 16.8 10.7 0.4 0 0.4 0.4 20 4 20 305 32 0 32 0 4.4 0.1 4.7 4.2 09/21/2004 04:40:00 14 0.9 16.1 11.1 14.1 1 16.4 10.7 0.4 0 0.4 0.4 17 4 10 305 30 1 29 0 4.3 0.1 4.7 4.2 09/21/2004 04:50:00 14.4 0.9 16.1 11.8 14.5 1 16.4 11.8 0.4 0 0.4 0.4 16 4 9 305 29 0 29 0 4.3 0 4.7 4.2 09/21/2004 05:00:00 14 1 16.1 10.7 14 1.1 16.1 10.7 0.4 0 0.4 0.4 22 4 23 305 28 0 29 0 4.3 0 4.7 4.2 09/21/2004 05:10:00 14.1 0.8 16.1 11.5 14 0.9 16.1 11.1 0.4 0 0.4 0.4 24 5 24 305 28 0 28 0 4.3 0 4.7 4.2 09/21/2004 05:20:00 14.2 0.9 16.4 11.8 14.1 1 16.4 11.8 0.4 0 0.4 0.4 19 5 16 305 29 0 29 0 4.4 0 4.7 4.2 09/21/2004 05:30:00 14.7 0.8 16.8 13 14.7 0.9 16.8 12.2 0.4 0 0.4 0.4 18 4 17 305 28 0 28 0 4.4 0 4.7 4.2 09/21/2004 05:40:00 15.1 1 17.2 12.6 15.1 1 17.6 11.8 0.4 0 0.4 0.4 19 4 17 305 28 0 28 0 4.3 0 4.7 4.2 09/21/2004 05:50:00 15.1 1.1 17.2 11.8 15 1.2 17.6 11.1 0.4 0 0.4 0.4 20 5 17 305 25 2 28 0 4.3 0 4.7 4.2 09/21/2004 06:00:00 15.4 0.9 17.6 13 15.3 1 17.9 11.8 0.4 0 0.4 0.4 17 4 20 305 25 0 25 0 4.4 0 4.7 4.2 09/21/2004 06:10:00 15.4 1 17.2 12.2 15.3 1.1 17.6 12.2 0.4 0 0.4 0.4 19 5 26 305 27 1 27 0 4.4 0 4.7 4.2 09/21/2004 06:20:00 15.1 1 17.2 13 15 1 17.6 11.5 0.4 0 0.4 0.4 20 5 19 305 29 0 28 0 4.3 0 4.7 4.2 09/21/2004 06:30:00 14.9 1 16.8 11.8 14.8 1 17.2 11.8 0.4 0 0.4 0.4 20 5 17 305 29 0 28 0 4.3 0 4.7 4.2 09/21/2004 06:40:00 14.8 1 17.2 11.8 14.7 1.2 17.2 11.5 0.4 0 0.4 0.4 16 4 14 305 28 0 28 0 4.2 0 4.7 4.2 09/21/2004 06:50:00 15.6 1 17.9 12.6 15.6 1 18.3 12.6 0.4 0 0.4 0.4 17 5 9 305 29 0 28 0 4.2 0 4.7 3.9 09/21/2004 07:00:00 15.2 1.1 17.2 11.8 15.1 1.3 17.6 11.5 0.4 0 0.4 0.4 17 5 14 305 29 0 29 0 4.2 0.1 4.7 3.9 09/21/2004 07:10:00 15.6 0.9 17.9 12.6 15.7 1 17.9 13 0.4 0 0.4 0.4 17 3 16 305 29 0 29 0 3.9 0.1 4.4 3.7 09/21/2004 07:20:00 15 1 17.2 12.2 15 1.1 17.2 12.2 0.4 0 0.4 0.4 20 6 19 305 29 0 29 0 4 0 4.4 3.7 09/21/2004 07:30:00 15.7 1 17.9 12.6 15.6 1 17.9 12.6 0.4 0 0.4 0.4 21 5 19 305 29 0 29 0 4 0.1 4.4 3.7 09/21/2004 07:40:00 14.7 1.1 16.8 11.1 14.6 1.3 17.2 10.7 0.4 0 0.4 0.4 19 5 21 305 29 0 29 0 4 0.1 4.4 3.9 09/21/2004 07:50:00 15.2 1.1 17.9 11.8 15.2 1.1 17.6 12.6 0.4 0 0.4 0.4 16 4 14 305 29 0 29 0 4 0.1 4.4 3.7 09/21/2004 08:00:00 14.3 1.1 16.4 11.5 14.3 1.2 16.8 10.7 0.4 0 0.4 0.4 17 4 19 305 28 0 28 0 4 0.1 4.4 3.7 09/21/2004 08:10:00 14.7 1 16.8 11.5 14.6 1.2 17.2 11.1 0.4 0 0.4 0.4 20 4 14 305 28 0 28 0 4 0.1 4.4 3.7 09/21/2004 08:20:00 14.6 1 17.2 12.2 14.5 1.2 16.8 10.7 0.4 0 0.4 0.4 20 5 21 305 27 0 27 0 4 0.1 4.4 3.7 09/21/2004 08:30:00 15.1 0.9 16.4 11.8 15.1 1 16.8 12.2 0.4 0 0.4 0.4 21 4 18 305 26 0 26 0 3.9 0.1 4.4 3.7 09/21/2004 08:40:00 14.7 1 16.4 9.9 14.7 1 16.8 11.1 0.4 0 0.4 0.4 21 4 24 305 26 0 26 0 4 0.1 4.4 3.7 09/21/2004 08:50:00 14.3 1 16.4 11.5 14.2 1.2 17.2 11.1 0.4 0 0.4 0.4 20 4 20 305 25 0 25 0 4 0.1 4.4 3.7 09/21/2004 09:00:00 14.5 1 16.4 11.8 14.4 1.1 16.4 11.1 0.4 0 0.4 0.4 23 4 29 305 25 0 25 0 4.1 0.1 4.4 3.9 09/21/2004 09:10:00 14.1 1 16.4 11.1 14 1.1 16.4 11.5 0.4 0 0.4 0.4 22 4 20 305 25 0 25 0 4.2 0.1 4.7 3.9 09/21/2004 09:20:00 14 1.2 17.2 11.1 14 1.3 17.2 11.1 0.4 0 0.4 0.4 21 5 21 305 25 0 25 0 4.2 0 4.7 4.2 09/21/2004 09:30:00 14.4 0.8 16.8 11.8 14.3 1 17.2 11.1 0.4 0 0.4 0.4 19 6 10 305 25 0 25 0 4.2 0 4.7 4.2 09/21/2004 09:40:00 14.1 1.1 16.4 11.1 14 1.2 16.8 11.5 0.4 0 0.4 0.4 24 5 23 305 25 0 25 0 4.4 0.1 4.9 4.2 09/21/2004 09:50:00 14.6 1.4 18.7 10.7 14.6 1.4 18.7 11.1 0.4 0 0.4 0.4 20 5 14 305 26 0 26 0 4.4 0 4.7 4.2 09/21/2004 10:00:00 14.6 1.2 17.6 10.7 14.4 1.3 17.6 11.1 0.4 0 0.4 0.4 19 5 17 305 26 0 26 0 4.4 0.1 4.9 4.2 09/21/2004 10:10:00 15 1 17.2 11.8 14.8 1.1 17.6 11.5 0.4 0 0.4 0.4 17 5 14 305 26 0 26 0 4.4 0.2 4.9 4.4 09/21/2004 10:20:00 14.9 1.2 17.2 10.7 14.9 1.3 17.6 10.3 0.4 0 0.4 0.4 17 5 13 305 27 0 27 0 4.4 0.1 4.9 4.4 09/21/2004 10:30:00 14.3 0.9 16.1 12.2 14.3 1 16.4 11.1 0.4 0 0.4 0.4 18 5 19 305 27 0 27 0 4.4 0.1 4.9 4.4 09/21/2004 10:40:00 15.2 1.5 18.3 11.5 15.1 1.6 18.7 11.5 0.4 0 0.4 0.4 20 7 19 305 27 0 27 0 4.6 0.1 4.9 4.4 09/21/2004 10:50:00 16 1.3 18.3 12.2 15.9 1.4 19.1 12.2 0.4 0 0.4 0.4 17 5 19 305 28 0 28 0 4.4 0.1 4.9 4.4 09/21/2004 11:00:00 16 1.3 18.7 11.8 15.8 1.4 18.7 12.2 0.4 0 0.4 0.4 19 4 18 305 28 0 28 0 4.4 0.1 4.9 4.4 09/21/2004 11:10:00 15.5 1.3 17.9 11.8 15.4 1.3 17.9 11.5 0.4 0 0.7 0.4 20 5 17 305 28 0 28 0 4.4 0.1 4.9 4.4 09/21/2004 11:20:00 15.2 1.3 17.9 10.7 15.1 1.5 18.7 10.3 0.4 0 0.4 0.4 22 5 21 305 29 0 28 0 4.5 0.1 5.2 4.4 09/21/2004 11:30:00 15.4 1.1 17.9 11.8 15.3 1.2 18.3 11.5 0.4 0 0.4 0.4 20 6 15 305 29 0 29 0 4.5 0.1 4.9 4.4 09/21/2004 11:40:00 15.1 1 17.2 11.8 15.1 1.1 17.2 11.8 0.4 0 0.4 0.4 17 5 16 305 29 0 29 0 4.6 0.1 4.9 4.4 09/21/2004 11:50:00 15.4 1.2 18.7 11.5 15.4 1.3 19.5 11.8 0.4 0 0.4 0.4 21 5 16 305 30 0 30 0 4.6 0.1 4.9 4.4 09/21/2004 12:00:00 15.2 1.4 18.7 11.8 15.1 1.4 18.7 11.1 0.4 0 0.4 0.4 19 6 21 305 30 0 30 0 4.6 0.1 4.9 4.4 09/21/2004 12:10:00 15 1.5 17.9 10.3 14.9 1.5 18.3 10.7 0.4 0 0.4 0.4 16 5 16 305 30 0 30 0 4.6 0.1 4.9 4.4 09/21/2004 12:20:00 15.9 1.2 20.2 12.6 15.7 1.2 19.1 12.2 0.4 0 0.4 0.4 15 4 17 305 30 0 30 0 4.5 0.2 4.9 4.2 09/21/2004 12:30:00 15.8 1.7 19.5 11.1 15.9 1.7 19.9 11.8 0.4 0 0.4 0.4 14 5 15 305 30 0 30 0 4.5 0.2 5.2 4.2 09/21/2004 12:40:00 15.6 1.3 18.7 11.8 15.6 1.4 18.7 11.1 0.4 0 0.4 0.4 20 5 19 305 28 1 29 0 4.8 0.1 5.4 4.7 09/21/2004 12:50:00 15.2 1 17.9 12.2 15.2 1.1 17.9 12.2 0.4 0 0.4 0.4 16 4 15 305 25 0 25 0 4.7 0.2 5.4 4.4 09/21/2004 13:00:00 14.4 1 16.8 10.7 14.6 1.1 16.8 11.8 0.4 0 0.4 0.4 18 5 14 305 24 0 24 0 4.7 0.1 5.2 4.4 09/21/2004 13:10:00 14.7 1.2 18.7 11.1 14.7 1.3 19.5 11.5 0.4 0 0.4 0.4 18 5 21 305 24 0 24 0 4.6 0.1 5.2 4.4 09/21/2004 13:20:00 14.4 1.2 17.9 11.1 14.4 1.3 17.9 11.1 0.4 0 0.4 0.4 16 5 20 305 25 0 25 0 4.7 0.1 5.2 4.4 09/21/2004 13:30:00 14.8 0.8 17.6 12.2 14.8 0.9 17.6 12.2 0.4 0 0.4 0.4 12 4 14 305 25 0 25 0 4.6 0.1 5.2 4.4 09/21/2004 13:40:00 14.9 1.5 17.9 11.1 14.9 1.5 18.3 11.5 0.4 0 0.4 0.4 17 4 14 305 25 0 25 0 4.7 0.1 5.2 4.4 09/21/2004 13:50:00 15.1 1.2 17.9 11.8 15 1.2 17.2 11.8 0.4 0 0.4 0.4 16 4 22 305 25 0 25 0 4.6 0.1 4.9 4.4 09/21/2004 14:00:00 14.2 1.2 16.4 11.1 14.2 1.3 16.8 10.7 0.4 0 0.4 0.4 15 5 13 305 24 0 25 0 4.6 0.1 4.9 4.4 09/21/2004 14:10:00 13.4 0.8 15.3 11.1 13.4 0.8 15.6 11.1 0.4 0 0.4 0.4 16 5 19 305 23 1 24 0 4.4 0.2 4.9 3.9 09/21/2004 14:20:00 14.8 1.7 18.7 11.5 14.7 1.7 18.7 11.1 0.4 0 0.4 0.4 21 5 16 305 22 0 22 0 3.8 0.3 4.7 3.2 09/21/2004 14:30:00 14.1 1.2 17.2 11.1 14 1.3 17.2 9.9 0.4 0 0.4 0.4 19 6 14 305 22 0 22 0 4.4 0 4.9 4.2 09/21/2004 14:40:00 14.2 1.1 16.4 10.3 14.2 1.1 16.4 11.1 0.4 0 0.4 0.4 14 4 11 305 21 0 21 0 4.3 0 4.7 4.2 09/21/2004 14:50:00 14.7 1.2 17.6 11.8 14.8 1.2 17.6 11.8 0.4 0 0.4 0.4 18 6 21 305 20 0 20 0 4.4 0.1 4.9 4.2 09/21/2004 15:00:00 14.8 0.8 16.8 12.2 14.9 0.9 16.8 11.5 0.4 0 0.4 0.4 15 5 21 305 20 1 20 0 4.4 0.1 4.9 4.2 09/21/2004 15:10:00 15.4 1 18.3 12.6 15.4 1.1 18.7 11.5 0.4 0 0.4 0.4 16 4 20 305 20 0 20 0 4.4 0.1 4.9 4.2 09/21/2004 15:20:00 14.9 1.5 17.6 10.3 15 1.4 18.3 11.8 0.4 0 0.4 0.4 18 4 17 305 20 0 20 0 4.6 0.1 5.4 4.4 09/21/2004 15:30:00 15 0.9 17.2 11.5 15.1 1 17.2 11.8 0.4 0 0.4 0.4 14 4 9 305 18 1 18 0 4.5 0.1 5.2 4.4 09/21/2004 15:40:00 15 1 17.6 12.2 15.1 1.1 17.9 11.8 0.4 0 0.4 0.4 17 5 16 305 14 1 15 0 4.5 0.1 4.9 4.4 09/21/2004 15:50:00 15.1 1 17.9 12.6 15.1 1.1 17.6 11.5 0.4 0 0.4 0.4 18 6 31 305 6 3 4 0 4.6 0.1 4.9 4.4 09/21/2004 16:00:00 15.5 1.3 19.5 11.5 15.5 1.4 19.1 11.8 0.4 0 0.4 0.4 19 5 21 305 2 1 0 0 4.7 0 5.2 4.4 09/21/2004 16:10:00 16.2 1.1 18.7 13 16 1.2 18.7 12.6 0.4 0 0.4 0.4 24 4 25 305 0 0 0 0 4.8 0 5.2 4.7 09/21/2004 16:20:00 15.4 1.1 17.9 12.2 15.4 1.2 17.9 11.5 0.4 0 0.4 0.4 20 5 19 305 0 0 0 0 4.8 0 5.4 4.7 09/21/2004 16:30:00 14.9 1.2 17.6 11.1 14.8 1.3 17.6 10.7 0.4 0 0.4 0.4 20 5 19 305 0 0 0 0 4.8 0.1 5.4 4.7 09/21/2004 16:40:00 15.6 1.4 18.3 11.8 15.6 1.4 18.3 11.5 0.4 0 0.4 0.4 16 4 11 305 0 0 0 0 4.9 0.1 5.4 4.7 09/21/2004 16:50:00 15.3 1.3 17.9 11.8 15.3 1.4 18.3 11.5 0.4 0 0.4 0.4 20 4 19 305 0 0 0 0 4.8 0 5.2 4.7 09/21/2004 17:00:00 15.3 1.2 17.9 11.8 15.1 1.3 17.9 11.5 0.4 0 0.4 0.4 17 3 17 305 0 0 0 0 4.8 0 5.4 4.7 09/21/2004 17:10:00 14.5 1.1 16.8 11.8 14.5 1.2 17.2 11.5 0.4 0 0.4 0.4 17 5 14 305 0 0 0 0 5 0.2 5.4 4.9 09/21/2004 17:20:00 14.8 1.1 17.2 11.8 14.8 1.2 17.9 11.5 0.4 0 0.4 0.4 25 3 18 305 0 0 0 0 4.7 0.1 5.4 4.4 09/21/2004 17:30:00 15.2 1 17.2 12.2 15.2 1.1 17.2 11.1 0.4 0 0.4 0.4 23 4 21 305 0 0 0 0 4.8 0 5.4 4.7 09/21/2004 17:40:00 14.8 0.9 17.2 11.8 14.7 1 17.6 11.8 0.4 0 0.4 0.4 19 5 22 305 0 0 0 0 5 0.1 5.4 4.7 09/21/2004 17:50:00 14.5 1.2 17.2 11.5 14.5 1.2 17.6 11.1 0.4 0 0.4 0.4 20 5 20 305 0 0 0 0 4.9 0.1 5.4 4.7 09/21/2004 18:00:00 14.7 1.1 17.9 11.8 14.6 1.2 17.6 10.7 0.4 0 0.4 0.4 22 4 18 305 0 0 0 0 4.9 0.1 5.4 4.7 09/21/2004 18:10:00 14.7 0.8 16.8 12.6 14.6 0.9 17.2 11.1 0.4 0 0.4 0.4 17 4 18 305 0 0 0 0 4.9 0 5.4 4.9 09/21/2004 18:20:00 14 1.1 16.8 11.1 14 1.2 17.2 11.1 0.4 0 0.4 0.4 19 4 20 305 0 0 0 0 4.9 0 5.4 4.7 09/21/2004 18:30:00 15 1.3 18.3 11.5 15 1.4 18.3 11.5 0.4 0 0.4 0.4 21 3 18 305 0 0 0 0 5 0.1 5.4 4.7 09/21/2004 18:40:00 15.5 1 19.1 13 15.5 1.1 18.3 12.6 0.4 0 0.4 0.4 20 4 15 305 0 0 0 0 4.9 0 5.4 4.7 09/21/2004 18:50:00 15 1.5 17.9 10.3 14.9 1.6 17.9 10.3 0.4 0 0.4 0.4 20 4 21 305 0 0 0 0 4.8 0 5.4 4.7 09/21/2004 19:00:00 14.6 1 16.8 11.5 14.6 1.1 16.8 11.1 0.4 0 0.4 0.4 19 5 10 305 0 0 0 0 5 0.1 5.4 4.9 09/21/2004 19:10:00 14 1.2 16.4 11.1 13.9 1.3 16.4 10.7 0.4 0 0.4 0.4 19 5 25 305 0 0 0 0 5 0.1 5.6 4.9 09/21/2004 19:20:00 14.8 1.1 17.2 11.5 14.8 1.2 17.2 11.5 0.4 0 0.4 0.4 23 3 24 305 0 0 0 0 4.9 0.1 5.4 4.7 09/21/2004 19:30:00 14.1 1 16.1 11.5 14.1 1.1 16.4 11.1 0.4 0 0.4 0.4 23 4 23 305 0 0 0 0 4.9 0 5.4 4.7 09/21/2004 19:40:00 14.6 1.1 16.8 11.5 14.6 1.2 16.8 11.1 0.4 0 0.4 0.4 23 5 18 305 0 0 0 0 4.9 0 5.4 4.7 09/21/2004 19:50:00 13.8 0.9 15.6 11.8 13.8 1 16.1 10.7 0.4 0 0.4 0.4 22 4 21 305 0 0 0 0 4.8 0 5.4 4.7 09/21/2004 20:00:00 14 0.9 16.1 11.5 14 1 16.1 11.5 0.4 0 0.4 0.4 20 4 16 305 0 0 0 0 4.9 0 5.4 4.7 09/21/2004 20:10:00 13.2 1.2 15.6 9.9 13.1 1.2 16.1 10.3 0.4 0 0.4 0.4 22 5 23 305 0 0 0 0 4.8 0 5.4 4.7 09/21/2004 20:20:00 14.2 0.9 16.1 10.7 14.1 1 16.1 11.1 0.4 0 0.4 0.4 25 4 25 305 0 0 0 0 4.8 0.1 5.4 4.7 09/21/2004 20:30:00 13.6 0.8 15.6 11.1 13.6 1 16.1 11.1 0.4 0 0.4 0.4 22 5 23 305 0 0 0 0 4.8 0 5.4 4.7 09/21/2004 20:40:00 13.7 0.8 15.3 11.1 13.7 1 16.1 11.1 0.4 0 0.4 0.4 21 5 24 305 0 0 0 0 4.9 0 5.4 4.7 09/21/2004 20:50:00 14 0.9 15.6 10.7 14 0.9 16.1 11.1 0.4 0 0.4 0.4 21 3 23 305 0 0 0 0 4.8 0 5.4 4.7 09/21/2004 21:00:00 13.3 0.8 15.3 10.3 13.3 1 15.3 10.7 0.4 0 0.4 0.4 25 4 23 305 0 0 0 0 4.9 0 5.4 4.9 09/21/2004 21:10:00 13.6 0.7 15.3 11.5 13.5 0.8 15.3 10.7 0.4 0 0.4 0.4 25 3 23 305 0 0 0 0 4.8 0 5.4 4.7 09/21/2004 21:20:00 13.4 1.1 16.1 10.7 13.4 1 16.1 10.7 0.4 0 0.4 0.4 27 4 27 305 0 0 0 0 4.8 0 5.4 4.7 09/21/2004 21:30:00 13 1 15.3 10.3 13.1 1 15.3 10.7 0.4 0 0.4 0.4 26 4 23 305 0 0 0 0 4.9 0 5.4 4.9 09/21/2004 21:40:00 12.7 1 14.5 9.9 12.7 1.1 14.5 9.9 0.4 0 0.4 0.4 22 4 28 305 0 0 0 0 5 0.1 5.4 4.9 09/21/2004 21:50:00 12.4 1 14.5 9.5 12.4 1 14.5 9.5 0.4 0 0.4 0.4 21 5 18 305 0 0 0 0 5.1 0.1 5.6 4.9 09/21/2004 22:00:00 12.6 0.7 14.1 10.3 12.6 0.8 14.9 9.9 0.4 0 0.4 0.4 22 4 22 305 0 0 0 0 5 0.1 5.4 4.9 09/21/2004 22:10:00 12.3 1 14.5 9.9 12.4 1 14.5 8.8 0.4 0 0.4 0.4 21 4 22 305 0 0 0 0 5 0.1 5.4 4.9 09/21/2004 22:20:00 12 0.7 13.7 9.9 12 0.8 13.7 9.5 0.4 0 0.4 0.4 22 4 21 305 0 0 0 0 5 0.1 5.4 4.9 09/21/2004 22:30:00 11.6 0.8 13.3 9.5 11.7 0.9 13.3 9.5 0.4 0 0.4 0.4 20 4 12 305 0 0 0 0 5 0.1 5.4 4.9 09/21/2004 22:40:00 11.2 0.8 13 8.8 11.2 0.9 13 8.8 0.4 0 0.4 0.4 17 4 19 305 0 0 0 0 5.2 0.1 5.6 4.9 09/21/2004 22:50:00 11.8 0.7 14.1 9.9 11.9 0.8 13.7 9.5 0.4 0 0.4 0.4 19 5 15 305 0 0 0 0 5.2 0 5.6 4.9 09/21/2004 23:00:00 11.3 0.8 13 8.8 11.3 0.8 13.3 8.4 0.4 0 0.4 0.4 15 4 17 305 0 0 0 0 5.2 0 5.6 5.2 09/21/2004 23:10:00 11.3 0.9 13 8.4 11.4 0.8 13.3 8.4 0.4 0 0.4 0.4 16 3 22 305 0 0 0 0 5.2 0 5.6 4.9 09/21/2004 23:20:00 10.7 1 12.6 8 10.8 1.1 13 8.4 0.4 0 0.4 0.4 17 4 14 305 0 0 0 0 5.3 0.1 5.6 5.2 09/21/2004 23:30:00 10.9 0.7 12.6 8.8 11.1 0.7 13 8.8 0.4 0 0.4 0.4 15 3 9 305 0 0 0 0 5.2 0.1 5.6 5.2 09/21/2004 23:40:00 10.4 0.7 11.8 8 10.4 0.8 12.2 8 0.4 0 0.4 0.4 15 5 9 305 0 0 0 0 5.2 0 5.6 4.9 09/21/2004 23:50:00 9.9 0.9 12.2 7.6 10.1 1 13 7.6 0.4 0 0.4 0.4 8 4 8 305 0 0 0 0 5.2 0.1 5.6 4.9 09/22/2004 00:00:00 10.1 0.7 11.8 8.4 10.3 0.7 12.2 8 0.4 0 0.4 0.4 7 4 0 305 0 0 0 0 5.2 0.1 5.6 4.9 09/22/2004 00:10:00 10.1 0.7 11.5 8 10.2 0.8 12.2 7.6 0.4 0 0.4 0.4 5 4 7 305 0 0 0 0 5.2 0.2 5.6 4.9 09/22/2004 00:20:00 10 0.7 11.8 8.4 10.2 0.7 11.8 8 0.4 0 0.4 0.4 0 4 1 305 0 0 0 0 5.1 0.2 5.6 4.9 09/22/2004 00:30:00 9.4 0.8 11.5 6.8 9.6 0.8 11.5 6.8 0.4 0 0.4 0.4 3 4 358 305 0 0 0 0 4.9 0.1 5.4 4.7 09/22/2004 00:40:00 8.1 0.8 9.9 6.1 8.4 0.8 10.3 6.1 0.4 0 0.4 0.4 358 5 358 305 0 0 0 0 4.9 0 5.4 4.7 09/22/2004 00:50:00 8.7 0.7 9.9 6.8 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 354 4 352 305 0 0 0 0 4.8 0 5.4 4.7 09/22/2004 01:00:00 9.6 0.6 11.1 7.6 9.8 0.7 11.1 7.6 0.4 0 0.4 0.4 356 4 358 305 0 0 0 0 4.7 0 5.2 4.7 09/22/2004 01:10:00 10.3 0.7 11.8 8.8 10.6 0.7 12.6 8.8 0.4 0 0.4 0.4 357 3 358 305 0 0 0 0 4.7 0 4.9 4.7 09/22/2004 01:20:00 11.4 0.6 12.6 9.5 11.6 0.7 13 8.8 0.4 0 0.4 0.4 2 5 5 305 0 0 0 0 4.7 0 5.2 4.7 09/22/2004 01:30:00 10 0.8 11.8 8 10.3 0.8 12.2 8 0.4 0 0.4 0.4 356 5 350 305 0 0 0 0 4.7 0 5.2 4.4 09/22/2004 01:40:00 9.5 0.7 11.1 7.6 9.8 0.8 11.8 7.6 0.4 0 0.4 0.4 356 4 354 305 0 0 0 0 4.5 0.1 4.9 4.4 09/22/2004 01:50:00 9.5 0.7 11.1 7.6 9.8 0.7 11.8 8 0.4 0 0.4 0.4 356 5 351 305 0 0 0 0 4.5 0.1 4.9 4.4 09/22/2004 02:00:00 9 0.6 10.7 6.8 9.3 0.7 11.1 6.8 0.4 0 0.4 0.4 353 5 345 305 0 0 0 0 4.5 0.1 4.9 4.4 09/22/2004 02:10:00 9.5 0.8 11.5 7.2 9.7 0.8 11.5 7.2 0.4 0 0.4 0.4 350 5 353 305 0 0 0 0 4.5 0.1 4.9 4.4 09/22/2004 02:20:00 10.1 0.7 11.5 8 10.4 0.8 11.8 8 0.4 0 0.4 0.4 351 4 358 305 0 0 0 0 4.4 0 4.9 4.2 09/22/2004 02:30:00 10.8 0.9 13.3 8 11.1 1 13.3 8 0.4 0 0.4 0.4 351 3 353 305 0 0 0 0 4.4 0 4.7 4.2 09/22/2004 02:40:00 11 0.7 13 8.4 11.3 0.8 13 9.1 0.4 0 0.4 0.4 351 5 344 305 0 0 0 0 4.4 0 4.7 4.2 09/22/2004 02:50:00 10.8 0.9 12.2 8.4 11.1 1 13 8 0.4 0 0.4 0.4 346 3 352 305 0 0 0 0 4.4 0 4.7 4.2 09/22/2004 03:00:00 10.1 0.6 11.8 8.4 10.4 0.7 12.6 8.8 0.4 0 0.4 0.4 351 6 348 305 0 0 0 0 4.4 0 4.4 4.2 09/22/2004 03:10:00 11.1 0.9 13.3 8.8 11.3 1 13.3 9.1 0.4 0 0.4 0.4 353 4 347 305 0 0 0 0 4.4 0.1 4.9 4.4 09/22/2004 03:20:00 11.3 0.8 13 9.1 11.6 0.8 13.3 9.5 0.4 0 0.4 0.4 352 5 348 305 0 0 0 0 4.5 0.2 4.9 4.4 09/22/2004 03:30:00 10.4 1 12.6 8 10.8 1 13 7.6 0.4 0 0.4 0.4 352 4 351 305 0 0 0 0 4.4 0 4.9 4.2 09/22/2004 03:40:00 10 0.6 11.5 7.6 10.2 0.7 11.8 8 0.4 0 0.4 0.4 352 3 349 305 0 0 0 0 4.2 0.1 4.7 3.9 09/22/2004 03:50:00 9.3 0.8 11.1 6.8 9.5 0.9 11.5 6.5 0.4 0 0.4 0.4 356 5 352 305 0 0 0 0 4.1 0.1 4.4 3.9 09/22/2004 04:00:00 9.8 0.8 11.8 6.8 10 0.8 11.8 7.6 0.4 0 0.4 0.4 0 4 356 305 0 0 0 0 4.2 0.1 4.7 4.2 09/22/2004 04:10:00 9.6 0.6 10.7 7.2 9.7 0.6 11.1 7.6 0.4 0 0.4 0.4 2 5 6 305 0 0 0 0 4.2 0.2 4.7 3.9 09/22/2004 04:20:00 10.2 0.8 11.5 7.6 10.4 0.8 11.8 7.6 0.4 0 0.4 0.4 356 4 353 305 0 0 0 0 4.3 0.1 4.7 4.2 09/22/2004 04:30:00 10.3 0.7 11.8 8 10.6 0.8 12.6 8 0.4 0 0.4 0.4 357 3 355 305 0 0 0 0 4.3 0.1 4.7 4.2 09/22/2004 04:40:00 9.9 0.8 11.5 7.6 10.1 0.9 11.8 7.6 0.4 0 0.4 0.4 353 4 351 305 0 0 0 0 4.2 0.1 4.7 3.9 09/22/2004 04:50:00 9.4 0.7 11.1 7.6 9.6 0.8 11.5 7.2 0.4 0 0.4 0.4 359 3 358 305 0 0 0 0 4.2 0.1 4.7 3.9 09/22/2004 05:00:00 8.8 0.6 10.3 7.2 9 0.6 10.3 7.2 0.4 0 0.4 0.4 357 4 354 305 0 0 0 0 4.2 0.1 4.7 3.9 09/22/2004 05:10:00 8.5 0.6 10.3 6.8 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 356 5 358 305 0 0 0 0 4.2 0.1 4.7 3.9 09/22/2004 05:20:00 8.9 0.6 10.3 6.8 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 356 5 3 305 0 0 0 0 4.1 0.1 4.7 3.9 09/22/2004 05:30:00 9.5 0.8 11.5 7.2 9.7 0.8 11.5 7.2 0.4 0 0.4 0.4 351 4 353 305 0 0 0 0 4 0 4.4 4.2 09/22/2004 05:40:00 10.1 0.7 11.8 8.4 10.4 0.8 12.2 8.4 0.4 0 0.4 0.4 347 4 350 305 0 0 0 0 4.2 0 4.7 4.2 09/22/2004 05:50:00 10.8 0.6 12.2 9.1 11.1 0.6 12.2 9.1 0.4 0 0.4 0.4 349 3 346 305 0 0 0 0 4.2 0 4.7 4.2 09/22/2004 06:00:00 10.7 0.8 13 8.4 10.9 0.9 13.3 8.8 0.4 0 0.4 0.4 345 5 346 305 0 0 0 0 4.3 0 4.7 4.2 09/22/2004 06:10:00 9.3 0.6 10.7 7.6 9.6 0.7 11.1 8 0.4 0 0.4 0.4 345 6 347 305 0 0 0 0 4.3 0 4.7 4.2 09/22/2004 06:20:00 9.5 0.9 11.1 6.8 9.7 1 11.8 6.8 0.4 0 0.4 0.4 353 4 355 305 0 0 0 0 4.3 0 4.4 4.2 09/22/2004 06:30:00 9.7 0.8 11.5 7.6 10 0.8 11.8 8 0.4 0 0.4 0.4 353 4 351 305 0 0 0 0 4.2 0 4.4 4.2 09/22/2004 06:40:00 9.7 0.8 11.8 7.2 10 1 12.2 6.5 0.4 0 0.4 0.4 352 4 355 305 0 0 0 0 4.2 0 4.4 4.2 09/22/2004 06:50:00 9.3 0.8 11.5 6.5 9.5 0.9 11.1 7.2 0.4 0 0.4 0.4 351 6 358 305 0 0 0 0 4.2 0 4.4 4.2 09/22/2004 07:00:00 10.4 0.8 13.7 8.8 10.6 0.8 13.3 8.8 0.4 0 0.4 0.4 355 5 359 305 0 0 0 0 4 0 4.4 3.9 09/22/2004 07:10:00 10.3 0.7 13.3 8.8 10.5 0.8 13.3 8.4 0.4 0 0.4 0.4 353 5 353 305 0 0 0 0 3.9 0 4.4 3.7 09/22/2004 07:20:00 10.5 0.8 13.3 8.8 10.7 0.8 13.3 8.4 0.4 0 0.4 0.4 349 4 352 305 0 0 0 0 3.8 0 4.2 3.7 09/22/2004 07:30:00 11.3 1.1 13.7 8.8 11.5 1.1 14.1 8.8 0.4 0 0.4 0.4 346 4 346 305 0 0 0 0 3.7 0 4.4 3.7 09/22/2004 07:40:00 12.3 0.9 14.5 10.3 12.4 1 14.9 10.3 0.4 0 0.4 0.4 349 4 351 305 0 0 0 0 3.7 0 4.2 3.7 09/22/2004 07:50:00 11.8 0.9 13.7 9.5 12.1 1 14.1 8.8 0.4 0 0.4 0.4 353 4 348 305 0 0 0 0 3.7 0 4.2 3.7 09/22/2004 08:00:00 11 1 13 8.4 11.3 1 13.3 8.4 0.4 0 0.4 0.4 354 4 352 305 0 0 0 0 3.7 0.1 4.2 3.4 09/22/2004 08:10:00 11 0.8 13 8.8 11.2 0.9 13.3 9.1 0.4 0 0.4 0.4 355 5 353 305 0 0 0 0 3.7 0.1 4.2 3.4 09/22/2004 08:20:00 10.3 0.7 12.2 8 10.6 0.8 12.2 8 0.4 0 0.4 0.4 359 5 357 305 0 0 0 0 3.7 0.2 4.2 3.4 09/22/2004 08:30:00 9.4 0.8 11.1 6.8 9.7 0.8 11.8 7.6 0.4 0 0.4 0.4 357 5 356 305 0 0 0 0 3.7 0.2 4.2 3.4 09/22/2004 08:40:00 9.9 0.7 11.5 7.6 10.1 0.7 12.2 8 0.4 0 0.4 0.4 355 5 355 305 0 0 0 0 3.6 0.2 4.2 3.4 09/22/2004 08:50:00 9.6 0.8 11.1 7.6 9.9 0.8 11.8 8 0.4 0 0.4 0.4 354 5 351 305 0 0 0 0 3.5 0.2 3.9 3.4 09/22/2004 09:00:00 9.2 0.5 10.7 7.6 9.5 0.5 10.7 7.6 0.4 0 0.4 0.4 352 5 1 305 0 0 0 0 3.5 0.2 3.9 3.2 09/22/2004 09:10:00 8.7 1.1 11.1 6.1 9 1.2 11.5 6.5 0.4 0 0.4 0.4 354 5 0 305 0 0 0 0 3.6 0.1 4.2 3.4 09/22/2004 09:20:00 9.7 0.7 11.8 8 10 0.8 12.2 8 0.4 0 0.4 0.4 352 5 350 305 0 0 0 0 3.8 0.2 4.4 3.4 09/22/2004 09:30:00 9.2 0.7 11.1 7.2 9.5 0.7 11.1 8 0.4 0 0.4 0.4 355 5 8 305 0 0 0 0 3.9 0.1 4.4 3.7 09/22/2004 09:40:00 8.9 0.6 10.7 7.2 9.2 0.6 11.1 7.2 0.4 0 0.4 0.4 353 4 352 305 0 0 0 0 4 0.2 4.4 3.7 09/22/2004 09:50:00 8.7 0.6 10.3 7.2 8.9 0.6 10.7 7.2 0.4 0 0.4 0.4 351 5 353 305 0 0 0 0 3.9 0.1 4.4 3.7 09/22/2004 10:00:00 9.1 0.7 10.7 7.2 9.4 0.8 11.5 6.8 0.4 0 0.4 0.4 355 6 356 305 0 0 0 0 3.9 0.1 4.4 3.7 09/22/2004 10:10:00 8.5 0.8 10.7 6.8 8.8 0.8 11.1 7.2 0.4 0 0.4 0.4 354 4 351 305 0 0 0 0 3.9 0.1 4.4 3.7 09/22/2004 10:20:00 8 0.6 9.5 6.1 8.3 0.6 9.9 6.5 0.4 0 0.4 0.4 352 6 345 305 0 0 0 0 4 0.1 4.4 3.7 09/22/2004 10:30:00 7.5 0.6 8.8 5.7 7.7 0.6 9.5 5.7 0.4 0 0.4 0.4 355 6 351 305 0 0 0 0 4 0.1 4.4 3.7 09/22/2004 10:40:00 7.2 0.6 8.4 5.7 7.5 0.6 8.8 6.1 0.4 0 0.4 0.4 356 7 353 305 0 0 0 0 3.9 0.1 4.7 3.7 09/22/2004 10:50:00 7 0.5 8 5.3 7.3 0.5 8.8 4.9 0.4 0 0.4 0.4 350 5 347 305 0 0 0 0 3.8 0 4.4 3.7 09/22/2004 11:00:00 6.8 0.6 8.8 4.6 7.1 0.6 8.8 5.3 0.4 0 0.4 0.4 352 7 8 305 0 0 0 0 3.8 0.1 4.4 3.7 09/22/2004 11:10:00 6.9 0.7 8.4 5.3 7.2 0.8 8.8 5.3 0.4 0 0.4 0.4 353 6 353 305 0 0 0 0 3.9 0.1 4.4 3.7 09/22/2004 11:20:00 6.7 0.5 8 4.9 7 0.6 8.4 5.3 0.4 0 0.4 0.4 351 5 356 305 0 0 0 0 3.9 0.2 4.7 3.4 09/22/2004 11:30:00 6.5 0.6 8 5.3 6.8 0.6 8.4 5.3 0.4 0 0.4 0.4 352 5 350 305 0 0 0 0 4 0.2 4.4 3.7 09/22/2004 11:40:00 6.2 0.8 8.4 4.6 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 350 5 344 305 0 0 0 0 3.9 0.1 4.4 3.7 09/22/2004 11:50:00 6.4 0.6 7.6 4.9 6.7 0.6 8 4.9 0.4 0 0.4 0.4 348 5 344 305 0 0 0 0 4 0.1 4.4 3.7 09/22/2004 12:00:00 5.7 0.7 7.2 3.8 6 0.7 7.6 4.6 0.4 0 0.4 0.4 347 5 344 305 0 0 0 0 4.1 0.1 4.7 3.7 09/22/2004 12:10:00 5.9 0.5 7.2 4.6 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 352 7 350 305 0 0 0 0 4.3 0.1 4.9 3.9 09/22/2004 12:20:00 6 0.7 7.6 4.2 6.1 0.7 8 4.2 0.4 0 0.4 0.4 4 6 5 305 0 0 0 0 4 0.3 4.7 3.4 09/22/2004 12:30:00 6.1 0.6 8 4.6 6.3 0.6 8.4 4.6 0.4 0 0.4 0.4 4 6 3 305 0 0 0 0 3.6 0.1 4.2 3.4 09/22/2004 12:40:00 5.8 0.5 7.2 4.6 6 0.6 7.6 4.6 0.4 0 0.4 0.4 1 7 1 305 0 0 0 0 3.5 0.1 3.9 3.4 09/22/2004 12:50:00 5.4 0.6 7.2 3.8 5.6 0.7 7.6 3.8 0.4 0 0.4 0.4 5 7 19 305 0 0 0 0 3.4 0.1 3.7 3.2 09/22/2004 13:00:00 5.6 0.5 6.8 4.2 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 7 4 12 305 0 0 0 0 3.4 0.2 3.7 3.2 09/22/2004 13:10:00 5.8 0.6 6.8 3.8 6 0.6 7.2 4.2 0.4 0 0.4 0.4 8 5 359 305 0 0 0 0 3.4 0.2 3.7 3.2 09/22/2004 13:20:00 5.5 0.5 6.8 4.2 5.7 0.6 6.8 3.8 0.4 0 0.4 0.4 1 5 356 305 0 0 0 0 3.6 0.1 4.2 3.4 09/22/2004 13:30:00 5.3 0.5 6.8 4.2 5.5 0.5 7.2 4.6 0.4 0 0.4 0.4 0 5 3 305 0 0 0 0 3.6 0.1 3.9 3.4 09/22/2004 13:40:00 5.7 0.5 7.6 3.8 6 0.5 7.6 4.6 0.4 0 0.4 0.4 358 5 357 305 0 0 0 0 3.6 0.1 4.2 3.4 09/22/2004 13:50:00 5.7 0.5 6.8 4.6 5.9 0.5 7.2 4.2 0.4 0 0.4 0.4 359 5 355 305 0 0 0 0 3.7 0.1 4.2 3.4 09/22/2004 14:00:00 5.4 0.5 6.5 4.2 5.7 0.5 6.5 4.2 0.4 0 0.4 0.4 359 5 2 305 0 0 0 0 3.9 0.2 4.4 3.7 09/22/2004 14:10:00 5.6 0.5 6.8 4.2 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 2 5 8 305 0 0 0 0 3.9 0.2 4.4 3.7 09/22/2004 14:20:00 4.8 0.5 5.7 3.4 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 355 5 356 305 0 0 0 0 4 0.2 4.4 3.7 09/22/2004 14:30:00 4.6 0.5 5.7 3.4 4.8 0.6 6.1 3.8 0.4 0 0.4 0.4 0 6 3 305 0 0 0 0 4 0.2 4.7 3.7 09/22/2004 14:40:00 4.6 0.5 6.5 3 4.9 0.6 6.5 3 0.4 0 0.4 0.4 359 8 0 305 0 0 0 0 4 0.2 4.4 3.7 09/22/2004 14:50:00 4.4 0.5 5.3 2.6 4.6 0.5 5.7 3 0.4 0 0.4 0.4 358 5 16 305 0 0 0 0 3.9 0.1 4.4 3.7 09/22/2004 15:00:00 4 0.6 5.7 2.6 4.2 0.6 5.7 3 0.4 0 0.4 0.4 5 7 354 305 0 0 0 0 3.9 0.1 4.4 3.7 09/22/2004 15:10:00 4.2 0.6 5.3 2.6 4.4 0.6 5.7 3 0.4 0 0.4 0.4 6 8 359 305 0 0 0 0 3.8 0 4.4 3.4 09/22/2004 15:20:00 4 0.8 5.3 2.3 4.2 0.8 5.7 2.6 0.4 0 0.4 0.4 2 6 353 305 0 0 0 0 3.6 0 4.2 3.4 09/22/2004 15:30:00 3.7 0.6 5.3 2.3 3.9 0.6 5.7 2.3 0.4 0 0.4 0.4 358 9 354 305 0 0 0 0 3.7 0 4.2 3.4 09/22/2004 15:40:00 3.3 0.6 4.6 1.9 3.5 0.6 4.6 1.9 0.4 0 0.4 0.4 359 9 4 305 0 0 0 0 3.6 0.1 4.2 3.4 09/22/2004 15:50:00 3.4 0.4 4.6 2.3 3.6 0.4 4.6 2.6 0.4 0 0.4 0.4 349 8 353 305 0 0 0 0 3.6 0.1 4.2 3.4 09/22/2004 16:00:00 3.2 0.5 4.2 1.9 3.6 0.5 4.6 2.3 0.4 0 0.4 0.4 349 11 343 305 0 0 0 0 3.4 0.1 3.9 3.2 09/22/2004 16:10:00 3 0.4 3.8 2.3 3.3 0.4 4.2 2.3 0.4 0 0.4 0.4 356 7 8 305 0 0 0 0 3.3 0 3.7 3.2 09/22/2004 16:20:00 2.6 0.4 3.4 1.5 2.9 0.4 3.8 1.9 0.4 0 0.4 0.4 11 16 347 305 0 0 0 0 3.2 0 3.7 3.2 09/22/2004 16:30:00 2.6 0.5 4.2 1.5 2.9 0.5 4.2 1.5 0.4 0 0.4 0.4 10 7 12 305 0 0 0 0 3.2 0 3.7 2.9 09/22/2004 16:40:00 2.5 0.3 3.4 1.9 2.8 0.3 3.4 2.3 0.4 0 0.4 0.4 28 7 27 305 0 0 0 0 3.3 0 3.7 3.2 09/22/2004 16:50:00 2.8 0.4 3.8 1.5 3 0.3 3.8 2.3 0.4 0 0.4 0.4 32 7 35 305 0 0 0 0 3.3 0.1 3.7 3.2 09/22/2004 17:00:00 3.1 0.3 3.8 2.3 3.2 0.3 3.8 2.3 0.4 0 0.4 0.4 30 6 27 305 0 0 0 0 3.3 0.1 3.7 3.2 09/22/2004 17:10:00 3.4 0.3 4.6 2.6 3.6 0.3 4.6 2.6 0.4 0 0.4 0.4 14 5 13 305 0 0 0 0 3.3 0.1 3.7 3.2 09/22/2004 17:20:00 3.7 0.4 4.6 2.6 3.9 0.4 4.9 3 0.4 0 0.4 0.4 13 5 17 305 0 0 0 0 3.5 0.1 3.9 3.2 09/22/2004 17:30:00 4.3 0.4 5.3 3.4 4.4 0.4 5.7 3.4 0.4 0 0.4 0.4 10 8 12 305 0 0 0 0 3.6 0 4.2 3.4 09/22/2004 17:40:00 3.8 0.4 5.3 2.6 4 0.5 5.3 3 0.4 0 0.4 0.4 4 6 4 305 0 0 0 0 3.7 0 4.2 3.4 09/22/2004 17:50:00 3.8 0.6 5.3 2.3 3.9 0.5 5.7 3 0.4 0 0.4 0.4 6 7 0 305 0 0 0 0 3.4 0.2 4.2 3.2 09/22/2004 18:00:00 3.2 0.4 4.6 2.3 3.4 0.4 4.6 2.3 0.4 0 0.4 0.4 21 8 16 305 0 0 0 0 3.3 0.1 3.7 3.2 09/22/2004 18:10:00 3.5 0.6 5.3 2.3 3.7 0.6 5.7 2.6 0.4 0 0.4 0.4 14 8 24 305 0 0 0 0 3.3 0.1 3.7 3.2 09/22/2004 18:20:00 3.1 0.3 3.8 2.3 3.3 0.3 4.2 2.6 0.4 0 0.4 0.4 11 5 3 305 0 0 0 0 3.1 0.2 3.7 2.9 09/22/2004 18:30:00 2.2 0.6 3.4 0.7 2.5 0.6 3.8 1.5 0.4 0 0.4 0.4 25 11 28 305 0 0 0 0 2.9 0.1 3.4 2.7 09/22/2004 18:40:00 2.1 0.6 4.2 1.1 2.5 0.6 4.6 1.1 0.4 0 0.4 0.4 13 8 24 305 0 0 0 0 3.2 0.1 3.7 2.9 09/22/2004 18:50:00 2.4 1.1 4.9 0.4 2.8 0.9 5.3 0.7 0.4 0 0.4 0.4 15 10 20 305 0 0 0 0 3.3 0.1 3.7 3.2 09/22/2004 19:00:00 4.4 0.5 5.3 3 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 16 7 15 305 0 0 0 0 3.3 0.1 3.7 3.2 09/22/2004 19:10:00 4.5 0.5 6.1 3.4 4.7 0.5 6.1 3.8 0.4 0 0.4 0.4 24 6 17 305 0 0 0 0 3.2 0 3.4 3.2 09/22/2004 19:20:00 4.9 0.5 6.1 3.8 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 18 8 11 305 0 0 0 0 3.2 0 3.4 3.2 09/22/2004 19:30:00 4.8 0.5 6.5 3.8 4.9 0.6 6.5 3.8 0.4 0 0.4 0.4 17 8 21 305 0 0 0 0 3 0 3.2 2.9 09/22/2004 19:40:00 4.8 0.5 6.1 3.4 4.9 0.5 6.1 3 0.4 0 0.4 0.4 21 10 23 305 0 0 0 0 3 0 3.2 2.9 09/22/2004 19:50:00 4.9 0.7 6.8 3.4 5 0.7 6.8 3.4 0.4 0 0.4 0.4 14 6 18 305 0 0 0 0 2.9 0 3.2 2.9 09/22/2004 20:00:00 3.8 0.8 6.5 2.3 4 0.8 6.8 2.3 0.4 0 0.4 0.4 13 7 30 305 0 0 0 0 3 0.1 3.4 2.9 09/22/2004 20:10:00 3.7 0.7 6.1 2.3 4 0.7 5.7 2.6 0.4 0 0.4 0.4 22 7 21 305 0 0 0 0 2.9 0 3.4 2.9 09/22/2004 20:20:00 4 0.5 5.3 2.6 4.2 0.5 5.7 3 0.4 0 0.4 0.4 15 8 23 305 0 0 0 0 3.1 0 3.4 2.9 09/22/2004 20:30:00 4.3 0.7 5.7 2.6 4.5 0.6 5.7 3 0.4 0 0.4 0.4 20 6 19 305 0 0 0 0 3.2 0 3.4 2.9 09/22/2004 20:40:00 4.6 0.4 5.7 3.4 4.8 0.5 6.1 3.4 0.4 0 0.4 0.4 15 7 8 305 0 0 0 0 3.2 0 3.7 3.2 09/22/2004 20:50:00 4.8 0.5 5.7 3.4 5 0.5 6.1 3.4 0.4 0 0.4 0.4 8 4 13 305 0 0 0 0 3.3 0 3.7 3.2 09/22/2004 21:00:00 4.9 0.4 6.1 3.8 5.2 0.4 6.1 4.2 0.4 0 0.4 0.4 10 7 20 305 0 0 0 0 3.3 0 3.4 3.2 09/22/2004 21:10:00 5.4 0.8 6.8 3.8 5.5 0.8 7.2 4.2 0.4 0 0.4 0.4 15 5 16 305 0 0 0 0 3.2 0 3.4 3.2 09/22/2004 21:20:00 4.9 0.6 6.1 3.4 5.1 0.6 6.5 3.4 0.4 0 0.4 0.4 17 7 10 305 0 0 0 0 3.2 0.1 3.4 2.9 09/22/2004 21:30:00 4.9 0.7 6.8 3.4 5.1 0.7 7.2 3.8 0.4 0 0.4 0.4 11 6 14 305 0 0 0 0 3.1 0.1 3.4 2.9 09/22/2004 21:40:00 5.5 0.7 6.8 3.8 5.7 0.7 7.2 4.2 0.4 0 0.4 0.4 15 5 10 305 0 0 0 0 3.1 0.1 3.4 2.9 09/22/2004 21:50:00 5.6 0.6 7.2 4.2 5.9 0.7 7.6 4.2 0.4 0 0.4 0.4 9 6 11 305 0 0 0 0 3.1 0.2 3.4 2.9 09/22/2004 22:00:00 5.8 0.6 7.6 4.2 6 0.6 8 4.6 0.4 0 0.4 0.4 5 7 5 305 0 0 0 0 3.1 0.2 3.4 2.9 09/22/2004 22:10:00 5.7 0.6 7.2 4.6 5.9 0.6 7.2 4.6 0.4 0 0.4 0.4 6 7 355 305 0 0 0 0 3 0.2 3.4 2.7 09/22/2004 22:20:00 5.7 0.7 9.5 4.2 5.8 0.7 9.5 4.6 0.4 0 0.4 0.4 10 9 16 305 0 0 0 0 3 0.2 3.4 2.7 09/22/2004 22:30:00 6.7 0.9 8.8 4.6 6.9 0.9 9.5 4.9 0.4 0 0.4 0.4 9 9 16 305 0 0 0 0 2.9 0.2 3.4 2.7 09/22/2004 22:40:00 7.3 0.6 8.8 4.9 7.6 0.6 9.1 5.7 0.4 0 0.4 0.4 12 10 3 305 0 0 0 0 2.8 0.2 3.2 2.5 09/22/2004 22:50:00 7.1 0.6 8.8 5.7 7.3 0.7 9.5 6.1 0.4 0 0.4 0.4 8 5 2 305 0 0 0 0 2.7 0.1 3.2 2.5 09/22/2004 23:00:00 7.6 0.7 9.5 6.1 7.8 0.7 9.9 6.5 0.4 0 0.4 0.4 10 4 3 305 0 0 0 0 2.6 0.1 3.2 2.2 09/22/2004 23:10:00 7.3 0.7 8.8 5.7 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 12 7 0 305 0 0 0 0 2.5 0.1 2.9 2.2 09/22/2004 23:20:00 7.3 0.7 8.8 5.3 7.5 0.8 9.1 5.3 0.4 0 0.4 0.4 17 6 9 305 0 0 0 0 2.4 0.2 2.9 2.2 09/22/2004 23:30:00 7.2 0.8 9.1 4.6 7.4 0.8 9.5 4.9 0.4 0 0.4 0.4 7 6 5 305 0 0 0 0 2.5 0.2 2.9 2.2 09/22/2004 23:40:00 7.2 0.7 9.1 5.3 7.4 0.7 9.5 5.7 0.4 0 0.4 0.4 14 5 15 305 0 0 0 0 2.4 0.1 2.9 2.2 09/22/2004 23:50:00 7 0.6 8.8 5.7 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 8 7 16 305 0 0 0 0 2.4 0.1 2.9 2.2 09/23/2004 00:00:00 6.9 0.8 9.1 5.3 7.1 0.8 9.5 4.9 0.4 0 0.4 0.4 6 7 4 305 0 0 0 0 2.5 0.1 2.9 2.2 09/23/2004 00:10:00 8 0.7 9.5 6.5 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 7 6 7 305 0 0 0 0 2.6 0 2.9 2.5 09/23/2004 00:20:00 8.3 0.7 9.9 6.5 8.6 0.7 10.3 6.5 0.4 0 0.4 0.4 6 6 4 305 0 0 0 0 2.5 0.1 2.9 2.2 09/23/2004 00:30:00 8.9 0.8 11.1 6.8 9 0.8 11.1 6.1 0.4 0 0.4 0.4 15 6 9 305 0 0 0 0 2.3 0.2 2.9 2.2 09/23/2004 00:40:00 9 0.6 10.3 7.2 9.2 0.6 10.3 7.2 0.4 0 0.4 0.4 11 4 11 305 0 0 0 0 2.2 0.1 2.7 2 09/23/2004 00:50:00 8.9 0.8 11.1 6.5 9 0.8 11.5 6.8 0.4 0 0.4 0.4 10 5 14 305 0 0 0 0 2.2 0.1 2.7 2 09/23/2004 01:00:00 8.6 0.9 10.7 6.5 8.9 0.9 10.7 6.5 0.4 0 0.4 0.4 9 5 12 305 0 0 0 0 2.2 0 2.7 2 09/23/2004 01:10:00 8.8 0.8 10.7 6.8 9 0.8 11.1 6.8 0.4 0 0.4 0.4 8 5 10 305 0 0 0 0 2.1 0 2.5 2 09/23/2004 01:20:00 9.2 0.8 11.5 6.8 9.3 1 11.5 6.8 0.4 0 0.4 0.4 9 7 13 305 0 0 0 0 2.1 0 2.5 2 09/23/2004 01:30:00 9.6 0.8 11.1 6.8 9.8 0.8 11.8 7.2 0.4 0 0.4 0.4 10 5 9 305 0 0 0 0 2.2 0 2.5 2 09/23/2004 01:40:00 9.5 0.8 11.5 6.5 9.7 0.9 11.8 6.5 0.4 0 0.4 0.4 2 5 358 305 0 0 0 0 2.2 0 2.7 2 09/23/2004 01:50:00 9.2 0.7 11.5 7.2 9.4 0.8 11.8 7.6 0.4 0 0.4 0.4 6 4 6 305 0 0 0 0 2.2 0 2.7 2 09/23/2004 02:00:00 9 0.6 10.7 7.2 9.2 0.6 11.1 7.6 0.4 0 0.4 0.4 6 6 12 305 0 0 0 0 2.1 0 2.5 2 09/23/2004 02:10:00 8.9 0.7 11.1 7.2 9.1 0.8 11.1 6.8 0.4 0 0.4 0.4 9 5 9 305 0 0 0 0 2 0 2.5 2 09/23/2004 02:20:00 8.9 0.7 10.7 7.2 9.1 0.8 11.1 6.8 0.4 0 0.4 0.4 3 5 3 305 0 0 0 0 2 0 2.5 2 09/23/2004 02:30:00 8.9 0.7 10.3 6.5 9.1 0.8 10.7 6.5 0.4 0 0.4 0.4 4 5 3 305 0 0 0 0 2 0 2.5 2 09/23/2004 02:40:00 8.9 0.8 11.1 6.8 9.2 0.9 11.1 7.2 0.4 0 0.4 0.4 3 6 358 305 0 0 0 0 2 0 2.5 1.7 09/23/2004 02:50:00 8.9 0.6 10.7 7.2 9.2 0.6 11.1 7.2 0.4 0 0.4 0.4 3 6 359 305 0 0 0 0 1.9 0.1 2.5 1.7 09/23/2004 03:00:00 9 0.8 11.1 6.8 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 5 5 7 305 0 0 0 0 2 0.1 2.5 1.7 09/23/2004 03:10:00 9 0.7 10.3 6.8 9.2 0.7 10.7 6.8 0.4 0 0.4 0.4 7 5 6 305 0 0 0 0 2 0.1 2.5 2 09/23/2004 03:20:00 9.1 0.7 10.7 7.2 9.3 0.7 11.1 7.2 0.4 0 0.4 0.4 7 6 18 305 0 0 0 0 2 0.1 2.5 2 09/23/2004 03:30:00 8.9 0.8 11.1 6.8 9.1 0.9 11.5 6.1 0.4 0 0.4 0.4 4 6 9 305 0 0 0 0 2 0.1 2.5 2 09/23/2004 03:40:00 8.8 0.8 11.1 6.8 9 0.8 11.1 6.8 0.4 0 0.4 0.4 6 5 7 305 0 0 0 0 2.1 0.1 2.5 2 09/23/2004 03:50:00 9.9 0.8 11.8 7.6 10.2 0.9 11.8 7.2 0.4 0 0.4 0.4 2 4 5 305 0 0 0 0 2 0.1 2.2 1.7 09/23/2004 04:00:00 9.6 0.7 11.1 7.6 9.8 0.8 11.8 7.6 0.4 0 0.4 0.4 8 5 2 305 0 0 0 0 1.9 0 2.2 1.7 09/23/2004 04:10:00 9.7 0.7 11.8 7.6 10 0.7 11.8 8.4 0.4 0 0.4 0.4 4 5 11 305 0 0 0 0 1.9 0 2.5 1.7 09/23/2004 04:20:00 10 1 12.2 7.6 10.3 1 12.6 7.6 0.4 0 0.4 0.4 1 6 9 305 0 0 0 0 1.9 0 2.2 2 09/23/2004 04:30:00 9.5 0.7 11.5 7.6 9.7 0.8 11.5 7.6 0.4 0 0.4 0.4 4 6 10 305 0 0 0 0 1.9 0.1 2.5 1.7 09/23/2004 04:40:00 9.5 0.8 11.5 7.6 9.8 0.8 11.5 8 0.4 0 0.4 0.4 1 4 16 305 0 0 0 0 1.9 0.1 2.2 1.5 09/23/2004 04:50:00 9.5 0.8 11.8 7.6 9.7 0.9 12.2 7.6 0.4 0 0.4 0.4 9 5 0 305 0 0 0 0 1.7 0.1 2.2 1.5 09/23/2004 05:00:00 9 0.9 11.1 6.5 9.2 0.9 11.5 6.8 0.4 0 0.4 0.4 8 5 9 305 0 0 0 0 1.8 0.1 2.2 1.5 09/23/2004 05:10:00 8.8 0.7 10.7 7.2 9.1 0.7 11.1 7.2 0.4 0 0.4 0.4 6 3 3 305 0 0 0 0 1.9 0.1 2.2 1.7 09/23/2004 05:20:00 8.5 0.8 11.1 6.5 8.8 0.9 11.8 6.5 0.4 0 0.4 0.4 2 5 4 305 0 0 0 0 1.9 0.1 2.5 1.7 09/23/2004 05:30:00 8.3 1 10.7 6.1 8.5 1 10.7 6.1 0.4 0 0.4 0.4 9 5 8 305 0 0 0 0 1.9 0.1 2.2 1.7 09/23/2004 05:40:00 8.9 0.7 10.7 7.2 9.1 0.7 11.1 6.8 0.4 0 0.4 0.4 11 5 11 305 0 0 0 0 1.8 0.1 2.2 1.5 09/23/2004 05:50:00 8.9 0.8 11.1 6.5 9.1 0.8 10.7 6.8 0.4 0 0.4 0.4 9 5 14 305 0 0 0 0 1.7 0.1 2.2 1.5 09/23/2004 06:00:00 8.6 0.6 10.3 6.8 8.9 0.6 10.7 7.6 0.4 0 0.4 0.4 11 4 14 305 0 0 0 0 1.6 0 2.2 1.5 09/23/2004 06:10:00 8.5 0.7 10.3 6.5 8.6 0.8 11.1 6.5 0.4 0 0.4 0.4 9 5 5 305 0 0 0 0 1.6 0 2 1.5 09/23/2004 06:20:00 8.4 1 10.7 6.1 8.6 1 11.5 6.1 0.4 0 0.4 0.4 11 6 10 305 0 0 0 0 1.6 0 2.2 1.5 09/23/2004 06:30:00 8.3 0.7 9.9 6.8 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 5 5 3 305 0 0 0 0 1.6 0 2.2 1.5 09/23/2004 06:40:00 8 0.6 9.5 6.1 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 6 5 10 305 0 0 0 0 1.6 0 2.2 1.5 09/23/2004 06:50:00 7.9 0.6 9.5 6.1 8 0.6 9.5 6.1 0.4 0 0.4 0.4 11 7 359 305 0 0 0 0 1.6 0 2 1.5 09/23/2004 07:00:00 8.1 0.7 9.9 6.1 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 9 8 14 305 0 0 0 0 1.6 0 2 1.5 09/23/2004 07:10:00 8.4 0.6 9.9 6.1 8.6 0.6 10.3 6.5 0.4 0 0.4 0.4 6 4 13 305 0 0 0 0 1.6 0 2 1.5 09/23/2004 07:20:00 8.6 0.7 10.3 6.8 8.8 0.7 10.7 7.2 0.4 0 0.4 0.4 4 5 12 305 0 0 0 0 1.7 0.1 2.2 1.5 09/23/2004 07:30:00 8.7 0.7 11.1 6.8 8.9 0.8 11.5 6.8 0.4 0 0.4 0.4 6 6 4 305 0 0 0 0 1.8 0.1 2.2 1.5 09/23/2004 07:40:00 8.9 0.7 11.1 6.8 9.1 0.7 10.7 6.8 0.4 0 0.4 0.4 4 6 6 305 0 0 0 0 1.9 0.1 2.2 1.7 09/23/2004 07:50:00 9 0.6 11.5 7.6 9.2 0.6 11.1 7.6 0.4 0 0.4 0.4 3 5 2 305 0 0 0 0 1.9 0 2.5 1.7 09/23/2004 08:00:00 9.1 0.7 10.7 6.8 9.4 0.7 11.8 6.8 0.4 0 0.4 0.4 5 5 5 305 0 0 0 0 2 0 2.5 2 09/23/2004 08:10:00 9.2 0.6 10.7 6.8 9.4 0.7 11.1 7.2 0.4 0 0.4 0.4 5 6 13 305 0 0 0 0 2 0 2.5 2 09/23/2004 08:20:00 9.2 0.7 11.1 7.2 9.5 0.7 11.5 7.6 0.4 0 0.4 0.4 7 4 359 305 0 0 0 0 2 0 2.2 2 09/23/2004 08:30:00 9.4 0.5 11.1 8 9.5 0.6 10.7 8 0.4 0 0.4 0.4 7 4 5 305 0 0 0 0 1.9 0 2.2 1.7 09/23/2004 08:40:00 9.1 0.7 11.5 7.2 9.3 0.7 11.1 7.6 0.4 0 0.4 0.4 8 5 7 305 0 0 0 0 1.9 0.1 2.5 1.7 09/23/2004 08:50:00 9.6 0.6 11.1 7.2 9.8 0.7 11.1 7.6 0.4 0 0.4 0.4 9 4 13 305 0 0 0 0 1.8 0.1 2.2 1.5 09/23/2004 09:00:00 9.4 0.6 10.7 7.6 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 6 5 13 305 0 0 0 0 1.8 0.1 2.2 1.5 09/23/2004 09:10:00 9 0.8 11.1 7.2 9.1 0.9 11.5 6.5 0.4 0 0.4 0.4 2 4 7 305 0 0 0 0 1.8 0.1 2.2 1.5 09/23/2004 09:20:00 9.4 0.7 11.5 8 9.7 0.7 11.8 8 0.4 0 0.4 0.4 4 5 357 305 0 0 0 0 1.8 0.1 2.2 1.5 09/23/2004 09:30:00 9.3 0.7 10.7 7.6 9.5 0.7 11.5 8 0.4 0 0.4 0.4 3 5 1 305 0 0 0 0 1.9 0 2.2 1.7 09/23/2004 09:40:00 9.1 0.7 10.7 7.2 9.4 0.7 11.5 7.2 0.4 0 0.4 0.4 2 6 8 305 0 0 0 0 1.9 0 2.2 1.7 09/23/2004 09:50:00 8.7 0.7 10.3 6.8 8.9 0.7 10.3 7.2 0.4 0 0.4 0.4 0 5 2 305 0 0 0 0 1.9 0 2.2 1.7 09/23/2004 10:00:00 8.5 0.7 10.3 6.5 8.8 0.8 10.7 6.5 0.4 0 0.4 0.4 357 4 356 305 0 0 0 0 1.9 0 2.2 1.7 09/23/2004 10:10:00 8.4 0.9 10.7 6.5 8.6 1 10.7 6.1 0.4 0 0.4 0.4 358 5 0 305 0 0 0 0 1.9 0 2.5 1.7 09/23/2004 10:20:00 8.7 0.6 9.9 6.8 8.9 0.6 10.7 6.8 0.4 0 0.4 0.4 356 6 356 305 0 0 0 0 2 0 2.5 1.7 09/23/2004 10:30:00 8.2 0.6 9.9 6.5 8.4 0.7 9.9 6.5 0.4 0 0.4 0.4 359 5 358 305 0 0 0 0 2.1 0 2.5 2 09/23/2004 10:40:00 7.2 0.7 9.1 5.7 7.4 0.8 9.5 5.3 0.4 0 0.4 0.4 356 6 2 305 0 0 0 0 2.1 0 2.5 2 09/23/2004 10:50:00 7.4 0.6 8.8 5.7 7.6 0.6 9.1 5.7 0.4 0 0.4 0.4 358 7 7 305 0 0 0 0 2.2 0 2.7 2 09/23/2004 11:00:00 7.6 0.6 9.1 6.1 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 355 6 354 305 0 0 0 0 2.3 0.1 2.7 2.2 09/23/2004 11:10:00 7.1 0.7 8.4 5.7 7.4 0.7 9.1 5.3 0.4 0 0.4 0.4 355 6 349 305 0 0 0 0 2.3 0.1 2.7 2.2 09/23/2004 11:20:00 6.6 0.5 8.4 5.3 6.9 0.6 8.4 4.9 0.4 0 0.4 0.4 355 8 4 305 0 0 0 0 2.3 0.1 2.7 2.2 09/23/2004 11:30:00 7.1 0.6 8.4 5.3 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 353 6 352 305 0 0 0 0 2.4 0.2 2.9 2.2 09/23/2004 11:40:00 6.8 0.7 9.1 4.9 7 0.8 9.1 4.9 0.4 0 0.4 0.4 355 8 340 305 0 0 0 0 2.6 0.1 2.9 2.2 09/23/2004 11:50:00 7.2 0.8 9.1 5.7 7.4 0.8 9.5 5.7 0.4 0 0.4 0.4 354 5 348 305 0 0 0 0 2.5 0 2.9 2.2 09/23/2004 12:00:00 7 0.9 9.1 4.6 7.3 1 10.3 5.3 0.4 0 0.4 0.4 344 7 344 305 0 0 0 0 2.6 0 2.9 2.5 09/23/2004 12:10:00 6.4 0.6 8 4.9 6.6 0.7 8 4.9 0.4 0 0.4 0.4 348 5 339 305 0 0 0 0 2.7 0.1 3.2 2.5 09/23/2004 12:20:00 6.5 0.6 8 5.3 6.7 0.6 8 4.9 0.4 0 0.4 0.4 348 6 352 305 0 0 0 0 2.9 0.2 3.4 2.7 09/23/2004 12:30:00 6.9 0.5 8.4 5.3 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 341 6 354 305 0 0 0 0 3 0.1 3.7 2.7 09/23/2004 12:40:00 7 1 8.8 4.9 7.2 1 9.5 4.9 0.4 0 0.4 0.4 348 5 348 305 0 0 0 0 3.1 0.1 3.7 2.9 09/23/2004 12:50:00 6.9 0.6 8.8 5.3 7.1 0.5 8.8 5.3 0.4 0 0.4 0.4 347 5 347 305 0 0 0 0 3.3 0.1 3.7 3.2 09/23/2004 13:00:00 6.7 0.5 8.4 5.3 6.9 0.6 8.8 5.3 0.4 0 0.4 0.4 352 7 349 305 0 0 0 0 3.4 0.2 3.9 3.2 09/23/2004 13:10:00 7.6 0.7 9.1 5.3 7.8 0.7 9.5 5.3 0.4 0 0.4 0.4 353 6 347 305 0 0 0 0 3.3 0.3 4.2 2.7 09/23/2004 13:20:00 7 0.9 9.1 4.6 7.3 1 9.5 4.9 0.4 0 0.4 0.4 352 5 357 305 0 0 0 0 2.9 0.2 3.7 2.7 09/23/2004 13:30:00 6.8 0.6 8.4 5.3 7 0.6 8.8 5.3 0.4 0 0.4 0.4 352 7 358 305 0 0 0 0 3 0.1 3.4 2.7 09/23/2004 13:40:00 7 0.6 8.8 5.7 7.2 0.6 9.1 5.7 0.4 0 0.4 0.4 352 5 352 305 0 0 0 0 2.9 0.1 3.4 2.7 09/23/2004 13:50:00 7 0.6 8.4 5.3 7.2 0.7 9.1 5.7 0.4 0 0.4 0.4 350 5 351 305 0 0 0 0 3.1 0.2 3.9 2.7 09/23/2004 14:00:00 8 0.7 9.5 6.5 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 349 5 347 305 0 0 0 0 3.5 0.1 4.2 3.2 09/23/2004 14:10:00 8.1 0.6 9.1 6.8 8.3 0.6 9.5 6.5 0.4 0 0.4 0.4 350 6 358 305 0 0 0 0 3.3 0.1 3.9 3.2 09/23/2004 14:20:00 8.2 0.8 10.7 6.1 8.4 0.8 11.1 6.5 0.4 0 0.4 0.4 354 5 354 305 0 0 0 0 3.3 0.1 3.9 3.2 09/23/2004 14:30:00 7.9 0.8 9.5 6.1 8.2 0.9 10.3 5.7 0.4 0 0.4 0.4 355 7 357 305 0 0 0 0 3.3 0.1 3.7 2.9 09/23/2004 14:40:00 7.9 0.8 9.9 5.7 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 352 7 354 305 0 0 0 0 3.3 0.1 3.7 3.2 09/23/2004 14:50:00 7.9 1 10.3 5.3 8 1.1 10.7 5.7 0.4 0 0.4 0.4 348 6 346 305 0 0 0 0 3.6 0.2 4.2 3.2 09/23/2004 15:00:00 8.3 0.6 9.9 6.5 8.5 0.7 9.9 6.5 0.4 0 0.4 0.4 350 4 346 305 0 0 0 0 3.6 0 4.2 3.4 09/23/2004 15:10:00 8.4 0.9 10.3 6.1 8.7 1 10.7 6.5 0.4 0 0.4 0.4 347 4 343 305 0 0 0 0 3.6 0.2 4.2 3.2 09/23/2004 15:20:00 9 0.6 10.7 6.8 9.3 0.7 11.1 7.2 0.4 0 0.4 0.4 347 3 350 305 0 0 0 0 3.5 0.2 4.4 3.2 09/23/2004 15:30:00 7.7 0.7 9.1 5.3 7.9 0.8 9.5 5.7 0.4 0 0.4 0.4 350 6 343 305 0 0 0 0 3.6 0.2 4.4 3.2 09/23/2004 15:40:00 7.9 0.9 9.9 5.7 8.1 1 10.3 6.1 0.4 0 0.4 0.4 354 7 359 305 0 0 0 0 3.9 0.1 4.4 3.7 09/23/2004 15:50:00 7.9 0.8 9.9 6.1 8.2 0.9 11.1 6.1 0.4 0 0.4 0.4 354 5 348 305 0 0 0 0 4 0.2 4.7 3.7 09/23/2004 16:00:00 8.3 0.6 9.9 6.5 8.5 0.6 10.3 6.8 0.4 0 0.4 0.4 353 6 357 305 0 0 0 0 4 0.2 4.7 3.7 09/23/2004 16:10:00 8.2 1 10.3 6.1 8.5 1 11.1 6.1 0.4 0 0.4 0.4 354 5 356 305 0 0 0 0 4.1 0.1 4.7 3.7 09/23/2004 16:20:00 8.4 0.7 10.3 6.8 8.6 0.7 10.7 7.2 0.4 0 0.4 0.4 353 5 357 305 0 0 0 0 3.9 0.1 4.4 3.7 09/23/2004 16:30:00 8.1 0.8 9.9 5.7 8.3 0.7 10.3 6.1 0.4 0 0.4 0.4 356 5 354 305 0 0 0 0 4 0.2 4.7 3.7 09/23/2004 16:40:00 8.7 0.7 10.7 6.8 8.9 0.8 10.7 6.5 0.4 0 0.4 0.4 3 5 10 305 0 0 0 0 4.3 0 4.7 4.2 09/23/2004 16:50:00 9.4 0.7 11.8 7.2 9.7 0.8 11.5 7.2 0.4 0 0.4 0.4 1 6 2 305 0 0 0 0 4.3 0.1 4.9 4.2 09/23/2004 17:00:00 9.2 0.8 11.5 7.2 9.3 0.9 11.5 6.8 0.4 0 0.4 0.4 3 5 2 305 0 0 0 0 4.2 0.2 4.9 3.9 09/23/2004 17:10:00 8.8 0.7 10.7 6.8 8.9 0.7 10.7 6.8 0.4 0 0.4 0.4 4 4 0 305 0 0 0 0 4.2 0.2 4.9 3.9 09/23/2004 17:20:00 9 0.6 10.7 6.8 9.1 0.7 10.7 6.8 0.4 0 0.4 0.4 4 5 359 305 0 0 0 0 4.1 0.1 4.7 3.9 09/23/2004 17:30:00 9 0.6 10.7 7.2 9.2 0.6 11.1 7.2 0.4 0 0.4 0.4 6 4 4 305 0 0 0 0 4.1 0.1 4.7 3.9 09/23/2004 17:40:00 9.7 0.5 11.1 8.4 9.8 0.6 11.1 8.4 0.4 0 0.4 0.4 8 5 12 305 0 0 0 0 4 0.2 4.4 3.9 09/23/2004 17:50:00 9.7 0.6 11.5 8 9.9 0.7 11.8 8 0.4 0 0.4 0.4 9 4 5 305 0 0 0 0 4.2 0.2 4.7 3.9 09/23/2004 18:00:00 9.7 0.8 11.5 7.6 9.8 0.9 11.8 8 0.4 0 0.4 0.4 2 5 1 305 0 0 0 0 4.2 0.1 4.7 3.9 09/23/2004 18:10:00 10.4 0.8 12.6 8.8 10.6 0.8 13 8.8 0.4 0 0.4 0.4 3 4 359 305 0 0 0 0 4 0.1 4.7 3.7 09/23/2004 18:20:00 10.5 0.6 11.8 8 10.7 0.7 12.6 8.4 0.4 0 0.4 0.4 2 6 356 305 0 0 0 0 3.9 0.1 4.4 3.7 09/23/2004 18:30:00 10.7 0.8 12.6 8.8 10.9 0.8 13 8.4 0.4 0 0.4 0.4 2 4 0 305 0 0 0 0 4 0.1 4.4 3.7 09/23/2004 18:40:00 10.7 0.6 12.2 8.8 10.9 0.6 12.6 8.8 0.4 0 0.4 0.4 6 4 10 305 0 0 0 0 4 0.1 4.4 3.7 09/23/2004 18:50:00 10.6 0.8 12.2 8.4 10.8 0.9 12.6 8.8 0.4 0 0.4 0.4 8 4 5 305 0 0 0 0 3.9 0.1 4.4 3.7 09/23/2004 19:00:00 10.5 0.7 12.2 8.8 10.7 0.8 12.6 8.4 0.4 0 0.4 0.4 0 4 1 305 0 0 0 0 3.9 0.1 4.4 3.7 09/23/2004 19:10:00 11.5 0.9 13.3 9.1 11.6 1 13.7 9.1 0.4 0 0.4 0.4 2 4 3 305 0 0 0 0 3.9 0.1 4.4 3.7 09/23/2004 19:20:00 12.2 1 14.1 9.9 12.5 1 14.5 9.5 0.4 0 0.4 0.4 0 4 356 305 0 0 0 0 3.8 0.1 4.4 3.7 09/23/2004 19:30:00 12.1 0.9 14.1 9.5 12.2 1 14.1 9.1 0.4 0 0.4 0.4 1 5 7 305 0 0 0 0 3.8 0.1 4.4 3.7 09/23/2004 19:40:00 13 0.9 15.3 10.7 13.2 1 15.3 10.3 0.4 0 0.4 0.4 358 5 1 305 0 0 0 0 3.7 0 4.2 3.4 09/23/2004 19:50:00 13 1.1 15.3 9.5 13.1 1.3 15.6 9.5 0.4 0 0.4 0.4 359 5 355 305 0 0 0 0 3.5 0.1 4.2 3.2 09/23/2004 20:00:00 12.5 0.9 14.1 9.9 12.8 1 14.9 9.9 0.4 0 0.4 0.4 356 4 353 305 0 0 0 0 3.3 0.1 3.7 3.2 09/23/2004 20:10:00 13 0.8 15.3 10.3 13.2 1 15.6 10.3 0.4 0 0.4 0.4 357 5 356 305 0 0 0 0 3.2 0.1 3.7 2.9 09/23/2004 20:20:00 13.1 1.1 15.3 9.1 13.2 1.2 15.3 9.1 0.4 0 0.4 0.4 359 3 1 305 0 0 0 0 3.2 0.1 3.7 2.9 09/23/2004 20:30:00 13.3 1.2 15.6 9.5 13.3 1.3 15.6 9.9 0.4 0 0.4 0.4 4 5 7 305 0 0 0 0 3 0.2 3.7 2.7 09/23/2004 20:40:00 14.1 1.1 16.4 10.7 14.2 1.2 16.8 10.7 0.4 0 0.4 0.4 4 4 5 305 0 0 0 0 3.1 0.2 3.4 2.9 09/23/2004 20:50:00 14 0.9 16.1 11.5 14.1 1 16.1 10.7 0.4 0 0.4 0.4 2 5 0 305 0 0 0 0 3 0.1 3.4 2.9 09/23/2004 21:00:00 14.1 1 17.6 9.5 14.2 1.1 17.2 10.3 0.4 0 0.4 0.4 359 4 4 305 0 0 0 0 3 0.1 3.4 2.7 09/23/2004 21:10:00 14.4 0.9 16.4 11.1 14.5 1 16.8 10.7 0.4 0 0.4 0.4 2 5 12 305 0 0 0 0 2.8 0.1 3.2 2.7 09/23/2004 21:20:00 13.7 0.9 15.6 10.7 13.8 1 16.1 11.1 0.4 0 0.4 0.4 354 4 349 305 0 0 0 0 2.8 0.1 3.2 2.7 09/23/2004 21:30:00 13.9 1 16.8 10.3 14.2 1 16.4 10.3 0.4 0 0.4 0.4 359 4 359 305 0 0 0 0 2.7 0 3.2 2.5 09/23/2004 21:40:00 13.6 1.1 16.4 10.7 13.9 1.1 16.4 11.1 0.4 0 0.4 0.4 358 5 354 305 0 0 0 0 2.7 0.1 3.2 2.5 09/23/2004 21:50:00 11 1.1 13.3 8.4 11.2 1.2 13.7 8.4 0.4 0 0.4 0.4 355 6 355 305 0 0 0 0 2.7 0.1 3.2 2.5 09/23/2004 22:00:00 12.2 1 14.5 9.1 12.3 1.1 14.9 9.5 0.4 0 0.4 0.4 352 6 356 305 0 0 0 0 2.7 0 3.2 2.5 09/23/2004 22:10:00 12 0.9 14.1 8.8 12.2 1 14.5 9.1 0.4 0 0.4 0.4 348 5 345 305 0 0 0 0 2.6 0 3.2 2.5 09/23/2004 22:20:00 11.8 1 13.7 9.5 12.1 1 14.5 9.5 0.4 0 0.4 0.4 354 4 357 305 0 0 0 0 2.7 0 3.2 2.5 09/23/2004 22:30:00 11.8 1.2 14.5 8.8 12 1.2 14.9 8.4 0.4 0 0.4 0.4 349 5 347 305 0 0 0 0 2.7 0 3.2 2.5 09/23/2004 22:40:00 12.4 1.1 15.3 9.5 12.6 1.2 15.6 9.5 0.4 0 0.4 0.4 356 5 355 305 0 0 0 0 2.7 0 3.2 2.5 09/23/2004 22:50:00 12.4 0.9 14.1 10.3 12.6 0.9 14.5 9.9 0.4 0 0.4 0.4 356 4 358 305 0 0 0 0 2.7 0 3.2 2.7 09/23/2004 23:00:00 12.2 0.8 13.7 10.3 12.4 0.8 14.9 10.3 0.4 0 0.4 0.4 355 4 356 305 0 0 0 0 2.7 0 3.2 2.5 09/23/2004 23:10:00 13.2 0.8 15.3 11.1 13.4 0.9 16.1 11.1 0.4 0 0.4 0.4 350 3 352 305 0 0 0 0 2.6 0 2.9 2.5 09/23/2004 23:20:00 13.3 0.8 15.6 11.5 13.5 0.9 16.1 11.1 0.4 0 0.4 0.4 354 4 351 305 0 0 0 0 2.5 0 2.9 2.2 09/23/2004 23:30:00 12.4 0.8 14.1 9.9 12.6 1 14.5 9.5 0.4 0 0.4 0.4 350 5 355 305 0 0 0 0 2.5 0.1 2.9 2.2 09/23/2004 23:40:00 12.2 0.8 14.1 9.5 12.4 0.9 14.5 9.9 0.4 0 0.4 0.4 353 4 354 305 0 0 0 0 2.5 0 2.9 2.5 09/23/2004 23:50:00 12.3 1.1 14.9 9.5 12.5 1.2 14.9 9.1 0.4 0 0.4 0.4 353 3 355 305 0 0 0 0 2.5 0 2.9 2.2 09/24/2004 00:00:00 12.8 1.1 16.1 10.3 13.1 1.1 16.1 10.3 0.4 0 0.4 0.4 350 5 342 305 0 0 0 0 2.5 0 2.9 2.5 09/24/2004 00:10:00 11.9 1.1 14.9 9.1 12.2 1.1 15.6 9.5 0.4 0 0.4 0.4 355 4 353 305 0 0 0 0 2.6 0 3.2 2.5 09/24/2004 00:20:00 12 1 14.5 9.1 12.2 1 15.3 9.5 0.4 0 0.4 0.4 349 6 355 305 0 0 0 0 2.5 0 2.9 2.5 09/24/2004 00:30:00 11.2 1.1 13.3 8 11.4 1.2 14.1 8 0.4 0 0.4 0.4 352 6 355 305 0 0 0 0 2.5 0 2.9 2.5 09/24/2004 00:40:00 12.3 1.2 14.5 8.8 12.4 1.2 14.9 9.5 0.4 0 0.4 0.4 352 5 358 305 0 0 0 0 2.5 0 2.9 2.5 09/24/2004 00:50:00 12.6 1 14.5 9.5 12.8 1 14.9 9.9 0.4 0 0.4 0.4 349 5 344 305 0 0 0 0 2.4 0.1 2.7 2.2 09/24/2004 01:00:00 12.1 1 13.7 9.1 12.3 1 14.5 9.5 0.4 0 0.4 0.4 352 5 353 305 0 0 0 0 2.4 0 2.7 2.2 09/24/2004 01:10:00 12.7 1 15.3 9.9 13 1.1 15.6 10.3 0.4 0 0.4 0.4 355 4 359 305 0 0 0 0 2.5 0 2.9 2.2 09/24/2004 01:20:00 12.1 1.1 14.5 9.1 12.4 1.1 14.9 9.1 0.4 0 0.4 0.4 355 6 1 305 0 0 0 0 2.5 0 2.9 2.2 09/24/2004 01:30:00 11.7 1.1 14.1 8.4 12 1.1 14.9 9.1 0.4 0 0.4 0.4 347 5 349 305 0 0 0 0 2.3 0.1 2.7 2.2 09/24/2004 01:40:00 11.2 1.1 13.3 8 11.3 1.1 13.7 8.4 0.4 0 0.4 0.4 351 5 355 305 0 0 0 0 2.3 0.1 2.7 2.2 09/24/2004 01:50:00 11.1 0.9 13.3 8.8 11.2 1 14.1 8.4 0.4 0 0.4 0.4 358 5 353 305 0 0 0 0 2.4 0.1 2.9 2.2 09/24/2004 02:00:00 11 1.1 13.7 7.2 11.2 1.1 14.1 8 0.4 0 0.4 0.4 0 5 3 305 0 0 0 0 2.5 0 2.9 2.2 09/24/2004 02:10:00 12 1.1 14.9 9.1 12.1 1.2 14.9 8.8 0.4 0 0.4 0.4 356 6 350 305 0 0 0 0 2.4 0.1 2.9 2.2 09/24/2004 02:20:00 12.3 1.1 14.5 9.9 12.5 1.1 14.9 9.9 0.4 0 0.4 0.4 355 6 357 305 0 0 0 0 2.3 0.1 2.7 2.2 09/24/2004 02:30:00 12.5 0.9 14.5 9.9 12.6 1 15.3 9.9 0.4 0 0.4 0.4 355 6 7 305 0 0 0 0 2.3 0.1 2.7 2.2 09/24/2004 02:40:00 12.6 0.8 14.1 10.3 12.8 0.9 14.5 10.3 0.4 0 0.4 0.4 354 4 354 305 0 0 0 0 2.2 0.1 2.7 2.2 09/24/2004 02:50:00 12.1 1.1 14.5 9.1 12.3 1.1 15.3 8.8 0.4 0 0.4 0.4 354 4 1 305 0 0 0 0 2.2 0.1 2.7 2.2 09/24/2004 03:00:00 11.4 1 13.7 8.8 11.6 1 14.1 8.8 0.4 0 0.4 0.4 353 6 353 305 0 0 0 0 2.2 0 2.5 2 09/24/2004 03:10:00 11.6 1.2 14.1 8.4 11.9 1.2 14.9 8.8 0.4 0 0.4 0.4 353 5 353 305 0 0 0 0 2.2 0 2.5 2.2 09/24/2004 03:20:00 13.1 1.2 16.4 9.9 13.4 1.2 16.4 9.5 0.4 0 0.4 0.4 355 5 1 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 03:30:00 14 1 16.8 11.5 14.2 1.1 17.2 11.1 0.4 0 0.4 0.4 357 4 357 305 0 0 0 0 2 0 2.5 2 09/24/2004 03:40:00 13.6 1.1 16.4 10.7 13.7 1.2 17.2 9.9 0.4 0 0.4 0.4 352 5 347 305 0 0 0 0 2 0.1 2.5 1.7 09/24/2004 03:50:00 13.9 1 16.4 11.1 14 1 17.2 9.9 0.4 0 0.4 0.4 353 4 341 305 0 0 0 0 1.9 0 2.2 1.7 09/24/2004 04:00:00 13.1 1 16.1 10.7 13.3 1.1 16.1 9.5 0.4 0 0.4 0.4 354 5 353 305 0 0 0 0 1.9 0 2.2 1.7 09/24/2004 04:10:00 13.2 1 15.3 10.7 13.4 1.1 16.1 10.3 0.4 0 0.4 0.4 358 5 355 305 0 0 0 0 2 0 2.5 2 09/24/2004 04:20:00 14.2 1.2 17.6 11.1 14.4 1.2 17.6 10.7 0.4 0 0.4 0.4 357 4 353 305 0 0 0 0 1.9 0 2.5 2 09/24/2004 04:30:00 14.7 1.2 17.2 11.1 14.9 1.2 17.6 11.8 0.4 0 0.4 0.4 357 4 356 305 0 0 0 0 1.9 0.1 2.2 1.7 09/24/2004 04:40:00 13 1 15.3 10.3 13.2 1.1 15.6 9.9 0.4 0 0.4 0.4 0 5 6 305 0 0 0 0 1.9 0 2.5 1.7 09/24/2004 04:50:00 14.5 1.2 17.2 10.7 14.8 1.3 17.6 10.7 0.4 0 0.4 0.4 356 4 359 305 0 0 0 0 2 0 2.5 2 09/24/2004 05:00:00 14.3 1 16.8 11.8 14.5 1.2 17.2 11.5 0.4 0 0.4 0.4 354 6 346 305 0 0 0 0 1.8 0.1 2.2 1.5 09/24/2004 05:10:00 13.3 1.1 16.1 10.3 13.6 1.1 16.4 10.7 0.4 0 0.4 0.4 359 5 352 305 0 0 0 0 1.7 0.1 2.2 1.5 09/24/2004 05:20:00 12.2 0.8 14.1 9.9 12.3 0.9 14.5 10.3 0.4 0 0.4 0.4 357 6 0 305 0 0 0 0 1.7 0.1 2.2 1.5 09/24/2004 05:30:00 11.9 1.1 14.9 9.5 12 1.2 15.3 8.8 0.4 0 0.4 0.4 358 6 358 305 0 0 0 0 1.9 0.1 2.2 1.5 09/24/2004 05:40:00 12 1 15.6 9.1 12.3 1 15.6 9.9 0.4 0 0.4 0.4 357 6 356 305 0 0 0 0 1.8 0.1 2.2 1.5 09/24/2004 05:50:00 12.7 1.5 16.1 9.5 13 1.5 16.8 9.5 0.4 0 0.4 0.4 357 8 357 305 0 0 0 0 1.8 0.1 2.2 1.5 09/24/2004 06:00:00 13.9 1.1 16.4 10.7 14.1 1.2 17.2 11.5 0.4 0 0.4 0.4 350 4 357 305 0 0 0 0 1.8 0.1 2.2 1.5 09/24/2004 06:10:00 13.3 1.2 16.1 10.3 13.5 1.3 16.8 10.7 0.4 0 0.4 0.4 356 5 356 305 0 0 0 0 1.9 0.1 2.2 1.5 09/24/2004 06:20:00 14 1.2 16.8 10.7 14.2 1.3 17.2 11.1 0.4 0 0.4 0.4 357 7 358 305 0 0 0 0 1.9 0.1 2.5 1.5 09/24/2004 06:30:00 12.6 1.2 15.3 9.9 12.8 1.2 15.6 9.9 0.4 0 0.4 0.4 0 4 0 305 0 0 0 0 1.8 0.1 2.2 1.5 09/24/2004 06:40:00 11.5 1.2 14.5 8 11.7 1.1 14.5 7.6 0.4 0 0.4 0.4 358 6 353 305 0 0 0 0 1.8 0.1 2.2 1.5 09/24/2004 06:50:00 10.9 0.8 13 8.8 11.2 0.9 13.7 9.1 0.4 0 0.4 0.4 358 7 355 305 0 0 0 0 1.7 0.1 2.2 1.5 09/24/2004 07:00:00 11.1 1 13.3 8.4 11.2 1.1 13.7 8.8 0.4 0 0.4 0.4 359 6 2 305 0 0 0 0 1.7 0.1 2.2 1.5 09/24/2004 07:10:00 11.1 1 14.5 8.8 11.3 1.1 14.1 8.4 0.4 0 0.4 0.4 359 6 359 305 0 0 0 0 1.9 0.1 2.2 1.5 09/24/2004 07:20:00 12.4 1.2 14.9 8.8 12.7 1.3 15.3 9.1 0.4 0 0.4 0.4 0 5 1 305 0 0 0 0 1.8 0.1 2.2 1.5 09/24/2004 07:30:00 12.1 1.5 15.6 8.4 12.3 1.6 16.1 8 0.4 0 0.4 0.4 3 5 359 305 0 0 0 0 1.8 0.1 2.2 1.5 09/24/2004 07:40:00 11.6 1.1 14.5 8.8 11.7 1.2 14.9 9.1 0.4 0 0.4 0.4 0 5 0 305 0 0 0 0 1.9 0 2.2 1.7 09/24/2004 07:50:00 11 1.1 15.3 8.4 11.1 1.2 15.6 8 0.4 0 0.4 0.4 355 6 0 305 0 0 0 0 1.8 0.1 2.2 1.5 09/24/2004 08:00:00 10.6 0.8 13 8.4 10.7 0.9 13 8.4 0.4 0 0.4 0.4 0 6 354 305 0 0 0 0 1.7 0.1 2.2 1.5 09/24/2004 08:10:00 10.3 1 13.3 7.6 10.4 1.1 13.7 8 0.4 0 0.4 0.4 0 5 3 305 0 0 0 0 1.7 0.1 2.2 1.5 09/24/2004 08:20:00 10.7 1.1 13.3 8 10.9 1.2 13 7.6 0.4 0 0.4 0.4 358 6 340 305 0 0 0 0 1.7 0.1 2.2 1.5 09/24/2004 08:30:00 10.2 1 13.3 8 10.5 1 13.7 8 0.4 0 0.4 0.4 356 6 355 305 0 0 0 0 1.8 0.1 2.2 1.5 09/24/2004 08:40:00 9.9 0.8 12.2 8 10.1 0.9 12.6 7.6 0.4 0 0.4 0.4 356 6 357 305 0 0 0 0 1.8 0.1 2.5 1.5 09/24/2004 08:50:00 10.4 1.2 13 7.6 10.6 1.1 13 7.6 0.4 0 0.4 0.4 353 7 343 305 0 0 0 0 1.8 0.1 2.5 1.5 09/24/2004 09:00:00 10.5 1 13 8 10.7 1.1 13.3 8 0.4 0 0.4 0.4 351 4 349 305 0 0 0 0 1.8 0.1 2.2 1.5 09/24/2004 09:10:00 10.3 0.7 12.2 8 10.5 0.7 11.8 8.4 0.4 0 0.4 0.4 358 5 1 305 0 0 0 0 1.9 0 2.5 1.7 09/24/2004 09:20:00 10.9 1.1 17.2 8.8 11.1 1.1 15.6 9.1 0.4 0 0.4 0.4 357 6 352 305 0 0 0 0 2 0 2.5 2 09/24/2004 09:30:00 11.2 1 13.7 8.8 11.5 1.1 14.1 9.1 0.4 0 0.4 0.4 355 6 352 305 0 0 0 0 1.9 0.1 2.2 1.7 09/24/2004 09:40:00 11.2 1.1 13.7 8.4 11.5 1.1 13.7 8.8 0.4 0 0.4 0.4 351 5 1 305 0 0 0 0 2 0 2.5 2 09/24/2004 09:50:00 11.7 0.9 14.1 9.1 11.9 1 14.5 9.5 0.4 0 0.4 0.4 350 8 341 305 0 0 0 0 2 0.1 2.5 2 09/24/2004 10:00:00 11.1 0.9 12.6 8.8 11.3 1 13.3 8.8 0.4 0 0.4 0.4 349 5 346 305 0 0 0 0 1.9 0 2.2 1.7 09/24/2004 10:10:00 10.3 0.9 12.6 8 10.6 0.9 12.6 8.4 0.4 0 0.4 0.4 355 6 4 305 0 0 0 0 1.9 0.1 2.2 1.5 09/24/2004 10:20:00 11.5 0.9 14.1 9.5 11.7 1 14.1 9.1 0.4 0 0.4 0.4 0 6 3 305 0 0 0 0 1.9 0.1 2.5 1.7 09/24/2004 10:30:00 11.3 1.1 13.7 8.8 11.6 1.2 14.1 9.1 0.4 0 0.4 0.4 359 6 358 305 0 0 0 0 1.9 0.1 2.5 1.7 09/24/2004 10:40:00 10.2 1 12.6 7.2 10.3 1.1 13 7.2 0.4 0 0.4 0.4 356 6 358 305 0 0 0 0 2 0.1 2.5 1.7 09/24/2004 10:50:00 10.7 1.2 13.7 7.6 11 1.2 14.1 7.6 0.4 0 0.4 0.4 355 6 358 305 0 0 0 0 1.9 0 2.2 1.7 09/24/2004 11:00:00 11.8 0.8 13.7 9.5 12.3 0.9 14.1 9.5 0.4 0 0.4 0.4 354 4 351 305 0 0 0 0 1.9 0.1 2.2 1.5 09/24/2004 11:10:00 11.8 0.9 14.1 9.1 12 1 14.1 9.5 0.4 0 0.4 0.4 358 6 9 305 0 0 0 0 2 0 2.5 1.7 09/24/2004 11:20:00 12 1 14.5 9.5 12.2 1.1 15.3 9.5 0.4 0 0.4 0.4 358 5 353 305 0 0 0 0 2 0 2.5 2 09/24/2004 11:30:00 11.2 0.8 13.3 9.1 11.4 0.9 13.7 8.8 0.4 0 0.4 0.4 353 6 350 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 11:40:00 11.5 1.4 14.5 8 11.8 1.5 14.9 8.4 0.4 0 0.4 0.4 357 5 354 305 0 0 0 0 2.1 0.1 2.5 2 09/24/2004 11:50:00 12.6 1.1 14.9 9.1 12.9 1.1 15.3 9.5 0.4 0 0.4 0.4 355 6 1 305 0 0 0 0 2 0 2.5 2 09/24/2004 12:00:00 12.4 0.9 14.5 9.9 12.7 1 14.9 9.9 0.4 0 0.4 0.4 0 5 359 305 0 0 0 0 2 0 2.5 2 09/24/2004 12:10:00 11.8 1.1 13.7 8.8 11.9 1.2 14.1 8 0.4 0 0.4 0.4 2 6 5 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 12:20:00 11.6 1.1 13.7 8.8 11.8 1.2 14.5 8.4 0.4 0 0.4 0.4 355 4 354 305 0 0 0 0 2 0 2.5 2 09/24/2004 12:30:00 11.2 1 13.7 8.4 11.4 1 14.1 8.8 0.4 0 0.4 0.4 358 4 359 305 0 0 0 0 2 0 2.5 1.7 09/24/2004 12:40:00 10.9 0.8 12.6 8.8 11.1 0.9 13.3 8.4 0.4 0 0.4 0.4 351 7 357 305 0 0 0 0 1.9 0 2.5 1.7 09/24/2004 12:50:00 9.6 1 12.6 7.2 9.8 1 13 6.8 0.4 0 0.4 0.4 347 6 348 305 0 0 0 0 1.9 0.1 2.5 1.5 09/24/2004 13:00:00 10.2 0.8 12.2 8 10.5 0.9 12.6 7.6 0.4 0 0.4 0.4 353 5 352 305 0 0 0 0 1.9 0 2.5 2 09/24/2004 13:10:00 10.9 0.7 13.3 8.8 11.1 0.8 13.3 8.8 0.4 0 0.4 0.4 0 6 1 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 13:20:00 10.3 1 12.6 7.6 10.6 1.1 13 8 0.4 0 0.4 0.4 357 6 6 305 0 0 0 0 2 0 2.5 2 09/24/2004 13:30:00 9.9 0.8 11.8 7.6 10.1 0.9 12.2 8 0.4 0 0.4 0.4 348 8 4 305 0 0 0 0 2 0 2.5 1.7 09/24/2004 13:40:00 9.5 1 11.8 7.2 9.7 1 11.8 6.5 0.4 0 0.4 0.4 351 7 353 305 0 0 0 0 2.2 0.1 2.7 2 09/24/2004 13:50:00 9.2 0.9 11.8 7.2 9.4 1 12.2 7.2 0.4 0 0.4 0.4 357 6 349 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 14:00:00 9.7 1.1 13 7.2 9.9 1.1 13.3 6.8 0.4 0 0.4 0.4 349 7 351 305 0 0 0 0 2 0 2.5 2 09/24/2004 14:10:00 9.6 1.1 12.2 7.2 9.8 1.1 12.6 7.2 0.4 0 0.4 0.4 345 6 348 305 0 0 0 0 2 0 2.5 2 09/24/2004 14:20:00 9 1.1 11.8 6.5 9.2 1.2 13 6.5 0.4 0 0.4 0.4 350 5 346 305 0 0 0 0 2 0.1 2.5 2 09/24/2004 14:30:00 9.2 1 11.8 6.5 9.4 1.1 12.6 7.2 0.4 0 0.4 0.4 354 6 1 305 0 0 0 0 2 0.1 2.7 2 09/24/2004 14:40:00 8.9 1 11.5 6.8 9.1 1 11.5 6.8 0.4 0 0.4 0.4 352 5 358 305 0 0 0 0 2.2 0 2.5 2 09/24/2004 14:50:00 8 1 11.5 5.7 8 1.1 11.8 4.9 0.4 0 0.4 0.4 352 7 1 305 0 0 0 0 2.1 0.1 2.5 2 09/24/2004 15:00:00 9.3 1 11.5 7.2 9.6 1 12.2 7.2 0.4 0 0.4 0.4 351 5 352 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 15:10:00 9.5 0.7 11.5 8 9.7 0.7 12.2 8.4 0.4 0 0.4 0.4 355 7 347 305 0 0 0 0 2.1 0.1 2.7 2 09/24/2004 15:20:00 9.1 0.7 11.1 7.6 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 351 7 342 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 15:30:00 9.4 0.9 11.8 6.8 9.6 0.9 12.2 6.8 0.4 0 0.4 0.4 356 7 353 305 0 0 0 0 2.1 0.1 2.7 2 09/24/2004 15:40:00 8.2 1 11.5 6.1 8.4 1 12.2 6.5 0.4 0 0.4 0.4 357 7 1 305 0 0 0 0 2.1 0.1 2.5 2 09/24/2004 15:50:00 8.5 0.8 11.1 6.8 8.8 0.9 11.1 6.5 0.4 0 0.4 0.4 355 8 3 305 0 0 0 0 2 0 2.5 1.7 09/24/2004 16:00:00 8.1 0.9 11.1 6.1 8.3 0.9 11.1 6.1 0.4 0 0.4 0.4 347 8 353 305 0 0 0 0 2 0 2.5 2 09/24/2004 16:10:00 9.1 1.1 11.8 6.1 9.3 1.2 11.8 6.5 0.4 0 0.4 0.4 354 8 356 305 0 0 0 0 2 0.1 2.5 1.7 09/24/2004 16:20:00 9.3 0.9 11.5 7.2 9.5 0.9 11.5 7.2 0.4 0 0.4 0.4 349 6 1 305 0 0 0 0 2 0 2.5 2 09/24/2004 16:30:00 8.7 1 11.1 6.5 8.9 1 11.5 6.5 0.4 0 0.4 0.4 0 6 356 305 0 0 0 0 2.2 0.1 2.7 2 09/24/2004 16:40:00 7.9 1 9.9 5.3 8.1 1 10.3 5.3 0.4 0 0.4 0.4 354 5 353 305 0 0 0 0 2 0 2.5 2 09/24/2004 16:50:00 8.3 1 10.3 4.6 8.4 1.1 10.7 4.2 0.4 0 0.4 0.4 355 7 354 305 0 0 0 0 1.9 0 2.5 1.7 09/24/2004 17:00:00 8.6 0.7 10.3 6.5 8.8 0.8 10.7 6.5 0.4 0 0.4 0.4 343 10 339 305 0 0 0 0 2 0 2.5 1.7 09/24/2004 17:10:00 7.8 1.3 10.7 4.9 8 1.2 10.7 4.9 0.4 0 0.4 0.4 352 5 350 305 0 0 0 0 2 0 2.5 2 09/24/2004 17:20:00 8.4 1.1 11.5 6.1 8.7 1.1 11.8 6.1 0.4 0 0.4 0.4 356 6 358 305 0 0 0 0 2 0 2.5 2 09/24/2004 17:30:00 7.6 1 10.3 5.7 7.7 1 10.7 5.3 0.4 0 0.4 0.4 355 5 357 305 0 0 0 0 2 0 2.5 2 09/24/2004 17:40:00 7.3 1 9.5 5.7 7.6 1.1 9.9 5.7 0.4 0 0.4 0.4 350 5 345 305 0 0 0 0 2 0 2.5 2 09/24/2004 17:50:00 7.3 0.8 9.5 5.3 7.5 0.9 9.5 5.3 0.4 0 0.4 0.4 358 5 358 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 18:00:00 7.5 0.8 9.1 5.7 7.7 0.8 9.9 5.7 0.4 0 0.4 0.4 348 7 339 305 0 0 0 0 2.2 0 2.7 2 09/24/2004 18:10:00 7.3 1 9.5 5.3 7.5 1 10.3 5.3 0.4 0 0.4 0.4 352 7 356 305 0 0 0 0 2.2 0 2.7 2 09/24/2004 18:20:00 7.3 0.8 9.9 5.3 7.5 0.9 9.9 5.3 0.4 0 0.4 0.4 344 9 350 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 18:30:00 6.5 0.8 9.9 4.6 6.6 0.8 9.1 4.9 0.4 0 0.4 0.4 338 10 344 305 0 0 0 0 2.2 0 2.7 2 09/24/2004 18:40:00 6.8 0.7 8.8 4.9 7 0.7 8.8 5.3 0.4 0 0.4 0.4 346 7 343 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 18:50:00 6.3 1.2 9.5 4.2 6.5 1.2 9.5 4.2 0.4 0 0.4 0.4 344 9 336 305 0 0 0 0 2 0 2.5 2 09/24/2004 19:00:00 6.3 0.9 9.1 4.2 6.5 0.9 8.8 4.2 0.4 0 0.4 0.4 343 9 328 305 0 0 0 0 2 0 2.5 2 09/24/2004 19:10:00 6.5 0.9 8.8 4.2 6.8 1 9.1 4.6 0.4 0 0.4 0.4 344 8 346 305 0 0 0 0 2.2 0.1 2.5 2 09/24/2004 19:20:00 6.3 0.8 8.4 4.6 6.5 0.8 8.8 4.6 0.4 0 0.4 0.4 342 5 336 305 0 0 0 0 2.2 0.1 2.5 2 09/24/2004 19:30:00 6.4 0.7 8.4 4.6 6.6 0.8 8.4 4.9 0.4 0 0.4 0.4 345 8 343 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 19:40:00 6.3 0.8 9.1 4.6 6.5 0.8 9.5 4.9 0.4 0 0.4 0.4 343 7 341 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 19:50:00 6 1 8.4 4.2 6.2 1 8 4.2 0.4 0 0.4 0.4 359 5 3 305 0 0 0 0 2 0 2.5 2 09/24/2004 20:00:00 6.7 0.8 9.1 4.9 6.9 0.9 8.8 4.6 0.4 0 0.4 0.4 359 7 356 305 0 0 0 0 2.1 0 2.5 2 09/24/2004 20:10:00 5.4 0.7 7.2 4.2 5.6 0.7 7.6 3.8 0.4 0 0.4 0.4 352 9 346 305 0 0 0 0 2 0 2.5 2 09/24/2004 20:20:00 6 1.1 8.8 3.8 6.2 1.1 8.8 3.8 0.4 0 0.4 0.4 349 11 339 305 0 0 0 0 2 0 2.5 2 09/24/2004 20:30:00 5 0.7 6.8 3.4 5.2 0.7 7.6 3.8 0.4 0 0.4 0.4 355 9 359 305 0 0 0 0 2 0 2.5 2 09/24/2004 20:40:00 5.3 1.1 7.6 3 5.4 1.2 8 3 0.4 0 0.4 0.4 350 7 348 305 0 0 0 0 2 0.1 2.5 2 09/24/2004 20:50:00 5.6 0.7 7.6 3.8 5.8 0.8 7.6 4.2 0.4 0 0.4 0.4 346 11 351 305 0 0 0 0 2 0 2.5 2 09/24/2004 21:00:00 5.6 0.9 7.6 4.2 5.8 1 8 4.2 0.4 0 0.4 0.4 357 5 0 305 0 0 0 0 2 0 2.5 2 09/24/2004 21:10:00 5.1 0.6 6.8 3.8 5.3 0.6 6.8 3.8 0.4 0 0.4 0.4 338 13 323 305 0 0 0 0 2 0 2.5 2 09/24/2004 21:20:00 5.6 0.8 7.6 3.8 5.8 0.9 8.4 3.8 0.4 0 0.4 0.4 341 12 334 305 0 0 0 0 2 0 2.5 2 09/24/2004 21:30:00 5.4 0.6 6.5 3.4 5.5 0.6 6.8 3.8 0.4 0 0.4 0.4 329 9 341 305 0 0 0 0 2 0 2.5 2 09/24/2004 21:40:00 4.7 0.9 7.6 2.6 4.9 0.8 6.8 3 0.4 0 0.4 0.4 342 15 336 305 0 0 0 0 2 0 2.5 2 09/24/2004 21:50:00 5.3 0.9 6.8 3 5.5 0.9 7.2 3 0.4 0 0.4 0.4 348 9 341 305 0 0 0 0 2 0 2.5 2 09/24/2004 22:00:00 4.6 0.5 6.1 3.8 4.8 0.5 6.1 3.4 0.4 0 0.4 0.4 355 7 359 305 0 0 0 0 2 0 2.5 2 09/24/2004 22:10:00 4.7 0.7 6.5 3 4.9 0.8 6.8 3 0.4 0 0.4 0.4 344 9 344 305 0 0 0 0 2 0 2.5 2 09/24/2004 22:20:00 4.9 0.4 6.5 3.8 5.1 0.5 6.8 3.4 0.4 0 0.4 0.4 346 8 348 305 0 0 0 0 2 0 2.5 2 09/24/2004 22:30:00 4.7 0.6 6.5 3.4 4.9 0.6 6.8 3.8 0.4 0 0.4 0.4 355 7 349 305 0 0 0 0 2 0 2.5 2 09/24/2004 22:40:00 4.7 0.7 6.1 3 4.8 0.7 6.5 3.4 0.4 0 0.4 0.4 355 7 351 305 0 0 0 0 2 0 2.5 2 09/24/2004 22:50:00 4.7 0.6 6.5 3.4 4.8 0.6 6.5 3.4 0.4 0 0.4 0.4 358 10 356 305 0 0 0 0 2 0 2.5 2 09/24/2004 23:00:00 4.2 0.7 6.1 2.6 4.4 0.7 6.1 2.6 0.4 0 0.4 0.4 1 4 2 305 0 0 0 0 2 0 2.5 2 09/24/2004 23:10:00 3.8 0.8 6.5 2.3 4 0.9 6.5 2.3 0.4 0 0.4 0.4 354 9 352 305 0 0 0 0 2 0 2.5 2 09/24/2004 23:20:00 4.8 0.8 6.5 3 4.9 0.8 6.5 3.4 0.4 0 0.4 0.4 357 10 0 305 0 0 0 0 2 0 2.5 2 09/24/2004 23:30:00 4 0.6 5.3 2.6 4.2 0.6 5.7 3 0.4 0 0.4 0.4 341 6 350 305 0 0 0 0 1.9 0.1 2.5 1.7 09/24/2004 23:40:00 2.9 0.6 4.2 1.9 3.1 0.6 4.6 1.9 0.4 0 0.4 0.4 330 8 344 305 0 0 0 0 1.9 0.1 2.2 1.7 09/24/2004 23:50:00 3.4 0.7 5.3 2.3 3.6 0.6 4.9 2.3 0.4 0 0.4 0.4 355 18 7 305 0 0 0 0 1.8 0.1 2.2 1.5 09/25/2004 00:00:00 3.3 0.7 5.3 1.9 3.5 0.8 5.7 2.3 0.4 0 0.4 0.4 351 11 339 305 0 0 0 0 1.7 0.1 2.2 1.5 09/25/2004 00:10:00 3.1 1 5.3 1.5 3.4 1 5.3 1.9 0.4 0 0.4 0.4 346 11 353 305 0 0 0 0 1.6 0.1 2.2 1.5 09/25/2004 00:20:00 2.7 0.5 4.2 1.5 2.9 0.5 4.6 1.9 0.4 0 0.4 0.4 353 6 355 305 0 0 0 0 1.7 0.1 2.2 1.5 09/25/2004 00:30:00 2.4 0.6 3.8 1.1 2.7 0.5 3.8 1.5 0.4 0 0.4 0.4 350 10 347 305 0 0 0 0 1.6 0 2.2 1.5 09/25/2004 00:40:00 2.9 0.8 4.6 1.5 3.2 0.8 4.9 1.9 0.4 0 0.4 0.4 341 6 341 305 0 0 0 0 1.6 0 2.2 1.5 09/25/2004 00:50:00 2.9 0.7 4.6 1.5 3.1 0.7 4.9 1.5 0.4 0 0.4 0.4 338 12 330 305 0 0 0 0 1.6 0 2.2 1.5 09/25/2004 01:00:00 4 0.8 5.3 1.1 4.2 0.8 5.7 2.3 0.4 0 0.4 0.4 350 7 344 305 0 0 0 0 1.6 0 2 1.5 09/25/2004 01:10:00 2.9 0.8 4.2 1.1 3.2 0.7 4.6 1.5 0.4 0 0.4 0.4 338 7 353 305 0 0 0 0 1.6 0 2.2 1.5 09/25/2004 01:20:00 3.2 0.8 5.7 1.5 3.4 0.7 5.3 1.9 0.4 0 0.4 0.4 339 13 323 305 0 0 0 0 1.5 0 2 1.3 09/25/2004 01:30:00 2 0.5 3.4 1.1 2.2 0.5 3.8 1.5 0.4 0 0.4 0.4 333 18 324 305 0 0 0 0 1.5 0 2 1.3 09/25/2004 01:40:00 2.7 1.1 4.6 0.4 2.8 1.1 4.9 0.4 0.4 0 0.4 0.4 344 19 340 305 0 0 0 0 1.4 0 2 1.3 09/25/2004 01:50:00 3.1 0.4 4.6 1.9 3.3 0.5 4.6 2.3 0.4 0 0.4 0.4 325 10 327 305 0 0 0 0 1.3 0 2 1 09/25/2004 02:00:00 1.6 0.6 3 0.4 2 0.5 3.4 1.1 0.4 0 0.4 0.4 331 13 314 305 0 0 0 0 1.6 0 2 1.5 09/25/2004 02:10:00 1.6 0.5 3 0.7 1.9 0.5 3 0.7 0.4 0 0.4 0.4 342 19 342 305 0 0 0 0 1.6 0 2 1.3 09/25/2004 02:20:00 1.6 0.6 3 0.4 1.9 0.5 3.4 0.7 0.4 0 0.4 0.4 317 7 310 305 0 0 0 0 1.2 0.1 1.5 1 09/25/2004 02:30:00 0.6 0.3 2.3 0.4 1 0.5 2.6 0.4 0.4 0 0.4 0.4 333 15 313 305 0 0 0 0 1.4 0 2 1.3 09/25/2004 02:40:00 1.5 0.5 2.6 0.4 1.8 0.4 2.6 0.7 0.4 0 0.4 0.4 339 19 319 305 0 0 0 0 1.1 0 1.5 1 09/25/2004 02:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 4 0 5 305 0 0 0 0 0.6 0.2 1.5 0.3 09/25/2004 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 0 305 305 0 0 0 0 0.2 0.1 0.6 0.1 09/25/2004 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 0 305 305 0 0 0 0 -0.1 0.1 0.3 -0.4 09/25/2004 03:20:00 0.4 0 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 335 38 279 305 0 0 0 0 -0.4 0.1 0.1 -0.6 09/25/2004 03:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 284 19 288 305 0 0 0 0 -0.6 0.2 0.1 -1.1 09/25/2004 03:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 279 4 293 305 0 0 0 0 -0.7 0.3 0.3 -1.1 09/25/2004 03:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 288 10 292 305 0 0 0 0 0.3 0.1 0.8 0.1 09/25/2004 04:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 298 1 305 305 0 0 0 0 0.6 0.1 1.3 0.6 09/25/2004 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 0 305 305 0 0 0 0 0.2 0.2 0.8 -0.4 09/25/2004 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 0 305 305 0 0 0 0 -0.1 0.1 0.3 -0.4 09/25/2004 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 0 305 305 0 0 0 0 0 0 0.6 -0.1 09/25/2004 04:40:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 283 15 305 305 0 0 0 0 0.2 0.1 0.6 0.1 09/25/2004 04:50:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 258 20 203 305 0 0 0 0 0.1 0.1 0.6 0.1 09/25/2004 05:00:00 0.6 0.3 1.1 0.4 1.5 0.5 2.6 0.4 0.4 0 0.4 0.4 187 13 204 305 0 0 0 0 0 0.1 0.6 -0.1 09/25/2004 05:10:00 1.4 0.3 1.9 0.7 2.2 0.3 2.6 1.9 0.4 0 0.4 0.4 175 2 171 305 0 0 0 0 -0.1 0.2 0.6 -0.6 09/25/2004 05:20:00 1.2 0.4 2.3 0.4 2.3 0.2 2.6 1.9 0.4 0 0.4 0.4 173 4 176 305 0 0 0 0 -0.3 0.2 0.3 -0.6 09/25/2004 05:30:00 1.6 0.4 3 0.7 2.7 0.2 3.4 2.3 0.4 0 0.4 0.4 166 5 179 305 0 0 0 0 -0.1 0.2 0.6 -0.4 09/25/2004 05:40:00 2.1 0.6 3.4 1.1 3.1 0.2 3.4 2.6 0.4 0 0.4 0.4 163 3 160 305 0 0 0 0 0.2 0.1 0.6 0.1 09/25/2004 05:50:00 2.9 0.3 3.4 1.9 3.3 0.2 3.8 2.6 0.4 0 0.4 0.4 158 3 156 305 0 0 0 0 0.2 0.1 0.6 0.1 09/25/2004 06:00:00 2 0.4 3.4 1.1 3.7 0.2 4.2 3 0.4 0 0.4 0.4 167 2 163 305 0 0 0 0 0.3 0.1 1 0.1 09/25/2004 06:10:00 2.7 0.7 4.2 1.5 3.4 0.3 4.2 2.3 0.4 0 0.4 0.4 179 5 192 305 0 0 0 0 0.6 0.1 1.3 0.6 09/25/2004 06:20:00 2 0.4 3 1.1 4 0.3 4.6 3.4 0.4 0 0.4 0.4 172 2 176 305 0 0 0 0 0.8 0.1 1.3 0.6 09/25/2004 06:30:00 3.1 0.8 4.6 1.9 4.8 0.3 5.3 3.8 0.4 0 0.4 0.4 166 4 163 305 0 0 0 0 0.8 0.1 1.3 0.6 09/25/2004 06:40:00 3.4 0.4 4.2 2.3 4.5 0.2 4.9 3.8 0.4 0 0.4 0.4 163 2 161 305 0 0 0 0 0.9 0.1 1.3 0.8 09/25/2004 06:50:00 3.9 0.5 4.9 3 4.6 0.3 4.9 3.8 0.4 0 0.4 0.4 160 2 159 305 0 0 0 0 0.8 0.1 1.3 0.6 09/25/2004 07:00:00 4.6 0.2 5.3 3.8 4.4 0.4 4.9 3.4 0.4 0 0.4 0.4 156 2 156 305 0 0 0 0 0.8 0.1 1.3 0.6 09/25/2004 07:10:00 4.8 0.2 5.3 4.2 5.1 0.2 5.7 4.6 0.4 0 0.4 0.4 159 1 157 305 0 0 0 0 1 0.1 1.5 0.8 09/25/2004 07:20:00 4.9 0.4 5.7 3 5.3 0.2 5.7 4.6 0.4 0 0.4 0.4 158 2 156 305 0 0 0 0 1 0 1.5 1 09/25/2004 07:30:00 4.3 0.8 5.7 2.3 5.2 0.2 5.7 4.6 0.4 0 0.4 0.4 161 4 158 305 0 0 0 0 1.1 0 1.5 1 09/25/2004 07:40:00 4.9 0.8 6.5 2.6 5.3 0.4 6.1 4.2 0.4 0 0.4 0.4 159 5 151 305 0 0 0 0 1 0 1.5 0.8 09/25/2004 07:50:00 6.3 0.6 7.6 4.6 6.1 0.5 7.2 4.6 0.4 0 0.4 0.4 156 3 155 305 0 0 0 0 0.9 0 1.5 0.8 09/25/2004 08:00:00 6.5 0.5 7.6 4.9 6.3 0.4 7.2 4.9 0.4 0 0.4 0.4 155 3 154 305 0 0 0 0 1.1 0 1.5 1 09/25/2004 08:10:00 7.4 0.7 8.8 5.7 7 0.6 8.4 5.7 0.4 0 0.4 0.4 153 3 155 305 0 0 0 0 1 0 1.5 0.8 09/25/2004 08:20:00 7.8 0.7 8.8 5.3 7.4 0.6 8.4 5.3 0.4 0 0.4 0.4 153 3 153 305 0 0 0 0 1 0 1.5 1 09/25/2004 08:30:00 7.2 0.5 8.4 5.3 7.1 0.4 8 5.7 0.4 0 0.4 0.4 158 3 156 305 0 0 0 0 1 0 1.5 1 09/25/2004 08:40:00 7.7 0.5 8.8 6.5 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 154 4 158 305 0 0 0 0 1.2 0.1 1.7 1 09/25/2004 08:50:00 7.9 0.6 9.1 6.1 7.5 0.5 8.8 5.7 0.4 0 0.4 0.4 153 4 152 305 0 0 0 0 1.2 0.1 1.5 1 09/25/2004 09:00:00 7.4 0.6 8.8 5.7 7.1 0.6 8.8 5.7 0.4 0 0.4 0.4 149 5 143 305 0 0 0 0 1.1 0.1 1.5 1 09/25/2004 09:10:00 7 0.7 9.5 5.3 6.9 0.6 8.8 4.9 0.4 0 0.4 0.4 151 6 151 305 0 0 0 0 1.2 0.1 1.5 1 09/25/2004 09:20:00 7.5 1 9.9 4.9 7.4 0.9 10.3 5.3 0.4 0 0.4 0.4 149 7 143 305 0 0 0 0 1.2 0.1 1.7 1 09/25/2004 09:30:00 8.6 0.8 10.7 6.5 8.2 0.8 10.3 6.1 0.4 0 0.4 0.4 149 6 153 305 0 0 0 0 1.4 0.1 2 1.3 09/25/2004 09:40:00 8.5 0.9 11.1 5.7 8.3 0.8 10.7 6.5 0.4 0 0.4 0.4 146 7 146 305 0 0 0 0 1.6 0.1 2.2 1.5 09/25/2004 09:50:00 8.9 0.9 11.8 6.8 8.6 0.9 11.1 6.5 0.4 0 0.4 0.4 148 6 150 305 0 0 0 0 1.7 0.2 2.2 1.5 09/25/2004 10:00:00 9.3 0.7 11.1 7.2 9 0.7 10.7 6.8 0.4 0 0.4 0.4 150 5 155 305 0 0 0 0 1.9 0.1 2.5 1.7 09/25/2004 10:10:00 10.4 0.8 12.2 8 9.8 0.7 11.8 7.2 0.4 0 0.4 0.4 154 4 155 305 0 0 0 0 2 0 2.5 2 09/25/2004 10:20:00 9.8 1.7 12.6 5.3 10.2 1.1 12.6 6.1 0.4 0 0.4 0.4 160 9 156 305 0 0 0 0 2 0.1 2.7 2 09/25/2004 10:30:00 8 1.3 11.1 4.9 9.3 0.9 11.8 6.8 0.4 0 0.4 0.4 179 5 184 305 0 0 0 0 2.2 0.3 2.9 1.5 09/25/2004 10:40:00 7.7 1.3 10.3 4.6 8.4 1 10.7 6.5 0.4 0 0.4 0.4 180 5 186 305 0 0 0 0 0.8 0.4 2 0.3 09/25/2004 10:50:00 5.4 0.8 8 3.8 7 0.7 8.4 4.9 0.4 0 0.4 0.4 170 6 183 305 0 0 0 0 0.3 0 0.6 0.1 09/25/2004 11:00:00 6.4 1.1 8.4 4.2 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 161 5 156 305 0 0 0 0 0.2 0 0.6 0.1 09/25/2004 11:10:00 7.4 1 9.9 4.2 7.3 0.8 9.5 5.7 0.4 0 0.4 0.4 154 6 160 305 0 0 0 0 0.5 0.2 1.3 0.3 09/25/2004 11:20:00 4.4 1 6.8 2.6 5.4 0.8 7.2 3.8 0.4 0 0.4 0.4 166 9 153 305 0 0 0 0 1.2 0.2 1.7 0.8 09/25/2004 11:30:00 4.4 0.7 6.1 2.6 5 0.6 6.8 3.4 0.4 0 0.4 0.4 183 8 177 305 0 0 0 0 1.9 0.3 2.7 1.3 09/25/2004 11:40:00 4.4 0.4 5.7 3.4 4.6 0.4 5.7 3.8 0.4 0 0.4 0.4 196 6 184 305 0 0 0 0 2.2 0.1 2.7 2.2 09/25/2004 11:50:00 3.6 0.6 5.3 1.9 3.8 0.6 5.3 2.6 0.4 0 0.4 0.4 200 11 202 305 0 0 0 0 2.4 0.1 2.9 2.2 09/25/2004 12:00:00 4.7 0.8 6.5 2.6 4.4 0.7 6.8 3 0.4 0 0.4 0.4 229 13 219 305 0 0 0 0 2.6 0.1 3.2 2.5 09/25/2004 12:10:00 5 0.6 7.2 3.8 4.7 0.5 6.8 3 0.4 0 0.4 0.4 245 10 282 305 0 0 0 0 2.8 0.1 3.4 2.7 09/25/2004 12:20:00 6.8 1.3 9.1 3 6.4 1.3 8.8 3 0.4 0 0.4 0.4 294 11 305 305 0 0 0 0 2.9 0.1 3.4 2.7 09/25/2004 12:30:00 5.8 0.6 7.2 4.2 5.5 0.6 6.8 4.2 0.4 0 0.4 0.4 293 6 295 305 0 0 0 0 2.8 0.1 3.4 2.7 09/25/2004 12:40:00 5.4 0.6 6.5 3.8 4.9 0.6 6.1 3.4 0.4 0 0.4 0.4 283 5 290 305 0 0 0 0 3 0.1 3.7 2.7 09/25/2004 12:50:00 7.4 1.1 9.5 4.2 6.8 1.1 9.5 3.4 0.4 0 0.4 0.4 288 5 284 305 0 0 0 0 3.3 0 3.7 3.2 09/25/2004 13:00:00 10.4 1.3 13 6.5 9.6 1.3 12.2 6.1 0.4 0 0.4 0.4 289 7 300 305 0 0 0 0 2.6 0.4 3.4 2.2 09/25/2004 13:10:00 6.9 1.2 9.5 4.6 6.6 1.2 9.5 4.6 0.4 0 0.4 0.4 298 5 303 305 0 0 0 0 2.3 0.1 2.9 2.2 09/25/2004 13:20:00 6.9 0.8 8.8 4.6 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 292 6 275 305 0 0 0 0 2.8 0.2 3.7 2.5 09/25/2004 13:30:00 8.7 1.1 10.7 4.9 8.2 1.2 10.7 4.9 0.4 0 0.4 0.4 291 6 294 305 0 0 0 0 3.4 0.1 3.7 3.2 09/25/2004 13:40:00 8.8 1 11.5 6.5 8.3 1 10.7 5.7 0.4 0 0.4 0.4 293 6 294 305 0 0 0 0 3.7 0.2 4.4 3.2 09/25/2004 13:50:00 8.8 1 11.5 6.5 8.4 1 10.7 5.3 0.4 0 0.4 0.4 293 9 303 305 0 0 0 0 4.2 0.1 4.7 3.9 09/25/2004 14:00:00 10.1 1.3 13 6.5 9.5 1.5 12.6 6.5 0.4 0 0.4 0.4 293 9 294 305 0 0 0 0 4.4 0 4.9 4.2 09/25/2004 14:10:00 10.2 1.1 13 7.2 9.7 1.2 13 6.1 0.4 0 0.4 0.4 292 8 290 305 0 0 0 0 4.2 0.1 4.7 4.2 09/25/2004 14:20:00 9.9 1.1 11.8 6.1 9.4 1.1 11.8 6.1 0.4 0 0.4 0.4 296 7 294 305 0 0 0 0 4.2 0.1 4.4 3.9 09/25/2004 14:30:00 11 1 13.3 8 10.6 1.2 13.3 7.2 0.4 0 0.4 0.4 297 8 294 305 0 0 0 0 4 0.2 4.7 3.7 09/25/2004 14:40:00 10.6 1.2 13.3 7.2 10.2 1.3 13.3 7.2 0.4 0 0.4 0.4 296 7 290 305 0 0 0 0 3.9 0.1 4.4 3.7 09/25/2004 14:50:00 9.3 0.9 12.2 7.2 9.1 0.9 12.2 6.8 0.4 0 0.4 0.4 302 11 299 305 0 0 0 0 4 0.1 4.4 3.7 09/25/2004 15:00:00 9.7 0.8 11.5 7.6 9.4 0.9 11.8 7.2 0.4 0 0.4 0.4 303 15 292 305 0 0 0 0 3.6 0 3.9 3.4 09/25/2004 15:10:00 9.1 0.8 10.7 7.2 8.9 0.9 11.1 6.8 0.4 0 0.4 0.4 313 8 303 305 0 0 0 0 3.2 0.2 3.7 2.7 09/25/2004 15:20:00 10 1 12.2 6.5 9.9 1.2 12.6 6.1 0.4 0 0.4 0.4 313 6 305 305 0 0 0 0 2.9 0.1 3.4 2.7 09/25/2004 15:30:00 11.3 0.8 13.3 9.1 11.2 0.9 13 9.1 0.4 0 0.4 0.4 314 6 319 305 0 0 0 0 2.7 0 3.2 2.5 09/25/2004 15:40:00 10.3 0.9 12.2 7.6 10.1 1 12.2 6.8 0.4 0 0.4 0.4 316 8 307 305 0 0 0 0 2.7 0 3.2 2.5 09/25/2004 15:50:00 10.3 0.8 12.6 8 10.4 0.9 12.6 8 0.4 0 0.4 0.4 322 6 322 305 0 0 0 0 2.2 0.1 2.7 2 09/25/2004 16:00:00 10.2 0.8 12.6 8 10.3 0.9 13 7.6 0.4 0 0.4 0.4 327 6 323 305 0 0 0 0 2.3 0 2.7 2.2 09/25/2004 16:10:00 10.6 0.7 12.2 8 10.7 0.8 13 8.4 0.4 0 0.4 0.4 328 5 326 305 0 0 0 0 2.3 0.1 2.9 2.2 09/25/2004 16:20:00 10.7 0.9 12.6 8 10.9 1 12.6 8 0.4 0 0.4 0.4 330 5 331 305 0 0 0 0 2.3 0.1 2.7 2.2 09/25/2004 16:30:00 9.9 1 11.5 7.2 10.1 1 12.2 7.6 0.4 0 0.4 0.4 331 6 324 305 0 0 0 0 2.4 0.1 2.9 2.2 09/25/2004 16:40:00 9.7 0.6 11.1 7.6 9.8 0.7 11.5 8 0.4 0 0.4 0.4 335 5 337 305 0 0 0 0 2.2 0.1 2.7 1.7 09/25/2004 16:50:00 9.7 0.7 12.2 7.6 9.7 0.8 12.6 7.6 0.4 0 0.4 0.4 327 6 319 305 0 0 0 0 2.2 0.1 2.7 2 09/25/2004 17:00:00 9.5 0.7 11.5 7.2 9.7 0.7 11.8 7.6 0.4 0 0.4 0.4 330 6 325 305 0 0 0 0 2 0.1 2.5 1.7 09/25/2004 17:10:00 9.7 0.9 12.2 7.2 9.8 1 12.2 7.2 0.4 0 0.4 0.4 331 6 330 305 0 0 0 0 1.7 0.1 2.2 1.3 09/25/2004 17:20:00 9.8 0.7 12.2 7.6 10.1 0.9 11.8 7.2 0.4 0 0.4 0.4 335 5 343 305 0 0 0 0 1.6 0 2 1.5 09/25/2004 17:30:00 10.4 0.9 12.2 8 10.5 1 12.6 7.6 0.4 0 0.4 0.4 332 5 330 305 0 0 0 0 1.6 0.1 2.2 1.3 09/25/2004 17:40:00 10.2 0.9 12.2 7.6 10.4 0.9 12.6 7.6 0.4 0 0.4 0.4 336 6 340 305 0 0 0 0 1.3 0.1 1.5 1.3 09/25/2004 17:50:00 10.5 1.2 13.3 8.4 10.7 1.2 13.3 7.2 0.4 0 0.4 0.4 336 5 335 305 0 0 0 0 1.3 0.2 2 1 09/25/2004 18:00:00 10.1 0.8 11.8 8.4 10.2 0.9 12.2 7.6 0.4 0 0.4 0.4 339 6 345 305 0 0 0 0 1.4 0 1.7 1.3 09/25/2004 18:10:00 9.4 1.5 12.2 6.1 9.5 1.5 13 6.1 0.4 0 0.4 0.4 341 6 339 305 0 0 0 0 1 0.2 1.7 0.8 09/25/2004 18:20:00 9.6 1 12.2 7.6 9.8 1.1 13 7.2 0.4 0 0.4 0.4 345 4 343 305 0 0 0 0 1.2 0.1 1.5 1 09/25/2004 18:30:00 10.1 1 12.2 7.6 10.3 1 12.2 8 0.4 0 0.4 0.4 345 5 341 305 0 0 0 0 1 0.2 1.5 0.6 09/25/2004 18:40:00 10.9 0.9 13.3 7.6 11.2 1 13.7 8.4 0.4 0 0.4 0.4 347 5 343 305 0 0 0 0 1.3 0.1 1.7 1 09/25/2004 18:50:00 11.2 0.7 12.6 9.1 11.4 0.8 13 8.8 0.4 0 0.4 0.4 346 5 350 305 0 0 0 0 1.2 0.1 1.5 1 09/25/2004 19:00:00 11.7 0.7 13 9.5 12 0.8 13.7 9.9 0.4 0 0.4 0.4 346 4 345 305 0 0 0 0 1.1 0.1 1.5 1 09/25/2004 19:10:00 11.3 0.8 13.3 9.1 11.5 0.9 13.7 9.1 0.4 0 0.4 0.4 343 5 339 305 0 0 0 0 1 0 1.5 0.8 09/25/2004 19:20:00 11.1 0.7 12.6 8.8 11.4 0.8 13.3 8.8 0.4 0 0.4 0.4 343 4 344 305 0 0 0 0 0.9 0 1.5 0.6 09/25/2004 19:30:00 11.5 0.7 13.3 9.5 11.7 0.9 13.3 9.1 0.4 0 0.4 0.4 344 4 345 305 0 0 0 0 0.6 0 1.3 0.3 09/25/2004 19:40:00 12 0.7 13.7 10.3 12.2 0.9 14.5 9.9 0.4 0 0.4 0.4 347 5 347 305 0 0 0 0 0.8 0.1 1.3 0.6 09/25/2004 19:50:00 11.5 1.2 14.1 8 11.7 1.2 14.1 8 0.4 0 0.4 0.4 348 4 343 305 0 0 0 0 0.9 0.1 1.5 0.8 09/25/2004 20:00:00 11.9 0.7 13.7 9.1 12.1 0.7 13.7 9.9 0.4 0 0.4 0.4 347 5 345 305 0 0 0 0 0.9 0 1.3 0.6 09/25/2004 20:10:00 11.4 0.8 13.3 9.1 11.6 0.9 13.7 8.8 0.4 0 0.4 0.4 347 6 348 305 0 0 0 0 0.7 0.1 1.3 0.6 09/25/2004 20:20:00 11.3 0.8 13.3 9.5 11.6 0.9 13.7 9.5 0.4 0 0.4 0.4 348 5 345 305 0 0 0 0 0.6 0.1 1 0.6 09/25/2004 20:30:00 10.7 0.8 12.6 8 11 0.8 13 8 0.4 0 0.4 0.4 347 5 347 305 0 0 0 0 0.6 0.1 1.3 0.6 09/25/2004 20:40:00 10.5 0.8 12.2 8.4 10.7 0.9 12.6 8.8 0.4 0 0.4 0.4 347 4 344 305 0 0 0 0 0.6 0.1 1.3 0.6 09/25/2004 20:50:00 10.7 0.6 12.2 9.5 10.8 0.7 12.6 8.8 0.4 0 0.4 0.4 349 5 344 305 0 0 0 0 0.6 0.1 1.3 0.6 09/25/2004 21:00:00 10.2 0.6 11.5 8.8 10.4 0.7 12.2 8.4 0.4 0 0.4 0.4 350 5 355 305 0 0 0 0 0.6 0.1 1.3 0.6 09/25/2004 21:10:00 10.4 0.8 12.2 7.6 10.7 0.9 12.6 7.2 0.4 0 0.4 0.4 349 5 352 305 0 0 0 0 0.7 0.1 1.3 0.6 09/25/2004 21:20:00 10.5 0.7 11.8 8.8 10.7 0.7 12.6 8.4 0.4 0 0.4 0.4 349 5 352 305 0 0 0 0 0.7 0.1 1.3 0.6 09/25/2004 21:30:00 11.3 1 13.3 8.4 11.5 1 14.1 8.4 0.4 0 0.4 0.4 353 4 352 305 0 0 0 0 0.7 0.1 1.3 0.6 09/25/2004 21:40:00 11.6 0.7 13.3 9.5 11.8 0.8 13.7 9.1 0.4 0 0.4 0.4 355 5 355 305 0 0 0 0 0.6 0.1 1 0.6 09/25/2004 21:50:00 10 0.8 11.8 8 10.2 0.8 12.2 7.6 0.4 0 0.4 0.4 358 5 357 305 0 0 0 0 0.6 0.1 1 0.6 09/25/2004 22:00:00 10.5 0.8 12.2 8.4 10.7 0.9 13 8.8 0.4 0 0.4 0.4 350 5 347 305 0 0 0 0 0.5 0 1 0.6 09/25/2004 22:10:00 10.1 0.7 11.8 8.4 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 352 6 357 305 0 0 0 0 0.6 0.1 1.3 0.6 09/25/2004 22:20:00 10 0.7 11.8 8 10.2 0.8 12.2 8.4 0.4 0 0.4 0.4 352 6 355 305 0 0 0 0 0.6 0.1 1.3 0.6 09/25/2004 22:30:00 8.8 0.9 10.7 6.8 9 1 11.1 6.8 0.4 0 0.4 0.4 355 7 347 305 0 0 0 0 0.6 0.1 1 0.6 09/25/2004 22:40:00 9.3 0.8 11.1 7.6 9.6 0.8 11.8 7.6 0.4 0 0.4 0.4 351 5 346 305 0 0 0 0 0.5 0 1 0.3 09/25/2004 22:50:00 9.5 1.3 11.8 6.1 9.7 1.4 12.6 6.8 0.4 0 0.4 0.4 357 6 355 305 0 0 0 0 0.1 0.4 1 -0.6 09/25/2004 23:00:00 9.8 1.3 13 6.1 9.9 1.4 13 5.7 0.4 0 0.4 0.4 3 6 6 305 0 0 0 0 0.1 0.2 0.6 -0.4 09/25/2004 23:10:00 9.4 1.1 12.2 6.8 9.4 1.1 12.2 7.2 0.4 0 0.4 0.4 4 7 9 305 0 0 0 0 0.2 0.1 0.8 0.1 09/25/2004 23:20:00 9.9 1 11.8 7.2 10.1 1.1 12.2 7.6 0.4 0 0.4 0.4 3 5 359 305 0 0 0 0 -0.4 0.2 0.6 -0.6 09/25/2004 23:30:00 9.8 1.7 13.7 6.8 10 1.7 14.1 7.2 0.4 0 0.4 0.4 358 6 1 305 0 0 0 0 0 0.3 0.8 -0.6 09/25/2004 23:40:00 10.4 1.3 13.3 7.6 10.6 1.3 13.7 8 0.4 0 0.4 0.4 359 5 5 305 0 0 0 0 -0.3 0.3 0.6 -0.6 09/25/2004 23:50:00 9.4 0.7 11.1 7.2 9.6 0.7 11.5 7.6 0.4 0 0.4 0.4 1 5 2 305 0 0 0 0 -0.5 0.1 0.1 -0.6 09/26/2004 00:00:00 9.1 0.7 11.1 7.2 9.3 0.7 11.1 7.2 0.4 0 0.4 0.4 4 5 1 305 0 0 0 0 -0.5 0.1 0.1 -0.8 09/26/2004 00:10:00 9.9 0.8 11.8 8 10.1 0.8 11.8 7.2 0.4 0 0.4 0.4 4 5 4 305 0 0 0 0 0 0 0.6 -0.4 09/26/2004 00:20:00 9.5 0.8 11.5 6.8 9.8 0.8 11.8 7.2 0.4 0 0.4 0.4 348 9 348 305 0 0 0 0 0.4 0 1 0.3 09/26/2004 00:30:00 10.1 1 13 7.6 10.3 1 13.3 7.6 0.4 0 0.4 0.4 339 6 328 305 0 0 0 0 0.3 0 0.6 0.1 09/26/2004 00:40:00 9.5 0.7 11.5 7.2 9.8 0.8 11.8 7.6 0.4 0 0.4 0.4 341 4 341 305 0 0 0 0 0.2 0 0.6 0.1 09/26/2004 00:50:00 9.1 0.8 11.1 6.8 9.3 0.8 11.1 6.8 0.4 0 0.4 0.4 341 5 347 305 0 0 0 0 0.2 0.1 0.6 0.1 09/26/2004 01:00:00 8.4 0.7 9.9 6.5 8.6 0.8 10.7 6.8 0.4 0 0.4 0.4 349 6 353 305 0 0 0 0 0.1 0 0.6 0.1 09/26/2004 01:10:00 7.7 0.7 9.9 6.1 7.9 0.8 9.9 5.7 0.4 0 0.4 0.4 348 7 346 305 0 0 0 0 0.1 0.1 0.6 0.1 09/26/2004 01:20:00 7.7 0.9 9.9 5.7 7.9 0.9 10.7 6.1 0.4 0 0.4 0.4 351 5 348 305 0 0 0 0 0 0.1 0.6 0.1 09/26/2004 01:30:00 8.1 0.6 9.5 6.8 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 351 7 344 305 0 0 0 0 0.1 0.1 0.6 0.1 09/26/2004 01:40:00 7.9 0.6 9.5 6.1 8.2 0.7 9.9 6.1 0.4 0 0.4 0.4 349 7 0 305 0 0 0 0 0 0 0.6 -0.1 09/26/2004 01:50:00 7.3 0.8 8.8 4.9 7.5 0.9 9.1 4.9 0.4 0 0.4 0.4 353 7 351 305 0 0 0 0 -0.1 0 0.6 -0.4 09/26/2004 02:00:00 7.3 0.7 9.1 5.7 7.5 0.7 9.5 5.7 0.4 0 0.4 0.4 352 6 348 305 0 0 0 0 -0.1 0 0.3 -0.4 09/26/2004 02:10:00 7.2 0.8 9.1 5.3 7.4 0.9 9.5 5.3 0.4 0 0.4 0.4 0 6 359 305 0 0 0 0 -0.1 0 0.3 -0.4 09/26/2004 02:20:00 7.3 0.6 8.8 5.7 7.5 0.7 9.1 6.1 0.4 0 0.4 0.4 358 6 357 305 0 0 0 0 -0.2 0 0.3 -0.4 09/26/2004 02:30:00 6.8 0.7 8.4 5.3 6.9 0.7 9.1 5.3 0.4 0 0.4 0.4 353 5 350 305 0 0 0 0 -0.3 0.1 0.3 -0.4 09/26/2004 02:40:00 7.1 0.8 9.5 4.9 7.3 0.9 9.5 5.3 0.4 0 0.4 0.4 357 9 355 305 0 0 0 0 -0.3 0.1 0.1 -0.4 09/26/2004 02:50:00 6.9 1 11.5 3.8 7.1 1 10.3 3.8 0.4 0 0.4 0.4 354 9 13 305 0 0 0 0 -0.3 0.1 0.1 -0.4 09/26/2004 03:00:00 6.5 0.9 8.8 4.6 6.7 0.9 8.8 4.9 0.4 0 0.4 0.4 355 10 352 305 0 0 0 0 -0.4 0.1 0.1 -0.6 09/26/2004 03:10:00 6.2 0.7 8.4 4.6 6.4 0.7 8.8 4.6 0.4 0 0.4 0.4 349 8 358 305 0 0 0 0 -0.4 0.1 0.1 -0.6 09/26/2004 03:20:00 6 0.6 7.6 4.6 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 348 6 338 305 0 0 0 0 -0.5 0 0.1 -0.6 09/26/2004 03:30:00 5.8 0.7 7.6 4.2 6 0.8 8 4.2 0.4 0 0.4 0.4 352 10 358 305 0 0 0 0 -0.5 0 0.1 -0.6 09/26/2004 03:40:00 5.2 0.8 7.2 3.4 5.4 0.8 7.2 3.4 0.4 0 0.4 0.4 350 8 355 305 0 0 0 0 -0.6 0 0.1 -0.6 09/26/2004 03:50:00 5.4 0.9 7.2 3.8 5.6 0.8 7.2 3.8 0.4 0 0.4 0.4 350 8 340 305 0 0 0 0 -0.6 0 -0.1 -0.6 09/26/2004 04:00:00 5.3 0.7 7.2 3.4 5.5 0.7 8 3.8 0.4 0 0.4 0.4 348 8 356 305 0 0 0 0 -0.7 0 -0.6 -0.8 09/26/2004 04:10:00 5.6 0.7 7.2 3.8 5.8 0.8 8 4.2 0.4 0 0.4 0.4 358 10 358 305 0 0 0 0 -0.7 0 -0.4 -0.8 09/26/2004 04:20:00 4.7 0.6 6.1 3 4.9 0.5 6.1 3.4 0.4 0 0.4 0.4 8 9 18 305 0 0 0 0 -0.7 0 -0.1 -0.8 09/26/2004 04:30:00 4.7 0.8 6.8 3 4.8 0.8 6.8 3.4 0.4 0 0.4 0.4 8 8 6 305 0 0 0 0 -0.6 0 -0.1 -0.6 09/26/2004 04:40:00 4.4 0.5 5.3 3 4.6 0.5 5.7 3.8 0.4 0 0.4 0.4 353 13 357 305 0 0 0 0 -0.6 0 0.1 -0.6 09/26/2004 04:50:00 3.3 0.6 4.9 1.9 3.5 0.6 5.3 1.9 0.4 0 0.4 0.4 345 12 344 305 0 0 0 0 -0.7 0 -0.1 -0.8 09/26/2004 05:00:00 2.3 0.8 3.8 0.4 2.6 0.7 4.2 1.1 0.4 0 0.4 0.4 359 9 347 305 0 0 0 0 -0.7 0.1 -0.1 -0.8 09/26/2004 05:10:00 3.4 0.5 4.9 2.3 3.6 0.5 5.3 2.6 0.4 0 0.4 0.4 352 9 3 305 0 0 0 0 -0.6 0 -0.1 -0.6 09/26/2004 05:20:00 3.4 0.7 5.3 1.9 3.6 0.7 5.3 2.3 0.4 0 0.4 0.4 348 10 352 305 0 0 0 0 -0.6 0 0.1 -0.8 09/26/2004 05:30:00 3.1 0.7 4.6 1.5 3.3 0.7 4.9 1.5 0.4 0 0.4 0.4 345 8 351 305 0 0 0 0 -0.7 0 -0.1 -0.8 09/26/2004 05:40:00 2.4 0.5 3.4 0.7 2.6 0.4 3.4 1.5 0.4 0 0.4 0.4 324 18 307 305 0 0 0 0 -0.5 0 0.1 -0.6 09/26/2004 05:50:00 2 0.4 3 1.1 2.2 0.4 3 1.5 0.4 0 0.4 0.4 319 15 331 305 0 0 0 0 -0.7 0.1 0.1 -1.1 09/26/2004 06:00:00 1.6 0.6 3 0.4 1.9 0.5 3 0.7 0.4 0 0.4 0.4 318 18 310 305 0 0 0 0 -0.7 0 -0.1 -0.8 09/26/2004 06:10:00 2.2 0.6 3.8 0.7 2.1 0.7 3.8 0.7 0.4 0 0.4 0.4 286 9 302 305 0 0 0 0 -0.9 0.1 -0.4 -1.1 09/26/2004 06:20:00 2.1 0.5 3.4 0.7 2.1 0.5 3.4 0.7 0.4 0 0.4 0.4 285 11 283 305 0 0 0 0 -0.8 0.1 -0.4 -1.1 09/26/2004 06:30:00 1.9 0.9 3.8 0.4 1.8 0.8 3.4 0.7 0.4 0 0.4 0.4 288 17 302 305 0 0 0 0 -0.8 0.1 -0.4 -1.1 09/26/2004 06:40:00 2.1 0.6 3.4 0.7 1.9 0.6 3 0.4 0.4 0 0.4 0.4 280 13 279 305 0 0 0 0 -1 0.1 -0.6 -1.1 09/26/2004 06:50:00 2.3 0.6 4.2 1.1 2.2 0.5 3.4 1.1 0.4 0 0.4 0.4 291 11 277 305 0 0 0 0 -0.9 0.1 -0.4 -1.1 09/26/2004 07:00:00 1.9 0.6 3.4 0.7 1.9 0.5 3 1.1 0.4 0 0.4 0.4 296 5 296 305 0 0 0 0 -1 0.1 -0.6 -1.1 09/26/2004 07:10:00 1.5 0.4 2.6 0.7 1.4 0.3 2.3 0.7 0.4 0 0.4 0.4 271 10 264 305 0 0 0 0 -0.8 0 -0.4 -1.1 09/26/2004 07:20:00 1.8 0.6 3 0.4 1.6 0.5 3 0.4 0.4 0 0.4 0.4 271 8 261 305 0 0 0 0 -0.7 0 -0.4 -0.8 09/26/2004 07:30:00 1.3 0.7 2.6 0.4 1.2 0.6 2.6 0.4 0.4 0 0.4 0.4 274 12 277 305 0 0 0 0 -0.7 0 -0.1 -0.6 09/26/2004 07:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 267 7 285 305 0 0 0 0 -0.8 0 -0.4 -1.1 09/26/2004 07:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 268 0 305 305 0 0 0 0 -1.1 0.1 -0.4 -1.1 09/26/2004 08:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 264 4 305 305 0 0 0 0 -1.1 0 -0.4 -1.3 09/26/2004 08:10:00 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 235 32 189 305 0 0 0 0 -1 0.1 -0.6 -1.1 09/26/2004 08:20:00 0.7 0.4 1.9 0.4 1.4 0.3 1.9 0.4 0.4 0 0.4 0.4 167 12 159 305 0 0 0 0 -1.1 0 -0.6 -1.3 09/26/2004 08:30:00 0.4 0.2 1.1 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 163 9 171 305 0 0 0 0 -1.1 0 -0.6 -1.3 09/26/2004 08:40:00 0.6 0.3 1.1 0.4 1.2 0.3 1.9 0.4 0.4 0 0.4 0.4 144 5 144 305 0 0 0 0 -1.2 0 -0.8 -1.3 09/26/2004 08:50:00 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 129 2 128 305 0 0 0 0 -1.2 0.1 -0.6 -1.3 09/26/2004 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 128 0 305 305 0 0 0 0 -1.1 0 -0.6 -1.3 09/26/2004 09:10:00 0.5 0.2 1.1 0.4 1 0.4 1.9 0.4 0.4 0 0.4 0.4 133 6 140 305 0 0 0 0 -1.1 0 -0.6 -1.3 09/26/2004 09:20:00 0.6 0.3 1.5 0.4 1.6 0.4 2.3 0.7 0.4 0 0.4 0.4 141 0 140 305 0 0 0 0 -1.1 0 -0.6 -1.3 09/26/2004 09:30:00 1 0.8 3.4 0.4 1.4 0.6 3.4 0.4 0.4 0 0.4 0.4 184 36 218 305 0 0 0 0 -1 0.1 -0.4 -1.1 09/26/2004 09:40:00 3.2 1.1 4.9 0.4 3.1 0.9 4.9 0.7 0.4 0 0.4 0.4 260 29 245 305 0 0 0 0 -0.8 0.1 -0.4 -1.1 09/26/2004 09:50:00 3.1 0.5 4.6 1.5 3.2 0.4 4.2 1.9 0.4 0 0.4 0.4 227 6 228 305 0 0 0 0 -1.5 0.2 -0.6 -2 09/26/2004 10:00:00 2 0.6 3 0.4 2.1 0.5 3 0.7 0.4 0 0.4 0.4 209 7 219 305 0 0 0 0 -2 0 -1.8 -2 09/26/2004 10:10:00 1.5 0.2 1.9 0.7 1.7 0.2 2.3 0.7 0.4 0 0.4 0.4 232 21 199 305 0 0 0 0 -2 0 -1.5 -2 09/26/2004 10:20:00 2.2 0.7 3.4 0.7 2.4 0.8 3.8 1.1 0.4 0 0.4 0.4 208 27 205 305 0 0 0 0 -1.9 0 -1.5 -2 09/26/2004 10:30:00 3 0.4 3.8 1.1 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 183 3 186 305 0 0 0 0 -1.8 0 -1.8 -2 09/26/2004 10:40:00 1.9 0.4 2.6 0.7 2.4 0.4 3.4 1.5 0.4 0 0.4 0.4 178 8 178 305 0 0 0 0 -1.5 0.1 -1.1 -1.8 09/26/2004 10:50:00 1.7 0.5 3 0.7 2.5 0.3 3 1.1 0.4 0 0.4 0.4 164 6 158 305 0 0 0 0 -1.2 0 -1.1 -1.3 09/26/2004 11:00:00 2.8 0.5 3.8 1.5 3 0.4 3.8 1.9 0.4 0 0.4 0.4 153 5 152 305 0 0 0 0 -1 0.1 -0.4 -1.1 09/26/2004 11:10:00 2.9 0.4 3.8 1.9 3 0.4 3.8 2.3 0.4 0 0.4 0.4 148 5 149 305 0 0 0 0 -0.5 0.1 0.1 -0.8 09/26/2004 11:20:00 2.4 0.5 3.4 0.7 2.6 0.4 3.4 1.5 0.4 0 0.4 0.4 150 10 146 305 0 0 0 0 -0.3 0 0.1 -0.4 09/26/2004 11:30:00 1.7 0.6 3.4 0.4 2.2 0.5 3.4 1.1 0.4 0 0.4 0.4 159 11 158 305 0 0 0 0 -0.3 0 0.3 -0.4 09/26/2004 11:40:00 2.6 0.4 3.4 1.5 2.8 0.4 3.8 1.5 0.4 0 0.4 0.4 140 7 140 305 0 0 0 0 -0.3 0 0.3 -0.4 09/26/2004 11:50:00 2.9 0.4 3.8 1.9 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 135 5 130 305 0 0 0 0 -0.3 0.1 0.1 -0.4 09/26/2004 12:00:00 2.1 0.6 3.4 0.4 2.4 0.5 3.4 1.5 0.4 0 0.4 0.4 144 10 133 305 0 0 0 0 -0.3 0 0.3 -0.4 09/26/2004 12:10:00 1.8 0.3 2.6 1.1 2.1 0.3 2.6 1.1 0.4 0 0.4 0.4 137 8 142 305 0 0 0 0 -0.1 0.1 0.3 -0.4 09/26/2004 12:20:00 1.5 0.3 2.3 0.4 1.8 0.3 2.6 0.7 0.4 0 0.4 0.4 137 6 134 305 0 0 0 0 0 0 0.6 -0.1 09/26/2004 12:30:00 1.6 0.5 3 0.7 1.9 0.4 3 1.1 0.4 0 0.4 0.4 142 8 140 305 0 0 0 0 0 0.1 0.6 0.1 09/26/2004 12:40:00 1.7 0.8 3.4 0.4 2.2 0.6 3.4 0.4 0.4 0 0.4 0.4 147 19 133 305 0 0 0 0 0.1 0.1 0.6 0.1 09/26/2004 12:50:00 2.1 0.8 3.8 0.4 2.4 0.6 3.8 0.7 0.4 0 0.4 0.4 140 26 158 305 0 0 0 0 0.4 0 1 0.1 09/26/2004 13:00:00 2.5 0.9 4.9 0.4 2.4 0.8 4.6 0.4 0.4 0 0.4 0.4 93 29 69 305 0 0 0 0 1.3 0.5 2.2 0.3 09/26/2004 13:10:00 3.8 0.5 5.3 2.3 3.8 0.5 5.3 2.6 0.4 0 0.4 0.4 60 10 76 305 0 0 0 0 0.9 0.5 2.2 0.1 09/26/2004 13:20:00 4.1 0.6 5.7 2.3 4 0.6 5.3 2.6 0.4 0 0.4 0.4 61 8 54 305 0 0 0 0 0 0.1 0.6 -0.1 09/26/2004 13:30:00 3.8 0.5 4.9 2.3 3.8 0.4 4.9 2.3 0.4 0 0.4 0.4 65 6 77 305 0 0 0 0 0 0 0.6 -0.4 09/26/2004 13:40:00 3.9 0.6 5.3 2.3 3.8 0.6 5.3 2.3 0.4 0 0.4 0.4 65 8 58 305 0 0 0 0 0 0.1 0.3 -0.4 09/26/2004 13:50:00 4.2 0.5 6.1 3 4.2 0.6 6.5 2.6 0.4 0 0.4 0.4 60 8 53 305 0 0 0 0 -0.1 0 0.6 -0.4 09/26/2004 14:00:00 3.8 0.6 5.3 2.3 3.8 0.6 5.3 1.9 0.4 0 0.4 0.4 70 9 71 305 0 0 0 0 -0.1 0 0.6 -0.4 09/26/2004 14:10:00 4.2 0.5 5.3 3 4.1 0.5 5.3 3 0.4 0 0.4 0.4 66 6 59 305 0 0 0 0 -0.1 0 0.3 -0.4 09/26/2004 14:20:00 3.7 0.7 5.7 2.3 3.6 0.8 5.3 2.3 0.4 0 0.4 0.4 62 9 53 305 0 0 0 0 0 0.2 0.6 -0.4 09/26/2004 14:30:00 3.5 0.5 4.9 2.3 3.4 0.5 4.9 2.3 0.4 0 0.4 0.4 60 9 60 305 0 0 0 0 0 0.1 0.6 0.1 09/26/2004 14:40:00 3.6 0.6 4.9 1.9 3.6 0.6 4.9 2.3 0.4 0 0.4 0.4 63 10 57 305 0 0 0 0 0 0.1 0.6 0.1 09/26/2004 14:50:00 3.2 0.6 4.9 1.9 3.3 0.6 4.6 2.3 0.4 0 0.4 0.4 44 8 44 305 0 0 0 0 -0.2 0.1 0.6 -0.4 09/26/2004 15:00:00 3.4 0.5 4.9 2.3 3.5 0.6 4.9 1.9 0.4 0 0.4 0.4 26 14 32 305 0 0 0 0 -0.4 0.1 0.3 -0.6 09/26/2004 15:10:00 4.9 0.8 6.1 3 5.1 0.9 6.5 3 0.4 0 0.4 0.4 1 11 350 305 0 0 0 0 -0.9 0.2 -0.4 -1.5 09/26/2004 15:20:00 4.5 0.5 5.7 3 4.6 0.6 5.7 3 0.4 0 0.4 0.4 3 5 359 305 0 0 0 0 -1.6 0.1 -1.1 -2 09/26/2004 15:30:00 3.9 0.6 4.9 2.6 4.1 0.6 5.3 3 0.4 0 0.4 0.4 8 7 20 305 0 0 0 0 -1.8 0 -1.3 -2 09/26/2004 15:40:00 3.2 0.5 4.2 1.5 3.4 0.5 4.6 2.3 0.4 0 0.4 0.4 12 7 4 305 0 0 0 0 -1.7 0.1 -1.1 -2 09/26/2004 15:50:00 3 0.4 4.2 1.9 3.1 0.4 4.2 2.3 0.4 0 0.4 0.4 20 7 23 305 0 0 0 0 -1.6 0.1 -1.1 -1.8 09/26/2004 16:00:00 3.3 0.4 4.2 2.3 3.5 0.4 4.6 2.3 0.4 0 0.4 0.4 27 6 29 305 0 0 0 0 -1 0.3 -0.1 -1.3 09/26/2004 16:10:00 3.2 0.5 4.2 2.3 3.4 0.5 4.6 1.9 0.4 0 0.4 0.4 19 7 26 305 0 0 0 0 -0.4 0.1 0.1 -0.6 09/26/2004 16:20:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 0.4 0 0.4 0.4 42 7 53 305 0 0 0 0 -0.1 0 0.3 -0.4 09/26/2004 16:30:00 2.3 0.5 3.4 0.7 2.5 0.5 3.8 1.1 0.4 0 0.4 0.4 36 8 35 305 0 0 0 0 0.1 0.1 0.6 -0.1 09/26/2004 16:40:00 2.5 0.6 3.8 1.1 2.7 0.6 4.6 1.5 0.4 0 0.4 0.4 29 19 29 305 0 0 0 0 0.2 0.1 0.6 0.1 09/26/2004 16:50:00 2.1 1 4.9 0.4 2.3 1 4.9 0.4 0.4 0 0.4 0.4 20 20 6 305 0 0 0 0 0.4 0.2 1.3 0.1 09/26/2004 17:00:00 3.5 0.8 5.3 1.5 3.7 0.9 5.7 1.5 0.4 0 0.4 0.4 355 7 343 305 0 0 0 0 0.6 0.1 1.3 0.3 09/26/2004 17:10:00 3.2 0.5 4.6 1.9 3.3 0.5 4.6 2.3 0.4 0 0.4 0.4 0 13 10 305 0 0 0 0 0.4 0.2 1 0.1 09/26/2004 17:20:00 3.8 0.5 5.3 2.3 3.9 0.5 5.3 2.6 0.4 0 0.4 0.4 339 11 340 305 0 0 0 0 0.1 0.1 0.6 0.1 09/26/2004 17:30:00 3 0.7 4.2 1.1 3.2 0.7 4.6 1.5 0.4 0 0.4 0.4 332 13 326 305 0 0 0 0 0 0.1 0.6 0.1 09/26/2004 17:40:00 2 1.2 4.9 0.4 2.2 1.1 5.3 0.4 0.4 0 0.4 0.4 332 17 318 305 0 0 0 0 0.1 0.1 0.6 0.1 09/26/2004 17:50:00 3.6 0.7 5.3 1.5 3.8 0.7 5.3 1.9 0.4 0 0.4 0.4 332 8 326 305 0 0 0 0 0.1 0.1 0.6 0.1 09/26/2004 18:00:00 3.2 0.8 4.9 1.1 3.4 0.8 5.3 1.1 0.4 0 0.4 0.4 330 10 336 305 0 0 0 0 0.4 0.2 1 0.1 09/26/2004 18:10:00 4 0.7 5.7 2.3 4.2 0.7 5.7 2.6 0.4 0 0.4 0.4 323 7 305 305 0 0 0 0 0.7 0.1 1.3 0.6 09/26/2004 18:20:00 2.6 1.2 4.9 0.4 2.7 1.1 4.6 0.7 0.4 0 0.4 0.4 313 6 305 305 0 0 0 0 1 0.1 1.5 0.8 09/26/2004 18:30:00 3.3 1.2 5.3 1.1 3.4 1 5.3 1.1 0.4 0 0.4 0.4 304 8 308 305 0 0 0 0 1.2 0.1 1.7 1 09/26/2004 18:40:00 2.4 0.7 3.8 0.4 2.5 0.7 4.2 1.1 0.4 0 0.4 0.4 316 9 324 305 0 0 0 0 0.7 0.2 1.5 0.3 09/26/2004 18:50:00 0.4 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.4 0 0.4 0.4 301 15 322 305 0 0 0 0 0.6 0.2 1.3 0.3 09/26/2004 19:00:00 2.5 0.4 3.8 1.1 2.7 0.4 3.8 1.5 0.4 0 0.4 0.4 338 11 335 305 0 0 0 0 0.4 0.2 1.3 0.1 09/26/2004 19:10:00 1.9 0.8 3.8 0.4 2.2 0.7 4.2 1.1 0.4 0 0.4 0.4 358 11 341 305 0 0 0 0 0 0.1 0.6 -0.1 09/26/2004 19:20:00 2 0.8 3.8 0.4 2.2 0.7 4.2 0.7 0.4 0 0.4 0.4 325 15 319 305 0 0 0 0 0 0 0.3 -0.1 09/26/2004 19:30:00 1 0.8 3 0.4 1.3 0.8 3 0.4 0.4 0 0.4 0.4 334 9 329 305 0 0 0 0 0 0 0.3 -0.4 09/26/2004 19:40:00 1.4 0.5 2.3 0.4 1.7 0.5 2.6 0.4 0.4 0 0.4 0.4 358 12 353 305 0 0 0 0 -0.1 0 0.3 -0.4 09/26/2004 19:50:00 1.2 0.6 2.6 0.4 1.6 0.5 3 0.4 0.4 0 0.4 0.4 353 13 319 305 0 0 0 0 0 0 0.3 -0.4 09/26/2004 20:00:00 1.4 0.8 3 0.4 1.8 0.7 3.4 0.7 0.4 0 0.4 0.4 349 15 16 305 0 0 0 0 -0.1 0 0.3 -0.1 09/26/2004 20:10:00 0.6 0.4 1.9 0.4 1.2 0.4 2.6 0.4 0.4 0 0.4 0.4 22 5 10 305 0 0 0 0 0 0 0.3 -0.1 09/26/2004 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 0 305 305 0 0 0 0 -0.2 0.1 0.3 -0.4 09/26/2004 20:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 6 21 305 305 0 0 0 0 -0.5 0.1 0.1 -0.6 09/26/2004 20:40:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 342 4 355 305 0 0 0 0 -0.5 0.1 0.1 -0.6 09/26/2004 20:50:00 0.4 0.1 1.1 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 349 11 355 305 0 0 0 0 -0.6 0.1 0.1 -0.8 09/26/2004 21:00:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 296 14 305 305 0 0 0 0 -0.8 0 -0.4 -1.1 09/26/2004 21:10:00 0.9 0.4 1.9 0.4 1.4 0.3 2.3 0.7 0.4 0 0.4 0.4 197 13 197 305 0 0 0 0 -1 0.1 -0.4 -1.1 09/26/2004 21:20:00 0.4 0.2 1.1 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 195 6 184 305 0 0 0 0 -1.1 0 -0.6 -1.3 09/26/2004 21:30:00 0.4 0.2 1.1 0.4 0.8 0.5 1.9 0.4 0.4 0 0.4 0.4 185 5 185 305 0 0 0 0 -1.4 0.2 -0.6 -2 09/26/2004 21:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 183 0 305 305 0 0 0 0 -1.9 0.1 -1.5 -2.2 09/26/2004 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 183 0 305 305 0 0 0 0 -2.3 0 -1.8 -2.4 09/26/2004 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 183 0 305 305 0 0 0 0 -2.3 0 -2 -2.4 09/26/2004 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 183 0 305 305 0 0 0 0 -2.2 0 -1.8 -2.4 09/26/2004 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 183 0 305 305 0 0 0 0 -2.3 0 -2 -2.4 09/26/2004 22:30:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 184 0 305 305 0 0 0 0 -2.5 0 -2 -2.7 09/26/2004 22:40:00 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 184 0 305 305 0 0 0 0 -1.9 0.2 -1.1 -2.4 09/26/2004 22:50:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 184 0 305 305 0 0 0 0 -2.3 0.2 -1.8 -2.7 09/26/2004 23:00:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 184 0 305 305 0 0 0 0 -2.7 0.1 -2.2 -2.7 09/26/2004 23:10:00 0.4 0.1 1.1 0.4 1 0.3 1.9 0.4 0.4 0 0.4 0.4 183 0 183 305 0 0 0 0 -2.3 0.4 -1.3 -2.7 09/26/2004 23:20:00 0.4 0.1 1.1 0.4 0.9 0.2 1.5 0.4 0.4 0 0.4 0.4 183 0 183 305 0 0 0 0 -2.1 0.2 -1.3 -2.7 09/26/2004 23:30:00 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 183 0 305 305 0 0 0 0 -2.6 0.1 -2 -2.7 09/26/2004 23:40:00 0.4 0.1 0.7 0.4 0.9 0.5 1.9 0.4 0.4 0 0.4 0.4 182 3 183 305 0 0 0 0 -2.8 0.1 -2.2 -3.1 09/26/2004 23:50:00 0.4 0.1 0.7 0.4 0.9 0.4 1.5 0.4 0.4 0 0.4 0.4 171 0 171 305 0 0 0 0 -3 0.2 -2.4 -3.3 09/27/2004 00:00:00 1.1 0.3 1.9 0.4 1.6 0.3 2.3 1.1 0.4 0 0.4 0.4 181 4 183 305 0 0 0 0 -2.4 0.3 -2 -3.1 09/27/2004 00:10:00 0.5 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.4 0 0.4 0.4 161 8 159 305 0 0 0 0 -2.6 0.2 -2 -2.9 09/27/2004 00:20:00 0.5 0.2 1.5 0.4 1.2 0.4 1.9 0.4 0.4 0 0.4 0.4 178 5 192 305 0 0 0 0 -2.7 0.1 -2.2 -2.9 09/27/2004 00:30:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 193 0 193 305 0 0 0 0 -2.6 0.1 -2 -2.7 09/27/2004 00:40:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 193 0 305 305 0 0 0 0 -2.7 0.1 -2.2 -2.7 09/27/2004 00:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 193 0 305 305 0 0 0 0 -2.4 0.2 -2 -2.7 09/27/2004 01:00:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 193 0 305 305 0 0 0 0 -2.8 0.1 -2 -3.1 09/27/2004 01:10:00 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 197 1 197 305 0 0 0 0 -2 0.1 -1.5 -2.4 09/27/2004 01:20:00 1.2 0.4 2.3 0.4 1.9 0.3 2.3 1.5 0.4 0 0.4 0.4 194 4 196 305 0 0 0 0 -1.8 0 -1.3 -2 09/27/2004 01:30:00 1.2 0.4 1.9 0.4 1.7 0.4 2.6 0.4 0.4 0 0.4 0.4 194 9 194 305 0 0 0 0 -2.1 0.1 -1.5 -2.4 09/27/2004 01:40:00 1.2 0.5 2.3 0.4 1.8 0.5 2.6 0.4 0.4 0 0.4 0.4 190 9 192 305 0 0 0 0 -2.2 0.1 -1.8 -2.4 09/27/2004 01:50:00 1 1 4.6 0.4 0.9 0.8 3.8 0.4 0.4 0 0.4 0.4 228 41 302 305 0 0 0 0 -2 0.2 -1.3 -2.4 09/27/2004 02:00:00 4.7 0.8 6.5 1.9 4.2 1 6.1 0.7 0.4 0 0.4 0.4 301 7 306 305 0 0 0 0 -1.6 0 -1.1 -1.8 09/27/2004 02:10:00 6.2 1 8 4.2 6 1 8 4.2 0.4 0 0.4 0.4 310 11 306 305 0 0 0 0 -0.7 0.3 0.1 -1.3 09/27/2004 02:20:00 6.7 0.9 9.1 4.9 6.5 0.9 8.8 4.2 0.4 0 0.4 0.4 308 12 316 305 0 0 0 0 -0.8 0.1 -0.1 -1.1 09/27/2004 02:30:00 7.2 0.8 9.5 4.9 7 0.9 9.1 4.9 0.4 0 0.4 0.4 311 6 305 305 0 0 0 0 -0.4 0.1 0.1 -0.6 09/27/2004 02:40:00 7 0.8 9.1 5.3 6.9 0.9 8.8 4.9 0.4 0 0.4 0.4 314 13 307 305 0 0 0 0 -0.4 0.1 0.1 -0.6 09/27/2004 02:50:00 5.9 0.8 7.6 4.2 5.9 0.8 7.2 3.8 0.4 0 0.4 0.4 311 9 305 305 0 0 0 0 -0.4 0.1 0.1 -0.6 09/27/2004 03:00:00 6.1 0.8 7.6 4.2 6.2 0.9 8 4.2 0.4 0 0.4 0.4 324 6 325 305 0 0 0 0 -0.3 0.1 0.1 -0.6 09/27/2004 03:10:00 5.4 1 7.6 3.8 5.5 1 8 3.4 0.4 0 0.4 0.4 322 7 321 305 0 0 0 0 -0.3 0 0.1 -0.6 09/27/2004 03:20:00 5.8 0.7 7.6 4.2 5.9 0.7 7.6 4.6 0.4 0 0.4 0.4 331 9 313 305 0 0 0 0 -0.2 0 0.3 -0.4 09/27/2004 03:30:00 5.7 0.7 7.6 3.8 5.9 0.7 7.6 4.2 0.4 0 0.4 0.4 344 5 337 305 0 0 0 0 -0.1 0 0.1 -0.4 09/27/2004 03:40:00 5.5 0.7 6.8 3.8 5.7 0.8 7.6 3.8 0.4 0 0.4 0.4 335 7 332 305 0 0 0 0 0 0 0.3 -0.1 09/27/2004 03:50:00 5.9 0.6 8 4.2 6.2 0.7 8.4 4.9 0.4 0 0.4 0.4 333 7 323 305 0 0 0 0 0 0.1 0.6 -0.1 09/27/2004 04:00:00 6.1 0.8 7.6 4.2 6.3 0.9 7.6 3.8 0.4 0 0.4 0.4 326 5 328 305 0 0 0 0 0 0 0.6 -0.1 09/27/2004 04:10:00 5.7 0.9 8 3.8 5.9 0.9 8 4.2 0.4 0 0.4 0.4 333 5 327 305 0 0 0 0 0 0 0.6 -0.1 09/27/2004 04:20:00 5.3 0.8 6.8 3.8 5.6 0.8 7.6 3.8 0.4 0 0.4 0.4 336 6 334 305 0 0 0 0 0.1 0.1 0.6 0.1 09/27/2004 04:30:00 5.9 0.9 8.4 4.2 6.1 0.9 8.4 4.6 0.4 0 0.4 0.4 338 5 341 305 0 0 0 0 0.2 0.1 0.6 0.1 09/27/2004 04:40:00 5.6 0.6 6.8 4.2 5.7 0.6 7.6 4.2 0.4 0 0.4 0.4 346 11 335 305 0 0 0 0 0.1 0 0.6 0.1 09/27/2004 04:50:00 5.3 0.6 6.5 3.4 5.5 0.6 7.2 3.8 0.4 0 0.4 0.4 337 8 348 305 0 0 0 0 0.2 0.1 0.6 0.1 09/27/2004 05:00:00 5.2 0.7 6.8 3.4 5.4 0.7 6.8 3.8 0.4 0 0.4 0.4 333 8 336 305 0 0 0 0 0.1 0.1 0.6 0.1 09/27/2004 05:10:00 5 0.8 6.8 3 5.2 0.9 7.2 3 0.4 0 0.4 0.4 333 12 330 305 0 0 0 0 0 0 0.6 -0.1 09/27/2004 05:20:00 4.9 0.6 6.1 3.4 5 0.6 6.5 3.4 0.4 0 0.4 0.4 321 11 337 305 0 0 0 0 -0.1 0.1 0.3 -0.4 09/27/2004 05:30:00 4.2 1 6.8 2.6 4.4 1 6.8 2.6 0.4 0 0.4 0.4 330 9 330 305 0 0 0 0 0 0 0.6 -0.1 09/27/2004 05:40:00 4.6 0.6 5.7 3 4.7 0.7 6.1 3 0.4 0 0.4 0.4 316 6 316 305 0 0 0 0 0 0 0.3 -0.1 09/27/2004 05:50:00 4.6 0.6 6.1 3 4.7 0.6 6.1 3 0.4 0 0.4 0.4 309 10 294 305 0 0 0 0 -0.1 0.1 0.6 -0.4 09/27/2004 06:00:00 4.4 0.5 5.3 3 4.4 0.5 5.3 3 0.4 0 0.4 0.4 304 7 308 305 0 0 0 0 -0.4 0.1 0.1 -0.6 09/27/2004 06:10:00 4 0.6 5.7 2.3 3.6 0.6 4.9 1.9 0.4 0 0.4 0.4 285 5 283 305 0 0 0 0 -0.6 0 -0.4 -0.6 09/27/2004 06:20:00 4.5 0.6 6.1 3.4 3.8 0.5 5.3 2.6 0.4 0 0.4 0.4 276 6 270 305 0 0 0 0 -0.4 0 -0.1 -0.6 09/27/2004 06:30:00 5.6 0.6 6.8 4.2 4.8 0.6 6.1 3 0.4 0 0.4 0.4 282 7 285 305 0 0 0 0 -0.3 0 0.1 -0.4 09/27/2004 06:40:00 6.6 0.8 9.1 4.9 5.9 0.8 8 4.2 0.4 0 0.4 0.4 282 7 286 305 0 0 0 0 0.1 0.1 0.3 -0.4 09/27/2004 06:50:00 7 1 9.1 4.6 6.1 1 8.8 3.4 0.4 0 0.4 0.4 282 7 273 305 0 0 0 0 0.4 0 0.6 0.1 09/27/2004 07:00:00 9.1 1.1 11.8 6.8 8.6 1.2 11.5 6.1 0.4 0 0.4 0.4 297 12 294 305 0 0 0 0 0.6 0 1 0.6 09/27/2004 07:10:00 9.8 1 12.2 6.8 9.4 1 11.8 6.5 0.4 0 0.4 0.4 298 9 304 305 0 0 0 0 0.6 0 1 0.6 09/27/2004 07:20:00 10.6 1 13 7.6 10 1.1 13 7.2 0.4 0 0.4 0.4 298 8 302 305 0 0 0 0 0.6 0 1 0.6 09/27/2004 07:30:00 10.7 1.3 13.7 7.2 10.2 1.3 13.7 7.2 0.4 0 0.4 0.4 296 7 294 305 0 0 0 0 0.5 0 0.6 0.3 09/27/2004 07:40:00 10.6 1.2 14.1 7.6 10.1 1.3 13.7 6.8 0.4 0 0.4 0.4 297 7 293 305 0 0 0 0 0.6 0 0.8 0.6 09/27/2004 07:50:00 11.2 1.2 14.1 7.6 10.5 1.3 13.7 7.6 0.4 0 0.4 0.4 294 8 293 305 0 0 0 0 0.6 0 1 0.6 09/27/2004 08:00:00 10.9 1.1 13.7 7.2 10.1 1.2 13.7 7.2 0.4 0 0.4 0.4 291 7 302 305 0 0 0 0 0.8 0 1.3 0.6 09/27/2004 08:10:00 12 1.2 14.5 8 11.3 1.3 14.5 7.6 0.4 0 0.4 0.4 295 6 296 305 0 0 0 0 0.8 0 1.3 0.6 09/27/2004 08:20:00 11.5 1.1 14.1 9.1 11 1.2 13.3 7.6 0.4 0 0.4 0.4 302 9 2 305 0 0 0 0 0.7 0.1 1.3 0.6 09/27/2004 08:30:00 11.7 0.8 13.7 8.8 11.3 1 13.3 8.8 0.4 0 0.4 0.4 300 15 300 305 0 0 0 0 0.8 0 1.3 0.6 09/27/2004 08:40:00 11.3 0.8 13.3 9.1 10.8 1 13 8 0.4 0 0.4 0.4 304 13 302 305 0 0 0 0 0.8 0 1.3 0.6 09/27/2004 08:50:00 10.8 0.7 13 8.8 10.5 0.7 12.2 8.8 0.4 0 0.4 0.4 300 15 291 305 0 0 0 0 0.9 0 1.5 0.8 09/27/2004 09:00:00 10.2 0.8 11.8 8.4 10 0.8 11.8 8 0.4 0 0.4 0.4 309 8 305 305 0 0 0 0 1 0 1.5 1 09/27/2004 09:10:00 10.2 0.7 11.8 8.4 10 0.8 11.8 8 0.4 0 0.4 0.4 309 7 305 305 0 0 0 0 1 0 1.3 1 09/27/2004 09:20:00 10.1 0.6 12.2 8.4 9.9 0.8 12.2 7.6 0.4 0 0.4 0.4 309 14 306 305 0 0 0 0 1 0 1.3 1 09/27/2004 09:30:00 9.8 0.7 11.5 7.6 9.5 0.8 11.8 7.6 0.4 0 0.4 0.4 308 13 290 305 0 0 0 0 1 0 1.3 1 09/27/2004 09:40:00 9.5 0.7 11.1 7.2 9.1 0.8 11.1 6.8 0.4 0 0.4 0.4 305 15 298 305 0 0 0 0 0.9 0 1.3 0.8 09/27/2004 09:50:00 9 0.7 10.7 7.2 8.8 0.8 11.1 6.8 0.4 0 0.4 0.4 312 10 313 305 0 0 0 0 1 0 1.5 0.8 09/27/2004 10:00:00 8.6 0.5 9.9 6.8 8.4 0.6 9.5 6.8 0.4 0 0.4 0.4 308 11 307 305 0 0 0 0 1.1 0 1.5 1 09/27/2004 10:10:00 8.5 0.6 9.9 6.8 8.4 0.6 9.9 6.5 0.4 0 0.4 0.4 312 8 309 305 0 0 0 0 1.2 0.1 1.5 1 09/27/2004 10:20:00 7.7 0.8 9.1 5.3 7.8 0.9 9.1 5.3 0.4 0 0.4 0.4 320 6 319 305 0 0 0 0 1.2 0.1 1.5 1 09/27/2004 10:30:00 7.7 1 10.3 5.3 7.6 1 10.3 5.3 0.4 0 0.4 0.4 315 8 313 305 0 0 0 0 1.4 0 2 1.3 09/27/2004 10:40:00 8.2 0.8 11.1 6.1 8.2 0.8 10.7 5.7 0.4 0 0.4 0.4 319 8 309 305 0 0 0 0 1.5 0 2 1.3 09/27/2004 10:50:00 7.3 0.8 9.5 5.7 7.2 0.9 9.1 4.9 0.4 0 0.4 0.4 315 9 313 305 0 0 0 0 1.6 0.1 2 1.3 09/27/2004 11:00:00 7.1 1.1 10.3 4.9 7.2 1.2 10.7 4.9 0.4 0 0.4 0.4 322 7 306 305 0 0 0 0 1.5 0 2 1.3 09/27/2004 11:10:00 7.3 0.8 8.8 5.3 7.4 0.8 9.1 5.3 0.4 0 0.4 0.4 323 5 320 305 0 0 0 0 1.4 0.1 2 1.3 09/27/2004 11:20:00 6.7 0.8 8.8 4.9 6.8 0.8 8.4 5.3 0.4 0 0.4 0.4 324 6 316 305 0 0 0 0 1.6 0.1 2 1.3 09/27/2004 11:30:00 6.6 0.6 8 4.9 6.7 0.7 8 4.9 0.4 0 0.4 0.4 321 9 319 305 0 0 0 0 1.6 0.1 2 1.5 09/27/2004 11:40:00 6.9 0.6 8.8 5.3 6.9 0.6 9.1 5.3 0.4 0 0.4 0.4 317 11 323 305 0 0 0 0 1.6 0.1 2.2 1.5 09/27/2004 11:50:00 6.2 0.6 7.6 4.9 6.3 0.6 8 4.9 0.4 0 0.4 0.4 320 7 321 305 0 0 0 0 1.7 0.1 2 1.5 09/27/2004 12:00:00 6.1 0.8 8 4.2 6.2 0.8 8 3.8 0.4 0 0.4 0.4 322 7 321 305 0 0 0 0 1.9 0.2 2.5 1.5 09/27/2004 12:10:00 6.3 0.9 8 3.8 6.3 0.9 8.4 4.2 0.4 0 0.4 0.4 315 6 305 305 0 0 0 0 2 0.2 2.5 1.7 09/27/2004 12:20:00 6.4 0.9 8.8 4.6 6.4 0.9 8.8 4.6 0.4 0 0.4 0.4 320 6 320 305 0 0 0 0 2 0.1 2.5 1.7 09/27/2004 12:30:00 5.9 0.9 8.4 3.8 5.9 0.9 8 3.4 0.4 0 0.4 0.4 312 7 323 305 0 0 0 0 1.8 0.2 2.5 1.5 09/27/2004 12:40:00 6.4 0.7 8 4.6 6.3 0.7 8 4.6 0.4 0 0.4 0.4 309 10 306 305 0 0 0 0 2.3 0.2 2.7 2 09/27/2004 12:50:00 6.6 0.6 8.8 4.6 6.5 0.7 8.8 4.9 0.4 0 0.4 0.4 308 11 303 305 0 0 0 0 2.4 0.2 2.9 2.2 09/27/2004 13:00:00 6.4 0.8 8 4.2 6.4 0.9 8.4 3.8 0.4 0 0.4 0.4 307 6 310 305 0 0 0 0 2.5 0.1 2.9 2.2 09/27/2004 13:10:00 6.3 0.6 8 4.9 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 305 11 313 305 0 0 0 0 2.2 0.1 2.7 2 09/27/2004 13:20:00 6.4 0.6 8 4.9 6.3 0.6 8.4 4.6 0.4 0 0.4 0.4 302 14 304 305 0 0 0 0 2.4 0.1 2.9 2.2 09/27/2004 13:30:00 6.1 0.5 7.2 4.9 6 0.6 7.2 4.6 0.4 0 0.4 0.4 302 11 301 305 0 0 0 0 2.2 0 2.7 2 09/27/2004 13:40:00 6.3 0.6 8.4 4.9 6.2 0.6 8.4 4.6 0.4 0 0.4 0.4 302 10 307 305 0 0 0 0 2.6 0 3.2 2.5 09/27/2004 13:50:00 6.1 0.6 7.6 4.6 6 0.6 7.6 4.6 0.4 0 0.4 0.4 306 10 292 305 0 0 0 0 2.7 0.2 3.2 2.5 09/27/2004 14:00:00 5.7 0.6 7.2 4.6 5.7 0.6 7.2 4.2 0.4 0 0.4 0.4 305 7 302 305 0 0 0 0 2.9 0 3.2 2.7 09/27/2004 14:10:00 6.1 0.5 7.6 4.6 6 0.6 7.2 4.6 0.4 0 0.4 0.4 299 11 303 305 0 0 0 0 2.8 0 3.2 2.7 09/27/2004 14:20:00 6 0.6 7.6 4.2 5.9 0.6 7.2 4.2 0.4 0 0.4 0.4 303 13 297 305 0 0 0 0 3.1 0 3.4 2.9 09/27/2004 14:30:00 6.6 0.8 8.8 5.3 6.5 0.8 8.8 4.6 0.4 0 0.4 0.4 302 10 303 305 0 0 0 0 3.1 0 3.4 2.9 09/27/2004 14:40:00 6.6 0.7 8 4.9 6.5 0.7 8 4.9 0.4 0 0.4 0.4 300 11 302 305 0 0 0 0 3 0 3.4 2.9 09/27/2004 14:50:00 6.1 0.5 7.2 4.6 6.1 0.5 7.2 4.6 0.4 0 0.4 0.4 309 6 308 305 0 0 0 0 3.3 0 3.7 3.2 09/27/2004 15:00:00 5.8 0.6 7.6 3.8 5.8 0.6 7.2 3.8 0.4 0 0.4 0.4 302 6 307 305 0 0 0 0 3.3 0 3.7 3.2 09/27/2004 15:10:00 6.5 0.6 8 4.9 6.4 0.7 8 4.9 0.4 0 0.4 0.4 306 12 299 305 0 0 0 0 3.5 0.1 3.9 3.2 09/27/2004 15:20:00 6.4 0.5 7.6 4.6 6.3 0.5 7.2 4.9 0.4 0 0.4 0.4 306 8 305 305 0 0 0 0 3.4 0.1 3.7 3.2 09/27/2004 15:30:00 6.4 0.7 8 4.6 6.4 0.7 8 4.6 0.4 0 0.4 0.4 299 12 305 305 0 0 0 0 3.1 0.1 3.4 2.7 09/27/2004 15:40:00 6.7 0.8 8.8 4.6 6.4 0.8 8.8 4.6 0.4 0 0.4 0.4 299 9 303 305 0 0 0 0 3.3 0.1 3.7 2.9 09/27/2004 15:50:00 6.7 0.8 8.8 4.9 6.7 0.8 8.8 4.9 0.4 0 0.4 0.4 301 8 296 305 0 0 0 0 3.3 0.1 3.7 2.9 09/27/2004 16:00:00 7.2 0.5 8 5.7 7 0.6 8 5.3 0.4 0 0.4 0.4 300 5 287 305 0 0 0 0 3.1 0.1 3.4 2.9 09/27/2004 16:10:00 6.6 0.7 8.8 4.9 6.5 0.7 9.1 4.9 0.4 0 0.4 0.4 306 9 326 305 0 0 0 0 3.1 0 3.4 2.9 09/27/2004 16:20:00 6.7 0.7 8 4.6 6.7 0.7 8 4.6 0.4 0 0.4 0.4 308 10 305 305 0 0 0 0 2.9 0.1 3.4 2.7 09/27/2004 16:30:00 6.8 0.8 8.8 4.9 6.7 0.7 8.4 4.9 0.4 0 0.4 0.4 307 7 301 305 0 0 0 0 3 0.1 3.4 2.7 09/27/2004 16:40:00 8.7 1 11.1 6.5 8.6 1 10.7 6.1 0.4 0 0.4 0.4 311 6 311 305 0 0 0 0 3.2 0 3.4 2.9 09/27/2004 16:50:00 8.7 0.8 11.5 6.1 8.6 0.8 10.7 5.7 0.4 0 0.4 0.4 311 6 304 305 0 0 0 0 2.9 0.1 3.4 2.7 09/27/2004 17:00:00 8.3 1 11.1 6.1 8.1 1 10.3 5.7 0.4 0 0.4 0.4 308 6 310 305 0 0 0 0 2.6 0.1 3.2 2.2 09/27/2004 17:10:00 8.3 0.8 10.3 5.3 8.2 0.8 10.3 5.7 0.4 0 0.4 0.4 310 15 305 305 0 0 0 0 2.5 0.1 2.7 2.2 09/27/2004 17:20:00 8.5 0.7 10.3 6.5 8.4 0.8 10.3 6.5 0.4 0 0.4 0.4 315 12 305 305 0 0 0 0 2.8 0.2 3.2 2.5 09/27/2004 17:30:00 7.8 0.8 9.9 5.7 7.6 0.8 9.9 5.3 0.4 0 0.4 0.4 313 10 315 305 0 0 0 0 3.1 0.1 3.7 2.9 09/27/2004 17:40:00 7.9 0.8 10.3 6.1 7.9 0.9 9.9 5.7 0.4 0 0.4 0.4 316 6 321 305 0 0 0 0 3.3 0.1 3.7 2.9 09/27/2004 17:50:00 7.7 0.8 9.5 5.7 7.6 0.9 9.5 5.3 0.4 0 0.4 0.4 309 5 306 305 0 0 0 0 3.1 0.1 3.4 2.9 09/27/2004 18:00:00 7.8 0.7 9.5 6.1 7.7 0.8 9.9 5.7 0.4 0 0.4 0.4 311 9 305 305 0 0 0 0 3.4 0 3.7 3.2 09/27/2004 18:10:00 7.5 0.8 9.1 6.1 7.4 0.9 9.5 5.3 0.4 0 0.4 0.4 316 8 327 305 0 0 0 0 3.5 0.1 3.7 3.2 09/27/2004 18:20:00 9.4 1.3 12.2 6.8 9.3 1.3 12.2 6.5 0.4 0 0.4 0.4 314 17 310 305 0 0 0 0 2.8 0.4 3.4 2.2 09/27/2004 18:30:00 9.3 0.9 11.1 6.5 9.4 1.1 11.5 6.5 0.4 0 0.4 0.4 325 8 318 305 0 0 0 0 2.5 0 2.9 2.2 09/27/2004 18:40:00 8.5 0.7 10.7 6.8 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 338 4 332 305 0 0 0 0 2.2 0 2.9 2 09/27/2004 18:50:00 9.2 0.6 11.1 7.6 9.4 0.7 11.5 7.6 0.4 0 0.4 0.4 337 6 343 305 0 0 0 0 2 0 2.2 2 09/27/2004 19:00:00 9.5 0.8 12.6 8 9.6 0.8 12.6 7.6 0.4 0 0.4 0.4 332 5 330 305 0 0 0 0 1.6 0.1 2.2 1.3 09/27/2004 19:10:00 11.5 1 14.1 8.8 11.6 1.1 14.5 8.8 0.4 0 0.4 0.4 335 5 338 305 0 0 0 0 1.7 0.1 2.2 1.5 09/27/2004 19:20:00 12.6 1.1 15.3 9.9 12.9 1.1 15.3 9.9 0.4 0 0.4 0.4 344 4 346 305 0 0 0 0 1.9 0 2.5 1.7 09/27/2004 19:30:00 13.6 1.1 16.1 10.3 13.8 1.2 17.2 10.7 0.4 0 0.4 0.4 347 5 353 305 0 0 0 0 1.9 0.1 2.2 1.5 09/27/2004 19:40:00 13.6 0.8 15.3 10.7 13.8 0.8 15.6 10.3 0.4 0 0.4 0.4 347 4 345 305 0 0 0 0 1.8 0.1 2.2 1.5 09/27/2004 19:50:00 12.5 1 14.5 9.5 12.7 1 14.9 9.5 0.4 0 0.4 0.4 351 4 353 305 0 0 0 0 2 0.1 2.5 1.7 09/27/2004 20:00:00 13.1 0.8 14.9 11.1 13.4 0.9 15.3 10.7 0.4 0 0.4 0.4 351 3 350 305 0 0 0 0 1.9 0 2.5 1.7 09/27/2004 20:10:00 12.4 0.9 15.6 9.9 12.7 0.9 15.6 9.9 0.4 0 0.4 0.4 353 5 345 305 0 0 0 0 2 0 2.5 2 09/27/2004 20:20:00 12.7 1 14.9 9.5 12.9 1.1 15.6 9.9 0.4 0 0.4 0.4 353 6 350 305 0 0 0 0 2 0.1 2.5 2 09/27/2004 20:30:00 12.5 1 14.9 9.9 12.7 1.1 14.9 9.1 0.4 0 0.4 0.4 353 4 354 305 0 0 0 0 2.1 0 2.5 2 09/27/2004 20:40:00 11.9 1 14.1 9.1 12 1.1 14.9 8 0.4 0 0.4 0.4 354 5 350 305 0 0 0 0 2.2 0.1 2.5 2 09/27/2004 20:50:00 11.9 0.8 13.7 9.5 11.9 1 14.1 8.8 0.4 0 0.4 0.4 358 5 353 305 0 0 0 0 2.1 0 2.5 2 09/27/2004 21:00:00 11.9 1 14.5 9.1 12 1.1 14.5 9.5 0.4 0 0.4 0.4 1 5 5 305 0 0 0 0 2 0 2.5 2 09/27/2004 21:10:00 12.1 0.9 13.7 9.9 12.2 0.9 14.1 9.9 0.4 0 0.4 0.4 357 4 355 305 0 0 0 0 2 0 2.5 2 09/27/2004 21:20:00 11.6 0.9 14.1 9.1 11.7 1.1 14.9 9.5 0.4 0 0.4 0.4 355 9 345 305 0 0 0 0 2 0 2.5 2 09/27/2004 21:30:00 11.7 0.7 13.3 9.9 11.9 0.8 13.7 9.5 0.4 0 0.4 0.4 351 4 347 305 0 0 0 0 1.9 0 2.5 1.7 09/27/2004 21:40:00 11.6 0.9 13.3 9.1 11.7 1 14.1 8.8 0.4 0 0.4 0.4 1 5 2 305 0 0 0 0 2.1 0.1 2.5 2 09/27/2004 21:50:00 11.3 0.9 13.3 9.1 11.5 1 13.7 8.4 0.4 0 0.4 0.4 357 4 359 305 0 0 0 0 2.2 0.1 2.7 2 09/27/2004 22:00:00 10.1 1 12.2 7.6 10.3 1 12.6 7.6 0.4 0 0.4 0.4 350 5 351 305 0 0 0 0 2.2 0.1 2.7 2 09/27/2004 22:10:00 10 0.8 11.8 7.6 10.3 0.9 12.2 8 0.4 0 0.4 0.4 346 5 339 305 0 0 0 0 2.1 0 2.5 2 09/27/2004 22:20:00 10.4 0.7 12.2 8 10.5 0.8 12.6 8.8 0.4 0 0.4 0.4 350 3 345 305 0 0 0 0 2 0 2.5 2 09/27/2004 22:30:00 10.5 0.7 12.2 8.4 10.8 0.6 12.2 9.1 0.4 0 0.4 0.4 347 4 343 305 0 0 0 0 2 0 2.5 2 09/27/2004 22:40:00 10.2 0.8 12.2 8 10.5 0.8 12.2 8 0.4 0 0.4 0.4 347 5 344 305 0 0 0 0 2 0 2.5 2 09/27/2004 22:50:00 10.2 0.8 12.2 7.6 10.5 0.9 13 8.4 0.4 0 0.4 0.4 348 4 340 305 0 0 0 0 2.1 0 2.5 2 09/27/2004 23:00:00 10.1 0.8 12.2 8.4 10.4 0.8 13 8 0.4 0 0.4 0.4 348 3 348 305 0 0 0 0 2 0 2.5 2 09/27/2004 23:10:00 9.6 0.9 11.5 7.2 9.8 0.9 11.8 7.2 0.4 0 0.4 0.4 346 6 344 305 0 0 0 0 2.1 0 2.5 2 09/27/2004 23:20:00 9 0.6 11.1 7.2 9.3 0.7 11.1 7.2 0.4 0 0.4 0.4 335 6 337 305 0 0 0 0 2 0 2.5 2 09/27/2004 23:30:00 8.9 0.8 11.5 6.8 9.2 0.8 11.8 6.8 0.4 0 0.4 0.4 338 5 336 305 0 0 0 0 2 0.1 2.5 2 09/27/2004 23:40:00 9.8 1.3 13.3 7.6 10.1 1.3 13.7 7.6 0.4 0 0.4 0.4 351 5 351 305 0 0 0 0 2.1 0.1 2.7 2 09/27/2004 23:50:00 10.2 0.8 12.2 8 10.5 1 12.6 8 0.4 0 0.4 0.4 352 5 349 305 0 0 0 0 2.2 0.1 2.7 2 09/28/2004 00:00:00 10.4 1.1 13 7.6 10.6 1 13.3 8 0.4 0 0.4 0.4 342 4 345 305 0 0 0 0 2.2 0 2.7 2.2 09/28/2004 00:10:00 11.1 0.8 13 8.8 11.4 0.8 13 9.1 0.4 0 0.4 0.4 352 6 341 305 0 0 0 0 2 0 2.7 2 09/28/2004 00:20:00 10.9 0.9 13 8.4 11.2 1 13 8.4 0.4 0 0.4 0.4 348 7 355 305 0 0 0 0 2.2 0.1 2.7 2 09/28/2004 00:30:00 11.5 0.8 13.7 9.1 11.7 0.8 13.7 9.9 0.4 0 0.4 0.4 345 8 358 305 0 0 0 0 2 0 2.5 2 09/28/2004 00:40:00 12.4 1.2 14.9 9.5 12.6 1.2 15.3 9.5 0.4 0 0.4 0.4 351 3 350 305 0 0 0 0 1.9 0.1 2.5 1.5 09/28/2004 00:50:00 12.2 1.1 14.5 9.9 12.3 1.2 14.9 9.1 0.4 0 0.4 0.4 353 6 352 305 0 0 0 0 1.9 0.1 2.5 1.7 09/28/2004 01:00:00 11.9 1.2 14.5 9.1 12.1 1.3 14.9 8.4 0.4 0 0.4 0.4 347 6 349 305 0 0 0 0 1.9 0.1 2.5 1.7 09/28/2004 01:10:00 12.3 1 14.1 9.5 12.5 1 14.9 9.5 0.4 0 0.4 0.4 347 5 337 305 0 0 0 0 1.7 0.1 2.2 1.5 09/28/2004 01:20:00 12.5 1 14.5 9.9 12.8 1.1 15.3 9.9 0.4 0 0.4 0.4 351 4 348 305 0 0 0 0 1.7 0.1 2.2 1.5 09/28/2004 01:30:00 12.2 1 14.1 9.5 12.5 1 14.5 9.1 0.4 0 0.4 0.4 349 4 350 305 0 0 0 0 1.7 0.1 2.2 1.5 09/28/2004 01:40:00 12.3 1.3 15.6 8.8 12.6 1.3 15.3 8.8 0.4 0 0.4 0.4 351 6 345 305 0 0 0 0 1.6 0 2.2 1.5 09/28/2004 01:50:00 11.8 1.1 13.7 9.1 12 1.1 14.1 9.5 0.4 0 0.4 0.4 350 5 344 305 0 0 0 0 1.6 0 2.2 1.5 09/28/2004 02:00:00 11.9 1 14.5 9.5 12.2 1.1 14.9 8.4 0.4 0 0.4 0.4 351 5 345 305 0 0 0 0 1.6 0 2 1.5 09/28/2004 02:10:00 12 1.1 14.1 9.1 12.2 1.2 14.5 9.1 0.4 0 0.4 0.4 347 5 341 305 0 0 0 0 1.6 0 2 1.3 09/28/2004 02:20:00 11.7 0.8 13.3 9.1 11.9 0.8 14.1 9.9 0.4 0 0.4 0.4 351 4 350 305 0 0 0 0 1.5 0 2 1.3 09/28/2004 02:30:00 11.3 0.8 13 8.8 11.5 0.9 13.3 8.8 0.4 0 0.4 0.4 352 4 358 305 0 0 0 0 1.5 0 2 1.3 09/28/2004 02:40:00 10.8 0.8 12.6 8.4 11.1 0.9 13 8 0.4 0 0.4 0.4 350 6 347 305 0 0 0 0 1.4 0 2 1.3 09/28/2004 02:50:00 10.7 0.8 12.6 8.4 11 1 13 8 0.4 0 0.4 0.4 348 5 343 305 0 0 0 0 1.4 0 2 1.3 09/28/2004 03:00:00 10.8 0.8 13 8.8 11 1 13.3 8 0.4 0 0.4 0.4 354 5 356 305 0 0 0 0 1.4 0 2 1.3 09/28/2004 03:10:00 10 1 12.2 7.6 10.2 1 12.6 7.6 0.4 0 0.4 0.4 349 5 351 305 0 0 0 0 1.5 0 2 1.3 09/28/2004 03:20:00 9.1 0.7 11.1 7.2 9.5 0.7 11.5 7.6 0.4 0 0.4 0.4 342 6 340 305 0 0 0 0 1.5 0 2.2 1.3 09/28/2004 03:30:00 9.4 0.7 11.1 7.2 9.6 0.7 11.5 7.2 0.4 0 0.4 0.4 352 4 354 305 0 0 0 0 1.6 0 2.2 1.5 09/28/2004 03:40:00 10.1 0.7 11.8 8.4 10.4 0.8 12.6 8.8 0.4 0 0.4 0.4 355 4 352 305 0 0 0 0 1.4 0.1 2 1.3 09/28/2004 03:50:00 9.1 0.6 10.3 7.2 9.4 0.6 10.7 7.2 0.4 0 0.4 0.4 354 5 351 305 0 0 0 0 1.4 0.1 2 1.3 09/28/2004 04:00:00 8.7 0.7 10.3 6.5 8.9 0.8 10.7 6.5 0.4 0 0.4 0.4 348 6 352 305 0 0 0 0 1.3 0.1 1.7 1 09/28/2004 04:10:00 8.7 0.7 10.3 6.8 9 0.7 10.7 6.8 0.4 0 0.4 0.4 345 4 344 305 0 0 0 0 1.2 0.1 1.7 1 09/28/2004 04:20:00 8.7 0.6 11.1 7.2 9 0.7 11.8 7.2 0.4 0 0.4 0.4 346 6 347 305 0 0 0 0 1.2 0.1 1.5 1 09/28/2004 04:30:00 8.2 0.8 10.7 6.1 8.4 0.8 11.1 6.1 0.4 0 0.4 0.4 349 5 341 305 0 0 0 0 1.1 0.1 1.5 1 09/28/2004 04:40:00 8.3 0.7 11.1 6.8 8.6 0.8 11.1 6.8 0.4 0 0.4 0.4 347 6 341 305 0 0 0 0 1.1 0.1 1.5 1 09/28/2004 04:50:00 7.6 0.8 9.5 5.7 7.8 0.9 9.9 5.7 0.4 0 0.4 0.4 347 6 352 305 0 0 0 0 1 0 1.5 0.8 09/28/2004 05:00:00 7.4 0.8 9.1 5.7 7.7 0.9 9.9 5.7 0.4 0 0.4 0.4 350 5 353 305 0 0 0 0 1 0 1.5 0.8 09/28/2004 05:10:00 8 0.6 9.9 6.5 8.3 0.6 9.9 6.8 0.4 0 0.4 0.4 350 6 359 305 0 0 0 0 1 0 1.5 0.8 09/28/2004 05:20:00 8.2 0.7 9.9 6.1 8.4 0.8 10.3 5.7 0.4 0 0.4 0.4 346 7 336 305 0 0 0 0 0.9 0.1 1.5 0.8 09/28/2004 05:30:00 7.9 0.7 9.5 6.5 8.1 0.8 9.9 6.5 0.4 0 0.4 0.4 343 6 344 305 0 0 0 0 0.9 0.1 1.3 0.6 09/28/2004 05:40:00 7.7 0.9 9.9 5.3 7.9 1 10.3 5.7 0.4 0 0.4 0.4 342 6 342 305 0 0 0 0 0.7 0.1 1.3 0.6 09/28/2004 05:50:00 7.6 0.8 9.5 5.7 7.9 0.8 9.9 5.7 0.4 0 0.4 0.4 338 6 333 305 0 0 0 0 0.6 0.2 1.3 0.6 09/28/2004 06:00:00 7.8 0.8 9.9 5.7 8 0.8 10.7 5.7 0.4 0 0.4 0.4 345 5 344 305 0 0 0 0 0.6 0.1 1.3 0.6 09/28/2004 06:10:00 6.8 0.6 8.8 5.3 7 0.7 9.1 5.3 0.4 0 0.4 0.4 339 8 325 305 0 0 0 0 0.6 0.2 1.3 0.6 09/28/2004 06:20:00 6.9 0.8 8.8 5.3 7.1 0.8 9.5 4.9 0.4 0 0.4 0.4 332 8 319 305 0 0 0 0 0.6 0.1 1 0.6 09/28/2004 06:30:00 6.9 0.5 8.4 5.7 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 337 6 338 305 0 0 0 0 0.7 0.1 1.3 0.6 09/28/2004 06:40:00 6.5 0.7 8.8 4.9 6.7 0.7 8.8 4.9 0.4 0 0.4 0.4 335 5 339 305 0 0 0 0 0.8 0 1.3 0.6 09/28/2004 06:50:00 6.5 0.7 8.8 4.9 6.6 0.8 8.4 4.9 0.4 0 0.4 0.4 334 6 338 305 0 0 0 0 0.9 0 1.5 0.6 09/28/2004 07:00:00 7 0.5 8.4 5.7 7.3 0.6 9.1 5.7 0.4 0 0.4 0.4 335 5 329 305 0 0 0 0 1 0 1.5 1 09/28/2004 07:10:00 6.2 0.5 7.6 4.6 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 332 5 336 305 0 0 0 0 1 0 1.5 1 09/28/2004 07:20:00 6 0.4 7.2 5.3 6.2 0.4 7.2 5.3 0.4 0 0.4 0.4 335 5 332 305 0 0 0 0 1.1 0.1 1.5 1 09/28/2004 07:30:00 5.2 0.4 6.1 3.8 5.3 0.4 6.1 4.2 0.4 0 0.4 0.4 327 6 333 305 0 0 0 0 1.1 0 1.5 1 09/28/2004 07:40:00 4.5 0.5 6.1 3.4 4.6 0.5 5.7 3.4 0.4 0 0.4 0.4 326 7 320 305 0 0 0 0 1.1 0 1.5 1 09/28/2004 07:50:00 3.9 0.6 5.3 2.6 3.9 0.5 4.9 2.6 0.4 0 0.4 0.4 319 11 310 305 0 0 0 0 1 0 1.5 0.8 09/28/2004 08:00:00 5.5 0.9 6.8 3 5.3 0.8 6.5 3.4 0.4 0 0.4 0.4 302 6 298 305 0 0 0 0 0.7 0.2 1.3 0.6 09/28/2004 08:10:00 5.1 0.6 6.1 4.2 4.8 0.5 6.1 3.8 0.4 0 0.4 0.4 297 11 293 305 0 0 0 0 0.5 0 1 0.3 09/28/2004 08:20:00 4.6 0.4 6.1 3.8 4.3 0.5 5.7 3 0.4 0 0.4 0.4 296 7 310 305 0 0 0 0 0.3 0.1 0.8 0.1 09/28/2004 08:30:00 4.9 0.6 6.1 3.4 4.7 0.6 5.7 3 0.4 0 0.4 0.4 301 6 305 305 0 0 0 0 0.4 0.1 1 0.1 09/28/2004 08:40:00 4.8 0.6 6.5 3.4 4.7 0.6 6.5 3.4 0.4 0 0.4 0.4 306 5 307 305 0 0 0 0 0.4 0 1 0.3 09/28/2004 08:50:00 4.9 0.6 6.8 3.4 4.7 0.6 6.5 3.4 0.4 0 0.4 0.4 309 12 303 305 0 0 0 0 0.6 0.1 1 0.6 09/28/2004 09:00:00 5 0.6 6.5 3.8 5 0.6 6.5 3.8 0.4 0 0.4 0.4 311 9 310 305 0 0 0 0 1 0.1 1.3 0.8 09/28/2004 09:10:00 5.2 0.5 6.1 3.8 5.4 0.5 6.5 4.2 0.4 0 0.4 0.4 326 5 330 305 0 0 0 0 1.3 0 1.5 1 09/28/2004 09:20:00 4.9 0.7 6.5 3.4 5 0.8 6.5 3 0.4 0 0.4 0.4 329 11 319 305 0 0 0 0 1.5 0 2 1.3 09/28/2004 09:30:00 5.7 0.7 7.2 3.8 5.8 0.8 7.2 3 0.4 0 0.4 0.4 327 7 330 305 0 0 0 0 1.6 0 2 1.5 09/28/2004 09:40:00 3.3 0.8 6.1 1.9 3.4 0.9 6.1 1.9 0.4 0 0.4 0.4 312 6 320 305 0 0 0 0 1.4 0.1 2 1.3 09/28/2004 09:50:00 4.3 0.8 5.7 2.3 4.3 0.8 5.7 2.3 0.4 0 0.4 0.4 320 5 312 305 0 0 0 0 1.3 0 2 1.3 09/28/2004 10:00:00 5 0.5 6.1 3.4 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 323 6 320 305 0 0 0 0 1.6 0.1 2.2 1.5 09/28/2004 10:10:00 5 0.6 6.1 3.4 5.1 0.7 6.5 3.4 0.4 0 0.4 0.4 329 5 322 305 0 0 0 0 1.9 0 2.5 1.7 09/28/2004 10:20:00 6.3 0.8 8 4.2 6.5 0.8 8 4.6 0.4 0 0.4 0.4 329 5 322 305 0 0 0 0 1.7 0.1 2.2 1.5 09/28/2004 10:30:00 5.7 0.8 7.2 3 5.8 0.8 7.6 3.4 0.4 0 0.4 0.4 322 6 323 305 0 0 0 0 1.6 0.1 2.2 1.5 09/28/2004 10:40:00 6.2 0.8 8 4.6 6.3 0.8 8 4.6 0.4 0 0.4 0.4 324 6 329 305 0 0 0 0 1.6 0.1 2.2 1.5 09/28/2004 10:50:00 7.3 0.7 8.8 5.3 7.5 0.8 9.1 5.3 0.4 0 0.4 0.4 327 5 329 305 0 0 0 0 1.3 0.3 2.2 1 09/28/2004 11:00:00 6.6 0.5 7.6 4.9 6.7 0.5 8 4.9 0.4 0 0.4 0.4 323 6 306 305 0 0 0 0 0.6 0.2 1.3 0.3 09/28/2004 11:10:00 5.4 0.6 6.8 3.4 5.6 0.6 6.8 4.2 0.4 0 0.4 0.4 330 8 326 305 0 0 0 0 0.5 0.1 1 0.3 09/28/2004 11:20:00 4.9 0.5 5.7 3.8 5.1 0.4 6.5 3.8 0.4 0 0.4 0.4 353 8 347 305 0 0 0 0 0.9 0.1 1.5 0.6 09/28/2004 11:30:00 7 2.5 12.6 3.8 7 2.6 13 3.8 0.4 0 0.4 0.4 12 6 0 305 0 0 0 0 1.6 0.2 2.2 1 09/28/2004 11:40:00 10.7 0.7 12.2 8.8 10.7 0.8 12.6 8 0.4 0 0.4 0.4 17 5 18 305 0 0 0 0 1.7 0.1 2.2 1.5 09/28/2004 11:50:00 10.5 0.7 11.8 8.8 10.7 0.8 12.2 8 0.4 0 0.4 0.4 10 4 26 305 0 0 0 0 1.6 0 2.2 1.5 09/28/2004 12:00:00 10.6 1 12.2 7.6 10.6 1 12.2 7.6 0.4 0 0.4 0.4 15 6 24 305 0 0 0 0 1.2 0.1 1.7 1 09/28/2004 12:10:00 10 0.8 11.8 8 10.1 0.8 12.2 8 0.4 0 0.4 0.4 9 5 3 305 0 0 0 0 1 0.1 1.5 0.8 09/28/2004 12:20:00 10.8 0.8 13 9.1 11.1 0.9 13.3 9.1 0.4 0 0.4 0.4 6 5 5 305 0 0 0 0 1.6 0.1 2.2 1.3 09/28/2004 12:30:00 11.3 0.8 13.3 9.1 11.5 0.8 13.7 9.1 0.4 0 0.4 0.4 2 8 17 305 0 0 0 0 1.7 0.1 2.2 1.5 09/28/2004 12:40:00 13 0.7 14.5 11.5 12.9 0.8 14.9 10.3 0.4 0 0.4 0.4 18 3 19 305 0 0 0 0 1.8 0.1 2.2 1.5 09/28/2004 12:50:00 11.8 0.8 13.3 9.5 11.8 1 13.7 9.1 0.4 0 0.4 0.4 14 6 21 305 0 0 0 0 1.6 0 2.2 1.3 09/28/2004 13:00:00 11.1 0.8 13 8.4 11.3 0.8 13.3 8.8 0.4 0 0.4 0.4 18 4 14 305 0 0 0 0 1.2 0.2 2 1 09/28/2004 13:10:00 11.6 0.8 13 9.5 11.8 0.9 13.3 9.5 0.4 0 0.4 0.4 7 5 7 305 0 0 0 0 1.4 0.1 2.2 1 09/28/2004 13:20:00 11.9 0.9 13.7 9.1 11.9 1 13.7 9.1 0.4 0 0.4 0.4 12 4 14 305 0 0 0 0 1.7 0.1 2.2 1.5 09/28/2004 13:30:00 11.7 0.7 13.7 9.5 11.8 0.8 13.3 9.5 0.4 0 0.4 0.4 12 3 13 305 0 0 0 0 2 0 2.5 2 09/28/2004 13:40:00 11.8 0.9 14.5 9.5 11.8 1 14.9 9.1 0.4 0 0.4 0.4 9 4 6 305 0 0 0 0 2.2 0.1 2.7 2 09/28/2004 13:50:00 11.8 0.7 13.3 9.5 11.9 0.8 14.1 9.9 0.4 0 0.4 0.4 8 4 12 305 0 0 0 0 2.3 0.1 2.9 2.2 09/28/2004 14:00:00 11.6 0.8 13.3 9.5 11.7 0.9 13.7 9.1 0.4 0 0.4 0.4 10 4 5 305 0 0 0 0 2.5 0.1 2.9 2.2 09/28/2004 14:10:00 11.3 0.9 13 8.4 11.4 1 13.3 7.6 0.4 0 0.4 0.4 9 4 8 305 0 0 0 0 2.5 0.1 2.9 2.2 09/28/2004 14:20:00 11.3 0.8 14.1 8.4 11.4 0.8 13.7 8.8 0.4 0 0.4 0.4 8 5 11 305 0 0 0 0 2.6 0.1 3.2 2.5 09/28/2004 14:30:00 11.6 0.6 13 9.5 11.7 0.8 13.3 9.5 0.4 0 0.4 0.4 8 5 11 305 0 0 0 0 2.6 0 3.2 2.5 09/28/2004 14:40:00 12 0.8 13.7 9.1 12.1 0.9 14.1 9.5 0.4 0 0.4 0.4 8 4 9 305 0 0 0 0 2.4 0.2 2.9 2.2 09/28/2004 14:50:00 11.8 0.7 13.7 9.5 12 0.8 13.7 9.5 0.4 0 0.4 0.4 7 3 9 305 0 0 0 0 2.3 0.1 2.7 2.2 09/28/2004 15:00:00 12.1 0.7 13.7 9.9 12.2 0.8 13.7 9.9 0.4 0 0.4 0.4 12 4 12 305 0 0 0 0 2.3 0.1 2.7 2.2 09/28/2004 15:10:00 11.6 0.7 13.3 9.1 11.7 0.8 13.3 9.9 0.4 0 0.4 0.4 13 5 16 305 0 0 0 0 2.3 0.2 2.7 2.2 09/28/2004 15:20:00 11.8 0.9 13.7 9.1 11.9 1 14.1 9.1 0.4 0 0.4 0.4 12 4 18 305 0 0 0 0 2.3 0.1 2.7 2.2 09/28/2004 15:30:00 11.4 0.7 13.3 9.1 11.5 0.9 13.7 8.8 0.4 0 0.4 0.4 11 5 8 305 0 0 0 0 2.3 0.2 2.9 2.2 09/28/2004 15:40:00 11.6 0.8 13.7 9.1 11.7 1 13.7 8.8 0.4 0 0.4 0.4 13 4 14 305 0 0 0 0 2.4 0.1 2.9 2.2 09/28/2004 15:50:00 11.7 0.9 13.7 9.1 11.9 1 14.1 8.4 0.4 0 0.4 0.4 14 5 18 305 0 0 0 0 2.4 0.1 2.9 2.2 09/28/2004 16:00:00 11.7 0.9 13.7 9.5 11.7 1 13.7 9.1 0.4 0 0.4 0.4 13 5 15 305 0 0 0 0 2.4 0.1 2.9 2.2 09/28/2004 16:10:00 11.6 0.8 13.3 8.8 11.7 0.8 13.3 8.8 0.4 0 0.4 0.4 14 5 21 305 0 0 0 0 2.5 0.1 2.9 2.2 09/28/2004 16:20:00 11.4 0.9 13.3 8.8 11.4 1 13.7 9.1 0.4 0 0.4 0.4 12 5 12 305 0 0 0 0 2.4 0.1 2.9 2.2 09/28/2004 16:30:00 11.9 0.8 13.7 9.9 12.1 0.8 14.1 9.9 0.4 0 0.4 0.4 13 3 12 305 0 0 0 0 2.3 0.1 2.9 2.2 09/28/2004 16:40:00 12 0.8 14.1 9.5 12.1 0.8 14.5 9.5 0.4 0 0.4 0.4 12 4 8 305 0 0 0 0 2.8 0.1 3.2 2.5 09/28/2004 16:50:00 11.2 0.9 13.3 9.1 11.3 0.9 13.3 9.1 0.4 0 0.4 0.4 12 5 3 305 0 0 0 0 2.7 0.1 3.2 2.5 09/28/2004 17:00:00 11.4 0.8 13 9.1 11.6 0.9 13.3 9.1 0.4 0 0.4 0.4 13 5 13 305 0 0 0 0 2.8 0.1 3.4 2.7 09/28/2004 17:10:00 11.4 0.7 13 9.1 11.4 0.7 13.3 9.5 0.4 0 0.4 0.4 14 4 10 305 0 0 0 0 2.8 0.1 3.4 2.7 09/28/2004 17:20:00 11.8 0.6 13.3 10.3 12 0.6 13.7 10.3 0.4 0 0.4 0.4 13 3 16 305 0 0 0 0 2.8 0.1 3.4 2.7 09/28/2004 17:30:00 11.4 0.6 13 9.5 11.6 0.7 13.7 9.5 0.4 0 0.4 0.4 12 4 14 305 0 0 0 0 2.8 0.1 3.2 2.7 09/28/2004 17:40:00 11 0.7 13 9.1 11.1 0.9 13 8.8 0.4 0 0.4 0.4 12 5 13 305 0 0 0 0 2.8 0.1 3.4 2.7 09/28/2004 17:50:00 10.9 0.7 13 8.8 11 0.8 13.3 8.8 0.4 0 0.4 0.4 16 5 12 305 0 0 0 0 2.7 0 3.2 2.5 09/28/2004 18:00:00 10.9 0.8 12.6 8.8 11.1 0.8 12.6 9.1 0.4 0 0.4 0.4 13 4 12 305 0 0 0 0 2.6 0 3.2 2.5 09/28/2004 18:10:00 11.2 0.9 14.1 8.8 11.2 0.9 13.7 8.8 0.4 0 0.4 0.4 15 4 5 305 0 0 0 0 2.6 0 3.2 2.5 09/28/2004 18:20:00 10.7 0.8 13.3 8.8 10.8 0.9 13.3 8.4 0.4 0 0.4 0.4 15 5 12 305 0 0 0 0 2.7 0 3.2 2.5 09/28/2004 18:30:00 10.3 0.7 12.2 8 10.4 0.7 12.2 8.4 0.4 0 0.4 0.4 15 6 15 305 0 0 0 0 2.5 0.1 3.2 2.2 09/28/2004 18:40:00 10.3 0.8 12.6 8.4 10.4 0.8 12.6 8.4 0.4 0 0.4 0.4 18 4 20 305 0 0 0 0 2.3 0.1 2.9 2.2 09/28/2004 18:50:00 10.1 0.7 11.8 8 10.3 0.7 11.8 7.6 0.4 0 0.4 0.4 16 4 12 305 0 0 0 0 2.3 0.1 2.7 2.2 09/28/2004 19:00:00 10.7 0.8 12.6 8 10.9 0.9 12.6 8.4 0.4 0 0.4 0.4 11 4 10 305 0 0 0 0 2.2 0.1 2.7 2.2 09/28/2004 19:10:00 10.4 0.9 13 8.4 10.6 1 13.7 8.4 0.4 0 0.4 0.4 10 7 8 305 0 0 0 0 2.3 0.2 2.7 2 09/28/2004 19:20:00 10.3 0.7 11.8 8 10.5 0.8 12.2 8 0.4 0 0.4 0.4 8 5 10 305 0 0 0 0 2.2 0.1 2.7 2 09/28/2004 19:30:00 10.3 0.7 11.8 8 10.4 0.7 12.2 8 0.4 0 0.4 0.4 7 4 6 305 0 0 0 0 2 0.1 2.5 2 09/28/2004 19:40:00 10.3 0.8 12.6 8 10.4 0.8 13 7.6 0.4 0 0.4 0.4 6 5 0 305 0 0 0 0 2 0 2.5 2 09/28/2004 19:50:00 10.3 0.7 11.8 8.8 10.4 0.8 12.2 8 0.4 0 0.4 0.4 8 4 3 305 0 0 0 0 2 0.1 2.5 2 09/28/2004 20:00:00 10 0.8 11.8 7.6 10.2 0.8 11.8 7.6 0.4 0 0.4 0.4 5 5 3 305 0 0 0 0 2 0 2.5 2 09/28/2004 20:10:00 9.9 0.6 11.5 8.4 10.1 0.7 11.8 8.4 0.4 0 0.4 0.4 7 4 6 305 0 0 0 0 2 0 2.5 2 09/28/2004 20:20:00 9.8 0.8 11.8 8 10 0.8 11.8 8 0.4 0 0.4 0.4 10 5 5 305 0 0 0 0 2.1 0.1 2.7 2 09/28/2004 20:30:00 9.8 0.6 11.5 8.4 9.9 0.7 11.5 8.4 0.4 0 0.4 0.4 12 4 3 305 0 0 0 0 2.1 0 2.7 2 09/28/2004 20:40:00 9 0.9 11.5 7.2 9.2 0.9 11.8 6.8 0.4 0 0.4 0.4 10 6 11 305 0 0 0 0 2.2 0 2.7 2 09/28/2004 20:50:00 9.2 1.2 11.8 6.5 9.4 1.2 11.5 6.8 0.4 0 0.4 0.4 22 5 22 305 0 0 0 0 2 0.1 2.5 1.7 09/28/2004 21:00:00 9.6 0.9 11.5 7.6 9.7 0.9 11.5 6.8 0.4 0 0.4 0.4 19 6 21 305 0 0 0 0 2.2 0.1 2.7 2.2 09/28/2004 21:10:00 10.4 1 12.6 7.6 10.5 1.1 13 7.6 0.4 0 0.4 0.4 14 5 0 305 0 0 0 0 2 0.1 2.5 1.7 09/28/2004 21:20:00 11.2 0.8 13.3 9.1 11.3 0.8 13.3 9.1 0.4 0 0.4 0.4 26 13 40 305 0 0 0 0 1.8 0.1 2.5 1.5 09/28/2004 21:30:00 10.3 0.7 12.2 8.4 10.2 0.8 12.6 8 0.4 0 0.4 0.4 36 9 36 305 0 0 0 0 1.7 0.1 2.5 1.5 09/28/2004 21:40:00 9.8 0.8 11.8 7.6 9.8 0.8 11.8 7.2 0.4 0 0.4 0.4 24 5 32 305 0 0 0 0 2 0 2.5 2 09/28/2004 21:50:00 9.6 0.6 11.1 8 9.6 0.6 11.5 7.6 0.4 0 0.4 0.4 22 5 17 305 0 0 0 0 2.1 0.1 2.7 2 09/28/2004 22:00:00 9.2 0.7 11.1 7.2 9.2 0.8 11.1 7.6 0.4 0 0.4 0.4 22 5 22 305 0 0 0 0 2.1 0 2.7 2 09/28/2004 22:10:00 9.3 0.7 10.7 8 9.4 0.7 10.7 7.6 0.4 0 0.4 0.4 22 4 19 305 0 0 0 0 2.2 0.1 2.7 2 09/28/2004 22:20:00 9.7 0.6 11.5 8 9.7 0.7 11.8 7.6 0.4 0 0.4 0.4 21 4 24 305 0 0 0 0 2.3 0.1 2.7 2.2 09/28/2004 22:30:00 10.3 0.8 12.6 7.6 10.3 0.9 13 7.6 0.4 0 0.4 0.4 20 5 21 305 0 0 0 0 2.2 0.1 2.7 2.2 09/28/2004 22:40:00 10.5 0.8 13 8.4 10.6 0.9 13.3 8.4 0.4 0 0.4 0.4 21 5 21 305 0 0 0 0 2.2 0.1 2.7 2 09/28/2004 22:50:00 10.2 0.6 11.5 8.4 10.2 0.7 11.8 8.4 0.4 0 0.4 0.4 20 5 21 305 0 0 0 0 2.2 0 2.7 2.2 09/28/2004 23:00:00 9.8 0.6 11.1 7.6 9.8 0.6 11.5 7.6 0.4 0 0.4 0.4 24 5 21 305 0 0 0 0 2.2 0.1 2.7 2.2 09/28/2004 23:10:00 10.4 0.7 12.6 8.8 10.4 0.8 12.6 8.4 0.4 0 0.4 0.4 30 5 32 305 0 0 0 0 2.2 0 2.7 2 09/28/2004 23:20:00 10.1 0.6 11.5 8.4 10.1 0.6 11.8 8.4 0.4 0 0.4 0.4 31 5 30 305 0 0 0 0 2.2 0 2.7 2 09/28/2004 23:30:00 9.8 0.6 11.5 8 9.8 0.7 11.8 8 0.4 0 0.4 0.4 26 5 33 305 0 0 0 0 2.2 0.1 2.7 2 09/28/2004 23:40:00 10.2 0.6 11.8 8.4 10.3 0.8 11.8 7.6 0.4 0 0.4 0.4 27 6 27 305 0 0 0 0 2.1 0.1 2.5 2 09/28/2004 23:50:00 10.2 0.7 11.8 8 10.2 0.8 12.2 7.6 0.4 0 0.4 0.4 27 5 29 305 0 0 0 0 2.2 0.1 2.5 2 09/29/2004 00:00:00 10.6 0.7 12.2 8.8 10.5 0.7 12.2 8 0.4 0 0.4 0.4 29 5 36 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 00:10:00 10.4 0.8 12.2 8.4 10.5 0.8 12.2 8.4 0.4 0 0.4 0.4 24 3 29 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 00:20:00 10 0.7 11.8 7.6 10.1 0.8 12.2 7.2 0.4 0 0.4 0.4 20 4 22 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 00:30:00 10.2 0.7 11.8 8.4 10.2 0.7 11.8 8.4 0.4 0 0.4 0.4 23 5 19 305 0 0 0 0 2.2 0 2.5 2 09/29/2004 00:40:00 10 0.8 12.2 8.4 10 0.9 12.6 7.6 0.4 0 0.4 0.4 24 4 25 305 0 0 0 0 2.2 0 2.5 2 09/29/2004 00:50:00 10.1 0.7 12.2 8.4 10.1 0.8 12.2 8.4 0.4 0 0.4 0.4 25 5 26 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 01:00:00 10.3 0.6 11.8 8.4 10.3 0.6 12.2 8.4 0.4 0 0.4 0.4 22 4 27 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 01:10:00 10.4 0.6 12.2 8.8 10.5 0.6 12.2 8.8 0.4 0 0.4 0.4 18 4 18 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 01:20:00 10.4 0.7 12.2 8 10.4 0.8 12.2 8.4 0.4 0 0.4 0.4 16 4 22 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 01:30:00 10 0.6 11.5 8 10.1 0.7 11.5 8 0.4 0 0.4 0.4 15 4 18 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 01:40:00 10.1 0.6 11.5 8 10.2 0.6 11.8 8.4 0.4 0 0.4 0.4 15 4 22 305 0 0 0 0 2 0 2.5 2 09/29/2004 01:50:00 9.9 0.7 11.8 8 9.9 0.8 12.2 8 0.4 0 0.4 0.4 12 5 10 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 02:00:00 10.5 0.7 11.8 8.4 10.5 0.8 12.2 7.6 0.4 0 0.4 0.4 14 4 9 305 0 0 0 0 2 0 2.5 2 09/29/2004 02:10:00 10.1 0.5 11.1 8 10.2 0.6 11.5 8 0.4 0 0.4 0.4 14 4 17 305 0 0 0 0 1.9 0 2.5 2 09/29/2004 02:20:00 10.3 0.6 12.2 8.8 10.4 0.7 12.2 8.4 0.4 0 0.4 0.4 14 5 18 305 0 0 0 0 1.9 0.1 2.5 2 09/29/2004 02:30:00 10.2 0.5 11.5 8.8 10.3 0.6 11.8 8.4 0.4 0 0.4 0.4 10 4 8 305 0 0 0 0 1.9 0.1 2.5 1.7 09/29/2004 02:40:00 9.7 0.6 11.1 7.6 9.9 0.7 11.8 8 0.4 0 0.4 0.4 11 4 12 305 0 0 0 0 1.9 0.1 2.2 1.7 09/29/2004 02:50:00 10.1 0.9 13 7.2 10.2 1 12.6 7.6 0.4 0 0.4 0.4 7 5 6 305 0 0 0 0 1.9 0.1 2.5 1.7 09/29/2004 03:00:00 10.5 0.8 13.3 8.4 10.6 0.8 13 8.4 0.4 0 0.4 0.4 11 5 5 305 0 0 0 0 1.9 0 2.5 1.7 09/29/2004 03:10:00 10.9 0.8 12.6 8.4 11.1 0.8 13 8.4 0.4 0 0.4 0.4 7 4 9 305 0 0 0 0 1.9 0.1 2.5 1.5 09/29/2004 03:20:00 10.6 0.6 12.2 8.4 10.7 0.7 12.2 8.8 0.4 0 0.4 0.4 8 4 4 305 0 0 0 0 1.9 0 2.5 1.7 09/29/2004 03:30:00 10.4 0.8 12.2 8.4 10.5 0.9 12.2 8 0.4 0 0.4 0.4 12 5 15 305 0 0 0 0 2 0 2.5 2 09/29/2004 03:40:00 10.3 0.7 11.8 8 10.5 0.7 12.2 8.8 0.4 0 0.4 0.4 9 5 10 305 0 0 0 0 2 0 2.5 1.7 09/29/2004 03:50:00 10.4 0.8 12.6 8 10.5 0.9 12.6 8 0.4 0 0.4 0.4 12 4 14 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 04:00:00 9.9 0.7 11.5 7.6 10 0.8 12.2 8 0.4 0 0.4 0.4 9 4 8 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 04:10:00 10.3 0.8 11.8 8.4 10.4 0.8 12.6 8 0.4 0 0.4 0.4 10 6 8 305 0 0 0 0 2.1 0 2.5 2 09/29/2004 04:20:00 10.9 0.7 13 9.1 11 0.8 13 8.8 0.4 0 0.4 0.4 5 5 7 305 0 0 0 0 2.2 0 2.7 2 09/29/2004 04:30:00 11.6 0.7 13.7 9.5 11.8 0.9 14.5 9.1 0.4 0 0.4 0.4 6 5 11 305 0 0 0 0 2.2 0 2.5 2 09/29/2004 04:40:00 11.6 0.8 13.7 9.9 11.9 0.8 13.7 9.5 0.4 0 0.4 0.4 2 6 5 305 0 0 0 0 2 0 2.5 1.7 09/29/2004 04:50:00 11.3 0.9 13.3 8.8 11.5 1 13.7 9.1 0.4 0 0.4 0.4 5 4 3 305 0 0 0 0 2 0 2.5 2 09/29/2004 05:00:00 11.3 0.7 13 9.1 11.6 0.8 13.3 9.5 0.4 0 0.4 0.4 2 5 357 305 0 0 0 0 2 0 2.5 2 09/29/2004 05:10:00 10.6 0.8 12.6 8.4 10.8 0.8 12.6 8.4 0.4 0 0.4 0.4 4 6 5 305 0 0 0 0 2.1 0.1 2.5 2 09/29/2004 05:20:00 12.2 1.7 14.9 8.4 12.3 1.7 15.3 8.4 0.4 0 0.4 0.4 17 4 18 305 0 0 0 0 1.5 0.5 2.7 0.6 09/29/2004 05:30:00 10.1 1.5 13 7.2 10.4 1.5 13.3 7.2 0.4 0 0.4 0.4 8 6 1 305 0 0 0 0 1.3 0.3 2.2 0.8 09/29/2004 05:40:00 12.3 1.1 14.9 9.9 12.5 1.2 15.3 9.9 0.4 0 0.4 0.4 4 5 0 305 0 0 0 0 1.6 0.1 2.2 1.3 09/29/2004 05:50:00 10.3 1.1 12.6 7.6 10.4 1.2 13.3 7.6 0.4 0 0.4 0.4 9 5 3 305 0 0 0 0 1.6 0 2 1.5 09/29/2004 06:00:00 11.4 0.9 13 8.8 11.5 0.9 13.3 9.1 0.4 0 0.4 0.4 16 4 11 305 0 0 0 0 1.9 0.1 2.5 1.5 09/29/2004 06:10:00 11.3 0.9 13.7 8.8 11.4 1 13.7 9.1 0.4 0 0.4 0.4 13 3 10 305 0 0 0 0 2 0 2.5 2 09/29/2004 06:20:00 11.4 1.1 13.7 8.8 11.5 1.2 13.7 9.1 0.4 0 0.4 0.4 18 5 15 305 0 0 0 0 1.7 0.1 2.2 1.5 09/29/2004 06:30:00 10.3 0.8 12.2 8 10.4 0.9 12.2 8 0.4 0 0.4 0.4 17 5 22 305 0 0 0 0 1.8 0.1 2.5 1.5 09/29/2004 06:40:00 10.7 1 13 7.6 10.8 1 13 7.6 0.4 0 0.4 0.4 10 5 11 305 0 0 0 0 1.9 0 2.5 1.7 09/29/2004 06:50:00 11.1 0.8 13.7 9.1 11.3 0.8 13.3 9.1 0.4 0 0.4 0.4 12 5 17 305 0 0 0 0 1.9 0.1 2.5 1.7 09/29/2004 07:00:00 10.9 1.1 13 8.8 11 1.2 13.3 7.6 0.4 0 0.4 0.4 15 4 13 305 0 0 0 0 1.9 0.1 2.5 1.5 09/29/2004 07:10:00 9.2 1.4 12.6 6.5 9.3 1.4 12.6 6.5 0.4 0 0.4 0.4 11 6 19 305 0 0 0 0 1.3 0.2 2 1 09/29/2004 07:20:00 10.3 0.6 11.8 8.8 10.4 0.7 12.2 8.4 0.4 0 0.4 0.4 26 6 18 305 0 0 0 0 1.9 0.1 2.5 1.5 09/29/2004 07:30:00 10.5 0.8 12.6 8.4 10.5 0.9 12.6 8.8 0.4 0 0.4 0.4 27 5 21 305 0 0 0 0 2 0 2.5 2 09/29/2004 07:40:00 10.8 0.9 13 8.4 10.7 1 13.3 8.4 0.4 0 0.4 0.4 26 5 22 305 0 0 0 0 2 0 2.5 2 09/29/2004 07:50:00 10.4 0.9 12.2 8 10.4 1 12.2 8 0.4 0 0.4 0.4 23 4 25 305 0 0 0 0 2 0 2.5 2 09/29/2004 08:00:00 11.2 0.6 12.6 8.8 11.3 0.7 13 8.8 0.4 0 0.4 0.4 22 4 23 305 0 0 0 0 1.9 0 2.5 1.7 09/29/2004 08:10:00 10.6 0.7 12.2 8.8 10.6 0.7 11.8 8.8 0.4 0 0.4 0.4 13 5 18 305 0 0 0 0 1.8 0 2.5 1.7 09/29/2004 08:20:00 10.5 0.7 11.8 8.8 10.6 0.7 12.2 8.8 0.4 0 0.4 0.4 18 7 12 305 0 0 0 0 1.9 0 2.5 1.7 09/29/2004 08:30:00 10.6 0.7 12.2 8.4 10.6 0.9 12.6 8.4 0.4 0 0.4 0.4 20 8 2 305 0 0 0 0 1.9 0 2.5 2 09/29/2004 08:40:00 10.3 0.9 12.2 8 10.4 0.9 12.2 8.4 0.4 0 0.4 0.4 24 4 27 305 0 0 0 0 1.9 0 2.5 1.7 09/29/2004 08:50:00 10 0.7 11.8 8.4 10.1 0.8 11.8 8 0.4 0 0.4 0.4 25 5 21 305 0 0 0 0 1.9 0.1 2.2 1.7 09/29/2004 09:00:00 10.4 0.7 12.2 8.4 10.4 0.8 12.2 8 0.4 0 0.4 0.4 26 5 25 305 0 0 0 0 1.9 0 2.5 1.7 09/29/2004 09:10:00 10.1 0.6 11.5 8.4 10.1 0.7 11.8 8 0.4 0 0.4 0.4 25 5 12 305 0 0 0 0 1.9 0.1 2.5 1.7 09/29/2004 09:20:00 10 0.6 11.8 8 10 0.7 11.8 8 0.4 0 0.4 0.4 33 4 34 305 0 0 0 0 1.9 0.1 2.2 1.5 09/29/2004 09:30:00 10.5 0.6 11.8 8 10.5 0.6 12.2 8 0.4 0 0.4 0.4 30 4 30 305 0 0 0 0 1.7 0.1 2.2 1.5 09/29/2004 09:40:00 10.1 0.7 11.5 8 10.1 0.7 11.5 7.6 0.4 0 0.4 0.4 30 4 32 305 0 0 0 0 1.7 0.1 2.2 1.5 09/29/2004 09:50:00 9.6 0.6 11.1 8 9.7 0.6 11.1 7.6 0.4 0 0.4 0.4 29 4 31 305 0 0 0 0 1.7 0.1 2.2 1.5 09/29/2004 10:00:00 9.2 1.1 11.5 6.5 9.2 1.1 11.8 6.5 0.4 0 0.4 0.4 26 4 22 305 0 0 0 0 1.9 0 2.5 1.5 09/29/2004 10:10:00 10.6 1 13 7.6 10.5 1.1 13.3 8 0.4 0 0.4 0.4 43 8 42 305 0 0 0 0 1.8 0.2 2.5 1.5 09/29/2004 10:20:00 9.3 1.1 12.6 6.5 9.3 1.2 13 6.8 0.4 0 0.4 0.4 34 12 13 305 0 0 0 0 1.7 0.1 2.2 1.5 09/29/2004 10:30:00 10.1 0.6 11.5 8.4 10.2 0.7 11.8 8.4 0.4 0 0.4 0.4 13 4 10 305 0 0 0 0 1.5 0.2 2.2 1.3 09/29/2004 10:40:00 10.2 0.7 11.8 8.4 10.3 0.8 12.2 8 0.4 0 0.4 0.4 19 7 14 305 0 0 0 0 1.9 0.3 2.7 1.3 09/29/2004 10:50:00 10.8 1 13 8 10.8 1.1 13.3 8 0.4 0 0.4 0.4 20 11 13 305 0 0 0 0 2.2 0.2 2.9 2 09/29/2004 11:00:00 11.7 0.8 14.1 9.5 11.8 1 14.5 9.1 0.4 0 0.4 0.4 8 5 2 305 0 0 0 0 1.8 0.1 2.2 1.5 09/29/2004 11:10:00 11.6 0.8 13.3 9.5 11.8 0.8 13.7 9.1 0.4 0 0.4 0.4 7 3 6 305 0 0 0 0 1.5 0 2.2 1.3 09/29/2004 11:20:00 10.8 0.7 12.6 8.8 10.9 0.8 12.6 8.4 0.4 0 0.4 0.4 17 5 13 305 0 0 0 0 1 0.3 2 0.6 09/29/2004 11:30:00 10 1.1 12.6 7.6 10 1.1 13 6.8 0.4 0 0.4 0.4 23 6 23 305 0 0 0 0 0.8 0.3 1.7 0.3 09/29/2004 11:40:00 11 0.8 12.6 8.8 11 0.8 13 9.1 0.4 0 0.4 0.4 20 7 18 305 0 0 0 0 1.2 0.1 2 1 09/29/2004 11:50:00 11.1 0.6 12.6 9.1 11.2 0.7 12.6 9.1 0.4 0 0.4 0.4 16 3 18 305 0 0 0 0 1.6 0 2.2 1.3 09/29/2004 12:00:00 10.6 0.8 12.6 8 10.6 1 13 8 0.4 0 0.4 0.4 13 6 19 305 0 0 0 0 1.7 0.1 2.2 1.5 09/29/2004 12:10:00 10.6 0.7 12.2 8 10.7 0.7 12.2 8.4 0.4 0 0.4 0.4 11 3 9 305 0 0 0 0 1.8 0.1 2.2 1.5 09/29/2004 12:20:00 10.5 0.8 12.6 7.2 10.6 0.9 13.3 7.6 0.4 0 0.4 0.4 11 4 7 305 0 0 0 0 1.7 0.1 2.2 1.5 09/29/2004 12:30:00 9.9 0.7 11.8 8 10 0.8 13 8 0.4 0 0.4 0.4 11 5 19 305 0 0 0 0 1.8 0.1 2.5 1.5 09/29/2004 12:40:00 10.1 0.7 11.8 8 10.2 0.8 11.8 8 0.4 0 0.4 0.4 10 4 14 305 0 0 0 0 1.7 0.1 2.2 1.5 09/29/2004 12:50:00 9.8 0.7 11.5 8 9.9 0.7 11.5 7.6 0.4 0 0.4 0.4 13 4 12 305 0 0 0 0 1.8 0.1 2.5 1.5 09/29/2004 13:00:00 9.6 0.6 11.1 8 9.7 0.7 11.1 7.6 0.4 0 0.4 0.4 12 4 14 305 0 0 0 0 1.6 0.1 2.2 1.5 09/29/2004 13:10:00 9.1 0.6 11.1 7.2 9.2 0.6 11.1 7.2 0.4 0 0.4 0.4 11 3 14 305 0 0 0 0 1.9 0.2 2.5 1.5 09/29/2004 13:20:00 9 0.5 10.3 7.2 9.1 0.6 10.7 7.6 0.4 0 0.4 0.4 10 4 12 305 0 0 0 0 2.1 0 2.7 2 09/29/2004 13:30:00 9 0.6 10.3 7.2 9.2 0.6 10.7 7.2 0.4 0 0.4 0.4 9 5 2 305 0 0 0 0 2 0.2 2.7 1.5 09/29/2004 13:40:00 8.6 0.5 9.9 7.2 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 6 5 1 305 0 0 0 0 2 0.2 2.7 1.7 09/29/2004 13:50:00 9.4 0.5 10.7 8 9.6 0.6 11.1 7.6 0.4 0 0.4 0.4 358 4 358 305 0 0 0 0 1.9 0.2 2.5 1.5 09/29/2004 14:00:00 8.8 0.7 10.7 6.8 9 0.7 11.1 6.8 0.4 0 0.4 0.4 4 5 5 305 0 0 0 0 2 0.2 2.7 1.5 09/29/2004 14:10:00 8.9 0.8 10.3 6.8 9.1 0.8 10.7 6.5 0.4 0 0.4 0.4 1 4 7 305 0 0 0 0 2.1 0.1 2.7 1.7 09/29/2004 14:20:00 8.8 0.5 10.3 7.2 9.1 0.6 10.7 7.2 0.4 0 0.4 0.4 1 4 2 305 0 0 0 0 1.8 0.2 2.5 1.5 09/29/2004 14:30:00 8.7 0.7 11.1 6.8 8.8 0.8 10.7 6.1 0.4 0 0.4 0.4 3 5 356 305 0 0 0 0 2 0.3 2.9 1.5 09/29/2004 14:40:00 8.6 0.6 10.3 6.8 8.8 0.6 10.7 6.8 0.4 0 0.4 0.4 2 5 356 305 0 0 0 0 2 0.2 2.7 1.7 09/29/2004 14:50:00 9 0.6 10.3 7.2 9.2 0.6 10.7 7.2 0.4 0 0.4 0.4 2 5 2 305 0 0 0 0 1.9 0.2 2.5 1.5 09/29/2004 15:00:00 8.9 0.7 11.1 7.2 9 0.8 11.5 7.2 0.4 0 0.4 0.4 3 5 7 305 0 0 0 0 2 0.1 2.5 1.5 09/29/2004 15:10:00 8.6 0.6 10.3 6.8 8.9 0.6 10.7 6.8 0.4 0 0.4 0.4 0 5 6 305 0 0 0 0 1.9 0.1 2.5 1.5 09/29/2004 15:20:00 8.9 0.6 10.3 7.2 9.2 0.6 10.7 7.2 0.4 0 0.4 0.4 358 4 0 305 0 0 0 0 1.9 0 2.5 1.7 09/29/2004 15:30:00 8.8 0.6 9.9 7.2 9.1 0.6 10.7 7.2 0.4 0 0.4 0.4 1 5 5 305 0 0 0 0 2 0 2.7 2 09/29/2004 15:40:00 9 0.6 10.7 7.6 9.2 0.7 10.7 6.8 0.4 0 0.4 0.4 3 4 7 305 0 0 0 0 2.2 0.1 2.7 2 09/29/2004 15:50:00 9 0.6 10.3 6.8 9.3 0.6 10.7 6.8 0.4 0 0.4 0.4 4 4 6 305 0 0 0 0 2.2 0 2.7 2 09/29/2004 16:00:00 9 0.6 10.3 7.2 9.2 0.6 10.7 7.2 0.4 0 0.4 0.4 2 4 354 305 0 0 0 0 2.3 0.2 2.9 2 09/29/2004 16:10:00 8.7 0.5 9.9 6.8 8.9 0.6 10.3 6.8 0.4 0 0.4 0.4 357 4 357 305 0 0 0 0 2.3 0.1 2.9 2.2 09/29/2004 16:20:00 8.8 0.5 9.9 7.2 9.1 0.5 9.9 7.6 0.4 0 0.4 0.4 358 5 358 305 0 0 0 0 2.3 0.1 2.7 2.2 09/29/2004 16:30:00 8.7 0.7 10.3 6.5 9 0.7 10.7 6.8 0.4 0 0.4 0.4 357 4 352 305 0 0 0 0 2.2 0.1 2.7 2 09/29/2004 16:40:00 8.7 0.5 9.9 7.2 8.9 0.7 10.3 6.8 0.4 0 0.4 0.4 355 4 1 305 0 0 0 0 2.2 0.1 2.7 2 09/29/2004 16:50:00 8.8 0.6 10.3 6.8 9 0.6 10.7 7.2 0.4 0 0.4 0.4 357 5 352 305 0 0 0 0 2 0.1 2.7 1.7 09/29/2004 17:00:00 8.6 0.5 9.9 6.8 8.8 0.5 9.9 7.2 0.4 0 0.4 0.4 349 5 352 305 0 0 0 0 2.2 0 2.7 2 09/29/2004 17:10:00 7.9 0.5 9.1 6.1 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 350 5 342 305 0 0 0 0 2.2 0 2.7 2 09/29/2004 17:20:00 8 0.5 9.5 6.5 8.2 0.6 9.9 6.1 0.4 0 0.4 0.4 349 6 353 305 0 0 0 0 2.2 0.1 2.7 2 09/29/2004 17:30:00 7.5 0.6 9.1 6.1 7.7 0.7 9.5 5.7 0.4 0 0.4 0.4 350 5 352 305 0 0 0 0 2 0.2 2.7 1.7 09/29/2004 17:40:00 7.5 0.6 9.1 5.3 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 346 5 350 305 0 0 0 0 2.1 0.1 2.5 2 09/29/2004 17:50:00 7.8 0.5 9.1 5.7 8 0.6 9.5 6.1 0.4 0 0.4 0.4 342 5 341 305 0 0 0 0 2.2 0.1 2.5 2 09/29/2004 18:00:00 7.6 0.5 9.1 6.5 7.8 0.5 9.1 6.1 0.4 0 0.4 0.4 338 4 341 305 0 0 0 0 2 0.1 2.5 2 09/29/2004 18:10:00 7.4 0.6 9.1 5.7 7.6 0.7 9.9 5.7 0.4 0 0.4 0.4 338 4 333 305 0 0 0 0 2 0 2.5 2 09/29/2004 18:20:00 7.2 0.7 9.1 4.9 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 340 5 337 305 0 0 0 0 2 0 2.5 2 09/29/2004 18:30:00 7.4 0.6 9.1 5.7 7.6 0.7 9.1 5.7 0.4 0 0.4 0.4 339 5 336 305 0 0 0 0 2.1 0.1 2.5 2 09/29/2004 18:40:00 7.5 0.6 9.1 5.7 7.7 0.7 9.5 6.1 0.4 0 0.4 0.4 336 7 334 305 0 0 0 0 2 0 2.5 2 09/29/2004 18:50:00 6.7 0.6 8 4.9 7 0.7 8.4 4.9 0.4 0 0.4 0.4 341 7 337 305 0 0 0 0 1.9 0.2 2.5 1.5 09/29/2004 19:00:00 7 0.6 8.4 5.3 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 350 4 346 305 0 0 0 0 1.6 0.1 2.2 1.5 09/29/2004 19:10:00 6.9 0.6 8 5.3 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 348 3 347 305 0 0 0 0 1.4 0 2 1.3 09/29/2004 19:20:00 6.8 0.7 8.4 4.9 7.1 0.7 8.4 5.3 0.4 0 0.4 0.4 341 6 340 305 0 0 0 0 1.4 0 2 1.3 09/29/2004 19:30:00 6.7 0.5 8.4 5.3 6.9 0.6 8.8 4.9 0.4 0 0.4 0.4 341 5 346 305 0 0 0 0 1.2 0.1 1.7 1 09/29/2004 19:40:00 6.2 0.6 8.8 4.6 6.4 0.6 8.4 5.3 0.4 0 0.4 0.4 345 6 349 305 0 0 0 0 1.1 0.1 1.5 1 09/29/2004 19:50:00 6.2 0.4 7.6 4.9 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 341 6 344 305 0 0 0 0 1.1 0 1.5 1 09/29/2004 20:00:00 5.9 0.6 7.2 4.6 6.2 0.6 7.2 4.6 0.4 0 0.4 0.4 344 5 341 305 0 0 0 0 1 0 1.5 1 09/29/2004 20:10:00 5.9 0.5 7.6 4.2 6.2 0.6 8 3.8 0.4 0 0.4 0.4 344 6 338 305 0 0 0 0 1.1 0 1.5 1 09/29/2004 20:20:00 5.6 0.5 6.8 3.8 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 343 5 340 305 0 0 0 0 1.1 0 1.5 1 09/29/2004 20:30:00 5.5 0.5 6.8 4.2 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 335 6 327 305 0 0 0 0 1.1 0.1 1.5 1 09/29/2004 20:40:00 5.1 0.7 6.8 3.4 5.3 0.7 6.8 3.8 0.4 0 0.4 0.4 338 5 323 305 0 0 0 0 1 0 1.5 0.8 09/29/2004 20:50:00 5.1 0.6 6.8 3.8 5.4 0.6 7.2 3.8 0.4 0 0.4 0.4 335 5 329 305 0 0 0 0 1 0 1.5 0.8 09/29/2004 21:00:00 5.5 0.6 6.8 4.2 5.6 0.6 7.2 4.2 0.4 0 0.4 0.4 326 7 325 305 0 0 0 0 1 0 1.5 0.8 09/29/2004 21:10:00 5.6 0.5 6.8 4.2 5.7 0.5 6.5 4.2 0.4 0 0.4 0.4 320 6 316 305 0 0 0 0 0.8 0.1 1.3 0.6 09/29/2004 21:20:00 5.5 0.5 6.8 4.6 5.5 0.5 6.8 4.6 0.4 0 0.4 0.4 314 5 306 305 0 0 0 0 0.7 0.1 1.3 0.6 09/29/2004 21:30:00 5.5 0.6 6.8 3.8 5.5 0.6 6.8 4.2 0.4 0 0.4 0.4 316 6 321 305 0 0 0 0 0.6 0.1 1.3 0.6 09/29/2004 21:40:00 5.4 0.5 6.5 4.2 5.5 0.5 6.8 3.8 0.4 0 0.4 0.4 319 6 317 305 0 0 0 0 0.7 0.1 1.3 0.6 09/29/2004 21:50:00 4.7 0.5 5.7 3.8 4.8 0.6 6.1 3.8 0.4 0 0.4 0.4 320 6 319 305 0 0 0 0 0.6 0.1 1.3 0.6 09/29/2004 22:00:00 4.8 0.5 5.7 3.4 4.9 0.5 6.1 3.4 0.4 0 0.4 0.4 328 7 320 305 0 0 0 0 0.6 0.1 1 0.6 09/29/2004 22:10:00 4.5 0.4 5.3 3.4 4.7 0.4 5.7 3.4 0.4 0 0.4 0.4 331 4 333 305 0 0 0 0 0.7 0.1 1.3 0.6 09/29/2004 22:20:00 4.1 0.4 5.3 3 4.4 0.4 5.7 3.4 0.4 0 0.4 0.4 331 4 327 305 0 0 0 0 0.7 0.1 1.3 0.6 09/29/2004 22:30:00 4.3 0.6 5.7 2.6 4.5 0.6 6.1 3.4 0.4 0 0.4 0.4 330 7 327 305 0 0 0 0 0.7 0.1 1.3 0.6 09/29/2004 22:40:00 4.4 0.5 5.7 3.4 4.6 0.5 6.1 3.8 0.4 0 0.4 0.4 330 8 323 305 0 0 0 0 0.7 0.1 1.3 0.6 09/29/2004 22:50:00 4.3 0.4 5.7 3.4 4.5 0.4 5.7 3.4 0.4 0 0.4 0.4 326 7 326 305 0 0 0 0 0.6 0.1 1 0.6 09/29/2004 23:00:00 3.9 0.6 5.3 2.6 4.1 0.6 5.7 2.6 0.4 0 0.4 0.4 327 8 321 305 0 0 0 0 0.7 0.1 1.3 0.6 09/29/2004 23:10:00 4.2 0.7 6.1 2.6 4.2 0.7 6.1 2.6 0.4 0 0.4 0.4 317 7 306 305 0 0 0 0 0.6 0 1 0.6 09/29/2004 23:20:00 3.8 0.6 4.9 2.3 4 0.5 5.3 2.6 0.4 0 0.4 0.4 314 6 323 305 0 0 0 0 0.6 0.1 1 0.6 09/29/2004 23:30:00 4.2 0.5 5.7 3 4.3 0.5 5.7 3 0.4 0 0.4 0.4 315 6 310 305 0 0 0 0 0.5 0 1 0.6 09/29/2004 23:40:00 3.9 0.6 5.3 2.6 4 0.5 5.3 3 0.4 0 0.4 0.4 315 7 316 305 0 0 0 0 0.5 0 1 0.3 09/29/2004 23:50:00 3.2 0.6 4.6 1.9 3.4 0.6 4.9 2.3 0.4 0 0.4 0.4 316 9 316 305 0 0 0 0 0.6 0.1 1 0.6 09/30/2004 00:00:00 3 0.4 4.2 2.3 3.2 0.4 4.2 2.3 0.4 0 0.4 0.4 322 10 322 305 0 0 0 0 0.5 0 1 0.3 09/30/2004 00:10:00 3.2 0.6 4.9 2.3 3.3 0.6 4.9 2.3 0.4 0 0.4 0.4 315 7 308 305 0 0 0 0 0.3 0.1 0.8 0.1 09/30/2004 00:20:00 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.6 0.4 0 0.4 0.4 311 5 305 305 0 0 0 0 0.2 0.1 0.6 0.1 09/30/2004 00:30:00 3.6 0.5 4.9 2.6 3.6 0.5 4.9 2.6 0.4 0 0.4 0.4 314 6 312 305 0 0 0 0 0.2 0.1 0.6 -0.1 09/30/2004 00:40:00 3.5 0.5 4.6 2.3 3.6 0.5 4.9 2.6 0.4 0 0.4 0.4 319 9 316 305 0 0 0 0 0.4 0 0.8 0.1 09/30/2004 00:50:00 2.8 0.6 4.2 1.5 3 0.6 4.2 1.5 0.4 0 0.4 0.4 319 9 327 305 0 0 0 0 0.6 0.1 1 0.6 09/30/2004 01:00:00 3.2 0.5 4.6 2.3 3.3 0.5 4.6 2.3 0.4 0 0.4 0.4 314 9 324 305 0 0 0 0 0.3 0.1 1 -0.1 09/30/2004 01:10:00 2.9 0.6 4.6 1.9 3.1 0.5 4.6 2.3 0.4 0 0.4 0.4 325 5 323 305 0 0 0 0 0.3 0.1 0.8 -0.1 09/30/2004 01:20:00 2.9 0.4 4.2 1.9 3.1 0.4 4.6 2.3 0.4 0 0.4 0.4 324 11 330 305 0 0 0 0 0.4 0.1 1 0.1 09/30/2004 01:30:00 2.9 0.9 4.9 1.5 2.9 0.8 4.9 1.9 0.4 0 0.4 0.4 316 10 336 305 0 0 0 0 0.3 0.1 0.8 0.1 09/30/2004 01:40:00 2.5 1.3 5.3 0.4 2.6 1.1 5.3 0.7 0.4 0 0.4 0.4 294 9 299 305 0 0 0 0 0.3 0.2 1 0.1 09/30/2004 01:50:00 2.8 0.7 4.2 0.7 2.9 0.7 4.2 1.1 0.4 0 0.4 0.4 324 10 334 305 0 0 0 0 0.4 0 1 0.3 09/30/2004 02:00:00 3 0.4 3.8 1.9 3.1 0.4 3.8 2.3 0.4 0 0.4 0.4 310 6 320 305 0 0 0 0 0.5 0.1 1 0.3 09/30/2004 02:10:00 1.5 1 3.4 0.4 1.7 0.9 3.4 0.4 0.4 0 0.4 0.4 304 2 305 305 0 0 0 0 0.7 0.1 1 0.6 09/30/2004 02:20:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 304 0 305 305 0 0 0 0 0.4 0.1 1 0.1 09/30/2004 02:30:00 0.7 0.7 2.3 0.4 0.8 0.5 2.6 0.4 0.4 0 0.4 0.4 308 9 307 305 0 0 0 0 0 0 0.6 -0.1 09/30/2004 02:40:00 2.2 0.8 4.2 0.7 2.1 0.7 3.8 0.7 0.4 0 0.4 0.4 318 8 307 305 0 0 0 0 -0.1 0 0.3 -0.4 09/30/2004 02:50:00 2.5 0.5 3.8 1.1 2.4 0.5 3.4 0.7 0.4 0 0.4 0.4 303 17 281 305 0 0 0 0 -0.1 0 0.3 -0.4 09/30/2004 03:00:00 2.8 0.6 4.2 1.5 2.4 0.5 3.8 1.5 0.4 0 0.4 0.4 275 8 285 305 0 0 0 0 0.4 0.2 1 0.1 09/30/2004 03:10:00 3.8 1.1 6.1 1.5 3.2 1.1 5.3 1.1 0.4 0 0.4 0.4 277 9 285 305 0 0 0 0 1 0 1 0.8 09/30/2004 03:20:00 3.6 0.8 5.3 2.3 3.2 0.7 4.9 1.5 0.4 0 0.4 0.4 277 9 283 305 0 0 0 0 1.1 0 1.3 1 09/30/2004 03:30:00 4.7 0.7 6.5 3 4 0.6 5.3 2.6 0.4 0 0.4 0.4 271 6 273 305 0 0 0 0 1.2 0 1.3 1 09/30/2004 03:40:00 6 0.9 7.6 3.8 5.2 0.9 6.8 3.4 0.4 0 0.4 0.4 279 6 275 305 0 0 0 0 1.2 0 1.3 1 09/30/2004 03:50:00 6 0.8 8.4 4.2 4.9 1 7.2 3 0.4 0 0.4 0.4 273 7 273 305 0 0 0 0 1 0 1.3 1 09/30/2004 04:00:00 4.5 1.3 8 3 4.3 1.2 7.6 3 0.4 0 0.4 0.4 293 12 285 305 0 0 0 0 1.1 0 1.5 1 09/30/2004 04:10:00 3.1 0.5 5.3 1.5 2.8 0.5 4.2 1.5 0.4 0 0.4 0.4 286 10 307 305 0 0 0 0 1 0 1.5 0.8 09/30/2004 04:20:00 4.8 1.2 8 3.4 4.7 1 7.6 3 0.4 0 0.4 0.4 300 7 292 305 0 0 0 0 1 0 1.5 1 09/30/2004 04:30:00 5.4 0.9 7.6 3.8 5.2 0.9 7.2 2.6 0.4 0 0.4 0.4 289 10 297 305 0 0 0 0 1 0 1.5 1 09/30/2004 04:40:00 2.5 0.8 4.9 0.7 2.4 0.7 4.2 0.7 0.4 0 0.4 0.4 257 9 263 305 0 0 0 0 1.1 0.1 1.5 1 09/30/2004 04:50:00 2.9 1.1 4.9 0.7 2.9 1.1 4.6 0.7 0.4 0 0.4 0.4 298 16 305 305 0 0 0 0 1 0 1.5 1 09/30/2004 05:00:00 3.1 0.6 4.9 1.5 2.8 0.6 4.2 0.7 0.4 0 0.4 0.4 283 15 282 305 0 0 0 0 1.1 0 1.5 1 09/30/2004 05:10:00 3.8 0.7 5.7 2.3 3.8 0.6 5.7 2.3 0.4 0 0.4 0.4 297 8 302 305 0 0 0 0 1.2 0 1.5 1 09/30/2004 05:20:00 4.9 0.6 6.5 3 4.5 0.6 5.7 2.6 0.4 0 0.4 0.4 290 15 275 305 0 0 0 0 1.2 0.1 1.5 1 09/30/2004 05:30:00 3.2 0.6 4.9 1.9 3 0.5 4.2 1.5 0.4 0 0.4 0.4 256 14 278 305 0 0 0 0 1.3 0 1.5 1.3 09/30/2004 05:40:00 3.6 1 5.3 1.1 3.5 0.9 4.9 0.7 0.4 0 0.4 0.4 289 17 293 305 0 0 0 0 1.1 0 1.5 1 09/30/2004 05:50:00 3.5 0.6 4.9 2.3 3.4 0.5 4.9 2.3 0.4 0 0.4 0.4 299 6 303 305 0 0 0 0 1 0 1.5 0.8 09/30/2004 06:00:00 3.9 0.7 5.7 2.6 3.7 0.9 5.7 1.9 0.4 0 0.4 0.4 289 13 284 305 0 0 0 0 1 0 1.3 0.8 09/30/2004 06:10:00 3.1 0.7 4.6 1.1 3 0.5 4.2 1.1 0.4 0 0.4 0.4 288 10 285 305 0 0 0 0 0.9 0 1.3 0.8 09/30/2004 06:20:00 1.8 0.5 3.4 0.7 1.7 0.4 2.6 0.7 0.4 0 0.4 0.4 254 8 251 305 0 0 0 0 0.9 0 1.3 0.8 09/30/2004 06:30:00 2.7 0.6 4.2 0.7 2.5 0.6 4.6 0.7 0.4 0 0.4 0.4 274 22 287 305 0 0 0 0 1 0 1.5 1 09/30/2004 06:40:00 2.2 0.5 3.4 0.7 2.3 0.5 3.4 1.1 0.4 0 0.4 0.4 294 9 303 305 0 0 0 0 0.9 0 1.5 0.8 09/30/2004 06:50:00 3.6 0.8 5.7 1.9 3.2 0.6 4.9 1.9 0.4 0 0.4 0.4 279 13 262 305 0 0 0 0 0.9 0 1.3 0.8 09/30/2004 07:00:00 4 0.5 5.7 2.3 3.4 0.5 4.9 1.9 0.4 0 0.4 0.4 276 7 278 305 0 0 0 0 1.2 0 1.5 1 09/30/2004 07:10:00 3.1 0.6 4.6 1.9 3.1 0.6 4.6 1.9 0.4 0 0.4 0.4 298 6 305 305 0 0 0 0 1.3 0.1 1.7 1 09/30/2004 07:20:00 4.1 0.7 5.7 1.9 3.8 0.6 5.3 1.9 0.4 0 0.4 0.4 289 10 288 305 0 0 0 0 1.1 0 1.3 1 09/30/2004 07:30:00 3.7 0.8 6.1 1.9 3.2 0.8 4.9 1.5 0.4 0 0.4 0.4 275 14 262 305 0 0 0 0 1.4 0 1.5 1.3 09/30/2004 07:40:00 5.3 0.5 6.8 3.4 4.8 0.7 6.8 3 0.4 0 0.4 0.4 255 7 252 305 0 0 0 0 1.5 0 1.5 1.3 09/30/2004 07:50:00 5 0.7 6.8 3 4.6 0.7 6.5 3 0.4 0 0.4 0.4 260 16 252 305 0 0 0 0 1.6 0 1.7 1.5 09/30/2004 08:00:00 4 0.8 6.1 1.9 3.4 0.7 5.3 1.5 0.4 0 0.4 0.4 270 10 269 305 0 0 0 0 1.5 0 2 1.3 09/30/2004 08:10:00 4.4 0.9 6.1 1.9 3.7 0.7 5.7 1.9 0.4 0 0.4 0.4 265 12 258 305 0 0 0 0 1.4 0 2 1.3 09/30/2004 08:20:00 4.7 0.5 5.7 3 4.3 0.6 5.7 2.6 0.4 0 0.4 0.4 249 6 254 305 0 0 0 0 1.4 0 2 1.3 09/30/2004 08:30:00 3.4 1 6.1 1.9 3.1 0.9 4.9 1.5 0.4 0 0.4 0.4 276 11 277 305 0 0 0 0 1.3 0.1 1.7 1.3 09/30/2004 08:40:00 3 0.5 4.2 1.9 2.4 0.5 3.4 0.7 0.4 0 0.4 0.4 269 7 265 305 0 0 0 0 1.2 0.1 1.5 1 09/30/2004 08:50:00 3.3 0.5 4.6 1.9 2.9 0.5 4.2 1.5 0.4 0 0.4 0.4 257 9 261 305 0 0 0 0 1 0 1.5 1 09/30/2004 09:00:00 4.4 0.5 5.3 3 3.5 0.5 4.6 2.3 0.4 0 0.4 0.4 268 5 261 305 0 0 0 0 0.9 0 1.3 0.8 09/30/2004 09:10:00 4.2 0.4 5.7 3.4 3.5 0.5 4.9 1.9 0.4 0 0.4 0.4 269 7 266 305 0 0 0 0 1.1 0 1.5 1 09/30/2004 09:20:00 3.6 0.6 4.9 1.5 3.1 0.6 4.6 1.5 0.4 0 0.4 0.4 276 6 278 305 0 0 0 0 1.3 0 1.7 1 09/30/2004 09:30:00 3.6 0.4 4.9 3 3.2 0.5 4.2 1.9 0.4 0 0.4 0.4 276 6 273 305 0 0 0 0 1.5 0 2 1.3 09/30/2004 09:40:00 3.6 0.3 4.6 2.6 3.3 0.4 4.6 2.3 0.4 0 0.4 0.4 285 7 276 305 0 0 0 0 1.6 0 2.2 1.5 09/30/2004 09:50:00 3.8 0.5 4.9 1.9 3.4 0.5 4.6 1.5 0.4 0 0.4 0.4 278 8 263 305 0 0 0 0 1.7 0.1 2.2 1.5 09/30/2004 10:00:00 4 0.4 4.9 2.6 3.7 0.5 4.9 2.3 0.4 0 0.4 0.4 277 4 277 305 0 0 0 0 1.9 0 2.2 1.7 09/30/2004 10:10:00 3.3 0.5 4.6 1.9 2.8 0.5 4.2 1.5 0.4 0 0.4 0.4 273 5 262 305 0 0 0 0 1.9 0 2.5 1.7 09/30/2004 10:20:00 3.4 0.5 4.6 1.9 2.9 0.5 4.2 1.9 0.4 0 0.4 0.4 273 8 261 305 0 0 0 0 2 0 2.5 2 09/30/2004 10:30:00 3.9 0.4 4.9 2.6 3.5 0.5 4.6 2.3 0.4 0 0.4 0.4 278 7 293 305 0 0 0 0 2.2 0 2.7 2.2 09/30/2004 10:40:00 3.8 0.5 4.6 2.6 3.2 0.5 4.6 2.3 0.4 0 0.4 0.4 272 6 275 305 0 0 0 0 2.2 0 2.5 2 09/30/2004 10:50:00 4.1 0.5 5.3 2.6 3.4 0.5 4.9 1.9 0.4 0 0.4 0.4 272 7 276 305 0 0 0 0 2.3 0.1 2.7 2.2 09/30/2004 11:00:00 4.1 0.6 5.7 2.3 3.3 0.6 4.9 1.5 0.4 0 0.4 0.4 268 8 268 305 0 0 0 0 2.4 0 2.7 2.2 09/30/2004 11:10:00 4.7 0.6 6.1 3.4 3.8 0.6 5.7 2.3 0.4 0 0.4 0.4 273 7 269 305 0 0 0 0 2.6 0 3.2 2.5 09/30/2004 11:20:00 4 0.7 5.7 2.3 3.3 0.6 4.6 1.5 0.4 0 0.4 0.4 268 8 278 305 0 0 0 0 2.8 0.1 3.4 2.5 09/30/2004 11:30:00 3.6 0.7 4.9 1.9 3.3 0.7 4.9 1.9 0.4 0 0.4 0.4 258 7 256 305 0 0 0 0 2.9 0.1 3.4 2.9 09/30/2004 11:40:00 4.8 0.8 6.1 2.6 4.4 1 5.7 2.3 0.4 0 0.4 0.4 258 7 252 305 0 0 0 0 3.3 0.2 3.7 2.9 09/30/2004 11:50:00 4.4 0.5 5.7 3 4.4 0.6 5.7 2.6 0.4 0 0.4 0.4 251 5 251 305 0 0 0 0 3.3 0.1 3.7 3.2 09/30/2004 12:00:00 3.9 0.5 5.3 2.6 3.9 0.6 4.9 2.3 0.4 0 0.4 0.4 247 7 258 305 0 0 0 0 3.4 0.1 3.7 3.2 09/30/2004 12:10:00 4.1 0.5 5.3 3 4 0.5 5.3 2.6 0.4 0 0.4 0.4 237 8 241 305 0 0 0 0 3.5 0 3.7 3.4 09/30/2004 12:20:00 4.5 0.6 6.1 3 4.2 0.6 6.1 3 0.4 0 0.4 0.4 234 4 237 305 0 0 0 0 3.7 0 4.2 3.4 09/30/2004 12:30:00 4.4 0.4 5.3 3.4 4.1 0.5 5.3 2.6 0.4 0 0.4 0.4 234 5 240 305 0 0 0 0 3.8 0 4.2 3.7 09/30/2004 12:40:00 4.3 0.4 5.3 3 4.2 0.4 4.9 3 0.4 0 0.4 0.4 232 4 232 305 0 0 0 0 3.9 0.1 4.4 3.7 09/30/2004 12:50:00 4.1 0.4 4.9 3 3.9 0.4 4.9 2.3 0.4 0 0.4 0.4 227 5 228 305 0 0 0 0 4 0.1 4.4 3.7 09/30/2004 13:00:00 4.2 0.4 4.9 3 3.9 0.4 4.9 3 0.4 0 0.4 0.4 223 5 227 305 0 0 0 0 4.3 0.1 4.9 4.2 09/30/2004 13:10:00 4.2 0.3 4.9 3.4 4 0.4 4.6 3 0.4 0 0.4 0.4 218 4 220 305 0 0 0 0 4.4 0.1 4.9 4.4 09/30/2004 13:20:00 4.8 0.8 6.8 3 4.4 0.8 6.1 2.6 0.4 0 0.4 0.4 221 13 222 305 0 0 0 0 4.5 0.1 4.9 4.4 09/30/2004 13:30:00 6 0.7 8 3.8 5.4 0.7 7.2 3.4 0.4 0 0.4 0.4 243 6 248 305 0 0 0 0 4.9 0.1 5.4 4.4 09/30/2004 13:40:00 6.6 0.9 8.8 4.2 6.1 0.9 8.4 3.8 0.4 0 0.4 0.4 246 6 249 305 0 0 0 0 5 0.1 5.4 4.9 09/30/2004 13:50:00 6.6 0.9 9.1 3.8 6 1 8 3.4 0.4 0 0.4 0.4 249 8 248 305 0 0 0 0 5 0.2 5.4 4.9 09/30/2004 14:00:00 6.6 1 8.8 4.2 6 1 8.8 3.4 0.4 0 0.4 0.4 249 6 248 305 0 0 0 0 5.1 0.2 5.6 4.9 09/30/2004 14:10:00 7.6 1.1 9.5 4.9 7.1 1.1 9.1 4.6 0.4 0 0.4 0.4 249 6 246 305 0 0 0 0 5.1 0.2 5.6 4.9 09/30/2004 14:20:00 8 0.9 9.5 5.3 7.3 1 9.1 4.9 0.4 0 0.4 0.4 244 5 247 305 0 0 0 0 5.2 0.2 5.9 4.9 09/30/2004 14:30:00 7 0.7 8.4 4.9 6.4 0.7 8 4.6 0.4 0 0.4 0.4 230 6 233 305 0 0 0 0 5.4 0.1 5.9 5.2 09/30/2004 14:40:00 6.4 0.7 8 4.2 5.9 0.7 7.6 4.2 0.4 0 0.4 0.4 232 6 238 305 0 0 0 0 5.3 0.2 5.9 4.9 09/30/2004 14:50:00 8.1 0.8 9.5 5.7 7.5 0.8 9.1 4.6 0.4 0 0.4 0.4 233 5 233 305 0 0 0 0 5.1 0.2 5.6 4.7 09/30/2004 15:00:00 7.5 0.7 9.1 5.3 6.7 0.8 8.8 4.6 0.4 0 0.4 0.4 234 6 224 305 0 0 0 0 4.8 0.1 5.4 4.7 09/30/2004 15:10:00 7.5 0.8 9.1 5.7 6.8 0.7 8.4 5.3 0.4 0 0.4 0.4 236 6 231 305 0 0 0 0 4.9 0 5.4 4.7 09/30/2004 15:20:00 7.6 0.8 9.5 5.7 6.9 0.9 9.1 4.6 0.4 0 0.4 0.4 237 6 246 305 0 0 0 0 4.9 0.1 5.4 4.7 09/30/2004 15:30:00 7.5 0.7 9.1 5.7 7 0.9 8.8 4.6 0.4 0 0.4 0.4 227 7 234 305 0 0 0 0 5 0.2 5.6 4.9 09/30/2004 15:40:00 7.5 0.7 9.1 5.7 6.9 0.8 8.8 4.9 0.4 0 0.4 0.4 224 5 224 305 0 0 0 0 5.3 0.1 5.9 5.2 09/30/2004 15:50:00 8 0.5 9.1 6.1 7.5 0.6 8.8 5.7 0.4 0 0.4 0.4 216 4 216 305 0 0 0 0 5.4 0.1 5.9 5.4 09/30/2004 16:00:00 7.9 0.5 9.1 6.1 7.6 0.6 9.1 5.7 0.4 0 0.4 0.4 214 4 208 305 0 0 0 0 5.2 0.2 5.9 4.7 09/30/2004 16:10:00 8 0.5 9.1 6.1 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 218 3 218 305 0 0 0 0 4.4 0.1 4.9 4.2 09/30/2004 16:20:00 6.8 0.5 8 4.6 6.7 0.6 8 4.6 0.4 0 0.4 0.4 210 6 214 305 0 0 0 0 4.4 0.1 4.9 4.4 09/30/2004 16:30:00 6.5 0.4 7.6 5.7 6.5 0.4 7.6 5.7 0.4 0 0.4 0.4 205 2 206 305 0 0 0 0 4.4 0.1 4.9 4.4 09/30/2004 16:40:00 6.6 0.6 7.6 4.6 6.5 0.6 8 4.9 0.4 0 0.4 0.4 205 3 203 305 0 0 0 0 4.4 0.1 4.9 4.4 09/30/2004 16:50:00 7.1 0.4 8 6.1 7.1 0.4 8 5.7 0.4 0 0.4 0.4 202 2 203 305 0 0 0 0 4.4 0.1 4.9 4.4 09/30/2004 17:00:00 7.2 0.4 8 6.1 7.2 0.5 8.4 5.3 0.4 0 0.4 0.4 200 4 203 305 0 0 0 0 4.4 0.1 4.9 4.4 09/30/2004 17:10:00 7.7 0.4 8.8 6.5 7.5 0.5 8.4 5.7 0.4 0 0.4 0.4 196 2 197 305 0 0 0 0 4.4 0 4.7 4.2 09/30/2004 17:20:00 7.4 0.4 8 6.1 7.2 0.5 8 5.7 0.4 0 0.4 0.4 194 3 196 305 0 0 0 0 4.4 0.1 4.7 4.2 09/30/2004 17:30:00 7.2 0.4 8.4 6.5 6.9 0.5 8.4 5.3 0.4 0 0.4 0.4 193 3 195 305 0 0 0 0 4.4 0.1 4.9 4.2 09/30/2004 17:40:00 7.2 0.3 8 6.1 6.9 0.5 8 4.9 0.4 0 0.4 0.4 193 3 194 305 0 0 0 0 4.4 0.1 4.9 4.2 09/30/2004 17:50:00 6.7 0.6 8 4.6 6.6 0.6 8 4.6 0.4 0 0.4 0.4 188 5 194 305 0 0 0 0 4.3 0 4.9 4.2 09/30/2004 18:00:00 7.1 0.5 8 5.7 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 186 3 183 305 0 0 0 0 4.4 0.1 4.7 4.2 09/30/2004 18:10:00 6.6 0.8 8.4 4.6 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 184 4 185 305 0 0 0 0 4.3 0 4.7 4.2 09/30/2004 18:20:00 6.2 1 8 3.8 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 183 5 190 305 0 0 0 0 4.3 0 4.7 4.2 09/30/2004 18:30:00 6.5 0.7 8.4 4.2 6.8 0.6 8.4 4.6 0.4 0 0.4 0.4 184 4 181 305 0 0 0 0 4.4 0 4.7 4.2 09/30/2004 18:40:00 6.9 0.8 8.4 3.8 7.3 0.6 8.8 5.3 0.4 0 0.4 0.4 183 4 191 305 0 0 0 0 4.3 0 4.7 4.2 09/30/2004 18:50:00 6.8 1 9.1 4.2 7.7 0.8 9.9 5.3 0.4 0 0.4 0.4 179 4 183 305 0 0 0 0 4.4 0 4.7 4.2 09/30/2004 19:00:00 6.7 1 8.8 3.4 7.4 0.7 8.8 5.3 0.4 0 0.4 0.4 181 5 185 305 0 0 0 0 4.3 0 4.9 4.2 09/30/2004 19:10:00 6.9 0.7 8.8 4.2 7.2 0.5 8.8 5.7 0.4 0 0.4 0.4 182 3 177 305 0 0 0 0 4.2 0 4.7 4.2 09/30/2004 19:20:00 7.8 1 9.5 4.2 8.3 0.8 9.9 6.1 0.4 0 0.4 0.4 181 4 184 305 0 0 0 0 4.2 0 4.7 4.2 09/30/2004 19:30:00 7.5 1.3 9.9 3.8 8.5 0.8 10.3 6.5 0.4 0 0.4 0.4 179 6 184 305 0 0 0 0 4.3 0 4.7 4.2 09/30/2004 19:40:00 7.9 1.5 11.1 4.6 8.9 1 11.5 6.1 0.4 0 0.4 0.4 179 6 188 305 0 0 0 0 4.4 0 4.7 4.2 09/30/2004 19:50:00 8.1 1.2 10.7 4.6 8.9 0.9 10.7 6.1 0.4 0 0.4 0.4 180 5 185 305 0 0 0 0 4.4 0 4.7 4.2 09/30/2004 20:00:00 8.5 1.1 10.7 4.9 9.1 0.8 10.7 6.8 0.4 0 0.4 0.4 181 5 184 305 0 0 0 0 4.4 0 4.7 4.2 09/30/2004 20:10:00 9 1 11.1 5.7 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 182 4 181 305 0 0 0 0 4.3 0 4.7 4.2 09/30/2004 20:20:00 8.5 1.2 10.7 4.6 9.4 1 11.5 6.1 0.4 0 0.4 0.4 180 4 183 305 0 0 0 0 4.3 0 4.7 4.2 09/30/2004 20:30:00 8.6 1.4 11.5 4.6 9.6 1 11.5 6.5 0.4 0 0.4 0.4 180 5 183 305 0 0 0 0 4.4 0 4.7 4.2 09/30/2004 20:40:00 9 1.2 11.5 5.3 9.9 1 12.2 7.6 0.4 0 0.4 0.4 180 5 188 305 0 0 0 0 4.4 0 4.7 4.2 09/30/2004 20:50:00 9.5 1.1 11.8 5.3 10.2 0.8 13 8 0.4 0 0.4 0.4 182 4 182 305 0 0 0 0 4.3 0 4.7 4.2 09/30/2004 21:00:00 7.8 1.5 10.7 4.6 9.1 0.9 11.5 6.8 0.4 0 0.4 0.4 178 6 188 305 0 0 0 0 4.3 0.1 4.7 4.2 09/30/2004 21:10:00 7.5 1.3 10.3 4.9 9.3 0.8 11.5 6.8 0.4 0 0.4 0.4 177 6 188 305 0 0 0 0 4.5 0.1 4.9 4.4 09/30/2004 21:20:00 7.2 1.2 10.3 4.6 9.3 0.8 11.5 7.6 0.4 0 0.4 0.4 173 5 180 305 0 0 0 0 4.5 0.1 4.9 4.4 09/30/2004 21:30:00 8 1.5 11.8 4.9 10 0.9 11.8 8 0.4 0 0.4 0.4 176 6 183 305 0 0 0 0 4.5 0.1 4.9 4.4 09/30/2004 21:40:00 8.2 1.2 10.7 5.3 10.1 0.8 12.2 7.6 0.4 0 0.4 0.4 178 5 188 305 0 0 0 0 4.5 0.1 4.9 4.4 09/30/2004 21:50:00 7.7 1.3 11.1 4.6 9.2 0.9 11.5 6.8 0.4 0 0.4 0.4 178 6 186 305 0 0 0 0 4.6 0.1 5.2 4.4 09/30/2004 22:00:00 6.9 1.2 10.7 4.6 9.3 1 11.8 6.5 0.4 0 0.4 0.4 171 6 183 305 0 0 0 0 4.6 0 4.9 4.4 09/30/2004 22:10:00 7.2 1.1 10.3 4.6 9.4 1.2 12.2 6.5 0.4 0 0.4 0.4 171 6 169 305 0 0 0 0 4.5 0.1 4.9 4.4 09/30/2004 22:20:00 7.3 1.1 10.3 4.9 9.1 1 11.8 6.1 0.4 0 0.4 0.4 167 6 177 305 0 0 0 0 4.7 0.2 5.2 4.4 09/30/2004 22:30:00 7.3 1.1 11.1 4.9 9.1 0.8 11.1 7.2 0.4 0 0.4 0.4 167 6 160 305 0 0 0 0 4.4 0.1 4.9 4.2 09/30/2004 22:40:00 6.8 1 9.1 4.9 8.4 0.8 10.3 6.1 0.4 0 0.4 0.4 166 6 160 305 0 0 0 0 4.4 0 4.7 4.2 09/30/2004 22:50:00 7.1 1.2 10.7 4.2 8.8 1 11.5 6.5 0.4 0 0.4 0.4 169 7 169 305 0 0 0 0 4.5 0.1 4.9 4.4 09/30/2004 23:00:00 8.3 1 12.2 4.9 10.2 1.2 14.5 6.8 0.4 0 0.4 0.4 167 6 165 305 0 0 0 0 4.9 0.1 5.4 4.7 09/30/2004 23:10:00 8.4 1.1 11.8 5.7 10.5 1.3 13.7 7.2 0.4 0 0.4 0.4 167 6 179 305 0 0 0 0 5.2 0.1 5.6 4.9 09/30/2004 23:20:00 8.1 1.2 11.5 5.3 10 1.2 13.7 7.2 0.4 0 0.4 0.4 168 7 170 305 0 0 0 0 5.3 0 5.6 5.2 09/30/2004 23:30:00 8.5 1.2 11.8 4.9 10.2 1.3 14.5 6.8 0.4 0 0.4 0.4 167 7 152 305 0 0 0 0 5.3 0 5.6 5.4 09/30/2004 23:40:00 9.4 1.3 12.6 6.5 10.7 1.1 13.7 7.6 0.4 0 0.4 0.4 163 6 162 305 0 0 0 0 5.3 0 5.6 5.2 09/30/2004 23:50:00 9 1.2 13 6.1 11 1.2 13.3 7.6 0.4 0 0.4 0.4 167 6 155 305 0 0 0 0 5.4 0.2 5.9 5.2 10/01/2004 00:00:00 9.4 1.2 13.3 6.5 11 1 14.1 8.4 0.4 0 0.4 0.4 164 6 165 305 0 0 0 0 5.5 0 5.9 5.4 10/01/2004 00:10:00 9.1 1.3 12.6 5.7 9.9 1.1 12.6 6.8 0.4 0 0.4 0.4 161 6 165 305 0 0 0 0 5.3 0.1 5.9 4.9 10/01/2004 00:20:00 7.8 1 10.7 5.3 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 165 7 163 305 0 0 0 0 5.2 0.1 5.6 4.9 10/01/2004 00:30:00 7.7 1 10.7 4.9 9.4 0.8 12.2 6.8 0.4 0 0.4 0.4 167 6 168 305 0 0 0 0 5.3 0 5.6 5.2 10/01/2004 00:40:00 7.8 1 10.7 5.3 9.7 1.2 12.6 6.5 0.4 0 0.4 0.4 170 7 174 305 0 0 0 0 5.6 0.2 6.4 5.4 10/01/2004 00:50:00 8.5 1.5 11.5 4.9 10.5 0.9 12.6 7.6 0.4 0 0.4 0.4 176 6 184 305 0 0 0 0 6.6 0.1 7.2 6.1 10/01/2004 01:00:00 9.2 1.3 11.8 5.7 10.3 1 12.6 7.2 0.4 0 0.4 0.4 179 5 189 305 0 0 0 0 6.7 0.1 7.2 6.7 10/01/2004 01:10:00 9.6 1.1 11.8 6.1 10.4 0.8 12.6 7.6 0.4 0 0.4 0.4 182 4 188 305 0 0 0 0 6.8 0.2 7.4 6.7 10/01/2004 01:20:00 9.8 0.7 11.1 6.5 10.4 0.6 11.8 8 0.4 0 0.4 0.4 182 3 187 305 0 0 0 0 6.8 0.1 7.2 6.7 10/01/2004 01:30:00 9.6 0.8 11.1 6.5 10.2 0.7 11.8 8 0.4 0 0.4 0.4 183 3 187 305 0 0 0 0 6.9 0 7.4 6.7 10/01/2004 01:40:00 8.9 0.7 10.7 5.7 9.4 0.7 11.1 7.2 0.4 0 0.4 0.4 184 4 182 305 323 22 319 0 6.7 0.2 7.4 6.4 10/01/2004 01:50:00 8 0.5 9.9 6.5 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 188 3 187 305 336 56 319 0 6.4 0.1 6.9 6.1 10/01/2004 02:00:00 8.1 0.5 9.5 7.2 8 0.5 9.1 6.8 0.4 0 0.4 0.4 188 3 187 305 73 1 73 0 6.4 0.1 6.9 6.1 10/01/2004 02:10:00 9 0.5 10.3 7.6 8.7 0.6 10.3 6.5 0.4 0 0.4 0.4 189 3 187 305 76 1 79 0 6.3 0.2 6.9 6.1 10/01/2004 02:20:00 9 0.5 10.7 7.6 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 189 3 192 305 84 5 80 0 6.3 0.2 6.9 5.9 10/01/2004 02:30:00 9.5 0.5 10.7 8.4 9.1 0.6 10.3 6.5 0.4 0 0.4 0.4 191 3 194 305 92 1 92 0 6.1 0.2 6.7 5.9 10/01/2004 02:40:00 9.6 0.5 10.7 7.6 9.1 0.7 10.7 6.8 0.4 0 0.4 0.4 191 3 193 305 93 1 94 0 6.1 0.2 6.4 5.9 10/01/2004 02:50:00 9.7 0.5 11.1 7.6 9.2 0.6 10.7 7.2 0.4 0 0.4 0.4 192 3 196 305 93 4 95 0 6.1 0.2 6.4 5.9 10/01/2004 03:00:00 10 0.4 11.1 8.8 9.3 0.6 10.7 6.8 0.4 0 0.4 0.4 192 2 194 305 84 0 84 0 6 0.1 6.4 5.9 10/01/2004 03:10:00 9.7 0.4 11.1 8.8 9.2 0.6 10.7 7.2 0.4 0 0.4 0.4 192 3 194 305 84 0 84 0 5.9 0 6.4 5.6 10/01/2004 03:20:00 9.3 0.5 10.7 8.4 8.9 0.6 10.7 6.8 0.4 0 0.4 0.4 191 3 192 305 85 0 85 0 5.9 0 6.4 5.6 10/01/2004 03:30:00 9.1 0.5 10.3 7.6 8.8 0.6 10.3 6.8 0.4 0 0.4 0.4 188 3 187 305 86 0 86 0 6 0.1 6.4 5.9 10/01/2004 03:40:00 9.3 0.6 10.7 7.2 9 0.6 10.7 6.5 0.4 0 0.4 0.4 188 3 192 305 87 0 86 0 6.2 0.2 6.7 5.9 10/01/2004 03:50:00 9.1 0.5 10.3 7.6 9 0.5 10.3 6.8 0.4 0 0.4 0.4 188 3 188 305 87 0 87 0 6.1 0.2 6.7 5.9 10/01/2004 04:00:00 9.1 0.6 11.1 7.2 9 0.6 10.3 7.2 0.4 0 0.4 0.4 187 3 188 305 87 0 87 0 6.3 0.2 6.7 6.1 10/01/2004 04:10:00 9.1 0.8 11.1 6.5 9.1 0.8 11.5 6.8 0.4 0 0.4 0.4 186 4 184 305 88 0 88 0 6.3 0.1 6.9 6.1 10/01/2004 04:20:00 9 1 11.1 6.5 9.4 0.7 11.5 6.8 0.4 0 0.4 0.4 183 4 188 305 89 0 88 0 6.5 0.2 7.4 6.1 10/01/2004 04:30:00 8.9 0.9 11.1 5.7 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 183 4 184 305 89 0 90 0 7.2 0.2 7.7 6.9 10/01/2004 04:40:00 8.9 0.9 11.1 6.1 9.2 0.9 11.5 6.5 0.4 0 0.4 0.4 183 4 185 305 90 0 90 0 7.6 0.2 8.2 7.4 10/01/2004 04:50:00 9.4 0.9 11.8 7.2 9.5 0.8 11.8 7.2 0.4 0 0.4 0.4 185 4 186 305 90 0 91 0 8 0.2 8.7 7.9 10/01/2004 05:00:00 10.2 0.9 13 7.2 10.1 0.9 12.6 6.8 0.4 0 0.4 0.4 186 3 188 305 91 0 91 0 8.6 0.2 9.5 8.2 10/01/2004 05:10:00 10.6 0.8 13 8.4 10.3 1 12.2 7.2 0.4 0 0.4 0.4 187 4 192 305 92 0 92 0 8.9 0.2 9.5 8.7 10/01/2004 05:20:00 11 0.7 13 8.8 10.7 0.7 12.2 8 0.4 0 0.4 0.4 186 4 187 305 93 0 92 0 9.2 0.2 9.7 8.9 10/01/2004 05:30:00 10.8 0.8 12.6 7.2 10.9 0.8 13 8 0.4 0 0.4 0.4 185 4 188 305 93 0 93 0 9.3 0.2 10 9.2 10/01/2004 05:40:00 10.5 1 12.6 7.2 10.6 0.9 13 8.4 0.4 0 0.4 0.4 185 4 193 305 94 0 94 0 9.6 0.2 10 9.5 10/01/2004 05:50:00 10.5 0.9 12.6 7.2 10.5 0.9 13 7.6 0.4 0 0.4 0.4 185 4 189 305 95 0 94 0 9.7 0.2 10.2 9.5 10/01/2004 06:00:00 11 0.8 13 8 10.8 0.8 12.6 7.6 0.4 0 0.4 0.4 186 3 186 305 95 0 94 0 9.8 0.2 10.5 9.7 10/01/2004 06:10:00 11.2 0.8 13 8.8 11.1 0.8 13 8.8 0.4 0 0.4 0.4 186 3 190 305 96 0 96 0 9.9 0.2 10.2 9.7 10/01/2004 06:20:00 11 0.9 13 8 10.8 0.9 13 7.6 0.4 0 0.4 0.4 186 4 189 305 97 0 96 0 9.8 0.1 10.5 9.7 10/01/2004 06:30:00 11.2 0.8 13 9.1 11 0.9 13 7.2 0.4 0 0.4 0.4 187 4 190 305 97 0 97 0 10.1 0.2 10.8 9.7 10/01/2004 06:40:00 11.4 0.8 14.1 9.5 11 1 13.3 8.4 0.4 0 0.4 0.4 189 4 190 305 98 0 98 0 10.3 0.2 10.8 10.2 10/01/2004 06:50:00 11.6 0.8 13.7 9.9 11.2 0.9 13.7 8.4 0.4 0 0.4 0.4 189 3 192 305 98 0 99 0 10.4 0.2 10.8 10.2 10/01/2004 07:00:00 11.6 0.7 13.7 9.1 10.8 1 13.3 8 0.4 0 0.4 0.4 190 3 191 305 99 0 98 0 10.4 0.2 11 10.2 10/01/2004 07:10:00 11.7 0.7 13.3 9.5 10.9 0.9 13.3 8.4 0.4 0 0.4 0.4 192 3 192 305 99 0 99 0 10.4 0.2 11 10.2 10/01/2004 07:20:00 11.2 0.8 13.7 8.8 10.4 1 13 7.2 0.4 0 0.4 0.4 191 4 195 305 100 0 100 0 10.4 0.2 11 10.2 10/01/2004 07:30:00 11.5 0.7 13.3 9.1 10.9 0.8 12.6 8 0.4 0 0.4 0.4 190 3 191 305 100 0 100 0 10.4 0.2 11 10.2 10/01/2004 07:40:00 12.1 0.7 13.7 9.5 11.4 0.8 13.3 8.8 0.4 0 0.4 0.4 191 3 193 305 101 0 101 0 10.5 0.2 11 10.2 10/01/2004 07:50:00 12.1 0.7 14.5 9.9 11.4 1 13.3 8.8 0.4 0 0.4 0.4 192 3 188 305 101 0 101 0 10.4 0.2 11 10.2 10/01/2004 08:00:00 12.5 0.7 14.9 10.3 11.8 0.9 14.1 8.8 0.4 0 0.4 0.4 193 3 192 305 99 1 98 0 10 0.2 10.8 10 10/01/2004 08:10:00 12.6 0.7 14.5 10.7 11.8 0.9 14.1 9.1 0.4 0 0.4 0.4 193 3 194 305 99 0 99 0 9.9 0.1 10.5 9.7 10/01/2004 08:20:00 12.6 0.7 14.5 10.7 11.9 1 14.1 8.8 0.4 0 0.4 0.4 194 3 192 305 99 0 99 0 9.7 0.1 10.2 9.5 10/01/2004 08:30:00 12.3 0.6 14.1 10.3 11.6 0.8 13.7 9.1 0.4 0 0.4 0.4 195 3 195 305 99 1 99 0 9.5 0.2 10 9.2 10/01/2004 08:40:00 12.2 0.6 13.7 10.7 11.7 0.8 13.3 9.5 0.4 0 0.4 0.4 195 3 194 305 98 0 98 0 9.3 0.1 9.7 9.2 10/01/2004 08:50:00 12.4 0.5 14.1 10.7 11.8 0.7 13.3 9.5 0.4 0 0.4 0.4 195 3 203 305 98 0 98 0 9.3 0.2 10 8.9 10/01/2004 09:00:00 12.2 0.5 13.7 10.7 11.7 0.7 13 9.9 0.4 0 0.4 0.4 196 2 198 305 100 5 109 0 6.8 1.4 14.8 6.1 10/01/2004 09:10:00 12 0.5 13 10.7 11.4 0.6 12.6 9.1 0.4 0 0.4 0.4 196 2 194 305 93 1 99 0 6.2 0.2 6.7 5.9 10/01/2004 09:20:00 12 0.5 13.3 9.5 11.3 0.6 12.6 9.5 0.4 0 0.4 0.4 195 2 196 305 94 1 92 0 6.1 0.1 6.7 5.9 10/01/2004 09:30:00 11.9 0.5 13.3 11.1 11.3 0.7 13 9.1 0.4 0 0.4 0.4 195 3 198 305 96 1 96 0 6.1 0.1 6.7 5.9 10/01/2004 09:40:00 11.4 0.6 13 9.5 10.7 0.7 12.2 8.4 0.4 0 0.4 0.4 196 3 192 305 94 1 93 0 6 0.1 6.4 5.9 10/01/2004 09:50:00 11.1 0.6 12.6 9.5 10.6 0.7 12.6 8.4 0.4 0 0.4 0.4 197 3 201 305 96 1 96 0 6 0.1 6.4 5.9 10/01/2004 10:00:00 11 0.5 12.2 9.5 10.4 0.7 12.2 8.4 0.4 0 0.4 0.4 196 3 197 305 99 1 98 0 6 0 6.4 5.6 10/01/2004 10:10:00 10.8 0.7 12.6 8 10.2 0.8 11.8 7.6 0.4 0 0.4 0.4 195 3 194 305 94 5 101 0 5.8 0.1 6.1 5.6 10/01/2004 10:20:00 10.5 0.7 12.2 8.8 9.9 0.7 11.8 7.6 0.4 0 0.4 0.4 195 3 200 305 94 1 93 0 5.8 0.1 6.1 5.6 10/01/2004 10:30:00 10.9 0.5 12.2 9.5 10.2 0.7 11.8 8 0.4 0 0.4 0.4 194 3 194 305 96 0 96 0 6 0.2 6.4 5.6 10/01/2004 10:40:00 11 0.6 12.6 8.4 10.3 0.9 12.2 8 0.4 0 0.4 0.4 193 3 193 305 97 0 97 0 6.1 0.2 6.7 5.9 10/01/2004 10:50:00 10.7 0.5 12.2 9.1 10 0.7 12.2 8 0.4 0 0.4 0.4 192 3 193 305 98 0 98 0 6.3 0.2 6.9 6.1 10/01/2004 11:00:00 10.6 0.6 12.2 8.8 9.9 0.8 11.5 7.2 0.4 0 0.4 0.4 190 3 189 305 98 2 98 0 6.3 0.1 6.9 6.1 10/01/2004 11:10:00 10.4 0.5 11.8 8.4 9.9 0.7 11.5 7.2 0.4 0 0.4 0.4 188 3 187 305 90 1 91 0 6.4 0.1 6.9 6.1 10/01/2004 11:20:00 10.4 0.6 11.8 8.8 10.1 0.7 11.8 6.8 0.4 0 0.4 0.4 188 3 189 305 88 0 88 0 6.5 0.1 7.2 6.1 10/01/2004 11:30:00 10.5 0.5 11.8 9.1 10.1 0.7 11.8 7.6 0.4 0 0.4 0.4 188 3 192 305 87 1 87 0 6.6 0.1 7.2 6.4 10/01/2004 11:40:00 10.9 0.7 13.3 9.1 10.3 0.9 12.6 7.6 0.4 0 0.4 0.4 190 3 192 305 84 0 83 0 6.6 0.1 7.2 6.4 10/01/2004 11:50:00 11.3 0.7 13 8.8 10.6 0.9 12.6 7.6 0.4 0 0.4 0.4 191 3 196 305 82 0 86 0 6.7 0.2 7.2 6.4 10/01/2004 12:00:00 11.8 0.7 13.3 9.9 11.1 0.9 13 8.4 0.4 0 0.4 0.4 192 3 191 305 81 0 81 0 6.7 0.1 7.2 6.4 10/01/2004 12:10:00 11.4 0.6 13 9.9 10.6 0.8 12.6 8 0.4 0 0.4 0.4 193 3 193 305 80 0 81 0 6.6 0.1 7.2 6.4 10/01/2004 12:20:00 11.1 0.5 12.2 9.1 10.5 0.7 11.8 7.6 0.4 0 0.4 0.4 194 3 194 305 80 0 80 0 6.6 0.1 7.2 6.4 10/01/2004 12:30:00 11 0.5 12.6 9.5 10.4 0.8 12.2 8 0.4 0 0.4 0.4 194 3 194 305 80 0 80 0 6.5 0.1 7.2 6.4 10/01/2004 12:40:00 10.8 0.5 12.2 9.1 10.2 0.7 12.2 8.4 0.4 0 0.4 0.4 193 3 194 305 79 0 79 0 6.6 0.2 7.2 6.4 10/01/2004 12:50:00 10.9 0.5 12.6 9.5 10 0.8 11.8 7.6 0.4 0 0.4 0.4 191 3 194 305 79 0 79 0 6.7 0.1 7.2 6.4 10/01/2004 13:00:00 11.2 0.6 12.6 8.8 10.5 0.9 12.2 8.4 0.4 0 0.4 0.4 192 3 190 305 83 2 84 0 6.8 0.1 7.2 6.7 10/01/2004 13:10:00 11.4 0.5 13.3 10.3 10.8 0.7 12.6 8 0.4 0 0.4 0.4 193 2 194 305 83 0 84 0 6.8 0.1 7.2 6.7 10/01/2004 13:20:00 11.1 0.5 13 8.8 10.6 0.7 12.2 8.8 0.4 0 0.4 0.4 194 3 196 305 84 0 84 0 6.8 0.2 7.2 6.4 10/01/2004 13:30:00 11 0.6 12.6 8.4 10.5 0.7 12.2 7.6 0.4 0 0.4 0.4 195 3 197 305 83 0 83 0 6.7 0.1 7.2 6.4 10/01/2004 13:40:00 10.6 0.4 11.8 9.1 10.1 0.5 11.5 8.4 0.4 0 0.4 0.4 195 3 193 305 82 0 82 0 6.7 0.2 7.2 6.4 10/01/2004 13:50:00 10.4 0.5 12.2 8.8 9.7 0.7 11.5 7.6 0.4 0 0.4 0.4 193 3 193 305 82 0 82 0 6.7 0.2 7.2 6.4 10/01/2004 14:00:00 10.3 0.4 11.5 8.8 9.6 0.6 11.1 7.6 0.4 0 0.4 0.4 193 2 194 305 81 0 82 0 6.7 0.1 7.2 6.4 10/01/2004 14:10:00 10.6 0.4 11.8 9.1 10 0.6 11.1 8.4 0.4 0 0.4 0.4 195 2 195 305 81 0 82 0 6.7 0.2 7.2 6.4 10/01/2004 14:20:00 10.7 0.5 11.8 9.5 10.3 0.6 12.2 8 0.4 0 0.4 0.4 195 2 194 305 81 0 81 0 6.8 0.2 7.2 6.4 10/01/2004 14:30:00 10.5 0.5 12.2 8.8 9.9 0.6 11.8 7.6 0.4 0 0.4 0.4 194 3 192 305 81 0 82 0 6.8 0.1 7.2 6.4 10/01/2004 14:40:00 10.3 0.6 11.8 8 9.6 0.7 11.5 7.2 0.4 0 0.4 0.4 193 3 194 305 81 0 81 0 6.8 0.1 7.2 6.7 10/01/2004 14:50:00 10.2 0.5 11.8 8.4 9.7 0.7 11.8 7.2 0.4 0 0.4 0.4 193 3 192 305 81 0 81 0 6.8 0 7.2 6.7 10/01/2004 15:00:00 10.6 0.7 12.6 8.4 10 0.8 12.2 6.8 0.4 0 0.4 0.4 193 3 191 305 81 0 81 0 6.8 0 7.2 6.7 10/01/2004 15:10:00 10.6 0.6 12.2 8.8 10.1 0.7 11.8 7.6 0.4 0 0.4 0.4 195 2 191 305 81 0 81 0 6.8 0 7.2 6.7 10/01/2004 15:20:00 10.9 0.5 13 9.1 10.3 0.8 12.6 7.2 0.4 0 0.4 0.4 196 3 193 305 80 0 80 0 6.8 0.1 7.2 6.7 10/01/2004 15:30:00 11 0.5 12.2 9.5 10.5 0.6 11.8 8.4 0.4 0 0.4 0.4 197 3 194 305 80 0 80 0 6.7 0.1 7.2 6.4 10/01/2004 15:40:00 10.7 0.5 11.8 9.5 10.3 0.5 11.5 8.8 0.4 0 0.4 0.4 196 2 196 305 80 0 80 0 6.6 0.1 7.2 6.4 10/01/2004 15:50:00 10.5 0.5 11.8 9.1 10 0.6 11.8 8 0.4 0 0.4 0.4 195 3 196 305 80 0 80 0 6.6 0.1 7.2 6.4 10/01/2004 16:00:00 10.8 0.5 12.2 9.1 10.1 0.8 12.2 7.2 0.4 0 0.4 0.4 194 3 197 305 80 0 80 0 6.6 0 7.2 6.4 10/01/2004 16:10:00 10.1 0.5 11.5 8.4 9.6 0.6 11.1 7.2 0.4 0 0.4 0.4 195 2 196 305 80 0 80 0 6.6 0.1 6.9 6.4 10/01/2004 16:20:00 10.3 0.5 11.5 8.4 9.7 0.7 11.1 7.6 0.4 0 0.4 0.4 193 2 194 305 79 0 79 0 6.5 0 6.9 6.4 10/01/2004 16:30:00 10.2 0.4 11.1 8.8 9.6 0.6 11.1 7.6 0.4 0 0.4 0.4 194 2 192 305 84 2 80 0 6.4 0 6.9 6.1 10/01/2004 16:40:00 9.9 0.4 10.7 8.8 9.4 0.5 10.3 7.2 0.4 0 0.4 0.4 194 2 192 305 84 0 85 0 6.3 0 6.9 6.1 10/01/2004 16:50:00 9.9 0.5 11.1 8.4 9.1 0.7 11.1 6.8 0.4 0 0.4 0.4 192 2 189 305 84 0 84 0 6.5 0 6.9 6.1 10/01/2004 17:00:00 9.5 0.4 11.1 8.4 9.1 0.6 10.7 7.6 0.4 0 0.4 0.4 193 2 196 305 83 0 83 0 6.5 0 7.2 6.1 10/01/2004 17:10:00 9.2 0.5 10.7 8 8.7 0.7 9.9 6.1 0.4 0 0.4 0.4 192 3 188 305 83 0 83 0 6.6 0.1 7.2 6.4 10/01/2004 17:20:00 8.9 0.5 9.9 6.5 8.4 0.6 9.9 6.5 0.4 0 0.4 0.4 192 3 190 305 83 0 83 0 6.6 0 7.2 6.4 10/01/2004 17:30:00 8.5 0.5 9.9 7.2 8.2 0.5 9.5 6.5 0.4 0 0.4 0.4 194 2 196 305 83 0 83 0 6.5 0 6.9 6.1 10/01/2004 17:40:00 8 0.4 9.1 6.5 7.6 0.6 8.8 5.3 0.4 0 0.4 0.4 191 2 193 305 82 0 82 0 6.5 0 7.2 6.4 10/01/2004 17:50:00 7.9 0.4 8.8 6.8 7.4 0.5 8.8 5.3 0.4 0 0.4 0.4 191 2 186 305 82 0 82 0 6.5 0 6.9 6.1 10/01/2004 18:00:00 7.7 0.4 9.1 6.8 7.4 0.5 9.1 5.3 0.4 0 0.4 0.4 189 2 190 305 82 0 82 0 6.5 0 6.9 6.1 10/01/2004 18:10:00 7.4 0.5 8.8 6.5 7.2 0.6 9.1 4.9 0.4 0 0.4 0.4 189 3 190 305 82 0 82 0 6.5 0.1 7.2 6.1 10/01/2004 18:20:00 6.9 0.4 8 6.1 6.8 0.5 8 4.9 0.4 0 0.4 0.4 187 3 184 305 81 0 82 0 6.3 0.1 6.9 6.1 10/01/2004 18:30:00 6.5 1 8.4 3 6.6 0.8 8.4 4.6 0.4 0 0.4 0.4 184 4 186 305 81 0 82 0 6.6 0.1 7.2 6.4 10/01/2004 18:40:00 5.8 0.6 7.2 3.8 6.1 0.6 7.6 4.2 0.4 0 0.4 0.4 182 3 183 305 81 0 81 0 6.8 0.1 7.4 6.4 10/01/2004 18:50:00 5.6 0.6 7.2 3.8 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 181 4 184 305 81 0 81 0 6.9 0.1 7.4 6.9 10/01/2004 19:00:00 5.7 0.8 7.6 3.4 6.5 0.6 8.4 4.6 0.4 0 0.4 0.4 179 5 177 305 81 0 81 0 7 0 7.4 6.9 10/01/2004 19:10:00 4.8 0.9 6.8 3 6.2 0.5 8 4.9 0.4 0 0.4 0.4 174 5 186 305 81 0 81 0 7 0.1 7.4 6.9 10/01/2004 19:20:00 4.9 0.9 7.2 3 6.8 0.6 8.4 5.3 0.4 0 0.4 0.4 173 6 164 305 81 0 81 0 7.1 0 7.4 6.9 10/01/2004 19:30:00 4.8 0.7 7.2 3.4 7 0.6 8.8 5.7 0.4 0 0.4 0.4 172 5 160 305 80 0 81 0 7 0 7.4 6.9 10/01/2004 19:40:00 5 0.7 7.2 3.4 7.2 0.6 8.8 4.9 0.4 0 0.4 0.4 168 5 176 305 80 0 80 0 6.8 0.1 7.4 6.7 10/01/2004 19:50:00 5.1 0.7 7.6 3.4 7 0.6 8.4 5.3 0.4 0 0.4 0.4 166 4 169 305 79 0 79 0 6.7 0.1 7.2 6.4 10/01/2004 20:00:00 5.7 1 8 3 7 0.6 8.4 5.3 0.4 0 0.4 0.4 162 4 157 305 79 0 79 0 6.6 0.1 7.2 6.4 10/01/2004 20:10:00 6.8 1 9.1 3.8 7.2 0.8 9.1 4.9 0.4 0 0.4 0.4 158 6 152 305 79 0 79 0 6.6 0.1 7.2 6.4 10/01/2004 20:20:00 6.8 1 9.1 4.2 6.9 0.7 8.8 5.3 0.4 0 0.4 0.4 154 7 142 305 79 0 78 0 6.4 0 6.9 6.1 10/01/2004 20:30:00 6.8 0.9 8.4 3.4 7.1 0.6 8.4 5.3 0.4 0 0.4 0.4 158 5 154 305 78 0 78 0 6.3 0.1 6.7 6.1 10/01/2004 20:40:00 6.5 0.9 8.4 3.4 7.1 0.6 8.8 4.9 0.4 0 0.4 0.4 159 4 152 305 78 0 78 0 6.3 0.1 6.7 6.1 10/01/2004 20:50:00 6.6 0.8 8.8 4.2 7.2 0.6 9.1 5.7 0.4 0 0.4 0.4 159 5 156 305 78 0 78 0 6.3 0.1 6.7 6.1 10/01/2004 21:00:00 6.1 1 8.8 3.8 7.2 0.5 8.8 5.7 0.4 0 0.4 0.4 161 5 155 305 78 0 78 0 6.3 0.1 6.7 6.1 10/01/2004 21:10:00 6 0.9 8.8 3 6.5 0.6 8.4 4.2 0.4 0 0.4 0.4 157 6 149 305 77 0 77 0 6.3 0.1 6.7 6.1 10/01/2004 21:20:00 7.7 0.7 9.1 5.3 7.5 0.7 9.5 5.7 0.4 0 0.4 0.4 150 5 154 305 77 0 77 0 6.2 0.2 6.7 5.9 10/01/2004 21:30:00 8 0.8 9.9 6.1 7.6 0.7 9.5 6.1 0.4 0 0.4 0.4 150 5 148 305 63 2 64 0 6.1 0.1 6.7 5.9 10/01/2004 21:40:00 8 0.8 9.5 5.7 7.7 0.8 9.5 6.1 0.4 0 0.4 0.4 149 4 150 305 67 1 66 0 6 0.2 6.4 5.9 10/01/2004 21:50:00 7.7 0.7 9.5 6.1 7.3 0.7 9.1 5.3 0.4 0 0.4 0.4 150 4 146 305 70 0 71 0 5.9 0 6.4 5.6 10/01/2004 22:00:00 7.5 0.7 9.5 5.3 7.2 0.6 8.4 5.7 0.4 0 0.4 0.4 153 4 148 305 72 0 71 0 5.8 0.1 6.1 5.6 10/01/2004 22:10:00 6.4 1 8.8 4.2 7.3 0.8 10.3 5.3 0.4 0 0.4 0.4 164 9 155 305 73 0 73 0 5.9 0.2 6.9 5.6 10/01/2004 22:20:00 5.9 1.1 9.1 3 7.6 0.8 9.9 4.9 0.4 0 0.4 0.4 174 6 180 305 74 0 74 0 6.8 0.1 7.4 6.4 10/01/2004 22:30:00 7.2 1.2 9.5 3.8 8.1 0.9 9.9 5.3 0.4 0 0.4 0.4 178 5 181 305 75 0 75 0 6.8 0 7.4 6.7 10/01/2004 22:40:00 7.5 1 9.1 4.2 8.2 0.7 9.9 5.7 0.4 0 0.4 0.4 180 4 183 305 76 0 77 0 6.8 0.2 7.2 6.7 10/01/2004 22:50:00 7.6 0.7 9.1 5.3 8.1 0.5 9.5 5.7 0.4 0 0.4 0.4 182 3 179 305 77 0 77 0 6.7 0.1 7.2 6.4 10/01/2004 23:00:00 7.3 0.8 8.4 4.6 7.6 0.6 9.1 5.3 0.4 0 0.4 0.4 181 3 183 305 78 0 78 0 6.7 0.1 7.2 6.4 10/01/2004 23:10:00 7.1 1 8.8 3.8 8 0.6 9.5 6.1 0.4 0 0.4 0.4 179 4 174 305 79 0 79 0 6.7 0.1 7.2 6.4 10/01/2004 23:20:00 7.2 0.8 9.1 4.6 8 0.6 9.5 6.1 0.4 0 0.4 0.4 179 3 181 305 79 0 79 0 6.7 0.1 7.2 6.7 10/01/2004 23:30:00 6.1 1.2 8.4 3 7.1 0.8 8.8 4.9 0.4 0 0.4 0.4 179 6 189 305 79 0 79 0 6.7 0.1 7.2 6.7 10/01/2004 23:40:00 6.3 1.3 9.1 3.4 7.4 0.9 9.5 5.3 0.4 0 0.4 0.4 178 5 181 305 80 0 79 0 6.8 0.1 7.2 6.7 10/01/2004 23:50:00 5.2 1 8.4 3 6.8 0.6 8.4 5.3 0.4 0 0.4 0.4 174 7 187 305 80 0 80 0 6.8 0.1 7.2 6.7 10/02/2004 00:00:00 4.5 0.7 6.5 2.3 5.1 0.5 6.8 4.2 0.4 0 0.4 0.4 163 9 177 305 80 0 80 0 6.3 0.2 7.4 5.9 10/02/2004 00:10:00 4.5 0.7 6.1 3 5.1 0.6 7.6 3.8 0.4 0 0.4 0.4 159 6 157 305 80 0 80 0 6 0.1 6.4 5.9 10/02/2004 00:20:00 4.9 0.7 6.5 2.6 5.2 0.5 6.5 4.2 0.4 0 0.4 0.4 155 5 150 305 80 0 80 0 6 0 6.4 5.9 10/02/2004 00:30:00 5.5 0.5 6.8 3.8 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 152 5 155 305 80 0 80 0 5.9 0 6.1 5.6 10/02/2004 00:40:00 4.7 0.7 6.8 3 5.6 0.5 7.2 4.2 0.4 0 0.4 0.4 163 8 178 305 80 0 80 0 5.8 0.1 6.1 5.6 10/02/2004 00:50:00 4.5 0.8 6.8 2.6 6 0.5 7.6 4.6 0.4 0 0.4 0.4 165 6 181 305 81 0 80 0 5.9 0 6.4 5.6 10/02/2004 01:00:00 5 0.9 7.6 2.6 6.2 0.5 7.6 4.9 0.4 0 0.4 0.4 162 5 160 305 81 0 81 0 6 0.1 6.4 5.9 10/02/2004 01:10:00 4.9 0.9 7.2 3 6 0.6 8 4.6 0.4 0 0.4 0.4 163 6 162 305 81 0 81 0 6 0.1 6.4 5.9 10/02/2004 01:20:00 5.5 0.8 7.2 3 6.4 0.6 7.6 4.6 0.4 0 0.4 0.4 161 4 156 305 81 0 81 0 6 0.1 6.4 5.9 10/02/2004 01:30:00 5.2 0.8 6.8 3 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 156 6 159 305 81 0 82 0 6 0.1 6.4 5.9 10/02/2004 01:40:00 5.5 0.5 6.8 4.2 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 149 6 152 305 82 0 82 0 5.8 0.2 6.4 5.4 10/02/2004 01:50:00 5.9 0.6 8 4.2 5.8 0.5 7.6 4.2 0.4 0 0.4 0.4 146 6 145 305 82 0 82 0 5.5 0.1 5.9 5.4 10/02/2004 02:00:00 6 0.6 7.6 4.2 5.7 0.6 7.2 4.2 0.4 0 0.4 0.4 146 7 155 305 82 0 81 0 5.6 0.2 5.9 5.4 10/02/2004 02:10:00 5.3 0.7 7.2 3 5.5 0.5 7.2 4.2 0.4 0 0.4 0.4 155 6 154 305 82 0 82 0 5.8 0.2 6.1 5.4 10/02/2004 02:20:00 5.5 1.1 8 2.6 5.8 0.8 7.6 4.2 0.4 0 0.4 0.4 156 6 151 305 83 0 82 0 6 0.1 6.4 5.6 10/02/2004 02:30:00 7 0.7 8.4 4.9 6.6 0.6 8.4 4.9 0.4 0 0.4 0.4 151 5 156 305 83 0 83 0 5.9 0.1 6.4 5.6 10/02/2004 02:40:00 8.1 0.8 9.9 5.3 7.8 0.8 9.5 5.3 0.4 0 0.4 0.4 154 4 151 305 83 0 82 0 5.9 0.1 6.4 5.6 10/02/2004 02:50:00 6.6 1 8.8 3.8 6.8 0.7 8.8 4.9 0.4 0 0.4 0.4 156 5 147 305 83 0 82 0 5.8 0.2 6.1 5.6 10/02/2004 03:00:00 6.5 0.7 8 4.6 6.6 0.6 8 5.3 0.4 0 0.4 0.4 156 4 156 305 83 0 82 0 5.6 0.2 6.1 5.4 10/02/2004 03:10:00 5.4 0.8 7.6 3 5.7 0.6 7.2 3.4 0.4 0 0.4 0.4 157 6 156 305 83 0 82 0 5.5 0.2 6.1 5.2 10/02/2004 03:20:00 4.2 0.8 7.2 2.3 5 0.6 7.2 3.4 0.4 0 0.4 0.4 170 9 174 305 82 0 82 0 5.3 0 5.9 5.2 10/02/2004 03:30:00 4.7 0.7 6.5 2.6 5.6 0.6 7.2 4.2 0.4 0 0.4 0.4 164 7 162 305 81 1 80 0 5.5 0.2 6.1 5.4 10/02/2004 03:40:00 5.9 1 8 3.4 5.9 0.8 7.6 3.8 0.4 0 0.4 0.4 153 5 151 305 79 0 79 0 5.7 0.2 6.1 5.6 10/02/2004 03:50:00 5.8 1.2 8.4 3.4 6.5 0.6 7.6 4.6 0.4 0 0.4 0.4 159 5 154 305 79 0 79 0 5.7 0.2 6.1 5.6 10/02/2004 04:00:00 4.8 0.8 7.6 3 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 168 5 181 305 79 0 79 0 5.8 0.2 6.4 5.6 10/02/2004 04:10:00 6.2 1 8.8 4.2 7.9 0.6 9.5 5.7 0.4 0 0.4 0.4 174 6 181 305 79 0 79 0 6.1 0.2 6.7 5.9 10/02/2004 04:20:00 6.1 1 8.4 4.2 7.9 0.6 9.9 6.1 0.4 0 0.4 0.4 173 6 183 305 79 0 79 0 6.2 0.2 6.7 5.9 10/02/2004 04:30:00 5.9 1 8 3.4 7.6 0.7 9.5 5.7 0.4 0 0.4 0.4 174 5 174 305 79 0 79 0 6.2 0.2 6.7 5.9 10/02/2004 04:40:00 6.5 1.1 9.9 3.4 7.6 0.9 10.3 5.3 0.4 0 0.4 0.4 178 6 179 305 79 0 79 0 6.1 0.2 6.9 5.6 10/02/2004 04:50:00 6 1 8.4 3.8 8 0.7 9.9 5.3 0.4 0 0.4 0.4 170 6 177 305 79 0 78 0 6 0.3 6.9 5.6 10/02/2004 05:00:00 6.7 1.2 9.1 3.8 8 0.6 9.5 6.1 0.4 0 0.4 0.4 177 5 184 305 78 0 79 0 6 0.2 6.4 5.9 10/02/2004 05:10:00 6.3 1.1 8.8 3 7.1 0.8 9.1 4.9 0.4 0 0.4 0.4 179 5 181 305 78 0 78 0 6.1 0.2 6.7 5.9 10/02/2004 05:20:00 5.1 1.1 8.4 2.6 5.9 1.1 9.1 3.8 0.4 0 0.4 0.4 164 9 181 305 78 0 78 0 6 0.3 6.7 5.4 10/02/2004 05:30:00 4.1 0.8 6.5 2.6 5.3 0.5 6.8 3.8 0.4 0 0.4 0.4 167 7 181 305 82 1 82 0 5.5 0.1 5.9 5.4 10/02/2004 05:40:00 5 1.1 8 2.6 6.5 0.8 8.4 4.2 0.4 0 0.4 0.4 174 6 181 305 82 0 82 0 5.7 0.2 6.4 5.4 10/02/2004 05:50:00 5.5 1.3 8.8 2.6 6.4 0.8 8.4 4.6 0.4 0 0.4 0.4 178 6 183 305 81 0 82 0 5.8 0 6.4 5.6 10/02/2004 06:00:00 5.9 1.2 8.8 3.4 6.9 0.6 8.8 5.3 0.4 0 0.4 0.4 177 6 184 305 81 0 81 0 6 0.2 6.4 5.9 10/02/2004 06:10:00 6.3 0.9 8.4 3.4 6.5 0.6 8 4.6 0.4 0 0.4 0.4 182 5 174 305 80 0 80 0 5.8 0.2 6.4 5.6 10/02/2004 06:20:00 5.8 1 7.6 2.6 6.5 0.8 8 3.8 0.4 0 0.4 0.4 179 5 184 305 79 0 79 0 5.7 0.2 6.1 5.6 10/02/2004 06:30:00 5.7 0.8 7.2 3 6.3 0.7 7.6 3.8 0.4 0 0.4 0.4 180 5 186 305 79 0 79 0 5.8 0.1 6.4 5.6 10/02/2004 06:40:00 5.4 0.9 7.6 3 6.2 0.7 8 4.2 0.4 0 0.4 0.4 180 5 179 305 78 0 78 0 5.8 0.2 6.4 5.6 10/02/2004 06:50:00 4.6 1 7.2 2.6 5.3 0.8 7.2 3 0.4 0 0.4 0.4 179 7 186 305 77 0 80 0 5.6 0.2 6.1 5.4 10/02/2004 07:00:00 5 0.8 6.5 2.3 5.4 0.7 6.8 3.4 0.4 0 0.4 0.4 182 6 181 305 77 0 77 0 5.3 0.2 5.9 4.9 10/02/2004 07:10:00 5.6 0.5 6.8 3.8 6 0.4 7.2 4.6 0.4 0 0.4 0.4 183 3 180 305 76 0 77 0 5.3 0.1 5.9 5.2 10/02/2004 07:20:00 5.5 0.6 6.8 3 5.8 0.5 7.2 4.6 0.4 0 0.4 0.4 182 4 177 305 76 0 76 0 5.3 0.1 5.9 4.9 10/02/2004 07:30:00 4.5 1 6.1 1.9 5.1 0.7 6.5 2.6 0.4 0 0.4 0.4 180 5 184 305 76 0 76 0 5.4 0.1 5.9 5.2 10/02/2004 07:40:00 4.7 0.9 6.8 2.3 5.3 0.7 6.8 3.4 0.4 0 0.4 0.4 181 4 190 305 76 0 76 0 5.5 0.1 5.9 5.4 10/02/2004 07:50:00 5.4 0.7 7.2 2.6 5.7 0.5 7.6 4.6 0.4 0 0.4 0.4 182 4 183 305 75 0 76 0 5.5 0.2 5.9 5.4 10/02/2004 08:00:00 5.2 0.6 6.5 3 5.5 0.4 6.5 4.2 0.4 0 0.4 0.4 182 3 188 305 75 0 75 0 5.4 0.1 5.9 5.2 10/02/2004 08:10:00 4.3 1 6.8 2.3 5.4 0.6 7.2 4.2 0.4 0 0.4 0.4 175 6 181 305 75 0 75 0 5.5 0.2 6.1 5.2 10/02/2004 08:20:00 3.6 0.9 6.5 1.9 4.9 0.6 6.8 3 0.4 0 0.4 0.4 173 7 184 305 75 0 75 0 5.6 0.2 6.1 5.4 10/02/2004 08:30:00 4.9 1 7.2 2.3 5.7 0.7 7.6 4.2 0.4 0 0.4 0.4 179 7 177 305 74 0 75 0 5.5 0.1 6.1 5.4 10/02/2004 08:40:00 4.7 1.1 7.6 2.6 5.7 0.7 7.2 4.2 0.4 0 0.4 0.4 178 8 183 305 74 0 74 0 5.6 0.2 6.1 5.4 10/02/2004 08:50:00 5.5 0.8 7.2 2.6 6 0.6 7.2 4.6 0.4 0 0.4 0.4 180 5 176 305 74 0 74 0 5.6 0.2 6.1 5.4 10/02/2004 09:00:00 5.6 0.8 6.8 3 6.1 0.5 7.2 4.9 0.4 0 0.4 0.4 181 5 186 305 74 0 74 0 5.5 0.2 5.9 5.4 10/02/2004 09:10:00 5.1 1.1 7.2 2.3 6 0.8 8 4.2 0.4 0 0.4 0.4 177 5 174 305 74 0 74 0 5.6 0.2 6.1 5.4 10/02/2004 09:20:00 5.4 1.1 8 2.6 6.2 0.8 8 3.4 0.4 0 0.4 0.4 177 7 189 305 74 0 74 0 5.5 0.2 6.1 5.4 10/02/2004 09:30:00 5.6 1.2 8.4 3 6.6 0.6 8.4 4.9 0.4 0 0.4 0.4 178 8 189 305 74 0 74 0 5.6 0.2 6.1 5.4 10/02/2004 09:40:00 5.5 1.1 7.6 2.6 6.2 0.7 7.6 4.6 0.4 0 0.4 0.4 179 8 182 305 74 0 75 0 5.5 0.2 6.1 5.4 10/02/2004 09:50:00 5 1.1 6.8 2.6 6 0.6 7.6 4.6 0.4 0 0.4 0.4 176 8 184 305 75 0 75 0 5.5 0.1 6.1 5.4 10/02/2004 10:00:00 4.4 0.9 6.5 2.3 5.8 0.6 7.6 4.6 0.4 0 0.4 0.4 172 7 183 305 75 0 75 0 5.6 0.2 6.1 5.4 10/02/2004 10:10:00 4.2 0.8 6.1 1.9 5.1 0.5 6.1 3.4 0.4 0 0.4 0.4 164 8 155 305 74 0 77 0 5.5 0.1 6.1 5.4 10/02/2004 10:20:00 4.2 0.8 5.7 2.3 4.9 0.6 6.5 3 0.4 0 0.4 0.4 160 8 155 305 73 0 74 0 5.5 0.2 5.9 5.4 10/02/2004 10:30:00 4.1 0.6 5.7 2.3 4.5 0.6 6.1 3 0.4 0 0.4 0.4 157 8 158 305 73 0 73 0 5.4 0.1 5.9 5.4 10/02/2004 10:40:00 3.7 0.8 6.5 1.9 4.7 0.7 7.2 3 0.4 0 0.4 0.4 163 8 159 305 72 0 73 0 5.6 0.2 5.9 5.4 10/02/2004 10:50:00 3 0.9 5.7 1.1 3.7 0.7 5.7 1.9 0.4 0 0.4 0.4 161 10 186 305 71 0 71 0 5.6 0.2 5.9 5.4 10/02/2004 11:00:00 3.4 0.9 5.3 1.5 4.4 0.7 6.1 2.6 0.4 0 0.4 0.4 164 8 153 305 70 0 70 0 5.6 0.2 5.9 5.4 10/02/2004 11:10:00 3.6 0.8 6.1 1.9 4.9 0.6 7.2 3.8 0.4 0 0.4 0.4 166 7 158 305 69 0 69 0 5.6 0.2 6.1 5.4 10/02/2004 11:20:00 3.7 0.8 5.7 2.3 5.3 0.4 6.5 4.2 0.4 0 0.4 0.4 172 6 179 305 68 0 69 0 5.9 0.1 6.4 5.6 10/02/2004 11:30:00 4.3 0.9 6.5 2.3 5.8 0.8 7.6 4.2 0.4 0 0.4 0.4 168 7 161 305 67 0 67 0 5.8 0 6.4 5.6 10/02/2004 11:40:00 4.1 0.9 6.5 2.3 5.4 0.7 7.6 3.4 0.4 0 0.4 0.4 168 7 168 305 67 0 67 0 6.1 0.2 6.4 5.9 10/02/2004 11:50:00 3.9 0.8 6.5 2.3 5 0.7 6.8 2.6 0.4 0 0.4 0.4 169 8 181 305 67 1 66 0 6.1 0.1 6.7 5.9 10/02/2004 12:00:00 3.6 0.9 6.1 1.5 4.4 0.6 5.7 2.6 0.4 0 0.4 0.4 163 11 151 305 68 0 68 0 6.1 0.1 6.4 5.9 10/02/2004 12:10:00 3.4 0.8 5.7 1.5 3.9 0.7 6.5 2.6 0.4 0 0.4 0.4 158 14 151 305 69 0 68 0 6.3 0 6.9 6.1 10/02/2004 12:20:00 3.8 1 6.1 1.5 4.1 0.8 6.5 2.3 0.4 0 0.4 0.4 148 11 147 305 67 2 69 0 6.5 0 6.9 6.1 10/02/2004 12:30:00 3.7 1 6.5 1.9 4 0.8 6.1 1.9 0.4 0 0.4 0.4 156 16 144 305 59 6 66 0 6.5 0.1 7.2 6.4 10/02/2004 12:40:00 3.5 1.1 6.1 1.1 3.9 1 6.5 1.9 0.4 0 0.4 0.4 155 17 137 305 49 1 51 0 6.3 0 6.9 6.1 10/02/2004 12:50:00 4.8 1 6.8 3 4.7 0.9 6.8 2.6 0.4 0 0.4 0.4 143 11 146 305 50 0 50 0 6.3 0 6.9 6.1 10/02/2004 13:00:00 4.9 0.8 7.2 3 5 0.7 6.8 2.3 0.4 0 0.4 0.4 142 11 141 305 62 6 68 0 6.7 0.2 7.4 6.4 10/02/2004 13:10:00 4.1 1.2 6.8 1.5 4.5 1 7.2 2.3 0.4 0 0.4 0.4 155 14 142 305 77 17 68 0 7 0.1 7.7 6.9 10/02/2004 13:20:00 5.4 1 7.2 1.9 5.5 0.8 7.2 3.4 0.4 0 0.4 0.4 150 10 140 305 106 2 109 0 6.6 0.3 7.4 6.1 10/02/2004 13:30:00 4.8 0.8 6.5 2.6 5.1 0.7 6.8 3.4 0.4 0 0.4 0.4 150 11 136 305 102 1 103 0 6.3 0.1 6.9 5.9 10/02/2004 13:40:00 4.6 0.8 6.5 2.6 5 0.6 6.8 3.4 0.4 0 0.4 0.4 154 9 156 305 94 7 99 0 6.3 0.1 6.9 6.1 10/02/2004 13:50:00 4.9 0.7 6.5 2.6 4.9 0.6 6.8 3.4 0.4 0 0.4 0.4 147 9 147 305 76 3 79 0 6.2 0.1 6.9 5.9 10/02/2004 14:00:00 5.4 0.5 6.8 3.8 5.5 0.6 6.8 3.8 0.4 0 0.4 0.4 139 7 135 305 72 2 73 0 6 0.1 6.4 5.9 10/02/2004 14:10:00 5.5 0.7 7.2 4.2 5.5 0.7 7.2 3.8 0.4 0 0.4 0.4 141 8 156 305 66 1 66 0 6.1 0.1 6.4 5.9 10/02/2004 14:20:00 4.1 1.2 6.8 1.9 4.8 0.9 6.8 3 0.4 0 0.4 0.4 163 15 136 305 87 7 67 0 6 0.1 6.4 5.9 10/02/2004 14:30:00 3.5 0.8 5.7 1.9 4.2 0.6 5.7 2.6 0.4 0 0.4 0.4 161 10 155 305 66 6 61 0 6.1 0.1 6.4 5.9 10/02/2004 14:40:00 3 0.6 4.2 1.5 4.2 0.5 5.3 2.6 0.4 0 0.4 0.4 169 8 153 305 47 0 47 0 6.1 0.1 6.4 5.9 10/02/2004 14:50:00 3.4 0.8 5.3 1.1 3.9 0.6 5.7 2.3 0.4 0 0.4 0.4 157 12 143 305 48 0 48 0 6.1 0.1 6.4 5.9 10/02/2004 15:00:00 3.7 1.1 6.1 1.1 4 0.9 6.1 1.9 0.4 0 0.4 0.4 155 11 152 305 49 0 49 0 6 0.1 6.4 5.9 10/02/2004 15:10:00 2.8 0.7 4.6 1.5 3.4 0.6 5.3 1.9 0.4 0 0.4 0.4 181 15 191 305 48 1 49 0 6 0 6.4 5.6 10/02/2004 15:20:00 2.8 0.8 4.9 0.7 3.6 0.6 5.3 2.3 0.4 0 0.4 0.4 177 14 205 305 46 1 47 0 5.8 0 6.1 5.6 10/02/2004 15:30:00 3 0.7 4.6 1.5 3.6 0.5 4.9 2.3 0.4 0 0.4 0.4 171 16 187 305 42 1 44 0 5.8 0.1 6.1 5.6 10/02/2004 15:40:00 4.5 0.6 5.7 1.9 4.7 0.5 5.7 2.3 0.4 0 0.4 0.4 152 5 151 305 37 2 39 0 5.7 0 6.1 5.6 10/02/2004 15:50:00 3.8 0.6 5.3 1.9 4 0.5 5.3 2.6 0.4 0 0.4 0.4 143 9 141 305 28 3 26 0 5.7 0 6.1 5.6 10/02/2004 16:00:00 4.3 0.6 5.7 2.3 4.4 0.6 5.7 2.6 0.4 0 0.4 0.4 142 8 156 305 19 2 19 0 5.6 0.1 6.1 5.6 10/02/2004 16:10:00 4.2 0.5 5.7 3 4.4 0.5 5.7 3.4 0.4 0 0.4 0.4 148 7 155 305 14 1 16 0 5.6 0.1 5.9 5.4 10/02/2004 16:20:00 4.7 0.6 6.1 3 4.8 0.6 6.1 3.4 0.4 0 0.4 0.4 144 8 140 305 12 1 11 0 5.5 0.1 5.9 5.4 10/02/2004 16:30:00 4.9 0.5 6.1 3 5 0.5 6.1 3.4 0.4 0 0.4 0.4 135 5 133 305 10 0 10 0 5.5 0.1 5.9 5.4 10/02/2004 16:40:00 5.5 0.6 7.2 4.2 5.6 0.5 7.2 4.6 0.4 0 0.4 0.4 142 11 151 305 9 0 9 0 5.5 0.1 5.9 5.4 10/02/2004 16:50:00 6.1 0.5 7.6 4.6 6.1 0.5 7.2 4.9 0.4 0 0.4 0.4 150 4 155 305 8 0 8 0 5.4 0 5.9 5.4 10/02/2004 17:00:00 5.6 0.6 7.2 3.8 5.6 0.6 7.2 4.2 0.4 0 0.4 0.4 148 7 145 305 7 0 7 0 5.5 0.1 5.9 5.4 10/02/2004 17:10:00 6.1 0.7 7.6 4.2 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 151 6 151 305 7 0 7 0 5.3 0.1 5.9 5.2 10/02/2004 17:20:00 5.4 1 7.2 2.6 5.8 0.7 7.2 3.8 0.4 0 0.4 0.4 154 8 152 305 6 0 6 0 5.3 0.1 5.9 5.2 10/02/2004 17:30:00 5.1 0.8 6.8 2.6 5.5 0.6 7.2 3.8 0.4 0 0.4 0.4 156 8 153 305 6 0 6 0 5.2 0.1 5.6 4.9 10/02/2004 17:40:00 4.3 0.7 6.1 2.6 5.3 0.6 6.5 3.8 0.4 0 0.4 0.4 163 7 156 305 5 0 5 0 5.1 0.2 5.6 4.9 10/02/2004 17:50:00 4.3 0.7 6.1 2.6 5.5 0.6 6.8 3.8 0.4 0 0.4 0.4 166 8 156 305 5 0 5 0 5 0.2 5.6 4.9 10/02/2004 18:00:00 4.4 0.8 6.5 2.3 5.2 0.6 6.8 3.4 0.4 0 0.4 0.4 161 7 153 305 5 0 5 0 5 0.1 5.4 4.9 10/02/2004 18:10:00 3.7 0.7 6.1 2.3 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 168 7 154 305 5 0 5 0 5 0.1 5.4 4.7 10/02/2004 18:20:00 4.4 1 6.1 2.3 5.2 0.6 6.5 3.8 0.4 0 0.4 0.4 178 6 182 305 5 0 5 0 4.9 0.2 5.4 4.4 10/02/2004 18:30:00 3.8 0.7 5.7 2.3 5.3 0.6 6.5 3.4 0.4 0 0.4 0.4 171 6 182 305 5 0 5 0 4.7 0.2 5.2 4.4 10/02/2004 18:40:00 3.9 0.7 5.7 2.3 5.2 0.5 6.5 3.8 0.4 0 0.4 0.4 165 5 161 305 4 0 4 0 4.5 0.2 4.9 4.4 10/02/2004 18:50:00 3.4 0.7 5.3 1.9 4.6 0.4 5.3 3.4 0.4 0 0.4 0.4 164 5 152 305 4 0 4 0 4.4 0.1 4.9 4.2 10/02/2004 19:00:00 3.2 0.6 5.7 1.9 5 0.5 6.1 3.4 0.4 0 0.4 0.4 169 4 161 305 4 0 4 0 4.2 0.1 4.7 4.2 10/02/2004 19:10:00 3 0.7 4.9 1.5 4.5 0.4 5.7 3.4 0.4 0 0.4 0.4 166 4 157 305 3 0 4 0 4.2 0.2 4.7 3.9 10/02/2004 19:20:00 2.3 0.6 3.8 0.7 3.5 0.4 4.6 2.6 0.4 0 0.4 0.4 166 11 160 305 3 0 4 0 4.2 0.2 4.7 3.9 10/02/2004 19:30:00 1.9 0.7 3.4 0.4 2.9 0.7 4.6 0.7 0.4 0 0.4 0.4 167 9 155 305 4 0 4 0 4.1 0.2 4.7 3.9 10/02/2004 19:40:00 1.8 1.1 4.6 0.4 2.8 1.2 4.9 0.4 0.4 0 0.4 0.4 169 11 182 305 4 0 4 0 4 0.2 4.4 3.9 10/02/2004 19:50:00 2.7 0.6 4.2 1.1 4 0.6 5.3 2.6 0.4 0 0.4 0.4 172 6 179 305 4 0 4 0 4 0.2 4.4 3.7 10/02/2004 20:00:00 2.5 0.9 4.6 0.4 3.1 0.8 4.9 1.5 0.4 0 0.4 0.4 160 12 150 305 4 0 4 0 3.9 0.2 4.4 3.7 10/02/2004 20:10:00 1.5 1 3.8 0.4 2.1 0.8 3.8 0.4 0.4 0 0.4 0.4 149 16 135 305 4 0 4 0 3.9 0.1 4.4 3.7 10/02/2004 20:20:00 1.1 0.8 3.4 0.4 1.7 0.7 3.4 0.4 0.4 0 0.4 0.4 158 17 156 305 4 0 4 0 3.9 0.1 4.4 3.7 10/02/2004 20:30:00 1.8 0.8 3.8 0.4 2.3 0.6 3.8 1.1 0.4 0 0.4 0.4 138 15 125 305 4 0 4 0 3.9 0.2 4.4 3.7 10/02/2004 20:40:00 1.8 0.6 3.4 0.4 2.3 0.5 3.8 1.1 0.4 0 0.4 0.4 120 15 129 305 5 0 5 0 3.9 0.2 4.4 3.7 10/02/2004 20:50:00 1.6 1.1 3.8 0.4 2.2 0.8 4.2 0.7 0.4 0 0.4 0.4 142 12 129 305 4 0 5 0 3.9 0.2 4.4 3.7 10/02/2004 21:00:00 2.7 1 4.6 0.4 3 0.7 4.6 1.5 0.4 0 0.4 0.4 131 17 116 305 5 0 4 0 4 0.2 4.4 3.7 10/02/2004 21:10:00 3.1 1.2 5.7 0.4 3.4 1.1 6.5 1.1 0.4 0 0.4 0.4 139 12 147 305 4 0 4 0 4 0.1 4.4 3.7 10/02/2004 21:20:00 2.3 0.8 4.6 0.4 2.7 0.6 4.6 0.7 0.4 0 0.4 0.4 127 15 119 305 5 0 5 0 4 0.1 4.4 3.9 10/02/2004 21:30:00 2.3 1 4.6 0.4 2.6 0.8 4.6 0.7 0.4 0 0.4 0.4 132 15 122 305 5 0 5 0 4 0.1 4.4 3.9 10/02/2004 21:40:00 2.2 0.7 4.9 0.4 2.8 0.6 4.6 1.1 0.4 0 0.4 0.4 153 20 153 305 4 0 4 0 4 0.1 4.4 3.9 10/02/2004 21:50:00 2.1 0.8 4.9 0.4 2.6 0.6 4.9 1.5 0.4 0 0.4 0.4 146 12 129 305 4 0 5 0 4 0.1 4.4 3.9 10/02/2004 22:00:00 3.2 0.9 5.3 1.1 3.6 0.7 4.9 2.3 0.4 0 0.4 0.4 148 17 153 305 4 0 4 0 4 0.1 4.4 3.7 10/02/2004 22:10:00 2.7 0.7 3.8 0.7 3.2 0.6 4.6 1.1 0.4 0 0.4 0.4 161 21 151 305 4 0 4 0 3.9 0.1 4.4 3.7 10/02/2004 22:20:00 2.9 0.5 3.8 0.7 3.3 0.4 4.2 2.3 0.4 0 0.4 0.4 183 6 187 305 4 0 4 0 3.6 0.1 4.2 3.4 10/02/2004 22:30:00 1.7 0.5 3 0.4 2.3 0.4 3 1.1 0.4 0 0.4 0.4 184 5 183 305 5 0 5 0 3.6 0.1 3.9 3.4 10/02/2004 22:40:00 1.4 0.5 2.6 0.4 2.1 0.4 3 1.1 0.4 0 0.4 0.4 187 10 199 305 5 0 5 0 3.5 0.1 3.9 3.4 10/02/2004 22:50:00 1.2 0.5 2.3 0.4 2 0.4 3 1.1 0.4 0 0.4 0.4 182 9 192 305 6 0 6 0 3.6 0 3.9 3.4 10/02/2004 23:00:00 1 0.5 2.3 0.4 1.8 0.5 3 0.7 0.4 0 0.4 0.4 168 11 158 305 6 0 6 0 3.6 0 4.2 3.4 10/02/2004 23:10:00 1.2 1 3.8 0.4 2 0.7 4.2 0.7 0.4 0 0.4 0.4 177 11 190 305 6 0 6 0 3.6 0 4.2 3.4 10/02/2004 23:20:00 2.1 0.6 3.8 0.7 2.9 0.5 4.2 1.9 0.4 0 0.4 0.4 172 11 136 305 6 0 6 0 3.5 0 3.9 3.4 10/02/2004 23:30:00 1.3 0.6 3 0.4 2.2 0.5 3.4 1.1 0.4 0 0.4 0.4 174 13 184 305 6 0 6 0 3.5 0 3.7 3.4 10/02/2004 23:40:00 0.7 0.5 2.3 0.4 1.7 0.4 2.6 0.7 0.4 0 0.4 0.4 164 11 154 305 7 0 6 0 3.5 0.1 3.9 3.4 10/02/2004 23:50:00 2.3 0.7 3.8 0.4 2.8 0.4 3.8 1.9 0.4 0 0.4 0.4 150 11 164 305 7 0 7 0 3.5 0 3.9 3.4 10/03/2004 00:00:00 2.1 0.8 4.2 0.4 2.7 0.6 4.6 1.5 0.4 0 0.4 0.4 153 15 142 305 6 0 6 0 3.6 0 4.2 3.4 10/03/2004 00:10:00 2.8 0.8 4.6 1.1 3.3 0.6 4.6 1.9 0.4 0 0.4 0.4 150 10 153 305 6 0 6 0 3.5 0 3.9 3.4 10/03/2004 00:20:00 3.3 0.7 4.9 1.1 3.6 0.6 5.3 2.3 0.4 0 0.4 0.4 142 13 109 305 5 0 5 0 3.5 0 3.9 3.4 10/03/2004 00:30:00 3.1 0.8 5.7 1.5 3.3 0.7 6.1 1.9 0.4 0 0.4 0.4 134 12 138 305 5 0 5 0 3.5 0 3.9 3.4 10/03/2004 00:40:00 1.9 0.7 4.2 0.4 2.4 0.5 3.8 0.7 0.4 0 0.4 0.4 144 16 119 305 5 0 5 0 3.5 0 3.7 3.4 10/03/2004 00:50:00 2.5 0.9 4.6 0.4 2.7 0.6 4.6 1.1 0.4 0 0.4 0.4 137 15 127 305 5 0 5 0 3.4 0.1 3.7 3.4 10/03/2004 01:00:00 2.7 0.7 4.2 0.4 3 0.5 4.6 1.5 0.4 0 0.4 0.4 127 17 141 305 5 0 4 0 3.5 0 3.9 3.4 10/03/2004 01:10:00 2.3 0.6 3.8 0.4 2.8 0.6 4.2 1.1 0.4 0 0.4 0.4 148 20 156 305 4 0 4 0 3.5 0 3.9 3.4 10/03/2004 01:20:00 2.8 0.8 4.9 1.1 3.1 0.7 5.3 1.9 0.4 0 0.4 0.4 137 11 151 305 4 0 4 0 3.4 0.1 3.7 3.4 10/03/2004 01:30:00 1.9 0.9 4.2 0.4 2.4 0.8 4.2 0.7 0.4 0 0.4 0.4 122 15 125 305 4 0 4 0 3.4 0.1 3.7 3.2 10/03/2004 01:40:00 2.6 1 4.9 0.4 2.9 0.8 5.3 0.7 0.4 0 0.4 0.4 118 19 110 305 4 0 4 0 3.3 0 3.7 3.2 10/03/2004 01:50:00 3 0.9 5.7 1.5 3.2 0.7 4.9 1.9 0.4 0 0.4 0.4 118 15 94 305 4 0 4 0 3.3 0 3.7 3.2 10/03/2004 02:00:00 3 0.8 4.9 1.1 3.1 0.7 4.9 1.1 0.4 0 0.4 0.4 99 24 106 305 4 0 4 0 3.3 0 3.7 3.2 10/03/2004 02:10:00 1.7 1 3.8 0.4 2.2 0.8 4.6 0.4 0.4 0 0.4 0.4 123 23 80 305 4 0 4 0 3.3 0 3.7 3.2 10/03/2004 02:20:00 4.3 0.9 6.8 1.5 4.3 1 7.2 2.3 0.4 0 0.4 0.4 132 11 149 305 4 0 4 0 3.3 0 3.7 3.2 10/03/2004 02:30:00 3.6 0.7 4.9 1.1 3.7 0.6 5.7 2.3 0.4 0 0.4 0.4 140 10 133 305 4 0 4 0 3.3 0 3.7 3.2 10/03/2004 02:40:00 3.1 0.7 4.6 1.1 3.2 0.6 4.9 1.9 0.4 0 0.4 0.4 140 13 145 305 4 0 4 0 3.1 0 3.4 3.2 10/03/2004 02:50:00 2.9 0.8 4.6 1.1 3.1 0.6 4.6 1.5 0.4 0 0.4 0.4 142 12 133 305 4 0 4 0 3.1 0 3.4 3.2 10/03/2004 03:00:00 3.9 1.2 7.2 1.5 4.2 1.1 6.8 2.3 0.4 0 0.4 0.4 139 15 142 305 4 0 4 0 3.2 0 3.7 3.2 10/03/2004 03:10:00 2.3 1.1 4.6 0.4 2.8 0.8 4.9 0.7 0.4 0 0.4 0.4 138 18 144 305 4 0 4 0 3.3 0 3.4 3.2 10/03/2004 03:20:00 2.2 0.9 5.3 0.4 2.9 0.7 4.9 0.7 0.4 0 0.4 0.4 160 22 147 305 4 0 5 0 3.3 0.1 3.7 3.2 10/03/2004 03:30:00 2.4 0.8 4.6 0.7 3.1 0.6 4.6 1.5 0.4 0 0.4 0.4 155 12 147 305 5 0 5 0 3.3 0 3.7 3.2 10/03/2004 03:40:00 3.6 1.2 6.5 1.1 3.9 1.1 6.5 1.9 0.4 0 0.4 0.4 152 13 152 305 5 0 5 0 3.2 0 3.7 2.9 10/03/2004 03:50:00 3.1 0.9 5.3 0.7 3.6 0.7 5.3 1.9 0.4 0 0.4 0.4 155 13 140 305 5 0 5 0 3.1 0 3.4 2.9 10/03/2004 04:00:00 1.8 0.8 3.8 0.4 2.6 0.5 3.8 1.5 0.4 0 0.4 0.4 162 17 135 305 5 0 5 0 3.1 0 3.4 2.9 10/03/2004 04:10:00 2.1 0.7 3.8 0.4 3 0.5 4.6 1.5 0.4 0 0.4 0.4 176 9 177 305 5 0 5 0 3.1 0 3.4 2.9 10/03/2004 04:20:00 1.2 0.6 3 0.4 2.2 0.5 3.8 1.1 0.4 0 0.4 0.4 177 11 180 305 5 0 5 0 3 0.1 3.4 2.9 10/03/2004 04:30:00 1 0.7 4.6 0.4 2.1 0.5 4.2 0.7 0.4 0 0.4 0.4 165 10 144 305 5 0 6 0 2.9 0.1 3.2 2.7 10/03/2004 04:40:00 1.2 0.8 3.8 0.4 1.9 0.7 4.2 0.4 0.4 0 0.4 0.4 156 18 139 305 6 0 5 0 2.9 0 3.4 2.9 10/03/2004 04:50:00 2.9 1.2 6.1 0.4 3.1 1.1 5.7 0.7 0.4 0 0.4 0.4 110 28 134 305 6 0 6 0 3.1 0.2 3.7 2.9 10/03/2004 05:00:00 2.5 1.7 6.1 0.4 2.8 1.5 6.8 0.4 0.4 0 0.4 0.4 94 28 56 305 6 0 6 0 3.5 0.1 4.2 3.4 10/03/2004 05:10:00 2.2 1.1 4.9 0.4 2.6 0.8 4.6 0.4 0.4 0 0.4 0.4 117 28 79 305 5 0 6 0 3.6 0.2 4.2 3.4 10/03/2004 05:20:00 3.2 1 5.7 0.7 3.3 0.9 5.7 1.1 0.4 0 0.4 0.4 96 17 89 305 6 0 6 0 3.5 0.1 4.2 3.2 10/03/2004 05:30:00 3.5 1.6 8.8 0.4 3.6 1.3 8.4 1.5 0.4 0 0.4 0.4 95 41 58 305 6 0 6 0 3.6 0 4.2 3.4 10/03/2004 05:40:00 5.4 1.7 9.5 1.5 5.3 1.7 9.1 1.9 0.4 0 0.4 0.4 77 16 82 305 6 0 6 0 3.7 0 3.9 3.4 10/03/2004 05:50:00 6.4 1.8 9.9 1.1 6.3 1.7 9.9 1.9 0.4 0 0.4 0.4 76 14 56 305 6 0 6 0 3.6 0 3.7 3.4 10/03/2004 06:00:00 6.6 1.2 9.9 4.2 6.5 1.2 9.9 4.2 0.4 0 0.4 0.4 76 11 73 305 6 0 6 0 3.6 0 4.2 3.4 10/03/2004 06:10:00 6.3 1.1 8.8 3.4 6.2 1.1 8.4 3.4 0.4 0 0.4 0.4 77 9 64 305 6 0 6 0 3.6 0 3.7 3.4 10/03/2004 06:20:00 6.3 1.2 11.8 4.2 6.1 1.2 11.5 3.4 0.4 0 0.4 0.4 72 12 81 305 6 0 6 0 3.6 0 3.7 3.4 10/03/2004 06:30:00 6.9 1.1 10.3 4.6 6.7 1.2 10.7 3.8 0.4 0 0.4 0.4 76 12 82 305 6 0 6 0 3.6 0 3.7 3.7 10/03/2004 06:40:00 7.1 0.9 9.9 4.9 6.9 0.8 9.1 4.6 0.4 0 0.4 0.4 73 8 72 305 6 0 6 0 3.7 0 4.2 3.4 10/03/2004 06:50:00 7.6 0.9 10.3 4.2 7.4 0.8 9.9 4.6 0.4 0 0.4 0.4 75 8 72 305 6 0 6 0 3.6 0 3.7 3.4 10/03/2004 07:00:00 6.3 1.2 11.1 4.2 6.2 1.1 10.3 4.2 0.4 0 0.4 0.4 75 12 77 305 6 0 6 0 3.4 0 3.9 3.4 10/03/2004 07:10:00 6.3 1.6 9.9 2.6 6.4 1.5 9.9 2.6 0.4 0 0.4 0.4 76 12 69 305 5 0 6 0 3.6 0 3.9 3.4 10/03/2004 07:20:00 7.2 1.1 11.8 3.4 7.1 1 11.1 4.2 0.4 0 0.4 0.4 74 9 71 305 5 0 5 0 3.6 0 3.7 3.4 10/03/2004 07:30:00 7.5 1 10.7 5.3 7.3 1 9.9 4.9 0.4 0 0.4 0.4 77 9 68 305 5 0 5 0 3.6 0 3.7 3.4 10/03/2004 07:40:00 6.9 0.8 9.1 4.6 6.7 0.7 8.8 4.9 0.4 0 0.4 0.4 74 8 81 305 5 0 5 0 3.6 0 3.7 3.4 10/03/2004 07:50:00 6.8 1 9.9 4.2 6.7 1 9.1 4.2 0.4 0 0.4 0.4 82 10 85 305 5 0 5 0 3.6 0 4.2 3.4 10/03/2004 08:00:00 7.6 1.1 9.5 4.9 7.5 1 9.9 4.9 0.4 0 0.4 0.4 72 7 67 305 6 0 6 0 3.6 0.1 4.2 3.4 10/03/2004 08:10:00 6.6 0.8 8.4 4.6 6.5 0.7 8.4 4.6 0.4 0 0.4 0.4 74 8 88 305 6 0 6 0 3.5 0 3.9 3.4 10/03/2004 08:20:00 7.3 0.9 9.5 4.9 7.1 0.8 9.5 4.9 0.4 0 0.4 0.4 72 7 71 305 7 0 7 0 3.4 0.1 3.9 3.2 10/03/2004 08:30:00 7.2 0.9 9.5 4.9 7.1 0.8 9.1 4.6 0.4 0 0.4 0.4 69 6 76 305 7 0 7 0 3.3 0.1 3.7 3.2 10/03/2004 08:40:00 7.7 0.8 9.9 5.3 7.5 0.8 9.5 5.3 0.4 0 0.4 0.4 68 8 70 305 8 0 8 0 3.3 0.1 3.7 3.2 10/03/2004 08:50:00 7.3 0.6 9.5 4.9 7.1 0.6 8.4 5.3 0.4 0 0.4 0.4 64 5 65 305 8 0 8 0 3.3 0.1 3.7 3.2 10/03/2004 09:00:00 7.5 0.7 9.9 5.7 7.3 0.8 9.5 5.3 0.4 0 0.4 0.4 65 6 53 305 8 0 8 0 3.3 0.1 3.7 3.2 10/03/2004 09:10:00 7.1 0.9 9.1 4.9 7 0.9 8.8 4.9 0.4 0 0.4 0.4 64 6 69 305 9 0 8 0 3.3 0.1 3.7 3.2 10/03/2004 09:20:00 6.9 0.8 8.8 5.3 6.9 0.7 8.8 5.3 0.4 0 0.4 0.4 61 8 50 305 9 0 9 0 3.3 0.1 3.7 2.9 10/03/2004 09:30:00 7.4 0.7 9.1 5.7 7.3 0.8 9.5 5.3 0.4 0 0.4 0.4 58 7 56 305 10 0 10 0 3.3 0 3.7 3.2 10/03/2004 09:40:00 7.5 0.8 8.8 5.3 7.3 0.7 8.8 4.9 0.4 0 0.4 0.4 61 5 58 305 11 0 11 0 3.3 0.1 3.7 3.2 10/03/2004 09:50:00 7.3 0.6 8.8 6.1 7.3 0.5 9.1 5.7 0.4 0 0.4 0.4 50 6 52 305 11 0 11 0 3.3 0 3.7 3.2 10/03/2004 10:00:00 6.2 1 8.4 4.2 6.3 0.9 8.4 4.6 0.4 0 0.4 0.4 46 5 51 305 11 0 11 0 3.1 0 3.7 2.9 10/03/2004 10:10:00 7.6 0.6 8.8 5.7 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 51 4 49 305 12 0 12 0 3.2 0 3.7 2.9 10/03/2004 10:20:00 7.3 0.7 8.8 5.3 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 45 4 44 305 13 0 12 0 3 0 3.7 2.9 10/03/2004 10:30:00 6.9 0.5 8 5.7 6.9 0.5 8.4 5.7 0.4 0 0.4 0.4 48 6 42 305 13 0 13 0 3.1 0 3.4 2.9 10/03/2004 10:40:00 7.6 0.8 9.5 5.7 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 50 5 56 305 14 0 15 0 3.3 0 3.7 3.2 10/03/2004 10:50:00 7.6 0.7 9.1 5.7 7.7 0.7 9.5 5.7 0.4 0 0.4 0.4 48 6 56 305 15 0 15 0 3.1 0 3.4 2.9 10/03/2004 11:00:00 7.5 0.6 9.1 6.1 7.6 0.6 9.1 5.7 0.4 0 0.4 0.4 48 6 52 305 15 0 15 0 3 0 3.4 2.9 10/03/2004 11:10:00 7.5 0.4 8.4 6.5 7.6 0.5 8.8 6.1 0.4 0 0.4 0.4 46 4 41 305 16 0 16 0 3.1 0 3.2 2.9 10/03/2004 11:20:00 7.5 0.6 8.8 5.7 7.6 0.6 8.8 5.7 0.4 0 0.4 0.4 46 4 42 305 17 0 17 0 3.1 0 3.2 2.9 10/03/2004 11:30:00 7.7 0.6 9.1 6.1 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 45 4 47 305 17 0 17 0 3.1 0 3.2 2.9 10/03/2004 11:40:00 8 0.6 9.5 6.5 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 45 4 51 305 17 0 17 0 3.1 0 3.2 2.9 10/03/2004 11:50:00 8.1 0.5 9.5 6.5 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 45 5 42 305 18 0 18 0 3.1 0 3.2 2.9 10/03/2004 12:00:00 8.6 0.5 9.9 6.8 8.6 0.6 10.3 6.8 0.4 0 0.4 0.4 41 5 38 305 18 0 18 0 3 0 3.7 2.9 10/03/2004 12:10:00 8.6 0.5 10.3 7.2 8.7 0.6 10.3 6.5 0.4 0 0.4 0.4 42 4 42 305 18 0 18 0 2.9 0.1 3.4 2.7 10/03/2004 12:20:00 9.4 0.5 10.7 7.6 9.6 0.6 11.1 7.6 0.4 0 0.4 0.4 41 4 40 305 18 0 18 0 2.7 0 3.2 2.5 10/03/2004 12:30:00 9.4 0.6 10.7 7.2 9.4 0.6 10.7 7.2 0.4 0 0.4 0.4 44 5 37 305 18 0 18 0 2.6 0 3.2 2.5 10/03/2004 12:40:00 9.8 0.5 11.1 8.4 10 0.6 12.2 8 0.4 0 0.4 0.4 40 4 42 305 18 0 18 0 2.6 0.1 3.2 2.2 10/03/2004 12:50:00 9.2 0.6 10.7 7.6 9.4 0.6 10.7 7.2 0.4 0 0.4 0.4 39 6 43 305 18 0 18 0 2.5 0.1 3.2 2.2 10/03/2004 13:00:00 8.6 0.7 10.3 6.8 8.8 0.7 10.3 6.8 0.4 0 0.4 0.4 33 5 38 305 17 0 18 0 2.5 0 2.9 2.2 10/03/2004 13:10:00 7.9 0.6 9.5 6.5 8.1 0.7 9.9 6.5 0.4 0 0.4 0.4 35 5 39 305 16 0 17 0 2.5 0 3.2 2.2 10/03/2004 13:20:00 7.3 0.5 8.8 6.1 7.4 0.5 8.8 5.3 0.4 0 0.4 0.4 31 5 36 305 15 0 15 0 2.7 0.1 3.2 2.5 10/03/2004 13:30:00 7.6 0.6 9.1 6.1 7.8 0.6 9.1 5.7 0.4 0 0.4 0.4 24 5 22 305 14 0 14 0 2.8 0.1 3.4 2.7 10/03/2004 13:40:00 7.9 0.5 9.1 6.5 8.1 0.5 9.5 6.5 0.4 0 0.4 0.4 23 5 30 305 13 0 13 0 2.8 0.1 3.2 2.5 10/03/2004 13:50:00 7.4 0.5 8.8 5.7 7.6 0.6 8.8 5.3 0.4 0 0.4 0.4 26 5 34 305 12 0 13 0 2.8 0.1 3.4 2.7 10/03/2004 14:00:00 7.2 0.4 8.4 5.7 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 27 4 33 305 12 0 12 0 2.8 0.1 3.2 2.7 10/03/2004 14:10:00 7.1 0.5 8.4 6.1 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 31 4 35 305 11 0 11 0 2.8 0.2 3.4 2.7 10/03/2004 14:20:00 6.9 0.5 8 5.7 7.2 0.5 8.4 5.3 0.4 0 0.4 0.4 27 4 30 305 11 0 11 0 2.8 0.2 3.4 2.7 10/03/2004 14:30:00 7.2 0.5 8.4 5.7 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 28 5 23 305 10 0 11 0 3 0.1 3.4 2.9 10/03/2004 14:40:00 6.9 0.6 8.4 5.3 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 28 5 31 305 10 0 10 0 3.1 0 3.7 2.9 10/03/2004 14:50:00 7.2 0.5 8.4 6.1 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 24 5 27 305 10 0 10 0 3.2 0 3.4 3.2 10/03/2004 15:00:00 7.7 0.5 9.1 6.5 8 0.6 9.1 6.1 0.4 0 0.4 0.4 25 5 26 305 10 0 10 0 3.2 0 3.4 3.2 10/03/2004 15:10:00 7.4 0.5 8.8 6.5 7.6 0.5 9.1 6.1 0.4 0 0.4 0.4 26 5 22 305 10 0 11 0 3.2 0 3.7 2.9 10/03/2004 15:20:00 7.1 0.6 9.1 5.3 7.4 0.6 9.1 5.7 0.4 0 0.4 0.4 24 6 23 305 11 0 11 0 3.1 0 3.4 2.9 10/03/2004 15:30:00 7.6 0.5 8.8 6.5 7.9 0.5 9.1 6.5 0.4 0 0.4 0.4 20 3 21 305 11 0 11 0 3.2 0 3.4 2.9 10/03/2004 15:40:00 7.7 0.5 8.8 6.1 8 0.6 9.1 6.5 0.4 0 0.4 0.4 20 4 23 305 10 0 10 0 3.3 0 3.4 3.2 10/03/2004 15:50:00 7.8 0.7 9.5 5.7 8 0.7 9.9 5.7 0.4 0 0.4 0.4 18 6 17 305 10 0 10 0 3.3 0 3.4 3.2 10/03/2004 16:00:00 7.7 0.6 9.1 6.1 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 26 4 21 305 10 0 10 0 3.3 0 3.7 3.2 10/03/2004 16:10:00 7.5 0.5 9.1 6.1 7.7 0.5 9.1 6.5 0.4 0 0.4 0.4 25 4 27 305 12 0 12 0 3.2 0 3.4 2.9 10/03/2004 16:20:00 7.3 0.5 8.8 6.1 7.5 0.5 8.8 5.7 0.4 0 0.4 0.4 25 4 29 305 13 0 13 0 3.1 0 3.4 2.9 10/03/2004 16:30:00 7.5 0.6 9.1 6.1 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 30 6 26 305 14 0 14 0 3.2 0 3.4 2.9 10/03/2004 16:40:00 7.7 0.5 9.1 6.5 7.9 0.5 8.8 6.5 0.4 0 0.4 0.4 36 4 31 305 16 0 15 0 3.3 0 3.7 3.2 10/03/2004 16:50:00 7.8 0.7 9.9 6.1 7.9 0.6 9.9 6.1 0.4 0 0.4 0.4 37 5 43 305 17 0 17 0 3.4 0 3.7 3.2 10/03/2004 17:00:00 8.7 0.5 10.3 7.2 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 41 4 42 305 17 0 17 0 3.6 0.2 4.2 3.4 10/03/2004 17:10:00 8.3 0.4 9.5 7.2 8.5 0.5 9.9 7.2 0.4 0 0.4 0.4 43 5 46 305 17 0 17 0 3.6 0 4.2 3.4 10/03/2004 17:20:00 8.3 0.5 9.5 6.8 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 40 6 51 305 17 0 17 0 3.7 0 4.2 3.4 10/03/2004 17:30:00 7.9 0.5 9.1 6.1 8 0.6 9.5 6.1 0.4 0 0.4 0.4 39 7 36 305 16 0 16 0 3.7 0.1 4.4 3.7 10/03/2004 17:40:00 7.5 0.8 9.1 4.9 7.7 0.8 9.1 5.3 0.4 0 0.4 0.4 35 8 50 305 15 0 15 0 3.6 0 4.2 3.4 10/03/2004 17:50:00 8 0.7 9.9 6.1 8.1 0.7 9.9 5.7 0.4 0 0.4 0.4 32 5 29 305 15 0 15 0 3.7 0 4.4 3.4 10/03/2004 18:00:00 7.6 0.9 9.9 5.7 7.7 1 9.9 5.3 0.4 0 0.4 0.4 42 8 30 305 15 0 15 0 3.8 0 4.4 3.7 10/03/2004 18:10:00 7.7 0.5 9.1 6.1 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 35 6 46 305 14 0 14 0 3.9 0.2 4.4 3.7 10/03/2004 18:20:00 7.7 0.9 9.5 5.3 7.9 1 9.5 5.3 0.4 0 0.4 0.4 36 6 36 305 14 0 14 0 3.8 0 4.4 3.4 10/03/2004 18:30:00 8.1 0.8 9.5 6.1 8.3 0.8 9.9 6.5 0.4 0 0.4 0.4 41 4 40 305 14 0 14 0 3.6 0.2 4.2 3.2 10/03/2004 18:40:00 7.1 0.6 8.4 5.7 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 32 5 33 305 13 0 14 0 3.6 0.1 4.2 3.2 10/03/2004 18:50:00 7 0.6 8.4 5.7 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 34 7 36 305 13 0 14 0 3.6 0.2 4.2 3.4 10/03/2004 19:00:00 6.5 0.7 7.6 4.6 6.7 0.7 8 4.9 0.4 0 0.4 0.4 38 10 27 305 13 0 13 0 3.4 0.2 4.2 3.2 10/03/2004 19:10:00 7.3 0.5 8.8 6.1 7.4 0.5 8.8 5.7 0.4 0 0.4 0.4 38 7 35 305 13 0 13 0 3.7 0 4.2 3.7 10/03/2004 19:20:00 8.3 0.7 9.9 6.1 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 31 5 32 305 12 0 12 0 3.7 0 3.9 3.4 10/03/2004 19:30:00 8.3 0.6 9.5 6.5 8.5 0.6 9.9 6.5 0.4 0 0.4 0.4 28 6 36 305 12 0 12 0 3.5 0 3.7 3.4 10/03/2004 19:40:00 8.4 0.7 10.3 6.5 8.6 0.7 10.3 6.5 0.4 0 0.4 0.4 23 6 24 305 12 0 12 0 3.4 0.1 4.2 3.2 10/03/2004 19:50:00 8.6 0.9 11.1 7.2 8.9 0.8 11.5 6.8 0.4 0 0.4 0.4 13 5 19 305 13 0 14 0 3.4 0.1 3.7 3.2 10/03/2004 20:00:00 9.4 0.8 11.5 6.8 9.6 0.8 11.5 6.8 0.4 0 0.4 0.4 14 4 19 305 14 0 14 0 3.4 0.1 3.9 3.2 10/03/2004 20:10:00 9.2 1.4 11.5 6.5 9.4 1.5 11.5 6.1 0.4 0 0.4 0.4 16 5 8 305 14 0 14 0 3.1 0.1 3.7 2.9 10/03/2004 20:20:00 9.3 0.6 10.7 7.2 9.5 0.8 11.1 7.2 0.4 0 0.4 0.4 14 5 21 305 15 0 15 0 3.2 0 3.7 3.2 10/03/2004 20:30:00 10 0.5 11.5 8.4 10.2 0.6 11.5 8.4 0.4 0 0.4 0.4 15 4 14 305 16 0 16 0 3.4 0.1 3.7 3.2 10/03/2004 20:40:00 9.9 0.5 11.1 8.8 10.2 0.5 11.5 8.8 0.4 0 0.4 0.4 13 3 13 305 15 0 16 0 3.3 0 3.7 3.2 10/03/2004 20:50:00 9.8 0.6 11.5 7.6 10 0.7 11.5 7.6 0.4 0 0.4 0.4 13 4 21 305 15 0 15 0 3.3 0 3.7 3.2 10/03/2004 21:00:00 9.7 0.6 11.5 8 9.8 0.7 11.8 7.6 0.4 0 0.4 0.4 16 4 21 305 15 0 15 0 3.3 0 3.7 3.2 10/03/2004 21:10:00 9.7 0.7 11.8 8 9.9 0.7 11.5 8 0.4 0 0.4 0.4 15 4 17 305 15 0 15 0 3.3 0 3.7 3.2 10/03/2004 21:20:00 9.5 0.5 10.7 7.6 9.8 0.6 11.5 8 0.4 0 0.4 0.4 14 4 18 305 15 0 15 0 3.3 0 3.7 3.2 10/03/2004 21:30:00 9.3 0.6 10.7 7.6 9.5 0.6 11.5 7.6 0.4 0 0.4 0.4 16 5 9 305 15 0 15 0 3.3 0.1 3.7 3.2 10/03/2004 21:40:00 9.6 0.6 11.1 7.6 9.8 0.6 11.5 7.6 0.4 0 0.4 0.4 21 4 21 305 15 0 15 0 3.3 0.1 3.7 3.2 10/03/2004 21:50:00 9.7 0.7 11.1 7.6 9.9 0.8 11.5 8 0.4 0 0.4 0.4 18 4 22 305 15 0 15 0 3.1 0.1 3.7 2.9 10/03/2004 22:00:00 9.4 0.7 11.5 7.6 9.6 0.8 12.2 7.2 0.4 0 0.4 0.4 17 5 25 305 15 0 16 0 2.9 0.1 3.4 2.7 10/03/2004 22:10:00 9.9 0.5 11.5 8.4 10.1 0.6 11.8 8.4 0.4 0 0.4 0.4 22 5 18 305 15 0 15 0 2.9 0.1 3.4 2.7 10/03/2004 22:20:00 10.3 0.8 12.2 8 10.5 0.9 12.6 8 0.4 0 0.4 0.4 25 5 22 305 16 0 16 0 2.6 0 3.2 2.5 10/03/2004 22:30:00 11.2 0.7 12.6 9.5 11.4 0.8 13 9.1 0.4 0 0.4 0.4 22 4 22 305 16 0 16 0 2.6 0 3.2 2.5 10/03/2004 22:40:00 11.4 0.7 12.6 9.5 11.6 0.8 13 9.1 0.4 0 0.4 0.4 20 4 21 305 16 0 16 0 2.6 0 3.2 2.5 10/03/2004 22:50:00 10.2 0.8 11.8 7.6 10.4 0.9 12.2 7.6 0.4 0 0.4 0.4 17 5 25 305 15 0 15 0 2.7 0.1 3.4 2.5 10/03/2004 23:00:00 10 0.7 11.8 8.4 10.2 0.8 12.2 8.8 0.4 0 0.4 0.4 17 6 23 305 14 0 14 0 2.7 0.1 3.2 2.5 10/03/2004 23:10:00 8.8 0.5 10.3 7.2 9.1 0.6 10.3 6.8 0.4 0 0.4 0.4 17 6 19 305 12 0 13 0 2.7 0.1 3.2 2.5 10/03/2004 23:20:00 9.6 0.8 11.5 7.2 9.9 0.9 11.8 7.2 0.4 0 0.4 0.4 8 5 7 305 12 0 12 0 2.8 0.1 3.4 2.7 10/03/2004 23:30:00 10.2 0.7 12.2 8 10.5 0.7 12.2 8.8 0.4 0 0.4 0.4 10 4 5 305 10 0 10 0 2.7 0 3.2 2.7 10/03/2004 23:40:00 10.2 0.9 12.2 8 10.4 1 12.6 8 0.4 0 0.4 0.4 13 5 8 305 9 0 9 0 2.7 0 3.2 2.7 10/03/2004 23:50:00 10.5 0.6 12.2 8.4 10.8 0.7 12.6 8.8 0.4 0 0.4 0.4 13 4 14 305 9 0 9 0 2.6 0 3.2 2.5 10/04/2004 00:00:00 10 1 12.6 6.8 10.2 1 12.6 7.6 0.4 0 0.4 0.4 16 4 17 305 9 0 9 0 2.6 0 3.2 2.5 10/04/2004 00:10:00 10.2 0.8 11.8 8 10.4 0.9 12.2 8 0.4 0 0.4 0.4 13 6 15 305 10 0 10 0 2.5 0.1 3.2 2.2 10/04/2004 00:20:00 10.2 0.5 11.8 8.8 10.4 0.6 11.8 8.8 0.4 0 0.4 0.4 29 5 29 305 10 0 10 0 2.5 0.1 2.9 2.2 10/04/2004 00:30:00 9 0.6 10.3 7.2 9.1 0.6 10.3 7.6 0.4 0 0.4 0.4 32 4 37 305 11 0 11 0 2.2 0 2.7 2 10/04/2004 00:40:00 8.9 0.7 11.1 6.5 9.1 0.7 11.5 6.8 0.4 0 0.4 0.4 32 4 37 305 12 0 12 0 2.2 0.1 2.7 2.2 10/04/2004 00:50:00 9 0.7 11.1 7.2 9 0.7 11.1 7.2 0.4 0 0.4 0.4 26 5 19 305 13 0 13 0 2.3 0.1 2.9 2.2 10/04/2004 01:00:00 9.8 0.9 11.8 7.2 10 1 12.2 7.2 0.4 0 0.4 0.4 20 6 12 305 12 0 13 0 2.5 0 2.9 2.2 10/04/2004 01:10:00 9.2 0.6 10.7 7.6 9.4 0.6 11.1 8 0.4 0 0.4 0.4 23 7 31 305 12 0 12 0 2.5 0 3.2 2.2 10/04/2004 01:20:00 9.8 0.8 11.5 7.6 10 0.8 11.5 8 0.4 0 0.4 0.4 22 4 22 305 12 0 12 0 2.6 0 3.2 2.5 10/04/2004 01:30:00 9 0.7 10.7 7.2 9.1 0.7 11.1 7.2 0.4 0 0.4 0.4 21 4 25 305 11 0 11 0 2.7 0.1 3.2 2.5 10/04/2004 01:40:00 9.6 0.8 12.2 7.6 9.8 0.9 12.6 7.6 0.4 0 0.4 0.4 14 5 9 305 11 0 11 0 2.8 0.1 3.4 2.7 10/04/2004 01:50:00 9.9 0.7 11.8 8 10 0.8 11.8 7.6 0.4 0 0.4 0.4 16 4 14 305 10 0 11 0 2.9 0.1 3.4 2.7 10/04/2004 02:00:00 10.1 0.9 12.2 8 10.4 0.9 12.6 8.4 0.4 0 0.4 0.4 10 4 6 305 10 0 9 0 2.9 0 3.4 2.7 10/04/2004 02:10:00 9.7 0.9 11.5 7.2 9.9 0.9 11.8 7.6 0.4 0 0.4 0.4 9 4 10 305 9 0 9 0 2.9 0.1 3.4 2.7 10/04/2004 02:20:00 9.9 0.6 11.5 8 10.3 0.7 11.8 8.4 0.4 0 0.4 0.4 2 6 8 305 8 0 8 0 2.8 0.1 3.2 2.7 10/04/2004 02:30:00 9.2 0.7 11.1 6.5 9.5 0.9 11.5 6.8 0.4 0 0.4 0.4 2 5 4 305 8 0 8 0 2.8 0.1 3.4 2.7 10/04/2004 02:40:00 9.9 0.7 12.2 8.4 10.3 0.8 13 8.4 0.4 0 0.4 0.4 2 4 359 305 8 0 8 0 3 0 3.4 2.9 10/04/2004 02:50:00 10.1 0.8 13.3 8 10.3 0.9 14.1 8.4 0.4 0 0.4 0.4 10 6 8 305 7 0 7 0 2.9 0 3.4 2.7 10/04/2004 03:00:00 10.3 0.6 11.5 9.1 10.6 0.6 12.2 9.1 0.4 0 0.4 0.4 15 4 13 305 7 0 7 0 2.8 0 3.2 2.7 10/04/2004 03:10:00 9.8 0.9 11.8 7.2 10 1 12.6 7.6 0.4 0 0.4 0.4 11 5 16 305 7 0 7 0 2.8 0.1 3.2 2.7 10/04/2004 03:20:00 10 0.7 11.8 7.6 10.2 0.7 12.2 8 0.4 0 0.4 0.4 11 5 8 305 6 0 6 0 2.8 0.1 3.4 2.7 10/04/2004 03:30:00 9.8 0.8 12.2 7.6 10 0.8 12.6 8 0.4 0 0.4 0.4 10 4 12 305 6 0 6 0 2.8 0.2 3.4 2.7 10/04/2004 03:40:00 10.2 0.8 12.2 7.6 10.4 0.9 13 7.6 0.4 0 0.4 0.4 9 5 2 305 5 0 6 0 2.8 0.1 3.4 2.7 10/04/2004 03:50:00 10.3 0.8 11.8 6.8 10.6 0.9 12.6 8 0.4 0 0.4 0.4 11 5 2 305 5 0 5 0 3 0.1 3.4 2.9 10/04/2004 04:00:00 10.2 0.9 12.2 8 10.3 1 12.2 8 0.4 0 0.4 0.4 17 5 19 305 5 0 5 0 2.6 0.2 3.2 2.2 10/04/2004 04:10:00 10.2 0.6 11.5 8.4 10.3 0.7 11.8 8.4 0.4 0 0.4 0.4 11 4 11 305 6 0 7 0 2.3 0.1 2.7 2.2 10/04/2004 04:20:00 9.2 0.8 11.1 7.2 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 3 4 2 305 8 1 7 0 2.3 0.1 2.9 2.2 10/04/2004 04:30:00 8.8 0.8 10.7 7.2 9 0.8 11.1 7.2 0.4 0 0.4 0.4 7 7 9 305 10 0 10 0 2.6 0.1 3.2 2.5 10/04/2004 04:40:00 9 1 10.7 6.1 9.1 1 11.1 6.1 0.4 0 0.4 0.4 25 7 23 305 11 0 10 0 2.8 0.2 3.7 2.5 10/04/2004 04:50:00 10.2 0.6 11.5 8 10.3 0.7 11.8 8 0.4 0 0.4 0.4 22 5 25 305 12 0 12 0 3.1 0 3.7 2.9 10/04/2004 05:00:00 9.8 0.9 11.8 7.2 10 1 11.8 7.2 0.4 0 0.4 0.4 20 5 14 305 12 0 12 0 3.2 0 3.7 2.9 10/04/2004 05:10:00 9.6 0.6 11.1 8.4 9.8 0.7 11.5 8 0.4 0 0.4 0.4 26 4 27 305 13 0 13 0 3.3 0.1 3.9 3.2 10/04/2004 05:20:00 9.6 0.6 11.1 8 9.7 0.6 11.5 8 0.4 0 0.4 0.4 29 5 23 305 12 0 12 0 3.3 0.1 3.7 3.2 10/04/2004 05:30:00 9.6 0.6 11.5 8 9.8 0.7 11.8 8 0.4 0 0.4 0.4 25 5 29 305 12 0 13 0 3.3 0 3.7 3.2 10/04/2004 05:40:00 9.6 0.7 11.5 8 9.7 0.7 11.5 8 0.4 0 0.4 0.4 37 6 39 305 12 0 13 0 3 0.2 3.7 2.7 10/04/2004 05:50:00 9.4 0.6 11.1 8 9.4 0.7 11.5 7.6 0.4 0 0.4 0.4 34 6 31 305 12 0 12 0 3.1 0.1 3.7 2.7 10/04/2004 06:00:00 9.7 0.5 11.1 8.4 9.9 0.6 11.1 7.6 0.4 0 0.4 0.4 25 3 29 305 13 0 13 0 3.3 0.1 3.7 3.2 10/04/2004 06:10:00 9.3 0.7 11.1 7.2 9.5 0.7 11.5 6.8 0.4 0 0.4 0.4 23 4 20 305 13 0 13 0 3.3 0 3.7 3.2 10/04/2004 06:20:00 9.5 0.6 10.7 7.6 9.6 0.6 11.1 7.6 0.4 0 0.4 0.4 23 5 23 305 12 0 13 0 3.3 0.1 3.7 3.2 10/04/2004 06:30:00 9.7 0.6 11.1 8 9.8 0.6 11.5 8 0.4 0 0.4 0.4 21 5 20 305 12 0 12 0 3.3 0.1 3.7 3.2 10/04/2004 06:40:00 9.7 0.6 11.5 8 9.9 0.7 11.8 8 0.4 0 0.4 0.4 24 5 19 305 10 0 11 0 3.3 0.1 3.7 3.2 10/04/2004 06:50:00 9.3 0.6 10.7 7.6 9.5 0.6 11.1 7.6 0.4 0 0.4 0.4 23 4 19 305 9 0 9 0 3.3 0.1 3.7 3.2 10/04/2004 07:00:00 9 0.5 10.3 7.2 9.2 0.6 10.7 7.2 0.4 0 0.4 0.4 26 3 22 305 8 0 9 0 3.2 0 3.7 3.2 10/04/2004 07:10:00 8.8 0.4 9.5 7.6 8.9 0.5 9.9 7.2 0.4 0 0.4 0.4 25 5 30 305 8 0 8 0 3.2 0 3.7 2.9 10/04/2004 07:20:00 8 0.6 9.5 5.7 8.2 0.7 9.9 6.1 0.4 0 0.4 0.4 18 5 11 305 8 0 7 0 3.1 0 3.7 2.9 10/04/2004 07:30:00 7.7 0.5 9.1 6.5 8 0.5 9.1 6.8 0.4 0 0.4 0.4 20 6 19 305 7 0 7 0 3.1 0.1 3.7 2.9 10/04/2004 07:40:00 7 0.4 8.4 5.7 7.1 0.4 8.4 6.1 0.4 0 0.4 0.4 24 5 18 305 6 0 6 0 3.1 0 3.7 2.9 10/04/2004 07:50:00 7.2 0.4 8.8 6.1 7.4 0.5 8.8 6.5 0.4 0 0.4 0.4 22 3 21 305 6 0 6 0 3.1 0 3.7 2.9 10/04/2004 08:00:00 6.3 0.5 7.6 5.3 6.5 0.5 8 5.3 0.4 0 0.4 0.4 21 4 17 305 5 0 5 0 3 0 3.4 2.9 10/04/2004 08:10:00 7.2 0.5 8.4 5.7 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 14 5 12 305 5 0 5 0 3.2 0 3.4 2.9 10/04/2004 08:20:00 7 0.5 8 5.7 7.3 0.5 8.4 6.1 0.4 0 0.4 0.4 19 5 26 305 4 0 5 0 3.3 0 3.7 3.2 10/04/2004 08:30:00 7.1 0.5 8.4 5.7 7.3 0.5 8.4 6.1 0.4 0 0.4 0.4 16 5 17 305 4 0 5 0 3.3 0 3.7 3.2 10/04/2004 08:40:00 7 0.5 8.8 6.1 7.2 0.6 8.8 6.1 0.4 0 0.4 0.4 16 4 16 305 4 0 5 0 3.1 0 3.4 2.9 10/04/2004 08:50:00 6.8 0.6 8.4 5.3 7.1 0.6 9.1 5.3 0.4 0 0.4 0.4 16 5 10 305 4 0 4 0 3.1 0 3.7 2.9 10/04/2004 09:00:00 6.8 0.4 8 5.7 7 0.4 8 5.7 0.4 0 0.4 0.4 19 6 12 305 4 0 4 0 3.3 0.1 3.7 2.9 10/04/2004 09:10:00 6.6 0.5 8 5.3 6.8 0.5 8 5.7 0.4 0 0.4 0.4 21 4 8 305 3 0 3 0 3.3 0.1 3.7 3.2 10/04/2004 09:20:00 6.6 0.5 8 5.3 6.8 0.5 8 5.3 0.4 0 0.4 0.4 21 5 28 305 3 0 3 0 3.3 0.1 3.7 3.2 10/04/2004 09:30:00 6.6 0.4 8 5.3 6.9 0.4 8 5.7 0.4 0 0.4 0.4 22 4 31 305 4 0 4 0 3.3 0.1 3.7 3.2 10/04/2004 09:40:00 6.9 0.4 8 5.7 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 23 6 21 305 4 0 4 0 3.4 0.1 3.9 3.2 10/04/2004 09:50:00 7.1 0.4 8.4 5.7 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 25 5 27 305 4 0 4 0 3.4 0.2 3.9 3.2 10/04/2004 10:00:00 7.1 0.6 8.4 5.7 7.3 0.6 8.4 5.7 0.4 0 0.4 0.4 28 5 22 305 4 0 4 0 3.5 0.2 4.2 3.2 10/04/2004 10:10:00 6.9 0.5 8.8 6.1 7.1 0.5 9.1 6.1 0.4 0 0.4 0.4 25 6 24 305 5 0 5 0 3.6 0.2 4.2 3.2 10/04/2004 10:20:00 7.2 0.4 8.8 6.1 7.4 0.5 9.1 6.1 0.4 0 0.4 0.4 25 5 29 305 5 0 5 0 3.6 0.2 4.2 3.4 10/04/2004 10:30:00 7.1 0.6 8.4 5.7 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 27 5 30 305 5 0 5 0 3.6 0.1 4.2 3.4 10/04/2004 10:40:00 7.3 0.4 8.4 6.1 7.5 0.4 8.4 6.1 0.4 0 0.4 0.4 26 5 25 305 5 0 5 0 3.7 0.1 4.2 3.4 10/04/2004 10:50:00 6.9 0.4 8 5.7 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 23 3 25 305 5 0 5 0 3.7 0.1 4.2 3.4 10/04/2004 11:00:00 6.9 0.5 8.4 5.3 7.1 0.6 8.4 5.3 0.4 0 0.4 0.4 21 6 22 305 5 0 5 0 3.8 0.1 4.2 3.7 10/04/2004 11:10:00 6.9 0.5 8 5.3 7.1 0.6 8.4 5.3 0.4 0 0.4 0.4 20 5 30 305 5 0 5 0 3.7 0.1 4.4 3.4 10/04/2004 11:20:00 7 0.4 8 5.7 7.2 0.5 8.4 6.1 0.4 0 0.4 0.4 22 4 22 305 7 0 6 0 3.3 0.1 3.7 3.2 10/04/2004 11:30:00 6.5 0.5 7.6 5.3 6.7 0.5 8 4.9 0.4 0 0.4 0.4 21 5 18 305 7 0 7 0 3.4 0.2 4.2 3.2 10/04/2004 11:40:00 6.9 0.5 8.4 4.9 7.1 0.6 8.4 4.6 0.4 0 0.4 0.4 20 6 16 305 7 0 7 0 3.6 0 4.2 3.4 10/04/2004 11:50:00 7.1 0.6 8.8 5.7 7.3 0.6 9.1 5.3 0.4 0 0.4 0.4 25 6 29 305 6 0 7 0 3.7 0.1 4.2 3.4 10/04/2004 12:00:00 7 0.7 8.8 4.9 7.2 0.7 8.8 4.9 0.4 0 0.4 0.4 26 5 30 305 6 0 6 0 3.4 0.1 3.9 3.2 10/04/2004 12:10:00 7.1 0.6 8.4 5.3 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 24 5 25 305 6 0 6 0 3.6 0 4.2 3.4 10/04/2004 12:20:00 7.2 0.5 8.8 5.7 7.4 0.5 8.8 6.1 0.4 0 0.4 0.4 25 4 23 305 6 0 6 0 3.6 0 4.2 3.4 10/04/2004 12:30:00 7 0.6 8.4 5.7 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 28 4 37 305 6 0 6 0 3.7 0 4.2 3.4 10/04/2004 12:40:00 6.9 0.6 8.4 5.3 7.1 0.6 8.8 5.7 0.4 0 0.4 0.4 25 4 29 305 6 0 6 0 3.7 0 4.4 3.7 10/04/2004 12:50:00 6.5 0.5 8.4 4.9 6.7 0.5 8 4.9 0.4 0 0.4 0.4 23 6 17 305 5 0 5 0 3.8 0.1 4.4 3.7 10/04/2004 13:00:00 6.2 0.5 7.2 5.3 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 18 6 12 305 6 0 6 0 3.9 0.1 4.4 3.7 10/04/2004 13:10:00 6.3 0.5 7.6 4.9 6.6 0.5 7.6 4.9 0.4 0 0.4 0.4 12 4 5 305 7 0 7 0 4 0 4.7 3.9 10/04/2004 13:20:00 6.1 0.5 7.2 4.9 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 13 4 14 305 6 0 6 0 4.1 0 4.7 4.2 10/04/2004 13:30:00 6.1 0.6 7.2 4.6 6.4 0.6 7.6 4.9 0.4 0 0.4 0.4 11 4 14 305 6 0 6 0 4.2 0 4.7 3.9 10/04/2004 13:40:00 6.4 0.4 7.2 4.9 6.7 0.4 8 5.3 0.4 0 0.4 0.4 12 3 12 305 6 0 6 0 4.3 0 4.7 4.2 10/04/2004 13:50:00 6.4 0.5 7.6 4.9 6.6 0.5 7.6 4.9 0.4 0 0.4 0.4 17 4 21 305 6 0 6 0 4.3 0 4.7 4.2 10/04/2004 14:00:00 6.3 0.5 7.2 4.6 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 19 4 19 305 7 0 7 0 4.4 0.1 4.9 4.2 10/04/2004 14:10:00 6.2 0.5 7.2 4.6 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 21 3 21 305 7 0 7 0 4.4 0.1 4.9 4.2 10/04/2004 14:20:00 6.5 0.5 7.2 5.3 6.7 0.5 8 5.3 0.4 0 0.4 0.4 24 4 17 305 7 0 7 0 4.4 0 4.9 4.4 10/04/2004 14:30:00 6.4 0.4 7.6 4.9 6.6 0.5 7.6 4.9 0.4 0 0.4 0.4 19 4 20 305 8 0 7 0 4.4 0 4.7 4.2 10/04/2004 14:40:00 5.9 0.4 6.8 4.9 6.1 0.4 7.2 4.9 0.4 0 0.4 0.4 26 5 26 305 8 0 8 0 4.4 0 4.9 4.2 10/04/2004 14:50:00 5.8 0.3 6.5 4.9 6.1 0.4 6.8 4.6 0.4 0 0.4 0.4 22 5 21 305 9 0 9 0 4.4 0 4.9 4.2 10/04/2004 15:00:00 5.9 0.4 6.8 4.9 6.1 0.5 7.2 4.9 0.4 0 0.4 0.4 29 3 31 305 8 0 8 0 4.5 0.1 4.9 4.4 10/04/2004 15:10:00 5.9 0.4 7.2 4.9 6 0.5 7.2 4.9 0.4 0 0.4 0.4 31 3 32 305 7 0 8 0 4.6 0 5.2 4.4 10/04/2004 15:20:00 5.7 0.4 6.5 4.6 6 0.4 6.8 4.6 0.4 0 0.4 0.4 31 3 30 305 6 0 6 0 4.7 0 5.2 4.4 10/04/2004 15:30:00 6.5 0.6 7.6 4.9 6.7 0.6 8 4.9 0.4 0 0.4 0.4 28 5 26 305 5 0 5 0 4.7 0 5.2 4.4 10/04/2004 15:40:00 6.6 0.5 7.6 5.3 6.8 0.5 8.4 5.3 0.4 0 0.4 0.4 31 3 35 305 5 0 5 0 4.5 0.1 4.9 4.4 10/04/2004 15:50:00 6.6 0.5 7.2 4.9 6.8 0.5 7.6 5.3 0.4 0 0.4 0.4 29 4 30 305 5 0 5 0 4.7 0 5.2 4.4 10/04/2004 16:00:00 6.7 0.5 7.6 4.9 6.9 0.5 8 5.3 0.4 0 0.4 0.4 31 3 32 305 5 0 5 0 4.6 0 4.9 4.4 10/04/2004 16:10:00 7.4 0.4 8.4 6.1 7.6 0.5 8.8 6.5 0.4 0 0.4 0.4 31 2 30 305 5 0 5 0 4.6 0 4.9 4.4 10/04/2004 16:20:00 7.2 0.5 8 5.7 7.3 0.5 8.4 6.1 0.4 0 0.4 0.4 29 3 32 305 6 0 6 0 4.6 0 4.9 4.4 10/04/2004 16:30:00 7.7 0.4 8.4 6.5 7.9 0.4 8.8 6.8 0.4 0 0.4 0.4 31 3 29 305 7 0 7 0 4.5 0.1 4.9 4.4 10/04/2004 16:40:00 8 0.5 9.1 6.5 8.2 0.5 9.1 6.5 0.4 0 0.4 0.4 32 3 28 305 8 0 8 0 4.5 0.1 4.9 4.4 10/04/2004 16:50:00 8 0.5 9.1 6.5 8 0.6 9.5 6.5 0.4 0 0.4 0.4 32 3 35 305 8 0 8 0 4.5 0.1 4.9 4.4 10/04/2004 17:00:00 8.2 0.4 9.1 6.8 8.3 0.4 9.1 6.8 0.4 0 0.4 0.4 32 3 29 305 9 0 9 0 4.5 0.1 4.9 4.4 10/04/2004 17:10:00 8 0.5 9.5 6.5 8.2 0.6 9.5 6.5 0.4 0 0.4 0.4 35 3 32 305 9 0 9 0 4.6 0 4.9 4.4 10/04/2004 17:20:00 8 0.5 9.5 6.8 8.1 0.5 9.5 6.8 0.4 0 0.4 0.4 36 3 30 305 10 0 10 0 4.6 0.1 4.9 4.4 10/04/2004 17:30:00 8.6 0.5 9.5 7.2 8.8 0.5 9.9 7.2 0.4 0 0.4 0.4 35 3 31 305 10 0 10 0 4.7 0 4.9 4.4 10/04/2004 17:40:00 8.4 0.5 9.5 6.8 8.6 0.5 9.9 7.2 0.4 0 0.4 0.4 35 3 33 305 10 0 10 0 4.7 0 5.2 4.7 10/04/2004 17:50:00 8.4 0.5 9.5 6.8 8.6 0.6 9.9 6.5 0.4 0 0.4 0.4 37 4 35 305 10 0 10 0 4.6 0.2 5.2 4.4 10/04/2004 18:00:00 8.4 0.6 9.5 6.8 8.5 0.6 9.5 6.8 0.4 0 0.4 0.4 35 3 37 305 11 0 11 0 4.5 0.1 4.9 4.4 10/04/2004 18:10:00 9 0.4 9.9 7.6 9.1 0.5 9.9 8 0.4 0 0.4 0.4 38 3 39 305 12 0 12 0 4.6 0 4.9 4.4 10/04/2004 18:20:00 8.8 0.5 10.3 7.2 8.9 0.5 9.9 7.2 0.4 0 0.4 0.4 36 4 30 305 12 0 12 0 4.5 0.1 4.9 4.4 10/04/2004 18:30:00 8.9 0.4 9.5 8 9 0.4 9.9 7.6 0.4 0 0.4 0.4 37 3 39 305 12 0 12 0 4.5 0.1 4.9 4.4 10/04/2004 18:40:00 8.7 0.5 9.9 7.2 8.8 0.4 9.9 7.2 0.4 0 0.4 0.4 33 3 35 305 12 0 12 0 4.4 0.1 4.9 4.4 10/04/2004 18:50:00 8.6 0.5 9.5 7.2 8.7 0.6 9.9 6.8 0.4 0 0.4 0.4 34 4 36 305 12 0 12 0 4.4 0.1 4.9 4.4 10/04/2004 19:00:00 8.6 0.5 9.5 6.5 8.7 0.5 9.9 6.5 0.4 0 0.4 0.4 31 3 29 305 12 0 12 0 4.4 0.1 4.9 4.4 10/04/2004 19:10:00 8.5 0.6 9.5 6.8 8.6 0.6 9.9 6.5 0.4 0 0.4 0.4 32 4 29 305 12 0 12 0 4.4 0 4.9 4.2 10/04/2004 19:20:00 8.6 0.5 9.5 6.8 8.8 0.5 9.9 7.6 0.4 0 0.4 0.4 32 3 32 305 13 0 13 0 4.4 0 4.7 4.2 10/04/2004 19:30:00 8.7 0.4 9.9 7.6 8.8 0.5 9.9 7.2 0.4 0 0.4 0.4 30 3 30 305 13 0 13 0 4.4 0 4.7 4.2 10/04/2004 19:40:00 8.6 0.5 9.9 6.8 8.7 0.5 9.9 7.2 0.4 0 0.4 0.4 31 5 32 305 13 0 13 0 4.3 0 4.7 4.2 10/04/2004 19:50:00 8.6 0.4 9.5 7.6 8.8 0.5 9.9 7.2 0.4 0 0.4 0.4 28 3 20 305 14 0 13 0 4.2 0 4.7 4.2 10/04/2004 20:00:00 8.3 0.4 9.5 6.8 8.5 0.5 9.5 6.5 0.4 0 0.4 0.4 28 4 31 305 14 0 14 0 4.2 0.1 4.7 4.2 10/04/2004 20:10:00 8.3 0.5 9.1 6.5 8.4 0.5 9.5 6.5 0.4 0 0.4 0.4 32 4 25 305 14 0 14 0 4.2 0.1 4.7 4.2 10/04/2004 20:20:00 8.1 0.4 9.1 6.8 8.3 0.4 9.5 6.8 0.4 0 0.4 0.4 30 5 36 305 15 0 15 0 4.1 0 4.7 4.2 10/04/2004 20:30:00 8 0.4 9.1 6.8 8.2 0.5 9.1 6.8 0.4 0 0.4 0.4 29 3 30 305 15 0 15 0 4.1 0 4.7 3.9 10/04/2004 20:40:00 7.8 0.5 8.8 6.1 7.9 0.5 9.1 6.5 0.4 0 0.4 0.4 33 4 28 305 16 0 16 0 4.1 0 4.7 4.2 10/04/2004 20:50:00 8 0.3 8.8 6.8 8.2 0.4 9.1 6.5 0.4 0 0.4 0.4 31 2 33 305 16 0 16 0 4.1 0 4.7 3.9 10/04/2004 21:00:00 7.5 0.4 8.4 6.5 7.8 0.4 8.8 6.5 0.4 0 0.4 0.4 30 4 27 305 16 0 16 0 4.1 0 4.7 3.9 10/04/2004 21:10:00 7.6 0.4 8.4 6.5 7.8 0.5 8.8 6.1 0.4 0 0.4 0.4 31 4 32 305 17 0 16 0 4 0 4.4 3.9 10/04/2004 21:20:00 7.6 0.4 8.8 6.5 7.8 0.5 9.1 6.1 0.4 0 0.4 0.4 25 4 23 305 17 0 17 0 4 0.1 4.7 3.9 10/04/2004 21:30:00 7.6 0.5 8.8 6.1 7.8 0.5 8.8 6.5 0.4 0 0.4 0.4 29 4 32 305 17 0 17 0 4 0.1 4.7 3.9 10/04/2004 21:40:00 7.5 0.5 8.8 5.7 7.6 0.5 8.8 6.1 0.4 0 0.4 0.4 28 4 27 305 17 0 17 0 4 0 4.4 3.9 10/04/2004 21:50:00 7.3 0.6 8.4 5.7 7.4 0.6 9.1 6.1 0.4 0 0.4 0.4 27 3 32 305 17 0 17 0 4 0.2 4.7 3.9 10/04/2004 22:00:00 7.1 0.5 8.4 6.1 7.2 0.5 8.4 5.3 0.4 0 0.4 0.4 24 5 21 305 18 0 18 0 4 0 4.4 3.9 10/04/2004 22:10:00 7 0.5 8.4 5.7 7.2 0.6 8.4 5.7 0.4 0 0.4 0.4 24 4 22 305 18 0 18 0 4 0.1 4.4 3.9 10/04/2004 22:20:00 6.7 0.6 8 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 26 4 28 305 18 0 18 0 3.9 0.1 4.4 3.7 10/04/2004 22:30:00 6.7 0.5 8 5.3 6.9 0.5 8.4 5.3 0.4 0 0.4 0.4 27 6 31 305 18 0 18 0 3.9 0.1 4.4 3.7 10/04/2004 22:40:00 7 0.4 8 5.7 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 26 5 39 305 18 0 18 0 3.9 0.1 4.4 3.7 10/04/2004 22:50:00 6.5 0.4 7.6 5.7 6.7 0.4 7.6 5.3 0.4 0 0.4 0.4 28 7 30 305 19 0 19 0 3.9 0.1 4.4 3.7 10/04/2004 23:00:00 6.7 0.4 7.6 5.7 6.9 0.4 8 5.3 0.4 0 0.4 0.4 26 3 24 305 19 0 19 0 4 0.1 4.4 3.9 10/04/2004 23:10:00 6.8 0.4 8 5.3 6.9 0.5 8.4 5.7 0.4 0 0.4 0.4 24 4 21 305 19 0 19 0 4 0 4.7 3.9 10/04/2004 23:20:00 6.8 0.5 8 5.3 7 0.6 8.4 5.7 0.4 0 0.4 0.4 22 5 16 305 19 0 19 0 4.1 0.1 4.7 4.2 10/04/2004 23:30:00 6.7 0.6 8.4 5.3 6.8 0.6 8.4 4.9 0.4 0 0.4 0.4 21 4 25 305 19 0 20 0 4.2 0.1 4.7 4.2 10/04/2004 23:40:00 6.6 0.4 7.6 5.3 6.8 0.4 7.6 5.7 0.4 0 0.4 0.4 22 5 24 305 19 0 19 0 4.2 0 4.7 4.2 10/04/2004 23:50:00 6.5 0.5 7.6 5.3 6.8 0.5 8.4 5.3 0.4 0 0.4 0.4 25 4 29 305 19 0 19 0 4.2 0 4.7 4.2 10/05/2004 00:00:00 6.6 0.5 8 5.3 6.8 0.5 8 5.7 0.4 0 0.4 0.4 22 4 23 305 19 0 19 0 4.2 0.1 4.7 4.2 10/05/2004 00:10:00 6.4 0.5 8 4.9 6.6 0.6 8 4.9 0.4 0 0.4 0.4 20 6 22 305 19 0 19 0 4.2 0 4.7 4.2 10/05/2004 00:20:00 6.6 0.5 8 5.3 6.9 0.5 8 5.7 0.4 0 0.4 0.4 18 6 7 305 19 0 19 0 4.2 0.1 4.7 4.2 10/05/2004 00:30:00 6.7 0.6 8 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 16 5 20 305 18 0 18 0 4.1 0 4.7 3.9 10/05/2004 00:40:00 7 0.5 8.4 5.7 7.2 0.5 8.8 5.7 0.4 0 0.4 0.4 18 6 24 305 18 0 18 0 4 0.2 4.4 3.9 10/05/2004 00:50:00 6.7 0.6 8.4 5.3 6.9 0.6 8.4 5.7 0.4 0 0.4 0.4 17 5 14 305 18 0 18 0 4.1 0.1 4.7 3.9 10/05/2004 01:00:00 6.7 0.5 8 4.9 7 0.5 8 5.7 0.4 0 0.4 0.4 17 4 18 305 18 0 18 0 4.1 0.1 4.7 3.9 10/05/2004 01:10:00 6.6 0.5 7.6 5.3 6.8 0.5 8 5.7 0.4 0 0.4 0.4 13 4 11 305 18 0 18 0 4.1 0.1 4.7 4.2 10/05/2004 01:20:00 7 0.5 8.4 5.7 7.4 0.5 8.8 6.1 0.4 0 0.4 0.4 11 3 11 305 18 0 18 0 4 0.2 4.4 3.9 10/05/2004 01:30:00 6.9 0.6 8 5.3 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 18 3 14 305 18 0 18 0 4 0.2 4.4 3.7 10/05/2004 01:40:00 6.6 0.4 8 5.7 6.8 0.5 8 5.3 0.4 0 0.4 0.4 21 3 24 305 18 0 18 0 3.9 0.2 4.4 3.7 10/05/2004 01:50:00 6.3 0.5 7.2 4.9 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 22 4 26 305 18 0 18 0 3.9 0.1 4.4 3.7 10/05/2004 02:00:00 6.2 0.5 7.2 4.9 6.4 0.4 7.6 5.3 0.4 0 0.4 0.4 27 4 23 305 18 0 18 0 3.9 0.1 4.4 3.7 10/05/2004 02:10:00 6 0.6 7.6 4.6 6.3 0.6 8 4.9 0.4 0 0.4 0.4 24 6 25 305 18 0 18 0 4 0.2 4.4 3.7 10/05/2004 02:20:00 6.2 0.5 7.2 4.9 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 32 4 33 305 18 0 18 0 3.9 0.2 4.4 3.7 10/05/2004 02:30:00 6.4 0.4 7.2 5.3 6.7 0.5 7.6 5.7 0.4 0 0.4 0.4 32 4 40 305 18 0 18 0 3.9 0.1 4.4 3.7 10/05/2004 02:40:00 6 0.4 6.8 4.9 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 28 4 35 305 18 0 18 0 3.8 0.1 4.4 3.7 10/05/2004 02:50:00 5.4 0.4 6.5 4.2 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 29 5 24 305 18 0 18 0 3.7 0 4.4 3.4 10/05/2004 03:00:00 5.5 0.5 6.5 4.2 5.7 0.5 6.8 4.2 0.4 0 0.4 0.4 32 5 36 305 18 0 18 0 3.7 0 4.2 3.4 10/05/2004 03:10:00 5.2 0.4 6.5 3.8 5.4 0.4 6.5 4.6 0.4 0 0.4 0.4 28 5 30 305 18 0 18 0 3.7 0 4.2 3.4 10/05/2004 03:20:00 5 0.4 6.1 4.2 5.3 0.4 6.5 3.8 0.4 0 0.4 0.4 27 6 15 305 18 0 18 0 3.6 0 4.2 3.4 10/05/2004 03:30:00 4.9 0.4 6.1 4.2 5.2 0.4 6.1 4.2 0.4 0 0.4 0.4 29 3 32 305 18 0 18 0 3.6 0 4.2 3.4 10/05/2004 03:40:00 5 0.4 5.7 3.8 5.3 0.4 6.5 4.2 0.4 0 0.4 0.4 28 3 30 305 19 0 19 0 3.6 0 4.2 3.4 10/05/2004 03:50:00 4.9 0.6 6.1 3 5.2 0.6 6.1 3.8 0.4 0 0.4 0.4 23 5 25 305 19 0 19 0 3.6 0 4.2 3.4 10/05/2004 04:00:00 5 0.4 6.1 4.2 5.3 0.4 6.5 4.6 0.4 0 0.4 0.4 26 4 27 305 19 0 19 0 3.7 0 4.2 3.7 10/05/2004 04:10:00 5.4 0.4 6.1 4.2 5.6 0.4 6.5 4.6 0.4 0 0.4 0.4 27 5 25 305 19 0 19 0 3.8 0.1 4.4 3.7 10/05/2004 04:20:00 5.2 0.3 6.1 4.6 5.6 0.3 6.5 4.9 0.4 0 0.4 0.4 28 3 31 305 19 0 19 0 3.9 0.1 4.4 3.7 10/05/2004 04:30:00 5.5 0.4 6.8 4.6 5.8 0.3 6.8 4.9 0.4 0 0.4 0.4 33 3 34 305 19 0 19 0 4 0.1 4.4 3.7 10/05/2004 04:40:00 5.7 0.4 6.5 4.9 6 0.4 6.8 4.9 0.4 0 0.4 0.4 35 3 34 305 19 0 19 0 4 0.1 4.4 3.9 10/05/2004 04:50:00 5.5 0.4 6.8 4.6 5.8 0.5 7.2 4.9 0.4 0 0.4 0.4 32 3 29 305 19 0 19 0 4 0.1 4.7 3.9 10/05/2004 05:00:00 5.6 0.5 6.5 4.2 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 34 4 31 305 19 0 19 0 4.2 0 4.7 4.2 10/05/2004 05:10:00 5.9 0.4 6.8 4.6 6.1 0.5 6.8 4.9 0.4 0 0.4 0.4 35 3 40 305 19 0 19 0 4.2 0 4.7 4.2 10/05/2004 05:20:00 6 0.3 6.8 4.9 6.2 0.4 6.8 5.3 0.4 0 0.4 0.4 34 2 33 305 19 0 19 0 4.3 0 4.7 4.2 10/05/2004 05:30:00 6.2 0.5 6.8 4.9 6.4 0.5 7.2 5.3 0.4 0 0.4 0.4 32 3 29 305 19 0 19 0 4.4 0.1 4.9 4.2 10/05/2004 05:40:00 6.3 0.4 7.2 4.9 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 30 3 28 305 19 0 19 0 4.4 0.1 4.9 4.4 10/05/2004 05:50:00 6.5 0.5 7.2 4.9 6.7 0.5 7.6 5.3 0.4 0 0.4 0.4 30 4 29 305 19 0 19 0 4.4 0.1 4.9 4.4 10/05/2004 06:00:00 7.1 0.4 8 6.1 7.3 0.4 8 6.1 0.4 0 0.4 0.4 34 2 35 305 19 0 19 0 4.4 0.1 4.9 4.4 10/05/2004 06:10:00 7.3 0.4 8 6.1 7.5 0.4 8.4 6.1 0.4 0 0.4 0.4 34 3 36 305 19 0 19 0 4.4 0.1 4.9 4.4 10/05/2004 06:20:00 7 0.4 8 5.7 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 32 2 33 305 19 0 19 0 4.4 0.1 4.9 4.4 10/05/2004 06:30:00 6.6 0.5 7.6 4.9 6.9 0.4 7.6 5.3 0.4 0 0.4 0.4 31 3 30 305 19 0 19 0 4.4 0.1 4.9 4.4 10/05/2004 06:40:00 6.4 0.3 7.2 5.7 6.7 0.4 7.6 5.7 0.4 0 0.4 0.4 28 3 26 305 20 0 19 0 4.4 0.1 4.9 4.4 10/05/2004 06:50:00 6.3 0.4 7.2 4.9 6.6 0.4 7.6 4.9 0.4 0 0.4 0.4 26 3 27 305 20 0 20 0 4.4 0.2 4.9 4.4 10/05/2004 07:00:00 6.2 0.4 7.2 4.9 6.5 0.4 7.6 5.3 0.4 0 0.4 0.4 22 4 27 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 07:10:00 6.3 0.5 7.6 4.9 6.6 0.5 8 4.9 0.4 0 0.4 0.4 14 5 12 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 07:20:00 6.8 0.4 8 5.3 7.2 0.5 8 5.3 0.4 0 0.4 0.4 17 3 19 305 20 0 20 0 4.6 0.1 5.2 4.4 10/05/2004 07:30:00 6.9 0.6 8 5.3 7.3 0.6 8.4 5.3 0.4 0 0.4 0.4 13 3 12 305 20 0 20 0 4.7 0.1 5.2 4.4 10/05/2004 07:40:00 7.5 0.4 8.8 6.1 7.8 0.4 9.1 6.5 0.4 0 0.4 0.4 12 3 12 305 20 0 20 0 4.7 0 5.2 4.7 10/05/2004 07:50:00 7.9 0.4 8.8 6.5 8.1 0.5 9.1 6.8 0.4 0 0.4 0.4 11 3 7 305 20 0 20 0 4.7 0 4.9 4.7 10/05/2004 08:00:00 7.8 0.5 8.8 6.5 8.1 0.5 9.1 6.1 0.4 0 0.4 0.4 12 3 10 305 20 0 20 0 4.7 0.1 5.2 4.7 10/05/2004 08:10:00 8 0.4 8.8 6.5 8.3 0.4 9.1 6.8 0.4 0 0.4 0.4 12 3 7 305 20 0 20 0 4.7 0 5.2 4.4 10/05/2004 08:20:00 7.6 0.4 8.8 6.5 7.9 0.5 9.1 6.5 0.4 0 0.4 0.4 14 3 13 305 20 0 20 0 4.7 0 5.2 4.4 10/05/2004 08:30:00 7.9 0.5 9.1 6.8 8.2 0.6 9.5 6.8 0.4 0 0.4 0.4 17 3 15 305 20 0 20 0 4.7 0.1 5.2 4.4 10/05/2004 08:40:00 8 0.4 8.8 6.8 8.2 0.5 9.5 6.5 0.4 0 0.4 0.4 24 3 24 305 20 0 20 0 4.7 0.1 5.2 4.4 10/05/2004 08:50:00 8.3 0.5 9.1 7.2 8.6 0.5 9.5 7.2 0.4 0 0.4 0.4 25 3 24 305 20 0 20 0 4.6 0.1 4.9 4.4 10/05/2004 09:00:00 8.3 0.5 9.5 6.5 8.5 0.6 9.5 6.5 0.4 0 0.4 0.4 24 3 24 305 20 0 20 0 4.6 0 5.2 4.4 10/05/2004 09:10:00 8.7 0.5 9.5 7.2 8.9 0.5 9.9 6.8 0.4 0 0.4 0.4 27 3 26 305 20 0 20 0 4.5 0 4.9 4.4 10/05/2004 09:20:00 8.4 0.4 9.1 7.2 8.6 0.5 9.5 7.2 0.4 0 0.4 0.4 26 3 24 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 09:30:00 8.3 0.5 9.1 6.8 8.4 0.5 9.5 6.8 0.4 0 0.4 0.4 26 3 27 305 21 0 21 0 4.5 0.1 4.9 4.4 10/05/2004 09:40:00 8.3 0.5 9.1 6.8 8.5 0.6 9.9 7.2 0.4 0 0.4 0.4 28 3 26 305 21 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 09:50:00 8.2 0.5 9.1 6.5 8.4 0.5 9.5 6.1 0.4 0 0.4 0.4 32 3 32 305 21 0 21 0 4.5 0.1 4.9 4.4 10/05/2004 10:00:00 8.5 0.4 9.5 7.2 8.7 0.4 9.5 7.6 0.4 0 0.4 0.4 34 4 34 305 21 0 21 0 4.5 0.1 4.9 4.4 10/05/2004 10:10:00 8.6 0.4 9.5 7.2 8.9 0.5 9.9 7.2 0.4 0 0.4 0.4 36 3 33 305 21 0 21 0 4.5 0.1 4.9 4.4 10/05/2004 10:20:00 8.4 0.6 9.9 6.5 8.6 0.6 10.3 6.8 0.4 0 0.4 0.4 36 3 34 305 21 0 21 0 4.5 0.1 4.9 4.4 10/05/2004 10:30:00 8.4 0.4 9.5 7.2 8.6 0.5 9.9 7.2 0.4 0 0.4 0.4 36 3 35 305 21 0 21 0 4.6 0.1 4.9 4.4 10/05/2004 10:40:00 8.6 0.5 9.5 6.8 8.9 0.6 10.3 6.8 0.4 0 0.4 0.4 32 3 34 305 21 0 21 0 4.6 0.1 4.9 4.4 10/05/2004 10:50:00 8.8 0.6 10.3 7.2 9 0.6 10.3 6.5 0.4 0 0.4 0.4 33 3 29 305 21 0 21 0 4.6 0.1 4.9 4.4 10/05/2004 11:00:00 8.5 0.5 9.5 6.5 8.6 0.5 9.5 6.8 0.4 0 0.4 0.4 33 3 35 305 21 0 21 0 4.6 0 5.2 4.4 10/05/2004 11:10:00 8.8 0.6 9.9 6.8 9 0.6 10.3 7.2 0.4 0 0.4 0.4 34 3 33 305 21 0 21 0 4.7 0 4.9 4.4 10/05/2004 11:20:00 8.8 0.5 9.9 7.2 8.9 0.5 9.9 7.2 0.4 0 0.4 0.4 33 3 36 305 21 0 21 0 4.7 0 5.2 4.4 10/05/2004 11:30:00 8.8 0.5 9.9 7.6 9 0.5 10.3 7.6 0.4 0 0.4 0.4 31 5 32 305 21 0 21 0 4.7 0 5.2 4.4 10/05/2004 11:40:00 8.7 0.6 9.9 7.2 9 0.6 10.3 7.2 0.4 0 0.4 0.4 33 3 34 305 21 0 21 0 4.7 0 5.2 4.4 10/05/2004 11:50:00 9 0.7 10.3 6.8 9.1 0.7 10.7 6.8 0.4 0 0.4 0.4 31 3 30 305 21 0 21 0 4.6 0.1 4.9 4.4 10/05/2004 12:00:00 9.1 0.5 9.9 7.6 9.2 0.6 10.3 7.6 0.4 0 0.4 0.4 32 3 30 305 21 0 21 0 4.6 0 4.9 4.4 10/05/2004 12:10:00 9.1 0.6 10.3 7.6 9.2 0.7 10.7 7.2 0.4 0 0.4 0.4 34 3 38 305 21 0 21 0 4.6 0 4.9 4.4 10/05/2004 12:20:00 9.2 0.5 10.3 7.6 9.4 0.5 10.7 8 0.4 0 0.4 0.4 32 3 33 305 21 0 21 0 4.6 0 4.9 4.4 10/05/2004 12:30:00 9.2 0.6 10.7 7.6 9.3 0.6 10.7 7.6 0.4 0 0.4 0.4 32 3 32 305 21 0 21 0 4.6 0 4.9 4.4 10/05/2004 12:40:00 9.4 0.6 10.7 7.6 9.5 0.6 11.1 7.6 0.4 0 0.4 0.4 33 3 32 305 21 0 21 0 4.5 0 4.9 4.4 10/05/2004 12:50:00 9.4 0.6 10.7 8 9.5 0.7 10.7 7.6 0.4 0 0.4 0.4 31 3 32 305 21 0 21 0 4.5 0 4.9 4.4 10/05/2004 13:00:00 9.1 0.5 10.3 7.2 9.2 0.5 10.7 7.6 0.4 0 0.4 0.4 27 3 29 305 21 0 21 0 4.5 0.1 4.9 4.4 10/05/2004 13:10:00 9.4 0.6 10.7 7.2 9.5 0.6 10.7 7.6 0.4 0 0.4 0.4 30 3 28 305 21 0 21 0 4.5 0 4.9 4.4 10/05/2004 13:20:00 9.4 0.6 11.1 7.6 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 30 3 32 305 21 0 21 0 4.5 0 4.9 4.4 10/05/2004 13:30:00 9.6 0.6 11.1 7.6 9.7 0.7 11.1 7.2 0.4 0 0.4 0.4 32 3 36 305 21 0 21 0 4.5 0 4.9 4.4 10/05/2004 13:40:00 9.4 0.5 10.3 7.6 9.3 0.6 10.7 7.6 0.4 0 0.4 0.4 31 3 32 305 21 0 21 0 4.5 0 4.9 4.4 10/05/2004 13:50:00 8.9 0.6 10.3 7.2 8.8 0.7 10.3 6.8 0.4 0 0.4 0.4 31 3 35 305 21 0 21 0 4.5 0 4.7 4.4 10/05/2004 14:00:00 9 0.5 10.3 7.2 9.1 0.6 10.7 7.6 0.4 0 0.4 0.4 30 3 24 305 21 0 21 0 4.5 0.1 4.9 4.4 10/05/2004 14:10:00 8.6 0.6 10.3 6.8 8.7 0.7 10.7 6.5 0.4 0 0.4 0.4 30 3 34 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 14:20:00 8.9 0.5 10.3 7.2 8.8 0.5 9.9 7.2 0.4 0 0.4 0.4 29 3 27 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 14:30:00 8.7 0.6 9.9 6.5 8.6 0.7 9.9 6.5 0.4 0 0.4 0.4 29 3 30 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 14:40:00 8.9 0.4 9.9 7.2 9 0.5 10.3 7.2 0.4 0 0.4 0.4 28 2 27 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 14:50:00 8.3 0.5 9.1 6.8 8.4 0.5 9.5 6.8 0.4 0 0.4 0.4 27 3 27 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 15:00:00 8.1 0.5 9.5 6.5 8.2 0.6 9.5 6.5 0.4 0 0.4 0.4 29 3 35 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 15:10:00 8.4 0.6 9.5 6.5 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 28 2 28 305 20 0 20 0 4.4 0.1 4.9 4.4 10/05/2004 15:20:00 8 0.5 9.1 6.5 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 25 3 26 305 20 0 20 0 4.4 0 4.9 4.4 10/05/2004 15:30:00 7.9 0.6 9.1 6.1 7.9 0.6 9.1 6.5 0.4 0 0.4 0.4 26 3 25 305 20 0 20 0 4.4 0.1 4.9 4.2 10/05/2004 15:40:00 7.8 0.5 9.5 6.8 7.9 0.5 9.5 6.5 0.4 0 0.4 0.4 26 3 28 305 20 0 20 0 4.4 0.1 4.9 4.4 10/05/2004 15:50:00 7.9 0.6 9.1 6.1 8 0.6 9.9 6.1 0.4 0 0.4 0.4 28 3 24 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 16:00:00 8 0.5 9.5 6.5 8.1 0.6 9.1 6.1 0.4 0 0.4 0.4 30 3 29 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 16:10:00 8.1 0.6 9.1 6.1 8.2 0.6 9.5 6.5 0.4 0 0.4 0.4 30 3 29 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 16:20:00 8 0.4 9.1 6.8 8.1 0.5 9.1 6.1 0.4 0 0.4 0.4 30 3 33 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 16:30:00 7.8 0.6 9.5 6.5 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 31 3 29 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 16:40:00 8.3 0.6 9.9 6.8 8.3 0.6 9.9 6.1 0.4 0 0.4 0.4 31 3 29 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 16:50:00 8.7 0.5 9.9 7.2 8.7 0.5 9.9 7.2 0.4 0 0.4 0.4 33 3 35 305 20 0 20 0 4.5 0 4.7 4.4 10/05/2004 17:00:00 8.3 0.4 9.5 7.2 8.4 0.5 9.9 6.8 0.4 0 0.4 0.4 37 3 33 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 17:10:00 8.4 0.6 9.5 6.8 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 35 3 39 305 20 0 20 0 4.5 0.1 4.9 4.4 10/05/2004 17:20:00 8.4 0.6 9.9 6.5 8.5 0.5 9.9 6.8 0.4 0 0.4 0.4 35 3 37 305 20 0 20 0 4.6 0 4.9 4.4 10/05/2004 17:30:00 8.3 0.5 9.5 7.2 8.3 0.5 9.5 6.8 0.4 0 0.4 0.4 35 2 35 305 20 0 20 0 4.6 0 4.9 4.4 10/05/2004 17:40:00 7.9 0.5 9.1 6.5 8 0.6 9.5 6.5 0.4 0 0.4 0.4 36 3 35 305 20 0 20 0 4.7 0 4.9 4.7 10/05/2004 17:50:00 7.5 0.5 8.8 6.1 7.6 0.5 8.8 6.5 0.4 0 0.4 0.4 36 3 38 305 20 0 20 0 4.7 0 5.2 4.7 10/05/2004 18:00:00 8 0.5 9.1 6.8 8.1 0.5 9.1 6.8 0.4 0 0.4 0.4 37 3 37 305 20 0 20 0 4.7 0 5.2 4.7 10/05/2004 18:10:00 8.1 0.4 9.1 7.2 8.1 0.5 9.1 6.8 0.4 0 0.4 0.4 36 2 37 305 20 0 20 0 4.7 0 5.2 4.7 10/05/2004 18:20:00 8.1 0.4 9.1 6.8 8.2 0.4 9.1 7.2 0.4 0 0.4 0.4 35 2 35 305 20 0 20 0 4.7 0 5.2 4.7 10/05/2004 18:30:00 8.1 0.4 9.1 6.8 8.1 0.5 9.1 6.5 0.4 0 0.4 0.4 37 3 40 305 20 0 20 0 4.7 0 5.2 4.7 10/05/2004 18:40:00 8.2 0.5 9.5 6.5 8.2 0.5 9.5 6.8 0.4 0 0.4 0.4 40 3 40 305 20 0 20 0 4.8 0 5.2 4.7 10/05/2004 18:50:00 8.8 0.6 10.3 7.2 8.7 0.6 10.3 7.6 0.4 0 0.4 0.4 41 3 43 305 20 0 20 0 4.8 0 4.9 4.7 10/05/2004 19:00:00 8.9 0.5 9.9 7.6 8.9 0.5 9.9 7.6 0.4 0 0.4 0.4 42 3 44 305 20 0 20 0 4.8 0 5.2 4.7 10/05/2004 19:10:00 9.1 0.5 10.3 7.2 9 0.5 9.9 7.6 0.4 0 0.4 0.4 40 3 41 305 20 0 20 0 4.8 0 5.2 4.7 10/05/2004 19:20:00 9 0.6 10.7 7.6 9 0.7 10.7 7.2 0.4 0 0.4 0.4 40 3 38 305 20 0 20 0 4.8 0 5.2 4.7 10/05/2004 19:30:00 9.7 0.5 11.1 8 9.7 0.6 11.1 8 0.4 0 0.4 0.4 42 3 42 305 20 0 20 0 4.8 0 5.2 4.7 10/05/2004 19:40:00 9.5 0.7 11.1 8 9.5 0.8 11.1 8 0.4 0 0.4 0.4 41 3 40 305 20 0 20 0 4.8 0 5.2 4.7 10/05/2004 19:50:00 9.9 0.8 11.5 8 9.9 0.9 11.8 8 0.4 0 0.4 0.4 41 3 40 305 20 0 20 0 4.8 0 5.2 4.7 10/05/2004 20:00:00 10.6 0.6 11.8 8.8 10.5 0.6 11.8 8.8 0.4 0 0.4 0.4 43 3 44 305 19 0 20 0 4.8 0 5.4 4.7 10/05/2004 20:10:00 10.3 0.5 11.5 8.8 10.3 0.6 11.8 8.8 0.4 0 0.4 0.4 42 3 41 305 19 0 19 0 4.8 0 5.4 4.7 10/05/2004 20:20:00 10.1 0.5 11.1 8.8 10.2 0.6 11.5 8.4 0.4 0 0.4 0.4 44 3 48 305 19 0 19 0 4.8 0 5.2 4.7 10/05/2004 20:30:00 9.9 0.8 11.5 7.6 9.9 0.9 11.8 7.6 0.4 0 0.4 0.4 46 3 43 305 19 0 19 0 4.8 0 5.2 4.7 10/05/2004 20:40:00 9.7 0.7 11.1 7.2 9.7 0.8 11.1 7.2 0.4 0 0.4 0.4 45 3 44 305 19 0 19 0 4.7 0 5.2 4.7 10/05/2004 20:50:00 9.9 0.6 11.1 8 9.9 0.7 11.1 7.6 0.4 0 0.4 0.4 43 3 41 305 19 0 19 0 4.6 0.1 4.9 4.4 10/05/2004 21:00:00 9.7 0.7 11.1 7.2 9.7 0.8 11.1 6.8 0.4 0 0.4 0.4 46 3 46 305 19 0 19 0 4.5 0.1 4.9 4.4 10/05/2004 21:10:00 9.9 0.6 11.1 8.4 9.9 0.7 11.5 8 0.4 0 0.4 0.4 43 4 44 305 19 0 19 0 4.5 0.1 4.9 4.4 10/05/2004 21:20:00 10.1 0.5 11.5 9.1 10.2 0.6 11.8 8.8 0.4 0 0.4 0.4 42 3 40 305 19 0 19 0 4.4 0 4.9 4.4 10/05/2004 21:30:00 9.7 0.7 11.1 7.6 9.8 0.8 11.5 7.2 0.4 0 0.4 0.4 42 3 41 305 19 0 19 0 4.4 0 4.9 4.4 10/05/2004 21:40:00 9.3 0.5 10.3 7.6 9.4 0.5 10.3 8 0.4 0 0.4 0.4 43 3 44 305 19 0 19 0 4.4 0 4.9 4.2 10/05/2004 21:50:00 9.5 0.4 10.3 8.4 9.6 0.4 11.1 8.4 0.4 0 0.4 0.4 42 3 42 305 19 0 19 0 4.2 0 4.4 4.2 10/05/2004 22:00:00 9 0.6 10.3 7.6 9 0.7 10.7 6.8 0.4 0 0.4 0.4 41 3 39 305 19 0 19 0 4.3 0 4.7 4.2 10/05/2004 22:10:00 9 0.5 9.9 7.2 9.1 0.6 10.3 7.2 0.4 0 0.4 0.4 40 3 40 305 19 0 19 0 4.2 0 4.7 4.2 10/05/2004 22:20:00 8.9 0.6 10.3 7.2 9 0.7 10.7 7.6 0.4 0 0.4 0.4 40 4 33 305 19 0 19 0 4.2 0 4.7 4.2 10/05/2004 22:30:00 9.8 0.5 11.1 8.4 9.9 0.7 11.1 7.6 0.4 0 0.4 0.4 41 5 38 305 19 0 19 0 4 0 4.4 3.9 10/05/2004 22:40:00 9.4 0.7 10.7 7.6 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 40 4 39 305 18 0 18 0 4 0 4.7 3.9 10/05/2004 22:50:00 9.5 0.5 10.7 7.6 9.6 0.6 10.7 7.6 0.4 0 0.4 0.4 38 3 37 305 18 0 18 0 4 0 4.4 3.9 10/05/2004 23:00:00 9.9 0.5 11.1 8 9.9 0.6 11.5 8.4 0.4 0 0.4 0.4 40 4 43 305 18 0 18 0 4 0.1 4.4 3.9 10/05/2004 23:10:00 9.9 0.7 11.1 7.6 10 0.8 11.5 7.6 0.4 0 0.4 0.4 41 3 39 305 18 0 18 0 3.9 0.1 4.4 3.7 10/05/2004 23:20:00 9.6 0.5 11.1 8 9.8 0.6 11.1 8 0.4 0 0.4 0.4 39 4 42 305 18 0 18 0 3.9 0 4.4 3.7 10/05/2004 23:30:00 9.3 0.6 10.7 7.2 9.4 0.6 11.1 7.6 0.4 0 0.4 0.4 36 4 37 305 18 0 18 0 3.9 0.1 4.4 3.7 10/05/2004 23:40:00 9.7 0.5 11.1 8 9.8 0.6 11.5 8 0.4 0 0.4 0.4 35 4 35 305 18 0 18 0 3.9 0.1 4.4 3.7 10/05/2004 23:50:00 9.9 0.6 11.1 8 10 0.7 11.5 7.6 0.4 0 0.4 0.4 34 5 36 305 18 0 18 0 3.9 0.1 4.4 3.7 10/06/2004 00:00:00 10.3 0.5 11.1 8.4 10.4 0.6 11.5 8.8 0.4 0 0.4 0.4 32 3 33 305 18 0 18 0 3.8 0 4.4 3.7 10/06/2004 00:10:00 10 0.6 11.5 8.4 10.1 0.7 11.8 8 0.4 0 0.4 0.4 35 5 31 305 18 0 18 0 3.7 0 4.2 3.4 10/06/2004 00:20:00 9.9 0.6 11.5 8 10.1 0.6 11.5 8.4 0.4 0 0.4 0.4 33 3 27 305 18 0 18 0 3.7 0 4.2 3.4 10/06/2004 00:30:00 10.3 0.6 11.8 8.4 10.5 0.6 11.8 9.1 0.4 0 0.4 0.4 30 4 27 305 18 0 18 0 3.6 0.1 4.2 3.4 10/06/2004 00:40:00 10.4 0.6 11.5 8.8 10.5 0.6 11.8 8 0.4 0 0.4 0.4 30 4 26 305 18 0 18 0 3.5 0.1 4.2 3.4 10/06/2004 00:50:00 10.5 0.6 11.8 8.8 10.6 0.7 11.8 8.8 0.4 0 0.4 0.4 32 5 36 305 18 0 18 0 3.5 0.2 4.2 3.4 10/06/2004 01:00:00 10.1 0.7 11.8 8.4 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 32 4 34 305 18 0 18 0 3.5 0.1 4.2 3.4 10/06/2004 01:10:00 10.7 0.6 12.2 8.8 10.9 0.6 12.2 9.1 0.4 0 0.4 0.4 32 3 34 305 18 0 18 0 3.4 0.2 3.9 3.2 10/06/2004 01:20:00 11 0.6 12.2 9.1 11.1 0.7 12.6 9.1 0.4 0 0.4 0.4 33 4 32 305 18 0 18 0 3.3 0.1 3.7 3.2 10/06/2004 01:30:00 10.8 0.6 12.2 8.8 11 0.8 12.6 8.4 0.4 0 0.4 0.4 35 4 39 305 18 0 18 0 3.3 0.1 3.7 3.2 10/06/2004 01:40:00 11.3 0.6 12.6 9.5 11.5 0.7 13 9.1 0.4 0 0.4 0.4 35 3 39 305 18 0 18 0 3.3 0.1 3.7 3.2 10/06/2004 01:50:00 11 0.6 12.2 9.5 11.1 0.7 12.2 9.1 0.4 0 0.4 0.4 38 4 43 305 18 0 18 0 3.4 0.1 3.7 3.2 10/06/2004 02:00:00 11.2 0.8 13.3 9.1 11.3 0.9 13.3 9.1 0.4 0 0.4 0.4 41 4 47 305 17 0 18 0 3.4 0.1 3.7 3.2 10/06/2004 02:10:00 11.9 0.8 13.3 9.1 11.9 0.8 13.3 8.8 0.4 0 0.4 0.4 40 4 41 305 17 0 17 0 3.4 0.1 3.9 3.2 10/06/2004 02:20:00 11.2 0.6 12.6 9.5 11.3 0.7 12.6 9.1 0.4 0 0.4 0.4 39 3 41 305 17 0 17 0 3.4 0.1 3.9 3.4 10/06/2004 02:30:00 10.2 0.7 11.5 8.4 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 39 4 48 305 17 0 17 0 3.4 0.1 3.9 3.4 10/06/2004 02:40:00 10.6 0.5 11.8 9.1 10.8 0.6 12.2 8.8 0.4 0 0.4 0.4 38 3 40 305 17 0 17 0 3.4 0 3.9 3.2 10/06/2004 02:50:00 10.4 0.8 12.2 8 10.4 0.8 12.2 8 0.4 0 0.4 0.4 37 4 32 305 17 0 17 0 3.4 0 3.9 3.4 10/06/2004 03:00:00 10.2 0.8 11.8 7.2 10.3 0.8 12.2 8 0.4 0 0.4 0.4 39 4 40 305 17 0 17 0 3.4 0 3.7 3.2 10/06/2004 03:10:00 10.4 0.6 11.5 8.4 10.5 0.7 11.8 8 0.4 0 0.4 0.4 38 5 35 305 17 0 17 0 3.4 0 3.7 3.2 10/06/2004 03:20:00 10.2 0.5 11.5 8.8 10.3 0.5 11.8 8.8 0.4 0 0.4 0.4 35 5 43 305 17 0 17 0 3.4 0 3.7 3.2 10/06/2004 03:30:00 11.2 0.9 13 8.4 11.3 1 13.7 8.4 0.4 0 0.4 0.4 36 3 30 305 17 0 17 0 3.4 0 3.7 3.2 10/06/2004 03:40:00 11.5 0.6 12.6 9.5 11.6 0.7 13 9.5 0.4 0 0.4 0.4 35 4 31 305 16 0 16 0 3.4 0 3.7 3.4 10/06/2004 03:50:00 11.6 0.6 13.3 9.5 11.6 0.7 13.3 9.5 0.4 0 0.4 0.4 36 3 35 305 16 0 16 0 3.4 0 3.7 3.4 10/06/2004 04:00:00 11.2 0.8 12.6 8.8 11.2 0.8 13 8.8 0.4 0 0.4 0.4 36 3 36 305 16 0 16 0 3.5 0.1 3.9 3.4 10/06/2004 04:10:00 11.6 0.7 13.3 9.5 11.6 0.8 13.3 8.8 0.4 0 0.4 0.4 32 4 30 305 15 0 15 0 3.4 0.1 3.9 3.2 10/06/2004 04:20:00 11.4 0.6 13 9.5 11.4 0.6 13 9.5 0.4 0 0.4 0.4 34 3 33 305 15 0 15 0 3.4 0.1 3.9 3.2 10/06/2004 04:30:00 10.6 0.8 12.2 8.8 10.6 0.9 12.2 8.4 0.4 0 0.4 0.4 35 4 35 305 15 0 15 0 3.4 0.2 3.9 3.2 10/06/2004 04:40:00 10.7 0.7 12.2 9.1 10.7 0.8 12.2 8 0.4 0 0.4 0.4 34 4 39 305 15 0 15 0 3.4 0.1 3.9 3.2 10/06/2004 04:50:00 10.4 0.8 11.8 8.4 10.5 0.8 12.2 8 0.4 0 0.4 0.4 35 3 36 305 15 0 15 0 3.3 0.1 3.7 3.2 10/06/2004 05:00:00 10.3 0.8 12.2 8 10.3 0.9 12.2 8 0.4 0 0.4 0.4 34 3 37 305 14 0 15 0 3.3 0.1 3.7 3.2 10/06/2004 05:10:00 10.4 0.6 11.8 8.8 10.6 0.7 12.2 8.4 0.4 0 0.4 0.4 35 4 37 305 14 0 14 0 3.3 0.2 3.7 3.2 10/06/2004 05:20:00 10.3 0.8 11.8 7.6 10.4 0.8 12.2 8 0.4 0 0.4 0.4 34 4 31 305 14 0 14 0 3.4 0.2 3.7 3.2 10/06/2004 05:30:00 10.3 0.5 11.8 8.4 10.4 0.6 11.8 8.8 0.4 0 0.4 0.4 34 3 39 305 13 0 13 0 3.4 0.1 3.9 3.2 10/06/2004 05:40:00 10.5 0.6 11.8 8.8 10.6 0.6 11.8 8.8 0.4 0 0.4 0.4 34 3 30 305 13 0 13 0 3.4 0.2 3.7 3.2 10/06/2004 05:50:00 10.3 0.5 11.8 8.8 10.4 0.6 11.8 8.4 0.4 0 0.4 0.4 35 3 36 305 12 0 12 0 3.4 0.1 3.7 3.2 10/06/2004 06:00:00 9.8 0.6 11.5 8 9.9 0.7 11.5 8 0.4 0 0.4 0.4 34 5 39 305 12 0 12 0 3.4 0.1 3.9 3.2 10/06/2004 06:10:00 10 0.7 12.2 8 10.2 0.8 11.5 8 0.4 0 0.4 0.4 27 4 31 305 11 0 11 0 3.4 0.2 3.7 3.2 10/06/2004 06:20:00 10 0.5 11.1 8.8 10.1 0.5 11.1 8.8 0.4 0 0.4 0.4 31 3 31 305 11 0 11 0 3.4 0.2 3.7 3.2 10/06/2004 06:30:00 9.9 0.6 11.5 8 10 0.8 11.8 7.6 0.4 0 0.4 0.4 31 6 22 305 10 0 10 0 3.3 0 3.4 3.2 10/06/2004 06:40:00 9.7 0.5 11.1 8.4 9.9 0.6 11.5 7.6 0.4 0 0.4 0.4 29 4 27 305 10 0 10 0 3.3 0 3.7 3.2 10/06/2004 06:50:00 9.7 0.8 11.5 7.6 9.9 0.9 11.8 7.6 0.4 0 0.4 0.4 27 4 21 305 9 0 9 0 3.3 0 3.7 3.2 10/06/2004 07:00:00 9.3 0.6 10.7 7.6 9.5 0.6 11.1 8 0.4 0 0.4 0.4 28 3 32 305 9 0 9 0 3.3 0 3.7 3.2 10/06/2004 07:10:00 9.3 0.6 10.7 8 9.4 0.7 10.7 7.6 0.4 0 0.4 0.4 30 3 29 305 9 0 9 0 3.2 0 3.4 3.2 10/06/2004 07:20:00 9.4 0.6 10.7 7.6 9.6 0.7 11.1 7.6 0.4 0 0.4 0.4 31 5 33 305 9 0 9 0 3.2 0 3.7 2.9 10/06/2004 07:30:00 9.2 0.6 11.1 7.6 9.2 0.7 11.1 7.6 0.4 0 0.4 0.4 32 5 36 305 9 0 9 0 3.2 0 3.7 3.2 10/06/2004 07:40:00 9.6 0.6 11.1 8 9.7 0.7 11.1 8 0.4 0 0.4 0.4 29 4 31 305 9 0 9 0 3.2 0 3.7 2.9 10/06/2004 07:50:00 9.3 0.5 10.7 8 9.4 0.6 10.7 7.6 0.4 0 0.4 0.4 32 3 31 305 9 0 8 0 3.1 0 3.7 2.9 10/06/2004 08:00:00 8.9 0.5 10.3 8 9.1 0.6 10.7 7.6 0.4 0 0.4 0.4 31 3 28 305 9 0 8 0 3.1 0 3.7 2.9 10/06/2004 08:10:00 8.5 0.6 9.9 7.2 8.7 0.7 9.9 6.8 0.4 0 0.4 0.4 33 3 30 305 9 0 9 0 3 0 3.7 2.9 10/06/2004 08:20:00 8.3 0.5 9.5 6.8 8.4 0.6 9.9 6.5 0.4 0 0.4 0.4 32 5 33 305 10 0 10 0 3.1 0 3.7 2.9 10/06/2004 08:30:00 8.4 0.5 9.5 6.8 8.5 0.5 9.5 6.8 0.4 0 0.4 0.4 33 5 42 305 10 0 10 0 3.1 0 3.7 2.9 10/06/2004 08:40:00 8.6 0.6 10.3 6.8 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 34 4 37 305 10 0 10 0 3.1 0 3.7 2.9 10/06/2004 08:50:00 8.6 0.5 9.5 7.2 8.7 0.5 9.9 6.8 0.4 0 0.4 0.4 33 5 32 305 10 0 10 0 3.1 0 3.7 2.9 10/06/2004 09:00:00 8.4 0.7 9.5 6.1 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 33 3 35 305 10 0 10 0 3.2 0 3.7 2.9 10/06/2004 09:10:00 8 0.6 9.5 6.5 8.2 0.6 9.9 6.8 0.4 0 0.4 0.4 32 4 31 305 10 0 10 0 3.2 0.1 3.7 2.9 10/06/2004 09:20:00 8.1 0.6 9.5 6.5 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 28 6 32 305 10 0 10 0 3.2 0 3.7 3.2 10/06/2004 09:30:00 7.6 0.5 9.1 5.7 7.7 0.5 9.1 6.1 0.4 0 0.4 0.4 28 4 26 305 10 0 10 0 3.2 0 3.7 2.9 10/06/2004 09:40:00 7.6 0.5 9.1 6.5 7.8 0.5 9.1 6.5 0.4 0 0.4 0.4 24 5 29 305 10 0 10 0 3.2 0.1 3.7 2.9 10/06/2004 09:50:00 7.9 0.5 9.1 6.1 8.1 0.5 9.1 6.5 0.4 0 0.4 0.4 25 5 27 305 10 0 10 0 3.3 0.1 3.7 3.2 10/06/2004 10:00:00 8 0.6 10.3 6.8 8.1 0.7 10.3 6.5 0.4 0 0.4 0.4 23 5 17 305 10 0 10 0 3.4 0.1 3.9 3.2 10/06/2004 10:10:00 8 0.6 9.5 6.1 8.1 0.7 9.5 6.5 0.4 0 0.4 0.4 20 5 25 305 9 0 9 0 3.3 0.1 3.7 3.2 10/06/2004 10:20:00 8.2 0.6 9.5 6.5 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 22 4 33 305 9 0 9 0 3.3 0.1 3.7 3.2 10/06/2004 10:30:00 8 0.6 9.5 6.1 8.2 0.7 9.9 5.7 0.4 0 0.4 0.4 24 4 26 305 8 0 8 0 3.3 0.1 3.7 3.2 10/06/2004 10:40:00 7.7 0.5 8.8 6.1 7.9 0.5 9.1 6.5 0.4 0 0.4 0.4 28 4 31 305 8 0 8 0 3.4 0.2 3.9 3.2 10/06/2004 10:50:00 7.6 0.5 8.8 6.5 7.8 0.5 9.1 6.5 0.4 0 0.4 0.4 25 4 23 305 7 0 8 0 3.3 0.1 3.7 3.2 10/06/2004 11:00:00 7.4 0.4 8.4 6.1 7.6 0.4 8.8 6.5 0.4 0 0.4 0.4 19 6 27 305 7 0 7 0 3.4 0 3.7 3.2 10/06/2004 11:10:00 7.1 0.4 8 5.7 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 17 4 23 305 6 0 7 0 3.3 0.1 3.7 3.2 10/06/2004 11:20:00 7.1 0.5 8.4 5.7 7.2 0.5 8.4 6.1 0.4 0 0.4 0.4 16 5 12 305 6 0 6 0 3.3 0 3.7 3.2 10/06/2004 11:30:00 7.5 0.5 8.8 6.5 7.7 0.5 9.1 5.7 0.4 0 0.4 0.4 22 4 22 305 5 0 5 0 3.3 0 3.7 3.2 10/06/2004 11:40:00 7.8 0.5 9.1 6.5 8 0.5 9.5 6.5 0.4 0 0.4 0.4 22 4 25 305 5 0 5 0 3.3 0 3.7 3.2 10/06/2004 11:50:00 7.7 0.6 9.1 6.5 7.8 0.6 9.1 6.5 0.4 0 0.4 0.4 22 5 20 305 5 0 5 0 3.3 0 3.7 3.2 10/06/2004 12:00:00 8 0.5 9.1 6.5 8.1 0.5 9.5 6.8 0.4 0 0.4 0.4 19 5 28 305 4 0 4 0 3.4 0.1 3.7 3.2 10/06/2004 12:10:00 7 0.5 8.4 5.7 7.2 0.6 8.4 5.7 0.4 0 0.4 0.4 20 5 19 305 4 0 4 0 3.4 0.1 3.7 3.2 10/06/2004 12:20:00 7.3 0.4 8.4 6.1 7.5 0.5 8.4 5.7 0.4 0 0.4 0.4 14 4 13 305 4 0 4 0 3.4 0.1 3.7 3.2 10/06/2004 12:30:00 7.5 0.4 8.4 6.5 7.7 0.5 8.8 6.1 0.4 0 0.4 0.4 19 5 19 305 4 0 4 0 3.4 0.1 3.7 3.2 10/06/2004 12:40:00 7.1 0.5 8 5.7 7.3 0.5 8.4 6.1 0.4 0 0.4 0.4 18 4 15 305 4 0 4 0 3.4 0.1 3.9 3.2 10/06/2004 12:50:00 7.1 0.6 8.8 5.7 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 19 5 24 305 3 0 4 0 3.4 0 3.9 3.2 10/06/2004 13:00:00 7.2 0.6 8.4 5.7 7.4 0.6 8.8 5.3 0.4 0 0.4 0.4 16 4 16 305 4 0 4 0 3.5 0 4.2 3.4 10/06/2004 13:10:00 7.3 0.5 8.8 6.1 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 18 5 26 305 3 0 3 0 3.5 0.1 4.2 3.4 10/06/2004 13:20:00 7.5 0.5 8.4 6.1 7.7 0.5 8.8 6.5 0.4 0 0.4 0.4 21 5 17 305 3 0 4 0 3.6 0.2 4.2 3.4 10/06/2004 13:30:00 7.3 0.4 8.4 6.5 7.4 0.4 8.8 6.5 0.4 0 0.4 0.4 24 4 29 305 3 0 4 0 3.5 0.1 4.2 3.4 10/06/2004 13:40:00 7.3 0.6 8.4 5.7 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 24 4 32 305 3 0 3 0 3.6 0.2 4.2 3.4 10/06/2004 13:50:00 7.1 0.4 8.4 5.7 7.3 0.5 8.4 6.1 0.4 0 0.4 0.4 22 5 22 305 3 0 3 0 3.6 0 4.2 3.4 10/06/2004 14:00:00 6.9 0.5 8 4.9 7.1 0.5 8.4 6.1 0.4 0 0.4 0.4 18 5 22 305 3 0 3 0 3.6 0.1 4.2 3.4 10/06/2004 14:10:00 6.8 0.4 7.6 5.7 7 0.4 8 5.7 0.4 0 0.4 0.4 11 4 14 305 3 0 3 0 3.4 0.2 4.2 3.2 10/06/2004 14:20:00 6.4 0.4 7.2 4.9 6.6 0.4 7.6 5.3 0.4 0 0.4 0.4 15 3 19 305 3 0 3 0 3.4 0.2 3.9 3.2 10/06/2004 14:30:00 6.4 0.4 7.2 5.3 6.6 0.4 7.6 5.3 0.4 0 0.4 0.4 15 3 13 305 3 0 3 0 3.4 0.2 3.9 3.2 10/06/2004 14:40:00 6.5 0.4 7.6 5.3 6.7 0.4 7.6 5.7 0.4 0 0.4 0.4 16 3 20 305 3 0 3 0 3.4 0.2 3.9 3.2 10/06/2004 14:50:00 6.6 0.5 7.6 4.9 6.8 0.5 8 5.7 0.4 0 0.4 0.4 21 3 17 305 3 0 2 0 3.3 0.1 3.7 3.2 10/06/2004 15:00:00 6.4 0.4 7.6 5.7 6.7 0.4 7.6 5.3 0.4 0 0.4 0.4 25 4 25 305 3 0 2 0 3.2 0.1 3.7 2.9 10/06/2004 15:10:00 6.5 0.4 7.6 5.3 6.7 0.5 7.6 5.3 0.4 0 0.4 0.4 25 3 21 305 3 0 3 0 3.3 0.1 3.7 3.2 10/06/2004 15:20:00 6.2 0.6 7.6 4.9 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 21 5 22 305 3 0 3 0 3.4 0.2 3.9 3.2 10/06/2004 15:30:00 7 0.5 8.8 5.7 7.2 0.5 8.8 6.1 0.4 0 0.4 0.4 20 4 20 305 3 0 3 0 3.6 0 4.2 3.4 10/06/2004 15:40:00 6.6 0.5 8 4.6 6.8 0.6 8 4.9 0.4 0 0.4 0.4 22 3 22 305 3 0 3 0 3.6 0 4.2 3.4 10/06/2004 15:50:00 6.9 0.5 8.4 5.7 7.1 0.6 8.8 5.7 0.4 0 0.4 0.4 19 5 22 305 3 0 3 0 3.7 0 3.9 3.4 10/06/2004 16:00:00 6.5 0.4 7.6 5.7 6.7 0.4 8 5.3 0.4 0 0.4 0.4 20 4 21 305 3 0 3 0 3.7 0 4.2 3.7 10/06/2004 16:10:00 6.5 0.6 8 4.9 6.7 0.7 8.4 4.9 0.4 0 0.4 0.4 14 4 18 305 3 0 2 0 3.8 0 4.2 3.7 10/06/2004 16:20:00 6.7 0.5 8 5.3 6.9 0.5 8.8 5.7 0.4 0 0.4 0.4 15 4 14 305 2 0 2 0 3.8 0 4.4 3.7 10/06/2004 16:30:00 6.9 0.6 8 5.3 7.1 0.6 8.4 5.3 0.4 0 0.4 0.4 8 3 15 305 2 0 2 0 3.9 0 4.4 3.7 10/06/2004 16:40:00 7.1 0.5 8.4 6.1 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 16 3 23 305 2 0 2 0 3.9 0 4.4 3.7 10/06/2004 16:50:00 6.7 0.5 8 5.3 6.8 0.5 8.4 5.3 0.4 0 0.4 0.4 15 4 17 305 2 0 2 0 3.9 0.1 4.4 3.7 10/06/2004 17:00:00 6.8 0.5 8 5.7 7 0.5 8.4 5.7 0.4 0 0.4 0.4 9 3 18 305 2 0 2 0 4 0.1 4.7 3.9 10/06/2004 17:10:00 7 0.5 8 6.1 7.3 0.5 8.4 6.1 0.4 0 0.4 0.4 9 3 9 305 2 0 2 0 4 0 4.4 3.9 10/06/2004 17:20:00 7.3 0.5 8.4 6.1 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 8 3 12 305 2 0 2 0 4 0 4.7 3.9 10/06/2004 17:30:00 7.6 0.5 8.4 6.5 7.9 0.5 8.8 6.5 0.4 0 0.4 0.4 7 3 6 305 1 0 1 0 4 0 4.4 4.2 10/06/2004 17:40:00 7.2 0.6 8.4 5.3 7.5 0.6 8.8 5.7 0.4 0 0.4 0.4 9 3 8 305 1 0 1 0 4 0 4.7 3.9 10/06/2004 17:50:00 7.2 0.4 8.4 6.1 7.5 0.5 8.4 6.1 0.4 0 0.4 0.4 7 3 2 305 1 0 1 0 4 0 4.7 4.2 10/06/2004 18:00:00 7.1 0.5 8.4 5.7 7.4 0.5 8.8 5.7 0.4 0 0.4 0.4 5 4 4 305 1 0 1 0 4.1 0.1 4.7 3.9 10/06/2004 18:10:00 6.5 0.4 7.6 5.3 6.7 0.5 8 5.3 0.4 0 0.4 0.4 12 3 12 305 1 0 1 0 4.1 0.1 4.7 3.9 10/06/2004 18:20:00 6.8 0.4 8 5.3 7.1 0.4 8.4 5.7 0.4 0 0.4 0.4 13 3 11 305 1 0 1 0 4 0.1 4.4 3.9 10/06/2004 18:30:00 6.9 0.6 8 5.3 7.1 0.6 8 5.3 0.4 0 0.4 0.4 13 3 10 305 1 0 1 0 4 0.2 4.4 3.9 10/06/2004 18:40:00 6.8 0.5 8 5.3 7 0.6 8 5.3 0.4 0 0.4 0.4 11 3 13 305 1 0 1 0 4 0.1 4.4 3.9 10/06/2004 18:50:00 6.6 0.5 7.6 4.9 6.8 0.5 8 5.3 0.4 0 0.4 0.4 16 3 17 305 1 0 1 0 4 0.1 4.4 3.9 10/06/2004 19:00:00 6.5 0.4 7.6 5.3 6.8 0.4 7.6 5.7 0.4 0 0.4 0.4 18 4 25 305 1 0 1 0 4 0.1 4.7 3.9 10/06/2004 19:10:00 6.4 0.5 7.2 4.9 6.6 0.5 8 5.3 0.4 0 0.4 0.4 19 3 19 305 1 0 1 0 4.1 0.1 4.7 3.9 10/06/2004 19:20:00 6.5 0.4 7.6 5.7 6.8 0.4 8 5.7 0.4 0 0.4 0.4 18 3 19 305 1 0 1 0 4.1 0.1 4.7 3.9 10/06/2004 19:30:00 6.3 0.5 7.2 5.3 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 16 3 17 305 1 0 1 0 4.1 0.1 4.7 3.9 10/06/2004 19:40:00 6.3 0.4 7.2 5.3 6.6 0.4 7.6 5.3 0.4 0 0.4 0.4 14 3 11 305 1 0 1 0 4.1 0.1 4.7 3.9 10/06/2004 19:50:00 6.2 0.5 7.2 4.6 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 14 3 17 305 1 0 1 0 4.1 0.1 4.7 4.2 10/06/2004 20:00:00 5.7 0.5 6.8 4.2 6.1 0.4 7.2 4.9 0.4 0 0.4 0.4 10 3 13 305 1 0 1 0 4.1 0.1 4.7 4.2 10/06/2004 20:10:00 5.6 0.4 6.5 4.2 5.9 0.4 6.8 4.9 0.4 0 0.4 0.4 11 3 12 305 1 0 1 0 4 0 4.7 3.9 10/06/2004 20:20:00 5.7 0.4 6.5 4.6 6 0.4 7.2 4.9 0.4 0 0.4 0.4 12 3 3 305 1 0 1 0 4 0 4.7 3.9 10/06/2004 20:30:00 5.7 0.4 6.8 4.6 6 0.4 6.8 4.9 0.4 0 0.4 0.4 11 3 10 305 1 0 1 0 4 0 4.7 3.9 10/06/2004 20:40:00 5.6 0.4 6.5 4.6 5.9 0.4 6.8 4.6 0.4 0 0.4 0.4 9 3 7 305 1 0 1 0 4.1 0 4.7 4.2 10/06/2004 20:50:00 5.8 0.4 6.8 4.6 6.1 0.4 7.2 5.3 0.4 0 0.4 0.4 9 2 10 305 1 0 1 0 4.1 0 4.7 4.2 10/06/2004 21:00:00 6.1 0.5 7.2 4.9 6.3 0.5 7.6 4.9 0.4 0 0.4 0.4 7 3 2 305 1 0 1 0 4 0 4.7 4.2 10/06/2004 21:10:00 6 0.5 6.8 4.2 6.3 0.5 7.6 4.6 0.4 0 0.4 0.4 5 3 4 305 1 0 1 0 4 0 4.7 3.9 10/06/2004 21:20:00 6.2 0.4 7.2 4.9 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 10 3 10 305 1 0 1 0 4 0 4.4 3.9 10/06/2004 21:30:00 6.2 0.5 7.2 4.9 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 8 3 7 305 1 0 1 0 4 0 4.4 3.9 10/06/2004 21:40:00 6.1 0.4 7.2 4.9 6.4 0.4 7.6 5.3 0.4 0 0.4 0.4 11 3 10 305 1 0 1 0 4 0 4.4 3.9 10/06/2004 21:50:00 6.2 0.4 7.2 4.6 6.4 0.4 7.2 4.9 0.4 0 0.4 0.4 11 4 11 305 1 0 1 0 3.9 0.1 4.4 3.7 10/06/2004 22:00:00 6 0.5 6.8 4.9 6.3 0.4 7.2 5.3 0.4 0 0.4 0.4 11 3 16 305 1 0 1 0 3.9 0.1 4.4 3.9 10/06/2004 22:10:00 6.1 0.3 6.8 5.3 6.3 0.4 7.2 4.9 0.4 0 0.4 0.4 11 3 9 305 1 0 1 0 3.9 0.1 4.4 3.9 10/06/2004 22:20:00 5.8 0.4 6.8 4.6 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 11 3 13 305 1 0 1 0 3.9 0.1 4.4 3.7 10/06/2004 22:30:00 5.8 0.4 6.5 4.6 6.1 0.4 6.8 4.9 0.4 0 0.4 0.4 12 3 9 305 1 0 1 0 3.9 0.1 4.4 3.7 10/06/2004 22:40:00 5.7 0.4 6.5 4.9 6.1 0.4 6.8 4.9 0.4 0 0.4 0.4 12 4 17 305 1 0 1 0 3.9 0.1 4.4 3.7 10/06/2004 22:50:00 5.7 0.4 6.8 4.6 6 0.4 6.8 4.9 0.4 0 0.4 0.4 12 3 8 305 1 0 1 0 3.9 0.1 4.4 3.7 10/06/2004 23:00:00 5.5 0.4 6.5 4.2 5.9 0.4 7.2 4.6 0.4 0 0.4 0.4 13 2 13 305 1 0 1 0 3.9 0.1 4.4 3.7 10/06/2004 23:10:00 5.2 0.3 6.1 4.2 5.6 0.3 6.5 4.6 0.4 0 0.4 0.4 12 3 7 305 1 0 1 0 3.9 0.1 4.4 3.7 10/06/2004 23:20:00 5.3 0.4 6.1 4.2 5.6 0.3 6.5 4.9 0.4 0 0.4 0.4 17 3 18 305 1 0 1 0 3.9 0.2 4.4 3.7 10/06/2004 23:30:00 5.7 0.4 6.8 4.6 6 0.4 6.8 4.9 0.4 0 0.4 0.4 18 4 20 305 1 0 1 0 3.9 0.1 4.4 3.7 10/06/2004 23:40:00 5.2 0.4 6.5 4.2 5.6 0.4 6.5 4.6 0.4 0 0.4 0.4 19 3 16 305 1 0 1 0 3.8 0.1 4.4 3.7 10/06/2004 23:50:00 4.8 0.4 5.7 3.8 5.2 0.3 6.1 4.2 0.4 0 0.4 0.4 19 4 18 305 1 0 1 0 3.8 0 4.4 3.7 10/07/2004 00:00:00 4.4 0.3 4.9 3.4 4.9 0.3 5.7 3.8 0.4 0 0.4 0.4 19 3 21 305 1 0 1 0 3.8 0 4.2 3.7 10/07/2004 00:10:00 4.4 0.4 4.9 3.4 4.8 0.4 5.3 3.8 0.4 0 0.4 0.4 19 4 16 305 1 0 1 0 3.9 0.1 4.4 3.7 10/07/2004 00:20:00 4.6 0.4 5.7 3.8 5 0.4 5.7 4.2 0.4 0 0.4 0.4 24 4 27 305 1 0 1 0 3.8 0.1 4.2 3.7 10/07/2004 00:30:00 4.4 0.4 5.3 3.4 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 25 3 26 305 1 0 1 0 3.8 0.1 4.2 3.7 10/07/2004 00:40:00 4.2 0.5 5.3 2.6 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 22 6 28 305 1 0 1 0 3.8 0.1 4.2 3.7 10/07/2004 00:50:00 4.9 0.4 5.7 3.8 5.3 0.3 6.1 4.6 0.4 0 0.4 0.4 15 4 14 305 1 0 1 0 3.7 0 4.2 3.4 10/07/2004 01:00:00 5 0.5 6.1 3.8 5.4 0.5 6.5 4.2 0.4 0 0.4 0.4 17 5 11 305 1 0 1 0 3.7 0 4.2 3.4 10/07/2004 01:10:00 4.6 0.5 5.7 3.4 5 0.4 6.1 3.8 0.4 0 0.4 0.4 16 3 16 305 1 0 1 0 3.7 0 4.2 3.4 10/07/2004 01:20:00 4.5 0.4 5.3 3.4 5 0.4 5.7 4.2 0.4 0 0.4 0.4 14 4 17 305 1 0 1 0 3.6 0.1 4.2 3.4 10/07/2004 01:30:00 4.2 0.3 4.9 3.4 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 16 3 19 305 1 0 1 0 3.6 0.1 4.2 3.4 10/07/2004 01:40:00 4.5 0.3 4.9 3.8 4.9 0.3 5.3 4.2 0.4 0 0.4 0.4 19 3 19 305 1 0 1 0 3.6 0.2 4.2 3.4 10/07/2004 01:50:00 4.2 0.4 4.9 2.6 4.6 0.4 5.3 3 0.4 0 0.4 0.4 20 3 22 305 1 0 1 0 3.5 0.1 4.2 3.4 10/07/2004 02:00:00 3.9 0.4 4.6 3 4.4 0.4 4.9 3.4 0.4 0 0.4 0.4 20 4 23 305 1 0 1 0 3.5 0.2 4.2 3.4 10/07/2004 02:10:00 3.8 0.3 4.6 2.6 4.3 0.3 4.9 3.4 0.4 0 0.4 0.4 24 5 25 305 1 0 1 0 3.5 0.2 4.2 3.4 10/07/2004 02:20:00 3.8 0.3 4.6 3 4.2 0.3 4.9 3.4 0.4 0 0.4 0.4 26 3 34 305 1 0 1 0 3.4 0.2 3.9 3.2 10/07/2004 02:30:00 3 0.3 3.8 2.3 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 28 4 24 305 1 0 1 0 3.4 0.2 3.9 3.2 10/07/2004 02:40:00 2.6 0.3 3.4 1.9 3.2 0.2 3.8 2.6 0.4 0 0.4 0.4 32 3 35 305 1 0 1 0 3.4 0.2 3.9 3.4 10/07/2004 02:50:00 2.4 0.3 3 1.5 2.9 0.3 3.4 1.9 0.4 0 0.4 0.4 29 3 31 305 1 0 1 0 3.4 0.1 3.9 3.4 10/07/2004 03:00:00 2.3 0.3 3 1.5 2.9 0.3 3.4 2.3 0.4 0 0.4 0.4 36 5 35 305 1 0 1 0 3.4 0.2 3.9 3.2 10/07/2004 03:10:00 1.9 0.4 2.6 0.7 2.6 0.3 3.4 1.9 0.4 0 0.4 0.4 33 6 40 305 1 0 1 0 3.4 0.2 3.9 3.2 10/07/2004 03:20:00 1.9 0.3 2.3 1.1 2.6 0.2 3 1.9 0.4 0 0.4 0.4 27 3 25 305 1 0 1 0 3.4 0.2 3.9 3.2 10/07/2004 03:30:00 2.2 0.3 3 1.5 2.8 0.2 3.4 2.3 0.4 0 0.4 0.4 26 7 19 305 1 0 1 0 3.4 0.2 3.9 3.2 10/07/2004 03:40:00 2.4 0.3 3 1.5 3 0.2 3.4 2.3 0.4 0 0.4 0.4 20 3 21 305 2 0 1 0 3.4 0.1 3.9 3.2 10/07/2004 03:50:00 2.1 0.4 3 1.1 2.6 0.3 3 1.9 0.4 0 0.4 0.4 21 2 22 305 2 0 2 0 3.3 0.2 3.7 3.2 10/07/2004 04:00:00 1.1 0.4 2.3 0.4 1.9 0.2 2.3 1.5 0.4 0 0.4 0.4 21 3 22 305 2 0 2 0 3.3 0.1 3.7 3.2 10/07/2004 04:10:00 0.4 0.1 0.7 0.4 1.3 0.3 1.9 0.7 0.4 0 0.4 0.4 23 4 23 305 2 0 2 0 3.2 0.1 3.7 2.9 10/07/2004 04:20:00 0.4 0.1 1.1 0.4 1.2 0.3 1.9 0.4 0.4 0 0.4 0.4 25 4 21 305 2 0 2 0 2.8 0.1 3.4 2.7 10/07/2004 04:30:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 22 6 24 305 2 0 2 0 2.7 0 3.2 2.5 10/07/2004 04:40:00 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 0.4 0 0.4 0.4 25 3 26 305 2 0 2 0 2.7 0 3.2 2.5 10/07/2004 04:50:00 1 0.3 1.9 0.4 1.4 0.3 1.9 0.4 0.4 0 0.4 0.4 24 6 16 305 2 0 2 0 2.7 0 3.2 2.7 10/07/2004 05:00:00 1.6 0.4 2.3 0.7 2.1 0.3 2.6 1.5 0.4 0 0.4 0.4 27 3 32 305 3 0 3 0 3 0.2 3.7 2.7 10/07/2004 05:10:00 1.2 0.4 2.3 0.4 1.8 0.3 2.6 1.1 0.4 0 0.4 0.4 21 4 19 305 3 0 3 0 3.3 0.1 3.9 3.2 10/07/2004 05:20:00 0.4 0.2 1.5 0.4 1 0.4 1.9 0.4 0.4 0 0.4 0.4 52 13 26 305 3 0 3 0 3.3 0.1 3.9 3.2 10/07/2004 05:30:00 0.6 0.4 1.9 0.4 1.3 0.3 1.9 0.7 0.4 0 0.4 0.4 71 11 64 305 3 0 3 0 3.2 0 3.7 3.2 10/07/2004 05:40:00 0.4 0.2 1.1 0.4 0.9 0.3 1.9 0.4 0.4 0 0.4 0.4 72 12 62 305 3 0 3 0 3 0 3.7 2.9 10/07/2004 05:50:00 0.9 0.8 3 0.4 1.2 0.8 3.4 0.4 0.4 0 0.4 0.4 30 11 59 305 3 0 3 0 2.9 0.1 3.4 2.7 10/07/2004 06:00:00 1.8 0.5 2.6 0.7 2.3 0.4 3 1.5 0.4 0 0.4 0.4 38 3 52 305 3 0 4 0 3.1 0.1 3.7 2.9 10/07/2004 06:10:00 0.6 0.3 1.5 0.4 1.5 0.3 1.9 0.7 0.4 0 0.4 0.4 36 3 37 305 4 0 4 0 3 0 3.4 2.9 10/07/2004 06:20:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 34 0 305 305 4 0 4 0 2.9 0 3.4 2.9 10/07/2004 06:30:00 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 56 17 305 305 4 0 4 0 2.8 0.1 3.4 2.7 10/07/2004 06:40:00 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 69 0 305 305 5 0 5 0 2.6 0 3.2 2.5 10/07/2004 06:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 69 2 305 305 5 0 5 0 2.5 0 3.2 2.5 10/07/2004 07:00:00 0.6 0.4 1.5 0.4 1.2 0.4 1.9 0.4 0.4 0 0.4 0.4 30 8 26 305 5 0 5 0 2.6 0.1 3.2 2.5 10/07/2004 07:10:00 0.4 0.2 1.5 0.4 0.9 0.3 1.9 0.4 0.4 0 0.4 0.4 25 1 29 305 5 0 6 0 2.7 0 3.2 2.5 10/07/2004 07:20:00 1.3 0.3 1.9 0.7 1.8 0.2 2.3 1.5 0.4 0 0.4 0.4 33 5 29 305 6 0 6 0 2.6 0 3.2 2.5 10/07/2004 07:30:00 1.1 0.3 1.9 0.7 1.6 0.2 2.3 1.1 0.4 0 0.4 0.4 50 3 49 305 7 0 6 0 2.5 0.1 2.9 2.5 10/07/2004 07:40:00 1.8 0.3 2.6 1.1 2.1 0.2 2.6 1.5 0.4 0 0.4 0.4 51 1 53 305 7 0 7 0 2.5 0.1 2.9 2.2 10/07/2004 07:50:00 1.3 0.5 2.3 0.4 1.7 0.3 2.3 1.1 0.4 0 0.4 0.4 50 4 52 305 7 0 7 0 2.4 0.1 2.9 2.2 10/07/2004 08:00:00 2.4 0.5 3.4 1.5 2.6 0.5 3.4 1.5 0.4 0 0.4 0.4 52 5 50 305 7 0 7 0 2.3 0 2.7 2.2 10/07/2004 08:10:00 3.8 0.4 4.6 3 4 0.4 4.9 3 0.4 0 0.4 0.4 36 5 36 305 7 0 7 0 2.6 0 3.2 2.5 10/07/2004 08:20:00 4 0.3 4.6 3 4.2 0.3 4.9 3.4 0.4 0 0.4 0.4 37 4 38 305 8 0 8 0 2.6 0 2.9 2.5 10/07/2004 08:30:00 4.3 0.3 4.9 3.8 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 42 3 33 305 8 0 8 0 2.6 0 3.2 2.5 10/07/2004 08:40:00 4.5 0.3 5.3 3.8 4.7 0.3 5.7 3.8 0.4 0 0.4 0.4 41 3 41 305 8 0 8 0 2.7 0 3.2 2.7 10/07/2004 08:50:00 4.7 0.3 5.3 3.8 5 0.3 5.7 3.8 0.4 0 0.4 0.4 38 3 37 305 8 0 8 0 2.8 0.1 3.4 2.7 10/07/2004 09:00:00 4.5 0.4 5.3 3.4 4.7 0.4 5.3 3.8 0.4 0 0.4 0.4 37 3 35 305 7 0 7 0 2.8 0.1 3.2 2.7 10/07/2004 09:10:00 4.3 0.3 4.9 3.8 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 37 3 43 305 7 0 7 0 2.8 0.1 3.4 2.7 10/07/2004 09:20:00 4.3 0.3 4.9 3.4 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 37 2 38 305 6 0 7 0 2.9 0.1 3.4 2.7 10/07/2004 09:30:00 3.8 0.2 4.6 3 4.1 0.3 4.6 3.4 0.4 0 0.4 0.4 41 3 38 305 6 0 6 0 2.8 0.1 3.2 2.7 10/07/2004 09:40:00 3.8 0.3 4.6 3 4.1 0.3 4.6 3.4 0.4 0 0.4 0.4 37 3 38 305 6 0 6 0 2.9 0.1 3.4 2.7 10/07/2004 09:50:00 3.5 0.3 4.2 2.6 3.8 0.3 4.6 3 0.4 0 0.4 0.4 39 4 43 305 5 0 5 0 2.9 0 3.4 2.9 10/07/2004 10:00:00 3.8 0.3 4.2 3 4 0.3 4.6 3 0.4 0 0.4 0.4 38 3 39 305 5 0 5 0 3 0 3.4 2.9 10/07/2004 10:10:00 3.8 0.3 4.6 3 4 0.3 4.9 3 0.4 0 0.4 0.4 45 4 40 305 5 0 5 0 3 0 3.4 2.9 10/07/2004 10:20:00 4 0.3 4.6 3.4 4.1 0.3 4.9 3.4 0.4 0 0.4 0.4 51 4 48 305 4 0 4 0 3.1 0 3.7 2.9 10/07/2004 10:30:00 3.7 0.4 4.6 3 3.8 0.4 4.6 2.6 0.4 0 0.4 0.4 62 7 51 305 4 0 4 0 3.2 0 3.4 3.2 10/07/2004 10:40:00 3.7 0.4 4.6 2.6 3.7 0.3 4.6 2.6 0.4 0 0.4 0.4 63 3 64 305 3 0 3 0 3.2 0 3.7 3.2 10/07/2004 10:50:00 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.6 0.4 0 0.4 0.4 61 3 58 305 3 0 3 0 3.4 0.1 3.9 3.2 10/07/2004 11:00:00 3.4 0.4 4.2 2.3 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 61 4 64 305 2 0 2 0 3.5 0.1 3.9 3.4 10/07/2004 11:10:00 3.3 0.4 4.2 2.6 3.5 0.4 4.2 2.6 0.4 0 0.4 0.4 66 4 67 305 2 0 2 0 3.6 0 4.2 3.4 10/07/2004 11:20:00 2.9 0.4 3.8 1.5 3 0.4 3.8 2.3 0.4 0 0.4 0.4 71 9 68 305 2 0 2 0 3.7 0 4.2 3.7 10/07/2004 11:30:00 3.4 0.4 4.6 2.3 3.4 0.4 4.2 2.3 0.4 0 0.4 0.4 79 8 89 305 1 0 1 0 3.9 0 4.4 3.7 10/07/2004 11:40:00 3.8 0.5 4.9 2.6 3.8 0.4 5.3 2.6 0.4 0 0.4 0.4 77 7 77 305 1 0 1 0 4 0.1 4.4 3.9 10/07/2004 11:50:00 4 0.5 5.3 2.3 4.1 0.5 5.3 2.6 0.4 0 0.4 0.4 79 7 78 305 1 0 1 0 4.1 0 4.4 3.9 10/07/2004 12:00:00 4.2 0.9 5.7 1.1 4.2 0.8 5.7 1.5 0.4 0 0.4 0.4 75 10 69 305 1 0 1 0 4.2 0.1 4.7 4.2 10/07/2004 12:10:00 3.4 1.2 6.1 0.4 3.6 1 5.7 1.5 0.4 0 0.4 0.4 80 19 75 305 1 0 1 0 4.3 0.1 4.9 4.2 10/07/2004 12:20:00 2.8 1.1 5.3 0.4 3 1 4.9 0.4 0.4 0 0.4 0.4 95 20 113 305 0 0 0 0 4.6 0.1 5.2 4.4 10/07/2004 12:30:00 3.5 1 6.1 0.7 3.6 0.9 5.7 1.5 0.4 0 0.4 0.4 97 20 69 305 0 0 0 0 4.9 0.1 5.4 4.7 10/07/2004 12:40:00 4.2 1 6.8 1.9 4.3 0.8 6.8 2.6 0.4 0 0.4 0.4 90 13 98 305 0 0 0 0 5.1 0.2 5.6 4.9 10/07/2004 12:50:00 4.9 1 7.2 1.9 4.9 0.9 7.2 2.6 0.4 0 0.4 0.4 88 15 89 305 0 0 0 0 4.8 0 5.4 4.7 10/07/2004 13:00:00 5.1 0.8 7.2 2.6 5.2 0.8 6.8 3 0.4 0 0.4 0.4 112 12 106 305 0 0 0 0 4.9 0.1 5.4 4.4 10/07/2004 13:10:00 4.9 0.8 6.8 2.3 5.2 0.7 6.8 3.4 0.4 0 0.4 0.4 115 13 122 305 0 0 0 0 4.5 0.2 5.4 4.4 10/07/2004 13:20:00 5.4 1 7.6 2.6 5.5 0.9 7.2 3 0.4 0 0.4 0.4 121 8 124 305 0 0 0 0 4.4 0.1 4.9 4.4 10/07/2004 13:30:00 4.9 0.9 6.8 2.3 5.1 0.8 7.2 3 0.4 0 0.4 0.4 117 13 124 305 0 0 0 0 4.5 0 4.9 4.4 10/07/2004 13:40:00 5.2 0.7 6.8 3 5.3 0.6 7.2 3.8 0.4 0 0.4 0.4 107 13 103 305 0 0 0 0 4.7 0.1 5.2 4.4 10/07/2004 13:50:00 3.9 1 6.5 1.5 4.2 0.9 6.1 1.9 0.4 0 0.4 0.4 109 15 116 305 0 0 0 0 4.5 0.1 4.9 4.4 10/07/2004 14:00:00 4.2 1.3 8 1.1 4.4 1.2 8 2.3 0.4 0 0.4 0.4 112 17 127 305 0 0 0 0 4.5 0.1 4.9 4.4 10/07/2004 14:10:00 5 1.3 7.6 1.9 5.1 1.1 7.6 2.6 0.4 0 0.4 0.4 119 17 139 305 0 0 0 0 4.6 0 4.9 4.4 10/07/2004 14:20:00 5.3 1.1 8.4 3 5.3 1.1 8.4 2.6 0.4 0 0.4 0.4 121 13 125 305 0 0 0 0 4.7 0 4.9 4.7 10/07/2004 14:30:00 5.9 1.2 9.1 3.4 6 1.2 9.1 3.8 0.4 0 0.4 0.4 121 15 141 305 0 0 0 0 4.8 0 5.2 4.7 10/07/2004 14:40:00 6.2 1.1 9.1 3.4 6.2 1.1 9.1 3.4 0.4 0 0.4 0.4 123 13 121 305 0 0 0 0 4.8 0 5.4 4.9 10/07/2004 14:50:00 6.5 1 9.5 4.2 6.7 0.9 10.3 4.6 0.4 0 0.4 0.4 136 7 137 305 0 0 0 0 4.7 0.1 5.4 4.4 10/07/2004 15:00:00 5.5 0.9 7.2 2.3 5.7 0.8 7.6 3 0.4 0 0.4 0.4 137 9 144 305 1 0 1 0 4.4 0.1 4.9 4.4 10/07/2004 15:10:00 5.7 1 7.6 3.4 5.9 0.9 8 3.8 0.4 0 0.4 0.4 135 9 138 305 1 0 1 0 4.4 0 4.9 4.4 10/07/2004 15:20:00 7.5 0.8 9.5 4.9 7.5 0.8 9.1 4.6 0.4 0 0.4 0.4 137 5 137 305 1 0 1 0 4.4 0 4.9 4.4 10/07/2004 15:30:00 7.2 0.8 9.1 4.2 7.3 0.8 8.8 4.6 0.4 0 0.4 0.4 136 6 137 305 1 0 1 0 4.3 0 4.7 4.2 10/07/2004 15:40:00 7.1 0.8 9.1 4.6 7.2 0.8 9.1 4.9 0.4 0 0.4 0.4 135 7 129 305 1 0 1 0 4.2 0 4.7 4.2 10/07/2004 15:50:00 6.6 0.9 8.8 4.2 6.7 0.9 9.1 4.6 0.4 0 0.4 0.4 138 9 137 305 1 0 1 0 4.2 0 4.7 4.2 10/07/2004 16:00:00 5.4 1.2 9.5 2.6 5.5 1.1 9.5 2.6 0.4 0 0.4 0.4 126 17 139 305 2 0 1 0 4.1 0 4.7 4.2 10/07/2004 16:10:00 4.9 1.1 7.2 1.9 5 1 6.8 2.3 0.4 0 0.4 0.4 121 16 122 305 2 0 2 0 4.5 0.1 4.7 4.2 10/07/2004 16:20:00 5.6 1.2 8.8 1.9 5.6 1.2 8.8 2.6 0.4 0 0.4 0.4 126 13 114 305 1 0 1 0 4.4 0 4.9 4.4 10/07/2004 16:30:00 6.1 1.3 9.1 2.6 6 1.3 9.1 3.4 0.4 0 0.4 0.4 108 17 120 305 1 0 1 0 4.6 0 4.9 4.4 10/07/2004 16:40:00 6 1.2 9.5 3.4 6 1.1 9.1 3.4 0.4 0 0.4 0.4 102 13 114 305 1 0 1 0 4.6 0 5.2 4.4 10/07/2004 16:50:00 5.2 1.1 7.2 2.6 5.2 1.1 8.4 2.3 0.4 0 0.4 0.4 107 17 108 305 1 0 1 0 4.7 0.1 5.2 4.4 10/07/2004 17:00:00 5.1 1.5 10.3 1.1 5.1 1.4 9.5 1.9 0.4 0 0.4 0.4 112 17 123 305 1 0 1 0 4.8 0.1 5.2 4.7 10/07/2004 17:10:00 5.6 1.1 8.4 2.3 5.5 1 8.4 3 0.4 0 0.4 0.4 109 18 109 305 1 0 1 0 4.8 0.1 5.2 4.7 10/07/2004 17:20:00 4.8 1.2 7.2 1.1 4.9 1.1 8 1.5 0.4 0 0.4 0.4 109 22 108 305 1 0 1 0 4.7 0.1 5.2 4.4 10/07/2004 17:30:00 4.8 1.2 8 1.9 5.1 1.1 8.4 2.6 0.4 0 0.4 0.4 121 22 96 305 1 0 1 0 4.6 0.1 4.9 4.4 10/07/2004 17:40:00 5.5 1.4 8.8 2.3 5.6 1.2 8.8 3 0.4 0 0.4 0.4 129 17 136 305 1 0 1 0 4.5 0.1 4.9 4.2 10/07/2004 17:50:00 4.8 1.5 8.8 1.9 4.9 1.3 9.5 2.6 0.4 0 0.4 0.4 119 16 87 305 2 0 2 0 4.4 0.1 4.7 4.2 10/07/2004 18:00:00 4.1 1.2 7.2 1.1 4.4 1.1 8 1.5 0.4 0 0.4 0.4 119 21 124 305 2 0 2 0 4.3 0.1 4.7 4.2 10/07/2004 18:10:00 3.9 1.5 11.5 0.4 4.1 1.2 9.1 1.9 0.4 0 0.4 0.4 108 26 114 305 2 0 2 0 4.1 0 4.7 4.2 10/07/2004 18:20:00 5.2 1.4 8.8 1.9 5.4 1.4 9.1 1.9 0.4 0 0.4 0.4 115 19 125 305 2 0 2 0 4.1 0.1 4.7 3.9 10/07/2004 18:30:00 4.7 1.2 8.4 2.3 4.9 1.1 7.6 2.6 0.4 0 0.4 0.4 129 17 137 305 2 0 2 0 4.1 0.1 4.7 4.2 10/07/2004 18:40:00 4.8 1.7 9.9 0.4 5 1.6 9.9 1.1 0.4 0 0.4 0.4 126 18 109 305 2 0 2 0 4.2 0 4.7 4.2 10/07/2004 18:50:00 5.5 1.7 10.7 1.1 5.5 1.6 9.9 1.5 0.4 0 0.4 0.4 124 19 133 305 2 0 2 0 4.2 0 4.7 4.2 10/07/2004 19:00:00 4.7 1.3 8.4 1.1 4.8 1.3 8.8 1.9 0.4 0 0.4 0.4 121 22 125 305 2 0 2 0 4.2 0 4.7 4.2 10/07/2004 19:10:00 4.7 1.7 8.8 0.4 4.9 1.5 9.1 1.9 0.4 0 0.4 0.4 124 18 147 305 2 0 2 0 4.1 0 4.7 4.2 10/07/2004 19:20:00 5.3 1.7 8.8 1.9 5.5 1.6 9.1 2.3 0.4 0 0.4 0.4 128 17 142 305 2 0 2 0 4.1 0 4.7 4.2 10/07/2004 19:30:00 5.5 1.3 9.5 3 5.7 1.3 10.3 3.4 0.4 0 0.4 0.4 123 19 123 305 2 0 1 0 4 0 4.4 3.9 10/07/2004 19:40:00 4.9 1.5 9.5 0.7 5.1 1.4 9.5 1.9 0.4 0 0.4 0.4 109 20 122 305 2 0 2 0 4 0 4.4 3.9 10/07/2004 19:50:00 4.8 1.7 11.1 0.7 4.9 1.4 9.9 2.3 0.4 0 0.4 0.4 96 24 126 305 2 0 2 0 4 0 4.4 3.9 10/07/2004 20:00:00 3.3 1.5 7.2 0.4 3.6 1.1 6.8 0.4 0.4 0 0.4 0.4 87 26 98 305 2 0 2 0 4 0.2 4.4 3.9 10/07/2004 20:10:00 5.1 1.5 9.1 0.4 5 1.2 8 2.3 0.4 0 0.4 0.4 100 26 62 305 2 0 2 0 4 0.2 4.4 3.9 10/07/2004 20:20:00 5.2 1.4 9.5 1.9 5.2 1.3 8.8 2.3 0.4 0 0.4 0.4 105 21 83 305 2 0 2 0 4 0.2 4.4 3.9 10/07/2004 20:30:00 4.7 1.8 9.5 0.4 4.8 1.6 8.8 1.5 0.4 0 0.4 0.4 112 28 82 305 2 0 2 0 4 0.1 4.4 3.7 10/07/2004 20:40:00 4.9 1.6 8.8 0.4 4.7 1.5 9.1 1.5 0.4 0 0.4 0.4 108 21 128 305 2 0 1 0 4 0.2 4.4 3.7 10/07/2004 20:50:00 3.9 1.5 9.1 0.4 4.2 1.4 7.6 1.5 0.4 0 0.4 0.4 115 22 101 305 2 0 2 0 3.9 0.1 4.4 3.7 10/07/2004 21:00:00 5.3 1.4 8.8 1.9 5.3 1.3 8.8 2.3 0.4 0 0.4 0.4 135 17 133 305 1 0 1 0 3.9 0.1 4.4 3.7 10/07/2004 21:10:00 5.5 1.4 9.1 3 5.6 1.3 9.1 3 0.4 0 0.4 0.4 136 13 120 305 2 0 1 0 3.8 0.1 4.4 3.7 10/07/2004 21:20:00 6.9 1.2 9.9 3.8 6.9 1.2 10.3 3.8 0.4 0 0.4 0.4 129 12 129 305 2 0 1 0 3.6 0.1 4.2 3.4 10/07/2004 21:30:00 6 1.5 10.7 3 5.9 1.3 9.9 3.4 0.4 0 0.4 0.4 132 14 128 305 1 0 1 0 3.6 0.1 3.9 3.4 10/07/2004 21:40:00 5.9 1.7 9.9 2.6 6 1.5 9.9 2.6 0.4 0 0.4 0.4 129 18 135 305 1 0 1 0 3.6 0 4.2 3.4 10/07/2004 21:50:00 6.4 1.9 11.1 1.1 6.5 1.7 10.7 2.6 0.4 0 0.4 0.4 125 18 112 305 1 0 1 0 3.7 0 4.2 3.4 10/07/2004 22:00:00 6.8 1.5 10.3 2.6 6.8 1.3 10.3 3.4 0.4 0 0.4 0.4 126 17 134 305 2 0 1 0 3.7 0 4.2 3.4 10/07/2004 22:10:00 4.7 2.3 9.9 0.4 4.9 2 9.9 0.4 0.4 0 0.4 0.4 117 26 85 305 2 0 2 0 3.7 0 4.2 3.7 10/07/2004 22:20:00 3.4 1.2 7.2 0.4 3.5 1 6.5 0.7 0.4 0 0.4 0.4 92 27 64 305 2 0 2 0 3.7 0 4.2 3.4 10/07/2004 22:30:00 5.1 2.5 10.3 0.4 5.1 2.3 9.9 1.1 0.4 0 0.4 0.4 81 30 55 305 2 0 2 0 3.7 0 4.2 3.4 10/07/2004 22:40:00 4.9 1.2 8 1.5 4.8 1.1 7.6 1.9 0.4 0 0.4 0.4 102 30 114 305 3 0 2 0 3.6 0.1 4.2 3.4 10/07/2004 22:50:00 6.8 1.5 10.7 3 6.8 1.5 10.7 3.8 0.4 0 0.4 0.4 131 16 140 305 3 0 2 0 3.5 0.2 3.9 3.2 10/07/2004 23:00:00 6.3 1.5 11.1 3 6.1 1.4 10.3 2.3 0.4 0 0.4 0.4 128 15 142 305 3 0 2 0 3.4 0.2 3.9 3.2 10/07/2004 23:10:00 6.9 1.5 11.5 3.4 6.9 1.5 12.6 3 0.4 0 0.4 0.4 129 16 121 305 3 0 3 0 3.3 0.1 3.9 3.2 10/07/2004 23:20:00 6.3 1.5 9.9 2.3 6.2 1.5 10.3 1.9 0.4 0 0.4 0.4 129 20 130 305 3 0 4 0 3.3 0.1 3.7 3.2 10/07/2004 23:30:00 5.7 1.7 9.9 1.5 5.4 1.7 9.5 1.5 0.4 0 0.4 0.4 110 26 110 305 4 0 4 0 3.2 0 3.7 3.2 10/07/2004 23:40:00 6.7 2 11.8 3 6.6 1.9 11.8 1.9 0.4 0 0.4 0.4 107 22 121 305 4 0 4 0 3.2 0 3.7 3.2 10/07/2004 23:50:00 6 1.7 9.9 1.1 5.9 1.7 9.9 1.5 0.4 0 0.4 0.4 109 27 116 305 4 0 4 0 3.2 0 3.7 3.2 10/08/2004 00:00:00 5.3 1.7 9.9 0.4 5.3 1.7 9.9 1.1 0.4 0 0.4 0.4 100 20 117 305 4 0 4 0 3.3 0 3.7 2.9 10/08/2004 00:10:00 5.4 1.7 11.1 1.1 5.3 1.5 9.9 1.9 0.4 0 0.4 0.4 117 21 93 305 4 0 4 0 3.2 0 3.7 2.9 10/08/2004 00:20:00 5.3 1.5 9.1 1.5 5.2 1.3 9.9 2.6 0.4 0 0.4 0.4 112 22 84 305 4 0 5 0 3.2 0 3.7 2.9 10/08/2004 00:30:00 5.8 1.7 10.7 0.7 5.7 1.7 11.1 0.7 0.4 0 0.4 0.4 99 23 140 305 5 0 5 0 3.3 0.1 3.7 3.2 10/08/2004 00:40:00 4.9 1.9 9.9 0.4 4.9 1.7 9.5 0.7 0.4 0 0.4 0.4 93 26 101 305 5 0 5 0 3.3 0.1 3.7 3.2 10/08/2004 00:50:00 4.2 1.6 10.7 0.4 4.3 1.5 9.1 1.5 0.4 0 0.4 0.4 80 28 78 305 5 0 5 0 3.3 0.1 3.7 3.2 10/08/2004 01:00:00 7.3 2.3 13.7 3.4 7.2 2.2 14.9 3.4 0.4 0 0.4 0.4 73 21 60 305 5 0 5 0 3.5 0.2 4.2 3.2 10/08/2004 01:10:00 9 2.6 16.4 3.4 8.9 2.6 16.1 1.9 0.4 0 0.4 0.4 74 18 81 305 5 0 5 0 3.5 0.1 4.2 3.4 10/08/2004 01:20:00 10.4 2.4 16.8 4.9 10.3 2.6 16.4 4.6 0.4 0 0.4 0.4 72 21 53 305 4 0 4 0 3.5 0.1 4.2 3.4 10/08/2004 01:30:00 9.7 2.6 18.7 4.2 9.5 2.5 17.2 3.4 0.4 0 0.4 0.4 77 21 58 305 4 0 4 0 3.5 0.1 4.2 3.4 10/08/2004 01:40:00 9.3 2.5 16.8 4.2 9.3 2.4 16.8 4.2 0.4 0 0.4 0.4 70 21 51 305 4 0 4 0 3.5 0 4.2 3.4 10/08/2004 01:50:00 10.1 2.3 17.2 3.8 10.1 2.2 17.2 5.7 0.4 0 0.4 0.4 74 19 60 305 3 0 3 0 3.6 0 4.2 3.4 10/08/2004 02:00:00 10.9 2.7 19.9 4.2 10.8 2.8 17.9 5.7 0.4 0 0.4 0.4 76 21 83 305 3 0 3 0 3.6 0 4.2 3.4 10/08/2004 02:10:00 12.3 1.9 17.2 6.5 12.3 1.9 17.2 6.8 0.4 0 0.4 0.4 71 13 78 305 3 0 3 0 3.5 0 3.9 3.4 10/08/2004 02:20:00 12.9 1.8 17.6 8 12.7 1.9 20.2 6.8 0.4 0 0.4 0.4 73 9 61 305 4 0 4 0 3.6 0 4.2 3.4 10/08/2004 02:30:00 13.3 1.2 16.4 9.9 13 1.2 15.6 8 0.4 0 0.4 0.4 77 7 75 305 4 0 4 0 3.6 0 4.2 3.4 10/08/2004 02:40:00 13.7 1.1 16.8 10.3 13.4 1.2 17.2 9.9 0.4 0 0.4 0.4 77 5 66 305 4 0 4 0 3.6 0 4.2 3.4 10/08/2004 02:50:00 13.9 1.3 18.3 10.7 13.5 1.3 16.8 9.5 0.4 0 0.4 0.4 78 6 64 305 4 0 4 0 3.7 0.1 4.4 3.4 10/08/2004 03:00:00 12.7 1.5 16.1 9.5 12.3 1.5 15.6 8.8 0.4 0 0.4 0.4 77 6 78 305 5 0 5 0 3.4 0.2 4.2 3.2 10/08/2004 03:10:00 12.6 1.8 17.9 7.2 12.4 1.7 17.6 7.6 0.4 0 0.4 0.4 75 10 84 305 5 0 5 0 3.6 0.2 4.2 3.2 10/08/2004 03:20:00 13.7 1.7 19.5 9.5 13.3 1.7 19.5 8.4 0.4 0 0.4 0.4 77 9 67 305 4 0 4 0 3.9 0.2 4.4 3.7 10/08/2004 03:30:00 12.9 1.5 19.5 9.9 12.5 1.5 18.7 8.8 0.4 0 0.4 0.4 79 8 74 305 4 0 4 0 3.8 0.1 4.4 3.7 10/08/2004 03:40:00 12.9 1.3 15.6 7.2 12.2 1.3 15.3 8.4 0.4 0 0.4 0.4 75 6 87 305 4 0 4 0 3.9 0.1 4.4 3.7 10/08/2004 03:50:00 12.5 1.2 16.1 8.8 12 1.2 16.1 8.4 0.4 0 0.4 0.4 75 6 64 305 5 0 5 0 3.7 0 4.2 3.4 10/08/2004 04:00:00 13.1 1.3 17.2 8.8 12.7 1.3 18.3 8.8 0.4 0 0.4 0.4 78 8 80 305 5 0 5 0 3.9 0.2 4.4 3.7 10/08/2004 04:10:00 13.1 1.3 16.8 9.5 12.7 1.4 16.4 7.6 0.4 0 0.4 0.4 79 7 77 305 4 0 4 0 3.9 0.2 4.4 3.7 10/08/2004 04:20:00 12.9 1.5 16.8 8 12.4 1.5 16.4 8 0.4 0 0.4 0.4 79 9 61 305 4 0 4 0 3.9 0.2 4.4 3.7 10/08/2004 04:30:00 13.4 1 16.4 10.3 12.8 1.1 16.8 9.9 0.4 0 0.4 0.4 79 7 92 305 4 0 4 0 3.9 0.2 4.4 3.7 10/08/2004 04:40:00 13.4 1.1 16.4 10.7 12.9 1.2 16.4 9.5 0.4 0 0.4 0.4 78 6 80 305 4 0 4 0 3.9 0.2 4.4 3.7 10/08/2004 04:50:00 13.2 1.2 16.1 10.3 12.7 1.3 15.6 9.1 0.4 0 0.4 0.4 76 5 80 305 4 0 4 0 4 0.2 4.4 3.7 10/08/2004 05:00:00 14 1.1 16.8 10.3 13.5 1.2 16.8 9.9 0.4 0 0.4 0.4 77 6 78 305 4 0 4 0 3.9 0.2 4.4 3.7 10/08/2004 05:10:00 13 1.4 16.8 9.5 12.4 1.4 15.6 8 0.4 0 0.4 0.4 77 7 79 305 4 0 4 0 4 0.2 4.4 3.7 10/08/2004 05:20:00 14.5 1.3 19.1 10.7 13.9 1.3 17.6 9.9 0.4 0 0.4 0.4 77 6 76 305 3 0 3 0 4 0.2 4.4 3.7 10/08/2004 05:30:00 13.7 1.4 16.8 10.3 13.1 1.4 16.1 9.9 0.4 0 0.4 0.4 79 6 74 305 3 0 3 0 3.8 0.1 4.4 3.7 10/08/2004 05:40:00 14.1 1.4 20.2 9.5 13.4 1.4 18.7 9.1 0.4 0 0.4 0.4 77 6 77 305 3 0 4 0 3.8 0.1 4.4 3.7 10/08/2004 05:50:00 13.9 1.3 17.2 10.3 13.3 1.3 16.4 8.4 0.4 0 0.4 0.4 78 6 74 305 4 0 4 0 3.8 0 4.4 3.7 10/08/2004 06:00:00 14.4 1.5 17.9 9.9 13.9 1.4 17.2 9.5 0.4 0 0.4 0.4 78 6 74 305 3 0 4 0 3.9 0.2 4.4 3.7 10/08/2004 06:10:00 13.5 1.3 17.6 10.3 13 1.3 16.8 9.5 0.4 0 0.4 0.4 78 7 85 305 3 0 3 0 3.9 0.2 4.4 3.7 10/08/2004 06:20:00 13.2 1.5 17.6 9.9 12.5 1.5 16.4 9.9 0.4 0 0.4 0.4 76 7 80 305 3 0 3 0 3.9 0.2 4.4 3.7 10/08/2004 06:30:00 12.3 1.3 16.8 8.8 11.7 1.2 15.3 8.8 0.4 0 0.4 0.4 76 7 76 305 4 0 4 0 3.8 0 4.4 3.4 10/08/2004 06:40:00 13.8 1.5 18.3 8.8 13.2 1.5 17.2 8.8 0.4 0 0.4 0.4 74 6 80 305 4 0 4 0 3.8 0.2 4.4 3.7 10/08/2004 06:50:00 14.2 1.3 17.2 9.5 13.6 1.3 16.4 8.8 0.4 0 0.4 0.4 77 7 68 305 4 0 4 0 3.8 0.1 4.4 3.7 10/08/2004 07:00:00 14.2 1.2 17.6 10.7 13.6 1.2 17.2 10.7 0.4 0 0.4 0.4 77 5 75 305 4 0 4 0 3.8 0.1 4.4 3.7 10/08/2004 07:10:00 13.4 1.4 17.2 9.5 12.9 1.4 16.1 9.1 0.4 0 0.4 0.4 75 7 82 305 4 0 4 0 3.9 0.1 4.4 3.7 10/08/2004 07:20:00 12.7 1.7 17.6 7.6 12.2 1.7 17.2 7.6 0.4 0 0.4 0.4 76 9 72 305 4 0 4 0 3.9 0.2 4.4 3.7 10/08/2004 07:30:00 14.2 1.7 19.1 9.1 13.7 1.7 18.7 7.6 0.4 0 0.4 0.4 77 8 74 305 5 0 5 0 3.9 0.1 4.4 3.7 10/08/2004 07:40:00 14.2 1.7 19.1 9.5 13.8 1.7 18.3 9.5 0.4 0 0.4 0.4 78 7 80 305 4 0 4 0 3.9 0.2 4.4 3.7 10/08/2004 07:50:00 14.3 1.7 18.7 9.1 13.8 1.8 18.3 8.4 0.4 0 0.4 0.4 76 7 75 305 5 0 5 0 3.9 0.1 4.4 3.7 10/08/2004 08:00:00 13.6 2 18.7 7.2 13.3 1.9 18.7 8 0.4 0 0.4 0.4 74 9 76 305 5 0 5 0 3.8 0 4.4 3.7 10/08/2004 08:10:00 14.1 1.5 18.3 8 13.6 1.7 17.2 7.6 0.4 0 0.4 0.4 76 8 71 305 5 0 6 0 3.8 0 4.4 3.7 10/08/2004 08:20:00 14 1.5 17.6 8.8 13.5 1.5 17.6 9.5 0.4 0 0.4 0.4 77 7 85 305 5 0 6 0 3.8 0.1 4.4 3.7 10/08/2004 08:30:00 13 1.7 17.9 8.8 12.5 1.7 17.9 8 0.4 0 0.4 0.4 75 7 72 305 6 0 6 0 3.9 0.1 4.4 3.7 10/08/2004 08:40:00 13.4 1.5 18.7 9.9 12.9 1.5 17.6 8.8 0.4 0 0.4 0.4 75 7 77 305 6 0 6 0 3.9 0.2 4.4 3.7 10/08/2004 08:50:00 13.1 1.7 17.2 8.4 12.7 1.7 17.6 6.8 0.4 0 0.4 0.4 74 10 71 305 7 0 7 0 4 0.2 4.7 3.7 10/08/2004 09:00:00 13.2 1.7 17.9 8.4 12.8 1.8 17.9 8 0.4 0 0.4 0.4 74 10 72 305 7 0 7 0 4.1 0.1 4.7 3.9 10/08/2004 09:10:00 13.9 1.8 18.3 9.5 13.5 2 19.1 8.4 0.4 0 0.4 0.4 73 8 63 305 7 0 7 0 4.1 0.2 4.7 3.9 10/08/2004 09:20:00 13.6 1.8 19.9 7.6 13.4 1.9 18.7 8 0.4 0 0.4 0.4 74 10 84 305 7 0 7 0 4.2 0.1 4.7 4.2 10/08/2004 09:30:00 14 1.5 18.7 8.4 13.7 1.7 17.6 9.5 0.4 0 0.4 0.4 76 8 89 305 7 0 7 0 4.2 0 4.7 4.2 10/08/2004 09:40:00 13.2 1.7 17.9 8.8 12.7 1.7 16.8 8.4 0.4 0 0.4 0.4 75 6 80 305 7 0 7 0 4.2 0.2 4.7 4.2 10/08/2004 09:50:00 13.2 1.5 17.2 8.8 12.6 1.5 16.4 8.4 0.4 0 0.4 0.4 77 7 93 305 7 0 7 0 4.1 0.1 4.7 3.9 10/08/2004 10:00:00 13.8 1.7 19.5 7.2 13.4 1.8 20.2 9.1 0.4 0 0.4 0.4 73 9 66 305 7 0 7 0 4.1 0 4.7 3.9 10/08/2004 10:10:00 13.3 2.3 19.9 6.1 13.3 2.5 21.4 4.9 0.4 0 0.4 0.4 71 13 71 305 7 0 7 0 4.4 0.1 4.9 4.2 10/08/2004 10:20:00 13.4 2.1 19.1 8.4 13.3 2.2 18.7 8 0.4 0 0.4 0.4 70 11 63 305 7 0 7 0 4.5 0.1 5.2 4.4 10/08/2004 10:30:00 14 1.9 19.9 9.1 14 2.2 21.4 8.8 0.4 0 0.4 0.4 68 10 76 305 7 0 7 0 4.8 0.1 5.4 4.4 10/08/2004 10:40:00 14.4 2.1 19.9 9.1 14 2.2 20.6 8.8 0.4 0 0.4 0.4 71 10 70 305 7 0 7 0 4.9 0.1 5.4 4.7 10/08/2004 10:50:00 14.9 2.1 19.9 6.5 14.7 2.3 20.6 7.6 0.4 0 0.4 0.4 72 10 67 305 6 0 6 0 4.9 0.1 5.4 4.9 10/08/2004 11:00:00 15.3 1.7 19.1 10.3 15 1.8 19.9 9.9 0.4 0 0.4 0.4 73 8 81 305 6 0 6 0 4.9 0.1 5.4 4.9 10/08/2004 11:10:00 14.9 1.8 20.6 8 14.7 1.8 20.6 9.9 0.4 0 0.4 0.4 73 9 68 305 6 0 6 0 5 0.2 5.4 4.9 10/08/2004 11:20:00 15 1.7 19.9 11.1 14.7 1.8 19.1 9.9 0.4 0 0.4 0.4 73 9 62 305 6 0 6 0 5 0.2 5.4 4.9 10/08/2004 11:30:00 15.1 1.8 19.1 8.8 14.8 1.9 19.1 8.8 0.4 0 0.4 0.4 73 8 70 305 7 0 7 0 5.1 0.1 5.6 4.9 10/08/2004 11:40:00 15.1 1.5 20.6 11.1 14.7 1.6 20.2 10.3 0.4 0 0.4 0.4 75 7 78 305 7 0 7 0 5.2 0.1 5.6 4.9 10/08/2004 11:50:00 15.6 1.4 22.6 12.2 15.2 1.5 20.2 10.3 0.6 1.8 17.6 0.4 75 6 78 305 7 0 7 0 5.1 0.2 5.6 4.9 10/08/2004 12:00:00 15.6 1.5 20.6 10.3 15.2 1.5 19.1 11.8 0.4 0 0.4 0.4 76 8 72 305 7 0 7 0 5 0.2 5.6 4.9 10/08/2004 12:10:00 15.2 2 21 9.9 15.1 2.1 20.6 9.5 0.4 0 0.4 0.4 73 9 81 305 7 1 7 0 5 0.2 5.6 4.9 10/08/2004 12:20:00 14.8 2 23.3 9.1 14.7 2.1 22.6 8.8 0.4 0 0.4 0.4 73 9 81 305 11 0 11 0 5 0.2 5.6 4.9 10/08/2004 12:30:00 15.1 1.9 19.5 9.5 15.1 2.1 19.9 10.3 0.4 0 0.4 0.4 72 11 64 305 12 0 12 0 5.1 0.1 5.6 4.9 10/08/2004 12:40:00 14.7 2 21 9.5 14.6 2.3 21 6.5 0.4 0 0.4 0.4 73 9 64 305 12 0 12 0 5.2 0.1 5.6 4.9 10/08/2004 12:50:00 14.9 2.2 22.1 9.5 14.7 2.3 21.4 9.9 0.4 0 0.4 0.4 71 10 82 305 13 0 13 0 5.2 0.1 5.6 4.9 10/08/2004 13:00:00 14.6 2.2 21 8.8 14.4 2.4 21.8 8.4 0.4 0 0.4 0.4 71 10 67 305 13 0 13 0 5.2 0.1 5.6 5.2 10/08/2004 13:10:00 15.3 2 20.2 9.5 15.1 2.1 20.2 9.1 0.4 0 0.4 0.4 72 9 80 305 13 0 13 0 5.2 0.1 5.6 5.2 10/08/2004 13:20:00 14.4 1.8 22.1 9.5 14 2.1 21.4 8.4 0.4 0 0.4 0.4 73 9 77 305 14 0 14 0 5.2 0.1 5.6 4.9 10/08/2004 13:30:00 14.9 1.7 19.9 10.7 14.7 1.9 21 9.5 0.4 0 0.4 0.4 73 8 59 305 14 0 14 0 5.2 0 5.6 4.9 10/08/2004 13:40:00 15.3 1.7 19.1 10.3 15 1.8 19.9 10.3 0.4 0 0.4 0.4 73 7 78 305 14 0 14 0 5.3 0.1 5.6 5.2 10/08/2004 13:50:00 15 1.5 20.6 11.1 14.8 1.6 21.4 11.1 0.4 0 0.4 0.4 75 8 87 305 14 0 14 0 5.2 0 5.6 5.2 10/08/2004 14:00:00 14.7 1.8 19.1 9.5 14.4 1.8 19.9 9.9 0.4 0 0.4 0.4 75 8 71 305 14 0 14 0 5.2 0.1 5.6 5.2 10/08/2004 14:10:00 15.7 1.9 20.2 10.3 15.3 1.9 19.9 8.8 0.4 0 0.4 0.4 74 7 77 305 15 0 15 0 5.2 0 5.6 5.2 10/08/2004 14:20:00 14.8 1.5 18.7 11.1 14.6 1.7 19.9 10.7 0.4 0 0.4 0.4 74 7 80 305 15 0 15 0 5.2 0.1 5.6 5.2 10/08/2004 14:30:00 14.5 1.4 18.3 11.5 14.2 1.4 18.3 11.1 0.4 0 0.4 0.4 73 7 61 305 15 0 15 0 5.1 0.1 5.6 4.9 10/08/2004 14:40:00 14.6 1.4 18.7 11.1 14.4 1.5 19.9 11.1 0.4 0 0.4 0.4 73 7 77 305 15 0 15 0 5.1 0.1 5.6 4.9 10/08/2004 14:50:00 14.5 1.5 18.7 11.5 14.2 1.6 18.7 11.1 0.4 0 0.4 0.4 73 8 77 305 15 0 15 0 5.1 0.1 5.6 4.9 10/08/2004 15:00:00 14.7 1.5 18.7 11.1 14.2 1.6 19.9 9.5 0.4 0 0.4 0.4 73 7 75 305 15 0 15 0 5.1 0.1 5.6 4.9 10/08/2004 15:10:00 14.9 1.5 21.8 11.8 14.6 1.7 21 10.3 0.4 0 0.4 0.4 73 8 81 305 15 0 15 0 5 0.1 5.6 4.9 10/08/2004 15:20:00 15.2 1.5 19.1 10.7 14.9 1.5 18.7 9.9 0.4 0 0.4 0.4 71 6 73 305 15 0 15 0 5 0.2 5.6 4.9 10/08/2004 15:30:00 15.3 1.4 19.1 11.1 15 1.5 19.1 9.9 2.8 5.4 18.3 0.4 74 6 75 305 29 36 15 0 5 0.1 5.6 4.9 10/08/2004 15:40:00 15.7 1.5 19.5 11.5 15.3 1.7 19.9 10.3 15.1 1.5 19.1 10.3 75 7 81 305 93 10 90 0 5 0.2 5.6 4.9 10/08/2004 15:50:00 15.1 1.4 19.1 11.8 14.7 1.5 18.3 11.5 8.5 6.7 17.6 0.4 77 7 82 305 133 21 92 0 5 0.2 5.6 4.9 10/08/2004 16:00:00 14.7 1.4 18.7 11.5 14.4 1.5 19.1 9.9 0.4 0 0.4 0.4 76 7 72 305 144 3 143 0 5 0.2 5.6 4.9 10/08/2004 16:10:00 14.9 1.3 18.7 11.5 14.7 1.5 18.7 11.5 0.4 0 0.4 0.4 74 6 71 305 142 2 141 0 5 0.2 5.6 4.9 10/08/2004 16:20:00 15 1.2 21 12.2 14.6 1.3 18.3 11.1 0.4 0 0.4 0.4 73 6 67 305 91 13 88 0 5 0.2 5.6 4.9 10/08/2004 16:30:00 15 1.4 19.9 11.8 14.7 1.5 19.9 11.1 0.4 0 0.4 0.4 72 7 69 305 88 0 88 0 5 0.2 5.6 4.9 10/08/2004 16:40:00 15.5 1.5 20.2 11.8 15.1 1.6 19.5 11.5 0.4 0 0.4 0.4 72 6 70 305 88 0 88 0 5 0.2 5.6 4.9 10/08/2004 16:50:00 16.2 1.4 20.2 13 15.9 1.5 19.9 12.2 0.4 0 0.4 0.4 71 6 71 305 88 0 88 0 5 0.1 5.4 4.9 10/08/2004 17:00:00 16.2 1.2 19.9 11.8 16 1.3 19.5 12.6 0.4 0 0.4 0.4 70 6 76 305 89 0 88 0 4.8 0 5.2 4.9 10/08/2004 17:10:00 16.3 1.2 20.2 13.7 16.1 1.5 20.6 12.6 0.4 0 0.4 0.4 71 6 78 305 89 0 90 0 4.8 0 5.4 4.7 10/08/2004 17:20:00 16.5 1.2 20.2 13.3 16.3 1.4 21 13 0.4 0 0.4 0.4 70 6 67 305 89 0 90 0 4.8 0 5.2 4.7 10/08/2004 17:30:00 16.5 1.3 19.9 13 16.2 1.5 19.9 12.2 0.4 0 0.7 0.4 70 6 76 305 90 0 90 0 4.8 0 5.2 4.7 10/08/2004 17:40:00 16.4 1.2 19.5 12.6 16.3 1.3 20.2 12.6 0.4 0 0.4 0.4 69 5 63 305 90 0 90 0 4.7 0 5.2 4.7 10/08/2004 17:50:00 16.2 1 18.7 13.3 16.1 1.1 19.1 12.2 0.4 0 0.4 0.4 69 5 68 305 90 0 90 0 4.7 0 5.2 4.7 10/08/2004 18:00:00 16.3 1.2 19.5 12.6 16.2 1.2 19.1 13 0.4 0 0.4 0.4 69 5 66 305 90 0 90 0 4.8 0 5.2 4.7 10/08/2004 18:10:00 16.3 1.2 19.5 12.6 16.2 1.3 19.5 12.6 0.4 0 0.4 0.4 69 5 79 305 91 0 91 0 4.7 0 5.2 4.7 10/08/2004 18:20:00 15.9 1.1 20.6 13.3 15.8 1.2 20.6 13 0.4 0 0.4 0.4 70 6 71 305 91 0 91 0 4.6 0 4.9 4.4 10/08/2004 18:30:00 16.1 1.1 19.5 13.3 16 1.3 19.1 11.8 0.4 0 0.4 0.4 69 5 77 305 91 0 91 0 4.6 0 4.9 4.4 10/08/2004 18:40:00 16.1 0.9 18.3 13 16 1 18.3 13.3 0.4 0 0.4 0.4 67 4 64 305 91 0 91 0 4.6 0.1 5.2 4.4 10/08/2004 18:50:00 16 1 19.9 13.7 15.7 1.1 19.1 13 0.4 0 0.4 0.4 68 4 75 305 92 0 92 0 4.5 0.1 4.9 4.4 10/08/2004 19:00:00 15.9 1.1 19.5 13.3 15.8 1.2 20.2 13 0.4 0 0.4 0.4 70 5 64 305 92 0 92 0 4.5 0.1 4.9 4.4 10/08/2004 19:10:00 17.3 1.3 20.2 13.7 17.1 1.3 20.2 13.7 0.4 0 0.4 0.4 70 4 67 305 92 0 92 0 4.4 0.1 4.9 4.2 10/08/2004 19:20:00 15.1 1.2 18.3 11.5 15 1.3 18.3 11.5 0.4 0 0.4 0.4 71 5 69 305 92 0 92 0 4.4 0.1 4.9 4.4 10/08/2004 19:30:00 16.2 1.1 19.5 12.6 16.1 1.3 19.1 11.8 0.4 0 0.4 0.4 69 5 70 305 93 0 93 0 4.4 0 4.9 4.2 10/08/2004 19:40:00 15.4 1.1 18.3 11.1 15.3 1.3 18.7 11.5 0.4 0 0.4 0.4 70 5 72 305 94 0 94 0 4.4 0.1 4.9 4.2 10/08/2004 19:50:00 16.8 1.1 19.5 13.7 16.5 1.2 19.5 13 0.4 0 0.4 0.4 69 4 75 305 95 0 95 0 4.3 0 4.7 4.2 10/08/2004 20:00:00 17.5 1 20.6 14.9 17.4 1.1 20.2 14.1 0.4 0 0.4 0.4 69 3 70 305 95 0 95 0 4.1 0 4.7 3.9 10/08/2004 20:10:00 16.8 1.1 20.2 13.7 16.7 1.2 19.9 13.3 0.4 0 0.4 0.4 70 5 71 305 95 0 95 0 4 0 4.7 4.2 10/08/2004 20:20:00 16.2 1.2 19.1 12.2 15.8 1.3 18.3 11.5 0.4 0 0.4 0.4 72 5 74 305 95 0 95 0 4.2 0 4.7 4.2 10/08/2004 20:30:00 15.3 1.1 19.1 12.2 15.3 1.2 19.1 11.8 0.4 0 0.4 0.4 71 5 75 305 95 0 95 0 4.3 0 4.7 4.2 10/08/2004 20:40:00 15.2 1.1 19.1 11.8 15 1.2 17.9 11.8 0.4 0 0.4 0.4 72 5 80 305 95 0 96 0 4.1 0 4.7 4.2 10/08/2004 20:50:00 14 1.2 17.6 11.1 13.7 1.3 17.9 10.7 0.4 0 0.4 0.4 76 6 80 305 95 0 95 0 4.2 0.1 4.7 3.9 10/08/2004 21:00:00 13.3 1.1 16.8 9.5 12.8 1.2 15.6 9.5 0.4 0 0.4 0.4 77 6 79 305 96 0 95 0 4.1 0 4.7 3.9 10/08/2004 21:10:00 12.5 1.3 15.6 9.5 12.1 1.3 15.6 9.1 0.4 0 0.4 0.4 78 6 74 305 96 0 96 0 4.1 0.1 4.7 4.2 10/08/2004 21:20:00 13.2 0.9 15.3 10.3 12.9 1 14.9 9.5 0.4 0 0.4 0.4 70 5 68 305 96 0 95 0 4.4 0.2 4.9 4.2 10/08/2004 21:30:00 13.7 0.8 15.6 11.5 13.5 0.8 16.4 11.5 0.4 0 0.4 0.4 67 4 71 305 96 0 96 0 4.6 0.1 5.2 4.4 10/08/2004 21:40:00 13.4 0.9 15.6 10.7 13.1 1 16.1 10.3 0.4 0 0.4 0.4 65 4 69 305 97 0 97 0 4.6 0.1 5.2 4.4 10/08/2004 21:50:00 12 1.5 15.3 8.4 11.7 1.7 15.3 8.4 0.4 0 0.4 0.4 63 4 68 305 97 0 97 0 4.7 0.1 5.2 4.4 10/08/2004 22:00:00 10.9 0.9 13 8.8 10.6 1 13.3 8.4 0.4 0 0.4 0.4 59 3 58 305 97 0 97 0 4.5 0.1 4.9 4.4 10/08/2004 22:10:00 12 0.8 14.1 9.1 11.8 0.9 14.1 8.4 0.4 0 0.4 0.4 59 3 63 305 98 0 97 0 4.5 0.1 4.9 4.4 10/08/2004 22:20:00 12.8 1 14.9 10.3 12.3 1.1 14.9 9.5 0.4 0 0.4 0.4 61 5 61 305 98 0 97 0 4.5 0.1 4.9 4.4 10/08/2004 22:30:00 12.2 1.1 14.5 9.5 11.9 1.2 14.5 9.1 0.4 0 0.4 0.4 60 5 66 305 98 0 97 0 4.5 0.1 4.9 4.4 10/08/2004 22:40:00 12.3 1.2 15.6 9.9 12 1.2 15.3 9.5 0.4 0 0.4 0.4 60 4 56 305 98 0 97 0 4.4 0.1 4.9 4.4 10/08/2004 22:50:00 13.2 1.2 16.1 10.7 12.9 1.3 16.1 9.1 0.4 0 0.4 0.4 58 5 50 305 98 0 97 0 4.5 0.1 4.9 4.4 10/08/2004 23:00:00 13.1 1.2 16.4 9.9 12.7 1.3 16.4 9.5 0.4 0 0.4 0.4 57 4 58 305 98 0 97 0 4.5 0.1 5.2 4.4 10/08/2004 23:10:00 13 0.9 14.9 10.3 12.7 1 14.9 9.9 0.4 0 0.4 0.4 57 4 43 305 98 0 97 0 4.6 0.1 5.2 4.4 10/08/2004 23:20:00 12.6 0.9 14.5 9.5 12.2 1 14.5 9.5 0.4 0 0.4 0.4 57 4 63 305 98 0 98 0 4.6 0.1 5.2 4.4 10/08/2004 23:30:00 13 0.9 15.3 10.7 12.7 1 15.3 10.3 0.4 0 0.4 0.4 54 3 50 305 98 0 97 0 4.6 0 5.2 4.4 10/08/2004 23:40:00 12.9 1 15.3 10.3 12.5 1.1 14.9 9.5 0.4 0 0.4 0.4 53 4 46 305 98 0 97 0 4.6 0.1 5.2 4.4 10/08/2004 23:50:00 12.7 0.9 14.9 9.9 12.4 1.1 15.3 9.5 0.4 0 0.4 0.4 46 4 45 305 98 0 97 0 4.4 0.1 4.9 4.2 10/09/2004 00:00:00 12.9 0.8 14.9 9.5 12.7 0.8 14.5 10.7 0.4 0 0.4 0.4 46 4 48 305 98 0 97 0 4.4 0.1 4.9 4.2 10/09/2004 00:10:00 13.6 1.1 16.8 11.5 13.3 1.2 16.8 10.7 0.4 0 0.4 0.4 46 4 50 305 98 0 97 0 4.4 0 4.7 4.2 10/09/2004 00:20:00 14.2 1 16.4 11.8 13.9 1.1 16.4 11.1 0.4 0 0.4 0.4 48 4 46 305 98 0 97 0 4.2 0.1 4.7 4.2 10/09/2004 00:30:00 14.2 0.8 16.1 12.2 14 0.9 16.1 11.5 0.4 0 0.4 0.4 47 4 42 305 98 0 98 0 4.2 0.1 4.7 4.2 10/09/2004 00:40:00 14.8 1.3 17.2 11.1 14.6 1.4 17.6 10.7 0.4 0 0.4 0.4 46 4 42 305 98 0 98 0 4.2 0.1 4.7 4.2 10/09/2004 00:50:00 15 1 17.2 11.8 14.8 1.1 17.6 11.8 0.4 0 0.4 0.4 47 4 50 305 90 5 98 0 4.1 0.1 4.7 4.2 10/09/2004 01:00:00 13.5 1.2 16.4 9.9 13.3 1.3 16.8 9.9 0.4 0 0.4 0.4 48 4 48 305 83 0 83 0 4.1 0.1 4.7 3.9 10/09/2004 01:10:00 14.1 1 16.4 11.5 13.9 1.1 16.4 11.1 0.4 0 0.4 0.4 48 4 44 305 82 0 82 0 4.2 0 4.7 4.2 10/09/2004 01:20:00 13.6 1.2 16.4 10.3 13.4 1.3 17.2 9.9 0.4 0 0.4 0.4 47 5 45 305 83 2 82 0 4.2 0.2 4.7 4.2 10/09/2004 01:30:00 14.5 1.1 16.8 11.8 14.5 1.2 17.6 10.7 0.4 0 0.4 0.4 44 4 49 305 85 0 85 0 4 0.2 4.7 3.9 10/09/2004 01:40:00 14.2 1.1 16.4 11.1 14.1 1.2 17.2 10.3 0.4 0 0.4 0.4 47 4 53 305 84 0 84 0 4 0.2 4.4 3.7 10/09/2004 01:50:00 14.2 1 16.8 11.5 14 1.1 16.8 10.7 0.4 0 0.4 0.4 50 5 52 305 84 0 85 0 4 0.2 4.4 3.9 10/09/2004 02:00:00 14.8 1.3 17.9 11.5 14.6 1.5 17.9 10.7 0.4 0 0.4 0.4 50 4 50 305 84 0 84 0 4 0.1 4.4 3.7 10/09/2004 02:10:00 14.3 1.4 17.9 11.1 14.2 1.6 17.9 10.7 0.4 0 0.4 0.4 49 5 45 305 84 0 84 0 4 0.2 4.4 3.7 10/09/2004 02:20:00 14.4 1.1 17.2 11.8 14.2 1.3 17.9 11.1 0.4 0 0.4 0.4 48 4 52 305 84 0 84 0 4 0.2 4.7 3.9 10/09/2004 02:30:00 14.6 1.2 17.6 11.8 14.5 1.3 17.2 11.5 0.4 0 0.4 0.4 46 4 43 305 83 0 84 0 4.1 0.1 4.7 3.9 10/09/2004 02:40:00 14.7 1 17.2 11.1 14.6 1.1 17.2 11.5 0.4 0 0.4 0.4 47 4 50 305 83 0 83 0 4.2 0.1 4.7 3.9 10/09/2004 02:50:00 14.3 1.2 16.8 11.1 14.1 1.5 16.8 10.7 0.4 0 0.4 0.4 46 4 46 305 83 0 83 0 4.2 0 4.7 4.2 10/09/2004 03:00:00 13.8 1.1 16.8 11.1 13.5 1.3 16.4 9.9 0.4 0 0.4 0.4 46 4 43 305 83 0 82 0 4.1 0.1 4.7 4.2 10/09/2004 03:10:00 13.9 1 17.2 11.5 13.9 1.2 16.8 11.1 0.4 0 0.4 0.4 44 4 44 305 85 2 87 0 4 0.1 4.7 3.9 10/09/2004 03:20:00 14.1 1 16.4 11.1 14 1.1 16.1 10.3 0.4 0 0.4 0.4 46 4 48 305 86 0 86 0 4 0 4.4 3.9 10/09/2004 03:30:00 14.5 1.1 17.6 11.8 14.2 1.3 17.9 11.1 0.4 0 0.4 0.4 46 4 48 305 85 0 85 0 4 0 4.7 3.9 10/09/2004 03:40:00 14.4 1.1 17.2 11.8 14.3 1.2 16.8 11.5 0.4 0 0.4 0.4 44 3 46 305 84 0 84 0 3.9 0.1 4.4 3.7 10/09/2004 03:50:00 13.3 0.9 15.3 10.3 13 1.1 15.6 10.7 0.4 0 0.4 0.4 44 4 39 305 84 0 84 0 3.9 0 4.4 3.7 10/09/2004 04:00:00 14 0.9 15.6 11.8 13.8 1 16.1 10.7 0.4 0 0.4 0.4 41 4 37 305 84 0 84 0 3.9 0.2 4.4 3.7 10/09/2004 04:10:00 13.2 1.1 15.3 9.5 13.1 1.3 15.6 8.4 0.4 0 0.4 0.4 44 4 40 305 84 0 84 0 4 0.2 4.4 3.7 10/09/2004 04:20:00 13.8 1 15.6 11.1 13.7 1 16.1 10.7 0.4 0 0.4 0.4 45 4 46 305 84 0 84 0 4 0.2 4.7 3.9 10/09/2004 04:30:00 13.9 0.9 16.1 11.5 13.7 1.1 16.4 10.7 0.4 0 0.4 0.4 45 4 48 305 84 0 84 0 4.1 0.1 4.7 3.9 10/09/2004 04:40:00 14 1 16.4 11.8 13.9 1.1 16.4 11.1 0.4 0 0.4 0.4 43 4 36 305 83 0 84 0 4 0.2 4.7 3.7 10/09/2004 04:50:00 13 1 15.6 9.9 12.8 1.2 15.6 9.9 0.4 0 0.4 0.4 42 5 41 305 84 0 84 0 3.9 0.1 4.4 3.7 10/09/2004 05:00:00 14 1.1 16.4 10.7 13.8 1.2 16.1 10.3 0.4 0 0.4 0.4 44 4 41 305 83 0 84 0 3.9 0.2 4.4 3.7 10/09/2004 05:10:00 13.8 0.8 15.6 11.1 13.6 1 16.1 10.7 0.4 0 0.4 0.4 45 4 44 305 83 0 83 0 3.9 0.1 4.4 3.7 10/09/2004 05:20:00 13.5 1 16.1 10.7 13.4 1.1 16.4 9.9 0.4 0 0.4 0.4 44 4 46 305 83 0 83 0 3.9 0.1 4.4 3.7 10/09/2004 05:30:00 13.9 1.1 17.2 11.1 13.8 1.2 17.2 10.7 0.4 0 0.4 0.4 45 4 45 305 83 0 84 0 3.9 0.2 4.4 3.7 10/09/2004 05:40:00 13.8 1.1 16.4 10.7 13.6 1.2 16.4 10.7 0.4 0 0.4 0.4 44 4 46 305 83 0 83 0 3.9 0.1 4.4 3.7 10/09/2004 05:50:00 13.8 1.1 16.1 9.5 13.8 1.2 16.1 10.3 0.4 0 0.4 0.4 43 4 44 305 83 0 83 0 3.9 0.2 4.4 3.7 10/09/2004 06:00:00 13.5 1 16.4 11.1 13.3 1.1 16.8 9.5 0.4 0 0.4 0.4 42 5 38 305 83 0 83 0 3.9 0.2 4.4 3.7 10/09/2004 06:10:00 13.8 1.1 16.8 11.1 13.5 1.1 17.2 10.7 0.4 0 0.4 0.4 43 4 48 305 83 0 83 0 4 0.2 4.4 3.7 10/09/2004 06:20:00 13.8 1.3 16.8 10.3 13.5 1.4 16.8 10.3 0.4 0 0.4 0.4 43 4 41 305 83 0 83 0 4 0.1 4.7 3.9 10/09/2004 06:30:00 13.9 1.1 16.1 11.5 13.7 1.3 16.8 10.3 0.4 0 0.4 0.4 41 4 33 305 83 0 83 0 4.1 0.2 4.7 3.9 10/09/2004 06:40:00 13.4 1 15.6 10.7 13.2 1 15.6 10.3 0.4 0 0.4 0.4 40 4 36 305 83 0 83 0 4 0.2 4.7 3.9 10/09/2004 06:50:00 13.6 1.1 16.1 10.3 13.5 1.2 16.4 10.7 0.4 0 0.4 0.4 41 3 39 305 83 0 83 0 3.9 0.2 4.4 3.7 10/09/2004 07:00:00 14.2 1.1 16.4 11.5 14 1.2 16.8 10.7 0.4 0 0.4 0.4 41 3 39 305 82 0 82 0 3.9 0.2 4.4 3.7 10/09/2004 07:10:00 14.7 1.3 17.6 11.1 14.6 1.5 17.2 11.1 0.4 0 0.4 0.4 40 4 44 305 82 0 82 0 3.8 0.1 4.4 3.7 10/09/2004 07:20:00 14.5 1 16.8 11.1 14.3 1.2 16.8 11.5 0.4 0 0.4 0.4 40 4 42 305 82 0 82 0 3.8 0 4.4 3.7 10/09/2004 07:30:00 14.2 1 16.8 11.8 14 1.1 16.8 10.7 0.4 0 0.4 0.4 40 4 40 305 82 0 82 0 3.8 0 4.2 3.7 10/09/2004 07:40:00 14.1 1 16.8 11.1 14 1 16.4 11.1 0.4 0 0.4 0.4 39 4 36 305 82 0 82 0 3.9 0 4.4 3.7 10/09/2004 07:50:00 13.8 1.1 16.1 10.7 13.5 1.2 16.4 10.3 0.4 0 0.4 0.4 39 4 41 305 82 0 82 0 3.9 0 4.2 3.7 10/09/2004 08:00:00 14.8 1 17.2 12.2 14.6 1 18.3 12.2 0.4 0 0.4 0.4 39 4 39 305 82 0 82 0 4 0.2 4.4 3.7 10/09/2004 08:10:00 15.1 1 17.9 12.6 14.9 1.2 17.6 12.2 0.4 0 0.4 0.4 39 4 41 305 81 0 82 0 3.9 0.2 4.4 3.7 10/09/2004 08:20:00 14.3 1.2 16.8 11.5 14 1.2 16.4 11.5 0.4 0 0.4 0.4 38 4 43 305 81 0 82 0 4 0.2 4.4 3.7 10/09/2004 08:30:00 14.5 0.9 17.2 11.8 14.3 1 16.8 11.5 0.4 0 0.4 0.4 40 3 37 305 81 0 81 0 4 0.1 4.7 3.9 10/09/2004 08:40:00 14.1 1.1 16.4 11.1 13.9 1.2 16.4 10.7 0.4 0 0.4 0.4 39 3 39 305 81 0 81 0 4.1 0.2 4.7 3.9 10/09/2004 08:50:00 13.1 1.2 16.1 10.3 12.8 1.3 15.6 9.9 0.4 0 0.4 0.4 40 4 45 305 81 0 81 0 4.2 0.1 4.7 3.9 10/09/2004 09:00:00 14.1 1.1 16.4 11.1 13.8 1.2 16.4 10.7 0.4 0 0.4 0.4 41 4 35 305 81 0 81 0 4.2 0 4.7 4.2 10/09/2004 09:10:00 14.3 1 16.8 11.8 14.1 1 16.8 11.5 0.4 0 0.4 0.4 41 3 45 305 80 0 80 0 4.2 0 4.7 4.2 10/09/2004 09:20:00 13.7 0.9 16.1 11.8 13.5 1 16.4 10.7 0.4 0 0.4 0.4 42 4 40 305 80 0 80 0 4.2 0 4.7 4.2 10/09/2004 09:30:00 13.4 0.9 15.6 10.3 13.3 1 15.3 10.3 0.4 0 0.4 0.4 40 4 38 305 80 0 80 0 4.1 0 4.7 4.2 10/09/2004 09:40:00 13.6 1.2 16.4 10.3 13.5 1.3 16.4 9.9 0.4 0 0.4 0.4 41 4 39 305 79 0 79 0 4.2 0.1 4.7 4.2 10/09/2004 09:50:00 13.8 1.1 16.4 11.1 13.7 1.2 16.4 11.1 0.4 0 0.4 0.4 38 4 41 305 79 0 79 0 4.1 0.1 4.7 3.9 10/09/2004 10:00:00 14.6 1.1 17.2 11.8 14.4 1.2 17.2 11.5 0.4 0 0.4 0.4 38 4 40 305 79 0 79 0 4 0.2 4.7 3.7 10/09/2004 10:10:00 14.3 1.3 17.2 11.1 14.1 1.4 17.2 10.3 0.4 0 0.4 0.4 39 4 41 305 78 0 78 0 3.9 0.2 4.4 3.7 10/09/2004 10:20:00 13.7 1 16.1 11.1 13.5 1 15.6 10.7 0.4 0 0.4 0.4 40 5 38 305 79 0 79 0 4 0.2 4.7 3.7 10/09/2004 10:30:00 15.1 0.8 17.2 12.6 15 1 16.8 12.2 0.4 0 0.4 0.4 37 3 34 305 79 0 79 0 4.1 0.1 4.7 3.9 10/09/2004 10:40:00 14.4 1 16.4 11.8 14.1 1 16.4 11.5 0.4 0 0.4 0.4 41 4 48 305 78 0 78 0 4 0.2 4.7 3.9 10/09/2004 10:50:00 14.7 1.1 17.2 11.8 14.6 1.3 17.2 11.5 0.4 0 0.4 0.4 38 4 34 305 78 0 78 0 4.1 0.2 4.7 3.9 10/09/2004 11:00:00 15 1.1 17.6 11.8 14.7 1.2 17.2 11.5 0.4 0 0.4 0.4 39 4 39 305 77 0 77 0 4.1 0.1 4.7 3.9 10/09/2004 11:10:00 15.3 0.9 17.2 12.6 15.1 1 17.2 12.2 0.4 0 0.4 0.4 37 4 43 305 77 0 77 0 4.1 0 4.7 4.2 10/09/2004 11:20:00 16.2 0.9 17.9 13.3 16 1 18.3 12.6 0.4 0 0.4 0.4 36 3 33 305 76 0 76 0 4.2 0 4.7 4.2 10/09/2004 11:30:00 15 0.8 16.8 12.6 14.9 1 16.8 11.8 0.4 0 0.7 0.4 37 3 35 305 75 0 75 0 4.2 0.1 4.7 4.2 10/09/2004 11:40:00 14.3 1 16.8 11.1 14.1 1.2 16.8 11.1 0.4 0 0.4 0.4 42 4 38 305 74 0 75 0 4.2 0.1 4.9 4.2 10/09/2004 11:50:00 14.6 0.9 17.6 12.2 14.3 1 17.2 11.1 0.4 0 0.4 0.4 42 4 41 305 74 0 74 0 4.2 0 4.9 4.2 10/09/2004 12:00:00 14.4 0.9 16.4 12.2 14.2 1 16.4 11.1 0.4 0 0.4 0.4 43 4 42 305 73 0 74 0 4.2 0.1 4.7 4.2 10/09/2004 12:10:00 14.9 1 16.8 11.1 14.8 1.1 17.6 11.1 0.4 0 0.4 0.4 42 3 40 305 73 0 72 0 4 0 4.7 3.9 10/09/2004 12:20:00 14.9 1 16.8 12.2 14.9 1 16.8 11.8 0.4 0 0.4 0.4 40 3 44 305 72 0 73 0 4 0 4.4 3.9 10/09/2004 12:30:00 14.7 1 16.4 11.5 14.5 1.1 16.8 11.5 0.4 0 0.4 0.4 41 3 42 305 72 0 72 0 4 0 4.7 3.9 10/09/2004 12:40:00 14.6 0.8 16.4 12.2 14.6 0.9 16.8 12.2 0.4 0 0.4 0.4 41 3 36 305 71 0 71 0 4 0 4.4 3.9 10/09/2004 12:50:00 14.4 1.1 16.4 11.8 14.2 1.2 16.8 10.7 0.4 0 0.4 0.4 39 3 44 305 70 0 71 0 4 0 4.4 3.9 10/09/2004 13:00:00 14.5 1 16.4 11.5 14.3 1.1 16.8 11.1 0.4 0 0.4 0.4 38 3 36 305 70 0 70 0 4 0.1 4.4 3.9 10/09/2004 13:10:00 13.7 1.2 16.1 10.3 13.6 1.3 16.4 9.9 0.4 0 0.4 0.4 39 4 46 305 69 0 69 0 4 0.1 4.4 3.7 10/09/2004 13:20:00 14 1 16.1 10.7 13.8 1.1 16.1 10.7 0.4 0 0.4 0.4 37 4 35 305 69 0 69 0 4.1 0 4.7 3.9 10/09/2004 13:30:00 14.7 0.8 16.4 12.6 14.6 0.9 16.4 12.2 0.4 0 0.4 0.4 33 3 30 305 68 0 68 0 4 0 4.4 3.9 10/09/2004 13:40:00 14.4 0.9 16.8 11.8 14.3 1 16.4 11.1 0.4 0 0.4 0.4 35 4 38 305 66 0 66 0 4.1 0 4.7 3.9 10/09/2004 13:50:00 14.2 1 16.8 11.8 14.1 1 16.4 10.3 0.4 0 0.4 0.4 33 3 31 305 69 4 65 0 4 0 4.7 3.9 10/09/2004 14:00:00 14.5 1.1 16.8 11.8 14.4 1.2 16.8 11.1 0.4 0 0.4 0.4 32 3 32 305 72 0 72 0 4.1 0.1 4.7 3.9 10/09/2004 14:10:00 14 1 15.6 10.7 13.8 1 16.1 10.7 0.4 0 0.4 0.4 32 3 32 305 71 1 71 0 4.1 0.1 4.7 3.9 10/09/2004 14:20:00 14.5 1 16.4 11.1 14.4 1.2 16.4 11.1 0.4 0 0.4 0.4 32 4 35 305 69 0 70 0 4.2 0.1 4.7 4.2 10/09/2004 14:30:00 14.5 0.8 16.4 11.8 14.2 1 16.4 11.5 0.4 0 0.4 0.4 33 3 32 305 68 0 68 0 4.2 0.1 4.7 4.2 10/09/2004 14:40:00 14.7 1 16.4 11.8 14.5 1.1 16.4 11.1 0.4 0 0.4 0.4 33 3 32 305 68 0 68 0 4.2 0 4.7 4.2 10/09/2004 14:50:00 14.9 0.8 17.2 13 14.8 1 17.2 11.5 0.4 0 0.4 0.4 36 4 41 305 69 0 70 0 4.1 0.1 4.7 3.9 10/09/2004 15:00:00 14.6 1.2 17.2 11.1 14.4 1.2 17.2 10.7 0.4 0 0.4 0.4 38 4 35 305 70 0 69 0 4.1 0.1 4.7 3.9 10/09/2004 15:10:00 15.3 1.2 17.6 11.5 15.2 1.2 17.2 10.7 0.4 0 0.4 0.4 38 4 36 305 69 0 69 0 4 0.1 4.7 3.9 10/09/2004 15:20:00 15.5 1.3 17.9 11.5 15.2 1.5 17.9 11.5 0.4 0 0.4 0.4 41 4 41 305 67 1 68 0 3.9 0.1 4.4 3.7 10/09/2004 15:30:00 15 1.1 17.2 11.5 14.8 1.2 17.2 11.1 0.4 0 0.4 0.4 41 4 43 305 66 0 66 0 3.8 0.1 4.4 3.7 10/09/2004 15:40:00 14.1 0.9 16.1 11.5 13.9 1 16.1 10.7 0.4 0 0.4 0.4 36 5 38 305 67 0 67 0 3.8 0.1 4.4 3.7 10/09/2004 15:50:00 13.7 1 15.6 11.5 13.6 1 15.6 10.3 0.4 0 0.4 0.4 33 3 31 305 67 1 67 0 3.9 0.2 4.4 3.7 10/09/2004 16:00:00 14.2 0.8 15.6 11.8 14.2 0.9 16.4 11.8 0.4 0 0.4 0.4 35 4 36 305 61 1 62 0 3.9 0.2 4.4 3.7 10/09/2004 16:10:00 13.4 0.9 15.3 10.3 13.2 1 15.3 9.9 0.4 0 0.4 0.4 34 4 34 305 64 2 63 0 3.8 0.1 4.4 3.7 10/09/2004 16:20:00 13.6 1.1 15.6 10.7 13.4 1.2 16.1 10.7 0.4 0 0.4 0.4 33 4 37 305 92 13 98 0 3.8 0.1 4.4 3.7 10/09/2004 16:30:00 13.3 1.3 16.1 9.9 13.1 1.3 15.6 9.5 0.4 0 0.4 0.4 30 4 31 305 105 1 104 0 3.8 0 4.4 3.7 10/09/2004 16:40:00 14.1 1.1 16.4 11.1 14.1 1.2 16.8 9.9 0.4 0 0.4 0.4 33 4 32 305 105 0 105 0 3.7 0 4.4 3.7 10/09/2004 16:50:00 13.5 0.9 15.3 10.3 13.3 1 15.6 10.3 0.4 0 0.4 0.4 34 4 33 305 104 1 104 0 3.8 0 4.2 3.7 10/09/2004 17:00:00 13.4 1 15.6 9.9 13.3 1.1 15.6 9.9 0.4 0 0.4 0.4 35 4 32 305 102 1 104 0 3.7 0 4.2 3.7 10/09/2004 17:10:00 13.7 1 16.1 11.1 13.6 1 16.4 10.7 0.4 0 0.4 0.4 35 4 39 305 101 0 101 0 3.7 0 4.2 3.4 10/09/2004 17:20:00 13.4 1 16.4 10.7 13.4 1 16.4 10.7 0.4 0 0.4 0.4 34 3 36 305 101 0 101 0 3.6 0 4.2 3.4 10/09/2004 17:30:00 13 1.1 15.6 9.5 12.9 1.2 15.6 9.5 0.4 0 0.4 0.4 34 4 33 305 100 0 100 0 3.7 0 4.2 3.4 10/09/2004 17:40:00 12.7 1.1 14.9 10.3 12.6 1.1 14.9 9.5 0.4 0 0.4 0.4 34 4 33 305 100 0 101 0 3.7 0 4.2 3.4 10/09/2004 17:50:00 13.5 1.1 16.1 10.7 13.3 1.1 16.4 9.9 0.4 0 0.4 0.4 32 3 34 305 101 0 100 0 3.8 0 4.4 3.7 10/09/2004 18:00:00 14.2 1 16.4 11.5 14.1 1.1 16.8 10.7 0.4 0 0.4 0.4 29 3 27 305 100 0 100 0 3.9 0.1 4.4 3.7 10/09/2004 18:10:00 14.1 1.1 17.2 10.7 14 1.2 16.8 9.9 0.4 0 0.4 0.4 31 3 30 305 100 0 100 0 4 0 4.4 3.7 10/09/2004 18:20:00 14.1 0.8 16.1 12.2 13.9 1 16.1 11.1 0.4 0 0.4 0.4 32 3 31 305 99 0 99 0 4.1 0 4.7 3.9 10/09/2004 18:30:00 14.2 1.1 16.8 11.5 14 1.1 16.8 10.7 0.4 0 0.4 0.4 35 4 32 305 98 0 98 0 4.3 0 4.7 4.2 10/09/2004 18:40:00 13.8 1 16.4 11.5 13.6 1.1 16.1 10.7 0.4 0 0.4 0.4 34 4 35 305 96 1 95 0 4.4 0.1 4.9 4.2 10/09/2004 18:50:00 14.2 1 16.4 11.5 14.1 1.1 16.4 11.1 0.4 0 0.4 0.4 34 3 30 305 94 1 93 0 4.4 0.1 4.9 4.2 10/09/2004 19:00:00 13.8 1.2 16.4 11.1 13.6 1.2 16.4 10.3 0.4 0 0.4 0.4 36 4 30 305 91 1 89 0 4.4 0.1 4.9 4.2 10/09/2004 19:10:00 14.4 1 16.8 11.8 14 1.1 16.4 11.1 0.4 0 0.4 0.4 36 4 33 305 76 10 88 0 4.4 0.1 4.9 4.4 10/09/2004 19:20:00 14.1 0.9 16.4 11.5 13.9 1 16.4 10.3 0.4 0 0.4 0.4 34 3 31 305 56 4 62 0 4.4 0.1 4.9 4.4 10/09/2004 19:30:00 14.1 1.2 16.8 11.5 13.9 1.3 16.8 10.3 0.4 0 0.4 0.4 34 4 33 305 47 0 47 0 4.4 0.2 4.9 4.4 10/09/2004 19:40:00 14.7 1 17.2 11.8 14.4 1.2 17.9 11.1 0.4 0 0.4 0.4 33 3 29 305 35 13 21 0 4.4 0.1 4.9 4.4 10/09/2004 19:50:00 14.9 0.9 17.2 12.2 14.7 1 16.8 11.5 0.4 0 0.4 0.4 33 4 38 305 21 0 21 0 4.5 0.1 4.9 4.4 10/09/2004 20:00:00 14.1 1 16.4 11.8 13.9 1.1 16.4 11.5 0.4 0 0.4 0.4 31 4 30 305 21 0 21 0 4.4 0.1 4.9 4.4 10/09/2004 20:10:00 14.2 1 16.4 11.5 14 1 16.1 11.5 0.4 0 0.4 0.4 30 3 31 305 21 0 21 0 4.5 0.2 4.9 4.4 10/09/2004 20:20:00 14.1 0.9 16.4 11.8 13.9 1 16.1 11.1 0.4 0 0.4 0.4 31 3 29 305 20 0 20 0 4.4 0.2 4.9 4.4 10/09/2004 20:30:00 14 0.8 16.1 11.8 13.7 0.8 16.1 11.1 0.4 0 0.4 0.4 32 3 30 305 20 0 20 0 4.4 0.1 4.9 4.2 10/09/2004 20:40:00 15 0.8 17.2 12.6 14.7 1 17.6 11.5 0.4 0 0.4 0.4 33 3 33 305 20 0 20 0 4.4 0.1 4.9 4.4 10/09/2004 20:50:00 14.6 1 16.8 12.2 14.4 1 16.8 11.5 0.4 0 0.4 0.4 33 3 37 305 20 0 20 0 4.4 0.1 4.9 4.4 10/09/2004 21:00:00 14.5 1 17.6 11.8 14.3 1.1 16.8 11.5 0.4 0 0.4 0.4 33 4 42 305 19 0 19 0 4.4 0.1 4.9 4.4 10/09/2004 21:10:00 14.3 1.3 17.6 11.1 14 1.3 17.2 10.7 0.4 0 0.4 0.4 33 3 35 305 19 0 20 0 4.4 0 4.9 4.4 10/09/2004 21:20:00 14.8 1.1 17.6 12.2 14.5 1.1 17.2 11.8 0.4 0 0.4 0.4 33 4 36 305 19 0 19 0 4.4 0 4.9 4.4 10/09/2004 21:30:00 15.1 1.4 17.9 11.1 14.8 1.5 17.9 10.7 0.4 0 0.4 0.4 33 4 29 305 19 0 19 0 4.4 0 4.9 4.4 10/09/2004 21:40:00 15.6 1.2 17.9 12.2 15.3 1.2 17.6 11.8 0.4 0 0.4 0.4 35 3 39 305 18 0 18 0 4.4 0 4.9 4.4 10/09/2004 21:50:00 14.4 1 16.8 11.5 14.1 1 16.8 11.5 0.4 0 0.4 0.4 37 4 41 305 18 0 18 0 4.4 0 4.7 4.4 10/09/2004 22:00:00 14.5 1.1 16.8 11.5 14.3 1.2 16.8 11.5 0.4 0 0.4 0.4 34 4 32 305 18 0 18 0 4.4 0.1 4.9 4.4 10/09/2004 22:10:00 14.2 1 17.2 11.5 13.9 1 16.1 11.5 0.4 0 0.4 0.4 35 4 35 305 17 0 18 0 4.4 0.1 4.9 4.4 10/09/2004 22:20:00 14.8 1 17.2 11.5 14.5 1.2 17.2 10.7 0.4 0 0.4 0.4 35 3 37 305 17 0 17 0 4.4 0 4.9 4.4 10/09/2004 22:30:00 15.6 1.3 17.9 12.6 15.3 1.4 18.3 11.5 0.4 0 0.4 0.4 36 3 33 305 16 0 16 0 4.4 0 4.9 4.4 10/09/2004 22:40:00 14.8 1 17.2 11.8 14.6 1 17.2 11.5 0.4 0 0.4 0.4 34 3 32 305 15 0 15 0 4.4 0 4.9 4.4 10/09/2004 22:50:00 15.4 1 17.6 13 15.2 1 17.6 12.6 0.4 0 0.4 0.4 35 3 33 305 14 0 15 0 4.3 0 4.7 4.2 10/09/2004 23:00:00 14.9 1.2 17.9 12.2 14.7 1.3 18.3 11.5 0.4 0 0.4 0.4 33 4 35 305 13 0 12 0 4.2 0.1 4.7 4.2 10/09/2004 23:10:00 14.8 1.1 17.6 11.8 14.6 1.2 17.9 11.8 0.4 0 0.4 0.4 35 4 29 305 11 1 11 0 4 0 4.4 3.9 10/09/2004 23:20:00 15.6 1.1 17.9 12.2 15.3 1.1 17.2 12.2 0.4 0 0.4 0.4 35 3 37 305 8 1 9 0 4 0.1 4.4 3.9 10/09/2004 23:30:00 15.2 1.3 17.9 11.8 14.9 1.3 17.9 11.5 0.4 0 0.4 0.4 33 4 33 305 6 1 7 0 4 0.2 4.7 3.9 10/09/2004 23:40:00 15.7 1.2 17.6 12.6 15.6 1.1 17.6 13 0.4 0 0.4 0.4 31 3 35 305 5 0 5 0 4 0.2 4.4 3.7 10/09/2004 23:50:00 15.5 1.1 18.3 12.6 15.2 1.2 17.9 11.8 0.4 0 0.4 0.4 32 4 35 305 4 0 4 0 4 0.2 4.4 3.7 10/10/2004 00:00:00 15.5 1.1 17.9 12.6 15.2 1.2 17.6 11.5 0.4 0 0.4 0.4 30 3 28 305 4 0 4 0 3.9 0.1 4.4 3.7 10/10/2004 00:10:00 15.1 1 17.2 12.2 14.9 1.2 17.6 11.1 0.4 0 0.4 0.4 30 3 32 305 3 0 3 0 3.9 0.1 4.4 3.7 10/10/2004 00:20:00 14.8 1.1 17.2 11.5 14.6 1.3 17.2 10.7 0.4 0 0.4 0.4 30 3 31 305 3 0 3 0 3.9 0.1 4.4 3.7 10/10/2004 00:30:00 14.7 1.2 17.6 11.1 14.5 1.2 17.2 11.1 0.4 0 0.4 0.4 30 3 30 305 3 0 3 0 4 0 4.4 3.9 10/10/2004 00:40:00 14.7 1 16.8 11.8 14.4 1.1 16.8 11.5 0.4 0 0.4 0.4 31 4 31 305 3 0 3 0 4 0 4.4 3.9 10/10/2004 00:50:00 15.2 1 17.6 12.6 14.9 1.1 17.9 11.5 0.4 0 0.4 0.4 30 4 30 305 3 0 3 0 4.2 0 4.7 4.2 10/10/2004 01:00:00 15.4 1.3 18.3 12.2 15.1 1.4 18.3 11.1 0.4 0 0.4 0.4 31 3 36 305 3 0 3 0 4.2 0 4.4 4.2 10/10/2004 01:10:00 15 1.1 17.2 12.2 14.7 1.2 17.6 11.1 0.4 0 0.4 0.4 31 4 26 305 3 0 3 0 4.1 0 4.4 4.2 10/10/2004 01:20:00 15.2 1 17.6 11.8 14.9 1.1 17.6 11.5 0.4 0 0.4 0.4 30 3 35 305 3 0 3 0 4.1 0 4.4 4.2 10/10/2004 01:30:00 14.9 1.1 17.6 11.5 14.7 1.2 17.6 10.7 0.4 0 0.4 0.4 31 4 31 305 3 0 2 0 4.1 0.1 4.7 4.2 10/10/2004 01:40:00 15.3 1.1 18.3 12.6 15.1 1.3 18.3 12.2 0.4 0 0.4 0.4 33 4 32 305 2 0 2 0 4.1 0.1 4.7 3.9 10/10/2004 01:50:00 15.7 0.9 17.9 13 15.4 1 17.9 12.6 0.4 0 0.4 0.4 33 4 35 305 2 0 2 0 4.1 0.1 4.7 3.9 10/10/2004 02:00:00 15.5 1.2 17.6 11.8 15.2 1.3 17.6 11.5 0.4 0 0.4 0.4 34 4 39 305 2 0 2 0 4 0.2 4.7 3.9 10/10/2004 02:10:00 15.5 1.1 18.3 12.2 15.2 1.2 17.9 11.8 0.4 0 0.4 0.4 34 4 36 305 2 0 2 0 4 0.2 4.4 3.7 10/10/2004 02:20:00 15.7 1.1 17.9 12.6 15.5 1.2 18.3 12.6 0.4 0 0.4 0.4 32 3 36 305 2 0 2 0 4.1 0.2 4.7 3.9 10/10/2004 02:30:00 15.8 1.1 18.3 12.6 15.5 1.2 18.7 12.6 0.4 0 0.4 0.4 31 4 29 305 2 0 2 0 4.1 0.1 4.7 3.9 10/10/2004 02:40:00 15.8 1 17.9 13 15.6 1.2 17.9 12.2 0.4 0 0.4 0.4 31 3 35 305 2 0 2 0 4.2 0.2 4.7 3.9 10/10/2004 02:50:00 16.2 1.3 19.1 12.6 15.8 1.5 19.1 11.8 0.4 0 0.4 0.4 33 3 36 305 2 0 2 0 4.2 0 4.7 4.2 10/10/2004 03:00:00 16.4 1.2 18.7 13 16 1.3 18.7 12.6 0.4 0 0.4 0.4 33 4 28 305 2 0 2 0 4.3 0 4.7 4.2 10/10/2004 03:10:00 16.1 1.5 19.1 12.6 15.8 1.5 18.7 11.8 0.4 0 0.4 0.4 32 4 34 305 2 0 2 0 4.2 0 4.7 4.2 10/10/2004 03:20:00 16.2 1 18.3 13.3 15.9 1.2 18.3 12.6 0.4 0 0.4 0.4 32 3 33 305 2 0 2 0 4.2 0 4.7 4.2 10/10/2004 03:30:00 15.5 1.3 18.7 11.8 15.3 1.3 18.3 11.8 0.4 0 0.4 0.4 32 4 33 305 2 0 2 0 4.3 0.1 4.9 4.2 10/10/2004 03:40:00 15.7 1.1 18.7 12.6 15.4 1.2 17.9 11.8 0.4 0 0.4 0.4 31 4 27 305 2 0 2 0 4.3 0 4.9 4.2 10/10/2004 03:50:00 15.7 1.3 18.3 13 15.4 1.4 18.7 12.2 0.4 0 0.4 0.4 32 3 29 305 2 0 2 0 4.2 0 4.7 4.2 10/10/2004 04:00:00 15.5 1.1 17.9 12.2 15.4 1.1 18.3 12.2 0.4 0 0.4 0.4 30 3 27 305 1 0 1 0 4.2 0 4.7 4.2 10/10/2004 04:10:00 16 1.1 18.3 12.6 15.7 1.2 18.3 12.2 0.4 0 0.4 0.4 30 3 30 305 1 0 1 0 4.2 0 4.4 4.2 10/10/2004 04:20:00 15.8 1.5 18.7 11.8 15.5 1.6 18.3 11.1 0.4 0 0.4 0.4 32 4 33 305 1 0 1 0 4.1 0 4.4 4.2 10/10/2004 04:30:00 16.1 1.3 19.5 12.6 15.7 1.3 18.3 12.6 0.4 0 0.4 0.4 30 4 35 305 2 0 2 0 4.1 0 4.7 4.2 10/10/2004 04:40:00 16 1 18.3 13.3 15.7 1.1 18.3 13 0.4 0 0.4 0.4 30 4 33 305 2 0 2 0 4.1 0 4.4 4.2 10/10/2004 04:50:00 15.7 1.3 18.7 11.8 15.4 1.4 19.1 11.5 0.4 0 0.4 0.4 32 4 32 305 2 0 2 0 4.2 0 4.7 4.2 10/10/2004 05:00:00 16.9 1.2 19.5 13.3 16.5 1.3 19.5 12.2 0.4 0 0.4 0.4 31 4 25 305 2 0 2 0 4.3 0 4.7 4.2 10/10/2004 05:10:00 16.5 1.1 19.5 13 16.2 1.2 19.5 12.6 0.4 0 0.4 0.4 31 4 30 305 2 0 1 0 4.3 0 4.9 4.2 10/10/2004 05:20:00 16.5 1.3 19.5 13.3 16.2 1.5 19.5 11.8 0.4 0 0.4 0.4 32 4 30 305 2 0 2 0 4.3 0 4.9 4.2 10/10/2004 05:30:00 17.5 1.3 20.6 13 17.2 1.4 20.6 12.6 0.4 0 0.4 0.4 32 4 30 305 1 0 1 0 4.3 0 4.9 4.2 10/10/2004 05:40:00 16.5 1.4 20.2 12.2 16.4 1.5 20.2 12.2 0.4 0 0.4 0.4 31 4 30 305 1 0 1 0 4.2 0 4.7 4.2 10/10/2004 05:50:00 17.3 1.3 20.2 13.7 17.1 1.3 19.9 13.3 0.4 0 0.4 0.4 33 4 33 305 1 0 1 0 4.2 0 4.7 4.2 10/10/2004 06:00:00 16.8 1.2 20.2 13.7 16.6 1.3 20.6 12.6 0.4 0 0.4 0.4 32 4 33 305 1 0 1 0 4.2 0 4.7 4.2 10/10/2004 06:10:00 16.6 1.2 19.1 13.3 16.5 1.3 19.1 13 0.4 0 0.4 0.4 35 4 32 305 1 0 1 0 4.2 0 4.7 4.2 10/10/2004 06:20:00 16.7 1.5 20.2 12.2 16.4 1.5 20.2 12.2 0.4 0 0.4 0.4 34 4 31 305 1 0 1 0 4.2 0 4.7 4.2 10/10/2004 06:30:00 16.8 1.4 21 13 16.6 1.4 19.9 13 0.4 0 0.4 0.4 32 4 36 305 1 0 1 0 4.3 0 4.7 4.2 10/10/2004 06:40:00 17 1.5 19.5 13 16.6 1.5 19.5 12.6 0.4 0 0.4 0.4 30 4 30 305 2 0 2 0 4.2 0.1 4.7 4.2 10/10/2004 06:50:00 16.9 1.2 19.9 13.7 16.6 1.3 19.5 13.3 0.4 0 0.4 0.4 29 4 30 305 2 0 2 0 4.1 0.1 4.7 3.9 10/10/2004 07:00:00 17.6 1.3 21 13 17.2 1.5 21 13.7 0.4 0 0.4 0.4 30 4 29 305 2 0 2 0 4 0.2 4.7 3.9 10/10/2004 07:10:00 17.1 1.4 20.6 12.6 16.8 1.5 20.6 12.6 0.4 0 0.4 0.4 30 4 29 305 2 0 2 0 4 0.2 4.4 3.7 10/10/2004 07:20:00 16.8 1.3 19.9 13 16.3 1.4 19.5 12.2 0.4 0 0.4 0.4 30 5 33 305 2 0 2 0 4 0.1 4.7 3.9 10/10/2004 07:30:00 17 1.2 19.9 13.7 16.6 1.3 19.5 12.2 0.4 0 0.4 0.4 29 4 23 305 3 0 2 0 4 0.1 4.7 3.9 10/10/2004 07:40:00 17.1 1.7 21.8 13 16.9 1.8 21.4 12.2 0.4 0 0.4 0.4 29 4 26 305 3 0 3 0 3.9 0.2 4.4 3.7 10/10/2004 07:50:00 18.2 1.4 21.4 14.1 17.8 1.4 21.4 14.1 0.4 0 0.4 0.4 27 4 26 305 3 0 3 0 3.9 0.1 4.4 3.7 10/10/2004 08:00:00 18.1 1.2 21.4 14.9 17.7 1.2 20.6 14.9 0.4 0 0.4 0.4 29 4 32 305 3 0 3 0 3.9 0.2 4.4 3.7 10/10/2004 08:10:00 17.8 1.3 20.6 14.1 17.5 1.3 21 13.7 0.4 0 0.4 0.4 28 4 26 305 3 0 3 0 3.9 0.2 4.4 3.7 10/10/2004 08:20:00 17.5 1.5 21 14.1 17.2 1.4 20.6 13.7 0.4 0 0.4 0.4 26 4 27 305 3 0 3 0 3.9 0.1 4.4 3.7 10/10/2004 08:30:00 18.3 1.3 21 14.1 18 1.4 21 14.1 0.4 0 0.4 0.4 28 4 28 305 3 0 3 0 3.9 0.1 4.4 3.7 10/10/2004 08:40:00 17.9 1.5 21.4 13.7 17.6 1.5 20.6 13 0.4 0 0.4 0.4 28 4 26 305 3 0 4 0 3.9 0.1 4.4 3.7 10/10/2004 08:50:00 17.9 1.4 21 13.3 17.5 1.5 21 13.3 0.4 0 0.4 0.4 27 4 19 305 4 0 4 0 3.9 0.1 4.4 3.7 10/10/2004 09:00:00 18.6 1.5 21.8 14.5 18.2 1.4 21.4 14.5 0.4 0 0.4 0.4 28 4 29 305 4 0 4 0 3.8 0 4.4 3.7 10/10/2004 09:10:00 18.2 1.5 21.4 13.3 17.8 1.6 21 12.6 0.4 0 0.4 0.4 28 4 26 305 4 0 4 0 3.8 0 4.4 3.7 10/10/2004 09:20:00 18.7 1.7 22.1 14.5 18.4 1.7 21.8 13.7 0.4 0 0.4 0.4 30 4 30 305 4 0 4 0 3.8 0 4.4 3.7 10/10/2004 09:30:00 18.4 1.7 21.8 13 18 1.7 22.1 13 0.4 0 0.4 0.4 29 4 28 305 4 0 4 0 3.9 0.1 4.4 3.7 10/10/2004 09:40:00 18 1.7 21.4 13.3 17.6 1.7 21.4 13.3 0.4 0 0.4 0.4 28 4 25 305 4 0 4 0 3.8 0 4.4 3.7 10/10/2004 09:50:00 18.8 1.6 22.1 14.5 18.4 1.7 22.6 13 0.4 0 0.4 0.4 29 4 32 305 4 0 4 0 3.8 0.1 4.4 3.7 10/10/2004 10:00:00 18.5 1.5 22.1 14.1 18.1 1.5 22.1 13.7 0.4 0 0.4 0.4 28 5 30 305 4 0 4 0 3.8 0 4.2 3.7 10/10/2004 10:10:00 18.3 1.7 22.6 13.7 18 1.7 22.6 13.7 0.4 0 0.4 0.4 30 5 27 305 4 0 4 0 3.9 0.1 4.4 3.7 10/10/2004 10:20:00 19 1.5 23.7 15.3 18.7 1.6 23.3 14.9 0.4 0 0.4 0.4 30 4 28 305 4 0 4 0 3.9 0.1 4.4 3.7 10/10/2004 10:30:00 20 1.7 23.3 14.5 19.5 1.7 22.9 14.9 0.4 0 0.4 0.4 31 4 33 305 4 0 4 0 3.9 0.1 4.4 3.7 10/10/2004 10:40:00 19.2 1.6 22.6 15.3 18.7 1.7 22.6 14.5 0.4 0 0.4 0.4 32 5 36 305 4 0 4 0 3.9 0.2 4.4 3.7 10/10/2004 10:50:00 18.6 1.6 22.6 14.9 18.2 1.7 23.3 14.1 0.4 0 0.4 0.4 32 5 35 305 4 0 4 0 3.9 0.2 4.4 3.7 10/10/2004 11:00:00 19.4 1.7 22.6 15.3 19.1 1.9 22.6 14.5 0.4 0 0.4 0.4 33 4 36 305 4 0 4 0 3.9 0.2 4.4 3.7 10/10/2004 11:10:00 18.5 1.5 22.1 14.9 18.1 1.6 22.1 13.3 0.4 0 0.4 0.4 33 4 34 305 4 0 5 0 3.8 0.1 4.4 3.7 10/10/2004 11:20:00 19.2 1.9 23.7 13.7 18.9 2 23.7 13.7 0.4 0 0.4 0.4 35 4 42 305 5 0 5 0 3.8 0.1 4.4 3.7 10/10/2004 11:30:00 19.2 1.5 22.9 14.1 18.9 1.6 22.6 13.7 0.4 0 0.4 0.4 34 4 33 305 5 0 5 0 3.8 0.1 4.4 3.7 10/10/2004 11:40:00 19.4 1.4 22.6 15.6 18.9 1.5 22.6 15.3 0.4 0 0.4 0.4 35 4 31 305 5 0 5 0 3.8 0.1 4.4 3.7 10/10/2004 11:50:00 18.2 1.7 22.9 13.7 17.8 1.8 22.6 13.3 0.4 0 0.4 0.4 34 5 35 305 5 0 5 0 3.9 0.2 4.4 3.7 10/10/2004 12:00:00 18.7 1.7 22.9 14.9 18.4 1.7 22.1 14.1 0.4 0 0.4 0.4 35 4 34 305 5 0 5 0 4 0.2 4.4 3.7 10/10/2004 12:10:00 18.7 1.7 22.6 14.5 18.4 1.7 22.1 14.5 0.4 0 0.4 0.4 36 4 39 305 5 0 5 0 4 0.2 4.4 3.7 10/10/2004 12:20:00 18 1.8 22.9 13.3 17.7 1.8 21.8 13.3 0.4 0 0.4 0.4 37 5 38 305 5 0 5 0 4 0.2 4.4 3.7 10/10/2004 12:30:00 18.7 1.5 22.6 14.1 18.4 1.5 21.8 13.7 0.4 0 0.4 0.4 36 4 36 305 5 0 5 0 4 0.2 4.4 3.7 10/10/2004 12:40:00 18.4 1.3 22.1 14.5 18.1 1.5 21.4 13.3 0.4 0 0.4 0.4 36 4 31 305 5 0 5 0 3.9 0.1 4.4 3.7 10/10/2004 12:50:00 18.3 1.5 22.1 13.7 17.9 1.6 22.6 13.7 0.4 0 0.4 0.4 36 5 41 305 6 0 6 0 3.9 0.1 4.4 3.7 10/10/2004 13:00:00 18.4 1.7 21.8 14.1 17.9 1.8 21.4 13.3 0.4 0 0.4 0.4 36 4 35 305 6 0 6 0 3.9 0.1 4.4 3.7 10/10/2004 13:10:00 17.8 1.7 22.1 13.3 17.4 1.8 22.1 13 0.4 0 0.4 0.4 36 5 38 305 6 0 6 0 3.9 0.1 4.4 3.7 10/10/2004 13:20:00 18 1.7 21.8 13.7 17.6 1.8 21.8 13.3 0.4 0 0.4 0.4 36 5 38 305 6 0 6 0 3.9 0.1 4.4 3.7 10/10/2004 13:30:00 17.9 1.8 22.1 13.7 17.5 1.9 22.6 13 0.4 0 0.4 0.4 35 4 32 305 6 0 6 0 3.9 0.2 4.4 3.7 10/10/2004 13:40:00 17.4 1.7 21 14.1 17.1 1.8 21.4 13.3 0.4 0 0.4 0.4 36 5 35 305 6 0 6 0 3.9 0.1 4.4 3.7 10/10/2004 13:50:00 18 1.7 21.4 14.1 17.7 1.9 21.4 13 0.4 0 0.4 0.4 36 4 31 305 6 0 6 0 3.9 0.1 4.4 3.7 10/10/2004 14:00:00 16.8 1.5 20.2 12.6 16.5 1.7 20.2 11.5 0.4 0 0.4 0.4 37 5 33 305 6 0 6 0 4 0.1 4.4 3.7 10/10/2004 14:10:00 16.8 1.4 20.2 13.7 16.5 1.5 19.9 13 0.4 0 0.4 0.4 36 5 38 305 6 0 6 0 4 0 4.4 3.9 10/10/2004 14:20:00 16.7 1.5 21 13 16.3 1.6 19.9 12.2 0.4 0 0.4 0.4 35 4 33 305 6 0 6 0 4 0 4.7 3.9 10/10/2004 14:30:00 16.7 1.3 19.5 13.3 16.4 1.3 19.5 12.6 0.4 0 0.4 0.4 36 4 30 305 6 0 6 0 4.1 0.1 4.7 4.2 10/10/2004 14:40:00 16 1.3 18.7 12.2 15.7 1.4 18.7 11.8 0.4 0 0.4 0.4 35 5 37 305 6 0 6 0 4.2 0 4.7 4.2 10/10/2004 14:50:00 16.6 1.4 19.9 13 16.3 1.5 20.2 12.2 0.4 0 0.4 0.4 35 4 33 305 6 0 6 0 4.3 0 4.7 4.2 10/10/2004 15:00:00 15.9 1.5 20.2 12.6 15.6 1.5 20.2 12.2 0.4 0 0.4 0.4 35 4 33 305 6 0 6 0 4.2 0 4.7 4.2 10/10/2004 15:10:00 16.7 1.4 19.5 12.6 16.5 1.5 19.9 12.2 0.4 0 0.4 0.4 36 3 37 305 6 0 6 0 4.3 0 4.9 4.2 10/10/2004 15:20:00 16.7 1.2 19.5 13.3 16.5 1.2 19.1 12.6 0.4 0 0.4 0.4 36 4 34 305 6 0 6 0 4.2 0 4.7 4.2 10/10/2004 15:30:00 16.3 1.2 19.1 13 16.1 1.3 19.5 11.8 0.4 0 0.4 0.4 36 5 33 305 7 0 7 0 4.2 0 4.7 4.2 10/10/2004 15:40:00 16.4 1.3 19.5 12.6 16.1 1.3 19.5 11.5 0.4 0 0.4 0.4 34 4 32 305 7 0 7 0 4.3 0 4.9 4.2 10/10/2004 15:50:00 15.5 1.3 18.3 11.8 15.2 1.3 18.3 11.5 0.4 0 0.4 0.4 35 5 35 305 7 0 7 0 4.3 0 4.9 4.2 10/10/2004 16:00:00 15.8 1.5 19.1 12.6 15.4 1.5 18.7 11.1 0.4 0 0.4 0.4 34 4 33 305 7 0 7 0 4.4 0.1 4.9 4.2 10/10/2004 16:10:00 15.7 1.1 18.7 12.6 15.4 1.3 18.3 11.8 0.4 0 0.4 0.4 31 4 35 305 7 0 7 0 4.4 0.1 4.9 4.2 10/10/2004 16:20:00 15.6 1 18.3 12.6 15.4 1.1 17.6 11.5 0.4 0 0.4 0.4 31 3 32 305 7 0 7 0 4.4 0.1 4.9 4.2 10/10/2004 16:30:00 14.5 1.2 17.2 11.1 14.2 1.3 16.8 10.7 0.4 0 0.4 0.4 32 4 33 305 7 0 7 0 4.5 0.1 4.9 4.4 10/10/2004 16:40:00 14.3 1.3 16.8 10.3 14.1 1.3 16.8 9.1 0.4 0 0.4 0.4 33 4 27 305 7 0 7 0 4.5 0.1 5.2 4.4 10/10/2004 16:50:00 13.9 1 16.8 10.7 13.6 1.1 16.4 10.7 0.4 0 0.4 0.4 32 4 30 305 7 0 7 0 4.6 0.1 5.2 4.4 10/10/2004 17:00:00 13.2 1.2 15.6 9.1 13 1.3 15.6 8.4 0.4 0 0.4 0.4 34 4 35 305 7 0 7 0 4.7 0.1 5.4 4.4 10/10/2004 17:10:00 13 1 15.6 10.3 12.7 1.1 15.3 9.1 0.4 0 0.4 0.4 33 3 39 305 7 0 7 0 4.8 0.1 5.4 4.7 10/10/2004 17:20:00 12.3 0.6 13.7 10.3 12 0.8 14.1 9.5 0.4 0 0.4 0.4 33 3 37 305 7 0 8 0 4.9 0.1 5.4 4.7 10/10/2004 17:30:00 11.8 0.9 14.1 9.9 11.5 1 13.7 8.8 0.4 0 0.4 0.4 35 3 34 305 8 0 7 0 5 0.2 5.6 4.9 10/10/2004 17:40:00 11.6 0.6 13 9.5 11.3 0.7 13 9.1 0.4 0 0.4 0.4 35 3 31 305 8 0 8 0 5.2 0.1 5.6 4.9 10/10/2004 17:50:00 11.3 0.8 13 9.1 11 0.8 13.3 9.1 0.4 0 0.4 0.4 37 4 35 305 8 0 8 0 5.3 0.1 5.9 5.2 10/10/2004 18:00:00 10.9 0.6 12.2 9.5 10.7 0.6 12.2 8.8 0.4 0 0.4 0.4 39 4 40 305 8 0 8 0 5.3 0 5.9 5.2 10/10/2004 18:10:00 10.5 0.6 11.8 8 10.1 0.7 11.8 8.4 0.4 0 0.4 0.4 42 4 40 305 8 0 8 0 5.3 0 5.9 5.2 10/10/2004 18:20:00 10.4 0.6 11.8 8.4 10.1 0.7 11.8 8.4 0.4 0 0.4 0.4 44 4 48 305 8 0 8 0 5.3 0 5.9 5.2 10/10/2004 18:30:00 10.1 0.6 11.8 8.4 9.7 0.7 11.5 8 0.4 0 0.4 0.4 46 4 44 305 8 0 8 0 5.3 0 5.9 5.2 10/10/2004 18:40:00 9.5 0.5 11.1 8 9.2 0.6 11.1 7.6 0.4 0 0.4 0.4 49 4 47 305 8 0 8 0 5.5 0.1 5.9 5.4 10/10/2004 18:50:00 9.4 0.9 11.5 7.2 9.1 1 12.2 6.8 0.4 0 0.4 0.4 56 5 58 305 8 0 8 0 5.5 0.1 5.9 5.4 10/10/2004 19:00:00 9.9 0.6 11.1 8.4 9.6 0.6 11.5 7.6 0.4 0 0.4 0.4 61 4 57 305 8 0 8 0 5.6 0.1 5.9 5.4 10/10/2004 19:10:00 8.9 0.5 10.3 7.6 8.7 0.6 9.9 6.5 0.4 0 0.4 0.4 61 3 61 305 8 0 8 0 5.5 0.1 5.9 5.4 10/10/2004 19:20:00 9 0.5 10.3 7.6 8.9 0.5 9.9 7.2 0.4 0 0.4 0.4 64 4 64 305 8 0 8 0 5.6 0.1 6.1 5.4 10/10/2004 19:30:00 8.8 0.7 10.7 7.2 8.5 0.7 10.7 6.8 0.4 0 0.4 0.4 67 6 64 305 8 0 8 0 5.6 0 6.1 5.6 10/10/2004 19:40:00 8.8 0.6 10.3 7.2 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 69 5 75 305 8 0 8 0 5.8 0 6.1 5.6 10/10/2004 19:50:00 8.6 0.6 10.3 7.2 8.3 0.6 10.3 6.5 0.4 0 0.4 0.4 66 6 68 305 8 0 8 0 5.7 0 6.1 5.6 10/10/2004 20:00:00 8.1 0.9 10.3 5.7 7.9 0.9 10.3 5.7 0.4 0 0.4 0.4 72 6 70 305 8 0 8 0 5.8 0 6.1 5.6 10/10/2004 20:10:00 7.7 0.9 9.9 5.7 7.5 0.8 9.9 5.7 0.4 0 0.4 0.4 68 7 82 305 8 0 8 0 6 0.2 6.4 5.6 10/10/2004 20:20:00 8.7 1 12.2 5.7 8.7 1 11.8 6.1 0.4 0 0.4 0.4 67 7 64 305 8 0 8 0 6.3 0 6.9 6.1 10/10/2004 20:30:00 7.6 1.2 11.1 4.2 7.6 1.3 11.5 4.2 0.4 0 0.4 0.4 67 11 60 305 8 0 8 0 6.4 0 6.9 6.1 10/10/2004 20:40:00 7.4 1.9 11.8 2.3 7.4 1.8 11.5 2.6 0.4 0 0.4 0.4 62 13 56 305 8 0 8 0 6.5 0 6.9 6.4 10/10/2004 20:50:00 7.7 1.5 11.1 4.2 7.7 1.5 11.5 3.8 0.4 0 0.4 0.4 62 12 56 305 8 0 8 0 6.7 0.1 7.2 6.4 10/10/2004 21:00:00 7.5 1.5 11.1 3.8 7.7 1.5 11.5 3.8 0.4 0 0.4 0.4 67 12 71 305 8 0 8 0 6.7 0.1 7.2 6.4 10/10/2004 21:10:00 8.2 1.5 13 3.4 8.2 1.6 13 4.2 0.4 0 0.4 0.4 66 12 52 305 8 0 8 0 6.7 0.1 7.2 6.4 10/10/2004 21:20:00 8.1 1.6 13.7 4.2 8.2 1.4 12.6 5.3 0.4 0 0.4 0.4 62 14 56 305 8 0 8 0 6.6 0 7.2 6.4 10/10/2004 21:30:00 4.5 1.6 8.8 0.7 4.6 1.5 9.1 0.4 0.4 0 0.4 0.4 73 22 74 305 8 0 8 0 6.5 0 6.9 6.4 10/10/2004 21:40:00 4.1 1.3 7.2 0.7 4 1.1 6.5 1.1 0.4 0 0.4 0.4 97 30 116 305 8 0 8 0 6.5 0 7.2 6.4 10/10/2004 21:50:00 1.8 1.4 4.9 0.4 2.3 1.2 6.1 0.4 0.4 0 0.4 0.4 108 47 162 305 8 0 8 0 6.5 0 6.9 6.4 10/10/2004 22:00:00 3.1 1.5 7.2 0.4 3.2 1.2 6.5 0.4 0.4 0 0.4 0.4 115 32 119 305 8 0 8 0 6.5 0 6.9 6.4 10/10/2004 22:10:00 4.7 1.7 9.5 0.4 4.7 1.5 10.7 0.7 0.4 0 0.4 0.4 133 21 148 305 8 0 8 0 6.5 0 6.9 6.4 10/10/2004 22:20:00 4.9 1.4 9.1 1.5 4.7 1.3 8 1.5 0.4 0 0.4 0.4 130 19 123 305 8 0 8 0 6.5 0 6.9 6.4 10/10/2004 22:30:00 4.4 1.7 9.1 0.4 4.2 1.5 8 0.7 0.4 0 0.4 0.4 119 27 126 305 8 0 8 0 6.5 0 6.9 6.4 10/10/2004 22:40:00 5.8 1.7 11.5 2.3 5.6 1.5 9.5 2.3 0.4 0 0.4 0.4 122 16 104 305 8 0 7 0 6.5 0 6.9 6.4 10/10/2004 22:50:00 5.5 1.6 10.3 1.9 5.5 1.6 10.7 1.9 0.4 0 0.4 0.4 122 19 121 305 8 0 7 0 6.5 0 6.9 6.4 10/10/2004 23:00:00 4.4 1.5 8.4 0.7 4.5 1.3 8.4 1.9 0.4 0 0.4 0.4 126 22 156 305 7 0 7 0 6.4 0 6.9 6.1 10/10/2004 23:10:00 3 1.6 8.8 0.4 3.2 1.5 8.8 0.4 0.4 0 0.4 0.4 112 29 136 305 7 0 7 0 6.4 0 6.9 6.1 10/10/2004 23:20:00 3.7 1.3 6.8 0.4 3.7 1.3 6.8 0.7 0.4 0 0.4 0.4 111 27 143 305 7 0 7 0 6.3 0 6.7 6.1 10/10/2004 23:30:00 4.6 1.5 9.5 1.5 4.3 1.5 9.9 1.1 0.4 0 0.4 0.4 107 26 111 305 7 0 7 0 6.3 0 6.9 6.1 10/10/2004 23:40:00 3.9 1.2 7.2 0.4 3.8 1.3 7.6 0.7 0.4 0 0.4 0.4 105 26 95 305 7 0 7 0 6.3 0 6.9 6.1 10/10/2004 23:50:00 3.1 1.5 6.8 0.4 3.2 1.3 6.8 0.4 0.4 0 0.4 0.4 90 24 93 305 7 0 7 0 6.3 0 6.4 6.1 10/11/2004 00:00:00 3.7 1 7.2 1.1 3.5 1 6.1 1.1 0.4 0 0.4 0.4 97 22 107 305 7 0 7 0 6.3 0 6.7 6.1 10/11/2004 00:10:00 3.7 1.7 7.6 0.4 3.5 1.5 7.2 0.4 0.4 0 0.4 0.4 93 26 71 305 7 0 7 0 6.3 0 6.7 6.1 10/11/2004 00:20:00 5 1.6 9.9 1.5 4.8 1.6 9.9 1.9 0.4 0 0.4 0.4 74 26 92 305 7 0 7 0 6.5 0 6.9 6.1 10/11/2004 00:30:00 5.7 1.9 11.1 1.1 5.6 1.8 11.1 1.5 0.4 0 0.4 0.4 68 24 74 305 7 0 7 0 6.5 0 6.9 6.4 10/11/2004 00:40:00 6.8 1.3 10.3 3.4 6.7 1.4 11.5 3.4 0.4 0 0.4 0.4 63 12 67 305 7 0 7 0 6.5 0 6.9 6.1 10/11/2004 00:50:00 7 1.5 10.7 3 6.9 1.5 10.7 1.5 0.4 0 0.4 0.4 63 17 46 305 7 0 7 0 6.3 0 6.7 6.1 10/11/2004 01:00:00 6.4 1.6 11.8 3 6.2 1.7 11.1 2.6 0.4 0 0.4 0.4 68 20 70 305 6 0 6 0 6.3 0 6.9 6.1 10/11/2004 01:10:00 6.4 1.7 11.8 2.3 6.2 1.8 11.8 2.6 0.4 0 0.4 0.4 70 19 63 305 6 0 6 0 6.4 0 6.7 6.1 10/11/2004 01:20:00 7.5 1.7 11.5 3 7.4 2 11.5 2.6 0.4 0 0.4 0.4 72 18 48 305 6 0 6 0 6.3 0 6.7 6.1 10/11/2004 01:30:00 7.9 1.3 10.7 3 7.7 1.5 11.1 3 0.4 0 0.4 0.4 71 11 56 305 6 0 6 0 6.3 0 6.7 6.1 10/11/2004 01:40:00 8.3 1.1 11.5 4.9 8.3 1.1 11.8 5.3 0.4 0 0.4 0.4 73 9 55 305 5 0 5 0 6.3 0 6.7 6.1 10/11/2004 01:50:00 9 1.1 12.2 6.1 8.9 1 11.8 6.1 0.4 0 0.4 0.4 74 8 74 305 5 0 5 0 6.2 0.1 6.7 6.1 10/11/2004 02:00:00 9.4 1.2 13.3 6.5 9.1 1.3 13.7 6.1 0.4 0 0.4 0.4 75 10 64 305 5 0 5 0 6.1 0.1 6.4 5.9 10/11/2004 02:10:00 8.9 1.3 12.6 4.6 8.8 1.4 12.6 4.9 0.4 0 0.4 0.4 73 10 74 305 5 0 5 0 6.1 0.1 6.4 5.9 10/11/2004 02:20:00 8.4 1.5 13 4.9 8.2 1.6 12.2 4.2 0.4 0 0.4 0.4 75 15 70 305 5 0 5 0 6.3 0 6.7 6.1 10/11/2004 02:30:00 8.4 1.7 13 4.6 8.1 1.7 13.3 4.9 0.4 0 0.4 0.4 73 15 66 305 5 0 5 0 6.3 0 6.7 6.1 10/11/2004 02:40:00 7 2.1 12.6 2.3 6.7 2.3 12.6 1.1 0.4 0 0.4 0.4 76 22 63 305 5 0 5 0 6.3 0 6.7 6.1 10/11/2004 02:50:00 6.4 1.6 10.3 1.5 6.2 1.5 12.2 2.3 0.4 0 0.4 0.4 79 20 106 305 4 0 4 0 6.4 0 6.9 6.1 10/11/2004 03:00:00 6.4 1.5 11.1 2.6 6.4 1.5 10.7 2.6 0.4 0 0.4 0.4 74 20 63 305 4 0 4 0 6.5 0 6.9 6.4 10/11/2004 03:10:00 6.7 2 12.2 1.9 6.4 2 11.1 1.9 0.4 0 0.4 0.4 75 20 72 305 4 0 4 0 6.5 0 7.2 6.4 10/11/2004 03:20:00 6.4 1.7 13 3 6.2 1.9 11.5 2.6 0.4 0 0.4 0.4 73 19 65 305 4 0 4 0 6.5 0 7.2 6.4 10/11/2004 03:30:00 6.6 2 11.5 0.7 6.4 1.9 11.5 1.9 0.4 0 0.4 0.4 68 19 82 305 4 0 4 0 6.5 0 7.2 6.4 10/11/2004 03:40:00 6.4 1.6 10.7 2.6 6.2 1.5 10.7 2.6 0.4 0 0.4 0.4 69 15 92 305 4 0 4 0 6.5 0 6.9 6.1 10/11/2004 03:50:00 5.7 1.5 9.9 1.9 5.6 1.6 9.5 2.3 0.4 0 0.4 0.4 76 22 106 305 4 0 4 0 6.4 0 6.9 6.1 10/11/2004 04:00:00 4 1.4 8.4 0.7 3.7 1.3 8 1.1 0.4 0 0.4 0.4 91 30 60 305 4 0 4 0 6.4 0 6.7 6.1 10/11/2004 04:10:00 4.8 1.5 9.5 1.5 4.7 1.5 8.8 1.5 0.4 0 0.4 0.4 73 23 76 305 4 0 4 0 6.4 0 6.9 6.1 10/11/2004 04:20:00 4 1.2 6.1 0.4 3.7 1.1 6.1 0.7 0.4 0 0.4 0.4 79 21 76 305 4 0 4 0 6.3 0 6.7 6.1 10/11/2004 04:30:00 4.9 1.5 9.1 0.4 4.9 1.3 8 1.9 0.4 0 0.4 0.4 73 19 69 305 4 0 4 0 6.3 0 6.7 6.1 10/11/2004 04:40:00 5.6 1.3 8.8 2.6 5.7 1.3 8.4 3 0.4 0 0.4 0.4 64 17 60 305 4 0 4 0 6.3 0 6.9 6.1 10/11/2004 04:50:00 5.5 1.2 8.8 2.6 5.5 1.2 8.4 2.6 0.4 0 0.4 0.4 69 15 73 305 4 0 4 0 6.1 0.1 6.4 5.9 10/11/2004 05:00:00 5.2 1.3 8.4 1.5 5.2 1.2 8.8 1.9 0.4 0 0.4 0.4 68 20 64 305 4 0 4 0 6.1 0.1 6.4 5.9 10/11/2004 05:10:00 5.9 1.5 10.3 3 5.8 1.5 10.7 2.3 0.4 0 0.4 0.4 73 17 88 305 4 0 4 0 6.2 0.1 6.7 6.1 10/11/2004 05:20:00 6 1.1 9.1 3 5.8 1.1 8.8 3 0.4 0 0.4 0.4 78 13 80 305 4 0 4 0 6.1 0.1 6.4 5.9 10/11/2004 05:30:00 6.8 0.9 8.4 3.8 6.5 1 8.8 4.2 0.4 0 0.4 0.4 78 7 81 305 4 0 5 0 6 0.1 6.4 5.9 10/11/2004 05:40:00 7.5 0.8 10.3 5.3 7.3 0.9 9.5 4.9 0.4 0 0.4 0.4 77 6 83 305 5 0 5 0 6 0.1 6.4 5.9 10/11/2004 05:50:00 8 0.8 11.1 6.1 7.9 0.9 9.9 6.1 0.4 0 0.4 0.4 75 6 72 305 5 0 5 0 6 0 6.4 5.9 10/11/2004 06:00:00 7.9 0.9 11.1 5.3 7.7 1 10.3 4.9 0.4 0 0.4 0.4 76 7 74 305 5 0 5 0 5.8 0 6.1 5.6 10/11/2004 06:10:00 7.7 0.8 9.9 6.1 7.5 0.8 10.3 5.3 0.4 0 0.4 0.4 72 6 84 305 5 0 5 0 5.8 0 6.1 5.6 10/11/2004 06:20:00 8 0.7 9.9 6.1 7.8 0.8 10.7 5.7 0.4 0 0.4 0.4 70 6 71 305 5 0 5 0 5.7 0 6.1 5.6 10/11/2004 06:30:00 8.6 0.8 11.1 6.5 8.4 0.8 10.7 6.1 0.4 0 0.4 0.4 75 7 77 305 5 0 5 0 5.8 0 6.1 5.6 10/11/2004 06:40:00 8.4 0.8 10.7 6.1 8.2 0.9 10.7 5.7 0.4 0 0.4 0.4 78 6 70 305 6 0 6 0 5.8 0 6.4 5.9 10/11/2004 06:50:00 8.3 1 12.2 6.1 8 1.1 11.5 5.3 0.4 0 0.4 0.4 81 8 80 305 6 0 6 0 5.8 0 6.1 5.6 10/11/2004 07:00:00 8.2 1.3 11.8 4.6 7.9 1.2 10.7 4.9 0.4 0 0.4 0.4 84 9 68 305 6 0 6 0 5.9 0 6.4 5.9 10/11/2004 07:10:00 7.8 1.2 11.1 4.6 7.6 1.3 12.2 3.8 0.4 0 0.4 0.4 87 12 67 305 6 0 6 0 6 0 6.4 5.9 10/11/2004 07:20:00 7.7 1.1 10.3 4.6 7.4 1.2 10.3 4.6 0.4 0 0.4 0.4 87 11 81 305 6 0 6 0 6 0 6.4 5.9 10/11/2004 07:30:00 8.9 1 11.1 6.1 8.5 1 11.1 5.3 0.4 0 0.4 0.4 83 7 78 305 6 0 6 0 6 0 6.1 5.9 10/11/2004 07:40:00 9.4 0.9 12.6 6.8 9 1 11.5 6.1 0.4 0 0.4 0.4 79 6 76 305 6 0 6 0 5.8 0 6.1 5.6 10/11/2004 07:50:00 9.9 0.8 12.2 7.6 9.5 0.8 11.1 7.6 0.4 0 0.4 0.4 76 5 80 305 6 0 6 0 5.8 0 6.1 5.6 10/11/2004 08:00:00 9.9 0.6 11.5 8 9.5 0.7 11.1 6.8 0.4 0 0.4 0.4 72 5 69 305 6 0 6 0 5.7 0 6.1 5.6 10/11/2004 08:10:00 10.1 0.7 11.8 8 9.8 0.8 11.8 7.2 0.4 0 0.4 0.4 73 5 75 305 6 0 6 0 5.6 0 6.1 5.6 10/11/2004 08:20:00 10 0.7 12.2 7.2 9.7 0.8 11.5 6.8 0.4 0 0.4 0.4 75 5 73 305 6 0 6 0 5.6 0.1 6.1 5.6 10/11/2004 08:30:00 10.3 0.7 12.2 8.4 10 0.7 11.8 7.6 0.4 0 0.4 0.4 75 4 75 305 6 0 7 0 5.5 0.1 5.9 5.4 10/11/2004 08:40:00 10.6 0.7 12.6 8.8 10.2 0.8 12.6 7.6 0.4 0 0.4 0.4 73 5 77 305 7 0 7 0 5.6 0.1 5.9 5.6 10/11/2004 08:50:00 10.1 0.7 11.5 8 9.8 0.6 11.5 8 0.4 0 0.4 0.4 73 5 68 305 7 0 7 0 5.6 0.1 5.9 5.4 10/11/2004 09:00:00 10.6 0.5 11.8 9.5 10.2 0.6 11.8 7.6 0.4 0 0.4 0.4 71 4 77 305 7 0 7 0 5.6 0.1 5.9 5.4 10/11/2004 09:10:00 9.9 0.5 11.5 8.4 9.5 0.6 11.1 8 0.4 0 0.4 0.4 67 2 73 305 7 0 7 0 5.5 0 5.9 5.4 10/11/2004 09:20:00 9.1 0.5 10.3 7.2 8.6 0.6 9.9 7.2 0.4 0 0.4 0.4 65 3 70 305 7 0 7 0 5.4 0 5.9 5.4 10/11/2004 09:30:00 8.9 0.6 10.3 7.2 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 65 3 66 305 7 0 7 0 5.4 0 5.6 5.4 10/11/2004 09:40:00 9.6 0.6 11.1 8 9.1 0.7 10.7 6.8 0.4 0 0.4 0.4 64 3 65 305 7 0 7 0 5.4 0 5.9 5.2 10/11/2004 09:50:00 9.5 0.7 11.1 8 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 65 4 63 305 7 0 7 0 5.4 0 5.6 5.4 10/11/2004 10:00:00 9.5 0.6 10.7 8 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 65 3 72 305 7 0 7 0 5.4 0 5.9 5.4 10/11/2004 10:10:00 9.3 0.6 11.1 7.2 8.7 0.7 10.7 6.8 0.4 0 0.4 0.4 63 3 64 305 7 0 7 0 5.4 0 5.9 5.4 10/11/2004 10:20:00 9.6 0.6 11.1 8 9.1 0.6 10.7 7.6 0.4 0 0.4 0.4 63 3 64 305 7 0 7 0 5.5 0 5.9 5.4 10/11/2004 10:30:00 9.9 0.6 11.5 8.4 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 61 3 62 305 7 0 7 0 5.5 0 5.9 5.4 10/11/2004 10:40:00 10.7 0.8 12.6 8.8 10.2 1 12.2 7.6 0.4 0 0.4 0.4 64 4 64 305 7 0 7 0 5.5 0 5.9 5.4 10/11/2004 10:50:00 9.3 0.5 10.7 7.6 8.9 0.6 10.3 7.2 0.4 0 0.4 0.4 59 3 64 305 7 0 7 0 5.4 0 5.9 5.4 10/11/2004 11:00:00 9.4 0.5 10.7 8 9 0.6 10.3 7.6 0.4 0 0.4 0.4 58 2 55 305 7 0 7 0 5.3 0 5.6 5.2 10/11/2004 11:10:00 9.4 0.5 10.7 8 8.8 0.6 10.3 6.8 0.4 0 0.4 0.4 54 3 57 305 7 0 7 0 5.2 0 5.6 5.2 10/11/2004 11:20:00 9.7 0.5 11.1 8.4 9.2 0.5 10.7 7.6 0.4 0 0.4 0.4 55 3 57 305 7 0 7 0 5.2 0 5.6 5.2 10/11/2004 11:30:00 9.2 0.5 10.3 8 8.6 0.6 9.9 6.8 0.4 0 0.4 0.4 56 3 60 305 7 0 7 0 5.3 0 5.6 5.2 10/11/2004 11:40:00 9.2 0.5 10.7 7.6 8.6 0.6 10.3 7.2 0.4 0 0.4 0.4 55 3 55 305 7 0 7 0 5.3 0 5.6 5.2 10/11/2004 11:50:00 9.2 0.5 10.7 7.6 8.6 0.6 10.3 7.2 0.4 0 0.4 0.4 54 3 55 305 7 0 7 0 5.3 0 5.6 5.2 10/11/2004 12:00:00 9.2 0.5 10.7 8 8.7 0.5 10.3 7.2 0.4 0 0.4 0.4 53 3 60 305 7 0 7 0 5.2 0 5.6 5.2 10/11/2004 12:10:00 8.9 0.4 10.3 7.6 8.4 0.5 9.5 6.8 0.4 0 0.4 0.4 52 3 51 305 7 0 7 0 5.2 0 5.6 5.2 10/11/2004 12:20:00 8.8 0.4 9.9 7.6 8.4 0.5 9.5 6.8 0.4 0 0.4 0.4 56 3 61 305 7 0 7 0 5.3 0 5.6 5.2 10/11/2004 12:30:00 9 0.5 10.3 7.6 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 50 4 50 305 7 0 7 0 5.3 0 5.6 5.2 10/11/2004 12:40:00 9.3 0.4 10.3 7.6 8.7 0.5 9.9 7.2 0.4 0 0.4 0.4 44 3 48 305 7 0 7 0 5.2 0 5.6 5.2 10/11/2004 12:50:00 9.2 0.6 10.7 7.2 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 50 4 56 305 7 0 7 0 5.2 0 5.6 5.2 10/11/2004 13:00:00 8.8 0.5 9.9 6.8 8.2 0.6 9.5 6.5 0.4 0 0.4 0.4 53 3 56 305 7 0 7 0 5.2 0 5.6 5.2 10/11/2004 13:10:00 8.4 0.5 9.9 6.8 8 0.6 9.5 6.5 0.4 0 0.4 0.4 56 3 53 305 7 0 7 0 5.2 0 5.6 5.2 10/11/2004 13:20:00 8.4 0.4 9.5 7.2 8 0.5 9.5 6.8 0.4 0 0.4 0.4 55 3 55 305 7 0 7 0 5.2 0 5.6 5.2 10/11/2004 13:30:00 8.4 0.5 9.5 6.8 7.8 0.5 9.5 6.1 0.4 0 0.4 0.4 52 3 54 305 7 0 7 0 5.2 0 5.6 5.2 10/11/2004 13:40:00 9 0.7 10.3 6.5 8.4 0.7 9.9 6.5 0.4 0 0.4 0.4 48 4 47 305 7 0 7 0 5.2 0 5.6 4.9 10/11/2004 13:50:00 9 0.5 10.3 7.6 8.4 0.6 9.9 6.5 0.4 0 0.4 0.4 44 3 47 305 7 0 7 0 5.2 0 5.6 4.9 10/11/2004 14:00:00 9 0.5 9.9 7.6 8.4 0.5 9.5 6.8 0.4 0 0.4 0.4 41 3 41 305 7 0 7 0 5.1 0.1 5.4 4.9 10/11/2004 14:10:00 9 0.6 9.9 7.2 8.4 0.6 9.5 6.8 0.4 0 0.4 0.4 37 3 41 305 7 0 7 0 5 0.1 5.4 4.9 10/11/2004 14:20:00 8.4 0.6 9.9 6.5 7.9 0.6 9.1 6.5 0.4 0 0.4 0.4 35 3 39 305 7 0 7 0 4.9 0.1 5.4 4.9 10/11/2004 14:30:00 9.3 0.6 11.1 7.6 8.8 0.6 9.9 6.8 0.4 0 0.4 0.4 41 3 36 305 7 0 7 0 5 0.1 5.4 4.9 10/11/2004 14:40:00 9.6 0.6 11.1 8 9 0.6 10.3 7.6 0.4 0 0.4 0.4 37 3 40 305 7 0 7 0 4.9 0 5.4 4.7 10/11/2004 14:50:00 9.3 0.5 10.7 8 8.7 0.5 9.9 6.8 0.4 0 0.4 0.4 37 3 35 305 7 0 7 0 4.9 0.1 5.4 4.9 10/11/2004 15:00:00 9.4 0.5 10.7 8 8.7 0.5 9.9 7.2 0.4 0 0.4 0.4 42 3 44 305 7 0 7 0 5.1 0.1 5.6 4.9 10/11/2004 15:10:00 9.5 0.6 10.7 8 8.9 0.6 10.7 7.6 0.4 0 0.4 0.4 40 3 40 305 7 0 7 0 5.1 0.1 5.6 4.9 10/11/2004 15:20:00 10.6 0.9 12.6 8.4 9.9 1 12.2 8 0.4 0 0.4 0.4 40 3 44 305 7 0 7 0 5 0.1 5.4 4.7 10/11/2004 15:30:00 11.7 0.8 13.7 9.5 11 1 13.3 8.4 0.4 0 0.4 0.4 40 3 37 305 7 0 7 0 4.8 0 5.2 4.7 10/11/2004 15:40:00 12.2 0.9 14.9 9.5 11.6 1 13.7 9.1 0.4 0 0.4 0.4 40 4 30 305 7 0 7 0 4.7 0 4.9 4.4 10/11/2004 15:50:00 11.9 0.9 13.7 9.5 11.3 0.9 13.3 9.1 0.4 0 0.4 0.4 41 4 37 305 7 0 7 0 4.7 0 5.2 4.7 10/11/2004 16:00:00 12.3 0.9 14.5 9.9 11.7 0.9 13.3 9.1 0.4 0 0.4 0.4 39 3 35 305 7 0 7 0 4.7 0 5.2 4.7 10/11/2004 16:10:00 12 0.8 14.1 9.9 11.3 0.8 13.7 8.4 0.4 0 0.4 0.4 39 4 40 305 7 0 7 0 4.8 0 5.2 4.7 10/11/2004 16:20:00 12.7 0.9 14.9 9.9 12 1 14.1 9.1 0.4 0 0.4 0.4 39 4 44 305 7 0 7 0 4.7 0 5.2 4.7 10/11/2004 16:30:00 12.2 0.8 14.5 9.9 11.6 0.9 14.1 9.1 0.4 0 0.4 0.4 38 4 41 305 7 0 7 0 4.7 0 4.9 4.4 10/11/2004 16:40:00 12.1 1 14.9 9.5 11.4 1 13.7 8.8 0.4 0 0.4 0.4 39 4 40 305 7 0 7 0 4.6 0 4.9 4.4 10/11/2004 16:50:00 12.9 1 14.9 10.3 12.3 1 14.5 9.1 0.4 0 0.4 0.4 39 3 37 305 7 0 7 0 4.6 0.1 5.2 4.4 10/11/2004 17:00:00 12.9 1 15.3 10.7 12.2 1 14.9 9.1 0.4 0 0.4 0.4 39 4 39 305 7 0 7 0 4.5 0.1 4.9 4.4 10/11/2004 17:10:00 13.1 1 15.6 10.7 12.5 1.1 15.3 9.9 0.4 0 0.4 0.4 40 4 44 305 7 0 7 0 4.4 0.1 4.9 4.4 10/11/2004 17:20:00 12.8 0.9 15.3 10.3 12.1 1 14.5 9.1 0.4 0 0.4 0.4 38 4 37 305 7 0 7 0 4.4 0 4.9 4.4 10/11/2004 17:30:00 12.9 1 15.3 10.3 12.2 1 14.9 9.5 0.4 0 0.4 0.4 36 4 36 305 7 0 7 0 4.4 0 4.7 4.2 10/11/2004 17:40:00 13.2 1.1 15.3 10.3 12.6 1.1 14.9 9.9 0.4 0 0.4 0.4 37 3 39 305 7 0 7 0 4.3 0 4.7 4.2 10/11/2004 17:50:00 13.3 1 16.1 10.7 12.5 1 14.9 9.9 0.4 0 0.4 0.4 37 4 39 305 7 0 7 0 4.3 0 4.7 4.2 10/11/2004 18:00:00 13.4 1.1 16.1 10.3 12.7 1.2 15.6 9.5 0.4 0 0.4 0.4 37 4 39 305 7 0 7 0 4.2 0 4.7 4.2 10/11/2004 18:10:00 13.9 1.1 16.1 11.1 13.2 1.1 15.6 10.7 0.4 0 0.4 0.4 37 4 39 305 7 0 7 0 4.2 0.1 4.7 4.2 10/11/2004 18:20:00 13.8 1.1 16.1 10.7 13.2 1.1 15.6 9.9 0.4 0 0.4 0.4 38 4 36 305 7 0 7 0 4.2 0.1 4.7 4.2 10/11/2004 18:30:00 13.4 0.9 16.1 11.1 12.7 1 15.6 9.9 0.4 0 0.4 0.4 38 4 39 305 7 0 7 0 4.2 0 4.7 4.2 10/11/2004 18:40:00 13 1 15.6 10.3 12.4 1.1 14.9 9.5 0.4 0 0.4 0.4 36 4 29 305 7 0 7 0 4.2 0 4.7 4.2 10/11/2004 18:50:00 13.1 1 15.3 10.7 12.3 1 14.9 9.9 0.4 0 0.4 0.4 35 4 38 305 7 0 7 0 4.1 0 4.7 4.2 10/11/2004 19:00:00 13.7 1 16.4 11.1 13.1 1.1 15.6 9.9 0.4 0 0.4 0.4 36 4 31 305 7 0 7 0 4 0 4.4 4.2 10/11/2004 19:10:00 13.1 1.1 15.3 10.7 12.7 1.1 14.9 9.9 0.4 0 0.4 0.4 34 3 36 305 7 0 7 0 4.1 0 4.7 4.2 10/11/2004 19:20:00 13 1.1 15.3 9.9 12.4 1.1 15.3 9.1 0.4 0 0.4 0.4 35 4 32 305 7 0 7 0 4.1 0 4.7 4.2 10/11/2004 19:30:00 13.2 0.9 15.3 10.3 12.7 0.9 14.9 9.9 0.4 0 0.4 0.4 35 3 37 305 7 0 7 0 4.1 0 4.7 4.2 10/11/2004 19:40:00 13.2 1 15.3 9.9 12.6 1 14.9 9.9 0.4 0 0.4 0.4 35 3 35 305 7 0 7 0 4.2 0 4.7 4.2 10/11/2004 19:50:00 12.5 0.8 14.5 9.9 12 0.9 14.1 9.5 0.4 0 0.4 0.4 35 4 30 305 7 0 6 0 4.2 0 4.7 4.2 10/11/2004 20:00:00 11.8 1 14.5 9.5 11.2 1 14.1 8.8 0.4 0 0.4 0.4 35 3 37 305 7 0 6 0 4.3 0 4.7 4.2 10/11/2004 20:10:00 12.6 0.9 14.5 10.3 12 1 14.1 9.5 0.4 0 0.4 0.4 35 3 39 305 7 0 7 0 4.2 0 4.7 4.2 10/11/2004 20:20:00 11.8 0.9 14.5 9.5 11.3 1 13.7 9.1 0.4 0 0.4 0.4 34 4 37 305 7 0 7 0 4.2 0 4.7 4.2 10/11/2004 20:30:00 12 1 14.9 9.5 11.5 1.1 14.5 9.1 0.4 0 0.4 0.4 34 4 39 305 7 0 7 0 4.2 0 4.7 4.2 10/11/2004 20:40:00 12.3 1 14.1 9.9 11.8 1 13.7 9.5 0.4 0 0.4 0.4 32 5 39 305 6 0 6 0 4.1 0 4.7 3.9 10/11/2004 20:50:00 13.5 1.2 16.1 10.7 13 1 15.6 9.9 0.4 0 0.4 0.4 33 3 31 305 6 0 6 0 3.9 0.1 4.4 3.7 10/11/2004 21:00:00 14.2 1 16.4 11.8 13.6 1 16.1 11.1 0.4 0 0.4 0.4 35 4 37 305 6 0 6 0 3.9 0.1 4.4 3.7 10/11/2004 21:10:00 13.7 1.1 16.1 10.7 13.1 1.1 15.6 9.9 0.4 0 0.4 0.4 35 4 33 305 6 0 6 0 3.9 0.2 4.4 3.7 10/11/2004 21:20:00 12.9 1.1 16.1 10.3 12.4 1.2 15.6 9.9 0.4 0 0.4 0.4 34 4 29 305 6 0 6 0 3.9 0.2 4.4 3.7 10/11/2004 21:30:00 13.2 1.3 16.4 9.9 12.6 1.4 15.6 8.8 0.4 0 0.4 0.4 33 4 27 305 6 0 6 0 3.8 0.1 4.4 3.7 10/11/2004 21:40:00 14.2 0.9 16.4 11.5 13.6 1 16.1 10.7 0.4 0 0.4 0.4 31 4 28 305 6 0 6 0 3.7 0 4.2 3.4 10/11/2004 21:50:00 13.1 1.2 16.8 10.7 12.5 1.2 15.3 9.5 0.4 0 0.4 0.4 34 5 33 305 6 0 6 0 3.8 0.1 4.4 3.4 10/11/2004 22:00:00 13.7 1 15.6 10.7 13.2 1 15.3 9.5 0.4 0 0.4 0.4 34 3 36 305 6 0 6 0 3.7 0.1 4.4 3.7 10/11/2004 22:10:00 13.5 1.1 16.1 9.9 12.9 1.2 15.3 9.9 0.4 0 0.4 0.4 33 5 37 305 6 0 6 0 3.8 0 4.4 3.7 10/11/2004 22:20:00 13.5 1 15.6 10.7 13 1.1 15.6 9.9 0.4 0 0.4 0.4 32 4 32 305 6 0 6 0 3.7 0 4.2 3.4 10/11/2004 22:30:00 13.3 1 15.6 11.1 12.9 1 15.3 9.9 0.4 0 0.4 0.4 31 4 32 305 5 0 5 0 3.7 0 4.2 3.4 10/11/2004 22:40:00 13.6 1.3 16.4 10.3 13 1.3 15.3 9.5 0.4 0 0.4 0.4 32 5 37 305 5 0 5 0 3.6 0 4.2 3.4 10/11/2004 22:50:00 14.1 1.2 16.8 10.3 13.5 1.3 16.4 10.3 0.4 0 0.4 0.4 31 4 29 305 5 0 5 0 3.4 0.2 4.2 3.2 10/11/2004 23:00:00 14.2 1.1 16.4 11.5 13.7 1.1 16.1 10.7 0.4 0 0.4 0.4 30 3 31 305 5 0 5 0 3.4 0.1 3.9 3.2 10/11/2004 23:10:00 14.5 1 17.2 11.5 14 1 16.8 11.1 0.4 0 0.4 0.4 29 4 32 305 5 0 5 0 3.3 0 3.9 3.2 10/11/2004 23:20:00 14.6 0.9 16.8 11.8 14.1 0.9 16.8 11.8 0.4 0 0.4 0.4 25 4 24 305 5 0 5 0 3.3 0 3.7 3.2 10/11/2004 23:30:00 13.6 1 16.4 10.3 13.2 1.1 16.1 9.9 0.4 0 0.4 0.4 26 4 23 305 5 0 5 0 3.3 0 3.7 3.2 10/11/2004 23:40:00 14.2 1.1 16.4 11.1 13.7 1.1 16.1 10.7 0.4 0 0.4 0.4 26 4 27 305 5 0 5 0 3.3 0 3.7 3.2 10/11/2004 23:50:00 14.5 1.1 16.8 11.8 14 1.1 16.4 11.1 0.4 0 0.4 0.4 27 4 27 305 5 0 5 0 3.3 0 3.7 3.2 10/12/2004 00:00:00 14.4 1.2 17.2 11.1 14 1.3 17.2 11.1 0.4 0 0.4 0.4 24 4 27 305 5 0 5 0 3.3 0.1 3.7 3.2 10/12/2004 00:10:00 13.6 1.3 16.8 10.7 13.2 1.4 16.4 9.5 0.4 0 0.4 0.4 24 5 24 305 5 0 5 0 3.4 0.2 3.9 3.2 10/12/2004 00:20:00 14.5 1 16.4 11.8 14.1 1.1 16.4 11.1 0.4 0 0.4 0.4 22 5 19 305 5 0 5 0 3.2 0.1 3.7 2.9 10/12/2004 00:30:00 13.8 1.2 17.2 10.7 13.4 1.2 16.8 9.9 0.4 0 0.4 0.4 23 5 19 305 5 0 5 0 3 0.1 3.7 2.9 10/12/2004 00:40:00 14.3 1.4 17.2 10.3 13.9 1.5 16.4 10.3 0.4 0 0.4 0.4 26 4 29 305 5 0 5 0 3 0.1 3.4 2.9 10/12/2004 00:50:00 14.3 1.3 17.2 10.7 13.8 1.5 16.8 9.9 0.4 0 0.4 0.4 24 5 26 305 5 0 5 0 3 0.1 3.4 2.9 10/12/2004 01:00:00 14.8 1 17.2 11.8 14.2 1.1 16.8 11.1 0.4 0 0.4 0.4 25 4 26 305 5 0 5 0 3 0.1 3.4 2.7 10/12/2004 01:10:00 15.3 1.1 17.6 12.6 14.8 1.1 17.6 11.5 0.4 0 0.4 0.4 22 4 21 305 5 0 5 0 2.9 0.1 3.4 2.7 10/12/2004 01:20:00 15.4 1.1 17.9 12.6 15 1.1 17.2 11.1 0.4 0 0.4 0.4 22 3 20 305 5 0 5 0 2.8 0.2 3.4 2.7 10/12/2004 01:30:00 14.6 1.4 17.2 9.9 14.2 1.4 16.8 9.9 0.4 0 0.4 0.4 22 4 22 305 5 0 5 0 2.9 0.2 3.4 2.7 10/12/2004 01:40:00 14.8 1.4 18.3 10.7 14.3 1.4 17.6 11.1 0.4 0 0.4 0.4 26 5 22 305 5 0 5 0 2.8 0.2 3.4 2.7 10/12/2004 01:50:00 14.7 1.2 17.2 11.5 14.3 1.2 17.2 10.7 0.4 0 0.4 0.4 24 5 25 305 5 0 5 0 2.8 0.1 3.4 2.7 10/12/2004 02:00:00 15.1 1 17.6 11.8 14.7 1.1 17.2 11.8 0.4 0 0.4 0.4 23 5 19 305 5 0 5 0 2.8 0.1 3.4 2.5 10/12/2004 02:10:00 15.5 1.2 18.3 12.2 15 1.3 17.6 11.8 0.4 0 0.4 0.4 26 5 23 305 5 0 5 0 2.8 0.2 3.4 2.7 10/12/2004 02:20:00 15.1 1 17.6 12.2 14.5 1.1 16.4 10.7 0.4 0 0.4 0.4 28 5 21 305 5 0 5 0 2.9 0.2 3.4 2.7 10/12/2004 02:30:00 15.4 1 17.6 12.2 14.9 1.1 17.6 11.5 0.4 0 0.4 0.4 21 4 20 305 4 0 4 0 2.8 0.2 3.4 2.7 10/12/2004 02:40:00 15.7 1.2 18.7 12.6 15.4 1.2 18.7 12.2 0.4 0 0.4 0.4 22 4 25 305 4 0 4 0 2.8 0.2 3.4 2.5 10/12/2004 02:50:00 15.1 1.2 17.6 11.1 14.7 1.2 17.6 10.7 0.4 0 0.4 0.4 22 6 28 305 4 0 4 0 2.9 0.1 3.4 2.7 10/12/2004 03:00:00 15.5 1.1 18.7 12.6 15.2 1.2 18.7 11.8 0.4 0 0.4 0.4 16 4 16 305 4 0 4 0 2.8 0.2 3.4 2.5 10/12/2004 03:10:00 15.6 1.1 17.9 11.8 15.3 1.1 17.9 12.6 0.4 0 0.4 0.4 15 5 14 305 4 0 4 0 2.8 0.1 3.2 2.5 10/12/2004 03:20:00 15.8 1.1 18.7 12.6 15.5 1.2 18.7 12.2 0.4 0 0.4 0.4 14 4 18 305 4 0 4 0 2.7 0.1 3.2 2.5 10/12/2004 03:30:00 15.8 1.1 19.1 13 15.4 1.1 17.6 11.8 0.4 0 0.4 0.4 16 4 17 305 4 0 4 0 2.6 0 3.2 2.5 10/12/2004 03:40:00 15.6 1.1 17.9 12.6 15.3 1.2 17.9 11.5 0.4 0 0.4 0.4 17 4 13 305 4 0 4 0 2.6 0 3.2 2.5 10/12/2004 03:50:00 16.7 1.1 19.5 13 16.4 1.1 18.7 13.3 0.4 0 0.4 0.4 14 3 16 305 4 0 4 0 2.4 0 2.9 2.2 10/12/2004 04:00:00 16.3 1.2 18.7 13.3 15.9 1.2 18.7 12.2 0.4 0 0.4 0.4 13 3 12 305 4 0 4 0 2.5 0.1 2.9 2.2 10/12/2004 04:10:00 15.6 1 17.6 12.6 15.2 1 17.6 12.6 0.4 0 0.4 0.4 16 4 20 305 4 0 4 0 2.6 0 2.9 2.5 10/12/2004 04:20:00 15.1 1.4 17.9 10.7 14.8 1.5 17.9 9.9 0.4 0 0.4 0.4 16 4 14 305 4 0 5 0 2.5 0 3.2 2.5 10/12/2004 04:30:00 15.1 1.1 17.6 11.8 14.7 1 16.8 10.7 0.4 0 0.4 0.4 16 4 14 305 5 0 5 0 2.6 0 2.9 2.5 10/12/2004 04:40:00 15 1.2 17.9 11.5 14.6 1.2 17.6 11.5 0.4 0 0.4 0.4 16 4 10 305 5 0 5 0 2.6 0 3.2 2.5 10/12/2004 04:50:00 15.2 1.3 18.3 12.6 14.8 1.4 18.3 11.1 0.4 0 0.4 0.4 18 4 18 305 5 0 5 0 2.6 0 3.2 2.5 10/12/2004 05:00:00 15.4 1.2 17.9 11.8 15.1 1.3 17.6 11.1 0.4 0 0.4 0.4 16 4 18 305 5 0 5 0 2.6 0 2.9 2.5 10/12/2004 05:10:00 15.3 1.3 17.9 12.2 15 1.3 17.9 11.1 0.4 0 0.4 0.4 18 5 18 305 5 0 5 0 2.6 0 3.2 2.5 10/12/2004 05:20:00 15.2 1.3 17.9 11.8 14.7 1.3 18.3 11.8 0.4 0 0.4 0.4 23 5 30 305 5 0 5 0 2.7 0 3.2 2.5 10/12/2004 05:30:00 15.5 1.1 17.6 12.6 15 1.2 17.6 11.1 0.4 0 0.4 0.4 21 5 17 305 5 0 5 0 2.7 0 3.2 2.5 10/12/2004 05:40:00 15.8 1.1 18.3 12.2 15.5 1.3 18.3 11.5 0.4 0 0.4 0.4 14 4 12 305 5 0 5 0 2.6 0 2.9 2.5 10/12/2004 05:50:00 14.9 1.4 17.6 10.3 14.4 1.5 17.6 10.3 0.4 0 0.4 0.4 23 6 18 305 5 0 5 0 2.7 0 3.2 2.5 10/12/2004 06:00:00 14.8 1.2 17.6 11.5 14.2 1.2 17.2 10.3 0.4 0 0.4 0.4 25 4 20 305 5 0 5 0 2.7 0 3.2 2.5 10/12/2004 06:10:00 14.3 1 16.4 11.1 13.7 1.2 16.8 10.7 0.4 0 0.4 0.4 26 4 20 305 5 0 5 0 2.7 0 3.2 2.7 10/12/2004 06:20:00 14.9 0.9 17.2 12.2 14.5 1 17.2 11.1 0.4 0 0.4 0.4 23 6 28 305 5 0 5 0 2.7 0.1 3.2 2.5 10/12/2004 06:30:00 14.4 1.4 18.7 10.7 14 1.3 17.2 11.1 0.4 0 0.4 0.4 22 5 31 305 5 0 5 0 2.7 0 3.4 2.5 10/12/2004 06:40:00 15.3 1.3 17.9 12.2 14.8 1.3 18.3 11.8 0.4 0 0.4 0.4 23 5 16 305 4 0 5 0 2.7 0 3.2 2.5 10/12/2004 06:50:00 15.3 1 17.6 11.8 14.9 1 17.2 11.8 0.4 0 0.4 0.4 26 5 21 305 4 0 4 0 2.7 0 3.2 2.5 10/12/2004 07:00:00 14.8 1.2 17.6 11.8 14.5 1.3 17.2 11.5 0.4 0 0.4 0.4 16 6 13 305 4 0 4 0 2.7 0 3.2 2.5 10/12/2004 07:10:00 15.1 1.2 17.6 11.1 14.9 1.1 17.6 10.7 0.4 0 0.4 0.4 14 4 19 305 4 0 4 0 2.6 0 2.9 2.5 10/12/2004 07:20:00 14.3 1.1 16.8 11.5 14 1.1 16.1 11.1 0.4 0 0.4 0.4 19 6 24 305 4 0 4 0 2.6 0 3.2 2.5 10/12/2004 07:30:00 15.7 1.2 18.7 12.2 15.4 1.2 17.9 12.2 0.4 0 0.4 0.4 21 5 25 305 4 0 4 0 2.5 0 2.9 2.5 10/12/2004 07:40:00 14.9 1 17.6 12.6 14.7 1 17.2 11.8 0.4 0 0.4 0.4 18 3 14 305 4 0 4 0 2.5 0 2.9 2.2 10/12/2004 07:50:00 14.5 1.1 16.8 10.7 14.3 1.2 16.8 10.3 0.4 0 0.4 0.4 18 5 13 305 4 0 4 0 2.6 0 2.9 2.5 10/12/2004 08:00:00 15.1 1.3 17.9 11.1 14.8 1.3 17.2 10.3 0.4 0 0.4 0.4 11 4 5 305 4 0 4 0 2.5 0 2.7 2.2 10/12/2004 08:10:00 15 1.1 17.9 11.5 14.7 1.1 17.6 12.2 0.4 0 0.4 0.4 15 4 12 305 4 0 4 0 2.6 0 3.2 2.5 10/12/2004 08:20:00 15.2 1.1 17.2 11.5 14.9 1.2 17.6 11.1 0.4 0 0.4 0.4 13 3 11 305 4 0 4 0 2.6 0 3.2 2.5 10/12/2004 08:30:00 14.9 1.1 17.2 12.2 14.6 1.2 17.9 10.7 0.4 0 0.4 0.4 16 5 16 305 4 0 4 0 2.6 0 2.9 2.2 10/12/2004 08:40:00 15.1 1.3 18.7 10.7 14.9 1.3 18.3 10.7 0.4 0 0.4 0.4 17 5 11 305 4 0 4 0 2.6 0 3.2 2.2 10/12/2004 08:50:00 14.9 1.1 17.6 12.2 14.4 1.3 17.6 11.5 0.4 0 0.4 0.4 24 5 24 305 4 0 4 0 2.6 0 3.2 2.5 10/12/2004 09:00:00 14.5 1.1 17.2 11.1 14.4 1 17.2 10.7 0.4 0 0.4 0.4 15 4 13 305 4 0 4 0 2.6 0 3.2 2.5 10/12/2004 09:10:00 14.5 1.1 17.2 11.8 14.3 1.1 17.2 11.5 0.4 0 0.4 0.4 16 4 14 305 4 0 4 0 2.7 0 3.2 2.5 10/12/2004 09:20:00 14.5 1.4 18.3 11.5 14.3 1.5 17.9 11.1 0.4 0 0.4 0.4 20 5 13 305 4 0 4 0 2.8 0.1 3.4 2.7 10/12/2004 09:30:00 14.9 1.3 18.7 11.5 14.5 1.3 17.6 10.7 0.4 0 0.4 0.4 20 5 27 305 4 0 4 0 2.8 0.1 3.2 2.7 10/12/2004 09:40:00 14.6 1.1 17.2 11.1 14 1.1 17.2 11.1 0.4 0 0.4 0.4 23 6 19 305 4 0 4 0 2.9 0.1 3.2 2.7 10/12/2004 09:50:00 14.7 1.1 17.6 11.1 14.3 1.2 17.2 10.3 0.4 0 0.4 0.4 21 5 14 305 4 0 4 0 2.8 0.1 3.2 2.7 10/12/2004 10:00:00 14.8 1.3 17.6 11.1 14.3 1.4 17.2 10.3 0.4 0 0.4 0.4 22 5 12 305 4 0 4 0 2.9 0.1 3.4 2.7 10/12/2004 10:10:00 15.2 1.1 17.6 12.6 14.9 1.1 17.6 11.8 0.4 0 0.4 0.4 20 6 11 305 3 0 4 0 2.9 0 3.4 2.7 10/12/2004 10:20:00 15.4 1.2 17.9 11.8 15.1 1.2 17.6 11.5 0.4 0 0.4 0.4 19 4 20 305 3 0 3 0 2.9 0 3.4 2.9 10/12/2004 10:30:00 14.9 1 17.2 11.1 14.7 1.1 17.2 11.5 0.4 0 0.4 0.4 15 4 15 305 3 0 3 0 2.9 0 3.4 2.9 10/12/2004 10:40:00 14.5 1.1 16.8 11.1 14.1 1.1 16.8 11.1 0.4 0 0.4 0.4 24 6 18 305 3 0 3 0 2.9 0.1 3.4 2.9 10/12/2004 10:50:00 15 0.9 17.9 12.2 14.5 1 16.8 11.1 0.4 0 0.4 0.4 23 6 18 305 3 0 3 0 2.9 0.1 3.4 2.7 10/12/2004 11:00:00 14.8 1.1 17.6 11.5 14.5 1.1 17.2 11.5 0.4 0 0.4 0.4 22 6 11 305 3 0 2 0 2.9 0.1 3.2 2.7 10/12/2004 11:10:00 14.6 1.2 17.6 11.5 14.4 1.3 17.6 10.7 0.4 0 0.4 0.4 22 6 18 305 2 0 2 0 2.8 0.1 3.2 2.7 10/12/2004 11:20:00 15.1 1.1 17.6 12.2 14.6 1.2 17.2 11.1 0.4 0 0.4 0.4 24 5 21 305 2 0 2 0 2.8 0 3.2 2.7 10/12/2004 11:30:00 14.6 1 17.6 11.8 14.3 1.1 17.6 11.1 0.4 0 0.4 0.4 21 5 13 305 2 0 2 0 2.8 0.1 3.2 2.7 10/12/2004 11:40:00 14.7 1.3 17.6 11.1 14.2 1.5 17.6 9.9 0.4 0 0.4 0.4 23 5 22 305 2 0 2 0 2.8 0 3.2 2.7 10/12/2004 11:50:00 14.5 1 17.2 11.1 14 1.2 16.4 9.9 0.4 0 0.4 0.4 28 4 27 305 2 0 2 0 2.8 0.1 3.2 2.7 10/12/2004 12:00:00 13.8 0.9 15.6 11.8 13.2 0.9 15.3 10.7 0.4 0 0.4 0.4 33 4 32 305 2 0 2 0 2.8 0.1 3.4 2.7 10/12/2004 12:10:00 14.3 1 16.4 10.3 13.9 1.2 16.1 9.5 0.4 0 0.4 0.4 23 5 21 305 2 0 2 0 2.8 0.1 3.2 2.5 10/12/2004 12:20:00 14 1 16.1 10.7 13.8 1.1 16.1 10.3 0.4 0 0.4 0.4 22 5 25 305 2 0 2 0 2.7 0 3.2 2.5 10/12/2004 12:30:00 14.6 0.8 16.4 12.2 14.2 1 16.4 11.8 0.4 0 0.4 0.4 25 6 23 305 2 0 2 0 2.7 0 3.2 2.5 10/12/2004 12:40:00 13.9 1.3 17.2 10.3 13.4 1.4 16.8 9.9 0.4 0 0.4 0.4 28 4 33 305 2 0 2 0 2.8 0 3.2 2.5 10/12/2004 12:50:00 14.1 1.2 16.8 11.1 13.9 1.2 16.8 10.7 0.4 0 0.4 0.4 22 5 22 305 2 0 2 0 2.8 0.1 3.2 2.5 10/12/2004 13:00:00 14.1 1.1 16.4 10.3 13.6 1.2 16.4 10.3 0.4 0 0.4 0.4 27 5 26 305 1 0 1 0 2.8 0.1 3.2 2.7 10/12/2004 13:10:00 14 1.2 17.2 10.3 13.7 1.3 16.8 10.3 0.4 0 0.4 0.4 21 4 19 305 1 0 1 0 2.9 0.1 3.4 2.7 10/12/2004 13:20:00 13.4 1.1 16.4 10.7 13.1 1.2 16.4 9.1 0.4 0 0.4 0.4 24 6 27 305 2 0 2 0 3 0 3.4 2.9 10/12/2004 13:30:00 14.3 1.1 16.8 11.5 13.8 1.1 16.4 9.9 0.4 0 0.4 0.4 30 5 31 305 2 0 1 0 2.9 0.1 3.2 2.7 10/12/2004 13:40:00 14.6 1.2 17.2 11.1 14.1 1.3 17.2 11.1 0.4 0 0.4 0.4 26 5 24 305 1 0 1 0 3 0 3.4 2.7 10/12/2004 13:50:00 15.5 1.2 17.9 11.1 14.9 1.3 17.6 10.7 0.4 0 0.4 0.4 28 5 30 305 1 0 1 0 3 0 3.4 2.9 10/12/2004 14:00:00 15.4 1.2 17.6 10.7 14.7 1.2 17.2 11.5 0.4 0 0.4 0.4 30 4 24 305 1 0 1 0 3 0.1 3.4 2.9 10/12/2004 14:10:00 15.1 1.1 17.6 12.6 14.5 1.1 17.2 11.5 0.4 0 0.4 0.4 30 5 32 305 1 0 1 0 3 0 3.4 2.9 10/12/2004 14:20:00 15.6 1 17.6 12.6 15.2 1.1 17.6 12.2 0.4 0 0.4 0.4 20 4 17 305 1 0 1 0 2.9 0.1 3.4 2.7 10/12/2004 14:30:00 14.9 1 17.2 11.5 14.6 1.2 16.8 11.1 0.4 0 0.4 0.4 22 4 20 305 1 0 1 0 3 0 3.4 2.9 10/12/2004 14:40:00 13.5 1.1 16.4 9.9 13 1.1 15.6 9.5 0.4 0 0.4 0.4 27 5 27 305 1 0 1 0 3.1 0 3.7 2.9 10/12/2004 14:50:00 14.8 1.1 17.9 11.8 14.2 1.1 16.8 10.7 0.4 0 0.4 0.4 31 7 40 305 1 0 1 0 3.1 0 3.4 2.9 10/12/2004 15:00:00 15.2 1.1 17.9 12.2 14.8 1.1 17.2 12.2 0.4 0 0.4 0.4 23 5 27 305 1 0 1 0 3.1 0.1 3.7 2.9 10/12/2004 15:10:00 15.6 1 17.6 12.6 15.2 1.1 17.9 12.2 0.4 0 0.4 0.4 22 4 19 305 1 0 1 0 3 0.1 3.4 2.9 10/12/2004 15:20:00 14.8 1 17.6 12.2 14.4 1.1 17.6 11.5 0.4 0 0.4 0.4 24 4 25 305 1 0 1 0 3.1 0 3.7 2.9 10/12/2004 15:30:00 14.1 1.1 17.6 9.9 13.9 1.2 16.8 9.9 0.4 0 0.4 0.4 22 4 21 305 1 0 1 0 3.1 0.1 3.7 2.9 10/12/2004 15:40:00 15.2 1.3 17.9 10.7 14.9 1.3 17.6 10.7 0.4 0 0.4 0.4 20 4 17 305 1 0 1 0 3.1 0.1 3.7 2.9 10/12/2004 15:50:00 15.2 1 17.2 11.8 14.7 1.1 17.2 11.5 0.4 0 0.4 0.4 23 5 22 305 1 0 1 0 3 0.1 3.4 2.9 10/12/2004 16:00:00 15.6 1.3 18.3 12.2 15.1 1.3 18.3 11.8 0.4 0 0.4 0.4 21 5 19 305 1 0 1 0 3.1 0.1 3.7 2.9 10/12/2004 16:10:00 15.5 1.3 18.3 11.1 15 1.5 17.6 9.9 0.4 0 0.4 0.4 20 5 22 305 1 0 1 0 2.9 0.1 3.7 2.7 10/12/2004 16:20:00 15 1.2 17.6 11.5 14.6 1.3 17.2 10.3 0.4 0 0.4 0.4 22 5 15 305 1 0 1 0 3 0.1 3.7 2.7 10/12/2004 16:30:00 14.5 1.1 17.6 11.5 14.1 1.2 17.6 11.5 0.4 0 0.4 0.4 22 5 18 305 1 0 1 0 2.9 0.1 3.4 2.9 10/12/2004 16:40:00 15 1 17.2 12.2 14.7 1.1 17.2 11.8 0.4 0 0.4 0.4 20 4 20 305 1 0 1 0 2.8 0.1 3.4 2.5 10/12/2004 16:50:00 14.7 1.2 17.2 10.3 14.5 1.2 17.6 10.7 0.4 0 0.4 0.4 18 5 17 305 1 0 1 0 2.8 0.1 3.4 2.7 10/12/2004 17:00:00 15.3 1.1 17.6 12.6 15.1 1.1 17.6 11.8 0.4 0 0.4 0.4 19 4 21 305 1 0 1 0 2.8 0.1 3.2 2.5 10/12/2004 17:10:00 15 1.2 17.6 11.8 14.6 1.2 17.2 11.5 0.4 0 0.4 0.4 21 5 17 305 1 0 1 0 2.9 0.2 3.2 2.7 10/12/2004 17:20:00 14.3 1 16.4 11.1 14 1 16.4 11.5 0.4 0 0.4 0.4 15 4 13 305 1 0 1 0 2.8 0.1 3.4 2.5 10/12/2004 17:30:00 14 1.2 16.8 11.1 13.8 1.3 16.4 10.3 0.4 0 0.4 0.4 15 5 4 305 1 0 1 0 2.6 0 3.2 2.5 10/12/2004 17:40:00 14.3 1 16.4 11.5 14.1 1.1 16.4 11.1 0.4 0 0.4 0.4 14 4 12 305 1 0 1 0 2.6 0 3.2 2.2 10/12/2004 17:50:00 14.8 1 17.2 11.8 14.8 1 17.2 11.8 0.4 0 0.4 0.4 14 4 14 305 1 0 1 0 2.2 0.1 2.9 2 10/12/2004 18:00:00 15 1.2 17.6 11.8 14.8 1.2 17.9 11.5 0.4 0 0.4 0.4 13 5 12 305 1 0 1 0 2.2 0 2.7 2 10/12/2004 18:10:00 15 1.1 17.6 12.2 15 1.2 17.9 11.8 0.4 0 0.4 0.4 13 4 13 305 1 0 1 0 1.9 0 2.5 1.5 10/12/2004 18:20:00 15.1 1.3 17.6 10.7 15 1.3 17.6 11.1 0.4 0 0.4 0.4 10 4 14 305 1 0 1 0 1.8 0 2.2 1.5 10/12/2004 18:30:00 15.4 1.1 17.6 11.5 15.3 1.2 17.9 11.8 0.4 0 0.4 0.4 12 4 8 305 1 0 1 0 1.8 0 2.2 1.5 10/12/2004 18:40:00 15 1 17.2 13 14.8 1.1 17.9 12.2 0.4 0 0.4 0.4 13 4 17 305 1 0 1 0 1.9 0 2.5 1.5 10/12/2004 18:50:00 14.7 1.1 16.8 11.1 14.6 1.1 17.2 11.8 0.4 0 0.4 0.4 16 4 14 305 1 0 1 0 1.9 0 2.5 1.5 10/12/2004 19:00:00 14.9 1 17.9 12.2 14.6 1 17.2 11.8 0.4 0 0.4 0.4 16 5 14 305 1 0 1 0 1.7 0.1 2.2 1.5 10/12/2004 19:10:00 14.4 1.1 17.2 11.1 14 1.1 16.8 11.1 0.4 0 0.4 0.4 24 4 21 305 1 0 1 0 1.7 0.1 2.2 1.5 10/12/2004 19:20:00 14.9 0.8 17.2 12.2 14.7 0.9 17.2 12.2 0.4 0 0.4 0.4 19 4 17 305 1 0 1 0 1.7 0.1 2.2 1.5 10/12/2004 19:30:00 14.3 1 17.2 11.8 14.1 1.1 17.2 11.1 0.4 0 0.4 0.4 20 5 17 305 1 0 1 0 1.7 0.1 2.2 1.5 10/12/2004 19:40:00 14.2 1 16.4 11.5 13.9 1.1 16.1 10.3 0.4 0 0.4 0.4 25 5 31 305 1 0 1 0 1.8 0.1 2.5 1.5 10/12/2004 19:50:00 13.9 1 16.1 10.3 13.4 1.1 15.6 10.3 0.4 0 0.4 0.4 30 5 41 305 1 0 1 0 1.7 0.1 2.2 1.5 10/12/2004 20:00:00 14 1 16.4 11.5 13.6 1 15.6 11.1 0.4 0 0.4 0.4 31 4 28 305 1 0 1 0 1.9 0 2.2 1.7 10/12/2004 20:10:00 13.6 1 15.6 11.1 13.2 1 15.3 10.3 0.4 0 0.4 0.4 31 5 32 305 1 0 1 0 1.9 0 2.2 1.7 10/12/2004 20:20:00 14 1 16.1 10.7 13.5 1 15.3 9.5 0.4 0 0.4 0.4 31 4 29 305 1 0 1 0 1.9 0 2.2 1.7 10/12/2004 20:30:00 12.7 1 15.6 10.3 12.3 1 14.9 9.9 0.4 0 0.4 0.4 31 5 32 305 1 0 1 0 1.9 0 2.2 1.7 10/12/2004 20:40:00 13.2 0.7 14.9 11.1 12.9 0.8 14.9 10.7 0.4 0 0.4 0.4 28 4 28 305 1 0 1 0 1.9 0 2.2 1.7 10/12/2004 20:50:00 12.4 0.8 14.1 9.1 12.1 1 14.5 9.1 0.4 0 0.4 0.4 29 5 27 305 1 0 1 0 1.8 0.1 2.2 1.5 10/12/2004 21:00:00 13.1 0.9 15.3 10.3 12.8 1 14.9 9.9 0.4 0 0.4 0.4 27 5 18 305 1 0 0 0 1.9 0 2.5 1.7 10/12/2004 21:10:00 12.2 0.8 14.1 9.9 11.8 0.9 14.1 9.5 0.4 0 0.4 0.4 26 5 24 305 1 0 1 0 2.2 0.1 2.7 2 10/12/2004 21:20:00 12.6 0.7 14.9 10.3 12.2 0.8 14.5 9.9 0.4 0 0.4 0.4 29 4 29 305 1 0 1 0 2.2 0 2.5 2 10/12/2004 21:30:00 12.3 1 14.5 9.1 12 1.1 14.1 9.1 0.4 0 0.4 0.4 25 4 30 305 0 0 0 0 2.3 0.1 2.7 2.2 10/12/2004 21:40:00 12.8 0.9 14.5 10.3 12.7 0.9 14.5 10.3 0.4 0 0.4 0.4 21 5 25 305 0 0 0 0 2.2 0.1 2.7 2.2 10/12/2004 21:50:00 12 0.9 13.7 9.1 12 1 14.1 9.5 0.4 0 0.4 0.4 13 5 19 305 0 0 0 0 2.3 0.1 2.7 2.2 10/12/2004 22:00:00 11.8 0.9 14.1 8.8 11.9 1 14.5 9.1 0.4 0 0.4 0.4 13 4 10 305 0 0 0 0 2.3 0.1 2.7 2.2 10/12/2004 22:10:00 12.2 0.9 14.1 9.5 12.3 1 14.1 8.8 0.4 0 0.4 0.4 9 4 1 305 0 0 0 0 2.2 0 2.7 2.2 10/12/2004 22:20:00 12.2 1 14.5 9.5 12.2 1.1 14.9 9.5 0.4 0 0.4 0.4 8 4 4 305 0 0 0 0 2.2 0 2.7 2 10/12/2004 22:30:00 12.1 0.8 14.5 9.9 12.1 0.9 14.1 9.5 0.4 0 0.4 0.4 9 4 8 305 0 0 0 0 2.2 0 2.7 2 10/12/2004 22:40:00 12.2 0.9 14.5 9.5 12.3 1 14.5 9.5 0.4 0 0.4 0.4 8 5 5 305 0 0 0 0 2.3 0.1 2.7 2.2 10/12/2004 22:50:00 12.1 0.9 14.1 8.8 12.2 1 14.1 8.8 0.4 0 0.4 0.4 10 5 7 305 0 0 0 0 2.3 0 2.7 2.2 10/12/2004 23:00:00 12.6 0.7 14.5 10.7 12.7 0.8 14.9 10.7 0.4 0 0.4 0.4 9 3 10 305 0 0 0 0 2.3 0 2.7 2.2 10/12/2004 23:10:00 12.8 0.8 14.9 10.7 12.9 0.9 14.5 10.3 0.4 0 0.4 0.4 9 4 8 305 0 0 0 0 2.3 0.1 2.7 2.2 10/12/2004 23:20:00 12.5 0.8 14.5 10.3 12.4 1 14.9 9.9 0.4 0 0.4 0.4 9 4 7 305 0 0 0 0 2.3 0.1 2.7 2.2 10/12/2004 23:30:00 12.5 0.8 14.5 10.3 12.5 0.9 14.5 9.9 0.4 0 0.4 0.4 6 5 4 305 0 0 0 0 2.2 0 2.7 2.2 10/12/2004 23:40:00 12.7 0.7 14.5 10.3 12.8 0.8 14.9 10.3 0.4 0 0.4 0.4 9 3 10 305 0 0 0 0 2.2 0 2.5 2 10/12/2004 23:50:00 12.5 1.1 14.9 9.5 12.6 1.1 15.3 9.5 0.4 0 0.4 0.4 9 4 13 305 0 0 0 0 2.2 0 2.5 2 10/13/2004 00:00:00 12.6 0.7 14.1 9.9 12.7 0.8 14.5 9.9 0.4 0 0.4 0.4 7 6 15 305 0 0 0 0 2 0 2.5 2 10/13/2004 00:10:00 12.9 0.8 14.9 10.3 13 0.8 14.9 9.9 0.4 0 0.4 0.4 5 4 5 305 0 0 0 0 1.9 0 2.2 1.7 10/13/2004 00:20:00 12.4 0.8 14.5 9.9 12.6 0.8 14.5 9.9 0.4 0 0.4 0.4 5 4 8 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 00:30:00 12.1 0.8 14.1 9.1 12.3 0.9 14.1 9.5 0.4 0 0.4 0.4 1 4 0 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 00:40:00 11.1 0.8 12.6 8.8 11.2 0.9 13 8.8 0.4 0 0.4 0.4 1 5 1 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 00:50:00 11.6 0.8 13 8.8 11.8 0.9 13.7 8.4 0.4 0 0.4 0.4 1 3 2 305 0 0 0 0 1.7 0 2.2 1.5 10/13/2004 01:00:00 11.6 0.8 13.7 8.8 11.8 0.8 14.1 8.4 0.4 0 0.4 0.4 1 4 3 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 01:10:00 11.4 0.9 13.3 9.1 11.6 0.9 13.7 9.1 0.4 0 0.4 0.4 1 4 359 305 0 0 0 0 1.7 0 2.2 1.5 10/13/2004 01:20:00 11.5 0.8 13.7 9.5 11.7 0.8 13.7 9.1 0.4 0 0.4 0.4 5 5 1 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 01:30:00 11.5 0.8 13.3 9.1 11.7 0.8 13.3 9.9 0.4 0 0.4 0.4 7 3 3 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 01:40:00 11.1 0.8 13.3 9.1 11.2 0.9 13 9.1 0.4 0 0.4 0.4 7 4 8 305 0 0 0 0 1.7 0 2.2 1.5 10/13/2004 01:50:00 11.2 0.9 13 8.8 11.3 0.9 13.3 8.8 0.4 0 0.4 0.4 5 4 0 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 02:00:00 11.3 0.8 13.3 8.8 11.4 0.9 13.3 8.4 0.4 0 0.4 0.4 7 4 7 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 02:10:00 11.2 1 13.3 8 11.4 1 13.3 8 0.4 0 0.4 0.4 5 5 5 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 02:20:00 11.3 0.8 13 9.1 11.5 0.8 13.3 8.4 0.4 0 0.4 0.4 6 6 8 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 02:30:00 11.1 0.8 13 8.8 11.3 0.9 14.1 9.1 0.4 0 0.4 0.4 1 5 357 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 02:40:00 11.5 0.6 13.3 9.9 11.7 0.7 13.7 9.9 0.4 0 0.4 0.4 3 4 0 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 02:50:00 11.2 0.7 13 8.8 11.3 0.8 13 9.1 0.4 0 0.4 0.4 6 4 1 305 0 0 0 0 1.5 0 2 1.3 10/13/2004 03:00:00 10.7 0.7 12.2 8.8 10.8 0.7 12.6 8.8 0.4 0 0.4 0.4 11 3 13 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 03:10:00 10.5 0.7 12.2 8 10.6 0.8 12.2 8 0.4 0 0.4 0.4 8 4 8 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 03:20:00 10.6 0.7 12.2 8.4 10.8 0.8 13 8.8 0.4 0 0.4 0.4 4 4 7 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 03:30:00 10.1 0.7 11.8 8 10.4 0.7 12.6 8.4 0.4 0 0.4 0.4 4 4 1 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 03:40:00 10 0.7 11.5 8 10.2 0.8 12.2 8.4 0.4 0 0.4 0.4 5 5 359 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 03:50:00 10.6 0.6 11.8 8 10.8 0.7 12.6 8 0.4 0 0.4 0.4 5 4 4 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 04:00:00 10.1 0.7 11.5 8.4 10.4 0.7 11.8 7.6 0.4 0 0.4 0.4 3 4 7 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 04:10:00 9.8 0.7 11.5 8 10 0.8 11.8 7.6 0.4 0 0.4 0.4 4 4 4 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 04:20:00 9.8 0.9 11.8 6.8 10 1 12.2 7.2 0.4 0 0.4 0.4 2 4 359 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 04:30:00 10 0.6 11.5 8.4 10.1 0.7 12.6 7.6 0.4 0 0.4 0.4 3 4 3 305 0 0 0 0 1.5 0 2 1.3 10/13/2004 04:40:00 10 0.8 11.8 7.6 10.2 0.8 12.2 7.6 0.4 0 0.4 0.4 1 3 2 305 0 0 0 0 1.5 0 2.2 1.3 10/13/2004 04:50:00 10.2 0.7 11.8 8.4 10.5 0.8 12.2 8.4 0.4 0 0.4 0.4 0 4 0 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 05:00:00 10.3 0.6 11.8 8.8 10.4 0.7 11.8 8 0.4 0 0.4 0.4 3 4 357 305 0 0 0 0 1.4 0 1.7 1.3 10/13/2004 05:10:00 10.1 0.6 11.5 8.4 10.3 0.6 11.8 8.4 0.4 0 0.4 0.4 4 4 1 305 0 0 0 0 1.4 0 1.7 1.3 10/13/2004 05:20:00 10.3 0.5 11.5 8.4 10.5 0.6 12.2 8.4 0.4 0 0.4 0.4 0 3 359 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 05:30:00 9.9 0.5 11.1 8.4 10.1 0.6 11.8 8.8 0.4 0 0.4 0.4 359 4 7 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 05:40:00 9.8 0.7 11.1 8 10.1 0.7 11.5 8.4 0.4 0 0.4 0.4 359 3 357 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 05:50:00 9.4 0.7 11.1 7.6 9.6 0.6 11.5 8 0.4 0 0.4 0.4 2 4 5 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 06:00:00 9 0.5 10.3 7.2 9.2 0.5 10.7 7.6 0.4 0 0.4 0.4 5 3 11 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 06:10:00 9 0.5 9.9 7.2 9.2 0.6 10.3 7.2 0.4 0 0.4 0.4 11 4 8 305 0 0 0 0 1.5 0 2 1.3 10/13/2004 06:20:00 8.6 0.5 9.9 7.2 8.7 0.6 10.3 7.2 0.4 0 0.4 0.4 8 5 2 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 06:30:00 8.6 0.4 9.5 6.8 8.7 0.5 9.9 7.2 0.4 0 0.4 0.4 10 4 10 305 0 0 0 0 1.5 0 2 1.5 10/13/2004 06:40:00 8.4 0.5 9.5 6.5 8.6 0.6 9.9 6.5 0.4 0 0.4 0.4 6 4 7 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 06:50:00 8.7 0.5 9.9 7.6 8.8 0.5 10.3 7.6 0.4 0 0.4 0.4 12 4 29 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 07:00:00 8.8 0.5 9.9 7.6 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 19 5 18 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 07:10:00 8.2 0.4 9.1 6.8 8.2 0.5 9.5 6.5 0.4 0 0.4 0.4 19 4 14 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 07:20:00 8 0.4 8.8 6.8 8 0.4 9.1 6.8 0.4 0 0.4 0.4 20 3 25 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 07:30:00 7.7 0.4 8.8 6.5 7.7 0.5 8.8 6.1 0.4 0 0.4 0.4 19 3 17 305 0 0 0 0 1.6 0.1 2.2 1.5 10/13/2004 07:40:00 7.4 0.4 8.4 6.1 7.4 0.5 8.4 6.1 0.4 0 0.4 0.4 20 4 21 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 07:50:00 7.3 0.4 8 6.1 7.3 0.4 8 6.1 0.4 0 0.4 0.4 19 3 19 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 08:00:00 7.2 0.4 8 6.1 7.2 0.4 8.4 5.7 0.4 0 0.4 0.4 22 5 24 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 08:10:00 6.7 0.4 7.6 5.3 6.8 0.4 7.6 5.7 0.4 0 0.4 0.4 17 5 19 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 08:20:00 6.5 0.4 7.2 5.3 6.6 0.4 7.6 5.7 0.4 0 0.4 0.4 16 4 23 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 08:30:00 6.8 0.6 8.4 5.3 7 0.7 8.8 5.7 0.4 0 0.4 0.4 6 5 357 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 08:40:00 7.2 0.4 8 5.7 7.5 0.4 8.8 6.5 0.4 0 0.4 0.4 6 4 4 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 08:50:00 7 0.4 8 5.7 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 8 5 4 305 0 0 0 0 1.6 0 2.2 1.3 10/13/2004 09:00:00 7.2 0.4 8.4 6.1 7.3 0.5 8.8 6.1 0.4 0 0.4 0.4 13 4 10 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 09:10:00 6.9 0.5 8.4 5.3 7 0.5 8.8 5.7 0.4 0 0.4 0.4 12 5 5 305 0 0 0 0 1.5 0 2 1.5 10/13/2004 09:20:00 6.7 0.4 7.6 5.7 6.8 0.4 7.6 5.7 0.4 0 0.4 0.4 16 6 9 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 09:30:00 6.7 0.4 7.6 5.3 6.9 0.4 7.6 5.7 0.4 0 0.4 0.4 13 4 12 305 0 0 0 0 1.4 0 1.5 1.3 10/13/2004 09:40:00 6.8 0.4 8 5.7 7 0.4 7.6 6.1 0.4 0 0.4 0.4 13 3 15 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 09:50:00 6.4 0.5 8 5.3 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 20 5 24 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 10:00:00 6.3 0.4 7.2 5.3 6.4 0.4 7.6 5.3 0.4 0 0.4 0.4 16 4 23 305 0 0 0 0 1.4 0 1.7 1.3 10/13/2004 10:10:00 6 0.4 7.2 4.6 6.1 0.4 7.2 4.9 0.4 0 0.4 0.4 14 5 9 305 0 0 0 0 1.4 0 1.7 1.3 10/13/2004 10:20:00 5.9 0.5 6.8 4.2 6 0.5 7.2 4.2 0.4 0 0.4 0.4 16 5 23 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 10:30:00 5.6 0.4 6.8 4.6 5.6 0.5 6.8 4.6 0.4 0 0.4 0.4 25 5 22 305 0 0 0 0 1.3 0 1.7 1.3 10/13/2004 10:40:00 5.6 0.4 6.8 4.6 5.6 0.4 6.8 4.6 0.4 0 0.4 0.4 21 5 17 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 10:50:00 5.5 0.4 6.5 4.6 5.5 0.4 6.5 4.6 0.4 0 0.4 0.4 24 3 23 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 11:00:00 5.5 0.5 6.5 4.2 5.5 0.5 6.8 3.8 0.4 0 0.4 0.4 23 4 19 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 11:10:00 5.6 0.3 6.5 4.9 5.5 0.3 6.5 4.6 0.4 0 0.4 0.4 31 7 27 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 11:20:00 5.3 0.5 6.5 4.2 5.2 0.5 6.5 3.8 0.4 0 0.4 0.4 35 5 40 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 11:30:00 5.2 0.4 6.1 4.2 5.1 0.4 6.1 4.2 0.4 0 0.4 0.4 39 5 44 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 11:40:00 4.8 0.4 6.1 3.8 4.7 0.4 6.1 3.4 0.4 0 0.4 0.4 36 6 37 305 0 0 0 0 1.9 0 2.5 1.7 10/13/2004 11:50:00 4.6 0.4 5.7 3.8 4.6 0.4 5.3 3.4 0.4 0 0.4 0.4 35 5 30 305 0 0 0 0 1.9 0 2.5 1.7 10/13/2004 12:00:00 4.7 0.4 5.7 3.4 4.6 0.4 5.7 3.8 0.4 0 0.4 0.4 37 7 32 305 0 0 0 0 1.9 0 2.5 2 10/13/2004 12:10:00 4.3 0.5 5.3 3.4 4.2 0.4 5.3 3.4 0.4 0 0.4 0.4 41 6 51 305 0 0 0 0 2 0 2.5 2 10/13/2004 12:20:00 3.7 0.4 4.9 3 3.8 0.4 4.9 3 0.4 0 0.4 0.4 32 6 48 305 0 0 0 0 2 0 2.5 2 10/13/2004 12:30:00 3.3 0.4 4.2 2.3 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 39 7 32 305 0 0 0 0 2 0 2.5 2 10/13/2004 12:40:00 3 0.4 4.2 1.9 3.2 0.4 4.2 2.3 0.4 0 0.4 0.4 32 7 29 305 0 0 0 0 2 0 2.5 2 10/13/2004 12:50:00 3.1 0.4 3.8 1.9 3.2 0.4 4.2 2.3 0.4 0 0.4 0.4 35 6 31 305 0 0 0 0 2.1 0 2.5 2 10/13/2004 13:00:00 2.4 0.6 3.8 0.4 2.7 0.5 3.8 1.5 0.4 0 0.4 0.4 33 6 36 305 0 0 0 0 2 0 2.5 2 10/13/2004 13:10:00 1.9 0.5 3 0.7 2.2 0.3 3.4 1.5 0.4 0 0.4 0.4 35 10 66 305 0 0 0 0 2.1 0 2.5 2 10/13/2004 13:20:00 1.9 0.6 3 0.4 2.3 0.4 3.4 1.5 0.4 0 0.4 0.4 39 7 42 305 0 0 0 0 2.2 0 2.5 2 10/13/2004 13:30:00 1.3 0.6 2.3 0.4 1.9 0.4 2.6 1.1 0.4 0 0.4 0.4 41 13 47 305 0 0 0 0 2.2 0 2.5 2.2 10/13/2004 13:40:00 0.8 0.6 2.3 0.4 1.4 0.5 2.6 0.4 0.4 0 0.4 0.4 66 13 77 305 0 0 0 0 2.2 0.1 2.7 2.2 10/13/2004 13:50:00 0.8 0.5 1.9 0.4 1.4 0.4 2.3 0.4 0.4 0 0.4 0.4 70 13 69 305 0 0 0 0 2.4 0 2.9 2.2 10/13/2004 14:00:00 0.5 0.4 1.9 0.4 1.1 0.5 2.3 0.4 0.4 0 0.4 0.4 51 6 60 305 0 0 0 0 2.6 0 3.2 2.5 10/13/2004 14:10:00 1.3 0.6 2.6 0.4 1.8 0.4 2.6 0.7 0.4 0 0.4 0.4 42 6 35 305 0 0 0 0 2.6 0 2.9 2.5 10/13/2004 14:20:00 1.5 0.5 2.6 0.4 2 0.4 3 1.1 0.4 0 0.4 0.4 38 8 43 305 0 0 0 0 2.6 0 3.2 2.5 10/13/2004 14:30:00 2.5 0.3 3.4 1.5 2.8 0.3 3.4 1.9 0.4 0 0.4 0.4 58 6 66 305 0 0 0 0 2.7 0 3.2 2.5 10/13/2004 14:40:00 2.9 0.5 4.2 1.5 3.1 0.4 4.2 1.9 0.4 0 0.4 0.4 62 8 60 305 0 0 0 0 3.3 0.2 3.7 2.7 10/13/2004 14:50:00 2.2 0.5 3.4 1.1 2.5 0.4 3.4 1.5 0.4 0 0.4 0.4 49 10 56 305 0 0 0 0 3.2 0.3 3.9 2.7 10/13/2004 15:00:00 1.7 0.4 2.6 0.7 2.2 0.3 3 1.5 0.4 0 0.4 0.4 43 21 35 305 0 0 0 0 2.6 0 3.2 2.5 10/13/2004 15:10:00 1.1 0.6 2.3 0.4 1.7 0.6 3 0.4 0.4 0 0.4 0.4 98 12 106 305 0 0 0 0 3 0.2 3.7 2.5 10/13/2004 15:20:00 0.7 0.5 2.3 0.4 1.4 0.6 2.6 0.4 0.4 0 0.4 0.4 131 22 143 305 0 0 0 0 3.2 0.2 3.7 2.9 10/13/2004 15:30:00 0.9 0.5 2.3 0.4 1.5 0.6 2.6 0.4 0.4 0 0.4 0.4 167 20 196 305 0 0 0 0 2.9 0.1 3.4 2.7 10/13/2004 15:40:00 2.2 0.6 3.4 0.7 2.6 0.4 3.8 1.5 0.4 0 0.4 0.4 197 13 224 305 0 0 0 0 2.8 0.1 3.2 2.5 10/13/2004 15:50:00 2.3 1 4.2 0.4 2.7 0.8 4.6 1.1 0.4 0 0.4 0.4 201 8 208 305 0 0 0 0 2.6 0.2 3.2 2.2 10/13/2004 16:00:00 3.6 1.1 6.1 0.7 3.7 1 6.1 1.9 0.4 0 0.4 0.4 234 9 250 305 0 0 0 0 2.2 0.1 2.7 2 10/13/2004 16:10:00 3.6 0.8 5.3 1.9 3.7 0.7 4.9 2.3 0.4 0 0.4 0.4 214 17 239 305 0 0 0 0 2.1 0.2 2.9 1.7 10/13/2004 16:20:00 2.4 0.4 3.4 1.1 2.7 0.4 3.8 1.5 0.4 0 0.4 0.4 201 11 192 305 0 0 0 0 2.8 0.1 3.4 2.5 10/13/2004 16:30:00 2.7 0.5 3.8 1.5 2.9 0.5 4.2 1.9 0.4 0 0.4 0.4 215 8 228 305 0 0 0 0 2.8 0.1 3.4 2.7 10/13/2004 16:40:00 2.7 0.4 3.8 1.5 2.8 0.4 4.2 1.9 0.4 0 0.4 0.4 215 9 216 305 0 0 0 0 3.1 0 3.4 2.9 10/13/2004 16:50:00 2.2 0.4 3 0.7 2.5 0.4 3.4 1.5 0.4 0 0.4 0.4 214 9 211 305 0 0 0 0 2.9 0.1 3.4 2.9 10/13/2004 17:00:00 2.1 0.5 3.4 0.7 2.4 0.4 3.8 1.1 0.4 0 0.4 0.4 226 13 234 305 0 0 0 0 2.8 0.1 3.4 2.5 10/13/2004 17:10:00 2.4 0.5 3.8 0.7 2.4 0.6 4.2 1.1 0.4 0 0.4 0.4 260 15 261 305 0 0 0 0 2.5 0.2 3.2 2.2 10/13/2004 17:20:00 2.6 0.6 4.2 0.7 2.5 0.5 4.2 1.1 0.4 0 0.4 0.4 256 12 258 305 0 0 0 0 2.2 0 2.7 2 10/13/2004 17:30:00 3.8 0.7 4.9 1.5 3.9 0.7 5.3 1.5 0.4 0 0.4 0.4 305 15 305 305 0 0 0 0 2 0.1 2.5 1.7 10/13/2004 17:40:00 3.4 0.7 4.9 1.9 3.5 0.7 4.6 2.3 0.4 0 0.4 0.4 298 5 294 305 0 0 0 0 1.5 0 2.2 1.3 10/13/2004 17:50:00 1 0.7 2.6 0.4 1.5 0.7 3 0.4 0.4 0 0.4 0.4 302 5 287 305 0 0 0 0 1.4 0 1.7 1.3 10/13/2004 18:00:00 0.4 0 0.7 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 311 14 307 305 0 0 0 0 1.5 0 2 1.5 10/13/2004 18:10:00 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 331 9 305 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 327 0 305 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 18:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 339 8 305 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 305 305 0 0 0 0 1.5 0 2 1.5 10/13/2004 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 305 305 0 0 0 0 1.5 0 2 1.5 10/13/2004 19:00:00 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 274 58 240 305 0 0 0 0 1.6 0 1.5 1.5 10/13/2004 19:10:00 0.8 0.6 2.3 0.4 1.3 0.5 2.6 0.4 0.4 0 0.4 0.4 206 4 213 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 19:20:00 3.9 0.9 5.7 1.9 4 0.8 5.7 2.3 0.4 0 0.4 0.4 214 7 209 305 0 0 0 0 1.4 0.3 2.2 1 10/13/2004 19:30:00 3.2 0.5 4.2 1.9 3.5 0.6 4.6 1.9 0.4 0 0.4 0.4 194 13 184 305 0 0 0 0 1.1 0 1.5 1 10/13/2004 19:40:00 1 0.5 2.3 0.4 2 0.5 3.4 1.1 0.4 0 0.4 0.4 168 10 177 305 0 0 0 0 1 0 1.5 0.8 10/13/2004 19:50:00 0.8 0.4 1.9 0.4 1.8 0.5 3 0.7 0.4 0 0.4 0.4 173 12 155 305 0 0 0 0 1 0 1.5 0.8 10/13/2004 20:00:00 0.9 0.4 1.9 0.4 1.6 0.3 2.3 0.7 0.4 0 0.4 0.4 192 6 197 305 0 0 0 0 1.2 0.1 1.5 1 10/13/2004 20:10:00 2.2 0.6 3.4 0.7 2.7 0.6 3.8 1.1 0.4 0 0.4 0.4 192 9 190 305 0 0 0 0 1.5 0 2 1.3 10/13/2004 20:20:00 2.1 1.3 5.3 0.4 2.7 1.2 5.7 1.1 0.4 0 0.4 0.4 194 15 186 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 20:30:00 3.1 0.7 4.6 1.5 4 0.5 4.9 2.6 0.4 0 0.4 0.4 175 10 180 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 20:40:00 3.1 0.8 4.9 1.5 4.2 0.4 5.3 3 0.4 0 0.4 0.4 170 9 154 305 0 0 0 0 1.3 0 1.7 1.3 10/13/2004 20:50:00 3.7 1.3 6.5 0.7 4.1 1.1 6.5 1.9 0.4 0 0.4 0.4 191 15 193 305 0 0 0 0 1.3 0 1.7 1.3 10/13/2004 21:00:00 2.3 0.8 4.6 0.7 2.7 0.8 4.9 1.1 0.4 0 0.4 0.4 214 11 222 305 0 0 0 0 1.6 0 2 1.3 10/13/2004 21:10:00 1.5 0.8 3.8 0.4 1.9 0.6 3.4 0.7 0.4 0 0.4 0.4 223 18 257 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 21:20:00 3.1 0.6 4.6 1.5 3.2 0.6 4.9 1.9 0.4 0 0.4 0.4 222 26 202 305 0 0 0 0 1.9 0 2.5 1.5 10/13/2004 21:30:00 3.7 0.6 4.9 1.9 4.2 0.5 5.3 2.6 0.4 0 0.4 0.4 183 4 196 305 0 0 0 0 1.7 0.1 2.5 1.5 10/13/2004 21:40:00 3.4 0.8 4.9 1.5 4.3 0.4 5.3 3 0.4 0 0.4 0.4 179 5 179 305 0 0 0 0 1.7 0.1 2.2 1.5 10/13/2004 21:50:00 2.6 0.6 3.8 0.7 3.8 0.5 4.9 2.6 0.4 0 0.4 0.4 173 5 159 305 0 0 0 0 1.8 0.1 2.2 1.7 10/13/2004 22:00:00 2.5 0.6 4.2 0.7 3.7 0.5 5.3 2.6 0.4 0 0.4 0.4 172 8 174 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 22:10:00 3.2 1 5.3 1.1 4.1 0.6 6.5 2.6 0.4 0 0.4 0.4 177 10 188 305 0 0 0 0 1.6 0 2 1.5 10/13/2004 22:20:00 2.9 1 5.3 1.1 4.1 0.6 5.7 2.6 0.4 0 0.4 0.4 172 9 191 305 0 0 0 0 1.6 0 2 1.3 10/13/2004 22:30:00 2.9 0.7 4.2 1.1 3.6 0.4 4.6 2.3 0.4 0 0.4 0.4 173 14 194 305 0 0 0 0 1.4 0 2 1.3 10/13/2004 22:40:00 2.6 0.7 4.6 1.1 3.6 0.6 5.3 2.3 0.4 0 0.4 0.4 171 9 186 305 0 0 0 0 1.5 0 2 1.3 10/13/2004 22:50:00 3.6 1.1 6.5 1.5 4.3 0.8 6.8 2.6 0.4 0 0.4 0.4 184 12 198 305 0 0 0 0 1.6 0 2.2 1.5 10/13/2004 23:00:00 3.7 1.2 6.8 0.7 3.7 1.1 6.5 0.7 0.4 0 0.4 0.4 214 17 227 305 0 0 0 0 2 0.1 2.7 2 10/13/2004 23:10:00 6.4 1 9.9 4.2 6 1 8.8 3.8 0.4 0 0.4 0.4 234 7 234 305 0 0 0 0 2.5 0 2.9 2.2 10/13/2004 23:20:00 6.5 0.6 8 4.6 6.3 0.7 8 3.8 0.4 0 0.4 0.4 224 9 225 305 0 0 0 0 2.5 0 2.9 2.5 10/13/2004 23:30:00 7 0.8 9.1 4.9 6.7 0.8 8.8 4.6 0.4 0 0.4 0.4 225 6 220 305 0 0 0 0 2.6 0 2.9 2.5 10/13/2004 23:40:00 7.6 0.7 10.3 5.7 7.2 0.8 9.5 4.9 0.4 0 0.4 0.4 224 7 207 305 0 0 0 0 2.6 0 2.9 2.5 10/13/2004 23:50:00 7.2 1.3 9.9 3.8 6.8 1.3 9.5 4.2 0.4 0 0.4 0.4 228 6 221 305 0 0 0 0 2.4 0 2.9 2.2 10/14/2004 00:00:00 7.2 0.9 9.1 4.9 6.8 0.9 8.8 4.6 0.4 0 0.4 0.4 223 5 221 305 0 0 0 0 2.5 0 2.9 2.5 10/14/2004 00:10:00 5.9 0.6 7.6 4.6 5.6 0.8 7.6 3.8 0.4 0 0.4 0.4 216 6 219 305 0 0 0 0 2.4 0 2.9 2.2 10/14/2004 00:20:00 7.1 0.7 9.1 4.9 6.8 0.8 9.1 4.6 0.4 0 0.4 0.4 215 7 217 305 0 0 0 0 2.6 0 2.9 2.5 10/14/2004 00:30:00 7.4 1.5 10.3 4.2 7.2 1.4 9.5 3.8 0.4 0 0.4 0.4 213 6 219 305 0 0 0 0 2.6 0 2.9 2.5 10/14/2004 00:40:00 7.2 1.3 10.3 4.2 7 1.3 9.9 4.2 0.4 0 0.4 0.4 216 7 230 305 0 0 0 0 2.6 0 2.9 2.5 10/14/2004 00:50:00 7.3 0.8 8.8 5.3 6.9 0.9 9.1 4.2 0.4 0 0.4 0.4 217 11 208 305 0 0 0 0 2.6 0 3.2 2.5 10/14/2004 01:00:00 8.3 0.7 9.9 6.5 7.8 0.8 9.9 5.7 0.4 0 0.4 0.4 225 6 227 305 0 0 0 0 2.6 0 2.9 2.5 10/14/2004 01:10:00 7.9 0.9 9.9 4.9 7.5 1 9.9 4.9 0.4 0 0.4 0.4 220 6 225 305 0 0 0 0 2.6 0 2.9 2.5 10/14/2004 01:20:00 7.2 1 9.1 4.6 6.8 1 8.8 4.6 0.4 0 0.4 0.4 217 6 220 305 0 0 0 0 2.5 0 2.9 2.5 10/14/2004 01:30:00 6.3 0.8 8 4.2 6 0.8 8 4.2 0.4 0 0.4 0.4 220 5 216 305 0 0 0 0 2.5 0 2.9 2.5 10/14/2004 01:40:00 6.9 0.6 8.4 5.3 6.6 0.6 8 4.9 0.4 0 0.4 0.4 222 5 223 305 0 0 0 0 2.4 0 2.7 2.2 10/14/2004 01:50:00 7 0.8 8.8 4.9 6.7 0.9 8.8 4.6 0.4 0 0.4 0.4 221 5 217 305 0 0 0 0 2.5 0 2.9 2.5 10/14/2004 02:00:00 7.5 0.6 8.8 4.9 7 0.7 8.4 4.6 0.4 0 0.4 0.4 226 6 224 305 0 0 0 0 2.6 0 2.9 2.5 10/14/2004 02:10:00 6.3 0.6 7.6 4.6 6 0.7 8 4.2 0.4 0 0.4 0.4 215 6 218 305 0 0 0 0 2.6 0 2.9 2.5 10/14/2004 02:20:00 6.9 0.7 8.8 5.3 6.5 0.7 8.8 4.6 0.4 0 0.4 0.4 215 6 220 305 0 0 0 0 2.6 0 2.9 2.5 10/14/2004 02:30:00 7.1 0.6 8.8 5.3 7.1 0.6 8.8 5.3 0.4 0 0.4 0.4 204 4 203 305 0 0 0 0 2.7 0 3.2 2.5 10/14/2004 02:40:00 7.5 0.6 8.8 4.9 7.4 0.8 8.8 4.6 0.4 0 0.4 0.4 205 5 201 305 0 0 0 0 2.7 0 3.2 2.7 10/14/2004 02:50:00 6.7 1 9.5 3.8 6.9 0.9 9.5 3.8 0.4 0 0.4 0.4 187 8 199 305 0 0 0 0 2.4 0.1 2.9 2.2 10/14/2004 03:00:00 7.3 0.6 8.4 4.9 7.6 0.5 8.8 6.1 0.4 0 0.4 0.4 184 3 183 305 0 0 0 0 2.2 0 2.5 2.2 10/14/2004 03:10:00 7.8 0.4 8.4 6.1 7.9 0.4 8.8 6.5 0.4 0 0.4 0.4 185 2 183 305 0 0 0 0 2.2 0 2.7 2.2 10/14/2004 03:20:00 7.9 0.7 9.9 5.3 8.1 0.8 10.7 6.5 0.4 0 0.4 0.4 184 3 186 305 0 0 0 0 2.3 0 2.7 2.2 10/14/2004 03:30:00 7.1 0.9 9.9 4.6 7.5 0.8 10.7 5.7 0.4 0 0.4 0.4 183 5 185 305 0 0 0 0 2.3 0.1 2.7 2.2 10/14/2004 03:40:00 6.5 1.2 8.8 3 7.5 0.9 9.1 4.9 0.4 0 0.4 0.4 179 5 182 305 0 0 0 0 2.4 0 2.9 2.2 10/14/2004 03:50:00 6.6 1.5 9.1 3.8 7.7 1 10.3 4.9 0.4 0 0.4 0.4 178 6 180 305 0 0 0 0 2.5 0 2.9 2.5 10/14/2004 04:00:00 5.3 0.8 8 3 7 0.7 9.5 4.9 0.4 0 0.4 0.4 171 7 152 305 0 0 0 0 2.5 0 2.9 2.2 10/14/2004 04:10:00 6.6 1.1 10.3 4.2 8.7 0.9 11.8 6.5 0.4 0 0.4 0.4 172 6 157 305 0 0 0 0 2.7 0 3.2 2.5 10/14/2004 04:20:00 5.7 1 9.1 3.8 7.4 1 9.9 4.9 0.4 0 0.4 0.4 168 7 179 305 0 0 0 0 2.5 0.2 2.9 2.2 10/14/2004 04:30:00 7.2 1.2 10.3 4.2 9.1 1.1 12.6 6.1 0.4 0 0.4 0.4 172 7 171 305 0 0 0 0 2.6 0.2 3.2 2.2 10/14/2004 04:40:00 7.1 1 10.3 4.6 9.4 1 11.5 6.5 0.4 0 0.4 0.4 170 5 169 305 0 0 0 0 2.6 0 2.9 2.5 10/14/2004 04:50:00 7 1 9.9 4.9 9.2 1 11.8 6.5 0.4 0 0.4 0.4 169 5 172 305 0 0 0 0 2.6 0 2.9 2.5 10/14/2004 05:00:00 7.2 1 9.9 4.6 9.1 0.8 12.2 6.8 0.4 0 0.4 0.4 167 5 166 305 0 0 0 0 2.6 0 3.2 2.5 10/14/2004 05:10:00 8 1.2 10.7 4.6 8.6 0.8 11.5 6.1 0.4 0 0.4 0.4 161 6 163 305 0 0 0 0 2.3 0.1 2.9 2.2 10/14/2004 05:20:00 7.5 1 10.3 5.3 7.9 0.8 9.9 5.7 0.4 0 0.4 0.4 159 6 154 305 0 0 0 0 2.2 0 2.5 2.2 10/14/2004 05:30:00 8 1.1 10.3 4.9 8.6 0.7 10.7 7.2 0.4 0 0.4 0.4 161 5 163 305 0 0 0 0 2.2 0 2.7 2.2 10/14/2004 05:40:00 8.2 1.2 11.1 5.3 9 0.7 10.7 6.8 0.4 0 0.4 0.4 161 6 155 305 0 0 0 0 2.4 0 2.9 2.2 10/14/2004 05:50:00 8.1 1.1 11.1 5.3 8.4 1 11.8 6.1 0.4 0 0.4 0.4 159 6 150 305 0 0 0 0 2.5 0 2.9 2.5 10/14/2004 06:00:00 8 1 11.1 5.7 8 0.8 10.7 6.1 0.4 0 0.4 0.4 155 7 154 305 0 0 0 0 2.5 0 2.9 2.2 10/14/2004 06:10:00 8.6 1.3 11.5 4.9 8.5 1.1 11.1 5.7 0.4 0 0.4 0.4 154 8 153 305 0 0 0 0 2.6 0 3.2 2.5 10/14/2004 06:20:00 9.9 1.2 12.6 6.1 9.8 1 12.6 6.5 0.4 0 0.4 0.4 154 6 152 305 1 0 1 0 2.8 0.1 3.2 2.7 10/14/2004 06:30:00 9.7 1.1 12.6 6.8 9.5 1 11.8 7.2 0.4 0 0.4 0.4 154 6 148 305 1 0 1 0 2.9 0 3.4 2.7 10/14/2004 06:40:00 9.7 1 12.6 6.8 9.5 0.9 11.5 7.6 0.4 0 0.4 0.4 157 5 147 305 1 0 1 0 3 0 3.4 2.9 10/14/2004 06:50:00 9 1 11.8 6.8 8.9 0.9 11.5 6.1 0.4 0 0.4 0.4 156 6 157 305 1 0 1 0 3.2 0 3.7 2.9 10/14/2004 07:00:00 9.1 1.4 11.8 5.3 9.2 0.9 12.2 7.2 0.4 0 0.4 0.4 158 6 159 305 1 0 1 0 3.3 0 3.7 3.2 10/14/2004 07:10:00 7.8 1.2 10.3 4.6 8.8 0.7 10.7 7.2 0.4 0 0.4 0.4 163 7 171 305 1 0 1 0 3.3 0 3.7 3.2 10/14/2004 07:20:00 7.9 1.1 10.7 5.3 9.8 1.1 13 6.8 0.4 0 0.4 0.4 169 7 156 305 1 0 1 0 4 0.2 4.9 3.4 10/14/2004 07:30:00 8 1.2 11.1 4.9 9.9 1.1 12.6 6.5 0.4 0 0.4 0.4 169 7 169 305 1 0 1 0 4.6 0.2 5.4 4.2 10/14/2004 07:40:00 7.7 1.3 10.7 5.3 9.6 1 11.8 6.5 0.4 0 0.4 0.4 174 7 181 305 1 0 1 0 5.1 0.1 5.6 4.9 10/14/2004 07:50:00 7.6 1.2 10.7 4.6 9.5 1.1 12.2 6.5 0.4 0 0.4 0.4 173 7 183 305 1 0 0 0 5.1 0 5.6 4.9 10/14/2004 08:00:00 9.1 1.8 13 4.6 10.7 1.4 13.7 7.6 0.4 0 0.4 0.4 177 6 180 305 0 0 0 0 5.2 0 5.6 4.9 10/14/2004 08:10:00 10.5 1.2 13 6.5 11.7 0.9 14.1 8.8 0.4 0 0.4 0.4 180 4 188 305 0 0 0 0 5 0.1 5.6 4.9 10/14/2004 08:20:00 9.7 1.3 12.2 5.7 10.6 1 13 6.8 0.4 0 0.4 0.4 180 5 185 305 0 0 0 0 4.9 0.1 5.4 4.9 10/14/2004 08:30:00 9 1.2 11.5 5.3 10 0.8 11.8 8 0.4 0 0.4 0.4 180 5 183 305 0 0 0 0 4.9 0.1 5.4 4.7 10/14/2004 08:40:00 8.8 1.1 11.5 6.1 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 182 4 187 305 0 0 0 0 4.8 0 5.4 4.7 10/14/2004 08:50:00 8.7 1 11.5 5.7 9.6 0.9 12.2 7.6 0.4 0 0.4 0.4 180 5 186 305 0 0 0 0 4.9 0.1 5.4 4.7 10/14/2004 09:00:00 8.7 1.2 11.1 5.3 9.4 1 12.2 6.5 0.4 0 0.4 0.4 180 5 182 305 0 0 0 0 4.9 0.1 5.4 4.9 10/14/2004 09:10:00 8.7 1 11.1 6.1 9.2 0.8 11.1 6.5 0.4 0 0.4 0.4 182 4 185 305 0 0 0 0 4.8 0 5.4 4.7 10/14/2004 09:20:00 9.1 0.7 11.5 7.2 9.2 0.6 11.5 7.2 0.4 0 0.4 0.4 185 4 197 305 0 0 0 0 4.7 0.1 5.2 4.7 10/14/2004 09:30:00 9.7 0.9 11.5 6.5 9.6 0.8 11.8 7.6 0.4 0 0.4 0.4 185 4 188 305 0 0 0 0 4.7 0.1 5.2 4.4 10/14/2004 09:40:00 9 1 11.8 6.5 9.2 1 11.8 6.8 0.4 0 0.4 0.4 184 5 184 305 0 0 1 0 4.8 0.1 5.4 4.7 10/14/2004 09:50:00 9.5 1 11.8 6.5 9.6 0.9 12.2 7.2 0.4 0 0.4 0.4 185 4 188 305 1 0 1 0 5 0.1 5.4 4.7 10/14/2004 10:00:00 10.4 0.9 12.6 8 10.3 1 13 7.2 0.4 0 0.4 0.4 188 4 187 305 1 0 1 0 5 0.2 5.6 4.9 10/14/2004 10:10:00 11.1 1 13.3 8.8 10.9 1 13.3 7.6 0.4 0 0.4 0.4 187 4 190 305 1 0 1 0 5.2 0.2 5.6 4.9 10/14/2004 10:20:00 11.1 1.1 14.1 7.2 11 1 13.7 7.2 0.4 0 0.4 0.4 186 5 197 305 1 0 1 0 5.3 0.1 5.9 4.9 10/14/2004 10:30:00 11.5 1.1 14.1 8.8 11.5 1.1 14.1 8.8 0.4 0 0.4 0.4 186 4 188 305 1 0 1 0 5.4 0.1 5.9 5.2 10/14/2004 10:40:00 10.7 1.3 13.7 7.2 10.8 1.2 14.1 8 0.4 0 0.4 0.4 185 4 188 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 10:50:00 10.6 1.3 13.3 6.5 10.8 1.2 13 6.8 0.4 0 0.4 0.4 185 5 188 305 1 0 1 0 5.5 0.2 5.9 5.4 10/14/2004 11:00:00 11.2 1.2 13.3 7.2 11 1.1 13.7 7.6 0.4 0 0.4 0.4 187 5 191 305 1 0 1 0 5.4 0 5.9 5.4 10/14/2004 11:10:00 11.8 1 14.9 9.1 11.5 1.1 14.9 8 0.4 0 0.4 0.4 188 4 189 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 11:20:00 12.4 1 15.3 9.9 12 1.1 14.9 8.8 0.4 0 0.4 0.4 188 4 189 305 1 0 1 0 5.6 0.1 5.9 5.4 10/14/2004 11:30:00 12.9 1.2 16.4 9.5 12.4 1.2 16.4 8.4 0.4 0 0.4 0.4 190 5 197 305 1 0 0 0 5.6 0 6.1 5.6 10/14/2004 11:40:00 13.3 1.2 16.1 9.5 12.7 1.2 15.3 8.4 0.4 0 0.4 0.4 190 4 196 305 0 0 0 0 5.8 0 6.1 5.6 10/14/2004 11:50:00 14.2 1.3 17.6 10.7 13.5 1.4 17.2 9.9 0.4 0 0.4 0.4 191 4 194 305 0 0 0 0 5.9 0 6.4 5.6 10/14/2004 12:00:00 14.9 1.3 17.6 11.5 14.1 1.5 17.2 9.9 0.4 0 0.4 0.4 193 4 194 305 0 0 0 0 5.9 0 6.4 5.6 10/14/2004 12:10:00 14.7 1.3 17.9 10.3 13.8 1.6 17.9 8.8 0.4 0 0.4 0.4 191 5 188 305 0 0 1 0 5.8 0.1 6.4 5.6 10/14/2004 12:20:00 14.1 1 17.2 11.1 13.6 1.3 16.8 9.5 0.4 0 0.4 0.4 190 4 184 305 1 0 1 0 5.6 0.1 5.9 5.4 10/14/2004 12:30:00 14.2 1.3 17.6 10.7 13.9 1.5 17.6 9.9 0.4 0 0.4 0.4 188 5 189 305 1 0 1 0 5.8 0 6.1 5.6 10/14/2004 12:40:00 14.3 1.2 18.3 11.5 13.9 1.2 17.2 11.1 0.4 0 0.4 0.4 189 4 189 305 1 0 1 0 5.9 0 6.4 5.6 10/14/2004 12:50:00 14.5 1.3 17.6 9.9 14 1.6 17.6 9.9 0.4 0 0.4 0.4 190 5 183 305 1 0 1 0 6 0.1 6.4 5.9 10/14/2004 13:00:00 15.5 1.6 19.1 10.7 15 1.9 19.1 9.9 0.4 0 0.4 0.4 190 4 192 305 1 0 1 0 6 0.1 6.4 5.9 10/14/2004 13:10:00 14.8 1.5 18.3 11.8 14.4 1.6 18.3 9.9 0.4 0 0.4 0.4 189 5 191 305 1 0 0 0 6.1 0.1 6.4 5.9 10/14/2004 13:20:00 14.8 1.3 19.1 11.8 14.8 1.3 18.3 11.1 0.4 0 0.4 0.4 187 4 190 305 0 0 0 0 6 0.1 6.4 5.9 10/14/2004 13:30:00 14.9 1.3 19.1 10.3 14.5 1.5 17.6 9.5 0.4 0 0.4 0.4 188 5 192 305 0 0 0 0 5.9 0 6.4 5.9 10/14/2004 13:40:00 15.3 1.3 18.3 11.1 14.9 1.5 18.7 9.5 0.4 0 0.4 0.4 189 5 183 305 0 0 0 0 5.9 0 6.1 5.6 10/14/2004 13:50:00 15.2 1.4 19.1 11.1 14.6 1.5 19.5 9.9 0.4 0 0.4 0.4 190 5 192 305 1 0 1 0 5.6 0.1 6.1 5.4 10/14/2004 14:00:00 14.8 1.3 17.9 10.7 14.2 1.4 17.6 9.9 0.4 0 0.4 0.4 189 4 203 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 14:10:00 13.3 1.5 17.2 8 13.1 1.4 16.8 9.5 0.4 0 0.4 0.4 187 5 196 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 14:20:00 13.8 1.7 17.6 8.8 14.5 1.7 18.7 10.3 0.4 0 0.4 0.4 184 5 194 305 1 0 1 0 5.8 0.1 6.1 5.4 10/14/2004 14:30:00 14.3 1.9 18.7 8 14.6 1.6 18.3 9.9 0.4 0 0.4 0.4 184 5 190 305 1 0 1 0 5.9 0.1 6.4 5.6 10/14/2004 14:40:00 14 1.7 17.9 9.1 14.2 1.7 18.3 9.5 0.4 0 0.4 0.4 186 5 188 305 1 0 1 0 5.8 0.1 6.1 5.6 10/14/2004 14:50:00 14.3 1.8 18.3 8.4 14.3 1.5 18.3 9.1 0.4 0 0.4 0.4 186 5 189 305 1 0 1 0 5.8 0 6.1 5.6 10/14/2004 15:00:00 14.7 2.4 22.9 7.2 14.8 2.2 22.1 9.9 0.4 0 0.4 0.4 186 5 194 305 1 0 1 0 5.7 0 6.1 5.6 10/14/2004 15:10:00 16.1 1.8 21.4 12.2 15.3 1.8 19.9 10.7 0.4 0 0.4 0.4 190 5 193 305 1 0 1 0 5.6 0.1 6.1 5.4 10/14/2004 15:20:00 12.9 1.5 17.6 7.6 13.4 1.5 17.9 9.9 0.4 0 0.4 0.4 184 6 187 305 1 0 1 0 5.5 0 5.9 5.4 10/14/2004 15:30:00 15.3 1.5 18.7 11.1 15.2 1.5 18.7 10.3 0.4 0 0.4 0.4 188 5 183 305 1 0 1 0 5.5 0 5.9 5.4 10/14/2004 15:40:00 14.1 1.7 19.9 9.5 14.5 1.5 19.1 10.3 0.4 0 0.4 0.4 184 5 186 305 1 0 1 0 5.4 0 5.9 5.4 10/14/2004 15:50:00 14.5 1.7 17.9 9.5 14.7 1.6 17.9 10.3 0.4 0 0.4 0.4 185 5 189 305 1 0 1 0 5.5 0 5.9 5.4 10/14/2004 16:00:00 12.8 2.1 17.9 7.2 13.9 1.8 19.5 9.1 0.4 0 0.4 0.4 181 6 187 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 16:10:00 14.5 1.8 20.2 9.5 15.1 1.8 21 10.7 0.4 0 0.4 0.4 184 5 183 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 16:20:00 13.8 1.7 17.6 9.5 14.2 1.5 17.9 10.3 0.4 0 0.4 0.4 185 5 186 305 1 0 1 0 5.4 0 5.9 5.4 10/14/2004 16:30:00 12.3 2 17.9 8 14.2 1.8 19.5 8.4 0.4 0 0.4 0.4 177 8 183 305 1 0 1 0 5.6 0.1 6.1 5.4 10/14/2004 16:40:00 12.5 1.9 17.6 8 14.3 1.7 18.7 9.1 0.4 0 0.4 0.4 180 6 184 305 1 0 1 0 5.6 0 6.1 5.4 10/14/2004 16:50:00 11.3 1.9 17.2 7.2 13.7 1.7 18.7 9.9 0.4 0 0.4 0.4 173 8 177 305 1 0 1 0 5.6 0 6.1 5.6 10/14/2004 17:00:00 11.3 1.8 17.9 7.6 13.9 1.8 18.3 9.5 0.4 0 0.4 0.4 175 7 181 305 1 0 1 0 5.7 0 6.1 5.6 10/14/2004 17:10:00 12 1.8 17.9 8 14.5 1.7 19.5 10.3 0.4 0 0.4 0.4 174 7 187 305 1 0 1 0 5.7 0 6.1 5.6 10/14/2004 17:20:00 11.8 1.8 16.8 7.6 14.6 1.7 20.2 10.7 0.4 0 0.4 0.4 173 7 181 305 1 0 1 0 5.7 0 6.1 5.6 10/14/2004 17:30:00 13.3 2 19.5 8.4 16.3 1.8 21.8 11.1 0.4 0 0.4 0.4 177 6 179 305 1 0 1 0 5.8 0 6.1 5.6 10/14/2004 17:40:00 11.5 1.8 17.2 6.8 14.1 1.8 19.5 9.9 0.4 0 0.4 0.4 172 7 159 305 1 0 1 0 5.7 0 6.1 5.6 10/14/2004 17:50:00 12.1 1.8 19.1 8 14.4 1.7 18.7 10.3 0.4 0 0.4 0.4 176 7 175 305 1 0 1 0 5.6 0 6.1 5.6 10/14/2004 18:00:00 11.5 2.1 17.9 6.1 13.7 1.7 17.9 9.1 0.4 0 0.4 0.4 175 7 186 305 1 0 1 0 5.7 0.1 6.1 5.6 10/14/2004 18:10:00 11.7 1.8 16.4 7.2 14.4 1.7 19.1 10.7 0.4 0 0.4 0.4 174 8 176 305 1 0 1 0 5.7 0.1 6.1 5.6 10/14/2004 18:20:00 12.2 2.1 17.9 6.8 14.7 2 20.2 9.5 0.4 0 0.4 0.4 176 7 177 305 1 0 1 0 5.7 0.1 6.1 5.6 10/14/2004 18:30:00 12.2 1.8 17.6 7.6 14.7 1.7 19.1 10.7 0.4 0 0.4 0.4 175 8 186 305 1 0 1 0 5.6 0.1 6.1 5.6 10/14/2004 18:40:00 11.9 1.9 17.6 7.2 14.4 2.1 19.9 9.1 0.4 0 0.4 0.4 176 7 173 305 1 0 1 0 5.6 0.1 6.1 5.6 10/14/2004 18:50:00 12.5 1.7 17.2 7.6 15 1.7 19.1 9.1 0.4 0 0.4 0.4 177 6 184 305 1 0 1 0 5.6 0.1 6.1 5.6 10/14/2004 19:00:00 12.2 1.7 16.8 8.4 14.7 1.6 19.5 10.7 0.4 0 0.4 0.4 177 6 183 305 1 0 1 0 5.6 0.1 5.9 5.6 10/14/2004 19:10:00 12.4 1.9 19.1 7.6 14.5 1.9 20.2 9.9 0.4 0 0.4 0.4 178 6 185 305 1 0 1 0 5.6 0.1 6.1 5.4 10/14/2004 19:20:00 11.9 1.9 17.2 7.6 14.1 1.7 19.9 9.9 0.4 0 0.4 0.4 178 6 192 305 1 0 1 0 5.6 0.1 5.9 5.4 10/14/2004 19:30:00 13.1 2.1 18.7 8 15.6 1.7 20.6 10.3 0.4 0 0.4 0.4 178 6 184 305 1 0 1 0 5.6 0.1 5.9 5.6 10/14/2004 19:40:00 12.6 2.2 19.5 6.8 14.4 1.8 19.5 9.9 0.4 0 0.4 0.4 179 6 192 305 1 0 1 0 5.6 0.1 5.9 5.4 10/14/2004 19:50:00 12.6 1.6 16.8 8.8 15 1.6 20.6 11.5 0.4 0 0.4 0.4 176 6 183 305 1 0 1 0 5.6 0.1 5.9 5.4 10/14/2004 20:00:00 12.8 1.8 17.9 7.6 15.6 1.8 20.6 11.5 0.4 0 0.4 0.4 175 6 181 305 1 0 1 0 5.6 0.1 5.9 5.4 10/14/2004 20:10:00 12.9 1.9 18.7 8.8 15.7 1.8 20.2 11.8 0.4 0 0.4 0.4 176 6 183 305 1 0 1 0 5.7 0 6.1 5.6 10/14/2004 20:20:00 13.4 2.3 21.4 8.8 16 2.2 22.1 9.9 0.4 0 0.4 0.4 176 7 182 305 1 0 1 0 5.7 0.1 6.1 5.6 10/14/2004 20:30:00 12.6 2 17.9 8 15.4 1.7 20.2 10.7 0.4 0 0.4 0.4 176 7 182 305 1 0 1 0 5.6 0.1 6.1 5.6 10/14/2004 20:40:00 14.2 1.7 18.3 9.1 16.7 1.6 20.2 13 0.4 0 0.4 0.4 177 6 184 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 20:50:00 13.4 1.8 19.5 9.5 16 1.7 21.4 11.8 0.4 0 0.4 0.4 176 6 181 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 21:00:00 13.5 1.9 19.1 9.5 16.3 1.7 21 9.9 0.4 0 0.4 0.4 177 6 176 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 21:10:00 13.6 2 17.9 9.1 15.1 1.7 19.1 11.5 0.4 0 0.4 0.4 181 5 176 305 1 0 1 0 5.5 0 5.9 5.4 10/14/2004 21:20:00 13.8 2.2 19.1 8.8 15.9 1.8 20.6 10.3 0.4 0 0.4 0.4 179 7 182 305 1 0 1 0 5.5 0 5.9 5.4 10/14/2004 21:30:00 14.1 2.2 20.6 9.9 17.2 1.9 22.6 12.6 0.4 0 0.4 0.4 176 6 181 305 1 0 1 0 5.4 0 5.9 5.4 10/14/2004 21:40:00 13.4 1.9 18.7 9.1 16.3 1.7 19.9 11.8 0.4 0 0.4 0.4 176 7 194 305 1 0 1 0 5.5 0 5.9 5.4 10/14/2004 21:50:00 13.3 1.7 17.6 8.8 16 1.8 21 10.3 0.4 0 0.4 0.4 179 6 183 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 22:00:00 13.9 2 19.5 8.8 16.6 1.7 21.4 11.5 0.4 0 0.4 0.4 178 6 183 305 1 0 1 0 5.6 0.2 5.9 5.4 10/14/2004 22:10:00 13.8 1.9 19.5 8.8 16.5 1.9 21.8 11.8 0.4 0 0.4 0.4 178 6 189 305 1 0 1 0 5.6 0.1 5.9 5.4 10/14/2004 22:20:00 14.2 1.8 19.5 9.5 17 1.9 22.1 12.6 0.4 0 0.4 0.4 178 6 186 305 1 0 1 0 5.6 0.1 6.1 5.4 10/14/2004 22:30:00 13.9 2 19.1 9.1 16.8 1.7 21.4 11.8 0.4 0 0.4 0.4 178 6 183 305 1 0 1 0 5.6 0.1 5.9 5.4 10/14/2004 22:40:00 14.3 2 20.6 9.1 17.4 1.7 21.8 12.6 0.4 0 0.4 0.4 177 6 182 305 1 0 1 0 5.7 0.1 6.1 5.6 10/14/2004 22:50:00 14.6 2.5 21 9.9 17 2.2 22.9 11.5 0.4 0 0.4 0.4 175 6 176 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 23:00:00 14.6 2.4 22.6 9.1 16.9 2.2 22.1 11.5 0.4 0 0.4 0.4 175 7 183 305 1 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 23:10:00 14 2.1 19.5 8.4 16.6 1.9 21.8 11.5 0.4 0 0.4 0.4 175 7 186 305 2 0 1 0 5.5 0.1 5.9 5.4 10/14/2004 23:20:00 14.1 2.3 19.9 9.1 17 1.7 21.4 11.8 0.4 0 0.4 0.4 176 7 174 305 2 0 2 0 5.5 0.1 5.9 5.4 10/14/2004 23:30:00 14.2 2.2 20.2 9.5 16.6 1.7 21.4 11.5 0.4 0 0.4 0.4 174 8 177 305 2 0 2 0 5.6 0.1 5.9 5.4 10/14/2004 23:40:00 14.1 1.8 20.2 9.1 16.8 2 22.1 11.8 0.4 0 0.4 0.4 172 7 179 305 2 0 2 0 5.6 0.1 5.9 5.4 10/14/2004 23:50:00 13.9 2.3 19.9 9.5 16.4 1.8 22.1 11.8 0.4 0 0.4 0.4 175 7 172 305 2 0 1 0 5.6 0.1 5.9 5.4 10/15/2004 00:00:00 13.7 2.1 19.9 9.5 16.2 1.8 20.2 11.5 0.4 0 0.4 0.4 174 7 184 305 2 0 2 0 5.6 0.1 5.9 5.4 10/15/2004 00:10:00 14.1 2.6 21.4 8.4 16.2 2.3 22.9 11.1 0.4 0 0.4 0.4 175 7 177 305 2 0 2 0 5.6 0.1 5.9 5.4 10/15/2004 00:20:00 13.4 2 19.1 9.5 15.8 1.5 20.6 11.8 0.4 0 0.4 0.4 175 7 182 305 2 0 2 0 5.6 0.1 5.9 5.4 10/15/2004 00:30:00 12.8 1.9 17.9 8.4 15.1 1.6 19.1 10.7 0.4 0 0.4 0.4 176 7 175 305 2 0 2 0 5.5 0.1 5.9 5.4 10/15/2004 00:40:00 11.8 1.7 16.8 7.6 14 1.5 17.9 10.3 0.4 0 0.4 0.4 175 7 196 305 2 0 2 0 5.6 0.1 5.9 5.4 10/15/2004 00:50:00 12.2 2 17.9 8 14.4 1.6 18.3 9.5 0.4 0 0.4 0.4 176 7 179 305 2 0 2 0 5.6 0.1 5.9 5.4 10/15/2004 01:00:00 11.4 1.8 17.6 6.8 13.5 1.7 18.7 8.8 0.4 0 0.4 0.4 176 6 181 305 2 0 2 0 5.6 0.1 5.9 5.4 10/15/2004 01:10:00 12.5 1.7 16.8 8.4 14.5 1.5 18.3 10.7 0.4 0 0.4 0.4 178 5 179 305 2 0 2 0 5.6 0.1 6.1 5.6 10/15/2004 01:20:00 11.4 1.7 16.4 7.2 13.1 1.4 16.4 8.8 0.4 0 0.4 0.4 179 5 190 305 3 0 3 0 5.6 0.1 5.9 5.4 10/15/2004 01:30:00 12.1 1.6 16.1 8 13.4 1.3 16.8 9.9 0.4 0 0.4 0.4 180 6 179 305 3 0 2 0 5.6 0.1 6.1 5.4 10/15/2004 01:40:00 12.2 1.7 17.2 8.4 13.3 1.5 16.8 8 0.4 0 0.4 0.4 182 6 191 305 3 0 2 0 5.6 0.1 6.1 5.6 10/15/2004 01:50:00 14 1.7 17.9 9.1 14.5 1.6 18.3 9.5 0.4 0 0.4 0.4 184 5 183 305 3 0 2 0 5.6 0.1 6.1 5.4 10/15/2004 02:00:00 13.6 1.3 17.2 10.7 13.4 1.4 16.8 9.1 0.4 0 0.4 0.4 186 5 192 305 3 0 3 0 5.5 0.1 5.9 5.4 10/15/2004 02:10:00 13 1.2 15.6 9.5 12.9 1.2 16.1 9.5 0.4 0 0.4 0.4 187 5 188 305 3 0 3 0 5.5 0.1 5.9 5.4 10/15/2004 02:20:00 13.1 1.1 16.8 10.7 12.7 1.2 16.1 9.5 0.4 0 0.4 0.4 189 4 183 305 3 0 3 0 5.5 0.1 5.9 5.4 10/15/2004 02:30:00 12.7 1.2 17.2 9.5 12.4 1.3 17.6 9.1 0.4 0 0.4 0.4 189 5 193 305 3 0 3 0 5.6 0.2 5.9 5.4 10/15/2004 02:40:00 12.7 1 15.6 9.9 12.2 1.1 14.9 9.1 0.4 0 0.4 0.4 191 4 188 305 3 0 3 0 5.6 0.1 6.1 5.4 10/15/2004 02:50:00 13.5 1 16.4 10.7 12.8 1.2 16.1 9.1 0.4 0 0.4 0.4 192 4 189 305 3 0 3 0 5.6 0.1 6.1 5.6 10/15/2004 03:00:00 13.4 1 15.6 10.3 12.8 1.1 15.6 9.9 0.4 0 0.4 0.4 193 4 196 305 3 0 3 0 5.6 0.2 6.1 5.4 10/15/2004 03:10:00 12.8 0.9 14.9 10.3 12.1 1.1 14.9 8.4 0.4 0 0.4 0.4 195 3 197 305 3 0 3 0 5.6 0.2 5.9 5.4 10/15/2004 03:20:00 12.7 0.8 14.9 9.9 12 0.9 14.1 9.1 0.4 0 0.4 0.4 194 4 192 305 3 0 3 0 5.6 0.2 5.9 5.4 10/15/2004 03:30:00 12 0.7 13.7 9.9 11.5 0.8 13.7 8.8 0.4 0 0.4 0.4 198 3 203 305 3 0 3 0 5.6 0.2 6.1 5.4 10/15/2004 03:40:00 11.4 0.7 13.3 8.8 10.9 0.9 13.3 8.4 0.4 0 0.4 0.4 198 3 202 305 3 0 3 0 5.6 0.2 5.9 5.4 10/15/2004 03:50:00 10.2 0.6 11.8 8 9.7 0.6 11.5 6.8 0.4 0 0.4 0.4 197 3 194 305 3 0 3 0 5.5 0.1 5.9 5.4 10/15/2004 04:00:00 9.9 0.5 11.1 8.4 9.4 0.6 11.1 8 0.4 0 0.4 0.4 196 3 199 305 3 0 3 0 5.5 0 5.9 5.4 10/15/2004 04:10:00 9 0.7 10.7 7.2 8.5 0.8 10.7 5.7 0.4 0 0.4 0.4 192 5 194 305 3 0 3 0 5.5 0.1 5.9 5.4 10/15/2004 04:20:00 9.4 0.6 10.7 7.2 8.9 0.8 10.7 6.1 0.4 0 0.4 0.4 192 4 188 305 3 0 3 0 5.5 0 5.9 5.4 10/15/2004 04:30:00 9 0.5 10.3 7.2 8.5 0.6 9.5 6.5 0.4 0 0.4 0.4 195 3 192 305 3 0 3 0 5.4 0 5.9 5.2 10/15/2004 04:40:00 9.8 0.5 11.1 8.8 9.5 0.5 11.1 8 0.4 0 0.4 0.4 203 3 203 305 3 0 3 0 5.4 0 5.9 5.4 10/15/2004 04:50:00 9 0.7 11.1 6.8 8.5 0.8 10.3 6.1 0.4 0 0.4 0.4 207 4 208 305 3 0 3 0 5.5 0 5.9 5.4 10/15/2004 05:00:00 9.5 0.6 11.1 7.6 9.2 0.7 10.7 7.2 0.4 0 0.4 0.4 203 4 205 305 3 0 3 0 5.4 0 5.9 5.4 10/15/2004 05:10:00 9.4 0.6 11.1 7.6 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 205 3 205 305 3 0 3 0 5.3 0 5.9 5.2 10/15/2004 05:20:00 8.6 0.6 9.5 7.2 8.2 0.6 9.5 6.1 0.4 0 0.4 0.4 200 3 203 305 3 0 3 0 5.2 0 5.6 5.2 10/15/2004 05:30:00 8 0.4 9.1 6.5 7.4 0.6 8.8 5.3 0.4 0 0.4 0.4 194 3 194 305 3 0 3 0 5 0.1 5.4 4.9 10/15/2004 05:40:00 8 0.5 8.8 5.7 7.5 0.6 8.8 5.3 0.4 0 0.4 0.4 195 4 197 305 3 0 3 0 4.8 0 5.4 4.7 10/15/2004 05:50:00 8.6 1 11.5 6.5 8.1 1.1 11.1 6.1 0.4 0 0.4 0.4 199 4 201 305 3 0 3 0 4.9 0 5.4 4.7 10/15/2004 06:00:00 9.4 0.8 11.1 7.2 8.9 0.9 10.7 6.1 0.4 0 0.4 0.4 201 5 206 305 3 0 3 0 5.1 0.1 5.6 4.9 10/15/2004 06:10:00 9.8 0.8 11.8 7.6 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 205 4 213 305 3 0 3 0 5.2 0 5.6 5.2 10/15/2004 06:20:00 9.5 0.7 11.1 5.7 9.1 0.7 10.7 6.5 0.4 0 0.4 0.4 206 4 207 305 3 0 3 0 5.2 0 5.6 5.2 10/15/2004 06:30:00 9.1 0.5 10.7 7.6 8.7 0.5 9.9 7.2 0.4 0 0.4 0.4 203 3 208 305 3 0 3 0 5.2 0 5.4 4.9 10/15/2004 06:40:00 9.1 0.5 10.7 6.5 8.6 0.6 9.9 6.1 0.4 0 0.4 0.4 206 3 208 305 3 0 3 0 5.1 0 5.6 4.9 10/15/2004 06:50:00 9 0.5 10.3 7.2 8.8 0.5 10.3 7.2 0.4 0 0.4 0.4 205 3 208 305 3 0 3 0 5 0.1 5.6 4.9 10/15/2004 07:00:00 8.8 0.4 9.9 7.6 8.5 0.5 9.5 7.2 0.4 0 0.4 0.4 204 3 208 305 3 0 3 0 5 0.2 5.4 4.9 10/15/2004 07:10:00 8.5 0.4 9.5 8 8.3 0.4 9.5 7.2 0.4 0 0.4 0.4 202 2 201 305 3 0 3 0 4.9 0.1 5.4 4.9 10/15/2004 07:20:00 8.5 0.4 9.5 7.6 8.2 0.4 9.5 7.2 0.4 0 0.4 0.4 201 2 200 305 3 0 3 0 4.9 0 5.4 4.7 10/15/2004 07:30:00 8.5 0.4 9.5 7.6 8.2 0.4 9.5 6.5 0.4 0 0.4 0.4 201 2 204 305 3 0 3 0 4.9 0 5.4 4.7 10/15/2004 07:40:00 8.5 0.5 9.9 7.6 8.3 0.5 9.5 6.8 0.4 0 0.4 0.4 201 3 198 305 3 0 3 0 4.8 0 5.4 4.7 10/15/2004 07:50:00 9.2 0.4 10.3 8 8.9 0.6 10.3 6.8 0.4 0 0.4 0.4 200 3 200 305 3 0 3 0 4.9 0.1 5.4 4.7 10/15/2004 08:00:00 9.2 0.5 10.3 8 8.9 0.5 10.3 7.2 0.4 0 0.4 0.4 198 3 201 305 3 0 3 0 4.9 0 5.4 4.7 10/15/2004 08:10:00 9.1 0.5 10.7 7.6 8.8 0.5 10.3 7.2 0.4 0 0.4 0.4 197 3 200 305 3 0 3 0 4.8 0 5.4 4.7 10/15/2004 08:20:00 9.6 0.5 10.7 8.4 9.3 0.6 10.7 7.2 0.4 0 0.4 0.4 200 3 197 305 3 0 3 0 4.8 0 5.2 4.7 10/15/2004 08:30:00 9.6 0.4 10.7 8.4 9.4 0.5 10.7 8.4 0.4 0 0.4 0.4 203 2 200 305 3 0 3 0 4.9 0.1 5.4 4.7 10/15/2004 08:40:00 9.3 0.4 10.7 8.4 9 0.5 10.3 8 0.4 0 0.4 0.4 202 3 203 305 3 0 3 0 5 0.2 5.4 4.7 10/15/2004 08:50:00 8.8 0.5 10.3 5.7 8.4 0.6 9.5 5.7 0.4 0 0.4 0.4 206 5 223 305 3 0 3 0 5 0.1 5.4 4.7 10/15/2004 09:00:00 9.1 1 11.1 6.1 8.4 1 10.7 5.7 0.4 0 0.4 0.4 210 6 215 305 3 0 3 0 5.1 0.1 5.6 4.9 10/15/2004 09:10:00 9.2 0.8 11.5 6.5 8.5 0.9 11.1 6.1 0.4 0 0.4 0.4 209 6 211 305 3 0 3 0 5.2 0 5.6 5.2 10/15/2004 09:20:00 9.3 0.8 11.1 6.8 8.8 0.9 10.7 6.5 0.4 0 0.4 0.4 208 5 208 305 3 0 3 0 5.2 0 5.6 5.2 10/15/2004 09:30:00 9.6 0.6 11.1 7.2 9.2 0.8 10.7 6.1 0.4 0 0.4 0.4 206 3 208 305 3 0 3 0 5.2 0 5.6 5.2 10/15/2004 09:40:00 9.4 0.8 11.1 6.8 8.8 0.9 10.7 5.7 0.4 0 0.4 0.4 208 5 210 305 3 0 3 0 5.3 0 5.6 5.2 10/15/2004 09:50:00 10.4 1 13.3 7.2 9.7 1.2 13 5.3 0.4 0 0.4 0.4 216 8 225 305 3 0 3 0 5.3 0 5.9 5.2 10/15/2004 10:00:00 11.8 1 13.7 9.5 11.1 1 13.7 8.4 0.4 0 0.4 0.4 231 4 234 305 3 0 3 0 5.2 0.2 5.9 4.9 10/15/2004 10:10:00 10.6 0.8 12.2 8 9.8 1 11.8 7.2 0.4 0 0.4 0.4 222 5 227 305 3 0 3 0 4.9 0.1 5.4 4.9 10/15/2004 10:20:00 10.5 0.8 12.6 7.6 9.7 1 11.5 7.2 0.4 0 0.4 0.4 223 4 224 305 3 0 3 0 4.9 0.1 5.4 4.9 10/15/2004 10:30:00 10.7 1 13 8.4 10 1.2 12.6 6.1 0.4 0 0.4 0.4 227 6 225 305 3 0 3 0 4.9 0.1 5.4 4.9 10/15/2004 10:40:00 10.7 0.9 13 7.6 9.7 1.1 13 6.8 0.4 0 0.4 0.4 236 5 239 305 3 0 3 0 5 0.2 5.4 4.9 10/15/2004 10:50:00 10.2 1 13 7.2 9.6 1.1 13.3 6.8 0.4 0 0.4 0.4 239 8 249 305 3 0 3 0 5.1 0.1 5.6 4.9 10/15/2004 11:00:00 9.7 1 12.6 6.5 8.6 1.1 11.8 5.3 0.4 0 0.4 0.4 253 6 252 305 3 0 3 0 5.2 0.1 5.6 4.9 10/15/2004 11:10:00 8.6 1.5 13.7 5.3 7.5 1.1 10.3 4.6 0.4 0 0.4 0.4 254 9 269 305 3 0 3 0 5 0.1 5.6 4.9 10/15/2004 11:20:00 10 1.5 13.7 5.7 7.9 1.3 11.8 4.2 0.4 0 0.4 0.4 268 8 274 305 3 0 2 0 4.7 0 5.2 4.4 10/15/2004 11:30:00 10.3 1.3 12.6 6.1 8.7 1.3 11.8 5.3 0.4 0 0.4 0.4 276 7 269 305 2 0 2 0 4.9 0.1 5.4 4.7 10/15/2004 11:40:00 9.8 1.3 12.2 6.5 8.3 1.3 11.1 5.3 0.4 0 0.4 0.4 278 6 276 305 2 0 2 0 5 0.1 5.4 4.9 10/15/2004 11:50:00 10.4 1.2 13 6.8 9 1.3 13 5.7 0.4 0 0.4 0.4 281 7 285 305 2 0 2 0 4.9 0.1 5.6 4.9 10/15/2004 12:00:00 9.9 1.1 12.2 6.8 8.7 1.3 11.5 5.3 0.4 0 0.4 0.4 280 5 277 305 1 0 1 0 5.1 0.2 5.6 4.9 10/15/2004 12:10:00 9 1.5 12.2 5.3 8.2 1.4 11.5 4.9 0.4 0 0.4 0.4 282 7 276 305 1 0 1 0 5 0.1 5.4 4.9 10/15/2004 12:20:00 9 1 11.8 5.3 7.7 1.1 10.3 4.9 0.4 0 0.4 0.4 278 8 283 305 1 0 1 0 5 0.1 5.4 4.9 10/15/2004 12:30:00 9.4 1.3 13.3 6.5 7.5 1.3 11.1 4.2 0.4 0 0.4 0.4 269 8 264 305 1 0 1 0 5.2 0 5.6 4.9 10/15/2004 12:40:00 10.9 1.2 13.3 8 8.9 1.2 13 4.9 0.4 0 0.4 0.4 274 7 277 305 1 0 1 0 5.3 0 5.9 5.2 10/15/2004 12:50:00 9.7 1.3 13.3 6.5 8 1.3 12.2 4.9 0.4 0 0.4 0.4 274 8 280 305 0 0 0 0 5.4 0.1 5.9 5.2 10/15/2004 13:00:00 9.3 1.5 12.6 4.9 7.6 1.3 11.1 4.2 0.4 0 0.4 0.4 274 7 284 305 0 0 0 0 5.5 0.1 5.9 5.4 10/15/2004 13:10:00 9 1.2 11.8 5.7 7.1 1.1 10.3 4.6 0.4 0 0.4 0.4 266 8 275 305 0 0 0 0 5.3 0.2 5.9 5.2 10/15/2004 13:20:00 8.2 1.1 10.3 4.6 6.5 1 8.4 4.2 0.4 0 0.4 0.4 263 7 264 305 0 0 0 0 5.5 0.2 5.9 5.2 10/15/2004 13:30:00 7.9 1 10.3 5.3 6.3 0.9 8.8 3.8 0.4 0 0.4 0.4 262 6 264 305 0 0 0 0 5.3 0 5.9 5.2 10/15/2004 13:40:00 7.4 1 10.3 4.9 6 1 8.8 3.8 0.4 0 0.4 0.4 262 7 264 305 0 0 0 0 5.5 0 5.9 5.4 10/15/2004 13:50:00 7 1 9.1 3.8 5.6 0.9 8.4 3 0.4 0 0.4 0.4 263 6 259 305 0 0 0 0 5.8 0 6.1 5.6 10/15/2004 14:00:00 6.9 0.9 9.1 3 5.6 0.8 8 3.8 0.4 0 0.4 0.4 262 6 258 305 0 0 0 0 6 0 6.4 5.9 10/15/2004 14:10:00 8.5 1.1 10.7 5.7 6.9 1.1 10.3 3.8 0.4 0 0.4 0.4 261 6 267 305 0 0 0 0 6 0 6.4 5.9 10/15/2004 14:20:00 8.5 1.1 11.1 5.7 6.8 1 9.9 4.6 0.4 0 0.4 0.4 262 6 262 305 0 0 0 0 6.1 0.1 6.4 5.9 10/15/2004 14:30:00 9.6 1 11.8 6.8 7.6 1 9.9 4.2 0.4 0 0.4 0.4 263 6 268 305 0 0 0 0 6 0.1 6.7 5.9 10/15/2004 14:40:00 8.8 1 11.1 6.1 7.1 0.9 9.5 4.6 0.4 0 0.4 0.4 261 6 262 305 0 0 0 0 6.1 0.1 6.7 5.9 10/15/2004 14:50:00 8 1 10.3 5.3 6.5 0.9 9.1 4.2 0.4 0 0.4 0.4 260 7 261 305 0 0 0 0 6.3 0.1 6.9 6.1 10/15/2004 15:00:00 7.2 1 9.9 4.2 6 1 8.8 2.6 0.4 0 0.4 0.4 259 7 263 305 0 0 0 0 6.4 0.1 6.9 6.1 10/15/2004 15:10:00 7 1 9.5 4.6 6.1 1 8.8 4.2 0.4 0 0.4 0.4 255 7 251 305 0 0 0 0 6.4 0.1 6.9 6.1 10/15/2004 15:20:00 7.4 1 9.9 4.6 6.1 1 8.8 3.8 0.4 0 0.4 0.4 260 6 263 305 0 0 0 0 6.5 0.1 6.9 6.1 10/15/2004 15:30:00 6.4 1 8.8 3.4 5 0.8 8 2.6 0.4 0 0.4 0.4 265 9 261 305 0 0 0 0 6.6 0.1 7.2 6.4 10/15/2004 15:40:00 7.4 0.9 9.5 4.9 6 0.9 8.8 3.8 0.4 0 0.4 0.4 262 6 262 305 0 0 0 0 6.6 0.1 7.2 6.4 10/15/2004 15:50:00 7.3 0.9 9.5 5.3 6.5 1.2 9.1 3.8 0.4 0 0.4 0.4 254 7 261 305 0 0 0 0 6.5 0 7.2 6.1 10/15/2004 16:00:00 8.1 0.8 9.9 6.1 7.3 1.1 9.9 4.6 0.4 0 0.4 0.4 255 5 248 305 0 0 0 0 6.1 0.1 6.7 5.9 10/15/2004 16:10:00 7.3 0.7 8.8 4.9 6.5 0.7 8 4.2 0.4 0 0.4 0.4 253 5 270 305 0 0 0 0 5.8 0 6.1 5.6 10/15/2004 16:20:00 6.1 0.7 8.4 4.2 5.5 0.8 7.2 3.8 0.4 0 0.4 0.4 248 6 242 305 0 0 0 0 5.8 0.1 6.1 5.6 10/15/2004 16:30:00 5.8 0.8 7.6 3.8 5.1 0.8 7.6 3.4 0.4 0 0.4 0.4 244 6 245 305 0 0 0 0 6 0.1 6.4 5.9 10/15/2004 16:40:00 5.7 0.6 7.2 3.8 5.3 0.5 6.5 4.2 0.4 0 0.4 0.4 240 5 242 305 0 0 0 0 6 0.1 6.4 5.9 10/15/2004 16:50:00 6.2 0.5 7.6 4.6 5.7 0.6 7.2 4.2 0.4 0 0.4 0.4 240 5 241 305 0 0 0 0 6.1 0.2 6.9 5.9 10/15/2004 17:00:00 6.4 0.6 7.6 4.6 6 0.6 7.6 4.6 0.4 0 0.4 0.4 241 5 245 305 0 0 0 0 6.5 0 6.9 6.1 10/15/2004 17:10:00 6.3 0.7 8 3.8 5.9 0.6 7.6 3.8 0.4 0 0.4 0.4 240 6 240 305 0 0 0 0 6.3 0.2 6.9 6.1 10/15/2004 17:20:00 6.6 0.5 7.6 5.3 6.1 0.5 7.2 4.9 0.4 0 0.4 0.4 234 5 219 305 0 0 0 0 6.1 0.2 6.7 5.9 10/15/2004 17:30:00 6.7 0.5 8 5.3 6.3 0.5 7.6 4.9 0.4 0 0.4 0.4 232 4 232 305 0 0 0 0 6 0.1 6.4 5.9 10/15/2004 17:40:00 6.7 0.4 7.6 5.7 6.3 0.5 7.2 4.2 0.4 0 0.4 0.4 229 3 229 305 0 0 0 0 5.9 0 6.1 5.6 10/15/2004 17:50:00 6.1 0.5 7.2 4.2 5.4 0.6 6.8 3.8 0.4 0 0.4 0.4 227 4 234 305 0 0 0 0 5.8 0 6.1 5.6 10/15/2004 18:00:00 6 0.5 7.2 4.6 5.4 0.5 6.8 3.8 0.4 0 0.4 0.4 224 4 217 305 0 0 0 0 5.8 0.1 6.1 5.6 10/15/2004 18:10:00 6.5 0.5 7.6 4.9 6.1 0.6 8 4.6 0.4 0 0.4 0.4 220 4 220 305 0 0 0 0 5.6 0.1 6.1 5.4 10/15/2004 18:20:00 6.9 0.5 8 5.7 6.6 0.6 8 4.9 0.4 0 0.4 0.4 219 3 218 305 0 0 0 0 5.5 0 5.9 5.4 10/15/2004 18:30:00 7.5 0.5 8.8 6.5 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 217 3 218 305 0 0 0 0 5.3 0.2 5.9 5.2 10/15/2004 18:40:00 7.8 0.6 9.1 6.1 7.3 0.6 8.8 5.3 0.4 0 0.4 0.4 223 6 232 305 0 0 0 0 5.2 0.1 5.6 4.9 10/15/2004 18:50:00 8 0.6 9.5 6.5 7.4 0.8 9.1 4.9 0.4 0 0.4 0.4 232 5 241 305 0 0 0 0 5.4 0.1 5.9 4.9 10/15/2004 19:00:00 7.6 0.7 9.5 5.7 7 0.7 9.1 5.3 0.4 0 0.4 0.4 234 5 239 305 0 0 0 0 5.5 0.2 5.9 5.4 10/15/2004 19:10:00 7.2 0.7 8.8 5.3 6.6 0.9 9.1 3.8 0.4 0 0.4 0.4 234 5 231 305 0 0 0 0 5.5 0.1 5.9 5.4 10/15/2004 19:20:00 6.2 0.5 8 4.6 5.6 0.6 7.6 4.2 0.4 0 0.4 0.4 235 4 234 305 0 0 0 0 5.4 0 5.9 5.4 10/15/2004 19:30:00 5.6 0.5 7.2 4.6 5.3 0.5 6.8 4.2 0.4 0 0.4 0.4 233 4 231 305 0 0 0 0 5.3 0.1 5.9 4.9 10/15/2004 19:40:00 5.3 0.4 6.5 4.2 4.7 0.5 6.1 3.8 0.4 0 0.4 0.4 228 4 232 305 0 0 0 0 5 0.1 5.6 4.9 10/15/2004 19:50:00 5.2 0.4 6.1 3.8 4.7 0.4 5.7 3.4 0.4 0 0.4 0.4 228 4 228 305 0 0 0 0 4.9 0 5.6 4.9 10/15/2004 20:00:00 5.5 0.5 6.8 3.8 4.9 0.5 6.5 3.4 0.4 0 0.4 0.4 227 4 232 305 0 0 0 0 4.9 0 5.4 4.9 10/15/2004 20:10:00 6.5 0.4 7.6 5.3 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 223 4 227 305 0 0 0 0 4.9 0 5.4 4.9 10/15/2004 20:20:00 6.8 0.6 8.4 4.9 6.4 0.6 7.6 4.9 0.4 0 0.4 0.4 221 4 231 305 0 0 0 0 5 0.1 5.4 4.9 10/15/2004 20:30:00 7.3 0.6 8.8 5.7 6.6 0.6 8.4 5.3 0.4 0 0.4 0.4 222 4 223 305 0 0 0 0 5 0.1 5.4 4.9 10/15/2004 20:40:00 6.9 0.5 8.4 5.7 6.4 0.6 7.6 4.9 0.4 0 0.4 0.4 221 4 224 305 1 0 1 0 5.1 0.1 5.6 4.9 10/15/2004 20:50:00 7 0.5 8.8 5.7 6.6 0.5 8.4 4.9 0.4 0 0.4 0.4 220 4 221 305 1 0 0 0 5 0.1 5.4 4.9 10/15/2004 21:00:00 7.3 0.6 8.8 5.7 6.7 0.6 8.8 4.9 0.4 0 0.4 0.4 221 4 217 305 1 0 1 0 5.1 0 5.6 4.9 10/15/2004 21:10:00 8.1 0.6 9.9 6.1 7.3 0.7 9.1 5.3 0.4 0 0.4 0.4 222 4 224 305 1 0 1 0 5.2 0 5.6 4.9 10/15/2004 21:20:00 8 0.5 9.1 6.5 7.3 0.6 9.1 5.7 0.4 0 0.4 0.4 221 4 226 305 1 0 1 0 5.2 0 5.6 4.9 10/15/2004 21:30:00 7.9 0.5 9.9 6.5 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 220 4 228 305 1 0 1 0 5.2 0.1 5.6 5.2 10/15/2004 21:40:00 8.1 0.6 9.5 6.5 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 222 4 223 305 1 0 1 0 5.2 0 5.6 5.2 10/15/2004 21:50:00 8.5 0.6 10.3 6.5 7.7 0.7 9.1 5.7 0.4 0 0.4 0.4 221 4 228 305 1 0 1 0 5.4 0.1 5.9 5.2 10/15/2004 22:00:00 8.3 0.7 10.7 6.5 7.9 0.8 10.7 6.1 0.4 0 0.4 0.4 219 4 217 305 1 0 1 0 5.5 0.1 5.9 5.4 10/15/2004 22:10:00 8.3 0.6 10.3 6.5 7.6 0.8 10.3 5.7 0.4 0 0.4 0.4 222 4 218 305 1 0 1 0 5.4 0 5.9 5.4 10/15/2004 22:20:00 8.5 0.7 10.3 5.7 7.8 0.9 10.3 4.9 0.4 0 0.4 0.4 227 5 235 305 1 0 1 0 5.5 0.1 5.9 5.4 10/15/2004 22:30:00 8.2 0.6 9.5 6.5 7.7 0.6 9.1 5.7 0.4 0 0.4 0.4 229 4 231 305 1 0 1 0 5.5 0 5.9 5.4 10/15/2004 22:40:00 8.2 0.6 9.5 6.5 7.6 0.6 9.1 5.3 0.4 0 0.4 0.4 232 4 237 305 1 0 1 0 5.5 0.1 5.9 5.4 10/15/2004 22:50:00 7.8 0.7 9.5 6.1 7.1 0.7 9.1 5.3 0.4 0 0.4 0.4 238 5 236 305 1 0 1 0 5.5 0 5.9 5.4 10/15/2004 23:00:00 8.3 0.7 9.9 6.1 7.6 0.7 9.5 5.7 0.4 0 0.4 0.4 239 5 242 305 1 0 1 0 5.5 0.1 5.9 5.4 10/15/2004 23:10:00 8.3 0.7 9.9 6.5 7.5 0.7 9.5 6.1 0.4 0 0.4 0.4 239 5 239 305 1 0 1 0 5.5 0.1 5.9 5.4 10/15/2004 23:20:00 8.6 0.7 10.3 6.5 7.8 0.8 9.9 6.1 0.4 0 0.4 0.4 239 5 242 305 1 0 1 0 5.5 0.1 5.9 5.4 10/15/2004 23:30:00 8.1 0.7 9.5 5.7 7.3 0.8 9.1 4.6 0.4 0 0.4 0.4 238 5 242 305 1 0 1 0 5.3 0 5.9 5.2 10/15/2004 23:40:00 7.6 0.6 9.1 5.7 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 237 4 238 305 1 0 1 0 5.2 0 5.6 5.2 10/15/2004 23:50:00 7.2 0.6 8.8 5.3 6.5 0.6 8.4 4.9 0.4 0 0.4 0.4 239 4 245 305 1 0 1 0 5.2 0 5.6 4.9 10/16/2004 00:00:00 7.6 0.6 8.8 6.1 6.8 0.6 8.4 5.3 0.4 0 0.4 0.4 241 4 242 305 1 0 1 0 5.2 0 5.6 4.9 10/16/2004 00:10:00 7.3 0.7 9.5 5.3 6.6 0.7 8.8 4.6 0.4 0 0.4 0.4 245 5 257 305 1 0 1 0 5.3 0.1 5.6 5.2 10/16/2004 00:20:00 6.9 0.7 8.4 4.9 6.2 0.7 8 4.2 0.4 0 0.4 0.4 249 6 250 305 1 0 1 0 5.2 0 5.6 5.2 10/16/2004 00:30:00 7.1 0.6 8.8 5.3 6.2 0.8 8 4.2 0.4 0 0.4 0.4 252 6 246 305 1 0 1 0 5.2 0 5.6 5.2 10/16/2004 00:40:00 6.7 0.7 8 4.9 6 0.7 8 3.8 0.4 0 0.4 0.4 250 5 246 305 1 0 1 0 5.2 0.1 5.6 5.2 10/16/2004 00:50:00 6.5 0.6 8 4.6 5.9 0.7 7.6 4.2 0.4 0 0.4 0.4 251 6 242 305 1 0 1 0 5.2 0 5.6 4.9 10/16/2004 01:00:00 6 0.5 7.2 4.6 5.3 0.6 6.8 3.8 0.4 0 0.4 0.4 252 5 254 305 1 0 1 0 5.2 0.1 5.6 4.9 10/16/2004 01:10:00 5.4 0.5 6.8 4.2 4.9 0.6 6.8 3.4 0.4 0 0.4 0.4 250 5 255 305 1 0 1 0 5 0.2 5.6 4.9 10/16/2004 01:20:00 6.2 0.6 8 4.6 5.5 0.6 6.8 3.4 0.4 0 0.4 0.4 241 5 242 305 1 0 1 0 5 0.2 5.4 4.9 10/16/2004 01:30:00 6.4 0.5 7.6 4.9 5.7 0.5 7.2 4.6 0.4 0 0.4 0.4 235 4 232 305 1 0 1 0 5 0.1 5.4 4.9 10/16/2004 01:40:00 6.6 0.5 8 5.3 5.8 0.6 7.2 4.2 0.4 0 0.4 0.4 235 4 238 305 1 0 1 0 5 0.2 5.6 4.9 10/16/2004 01:50:00 6.8 0.5 8.4 5.3 6.1 0.6 8 4.2 0.4 0 0.4 0.4 238 5 239 305 1 0 1 0 4.9 0.1 5.4 4.9 10/16/2004 02:00:00 6.8 0.5 8 5.3 6.1 0.6 7.6 4.2 0.4 0 0.4 0.4 236 4 238 305 1 0 1 0 4.9 0.1 5.4 4.9 10/16/2004 02:10:00 7 0.5 8.4 5.3 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 234 3 234 305 1 0 1 0 5 0.2 5.6 4.9 10/16/2004 02:20:00 7.1 0.5 8 5.3 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 234 4 229 305 1 0 1 0 5 0.2 5.6 4.9 10/16/2004 02:30:00 7.2 0.6 8.8 5.7 6.5 0.6 8.4 5.3 0.4 0 0.4 0.4 232 4 234 305 1 0 2 0 5.1 0.1 5.6 4.9 10/16/2004 02:40:00 7.6 0.5 8.8 6.1 7.1 0.6 8.4 4.9 0.4 0 0.4 0.4 231 3 234 305 2 0 2 0 5.2 0.1 5.6 4.9 10/16/2004 02:50:00 7.5 0.5 8.8 5.7 6.9 0.6 8.4 4.9 0.4 0 0.4 0.4 228 3 227 305 2 0 1 0 5 0.1 5.6 4.9 10/16/2004 03:00:00 7.1 0.5 8.4 5.3 6.4 0.7 8 4.6 0.4 0 0.4 0.4 227 4 228 305 2 0 1 0 5 0.2 5.4 4.9 10/16/2004 03:10:00 6.6 0.5 8 4.9 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 223 4 229 305 2 0 1 0 4.9 0.1 5.4 4.9 10/16/2004 03:20:00 6.8 1 8.8 4.6 6.3 0.9 8 4.2 0.4 0 0.4 0.4 224 5 221 305 2 0 2 0 4.9 0 5.4 4.9 10/16/2004 03:30:00 7.2 0.6 8.4 5.3 6.6 0.6 8 4.9 0.4 0 0.4 0.4 226 4 228 305 2 0 2 0 4.9 0 5.4 4.9 10/16/2004 03:40:00 6.3 0.5 8 4.9 5.8 0.6 7.2 4.2 0.4 0 0.4 0.4 222 4 226 305 2 0 2 0 4.8 0 5.4 4.9 10/16/2004 03:50:00 6.5 0.5 7.6 4.9 6 0.6 7.2 4.6 0.4 0 0.4 0.4 222 4 224 305 2 0 2 0 5 0.1 5.4 4.9 10/16/2004 04:00:00 5.9 0.4 6.8 4.6 5.5 0.5 6.5 3.8 0.4 0 0.4 0.4 219 5 224 305 2 0 2 0 5.2 0.2 5.6 4.9 10/16/2004 04:10:00 5.9 0.5 7.2 4.2 5.4 0.6 6.5 3.4 0.4 0 0.4 0.4 211 5 220 305 2 0 2 0 5 0.2 5.6 4.9 10/16/2004 04:20:00 7.1 0.7 8 4.9 6.6 0.8 8 4.2 0.4 0 0.4 0.4 216 3 216 305 2 0 2 0 5.2 0.2 5.9 4.9 10/16/2004 04:30:00 6.8 0.5 8 4.9 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 212 5 214 305 2 0 2 0 5.2 0 5.6 4.9 10/16/2004 04:40:00 7.1 0.4 8 6.1 7 0.4 8 5.7 0.4 0 0.4 0.4 206 3 209 305 2 0 2 0 5.1 0.2 5.6 4.9 10/16/2004 04:50:00 6.4 0.3 7.6 5.7 6.3 0.4 7.2 4.9 0.4 0 0.4 0.4 206 2 206 305 2 0 2 0 4.9 0.1 5.6 4.9 10/16/2004 05:00:00 6.3 0.3 6.8 5.3 6.1 0.3 6.8 4.9 0.4 0 0.4 0.4 205 2 204 305 2 0 2 0 4.9 0.1 5.4 4.9 10/16/2004 05:10:00 6.6 0.5 8 5.3 6.3 0.5 7.6 4.9 0.4 0 0.4 0.4 209 4 218 305 2 0 2 0 4.8 0 5.4 4.7 10/16/2004 05:20:00 7.5 0.5 8.8 5.7 6.9 0.7 8.4 4.9 0.4 0 0.4 0.4 212 5 214 305 2 0 2 0 5 0.1 5.6 4.9 10/16/2004 05:30:00 7.4 0.6 8.8 5.3 6.8 0.6 8 4.9 0.4 0 0.4 0.4 210 5 211 305 2 0 2 0 5.2 0.1 5.9 4.9 10/16/2004 05:40:00 7.6 0.4 8.8 6.5 7.5 0.4 8.4 6.1 0.4 0 0.4 0.4 205 3 205 305 2 0 2 0 5.2 0.1 5.6 4.9 10/16/2004 05:50:00 8.3 0.4 9.1 6.8 8.1 0.5 9.1 6.8 0.4 0 0.4 0.4 202 2 201 305 2 0 2 0 5.2 0.1 5.6 4.9 10/16/2004 06:00:00 8.3 0.5 9.5 6.8 8.2 0.5 9.1 6.8 0.4 0 0.4 0.4 203 3 202 305 2 0 2 0 5.2 0 5.6 5.2 10/16/2004 06:10:00 7.8 0.3 8.8 6.8 7.7 0.4 8.8 6.5 0.4 0 0.4 0.4 203 3 208 305 2 0 2 0 5.3 0 5.9 5.2 10/16/2004 06:20:00 7.5 0.5 9.1 6.5 7.4 0.5 8.8 5.7 0.4 0 0.4 0.4 198 3 200 305 2 0 2 0 5.2 0.1 5.6 4.9 10/16/2004 06:30:00 6.5 0.5 7.6 5.7 6.5 0.5 8 4.6 0.4 0 0.4 0.4 195 4 194 305 2 0 2 0 5.2 0.1 5.6 5.2 10/16/2004 06:40:00 6.1 0.5 7.2 3.8 6.1 0.6 7.6 3.8 0.4 0 0.4 0.4 196 6 192 305 2 0 2 0 5.2 0.1 5.6 4.9 10/16/2004 06:50:00 6.2 0.3 6.8 4.6 6 0.4 6.8 4.2 0.4 0 0.4 0.4 206 3 200 305 2 0 2 0 5.2 0.2 5.6 4.9 10/16/2004 07:00:00 6.4 0.3 7.6 5.7 6.1 0.3 6.8 4.9 0.4 0 0.4 0.4 205 2 203 305 2 0 2 0 4.9 0.1 5.4 4.7 10/16/2004 07:10:00 7.2 0.3 8.4 6.5 7 0.4 8 5.3 0.4 0 0.4 0.4 201 2 202 305 2 0 2 0 5 0.2 5.6 4.7 10/16/2004 07:20:00 6.7 0.4 7.6 5.7 6.4 0.5 7.2 4.6 0.4 0 0.4 0.4 199 3 202 305 2 0 2 0 5 0.1 5.6 4.7 10/16/2004 07:30:00 7.5 0.6 9.1 6.1 7.3 0.7 9.5 5.3 0.4 0 0.4 0.4 202 3 205 305 2 0 2 0 4.9 0.1 5.4 4.7 10/16/2004 07:40:00 8.8 0.6 9.9 6.1 8.2 0.8 10.3 5.7 0.4 0 0.4 0.4 208 4 212 305 2 0 2 0 5 0.2 5.6 4.9 10/16/2004 07:50:00 7.7 0.9 9.5 4.9 7.2 0.9 9.1 4.6 0.4 0 0.4 0.4 209 5 208 305 2 0 2 0 5.1 0 5.6 4.9 10/16/2004 08:00:00 5.9 0.5 7.6 4.2 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 208 4 208 305 2 0 2 0 5.1 0.2 5.6 4.9 10/16/2004 08:10:00 7.1 0.7 8.8 5.7 7 0.7 8.4 5.3 0.4 0 0.4 0.4 206 2 204 305 2 0 2 0 4.9 0.1 5.4 4.9 10/16/2004 08:20:00 8 0.5 9.5 5.7 7.9 0.6 9.1 5.3 0.4 0 0.4 0.4 206 3 210 305 2 0 2 0 5 0.2 5.6 4.9 10/16/2004 08:30:00 7.1 0.4 8 6.1 7 0.4 8.4 5.7 0.4 0 0.4 0.4 203 3 207 305 3 0 2 0 5.2 0.1 5.6 4.9 10/16/2004 08:40:00 7.2 0.4 8.4 6.1 7 0.5 8 5.3 0.4 0 0.4 0.4 198 3 199 305 3 0 2 0 5 0.2 5.6 4.9 10/16/2004 08:50:00 7.4 0.6 8.8 6.1 7.1 0.8 8.8 4.6 0.4 0 0.4 0.4 197 3 200 305 3 0 2 0 4.9 0.1 5.4 4.9 10/16/2004 09:00:00 6.3 0.4 7.2 4.9 6.3 0.5 7.6 4.6 0.4 0 0.4 0.4 191 4 192 305 3 0 2 0 4.8 0 5.4 4.7 10/16/2004 09:10:00 6.9 0.7 8 4.6 7.3 0.6 8.4 5.3 0.4 0 0.4 0.4 185 3 188 305 3 0 3 0 4.7 0 5.2 4.7 10/16/2004 09:20:00 7.4 0.6 8.4 3.8 7.8 0.5 8.8 5.7 0.4 0 0.4 0.4 186 4 187 305 3 0 3 0 4.8 0 5.4 4.7 10/16/2004 09:30:00 8.2 0.2 8.8 7.6 8.4 0.3 9.1 7.2 0.4 0 0.4 0.4 188 2 192 305 3 0 2 0 4.7 0 5.2 4.7 10/16/2004 09:40:00 8.4 0.3 9.1 7.6 8.6 0.4 9.5 7.6 0.4 0 0.4 0.4 188 2 192 305 3 0 2 0 4.8 0 5.4 4.7 10/16/2004 09:50:00 8.6 0.3 9.1 7.2 9 0.3 9.9 8 0.4 0 0.4 0.4 188 3 190 305 3 0 3 0 4.8 0 5.4 4.7 10/16/2004 10:00:00 8.1 0.5 9.5 6.1 8.7 0.5 9.9 6.8 0.4 0 0.4 0.4 185 3 184 305 3 0 3 0 5 0.2 5.4 4.9 10/16/2004 10:10:00 7.3 0.4 8.4 6.1 7.8 0.4 8.8 6.1 0.4 0 0.4 0.4 185 3 194 305 3 0 3 0 4.9 0.1 5.4 4.7 10/16/2004 10:20:00 7.5 0.4 8.4 6.1 7.8 0.5 8.8 6.5 0.4 0 0.4 0.4 186 3 187 305 3 0 2 0 4.9 0.1 5.4 4.7 10/16/2004 10:30:00 7 0.4 8 5.7 7 0.5 8.4 5.7 0.4 0 0.4 0.4 187 3 190 305 3 0 2 0 4.8 0 5.4 4.7 10/16/2004 10:40:00 7.1 0.5 8.4 5.7 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 185 3 183 305 3 0 2 0 4.9 0.1 5.4 4.7 10/16/2004 10:50:00 7.2 0.5 8.4 6.1 7.1 0.5 8 5.7 0.4 0 0.4 0.4 188 3 188 305 2 0 3 0 4.9 0.1 5.4 4.7 10/16/2004 11:00:00 7.1 0.4 8 5.7 7 0.4 8.4 5.7 0.4 0 0.4 0.4 187 3 187 305 2 0 2 0 5 0.2 5.6 4.9 10/16/2004 11:10:00 6.9 0.7 8.4 3.8 7 0.6 8.4 5.3 0.4 0 0.4 0.4 186 4 192 305 2 0 2 0 5.2 0 5.6 4.9 10/16/2004 11:20:00 7.4 0.5 9.1 5.3 7.3 0.6 9.1 5.3 0.4 0 0.4 0.4 187 3 189 305 2 0 2 0 5.3 0.1 5.6 5.2 10/16/2004 11:30:00 7.5 0.5 8.8 6.1 7.3 0.5 8.8 5.7 0.4 0 0.4 0.4 187 3 192 305 2 0 2 0 5.5 0.1 5.9 5.2 10/16/2004 11:40:00 8.7 0.5 9.9 6.8 8.2 0.7 9.9 6.1 0.4 0 0.4 0.4 192 3 189 305 2 0 2 0 5.5 0.1 5.9 5.4 10/16/2004 11:50:00 8 0.6 9.9 6.5 7.6 0.7 9.5 5.3 0.4 0 0.4 0.4 191 3 192 305 2 0 2 0 5.5 0.1 5.9 5.4 10/16/2004 12:00:00 8.1 0.6 9.9 6.8 7.8 0.7 9.5 5.3 0.4 0 0.4 0.4 190 3 190 305 2 0 2 0 5.5 0.2 5.9 5.4 10/16/2004 12:10:00 7.8 0.6 9.1 5.3 7.5 0.6 8.8 5.3 0.4 0 0.4 0.4 190 3 193 305 2 0 2 0 5.6 0.2 5.9 5.4 10/16/2004 12:20:00 8.3 0.6 9.5 6.1 7.9 0.6 9.1 5.7 0.4 0 0.4 0.4 192 3 194 305 2 0 2 0 5.6 0.1 6.1 5.6 10/16/2004 12:30:00 8.4 0.5 9.5 7.2 7.9 0.6 9.5 6.1 0.4 0 0.4 0.4 195 3 192 305 1 0 1 0 5.8 0 6.4 5.6 10/16/2004 12:40:00 8.7 0.5 10.3 7.6 8.4 0.6 10.3 6.1 0.4 0 0.4 0.4 198 3 194 305 1 0 1 0 6 0 6.4 5.9 10/16/2004 12:50:00 8.8 0.5 9.9 7.6 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 196 3 201 305 1 0 1 0 5.8 0 6.1 5.6 10/16/2004 13:00:00 9 0.5 10.7 7.6 8.6 0.7 10.3 6.1 0.4 0 0.4 0.4 194 3 194 305 1 0 1 0 5.8 0 6.1 5.6 10/16/2004 13:10:00 9 0.6 10.7 7.6 8.5 0.9 10.7 5.7 0.4 0 0.4 0.4 192 4 189 305 1 0 1 0 5.8 0 6.1 5.6 10/16/2004 13:20:00 9.4 0.8 11.5 6.8 9 1 11.5 6.5 0.4 0 0.4 0.4 192 3 191 305 1 0 1 0 5.8 0 6.1 5.6 10/16/2004 13:30:00 9.1 0.7 11.1 6.8 8.6 0.8 11.1 6.5 0.4 0 0.4 0.4 193 3 193 305 1 0 1 0 5.9 0 6.1 5.9 10/16/2004 13:40:00 8.9 0.8 11.1 6.8 8.6 0.9 11.1 6.1 0.4 0 0.4 0.4 194 3 190 305 1 0 1 0 5.9 0 6.1 5.9 10/16/2004 13:50:00 9.1 0.8 11.5 7.2 8.7 1 11.5 5.7 0.4 0 0.4 0.4 195 3 198 305 1 0 1 0 6 0 6.1 5.6 10/16/2004 14:00:00 9.2 0.8 11.5 6.5 8.8 0.9 11.1 6.1 0.4 0 0.4 0.4 195 3 202 305 0 0 1 0 5.8 0 6.1 5.6 10/16/2004 14:10:00 9.5 0.7 11.5 7.6 9 0.8 11.5 6.8 0.4 0 0.4 0.4 196 3 200 305 1 0 1 0 5.8 0 6.1 5.6 10/16/2004 14:20:00 9.6 0.8 12.2 7.6 9.2 1 12.2 6.1 0.4 0 0.4 0.4 195 4 199 305 1 0 0 0 5.8 0 6.1 5.6 10/16/2004 14:30:00 9.9 0.6 11.8 8 9.4 0.8 11.1 6.5 0.4 0 0.4 0.4 195 3 189 305 1 0 1 0 5.8 0 6.1 5.6 10/16/2004 14:40:00 9.8 0.6 11.1 8.4 9.4 0.8 11.1 7.2 0.4 0 0.4 0.4 197 3 194 305 0 0 0 0 5.9 0 6.4 5.9 10/16/2004 14:50:00 9.8 0.6 11.5 8 9.3 0.8 11.5 6.8 0.4 0 0.4 0.4 197 3 196 305 0 0 0 0 5.9 0 6.1 5.9 10/16/2004 15:00:00 10 0.5 11.5 8.8 9.5 0.7 11.1 7.2 0.4 0 0.4 0.4 196 3 198 305 0 0 0 0 6 0 6.4 5.9 10/16/2004 15:10:00 9.7 0.7 11.5 6.8 9.3 0.8 11.1 6.5 0.4 0 0.4 0.4 196 3 194 305 0 0 0 0 5.9 0 6.1 5.6 10/16/2004 15:20:00 9.8 0.6 11.5 8 9.4 0.7 11.1 6.8 0.4 0 0.4 0.4 197 3 196 305 0 0 0 0 5.9 0 6.4 5.6 10/16/2004 15:30:00 10.5 0.6 11.8 8.4 10.1 0.8 11.8 7.6 0.4 0 0.4 0.4 197 3 198 305 0 0 0 0 5.7 0 6.1 5.6 10/16/2004 15:40:00 10.6 0.7 12.2 9.1 10.3 0.8 12.2 7.6 0.4 0 0.4 0.4 201 3 198 305 0 0 0 0 5.6 0 5.9 5.6 10/16/2004 15:50:00 10.3 0.6 12.2 8.8 10 0.6 11.8 8 0.4 0 0.4 0.4 200 3 201 305 0 0 0 0 5.7 0 5.9 5.6 10/16/2004 16:00:00 10.2 0.6 11.8 8.8 9.9 0.6 11.5 8.4 0.4 0 0.4 0.4 199 3 200 305 0 0 0 0 5.6 0 6.1 5.6 10/16/2004 16:10:00 10.2 0.6 11.5 8.4 9.7 0.7 11.5 7.2 0.4 0 0.4 0.4 197 4 205 305 0 0 0 0 5.6 0 5.9 5.6 10/16/2004 16:20:00 9.7 0.6 11.5 7.6 9.3 0.7 11.1 6.8 0.4 0 0.4 0.4 196 4 193 305 0 0 0 0 5.6 0 5.9 5.6 10/16/2004 16:30:00 9.6 0.6 11.5 7.2 9.2 0.7 10.7 6.8 0.4 0 0.4 0.4 196 3 199 305 0 0 0 0 5.6 0 6.1 5.6 10/16/2004 16:40:00 8.9 0.6 11.1 6.8 8.5 0.8 10.7 6.1 0.4 0 0.4 0.4 191 4 191 305 0 0 0 0 5.6 0.1 5.9 5.4 10/16/2004 16:50:00 8.9 0.6 10.3 6.8 8.7 0.8 10.3 6.1 0.4 0 0.4 0.4 188 4 189 305 0 0 0 0 5.5 0.1 6.1 5.4 10/16/2004 17:00:00 8.3 0.6 9.9 6.5 8.3 0.7 9.9 6.1 0.4 0 0.4 0.4 187 3 188 305 0 0 0 0 5.5 0.1 5.9 5.4 10/16/2004 17:10:00 8.1 0.6 9.9 6.8 7.9 0.7 9.5 5.7 0.4 0 0.4 0.4 188 3 189 305 0 0 0 0 5.4 0 5.9 5.4 10/16/2004 17:20:00 7.9 0.7 9.9 5.3 7.8 0.6 9.9 6.1 0.4 0 0.4 0.4 187 4 192 305 0 0 0 0 5.4 0 5.9 5.2 10/16/2004 17:30:00 7.4 1.5 9.9 3.4 7.7 1.1 10.3 4.2 0.4 0 0.4 0.4 183 5 183 305 0 0 0 0 5.3 0 5.6 5.2 10/16/2004 17:40:00 7.1 0.8 9.1 4.6 7.4 0.8 9.5 5.3 0.4 0 0.4 0.4 184 4 187 305 0 0 0 0 5.4 0 5.9 5.4 10/16/2004 17:50:00 6.4 0.7 8 4.2 6.4 0.7 8 4.6 0.4 0 0.4 0.4 185 3 187 305 0 0 0 0 5.2 0 5.6 5.2 10/16/2004 18:00:00 6.8 0.5 8.4 5.3 6.7 0.5 8 5.3 0.4 0 0.4 0.4 186 3 189 305 0 0 0 0 5.2 0 5.6 4.9 10/16/2004 18:10:00 5.1 0.9 7.2 3 5.8 0.6 7.6 4.2 0.4 0 0.4 0.4 179 6 178 305 0 0 0 0 5.1 0 5.6 4.9 10/16/2004 18:20:00 6 1 8.4 3 6.9 0.8 8.8 4.9 0.4 0 0.4 0.4 180 5 186 305 0 0 0 0 5.3 0 5.6 5.2 10/16/2004 18:30:00 6.2 1 8.4 3.8 7.3 0.9 9.5 5.3 0.4 0 0.4 0.4 178 7 183 305 0 0 0 0 5.2 0.1 5.6 4.9 10/16/2004 18:40:00 6.3 1 9.5 3.8 8.4 0.7 10.3 6.5 0.4 0 0.4 0.4 174 6 184 305 0 0 0 0 5.2 0 5.6 5.2 10/16/2004 18:50:00 6.8 1.2 9.9 4.2 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 177 6 177 305 0 0 0 0 5.3 0 5.9 5.2 10/16/2004 19:00:00 7.1 1.4 9.5 4.2 8.2 0.9 9.9 5.7 0.4 0 0.4 0.4 180 5 186 305 0 0 0 0 5.3 0 5.6 5.2 10/16/2004 19:10:00 8.2 0.9 9.9 4.9 8.8 0.6 10.3 6.8 0.4 0 0.4 0.4 182 4 183 305 0 0 0 0 5.3 0 5.6 5.2 10/16/2004 19:20:00 6.9 1.2 9.5 4.2 8.4 1 10.7 5.3 0.4 0 0.4 0.4 178 6 181 305 0 0 0 0 5.4 0 5.9 5.2 10/16/2004 19:30:00 7 1.2 9.9 4.2 8.6 0.8 11.1 6.5 0.4 0 0.4 0.4 178 6 186 305 0 0 0 0 5.5 0.1 5.9 5.4 10/16/2004 19:40:00 7.2 1.5 10.3 3.8 8.2 0.9 10.7 5.7 0.4 0 0.4 0.4 179 6 185 305 0 0 0 0 5.6 0.2 5.9 5.4 10/16/2004 19:50:00 7.5 1.5 10.7 4.2 8.6 1 10.7 5.7 0.4 0 0.4 0.4 179 6 181 305 0 0 0 0 5.6 0.1 5.9 5.4 10/16/2004 20:00:00 6.5 1.1 9.1 3.8 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 177 6 179 305 0 0 0 0 5.6 0.2 5.9 5.4 10/16/2004 20:10:00 6.9 1.2 9.9 4.2 8.5 0.7 11.1 6.5 0.4 0 0.4 0.4 176 6 182 305 0 0 0 0 5.8 0 6.1 5.6 10/16/2004 20:20:00 6.5 1.1 10.7 3.8 7.9 1.1 10.7 5.3 0.4 0 0.4 0.4 174 8 183 305 0 0 0 0 5.5 0.4 6.4 4.9 10/16/2004 20:30:00 6.8 1.2 10.3 3.8 8.9 1.1 12.2 6.1 0.4 0 0.4 0.4 175 6 188 305 0 0 0 0 5.6 0.1 6.1 5.2 10/16/2004 20:40:00 7.1 1.1 9.9 4.2 8.8 1.1 12.2 5.3 0.4 0 0.4 0.4 170 7 182 305 0 0 0 0 5.5 0.2 6.1 5.2 10/16/2004 20:50:00 6.4 1 9.1 3.8 7.4 0.9 10.7 5.7 0.4 0 0.4 0.4 165 6 171 305 0 0 0 0 4.9 0.1 5.4 4.7 10/16/2004 21:00:00 6 1 8.8 3.8 7 0.9 10.3 4.9 0.4 0 0.4 0.4 167 8 173 305 0 0 0 0 4.7 0.1 5.2 4.4 10/16/2004 21:10:00 6.3 1 9.5 4.6 7.5 1.1 10.3 5.3 0.4 0 0.4 0.4 168 8 163 305 0 0 0 0 4.7 0.1 5.4 4.4 10/16/2004 21:20:00 5.9 1 9.1 3.4 6.7 1 9.9 4.9 0.4 0 0.4 0.4 166 9 158 305 0 0 0 0 4.8 0.1 5.4 4.4 10/16/2004 21:30:00 5.9 0.7 8 3.4 5.9 0.6 7.6 4.2 0.4 0 0.4 0.4 153 7 154 305 0 0 0 0 4.4 0.1 4.9 4.2 10/16/2004 21:40:00 6 0.8 9.1 4.2 5.9 0.7 8.4 4.2 0.4 0 0.4 0.4 149 7 151 305 0 0 0 0 4.2 0 4.7 4.2 10/16/2004 21:50:00 6.6 0.9 8.4 4.6 6.2 0.8 8 4.2 0.4 0 0.4 0.4 151 6 153 305 0 0 0 0 4.2 0 4.7 4.2 10/16/2004 22:00:00 6.3 0.7 8 4.6 5.9 0.6 8 4.6 0.4 0 0.4 0.4 150 6 156 305 0 0 0 0 4.4 0 4.9 4.2 10/16/2004 22:10:00 6.5 0.7 7.6 4.9 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 153 6 146 305 0 0 0 0 4.4 0.1 4.9 4.4 10/16/2004 22:20:00 7 1 9.1 4.6 6.6 1 8.8 4.6 0.4 0 0.4 0.4 150 6 154 305 1 0 1 0 4.4 0.1 4.9 4.4 10/16/2004 22:30:00 7.4 0.7 9.1 5.7 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 146 6 147 305 1 0 1 0 4.5 0 4.9 4.4 10/16/2004 22:40:00 7.1 0.7 8.8 4.9 6.9 0.6 8.8 5.3 0.4 0 0.4 0.4 144 7 143 305 1 0 1 0 4.5 0.1 4.9 4.4 10/16/2004 22:50:00 8.6 0.9 10.7 6.1 8.4 0.9 10.7 6.1 0.4 0 0.4 0.4 142 7 140 305 1 0 1 0 4.5 0 4.9 4.4 10/16/2004 23:00:00 8.3 1.1 11.5 5.7 8.1 1 11.1 5.3 0.4 0 0.4 0.4 147 8 144 305 1 0 1 0 4.5 0.1 4.9 4.4 10/16/2004 23:10:00 8.4 0.9 10.3 6.5 8.2 0.9 10.7 6.5 0.4 0 0.4 0.4 144 6 148 305 1 0 1 0 4.4 0.1 4.9 4.4 10/16/2004 23:20:00 8.9 0.9 11.1 5.7 8.5 0.9 10.3 5.7 0.4 0 0.4 0.4 149 6 154 305 1 0 1 0 4.4 0 4.9 4.4 10/16/2004 23:30:00 8 0.9 10.3 5.3 7.9 0.8 9.9 6.1 0.4 0 0.4 0.4 150 8 149 305 1 0 1 0 4.4 0 4.9 4.4 10/16/2004 23:40:00 8.4 1 10.7 6.1 8.1 0.9 9.9 5.7 0.4 0 0.4 0.4 151 6 156 305 1 0 1 0 4.4 0 4.9 4.4 10/16/2004 23:50:00 7.6 1 10.3 5.3 7.4 0.8 9.9 5.3 0.4 0 0.4 0.4 153 7 174 305 1 0 1 0 4.5 0.2 4.9 4.4 10/17/2004 00:00:00 8.3 1 10.7 5.3 8 0.8 9.9 5.7 0.4 0 0.4 0.4 152 6 148 305 1 0 1 0 4.4 0 4.9 4.4 10/17/2004 00:10:00 8.4 0.7 9.9 6.1 8 0.7 9.9 6.1 0.4 0 0.4 0.4 152 6 150 305 1 0 1 0 4.5 0 4.9 4.4 10/17/2004 00:20:00 8.6 0.8 10.7 6.1 8.1 0.7 9.9 6.5 0.4 0 0.4 0.4 151 5 147 305 1 0 1 0 4.5 0 4.9 4.4 10/17/2004 00:30:00 8.3 0.9 11.1 6.1 7.9 0.8 10.3 6.1 0.4 0 0.4 0.4 150 6 156 305 1 0 1 0 4.4 0 4.9 4.4 10/17/2004 00:40:00 8.8 0.8 10.7 6.5 8.3 0.7 10.3 6.5 0.4 0 0.4 0.4 151 5 154 305 1 0 1 0 4.5 0 4.9 4.4 10/17/2004 00:50:00 7.8 0.8 9.9 4.9 7.4 0.8 9.9 5.3 0.4 0 0.4 0.4 150 7 151 305 1 0 1 0 4.5 0 4.9 4.4 10/17/2004 01:00:00 7.5 0.8 9.1 4.9 7.1 0.8 9.5 5.3 0.4 0 0.4 0.4 145 6 143 305 1 0 1 0 4.4 0 4.9 4.2 10/17/2004 01:10:00 7.5 0.7 9.1 4.9 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 147 6 159 305 1 0 1 0 4.3 0 4.7 4.2 10/17/2004 01:20:00 7.1 0.7 9.1 4.9 6.9 0.6 8.8 5.3 0.4 0 0.4 0.4 148 6 148 305 1 0 1 0 4.4 0 4.9 4.4 10/17/2004 01:30:00 7.3 0.6 9.1 5.7 7.1 0.6 8.8 5.7 0.4 0 0.4 0.4 148 7 154 305 1 0 1 0 4.5 0.1 4.9 4.4 10/17/2004 01:40:00 7.6 0.5 8.8 6.1 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 144 5 138 305 1 0 1 0 4.5 0.1 4.9 4.4 10/17/2004 01:50:00 6.9 0.5 8.4 4.9 6.5 0.5 8 5.3 0.4 0 0.4 0.4 146 6 135 305 2 0 1 0 4.5 0 4.9 4.4 10/17/2004 02:00:00 6.7 0.6 8 4.9 6.4 0.6 8 4.9 0.4 0 0.4 0.4 145 6 152 305 2 0 1 0 4.5 0.1 4.9 4.4 10/17/2004 02:10:00 5.9 0.7 8 4.6 5.7 0.6 7.6 4.2 0.4 0 0.4 0.4 151 6 152 305 2 0 2 0 4.6 0.1 4.9 4.4 10/17/2004 02:20:00 6.3 0.6 7.6 4.6 6.1 0.5 7.2 4.6 0.4 0 0.4 0.4 151 5 156 305 2 0 2 0 4.7 0.1 5.2 4.4 10/17/2004 02:30:00 6 0.6 7.6 4.2 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 155 6 151 305 2 0 2 0 4.6 0 5.2 4.4 10/17/2004 02:40:00 6.5 0.6 8 4.9 6.3 0.5 7.6 5.3 0.4 0 0.4 0.4 152 6 151 305 2 0 2 0 4.6 0.1 5.2 4.4 10/17/2004 02:50:00 6.8 0.5 8 5.3 6.5 0.5 7.6 4.6 0.4 0 0.4 0.4 145 5 144 305 2 0 2 0 4.5 0.1 4.9 4.4 10/17/2004 03:00:00 6.4 0.6 8 4.6 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 150 5 152 305 2 0 1 0 4.5 0.1 4.9 4.4 10/17/2004 03:10:00 6.3 0.5 7.6 4.6 6.1 0.5 7.2 4.6 0.4 0 0.4 0.4 150 6 153 305 2 0 2 0 4.4 0.1 4.9 4.4 10/17/2004 03:20:00 5.8 0.7 7.6 3.4 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 156 7 145 305 2 0 2 0 4.5 0.1 4.9 4.4 10/17/2004 03:30:00 6.3 0.6 7.6 4.6 6.1 0.6 7.2 4.2 0.4 0 0.4 0.4 152 5 163 305 2 0 2 0 4.4 0 4.9 4.4 10/17/2004 03:40:00 6.6 0.6 8.4 4.6 6.5 0.5 8.4 4.9 0.4 0 0.4 0.4 146 5 147 305 2 0 2 0 4.4 0.1 4.9 4.4 10/17/2004 03:50:00 6.2 0.5 7.2 4.9 5.9 0.5 6.8 4.6 0.4 0 0.4 0.4 149 4 151 305 2 0 2 0 4.4 0 4.9 4.4 10/17/2004 04:00:00 6.6 0.7 8.4 4.6 6.3 0.7 8 4.6 0.4 0 0.4 0.4 146 5 142 305 2 0 2 0 4.5 0.1 4.9 4.4 10/17/2004 04:10:00 7.1 0.5 8 5.3 6.8 0.5 8.4 5.3 0.4 0 0.4 0.4 142 5 142 305 2 0 2 0 4.5 0.1 4.9 4.4 10/17/2004 04:20:00 7.3 0.6 8.8 5.7 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 146 5 138 305 2 0 2 0 4.5 0.1 4.9 4.4 10/17/2004 04:30:00 7.2 0.7 9.1 5.3 6.9 0.6 8.4 4.9 0.4 0 0.4 0.4 153 6 159 305 2 0 2 0 4.6 0 5.2 4.4 10/17/2004 04:40:00 6.5 0.6 7.6 4.2 6.2 0.6 7.6 4.9 0.4 0 0.4 0.4 153 6 162 305 2 0 2 0 4.6 0 4.9 4.4 10/17/2004 04:50:00 6.9 0.6 8.4 4.9 6.9 0.5 8 5.3 0.4 0 0.4 0.4 155 5 152 305 2 0 2 0 4.7 0 5.4 4.4 10/17/2004 05:00:00 6.9 0.8 8.4 4.2 7 0.6 8.4 4.6 0.4 0 0.4 0.4 157 5 154 305 2 0 2 0 4.9 0.1 5.4 4.7 10/17/2004 05:10:00 5.3 0.8 7.6 3 6.5 0.4 7.6 5.3 0.4 0 0.4 0.4 163 5 158 305 2 0 2 0 5.2 0 5.6 5.2 10/17/2004 05:20:00 4.9 1.1 6.8 2.6 5.8 0.5 6.8 3.8 0.4 0 0.4 0.4 175 11 186 305 2 0 2 0 5.3 0 5.6 5.2 10/17/2004 05:30:00 5.1 0.8 6.5 2.6 5.4 0.6 6.5 3.4 0.4 0 0.4 0.4 174 12 186 305 2 0 2 0 5.6 0.1 6.1 5.4 10/17/2004 05:40:00 5.8 0.8 7.6 3.4 6.1 0.4 7.2 4.9 0.4 0 0.4 0.4 155 8 144 305 2 0 2 0 5.4 0.1 5.9 4.9 10/17/2004 05:50:00 6.9 0.5 8 5.3 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 144 3 141 305 2 0 2 0 4.8 0 5.4 4.7 10/17/2004 06:00:00 6.2 0.6 7.6 4.6 6 0.5 7.2 4.6 0.4 0 0.4 0.4 150 5 155 305 2 0 2 0 4.8 0 5.4 4.7 10/17/2004 06:10:00 6.3 0.5 7.6 4.9 6.2 0.5 7.6 4.9 0.4 0 0.4 0.4 147 5 140 305 2 0 2 0 4.8 0 5.2 4.7 10/17/2004 06:20:00 6.8 0.4 7.6 5.7 6.5 0.4 7.6 5.7 0.4 0 0.4 0.4 142 5 139 305 2 0 2 0 4.8 0 5.2 4.7 10/17/2004 06:30:00 6.7 0.5 8 4.9 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 142 3 141 305 2 0 2 0 4.8 0 5.4 4.7 10/17/2004 06:40:00 6.1 0.6 7.2 4.2 5.9 0.5 7.2 4.2 0.4 0 0.4 0.4 145 5 147 305 2 0 2 0 4.8 0 5.4 4.7 10/17/2004 06:50:00 6.7 0.6 8.4 4.9 6.6 0.5 8 5.3 0.4 0 0.4 0.4 141 5 146 305 2 0 2 0 4.8 0 5.4 4.9 10/17/2004 07:00:00 6.1 0.9 8.4 4.2 5.9 0.8 8 4.6 0.4 0 0.4 0.4 145 7 144 305 2 0 2 0 4.9 0.1 5.4 4.9 10/17/2004 07:10:00 6.4 0.6 8 4.6 6.1 0.6 8 4.6 0.4 0.5 6.1 0.4 141 6 148 305 4 8 2 0 4.8 0 5.4 4.7 10/17/2004 07:20:00 6.8 0.6 8.4 5.3 6.6 0.6 8 4.9 0.4 0 0.7 0.4 139 4 141 305 56 29 68 0 4.8 0 5.4 4.7 10/17/2004 07:30:00 7.1 0.7 8.8 4.9 6.8 0.6 8.4 4.9 0.4 0 0.7 0.4 139 5 150 305 68 0 68 0 4.8 0 5.4 4.7 10/17/2004 07:40:00 7.1 0.6 8.8 5.3 6.9 0.6 8.8 5.3 0.4 0 0.4 0.4 140 5 143 305 68 0 68 0 4.8 0 5.4 4.7 10/17/2004 07:50:00 7.1 0.6 8.8 5.3 6.8 0.6 8.4 4.9 0.4 0 0.4 0.4 143 6 156 305 69 0 69 0 4.8 0 5.4 4.7 10/17/2004 08:00:00 7 0.7 8.8 4.9 6.8 0.7 8.8 5.3 0.4 0 0.4 0.4 142 6 143 305 71 0 72 0 4.9 0 5.4 4.7 10/17/2004 08:10:00 7.7 0.9 9.9 5.3 7.3 0.8 9.5 5.3 0.4 0 0.4 0.4 147 6 152 305 73 0 72 0 4.9 0.1 5.4 4.7 10/17/2004 08:20:00 7 1.1 9.1 4.2 6.7 1 8.8 4.6 0.4 0 0.4 0.4 147 7 150 305 73 0 73 0 4.9 0 5.4 4.7 10/17/2004 08:30:00 5.7 0.9 8 3.4 5.7 0.8 8 4.2 0.4 0 0.4 0.4 154 7 139 305 74 0 74 0 4.9 0 5.4 4.7 10/17/2004 08:40:00 5.4 1 8 2.6 5.3 0.7 7.2 3.8 0.4 0 0.4 0.4 149 10 155 305 75 0 75 0 4.9 0.1 5.4 4.7 10/17/2004 08:50:00 5.5 0.9 8 2.6 5.7 0.8 8.4 3 0.4 0 0.4 0.4 154 9 155 305 75 0 76 0 4.8 0 5.4 4.7 10/17/2004 09:00:00 6.2 0.9 8 3.8 6.3 0.8 8.4 4.2 0.4 0 0.4 0.4 156 7 154 305 76 0 76 0 4.7 0 5.4 4.7 10/17/2004 09:10:00 7.1 0.9 9.1 4.2 7 0.8 8.8 4.9 0.4 0 0.4 0.4 151 8 145 305 76 0 77 0 4.7 0 5.2 4.7 10/17/2004 09:20:00 7.2 0.7 8.8 5.3 6.9 0.7 8.8 5.3 0.4 0 0.4 0.4 147 6 145 305 76 0 77 0 4.5 0 4.9 4.4 10/17/2004 09:30:00 7.1 0.8 9.1 5.3 6.7 0.7 8.8 4.9 0.4 0 0.4 0.4 145 7 152 305 76 0 77 0 4.5 0 4.9 4.4 10/17/2004 09:40:00 7.1 0.8 9.1 5.3 6.8 0.7 9.1 4.6 0.4 0 0.4 0.4 146 8 150 305 77 0 77 0 4.5 0 5.2 4.4 10/17/2004 09:50:00 6.3 0.9 8.4 4.6 6.2 0.8 8.4 4.2 0.4 0 0.4 0.4 143 8 147 305 76 0 77 0 4.5 0 4.9 4.4 10/17/2004 10:00:00 6.2 0.6 8.4 4.9 6 0.7 8 4.6 0.4 0 0.4 0.4 140 8 134 305 77 0 77 0 4.5 0 4.9 4.4 10/17/2004 10:10:00 6 0.7 7.6 3.8 5.9 0.6 7.6 4.2 0.4 0 0.4 0.4 140 8 140 305 77 0 77 0 4.5 0 4.7 4.4 10/17/2004 10:20:00 6 0.5 7.2 4.6 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 136 6 147 305 77 0 77 0 4.5 0 4.9 4.4 10/17/2004 10:30:00 6.1 0.7 8 4.6 5.8 0.6 8 4.6 0.4 0 0.4 0.4 135 7 138 305 77 0 77 0 4.4 0.1 4.9 4.4 10/17/2004 10:40:00 6.5 0.8 9.1 3.8 6.2 0.8 8 4.6 0.4 0 0.4 0.4 134 9 134 305 77 0 77 0 4.6 0 4.9 4.4 10/17/2004 10:50:00 6.4 0.8 8.4 4.2 6.2 0.8 8.8 4.2 0.4 0 0.4 0.4 133 10 120 305 77 0 77 0 4.8 0 5.2 4.7 10/17/2004 11:00:00 8.9 1.1 12.6 5.7 8.7 1 12.2 5.3 0.4 0 0.4 0.4 132 9 143 305 76 0 76 0 4.8 0 5.4 4.9 10/17/2004 11:10:00 7.2 1.3 10.7 3.8 7 1.3 10.3 4.6 0.4 0 0.4 0.4 131 10 141 305 76 0 77 0 4.8 0 5.4 4.7 10/17/2004 11:20:00 7.9 1 9.9 5.3 7.7 0.9 9.9 5.3 0.4 0 0.4 0.4 136 10 123 305 75 0 76 0 4.7 0 5.2 4.7 10/17/2004 11:30:00 6.8 1 9.9 4.6 6.6 1 9.5 3.8 0.4 0 0.4 0.4 142 10 141 305 75 0 75 0 4.7 0 4.9 4.7 10/17/2004 11:40:00 7.5 1.2 10.7 4.2 7.4 1.1 10.3 4.9 0.4 0 0.4 0.4 137 9 131 305 75 0 75 0 4.7 0 5.2 4.7 10/17/2004 11:50:00 6.2 0.8 8.8 3.8 6.1 0.8 8.8 3.8 0.4 0 0.4 0.4 136 10 136 305 74 0 74 0 4.7 0 5.2 4.7 10/17/2004 12:00:00 6.3 0.8 8 3.8 6.1 0.9 8 3.8 0.4 0 0.4 0.4 135 6 134 305 74 0 74 0 4.7 0 5.2 4.7 10/17/2004 12:10:00 5 0.7 7.2 3.4 4.9 0.7 6.5 3 0.4 0 0.4 0.4 135 8 139 305 74 0 74 0 4.7 0 5.2 4.7 10/17/2004 12:20:00 4.6 0.6 6.1 2.6 4.5 0.5 5.7 2.6 0.4 0 0.4 0.4 134 7 130 305 74 0 74 0 4.7 0 5.2 4.7 10/17/2004 12:30:00 4.3 0.9 6.8 1.5 4.2 0.8 5.7 2.3 0.4 0 0.4 0.4 140 12 130 305 74 0 74 0 4.7 0 5.2 4.7 10/17/2004 12:40:00 5.1 1 8 3 5.1 1.1 7.6 2.6 0.4 0 0.4 0.4 144 13 136 305 74 0 74 0 4.8 0 5.2 4.7 10/17/2004 12:50:00 6 1.2 8.4 2.6 5.9 1.2 8.4 3.4 0.4 0 0.4 0.4 140 12 135 305 74 0 74 0 4.8 0 5.4 4.7 10/17/2004 13:00:00 7.2 1.2 9.5 4.2 7.1 1.2 9.9 3.4 0.4 0 0.4 0.4 135 10 133 305 74 0 74 0 4.9 0.1 5.4 4.9 10/17/2004 13:10:00 7.7 1 10.3 4.9 7.6 1 9.5 4.9 0.4 0 0.4 0.4 133 8 105 305 75 0 74 0 4.8 0 5.4 4.9 10/17/2004 13:20:00 8.5 1 11.1 6.1 8.4 1 11.1 5.3 0.4 0 0.4 0.4 133 7 137 305 75 0 75 0 4.8 0 5.4 4.9 10/17/2004 13:30:00 8.3 1.1 10.7 4.9 8.1 1.1 10.7 5.3 0.4 0 0.4 0.4 136 8 137 305 75 0 75 0 4.9 0.1 5.4 4.9 10/17/2004 13:40:00 7.5 1.4 11.5 4.2 7.4 1.4 11.5 4.9 0.4 0 0.4 0.4 133 13 150 305 75 0 75 0 4.9 0.1 5.4 4.9 10/17/2004 13:50:00 7.5 1.2 10.7 4.6 7.3 1.2 10.3 4.6 0.4 0 0.4 0.4 123 13 127 305 75 0 74 0 4.9 0.1 5.4 4.9 10/17/2004 14:00:00 7.1 1.3 10.3 4.2 6.9 1.3 9.9 3.4 0.4 0 0.4 0.4 119 15 143 305 74 0 74 0 4.9 0.1 5.6 4.9 10/17/2004 14:10:00 6.2 1.5 11.1 3.4 6.1 1.5 11.8 2.6 0.4 0 0.4 0.4 116 16 138 305 74 0 74 0 5 0.1 5.6 4.9 10/17/2004 14:20:00 6 1.3 11.5 2.6 5.8 1.3 11.1 2.6 0.4 0 0.4 0.4 121 17 111 305 74 0 74 0 5.1 0.1 5.6 4.9 10/17/2004 14:30:00 7.2 1.5 10.7 3 6.9 1.4 10.3 2.6 0.4 0 0.4 0.4 118 15 141 305 74 0 74 0 5.2 0.1 5.6 4.9 10/17/2004 14:40:00 8 1.7 12.6 3.8 7.8 1.8 12.6 3.4 0.4 0 0.4 0.4 122 15 111 305 74 0 74 0 5.2 0 5.9 5.2 10/17/2004 14:50:00 8.6 1.4 12.2 3.8 8.3 1.5 12.2 3 0.4 0 0.4 0.4 122 13 130 305 76 1 77 0 5.3 0 5.9 5.4 10/17/2004 15:00:00 7.3 1.6 10.3 3.8 7.1 1.5 9.9 3.4 0.4 0 0.4 0.4 120 12 137 305 76 0 76 0 5.5 0.1 6.1 5.4 10/17/2004 15:10:00 6.8 1.3 10.3 4.2 6.6 1.3 10.7 3 0.4 0 0.4 0.4 115 17 125 305 76 0 77 0 5.8 0 6.1 5.6 10/17/2004 15:20:00 6.3 1.5 10.3 3 6 1.5 9.5 2.6 0.4 0 0.4 0.4 112 17 123 305 76 0 76 0 6 0.1 6.7 5.9 10/17/2004 15:30:00 6.4 1.1 9.9 3.4 6.3 1.2 9.9 3.4 0.4 0 0.4 0.4 111 17 94 305 76 0 76 0 5.6 0.1 6.1 5.4 10/17/2004 15:40:00 5.1 1.3 8.8 2.6 5 1.3 8.8 2.3 0.4 0 0.4 0.4 124 18 146 305 75 0 76 0 5.3 0.1 5.9 5.2 10/17/2004 15:50:00 3.9 1.4 9.1 0.4 4 1.2 8.8 1.1 0.4 0 0.4 0.4 118 22 128 305 75 0 75 0 5.2 0 5.6 4.9 10/17/2004 16:00:00 4.3 1.3 8 1.1 4.2 1.2 7.6 1.5 0.4 0 0.4 0.4 122 27 143 305 75 0 76 0 5.1 0 5.6 4.9 10/17/2004 16:10:00 4.2 1.7 8.4 0.4 4.3 1.7 8 1.1 0.4 0 0.4 0.4 134 19 149 305 75 0 76 0 5.2 0 5.6 5.2 10/17/2004 16:20:00 3.4 1.4 8.4 0.4 3.6 1.2 8 0.7 0.4 0 0.4 0.4 118 28 116 305 75 0 76 0 5.2 0 5.9 5.2 10/17/2004 16:30:00 4.6 1.5 9.5 1.5 4.6 1.5 8.8 1.9 0.4 0 0.4 0.4 131 28 152 305 76 0 76 0 5.5 0.1 5.9 5.4 10/17/2004 16:40:00 7.1 1.5 10.3 3.4 7 1.3 9.9 3.8 0.4 0 0.4 0.4 139 11 134 305 76 0 76 0 5.6 0.1 6.1 5.4 10/17/2004 16:50:00 6.9 1 9.1 3.8 6.8 1 9.9 4.2 0.4 0 0.4 0.4 135 9 131 305 76 0 76 0 5.5 0 5.9 5.4 10/17/2004 17:00:00 5.8 0.9 8.4 3.4 5.8 0.9 8 3.4 0.4 0 0.4 0.4 139 10 152 305 76 0 76 0 5.3 0 5.9 5.2 10/17/2004 17:10:00 4.6 1.1 7.2 2.3 4.6 1 7.2 2.6 0.4 0 0.4 0.4 144 15 144 305 76 0 76 0 5.2 0.1 5.6 4.9 10/17/2004 17:20:00 5.2 1.1 8 1.9 5.3 1 7.2 3 0.4 0 0.7 0.4 150 10 152 305 76 0 76 0 5.1 0.1 5.6 4.9 10/17/2004 17:30:00 7.1 0.9 9.5 4.6 7 0.9 9.5 3.8 0.4 0 0.4 0.4 137 10 131 305 76 0 76 0 4.9 0.1 5.4 4.7 10/17/2004 17:40:00 6.2 0.8 8.4 3.8 6 0.8 8 3.4 0.4 0 0.4 0.4 138 12 96 305 76 0 76 0 4.8 0 5.4 4.7 10/17/2004 17:50:00 6.6 1 9.1 3.8 6.5 1 8.8 3.8 0.4 0 0.4 0.4 137 10 135 305 76 0 76 0 4.8 0 5.2 4.7 10/17/2004 18:00:00 6.4 1 8.4 3.4 6.2 0.9 8.4 3.8 0.4 0 0.4 0.4 135 9 129 305 76 0 76 0 4.8 0 5.2 4.7 10/17/2004 18:10:00 7.5 1.1 9.5 4.9 7.2 1.1 9.9 4.6 0.4 0 0.4 0.4 134 8 141 305 76 0 76 0 4.8 0 5.4 4.7 10/17/2004 18:20:00 8.1 1 10.7 4.6 7.9 1 10.7 4.9 0.4 0 0.4 0.4 136 8 128 305 76 0 76 0 4.8 0 5.4 4.7 10/17/2004 18:30:00 8.7 1 11.8 6.1 8.6 0.9 12.2 6.1 0.4 0 0.4 0.4 134 8 127 305 76 0 76 0 4.7 0 5.2 4.7 10/17/2004 18:40:00 9.1 1.2 11.8 5.7 9 1.1 11.8 5.7 0.4 0 0.4 0.4 134 8 145 305 76 0 76 0 4.5 0.1 4.9 4.4 10/17/2004 18:50:00 9.4 1.2 12.2 5.7 9.2 1.1 12.6 6.1 0.4 0 0.4 0.4 130 9 137 305 76 0 76 0 4.5 0.1 4.9 4.4 10/17/2004 19:00:00 7.2 1.8 12.2 1.9 7.1 1.7 11.5 4.2 0.4 0 0.4 0.4 123 16 108 305 76 0 76 0 4.5 0.1 4.9 4.4 10/17/2004 19:10:00 6.8 1.7 12.6 3.4 6.7 1.6 12.2 3 0.4 0 0.4 0.4 122 17 119 305 76 0 76 0 4.5 0.1 4.9 4.4 10/17/2004 19:20:00 8.2 1.7 12.6 3.8 7.8 1.8 12.6 3.8 0.4 0 0.4 0.4 120 18 93 305 76 0 77 0 4.5 0 4.9 4.4 10/17/2004 19:30:00 8.4 1.8 13.7 3.4 8.3 1.9 13.3 3.8 0.4 0 0.4 0.4 127 17 105 305 75 2 77 0 4.5 0.1 4.9 4.4 10/17/2004 19:40:00 9.7 1.9 15.3 4.9 9.6 1.7 14.5 4.2 0.4 0 0.4 0.4 132 17 134 305 69 1 68 0 4.4 0 4.9 4.4 10/17/2004 19:50:00 10.7 1.4 14.1 8 10.6 1.3 14.5 8 0.4 0 0.4 0.4 131 12 139 305 68 0 68 0 4.3 0 4.7 4.2 10/17/2004 20:00:00 10.7 1.8 16.4 5.7 10.5 1.9 16.4 5.7 0.4 0 0.4 0.4 129 14 134 305 68 0 68 0 4.2 0 4.7 4.2 10/17/2004 20:10:00 10.7 1.8 16.1 5.3 10.5 2 16.8 4.9 0.4 0 0.7 0.4 130 15 129 305 69 0 68 0 4 0 4.7 3.9 10/17/2004 20:20:00 11.2 2.2 17.6 6.8 11.1 2.3 18.7 6.5 0.4 0 0.4 0.4 122 14 127 305 68 0 68 0 3.9 0.1 4.4 3.7 10/17/2004 20:30:00 12.8 2.3 18.7 6.5 12.4 2.3 18.7 6.1 0.4 0 0.4 0.4 133 12 128 305 68 0 68 0 3.8 0.1 4.4 3.7 10/17/2004 20:40:00 13.8 1.8 18.7 6.8 13.6 1.8 18.7 6.5 0.4 0 0.4 0.4 134 9 130 305 68 0 68 0 3.9 0.1 4.4 3.7 10/17/2004 20:50:00 13.2 2 17.9 6.8 13 2 18.7 7.2 0.4 0 0.4 0.4 130 12 120 305 69 0 69 0 3.8 0.1 4.4 3.7 10/17/2004 21:00:00 12 2 17.6 6.8 11.7 2 17.2 6.8 0.4 0 0.4 0.4 122 12 118 305 69 0 69 0 3.8 0.1 4.4 3.7 10/17/2004 21:10:00 12.2 2.4 16.8 3.4 11.9 2.3 16.8 3.8 0.4 0 0.4 0.4 121 15 129 305 69 0 69 0 3.7 0 4.2 3.7 10/17/2004 21:20:00 10.3 1.8 15.3 5.3 10.2 1.9 15.6 5.7 0.4 0 0.4 0.4 123 16 128 305 69 0 69 0 3.6 0 4.2 3.4 10/17/2004 21:30:00 11.4 1.8 18.3 6.5 11.5 1.8 16.4 7.2 0.4 0 0.4 0.4 130 12 133 305 69 0 69 0 3.6 0 4.2 3.4 10/17/2004 21:40:00 11.6 2.2 19.1 6.8 11.4 2.2 17.2 6.5 0.4 0 0.4 0.4 129 15 133 305 69 0 69 0 3.6 0 4.2 3.4 10/17/2004 21:50:00 13.1 2.4 20.2 6.1 12.8 2.4 19.1 6.5 0.4 0 0.7 0.4 133 12 127 305 68 0 67 0 3.5 0 3.9 3.4 10/17/2004 22:00:00 14.5 2 18.3 9.1 14.4 2 19.1 8.8 0.4 0 0.4 0.4 130 11 134 305 67 0 67 0 3.4 0.1 3.9 3.4 10/17/2004 22:10:00 12.8 1.7 17.9 8.8 12.7 1.8 18.3 8 0.4 0 0.4 0.4 125 13 124 305 66 0 66 0 3.4 0 3.9 3.4 10/17/2004 22:20:00 13.3 1.9 19.1 8.8 13.1 2 18.7 8.4 0.4 0 0.4 0.4 129 12 129 305 66 0 66 0 3.4 0.1 3.9 3.2 10/17/2004 22:30:00 13.3 2.1 17.9 6.8 13.1 2.1 18.3 6.8 0.4 0 0.4 0.4 133 10 123 305 66 0 65 0 3.4 0.1 3.9 3.2 10/17/2004 22:40:00 11.7 2 16.4 6.5 11.5 1.8 16.1 6.5 0.4 0 0.4 0.4 120 13 119 305 66 0 66 0 3.3 0 3.7 3.2 10/17/2004 22:50:00 11.9 2.1 19.5 6.5 11.9 2 17.9 6.5 0.4 0 0.4 0.4 123 12 115 305 67 0 67 0 3.3 0 3.7 3.2 10/17/2004 23:00:00 10.5 1.7 15.3 6.1 10.6 1.8 15.6 5.7 0.4 0 0.4 0.4 122 14 105 305 67 0 67 0 3.3 0 3.7 3.2 10/17/2004 23:10:00 11.3 1.9 15.6 6.5 11.2 2 16.1 6.1 0.4 0 0.4 0.4 121 13 121 305 68 0 68 0 3.2 0 3.7 3.2 10/17/2004 23:20:00 12.1 1.7 16.8 7.6 11.9 1.5 16.1 7.6 0.4 0 0.4 0.4 122 12 126 305 68 0 68 0 3.3 0 3.7 3.2 10/17/2004 23:30:00 9.7 1.6 14.1 5.7 9.6 1.6 14.9 5.3 0.4 0 0.4 0.4 121 15 110 305 67 0 67 0 3.3 0.1 3.7 3.2 10/17/2004 23:40:00 9 1.5 12.6 5.3 8.9 1.5 13.3 5.3 0.4 0 0.4 0.4 114 15 116 305 68 0 67 0 3.4 0.1 3.9 3.2 10/17/2004 23:50:00 8.2 1.8 12.6 3.8 8 1.7 13 4.2 0.4 0 0.4 0.4 112 17 119 305 67 0 67 0 3.4 0 3.9 3.4 10/18/2004 00:00:00 8.2 1.8 12.6 4.2 7.9 1.9 13 4.2 0.4 0 0.4 0.4 108 17 112 305 67 0 67 0 3.6 0.1 4.2 3.4 10/18/2004 00:10:00 8.8 1.7 13.7 5.3 8.5 1.9 14.5 4.9 0.4 0 0.4 0.4 110 15 99 305 67 0 67 0 3.5 0 4.2 3.4 10/18/2004 00:20:00 8.6 1.7 14.9 4.6 8.4 1.6 14.1 5.3 0.4 0 0.4 0.4 114 19 128 305 66 0 66 0 3.5 0.1 3.9 3.4 10/18/2004 00:30:00 9.6 1.7 14.5 5.3 9.3 1.7 14.1 4.9 0.4 0 0.4 0.4 118 16 143 305 66 0 66 0 3.6 0.1 4.2 3.4 10/18/2004 00:40:00 9.9 1.9 14.1 4.9 9.5 1.8 13.7 5.3 0.4 0 0.4 0.4 109 13 111 305 65 0 65 0 3.6 0 4.2 3.4 10/18/2004 00:50:00 7.8 2.3 14.5 1.9 7.5 2.3 13.3 2.6 0.4 0 0.4 0.4 102 24 103 305 65 0 65 0 3.6 0 4.2 3.4 10/18/2004 01:00:00 8.4 2.3 16.1 3 8 2.4 15.6 3.4 0.4 0 0.4 0.4 82 21 80 305 65 0 65 0 3.7 0 4.2 3.4 10/18/2004 01:10:00 8.7 2 13.7 4.2 8.4 2 14.1 3.8 0.4 0 0.4 0.4 78 21 65 305 65 0 66 0 3.8 0 4.4 3.7 10/18/2004 01:20:00 7.8 1.8 12.6 3.4 7.7 1.9 13 3 0.4 0 0.4 0.4 77 23 77 305 66 0 66 0 3.9 0.1 4.4 3.7 10/18/2004 01:30:00 8.1 2.1 13.7 3.4 7.7 2.1 13 3.4 0.4 0 0.4 0.4 73 17 66 305 66 0 66 0 3.9 0.1 4.4 3.7 10/18/2004 01:40:00 7.9 1.6 13.3 4.2 7.6 1.7 13.7 3.4 0.4 0 0.4 0.4 65 16 58 305 67 0 67 0 4 0.1 4.4 3.9 10/18/2004 01:50:00 8.5 1.9 13.7 4.2 8.2 2 13.7 2.6 0.4 0 0.4 0.4 63 16 78 305 66 0 67 0 4 0 4.7 3.9 10/18/2004 02:00:00 6.9 1.9 11.5 1.9 6.8 2.1 11.8 2.3 0.4 0 0.4 0.4 65 26 70 305 66 0 66 0 4.1 0 4.7 4.2 10/18/2004 02:10:00 6 1.8 11.8 0.4 5.5 1.7 9.9 0.7 0.4 0 0.4 0.4 72 26 103 305 66 0 66 0 4.1 0 4.7 4.2 10/18/2004 02:20:00 6.8 2.2 13.3 1.9 6.5 2 12.6 2.6 0.4 0 0.4 0.4 76 24 85 305 66 0 65 0 4.3 0 4.7 4.2 10/18/2004 02:30:00 6 2.1 12.2 1.9 5.8 1.9 11.5 2.3 0.4 0 0.4 0.4 68 23 86 305 66 0 67 0 4.4 0 4.9 4.2 10/18/2004 02:40:00 4.6 1.9 8.8 0.4 4.3 1.7 8 0.7 0.4 0 0.4 0.4 98 49 71 305 67 0 67 0 4.4 0 4.9 4.4 10/18/2004 02:50:00 3.9 1.7 9.5 0.4 3.9 1.6 9.1 0.4 0.4 0 0.4 0.4 87 38 30 305 66 0 66 0 4.4 0 4.9 4.2 10/18/2004 03:00:00 4.2 2.4 11.8 0.4 4.1 1.9 11.1 0.4 0.4 0 0.4 0.4 91 47 83 305 66 0 66 0 4.4 0 4.9 4.2 10/18/2004 03:10:00 7 2.1 14.5 2.6 6.7 1.7 12.2 2.3 0.4 0 0.4 0.4 104 26 121 305 65 1 64 0 4.4 0.2 4.9 4.2 10/18/2004 03:20:00 8.8 2.1 14.9 4.6 8.6 2 14.5 4.6 0.4 0 0.4 0.4 108 20 124 305 63 0 64 0 4.4 0.1 4.9 4.2 10/18/2004 03:30:00 8.7 2.3 16.4 3.4 8.4 2.1 14.9 4.6 0.4 0 0.4 0.4 103 24 99 305 63 0 63 0 4.3 0.1 4.7 4.2 10/18/2004 03:40:00 7.1 2.2 13.7 1.9 6.8 1.9 12.6 1.5 0.4 0 0.4 0.4 97 30 64 305 63 0 63 0 4.4 0.2 4.9 4.2 10/18/2004 03:50:00 4.8 2.5 12.2 0.4 4.8 2.3 10.3 0.4 0.4 0 0.4 0.4 91 49 56 305 63 0 63 0 4.4 0.2 4.9 4.4 10/18/2004 04:00:00 6.8 2.4 13.3 0.4 6.7 2.4 14.1 1.1 0.4 0 0.4 0.4 104 32 95 305 63 0 64 0 4.4 0.1 4.9 4.2 10/18/2004 04:10:00 8.8 2.4 14.9 3.4 8.5 2.3 15.3 3.4 0.4 0 0.4 0.4 111 22 114 305 63 1 63 0 4.4 0.1 4.9 4.2 10/18/2004 04:20:00 8 2.6 16.8 3 7.7 2.6 15.3 2.6 0.4 0 0.4 0.4 110 26 124 305 61 0 62 0 4.4 0.1 4.9 4.4 10/18/2004 04:30:00 7.6 2.3 14.5 1.5 7.2 2.2 13.7 1.9 0.4 0 0.4 0.4 98 24 123 305 60 0 59 0 4.4 0.2 4.9 4.4 10/18/2004 04:40:00 8.2 2.2 13.3 2.6 7.8 2.1 14.1 2.6 0.4 0 0.4 0.4 78 26 71 305 59 0 59 0 4.5 0.1 4.9 4.4 10/18/2004 04:50:00 6.5 1.8 12.6 1.9 6.2 1.7 13 1.5 0.4 0 0.4 0.4 83 29 75 305 58 0 59 0 4.5 0.1 4.9 4.4 10/18/2004 05:00:00 7.8 2.5 14.5 1.9 7.6 2.5 15.3 2.3 0.4 0 0.4 0.4 80 24 65 305 57 0 57 0 4.4 0.1 4.9 4.2 10/18/2004 05:10:00 8.8 2.7 16.1 2.3 8.6 2.8 17.2 2.3 0.4 0 0.4 0.4 74 29 46 305 56 0 56 0 4.4 0.1 4.9 4.2 10/18/2004 05:20:00 9.8 2.7 16.8 2.3 9.1 2.7 16.4 1.9 0.4 0 0.4 0.4 72 30 58 305 55 0 55 0 4.5 0.1 5.2 4.4 10/18/2004 05:30:00 11.4 3.2 19.1 3 11.3 3.5 19.9 3 0.4 0 0.4 0.4 67 18 75 305 53 1 52 0 4.7 0 5.2 4.4 10/18/2004 05:40:00 12.6 2.6 19.5 6.8 12.2 2.9 20.2 6.8 0.4 0 0.4 0.4 71 15 60 305 51 0 51 0 4.7 0 5.4 4.4 10/18/2004 05:50:00 14.1 2.6 20.2 8 14.2 2.7 21 7.2 0.4 0 0.4 0.4 64 13 64 305 52 0 52 0 4.6 0 5.2 4.4 10/18/2004 06:00:00 13.9 2.8 20.6 6.8 13.7 2.9 21.4 5.7 0.4 0 0.4 0.4 67 13 72 305 53 0 54 0 4.6 0 5.2 4.4 10/18/2004 06:10:00 13.8 2.8 22.1 4.6 14 2.8 22.9 5.7 0.4 0 0.4 0.4 68 15 77 305 65 10 73 0 4.7 0 5.2 4.7 10/18/2004 06:20:00 13.1 3.2 20.6 3.4 12.9 3.3 22.6 4.6 0.4 0 0.4 0.4 63 20 73 305 78 2 74 0 4.7 0 5.4 4.7 10/18/2004 06:30:00 13.3 3.1 22.1 3.8 13.6 3.1 21 4.2 0.4 0 0.4 0.4 61 18 67 305 78 0 78 0 4.7 0 5.4 4.7 10/18/2004 06:40:00 13 4 23.7 1.5 13 4.1 25.2 4.9 0.4 0 0.4 0.4 68 27 55 305 76 1 76 0 4.8 0 5.4 4.7 10/18/2004 06:50:00 14.1 3.5 26.3 5.7 14.1 3.5 26 4.9 0.4 0 0.4 0.4 63 16 59 305 73 2 74 0 4.8 0 5.4 4.7 10/18/2004 07:00:00 14.7 3.6 24.4 7.2 14.8 3.6 24 6.1 0.4 0 0.4 0.4 67 19 72 305 76 1 75 0 4.8 0 5.4 4.7 10/18/2004 07:10:00 16.9 3.2 24.4 7.2 17 3.3 25.6 6.1 0.4 0 0.4 0.4 64 13 62 305 77 0 77 0 4.9 0.1 5.4 4.9 10/18/2004 07:20:00 16.8 3.5 27.1 8 16.8 4 27.1 6.8 0.4 0 0.4 0.4 68 17 75 305 75 0 75 0 4.8 0 5.4 4.9 10/18/2004 07:30:00 15 3.5 25.6 4.9 15.4 3.8 27.5 6.5 0.4 0 0.4 0.4 64 17 54 305 74 0 74 0 4.9 0 5.4 4.9 10/18/2004 07:40:00 14 3.6 23.3 5.7 14.2 3.6 24.4 5.7 0.4 0 0.4 0.4 62 15 55 305 72 1 72 0 5 0.2 5.4 4.9 10/18/2004 07:50:00 13.6 3.6 21.8 3.4 13.4 3.6 22.9 3 0.4 0 0.4 0.4 66 18 67 305 70 1 70 0 5 0.2 5.4 4.9 10/18/2004 08:00:00 13.3 3.6 24.4 4.2 13 4 24 4.2 0.4 0 0.4 0.4 65 18 60 305 68 0 68 0 4.9 0.1 5.4 4.9 10/18/2004 08:10:00 12.8 3.3 21.8 4.2 12.8 3.5 21.4 4.2 0.4 0 0.4 0.4 62 17 54 305 67 0 67 0 4.9 0.1 5.4 4.9 10/18/2004 08:20:00 12.6 3.2 21.8 4.2 12.9 3.1 21 5.3 0.4 0 0.4 0.4 60 18 75 305 67 0 67 0 4.9 0.1 5.4 4.9 10/18/2004 08:30:00 11.8 3.3 23.7 3.8 11.8 3.5 24.4 4.2 0.4 0 0.4 0.4 66 20 62 305 67 0 67 0 4.9 0.1 5.4 4.9 10/18/2004 08:40:00 13 3.8 23.3 3.8 13.1 4 22.9 4.6 0.4 0 0.4 0.4 62 18 64 305 68 0 68 0 4.9 0.1 5.4 4.9 10/18/2004 08:50:00 14.3 3.3 22.1 5.7 14.3 3.6 22.9 4.6 0.4 0 0.4 0.4 61 20 56 305 68 0 68 0 4.9 0.1 5.4 4.9 10/18/2004 09:00:00 14.6 3.8 25.6 5.7 14.5 4.1 27.1 4.6 0.4 0 0.4 0.4 63 19 60 305 68 0 68 0 5 0.1 5.6 4.9 10/18/2004 09:10:00 16.1 4 24.8 5.7 15.9 4 24 5.7 0.4 0 0.4 0.4 65 17 53 305 69 0 69 0 5 0.2 5.6 4.9 10/18/2004 09:20:00 18.3 2.6 25.2 11.1 18.6 2.6 28.7 11.5 0.4 0 0.4 0.4 64 10 39 305 70 0 69 0 5 0.2 5.6 4.9 10/18/2004 09:30:00 18.5 2.7 26.8 11.8 18.4 2.7 27.1 10.7 0.4 0 0.4 0.4 68 9 69 305 70 0 70 0 4.9 0.1 5.4 4.7 10/18/2004 09:40:00 17.2 4 29.4 7.2 17.3 4 27.9 6.1 0.4 0 0.4 0.4 62 19 82 305 71 0 71 0 5 0.2 5.4 4.9 10/18/2004 09:50:00 18.6 4 27.5 7.6 18.7 4.3 30.9 7.6 0.4 0 0.4 0.4 65 14 82 305 72 1 72 0 4.9 0.1 5.4 4.7 10/18/2004 10:00:00 17.4 4.5 28.3 3.4 17.6 4.7 28.7 6.5 0.4 0 0.4 0.4 64 17 63 305 72 0 72 0 4.9 0.1 5.4 4.9 10/18/2004 10:10:00 16.4 3.8 25.6 4.2 16.3 4.1 27.5 5.7 0.4 0 0.4 0.4 63 19 52 305 72 0 72 0 5 0.1 5.6 4.9 10/18/2004 10:20:00 14.6 4.3 26 4.6 14.2 4.5 26.8 4.6 0.4 0 0.4 0.4 70 28 68 305 72 0 72 0 5 0.1 5.6 4.9 10/18/2004 10:30:00 16.8 3.5 27.5 8 16.5 3.8 26.8 6.8 0.4 0 0.4 0.4 61 22 76 305 72 0 72 0 5.1 0 5.6 4.9 10/18/2004 10:40:00 15.3 3.8 26.3 6.8 15.2 4.3 27.1 6.1 0.4 0 0.4 0.4 61 22 73 305 71 0 71 0 5.2 0 5.6 5.2 10/18/2004 10:50:00 13 3.8 22.9 2.6 12.7 3.8 24 2.6 0.4 0 0.4 0.4 66 21 69 305 72 0 72 0 5.4 0 5.9 5.2 10/18/2004 11:00:00 11.3 3.6 21 2.3 10.9 3.6 22.1 3 0.4 0 0.4 0.4 73 33 45 305 72 0 72 0 5.5 0.1 5.9 5.4 10/18/2004 11:10:00 10.5 3.3 19.5 3.8 9.7 3.3 18.3 3.4 0.4 0 0.4 0.4 86 41 72 305 73 1 72 0 5.5 0.1 5.9 5.4 10/18/2004 11:20:00 11.4 4 24 3 10.6 4 24.8 1.9 0.4 0 0.4 0.4 95 33 109 305 75 0 75 0 5.5 0.2 5.9 5.4 10/18/2004 11:30:00 9.1 3.6 21 1.5 8.7 3.5 20.6 1.5 0.4 0 0.4 0.4 103 36 140 305 76 1 76 0 5.6 0.1 6.1 5.4 10/18/2004 11:40:00 10.3 3.8 21.4 3.4 9.8 3.5 20.6 3 0.4 0 0.4 0.4 103 30 114 305 77 0 77 0 5.6 0.2 6.1 5.4 10/18/2004 11:50:00 9.7 3.8 21.4 2.6 9.1 3.6 19.1 3 0.4 0 0.4 0.4 100 35 116 305 77 0 78 0 5.5 0.1 5.9 5.4 10/18/2004 12:00:00 10.6 4.3 22.1 1.1 10.3 4.1 22.6 1.1 0.4 0 0.4 0.4 114 30 133 305 78 0 78 0 5.6 0.1 5.9 5.4 10/18/2004 12:10:00 10.6 3.6 21.8 1.1 10.3 3.6 22.6 3 0.4 0 0.4 0.4 116 24 102 305 78 0 78 0 5.6 0.2 6.1 5.4 10/18/2004 12:20:00 12.4 3.2 26 5.7 11.8 3.2 21 4.9 0.4 0 0.4 0.4 113 26 117 305 79 0 79 0 5.8 0 6.4 5.6 10/18/2004 12:30:00 13.1 3.2 22.6 3.8 12.7 3.2 20.6 3.8 0.4 0 0.4 0.4 125 22 147 305 79 0 79 0 6 0.2 6.4 5.9 10/18/2004 12:40:00 13.7 3.5 23.7 6.1 13.1 3.6 22.6 3.4 0.4 0 0.4 0.4 132 19 132 305 80 0 80 0 6.2 0.1 6.7 5.9 10/18/2004 12:50:00 12.6 3.2 22.9 4.9 12.2 3.1 22.6 4.9 0.4 0 0.4 0.4 133 17 132 305 81 0 81 0 6.3 0 6.9 6.1 10/18/2004 13:00:00 16 2.8 24 9.5 15.7 2.9 24.4 8.8 0.4 0 0.4 0.4 138 13 136 305 81 0 81 0 6.6 0.1 7.2 6.4 10/18/2004 13:10:00 16.4 2.8 23.7 8.8 16 2.6 22.9 9.1 0.4 0 0.4 0.4 139 11 131 305 82 1 84 0 6.9 0 7.4 6.7 10/18/2004 13:20:00 17.2 3.5 27.1 8.8 16.7 3.3 26.3 8.8 0.4 0 0.4 0.4 137 12 137 305 84 0 84 0 7.2 0.1 7.7 7.2 10/18/2004 13:30:00 16 2.9 24 9.5 15.6 2.7 24.4 9.9 0.4 0 0.4 0.4 138 12 145 305 82 1 82 0 7.4 0 7.9 7.4 10/18/2004 13:40:00 16.3 2.9 24 7.6 15.9 2.9 23.7 9.9 0.4 0 0.4 0.4 137 13 136 305 81 0 81 0 7.5 0 7.9 7.4 10/18/2004 13:50:00 16.8 2.8 24.8 9.9 16.5 2.7 24.4 10.7 0.4 0 0.4 0.4 137 13 127 305 80 0 80 0 7.5 0 7.9 7.4 10/18/2004 14:00:00 15.7 2.8 23.7 9.1 15.3 2.7 23.3 8.8 0.4 0 0.4 0.4 139 13 124 305 81 0 81 0 7.6 0 8.2 7.4 10/18/2004 14:10:00 14.7 2.6 21.8 8.4 14.4 2.5 21.8 8.8 0.4 0 0.4 0.4 140 14 141 305 82 0 82 0 7.5 0 8.2 7.4 10/18/2004 14:20:00 14.6 2.9 24 9.1 14.4 2.8 22.1 8.8 0.4 0 0.4 0.4 140 15 131 305 83 0 83 0 7.3 0.1 7.9 7.2 10/18/2004 14:30:00 13.6 2.4 22.9 7.2 13.5 2.3 21 8.4 0.4 0 0.4 0.4 143 14 143 305 83 0 83 0 7.2 0.2 7.7 7.2 10/18/2004 14:40:00 15 2.9 25.2 8.4 14.9 2.7 22.9 8.4 0.4 0 0.4 0.4 147 13 154 305 83 0 82 0 7.1 0.1 7.7 6.9 10/18/2004 14:50:00 15.2 2.9 22.9 9.1 14.7 2.7 23.3 8.8 0.4 0 0.4 0.4 148 13 155 305 83 0 84 0 7.1 0 7.7 6.9 10/18/2004 15:00:00 13.5 2.9 22.9 7.6 13.6 2.6 21.4 6.1 0.4 0 0.4 0.4 154 13 136 305 83 0 82 0 7 0 7.7 6.9 10/18/2004 15:10:00 14.3 2.5 21 8 15.6 2.6 22.9 9.9 0.4 0 0.4 0.4 161 12 148 305 81 1 81 0 6.9 0 7.4 6.9 10/18/2004 15:20:00 14.9 2.5 21.8 9.9 16.3 2.4 22.1 10.7 0.4 0 0.4 0.4 163 12 156 305 81 0 82 0 6.8 0.1 7.2 6.7 10/18/2004 15:30:00 15.3 2.3 21.4 9.1 17.4 2.2 22.9 10.7 0.4 0 0.4 0.4 165 9 177 305 82 2 82 0 6.8 0.1 7.2 6.7 10/18/2004 15:40:00 14.1 2.5 20.2 8 15.1 2.4 22.1 7.2 0.4 0 0.4 0.4 160 12 150 305 88 0 89 0 6.7 0.1 7.2 6.4 10/18/2004 15:50:00 14.4 2.5 21.4 9.1 15.8 2.6 22.6 7.6 0.4 0 0.4 0.4 163 12 171 305 88 0 88 0 6.5 0.1 6.9 6.4 10/18/2004 16:00:00 13.9 2.2 21 8.4 15.6 2.4 22.9 10.3 0.4 0 0.4 0.4 163 12 156 305 87 0 87 0 6.3 0 6.9 6.1 10/18/2004 16:10:00 14.5 2.2 22.1 8 16 2.2 25.2 10.7 0.4 0 0.4 0.4 163 10 142 305 87 0 87 0 6.2 0 6.7 6.1 10/18/2004 16:20:00 14.6 2.4 23.3 9.5 16.8 2.3 22.9 10.7 0.4 0 0.4 0.4 165 9 154 305 86 0 86 0 6.1 0.1 6.7 5.9 10/18/2004 16:30:00 15.1 2.1 21.8 10.7 17.7 1.9 22.6 12.2 0.4 0 0.4 0.4 165 7 165 305 86 0 85 0 6 0 6.4 5.9 10/18/2004 16:40:00 14.8 2.2 21.8 9.9 18 2.1 24 12.6 0.4 0 0.4 0.4 168 7 160 305 86 0 86 0 6 0 6.4 5.9 10/18/2004 16:50:00 18.7 2.4 24.4 13 19 2.1 25.2 12.6 0.4 0 0.4 0.4 185 7 190 305 85 0 85 0 5.8 0.2 6.4 5.4 10/18/2004 17:00:00 18.9 2.4 26 11.8 18.1 2.3 25.6 13 0.4 0 0.4 0.4 190 5 192 305 85 0 85 0 5.5 0.1 5.9 5.4 10/18/2004 17:10:00 21.8 2.1 26.3 14.9 20.7 2.3 25.6 14.5 0.4 0 0.4 0.4 198 5 185 305 86 0 85 0 5.3 0 5.6 4.9 10/18/2004 17:20:00 20.8 1.9 24.8 16.1 19.9 2.1 24.8 14.1 0.4 0 0.4 0.4 197 5 201 305 86 0 87 0 5 0.1 5.4 4.9 10/18/2004 17:30:00 20.3 2.1 24.4 13.3 19.2 2.3 23.7 13.3 0.4 0 0.4 0.4 195 5 196 305 87 0 87 0 4.9 0 5.4 4.9 10/18/2004 17:40:00 21.9 2.2 26.3 16.1 20.8 2.2 26.8 16.1 0.4 0 0.4 0.4 198 5 196 305 87 0 87 0 4.8 0 5.4 4.7 10/18/2004 17:50:00 21.8 2.4 26.8 16.1 20.9 2.5 27.5 14.1 0.4 0 0.4 0.4 199 5 196 305 87 0 87 0 4.8 0 5.4 4.7 10/18/2004 18:00:00 22.3 2.2 27.5 14.5 21.3 2.4 27.1 13.7 0.4 0 0.4 0.4 202 6 200 305 87 0 87 0 4.8 0 5.4 4.7 10/18/2004 18:10:00 22.5 2.4 27.5 16.8 21.8 2.4 26.3 15.3 0.4 0 0.4 0.4 202 5 194 305 87 0 87 0 4.7 0.1 5.4 4.7 10/18/2004 18:20:00 22.3 1.9 26.3 17.2 21.3 2.2 26.8 15.3 0.4 0 0.4 0.4 201 5 198 305 87 0 87 0 5 0.2 5.6 4.7 10/18/2004 18:30:00 22 2 27.5 16.1 21.1 2.1 26.3 14.9 0.4 0 0.4 0.4 199 5 199 305 87 0 87 0 5.2 0 5.9 4.9 10/18/2004 18:40:00 22.6 2.3 28.7 17.6 21.7 2.5 29.1 15.6 0.4 0 0.4 0.4 200 5 208 305 87 0 87 0 5.4 0.1 5.9 5.2 10/18/2004 18:50:00 22.8 2.1 28.3 17.2 21.7 2.4 27.5 16.1 0.4 0 0.4 0.4 203 6 202 305 87 0 87 0 5.5 0.1 5.9 5.2 10/18/2004 19:00:00 24 2.2 29.4 18.7 23 2.2 28.3 16.4 0.4 0 0.4 0.4 205 5 204 305 87 0 87 0 5.6 0.1 6.1 5.4 10/18/2004 19:10:00 24.1 2.4 29.8 16.8 23.2 2.4 28.7 16.8 0.4 0 0.4 0.4 203 5 212 305 87 0 87 0 5.6 0.1 6.1 5.4 10/18/2004 19:20:00 25.6 2.7 31.3 16.4 24.1 2.9 31.3 16.1 0.4 0 0.4 0.4 206 6 210 305 87 0 87 0 5.7 0 6.1 5.6 10/18/2004 19:30:00 25.5 2.6 30.9 17.2 24.1 2.8 30.2 15.3 0.4 0 0.4 0.4 205 6 210 305 87 0 87 0 5.5 0.1 6.1 5.4 10/18/2004 19:40:00 23.7 2.2 29.1 17.6 22.4 2.4 29.1 16.1 0.4 0 0.4 0.4 205 6 200 305 87 0 87 0 5.5 0.1 5.9 5.4 10/18/2004 19:50:00 24.3 2.4 29.4 16.4 23.1 2.6 28.3 15.3 0.4 0 0.4 0.4 205 5 210 305 87 0 87 0 5.3 0 5.9 5.2 10/18/2004 20:00:00 23.3 2.7 29.4 16.1 21.4 2.8 27.9 14.5 0.4 0 0.4 0.4 207 6 203 305 87 0 87 0 5.3 0 5.9 5.2 10/18/2004 20:10:00 24.4 2.5 29.8 16.8 23 2.7 28.7 16.1 0.4 0 0.4 0.4 206 5 206 305 87 0 87 0 5.5 0.1 5.9 5.4 10/18/2004 20:20:00 25.9 2.4 31.8 19.9 24.6 2.5 31.3 17.2 0.4 0 0.4 0.4 206 5 207 305 88 0 88 0 5.5 0.1 5.9 5.4 10/18/2004 20:30:00 24.8 2.3 29.1 18.3 23.6 2.5 28.3 16.8 0.4 0 0.4 0.4 206 5 203 305 88 0 88 0 5.5 0.1 5.9 5.4 10/18/2004 20:40:00 24 2.8 31.3 16.1 22 3.1 29.4 13 0.4 0 0.4 0.4 208 7 201 305 89 0 88 0 5.3 0.1 5.9 4.9 10/18/2004 20:50:00 25.2 2.7 30.9 16.1 23.5 2.9 30.2 14.1 0.4 0 0.4 0.4 208 6 210 305 89 0 90 0 5 0.2 5.6 4.7 10/18/2004 21:00:00 25 2.7 31.8 16.1 23.1 2.9 29.8 14.9 0.4 0 0.4 0.4 208 6 203 305 90 0 90 0 5.4 0.1 5.9 4.9 10/18/2004 21:10:00 25.5 3.3 32.4 17.6 23.5 3.5 32.4 14.5 0.4 0 0.4 0.4 208 7 208 305 90 0 91 0 5.5 0.1 5.9 5.4 10/18/2004 21:20:00 24.8 2.5 30.2 17.9 23.5 2.6 29.4 16.8 0.4 0 0.4 0.4 206 5 208 305 91 0 91 0 5.5 0.1 5.9 5.4 10/18/2004 21:30:00 26.8 2.8 33.2 17.2 25.2 3.1 32.1 16.1 0.4 0 0.4 0.4 206 6 207 305 91 0 91 0 5.4 0 5.9 5.4 10/18/2004 21:40:00 25.7 3.1 34 17.9 23.9 3.2 33.2 15.6 0.4 0 0.4 0.4 207 6 210 305 91 0 91 0 5.3 0 5.9 5.2 10/18/2004 21:50:00 26.3 2.7 32.1 19.1 24.8 2.8 31.8 17.2 0.4 0 0.4 0.4 205 5 203 305 91 0 91 0 5.2 0 5.6 4.9 10/18/2004 22:00:00 27.1 3.1 33.6 18.7 25.3 3.2 32.9 17.9 0.4 0 0.4 0.4 207 6 216 305 88 3 91 0 5.2 0.2 5.6 4.9 10/18/2004 22:10:00 26.7 2.8 33.2 17.2 25.2 2.9 31.8 16.4 0.4 0 0.4 0.4 207 5 205 305 79 0 82 0 5.1 0.2 5.6 4.9 10/18/2004 22:20:00 26.3 2.9 33.6 17.6 24.3 3.1 31.8 17.6 0.4 0 0.4 0.4 209 6 208 305 79 0 79 0 5.1 0.2 5.6 4.7 10/18/2004 22:30:00 27.5 3.6 35.2 17.9 25.8 4 35.2 15.6 0.4 0 0.4 0.4 207 6 204 305 79 1 79 0 4.8 0.1 5.4 4.7 10/18/2004 22:40:00 26.2 2.8 31.8 17.9 24.6 3.2 30.6 14.5 0.4 0 0.4 0.4 207 5 207 305 81 0 81 0 4.8 0.1 5.6 4.4 10/18/2004 22:50:00 24.4 2.8 30.6 16.1 23 2.9 29.8 14.5 0.4 0 0.4 0.4 206 5 208 305 81 0 81 0 5 0.2 5.4 4.9 10/18/2004 23:00:00 24.3 2.8 29.4 16.1 22.6 3.1 29.1 14.1 0.4 0 0.4 0.4 207 6 218 305 80 0 80 0 4.7 0.1 5.4 4.4 10/18/2004 23:10:00 24.8 2.6 32.1 17.2 23.4 2.8 30.9 15.6 0.4 0 0.4 0.4 208 6 206 305 80 0 80 0 4.2 0.2 4.7 3.9 10/18/2004 23:20:00 22.8 2.6 28.3 15.6 20.9 2.8 26.8 13.7 0.4 0 0.4 0.4 208 7 218 305 80 0 80 0 4.4 0.3 4.9 3.9 10/18/2004 23:30:00 25.1 2.8 31.3 19.1 23.1 2.9 30.2 16.4 0.4 0 0.4 0.4 209 6 210 305 80 0 80 0 4.5 0.2 5.2 4.2 10/18/2004 23:40:00 24.8 2.8 31.8 17.9 22.7 2.9 29.8 14.9 0.4 0 0.4 0.4 210 6 214 305 80 0 80 0 4 0.2 4.7 3.7 10/18/2004 23:50:00 23.9 2.5 30.2 17.6 21.8 2.7 28.3 15.3 0.4 0 0.4 0.4 210 7 206 305 79 0 79 0 4.4 0.1 4.9 4.2 10/19/2004 00:00:00 24 2.6 28.7 16.8 22.1 2.9 28.7 13.3 0.4 0 0.4 0.4 209 6 205 305 79 0 79 0 4.5 0.1 4.9 4.4 10/19/2004 00:10:00 24.1 2.5 29.8 16.8 22.1 2.7 28.3 15.3 0.4 0 0.4 0.4 208 7 207 305 79 0 79 0 4.5 0.2 4.9 4.4 10/19/2004 00:20:00 23.3 2.6 29.1 15.6 21.6 2.8 28.7 14.5 0.4 0 0.4 0.4 210 6 207 305 80 2 78 0 4.5 0.1 4.9 4.4 10/19/2004 00:30:00 23.7 3.2 29.8 14.9 22 3.2 29.1 14.9 0.4 0 0.4 0.4 209 7 215 305 81 0 82 0 4.5 0.1 4.9 4.2 10/19/2004 00:40:00 24 3.1 31.8 16.8 22.4 3.1 30.2 14.9 0.4 0 0.4 0.4 211 7 205 305 80 0 80 0 4 0.1 4.7 3.9 10/19/2004 00:50:00 22.7 2.8 28.7 14.1 21 3.1 27.1 13 0.4 0 0.4 0.4 209 6 205 305 80 0 80 0 4 0.1 4.7 3.7 10/19/2004 01:00:00 22.3 2.7 28.3 14.9 20.8 2.9 27.9 13.7 0.4 0 0.4 0.4 211 6 222 305 80 0 80 0 4.2 0.2 4.9 3.9 10/19/2004 01:10:00 21.5 2.4 27.5 14.1 19.6 2.6 26 12.6 0.4 0 0.4 0.4 210 6 215 305 79 0 80 0 3.7 0.2 4.7 3.2 10/19/2004 01:20:00 20.9 2.2 26.3 14.5 19.5 2.3 24.8 13.3 0.4 0 0.4 0.4 212 6 221 305 79 0 79 0 3.9 0.2 4.7 3.7 10/19/2004 01:30:00 21.2 3.1 29.4 15.3 19.9 3.2 29.4 13.7 0.4 0 0.4 0.4 215 11 208 305 79 0 79 0 4 0.2 4.7 3.7 10/19/2004 01:40:00 23.6 2.7 30.2 16.1 22.1 2.8 28.3 15.6 0.4 0 0.4 0.4 213 7 214 305 79 0 79 0 3.7 0.2 4.4 3.4 10/19/2004 01:50:00 23.2 2.4 27.9 14.9 21.9 2.7 27.1 13.3 0.4 0 0.4 0.4 215 6 218 305 78 0 78 0 3.8 0.1 4.4 3.7 10/19/2004 02:00:00 23.6 2.4 29.1 17.6 22.3 2.5 27.9 16.4 0.4 0 0.4 0.4 217 6 215 305 77 0 77 0 3.9 0.2 4.4 3.7 10/19/2004 02:10:00 24.3 2.7 30.2 16.4 22.9 2.8 29.4 16.4 0.4 0 0.4 0.4 215 5 221 305 77 0 77 0 3.6 0.3 4.4 3.2 10/19/2004 02:20:00 23.4 2.1 29.1 17.2 22.1 2.5 29.1 14.1 0.4 0 0.4 0.4 216 5 221 305 76 0 76 0 3.6 0.2 4.4 3.2 10/19/2004 02:30:00 22.6 2 27.5 16.1 21.5 2.1 27.1 16.4 0.4 0 0.4 0.4 216 5 219 305 76 0 76 0 3.9 0.2 4.4 3.7 10/19/2004 02:40:00 22.8 2 27.5 16.1 21.7 2.2 26.8 15.6 0.4 0 0.4 0.4 217 5 220 305 76 0 76 0 4 0.2 4.4 3.7 10/19/2004 02:50:00 22.5 2.6 29.4 15.3 21 2.7 29.4 14.1 0.4 0 0.4 0.4 220 6 220 305 76 0 76 0 4 0.2 4.7 3.9 10/19/2004 03:00:00 21.9 1.9 26 16.4 20.6 2.2 25.2 14.9 0.4 0 0.4 0.4 217 5 224 305 77 0 77 0 4 0.2 4.4 3.7 10/19/2004 03:10:00 22 1.8 27.1 15.6 20.7 2.1 25.2 15.3 0.4 0 0.4 0.4 216 5 221 305 78 0 78 0 3.9 0.2 4.4 3.7 10/19/2004 03:20:00 21.4 2.6 26 12.6 20.2 2.6 25.6 12.2 0.4 0 0.4 0.4 213 5 217 305 79 0 79 0 3.8 0.1 4.4 3.7 10/19/2004 03:30:00 21.3 2.3 25.6 14.5 19.9 2.5 25.6 12.2 0.4 0 0.4 0.4 215 5 208 305 80 0 80 0 3.9 0.2 4.4 3.7 10/19/2004 03:40:00 22.7 2.4 27.5 16.4 21.2 2.7 26.8 14.5 0.4 0 0.4 0.4 215 7 218 305 81 0 81 0 4 0.2 4.7 3.7 10/19/2004 03:50:00 22.3 2.1 27.1 16.4 21 2.3 26.3 14.9 0.4 0 0.4 0.4 217 7 224 305 82 0 83 0 4 0.2 4.4 3.7 10/19/2004 04:00:00 21.6 2.1 27.9 15.6 20.3 2.5 26.8 13.3 0.4 0 0.4 0.4 215 6 218 305 84 1 83 0 3.9 0.2 4.7 3.7 10/19/2004 04:10:00 23.2 2.3 29.1 14.9 21.8 2.4 27.5 13.7 0.4 0 0.4 0.4 214 5 210 305 84 0 84 0 4 0.1 4.7 3.9 10/19/2004 04:20:00 22.8 2.5 28.3 17.2 21.6 2.6 27.9 15.6 0.4 0 0.4 0.4 217 6 214 305 84 0 84 0 4.2 0.1 4.7 4.2 10/19/2004 04:30:00 23.7 2.4 29.4 16.4 22.2 2.6 28.7 15.6 0.4 0 0.4 0.4 219 5 210 305 83 0 82 0 4.3 0.1 4.7 4.2 10/19/2004 04:40:00 22.9 3.1 29.4 14.1 21.7 2.9 29.8 14.1 0.4 0 0.4 0.4 219 6 215 305 81 0 82 0 4.3 0 4.9 4.2 10/19/2004 04:50:00 23.7 2.4 29.8 17.6 22.4 2.7 29.8 15.6 0.4 0 0.4 0.4 218 6 218 305 79 0 79 0 4.2 0.1 4.7 4.2 10/19/2004 05:00:00 23.2 2.4 28.7 17.2 21.8 2.5 27.9 15.6 0.4 0 0.4 0.4 216 6 213 305 78 0 77 0 4.1 0.1 4.7 3.9 10/19/2004 05:10:00 22.9 1.7 27.1 18.7 21.7 2.1 26.3 15.3 0.4 0 0.4 0.4 217 5 224 305 76 0 76 0 3.9 0.1 4.4 3.7 10/19/2004 05:20:00 21.2 2.3 27.1 13.7 19.8 2.3 24.8 13.3 0.4 0 0.4 0.4 221 6 211 305 79 2 80 0 3.9 0.1 4.4 3.7 10/19/2004 05:30:00 23.1 2.7 29.8 15.6 21.5 2.9 27.1 14.9 0.4 0 0.4 0.4 224 6 225 305 79 0 79 0 3.9 0.2 4.4 3.4 10/19/2004 05:40:00 22.8 2.9 29.8 15.3 21.5 3.1 28.7 15.3 0.4 0 0.4 0.4 227 6 224 305 77 0 77 0 3.2 0.1 3.9 2.9 10/19/2004 05:50:00 20.6 1.9 25.2 14.5 19.4 2.2 25.2 13.3 0.4 0 0.4 0.4 222 7 226 305 75 0 76 0 3.6 0 4.2 3.2 10/19/2004 06:00:00 20.8 2.5 27.9 14.5 19.5 2.6 25.6 13.3 0.4 0 0.4 0.4 227 6 236 305 74 0 74 0 3.2 0.1 3.7 2.9 10/19/2004 06:10:00 20.8 2.4 25.6 14.5 19.4 2.6 24.4 12.6 0.4 0 0.4 0.4 227 6 224 305 73 0 73 0 2.8 0.3 3.7 2.5 10/19/2004 06:20:00 22 2.4 27.9 15.6 20.4 2.7 26.3 13.7 0.4 0 0.4 0.4 227 6 228 305 73 0 73 0 3.2 0.2 3.9 2.7 10/19/2004 06:30:00 20.9 2.7 26 14.9 19.5 2.7 25.6 12.6 0.4 0 0.4 0.4 224 6 220 305 74 0 74 0 3.6 0.1 4.2 3.4 10/19/2004 06:40:00 21.9 2.4 27.5 16.1 20.4 2.4 25.6 14.5 0.4 0 0.4 0.4 226 6 227 305 72 1 72 0 3.4 0.2 4.2 3.2 10/19/2004 06:50:00 22.7 2.6 28.7 15.6 21.4 2.7 27.9 14.5 0.4 0 0.4 0.4 232 6 231 305 70 1 70 0 2.9 0.5 4.2 2 10/19/2004 07:00:00 22.1 2.8 28.7 14.5 20.7 2.7 27.5 14.9 0.4 0 0.4 0.4 228 6 229 305 69 0 69 0 2.5 0.2 3.2 2 10/19/2004 07:10:00 20.9 2.6 26.8 14.1 19.8 2.7 25.2 13 0.4 0 0.4 0.4 228 6 232 305 68 0 68 0 3.2 0.3 3.9 2.7 10/19/2004 07:20:00 22.2 2.8 28.7 13.3 20.6 2.8 27.5 13 0.4 0 0.4 0.4 226 6 231 305 66 1 66 0 3.7 0 4.2 3.4 10/19/2004 07:30:00 22.9 2.6 27.5 14.5 21.5 2.8 27.5 13.3 0.4 0 0.4 0.4 227 5 228 305 64 0 64 0 3.7 0.1 4.4 3.4 10/19/2004 07:40:00 22.9 2.1 27.1 15.6 21.3 2.3 26.8 14.5 0.4 0 0.4 0.4 229 6 222 305 62 0 63 0 3.1 0.4 4.2 2.7 10/19/2004 07:50:00 23.5 2.2 29.1 17.9 22.1 2.3 26.8 14.9 0.4 0 0.4 0.4 230 6 234 305 59 1 62 0 3.5 0.2 4.4 3.2 10/19/2004 08:00:00 22.5 2.4 27.1 16.4 21.2 2.7 27.5 15.3 0.4 0 0.4 0.4 227 6 227 305 58 2 57 0 3.9 0.1 4.4 3.7 10/19/2004 08:10:00 22 2.3 26.8 14.9 20.6 2.5 26.3 14.5 0.4 0 0.4 0.4 226 7 224 305 62 0 63 0 3.6 0.2 4.4 3.2 10/19/2004 08:20:00 23.8 3.2 30.6 16.4 22.4 3.3 30.6 15.6 0.4 0 0.4 0.4 229 6 236 305 61 0 60 0 3.7 0.1 4.4 3.4 10/19/2004 08:30:00 23.8 2.2 29.4 17.6 22.5 2.3 29.1 15.6 0.4 0 0.4 0.4 229 6 231 305 61 0 60 0 3.8 0.1 4.4 3.7 10/19/2004 08:40:00 24.3 2.7 29.8 16.4 22.9 2.8 28.7 15.6 0.4 0 0.4 0.4 231 5 234 305 59 1 59 0 3.8 0 4.4 3.7 10/19/2004 08:50:00 22.3 2.6 27.9 16.1 20.9 2.7 28.3 14.1 0.4 0 0.4 0.4 229 6 235 305 58 0 58 0 3.6 0.2 4.4 3.2 10/19/2004 09:00:00 20.3 2.8 28.3 13.7 18.8 2.8 26 12.2 0.4 0 0.4 0.4 225 6 225 305 57 1 56 0 3.5 0 3.9 3.2 10/19/2004 09:10:00 22.6 2.4 27.5 14.1 21 2.6 27.5 13.7 0.4 0 0.4 0.4 228 7 228 305 58 0 59 0 3.1 0.2 3.9 2.7 10/19/2004 09:20:00 22.9 2.1 29.1 17.6 21.4 2.4 28.3 15.6 0.4 0 0.4 0.4 228 6 224 305 56 0 56 0 3.3 0 3.7 3.2 10/19/2004 09:30:00 20.3 1.5 24.4 15.6 19.1 1.8 23.7 14.5 0.4 0 0.4 0.4 232 5 235 305 54 1 55 0 3.5 0 3.9 3.2 10/19/2004 09:40:00 21.2 2.8 26 14.1 19.8 2.8 25.6 11.8 0.4 0 0.4 0.4 227 6 228 305 52 1 52 0 3.8 0.1 4.4 3.4 10/19/2004 09:50:00 22 2.5 26.8 16.1 20.6 2.6 26.8 13.3 0.4 0 0.4 0.4 227 6 229 305 53 4 49 0 4 0.1 4.4 3.7 10/19/2004 10:00:00 23 2.4 28.3 16.1 21.4 2.6 27.5 14.5 0.4 0 0.4 0.4 225 6 221 305 59 2 60 0 3.9 0 4.4 3.7 10/19/2004 10:10:00 21.3 2.9 27.5 14.1 19.8 3.2 27.1 13.3 0.4 0 0.4 0.4 227 6 224 305 45 13 61 0 4 0.1 4.7 3.7 10/19/2004 10:20:00 21.7 2.3 26.3 14.5 20.2 2.3 26 14.5 0.4 0 0.4 0.4 223 6 216 305 27 2 26 0 4 0.2 4.4 3.9 10/19/2004 10:30:00 21.6 2.5 26.8 14.5 20.3 2.6 26 13.7 0.4 0 0.4 0.4 225 5 218 305 21 1 24 0 3.9 0.1 4.4 3.7 10/19/2004 10:40:00 20.3 2.2 24.8 14.9 18.9 2.4 24.4 12.2 0.4 0 0.4 0.4 226 6 231 305 19 0 20 0 4 0.1 4.4 3.9 10/19/2004 10:50:00 20.8 2.1 25.2 14.1 19.3 2.2 24 13 0.4 0 0.4 0.4 224 6 227 305 18 1 18 0 4 0 4.4 3.9 10/19/2004 11:00:00 21.3 2.3 26.3 14.5 19.9 2.4 24.8 13 0.4 0 0.4 0.4 225 6 227 305 17 1 18 0 4.1 0.1 4.4 3.9 10/19/2004 11:10:00 19.1 2 24 13 17.7 2.1 23.3 12.6 0.4 0 0.4 0.4 225 6 231 305 15 1 18 0 4.2 0 4.7 4.2 10/19/2004 11:20:00 19.6 1.8 24 13.7 18.3 2.1 23.3 12.6 0.4 0 0.4 0.4 223 5 232 305 13 0 14 0 4.4 0 4.9 4.2 10/19/2004 11:30:00 19.9 1.9 24.8 14.5 18.6 2.1 22.9 13.3 0.4 0 0.4 0.4 220 6 225 305 3 2 3 0 4.3 0.1 4.9 4.2 10/19/2004 11:40:00 17.1 2 22.1 12.2 15.9 2.1 21 11.1 0.4 0 0.4 0.4 214 7 222 305 3 0 3 0 4 0.2 4.7 3.7 10/19/2004 11:50:00 16.4 1.8 20.6 11.1 15.2 1.9 19.1 10.3 0.4 0 0.4 0.4 211 6 212 305 3 0 3 0 3.7 0.1 4.2 3.4 10/19/2004 12:00:00 18.5 2 22.6 11.8 17.3 2.2 22.6 11.1 0.4 0 0.4 0.4 216 6 219 305 3 0 2 0 3.6 0.2 4.2 3.4 10/19/2004 12:10:00 19.8 1.7 24.8 14.5 18.7 2 24 12.2 0.4 0 0.4 0.4 215 5 217 305 3 0 3 0 3.3 0.2 3.9 3.2 10/19/2004 12:20:00 21 2.4 26.8 15.6 19.9 2.5 26.8 13.7 0.4 0 0.4 0.4 217 5 215 305 3 0 3 0 2.9 0.5 4.2 2.2 10/19/2004 12:30:00 19.1 1.5 22.6 14.1 18.2 1.7 22.1 13.3 0.4 0 0.4 0.4 217 5 223 305 3 0 2 0 2.9 0.4 3.7 2.2 10/19/2004 12:40:00 18.7 2.5 23.7 12.6 17.6 2.6 22.9 11.8 0.4 0 0.4 0.4 217 5 219 305 3 0 3 0 3.6 0.2 4.4 3.2 10/19/2004 12:50:00 18.3 2.6 25.2 12.6 17.2 2.6 24.4 12.2 0.4 0 0.4 0.4 221 5 231 305 2 0 1 0 3.9 0.2 4.4 3.4 10/19/2004 13:00:00 20 2 25.2 13 18.8 2.4 24.8 11.8 0.4 0 0.4 0.4 216 5 221 305 1 0 1 0 3.5 0.1 4.2 3.2 10/19/2004 13:10:00 20.4 2.2 26 15.3 19.2 2.5 24.8 13 0.4 0 0.4 0.4 217 6 218 305 1 0 0 0 3.4 0.1 4.2 3.2 10/19/2004 13:20:00 19.2 2.1 24 14.1 18.1 2.1 22.9 13.3 0.4 0 0.4 0.4 221 6 217 305 0 0 0 0 3.3 0.1 3.9 3.2 10/19/2004 13:30:00 18.9 1.7 22.9 13 17.7 1.7 22.6 13 0.4 0 0.4 0.4 220 5 219 305 0 0 0 0 3.4 0.1 3.7 3.2 10/19/2004 13:40:00 17.9 2.3 22.9 11.5 16.9 2.5 22.6 10.7 0.4 0 0.4 0.4 210 7 207 305 0 0 0 0 3.9 0.2 4.4 3.4 10/19/2004 13:50:00 20 2.3 23.7 12.2 18.8 2.4 23.3 10.3 0.4 0 0.4 0.4 208 5 206 305 0 0 0 0 3.8 0 4.2 3.7 10/19/2004 14:00:00 19.8 2.7 25.2 12.2 18.1 2.8 24.4 9.5 0.4 0 0.4 0.4 212 6 211 305 0 0 0 0 3.9 0.1 4.4 3.7 10/19/2004 14:10:00 20.1 2.3 26 13.7 18.5 2.4 25.2 11.8 0.4 0 0.4 0.4 212 6 211 305 0 0 0 0 4 0 4.4 3.9 10/19/2004 14:20:00 20.4 2.2 24.4 14.1 18.6 2.4 23.3 12.2 0.4 0 0.4 0.4 212 6 215 305 0 0 0 0 4.2 0 4.7 3.9 10/19/2004 14:30:00 20.4 2.4 24.8 12.6 18.9 2.6 24.4 12.2 0.4 0 0.4 0.4 212 6 210 305 0 0 0 0 4.3 0 4.7 4.2 10/19/2004 14:40:00 20.9 2.4 25.6 14.1 19.6 2.6 25.2 12.6 0.4 0 0.4 0.4 214 6 216 305 0 0 0 0 4.4 0.1 4.9 4.2 10/19/2004 14:50:00 21.2 2.3 25.6 14.5 19.7 2.4 25.6 13.3 0.4 0 0.4 0.4 212 6 218 305 0 0 0 0 4.4 0 4.9 4.4 10/19/2004 15:00:00 20.5 2.4 25.6 13.3 18.9 2.6 24 12.2 0.4 0 0.4 0.4 211 7 213 305 0 0 0 0 4.5 0.1 4.9 4.4 10/19/2004 15:10:00 19.1 2.5 24.4 12.2 17.6 2.7 23.7 10.7 0.4 0 0.4 0.4 211 6 214 305 0 0 0 0 4.4 0.1 4.9 4.4 10/19/2004 15:20:00 19.8 2.7 24.8 11.8 18.6 2.8 25.2 12.2 0.4 0 0.4 0.4 212 7 213 305 0 0 0 0 4.4 0 4.9 4.4 10/19/2004 15:30:00 21 2.4 26.3 14.1 19.2 2.4 24 12.2 0.4 0 0.4 0.4 211 5 220 305 0 0 0 0 4.4 0 4.9 4.2 10/19/2004 15:40:00 19.2 2.1 23.7 13 17.7 2.4 22.9 11.8 0.4 0 0.4 0.4 210 7 207 305 0 0 0 0 4.2 0 4.7 4.2 10/19/2004 15:50:00 19 2.3 24.8 13 17.7 2.5 24.8 10.7 0.4 0 0.4 0.4 210 7 224 305 0 0 0 0 4.3 0 4.7 4.2 10/19/2004 16:00:00 18.2 2.3 24 10.3 16.9 2.3 23.3 9.9 0.4 0 0.4 0.4 212 7 208 305 0 0 0 0 4.4 0.1 4.9 4.2 10/19/2004 16:10:00 18.7 2.4 23.3 11.8 17.5 2.5 22.6 11.8 0.4 0 0.4 0.4 212 6 217 305 0 0 0 0 4.4 0.1 4.9 4.2 10/19/2004 16:20:00 17.1 2.3 21.8 12.2 15.6 2.5 21 10.7 0.4 0 0.4 0.4 210 6 212 305 0 0 0 0 4.3 0 4.9 4.2 10/19/2004 16:30:00 18.7 2.6 26.3 12.6 17.5 2.7 24.4 11.1 0.4 0 0.4 0.4 212 6 217 305 0 0 0 0 3.8 0.5 4.7 2.5 10/19/2004 16:40:00 18.1 1.9 22.6 12.6 17.1 2 21.8 11.1 0.4 0 0.4 0.4 208 6 214 305 0 0 0 0 2.8 0.1 3.4 2.5 10/19/2004 16:50:00 17 2 21.8 11.5 15.4 2.2 20.6 8.8 0.4 0 0.4 0.4 210 7 217 305 0 0 0 0 3.3 0.2 4.2 2.9 10/19/2004 17:00:00 16.8 1.9 20.6 11.5 15.9 2.1 19.9 10.3 0.4 0 0.4 0.4 208 6 213 305 0 0 0 0 3.9 0.2 4.4 3.4 10/19/2004 17:10:00 16.3 1.7 20.2 11.5 15.1 1.9 19.5 9.5 0.4 0 0.4 0.4 209 6 207 305 0 0 0 0 4.1 0.2 4.4 3.9 10/19/2004 17:20:00 17 1.9 22.1 10.7 15.8 2 19.9 11.1 0.4 0 0.4 0.4 209 6 218 305 0 0 0 0 4.2 0.2 4.7 3.9 10/19/2004 17:30:00 16.2 1.8 20.6 10.7 15.1 2 20.2 9.9 0.4 0 0.4 0.4 208 7 210 305 0 0 0 0 4.3 0.2 4.7 4.2 10/19/2004 17:40:00 18.2 2 23.3 13.3 17.2 2.2 21.8 11.1 0.4 0 0.4 0.4 210 7 214 305 0 0 0 0 4 0.4 4.7 2.9 10/19/2004 17:50:00 16.7 1.9 22.1 10.7 15.5 2 20.2 9.5 0.4 0 0.4 0.4 212 6 214 305 0 0 0 0 3.4 0.1 4.2 2.9 10/19/2004 18:00:00 16.2 1.7 20.2 11.8 15.1 1.8 19.9 10.3 0.4 0 0.4 0.4 213 8 216 305 0 0 0 0 3.7 0.1 4.4 3.4 10/19/2004 18:10:00 18.4 2.9 24.8 12.2 17.2 3.1 24.8 10.3 0.4 0 0.4 0.4 213 7 216 305 0 0 0 0 3.2 0.5 4.4 2.7 10/19/2004 18:20:00 18.5 1.7 21.8 13.7 17.5 1.9 21.8 12.2 0.4 0 0.4 0.4 217 6 212 305 0 0 0 0 3.4 0.1 3.9 3.2 10/19/2004 18:30:00 15.5 1.7 19.1 10.3 14.5 1.8 18.3 9.1 0.4 0 0.4 0.4 224 8 216 305 0 0 0 0 3.1 0.1 3.7 2.9 10/19/2004 18:40:00 16.1 1.7 19.9 10.7 15.2 1.8 19.1 11.1 0.4 0 0.4 0.4 218 5 210 305 0 0 0 0 3.3 0.1 3.9 2.9 10/19/2004 18:50:00 15.2 1.5 19.1 10.7 14.3 1.5 18.3 10.3 0.4 0 0.4 0.4 209 6 215 305 0 0 0 0 3.1 0.3 3.7 2.7 10/19/2004 19:00:00 14.1 1.5 17.6 9.1 13.1 1.7 17.6 8.8 0.4 0 0.4 0.4 210 6 205 305 0 0 0 0 3.1 0.1 3.7 2.7 10/19/2004 19:10:00 14.1 1.5 17.6 9.5 13.2 1.7 17.2 8.4 0.4 0 0.4 0.4 210 6 209 305 0 0 0 0 3.3 0 3.7 3.2 10/19/2004 19:20:00 14.1 1.4 17.2 9.9 13.4 1.5 16.8 8.4 0.4 0 0.4 0.4 207 6 212 305 0 0 0 0 3.2 0 3.7 2.9 10/19/2004 19:30:00 15.1 1.7 18.7 9.5 14 1.8 19.1 9.5 0.4 0 0.4 0.4 210 6 208 305 0 0 0 0 3.3 0 3.7 3.2 10/19/2004 19:40:00 15 1.8 19.9 10.7 13.9 1.8 19.5 9.1 0.4 0 0.4 0.4 226 7 217 305 0 0 0 0 2.2 0.6 3.7 1.5 10/19/2004 19:50:00 13.7 1 16.4 10.3 13.1 1.1 16.4 9.5 0.4 0 0.4 0.4 215 4 211 305 0 0 0 0 1.7 0.1 2.5 1.5 10/19/2004 20:00:00 13.2 1.5 16.4 9.1 12.2 1.6 16.1 8 0.4 0 0.4 0.4 212 6 210 305 0 0 0 0 2.4 0.1 3.2 2.2 10/19/2004 20:10:00 13 1.2 15.3 8 12.4 1.5 14.9 7.6 0.4 0 0.4 0.4 208 5 205 305 0 0 0 0 2.6 0 2.9 2.5 10/19/2004 20:20:00 14.2 1.3 17.2 10.3 13.4 1.4 16.4 8.8 0.4 0 0.4 0.4 219 6 218 305 0 0 0 0 2.7 0 3.2 2.5 10/19/2004 20:30:00 13.9 1.5 17.2 9.5 13.3 1.6 16.8 8.8 0.4 0 0.4 0.4 218 4 216 305 0 0 0 0 2.3 0.1 2.7 2.2 10/19/2004 20:40:00 11.9 1.3 14.5 8 11.3 1.4 14.1 7.6 0.4 0 0.4 0.4 221 5 223 305 0 0 0 0 2.6 0 3.2 2.2 10/19/2004 20:50:00 12.6 1.3 16.1 9.1 11.8 1.4 15.3 7.6 0.4 0 0.4 0.4 221 5 217 305 0 0 0 0 2.7 0 3.2 2.5 10/19/2004 21:00:00 11 1.2 13 6.8 10.3 1.3 13.3 6.8 0.4 0 0.4 0.4 212 6 215 305 0 0 0 0 2.5 0 3.2 2.5 10/19/2004 21:10:00 10.7 1 13.7 8 10 1.2 13.7 7.2 0.4 0 0.4 0.4 216 6 217 305 0 0 0 0 2.6 0 2.9 2.5 10/19/2004 21:20:00 12 1.2 14.9 8.8 11.3 1.3 14.1 8 0.4 0 0.4 0.4 221 5 220 305 0 0 0 0 2.8 0.1 3.4 2.7 10/19/2004 21:30:00 11.5 1.3 15.3 8 10.7 1.5 14.9 7.2 0.4 0 0.4 0.4 223 5 225 305 0 0 0 0 2.9 0 3.4 2.9 10/19/2004 21:40:00 12.3 1 14.5 9.1 11.5 1.2 14.1 8 0.4 0 0.4 0.4 225 5 212 305 0 0 0 0 2.9 0 3.4 2.9 10/19/2004 21:50:00 13.2 0.9 15.6 10.3 12.5 1.1 15.3 9.5 0.4 0 0.4 0.4 221 4 222 305 0 0 0 0 3 0 3.4 2.9 10/19/2004 22:00:00 13.6 1.1 16.1 9.9 12.8 1.2 15.3 8.4 0.4 0 0.4 0.4 224 9 223 305 0 0 0 0 3.1 0 3.4 2.7 10/19/2004 22:10:00 12.8 1.7 17.2 8.4 12.1 1.7 16.4 8 0.4 0 0.4 0.4 232 9 245 305 0 0 0 0 2 0.3 3.2 1.5 10/19/2004 22:20:00 13 1.9 16.4 8.8 12.1 1.7 15.6 7.6 0.4 0 0.4 0.4 223 6 224 305 0 0 0 0 2.7 0 3.2 2.5 10/19/2004 22:30:00 13.4 1.2 16.1 9.5 12.6 1.4 16.1 8.8 0.4 0 0.4 0.4 227 5 231 305 0 0 0 0 2.6 0 3.2 2.2 10/19/2004 22:40:00 13.9 1.2 16.1 10.7 13 1.3 15.6 9.5 0.4 0 0.4 0.4 224 5 225 305 0 0 0 0 2.3 0 2.7 2.2 10/19/2004 22:50:00 13.4 1.6 17.9 9.1 12.6 1.7 17.6 8.8 0.4 0 0.4 0.4 232 6 230 305 0 0 0 0 1.8 0.2 2.5 1.5 10/19/2004 23:00:00 11.6 1.2 14.1 7.6 10.9 1.3 14.1 7.2 0.4 0 0.4 0.4 225 5 230 305 0 0 0 0 1.9 0.2 2.5 1.5 10/19/2004 23:10:00 13 1.7 17.6 8.4 12.1 1.7 16.1 8.4 0.4 0 0.4 0.4 226 8 232 305 0 0 0 0 2.3 0.1 2.9 2 10/19/2004 23:20:00 13.2 1.3 17.2 9.1 12.4 1.5 16.4 9.1 0.4 0 0.4 0.4 224 6 233 305 0 0 0 0 1.7 0.2 2.5 1.5 10/19/2004 23:30:00 13.3 1.3 16.1 9.1 12.4 1.4 15.3 7.6 0.4 0 0.4 0.4 222 7 215 305 0 0 0 0 2.3 0 2.9 2.2 10/19/2004 23:40:00 14.2 1 16.8 11.8 13.5 1.2 16.4 9.5 0.4 0 0.4 0.4 217 4 220 305 0 0 0 0 2.2 0 2.7 2 10/19/2004 23:50:00 13.5 1.2 15.6 10.3 12.6 1.3 15.6 9.1 0.4 0 0.4 0.4 224 7 227 305 0 0 0 0 2.4 0 2.9 2.2 10/20/2004 00:00:00 14.5 1.3 17.2 9.5 13.4 1.5 16.4 9.5 0.4 0 0.4 0.4 227 5 227 305 0 0 0 0 2.6 0 2.9 2.5 10/20/2004 00:10:00 13.7 1.3 16.1 9.5 12.9 1.6 16.1 8.8 0.4 0 0.4 0.4 222 5 224 305 0 0 0 0 2.7 0 3.2 2.5 10/20/2004 00:20:00 15.1 1.2 17.6 11.8 14.2 1.3 17.2 11.1 0.4 0 0.4 0.4 228 5 231 305 0 0 0 0 2.9 0 3.4 2.7 10/20/2004 00:30:00 13.4 1.5 16.4 9.5 12.6 1.7 16.1 8.4 0.4 0 0.4 0.4 226 5 229 305 0 0 0 0 2.9 0.1 3.4 2.7 10/20/2004 00:40:00 14.2 1.4 16.4 9.5 13.2 1.5 16.1 8.8 0.4 0 0.4 0.4 229 5 228 305 0 0 0 0 2.9 0.1 3.4 2.7 10/20/2004 00:50:00 14 1.3 17.6 10.7 13.2 1.4 16.8 8.8 0.4 0 0.4 0.4 231 5 234 305 0 0 0 0 2.9 0.1 3.4 2.7 10/20/2004 01:00:00 13.9 1 16.4 10.7 12.9 1.2 16.1 8.8 0.4 0 0.4 0.4 228 5 231 305 0 0 0 0 2.9 0 3.4 2.7 10/20/2004 01:10:00 13.7 1.5 16.8 9.5 12.8 1.6 16.1 8.8 0.4 0 0.4 0.4 233 5 234 305 0 0 0 0 2.9 0.1 3.4 2.7 10/20/2004 01:20:00 14 1.4 17.9 11.1 12.9 1.5 17.2 9.9 0.4 0 0.4 0.4 229 6 227 305 0 0 0 0 2.9 0.1 3.4 2.7 10/20/2004 01:30:00 14.3 1.4 17.2 10.7 13.4 1.4 16.4 9.5 0.4 0 0.4 0.4 230 5 224 305 0 0 0 0 2.8 0.1 3.2 2.7 10/20/2004 01:40:00 13.4 1.3 16.1 10.3 12.4 1.4 16.1 9.1 0.4 0 0.4 0.4 229 5 228 305 0 0 0 0 2.8 0.1 3.4 2.7 10/20/2004 01:50:00 13.9 1.2 16.4 10.3 13 1.3 16.4 9.1 0.4 0 0.4 0.4 228 5 222 305 0 0 0 0 2.8 0.1 3.4 2.7 10/20/2004 02:00:00 13.8 1.3 16.8 9.5 12.9 1.5 16.4 8.4 0.4 0 0.4 0.4 233 5 231 305 0 0 0 0 2.9 0.1 3.4 2.7 10/20/2004 02:10:00 13.4 1 15.3 10.3 12.5 1.2 14.9 9.1 0.4 0 0.4 0.4 230 6 235 305 0 0 0 0 2.9 0.1 3.4 2.7 10/20/2004 02:20:00 13.9 1.3 16.4 10.7 12.9 1.5 16.4 8.8 0.4 0 0.4 0.4 233 5 234 305 0 0 0 0 2.8 0.1 3.4 2.7 10/20/2004 02:30:00 13.5 1.1 15.6 9.5 12.6 1.2 15.3 9.1 0.4 0 0.4 0.4 231 5 229 305 0 0 0 0 2.8 0.1 3.2 2.7 10/20/2004 02:40:00 13.5 1.5 16.4 9.1 12.6 1.6 16.4 8.4 0.4 0 0.4 0.4 227 5 226 305 0 0 0 0 2.8 0.1 3.2 2.7 10/20/2004 02:50:00 14.1 1.3 16.4 9.9 13.2 1.4 16.4 9.1 0.4 0 0.4 0.4 227 5 230 305 0 0 0 0 2.8 0.1 3.2 2.7 10/20/2004 03:00:00 13.4 1.2 16.1 9.9 12.5 1.3 15.3 8.8 0.4 0 0.4 0.4 228 5 220 305 0 0 0 0 2.6 0 3.2 2.5 10/20/2004 03:10:00 13.3 1.2 16.1 9.9 12.6 1.4 16.4 8.4 0.4 0 0.4 0.4 232 4 229 305 0 0 0 0 2.6 0 2.9 2.5 10/20/2004 03:20:00 13.6 1.1 16.4 9.9 12.7 1.3 15.3 9.1 0.4 0 0.4 0.4 232 5 234 305 0 0 0 0 2.6 0 3.2 2.5 10/20/2004 03:30:00 12.2 1.1 14.5 9.1 11.5 1.2 14.5 8.8 0.4 0 0.4 0.4 230 6 229 305 0 0 0 0 2.6 0 3.2 2.5 10/20/2004 03:40:00 12.6 1.3 15.3 8.4 11.8 1.5 14.9 8 0.4 0 0.4 0.4 232 6 232 305 0 0 0 0 2.7 0 3.2 2.5 10/20/2004 03:50:00 13.7 1 15.6 9.9 12.9 1.1 15.3 9.9 0.4 0 0.4 0.4 233 5 235 305 0 0 0 0 2.6 0 2.9 2.5 10/20/2004 04:00:00 13 1.3 15.6 8.8 12.2 1.4 15.6 8 0.4 0 0.4 0.4 226 4 227 305 0 0 0 0 2.5 0 2.9 2.2 10/20/2004 04:10:00 12 1.2 14.9 8.8 11.2 1.4 14.5 8 0.4 0 0.4 0.4 228 6 218 305 0 0 0 0 2.6 0 3.2 2.2 10/20/2004 04:20:00 12.8 1.2 14.9 8 12 1.3 14.5 8 0.4 0 0.4 0.4 228 5 227 305 0 0 0 0 2.6 0 3.2 2.5 10/20/2004 04:30:00 13.1 1 15.6 9.5 12.2 1.3 14.9 8.8 0.4 0 0.4 0.4 231 6 238 305 0 0 0 0 2.6 0 3.2 2.5 10/20/2004 04:40:00 13.7 1 16.4 10.7 12.9 1.2 16.8 9.9 0.4 0 0.4 0.4 230 5 221 305 0 0 0 0 2.6 0 3.2 2.5 10/20/2004 04:50:00 12.4 1.2 14.9 8.8 11.5 1.3 14.9 8 0.4 0 0.4 0.4 239 5 239 305 0 0 0 0 2.3 0.1 2.7 2.2 10/20/2004 05:00:00 11.7 1.5 14.5 8.4 10.9 1.7 14.1 6.8 0.4 0 0.4 0.4 238 6 246 305 0 0 0 0 2.3 0.1 2.7 2.2 10/20/2004 05:10:00 11.9 1.5 14.9 8.4 11.1 1.5 14.5 7.6 0.4 0 0.4 0.4 236 6 235 305 0 0 0 0 2.3 0.1 2.7 2.2 10/20/2004 05:20:00 12.6 1.1 15.3 9.5 11.7 1.2 14.5 8 0.4 0 0.4 0.4 230 5 227 305 0 0 0 0 2.5 0 2.9 2.2 10/20/2004 05:30:00 8.6 1.5 13 4.6 7.5 1.5 12.2 3.8 0.4 0 0.4 0.4 253 11 233 305 0 0 0 0 2 0.2 2.7 1.5 10/20/2004 05:40:00 8.8 1 11.1 5.3 7.6 1.2 11.1 4.6 0.4 0 0.4 0.4 257 7 258 305 0 0 0 0 1.4 0 2 1.3 10/20/2004 05:50:00 9.4 1.2 11.8 5.7 8.5 1.4 12.2 5.7 0.4 0 0.4 0.4 253 6 263 305 0 0 0 0 1.2 0.1 1.5 1 10/20/2004 06:00:00 8.6 0.8 10.3 6.1 8.1 1 9.9 5.3 0.4 0 0.4 0.4 244 6 254 305 0 0 0 0 1.1 0.1 1.5 1 10/20/2004 06:10:00 9.5 1.7 12.6 5.3 8.1 1.7 13.3 4.9 0.4 0 0.4 0.4 259 6 262 305 0 0 0 0 1 0.2 1.5 0.6 10/20/2004 06:20:00 8.2 1.2 10.3 4.9 7.3 1.2 10.3 4.2 0.4 0 0.4 0.4 256 7 259 305 0 0 0 0 0.6 0 1 0.6 10/20/2004 06:30:00 8.6 1.1 10.3 5.3 8 1.3 10.7 3.4 0.4 0 0.4 0.4 253 6 261 305 0 0 0 0 0.9 0 1.3 0.6 10/20/2004 06:40:00 8.5 1 10.7 5.7 7.8 1.2 9.9 4.6 0.4 0 0.4 0.4 248 7 244 305 0 0 0 0 1 0 1 0.8 10/20/2004 06:50:00 9.5 1 11.8 6.1 8.8 1.2 11.5 5.3 0.4 0 0.4 0.4 249 7 250 305 0 0 0 0 0.9 0.1 1.3 0.6 10/20/2004 07:00:00 9.2 0.9 11.5 6.1 8.6 1 10.7 5.7 0.4 0 0.4 0.4 242 6 242 305 0 0 0 0 0.7 0 1 0.6 10/20/2004 07:10:00 9.8 1.3 12.6 5.7 9.1 1.4 11.8 5.7 0.4 0 0.4 0.4 241 6 237 305 0 0 0 0 1 0 1.5 1 10/20/2004 07:20:00 10 1.3 12.2 5.7 8.8 1.7 12.6 4.2 0.4 0 0.4 0.4 253 9 237 305 0 0 0 0 1.2 0 1.3 1 10/20/2004 07:30:00 10.1 1 12.6 6.8 8.9 1.3 12.2 5.7 0.4 0 0.4 0.4 253 6 249 305 0 0 0 0 1 0 1.5 1 10/20/2004 07:40:00 10 1.1 12.6 6.8 9 1.3 11.8 5.7 0.4 0 0.4 0.4 253 7 250 305 0 0 0 0 1.1 0 1.5 1 10/20/2004 07:50:00 10.7 1 12.6 8 9.7 1.3 12.2 5.7 0.4 0 0.4 0.4 253 5 248 305 0 0 0 0 1 0 1.5 1 10/20/2004 08:00:00 10.1 1 12.6 6.8 9.4 1.2 12.6 5.7 0.4 0 0.4 0.4 248 6 250 305 0 0 0 0 1 0 1.5 1 10/20/2004 08:10:00 9.6 0.8 11.5 7.2 8.8 1.1 11.5 5.7 0.4 0 0.4 0.4 248 6 252 305 0 0 0 0 1 0 1.5 1 10/20/2004 08:20:00 10 1 11.8 6.1 9.3 1.2 11.1 4.9 0.4 0 0.4 0.4 248 6 251 305 0 0 0 0 1 0 1.5 1 10/20/2004 08:30:00 9.6 1.2 12.2 6.8 8.9 1.3 11.5 5.3 0.4 0 0.4 0.4 247 6 253 305 0 0 0 0 1 0 1.5 1 10/20/2004 08:40:00 9.7 1.2 12.2 6.5 8.9 1.3 12.2 5.7 0.4 0 0.4 0.4 246 8 250 305 0 0 0 0 1.1 0 1.5 1 10/20/2004 08:50:00 10.5 1 13 8 9.6 1.2 12.6 6.1 0.4 0 0.4 0.4 252 5 257 305 0 0 0 0 1 0 1.5 1 10/20/2004 09:00:00 9.7 1.1 12.2 6.5 9 1.3 11.8 5.7 0.4 0 0.4 0.4 247 7 248 305 0 0 0 0 1 0 1.5 1 10/20/2004 09:10:00 9.8 1.1 11.8 6.1 8.9 1.3 11.8 4.6 0.4 0 0.4 0.4 252 6 254 305 0 0 0 0 1 0 1.5 0.8 10/20/2004 09:20:00 9.9 1.1 11.8 6.5 9.5 1.2 11.8 5.7 0.4 0 0.4 0.4 249 6 251 305 0 0 0 0 1 0 1.5 1 10/20/2004 09:30:00 9.6 1.3 12.2 6.1 8.8 1.5 12.6 4.6 0.4 0 0.4 0.4 253 7 254 305 0 0 0 0 1 0 1.5 1 10/20/2004 09:40:00 10.2 1.3 13 6.8 9.1 1.5 13.3 5.3 0.4 0 0.4 0.4 252 7 259 305 0 0 0 0 1 0 1.5 0.8 10/20/2004 09:50:00 10.3 1.5 13.7 6.8 9.4 1.6 13.7 5.7 0.4 0 0.4 0.4 250 7 252 305 0 0 0 0 0.9 0 1.3 0.6 10/20/2004 10:00:00 10.6 1.3 14.1 6.1 9.3 1.5 13.7 5.3 0.4 0 0.4 0.4 255 9 261 305 0 0 0 0 0.8 0 1.3 0.6 10/20/2004 10:10:00 10.6 1.5 14.1 6.8 9.8 1.5 13 6.5 0.4 0 0.4 0.4 248 7 248 305 0 0 0 0 0.7 0.1 1.3 0.6 10/20/2004 10:20:00 10.8 1.3 13.7 6.8 9.7 1.3 13 6.1 0.4 0 0.4 0.4 254 7 258 305 0 0 0 0 0.7 0 1.3 0.6 10/20/2004 10:30:00 10.4 1.2 14.1 6.5 9 1.3 13 5.7 0.4 0 0.4 0.4 255 7 251 305 0 0 0 0 0.7 0.1 1.3 0.6 10/20/2004 10:40:00 11 1.4 14.5 7.2 9.9 1.6 14.5 6.8 0.4 0 0.4 0.4 253 7 253 305 0 0 0 0 0.7 0 1.3 0.6 10/20/2004 10:50:00 12.4 1.3 15.6 8 11.1 1.5 14.5 6.5 0.4 0 0.4 0.4 254 7 251 305 0 0 0 0 0.7 0.1 1.3 0.6 10/20/2004 11:00:00 11.9 1.2 14.5 7.6 10.8 1.5 14.9 6.1 0.4 0 0.4 0.4 253 7 247 305 0 0 0 0 0.5 0 0.8 0.6 10/20/2004 11:10:00 11.4 1.5 14.9 6.5 10.2 1.8 14.1 6.1 0.4 0 0.4 0.4 255 8 259 305 0 0 0 0 0.6 0 1.3 0.6 10/20/2004 11:20:00 13.1 1.1 15.3 9.1 11.8 1.6 15.3 7.2 0.4 0 0.4 0.4 254 7 256 305 0 0 0 0 0.5 0 1 0.6 10/20/2004 11:30:00 11.9 1.4 14.9 7.2 10.8 1.6 14.5 6.8 0.4 0 0.4 0.4 253 7 266 305 0 0 0 0 0.6 0 1 0.3 10/20/2004 11:40:00 11.3 1.3 14.1 7.6 10.2 1.6 13.3 6.1 0.4 0 0.4 0.4 253 8 263 305 0 0 0 0 0.5 0 0.6 0.3 10/20/2004 11:50:00 11.7 1.4 15.3 7.6 10.6 1.8 14.5 5.7 0.4 0 0.4 0.4 253 8 247 305 0 0 0 0 0.5 0 1 0.6 10/20/2004 12:00:00 12.5 1.5 15.3 8 11.2 1.6 14.9 6.8 0.4 0 0.4 0.4 253 8 246 305 0 0 0 0 0.5 0 1 0.6 10/20/2004 12:10:00 11.9 1.3 14.9 8 10.7 1.5 14.1 5.7 0.4 0 0.4 0.4 251 7 256 305 0 0 0 0 0.5 0 1 0.3 10/20/2004 12:20:00 12 1.6 15.6 8 10.9 1.7 15.3 6.8 0.4 0 0.4 0.4 250 7 253 305 0 0 0 0 0.5 0 1 0.3 10/20/2004 12:30:00 12.8 1.3 16.4 8.8 11.8 1.7 15.6 7.2 0.4 0 0.4 0.4 251 5 253 305 0 0 0 0 0.4 0 1 0.3 10/20/2004 12:40:00 12.4 1.5 16.4 8 11.5 1.5 15.6 7.2 0.4 0 0.4 0.4 240 7 245 305 0 0 0 0 0.6 0 1 0.6 10/20/2004 12:50:00 12.7 1.3 15.6 9.1 11.9 1.5 15.3 8 0.4 0 0.4 0.4 239 6 242 305 0 0 0 0 0.6 0 1 0.6 10/20/2004 13:00:00 12.6 1.2 14.9 8.8 12 1.3 14.9 8.4 0.4 0 0.4 0.4 242 6 253 305 0 0 0 0 0.6 0 1 0.6 10/20/2004 13:10:00 12.1 1 14.1 9.1 11.3 1.1 13.7 8.8 0.4 0 0.4 0.4 238 5 234 305 0 0 0 0 0.6 0.1 1.3 0.6 10/20/2004 13:20:00 11.7 1.7 14.9 7.2 10.9 1.9 14.9 5.7 0.4 0 0.4 0.4 248 8 239 305 0 0 0 0 0.5 0 1 0.3 10/20/2004 13:30:00 11.7 1.7 14.9 6.8 10.9 1.7 14.5 6.5 0.4 0 0.4 0.4 245 8 247 305 0 0 0 0 0.5 0 1 0.6 10/20/2004 13:40:00 12.4 1.3 14.9 8.4 11.7 1.4 14.9 7.2 0.4 0 0.4 0.4 245 7 246 305 0 0 0 0 0.6 0 1 0.6 10/20/2004 13:50:00 12.5 1.5 16.4 7.6 11.7 1.7 16.4 6.5 0.4 0 0.4 0.4 247 6 248 305 0 0 0 0 0.5 0 1 0.6 10/20/2004 14:00:00 13.1 1.5 16.1 8 12.1 1.7 15.3 6.8 0.4 0 0.4 0.4 244 8 246 305 0 0 0 0 0.6 0 1 0.6 10/20/2004 14:10:00 12.7 1.2 14.9 8.8 11.9 1.4 14.9 7.6 0.4 0 0.4 0.4 239 6 237 305 0 0 0 0 0.6 0 1 0.3 10/20/2004 14:20:00 12.4 1.5 16.1 8.4 11.6 1.5 15.3 7.6 0.4 0 0.4 0.4 241 6 242 305 0 0 0 0 0.4 0 0.8 0.3 10/20/2004 14:30:00 12.1 1.3 15.3 8.4 11.5 1.6 14.9 7.2 0.4 0 0.4 0.4 246 6 248 305 0 0 0 0 0.4 0 1 0.3 10/20/2004 14:40:00 12.5 1.4 15.6 8.8 11.8 1.5 14.9 8 0.4 0 0.4 0.4 241 8 242 305 0 0 0 0 0.5 0 1 0.6 10/20/2004 14:50:00 12.9 1.6 16.4 7.6 12 1.7 15.6 6.5 0.4 0 0.4 0.4 248 7 232 305 0 0 0 0 0.4 0 0.8 0.3 10/20/2004 15:00:00 12 2.6 17.2 5.7 11.2 2.6 16.1 5.3 0.4 0 0.4 0.4 247 8 244 305 0 0 0 0 0.4 0 0.6 0.3 10/20/2004 15:10:00 13.8 1.3 16.4 8 12.7 1.5 16.1 8 0.4 0 0.4 0.4 250 6 250 305 0 0 0 0 0 0.1 0.6 0.1 10/20/2004 15:20:00 14.6 1.7 18.7 8.8 13.5 2 17.9 6.8 0.4 0 0.4 0.4 253 6 251 305 0 0 0 0 0 0 0.3 -0.1 10/20/2004 15:30:00 14.4 1.5 17.9 9.9 13.3 1.8 18.3 9.1 0.4 0 0.4 0.4 250 6 261 305 0 0 0 0 0 0 0.3 -0.1 10/20/2004 15:40:00 13.2 1.5 16.1 9.1 12.4 1.6 16.4 8.4 0.4 0 0.4 0.4 247 6 241 305 0 0 0 0 -0.3 0 0.1 -0.4 10/20/2004 15:50:00 13.3 1.7 17.6 8.4 12.4 2 17.6 7.6 0.4 0 0.4 0.4 251 7 250 305 0 0 0 0 -0.3 0.1 0.3 -0.6 10/20/2004 16:00:00 13.2 1.3 16.4 8 12.4 1.6 16.1 8 0.4 0 0.4 0.4 247 6 255 305 0 0 0 0 -0.4 0 -0.1 -0.6 10/20/2004 16:10:00 12.2 1.5 15.6 8.4 11.5 1.4 15.6 8.4 0.4 0 0.4 0.4 246 8 248 305 0 0 0 0 -0.5 0 0.1 -0.6 10/20/2004 16:20:00 12.7 2 16.4 7.6 11.8 2.1 15.6 6.5 0.4 0 0.4 0.4 249 7 254 305 0 0 0 0 -0.3 0 0.1 -0.4 10/20/2004 16:30:00 13.5 1.6 16.4 8.8 12.7 1.7 16.1 7.2 0.4 0 0.4 0.4 246 5 249 305 0 0 0 0 -0.3 0.1 0.3 -0.6 10/20/2004 16:40:00 12.8 1.5 16.1 8.4 11.9 1.7 15.6 6.1 0.4 0 0.4 0.4 249 7 255 305 0 0 0 0 -0.5 0.1 0.1 -0.6 10/20/2004 16:50:00 12.7 1.5 16.4 8 11.9 1.6 15.3 6.8 0.4 0 0.4 0.4 248 7 247 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/20/2004 17:00:00 12.2 1.5 15.6 8 10.8 1.5 14.5 6.8 0.4 0 0.4 0.4 252 9 257 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/20/2004 17:10:00 12.6 1.7 16.4 8 11.5 1.8 15.6 6.1 0.4 0 0.4 0.4 249 8 264 305 0 0 0 0 -0.5 0 0.1 -0.6 10/20/2004 17:20:00 13.4 1.6 16.4 8 12.4 1.9 16.4 7.2 0.4 0 0.4 0.4 250 7 256 305 0 0 0 0 -0.5 0.1 0.1 -0.6 10/20/2004 17:30:00 13.3 1.8 17.2 8.8 12.1 2.2 16.8 8 0.4 0 0.4 0.4 250 8 249 305 0 0 0 0 -0.4 0 0.3 -0.4 10/20/2004 17:40:00 12 1.7 15.3 8 10.9 1.7 14.9 6.8 0.4 0 0.4 0.4 251 8 246 305 0 0 0 0 -0.3 0 0.3 -0.4 10/20/2004 17:50:00 13.7 1.5 16.8 8.8 12.6 1.7 16.8 7.2 0.4 0 0.4 0.4 252 6 255 305 0 0 0 0 -0.4 0.1 0.3 -0.6 10/20/2004 18:00:00 13.2 1.7 17.2 9.1 12.3 1.9 17.2 8.4 0.4 0 0.4 0.4 249 6 249 305 0 0 0 0 -0.5 0.1 0.1 -0.6 10/20/2004 18:10:00 13.4 2 17.6 7.6 12.5 2.2 17.2 8 0.4 0 0.4 0.4 248 8 245 305 0 0 0 0 -0.5 0.1 0.1 -0.6 10/20/2004 18:20:00 13.6 2 17.9 7.6 12.2 2.2 17.6 6.5 0.4 0 0.4 0.4 254 7 246 305 0 0 0 0 -0.4 0 0.3 -0.6 10/20/2004 18:30:00 13.9 1.9 17.9 9.1 12.9 2.2 17.6 6.8 0.4 0 0.4 0.4 250 7 255 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/20/2004 18:40:00 13.7 1.5 16.8 8.8 12.2 1.4 15.6 7.6 0.4 0 0.4 0.4 252 8 254 305 0 0 0 0 -0.5 0 -0.1 -0.6 10/20/2004 18:50:00 12.9 1.7 16.1 8 12 2 16.1 7.6 0.4 0 0.4 0.4 250 6 251 305 0 0 0 0 -0.5 0 0.1 -0.6 10/20/2004 19:00:00 14 1.6 17.9 8 12.5 1.8 16.8 7.6 0.4 0 0.4 0.4 256 8 246 305 0 0 0 0 -0.5 0 -0.4 -0.6 10/20/2004 19:10:00 13.7 1.5 16.8 9.1 12.1 1.8 16.8 6.8 0.4 0 0.4 0.4 255 7 250 305 0 0 0 0 -0.5 0 -0.4 -0.6 10/20/2004 19:20:00 13.1 1.8 16.4 7.6 11.7 1.9 15.3 6.5 0.4 0 0.4 0.4 256 8 258 305 0 0 0 0 -0.6 0 -0.1 -0.6 10/20/2004 19:30:00 13.5 1.8 17.9 8 12.3 2.1 17.9 6.8 0.4 0 0.4 0.4 253 7 250 305 0 0 0 0 -0.6 0 -0.1 -0.6 10/20/2004 19:40:00 13.2 1.8 17.9 8.4 11.5 1.9 15.6 7.2 0.4 0 0.4 0.4 258 8 266 305 0 0 0 0 -0.5 0 -0.1 -0.6 10/20/2004 19:50:00 13.3 2.1 18.3 9.1 11.9 2.2 16.8 6.5 0.4 0 0.4 0.4 255 8 256 305 0 0 0 0 -0.5 0 0.1 -0.6 10/20/2004 20:00:00 14 1.5 18.3 8.8 12.2 1.7 16.8 8.4 0.4 0 0.4 0.4 257 6 258 305 0 0 0 0 -0.6 0 -0.4 -0.6 10/20/2004 20:10:00 13.1 1.9 16.8 8 11.7 1.9 16.1 7.2 0.4 0 0.4 0.4 255 6 256 305 0 0 0 0 -0.7 0 -0.1 -0.8 10/20/2004 20:20:00 13.4 1.7 16.8 9.1 12.2 1.7 16.1 7.6 0.4 0 0.4 0.4 252 7 254 305 0 0 0 0 -0.7 0 -0.4 -1.1 10/20/2004 20:30:00 12.9 1.9 16.8 7.2 11.4 1.9 15.3 6.5 0.4 0 0.4 0.4 254 9 266 305 0 0 0 0 -0.7 0 -0.4 -0.8 10/20/2004 20:40:00 12.9 1.6 17.2 8.4 11.2 1.8 14.9 6.8 0.4 0 0.4 0.4 258 7 265 305 0 0 0 0 -0.7 0 -0.4 -1.1 10/20/2004 20:50:00 12.7 2.3 17.6 7.2 10.4 2 14.9 6.1 0.4 0 0.4 0.4 265 7 262 305 0 0 0 0 -0.7 0 -0.4 -0.8 10/20/2004 21:00:00 13.5 2.2 18.3 7.2 11.5 2.1 17.2 5.7 0.4 0 0.4 0.4 259 8 261 305 0 0 0 0 -0.7 0 -0.6 -0.8 10/20/2004 21:10:00 14 1.9 17.6 8.4 12.6 2 17.2 6.5 0.4 0 0.4 0.4 256 7 259 305 0 0 0 0 -0.7 0 -0.1 -0.6 10/20/2004 21:20:00 13.3 1.5 17.2 8.8 11.7 1.7 15.6 8 0.4 0 0.4 0.4 256 8 268 305 0 0 0 0 -0.6 0 -0.1 -0.6 10/20/2004 21:30:00 13.3 1.7 17.2 8.4 11.5 1.8 15.6 6.5 0.4 0 0.4 0.4 257 7 259 305 0 0 0 0 -0.5 0 0.1 -0.6 10/20/2004 21:40:00 13.9 2.1 18.3 8 11.9 2.1 17.6 6.8 0.4 0 0.4 0.4 259 8 250 305 0 0 0 0 -0.6 0 -0.4 -0.6 10/20/2004 21:50:00 13.3 2.1 17.2 7.2 11.6 2.3 16.4 6.5 0.4 0 0.4 0.4 256 8 258 305 0 0 0 0 -0.7 0 -0.4 -0.8 10/20/2004 22:00:00 14.7 1.6 17.9 9.9 12.3 1.9 17.9 6.8 0.4 0 0.4 0.4 261 8 257 305 0 0 0 0 -0.6 0 -0.4 -0.6 10/20/2004 22:10:00 14.1 2 18.3 8 12 2.4 17.2 6.5 0.4 0 0.4 0.4 260 8 266 305 0 0 0 0 -0.6 0 -0.1 -0.6 10/20/2004 22:20:00 14.5 2 18.3 8.8 12.3 1.9 17.2 7.2 0.4 0 0.4 0.4 260 8 267 305 0 0 0 0 -0.6 0 0.1 -0.6 10/20/2004 22:30:00 14.4 2 19.1 9.1 13.1 2 18.3 7.6 0.4 0 0.4 0.4 254 8 261 305 0 0 0 0 -0.6 0 0.1 -0.6 10/20/2004 22:40:00 14.5 2.1 19.9 9.1 12.4 2.1 17.2 6.8 0.4 0 0.4 0.4 260 8 265 305 0 0 0 0 -0.6 0 0.1 -0.6 10/20/2004 22:50:00 14.2 1.7 18.7 9.9 12.8 2 18.3 8 0.4 0 0.4 0.4 255 8 254 305 0 0 0 0 -0.7 0 -0.4 -0.8 10/20/2004 23:00:00 14.7 1.9 18.7 8.8 13 2 17.6 7.6 0.4 0 0.4 0.4 258 7 261 305 0 0 0 0 -0.7 0 -0.4 -0.8 10/20/2004 23:10:00 13.8 2.3 19.5 7.2 11.6 2.2 17.2 5.7 0.4 0 0.4 0.4 264 9 264 305 0 0 0 0 -0.8 0 -0.4 -1.1 10/20/2004 23:20:00 13.9 2 17.6 8.4 11.4 1.8 15.6 6.5 0.4 0 0.4 0.4 266 8 265 305 0 0 0 0 -0.8 0 -0.1 -1.1 10/20/2004 23:30:00 15 1.6 18.7 9.5 12.6 1.8 17.2 6.8 0.4 0 0.4 0.4 263 7 259 305 0 0 0 0 -0.8 0 -0.4 -1.1 10/20/2004 23:40:00 14.2 2.3 19.5 6.5 12.1 2.2 17.2 7.2 0.4 0 0.4 0.4 262 9 263 305 0 0 0 0 -0.8 0 -0.4 -1.1 10/20/2004 23:50:00 14.1 1.7 17.9 8.8 11.9 2 16.4 6.8 0.4 0 0.4 0.4 262 8 273 305 0 0 0 0 -0.7 0 -0.4 -0.8 10/21/2004 00:00:00 14.9 1.9 18.7 9.9 12.4 2 18.3 6.5 0.4 0 0.4 0.4 262 8 268 305 0 0 0 0 -0.8 0 -0.4 -1.1 10/21/2004 00:10:00 14.3 2.3 19.1 8.4 12.4 2.4 17.9 6.5 0.4 0 0.4 0.4 260 8 258 305 0 0 0 0 -0.7 0 -0.1 -0.8 10/21/2004 00:20:00 14.8 1.9 19.9 9.9 12.4 2 17.2 8.4 0.4 0 0.4 0.4 262 8 264 305 0 0 0 0 -0.7 0 -0.4 -0.8 10/21/2004 00:30:00 14 2.3 18.7 8 11.5 2.1 16.1 6.5 0.4 0 0.4 0.4 266 7 270 305 0 0 0 0 -0.7 0 -0.4 -1.1 10/21/2004 00:40:00 14.6 2.4 19.9 9.1 12.8 2.5 18.7 6.8 0.4 0 0.4 0.4 258 8 264 305 0 0 0 0 -0.6 0 -0.4 -0.8 10/21/2004 00:50:00 14.6 2.2 19.1 8 12.1 2 17.6 6.5 0.4 0 0.4 0.4 264 8 262 305 0 0 0 0 -0.6 0 -0.1 -0.6 10/21/2004 01:00:00 14 2.1 18.3 9.1 11.5 2.3 18.3 6.5 0.4 0 0.4 0.4 263 7 252 305 0 0 0 0 -0.6 0 -0.1 -0.6 10/21/2004 01:10:00 14.7 2.2 19.1 8.8 12.6 2.3 19.5 6.5 0.4 0 0.4 0.4 263 9 250 305 0 0 0 0 -0.5 0 -0.1 -0.6 10/21/2004 01:20:00 13.6 1.8 17.2 7.6 11.3 1.7 16.1 6.8 0.4 0 0.4 0.4 265 8 260 305 0 0 0 0 -0.6 0 -0.1 -0.6 10/21/2004 01:30:00 15.3 2.1 19.5 9.1 12.8 2 16.8 6.8 0.4 0 0.4 0.4 260 7 260 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 01:40:00 14.5 2.2 20.2 8.4 12.4 2.5 19.1 6.1 0.4 0 0.4 0.4 258 8 260 305 0 0 0 0 -0.5 0.1 0.1 -0.6 10/21/2004 01:50:00 13.9 1.7 17.6 9.1 12.1 1.9 17.6 6.8 0.4 0 0.4 0.4 258 10 249 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 02:00:00 15 2.3 19.9 8 12.9 2.3 18.7 6.5 0.4 0 0.4 0.4 258 7 252 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 02:10:00 15.4 1.9 19.9 9.5 13.5 2.4 19.5 6.8 0.4 0 0.4 0.4 256 7 244 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 02:20:00 14.8 1.8 19.9 9.9 12.9 2.2 17.9 7.6 0.4 0 0.4 0.4 256 7 255 305 0 0 0 0 -0.3 0 0.1 -0.4 10/21/2004 02:30:00 15.5 2 19.9 9.1 13.9 2.5 19.5 6.8 0.4 0 0.4 0.4 256 6 256 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 02:40:00 15.5 2.1 19.9 9.1 13.5 2.1 18.7 8 0.4 0 0.4 0.4 257 6 258 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 02:50:00 15.9 2 20.2 10.7 14.6 2.2 20.6 7.6 0.4 0 0.4 0.4 254 6 255 305 0 0 0 0 -0.4 0 0.1 -0.6 10/21/2004 03:00:00 14.6 1.7 18.7 8.4 13 2.1 18.3 7.6 0.4 0 0.4 0.4 255 7 253 305 0 0 0 0 -0.4 0 0.1 -0.4 10/21/2004 03:10:00 15.5 1.6 19.1 9.9 13.3 1.7 17.6 8 0.4 0 0.4 0.4 258 6 263 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 03:20:00 15.9 1.8 19.9 9.1 14.4 2 19.5 8.8 0.4 0 0.4 0.4 253 7 249 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 03:30:00 14.2 2.4 18.7 8.4 12.3 2.7 18.7 5.7 0.4 0 0.4 0.4 257 8 261 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 03:40:00 14.7 2 18.7 9.5 12.7 2 17.6 7.2 0.4 0 0.4 0.4 257 8 256 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 03:50:00 13.4 2 17.6 7.6 12.1 2.2 16.8 6.1 0.4 0 0.4 0.4 253 8 245 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 04:00:00 15.3 1.6 18.3 11.1 13.8 1.9 18.7 9.1 0.4 0 0.4 0.4 254 6 252 305 0 0 0 0 -0.4 0 0.1 -0.6 10/21/2004 04:10:00 15.7 1.6 19.9 10.7 13.7 1.7 18.7 9.1 0.4 0 0.4 0.4 255 7 252 305 0 0 0 0 -0.4 0 0.1 -0.4 10/21/2004 04:20:00 15.7 1.9 19.5 9.5 14 2.2 18.3 7.2 0.4 0 0.4 0.4 255 6 259 305 0 0 0 0 -0.4 0 0.1 -0.6 10/21/2004 04:30:00 15.4 1.7 19.1 11.1 12.9 1.7 17.9 8.8 0.4 0 0.4 0.4 260 8 268 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 04:40:00 15.2 1.7 18.7 9.5 12.4 1.7 16.8 7.2 0.4 0 0.4 0.4 263 7 263 305 0 0 0 0 -0.3 0 0.1 -0.4 10/21/2004 04:50:00 14.6 1.8 17.6 9.5 12 1.7 16.1 7.2 0.4 0 0.4 0.4 263 7 273 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 05:00:00 14.9 1.8 19.1 9.5 12.4 1.8 18.3 8 0.4 0 0.4 0.4 269 8 269 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 05:10:00 14.5 2.5 19.9 8 11.9 2.4 18.3 6.1 0.4 0 0.4 0.4 266 8 265 305 0 0 0 0 -0.3 0.1 0.1 -0.4 10/21/2004 05:20:00 13.3 1.8 17.6 8.4 11.1 1.7 16.1 6.8 0.4 0 0.4 0.4 270 8 262 305 0 0 0 0 -0.3 0.1 0.3 -0.4 10/21/2004 05:30:00 14.7 1.9 19.1 9.5 12 1.9 17.6 6.5 0.4 0 0.4 0.4 270 8 268 305 0 0 0 0 -0.4 0.2 0.3 -0.6 10/21/2004 05:40:00 13.8 2.8 19.5 8 11.4 2.6 17.2 6.1 0.4 0 0.4 0.4 270 10 270 305 0 0 0 0 -0.3 0.1 0.1 -0.4 10/21/2004 05:50:00 14.1 2.1 18.7 8.4 11.4 1.7 16.1 7.6 0.4 0 0.4 0.4 269 8 266 305 0 0 0 0 -0.4 0.1 0.3 -0.6 10/21/2004 06:00:00 13.9 2.1 18.3 7.6 11.4 1.9 16.4 6.1 0.4 0 0.4 0.4 268 9 266 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 06:10:00 14.1 1.9 17.6 8.8 12.1 2 16.8 7.6 0.4 0 0.4 0.4 275 8 273 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 06:20:00 14 2 18.7 8 11.7 2 17.6 6.8 0.4 0 0.4 0.4 272 8 276 305 0 0 0 0 -0.5 0.1 0.1 -0.6 10/21/2004 06:30:00 13.6 1.7 19.1 9.5 11.5 2 16.4 6.8 0.4 0 0.4 0.4 274 9 274 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 06:40:00 14.8 1.7 18.7 9.1 12.6 1.9 17.6 7.2 0.4 0 0.4 0.4 274 7 288 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 06:50:00 13.1 1.9 17.9 8 11 1.9 16.1 6.8 0.4 0 0.4 0.4 273 9 265 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 07:00:00 13.5 1.8 17.2 8.4 11.3 2 16.4 6.5 0.4 0 0.4 0.4 271 10 276 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 07:10:00 14.1 2.3 17.9 8.4 11.3 2.1 15.6 6.5 0.4 0 0.4 0.4 269 8 275 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 07:20:00 14.3 2.2 19.9 6.8 12.1 2.1 17.6 6.1 0.4 0 0.4 0.4 275 8 275 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 07:30:00 14.2 2.5 20.6 9.1 11.8 2.4 17.9 6.1 0.4 0 0.4 0.4 272 7 264 305 0 0 0 0 -0.4 0 0.1 -0.6 10/21/2004 07:40:00 14 2 17.6 6.5 11.3 1.8 15.6 4.9 0.4 0 0.4 0.4 269 8 260 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 07:50:00 14.2 1.6 18.3 9.9 11.4 1.5 15.6 6.8 0.4 0 0.4 0.4 266 8 265 305 0 0 0 0 -0.5 0 0.1 -0.6 10/21/2004 08:00:00 14.7 1.9 19.9 10.3 11.9 1.8 18.7 6.8 0.4 0 0.4 0.4 265 7 258 305 0 0 0 0 -0.5 0.1 0.1 -0.6 10/21/2004 08:10:00 15.5 1.8 20.2 10.7 12.5 1.7 16.4 8 0.4 0 0.4 0.4 267 8 261 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 08:20:00 15.6 1.8 19.9 9.5 12.6 1.7 17.6 8 0.4 0 0.4 0.4 271 7 267 305 0 0 0 0 -0.5 0.1 0.1 -0.6 10/21/2004 08:30:00 15 2.1 19.1 9.5 12.5 2.1 17.9 8 0.4 0 0.4 0.4 271 8 280 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/21/2004 08:40:00 15.7 2.3 20.6 9.1 13.2 2.3 19.1 7.6 0.4 0 0.4 0.4 274 8 270 305 0 0 0 0 -0.4 0 0.1 -0.6 10/21/2004 08:50:00 14.9 2.2 19.9 9.5 12.2 1.8 17.2 6.8 0.4 0 0.4 0.4 267 8 270 305 0 0 0 0 -0.3 0 0.3 -0.4 10/21/2004 09:00:00 16.1 2.1 21.8 9.5 13.4 2 18.7 8.4 0.4 0 0.4 0.4 261 8 265 305 0 0 0 0 -0.3 0 0.3 -0.4 10/21/2004 09:10:00 15.9 1.7 19.5 9.1 13 1.6 17.6 8.4 0.4 0 0.4 0.4 266 8 263 305 0 0 0 0 -0.3 0.1 0.3 -0.4 10/21/2004 09:20:00 14.9 2 19.1 9.1 12.3 1.9 16.8 6.8 0.4 0 0.4 0.4 269 9 269 305 0 0 0 0 -0.2 0 0.3 -0.4 10/21/2004 09:30:00 15.3 2.4 19.9 8 12.8 2.3 17.9 7.2 0.4 0 0.4 0.4 273 6 273 305 0 0 0 0 -0.3 0.1 0.3 -0.4 10/21/2004 09:40:00 14.1 2 18.3 9.1 11.4 1.6 15.6 6.8 0.4 0 0.4 0.4 270 7 275 305 0 0 0 0 -0.2 0 0.3 -0.4 10/21/2004 09:50:00 14.1 1.8 17.9 8.8 11.3 1.7 16.1 6.5 0.4 0 0.4 0.4 266 7 275 305 0 0 0 0 -0.4 0.1 0.3 -0.6 10/21/2004 10:00:00 13.9 2 18.7 8 11.9 2.1 17.2 6.1 0.4 0 0.4 0.4 259 7 256 305 0 0 0 0 -0.3 0 0.1 -0.4 10/21/2004 10:10:00 14.4 1.8 17.9 8 12.3 1.9 16.8 6.5 0.4 0 0.4 0.4 259 8 269 305 0 0 0 0 -0.3 0 0.3 -0.4 10/21/2004 10:20:00 14.7 1.7 20.2 9.1 12.8 2 19.9 7.2 0.4 0 0.4 0.4 257 7 251 305 0 0 0 0 -0.3 0 0.1 -0.4 10/21/2004 10:30:00 14.1 1.9 19.5 7.6 12.1 2 17.6 7.2 0.4 0 0.4 0.4 259 8 251 305 0 0 0 0 -0.3 0 0.1 -0.4 10/21/2004 10:40:00 13.7 1.6 17.6 8.8 11.1 1.7 16.1 5.3 0.4 0 0.4 0.4 263 7 261 305 0 0 0 0 -0.3 0 0.3 -0.4 10/21/2004 10:50:00 13.6 1.6 17.9 9.5 11.5 1.6 15.6 7.2 0.4 0 0.4 0.4 260 7 259 305 0 0 0 0 -0.2 0 0.3 -0.4 10/21/2004 11:00:00 14.1 1.5 17.6 10.3 12.8 2 17.6 8.4 0.4 0 0.4 0.4 253 7 251 305 0 0 0 0 -0.2 0 0.1 -0.4 10/21/2004 11:10:00 12.9 2 17.2 7.2 10.7 1.8 16.4 6.5 0.4 0 0.4 0.4 264 8 265 305 0 0 0 0 -0.3 0 0.3 -0.4 10/21/2004 11:20:00 12.1 1.5 15.6 7.6 10.1 1.5 14.5 6.5 0.4 0 0.4 0.4 261 7 258 305 0 0 0 0 -0.3 0 0.3 -0.4 10/21/2004 11:30:00 11.9 1.5 15.6 7.6 9.9 1.7 14.1 4.6 0.4 0 0.4 0.4 261 8 263 305 0 0 0 0 -0.2 0 0.3 -0.4 10/21/2004 11:40:00 12 1.8 16.1 7.2 11 2.4 16.1 5.3 0.4 0 0.4 0.4 253 8 249 305 0 0 0 0 -0.1 0 0.1 -0.4 10/21/2004 11:50:00 12.4 1.7 15.3 6.8 10.8 1.7 15.3 5.7 0.4 0 0.4 0.4 257 7 249 305 0 0 0 0 -0.1 0 0.3 -0.4 10/21/2004 12:00:00 12 1.3 14.9 7.2 10.2 1.5 14.1 6.5 0.4 0 0.4 0.4 258 8 254 305 0 0 0 0 -0.1 0 0.1 -0.4 10/21/2004 12:10:00 11.5 1.3 14.1 7.2 10.3 1.3 13.3 6.8 0.4 0 0.4 0.4 252 9 264 305 0 0 0 0 0 0.1 0.6 0.1 10/21/2004 12:20:00 11 1.6 14.9 7.6 9 1.5 13 6.1 0.4 0 0.4 0.4 263 6 266 305 0 0 0 0 0.1 0 0.6 -0.1 10/21/2004 12:30:00 10.6 1.5 14.1 7.2 9.1 1.6 13 4.9 0.4 0 0.4 0.4 259 9 258 305 0 0 0 0 0 0 0.6 0.1 10/21/2004 12:40:00 10.1 1.3 13.3 6.5 8.8 1.4 12.2 4.9 0.4 0 0.4 0.4 257 10 258 305 0 0 0 0 0.1 0 0.6 0.1 10/21/2004 12:50:00 10.9 1.6 14.5 6.1 9.6 1.5 14.1 5.3 0.4 0 0.4 0.4 254 8 261 305 0 0 0 0 0.2 0 0.6 0.1 10/21/2004 13:00:00 9.8 1.2 13.7 6.5 8.9 1.4 12.6 6.1 0.4 0 0.4 0.4 254 8 259 305 0 0 0 0 0.3 0 0.8 0.1 10/21/2004 13:10:00 9.8 1.2 12.6 6.1 8.6 1.3 11.8 5.3 0.4 0 0.4 0.4 257 7 251 305 0 0 0 0 0.4 0 0.8 0.3 10/21/2004 13:20:00 9.5 1.5 13 5.3 8.4 1.7 13 4.9 0.4 0 0.4 0.4 258 8 250 305 0 0 0 0 0.5 0 1 0.3 10/21/2004 13:30:00 9.9 1.7 14.1 5.3 9.1 1.9 13.7 4.9 0.4 0 0.4 0.4 252 8 251 305 0 0 0 0 0.5 0 1 0.3 10/21/2004 13:40:00 8.6 1 11.1 5.3 7.5 1.1 10.7 4.6 0.4 0 0.4 0.4 257 8 258 305 0 0 0 0 0.4 0 0.8 0.3 10/21/2004 13:50:00 9.3 1 11.5 6.5 8.4 1.1 11.5 6.1 0.4 0 0.4 0.4 251 7 248 305 0 0 0 0 0.5 0 1 0.3 10/21/2004 14:00:00 9.2 1.3 12.2 5.3 8.4 1.6 11.5 4.2 0.4 0 0.4 0.4 250 9 251 305 0 0 0 0 0.5 0 1 0.3 10/21/2004 14:10:00 8.1 1 9.9 4.6 7.3 1.1 10.3 3 0.4 0 0.4 0.4 248 13 266 305 0 0 0 0 0.6 0 1 0.6 10/21/2004 14:20:00 8.8 0.9 11.5 6.8 8.3 0.9 10.7 6.1 0.4 0 0.4 0.4 236 7 234 305 0 0 0 0 0.6 0.1 1.3 0.6 10/21/2004 14:30:00 8.7 1 10.7 5.3 8.2 1.1 10.7 5.3 0.4 0 0.4 0.4 236 7 238 305 0 0 0 0 0.6 0 1 0.3 10/21/2004 14:40:00 8.9 1 11.5 6.1 8.3 1.1 11.1 5.3 0.4 0 0.4 0.4 240 6 245 305 0 0 0 0 0.7 0.1 1.3 0.6 10/21/2004 14:50:00 7.9 0.8 9.5 5.3 7.4 0.8 9.1 4.6 0.4 0 0.4 0.4 238 6 245 305 0 0 0 0 1 0 1.5 0.8 10/21/2004 15:00:00 10.1 1.4 12.2 5.7 9.5 1.6 12.2 5.7 0.4 0 0.4 0.4 233 8 232 305 0 0 0 0 1 0 1.5 1 10/21/2004 15:10:00 10.8 0.9 12.6 7.6 10.3 1.1 12.2 6.8 0.4 0 0.4 0.4 229 5 232 305 0 0 0 0 1.1 0.1 1.5 1 10/21/2004 15:20:00 9.5 1.1 11.8 6.8 8.8 1.1 11.8 5.7 0.4 0 0.4 0.4 229 7 227 305 0 0 0 0 1.1 0 1.5 1 10/21/2004 15:30:00 9.5 1.1 11.8 6.5 8.9 1.2 11.5 6.5 0.4 0 0.4 0.4 235 7 247 305 0 0 0 0 1 0 1.5 0.8 10/21/2004 15:40:00 10 1 12.2 7.2 9.4 1.1 11.8 6.5 0.4 0 0.4 0.4 233 6 241 305 0 0 0 0 1 0 1.5 1 10/21/2004 15:50:00 8.1 1.1 10.7 4.9 7.6 1.1 9.9 5.3 0.4 0 0.4 0.4 237 7 239 305 0 0 0 0 1 0 1.5 1 10/21/2004 16:00:00 8.4 0.9 11.1 6.1 7.9 0.9 10.3 5.7 0.4 0 0.4 0.4 232 6 226 305 0 0 0 0 1.1 0 1.5 1 10/21/2004 16:10:00 8.6 1 11.1 5.7 8.1 1.1 10.7 5.3 0.4 0 0.4 0.4 227 7 234 305 0 0 0 0 1.2 0.1 1.7 1 10/21/2004 16:20:00 9.1 0.8 10.7 5.7 8.6 0.9 10.7 6.1 0.4 0 0.4 0.4 223 5 227 305 0 0 0 0 1.3 0 1.7 1.3 10/21/2004 16:30:00 8.9 0.7 10.3 6.8 8.5 0.9 10.3 6.5 0.4 0 0.4 0.4 223 5 231 305 0 0 0 0 1.3 0 1.7 1.3 10/21/2004 16:40:00 8.4 0.8 9.9 6.1 8.1 0.9 9.9 5.7 0.4 0 0.4 0.4 221 5 224 305 0 0 0 0 1.3 0 1.5 1.3 10/21/2004 16:50:00 8 0.7 9.1 6.1 7.8 0.7 9.5 5.3 0.4 0 0.4 0.4 218 5 220 305 0 0 0 0 1.3 0 1.7 1.3 10/21/2004 17:00:00 7 0.9 8.8 4.6 6.7 1 8.4 4.6 0.4 0 0.4 0.4 215 6 213 305 0 0 0 0 1.3 0 2 1.3 10/21/2004 17:10:00 7 0.6 8.4 4.9 6.8 0.7 8.8 4.9 0.4 0 0.4 0.4 212 6 213 305 0 0 0 0 1.3 0 1.7 1.3 10/21/2004 17:20:00 6.7 0.6 8 4.9 6.7 0.7 8 4.9 0.4 0 0.4 0.4 206 5 206 305 0 0 0 0 1.4 0 2 1.3 10/21/2004 17:30:00 6.1 0.8 7.6 2.6 6.1 0.7 7.6 4.6 0.4 0 0.4 0.4 201 8 198 305 0 0 0 0 1.4 0 2 1.3 10/21/2004 17:40:00 4.6 0.8 6.5 2.3 5.2 0.6 6.5 3.8 0.4 0 0.4 0.4 181 5 188 305 0 0 0 0 1.2 0.1 1.7 1 10/21/2004 17:50:00 3.3 0.8 5.7 1.9 4.3 0.6 6.1 3 0.4 0 0.4 0.4 171 8 185 305 0 0 0 0 1.2 0.1 1.5 1 10/21/2004 18:00:00 3.4 0.6 4.9 1.9 3.7 0.4 4.9 2.6 0.4 0 0.4 0.4 156 6 156 305 0 0 0 0 0.9 0 1.5 0.8 10/21/2004 18:10:00 3.7 0.5 4.9 1.9 4 0.4 4.9 2.6 0.4 0 0.4 0.4 153 5 154 305 0 0 0 0 0.8 0 1.3 0.6 10/21/2004 18:20:00 3.6 0.5 4.9 2.3 3.9 0.5 4.9 2.6 0.4 0 0.4 0.4 146 6 156 305 0 0 0 0 0.8 0 1.3 0.6 10/21/2004 18:30:00 3.3 0.6 4.9 1.9 3.5 0.5 4.9 1.9 0.4 0 0.4 0.4 145 9 152 305 0 0 0 0 0.9 0 1.3 0.8 10/21/2004 18:40:00 3.3 0.6 4.9 1.9 3.6 0.6 4.9 2.3 0.4 0 0.4 0.4 140 10 151 305 0 0 0 0 1 0 1.3 0.8 10/21/2004 18:50:00 3.7 0.6 5.3 2.3 4 0.5 5.7 2.6 0.4 0 0.4 0.4 144 8 150 305 0 0 0 0 1 0 1.5 0.8 10/21/2004 19:00:00 4 0.6 5.3 2.3 4.3 0.6 5.7 3 0.4 0 0.4 0.4 140 8 139 305 0 0 0 0 0.9 0 1.3 0.8 10/21/2004 19:10:00 4.6 0.5 6.1 3 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 134 5 137 305 0 0 0 0 0.9 0 1.3 0.8 10/21/2004 19:20:00 4.2 0.7 5.7 1.9 4.3 0.6 5.7 2.6 0.4 0 0.4 0.4 134 7 121 305 0 0 0 0 1 0 1.5 1 10/21/2004 19:30:00 2.7 1 4.6 0.4 2.8 0.8 4.9 0.7 0.4 0 0.4 0.4 115 19 127 305 0 0 0 0 1 0 1.5 1 10/21/2004 19:40:00 2.5 0.8 4.6 0.4 2.7 0.8 5.3 1.1 0.4 0 0.4 0.4 110 20 93 305 0 0 0 0 1 0 1.5 0.8 10/21/2004 19:50:00 2.7 1.3 6.1 0.4 2.9 1.1 5.7 0.4 0.4 0 0.4 0.4 100 27 116 305 0 0 0 0 1 0 1.5 0.8 10/21/2004 20:00:00 3.6 1.2 7.2 0.4 3.8 1.1 7.6 1.5 0.4 0 0.4 0.4 96 22 89 305 0 0 0 0 1.1 0 1.5 1 10/21/2004 20:10:00 4.2 1.5 7.6 0.4 4.2 1.3 7.6 1.1 0.4 0 0.4 0.4 99 22 103 305 0 0 0 0 1.3 0.1 1.7 1 10/21/2004 20:20:00 4.9 1.6 8.4 0.4 5 1.5 9.5 1.5 0.4 0 0.4 0.4 93 19 103 305 0 0 0 0 1.4 0 1.7 1.3 10/21/2004 20:30:00 6.2 1.5 9.9 2.6 6.1 1.5 9.9 2.3 0.4 0 0.4 0.4 84 17 60 305 0 0 0 0 1.4 0 1.7 1.3 10/21/2004 20:40:00 6.8 1.5 11.1 3 6.9 1.5 11.1 2.3 0.4 0 0.4 0.4 82 20 63 305 0 0 0 0 1.6 0 2 1.5 10/21/2004 20:50:00 6.9 1.5 12.2 3 6.8 1.5 11.1 3.4 0.4 0 0.4 0.4 77 19 59 305 0 0 0 0 1.5 0 2 1.3 10/21/2004 21:00:00 6.4 1.6 11.5 2.6 6.3 1.7 11.8 1.1 0.4 0 0.4 0.4 76 22 73 305 0 0 0 0 1.5 0 2 1.5 10/21/2004 21:10:00 8.2 1.9 11.8 3.4 8.2 1.8 12.2 3.8 0.4 0 0.4 0.4 74 14 67 305 0 0 0 0 1.5 0 2.2 1.3 10/21/2004 21:20:00 9.4 0.6 10.7 7.6 9.1 0.7 10.7 6.8 0.4 0 0.4 0.4 74 5 70 305 0 0 0 0 1.1 0 1.5 1 10/21/2004 21:30:00 9.7 0.9 11.5 7.6 9.5 0.9 11.1 7.2 0.4 0 0.4 0.4 72 5 68 305 0 0 0 0 1 0 1.5 0.8 10/21/2004 21:40:00 9.8 0.8 11.8 7.2 9.6 0.8 11.8 7.6 0.4 0 0.4 0.4 70 4 71 305 0 0 0 0 1.1 0 1.5 1 10/21/2004 21:50:00 10.2 0.7 12.2 8.8 10 0.7 11.5 8.4 0.4 0 0.4 0.4 70 4 67 305 0 0 0 0 1.3 0 2 1 10/21/2004 22:00:00 10.2 0.8 11.8 7.2 9.8 0.8 11.5 7.2 0.4 0 0.4 0.4 79 6 87 305 0 0 0 0 1.6 0 2.2 1.5 10/21/2004 22:10:00 10.2 0.7 12.2 8.4 10 0.7 11.8 8 0.4 0 0.4 0.4 83 6 88 305 0 0 0 0 1.6 0 2.2 1.5 10/21/2004 22:20:00 9.5 1 13 5.3 9.2 1 11.8 5.7 0.4 0 0.4 0.4 83 7 82 305 0 0 0 0 1.7 0.1 2.2 1.5 10/21/2004 22:30:00 9.9 1 11.8 7.2 9.6 1 11.8 7.2 0.4 0 0.4 0.4 80 6 74 305 0 0 0 0 2 0 2.7 2 10/21/2004 22:40:00 9.6 1 11.5 6.5 9.3 1 11.5 6.5 0.4 0 0.4 0.4 82 6 81 305 0 0 0 0 2.2 0 2.7 2 10/21/2004 22:50:00 9.9 0.8 12.6 7.6 9.5 0.8 11.5 7.6 0.4 0 0.4 0.4 81 6 96 305 0 0 0 0 2.3 0.1 2.7 2.2 10/21/2004 23:00:00 9.9 0.8 12.2 7.2 9.5 0.8 12.2 7.2 0.4 0 0.4 0.4 82 7 82 305 0 0 0 0 2.3 0.1 2.7 2.2 10/21/2004 23:10:00 9.7 0.9 12.2 6.8 9.4 0.9 11.8 6.8 0.4 0 0.4 0.4 81 6 81 305 0 0 0 0 2.3 0.1 2.9 2.2 10/21/2004 23:20:00 9.7 0.9 12.2 6.5 9.4 1 11.5 6.5 0.4 0 0.4 0.4 81 6 81 305 0 0 0 0 2.3 0.1 2.9 2.2 10/21/2004 23:30:00 9.6 0.8 11.8 7.2 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 80 6 78 305 0 0 0 0 2.4 0 2.9 2.2 10/21/2004 23:40:00 10 0.7 12.2 6.8 9.6 0.7 11.5 7.6 0.4 0 0.4 0.4 78 5 79 305 0 0 0 0 2.5 0 3.2 2.2 10/21/2004 23:50:00 9.6 0.7 11.1 7.6 9.2 0.7 11.1 7.6 0.4 0 0.4 0.4 80 5 86 305 0 0 0 0 2.6 0 3.2 2.5 10/22/2004 00:00:00 9.4 0.9 11.1 6.8 9 0.9 11.1 6.5 0.4 0 0.4 0.4 79 6 70 305 0 0 0 0 2.6 0 3.2 2.5 10/22/2004 00:10:00 8.9 0.8 10.7 6.5 8.6 0.8 10.3 6.5 0.4 0 0.4 0.4 75 6 70 305 0 0 0 0 2.7 0 3.4 2.5 10/22/2004 00:20:00 9.1 0.8 11.1 6.8 8.7 0.8 10.7 6.5 0.4 0 0.4 0.4 74 5 67 305 0 0 0 0 2.8 0.1 3.2 2.7 10/22/2004 00:30:00 9 0.7 10.7 7.2 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 72 5 77 305 0 0 0 0 2.9 0 3.4 2.7 10/22/2004 00:40:00 9.3 0.6 11.1 8 9 0.6 10.7 7.6 0.4 0 0.4 0.4 69 4 67 305 0 0 0 0 3 0 3.4 2.9 10/22/2004 00:50:00 9.9 0.6 11.5 8.4 9.5 0.6 11.1 7.6 0.4 0 0.4 0.4 68 3 70 305 0 0 0 0 3.1 0 3.7 2.9 10/22/2004 01:00:00 9.4 0.8 11.5 6.8 9 0.8 10.7 6.8 0.4 0 0.4 0.4 69 5 71 305 0 0 1 0 3.2 0 3.7 3.2 10/22/2004 01:10:00 8.9 0.7 11.5 6.8 8.5 0.8 11.5 6.1 0.4 0 0.4 0.4 75 5 77 305 0 0 0 0 3.1 0 3.4 2.9 10/22/2004 01:20:00 8.9 0.6 10.3 7.2 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 73 4 73 305 0 0 0 0 3.1 0 3.4 2.9 10/22/2004 01:30:00 9.2 0.7 10.7 7.2 8.8 0.8 10.7 6.8 0.4 0 0.4 0.4 69 4 66 305 0 0 0 0 3.2 0 3.7 3.2 10/22/2004 01:40:00 9 0.6 10.7 7.2 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 69 4 64 305 0 0 0 0 3.2 0 3.7 3.2 10/22/2004 01:50:00 9.4 0.4 10.3 8.4 9 0.4 9.9 7.6 0.4 0 0.4 0.4 68 3 66 305 0 0 0 0 3.2 0 3.7 3.2 10/22/2004 02:00:00 9.1 0.5 10.3 7.6 8.7 0.6 9.9 7.2 0.4 0 0.4 0.4 70 3 67 305 0 0 0 0 3.2 0 3.7 3.2 10/22/2004 02:10:00 8.9 0.6 10.3 6.8 8.4 0.6 9.5 6.5 0.4 0 0.4 0.4 67 3 64 305 0 0 0 0 3.3 0 3.7 3.2 10/22/2004 02:20:00 9.2 0.5 10.3 7.6 8.8 0.6 9.9 6.8 0.4 0 0.4 0.4 65 3 66 305 0 0 0 0 3.4 0 3.7 3.2 10/22/2004 02:30:00 8.5 0.7 9.9 6.8 8.1 0.7 9.5 6.1 0.4 0 0.4 0.4 65 3 67 305 0 0 0 0 3.4 0.1 3.7 3.2 10/22/2004 02:40:00 8.4 0.8 9.9 6.5 8 0.7 9.5 6.1 0.4 0 0.4 0.4 63 4 66 305 0 0 0 0 3.5 0 3.7 3.4 10/22/2004 02:50:00 9.7 0.9 11.5 7.2 9.3 1 11.5 6.5 0.4 0 0.4 0.4 54 5 45 305 0 0 0 0 3.6 0 3.9 3.4 10/22/2004 03:00:00 10.4 0.7 11.8 8.4 10.2 0.8 11.8 8 0.4 0 0.4 0.4 43 5 38 305 0 0 0 0 3.4 0 3.7 3.2 10/22/2004 03:10:00 11.6 0.7 13 9.5 11.4 0.8 13 9.1 0.4 0 0.4 0.4 36 3 36 305 0 0 0 0 3.1 0 3.4 2.9 10/22/2004 03:20:00 12 0.8 13.7 9.5 11.8 1 13.7 8.8 0.4 0 0.4 0.4 37 3 35 305 0 0 1 0 3.1 0 3.2 2.9 10/22/2004 03:30:00 12.2 0.8 14.5 9.9 11.9 0.9 13.7 9.9 0.4 0 0.4 0.4 38 4 41 305 1 0 1 0 3.1 0 3.4 2.9 10/22/2004 03:40:00 12.8 0.7 14.5 10.3 12.5 0.8 14.1 10.3 0.4 0 0.4 0.4 39 3 40 305 1 0 1 0 3 0 3.2 2.9 10/22/2004 03:50:00 12.6 0.7 14.1 9.9 12.4 0.8 14.1 9.9 0.4 0 0.4 0.4 39 3 39 305 1 0 1 0 3 0 3.2 2.9 10/22/2004 04:00:00 12.7 0.8 14.5 10.3 12.5 0.8 14.5 10.7 0.4 0 0.4 0.4 39 3 38 305 1 0 1 0 3 0 3.4 2.9 10/22/2004 04:10:00 12.6 0.8 14.5 9.5 12.3 1 14.5 9.1 0.4 0 0.4 0.4 37 3 33 305 1 0 1 0 2.9 0 3.2 2.9 10/22/2004 04:20:00 13.5 0.7 14.9 11.5 13.4 0.7 14.9 11.5 0.4 0 0.4 0.4 35 3 35 305 1 0 1 0 2.9 0 3.2 2.7 10/22/2004 04:30:00 13.4 0.9 15.3 10.7 13.2 1 15.3 10.3 0.4 0 0.4 0.4 35 4 31 305 1 0 1 0 2.8 0 3.4 2.7 10/22/2004 04:40:00 13.1 1 15.6 10.3 12.8 1 15.3 9.9 0.4 0 0.4 0.4 36 4 35 305 1 0 1 0 2.7 0 2.9 2.7 10/22/2004 04:50:00 13.3 1.1 15.6 10.3 13.1 1.2 15.6 10.3 0.4 0 0.4 0.4 35 4 32 305 1 0 1 0 2.7 0 2.9 2.5 10/22/2004 05:00:00 13.5 1 15.6 10.7 13.4 1 15.6 10.7 0.4 0 0.4 0.4 34 4 30 305 1 0 1 0 2.7 0 3.2 2.7 10/22/2004 05:10:00 13.7 0.8 15.6 11.5 13.5 0.9 15.6 11.1 0.4 0 0.4 0.4 35 3 35 305 1 0 1 0 2.7 0 3.2 2.5 10/22/2004 05:20:00 13.9 0.8 15.6 11.8 13.7 0.9 16.1 11.5 0.4 0 0.4 0.4 33 3 34 305 1 0 1 0 2.7 0 3.2 2.7 10/22/2004 05:30:00 13.5 0.8 15.6 11.1 13.2 0.9 15.6 10.7 0.4 0 0.4 0.4 36 4 35 305 1 0 1 0 2.8 0.1 3.2 2.7 10/22/2004 05:40:00 13.9 0.8 15.6 11.5 13.6 0.9 15.6 11.1 0.4 0 0.4 0.4 35 3 35 305 1 0 1 0 2.7 0 3.2 2.7 10/22/2004 05:50:00 13.5 1 16.1 10.3 13.2 1.1 15.6 10.3 0.4 0 0.4 0.4 35 4 35 305 1 0 1 0 2.8 0.1 3.2 2.7 10/22/2004 06:00:00 13.5 0.9 15.3 10.7 13.3 1 15.6 9.5 0.4 0 0.4 0.4 33 4 32 305 1 0 1 0 2.8 0.1 3.4 2.7 10/22/2004 06:10:00 13.8 0.8 15.3 11.8 13.6 0.9 15.3 11.1 0.4 0 0.4 0.4 30 3 30 305 1 0 1 0 2.7 0 3.2 2.7 10/22/2004 06:20:00 14 1 16.1 11.5 13.7 1 16.1 11.1 0.4 0 0.4 0.4 31 3 31 305 1 0 1 0 2.7 0 3.2 2.7 10/22/2004 06:30:00 13.1 0.8 15.6 11.1 12.8 1 16.1 9.9 0.4 0 0.4 0.4 32 4 29 305 1 0 1 0 2.8 0.1 3.4 2.7 10/22/2004 06:40:00 13.4 1.2 16.1 10.3 13.1 1.2 15.6 10.3 0.4 0 0.4 0.4 31 4 32 305 1 0 1 0 2.8 0.1 3.4 2.7 10/22/2004 06:50:00 13.4 1 15.6 10.3 13.1 1 15.3 9.9 0.4 0 0.4 0.4 28 3 27 305 1 0 1 0 2.8 0.1 3.4 2.7 10/22/2004 07:00:00 13.8 0.8 16.1 11.1 13.6 0.9 16.1 11.5 0.4 0 0.4 0.4 27 4 27 305 1 0 1 0 2.8 0.1 3.4 2.7 10/22/2004 07:10:00 13.8 0.9 15.6 11.1 13.5 1 15.6 10.7 0.4 0 0.4 0.4 29 4 30 305 1 0 1 0 2.9 0.1 3.2 2.7 10/22/2004 07:20:00 13.9 0.9 16.1 11.5 13.8 0.9 16.1 11.1 0.4 0 0.4 0.4 28 4 34 305 1 0 1 0 2.8 0 2.9 2.7 10/22/2004 07:30:00 13.9 1 16.1 10.7 13.7 1.1 16.1 10.3 0.4 0 0.4 0.4 29 3 30 305 1 0 1 0 2.8 0 2.9 2.7 10/22/2004 07:40:00 13.9 1 16.1 11.1 13.6 1 16.1 10.3 0.4 0 0.4 0.4 29 4 28 305 1 0 1 0 2.8 0 3.2 2.7 10/22/2004 07:50:00 13.9 1 16.8 11.1 13.8 1.1 16.8 11.1 0.4 0 0.4 0.4 25 4 23 305 1 0 1 0 2.7 0 3.2 2.5 10/22/2004 08:00:00 13.9 1.2 16.4 10.3 13.8 1.3 17.6 10.7 0.4 0 0.4 0.4 25 4 28 305 1 0 1 0 2.6 0 2.7 2.5 10/22/2004 08:10:00 13.7 1 16.1 10.7 13.6 1.1 16.1 9.9 0.4 0 0.4 0.4 24 4 20 305 1 0 1 0 2.6 0 2.9 2.5 10/22/2004 08:20:00 14.8 1.1 16.8 11.5 14.6 1.2 16.8 10.3 0.4 0 0.4 0.4 28 4 32 305 1 0 0 0 2.5 0 2.9 2.5 10/22/2004 08:30:00 14.4 1 16.4 11.1 14.3 1.1 16.8 11.1 0.4 0 0.4 0.4 25 4 27 305 1 0 1 0 2.5 0 2.9 2.5 10/22/2004 08:40:00 14.4 1 16.4 11.8 14.2 1 16.4 10.7 0.4 0 0.4 0.4 27 4 27 305 1 0 1 0 2.5 0 2.9 2.5 10/22/2004 08:50:00 14.6 0.9 16.8 11.8 14.4 1 16.8 10.7 0.4 0 0.4 0.4 27 3 26 305 1 0 1 0 2.5 0 2.9 2.2 10/22/2004 09:00:00 14.3 1.3 16.8 10.7 14.1 1.3 17.2 10.7 0.4 0 0.4 0.4 26 4 29 305 1 0 1 0 2.5 0 2.9 2.2 10/22/2004 09:10:00 14.6 1.1 17.2 11.8 14.4 1.1 17.2 11.1 0.4 0 0.4 0.4 27 4 26 305 1 0 1 0 2.3 0.1 2.9 2.2 10/22/2004 09:20:00 14.7 1 16.8 11.8 14.5 1.1 16.8 11.5 0.4 0 0.4 0.4 26 3 23 305 1 0 1 0 2.3 0.1 2.7 2.2 10/22/2004 09:30:00 14.8 1.3 17.6 11.5 14.7 1.3 17.9 11.5 0.4 0 0.4 0.4 26 4 28 305 1 0 1 0 2.3 0.1 2.9 2.2 10/22/2004 09:40:00 14.8 1 17.2 11.8 14.6 1.1 16.8 11.5 0.4 0 0.4 0.4 24 4 28 305 1 0 1 0 2.2 0.1 2.7 2.2 10/22/2004 09:50:00 13.7 1.1 16.1 11.1 13.5 1.1 16.1 10.7 0.4 0 0.4 0.4 25 4 29 305 1 0 1 0 2.2 0 2.7 2 10/22/2004 10:00:00 13.9 1 16.4 11.5 13.8 1 16.4 11.5 0.4 0 0.4 0.4 19 4 17 305 1 0 1 0 2 0 2.7 2 10/22/2004 10:10:00 14.9 1 17.2 11.5 14.7 1.2 17.2 11.5 0.4 0 0.4 0.4 19 4 23 305 1 0 1 0 1.9 0 2.5 1.7 10/22/2004 10:20:00 15.2 1.1 17.9 11.5 15.1 1.2 17.9 12.2 0.4 0 0.4 0.4 18 4 21 305 1 0 1 0 1.8 0 2.2 1.5 10/22/2004 10:30:00 14.9 1.1 17.2 11.5 14.7 1.2 17.2 11.5 0.4 0 0.4 0.4 16 4 10 305 1 0 1 0 1.8 0 2.2 1.5 10/22/2004 10:40:00 14.7 1.2 17.6 11.1 14.6 1.2 17.6 11.5 0.4 0 0.4 0.4 15 4 12 305 1 0 1 0 1.7 0.1 2.2 1.5 10/22/2004 10:50:00 15.5 1.1 17.2 11.5 15.4 1.1 17.6 11.8 0.4 0 0.4 0.4 15 3 17 305 1 0 1 0 1.6 0 2.2 1.5 10/22/2004 11:00:00 15.2 1.1 17.2 10.7 15.1 1.2 17.2 11.1 0.4 0 0.4 0.4 14 4 12 305 1 0 1 0 1.6 0 2.2 1.5 10/22/2004 11:10:00 15.3 1 17.6 13 15.3 1.1 17.9 13 0.4 0 0.4 0.4 14 3 11 305 1 0 1 0 1.6 0 2.2 1.5 10/22/2004 11:20:00 15.1 1.2 17.2 11.8 15 1.2 17.6 11.5 0.4 0 0.4 0.4 13 4 10 305 1 0 1 0 1.7 0.1 2.2 1.5 10/22/2004 11:30:00 15.1 1.3 17.9 11.1 15.1 1.4 17.6 11.1 0.4 0 0.4 0.4 13 4 19 305 1 0 1 0 1.7 0.1 2.2 1.5 10/22/2004 11:40:00 14.9 1.3 17.6 11.5 14.8 1.3 17.6 11.5 0.4 0 0.4 0.4 12 4 9 305 1 0 1 0 1.7 0.1 2.5 1.5 10/22/2004 11:50:00 15.5 0.9 17.2 12.6 15.5 1 17.6 12.2 0.4 0 0.4 0.4 13 3 8 305 1 0 1 0 1.7 0.1 2.2 1.5 10/22/2004 12:00:00 14.9 0.9 17.6 12.2 14.9 1 17.6 12.6 0.4 0 0.4 0.4 13 4 13 305 1 0 1 0 1.7 0.1 2.2 1.5 10/22/2004 12:10:00 14.5 1.2 18.3 11.8 14.5 1.3 18.3 11.1 0.4 0 0.4 0.4 12 4 8 305 1 0 1 0 1.8 0.1 2.5 1.5 10/22/2004 12:20:00 14.5 1.2 17.2 11.5 14.4 1.3 17.9 11.1 0.4 0 0.4 0.4 13 4 12 305 1 0 1 0 1.8 0.1 2.5 1.5 10/22/2004 12:30:00 14.6 1.3 17.6 11.5 14.5 1.4 17.9 11.1 0.4 0 0.4 0.4 13 4 15 305 1 0 1 0 1.7 0.1 2.2 1.5 10/22/2004 12:40:00 15.2 1.1 17.9 12.6 15.1 1 18.7 13 0.4 0 0.4 0.4 12 3 7 305 1 0 1 0 1.7 0.1 2.2 1.5 10/22/2004 12:50:00 15.7 1.2 17.9 11.5 15.7 1.3 17.9 11.5 0.4 0 0.4 0.4 12 3 10 305 1 0 1 0 1.6 0 2.2 1.5 10/22/2004 13:00:00 14 1.2 16.8 10.7 14 1.2 16.8 11.1 0.4 0 0.4 0.4 11 4 12 305 1 0 1 0 1.7 0.1 2.2 1.5 10/22/2004 13:10:00 14 1 16.1 11.1 14 1 16.1 11.1 0.4 0 0.4 0.4 8 3 8 305 1 0 1 0 1.6 0 2.2 1.3 10/22/2004 13:20:00 14.4 1 16.8 11.1 14.5 1 17.2 11.5 0.4 0 0.4 0.4 7 4 8 305 1 0 0 0 1.5 0 2 1.3 10/22/2004 13:30:00 14.8 1 16.8 11.8 14.8 1.1 16.8 11.8 0.4 0 0.4 0.4 10 3 3 305 1 0 1 0 1.5 0 2 1.3 10/22/2004 13:40:00 14.1 1.3 16.4 10.7 14.3 1.3 16.8 10.7 0.4 0 0.4 0.4 10 4 9 305 1 0 1 0 1.6 0 2 1.5 10/22/2004 13:50:00 14.1 0.8 16.1 11.8 14.1 1 16.1 11.1 0.4 0 0.4 0.4 10 3 7 305 0 0 0 0 1.6 0 2.2 1.5 10/22/2004 14:00:00 13.8 1.1 16.1 10.3 13.7 1.2 16.4 10.3 0.4 0 0.4 0.4 11 4 11 305 0 0 0 0 1.6 0 2.2 1.5 10/22/2004 14:10:00 13.9 1 16.1 9.9 14 1 16.1 10.7 0.4 0 0.4 0.4 11 3 12 305 0 0 0 0 1.6 0 2.2 1.5 10/22/2004 14:20:00 13.4 0.8 14.9 11.1 13.4 1 15.6 10.7 0.4 0 0.4 0.4 6 4 4 305 0 0 0 0 1.6 0 2.2 1.3 10/22/2004 14:30:00 13.7 0.9 15.6 11.1 13.8 1 16.1 10.7 0.4 0 0.4 0.4 4 3 2 305 0 0 0 0 1.4 0 2 1.3 10/22/2004 14:40:00 13.4 1 15.6 10.7 13.6 1 15.3 10.7 0.4 0 0.4 0.4 6 3 9 305 0 0 0 0 1.4 0 2 1.3 10/22/2004 14:50:00 12.9 1 15.3 9.9 13 1.1 15.6 9.5 0.4 0 0.4 0.4 7 3 7 305 0 0 0 0 1.4 0 2 1.3 10/22/2004 15:00:00 13.2 0.7 14.9 11.5 13.3 0.8 15.3 11.1 0.4 0 0.4 0.4 7 4 14 305 0 0 0 0 1.4 0 2 1.3 10/22/2004 15:10:00 12.4 1 14.9 9.1 12.6 1.1 15.3 9.5 0.4 0 0.4 0.4 7 4 12 305 0 0 0 0 1.3 0 2 1.3 10/22/2004 15:20:00 12.3 0.9 14.9 9.9 12.4 0.9 14.9 10.3 0.4 0 0.4 0.4 7 4 10 305 0 0 0 0 1.4 0 2 1.3 10/22/2004 15:30:00 12.1 0.9 14.1 9.5 12.1 1 14.5 8.8 0.4 0 0.4 0.4 7 4 7 305 0 0 0 0 1.5 0 2.2 1.3 10/22/2004 15:40:00 12.4 0.9 14.1 9.5 12.4 1 14.9 9.1 0.4 0 0.4 0.4 2 5 9 305 0 0 0 0 1.2 0.2 2 1 10/22/2004 15:50:00 12.3 0.8 14.5 9.5 12.5 0.9 14.5 9.5 0.4 0 0.4 0.4 0 4 7 305 0 0 0 0 1 0 1.5 0.8 10/22/2004 16:00:00 12.2 0.6 13.3 9.9 12.3 0.7 13.7 9.9 0.4 0 0.4 0.4 0 3 1 305 0 0 0 0 0.9 0 1.5 0.8 10/22/2004 16:10:00 11.9 0.8 13.7 9.5 12 0.9 14.1 9.1 0.4 0 0.4 0.4 3 5 356 305 0 0 0 0 1 0.1 1.5 0.8 10/22/2004 16:20:00 12 0.8 14.1 9.1 12 0.9 13.7 9.1 0.4 0 0.4 0.4 9 3 4 305 1 0 1 0 1.2 0.1 2 1 10/22/2004 16:30:00 12.4 0.8 14.1 10.3 12.4 0.9 14.5 9.9 0.4 0 0.4 0.4 8 3 16 305 1 0 1 0 1.1 0.1 1.5 1 10/22/2004 16:40:00 12.1 0.7 13.7 9.9 12.2 0.8 14.1 10.3 0.4 0 0.4 0.4 8 4 11 305 1 0 0 0 1.2 0.1 1.5 1 10/22/2004 16:50:00 12.2 0.6 13.3 9.9 12.2 0.7 13.7 9.5 0.4 0 0.4 0.4 7 3 9 305 0 0 1 0 1.1 0.1 1.5 1 10/22/2004 17:00:00 11.6 0.9 13 9.1 11.6 0.9 13.3 9.1 0.4 0 0.4 0.4 9 3 10 305 0 0 0 0 1.2 0.1 1.7 1 10/22/2004 17:10:00 11.7 0.8 13.3 9.5 11.8 0.8 13.3 9.1 0.4 0 0.4 0.4 13 4 15 305 0 0 0 0 1.2 0.1 1.7 1 10/22/2004 17:20:00 11.7 1.1 13.7 8.8 11.7 1.2 14.5 8.8 0.4 0 0.4 0.4 11 6 6 305 0 0 0 0 1.3 0.1 2 1 10/22/2004 17:30:00 11.3 0.8 13 8.8 11.5 0.9 13.3 8.4 0.4 0 0.4 0.4 10 4 11 305 0 0 0 0 1.4 0 2 1.3 10/22/2004 17:40:00 11.7 1 13.7 9.1 11.8 1 14.1 8.8 0.4 0 0.4 0.4 11 5 6 305 0 0 0 0 1.3 0.1 2 1.3 10/22/2004 17:50:00 11.2 0.8 13 9.1 11.2 0.8 13 8.8 0.4 0 0.4 0.4 11 5 13 305 0 0 0 0 1.3 0.1 2 1.3 10/22/2004 18:00:00 11.5 0.8 13.7 9.1 11.5 0.9 14.1 8.8 0.4 0 0.4 0.4 14 4 12 305 0 0 0 0 1.4 0 2 1.3 10/22/2004 18:10:00 11.5 0.8 13.3 9.5 11.5 0.9 13.7 9.5 0.4 0 0.4 0.4 14 5 18 305 0 0 0 0 1.2 0.1 2 1 10/22/2004 18:20:00 11.1 0.8 13 8.4 11.1 0.9 13 8 0.4 0 0.4 0.4 14 3 18 305 0 0 0 0 1.2 0.1 1.5 1 10/22/2004 18:30:00 10.8 0.7 12.2 8.8 10.8 0.7 12.6 8.8 0.4 0 0.4 0.4 16 4 16 305 0 0 0 0 1.1 0 1.5 1 10/22/2004 18:40:00 10.6 0.6 12.2 9.1 10.6 0.6 12.6 8.4 0.4 0 0.4 0.4 12 6 5 305 0 0 0 0 1 0 1.5 1 10/22/2004 18:50:00 10.4 0.9 12.2 8 10.5 0.9 12.6 8 0.4 0 0.4 0.4 16 4 10 305 0 0 0 0 1 0 1.5 0.8 10/22/2004 19:00:00 10.2 0.7 11.8 8.4 10.3 0.8 12.2 8 0.4 0 0.4 0.4 15 4 17 305 0 0 0 0 1 0 1.5 0.8 10/22/2004 19:10:00 10.2 0.6 11.8 8 10.3 0.7 11.8 8.4 0.4 0 0.4 0.4 12 5 8 305 0 0 0 0 1 0 1.5 0.8 10/22/2004 19:20:00 9.8 0.6 11.8 8 9.8 0.7 11.5 7.6 0.4 0 0.4 0.4 14 5 19 305 0 0 0 0 0.9 0 1.5 0.8 10/22/2004 19:30:00 10 0.8 12.2 8 10.2 0.9 12.6 8 0.4 0 0.4 0.4 13 5 13 305 0 0 0 0 0.9 0.1 1.5 0.6 10/22/2004 19:40:00 9.9 0.7 11.8 8 9.9 0.8 11.5 6.8 0.4 0 0.4 0.4 9 5 7 305 0 0 0 0 0.9 0 1.3 0.8 10/22/2004 19:50:00 10.1 0.6 11.5 8.4 10.1 0.7 12.2 8 0.4 0 0.4 0.4 15 5 9 305 0 0 0 0 0.8 0 1.3 0.6 10/22/2004 20:00:00 10.2 0.6 11.5 8.4 10.2 0.7 11.8 8 0.4 0 0.4 0.4 17 4 16 305 0 0 0 0 0.9 0 1.5 0.8 10/22/2004 20:10:00 9.8 0.6 11.5 7.6 9.8 0.6 11.1 7.6 0.4 0 0.4 0.4 17 5 15 305 0 0 0 0 0.9 0 1.5 0.8 10/22/2004 20:20:00 10 0.7 11.5 7.6 10 0.7 11.5 7.6 0.4 0 0.4 0.4 14 4 14 305 0 0 0 0 0.9 0 1.5 0.8 10/22/2004 20:30:00 10 0.6 11.5 8.4 10.1 0.6 11.5 8 0.4 0 0.4 0.4 16 5 21 305 0 0 0 0 0.9 0 1.3 0.8 10/22/2004 20:40:00 9.8 0.5 11.5 8.4 9.8 0.5 11.1 8 0.4 0 0.4 0.4 19 4 18 305 0 0 0 0 1 0 1.5 0.8 10/22/2004 20:50:00 9.6 0.7 11.1 7.6 9.7 0.7 11.1 7.2 0.4 0 0.4 0.4 15 4 16 305 0 0 0 0 0.9 0 1.5 0.8 10/22/2004 21:00:00 9.8 0.6 11.1 8 9.9 0.6 11.5 8 0.4 0 0.4 0.4 14 5 9 305 0 0 0 0 0.9 0 1.3 0.8 10/22/2004 21:10:00 9.8 0.7 11.5 7.6 9.7 0.7 11.5 7.6 0.4 0 0.4 0.4 14 5 11 305 0 0 0 0 1 0 1.5 0.8 10/22/2004 21:20:00 10.1 0.6 11.8 8.4 10.1 0.7 11.8 8 0.4 0 0.4 0.4 13 5 18 305 0 0 0 0 0.9 0 1.5 0.8 10/22/2004 21:30:00 10 0.6 11.5 8.4 10 0.6 11.8 8.8 0.4 0 0.4 0.4 15 4 13 305 0 0 0 0 1 0 1.5 0.8 10/22/2004 21:40:00 9.6 0.7 11.5 7.6 9.6 0.8 11.8 7.6 0.4 0 0.4 0.4 20 5 24 305 0 0 0 0 1 0 1.5 1 10/22/2004 21:50:00 9.5 0.8 11.5 7.2 9.6 0.8 11.5 6.8 0.4 0 0.4 0.4 18 4 21 305 0 0 0 0 1 0 1.5 0.8 10/22/2004 22:00:00 9.5 0.8 11.5 6.8 9.6 0.8 11.8 7.2 0.4 0 0.4 0.4 13 6 20 305 0 0 0 0 1 0 1.5 1 10/22/2004 22:10:00 9.4 1 11.8 6.8 9.5 1 12.2 7.2 0.4 0 0.4 0.4 13 6 11 305 0 0 0 0 1 0 1.5 0.8 10/22/2004 22:20:00 9.5 0.7 11.1 7.6 9.6 0.8 11.5 7.2 0.4 0 0.4 0.4 10 5 12 305 0 0 0 0 0.9 0 1.5 0.8 10/22/2004 22:30:00 9.3 0.8 11.8 7.2 9.4 0.8 11.8 7.6 0.4 0 0.4 0.4 9 5 10 305 0 0 0 0 0.9 0 1.5 0.8 10/22/2004 22:40:00 10.1 0.8 11.8 8 10.2 0.8 12.2 8 0.4 0 0.4 0.4 10 5 17 305 0 0 0 0 1 0 1.5 0.8 10/22/2004 22:50:00 10.3 0.7 11.8 8 10.4 0.7 12.2 8.4 0.4 0 0.4 0.4 11 4 14 305 0 0 0 0 0.9 0 1.5 0.8 10/22/2004 23:00:00 10.6 0.8 12.6 8.4 10.7 0.9 13 8.4 0.4 0 0.4 0.4 12 4 13 305 0 0 0 0 0.8 0 1.3 0.6 10/22/2004 23:10:00 10.2 1.1 12.6 8 10.3 1.1 12.2 7.6 0.4 0 0.4 0.4 17 4 21 305 0 0 0 0 0.9 0 1.5 0.6 10/22/2004 23:20:00 10.4 0.7 12.2 8.4 10.5 0.7 13 8.8 0.4 0 0.4 0.4 14 5 8 305 0 0 0 0 0.9 0 1.3 0.8 10/22/2004 23:30:00 9.9 0.8 12.6 8 9.9 0.9 12.6 7.2 0.4 0 0.4 0.4 16 6 21 305 0 0 0 0 1 0 1.5 0.8 10/22/2004 23:40:00 10.5 0.8 12.6 8.8 10.6 0.9 13 8.4 0.4 0 0.4 0.4 11 4 10 305 0 0 0 0 1.1 0 1.5 1 10/22/2004 23:50:00 10.5 0.8 12.6 8 10.7 0.9 13 8.4 0.4 0 0.4 0.4 6 5 9 305 0 0 0 0 1.1 0 1.5 1 10/23/2004 00:00:00 10 0.9 11.8 7.6 10.2 0.9 12.2 8 0.4 0 0.4 0.4 9 5 10 305 0 0 0 0 1.2 0 1.5 1 10/23/2004 00:10:00 10.9 0.7 13.3 9.1 11 0.7 13.3 9.1 0.4 0 0.4 0.4 9 4 10 305 0 0 0 0 1.3 0 1.7 1 10/23/2004 00:20:00 10.7 0.9 13.3 8.8 10.8 0.9 13.7 8.8 0.4 0 0.4 0.4 16 7 20 305 0 0 0 0 1.3 0 2 1 10/23/2004 00:30:00 10.1 0.7 12.2 8 10.2 0.7 11.8 8.4 0.4 0 0.4 0.4 11 6 12 305 0 0 0 0 1.3 0 2 1.3 10/23/2004 00:40:00 11.1 0.9 13.3 9.1 11.2 1 13.3 9.1 0.4 0 0.4 0.4 7 5 16 305 0 0 0 0 1.2 0.1 1.5 1 10/23/2004 00:50:00 11 0.8 13.7 8.8 11.1 0.9 13.3 8.8 0.4 0 0.4 0.4 9 4 4 305 0 0 0 0 0.9 0 1.3 0.8 10/23/2004 01:00:00 11.3 0.8 13.3 9.1 11.4 0.8 13.7 8.8 0.4 0 0.4 0.4 14 6 18 305 0 0 0 0 1.2 0.1 1.5 1 10/23/2004 01:10:00 10.5 1.1 13.3 8.4 10.5 1.2 13.7 7.6 0.4 0 0.4 0.4 14 5 18 305 0 0 0 0 1.1 0 1.5 1 10/23/2004 01:20:00 10.9 1.1 13.3 8 11 1.2 13.7 8 0.4 0 0.4 0.4 7 6 4 305 0 0 0 0 1.1 0 1.5 1 10/23/2004 01:30:00 11 0.7 12.6 8.8 11.2 0.8 13 9.1 0.4 0 0.4 0.4 3 4 357 305 0 0 0 0 1 0 1.5 1 10/23/2004 01:40:00 11.6 0.9 14.5 9.5 11.7 1 14.5 9.5 0.4 0 0.4 0.4 8 4 11 305 0 0 0 0 1.1 0 1.5 1 10/23/2004 01:50:00 10.6 0.8 12.6 8.8 10.8 0.9 13.3 8.4 0.4 0 0.4 0.4 11 5 12 305 0 0 0 0 1.1 0 1.5 1 10/23/2004 02:00:00 10.3 0.9 13 8.4 10.3 1 13.3 7.6 0.4 0 0.4 0.4 13 5 13 305 0 0 0 0 1.1 0 1.5 1 10/23/2004 02:10:00 10.2 0.8 12.2 8.4 10.3 0.8 12.6 8.4 0.4 0 0.4 0.4 8 5 5 305 0 0 0 0 1 0 1.3 1 10/23/2004 02:20:00 10.5 0.8 13 8 10.5 0.9 12.6 7.6 0.4 0 0.4 0.4 12 5 15 305 0 0 0 0 1 0 1.5 1 10/23/2004 02:30:00 11.3 1 13.3 8.8 11.5 1.1 13.3 8.8 0.4 0 0.4 0.4 7 4 3 305 0 0 0 0 1 0 1.5 1 10/23/2004 02:40:00 11.3 1 13.7 7.2 11.4 1.1 14.1 8.4 0.4 0 0.4 0.4 7 4 5 305 0 0 0 0 1 0 1.3 0.8 10/23/2004 02:50:00 11.1 1 13.3 8.4 11.2 1.1 14.1 8.4 0.4 0 0.4 0.4 7 4 6 305 0 0 0 0 1 0 1.5 0.8 10/23/2004 03:00:00 11.2 0.8 13 9.1 11.2 0.8 13.3 8.8 0.4 0 0.4 0.4 8 5 5 305 0 0 0 0 1 0 1.3 0.8 10/23/2004 03:10:00 11.2 0.8 13.7 9.1 11.4 0.9 14.5 8.8 0.4 0 0.4 0.4 6 5 9 305 0 0 0 0 1 0 1.5 0.8 10/23/2004 03:20:00 10.6 0.9 13 8.8 10.7 1 13.3 8 0.4 0 0.4 0.4 6 6 2 305 0 0 0 0 0.9 0 1.3 0.8 10/23/2004 03:30:00 11.2 0.8 13.7 9.1 11.3 0.9 14.1 8.4 0.4 0 0.4 0.4 359 5 357 305 0 0 0 0 0.9 0 1.5 0.6 10/23/2004 03:40:00 11.4 0.8 13.3 9.1 11.6 0.9 13.3 9.5 0.4 0 0.4 0.4 356 4 351 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 03:50:00 11.6 0.8 13.7 9.5 11.9 0.9 14.1 9.5 0.4 0 0.4 0.4 356 3 357 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 04:00:00 10.8 0.9 13.3 8.8 11.1 0.9 13.7 8.8 0.4 0 0.4 0.4 358 5 358 305 0 0 0 0 0.8 0 1.3 0.6 10/23/2004 04:10:00 11.6 0.6 13.3 9.5 11.9 0.7 13.7 9.9 0.4 0 0.4 0.4 358 3 358 305 0 0 0 0 0.8 0 1.3 0.6 10/23/2004 04:20:00 11.8 0.9 13.7 9.1 12 1 13.7 8.8 0.4 0 0.4 0.4 358 4 353 305 0 0 0 0 0.8 0.1 1.3 0.6 10/23/2004 04:30:00 12 0.8 13.7 9.9 12.3 0.9 14.1 9.5 0.4 0 0.4 0.4 357 4 355 305 0 0 0 0 0.7 0 1.3 0.6 10/23/2004 04:40:00 11.5 0.8 13.3 9.5 11.8 0.9 14.1 9.1 0.4 0 0.4 0.4 356 4 358 305 0 0 0 0 0.8 0 1.3 0.6 10/23/2004 04:50:00 12.4 0.8 14.1 10.3 12.6 0.9 14.5 9.9 0.4 0 0.4 0.4 356 3 356 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 05:00:00 12.5 0.8 14.5 9.9 12.7 0.8 14.5 9.9 0.4 0 0.4 0.4 358 4 358 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 05:10:00 12.3 1 14.1 9.1 12.5 1.1 14.5 9.5 0.4 0 0.4 0.4 354 4 352 305 0 0 0 0 0.6 0.1 1.3 0.6 10/23/2004 05:20:00 12.2 1 14.1 9.5 12.4 1 14.9 9.5 0.4 0 0.4 0.4 357 4 355 305 0 0 0 0 0.7 0 1.3 0.6 10/23/2004 05:30:00 12.6 1 14.9 10.3 12.8 1 15.3 9.9 0.4 0 0.4 0.4 353 4 351 305 0 0 0 0 0.7 0 1.3 0.6 10/23/2004 05:40:00 12.2 1.1 14.5 9.5 12.4 1.1 15.3 9.1 0.4 0 0.4 0.4 353 5 355 305 0 0 0 0 0.7 0 1.3 0.6 10/23/2004 05:50:00 12.4 0.9 14.5 9.5 12.7 0.9 14.9 9.9 0.4 0 0.4 0.4 354 4 0 305 0 0 0 0 0.7 0 1.3 0.6 10/23/2004 06:00:00 12.6 0.8 14.5 10.3 12.9 1 15.3 10.3 0.4 0 0.4 0.4 354 5 359 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 06:10:00 12.8 0.8 14.5 9.9 13.1 0.9 14.9 10.7 0.4 0 0.4 0.4 354 4 355 305 0 0 0 0 0.6 0.1 1 0.6 10/23/2004 06:20:00 12.4 0.8 14.1 9.9 12.6 0.9 14.5 9.9 0.4 0 0.4 0.4 353 4 355 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 06:30:00 13 0.8 14.9 10.7 13.2 0.8 14.9 11.1 0.4 0 0.4 0.4 353 4 357 305 0 0 0 0 0.6 0.1 1.3 0.6 10/23/2004 06:40:00 13.1 0.8 14.9 10.7 13.3 1 15.6 10.7 0.4 0 0.4 0.4 353 4 352 305 0 0 0 0 0.6 0.1 1 0.6 10/23/2004 06:50:00 13 1 15.3 9.9 13.3 1 15.6 10.3 0.4 0 0.4 0.4 355 4 357 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 07:00:00 13.2 1.1 15.3 10.3 13.5 1.2 15.6 10.3 0.4 0 0.4 0.4 353 4 355 305 0 0 0 0 0.6 0.1 1.3 0.6 10/23/2004 07:10:00 13.2 0.9 15.6 9.9 13.4 1 15.6 10.3 0.4 0 0.4 0.4 355 3 355 305 0 0 0 0 0.6 0.1 1.3 0.6 10/23/2004 07:20:00 12.9 0.9 14.5 9.5 13.1 1 14.9 10.7 0.4 0 0.4 0.4 357 5 357 305 0 0 0 0 0.6 0.1 1 0.6 10/23/2004 07:30:00 12.4 1 14.5 9.5 12.6 1 14.9 9.9 0.4 0 0.4 0.4 356 4 2 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 07:40:00 12.4 0.9 14.1 10.3 12.6 1 14.5 9.9 0.4 0 0.4 0.4 355 4 344 305 0 0 0 0 0.8 0 1.3 0.6 10/23/2004 07:50:00 12.6 1 15.3 10.3 12.9 1 15.3 10.3 0.4 0 0.4 0.4 355 4 349 305 0 0 0 0 0.9 0 1.3 0.6 10/23/2004 08:00:00 12.1 0.8 14.1 9.5 12.2 0.9 14.1 9.9 0.4 0 0.4 0.4 356 4 352 305 0 0 0 0 0.9 0 1 0.8 10/23/2004 08:10:00 12.2 0.8 13.7 9.1 12.4 0.9 14.1 9.1 0.4 0 0.4 0.4 353 4 355 305 0 0 0 0 0.7 0 1.3 0.6 10/23/2004 08:20:00 12 0.9 14.5 9.5 12.3 1 14.9 9.5 0.4 0 0.4 0.4 352 5 346 305 0 0 0 0 0.6 0.1 1 0.6 10/23/2004 08:30:00 11.9 0.8 13.7 9.1 12.1 0.9 14.5 9.5 0.4 0 0.4 0.4 348 5 348 305 0 0 0 0 0.5 0 1 0.6 10/23/2004 08:40:00 12 0.9 13.7 9.5 12.3 1 14.1 9.5 0.4 0 0.4 0.4 350 5 341 305 0 0 0 0 0.5 0 1.3 0.6 10/23/2004 08:50:00 11.7 1 13.7 9.1 12 1 14.1 9.1 0.4 0 0.4 0.4 350 4 351 305 0 0 0 0 0.6 0 1 0.6 10/23/2004 09:00:00 11.6 1 13.7 8.4 11.8 1.1 14.5 8.4 0.4 0 0.4 0.4 349 4 347 305 0 0 0 0 0.5 0 0.6 0.6 10/23/2004 09:10:00 11.5 0.8 13 9.5 11.8 1 13.7 9.1 0.4 0 0.4 0.4 353 4 351 305 0 0 0 0 0.5 0 1 0.6 10/23/2004 09:20:00 12.1 0.8 14.5 10.3 12.3 0.9 14.5 9.1 0.4 0 0.4 0.4 351 5 344 305 0 0 0 0 0.5 0 1 0.3 10/23/2004 09:30:00 12 0.8 14.1 9.9 12.3 1 14.5 9.5 0.4 0 0.4 0.4 348 4 350 305 0 0 0 0 0.5 0 1 0.3 10/23/2004 09:40:00 11.9 0.7 13.7 9.9 12.2 0.8 14.1 10.3 0.4 0 0.4 0.4 348 4 342 305 0 0 0 0 0.4 0 1 0.3 10/23/2004 09:50:00 11.6 0.8 13.3 8.8 11.9 0.8 13.7 9.9 0.4 0 0.4 0.4 342 4 337 305 0 0 0 0 0.4 0 1 0.3 10/23/2004 10:00:00 11.4 0.8 13.3 8.8 11.6 0.9 14.1 9.1 0.4 0 0.4 0.4 336 5 335 305 0 0 0 0 0.4 0 0.8 0.3 10/23/2004 10:10:00 11.6 0.8 13.3 8.8 11.8 0.9 13.7 9.1 0.4 0 0.4 0.4 332 4 337 305 0 0 0 0 0.4 0 0.8 0.3 10/23/2004 10:20:00 11.1 1.1 13.7 8.4 11.2 1.1 13.7 8.4 0.4 0 0.4 0.4 331 5 326 305 0 0 0 0 0.4 0 1 0.3 10/23/2004 10:30:00 11.6 0.9 13.3 8.8 11.8 1 13.7 9.1 0.4 0 0.4 0.4 332 5 328 305 0 0 0 0 0.4 0 0.8 0.3 10/23/2004 10:40:00 11.5 0.6 13 9.5 11.9 0.7 13.3 9.5 0.4 0 0.4 0.4 335 4 329 305 0 0 0 0 0.4 0 1 0.3 10/23/2004 10:50:00 11.1 0.7 13 8.8 11.4 0.8 13.3 9.1 0.4 0 0.4 0.4 335 5 336 305 0 0 0 0 0.5 0 1 0.6 10/23/2004 11:00:00 11.6 0.8 13.3 9.1 11.9 0.9 14.1 9.1 0.4 0 0.4 0.4 336 4 338 305 0 0 0 0 0.6 0 1 0.6 10/23/2004 11:10:00 12.2 0.8 13.7 9.1 12.5 0.9 14.5 9.5 0.4 0 0.4 0.4 335 4 336 305 0 0 0 0 0.5 0 1 0.3 10/23/2004 11:20:00 12.1 0.9 14.1 9.5 12.3 1 14.5 9.1 0.4 0 0.4 0.4 334 5 336 305 0 0 0 0 0.5 0 1 0.3 10/23/2004 11:30:00 12.1 1 13.7 8.4 12.4 1.1 14.1 8.4 0.4 0 0.4 0.4 334 4 329 305 0 0 0 0 0.5 0 1 0.3 10/23/2004 11:40:00 11.5 0.8 13 9.5 11.8 1 13.3 9.1 0.4 0 0.4 0.4 334 4 337 305 0 0 0 0 0.5 0 1 0.6 10/23/2004 11:50:00 11.3 0.9 13.3 8.8 11.5 1 13.3 8.4 0.4 0 0.4 0.4 334 5 338 305 0 0 0 0 0.5 0 1 0.6 10/23/2004 12:00:00 11.6 1 13.3 8 11.8 1.2 14.1 8.4 0.4 0 0.4 0.4 334 5 334 305 0 0 0 0 0.5 0 1 0.6 10/23/2004 12:10:00 11.7 0.9 13.7 9.5 11.9 0.9 13.7 9.5 0.4 0 0.4 0.4 334 5 330 305 0 0 0 0 0.6 0.1 1 0.6 10/23/2004 12:20:00 11.5 0.9 13.3 9.1 11.9 1 14.1 9.1 0.4 0 0.4 0.4 336 4 328 305 0 0 0 0 0.6 0.1 1 0.6 10/23/2004 12:30:00 11.4 0.8 13 9.1 11.6 0.9 13.7 8.8 0.4 0 0.4 0.4 339 5 345 305 0 0 0 0 0.6 0.1 1 0.6 10/23/2004 12:40:00 11.1 0.8 13 8.8 11.4 1 13.3 8.4 0.4 0 0.4 0.4 341 5 347 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 12:50:00 10.7 1 13 8 11 1.1 13.3 8 0.4 0 0.4 0.4 341 5 335 305 0 0 0 0 0.8 0 1.3 0.6 10/23/2004 13:00:00 11.4 0.6 12.6 9.5 11.7 0.7 13.3 9.5 0.4 0 0.4 0.4 341 4 341 305 0 0 0 0 0.9 0 1 0.8 10/23/2004 13:10:00 11.4 0.6 12.6 9.1 11.8 0.7 13.3 9.5 0.4 0 0.4 0.4 344 3 345 305 0 0 0 0 0.9 0 1.5 0.8 10/23/2004 13:20:00 10.7 1 12.6 8 11 1 13 8.4 0.4 0 0.4 0.4 344 5 349 305 0 0 0 0 1 0 1.3 1 10/23/2004 13:30:00 10.7 0.6 12.2 8.8 11 0.7 12.6 8.8 0.4 0 0.4 0.4 345 5 346 305 0 0 0 0 1.1 0 1.5 1 10/23/2004 13:40:00 10.5 0.6 11.8 8.8 10.9 0.7 12.2 8.4 0.4 0 0.4 0.4 344 4 339 305 0 0 0 0 1.1 0 1.5 1 10/23/2004 13:50:00 10 0.8 12.2 7.6 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 349 4 344 305 0 0 0 0 1.2 0.1 1.7 1 10/23/2004 14:00:00 10.3 0.6 11.8 8 10.7 0.8 12.2 8 0.4 0 0.4 0.4 346 3 345 305 0 0 0 0 1.2 0.1 1.5 1 10/23/2004 14:10:00 9.9 0.8 11.8 7.2 10.2 1 12.2 7.6 0.4 0 0.4 0.4 345 4 340 305 0 0 0 0 1.2 0.1 1.7 1 10/23/2004 14:20:00 9.4 0.7 11.5 7.6 9.7 0.8 11.8 7.6 0.4 0 0.4 0.4 347 4 344 305 0 0 0 0 1.3 0 2 1.3 10/23/2004 14:30:00 9.5 0.6 10.7 7.6 9.7 0.6 11.1 7.6 0.4 0 0.4 0.4 347 4 350 305 0 0 0 0 1.5 0 2 1.3 10/23/2004 14:40:00 9.4 0.6 10.7 7.2 9.7 0.7 11.5 7.6 0.4 0 0.4 0.4 345 4 344 305 0 0 0 0 1.4 0 2 1.3 10/23/2004 14:50:00 9 0.6 10.3 6.8 9.3 0.6 11.1 7.6 0.4 0 0.4 0.4 342 4 340 305 0 0 0 0 1.4 0 2 1.3 10/23/2004 15:00:00 8.7 0.8 10.7 6.1 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 343 5 343 305 0 0 0 0 1.4 0 2 1.3 10/23/2004 15:10:00 9.1 0.5 10.3 7.2 9.4 0.6 11.1 7.2 0.4 0 0.4 0.4 338 4 340 305 0 0 0 0 1.4 0 2 1.3 10/23/2004 15:20:00 9.2 0.7 10.7 7.2 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 339 4 336 305 0 0 0 0 1.5 0 2 1.3 10/23/2004 15:30:00 9.5 1 12.2 6.8 9.8 1 12.6 6.8 0.4 0 0.4 0.4 343 5 337 305 0 0 0 0 1.6 0.1 2.2 1.3 10/23/2004 15:40:00 9.6 0.8 11.5 6.8 9.9 0.9 12.2 6.8 0.4 0 0.4 0.4 340 5 340 305 0 0 0 0 1.6 0 2.2 1.3 10/23/2004 15:50:00 9.9 0.6 11.5 8 10.3 0.7 12.2 7.6 0.4 0 0.4 0.4 343 5 341 305 0 0 0 0 1.7 0.2 2.2 1.5 10/23/2004 16:00:00 10 0.8 11.8 8.4 10.3 0.9 12.6 8.4 0.4 0 0.4 0.4 347 4 346 305 0 0 0 0 1.6 0 2.2 1.5 10/23/2004 16:10:00 10 0.8 12.2 7.6 10.2 0.9 13 7.6 0.4 0 0.4 0.4 338 6 335 305 0 0 0 0 1.3 0.2 2 1 10/23/2004 16:20:00 10 1 11.8 7.2 10.3 1 12.6 6.8 0.4 0 0.4 0.4 344 5 351 305 0 0 0 0 1.4 0.1 2 1 10/23/2004 16:30:00 10.4 1 12.6 8 10.7 1 13 8 0.4 0 0.4 0.4 348 3 352 305 0 0 0 0 1.3 0.1 1.7 1.3 10/23/2004 16:40:00 11.8 1 13.7 8.8 12 1.1 14.5 8.8 0.4 0 0.4 0.4 348 8 350 305 0 0 0 0 1.2 0.1 1.7 1 10/23/2004 16:50:00 12.8 1 14.9 9.9 13.1 1 15.6 10.3 0.4 0 0.4 0.4 340 4 339 305 0 0 0 0 0.8 0.1 1.5 0.6 10/23/2004 17:00:00 13.1 1 14.9 10.3 13.4 1 15.3 9.5 0.4 0 0.4 0.4 342 5 344 305 0 0 0 0 0.9 0 1.5 0.8 10/23/2004 17:10:00 13.1 1.1 15.3 10.3 13.3 1.2 16.1 9.9 0.4 0 0.4 0.4 340 5 345 305 0 0 0 0 0.9 0.2 1.5 0.6 10/23/2004 17:20:00 12.3 0.8 14.1 9.9 12.6 0.9 14.5 10.3 0.4 0 0.4 0.4 338 5 339 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 17:30:00 12.6 0.8 14.5 9.9 12.8 1 14.9 10.3 0.4 0 0.4 0.4 338 4 341 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 17:40:00 11.9 0.8 13.3 9.5 12.3 1 13.7 9.5 0.4 0 0.4 0.4 341 4 340 305 0 0 0 0 0.7 0.1 1.3 0.6 10/23/2004 17:50:00 11.9 0.8 13.7 9.1 12.1 1 14.1 9.1 0.4 0 0.4 0.4 344 4 338 305 0 0 0 0 0.5 0 1 0.3 10/23/2004 18:00:00 12.3 0.8 14.1 9.5 12.6 1 14.9 9.9 0.4 0 0.4 0.4 341 4 336 305 0 0 0 0 0.6 0 1.3 0.6 10/23/2004 18:10:00 11.7 1 14.1 8.8 12 1 14.5 9.1 0.4 0 0.4 0.4 345 6 340 305 0 0 0 0 0.6 0 1 0.6 10/23/2004 18:20:00 10.8 0.8 13 8.8 11.1 0.9 13.3 8.8 0.4 0 0.4 0.4 347 5 353 305 0 0 0 0 0.6 0 1 0.6 10/23/2004 18:30:00 11.9 0.9 14.1 9.5 12.2 1 14.9 8.8 0.4 0 0.4 0.4 342 4 346 305 0 0 0 0 0.6 0 1 0.6 10/23/2004 18:40:00 11.6 0.9 13.3 8.8 11.9 0.9 13.7 8.8 0.4 0 0.4 0.4 344 6 336 305 0 0 0 0 0.6 0 1 0.6 10/23/2004 18:50:00 11.5 0.8 13.7 8.4 11.7 0.9 13.7 8.8 0.4 0 0.4 0.4 341 10 337 305 0 0 0 0 0.7 0.1 1 0.6 10/23/2004 19:00:00 10.9 1.3 13.7 8 11 1.4 14.1 7.6 0.4 0 0.4 0.4 329 6 331 305 0 0 0 0 0.5 0 1 0.6 10/23/2004 19:10:00 11 1.2 14.1 8 11 1.2 14.1 8.4 0.4 0 0.4 0.4 325 8 329 305 0 0 0 0 0.5 0 1 0.3 10/23/2004 19:20:00 11.1 0.9 13.7 8.8 11.2 0.9 13.3 8.8 0.4 0 0.4 0.4 331 6 321 305 0 0 0 0 0.5 0 1 0.6 10/23/2004 19:30:00 10.1 1.1 13 7.2 10.3 1.3 12.6 6.8 0.4 0 0.4 0.4 334 4 325 305 0 0 0 0 0.5 0 1 0.6 10/23/2004 19:40:00 9.5 0.8 11.1 7.2 9.6 0.9 11.5 7.2 0.4 0 0.4 0.4 330 6 324 305 0 0 0 0 0.5 0 1 0.6 10/23/2004 19:50:00 9.9 0.9 13 8 10.1 0.9 13.3 7.6 0.4 0 0.4 0.4 332 6 320 305 0 0 0 0 0.6 0.1 1 0.6 10/23/2004 20:00:00 11.3 0.8 13 8.8 11.5 0.8 13.3 8.4 0.4 0 0.4 0.4 331 5 330 305 0 0 0 0 0.7 0 0.8 0.6 10/23/2004 20:10:00 10.4 0.9 12.6 8 10.6 0.9 13 8.4 0.4 0 0.4 0.4 332 5 334 305 0 0 0 0 0.7 0 1 0.6 10/23/2004 20:20:00 10.7 0.8 12.6 8.8 10.8 0.8 12.6 8.8 0.4 0 0.4 0.4 327 5 325 305 0 0 0 0 0.9 0 1.5 0.8 10/23/2004 20:30:00 11.3 1 13 8 11.3 1.1 13.7 7.2 0.4 0 0.4 0.4 328 5 320 305 0 0 0 0 1 0 1.5 0.8 10/23/2004 20:40:00 10.4 0.9 12.2 8 10.6 1 13 8 0.4 0 0.4 0.4 327 5 332 305 0 0 0 0 1 0 1.3 0.8 10/23/2004 20:50:00 9.3 0.8 11.8 7.2 9.4 1 11.8 7.2 0.4 0 0.4 0.4 326 6 327 305 0 0 0 0 1 0 1.5 1 10/23/2004 21:00:00 9.9 0.8 12.2 8 9.9 0.8 11.8 8 0.4 0 0.4 0.4 323 7 309 305 0 0 0 0 1 0 1.5 0.8 10/23/2004 21:10:00 10.5 0.8 13 8.4 10.7 1 13.3 7.6 0.4 0 0.4 0.4 327 5 331 305 0 0 0 0 1 0 1.5 0.8 10/23/2004 21:20:00 10.6 0.8 13 8 10.7 1 13 8 0.4 0 0.4 0.4 329 5 327 305 0 0 0 0 1 0 1.5 0.8 10/23/2004 21:30:00 10.8 0.9 13.3 8.4 10.9 0.9 13.3 8.4 0.4 0 0.4 0.4 325 5 312 305 0 0 0 0 0.9 0 1.3 0.8 10/23/2004 21:40:00 10.4 0.9 12.6 8 10.5 1 13.3 8 0.4 0 0.4 0.4 327 5 326 305 0 0 0 0 0.9 0 1.3 0.8 10/23/2004 21:50:00 10.5 0.9 12.6 8.4 10.7 1 13.3 8.4 0.4 0 0.4 0.4 325 5 325 305 0 0 0 0 1 0 1.5 0.8 10/23/2004 22:00:00 10.8 1 13 7.6 10.9 1.1 14.1 8.4 0.4 0 0.4 0.4 330 4 325 305 0 0 0 0 1 0 1.3 1 10/23/2004 22:10:00 11.1 0.8 13.7 9.1 11.3 1 14.1 9.5 0.4 0 0.4 0.4 329 6 327 305 0 0 0 0 1 0 1.3 1 10/23/2004 22:20:00 11.2 0.9 13 8.4 11.5 1 13.3 9.1 0.4 0 0.4 0.4 329 4 329 305 0 0 0 0 1.2 0 1.3 1 10/23/2004 22:30:00 11.6 0.8 13.3 9.5 11.7 0.8 13.7 9.5 0.4 0 0.4 0.4 326 5 330 305 0 0 0 0 1.2 0 1.5 1 10/23/2004 22:40:00 11.1 1 14.1 8 11 1.2 14.1 8 0.4 0 0.4 0.4 322 6 315 305 0 0 0 0 1.3 0 1.3 1.3 10/23/2004 22:50:00 11.3 1.1 13.7 8 11.3 1.2 14.1 8 0.4 0 0.4 0.4 319 6 321 305 0 0 0 0 1.3 0 1.7 1.3 10/23/2004 23:00:00 12 1 14.1 8.8 12 1.2 14.1 8.4 0.4 0 0.4 0.4 322 6 319 305 0 0 0 0 1.3 0 2 1.3 10/23/2004 23:10:00 12.5 1 14.9 9.1 12.5 1.1 14.9 8.8 0.4 0 0.4 0.4 325 6 323 305 0 0 0 0 1.4 0 2 1.3 10/23/2004 23:20:00 12.2 0.8 14.1 9.5 12.2 0.9 14.1 9.1 0.4 0 0.4 0.4 329 5 324 305 0 0 0 0 1.4 0 1.7 1.3 10/23/2004 23:30:00 11.9 1 14.1 9.1 12 1 14.5 9.5 0.4 0 0.4 0.4 332 4 332 305 0 0 0 0 1.4 0 2 1.3 10/23/2004 23:40:00 12.2 1.1 14.9 8.8 12.3 1.1 14.9 8.8 0.4 0 0.4 0.4 327 5 324 305 0 0 0 0 1.4 0 2 1.3 10/23/2004 23:50:00 12.1 1.2 16.1 9.1 12.2 1.3 15.6 9.5 0.4 0 0.4 0.4 327 6 323 305 0 0 0 0 1.4 0 2 1.3 10/24/2004 00:00:00 12.9 1.3 15.6 9.5 13.1 1.3 16.4 9.5 0.4 0 0.4 0.4 327 5 324 305 0 0 0 0 1.4 0 2 1.3 10/24/2004 00:10:00 12.7 1.4 16.1 9.5 12.8 1.5 16.4 9.5 0.4 0 0.4 0.4 329 5 323 305 0 0 0 0 1.4 0 1.7 1.3 10/24/2004 00:20:00 12.5 1 15.3 9.9 12.7 1.1 14.9 9.9 0.4 0 0.4 0.4 331 6 329 305 0 0 0 0 1.6 0 2 1.5 10/24/2004 00:30:00 12.2 1 14.5 9.5 12.4 1.1 14.9 9.1 0.4 0 0.4 0.4 331 6 331 305 0 0 0 0 1.6 0 2 1.5 10/24/2004 00:40:00 12.4 1 14.9 9.1 12.6 1 14.5 9.1 0.4 0 0.4 0.4 332 5 327 305 0 0 0 0 1.5 0 2 1.3 10/24/2004 00:50:00 12.2 1.2 14.9 9.1 12.2 1.3 15.3 8.8 0.4 0 0.4 0.4 331 4 329 305 0 0 0 0 1.5 0 2 1.5 10/24/2004 01:00:00 13 1 14.9 10.3 13.2 1.2 15.6 9.9 0.4 0 0.4 0.4 334 4 332 305 0 0 0 0 1.4 0 2 1.3 10/24/2004 01:10:00 12.6 1.1 15.3 9.9 12.7 1.1 14.9 8.8 0.4 0 0.4 0.4 330 5 329 305 0 0 0 0 1.5 0 2 1.3 10/24/2004 01:20:00 12.4 1 14.9 9.5 12.5 1 14.5 9.9 0.4 0 0.4 0.4 330 4 328 305 0 0 0 0 1.4 0 2 1.3 10/24/2004 01:30:00 12.9 1 15.3 10.3 13 1 15.6 9.5 0.4 0 0.4 0.4 327 5 332 305 0 0 0 0 1.4 0 2 1.3 10/24/2004 01:40:00 12.7 1.1 15.3 9.9 12.8 1.2 15.6 9.9 0.4 0 0.4 0.4 331 4 334 305 0 0 0 0 1.4 0 2 1.3 10/24/2004 01:50:00 12.3 1.1 15.3 9.5 12.4 1.2 16.1 9.5 0.4 0 0.4 0.4 332 4 334 305 0 0 0 0 1.5 0 2 1.3 10/24/2004 02:00:00 11.8 0.8 13.7 8.8 11.8 1 14.1 9.1 0.4 0 0.4 0.4 319 9 321 305 0 0 0 0 1.5 0 2 1.3 10/24/2004 02:10:00 12 1 14.5 9.5 12 1.1 14.5 8.8 0.4 0 0.4 0.4 319 5 321 305 0 0 0 0 1.4 0 2 1.3 10/24/2004 02:20:00 11.5 1 14.1 9.1 11.5 1 14.1 8.4 0.4 0 0.4 0.4 325 7 316 305 0 0 0 0 1.4 0 2 1.3 10/24/2004 02:30:00 10.7 1.2 13.3 7.6 10.6 1.4 13.3 7.6 0.4 0 0.4 0.4 324 8 312 305 0 0 0 0 1.4 0 2 1.3 10/24/2004 02:40:00 10.8 0.8 13.3 8.4 10.8 0.9 13.7 8.4 0.4 0 0.4 0.4 321 6 307 305 0 0 0 0 1.3 0 1.7 1.3 10/24/2004 02:50:00 11.5 1 14.5 9.5 11.6 1.1 14.9 9.1 0.4 0 0.4 0.4 328 5 331 305 0 0 0 0 1.3 0 1.7 1.3 10/24/2004 03:00:00 11.2 0.7 13.3 9.5 11.3 0.8 13.3 9.1 0.4 0 0.4 0.4 325 5 315 305 0 0 0 0 1.3 0 2 1.3 10/24/2004 03:10:00 10.6 0.7 12.2 8.4 10.5 0.8 12.2 8 0.4 0 0.4 0.4 310 16 310 305 0 0 0 0 1.2 0.1 1.5 1 10/24/2004 03:20:00 10.9 1 12.6 8 10.7 1.1 12.6 7.6 0.4 0 0.4 0.4 307 12 301 305 0 0 0 0 1 0 1.5 1 10/24/2004 03:30:00 11 1 13 7.6 10.8 1.1 13 7.6 0.4 0 0.4 0.4 307 6 305 305 0 0 0 0 1 0 1.5 0.8 10/24/2004 03:40:00 9.6 1 12.2 6.8 9.3 1.1 11.8 6.8 0.4 0 0.4 0.4 310 13 317 305 0 0 0 0 0.9 0 1.5 0.8 10/24/2004 03:50:00 10.2 0.8 13 8.4 9.9 0.9 12.6 7.6 0.4 0 0.4 0.4 307 12 303 305 0 0 0 0 1 0 1.5 0.8 10/24/2004 04:00:00 10.2 0.9 12.2 7.2 10 1 12.2 6.8 0.4 0 0.4 0.4 306 12 302 305 0 0 0 0 0.9 0.1 1.3 0.6 10/24/2004 04:10:00 11.1 1 13 8 10.8 1.1 13.3 8 0.4 0 0.4 0.4 303 13 3 305 0 0 0 0 0.6 0 1 0.6 10/24/2004 04:20:00 10.9 0.8 12.6 8.8 10.5 1 12.6 7.6 0.4 0 0.4 0.4 303 17 295 305 0 0 0 0 0.5 0 0.6 0.3 10/24/2004 04:30:00 11.6 1 13.7 8.8 11.3 1.1 13.7 8.4 0.4 0 0.4 0.4 307 9 303 305 0 0 0 0 0.5 0 0.6 0.3 10/24/2004 04:40:00 11.6 0.7 13 9.1 11.4 0.9 13.3 8.4 0.4 0 0.4 0.4 304 12 303 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 04:50:00 11.4 0.8 13.3 8.4 11.1 1 13.7 8.4 0.4 0 0.4 0.4 302 17 303 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 05:00:00 12.8 0.6 14.5 11.1 12.5 0.8 13.7 9.1 0.4 0 0.4 0.4 302 12 303 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 05:10:00 11.9 1.2 14.1 8.8 11.5 1.2 14.1 8.8 0.4 0 0.4 0.4 302 17 303 305 0 0 0 0 0.5 0 0.8 0.3 10/24/2004 05:20:00 12.4 0.7 14.1 10.3 12.2 0.8 14.5 9.9 0.4 0 0.4 0.4 301 6 293 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 05:30:00 12.7 0.7 14.1 10.3 12.5 0.9 14.1 9.1 0.4 0 0.4 0.4 302 17 303 305 0 0 0 0 0.4 0 0.6 0.3 10/24/2004 05:40:00 11.5 1 14.1 8.4 11.1 1.1 13.3 8.4 0.4 0 0.4 0.4 304 13 305 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 05:50:00 12 1 14.1 9.1 11.8 1.1 13.7 8.8 0.4 0 0.4 0.4 305 15 303 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 06:00:00 12.5 1 14.1 9.5 12.2 1 14.1 9.1 0.4 0 0.4 0.4 302 14 300 305 0 0 0 0 0.5 0 0.8 0.3 10/24/2004 06:10:00 11.9 0.7 13.7 9.5 11.5 1 13.7 8.8 0.4 0 0.4 0.4 304 15 293 305 0 0 0 0 0.4 0 0.6 0.3 10/24/2004 06:20:00 11.6 0.8 13.3 8.4 11.4 0.9 13.3 8.8 0.4 0 0.4 0.4 305 8 303 305 0 0 0 0 0.5 0 0.8 0.3 10/24/2004 06:30:00 11.6 1.1 14.1 8.4 11.2 1.1 14.1 8 0.4 0 0.4 0.4 300 12 302 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 06:40:00 11.7 1.1 13.7 8.4 11.4 1.2 13.3 8 0.4 0 0.4 0.4 302 21 297 305 0 0 0 0 0.5 0 0.8 0.3 10/24/2004 06:50:00 11.7 1 13.7 8.8 11.3 1 13.3 8 0.4 0 0.4 0.4 303 14 304 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 07:00:00 11.7 1 13.7 8.8 11.4 1.1 13.3 8.4 0.4 0 0.4 0.4 300 12 300 305 0 0 0 0 0.4 0 0.6 0.3 10/24/2004 07:10:00 11.5 0.9 14.1 9.1 11.1 1 13.3 8.4 0.4 0 0.4 0.4 301 20 303 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 07:20:00 11.8 1 14.1 8.8 11.5 1 14.1 8.8 0.4 0 0.4 0.4 302 10 7 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 07:30:00 11.9 0.8 13.3 9.1 11.6 0.9 13.3 9.1 0.4 0 0.4 0.4 302 15 303 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 07:40:00 11.9 1 14.1 9.5 11.5 1 13.7 8.8 0.4 0 0.4 0.4 300 9 294 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 07:50:00 12.3 1 13.7 8.4 12 1 13.7 7.6 0.4 0 0.4 0.4 300 6 294 305 0 0 0 0 0.4 0 1 0.3 10/24/2004 08:00:00 12.4 1 14.1 9.5 12.2 1.2 14.5 9.5 0.4 0 0.4 0.4 299 6 303 305 0 0 0 0 0.4 0 0.6 0.3 10/24/2004 08:10:00 11.8 1 13.7 8.4 11.3 1.2 14.1 8 0.4 0 0.4 0.4 303 20 302 305 0 0 0 0 0.4 0 1 0.3 10/24/2004 08:20:00 12.3 1.1 14.1 8.4 11.9 1.2 14.1 8 0.4 0 0.4 0.4 301 10 305 305 0 0 0 0 0.4 0 0.6 0.3 10/24/2004 08:30:00 12 1.3 14.5 8 11.7 1.5 14.5 7.2 0.4 0 0.4 0.4 297 12 305 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 08:40:00 12 1.3 14.5 9.1 11.5 1.4 14.5 7.2 0.4 0 0.4 0.4 295 6 297 305 0 0 0 0 0.5 0 0.6 0.3 10/24/2004 08:50:00 12.5 1.2 15.3 9.1 11.9 1.3 15.3 8 0.4 0 0.4 0.4 296 6 312 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 09:00:00 12.7 1.3 15.3 8.8 12.2 1.4 15.3 8.8 0.4 0 0.4 0.4 294 6 294 305 0 0 0 0 0.5 0 1 0.6 10/24/2004 09:10:00 12.3 1.1 14.1 8.4 11.8 1.2 14.1 7.2 0.4 0 0.4 0.4 296 5 294 305 0 0 0 0 0.5 0 1 0.6 10/24/2004 09:20:00 11.4 1.3 14.1 7.6 10.9 1.3 14.1 7.6 0.4 0 0.4 0.4 292 9 288 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 09:30:00 11.4 1.2 14.5 7.6 10.9 1.3 13.7 8 0.4 0 0.4 0.4 293 6 297 305 0 0 0 0 0.3 0 0.6 0.1 10/24/2004 09:40:00 11.8 1 13.7 8.8 11.3 1.2 13.7 7.6 0.4 0 0.4 0.4 293 8 298 305 0 0 0 0 0.2 0 0.6 0.1 10/24/2004 09:50:00 10.9 1.3 13.7 7.6 10.6 1.3 14.1 7.6 0.4 0 0.4 0.4 296 8 298 305 0 0 0 0 0.2 0 0.6 0.1 10/24/2004 10:00:00 11.1 1.1 13.7 8 10.9 1.2 14.1 7.6 0.4 0 0.4 0.4 299 6 301 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 10:10:00 10.9 1.1 14.9 8.4 10.6 1.2 14.9 7.6 0.4 0 0.4 0.4 299 8 291 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 10:20:00 10.7 1.3 13.7 8 10.4 1.4 13.3 7.2 0.4 0 0.4 0.4 297 13 299 305 0 0 0 0 0.5 0 0.8 0.3 10/24/2004 10:30:00 11.6 0.8 13.7 8.8 11.3 1 13.7 8.8 0.4 0 0.4 0.4 301 14 294 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 10:40:00 10.7 1 13 7.6 10.4 0.9 12.6 7.6 0.4 0 0.4 0.4 301 13 297 305 0 0 0 0 0.5 0 1 0.6 10/24/2004 10:50:00 10.6 1.2 13 7.2 10.2 1.3 12.6 6.5 0.4 0 0.4 0.4 296 5 298 305 0 0 0 0 0.5 0 1 0.6 10/24/2004 11:00:00 11 1.1 13.3 8.4 10.5 1.1 12.6 7.2 0.4 0 0.4 0.4 295 9 288 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 11:10:00 10.5 0.8 12.2 8.8 10.2 0.9 11.8 8 0.4 0 0.4 0.4 303 6 305 305 0 0 0 0 0.5 0 0.8 0.3 10/24/2004 11:20:00 10.4 0.9 12.2 7.6 10.2 1 11.8 7.6 0.4 0 0.4 0.4 300 12 303 305 0 0 0 0 0.5 0 1 0.6 10/24/2004 11:30:00 9.8 1 12.2 7.6 9.4 1 12.2 7.2 0.4 0 0.4 0.4 294 6 290 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 11:40:00 9.4 0.8 11.1 6.8 9 1 11.1 6.8 0.4 0 0.4 0.4 294 10 297 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 11:50:00 9.4 1.2 12.6 6.8 8.9 1.2 12.6 6.5 0.4 0 0.4 0.4 289 7 287 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 12:00:00 10.1 1.2 13 7.2 9.5 1.3 12.2 5.7 0.4 0 0.4 0.4 288 7 290 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 12:10:00 9.7 1.2 12.2 6.8 9.4 1.3 12.2 6.8 0.4 0 0.4 0.4 292 6 300 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 12:20:00 9.2 0.9 11.5 6.5 8.9 1 11.5 5.3 0.4 0 0.4 0.4 297 10 279 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 12:30:00 10 0.7 11.8 7.6 9.6 0.9 11.8 6.8 0.4 0 0.4 0.4 293 5 299 305 0 0 0 0 0.5 0 1 0.6 10/24/2004 12:40:00 9.7 0.8 12.2 7.6 9.2 0.9 11.8 6.5 0.4 0 0.4 0.4 293 5 298 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 12:50:00 10.7 0.9 12.2 7.6 9.8 1.1 12.2 6.8 0.4 0 0.4 0.4 284 9 291 305 0 0 0 0 0.4 0 1 0.3 10/24/2004 13:00:00 10.5 1.1 13 6.8 9.9 1.3 12.2 6.1 0.4 0 0.4 0.4 287 12 283 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 13:10:00 9.9 1.1 12.2 7.2 9.3 1.3 12.2 5.7 0.4 0 0.4 0.4 287 7 293 305 0 0 0 0 0.4 0 1 0.3 10/24/2004 13:20:00 10.3 0.9 12.2 7.2 9.7 1 11.8 7.2 0.4 0 0.4 0.4 288 6 288 305 0 0 0 0 0.4 0 1 0.3 10/24/2004 13:30:00 9.9 1.1 11.8 6.8 9.2 1.3 11.8 5.3 0.4 0 0.4 0.4 288 12 287 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 13:40:00 9.5 1.2 11.8 6.5 8.8 1.2 11.5 6.1 0.4 0 0.4 0.4 286 7 282 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 13:50:00 9.3 0.9 11.5 5.7 8.8 1 10.7 5.3 0.4 0 0.4 0.4 289 7 287 305 0 0 0 0 0.5 0 1 0.6 10/24/2004 14:00:00 9 1 11.1 6.5 8.4 1.2 11.1 4.9 0.4 0 0.4 0.4 287 9 288 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 14:10:00 9.5 1.1 11.5 5.7 9 1.2 11.5 4.9 0.4 0 0.4 0.4 290 8 291 305 0 0 0 0 0.4 0 0.6 0.1 10/24/2004 14:20:00 9.3 0.8 11.5 6.8 8.8 1 10.7 6.1 0.4 0 0.4 0.4 291 8 280 305 0 0 0 0 0.3 0 0.6 0.1 10/24/2004 14:30:00 9.4 0.7 11.1 6.5 9 0.8 10.7 6.5 0.4 0 0.4 0.4 292 5 292 305 0 0 0 0 0.4 0 0.6 0.3 10/24/2004 14:40:00 9.3 0.9 11.1 6.1 9 1 11.5 5.7 0.4 0 0.4 0.4 292 6 293 305 0 0 0 0 0.3 0 0.8 0.1 10/24/2004 14:50:00 9.4 0.7 11.1 6.8 8.7 0.9 10.7 5.3 0.4 0 0.4 0.4 286 6 289 305 0 0 0 0 0.2 0 0.6 0.1 10/24/2004 15:00:00 8.5 1 11.1 6.1 7.8 1 10.3 5.3 0.4 0 0.4 0.4 287 8 280 305 0 0 0 0 0.3 0 0.6 0.1 10/24/2004 15:10:00 8.3 0.9 9.9 6.1 7.8 0.9 9.9 5.7 0.4 0 0.4 0.4 287 7 285 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 15:20:00 8.1 1 10.3 5.3 7.6 1 10.3 4.9 0.4 0 0.4 0.4 291 6 302 305 0 0 0 0 0.5 0 1 0.3 10/24/2004 15:30:00 8.1 0.7 9.9 6.1 7.8 0.8 9.5 5.3 0.4 0 0.4 0.4 293 6 296 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 15:40:00 7.9 0.7 9.9 5.3 7.6 0.9 9.9 4.9 0.4 0 0.4 0.4 291 6 282 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 15:50:00 7.7 0.7 9.5 5.7 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 291 6 277 305 0 0 0 0 0.4 0 1 0.3 10/24/2004 16:00:00 8.1 0.6 9.5 6.1 7.4 0.8 9.1 5.3 0.4 0 0.4 0.4 284 5 287 305 0 0 0 0 0.4 0 0.6 0.3 10/24/2004 16:10:00 7.8 0.6 9.1 5.3 7.1 0.8 8.8 4.6 0.4 0 0.4 0.4 283 6 288 305 0 0 0 0 0.3 0 0.6 0.3 10/24/2004 16:20:00 7.3 0.6 8.8 4.9 6.6 0.9 8.8 4.2 0.4 0 0.4 0.4 284 6 281 305 0 0 0 0 0.3 0 0.8 0.1 10/24/2004 16:30:00 6.5 0.9 8.8 3.8 5.8 1 8.8 3.4 0.4 0 0.4 0.4 280 8 278 305 0 0 0 0 0.4 0 1 0.3 10/24/2004 16:40:00 6.7 0.8 8.4 4.6 6.4 0.8 8.4 4.6 0.4 0 0.4 0.4 293 10 292 305 0 0 0 0 0.4 0 0.8 0.3 10/24/2004 16:50:00 6.9 0.6 8.8 4.9 6.8 0.7 8 4.9 0.4 0 0.4 0.4 300 17 303 305 0 0 0 0 0.4 0 0.8 0.1 10/24/2004 17:00:00 6.5 0.6 7.6 4.6 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 300 11 298 305 0 0 0 0 0.3 0 0.6 0.1 10/24/2004 17:10:00 6.4 0.5 8 4.6 6.1 0.5 7.6 4.6 0.4 0 0.4 0.4 288 6 288 305 0 0 0 0 0.2 0 0.6 0.1 10/24/2004 17:20:00 5.9 0.7 7.2 3.4 5.5 0.9 6.8 3 0.4 0 0.4 0.4 282 5 279 305 0 0 0 0 0.2 0 0.6 0.1 10/24/2004 17:30:00 6 0.7 7.2 3.8 5.4 0.7 6.8 3.4 0.4 0 0.4 0.4 280 5 279 305 0 0 0 0 0.2 0 0.6 0.1 10/24/2004 17:40:00 6.1 0.8 7.6 3.4 5.5 1 7.6 3 0.4 0 0.4 0.4 284 8 285 305 0 0 0 0 0.2 0 0.6 0.1 10/24/2004 17:50:00 5.6 0.6 6.8 3.8 5.2 0.5 6.5 3.8 0.4 0 0.4 0.4 285 6 283 305 0 0 0 0 0.2 0.1 0.6 0.1 10/24/2004 18:00:00 5.4 0.5 6.8 4.2 5 0.7 6.8 3.4 0.4 0 0.4 0.4 283 5 288 305 0 0 0 0 0.1 0.1 0.6 0.1 10/24/2004 18:10:00 5.7 0.7 7.2 3.8 5.2 0.8 6.8 3.4 0.4 0 0.4 0.4 282 6 285 305 0 0 0 0 0.1 0.1 0.6 0.1 10/24/2004 18:20:00 4.8 0.8 6.5 2.6 4 0.8 6.1 2.3 0.4 0 0.4 0.4 277 7 276 305 0 0 0 0 0 0 0.6 0.1 10/24/2004 18:30:00 5.1 0.5 6.1 3.4 4.4 0.7 6.1 2.6 0.4 0 0.4 0.4 280 8 282 305 0 0 0 0 0 0 0.6 0.1 10/24/2004 18:40:00 4.7 0.6 6.5 2.6 3.8 0.7 5.3 1.9 0.4 0 0.4 0.4 271 8 279 305 0 0 0 0 0 0.1 0.6 0.1 10/24/2004 18:50:00 5.8 0.7 7.2 3.8 4.7 0.6 6.8 3 0.4 0 0.4 0.4 270 7 275 305 0 0 0 0 0 0 0.3 0.1 10/24/2004 19:00:00 5.7 0.7 7.6 3.8 4.5 0.7 6.5 2.6 0.4 0 0.4 0.4 269 6 246 305 0 0 0 0 0 0 0.3 -0.1 10/24/2004 19:10:00 5.7 0.7 7.2 3.4 4.4 0.7 6.1 2.3 0.4 0 0.4 0.4 268 6 270 305 0 0 0 0 -0.1 0 0.1 -0.4 10/24/2004 19:20:00 5.1 0.7 6.5 3.4 4.1 0.6 5.7 2.3 0.4 0 0.4 0.4 272 6 272 305 0 0 0 0 -0.3 0 0.1 -0.4 10/24/2004 19:30:00 4.2 0.5 5.7 3 3.4 0.5 5.3 1.9 0.4 0 0.4 0.4 263 5 266 305 0 0 0 0 -0.4 0 0.1 -0.6 10/24/2004 19:40:00 4 0.5 5.3 2.6 3.2 0.4 4.2 1.9 0.4 0 0.4 0.4 270 7 274 305 0 0 0 0 -0.4 0 -0.4 -0.6 10/24/2004 19:50:00 3.7 0.5 4.9 2.3 3.2 0.5 4.6 1.5 0.4 0 0.4 0.4 260 6 264 305 0 0 0 0 -0.5 0 -0.1 -0.6 10/24/2004 20:00:00 3.1 0.6 4.6 1.5 2.5 0.6 4.2 1.1 0.4 0 0.4 0.4 266 8 261 305 0 0 0 0 -0.5 0 -0.4 -0.6 10/24/2004 20:10:00 1.9 0.7 3.4 0.4 1.7 0.6 3.8 0.4 0.4 0 0.4 0.4 256 13 262 305 0 0 0 0 -0.6 0 -0.1 -0.6 10/24/2004 20:20:00 1.7 0.6 3 0.4 1.6 0.7 3 0.4 0.4 0 0.4 0.4 246 27 247 305 0 0 0 0 -0.6 0 0.1 -0.6 10/24/2004 20:30:00 3.1 0.8 5.3 0.7 2.6 0.7 4.2 0.7 0.4 0 0.4 0.4 271 13 247 305 0 0 0 0 -0.5 0.1 0.1 -0.6 10/24/2004 20:40:00 2.8 0.8 4.6 0.4 2.5 0.9 4.9 0.7 0.4 0 0.4 0.4 262 11 255 305 0 0 0 0 -0.4 0.1 0.1 -0.4 10/24/2004 20:50:00 3.1 0.6 4.2 1.9 2.8 0.7 4.6 1.1 0.4 0 0.4 0.4 286 8 294 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/24/2004 21:00:00 3.1 0.3 3.8 2.3 3 0.3 3.8 2.3 0.4 0 0.4 0.4 290 6 294 305 0 0 0 0 -0.5 0 -0.1 -0.6 10/24/2004 21:10:00 3.1 0.4 4.6 2.3 3 0.4 4.2 2.3 0.4 0 0.4 0.4 291 6 301 305 0 0 0 0 -0.5 0 0.1 -0.6 10/24/2004 21:20:00 3.4 0.3 4.2 2.3 3.2 0.4 3.8 1.9 0.4 0 0.4 0.4 282 5 297 305 0 0 0 0 -0.5 0 0.1 -0.6 10/24/2004 21:30:00 3.3 0.4 4.2 2.6 3 0.5 3.8 1.9 0.4 0 0.4 0.4 278 3 279 305 0 0 0 0 -0.6 0 -0.1 -0.6 10/24/2004 21:40:00 2.5 0.4 3.4 1.5 2 0.5 3.4 0.7 0.4 0 0.4 0.4 264 6 262 305 0 0 0 0 -0.5 0 0.1 -0.6 10/24/2004 21:50:00 2.4 0.4 3.4 1.1 2.3 0.5 3.4 0.7 0.4 0 0.4 0.4 252 8 250 305 0 0 0 0 -0.6 0 -0.1 -0.6 10/24/2004 22:00:00 1.5 0.5 2.6 0.7 1.8 0.4 2.6 1.1 0.4 0 0.4 0.4 239 6 249 305 0 0 0 0 -0.7 0 -0.4 -0.6 10/24/2004 22:10:00 0.4 0.2 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 233 0 232 305 0 0 0 0 -0.7 0 -0.4 -0.8 10/24/2004 22:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 275 26 305 305 0 0 0 0 -0.8 0 -0.4 -0.8 10/24/2004 22:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 303 8 305 305 0 0 0 0 -0.7 0 -0.1 -0.8 10/24/2004 22:40:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 277 33 305 305 0 0 0 0 -0.8 0.1 -0.4 -1.1 10/24/2004 22:50:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 255 27 305 305 0 0 0 0 -1.1 0.1 -0.6 -1.1 10/24/2004 23:00:00 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 207 26 186 305 0 0 0 0 -1.1 0.1 -0.4 -1.1 10/24/2004 23:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 222 18 305 305 0 0 0 0 -1.1 0 -0.6 -1.1 10/24/2004 23:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 224 12 305 305 0 0 0 0 -1.3 0.1 -0.8 -1.8 10/24/2004 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 206 0 305 305 0 0 0 0 -1.5 0 -1.1 -1.5 10/24/2004 23:40:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 203 1 305 305 0 0 0 0 -1.2 0 -0.6 -1.5 10/24/2004 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 0 0 0 0 -1 0.1 -0.6 -1.1 10/25/2004 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 0 0 0 0 -1.1 0 -0.6 -1.1 10/25/2004 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 0 0 0 0 -1.1 0 -0.6 -1.1 10/25/2004 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 0 0 0 0 -1.1 0 -0.6 -1.1 10/25/2004 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 0 0 0 0 -1.1 0 -0.6 -1.3 10/25/2004 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 0 0 0 0 -1.1 0 -0.6 -1.1 10/25/2004 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 0 0 0 0 -1 0 -0.6 -1.1 10/25/2004 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 0 0 0 0 -0.8 0 -0.6 -1.1 10/25/2004 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 0 0 0 0 -0.9 0 -0.6 -1.1 10/25/2004 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 0 0 0 0 -0.9 0 -0.6 -1.1 10/25/2004 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 0 0 0 0 -1 0 -0.6 -1.1 10/25/2004 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 0 0 0 0 -0.8 0 -0.6 -1.1 10/25/2004 01:50:00 0.4 0 0.4 0.4 0.8 0.5 1.5 0.4 0.4 0 0.4 0.4 168 22 305 305 0 0 0 0 -0.8 0 -0.6 -1.1 10/25/2004 02:00:00 0.4 0.3 1.9 0.4 1 0.3 1.9 0.4 0.4 0 0.4 0.4 100 8 82 305 0 0 0 0 -0.8 0 -0.6 -0.8 10/25/2004 02:10:00 1.3 0.8 3 0.4 1.6 0.7 3 0.4 0.4 0 0.4 0.4 85 6 88 305 0 0 0 0 -0.7 0 -0.4 -0.8 10/25/2004 02:20:00 2.3 0.6 3.4 0.7 2.4 0.5 3.4 1.5 0.4 0 0.4 0.4 86 8 75 305 0 0 0 0 -0.3 0 0.1 -0.4 10/25/2004 02:30:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.5 0.4 0 0.4 0.4 81 5 82 305 0 0 0 0 -0.1 0 0.1 -0.1 10/25/2004 02:40:00 3.7 0.6 5.3 2.3 3.6 0.6 4.9 2.3 0.4 0 0.4 0.4 82 7 72 305 0 0 0 0 -0.1 0 0.1 -0.4 10/25/2004 02:50:00 2.4 0.4 3.4 1.1 2.4 0.5 3.8 1.5 0.4 0 0.4 0.4 106 5 87 305 0 0 0 0 -0.4 0 -0.1 -0.6 10/25/2004 03:00:00 1.1 0.5 1.9 0.4 1.4 0.5 2.3 0.4 0.4 0 0.4 0.4 113 4 108 305 0 0 0 0 -0.5 0 0.1 -0.6 10/25/2004 03:10:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 106 6 305 305 0 0 0 0 -0.4 0.1 0.1 -0.4 10/25/2004 03:20:00 0.4 0 0.4 0.4 0.5 0.3 1.9 0.4 0.4 0 0.4 0.4 105 10 305 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/25/2004 03:30:00 0.7 0.7 3.4 0.4 1 0.5 3.4 0.4 0.4 0 0.4 0.4 67 10 64 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/25/2004 03:40:00 3.3 0.6 4.6 1.5 3.2 0.6 4.6 1.5 0.4 0 0.4 0.4 69 10 63 305 0 0 0 0 0 0.1 0.6 -0.4 10/25/2004 03:50:00 3.9 0.4 5.3 3 3.8 0.5 4.9 3 0.4 0 0.4 0.4 69 6 71 305 0 0 0 0 0.2 0 0.6 0.1 10/25/2004 04:00:00 4.2 0.5 5.7 2.6 4 0.5 5.3 2.6 0.4 0 0.4 0.4 73 6 67 305 0 0 0 0 0.3 0 0.6 0.1 10/25/2004 04:10:00 4.7 0.6 6.1 2.6 4.5 0.6 6.1 2.6 0.4 0 0.4 0.4 69 7 62 305 0 0 0 0 0.3 0 0.6 0.3 10/25/2004 04:20:00 4.9 0.4 6.1 3.8 4.8 0.4 5.7 3.4 0.4 0 0.4 0.4 73 5 70 305 0 0 0 0 0.4 0 0.8 0.3 10/25/2004 04:30:00 4.7 0.7 6.5 3 4.5 0.7 6.1 2.6 0.4 0 0.4 0.4 72 6 70 305 0 0 0 0 0.4 0 0.8 0.3 10/25/2004 04:40:00 5.3 0.6 6.8 3.4 5.1 0.6 6.5 3.8 0.4 0 0.4 0.4 70 5 68 305 0 0 0 0 0.5 0 1 0.3 10/25/2004 04:50:00 5.3 0.4 6.5 4.2 5.2 0.4 6.5 4.2 0.4 0 0.4 0.4 67 5 69 305 0 0 0 0 0.5 0 1 0.6 10/25/2004 05:00:00 5.6 0.6 7.2 4.2 5.5 0.6 6.8 3.4 0.4 0 0.4 0.4 72 6 62 305 0 0 0 0 0.5 0 0.8 0.6 10/25/2004 05:10:00 5.8 0.8 9.5 4.2 5.6 0.8 9.1 4.2 0.4 0 0.4 0.4 72 8 72 305 0 0 0 0 0.7 0 1.3 0.6 10/25/2004 05:20:00 6.1 0.8 8.4 4.6 6 0.9 8.4 4.2 0.4 0 0.4 0.4 78 7 70 305 0 0 0 0 0.9 0 1.3 0.8 10/25/2004 05:30:00 6.2 0.6 8 4.6 6 0.6 7.6 4.2 0.4 0 0.4 0.4 78 6 75 305 0 0 0 0 0.9 0 1.3 0.8 10/25/2004 05:40:00 6.5 0.7 8.4 4.9 6.4 0.8 8.4 4.6 0.4 0 0.4 0.4 77 7 79 305 0 0 0 0 1 0 1.5 1 10/25/2004 05:50:00 6.4 1 8.8 3.8 6.3 1 9.1 3.4 0.4 0 0.4 0.4 77 7 84 305 0 0 0 0 1.1 0 1.5 1 10/25/2004 06:00:00 6.2 1.1 9.5 3.4 6.1 1 9.1 3.4 0.4 0 0.4 0.4 73 10 72 305 0 0 0 0 1.3 0 1.5 1.3 10/25/2004 06:10:00 6.8 1.2 10.3 3.8 6.8 1.1 10.3 4.2 0.4 0 0.4 0.4 73 15 73 305 0 0 0 0 1.4 0 2 1.3 10/25/2004 06:20:00 7.3 1.2 10.7 4.2 7.3 1.2 10.7 4.2 0.4 0 0.4 0.4 73 13 74 305 0 0 0 0 1.5 0 2 1.3 10/25/2004 06:30:00 6.9 1.4 12.2 4.2 7 1.3 11.5 3.8 0.4 0 0.4 0.4 66 12 79 305 0 0 0 0 1.3 0 1.7 1.3 10/25/2004 06:40:00 6.8 1.5 10.3 2.6 6.7 1.5 11.1 1.9 0.4 0 0.4 0.4 73 13 70 305 0 0 0 0 1.4 0 2 1.3 10/25/2004 06:50:00 8.1 1.2 13.3 5.3 7.9 1.2 11.5 4.6 0.4 0 0.4 0.4 75 9 66 305 0 0 0 0 1.4 0 2 1.3 10/25/2004 07:00:00 7.4 1 10.7 4.9 7.3 1 10.7 4.9 0.4 0 0.4 0.4 77 12 76 305 0 0 0 0 1.4 0 1.7 1.3 10/25/2004 07:10:00 9.5 1.6 12.6 4.9 9.2 1.7 12.6 4.6 0.4 0 0.4 0.4 76 8 82 305 0 0 0 0 1.6 0 2.2 1.5 10/25/2004 07:20:00 12.3 1.9 17.2 8.4 12 1.8 16.4 7.6 0.4 0 0.4 0.4 75 7 70 305 0 0 0 0 1.9 0 2.5 1.5 10/25/2004 07:30:00 15.6 1.3 18.3 10.3 15 1.2 18.3 11.1 0.4 0 0.4 0.4 77 7 89 305 0 0 0 0 1.3 0.2 2 1 10/25/2004 07:40:00 14.3 1.3 17.6 10.7 13.7 1.5 17.2 9.5 0.4 0 0.4 0.4 77 7 75 305 0 0 0 0 0.7 0.1 1.3 0.6 10/25/2004 07:50:00 13.2 1.6 18.3 9.1 12.4 1.6 17.9 8.8 0.4 0 0.4 0.4 79 7 82 305 0 0 0 0 0.6 0.1 1.3 0.6 10/25/2004 08:00:00 15.2 1.6 18.3 11.1 14.4 1.7 17.6 9.9 0.4 0 0.4 0.4 83 7 81 305 0 0 0 0 1.5 0.2 2 0.8 10/25/2004 08:10:00 15.8 1.5 19.5 12.2 15.2 1.5 18.7 10.7 0.4 0 0.4 0.4 79 8 85 305 0 0 0 0 1.7 0.1 2.2 1.5 10/25/2004 08:20:00 16.7 1.5 20.2 12.2 16.1 1.5 19.5 11.5 0.4 0 0.4 0.4 75 6 75 305 0 0 0 0 1.6 0 2.2 1.5 10/25/2004 08:30:00 16.1 1.6 20.6 11.8 15.6 1.7 19.5 11.5 0.4 0 0.4 0.4 78 7 77 305 0 0 0 0 1.6 0 2.2 1.5 10/25/2004 08:40:00 16.1 1.5 19.9 11.1 15.5 1.5 19.1 10.7 0.4 0 0.4 0.4 79 7 76 305 0 0 0 0 1.6 0 2.2 1.5 10/25/2004 08:50:00 16 1.6 19.9 11.8 15.5 1.8 19.9 9.1 0.4 0 0.4 0.4 75 7 80 305 0 0 0 0 1.6 0 2.2 1.5 10/25/2004 09:00:00 16.1 1.7 19.9 11.8 15.6 1.8 19.5 10.7 0.4 0 0.4 0.4 76 7 77 305 0 0 0 0 1.6 0 2 1.5 10/25/2004 09:10:00 17.5 1.2 20.2 13.7 17.2 1.3 20.2 13.7 0.4 0 0.4 0.4 71 5 70 305 0 0 0 0 1.5 0 2 1.3 10/25/2004 09:20:00 17.1 1.3 19.9 11.8 16.6 1.4 19.1 11.5 0.4 0 0.4 0.4 70 5 67 305 0 0 0 0 1.4 0 2 1.3 10/25/2004 09:30:00 17.6 1.3 20.2 13 17.1 1.5 20.2 12.2 0.4 0 0.4 0.4 68 4 70 305 0 0 0 0 1.4 0 2 1.3 10/25/2004 09:40:00 17.6 1.3 20.6 13.3 17.3 1.3 20.6 13.3 0.4 0 0.4 0.4 66 4 65 305 0 0 0 0 1.4 0 1.7 1.3 10/25/2004 09:50:00 17.2 1.2 19.9 13.7 16.7 1.3 19.5 13.3 0.4 0 0.4 0.4 66 5 66 305 0 0 0 0 1.3 0 1.7 1.3 10/25/2004 10:00:00 16.9 1.1 19.5 13.3 16.5 1.2 19.5 12.6 0.4 0 0.4 0.4 65 5 70 305 0 0 0 0 1.2 0.1 1.5 1 10/25/2004 10:10:00 17.2 1.2 19.9 13.3 16.8 1.4 19.5 12.6 0.4 0 0.4 0.4 62 4 62 305 0 0 0 0 1.2 0.1 1.5 1 10/25/2004 10:20:00 17 1.6 19.9 13 16.6 1.7 19.9 11.8 0.4 0 0.4 0.4 65 5 64 305 0 0 0 0 1.2 0.1 1.5 1 10/25/2004 10:30:00 17.2 1.3 20.6 13 16.7 1.3 19.5 12.6 0.4 0 0.4 0.4 64 5 61 305 0 0 0 0 1.1 0 1.5 1 10/25/2004 10:40:00 17.8 1.2 20.6 13.3 17.4 1.4 20.2 12.6 0.4 0 0.4 0.4 66 4 62 305 0 0 0 0 1 0 1.3 1 10/25/2004 10:50:00 17.8 1 19.9 14.9 17.3 1.1 19.5 13.7 0.4 0 0.4 0.4 66 3 68 305 0 0 0 0 1 0 1.3 0.8 10/25/2004 11:00:00 16.9 1.3 19.5 13.3 16.5 1.5 19.5 12.2 0.4 0 0.4 0.4 66 5 66 305 0 0 0 0 1 0 1.5 0.8 10/25/2004 11:10:00 16.7 1.1 19.1 13.3 16.3 1.2 19.1 12.6 0.4 0 0.4 0.4 69 5 65 305 0 0 0 0 0.8 0 1.3 0.8 10/25/2004 11:20:00 16.2 1.4 19.1 12.6 15.9 1.5 18.7 12.2 0.4 0 0.4 0.4 67 5 66 305 0 0 0 0 0.9 0 1.3 0.8 10/25/2004 11:30:00 16.7 1.5 19.1 12.2 16.3 1.5 19.5 11.1 0.4 0 0.4 0.4 67 6 70 305 0 0 0 0 0.8 0 1.3 0.6 10/25/2004 11:40:00 16.9 1.4 19.9 13.3 16.5 1.5 19.9 13 0.4 0 0.4 0.4 65 5 66 305 0 0 0 0 0.8 0 1.3 0.6 10/25/2004 11:50:00 18.3 1.3 21 13.3 17.8 1.3 20.6 13.3 0.4 0 0.4 0.4 69 4 65 305 0 0 0 0 0.6 0.1 1.3 0.6 10/25/2004 12:00:00 17.1 1.5 20.6 13 16.7 1.6 20.2 11.8 0.4 0 0.4 0.4 65 6 66 305 0 0 0 0 0.7 0 1.3 0.6 10/25/2004 12:10:00 18.6 1.3 21 14.1 18.1 1.5 21.4 14.5 0.4 0 0.4 0.4 65 5 67 305 0 0 0 0 0.7 0.1 1.3 0.6 10/25/2004 12:20:00 18 1.5 21.4 14.1 17.5 1.5 21 13.7 0.4 0 0.4 0.4 66 5 67 305 0 0 0 0 0.7 0.1 1.3 0.6 10/25/2004 12:30:00 17.5 1.6 21.4 13.7 17 1.7 21 13 0.4 0 0.4 0.4 63 5 52 305 0 0 0 0 0.8 0 1.5 0.6 10/25/2004 12:40:00 18.2 1.3 20.6 14.5 17.6 1.5 20.6 13.7 0.4 0 0.4 0.4 61 5 64 305 0 0 0 0 0.8 0 1.3 0.8 10/25/2004 12:50:00 17.4 1.7 22.1 12.6 16.8 1.7 21.4 12.2 0.4 0 0.4 0.4 63 6 66 305 0 0 0 0 0.9 0 1.3 0.6 10/25/2004 13:00:00 19 1.2 21.4 14.1 18.6 1.5 21.8 12.6 0.4 0 0.4 0.4 61 5 57 305 0 0 0 0 0.8 0 1.3 0.8 10/25/2004 13:10:00 18.6 1.4 22.1 14.1 18.1 1.5 21.8 13 0.4 0 0.4 0.4 61 5 57 305 0 0 0 0 0.8 0 1.3 0.6 10/25/2004 13:20:00 18.4 1.7 21.4 13.3 17.9 1.7 21 12.6 0.4 0 0.4 0.4 61 7 56 305 0 0 0 0 0.7 0 1.3 0.6 10/25/2004 13:30:00 18.4 1.9 23.3 14.1 17.8 2 23.3 13.3 0.4 0 0.4 0.4 64 6 69 305 0 0 0 0 0.8 0.1 1.3 0.6 10/25/2004 13:40:00 18.3 1.8 22.6 13.3 17.8 1.9 22.1 12.2 0.4 0 0.4 0.4 60 6 60 305 0 0 0 0 0.7 0 1.3 0.6 10/25/2004 13:50:00 19.6 1.7 23.3 14.1 18.9 1.7 22.9 14.5 0.4 0 0.4 0.4 56 5 56 305 0 0 0 0 0.7 0 1 0.6 10/25/2004 14:00:00 19.4 1.7 23.3 14.5 18.8 1.7 22.9 14.5 0.4 0 0.4 0.4 58 6 67 305 0 0 0 0 0.7 0 1.3 0.6 10/25/2004 14:10:00 20.1 1.7 23.3 16.1 19.5 1.7 23.3 14.9 0.4 0 0.4 0.4 60 6 59 305 0 0 0 0 0.6 0.1 1 0.6 10/25/2004 14:20:00 19.4 1.7 23.3 14.9 18.9 1.8 22.6 14.1 0.4 0 0.4 0.4 62 5 66 305 0 0 0 0 0.6 0.1 1 0.6 10/25/2004 14:30:00 19.5 1.5 22.6 14.9 18.9 1.5 22.1 14.5 0.4 0 0.4 0.4 61 6 57 305 0 0 0 0 0.6 0.1 1 0.6 10/25/2004 14:40:00 19.3 1.5 22.9 15.3 18.8 1.6 22.6 14.9 0.4 0 0.4 0.4 59 6 55 305 0 0 0 0 0.7 0 1 0.6 10/25/2004 14:50:00 19 1.5 22.1 14.5 18.4 1.6 22.1 13 0.4 0 0.4 0.4 63 5 57 305 0 0 0 0 0.7 0 1 0.6 10/25/2004 15:00:00 19.1 1.7 22.6 13.7 18.6 1.8 22.6 13 0.4 0 0.4 0.4 62 5 60 305 0 0 0 0 0.7 0 1 0.6 10/25/2004 15:10:00 17.8 1.6 22.1 13.3 17.2 1.6 20.2 12.6 0.4 0 0.4 0.4 57 7 52 305 0 0 0 0 0.7 0.1 1.3 0.6 10/25/2004 15:20:00 19.4 1.7 22.9 14.5 18.8 1.7 22.6 14.1 0.4 0 0.4 0.4 56 5 53 305 0 0 0 0 0.7 0.1 1.3 0.6 10/25/2004 15:30:00 19.4 1.7 22.9 14.5 18.9 1.7 23.3 13.7 0.4 0 0.4 0.4 62 5 61 305 0 0 0 0 0.6 0.1 1 0.6 10/25/2004 15:40:00 19.2 1.7 22.9 13.7 18.6 1.7 22.1 13.3 0.4 0 0.4 0.4 55 7 49 305 0 0 0 0 0.7 0 1 0.6 10/25/2004 15:50:00 18.5 1.7 21.8 14.1 17.7 1.8 22.1 13.7 0.4 0 0.4 0.4 53 6 52 305 0 0 0 0 0.8 0.1 1.3 0.6 10/25/2004 16:00:00 18.2 1.9 23.7 13 17.8 2 24 11.8 0.4 0 0.4 0.4 57 6 49 305 0 0 0 0 0.8 0 1 0.6 10/25/2004 16:10:00 19.3 2 22.9 13 18.6 2.1 23.3 12.2 0.4 0 0.4 0.4 51 6 57 305 0 0 0 0 0.8 0.1 1.3 0.6 10/25/2004 16:20:00 19.7 2 23.7 14.9 19.1 2 24 14.5 0.4 0 0.4 0.4 48 5 50 305 0 0 0 0 0.8 0 1.3 0.6 10/25/2004 16:30:00 19.2 1.9 23.3 13.7 18.8 2 22.9 13.7 0.4 0 0.4 0.4 52 7 48 305 0 0 0 0 0.9 0 1.5 0.6 10/25/2004 16:40:00 20.7 1.5 24.4 16.4 20.1 1.7 23.3 14.9 0.4 0 0.4 0.4 52 5 43 305 0 0 0 0 0.8 0 1.3 0.6 10/25/2004 16:50:00 20.4 1.7 24 15.6 19.8 1.9 24 14.9 0.4 0 0.4 0.4 55 5 50 305 0 0 0 0 0.9 0 1.3 0.8 10/25/2004 17:00:00 20.4 2 24.4 15.3 19.8 2.1 24 14.5 0.4 0 0.4 0.4 56 5 58 305 0 0 0 0 0.9 0 1.3 0.8 10/25/2004 17:10:00 19.8 1.7 23.7 15.6 19.3 1.7 23.7 14.9 0.4 0 0.4 0.4 53 5 54 305 0 0 0 0 0.9 0 1.5 0.8 10/25/2004 17:20:00 18.8 1.6 23.7 15.3 18.2 1.7 23.3 14.5 0.4 0 0.4 0.4 53 5 56 305 0 0 0 0 1 0 1.5 0.8 10/25/2004 17:30:00 20.9 1.8 24.8 16.4 20.4 2 24 14.9 0.4 0 0.4 0.4 53 5 57 305 0 0 0 0 0.9 0 1.5 0.6 10/25/2004 17:40:00 20.4 2.6 26.3 13.7 19.9 2.6 25.2 14.1 0.4 0 0.4 0.4 51 5 51 305 0 0 0 0 0.9 0 1.5 0.6 10/25/2004 17:50:00 19.9 1.9 24.4 14.5 19.3 2 23.7 14.1 0.4 0 0.4 0.4 52 5 60 305 0 0 0 0 0.9 0 1.5 0.6 10/25/2004 18:00:00 21 1.8 25.2 15.6 20.5 1.9 25.2 14.1 0.4 0 0.4 0.4 51 6 50 305 0 0 0 0 0.8 0 1.3 0.6 10/25/2004 18:10:00 21.8 1.7 25.6 16.8 21.2 1.9 26 16.1 0.4 0 0.4 0.4 50 6 50 305 0 0 0 0 0.7 0 1 0.6 10/25/2004 18:20:00 21.7 1.9 25.2 15.6 21.1 2.1 25.2 15.6 0.4 0 0.4 0.4 50 5 48 305 0 0 0 0 0.7 0 1 0.6 10/25/2004 18:30:00 21.6 1.7 25.6 17.2 21.2 1.8 26 16.8 0.4 0 0.4 0.4 49 5 43 305 0 0 0 0 0.6 0.1 1 0.6 10/25/2004 18:40:00 22.3 2.1 26.3 15.6 21.7 2.1 26.3 15.6 0.4 0 0.4 0.4 49 5 54 305 0 0 0 0 0.5 0 1 0.6 10/25/2004 18:50:00 21.2 1.7 24.8 16.4 20.6 1.8 24.4 15.6 0.4 0 0.4 0.4 52 5 52 305 0 0 0 0 0.6 0 1 0.6 10/25/2004 19:00:00 22.5 1.7 26.3 17.6 21.7 1.8 26.3 16.8 0.4 0 0.4 0.4 53 5 48 305 0 0 0 0 0.5 0 0.6 0.3 10/25/2004 19:10:00 21.9 1.9 25.6 16.1 21.4 1.9 26 14.9 0.4 0 0.4 0.4 48 6 53 305 0 0 0 0 0.5 0 0.8 0.3 10/25/2004 19:20:00 21.3 2.3 26.8 14.5 20.7 2.4 25.2 14.1 0.4 0 0.4 0.4 44 5 46 305 0 0 0 0 0.5 0 1 0.3 10/25/2004 19:30:00 21.4 1.7 25.2 16.8 20.8 1.8 25.2 16.1 0.4 0 0.4 0.4 43 5 43 305 0 0 0 0 0.4 0 1 0.3 10/25/2004 19:40:00 20.3 2.1 25.2 15.6 19.9 2.2 24.8 15.3 0.4 0 0.4 0.4 51 8 52 305 0 0 0 0 0.5 0 1 0.3 10/25/2004 19:50:00 22.3 2 26.3 16.8 21.8 2.1 26.3 15.6 0.4 0 0.4 0.4 49 5 54 305 0 0 0 0 0.4 0 1 0.1 10/25/2004 20:00:00 21.5 2 25.6 16.4 21.1 2 25.6 15.6 0.4 0 0.4 0.4 49 6 39 305 0 0 0 0 0.4 0 0.6 0.3 10/25/2004 20:10:00 22.2 1.6 26.3 17.2 21.7 1.7 25.6 17.2 0.4 0 0.4 0.4 49 5 51 305 0 0 0 0 0.4 0 0.8 0.3 10/25/2004 20:20:00 21 1.8 25.6 16.4 20.5 1.9 25.2 15.3 0.4 0 0.4 0.4 45 6 46 305 0 0 0 0 0.4 0 0.6 0.3 10/25/2004 20:30:00 22 2.2 26.3 15.3 21.5 2.3 25.6 14.5 0.4 0 0.4 0.4 45 6 38 305 0 0 0 0 0.4 0 1 0.3 10/25/2004 20:40:00 21.1 2.1 26 15.3 20.6 2.2 25.6 15.3 0.4 0 0.4 0.4 42 5 42 305 0 0 0 0 0.4 0 0.6 0.1 10/25/2004 20:50:00 22.3 2 26.8 15.6 21.7 2 26 15.6 0.4 0 0.4 0.4 46 5 46 305 0 0 0 0 0.3 0 0.8 0.1 10/25/2004 21:00:00 23 1.6 26 17.9 22.3 1.7 26 16.8 0.4 0 0.4 0.4 48 6 40 305 0 0 0 0 0.2 0.1 0.6 0.1 10/25/2004 21:10:00 23 1.6 26.8 17.9 22.4 1.7 26.8 17.2 0.4 0 0.4 0.4 50 4 50 305 0 0 0 0 -0.1 0 0.6 -0.4 10/25/2004 21:20:00 23.3 2 27.1 17.6 22.8 2 27.5 17.6 0.4 0 0.4 0.4 45 5 48 305 0 0 0 0 -0.2 0.1 0.3 -0.4 10/25/2004 21:30:00 22.5 1.8 26.3 17.9 21.9 2 26.3 16.1 0.4 0 0.4 0.4 48 5 44 305 0 0 0 0 0 0.1 0.6 -0.4 10/25/2004 21:40:00 22 2.1 25.6 16.4 21.3 2.3 26 15.3 0.4 0 0.4 0.4 49 5 44 305 0 0 0 0 0.2 0.1 0.8 0.1 10/25/2004 21:50:00 22.7 2 26.8 16.8 22.2 2.1 26.8 16.1 0.4 0 0.4 0.4 44 5 42 305 0 0 0 0 -0.3 0.1 0.1 -0.6 10/25/2004 22:00:00 22 2 26 16.4 21.5 2.1 26 16.4 0.4 0 0.4 0.4 42 5 50 305 0 0 0 0 -0.4 0 0.1 -0.6 10/25/2004 22:10:00 22.7 1.9 26 16.8 22 2 26 17.2 0.4 0 0.4 0.4 47 6 51 305 0 0 0 0 -0.1 0 0.3 -0.4 10/25/2004 22:20:00 22.4 2.2 27.1 16.8 21.8 2.4 27.5 15.3 0.4 0 0.4 0.4 43 5 44 305 0 0 0 0 0 0 0.3 -0.4 10/25/2004 22:30:00 24 1.9 27.9 17.2 23.4 1.9 27.9 17.9 0.4 0 0.4 0.4 42 5 37 305 0 0 0 0 -0.5 0.1 0.1 -1.1 10/25/2004 22:40:00 23.2 2 27.1 17.2 22.8 2.2 27.1 17.2 0.4 0 0.4 0.4 42 5 42 305 0 0 0 0 -0.7 0 -0.4 -1.1 10/25/2004 22:50:00 22.4 2.3 27.5 16.1 21.9 2.3 27.5 15.3 0.4 0 0.4 0.4 44 6 41 305 0 0 0 0 -0.5 0 0.1 -0.6 10/25/2004 23:00:00 22.2 2.2 26.3 16.4 21.6 2.4 26.8 16.4 0.4 0 0.4 0.4 46 6 39 305 0 0 0 0 -0.5 0 -0.4 -0.6 10/25/2004 23:10:00 22.9 2 27.1 17.9 22.4 2.2 26.8 16.4 0.4 0 0.4 0.4 44 5 41 305 0 0 0 0 -0.5 0 0.1 -0.6 10/25/2004 23:20:00 22.2 1.8 26.8 16.8 21.7 2 26.3 16.8 0.4 0 0.4 0.4 43 5 44 305 0 0 0 0 -0.8 0 -0.4 -1.1 10/25/2004 23:30:00 21.1 1.8 26.8 16.8 20.7 2 26.8 15.6 0.4 0 0.4 0.4 47 6 47 305 0 0 0 0 -0.7 0 -0.4 -1.1 10/25/2004 23:40:00 20.9 1.9 25.2 16.4 20.4 2 25.6 15.6 0.4 0 0.4 0.4 47 5 47 305 0 0 0 0 -0.7 0.2 -0.1 -1.1 10/25/2004 23:50:00 22.1 1.8 25.2 16.4 21.6 2 25.6 15.6 0.4 0 0.4 0.4 48 5 44 305 0 0 0 0 -1.1 0 -0.6 -1.3 10/26/2004 00:00:00 20.6 1.7 24.8 16.1 20 1.8 24.4 15.6 0.4 0 0.4 0.4 49 5 43 305 0 0 0 0 -1 0.1 -0.6 -1.1 10/26/2004 00:10:00 20.8 2 24.4 15.3 20.3 2.1 24.4 14.9 0.4 0 0.4 0.4 51 6 54 305 0 0 0 0 -1.1 0 -0.6 -1.3 10/26/2004 00:20:00 20.9 1.8 24.4 14.9 20.4 1.9 24.8 15.3 0.4 0 0.4 0.4 50 6 49 305 0 0 0 0 -1.1 0 -0.6 -1.3 10/26/2004 00:30:00 20.8 2.1 25.2 16.1 20.2 2.3 25.2 14.9 0.4 0 0.4 0.4 50 5 43 305 0 0 0 0 -1.2 0 -0.6 -1.3 10/26/2004 00:40:00 20 2 24 15.3 19.4 2.1 24 13.7 0.4 0 0.4 0.4 47 5 46 305 0 0 0 0 -1.1 0 -0.6 -1.3 10/26/2004 00:50:00 22.1 1.8 26.8 17.6 21.6 1.9 27.1 16.1 0.4 0 0.4 0.4 46 5 48 305 0 0 0 0 -1.2 0 -0.6 -1.5 10/26/2004 01:00:00 21.5 1.8 26 15.6 20.9 1.9 24.8 15.3 0.4 0 0.4 0.4 46 6 57 305 0 0 0 0 -1.1 0 -0.6 -1.3 10/26/2004 01:10:00 21.8 1.7 25.6 16.8 21.1 1.8 25.2 16.4 0.4 0 0.4 0.4 44 5 39 305 0 0 0 0 -1.1 0 -0.6 -1.3 10/26/2004 01:20:00 21.5 2.1 26.3 16.4 20.9 2.2 26 14.9 0.4 0 0.4 0.4 48 5 46 305 0 0 0 0 -1.1 0.1 -0.4 -1.3 10/26/2004 01:30:00 21.1 2 25.6 15.3 20.3 2 25.6 14.1 0.4 0 0.4 0.4 47 6 53 305 0 0 0 0 -1 0.1 -0.4 -1.1 10/26/2004 01:40:00 22.8 1.6 26.3 18.7 22.2 1.7 26 17.2 0.4 0 0.4 0.4 47 4 44 305 0 0 0 0 -1.2 0 -0.8 -1.3 10/26/2004 01:50:00 20.9 2.2 26 14.9 20.2 2.3 25.6 14.5 0.4 0 0.4 0.4 47 5 42 305 0 0 0 0 -1.2 0 -0.6 -1.3 10/26/2004 02:00:00 21.3 1.7 25.2 15.3 20.6 1.8 24.8 14.9 0.4 0 0.4 0.4 45 6 47 305 0 0 0 0 -1.1 0 -0.6 -1.1 10/26/2004 02:10:00 21.2 1.5 24.4 16.8 20.4 1.7 24.4 14.5 0.4 0 0.4 0.4 44 5 42 305 0 0 0 0 -1.1 0 -0.6 -1.3 10/26/2004 02:20:00 21.5 2.1 26 15.3 20.7 2.1 25.2 14.9 0.4 0 0.4 0.4 44 5 46 305 0 0 0 0 -1.1 0 -0.6 -1.1 10/26/2004 02:30:00 21.3 2.2 25.6 16.1 20.6 2.3 25.2 15.6 0.4 0 0.4 0.4 44 5 48 305 0 0 0 0 -0.9 0.1 -0.4 -1.1 10/26/2004 02:40:00 20.8 1.9 24.8 14.9 20.2 2 24.8 14.5 0.4 0 0.4 0.4 42 5 37 305 0 0 0 0 -0.9 0 -0.4 -1.1 10/26/2004 02:50:00 20.2 1.6 23.7 16.4 19.7 1.7 23.7 15.6 0.4 0 0.4 0.4 45 6 38 305 0 0 0 0 -0.8 0 -0.4 -1.1 10/26/2004 03:00:00 21.3 2.1 24.8 14.9 20.8 2.2 24.4 13.3 0.4 0 0.4 0.4 44 4 40 305 0 0 0 0 -0.8 0.1 -0.4 -1.1 10/26/2004 03:10:00 20.2 2 23.7 14.1 19.6 2.2 23.7 14.5 0.4 0 0.4 0.4 41 5 40 305 0 0 0 0 -0.8 0.2 -0.4 -1.1 10/26/2004 03:20:00 19.7 1.7 23.3 15.6 19.2 1.8 23.3 15.3 0.4 0 0.4 0.4 42 5 40 305 0 0 0 0 -0.7 0 -0.1 -1.1 10/26/2004 03:30:00 20.3 1.7 25.2 16.1 19.7 1.9 25.2 14.5 0.4 0 0.4 0.4 45 5 40 305 0 0 0 0 -0.7 0 -0.1 -0.8 10/26/2004 03:40:00 20.7 1.7 24 16.4 19.9 1.8 24 15.3 0.4 0 0.4 0.4 44 5 39 305 0 0 0 0 -0.7 0 -0.4 -1.1 10/26/2004 03:50:00 20.1 2 23.3 14.9 19.4 2 23.7 14.9 0.4 0 0.4 0.4 42 5 41 305 0 0 1 0 -0.7 0 0.1 -1.1 10/26/2004 04:00:00 21 1.7 24 16.4 20.4 1.7 24.4 15.6 0.4 0 0.4 0.4 43 5 46 305 1 0 1 0 -0.8 0 -0.4 -0.8 10/26/2004 04:10:00 20.2 1.7 24 16.4 19.7 1.8 24.4 15.3 0.4 0 0.4 0.4 45 5 43 305 1 0 1 0 -0.7 0 -0.4 -0.8 10/26/2004 04:20:00 20.2 1.8 24.4 16.1 19.8 1.9 23.7 15.6 0.4 0 0.4 0.4 46 5 48 305 1 0 1 0 -0.8 0 -0.4 -0.8 10/26/2004 04:30:00 19.6 1.7 22.9 13.3 19.2 1.8 22.6 13.3 0.4 0 0.4 0.4 46 5 43 305 1 0 0 0 -0.8 0.1 -0.4 -1.1 10/26/2004 04:40:00 19.6 1.5 22.1 14.5 19 1.7 22.1 13.7 0.4 0 0.4 0.4 47 4 46 305 1 0 0 0 -0.9 0 -0.4 -1.1 10/26/2004 04:50:00 18.8 1.4 22.6 15.3 18.2 1.5 22.1 13.3 0.4 0 0.4 0.4 47 5 48 305 1 0 0 0 -0.8 0 -0.4 -1.1 10/26/2004 05:00:00 19.2 1.5 22.1 15.3 18.5 1.7 22.1 14.1 0.4 0 0.4 0.4 45 5 42 305 1 0 1 0 -0.8 0 -0.6 -1.1 10/26/2004 05:10:00 19.5 1.3 22.1 14.5 18.9 1.5 22.1 14.5 0.4 0 0.4 0.4 41 4 45 305 1 0 1 0 -0.8 0 -0.6 -1.1 10/26/2004 05:20:00 19.2 1.4 22.6 14.9 18.7 1.5 22.6 14.9 0.4 0 0.4 0.4 43 4 47 305 1 0 1 0 -0.8 0 -0.6 -1.1 10/26/2004 05:30:00 18.5 1.6 21.8 14.1 18 1.7 21.8 13.7 0.4 0 0.4 0.4 44 5 40 305 1 0 1 0 -0.6 0 -0.4 -0.8 10/26/2004 05:40:00 18.3 1.7 21.4 13.3 17.8 1.8 21.4 12.6 0.4 0 0.4 0.4 47 5 48 305 1 0 1 0 -0.5 0 -0.4 -0.8 10/26/2004 05:50:00 18.3 1.7 21.8 14.5 17.7 1.7 21.8 14.1 0.4 0 0.4 0.4 43 5 41 305 1 0 1 0 -0.6 0 -0.6 -0.6 10/26/2004 06:00:00 18.1 1.5 21.4 13.7 17.5 1.7 21 13 0.4 0 0.4 0.4 42 5 42 305 1 0 1 0 -0.6 0 -0.4 -0.6 10/26/2004 06:10:00 17.7 1.6 21.8 14.1 17.3 1.7 21.8 13 0.4 0 0.4 0.4 43 5 52 305 1 0 1 0 -0.5 0 -0.4 -0.6 10/26/2004 06:20:00 18.4 1.1 21 15.3 18.1 1.2 20.2 14.5 0.4 0 0.4 0.4 44 5 46 305 1 0 1 0 -0.5 0 -0.4 -0.6 10/26/2004 06:30:00 18.6 1.6 22.1 14.5 18.2 1.6 22.1 13.7 0.4 0 0.4 0.4 41 5 43 305 1 0 1 0 -0.5 0 -0.4 -0.6 10/26/2004 06:40:00 18.9 1.5 22.6 15.3 18.5 1.6 22.6 14.5 0.4 0 0.4 0.4 41 5 45 305 1 0 0 0 -0.5 0 -0.4 -0.6 10/26/2004 06:50:00 18.7 1.5 21.4 14.5 18.3 1.6 21.4 14.1 0.4 0 0.4 0.4 40 5 36 305 1 0 1 0 -0.5 0 0.1 -0.6 10/26/2004 07:00:00 18.2 1.4 21.8 14.9 17.8 1.5 21.8 13.3 0.4 0 0.4 0.4 40 5 42 305 1 0 1 0 -0.4 0.1 0.1 -0.6 10/26/2004 07:10:00 18.6 1.2 21.8 15.3 18.3 1.2 21.4 15.6 0.4 0 0.4 0.4 38 4 41 305 1 0 1 0 -0.5 0.1 0.1 -0.6 10/26/2004 07:20:00 18.5 1.3 21.8 15.3 18.2 1.5 22.1 14.5 0.4 0 0.4 0.4 41 4 42 305 1 0 1 0 -0.5 0.1 0.1 -0.6 10/26/2004 07:30:00 18.3 1.5 21 13.7 18 1.7 21 13 0.4 0 0.4 0.4 39 4 39 305 1 0 0 0 -0.5 0.1 0.1 -0.6 10/26/2004 07:40:00 17.9 1.3 21 14.5 17.4 1.5 21 12.6 0.4 0 0.4 0.4 40 4 37 305 1 0 1 0 -0.4 0.1 0.1 -0.6 10/26/2004 07:50:00 17.8 1.5 21.4 13.3 17.3 1.7 20.6 13 0.4 0 0.4 0.4 38 5 35 305 1 0 1 0 -0.4 0.1 0.1 -0.4 10/26/2004 08:00:00 19.1 1.5 22.1 14.5 18.6 1.6 22.6 14.1 0.4 0 0.4 0.4 40 4 42 305 1 0 1 0 -0.4 0 0.1 -0.6 10/26/2004 08:10:00 18.2 1.4 21 13.7 17.7 1.5 21 12.6 0.4 0 0.4 0.4 37 4 36 305 1 0 1 0 -0.4 0 0.1 -0.4 10/26/2004 08:20:00 17.8 1.7 21 13 17.4 1.8 21 11.8 0.4 0 0.4 0.4 37 4 39 305 1 0 1 0 -0.4 0 0.1 -0.4 10/26/2004 08:30:00 18.1 1.3 21 14.5 17.6 1.5 21 13.7 0.4 0 0.4 0.4 37 4 38 305 1 0 1 0 -0.4 0 0.1 -0.4 10/26/2004 08:40:00 17.8 1.5 21 13.3 17.3 1.7 21 13.3 0.4 0 0.4 0.4 33 5 35 305 0 0 0 0 -0.4 0 0.1 -0.6 10/26/2004 08:50:00 16.8 1.5 19.9 11.5 16.5 1.6 20.2 11.8 0.4 0 0.4 0.4 34 5 39 305 0 0 0 0 -0.3 0 0.1 -0.4 10/26/2004 09:00:00 17.6 1.6 21 13.7 17.3 1.7 20.2 12.2 0.4 0 0.4 0.4 35 5 33 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/26/2004 09:10:00 17.7 1.2 19.9 14.1 17.2 1.4 19.9 13.3 0.4 0 0.4 0.4 38 4 36 305 0 0 0 0 -0.4 0.1 0.1 -0.6 10/26/2004 09:20:00 18.1 1.3 20.6 14.1 17.7 1.4 20.6 14.1 0.4 0 0.4 0.4 34 5 46 305 0 0 0 0 -0.4 0 -0.4 -0.6 10/26/2004 09:30:00 17.2 1.5 20.2 14.1 16.7 1.5 20.2 13.3 0.4 0 0.4 0.4 35 5 33 305 0 0 0 0 -0.4 0 -0.1 -0.4 10/26/2004 09:40:00 17.7 1.2 21 14.5 17.2 1.3 20.6 13 0.4 0 0.4 0.4 34 4 32 305 0 0 0 0 -0.4 0 -0.4 -0.4 10/26/2004 09:50:00 17.8 1.3 21 13.3 17.5 1.3 20.2 13 0.4 0 0.4 0.4 33 4 38 305 0 0 0 0 -0.4 0 -0.1 -0.4 10/26/2004 10:00:00 17.6 1.5 20.6 13.3 17.3 1.7 20.6 12.6 0.4 0 0.4 0.4 32 3 33 305 0 0 0 0 -0.3 0 0.3 -0.4 10/26/2004 10:10:00 17.9 1.3 20.6 14.1 17.4 1.4 20.2 12.6 0.4 0 0.4 0.4 30 4 30 305 0 0 0 0 -0.3 0.1 0.3 -0.4 10/26/2004 10:20:00 17.6 1.3 20.6 14.5 17.2 1.5 20.2 11.8 0.4 0 0.4 0.4 32 4 30 305 0 0 0 0 -0.3 0 0.3 -0.4 10/26/2004 10:30:00 18.1 1.2 20.6 14.5 17.6 1.3 19.9 12.6 0.4 0 0.4 0.4 30 4 32 305 0 0 1 0 -0.3 0 0.3 -0.4 10/26/2004 10:40:00 17.3 1.3 20.2 13.3 17 1.3 20.2 13.3 0.4 0 0.4 0.4 32 3 37 305 0 0 0 0 -0.2 0 0.3 -0.4 10/26/2004 10:50:00 17.5 1.3 19.9 13.7 17.2 1.3 20.2 13.3 0.4 0 0.4 0.4 30 5 31 305 0 0 0 0 -0.2 0 0.3 -0.4 10/26/2004 11:00:00 17.4 1.3 20.2 14.1 17 1.3 19.9 13.3 0.4 0 0.4 0.4 31 5 28 305 0 0 0 0 -0.1 0 0.1 -0.1 10/26/2004 11:10:00 17.5 1.1 20.2 14.1 17.1 1.2 20.6 13.7 0.4 0 0.4 0.4 33 5 35 305 0 0 0 0 -0.1 0 0.1 -0.1 10/26/2004 11:20:00 16.9 1.5 19.9 13.3 16.4 1.5 19.5 12.6 0.4 0 0.4 0.4 30 4 32 305 0 0 0 0 0 0 0.1 -0.1 10/26/2004 11:30:00 16.9 1.5 19.9 13 16.5 1.6 19.5 13 0.4 0 0.4 0.4 33 5 39 305 0 0 1 0 0 0.1 0.6 0.1 10/26/2004 11:40:00 17.6 1.1 19.9 14.5 17.3 1.2 19.5 13.7 0.4 0 0.4 0.4 30 4 29 305 0 0 0 0 0 0.1 0.6 -0.1 10/26/2004 11:50:00 16.7 1.3 19.9 12.6 16.3 1.4 19.1 13 0.4 0 0.4 0.4 35 5 31 305 0 0 0 0 0.1 0.1 0.6 0.1 10/26/2004 12:00:00 16.7 1.3 19.5 12.6 16.4 1.3 19.5 13 0.4 0 0.4 0.4 34 4 35 305 0 0 0 0 0 0.1 0.6 0.1 10/26/2004 12:10:00 17.4 1.3 19.9 13.3 17 1.3 19.5 11.8 0.4 0 0.4 0.4 32 3 30 305 0 0 0 0 0 0 0.6 -0.4 10/26/2004 12:20:00 16.9 1.3 19.5 13.3 16.5 1.4 19.5 12.6 0.4 0 0.4 0.4 31 4 29 305 0 0 1 0 0 0.1 0.6 -0.1 10/26/2004 12:30:00 16.6 1.3 19.9 13 16.6 1.5 19.9 12.6 0.4 0 0.4 0.4 31 4 30 305 0 0 0 0 0.1 0.1 0.6 0.1 10/26/2004 12:40:00 16.8 1.3 20.2 13.7 16.6 1.3 19.9 13 0.4 0 0.4 0.4 31 4 28 305 0 0 0 0 0.2 0.1 0.6 0.1 10/26/2004 12:50:00 16.5 1.1 19.1 13 16.4 1.3 19.5 12.6 0.4 0 0.4 0.4 32 5 31 305 0 0 1 0 0.2 0 0.6 0.1 10/26/2004 13:00:00 16.4 1.5 19.1 13 16.1 1.5 19.1 12.6 0.4 0 0.4 0.4 31 4 30 305 0 0 0 0 0.2 0 0.8 0.1 10/26/2004 13:10:00 16.3 1.3 18.7 12.6 16 1.4 18.7 12.2 0.4 0 0.4 0.4 34 4 38 305 1 0 0 0 0.3 0 0.8 0.1 10/26/2004 13:20:00 17.6 1.4 20.2 13.3 17.3 1.4 20.2 13 0.4 0 0.4 0.4 34 4 31 305 1 0 1 0 0.4 0.1 1 0.1 10/26/2004 13:30:00 16.9 1.1 19.5 14.1 16.6 1.2 19.5 13.3 0.4 0 0.4 0.4 32 4 31 305 0 0 0 0 0.5 0 1 0.3 10/26/2004 13:40:00 16.1 1.2 18.7 12.6 15.9 1.2 18.3 12.2 0.4 0 0.4 0.4 30 5 30 305 1 0 0 0 0.4 0 1 0.3 10/26/2004 13:50:00 16.8 1.3 19.5 12.6 16.6 1.4 19.5 11.8 0.4 0 0.4 0.4 29 4 27 305 1 0 1 0 0.5 0 0.6 0.3 10/26/2004 14:00:00 17 1.2 19.5 13.3 16.8 1.3 19.5 13.3 0.4 0 0.4 0.4 26 4 24 305 1 0 1 0 0.5 0 0.6 0.3 10/26/2004 14:10:00 17.4 1.1 19.5 13.7 17.1 1.2 19.9 13.3 0.4 0 0.4 0.4 29 4 27 305 1 0 1 0 0.5 0 0.8 0.6 10/26/2004 14:20:00 16.6 1 19.1 13.3 16.4 1.1 19.1 13.7 0.4 0 0.4 0.4 29 4 27 305 1 0 0 0 0.5 0 0.8 0.6 10/26/2004 14:30:00 16.2 1.2 18.7 13 16.1 1.3 19.1 12.6 0.4 0 0.4 0.4 30 4 30 305 1 0 1 0 0.6 0 0.8 0.6 10/26/2004 14:40:00 16.3 1.3 19.1 13.3 16.1 1.5 19.1 12.2 0.4 0 0.4 0.4 26 5 23 305 1 0 1 0 0.6 0 0.8 0.6 10/26/2004 14:50:00 16 1.3 18.7 13 15.8 1.4 18.3 11.8 0.4 0 0.4 0.4 26 4 25 305 1 0 1 0 0.6 0 0.8 0.6 10/26/2004 15:00:00 16.6 1.3 19.5 12.2 16.4 1.4 19.9 12.2 0.4 0 0.4 0.4 24 4 19 305 1 0 1 0 0.6 0 0.8 0.6 10/26/2004 15:10:00 16.7 1.2 19.1 12.6 16.6 1.3 19.1 11.8 0.4 0 0.4 0.4 28 3 26 305 1 0 1 0 0.6 0 0.8 0.6 10/26/2004 15:20:00 16.8 1.1 19.5 13.7 16.6 1.2 19.5 13 0.4 0 0.4 0.4 27 4 27 305 1 0 1 0 0.5 0 0.8 0.6 10/26/2004 15:30:00 16.4 1.4 19.1 13 16.4 1.5 19.9 12.2 0.4 0 0.4 0.4 23 4 27 305 1 0 1 0 0.6 0 1 0.6 10/26/2004 15:40:00 16.2 1.5 18.7 11.5 16.1 1.5 19.1 11.5 0.4 0 0.4 0.4 23 5 30 305 1 0 1 0 0.6 0.1 1 0.6 10/26/2004 15:50:00 15.8 1.5 19.5 11.1 15.8 1.5 19.9 11.5 0.4 0 0.4 0.4 23 5 22 305 1 0 1 0 0.8 0 1 0.6 10/26/2004 16:00:00 16.4 1.5 19.9 12.2 16.3 1.6 19.9 12.6 0.4 0 0.4 0.4 24 5 23 305 1 0 1 0 0.8 0 1.3 0.6 10/26/2004 16:10:00 17 1.3 20.6 13.3 16.8 1.5 21 12.6 0.4 0 0.4 0.4 23 4 23 305 1 0 1 0 0.8 0 1.3 0.6 10/26/2004 16:20:00 17 1.3 19.9 12.6 16.9 1.3 19.9 13.3 0.4 0 0.4 0.4 25 4 29 305 1 0 1 0 0.9 0 1.3 0.6 10/26/2004 16:30:00 17.3 1.2 19.9 14.1 17.2 1.2 20.2 14.1 0.4 0 0.4 0.4 24 4 23 305 1 0 1 0 1.1 0 1.5 1 10/26/2004 16:40:00 16.2 1.5 19.9 12.6 15.9 1.7 19.9 11.8 0.4 0 0.4 0.4 24 4 22 305 1 0 1 0 1.2 0.1 1.5 1 10/26/2004 16:50:00 16.6 1.4 19.1 12.6 16.4 1.5 19.1 13 0.4 0 0.4 0.4 24 4 24 305 1 0 1 0 1.1 0.1 1.5 1 10/26/2004 17:00:00 16.3 1.3 19.5 13 16.2 1.3 19.1 12.6 0.4 0 0.4 0.4 23 5 23 305 1 0 1 0 1.1 0.1 1.5 1 10/26/2004 17:10:00 17.1 1.7 20.6 12.6 16.9 1.7 20.6 12.6 0.4 0 0.4 0.4 22 4 21 305 1 0 1 0 1.1 0 1.5 1 10/26/2004 17:20:00 16.2 1.5 19.9 11.8 16 1.7 19.9 11.8 0.4 0 0.4 0.4 23 5 22 305 1 0 1 0 1.2 0.1 1.7 1 10/26/2004 17:30:00 16.5 1.5 19.5 13 16.4 1.5 19.9 12.2 0.4 0 0.4 0.4 22 5 19 305 1 0 1 0 1.2 0.1 1.5 1 10/26/2004 17:40:00 17 1.3 20.6 13.7 16.9 1.3 20.2 14.1 0.4 0 0.4 0.4 18 4 15 305 1 0 1 0 1.1 0 1.7 1 10/26/2004 17:50:00 17 1.3 20.2 13 16.9 1.3 19.9 13.3 0.4 0 0.4 0.4 20 4 16 305 1 0 1 0 1 0 1.5 0.8 10/26/2004 18:00:00 16.7 1.5 20.2 12.6 16.6 1.6 20.2 12.2 0.4 0 0.4 0.4 21 4 24 305 1 0 1 0 1.1 0 1.5 1 10/26/2004 18:10:00 16.6 1.3 19.1 13 16.5 1.3 19.5 11.8 0.4 0 0.4 0.4 21 4 32 305 1 0 1 0 0.9 0.1 1.5 0.6 10/26/2004 18:20:00 15.5 1.3 18.7 11.8 15.4 1.4 18.7 12.6 0.4 0 0.4 0.4 19 3 22 305 1 0 1 0 0.8 0 1.3 0.6 10/26/2004 18:30:00 16.6 1.4 20.2 13 16.7 1.5 20.2 12.6 0.4 0 0.4 0.4 19 4 13 305 1 0 1 0 0.6 0.1 1 0.6 10/26/2004 18:40:00 14.9 1.3 18.3 11.1 15.3 1.2 18.7 11.8 0.4 0 0.4 0.4 20 4 15 305 1 0 1 0 0.7 0 1 0.6 10/26/2004 18:50:00 15.4 1.8 19.9 11.5 15.3 1.9 20.2 11.1 0.4 0 0.4 0.4 19 4 16 305 1 0 1 0 0.7 0 1 0.6 10/26/2004 19:00:00 15.4 1.4 18.7 11.5 15.4 1.4 18.7 11.5 0.4 0 0.4 0.4 18 4 17 305 1 0 1 0 1 0 1 0.8 10/26/2004 19:10:00 15 1.3 18.3 12.2 15 1.4 18.3 11.5 0.4 0 0.4 0.4 18 4 18 305 1 0 1 0 1 0 1.3 1 10/26/2004 19:20:00 14.7 1.2 18.3 11.8 14.6 1.3 19.1 10.7 0.4 0 0.4 0.4 19 4 24 305 1 0 1 0 1.1 0 1.3 1 10/26/2004 19:30:00 15.3 1.3 19.1 11.8 15.4 1.4 18.7 11.8 0.4 0 0.4 0.4 22 5 21 305 1 0 1 0 1.2 0 1.5 1 10/26/2004 19:40:00 16.1 1.5 19.5 12.2 15.9 1.5 19.5 12.2 0.4 0 0.4 0.4 21 5 22 305 1 0 1 0 1.3 0 1.5 1.3 10/26/2004 19:50:00 16.5 1.5 20.2 13 16.2 1.5 20.2 13 0.4 0 0.4 0.4 19 4 22 305 1 0 1 0 1.3 0 2 1.3 10/26/2004 20:00:00 16.8 1.3 19.5 13.3 16.6 1.4 19.5 13 0.4 0 0.4 0.4 21 4 19 305 1 0 1 0 1.4 0 1.7 1.3 10/26/2004 20:10:00 15.6 1.4 19.1 12.2 15.3 1.5 19.5 12.2 0.4 0 0.4 0.4 20 5 20 305 1 0 1 0 1.5 0 2 1.3 10/26/2004 20:20:00 15.5 1.3 18.7 12.2 15.4 1.4 18.7 11.5 0.4 0 0.4 0.4 21 4 22 305 1 0 1 0 1.6 0 2 1.5 10/26/2004 20:30:00 16.1 1.4 19.1 12.2 15.8 1.4 19.1 12.6 0.4 0 0.4 0.4 20 5 21 305 1 0 1 0 1.6 0 2.2 1.5 10/26/2004 20:40:00 16.2 1.3 19.5 12.6 16.2 1.2 19.1 13 0.4 0 0.4 0.4 19 3 18 305 1 0 1 0 1.6 0 2 1.5 10/26/2004 20:50:00 15.6 1.3 18.3 12.6 15.4 1.4 18.7 11.8 0.4 0 0.4 0.4 19 4 16 305 1 0 1 0 1.6 0 2 1.5 10/26/2004 21:00:00 16.2 1.2 19.1 13 16.1 1.3 19.1 12.6 0.4 0 0.4 0.4 21 4 21 305 1 0 1 0 1.6 0 2 1.5 10/26/2004 21:10:00 15.9 1 17.9 12.6 15.9 1.1 17.9 12.2 0.4 0 0.4 0.4 23 4 26 305 1 0 1 0 1.4 0.1 2 1 10/26/2004 21:20:00 16.2 1.2 18.7 12.6 16.1 1.3 18.7 12.2 0.4 0 0.4 0.4 19 3 17 305 1 0 1 0 1.3 0 2 1.3 10/26/2004 21:30:00 15.7 1.3 18.7 11.8 15.5 1.5 18.7 11.1 0.4 0 0.4 0.4 21 4 27 305 1 0 1 0 1.6 0 2 1.3 10/26/2004 21:40:00 15.6 1.2 17.9 11.8 15.5 1.3 17.9 11.8 0.4 0 0.4 0.4 19 4 17 305 1 0 1 0 1.5 0 2 1.3 10/26/2004 21:50:00 15.7 1.2 18.3 13 15.5 1.3 18.7 12.2 0.4 0 0.4 0.4 19 4 20 305 1 0 1 0 1.6 0.1 2.2 1.5 10/26/2004 22:00:00 16.4 1.3 19.5 12.2 16.3 1.4 19.1 13 0.4 0 0.4 0.4 22 4 18 305 1 0 1 0 1.8 0.1 2.2 1.5 10/26/2004 22:10:00 16.4 1 18.7 13 16.2 1.1 18.7 13 0.4 0 0.4 0.4 22 3 29 305 2 0 1 0 1.9 0 2.2 1.7 10/26/2004 22:20:00 16.1 1.4 19.1 11.8 15.9 1.5 19.1 11.8 0.4 0 0.4 0.4 21 4 25 305 2 0 2 0 1.7 0.1 2.2 1.5 10/26/2004 22:30:00 15.7 1.2 19.1 12.6 15.6 1.3 18.3 11.5 0.4 0 0.4 0.4 19 4 10 305 2 0 2 0 1.6 0 2.2 1.5 10/26/2004 22:40:00 15.9 1 18.3 13 15.7 1 18.7 12.6 0.4 0 0.4 0.4 19 3 22 305 2 0 2 0 1.7 0.1 2.2 1.5 10/26/2004 22:50:00 15.2 1.3 17.6 11.8 15.2 1.3 17.6 12.2 0.4 0 0.4 0.4 21 4 18 305 2 0 2 0 1.8 0 2.5 1.5 10/26/2004 23:00:00 15.3 1.1 17.6 12.6 15.1 1.2 17.9 11.8 0.4 0 0.4 0.4 21 4 18 305 2 0 2 0 1.9 0 2.2 2 10/26/2004 23:10:00 14.9 1.2 17.2 11.5 14.8 1.2 17.2 10.7 0.4 0 0.4 0.4 20 4 23 305 2 0 2 0 2 0 2.5 2 10/26/2004 23:20:00 14.4 1.1 17.2 11.5 14.4 1.1 17.2 11.1 0.4 0 0.4 0.4 20 3 23 305 2 0 2 0 2.1 0 2.5 2 10/26/2004 23:30:00 14.9 1 17.2 11.8 14.8 1 17.2 11.8 0.4 0 0.4 0.4 20 3 24 305 2 0 2 0 2.1 0 2.7 2 10/26/2004 23:40:00 14.2 1 16.4 11.5 14.1 1.1 16.4 11.1 0.4 0 0.4 0.4 19 3 14 305 2 0 2 0 2.2 0 2.7 2 10/26/2004 23:50:00 14.4 1 16.4 12.2 14.3 1 16.8 11.5 0.4 0 0.4 0.4 20 4 19 305 2 0 2 0 2.2 0.1 2.9 2 10/27/2004 00:00:00 14.2 0.9 16.4 11.8 14.2 1 16.4 11.5 0.4 0 0.4 0.4 17 3 20 305 2 0 2 0 2.2 0.1 2.7 2.2 10/27/2004 00:10:00 13.3 1.1 16.4 10.7 13.2 1.2 16.4 10.3 0.4 0 0.4 0.4 18 4 16 305 2 0 2 0 2.3 0 2.7 2.2 10/27/2004 00:20:00 14.1 1.3 16.4 9.9 13.9 1.4 16.4 9.9 0.4 0 0.4 0.4 22 4 24 305 2 0 2 0 2.3 0 2.9 2.2 10/27/2004 00:30:00 14.3 1.1 16.8 11.8 14.3 1.2 16.8 11.1 0.4 0 0.4 0.4 25 3 23 305 2 0 2 0 2.2 0 2.7 2 10/27/2004 00:40:00 14.4 0.9 16.8 12.2 14.2 1 16.8 12.2 0.4 0 0.4 0.4 25 3 27 305 2 0 2 0 2.1 0 2.7 2 10/27/2004 00:50:00 14.1 1 16.1 11.1 13.9 1 16.8 11.1 0.4 0 0.4 0.4 22 4 23 305 2 0 2 0 1.9 0 2.5 1.7 10/27/2004 01:00:00 13.4 1.1 16.1 10.3 13.4 1.1 16.1 9.9 0.4 0 0.4 0.4 21 4 20 305 2 0 2 0 2 0 2.5 1.7 10/27/2004 01:10:00 14 0.8 16.1 11.5 13.9 0.9 15.6 11.5 0.4 0 0.4 0.4 21 4 21 305 2 0 2 0 2.1 0 2.7 2 10/27/2004 01:20:00 13.6 0.8 15.3 11.5 13.5 1 15.6 11.5 0.4 0 0.4 0.4 21 4 17 305 2 0 2 0 2 0.1 2.7 2 10/27/2004 01:30:00 14 0.9 15.6 11.1 14 1 16.1 11.5 0.4 0 0.4 0.4 20 3 22 305 2 0 2 0 2.3 0.1 2.7 2.2 10/27/2004 01:40:00 13 1.1 15.3 10.3 12.9 1.1 15.3 9.9 0.4 0 0.4 0.4 19 4 21 305 2 0 2 0 2.3 0 2.7 2.2 10/27/2004 01:50:00 13.3 0.9 15.3 10.7 13.3 0.9 15.6 10.7 0.4 0 0.4 0.4 20 3 19 305 2 0 2 0 2.3 0.1 2.9 2.2 10/27/2004 02:00:00 13.6 0.8 15.3 10.3 13.5 0.9 15.6 10.7 0.4 0 0.4 0.4 19 3 20 305 2 0 2 0 2.3 0 2.5 2.2 10/27/2004 02:10:00 14 0.7 15.6 11.1 13.9 0.9 15.6 11.1 0.4 0 0.4 0.4 18 3 12 305 2 0 2 0 2.2 0.1 2.9 2.2 10/27/2004 02:20:00 13.5 0.8 15.3 10.7 13.5 0.9 15.3 10.7 0.4 0 0.4 0.4 21 3 17 305 2 0 2 0 2.1 0 2.7 2 10/27/2004 02:30:00 13 0.8 14.9 10.3 13 0.9 15.3 10.7 0.4 0 0.4 0.4 20 3 21 305 2 0 2 0 1.9 0.1 2.7 1.7 10/27/2004 02:40:00 12.9 1 14.9 10.3 12.9 1 15.3 9.5 0.4 0 0.4 0.4 19 3 17 305 2 0 2 0 2.3 0 2.9 2.2 10/27/2004 02:50:00 13.6 1 15.6 11.1 13.5 1.1 15.6 10.7 0.4 0 0.4 0.4 20 3 19 305 2 0 2 0 2.4 0 2.9 2.2 10/27/2004 03:00:00 13.6 0.9 15.6 11.1 13.5 1 15.3 11.1 0.4 0 0.4 0.4 20 3 26 305 2 0 2 0 2.5 0 2.9 2.2 10/27/2004 03:10:00 12.7 0.7 14.5 10.7 12.6 0.8 14.5 10.3 0.4 0 0.4 0.4 21 5 21 305 2 0 2 0 2.4 0 3.2 2.2 10/27/2004 03:20:00 13.2 1 15.6 10.3 13.1 1 15.6 10.3 0.4 0 0.4 0.4 23 3 24 305 2 0 2 0 2.6 0 3.2 2.2 10/27/2004 03:30:00 14.2 1 16.1 11.1 13.9 1.1 16.1 10.7 0.4 0 0.4 0.4 28 4 28 305 2 0 2 0 2.5 0 2.9 2.2 10/27/2004 03:40:00 14.3 1.1 17.2 11.5 14.2 1.2 17.2 11.5 0.4 0 0.4 0.4 22 5 21 305 2 0 2 0 2.2 0 2.7 2 10/27/2004 03:50:00 14.6 1 16.8 12.2 14.5 1 16.8 11.8 0.4 0 0.4 0.4 18 3 19 305 2 0 2 0 2.2 0 2.7 2.2 10/27/2004 04:00:00 14.5 1 16.4 11.8 14.4 1 16.4 11.5 0.4 0 0.4 0.4 17 4 15 305 2 0 2 0 2.2 0 2.7 2 10/27/2004 04:10:00 15 1 17.2 12.2 14.9 1 17.6 11.8 0.4 0 0.4 0.4 18 3 18 305 2 0 2 0 2 0 2.7 1.7 10/27/2004 04:20:00 15.1 1.5 18.7 11.5 15 1.6 18.3 11.1 0.4 0 0.4 0.4 21 4 22 305 2 0 2 0 2.2 0 2.5 2 10/27/2004 04:30:00 15.2 1.2 17.6 11.8 15.1 1.2 17.6 11.5 0.4 0 0.4 0.4 20 4 18 305 2 0 2 0 2.2 0 2.5 2.2 10/27/2004 04:40:00 16.1 1.2 18.7 13 15.9 1.3 18.7 12.6 0.4 0 0.4 0.4 20 4 18 305 2 0 2 0 2.2 0 2.7 2.2 10/27/2004 04:50:00 16.4 1.2 18.7 13 16.1 1.3 18.7 12.2 0.4 0 0.4 0.4 21 4 23 305 2 0 2 0 2.2 0 2.5 2.2 10/27/2004 05:00:00 16.4 1.3 19.5 12.6 16.2 1.4 19.1 13 0.4 0 0.4 0.4 20 4 21 305 2 0 2 0 2.2 0 2.7 2 10/27/2004 05:10:00 17.2 1.1 19.5 13.3 17 1.1 19.5 12.6 0.4 0 0.4 0.4 22 4 20 305 2 0 2 0 2.2 0 2.7 2.2 10/27/2004 05:20:00 16.1 1.3 19.1 13 15.9 1.3 19.1 12.6 0.4 0 0.4 0.4 22 4 19 305 2 0 2 0 2.3 0 2.9 2.2 10/27/2004 05:30:00 16.4 1.3 18.7 13 16.2 1.4 19.5 12.2 0.4 0 0.4 0.4 22 5 21 305 2 0 2 0 2.3 0 2.7 2.2 10/27/2004 05:40:00 15.6 1.3 19.5 11.5 15.6 1.3 19.1 10.7 0.4 0 0.4 0.4 21 4 15 305 2 0 2 0 2.3 0 2.9 2.2 10/27/2004 05:50:00 16.3 1.2 19.1 13 16.2 1.3 18.7 13 0.4 0 0.4 0.4 21 4 22 305 2 0 2 0 2.4 0 2.9 2.2 10/27/2004 06:00:00 16.3 1.1 18.7 12.6 16.1 1.2 18.7 12.6 0.4 0 0.4 0.4 20 4 26 305 2 0 2 0 2.5 0 2.9 2.2 10/27/2004 06:10:00 16.6 1.5 19.5 13 16.4 1.6 19.9 13 0.4 0 0.4 0.4 18 4 16 305 2 0 2 0 2.4 0.1 2.9 2.2 10/27/2004 06:20:00 16.4 1.3 19.9 12.6 16.3 1.3 19.9 13 0.4 0 0.4 0.4 21 4 23 305 2 0 2 0 2.3 0.1 2.9 2.2 10/27/2004 06:30:00 16.5 1.2 19.1 13.7 16.2 1.3 19.5 13.7 0.4 0 0.4 0.4 19 4 18 305 2 0 2 0 2.3 0.1 2.7 2.2 10/27/2004 06:40:00 16.7 1.4 19.9 12.2 16.6 1.5 19.9 12.2 0.4 0 0.4 0.4 18 4 20 305 2 0 2 0 2.2 0 2.7 2 10/27/2004 06:50:00 17.3 1 19.9 13.7 17.3 1.2 20.2 13.3 0.4 0 0.4 0.4 17 4 14 305 2 0 2 0 2.2 0 2.7 2 10/27/2004 07:00:00 17.3 1.2 20.6 13.7 17.2 1.3 20.6 13.3 0.4 0 0.4 0.4 17 3 21 305 2 0 2 0 2.2 0 2.7 2 10/27/2004 07:10:00 16.8 1.4 19.9 12.2 16.8 1.5 19.9 11.5 0.4 0 0.4 0.4 16 4 24 305 2 0 2 0 2.1 0 2.7 2 10/27/2004 07:20:00 16.5 1.5 20.6 13 16.3 1.5 20.2 12.6 0.4 0 0.4 0.4 16 4 18 305 2 0 2 0 2.1 0.1 2.7 2 10/27/2004 07:30:00 15.8 1.5 19.9 11.5 15.7 1.5 19.1 11.8 0.4 0 0.4 0.4 13 5 14 305 2 0 2 0 2.1 0 2.5 2 10/27/2004 07:40:00 16.6 1.7 19.9 12.2 16.6 1.7 20.2 12.2 0.4 0 0.4 0.4 13 4 15 305 2 0 2 0 1.9 0.1 2.5 1.7 10/27/2004 07:50:00 17 1.3 20.2 11.8 16.8 1.5 20.2 11.8 0.4 0 0.4 0.4 13 4 13 305 2 0 2 0 1.9 0.1 2.5 1.7 10/27/2004 08:00:00 17.1 1.5 20.2 13.3 16.9 1.6 20.6 13.3 0.4 0 0.4 0.4 10 4 10 305 2 0 2 0 1.9 0.1 2.5 1.5 10/27/2004 08:10:00 17.3 1.5 19.9 13 17.3 1.5 20.2 13 0.4 0 0.4 0.4 11 4 12 305 2 0 2 0 1.7 0.1 2.2 1.5 10/27/2004 08:20:00 17 1.7 20.6 11.8 16.9 1.7 21 12.2 0.4 0 0.4 0.4 8 4 7 305 2 0 2 0 1.6 0 2.2 1.5 10/27/2004 08:30:00 17.3 1.3 19.9 13 17.2 1.3 19.9 13 0.4 0 0.4 0.4 7 4 8 305 2 0 2 0 1.6 0 2 1.3 10/27/2004 08:40:00 17.3 1.5 21 13.3 17.3 1.5 21 13 0.4 0 0.4 0.4 9 4 13 305 2 0 2 0 1.5 0 2 1.3 10/27/2004 08:50:00 17.4 1.5 21 13.7 17.4 1.5 21 13.7 0.4 0 0.4 0.4 8 4 6 305 2 0 2 0 1.4 0 2 1.3 10/27/2004 09:00:00 17 1.3 20.2 13 16.8 1.3 20.2 13.3 0.4 0 0.4 0.4 6 4 2 305 2 0 2 0 1.4 0 2 1.3 10/27/2004 09:10:00 16.5 1.3 19.5 13 16.5 1.4 19.5 13 0.4 0 0.4 0.4 6 4 5 305 2 0 2 0 1.5 0 2 1.3 10/27/2004 09:20:00 15.9 1.5 19.5 11.5 15.9 1.5 18.7 12.2 0.4 0 0.4 0.4 6 4 4 305 2 0 2 0 1.5 0 2.2 1.3 10/27/2004 09:30:00 16 1.6 19.9 11.1 16 1.7 19.5 11.5 0.4 0 0.4 0.4 9 5 8 305 2 0 2 0 1.6 0 2.2 1.3 10/27/2004 09:40:00 17 1.6 20.6 13 17 1.6 20.6 13 0.4 0 0.4 0.4 7 4 11 305 2 0 2 0 1.6 0 2.2 1.5 10/27/2004 09:50:00 17.2 1.5 20.6 13 17 1.5 20.6 13 0.4 0 0.4 0.4 8 4 5 305 2 0 2 0 1.6 0 2.2 1.5 10/27/2004 10:00:00 17.6 1.5 21.8 13.7 17.5 1.6 22.1 13.3 0.4 0 0.4 0.4 9 4 11 305 2 0 2 0 1.6 0 2 1.5 10/27/2004 10:10:00 17.3 1.8 22.1 12.6 17.1 1.9 21.8 12.6 0.4 0 0.4 0.4 9 4 15 305 2 0 2 0 1.6 0 2.2 1.5 10/27/2004 10:20:00 18.2 1.6 21.8 13.7 18.1 1.6 21.8 13.7 0.4 0 0.4 0.4 7 4 7 305 2 0 2 0 1.6 0 2 1.5 10/27/2004 10:30:00 16.1 1.5 20.6 11.8 16 1.6 20.2 12.2 0.4 0 0.4 0.4 7 5 3 305 2 0 2 0 1.6 0 2.2 1.5 10/27/2004 10:40:00 16.8 1.6 21 12.2 16.8 1.6 21 12.2 0.4 0 0.4 0.4 5 4 9 305 2 0 2 0 1.6 0 2 1.3 10/27/2004 10:50:00 16.8 1.8 20.6 11.8 16.6 1.8 20.2 11.8 0.4 0 0.4 0.4 6 4 8 305 2 0 2 0 1.5 0.1 2 1.3 10/27/2004 11:00:00 17.5 1.5 20.2 12.6 17.4 1.6 20.2 12.2 0.4 0 0.4 0.4 7 4 8 305 2 0 2 0 1.4 0 2 1.3 10/27/2004 11:10:00 17.7 1.3 21 14.5 17.5 1.3 21 14.1 0.4 0 0.4 0.4 7 4 4 305 2 0 2 0 1.4 0 2 1.3 10/27/2004 11:20:00 17.8 1.4 21 13.7 17.8 1.5 21 12.6 0.4 0 0.4 0.4 6 4 5 305 2 0 2 0 1.3 0 2 1.3 10/27/2004 11:30:00 17.2 1.2 20.2 13.3 17.2 1.3 19.9 14.1 0.4 0 0.4 0.4 5 4 4 305 2 0 2 0 1.3 0.1 1.7 1 10/27/2004 11:40:00 17.4 1.5 20.6 13.3 17.3 1.5 21 12.6 0.4 0 0.4 0.4 7 4 8 305 2 0 2 0 1.3 0.1 1.7 1 10/27/2004 11:50:00 17.5 1.2 20.2 14.1 17.5 1.2 19.9 14.1 0.4 0 0.4 0.4 5 3 0 305 2 0 2 0 1.3 0.1 2 1 10/27/2004 12:00:00 16.8 1.4 19.9 13.3 16.8 1.5 20.2 13.3 0.4 0 0.4 0.4 7 5 8 305 2 0 2 0 1.2 0.1 1.7 1 10/27/2004 12:10:00 17.9 1.7 21.4 13.7 17.8 1.7 21 12.6 0.4 0 0.4 0.4 6 4 4 305 2 0 2 0 1.2 0.1 1.7 1 10/27/2004 12:20:00 18 1.3 20.6 13.7 18 1.4 21 13.7 0.4 0 0.4 0.4 5 3 1 305 2 0 2 0 1.2 0.1 1.7 1 10/27/2004 12:30:00 18.6 1.4 21.8 15.3 18.5 1.5 21.4 14.1 0.4 0 0.4 0.4 6 3 4 305 2 0 2 0 1.1 0 1.5 1 10/27/2004 12:40:00 17.9 1.3 21 13.7 17.8 1.5 21 13.7 0.4 0 0.4 0.4 8 4 5 305 2 0 2 0 1.1 0.1 1.5 1 10/27/2004 12:50:00 17.4 1.2 20.2 13 17.4 1.3 20.2 13.3 0.4 0 0.4 0.4 5 4 4 305 2 0 2 0 1 0.1 1.5 0.6 10/27/2004 13:00:00 17.2 1.5 21 13.7 17.2 1.6 21 13 0.4 0 0.4 0.4 6 4 1 305 2 0 2 0 0.9 0 1.5 0.6 10/27/2004 13:10:00 17.2 1.7 21.8 12.6 17.1 1.9 21.4 12.6 0.4 0 0.4 0.4 3 4 358 305 2 0 2 0 0.8 0.1 1.5 0.6 10/27/2004 13:20:00 17.9 1.6 22.1 14.5 17.7 1.7 21.8 13.3 0.4 0 0.4 0.4 4 4 2 305 2 0 2 0 0.7 0.1 1.3 0.6 10/27/2004 13:30:00 18.2 1.7 21.8 12.6 18.2 1.7 21.8 13.3 0.4 0 0.4 0.4 6 4 3 305 2 0 2 0 0.6 0.1 1.3 0.6 10/27/2004 13:40:00 18.1 1.7 21.4 13 18.2 1.8 21.8 13.3 0.4 0 0.4 0.4 6 4 2 305 2 0 2 0 0.6 0.1 1.3 0.6 10/27/2004 13:50:00 18.2 1.5 21.8 14.5 18.2 1.5 21.4 14.5 0.4 0 0.4 0.4 5 4 359 305 2 0 2 0 0.6 0.1 1.3 0.6 10/27/2004 14:00:00 17.6 1.9 21.8 12.2 17.3 1.9 21.8 12.2 0.4 0 0.4 0.4 6 5 10 305 2 0 2 0 0.6 0.1 1.3 0.6 10/27/2004 14:10:00 18.4 1.2 21 14.9 18.1 1.2 22.1 14.9 0.4 0 0.4 0.4 4 3 2 305 2 0 2 0 0.6 0 1 0.6 10/27/2004 14:20:00 18.2 1.7 21.4 13 17.9 1.8 21.8 12.2 0.4 0 0.4 0.4 5 4 5 305 2 0 2 0 0.5 0 1 0.3 10/27/2004 14:30:00 18.4 2 22.1 13.3 18.2 2.2 22.6 12.6 0.4 0 0.4 0.4 5 4 9 305 2 0 2 0 0.6 0 1.3 0.3 10/27/2004 14:40:00 18 1.5 21.8 14.1 18.1 1.5 21.8 14.1 0.4 0 0.4 0.4 4 5 5 305 2 0 2 0 0.5 0 1 0.3 10/27/2004 14:50:00 17.9 1.5 21.4 13.7 18 1.6 21.4 13 0.4 0 0.4 0.4 4 5 3 305 2 0 2 0 0.6 0 1.3 0.6 10/27/2004 15:00:00 17.6 1.7 22.9 13.3 17.3 1.7 23.3 13 0.4 0 0.4 0.4 6 4 9 305 2 0 2 0 0.7 0.1 1.3 0.6 10/27/2004 15:10:00 19 1.7 22.6 14.5 18.7 1.7 22.6 13 0.4 0 0.4 0.4 2 4 3 305 2 0 2 0 0.5 0 1 0.3 10/27/2004 15:20:00 18.7 1.9 23.7 14.1 18.2 2 22.6 13.7 0.4 0 0.4 0.4 4 5 9 305 2 0 2 0 0.5 0 1 0.3 10/27/2004 15:30:00 18.9 1.7 24 14.9 18.7 1.7 22.9 12.6 0.4 0 0.4 0.4 3 5 12 305 2 0 2 0 0.5 0 1 0.3 10/27/2004 15:40:00 19.2 1.7 23.3 13.7 18.9 1.7 22.9 13.7 0.4 0 0.4 0.4 6 4 9 305 2 0 2 0 0.5 0 1 0.3 10/27/2004 15:50:00 19 2.1 23.7 13.3 19 2.2 23.3 13.3 0.4 0 0.4 0.4 7 5 9 305 2 0 2 0 0.6 0.1 1.3 0.3 10/27/2004 16:00:00 19 1.9 22.9 14.1 18.8 2 23.3 12.6 0.4 0 0.4 0.4 3 5 2 305 2 0 2 0 0.5 0 1 0.3 10/27/2004 16:10:00 18 2 22.1 13.3 17.7 2 21.8 13 0.4 0 0.4 0.4 4 4 2 305 2 0 2 0 0.5 0 1 0.3 10/27/2004 16:20:00 18.6 1.9 23.3 14.1 18.6 1.8 23.3 13.7 0.4 0 0.4 0.4 5 4 6 305 2 0 2 0 0.5 0 1.3 0.3 10/27/2004 16:30:00 19.1 1.7 23.3 13.3 18.9 1.8 23.7 13.7 0.4 0 0.4 0.4 2 4 3 305 2 0 2 0 0.5 0 1 0.3 10/27/2004 16:40:00 18.5 1.6 21.8 14.1 18.3 1.7 22.6 13.7 0.4 0 0.4 0.4 4 5 3 305 2 0 2 0 0.5 0 1 0.3 10/27/2004 16:50:00 19.5 1.5 22.1 15.6 19.6 1.4 22.9 16.1 0.4 0 0.4 0.4 2 4 358 305 2 0 2 0 0.4 0 1 0.3 10/27/2004 17:00:00 19.1 1.8 23.3 14.1 19 1.7 23.3 14.5 0.4 0 0.4 0.4 2 4 0 305 2 0 2 0 0.3 0 0.8 0.1 10/27/2004 17:10:00 19.2 1.5 23.3 14.5 19.2 1.6 22.9 14.5 0.4 0 0.4 0.4 5 4 5 305 2 0 2 0 0.3 0 0.6 0.3 10/27/2004 17:20:00 18.9 1.6 22.9 14.5 18.7 1.5 22.6 14.9 0.4 0 0.4 0.4 2 4 4 305 2 0 2 0 0.3 0 0.6 0.1 10/27/2004 17:30:00 18.9 1.7 22.9 13 18.8 1.7 23.3 13.3 0.4 0 0.4 0.4 3 5 8 305 2 0 2 0 0.3 0 0.6 0.3 10/27/2004 17:40:00 19.2 1.7 22.6 13.7 19 1.8 22.6 14.1 0.4 0 0.4 0.4 3 4 359 305 2 0 2 0 0.3 0 0.6 0.1 10/27/2004 17:50:00 17.8 2.1 22.6 13.3 17.8 2.1 22.1 13 0.4 0 0.4 0.4 3 4 6 305 2 0 2 0 0.3 0 0.6 0.1 10/27/2004 18:00:00 17.9 1.8 22.6 12.6 17.8 1.7 22.6 12.2 0.4 0 0.4 0.4 4 5 3 305 2 0 2 0 0.4 0 1 0.3 10/27/2004 18:10:00 19.4 1.6 22.9 14.5 19.4 1.7 22.9 14.1 0.4 0 0.4 0.4 4 4 5 305 2 0 2 0 0.4 0 1 0.3 10/27/2004 18:20:00 18.2 1.7 21.8 13.7 18.1 1.9 22.1 13 0.4 0 0.4 0.4 3 5 5 305 2 0 2 0 0.5 0 1 0.3 10/27/2004 18:30:00 18.6 1.5 21.4 14.1 18.6 1.6 21.8 14.5 0.4 0 0.4 0.4 3 4 0 305 2 0 2 0 0.4 0 0.8 0.1 10/27/2004 18:40:00 18.4 1.5 22.1 13.3 18.4 1.5 22.1 13.7 0.4 0 0.4 0.4 3 4 8 305 2 0 2 0 0.3 0 1 0.1 10/27/2004 18:50:00 18.6 1.9 22.1 13.7 18.6 1.9 22.6 13.3 0.4 0 0.4 0.4 3 5 2 305 2 0 2 0 0.2 0.1 0.8 0.1 10/27/2004 19:00:00 19.9 1.7 24 15.3 19.8 1.7 24 15.3 0.4 0 0.4 0.4 3 4 4 305 2 0 2 0 0.2 0.1 0.6 0.1 10/27/2004 19:10:00 18.8 1.7 22.1 14.1 18.9 1.9 22.6 13.3 0.4 0 0.4 0.4 3 4 3 305 2 0 2 0 0.2 0.1 0.8 0.1 10/27/2004 19:20:00 18.6 1.7 23.3 14.5 18.6 1.7 22.9 13.7 0.4 0 0.4 0.4 4 5 6 305 2 0 2 0 0.3 0 0.8 0.1 10/27/2004 19:30:00 18.7 2 23.3 13.7 18.7 2.3 24.4 11.8 0.4 0 0.4 0.4 5 5 9 305 2 0 2 0 0.4 0 1 0.3 10/27/2004 19:40:00 19.5 1.8 23.3 14.1 19.4 1.9 23.7 14.1 0.4 0 0.4 0.4 4 5 1 305 2 0 2 0 0.4 0 0.8 0.1 10/27/2004 19:50:00 19.3 2.1 24 13 19.3 2.1 24 13.3 0.4 0 0.4 0.4 4 5 3 305 2 0 2 0 0.3 0 1 0.1 10/27/2004 20:00:00 20.8 1.6 24.4 16.4 20.9 1.7 24 16.1 0.4 0 0.4 0.4 5 4 1 305 2 0 2 0 0.2 0 0.3 0.1 10/27/2004 20:10:00 19.5 1.7 23.3 15.3 19.4 1.7 23.3 14.9 0.4 0 0.4 0.4 5 5 6 305 2 0 2 0 0 0 0.3 0.1 10/27/2004 20:20:00 19.7 1.7 23.7 14.9 19.7 1.7 23.7 15.3 0.4 0 0.4 0.4 4 4 3 305 2 0 2 0 0 0 0.1 -0.4 10/27/2004 20:30:00 19.3 1.6 23.3 13.7 19.1 1.7 23.7 14.1 0.4 0 0.4 0.4 3 5 8 305 2 0 2 0 0 0 0.1 -0.1 10/27/2004 20:40:00 20.3 1.7 23.7 14.9 20.1 1.8 23.7 14.5 0.4 0 0.4 0.4 6 4 6 305 2 0 2 0 -0.1 0 0.1 -0.1 10/27/2004 20:50:00 20.6 2.1 24.8 14.1 20.5 2.2 25.2 14.5 0.4 0 0.4 0.4 5 5 4 305 2 0 2 0 -0.1 0 0.1 -0.4 10/27/2004 21:00:00 20.8 1.9 25.2 15.3 20.5 2 24.8 14.5 0.4 0 0.4 0.4 8 5 8 305 2 0 2 0 -0.1 0 0.6 -0.4 10/27/2004 21:10:00 20.5 1.8 24 14.9 20.2 1.9 24.4 14.9 0.4 0 0.4 0.4 5 4 0 305 2 0 2 0 -0.1 0 0.6 -0.4 10/27/2004 21:20:00 20.5 2.2 25.2 15.3 20.2 2.2 24.8 15.6 0.4 0 0.4 0.4 5 5 6 305 2 0 2 0 -0.1 0 0.6 -0.4 10/27/2004 21:30:00 20.2 1.9 24.4 14.9 19.9 2 24.8 15.6 0.4 0 0.4 0.4 6 5 4 305 2 0 2 0 -0.1 0 0.6 -0.4 10/27/2004 21:40:00 21.1 1.7 25.6 16.1 20.8 1.8 24.8 14.9 0.4 0 0.4 0.4 5 4 2 305 2 0 2 0 -0.3 0.1 0.3 -0.6 10/27/2004 21:50:00 20.5 1.8 24.4 16.4 20.1 1.8 24.8 15.3 0.4 0 0.4 0.4 5 5 4 305 2 0 2 0 -0.4 0.1 0.1 -0.6 10/27/2004 22:00:00 21.1 1.8 24.8 15.6 20.8 1.9 24.8 15.6 0.4 0 0.4 0.4 8 4 5 305 3 0 2 0 -0.4 0.1 0.1 -0.6 10/27/2004 22:10:00 20.1 1.7 23.7 15.3 19.8 1.7 24 15.6 0.4 0 0.4 0.4 8 5 5 305 2 0 2 0 -0.3 0 0.3 -0.6 10/27/2004 22:20:00 20.6 1.6 24.8 15.6 20.4 1.7 24.8 14.5 0.4 0 0.4 0.4 6 4 8 305 2 0 2 0 -0.3 0 0.1 -0.6 10/27/2004 22:30:00 20.7 1.8 24.8 15.3 20.3 1.7 24.4 16.4 0.4 0 0.4 0.4 8 5 7 305 2 0 2 0 -0.4 0.1 0.1 -0.6 10/27/2004 22:40:00 21.7 1.7 25.2 15.3 21.3 1.8 24.8 15.6 0.4 0 0.4 0.4 8 4 8 305 2 0 2 0 -0.5 0 0.1 -0.6 10/27/2004 22:50:00 21 1.9 24.8 15.6 20.8 2 24.8 15.3 0.4 0 0.4 0.4 9 5 9 305 2 0 2 0 -0.6 0 0.1 -0.6 10/27/2004 23:00:00 21.6 1.9 25.6 16.1 21.3 1.9 25.2 15.3 0.4 0 0.4 0.4 8 4 11 305 2 0 2 0 -0.7 0 -0.4 -1.1 10/27/2004 23:10:00 21 2 26 15.3 20.6 2.1 26.3 15.6 0.4 0 0.4 0.4 7 4 10 305 2 0 2 0 -0.6 0 0.1 -0.8 10/27/2004 23:20:00 21 1.6 25.2 16.8 20.8 1.7 24.4 15.6 0.4 0 0.4 0.4 8 4 7 305 2 0 2 0 -0.7 0 -0.1 -0.8 10/27/2004 23:30:00 20.6 1.7 24.4 15.3 20.3 1.8 25.2 14.9 0.4 0 0.4 0.4 9 5 8 305 2 0 3 0 -0.6 0 0.1 -0.6 10/27/2004 23:40:00 21.2 2.2 25.2 15.6 20.9 2.3 25.2 14.9 0.4 0 0.4 0.4 9 5 3 305 3 0 2 0 -0.6 0 0.1 -0.8 10/27/2004 23:50:00 20.9 1.6 24.8 16.8 20.7 1.7 25.2 16.8 0.4 0 0.4 0.4 8 5 10 305 2 0 2 0 -0.6 0 -0.1 -0.6 10/28/2004 00:00:00 19.6 2.3 24 14.1 19.4 2.4 24 13.7 0.4 0 0.4 0.4 9 5 7 305 3 0 2 0 -0.5 0 0.1 -0.6 10/28/2004 00:10:00 21.9 1.9 25.6 16.1 21.6 2 26 16.1 0.4 0 0.4 0.4 11 4 5 305 2 0 2 0 -0.6 0 -0.1 -0.6 10/28/2004 00:20:00 21.6 1.6 26 17.2 21.1 1.7 25.6 17.2 0.4 0 0.4 0.4 12 4 12 305 2 0 2 0 -0.6 0 -0.1 -0.6 10/28/2004 00:30:00 21.1 1.9 25.6 16.4 20.8 2 25.2 16.4 0.4 0 0.4 0.4 10 5 10 305 2 0 2 0 -0.7 0 -0.4 -0.8 10/28/2004 00:40:00 21.2 1.7 25.2 16.4 20.7 1.8 25.2 16.4 0.4 0 0.4 0.4 9 5 5 305 2 0 2 0 -0.7 0 0.1 -0.8 10/28/2004 00:50:00 21.6 2 25.2 14.1 21.2 2 25.6 14.1 0.4 0 0.4 0.4 11 5 12 305 3 0 2 0 -0.7 0 -0.4 -0.8 10/28/2004 01:00:00 22.6 1.7 26 16.8 22.1 1.9 26.3 16.4 0.4 0 0.4 0.4 11 4 12 305 3 0 3 0 -0.8 0 -0.4 -0.8 10/28/2004 01:10:00 22.8 1.8 27.1 17.6 22.3 1.7 26.3 17.6 0.4 0 0.4 0.4 14 5 15 305 2 0 2 0 -0.8 0 -0.4 -1.1 10/28/2004 01:20:00 22.1 2.1 26 15.6 21.6 2.1 26 15.3 0.4 0 0.4 0.4 15 5 10 305 3 0 2 0 -0.7 0 -0.1 -1.1 10/28/2004 01:30:00 22.1 1.8 26.3 17.2 21.4 1.7 26 16.8 0.4 0 0.4 0.4 15 5 15 305 3 0 2 0 -0.7 0 -0.1 -1.1 10/28/2004 01:40:00 22.2 1.7 26.3 17.2 21.4 1.7 25.6 16.8 0.4 0 0.4 0.4 14 4 22 305 3 0 2 0 -0.7 0 -0.1 -0.8 10/28/2004 01:50:00 21.5 1.6 24.8 17.6 21.3 1.5 25.6 17.2 0.4 0 0.4 0.4 15 4 15 305 3 0 2 0 -0.6 0 -0.1 -0.6 10/28/2004 02:00:00 21 1.9 26 15.6 20.7 2 26 15.3 0.4 0 0.4 0.4 16 5 14 305 3 0 2 0 -0.6 0 0.1 -0.6 10/28/2004 02:10:00 20.9 1.8 25.2 16.1 20.6 1.9 25.2 15.6 0.4 0 0.4 0.4 19 5 22 305 3 0 3 0 -0.6 0 0.1 -0.6 10/28/2004 02:20:00 21.9 1.8 25.6 16.1 21.7 1.9 26 14.9 0.4 0 0.4 0.4 18 5 18 305 3 0 2 0 -0.7 0 -0.1 -0.8 10/28/2004 02:30:00 22.5 1.7 25.6 16.8 22.1 1.8 25.6 16.4 0.4 0 0.4 0.4 16 4 13 305 3 0 2 0 -0.7 0 -0.1 -1.1 10/28/2004 02:40:00 21.7 1.7 25.6 17.6 21.4 1.9 25.6 16.8 0.4 0 0.4 0.4 14 4 16 305 3 0 3 0 -0.9 0.1 -0.4 -1.1 10/28/2004 02:50:00 21.1 1.6 24 16.4 20.8 1.7 24.4 16.4 0.4 0 0.4 0.4 16 4 8 305 3 0 3 0 -1 0.1 -0.4 -1.1 10/28/2004 03:00:00 20.7 1.5 24 15.6 20.4 1.7 24 15.6 0.4 0 0.4 0.4 20 4 22 305 3 0 3 0 -0.9 0 -0.6 -1.1 10/28/2004 03:10:00 21.1 1.8 24.4 14.9 21 2 24.8 14.9 0.4 0 0.4 0.4 20 4 16 305 3 0 3 0 -1.1 0 -0.8 -1.3 10/28/2004 03:20:00 20.6 1.7 24.8 15.6 20.4 1.9 24.8 15.3 0.4 0 0.4 0.4 21 5 19 305 3 0 3 0 -1.1 0 -1.1 -1.3 10/28/2004 03:30:00 20.4 1.6 24 16.8 20.3 1.7 23.7 16.8 0.4 0 0.4 0.4 20 5 18 305 3 0 2 0 -1.1 0 -0.6 -1.3 10/28/2004 03:40:00 19.8 1.7 23.3 15.3 19.5 1.9 23.3 14.9 0.4 0 0.4 0.4 23 5 17 305 3 0 3 0 -1 0 -0.8 -1.1 10/28/2004 03:50:00 19.8 1.7 23.7 15.3 19.5 1.9 23.7 14.1 0.4 0 0.4 0.4 18 5 14 305 3 0 3 0 -1 0 -0.6 -1.3 10/28/2004 04:00:00 18.9 1.8 22.9 13.7 18.7 1.8 23.3 13.3 0.4 0 0.4 0.4 24 5 26 305 3 0 3 0 -0.9 0.1 -0.4 -1.1 10/28/2004 04:10:00 19.1 1.7 22.9 14.1 18.8 1.7 22.6 14.1 0.4 0 0.4 0.4 23 5 25 305 3 0 3 0 -1 0.1 -0.4 -1.1 10/28/2004 04:20:00 18.9 1.7 22.6 13.3 18.7 1.8 22.9 13.3 0.4 0 0.4 0.4 21 5 18 305 3 0 3 0 -1 0 -0.4 -1.1 10/28/2004 04:30:00 19.2 1.5 22.1 14.9 18.9 1.5 22.6 14.9 0.4 0 0.4 0.4 20 5 14 305 3 0 3 0 -0.8 0 -0.4 -1.1 10/28/2004 04:40:00 18.7 1.3 21.8 14.9 18.6 1.5 22.1 14.5 0.4 0 0.4 0.4 25 4 25 305 3 0 3 0 -0.8 0 -0.4 -0.8 10/28/2004 04:50:00 18.6 1.5 22.6 14.1 18.5 1.6 22.1 14.1 0.4 0 0.4 0.4 21 5 23 305 3 0 3 0 -0.8 0 -0.4 -1.1 10/28/2004 05:00:00 18.5 1.5 21.8 14.1 18.3 1.5 21.8 14.1 0.4 0 0.4 0.4 20 3 20 305 3 0 3 0 -0.7 0 -0.4 -0.8 10/28/2004 05:10:00 18.6 1.4 21.8 13.7 18.4 1.5 21.4 13.7 0.4 0 0.4 0.4 15 4 14 305 3 0 3 0 -0.7 0 0.1 -0.8 10/28/2004 05:20:00 18.3 1.6 21.8 13.3 18 1.7 21.8 13 0.4 0 0.4 0.4 15 4 15 305 3 0 3 0 -0.6 0.1 0.1 -0.8 10/28/2004 05:30:00 18.7 1.5 21.8 13.3 18.6 1.7 21.8 13.7 0.4 0 0.4 0.4 15 4 17 305 3 0 3 0 -0.7 0 -0.1 -1.1 10/28/2004 05:40:00 18.9 1.5 22.1 14.1 18.8 1.5 22.1 14.1 0.4 0 0.4 0.4 16 4 10 305 3 0 2 0 -0.7 0 -0.1 -0.8 10/28/2004 05:50:00 19.1 1.5 22.9 14.1 18.8 1.7 23.3 13.3 0.4 0 0.4 0.4 12 4 11 305 2 0 2 0 -0.7 0 -0.1 -1.1 10/28/2004 06:00:00 18.4 1.8 22.9 13.3 18 1.7 21.8 12.6 0.4 0 0.4 0.4 17 5 19 305 2 0 2 0 -0.7 0 0.1 -0.8 10/28/2004 06:10:00 18.2 1.6 21.8 13.7 18 1.5 21.4 13.7 0.4 0 0.4 0.4 15 5 19 305 2 0 2 0 -0.7 0 0.1 -1.1 10/28/2004 06:20:00 18.5 1.7 22.1 14.5 18.4 1.7 22.1 13.7 0.4 0 0.4 0.4 15 4 23 305 2 0 2 0 -0.7 0.1 -0.1 -1.1 10/28/2004 06:30:00 19.3 1.4 22.1 14.9 19 1.5 21.8 14.9 0.4 0 0.4 0.4 16 4 29 305 2 0 2 0 -0.7 0 -0.1 -0.8 10/28/2004 06:40:00 19.1 1.7 22.9 14.1 18.9 1.7 23.3 14.5 0.4 0 0.4 0.4 13 4 15 305 2 0 2 0 -0.7 0 -0.1 -0.8 10/28/2004 06:50:00 18.2 1.9 22.6 13.3 18 1.9 22.6 13.7 0.4 0 0.4 0.4 13 4 15 305 2 0 2 0 -0.7 0 -0.4 -0.8 10/28/2004 07:00:00 18.8 1.9 22.9 13.7 18.7 1.9 22.6 13 0.4 0 0.4 0.4 13 4 12 305 2 0 2 0 -0.7 0 -0.4 -0.8 10/28/2004 07:10:00 17.3 1.7 21.4 13.3 17.1 1.8 21.4 12.2 0.4 0 0.4 0.4 12 5 10 305 2 0 2 0 -0.5 0.1 -0.4 -0.8 10/28/2004 07:20:00 18.7 1.5 22.1 15.3 18.5 1.6 21.8 14.5 0.4 0 0.4 0.4 13 3 12 305 2 0 2 0 -0.7 0 -0.6 -0.8 10/28/2004 07:30:00 18.3 1.5 21.8 13.3 18.1 1.6 21.8 13.7 0.4 0 0.4 0.4 14 4 15 305 2 0 2 0 -0.9 0.1 -0.6 -1.1 10/28/2004 07:40:00 18.3 1.5 21.8 13.3 18.3 1.7 22.1 13.7 0.4 0 0.4 0.4 9 5 12 305 2 0 2 0 -1.1 0 -0.8 -1.3 10/28/2004 07:50:00 19.3 1.5 22.1 14.5 19.2 1.6 22.6 13.7 0.4 0 0.4 0.4 10 4 9 305 2 0 2 0 -1.3 0 -1.1 -1.3 10/28/2004 08:00:00 18.2 1.5 21.4 13.7 18 1.6 21.8 13.7 0.4 0 0.4 0.4 14 5 10 305 2 0 2 0 -1.1 0 -0.4 -1.3 10/28/2004 08:10:00 18.3 1.6 21.8 12.6 18.3 1.7 21.8 13.3 0.4 0 0.4 0.4 7 4 8 305 3 0 2 0 -0.9 0.1 -0.4 -1.1 10/28/2004 08:20:00 17.8 1.3 21.4 13.7 17.6 1.5 21 13.3 0.4 0 0.4 0.4 11 5 11 305 3 0 2 0 -0.9 0.1 -0.4 -1.1 10/28/2004 08:30:00 18 1.7 21.4 13.3 18 1.7 21.8 13.3 0.4 0 0.4 0.4 11 3 7 305 3 0 3 0 -0.7 0 -0.1 -1.1 10/28/2004 08:40:00 17.7 1.6 21.4 14.1 17.6 1.6 21 13 0.4 0 0.4 0.4 12 5 18 305 2 0 2 0 -0.6 0 0.1 -0.8 10/28/2004 08:50:00 17.2 1.5 20.2 12.2 17.1 1.6 20.2 12.6 0.4 0 0.4 0.4 13 4 14 305 2 0 2 0 -0.6 0 0.1 -0.8 10/28/2004 09:00:00 18 1.5 21.4 13.7 17.8 1.5 21.4 11.8 0.4 0 0.4 0.4 8 5 11 305 2 0 2 0 -0.7 0 -0.1 -1.1 10/28/2004 09:10:00 17.8 1.4 21 13.3 17.7 1.5 21 14.1 0.4 0 0.4 0.4 14 5 20 305 2 0 2 0 -0.8 0.1 0.1 -1.1 10/28/2004 09:20:00 17.3 1.4 19.9 13.7 17.1 1.4 19.9 13.7 0.4 0 0.4 0.4 15 5 15 305 2 0 2 0 -0.7 0.1 -0.1 -1.1 10/28/2004 09:30:00 17.6 1.3 20.6 13 17.5 1.3 20.2 14.1 0.4 0 0.4 0.4 12 4 14 305 1 0 1 0 -0.7 0 -0.1 -1.1 10/28/2004 09:40:00 16.8 1.6 20.6 12.6 16.6 1.7 20.2 12.6 0.4 0 0.4 0.4 12 5 17 305 1 0 1 0 -0.7 0.1 0.1 -1.1 10/28/2004 09:50:00 17.7 1.7 21 12.6 17.7 1.7 21.4 13.3 0.4 0 0.4 0.4 10 4 7 305 1 0 1 0 -0.8 0 -0.1 -1.1 10/28/2004 10:00:00 17.3 1.3 20.6 13.3 17.3 1.4 20.2 13.7 0.4 0 0.4 0.4 13 5 17 305 1 0 1 0 -0.8 0 -0.4 -1.1 10/28/2004 10:10:00 17.8 1.3 21.4 14.1 17.8 1.3 22.1 14.1 0.4 0 0.4 0.4 12 4 7 305 1 0 1 0 -0.8 0 -0.4 -0.8 10/28/2004 10:20:00 17.6 1.2 20.2 14.5 17.5 1.3 20.6 14.1 0.4 0 0.4 0.4 12 5 13 305 1 0 1 0 -0.8 0 -0.4 -1.1 10/28/2004 10:30:00 17.5 1.4 20.6 13.7 17.4 1.4 20.2 13.3 0.4 0 0.4 0.4 11 6 25 305 1 0 1 0 -0.8 0 0.1 -1.1 10/28/2004 10:40:00 17.8 1.4 21 14.1 17.8 1.5 21.4 13.7 0.4 0 0.4 0.4 12 4 12 305 1 0 1 0 -0.9 0 -0.4 -1.1 10/28/2004 10:50:00 17.9 1.7 21.4 13.7 17.8 1.7 21 13 0.4 0 0.4 0.4 12 4 14 305 1 0 1 0 -0.8 0 -0.4 -1.1 10/28/2004 11:00:00 17.4 1.4 20.2 13 17.3 1.5 21 13 0.4 0 0.4 0.4 11 5 7 305 1 0 0 0 -0.8 0.1 -0.1 -1.1 10/28/2004 11:10:00 17.3 1.3 21 13 17.2 1.3 21 13 0.4 0 0.4 0.4 11 5 8 305 1 0 1 0 -0.7 0 -0.1 -0.8 10/28/2004 11:20:00 17.5 1.3 20.2 14.5 17.4 1.3 20.2 14.5 0.4 0 0.4 0.4 11 4 13 305 0 0 0 0 -0.8 0 -0.6 -1.1 10/28/2004 11:30:00 16.9 1.3 20.2 13 16.8 1.4 19.5 13.3 0.4 0 0.4 0.4 9 5 9 305 0 0 0 0 -0.8 0 -0.6 -1.1 10/28/2004 11:40:00 17 1.5 20.6 13.3 17 1.5 20.6 13 0.4 0 0.4 0.4 11 6 11 305 0 0 0 0 -0.8 0 -0.6 -1.1 10/28/2004 11:50:00 16.5 1.6 20.6 12.6 16.6 1.6 20.6 11.8 0.4 0 0.4 0.4 10 5 4 305 0 0 0 0 -0.7 0 -0.6 -0.8 10/28/2004 12:00:00 17.1 1.9 21.4 11.8 17.1 1.9 21.4 11.8 0.4 0 0.4 0.4 7 4 6 305 0 0 0 0 -0.8 0 -0.6 -1.1 10/28/2004 12:10:00 16.9 1.3 19.5 12.2 16.9 1.3 19.9 12.6 0.4 0 0.4 0.4 6 4 4 305 0 0 0 0 -0.8 0 -0.6 -1.1 10/28/2004 12:20:00 16.7 1.2 19.5 13.3 16.8 1.3 19.9 13.3 0.4 0 0.4 0.4 5 6 4 305 0 0 0 0 -0.7 0 -0.6 -0.8 10/28/2004 12:30:00 16.5 1.3 20.2 12.6 16.5 1.3 20.6 12.6 0.4 0 0.4 0.4 10 4 11 305 0 0 0 0 -0.7 0 -0.6 -0.8 10/28/2004 12:40:00 16.4 1.1 19.1 13.3 16.4 1.3 19.1 11.8 0.4 0 0.4 0.4 6 6 359 305 0 0 0 0 -0.7 0 -0.6 -1.1 10/28/2004 12:50:00 15.8 1.9 20.2 11.1 15.9 1.8 20.2 12.2 0.4 0 0.4 0.4 5 5 4 305 0 0 0 0 -0.8 0.1 -0.6 -1.1 10/28/2004 13:00:00 15.7 1.5 18.7 12.2 15.7 1.5 19.1 11.8 0.4 0 0.4 0.4 6 7 9 305 0 0 0 0 -1 0 -0.6 -1.1 10/28/2004 13:10:00 16.1 1.2 18.7 13.3 16.2 1.3 19.1 13 0.4 0 0.4 0.4 8 7 12 305 0 0 0 0 -0.8 0 -0.6 -1.1 10/28/2004 13:20:00 15.4 1.4 18.3 11.8 15.5 1.5 18.7 11.5 0.4 0 0.4 0.4 4 7 1 305 0 0 0 0 -0.9 0.2 -0.6 -1.3 10/28/2004 13:30:00 15.3 1.1 17.2 11.8 15.5 1.2 17.9 11.8 0.4 0 0.4 0.4 2 6 353 305 0 0 0 0 -1 0 -0.6 -1.1 10/28/2004 13:40:00 15.4 1.1 18.3 11.8 15.6 1.2 18.7 12.2 0.4 0 0.4 0.4 354 5 355 305 0 0 0 0 -1.1 0.1 -0.4 -1.3 10/28/2004 13:50:00 15.6 1.5 18.7 11.8 15.9 1.6 19.5 11.5 0.4 0 0.4 0.4 351 5 350 305 0 0 0 0 -1.5 0.1 -0.8 -1.8 10/28/2004 14:00:00 14.6 1.1 17.2 11.1 14.7 1.3 17.6 11.5 0.4 0 0.4 0.4 350 4 349 305 0 0 0 0 -1.5 0.1 -1.1 -1.8 10/28/2004 14:10:00 14.7 1.2 17.6 10.7 14.7 1.3 17.6 10.7 0.4 0 0.4 0.4 352 5 348 305 0 0 0 0 -1.3 0.1 -0.8 -1.5 10/28/2004 14:20:00 15 1.4 18.3 11.1 15.4 1.5 18.7 11.8 0.4 0 0.4 0.4 353 5 357 305 0 0 0 0 -1.5 0.1 -0.8 -1.8 10/28/2004 14:30:00 15.5 1.7 18.7 11.5 15.7 1.9 19.5 10.7 0.4 0 0.4 0.4 353 7 348 305 0 0 0 0 -1.5 0.3 -0.6 -2 10/28/2004 14:40:00 15.5 1.3 17.9 12.2 15.7 1.3 18.3 12.2 0.4 0 0.4 0.4 351 5 348 305 0 0 0 0 -1.9 0.1 -1.3 -2.2 10/28/2004 14:50:00 14.6 1.7 18.7 10.7 14.9 1.8 19.1 10.3 0.4 0 0.4 0.4 353 5 348 305 0 0 0 0 -1.9 0.2 -1.3 -2.4 10/28/2004 15:00:00 15.7 1.3 18.7 11.5 16 1.3 19.1 12.2 0.4 0 0.4 0.4 352 4 351 305 1 0 1 0 -2.4 0.1 -1.8 -2.7 10/28/2004 15:10:00 15.3 1 17.6 11.8 15.6 1.1 18.3 12.2 0.4 0 0.4 0.4 353 5 353 305 1 0 1 0 -2.2 0.1 -1.5 -2.4 10/28/2004 15:20:00 15.5 1.1 17.9 12.2 15.8 1.3 18.7 11.8 0.4 0 0.4 0.4 350 4 351 305 1 0 1 0 -2.2 0 -1.8 -2.4 10/28/2004 15:30:00 15.3 1.3 18.7 11.5 15.5 1.3 19.1 11.8 0.4 0 0.4 0.4 350 4 350 305 1 0 1 0 -2.3 0 -1.8 -2.4 10/28/2004 15:40:00 15.3 1.2 17.6 11.1 15.5 1.3 18.3 11.1 0.4 0 0.4 0.4 350 5 349 305 1 0 1 0 -2.3 0.1 -1.8 -2.7 10/28/2004 15:50:00 15.3 1.1 17.6 12.2 15.6 1.2 17.9 11.8 0.4 0 0.4 0.4 351 5 347 305 1 0 1 0 -2.4 0.2 -1.8 -2.7 10/28/2004 16:00:00 14.5 1.3 17.6 10.3 14.7 1.4 18.3 9.9 0.4 0 0.4 0.4 354 5 357 305 1 0 1 0 -2.6 0 -2.2 -2.7 10/28/2004 16:10:00 14.4 1.3 17.9 10.3 14.6 1.4 17.9 10.3 0.4 0 0.4 0.4 351 5 348 305 1 0 1 0 -2.6 0.2 -2.2 -3.1 10/28/2004 16:20:00 14.1 1 16.1 11.1 14.4 1.1 17.2 11.5 0.4 0 0.4 0.4 351 6 354 305 1 0 1 0 -2.3 0 -2.2 -2.4 10/28/2004 16:30:00 15.3 0.8 17.6 13 15.6 0.8 17.9 13 0.4 0 0.4 0.4 353 4 352 305 1 0 1 0 -2.2 0 -2 -2.4 10/28/2004 16:40:00 15.6 1.1 18.3 11.8 15.9 1.3 18.7 11.5 0.4 0 0.4 0.4 352 4 356 305 1 0 1 0 -2.1 0 -2 -2.4 10/28/2004 16:50:00 15.2 1.1 17.9 11.8 15.5 1.2 18.3 12.2 0.4 0 0.4 0.4 354 5 352 305 1 0 1 0 -2 0 -1.8 -2.2 10/28/2004 17:00:00 16 1.1 18.7 12.6 16.3 1.2 19.1 13 0.4 0 0.4 0.4 351 4 352 305 1 0 1 0 -2.1 0 -2 -2.2 10/28/2004 17:10:00 15.2 1.2 18.7 12.2 15.5 1.3 19.1 12.6 0.4 0 0.4 0.4 351 4 352 305 1 0 1 0 -2.1 0.1 -1.8 -2.2 10/28/2004 17:20:00 15.8 1.1 18.3 12.6 16.1 1.2 19.1 12.6 0.4 0 0.4 0.4 349 4 347 305 1 0 1 0 -2.2 0 -2 -2.4 10/28/2004 17:30:00 16 1.1 18.3 12.6 16.2 1.2 18.7 12.2 0.4 0 0.4 0.4 351 4 337 305 0 0 0 0 -2.2 0 -2 -2.4 10/28/2004 17:40:00 14.9 1.2 17.9 11.5 15.2 1.3 17.6 11.5 0.4 0 0.4 0.4 352 5 350 305 0 0 0 0 -2 0 -1.8 -2.2 10/28/2004 17:50:00 15.1 1.3 17.9 11.5 15.5 1.3 19.1 11.5 0.4 0 0.4 0.4 349 5 348 305 0 0 0 0 -2.1 0 -2 -2.2 10/28/2004 18:00:00 15.1 1.3 18.3 11.5 15.3 1.5 18.7 11.1 0.4 0 0.4 0.4 350 6 345 305 0 0 0 0 -2 0 -1.8 -2.2 10/28/2004 18:10:00 15.3 1 17.9 12.2 15.6 1.1 17.9 12.6 0.4 0 0.4 0.4 348 4 346 305 0 0 0 0 -2.1 0.1 -1.8 -2.2 10/28/2004 18:20:00 15.2 1.5 17.9 11.1 15.5 1.4 18.3 11.5 0.4 0 0.4 0.4 346 4 344 305 0 0 0 0 -2.2 0.1 -1.5 -2.4 10/28/2004 18:30:00 15 1.3 17.9 11.5 15.3 1.3 18.3 12.2 0.4 0 0.4 0.4 349 5 341 305 0 0 0 0 -2.1 0.1 -1.5 -2.2 10/28/2004 18:40:00 15.4 1.3 18.7 11.5 15.7 1.4 18.7 11.5 0.4 0 0.4 0.4 349 5 334 305 0 0 0 0 -2.2 0.1 -1.8 -2.4 10/28/2004 18:50:00 15.6 1.1 18.3 12.2 16 1.3 18.7 11.8 0.4 0 0.4 0.4 347 5 334 305 0 0 0 0 -2.3 0.1 -1.5 -2.4 10/28/2004 19:00:00 15.8 1.2 17.9 12.2 16.1 1.2 18.7 12.6 0.4 0 0.4 0.4 349 4 345 305 0 0 0 0 -2.3 0 -1.8 -2.4 10/28/2004 19:10:00 15.5 1.1 17.9 12.2 15.8 1.1 18.7 12.6 0.4 0 0.4 0.4 351 4 349 305 0 0 0 0 -2.2 0.1 -1.8 -2.4 10/28/2004 19:20:00 16.4 1.2 19.1 12.6 16.8 1.3 19.9 12.6 0.4 0 0.4 0.4 350 5 349 305 0 0 0 0 -2.2 0 -1.8 -2.4 10/28/2004 19:30:00 16.2 1.3 18.7 12.2 16.3 1.4 19.1 13 0.4 0 0.4 0.4 349 5 348 305 0 0 0 0 -2.2 0 -1.8 -2.4 10/28/2004 19:40:00 16.3 1.2 19.1 12.6 16.4 1.4 19.5 12.6 0.4 0 0.4 0.4 349 4 345 305 0 0 0 0 -2.2 0.1 -1.8 -2.4 10/28/2004 19:50:00 15.8 1.2 18.3 11.8 16.2 1.3 19.1 12.6 0.4 0 0.4 0.4 349 4 350 305 0 0 0 0 -2.3 0 -1.8 -2.4 10/28/2004 20:00:00 15.1 1.4 17.9 11.1 15.3 1.4 18.3 11.8 0.4 0 0.4 0.4 348 5 345 305 0 0 0 0 -2.2 0 -1.8 -2.2 10/28/2004 20:10:00 15.7 1.1 18.3 12.6 16 1.2 18.7 12.2 0.4 0 0.4 0.4 347 5 345 305 0 0 0 0 -2.2 0 -1.8 -2.4 10/28/2004 20:20:00 15.6 1.3 18.3 11.5 15.9 1.4 18.7 11.5 0.4 0 0.4 0.4 346 5 346 305 0 0 0 0 -2.2 0 -1.8 -2.4 10/28/2004 20:30:00 16 1.5 19.9 12.2 16.3 1.7 19.5 11.8 0.4 0 0.4 0.4 348 5 346 305 0 0 0 0 -2.3 0 -1.8 -2.4 10/28/2004 20:40:00 16.6 1.2 19.5 13.3 16.9 1.3 20.2 12.6 0.4 0 0.4 0.4 345 4 345 305 0 0 0 0 -2.2 0 -1.8 -2.4 10/28/2004 20:50:00 16.3 1.4 19.1 12.6 16.5 1.5 19.9 11.8 0.4 0 0.4 0.4 348 5 341 305 0 0 0 0 -2.2 0 -1.8 -2.4 10/28/2004 21:00:00 16.3 1.6 20.2 12.6 16.7 1.7 20.2 11.5 0.4 0 0.4 0.4 347 5 348 305 0 0 0 0 -2.3 0 -2 -2.4 10/28/2004 21:10:00 16.6 1.3 19.5 12.6 16.9 1.3 20.2 13.7 0.4 0 0.4 0.4 345 4 340 305 0 0 0 0 -2.5 0 -2.2 -2.7 10/28/2004 21:20:00 16.2 1.5 19.5 11.8 16.4 1.7 19.9 11.8 0.4 0 0.4 0.4 349 5 348 305 0 0 0 0 -2.4 0 -2.2 -2.7 10/28/2004 21:30:00 16.1 1.6 19.5 11.5 16.3 1.7 19.9 11.5 0.4 0 0.4 0.4 346 5 345 305 0 0 0 0 -2.4 0 -2.2 -2.7 10/28/2004 21:40:00 15.9 1.5 20.2 12.2 16.2 1.4 20.2 12.6 0.4 0 0.4 0.4 344 5 342 305 0 0 0 0 -2.4 0 -2.2 -2.7 10/28/2004 21:50:00 15.7 1.2 19.1 12.6 16 1.3 19.9 13 0.4 0 0.4 0.4 341 5 340 305 0 0 0 0 -2.4 0.1 -2.2 -2.7 10/28/2004 22:00:00 15.7 1.3 19.1 11.5 15.9 1.4 19.9 12.2 0.4 0 0.4 0.4 341 7 339 305 0 0 0 0 -2.5 0 -2.2 -2.7 10/28/2004 22:10:00 16.5 1.2 19.9 13 16.7 1.3 19.9 13.3 0.4 0 0.4 0.4 341 4 334 305 0 0 0 0 -2.4 0 -2.2 -2.7 10/28/2004 22:20:00 15.4 1.3 18.7 12.6 15.7 1.3 18.3 11.8 0.4 0 0.4 0.4 343 5 339 305 0 0 0 0 -2.5 0 -2.2 -2.7 10/28/2004 22:30:00 15.4 1.2 18.3 11.8 15.7 1.3 18.7 11.5 0.4 0 0.4 0.4 346 5 349 305 0 0 0 0 -2.4 0 -2.2 -2.7 10/28/2004 22:40:00 15.1 1.2 18.3 11.1 15.4 1.3 18.7 11.5 0.4 0 0.4 0.4 345 6 332 305 0 0 0 0 -2.4 0 -1.8 -2.7 10/28/2004 22:50:00 15.8 1.3 18.3 11.8 16 1.4 19.1 12.6 0.4 0 0.4 0.4 341 5 339 305 0 0 0 0 -2.3 0.1 -1.8 -2.7 10/28/2004 23:00:00 15.8 1.3 18.3 12.6 16.1 1.4 19.1 11.8 0.4 0 0.4 0.4 341 5 336 305 0 0 0 0 -2.5 0 -2 -2.7 10/28/2004 23:10:00 15.7 1.3 19.1 11.8 16 1.3 19.9 12.6 0.4 0 0.4 0.4 346 6 344 305 0 0 0 0 -2.3 0 -1.8 -2.7 10/28/2004 23:20:00 16.3 1.3 19.1 12.2 16.6 1.5 19.9 12.6 0.4 0 0.4 0.4 345 5 353 305 0 0 0 0 -2.4 0.1 -1.8 -2.7 10/28/2004 23:30:00 15.2 1.1 17.9 12.2 15.5 1.1 17.9 12.6 0.4 0 0.4 0.4 346 5 335 305 0 0 0 0 -2.4 0.1 -1.8 -2.7 10/28/2004 23:40:00 15.7 1.6 18.7 11.1 16 1.7 19.5 11.5 0.4 0 0.4 0.4 346 6 345 305 0 0 0 0 -2.3 0.1 -1.8 -2.4 10/28/2004 23:50:00 16 1.1 18.3 13 16.3 1.3 19.5 12.2 0.4 0 0.4 0.4 345 5 346 305 0 0 0 0 -2.4 0 -1.8 -2.7 10/29/2004 00:00:00 14.9 1.4 18.3 11.1 15.1 1.5 18.7 11.5 0.4 0 0.4 0.4 344 6 335 305 0 0 0 0 -2.3 0.1 -1.8 -2.4 10/29/2004 00:10:00 15.8 1.5 19.5 11.8 16.1 1.6 19.5 11.5 0.4 0 0.4 0.4 344 4 345 305 0 0 0 0 -2.3 0 -2 -2.4 10/29/2004 00:20:00 16.2 1.3 19.5 12.2 16.5 1.4 19.5 12.6 0.4 0 0.4 0.4 341 5 340 305 0 0 0 0 -2.4 0 -2 -2.7 10/29/2004 00:30:00 16.5 1.3 20.2 12.6 16.8 1.5 20.2 12.2 0.4 0 0.4 0.4 344 5 337 305 0 0 0 0 -2.4 0 -1.8 -2.7 10/29/2004 00:40:00 16.5 1.6 20.2 13 16.8 1.7 20.2 13 0.4 0 0.4 0.4 345 5 339 305 0 0 0 0 -2.3 0 -1.8 -2.4 10/29/2004 00:50:00 17.1 1.2 19.9 14.1 17.3 1.3 20.6 13.7 0.4 0 0.4 0.4 346 5 337 305 0 0 0 0 -2.4 0 -2 -2.7 10/29/2004 01:00:00 16.5 1.3 19.5 13 16.8 1.5 19.9 13.3 0.4 0 0.4 0.4 345 5 344 305 0 0 0 0 -2.4 0 -2 -2.7 10/29/2004 01:10:00 16.8 1.2 19.5 12.6 17.1 1.4 20.2 13 0.4 0 0.4 0.4 347 5 347 305 0 0 0 0 -2.5 0.1 -2 -2.7 10/29/2004 01:20:00 17.1 1.5 20.2 12.6 17.3 1.5 21 13 0.4 0 0.4 0.4 344 5 331 305 0 0 0 0 -2.4 0.1 -1.8 -2.7 10/29/2004 01:30:00 17.5 1.5 20.6 12.6 17.8 1.6 21.4 11.8 0.4 0 0.4 0.4 343 5 344 305 0 0 0 0 -2.6 0.1 -1.8 -2.7 10/29/2004 01:40:00 17.3 1.3 20.6 13 17.5 1.5 21.4 12.6 0.4 0 0.4 0.4 345 6 338 305 0 0 0 0 -2.7 0 -2.2 -2.9 10/29/2004 01:50:00 17.2 1.3 21 13.7 17.3 1.4 21.4 13.7 0.4 0 0.4 0.4 342 5 340 305 0 0 0 0 -2.8 0 -2.2 -2.9 10/29/2004 02:00:00 17.2 1.3 20.2 13.3 17.5 1.4 20.6 12.6 0.4 0 0.4 0.4 343 5 338 305 0 0 0 0 -2.8 0 -2.2 -2.9 10/29/2004 02:10:00 18 1.2 20.6 13 18.3 1.3 21.8 13.7 0.4 0 0.4 0.4 350 4 353 305 0 0 0 0 -2.8 0 -2.2 -3.1 10/29/2004 02:20:00 17.6 1.4 20.2 13.7 17.8 1.6 21 13.7 0.4 0 0.4 0.4 348 6 358 305 0 0 0 0 -2.8 0 -2.2 -3.1 10/29/2004 02:30:00 16.7 1.1 19.1 13.3 16.8 1.3 19.9 12.6 0.4 0 0.4 0.4 347 5 344 305 0 0 0 0 -2.8 0 -2.2 -2.9 10/29/2004 02:40:00 16.1 1.5 19.9 13 16.3 1.6 20.6 13 0.4 0 0.4 0.4 343 5 344 305 0 0 0 0 -2.8 0 -2 -3.1 10/29/2004 02:50:00 16.6 1.4 19.9 12.6 17 1.5 20.6 12.6 0.4 0 0.4 0.4 347 5 351 305 0 0 0 0 -2.8 0 -2.2 -3.1 10/29/2004 03:00:00 17 1.2 19.9 13.3 17.3 1.5 20.2 12.6 0.4 0 0.4 0.4 343 6 335 305 0 0 0 0 -2.9 0 -2.7 -3.1 10/29/2004 03:10:00 16 1.7 19.9 11.1 16.3 1.8 20.2 11.8 0.4 0 0.4 0.4 343 7 336 305 0 0 0 0 -2.9 0 -2.4 -3.1 10/29/2004 03:20:00 16.6 1.3 19.5 11.8 16.9 1.5 19.9 11.8 0.4 0 0.4 0.4 343 4 345 305 0 0 0 0 -3 0.1 -2.4 -3.3 10/29/2004 03:30:00 16.7 1.6 21 11.8 16.9 1.7 20.6 12.2 0.4 0 0.4 0.4 341 5 337 305 0 0 0 0 -3.1 0.1 -2.4 -3.3 10/29/2004 03:40:00 16.8 1.2 19.9 13.3 17.1 1.3 20.2 13 0.4 0 0.4 0.4 341 5 342 305 0 0 0 0 -3.1 0.1 -2.4 -3.3 10/29/2004 03:50:00 16.2 1.3 19.5 12.6 16.6 1.4 19.9 13 0.4 0 0.4 0.4 345 6 341 305 0 0 0 0 -3.1 0.1 -2.4 -3.3 10/29/2004 04:00:00 16.8 1.4 19.9 13.3 17 1.5 21 12.2 0.4 0 0.4 0.4 343 6 348 305 0 0 0 0 -3 0 -2.4 -3.3 10/29/2004 04:10:00 17.9 1.3 20.6 14.5 18.2 1.5 21.8 13.7 0.4 0 0.4 0.4 343 5 344 305 0 0 0 0 -3.1 0 -2.7 -3.3 10/29/2004 04:20:00 18.1 1.7 21 12.6 18.3 1.8 22.1 13 0.4 0 0.4 0.4 342 5 344 305 0 0 0 0 -3.2 0 -2.7 -3.3 10/29/2004 04:30:00 17.9 1.5 21.8 13.7 18.1 1.7 22.6 13.7 0.4 0 0.4 0.4 342 5 346 305 0 0 0 0 -3.2 0 -2.7 -3.3 10/29/2004 04:40:00 17.8 1.7 20.6 11.8 18 1.7 21.4 13 0.4 0 0.4 0.4 343 5 340 305 0 0 0 0 -3.2 0.1 -2.7 -3.3 10/29/2004 04:50:00 18.2 1.4 21.4 13.7 18.4 1.5 21.8 13.7 0.4 0 0.4 0.4 342 5 340 305 0 0 0 0 -3.3 0 -2.7 -3.6 10/29/2004 05:00:00 17.8 1.7 21.4 13 17.9 1.9 22.1 13.3 0.4 0 0.4 0.4 341 5 338 305 0 0 0 0 -3.2 0.1 -2.4 -3.3 10/29/2004 05:10:00 17.8 1.6 21 13.7 17.8 1.7 21.4 12.2 0.4 0 0.4 0.4 337 5 336 305 0 0 0 0 -3.2 0.1 -2.4 -3.3 10/29/2004 05:20:00 18 1.3 21 14.5 18.2 1.5 22.1 13.7 0.4 0 0.4 0.4 341 5 338 305 0 0 0 0 -3.3 0 -2.7 -3.6 10/29/2004 05:30:00 16.7 1.6 21 12.2 17 1.6 21.4 12.6 0.4 0 0.4 0.4 344 6 345 305 0 0 0 0 -3.3 0 -2.9 -3.6 10/29/2004 05:40:00 17.5 1.7 21.8 13 17.6 1.9 21.8 13.3 0.4 0 0.4 0.4 341 7 335 305 0 0 0 0 -3.3 0 -3.1 -3.6 10/29/2004 05:50:00 18.4 1.4 22.9 14.1 18.5 1.6 22.9 14.5 0.4 0 0.4 0.4 343 6 343 305 0 0 0 0 -3.5 0 -3.3 -3.8 10/29/2004 06:00:00 18.4 1.6 21.8 14.1 18.4 1.7 22.1 13.3 0.4 0 0.4 0.4 339 5 348 305 0 0 0 0 -3.5 0 -3.1 -3.8 10/29/2004 06:10:00 18.6 2 22.1 13 18.7 2.1 22.9 13 0.4 0 0.4 0.4 339 5 337 305 0 0 0 0 -3.4 0 -3.1 -3.6 10/29/2004 06:20:00 18.4 1.6 22.1 13.3 18.6 1.7 22.6 13.7 0.4 0 0.4 0.4 341 5 337 305 0 0 0 0 -3.4 0 -3.1 -3.8 10/29/2004 06:30:00 19.4 1.5 23.7 14.9 19.6 1.6 22.9 15.3 0.4 0 0.4 0.4 343 5 355 305 0 0 0 0 -3.4 0 -3.3 -3.6 10/29/2004 06:40:00 18.8 1.7 22.1 12.6 18.8 1.8 22.9 13 0.4 0 0.4 0.4 341 5 350 305 0 0 0 0 -3.5 0 -3.3 -3.8 10/29/2004 06:50:00 19.4 1.6 22.9 14.1 19.5 1.7 23.7 13.3 0.4 0 0.4 0.4 345 5 353 305 0 0 0 0 -3.6 0.1 -3.3 -3.8 10/29/2004 07:00:00 18.3 1.5 22.1 14.5 18.5 1.7 22.9 14.1 0.4 0 0.4 0.4 344 6 344 305 0 0 0 0 -3.5 0.1 -3.3 -3.8 10/29/2004 07:10:00 19.5 1.9 22.9 13.7 19.6 2 23.7 13 0.4 0 0.4 0.4 339 5 336 305 0 0 0 0 -3.6 0.1 -3.3 -3.8 10/29/2004 07:20:00 18.5 1.5 22.6 14.5 18.7 1.7 23.3 14.1 0.4 0 0.4 0.4 347 4 346 305 0 0 0 0 -3.5 0 -3.3 -3.8 10/29/2004 07:30:00 17.1 1.7 22.1 13 17.3 1.7 22.1 13 0.4 0 0.4 0.4 343 6 349 305 0 0 0 0 -3.4 0.2 -3.1 -3.8 10/29/2004 07:40:00 18.4 1.5 22.1 13.7 18.5 1.6 22.9 13.7 0.4 0 0.4 0.4 343 5 340 305 0 0 0 0 -3.6 0.1 -3.3 -3.8 10/29/2004 07:50:00 18.4 1.8 22.9 13 18.6 1.9 22.9 12.6 0.4 0 0.4 0.4 344 5 341 305 0 0 0 0 -3.7 0.1 -3.1 -3.8 10/29/2004 08:00:00 18.4 1.8 22.6 14.1 18.6 1.9 22.6 13.7 0.4 0 0.4 0.4 345 5 343 305 0 0 0 0 -3.9 0 -3.3 -4 10/29/2004 08:10:00 17.7 1.7 21.4 13.3 17.7 1.8 22.1 13.3 0.4 0 0.4 0.4 340 6 333 305 0 0 0 0 -3.7 0.1 -3.1 -4 10/29/2004 08:20:00 18.3 1.8 22.6 13 18.3 1.8 21.8 12.6 0.4 0 0.4 0.4 340 5 339 305 0 0 0 0 -3.9 0 -3.3 -4 10/29/2004 08:30:00 18.4 1.5 21.8 14.1 18.5 1.5 22.1 13.7 0.4 0 0.4 0.4 342 5 344 305 0 0 0 0 -3.9 0.1 -3.1 -4 10/29/2004 08:40:00 17.7 1.9 21.8 12.2 17.6 2.1 22.6 12.2 0.4 0 0.4 0.4 340 5 343 305 0 0 0 0 -3.9 0 -3.6 -4 10/29/2004 08:50:00 17.1 2.1 22.9 12.6 17.1 2.2 22.1 12.2 0.4 0 0.4 0.4 341 5 333 305 0 0 0 0 -3.7 0.1 -3.1 -4 10/29/2004 09:00:00 17.8 1.9 22.1 12.2 18 2 22.6 11.8 0.4 0 0.4 0.4 341 5 340 305 0 0 0 0 -3.9 0 -3.3 -4 10/29/2004 09:10:00 17.1 1.4 20.2 13 17.2 1.6 20.6 12.6 0.4 0 0.4 0.4 341 5 336 305 0 0 0 0 -3.9 0.1 -3.1 -4 10/29/2004 09:20:00 16.8 1.7 20.6 13 16.7 1.8 21.4 12.2 0.4 0 0.4 0.4 338 7 333 305 0 0 0 0 -4 0.2 -3.3 -4.5 10/29/2004 09:30:00 16 1.3 19.1 12.2 16.1 1.5 19.5 11.8 0.4 0 0.4 0.4 336 6 337 305 0 0 0 0 -4 0 -3.6 -4.2 10/29/2004 09:40:00 16 1.5 19.9 12.6 15.9 1.6 19.9 11.8 0.4 0 0.4 0.4 337 6 336 305 0 0 0 0 -4.1 0.1 -3.3 -4.5 10/29/2004 09:50:00 15.9 1.2 18.7 12.2 16.1 1.3 19.5 12.2 0.4 0 0.4 0.4 338 5 330 305 0 0 0 0 -4.1 0.1 -3.6 -4.2 10/29/2004 10:00:00 16.7 1.2 20.2 13 16.6 1.4 20.6 13 0.4 0 0.4 0.4 335 5 340 305 0 0 0 0 -4 0 -3.6 -4.2 10/29/2004 10:10:00 17.6 1.7 21.4 13.3 17.6 1.8 21.4 13 0.4 0 0.4 0.4 336 6 331 305 0 0 0 0 -4 0.1 -3.6 -4.5 10/29/2004 10:20:00 16.6 1.5 19.9 12.2 16.4 1.6 19.9 12.2 0.4 0 0.4 0.4 334 8 334 305 0 0 0 0 -3.9 0 -3.3 -4.2 10/29/2004 10:30:00 17.5 1.7 21 13 17.5 1.8 20.6 12.2 0.4 0 0.4 0.4 337 5 337 305 0 0 0 0 -3.9 0 -3.3 -4 10/29/2004 10:40:00 16.4 1.9 21 11.5 16.4 2 21 11.5 0.4 0 0.4 0.4 338 5 336 305 0 0 0 0 -3.9 0 -3.8 -4 10/29/2004 10:50:00 16.9 1.5 20.2 11.8 16.9 1.5 20.2 11.1 0.4 0 0.4 0.4 339 6 337 305 0 0 0 0 -3.9 0 -3.6 -4 10/29/2004 11:00:00 17.1 1.3 19.9 13 17.2 1.4 19.9 11.8 0.4 0 0.4 0.4 339 6 334 305 0 0 0 0 -3.9 0 -3.8 -4 10/29/2004 11:10:00 16.9 1.5 20.6 13 16.8 1.5 20.2 13 0.4 0 0.4 0.4 340 6 345 305 0 0 0 0 -4 0 -3.8 -4 10/29/2004 11:20:00 16.5 1.3 19.9 13 16.7 1.4 20.2 13 0.4 0 0.4 0.4 343 5 348 305 0 0 0 0 -3.9 0 -3.8 -4 10/29/2004 11:30:00 16.4 1.4 19.5 13 16.6 1.4 19.9 13.3 0.4 0 0.4 0.4 341 5 339 305 0 0 0 0 -4 0 -3.8 -4.2 10/29/2004 11:40:00 16.7 1.3 19.5 13.7 16.8 1.3 19.5 13.3 0.4 0 0.4 0.4 342 5 337 305 0 0 0 0 -4 0 -3.8 -4.2 10/29/2004 11:50:00 16.5 1.5 20.2 13 16.5 1.5 20.2 13 0.4 0 0.4 0.4 339 5 339 305 0 0 0 0 -4.1 0.1 -3.8 -4.5 10/29/2004 12:00:00 16.6 1.3 19.9 12.6 16.6 1.4 19.5 12.2 0.4 0 0.4 0.4 340 5 335 305 0 0 0 0 -4.2 0 -4 -4.5 10/29/2004 12:10:00 16.8 1.3 19.9 12.6 16.8 1.4 19.9 12.6 0.4 0 0.4 0.4 342 5 343 305 0 0 0 0 -4.2 0 -4 -4.5 10/29/2004 12:20:00 16.3 1.5 20.2 12.6 16.3 1.5 19.9 12.6 0.4 0 0.4 0.4 342 5 331 305 0 0 0 0 -4 0 -3.3 -4.2 10/29/2004 12:30:00 16.2 1.4 19.1 12.2 16.3 1.5 19.9 11.8 0.4 0 0.4 0.4 339 6 342 305 0 0 0 0 -4 0 -3.3 -4.2 10/29/2004 12:40:00 16.4 1.5 19.9 12.2 16.5 1.5 19.9 12.6 0.4 0 0.4 0.4 340 5 341 305 0 0 0 0 -4.1 0 -3.6 -4.5 10/29/2004 12:50:00 16.3 1.3 19.5 13 16.4 1.3 19.5 13 0.4 0 0.4 0.4 340 5 346 305 0 0 0 0 -4 0.1 -3.3 -4.2 10/29/2004 13:00:00 16.5 1.4 19.9 13 16.6 1.5 20.2 12.2 0.4 0 0.4 0.4 340 6 337 305 0 0 0 0 -4.1 0 -3.6 -4.5 10/29/2004 13:10:00 16 1.3 19.5 13 16.1 1.5 19.9 12.6 0.4 0 0.4 0.4 340 6 336 305 0 0 0 0 -4 0.1 -3.3 -4.2 10/29/2004 13:20:00 16.5 1.2 19.9 13 16.5 1.3 19.9 13 0.4 0 0.4 0.4 341 6 339 305 0 0 0 0 -4.1 0 -3.6 -4.5 10/29/2004 13:30:00 16.4 1.5 19.5 11.5 16.5 1.5 19.5 12.2 0.4 0 0.4 0.4 340 5 336 305 0 0 0 0 -4 0.2 -3.1 -4.2 10/29/2004 13:40:00 15.5 1.6 20.2 11.5 15.6 1.6 20.2 11.1 0.4 0 0.4 0.4 338 5 340 305 0 0 0 0 -4 0 -3.3 -4.2 10/29/2004 13:50:00 15.6 1.2 18.3 12.2 15.7 1.2 18.3 11.8 0.4 0 0.4 0.4 342 6 332 305 0 0 0 0 -4.1 0.1 -3.6 -4.5 10/29/2004 14:00:00 15.4 1.5 18.3 11.5 15.5 1.6 18.7 11.8 0.4 0 0.4 0.4 342 5 337 305 0 0 0 0 -4.2 0.1 -3.3 -4.5 10/29/2004 14:10:00 15.6 1.5 19.1 11.8 15.8 1.7 20.2 11.8 0.4 0 0.4 0.4 345 5 350 305 0 0 0 0 -4.2 0.1 -3.6 -4.5 10/29/2004 14:20:00 16.1 1.4 20.2 12.6 16.2 1.5 20.2 12.2 0.4 0 0.4 0.4 346 5 348 305 0 0 0 0 -4.2 0.1 -3.6 -4.5 10/29/2004 14:30:00 16.4 1.6 19.9 11.8 16.6 1.7 21.8 11.8 0.4 0 0.4 0.4 345 5 351 305 0 0 0 0 -4.2 0.1 -3.8 -4.5 10/29/2004 14:40:00 16.2 1.5 19.9 11.5 16.4 1.5 20.2 11.8 0.4 0 0.4 0.4 344 5 340 305 0 0 0 0 -4.2 0 -4 -4.5 10/29/2004 14:50:00 16.2 1.5 19.9 12.2 16.4 1.5 19.9 11.8 0.4 0 0.4 0.4 346 6 341 305 0 0 0 0 -4.2 0 -4 -4.5 10/29/2004 15:00:00 16.2 1.3 19.5 12.6 16.4 1.3 19.9 12.2 0.4 0 0.4 0.4 346 5 345 305 0 0 0 0 -4.2 0.1 -4 -4.5 10/29/2004 15:10:00 16.5 1.5 19.5 12.6 16.6 1.5 20.2 12.6 0.4 0 0.4 0.4 343 5 344 305 0 0 0 0 -4.2 0 -4 -4.5 10/29/2004 15:20:00 16.1 1.5 20.2 12.6 16.2 1.5 20.2 13 0.4 0 0.4 0.4 347 4 346 305 0 0 0 0 -4.1 0.1 -3.8 -4.5 10/29/2004 15:30:00 16.1 1.1 18.7 13 16.3 1.1 19.1 13 0.4 0 0.4 0.4 346 4 351 305 0 0 0 0 -4.3 0 -4 -4.5 10/29/2004 15:40:00 15.8 1.5 19.1 11.8 16 1.5 19.1 11.8 0.4 0 0.4 0.4 344 6 338 305 0 0 0 0 -4.2 0 -4 -4.5 10/29/2004 15:50:00 16 1.2 19.1 12.2 16.3 1.3 19.1 11.8 0.4 0 0.4 0.4 346 5 330 305 0 0 0 0 -4.4 0 -4.2 -4.7 10/29/2004 16:00:00 16.8 1 19.1 13.3 17 1.1 19.5 13 0.4 0 0.4 0.4 349 6 343 305 0 0 0 0 -4.4 0 -4 -4.7 10/29/2004 16:10:00 16.6 1.4 19.1 12.6 16.7 1.5 19.9 11.8 0.4 0 0.4 0.4 352 5 350 305 0 0 0 0 -4.2 0.2 -3.8 -4.7 10/29/2004 16:20:00 16.9 1.1 19.5 13.3 17 1.3 20.2 13 0.4 0 0.4 0.4 352 4 356 305 0 0 0 0 -4.4 0.1 -4 -4.7 10/29/2004 16:30:00 16.7 1.3 19.5 12.6 16.9 1.5 20.2 12.6 0.4 0 0.4 0.4 353 4 354 305 0 0 0 0 -4.4 0 -4 -4.7 10/29/2004 16:40:00 16.3 1.1 18.3 13 16.6 1.1 19.1 13 0.4 0 0.4 0.4 351 4 343 305 0 0 0 0 -4.6 0 -4.2 -4.7 10/29/2004 16:50:00 15.7 1.4 18.7 12.2 15.9 1.5 19.1 11.5 0.4 0 0.4 0.4 348 5 343 305 0 0 0 0 -4.5 0 -4 -4.7 10/29/2004 17:00:00 16.1 1.3 18.7 11.8 16.1 1.4 18.7 12.2 0.4 0 0.4 0.4 348 5 350 305 0 0 0 0 -4.5 0 -4 -4.7 10/29/2004 17:10:00 15.4 1.3 18.3 12.2 15.7 1.3 18.7 12.6 0.4 0 0.4 0.4 349 6 346 305 0 0 0 0 -4.6 0.2 -4 -4.9 10/29/2004 17:20:00 15.4 1.3 18.7 12.2 15.7 1.5 19.1 11.1 0.4 0 0.4 0.4 350 6 350 305 0 0 0 0 -4.7 0.1 -4.5 -4.9 10/29/2004 17:30:00 15.4 1 17.2 12.2 15.7 1.1 17.9 11.8 0.4 0 0.4 0.4 352 5 350 305 0 0 0 0 -4.8 0.1 -4.5 -4.9 10/29/2004 17:40:00 15 1.6 18.3 10.7 15.2 1.6 18.3 10.7 0.4 0 0.4 0.4 349 6 340 305 0 0 0 0 -4.6 0 -4.5 -4.7 10/29/2004 17:50:00 15.9 1.1 18.3 12.6 16.3 1.2 19.1 12.6 0.4 0 0.4 0.4 351 5 348 305 0 0 0 0 -4.9 0.1 -4 -5.1 10/29/2004 18:00:00 14.7 1.1 17.6 11.5 15.1 1.1 17.6 12.2 0.4 0 0.4 0.4 350 7 343 305 0 0 0 0 -4.8 0.1 -4.2 -4.9 10/29/2004 18:10:00 15.8 1.2 19.1 11.5 15.9 1.3 18.7 11.8 0.4 0 0.4 0.4 349 6 352 305 0 0 0 0 -4.9 0 -4.5 -5.1 10/29/2004 18:20:00 15.6 1.1 17.6 12.2 15.8 1.2 17.9 12.6 0.4 0 0.4 0.4 351 6 355 305 0 0 0 0 -4.9 0 -4.5 -5.1 10/29/2004 18:30:00 15.7 1.2 19.1 13 16 1.3 19.9 13 0.4 0 0.4 0.4 350 5 345 305 0 0 0 0 -5 0 -4.5 -5.3 10/29/2004 18:40:00 15.5 1.1 17.6 12.2 15.7 1.2 17.9 12.6 0.4 0 0.4 0.4 353 5 350 305 0 0 0 0 -5.1 0 -4.5 -5.3 10/29/2004 18:50:00 14.7 1.3 17.6 11.1 14.9 1.5 17.6 10.7 0.4 0 0.4 0.4 350 5 342 305 0 0 0 0 -5 0 -4.7 -5.1 10/29/2004 19:00:00 15.5 1.3 18.7 12.2 15.8 1.3 19.9 12.6 0.4 0 0.4 0.4 349 6 347 305 0 0 0 0 -5.1 0 -4.7 -5.3 10/29/2004 19:10:00 15.1 1.1 18.7 12.2 15.4 1.2 19.1 12.2 0.4 0 0.4 0.4 352 5 347 305 0 0 0 0 -5.1 0 -4.7 -5.3 10/29/2004 19:20:00 14.7 1.3 17.6 10.3 15 1.3 17.9 11.1 0.4 0 0.4 0.4 350 5 350 305 0 0 0 0 -5.1 0 -4.9 -5.3 10/29/2004 19:30:00 14.8 1.3 17.6 11.1 15.1 1.3 18.7 11.5 0.4 0 0.4 0.4 349 6 342 305 0 0 0 0 -5.2 0.1 -4.9 -5.6 10/29/2004 19:40:00 14.6 1.2 17.2 11.1 14.8 1.3 17.6 10.7 0.4 0 0.4 0.4 347 5 344 305 0 0 0 0 -5.1 0 -4.7 -5.3 10/29/2004 19:50:00 14.5 1.4 19.1 10.7 14.7 1.4 18.3 10.7 0.4 0 0.4 0.4 347 6 338 305 0 0 0 0 -5 0 -4.7 -5.1 10/29/2004 20:00:00 14.8 1.2 17.2 11.8 15.1 1.3 17.6 11.5 0.4 0 0.4 0.4 346 5 349 305 0 0 0 0 -5 0 -4.7 -5.3 10/29/2004 20:10:00 14.9 1.2 17.2 11.1 15.1 1.3 17.9 11.1 0.4 0 0.4 0.4 349 5 352 305 0 0 0 0 -5 0 -4.9 -5.3 10/29/2004 20:20:00 14.5 1.1 17.2 11.8 14.9 1.1 17.9 11.8 0.4 0 0.4 0.4 349 6 350 305 0 0 0 0 -5.1 0 -4.7 -5.3 10/29/2004 20:30:00 14.4 1.3 17.9 10.3 14.7 1.3 17.9 11.1 0.4 0 0.4 0.4 348 6 342 305 0 0 0 0 -4.9 0 -4.7 -5.1 10/29/2004 20:40:00 14.6 1.2 17.9 11.5 14.9 1.2 18.3 11.5 0.4 0 0.4 0.4 347 5 348 305 0 0 0 0 -5 0 -4.7 -5.1 10/29/2004 20:50:00 14.4 1.3 17.6 11.1 14.6 1.5 17.6 11.1 0.4 0 0.4 0.4 354 5 2 305 0 0 0 0 -5 0 -4.7 -5.1 10/29/2004 21:00:00 15 0.9 16.8 12.2 15.2 1 17.2 12.6 0.4 0 0.4 0.4 355 4 357 305 0 0 0 0 -5 0 -4.7 -5.1 10/29/2004 21:10:00 14.6 1.1 16.8 10.3 14.8 1.1 17.2 11.1 0.4 0 0.4 0.4 352 6 357 305 0 0 0 0 -5 0 -4.7 -5.1 10/29/2004 21:20:00 14.7 1.1 17.6 11.5 14.9 1.1 17.9 10.7 0.4 0 0.4 0.4 352 5 345 305 0 0 0 0 -4.9 0 -4.7 -5.1 10/29/2004 21:30:00 14.2 1.2 17.6 10.7 14.5 1.3 17.2 11.1 0.4 0 0.4 0.4 350 5 351 305 0 0 0 0 -5 0 -4.5 -5.1 10/29/2004 21:40:00 13.6 1.1 16.1 10.7 13.7 1.2 16.8 10.7 0.4 0 0.4 0.4 347 7 350 305 0 0 0 0 -4.8 0.1 -4.5 -5.1 10/29/2004 21:50:00 13.8 1.3 16.4 9.5 14.1 1.4 17.2 9.1 0.4 0 0.4 0.4 352 4 1 305 0 0 0 0 -4.9 0.1 -4.5 -5.1 10/29/2004 22:00:00 13.8 1.2 16.4 10.7 14 1.3 17.2 9.9 0.4 0 0.4 0.4 349 5 357 305 0 0 0 0 -4.9 0 -4.7 -5.1 10/29/2004 22:10:00 14.1 1.1 17.2 11.5 14.3 1.2 17.6 11.5 0.4 0 0.4 0.4 349 5 350 305 0 0 0 0 -5 0 -4.7 -5.1 10/29/2004 22:20:00 13.8 1.1 16.4 10.7 14 1.2 16.8 10.7 0.4 0 0.4 0.4 351 5 355 305 0 0 0 0 -4.9 0 -4.5 -4.9 10/29/2004 22:30:00 14.2 1 16.4 10.7 14.5 1.1 16.8 10.7 0.4 0 0.4 0.4 352 6 351 305 0 0 0 0 -4.8 0 -4.5 -4.9 10/29/2004 22:40:00 14 1.1 16.8 11.1 14.3 1.1 16.4 11.1 0.4 0 0.4 0.4 356 4 359 305 0 0 0 0 -4.8 0 -4.5 -4.9 10/29/2004 22:50:00 13.4 1.2 16.4 9.9 13.7 1.3 16.8 9.5 0.4 0 0.4 0.4 350 4 351 305 0 0 0 0 -4.6 0 -4 -4.7 10/29/2004 23:00:00 13.8 1.2 16.8 10.7 14 1.3 17.2 11.1 0.4 0 0.4 0.4 352 5 350 305 0 0 0 0 -4.6 0 -4.5 -4.7 10/29/2004 23:10:00 14.1 1.1 16.4 11.1 14.4 1.2 17.2 10.7 0.4 0 0.4 0.4 355 5 350 305 0 0 0 0 -4.6 0 -4.2 -4.9 10/29/2004 23:20:00 13.2 1.1 15.3 9.9 13.5 1.2 16.1 9.9 0.4 0 0.4 0.4 357 5 356 305 0 0 0 0 -4.6 0 -4 -4.9 10/29/2004 23:30:00 13.3 1.3 16.8 9.1 13.6 1.4 16.8 9.1 0.4 0 0.4 0.4 353 5 344 305 0 0 0 0 -4.5 0.1 -3.8 -4.7 10/29/2004 23:40:00 13.1 1 15.3 9.9 13.3 1.1 16.1 9.9 0.4 0 0.4 0.4 352 4 353 305 0 0 0 0 -4.6 0 -4.2 -4.7 10/29/2004 23:50:00 13.3 1 16.1 10.7 13.5 1.1 16.4 10.3 0.4 0 0.4 0.4 354 5 354 305 0 0 0 0 -4.7 0 -4.5 -4.7 10/30/2004 00:00:00 13.4 1 16.1 10.7 13.5 1.1 16.4 10.3 0.4 0 0.4 0.4 357 5 359 305 0 0 0 0 -4.5 0 -4 -4.7 10/30/2004 00:10:00 12.7 1.2 15.6 7.6 13 1.2 16.1 8.8 0.4 0 0.4 0.4 353 6 359 305 0 0 0 0 -4.5 0 -4.2 -4.7 10/30/2004 00:20:00 12.8 1 14.9 9.9 13.1 1 16.1 10.3 0.4 0 0.4 0.4 352 5 354 305 0 0 0 0 -4.5 0 -4.2 -4.7 10/30/2004 00:30:00 13.2 1.1 16.1 9.9 13.5 1.2 16.4 10.3 0.4 0 0.4 0.4 356 5 357 305 0 0 0 0 -4.5 0 -4.2 -4.7 10/30/2004 00:40:00 13.1 1.1 15.6 9.9 13.4 1.2 16.1 9.1 0.4 0 0.4 0.4 356 5 358 305 0 0 0 0 -4.5 0 -4.2 -4.7 10/30/2004 00:50:00 13.2 1 16.1 9.1 13.4 1 16.1 10.3 0.4 0 0.4 0.4 354 4 353 305 0 0 0 0 -4.5 0 -4.5 -4.7 10/30/2004 01:00:00 13.5 1.1 16.1 9.9 13.8 1.2 16.4 10.3 0.4 0 0.4 0.4 359 5 0 305 0 0 0 0 -4.5 0 -4.2 -4.7 10/30/2004 01:10:00 13 1 15.3 10.3 13.2 1.2 16.4 10.3 0.4 0 0.4 0.4 354 6 351 305 0 0 0 0 -4.5 0 -4 -4.7 10/30/2004 01:20:00 12.9 1 15.3 10.7 13.3 1 15.6 10.7 0.4 0 0.4 0.4 357 6 357 305 0 0 0 0 -4.5 0 -4.5 -4.7 10/30/2004 01:30:00 12.8 1.3 16.4 9.5 13 1.3 16.4 9.9 0.4 0 0.4 0.4 0 5 7 305 0 0 0 0 -4.4 0 -4.2 -4.7 10/30/2004 01:40:00 12.8 1.1 15.3 9.5 13.1 1.1 16.1 9.9 0.4 0 0.4 0.4 358 4 0 305 0 0 0 0 -4.5 0 -4.5 -4.7 10/30/2004 01:50:00 13.3 1 16.1 10.3 13.6 1 16.1 10.3 0.4 0 0.4 0.4 359 5 1 305 0 0 0 0 -4.5 0 -4.2 -4.7 10/30/2004 02:00:00 13.3 1.1 15.6 9.5 13.6 1.2 15.6 9.5 0.4 0 0.4 0.4 358 4 354 305 0 0 0 0 -4.4 0 -4 -4.5 10/30/2004 02:10:00 13 0.9 16.1 10.7 13.2 1 16.8 10.7 0.4 0 0.4 0.4 354 6 358 305 0 0 0 0 -4.4 0 -4.2 -4.7 10/30/2004 02:20:00 13.3 0.9 16.1 11.1 13.6 1 16.1 10.3 0.4 0 0.4 0.4 353 5 355 305 0 0 0 0 -4.5 0 -4.2 -4.7 10/30/2004 02:30:00 12 1.2 15.3 9.1 12.2 1.2 15.3 8.8 0.4 0 0.4 0.4 358 5 353 305 0 0 0 0 -4.6 0 -4.2 -4.7 10/30/2004 02:40:00 12.5 1 15.3 9.9 12.8 1 14.9 9.5 0.4 0 0.4 0.4 356 5 9 305 0 0 0 0 -4.7 0 -4.5 -4.9 10/30/2004 02:50:00 11.9 1.3 14.5 8.4 12.1 1.3 14.9 8.4 0.4 0 0.4 0.4 355 5 359 305 0 0 0 0 -4.6 0 -4.2 -4.7 10/30/2004 03:00:00 12.4 0.9 14.5 10.3 12.7 1 14.9 10.7 0.4 0 0.4 0.4 353 6 350 305 0 0 0 0 -4.6 0 -4.2 -4.7 10/30/2004 03:10:00 11.8 1.2 14.1 8 12 1.2 14.5 8.8 0.4 0 0.4 0.4 354 4 351 305 0 0 0 0 -4.7 0 -4.5 -4.9 10/30/2004 03:20:00 12.4 1.2 15.3 9.5 12.7 1.3 15.6 9.5 0.4 0 0.4 0.4 354 5 342 305 0 0 0 0 -4.7 0.1 -4.2 -4.9 10/30/2004 03:30:00 11.7 1.2 14.9 8.8 12.1 1.2 15.3 8.8 0.4 0 0.4 0.4 354 5 353 305 0 0 0 0 -4.8 0 -4.5 -5.1 10/30/2004 03:40:00 11.4 0.9 13.3 8.8 11.7 0.9 13.7 8.8 0.4 0 0.4 0.4 354 6 359 305 0 0 0 0 -4.8 0 -4.5 -4.9 10/30/2004 03:50:00 11.4 1 14.5 8.8 11.6 1.1 15.6 8.8 0.4 0 0.4 0.4 351 6 348 305 0 0 0 0 -4.9 0 -4.5 -4.9 10/30/2004 04:00:00 11.2 1.1 15.3 8 11.5 1.2 14.9 8.8 0.4 0 0.4 0.4 352 7 353 305 0 0 0 0 -4.9 0 -4.7 -5.1 10/30/2004 04:10:00 10.8 0.9 13 8.4 11.1 1 13.3 8.4 0.4 0 0.4 0.4 355 8 358 305 0 0 0 0 -5 0 -4.9 -5.1 10/30/2004 04:20:00 10.9 1.1 13.3 8 11.3 1.1 14.1 8 0.4 0 0.4 0.4 349 4 347 305 0 0 0 0 -5.2 0 -4.9 -5.3 10/30/2004 04:30:00 10.4 1.1 12.6 7.6 10.7 1.1 13.3 7.6 0.4 0 0.4 0.4 356 5 2 305 0 0 0 0 -5.2 0 -4.9 -5.3 10/30/2004 04:40:00 10 0.9 12.2 7.2 10.2 1 12.6 7.6 0.4 0 0.4 0.4 359 5 0 305 0 0 0 0 -5.2 0 -5.1 -5.6 10/30/2004 04:50:00 10.1 1 12.2 7.2 10.3 1 12.6 7.6 0.4 0 0.4 0.4 353 5 356 305 0 0 0 0 -5.3 0 -5.1 -5.6 10/30/2004 05:00:00 9.8 0.8 12.6 7.6 10.1 0.8 12.6 8.4 0.4 0 0.4 0.4 354 6 353 305 0 0 0 0 -5.2 0 -5.1 -5.6 10/30/2004 05:10:00 9.5 0.9 11.8 6.8 9.7 1 12.6 6.8 0.4 0 0.4 0.4 359 5 350 305 0 0 0 0 -5.3 0.1 -5.1 -5.6 10/30/2004 05:20:00 9.3 0.8 11.8 7.2 9.6 1 12.6 7.2 0.4 0 0.4 0.4 354 6 358 305 0 0 0 0 -5.3 0 -5.1 -5.6 10/30/2004 05:30:00 8.7 0.7 10.3 6.5 9 0.8 10.7 6.8 0.4 0 0.4 0.4 355 7 0 305 0 0 0 0 -5.3 0 -5.1 -5.6 10/30/2004 05:40:00 9.1 0.9 11.5 7.2 9.3 0.9 11.5 7.2 0.4 0 0.4 0.4 357 5 354 305 0 0 0 0 -5.3 0.1 -5.1 -5.6 10/30/2004 05:50:00 8.6 0.8 10.7 6.5 8.8 0.8 11.1 6.8 0.4 0 0.4 0.4 358 7 2 305 0 0 0 0 -5.5 0 -5.3 -5.6 10/30/2004 06:00:00 8.7 0.8 10.7 7.2 9 0.8 11.1 7.2 0.4 0 0.4 0.4 357 7 352 305 0 0 0 0 -5.5 0 -5.3 -5.6 10/30/2004 06:10:00 8.4 0.8 10.3 6.5 8.6 0.9 10.7 6.1 0.4 0 0.4 0.4 1 6 4 305 0 0 0 0 -5.5 0 -5.3 -5.6 10/30/2004 06:20:00 8.3 0.8 9.9 6.1 8.5 0.8 9.9 6.5 0.4 0 0.4 0.4 3 5 7 305 0 0 0 0 -5.5 0 -5.1 -5.6 10/30/2004 06:30:00 8.1 0.8 10.3 5.7 8.3 0.9 11.1 5.7 0.4 0 0.4 0.4 4 7 14 305 0 0 0 0 -5.4 0 -5.1 -5.6 10/30/2004 06:40:00 7.7 0.6 9.9 6.1 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 7 5 5 305 0 0 0 0 -5.5 0 -5.1 -5.6 10/30/2004 06:50:00 7.2 0.8 9.5 5.3 7.3 0.9 9.5 5.3 0.4 0 0.4 0.4 12 6 5 305 0 0 0 0 -5.6 0 -4.9 -5.8 10/30/2004 07:00:00 7.1 0.7 8.8 4.9 7.2 0.7 9.1 5.3 0.4 0 0.4 0.4 18 8 18 305 0 0 0 0 -5.5 0 -5.1 -5.8 10/30/2004 07:10:00 6.7 0.8 8.4 4.6 6.7 0.8 8.4 4.6 0.4 0 0.4 0.4 21 6 26 305 0 0 0 0 -5.5 0 -5.1 -5.6 10/30/2004 07:20:00 5.6 0.6 7.2 3.8 5.7 0.6 7.6 4.2 0.4 0 0.4 0.4 18 10 24 305 0 0 0 0 -5.5 0 -5.1 -5.6 10/30/2004 07:30:00 5 0.7 6.8 3.4 5.1 0.7 6.8 3.4 0.4 0 0.4 0.4 12 7 8 305 0 0 0 0 -5.5 0 -5.1 -5.6 10/30/2004 07:40:00 4.5 0.8 6.1 2.6 4.7 0.8 6.5 3 0.4 0 0.4 0.4 5 8 18 305 0 0 0 0 -5.4 0.1 -4.9 -5.6 10/30/2004 07:50:00 4.4 0.6 5.7 2.6 4.6 0.7 6.1 2.6 0.4 0 0.4 0.4 358 10 354 305 0 0 0 0 -5.3 0 -4.9 -5.6 10/30/2004 08:00:00 4.2 0.8 6.5 2.3 4.5 0.8 6.1 2.6 0.4 0 0.4 0.4 359 10 1 305 0 0 0 0 -5.3 0 -5.1 -5.6 10/30/2004 08:10:00 3.9 0.7 5.7 1.9 4.2 0.7 5.7 2.3 0.4 0 0.4 0.4 1 9 6 305 0 0 0 0 -5.3 0 -5.1 -5.6 10/30/2004 08:20:00 3.7 0.7 5.7 2.3 3.9 0.7 6.1 2.3 0.4 0 0.4 0.4 359 8 357 305 0 0 0 0 -5.3 0 -5.1 -5.6 10/30/2004 08:30:00 3.1 0.6 4.9 1.5 3.3 0.7 5.3 1.9 0.4 0 0.4 0.4 355 13 359 305 0 0 0 0 -5.3 0 -5.1 -5.6 10/30/2004 08:40:00 2.7 1.1 6.5 0.7 2.8 1 6.5 1.1 0.4 0 0.4 0.4 331 17 299 305 0 0 0 0 -5.4 0 -5.3 -5.6 10/30/2004 08:50:00 5.4 0.7 7.2 3.8 5.1 0.6 6.5 3.8 0.4 0 0.4 0.4 296 8 286 305 0 0 0 0 -5.8 0.2 -5.3 -6.2 10/30/2004 09:00:00 3.6 0.6 5.3 2.3 3.5 0.5 5.3 2.3 0.4 0 0.4 0.4 307 18 300 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 09:10:00 3.4 0.4 4.6 2.3 3.6 0.5 4.6 2.6 0.4 0 0.4 0.4 343 13 338 305 0 0 0 0 -6.2 0 -6 -6.4 10/30/2004 09:20:00 3.1 0.4 4.2 2.3 3.3 0.4 4.2 2.3 0.4 0 0.4 0.4 327 12 311 305 0 0 0 0 -6.3 0 -6.2 -6.4 10/30/2004 09:30:00 2.7 0.5 3.8 1.5 2.8 0.5 3.8 1.9 0.4 0 0.4 0.4 330 14 334 305 0 0 0 0 -6.2 0 -6.2 -6.4 10/30/2004 09:40:00 3.3 0.6 4.6 1.5 3.5 0.6 4.9 1.9 0.4 0 0.4 0.4 342 11 351 305 0 0 0 0 -6.1 0 -6 -6.4 10/30/2004 09:50:00 2.8 0.4 4.2 2.3 3 0.4 4.2 2.3 0.4 0 0.4 0.4 6 7 355 305 0 0 0 0 -6.2 0 -6 -6.4 10/30/2004 10:00:00 3 0.5 4.6 1.9 3.2 0.5 4.6 2.3 0.4 0 0.4 0.4 7 7 3 305 0 0 0 0 -6.2 0 -6.2 -6.4 10/30/2004 10:10:00 3.3 0.8 5.3 1.9 3.4 0.8 5.7 1.9 0.4 0 0.4 0.4 18 10 19 305 0 0 0 0 -6.1 0 -5.8 -6.2 10/30/2004 10:20:00 4.1 0.4 4.9 3 4.2 0.4 5.3 3 0.4 0 0.4 0.4 30 7 17 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 10:30:00 4.5 0.4 5.7 3.8 4.7 0.4 6.1 3.4 0.4 0 0.4 0.4 14 12 25 305 0 0 0 0 -6 0 -5.8 -6.2 10/30/2004 10:40:00 5.5 0.9 7.2 3.4 5.6 0.9 7.6 3.4 0.4 0 0.4 0.4 11 6 11 305 0 0 0 0 -5.9 0 -5.8 -6 10/30/2004 10:50:00 6.5 0.6 8.4 4.9 6.5 0.6 8 4.9 0.4 0 0.4 0.4 13 6 12 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 11:00:00 6.5 0.6 8 4.9 6.7 0.6 8 5.3 0.4 0 0.4 0.4 10 5 18 305 0 0 0 0 -6.3 0 -6 -6.4 10/30/2004 11:10:00 6.5 0.5 8 5.3 6.6 0.5 8 5.3 0.4 0 0.4 0.4 11 5 8 305 0 0 0 0 -6.4 0 -6 -6.4 10/30/2004 11:20:00 6.6 0.6 8 4.9 6.8 0.5 8.4 5.3 0.4 0 0.4 0.4 6 6 2 305 0 0 0 0 -6.3 0.1 -6 -6.7 10/30/2004 11:30:00 6.8 0.6 8.4 5.3 6.9 0.6 8.8 5.3 0.4 0 0.4 0.4 7 6 9 305 0 0 0 0 -6.5 0 -6 -6.7 10/30/2004 11:40:00 7 0.6 9.5 5.7 7.2 0.7 9.5 5.7 0.4 0 0.4 0.4 7 7 4 305 0 0 0 0 -6.5 0 -6 -6.7 10/30/2004 11:50:00 7.8 0.5 9.1 6.5 8 0.6 9.5 6.8 0.4 0 0.4 0.4 6 5 4 305 0 0 0 0 -6.7 0 -6.2 -6.9 10/30/2004 12:00:00 7 0.6 8.4 5.3 7.1 0.7 8.8 5.7 0.4 0 0.4 0.4 2 6 4 305 0 0 0 0 -6.7 0 -6.7 -6.9 10/30/2004 12:10:00 6.9 0.8 8.8 5.3 7.1 0.8 8.8 4.9 0.4 0 0.4 0.4 4 6 359 305 0 0 0 0 -6.6 0 -6.2 -6.9 10/30/2004 12:20:00 6.4 0.6 7.6 4.9 6.6 0.6 8 4.9 0.4 0 0.4 0.4 354 11 339 305 0 0 0 0 -6.6 0 -6.4 -6.9 10/30/2004 12:30:00 6.2 0.6 7.6 4.6 6.4 0.6 7.6 4.9 0.4 0 0.4 0.4 349 8 341 305 0 0 0 0 -6.5 0 -6 -6.9 10/30/2004 12:40:00 6.2 0.7 8 4.6 6.5 0.7 8 4.6 0.4 0 0.4 0.4 352 7 357 305 0 0 0 0 -6.6 0 -6.2 -6.9 10/30/2004 12:50:00 6.3 0.8 8.4 4.6 6.5 0.8 8 4.2 0.4 0 0.4 0.4 353 8 353 305 0 0 0 0 -6.5 0.1 -6 -6.7 10/30/2004 13:00:00 6 1.1 9.1 3.8 6.2 1.1 9.1 3.4 0.4 0 0.4 0.4 334 7 350 305 0 0 0 0 -6.4 0.1 -6 -6.7 10/30/2004 13:10:00 5.6 0.8 7.6 4.2 5.8 0.8 8 4.2 0.4 0 0.4 0.4 336 12 344 305 0 0 0 0 -6.6 0 -6.2 -6.9 10/30/2004 13:20:00 6.2 1 8 4.2 6.3 1 8.8 4.2 0.4 0 0.4 0.4 325 11 325 305 0 0 0 0 -6.9 0.1 -6.4 -7.1 10/30/2004 13:30:00 6.3 1 9.1 4.2 6.5 1 9.1 4.2 0.4 0 0.4 0.4 337 9 336 305 0 0 0 0 -6.8 0 -6.7 -6.9 10/30/2004 13:40:00 5.6 1 8 3.4 5.7 1.1 8 3 0.4 0 0.4 0.4 337 10 332 305 0 0 0 0 -6.5 0.1 -6.2 -6.9 10/30/2004 13:50:00 5.8 0.7 7.6 4.2 6 0.7 8 3.8 0.4 0 0.4 0.4 344 9 329 305 0 0 0 0 -6.1 0 -5.8 -6.2 10/30/2004 14:00:00 4.4 1 6.8 2.3 4.5 1 6.8 2.3 0.4 0 0.4 0.4 343 14 318 305 0 0 0 0 -5.9 0 -5.8 -6 10/30/2004 14:10:00 4.2 1.2 6.8 1.9 4.3 1.2 7.2 2.3 0.4 0 0.4 0.4 345 11 345 305 0 0 0 0 -5.8 0 -5.6 -6 10/30/2004 14:20:00 4.6 0.8 6.5 2.3 4.8 0.8 6.5 3 0.4 0 0.4 0.4 351 11 328 305 0 0 0 0 -5.8 0 -5.6 -5.8 10/30/2004 14:30:00 3.9 0.7 5.7 2.6 4.1 0.7 5.7 2.6 0.4 0 0.4 0.4 359 17 359 305 0 0 0 0 -5.9 0.1 -5.6 -6.2 10/30/2004 14:40:00 3.2 0.6 4.6 1.9 3.3 0.5 4.6 2.3 0.4 0 0.4 0.4 334 20 330 305 0 0 0 0 -6 0 -5.8 -6.2 10/30/2004 14:50:00 3.4 0.8 5.3 1.9 3.6 0.8 5.3 1.9 0.4 0 0.4 0.4 351 16 351 305 0 0 0 0 -6.1 0 -6 -6.4 10/30/2004 15:00:00 3.4 0.7 6.1 1.9 3.5 0.7 6.8 1.9 0.4 0 0.4 0.4 355 15 14 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 15:10:00 3.3 0.7 5.3 1.5 3.4 0.7 5.3 1.9 0.4 0 0.4 0.4 359 13 343 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 15:20:00 3.2 1 5.7 1.5 3.4 1 6.1 1.5 0.4 0 0.4 0.4 0 12 13 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 15:30:00 1.9 0.6 3.4 0.4 2.1 0.5 3.4 1.1 0.4 0 0.4 0.4 343 18 346 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 15:40:00 3.1 0.7 4.9 1.1 3.2 0.7 4.9 1.5 0.4 0 0.4 0.4 337 15 335 305 0 0 0 0 -6.1 0 -5.8 -6.2 10/30/2004 15:50:00 3.7 0.7 5.3 1.9 3.9 0.8 5.7 2.3 0.4 0 0.4 0.4 339 15 339 305 0 0 0 0 -6 0 -5.6 -6.2 10/30/2004 16:00:00 3.2 0.6 5.3 1.9 3.2 0.6 5.3 1.9 0.4 0 0.4 0.4 316 15 344 305 0 0 0 0 -6.1 0 -5.6 -6.2 10/30/2004 16:10:00 1 0.8 3 0.4 1.2 0.8 3.4 0.4 0.4 0 0.4 0.4 289 17 300 305 0 0 0 0 -6 0 -5.8 -6.2 10/30/2004 16:20:00 2.9 0.5 4.2 1.9 3.1 0.5 4.6 2.3 0.4 0 0.4 0.4 315 13 315 305 0 0 0 0 -6.1 0 -5.6 -6.2 10/30/2004 16:30:00 2.6 1 4.6 0.4 2.6 0.9 4.6 0.7 0.4 0 0.4 0.4 303 18 291 305 0 0 0 0 -6.1 0 -5.6 -6.2 10/30/2004 16:40:00 1.9 0.6 3.4 0.4 2.2 0.6 3.4 1.1 0.4 0 0.4 0.4 312 8 313 305 0 0 0 0 -6.1 0 -5.6 -6.2 10/30/2004 16:50:00 1.8 0.6 3 0.4 2 0.5 3 1.1 0.4 0 0.4 0.4 309 12 314 305 0 0 0 0 -6.1 0 -5.6 -6.2 10/30/2004 17:00:00 1.6 0.6 3 0.4 1.8 0.6 3 0.4 0.4 0 0.4 0.4 301 20 294 305 0 0 0 0 -6.1 0 -5.8 -6.2 10/30/2004 17:10:00 1.5 0.6 2.6 0.4 1.4 0.5 2.6 0.4 0.4 0 0.4 0.4 270 15 275 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 17:20:00 3.1 1 5.3 1.5 3 1.1 5.3 0.7 0.4 0 0.4 0.4 300 16 310 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 17:30:00 2.7 0.6 4.2 1.5 2.9 0.6 4.6 1.9 0.4 0 0.4 0.4 326 12 323 305 0 0 0 0 -6 0 -5.8 -6.2 10/30/2004 17:40:00 2.7 0.7 4.6 0.7 2.9 0.7 4.6 0.7 0.4 0 0.4 0.4 323 15 344 305 0 0 0 0 -6 0 -5.8 -6 10/30/2004 17:50:00 1.9 1.2 4.2 0.4 2 1.1 4.2 0.4 0.4 0 0.4 0.4 315 8 312 305 0 0 0 0 -6 0 -5.8 -6 10/30/2004 18:00:00 0.9 0.6 2.3 0.4 1.1 0.6 2.6 0.4 0.4 0 0.4 0.4 297 13 306 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 18:10:00 2.4 0.7 4.2 0.7 2.3 0.6 3.8 0.7 0.4 0 0.4 0.4 302 10 305 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 18:20:00 2.3 0.9 4.2 0.4 2.4 1 4.6 0.4 0.4 0 0.4 0.4 297 15 300 305 0 0 0 0 -6.1 0 -5.8 -6.2 10/30/2004 18:30:00 3 0.8 4.6 0.4 3.2 0.7 4.6 1.1 0.4 0 0.4 0.4 330 7 337 305 0 0 0 0 -5.9 0 -5.8 -6 10/30/2004 18:40:00 3 1.5 5.3 0.4 3.1 1.3 4.9 0.4 0.4 0 0.4 0.4 308 15 305 305 0 0 0 0 -5.8 0 -5.6 -6 10/30/2004 18:50:00 3.1 1 4.9 0.7 3.2 0.9 5.3 1.1 0.4 0 0.4 0.4 319 10 312 305 0 0 0 0 -5.9 0 -5.8 -6 10/30/2004 19:00:00 2.9 0.7 4.2 0.7 3.1 0.6 4.6 1.5 0.4 0 0.4 0.4 352 10 354 305 0 0 0 0 -5.8 0 -5.6 -5.8 10/30/2004 19:10:00 3.5 0.9 5.3 1.5 3.6 1 5.7 1.1 0.4 0 0.4 0.4 331 10 335 305 0 0 0 0 -5.7 0 -5.6 -5.8 10/30/2004 19:20:00 2.6 1 4.9 0.4 2.8 1 5.7 1.1 0.4 0 0.4 0.4 354 20 346 305 0 0 0 0 -5.7 0 -5.6 -5.8 10/30/2004 19:30:00 3.9 0.6 5.3 2.3 4 0.6 5.7 1.5 0.4 0 0.4 0.4 17 10 8 305 0 0 0 0 -5.8 0.1 -5.6 -6 10/30/2004 19:40:00 3.6 0.6 4.9 1.9 3.7 0.5 4.9 2.3 0.4 0 0.4 0.4 17 12 2 305 0 0 0 0 -6 0 -5.8 -6.2 10/30/2004 19:50:00 2.5 0.6 4.2 1.5 2.7 0.5 4.6 1.5 0.4 0 0.4 0.4 33 15 2 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 20:00:00 2.9 1 4.6 0.4 3 1 4.6 0.4 0.4 0 0.4 0.4 359 12 358 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 20:10:00 2.4 0.6 3.8 0.4 2.6 0.6 4.2 1.1 0.4 0 0.4 0.4 3 10 8 305 0 0 0 0 -6.2 0 -6 -6.2 10/30/2004 20:20:00 2.8 0.8 4.9 1.1 2.9 0.8 4.9 1.5 0.4 0 0.4 0.4 13 11 8 305 0 0 0 0 -6.1 0 -6 -6.2 10/30/2004 20:30:00 2.9 0.6 4.2 1.1 3.1 0.6 4.6 1.5 0.4 0 0.4 0.4 11 14 26 305 0 0 0 0 -6.2 0 -6 -6.2 10/30/2004 20:40:00 2.7 0.5 3.8 1.5 2.9 0.6 4.2 1.5 0.4 0 0.4 0.4 8 8 21 305 0 0 0 0 -6.2 0 -6 -6.2 10/30/2004 20:50:00 2.6 0.5 3.8 1.5 2.8 0.5 3.8 1.5 0.4 0 0.4 0.4 10 11 15 305 0 0 0 0 -6.2 0 -6.2 -6.2 10/30/2004 21:00:00 3.5 0.8 4.9 1.5 3.7 0.8 5.7 1.9 0.4 0 0.4 0.4 354 10 359 305 0 0 0 0 -6.1 0 -5.6 -6.2 10/30/2004 21:10:00 4.8 0.7 6.5 3 5.1 0.7 6.5 3.4 0.4 0 0.4 0.4 349 9 3 305 0 0 0 0 -6.1 0 -5.6 -6.2 10/30/2004 21:20:00 3.9 0.8 5.7 2.3 4.1 0.7 5.7 2.6 0.4 0 0.4 0.4 354 10 347 305 0 0 0 0 -6.2 0 -5.6 -6.2 10/30/2004 21:30:00 4.6 1 6.5 1.9 4.8 1 6.8 1.9 0.4 0 0.4 0.4 357 13 355 305 0 0 0 0 -6.2 0 -5.6 -6.4 10/30/2004 21:40:00 4.5 0.8 6.1 1.9 4.7 0.7 6.5 2.6 0.4 0 0.4 0.4 357 9 351 305 0 0 0 0 -6.3 0 -5.8 -6.7 10/30/2004 21:50:00 3.8 0.6 5.3 2.6 4.1 0.7 5.7 3 0.4 0 0.4 0.4 354 9 346 305 0 0 0 0 -6.5 0 -6 -6.7 10/30/2004 22:00:00 2.6 0.6 3.8 0.4 2.8 0.6 4.2 1.1 0.4 0 0.4 0.4 346 32 22 305 0 0 0 0 -6.5 0 -6.2 -6.7 10/30/2004 22:10:00 3.8 0.8 7.6 2.6 3.7 0.8 7.6 2.3 0.4 0 0.4 0.4 302 10 337 305 0 0 0 0 -6.5 0 -6.2 -6.7 10/30/2004 22:20:00 5.2 0.6 7.2 3.8 5.5 0.7 7.6 3.8 0.4 0 0.4 0.4 336 7 347 305 0 0 0 0 -6.3 0 -5.8 -6.4 10/30/2004 22:30:00 4.9 1 6.8 3 4.9 1 7.2 2.6 0.4 0 0.4 0.4 319 17 309 305 0 0 0 0 -6.3 0 -5.8 -6.7 10/30/2004 22:40:00 6.4 1.3 9.9 3.4 6.1 1.3 9.9 3.8 0.4 0 0.4 0.4 297 8 305 305 0 0 0 0 -6.5 0 -6.2 -6.9 10/30/2004 22:50:00 6.1 1.2 9.5 3.8 5.8 1.2 9.9 3.4 0.4 0 0.4 0.4 294 12 303 305 0 0 0 0 -6.6 0 -6.4 -6.7 10/30/2004 23:00:00 7.1 0.7 9.1 5.7 6.8 0.7 9.1 4.9 0.4 0 0.4 0.4 302 14 305 305 0 0 0 0 -6.7 0 -6.7 -6.9 10/30/2004 23:10:00 8.1 0.9 10.7 6.5 7.8 1 10.3 6.1 0.4 0 0.4 0.4 300 10 310 305 0 0 0 0 -6.8 0 -6.7 -6.9 10/30/2004 23:20:00 8.1 0.9 9.9 4.9 7.8 0.9 9.9 4.6 0.4 0 0.4 0.4 297 7 292 305 0 0 0 0 -6.9 0 -6.9 -7.1 10/30/2004 23:30:00 7.9 0.8 9.5 6.1 7.6 0.9 9.5 5.3 0.4 0 0.4 0.4 300 10 303 305 0 0 0 0 -7.1 0 -6.9 -7.1 10/30/2004 23:40:00 6.4 1.1 8.8 4.2 6.2 1 8.4 4.2 0.4 0 0.4 0.4 298 8 302 305 0 0 0 0 -7.1 0 -7.1 -7.3 10/30/2004 23:50:00 6.9 0.8 8.8 4.9 6.4 0.8 8.4 4.2 0.4 0 0.4 0.4 290 13 285 305 0 0 0 0 -7.1 0 -7.1 -7.3 10/31/2004 00:00:00 6.9 1 9.1 4.6 6.6 1 8.8 4.6 0.4 0 0.4 0.4 296 9 302 305 0 0 0 0 -7.4 0.1 -7.1 -7.7 10/31/2004 00:10:00 6.7 1 9.5 4.6 6.2 1 9.1 3.8 0.4 0 0.4 0.4 292 13 291 305 0 0 0 0 -7.4 0 -7.3 -7.5 10/31/2004 00:20:00 8 1.1 10.3 5.7 7.6 1 9.9 5.3 0.4 0 0.4 0.4 295 7 302 305 0 0 0 0 -7.4 0 -7.3 -7.5 10/31/2004 00:30:00 6.2 1.2 9.9 3.8 6 1.2 9.1 3.8 0.4 0 0.4 0.4 306 15 298 305 0 0 0 0 -7.4 0 -7.3 -7.5 10/31/2004 00:40:00 7 1.2 9.5 4.2 6.8 1.1 9.5 4.2 0.4 0 0.4 0.4 301 6 294 305 0 0 0 0 -7.5 0.1 -7.3 -7.7 10/31/2004 00:50:00 6.4 1 9.9 3.8 6 0.8 9.5 4.2 0.4 0 0.4 0.4 297 8 299 305 0 0 0 0 -7.5 0 -7.3 -7.7 10/31/2004 01:00:00 6.4 0.9 8.4 4.6 6.3 1 8.4 4.2 0.4 0 0.4 0.4 306 9 296 305 0 0 0 0 -7.2 0 -6.9 -7.3 10/31/2004 01:10:00 5.8 1.1 8.4 3.8 5.7 1 8 3.8 0.4 0 0.4 0.4 302 11 290 305 0 0 0 0 -7.2 0 -6.9 -7.3 10/31/2004 01:20:00 6.9 1 10.7 4.2 6.7 0.9 9.1 4.2 0.4 0 0.4 0.4 299 8 302 305 0 0 0 0 -7.1 0 -7.1 -7.3 10/31/2004 01:30:00 6.2 1 9.1 4.2 5.6 1 8 3.8 0.4 0 0.4 0.4 288 10 296 305 0 0 0 0 -7.2 0 -6.7 -7.3 10/31/2004 01:40:00 6.6 0.9 9.5 4.6 5.8 1 7.6 3.4 0.4 0 0.4 0.4 282 9 285 305 0 0 0 0 -7.1 0 -6.7 -7.3 10/31/2004 01:50:00 6 1.2 10.3 3.8 5.2 1.2 8.8 2.6 0.4 0 0.4 0.4 283 8 280 305 0 0 0 0 -7.1 0 -6.7 -7.1 10/31/2004 02:00:00 6.3 1.1 9.1 3 5.9 1.2 8.8 2.6 0.4 0 0.4 0.4 293 9 302 305 0 0 0 0 -7.1 0 -6.7 -7.3 10/31/2004 02:10:00 5.9 0.9 8.4 4.2 5.6 1 8.4 3.4 0.4 0 0.4 0.4 296 12 294 305 0 0 0 0 -7.2 0 -6.9 -7.3 10/31/2004 02:20:00 5.9 1 8.4 4.2 5.7 1 8.4 3.8 0.4 0 0.4 0.4 303 6 292 305 0 0 0 0 -7.2 0 -6.7 -7.3 10/31/2004 02:30:00 6.3 0.7 7.6 4.6 5.7 0.8 7.6 3.4 0.4 0 0.4 0.4 291 9 300 305 0 0 0 0 -7.3 0 -6.9 -7.5 10/31/2004 02:40:00 5.4 1.1 8 3 5 1 7.6 2.3 0.4 0 0.4 0.4 297 13 301 305 0 0 0 0 -7.4 0 -6.9 -7.5 10/31/2004 02:50:00 5 0.7 7.2 3.4 4.9 0.8 6.8 3 0.4 0 0.4 0.4 306 12 297 305 0 0 0 0 -7.2 0 -7.1 -7.5 10/31/2004 03:00:00 5.1 0.7 7.2 3.4 4.9 0.7 7.2 3 0.4 0 0.4 0.4 297 12 305 305 0 0 0 0 -7.6 0.1 -7.3 -7.9 10/31/2004 03:10:00 4.9 1.2 8.4 1.9 4.8 1.1 7.2 2.3 0.4 0 0.4 0.4 314 13 314 305 0 0 0 0 -7.5 0.1 -7.1 -7.7 10/31/2004 03:20:00 4.9 0.7 6.5 3.4 4.9 0.7 6.5 3.4 0.4 0 0.4 0.4 311 7 307 305 0 0 0 0 -7.4 0 -6.9 -7.5 10/31/2004 03:30:00 4.4 1.1 7.2 2.3 4.4 1 7.2 2.3 0.4 0 0.4 0.4 311 15 298 305 0 0 0 0 -7.1 0 -6.7 -7.3 10/31/2004 03:40:00 4.7 0.9 7.2 3 4.6 1 7.2 3 0.4 0 0.4 0.4 331 29 12 305 0 0 0 0 -7 0.1 -6.2 -7.3 10/31/2004 03:50:00 3.6 1.3 6.5 0.4 3.9 1.2 6.8 0.7 0.4 0 0.4 0.4 350 16 340 305 0 0 0 0 -6.9 0.1 -6.4 -7.1 10/31/2004 04:00:00 2.6 1.1 4.6 0.4 2.7 1.1 4.9 0.4 0.4 0 0.4 0.4 316 20 317 305 0 0 0 0 -7 0 -6.9 -7.1 10/31/2004 04:10:00 3.7 1.2 6.8 0.4 3.6 1.1 6.5 0.4 0.4 0 0.4 0.4 324 17 305 305 0 0 0 0 -7 0.1 -6.9 -7.1 10/31/2004 04:20:00 5.2 0.9 7.2 3.4 5 0.9 7.2 3 0.4 0 0.4 0.4 293 9 300 305 0 0 0 0 -7.3 0.1 -6.9 -7.7 10/31/2004 04:30:00 4.6 0.8 6.5 3 4.5 0.7 6.1 2.6 0.4 0 0.4 0.4 297 8 305 305 0 0 0 0 -7.5 0 -7.3 -7.7 10/31/2004 04:40:00 5.2 1 7.6 3 5 0.9 7.6 3 0.4 0 0.4 0.4 307 8 305 305 0 0 0 0 -7.6 0 -7.3 -7.7 10/31/2004 04:50:00 5.2 1 7.2 3 5.1 0.9 6.8 3 0.4 0 0.4 0.4 300 15 293 305 0 0 0 0 -7.3 0 -7.3 -7.5 10/31/2004 05:00:00 5.5 1.1 7.6 3.8 5.4 1.1 7.2 3.4 0.4 0 0.4 0.4 304 9 303 305 0 0 0 0 -7.5 0 -6.9 -7.7 10/31/2004 05:10:00 5.9 0.7 7.6 4.6 5.6 0.8 7.6 4.2 0.4 0 0.4 0.4 298 11 286 305 0 0 0 0 -7.6 0.1 -7.1 -7.7 10/31/2004 05:20:00 5.8 0.7 8 4.2 5.6 0.7 7.2 3.8 0.4 0 0.4 0.4 301 7 302 305 0 0 0 0 -7.6 0 -7.1 -7.7 10/31/2004 05:30:00 4.9 0.6 6.1 3.8 4.8 0.6 6.5 3.4 0.4 0 0.4 0.4 304 6 310 305 0 0 0 0 -7.4 0 -7.1 -7.7 10/31/2004 05:40:00 5.2 0.6 6.8 3.8 5 0.5 6.5 3.8 0.4 0 0.4 0.4 302 8 302 305 0 0 0 0 -7.1 0 -7.1 -7.3 10/31/2004 05:50:00 5.2 0.7 6.8 3.4 5.2 0.7 6.8 3.4 0.4 0 0.4 0.4 310 15 303 305 0 0 0 0 -7.1 0 -6.9 -7.1 10/31/2004 06:00:00 5.5 1 8 3 5.4 1 7.6 3 0.4 0 0.4 0.4 300 14 300 305 0 0 0 0 -7.1 0 -6.9 -7.1 10/31/2004 06:10:00 5.3 0.8 6.8 2.6 4.9 0.9 6.8 1.9 0.4 0 0.4 0.4 291 11 288 305 0 0 0 0 -7.2 0 -6.9 -7.3 10/31/2004 06:20:00 4.8 0.7 7.6 3.4 4.1 0.9 7.6 1.9 0.4 0 0.4 0.4 283 17 304 305 0 0 0 0 -7.1 0 -7.1 -7.3 10/31/2004 06:30:00 5.1 0.7 7.2 3.4 4.5 0.8 6.8 2.6 0.4 0 0.4 0.4 286 9 295 305 0 0 0 0 -7.1 0 -6.9 -7.3 10/31/2004 06:40:00 5 0.6 6.8 3.4 4.5 0.6 6.5 3 0.4 0 0.4 0.4 286 8 288 305 0 0 0 0 -7.1 0 -7.1 -7.3 10/31/2004 06:50:00 4.9 0.7 6.8 2.6 4.3 0.7 6.5 2.3 0.4 0 0.4 0.4 284 8 275 305 0 0 0 0 -7.2 0 -7.1 -7.3 10/31/2004 07:00:00 4.6 1 7.2 2.3 3.7 1 6.8 1.5 0.4 0 0.4 0.4 275 10 291 305 0 0 0 0 -7.2 0 -7.1 -7.3 10/31/2004 07:10:00 4.9 0.7 6.8 3 4.5 0.7 6.5 2.6 0.4 0 0.4 0.4 288 12 304 305 0 0 0 0 -7.2 0 -7.1 -7.5 10/31/2004 07:20:00 4.8 1 6.8 2.3 4.1 1 6.5 1.9 0.4 0 0.4 0.4 281 10 282 305 0 0 0 0 -7.1 0 -6.9 -7.3 10/31/2004 07:30:00 4.5 0.8 7.2 2.6 3.6 0.7 5.7 1.9 0.4 0 0.4 0.4 273 11 264 305 0 0 0 0 -7.1 0 -6.9 -7.3 10/31/2004 07:40:00 4.8 1 8 2.6 4 0.7 6.8 2.3 0.4 0 0.4 0.4 280 12 275 305 0 0 0 0 -7.1 0 -6.7 -7.3 10/31/2004 07:50:00 4.7 1.1 7.6 2.3 3.8 1 6.5 1.9 0.4 0 0.4 0.4 278 12 291 305 0 0 0 0 -7.2 0 -6.7 -7.3 10/31/2004 08:00:00 4.9 1.2 7.2 2.3 4 1 6.1 1.9 0.4 0 0.4 0.4 277 8 275 305 0 0 0 0 -7.1 0 -6.9 -7.3 10/31/2004 08:10:00 5.5 0.6 7.2 3.8 4.6 0.7 6.1 3 0.4 0 0.4 0.4 278 8 273 305 0 0 0 0 -7 0.1 -6.9 -7.1 10/31/2004 08:20:00 4.7 0.7 6.5 2.6 4.2 0.8 5.7 1.9 0.4 0 0.4 0.4 283 9 287 305 0 0 0 0 -7.1 0 -6.9 -7.1 10/31/2004 08:30:00 5 0.8 7.2 3 4.6 1 6.8 1.9 0.4 0 0.4 0.4 294 13 292 305 0 0 0 0 -7.3 0 -7.1 -7.5 10/31/2004 08:40:00 5.5 0.8 7.6 3.8 5 0.7 6.5 3.4 0.4 0 0.4 0.4 285 7 282 305 0 0 0 0 -7.2 0 -7.1 -7.5 10/31/2004 08:50:00 5.1 0.7 6.8 2.6 4.8 0.7 6.5 3 0.4 0 0.4 0.4 302 11 296 305 0 0 0 0 -7.2 0 -7.1 -7.3 10/31/2004 09:00:00 4.5 0.6 6.1 3.4 4.3 0.5 5.7 3 0.4 0 0.4 0.4 295 6 306 305 0 0 0 0 -7.2 0 -6.9 -7.3 10/31/2004 09:10:00 4.2 0.5 6.1 3 3.8 0.6 5.7 2.3 0.4 0 0.4 0.4 286 9 296 305 0 0 0 0 -7.1 0 -6.7 -7.3 10/31/2004 09:20:00 4.5 0.5 5.7 3 4.3 0.5 5.7 3.4 0.4 0 0.4 0.4 295 11 300 305 0 0 0 0 -7.1 0 -6.7 -7.3 10/31/2004 09:30:00 4.4 0.7 6.5 2.3 4.3 0.7 6.1 3 0.4 0 0.4 0.4 303 10 302 305 0 0 0 0 -7.4 0 -6.9 -7.7 10/31/2004 09:40:00 3.6 0.7 4.9 1.9 3.6 0.7 4.9 2.3 0.4 0 0.4 0.4 295 6 299 305 0 0 0 0 -7.2 0 -6.9 -7.3 10/31/2004 09:50:00 4 0.8 5.3 2.3 3.9 0.9 5.3 1.9 0.4 0 0.4 0.4 290 10 302 305 0 0 0 0 -7.3 0 -6.9 -7.7 10/31/2004 10:00:00 3.7 0.9 5.3 1.9 3.6 0.8 4.9 1.9 0.4 0 0.4 0.4 290 6 283 305 0 0 0 0 -7.2 0 -6.9 -7.3 10/31/2004 10:10:00 2.4 0.6 3.8 1.5 2.5 0.5 3.8 1.5 0.4 0 0.4 0.4 297 7 303 305 0 0 0 0 -7.4 0.1 -7.1 -7.7 10/31/2004 10:20:00 2.7 0.7 4.2 1.5 2.5 0.6 3.8 1.1 0.4 0 0.4 0.4 290 9 303 305 0 0 0 0 -7.7 0.1 -7.5 -7.9 10/31/2004 10:30:00 2.8 0.8 4.2 1.1 2.4 0.6 3.8 0.7 0.4 0 0.4 0.4 284 14 264 305 0 0 0 0 -7.5 0.1 -7.3 -7.7 10/31/2004 10:40:00 2.2 0.7 4.2 0.7 2.2 0.6 3.8 1.1 0.4 0 0.4 0.4 296 10 285 305 0 0 0 0 -7.4 0 -7.3 -7.7 10/31/2004 10:50:00 2.1 0.9 3.8 0.4 2.1 0.6 3.4 0.7 0.4 0 0.4 0.4 289 6 293 305 0 0 0 0 -7.3 0 -7.1 -7.3 10/31/2004 11:00:00 1.4 1.1 3.8 0.4 1.6 0.8 3.4 0.4 0.4 0 0.4 0.4 299 4 297 305 0 0 0 0 -7.2 0 -7.1 -7.5 10/31/2004 11:10:00 1.8 1 3.4 0.4 1.9 0.8 3.4 0.4 0.4 0 0.4 0.4 302 11 294 305 0 0 0 0 -7.5 0 -7.3 -7.7 10/31/2004 11:20:00 2 0.7 3 0.4 1.8 0.8 3 0.4 0.4 0 0.4 0.4 278 6 279 305 0 0 0 0 -7.3 0.2 -6.9 -7.7 10/31/2004 11:30:00 1.3 0.7 3 0.4 1.4 0.6 2.6 0.4 0.4 0 0.4 0.4 285 10 299 305 0 0 0 0 -7 0 -6.9 -7.1 10/31/2004 11:40:00 2 0.5 3 0.7 1.6 0.4 2.6 0.7 0.4 0 0.4 0.4 274 9 252 305 0 0 0 0 -7.2 0 -7.1 -7.5 10/31/2004 11:50:00 1.5 0.8 3.4 0.4 1.4 0.6 2.6 0.4 0.4 0 0.4 0.4 263 17 257 305 0 0 0 0 -6.6 0.2 -6.2 -7.1 10/31/2004 12:00:00 2.5 0.6 3.8 0.7 1.9 0.6 3.4 0.7 0.4 0 0.4 0.4 270 10 287 305 0 0 0 0 -6.4 0 -6.2 -6.4 10/31/2004 12:10:00 2.5 0.5 3.8 1.1 2 0.5 3 0.7 0.4 0 0.4 0.4 263 7 263 305 0 0 0 0 -6.3 0 -6.2 -6.4 10/31/2004 12:20:00 2.3 0.5 3.4 1.1 1.8 0.4 2.6 0.7 0.4 0 0.4 0.4 272 12 275 305 0 0 0 0 -6.2 0 -5.8 -6.2 10/31/2004 12:30:00 2.2 0.3 3 1.5 1.7 0.3 2.3 0.7 0.4 0 0.4 0.4 270 20 269 305 0 0 0 0 -6.5 0.1 -5.8 -6.9 10/31/2004 12:40:00 1.8 0.7 3.8 0.4 1.6 0.6 3.4 0.7 0.4 0 0.4 0.4 282 16 300 305 0 0 0 0 -6.9 0.1 -6.4 -7.1 10/31/2004 12:50:00 1.4 0.8 3 0.4 1.6 0.7 3 0.4 0.4 0 0.4 0.4 294 13 300 305 0 0 0 0 -6.9 0.2 -6 -7.1 10/31/2004 13:00:00 0.9 0.7 2.6 0.4 1.2 0.6 2.6 0.4 0.4 0 0.4 0.4 302 6 306 305 0 0 0 0 -6.1 0 -5.8 -6.4 10/31/2004 13:10:00 1 0.8 2.6 0.4 1.2 0.6 2.3 0.4 0.4 0 0.4 0.4 290 11 276 305 0 0 0 0 -5.6 0.3 -4.9 -6 10/31/2004 13:20:00 0.7 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0 0.4 0.4 272 9 287 305 0 0 0 0 -4.7 0.3 -3.8 -4.9 10/31/2004 13:30:00 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 265 10 285 305 0 0 0 0 -2.8 0.5 -1.8 -3.8 10/31/2004 13:40:00 1.5 0.8 3 0.4 1.6 0.7 3 0.4 0.4 0 0.4 0.4 297 15 305 305 0 0 0 0 -4.5 0.8 -2.7 -5.6 10/31/2004 13:50:00 0.9 0.8 2.6 0.4 1.2 0.8 3 0.4 0.4 0 0.4 0.4 311 28 305 305 0 0 0 0 -5.5 0 -4.9 -5.6 10/31/2004 14:00:00 1.4 1.2 4.2 0.4 1.7 1.1 4.6 0.4 0.4 0 0.4 0.4 353 38 35 305 0 0 0 0 -5.4 0 -4.9 -5.6 10/31/2004 14:10:00 4.5 2 8.4 0.7 4.5 1.9 8.8 1.1 0.4 0 0.4 0.4 42 22 43 305 0 0 0 0 -5.5 0 -4.9 -5.6 10/31/2004 14:20:00 5.4 0.5 6.8 3.8 5.2 0.6 6.8 3.8 0.4 0 0.4 0.4 59 11 54 305 0 0 0 0 -5.5 0.3 -4.7 -6.2 10/31/2004 14:30:00 6 0.5 7.2 4.6 6.1 0.6 7.6 4.2 0.4 0 0.4 0.4 49 7 50 305 0 0 0 0 -6.4 0.1 -6 -6.7 10/31/2004 14:40:00 5.5 0.5 6.8 4.2 5.5 0.6 7.2 4.2 0.4 0 0.4 0.4 47 8 56 305 0 0 0 0 -6.5 0 -6.4 -6.7 10/31/2004 14:50:00 6.1 0.6 8 4.2 6.1 0.7 7.6 4.6 0.4 0 0.4 0.4 43 8 47 305 0 0 0 0 -6.7 0 -6.4 -6.9 10/31/2004 15:00:00 6.2 0.6 8 4.9 6.2 0.7 8 4.6 0.4 0 0.4 0.4 49 7 53 305 0 0 0 0 -6.7 0 -6.7 -6.9 10/31/2004 15:10:00 6.9 0.7 8.4 5.3 7 0.7 8.4 5.3 0.4 0 0.4 0.4 44 5 42 305 0 0 0 0 -6.7 0 -6.7 -6.9 10/31/2004 15:20:00 6 0.6 7.6 4.2 6 0.6 7.6 4.2 0.4 0 0.4 0.4 45 9 45 305 0 0 0 0 -6.7 0 -6.7 -6.9 10/31/2004 15:30:00 6.2 0.6 7.6 4.6 6.3 0.6 8 4.6 0.4 0 0.4 0.4 42 9 48 305 0 0 0 0 -6.7 0 -6.7 -6.9 10/31/2004 15:40:00 6.2 0.6 7.6 4.6 6.3 0.7 8 4.2 0.4 0 0.4 0.4 45 9 38 305 0 0 0 0 -6.8 0 -6.7 -6.9 10/31/2004 15:50:00 5.7 0.5 6.8 4.2 5.7 0.6 7.2 4.2 0.4 0 0.4 0.4 44 9 37 305 0 0 0 0 -6.9 0 -6.7 -7.1 10/31/2004 16:00:00 6.2 0.8 8 4.2 6.2 0.9 8 3.8 0.4 0 0.4 0.4 40 7 36 305 0 0 0 0 -6.8 0 -6.7 -6.9 10/31/2004 16:10:00 5.6 0.8 8.8 3.8 5.6 0.8 8.8 3.8 0.4 0 0.4 0.4 44 8 53 305 0 0 0 0 -6.8 0 -6.7 -6.9 10/31/2004 16:20:00 5.8 0.7 7.2 4.2 5.9 0.8 7.6 4.2 0.4 0 0.4 0.4 47 8 45 305 0 0 0 0 -6.9 0 -6.7 -6.9 10/31/2004 16:30:00 6 0.9 8 3.8 6 1 8 3.8 0.4 0 0.4 0.4 43 9 40 305 0 0 0 0 -6.9 0 -6.7 -6.9 10/31/2004 16:40:00 5.8 0.7 7.2 3.8 5.8 0.7 7.2 4.2 0.4 0 0.4 0.4 39 8 32 305 0 0 0 0 -6.8 0 -6.7 -6.9 10/31/2004 16:50:00 5.6 0.7 7.2 3.8 5.7 0.7 7.6 3.8 0.4 0 0.4 0.4 43 9 35 305 0 0 0 0 -6.9 0 -6.4 -6.9 10/31/2004 17:00:00 6.2 0.6 8.4 4.6 6.2 0.7 8 4.6 0.4 0 0.4 0.4 47 8 59 305 0 0 0 0 -6.9 0 -6.7 -7.1 10/31/2004 17:10:00 5.8 0.6 7.2 4.6 5.8 0.6 7.6 4.2 0.4 0 0.4 0.4 47 8 47 305 0 0 0 0 -6.9 0 -6.7 -7.1 10/31/2004 17:20:00 5.9 0.5 7.6 4.6 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 35 7 44 305 0 0 0 0 -6.9 0 -6.7 -7.1 10/31/2004 17:30:00 6.9 0.6 8.8 5.3 6.9 0.6 9.1 4.9 0.4 0 0.4 0.4 39 7 38 305 0 0 0 0 -6.9 0 -6.9 -7.1 10/31/2004 17:40:00 6.8 0.7 9.1 5.3 6.8 0.7 9.1 5.3 0.4 0 0.4 0.4 34 8 38 305 0 0 0 0 -7 0 -6.9 -7.1 10/31/2004 17:50:00 6.4 0.7 8.4 4.6 6.5 0.7 8.4 4.6 0.4 0 0.4 0.4 38 6 29 305 0 0 0 0 -7 0 -6.9 -7.1 10/31/2004 18:00:00 6.8 0.6 8.4 4.6 6.9 0.7 8.4 4.6 0.4 0 0.4 0.4 36 7 36 305 0 0 0 0 -7 0.1 -6.4 -7.1 10/31/2004 18:10:00 7.3 0.7 9.1 5.3 7.3 0.8 9.5 5.3 0.4 0 0.4 0.4 33 6 29 305 0 0 0 0 -7.1 0 -6.9 -7.1 10/31/2004 18:20:00 7.7 0.8 9.9 5.7 7.7 0.8 9.5 5.3 0.4 0 0.4 0.4 32 7 27 305 0 0 0 0 -7 0 -6.7 -7.1 10/31/2004 18:30:00 7.8 0.8 9.9 6.1 7.8 0.8 9.9 6.1 0.4 0 0.4 0.4 32 6 32 305 0 0 0 0 -7.1 0 -6.7 -7.3 10/31/2004 18:40:00 7.9 0.6 9.9 6.5 7.9 0.7 9.9 5.7 0.4 0 0.4 0.4 32 7 44 305 0 0 0 0 -7.1 0 -6.4 -7.1 10/31/2004 18:50:00 8.1 0.7 10.3 6.5 8.1 0.8 10.7 5.7 0.4 0 0.4 0.4 32 6 33 305 0 0 0 0 -7.1 0 -6.4 -7.3 10/31/2004 19:00:00 8.1 0.7 9.9 6.5 8.1 0.7 9.9 6.5 0.4 0 0.4 0.4 36 6 27 305 0 0 0 0 -7.1 0 -6.9 -7.3 10/31/2004 19:10:00 8.7 0.6 9.9 7.2 8.9 0.6 10.3 7.2 0.4 0 0.4 0.4 41 4 35 305 0 0 0 0 -7.1 0 -6.9 -7.3 10/31/2004 19:20:00 8.3 0.8 10.7 6.5 8.4 0.9 11.1 6.1 0.4 0 0.4 0.4 33 7 28 305 0 0 0 0 -7.1 0 -7.1 -7.3 10/31/2004 19:30:00 7.8 0.9 10.3 6.1 7.8 0.9 9.9 5.7 0.4 0 0.4 0.4 29 7 47 305 0 0 0 0 -7.2 0 -7.1 -7.3 10/31/2004 19:40:00 8.4 0.6 10.3 6.8 8.4 0.7 10.7 7.2 0.4 0 0.4 0.4 34 7 40 305 0 0 0 0 -7.1 0 -7.1 -7.3 10/31/2004 19:50:00 8.5 0.9 11.1 6.1 8.5 0.8 11.1 6.5 0.4 0 0.4 0.4 32 5 32 305 0 0 0 0 -7.1 0 -6.9 -7.3 10/31/2004 20:00:00 8.7 0.6 10.3 6.8 8.8 0.7 10.3 6.5 0.4 0 0.4 0.4 30 8 37 305 0 0 0 0 -7.2 0 -6.7 -7.3 10/31/2004 20:10:00 9 0.8 11.8 7.2 9.1 0.8 11.8 6.8 0.4 0 0.4 0.4 33 8 27 305 0 0 0 0 -7.2 0 -6.9 -7.3 10/31/2004 20:20:00 8.5 0.8 11.1 6.8 8.6 0.9 11.1 6.5 0.4 0 0.4 0.4 33 8 32 305 0 0 0 0 -7.1 0 -6.7 -7.3 10/31/2004 20:30:00 9.1 0.8 11.1 6.8 9.1 0.8 11.5 6.5 0.4 0 0.4 0.4 26 4 26 305 0 0 0 0 -7.2 0 -6.7 -7.3 10/31/2004 20:40:00 9.6 0.9 11.8 7.6 9.6 0.9 12.2 7.6 0.4 0 0.4 0.4 20 6 19 305 0 0 0 0 -7.1 0 -6.7 -7.3 10/31/2004 20:50:00 9.2 0.9 11.5 7.2 9.2 0.9 11.8 6.8 0.4 0 0.4 0.4 28 6 26 305 0 0 0 0 -7.2 0 -6.9 -7.3 10/31/2004 21:00:00 9.1 0.8 11.5 7.2 9.2 0.8 10.7 7.2 0.4 0 0.4 0.4 27 7 20 305 0 0 0 0 -7.2 0 -7.1 -7.3 10/31/2004 21:10:00 9 0.8 10.7 7.2 9.1 0.8 11.1 6.8 0.4 0 0.4 0.4 25 6 36 305 0 0 0 0 -7.4 0 -7.1 -7.5 10/31/2004 21:20:00 9.4 0.8 11.8 6.8 9.4 0.9 11.5 6.8 0.4 0 0.4 0.4 24 5 23 305 0 0 0 0 -7.2 0 -6.7 -7.3 10/31/2004 21:30:00 9.2 0.8 11.8 6.8 9.3 0.9 12.2 6.5 0.4 0 0.4 0.4 26 7 24 305 0 0 0 0 -7.3 0 -6.9 -7.5 10/31/2004 21:40:00 9.4 0.6 11.8 7.6 9.5 0.7 12.2 8 0.4 0 0.4 0.4 36 7 34 305 0 0 0 0 -7.2 0 -6.7 -7.5 10/31/2004 21:50:00 9.1 0.7 10.7 6.8 9.1 0.8 10.7 6.8 0.4 0 0.4 0.4 27 6 22 305 0 0 0 0 -7.2 0 -6.7 -7.3 10/31/2004 22:00:00 8.7 0.7 10.3 6.8 8.8 0.7 10.7 6.8 0.4 0 0.4 0.4 24 5 28 305 0 0 0 0 -7.1 0 -6.7 -7.3 10/31/2004 22:10:00 9.1 0.7 11.1 7.6 9.2 0.8 11.8 7.2 0.4 0 0.4 0.4 25 7 27 305 0 0 0 0 -6.9 0.1 -6.7 -7.1 10/31/2004 22:20:00 9.1 0.9 11.1 6.5 9.2 1 11.1 6.5 0.4 0 0.4 0.4 27 8 13 305 0 0 0 0 -6.9 0.1 -6.2 -7.1 10/31/2004 22:30:00 9 0.8 10.7 7.2 9 0.9 11.1 6.8 0.4 0 0.4 0.4 31 7 30 305 0 0 0 0 -6.8 0 -6.2 -6.9 10/31/2004 22:40:00 9.1 0.8 11.5 7.2 9.1 0.8 11.1 6.8 0.4 0 0.4 0.4 33 5 33 305 0 0 0 0 -6.8 0 -6.2 -6.9 10/31/2004 22:50:00 9 0.7 11.1 6.8 9 0.7 11.1 6.8 0.4 0 0.4 0.4 31 8 32 305 0 0 0 0 -6.8 0 -6.2 -6.9 10/31/2004 23:00:00 9 0.9 11.8 7.2 9 0.9 11.5 7.2 0.4 0 0.4 0.4 34 6 41 305 0 0 0 0 -6.7 0 -6.4 -6.9 10/31/2004 23:10:00 8.8 0.8 10.7 6.8 8.7 0.9 11.1 6.8 0.4 0 0.4 0.4 29 7 20 305 0 0 0 0 -6.7 0.1 -6.2 -6.9 10/31/2004 23:20:00 8.7 0.7 10.7 6.8 8.8 0.7 11.1 6.8 0.4 0 0.4 0.4 35 7 36 305 0 0 0 0 -6.5 0 -6.2 -6.7 10/31/2004 23:30:00 8.3 0.8 10.3 6.5 8.3 0.9 11.1 6.5 0.4 0 0.4 0.4 34 5 37 305 0 0 0 0 -6.5 0 -6 -6.7 10/31/2004 23:40:00 8.7 0.8 11.5 6.8 8.7 0.9 11.5 6.8 0.4 0 0.4 0.4 40 8 46 305 0 0 0 0 -6.3 0 -6.2 -6.4 10/31/2004 23:50:00 9.1 0.7 10.7 7.2 9.2 0.7 10.7 7.6 0.4 0 0.4 0.4 40 5 42 305 0 0 0 0 -6.2 0 -6 -6.4 11/01/2004 00:00:00 9.5 0.8 11.5 7.2 9.5 0.9 11.5 6.8 0.4 0 0.4 0.4 35 7 36 305 0 0 0 0 -5.9 0 -5.6 -6 11/01/2004 00:10:00 9.2 0.8 11.8 7.2 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 37 6 36 305 0 0 0 0 -5.7 0 -5.6 -6 11/01/2004 00:20:00 10.3 0.8 12.2 7.6 10.2 0.8 12.6 8 0.4 0 0.4 0.4 33 6 36 305 0 0 0 0 -5.5 0 -4.9 -5.8 11/01/2004 00:30:00 10.4 0.8 11.8 8.4 10.5 0.8 12.6 8.8 0.4 0 0.4 0.4 39 7 32 305 0 0 0 0 -5.5 0 -4.9 -5.8 11/01/2004 00:40:00 10.3 1 13.7 8 10.3 1 13.3 8 0.4 0 0.4 0.4 39 7 58 305 0 0 0 0 -5.5 0 -4.9 -5.6 11/01/2004 00:50:00 11 1 13 8.8 10.9 1 13.3 8.4 0.4 0 0.4 0.4 33 8 25 305 0 0 0 0 -5.3 0.1 -4.7 -5.6 11/01/2004 01:00:00 10.6 0.7 13 8.4 10.6 0.8 13 8.8 0.4 0 0.4 0.4 38 7 41 305 0 0 0 0 -5.3 0 -4.9 -5.6 11/01/2004 01:10:00 10.3 0.8 12.6 7.6 10.3 0.9 13 8 0.4 0 0.4 0.4 46 6 54 305 0 0 0 0 -5.4 0 -4.9 -5.6 11/01/2004 01:20:00 9.6 0.9 13 7.6 9.6 0.9 13.3 7.2 0.4 0 0.4 0.4 42 6 39 305 0 0 0 0 -5.3 0 -4.7 -5.6 11/01/2004 01:30:00 9.8 0.8 12.2 7.2 9.8 0.9 12.2 7.6 0.4 0 0.4 0.4 39 7 37 305 0 0 0 0 -5.1 0 -4.5 -5.3 11/01/2004 01:40:00 9.8 0.6 12.2 8.4 9.8 0.6 11.8 8 0.4 0 0.4 0.4 44 6 37 305 0 0 0 0 -5 0 -4.5 -5.1 11/01/2004 01:50:00 10.5 0.8 12.2 8.4 10.4 0.8 12.2 8.4 0.4 0 0.4 0.4 45 4 44 305 0 0 0 0 -5 0 -4.7 -5.1 11/01/2004 02:00:00 10.7 0.8 13.7 9.1 10.7 0.9 14.1 8.8 0.4 0 0.4 0.4 44 9 45 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/01/2004 02:10:00 10.7 0.9 13.7 8.8 10.7 1 14.1 8 0.4 0 0.4 0.4 51 5 52 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/01/2004 02:20:00 10.9 0.9 13 8.4 10.8 0.9 13 8.4 0.4 0 0.4 0.4 49 8 42 305 0 0 0 0 -4.7 0.1 -4.5 -4.9 11/01/2004 02:30:00 10.9 0.7 12.6 8.8 10.9 0.7 13 9.1 0.4 0 0.4 0.4 46 5 44 305 0 0 0 0 -4.7 0 -4.5 -4.9 11/01/2004 02:40:00 10.9 0.8 13.3 9.1 10.8 0.8 13 8.4 0.4 0 0.4 0.4 50 6 57 305 0 0 0 0 -4.5 0 -4.2 -4.7 11/01/2004 02:50:00 10.2 0.9 12.6 8 10.1 1 12.2 7.6 0.4 0 0.4 0.4 50 9 46 305 0 0 0 0 -4.5 0 -4.2 -4.7 11/01/2004 03:00:00 9.9 0.9 12.2 8 9.9 0.9 12.2 7.6 0.4 0 0.4 0.4 50 9 55 305 0 0 0 0 -4.4 0 -3.8 -4.5 11/01/2004 03:10:00 10.3 1 12.6 8 10 1.2 12.6 7.2 0.4 0 0.4 0.4 53 10 44 305 0 0 0 0 -4.3 0 -3.8 -4.5 11/01/2004 03:20:00 11.4 0.9 13.3 8.8 11.3 1 13.3 8 0.4 0 0.4 0.4 64 4 61 305 0 0 0 0 -4.4 0 -4 -4.7 11/01/2004 03:30:00 11.5 0.9 13.3 9.1 11.4 1 13.7 8.4 0.4 0 0.4 0.4 55 8 61 305 0 0 0 0 -4.2 0 -4 -4.5 11/01/2004 03:40:00 11.2 0.9 13.3 8.8 11.1 1 13 8.8 0.4 0 0.4 0.4 58 7 70 305 0 0 0 0 -4.2 0 -4 -4.5 11/01/2004 03:50:00 11.7 0.9 13.7 8.8 11.6 1 13.7 8.8 0.4 0 0.4 0.4 61 7 62 305 0 0 0 0 -4.1 0 -3.6 -4.2 11/01/2004 04:00:00 11.6 0.9 13.7 9.5 11.6 1 14.5 8.8 0.4 0 0.4 0.4 59 5 50 305 0 0 0 0 -4 0 -3.8 -4.2 11/01/2004 04:10:00 11.5 1 13.7 9.1 11.5 1 13.7 8.4 0.4 0 0.4 0.4 55 5 53 305 0 0 0 0 -3.9 0 -3.3 -4 11/01/2004 04:20:00 11.3 0.8 13.7 9.5 11.3 1 13.3 8 0.4 0 0.4 0.4 60 5 64 305 0 0 0 0 -3.9 0 -3.3 -4 11/01/2004 04:30:00 11.3 0.8 13 9.1 11.2 0.9 13.3 8.8 0.4 0 0.4 0.4 51 5 46 305 0 0 0 0 -3.8 0 -3.3 -4 11/01/2004 04:40:00 11.2 0.7 13 9.5 11.1 0.8 13.3 9.5 0.4 0 0.4 0.4 54 7 67 305 0 0 0 0 -3.9 0 -3.3 -3.8 11/01/2004 04:50:00 10.6 0.8 13.7 8.4 10.6 0.8 13.7 8 0.4 0 0.4 0.4 54 10 65 305 0 0 0 0 -3.8 0 -3.3 -3.8 11/01/2004 05:00:00 10.8 1 13.3 8 10.8 1.1 13.3 8 0.4 0 0.4 0.4 53 5 49 305 0 0 0 0 -3.7 0.1 -3.6 -3.8 11/01/2004 05:10:00 11.6 1 13.7 8.8 11.6 1 13.7 8.8 0.4 0 0.4 0.4 54 6 61 305 0 0 0 0 -3.8 0 -3.6 -3.8 11/01/2004 05:20:00 12.4 0.8 14.1 10.3 12.3 0.9 14.1 9.9 0.4 0 0.4 0.4 51 5 47 305 0 0 0 0 -3.8 0 -3.6 -3.8 11/01/2004 05:30:00 12.2 0.9 15.3 10.3 12.1 1 14.9 9.5 0.4 0 0.4 0.4 54 6 60 305 0 0 0 0 -3.8 0 -3.6 -3.8 11/01/2004 05:40:00 12 0.8 13.7 9.5 11.8 1 13.7 9.1 0.4 0 0.4 0.4 56 6 50 305 0 0 0 0 -3.7 0 -3.6 -3.8 11/01/2004 05:50:00 12.1 0.8 13.7 10.3 12 1 14.1 9.1 0.4 0 0.4 0.4 49 6 56 305 0 0 0 0 -3.6 0 -3.3 -3.8 11/01/2004 06:00:00 12.9 0.9 14.9 10.7 12.8 1 15.3 10.3 0.4 0 0.4 0.4 46 5 54 305 0 0 0 0 -3.6 0 -3.3 -3.8 11/01/2004 06:10:00 12.9 0.8 14.9 10.7 12.8 1 14.9 9.9 0.4 0 0.4 0.4 50 5 54 305 0 0 0 0 -3.6 0 -3.3 -3.8 11/01/2004 06:20:00 12.8 1 15.3 10.3 12.7 1.1 15.3 9.5 0.4 0 0.4 0.4 47 6 47 305 0 0 0 0 -3.6 0 -3.3 -3.8 11/01/2004 06:30:00 12.3 0.9 14.5 9.5 12.2 1 14.5 9.1 0.4 0 0.4 0.4 47 6 41 305 0 0 0 0 -3.5 0 -3.1 -3.6 11/01/2004 06:40:00 12.8 1 15.3 9.9 12.7 1 15.6 9.1 0.4 0 0.4 0.4 44 5 43 305 0 0 0 0 -3.4 0 -2.9 -3.6 11/01/2004 06:50:00 12.9 1.7 17.6 10.3 12.8 1.7 17.2 9.9 0.4 0 0.4 0.4 51 7 59 305 0 0 0 0 -3.4 0 -3.1 -3.6 11/01/2004 07:00:00 15.1 1.1 17.6 12.2 15 1.2 17.6 11.8 0.4 0 0.4 0.4 53 5 70 305 0 0 0 0 -3.9 0.2 -3.3 -4.2 11/01/2004 07:10:00 14.6 1.4 17.6 10.7 14.6 1.5 18.3 11.1 0.4 0 0.4 0.4 47 5 55 305 0 0 0 0 -3.9 0 -3.3 -4 11/01/2004 07:20:00 15.1 1.1 17.6 11.5 15 1.2 17.6 11.5 0.4 0 0.4 0.4 43 5 37 305 0 0 0 0 -4 0.1 -3.3 -4.2 11/01/2004 07:30:00 15.2 1 17.2 11.5 15 1 17.2 11.8 0.4 0 0.4 0.4 35 5 33 305 0 0 0 0 -3.9 0 -3.3 -4 11/01/2004 07:40:00 15.4 1 18.3 13 15.4 1 18.7 12.2 0.4 0 0.4 0.4 34 5 24 305 0 0 0 0 -3.9 0 -3.3 -4 11/01/2004 07:50:00 14.8 1.1 17.6 12.2 14.7 1.1 17.2 11.8 0.4 0 0.4 0.4 32 5 29 305 0 0 0 0 -3.9 0 -3.3 -4 11/01/2004 08:00:00 15.1 1.2 17.6 11.5 15 1.2 17.6 11.5 0.4 0 0.4 0.4 34 4 36 305 0 0 0 0 -3.8 0 -3.6 -4 11/01/2004 08:10:00 14.6 0.9 16.8 12.2 14.6 1 17.2 11.5 0.4 0 0.4 0.4 33 5 33 305 0 0 0 0 -3.8 0 -3.6 -3.8 11/01/2004 08:20:00 15.2 1.1 17.6 11.5 15.2 1.2 17.6 11.5 0.4 0 0.4 0.4 33 5 28 305 0 0 0 0 -3.7 0.1 -3.3 -4 11/01/2004 08:30:00 14.8 1.2 18.3 11.8 14.7 1.2 17.9 11.8 0.4 0 0.4 0.4 34 5 35 305 0 0 0 0 -3.9 0 -3.8 -4 11/01/2004 08:40:00 15.6 1 18.7 13 15.4 1.1 19.1 13 0.4 0 0.4 0.4 30 4 29 305 0 0 0 0 -3.8 0 -3.3 -3.8 11/01/2004 08:50:00 15.9 1 18.7 13 15.8 1.1 18.7 12.2 0.4 0 0.4 0.4 36 6 31 305 0 0 0 0 -3.9 0 -3.3 -4 11/01/2004 09:00:00 15.8 1.2 18.7 12.6 15.7 1.2 18.7 12.2 0.4 0 0.4 0.4 35 5 35 305 0 0 0 0 -3.9 0 -3.6 -4 11/01/2004 09:10:00 16 1 17.9 12.6 15.8 1.1 17.9 12.6 0.4 0 0.4 0.4 34 5 35 305 0 0 0 0 -4.1 0 -3.8 -4.2 11/01/2004 09:20:00 15.4 1.1 17.9 11.8 15.3 1.1 17.6 11.8 0.4 0 0.4 0.4 33 5 30 305 0 0 0 0 -4 0.1 -3.6 -4.2 11/01/2004 09:30:00 14.9 1 17.2 11.8 14.8 0.9 17.2 11.5 0.4 0 0.4 0.4 34 6 31 305 0 0 0 0 -3.8 0 -3.6 -3.8 11/01/2004 09:40:00 15.2 1.1 18.3 12.2 15.1 1.2 18.3 12.2 0.4 0 0.4 0.4 33 6 34 305 0 0 0 0 -3.7 0 -3.6 -3.8 11/01/2004 09:50:00 15.3 1.2 17.9 11.8 15.1 1.3 18.3 11.5 0.4 0 0.4 0.4 30 5 30 305 0 0 0 0 -3.7 0 -3.3 -3.8 11/01/2004 10:00:00 15.2 1 17.6 12.2 15.1 1 17.6 12.6 0.4 0 0.4 0.4 27 5 25 305 0 0 0 0 -3.7 0 -3.1 -3.8 11/01/2004 10:10:00 14.9 1.1 17.9 12.2 14.8 1.1 17.9 12.2 0.4 0 0.4 0.4 32 7 17 305 0 0 0 0 -3.6 0 -3.1 -3.8 11/01/2004 10:20:00 15.2 1.1 19.1 12.6 15.2 1.1 18.7 12.2 0.4 0 0.4 0.4 30 6 30 305 0 0 0 0 -3.7 0.1 -3.3 -3.8 11/01/2004 10:30:00 15 1.1 17.9 12.2 14.9 1.1 17.6 12.6 0.4 0 0.4 0.4 31 4 32 305 0 0 0 0 -3.6 0.1 -3.1 -3.8 11/01/2004 10:40:00 15.1 1.1 17.9 12.6 15 1.3 17.9 11.5 0.4 0 0.4 0.4 28 6 27 305 0 0 0 0 -3.6 0 -3.1 -3.8 11/01/2004 10:50:00 14.7 1.3 17.9 11.5 14.5 1.4 17.9 10.7 0.4 0 0.4 0.4 30 6 25 305 0 0 0 0 -3.5 0 -2.9 -3.8 11/01/2004 11:00:00 15.8 1.1 18.7 12.6 15.7 1.2 18.7 11.8 0.4 0 0.4 0.4 33 5 40 305 0 0 0 0 -3.5 0 -3.1 -3.8 11/01/2004 11:10:00 16.1 1 18.7 13 16 1.1 19.1 12.2 0.4 0 0.4 0.4 28 5 30 305 0 0 0 0 -3.6 0 -3.1 -3.8 11/01/2004 11:20:00 15.6 1.2 20.2 13 15.6 1.2 20.6 12.6 0.4 0 0.4 0.4 26 6 25 305 0 0 0 0 -3.6 0 -3.1 -3.8 11/01/2004 11:30:00 15.8 1.2 17.9 13 15.7 1.2 18.7 12.2 0.4 0 0.4 0.4 30 5 26 305 0 0 0 0 -3.6 0 -3.1 -3.8 11/01/2004 11:40:00 16.2 1.3 19.1 12.2 16 1.5 18.7 11.8 0.4 0 0.4 0.4 29 5 29 305 0 0 0 0 -3.6 0 -3.1 -3.8 11/01/2004 11:50:00 16 1.2 18.7 12.6 15.9 1.3 19.1 12.2 0.4 0 0.4 0.4 28 6 31 305 0 0 0 0 -3.7 0.1 -3.1 -3.8 11/01/2004 12:00:00 16 1 17.9 13.3 15.9 1 17.9 13.3 0.4 0 0.4 0.4 25 5 27 305 0 0 0 0 -3.7 0.1 -3.3 -3.8 11/01/2004 12:10:00 16.6 1.2 19.1 13 16.5 1.3 19.5 13 0.4 0 0.4 0.4 22 5 21 305 0 0 0 0 -3.9 0 -3.3 -4 11/01/2004 12:20:00 16.8 1 19.1 14.1 16.7 1.1 19.1 13.3 0.4 0 0.4 0.4 19 4 15 305 0 0 0 0 -3.8 0.1 -3.3 -4 11/01/2004 12:30:00 17.1 1.3 19.5 13 17 1.5 19.5 13.3 0.4 0 0.4 0.4 21 4 24 305 0 0 0 0 -3.8 0 -3.3 -4 11/01/2004 12:40:00 17 1.2 19.9 13.7 17 1.2 19.5 13 0.4 0 0.4 0.4 19 4 18 305 0 0 0 0 -3.8 0 -3.3 -4 11/01/2004 12:50:00 16.7 1.1 19.5 13.7 16.7 1.1 19.1 13.3 0.4 0 0.4 0.4 19 4 16 305 0 0 0 0 -3.8 0.1 -3.3 -4 11/01/2004 13:00:00 15.9 1.2 19.1 13 15.9 1.4 19.5 12.6 0.4 0 0.4 0.4 14 4 14 305 0 0 0 0 -3.7 0.1 -3.1 -4 11/01/2004 13:10:00 15.3 1 18.3 12.6 15.2 1 19.1 12.6 0.4 0 0.4 0.4 29 10 58 305 0 0 0 0 -3.5 0 -2.9 -3.6 11/01/2004 13:20:00 15.6 1.5 19.1 12.2 15.5 1.5 19.5 12.2 0.4 0 0.4 0.4 35 6 45 305 0 0 0 0 -3.1 0.1 -2.7 -3.3 11/01/2004 13:30:00 16 1.2 18.3 12.2 15.9 1.1 18.3 13 0.4 0 0.4 0.4 37 5 33 305 0 0 0 0 -3.2 0 -2.9 -3.3 11/01/2004 13:40:00 15.7 1.1 18.3 13 15.5 1.3 17.9 11.8 0.4 0 0.4 0.4 32 4 38 305 0 0 0 0 -3.1 0.2 -2.7 -3.6 11/01/2004 13:50:00 16.5 1 18.7 13.7 16.3 1.1 19.5 13.3 0.4 0 0.4 0.4 34 5 32 305 0 0 0 0 -3.2 0 -3.1 -3.3 11/01/2004 14:00:00 17 1.2 20.2 13.7 16.7 1.2 19.5 13 0.4 0 0.4 0.4 31 5 33 305 0 0 1 0 -3.1 0 -2.9 -3.3 11/01/2004 14:10:00 15.9 1.4 19.1 11.5 15.7 1.4 19.1 11.5 0.4 0 0.4 0.4 34 6 37 305 0 0 0 0 -2.9 0 -2.7 -3.1 11/01/2004 14:20:00 16.3 1 18.7 13.7 16.1 1.1 18.3 13 0.4 0 0.4 0.4 30 5 35 305 0 0 0 0 -2.9 0 -2.7 -3.1 11/01/2004 14:30:00 16.2 1.4 19.5 12.6 16.1 1.5 20.2 11.8 0.4 0 0.4 0.4 31 6 32 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/01/2004 14:40:00 17 1.4 20.2 13 16.9 1.5 20.2 12.6 0.4 0 0.4 0.4 32 6 38 305 0 0 0 0 -2.8 0 -2.7 -3.1 11/01/2004 14:50:00 17.6 1.2 20.6 14.9 17.5 1.4 20.6 12.6 0.4 0 0.4 0.4 27 6 25 305 0 0 0 0 -2.9 0 -2.7 -3.1 11/01/2004 15:00:00 17.7 1.3 21.4 13.7 17.3 1.5 21.4 13.7 0.4 0 0.4 0.4 28 5 28 305 0 0 0 0 -2.8 0 -2.7 -3.1 11/01/2004 15:10:00 17.4 1.5 20.6 14.1 17 1.6 21 13.3 0.4 0 0.4 0.4 27 5 24 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/01/2004 15:20:00 17.7 1.3 21.4 14.1 17.5 1.3 21.4 13.7 0.4 0 0.4 0.4 30 5 27 305 0 0 0 0 -2.9 0 -2.7 -3.1 11/01/2004 15:30:00 18.3 1.5 22.6 14.9 18 1.5 22.1 14.5 0.4 0 0.4 0.4 32 5 29 305 0 0 0 0 -3 0.1 -2.7 -3.3 11/01/2004 15:40:00 18.7 1.6 21.8 13.7 18.6 1.7 22.1 14.5 0.4 0 0.4 0.4 30 5 27 305 0 0 0 0 -3.3 0.1 -2.7 -3.6 11/01/2004 15:50:00 19.2 1.2 21.8 15.6 18.8 1.3 21.4 14.9 0.4 0 0.4 0.4 33 5 31 305 0 0 0 0 -3.7 0.2 -2.9 -4 11/01/2004 16:00:00 18.7 1.6 21 14.5 18.5 1.7 21.4 13.7 0.4 0 0.4 0.4 31 5 28 305 0 0 0 0 -3.7 0.2 -3.1 -4 11/01/2004 16:10:00 18.8 1.2 21.4 14.5 18.5 1.3 21.4 13.7 0.4 0 0.4 0.4 33 5 33 305 1 0 0 0 -3.6 0 -3.1 -3.8 11/01/2004 16:20:00 19 1.5 22.9 15.3 18.6 1.6 22.6 14.1 0.4 0 0.4 0.4 33 5 33 305 0 0 0 0 -3.5 0 -2.9 -3.8 11/01/2004 16:30:00 18.5 1.3 21 14.1 18.1 1.3 21.4 14.1 0.4 0 0.4 0.4 33 5 35 305 0 0 0 0 -3.4 0 -3.1 -3.6 11/01/2004 16:40:00 18.4 1.3 21 14.9 18.1 1.4 21 14.5 0.4 0 0.4 0.4 33 5 35 305 0 0 0 0 -3.4 0 -3.1 -3.6 11/01/2004 16:50:00 18.4 1.5 21.4 13.7 18.1 1.5 21 13.7 0.4 0 0.4 0.4 34 5 29 305 0 0 0 0 -3.2 0 -2.7 -3.3 11/01/2004 17:00:00 19.2 1.3 22.6 16.1 18.8 1.4 22.9 15.6 0.4 0 0.4 0.4 32 5 37 305 0 0 0 0 -3.3 0 -3.1 -3.6 11/01/2004 17:10:00 18.7 1.5 22.1 14.9 18.3 1.5 22.1 13.7 0.4 0 0.4 0.4 28 5 28 305 0 0 0 0 -3.3 0 -3.1 -3.3 11/01/2004 17:20:00 18.6 1.6 22.1 14.9 18.3 1.6 21.8 14.1 0.4 0 0.4 0.4 32 5 27 305 0 0 0 0 -3.3 0 -3.1 -3.6 11/01/2004 17:30:00 19 1.7 22.1 14.9 18.7 1.7 21.8 14.5 0.4 0 0.4 0.4 32 6 31 305 0 0 0 0 -3.3 0 -3.1 -3.6 11/01/2004 17:40:00 18.9 1.3 21.8 14.5 18.6 1.5 21.8 14.5 0.4 0 0.4 0.4 33 5 35 305 0 0 0 0 -3.3 0 -3.1 -3.6 11/01/2004 17:50:00 18.6 1.5 22.1 14.1 18.2 1.6 21.4 14.1 0.4 0 0.4 0.4 29 5 35 305 0 0 0 0 -3.5 0 -3.1 -3.8 11/01/2004 18:00:00 19.5 1.5 22.9 15.6 19.3 1.5 22.9 15.3 0.4 0 0.4 0.4 30 5 36 305 0 0 0 0 -3.6 0 -3.3 -3.8 11/01/2004 18:10:00 19.3 1.6 23.7 14.9 19 1.7 22.9 14.1 0.4 0 0.4 0.4 30 6 40 305 0 0 0 0 -3.7 0 -3.3 -3.8 11/01/2004 18:20:00 19.3 1.3 22.1 15.6 19.2 1.4 22.9 15.3 0.4 0 0.4 0.4 29 7 35 305 0 0 0 0 -3.6 0.1 -3.3 -3.8 11/01/2004 18:30:00 19.5 1.5 22.6 14.9 19.2 1.7 22.1 14.5 0.4 0 0.4 0.4 30 5 33 305 0 0 0 0 -3.7 0 -3.3 -4 11/01/2004 18:40:00 19.6 1.3 22.6 16.1 19.4 1.3 22.1 15.6 0.4 0 0.4 0.4 27 6 28 305 0 0 0 0 -3.9 0 -3.8 -4 11/01/2004 18:50:00 18.8 1.5 21.8 14.9 18.5 1.5 21.8 14.9 0.4 0 0.4 0.4 27 5 33 305 0 0 0 0 -3.8 0.1 -3.3 -4 11/01/2004 19:00:00 19 1.6 23.3 13.3 18.7 1.7 22.6 13.3 0.4 0 0.4 0.4 26 5 31 305 0 0 0 0 -3.8 0 -3.3 -4 11/01/2004 19:10:00 19.1 1.7 23.3 14.9 18.8 1.8 23.3 14.9 0.4 0 0.4 0.4 25 5 23 305 0 0 0 0 -3.9 0.1 -3.6 -4 11/01/2004 19:20:00 19.2 1.5 22.1 14.5 18.9 1.5 21.8 14.1 0.4 0 0.4 0.4 26 5 24 305 0 0 0 0 -4 0 -3.8 -4 11/01/2004 19:30:00 19.3 1.6 22.6 14.9 19.1 1.7 22.6 14.9 0.4 0 0.4 0.4 26 6 31 305 0 0 0 0 -4 0 -3.8 -4.2 11/01/2004 19:40:00 19 1.6 22.6 13.7 18.8 1.7 22.6 14.1 0.4 0 0.4 0.4 22 6 27 305 0 0 0 0 -4.1 0.1 -3.8 -4.2 11/01/2004 19:50:00 18.5 1.5 21.8 14.5 18.3 1.6 22.1 13.3 0.4 0 0.4 0.4 26 5 22 305 0 0 0 0 -4.2 0.1 -3.8 -4.5 11/01/2004 20:00:00 18.6 1.3 21.8 14.5 18.4 1.5 21.8 14.1 0.4 0 0.4 0.4 29 5 38 305 0 0 0 0 -4.1 0 -3.6 -4.2 11/01/2004 20:10:00 18.2 1.4 21.4 14.1 18 1.5 21.4 14.5 0.4 0 0.4 0.4 26 5 18 305 0 0 0 0 -4.1 0 -3.8 -4.5 11/01/2004 20:20:00 18.6 1.3 22.1 14.1 18.4 1.3 22.6 14.9 0.4 0 0.4 0.4 24 5 23 305 0 0 0 0 -4.1 0 -4 -4.2 11/01/2004 20:30:00 17.9 1.5 21.4 13.3 17.7 1.4 22.1 13.3 0.4 0 0.4 0.4 26 6 31 305 0 0 0 0 -4 0 -3.8 -4.2 11/01/2004 20:40:00 17 1.6 20.6 13 16.8 1.6 21 13.3 0.4 0 0.4 0.4 25 6 28 305 0 0 0 0 -3.9 0 -3.6 -4.2 11/01/2004 20:50:00 18.1 1.4 21.4 13.7 17.8 1.5 21 13.7 0.4 0 0.4 0.4 25 7 30 305 0 0 0 0 -4.2 0 -3.8 -4.5 11/01/2004 21:00:00 17.9 1.4 21.8 14.1 17.8 1.5 21 14.1 0.4 0 0.4 0.4 24 5 17 305 0 0 0 0 -4.1 0 -3.8 -4.2 11/01/2004 21:10:00 18.2 1.6 21.4 13 17.8 1.7 21 12.6 0.4 0 0.4 0.4 24 6 27 305 0 0 0 0 -4 0 -3.3 -4.2 11/01/2004 21:20:00 18.3 1.1 21 14.5 18.3 1.2 21 14.9 0.4 0 0.4 0.4 22 5 18 305 0 0 0 0 -4.1 0 -3.8 -4.5 11/01/2004 21:30:00 17.8 1.5 22.6 13.3 17.7 1.6 22.6 13 0.4 0 0.4 0.4 26 6 26 305 0 0 0 0 -4.1 0 -3.8 -4.2 11/01/2004 21:40:00 18.1 1.2 21.4 14.9 17.9 1.3 21 14.9 0.4 0 0.4 0.4 23 6 23 305 0 0 0 0 -4.2 0.1 -3.8 -4.5 11/01/2004 21:50:00 18.3 1.2 21 14.5 18.1 1.3 20.6 14.1 0.4 0 0.4 0.4 23 5 20 305 0 0 0 0 -4.2 0 -3.8 -4.5 11/01/2004 22:00:00 17.8 1.2 21 13.7 17.6 1.5 21.4 13.7 0.4 0 0.4 0.4 27 6 27 305 0 0 0 0 -4 0 -3.6 -4.5 11/01/2004 22:10:00 17.7 1.3 21 14.1 17.6 1.3 20.6 13.7 0.4 0 0.4 0.4 27 5 26 305 0 0 0 0 -4 0 -3.3 -4.2 11/01/2004 22:20:00 17.5 1.2 21 13.7 17.3 1.3 20.6 13.3 0.4 0 0.4 0.4 28 4 39 305 0 0 0 0 -4 0 -3.6 -4 11/01/2004 22:30:00 17.5 1.3 19.9 13.7 17.3 1.5 21 13 0.4 0 0.4 0.4 22 5 19 305 0 0 0 0 -4 0 -3.8 -4.2 11/01/2004 22:40:00 17.9 1.2 20.2 12.6 17.7 1.3 20.6 13 0.4 0 0.4 0.4 24 5 23 305 0 0 0 0 -4.1 0 -3.8 -4.2 11/01/2004 22:50:00 17.7 1.1 21 14.9 17.7 1.2 21 14.5 0.4 0 0.4 0.4 23 4 27 305 0 0 0 0 -4.1 0 -4 -4.2 11/01/2004 23:00:00 17.7 1.4 21 13.3 17.6 1.4 21.4 13.3 0.4 0 0.4 0.4 27 4 29 305 0 0 0 0 -4 0 -3.8 -4.2 11/01/2004 23:10:00 17.7 1.2 20.2 14.1 17.6 1.2 20.2 13.7 0.4 0 0.4 0.4 23 5 25 305 0 0 0 0 -4 0 -3.8 -4.2 11/01/2004 23:20:00 17.8 1.3 20.6 14.5 17.7 1.3 20.6 14.5 0.4 0 0.4 0.4 24 5 23 305 0 0 0 0 -4 0 -3.8 -4 11/01/2004 23:30:00 17.7 1.3 21 13.7 17.5 1.4 21 13.3 0.4 0 0.4 0.4 23 6 30 305 0 0 0 0 -4 0 -3.8 -4.2 11/01/2004 23:40:00 17.6 1.5 21 13.7 17.4 1.5 21 13.3 0.4 0 0.4 0.4 25 5 25 305 0 0 0 0 -4 0 -3.8 -4.2 11/01/2004 23:50:00 18 1.3 20.6 13.7 17.9 1.3 20.6 14.5 0.4 0 0.4 0.4 24 5 19 305 0 0 0 0 -4.1 0 -3.8 -4.2 11/02/2004 00:00:00 18.2 1.2 21.4 14.5 18.2 1.2 21 14.5 0.4 0 0.4 0.4 22 5 23 305 0 0 0 0 -4.1 0.1 -3.8 -4.5 11/02/2004 00:10:00 18 1.7 21.4 13 17.8 1.8 21.4 12.6 0.4 0 0.4 0.4 24 6 21 305 0 0 0 0 -4.2 0 -3.8 -4.5 11/02/2004 00:20:00 18.4 1.2 21.4 14.5 18.3 1.3 21.4 14.5 0.4 0 0.4 0.4 20 5 25 305 0 0 0 0 -4.3 0 -4.2 -4.5 11/02/2004 00:30:00 17.7 1.4 20.2 13 17.7 1.5 20.6 13.7 0.4 0 0.4 0.4 20 6 23 305 0 0 0 0 -4.4 0 -4 -4.5 11/02/2004 00:40:00 17.8 1.2 20.6 14.9 17.7 1.3 20.6 14.1 0.4 0 0.4 0.4 22 5 19 305 0 0 0 0 -4.5 0 -4 -4.7 11/02/2004 00:50:00 17.4 1.2 20.2 13.7 17.3 1.3 20.2 13.7 0.4 0 0.4 0.4 20 4 19 305 0 0 0 0 -4.6 0 -4 -4.7 11/02/2004 01:00:00 17.7 1.2 20.2 12.6 17.6 1.4 20.6 13 0.4 0 0.4 0.4 19 5 19 305 0 0 0 0 -4.6 0 -4.5 -4.7 11/02/2004 01:10:00 17.6 1.3 21.4 14.1 17.6 1.3 21 14.1 0.4 0 0.4 0.4 20 6 30 305 0 0 0 0 -4.7 0 -4.2 -4.9 11/02/2004 01:20:00 17.5 1.3 20.2 14.1 17.5 1.5 20.2 13.3 0.4 0 0.4 0.4 19 5 14 305 0 0 0 0 -4.8 0.1 -4.2 -4.9 11/02/2004 01:30:00 17.4 1.2 19.5 13 17.4 1.3 19.9 13 0.4 0 0.4 0.4 19 5 27 305 0 0 0 0 -4.8 0.1 -4.2 -4.9 11/02/2004 01:40:00 17 1.2 20.2 13.7 17 1.3 20.2 12.6 0.4 0 0.4 0.4 18 5 13 305 0 0 0 0 -4.8 0.1 -4.2 -4.9 11/02/2004 01:50:00 16.9 1.5 21 13.3 16.9 1.6 20.2 12.6 0.4 0 0.4 0.4 20 7 8 305 0 0 0 0 -4.9 0 -4.5 -5.1 11/02/2004 02:00:00 17.1 1.4 21 14.1 17.2 1.5 21 13 0.4 0 0.4 0.4 17 5 22 305 0 0 0 0 -5 0 -4.7 -5.1 11/02/2004 02:10:00 16.8 1.6 21.4 11.8 16.7 1.6 20.6 13 0.4 0 0.4 0.4 24 6 29 305 0 0 0 0 -5 0 -4.5 -5.3 11/02/2004 02:20:00 17.6 1.1 21 14.5 17.5 1.3 20.2 13.3 0.4 0 0.4 0.4 22 7 29 305 0 0 0 0 -5.1 0 -4.7 -5.3 11/02/2004 02:30:00 17.3 1.3 20.2 13.7 17.2 1.3 20.2 13 0.4 0 0.4 0.4 23 6 28 305 0 0 0 0 -5.1 0 -4.7 -5.3 11/02/2004 02:40:00 17.2 1.4 20.2 13.3 17.1 1.5 20.2 13.7 0.4 0 0.4 0.4 20 5 17 305 0 0 0 0 -5.1 0 -4.7 -5.3 11/02/2004 02:50:00 16.9 1.3 19.9 13.7 16.8 1.4 20.2 13 0.4 0 0.4 0.4 23 5 23 305 0 0 0 0 -5.1 0 -4.7 -5.3 11/02/2004 03:00:00 16.9 1.7 20.2 12.2 16.9 1.7 20.6 12.2 0.4 0 0.4 0.4 15 5 17 305 0 0 0 0 -5.3 0.2 -4.9 -5.8 11/02/2004 03:10:00 17.2 1.4 21 13.7 17.3 1.4 20.6 13.7 0.4 0 0.4 0.4 14 4 15 305 0 0 0 0 -5.4 0.1 -4.9 -5.6 11/02/2004 03:20:00 17.9 1.7 20.6 13.7 17.9 1.7 21 13.3 0.4 0 0.4 0.4 15 5 18 305 0 0 0 0 -5.7 0.2 -5.1 -6 11/02/2004 03:30:00 17 1.6 20.6 12.6 17 1.6 20.2 10.7 0.4 0 0.4 0.4 16 5 13 305 0 0 0 0 -5.8 0.2 -5.3 -6.2 11/02/2004 03:40:00 17.4 1.6 20.2 13.7 17.3 1.6 20.6 12.2 0.4 0 0.4 0.4 14 8 9 305 0 0 0 0 -6.1 0.2 -5.6 -6.7 11/02/2004 03:50:00 17 1.3 20.6 13.3 17 1.3 21.4 13.7 0.4 0 0.4 0.4 11 6 7 305 0 0 0 0 -6.3 0.1 -6 -6.7 11/02/2004 04:00:00 18.3 1.3 21 14.1 18.2 1.3 21.4 14.1 0.4 0 0.4 0.4 9 5 9 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/02/2004 04:10:00 17.3 1.3 20.2 13.7 17.3 1.5 20.2 13 0.4 0 0.4 0.4 12 7 7 305 0 0 0 0 -6.5 0 -6.2 -6.9 11/02/2004 04:20:00 17.3 1.5 22.1 11.8 17 1.6 21.8 12.2 0.4 0 0.4 0.4 19 8 23 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/02/2004 04:30:00 17.1 1.3 20.6 13.3 16.9 1.3 20.6 12.6 0.4 0 0.4 0.4 21 6 21 305 0 0 0 0 -6.2 0.1 -5.8 -6.7 11/02/2004 04:40:00 16.8 1.3 20.2 13.3 16.7 1.3 20.2 13.3 0.4 0 0.4 0.4 17 5 10 305 0 0 0 0 -6.2 0.1 -6 -6.7 11/02/2004 04:50:00 16.9 1.8 21 12.2 16.8 1.8 20.6 12.2 0.4 0 0.4 0.4 13 5 11 305 0 0 0 0 -6.4 0.1 -6 -6.7 11/02/2004 05:00:00 16.6 1.3 19.9 13.3 16.6 1.3 19.9 13.3 0.4 0 0.4 0.4 5 5 0 305 0 0 0 0 -6.5 0.2 -6 -6.9 11/02/2004 05:10:00 17.3 1.2 19.9 13.7 17.1 1.3 19.9 13.7 0.4 0 0.4 0.4 8 5 12 305 0 0 0 0 -6.7 0 -6.2 -6.9 11/02/2004 05:20:00 17.8 1.3 21.4 13.7 17.7 1.5 21.4 14.1 0.4 0 0.4 0.4 5 5 12 305 0 0 0 0 -6.7 0 -6.2 -6.9 11/02/2004 05:30:00 17.4 1.6 21.8 13.3 17.3 1.7 21.4 13.3 0.4 0 0.4 0.4 13 6 14 305 0 0 0 0 -6.6 0.1 -6.2 -7.1 11/02/2004 05:40:00 17.5 1.3 21 13.7 17.4 1.3 21.4 13.7 0.4 0 0.4 0.4 12 5 10 305 0 0 0 0 -6.5 0.1 -6.2 -6.9 11/02/2004 05:50:00 16.8 1.2 19.9 13.7 16.7 1.3 20.2 13.3 0.4 0 0.4 0.4 16 6 17 305 0 0 0 0 -6.3 0 -6.2 -6.7 11/02/2004 06:00:00 16.9 1.4 20.2 13.3 16.9 1.4 20.2 13 0.4 0 0.4 0.4 11 5 7 305 0 0 0 0 -6.4 0.1 -6.2 -6.7 11/02/2004 06:10:00 16.8 1.3 20.2 12.6 16.8 1.4 20.6 13 0.4 0 0.4 0.4 9 6 8 305 0 0 0 0 -6.3 0.2 -6 -6.7 11/02/2004 06:20:00 16.4 1.5 20.2 12.6 16.4 1.5 19.9 12.2 0.4 0 0.4 0.4 15 8 9 305 0 0 0 0 -6.5 0.1 -6.2 -6.9 11/02/2004 06:30:00 16.5 1.4 19.5 12.6 16.5 1.5 20.2 12.6 0.4 0 0.4 0.4 13 5 19 305 0 0 0 0 -6.4 0.1 -6 -6.7 11/02/2004 06:40:00 17.1 1.1 19.9 13.3 17.1 1.2 19.9 13.7 0.4 0 0.4 0.4 9 4 8 305 0 0 0 0 -6.2 0.2 -6 -6.7 11/02/2004 06:50:00 16.5 1.2 19.5 13 16.5 1.3 19.5 12.6 0.4 0 0.4 0.4 14 6 14 305 0 0 0 0 -6.3 0.2 -6 -6.7 11/02/2004 07:00:00 17.1 1.3 19.9 13 17.2 1.3 19.9 13.7 0.4 0 0.4 0.4 12 5 10 305 0 0 0 0 -6.2 0.1 -6 -6.7 11/02/2004 07:10:00 16.9 1.5 20.6 12.2 17 1.5 21 12.6 0.4 0 0.4 0.4 10 5 3 305 0 0 0 0 -6.2 0 -5.8 -6.4 11/02/2004 07:20:00 17.4 1.5 21 13 17.5 1.5 21.4 13.3 0.4 0 0.4 0.4 10 4 8 305 0 0 0 0 -6.2 0.2 -5.6 -6.7 11/02/2004 07:30:00 16.1 1.5 19.9 12.6 15.9 1.7 19.1 12.2 0.4 0 0.4 0.4 12 6 9 305 0 0 0 0 -6 0 -5.6 -6.2 11/02/2004 07:40:00 17 1.2 20.2 13 17.1 1.3 20.6 13.3 0.4 0 0.4 0.4 14 5 18 305 0 0 0 0 -6.2 0.2 -5.6 -6.7 11/02/2004 07:50:00 16 1.3 19.9 11.5 16 1.5 19.9 11.8 0.4 0 0.4 0.4 14 8 12 305 0 0 0 0 -6.3 0 -6 -6.7 11/02/2004 08:00:00 16.5 1.7 20.2 12.6 16.5 1.7 20.6 12.6 0.4 0 0.4 0.4 11 5 13 305 0 0 0 0 -6.2 0 -6 -6.7 11/02/2004 08:10:00 17.4 1.5 21 13 17.3 1.5 21 13 0.4 0 0.4 0.4 10 5 17 305 1 0 1 0 -5.6 0.1 -5.1 -6 11/02/2004 08:20:00 15.1 1.4 18.3 11.1 15.1 1.5 18.7 11.5 0.4 0 0.4 0.4 11 5 15 305 1 0 1 0 -5.8 0.1 -5.6 -6 11/02/2004 08:30:00 17.9 2.5 22.1 13 17.8 2.6 22.6 12.6 0.4 0 0.4 0.4 11 7 6 305 1 0 1 0 -5.6 0.2 -5.1 -6 11/02/2004 08:40:00 17.2 1.6 20.2 12.6 17.2 1.6 20.2 13 0.4 0 0.4 0.4 5 5 5 305 1 0 1 0 -5.8 0.2 -5.6 -6 11/02/2004 08:50:00 17.9 1.7 21.8 14.1 17.8 1.7 22.1 13.7 0.4 0 0.4 0.4 7 5 0 305 1 0 0 0 -5.9 0.1 -5.6 -6.2 11/02/2004 09:00:00 18 2 22.6 13 17.9 2.1 22.6 13 0.4 0 0.4 0.4 6 6 354 305 1 0 1 0 -6.1 0.2 -5.6 -6.7 11/02/2004 09:10:00 18.4 1.4 21.8 14.5 18.4 1.5 22.1 14.1 0.4 0 0.4 0.4 0 5 357 305 1 0 0 0 -5.8 0.1 -5.3 -6 11/02/2004 09:20:00 17.8 1.7 22.6 14.1 18 1.8 22.6 13.7 0.4 0 0.4 0.4 359 5 357 305 1 0 1 0 -5.8 0.1 -5.6 -6.2 11/02/2004 09:30:00 17.5 1.7 21.4 12.2 17.5 1.7 21.4 13 0.4 0 0.4 0.4 358 5 0 305 1 0 1 0 -6.1 0.1 -5.8 -6.4 11/02/2004 09:40:00 18.3 1.3 21.4 14.9 18.4 1.4 21.8 14.9 0.4 0 0.4 0.4 357 6 356 305 1 0 1 0 -5.7 0 -5.6 -6 11/02/2004 09:50:00 18.3 1.4 21.4 14.9 18.5 1.5 21.8 13.7 0.4 0 0.4 0.4 357 5 350 305 1 0 1 0 -5.6 0 -5.1 -5.8 11/02/2004 10:00:00 18.9 1.7 23.3 15.3 18.9 1.7 23.3 14.1 0.4 0 0.4 0.4 1 6 3 305 1 0 1 0 -5.3 0.1 -4.7 -5.6 11/02/2004 10:10:00 18.4 1.8 22.9 13.3 18.4 1.9 23.3 13 0.4 0 0.4 0.4 8 4 9 305 1 0 1 0 -5.6 0.2 -5.1 -6.2 11/02/2004 10:20:00 17.6 1.5 21.4 13.3 17.7 1.7 21.8 13 0.4 0 0.4 0.4 358 5 0 305 1 0 1 0 -5.7 0.2 -5.1 -6 11/02/2004 10:30:00 18.8 1.6 22.6 14.9 18.8 1.6 22.6 14.5 0.4 0 0.4 0.4 2 9 349 305 1 0 1 0 -5.3 0.1 -4.7 -5.6 11/02/2004 10:40:00 17.1 1.8 22.1 12.2 17.1 1.9 22.1 11.8 0.4 0 0.4 0.4 4 8 2 305 1 0 1 0 -5.4 0.1 -4.9 -5.8 11/02/2004 10:50:00 18.2 1.5 21.8 14.1 18.3 1.5 22.6 14.1 0.4 0 0.4 0.4 1 6 354 305 1 0 1 0 -5.1 0 -4.7 -5.6 11/02/2004 11:00:00 18.5 1.7 22.1 13.7 18.5 1.7 22.6 13 0.4 0 0.4 0.4 6 7 5 305 1 0 1 0 -5.1 0.1 -4.7 -5.6 11/02/2004 11:10:00 19.5 1.5 22.9 15.3 19.4 1.5 22.9 15.3 0.4 0 0.4 0.4 3 6 7 305 1 0 1 0 -4.9 0.1 -4.7 -5.1 11/02/2004 11:20:00 20.5 2 25.2 16.4 20.4 2 25.6 16.1 0.4 0 0.4 0.4 2 8 357 305 1 0 1 0 -4.9 0.1 -4.5 -5.1 11/02/2004 11:30:00 18.9 1.7 22.1 13 18.9 1.8 22.9 14.1 0.4 0 0.4 0.4 356 6 351 305 1 0 1 0 -4.9 0.1 -4.5 -5.1 11/02/2004 11:40:00 19.3 1.5 23.3 14.9 19.4 1.5 24 15.6 0.4 0 0.4 0.4 355 6 357 305 1 0 1 0 -5 0 -4.7 -5.3 11/02/2004 11:50:00 20.4 1.4 25.6 16.8 20.4 1.5 24.8 15.6 0.4 0 0.4 0.4 356 5 0 305 1 0 1 0 -5.2 0.1 -4.9 -5.6 11/02/2004 12:00:00 19.7 1.7 26 15.3 19.8 1.7 25.6 15.6 0.4 0 0.4 0.4 358 7 12 305 1 0 1 0 -5.1 0.1 -4.7 -5.3 11/02/2004 12:10:00 20.2 1.7 24 14.9 20.2 1.9 24.8 14.9 0.4 0 0.4 0.4 1 6 358 305 1 0 1 0 -5.2 0.2 -4.7 -5.6 11/02/2004 12:20:00 19.7 1.8 23.7 14.9 19.7 1.8 23.7 14.5 0.4 0 0.4 0.4 6 6 353 305 1 0 1 0 -4.7 0.1 -4.2 -4.9 11/02/2004 12:30:00 20.2 1.6 24.4 16.1 20.2 1.7 23.7 16.1 0.4 0 0.4 0.4 7 5 5 305 1 0 1 0 -4.7 0 -4.5 -4.9 11/02/2004 12:40:00 19.3 1.3 23.3 15.3 19.3 1.4 23.3 14.9 0.4 0 0.4 0.4 7 6 10 305 0 0 0 0 -4.7 0.1 -4.5 -4.9 11/02/2004 12:50:00 20.1 2.3 25.6 14.5 20.1 2.3 26 14.9 0.4 0 0.4 0.4 6 4 5 305 0 0 0 0 -4.9 0.1 -4.5 -5.1 11/02/2004 13:00:00 18.8 1.8 24 13.7 18.8 1.8 23.7 14.1 0.4 0 0.4 0.4 3 5 4 305 0 0 0 0 -4.9 0.1 -4.5 -5.1 11/02/2004 13:10:00 19.1 1.9 22.9 13.3 19 1.9 23.3 13.7 0.4 0 0.4 0.4 9 6 6 305 0 0 0 0 -4.6 0 -4.2 -4.9 11/02/2004 13:20:00 19.1 2 24 13.3 19.1 2 24 12.6 0.4 0 0.4 0.4 2 6 358 305 0 0 0 0 -4.6 0.1 -4.5 -5.1 11/02/2004 13:30:00 19.8 2.2 24.8 14.5 19.8 2.2 24 14.5 0.4 0 0.4 0.4 359 5 356 305 0 0 0 0 -5 0 -4.7 -5.1 11/02/2004 13:40:00 19.5 1.7 23.3 13.7 19.5 1.8 22.9 14.1 0.4 0 0.4 0.4 2 6 356 305 0 0 0 0 -4.8 0.1 -4.7 -4.9 11/02/2004 13:50:00 19.3 2.5 25.6 13.7 19.3 2.6 26.8 13.7 0.4 0 0.4 0.4 1 7 352 305 0 0 0 0 -4.9 0.1 -4.5 -5.1 11/02/2004 14:00:00 19.4 2.1 24.8 14.9 19.4 2.1 24.4 14.5 0.4 0 0.4 0.4 358 6 0 305 0 0 0 0 -4.9 0 -4.7 -5.1 11/02/2004 14:10:00 18.3 1.9 22.1 14.1 18.3 1.8 22.1 13.7 0.4 0 0.4 0.4 5 5 11 305 0 0 0 0 -5.1 0.2 -4.7 -5.6 11/02/2004 14:20:00 18.4 1.7 22.6 14.5 18.4 1.8 22.1 14.5 0.4 0 0.4 0.4 1 5 358 305 0 0 0 0 -5.4 0.3 -4.9 -6 11/02/2004 14:30:00 18.7 1.8 22.6 13.7 18.6 1.9 22.6 13.7 0.4 0 0.4 0.4 11 6 11 305 0 0 0 0 -6.1 0.2 -5.6 -6.7 11/02/2004 14:40:00 16.9 1.5 20.2 12.2 16.8 1.5 21 13 0.4 0 0.4 0.4 9 6 356 305 0 0 0 0 -6.3 0.1 -5.8 -6.7 11/02/2004 14:50:00 17.1 1.9 21.8 11.8 17 1.9 22.1 13 0.4 0 0.4 0.4 359 6 357 305 0 0 0 0 -5.9 0.1 -5.6 -6.2 11/02/2004 15:00:00 17.4 1.5 20.6 13.3 17.5 1.6 21.4 13 0.4 0 0.4 0.4 355 5 356 305 0 0 1 0 -5.7 0.2 -5.1 -6.2 11/02/2004 15:10:00 18.2 1.7 23.3 14.1 18.4 1.8 23.7 14.1 0.4 0 0.4 0.4 355 5 348 305 1 0 0 0 -5.5 0 -5.3 -5.8 11/02/2004 15:20:00 18.3 1.9 22.1 13 18.4 1.9 22.6 13.3 0.4 0 0.4 0.4 356 7 356 305 1 0 1 0 -5.5 0 -5.1 -5.8 11/02/2004 15:30:00 18.4 2 22.6 13.3 18.5 2 22.9 13.7 0.4 0 0.4 0.4 355 9 350 305 1 0 1 0 -5.4 0.2 -4.9 -5.8 11/02/2004 15:40:00 18.9 1.7 22.9 13.3 18.9 1.7 23.3 14.1 0.4 0 0.4 0.4 353 6 354 305 1 0 1 0 -5 0.1 -4.7 -5.6 11/02/2004 15:50:00 18 1.7 22.1 14.1 18.2 1.8 22.6 14.1 0.4 0 0.4 0.4 354 6 355 305 1 0 1 0 -5.4 0.2 -4.9 -5.8 11/02/2004 16:00:00 19.4 1.9 23.7 14.9 19.5 2 24.4 14.9 0.4 0 0.4 0.4 352 5 352 305 1 0 1 0 -5.5 0.1 -5.1 -5.8 11/02/2004 16:10:00 18.4 1.7 23.3 14.1 18.6 1.9 23.7 13 0.4 0 0.4 0.4 353 5 354 305 1 0 1 0 -5.7 0.1 -5.6 -6 11/02/2004 16:20:00 19.5 1.6 24 14.9 19.7 1.6 23.7 14.9 0.4 0 0.4 0.4 351 5 348 305 1 0 1 0 -5.7 0.2 -5.1 -6 11/02/2004 16:30:00 18.9 1.5 22.6 14.9 18.9 1.5 22.6 14.9 0.4 0 0.4 0.4 349 5 343 305 1 0 1 0 -5.6 0.2 -5.1 -6 11/02/2004 16:40:00 18.8 1.8 22.6 13 18.8 1.8 22.9 14.1 0.4 0 0.4 0.4 349 5 346 305 1 0 1 0 -5.9 0.1 -5.6 -6.2 11/02/2004 16:50:00 19.3 1.3 22.6 16.1 19.5 1.4 22.9 15.3 0.4 0 0.4 0.4 353 5 352 305 1 0 1 0 -5.8 0.1 -5.6 -6 11/02/2004 17:00:00 18.8 1.7 22.9 13.3 18.8 1.8 24 14.5 0.4 0 0.4 0.4 351 6 351 305 1 0 1 0 -5.7 0.1 -5.3 -6 11/02/2004 17:10:00 20 1.7 24.8 14.5 20.1 1.9 25.6 14.9 0.4 0 0.4 0.4 353 5 354 305 1 0 1 0 -5.5 0 -5.1 -5.8 11/02/2004 17:20:00 20.4 1.5 24.4 16.1 20.3 1.5 23.7 16.1 0.4 0 0.4 0.4 355 4 357 305 1 0 1 0 -5.4 0 -5.1 -5.6 11/02/2004 17:30:00 20.4 1.8 24 15.6 20.4 1.8 23.7 15.6 0.4 0 0.4 0.4 355 5 350 305 1 0 1 0 -5.3 0 -5.1 -5.6 11/02/2004 17:40:00 19.3 2 24 14.5 19.4 2 24.8 14.9 0.4 0 0.4 0.4 352 5 343 305 1 0 1 0 -5.3 0 -4.9 -5.6 11/02/2004 17:50:00 19.7 2 24 14.1 19.8 2.1 24.4 14.9 0.4 0 0.4 0.4 354 5 350 305 1 0 1 0 -5.2 0.1 -4.7 -5.6 11/02/2004 18:00:00 20.4 1.6 24.4 16.1 20.3 1.8 24.8 15.3 0.4 0 0.4 0.4 355 5 353 305 1 0 1 0 -5.1 0 -4.7 -5.3 11/02/2004 18:10:00 20 1.7 23.7 16.1 20.2 1.7 24.8 15.6 0.4 0 0.4 0.4 352 5 350 305 1 0 1 0 -5.2 0 -4.7 -5.6 11/02/2004 18:20:00 18.9 1.7 22.6 13.7 19 1.7 22.9 14.5 0.4 0 0.4 0.4 352 5 353 305 1 0 1 0 -5 0 -4.9 -5.1 11/02/2004 18:30:00 20.3 2.4 26.3 15.3 20.4 2.5 26.3 14.9 0.4 0 0.4 0.4 356 6 358 305 1 0 1 0 -4.8 0 -4.5 -5.1 11/02/2004 18:40:00 20.4 2.2 25.6 14.9 20.3 2.2 25.2 15.3 0.4 0 0.4 0.4 357 6 3 305 1 0 1 0 -4.6 0 -4.5 -4.9 11/02/2004 18:50:00 20.3 1.9 24.8 14.9 20.3 2.1 25.6 14.5 0.4 0 0.4 0.4 357 6 357 305 1 0 1 0 -4.6 0.1 -4.5 -4.9 11/02/2004 19:00:00 20.1 1.9 24 14.9 20.1 2.1 25.6 14.1 0.4 0 0.4 0.4 354 6 355 305 1 0 1 0 -4.6 0.1 -4.2 -4.9 11/02/2004 19:10:00 19.9 2.1 25.6 15.6 20 2.1 25.6 14.9 0.4 0 0.4 0.4 355 4 352 305 1 0 1 0 -4.5 0 -4.2 -4.7 11/02/2004 19:20:00 21 1.9 25.2 15.3 20.9 1.9 25.2 14.9 0.4 0 0.4 0.4 1 5 8 305 1 0 1 0 -4.5 0 -4.2 -4.7 11/02/2004 19:30:00 20.8 1.7 25.2 15.3 20.7 1.8 25.2 15.6 0.4 0 0.4 0.4 5 5 0 305 1 0 1 0 -4.4 0 -4 -4.7 11/02/2004 19:40:00 20.6 1.7 24.4 15.6 20.6 1.7 24.4 15.6 0.4 0 0.4 0.4 4 5 2 305 1 0 1 0 -4.4 0 -4.2 -4.7 11/02/2004 19:50:00 20 1.8 23.3 14.1 20 1.8 24.4 13.3 0.4 0 0.4 0.4 1 6 354 305 1 0 1 0 -4.5 0.2 -4 -4.9 11/02/2004 20:00:00 19.5 1.7 23.7 14.1 19.6 1.7 24 14.9 0.4 0 0.4 0.4 1 6 0 305 1 0 1 0 -4.6 0.2 -4 -4.9 11/02/2004 20:10:00 19.7 1.9 24.4 14.1 19.9 2 25.2 13.7 0.4 0 0.4 0.4 359 5 355 305 1 0 1 0 -4.7 0.2 -3.8 -4.9 11/02/2004 20:20:00 19.5 1.7 23.7 15.3 19.7 1.8 23.7 14.1 0.4 0 0.4 0.4 354 5 353 305 1 0 1 0 -4.9 0.1 -4.5 -5.1 11/02/2004 20:30:00 19 1.6 23.7 14.9 19.1 1.7 24.4 14.1 0.4 0 0.4 0.4 354 5 345 305 1 0 1 0 -5.4 0.2 -4.7 -5.8 11/02/2004 20:40:00 18.8 1.7 22.9 14.9 18.8 1.8 23.3 15.3 0.4 0 0.4 0.4 357 6 353 305 1 0 1 0 -5.5 0 -5.1 -5.8 11/02/2004 20:50:00 19.4 1.8 23.3 13.7 19.3 2 24.4 13.7 0.4 0 0.4 0.4 356 6 2 305 1 0 1 0 -5.3 0.1 -4.7 -5.8 11/02/2004 21:00:00 18.9 1.9 24.4 13.3 19.1 2.1 24.8 13 0.4 0 0.4 0.4 354 6 349 305 1 0 1 0 -5.3 0.1 -4.9 -5.6 11/02/2004 21:10:00 18.7 1.9 22.6 13 18.9 1.9 22.9 14.1 0.4 0 0.4 0.4 354 6 352 305 1 0 1 0 -5.1 0 -4.7 -5.3 11/02/2004 21:20:00 18 1.9 21.8 13.3 18.1 1.9 21.8 12.2 0.4 0 0.4 0.4 354 6 356 305 1 0 1 0 -5.1 0.1 -4.7 -5.6 11/02/2004 21:30:00 19.1 1.5 22.9 14.9 19.2 1.5 22.9 15.6 0.4 0 0.4 0.4 353 5 348 305 1 0 1 0 -5.1 0 -4.7 -5.6 11/02/2004 21:40:00 19.2 1.4 22.9 15.6 19.3 1.5 23.3 15.3 0.4 0 0.4 0.4 351 6 348 305 1 0 1 0 -5.1 0.1 -4.7 -5.6 11/02/2004 21:50:00 18.3 1.7 22.9 13.7 18.5 1.7 23.3 13.7 0.4 0 0.4 0.4 351 5 350 305 1 0 1 0 -5.2 0.2 -4.9 -5.6 11/02/2004 22:00:00 18.5 1.4 22.1 14.1 18.7 1.4 22.1 13.7 0.4 0 0.4 0.4 348 4 348 305 1 0 1 0 -5.5 0 -5.1 -5.6 11/02/2004 22:10:00 18.5 1.3 21.4 14.5 18.7 1.3 21.8 14.9 0.4 0 0.4 0.4 352 5 345 305 1 0 1 0 -5.4 0.1 -5.1 -5.8 11/02/2004 22:20:00 17.3 1.6 21 13.3 17.5 1.7 21 13 0.4 0 0.4 0.4 348 5 342 305 1 0 1 0 -5.6 0.1 -5.1 -5.8 11/02/2004 22:30:00 18.5 1.4 21.8 14.5 18.7 1.5 21.8 14.9 0.4 0 0.4 0.4 350 5 354 305 1 0 1 0 -5.6 0 -5.6 -5.8 11/02/2004 22:40:00 17.8 1.2 22.1 14.9 18 1.3 21.8 14.5 0.4 0 0.4 0.4 349 5 348 305 1 0 1 0 -5.8 0.1 -5.6 -6 11/02/2004 22:50:00 17.3 1.3 20.6 13.3 17.6 1.3 20.6 13.7 0.4 0 0.4 0.4 351 5 358 305 1 0 1 0 -5.6 0.1 -5.3 -6 11/02/2004 23:00:00 17.8 1.4 21.8 14.9 17.9 1.5 22.9 14.1 0.4 0 0.4 0.4 350 5 357 305 1 0 1 0 -5.8 0.1 -5.3 -6 11/02/2004 23:10:00 17.9 1.6 21.4 13.3 18.1 1.7 21.8 13.7 0.4 0 0.4 0.4 350 6 346 305 1 0 1 0 -5.6 0 -5.3 -5.8 11/02/2004 23:20:00 16.7 1.4 19.9 13 16.9 1.5 19.9 13.3 0.4 0 0.4 0.4 353 5 347 305 2 0 1 0 -5.4 0 -5.1 -5.6 11/02/2004 23:30:00 16.6 1.5 19.5 11.5 16.7 1.7 20.2 12.2 0.4 0 0.4 0.4 350 5 351 305 2 0 2 0 -5.3 0.1 -4.9 -5.6 11/02/2004 23:40:00 16.9 1.3 20.2 13 17 1.3 20.2 13 0.4 0 0.4 0.4 350 6 343 305 2 0 2 0 -5.6 0 -5.6 -5.8 11/02/2004 23:50:00 16.2 1.6 20.2 11.8 16.3 1.7 20.6 11.1 0.4 0 0.4 0.4 349 5 351 305 2 0 2 0 -5.7 0.2 -5.3 -6 11/03/2004 00:00:00 16.5 2.2 20.6 11.5 16.7 2.3 21 11.5 0.4 0 0.4 0.4 349 5 350 305 2 0 1 0 -5.7 0.1 -5.6 -6.2 11/03/2004 00:10:00 16.7 1.5 20.6 13 16.9 1.5 20.6 12.6 0.4 0 0.4 0.4 347 5 353 305 1 0 1 0 -5.9 0 -5.8 -6.2 11/03/2004 00:20:00 17 1.3 20.2 13 17.2 1.5 21.4 13 0.4 0 0.4 0.4 349 6 347 305 1 0 1 0 -5.6 0.1 -5.6 -6 11/03/2004 00:30:00 17.2 1.3 20.6 13.3 17.3 1.5 21 12.6 0.4 0 0.4 0.4 346 5 354 305 1 0 2 0 -5.6 0 -5.3 -5.8 11/03/2004 00:40:00 16.5 1.7 19.5 12.2 16.6 1.7 20.2 13 0.4 0 0.4 0.4 352 6 2 305 1 0 1 0 -5.3 0.1 -4.9 -5.6 11/03/2004 00:50:00 16.4 1.3 19.5 11.8 16.5 1.4 20.2 12.2 0.4 0 0.4 0.4 349 6 351 305 2 0 1 0 -5.4 0 -5.1 -5.8 11/03/2004 01:00:00 16.8 1.2 19.5 13 16.9 1.3 19.5 13.7 0.4 0 0.4 0.4 344 6 348 305 2 0 2 0 -5.5 0 -5.1 -5.6 11/03/2004 01:10:00 16.9 1.3 19.9 12.2 17.2 1.5 20.6 13 0.4 0 0.4 0.4 343 5 343 305 1 0 1 0 -5.5 0 -5.3 -5.8 11/03/2004 01:20:00 17.3 1.5 21.8 12.6 17.4 1.7 21.8 13.3 0.4 0 0.4 0.4 342 5 337 305 1 0 1 0 -5.5 0 -5.1 -5.8 11/03/2004 01:30:00 17.6 1.5 20.6 14.1 17.8 1.6 21 13.3 0.4 0 0.4 0.4 347 4 347 305 1 0 1 0 -5.5 0 -5.1 -5.8 11/03/2004 01:40:00 17.6 1.4 20.2 13.7 17.7 1.5 20.6 13.7 0.4 0 0.4 0.4 347 5 352 305 1 0 1 0 -5.5 0 -5.1 -5.8 11/03/2004 01:50:00 17.3 1.9 21.4 12.6 17.4 1.9 21.8 12.6 0.4 0 0.4 0.4 346 6 337 305 1 0 1 0 -5.5 0.1 -5.1 -5.8 11/03/2004 02:00:00 17.3 1.8 21.8 11.8 17.4 1.8 22.1 12.6 0.4 0 0.4 0.4 344 5 346 305 1 0 1 0 -5.3 0.1 -4.9 -5.6 11/03/2004 02:10:00 17.7 1.7 22.9 13.3 17.8 1.9 23.3 13.7 0.4 0 0.4 0.4 346 6 340 305 1 0 1 0 -5.5 0 -5.3 -5.8 11/03/2004 02:20:00 17.4 1.3 21 13.3 17.6 1.3 20.6 14.1 0.4 0 0.4 0.4 348 5 351 305 1 0 1 0 -5.5 0 -5.3 -5.8 11/03/2004 02:30:00 17.2 1.5 21 13 17.5 1.5 20.6 13.3 0.4 0 0.4 0.4 348 5 337 305 1 0 1 0 -5.6 0.1 -5.1 -6 11/03/2004 02:40:00 16.6 1.3 19.5 12.2 16.8 1.5 20.2 11.8 0.4 0 0.4 0.4 347 5 351 305 1 0 1 0 -5.5 0 -5.1 -5.8 11/03/2004 02:50:00 16.3 1.2 19.5 13.3 16.4 1.3 20.2 13 0.4 0 0.4 0.4 346 5 354 305 1 0 1 0 -5.4 0 -5.1 -5.6 11/03/2004 03:00:00 16.9 1.3 20.6 13 17 1.4 21 13 0.4 0 0.4 0.4 342 5 341 305 1 0 1 0 -5.4 0.1 -4.9 -5.6 11/03/2004 03:10:00 17 1.4 19.5 13.3 17.3 1.5 20.2 12.2 0.4 0 0.4 0.4 346 5 340 305 1 0 1 0 -5.5 0 -4.9 -5.6 11/03/2004 03:20:00 17 1.1 20.2 12.6 17.3 1.2 20.2 13.7 0.4 0 0.4 0.4 344 5 341 305 1 0 1 0 -5.4 0.1 -4.9 -5.6 11/03/2004 03:30:00 17.2 1.3 19.9 12.6 17.4 1.4 20.6 13.3 0.4 0 0.4 0.4 342 5 336 305 1 0 1 0 -5.5 0 -4.9 -5.8 11/03/2004 03:40:00 16.7 1.7 21 12.6 16.9 1.8 20.6 12.6 0.4 0 0.4 0.4 344 5 346 305 1 0 1 0 -5.6 0.1 -4.9 -5.8 11/03/2004 03:50:00 16 1.5 18.7 10.7 16.3 1.7 19.9 10.7 0.4 0 0.4 0.4 347 5 338 305 1 0 1 0 -5.5 0.1 -4.7 -5.8 11/03/2004 04:00:00 15.5 1.6 19.1 11.1 15.8 1.7 19.5 10.7 0.4 0 0.4 0.4 343 6 336 305 1 0 1 0 -5.4 0.1 -5.1 -5.8 11/03/2004 04:10:00 16.6 1.6 21 12.2 16.8 1.7 21.4 12.2 0.4 0 0.4 0.4 342 5 350 305 1 0 1 0 -5.2 0 -4.9 -5.3 11/03/2004 04:20:00 16.9 1.5 20.2 13.3 17.2 1.5 21 13 0.4 0 0.4 0.4 343 6 334 305 1 0 1 0 -5.3 0 -5.1 -5.6 11/03/2004 04:30:00 16.7 1.3 19.5 13 16.9 1.5 19.9 13.3 0.4 0 0.4 0.4 344 5 344 305 1 0 1 0 -5.4 0 -5.1 -5.8 11/03/2004 04:40:00 16.7 1.6 20.2 12.2 16.9 1.7 20.6 11.8 0.4 0 0.4 0.4 344 5 344 305 1 0 1 0 -5.3 0 -5.1 -5.6 11/03/2004 04:50:00 17.2 1.5 20.6 13 17.5 1.5 21.4 13.3 0.4 0 0.4 0.4 344 5 344 305 1 0 1 0 -5.5 0 -5.1 -5.8 11/03/2004 05:00:00 17.2 1.4 20.6 13.3 17.4 1.5 21 13.3 0.4 0 0.4 0.4 347 6 348 305 1 0 1 0 -5.5 0 -4.9 -5.8 11/03/2004 05:10:00 17.9 1.6 21 13.7 18.1 1.7 21.8 13.7 0.4 0 0.4 0.4 345 5 350 305 1 0 1 0 -5.5 0 -5.1 -5.8 11/03/2004 05:20:00 17.2 1.8 21 12.2 17.5 1.9 22.1 13 0.4 0 0.4 0.4 344 5 346 305 1 0 1 0 -5.5 0.1 -4.7 -5.8 11/03/2004 05:30:00 16.6 1.5 20.2 11.8 16.8 1.5 20.6 13 0.4 0 0.4 0.4 347 7 345 305 1 0 1 0 -5.5 0 -4.7 -5.8 11/03/2004 05:40:00 16.5 1.7 20.2 12.2 16.8 1.7 21 12.6 0.4 0 0.4 0.4 344 6 350 305 1 0 1 0 -5.6 0 -5.3 -5.8 11/03/2004 05:50:00 16.6 1.4 19.9 13.3 16.9 1.5 20.2 12.6 0.4 0 0.4 0.4 350 6 340 305 0 0 0 0 -5.5 0 -4.9 -5.8 11/03/2004 06:00:00 16.5 1.5 19.9 12.2 16.7 1.7 19.9 12.6 0.4 0 0.4 0.4 350 5 349 305 0 0 0 0 -5.5 0 -4.7 -5.8 11/03/2004 06:10:00 16.6 1.5 22.1 12.6 16.8 1.7 22.9 11.8 0.4 0 0.4 0.4 348 6 350 305 0 0 0 0 -5.5 0 -4.9 -5.8 11/03/2004 06:20:00 16.9 1.2 19.9 13.3 17.1 1.4 20.6 13 0.4 0 0.4 0.4 346 5 344 305 0 0 0 0 -5.5 0 -4.7 -5.8 11/03/2004 06:30:00 16.4 1.6 19.9 12.2 16.6 1.7 20.6 12.2 0.4 0 0.4 0.4 349 6 346 305 0 0 0 0 -5.6 0 -5.1 -5.8 11/03/2004 06:40:00 16.5 1.5 19.5 11.5 16.7 1.7 20.6 11.8 0.4 0 0.4 0.4 344 6 342 305 0 0 0 0 -5.6 0 -4.9 -5.8 11/03/2004 06:50:00 16.2 1.5 19.9 12.2 16.5 1.5 19.9 12.2 0.4 0 0.4 0.4 346 4 337 305 0 0 0 0 -5.7 0.1 -5.1 -6 11/03/2004 07:00:00 15.9 1.5 18.7 12.2 16.2 1.5 19.5 12.6 0.4 0 0.4 0.4 346 5 338 305 0 0 0 0 -5.6 0.2 -4.9 -6 11/03/2004 07:10:00 16.7 1.3 19.5 13 17.1 1.5 19.9 13 0.4 0 0.4 0.4 344 5 341 305 0 0 0 0 -5.9 0.1 -5.3 -6 11/03/2004 07:20:00 16.1 1.5 19.9 12.2 16.3 1.7 20.2 11.8 0.4 0 0.4 0.4 342 5 345 305 0 0 0 0 -5.8 0 -5.1 -6 11/03/2004 07:30:00 16.8 1.2 19.9 13.3 17 1.4 20.2 13 0.4 0 0.4 0.4 343 6 330 305 0 0 0 0 -5.8 0.1 -5.3 -6 11/03/2004 07:40:00 16.2 1.2 19.1 13.3 16.4 1.3 19.5 13 0.4 0 0.4 0.4 344 6 344 305 0 0 0 0 -5.7 0.1 -5.1 -6 11/03/2004 07:50:00 16.2 1.2 18.7 13 16.4 1.2 19.5 12.6 0.4 0 0.4 0.4 346 5 353 305 0 0 0 0 -5.8 0.1 -5.3 -6 11/03/2004 08:00:00 16.3 1.6 18.7 11.5 16.5 1.7 19.5 11.5 0.4 0 0.4 0.4 345 5 342 305 0 0 0 0 -5.9 0 -5.6 -6 11/03/2004 08:10:00 16 1.5 19.1 12.2 16.2 1.7 20.2 12.2 0.4 0 0.4 0.4 349 5 353 305 0 0 0 0 -5.8 0.1 -5.6 -6 11/03/2004 08:20:00 16.1 1.4 19.1 12.2 16.5 1.4 19.9 13 0.4 0 0.4 0.4 348 5 350 305 0 0 0 0 -5.9 0.1 -5.6 -6.2 11/03/2004 08:30:00 15.2 1.4 18.3 11.1 15.6 1.5 18.7 10.3 0.4 0 0.4 0.4 346 5 348 305 0 0 0 0 -5.8 0.1 -5.6 -6.2 11/03/2004 08:40:00 13.8 1.2 16.4 10.7 14.1 1.3 17.2 10.7 0.4 0 0.4 0.4 337 7 336 305 0 0 0 0 -6 0 -5.8 -6.2 11/03/2004 08:50:00 14.3 1.6 18.7 10.7 14.5 1.6 19.1 11.1 0.4 0 0.4 0.4 339 6 351 305 0 0 0 0 -5.9 0 -5.6 -6.2 11/03/2004 09:00:00 14.9 1.2 17.9 11.5 15.1 1.3 17.9 11.8 0.4 0 0.4 0.4 348 7 349 305 0 0 0 0 -5.9 0.1 -5.3 -6.2 11/03/2004 09:10:00 14 1.5 19.1 10.3 14.3 1.7 19.5 10.3 0.4 0 0.4 0.4 338 5 341 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 09:20:00 14.1 1.2 16.8 11.1 14.4 1.3 17.6 10.3 0.4 0 0.4 0.4 341 6 336 305 0 0 0 0 -5.9 0.1 -5.3 -6.2 11/03/2004 09:30:00 13.5 1.7 18.3 9.1 13.8 1.7 18.3 8.8 0.4 0 0.4 0.4 337 5 330 305 0 0 0 0 -5.9 0.1 -5.6 -6 11/03/2004 09:40:00 13.9 1.3 16.8 10.7 14.1 1.5 17.2 10.7 0.4 0 0.4 0.4 340 5 346 305 0 0 0 0 -6 0 -5.3 -6.2 11/03/2004 09:50:00 13.5 1.1 16.4 11.1 13.7 1.3 17.2 10.3 0.4 0 0.4 0.4 339 6 333 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 10:00:00 13.2 1.4 16.8 9.9 13.5 1.5 17.6 9.9 0.4 0 0.4 0.4 338 6 333 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/03/2004 10:10:00 13.4 1.1 17.2 9.5 13.7 1.2 17.9 9.5 0.4 0 0.4 0.4 336 5 329 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/03/2004 10:20:00 12.8 1.4 16.4 8.4 13.1 1.4 16.4 8.8 0.4 0 0.4 0.4 335 6 324 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/03/2004 10:30:00 13 1 16.4 9.9 13.2 1 16.1 10.7 0.4 0 0.4 0.4 331 4 332 305 0 0 0 0 -6.2 0 -6 -6.4 11/03/2004 10:40:00 12.4 1.3 16.1 8.8 12.6 1.3 15.6 8.8 0.4 0 0.4 0.4 333 5 337 305 0 0 0 0 -6.2 0 -6 -6.4 11/03/2004 10:50:00 12.9 1.3 16.8 9.9 13 1.4 16.8 9.9 0.4 0 0.4 0.4 331 5 332 305 0 0 0 0 -6.2 0 -6 -6.4 11/03/2004 11:00:00 13.2 1.2 16.1 10.3 13.4 1.3 16.1 9.9 0.4 0 0.4 0.4 333 4 332 305 0 0 0 0 -6.1 0 -5.6 -6.4 11/03/2004 11:10:00 12.4 1.2 15.3 9.9 12.6 1.3 15.6 9.5 0.4 0 0.4 0.4 338 7 332 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 11:20:00 12.7 1.1 15.6 10.3 12.9 1.1 16.1 10.3 0.4 0 0.4 0.4 337 8 335 305 0 0 0 0 -6.1 0 -5.3 -6.2 11/03/2004 11:30:00 12.4 1.1 15.3 9.5 12.6 1.2 16.1 9.9 0.4 0 0.4 0.4 335 5 338 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 11:40:00 12.9 1.2 16.1 10.3 13.1 1.3 16.1 9.5 0.4 0 0.4 0.4 332 6 328 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 11:50:00 12.7 1.3 15.3 9.1 12.8 1.3 15.3 9.1 0.4 0 0.4 0.4 333 5 332 305 0 0 0 0 -6.1 0 -5.8 -6.4 11/03/2004 12:00:00 12.7 1.2 16.4 9.9 12.9 1.3 16.1 9.1 0.4 0 0.4 0.4 335 6 329 305 0 0 0 0 -6.1 0 -5.6 -6.4 11/03/2004 12:10:00 12.2 1.2 14.9 8.8 12.5 1.2 15.3 9.5 0.4 0 0.4 0.4 333 5 331 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 12:20:00 11.8 1 14.1 9.1 12 1 14.5 9.1 0.4 0 0.4 0.4 334 6 338 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 12:30:00 11.9 1.2 14.9 8.8 11.9 1.2 15.3 8.8 0.4 0 0.4 0.4 332 6 330 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 12:40:00 11.6 1.1 14.5 8.8 11.9 1.2 15.6 9.1 0.4 0 0.4 0.4 335 6 332 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 12:50:00 11.7 1.3 14.5 8.4 12 1.3 14.5 8.8 0.4 0 0.4 0.4 336 6 315 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 13:00:00 11.9 1 14.5 9.5 12.1 1 14.5 9.1 0.4 0 0.4 0.4 336 5 330 305 0 0 0 0 -5.9 0 -5.3 -6 11/03/2004 13:10:00 11.6 1.3 15.3 9.1 11.9 1.3 16.1 9.1 0.4 0 0.4 0.4 337 5 339 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 13:20:00 11.7 1.2 14.5 8.8 11.9 1.2 15.6 9.1 0.4 0 0.4 0.4 336 6 341 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 13:30:00 11.7 1.1 14.1 9.1 11.9 1.2 15.3 9.5 0.4 0 0.4 0.4 333 5 332 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 13:40:00 11.5 1.1 14.1 8.4 11.7 1.1 15.3 8.4 0.4 0 0.4 0.4 337 6 336 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 13:50:00 11.2 1.3 14.5 7.6 11.4 1.4 15.3 8 0.4 0 0.4 0.4 332 5 333 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 14:00:00 11.3 1.2 14.5 8.8 11.6 1.3 14.5 9.1 0.4 0 0.4 0.4 337 6 333 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 14:10:00 11.4 1 13.7 8.8 11.6 1.1 14.1 8.8 0.4 0 0.4 0.4 335 5 332 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 14:20:00 11.4 1.2 14.5 8.4 11.6 1.3 14.5 8 0.4 0 0.4 0.4 336 6 336 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 14:30:00 11.6 1.1 14.1 8.8 11.8 1.1 14.9 9.1 0.4 0 0.4 0.4 336 6 326 305 0 0 0 0 -6 0 -5.8 -6.2 11/03/2004 14:40:00 10.9 1 14.1 8.4 11.2 1 14.1 8.4 0.4 0 0.4 0.4 335 7 326 305 0 0 0 0 -6 0 -5.8 -6.2 11/03/2004 14:50:00 11.1 1.2 14.5 8.8 11.3 1.3 14.1 8 0.4 0 0.4 0.4 334 6 338 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 15:00:00 11.2 1.1 14.5 8 11.4 1.2 14.5 8.8 0.4 0 0.4 0.4 334 7 330 305 0 0 0 0 -5.9 0 -5.6 -6.2 11/03/2004 15:10:00 11.4 1.2 14.5 8.4 11.7 1.2 14.9 9.1 0.4 0 0.4 0.4 336 4 332 305 0 0 0 0 -5.8 0 -5.3 -6 11/03/2004 15:20:00 11.2 1.1 14.9 8.8 11.5 1.2 14.5 8.8 0.4 0 0.4 0.4 337 8 337 305 0 0 0 0 -5.9 0.1 -5.6 -6 11/03/2004 15:30:00 11.2 1.3 14.5 8.4 11.4 1.3 14.5 8.4 0.4 0 0.4 0.4 337 8 332 305 0 0 0 0 -5.9 0 -5.6 -6 11/03/2004 15:40:00 11 1.3 16.1 8 11.2 1.3 16.1 8 0.4 0 0.4 0.4 334 7 330 305 0 0 0 0 -5.9 0.1 -5.6 -6 11/03/2004 15:50:00 10.7 1.1 14.1 7.6 10.9 1.2 14.5 8 0.4 0 0.4 0.4 336 7 347 305 0 0 0 0 -5.9 0 -5.6 -6.2 11/03/2004 16:00:00 10.3 1.2 13 7.6 10.7 1.2 13.7 8 0.4 0 0.4 0.4 341 6 339 305 0 0 0 0 -5.9 0.1 -5.6 -6.2 11/03/2004 16:10:00 10.3 1 13.3 8 10.7 1.1 13.7 8 0.4 0 0.4 0.4 341 5 339 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 16:20:00 10.5 1.4 14.5 7.2 10.8 1.5 14.5 7.6 0.4 0 0.4 0.4 339 5 333 305 0 0 0 0 -5.9 0.1 -5.6 -6.2 11/03/2004 16:30:00 11 1.2 13.7 8 11.3 1.2 13.7 8.4 0.4 0 0.4 0.4 337 5 334 305 0 0 0 0 -5.9 0 -5.6 -6 11/03/2004 16:40:00 10.8 1 13.3 8.4 11.1 1 13.7 8 0.4 0 0.4 0.4 344 6 346 305 0 0 0 0 -5.9 0.1 -5.6 -6 11/03/2004 16:50:00 11 0.9 13 8.4 11.2 1 14.1 8.4 0.4 0 0.4 0.4 343 8 346 305 0 0 0 0 -5.9 0 -5.6 -6 11/03/2004 17:00:00 10.9 1.2 13.3 8.4 11.2 1.3 14.1 8 0.4 0 0.4 0.4 343 6 336 305 0 0 0 0 -5.9 0 -5.8 -6.2 11/03/2004 17:10:00 11.2 1 13.3 8.4 11.5 1.1 13.7 8.4 0.4 0 0.4 0.4 346 7 342 305 0 0 0 0 -5.8 0 -5.6 -6 11/03/2004 17:20:00 11.6 1.1 14.5 8.8 11.9 1.1 14.9 9.1 0.4 0 0.4 0.4 341 6 344 305 0 0 0 0 -5.9 0 -5.6 -6 11/03/2004 17:30:00 11.7 1 14.5 8.8 12 1.1 14.9 9.1 0.4 0 0.4 0.4 348 6 355 305 0 0 0 0 -5.9 0.1 -5.8 -6 11/03/2004 17:40:00 11.5 1.1 14.5 8.4 11.9 1.1 15.3 8.8 0.4 0 0.4 0.4 341 5 350 305 0 0 0 0 -5.9 0 -5.8 -6 11/03/2004 17:50:00 11.7 1 14.5 8.8 12 1.1 14.5 9.1 0.4 0 0.4 0.4 346 6 352 305 0 0 0 0 -5.8 0.1 -5.6 -6 11/03/2004 18:00:00 11.1 1.1 13.3 8.4 11.4 1.2 14.1 8.4 0.4 0 0.4 0.4 344 6 354 305 0 0 0 0 -5.8 0 -5.3 -6 11/03/2004 18:10:00 11.2 0.8 13 9.1 11.5 0.8 13.3 9.5 0.4 0 0.4 0.4 343 6 342 305 0 0 0 0 -5.8 0.1 -5.3 -6 11/03/2004 18:20:00 11 1.1 14.1 8.8 11.5 1.1 14.5 9.1 0.4 0 0.4 0.4 342 5 338 305 0 0 0 0 -5.9 0.1 -5.3 -6 11/03/2004 18:30:00 10.8 1.3 13.7 8 11.2 1.5 14.1 8.4 0.4 0 0.4 0.4 345 6 346 305 0 0 0 0 -5.9 0 -5.8 -6 11/03/2004 18:40:00 11.2 1.2 14.1 8 11.6 1.2 14.5 8.4 0.4 0 0.4 0.4 345 5 345 305 0 0 0 0 -5.9 0 -5.6 -6 11/03/2004 18:50:00 11.1 1.1 13.7 8.4 11.3 1.2 14.5 8.8 0.4 0 0.4 0.4 348 7 351 305 0 0 0 0 -5.8 0 -5.3 -6 11/03/2004 19:00:00 11.2 1.2 13.7 8 11.5 1.2 14.1 8.8 0.4 0 0.4 0.4 348 5 344 305 0 0 0 0 -5.8 0.1 -5.6 -6 11/03/2004 19:10:00 11.2 1.1 13.7 8.8 11.5 1.1 14.1 9.1 0.4 0 0.4 0.4 344 7 358 305 0 0 0 0 -5.9 0.1 -5.3 -6 11/03/2004 19:20:00 11 1 13.3 8.4 11.4 1 13.3 8.8 0.4 0 0.4 0.4 350 7 349 305 0 0 0 0 -5.9 0 -5.6 -6 11/03/2004 19:30:00 11.4 1.1 13.7 8.8 11.8 1.1 14.1 8.4 0.4 0 0.4 0.4 345 5 343 305 0 0 0 0 -5.9 0.1 -5.3 -6.2 11/03/2004 19:40:00 11 1.1 13.7 8 11.3 1.1 14.5 8.4 0.4 0 0.4 0.4 344 6 351 305 0 0 0 0 -6.1 0 -6 -6.2 11/03/2004 19:50:00 11.2 0.9 13.7 8.8 11.5 1 14.1 9.1 0.4 0 0.4 0.4 348 6 332 305 0 0 0 0 -6 0 -5.6 -6 11/03/2004 20:00:00 11 0.9 13.3 8 11.4 1 14.1 8.4 0.4 0 0.4 0.4 352 6 352 305 0 0 0 0 -6 0 -5.8 -6 11/03/2004 20:10:00 11.4 1 14.1 9.1 11.7 1 14.5 9.1 0.4 0 0.4 0.4 349 6 352 305 0 0 0 0 -5.9 0 -5.8 -6.2 11/03/2004 20:20:00 11.2 1.1 13.7 7.6 11.5 1.2 14.5 8.4 0.4 0 0.4 0.4 353 5 359 305 0 0 0 0 -6 0 -5.8 -6 11/03/2004 20:30:00 11.3 0.8 13.3 9.1 11.6 0.9 13.7 8.8 0.4 0 0.4 0.4 356 4 6 305 0 0 0 0 -5.9 0.1 -5.6 -6 11/03/2004 20:40:00 10.9 1.2 13.7 8.4 11.3 1.2 14.1 8 0.4 0 0.4 0.4 356 6 351 305 0 0 0 0 -6 0 -5.8 -6.2 11/03/2004 20:50:00 10.7 0.8 13.7 8.8 11.1 0.9 13.7 8.8 0.4 0 0.4 0.4 353 7 344 305 0 0 0 0 -5.8 0.1 -5.6 -6 11/03/2004 21:00:00 11.3 1 14.5 8.4 11.7 1.1 14.9 8.4 0.4 0 0.4 0.4 351 6 353 305 0 0 0 0 -5.9 0.1 -5.3 -6 11/03/2004 21:10:00 10.7 1 13.3 8 11 1 13.3 8 0.4 0 0.4 0.4 351 6 342 305 0 0 0 0 -5.9 0.1 -5.6 -6.2 11/03/2004 21:20:00 10.1 1 12.6 8 10.5 1.1 13.3 8.4 0.4 0 0.4 0.4 349 5 346 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 21:30:00 10.3 0.8 13 8.4 10.6 0.9 13 8.8 0.4 0 0.4 0.4 353 7 354 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 21:40:00 10.4 0.9 13 8.4 10.8 0.9 13.3 8.4 0.4 0 0.4 0.4 356 5 354 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 21:50:00 10 1 12.6 8 10.3 1.1 13 7.6 0.4 0 0.4 0.4 356 5 4 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 22:00:00 10.1 0.8 11.8 7.6 10.4 0.8 12.6 8 0.4 0 0.4 0.4 351 6 355 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 22:10:00 9.7 1 12.2 6.8 10 1.1 12.6 7.6 0.4 0 0.4 0.4 349 7 350 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 22:20:00 9.8 1 12.2 7.2 10.2 1.1 13 7.2 0.4 0 0.4 0.4 350 7 354 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 22:30:00 9.6 0.8 12.2 7.6 9.9 0.8 12.2 7.6 0.4 0 0.4 0.4 350 7 348 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/03/2004 22:40:00 10.1 1 12.6 7.6 10.6 1 13 8.4 0.4 0 0.4 0.4 349 6 351 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 22:50:00 9.9 1.3 12.6 7.2 10.3 1.3 13.3 7.2 0.4 0 0.4 0.4 350 7 345 305 0 0 0 0 -6 0 -5.6 -6.2 11/03/2004 23:00:00 9.4 1.2 12.6 6.8 9.7 1.2 12.6 6.8 0.4 0 0.4 0.4 354 6 350 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 23:10:00 9.1 1 11.5 6.5 9.4 1 11.8 6.8 0.4 0 0.4 0.4 353 5 0 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 23:20:00 9.1 1.2 11.8 5.7 9.4 1.3 12.2 5.7 0.4 0 0.4 0.4 352 6 349 305 0 0 0 0 -6.1 0 -5.6 -6.4 11/03/2004 23:30:00 8.9 1 11.5 6.1 9.2 1 11.8 6.5 0.4 0 0.4 0.4 347 6 334 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/03/2004 23:40:00 9.5 1 11.8 6.8 9.8 1 12.2 7.2 0.4 0 0.4 0.4 346 6 346 305 0 0 0 0 -6.2 0 -5.6 -6.2 11/03/2004 23:50:00 9 1 11.8 6.8 9.4 1.1 11.8 7.2 0.4 0 0.4 0.4 344 6 353 305 0 0 0 0 -6.2 0 -5.8 -6.4 11/04/2004 00:00:00 8.9 1 11.1 5.7 9.2 1.1 11.1 5.3 0.4 0 0.4 0.4 345 7 349 305 0 0 0 0 -6.2 0 -5.8 -6.4 11/04/2004 00:10:00 9.4 0.7 11.1 7.6 9.7 0.7 11.5 8 0.4 0 0.4 0.4 341 8 342 305 0 0 0 0 -6.2 0.1 -6 -6.7 11/04/2004 00:20:00 8.7 0.9 11.5 6.8 9.1 1 12.2 6.8 0.4 0 0.4 0.4 343 6 339 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/04/2004 00:30:00 9.1 0.8 11.1 6.8 9.4 0.9 11.5 6.8 0.4 0 0.4 0.4 342 7 337 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/04/2004 00:40:00 8.9 0.9 11.1 6.8 9.2 0.9 11.5 7.2 0.4 0 0.4 0.4 347 7 351 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/04/2004 00:50:00 8.7 1 10.7 6.8 9 1 11.5 6.5 0.4 0 0.4 0.4 350 8 340 305 0 0 0 0 -6.3 0 -6.2 -6.7 11/04/2004 01:00:00 9 0.8 11.1 6.5 9.3 0.9 11.5 6.5 0.4 0 0.4 0.4 355 6 352 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/04/2004 01:10:00 8.9 1 11.8 6.8 9.2 1 11.8 7.2 0.4 0 0.4 0.4 355 6 352 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/04/2004 01:20:00 9 0.7 10.7 6.8 9.3 0.8 11.1 6.8 0.4 0 0.4 0.4 353 6 6 305 0 0 0 0 -6.5 0 -6.2 -6.9 11/04/2004 01:30:00 8.6 0.8 10.7 6.5 9 0.8 11.5 6.8 0.4 0 0.4 0.4 352 5 343 305 0 0 0 0 -6.5 0 -6.4 -6.9 11/04/2004 01:40:00 8.5 0.8 11.1 6.5 8.8 0.9 11.1 6.8 0.4 0 0.4 0.4 2 7 357 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/04/2004 01:50:00 8.7 1 11.1 6.1 9 1 11.5 6.8 0.4 0 0.4 0.4 1 7 8 305 0 0 0 0 -6.6 0 -6.4 -6.9 11/04/2004 02:00:00 8.7 0.8 11.1 6.8 8.9 0.8 11.1 6.8 0.4 0 0.4 0.4 5 6 358 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/04/2004 02:10:00 8.2 1 10.3 6.1 8.3 1 10.7 6.1 0.4 0 0.4 0.4 9 6 12 305 0 0 0 0 -6.6 0 -6.4 -6.7 11/04/2004 02:20:00 8.2 0.9 11.1 6.5 8.5 0.9 11.8 6.8 0.4 0 0.4 0.4 3 7 9 305 0 0 0 0 -6.6 0 -6.7 -6.7 11/04/2004 02:30:00 7.8 0.8 9.5 5.3 8.1 0.8 10.3 6.1 0.4 0 0.4 0.4 7 6 8 305 0 0 0 0 -6.6 0 -6.4 -6.7 11/04/2004 02:40:00 8.4 0.7 10.7 6.1 8.7 0.7 11.1 6.5 0.4 0 0.4 0.4 7 5 11 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/04/2004 02:50:00 8.4 0.8 10.3 6.5 8.7 0.7 10.3 7.2 0.4 0 0.4 0.4 5 5 4 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/04/2004 03:00:00 7.4 0.8 9.1 5.7 7.6 0.9 9.9 5.7 0.4 0 0.4 0.4 6 7 0 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/04/2004 03:10:00 8 0.9 9.9 6.1 8.2 1 10.7 5.7 0.4 0 0.4 0.4 5 7 1 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/04/2004 03:20:00 7.4 1 9.9 5.7 7.7 1 10.3 5.3 0.4 0 0.4 0.4 8 8 3 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/04/2004 03:30:00 7.3 0.5 8.8 5.7 7.6 0.6 9.1 5.7 0.4 0 0.4 0.4 3 7 351 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/04/2004 03:40:00 6.7 1.2 9.5 3.4 6.9 1.2 10.3 3.4 0.4 0 0.4 0.4 6 8 5 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/04/2004 03:50:00 8.4 0.7 10.3 6.8 8.7 0.8 11.1 6.8 0.4 0 0.4 0.4 7 7 4 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/04/2004 04:00:00 8.6 0.6 10.3 6.5 9 0.6 10.7 6.8 0.4 0 0.4 0.4 3 8 358 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/04/2004 04:10:00 8.3 0.7 9.9 6.5 8.6 0.8 10.3 6.8 0.4 0 0.4 0.4 5 6 5 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/04/2004 04:20:00 8.4 0.6 9.9 6.8 8.8 0.7 10.7 7.2 0.4 0 0.4 0.4 2 6 357 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/04/2004 04:30:00 7.7 0.9 9.5 5.7 7.9 1 10.3 5.3 0.4 0 0.7 0.4 6 8 3 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/04/2004 04:40:00 8.1 0.8 10.3 6.5 8.3 0.8 10.7 6.1 0.4 0 0.4 0.4 5 7 2 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/04/2004 04:50:00 8.6 0.9 11.1 6.8 8.9 0.9 11.5 6.5 0.4 0 0.4 0.4 3 7 3 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/04/2004 05:00:00 8.6 1.1 11.8 6.1 8.9 1.1 12.2 5.7 0.4 0 0.4 0.4 2 8 7 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/04/2004 05:10:00 7.6 0.8 9.5 5.3 7.8 0.8 10.7 5.7 0.4 0 0.4 0.4 7 6 7 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/04/2004 05:20:00 8 0.8 9.9 6.1 8.2 0.9 10.3 6.1 0.4 0 0.4 0.4 6 7 11 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/04/2004 05:30:00 7.9 0.7 10.3 6.5 8.2 0.7 10.7 6.5 0.4 0 0.4 0.4 6 6 2 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/04/2004 05:40:00 8.1 1 10.7 6.1 8.3 1 11.1 6.1 0.4 0 0.4 0.4 8 7 0 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/04/2004 05:50:00 7.7 0.7 9.5 5.7 7.9 0.8 10.7 6.5 0.4 0 0.4 0.4 9 7 9 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/04/2004 06:00:00 7.8 0.9 9.9 5.7 8 1 10.3 6.1 0.4 0 0.4 0.4 8 7 14 305 0 0 0 0 -6.7 0 -6.4 -6.9 11/04/2004 06:10:00 8.5 0.8 10.3 6.5 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 8 6 13 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/04/2004 06:20:00 7.6 0.7 9.5 5.7 7.9 0.8 9.9 5.7 0.4 0 0.4 0.4 1 6 355 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/04/2004 06:30:00 7.6 0.9 9.5 5.7 7.8 0.9 9.5 5.7 0.4 0 0.4 0.4 5 7 3 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/04/2004 06:40:00 7.5 0.7 9.9 6.1 7.8 0.7 9.9 6.5 0.4 0 0.4 0.4 2 8 348 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/04/2004 06:50:00 7.9 0.9 9.9 6.1 8.1 0.9 10.3 6.1 0.4 0 0.4 0.4 2 8 6 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/04/2004 07:00:00 7.1 0.9 9.1 4.9 7.3 0.9 9.1 5.3 0.4 0 0.4 0.4 4 12 353 305 0 0 0 0 -6.8 0 -6.7 -7.1 11/04/2004 07:10:00 7.1 0.8 9.1 5.7 7.4 0.8 9.5 5.7 0.4 0 0.4 0.4 3 7 11 305 0 0 0 0 -6.8 0 -6.7 -7.1 11/04/2004 07:20:00 7 1 9.5 4.2 7.3 1.1 9.9 4.6 0.4 0 0.4 0.4 1 6 359 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/04/2004 07:30:00 6.6 0.8 8.4 4.2 6.9 0.8 8.8 4.6 0.4 0 0.4 0.4 5 6 7 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/04/2004 07:40:00 6.7 1.1 9.5 4.6 7 1.1 9.9 4.6 0.4 0 0.4 0.4 1 7 1 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/04/2004 07:50:00 6.7 0.8 8.8 4.9 6.9 0.8 9.1 4.9 0.4 0 0.4 0.4 8 9 8 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/04/2004 08:00:00 7.2 0.8 9.5 5.3 7.5 0.9 9.9 5.7 0.4 0 0.4 0.4 3 6 356 305 0 0 0 0 -6.6 0 -6.2 -6.9 11/04/2004 08:10:00 7.2 1 10.3 4.9 7.4 1 11.5 4.9 0.4 0 0.4 0.4 2 7 5 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/04/2004 08:20:00 6.6 1 9.5 4.6 6.8 1.1 9.9 4.6 0.4 0 0.4 0.4 16 7 15 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/04/2004 08:30:00 7.5 0.8 10.3 5.7 7.7 0.8 10.7 5.7 0.4 0 0.4 0.4 9 8 3 305 0 0 0 0 -6.6 0 -6.7 -6.9 11/04/2004 08:40:00 7 0.7 10.3 4.9 7.2 0.8 10.7 5.7 0.4 0 0.4 0.4 2 8 358 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/04/2004 08:50:00 5.7 0.8 7.2 3.8 6 0.9 8 4.2 0.4 0 0.4 0.4 355 7 8 305 0 0 0 0 -6.8 0 -6.2 -6.9 11/04/2004 09:00:00 5.6 1 8 3.4 5.8 1 8.4 3.8 0.4 0 0.4 0.4 10 11 19 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/04/2004 09:10:00 7 0.7 8.8 5.3 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 1 8 6 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/04/2004 09:20:00 6.6 0.8 8.4 4.6 6.8 0.8 8.4 4.9 0.4 0 0.4 0.4 5 6 5 305 0 0 0 0 -6.9 0 -6.7 -6.9 11/04/2004 09:30:00 6.1 0.6 8 4.6 6.4 0.6 8 4.6 0.4 0 0.4 0.4 13 6 10 305 0 0 0 0 -6.9 0 -6.9 -7.1 11/04/2004 09:40:00 7.3 1 9.1 4.9 7.5 1 10.3 4.6 0.4 0 0.4 0.4 6 8 5 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/04/2004 09:50:00 7.1 0.7 9.1 5.3 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 12 8 1 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/04/2004 10:00:00 7 0.8 8.8 4.9 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 5 7 7 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/04/2004 10:10:00 6.3 0.9 8 4.2 6.6 1 8.4 4.6 0.4 0 0.4 0.4 7 7 9 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/04/2004 10:20:00 6.1 0.7 8 4.2 6.3 0.7 8 4.2 0.4 0 0.4 0.4 3 8 2 305 0 0 0 0 -6.9 0 -6.9 -7.1 11/04/2004 10:30:00 6.8 0.7 8.8 4.9 7 0.8 9.1 4.9 0.4 0 0.4 0.4 2 9 1 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/04/2004 10:40:00 6.5 0.8 8.4 3.8 6.8 0.8 9.1 4.6 0.4 0 0.4 0.4 357 8 354 305 0 0 0 0 -6.9 0 -6.7 -6.9 11/04/2004 10:50:00 5.9 0.9 8.8 3.4 6.2 0.8 8.8 4.2 0.4 0 0.4 0.4 359 11 357 305 0 0 0 0 -7 0 -6.7 -7.1 11/04/2004 11:00:00 6.7 0.7 9.1 4.9 6.9 0.7 9.1 4.9 0.4 0 0.4 0.4 3 9 5 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/04/2004 11:10:00 5.6 0.8 8 3.8 6 0.8 8 4.2 0.4 0 0.4 0.4 357 6 355 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 11:20:00 6 1 8.4 3.8 6.3 1 8.4 4.2 0.4 0 0.4 0.4 358 7 358 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 11:30:00 6.4 0.8 8.8 4.6 6.6 0.8 9.1 4.9 0.4 0 0.4 0.4 2 6 19 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 11:40:00 6.6 0.6 8 4.6 6.9 0.7 8.4 4.9 0.4 0 0.4 0.4 1 8 0 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 11:50:00 6.7 0.7 8.4 4.9 6.9 0.7 8.8 5.3 0.4 0 0.4 0.4 14 7 19 305 0 0 0 0 -7.1 0 -6.9 -7.1 11/04/2004 12:00:00 6.3 0.6 7.6 4.6 6.5 0.6 8 4.6 0.4 0 0.4 0.4 10 7 351 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 12:10:00 6.1 1 8.4 3.8 6.4 1 9.1 4.2 0.4 0 0.4 0.4 11 7 19 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 12:20:00 7.1 0.7 8.8 5.3 7.3 0.7 8.8 5.3 0.4 0 0.4 0.4 19 6 12 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 12:30:00 7.5 0.7 8.8 5.3 7.7 0.7 9.5 5.3 0.4 0 0.4 0.4 25 7 27 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 12:40:00 6.9 0.7 8.8 4.9 7 0.7 8.8 4.9 0.4 0 0.4 0.4 29 6 27 305 0 0 0 0 -6.8 0 -6.7 -7.1 11/04/2004 12:50:00 6.4 0.7 8.4 4.6 6.5 0.7 10.3 4.9 0.4 0 0.4 0.4 24 9 12 305 0 0 0 0 -6.8 0 -6.7 -7.1 11/04/2004 13:00:00 5.8 0.8 8.4 3.8 5.9 0.8 8.4 4.2 0.4 0 0.4 0.4 24 9 12 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/04/2004 13:10:00 6.1 0.6 7.6 4.2 6.2 0.7 8.8 4.6 0.4 0 0.4 0.4 24 6 14 305 0 0 0 0 -7 0.1 -6.7 -7.1 11/04/2004 13:20:00 5.6 0.6 7.2 4.2 5.7 0.6 6.8 3.8 0.4 0 0.4 0.4 28 9 32 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 13:30:00 5.1 0.9 8 3.4 5.3 0.9 7.6 3.8 0.4 0 0.4 0.4 31 9 48 305 0 0 0 0 -7.1 0 -6.9 -7.1 11/04/2004 13:40:00 5.7 0.7 7.6 3.8 5.8 0.7 7.6 4.2 0.4 0 0.4 0.4 32 9 46 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/04/2004 13:50:00 6 0.6 7.6 4.6 6.2 0.6 8 4.6 0.4 0 0.4 0.4 22 6 25 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/04/2004 14:00:00 5.9 0.7 7.2 4.2 6 0.7 7.6 4.2 0.4 0 0.4 0.4 27 7 25 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 14:10:00 5.8 0.7 8.4 4.2 5.9 0.7 8.8 4.6 0.4 0 0.4 0.4 36 7 41 305 0 0 0 0 -7.1 0 -6.9 -7.1 11/04/2004 14:20:00 5 0.6 6.5 3 5.2 0.7 6.8 3.4 0.4 0 0.4 0.4 38 9 40 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 14:30:00 5.1 0.7 6.8 3.4 5.4 0.6 6.8 3.8 0.4 0 0.4 0.4 25 12 30 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 14:40:00 4.4 0.7 6.8 3 4.5 0.7 6.5 3 0.4 0 0.4 0.4 28 9 28 305 0 0 0 0 -7.1 0 -6.9 -7.1 11/04/2004 14:50:00 4.7 0.6 6.8 3.4 4.9 0.6 6.8 3 0.4 0 0.4 0.4 26 12 19 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 15:00:00 4 0.8 6.1 2.3 4.2 0.8 6.5 2.3 0.4 0 0.4 0.4 24 11 5 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 15:10:00 4.4 0.7 6.1 3 4.6 0.6 6.5 3 0.4 0 0.4 0.4 36 9 40 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 15:20:00 4.6 0.7 6.1 3 4.7 0.7 6.1 3 0.4 0 0.4 0.4 42 7 36 305 0 0 0 0 -7.1 0 -6.9 -7.1 11/04/2004 15:30:00 4.3 0.5 5.7 3 4.5 0.5 6.1 3.4 0.4 0 0.4 0.4 15 10 9 305 0 0 0 0 -7.1 0 -6.9 -7.3 11/04/2004 15:40:00 4.2 1 6.5 1.9 4.4 1 6.5 2.3 0.4 0 0.4 0.4 19 12 22 305 0 0 0 0 -7.1 0 -6.9 -7.1 11/04/2004 15:50:00 4.2 0.7 6.1 2.3 4.5 0.8 6.1 2.6 0.4 0 0.4 0.4 29 8 25 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 16:00:00 4.3 0.6 6.1 2.6 4.4 0.6 5.7 3 0.4 0 0.4 0.4 24 7 22 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 16:10:00 3.9 0.6 5.3 2.6 4.2 0.6 5.7 2.6 0.4 0 0.4 0.4 37 10 29 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 16:20:00 3.2 0.5 4.6 2.3 3.5 0.6 4.9 1.9 0.4 0 0.4 0.4 26 12 36 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 16:30:00 2.5 0.6 3.8 1.1 2.8 0.7 4.2 0.7 0.4 0 0.4 0.4 36 10 33 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 16:40:00 1.7 1 3.8 0.4 2.1 0.7 3.8 0.4 0.4 0 0.4 0.4 26 17 34 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 16:50:00 2 0.8 3.4 0.4 2.3 0.7 3.4 0.7 0.4 0 0.4 0.4 50 12 61 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 17:00:00 1.2 0.6 3 0.4 1.7 0.5 3.4 0.4 0.4 0 0.4 0.4 350 36 29 305 0 0 0 0 -7 0 -6.9 -7.1 11/04/2004 17:10:00 0.8 0.6 2.3 0.4 1.1 0.6 2.6 0.4 0.4 0 0.4 0.4 328 16 313 305 0 0 0 0 -7.1 0 -6.7 -7.3 11/04/2004 17:20:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 301 18 296 305 0 0 0 0 -7.1 0 -7.1 -7.3 11/04/2004 17:30:00 0.4 0.1 0.7 0.4 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 258 51 193 305 0 0 0 0 -7.2 0 -7.1 -7.3 11/04/2004 17:40:00 0.6 0.2 1.1 0.4 1.3 0.2 1.9 0.7 0.4 0 0.4 0.4 166 7 165 305 0 0 0 0 -7.4 0.1 -7.3 -7.7 11/04/2004 17:50:00 0.4 0.1 1.1 0.4 1.1 0.3 1.9 0.4 0.4 0 0.4 0.4 166 9 170 305 0 0 0 0 -7.7 0 -7.3 -7.9 11/04/2004 18:00:00 0.4 0 0.7 0.4 0.8 0.2 1.5 0.4 0.4 0 0.4 0.4 171 0 170 305 0 0 0 0 -8.3 0.2 -7.7 -8.6 11/04/2004 18:10:00 0.5 0.3 1.5 0.4 1.1 0.3 2.3 0.4 0.4 0 0.4 0.4 162 11 146 305 0 0 0 0 -8.7 0 -8.4 -8.8 11/04/2004 18:20:00 1.2 0.4 2.3 0.4 1.7 0.3 2.6 1.1 0.4 0 0.4 0.4 128 9 125 305 0 0 0 0 -8.7 0 -8.4 -8.8 11/04/2004 18:30:00 0.7 0.4 1.9 0.4 1.2 0.5 2.3 0.4 0.4 0 0.4 0.4 130 7 131 305 0 0 0 0 -8.5 0 -8.4 -8.6 11/04/2004 18:40:00 0.5 0.4 1.9 0.4 1.2 0.4 2.3 0.4 0.4 0 0.4 0.4 114 12 103 305 0 0 0 0 -8.4 0 -8.2 -8.6 11/04/2004 18:50:00 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 99 12 90 305 0 0 0 0 -8.2 0 -7.9 -8.4 11/04/2004 19:00:00 0.6 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.4 0 0.4 0.4 187 47 254 305 0 0 0 0 -7.9 0 -7.7 -7.9 11/04/2004 19:10:00 2.5 0.7 4.6 1.1 2.4 0.9 4.2 1.1 0.4 0 0.4 0.4 229 27 227 305 0 0 0 0 -7.7 0 -7.5 -7.9 11/04/2004 19:20:00 2.7 0.5 3.8 1.5 3.4 0.3 3.8 2.6 0.4 0 0.4 0.4 184 5 190 305 0 0 0 0 -7.8 0 -7.7 -7.9 11/04/2004 19:30:00 2.1 0.4 3 1.1 3.4 0.3 3.8 2.3 0.4 0 0.4 0.4 176 3 179 305 0 0 0 0 -8 0 -7.7 -8.2 11/04/2004 19:40:00 1 0.6 2.3 0.4 1.6 0.6 2.6 0.4 0.4 0 0.4 0.4 182 13 183 305 0 0 0 0 -7.9 0 -7.9 -8.2 11/04/2004 19:50:00 0.9 0.4 1.9 0.4 1.6 0.3 2.3 0.7 0.4 0 0.4 0.4 160 14 184 305 0 0 0 0 -7.9 0 -7.7 -7.9 11/04/2004 20:00:00 1 0.4 1.9 0.4 1.5 0.2 1.9 1.1 0.4 0 0.4 0.4 133 12 125 305 0 0 0 0 -8.1 0 -7.9 -8.2 11/04/2004 20:10:00 1.7 0.4 2.3 0.4 2 0.2 2.6 1.5 0.4 0 0.4 0.4 114 4 117 305 0 0 0 0 -8.5 0.2 -8.2 -8.8 11/04/2004 20:20:00 1.4 0.5 2.6 0.4 1.9 0.4 2.6 1.1 0.4 0 0.4 0.4 114 5 119 305 0 0 0 0 -8.6 0 -8.4 -8.8 11/04/2004 20:30:00 0.9 0.7 2.3 0.4 1.5 0.5 2.6 0.4 0.4 0 0.4 0.4 119 13 132 305 0 0 0 0 -8.2 0 -7.9 -8.4 11/04/2004 20:40:00 1.2 0.8 2.6 0.4 1.7 0.5 2.6 0.4 0.4 0 0.4 0.4 118 13 123 305 0 0 0 0 -7.9 0 -7.7 -7.9 11/04/2004 20:50:00 0.5 0.4 1.9 0.4 1 0.6 2.3 0.4 0.4 0 0.4 0.4 127 5 113 305 0 0 0 0 -7.8 0 -7.7 -7.9 11/04/2004 21:00:00 1 0.5 1.9 0.4 1.7 0.4 2.6 0.7 0.4 0 0.4 0.4 156 15 155 305 0 0 0 0 -7.8 0 -7.7 -7.9 11/04/2004 21:10:00 1 0.4 1.9 0.4 1.6 0.2 2.3 1.1 0.4 0 0.4 0.4 158 5 158 305 0 0 0 0 -8 0 -7.7 -8.2 11/04/2004 21:20:00 1 0.8 2.6 0.4 1.5 0.7 2.6 0.4 0.4 0 0.4 0.4 173 22 192 305 0 0 0 0 -8.4 0.1 -8.2 -8.8 11/04/2004 21:30:00 0.6 0.5 1.9 0.4 1.4 0.5 2.3 0.4 0.4 0 0.4 0.4 191 17 194 305 0 0 0 0 -8.6 0 -8.4 -8.8 11/04/2004 21:40:00 0.4 0.1 0.7 0.4 1.3 0.2 1.9 0.7 0.4 0 0.4 0.4 196 5 185 305 0 0 0 0 -8.9 0.1 -8.8 -9.2 11/04/2004 21:50:00 0.5 0.2 1.1 0.4 1.3 0.4 1.9 0.4 0.4 0 0.4 0.4 172 4 183 305 0 0 0 0 -8.9 0.1 -8.6 -9.2 11/04/2004 22:00:00 0.5 0.3 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0 0.4 0.4 187 6 179 305 0 0 0 0 -9 0.2 -8.8 -9.4 11/04/2004 22:10:00 0.9 0.6 2.3 0.4 1.5 0.5 2.6 0.4 0.4 0 0.4 0.4 197 28 209 305 0 0 0 0 -9.4 0.3 -8.8 -9.8 11/04/2004 22:20:00 0.8 0.6 2.3 0.4 1.6 0.4 3 0.7 0.4 0 0.4 0.4 197 20 193 305 0 0 0 0 -9 0.1 -8.8 -9.2 11/04/2004 22:30:00 1.4 0.4 2.3 0.4 1.9 0.3 3 1.1 0.4 0 0.4 0.4 204 5 205 305 0 0 0 0 -8.8 0 -8.8 -9.2 11/04/2004 22:40:00 1.3 0.6 2.6 0.4 1.8 0.5 2.6 0.4 0.4 0 0.4 0.4 193 9 203 305 0 0 0 0 -8.8 0.3 -8.2 -9.2 11/04/2004 22:50:00 1.1 0.6 2.3 0.4 1.4 0.6 2.3 0.4 0.4 0 0.4 0.4 195 12 194 305 0 0 0 0 -8.1 0.1 -7.7 -8.2 11/04/2004 23:00:00 2 0.5 3 0.7 2.5 0.4 3.8 1.5 0.4 0 0.4 0.4 190 11 197 305 0 0 0 0 -7.6 0 -7.3 -7.9 11/04/2004 23:10:00 0.9 0.5 2.3 0.4 1.2 0.6 2.6 0.4 0.4 0 0.4 0.4 211 23 190 305 0 0 0 0 -7.4 0 -7.1 -7.7 11/04/2004 23:20:00 1.7 0.6 3 0.4 1.7 0.5 3 0.4 0.4 0 0.4 0.4 246 27 210 305 0 0 0 0 -7.5 0.1 -7.1 -7.7 11/04/2004 23:30:00 3.6 1.1 6.1 1.5 3.3 1.1 5.7 0.7 0.4 0 0.4 0.4 290 22 300 305 0 0 0 0 -7.5 0.2 -6.9 -7.7 11/04/2004 23:40:00 4.6 0.7 6.1 3 4.2 0.6 5.3 2.3 0.4 0 0.4 0.4 292 11 283 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/04/2004 23:50:00 4.6 1.2 7.2 3 4.3 1.1 7.2 3 0.4 0 0.4 0.4 299 13 300 305 0 0 0 0 -6.9 0.1 -6.7 -7.1 11/05/2004 00:00:00 4.7 0.9 6.5 3 4.6 0.9 6.1 3 0.4 0 0.4 0.4 299 5 292 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/05/2004 00:10:00 3.8 0.6 5.3 2.6 3.7 0.6 5.3 2.3 0.4 0 0.4 0.4 294 9 300 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/05/2004 00:20:00 3.5 0.7 6.1 2.3 3.4 0.6 5.7 2.6 0.4 0 0.4 0.4 302 7 303 305 0 0 0 0 -6.9 0 -6.9 -7.1 11/05/2004 00:30:00 4.6 0.7 6.1 2.3 4.4 0.7 5.7 2.6 0.4 0 0.4 0.4 293 8 300 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/05/2004 00:40:00 3.6 0.8 5.7 2.3 3 0.8 4.9 1.5 0.4 0 0.4 0.4 274 11 279 305 0 0 0 0 -6.8 0 -6.4 -6.9 11/05/2004 00:50:00 4.3 0.6 6.1 3 4.1 0.5 5.3 3 0.4 0 0.4 0.4 293 5 291 305 0 0 0 0 -6.9 0.1 -6.7 -7.1 11/05/2004 01:00:00 3.3 0.6 4.9 1.9 3.1 0.7 4.9 1.5 0.4 0 0.4 0.4 287 8 288 305 0 0 0 0 -6.8 0 -6.7 -7.1 11/05/2004 01:10:00 3.3 1 5.7 1.5 3.3 1.1 5.3 0.7 0.4 0 0.4 0.4 295 13 297 305 0 0 0 0 -6.9 0.1 -6.7 -7.1 11/05/2004 01:20:00 3.8 0.8 5.7 2.3 3.6 0.6 5.3 2.3 0.4 0 0.4 0.4 291 10 286 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/05/2004 01:30:00 3.8 0.7 5.7 2.6 3.2 0.7 4.9 1.9 0.4 0 0.4 0.4 278 9 276 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/05/2004 01:40:00 3.1 0.6 4.6 1.9 2.6 0.6 3.8 1.5 0.4 0 0.4 0.4 277 18 268 305 0 0 0 0 -6.6 0 -6.4 -6.9 11/05/2004 01:50:00 3.1 0.5 4.2 1.9 2.7 0.5 3.8 1.5 0.4 0 0.4 0.4 280 9 276 305 0 0 0 0 -6.7 0 -6.4 -6.9 11/05/2004 02:00:00 3.5 0.6 6.1 1.5 2.9 0.6 4.9 1.5 0.4 0 0.4 0.4 268 14 256 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/05/2004 02:10:00 3.3 0.6 4.6 2.3 3 0.6 4.2 1.5 0.4 0 0.4 0.4 279 9 281 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/05/2004 02:20:00 2.8 0.7 4.6 1.5 2.3 0.6 4.2 1.1 0.4 0 0.4 0.4 267 12 276 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/05/2004 02:30:00 2.4 0.7 4.6 0.7 2.2 0.7 4.2 1.1 0.4 0 0.4 0.4 278 9 284 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 02:40:00 2.8 1 5.3 0.4 2.7 0.8 5.3 0.7 0.4 0 0.4 0.4 300 13 288 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 02:50:00 2.4 0.7 4.2 0.4 2.7 0.6 3.8 0.7 0.4 0 0.4 0.4 351 18 4 305 0 0 0 0 -6.2 0 -6 -6.4 11/05/2004 03:00:00 2.9 0.5 4.2 1.5 3.1 0.5 4.6 1.9 0.4 0 0.4 0.4 357 7 1 305 0 0 0 0 -6.2 0 -6 -6.4 11/05/2004 03:10:00 2.2 0.4 3 1.5 2.5 0.4 3.8 1.5 0.4 0 0.4 0.4 11 10 0 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 03:20:00 1.9 0.5 3 0.4 2.1 0.5 3.4 1.1 0.4 0 0.4 0.4 24 9 29 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/05/2004 03:30:00 1.8 0.4 2.6 0.7 2.1 0.4 3 1.1 0.4 0 0.4 0.4 12 9 6 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/05/2004 03:40:00 0.9 0.6 2.3 0.4 1.4 0.5 2.6 0.4 0.4 0 0.4 0.4 13 10 35 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 03:50:00 2.6 1.1 4.6 0.4 2.9 1.1 4.9 1.1 0.4 0 0.4 0.4 359 7 359 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/05/2004 04:00:00 3.4 0.5 4.9 2.6 3.7 0.5 5.3 2.6 0.4 0 0.4 0.4 17 7 13 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/05/2004 04:10:00 2.9 0.4 3.8 1.9 3.1 0.4 4.6 2.3 0.4 0 0.4 0.4 16 8 10 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/05/2004 04:20:00 2.9 0.5 4.2 1.9 3.1 0.5 4.6 2.3 0.4 0 0.4 0.4 22 11 36 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/05/2004 04:30:00 3.8 0.6 5.3 2.6 4 0.6 5.3 2.6 0.4 0 0.4 0.4 30 8 38 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/05/2004 04:40:00 4.2 0.4 5.3 3.4 4.5 0.4 5.7 3.8 0.4 0 0.4 0.4 26 8 22 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/05/2004 04:50:00 3.6 0.4 4.9 2.6 3.8 0.5 4.9 2.6 0.4 0 0.4 0.4 40 8 37 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/05/2004 05:00:00 3.5 0.5 4.9 2.6 3.7 0.5 4.9 2.6 0.4 0 0.4 0.4 54 9 46 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/05/2004 05:10:00 3.5 0.5 4.6 2.3 3.7 0.5 4.9 2.3 0.4 0 0.4 0.4 47 8 57 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 05:20:00 2.8 0.5 4.2 1.5 2.9 0.5 4.2 1.9 0.4 0 0.4 0.4 44 15 61 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 05:30:00 3.6 0.6 6.1 2.3 3.7 0.6 5.7 2.6 0.4 0 0.4 0.4 57 13 61 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 05:40:00 3 0.6 4.9 1.9 3.2 0.6 4.9 1.9 0.4 0 0.4 0.4 47 17 44 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/05/2004 05:50:00 3.5 0.6 5.3 2.3 3.7 0.6 5.3 2.3 0.4 0 0.4 0.4 39 11 57 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/05/2004 06:00:00 3.8 0.5 4.6 2.3 3.9 0.5 4.9 2.6 0.4 0 0.4 0.4 45 10 34 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/05/2004 06:10:00 3.9 0.7 6.1 3 4.1 0.7 6.1 2.6 0.4 0 0.4 0.4 47 8 33 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 06:20:00 4.1 0.5 5.3 3 4.3 0.6 5.7 3 0.4 0 0.4 0.4 40 7 49 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 06:30:00 4.4 0.6 5.7 2.6 4.6 0.5 5.7 3 0.4 0 0.4 0.4 48 7 40 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 06:40:00 5.5 0.6 8.4 3.8 5.4 0.6 7.6 3.8 0.4 0 0.4 0.4 55 11 55 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 06:50:00 6.3 0.6 7.6 4.6 6.1 0.6 7.6 4.2 0.4 0 0.4 0.4 68 8 66 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 07:00:00 6.5 0.6 8 4.9 6.1 0.6 8 4.6 0.4 0 0.4 0.4 77 6 78 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 07:10:00 5.9 0.6 7.2 4.2 5.5 0.5 6.8 3.8 0.4 0 0.4 0.4 85 7 81 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 07:20:00 4.7 1.1 7.2 2.3 4.5 1 6.5 2.3 0.4 0 0.4 0.4 103 19 87 305 0 0 0 0 -6.3 0 -6.2 -6.7 11/05/2004 07:30:00 3.2 1 5.3 1.5 3.2 1 5.3 1.1 0.4 0 0.4 0.4 110 16 98 305 0 0 0 0 -6.6 0 -6.4 -6.9 11/05/2004 07:40:00 2.4 1.1 4.9 0.4 2.6 1 4.9 0.4 0.4 0 0.4 0.4 101 27 113 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/05/2004 07:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 130 30 127 305 0 0 0 0 -6.7 0 -6.4 -6.9 11/05/2004 08:00:00 1.2 0.8 2.6 0.4 1.4 0.8 3.4 0.4 0.4 0 0.4 0.4 99 27 93 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/05/2004 08:10:00 1.9 0.5 2.6 0.4 2 0.5 3 1.1 0.4 0 0.4 0.4 121 8 124 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/05/2004 08:20:00 0.8 0.5 2.3 0.4 1.5 0.4 2.6 0.4 0.4 0 0.4 0.4 160 22 134 305 0 0 0 0 -6.8 0.2 -6.7 -7.1 11/05/2004 08:30:00 0.8 0.5 1.9 0.4 1.3 0.3 2.3 0.4 0.4 0 0.4 0.4 167 12 155 305 0 0 0 0 -7.3 0.1 -7.1 -7.5 11/05/2004 08:40:00 0.6 0.3 1.5 0.4 1.1 0.4 1.9 0.4 0.4 0 0.4 0.4 176 12 156 305 0 0 0 0 -7.6 0 -7.1 -7.7 11/05/2004 08:50:00 0.8 0.5 1.9 0.4 1.4 0.4 2.3 0.4 0.4 0 0.4 0.4 218 11 234 305 0 0 0 0 -7.7 0 -7.3 -7.9 11/05/2004 09:00:00 1.7 0.3 2.3 0.7 1.9 0.3 2.6 1.1 0.4 0 0.4 0.4 208 8 218 305 0 0 0 0 -7.8 0 -7.7 -7.9 11/05/2004 09:10:00 1.4 0.4 1.9 0.4 1.5 0.3 2.3 0.4 0.4 0 0.4 0.4 196 6 201 305 0 0 0 0 -7.9 0 -7.7 -7.9 11/05/2004 09:20:00 1.4 0.7 2.6 0.4 1.7 0.6 3 0.4 0.4 0 0.4 0.4 183 26 209 305 0 0 0 0 -7.7 0 -7.7 -7.7 11/05/2004 09:30:00 3.4 0.5 4.2 1.5 3.5 0.6 4.2 1.1 0.4 0 0.4 0.4 143 4 142 305 0 0 0 0 -7.9 0.1 -7.7 -8.2 11/05/2004 09:40:00 4 0.3 4.6 3.4 4.2 0.3 4.6 3.4 0.4 0 0.4 0.4 153 7 149 305 0 0 0 0 -7.9 0 -7.7 -8.2 11/05/2004 09:50:00 3.5 0.6 4.9 2.3 4.7 0.5 5.7 3.8 0.4 0 0.4 0.4 164 2 162 305 0 0 0 0 -7.7 0 -7.3 -7.9 11/05/2004 10:00:00 4.6 0.3 5.3 3.8 5.2 0.2 5.7 4.6 0.4 0 0.4 0.4 161 1 159 305 0 0 0 0 -7.4 0 -7.3 -7.5 11/05/2004 10:10:00 4.2 0.5 5.3 3 4.2 0.5 5.7 3 0.4 0 0.4 0.4 156 3 159 305 0 0 0 0 -7.3 0 -7.3 -7.5 11/05/2004 10:20:00 3.5 0.4 4.6 1.9 3.6 0.3 4.6 2.6 0.4 0 0.4 0.4 154 5 158 305 0 0 0 0 -7.4 0 -7.3 -7.5 11/05/2004 10:30:00 3.7 0.3 4.6 3 3.7 0.3 4.6 3 0.4 0 0.4 0.4 148 3 147 305 0 0 0 0 -7.4 0 -7.3 -7.5 11/05/2004 10:40:00 3.4 0.4 4.6 2.3 3.4 0.4 4.2 2.3 0.4 0 0.4 0.4 149 5 152 305 0 0 0 0 -7.4 0 -7.1 -7.5 11/05/2004 10:50:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.5 0.4 0 0.4 0.4 144 5 138 305 0 0 0 0 -7.3 0 -7.1 -7.5 11/05/2004 11:00:00 2.8 0.4 3.8 1.9 2.8 0.4 4.2 2.3 0.4 0 0.4 0.4 146 5 141 305 0 0 0 0 -7.4 0 -7.3 -7.5 11/05/2004 11:10:00 2.5 0.4 3.4 1.1 2.6 0.4 3.4 1.9 0.4 0 0.4 0.4 132 11 140 305 0 0 0 0 -7.4 0 -7.3 -7.5 11/05/2004 11:20:00 2.6 0.7 4.6 0.7 2.5 0.7 4.9 0.7 0.4 0 0.4 0.4 115 15 131 305 0 0 0 0 -7.1 0.2 -6.7 -7.5 11/05/2004 11:30:00 3.7 1.2 6.8 1.9 3.6 1.2 7.2 1.9 0.4 0 0.4 0.4 84 21 52 305 0 0 0 0 -6.3 0.2 -6 -6.7 11/05/2004 11:40:00 6.7 1 9.5 3.8 6.4 1 8.8 3 0.4 0 0.4 0.4 72 9 72 305 0 0 0 0 -6.1 0 -5.8 -6.4 11/05/2004 11:50:00 6.3 0.6 7.6 5.3 6 0.5 7.2 4.9 0.4 0 0.4 0.4 72 6 77 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/05/2004 12:00:00 5.8 0.5 7.2 4.6 5.5 0.6 7.2 3.8 0.4 0 0.4 0.4 75 8 69 305 0 0 0 0 -6.3 0 -6.2 -6.4 11/05/2004 12:10:00 6.3 0.6 7.6 4.6 5.9 0.6 7.2 4.2 0.4 0 0.4 0.4 75 6 75 305 0 0 0 0 -6.2 0 -6 -6.4 11/05/2004 12:20:00 6.6 0.7 8.4 4.9 6.2 0.7 8 4.6 0.4 0 0.4 0.4 73 6 62 305 0 0 0 0 -6.2 0 -6 -6.2 11/05/2004 12:30:00 6.5 0.8 8.8 4.6 6.2 0.8 8 4.2 0.4 0 0.4 0.4 66 9 65 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/05/2004 12:40:00 7.5 0.9 9.5 5.7 7.3 0.9 9.5 5.3 0.4 0 0.4 0.4 65 7 54 305 0 0 0 0 -5.9 0 -5.8 -6 11/05/2004 12:50:00 8 0.8 10.3 6.5 7.9 0.8 10.3 6.1 0.4 0 0.4 0.4 58 9 77 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/05/2004 13:00:00 8.9 0.7 10.3 6.8 9 0.8 11.1 6.5 0.4 0 0.4 0.4 51 5 47 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/05/2004 13:10:00 8.5 0.7 10.3 6.5 8.6 0.8 10.3 6.5 0.4 0 0.4 0.4 52 8 58 305 0 0 0 0 -5.5 0 -5.6 -5.8 11/05/2004 13:20:00 8.6 0.6 9.9 6.8 8.7 0.6 9.9 7.2 0.4 0 0.4 0.4 50 6 52 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/05/2004 13:30:00 8.1 1 10.3 6.1 8.1 0.9 10.3 6.1 0.4 0 0.4 0.4 51 6 51 305 0 0 0 0 -5.5 0 -5.3 -5.8 11/05/2004 13:40:00 7.8 0.7 9.5 6.1 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 53 7 41 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/05/2004 13:50:00 7.5 0.8 9.5 5.7 7.6 0.8 9.1 5.7 0.4 0 0.4 0.4 51 5 56 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/05/2004 14:00:00 7.2 1 9.5 5.3 7.2 1 9.9 5.3 0.4 0 0.4 0.4 51 9 53 305 0 0 0 0 -5.2 0 -5.1 -5.6 11/05/2004 14:10:00 7.6 0.7 9.9 5.7 7.6 0.8 10.7 5.7 0.4 0 0.4 0.4 54 9 49 305 0 0 0 0 -5.1 0 -4.9 -5.3 11/05/2004 14:20:00 7.5 0.7 9.5 5.7 7.6 0.8 9.5 5.7 0.4 0 0.4 0.4 48 7 42 305 0 0 0 0 -5 0 -4.9 -5.1 11/05/2004 14:30:00 6.8 0.8 9.1 4.9 6.7 0.9 8.4 4.6 0.4 0 0.4 0.4 55 10 65 305 0 0 0 0 -5 0 -4.7 -5.1 11/05/2004 14:40:00 7.2 0.8 9.1 5.3 7.2 0.8 9.1 5.3 0.4 0 0.4 0.4 48 6 49 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/05/2004 14:50:00 7.5 1.2 10.3 4.9 7.6 1.2 10.7 4.9 0.4 0 0.4 0.4 47 8 55 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/05/2004 15:00:00 7.4 0.9 9.9 5.7 7.5 1 9.9 5.7 0.4 0 0.4 0.4 46 8 37 305 0 0 0 0 -4.8 0 -4.7 -4.9 11/05/2004 15:10:00 8.1 0.8 10.3 6.5 8.2 0.8 10.7 6.5 0.4 0 0.4 0.4 39 8 36 305 0 0 0 0 -4.7 0 -4.5 -4.7 11/05/2004 15:20:00 8.9 0.8 11.1 6.5 8.9 0.9 11.1 6.5 0.4 0 0.4 0.4 38 8 39 305 0 0 0 0 -4.7 0 -4.5 -4.7 11/05/2004 15:30:00 8.2 0.8 9.9 5.7 8.3 0.9 10.7 5.7 0.4 0 0.4 0.4 42 9 50 305 0 0 0 0 -4.7 0 -4.5 -4.7 11/05/2004 15:40:00 7.5 0.7 9.1 5.3 7.6 0.7 9.1 5.7 0.4 0 0.4 0.4 39 6 38 305 0 0 0 0 -4.5 0 -4.5 -4.7 11/05/2004 15:50:00 7.2 0.8 9.1 4.9 7.3 0.9 9.5 5.3 0.4 0 0.4 0.4 38 8 37 305 0 0 0 0 -4.5 0 -4.5 -4.7 11/05/2004 16:00:00 7.3 0.9 11.1 5.7 7.3 1 10.3 5.7 0.4 0 0.4 0.4 37 9 48 305 0 0 0 0 -4.7 0 -4.5 -4.9 11/05/2004 16:10:00 7.9 1.2 10.3 4.6 7.9 1.2 9.9 4.6 0.4 0 0.4 0.4 27 6 30 305 0 0 0 0 -4.9 0.1 -4.5 -5.1 11/05/2004 16:20:00 8.8 0.8 10.7 6.8 8.9 0.8 11.1 6.8 0.4 0 0.4 0.4 44 5 46 305 0 0 0 0 -4.6 0 -4.2 -4.7 11/05/2004 16:30:00 8.3 0.9 10.7 6.8 8.3 0.9 10.3 6.5 0.4 0 0.4 0.4 47 6 51 305 0 0 0 0 -4.4 0 -4 -4.7 11/05/2004 16:40:00 8.6 0.6 10.3 6.8 8.5 0.7 10.3 6.8 0.4 0 0.4 0.4 61 7 60 305 0 0 0 0 -4.6 0.2 -4.2 -4.9 11/05/2004 16:50:00 9.2 0.9 11.8 7.2 9 1 11.8 6.8 0.4 0 0.4 0.4 63 7 48 305 0 0 0 0 -4.9 0 -4.7 -5.1 11/05/2004 17:00:00 8.9 0.7 11.1 7.2 8.9 0.8 11.5 7.2 0.4 0 0.4 0.4 57 8 54 305 0 0 0 0 -4.7 0.1 -4.5 -5.1 11/05/2004 17:10:00 9 0.6 10.7 6.8 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 56 4 56 305 0 0 0 0 -4.5 0 -4.2 -4.7 11/05/2004 17:20:00 8.7 0.9 10.7 6.5 8.6 1 11.1 6.5 0.4 0 0.4 0.4 61 8 65 305 0 0 0 0 -4.5 0 -4.2 -4.7 11/05/2004 17:30:00 8.4 0.9 10.3 6.1 8.3 1.1 10.3 4.9 0.4 0 0.4 0.4 62 5 64 305 0 0 0 0 -4.5 0 -4.5 -4.7 11/05/2004 17:40:00 8.7 0.7 10.7 7.2 8.6 0.8 10.7 6.5 0.4 0 0.4 0.4 63 6 65 305 0 0 0 0 -4.6 0 -4.5 -4.7 11/05/2004 17:50:00 9.7 0.9 11.8 7.6 9.7 0.9 11.8 7.6 0.4 0 0.4 0.4 57 4 58 305 0 0 0 0 -4.4 0 -4.2 -4.5 11/05/2004 18:00:00 10.7 1 13.3 8.8 10.8 1 13.7 8.4 0.4 0 0.4 0.4 54 5 61 305 0 0 0 0 -4.4 0 -3.8 -4.7 11/05/2004 18:10:00 11.4 0.6 12.6 9.5 11.4 0.7 12.6 9.1 0.4 0 0.4 0.4 57 6 56 305 0 0 0 0 -4.9 0.1 -4 -5.1 11/05/2004 18:20:00 11.2 0.8 12.6 8.8 11.3 0.9 13 8.8 0.4 0 0.4 0.4 58 5 62 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/05/2004 18:30:00 10.3 0.9 12.2 8 10.2 1 12.2 8.4 0.4 0 0.4 0.4 59 6 61 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/05/2004 18:40:00 9.9 0.9 12.2 7.6 10 1 12.2 7.2 0.4 0 0.4 0.4 53 9 43 305 0 0 0 0 -4.7 0 -4.5 -4.9 11/05/2004 18:50:00 10.6 0.7 12.2 8.8 10.6 0.8 12.2 8 0.4 0 0.4 0.4 57 5 53 305 0 0 0 0 -4.9 0.1 -4.5 -5.3 11/05/2004 19:00:00 11.3 0.8 13.3 9.5 11.3 0.9 13.7 8.8 0.4 0 0.4 0.4 64 4 59 305 0 0 0 0 -5.5 0.1 -4.7 -5.8 11/05/2004 19:10:00 10 0.8 12.2 7.2 10 0.9 12.2 7.2 0.4 0 0.4 0.4 63 13 72 305 0 0 0 0 -5.7 0.2 -5.3 -6 11/05/2004 19:20:00 9.2 0.8 11.5 6.8 9.3 0.8 11.5 6.8 0.4 0 0.4 0.4 51 4 57 305 0 0 0 0 -5.7 0.1 -5.6 -6 11/05/2004 19:30:00 9.6 1.2 12.6 6.1 9.6 1.2 12.2 6.5 0.4 0 0.4 0.4 39 11 42 305 0 0 0 0 -5.9 0.1 -5.6 -6.2 11/05/2004 19:40:00 11.2 2.5 15.3 6.1 11.2 2.5 14.9 6.1 0.4 0 0.4 0.4 43 13 54 305 0 0 0 0 -5.2 0.5 -4.5 -6 11/05/2004 19:50:00 13.5 0.8 15.6 11.5 13.5 1 15.6 11.1 0.4 0 0.4 0.4 46 6 44 305 0 0 0 0 -4.6 0 -4.5 -4.9 11/05/2004 20:00:00 13.9 1 16.1 11.5 13.9 1 16.1 10.7 0.4 0 0.4 0.4 46 5 46 305 0 0 0 0 -4.5 0 -4.2 -4.7 11/05/2004 20:10:00 13.6 1 16.4 11.1 13.5 1.1 16.4 10.3 0.4 0 0.4 0.4 43 6 44 305 1 0 1 0 -4.5 0 -4.2 -4.7 11/05/2004 20:20:00 13.4 1 16.4 10.3 13.3 1.1 16.4 10.3 0.4 0 0.4 0.4 40 6 37 305 1 0 1 0 -4.5 0 -4.2 -4.7 11/05/2004 20:30:00 13 0.8 14.9 11.1 13 0.9 15.3 10.7 0.4 0 0.4 0.4 41 5 40 305 1 0 1 0 -4.5 0 -4.2 -4.7 11/05/2004 20:40:00 13.2 0.9 16.1 11.1 13.1 1 15.6 11.1 0.4 0 0.4 0.4 40 5 45 305 1 0 1 0 -4.6 0 -4 -4.7 11/05/2004 20:50:00 12.9 0.8 14.9 10.7 12.8 0.8 14.5 10.3 0.4 0 0.4 0.4 36 6 45 305 1 0 1 0 -4.4 0 -4 -4.7 11/05/2004 21:00:00 12.9 0.9 15.3 11.1 12.9 1 15.3 10.3 0.4 0 0.4 0.4 37 5 48 305 1 0 1 0 -4.4 0 -4 -4.5 11/05/2004 21:10:00 13.6 0.9 16.4 11.5 13.6 0.9 16.4 10.7 0.4 0 0.4 0.4 34 5 42 305 1 0 0 0 -4.4 0 -4 -4.7 11/05/2004 21:20:00 13.4 0.9 15.3 10.7 13.3 0.9 15.6 10.3 0.4 0 0.4 0.4 33 6 30 305 1 0 1 0 -4.4 0 -4 -4.5 11/05/2004 21:30:00 14 1 16.8 11.5 14 1.1 17.6 11.5 0.4 0 0.4 0.4 33 4 35 305 0 0 0 0 -4.4 0 -4 -4.5 11/05/2004 21:40:00 14.1 0.9 16.8 11.8 14 1 16.4 11.5 0.4 0 0.4 0.4 36 6 44 305 0 0 0 0 -4.4 0 -4 -4.5 11/05/2004 21:50:00 13.6 1 15.6 10.7 13.5 1.1 16.1 10.7 0.4 0 0.4 0.4 41 5 40 305 0 0 0 0 -4.2 0.1 -4 -4.5 11/05/2004 22:00:00 14.1 0.9 16.1 11.5 14.1 1 16.4 11.5 0.4 0 0.7 0.4 38 4 38 305 0 0 0 0 -4.4 0 -3.8 -4.5 11/05/2004 22:10:00 14 0.9 16.1 11.1 13.9 1 16.4 11.1 0.4 0 0.4 0.4 40 6 35 305 0 0 0 0 -4.4 0 -4 -4.5 11/05/2004 22:20:00 14.4 1 17.2 11.8 14.4 1.1 17.6 11.8 0.4 0 0.4 0.4 39 6 39 305 0 0 0 0 -4.3 0 -4 -4.5 11/05/2004 22:30:00 14.3 1.1 17.2 11.5 14.3 1.2 17.6 11.5 0.4 0 0.4 0.4 40 5 41 305 0 0 0 0 -4.4 0 -4.2 -4.5 11/05/2004 22:40:00 14.3 0.9 16.4 11.8 14.3 0.9 16.4 11.8 0.4 0 0.4 0.4 41 5 47 305 0 0 0 0 -4.3 0 -4 -4.5 11/05/2004 22:50:00 14.1 0.8 16.1 11.5 14 0.9 16.1 11.1 0.4 0 0.4 0.4 36 5 37 305 0 0 0 0 -4.3 0 -4 -4.5 11/05/2004 23:00:00 13.9 1 16.1 11.1 13.8 1 16.4 10.7 0.4 0 0.4 0.4 39 6 44 305 0 0 0 0 -4.3 0 -3.8 -4.5 11/05/2004 23:10:00 13.7 1.3 17.2 10.7 13.7 1.3 17.2 10.7 0.4 0 0.4 0.4 36 5 34 305 0 0 0 0 -4.3 0 -4 -4.5 11/05/2004 23:20:00 13.7 1.2 16.4 11.1 13.8 1.2 16.1 11.1 0.4 0 0.4 0.4 31 6 36 305 0 0 0 0 -4.3 0 -4 -4.5 11/05/2004 23:30:00 13.7 1 15.6 10.7 13.6 1.1 15.6 10.7 0.4 0 0.4 0.4 33 4 41 305 0 0 0 0 -4.4 0 -4 -4.5 11/05/2004 23:40:00 13.6 0.9 15.6 10.7 13.6 1 15.6 10.7 0.4 0 0.4 0.4 35 5 31 305 0 0 0 0 -4.3 0 -3.8 -4.5 11/05/2004 23:50:00 13.8 1 16.4 10.7 13.8 1 16.4 10.7 0.4 0 0.4 0.4 35 7 27 305 0 0 0 0 -4.4 0 -4 -4.5 11/06/2004 00:00:00 13.9 0.8 15.6 11.5 13.9 0.8 16.4 11.8 0.4 0 0.4 0.4 35 6 40 305 0 0 0 0 -4.4 0 -3.8 -4.7 11/06/2004 00:10:00 13.4 1 16.4 9.9 13.4 1 16.1 10.3 0.4 0 0.4 0.4 29 6 23 305 0 0 0 0 -4.6 0 -4 -4.7 11/06/2004 00:20:00 13.4 1.2 17.2 10.3 13.3 1.3 17.2 10.3 0.4 0 0.4 0.4 28 7 19 305 0 0 0 0 -4.4 0 -4 -4.7 11/06/2004 00:30:00 14.1 1 17.2 11.8 14.1 1 17.9 11.5 0.4 0 0.4 0.4 24 5 14 305 0 0 0 0 -4.5 0 -4 -4.7 11/06/2004 00:40:00 14.1 1 17.2 11.5 14.2 1.1 17.2 11.5 0.4 0 0.4 0.4 23 6 29 305 0 0 0 0 -4.5 0 -4 -4.7 11/06/2004 00:50:00 14.3 1 16.8 11.5 14.1 1 17.2 11.5 0.4 0 0.4 0.4 27 5 22 305 0 0 0 0 -4.6 0.1 -4.5 -4.7 11/06/2004 01:00:00 14 0.9 16.1 11.8 14 1 16.4 11.5 0.4 0 0.4 0.4 27 4 23 305 0 0 0 0 -4.9 0 -4.5 -5.1 11/06/2004 01:10:00 14.2 1 16.8 11.5 14.2 1 16.8 11.5 0.4 0 0.4 0.4 26 4 32 305 0 0 0 0 -5 0 -4.7 -5.1 11/06/2004 01:20:00 13.3 1 15.3 11.1 13.3 1 15.3 10.3 0.4 0 0.4 0.4 26 4 27 305 0 0 0 0 -4.7 0.1 -4 -4.9 11/06/2004 01:30:00 14.8 1.2 17.2 11.1 14.7 1.3 17.6 11.1 0.4 0 0.4 0.4 25 5 24 305 0 0 0 0 -4.6 0 -4.2 -4.7 11/06/2004 01:40:00 15.3 1.2 17.9 11.5 15.3 1.2 17.9 11.5 0.4 0 0.4 0.4 18 3 20 305 0 0 0 0 -4.9 0.1 -4.2 -5.1 11/06/2004 01:50:00 14.8 1 17.2 11.8 15 1 17.2 11.8 0.4 0 0.4 0.4 18 6 14 305 0 0 0 0 -5 0 -4.5 -5.1 11/06/2004 02:00:00 15 1.2 17.9 11.5 15.1 1.2 17.9 11.5 0.4 0 0.4 0.4 16 4 9 305 0 0 0 0 -5.2 0.2 -4.7 -5.6 11/06/2004 02:10:00 14.9 1 17.2 11.8 15 1 17.2 12.2 0.4 0 0.4 0.4 17 5 18 305 0 0 1 0 -5.2 0 -4.7 -5.6 11/06/2004 02:20:00 14.7 1.1 17.2 11.8 14.7 1.2 17.2 11.8 0.4 0 0.4 0.4 17 4 17 305 1 0 1 0 -5.3 0.2 -4.9 -5.6 11/06/2004 02:30:00 13.8 1.2 16.8 9.9 13.9 1.3 17.2 10.3 0.4 0 0.4 0.4 15 5 9 305 1 0 1 0 -5.3 0.1 -4.7 -5.6 11/06/2004 02:40:00 14.2 1.1 16.8 11.5 14.3 1.2 17.2 11.1 0.4 0 0.4 0.4 15 4 11 305 1 0 1 0 -5.3 0.1 -4.7 -5.6 11/06/2004 02:50:00 14.5 1 17.2 11.5 14.6 1.1 17.6 11.1 0.4 0 0.4 0.4 12 4 17 305 1 0 1 0 -5.5 0.2 -4.5 -5.8 11/06/2004 03:00:00 14.7 1.1 17.9 11.5 14.8 1.2 17.9 11.1 0.4 0 0.4 0.4 11 5 14 305 1 0 1 0 -5.9 0 -5.6 -6.2 11/06/2004 03:10:00 14.4 0.9 16.8 12.2 14.6 1 17.2 11.8 0.4 0 0.4 0.4 16 4 16 305 1 0 1 0 -5.7 0 -5.6 -5.8 11/06/2004 03:20:00 13.7 1 16.1 9.9 13.8 1.1 16.4 10.7 0.4 0 0.4 0.4 18 5 17 305 1 0 1 0 -5.6 0 -5.6 -5.8 11/06/2004 03:30:00 13.8 1 16.4 10.3 13.9 1.1 16.8 10.3 0.4 0 0.4 0.4 16 4 16 305 1 0 1 0 -5.6 0 -5.6 -5.8 11/06/2004 03:40:00 13.1 1.1 16.1 10.3 13.2 1.2 16.4 10.7 0.4 0 0.4 0.4 16 6 7 305 1 0 1 0 -5.6 0 -5.3 -5.8 11/06/2004 03:50:00 13.3 1 15.3 10.3 13.4 1 15.6 10.7 0.4 0 0.4 0.4 15 5 18 305 1 0 1 0 -5.6 0 -5.3 -5.8 11/06/2004 04:00:00 13.3 0.9 16.1 11.1 13.4 1 16.8 11.1 0.4 0 0.4 0.4 14 5 12 305 1 0 1 0 -5.6 0 -4.9 -5.8 11/06/2004 04:10:00 13.8 1 16.8 11.1 13.9 1.1 16.8 11.5 0.4 0 0.4 0.4 14 5 9 305 1 0 1 0 -5.5 0 -4.7 -5.6 11/06/2004 04:20:00 14.1 0.9 16.1 11.1 14.3 0.9 16.4 11.5 0.4 0 0.4 0.4 14 4 21 305 1 0 1 0 -5.5 0.1 -4.7 -5.8 11/06/2004 04:30:00 13.9 1.1 15.6 10.7 14 1.1 16.4 11.1 0.4 0 0.4 0.4 12 4 7 305 2 0 2 0 -5.5 0 -5.1 -5.6 11/06/2004 04:40:00 13.8 1 16.4 11.5 13.7 1.1 16.4 10.7 0.4 0 0.4 0.4 13 4 18 305 2 1 4 0 -5.5 0 -4.9 -5.8 11/06/2004 04:50:00 13.5 1.1 15.6 9.5 13.7 1.1 15.6 9.9 0.4 0 0.4 0.4 12 5 11 305 4 0 3 0 -5.6 0 -4.9 -5.8 11/06/2004 05:00:00 12.6 1.2 16.1 9.5 12.7 1.2 16.4 9.5 0.4 0 0.4 0.4 14 5 10 305 3 0 3 0 -5.6 0.1 -5.3 -6 11/06/2004 05:10:00 14.5 1.9 18.7 9.9 14.6 1.9 19.5 9.9 0.4 0 0.4 0.4 9 5 8 305 3 0 4 0 -5.6 0 -5.3 -5.8 11/06/2004 05:20:00 16 1 18.7 13 16.1 1.1 18.7 12.6 0.4 0 0.4 0.4 7 4 8 305 4 1 3 0 -5.5 0 -5.1 -5.6 11/06/2004 05:30:00 14.8 1.2 17.2 10.7 14.9 1.2 17.6 11.1 0.4 0 0.4 0.4 7 5 3 305 5 0 5 0 -5.3 0 -5.1 -5.6 11/06/2004 05:40:00 14.7 1.3 17.6 11.8 14.8 1.5 17.9 11.5 0.4 0 0.4 0.4 5 4 3 305 4 0 5 0 -5.1 0 -4.9 -5.3 11/06/2004 05:50:00 15 1.1 17.2 11.1 15 1.2 17.2 11.5 0.4 0 0.4 0.4 7 5 2 305 4 0 4 0 -5.1 0.1 -4.7 -5.3 11/06/2004 06:00:00 14.8 1.1 17.2 11.5 14.9 1.1 17.6 11.5 0.4 0 0.4 0.4 5 5 12 305 4 0 4 0 -5.1 0 -4.9 -5.6 11/06/2004 06:10:00 14.1 1.1 17.9 11.8 14.2 1.1 17.9 11.8 0.4 0 0.4 0.4 2 4 1 305 5 0 5 0 -5.2 0 -4.9 -5.6 11/06/2004 06:20:00 15.2 1.3 17.6 10.7 15.4 1.3 17.9 11.1 0.4 0 0.4 0.4 359 3 2 305 5 0 5 0 -5.3 0 -4.9 -5.6 11/06/2004 06:30:00 16 1.3 19.1 13 16.1 1.4 19.5 13 0.4 0 0.4 0.4 356 4 356 305 5 0 5 0 -5 0 -4.7 -5.1 11/06/2004 06:40:00 13.9 1.2 17.2 11.1 14.1 1.2 17.9 11.1 0.4 0 0.4 0.4 358 5 355 305 3 0 3 0 -4.5 0 -4.2 -4.7 11/06/2004 06:50:00 12.8 1 14.9 9.9 12.8 1.1 15.3 9.1 0.4 0 0.4 0.4 5 7 8 305 3 0 2 0 -4.2 0 -3.8 -4.5 11/06/2004 07:00:00 13.1 1.3 16.4 9.9 13.4 1.2 16.4 10.3 0.4 0 0.4 0.4 359 5 2 305 3 0 2 0 -4.4 0 -4 -4.5 11/06/2004 07:10:00 11.9 1 14.9 10.3 12 1 15.3 9.1 0.4 0 0.4 0.4 18 7 10 305 3 0 3 0 -4 0 -3.8 -4 11/06/2004 07:20:00 12.1 0.9 13.7 9.5 12.3 1 14.1 9.5 0.4 0 0.4 0.4 13 5 14 305 3 0 3 0 -4 0 -3.8 -4.2 11/06/2004 07:30:00 12.6 2.2 16.8 8.4 12.8 2.1 17.2 8.8 0.4 0 0.4 0.4 24 20 38 305 3 0 3 0 -4.2 0 -3.8 -4.5 11/06/2004 07:40:00 15.8 1.9 19.9 12.2 15.7 2 19.5 12.2 0.4 0 0.4 0.4 33 14 18 305 3 0 3 0 -4.2 0.2 -3.8 -4.7 11/06/2004 07:50:00 16.6 1.2 19.5 13 16.5 1.3 19.1 13 0.4 0 0.4 0.4 23 5 23 305 3 0 3 0 -3.9 0 -3.6 -4 11/06/2004 08:00:00 17.5 1.1 19.9 14.5 17.5 1.2 20.2 14.1 0.4 0 0.4 0.4 29 7 23 305 3 0 4 0 -3.8 0.1 -3.3 -3.8 11/06/2004 08:10:00 17.8 1.3 21.4 14.5 17.7 1.3 21.4 13.7 0.4 0 0.4 0.4 28 8 14 305 4 0 4 0 -3.7 0.1 -3.1 -3.8 11/06/2004 08:20:00 17.1 1.5 19.9 13.3 16.9 1.5 20.2 13.3 0.4 0 0.4 0.4 23 7 18 305 3 0 4 0 -3.5 0.1 -2.7 -3.8 11/06/2004 08:30:00 16.4 1.5 20.2 12.2 16.4 1.6 19.9 12.6 0.4 0 0.4 0.4 26 6 27 305 4 0 4 0 -3.4 0 -2.7 -3.6 11/06/2004 08:40:00 17.3 1.5 20.2 14.1 17.4 1.5 20.2 13 0.4 0 0.4 0.4 21 4 20 305 4 0 4 0 -3.4 0.1 -2.7 -3.8 11/06/2004 08:50:00 16.7 1.3 20.2 13.7 16.7 1.3 20.6 13.3 0.4 0 0.4 0.4 13 7 19 305 4 0 4 0 -4.2 0.2 -3.3 -4.5 11/06/2004 09:00:00 18.2 1.6 21 13 18.1 1.7 21.8 12.6 0.4 0 0.4 0.4 3 5 6 305 4 0 4 0 -4.5 0 -3.8 -4.7 11/06/2004 09:10:00 18.7 1.8 22.9 14.1 18.7 1.9 23.3 13.3 0.4 0 0.4 0.4 0 5 353 305 4 0 4 0 -4.6 0 -4 -4.7 11/06/2004 09:20:00 18.5 1.2 22.6 15.3 18.6 1.3 22.9 15.3 0.4 0 0.4 0.4 0 5 354 305 4 0 4 0 -4.7 0.1 -4 -4.9 11/06/2004 09:30:00 19 1.6 22.6 14.1 19.1 1.7 22.9 14.9 0.4 0 0.4 0.4 358 4 358 305 4 0 4 0 -4.8 0 -4.5 -4.9 11/06/2004 09:40:00 18.7 1.9 22.6 13.7 18.8 2 22.9 13.7 0.4 0 0.4 0.4 358 4 359 305 4 0 4 0 -4.8 0.1 -4.5 -5.3 11/06/2004 09:50:00 18.3 1.5 22.1 14.5 18.5 1.5 22.6 14.5 0.4 0 0.4 0.4 358 4 0 305 4 0 4 0 -4.9 0 -4.5 -5.1 11/06/2004 10:00:00 18.9 1.7 23.3 14.9 19 1.6 22.9 14.9 0.4 0 0.4 0.4 358 4 356 305 4 0 4 0 -5 0 -4.5 -5.1 11/06/2004 10:10:00 18.7 1.6 22.1 13.3 18.8 1.7 22.6 14.1 0.4 0 0.4 0.4 356 4 352 305 4 0 4 0 -5.1 0.1 -4.7 -5.3 11/06/2004 10:20:00 19.1 1.4 22.1 15.3 19.2 1.5 22.6 14.9 0.4 0 0.4 0.4 356 4 2 305 4 0 4 0 -5.1 0.1 -4.5 -5.6 11/06/2004 10:30:00 19.1 1.6 22.6 14.5 19.1 1.7 22.9 14.5 0.4 0 0.4 0.4 358 4 358 305 4 0 4 0 -5.2 0 -4.9 -5.6 11/06/2004 10:40:00 18.9 1.7 22.6 14.9 18.9 1.7 22.6 14.5 0.4 0 0.4 0.4 2 4 2 305 4 0 4 0 -4.9 0 -4.7 -5.1 11/06/2004 10:50:00 18.6 1.6 21.8 14.5 18.6 1.7 22.6 14.5 0.4 0 0.4 0.4 2 5 4 305 4 0 4 0 -5 0.1 -4.5 -5.1 11/06/2004 11:00:00 19.3 1.5 22.9 15.3 19.3 1.5 22.6 14.5 0.4 0 0.4 0.4 3 4 6 305 4 0 4 0 -5 0 -4.7 -5.1 11/06/2004 11:10:00 19.7 1.5 22.6 15.3 19.7 1.5 22.9 15.6 0.4 0 0.4 0.4 2 4 354 305 4 0 4 0 -5.1 0.1 -4.7 -5.6 11/06/2004 11:20:00 19.6 1.5 22.9 16.1 19.6 1.7 23.7 16.1 0.4 0 0.4 0.4 2 4 2 305 4 0 4 0 -5.1 0 -4.9 -5.3 11/06/2004 11:30:00 18.8 1.6 22.6 15.3 18.8 1.7 22.6 14.5 0.4 0 0.4 0.4 4 4 3 305 4 0 4 0 -5 0 -4.9 -5.3 11/06/2004 11:40:00 19.3 1.4 22.6 15.3 19.3 1.5 22.6 15.6 0.4 0 0.4 0.4 0 4 359 305 4 0 4 0 -5.1 0 -4.7 -5.3 11/06/2004 11:50:00 19.8 1.3 22.9 15.3 19.7 1.4 23.3 15.6 0.4 0 0.4 0.4 3 5 2 305 4 0 4 0 -5.2 0 -5.1 -5.6 11/06/2004 12:00:00 19.9 1.7 23.3 14.9 19.8 1.9 23.7 15.3 0.4 0 0.4 0.4 2 5 357 305 3 0 4 0 -5.1 0 -4.7 -5.3 11/06/2004 12:10:00 18.6 1.7 22.1 14.1 18.6 1.7 22.9 14.1 0.4 0 0.4 0.4 3 4 5 305 4 0 4 0 -5 0 -4.7 -5.1 11/06/2004 12:20:00 20.3 1.5 23.3 14.9 20.1 1.5 23.7 16.1 0.4 0 0.4 0.4 3 5 4 305 4 0 4 0 -5.1 0 -4.5 -5.3 11/06/2004 12:30:00 19.8 1.6 23.3 14.9 19.7 1.7 22.9 14.5 0.4 0 0.4 0.4 2 5 2 305 4 0 4 0 -5.1 0 -4.7 -5.6 11/06/2004 12:40:00 19.6 1.5 22.9 14.5 19.5 1.6 23.3 15.3 0.4 0 0.4 0.4 4 4 5 305 4 0 4 0 -5.1 0 -4.9 -5.6 11/06/2004 12:50:00 18.4 1.5 21.4 13.7 18.4 1.6 21.8 13.3 0.4 0 0.4 0.4 0 5 0 305 4 0 4 0 -5.2 0.1 -4.9 -5.6 11/06/2004 13:00:00 18.9 1.5 21.8 14.9 18.7 1.5 22.1 14.9 0.4 0 0.4 0.4 359 5 355 305 4 0 4 0 -5.3 0.1 -4.7 -5.6 11/06/2004 13:10:00 18.5 1.7 22.9 14.5 18.5 1.8 22.9 14.1 0.4 0 0.4 0.4 1 5 353 305 3 0 4 0 -5.3 0.1 -4.9 -5.6 11/06/2004 13:20:00 18.7 1.7 23.3 15.3 18.7 1.7 23.7 14.5 0.4 0 0.4 0.4 2 5 2 305 3 0 4 0 -5.4 0.1 -5.1 -5.8 11/06/2004 13:30:00 18.7 1.6 22.1 14.1 18.7 1.6 22.6 14.9 0.4 0 0.4 0.4 1 4 358 305 4 0 4 0 -5.4 0.1 -5.1 -5.6 11/06/2004 13:40:00 18.8 1.5 22.1 14.1 18.8 1.5 21.8 14.9 0.4 0 0.4 0.4 358 4 357 305 3 0 4 0 -5.6 0 -5.6 -5.8 11/06/2004 13:50:00 19 1.3 22.1 15.6 19 1.4 22.6 15.3 0.4 0 0.4 0.4 1 5 6 305 3 0 4 0 -5.6 0.1 -5.1 -5.8 11/06/2004 14:00:00 18.5 1.5 22.1 14.1 18.5 1.6 22.1 14.5 0.4 0 0.4 0.4 0 5 2 305 4 0 4 0 -5.5 0 -5.1 -5.8 11/06/2004 14:10:00 19 1.7 23.3 14.9 19.1 1.7 23.3 14.9 0.4 0 0.4 0.4 1 5 359 305 4 0 4 0 -5.6 0 -5.3 -5.8 11/06/2004 14:20:00 19.3 1.4 23.7 14.9 19.3 1.5 23.3 15.3 0.4 0 0.4 0.4 4 5 5 305 4 0 4 0 -5.6 0 -5.6 -5.8 11/06/2004 14:30:00 19.7 1.5 22.9 15.6 19.6 1.5 23.3 15.6 0.4 0 0.4 0.4 7 4 8 305 4 0 4 0 -5.6 0 -5.3 -5.8 11/06/2004 14:40:00 19.3 1.8 22.9 14.1 19.2 1.8 22.9 13.7 0.4 0 0.4 0.4 5 5 8 305 4 0 4 0 -5.6 0 -5.3 -5.8 11/06/2004 14:50:00 19.1 1.5 22.6 14.9 19.1 1.5 22.6 14.9 0.4 0 0.4 0.4 3 4 4 305 4 0 4 0 -5.6 0.1 -5.1 -6 11/06/2004 15:00:00 19.8 1.5 22.6 15.6 19.7 1.5 22.6 15.3 0.4 0 0.4 0.4 1 5 7 305 4 0 4 0 -5.9 0 -5.6 -6 11/06/2004 15:10:00 19.5 1.5 22.1 14.9 19.4 1.5 22.6 15.3 0.4 0 0.4 0.4 2 5 7 305 4 0 4 0 -5.9 0 -5.6 -6 11/06/2004 15:20:00 19.1 1.5 23.3 15.3 19.1 1.5 22.6 14.9 0.4 0 0.4 0.4 0 5 2 305 4 0 4 0 -6 0 -5.6 -6.2 11/06/2004 15:30:00 19.4 1.5 23.3 14.9 19.4 1.5 22.9 15.6 0.4 0 0.4 0.4 1 5 7 305 4 0 4 0 -6.1 0 -5.8 -6.2 11/06/2004 15:40:00 19.5 1.2 22.1 15.3 19.4 1.2 22.1 15.3 0.4 0 0.4 0.4 2 4 8 305 4 0 4 0 -6 0 -5.8 -6.2 11/06/2004 15:50:00 18.5 1.5 21.8 13.7 18.6 1.5 22.1 14.1 0.4 0 0.4 0.4 0 4 355 305 4 0 4 0 -6 0 -5.8 -6.2 11/06/2004 16:00:00 18.1 1.3 20.6 14.1 18 1.4 20.6 13.7 0.4 0 0.4 0.4 6 5 5 305 4 0 4 0 -5.7 0 -5.6 -6 11/06/2004 16:10:00 18.8 1.7 22.9 14.5 19 1.7 23.3 14.1 0.4 0 0.4 0.4 6 4 4 305 4 0 4 0 -5.7 0 -5.6 -6 11/06/2004 16:20:00 18.8 1.3 21.4 15.3 18.9 1.3 21.8 15.6 0.4 0 0.4 0.4 6 5 1 305 4 0 4 0 -5.8 0 -5.6 -6 11/06/2004 16:30:00 18.9 1.2 21.4 15.3 18.9 1.4 21.4 14.5 0.4 0 0.4 0.4 3 4 1 305 4 0 4 0 -5.8 0.1 -5.6 -6.2 11/06/2004 16:40:00 18.1 1.6 21.8 13.7 18.1 1.7 21.4 14.1 0.4 0 0.4 0.4 7 4 9 305 4 0 4 0 -5.7 0 -5.6 -6 11/06/2004 16:50:00 18.8 1.7 21.8 13.7 18.9 1.7 22.1 13.3 0.4 0 0.4 0.4 8 4 13 305 4 0 4 0 -5.7 0.2 -5.3 -6 11/06/2004 17:00:00 19.4 1.5 22.6 13.7 19.5 1.6 22.9 14.9 0.4 0 0.4 0.4 4 5 5 305 4 0 4 0 -5.7 0 -5.1 -6 11/06/2004 17:10:00 19 1.2 22.1 16.1 18.9 1.3 21.8 15.3 0.4 0 0.4 0.4 4 5 5 305 4 0 4 0 -5.6 0 -5.3 -5.8 11/06/2004 17:20:00 18.4 1.4 21.4 14.9 18.5 1.5 21.8 14.9 0.4 0 0.4 0.4 1 4 1 305 4 0 4 0 -5.6 0 -5.6 -5.8 11/06/2004 17:30:00 18.4 1.5 21.8 13.3 18.5 1.5 22.1 14.1 0.4 0 0.4 0.4 0 5 3 305 4 0 4 0 -5.6 0 -5.3 -5.8 11/06/2004 17:40:00 18.2 1.6 21.8 14.1 18.3 1.6 21.8 14.1 0.4 0 0.4 0.4 1 5 346 305 4 0 4 0 -5.6 0 -5.3 -5.8 11/06/2004 17:50:00 18.7 1.7 21.8 13.7 18.7 1.8 22.6 13.7 0.4 0 0.4 0.4 2 4 3 305 4 0 4 0 -5.6 0 -5.1 -5.8 11/06/2004 18:00:00 18.1 1.6 21.4 12.6 18.1 1.6 21.4 13.7 0.4 0 0.4 0.4 3 4 4 305 4 0 4 0 -5.5 0.1 -5.1 -5.8 11/06/2004 18:10:00 17.8 1.5 21 13.3 18 1.6 21.8 13 0.4 0 0.4 0.4 358 5 347 305 4 0 4 0 -5.7 0.1 -5.1 -6 11/06/2004 18:20:00 17.6 1.2 21 13.7 17.8 1.4 21.8 13.7 0.4 0 0.4 0.4 357 5 351 305 4 0 4 0 -5.7 0 -5.3 -6 11/06/2004 18:30:00 18.4 1.6 21.4 14.1 18.5 1.7 22.1 13 0.4 0 0.4 0.4 357 5 0 305 4 0 4 0 -5.6 0 -5.3 -6 11/06/2004 18:40:00 18.4 1.7 21.8 13.3 18.5 1.7 22.6 13.7 0.4 0 0.4 0.4 359 5 359 305 4 0 4 0 -5.6 0 -5.3 -5.8 11/06/2004 18:50:00 17.8 1.7 22.1 13 17.9 1.7 22.6 13.7 0.4 0 0.4 0.4 358 5 357 305 4 0 4 0 -5.7 0 -5.6 -6 11/06/2004 19:00:00 18.4 1.3 21.4 14.1 18.5 1.3 21.8 14.9 0.4 0 0.4 0.4 358 4 359 305 4 0 4 0 -5.8 0 -5.6 -6 11/06/2004 19:10:00 17.7 1.7 21 12.6 17.9 1.7 21.4 12.2 0.4 0 0.4 0.4 357 5 355 305 4 0 4 0 -5.6 0 -5.3 -5.8 11/06/2004 19:20:00 17.1 1.3 20.2 13 17.3 1.3 21 13.7 0.4 0 0.4 0.4 2 5 0 305 4 0 4 0 -5.5 0.2 -5.1 -5.8 11/06/2004 19:30:00 18.2 1.3 20.6 13 18.3 1.5 21 12.2 0.4 0 0.4 0.4 4 4 7 305 4 0 4 0 -5.5 0 -5.1 -5.6 11/06/2004 19:40:00 17.6 1.3 20.6 13.3 17.9 1.4 21.8 13.7 0.4 0 0.4 0.4 3 5 357 305 4 0 4 0 -5.5 0 -5.1 -5.8 11/06/2004 19:50:00 17.2 1.4 19.9 13.7 17.3 1.5 21 13 0.4 0 0.4 0.4 2 5 2 305 4 0 4 0 -5.3 0.1 -4.9 -5.6 11/06/2004 20:00:00 17.1 1.5 20.6 13.3 17.2 1.5 21 13 0.4 0 0.4 0.4 3 4 357 305 4 0 4 0 -5.2 0.1 -4.7 -5.6 11/06/2004 20:10:00 17 1.3 20.2 13.3 17.1 1.4 21 13.3 0.4 0 0.4 0.4 1 4 357 305 4 0 4 0 -5.4 0 -4.9 -5.6 11/06/2004 20:20:00 17.6 1.4 20.6 13.3 17.8 1.5 20.6 12.6 0.4 0 0.4 0.4 355 4 356 305 4 0 4 0 -5.5 0.1 -5.1 -5.8 11/06/2004 20:30:00 16.9 1.2 19.5 13.3 17.1 1.3 19.9 13 0.4 0 0.4 0.4 357 5 351 305 4 0 4 0 -5.3 0 -4.7 -5.6 11/06/2004 20:40:00 16.9 1.4 19.9 13.7 17 1.4 20.6 13.3 0.4 0 0.4 0.4 357 4 354 305 4 0 4 0 -5.4 0.1 -4.7 -5.6 11/06/2004 20:50:00 17 1.4 19.9 13 17.1 1.5 19.9 13.3 0.4 0 0.4 0.4 2 4 2 305 4 0 4 0 -5.3 0.1 -4.9 -5.6 11/06/2004 21:00:00 17.4 1.3 20.2 13.7 17.5 1.3 20.6 14.1 0.4 0 0.4 0.4 1 5 355 305 4 0 4 0 -5.3 0 -4.7 -5.6 11/06/2004 21:10:00 18.1 1.5 21 13.7 18.1 1.5 20.6 13.3 0.4 0 0.4 0.4 2 4 3 305 4 0 4 0 -5.3 0.1 -4.9 -5.6 11/06/2004 21:20:00 17.8 1.4 21.8 13.7 17.8 1.5 22.1 14.5 0.4 0 0.4 0.4 359 5 4 305 4 0 4 0 -5.3 0.1 -5.1 -5.6 11/06/2004 21:30:00 18.3 1.4 21 13.3 18.4 1.5 21.4 13 0.4 0 0.4 0.4 359 5 356 305 4 0 4 0 -5.4 0 -5.1 -5.6 11/06/2004 21:40:00 18.3 1.3 21 13.3 18.4 1.5 21.4 13 0.4 0 0.4 0.4 1 4 355 305 5 0 5 0 -5.4 0 -5.1 -5.6 11/06/2004 21:50:00 17.8 1.6 21 13.3 17.9 1.6 21.4 13.3 0.4 0 0.4 0.4 1 5 2 305 4 0 5 0 -5.5 0 -5.1 -5.8 11/06/2004 22:00:00 18.3 1.4 21 14.1 18.3 1.4 21.8 15.3 0.4 0 0.4 0.4 1 4 3 305 5 0 5 0 -5.5 0 -4.9 -5.8 11/06/2004 22:10:00 17.6 1.6 21 13 17.7 1.6 21.8 13 0.4 0 0.4 0.4 1 5 356 305 5 0 5 0 -5.2 0.1 -4.7 -5.6 11/06/2004 22:20:00 17.5 1.4 20.6 13.7 17.7 1.4 21.4 14.1 0.4 0 0.4 0.4 1 5 9 305 5 0 5 0 -5 0 -4.7 -5.3 11/06/2004 22:30:00 18.4 1.5 21.4 13.7 18.6 1.5 21.8 14.1 0.4 0 0.4 0.4 359 5 356 305 5 0 5 0 -5.1 0 -4.9 -5.3 11/06/2004 22:40:00 18.3 1.5 21.8 13.7 18.4 1.7 22.6 13.3 0.4 0 0.4 0.4 1 5 350 305 5 0 5 0 -5.2 0 -4.9 -5.6 11/06/2004 22:50:00 18.5 1.6 21.8 12.6 18.5 1.6 22.1 14.1 0.4 0 0.4 0.4 1 5 1 305 5 0 5 0 -5.2 0 -4.9 -5.6 11/06/2004 23:00:00 17.9 1.5 21.8 13.7 18 1.5 21.4 13.3 0.4 0 0.4 0.4 1 5 2 305 5 0 5 0 -5.2 0 -4.9 -5.6 11/06/2004 23:10:00 18.7 1.5 21.8 15.3 18.9 1.5 22.1 14.5 0.4 0 0.4 0.4 358 4 358 305 4 0 5 0 -5.2 0 -5.1 -5.6 11/06/2004 23:20:00 18.8 1.7 22.6 14.9 18.8 1.7 22.9 14.1 0.4 0 0.4 0.4 0 4 357 305 4 0 4 0 -5.3 0.1 -5.1 -5.6 11/06/2004 23:30:00 18.2 1.3 21 14.5 18 1.4 21.4 13.7 0.4 0 0.4 0.4 2 5 6 305 4 0 4 0 -5.2 0.1 -4.9 -5.6 11/06/2004 23:40:00 18.1 1.7 21.8 13.7 18.1 1.7 22.1 14.1 0.4 0 0.4 0.4 2 5 3 305 4 0 4 0 -5.3 0 -4.9 -5.6 11/06/2004 23:50:00 18.7 1.6 21.8 14.1 18.7 1.7 22.1 14.1 0.4 0 0.4 0.4 1 4 1 305 4 0 4 0 -5.3 0.1 -4.9 -5.6 11/07/2004 00:00:00 18.7 1.5 22.1 14.5 18.8 1.5 22.6 14.5 0.4 0 0.4 0.4 2 5 3 305 4 0 4 0 -5.4 0 -4.9 -5.6 11/07/2004 00:10:00 18.7 2 22.9 13.7 18.8 2 22.9 13.3 0.4 0 0.4 0.4 3 5 5 305 4 0 4 0 -5.3 0.1 -4.9 -5.6 11/07/2004 00:20:00 19.6 1.4 22.6 15.3 19.6 1.5 22.1 15.3 0.4 0 0.4 0.4 3 4 6 305 4 0 4 0 -5.4 0 -5.1 -5.6 11/07/2004 00:30:00 19.2 1.1 21.8 15.6 19.2 1.2 22.1 16.1 0.4 0 0.4 0.4 3 3 3 305 4 0 4 0 -5.4 0 -5.1 -5.6 11/07/2004 00:40:00 18.6 1.7 22.9 13.3 18.6 1.7 22.9 13.3 0.4 0 0.4 0.4 3 5 4 305 4 0 4 0 -5.2 0.1 -4.9 -5.6 11/07/2004 00:50:00 18.6 1.7 22.6 13.7 18.6 1.8 22.9 14.1 0.4 0 0.4 0.4 3 5 2 305 4 0 4 0 -5.2 0 -4.9 -5.6 11/07/2004 01:00:00 18.8 1.4 21.8 14.9 18.9 1.4 22.9 15.3 0.4 0 0.4 0.4 5 5 3 305 4 0 4 0 -5.2 0 -5.1 -5.6 11/07/2004 01:10:00 18.6 1.7 22.1 14.5 18.6 1.7 22.6 14.1 0.4 0 0.4 0.4 5 5 2 305 4 0 4 0 -5.1 0 -4.9 -5.3 11/07/2004 01:20:00 18.8 1.6 22.6 14.1 18.9 1.6 22.1 14.1 0.4 0 0.4 0.4 3 4 5 305 4 0 4 0 -5.2 0 -4.7 -5.3 11/07/2004 01:30:00 18.2 1.3 21 14.1 18.3 1.4 21 14.1 0.4 0 0.4 0.4 2 5 6 305 4 0 4 0 -5.2 0 -5.1 -5.6 11/07/2004 01:40:00 18.7 1.2 21.8 15.6 18.7 1.4 22.1 14.9 0.4 0 0.4 0.4 2 4 3 305 4 0 4 0 -5.2 0.1 -4.9 -5.6 11/07/2004 01:50:00 17.9 1.7 21.4 13.7 17.9 1.7 22.6 13.7 0.4 0 0.4 0.4 359 5 2 305 4 0 4 0 -5.4 0 -5.1 -5.6 11/07/2004 02:00:00 17.6 1.7 21 13.3 17.6 1.7 21.8 12.6 0.4 0 0.4 0.4 358 5 358 305 4 0 4 0 -5.4 0 -5.1 -5.6 11/07/2004 02:10:00 18.5 1.6 21.8 13.3 18.5 1.6 22.1 13.7 0.4 0 0.4 0.4 357 4 0 305 4 0 4 0 -5.5 0 -5.1 -5.6 11/07/2004 02:20:00 18.5 1.7 22.1 14.1 18.5 1.7 22.9 13.3 0.4 0 0.4 0.4 359 4 358 305 4 0 4 0 -5.5 0 -5.1 -5.8 11/07/2004 02:30:00 18.4 1.3 21.4 14.9 18.4 1.3 21.8 14.1 0.4 0 0.4 0.4 359 4 354 305 4 0 4 0 -5.3 0 -5.1 -5.6 11/07/2004 02:40:00 18.6 1.5 21.8 14.5 18.6 1.6 21.8 14.5 0.4 0 0.4 0.4 357 5 4 305 4 0 4 0 -5.3 0 -5.1 -5.6 11/07/2004 02:50:00 19.3 1.3 22.9 15.3 19.3 1.5 22.9 14.5 0.4 0 0.4 0.4 356 4 356 305 4 0 4 0 -5.4 0 -5.1 -5.8 11/07/2004 03:00:00 18.7 1.5 22.1 14.9 18.7 1.5 21.8 14.5 0.4 0 0.4 0.4 354 4 352 305 4 0 4 0 -5.5 0 -5.1 -5.8 11/07/2004 03:10:00 19 1.5 22.1 14.1 18.9 1.5 22.1 14.5 0.4 0 0.4 0.4 356 4 359 305 4 0 4 0 -5.5 0.1 -4.9 -5.8 11/07/2004 03:20:00 18.4 1.6 21.8 13.7 18.3 1.6 22.6 14.5 0.4 0 0.4 0.4 355 4 352 305 4 0 4 0 -5.3 0.1 -4.9 -5.6 11/07/2004 03:30:00 19.1 1.3 21.8 14.5 19 1.3 22.1 14.9 0.4 0 0.4 0.4 354 4 348 305 4 0 4 0 -5.4 0.1 -4.9 -5.6 11/07/2004 03:40:00 18.7 1.5 22.6 14.9 18.7 1.6 22.6 14.5 0.4 0 0.4 0.4 353 5 357 305 4 0 4 0 -5.3 0.1 -4.7 -5.6 11/07/2004 03:50:00 19 1.5 22.6 14.9 19 1.6 22.9 14.5 0.4 0 0.4 0.4 352 4 1 305 4 0 4 0 -5.4 0 -5.1 -5.6 11/07/2004 04:00:00 19.7 1.4 22.9 15.6 19.7 1.5 23.3 14.9 0.4 0 0.4 0.4 350 4 356 305 4 0 4 0 -5.5 0 -5.1 -5.8 11/07/2004 04:10:00 19.8 1.5 23.3 16.1 19.8 1.5 23.3 15.6 0.4 0 0.4 0.4 351 5 355 305 4 0 4 0 -5.5 0 -5.1 -5.6 11/07/2004 04:20:00 20 1.8 24.4 15.3 19.9 1.9 24 14.9 0.4 0 0.4 0.4 351 4 354 305 4 0 4 0 -5.5 0 -5.3 -5.8 11/07/2004 04:30:00 19.2 1.4 22.6 14.5 19.2 1.5 22.1 13.7 0.4 0 0.4 0.4 350 4 357 305 4 0 4 0 -5.5 0 -5.3 -5.6 11/07/2004 04:40:00 19.4 1.3 22.6 15.6 19.3 1.5 22.6 15.3 0.4 0 0.4 0.4 354 4 357 305 4 0 4 0 -5.5 0 -5.1 -5.8 11/07/2004 04:50:00 19.5 1.5 22.1 14.5 19.5 1.4 22.6 16.1 0.4 0 0.4 0.4 355 5 358 305 4 0 4 0 -5.5 0 -5.3 -5.8 11/07/2004 05:00:00 19.4 1.3 22.6 15.6 19.4 1.5 22.6 15.6 0.4 0 0.4 0.4 354 4 355 305 4 0 4 0 -5.7 0.1 -5.1 -6 11/07/2004 05:10:00 19.6 1.3 22.9 15.6 19.3 1.5 23.3 15.3 0.4 0 0.4 0.4 355 4 355 305 4 0 4 0 -5.7 0 -5.1 -5.8 11/07/2004 05:20:00 19.4 1.7 24 14.9 19.3 1.8 24 14.5 0.4 0 0.4 0.4 356 5 356 305 4 0 4 0 -5.4 0.1 -4.7 -5.6 11/07/2004 05:30:00 19.3 1.5 22.9 14.5 19.3 1.7 22.9 14.1 0.4 0 0.4 0.4 355 5 352 305 4 0 4 0 -5.5 0 -4.9 -5.8 11/07/2004 05:40:00 19.4 1.7 22.9 14.9 19.4 1.7 22.6 14.5 0.4 0 0.4 0.4 352 4 351 305 4 0 4 0 -5.6 0.1 -5.3 -6 11/07/2004 05:50:00 19.7 1.7 24 14.5 19.6 1.7 24.8 14.5 0.4 0 0.4 0.4 354 5 348 305 4 0 4 0 -5.6 0 -5.3 -5.8 11/07/2004 06:00:00 19.3 1.7 22.9 13.7 19.2 1.9 23.3 13.3 0.4 0 0.4 0.4 356 5 358 305 4 0 4 0 -5.6 0 -4.9 -5.8 11/07/2004 06:10:00 19.5 1.7 23.3 15.6 19.5 1.7 23.3 15.3 0.4 0 0.4 0.4 355 5 357 305 4 0 4 0 -5.6 0.1 -4.9 -5.8 11/07/2004 06:20:00 19 1.7 22.1 14.1 19.1 1.7 22.6 14.5 0.4 0 0.4 0.4 357 5 357 305 4 0 4 0 -5.6 0.1 -5.1 -5.8 11/07/2004 06:30:00 19.1 1.4 22.6 14.5 19 1.5 22.6 14.5 0.4 0 0.4 0.4 357 4 354 305 4 0 4 0 -5.5 0 -4.9 -5.8 11/07/2004 06:40:00 18.1 1.4 21 14.5 18 1.5 21.4 14.1 0.4 0 0.4 0.4 358 4 2 305 4 0 4 0 -5.6 0 -5.1 -5.8 11/07/2004 06:50:00 18.6 1.5 22.1 14.9 18.5 1.6 21.8 13.7 0.4 0 0.4 0.4 356 5 0 305 3 0 4 0 -5.7 0 -5.1 -5.8 11/07/2004 07:00:00 18.6 1.4 21.8 14.5 18.6 1.5 21.8 14.1 0.4 0 0.4 0.4 0 5 356 305 3 0 3 0 -5.7 0 -5.1 -6 11/07/2004 07:10:00 18.3 1.5 21.4 13 18.3 1.6 21.4 12.6 0.4 0 0.4 0.4 2 6 3 305 3 0 4 0 -5.7 0.1 -5.1 -6 11/07/2004 07:20:00 18.8 1.5 22.1 14.1 18.9 1.5 22.9 14.9 0.4 0 0.4 0.4 0 5 358 305 3 0 4 0 -5.9 0.1 -5.1 -6.2 11/07/2004 07:30:00 18.7 1.7 22.1 13.7 18.8 1.7 22.1 13.7 0.4 0 0.4 0.4 0 5 0 305 3 0 4 0 -5.8 0.1 -5.1 -6 11/07/2004 07:40:00 18.3 1.5 21.4 13.7 18.2 1.6 21.4 14.9 0.4 0 0.4 0.4 358 5 357 305 3 0 3 0 -5.8 0.1 -5.3 -6.2 11/07/2004 07:50:00 18.1 1.5 22.1 13.3 18.2 1.5 22.9 14.1 0.4 0 0.4 0.4 0 5 358 305 3 0 3 0 -5.9 0.1 -5.3 -6 11/07/2004 08:00:00 18.4 1.7 22.1 13 18.4 1.7 22.6 13.3 0.4 0 0.4 0.4 0 5 356 305 3 0 3 0 -5.9 0 -5.8 -6.2 11/07/2004 08:10:00 18.2 1.3 22.9 14.5 18.2 1.4 21 14.5 0.4 0 0.4 0.4 359 5 5 305 3 0 3 0 -6 0 -5.8 -6.2 11/07/2004 08:20:00 18.7 1.7 23.3 13.7 18.8 1.7 23.7 14.1 0.4 0 0.4 0.4 359 5 5 305 3 0 4 0 -5.9 0 -5.6 -6.2 11/07/2004 08:30:00 18.6 1.4 21.4 14.1 18.6 1.5 21.8 14.5 0.4 0 0.4 0.4 358 5 359 305 3 0 3 0 -6 0 -5.8 -6.2 11/07/2004 08:40:00 19 1.5 22.1 14.9 18.9 1.7 21.8 13.7 0.4 0 0.4 0.4 354 4 356 305 3 0 3 0 -6.1 0 -6 -6.4 11/07/2004 08:50:00 18.3 1.3 21 13.7 18.4 1.4 21.4 14.1 0.4 0 0.4 0.4 358 5 359 305 3 0 3 0 -6.1 0 -5.8 -6.2 11/07/2004 09:00:00 18 1.7 21.8 14.1 18.1 1.7 21.8 14.1 0.4 0 0.4 0.4 357 5 354 305 3 0 3 0 -6.1 0 -5.8 -6.2 11/07/2004 09:10:00 18.1 1.5 21.4 13.7 18.2 1.6 21.8 13.3 0.4 0 0.4 0.4 355 4 357 305 3 0 3 0 -6.1 0 -5.8 -6.4 11/07/2004 09:20:00 17.5 1.7 20.6 12.6 17.6 1.7 21.4 13.3 0.4 0 0.4 0.4 357 5 350 305 3 0 3 0 -6.1 0 -5.8 -6.2 11/07/2004 09:30:00 17.6 1.5 21 14.1 17.8 1.7 21.4 13.7 0.4 0 0.4 0.4 1 4 3 305 3 0 3 0 -6.2 0.1 -5.6 -6.4 11/07/2004 09:40:00 18 1.4 21 13.3 18.1 1.5 21.4 13 0.4 0 0.4 0.4 358 5 9 305 3 0 3 0 -6.2 0 -5.8 -6.4 11/07/2004 09:50:00 17.3 1.5 21.8 13 17.5 1.5 21.4 12.6 0.4 0 0.4 0.4 0 5 359 305 3 0 3 0 -6.2 0 -5.6 -6.4 11/07/2004 10:00:00 17.2 1.4 20.6 13 17.4 1.5 21 13.7 0.4 0 0.4 0.4 0 5 2 305 3 0 3 0 -6.4 0.1 -6 -6.7 11/07/2004 10:10:00 17.3 1.5 21.4 13.3 17.4 1.6 21.4 13 0.4 0 0.4 0.4 4 5 2 305 3 0 3 0 -6.5 0 -6.2 -6.7 11/07/2004 10:20:00 16.7 1.2 19.1 13 16.9 1.3 19.5 12.6 0.4 0 0.4 0.4 2 4 359 305 3 0 3 0 -6.6 0 -6.2 -6.9 11/07/2004 10:30:00 16.7 1.6 19.9 11.1 16.8 1.7 20.6 11.1 0.4 0 0.4 0.4 6 5 358 305 3 0 3 0 -6.6 0 -6.2 -6.9 11/07/2004 10:40:00 16.9 1.2 19.9 13.3 16.9 1.2 20.2 13.7 0.4 0 0.4 0.4 8 4 10 305 3 0 3 0 -6.5 0 -6.4 -6.9 11/07/2004 10:50:00 16.3 1.6 19.9 11.5 16.5 1.5 19.5 12.2 0.4 0 0.4 0.4 5 6 1 305 3 0 3 0 -6.6 0 -6.2 -6.9 11/07/2004 11:00:00 17.1 1.3 20.2 11.5 17.1 1.3 20.2 11.8 0.4 0 0.4 0.4 4 6 7 305 3 0 3 0 -6.8 0.1 -6.4 -6.9 11/07/2004 11:10:00 16.1 1.5 20.2 12.6 16.2 1.6 20.2 12.6 0.4 0 0.4 0.4 2 5 4 305 3 0 3 0 -6.8 0.1 -6.2 -7.1 11/07/2004 11:20:00 16.6 1.3 19.1 13 16.7 1.4 20.2 13 0.4 0 0.4 0.4 1 5 0 305 3 0 3 0 -6.9 0 -6.4 -7.1 11/07/2004 11:30:00 16 1.5 18.7 11.5 16.2 1.5 19.5 11.8 0.4 0 0.4 0.4 357 5 354 305 3 0 3 0 -6.8 0.1 -6.4 -7.1 11/07/2004 11:40:00 16 1.2 19.1 12.2 16.3 1.1 19.5 13 0.4 0 0.4 0.4 358 5 357 305 3 0 3 0 -7 0 -6.7 -7.1 11/07/2004 11:50:00 16.1 1.4 18.7 12.6 16.4 1.5 19.1 12.2 0.4 0 0.4 0.4 356 5 354 305 3 0 3 0 -6.9 0.1 -6.7 -7.1 11/07/2004 12:00:00 16.5 1.4 19.9 12.6 16.6 1.5 20.2 12.6 0.4 0 0.4 0.4 357 5 353 305 3 0 3 0 -7 0.1 -6.7 -7.1 11/07/2004 12:10:00 16.2 1.3 18.7 12.2 16.4 1.4 19.5 12.6 0.4 0 0.4 0.4 357 6 346 305 3 0 2 0 -7.1 0 -6.7 -7.3 11/07/2004 12:20:00 15.7 1.1 18.3 12.2 16 1.2 18.7 11.8 0.4 0 0.4 0.4 0 5 354 305 3 0 3 0 -7.2 0 -6.7 -7.5 11/07/2004 12:30:00 15.9 1 18.3 13.3 16.2 1 18.3 13 0.4 0 0.4 0.4 1 4 359 305 3 0 2 0 -7.4 0.1 -6.7 -7.7 11/07/2004 12:40:00 15.7 1.1 19.1 12.2 15.9 1.2 19.9 12.2 0.4 0 0.4 0.4 0 5 357 305 3 0 2 0 -7.4 0 -6.9 -7.7 11/07/2004 12:50:00 15.6 1.5 19.1 11.5 15.7 1.6 19.1 11.5 0.4 0 0.4 0.4 3 6 354 305 3 0 2 0 -7.4 0.1 -7.1 -7.7 11/07/2004 13:00:00 15.4 1.4 18.7 10.7 15.6 1.5 19.5 10.7 0.4 0 0.4 0.4 1 5 358 305 2 0 3 0 -7.3 0.1 -6.7 -7.7 11/07/2004 13:10:00 15.3 1 17.9 12.2 15.5 1.1 18.3 12.6 0.4 0 0.4 0.4 7 5 7 305 2 0 2 0 -7.4 0 -7.1 -7.7 11/07/2004 13:20:00 14.9 1.2 17.9 10.7 15.1 1.3 17.9 11.5 0.4 0 0.4 0.4 5 5 358 305 2 0 2 0 -7.2 0 -6.9 -7.5 11/07/2004 13:30:00 15.4 1.1 18.3 13 15.6 1.1 18.3 12.6 0.4 0 0.4 0.4 8 5 5 305 2 0 2 0 -7.3 0 -7.1 -7.5 11/07/2004 13:40:00 15.1 1.3 17.9 11.1 15.3 1.3 18.7 11.8 0.4 0 0.4 0.4 8 6 7 305 2 0 2 0 -7.4 0.1 -7.1 -7.7 11/07/2004 13:50:00 15.7 1.4 19.1 12.2 15.9 1.3 19.5 12.2 0.4 0 0.4 0.4 9 6 12 305 2 0 2 0 -7.2 0 -6.9 -7.3 11/07/2004 14:00:00 15 1.2 17.9 12.2 15.1 1.1 17.9 11.8 0.4 0 0.4 0.4 10 6 16 305 2 0 2 0 -7.1 0.1 -6.4 -7.3 11/07/2004 14:10:00 14.6 1.2 16.8 10.7 14.7 1.3 17.6 11.5 0.4 0 0.4 0.4 10 5 12 305 2 0 2 0 -7.1 0 -6.9 -7.5 11/07/2004 14:20:00 14.8 1.1 17.6 11.5 14.9 1.2 17.9 11.8 0.4 0 0.4 0.4 16 5 17 305 2 0 2 0 -7.2 0 -7.1 -7.5 11/07/2004 14:30:00 14.3 1.2 16.8 10.7 14.3 1.2 16.8 10.7 0.4 0 0.4 0.4 16 5 14 305 2 0 2 0 -7.3 0 -6.9 -7.5 11/07/2004 14:40:00 14.1 1 16.1 11.1 14.3 1 16.4 11.1 0.4 0 0.4 0.4 8 5 6 305 2 0 2 0 -7.2 0 -6.9 -7.5 11/07/2004 14:50:00 13.7 1 16.1 10.7 13.9 1 16.4 11.5 0.4 0 0.4 0.4 5 6 8 305 2 0 2 0 -7.1 0 -6.7 -7.3 11/07/2004 15:00:00 13.8 1 16.4 11.5 13.9 1.1 17.2 11.1 0.4 0 0.4 0.4 7 5 4 305 2 0 2 0 -7.1 0 -6.7 -7.3 11/07/2004 15:10:00 14 1.1 17.6 11.1 14.3 1.1 17.6 11.1 0.4 0 0.4 0.4 10 5 12 305 2 0 2 0 -7.1 0 -6.9 -7.3 11/07/2004 15:20:00 14 1 16.8 11.1 14.1 1.1 17.6 11.1 0.4 0 0.4 0.4 9 5 8 305 2 0 2 0 -7.1 0 -6.7 -7.3 11/07/2004 15:30:00 13.7 1.1 16.1 9.5 13.8 1.1 16.1 10.3 0.4 0 0.4 0.4 6 6 7 305 2 0 2 0 -6.9 0.1 -6.7 -7.1 11/07/2004 15:40:00 13.9 1.1 16.4 10.3 14.2 1.1 16.8 10.7 0.4 0 0.4 0.4 5 6 13 305 2 0 2 0 -6.9 0 -6.7 -7.1 11/07/2004 15:50:00 13.5 1.1 16.1 9.9 13.6 1.1 16.4 9.9 0.4 0 0.4 0.4 7 5 359 305 2 0 2 0 -6.9 0.1 -6.7 -7.1 11/07/2004 16:00:00 13.8 1 16.1 11.1 14.1 1 16.4 11.5 0.4 0 0.4 0.4 3 5 2 305 2 0 2 0 -7 0.1 -6.7 -7.3 11/07/2004 16:10:00 13.4 1.1 16.1 10.3 13.6 1.2 16.4 9.9 0.4 0 0.4 0.4 3 6 358 305 2 0 2 0 -7 0.1 -6.7 -7.1 11/07/2004 16:20:00 13.6 1.1 15.6 10.3 13.8 1.1 16.4 10.7 0.4 0 0.4 0.4 4 4 9 305 2 0 2 0 -7 0 -6.9 -7.3 11/07/2004 16:30:00 13.1 1.2 16.1 9.9 13.3 1.3 16.4 9.9 0.4 0 0.4 0.4 6 6 8 305 1 0 1 0 -7.1 0 -6.9 -7.3 11/07/2004 16:40:00 13.9 0.8 16.1 11.5 14.2 0.8 16.1 11.5 0.4 0 0.4 0.4 7 5 11 305 2 0 1 0 -7 0.1 -6.7 -7.3 11/07/2004 16:50:00 13.3 0.8 15.3 11.5 13.5 0.8 16.1 11.5 0.4 0 0.4 0.4 10 5 8 305 1 0 1 0 -7 0 -6.7 -7.3 11/07/2004 17:00:00 12.9 0.8 14.9 11.1 13.1 0.9 15.3 10.7 0.4 0 0.4 0.4 6 6 7 305 1 0 1 0 -7.1 0 -6.9 -7.3 11/07/2004 17:10:00 12.3 1.2 14.9 8 12.5 1.3 14.9 8.4 0.4 0 0.4 0.4 7 5 6 305 1 0 2 0 -6.9 0.1 -6.7 -7.1 11/07/2004 17:20:00 12.5 1 15.3 9.1 12.6 1 15.3 9.1 0.4 0 0.4 0.4 6 5 7 305 1 0 1 0 -7 0.1 -6.7 -7.3 11/07/2004 17:30:00 12.8 1.1 15.6 9.5 13 1.1 15.6 10.3 0.4 0 0.4 0.4 7 5 9 305 1 0 1 0 -7 0 -6.7 -7.1 11/07/2004 17:40:00 13.1 1 16.1 9.9 13.3 1 16.1 9.9 0.4 0 0.4 0.4 13 5 17 305 1 0 1 0 -6.9 0.1 -6.4 -7.1 11/07/2004 17:50:00 13 1.1 15.3 10.3 13.2 1.2 15.6 10.3 0.4 0 0.4 0.4 14 4 8 305 1 0 1 0 -6.8 0 -6.4 -7.1 11/07/2004 18:00:00 13.2 1 15.3 10.3 13.4 1.1 15.6 9.9 0.4 0 0.4 0.4 10 5 17 305 1 0 1 0 -6.7 0 -6.7 -6.9 11/07/2004 18:10:00 13 1.1 15.3 9.9 13.2 1.2 15.6 9.5 0.4 0 0.4 0.4 7 5 0 305 1 0 1 0 -6.6 0 -6.4 -6.9 11/07/2004 18:20:00 13.4 1 15.6 10.3 13.7 1 16.1 10.3 0.4 0 0.4 0.4 9 5 8 305 1 0 1 0 -6.6 0 -6.4 -6.9 11/07/2004 18:30:00 13.6 1.2 16.4 9.9 13.8 1.3 16.8 9.9 0.4 0 0.4 0.4 7 5 7 305 1 0 1 0 -6.6 0 -6.4 -6.9 11/07/2004 18:40:00 13.6 1.2 16.1 10.7 13.7 1.2 16.1 10.3 0.4 0 0.4 0.4 11 6 5 305 1 0 1 0 -6.7 0 -6.4 -6.9 11/07/2004 18:50:00 13.2 1.1 15.6 9.9 13.4 1.1 16.1 10.3 0.4 0 0.4 0.4 11 6 9 305 1 0 1 0 -6.5 0 -6.2 -6.7 11/07/2004 19:00:00 12.8 1 15.6 9.9 13 1.1 16.1 10.3 0.4 0 0.4 0.4 5 5 357 305 1 0 1 0 -6.6 0 -6.4 -6.9 11/07/2004 19:10:00 13.4 0.9 16.1 11.1 13.6 1 16.8 10.7 0.4 0 0.4 0.4 4 5 4 305 1 0 1 0 -6.7 0 -6.4 -6.9 11/07/2004 19:20:00 13.5 1.1 16.4 10.7 13.8 1.2 16.4 11.1 0.4 0 0.4 0.4 7 5 9 305 1 0 1 0 -6.5 0 -6.2 -6.9 11/07/2004 19:30:00 13.8 1 16.4 10.7 14.1 1.1 17.2 10.7 0.4 0 0.4 0.4 7 4 10 305 1 0 1 0 -6.7 0 -6.4 -6.9 11/07/2004 19:40:00 13.5 1 16.8 11.1 13.8 1 16.1 11.1 0.4 0 0.4 0.4 7 5 11 305 1 0 1 0 -6.6 0 -6.4 -6.9 11/07/2004 19:50:00 14.1 1 16.4 10.3 14.4 1.2 16.4 9.9 0.4 0 0.4 0.4 5 5 6 305 1 0 1 0 -6.6 0 -6.2 -6.9 11/07/2004 20:00:00 14 1 16.8 10.7 14.1 1 16.8 11.1 0.4 0 0.4 0.4 8 4 6 305 1 0 1 0 -6.7 0 -6.4 -6.9 11/07/2004 20:10:00 13.6 1.1 16.1 9.5 13.9 1.1 16.4 9.9 0.4 0 0.4 0.4 5 5 7 305 1 0 1 0 -6.6 0 -6.4 -6.7 11/07/2004 20:20:00 13.8 1.1 16.4 11.1 14 1.1 16.8 11.1 0.4 0 0.4 0.4 8 5 0 305 1 0 1 0 -6.7 0 -6.4 -6.9 11/07/2004 20:30:00 13.4 1.1 16.8 10.7 13.6 1.1 16.4 9.9 0.4 0 0.4 0.4 6 5 2 305 1 0 1 0 -6.5 0.1 -6.2 -6.9 11/07/2004 20:40:00 13.7 0.9 16.8 11.5 14 1 17.6 11.5 0.4 0 0.4 0.4 6 5 9 305 1 0 1 0 -6.4 0 -6.2 -6.7 11/07/2004 20:50:00 14.1 1.1 16.4 11.1 14.3 1.2 16.8 11.1 0.4 0 0.4 0.4 7 6 5 305 1 0 1 0 -6.3 0 -6.2 -6.7 11/07/2004 21:00:00 14.5 1 17.6 10.3 14.6 1 17.2 11.5 0.4 0 0.4 0.4 8 5 10 305 1 0 1 0 -6.3 0.1 -6 -6.4 11/07/2004 21:10:00 13.7 0.9 16.1 11.1 14 1 16.4 11.1 0.4 0 0.4 0.4 4 5 5 305 1 0 1 0 -6.4 0.1 -6.2 -6.7 11/07/2004 21:20:00 13.5 1.1 15.6 9.9 13.8 1.2 16.4 9.5 0.4 0 0.4 0.4 4 6 0 305 1 0 1 0 -6.4 0 -6.2 -6.7 11/07/2004 21:30:00 13.9 0.9 16.1 11.5 14.1 1 16.8 10.7 0.4 0 0.4 0.4 8 5 4 305 1 0 1 0 -6.4 0 -6.2 -6.7 11/07/2004 21:40:00 13.8 1 16.1 11.1 14 1.1 16.4 10.7 0.4 0 0.4 0.4 5 5 10 305 1 0 1 0 -6.4 0 -6.2 -6.7 11/07/2004 21:50:00 13.4 1.1 16.1 9.1 13.7 1.1 16.8 9.5 0.4 0 0.4 0.4 5 6 358 305 1 0 1 0 -6.4 0.1 -6.2 -6.7 11/07/2004 22:00:00 13.6 1.1 16.1 10.3 13.9 1.2 16.8 10.7 0.4 0 0.4 0.4 7 6 359 305 1 0 1 0 -6.3 0 -6 -6.4 11/07/2004 22:10:00 13.3 1.1 16.4 10.7 13.5 1.2 16.4 10.3 0.4 0 0.4 0.4 8 5 7 305 1 0 1 0 -6.3 0 -6 -6.7 11/07/2004 22:20:00 12.9 0.9 15.6 9.9 13.2 1 15.3 9.9 0.4 0 0.4 0.4 8 5 5 305 1 0 1 0 -6.2 0 -6 -6.4 11/07/2004 22:30:00 13.4 1 16.1 10.3 13.7 1 16.1 10.3 0.4 0 0.4 0.4 9 5 13 305 1 0 1 0 -6.2 0 -6 -6.4 11/07/2004 22:40:00 13.5 1 17.2 11.1 13.6 1 17.6 11.1 0.4 0 0.4 0.4 10 6 15 305 1 0 1 0 -6.2 0 -6 -6.4 11/07/2004 22:50:00 12.6 1.2 14.9 8.8 12.9 1.2 15.6 9.1 0.4 0 0.4 0.4 6 5 4 305 1 0 1 0 -6.4 0 -6.2 -6.7 11/07/2004 23:00:00 13 1.1 15.3 9.9 13.1 1.1 16.1 10.7 0.4 0 0.4 0.4 3 4 3 305 1 0 1 0 -6.3 0 -6 -6.7 11/07/2004 23:10:00 12.5 1.2 15.3 9.5 12.8 1.3 15.6 9.5 0.4 0 0.4 0.4 4 5 8 305 1 0 1 0 -6.4 0 -6.2 -6.7 11/07/2004 23:20:00 12.7 1 14.9 9.1 13 1 15.3 10.3 0.4 0 0.4 0.4 0 5 355 305 1 0 1 0 -6.5 0 -6.2 -6.7 11/07/2004 23:30:00 12.4 1 14.5 9.5 12.7 1 15.3 9.5 0.4 0 0.4 0.4 1 6 358 305 1 0 1 0 -6.4 0 -6.2 -6.7 11/07/2004 23:40:00 11.8 0.9 13.7 9.1 12 1 14.5 9.1 0.4 0 0.4 0.4 359 5 2 305 1 0 1 0 -6.4 0 -6.2 -6.7 11/07/2004 23:50:00 11.6 0.8 13.7 9.1 11.9 0.9 14.5 9.5 0.4 0 0.4 0.4 5 6 4 305 1 0 1 0 -6.4 0 -6.2 -6.7 11/08/2004 00:00:00 11.3 1 13.3 8 11.6 1 14.1 8.8 0.4 0 0.4 0.4 4 7 2 305 1 0 1 0 -6.4 0 -6 -6.7 11/08/2004 00:10:00 12 0.9 14.1 9.5 12.3 1 14.1 9.5 0.4 0 0.4 0.4 2 5 6 305 1 0 1 0 -6.3 0 -6.2 -6.4 11/08/2004 00:20:00 12.4 0.9 14.5 9.5 12.7 1 14.9 9.9 0.4 0 0.4 0.4 1 5 355 305 1 0 1 0 -6.2 0 -6 -6.4 11/08/2004 00:30:00 12.1 1 14.9 9.1 12.3 1 15.6 9.5 0.4 0 0.4 0.4 9 6 7 305 1 0 1 0 -6.1 0 -6 -6.2 11/08/2004 00:40:00 11.9 0.9 14.1 9.1 12.2 1 14.9 9.9 0.4 0 0.4 0.4 5 7 11 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 00:50:00 12.3 1 14.9 9.9 12.6 1 15.3 10.3 0.4 0 0.4 0.4 1 4 358 305 1 0 1 0 -6.2 0 -6 -6.4 11/08/2004 01:00:00 12.1 1 14.5 9.1 12.4 1.1 14.9 9.1 0.4 0 0.4 0.4 5 5 1 305 1 0 1 0 -6.2 0 -6 -6.7 11/08/2004 01:10:00 12.1 0.9 14.5 9.9 12.4 1 14.9 9.1 0.4 0 0.4 0.4 4 7 8 305 1 0 1 0 -6.1 0 -5.8 -6.4 11/08/2004 01:20:00 11.3 1.5 13.7 8 11.6 1.5 14.1 8 0.4 0 0.4 0.4 7 5 12 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 01:30:00 12.9 1 15.6 10.3 13.1 1 15.6 10.7 0.4 0 0.4 0.4 9 5 11 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 01:40:00 12 1.1 14.5 9.5 12.3 1.1 14.9 9.9 0.4 0 0.4 0.4 6 5 10 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 01:50:00 11.9 1 14.1 8.8 12.2 1.1 14.1 9.5 0.4 0 0.4 0.4 4 6 12 305 1 0 1 0 -6 0 -5.8 -6.2 11/08/2004 02:00:00 11.7 1 14.1 9.1 12 1 14.9 9.9 0.4 0 0.4 0.4 3 5 357 305 1 0 1 0 -6 0 -5.8 -6.2 11/08/2004 02:10:00 12.2 1.1 14.1 9.1 12.5 1.2 15.3 9.1 0.4 0 0.4 0.4 5 7 7 305 1 0 1 0 -5.9 0.1 -5.6 -6.2 11/08/2004 02:20:00 12.1 0.9 14.5 10.3 12.5 0.9 14.5 9.9 0.4 0 0.4 0.4 6 5 355 305 1 0 1 0 -6 0 -5.8 -6.2 11/08/2004 02:30:00 11.6 0.9 13.7 9.1 11.9 1 14.1 9.1 0.4 0 0.4 0.4 4 5 4 305 1 0 1 0 -6 0 -5.8 -6.2 11/08/2004 02:40:00 11.6 0.9 14.9 9.5 12 1 15.3 9.9 0.4 0 0.4 0.4 6 5 7 305 1 0 1 0 -6 0 -5.8 -6.2 11/08/2004 02:50:00 11.4 0.9 14.1 9.1 11.7 1 13.7 9.1 0.4 0 0.4 0.4 6 6 10 305 1 0 1 0 -6 0 -5.8 -6.2 11/08/2004 03:00:00 11.4 0.8 13.7 9.1 11.7 0.8 14.1 9.5 0.4 0 0.4 0.4 5 5 2 305 1 0 1 0 -5.9 0.1 -5.6 -6 11/08/2004 03:10:00 11.2 1 14.5 9.1 11.4 1 14.5 9.1 0.4 0 0.4 0.4 1 7 3 305 1 0 1 0 -5.9 0 -5.6 -6 11/08/2004 03:20:00 11.7 0.8 13.3 9.5 12.1 0.9 14.1 9.5 0.4 0 0.4 0.4 359 4 0 305 1 0 0 0 -6 0 -5.8 -6.2 11/08/2004 03:30:00 11.8 0.8 13.7 9.9 12.1 0.8 14.5 10.3 0.4 0 0.4 0.4 1 5 355 305 1 0 1 0 -5.9 0 -5.8 -6 11/08/2004 03:40:00 11.7 1 14.5 9.5 12 0.9 14.9 9.5 0.4 0 0.4 0.4 7 7 3 305 1 0 1 0 -5.9 0.1 -5.6 -6 11/08/2004 03:50:00 11.1 1 14.9 8.4 11.2 1.1 14.5 8 0.4 0 0.4 0.4 9 7 12 305 1 0 1 0 -5.8 0 -5.6 -6 11/08/2004 04:00:00 12.2 0.9 14.1 10.3 12.5 1 14.5 9.9 0.4 0 0.4 0.4 7 5 11 305 1 0 1 0 -5.9 0 -5.8 -6 11/08/2004 04:10:00 11.6 1 14.1 9.1 11.8 1.1 14.9 8.8 0.4 0 0.4 0.4 7 5 8 305 1 0 0 0 -5.9 0 -5.8 -6 11/08/2004 04:20:00 11.6 0.8 13.3 9.1 11.8 0.9 14.1 9.1 0.4 0 0.4 0.4 7 4 7 305 1 0 0 0 -6 0 -5.8 -6.2 11/08/2004 04:30:00 11.7 0.8 13.3 9.9 11.9 0.9 14.1 9.9 0.4 0 0.4 0.4 7 5 11 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 04:40:00 10.8 0.7 12.6 9.1 11 0.8 13 8.8 0.4 0 0.4 0.4 6 5 11 305 1 0 1 0 -6 0 -5.8 -6.2 11/08/2004 04:50:00 11 0.8 13.3 8.8 11.2 0.9 13.3 8.8 0.4 0 0.4 0.4 7 3 10 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 05:00:00 11.1 0.9 13.3 9.1 11.4 1 14.5 9.1 0.4 0 0.4 0.4 3 7 354 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 05:10:00 11.3 0.9 14.5 8 11.6 1 14.5 8.8 0.4 0 0.4 0.4 358 5 357 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 05:20:00 11.8 0.9 13.7 9.5 12.1 1 14.5 9.9 0.4 0 0.4 0.4 0 4 0 305 1 0 1 0 -6.2 0 -6 -6.2 11/08/2004 05:30:00 11 0.9 13.3 8.8 11.3 1 14.1 8.4 0.4 0 0.4 0.4 2 5 357 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 05:40:00 10.7 0.8 13 8.4 10.9 0.8 13.7 9.1 0.4 0 0.4 0.4 3 7 5 305 1 0 0 0 -6.1 0 -6 -6.2 11/08/2004 05:50:00 11.4 0.8 13.3 9.5 11.7 0.9 13.3 9.5 0.4 0 0.4 0.4 4 4 2 305 1 0 0 0 -6.2 0 -6 -6.2 11/08/2004 06:00:00 10.2 0.9 12.2 8 10.4 1 12.6 8 0.4 0 0.4 0.4 3 6 4 305 1 0 0 0 -6.1 0 -6 -6.2 11/08/2004 06:10:00 10.5 0.8 12.6 8.8 10.7 0.9 13 8.4 0.4 0 0.4 0.4 5 6 358 305 1 0 0 0 -6.2 0 -6 -6.4 11/08/2004 06:20:00 10.3 0.7 11.8 8 10.5 0.8 12.2 8 0.4 0 0.4 0.4 2 5 358 305 1 0 1 0 -6.1 0 -6 -6.2 11/08/2004 06:30:00 9.8 0.8 12.2 8 10 0.9 12.6 8 0.4 0 0.4 0.4 4 6 0 305 1 0 1 0 -6.2 0 -6 -6.4 11/08/2004 06:40:00 9.9 0.7 11.8 8.4 10.2 0.7 12.2 8.4 0.4 0 0.4 0.4 5 5 12 305 1 0 1 0 -6.2 0 -6 -6.2 11/08/2004 06:50:00 9.4 0.8 11.5 7.2 9.6 0.8 11.8 7.6 0.4 0 0.4 0.4 5 4 4 305 1 0 0 0 -6.2 0 -6 -6.4 11/08/2004 07:00:00 9.8 0.8 11.8 8 10 0.9 12.6 8 0.4 0 0.4 0.4 1 5 1 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 07:10:00 9.7 0.9 11.8 7.2 9.9 0.9 12.2 7.6 0.4 0 0.4 0.4 6 5 359 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 07:20:00 9.6 0.8 11.5 7.6 9.8 0.8 12.2 7.2 0.4 0 0.4 0.4 7 5 9 305 1 0 0 0 -6.2 0 -6 -6.4 11/08/2004 07:30:00 9 0.6 10.7 6.8 9.2 0.6 11.1 6.8 0.4 0 0.4 0.4 10 5 11 305 1 0 0 0 -6.3 0.1 -6 -6.4 11/08/2004 07:40:00 9 0.8 11.1 6.8 9.3 0.8 11.5 6.5 0.4 0 0.4 0.4 7 6 17 305 1 0 0 0 -6.2 0 -6 -6.4 11/08/2004 07:50:00 9.1 0.8 10.7 6.8 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 11 5 13 305 1 0 1 0 -6.3 0 -6 -6.4 11/08/2004 08:00:00 8.7 0.8 10.7 6.1 9 0.8 11.5 6.1 0.4 0 0.4 0.4 4 7 2 305 1 0 0 0 -6.2 0 -6.2 -6.4 11/08/2004 08:10:00 9.2 0.8 11.1 6.8 9.4 0.9 11.8 6.8 0.4 0 0.4 0.4 3 6 8 305 1 0 0 0 -6.2 0 -6 -6.4 11/08/2004 08:20:00 8.8 0.7 11.8 6.5 9 0.7 12.2 6.8 0.4 0 0.4 0.4 10 5 8 305 1 0 0 0 -6.3 0 -6.2 -6.4 11/08/2004 08:30:00 9 0.7 10.7 7.6 9.2 0.7 11.5 7.6 0.4 0 0.4 0.4 8 5 5 305 0 0 1 0 -6.3 0 -6.2 -6.7 11/08/2004 08:40:00 8.6 0.7 10.3 6.8 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 6 4 5 305 1 0 0 0 -6.4 0 -6.2 -6.4 11/08/2004 08:50:00 8.3 0.7 10.3 6.5 8.6 0.8 10.7 6.5 0.4 0 0.4 0.4 359 8 10 305 1 0 1 0 -6.3 0.1 -6 -6.4 11/08/2004 09:00:00 8.1 0.7 11.5 6.1 8.4 0.7 11.5 6.5 0.4 0 0.4 0.4 7 6 6 305 1 0 1 0 -6.4 0.1 -6 -6.7 11/08/2004 09:10:00 8 0.7 9.5 6.1 8.3 0.7 10.3 6.8 0.4 0 0.4 0.4 9 6 11 305 1 0 0 0 -6.3 0 -6.2 -6.7 11/08/2004 09:20:00 8.2 0.7 9.9 6.1 8.5 0.8 10.3 6.5 0.4 0 0.4 0.4 1 9 354 305 0 0 1 0 -6.4 0 -6.2 -6.7 11/08/2004 09:30:00 7.6 0.7 9.5 5.3 7.8 0.8 9.9 5.7 0.4 0 0.4 0.4 6 7 358 305 0 0 1 0 -6.4 0 -6.2 -6.7 11/08/2004 09:40:00 8 0.7 10.3 6.5 8.3 0.8 10.7 6.1 0.4 0 0.4 0.4 10 5 12 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/08/2004 09:50:00 8.4 0.7 9.9 6.1 8.6 0.7 10.7 6.1 0.4 0 0.4 0.4 12 7 22 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/08/2004 10:00:00 8.3 0.6 10.3 6.8 8.6 0.6 10.3 7.2 0.4 0 0.4 0.4 13 6 11 305 0 0 0 0 -6.4 0 -6.2 -6.4 11/08/2004 10:10:00 7.6 0.8 9.5 5.3 7.8 0.7 9.5 6.1 0.4 0 0.4 0.4 8 7 10 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/08/2004 10:20:00 8 0.6 9.9 6.1 8.2 0.7 10.3 6.5 0.4 0 0.4 0.4 5 7 8 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/08/2004 10:30:00 8 0.7 9.9 5.7 8.3 0.8 9.9 5.7 0.4 0 0.4 0.4 1 8 7 305 0 0 1 0 -6.4 0 -6.2 -6.7 11/08/2004 10:40:00 7.5 0.7 9.1 5.7 7.8 0.8 9.5 5.7 0.4 0 0.4 0.4 7 6 11 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/08/2004 10:50:00 7.6 0.7 9.5 6.1 7.8 0.8 10.3 6.5 0.4 0 0.4 0.4 7 6 7 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/08/2004 11:00:00 7.5 0.8 9.5 5.7 7.7 0.8 9.5 6.1 0.4 0 0.4 0.4 357 8 0 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/08/2004 11:10:00 7.5 0.6 8.8 6.1 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 359 6 4 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/08/2004 11:20:00 7 0.9 9.1 5.3 7.3 0.9 9.1 5.7 0.4 0 0.4 0.4 358 8 0 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/08/2004 11:30:00 6 0.9 8.4 3.8 6.2 0.8 8.8 4.6 0.4 0 0.4 0.4 353 7 350 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/08/2004 11:40:00 6.2 0.7 8 4.6 6.4 0.7 8.4 4.6 0.4 0 0.4 0.4 357 7 356 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/08/2004 11:50:00 6.5 0.8 8.4 4.2 6.8 0.8 8.8 4.6 0.4 0 0.4 0.4 356 7 356 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/08/2004 12:00:00 6.5 0.6 8.4 4.9 6.8 0.6 8.8 4.9 0.4 0 0.4 0.4 2 6 357 305 0 0 0 0 -6.6 0 -6.4 -6.7 11/08/2004 12:10:00 6.7 0.9 8.4 4.6 7 0.9 9.1 4.9 0.4 0 0.4 0.4 2 7 3 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/08/2004 12:20:00 6.4 0.7 8.8 4.9 6.7 0.7 8.8 4.9 0.4 0 0.4 0.4 1 7 6 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/08/2004 12:30:00 6.6 0.7 8.4 5.3 6.9 0.8 8.4 4.9 0.4 0 0.4 0.4 3 5 4 305 0 0 0 0 -6.6 0 -6.4 -6.9 11/08/2004 12:40:00 6.9 0.6 8.4 4.9 7.1 0.7 9.1 5.3 0.4 0 0.4 0.4 2 8 357 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/08/2004 12:50:00 6.6 0.6 9.1 5.3 6.9 0.6 8.8 5.7 0.4 0 0.4 0.4 5 6 11 305 0 0 0 0 -6.6 0 -6.4 -6.9 11/08/2004 13:00:00 6.5 0.7 8.4 4.9 6.8 0.7 8.8 5.3 0.4 0 0.4 0.4 359 7 348 305 0 0 0 0 -6.6 0 -6.4 -6.9 11/08/2004 13:10:00 5.7 0.7 8 4.2 6 0.7 8 4.6 0.4 0 0.4 0.4 7 7 16 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/08/2004 13:20:00 6.7 0.6 8.4 5.3 7 0.6 8.8 5.7 0.4 0 0.4 0.4 3 7 2 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/08/2004 13:30:00 6.4 0.7 8 4.6 6.7 0.7 8.4 4.9 0.4 0 0.4 0.4 4 6 2 305 0 0 0 0 -6.6 0 -6.4 -6.9 11/08/2004 13:40:00 6.5 0.7 8.8 5.3 6.8 0.8 9.1 5.3 0.4 0 0.4 0.4 1 8 7 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/08/2004 13:50:00 6.4 0.7 8.4 4.6 6.7 0.8 8.4 4.9 0.4 0 0.4 0.4 357 7 347 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/08/2004 14:00:00 6.7 0.7 8 4.9 6.9 0.7 8.4 4.9 0.4 0 0.4 0.4 6 5 5 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/08/2004 14:10:00 6.3 0.8 8.4 4.6 6.6 0.8 8.4 4.9 0.4 0 0.4 0.4 4 7 21 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/08/2004 14:20:00 5.8 0.5 7.6 4.6 6.1 0.5 7.2 4.9 0.4 0 0.4 0.4 5 7 21 305 0 0 0 0 -6.8 0 -6.7 -7.1 11/08/2004 14:30:00 6.1 0.8 8 4.2 6.4 0.8 8.4 4.6 0.4 0 0.4 0.4 8 9 5 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/08/2004 14:40:00 6.3 0.8 8.4 4.6 6.6 0.8 8.4 4.6 0.4 0 0.4 0.4 6 9 9 305 0 0 0 0 -6.8 0 -6.7 -7.1 11/08/2004 14:50:00 6.5 0.6 8 4.9 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 8 5 10 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/08/2004 15:00:00 6.2 0.8 8 4.2 6.6 0.8 8.4 4.6 0.4 0 0.4 0.4 4 7 357 305 0 0 0 0 -6.9 0 -6.7 -6.9 11/08/2004 15:10:00 6.1 0.7 8 3.8 6.4 0.7 8.4 4.2 0.4 0 0.4 0.4 359 8 356 305 0 0 0 0 -6.9 0 -6.7 -6.9 11/08/2004 15:20:00 6.2 0.6 7.6 4.2 6.5 0.6 7.6 4.9 0.4 0 0.4 0.4 358 8 352 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/08/2004 15:30:00 5.9 0.9 8.4 3.8 6.2 0.9 8.4 3.8 0.4 0 0.4 0.4 355 7 358 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/08/2004 15:40:00 6.4 0.8 8 4.2 6.7 0.7 8.8 4.6 0.4 0 0.4 0.4 356 6 356 305 0 0 0 0 -7 0 -6.9 -7.1 11/08/2004 15:50:00 6.8 0.8 9.1 5.3 7.2 0.8 9.5 5.3 0.4 0 0.4 0.4 1 7 356 305 0 0 0 0 -7 0 -6.9 -7.1 11/08/2004 16:00:00 7.2 0.7 9.5 5.7 7.5 0.7 9.9 5.7 0.4 0 0.4 0.4 359 6 353 305 0 0 0 0 -7 0 -6.7 -7.1 11/08/2004 16:10:00 6.6 0.7 8.4 4.6 6.9 0.7 8.4 4.6 0.4 0 0.4 0.4 356 7 5 305 0 0 0 0 -7 0 -6.9 -7.1 11/08/2004 16:20:00 6.8 0.6 8.8 4.9 7.2 0.7 9.1 5.3 0.4 0 0.4 0.4 356 6 357 305 0 0 0 0 -7 0 -6.7 -7.1 11/08/2004 16:30:00 7 0.7 9.5 5.3 7.3 0.7 9.9 5.7 0.4 0 0.4 0.4 355 8 1 305 0 0 0 0 -7.1 0 -6.9 -7.3 11/08/2004 16:40:00 7.4 0.8 9.1 5.3 7.8 0.8 9.5 6.1 0.4 0 0.4 0.4 356 5 359 305 0 0 0 0 -7.1 0 -6.9 -7.3 11/08/2004 16:50:00 7 0.7 9.1 5.7 7.4 0.8 9.9 5.7 0.4 0 0.4 0.4 358 6 349 305 0 0 0 0 -7.1 0 -7.1 -7.3 11/08/2004 17:00:00 6.8 0.9 8.8 4.6 7.1 0.9 9.1 4.9 0.4 0 0.4 0.4 2 5 354 305 0 0 0 0 -7.2 0 -7.1 -7.3 11/08/2004 17:10:00 6.3 0.6 8 4.9 6.6 0.6 8.8 5.3 0.4 0 0.4 0.4 359 5 4 305 0 0 0 0 -7.2 0 -7.1 -7.3 11/08/2004 17:20:00 6.6 0.7 8.4 4.9 6.9 0.7 8.8 5.3 0.4 0 0.4 0.4 3 6 8 305 0 0 0 0 -7.1 0 -6.9 -7.3 11/08/2004 17:30:00 6.8 0.7 8.8 4.6 7.1 0.7 8.8 4.9 0.4 0 0.4 0.4 3 6 1 305 0 0 0 0 -7.1 0 -6.9 -7.1 11/08/2004 17:40:00 6.3 0.7 8.4 4.6 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 355 6 7 305 0 0 0 0 -7.1 0 -6.9 -7.3 11/08/2004 17:50:00 6.5 0.6 8 4.9 6.8 0.6 8.4 4.9 0.4 0 0.4 0.4 356 7 351 305 0 0 0 0 -7 0 -6.9 -7.1 11/08/2004 18:00:00 6.6 0.6 8 5.3 7 0.7 8.8 5.7 0.4 0 0.4 0.4 354 8 348 305 0 0 0 0 -7 0 -6.9 -7.1 11/08/2004 18:10:00 6.5 0.6 8 4.6 6.8 0.7 8.4 5.3 0.4 0 0.4 0.4 353 6 352 305 0 0 0 0 -7 0 -6.9 -7.1 11/08/2004 18:20:00 6.3 0.6 8 5.3 6.7 0.6 8.4 4.9 0.4 0 0.4 0.4 357 11 350 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/08/2004 18:30:00 5.7 0.7 7.6 3.8 6.1 0.7 7.6 4.6 0.4 0 0.4 0.4 12 7 12 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/08/2004 18:40:00 5.3 0.8 7.6 3.8 5.7 0.8 8 4.2 0.4 0 0.4 0.4 357 6 1 305 0 0 0 0 -6.9 0 -6.7 -7.1 11/08/2004 18:50:00 5 0.7 6.8 3 5.4 0.7 7.2 3.8 0.4 0 0.4 0.4 5 11 12 305 0 0 0 0 -6.9 0 -6.7 -6.9 11/08/2004 19:00:00 4.9 0.7 6.5 3.4 5.1 0.7 6.8 3.4 0.4 0 0.4 0.4 7 8 0 305 0 0 0 0 -6.9 0 -6.7 -6.9 11/08/2004 19:10:00 4 0.8 5.7 2.6 4.3 0.7 5.7 2.6 0.4 0 0.4 0.4 13 7 17 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/08/2004 19:20:00 4 0.6 5.7 2.3 4.4 0.7 6.1 3 0.4 0 0.4 0.4 6 15 7 305 0 0 0 0 -6.8 0 -6.7 -6.9 11/08/2004 19:30:00 4.1 0.7 5.3 2.3 4.4 0.6 5.7 2.6 0.4 0 0.4 0.4 3 14 356 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/08/2004 19:40:00 3.8 0.5 5.3 2.3 4.1 0.5 5.7 3 0.4 0 0.4 0.4 10 7 9 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/08/2004 19:50:00 5 0.6 6.8 3.4 5.3 0.7 7.2 3.4 0.4 0 0.4 0.4 7 10 12 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/08/2004 20:00:00 4.3 0.8 6.1 2.6 4.6 0.7 6.5 3 0.4 0 0.4 0.4 13 10 22 305 0 0 0 0 -6.2 0 -6 -6.4 11/08/2004 20:10:00 4.9 0.5 6.5 3.8 5.2 0.5 6.8 4.2 0.4 0 0.4 0.4 20 9 26 305 0 0 0 0 -6.1 0 -6 -6.2 11/08/2004 20:20:00 3.9 0.4 5.3 3 4.2 0.4 5.3 3 0.4 0 0.4 0.4 24 7 31 305 0 0 0 0 -6.1 0 -6 -6.2 11/08/2004 20:30:00 4.3 0.6 5.7 3 4.5 0.6 6.1 3.4 0.4 0 0.4 0.4 24 7 27 305 0 0 0 0 -6.1 0 -6 -6.2 11/08/2004 20:40:00 4.2 0.5 5.3 3 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 21 9 23 305 0 0 1 0 -6.1 0 -6 -6.2 11/08/2004 20:50:00 5.9 0.7 8 4.2 6.2 0.8 8 4.2 0.4 0 0.4 0.4 13 5 19 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 21:00:00 6.5 0.5 7.6 5.3 6.8 0.6 8.4 5.3 0.4 0 0.4 0.4 6 6 4 305 1 0 1 0 -6.1 0 -6 -6.2 11/08/2004 21:10:00 6 0.5 7.2 4.6 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 6 5 11 305 1 0 1 0 -6.1 0 -6 -6.2 11/08/2004 21:20:00 5.5 0.6 6.8 4.2 5.9 0.6 7.2 4.6 0.4 0 0.4 0.4 3 9 353 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/08/2004 21:30:00 4.9 0.6 7.6 3.4 5.2 0.5 7.2 3.8 0.4 0 0.4 0.4 13 9 26 305 1 0 1 0 -6 0 -5.8 -6.2 11/08/2004 21:40:00 5.2 0.7 7.2 3.4 5.6 0.7 7.6 4.2 0.4 0 0.4 0.4 18 6 15 305 1 0 1 0 -5.9 0 -5.8 -6 11/08/2004 21:50:00 4.9 0.5 6.5 3.8 5.3 0.5 6.8 3.8 0.4 0 0.4 0.4 7 6 13 305 1 0 1 0 -5.9 0 -5.8 -6 11/08/2004 22:00:00 5.5 0.6 7.2 4.2 5.8 0.7 7.2 4.2 0.4 0 0.4 0.4 11 7 11 305 1 0 1 0 -5.8 0 -5.6 -6 11/08/2004 22:10:00 4.5 0.6 6.8 3 4.8 0.6 6.8 3.8 0.4 0 0.4 0.4 15 7 27 305 1 0 1 0 -5.9 0 -5.8 -6 11/08/2004 22:20:00 4.6 0.7 6.1 2.6 4.9 0.7 6.5 3.4 0.4 0 0.4 0.4 12 9 12 305 1 0 0 0 -5.9 0 -5.8 -6 11/08/2004 22:30:00 5.2 0.5 6.5 3.8 5.5 0.5 7.2 4.2 0.4 0 0.4 0.4 14 10 16 305 1 0 1 0 -6 0 -5.8 -6 11/08/2004 22:40:00 5.5 0.7 7.6 3.4 5.8 0.7 8 3.8 0.4 0 0.4 0.4 15 7 359 305 1 0 1 0 -6 0 -5.8 -6 11/08/2004 22:50:00 5.6 0.8 7.6 3.8 5.9 0.8 8 4.2 0.4 0 0.4 0.4 12 6 8 305 1 0 0 0 -6.1 0 -5.8 -6.2 11/08/2004 23:00:00 5.6 0.5 6.8 4.6 5.9 0.5 7.2 4.9 0.4 0 0.4 0.4 10 7 17 305 1 0 0 0 -6.1 0 -6 -6.2 11/08/2004 23:10:00 5.6 0.6 7.2 4.2 6 0.7 7.6 4.2 0.4 0 0.4 0.4 9 7 5 305 0 0 0 0 -6.2 0 -6 -6.2 11/08/2004 23:20:00 5.8 0.6 7.2 4.6 6.2 0.6 8 4.6 0.4 0 0.4 0.4 10 6 17 305 0 0 0 0 -6.3 0 -6 -6.4 11/08/2004 23:30:00 6.1 0.5 7.6 4.6 6.5 0.5 7.6 4.6 0.4 0 0.4 0.4 2 8 4 305 0 0 0 0 -6.4 0 -6.2 -6.4 11/08/2004 23:40:00 6 0.5 7.6 4.6 6.3 0.5 8 4.9 0.4 0 0.4 0.4 0 8 16 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/08/2004 23:50:00 5.8 0.6 7.2 4.2 6.2 0.5 7.2 4.6 0.4 0 0.4 0.4 358 8 10 305 0 0 0 0 -6.6 0 -6.4 -6.7 11/09/2004 00:00:00 5.3 0.5 6.8 3.8 5.7 0.4 6.8 4.6 0.4 0 0.4 0.4 356 6 3 305 0 0 0 0 -6.6 0 -6.2 -6.9 11/09/2004 00:10:00 5.2 0.6 6.5 3.8 5.6 0.6 6.8 4.2 0.4 0 0.4 0.4 359 5 358 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/09/2004 00:20:00 4.9 0.6 6.5 3 5.2 0.6 6.5 3 0.4 0 0.4 0.4 4 6 9 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/09/2004 00:30:00 4.9 0.5 6.1 3.4 5.2 0.6 6.5 3.4 0.4 0 0.4 0.4 3 8 17 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/09/2004 00:40:00 4.4 0.5 5.7 3 4.7 0.6 6.1 3 0.4 0 0.4 0.4 11 8 8 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/09/2004 00:50:00 4.1 0.5 5.3 3 4.5 0.5 5.3 3.4 0.4 0 0.4 0.4 13 6 12 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/09/2004 01:00:00 3.9 0.6 5.3 2.3 4.3 0.6 5.7 2.6 0.4 0 0.4 0.4 12 8 14 305 0 0 0 0 -6.6 0 -6.4 -6.9 11/09/2004 01:10:00 3.9 0.5 4.9 2.6 4.2 0.5 5.3 3 0.4 0 0.4 0.4 17 9 5 305 0 0 0 0 -6.6 0 -6.4 -6.9 11/09/2004 01:20:00 4.2 0.5 5.3 3 4.5 0.5 5.7 3 0.4 0 0.4 0.4 7 7 6 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/09/2004 01:30:00 4.3 0.5 5.7 3 4.6 0.5 5.7 3.4 0.4 0 0.4 0.4 12 6 7 305 0 0 0 0 -6.4 0 -6.2 -6.4 11/09/2004 01:40:00 4.2 0.6 5.3 3 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 13 8 18 305 0 0 0 0 -6.3 0 -6.2 -6.4 11/09/2004 01:50:00 4.5 0.5 6.1 3 4.7 0.5 6.5 3.4 0.4 0 0.4 0.4 14 7 14 305 0 0 0 0 -6.2 0 -6 -6.4 11/09/2004 02:00:00 4.4 0.4 5.3 3.4 4.6 0.4 5.7 3.4 0.4 0 0.4 0.4 27 9 15 305 0 0 0 0 -6.3 0.1 -6 -6.7 11/09/2004 02:10:00 4.2 0.6 5.3 3 4.5 0.6 5.7 3 0.4 0 0.4 0.4 19 10 15 305 0 0 0 0 -6.1 0 -6 -6.4 11/09/2004 02:20:00 4.3 0.6 5.7 3 4.6 0.6 6.1 3 0.4 0 0.4 0.4 22 8 13 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/09/2004 02:30:00 4.5 0.5 6.5 3.4 4.9 0.5 6.1 3.8 0.4 0 0.4 0.4 19 8 29 305 1 0 1 0 -6 0 -5.8 -6 11/09/2004 02:40:00 4.6 0.5 6.1 3.4 4.9 0.5 6.1 3.8 0.4 0 0.4 0.4 14 7 13 305 1 0 1 0 -5.8 0 -5.6 -6 11/09/2004 02:50:00 5.2 0.5 6.5 3.8 5.4 0.5 6.8 4.2 0.4 0 0.4 0.4 19 6 18 305 1 0 1 0 -5.7 0 -5.6 -5.8 11/09/2004 03:00:00 5.4 0.7 7.2 3.4 5.6 0.7 8 3.8 0.4 0 0.4 0.4 12 8 7 305 1 0 1 0 -5.7 0 -5.6 -5.8 11/09/2004 03:10:00 5.6 0.6 6.8 3.8 6 0.5 7.2 4.6 0.4 0 0.4 0.4 11 6 7 305 1 0 1 0 -5.6 0 -5.6 -5.8 11/09/2004 03:20:00 5.8 0.6 7.2 4.2 6.1 0.6 8 4.2 0.4 0 0.4 0.4 13 8 7 305 1 0 1 0 -5.5 0 -5.3 -5.8 11/09/2004 03:30:00 5.7 0.6 8 4.2 6.1 0.6 8 4.6 0.4 0 0.4 0.4 11 6 19 305 1 0 1 0 -5.5 0 -5.6 -5.8 11/09/2004 03:40:00 5.4 0.7 6.8 3.4 5.7 0.7 7.2 3.4 0.4 0 0.4 0.4 16 5 13 305 1 0 1 0 -5.5 0 -5.6 -5.8 11/09/2004 03:50:00 5.2 0.5 6.5 4.2 5.6 0.5 6.8 4.6 0.4 0 0.4 0.4 12 7 8 305 1 0 1 0 -5.6 0 -5.6 -5.8 11/09/2004 04:00:00 5.4 0.6 6.8 3.8 5.8 0.6 7.2 4.2 0.4 0 0.4 0.4 12 7 19 305 1 0 1 0 -5.5 0 -5.6 -5.8 11/09/2004 04:10:00 5.5 0.6 7.6 4.2 5.8 0.6 8 4.2 0.4 0 0.4 0.4 11 11 9 305 1 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 04:20:00 5.5 0.6 6.8 3.4 5.8 0.6 7.2 4.2 0.4 0 0.4 0.4 10 6 14 305 1 0 1 0 -5.6 0 -5.6 -5.8 11/09/2004 04:30:00 4.6 0.9 6.1 2.3 5 0.8 6.8 2.6 0.4 0 0.4 0.4 16 11 6 305 1 0 1 0 -5.6 0 -5.6 -5.8 11/09/2004 04:40:00 4.2 0.6 6.1 1.9 4.6 0.6 6.5 2.6 0.4 0 0.4 0.4 13 5 19 305 1 0 1 0 -5.7 0 -5.6 -5.8 11/09/2004 04:50:00 3.8 0.8 5.7 1.5 4.2 0.9 6.1 1.9 0.4 0 0.4 0.4 8 11 13 305 1 0 1 0 -5.6 0 -5.6 -5.8 11/09/2004 05:00:00 4.1 0.7 6.1 2.3 4.4 0.7 6.5 3 0.4 0 0.4 0.4 22 10 15 305 1 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 05:10:00 4.9 0.6 6.5 3.4 5.2 0.7 6.8 3.4 0.4 0 0.4 0.4 14 8 16 305 0 0 1 0 -5.5 0 -5.6 -5.8 11/09/2004 05:20:00 4.6 0.7 6.1 2.6 4.9 0.7 6.8 3.4 0.4 0 0.4 0.4 9 9 15 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 05:30:00 3.7 0.5 5.3 2.6 4 0.5 5.7 2.6 0.4 0 0.4 0.4 25 8 23 305 0 0 0 0 -5.5 0 -5.3 -5.8 11/09/2004 05:40:00 3.3 0.6 4.6 2.3 3.7 0.6 5.3 2.3 0.4 0 0.4 0.4 11 7 30 305 0 0 0 0 -5.4 0 -5.3 -5.6 11/09/2004 05:50:00 3.3 0.7 5.3 1.5 3.6 0.7 4.9 1.9 0.4 0 0.4 0.4 23 17 12 305 0 0 0 0 -5.3 0 -5.1 -5.6 11/09/2004 06:00:00 4.7 0.7 6.8 3.4 4.9 0.7 6.8 3.4 0.4 0 0.4 0.4 7 6 353 305 0 0 1 0 -5.2 0 -5.1 -5.3 11/09/2004 06:10:00 6.4 0.8 8.4 4.6 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 8 6 19 305 0 0 1 0 -5.1 0 -4.9 -5.3 11/09/2004 06:20:00 5.7 1.2 7.6 3.4 5.8 1.2 8 3.8 0.4 0 0.4 0.4 19 8 25 305 0 0 0 0 -5.2 0 -5.1 -5.6 11/09/2004 06:30:00 4.6 0.6 6.1 3 4.7 0.6 6.5 3.4 0.4 0 0.4 0.4 31 9 50 305 0 0 0 0 -5.3 0 -5.1 -5.6 11/09/2004 06:40:00 6.1 0.9 8.4 4.2 6.2 0.9 8 4.6 0.4 0 0.4 0.4 35 9 23 305 0 0 0 0 -5.1 0 -4.9 -5.3 11/09/2004 06:50:00 6.6 0.7 8.8 4.9 6.7 0.7 8.8 4.6 0.4 0 0.4 0.4 30 8 38 305 0 0 0 0 -5 0 -4.9 -5.1 11/09/2004 07:00:00 6.6 0.7 8.4 4.9 6.7 0.7 8.4 4.6 0.4 0 0.4 0.4 37 7 46 305 0 0 0 0 -5 0 -4.7 -5.1 11/09/2004 07:10:00 7.5 1.2 9.5 4.9 7.6 1.3 9.5 4.9 0.4 0 0.4 0.4 26 5 23 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/09/2004 07:20:00 8.1 0.7 9.5 6.5 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 15 6 18 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/09/2004 07:30:00 7.9 0.8 9.5 5.7 8 0.9 9.9 5.7 0.4 0 0.4 0.4 21 6 14 305 0 0 0 0 -5 0 -4.7 -5.1 11/09/2004 07:40:00 7.5 0.6 9.1 5.7 7.7 0.6 9.5 6.1 0.4 0 0.4 0.4 19 7 24 305 0 0 0 0 -5.1 0 -4.9 -5.3 11/09/2004 07:50:00 7.1 1 9.1 4.6 7.3 1 9.5 4.6 0.4 0 0.4 0.4 23 6 23 305 0 0 0 0 -5.2 0 -5.1 -5.6 11/09/2004 08:00:00 7.8 0.8 9.5 5.7 7.9 0.8 9.5 5.7 0.4 0 0.4 0.4 23 6 31 305 0 0 0 0 -5.2 0.1 -4.9 -5.6 11/09/2004 08:10:00 7.4 0.8 8.8 5.3 7.6 0.8 9.1 5.7 0.4 0 0.4 0.4 21 8 8 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/09/2004 08:20:00 7.4 0.7 9.1 5.7 7.6 0.7 9.5 6.1 0.4 0 0.4 0.4 25 6 28 305 0 0 0 0 -5.5 0 -5.1 -5.6 11/09/2004 08:30:00 7.1 0.8 9.5 5.3 7.3 0.9 9.9 5.3 0.4 0 0.4 0.4 30 7 33 305 0 0 0 0 -5.5 0 -5.1 -5.6 11/09/2004 08:40:00 7.1 0.8 10.3 5.3 7.3 0.8 10.3 5.7 0.4 0 0.4 0.4 33 9 41 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/09/2004 08:50:00 7.1 0.6 8.8 5.3 7.3 0.7 8.8 5.7 0.4 0 0.4 0.4 34 8 42 305 0 0 0 0 -5.5 0 -5.6 -5.6 11/09/2004 09:00:00 7.2 0.6 8.8 5.7 7.3 0.6 9.1 5.7 0.4 0 0.4 0.4 37 7 34 305 0 0 0 0 -5.6 0 -5.3 -5.8 11/09/2004 09:10:00 7.2 0.8 8.8 5.3 7.4 0.8 9.1 5.7 0.4 0 0.4 0.4 35 9 33 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 09:20:00 7.3 0.6 8.8 5.7 7.4 0.6 9.1 6.1 0.4 0 0.4 0.4 29 6 27 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 09:30:00 7.2 0.8 9.1 5.7 7.4 0.8 9.5 5.7 0.4 0 0.4 0.4 32 6 31 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/09/2004 09:40:00 7.1 0.8 9.1 4.9 7.3 0.8 9.1 5.7 0.4 0 0.4 0.4 30 8 21 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/09/2004 09:50:00 7.5 0.8 9.1 5.3 7.5 0.7 9.5 5.7 0.4 0 0.4 0.4 27 4 29 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/09/2004 10:00:00 7.2 0.6 9.1 6.1 7.4 0.6 9.1 6.1 0.4 0 0.4 0.4 35 9 46 305 0 0 0 0 -5.8 0 -5.6 -6 11/09/2004 10:10:00 7.5 0.7 9.1 6.1 7.7 0.7 9.5 6.1 0.4 0 0.4 0.4 34 5 28 305 0 0 0 0 -5.8 0 -5.6 -6 11/09/2004 10:20:00 7.5 0.8 9.5 6.1 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 37 5 36 305 0 0 0 0 -5.8 0 -5.6 -5.8 11/09/2004 10:30:00 7 0.7 8.8 5.3 7.1 0.7 8.8 5.3 0.4 0 0.4 0.4 35 6 37 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 10:40:00 7.6 0.7 9.5 6.1 7.7 0.6 9.5 6.5 0.4 0 0.4 0.4 35 7 40 305 0 0 0 0 -5.8 0 -5.6 -5.8 11/09/2004 10:50:00 7.4 0.7 8.8 5.7 7.5 0.8 9.1 5.7 0.4 0 0.4 0.4 43 6 41 305 0 0 0 0 -5.8 0 -5.8 -6 11/09/2004 11:00:00 7.4 0.8 9.5 5.3 7.6 0.8 9.9 5.7 0.4 0 0.4 0.4 39 6 36 305 0 0 0 0 -5.8 0 -5.8 -6 11/09/2004 11:10:00 7.1 0.8 9.5 5.3 7.2 0.8 9.1 4.9 0.4 0 0.4 0.4 31 5 29 305 0 0 0 0 -5.8 0 -5.8 -6 11/09/2004 11:20:00 7.2 0.6 8.8 5.7 7.4 0.6 9.1 6.1 0.4 0 0.4 0.4 30 5 25 305 0 0 0 0 -5.8 0 -5.6 -6 11/09/2004 11:30:00 7.3 0.6 8.8 5.7 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 37 7 32 305 0 0 0 0 -5.8 0 -5.6 -6 11/09/2004 11:40:00 7.5 0.8 9.1 5.3 7.6 0.7 9.1 5.7 0.4 0 0.4 0.4 28 5 21 305 0 0 0 0 -5.8 0 -5.6 -6 11/09/2004 11:50:00 7 0.8 8.8 4.9 7.2 0.8 9.1 4.9 0.4 0 0.4 0.4 31 7 36 305 0 0 0 0 -5.8 0 -5.8 -6 11/09/2004 12:00:00 7.5 0.6 9.5 5.3 7.7 0.7 9.5 5.7 0.4 0 0.4 0.4 24 5 25 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 12:10:00 7.4 0.5 8.8 6.1 7.6 0.6 8.8 6.1 0.4 0 0.4 0.4 28 8 40 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 12:20:00 7.9 0.8 9.9 6.5 8.1 0.8 10.3 6.5 0.4 0 0.4 0.4 30 7 28 305 0 0 0 0 -5.8 0 -5.6 -6 11/09/2004 12:30:00 7.6 1 9.5 5.7 7.8 1 9.9 5.7 0.4 0 0.4 0.4 27 6 32 305 0 0 0 0 -5.8 0 -5.6 -6 11/09/2004 12:40:00 7.7 0.9 9.5 5.7 7.9 0.8 9.5 6.1 0.4 0 0.4 0.4 28 8 25 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 12:50:00 7.9 0.7 9.5 6.1 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 27 6 21 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 13:00:00 7.8 0.8 10.7 6.5 7.9 0.9 11.1 6.1 0.4 0 0.4 0.4 26 8 19 305 0 0 0 0 -5.6 0 -5.3 -5.8 11/09/2004 13:10:00 8.4 0.8 10.3 6.1 8.6 0.8 10.3 6.1 0.4 0 0.4 0.4 22 5 17 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 13:20:00 8.1 0.6 9.9 6.5 8.2 0.7 10.3 6.1 0.4 0 0.4 0.4 21 9 38 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 13:30:00 8.1 0.9 10.7 5.7 8.2 0.9 11.1 5.7 0.4 0 0.4 0.4 23 6 25 305 0 0 0 0 -5.7 0.1 -5.6 -6 11/09/2004 13:40:00 7.7 1 9.5 4.9 7.8 1 9.9 5.3 0.4 0 0.4 0.4 23 6 24 305 0 0 0 0 -5.5 0 -5.3 -5.8 11/09/2004 13:50:00 7.7 0.8 9.9 5.7 7.9 0.9 9.9 5.7 0.4 0 0.4 0.4 24 7 17 305 0 0 0 0 -5.5 0 -5.3 -5.8 11/09/2004 14:00:00 7.8 0.6 9.1 6.1 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 29 6 27 305 0 0 0 0 -5.6 0 -5.3 -5.8 11/09/2004 14:10:00 7.7 0.5 9.1 6.1 7.9 0.6 9.5 6.1 0.4 0 0.4 0.4 21 7 16 305 0 0 0 0 -5.6 0.1 -5.3 -5.8 11/09/2004 14:20:00 7.9 0.8 9.5 5.7 8 0.8 9.9 6.1 0.4 0 0.4 0.4 26 6 28 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/09/2004 14:30:00 7.6 0.6 9.9 6.1 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 24 9 22 305 0 0 0 0 -5.6 0.1 -5.1 -5.8 11/09/2004 14:40:00 8.2 0.6 9.9 6.5 8.3 0.7 10.3 6.8 0.4 0 0.4 0.4 27 5 32 305 0 0 0 0 -5.6 0.1 -5.1 -5.8 11/09/2004 14:50:00 8 0.6 9.1 6.1 8.1 0.6 9.5 6.1 0.4 0 0.4 0.4 27 8 21 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/09/2004 15:00:00 7.7 1 10.7 5.7 7.9 1 10.7 6.1 0.4 0 0.4 0.4 23 5 22 305 0 0 0 0 -5.6 0 -5.3 -5.8 11/09/2004 15:10:00 7.5 0.9 9.9 5.7 7.7 0.9 9.9 5.7 0.4 0 0.4 0.4 24 6 28 305 0 0 0 0 -5.7 0.2 -5.3 -6 11/09/2004 15:20:00 7.5 0.8 9.5 5.7 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 30 6 35 305 0 0 0 0 -5.8 0 -5.6 -6 11/09/2004 15:30:00 7.1 0.8 9.1 5.3 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 30 5 31 305 0 0 0 0 -5.7 0 -5.6 -6 11/09/2004 15:40:00 7.7 0.7 9.5 6.1 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 23 5 33 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/09/2004 15:50:00 7.5 0.7 9.5 6.1 7.7 0.8 9.5 6.1 0.4 0 0.4 0.4 27 7 30 305 0 0 0 0 -5.8 0 -5.6 -6 11/09/2004 16:00:00 7.6 0.7 9.1 5.7 7.9 0.8 9.5 6.1 0.4 0 0.4 0.4 21 6 17 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/09/2004 16:10:00 8 0.6 9.5 6.5 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 19 8 25 305 0 0 0 0 -5.7 0 -5.6 -6 11/09/2004 16:20:00 7.9 0.8 10.3 6.1 8.2 0.9 10.3 6.5 0.4 0 0.4 0.4 16 4 18 305 0 0 0 0 -5.8 0 -5.6 -6 11/09/2004 16:30:00 7.9 0.8 9.9 6.1 8.1 0.9 10.7 6.1 0.4 0 0.4 0.4 22 7 27 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 16:40:00 8.2 0.7 9.9 6.5 8.4 0.8 9.9 6.5 0.4 0 0.4 0.4 16 6 19 305 0 0 0 0 -5.8 0.1 -5.6 -6 11/09/2004 16:50:00 8 0.7 9.9 6.5 8.2 0.7 10.3 6.5 0.4 0 0.4 0.4 20 6 18 305 0 0 0 0 -5.9 0 -5.8 -6.2 11/09/2004 17:00:00 7.8 0.6 9.1 6.1 8 0.6 9.5 6.5 0.4 0 0.4 0.4 18 4 11 305 0 0 0 0 -6 0 -5.8 -6 11/09/2004 17:10:00 7.3 0.6 9.1 5.3 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 19 6 23 305 0 0 0 0 -6 0 -5.8 -6 11/09/2004 17:20:00 7.8 0.8 9.9 6.1 8 0.8 9.9 5.7 0.4 0 0.4 0.4 23 7 31 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/09/2004 17:30:00 7.6 0.9 9.5 4.9 7.9 0.9 9.9 4.9 0.4 0 0.4 0.4 17 8 11 305 0 0 0 0 -6 0 -5.8 -6.2 11/09/2004 17:40:00 7.9 0.6 9.1 6.1 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 22 9 27 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/09/2004 17:50:00 7.9 0.8 9.9 6.1 8 0.8 10.3 6.5 0.4 0 0.4 0.4 26 4 33 305 0 0 0 0 -6.1 0 -6 -6.2 11/09/2004 18:00:00 7.6 0.8 9.1 5.3 7.9 0.8 9.5 5.7 0.4 0 0.4 0.4 23 8 32 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/09/2004 18:10:00 7.7 0.7 9.5 6.1 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 20 7 27 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/09/2004 18:20:00 8 0.8 11.1 6.5 8.2 0.8 11.5 6.5 0.4 0 0.4 0.4 24 8 8 305 0 0 0 0 -6.1 0 -6 -6.2 11/09/2004 18:30:00 7.9 0.8 9.9 6.1 8 0.8 9.9 5.7 0.4 0 0.4 0.4 26 6 30 305 0 0 0 0 -6 0 -5.8 -6.2 11/09/2004 18:40:00 8.2 0.7 9.9 6.5 8.4 0.7 10.3 6.8 0.4 0 0.4 0.4 25 7 29 305 0 0 0 0 -6 0 -5.8 -6.2 11/09/2004 18:50:00 7.7 0.8 9.5 5.7 7.9 0.9 9.9 5.7 0.4 0 0.4 0.4 22 6 19 305 0 0 0 0 -6.1 0 -6 -6.2 11/09/2004 19:00:00 7.4 0.8 10.7 5.3 7.6 0.8 10.7 6.1 0.4 0 0.4 0.4 24 7 21 305 0 0 0 0 -6 0 -5.8 -6.2 11/09/2004 19:10:00 7.8 0.7 9.5 6.1 8 0.8 10.3 6.1 0.4 0 0.4 0.4 22 4 23 305 0 0 0 0 -6 0 -5.8 -6.2 11/09/2004 19:20:00 7.8 0.7 10.7 6.5 7.9 0.7 9.9 6.5 0.4 0 0.4 0.4 22 10 32 305 0 0 0 0 -6 0 -5.8 -6.2 11/09/2004 19:30:00 7.7 0.9 9.9 5.7 7.9 0.9 9.9 4.6 0.4 0 0.4 0.4 14 5 15 305 0 0 0 0 -6 0 -5.8 -6 11/09/2004 19:40:00 7.5 0.9 9.9 5.3 7.7 0.9 10.3 5.7 0.4 0 0.4 0.4 24 7 20 305 0 0 0 0 -6 0 -5.8 -6 11/09/2004 19:50:00 7.2 0.8 8.8 4.9 7.4 0.8 9.5 5.3 0.4 0 0.4 0.4 21 5 34 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 20:00:00 7.1 0.6 8.8 5.3 7.4 0.6 9.1 5.7 0.4 0 0.4 0.4 25 7 26 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 20:10:00 7.5 0.7 9.1 5.7 7.7 0.8 9.9 6.1 0.4 0 0.4 0.4 17 5 21 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 20:20:00 7.5 0.8 9.5 5.3 7.8 0.8 9.9 6.1 0.4 0 0.4 0.4 16 7 13 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 20:30:00 7 0.8 9.1 5.7 7.3 0.8 9.5 5.3 0.4 0 0.4 0.4 25 7 37 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 20:40:00 7.6 0.8 9.5 5.7 7.8 0.8 10.3 5.7 0.4 0 0.4 0.4 14 6 12 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 20:50:00 7.7 0.7 9.1 5.7 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 18 8 15 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 21:00:00 7.7 0.6 9.1 6.1 7.9 0.6 9.5 6.1 0.4 0 0.4 0.4 17 5 19 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 21:10:00 7.1 0.7 8.8 5.3 7.4 0.7 9.1 5.3 0.4 0 0.4 0.4 19 8 11 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 21:20:00 7.9 0.6 9.5 6.1 8.1 0.6 9.9 6.5 0.4 0 0.4 0.4 17 7 11 305 0 0 0 0 -5.9 0 -5.8 -6 11/09/2004 21:30:00 7.7 0.7 9.5 6.1 8 0.7 9.9 6.1 0.4 0 0.4 0.4 20 6 12 305 0 0 0 0 -5.8 0 -5.6 -6 11/09/2004 21:40:00 7.5 0.8 9.1 5.7 7.7 0.8 9.5 6.1 0.4 0 0.4 0.4 24 6 13 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/09/2004 21:50:00 7.4 0.7 9.5 5.7 7.6 0.7 9.5 6.1 0.4 0 0.4 0.4 25 6 29 305 0 0 0 0 -5.8 0 -5.6 -5.8 11/09/2004 22:00:00 7.2 0.6 8.8 5.7 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 20 7 19 305 0 0 0 0 -5.7 0 -5.6 -6 11/09/2004 22:10:00 7.5 0.8 10.3 5.7 7.7 0.8 9.9 6.1 0.4 0 0.4 0.4 24 7 21 305 0 0 0 0 -5.7 0 -5.6 -6 11/09/2004 22:20:00 7.8 0.8 9.5 5.7 8 0.8 9.9 6.1 0.4 0 0.4 0.4 23 5 25 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 22:30:00 7.6 0.6 9.9 6.1 7.9 0.6 9.9 6.5 0.4 0 0.4 0.4 22 9 19 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 22:40:00 7.7 0.7 9.5 5.7 7.9 0.8 9.5 6.1 0.4 0 0.4 0.4 24 4 29 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/09/2004 22:50:00 7.8 0.9 9.9 4.9 8 0.9 10.3 5.7 0.4 0 0.4 0.4 20 6 19 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/09/2004 23:00:00 7.7 0.7 9.1 5.7 7.9 0.8 9.5 6.1 0.4 0 0.4 0.4 23 6 22 305 0 0 0 0 -5.6 0 -5.3 -5.8 11/09/2004 23:10:00 7.3 0.6 8.8 5.7 7.5 0.7 9.5 5.7 0.4 0 0.4 0.4 27 5 22 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 23:20:00 7.9 0.7 9.9 6.5 8.1 0.7 9.9 6.5 0.4 0 0.4 0.4 17 6 20 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 23:30:00 8 0.7 9.5 6.1 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 20 5 27 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/09/2004 23:40:00 8.1 0.8 9.9 6.1 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 19 6 17 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/09/2004 23:50:00 8.1 0.9 9.9 6.1 8.2 1 10.7 6.1 0.4 0 0.4 0.4 23 7 19 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/10/2004 00:00:00 7.8 0.8 10.3 6.1 8 0.8 9.9 6.5 0.4 0 0.4 0.4 17 7 25 305 0 0 0 0 -5.6 0 -5.3 -5.8 11/10/2004 00:10:00 8.4 0.8 10.3 6.5 8.7 0.8 10.7 6.1 0.4 0 0.4 0.4 12 5 16 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/10/2004 00:20:00 8.3 0.7 10.7 6.5 8.5 0.7 10.7 7.2 0.4 0 0.4 0.4 18 6 22 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/10/2004 00:30:00 7.9 0.7 9.9 6.5 8.2 0.7 9.9 6.8 0.4 0 0.4 0.4 18 6 14 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/10/2004 00:40:00 7.9 0.9 9.9 5.3 8.2 0.9 10.7 5.7 0.4 0 0.4 0.4 13 6 16 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/10/2004 00:50:00 8.2 0.9 10.3 6.1 8.4 1 10.3 5.7 0.4 0 0.4 0.4 22 7 19 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/10/2004 01:00:00 8.2 0.7 10.3 6.5 8.4 0.7 9.9 6.8 0.4 0 0.4 0.4 21 6 17 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/10/2004 01:10:00 8.2 0.7 9.9 6.1 8.5 0.7 10.7 6.8 0.4 0 0.4 0.4 14 6 15 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/10/2004 01:20:00 8.5 0.8 10.3 6.5 8.7 0.8 10.7 6.5 0.4 0 0.4 0.4 23 5 22 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/10/2004 01:30:00 8.6 1 12.2 6.5 8.9 1 12.2 6.8 0.4 0 0.4 0.4 17 6 22 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/10/2004 01:40:00 8.8 0.9 10.7 6.8 9 0.9 11.5 6.8 0.4 0 0.4 0.4 19 5 13 305 0 0 0 0 -5.5 0 -5.6 -5.8 11/10/2004 01:50:00 9 0.7 10.7 6.8 9.3 0.7 11.1 6.8 0.4 0 0.4 0.4 18 6 20 305 0 0 0 0 -5.5 0 -5.6 -5.8 11/10/2004 02:00:00 9.1 0.6 10.7 7.6 9.3 0.6 11.1 7.6 0.4 0 0.4 0.4 24 5 21 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/10/2004 02:10:00 9.1 0.8 11.8 7.2 9.3 0.8 12.6 7.6 0.4 0 0.4 0.4 17 7 20 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/10/2004 02:20:00 8.9 0.7 11.1 7.6 9.1 0.7 11.1 7.6 0.4 0 0.4 0.4 21 7 18 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/10/2004 02:30:00 9.2 0.7 11.1 7.2 9.4 0.7 11.5 7.6 0.4 0 0.4 0.4 19 7 25 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/10/2004 02:40:00 9.3 0.7 11.5 7.2 9.5 0.7 11.8 7.6 0.4 0 0.4 0.4 19 7 30 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/10/2004 02:50:00 9 0.7 11.5 7.2 9.3 0.8 11.5 7.2 0.4 0 0.4 0.4 14 6 16 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/10/2004 03:00:00 9.6 0.7 11.1 7.2 9.8 0.8 11.5 7.6 0.4 0 0.4 0.4 13 5 13 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/10/2004 03:10:00 9.2 0.7 11.1 7.6 9.4 0.7 11.1 7.6 0.4 0 0.4 0.4 16 5 11 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/10/2004 03:20:00 9.3 0.7 11.5 7.6 9.5 0.8 11.8 7.6 0.4 0 0.4 0.4 12 4 11 305 0 0 0 0 -5.3 0 -5.1 -5.6 11/10/2004 03:30:00 10.1 0.7 12.2 8 10.3 0.7 11.8 8.4 0.4 0 0.4 0.4 15 3 18 305 0 0 0 0 -5.3 0 -5.1 -5.6 11/10/2004 03:40:00 10.1 0.6 11.5 8 10.3 0.7 11.8 8.4 0.4 0 0.4 0.4 17 7 13 305 0 0 0 0 -5.3 0 -5.1 -5.6 11/10/2004 03:50:00 10.1 0.8 12.2 8 10.3 0.9 12.2 8.4 0.4 0 0.4 0.4 18 5 11 305 0 0 0 0 -5.2 0 -5.1 -5.6 11/10/2004 04:00:00 10 1 12.6 8 10.1 1 13 7.6 0.4 0 0.4 0.4 21 5 16 305 0 0 0 0 -5.2 0 -5.1 -5.3 11/10/2004 04:10:00 10.2 0.8 12.2 7.6 10.3 0.9 12.2 7.6 0.4 0 0.4 0.4 20 5 23 305 0 0 0 0 -5.1 0 -4.9 -5.3 11/10/2004 04:20:00 9.6 1 12.2 7.6 9.7 1 12.2 7.6 0.4 0 0.4 0.4 22 6 25 305 0 0 0 0 -5 0 -4.9 -5.1 11/10/2004 04:30:00 10 0.8 11.8 7.6 10.2 0.8 11.8 8 0.4 0 0.4 0.4 22 8 29 305 0 0 0 0 -5 0 -4.9 -5.1 11/10/2004 04:40:00 9.9 0.7 12.2 7.2 10 0.7 12.6 7.6 0.4 0 0.4 0.4 20 7 17 305 0 0 0 0 -4.9 0 -4.7 -5.1 11/10/2004 04:50:00 10.3 1 12.6 8 10.4 1 13 7.6 0.4 0 0.4 0.4 21 7 23 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/10/2004 05:00:00 9.9 1.1 12.6 7.2 10.1 1.2 13 7.6 0.4 0 0.4 0.4 18 6 14 305 0 0 0 0 -4.9 0 -4.5 -4.9 11/10/2004 05:10:00 10.2 1 13 8 10.4 1.1 13 8 0.4 0 0.4 0.4 17 6 11 305 0 0 0 0 -4.7 0 -4.5 -4.9 11/10/2004 05:20:00 11 1.2 13.7 8.4 11.2 1.2 14.1 8.4 0.4 0 0.4 0.4 16 5 17 305 0 0 0 0 -4.6 0 -4.5 -4.7 11/10/2004 05:30:00 11.4 0.9 13.3 8.8 11.6 0.9 13.7 8.8 0.4 0 0.4 0.4 18 4 17 305 0 0 0 0 -4.7 0.1 -4.5 -4.9 11/10/2004 05:40:00 11.1 0.9 13.3 9.1 11.3 0.9 13.7 9.1 0.4 0 0.4 0.4 16 5 22 305 0 0 0 0 -4.8 0 -4.7 -4.9 11/10/2004 05:50:00 11.4 1 13.7 9.5 11.6 1 14.5 9.1 0.4 0 0.4 0.4 22 7 25 305 0 0 0 0 -4.7 0 -4.5 -4.9 11/10/2004 06:00:00 10.9 0.7 12.6 9.1 11.1 0.7 13 9.1 0.4 0 0.4 0.4 16 6 27 305 0 0 0 0 -4.7 0 -4.5 -4.7 11/10/2004 06:10:00 11.6 1 13.7 9.1 11.8 1 14.5 9.1 0.4 0 0.4 0.4 20 7 13 305 0 0 0 0 -4.5 0 -4.5 -4.7 11/10/2004 06:20:00 11.7 1 14.1 9.1 11.7 1.1 14.5 8.8 0.4 0 0.4 0.4 28 4 29 305 0 0 0 0 -4.5 0 -4.5 -4.7 11/10/2004 06:30:00 12 0.9 14.5 9.9 12.2 1 14.9 9.9 0.4 0 0.4 0.4 17 5 14 305 0 0 0 0 -4.7 0 -4.5 -4.7 11/10/2004 06:40:00 11.9 1.1 14.9 9.5 12.1 1.1 15.3 9.5 0.4 0 0.4 0.4 22 6 13 305 0 0 0 0 -4.7 0 -4.5 -4.7 11/10/2004 06:50:00 11.7 1 13.7 8.8 11.8 1 14.9 8.8 0.4 0 0.4 0.4 22 5 22 305 0 0 0 0 -4.6 0 -4.5 -4.7 11/10/2004 07:00:00 12 1.1 14.5 9.9 12.2 1.1 14.9 9.1 0.4 0 0.4 0.4 20 6 17 305 0 0 0 0 -4.5 0 -4.5 -4.7 11/10/2004 07:10:00 11.8 1.1 15.3 9.1 11.9 1.1 15.3 9.1 0.4 0 0.4 0.4 22 5 16 305 0 0 0 0 -4.5 0 -4.5 -4.7 11/10/2004 07:20:00 12.1 1.1 14.5 9.1 12.1 1.2 14.9 9.5 0.4 0 0.4 0.4 29 5 29 305 0 0 0 0 -4.6 0 -4.5 -4.7 11/10/2004 07:30:00 12.5 0.9 14.9 10.3 12.7 0.9 15.3 9.5 0.4 0 0.4 0.4 18 4 14 305 0 0 0 0 -4.6 0 -4.5 -4.7 11/10/2004 07:40:00 12.2 1.3 15.3 9.5 12.3 1.2 15.6 9.5 0.4 0 0.4 0.4 27 8 31 305 0 0 0 0 -4.6 0 -4.5 -4.7 11/10/2004 07:50:00 12.7 1 15.3 9.9 12.8 1.1 15.3 10.3 0.4 0 0.4 0.4 25 7 18 305 0 0 0 0 -4.7 0 -4.5 -4.7 11/10/2004 08:00:00 12.8 1 15.3 9.9 12.9 1 15.3 9.1 0.4 0 0.4 0.4 34 5 34 305 0 0 0 0 -4.7 0 -4.2 -4.7 11/10/2004 08:10:00 12.5 0.9 14.5 10.3 12.6 1 14.9 9.9 0.4 0 0.4 0.4 27 5 31 305 0 0 0 0 -4.7 0 -4.2 -4.9 11/10/2004 08:20:00 13 1.1 14.9 9.5 13 1.2 15.3 9.9 0.4 0 0.4 0.4 26 6 27 305 0 0 0 0 -4.7 0 -4.2 -4.9 11/10/2004 08:30:00 13 1.1 15.6 10.3 13.1 1.2 16.4 10.3 0.4 0 0.4 0.4 25 5 25 305 0 0 0 0 -4.8 0.1 -4.5 -4.9 11/10/2004 08:40:00 13.1 1.1 16.1 10.7 13.1 1.1 16.4 10.3 0.4 0 0.4 0.4 25 6 39 305 0 0 0 0 -4.8 0 -4.7 -4.9 11/10/2004 08:50:00 13.2 1.1 15.6 10.7 13.3 1.1 15.6 11.1 0.4 0 0.4 0.4 28 5 31 305 0 0 0 0 -4.8 0.1 -4.5 -4.9 11/10/2004 09:00:00 13.1 1.2 16.1 10.3 13.2 1.2 16.1 10.7 0.4 0 0.4 0.4 23 8 27 305 0 0 0 0 -4.8 0 -4.7 -4.9 11/10/2004 09:10:00 12.8 1.2 15.6 9.5 13 1.3 16.1 9.9 0.4 0 0.4 0.4 21 6 17 305 0 0 0 0 -4.8 0.1 -4.5 -4.9 11/10/2004 09:20:00 13.5 1.4 16.8 11.1 13.7 1.3 16.8 10.7 0.4 0 0.4 0.4 29 4 28 305 0 0 0 0 -4.9 0 -4.5 -4.9 11/10/2004 09:30:00 13.1 1.1 15.6 10.7 13.2 1.1 15.6 10.7 0.4 0 0.4 0.4 26 5 26 305 0 0 0 0 -4.9 0 -4.7 -5.1 11/10/2004 09:40:00 13.2 1 14.9 9.9 13.3 1 15.6 10.3 0.4 0 0.4 0.4 25 6 30 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/10/2004 09:50:00 12.7 1.5 16.4 9.1 12.7 1.4 16.4 8.8 0.4 0 0.4 0.4 28 6 28 305 0 0 0 0 -4.9 0 -4.7 -5.1 11/10/2004 10:00:00 13.4 1.2 16.1 10.3 13.5 1.3 16.4 10.3 0.4 0 0.4 0.4 30 5 35 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 10:10:00 13.4 1 16.4 10.3 13.4 1 16.1 10.7 0.4 0 0.4 0.4 31 8 25 305 0 0 0 0 -5 0 -4.9 -5.1 11/10/2004 10:20:00 12.9 1.1 15.6 10.3 13 1.2 15.6 9.9 0.4 0 0.4 0.4 25 8 30 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 10:30:00 13.2 1 16.1 10.3 13.4 1.1 16.1 10.7 0.4 0 0.4 0.4 23 4 24 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 10:40:00 13.8 1 16.4 11.5 13.8 1.1 16.4 11.1 0.4 0 0.4 0.4 29 5 22 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 10:50:00 13.5 1.1 15.6 10.7 13.5 1.1 16.1 10.7 0.4 0 0.4 0.4 25 6 27 305 0 0 0 0 -5.1 0 -4.7 -5.3 11/10/2004 11:00:00 13.3 1.2 16.1 9.9 13.4 1.2 16.8 9.5 0.4 0 0.4 0.4 26 3 20 305 0 0 0 0 -5.1 0 -4.9 -5.1 11/10/2004 11:10:00 13.7 1.1 16.1 11.1 13.7 1.1 16.1 11.1 0.4 0 0.4 0.4 28 4 33 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 11:20:00 13.9 1 16.1 10.3 14.1 1 16.1 10.3 0.4 0 0.4 0.4 24 4 20 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 11:30:00 13.5 1 15.6 10.7 13.6 1 16.4 10.7 0.4 0 0.4 0.4 24 5 21 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 11:40:00 13.7 1 16.1 11.1 13.8 1.1 16.4 11.5 0.4 0 0.4 0.4 23 5 27 305 0 0 0 0 -5 0 -4.9 -5.1 11/10/2004 11:50:00 14.1 0.8 16.8 11.8 14.3 0.9 16.1 11.8 0.4 0 0.4 0.4 20 6 19 305 0 0 0 0 -5 0 -4.9 -5.1 11/10/2004 12:00:00 14 0.9 16.1 11.5 14.1 1 16.4 11.1 0.4 0 0.4 0.4 20 4 22 305 0 0 0 0 -5 0 -4.9 -5.1 11/10/2004 12:10:00 13.8 0.9 16.1 11.1 13.8 1 16.1 10.7 0.4 0 0.4 0.4 20 6 17 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 12:20:00 14.3 0.9 17.2 12.6 14.4 1 17.6 11.8 0.4 0 0.4 0.4 19 6 13 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 12:30:00 13.6 1.1 16.1 10.7 13.8 1.1 16.4 11.1 0.4 0 0.4 0.4 21 5 18 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 12:40:00 13.7 1.1 15.6 9.9 13.9 1.2 16.1 10.3 0.4 0 0.4 0.4 18 5 23 305 0 0 0 0 -4.9 0 -4.7 -5.1 11/10/2004 12:50:00 14 1 16.4 11.5 14.1 1 16.8 11.1 0.4 0 0.4 0.4 19 6 22 305 0 0 0 0 -4.9 0 -4.7 -5.1 11/10/2004 13:00:00 14.3 0.8 17.2 12.2 14.5 0.8 16.8 12.2 0.4 0 0.4 0.4 16 5 20 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/10/2004 13:10:00 14.2 1 16.4 11.1 14.4 1 16.8 11.1 0.4 0 0.4 0.4 15 5 15 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 13:20:00 13.9 1.1 16.8 11.1 14.1 1.2 17.2 11.1 0.4 0 0.4 0.4 16 5 12 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 13:30:00 14.3 0.8 16.4 12.2 14.5 1 17.2 11.5 0.4 0 0.4 0.4 15 5 9 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 13:40:00 14.4 0.8 16.4 12.2 14.4 0.9 16.8 11.5 0.4 0 0.4 0.4 25 4 25 305 0 0 0 0 -5.1 0 -4.9 -5.3 11/10/2004 13:50:00 13.9 1 16.8 11.8 14.1 1 17.2 11.8 0.4 0 0.4 0.4 18 6 11 305 0 0 0 0 -5.1 0 -4.9 -5.1 11/10/2004 14:00:00 14.3 0.9 16.4 12.2 14.4 1 17.2 11.8 0.4 0 0.4 0.4 20 6 18 305 0 0 0 0 -5.1 0.1 -4.9 -5.3 11/10/2004 14:10:00 14.4 0.8 16.4 12.2 14.5 0.9 17.2 12.2 0.4 0 0.4 0.4 21 4 24 305 0 0 0 0 -5.1 0 -4.9 -5.3 11/10/2004 14:20:00 14.5 1.2 16.8 10.7 14.5 1.2 17.2 11.1 0.4 0 0.4 0.4 24 5 28 305 0 0 0 0 -5.2 0.1 -4.9 -5.6 11/10/2004 14:30:00 14.3 0.9 16.8 11.8 14.4 1 17.2 11.5 0.4 0 0.4 0.4 24 4 22 305 0 0 0 0 -5.2 0.1 -4.9 -5.6 11/10/2004 14:40:00 14.1 0.9 16.8 11.5 14.2 0.9 16.8 11.8 0.4 0 0.4 0.4 24 5 20 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/10/2004 14:50:00 13.3 1 16.1 10.7 13.4 1.1 16.4 9.9 0.4 0 0.4 0.4 22 7 28 305 0 0 0 0 -5.2 0 -4.9 -5.6 11/10/2004 15:00:00 14 1.1 16.4 10.3 14.1 1.1 17.2 10.7 0.4 0 0.4 0.4 19 4 14 305 0 0 0 0 -5.5 0 -5.1 -5.6 11/10/2004 15:10:00 13.5 1 15.6 10.7 13.7 1 16.1 10.7 0.4 0 0.4 0.4 19 6 23 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/10/2004 15:20:00 13.4 1.3 17.6 10.7 13.5 1.3 17.2 9.9 0.4 0 0.4 0.4 18 5 21 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/10/2004 15:30:00 13.2 1.1 15.6 10.3 13.3 1.1 15.6 10.7 0.4 0 0.4 0.4 24 5 25 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/10/2004 15:40:00 13.2 0.9 15.6 11.1 13.4 1 15.6 10.7 0.4 0 0.4 0.4 20 7 30 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/10/2004 15:50:00 13.8 1.2 17.2 11.1 13.9 1.2 17.6 10.7 0.4 0 0.4 0.4 15 5 16 305 0 0 0 0 -5.3 0 -5.1 -5.6 11/10/2004 16:00:00 13.3 1.3 16.8 9.5 13.4 1.4 16.4 9.9 0.4 0 0.4 0.4 19 6 22 305 0 0 0 0 -5.3 0 -5.1 -5.6 11/10/2004 16:10:00 12.9 1.2 16.4 9.9 13.1 1.3 16.1 9.9 0.4 0 0.4 0.4 21 8 19 305 0 0 0 0 -5.1 0.1 -4.7 -5.6 11/10/2004 16:20:00 13.4 0.9 16.4 11.5 13.6 1 16.4 11.1 0.4 0 0.4 0.4 22 5 24 305 0 0 0 0 -5.1 0 -4.9 -5.3 11/10/2004 16:30:00 12.6 1.5 18.3 9.5 12.7 1.5 19.1 9.1 0.4 0 0.4 0.4 19 6 7 305 0 0 0 0 -5.1 0.1 -4.7 -5.3 11/10/2004 16:40:00 13.1 1.2 16.4 11.1 13.2 1.3 16.8 10.3 0.4 0 0.4 0.4 19 5 26 305 0 0 0 0 -5.1 0 -4.9 -5.3 11/10/2004 16:50:00 13.1 1.3 16.4 9.9 13.3 1.3 16.8 10.3 0.4 0 0.4 0.4 13 6 12 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 17:00:00 13.5 1.1 16.1 10.3 13.6 1.2 16.4 10.7 0.4 0 0.4 0.4 13 5 21 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 17:10:00 13.2 1.2 15.3 9.9 13.4 1.2 16.1 10.3 0.4 0 0.4 0.4 11 4 11 305 0 0 0 0 -5 0 -4.9 -5.3 11/10/2004 17:20:00 12.8 1 15.6 9.9 13 1.1 16.1 9.9 0.4 0 0.4 0.4 12 6 7 305 0 0 0 0 -4.9 0 -4.5 -5.1 11/10/2004 17:30:00 13.5 1 15.6 9.9 13.7 1.1 16.4 10.7 0.4 0 0.4 0.4 18 4 18 305 0 0 0 0 -4.9 0 -4.5 -5.1 11/10/2004 17:40:00 13.5 1.1 15.6 10.7 13.6 1.1 16.1 10.3 0.4 0 0.4 0.4 13 5 10 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 17:50:00 13.5 1 16.4 10.7 13.8 1.1 16.4 10.7 0.4 0 0.4 0.4 16 5 18 305 0 0 0 0 -5 0 -4.7 -5.1 11/10/2004 18:00:00 13.3 1.2 16.1 9.9 13.4 1.2 16.4 10.3 0.4 0 0.4 0.4 14 5 18 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/10/2004 18:10:00 13.5 1.3 16.4 10.3 13.7 1.3 16.4 10.7 0.4 0 0.4 0.4 13 4 16 305 0 0 0 0 -4.8 0.1 -4.7 -4.9 11/10/2004 18:20:00 13.6 1.3 16.1 10.3 13.7 1.3 16.1 10.3 0.4 0 0.4 0.4 18 6 19 305 0 0 0 0 -4.7 0 -4.5 -4.9 11/10/2004 18:30:00 13.7 0.8 15.6 11.5 13.9 0.9 16.1 11.5 0.4 0 0.4 0.4 17 6 14 305 0 0 0 0 -4.6 0 -4.5 -4.9 11/10/2004 18:40:00 13.7 1.4 16.4 9.9 13.9 1.4 16.8 10.3 0.4 0 0.4 0.4 20 6 17 305 0 0 0 0 -4.7 0 -4.5 -4.7 11/10/2004 18:50:00 13.8 1.5 17.9 10.3 14 1.5 18.3 10.7 0.4 0 0.4 0.4 16 5 11 305 0 0 0 0 -4.6 0.1 -4.5 -4.7 11/10/2004 19:00:00 13.3 1.1 16.4 9.9 13.4 1.1 16.4 10.3 0.4 0 0.4 0.4 16 6 5 305 0 0 0 0 -4.6 0 -4.5 -4.7 11/10/2004 19:10:00 13.6 1.2 16.4 11.1 13.7 1.3 16.8 10.3 0.4 0 0.4 0.4 22 5 25 305 0 0 0 0 -4.6 0 -4.5 -4.9 11/10/2004 19:20:00 13.8 1.1 16.4 10.3 14 1.1 16.8 10.3 0.4 0 0.4 0.4 14 6 11 305 0 0 0 0 -4.6 0 -4.2 -4.7 11/10/2004 19:30:00 13.6 1.1 16.4 10.7 13.7 1 16.4 11.1 0.4 0 0.4 0.4 18 7 11 305 0 0 0 0 -4.6 0.1 -4.5 -4.7 11/10/2004 19:40:00 13.5 1.1 16.4 10.3 13.6 1.2 16.1 10.7 0.4 0 0.4 0.4 16 6 17 305 0 0 0 0 -4.5 0 -4.5 -4.7 11/10/2004 19:50:00 13.3 1.1 15.6 10.7 13.4 1.1 16.1 10.3 0.4 0 0.4 0.4 21 7 28 305 0 0 0 0 -4.5 0 -4.2 -4.7 11/10/2004 20:00:00 12.4 1.2 14.9 8.8 12.4 1.3 15.3 8.8 0.4 0 0.4 0.4 20 7 14 305 0 0 0 0 -4.5 0.1 -4.2 -4.7 11/10/2004 20:10:00 13.2 1 15.6 10.3 13.2 1 15.6 9.9 0.4 0 0.4 0.4 24 6 27 305 0 0 0 0 -4.4 0 -4 -4.5 11/10/2004 20:20:00 13.4 1 15.3 10.7 13.6 1 15.6 10.3 0.4 0 0.4 0.4 21 5 27 305 0 0 0 0 -4.5 0 -4 -4.7 11/10/2004 20:30:00 13.6 0.9 15.6 10.7 13.7 0.9 15.6 11.5 0.4 0 0.4 0.4 19 7 32 305 0 0 0 0 -4.4 0 -4 -4.5 11/10/2004 20:40:00 13.4 1 16.1 11.1 13.5 1 16.1 10.7 0.4 0 0.4 0.4 21 6 19 305 0 0 0 0 -4.2 0 -3.8 -4.5 11/10/2004 20:50:00 13.6 1 15.6 11.1 13.7 1 16.1 10.3 0.4 0 0.4 0.4 18 4 13 305 0 0 0 0 -4.3 0 -4 -4.5 11/10/2004 21:00:00 12.8 1 15.3 9.9 13 1.1 15.6 10.3 0.4 0 0.4 0.4 17 7 13 305 0 0 0 0 -4.3 0 -4 -4.5 11/10/2004 21:10:00 13.2 1 15.3 10.3 13.3 1 15.3 10.3 0.4 0 0.4 0.4 15 4 16 305 0 0 0 0 -4.3 0 -4 -4.5 11/10/2004 21:20:00 12.9 1 14.9 9.9 13 1.1 15.6 9.9 0.4 0 0.4 0.4 18 7 13 305 0 0 0 0 -4.2 0 -4 -4.5 11/10/2004 21:30:00 13.3 1.2 16.4 10.3 13.5 1.2 16.1 9.9 0.4 0 0.4 0.4 15 5 15 305 0 0 0 0 -4.3 0 -4 -4.5 11/10/2004 21:40:00 12.9 1.2 15.6 10.3 13 1.2 15.6 10.7 0.4 0 0.4 0.4 16 4 9 305 0 0 0 0 -4.2 0 -4 -4.5 11/10/2004 21:50:00 13.4 1.2 15.6 10.3 13.5 1.2 16.1 10.3 0.4 0 0.4 0.4 16 5 12 305 0 0 0 0 -4.2 0 -4 -4.5 11/10/2004 22:00:00 13.1 1.2 15.6 9.9 13.2 1.2 16.1 10.3 0.4 0 0.4 0.4 19 5 30 305 0 0 0 0 -4.2 0 -4 -4.5 11/10/2004 22:10:00 12.7 1.1 15.3 9.5 12.9 1.1 15.6 9.5 0.4 0 0.4 0.4 19 5 14 305 0 0 0 0 -4 0 -3.8 -4.2 11/10/2004 22:20:00 12.7 1 15.6 9.9 12.8 1 15.6 9.9 0.4 0 0.4 0.4 20 5 14 305 0 0 0 0 -4.1 0 -4 -4.2 11/10/2004 22:30:00 13.2 1.1 15.6 10.3 13.4 1.1 16.1 10.7 0.4 0 0.4 0.4 20 5 25 305 0 0 0 0 -4.1 0 -4 -4.2 11/10/2004 22:40:00 12.6 1.1 16.1 8.8 12.8 1.1 16.4 8.4 0.4 0 0.4 0.4 27 8 27 305 0 0 0 0 -4.1 0 -3.3 -4.5 11/10/2004 22:50:00 12.5 1 14.9 9.1 12.6 1 14.9 9.5 0.4 0 0.4 0.4 23 4 19 305 0 0 0 0 -4.1 0 -3.8 -4.2 11/10/2004 23:00:00 12.7 1.2 16.1 9.9 12.8 1.3 16.1 9.5 0.4 0 0.4 0.4 24 5 21 305 0 0 0 0 -4.1 0 -3.8 -4.2 11/10/2004 23:10:00 12.7 1 15.3 10.3 12.7 1.1 15.3 10.3 0.4 0 0.4 0.4 26 6 25 305 0 0 0 0 -4.1 0 -3.6 -4.2 11/10/2004 23:20:00 12.4 1 14.5 9.9 12.5 1.1 15.3 9.5 0.4 0 0.4 0.4 22 5 19 305 0 0 0 0 -4 0 -3.8 -4.2 11/10/2004 23:30:00 13.1 0.8 15.3 10.7 13.2 0.8 15.3 10.7 0.4 0 0.4 0.4 20 6 27 305 0 0 0 0 -4 0 -3.3 -4.2 11/10/2004 23:40:00 13.1 1 15.3 10.7 13.2 0.9 15.3 10.7 0.4 0 0.4 0.4 25 5 25 305 0 0 0 0 -3.9 0 -3.3 -4 11/10/2004 23:50:00 13.1 0.8 15.6 11.1 13.2 0.9 15.6 11.1 0.4 0 0.4 0.4 24 6 22 305 0 0 0 0 -3.9 0 -3.3 -4 11/11/2004 00:00:00 12.8 1.1 16.1 10.3 12.9 1.1 16.1 10.3 0.4 0 0.4 0.4 19 5 18 305 0 0 0 0 -3.8 0 -3.3 -4 11/11/2004 00:10:00 13.1 1.1 15.6 10.3 13.2 1.2 15.6 9.9 0.4 0 0.4 0.4 24 6 22 305 0 0 0 0 -3.8 0.1 -3.1 -4 11/11/2004 00:20:00 13.3 1 15.6 10.7 13.4 1 15.6 10.3 0.4 0 0.4 0.4 25 4 18 305 0 0 0 0 -3.8 0 -3.3 -4 11/11/2004 00:30:00 12.8 1 15.3 9.9 12.9 1.1 15.3 9.5 0.4 0 0.4 0.4 19 6 30 305 0 0 0 0 -3.7 0.1 -3.1 -3.8 11/11/2004 00:40:00 13.3 1.2 15.6 9.9 13.4 1.2 16.1 10.7 0.4 0 0.4 0.4 18 6 17 305 0 0 0 0 -3.8 0.1 -3.3 -3.8 11/11/2004 00:50:00 13.5 0.8 15.3 11.1 13.7 0.8 15.6 11.5 0.4 0 0.4 0.4 17 5 12 305 0 0 0 0 -3.8 0 -3.3 -3.8 11/11/2004 01:00:00 13.4 0.8 16.1 11.1 13.6 0.9 16.1 10.7 0.4 0 0.4 0.4 18 3 17 305 0 0 0 0 -3.7 0.1 -3.1 -3.8 11/11/2004 01:10:00 13.5 1 16.1 11.1 13.6 1 16.1 10.7 0.4 0 0.4 0.4 20 4 18 305 0 0 0 0 -3.7 0.1 -3.1 -3.8 11/11/2004 01:20:00 13.1 1 15.3 10.3 13.3 1 16.1 10.7 0.4 0 0.4 0.4 23 6 18 305 0 0 0 0 -3.6 0.1 -3.1 -3.8 11/11/2004 01:30:00 13.3 1 16.1 10.3 13.3 1 15.6 10.3 0.4 0 0.4 0.4 25 5 26 305 0 0 0 0 -3.6 0 -3.1 -3.8 11/11/2004 01:40:00 13.3 0.8 14.9 10.7 13.4 1 15.6 9.9 0.4 0 0.4 0.4 22 5 21 305 0 0 0 0 -3.6 0 -3.1 -3.8 11/11/2004 01:50:00 12.6 1 14.9 10.3 12.7 1 15.6 10.3 0.4 0 0.4 0.4 21 5 26 305 0 0 0 0 -3.5 0 -3.1 -3.8 11/11/2004 02:00:00 13.1 1 15.6 9.5 13.1 1.1 16.1 9.9 0.4 0 0.4 0.4 25 5 26 305 0 0 0 0 -3.5 0 -2.9 -3.8 11/11/2004 02:10:00 13.4 0.9 15.6 10.3 13.5 1 15.3 9.9 0.4 0 0.4 0.4 28 5 25 305 0 0 0 0 -3.5 0 -3.1 -3.8 11/11/2004 02:20:00 13.2 1 15.3 10.7 13.2 1.1 15.3 10.3 0.4 0 0.4 0.4 24 5 28 305 0 0 0 0 -3.5 0 -2.9 -3.6 11/11/2004 02:30:00 12.8 1.1 15.6 10.3 12.9 1.2 16.1 9.9 0.4 0 0.4 0.4 23 6 22 305 0 0 0 0 -3.4 0 -2.9 -3.6 11/11/2004 02:40:00 12.9 0.9 14.9 9.9 13.1 1 14.9 9.9 0.4 0 0.4 0.4 26 6 29 305 0 0 0 0 -3.3 0 -2.7 -3.6 11/11/2004 02:50:00 13 0.9 14.9 10.3 13 1 15.6 10.7 0.4 0 0.4 0.4 24 6 15 305 0 0 0 0 -3.3 0 -2.9 -3.6 11/11/2004 03:00:00 13.1 1 15.6 10.7 13.1 1 16.1 10.3 0.4 0 0.4 0.4 29 5 33 305 0 0 0 0 -3.3 0 -2.7 -3.6 11/11/2004 03:10:00 13.2 1.1 16.1 9.9 13.3 1.2 16.1 9.5 0.4 0 0.4 0.4 28 6 33 305 0 0 0 0 -3.4 0 -3.3 -3.6 11/11/2004 03:20:00 13.3 1.1 16.1 10.3 13.4 1.2 16.8 10.3 0.4 0 0.4 0.4 23 4 23 305 0 0 0 0 -3.3 0 -3.1 -3.6 11/11/2004 03:30:00 13 1 15.3 10.3 13.1 1.1 15.3 10.3 0.4 0 0.4 0.4 23 5 19 305 0 0 0 0 -3.3 0 -2.9 -3.6 11/11/2004 03:40:00 12.5 1 14.9 9.9 12.6 1.1 14.9 9.5 0.4 0 0.4 0.4 20 5 21 305 0 0 0 0 -3.3 0 -3.1 -3.3 11/11/2004 03:50:00 13 1.2 15.3 10.3 13.1 1.2 15.6 9.9 0.4 0 0.4 0.4 19 4 21 305 0 0 0 0 -3.3 0 -2.7 -3.6 11/11/2004 04:00:00 12.2 0.8 14.5 10.3 12.3 1 15.3 9.9 0.4 0 0.4 0.4 25 5 16 305 0 0 0 0 -3.2 0 -2.7 -3.3 11/11/2004 04:10:00 12.1 0.8 13.7 9.9 12.2 0.8 14.1 9.9 0.4 0 0.4 0.4 31 4 25 305 0 0 0 0 -3.3 0 -2.7 -3.3 11/11/2004 04:20:00 12.6 0.9 14.9 9.9 12.6 1 14.9 9.9 0.4 0 0.4 0.4 32 5 30 305 0 0 0 0 -3.3 0 -2.7 -3.6 11/11/2004 04:30:00 12.4 0.8 14.1 9.5 12.3 1 14.5 9.5 0.4 0 0.4 0.4 28 4 30 305 0 0 0 0 -3.3 0 -2.9 -3.3 11/11/2004 04:40:00 12.3 0.8 14.5 9.9 12.3 0.8 14.5 9.9 0.4 0 0.4 0.4 30 4 23 305 0 0 0 0 -3.3 0 -2.9 -3.6 11/11/2004 04:50:00 11.9 0.9 14.1 9.9 12.1 0.9 14.5 9.1 0.4 0 0.4 0.4 32 5 29 305 0 0 0 0 -3.3 0 -2.9 -3.3 11/11/2004 05:00:00 12.1 0.8 13.7 9.5 12.2 0.8 14.1 9.5 0.4 0 0.4 0.4 28 5 32 305 0 0 0 0 -3.3 0 -2.7 -3.6 11/11/2004 05:10:00 12 0.8 14.1 10.3 12 0.8 14.1 9.9 0.4 0 0.4 0.4 34 4 34 305 0 0 0 0 -3.3 0 -2.7 -3.6 11/11/2004 05:20:00 12.3 0.9 14.5 9.9 12.3 0.9 14.1 9.9 0.4 0 0.4 0.4 35 4 33 305 0 0 0 0 -3.3 0 -2.7 -3.6 11/11/2004 05:30:00 11.6 0.8 13 9.1 11.6 0.8 13 8.8 0.4 0 0.4 0.4 36 4 41 305 0 0 0 0 -3.3 0 -3.1 -3.3 11/11/2004 05:40:00 11.8 0.8 13.7 9.9 11.8 0.9 13.7 8.8 0.4 0 0.4 0.4 36 4 36 305 0 0 0 0 -3.4 0 -3.3 -3.6 11/11/2004 05:50:00 11.5 0.9 13.7 9.1 11.6 0.8 13.3 9.1 0.4 0 0.4 0.4 30 5 36 305 0 0 0 0 -3.3 0 -3.3 -3.6 11/11/2004 06:00:00 11.3 1 13.3 8.8 11.4 1 13.3 8 0.4 0 0.4 0.4 21 5 27 305 0 0 0 0 -3.3 0 -2.7 -3.3 11/11/2004 06:10:00 11.6 0.7 13.7 9.5 11.7 0.8 13.3 9.5 0.4 0 0.4 0.4 21 5 22 305 0 0 0 0 -3.3 0 -3.1 -3.3 11/11/2004 06:20:00 11.1 0.8 13 8.8 11.3 0.9 13.3 8.4 0.4 0 0.4 0.4 20 5 21 305 0 0 0 0 -3.2 0 -3.1 -3.3 11/11/2004 06:30:00 10.9 0.8 13 8.8 11.1 0.9 13.3 8.8 0.4 0 0.4 0.4 20 6 18 305 0 0 0 0 -3.2 0 -3.1 -3.3 11/11/2004 06:40:00 11 1 14.5 8 11.1 1.1 15.3 8 0.4 0 0.4 0.4 20 8 19 305 0 0 0 0 -3.2 0 -2.7 -3.3 11/11/2004 06:50:00 10.6 0.7 12.6 8.8 10.6 0.7 12.6 8.4 0.4 0 0.4 0.4 28 7 41 305 0 0 0 0 -3.2 0 -2.9 -3.3 11/11/2004 07:00:00 11 0.7 13 9.1 11.1 0.8 13 9.1 0.4 0 0.4 0.4 36 4 37 305 0 0 0 0 -3.2 0.1 -2.7 -3.3 11/11/2004 07:10:00 10.8 0.8 13 8.8 10.9 0.8 13 8.8 0.4 0 0.4 0.4 34 5 33 305 0 0 0 0 -3.1 0 -2.7 -3.1 11/11/2004 07:20:00 11.4 0.8 13.3 8.8 11.3 0.9 13.3 8.8 0.4 0 0.4 0.4 33 5 33 305 0 0 0 0 -3.1 0 -2.9 -3.3 11/11/2004 07:30:00 11.2 0.6 13 9.9 11.3 0.6 13 9.5 0.4 0 0.4 0.4 36 5 37 305 0 0 0 0 -3.1 0 -2.9 -3.3 11/11/2004 07:40:00 10.8 0.9 13 8.4 10.9 1 13.3 8.4 0.4 0 0.4 0.4 32 7 26 305 0 0 0 0 -3.1 0 -2.9 -3.3 11/11/2004 07:50:00 10.5 0.8 12.2 8.4 10.5 0.8 12.6 8 0.4 0 0.4 0.4 31 5 35 305 0 0 0 0 -3 0 -2.4 -3.1 11/11/2004 08:00:00 10.1 0.7 12.2 8.4 10.2 0.7 12.2 8.4 0.4 0 0.4 0.4 34 4 33 305 0 0 0 0 -3 0 -2.4 -3.1 11/11/2004 08:10:00 10.5 0.7 11.8 8.4 10.5 0.8 12.2 8.4 0.4 0 0.4 0.4 39 5 41 305 0 0 0 0 -3.1 0 -2.7 -3.1 11/11/2004 08:20:00 10.5 0.8 12.6 8.4 10.6 0.9 12.2 8.4 0.4 0 0.4 0.4 33 4 31 305 0 0 0 0 -3.1 0 -2.7 -3.3 11/11/2004 08:30:00 10 0.6 11.5 8.4 10.1 0.6 11.8 8.4 0.4 0 0.4 0.4 26 5 31 305 0 0 0 0 -3 0 -2.4 -3.1 11/11/2004 08:40:00 9.8 0.7 11.5 8 9.9 0.7 11.5 7.6 0.4 0 0.4 0.4 27 5 28 305 0 0 0 0 -2.9 0 -2.4 -3.1 11/11/2004 08:50:00 10.2 0.7 12.2 8.8 10.4 0.7 12.2 8.4 0.4 0 0.4 0.4 27 5 23 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 09:00:00 10.4 0.7 12.2 8.4 10.5 0.8 13 8.4 0.4 0 0.4 0.4 26 4 25 305 0 0 0 0 -2.8 0 -2.2 -2.9 11/11/2004 09:10:00 10.2 0.6 12.2 8.8 10.4 0.6 11.8 8.8 0.4 0 0.4 0.4 24 4 23 305 0 0 0 0 -2.7 0 -2.2 -2.9 11/11/2004 09:20:00 10.6 0.8 12.2 8 10.8 0.8 12.6 8.4 0.4 0 0.4 0.4 24 5 31 305 0 0 0 0 -2.7 0 -2.2 -2.9 11/11/2004 09:30:00 10.7 0.6 12.2 9.1 10.8 0.7 12.6 9.1 0.4 0 0.4 0.4 22 5 22 305 0 0 0 0 -2.8 0 -2.2 -2.9 11/11/2004 09:40:00 10.3 0.7 12.2 8.4 10.3 0.8 12.6 8.4 0.4 0 0.4 0.4 25 4 24 305 0 0 0 0 -2.7 0 -2.2 -2.9 11/11/2004 09:50:00 10.6 0.8 12.6 8.8 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 29 4 25 305 0 0 0 0 -2.8 0 -2.2 -2.9 11/11/2004 10:00:00 10.5 0.6 13 8.8 10.5 0.6 12.6 8.8 0.4 0 0.4 0.4 28 4 21 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 10:10:00 10.3 0.6 11.5 8.4 10.3 0.7 11.8 8 0.4 0 0.4 0.4 27 5 22 305 0 0 0 0 -2.8 0 -2.4 -2.9 11/11/2004 10:20:00 10.3 0.6 12.2 8.4 10.3 0.7 11.8 8.4 0.4 0 0.4 0.4 27 5 32 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 10:30:00 10.1 0.8 11.8 8 10.1 0.7 11.8 8.4 0.4 0 0.4 0.4 30 5 24 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 10:40:00 10.1 0.7 11.8 8.4 10.2 0.8 12.2 8.4 0.4 0 0.4 0.4 30 5 30 305 0 0 0 0 -2.9 0 -2.4 -3.1 11/11/2004 10:50:00 10.3 0.8 12.6 8 10.4 0.9 13 7.6 0.4 0 0.4 0.4 27 4 25 305 0 0 0 0 -2.9 0 -2.4 -3.1 11/11/2004 11:00:00 9.8 0.7 11.8 8 9.8 0.7 12.2 8.4 0.4 0 0.4 0.4 27 5 26 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 11:10:00 9.9 0.6 11.5 8 10 0.7 11.5 7.6 0.4 0 0.4 0.4 26 4 18 305 0 0 0 0 -2.9 0 -2.7 -3.1 11/11/2004 11:20:00 10.1 0.8 11.8 7.6 10.1 0.8 11.8 8 0.4 0 0.4 0.4 27 4 29 305 0 0 0 0 -2.9 0 -2.7 -3.1 11/11/2004 11:30:00 9.9 0.7 11.5 8 10 0.7 11.8 8 0.4 0 0.4 0.4 25 4 19 305 0 0 0 0 -3 0 -2.7 -3.1 11/11/2004 11:40:00 9.8 0.6 11.5 8 9.9 0.6 11.8 8.4 0.4 0 0.4 0.4 24 4 28 305 0 0 0 0 -3 0 -2.7 -3.1 11/11/2004 11:50:00 9.5 0.8 12.2 7.6 9.7 0.8 11.8 7.6 0.4 0 0.4 0.4 26 5 27 305 0 0 0 0 -3 0 -2.7 -3.1 11/11/2004 12:00:00 9.6 0.7 11.5 7.2 9.7 0.8 11.8 7.2 0.4 0 0.4 0.4 27 5 40 305 0 0 0 0 -3 0 -2.4 -3.1 11/11/2004 12:10:00 9.6 0.6 11.1 8 9.7 0.7 11.1 8 0.4 0 0.4 0.4 27 5 26 305 0 0 0 0 -3 0 -2.9 -3.1 11/11/2004 12:20:00 9 0.7 10.3 6.8 9.1 0.7 11.1 6.8 0.4 0 0.4 0.4 27 5 25 305 0 0 0 0 -3 0 -2.7 -3.1 11/11/2004 12:30:00 9.4 0.6 11.1 8 9.6 0.7 12.2 7.2 0.4 0 0.4 0.4 24 6 16 305 0 0 0 0 -3.1 0 -2.7 -3.1 11/11/2004 12:40:00 8.8 0.7 10.7 7.2 8.9 0.7 11.1 6.8 0.4 0 0.4 0.4 30 6 28 305 0 0 0 0 -3 0 -2.7 -3.1 11/11/2004 12:50:00 9 0.5 10.3 7.2 9.2 0.5 10.7 8 0.4 0 0.4 0.4 26 4 24 305 0 0 0 0 -3 0 -2.7 -3.1 11/11/2004 13:00:00 9.1 0.6 10.7 7.2 9.3 0.7 11.1 6.8 0.4 0 0.4 0.4 30 4 27 305 0 0 0 0 -3 0 -2.4 -3.1 11/11/2004 13:10:00 9.1 0.7 10.7 7.2 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 32 4 37 305 0 0 0 0 -3 0 -2.7 -3.1 11/11/2004 13:20:00 9 0.6 10.7 7.6 9.1 0.7 11.1 7.2 0.4 0 0.4 0.4 33 5 40 305 0 0 0 0 -2.9 0 -2.4 -3.1 11/11/2004 13:30:00 8.8 0.7 10.3 6.8 9 0.7 10.7 7.2 0.4 0 0.4 0.4 36 6 33 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 13:40:00 8.4 0.6 10.3 6.5 8.5 0.7 9.9 6.1 0.4 0 0.4 0.4 30 4 31 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 13:50:00 8.4 0.6 9.5 6.5 8.5 0.6 9.9 6.5 0.4 0 0.4 0.4 30 5 27 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 14:00:00 8.3 0.5 9.5 7.2 8.4 0.5 9.9 6.5 0.4 0 0.4 0.4 26 4 21 305 0 0 0 0 -2.8 0 -2.4 -2.9 11/11/2004 14:10:00 8.1 0.6 9.9 6.8 8.3 0.6 10.3 6.8 0.4 0 0.4 0.4 25 4 26 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 14:20:00 8.1 0.6 9.1 6.1 8.3 0.7 9.5 6.5 0.4 0 0.4 0.4 25 4 29 305 0 0 0 0 -2.8 0 -2.4 -2.9 11/11/2004 14:30:00 7.8 0.6 9.5 6.1 8 0.7 9.9 5.7 0.4 0 0.4 0.4 27 5 26 305 0 0 0 0 -2.8 0 -2.4 -2.9 11/11/2004 14:40:00 7.8 0.7 9.5 6.5 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 31 5 32 305 0 0 0 0 -2.8 0 -2.7 -2.9 11/11/2004 14:50:00 7.9 0.6 9.1 6.1 7.9 0.7 9.5 5.7 0.4 0 0.4 0.4 27 5 36 305 0 0 0 0 -2.8 0 -2.7 -2.9 11/11/2004 15:00:00 7.8 0.6 9.5 5.7 8 0.6 9.5 5.7 0.4 0 0.4 0.4 27 5 29 305 0 0 0 0 -2.8 0 -2.2 -2.7 11/11/2004 15:10:00 8 0.5 9.1 6.8 8.1 0.5 9.5 7.2 0.4 0 0.4 0.4 27 4 27 305 0 0 0 0 -2.8 0 -2.7 -2.9 11/11/2004 15:20:00 7.9 0.6 9.1 6.5 8 0.7 9.9 6.5 0.4 0 0.4 0.4 27 5 26 305 0 0 0 0 -2.8 0 -2.7 -2.9 11/11/2004 15:30:00 7.7 0.6 9.1 6.1 7.9 0.6 9.5 6.5 0.4 0 0.4 0.4 23 3 18 305 0 0 0 0 -2.8 0 -2.7 -2.9 11/11/2004 15:40:00 7.5 0.6 9.1 6.1 7.7 0.7 9.5 6.1 0.4 0 0.4 0.4 24 4 21 305 0 0 0 0 -2.8 0 -2.7 -2.9 11/11/2004 15:50:00 7.5 0.5 8.8 6.1 7.6 0.5 9.1 6.1 0.4 0 0.4 0.4 25 4 23 305 0 0 0 0 -2.9 0 -2.7 -3.1 11/11/2004 16:00:00 7.4 0.5 8.8 6.1 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 25 4 27 305 0 0 0 0 -3 0 -2.7 -3.1 11/11/2004 16:10:00 7.2 0.4 8.4 6.1 7.4 0.5 8.8 6.1 0.4 0 0.4 0.4 28 5 31 305 0 0 0 0 -3 0 -2.9 -3.1 11/11/2004 16:20:00 6.9 0.5 8 5.7 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 26 4 30 305 0 0 0 0 -3.1 0 -2.7 -3.1 11/11/2004 16:30:00 6.5 0.6 8 4.6 6.6 0.6 8 4.6 0.4 0 0.4 0.4 30 7 41 305 0 0 0 0 -3.1 0 -3.1 -3.3 11/11/2004 16:40:00 6.3 0.4 7.2 4.9 6.4 0.5 7.6 5.3 0.4 0 0.4 0.4 28 6 32 305 0 0 0 0 -3.2 0 -3.1 -3.3 11/11/2004 16:50:00 6.7 0.5 7.6 5.3 6.8 0.5 8 5.3 0.4 0 0.4 0.4 25 5 23 305 0 0 0 0 -3.2 0 -3.1 -3.3 11/11/2004 17:00:00 6.4 0.4 7.2 5.3 6.5 0.5 8 5.3 0.4 0 0.4 0.4 33 5 33 305 0 0 0 0 -3.2 0 -3.1 -3.3 11/11/2004 17:10:00 6.1 0.6 7.6 4.6 6.2 0.6 7.6 4.9 0.4 0 0.4 0.4 27 6 32 305 0 0 0 0 -3.1 0 -2.7 -3.3 11/11/2004 17:20:00 6.1 0.5 7.6 4.9 6.3 0.5 7.6 5.3 0.4 0 0.4 0.4 23 5 30 305 0 0 0 0 -3.2 0.1 -2.7 -3.3 11/11/2004 17:30:00 5.9 0.4 6.8 4.9 6.1 0.5 7.2 4.9 0.4 0 0.4 0.4 25 4 15 305 0 0 0 0 -3.2 0 -2.7 -3.3 11/11/2004 17:40:00 5.6 0.4 6.8 4.2 5.7 0.5 7.2 4.6 0.4 0 0.4 0.4 31 5 29 305 0 0 0 0 -3.2 0 -2.7 -3.3 11/11/2004 17:50:00 5.5 0.5 6.8 3.8 5.7 0.5 7.2 4.2 0.4 0 0.4 0.4 25 7 19 305 0 0 0 0 -3.1 0 -2.7 -3.3 11/11/2004 18:00:00 5.3 0.5 6.5 3.4 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 24 5 26 305 0 0 0 0 -3.1 0 -2.7 -3.3 11/11/2004 18:10:00 5.8 0.5 6.8 4.6 6.1 0.4 7.2 4.9 0.4 0 0.4 0.4 20 5 18 305 0 0 0 0 -3 0 -2.7 -3.1 11/11/2004 18:20:00 5.6 0.5 6.8 4.6 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 19 4 24 305 0 0 0 0 -3.1 0 -2.7 -3.1 11/11/2004 18:30:00 5.6 0.5 6.8 3.8 5.9 0.5 7.2 4.2 0.4 0 0.4 0.4 16 5 17 305 0 0 0 0 -3 0 -2.4 -3.1 11/11/2004 18:40:00 5.7 0.5 6.8 4.6 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 14 6 19 305 0 0 0 0 -3 0 -2.9 -3.1 11/11/2004 18:50:00 5.6 0.5 6.8 3.8 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 17 5 16 305 0 0 0 0 -3 0 -2.4 -3.1 11/11/2004 19:00:00 5.5 0.5 6.5 4.6 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 17 5 21 305 0 0 0 0 -3 0 -2.4 -3.1 11/11/2004 19:10:00 5.6 0.5 7.2 4.6 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 17 5 12 305 0 0 0 0 -2.9 0 -2.4 -3.1 11/11/2004 19:20:00 5.4 0.4 6.5 4.2 5.6 0.4 6.8 4.6 0.4 0 0.4 0.4 19 6 13 305 0 0 0 0 -2.9 0 -2.7 -3.1 11/11/2004 19:30:00 5.4 0.5 6.5 4.2 5.6 0.4 6.8 4.6 0.4 0 0.4 0.4 19 5 22 305 0 0 0 0 -2.9 0 -2.7 -3.1 11/11/2004 19:40:00 5.1 0.4 6.5 3.8 5.3 0.4 6.5 4.2 0.4 0 0.4 0.4 25 5 33 305 0 0 0 0 -2.8 0 -2.7 -3.1 11/11/2004 19:50:00 4.9 0.4 6.1 3.8 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 19 6 15 305 0 0 0 0 -2.9 0 -2.7 -3.1 11/11/2004 20:00:00 4.4 0.5 5.3 3.4 4.7 0.5 5.7 3.4 0.4 0 0.4 0.4 22 7 15 305 0 0 0 0 -2.8 0 -2.4 -2.9 11/11/2004 20:10:00 4.7 0.4 5.3 3.8 5 0.4 5.7 4.2 0.4 0 0.4 0.4 21 5 15 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 20:20:00 4.7 0.5 5.7 3.4 4.9 0.5 6.1 3.8 0.4 0 0.4 0.4 30 8 36 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 20:30:00 4.8 0.5 5.7 3.8 5 0.5 6.1 3.8 0.4 0 0.4 0.4 33 6 36 305 0 0 0 0 -2.9 0 -2.4 -3.1 11/11/2004 20:40:00 5 0.5 6.1 3.8 5.2 0.5 6.5 3.8 0.4 0 0.4 0.4 24 4 22 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 20:50:00 4.8 0.4 5.7 3.8 5 0.4 6.1 3.8 0.4 0 0.4 0.4 22 6 21 305 0 0 0 0 -2.8 0 -2.4 -3.1 11/11/2004 21:00:00 4.9 0.4 6.1 3.4 5.1 0.4 6.1 3.8 0.4 0 0.4 0.4 26 4 27 305 0 0 0 0 -2.8 0 -2.4 -2.9 11/11/2004 21:10:00 4.5 0.4 5.7 3.4 4.6 0.5 5.7 3.4 0.4 0 0.4 0.4 25 6 17 305 0 0 0 0 -2.8 0 -2.7 -3.1 11/11/2004 21:20:00 4.4 0.5 5.3 3 4.6 0.5 6.1 3.4 0.4 0 0.4 0.4 25 6 21 305 0 0 0 0 -2.8 0 -2.7 -2.9 11/11/2004 21:30:00 4.4 0.5 5.7 3 4.6 0.5 5.7 3.4 0.4 0 0.4 0.4 29 5 25 305 0 0 0 0 -2.8 0 -2.2 -2.9 11/11/2004 21:40:00 4.5 0.4 5.7 3.4 4.6 0.4 6.1 3.8 0.4 0 0.4 0.4 31 5 31 305 0 0 0 0 -2.8 0 -2.2 -2.9 11/11/2004 21:50:00 4.5 0.4 5.3 3.8 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 31 6 24 305 0 0 0 0 -2.8 0 -2.2 -2.9 11/11/2004 22:00:00 4 0.4 5.3 3 4.2 0.5 5.7 3.4 0.4 0 0.4 0.4 31 6 35 305 0 0 0 0 -2.8 0 -2.2 -2.9 11/11/2004 22:10:00 4.7 0.5 6.8 3.4 4.8 0.5 6.5 3.8 0.4 0 0.4 0.4 34 5 35 305 0 0 0 0 -2.8 0 -2.2 -2.7 11/11/2004 22:20:00 4.8 0.4 5.7 3.8 4.9 0.4 6.1 4.2 0.4 0 0.4 0.4 32 4 33 305 0 0 0 0 -2.7 0 -2.2 -2.7 11/11/2004 22:30:00 4.8 0.4 6.1 3.8 5 0.4 6.1 3.8 0.4 0 0.4 0.4 36 6 34 305 0 0 0 0 -2.7 0 -2 -2.7 11/11/2004 22:40:00 4.6 0.3 5.3 3.8 4.7 0.4 5.7 3.8 0.4 0 0.4 0.4 34 4 40 305 0 0 0 0 -2.7 0 -2.2 -2.7 11/11/2004 22:50:00 4.2 0.4 5.3 3.4 4.5 0.4 5.7 3.4 0.4 0 0.4 0.4 34 5 34 305 0 0 0 0 -2.7 0.1 -2.2 -2.7 11/11/2004 23:00:00 4.5 0.5 5.7 3 4.7 0.5 5.7 3.4 0.4 0 0.4 0.4 34 6 39 305 0 0 0 0 -2.6 0 -2.2 -2.7 11/11/2004 23:10:00 4.3 0.5 5.3 3 4.6 0.5 5.7 3 0.4 0 0.4 0.4 41 6 38 305 0 0 0 0 -2.6 0 -2.2 -2.7 11/11/2004 23:20:00 3.6 0.5 4.9 2.3 3.9 0.5 4.9 2.6 0.4 0 0.4 0.4 34 5 39 305 0 0 0 0 -2.6 0 -2.2 -2.7 11/11/2004 23:30:00 3.8 0.4 4.6 2.6 4.1 0.4 4.9 3.4 0.4 0 0.4 0.4 35 4 34 305 0 0 0 0 -2.6 0 -2.4 -2.7 11/11/2004 23:40:00 3.4 0.4 4.6 2.6 3.7 0.4 4.9 2.6 0.4 0 0.4 0.4 41 9 38 305 0 0 0 0 -2.6 0 -2.4 -2.7 11/11/2004 23:50:00 2.8 0.5 4.2 1.5 3.1 0.5 4.2 1.9 0.4 0 0.4 0.4 38 7 39 305 0 0 0 0 -2.6 0 -2.4 -2.7 11/12/2004 00:00:00 2.6 0.4 3.4 1.9 2.8 0.3 3.8 1.9 0.4 0 0.4 0.4 41 13 45 305 0 0 0 0 -2.5 0 -2 -2.7 11/12/2004 00:10:00 2.3 0.6 3.8 1.1 2.5 0.5 3.8 1.5 0.4 0 0.4 0.4 43 10 58 305 0 0 0 0 -2.5 0 -2 -2.7 11/12/2004 00:20:00 1.6 0.9 3 0.4 2 0.7 3.4 0.4 0.4 0 0.4 0.4 47 8 52 305 0 0 0 0 -2.5 0 -2 -2.7 11/12/2004 00:30:00 2 0.4 2.6 0.4 2.3 0.3 3.4 1.1 0.4 0 0.4 0.4 33 5 37 305 0 0 0 0 -2.5 0 -2 -2.7 11/12/2004 00:40:00 1.6 0.5 2.6 0.4 1.9 0.4 3 0.7 0.4 0 0.4 0.4 43 16 62 305 0 0 0 0 -2.4 0 -2 -2.7 11/12/2004 00:50:00 1.7 0.4 2.6 0.7 2 0.4 3 1.1 0.4 0 0.4 0.4 35 15 25 305 0 0 0 0 -2.6 0 -2 -2.7 11/12/2004 01:00:00 1.6 0.5 2.6 0.7 2.1 0.4 3 1.1 0.4 0 0.4 0.4 27 11 27 305 0 0 0 0 -2.6 0.1 -2 -2.7 11/12/2004 01:10:00 2 0.4 3 1.1 2.3 0.3 3 1.9 0.4 0 0.4 0.4 34 9 17 305 0 0 0 0 -2.7 0.1 -2.2 -2.7 11/12/2004 01:20:00 2 0.3 2.6 1.1 2.3 0.3 3 1.9 0.4 0 0.4 0.4 40 6 41 305 1 0 0 0 -2.7 0 -2.2 -2.9 11/12/2004 01:30:00 2.1 0.4 3 1.5 2.5 0.3 3 1.9 0.4 0 0.4 0.4 42 7 52 305 1 0 1 0 -2.8 0 -2.4 -2.9 11/12/2004 01:40:00 1.9 0.4 3 0.7 2.3 0.3 3.4 1.5 0.4 0 0.4 0.4 38 5 43 305 1 0 1 0 -2.8 0 -2.2 -2.7 11/12/2004 01:50:00 1.9 0.5 3 0.7 2.3 0.4 3.4 1.5 0.4 0 0.4 0.4 40 6 47 305 1 0 1 0 -2.8 0 -2.4 -2.9 11/12/2004 02:00:00 0.5 0.3 1.5 0.4 1.1 0.5 1.9 0.4 0.4 0 0.4 0.4 33 2 34 305 1 0 1 0 -2.7 0.1 -2.2 -2.7 11/12/2004 02:10:00 0.4 0 0.7 0.4 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 35 2 35 305 1 0 1 0 -2.7 0.1 -2 -2.7 11/12/2004 02:20:00 0.5 0.2 1.1 0.4 1.4 0.2 1.9 0.7 0.4 0 0.4 0.4 55 12 44 305 1 0 1 0 -2.7 0 -2.2 -2.9 11/12/2004 02:30:00 0.4 0 0.4 0.4 1.1 0.3 1.9 0.4 0.4 0 0.4 0.4 53 8 305 305 1 0 1 0 -2.8 0 -2.4 -3.1 11/12/2004 02:40:00 0.6 0.4 1.5 0.4 1.7 0.3 2.3 1.1 0.4 0 0.4 0.4 54 7 59 305 1 0 1 0 -2.8 0 -2.4 -3.1 11/12/2004 02:50:00 1.3 0.4 2.3 0.4 1.8 0.3 2.6 1.1 0.4 0 0.4 0.4 55 7 65 305 1 0 1 0 -2.8 0 -2.4 -2.9 11/12/2004 03:00:00 0.5 0.3 1.5 0.4 1.4 0.3 2.3 0.7 0.4 0 0.4 0.4 41 4 48 305 1 0 1 0 -2.7 0 -2.2 -2.7 11/12/2004 03:10:00 0.4 0 0.4 0.4 0.7 0.3 1.9 0.4 0.4 0 0.4 0.4 52 3 305 305 1 0 1 0 -2.7 0 -2.2 -2.9 11/12/2004 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 305 305 1 0 0 0 -2.8 0 -2.2 -2.9 11/12/2004 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 305 305 1 0 0 0 -2.8 0 -2.4 -2.9 11/12/2004 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 305 305 1 0 0 0 -2.8 0 -2.2 -2.9 11/12/2004 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 305 305 1 0 0 0 -2.8 0 -2.4 -3.1 11/12/2004 04:00:00 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 109 35 305 305 1 0 1 0 -2.9 0 -2.4 -3.1 11/12/2004 04:10:00 0.4 0 0.4 0.4 1 0.3 1.5 0.4 0.4 0 0.4 0.4 184 16 305 305 1 0 1 0 -3.1 0 -2.7 -3.1 11/12/2004 04:20:00 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 198 6 305 305 1 0 1 0 -3 0 -2.4 -3.1 11/12/2004 04:30:00 0.4 0.1 1.1 0.4 0.9 0.3 1.9 0.4 0.4 0 0.4 0.4 200 12 210 305 1 0 1 0 -3 0 -2.7 -3.1 11/12/2004 04:40:00 1.5 0.8 3 0.4 2 0.6 3 0.7 0.4 0 0.4 0.4 203 8 203 305 1 0 1 0 -3 0 -2.7 -3.1 11/12/2004 04:50:00 2.3 0.3 3 1.5 2.7 0.2 3.4 2.3 0.4 0 0.4 0.4 204 4 203 305 1 0 1 0 -2.8 0 -2.4 -2.9 11/12/2004 05:00:00 3.1 0.3 3.8 2.3 3.3 0.3 3.8 2.6 0.4 0 0.4 0.4 202 5 211 305 1 0 1 0 -2.8 0 -2.4 -2.9 11/12/2004 05:10:00 3 0.3 3.8 2.3 3.3 0.3 4.2 2.3 0.4 0 0.4 0.4 196 6 202 305 1 0 1 0 -2.8 0 -2.7 -2.9 11/12/2004 05:20:00 2.8 0.3 3.4 1.9 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 193 5 194 305 1 0 1 0 -2.9 0 -2.7 -3.1 11/12/2004 05:30:00 2.1 0.6 3.4 0.4 3 0.4 3.8 1.9 0.4 0 0.4 0.4 180 5 181 305 1 0 1 0 -3.1 0 -3.1 -3.3 11/12/2004 05:40:00 2.9 0.5 3.8 1.1 3.2 0.4 4.2 2.3 0.4 0 0.4 0.4 186 3 186 305 1 0 1 0 -3.2 0 -2.7 -3.3 11/12/2004 05:50:00 3 0.7 4.6 1.1 3.5 0.4 4.6 2.3 0.4 0 0.4 0.4 186 6 194 305 1 0 1 0 -3.3 0 -3.1 -3.3 11/12/2004 06:00:00 4.8 0.3 5.3 3.8 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 193 2 192 305 1 0 1 0 -3.3 0 -2.7 -3.3 11/12/2004 06:10:00 4.9 0.3 5.3 3.8 5.1 0.3 5.7 4.2 0.4 0 0.4 0.4 191 2 192 305 1 0 1 0 -3.3 0 -3.1 -3.3 11/12/2004 06:20:00 4.2 0.6 5.3 2.6 4.7 0.4 5.7 3.4 0.4 0 0.4 0.4 186 3 191 305 1 0 1 0 -3.3 0 -3.1 -3.6 11/12/2004 06:30:00 3.8 0.5 4.9 2.3 4.3 0.3 4.9 3.4 0.4 0 0.4 0.4 185 3 191 305 1 0 1 0 -3.3 0 -2.9 -3.3 11/12/2004 06:40:00 2.3 0.5 3.8 1.1 3.9 0.3 4.6 3 0.4 0 0.4 0.4 175 5 180 305 1 0 1 0 -3.3 0 -3.1 -3.3 11/12/2004 06:50:00 1.9 0.5 3.8 1.1 3.8 0.3 4.6 3 0.4 0 0.4 0.4 171 3 177 305 1 0 1 0 -3.3 0 -2.7 -3.6 11/12/2004 07:00:00 1.9 0.4 3 0.7 3.8 0.3 4.6 3 0.4 0 0.4 0.4 171 5 177 305 1 0 1 0 -3.5 0 -2.9 -3.8 11/12/2004 07:10:00 2.2 0.6 3.8 0.7 3.8 0.4 4.6 2.6 0.4 0 0.4 0.4 176 4 184 305 1 0 1 0 -3.6 0 -3.3 -3.8 11/12/2004 07:20:00 2 0.6 3.4 0.7 3.5 0.4 4.6 2.3 0.4 0 0.4 0.4 171 7 165 305 1 0 1 0 -3.3 0 -2.7 -3.6 11/12/2004 07:30:00 2.1 0.7 3.8 0.4 3.2 0.5 4.2 1.5 0.4 0 0.4 0.4 176 7 194 305 1 0 1 0 -3.3 0 -2.7 -3.3 11/12/2004 07:40:00 2.8 0.7 4.6 1.1 3.5 0.5 4.9 2.6 0.4 0 0.4 0.4 170 15 192 305 1 0 0 0 -3.2 0.1 -2.7 -3.3 11/12/2004 07:50:00 2.2 0.6 3.4 0.4 2.8 0.4 3.8 2.3 0.4 0 0.4 0.4 152 10 165 305 1 0 1 0 -3.2 0 -2.7 -3.3 11/12/2004 08:00:00 3.5 0.5 4.6 2.3 3.7 0.4 4.6 2.6 0.4 0 0.4 0.4 150 7 150 305 1 0 1 0 -3.3 0 -2.7 -3.6 11/12/2004 08:10:00 3.1 0.8 4.6 0.7 3.9 0.5 4.9 2.3 0.4 0 0.4 0.4 160 7 152 305 1 0 1 0 -3.3 0 -2.7 -3.3 11/12/2004 08:20:00 3.6 0.7 5.3 1.9 4 0.4 5.3 3 0.4 0 0.4 0.4 156 5 156 305 1 0 0 0 -3.5 0.1 -2.9 -3.8 11/12/2004 08:30:00 4.3 0.7 5.7 2.3 4.7 0.4 5.7 3.8 0.4 0 0.4 0.4 160 3 156 305 0 0 0 0 -3.8 0 -3.3 -3.8 11/12/2004 08:40:00 3.4 0.8 5.3 1.9 4.6 0.4 5.7 3.8 0.4 0 0.4 0.4 164 2 161 305 0 0 0 0 -4 0.1 -3.3 -4.2 11/12/2004 08:50:00 4.1 0.4 5.3 3 4.3 0.3 4.9 3.4 0.4 0 0.4 0.4 159 3 160 305 0 0 0 0 -4.4 0 -3.8 -4.7 11/12/2004 09:00:00 3.9 0.4 4.6 3 4 0.3 4.6 3 0.4 0 0.4 0.4 144 3 148 305 0 0 0 0 -4.9 0.1 -4.5 -5.1 11/12/2004 09:10:00 3.8 0.6 4.9 1.9 3.7 0.5 4.6 2.3 0.4 0 0.4 0.4 136 8 137 305 0 0 0 0 -5.2 0 -5.1 -5.6 11/12/2004 09:20:00 2.3 1 4.6 0.4 2.6 0.8 4.9 1.1 0.4 0 0.4 0.4 127 22 135 305 0 0 0 0 -4.7 0.2 -4.2 -5.1 11/12/2004 09:30:00 4.4 1.9 8 0.4 4.4 1.7 7.6 1.1 0.4 0 0.4 0.4 131 15 140 305 1 0 0 0 -4.1 0.2 -3.8 -4.5 11/12/2004 09:40:00 7.7 0.5 8.8 6.1 7.5 0.5 8.4 6.1 0.4 0 0.4 0.4 140 3 144 305 1 0 1 0 -3.9 0 -3.1 -4 11/12/2004 09:50:00 7.9 0.7 9.1 6.1 7.7 0.7 9.1 6.1 0.4 0 0.4 0.4 145 5 146 305 1 0 1 0 -4 0 -3.8 -4.2 11/12/2004 10:00:00 8.9 0.4 9.9 7.2 8.7 0.4 9.9 7.6 0.4 0 0.4 0.4 138 3 142 305 1 0 1 0 -3.9 0.1 -3.3 -4 11/12/2004 10:10:00 8.9 0.4 9.9 7.6 8.9 0.4 9.9 7.6 0.4 0 0.4 0.4 135 2 136 305 1 0 1 0 -3.7 0.1 -3.1 -3.8 11/12/2004 10:20:00 9.3 0.5 10.7 7.6 9.3 0.5 10.7 7.6 0.4 0 0.4 0.4 133 3 134 305 1 0 1 0 -3.4 0.1 -2.7 -3.6 11/12/2004 10:30:00 9.7 0.4 10.7 8.4 9.6 0.5 10.7 8 0.4 0 0.4 0.4 136 3 136 305 1 0 1 0 -3.3 0 -2.7 -3.6 11/12/2004 10:40:00 9.4 0.5 10.7 8 9.3 0.6 10.7 7.6 0.4 0 0.4 0.4 137 3 142 305 1 0 1 0 -3.3 0 -2.7 -3.3 11/12/2004 10:50:00 9.6 0.7 11.5 7.6 9.4 0.6 11.1 7.2 0.4 0 0.4 0.4 137 4 140 305 1 0 1 0 -3.2 0 -2.7 -3.3 11/12/2004 11:00:00 9.6 0.6 11.1 8 9.4 0.6 10.7 7.6 0.4 0 0.4 0.4 137 4 135 305 1 0 1 0 -3.1 0 -2.7 -3.3 11/12/2004 11:10:00 9.9 0.7 11.5 8 9.7 0.7 11.5 8 0.4 0 0.4 0.4 138 5 138 305 1 0 1 0 -3.1 0 -2.7 -3.3 11/12/2004 11:20:00 9.8 0.8 11.5 7.6 9.6 0.7 11.8 8 0.4 0 0.4 0.4 138 5 138 305 1 0 1 0 -3 0 -2.4 -3.1 11/12/2004 11:30:00 9.8 0.8 11.8 7.6 9.6 0.7 11.5 7.6 0.4 0 0.4 0.4 139 5 139 305 1 0 1 0 -2.8 0 -2.4 -3.1 11/12/2004 11:40:00 9.9 0.9 12.6 7.6 9.7 0.8 12.6 7.6 0.4 0 0.4 0.4 140 6 138 305 1 0 1 0 -2.8 0 -2.4 -3.1 11/12/2004 11:50:00 9.9 1.2 13.3 7.2 9.8 1.2 13 6.8 0.4 0 0.4 0.4 143 7 154 305 1 0 0 0 -2.7 0.1 -2.4 -2.9 11/12/2004 12:00:00 10.1 1.1 12.6 7.2 9.9 1 12.2 7.6 0.4 0 0.4 0.4 140 7 150 305 1 0 0 0 -2.4 0 -1.8 -2.7 11/12/2004 12:10:00 9.8 1.2 13.3 7.2 9.7 1.1 13.3 7.2 0.4 0 0.4 0.4 143 8 150 305 1 0 0 0 -2.1 0.1 -1.5 -2.4 11/12/2004 12:20:00 10.4 1.2 14.5 8 10.2 1.1 13.7 7.6 0.4 0 0.4 0.4 143 9 138 305 1 0 1 0 -1.9 0 -1.5 -2.2 11/12/2004 12:30:00 10.6 0.9 12.6 7.6 10.4 0.8 13 8 0.4 0 0.4 0.4 135 5 136 305 1 0 1 0 -2 0 -2 -2 11/12/2004 12:40:00 9.3 1 11.8 6.5 9.1 0.9 11.1 6.5 0.4 0 0.4 0.4 137 8 137 305 0 0 0 0 -1.9 0 -1.3 -2 11/12/2004 12:50:00 8.3 1.2 11.5 4.9 8.3 1.2 11.5 5.3 0.4 0 0.4 0.4 139 9 134 305 0 0 0 0 -1.9 0 -1.5 -2 11/12/2004 13:00:00 7.6 1.1 10.7 3.8 7.6 1 9.9 5.3 0.4 0 0.4 0.4 147 11 150 305 0 0 1 0 -1.6 0.1 -1.1 -2 11/12/2004 13:10:00 8.5 1.3 11.8 4.6 8.4 1.2 11.8 4.9 0.4 0 0.4 0.4 140 10 147 305 0 0 0 0 -1.4 0 -0.8 -1.5 11/12/2004 13:20:00 8.6 1.1 11.1 5.3 8.5 1 11.1 5.3 0.4 0 0.4 0.4 137 8 144 305 0 0 0 0 -1.4 0 -1.1 -1.5 11/12/2004 13:30:00 9.2 1.2 12.2 6.1 9.1 1.2 12.2 6.1 0.4 0 0.4 0.4 137 7 150 305 0 0 0 0 -1.4 0 -1.3 -1.5 11/12/2004 13:40:00 9.5 1 12.2 6.8 9.4 1 12.2 7.2 0.4 0 0.4 0.4 137 7 141 305 0 0 0 0 -1.4 0 -1.1 -1.5 11/12/2004 13:50:00 9.3 1.3 13 5.3 9.3 1.3 13 6.1 0.4 0 0.4 0.4 137 9 158 305 0 0 0 0 -1.2 0 -1.1 -1.3 11/12/2004 14:00:00 9.3 1.3 12.6 4.6 9.3 1.3 12.2 5.3 0.4 0 0.4 0.4 137 8 136 305 0 0 0 0 -1.1 0 -0.8 -1.3 11/12/2004 14:10:00 9.8 1.2 11.8 5.7 9.7 1.2 12.2 6.1 0.4 0 0.4 0.4 135 8 124 305 0 0 0 0 -1.2 0 -1.1 -1.5 11/12/2004 14:20:00 9.7 1.3 13.3 4.9 9.5 1.2 12.6 6.5 0.4 0 0.4 0.4 137 10 161 305 0 0 0 0 -1.5 0.1 -1.1 -1.8 11/12/2004 14:30:00 9.1 1.4 12.6 5.3 9 1.2 11.8 5.7 0.4 0 0.4 0.4 143 11 151 305 0 0 0 0 -1.7 0 -1.5 -1.8 11/12/2004 14:40:00 10.5 1.4 14.5 7.2 10.6 1.3 14.5 7.2 0.4 0 0.4 0.4 138 9 127 305 0 0 0 0 -1.4 0 -1.1 -1.8 11/12/2004 14:50:00 10.2 1.7 13.7 6.1 10.1 1.6 14.1 6.8 0.4 0 0.4 0.4 140 10 149 305 0 0 0 0 -1.1 0 -0.8 -1.3 11/12/2004 15:00:00 10.7 1.7 14.9 5.7 10.4 1.6 14.9 5.7 0.4 0 0.4 0.4 137 9 144 305 0 0 0 0 -1 0.1 -0.6 -1.1 11/12/2004 15:10:00 8.6 1.4 11.8 5.3 8.5 1.2 11.8 5.3 0.4 0 0.4 0.4 145 14 144 305 0 0 0 0 -1.1 0 -1.1 -1.3 11/12/2004 15:20:00 8.6 1.5 13.3 5.3 8.6 1.3 12.2 5.7 0.4 0 0.4 0.4 148 12 138 305 0 0 0 0 -1.3 0 -1.1 -1.3 11/12/2004 15:30:00 8.7 1.7 13.7 4.2 8.6 1.5 12.2 5.3 0.4 0 0.4 0.4 150 13 162 305 0 0 0 0 -1.5 0 -1.1 -1.8 11/12/2004 15:40:00 8.4 1.6 13.3 3.4 8.4 1.3 12.6 3.8 0.4 0 0.4 0.4 142 13 133 305 0 0 0 0 -1.6 0 -1.3 -1.8 11/12/2004 15:50:00 8.5 1.7 12.6 4.9 8.6 1.5 12.2 5.3 0.4 0 0.4 0.4 144 13 158 305 0 0 0 0 -1.6 0 -1.3 -1.8 11/12/2004 16:00:00 7.7 1.5 11.5 4.2 8 1.5 12.2 4.6 0.4 0 0.4 0.4 148 15 143 305 1 0 1 0 -1.5 0 -1.1 -1.8 11/12/2004 16:10:00 8.5 1.8 13.7 4.6 8.7 1.5 13.3 5.3 0.4 0 0.4 0.4 150 13 161 305 1 0 1 0 -1.4 0 -1.1 -1.5 11/12/2004 16:20:00 10.5 1.9 15.3 5.7 10.4 1.7 14.5 6.1 0.4 0 0.4 0.4 148 11 146 305 1 0 1 0 -1.4 0 -0.8 -1.5 11/12/2004 16:30:00 11.1 1.8 15.6 6.5 11 1.5 15.3 7.2 0.4 0 0.4 0.4 149 11 149 305 1 0 1 0 -1.2 0 -0.6 -1.3 11/12/2004 16:40:00 12.3 1.9 17.2 8 12.1 1.7 16.4 8.8 0.4 0 0.4 0.4 148 10 150 305 1 0 1 0 -1.1 0 -0.6 -1.3 11/12/2004 16:50:00 11.3 1.6 16.4 6.1 11.2 1.5 16.1 7.6 0.4 0 0.4 0.4 149 10 143 305 1 0 1 0 -1.1 0 -0.6 -1.1 11/12/2004 17:00:00 11.3 1.7 15.3 7.2 11.1 1.7 15.6 6.8 0.4 0 0.4 0.4 146 11 144 305 1 0 1 0 -0.9 0 -0.6 -1.1 11/12/2004 17:10:00 11.5 1.7 16.1 6.8 11.2 1.7 15.6 6.8 0.4 0 0.4 0.4 139 11 128 305 1 0 1 0 -0.8 0 -0.6 -1.1 11/12/2004 17:20:00 13.4 1.3 16.8 8.8 13.2 1.3 16.4 9.5 0.4 0 0.4 0.4 135 7 131 305 1 0 1 0 -0.8 0 -0.4 -0.8 11/12/2004 17:30:00 13 1.3 16.1 9.5 12.7 1.3 16.1 8.4 0.4 0 0.4 0.4 134 6 131 305 1 0 1 0 -0.7 0 -0.1 -0.8 11/12/2004 17:40:00 12.7 1.4 16.1 8.4 12.3 1.3 16.1 8.8 0.4 0 0.4 0.4 136 8 132 305 1 0 1 0 -0.7 0 -0.1 -0.8 11/12/2004 17:50:00 12 1.5 16.4 7.6 11.8 1.4 15.6 7.6 0.4 0 0.4 0.4 134 9 135 305 1 0 1 0 -0.6 0 -0.6 -0.6 11/12/2004 18:00:00 11.7 2.1 16.8 6.1 11.4 2 16.8 5.7 0.4 0 0.4 0.4 134 11 149 305 1 0 1 0 -0.6 0 -0.4 -0.6 11/12/2004 18:10:00 12.3 1.8 16.4 7.6 11.9 1.7 16.1 7.6 0.4 0 0.4 0.4 135 10 130 305 1 0 1 0 -0.6 0 -0.1 -0.6 11/12/2004 18:20:00 12.6 1.6 16.1 7.6 12.3 1.6 16.8 8 0.4 0 0.4 0.4 136 8 138 305 1 0 1 0 -0.5 0 -0.4 -0.6 11/12/2004 18:30:00 12.7 1.7 16.8 8 12.3 1.6 16.1 7.2 0.4 0 0.4 0.4 136 8 131 305 1 0 1 0 -0.5 0 -0.4 -0.6 11/12/2004 18:40:00 12.8 1.5 16.4 8.4 12.4 1.4 15.6 8.8 0.4 0 0.4 0.4 137 9 151 305 1 0 1 0 -0.5 0 0.1 -0.6 11/12/2004 18:50:00 12.3 1.6 16.1 7.6 12.2 1.5 16.4 8.4 0.4 0 0.4 0.4 136 9 132 305 1 0 1 0 -0.4 0 0.1 -0.6 11/12/2004 19:00:00 12.4 2.2 17.2 6.5 12.2 2.2 17.6 6.1 0.4 0 0.4 0.4 138 11 130 305 1 0 1 0 -0.4 0 0.1 -0.4 11/12/2004 19:10:00 11.2 1.7 16.4 6.1 11 1.6 14.9 6.8 0.4 0 0.4 0.4 142 13 147 305 1 0 1 0 -0.4 0 0.1 -0.4 11/12/2004 19:20:00 11.8 2.3 17.2 6.1 11.6 2 17.2 6.8 0.4 0 0.4 0.4 146 10 141 305 1 0 1 0 -0.4 0 -0.1 -0.4 11/12/2004 19:30:00 12.2 1.8 16.8 7.6 11.9 1.6 16.1 6.8 0.4 0 0.4 0.4 147 12 156 305 1 0 1 0 -0.3 0 0.1 -0.4 11/12/2004 19:40:00 11.8 1.7 16.8 7.6 11.5 1.7 16.1 7.6 0.4 0 0.4 0.4 145 11 145 305 1 0 1 0 -0.3 0 0.3 -0.4 11/12/2004 19:50:00 12.8 2 18.7 8.8 12.5 2 17.9 8 0.4 0 0.4 0.4 144 12 148 305 1 0 1 0 -0.4 0 -0.1 -0.6 11/12/2004 20:00:00 12.9 2 17.6 6.8 12.9 1.9 18.3 7.6 0.4 0 0.4 0.4 139 11 139 305 1 0 1 0 -0.4 0.1 0.1 -0.6 11/12/2004 20:10:00 12.8 1.8 17.9 8 12.6 1.7 17.9 7.2 0.4 0 0.4 0.4 139 11 147 305 1 0 1 0 -0.5 0 0.1 -0.6 11/12/2004 20:20:00 11.9 2 16.4 6.5 11.7 1.8 16.1 7.6 0.4 0 0.4 0.4 140 12 141 305 1 0 1 0 -0.6 0 -0.4 -0.6 11/12/2004 20:30:00 11.5 2.1 16.4 6.8 11.4 2 15.6 5.7 0.4 0 0.4 0.4 139 12 152 305 1 0 1 0 -0.5 0 -0.4 -0.6 11/12/2004 20:40:00 11.5 1.7 16.1 7.6 11.4 1.8 15.6 7.2 0.4 0 0.4 0.4 142 13 142 305 1 0 1 0 -0.5 0 0.1 -0.6 11/12/2004 20:50:00 11.9 1.8 16.4 7.2 11.9 1.8 16.8 6.5 0.4 0 0.4 0.4 141 13 152 305 1 0 1 0 -0.5 0 -0.4 -0.6 11/12/2004 21:00:00 12.3 2.2 17.9 7.2 12.2 2.1 17.2 7.6 0.4 0 0.4 0.4 138 11 136 305 2 0 2 0 -0.5 0 -0.4 -0.6 11/12/2004 21:10:00 12.3 2.4 17.9 5.7 12.2 2.1 17.2 6.8 0.4 0 0.4 0.4 138 13 137 305 2 0 2 0 -0.6 0 -0.4 -0.6 11/12/2004 21:20:00 12.5 2.4 18.7 7.2 12.3 2.3 18.3 6.5 0.4 0 0.4 0.4 137 11 144 305 2 0 1 0 -0.6 0 -0.6 -0.6 11/12/2004 21:30:00 12.6 1.9 17.2 7.2 12.6 1.8 17.2 6.8 0.4 0 0.4 0.4 137 11 133 305 2 0 2 0 -0.7 0 -0.1 -0.8 11/12/2004 21:40:00 12.9 1.7 17.9 8.4 12.8 1.8 17.6 8 0.4 0 0.4 0.4 137 11 131 305 2 0 2 0 -0.8 0 -0.6 -1.1 11/12/2004 21:50:00 13.7 1.9 18.3 8.8 13.6 1.8 17.6 8.8 0.4 0 0.4 0.4 137 9 134 305 3 0 2 0 -0.8 0 -0.4 -0.8 11/12/2004 22:00:00 13.4 2 18.7 6.8 13.2 1.8 19.1 8 0.4 0 0.4 0.4 138 10 125 305 3 0 3 0 -0.7 0 -0.6 -0.8 11/12/2004 22:10:00 12.3 2 17.6 7.2 12.2 1.8 16.4 8 0.4 0 0.4 0.4 139 12 142 305 3 0 3 0 -0.7 0 -0.6 -0.8 11/12/2004 22:20:00 13.1 2.1 18.7 6.8 12.8 2 19.5 8.8 0.4 0 0.4 0.4 137 12 147 305 3 0 3 0 -0.7 0 -0.6 -0.8 11/12/2004 22:30:00 13 2.1 17.9 8.4 12.9 2 18.3 8.4 0.4 0 0.4 0.4 137 13 148 305 3 0 4 0 -0.7 0 -0.6 -0.8 11/12/2004 22:40:00 14.5 1.9 19.5 8.8 14.2 1.9 19.1 8.4 0.4 0 0.4 0.4 136 9 135 305 4 0 4 0 -0.7 0 -0.6 -0.8 11/12/2004 22:50:00 13.7 2.3 19.5 8.4 13.3 2.2 18.7 7.2 0.4 0 0.4 0.4 137 12 110 305 4 0 4 0 -0.7 0 -0.6 -0.8 11/12/2004 23:00:00 13.4 2.2 19.1 7.6 13.2 2.3 19.5 8 0.4 0 0.4 0.4 138 10 126 305 4 0 4 0 -0.6 0 0.1 -0.6 11/12/2004 23:10:00 13.3 2.1 18.7 8 13.1 2 18.3 8.4 0.4 0 0.4 0.4 139 12 134 305 4 0 4 0 -0.6 0 -0.4 -0.6 11/12/2004 23:20:00 14.5 2.1 20.6 9.5 14 2.1 19.5 8.8 0.4 0 0.4 0.4 138 11 133 305 4 0 4 0 -0.6 0 -0.6 -0.6 11/12/2004 23:30:00 14.3 2.1 19.1 9.1 14.1 2.1 19.9 9.9 0.4 0 0.4 0.4 138 11 129 305 4 0 4 0 -0.6 0 -0.4 -0.6 11/12/2004 23:40:00 14.1 2 19.5 8 13.8 1.9 19.5 8.8 0.4 0 0.4 0.4 139 12 128 305 4 0 5 0 -0.5 0 -0.4 -0.6 11/12/2004 23:50:00 14.6 2.4 20.2 8.8 14.1 2.4 21.8 8.8 0.4 0 0.4 0.4 138 11 124 305 5 0 5 0 -0.5 0 -0.4 -0.6 11/13/2004 00:00:00 14.5 2.4 20.6 7.2 14.1 2.3 21.8 7.6 0.4 0 0.4 0.4 139 11 148 305 5 0 5 0 -0.4 0.1 0.1 -0.6 11/13/2004 00:10:00 14.6 2.2 20.2 8.8 14.3 2.1 19.1 8.4 0.4 0 0.4 0.4 139 12 138 305 5 0 5 0 -0.4 0.1 0.1 -0.6 11/13/2004 00:20:00 14.6 2.5 21.4 8.8 14.3 2.4 22.1 9.1 0.4 0 0.4 0.4 139 11 136 305 5 0 5 0 -0.4 0 0.1 -0.6 11/13/2004 00:30:00 13.9 2.3 19.5 8.4 13.5 2.1 19.1 8 0.4 0 0.4 0.4 142 13 139 305 5 0 5 0 -0.4 0.1 0.1 -0.4 11/13/2004 00:40:00 13.6 2.2 19.9 8.4 13.3 2.1 19.1 8.8 0.4 0 0.4 0.4 141 12 133 305 5 0 5 0 -0.4 0 0.1 -0.4 11/13/2004 00:50:00 14.2 2.2 20.2 9.5 13.8 2.2 19.9 8.4 0.4 0 0.4 0.4 141 12 137 305 5 0 5 0 -0.4 0 0.1 -0.4 11/13/2004 01:00:00 13.4 2 19.1 8 13 1.9 20.2 7.6 0.4 0 0.4 0.4 139 13 132 305 5 0 5 0 -0.3 0 0.1 -0.4 11/13/2004 01:10:00 13.7 2.2 20.6 8.8 13.4 2.1 20.6 8.8 0.4 0 0.4 0.4 141 12 160 305 5 0 5 0 -0.3 0 0.3 -0.4 11/13/2004 01:20:00 13.1 2.1 18.3 8 12.7 2 18.7 8.8 0.4 0 0.4 0.4 144 12 147 305 5 0 5 0 -0.3 0 0.1 -0.4 11/13/2004 01:30:00 13.4 2.1 18.7 8.4 13 2 18.7 8.8 0.4 0 0.4 0.4 142 12 147 305 5 0 5 0 -0.3 0 0.3 -0.4 11/13/2004 01:40:00 13.2 2.2 17.9 7.2 13 2 17.6 8 0.4 0 0.4 0.4 146 11 144 305 5 0 5 0 -0.2 0 0.3 -0.4 11/13/2004 01:50:00 13.4 2.4 19.1 6.8 13.2 2.1 17.9 6.8 0.4 0 0.4 0.4 149 13 158 305 5 0 5 0 -0.1 0 0.3 -0.4 11/13/2004 02:00:00 11.3 2.6 17.9 5.3 11.5 2.1 17.2 7.2 0.4 0 0.4 0.4 152 14 122 305 5 0 5 0 -0.1 0 0.3 -0.1 11/13/2004 02:10:00 10.3 2.1 17.9 5.3 10.7 1.7 17.2 6.5 0.4 0 0.4 0.4 157 17 147 305 5 0 5 0 0 0 0.6 -0.1 11/13/2004 02:20:00 11.9 2.5 19.1 7.2 12.2 2.1 17.9 8 0.4 0 0.4 0.4 154 15 150 305 5 0 5 0 0 0.1 0.6 0.1 11/13/2004 02:30:00 13.5 2.6 19.9 7.6 13.5 2.3 19.1 7.6 0.4 0 0.4 0.4 153 13 150 305 5 0 6 0 0.2 0 0.6 0.1 11/13/2004 02:40:00 12.8 1.9 18.7 8.4 14.4 1.9 19.9 9.5 0.4 0 0.4 0.4 175 17 166 305 5 0 5 0 0.2 0 0.6 -0.1 11/13/2004 02:50:00 10 1.6 13.7 6.1 9.4 1.7 13.3 6.1 0.4 0 0.4 0.4 220 8 208 305 4 0 5 0 -0.1 0 0.3 -0.4 11/13/2004 03:00:00 8.2 1.1 10.3 5.7 7.6 1 9.5 5.3 0.4 0 0.4 0.4 224 4 227 305 4 0 5 0 -0.4 0 -0.4 -0.6 11/13/2004 03:10:00 7.3 0.6 8.8 5.3 7 0.7 8.4 4.9 0.4 0 0.4 0.4 214 3 213 305 5 0 5 0 -0.5 0 -0.1 -0.6 11/13/2004 03:20:00 6.4 0.6 8 5.3 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.6 0 0.1 -0.6 11/13/2004 03:30:00 5.5 0.4 6.5 4.6 5.4 0.5 6.8 4.2 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.7 0 -0.6 -0.8 11/13/2004 03:40:00 5.6 0.4 6.5 4.9 5.5 0.4 6.5 4.2 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.9 0 -0.6 -1.1 11/13/2004 03:50:00 5.4 0.7 6.8 3.8 5.3 0.7 6.5 3.8 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.9 0 -0.6 -1.1 11/13/2004 04:00:00 5.4 0.4 6.5 3.8 5.3 0.5 6.5 3.8 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -1.1 0 -0.6 -1.1 11/13/2004 04:10:00 6.3 0.6 7.6 4.9 6.3 0.6 8 4.6 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -1.1 0 -0.6 -1.3 11/13/2004 04:20:00 7.3 0.3 8 6.1 7.4 0.4 8 6.1 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -1.2 0 -0.6 -1.5 11/13/2004 04:30:00 7.6 0.4 8.8 6.8 7.8 0.3 8.8 6.8 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -1.4 0 -1.1 -1.5 11/13/2004 04:40:00 8.2 0.5 9.9 6.8 8.2 0.4 9.1 6.5 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -1.4 0 -0.8 -1.5 11/13/2004 04:50:00 9 0.4 9.9 8.4 9 0.3 9.9 8 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -1.6 0.1 -1.1 -1.8 11/13/2004 05:00:00 9.4 0.4 10.3 8.4 9.4 0.3 10.3 8.4 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -1.5 0.1 -1.1 -1.8 11/13/2004 05:10:00 9.3 0.4 10.7 8.4 9.4 0.4 10.3 7.6 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -1.6 0 -1.3 -1.8 11/13/2004 05:20:00 8.9 0.6 10.3 6.8 8.9 0.7 10.3 6.1 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -1.4 0 -1.1 -1.8 11/13/2004 05:30:00 9.5 0.9 12.2 7.6 9.1 0.8 11.5 6.8 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -1 0.1 -0.6 -1.3 11/13/2004 05:40:00 9.5 0.7 11.1 7.6 8.7 0.8 10.7 6.5 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.7 0 -0.6 -0.8 11/13/2004 05:50:00 9.8 0.9 11.8 8 8.9 0.9 11.1 6.8 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.7 0 -0.4 -0.8 11/13/2004 06:00:00 9.7 0.7 11.5 8.4 9 0.8 11.1 6.8 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.5 0 -0.4 -0.6 11/13/2004 06:10:00 9.9 0.6 11.8 8.4 9.2 0.7 10.7 6.8 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.4 0 -0.1 -0.6 11/13/2004 06:20:00 10.2 0.8 11.8 7.2 9.1 0.9 11.5 6.8 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.5 0 -0.4 -0.6 11/13/2004 06:30:00 9.7 0.7 11.1 6.5 8.9 0.8 10.7 6.1 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.7 0 -0.6 -0.8 11/13/2004 06:40:00 9.5 0.8 11.5 7.2 8.8 0.8 11.5 6.1 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.7 0 -0.6 -0.8 11/13/2004 06:50:00 9.2 0.6 10.7 7.2 8.7 0.6 9.9 6.8 0.4 0 0.4 0.4 213 0 213 305 5 0 5 0 -0.7 0 -0.4 -0.8 11/13/2004 07:00:00 8 1.2 10.7 5.7 7.7 1 9.5 5.7 0.4 0 0.4 0.4 201 14 213 305 5 0 5 0 -1 0.3 -0.6 -1.5 11/13/2004 07:10:00 7.7 1.2 10.7 4.2 7.2 1 9.5 4.6 0.4 0 0.4 0.4 207 11 222 305 5 0 5 0 -1.4 0.1 -1.1 -1.8 11/13/2004 07:20:00 9 0.5 10.3 7.2 8.3 0.7 9.9 6.1 0.4 0 0.4 0.4 214 3 214 305 5 0 5 0 -0.8 0 -0.4 -1.1 11/13/2004 07:30:00 9.7 0.8 11.1 7.6 8.7 0.9 11.1 6.5 0.4 0 0.4 0.4 216 5 213 305 5 0 5 0 -0.6 0 -0.4 -0.8 11/13/2004 07:40:00 10 0.9 12.6 7.6 9.2 0.9 11.8 6.8 0.4 0 0.4 0.4 220 4 220 305 5 0 5 0 -0.5 0 0.1 -0.6 11/13/2004 07:50:00 11.4 1.3 14.5 8.4 10.5 1.4 13.7 6.8 0.4 0 0.4 0.4 213 5 211 305 5 0 5 0 -0.4 0 0.1 -0.6 11/13/2004 08:00:00 10.1 1.8 13 5.3 9.3 1.8 12.6 5.3 0.4 0 0.4 0.4 220 13 205 305 5 0 5 0 -0.6 0 0.1 -1.1 11/13/2004 08:10:00 8 0.5 9.1 5.7 7.4 0.6 8.8 4.9 0.4 0 0.4 0.4 233 4 227 305 5 0 5 0 -0.9 0 -0.4 -1.1 11/13/2004 08:20:00 7.8 0.9 11.1 5.7 7.1 0.9 9.9 4.9 0.4 0 0.4 0.4 225 5 218 305 5 0 4 0 -0.9 0.1 -0.4 -1.1 11/13/2004 08:30:00 10.7 0.9 12.6 8 9.6 1 12.2 7.2 0.4 0 0.4 0.4 225 5 214 305 5 0 5 0 -0.5 0 0.1 -1.1 11/13/2004 08:40:00 10.9 1.2 13 7.2 9.9 1.3 12.6 6.5 0.4 0 0.4 0.4 225 5 231 305 5 0 5 0 -0.5 0.1 0.1 -0.6 11/13/2004 08:50:00 10.1 0.9 12.2 8 9.2 0.9 12.2 6.8 0.4 0 0.4 0.4 222 5 220 305 5 0 5 0 -0.6 0 0.1 -0.8 11/13/2004 09:00:00 11.5 1.1 15.3 8 10.6 1.1 13 7.6 0.4 0 0.4 0.4 230 6 229 305 4 0 5 0 -0.6 0 0.1 -0.6 11/13/2004 09:10:00 12.3 1.2 14.9 8.8 11.1 1.2 13.3 7.2 0.4 0 0.4 0.4 227 5 231 305 4 0 4 0 -0.8 0.1 -0.4 -1.1 11/13/2004 09:20:00 11.3 1 13.3 8.4 10.5 1.1 13 7.2 0.4 0 0.4 0.4 229 4 227 305 4 0 4 0 -1.1 0 -0.6 -1.1 11/13/2004 09:30:00 10.7 1.1 13.3 8 9.8 1.2 12.2 6.8 0.4 0 0.4 0.4 228 4 231 305 4 0 4 0 -1.1 0 -0.8 -1.1 11/13/2004 09:40:00 11 1 13.3 8 10.1 1.1 12.6 7.2 0.4 0 0.4 0.4 224 4 224 305 4 0 4 0 -1.1 0 -0.8 -1.1 11/13/2004 09:50:00 10.2 0.8 12.2 8 9.5 0.9 11.8 7.6 0.4 0 0.4 0.4 220 4 217 305 4 0 4 0 -1.1 0 -1.1 -1.3 11/13/2004 10:00:00 10.7 0.8 12.6 8.8 9.8 1 12.2 7.2 0.4 0 0.4 0.4 215 4 209 305 4 0 4 0 -0.9 0 -0.4 -1.1 11/13/2004 10:10:00 11.3 1 13.3 8.4 10.6 1.1 13 7.6 0.4 0 0.4 0.4 221 5 218 305 4 0 4 0 -0.6 0 -0.4 -0.8 11/13/2004 10:20:00 11 1.7 15.6 8 10 1.7 14.1 6.8 0.4 0 0.4 0.4 228 5 223 305 4 0 4 0 -1 0.2 -0.4 -1.3 11/13/2004 10:30:00 9.5 0.8 11.1 6.8 8.6 0.8 10.7 6.5 0.4 0 0.4 0.4 224 4 231 305 4 0 4 0 -1.2 0 -1.1 -1.3 11/13/2004 10:40:00 8.9 0.8 10.7 6.5 8.3 0.8 10.3 6.1 0.4 0 0.4 0.4 221 4 221 305 4 0 4 0 -1.2 0 -0.8 -1.3 11/13/2004 10:50:00 9.6 0.9 11.8 6.8 8.8 0.9 11.1 6.5 0.4 0 0.4 0.4 224 5 220 305 4 0 4 0 -1.1 0 -0.6 -1.1 11/13/2004 11:00:00 10.1 0.7 11.8 8 9.2 0.9 11.1 6.5 0.4 0 0.4 0.4 225 4 231 305 4 0 4 0 -1 0 -0.6 -1.1 11/13/2004 11:10:00 10.5 1 13.3 7.2 9.5 1 12.6 6.5 0.4 0 0.4 0.4 223 5 225 305 3 0 4 0 -1 0 -0.8 -1.1 11/13/2004 11:20:00 11.1 0.9 13 8.8 10.4 1 12.6 7.2 0.4 0 0.4 0.4 218 4 217 305 3 0 3 0 -1.1 0 -0.6 -1.1 11/13/2004 11:30:00 10.2 0.9 12.2 7.6 9.5 0.9 11.5 7.2 0.4 0 0.4 0.4 220 5 224 305 3 0 3 0 -1.1 0 -0.6 -1.3 11/13/2004 11:40:00 10.5 0.9 12.6 7.6 10 1 12.6 7.2 0.4 0 0.4 0.4 218 4 217 305 3 0 3 0 -1 0 -0.4 -1.1 11/13/2004 11:50:00 10 0.8 11.8 7.6 9.4 1 11.8 6.8 0.4 0 0.4 0.4 221 6 218 305 3 0 2 0 -0.8 0 -0.6 -1.1 11/13/2004 12:00:00 11.9 1.2 14.9 8 10.8 1.3 13.7 7.2 0.4 0 0.4 0.4 229 6 234 305 2 0 2 0 -1.7 0.4 -0.6 -2.2 11/13/2004 12:10:00 10 1.3 12.6 6.5 9.2 1.1 11.8 6.5 0.4 0 0.4 0.4 214 7 217 305 2 0 2 0 -2.2 0 -2 -2.4 11/13/2004 12:20:00 8.2 0.6 9.5 6.8 7.7 0.8 9.1 5.3 0.4 0 0.4 0.4 211 5 214 305 2 0 2 0 -1.9 0 -1.8 -2 11/13/2004 12:30:00 7.4 0.6 8.8 6.1 7.1 0.6 8.8 4.9 0.4 0 0.4 0.4 208 2 208 305 2 0 2 0 -1.7 0 -1.5 -2 11/13/2004 12:40:00 7.9 1.5 11.5 5.7 7.2 1.3 10.7 4.6 0.4 0 0.4 0.4 217 9 236 305 2 0 2 0 -1.2 0.2 -0.6 -1.8 11/13/2004 12:50:00 10.2 0.9 12.2 7.6 9.1 0.9 11.5 6.1 0.4 0 0.4 0.4 224 4 228 305 2 0 2 0 -0.8 0 -0.6 -1.1 11/13/2004 13:00:00 9.8 0.8 11.5 7.6 8.7 0.9 11.1 6.5 0.4 0 0.4 0.4 224 4 224 305 2 0 2 0 -0.8 0 -0.4 -0.8 11/13/2004 13:10:00 9.3 0.9 11.1 6.5 8.3 1 10.7 6.1 0.4 0 0.4 0.4 224 5 225 305 2 0 1 0 -0.7 0 -0.4 -0.8 11/13/2004 13:20:00 8.4 1.1 11.1 4.9 7.4 1.1 10.3 4.6 0.4 0 0.4 0.4 226 5 220 305 1 0 1 0 -0.7 0 -0.4 -0.6 11/13/2004 13:30:00 8.1 0.7 9.5 5.3 7.3 0.9 9.1 4.9 0.4 0 0.4 0.4 228 3 230 305 1 0 1 0 -0.7 0 -0.6 -0.6 11/13/2004 13:40:00 6.9 0.9 9.5 4.9 6 0.9 8.8 3.8 0.4 0 0.4 0.4 231 5 234 305 1 0 1 0 -0.6 0 -0.4 -0.6 11/13/2004 13:50:00 7.7 0.8 9.1 5.3 6.9 0.8 8.8 4.9 0.4 0 0.4 0.4 236 5 236 305 1 0 1 0 -0.8 0.1 -0.6 -1.1 11/13/2004 14:00:00 6.3 0.5 7.2 4.6 5.8 0.6 6.8 4.2 0.4 0 0.4 0.4 227 5 231 305 1 0 1 0 -0.9 0 -0.6 -1.1 11/13/2004 14:10:00 6.5 0.5 8 4.9 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 216 3 217 305 1 0 1 0 -0.8 0 -0.6 -1.1 11/13/2004 14:20:00 6.3 0.5 8 4.6 5.8 0.6 7.2 4.2 0.4 0 0.4 0.4 218 5 219 305 1 0 1 0 -0.7 0 -0.6 -0.8 11/13/2004 14:30:00 6.8 0.8 8.8 4.9 6.3 0.8 8 4.6 0.4 0 0.4 0.4 225 4 223 305 1 0 1 0 -0.5 0 -0.4 -0.6 11/13/2004 14:40:00 7.4 0.7 9.1 4.9 6.8 0.8 8.4 4.6 0.4 0 0.4 0.4 228 4 232 305 1 0 1 0 -0.5 0 -0.4 -0.6 11/13/2004 14:50:00 7.7 0.7 9.1 5.7 6.9 0.9 8.8 4.9 0.4 0 0.4 0.4 226 5 226 305 1 0 1 0 -0.5 0 -0.1 -0.6 11/13/2004 15:00:00 8 0.7 9.5 5.7 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 224 5 219 305 1 0 1 0 -0.5 0 -0.1 -0.6 11/13/2004 15:10:00 7.5 0.6 8.8 5.7 7 0.7 8.4 5.3 0.4 0 0.4 0.4 220 4 222 305 1 0 1 0 -0.6 0 -0.4 -0.6 11/13/2004 15:20:00 7.1 0.5 8 5.3 6.7 0.6 8 4.6 0.4 0 0.4 0.4 214 3 213 305 1 0 1 0 -0.7 0 -0.6 -0.8 11/13/2004 15:30:00 6.1 1 8.4 3.4 5.6 1 8 3.4 0.4 0 0.4 0.4 217 9 213 305 1 0 1 0 -0.7 0 -0.6 -0.8 11/13/2004 15:40:00 4.2 0.8 5.7 2.3 3.9 0.8 5.7 2.3 0.4 0 0.4 0.4 231 7 229 305 1 0 0 0 -0.7 0 -0.6 -1.1 11/13/2004 15:50:00 4.8 0.5 6.1 3.4 4.5 0.5 5.7 3 0.4 0 0.4 0.4 222 4 227 305 1 0 1 0 -0.7 0 -0.6 -0.8 11/13/2004 16:00:00 5.3 0.5 6.5 3 5.1 0.6 6.5 3.4 0.4 0 0.4 0.4 211 4 210 305 1 0 1 0 -0.7 0 -0.6 -0.8 11/13/2004 16:10:00 4.2 0.4 5.3 3 4 0.5 5.3 2.3 0.4 0 0.4 0.4 212 3 215 305 1 0 1 0 -0.9 0.1 -0.6 -1.1 11/13/2004 16:20:00 3.4 0.6 4.6 2.3 3.6 0.5 4.6 2.3 0.4 0 0.4 0.4 202 8 210 305 1 0 1 0 -1 0 -0.6 -1.3 11/13/2004 16:30:00 2.9 0.3 3.4 2.3 3.2 0.3 3.8 2.6 0.4 0 0.4 0.4 195 4 190 305 1 0 1 0 -1.4 0 -1.1 -1.5 11/13/2004 16:40:00 2.2 0.4 3 0.7 2.8 0.2 3.4 1.9 0.4 0 0.4 0.4 184 4 188 305 1 0 1 0 -1.8 0.1 -1.3 -2 11/13/2004 16:50:00 1.1 0.4 1.9 0.4 2.7 0.4 3.4 1.9 0.4 0 0.4 0.4 172 5 179 305 1 0 1 0 -2.2 0 -1.5 -2.4 11/13/2004 17:00:00 2.9 0.7 4.2 1.1 3.8 0.3 4.6 3 0.4 0 0.4 0.4 156 8 155 305 1 0 1 0 -2.4 0 -2.2 -2.7 11/13/2004 17:10:00 3.1 0.2 3.4 2.3 3.8 0.2 4.2 3.4 0.4 0 0.4 0.4 148 5 152 305 1 0 1 0 -2.5 0 -2.2 -2.7 11/13/2004 17:20:00 3.1 0.2 3.4 2.6 3.6 0.2 4.2 3.4 0.4 0 0.4 0.4 142 0 142 305 1 0 1 0 -2.4 0 -2.2 -2.7 11/13/2004 17:30:00 3 0.1 3.4 2.6 3.4 0.2 3.8 3 0.4 0 0.4 0.4 139 3 143 305 1 0 1 0 -2.2 0 -2 -2.4 11/13/2004 17:40:00 3 0.2 3.4 2.6 3.4 0.2 3.8 3 0.4 0 0.4 0.4 134 1 136 305 1 0 1 0 -2.1 0 -2 -2.2 11/13/2004 17:50:00 3.2 0.2 3.8 3 3.7 0.2 4.2 3.4 0.4 0 0.4 0.4 135 1 136 305 1 0 1 0 -2 0 -1.8 -2 11/13/2004 18:00:00 4 0.7 5.7 2.6 4.2 0.6 5.3 3 0.4 0 0.4 0.4 127 5 128 305 2 0 2 0 -1.9 0 -1.3 -2 11/13/2004 18:10:00 4 0.5 5.3 3 4.2 0.4 5.3 3 0.4 0 0.4 0.4 126 5 126 305 2 0 1 0 -1.8 0 -1.8 -2 11/13/2004 18:20:00 3.8 0.4 4.9 2.3 3.9 0.4 4.9 2.6 0.4 0 0.4 0.4 119 6 127 305 2 0 2 0 -1.6 0 -1.3 -1.8 11/13/2004 18:30:00 3.9 0.4 4.9 2.6 4 0.4 4.9 2.6 0.4 0 0.4 0.4 115 4 116 305 2 0 2 0 -1.4 0 -1.3 -1.5 11/13/2004 18:40:00 4.4 0.5 5.7 3 4.5 0.5 5.3 3.4 0.4 0 0.4 0.4 120 6 118 305 2 0 2 0 -1.4 0 -1.3 -1.5 11/13/2004 18:50:00 3.9 0.5 4.9 2.6 4 0.4 5.3 3 0.4 0 0.4 0.4 117 8 121 305 2 0 2 0 -1.2 0 -1.1 -1.3 11/13/2004 19:00:00 3.2 0.7 4.6 1.1 3.3 0.7 4.9 1.1 0.4 0 0.4 0.4 117 9 118 305 2 0 2 0 -1.1 0 -0.6 -1.3 11/13/2004 19:10:00 2.3 0.5 3.8 1.1 2.5 0.4 3.8 1.5 0.4 0 0.4 0.4 111 7 103 305 3 0 3 0 -1.2 0 -0.8 -1.3 11/13/2004 19:20:00 2.5 0.6 3.8 0.4 2.6 0.6 4.2 1.1 0.4 0 0.4 0.4 97 11 111 305 3 0 3 0 -1.1 0 -0.6 -1.3 11/13/2004 19:30:00 3.4 0.6 5.3 1.9 3.4 0.6 6.1 2.3 0.4 0 0.4 0.4 78 13 76 305 3 0 3 0 -1 0 -0.8 -1.1 11/13/2004 19:40:00 4.5 0.6 6.1 2.6 4.4 0.5 5.3 2.6 0.4 0 0.4 0.4 73 7 79 305 3 0 3 0 -0.8 0 -0.4 -1.1 11/13/2004 19:50:00 4.6 0.3 5.3 3.8 4.5 0.3 5.7 3.8 0.4 0 0.4 0.4 77 4 74 305 3 0 3 0 -0.9 0 -0.6 -1.1 11/13/2004 20:00:00 4.9 0.4 5.7 3.8 4.7 0.4 5.7 3.8 0.4 0 0.4 0.4 77 4 75 305 3 0 3 0 -1 0 -0.6 -1.1 11/13/2004 20:10:00 4.3 0.5 5.3 2.6 4.1 0.5 5.3 2.6 0.4 0 0.4 0.4 76 6 81 305 3 0 3 0 -1 0 -0.6 -1.1 11/13/2004 20:20:00 4.5 0.5 5.7 3.4 4.4 0.5 5.7 3 0.4 0 0.4 0.4 76 5 78 305 3 0 3 0 -1 0 -0.6 -1.1 11/13/2004 20:30:00 5.1 0.6 6.5 3.8 4.9 0.7 6.8 3.4 0.4 0 0.4 0.4 70 7 64 305 3 0 4 0 -0.8 0 -0.4 -1.1 11/13/2004 20:40:00 5.7 0.8 8 3.8 5.5 0.8 8 3.8 0.4 0 0.4 0.4 75 8 67 305 4 0 4 0 -0.6 0 -0.4 -0.6 11/13/2004 20:50:00 6 0.9 7.6 3.4 5.7 0.8 8.4 3.4 0.4 0 0.4 0.4 79 10 65 305 4 0 4 0 -0.7 0 -0.4 -0.8 11/13/2004 21:00:00 6.6 1.1 9.1 3 6.3 1.1 9.1 3 0.4 0 0.4 0.4 82 11 80 305 4 0 4 0 -1.1 0 -0.6 -1.3 11/13/2004 21:10:00 6.3 1.2 9.5 3 6.1 1.1 9.5 3.4 0.4 0 0.4 0.4 79 10 67 305 4 0 4 0 -1.4 0 -1.3 -1.5 11/13/2004 21:20:00 7.1 0.9 9.9 5.3 6.9 0.8 9.9 4.9 0.4 0 0.4 0.4 83 9 70 305 4 0 4 0 -1.6 0 -1.3 -1.8 11/13/2004 21:30:00 7 0.8 8.8 4.9 6.6 0.9 8.8 4.2 0.4 0 0.4 0.4 81 7 78 305 4 0 4 0 -1.6 0 -1.5 -1.8 11/13/2004 21:40:00 7.9 0.5 9.1 6.5 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 71 5 77 305 4 0 4 0 -1.7 0 -1.8 -1.8 11/13/2004 21:50:00 8.4 0.5 9.1 6.8 8.3 0.5 9.5 6.8 0.4 0 0.4 0.4 66 3 68 305 4 0 4 0 -1.7 0 -1.3 -1.8 11/13/2004 22:00:00 8.6 0.7 9.9 6.8 8.5 0.7 9.9 6.5 0.4 0 0.4 0.4 62 4 63 305 4 0 4 0 -1.7 0 -1.3 -1.8 11/13/2004 22:10:00 9.2 0.8 11.1 7.2 9.1 0.9 10.7 6.8 0.4 0 0.4 0.4 59 4 62 305 4 0 4 0 -1.7 0 -1.3 -2 11/13/2004 22:20:00 9.4 0.6 11.1 8 9.5 0.7 11.5 7.6 0.4 0 0.4 0.4 57 3 53 305 4 0 5 0 -1.8 0 -1.8 -2 11/13/2004 22:30:00 9.9 0.5 11.5 8.4 9.8 0.6 11.1 7.6 0.4 0 0.4 0.4 52 4 57 305 5 0 5 0 -1.7 0 -1.5 -1.8 11/13/2004 22:40:00 9.6 0.6 10.7 8 9.6 0.8 11.1 7.2 0.4 0 0.4 0.4 50 5 45 305 5 0 5 0 -1.6 0 -1.3 -1.8 11/13/2004 22:50:00 10.4 0.9 13 8.4 10.4 1 13.3 8.4 0.4 0 0.4 0.4 48 4 47 305 5 0 5 0 -1.4 0 -1.3 -1.5 11/13/2004 23:00:00 11.2 0.8 13 9.1 11.1 0.9 13.3 8.4 0.4 0 0.4 0.4 49 4 53 305 5 0 5 0 -1.2 0 -0.8 -1.3 11/13/2004 23:10:00 12.2 1 15.3 10.3 12 1 14.9 9.5 0.4 0 0.4 0.4 50 4 46 305 6 0 6 0 -1.1 0 -1.1 -1.3 11/13/2004 23:20:00 12.4 0.8 14.1 10.3 12.2 1 14.1 8.8 0.4 0 0.4 0.4 49 3 46 305 6 0 6 0 -1.1 0 -0.6 -1.3 11/13/2004 23:30:00 12.2 1 14.9 9.9 12 1.2 15.3 9.1 0.4 0 0.4 0.4 49 4 51 305 6 0 6 0 -1.1 0 -0.8 -1.1 11/13/2004 23:40:00 14.5 1.4 17.9 10.7 14.1 1.3 17.2 10.7 0.4 0 0.4 0.4 64 10 72 305 6 0 7 0 -1 0.1 -0.6 -1.1 11/13/2004 23:50:00 15.6 1.2 17.9 12.6 15.3 1.3 17.9 11.8 0.4 0 0.4 0.4 67 5 72 305 7 0 7 0 -1.1 0 -1.1 -1.3 11/14/2004 00:00:00 13.6 1.5 17.6 9.9 13.4 1.5 17.6 10.3 0.4 0 0.4 0.4 62 4 65 305 7 0 7 0 -1.1 0 -0.6 -1.1 11/14/2004 00:10:00 13.3 1.1 15.6 10.7 13.1 1.2 15.6 10.3 0.4 0 0.4 0.4 57 4 52 305 7 0 7 0 -1 0 -0.8 -1.1 11/14/2004 00:20:00 13 1.2 16.1 9.5 12.7 1.2 16.1 9.9 0.4 0 0.4 0.4 55 5 48 305 7 0 7 0 -0.9 0 -0.4 -1.1 11/14/2004 00:30:00 13.3 1.1 16.1 10.7 13 1.3 16.4 9.9 0.4 0 0.4 0.4 52 4 47 305 7 0 7 0 -0.9 0 -0.4 -1.1 11/14/2004 00:40:00 12.8 1 15.3 10.3 12.4 1.1 15.3 9.5 0.4 0 0.4 0.4 50 4 57 305 7 0 7 0 -0.8 0 -0.4 -1.1 11/14/2004 00:50:00 13.3 1.1 15.6 10.7 13 1.1 16.1 10.3 0.4 0 0.4 0.4 52 4 55 305 7 0 7 0 -0.7 0 -0.1 -0.8 11/14/2004 01:00:00 12.7 1.2 16.1 9.9 12.5 1.3 15.6 9.5 0.4 0 0.4 0.4 55 4 56 305 8 0 7 0 -0.7 0 -0.1 -0.8 11/14/2004 01:10:00 12.3 1 14.9 9.9 12.1 1.1 14.9 9.1 0.4 0 0.4 0.4 53 4 57 305 8 0 8 0 -0.6 0 -0.1 -0.6 11/14/2004 01:20:00 12.7 1 15.3 10.3 12.6 1.1 14.9 9.9 0.4 0 0.4 0.4 51 4 56 305 8 0 8 0 -0.5 0 0.1 -0.6 11/14/2004 01:30:00 12.6 1 15.3 10.3 12.3 1 15.3 9.9 0.4 0 0.4 0.4 55 3 49 305 8 0 7 0 -0.4 0.1 0.1 -0.6 11/14/2004 01:40:00 11.8 0.9 14.1 9.5 11.6 0.9 14.1 9.1 0.4 0 0.4 0.4 58 3 59 305 8 0 8 0 -0.3 0 0.1 -0.4 11/14/2004 01:50:00 11.8 0.9 13.7 9.5 11.6 1 13.7 8.8 0.4 0 0.4 0.4 62 4 67 305 8 0 8 0 -0.1 0 0.3 -0.4 11/14/2004 02:00:00 12 1 14.1 9.1 11.7 1 14.1 8.4 0.4 0 0.7 0.4 67 4 67 305 8 0 8 0 0 0 0.3 -0.1 11/14/2004 02:10:00 11.8 0.8 13.7 9.1 11.7 0.9 14.1 8.8 0.4 0 0.4 0.4 68 5 62 305 8 0 8 0 0.1 0.1 0.6 0.1 11/14/2004 02:20:00 11.5 0.8 13.3 9.1 11.3 0.8 13.3 8.8 0.4 0 0.4 0.4 67 5 62 305 8 0 8 0 0.1 0.1 0.6 0.1 11/14/2004 02:30:00 10.6 1 13.3 8.4 10.5 1 13 8 0.4 0 0.4 0.4 70 6 78 305 8 0 8 0 0.2 0 0.6 0.1 11/14/2004 02:40:00 10.6 1 14.1 8 10.3 1 13.7 7.2 0.4 0 0.4 0.4 70 6 76 305 8 0 8 0 0.2 0 0.6 0.1 11/14/2004 02:50:00 10.3 0.9 12.6 7.6 10.1 1 12.2 7.2 0.4 0 0.4 0.4 73 6 73 305 8 0 8 0 0.2 0 0.8 0.1 11/14/2004 03:00:00 10.4 0.9 13 7.2 10.1 1 14.5 7.2 0.4 0 0.4 0.4 73 6 72 305 8 0 8 0 0.2 0 0.6 0.1 11/14/2004 03:10:00 10.1 0.7 11.8 8 9.9 0.8 12.2 7.6 0.4 0 0.4 0.4 72 6 78 305 8 0 8 0 0.3 0 0.8 0.1 11/14/2004 03:20:00 9.7 0.8 11.8 7.6 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 72 5 79 305 8 0 8 0 0.2 0 0.8 0.1 11/14/2004 03:30:00 10.1 0.8 12.2 7.6 9.8 0.8 11.8 6.5 0.4 0 0.4 0.4 72 6 67 305 8 0 8 0 0.3 0 0.8 0.1 11/14/2004 03:40:00 9.8 0.9 12.6 7.2 9.5 0.9 11.8 7.2 0.4 0 0.4 0.4 72 5 70 305 8 0 8 0 0.2 0 0.6 0.1 11/14/2004 03:50:00 9.6 0.8 12.6 7.6 9.3 0.8 11.5 7.2 0.4 0 0.4 0.4 72 5 73 305 8 0 8 0 0.2 0 0.6 0.1 11/14/2004 04:00:00 10.1 1 12.2 7.2 9.7 1 12.2 7.2 0.4 0 0.7 0.4 74 5 78 305 8 0 8 0 0.2 0 0.8 0.1 11/14/2004 04:10:00 11.1 0.9 13.3 8.8 10.6 1 13.3 8 0.4 0 0.4 0.4 76 5 65 305 8 0 8 0 0.2 0 0.8 0.1 11/14/2004 04:20:00 10.8 0.9 13.7 8.8 10.4 0.9 13 8 0.4 0 0.4 0.4 72 6 78 305 8 0 8 0 0.2 0 0.6 0.1 11/14/2004 04:30:00 11.2 1 13.3 8.8 10.9 1 13.7 7.6 0.4 0 0.4 0.4 75 6 70 305 8 0 8 0 0.2 0 0.6 0.1 11/14/2004 04:40:00 11.4 1.1 14.5 8 11.1 1.1 14.1 8 0.4 0 0.4 0.4 76 6 79 305 8 0 8 0 0.2 0 0.6 0.1 11/14/2004 04:50:00 11.7 1.2 16.8 8 11.2 1.3 15.6 8 0.4 0 0.4 0.4 76 8 84 305 8 0 8 0 0.2 0 0.6 0.1 11/14/2004 05:00:00 11.9 1.1 14.9 8.8 11.4 1.1 14.1 8.8 0.4 0 0.4 0.4 78 6 73 305 8 0 8 0 0.1 0 0.6 0.1 11/14/2004 05:10:00 12.1 1 15.3 9.1 11.6 1.1 14.1 8.4 0.4 0 0.4 0.4 77 6 76 305 8 0 8 0 0.1 0.1 0.6 0.1 11/14/2004 05:20:00 11.7 1.1 15.3 8.8 11.3 1.1 14.1 7.6 0.4 0 0.4 0.4 76 6 80 305 8 0 8 0 0 0 0.6 0.1 11/14/2004 05:30:00 11.6 1 14.1 8.4 11.2 1 14.1 8 0.4 0 0.4 0.4 77 6 74 305 9 0 9 0 0 0 0.6 0.1 11/14/2004 05:40:00 11.5 1.2 14.5 8.4 11.2 1.2 14.1 8 0.4 0 0.4 0.4 76 7 64 305 9 0 8 0 0 0 0.6 0.1 11/14/2004 05:50:00 11.3 1.2 15.3 8.4 11 1.1 14.1 7.2 0.4 0 0.4 0.4 75 7 66 305 9 0 9 0 0 0 0.6 -0.1 11/14/2004 06:00:00 11.8 1 14.5 9.1 11.4 1 14.1 8.4 0.4 0 0.4 0.4 77 5 82 305 9 0 9 0 0 0 0.6 -0.1 11/14/2004 06:10:00 11.3 0.9 14.1 8.8 10.9 1 13.3 8 0.4 0 0.4 0.4 77 7 82 305 9 0 8 0 0 0 0.6 -0.1 11/14/2004 06:20:00 10.6 1 13.3 8 10.2 1 13.3 7.2 0.4 0 0.4 0.4 76 6 75 305 9 0 8 0 0 0 0.6 0.1 11/14/2004 06:30:00 10.7 1 13 8.4 10.3 1 13 8 0.4 0 0.4 0.4 76 6 78 305 9 0 8 0 0 0 0.6 0.1 11/14/2004 06:40:00 10.4 1 13.3 8.4 10.1 0.9 12.6 8 0.4 0 0.4 0.4 75 6 79 305 8 0 8 0 0.1 0.1 0.6 0.1 11/14/2004 06:50:00 10.6 0.9 13.3 8.4 10.3 1 13 8 0.4 0 0.4 0.4 74 6 75 305 8 0 8 0 0.2 0 0.6 0.1 11/14/2004 07:00:00 10.4 0.8 12.6 8.4 10.1 0.8 11.8 7.6 0.4 0 0.4 0.4 74 5 82 305 8 0 8 0 0.2 0 0.6 0.1 11/14/2004 07:10:00 10.4 0.9 12.6 7.6 10.1 1 12.2 7.6 0.4 0 0.4 0.4 74 5 80 305 8 0 8 0 0.3 0 0.8 0.1 11/14/2004 07:20:00 9.7 0.8 11.5 7.2 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 73 5 81 305 8 0 8 0 0.4 0 0.8 0.3 11/14/2004 07:30:00 9.5 0.7 11.8 7.6 9.2 0.7 11.5 6.8 0.4 0 0.4 0.4 73 5 73 305 8 0 8 0 0.4 0 0.8 0.3 11/14/2004 07:40:00 9.2 0.7 11.1 7.6 8.9 0.8 11.1 7.2 0.4 0 0.4 0.4 74 2 69 305 8 0 8 0 0.5 0 1 0.3 11/14/2004 07:50:00 9.4 0.8 11.8 6.8 9.1 0.9 12.6 6.8 0.4 0 0.4 0.4 75 2 75 305 8 0 8 0 0.5 0 1 0.3 11/14/2004 08:00:00 8.6 1.2 11.8 4.9 8.6 1.2 11.8 5.3 0.4 0 0.4 0.4 78 10 106 305 8 0 8 0 0.6 0.1 1.3 0.6 11/14/2004 08:10:00 6.7 1.7 11.5 2.6 6.4 1.7 11.1 3 0.4 0 0.4 0.4 92 17 105 305 8 0 8 0 1 0 1.5 0.8 11/14/2004 08:20:00 6.1 1.7 10.7 2.3 5.9 1.5 9.5 3 0.4 0 0.4 0.4 103 17 114 305 9 0 8 0 1.3 0 1.7 1 11/14/2004 08:30:00 6.4 1.7 10.7 2.6 6.4 1.5 9.9 3 0.4 0 0.4 0.4 112 16 118 305 9 0 8 0 1.4 0 1.7 1.3 11/14/2004 08:40:00 7.2 1.8 12.6 1.9 7.1 1.7 11.5 3 0.4 0 0.4 0.4 127 15 136 305 8 0 8 0 1.5 0 2 1.3 11/14/2004 08:50:00 8.5 1.1 11.1 5.3 8.3 1.1 11.1 4.9 0.4 0 0.4 0.4 139 9 130 305 8 0 9 0 1.6 0 2 1.5 11/14/2004 09:00:00 8.6 1.6 13 5.3 8.6 1.2 12.2 4.9 0.4 0 0.4 0.4 147 12 144 305 8 0 8 0 1.6 0 2.2 1.5 11/14/2004 09:10:00 10.2 1.5 13.3 5.7 10.1 1.3 13.3 6.5 0.4 0 0.4 0.4 150 9 151 305 8 0 8 0 1.6 0 2.2 1.5 11/14/2004 09:20:00 9.8 1.7 13.7 5.7 9.8 1.5 13.7 6.1 0.4 0 0.4 0.4 154 11 143 305 8 0 8 0 1.7 0.1 2.2 1.5 11/14/2004 09:30:00 10 1.7 14.1 5.7 10.3 1.4 14.5 6.8 0.4 0 0.4 0.4 155 10 160 305 8 0 8 0 1.8 0.1 2.5 1.5 11/14/2004 09:40:00 10 1.7 14.5 5.3 10.4 1.3 13.7 7.2 0.4 0 0.4 0.4 156 9 144 305 8 0 8 0 1.9 0 2.5 1.5 11/14/2004 09:50:00 9.7 1.6 14.5 5.7 9.8 1.5 14.5 6.1 0.4 0 0.4 0.4 152 11 154 305 8 0 8 0 1.8 0.1 2.5 1.5 11/14/2004 10:00:00 9.8 1.8 14.5 5.3 9.8 1.5 13.3 5.7 0.4 0 0.4 0.4 152 11 155 305 8 0 8 0 1.9 0 2.5 1.7 11/14/2004 10:10:00 10.7 1.9 14.5 5.7 10.7 1.5 13.7 6.8 0.4 0 0.4 0.4 152 10 157 305 8 0 8 0 1.9 0 2.2 1.7 11/14/2004 10:20:00 10.4 1.8 15.3 6.1 10.2 1.7 15.6 6.1 0.4 0 0.4 0.4 149 9 152 305 8 0 8 0 1.9 0 2.5 1.5 11/14/2004 10:30:00 10.1 1.7 14.1 4.9 10 1.5 15.3 6.5 0.4 0 0.4 0.4 149 11 152 305 8 0 8 0 1.9 0 2.5 1.7 11/14/2004 10:40:00 9.9 1.8 15.6 4.6 9.9 1.5 14.9 5.3 0.4 0 0.4 0.4 150 10 146 305 8 0 8 0 2 0 2.5 2 11/14/2004 10:50:00 9.7 1.8 14.9 6.1 9.7 1.6 14.5 6.5 0.4 0 0.4 0.4 154 11 154 305 8 0 8 0 2 0 2.5 2 11/14/2004 11:00:00 10.1 2 14.5 5.7 9.9 1.6 14.1 6.5 0.4 0 0.4 0.4 152 10 147 305 8 0 8 0 2.2 0 2.7 2 11/14/2004 11:10:00 9.7 1.6 13.7 5.7 9.6 1.5 14.1 6.5 0.4 0 0.4 0.4 151 10 161 305 8 0 8 0 2 0 2.5 2 11/14/2004 11:20:00 10.2 1.4 13.3 6.5 9.7 1.3 12.6 5.7 0.4 0 0.4 0.4 148 8 158 305 8 0 8 0 1.9 0 2.5 1.7 11/14/2004 11:30:00 9.8 1.5 13.3 5.7 9.4 1.3 13.3 6.5 0.4 0 0.4 0.4 148 10 154 305 8 0 8 0 1.9 0 2.5 1.7 11/14/2004 11:40:00 9.5 1.5 13 5.3 9.4 1.3 13 5.7 0.4 0 0.4 0.4 151 9 158 305 8 0 8 0 1.8 0.1 2.5 1.5 11/14/2004 11:50:00 9.9 1.4 13 4.9 9.5 1.1 12.6 6.8 0.4 0 0.4 0.4 149 9 153 305 8 0 8 0 1.7 0.1 2.2 1.5 11/14/2004 12:00:00 9.1 1.5 13 4.6 9.1 1.1 11.8 6.5 0.4 0 0.4 0.4 152 9 156 305 8 0 8 0 1.7 0.1 2.2 1.5 11/14/2004 12:10:00 8.9 1.5 12.6 4.6 8.8 1.1 11.5 6.1 0.4 0 0.4 0.4 151 9 150 305 8 0 8 0 1.7 0.1 2.2 1.5 11/14/2004 12:20:00 9.5 1.2 12.6 6.5 9.1 1 12.2 6.5 0.4 0 0.4 0.4 148 7 152 305 8 0 8 0 1.6 0 2.2 1.5 11/14/2004 12:30:00 8.9 1.5 12.2 3.8 8.7 1.3 11.8 4.9 0.4 0 0.4 0.4 150 9 152 305 8 0 8 0 1.6 0 2.2 1.5 11/14/2004 12:40:00 8.7 1.2 11.5 5.7 8.4 1.1 11.8 5.7 0.4 0 0.4 0.4 150 8 150 305 8 0 8 0 1.6 0.1 2.2 1.5 11/14/2004 12:50:00 8.6 1.1 11.1 5.3 8.1 0.9 10.3 6.1 0.4 0 0.4 0.4 148 7 156 305 8 0 8 0 1.6 0 2.2 1.5 11/14/2004 13:00:00 8.2 1.2 11.8 5.3 7.9 1 10.3 5.3 0.4 0 0.4 0.4 149 8 147 305 8 0 8 0 1.6 0 2.2 1.5 11/14/2004 13:10:00 8 1 10.7 4.9 7.6 1 10.7 4.9 0.4 0 0.4 0.4 146 8 150 305 8 0 8 0 1.6 0 2 1.5 11/14/2004 13:20:00 7.1 1 10.3 4.9 6.9 0.9 9.5 5.3 0.4 0 0.4 0.4 145 9 151 305 8 0 8 0 1.5 0 2 1.3 11/14/2004 13:30:00 7.6 0.9 9.9 4.9 7.3 0.8 9.5 4.9 0.4 0 0.4 0.4 149 9 151 305 8 0 8 0 1.4 0 2 1.3 11/14/2004 13:40:00 7.2 1.2 10.3 4.6 7 1 9.5 4.2 0.4 0 0.4 0.4 151 8 156 305 8 0 8 0 1.4 0 2 1.3 11/14/2004 13:50:00 8 1 10.3 4.2 7.8 0.9 10.3 5.3 0.4 0 0.4 0.4 154 6 151 305 8 0 8 0 1.4 0 2 1.3 11/14/2004 14:00:00 6.6 1.2 9.5 3.4 8.2 1.1 11.1 6.1 0.4 0 0.4 0.4 165 8 147 305 8 0 8 0 1.6 0.1 2.2 1.3 11/14/2004 14:10:00 6.5 1 9.1 4.2 7.3 1.5 11.1 4.2 0.4 0 0.4 0.4 198 22 190 305 8 0 8 0 1.5 0.4 2.5 0.8 11/14/2004 14:20:00 4.8 0.5 5.7 3 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 220 5 227 305 7 0 7 0 0.6 0.1 1.3 0.6 11/14/2004 14:30:00 4.3 0.4 4.9 2.6 4.3 0.5 5.3 2.3 0.4 0 0.4 0.4 215 6 213 305 7 0 7 0 0.4 0 1 0.3 11/14/2004 14:40:00 5.1 1.2 7.6 3 3.9 0.7 5.7 2.6 0.4 0 0.4 0.4 251 15 265 305 7 0 7 0 0.3 0.1 0.8 0.1 11/14/2004 14:50:00 6.4 0.8 8.4 3.4 4.5 0.7 6.1 2.3 0.4 0 0.4 0.4 268 6 268 305 6 0 6 0 0 0.1 0.6 0.1 11/14/2004 15:00:00 6.4 0.8 8 3.8 4.6 0.7 6.5 2.6 0.4 0 0.4 0.4 264 5 272 305 6 0 6 0 0 0 0.6 -0.1 11/14/2004 15:10:00 6.5 0.7 8 4.2 5.1 0.8 7.6 3 0.4 0 0.4 0.4 258 5 259 305 6 0 6 0 0 0 0.6 -0.1 11/14/2004 15:20:00 7.2 0.8 9.5 4.6 6.1 0.9 8.4 3.4 0.4 0 0.4 0.4 253 3 252 305 6 0 6 0 0.1 0.1 0.6 0.1 11/14/2004 15:30:00 8.4 0.8 10.3 5.7 7.1 1 9.5 4.6 0.4 0 0.4 0.4 252 0 252 305 6 0 6 0 0 0 0.6 -0.1 11/14/2004 15:40:00 9.1 1.1 11.8 6.1 7.3 1.3 10.3 3.8 0.4 0 0.4 0.4 252 0 252 305 6 0 6 0 -0.1 0 0.6 -0.4 11/14/2004 15:50:00 9.8 1.5 13 6.5 7.4 1.3 11.1 4.2 0.4 0 0.4 0.4 253 0 253 305 6 0 6 0 -0.2 0.1 0.3 -0.4 11/14/2004 16:00:00 10.8 1.7 13.3 6.1 7.9 1.3 10.7 4.6 0.4 0 0.4 0.4 253 0 253 305 6 0 6 0 -0.4 0.1 0.1 -0.6 11/14/2004 16:10:00 11.2 1.5 14.1 6.8 8.3 1.2 11.1 4.9 0.4 0 0.4 0.4 253 0 253 305 6 0 6 0 -0.5 0.1 0.1 -0.6 11/14/2004 16:20:00 11.6 1.7 14.9 7.2 8.6 1.2 11.5 5.7 0.4 0 0.7 0.4 253 0 253 305 6 0 6 0 -0.6 0 -0.1 -0.6 11/14/2004 16:30:00 12 1.4 14.9 7.6 8.9 1.1 11.5 6.1 0.4 0 0.4 0.4 253 0 254 305 6 0 6 0 -0.8 0 -0.1 -1.1 11/14/2004 16:40:00 11 1.5 14.5 7.6 8.6 1.3 12.6 5.3 0.4 0 0.4 0.4 265 12 254 305 6 0 6 0 -0.8 0 -0.4 -1.1 11/14/2004 16:50:00 12 1.6 15.3 8 9.1 1.2 11.8 6.1 0.4 0 0.4 0.4 271 5 267 305 6 0 6 0 -1 0.1 -0.4 -1.1 11/14/2004 17:00:00 12.2 1.7 15.3 6.8 9.4 1.5 13.3 5.3 0.4 0 0.4 0.4 272 3 269 305 6 0 6 0 -1.1 0 -0.6 -1.1 11/14/2004 17:10:00 12.3 1.4 15.3 7.6 9.1 1.2 12.6 5.3 0.4 0 0.4 0.4 270 0 271 305 6 0 6 0 -1.1 0 -0.6 -1.1 11/14/2004 17:20:00 13.7 1.6 16.4 9.9 10.3 1.3 13.3 6.1 0.4 0 0.4 0.4 271 0 271 305 5 0 5 0 -1.2 0 -0.6 -1.3 11/14/2004 17:30:00 13.3 1.5 16.1 8.4 10.3 1.3 13.3 6.8 0.4 0 0.4 0.4 273 4 270 305 5 0 6 0 -1.2 0 -0.8 -1.3 11/14/2004 17:40:00 14 1.7 17.6 9.1 11.2 1.7 14.9 5.3 0.4 0 0.4 0.4 276 3 279 305 5 0 5 0 -1.4 0.1 -0.8 -1.5 11/14/2004 17:50:00 13.7 1.7 17.2 9.5 10.6 1.4 14.9 7.2 0.4 0 0.4 0.4 273 6 274 305 5 0 5 0 -1.6 0 -1.1 -1.8 11/14/2004 18:00:00 13.8 1.6 17.2 7.2 10.8 1.4 14.1 6.1 0.4 0 0.4 0.4 273 2 273 305 5 0 5 0 -1.6 0 -1.1 -1.8 11/14/2004 18:10:00 14.2 2.2 18.3 8 11 1.7 15.3 5.7 0.4 0 0.4 0.4 272 0 272 305 5 0 5 0 -1.8 0 -1.1 -2 11/14/2004 18:20:00 14 1.9 17.9 8.8 10.9 1.6 14.5 5.7 0.4 0 0.4 0.4 271 0 271 305 5 0 5 0 -1.9 0 -1.3 -2 11/14/2004 18:30:00 14.7 2.1 19.1 9.9 11.7 1.8 17.2 6.8 0.4 0 0.4 0.4 271 0 271 305 5 0 5 0 -2 0.1 -1.5 -2.2 11/14/2004 18:40:00 15.6 1.9 19.9 9.9 12.3 1.7 16.8 7.2 0.4 0 0.4 0.4 270 5 261 305 5 0 5 0 -2.1 0 -1.8 -2.2 11/14/2004 18:50:00 15.4 2 19.5 9.9 12.3 1.7 17.6 7.2 0.4 0 0.4 0.4 275 2 275 305 5 0 5 0 -2.2 0 -1.8 -2.2 11/14/2004 19:00:00 14.7 2.5 19.5 8 11.7 2.1 16.8 6.5 0.4 0 0.4 0.4 271 5 259 305 5 0 6 0 -2.2 0 -2 -2.4 11/14/2004 19:10:00 15.7 2.3 19.9 9.1 12.4 2.1 17.2 5.7 0.4 0 0.4 0.4 266 1 265 305 5 0 5 0 -2.3 0 -1.8 -2.4 11/14/2004 19:20:00 16.5 2.1 21 11.1 13.1 1.9 17.6 7.6 0.4 0 0.4 0.4 268 3 267 305 5 0 5 0 -2.5 0 -2 -2.7 11/14/2004 19:30:00 15.7 2.4 21.4 9.5 12.4 2 18.3 7.6 0.4 0 0.4 0.4 271 0 271 305 5 0 5 0 -2.7 0 -2 -2.7 11/14/2004 19:40:00 15.3 2.8 20.2 7.2 12.4 2.5 18.3 5.3 0.4 0 0.4 0.4 272 0 271 305 5 0 5 0 -2.7 0 -2.4 -2.9 11/14/2004 19:50:00 17 2.1 21.4 10.7 13.6 2.1 20.2 8.4 0.4 0 0.4 0.4 267 3 265 305 5 0 5 0 -2.8 0 -2.7 -3.1 11/14/2004 20:00:00 16.7 2.7 21.8 10.7 13.6 2.6 19.5 6.8 0.4 0 0.4 0.4 266 1 266 305 5 0 5 0 -2.9 0 -2.4 -3.1 11/14/2004 20:10:00 16.8 2.6 21.4 8 13.4 2.1 18.7 8 0.4 0 0.4 0.4 266 4 264 305 5 0 5 0 -3 0 -2.4 -3.1 11/14/2004 20:20:00 15.6 2.2 20.6 9.9 12.6 2.2 17.9 6.5 0.4 0 0.4 0.4 276 4 273 305 5 0 5 0 -2.9 0 -2.4 -3.1 11/14/2004 20:30:00 17.8 2.7 22.9 11.5 14.6 2.5 21 8.8 0.4 0 0.4 0.4 265 6 268 305 4 0 5 0 -3 0.1 -2.4 -3.3 11/14/2004 20:40:00 16.6 2.5 21.8 9.1 13.5 2.4 19.5 7.2 0.4 0 0.4 0.4 276 5 276 305 4 0 4 0 -3.1 0.1 -2.7 -3.3 11/14/2004 20:50:00 15.9 2.1 19.9 8 12.7 2 17.9 6.5 0.4 0 0.4 0.4 270 5 264 305 4 0 4 0 -3.2 0.1 -2.7 -3.3 11/14/2004 21:00:00 16 2.4 21.4 9.1 13.2 2.2 19.1 8 0.4 0 0.4 0.4 274 7 281 305 4 0 4 0 -3.3 0 -2.7 -3.6 11/14/2004 21:10:00 16.8 2.1 21.4 11.5 13.6 1.8 18.3 8.8 0.4 0 0.4 0.4 274 4 277 305 3 0 3 0 -3.4 0 -2.9 -3.6 11/14/2004 21:20:00 15.5 2.8 22.1 9.5 12.4 2.4 18.7 6.8 0.4 0 0.4 0.4 270 7 268 305 3 0 3 0 -3.4 0 -2.7 -3.6 11/14/2004 21:30:00 17.3 2.2 22.1 11.5 14.1 2.1 19.9 9.5 0.4 0 0.4 0.4 275 4 274 305 3 0 3 0 -3.5 0 -2.9 -3.8 11/14/2004 21:40:00 16.6 2.4 21.8 9.5 12.9 2.1 19.9 8 0.4 0 0.4 0.4 268 5 259 305 2 0 2 0 -3.6 0 -3.1 -3.8 11/14/2004 21:50:00 17.4 2.5 21.8 10.3 13.7 2.1 17.6 6.5 0.4 0 0.4 0.4 272 6 269 305 2 0 2 0 -3.6 0.1 -3.1 -3.8 11/14/2004 22:00:00 18.3 1.8 22.6 13.3 14.5 1.7 19.1 9.5 0.4 0 0.4 0.4 266 5 265 305 2 0 2 0 -3.7 0.1 -3.3 -3.8 11/14/2004 22:10:00 16.7 2.6 22.1 10.7 13.3 2.3 21 8 0.4 0 0.4 0.4 270 6 268 305 2 0 2 0 -3.7 0.1 -3.1 -4 11/14/2004 22:20:00 17.3 2.4 22.1 9.5 13.9 2.3 19.1 7.6 0.4 0 0.4 0.4 267 6 268 305 2 0 2 0 -3.9 0 -3.3 -4 11/14/2004 22:30:00 17.7 2.1 22.9 10.7 14.3 2 19.5 8.8 0.4 0 0.4 0.4 269 7 262 305 2 0 2 0 -4 0 -3.3 -4 11/14/2004 22:40:00 15.7 2.8 21.4 9.1 12.7 2.7 19.1 7.2 0.4 0 0.4 0.4 268 6 262 305 1 0 1 0 -4 0.1 -3.6 -4.2 11/14/2004 22:50:00 17.6 2.2 22.9 11.8 14.5 2.2 20.2 9.1 0.4 0 0.4 0.4 264 6 268 305 1 0 1 0 -4.3 0.1 -3.8 -4.5 11/14/2004 23:00:00 16.6 2.1 21.4 10.3 13.6 1.8 18.3 8.4 0.4 0 0.4 0.4 268 6 259 305 1 0 1 0 -4.4 0 -4 -4.7 11/14/2004 23:10:00 15.5 1.6 19.5 11.8 12.5 1.7 16.4 8.4 0.4 0 0.4 0.4 267 7 252 305 1 0 1 0 -4.5 0 -4 -4.7 11/14/2004 23:20:00 16 2.3 21 9.9 12.7 2 18.7 8.4 0.4 0 0.4 0.4 268 6 261 305 1 0 1 0 -4.6 0.1 -4 -4.7 11/14/2004 23:30:00 15.5 1.8 20.2 8.8 12.7 1.9 17.9 7.2 0.4 0 0.4 0.4 270 8 275 305 1 0 1 0 -4.7 0.1 -4.2 -4.9 11/14/2004 23:40:00 14.8 1.9 19.1 8.8 11.9 1.7 17.6 8 0.4 0 0.4 0.4 267 7 268 305 1 0 0 0 -4.6 0 -4 -4.7 11/14/2004 23:50:00 15.6 1.8 20.2 9.5 12.8 1.9 17.9 7.6 0.4 0 0.4 0.4 264 7 260 305 0 0 0 0 -4.7 0.1 -4 -4.9 11/15/2004 00:00:00 15.4 1.9 19.9 9.5 12.3 1.7 18.3 8.4 0.4 0 0.4 0.4 272 6 279 305 0 0 0 0 -4.7 0 -4.5 -4.9 11/15/2004 00:10:00 15.8 2.1 20.2 9.9 12.8 1.9 17.9 8 0.4 0 0.4 0.4 266 7 262 305 0 0 0 0 -4.9 0 -4.7 -4.9 11/15/2004 00:20:00 16.2 2.4 20.6 10.3 14 2.3 18.7 8.8 0.4 0 0.4 0.4 260 7 259 305 0 0 0 0 -4.9 0 -4.7 -5.1 11/15/2004 00:30:00 15.8 2.2 20.6 9.9 12.6 2.1 17.6 7.2 0.4 0 0.4 0.4 269 7 268 305 0 0 0 0 -5 0 -4.5 -5.1 11/15/2004 00:40:00 15.7 2.3 21.4 8 13.6 2.5 20.6 7.2 0.4 0 0.4 0.4 259 8 254 305 0 0 0 0 -5.1 0 -4.9 -5.1 11/15/2004 00:50:00 16.5 1.8 20.2 9.9 13.7 2.2 19.1 8.4 0.4 0 0.4 0.4 263 7 262 305 0 0 0 0 -5.2 0 -4.7 -5.6 11/15/2004 01:00:00 15.8 1.9 19.5 10.7 12.7 1.8 17.2 7.2 0.4 0 0.4 0.4 266 7 267 305 0 0 0 0 -5.5 0 -5.1 -5.6 11/15/2004 01:10:00 16.5 2.4 21.4 9.1 13.7 2.5 19.5 6.5 0.4 0 0.4 0.4 263 8 261 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/15/2004 01:20:00 16.2 1.8 20.2 10.7 13.7 2.2 19.9 7.2 0.4 0 0.4 0.4 260 8 258 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/15/2004 01:30:00 16.1 2.6 21.4 9.5 14.3 2.7 19.5 7.6 0.4 0 0.4 0.4 254 8 259 305 0 0 0 0 -5.8 0.1 -5.3 -6 11/15/2004 01:40:00 16.4 2.3 20.6 9.9 14.3 2.4 19.1 8.8 0.4 0 0.4 0.4 258 7 261 305 0 0 0 0 -5.8 0.1 -5.6 -6 11/15/2004 01:50:00 14.8 2.2 19.1 7.6 12.2 2.2 17.9 6.8 0.4 0 0.4 0.4 268 8 256 305 0 0 0 0 -6 0 -5.6 -6.2 11/15/2004 02:00:00 14.6 2.6 19.5 6.8 11.7 2.2 17.2 6.1 0.4 0 0.4 0.4 268 9 273 305 0 0 0 0 -5.9 0 -5.8 -6 11/15/2004 02:10:00 15.4 2 19.9 9.9 12.7 2.3 18.7 7.6 0.4 0 0.4 0.4 262 8 256 305 0 0 0 0 -6 0 -5.8 -6 11/15/2004 02:20:00 15.8 2 19.5 8.8 14.3 2.2 18.7 7.6 0.4 0 0.4 0.4 252 8 242 305 0 0 0 0 -6 0 -5.8 -6 11/15/2004 02:30:00 15.7 1.8 20.2 9.5 13.3 2 18.3 8 0.4 0 0.4 0.4 263 7 261 305 0 0 0 0 -6 0 -5.8 -6 11/15/2004 02:40:00 15.1 1.7 18.3 10.3 13.3 2.2 17.9 8.4 0.4 0 0.4 0.4 258 9 264 305 0 0 0 0 -6 0 -5.8 -6.2 11/15/2004 02:50:00 14.7 2.3 20.2 9.1 13.1 2.4 19.1 6.1 0.4 0 0.4 0.4 255 9 254 305 0 0 0 0 -6.2 0 -5.8 -6.4 11/15/2004 03:00:00 14.8 2.2 21 8.8 13 2.5 19.5 7.2 0.4 0 0.4 0.4 257 8 251 305 0 0 0 0 -6.2 0 -5.8 -6.4 11/15/2004 03:10:00 17.2 1.7 21 11.1 15.6 2.1 19.5 10.3 0.4 0 0.4 0.4 253 6 249 305 0 0 0 0 -6.3 0 -6 -6.7 11/15/2004 03:20:00 16.3 1.7 19.9 11.1 14.7 2 18.7 8.4 0.4 0 0.4 0.4 251 7 250 305 0 0 0 0 -6.5 0 -6 -6.7 11/15/2004 03:30:00 15.8 1.6 19.9 9.5 14.3 1.9 19.5 8.4 0.4 0 0.4 0.4 253 9 256 305 0 0 0 0 -6.3 0 -6 -6.4 11/15/2004 03:40:00 15 1.7 20.2 9.5 12.8 2 17.6 6.8 0.4 0 0.4 0.4 260 7 261 305 0 0 0 0 -6.4 0 -6 -6.7 11/15/2004 03:50:00 15.8 1.7 19.5 11.1 13.7 1.8 17.9 8 0.4 0 0.4 0.4 259 6 263 305 0 0 0 0 -6.5 0 -6 -6.7 11/15/2004 04:00:00 16.1 1.9 20.6 11.8 14.5 2 19.9 9.5 0.4 0 0.4 0.4 255 6 257 305 0 0 0 0 -6.6 0.1 -6.4 -6.9 11/15/2004 04:10:00 15.8 1.5 19.9 10.3 14 2 18.3 7.6 0.4 0 0.4 0.4 254 9 268 305 0 0 0 0 -6.5 0.1 -6.2 -6.9 11/15/2004 04:20:00 16.2 1.9 20.2 11.1 14.9 2.2 19.5 9.1 0.4 0 0.4 0.4 252 8 249 305 0 0 0 0 -6.7 0 -6.4 -6.9 11/15/2004 04:30:00 16.5 2.2 20.6 10.3 15.3 2.2 20.2 10.3 0.4 0 0.4 0.4 245 7 246 305 0 0 0 0 -6.7 0.1 -6.4 -6.9 11/15/2004 04:40:00 15.9 1.9 19.9 10.3 14.5 2.2 18.7 6.8 0.4 0 0.4 0.4 250 7 254 305 0 0 0 0 -6.9 0.1 -6.7 -7.1 11/15/2004 04:50:00 15.4 1.8 19.1 10.3 14.3 2 18.7 7.6 0.4 0 0.4 0.4 250 7 251 305 0 0 0 0 -6.7 0 -6.4 -6.9 11/15/2004 05:00:00 15.4 2.2 20.2 8.4 13.7 2.3 19.1 8.4 0.4 0 0.4 0.4 255 7 256 305 0 0 0 0 -6.5 0 -6 -6.7 11/15/2004 05:10:00 15.7 2.1 20.2 9.9 14.5 2.2 19.9 8.4 0.4 0 0.7 0.4 249 7 252 305 0 0 0 0 -6.8 0.1 -6.4 -7.1 11/15/2004 05:20:00 15.8 1.6 19.5 9.5 14.7 1.8 18.3 8.8 0.4 0 0.4 0.4 245 6 250 305 0 0 0 0 -6.7 0 -6.2 -6.9 11/15/2004 05:30:00 15.4 2 19.5 8.8 14 2.2 18.7 8.4 0.4 0 0.4 0.4 251 8 250 305 0 0 0 0 -6.5 0 -6 -6.7 11/15/2004 05:40:00 15.5 1.5 20.2 9.5 14.2 1.7 17.9 8.8 0.4 0 0.4 0.4 254 6 266 305 0 0 0 0 -6.5 0 -6 -6.7 11/15/2004 05:50:00 14 2.2 19.9 9.1 12.7 2.3 19.5 7.6 0.4 0 0.4 0.4 253 6 245 305 0 0 0 0 -6.6 0 -6 -6.9 11/15/2004 06:00:00 14.1 2.1 18.3 8.8 13 2.1 18.3 7.6 0.4 0 0.4 0.4 249 8 242 305 0 0 0 0 -6.6 0.1 -6 -6.9 11/15/2004 06:10:00 14.5 1.5 17.9 9.5 13.2 1.7 17.2 8 0.4 0 0.4 0.4 248 8 244 305 0 0 0 0 -6.7 0.1 -6.2 -7.1 11/15/2004 06:20:00 13.3 1.7 17.6 9.1 12.1 1.8 16.4 8 0.4 0 0.4 0.4 250 8 251 305 0 0 0 0 -6.8 0 -6.4 -6.9 11/15/2004 06:30:00 14 1.3 17.2 10.7 13.2 1.5 17.2 9.1 0.4 0 0.4 0.4 241 6 249 305 0 0 0 0 -6.9 0.1 -6.2 -7.1 11/15/2004 06:40:00 13.7 1.5 17.6 9.5 12.6 1.7 17.2 8 0.4 0 0.4 0.4 247 9 238 305 0 0 0 0 -6.8 0 -6.2 -6.9 11/15/2004 06:50:00 13.7 1.8 17.2 9.5 12.6 1.9 16.8 8 0.4 0 0.4 0.4 247 8 258 305 0 0 0 0 -6.6 0 -6 -6.9 11/15/2004 07:00:00 13.4 2 17.6 8.8 12.4 2.2 17.6 7.6 0.4 0 0.4 0.4 248 8 246 305 0 0 0 0 -6.8 0.1 -6.2 -7.1 11/15/2004 07:10:00 14.5 1.7 17.9 8.4 12.8 2.1 17.2 7.2 0.4 0 0.4 0.4 255 9 239 305 0 0 0 0 -6.8 0 -6.2 -6.9 11/15/2004 07:20:00 12.8 1.7 16.8 7.6 11.8 1.9 16.1 6.8 0.4 0 0.4 0.4 246 9 246 305 0 0 0 0 -6.9 0.1 -6.2 -7.1 11/15/2004 07:30:00 13.5 1.7 17.6 9.9 12.2 1.8 17.6 8 0.4 0 0.4 0.4 253 8 255 305 0 0 0 0 -6.7 0.2 -6.2 -7.1 11/15/2004 07:40:00 14.5 2.1 18.7 8.8 13 2.3 19.1 7.2 0.4 0 0.4 0.4 253 6 251 305 0 0 0 0 -6.6 0 -6.2 -6.9 11/15/2004 07:50:00 14 1.5 17.6 9.9 12.6 1.7 17.2 7.6 0.4 0 0.4 0.4 248 9 258 305 0 0 0 0 -6.5 0 -6.2 -6.9 11/15/2004 08:00:00 13.9 1.8 19.5 9.5 12.9 2.1 19.5 8 0.4 0 0.4 0.4 242 7 233 305 0 0 0 0 -6.6 0 -6.4 -6.9 11/15/2004 08:10:00 14.6 1.8 19.1 9.1 13.6 2 17.6 8.8 0.4 0 0.4 0.4 247 6 241 305 0 0 0 0 -6.7 0 -6.4 -6.9 11/15/2004 08:20:00 12.5 1.7 16.1 8.4 11.6 1.7 15.6 7.6 0.4 0 0.4 0.4 246 8 243 305 0 0 0 0 -6.6 0 -6.7 -6.9 11/15/2004 08:30:00 11.5 1.3 14.9 6.8 10.6 1.5 14.1 6.1 0.4 0 0.4 0.4 247 9 253 305 0 0 0 0 -6.6 0 -6.7 -6.9 11/15/2004 08:40:00 13 1.3 15.6 8.8 11.8 1.8 15.3 6.5 0.4 0 0.7 0.4 249 9 241 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/15/2004 08:50:00 12.7 1.5 16.1 7.2 11.8 1.7 14.9 6.1 0.4 0 0.4 0.4 246 7 239 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/15/2004 09:00:00 13 1.3 15.6 9.1 11.9 1.5 15.3 7.6 0.4 0 0.4 0.4 250 6 245 305 0 0 0 0 -6.5 0 -6 -6.9 11/15/2004 09:10:00 10.7 1.1 13.3 7.6 9.6 1.2 12.6 6.1 0.4 0 0.4 0.4 249 7 250 305 0 0 0 0 -6.9 0.1 -6.4 -7.1 11/15/2004 09:20:00 11.6 1.6 15.3 7.6 10.9 1.7 14.9 6.8 0.4 0 0.4 0.4 241 7 237 305 0 0 0 0 -7 0.2 -6.4 -7.5 11/15/2004 09:30:00 11.6 1.6 14.5 7.2 10.4 1.6 13.3 6.1 0.4 0 0.4 0.4 251 8 261 305 0 0 0 0 -7.1 0 -6.9 -7.3 11/15/2004 09:40:00 11 1.7 14.5 6.8 10.2 1.9 14.1 5.7 0.4 0 0.4 0.4 246 7 244 305 0 0 0 0 -7 0.1 -6.4 -7.1 11/15/2004 09:50:00 11.7 1.8 15.3 6.5 10.9 1.9 14.9 6.5 0.4 0 0.4 0.4 242 6 251 305 0 0 0 0 -6.8 0.1 -6.4 -7.1 11/15/2004 10:00:00 11.9 1.3 14.9 7.6 11 1.3 14.1 6.5 0.4 0 0.4 0.4 244 7 242 305 0 0 0 0 -6.6 0 -6.7 -6.9 11/15/2004 10:10:00 11.4 1.6 15.6 6.8 10.6 1.7 14.9 6.5 0.4 0 0.4 0.4 240 7 236 305 0 0 0 0 -6.6 0 -6.4 -6.7 11/15/2004 10:20:00 11.9 1.3 14.9 8.4 11.1 1.4 14.1 7.6 0.4 0 0.4 0.4 232 7 236 305 0 0 0 0 -6.6 0 -6.4 -6.7 11/15/2004 10:30:00 11.3 1.1 13.7 7.6 10.5 1.2 13.3 7.2 0.4 0 0.4 0.4 237 8 244 305 0 0 0 0 -6.5 0 -6.4 -6.9 11/15/2004 10:40:00 11 1.1 13.7 7.2 10 1.3 13 6.8 0.4 0 0.7 0.4 243 9 249 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/15/2004 10:50:00 11.2 1 13.3 8 10.4 1.1 13 6.8 0.4 0 0.4 0.4 239 7 220 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/15/2004 11:00:00 11.2 1.5 14.9 7.6 10.4 1.6 14.1 6.5 0.4 0 0.4 0.4 234 6 229 305 0 0 0 0 -6.5 0 -6 -6.9 11/15/2004 11:10:00 12.5 1.4 16.1 8.8 11.5 1.5 15.6 7.6 0.4 0 0.4 0.4 246 9 246 305 0 0 0 0 -6.7 0.1 -6 -6.9 11/15/2004 11:20:00 11.8 1.2 14.9 8.4 11 1.3 13.7 7.2 0.4 0 0.4 0.4 238 6 241 305 0 0 0 0 -6.5 0.1 -6 -6.9 11/15/2004 11:30:00 11.8 1.2 14.5 8.4 11 1.4 14.1 7.2 0.4 0 0.4 0.4 240 6 235 305 0 0 0 0 -6.6 0 -6 -6.9 11/15/2004 11:40:00 12 1.3 14.9 8.4 11.2 1.5 14.1 6.8 0.4 0 0.4 0.4 241 5 238 305 0 0 0 0 -6.4 0.1 -5.8 -6.7 11/15/2004 11:50:00 11.1 1.3 14.5 7.6 10.2 1.3 13.7 6.5 0.4 0 0.4 0.4 241 7 244 305 0 0 0 0 -6.4 0 -6 -6.7 11/15/2004 12:00:00 11.9 1.5 15.3 7.6 11 1.6 14.1 6.5 0.4 0 0.4 0.4 242 9 242 305 0 0 0 0 -6.4 0.1 -5.8 -6.7 11/15/2004 12:10:00 11.1 1.3 14.1 8 10.3 1.5 14.1 6.8 0.4 0 0.4 0.4 248 6 251 305 0 0 0 0 -6.6 0 -6 -6.9 11/15/2004 12:20:00 10.9 1.6 13.7 6.8 10 1.7 13.7 5.7 0.4 0 0.4 0.4 244 8 234 305 0 0 0 0 -6.3 0 -5.8 -6.7 11/15/2004 12:30:00 10 1.1 13 6.5 9.1 1.2 12.6 5.7 0.4 0 0.4 0.4 248 8 242 305 0 0 0 0 -6.3 0 -6 -6.4 11/15/2004 12:40:00 11 1.5 13.7 7.2 10.3 1.6 13.3 6.1 0.4 0 0.4 0.4 239 8 233 305 0 0 0 0 -6.2 0 -5.8 -6.4 11/15/2004 12:50:00 10.1 1.3 13.3 6.1 8.6 1.3 12.2 4.9 0.4 0 0.4 0.4 257 6 258 305 0 0 0 0 -6.6 0 -6 -6.9 11/15/2004 13:00:00 9 1.3 12.6 5.7 8.3 1.4 12.6 4.6 0.4 0 0.4 0.4 241 9 241 305 0 0 0 0 -6.4 0 -5.8 -6.7 11/15/2004 13:10:00 10.3 1.2 13.3 6.5 9.6 1.4 13 6.1 0.4 0 0.4 0.4 249 7 245 305 0 0 0 0 -6.4 0 -6 -6.7 11/15/2004 13:20:00 9.4 1.3 11.8 6.1 8.6 1.5 11.8 5.3 0.4 0 0.4 0.4 252 6 245 305 0 0 0 0 -6.4 0.1 -5.8 -6.7 11/15/2004 13:30:00 8.8 1.1 11.5 5.3 8 1.2 11.5 4.6 0.4 0 0.4 0.4 250 7 257 305 0 0 0 0 -6.2 0 -5.8 -6.4 11/15/2004 13:40:00 8.1 0.8 10.3 6.1 7.7 0.8 9.5 5.3 0.4 0 0.4 0.4 243 5 245 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/15/2004 13:50:00 8.7 1 11.5 6.5 7.9 1 10.3 5.3 0.4 0 0.4 0.4 240 9 231 305 0 0 0 0 -6.2 0 -5.8 -6.4 11/15/2004 14:00:00 11.3 1.2 14.9 8.4 10.5 1.2 13.7 7.6 0.4 0 0.7 0.4 231 7 237 305 0 0 0 0 -6 0 -5.6 -6 11/15/2004 14:10:00 11.1 1.7 16.1 8 10.4 1.7 15.3 6.5 0.4 0 0.4 0.4 240 13 218 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/15/2004 14:20:00 9.6 0.9 12.6 7.2 9 1 11.8 6.1 0.4 0 0.4 0.4 245 6 239 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/15/2004 14:30:00 8.7 1.3 11.5 4.9 8.1 1.3 11.5 4.9 0.4 0 0.4 0.4 240 9 252 305 0 0 0 0 -6 0 -5.8 -6.2 11/15/2004 14:40:00 11.8 1.7 15.6 6.8 10.9 1.7 15.6 6.1 0.4 0 0.4 0.4 236 7 238 305 0 0 0 0 -5.9 0.1 -5.1 -6 11/15/2004 14:50:00 10 1.7 13.7 6.1 9.3 1.8 13.3 5.3 0.4 0 0.4 0.4 242 7 242 305 0 0 0 0 -6 0 -5.6 -6 11/15/2004 15:00:00 9.6 1.6 13 6.1 8.8 1.7 12.6 5.3 0.4 0 0.4 0.4 242 7 255 305 0 0 0 0 -5.8 0.1 -5.3 -6 11/15/2004 15:10:00 10.4 1.3 13.3 6.8 9.6 1.4 13.3 6.1 0.4 0 0.4 0.4 243 8 250 305 0 0 0 0 -5.7 0 -5.1 -6 11/15/2004 15:20:00 10.8 1.6 15.3 7.2 10 1.7 14.1 6.1 0.4 0 0.4 0.4 246 7 248 305 0 0 0 0 -5.8 0 -5.3 -6 11/15/2004 15:30:00 10.6 1.2 13.7 6.8 9.8 1.3 13 5.3 0.4 0 0.4 0.4 248 7 242 305 0 0 0 0 -6 0 -5.6 -6 11/15/2004 15:40:00 10.3 1.6 13.3 5.7 9.6 1.7 13 4.2 0.4 0 0.4 0.4 245 7 258 305 0 0 0 0 -5.9 0 -5.6 -6 11/15/2004 15:50:00 9.1 1.1 11.8 6.5 8.1 1.3 11.5 5.3 0.4 0 0.4 0.4 252 8 246 305 0 0 0 0 -5.9 0 -5.6 -6 11/15/2004 16:00:00 8.9 1.4 13 5.3 8.2 1.4 11.8 4.6 0.4 0 0.4 0.4 239 7 250 305 0 0 0 0 -5.9 0.1 -5.3 -6 11/15/2004 16:10:00 9.8 1 12.6 7.2 9.2 1 11.8 6.5 0.4 0 0.4 0.4 240 7 225 305 0 0 0 0 -5.6 0 -5.1 -5.8 11/15/2004 16:20:00 9 1.1 11.8 6.1 8.4 1.2 11.5 4.9 0.4 0 0.4 0.4 237 9 223 305 0 0 0 0 -5.6 0 -4.9 -5.8 11/15/2004 16:30:00 8.7 0.7 10.3 6.5 8.1 0.8 10.3 5.7 0.4 0 0.4 0.4 238 8 239 305 0 0 0 0 -5.5 0 -4.9 -5.6 11/15/2004 16:40:00 7.6 0.9 10.3 4.9 6.1 0.9 8.4 3.8 0.4 0 0.4 0.4 264 10 243 305 0 0 0 0 -5.6 0.1 -4.9 -5.8 11/15/2004 16:50:00 7.8 1 10.3 4.6 6 0.9 8.8 3.4 0.4 0 0.4 0.4 268 6 269 305 0 0 0 0 -5.9 0 -5.6 -6 11/15/2004 17:00:00 7.6 0.9 9.5 4.9 5.8 0.8 7.6 3.4 0.4 0 0.4 0.4 266 5 258 305 0 0 0 0 -6.1 0 -6 -6.2 11/15/2004 17:10:00 6.7 1 8.8 4.6 5.5 0.7 7.2 3.8 0.4 0 0.4 0.4 272 7 270 305 0 0 0 0 -6.1 0 -6 -6.2 11/15/2004 17:20:00 5.6 0.6 7.2 3.8 4.5 0.6 6.5 3 0.4 0 0.4 0.4 261 8 265 305 0 0 0 0 -6.1 0 -6 -6.2 11/15/2004 17:30:00 6 0.8 7.6 3.8 5.3 0.8 7.2 3.4 0.4 0 0.4 0.4 253 7 258 305 0 0 0 0 -5.9 0.1 -5.6 -6 11/15/2004 17:40:00 5.7 0.9 7.6 3.4 5.1 0.9 6.8 3 0.4 0 0.4 0.4 249 11 254 305 0 0 0 0 -5.7 0 -5.1 -5.8 11/15/2004 17:50:00 5.6 0.8 7.2 3.8 5.2 1 6.8 2.6 0.4 0 0.4 0.4 250 7 259 305 0 0 0 0 -5.5 0 -5.6 -5.8 11/15/2004 18:00:00 6 0.7 7.6 4.2 5.4 0.8 7.2 3.4 0.4 0 0.4 0.4 246 10 238 305 0 0 0 0 -5.5 0 -5.1 -5.6 11/15/2004 18:10:00 6.5 0.8 8 3.4 6 1 8 2.6 0.4 0 0.4 0.4 252 7 254 305 0 0 0 0 -5.6 0 -5.1 -5.8 11/15/2004 18:20:00 6.7 0.8 9.1 4.2 5.4 0.9 7.6 3 0.4 0 0.4 0.4 271 8 275 305 0 0 0 0 -5.9 0.1 -5.3 -6.2 11/15/2004 18:30:00 6.3 1.2 8.8 3.8 5.1 1 8.4 2.6 0.4 0 0.4 0.4 270 10 266 305 0 0 0 0 -6 0 -5.6 -6.2 11/15/2004 18:40:00 6.7 1 8.8 4.2 5.7 1.1 8.8 3 0.4 0 0.4 0.4 272 11 279 305 0 0 0 0 -5.9 0 -5.3 -6 11/15/2004 18:50:00 6.3 1 8.4 3.4 5.3 0.8 7.2 2.6 0.4 0 0.4 0.4 272 12 272 305 0 0 0 0 -5.8 0 -5.6 -6 11/15/2004 19:00:00 6.3 1 8.4 3 5.2 0.8 7.6 3 0.4 0 0.4 0.4 271 10 272 305 0 0 0 0 -5.8 0.1 -5.3 -6 11/15/2004 19:10:00 6.5 1.2 9.5 3.4 5.2 1.1 8.8 2.6 0.4 0 0.4 0.4 270 9 291 305 0 0 0 0 -5.9 0 -5.6 -6 11/15/2004 19:20:00 7.6 1 9.9 5.3 6.3 1 8.8 3.8 0.4 0 0.4 0.4 274 7 278 305 0 0 0 0 -6 0 -5.6 -6.2 11/15/2004 19:30:00 7.7 1.1 9.9 4.2 6.2 1.1 8.8 3 0.4 0 0.4 0.4 273 8 273 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/15/2004 19:40:00 7.5 1 9.9 4.6 5.9 0.9 8.4 3.4 0.4 0 0.4 0.4 268 9 280 305 0 0 0 0 -6 0 -5.6 -6 11/15/2004 19:50:00 8.2 0.9 10.7 6.1 6.9 0.8 9.9 4.9 0.4 0 0.4 0.4 273 9 268 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/15/2004 20:00:00 8.4 1.1 11.1 5.7 6.8 1 9.5 4.2 0.4 0 0.4 0.4 268 8 270 305 0 0 0 0 -6.1 0 -6 -6.2 11/15/2004 20:10:00 8.4 1 11.1 5.3 7 1.1 10.7 4.6 0.4 0 0.4 0.4 263 9 250 305 0 0 0 0 -6.1 0 -6 -6.2 11/15/2004 20:20:00 8.7 1.1 11.1 6.1 7.4 1 9.9 4.9 0.4 0 0.4 0.4 260 8 271 305 0 0 0 0 -6 0 -5.8 -6 11/15/2004 20:30:00 8.3 1.2 11.5 4.9 6.7 1.1 9.9 4.2 0.4 0 0.4 0.4 265 7 258 305 0 0 0 0 -6.1 0 -6 -6.2 11/15/2004 20:40:00 9 1.2 11.8 6.5 7.8 1.2 11.5 4.6 0.4 0 0.4 0.4 256 8 269 305 0 0 0 0 -6 0 -5.8 -6.2 11/15/2004 20:50:00 9.6 1.3 12.2 6.5 8.7 1.3 11.8 4.9 0.4 0 0.4 0.4 251 8 255 305 0 0 0 0 -5.9 0 -5.8 -6 11/15/2004 21:00:00 9.8 1.3 12.6 6.1 9 1.5 12.2 5.3 0.4 0 0.7 0.4 247 8 243 305 0 0 0 0 -5.8 0 -5.3 -6 11/15/2004 21:10:00 9.9 1.6 13.3 6.1 8.9 1.7 13.3 4.9 0.4 0 0.4 0.4 251 9 248 305 0 0 0 0 -5.8 0 -5.6 -6 11/15/2004 21:20:00 11.8 1.7 15.3 6.5 9.8 1.7 13.7 4.9 0.4 0 0.4 0.4 258 6 262 305 0 0 0 0 -6 0 -5.3 -6.2 11/15/2004 21:30:00 11.8 1.2 14.5 8.4 9.8 1.3 13.7 6.5 0.4 0 0.4 0.4 258 6 253 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/15/2004 21:40:00 12 1.2 15.3 8.4 10.6 1.4 13.7 6.1 0.4 0 0.4 0.4 253 6 251 305 0 0 0 0 -6.2 0 -5.8 -6.2 11/15/2004 21:50:00 10.9 1.4 14.9 7.6 10.1 1.5 14.5 6.8 0.4 0 0.4 0.4 250 6 251 305 0 0 0 0 -6.2 0 -5.8 -6.4 11/15/2004 22:00:00 11.5 1.6 15.6 6.1 10.2 1.9 14.5 5.3 0.4 0 0.4 0.4 254 7 247 305 0 0 0 0 -6.3 0.1 -5.6 -6.7 11/15/2004 22:10:00 10.3 1.2 13.7 7.2 8.8 1.5 13 5.3 0.4 0 0.4 0.4 255 8 249 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/15/2004 22:20:00 9.1 1.5 13 5.7 8.4 1.6 12.2 4.2 0.4 0 0.4 0.4 251 10 258 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/15/2004 22:30:00 10.4 1.4 13.7 6.8 9.3 1.7 13.3 5.7 0.4 0 0.4 0.4 255 6 252 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/15/2004 22:40:00 9 1.2 11.5 5.7 8.3 1.2 11.1 4.9 0.4 0 0.4 0.4 249 6 250 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/15/2004 22:50:00 8 1 9.9 5.3 7.2 1.1 9.9 4.6 0.4 0 0.4 0.4 251 7 240 305 0 0 0 0 -6.2 0 -6 -6.4 11/15/2004 23:00:00 7.9 1 10.3 5.3 6.8 1.1 9.5 3.8 0.4 0 0.4 0.4 256 14 263 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/15/2004 23:10:00 8.2 1.1 11.1 5.3 6.5 1.1 9.1 4.2 0.4 0 0.4 0.4 263 6 264 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/15/2004 23:20:00 7.6 1.4 11.1 4.6 6.3 1.3 9.9 3 0.4 0 0.4 0.4 261 8 257 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/15/2004 23:30:00 7.6 1 10.7 4.6 6.6 1 9.1 3.4 0.4 0 0.4 0.4 256 6 256 305 0 0 0 0 -6.4 0.1 -5.8 -6.7 11/15/2004 23:40:00 7.8 0.9 10.3 4.6 7.1 1 9.5 4.2 0.4 0 0.4 0.4 252 7 261 305 0 0 0 0 -6.4 0.1 -5.8 -6.7 11/15/2004 23:50:00 6.3 0.9 8.8 3.8 5.7 1 8.4 3.4 0.4 0 0.4 0.4 249 9 251 305 0 0 0 0 -6.4 0 -6 -6.7 11/16/2004 00:00:00 7.1 1.1 10.3 4.6 6.4 1.1 9.1 3 0.4 0 0.4 0.4 247 8 257 305 0 0 0 0 -6.3 0 -5.8 -6.7 11/16/2004 00:10:00 6.8 1.2 9.5 3.8 6.2 1.2 8.4 3.4 0.4 0 0.4 0.4 243 8 259 305 0 0 0 0 -6.4 0.1 -5.8 -6.7 11/16/2004 00:20:00 7.3 1.1 9.9 4.2 6.4 1.2 9.5 3.4 0.4 0 0.4 0.4 251 8 253 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/16/2004 00:30:00 7.5 0.9 9.9 4.6 6.5 1.1 9.5 4.2 0.4 0 0.4 0.4 256 8 263 305 0 0 0 0 -6.5 0 -6 -6.7 11/16/2004 00:40:00 7.6 0.9 9.5 4.9 6.6 1.1 9.9 3.8 0.4 0 0.4 0.4 258 8 259 305 0 0 0 0 -6.4 0.1 -5.8 -6.7 11/16/2004 00:50:00 8.1 1.3 12.6 4.9 6.7 1.3 10.7 3.4 0.4 0 0.4 0.4 259 9 262 305 0 0 0 0 -6.4 0.1 -5.8 -6.7 11/16/2004 01:00:00 8.4 1.2 11.1 4.9 6.6 1 9.1 3 0.4 0 0.4 0.4 263 7 269 305 0 0 0 0 -6.5 0.1 -6 -6.7 11/16/2004 01:10:00 8.4 0.9 10.7 5.7 6.9 1 9.9 3.8 0.4 0 0.4 0.4 261 6 265 305 0 0 0 0 -6.4 0 -6 -6.7 11/16/2004 01:20:00 8.3 1 11.1 5.7 7.4 1.2 10.3 4.2 0.4 0 0.4 0.4 255 7 256 305 0 0 0 0 -6.5 0 -6 -6.7 11/16/2004 01:30:00 8.3 1.2 11.8 5.3 7.3 1.4 10.7 4.6 0.4 0 0.4 0.4 254 8 254 305 0 0 0 0 -6.4 0.1 -5.8 -6.7 11/16/2004 01:40:00 8.8 1.1 11.5 5.7 7.6 1.2 11.5 4.6 0.4 0 0.4 0.4 257 6 254 305 0 0 0 0 -6.5 0 -5.8 -6.7 11/16/2004 01:50:00 8.4 1.3 11.1 5.3 7.3 1.3 10.3 3.8 0.4 0 0.4 0.4 255 9 268 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/16/2004 02:00:00 9.9 1.4 13.3 6.1 8.2 1.3 10.7 4.6 0.4 0 0.4 0.4 261 6 261 305 0 0 0 0 -6.4 0 -5.8 -6.4 11/16/2004 02:10:00 9.6 1 12.2 6.5 8.1 1.3 11.5 4.9 0.4 0 0.4 0.4 259 7 262 305 0 0 0 0 -6.4 0 -6 -6.7 11/16/2004 02:20:00 9.7 1 11.8 6.5 7.9 1.2 11.8 4.6 0.4 0 0.4 0.4 263 8 251 305 0 0 0 0 -6.5 0 -6 -6.7 11/16/2004 02:30:00 10.3 1 12.6 7.6 8.9 1.2 11.5 6.1 0.4 0 0.4 0.4 258 6 260 305 0 0 0 0 -6.8 0.1 -6 -7.1 11/16/2004 02:40:00 9.9 1.4 12.6 6.1 8.5 1.4 11.8 4.9 0.4 0 0.4 0.4 256 7 266 305 0 0 0 0 -6.8 0 -6.2 -6.9 11/16/2004 02:50:00 10.3 1 13 7.6 9.3 1 11.8 6.1 0.4 0 0.7 0.4 251 8 261 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/16/2004 03:00:00 9.4 1.2 13.3 6.1 8.3 1.5 13.3 4.2 0.4 0 0.4 0.4 254 8 248 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/16/2004 03:10:00 10.3 1.3 12.6 6.5 8.7 1.4 11.8 5.3 0.4 0 0.4 0.4 259 7 266 305 0 0 0 0 -6.7 0 -6.7 -6.9 11/16/2004 03:20:00 9.3 1.1 12.6 6.1 8 1.4 12.2 4.9 0.4 0 0.4 0.4 254 10 242 305 0 0 0 0 -6.6 0.1 -6.2 -6.9 11/16/2004 03:30:00 9.2 1.3 12.2 5.3 8.1 1.3 11.8 3.8 0.4 0 0.4 0.4 254 7 247 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/16/2004 03:40:00 10.4 1.7 13.3 6.1 9.5 1.8 13 4.9 0.4 0 0.4 0.4 250 7 254 305 0 0 0 0 -6.3 0.1 -6 -6.7 11/16/2004 03:50:00 9.3 1.1 11.5 6.1 8 1.3 10.7 4.6 0.4 0 0.4 0.4 254 10 238 305 0 0 0 0 -6.3 0 -6.2 -6.4 11/16/2004 04:00:00 7.7 0.9 10.3 5.3 6.4 1 9.1 3.8 0.4 0 0.4 0.4 259 8 261 305 0 0 0 0 -6.2 0 -6 -6.4 11/16/2004 04:10:00 9 0.9 11.1 6.5 7.9 1 10.3 4.9 0.4 0 0.4 0.4 255 7 259 305 0 0 0 0 -6.2 0 -5.8 -6.4 11/16/2004 04:20:00 9.1 0.8 11.5 6.8 8.4 1 11.1 5.3 0.4 0 0.4 0.4 243 6 246 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/16/2004 04:30:00 9.4 1.1 12.2 6.8 8.5 1.3 11.5 4.9 0.4 0 0.4 0.4 243 7 234 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/16/2004 04:40:00 9.6 0.9 11.8 7.2 8.9 1 11.5 6.5 0.4 0 0.4 0.4 241 6 239 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/16/2004 04:50:00 8.2 1.1 10.3 4.9 7.2 1 9.9 4.2 0.4 0 0.4 0.4 251 11 261 305 0 0 0 0 -6.5 0.2 -5.8 -6.9 11/16/2004 05:00:00 7.7 1.3 11.1 4.9 7 1.5 10.7 4.2 0.4 0 0.4 0.4 244 7 256 305 0 0 0 0 -6.8 0.1 -6.4 -7.1 11/16/2004 05:10:00 7.8 1.3 9.9 4.2 7.2 1.3 10.3 3.8 0.4 0 0.4 0.4 244 8 229 305 0 0 0 0 -6.5 0.1 -6.2 -6.9 11/16/2004 05:20:00 7.5 1 9.9 4.6 7 1.1 9.9 4.2 0.4 0 0.4 0.4 243 7 235 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/16/2004 05:30:00 8.9 1.5 12.2 5.3 7.5 1.5 12.2 4.2 0.4 0 0.4 0.4 260 8 246 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/16/2004 05:40:00 10 1 12.2 7.2 8.9 1.2 12.2 4.9 0.4 0 0.4 0.4 252 7 256 305 0 0 0 0 -6 0 -5.8 -6.2 11/16/2004 05:50:00 11.1 1.5 14.5 6.8 9.6 1.7 14.5 4.9 0.4 0 0.7 0.4 257 8 256 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/16/2004 06:00:00 11.4 1.5 14.5 7.2 9.9 1.6 14.1 6.1 0.4 0 0.4 0.4 257 7 252 305 0 0 0 0 -6.3 0 -6.2 -6.7 11/16/2004 06:10:00 11.5 1.6 15.3 7.2 9.9 1.7 14.9 5.7 0.4 0 0.4 0.4 254 7 254 305 0 0 0 0 -6.2 0 -6 -6.4 11/16/2004 06:20:00 12.3 1.6 15.3 6.8 10.9 1.8 14.9 5.3 0.4 0 0.4 0.4 255 7 258 305 0 0 0 0 -6.2 0 -6 -6.2 11/16/2004 06:30:00 12.5 1.6 17.2 7.6 11.2 1.7 16.4 7.2 0.4 0 0.4 0.4 254 8 259 305 0 0 0 0 -6.2 0 -6 -6.4 11/16/2004 06:40:00 11.6 1.7 15.6 6.8 9.7 2 15.3 4.9 0.4 0 0.4 0.4 263 9 247 305 0 0 0 0 -6.5 0.2 -6.2 -7.1 11/16/2004 06:50:00 9.5 1 11.8 6.8 8 1.1 11.5 5.3 0.4 0 0.4 0.4 257 7 250 305 0 0 0 0 -7.1 0.1 -6.7 -7.5 11/16/2004 07:00:00 9.6 1.6 13.7 5.7 8.6 1.5 12.2 4.6 0.4 0 0.4 0.4 248 9 230 305 0 0 0 0 -6.9 0.2 -6.7 -7.1 11/16/2004 07:10:00 11.2 1.4 14.1 6.8 9.6 1.5 12.6 4.6 0.4 0 0.7 0.4 255 7 257 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/16/2004 07:20:00 11.3 1.3 13.7 8 10.2 1.5 13.7 6.1 0.4 0 0.4 0.4 252 5 246 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/16/2004 07:30:00 9.8 1.5 14.5 6.5 8.7 1.7 13.3 5.3 0.4 0 0.4 0.4 251 9 251 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/16/2004 07:40:00 11 1.5 14.9 6.1 9.7 1.7 14.5 5.7 0.4 0 0.4 0.4 254 8 251 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/16/2004 07:50:00 9.8 1.2 14.5 7.2 9.2 1.3 13.7 6.5 0.4 0 0.4 0.4 238 7 242 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/16/2004 08:00:00 9.8 1.2 12.2 6.8 9.2 1.2 11.8 5.3 0.4 0 0.4 0.4 237 7 241 305 0 0 0 0 -6.6 0 -6.4 -6.7 11/16/2004 08:10:00 10.6 1.4 13.3 6.5 9.9 1.4 13 5.3 0.4 0 0.4 0.4 238 9 233 305 0 0 0 0 -6.5 0 -6 -6.7 11/16/2004 08:20:00 10.8 1.2 13.7 6.5 10.1 1.3 13.3 5.7 0.4 0 0.4 0.4 246 7 240 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/16/2004 08:30:00 9.9 1.3 13.3 6.5 8.8 1.5 13.3 5.3 0.4 0 0.4 0.4 250 9 252 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/16/2004 08:40:00 9.1 1.4 11.8 4.9 8 1.4 11.8 4.6 0.4 0 0.4 0.4 255 8 245 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/16/2004 08:50:00 11.2 1.3 14.9 6.5 9.6 1.4 13.7 6.5 0.4 0 0.4 0.4 257 5 258 305 0 0 0 0 -6.5 0 -6.2 -6.7 11/16/2004 09:00:00 9.5 1.3 13 4.9 8.6 1.3 13.3 5.3 0.4 0 0.4 0.4 251 7 251 305 0 0 0 0 -6.5 0 -6.4 -6.9 11/16/2004 09:10:00 10 1.5 13 6.5 8.6 1.5 12.2 5.3 0.4 0 0.4 0.4 256 7 258 305 0 0 0 0 -6.3 0 -6.2 -6.4 11/16/2004 09:20:00 9.7 1.9 13.3 5.3 8 1.5 11.8 4.6 0.4 0 0.4 0.4 259 7 260 305 0 0 0 0 -6.2 0 -6 -6.4 11/16/2004 09:30:00 10.4 1 12.6 7.6 9.6 1.3 12.6 6.5 0.4 0 0.4 0.4 248 8 261 305 0 0 0 0 -6.3 0.1 -6 -6.4 11/16/2004 09:40:00 10.4 1.1 13.3 7.6 9.7 1.1 12.6 6.5 0.4 0 0.4 0.4 242 6 238 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/16/2004 09:50:00 9.4 1.3 13 6.5 8.5 1.4 12.6 5.3 0.4 0 0.4 0.4 250 8 244 305 0 0 0 0 -6.2 0 -6 -6.4 11/16/2004 10:00:00 11.3 1.6 14.5 6.8 10.3 1.7 13.7 5.3 0.4 0 0.4 0.4 253 6 258 305 0 0 0 0 -6.2 0 -5.8 -6.2 11/16/2004 10:10:00 10.7 1.7 13.7 5.7 9.4 1.6 14.1 5.7 0.4 0 0.4 0.4 257 7 251 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/16/2004 10:20:00 9.7 1.3 12.6 5.7 8.3 1.4 12.6 5.3 0.4 0 0.4 0.4 256 9 252 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/16/2004 10:30:00 9.3 1.5 12.2 5.7 8.5 1.7 11.8 4.6 0.4 0 0.4 0.4 250 10 245 305 0 0 0 0 -6.2 0 -5.8 -6.2 11/16/2004 10:40:00 9.5 1.3 13.7 6.1 8 1.3 12.6 5.3 0.4 0 0.4 0.4 258 8 279 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/16/2004 10:50:00 9 1.3 12.6 5.7 7.9 1.7 11.5 3.8 0.4 0 0.4 0.4 256 8 251 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/16/2004 11:00:00 8.5 1.2 11.8 4.6 7.7 1.3 11.5 4.2 0.4 0 0.4 0.4 253 10 251 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/16/2004 11:10:00 9.5 1.1 12.6 6.8 8.5 1.3 12.6 4.6 0.4 0 0.4 0.4 252 6 252 305 0 0 0 0 -6 0 -5.8 -6.2 11/16/2004 11:20:00 9.5 0.8 11.8 7.2 8.2 0.9 10.3 5.7 0.4 0 0.4 0.4 253 9 256 305 0 0 0 0 -6.1 0 -5.6 -6.2 11/16/2004 11:30:00 8.8 1.1 11.5 5.7 8.1 1.3 11.5 4.9 0.4 0 0.4 0.4 248 8 250 305 0 0 0 0 -6.1 0 -6 -6.2 11/16/2004 11:40:00 10.3 1.2 13.3 6.8 9.6 1.1 12.6 6.5 0.4 0 0.4 0.4 244 8 238 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/16/2004 11:50:00 10.2 1.5 13 5.7 9.4 1.7 12.2 4.6 0.4 0 0.4 0.4 248 9 239 305 0 0 0 0 -6.2 0 -6 -6.2 11/16/2004 12:00:00 9.9 1.4 12.6 5.7 9 1.5 12.6 5.3 0.4 0 0.7 0.4 250 8 250 305 0 0 0 0 -6 0 -5.8 -6.2 11/16/2004 12:10:00 9 1.2 11.8 6.5 8 1.4 11.5 4.2 0.4 0 0.4 0.4 250 8 255 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/16/2004 12:20:00 8.6 0.9 11.1 6.1 7.9 1 11.1 5.3 0.4 0 0.4 0.4 247 7 245 305 0 0 0 0 -6.1 0 -5.8 -6.2 11/16/2004 12:30:00 9 1.5 12.6 5.3 7.9 1.5 12.2 4.9 0.4 0 0.4 0.4 254 11 251 305 0 0 0 0 -6 0 -5.8 -6.2 11/16/2004 12:40:00 9.2 1.1 11.5 5.7 7.8 1.3 10.7 4.2 0.4 0 0.4 0.4 259 6 256 305 0 0 0 0 -6 0 -5.8 -6.2 11/16/2004 12:50:00 8.5 1.3 11.8 5.3 7.7 1.4 11.8 4.9 0.4 0 0.4 0.4 247 8 245 305 0 0 0 0 -6.1 0 -6 -6.2 11/16/2004 13:00:00 8.6 0.9 10.7 5.7 8 1.1 10.7 5.3 0.4 0 0.4 0.4 247 6 256 305 0 0 0 0 -6.3 0 -6 -6.4 11/16/2004 13:10:00 9.1 1.2 11.5 6.5 8 1.3 11.1 4.9 0.4 0 0.4 0.4 253 7 261 305 0 0 0 0 -6.2 0 -6 -6.2 11/16/2004 13:20:00 8.4 1.1 10.3 5.3 7.2 1 9.1 4.2 0.4 0 0.4 0.4 256 8 266 305 0 0 0 0 -6.1 0 -6 -6.2 11/16/2004 13:30:00 9.2 1 11.1 5.7 7.8 1 10.3 5.3 0.4 0 0.7 0.4 250 16 262 305 0 0 0 0 -5.9 0.1 -5.6 -6.2 11/16/2004 13:40:00 9 1.3 13.3 5.7 8.5 1.3 12.6 4.9 0.4 0 0.4 0.4 232 7 238 305 0 0 0 0 -5.8 0 -5.6 -5.8 11/16/2004 13:50:00 7.8 0.7 9.5 5.3 6.9 1 9.5 4.2 0.4 0 0.4 0.4 254 9 264 305 0 0 0 0 -5.8 0 -5.6 -6 11/16/2004 14:00:00 8.1 1.3 11.1 4.6 7.5 1.2 10.7 4.2 0.4 0 0.4 0.4 248 6 252 305 0 0 0 0 -5.9 0.1 -5.6 -6 11/16/2004 14:10:00 7.8 0.9 9.9 5.3 6.7 1 9.1 4.2 0.4 0 0.4 0.4 252 13 263 305 0 0 0 0 -5.8 0 -5.6 -6 11/16/2004 14:20:00 9 0.8 10.7 6.8 8.3 1 10.7 4.9 0.4 0 0.4 0.4 242 8 244 305 0 0 0 0 -5.6 0 -5.6 -5.8 11/16/2004 14:30:00 8.7 1.1 11.1 4.6 8 1.2 11.1 4.9 0.4 0 0.4 0.4 240 10 242 305 0 0 0 0 -5.8 0.1 -5.6 -6 11/16/2004 14:40:00 7.2 1 9.5 4.9 6.7 1 9.5 4.9 0.4 0 0.4 0.4 236 15 255 305 0 0 0 0 -5.9 0.1 -5.6 -6 11/16/2004 14:50:00 7.6 1.3 11.1 4.6 7 1.4 10.3 4.2 0.4 0 0.4 0.4 251 6 248 305 0 0 0 0 -5.8 0 -5.6 -6 11/16/2004 15:00:00 7.4 1.4 11.5 4.6 6.8 1.4 11.1 4.2 0.4 0 0.4 0.4 242 8 246 305 0 0 0 0 -5.9 0 -5.8 -6 11/16/2004 15:10:00 7.4 1 9.9 5.3 6.6 1.1 9.9 4.6 0.4 0 0.4 0.4 245 12 240 305 0 0 0 0 -5.8 0 -5.6 -6 11/16/2004 15:20:00 6.5 1.1 8.8 3 5.6 1.1 8.4 2.6 0.4 0 0.4 0.4 257 9 239 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/16/2004 15:30:00 6.5 0.9 9.1 3.8 5.8 1.1 8.8 3 0.4 0 0.4 0.4 254 8 249 305 0 0 0 0 -5.7 0 -5.6 -5.8 11/16/2004 15:40:00 6.7 0.7 8 4.9 6.1 0.8 8.4 3.8 0.4 0 0.4 0.4 248 7 251 305 0 0 0 0 -5.8 0 -5.6 -5.8 11/16/2004 15:50:00 5.7 0.7 7.2 3.8 5.1 0.8 6.8 3 0.4 0 0.4 0.4 250 8 259 305 0 0 0 0 -5.8 0 -5.6 -6 11/16/2004 16:00:00 6.7 0.8 8.8 4.2 6.1 0.9 8.4 4.2 0.4 0 0.4 0.4 251 7 254 305 0 0 0 0 -5.5 0 -5.6 -5.8 11/16/2004 16:10:00 6.9 1 9.1 4.6 6.2 0.9 8.8 3.8 0.4 0 0.4 0.4 251 7 250 305 0 0 0 0 -5.5 0 -5.6 -5.6 11/16/2004 16:20:00 6.9 1 9.5 3.8 6.3 1.1 9.1 3 0.4 0 0.4 0.4 252 7 252 305 0 0 0 0 -5.5 0 -5.1 -5.6 11/16/2004 16:30:00 6.5 1.2 8.4 3.8 5.6 1.2 8 2.6 0.4 0 0.4 0.4 260 8 259 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/16/2004 16:40:00 5.1 1 7.6 3.4 4.4 1.1 7.6 2.3 0.4 0 0.4 0.4 261 9 251 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/16/2004 16:50:00 5.1 0.6 6.5 3.4 4.6 0.7 6.5 2.6 0.4 0 0.4 0.4 251 7 246 305 0 0 0 0 -5.5 0 -5.6 -5.6 11/16/2004 17:00:00 5.3 0.7 6.8 3.8 4.3 0.6 6.1 2.6 0.4 0 0.4 0.4 262 7 261 305 0 0 0 0 -5.5 0 -5.6 -5.6 11/16/2004 17:10:00 4.1 0.6 6.1 2.6 3.8 0.6 5.7 2.3 0.4 0 0.4 0.4 245 9 241 305 0 0 0 0 -5.5 0 -5.6 -5.6 11/16/2004 17:20:00 4.5 0.7 6.1 2.6 4.3 0.6 5.7 2.3 0.4 0 0.4 0.4 240 11 233 305 0 0 0 0 -5.4 0 -5.3 -5.6 11/16/2004 17:30:00 5.1 0.8 7.2 3 4.6 1 6.8 2.6 0.4 0 0.4 0.4 254 7 252 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/16/2004 17:40:00 4.9 0.6 6.5 3 4.2 0.8 6.1 2.3 0.4 0 0.4 0.4 258 9 256 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/16/2004 17:50:00 4.1 0.6 6.1 2.6 3.8 0.7 5.3 2.3 0.4 0 0.4 0.4 249 7 248 305 0 0 0 0 -5.4 0 -5.3 -5.6 11/16/2004 18:00:00 3.3 0.5 4.9 2.3 2.9 0.5 4.2 1.5 0.4 0 0.4 0.4 252 8 232 305 0 0 0 0 -5.5 0 -4.9 -5.6 11/16/2004 18:10:00 4.1 0.4 4.9 3 4 0.4 4.9 3 0.4 0 0.4 0.4 238 6 242 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/16/2004 18:20:00 3 0.7 4.6 1.5 2.9 0.6 4.2 1.5 0.4 0 0.4 0.4 235 11 242 305 0 0 0 0 -5.4 0 -5.1 -5.6 11/16/2004 18:30:00 2.2 0.5 3.4 0.7 2.3 0.4 3.4 1.1 0.4 0 0.4 0.4 213 6 214 305 0 0 0 0 -5.5 0 -5.3 -5.6 11/16/2004 18:40:00 3.2 0.8 4.9 0.7 3.6 0.6 4.9 2.3 0.4 0 0.4 0.4 169 23 158 305 0 0 0 0 -5.7 0.2 -5.6 -6.2 11/16/2004 18:50:00 4.4 0.8 5.7 2.3 4.7 0.7 5.7 2.6 0.4 0 0.4 0.4 153 3 146 305 0 0 0 0 -6.4 0.1 -6.2 -6.7 11/16/2004 19:00:00 4.2 0.6 5.7 2.6 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 157 3 156 305 0 0 0 0 -6.6 0 -6.2 -6.7 11/16/2004 19:10:00 4.5 0.6 5.7 2.6 4.8 0.3 5.7 4.2 0.4 0 0.4 0.4 155 5 155 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/16/2004 19:20:00 4.1 0.6 5.3 2.6 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 149 5 154 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/16/2004 19:30:00 4.8 0.5 6.1 3.8 4.9 0.4 5.7 4.2 0.4 0 0.4 0.4 148 3 149 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/16/2004 19:40:00 4.3 0.4 4.9 3.4 4.5 0.3 5.3 3.8 0.4 0 0.4 0.4 145 4 140 305 0 0 0 0 -6.5 0 -6.4 -6.7 11/16/2004 19:50:00 3.8 0.7 5.3 2.6 4 0.7 5.7 2.3 0.4 0 0.4 0.4 140 3 144 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/16/2004 20:00:00 4.3 0.8 6.1 3 4.3 0.8 6.1 3 0.4 0 0.4 0.4 142 6 146 305 0 0 0 0 -6.3 0 -5.8 -6.4 11/16/2004 20:10:00 4.4 0.3 5.3 3 4.3 0.3 4.9 3.4 0.4 0 0.4 0.4 146 4 148 305 0 0 0 0 -6.3 0 -5.8 -6.7 11/16/2004 20:20:00 3.6 0.4 4.2 2.3 3.7 0.4 4.6 2.6 0.4 0 0.4 0.4 128 7 138 305 0 0 0 0 -6.5 0 -6 -6.7 11/16/2004 20:30:00 4.3 0.3 4.9 3 4.4 0.4 5.3 3.4 0.4 0 0.4 0.4 134 3 132 305 0 0 0 0 -6.7 0 -6 -6.9 11/16/2004 20:40:00 4.4 0.3 4.9 3.8 4.5 0.3 5.3 3.8 0.4 0 0.4 0.4 133 3 136 305 0 0 0 0 -6.7 0 -6.2 -6.9 11/16/2004 20:50:00 4.3 0.4 4.9 3.4 4.4 0.3 4.9 3.8 0.4 0 0.4 0.4 135 4 141 305 0 0 0 0 -6.7 0 -6.2 -6.9 11/16/2004 21:00:00 4.3 0.4 4.9 3 4.4 0.3 5.3 3.4 0.4 0 0.4 0.4 125 4 130 305 0 0 0 0 -6.7 0 -6.4 -6.9 11/16/2004 21:10:00 4.2 0.4 5.3 3 4.3 0.3 5.3 3.4 0.4 0 0.4 0.4 126 5 126 305 0 0 0 0 -6.5 0 -6 -6.7 11/16/2004 21:20:00 4.8 0.3 5.3 3.8 4.8 0.3 5.7 4.2 0.4 0 0.4 0.4 131 3 133 305 0 0 0 0 -6.4 0 -6.2 -6.7 11/16/2004 21:30:00 4.1 0.5 5.3 2.6 4.1 0.4 5.3 3 0.4 0 0.4 0.4 122 5 124 305 1 0 0 0 -6.5 0 -6.4 -6.7 11/16/2004 21:40:00 4.7 0.4 5.7 3.4 4.7 0.4 6.1 3.8 0.4 0 0.4 0.4 119 5 113 305 1 0 1 0 -6.4 0.1 -6 -6.7 11/16/2004 21:50:00 5 0.5 6.1 3.4 5.1 0.5 6.1 3.4 0.4 0 0.4 0.4 124 6 117 305 1 0 1 0 -6.1 0 -5.8 -6.2 11/16/2004 22:00:00 4.8 0.6 6.8 3.4 4.9 0.6 6.5 3 0.4 0 0.4 0.4 122 6 121 305 1 0 1 0 -5.8 0 -5.6 -6 11/16/2004 22:10:00 4.5 0.6 6.1 2.6 4.6 0.5 5.7 3 0.4 0 0.4 0.4 119 8 112 305 1 0 0 0 -5.5 0 -5.3 -5.8 11/16/2004 22:20:00 3.9 0.6 5.7 2.6 3.9 0.6 5.7 2.6 0.4 0 0.4 0.4 117 9 127 305 1 0 0 0 -5.3 0 -5.1 -5.6 11/16/2004 22:30:00 3.6 0.6 5.3 1.9 3.7 0.6 5.3 2.3 0.4 0 0.4 0.4 113 9 108 305 1 0 1 0 -5.2 0 -5.1 -5.6 11/16/2004 22:40:00 5.1 0.9 7.2 3 5.2 0.9 7.2 3.4 0.4 0 0.4 0.4 115 11 120 305 1 0 1 0 -5 0 -4.7 -5.1 11/16/2004 22:50:00 5.5 0.8 7.2 3.4 5.4 0.8 7.2 3 0.4 0 0.4 0.4 117 9 116 305 1 0 1 0 -4.7 0 -4.7 -4.9 11/16/2004 23:00:00 5.6 0.9 8.4 3.8 5.6 0.9 8.4 3.4 0.4 0 0.4 0.4 115 11 122 305 1 0 1 0 -4.6 0 -4 -4.7 11/16/2004 23:10:00 5.7 0.8 7.2 3.8 5.7 0.8 7.2 3.8 0.4 0 0.4 0.4 119 7 118 305 1 0 1 0 -4.5 0 -4.5 -4.7 11/16/2004 23:20:00 5.7 0.8 8 3 5.7 0.8 7.6 3.4 0.4 0 0.4 0.4 121 9 117 305 1 0 1 0 -4.5 0 -4.5 -4.7 11/16/2004 23:30:00 5.7 0.9 7.6 3 5.8 1 8.4 3.4 0.4 0 0.4 0.4 118 10 135 305 1 0 1 0 -4.4 0 -4.2 -4.5 11/16/2004 23:40:00 6 0.9 8.4 3.8 6.1 0.9 8.8 3.8 0.4 0 0.4 0.4 128 11 121 305 1 0 1 0 -4.4 0 -4.2 -4.5 11/16/2004 23:50:00 5.9 1 9.1 3.4 5.8 1 8.8 3.4 0.4 0 0.4 0.4 122 10 121 305 1 0 1 0 -4.1 0 -4 -4.5 11/17/2004 00:00:00 5.9 1.2 8.4 3 5.8 1.1 7.6 3.4 0.4 0 0.4 0.4 120 13 111 305 1 0 1 0 -4 0 -3.8 -4 11/17/2004 00:10:00 6.3 1 8.4 3 6.2 1 8.4 1.9 0.4 0 0.4 0.4 118 11 108 305 1 0 1 0 -3.9 0 -3.6 -4 11/17/2004 00:20:00 5.5 0.9 7.6 3.4 5.4 0.8 7.6 3.4 0.4 0 0.4 0.4 110 12 125 305 1 0 1 0 -3.9 0 -3.8 -4 11/17/2004 00:30:00 5 0.9 7.6 2.6 4.9 1 7.6 2.6 0.4 0 0.4 0.4 111 13 113 305 1 0 1 0 -3.8 0 -3.8 -3.8 11/17/2004 00:40:00 5.4 0.9 7.2 3 5.4 0.9 8 3.4 0.4 0 0.4 0.4 105 11 109 305 1 0 1 0 -3.7 0 -3.6 -3.8 11/17/2004 00:50:00 5.4 1 8 3 5.2 0.9 7.6 3 0.4 0 0.4 0.4 97 12 95 305 1 0 1 0 -3.5 0 -3.3 -3.8 11/17/2004 01:00:00 4.9 1.1 8.4 2.3 4.9 1 8.8 3 0.4 0 0.4 0.4 98 18 108 305 1 0 1 0 -3.2 0 -3.1 -3.3 11/17/2004 01:10:00 5.3 1 7.6 3.4 5 1 7.6 3 0.4 0 0.4 0.4 102 18 78 305 1 0 1 0 -3.2 0 -3.1 -3.3 11/17/2004 01:20:00 5.8 1.1 7.6 2.6 5.6 1 8.4 3 0.4 0 0.4 0.4 106 12 125 305 1 0 1 0 -3.1 0 -3.1 -3.3 11/17/2004 01:30:00 6.6 1.3 9.9 3 6.5 1.3 10.7 3.8 0.4 0 0.4 0.4 108 12 111 305 1 0 1 0 -3 0 -2.7 -3.1 11/17/2004 01:40:00 6.6 1.3 9.5 3 6.5 1.1 9.1 3.4 0.4 0 0.4 0.4 111 15 97 305 1 0 1 0 -2.8 0 -2.7 -2.9 11/17/2004 01:50:00 7.5 1.2 10.7 4.2 7.4 1.2 11.5 4.6 0.4 0 0.4 0.4 117 11 147 305 1 0 1 0 -2.7 0 -2.4 -2.7 11/17/2004 02:00:00 7.1 1 9.5 3.8 7 1.1 10.3 4.2 0.4 0 0.4 0.4 116 13 112 305 1 0 1 0 -2.6 0 -2.4 -2.7 11/17/2004 02:10:00 7.5 1.4 10.3 3.4 7.4 1.3 10.3 3.8 0.4 0 0.4 0.4 114 13 125 305 1 0 1 0 -2.6 0 -2.4 -2.7 11/17/2004 02:20:00 7.4 0.9 9.5 4.9 7.3 0.9 9.5 4.6 0.4 0 0.4 0.4 114 13 109 305 1 0 1 0 -2.5 0 -2.4 -2.7 11/17/2004 02:30:00 7.4 1.1 9.5 3.4 7.2 1.2 9.9 4.2 0.4 0 0.4 0.4 114 10 124 305 1 0 1 0 -2.5 0 -2 -2.7 11/17/2004 02:40:00 6.1 1.5 10.7 2.6 5.9 1.5 10.7 2.6 0.4 0 0.4 0.4 112 15 105 305 2 0 2 0 -2.3 0 -2 -2.4 11/17/2004 02:50:00 7 1.4 10.7 3.8 6.7 1.3 10.7 3.8 0.4 0 0.4 0.4 111 15 108 305 2 0 2 0 -2.2 0 -1.8 -2.4 11/17/2004 03:00:00 5.7 1.3 10.7 2.6 5.4 1.2 10.3 3 0.4 0 0.4 0.4 111 17 141 305 2 0 2 0 -2.2 0 -2 -2.4 11/17/2004 03:10:00 6.9 1.3 9.9 3.4 6.6 1.2 9.5 3 0.4 0 0.4 0.4 109 13 102 305 2 0 2 0 -2 0 -1.8 -2.2 11/17/2004 03:20:00 6.9 1.6 11.1 3 6.7 1.5 11.5 3.4 0.4 0 0.4 0.4 112 16 128 305 2 0 2 0 -1.9 0 -1.8 -2 11/17/2004 03:30:00 7.8 1.6 11.1 4.2 7.5 1.6 11.5 4.2 0.4 0 0.4 0.4 109 17 105 305 2 0 2 0 -1.9 0 -1.8 -2 11/17/2004 03:40:00 8.5 1.7 12.6 4.9 8.2 1.7 12.2 4.6 0.4 0 0.4 0.4 109 12 113 305 2 0 2 0 -1.8 0 -1.8 -2 11/17/2004 03:50:00 7.8 1.9 12.2 3.4 7.5 1.8 11.1 3.4 0.4 0 0.4 0.4 102 17 119 305 2 0 2 0 -1.7 0 -1.8 -1.8 11/17/2004 04:00:00 7.3 1.5 10.7 3.4 7 1.3 10.3 3.8 0.4 0 0.4 0.4 108 18 91 305 1 0 1 0 -1.6 0 -1.1 -1.8 11/17/2004 04:10:00 7.8 1.4 12.6 5.3 7.5 1.5 12.2 4.6 0.4 0 0.4 0.4 107 16 90 305 1 0 1 0 -1.5 0.1 -1.1 -1.8 11/17/2004 04:20:00 7.8 2 13.7 3.8 7.3 1.8 13 3.8 0.4 0 0.4 0.4 102 18 93 305 1 0 1 0 -1.4 0 -1.3 -1.5 11/17/2004 04:30:00 9.6 1.8 14.1 4.9 9.1 1.7 13.3 4.9 0.4 0 0.4 0.4 103 16 105 305 1 0 1 0 -1.4 0 -1.1 -1.5 11/17/2004 04:40:00 8 2.2 14.5 3.4 7.7 2.2 13.7 3 0.4 0 0.4 0.4 104 20 113 305 1 0 1 0 -1.2 0 -0.8 -1.3 11/17/2004 04:50:00 8.5 1.7 13.3 4.6 7.9 1.7 12.6 3.8 0.4 0 0.4 0.4 94 19 87 305 1 0 1 0 -1.2 0 -0.8 -1.3 11/17/2004 05:00:00 7.8 2.1 13.3 2.3 7.6 2.1 13.7 2.3 0.4 0 0.4 0.4 86 20 74 305 1 0 1 0 -1.2 0 -0.8 -1.3 11/17/2004 05:10:00 8 1.7 14.1 4.2 7.7 1.9 12.6 2.6 0.4 0 0.4 0.4 89 23 99 305 1 0 1 0 -1.2 0 -0.8 -1.3 11/17/2004 05:20:00 8.9 2.2 14.1 3 8.6 2.2 14.1 3 0.4 0 0.4 0.4 83 22 68 305 1 0 1 0 -1.1 0 -0.6 -1.3 11/17/2004 05:30:00 9.6 2.3 14.5 3 9.4 2.3 14.9 3.8 0.4 0 0.4 0.4 78 18 76 305 1 0 1 0 -1.1 0 -0.6 -1.1 11/17/2004 05:40:00 9.8 2.1 15.3 3.8 9.7 2.2 16.4 4.6 0.4 0 0.4 0.4 72 17 58 305 1 0 1 0 -1 0 -0.6 -1.1 11/17/2004 05:50:00 9.4 2.3 15.6 4.2 9.3 2.5 16.1 3.8 0.4 0 0.4 0.4 75 17 90 305 1 0 1 0 -0.8 0 -0.4 -1.1 11/17/2004 06:00:00 8.6 2.6 15.3 3 8.4 2.7 15.6 2.3 0.4 0 0.4 0.4 80 22 71 305 1 0 1 0 -0.7 0 -0.6 -0.8 11/17/2004 06:10:00 7.4 1.9 12.6 3 7.2 1.9 12.2 3 0.4 0 0.4 0.4 88 24 77 305 1 0 1 0 -0.8 0 -0.4 -1.1 11/17/2004 06:20:00 7.7 2.3 13.7 2.6 7.4 2.2 13.7 1.9 0.4 0 0.4 0.4 83 23 101 305 1 0 1 0 -0.8 0 -0.6 -0.8 11/17/2004 06:30:00 8.8 2.5 15.3 2.6 8.6 2.5 15.3 1.9 0.4 0 0.4 0.4 69 19 54 305 1 0 1 0 -0.7 0 -0.6 -0.8 11/17/2004 06:40:00 9.3 2 14.9 4.9 8.9 2.1 15.3 4.6 0.4 0 0.4 0.4 78 18 85 305 1 0 1 0 -0.7 0 -0.4 -0.8 11/17/2004 06:50:00 10.7 2.6 17.9 4.9 10.5 2.7 16.8 3.8 0.4 0 0.4 0.4 74 17 81 305 1 0 1 0 -0.7 0 -0.1 -0.6 11/17/2004 07:00:00 10.4 2.8 17.9 3.4 10.2 2.8 18.3 4.2 0.4 0 0.4 0.4 79 17 63 305 1 0 1 0 -0.7 0 -0.1 -0.8 11/17/2004 07:10:00 11.8 2.1 18.3 6.5 11.6 2.2 17.9 6.8 0.4 0 0.4 0.4 73 13 83 305 1 0 2 0 -0.7 0 -0.6 -0.8 11/17/2004 07:20:00 11.9 1.7 16.4 6.1 11.5 1.7 16.8 6.5 0.4 0 0.4 0.4 79 11 87 305 1 0 1 0 -0.6 0 0.1 -0.6 11/17/2004 07:30:00 12.2 1.6 15.6 7.6 12 1.7 15.6 6.5 0.4 0 0.4 0.4 75 11 82 305 1 0 1 0 -0.6 0 -0.4 -0.6 11/17/2004 07:40:00 12.6 1.7 17.9 8.4 12.4 1.7 16.8 8 0.4 0 0.4 0.4 79 9 82 305 1 0 2 0 -0.6 0 -0.4 -0.6 11/17/2004 07:50:00 13.1 1.6 18.7 8.8 12.8 1.8 19.5 8 0.4 0 0.4 0.4 78 9 64 305 2 0 2 0 -0.5 0 -0.4 -0.6 11/17/2004 08:00:00 13.9 1.5 17.9 8.4 13.5 1.7 17.6 8 0.4 0 0.4 0.4 77 8 71 305 2 0 2 0 -0.5 0.1 0.1 -0.6 11/17/2004 08:10:00 14.7 2 20.2 9.5 14.3 2.1 20.2 9.1 0.4 0 0.4 0.4 80 9 79 305 2 0 2 0 -0.4 0.1 0.1 -0.6 11/17/2004 08:20:00 14.5 1.6 18.7 9.1 14.2 1.7 19.1 8.8 0.4 0 0.4 0.4 78 9 83 305 2 0 2 0 -0.4 0.1 0.1 -0.6 11/17/2004 08:30:00 14.5 1.7 18.7 8 14.2 1.7 18.3 7.6 0.4 0 0.4 0.4 79 9 92 305 3 0 3 0 -0.4 0.1 0.1 -0.6 11/17/2004 08:40:00 13.8 1.7 18.3 9.1 13.5 1.9 18.3 8 0.4 0 0.4 0.4 81 9 75 305 2 0 2 0 -0.4 0.1 0.1 -0.6 11/17/2004 08:50:00 13.1 1.5 16.8 8.8 12.7 1.5 16.4 9.1 0.4 0 0.4 0.4 80 7 81 305 2 0 2 0 -0.4 0.1 0.1 -0.6 11/17/2004 09:00:00 13.8 1.5 16.8 9.9 13.5 1.5 16.8 9.5 0.4 0 0.4 0.4 80 8 71 305 2 0 2 0 -0.4 0 -0.4 -0.6 11/17/2004 09:10:00 13.8 1.7 18.7 8.4 13.4 1.9 18.7 8.4 0.4 0 0.4 0.4 79 8 82 305 2 0 2 0 -0.4 0 0.1 -0.4 11/17/2004 09:20:00 14.4 1.4 17.9 9.5 14.1 1.4 17.6 10.3 0.4 0 0.4 0.4 78 7 73 305 2 0 2 0 -0.4 0 -0.4 -0.4 11/17/2004 09:30:00 14.6 1.5 19.9 11.1 14.2 1.5 19.1 10.3 0.4 0 0.4 0.4 77 7 58 305 2 0 2 0 -0.4 0 -0.1 -0.4 11/17/2004 09:40:00 15 1.5 19.9 11.5 14.6 1.5 18.7 10.7 0.4 0 0.4 0.4 77 7 72 305 2 0 2 0 -0.4 0 -0.1 -0.4 11/17/2004 09:50:00 15.2 1.6 21 11.5 14.9 1.7 19.9 11.1 0.4 0 0.4 0.4 75 6 78 305 3 0 3 0 -0.4 0 0.3 -0.6 11/17/2004 10:00:00 14.7 1.3 17.6 10.3 14.4 1.5 17.9 10.3 0.4 0 0.4 0.4 74 6 69 305 3 0 3 0 -0.5 0 -0.4 -0.6 11/17/2004 10:10:00 14.7 1.1 17.2 11.8 14.5 1.3 17.6 11.8 0.4 0 0.4 0.4 73 7 67 305 4 0 4 0 -0.4 0 -0.4 -0.6 11/17/2004 10:20:00 15.1 1.3 19.5 10.3 14.6 1.4 17.9 11.1 0.4 0 0.4 0.4 75 7 78 305 4 0 4 0 -0.4 0 -0.4 -0.6 11/17/2004 10:30:00 14.2 1.3 17.6 11.5 13.9 1.4 17.6 11.1 0.4 0 0.4 0.4 74 7 74 305 5 0 5 0 -0.3 0 -0.1 -0.4 11/17/2004 10:40:00 15.2 1.4 19.5 11.1 14.9 1.5 18.7 11.1 0.4 0 0.4 0.4 73 6 75 305 5 0 5 0 -0.3 0 -0.1 -0.4 11/17/2004 10:50:00 15.2 1.5 19.5 11.1 14.9 1.6 19.9 10.7 0.4 0 0.4 0.4 74 7 79 305 5 0 6 0 -0.3 0 -0.1 -0.4 11/17/2004 11:00:00 14.9 1.4 20.6 10.3 14.7 1.4 19.5 11.5 0.4 0 0.4 0.4 74 8 84 305 6 0 6 0 -0.3 0 -0.1 -0.4 11/17/2004 11:10:00 14.4 1.5 17.6 10.3 14.1 1.6 17.9 9.9 0.4 0 0.4 0.4 73 8 80 305 7 0 7 0 -0.3 0 0.1 -0.4 11/17/2004 11:20:00 14.5 1.4 18.7 11.5 14.2 1.4 17.9 11.1 0.4 0 0.4 0.4 75 7 69 305 7 0 7 0 -0.1 0 0.1 -0.4 11/17/2004 11:30:00 15 1.5 19.5 11.1 14.6 1.6 18.7 11.1 0.4 0 0.4 0.4 75 7 75 305 7 0 7 0 -0.1 0 0.1 -0.4 11/17/2004 11:40:00 14.4 1.7 18.3 9.9 14.1 1.9 18.3 10.3 0.4 0 0.4 0.4 75 7 77 305 8 0 8 0 -0.2 0 0.1 -0.4 11/17/2004 11:50:00 14.3 1.5 19.1 11.1 13.9 1.6 19.5 9.5 0.4 0 0.4 0.4 74 7 68 305 8 0 8 0 -0.3 0 -0.1 -0.4 11/17/2004 12:00:00 14.1 1.5 17.2 9.9 13.7 1.6 17.6 8.8 0.4 0 0.4 0.4 75 7 65 305 8 0 8 0 -0.3 0 0.3 -0.4 11/17/2004 12:10:00 14 1.4 18.7 11.1 13.6 1.4 18.7 9.9 0.4 0 0.4 0.4 73 7 75 305 8 0 8 0 -0.2 0 0.1 -0.4 11/17/2004 12:20:00 14.2 1.3 17.6 10.7 13.8 1.4 17.2 9.9 0.4 0 0.4 0.4 71 7 72 305 9 0 8 0 -0.1 0 0.1 -0.4 11/17/2004 12:30:00 14.1 1.3 17.2 10.7 13.8 1.4 17.6 10.3 0.4 0 0.4 0.4 70 6 87 305 9 0 9 0 -0.1 0 0.1 -0.1 11/17/2004 12:40:00 14.4 1.5 17.6 11.5 13.9 1.5 17.6 10.7 0.4 0 0.4 0.4 72 7 79 305 9 0 9 0 0 0 0.1 -0.1 11/17/2004 12:50:00 14.4 1.3 18.3 11.5 14 1.3 17.9 10.3 0.4 0 0.4 0.4 76 8 77 305 9 0 9 0 0 0 0.1 -0.1 11/17/2004 13:00:00 15 1.4 18.3 11.8 14.6 1.5 17.9 11.5 0.4 0 0.4 0.4 75 8 75 305 9 0 9 0 0 0 0.6 0.1 11/17/2004 13:10:00 14.6 1.6 18.3 10.3 14.4 1.7 17.9 10.3 0.4 0 0.4 0.4 75 7 73 305 9 0 9 0 0 0 0.3 0.1 11/17/2004 13:20:00 15.1 1.5 19.1 11.5 14.7 1.6 19.1 10.7 0.4 0 0.4 0.4 74 7 74 305 9 0 9 0 0.1 0 0.3 0.1 11/17/2004 13:30:00 14.6 1.6 19.5 9.9 14.3 1.7 19.5 9.9 0.4 0 0.4 0.4 75 7 71 305 9 0 9 0 0.2 0 0.3 0.1 11/17/2004 13:40:00 14.8 1.5 18.3 11.1 14.4 1.5 18.3 10.7 0.4 0 0.4 0.4 74 7 75 305 9 0 9 0 0.2 0 0.3 0.1 11/17/2004 13:50:00 14.7 1.3 18.3 11.1 14.3 1.4 18.3 11.5 0.4 0 0.4 0.4 73 7 74 305 9 0 9 0 0.1 0 0.6 0.1 11/17/2004 14:00:00 15.3 1.6 19.1 11.1 15 1.7 19.1 10.3 0.4 0 0.4 0.4 73 7 70 305 9 0 9 0 0.1 0 0.3 0.1 11/17/2004 14:10:00 14.3 1.6 17.9 9.9 13.9 1.6 17.9 8.4 0.4 0 0.4 0.4 74 7 75 305 10 0 9 0 0 0 0.3 0.1 11/17/2004 14:20:00 14.9 1.5 19.1 11.5 14.6 1.5 19.9 11.1 0.4 0 0.4 0.4 73 7 58 305 10 0 10 0 0 0 0.3 0.1 11/17/2004 14:30:00 15.1 1.7 22.6 11.1 14.7 1.8 19.5 10.7 0.4 0 0.4 0.4 74 7 75 305 10 0 10 0 0 0 0.1 0.1 11/17/2004 14:40:00 15.9 1.8 20.2 11.5 15.4 2 21.8 11.1 0.4 0 0.4 0.4 75 7 81 305 10 0 10 0 0 0 0.1 0.1 11/17/2004 14:50:00 15.8 2 20.6 10.7 15.5 2.2 21 9.9 0.4 0 0.4 0.4 74 9 71 305 10 0 10 0 0 0 0.3 -0.1 11/17/2004 15:00:00 15.7 2.2 21.8 10.3 15.5 2.4 21.4 10.3 0.4 0 0.4 0.4 73 11 58 305 10 0 10 0 -0.1 0 0.1 -0.1 11/17/2004 15:10:00 14.9 2.7 22.1 7.6 15.1 2.7 22.9 6.5 0.4 0 0.4 0.4 68 13 61 305 10 0 10 0 -0.1 0 0.3 -0.4 11/17/2004 15:20:00 14.8 3.5 24.4 6.8 14.6 3.6 24 6.1 0.4 0 0.4 0.4 72 17 82 305 10 0 10 0 -0.2 0 0.3 -0.4 11/17/2004 15:30:00 14 3.3 25.6 6.5 13.8 3.5 27.5 4.9 0.4 0 0.4 0.4 71 17 93 305 10 0 10 0 -0.3 0 -0.1 -0.4 11/17/2004 15:40:00 14.6 3.2 22.9 6.5 14.2 3.2 22.6 4.9 0.4 0 0.4 0.4 70 15 80 305 10 0 10 0 -0.3 0 -0.1 -0.4 11/17/2004 15:50:00 13.9 3.6 23.3 4.9 13.9 3.6 24.8 4.9 0.4 0 0.4 0.4 78 20 66 305 10 0 10 0 -0.3 0 0.1 -0.4 11/17/2004 16:00:00 12 3.1 21.8 5.7 11.9 3.2 21.8 5.3 0.4 0 0.4 0.4 73 22 99 305 10 0 10 0 -0.1 0 0.1 -0.4 11/17/2004 16:10:00 11.5 3.3 19.5 4.6 11.1 3.5 19.1 3.8 0.4 0 0.7 0.4 82 23 83 305 10 0 10 0 0 0 0.6 0.1 11/17/2004 16:20:00 11.3 3.3 20.2 3.4 11.2 3.3 20.6 3.4 0.4 0 0.4 0.4 72 22 69 305 10 0 10 0 0 0 0.3 -0.1 11/17/2004 16:30:00 9.8 3.1 17.9 2.6 9.6 3.2 18.7 3 0.4 0 0.4 0.4 85 27 77 305 10 0 10 0 -0.1 0 0.1 -0.4 11/17/2004 16:40:00 9.3 2.7 16.4 2.3 9 2.7 17.6 3 0.4 0 0.4 0.4 87 28 93 305 10 0 10 0 -0.3 0 -0.1 -0.4 11/17/2004 16:50:00 9.4 2.4 17.6 3.8 8.9 2.5 16.1 2.3 0.4 0 0.4 0.4 93 27 108 305 10 0 10 0 -0.3 0 0.1 -0.4 11/17/2004 17:00:00 9.6 3.1 17.2 1.9 9.2 2.9 16.4 3 0.4 0 0.4 0.4 85 26 106 305 10 0 10 0 -0.3 0 0.1 -0.4 11/17/2004 17:10:00 10.9 2.8 17.6 3.8 10.5 3.1 17.6 3 0.4 0 0.4 0.4 78 23 71 305 10 0 10 0 -0.3 0 0.3 -0.4 11/17/2004 17:20:00 10.8 2.9 19.1 2.6 10.8 2.9 19.9 5.3 0.4 0 0.4 0.4 78 24 66 305 10 0 9 0 -0.4 0 0.3 -0.4 11/17/2004 17:30:00 11 2.7 18.3 1.9 10.8 2.9 18.7 1.1 0.4 0 0.4 0.4 88 28 63 305 10 0 9 0 -0.5 0 -0.4 -0.6 11/17/2004 17:40:00 10.5 3.3 19.5 3.8 10.4 3.3 19.5 4.2 0.4 0 0.4 0.4 94 22 98 305 10 0 10 0 -0.7 0 -0.6 -0.8 11/17/2004 17:50:00 10.5 3.3 19.5 3 10.1 3.3 20.2 3.8 0.4 0 0.4 0.4 98 29 103 305 10 0 10 0 -0.8 0 -0.6 -1.1 11/17/2004 18:00:00 9.6 3.1 18.3 3 9.3 2.7 17.2 3 0.4 0 0.4 0.4 102 29 115 305 10 0 10 0 -0.9 0 -0.4 -1.1 11/17/2004 18:10:00 11.9 3.5 21 2.3 11.3 3.5 21 1.9 0.4 0 0.4 0.4 106 23 98 305 11 1 12 0 -1 0 -0.8 -1.1 11/17/2004 18:20:00 11.3 3.2 20.2 4.9 10.8 3.1 20.6 4.6 0.4 0 0.4 0.4 109 22 80 305 10 0 11 0 -1 0 -0.8 -1.1 11/17/2004 18:30:00 10 3.1 18.3 3.4 9.7 3.1 21.4 3.8 0.4 0 0.4 0.4 110 22 82 305 10 0 10 0 -1 0 -0.8 -1.1 11/17/2004 18:40:00 12 2.8 21.4 4.6 11.7 2.8 21.8 4.9 0.4 0 0.4 0.4 112 21 131 305 10 0 10 0 -1 0 -0.6 -1.1 11/17/2004 18:50:00 11.6 2.6 18.7 4.6 11.3 2.6 18.3 5.7 0.4 0 0.4 0.4 113 21 107 305 10 0 10 0 -1 0 -0.8 -1.1 11/17/2004 19:00:00 12.6 3.5 21.8 3 12.3 3.3 22.1 5.3 0.4 0 0.4 0.4 116 19 94 305 10 0 10 0 -1.1 0 -0.8 -1.1 11/17/2004 19:10:00 12.3 2.5 20.2 5.7 11.9 2.6 17.9 5.3 0.4 0 0.4 0.4 115 17 123 305 10 0 9 0 -1 0 -0.8 -1.1 11/17/2004 19:20:00 13.1 2.6 19.9 7.2 12.9 2.6 20.6 5.7 0.4 0 0.4 0.4 123 15 127 305 10 0 9 0 -1 0 -0.6 -1.1 11/17/2004 19:30:00 14.1 2.9 21 5.7 13.8 2.8 19.9 6.5 0.4 0 0.4 0.4 120 14 133 305 10 0 10 0 -1 0 -0.8 -1.1 11/17/2004 19:40:00 14.1 2.5 20.2 6.8 13.9 2.4 19.9 6.8 0.4 0 0.4 0.4 121 13 125 305 10 0 10 0 -1 0 -0.8 -1.1 11/17/2004 19:50:00 15.2 2.6 25.6 9.5 14.8 2.5 23.7 9.1 0.4 0 0.4 0.4 119 11 126 305 11 0 11 0 -1 0 -0.8 -1.1 11/17/2004 20:00:00 13 2.5 20.6 6.8 12.6 2.3 19.1 6.8 0.4 0 0.4 0.4 122 13 108 305 13 0 13 0 -1 0 -1.1 -1.1 11/17/2004 20:10:00 12.4 2.4 18.3 7.6 12 2.3 19.1 7.6 0.4 0 0.4 0.4 123 13 130 305 13 1 13 0 -1.1 0 -1.1 -1.1 11/17/2004 20:20:00 12.1 2.1 17.2 5.7 11.7 2.1 17.6 5.3 0.4 0 0.4 0.4 122 14 118 305 16 0 16 0 -1 0 -0.8 -1.1 11/17/2004 20:30:00 11.6 1.7 16.4 7.2 11.3 1.7 15.6 6.1 0.4 0 0.4 0.4 123 14 112 305 16 0 16 0 -1 0 -0.8 -1.1 11/17/2004 20:40:00 11.9 1.9 17.9 6.5 11.5 2 17.9 4.9 0.4 0 0.4 0.4 124 15 145 305 16 0 16 0 -1 0 -0.8 -1.1 11/17/2004 20:50:00 13.4 2.3 20.6 6.8 13.1 2.3 19.9 7.6 0.4 0 0.4 0.4 131 13 140 305 15 1 16 0 -1 0 -0.6 -1.1 11/17/2004 21:00:00 13 2.1 18.7 7.6 12.7 2.2 18.3 7.6 0.4 0 0.4 0.4 134 11 142 305 14 0 14 0 -1 0 -0.8 -1.1 11/17/2004 21:10:00 10 2.4 16.4 5.3 9.9 2.4 16.4 5.7 0.4 0 0.4 0.4 123 17 123 305 14 0 14 0 -1.1 0 -0.8 -1.1 11/17/2004 21:20:00 9.2 1.8 15.3 5.3 8.9 1.8 14.1 4.6 0.4 0 0.4 0.4 121 16 111 305 14 0 14 0 -1.1 0 -1.1 -1.1 11/17/2004 21:30:00 10.9 1.9 16.4 6.5 10.5 1.9 14.9 6.1 0.4 0 0.4 0.4 121 12 111 305 16 2 15 0 -1.1 0 -0.6 -1.1 11/17/2004 21:40:00 13.2 2 18.7 8.4 12.6 1.9 17.6 8 0.4 0 0.4 0.4 119 10 127 305 21 0 21 0 -1.1 0 -0.8 -1.1 11/17/2004 21:50:00 12.2 1.9 17.2 6.8 11.8 1.8 19.1 6.5 0.4 0 0.4 0.4 121 10 117 305 22 0 22 0 -1.1 0 -1.1 -1.1 11/17/2004 22:00:00 9.5 1.8 16.8 4.6 9.2 1.8 16.8 4.9 0.4 0 0.4 0.4 118 17 125 305 23 0 22 0 -1.1 0 -1.1 -1.1 11/17/2004 22:10:00 9 2.1 14.9 4.2 8.6 1.9 13.3 4.6 0.4 0 0.4 0.4 115 20 136 305 24 0 24 0 -1.1 0 -0.8 -1.1 11/17/2004 22:20:00 10.2 1.8 14.9 4.9 9.9 1.9 14.5 4.6 0.4 0 0.4 0.4 118 14 114 305 24 0 25 0 -1 0 -0.8 -1.1 11/17/2004 22:30:00 10.2 1.7 15.3 4.6 9.9 1.7 14.9 5.7 0.4 0 0.4 0.4 121 13 124 305 25 0 25 0 -1 0 -0.8 -1.1 11/17/2004 22:40:00 10.8 1.9 15.6 7.2 10.5 1.8 16.1 6.8 0.4 0 0.4 0.4 113 12 130 305 25 0 25 0 -1 0 -0.8 -1.1 11/17/2004 22:50:00 11 2.2 16.4 5.7 10.7 2.2 16.4 4.9 0.4 0 0.4 0.4 115 15 107 305 28 1 30 0 -1 0 -0.8 -1.1 11/17/2004 23:00:00 7.5 2 12.6 3.8 7.3 2 12.2 3 0.4 0 0.4 0.4 107 22 90 305 28 0 28 0 -1 0 -0.8 -1.1 11/17/2004 23:10:00 8.8 1.5 12.6 5.3 8.6 1.7 12.2 4.6 0.4 0 0.4 0.4 112 13 105 305 27 0 27 0 -1 0 -0.4 -1.1 11/17/2004 23:20:00 8.3 1.8 14.1 3.4 8.2 1.7 13.3 4.6 0.4 0 0.4 0.4 116 17 102 305 28 0 28 0 -0.9 0 -0.6 -1.1 11/17/2004 23:30:00 8.6 1.7 13.3 4.2 8.4 1.7 13.3 4.2 0.4 0 0.4 0.4 122 19 118 305 28 0 28 0 -0.8 0 -0.4 -1.1 11/17/2004 23:40:00 8.9 1.4 13 6.1 8.5 1.4 12.6 5.3 0.4 0 0.4 0.4 115 13 104 305 28 0 28 0 -0.8 0 -0.6 -1.1 11/17/2004 23:50:00 8.9 2.3 14.9 4.6 8.6 2.3 13.7 4.2 0.4 0 0.4 0.4 112 19 116 305 29 0 29 0 -0.8 0 -0.4 -0.8 11/18/2004 00:00:00 9.2 2.4 14.1 4.6 9 2.3 13.7 4.9 0.4 0 0.4 0.4 115 14 113 305 30 0 31 0 -0.7 0 -0.4 -0.8 11/18/2004 00:10:00 9.3 1.9 13.7 4.2 8.8 1.8 13.7 4.6 0.4 0 0.4 0.4 105 19 100 305 31 0 31 0 -0.7 0 -0.4 -0.8 11/18/2004 00:20:00 8 1.8 13.3 3.4 7.8 1.7 12.2 2.6 0.4 0 0.4 0.4 97 24 80 305 32 0 32 0 -0.8 0 -0.6 -1.1 11/18/2004 00:30:00 8.4 1.7 13 3.4 8.2 1.7 11.8 3.4 0.4 0 0.4 0.4 101 19 103 305 32 0 32 0 -0.8 0 -0.6 -1.1 11/18/2004 00:40:00 8.1 1.7 12.6 4.2 7.8 1.5 11.5 4.2 0.4 0 0.4 0.4 106 17 108 305 32 0 32 0 -0.9 0 -0.4 -1.1 11/18/2004 00:50:00 7.3 1.5 11.8 4.2 6.9 1.4 11.5 3.4 0.4 0 0.4 0.4 100 17 107 305 31 0 31 0 -0.9 0 -0.6 -1.1 11/18/2004 01:00:00 9.3 1.6 13.3 5.3 9.1 1.5 13.7 5.7 0.4 0 0.4 0.4 110 12 110 305 32 0 32 0 -1 0 -0.6 -1.1 11/18/2004 01:10:00 8.9 2.3 15.6 4.2 8.8 2.3 13.7 3 0.4 0 0.4 0.4 84 17 81 305 22 10 11 0 -0.8 0 -0.6 -1.1 11/18/2004 01:20:00 9.9 2.1 15.6 4.9 9.7 2 14.9 4.9 0.4 0 0.4 0.4 86 16 94 305 10 0 10 0 -0.8 0 -0.6 -1.1 11/18/2004 01:30:00 10.6 2.1 16.4 4.9 10.5 2 15.6 6.1 0.4 0 0.4 0.4 81 15 94 305 10 0 10 0 -0.8 0 -0.4 -1.1 11/18/2004 01:40:00 9.3 2 14.1 4.2 9 2 13.7 4.2 0.4 0 0.4 0.4 90 18 85 305 10 0 10 0 -0.8 0 -0.4 -1.1 11/18/2004 01:50:00 10.7 1.8 15.3 6.5 10.5 1.8 15.3 5.7 0.4 0 0.4 0.4 82 11 80 305 10 0 10 0 -0.9 0 -0.4 -1.1 11/18/2004 02:00:00 11.3 2 16.1 6.5 11 2.2 16.1 5.7 0.4 0 0.4 0.4 84 12 73 305 10 0 9 0 -0.9 0.1 -0.4 -1.1 11/18/2004 02:10:00 11.1 1.7 15.6 6.5 10.9 1.7 16.1 6.8 0.4 0 0.4 0.4 83 13 58 305 9 0 9 0 -1 0.1 -0.4 -1.1 11/18/2004 02:20:00 11.7 1.8 18.7 6.1 11.5 1.9 17.6 6.1 0.4 0 0.4 0.4 83 10 73 305 9 0 9 0 -0.9 0.1 -0.4 -1.1 11/18/2004 02:30:00 11.9 1.5 15.6 8 11.6 1.5 15.3 8 0.4 0 0.4 0.4 86 9 84 305 9 0 9 0 -1 0.1 -0.4 -1.1 11/18/2004 02:40:00 12 1.4 15.6 7.6 11.6 1.5 15.3 6.8 0.4 0 0.4 0.4 84 8 78 305 9 0 9 0 -0.9 0.1 -0.4 -1.1 11/18/2004 02:50:00 11.8 1.4 14.9 7.6 11.6 1.4 14.9 7.6 0.4 0 0.4 0.4 82 9 89 305 9 0 9 0 -1 0 -0.6 -1.1 11/18/2004 03:00:00 11.9 1.3 15.3 7.6 11.6 1.3 14.5 8 0.4 0 0.4 0.4 81 7 80 305 9 0 9 0 -1.1 0 -0.4 -1.1 11/18/2004 03:10:00 11.3 1 14.5 7.2 11 1.1 14.9 7.2 0.4 0 0.4 0.4 85 7 90 305 9 0 9 0 -1.1 0 -0.6 -1.3 11/18/2004 03:20:00 10.1 1.5 13.3 6.1 9.8 1.3 13 6.1 0.4 0 0.4 0.4 83 9 66 305 9 0 9 0 -1.1 0 -0.6 -1.3 11/18/2004 03:30:00 11.2 1.1 14.1 7.2 11 1.2 14.1 6.5 0.4 0 0.4 0.4 79 7 76 305 9 0 9 0 -1.1 0 -0.8 -1.1 11/18/2004 03:40:00 10.9 1.1 14.9 6.8 10.6 1.1 13.3 6.8 0.4 0 0.4 0.4 83 8 102 305 9 0 9 0 -1.1 0 -0.8 -1.3 11/18/2004 03:50:00 10.5 1.2 13.3 7.2 10.2 1.2 13 6.8 0.4 0 0.4 0.4 81 8 89 305 9 0 9 0 -1.1 0 -0.6 -1.3 11/18/2004 04:00:00 9.9 1.3 13 4.9 9.6 1.4 13.7 5.7 0.4 0 0.4 0.4 81 8 80 305 9 0 9 0 -1 0 -0.6 -1.1 11/18/2004 04:10:00 10.1 1.2 13 6.5 9.9 1.1 12.2 6.1 0.4 0 0.4 0.4 83 8 75 305 9 0 9 0 -1 0.1 -0.6 -1.1 11/18/2004 04:20:00 10.9 1 13.3 7.2 10.6 1 13.3 8 0.4 0 0.4 0.4 80 6 84 305 9 0 9 0 -1 0 -0.6 -1.1 11/18/2004 04:30:00 10.4 1 12.6 7.6 10.1 1 12.2 6.8 0.4 0 0.4 0.4 83 8 78 305 9 0 9 0 -1 0 -0.6 -1.1 11/18/2004 04:40:00 10 1 12.2 6.8 9.6 1.2 13 6.1 0.4 0 0.4 0.4 80 7 68 305 9 0 9 0 -1.1 0 -0.6 -1.1 11/18/2004 04:50:00 10.5 1 13.3 6.5 10.2 1.1 13 6.1 0.4 0 0.4 0.4 80 5 77 305 9 0 9 0 -1.1 0 -0.6 -1.1 11/18/2004 05:00:00 10.6 0.8 13 7.6 10.3 0.8 12.6 7.6 0.4 0 0.4 0.4 81 6 77 305 9 0 9 0 -1.2 0 -1.1 -1.3 11/18/2004 05:10:00 10.4 0.9 12.6 7.6 10.1 1 13 6.8 0.4 0 0.4 0.4 79 6 78 305 9 0 9 0 -1.2 0 -1.1 -1.3 11/18/2004 05:20:00 9.6 1 12.2 6.5 9.4 1 11.8 5.7 0.4 0 0.4 0.4 79 6 80 305 9 0 9 0 -1.1 0 -0.8 -1.3 11/18/2004 05:30:00 9.2 0.8 11.8 6.8 8.9 0.9 11.8 6.1 0.4 0 0.4 0.4 78 7 84 305 9 0 9 0 -1.2 0 -1.1 -1.3 11/18/2004 05:40:00 9.9 0.8 12.6 8 9.7 0.8 11.8 7.2 0.4 0 0.4 0.4 76 6 71 305 9 0 9 0 -1.2 0 -1.1 -1.3 11/18/2004 05:50:00 10.1 1 13 7.2 9.7 1 13.3 7.2 0.4 0 0.4 0.4 81 7 82 305 10 0 9 0 -1.2 0 -1.1 -1.3 11/18/2004 06:00:00 10.4 0.7 12.6 8 10.2 0.8 12.6 8 0.4 0 0.4 0.4 77 5 80 305 10 0 9 0 -1.2 0 -0.6 -1.3 11/18/2004 06:10:00 10 0.7 11.5 8 9.8 0.8 12.2 8 0.4 0 0.4 0.4 75 5 70 305 10 0 9 0 -1.3 0 -0.6 -1.5 11/18/2004 06:20:00 9.4 0.8 11.5 6.8 9.1 0.9 11.1 6.5 0.4 0 0.4 0.4 77 4 79 305 10 0 9 0 -1.4 0 -0.8 -1.3 11/18/2004 06:30:00 10 0.8 11.8 7.6 9.8 1 12.6 6.5 0.4 0 0.4 0.4 75 5 77 305 10 0 10 0 -1.3 0 -1.1 -1.3 11/18/2004 06:40:00 11.3 0.6 13 9.5 11.2 0.7 13 9.5 0.4 0 0.4 0.4 71 4 67 305 10 0 10 0 -1.2 0 -0.6 -1.3 11/18/2004 06:50:00 11.5 0.8 13.3 9.1 11.4 0.9 13 9.5 0.4 0 0.4 0.4 72 5 69 305 10 0 10 0 -1.3 0 -1.1 -1.3 11/18/2004 07:00:00 11.8 1 15.3 8.8 11.4 1.2 14.1 7.6 0.4 0 0.4 0.4 78 6 96 305 10 0 10 0 -1.5 0.1 -0.8 -1.8 11/18/2004 07:10:00 11.2 0.9 13 8.8 11 1 13 7.6 0.4 0 0.4 0.4 72 5 73 305 10 0 10 0 -1.5 0 -1.1 -1.8 11/18/2004 07:20:00 11.8 0.7 14.1 9.5 11.6 0.8 13.7 9.5 0.4 0 0.4 0.4 70 3 70 305 10 0 10 0 -1.4 0 -0.8 -1.5 11/18/2004 07:30:00 11.6 0.6 13 10.3 11.5 0.6 13.3 9.9 0.4 0 0.4 0.4 66 3 65 305 10 0 10 0 -1.3 0 -1.1 -1.3 11/18/2004 07:40:00 11.4 0.7 13.3 9.1 11.3 0.8 13.3 8.8 0.4 0 0.4 0.4 66 4 63 305 10 0 10 0 -1.3 0 -0.8 -1.3 11/18/2004 07:50:00 11.1 0.8 13.3 9.1 10.9 0.8 13 8.8 0.4 0 0.4 0.4 65 3 67 305 10 0 10 0 -1.3 0 -1.1 -1.3 11/18/2004 08:00:00 11.4 1 13.3 8.4 11.1 1.1 13 8 0.4 0 0.4 0.4 68 4 71 305 10 0 10 0 -1.2 0 -0.6 -1.3 11/18/2004 08:10:00 11.4 0.8 13.7 9.5 11.2 0.8 13.7 8.8 0.4 0 0.4 0.4 74 5 70 305 10 0 10 0 -1.6 0.1 -1.1 -1.8 11/18/2004 08:20:00 11.4 0.8 13 8.4 11.1 0.9 13 8 0.4 0 0.4 0.4 75 5 70 305 10 0 10 0 -1.5 0 -1.1 -1.8 11/18/2004 08:30:00 11.3 0.7 13.3 9.1 11.1 0.7 13 8.8 0.4 0 0.4 0.4 72 4 71 305 10 0 10 0 -1.5 0 -1.3 -1.8 11/18/2004 08:40:00 11 0.7 13 8.8 10.8 0.8 13 8.8 0.4 0 0.4 0.4 70 4 67 305 10 0 10 0 -1.4 0 -1.1 -1.5 11/18/2004 08:50:00 11 0.8 14.1 8.8 10.8 0.8 13 8.8 0.4 0 0.4 0.4 71 4 75 305 10 0 10 0 -1.4 0 -1.1 -1.5 11/18/2004 09:00:00 11 0.6 12.2 9.1 10.8 0.8 12.6 8.4 0.4 0 0.4 0.4 70 3 67 305 10 0 10 0 -1.5 0 -1.1 -1.8 11/18/2004 09:10:00 10.6 0.6 12.6 8.8 10.5 0.7 12.2 8.4 0.4 0 0.4 0.4 70 4 65 305 10 0 9 0 -1.5 0 -1.3 -1.8 11/18/2004 09:20:00 9.9 0.8 11.8 8 9.7 0.8 12.2 7.6 0.4 0 0.4 0.4 71 4 73 305 10 0 9 0 -1.4 0 -1.1 -1.8 11/18/2004 09:30:00 10.7 1 13.3 8.4 10.6 1 13.3 8 0.4 0 0.4 0.4 72 7 71 305 10 0 10 0 -1.4 0 -1.1 -1.8 11/18/2004 09:40:00 10.3 0.8 12.6 8.4 10.1 0.9 12.6 7.6 0.4 0 0.4 0.4 76 5 81 305 10 0 10 0 -1.5 0 -1.3 -1.8 11/18/2004 09:50:00 10 0.6 11.5 8.4 9.7 0.7 11.5 8 0.4 0 0.4 0.4 72 4 76 305 12 0 12 0 -1.4 0 -1.1 -1.5 11/18/2004 10:00:00 10.7 0.9 13 8.4 10.5 0.9 13 8 0.4 0 0.4 0.4 70 4 74 305 11 0 11 0 -1.3 0 -1.1 -1.3 11/18/2004 10:10:00 10.7 0.6 12.2 9.1 10.6 0.7 12.2 8.8 0.4 0 0.4 0.4 68 3 72 305 11 0 11 0 -1.4 0 -1.1 -1.5 11/18/2004 10:20:00 12.1 0.6 13.7 9.9 11.9 0.6 13.3 9.5 0.4 0 0.4 0.4 71 4 74 305 11 0 11 0 -1.4 0 -1.1 -1.5 11/18/2004 10:30:00 10.4 1.3 13.3 7.6 10.1 1.2 13 7.6 0.4 0 0.4 0.4 76 5 80 305 11 0 11 0 -1.4 0 -1.1 -1.5 11/18/2004 10:40:00 9.3 1.1 12.2 7.2 9.1 1.1 12.2 6.8 0.4 0 0.4 0.4 72 6 67 305 10 0 10 0 -1.1 0 -0.6 -1.3 11/18/2004 10:50:00 11.7 0.8 13.7 9.9 11.6 0.8 13.3 9.9 0.4 0 0.4 0.4 69 4 77 305 10 0 11 0 -1.1 0 -0.6 -1.3 11/18/2004 11:00:00 10.8 0.6 13 9.1 10.6 0.7 13 8.8 0.4 0 0.4 0.4 68 3 67 305 10 0 10 0 -1.1 0 -0.6 -1.3 11/18/2004 11:10:00 10.5 0.6 12.6 8.8 10.4 0.6 11.8 8.4 0.4 0 0.4 0.4 68 3 76 305 10 0 10 0 -1.1 0 -1.1 -1.3 11/18/2004 11:20:00 10.5 0.7 12.2 8.4 10.2 0.7 11.8 8 0.4 0 0.4 0.4 73 5 71 305 10 0 10 0 -1.1 0 -1.1 -1.3 11/18/2004 11:30:00 10.1 0.9 12.6 8 9.9 1 11.8 7.2 0.4 0 0.4 0.4 76 5 69 305 10 0 10 0 -1.1 0 -1.1 -1.3 11/18/2004 11:40:00 9.9 0.7 11.8 8 9.6 0.8 11.5 7.6 0.4 0 0.4 0.4 72 5 68 305 10 0 10 0 -1.1 0 -1.1 -1.3 11/18/2004 11:50:00 10.7 0.6 11.8 9.5 10.5 0.7 11.8 8.4 0.4 0 0.4 0.4 67 2 66 305 10 0 9 0 -1.1 0 -0.6 -1.1 11/18/2004 12:00:00 11.1 0.5 12.2 9.9 11 0.6 12.2 9.1 0.4 0 0.4 0.4 66 2 65 305 10 0 9 0 -1.1 0 -0.6 -1.3 11/18/2004 12:10:00 10.2 0.6 11.5 8 10.1 0.6 11.5 8.4 0.4 0 0.4 0.4 65 3 71 305 10 0 10 0 -1.1 0 -0.6 -1.1 11/18/2004 12:20:00 9.9 0.5 11.1 8.8 9.8 0.5 11.1 8.4 0.4 0 0.4 0.4 65 3 62 305 10 0 9 0 -1 0 -0.6 -1.1 11/18/2004 12:30:00 9.5 0.8 11.1 7.2 9.4 0.8 11.1 7.2 0.4 0 0.4 0.4 67 4 62 305 10 0 10 0 -1 0 -0.8 -1.1 11/18/2004 12:40:00 8.9 0.7 10.3 7.2 8.7 0.7 10.3 7.2 0.4 0 0.4 0.4 67 4 62 305 10 0 10 0 -1 0 -0.8 -1.1 11/18/2004 12:50:00 9.7 0.6 11.5 8.4 9.5 0.6 11.5 8 0.4 0 0.4 0.4 69 3 71 305 10 0 10 0 -1.1 0 -0.6 -1.1 11/18/2004 13:00:00 9.4 0.6 10.7 7.6 9.2 0.7 10.7 7.2 0.4 0 0.4 0.4 68 4 66 305 10 0 10 0 -1.1 0 -0.8 -1.1 11/18/2004 13:10:00 9.9 0.7 11.5 8 9.8 0.8 11.5 7.2 0.4 0 0.4 0.4 68 4 71 305 10 0 10 0 -0.9 0 -0.6 -1.1 11/18/2004 13:20:00 9.4 0.6 11.1 7.6 9.3 0.7 10.7 7.2 0.4 0 0.4 0.4 71 4 71 305 10 0 9 0 -0.7 0 -0.6 -0.8 11/18/2004 13:30:00 9.1 0.9 11.5 6.8 8.8 1 11.5 6.5 0.4 0 0.4 0.4 72 5 70 305 10 0 10 0 -0.7 0 -0.1 -0.8 11/18/2004 13:40:00 9.1 1 10.7 6.8 8.8 1.1 10.7 6.1 0.4 0 0.4 0.4 70 5 65 305 10 0 10 0 -0.7 0 -0.4 -1.1 11/18/2004 13:50:00 9.2 0.5 10.3 8 9 0.6 10.3 7.2 0.4 0 0.4 0.4 68 3 67 305 10 0 9 0 -0.8 0 -0.6 -1.1 11/18/2004 14:00:00 8.4 0.7 10.3 6.5 8.2 0.8 9.9 6.1 0.4 0 0.4 0.4 71 4 76 305 9 0 9 0 -0.8 0 -0.6 -1.1 11/18/2004 14:10:00 7.7 0.4 8.8 6.5 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 69 3 62 305 9 0 9 0 -0.8 0 -0.4 -0.8 11/18/2004 14:20:00 7.7 0.5 9.1 6.5 7.4 0.5 9.1 6.1 0.4 0 0.4 0.4 70 4 66 305 9 0 9 0 -0.7 0 -0.6 -0.8 11/18/2004 14:30:00 7.3 0.6 8.8 5.7 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 71 4 70 305 9 0 9 0 -0.7 0 -0.6 -0.8 11/18/2004 14:40:00 7.3 0.6 8.8 5.7 7.2 0.7 9.1 5.3 0.4 0 0.4 0.4 70 4 70 305 9 0 9 0 -0.6 0 -0.4 -0.8 11/18/2004 14:50:00 7.4 0.6 9.1 5.3 7.2 0.7 9.1 5.3 0.4 0 0.4 0.4 70 4 66 305 9 0 9 0 -0.6 0 0.1 -0.8 11/18/2004 15:00:00 7.1 0.6 9.1 5.3 6.9 0.7 8.4 5.3 0.4 0 0.4 0.4 71 5 70 305 9 0 9 0 -0.5 0 0.1 -0.6 11/18/2004 15:10:00 7.1 0.7 9.5 5.7 6.9 0.7 9.1 5.3 0.4 0 0.4 0.4 73 5 82 305 9 0 9 0 -0.5 0 -0.4 -0.6 11/18/2004 15:20:00 6.9 0.6 8.8 5.3 6.7 0.7 9.1 4.6 0.4 0 0.4 0.4 80 6 84 305 9 0 9 0 -0.5 0 0.1 -0.6 11/18/2004 15:30:00 5.9 0.8 8 3 5.6 0.8 7.6 3 0.4 0 0.4 0.4 82 10 90 305 9 0 9 0 -0.5 0 -0.4 -0.6 11/18/2004 15:40:00 5.6 0.9 7.6 3 5.4 1 7.2 2.6 0.4 0 0.4 0.4 87 10 89 305 9 0 9 0 -0.7 0 -0.6 -0.8 11/18/2004 15:50:00 3.9 1.1 6.8 1.1 3.7 1.1 6.8 1.5 0.4 0 0.4 0.4 82 17 76 305 9 0 9 0 -0.7 0 -0.6 -0.8 11/18/2004 16:00:00 3 1.3 6.5 0.4 2.9 1.2 6.5 1.1 0.4 0 0.4 0.4 89 20 77 305 9 0 9 0 -0.7 0 -0.4 -0.8 11/18/2004 16:10:00 1.6 0.9 3.8 0.4 1.7 0.8 3.8 0.4 0.4 0 0.4 0.4 108 18 112 305 9 0 9 0 -0.8 0 -0.6 -1.1 11/18/2004 16:20:00 2.2 1 4.6 0.4 2.3 0.8 4.2 0.4 0.4 0 0.4 0.4 100 20 87 305 9 0 9 0 -0.8 0 -0.6 -1.1 11/18/2004 16:30:00 3.1 0.8 5.3 0.4 2.8 0.6 4.6 1.1 0.4 0 0.4 0.4 100 15 96 305 9 0 9 0 -0.9 0 -0.6 -1.1 11/18/2004 16:40:00 3 0.8 4.6 0.7 2.7 0.7 4.6 1.1 0.4 0 0.4 0.4 94 13 100 305 9 0 9 0 -1 0 -0.8 -1.1 11/18/2004 16:50:00 2.6 0.6 4.2 1.1 2.5 0.5 4.2 1.5 0.4 0 0.4 0.4 101 12 108 305 9 0 9 0 -1 0 -0.8 -1.1 11/18/2004 17:00:00 2.3 1 4.6 0.4 2.1 0.9 4.6 0.4 0.4 0 0.4 0.4 102 15 103 305 9 0 9 0 -1.1 0 -0.6 -1.3 11/18/2004 17:10:00 1.5 0.8 3.4 0.4 1.7 0.6 3.8 0.4 0.4 0 0.4 0.4 90 17 122 305 9 0 9 0 -1.1 0 -1.1 -1.3 11/18/2004 17:20:00 2.5 0.8 4.6 0.4 2.4 0.7 4.2 0.7 0.4 0 0.4 0.4 102 14 80 305 9 0 9 0 -1.1 0 -0.8 -1.3 11/18/2004 17:30:00 2.4 0.8 4.2 0.4 2.3 0.8 3.8 0.4 0.4 0 0.4 0.4 102 12 92 305 9 0 9 0 -1.1 0 -1.1 -1.3 11/18/2004 17:40:00 2.7 0.7 4.6 0.7 2.6 0.6 3.8 1.1 0.4 0 0.4 0.4 97 12 90 305 10 0 10 0 -1.1 0 -1.1 -1.3 11/18/2004 17:50:00 3.2 0.7 4.6 1.5 3 0.6 4.2 1.1 0.4 0 0.4 0.4 113 10 112 305 9 0 9 0 -1.2 0 -1.1 -1.3 11/18/2004 18:00:00 3.8 0.8 6.5 1.9 3.7 0.7 5.7 1.9 0.4 0 0.4 0.4 122 10 108 305 9 0 9 0 -1.4 0 -1.3 -1.5 11/18/2004 18:10:00 4.5 0.7 6.1 2.6 4.2 0.7 6.1 2.3 0.4 0 0.4 0.4 122 12 118 305 10 0 9 0 -1.2 0 -1.1 -1.3 11/18/2004 18:20:00 5 1.1 7.2 1.9 4.9 1 6.8 2.3 0.4 0 0.4 0.4 137 11 140 305 9 0 9 0 -1.1 0 -0.6 -1.1 11/18/2004 18:30:00 5 0.8 6.5 2.6 4.9 0.7 6.5 1.9 0.4 0 0.4 0.4 138 7 145 305 9 0 9 0 -1.2 0 -0.6 -1.3 11/18/2004 18:40:00 4.8 0.5 6.1 3.8 4.7 0.5 6.1 3.4 0.4 0 0.4 0.4 138 6 144 305 9 0 9 0 -1.3 0 -1.1 -1.5 11/18/2004 18:50:00 4.9 0.5 6.1 3.4 4.7 0.5 6.1 3.4 0.4 0 0.4 0.4 135 6 142 305 9 0 9 0 -1.4 0 -1.1 -1.5 11/18/2004 19:00:00 4.3 0.7 5.7 2.6 4.2 0.6 5.7 2.6 0.4 0 0.4 0.4 140 7 141 305 9 0 9 0 -1.5 0 -1.3 -1.5 11/18/2004 19:10:00 3.2 0.6 4.9 1.5 3.3 0.5 4.9 1.5 0.4 0 0.4 0.4 144 11 145 305 9 0 9 0 -1.5 0 -1.3 -1.5 11/18/2004 19:20:00 1.4 1 3.8 0.4 1.8 0.9 3.8 0.4 0.4 0 0.4 0.4 144 15 134 305 9 0 9 0 -1.6 0 -1.3 -1.8 11/18/2004 19:30:00 1.9 0.9 3.8 0.4 2.1 0.7 3.8 0.4 0.4 0 0.4 0.4 142 15 135 305 9 0 9 0 -1.8 0 -1.5 -2 11/18/2004 19:40:00 3.7 0.6 5.3 2.3 3.5 0.5 5.3 2.3 0.4 0 0.4 0.4 138 7 138 305 9 0 10 0 -2 0 -1.8 -2.2 11/18/2004 19:50:00 4.5 0.4 5.7 3 4.3 0.4 5.3 3.4 0.4 0 0.4 0.4 140 5 141 305 10 0 9 0 -2.2 0 -2 -2.4 11/18/2004 20:00:00 4.5 0.4 5.7 3.4 4.3 0.4 5.3 3 0.4 0 0.4 0.4 130 8 131 305 10 0 10 0 -2.5 0 -2 -2.7 11/18/2004 20:10:00 5.2 0.9 7.2 3 5.1 0.8 6.8 3 0.4 0 0.4 0.4 127 9 128 305 10 0 10 0 -2 0.1 -1.5 -2.2 11/18/2004 20:20:00 6.6 0.5 8.8 5.3 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 131 4 129 305 10 0 10 0 -1.6 0 -1.3 -1.8 11/18/2004 20:30:00 6.5 0.5 7.6 4.9 6.3 0.5 8 4.9 0.4 0 0.4 0.4 134 5 140 305 10 0 10 0 -1.5 0.1 -1.1 -1.8 11/18/2004 20:40:00 6.6 0.6 8 4.6 6.4 0.6 8 4.6 0.4 0 0.4 0.4 133 5 136 305 10 0 10 0 -1.5 0 -0.8 -1.8 11/18/2004 20:50:00 5.9 0.7 7.2 3.8 5.8 0.6 7.2 3.8 0.4 0 0.4 0.4 130 7 140 305 10 0 10 0 -1.2 0 -0.8 -1.5 11/18/2004 21:00:00 5.9 1 8.4 3.4 5.8 1 8.8 3.4 0.4 0 0.4 0.4 124 10 127 305 10 0 10 0 -1.2 0 -0.8 -1.3 11/18/2004 21:10:00 6.1 0.8 8.4 3.8 6 0.8 8 3.8 0.4 0 0.4 0.4 130 9 140 305 10 0 10 0 -1.2 0 -0.8 -1.3 11/18/2004 21:20:00 4.5 0.9 6.8 1.9 4.5 0.8 6.5 2.3 0.4 0 0.4 0.4 119 10 109 305 10 0 10 0 -1.2 0 -1.1 -1.3 11/18/2004 21:30:00 4.4 0.7 6.1 3 4.2 0.6 5.7 3 0.4 0 0.4 0.4 115 9 105 305 10 0 10 0 -1.5 0.1 -1.1 -1.8 11/18/2004 21:40:00 4.5 0.6 6.1 2.6 4.4 0.6 5.7 2.6 0.4 0 0.4 0.4 120 11 108 305 10 0 10 0 -1.5 0 -1.3 -1.8 11/18/2004 21:50:00 4.1 0.6 5.7 2.6 4 0.5 5.7 2.6 0.4 0 0.4 0.4 125 10 146 305 10 0 10 0 -1.5 0 -1.3 -1.8 11/18/2004 22:00:00 4 0.5 5.3 2.3 3.9 0.5 5.3 2.6 0.4 0 0.4 0.4 116 13 132 305 10 0 10 0 -1.4 0 -1.1 -1.5 11/18/2004 22:10:00 4.5 0.6 6.1 3 4.4 0.6 6.1 2.6 0.4 0 0.4 0.4 112 10 129 305 10 0 10 0 -1.2 0 -1.1 -1.3 11/18/2004 22:20:00 4.2 0.6 5.7 2.6 4.1 0.5 5.3 2.6 0.4 0 0.4 0.4 118 9 109 305 10 0 10 0 -1.3 0 -0.8 -1.5 11/18/2004 22:30:00 4.8 0.6 6.5 3.4 4.7 0.5 6.1 3 0.4 0 0.4 0.4 114 8 120 305 10 0 10 0 -1.2 0 -1.1 -1.3 11/18/2004 22:40:00 5.1 0.7 6.8 3.4 4.9 0.7 6.5 3.4 0.4 0 0.4 0.4 119 8 138 305 10 0 10 0 -1.1 0 -1.1 -1.3 11/18/2004 22:50:00 5.6 0.6 6.8 4.2 5.4 0.6 6.8 4.2 0.4 0 0.4 0.4 134 8 130 305 10 0 10 0 -0.9 0 -0.6 -1.1 11/18/2004 23:00:00 5 0.4 6.1 3.8 4.9 0.4 6.1 3.8 0.4 0 0.4 0.4 140 5 144 305 10 0 10 0 -1 0.1 -0.6 -1.1 11/18/2004 23:10:00 4.3 0.4 5.3 3.4 4.2 0.4 5.7 3.4 0.4 0 0.4 0.4 139 6 135 305 10 0 10 0 -1 0 -0.8 -1.1 11/18/2004 23:20:00 4.2 0.5 5.7 3 4.1 0.5 6.1 3 0.4 0 0.4 0.4 144 9 142 305 10 0 10 0 -1 0 -0.8 -1.1 11/18/2004 23:30:00 4.1 0.7 6.1 3 4 0.7 6.1 2.6 0.4 0 0.4 0.4 140 7 138 305 10 0 10 0 -1.2 0 -1.1 -1.3 11/18/2004 23:40:00 5.5 1 7.2 3.4 5.3 0.9 7.2 3.4 0.4 0 0.4 0.4 129 8 136 305 10 0 9 0 -1.2 0.2 -0.4 -1.5 11/18/2004 23:50:00 5.5 1 8.4 3 5.5 1 8.4 3.4 0.4 0 0.4 0.4 122 9 116 305 10 0 10 0 -0.7 0 -0.1 -1.1 11/19/2004 00:00:00 6.8 0.8 9.1 4.6 6.6 0.8 9.1 4.6 0.4 0 0.4 0.4 121 9 118 305 10 0 10 0 -0.5 0 -0.1 -0.6 11/19/2004 00:10:00 7 0.9 9.5 4.2 7 0.9 9.5 4.9 0.4 0 0.4 0.4 121 9 130 305 10 0 10 0 -0.4 0 0.1 -0.6 11/19/2004 00:20:00 6.4 0.8 8.8 4.9 6.3 0.8 8.4 4.2 0.4 0 0.4 0.4 119 9 112 305 10 0 10 0 -0.3 0 0.3 -0.4 11/19/2004 00:30:00 7 0.6 9.1 5.3 6.8 0.6 9.5 5.3 0.4 0 0.4 0.4 117 6 126 305 10 0 10 0 -0.2 0 0.3 -0.4 11/19/2004 00:40:00 7.2 0.9 9.1 4.6 6.9 0.9 8.8 4.6 0.4 0 0.4 0.4 112 7 112 305 10 0 10 0 0 0 0.6 -0.1 11/19/2004 00:50:00 6.9 0.7 8.8 5.3 6.7 0.6 8.4 4.9 0.4 0 0.4 0.4 108 7 95 305 10 0 10 0 0.1 0.1 0.6 0.1 11/19/2004 01:00:00 7.2 0.6 8.4 4.9 6.7 0.5 8 4.9 0.4 0 0.4 0.4 103 5 105 305 10 0 10 0 0.2 0.1 0.6 0.1 11/19/2004 01:10:00 7.2 0.7 8.8 4.2 6.9 0.6 8.4 4.9 0.4 0 0.4 0.4 103 4 105 305 10 0 10 0 0.1 0.1 0.6 0.1 11/19/2004 01:20:00 6.6 0.6 8.4 4.6 6.3 0.6 8 4.6 0.4 0 0.4 0.4 107 7 120 305 10 0 10 0 0.2 0 0.8 0.1 11/19/2004 01:30:00 6.9 0.8 8.8 4.2 6.6 0.7 8 4.6 0.4 0 0.4 0.4 111 8 127 305 10 0 10 0 0.4 0 1 0.3 11/19/2004 01:40:00 6.6 1 8.8 4.2 6.2 0.9 8.8 4.2 0.4 0 0.4 0.4 108 9 110 305 10 1 11 0 0.6 0.1 1.3 0.3 11/19/2004 01:50:00 7 0.8 9.1 5.3 6.5 0.7 8.8 4.9 0.4 0 0.4 0.4 106 7 113 305 11 0 11 0 0.7 0.1 1.3 0.6 11/19/2004 02:00:00 5.6 1 8 2.6 5.3 1 7.6 2.6 0.4 0 0.4 0.4 103 11 99 305 10 0 10 0 0.6 0.1 1 0.6 11/19/2004 02:10:00 4.8 1 7.2 2.3 4.5 1 7.2 2.3 0.4 0 0.4 0.4 93 12 101 305 11 0 11 0 0.7 0.1 1.3 0.6 11/19/2004 02:20:00 4.8 0.9 7.6 2.6 4.5 1 8 2.3 0.4 0 0.4 0.4 90 13 61 305 11 0 11 0 0.6 0.1 1.3 0.6 11/19/2004 02:30:00 5.3 1 9.1 3 5 1 8.4 3 0.4 0 0.4 0.4 80 15 82 305 18 3 11 0 0.6 0 1 0.6 11/19/2004 02:40:00 4.8 1 7.2 1.9 4.6 1.1 7.2 2.3 0.4 0 0.4 0.4 83 17 63 305 21 0 21 0 0.6 0 1 0.6 11/19/2004 02:50:00 5 1.3 8.4 1.5 4.7 1.2 8 1.9 0.4 0 0.4 0.4 86 18 68 305 23 0 24 0 0.8 0 1.3 0.6 11/19/2004 03:00:00 5.1 0.9 7.2 2.3 4.9 0.9 6.8 2.3 0.4 0 0.4 0.4 68 14 92 305 24 0 24 0 0.9 0 1.3 0.8 11/19/2004 03:10:00 5.1 1.1 8.4 2.3 4.8 1.1 8 3 0.4 0 0.4 0.4 70 11 66 305 25 0 25 0 0.9 0 1 0.8 11/19/2004 03:20:00 6 1 9.1 4.2 5.7 1 8.8 3.4 0.4 0 0.4 0.4 78 11 81 305 26 0 26 0 1 0 1 1 11/19/2004 03:30:00 5.7 0.9 9.1 3.4 5.4 0.9 8.8 3.4 0.4 0 0.4 0.4 75 13 75 305 26 0 27 0 1 0 1.3 1 11/19/2004 03:40:00 6.4 1.1 9.1 3.4 6.2 1.2 9.1 3 0.4 0 0.4 0.4 75 15 76 305 27 0 27 0 1.2 0 2 1 11/19/2004 03:50:00 6.3 0.9 8.4 4.2 6 0.8 8.8 4.2 0.4 0 0.4 0.4 69 11 86 305 28 0 28 0 1 0.1 1.5 0.6 11/19/2004 04:00:00 6.7 1 9.1 4.6 6.3 1 8.4 4.2 0.4 0 0.4 0.4 74 9 77 305 28 0 28 0 0.5 0 1 0.6 11/19/2004 04:10:00 7.4 0.6 9.5 4.9 6.9 0.7 9.1 4.9 0.4 0 0.4 0.4 81 6 81 305 28 0 28 0 0.5 0 1 0.6 11/19/2004 04:20:00 6.3 0.7 8.4 4.9 6.1 0.6 8.8 4.6 0.4 0 0.4 0.4 77 6 96 305 29 0 28 0 0.6 0 1 0.6 11/19/2004 04:30:00 6.2 0.5 7.2 4.6 6 0.6 7.2 4.2 0.4 0 0.4 0.4 66 5 71 305 29 0 29 0 0.5 0 1.3 0.6 11/19/2004 04:40:00 7.2 0.9 10.3 4.2 6.9 0.8 9.1 3.8 0.4 0 0.4 0.4 74 10 79 305 29 0 29 0 0.6 0.1 1.3 0.6 11/19/2004 04:50:00 8.3 0.8 10.3 6.5 7.8 0.8 9.9 5.3 0.4 0 0.4 0.4 86 6 82 305 29 0 29 0 0.6 0 1 0.6 11/19/2004 05:00:00 7.6 1 9.5 3.4 7.3 1 9.5 4.6 0.4 0 0.4 0.4 85 8 78 305 30 0 30 0 0.6 0 1 0.6 11/19/2004 05:10:00 7.2 0.7 9.5 5.3 7 0.8 8.8 4.9 0.4 0 0.4 0.4 78 8 82 305 30 0 30 0 0.4 0 1 0.3 11/19/2004 05:20:00 7.2 1.3 11.5 4.6 7 1.3 10.7 4.6 0.4 0 0.4 0.4 77 12 73 305 30 0 29 0 0.3 0 0.3 0.1 11/19/2004 05:30:00 6 1.7 10.7 1.9 6 1.7 11.1 2.6 0.4 0 0.4 0.4 79 16 42 305 30 0 31 0 0.4 0 0.6 0.3 11/19/2004 05:40:00 6.3 1.7 13.3 2.6 6.1 1.7 13 2.3 0.4 0 0.4 0.4 80 19 73 305 30 0 30 0 0.5 0 0.6 0.3 11/19/2004 05:50:00 6.7 1.3 9.9 3 6.4 1.3 9.9 3.4 0.4 0 0.4 0.4 78 15 70 305 30 0 30 0 0.5 0 0.6 0.6 11/19/2004 06:00:00 7.3 1.2 11.1 3.8 7.1 1.2 10.7 4.2 0.4 0 0.4 0.4 81 10 77 305 30 0 31 0 0.5 0 1 0.6 11/19/2004 06:10:00 8.4 1 11.8 4.9 7.8 1 10.3 4.9 0.4 0 0.4 0.4 88 9 90 305 31 0 31 0 0.5 0 0.8 0.3 11/19/2004 06:20:00 8.6 1 11.5 5.3 8.1 1 10.7 5.7 0.4 0 0.4 0.4 88 9 83 305 31 0 31 0 0.4 0 0.6 0.3 11/19/2004 06:30:00 8.2 1 11.1 5.3 8 0.9 9.9 5.7 0.4 0 0.4 0.4 75 8 92 305 31 0 31 0 0.5 0 0.6 0.3 11/19/2004 06:40:00 7.9 1 10.7 4.9 7.5 1.1 10.3 4.9 0.4 0 0.4 0.4 71 7 74 305 31 0 31 0 0.4 0 0.6 0.3 11/19/2004 06:50:00 9 0.9 11.8 6.8 8.6 0.8 11.1 6.5 0.4 0 0.4 0.4 76 6 80 305 31 0 32 0 0.5 0 0.6 0.3 11/19/2004 07:00:00 8.9 0.8 10.7 6.8 8.6 0.8 11.1 6.5 0.4 0 0.4 0.4 74 6 68 305 31 0 31 0 0.5 0 1 0.6 11/19/2004 07:10:00 8.5 1 11.1 6.5 8.1 1.1 11.5 6.1 0.4 0 0.4 0.4 68 6 77 305 31 0 32 0 0.5 0 0.8 0.3 11/19/2004 07:20:00 7.6 0.5 8.8 6.1 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 61 3 61 305 31 0 31 0 0.4 0 1 0.3 11/19/2004 07:30:00 8.5 0.5 10.3 7.2 8.2 0.5 9.9 7.2 0.4 0 0.4 0.4 61 3 65 305 31 0 31 0 0.5 0 0.6 0.3 11/19/2004 07:40:00 10 0.9 12.2 7.6 9.6 1 11.8 7.2 0.4 0 0.4 0.4 66 5 61 305 31 0 31 0 0.5 0 0.6 0.3 11/19/2004 07:50:00 10.9 0.8 13.3 8.4 10.7 0.8 13.3 8 0.4 0 0.4 0.4 71 5 71 305 32 0 32 0 0.6 0 0.8 0.6 11/19/2004 08:00:00 10.7 1.1 14.5 8 10.3 1.2 13.7 7.2 0.4 0 0.4 0.4 75 8 67 305 32 0 32 0 0.8 0 1.3 0.6 11/19/2004 08:10:00 10.5 1.3 14.5 7.2 10 1.3 14.1 6.5 0.4 0 0.4 0.4 79 8 82 305 32 0 32 0 0.8 0 1.3 0.6 11/19/2004 08:20:00 10.7 1.3 16.1 7.6 10.3 1.2 14.5 7.6 0.4 0 0.4 0.4 77 8 73 305 32 0 32 0 0.9 0 1.3 0.8 11/19/2004 08:30:00 11.4 1.5 16.1 7.2 11 1.5 15.6 6.5 0.4 0 0.4 0.4 76 9 68 305 32 0 32 0 1 0 1.5 0.8 11/19/2004 08:40:00 11.9 1.1 15.6 8.4 11.6 1.2 14.1 8.8 0.4 0 0.4 0.4 75 7 76 305 32 0 32 0 1 0 1.5 1 11/19/2004 08:50:00 12.2 0.9 14.5 9.9 11.9 1 14.9 8.8 0.4 0 0.4 0.4 73 5 78 305 32 0 32 0 1.1 0 1.5 1 11/19/2004 09:00:00 12.6 1 14.5 9.5 12.2 1 14.5 8.4 0.4 0 0.4 0.4 71 5 72 305 31 0 32 0 1.1 0 1.5 1 11/19/2004 09:10:00 12.6 0.7 14.1 10.7 12.3 0.8 14.1 10.3 0.4 0 0.4 0.4 69 4 77 305 31 0 31 0 0.9 0 1.5 0.8 11/19/2004 09:20:00 12 0.9 14.5 9.1 11.7 1 14.1 9.5 0.4 0 0.4 0.4 66 5 62 305 30 0 30 0 0.6 0.1 1.3 0.6 11/19/2004 09:30:00 13 1 15.3 10.3 12.7 1 14.9 9.9 0.4 0 0.4 0.4 63 4 72 305 30 0 29 0 0.5 0 0.6 0.3 11/19/2004 09:40:00 12.9 1 15.6 10.7 12.5 1.1 15.3 10.3 0.4 0 0.4 0.4 59 4 66 305 29 0 29 0 0.4 0 0.6 0.3 11/19/2004 09:50:00 12.7 0.9 15.3 9.9 12.5 1 14.9 9.9 0.4 0 0.4 0.4 59 4 58 305 28 0 27 0 0.4 0 0.6 0.3 11/19/2004 10:00:00 13 1 15.6 10.7 12.7 1.1 15.6 10.3 0.4 0 0.4 0.4 58 4 56 305 27 1 27 0 0.3 0 0.8 0.3 11/19/2004 10:10:00 13.4 1.2 16.1 10.7 13.2 1.3 16.1 10.3 0.4 0 0.4 0.4 52 4 54 305 12 2 12 0 0.4 0 0.8 0.1 11/19/2004 10:20:00 13.2 0.8 15.3 9.9 13 0.9 14.9 10.3 0.4 0 0.4 0.4 47 3 49 305 10 0 11 0 0.3 0 0.8 0.3 11/19/2004 10:30:00 12.8 1 14.9 10.7 12.6 1 14.5 10.3 0.4 0 0.4 0.4 49 3 48 305 10 0 9 0 0.4 0 1 0.3 11/19/2004 10:40:00 13.6 1.4 17.6 10.7 13.4 1.4 17.2 10.7 0.4 0 0.4 0.4 50 5 43 305 9 0 9 0 0.5 0 1 0.3 11/19/2004 10:50:00 13.8 1.3 16.1 10.3 13.5 1.3 16.4 10.3 0.4 0 0.4 0.4 53 5 47 305 9 0 9 0 0.4 0 1 0.3 11/19/2004 11:00:00 13.4 1.6 17.2 10.3 13.1 1.7 16.8 9.5 0.4 0 0.4 0.4 52 5 56 305 9 0 9 0 0.3 0 0.6 0.1 11/19/2004 11:10:00 15.3 1.4 18.3 11.5 14.9 1.4 19.1 11.5 0.4 0 0.4 0.4 57 5 56 305 8 0 8 0 0 0 0.6 -0.1 11/19/2004 11:20:00 15.9 1.3 19.1 13 15.4 1.4 19.1 12.2 0.4 0 0.4 0.4 59 5 57 305 9 0 9 0 -0.1 0 0.1 -0.4 11/19/2004 11:30:00 16.1 1.3 19.1 12.6 15.8 1.3 18.3 12.2 0.4 0 0.4 0.4 57 5 57 305 9 0 9 0 -0.1 0 0.1 -0.1 11/19/2004 11:40:00 12.9 1.5 16.4 8.8 12.6 1.5 16.1 8.4 0.4 0 0.4 0.4 58 6 62 305 9 0 9 0 0 0 0.6 -0.1 11/19/2004 11:50:00 12.7 1.9 19.1 9.5 12.4 2 19.1 8.8 0.4 0 0.4 0.4 50 6 54 305 9 0 9 0 0.2 0 0.6 0.1 11/19/2004 12:00:00 16.8 2 21.8 12.2 16.4 2.1 21.8 11.5 0.4 0 0.4 0.4 53 6 47 305 9 0 9 0 0.2 0 0.3 0.1 11/19/2004 12:10:00 19.2 1.7 23.7 14.9 18.6 1.7 22.9 13.7 0.4 0 0.4 0.4 54 5 54 305 9 0 9 0 0.2 0 0.6 0.1 11/19/2004 12:20:00 20 1.5 23.7 16.4 19.5 1.6 23.7 15.6 0.4 0 0.4 0.4 52 5 50 305 9 0 9 0 0.2 0 0.6 0.1 11/19/2004 12:30:00 18.9 1.6 22.9 14.9 18.5 1.7 22.1 13 0.4 0 0.4 0.4 51 5 57 305 9 0 9 0 0.1 0 0.3 0.1 11/19/2004 12:40:00 17.4 1.5 21 14.1 16.9 1.4 21.8 13.3 0.4 0 0.4 0.4 47 5 50 305 9 0 9 0 0.2 0 0.3 0.1 11/19/2004 12:50:00 17.4 1.7 21.4 13 17 1.8 21.4 12.6 0.4 0 0.4 0.4 49 4 51 305 9 0 9 0 0.3 0 0.6 0.1 11/19/2004 13:00:00 16.7 1.4 20.6 13.7 16.3 1.5 20.2 13 0.4 0 0.4 0.4 51 5 51 305 9 0 9 0 0.3 0 0.8 0.1 11/19/2004 13:10:00 15.9 1.5 21.4 12.6 15.5 1.5 20.2 12.2 0.4 0 0.4 0.4 52 5 50 305 9 0 9 0 0.3 0 0.6 0.3 11/19/2004 13:20:00 15.5 1.6 19.5 11.8 15.1 1.7 19.9 11.5 0.4 0 0.4 0.4 52 5 48 305 9 0 9 0 0.4 0 0.6 0.3 11/19/2004 13:30:00 17.7 1.5 21.4 13.7 17.2 1.5 21 13 0.4 0 0.4 0.4 49 4 51 305 9 0 9 0 0.5 0 0.6 0.3 11/19/2004 13:40:00 17.1 1.5 20.6 13.3 16.7 1.7 21 11.8 0.4 0 0.4 0.4 46 4 44 305 9 0 9 0 0.4 0 0.8 0.3 11/19/2004 13:50:00 16.7 1.2 19.5 13.7 16.4 1.3 19.5 13.3 0.4 0 0.4 0.4 46 5 54 305 9 0 9 0 0.4 0 0.6 0.3 11/19/2004 14:00:00 16.3 1.3 19.5 12.6 15.9 1.3 19.5 12.6 0.4 0 0.4 0.4 46 4 47 305 8 0 8 0 0.4 0 1 0.3 11/19/2004 14:10:00 16.2 1.3 19.1 13 15.9 1.3 19.1 12.2 0.4 0 0.4 0.4 49 4 48 305 8 0 8 0 0.5 0 0.6 0.3 11/19/2004 14:20:00 15.8 1.3 19.1 13 15.4 1.2 18.3 12.6 0.4 0 0.4 0.4 49 5 58 305 8 0 8 0 0.5 0 0.8 0.3 11/19/2004 14:30:00 15.6 1.3 18.7 12.6 15.3 1.5 19.1 11.8 0.4 0 0.4 0.4 47 5 42 305 8 0 8 0 0.5 0 0.6 0.3 11/19/2004 14:40:00 16.1 1.7 20.6 12.2 15.7 1.7 20.2 11.8 0.4 0 0.4 0.4 48 4 46 305 8 0 8 0 0.5 0 1 0.6 11/19/2004 14:50:00 16.1 1.5 19.5 12.6 15.7 1.5 19.1 12.2 0.4 0 0.4 0.4 48 4 48 305 8 0 8 0 0.4 0 0.6 0.3 11/19/2004 15:00:00 16.1 1.3 19.5 12.2 15.9 1.3 19.1 12.2 0.4 0 0.4 0.4 47 5 51 305 8 0 8 0 0.2 0.1 0.6 0.1 11/19/2004 15:10:00 16.4 1.2 19.5 13.3 16.2 1.2 19.5 13.3 0.4 0 0.4 0.4 45 5 48 305 9 0 9 0 -0.1 0 0.6 -0.4 11/19/2004 15:20:00 15.8 1.4 19.1 12.2 15.6 1.4 19.1 12.2 0.4 0 0.4 0.4 45 4 49 305 9 0 9 0 -0.2 0 0.1 -0.4 11/19/2004 15:30:00 15.9 1.2 19.5 11.8 15.6 1.2 19.1 12.2 0.4 0 0.4 0.4 45 4 42 305 9 0 9 0 -0.3 0 -0.1 -0.4 11/19/2004 15:40:00 15.8 1.3 18.7 12.6 15.5 1.4 18.7 12.2 0.4 0 0.4 0.4 44 4 45 305 10 0 9 0 -0.3 0 0.1 -0.4 11/19/2004 15:50:00 14.9 1.4 17.9 11.5 14.6 1.5 17.6 11.1 0.4 0 0.4 0.4 43 5 45 305 10 0 10 0 -0.4 0 -0.4 -0.4 11/19/2004 16:00:00 15.4 1.2 18.7 12.2 15.1 1.2 18.7 11.1 0.4 0 0.4 0.4 43 4 47 305 10 0 10 0 -0.3 0 0.1 -0.4 11/19/2004 16:10:00 15.4 1.3 18.7 11.8 15 1.4 18.3 11.8 0.4 0 0.4 0.4 45 5 48 305 11 0 11 0 -0.3 0 -0.1 -0.4 11/19/2004 16:20:00 15.6 1.4 18.7 12.2 15.2 1.5 19.1 11.1 0.4 0 0.4 0.4 46 4 45 305 11 0 11 0 -0.3 0 -0.1 -0.4 11/19/2004 16:30:00 15.5 1.2 19.5 12.2 15.1 1.2 18.3 11.8 0.4 0 0.4 0.4 45 4 48 305 11 0 11 0 -0.3 0 -0.1 -0.4 11/19/2004 16:40:00 15.2 0.9 17.6 12.6 14.9 1 17.2 12.2 0.4 0 0.4 0.4 47 4 46 305 11 0 11 0 -0.2 0 0.1 -0.4 11/19/2004 16:50:00 14.6 1.2 17.9 11.8 14.3 1.2 17.6 11.5 0.4 0 0.4 0.4 51 4 53 305 11 0 11 0 -0.1 0 0.1 -0.4 11/19/2004 17:00:00 14.7 1.1 17.6 12.6 14.4 1.1 17.6 11.5 0.4 0 0.4 0.4 53 5 48 305 11 0 11 0 -0.1 0 0.1 -0.4 11/19/2004 17:10:00 14.7 1.1 17.6 11.5 14.3 1.2 17.9 11.5 0.4 0 0.4 0.4 51 5 50 305 11 0 11 0 -0.1 0 0.1 -0.4 11/19/2004 17:20:00 15 1.3 18.3 12.2 14.7 1.5 18.3 11.8 0.4 0 0.4 0.4 52 4 46 305 11 0 11 0 -0.2 0 0.1 -0.4 11/19/2004 17:30:00 14.6 1 17.2 12.2 14.3 1.1 17.2 11.8 0.4 0 0.4 0.4 52 4 49 305 12 0 12 0 -0.3 0 -0.1 -0.4 11/19/2004 17:40:00 15.3 1.3 18.3 11.8 15.1 1.4 18.3 11.1 0.4 0 0.4 0.4 49 4 48 305 11 0 12 0 -0.4 0 -0.1 -0.6 11/19/2004 17:50:00 14.8 1.2 17.6 11.8 14.5 1.2 17.6 11.8 0.4 0 0.4 0.4 48 5 50 305 12 0 12 0 -0.5 0 -0.4 -0.6 11/19/2004 18:00:00 14.6 1.3 17.2 11.1 14.3 1.5 17.6 9.9 0.4 0 0.4 0.4 45 4 53 305 12 0 12 0 -0.4 0 0.1 -0.4 11/19/2004 18:10:00 13.8 1 16.8 11.1 13.5 1 16.4 9.9 0.4 0 0.4 0.4 44 4 43 305 12 0 11 0 -0.4 0 -0.1 -0.4 11/19/2004 18:20:00 14.2 1 16.8 10.7 13.9 1.1 16.4 10.7 0.4 0 0.4 0.4 45 3 48 305 12 0 12 0 -0.3 0 -0.1 -0.4 11/19/2004 18:30:00 13.5 0.8 15.3 11.5 13.3 0.9 15.3 10.7 0.4 0 0.4 0.4 49 4 51 305 12 0 11 0 -0.3 0 -0.1 -0.4 11/19/2004 18:40:00 13.6 0.9 15.3 11.5 13.3 1 15.6 10.7 0.4 0 0.4 0.4 50 4 54 305 12 0 12 0 -0.3 0 0.1 -0.4 11/19/2004 18:50:00 12.7 0.8 14.9 10.3 12.4 0.9 15.3 9.5 0.4 0 0.4 0.4 52 4 56 305 12 0 12 0 -0.3 0 -0.1 -0.4 11/19/2004 19:00:00 13.2 1 15.3 10.7 12.8 1 15.3 10.3 0.4 0 0.4 0.4 52 4 52 305 12 0 12 0 -0.2 0 0.3 -0.4 11/19/2004 19:10:00 13 0.9 15.3 10.3 12.8 1 15.6 9.9 0.4 0 0.4 0.4 51 3 48 305 12 0 12 0 -0.1 0 0.3 -0.4 11/19/2004 19:20:00 12.8 1 15.3 10.3 12.4 1.1 14.9 9.5 0.4 0 0.4 0.4 50 4 49 305 12 0 12 0 0 0 0.3 0.1 11/19/2004 19:30:00 13.4 1 15.6 10.7 13 1 15.3 10.3 0.4 0 0.4 0.4 50 4 50 305 12 0 12 0 0.1 0 0.3 0.1 11/19/2004 19:40:00 13.6 1 16.1 11.1 13.3 1.1 16.1 9.5 0.4 0 0.4 0.4 50 4 49 305 12 0 12 0 0.2 0 0.6 0.1 11/19/2004 19:50:00 13.8 1.1 17.2 11.5 13.4 1.1 16.8 10.7 0.4 0 0.4 0.4 50 4 51 305 12 0 12 0 0.2 0 0.3 0.1 11/19/2004 20:00:00 14 1.2 17.2 11.5 13.8 1.3 17.2 11.1 0.4 0 0.4 0.4 50 4 54 305 12 0 12 0 0.2 0.1 0.6 0.1 11/19/2004 20:10:00 14.2 1.2 17.2 11.8 13.8 1.2 16.4 11.5 0.4 0 0.4 0.4 50 4 50 305 12 0 12 0 0.2 0.1 0.6 0.1 11/19/2004 20:20:00 14.4 1 17.2 11.8 14 1.1 16.8 11.1 0.4 0 0.4 0.4 50 5 55 305 12 0 12 0 0.2 0 0.8 0.1 11/19/2004 20:30:00 14.3 1.1 17.9 11.5 14 1.1 17.6 10.7 0.4 0 0.4 0.4 49 4 46 305 12 0 12 0 0.3 0 0.8 0.1 11/19/2004 20:40:00 14.6 1 17.2 12.6 14.2 1 16.8 11.5 0.4 0 0.7 0.4 49 4 48 305 12 0 12 0 0.2 0.1 0.6 0.1 11/19/2004 20:50:00 14.6 1 17.2 12.2 14.3 1.1 16.8 11.5 0.4 0 0.4 0.4 49 4 48 305 12 0 12 0 0.1 0.1 0.6 0.1 11/19/2004 21:00:00 15.1 1.2 18.3 12.2 14.8 1.3 18.3 11.8 0.4 0 0.4 0.4 47 4 51 305 12 0 12 0 0.2 0 0.3 0.1 11/19/2004 21:10:00 15.3 1.2 17.9 12.2 15 1.3 17.9 11.5 0.4 0 0.4 0.4 47 4 48 305 12 0 12 0 0.3 0 0.6 0.1 11/19/2004 21:20:00 15.4 1.2 18.7 11.8 15 1.2 18.3 11.8 0.4 0 0.4 0.4 47 5 53 305 12 0 12 0 0.3 0 0.6 0.1 11/19/2004 21:30:00 15.3 1.2 18.7 12.6 15 1.3 18.3 12.2 0.4 0 0.4 0.4 46 4 41 305 12 0 12 0 0.2 0 0.6 0.1 11/19/2004 21:40:00 14.8 1.1 17.9 11.8 14.6 1.2 17.6 11.5 0.4 0 0.4 0.4 45 4 44 305 12 0 12 0 0.1 0 0.6 0.1 11/19/2004 21:50:00 14.9 1 17.6 12.6 14.6 1.1 17.6 11.8 0.4 0 0.4 0.4 43 4 44 305 12 0 12 0 0 0 0.3 0.1 11/19/2004 22:00:00 15.2 1.1 17.9 11.8 14.9 1.2 17.9 11.8 0.4 0 0.4 0.4 42 4 40 305 12 0 12 0 0 0 0.3 0.1 11/19/2004 22:10:00 14.8 1.1 17.9 11.8 14.5 1.2 17.2 11.5 0.4 0 0.4 0.4 41 4 36 305 12 0 12 0 0 0 0.3 0.1 11/19/2004 22:20:00 14.7 1.1 17.6 12.2 14.6 1.2 17.9 11.5 0.4 0 0.4 0.4 42 4 43 305 12 0 12 0 0 0 0.3 0.1 11/19/2004 22:30:00 15.2 1 17.6 12.2 15 1 17.6 12.2 0.4 0 0.4 0.4 41 4 43 305 12 0 12 0 0.1 0 0.3 0.1 11/19/2004 22:40:00 14.8 1.1 17.9 12.2 14.5 1.2 17.9 11.5 0.4 0 0.4 0.4 41 4 44 305 12 0 12 0 0.2 0 0.6 0.1 11/19/2004 22:50:00 14.6 1 17.2 11.8 14.3 1.1 16.8 11.5 0.4 0 0.4 0.4 40 4 42 305 12 0 12 0 0.2 0 0.6 0.1 11/19/2004 23:00:00 14.1 1.1 16.4 11.5 13.9 1.2 16.8 11.1 0.4 0 0.4 0.4 40 4 37 305 12 0 12 0 0.1 0 0.6 0.1 11/19/2004 23:10:00 14.1 0.9 17.2 12.2 13.7 1 17.2 10.7 0.4 0 0.4 0.4 39 4 40 305 12 0 12 0 0.1 0 0.3 0.1 11/19/2004 23:20:00 14 1 16.4 10.7 13.8 1 16.1 10.7 0.4 0 0.4 0.4 40 4 41 305 12 0 12 0 0.2 0 0.6 0.1 11/19/2004 23:30:00 13.7 1.2 16.4 10.3 13.6 1.2 16.1 10.3 0.4 0 0.4 0.4 39 4 40 305 12 0 12 0 0.3 0 0.3 0.1 11/19/2004 23:40:00 12.7 0.9 14.9 9.9 12.4 1 14.5 9.1 0.4 0 0.4 0.4 40 4 35 305 12 0 12 0 0.2 0 0.6 0.1 11/19/2004 23:50:00 12.4 1 14.9 9.9 12.3 1.1 14.9 9.5 0.4 0 0.4 0.4 40 4 40 305 12 0 12 0 0.3 0 0.3 0.1 11/20/2004 00:00:00 12.6 0.7 14.5 10.3 12.4 0.8 14.5 9.9 0.4 0 0.4 0.4 39 4 43 305 12 0 12 0 0.4 0 0.8 0.3 11/20/2004 00:10:00 12.4 0.8 14.9 10.3 12 0.9 14.9 9.1 0.4 0 0.4 0.4 40 4 39 305 12 0 12 0 0.4 0 1 0.3 11/20/2004 00:20:00 12.6 0.9 14.9 10.3 12.1 1 14.5 9.1 0.4 0 0.4 0.4 40 4 51 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 00:30:00 12.6 0.9 14.5 10.3 12.1 1 14.1 9.5 0.4 0 0.4 0.4 40 4 42 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 00:40:00 12.8 0.7 14.5 10.7 12.4 0.7 14.1 10.3 0.4 0 0.4 0.4 38 3 38 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 00:50:00 12.7 0.7 14.9 10.7 12.4 0.8 14.5 10.3 0.4 0 0.4 0.4 39 4 42 305 12 0 12 0 0.6 0 1 0.6 11/20/2004 01:00:00 12.5 0.8 14.5 10.7 12.2 0.8 14.1 10.3 0.4 0 0.4 0.4 42 4 42 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 01:10:00 12.4 0.7 14.1 10.3 12.2 0.9 14.5 9.5 0.4 0 0.4 0.4 44 4 49 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 01:20:00 11.9 0.8 14.1 9.9 11.5 0.9 14.1 9.5 0.4 0 0.4 0.4 45 4 45 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 01:30:00 11.6 0.7 13.3 9.9 11.4 0.8 13.3 9.1 0.4 0 0.4 0.4 47 4 51 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 01:40:00 11.5 0.7 13.3 9.9 11.2 0.8 13.7 8.8 0.4 0 0.4 0.4 46 4 48 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 01:50:00 11.3 0.7 12.6 9.5 10.9 0.7 13 9.1 0.4 0 0.4 0.4 46 4 46 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 02:00:00 10.7 0.8 12.6 8.8 10.4 0.8 12.6 8.4 0.4 0 0.4 0.4 46 4 45 305 12 0 12 0 0.6 0 1.3 0.6 11/20/2004 02:10:00 10.9 0.6 12.6 9.1 10.6 0.7 12.2 8.4 0.4 0 0.4 0.4 49 4 49 305 12 0 12 0 0.6 0.1 1 0.6 11/20/2004 02:20:00 10.7 0.6 12.6 8.8 10.4 0.6 11.8 8.8 0.4 0 0.4 0.4 45 4 44 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 02:30:00 10.2 0.6 11.8 8.4 10 0.6 11.5 8 0.4 0 0.4 0.4 45 4 50 305 12 0 13 0 0.4 0 0.8 0.1 11/20/2004 02:40:00 10.5 0.6 11.8 8.8 10.2 0.6 11.5 8.4 0.4 0 0.4 0.4 48 4 48 305 12 0 12 0 0.6 0.1 1.3 0.3 11/20/2004 02:50:00 10.7 0.6 12.2 8.8 10.5 0.6 12.2 8.8 0.4 0 0.4 0.4 49 3 48 305 12 0 12 0 0.7 0.1 1.3 0.6 11/20/2004 03:00:00 10.2 0.7 12.2 8.8 9.9 0.7 11.8 8 0.4 0 0.4 0.4 45 4 54 305 12 0 12 0 0.5 0 0.8 0.3 11/20/2004 03:10:00 11 0.6 12.6 9.5 10.7 0.6 12.2 8.8 0.4 0 0.4 0.4 45 3 51 305 12 0 12 0 0.5 0 0.8 0.3 11/20/2004 03:20:00 11.1 0.6 13 9.5 10.8 0.7 12.6 9.1 0.4 0 0.4 0.4 46 3 46 305 12 0 12 0 0.6 0 0.8 0.6 11/20/2004 03:30:00 10.6 0.7 12.6 8.8 10.3 0.8 12.2 8 0.4 0 0.4 0.4 44 4 43 305 12 0 12 0 0.7 0.1 1.3 0.6 11/20/2004 03:40:00 10.2 0.6 11.8 8.8 10 0.6 11.8 8 0.4 0 0.4 0.4 42 4 46 305 12 0 12 0 0.6 0.1 1.3 0.6 11/20/2004 03:50:00 9.5 0.7 11.8 7.6 9.3 0.7 11.5 7.6 0.4 0 0.4 0.4 36 4 41 305 12 0 12 0 0.4 0 1 0.3 11/20/2004 04:00:00 9.4 0.5 11.1 8 9.1 0.6 11.1 7.2 0.4 0 0.4 0.4 36 4 41 305 12 0 12 0 0.5 0 1 0.3 11/20/2004 04:10:00 10 0.6 11.8 8.4 9.7 0.6 11.5 8 0.4 0 0.4 0.4 38 4 39 305 12 0 12 0 0.6 0.1 1.3 0.6 11/20/2004 04:20:00 9.9 0.6 11.8 8.4 9.7 0.6 11.5 8.4 0.4 0 0.4 0.4 36 3 37 305 12 0 12 0 0.6 0.1 1 0.6 11/20/2004 04:30:00 9.5 0.6 11.5 7.6 9.3 0.6 11.1 7.6 0.4 0 0.4 0.4 36 3 39 305 12 0 12 0 0.6 0 1 0.6 11/20/2004 04:40:00 9.4 0.5 11.1 8 9.2 0.5 11.1 7.6 0.4 0 0.4 0.4 35 3 35 305 12 0 12 0 0.6 0 1 0.6 11/20/2004 04:50:00 8.9 0.6 10.3 7.2 8.7 0.6 10.3 6.5 0.4 0 0.4 0.4 33 3 37 305 12 0 12 0 0.6 0 1 0.6 11/20/2004 05:00:00 8.4 0.4 9.5 7.2 8.1 0.5 9.1 6.8 0.4 0 0.4 0.4 31 3 33 305 12 0 11 0 0.5 0 1 0.6 11/20/2004 05:10:00 8 0.5 9.5 6.5 7.8 0.5 9.1 6.8 0.4 0 0.4 0.4 29 3 30 305 12 0 12 0 0.6 0 1 0.6 11/20/2004 05:20:00 7.7 0.5 8.8 6.5 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 28 3 33 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 05:30:00 7.4 0.4 8.4 6.1 7.2 0.5 8.4 6.1 0.4 0 0.4 0.4 22 3 30 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 05:40:00 6.7 0.4 8 5.7 6.6 0.5 7.6 5.3 0.4 0 0.4 0.4 17 3 20 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 05:50:00 6.7 0.4 7.6 5.7 6.6 0.4 7.6 5.7 0.4 0 0.4 0.4 11 3 12 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 06:00:00 6.3 0.4 7.2 5.3 6.3 0.4 7.2 5.3 0.4 0 0.4 0.4 5 3 8 305 12 0 12 0 0.5 0 0.6 0.6 11/20/2004 06:10:00 6 0.4 6.8 4.9 6 0.4 6.8 4.9 0.4 0 0.4 0.4 357 4 1 305 11 0 12 0 0.5 0 0.6 0.6 11/20/2004 06:20:00 5.7 0.4 6.8 4.6 5.7 0.5 7.2 4.9 0.4 0 0.4 0.4 346 4 347 305 12 0 12 0 0.5 0 0.6 0.6 11/20/2004 06:30:00 5 0.4 5.7 4.2 4.9 0.4 5.7 3.8 0.4 0 0.4 0.4 331 5 337 305 12 0 12 0 0.5 0 1 0.6 11/20/2004 06:40:00 5.3 0.3 6.1 4.6 5.1 0.4 6.1 4.2 0.4 0 0.4 0.4 320 5 325 305 12 0 12 0 0.5 0 0.6 0.6 11/20/2004 06:50:00 5.6 0.3 6.5 4.6 5.3 0.4 6.5 4.2 0.4 0 0.4 0.4 312 5 308 305 12 0 13 0 0.5 0 1 0.6 11/20/2004 07:00:00 6 0.4 6.8 4.9 5.6 0.4 6.8 4.6 0.4 0 0.4 0.4 308 4 309 305 12 1 13 0 0.5 0 0.6 0.6 11/20/2004 07:10:00 6.4 0.4 7.2 5.3 5.9 0.5 7.2 4.9 0.4 0 0.4 0.4 307 8 311 305 11 1 13 0 0.5 0 0.6 0.6 11/20/2004 07:20:00 6.7 0.5 8 5.3 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 303 7 300 305 11 1 12 0 0.5 0 0.6 0.3 11/20/2004 07:30:00 7.2 0.5 8.4 5.7 6.7 0.5 8 5.3 0.4 0 0.4 0.4 305 9 306 305 11 1 9 0 0.5 0 1 0.3 11/20/2004 07:40:00 6.7 0.6 8.4 5.3 6.3 0.6 8 4.9 0.4 0 0.4 0.4 301 7 301 305 10 1 9 0 0.5 0 0.6 0.3 11/20/2004 07:50:00 7.1 0.5 8.4 5.7 6.5 0.6 8.4 4.9 0.4 0 0.4 0.4 301 6 303 305 10 1 12 0 0.4 0 0.6 0.3 11/20/2004 08:00:00 7.6 0.6 9.1 5.7 7.1 0.6 8.8 5.3 0.4 0 0.4 0.4 303 6 297 305 10 1 9 0 0.4 0 0.8 0.3 11/20/2004 08:10:00 7.3 0.6 8.8 5.7 6.9 0.6 8.4 4.9 0.4 0 0.4 0.4 299 6 305 305 10 1 12 0 0.3 0 0.8 0.3 11/20/2004 08:20:00 7 0.6 8.4 5.3 6.5 0.7 8.4 4.6 0.4 0 0.4 0.4 295 6 299 305 9 0 9 0 0.3 0 0.8 0.3 11/20/2004 08:30:00 6.9 0.7 8.4 5.3 6.2 0.7 8 4.2 0.4 0 0.4 0.4 291 6 296 305 9 0 9 0 0.3 0 0.6 0.1 11/20/2004 08:40:00 7 0.8 8.8 4.9 6 0.8 8.4 4.2 0.4 0 0.4 0.4 283 5 284 305 9 0 9 0 0.3 0 0.8 0.3 11/20/2004 08:50:00 7.1 0.9 9.1 4.6 5.8 1 7.6 3 0.4 0 0.4 0.4 279 6 283 305 9 0 9 0 0.3 0 0.8 0.1 11/20/2004 09:00:00 7.4 1 9.5 4.9 5.7 1 8 3.4 0.4 0 0.4 0.4 274 7 277 305 9 0 9 0 0.4 0 1 0.3 11/20/2004 09:10:00 8 0.9 9.9 4.6 5.8 0.7 7.6 3.8 0.4 0 0.4 0.4 266 6 267 305 10 0 9 0 0.5 0 1 0.3 11/20/2004 09:20:00 8.1 1 10.3 5.7 6 0.9 8.4 3.4 0.4 0 0.4 0.4 266 7 267 305 10 0 9 0 0.5 0 1 0.3 11/20/2004 09:30:00 8.1 0.7 9.9 5.7 6.4 0.8 8 3.4 0.4 0 0.4 0.4 261 6 261 305 10 0 10 0 0.5 0 1 0.3 11/20/2004 09:40:00 9 1.1 11.5 5.7 7.8 1.4 11.5 4.6 0.4 0 0.4 0.4 253 6 252 305 10 0 9 0 0.5 0 1 0.3 11/20/2004 09:50:00 9.1 1 11.8 6.5 8.1 1.2 10.7 5.3 0.4 0 0.4 0.4 247 7 241 305 10 0 9 0 0.5 0 1 0.3 11/20/2004 10:00:00 10.6 1.1 13 7.6 9.6 1.1 12.6 6.5 0.4 0 0.4 0.4 244 5 247 305 10 0 10 0 0.5 0 1 0.6 11/20/2004 10:10:00 11 0.9 13.7 8.4 9.9 1.1 13 6.5 0.4 0 0.4 0.4 240 6 242 305 10 0 10 0 0.5 0 1 0.6 11/20/2004 10:20:00 10.7 0.8 12.6 8.4 9.6 1 12.2 6.8 0.4 0 0.4 0.4 238 5 244 305 10 0 10 0 0.5 0 1 0.3 11/20/2004 10:30:00 10.8 1 13 8.4 9.9 1.1 12.6 6.8 0.4 0 0.4 0.4 241 6 237 305 10 0 10 0 0.5 0 1 0.3 11/20/2004 10:40:00 10.8 1 13.7 8 9.8 1.1 12.6 6.5 0.4 0 0.4 0.4 244 5 243 305 10 0 9 0 0.4 0 1 0.3 11/20/2004 10:50:00 10.9 0.9 13 8.4 9.9 1.2 13 6.5 0.4 0 0.4 0.4 240 5 243 305 10 0 10 0 0.4 0 0.8 0.3 11/20/2004 11:00:00 12.1 1 14.1 9.1 10.9 1.2 13.3 7.6 0.4 0 0.4 0.4 237 5 237 305 10 0 10 0 0.4 0 0.6 0.3 11/20/2004 11:10:00 12.2 1 14.5 9.5 11.1 1.1 13.3 8 0.4 0 0.4 0.4 237 5 240 305 10 0 10 0 0.4 0 0.6 0.3 11/20/2004 11:20:00 12.8 1.3 15.6 9.5 11.6 1.5 14.9 8.4 0.4 0 0.4 0.4 235 5 234 305 10 0 10 0 0.3 0 0.6 0.1 11/20/2004 11:30:00 13.9 1.4 17.2 10.3 12.9 1.4 16.4 9.5 0.4 0 0.4 0.4 234 5 242 305 10 0 10 0 0.2 0.1 0.6 0.1 11/20/2004 11:40:00 14.8 1.5 18.3 9.9 13.8 1.7 17.2 9.5 0.4 0 0.4 0.4 235 5 236 305 10 0 10 0 0.1 0 0.6 0.1 11/20/2004 11:50:00 14.5 1.3 17.6 10.3 13.4 1.5 16.1 9.5 0.4 0 0.4 0.4 234 4 238 305 10 0 9 0 0.2 0 0.6 0.1 11/20/2004 12:00:00 14.7 1.7 17.9 9.5 13.7 1.8 17.6 8.8 0.4 0 0.4 0.4 233 5 235 305 10 0 10 0 0.3 0 0.6 0.1 11/20/2004 12:10:00 14.8 1.4 17.9 11.1 13.9 1.7 17.2 9.5 0.4 0 0.4 0.4 233 5 237 305 10 0 9 0 0.3 0 0.6 0.1 11/20/2004 12:20:00 14.7 1.4 18.3 10.3 13.5 1.3 16.8 9.5 0.4 0 0.4 0.4 235 5 239 305 9 0 9 0 0.2 0 0.6 0.1 11/20/2004 12:30:00 15.1 1.7 18.7 11.1 14.1 1.7 18.3 9.5 0.4 0 0.4 0.4 234 5 238 305 9 0 9 0 0.3 0 0.6 0.3 11/20/2004 12:40:00 14.6 1.5 18.3 10.3 13.6 1.5 17.2 9.9 0.4 0 0.4 0.4 234 5 227 305 9 0 9 0 0.4 0 1 0.3 11/20/2004 12:50:00 14.8 1.2 17.6 10.7 13.8 1.3 17.2 9.9 0.4 0 0.4 0.4 229 5 229 305 9 0 9 0 0.5 0 1 0.3 11/20/2004 13:00:00 15.7 1.5 19.1 10.7 14.6 1.8 18.7 9.5 0.4 0 0.4 0.4 227 5 229 305 9 0 9 0 0.5 0 1 0.3 11/20/2004 13:10:00 15.6 1.5 18.7 11.5 14.4 1.7 18.3 9.9 0.4 0 0.4 0.4 227 5 230 305 9 0 9 0 0.5 0 1 0.3 11/20/2004 13:20:00 15.2 1.6 18.3 11.1 14.1 1.6 18.3 10.3 0.4 0 0.4 0.4 225 5 224 305 9 0 9 0 0.4 0 1 0.3 11/20/2004 13:30:00 15.5 1.3 17.9 11.5 14.4 1.6 17.6 10.3 0.4 0 0.4 0.4 227 5 230 305 9 0 9 0 0.3 0.1 0.8 0.1 11/20/2004 13:40:00 15.2 1.3 18.3 12.2 14.4 1.4 17.6 10.7 0.4 0 0.4 0.4 231 5 239 305 9 0 9 0 0.1 0.1 0.6 0.1 11/20/2004 13:50:00 14.9 1.5 17.6 11.5 13.9 1.5 17.6 10.3 0.4 0 0.4 0.4 233 5 242 305 9 0 9 0 0.2 0 0.6 0.1 11/20/2004 14:00:00 14.8 1.2 17.6 11.5 13.8 1.4 17.2 9.5 0.4 0 0.4 0.4 234 5 229 305 9 0 8 0 0.4 0 1 0.3 11/20/2004 14:10:00 14 1.4 16.8 10.3 13.1 1.5 16.4 9.1 0.4 0 0.4 0.4 230 5 232 305 8 0 8 0 0.4 0 1 0.3 11/20/2004 14:20:00 14.2 1.3 18.3 10.3 13.1 1.5 16.4 9.1 0.4 0 0.4 0.4 226 6 224 305 8 0 8 0 0.5 0 1 0.3 11/20/2004 14:30:00 15.2 1.4 18.3 11.1 14.1 1.6 17.2 9.5 0.4 0 0.4 0.4 224 5 226 305 8 0 8 0 0.5 0 1 0.3 11/20/2004 14:40:00 15 1.3 17.6 11.5 13.8 1.5 17.6 10.3 0.4 0 0.4 0.4 224 5 229 305 8 0 8 0 0.5 0 1 0.3 11/20/2004 14:50:00 15.3 1.4 19.1 11.5 14 1.5 18.3 9.9 0.4 0 0.4 0.4 223 5 224 305 8 0 8 0 0.5 0 1 0.3 11/20/2004 15:00:00 15 1.3 18.3 11.5 13.8 1.5 17.6 9.9 0.4 0 0.4 0.4 224 5 226 305 8 0 8 0 0.4 0 0.6 0.3 11/20/2004 15:10:00 14.7 1.6 17.9 10.7 13.6 1.7 17.6 9.1 0.4 0 0.4 0.4 226 5 232 305 8 0 8 0 0.5 0 0.6 0.3 11/20/2004 15:20:00 13.1 1.5 16.8 8.8 12.2 1.6 16.1 8 0.4 0 0.4 0.4 230 6 232 305 8 0 8 0 0.5 0 0.6 0.6 11/20/2004 15:30:00 13.4 1.7 16.8 8.4 12.2 1.8 16.4 7.6 0.4 0 0.4 0.4 226 6 233 305 8 0 8 0 0.5 0 0.6 0.3 11/20/2004 15:40:00 14 1.5 17.6 10.3 12.9 1.7 16.4 8.8 0.4 0 0.4 0.4 226 6 220 305 8 0 8 0 0.5 0 0.6 0.3 11/20/2004 15:50:00 14.5 1.6 18.3 9.9 13.2 1.7 17.9 8.4 0.4 0 0.4 0.4 226 5 229 305 8 0 7 0 0.5 0 1 0.3 11/20/2004 16:00:00 14.1 1.4 17.6 9.9 13 1.5 16.4 9.9 0.4 0 0.4 0.4 223 6 227 305 8 0 8 0 0.4 0 0.6 0.3 11/20/2004 16:10:00 15.2 1.5 19.5 11.8 14 1.7 19.1 9.5 0.4 0 0.4 0.4 225 5 226 305 8 0 8 0 0 0 0.3 -0.1 11/20/2004 16:20:00 15 1.5 19.1 11.1 13.8 1.7 18.3 10.3 0.4 0 0.4 0.4 224 5 228 305 8 0 8 0 0.2 0 0.6 0.1 11/20/2004 16:30:00 14.5 1.5 17.9 10.7 13.3 1.7 17.9 9.5 0.4 0 0.4 0.4 227 5 225 305 8 0 8 0 0.3 0 0.6 0.1 11/20/2004 16:40:00 13.6 1.4 16.4 9.1 12.4 1.5 16.4 8.4 0.4 0 0.4 0.4 225 5 230 305 7 0 7 0 0.2 0 0.6 0.1 11/20/2004 16:50:00 14 1.2 16.8 9.1 12.8 1.3 16.4 9.1 0.4 0 0.4 0.4 224 5 231 305 7 0 7 0 0.2 0 0.6 0.1 11/20/2004 17:00:00 14.2 1.3 17.6 9.5 12.9 1.4 16.4 8.4 0.4 0 0.4 0.4 224 5 225 305 8 0 7 0 0.3 0 0.6 0.1 11/20/2004 17:10:00 14.5 1.2 17.2 11.1 13.5 1.3 16.4 10.3 0.4 0 0.4 0.4 223 5 224 305 8 0 8 0 0.4 0 0.8 0.3 11/20/2004 17:20:00 14.2 1.6 18.3 9.9 13.1 1.6 17.2 9.1 0.4 0 0.4 0.4 225 6 237 305 8 0 8 0 0.4 0 0.6 0.3 11/20/2004 17:30:00 14.7 1.6 18.3 10.3 13.7 1.7 17.6 9.1 0.4 0 0.4 0.4 228 5 222 305 8 0 8 0 0.3 0 0.6 0.1 11/20/2004 17:40:00 14.2 1.3 17.2 9.1 13 1.5 16.4 8.8 0.4 0 0.4 0.4 226 5 229 305 8 0 8 0 0 0 0.6 0.1 11/20/2004 17:50:00 14.2 1.3 17.9 10.3 13.2 1.5 17.2 9.5 0.4 0 0.4 0.4 228 5 233 305 8 0 8 0 0 0 0.6 -0.1 11/20/2004 18:00:00 12.6 1.3 15.6 8.8 11.6 1.5 15.6 8 0.4 0 0.4 0.4 227 6 232 305 9 0 8 0 -0.1 0 0.3 -0.4 11/20/2004 18:10:00 14.6 1.3 17.6 10.7 13.6 1.5 17.2 9.1 0.4 0 0.4 0.4 229 5 230 305 9 0 9 0 0.1 0.1 0.6 0.1 11/20/2004 18:20:00 13.1 1.3 16.4 9.1 12.2 1.3 16.4 8.8 0.4 0 0.4 0.4 234 5 235 305 9 0 9 0 0.1 0.1 0.6 -0.1 11/20/2004 18:30:00 11.9 1 14.1 9.5 11.1 1 13.7 8 0.4 0 0.4 0.4 231 5 232 305 9 0 9 0 0 0.1 0.6 0.1 11/20/2004 18:40:00 12.3 1 14.9 9.1 11.4 1.1 14.5 8.4 0.4 0 0.4 0.4 228 5 238 305 9 0 9 0 0.3 0 0.8 0.1 11/20/2004 18:50:00 11.7 0.9 14.1 9.1 10.9 1 13.3 8.4 0.4 0 0.4 0.4 228 6 234 305 9 0 9 0 0.3 0 0.8 0.1 11/20/2004 19:00:00 12.7 1.3 15.6 9.1 11.8 1.4 14.9 8.4 0.4 0 0.4 0.4 228 6 234 305 9 0 9 0 0.1 0.1 0.6 0.1 11/20/2004 19:10:00 13.3 1.2 16.4 9.9 12.2 1.3 16.1 8.8 0.4 0 0.4 0.4 231 5 231 305 8 0 8 0 0.3 0 0.8 0.1 11/20/2004 19:20:00 12.7 1.5 16.4 9.1 11.7 1.7 15.6 7.6 0.4 0 0.4 0.4 228 6 220 305 8 0 8 0 0.2 0.1 0.6 0.1 11/20/2004 19:30:00 13.8 1.5 16.8 9.9 12.6 1.6 16.1 8.8 0.4 0 0.4 0.4 226 5 225 305 7 0 7 0 0.1 0.1 0.6 0.1 11/20/2004 19:40:00 12.6 1.3 16.1 8.8 11.6 1.3 14.9 8.4 0.4 0 0.4 0.4 225 6 224 305 7 0 7 0 0.1 0 0.3 0.1 11/20/2004 19:50:00 12.3 1.2 14.9 8.4 11.4 1.2 14.9 8 0.4 0 0.4 0.4 223 5 221 305 7 0 7 0 0 0 0.1 -0.1 11/20/2004 20:00:00 14 1.2 16.8 10.7 12.9 1.3 15.6 9.1 0.4 0 0.4 0.4 223 5 219 305 6 0 7 0 -0.1 0 0.3 -0.4 11/20/2004 20:10:00 13.8 1.2 16.1 9.9 13 1.3 16.1 9.5 0.4 0 0.4 0.4 220 4 220 305 6 0 6 0 -0.3 0 0.3 -0.4 11/20/2004 20:20:00 13 1 14.9 10.3 12 1.1 14.9 8.8 0.4 0 0.4 0.4 221 4 220 305 6 0 6 0 -0.3 0 0.3 -0.4 11/20/2004 20:30:00 11.7 1.1 14.1 9.1 10.7 1.2 14.1 8 0.4 0 0.4 0.4 222 5 220 305 6 0 6 0 -0.3 0 0.3 -0.4 11/20/2004 20:40:00 11.7 1 13.7 8.8 10.8 1 13.3 7.6 0.4 0 0.4 0.4 221 4 223 305 6 0 6 0 -0.3 0 0.3 -0.4 11/20/2004 20:50:00 11.2 0.7 13 9.1 10.6 1 12.6 7.6 0.4 0 0.4 0.4 221 4 223 305 6 0 6 0 -0.3 0 0.3 -0.4 11/20/2004 21:00:00 10.9 0.9 13 8.4 10.4 1 12.6 7.6 0.4 0 0.4 0.4 218 4 218 305 6 0 6 0 -0.3 0 0.1 -0.4 11/20/2004 21:10:00 9.8 0.6 11.5 8.4 9.4 0.7 11.5 6.8 0.4 0 0.4 0.4 217 4 217 305 6 0 6 0 -0.3 0 -0.1 -0.6 11/20/2004 21:20:00 9.6 0.7 11.5 7.6 9 0.8 11.1 6.5 0.4 0 0.4 0.4 213 4 208 305 6 0 6 0 -0.4 0 -0.4 -0.6 11/20/2004 21:30:00 9.1 0.8 10.7 6.8 8.5 0.9 10.7 6.1 0.4 0 0.4 0.4 210 5 214 305 7 0 7 0 -0.4 0 -0.4 -0.6 11/20/2004 21:40:00 9.1 0.5 10.3 6.8 8.7 0.6 9.9 6.5 0.4 0 0.4 0.4 208 3 212 305 7 0 7 0 -0.4 0 -0.4 -0.6 11/20/2004 21:50:00 9 0.4 9.9 8 8.7 0.4 9.9 7.6 0.4 0 0.4 0.4 205 3 205 305 7 0 7 0 -0.4 0.1 0.1 -0.6 11/20/2004 22:00:00 7.8 0.8 9.5 5.3 7.7 0.8 9.1 4.9 0.4 0 0.4 0.4 198 6 201 305 7 0 7 0 -0.7 0 -0.1 -1.1 11/20/2004 22:10:00 7.8 0.4 8.8 6.8 7.8 0.4 8.8 6.1 0.4 0 0.4 0.4 198 3 194 305 8 0 7 0 -0.4 0.1 0.3 -0.6 11/20/2004 22:20:00 7.6 0.3 8 6.8 7.6 0.3 8.4 6.1 0.4 0 0.4 0.4 195 2 198 305 8 0 8 0 -0.6 0 0.1 -0.8 11/20/2004 22:30:00 7.9 0.5 9.1 6.1 7.9 0.5 9.1 6.5 0.4 0 0.4 0.4 193 3 190 305 9 0 9 0 -0.3 0.1 0.3 -0.6 11/20/2004 22:40:00 6.6 0.7 8.4 4.6 6.8 0.7 8 4.9 0.4 0 0.4 0.4 189 5 198 305 9 0 9 0 -0.2 0.1 0.3 -0.4 11/20/2004 22:50:00 6.4 0.5 7.2 4.2 6.6 0.3 7.6 5.3 0.4 0 0.4 0.4 191 4 192 305 9 0 9 0 0.1 0.1 0.6 0.1 11/20/2004 23:00:00 6.8 0.2 7.2 6.1 6.9 0.3 7.6 6.1 0.4 0 0.4 0.4 192 2 192 305 10 0 10 0 0.3 0.2 1 0.1 11/20/2004 23:10:00 6.4 0.9 7.6 3 6.7 0.5 7.6 5.3 0.4 0 0.4 0.4 188 5 189 305 10 0 10 0 0.5 0 1 0.3 11/20/2004 23:20:00 5.6 1 8.8 3.4 7.8 0.7 9.5 6.1 0.4 0 0.4 0.4 176 6 186 305 11 0 10 0 1.2 0.2 2 0.6 11/20/2004 23:30:00 5.5 0.8 8.4 3.4 8.2 0.8 10.3 5.7 0.4 0 0.4 0.4 174 6 184 305 11 0 11 0 1.4 0 2 1.3 11/20/2004 23:40:00 5.5 1 8.8 3.8 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 174 7 155 305 11 0 11 0 1.3 0.1 2 1 11/20/2004 23:50:00 6.1 1.4 9.9 3 7.9 0.9 9.9 5.7 0.4 0 0.4 0.4 176 8 186 305 11 0 11 0 1.4 0 2 1.3 11/21/2004 00:00:00 6 1.3 10.3 3 7.4 1.4 11.1 5.3 0.4 0 0.4 0.4 169 9 194 305 11 0 11 0 1.1 0.3 2.2 0.6 11/21/2004 00:10:00 7 1.5 11.1 3.8 9.3 1 11.5 6.8 0.4 0 0.4 0.4 177 6 188 305 12 0 12 0 2.2 0 2.7 2 11/21/2004 00:20:00 7.6 1.5 11.5 4.2 9.5 1 11.5 6.8 0.4 0 0.4 0.4 180 5 192 305 12 0 12 0 2.3 0.1 2.9 2.2 11/21/2004 00:30:00 6.1 1.1 9.5 3 8.8 1.5 11.8 5.7 0.4 0 0.4 0.4 172 6 184 305 12 0 12 0 2.1 0.2 2.7 1.5 11/21/2004 00:40:00 7 1.2 10.7 4.2 9.3 1.3 13 6.8 0.4 0 0.4 0.4 168 7 165 305 12 0 12 0 1.9 0.2 2.7 1.5 11/21/2004 00:50:00 8.1 1.1 11.8 4.9 11.9 0.9 14.1 9.5 0.4 0 0.4 0.4 174 5 183 305 12 0 12 0 2.5 0 2.9 2.2 11/21/2004 01:00:00 8.9 1.5 12.6 5.3 10.7 1.2 14.1 8 0.4 0 0.4 0.4 180 6 192 305 12 0 12 0 2.3 0.1 2.9 2.2 11/21/2004 01:10:00 7.8 1.6 11.8 4.2 10 1 12.2 7.2 0.4 0 0.4 0.4 178 7 183 305 12 0 12 0 2.2 0 2.7 2.2 11/21/2004 01:20:00 7.8 1.3 10.7 4.9 10.1 0.9 13 7.6 0.4 0 0.4 0.4 177 7 187 305 12 0 12 0 2.3 0 2.9 2.2 11/21/2004 01:30:00 7.3 1.1 10.7 4.6 9.6 1.3 12.6 6.8 0.4 0 0.4 0.4 168 8 166 305 12 0 12 0 2.3 0.2 2.9 2 11/21/2004 01:40:00 6.9 1 9.9 4.6 10 0.9 13 7.6 0.4 0 0.4 0.4 171 6 165 305 12 0 12 0 2.3 0 2.9 2.2 11/21/2004 01:50:00 8.1 1.2 11.5 4.9 11.3 0.9 14.5 8 0.4 0 0.4 0.4 176 6 182 305 12 0 12 0 2.5 0.1 3.2 2.2 11/21/2004 02:00:00 8.3 1.1 11.8 5.7 12.1 1 14.1 8.4 0.4 0 0.4 0.4 173 5 175 305 11 0 12 0 2.5 0.1 2.9 2.2 11/21/2004 02:10:00 7.9 1.1 11.1 5.3 11.5 1 14.1 8.8 0.4 0 0.4 0.4 171 5 158 305 11 0 11 0 2.2 0 2.7 2.2 11/21/2004 02:20:00 7.9 1 10.7 5.3 11.4 1 13.7 8.4 0.4 0 0.4 0.4 170 5 165 305 12 0 12 0 2.2 0 2.7 2.2 11/21/2004 02:30:00 7.9 1.2 13 4.9 11.6 1 14.5 8.8 0.4 0 0.4 0.4 171 5 183 305 12 0 12 0 2.4 0 2.9 2.2 11/21/2004 02:40:00 6.6 1 9.9 4.6 10.3 0.8 13 7.6 0.4 0 0.4 0.4 172 4 174 305 13 0 13 0 2.4 0.1 2.7 2.2 11/21/2004 02:50:00 6 1 10.7 3.4 9.4 1.1 11.5 6.1 0.4 0 0.4 0.4 169 5 163 305 13 0 13 0 2.2 0 2.7 2.2 11/21/2004 03:00:00 6.4 1.2 8.8 3.4 7 0.8 10.3 4.9 0.4 0 0.4 0.4 160 6 141 305 13 0 13 0 1.9 0.1 2.5 1.5 11/21/2004 03:10:00 7 1.3 9.9 4.2 8.3 0.8 10.3 5.7 0.4 0 0.4 0.4 161 7 155 305 13 0 13 0 2 0 2.5 1.7 11/21/2004 03:20:00 8 1.5 11.5 4.6 7.9 1.1 12.2 4.9 0.4 0 0.4 0.4 152 7 156 305 13 0 13 0 1.6 0.1 2.2 1.5 11/21/2004 03:30:00 8.7 1 11.5 6.5 8.5 0.8 10.7 6.1 0.4 0 0.4 0.4 147 7 154 305 13 0 13 0 1.6 0 2.2 1.5 11/21/2004 03:40:00 7.9 1 11.1 4.9 7.9 1 10.7 4.9 0.4 0 0.4 0.4 141 8 149 305 13 0 13 0 1.4 0.1 2 1.3 11/21/2004 03:50:00 7.5 1.1 10.3 4.9 7.4 1 9.9 5.3 0.4 0 0.4 0.4 143 9 152 305 13 0 13 0 1.3 0 2 1.3 11/21/2004 04:00:00 8.5 1 11.1 4.6 8.3 1 11.1 6.1 0.4 0 0.4 0.4 146 10 138 305 13 0 13 0 1.4 0 2 1.3 11/21/2004 04:10:00 9.9 1.2 13 6.5 9.4 1 12.6 6.8 0.4 0 0.4 0.4 148 6 150 305 13 0 13 0 1.5 0 2 1.3 11/21/2004 04:20:00 10 1.3 13 4.9 9.7 1 12.2 7.2 0.4 0 0.4 0.4 149 8 144 305 14 0 14 0 1.6 0 2.2 1.5 11/21/2004 04:30:00 9.7 1.2 12.6 6.8 9.3 1 12.2 6.8 0.4 0 0.4 0.4 150 7 155 305 14 0 14 0 1.6 0 2.2 1.5 11/21/2004 04:40:00 9.3 1.2 12.2 6.1 9 1.1 12.2 6.8 0.4 0 0.4 0.4 149 7 152 305 14 0 14 0 1.6 0 2 1.5 11/21/2004 04:50:00 7.7 1.3 11.1 4.9 7.5 1.2 11.1 4.9 0.4 0 0.4 0.4 145 9 144 305 14 0 14 0 1.4 0 2 1.3 11/21/2004 05:00:00 7.1 1.1 9.5 4.2 6.9 1.1 9.9 4.2 0.4 0 0.4 0.4 137 9 137 305 14 0 14 0 1.3 0 2 1.3 11/21/2004 05:10:00 7.4 0.9 9.5 5.3 7.2 0.8 9.9 5.3 0.4 0 0.4 0.4 137 7 145 305 14 0 14 0 1.4 0 2 1.3 11/21/2004 05:20:00 8 1 10.3 5.3 7.8 1 10.3 4.9 0.4 0 0.4 0.4 137 7 143 305 14 0 14 0 1.4 0 2 1.3 11/21/2004 05:30:00 9.4 0.9 12.2 6.5 9.1 0.8 11.8 6.8 0.4 0 0.4 0.4 136 6 148 305 14 0 14 0 1.4 0 2 1.3 11/21/2004 05:40:00 9.5 1 12.2 6.5 9.3 1 11.8 6.8 0.4 0 0.4 0.4 136 6 145 305 14 0 14 0 1.5 0 2 1.3 11/21/2004 05:50:00 8.6 1.3 12.2 5.7 8.4 1.2 11.5 5.7 0.4 0 0.4 0.4 132 8 132 305 14 0 14 0 1.5 0 2 1.3 11/21/2004 06:00:00 10 1.3 13 6.8 9.7 1.3 13.3 5.7 0.4 0 0.4 0.4 132 9 138 305 14 0 14 0 1.5 0 2 1.3 11/21/2004 06:10:00 10 1.5 13.3 6.5 9.7 1.4 13 6.5 0.4 0 0.4 0.4 132 9 136 305 14 0 14 0 1.5 0 2 1.3 11/21/2004 06:20:00 10.2 1.2 13 7.2 9.9 1.1 12.2 6.8 0.4 0 0.4 0.4 135 7 129 305 14 0 14 0 1.6 0 2.2 1.5 11/21/2004 06:30:00 10 1.3 13 6.1 9.7 1.3 13 6.8 0.4 0 0.4 0.4 134 11 131 305 14 0 14 0 1.6 0.1 2.2 1.5 11/21/2004 06:40:00 8.6 1.6 12.6 4.6 8.4 1.6 12.6 4.2 0.4 0 0.4 0.4 132 13 136 305 14 0 14 0 1.6 0 2.2 1.5 11/21/2004 06:50:00 8.1 1.6 11.5 4.6 7.7 1.5 12.2 3.8 0.4 0 0.4 0.4 131 15 130 305 14 0 14 0 1.6 0 2.2 1.5 11/21/2004 07:00:00 6.5 1.8 11.5 1.9 6.6 1.9 12.2 2.3 0.4 0 0.4 0.4 128 19 113 305 14 0 14 0 1.6 0.1 2.2 1.5 11/21/2004 07:10:00 5.6 2 10.7 0.7 5.6 2 11.5 2.3 0.4 0 0.4 0.4 127 24 166 305 14 0 14 0 1.6 0 2.2 1.5 11/21/2004 07:20:00 7.9 2.3 13.3 2.6 7.5 2.1 13.7 2.3 0.4 0 0.4 0.4 123 20 136 305 14 0 14 0 1.5 0 2 1.3 11/21/2004 07:30:00 7.1 1.9 11.5 2.3 6.9 1.7 11.1 3.8 0.4 0 0.4 0.4 123 17 124 305 14 0 14 0 1.5 0 2 1.3 11/21/2004 07:40:00 6.9 2.4 14.1 2.6 6.6 2.2 13 2.3 0.4 0 0.4 0.4 123 22 157 305 14 0 14 0 1.4 0 2 1.3 11/21/2004 07:50:00 6.6 1.8 12.6 2.6 6.7 1.7 12.2 3.8 0.4 0 0.4 0.4 127 22 155 305 14 0 14 0 1.5 0 2 1.3 11/21/2004 08:00:00 6.5 2.3 13.3 1.9 6.4 2.1 12.6 2.3 0.4 0 0.4 0.4 121 23 142 305 14 0 14 0 1.5 0 2 1.3 11/21/2004 08:10:00 8.5 2.5 15.6 2.6 8.3 2.3 15.6 3.8 0.4 0 0.4 0.4 127 22 143 305 14 0 14 0 1.6 0 2 1.5 11/21/2004 08:20:00 10.2 2.1 15.6 4.2 10.1 2 17.6 4.2 0.4 0 0.4 0.4 127 16 126 305 14 0 14 0 1.6 0 2.2 1.5 11/21/2004 08:30:00 9.4 2.1 14.5 4.9 9.4 2.1 15.6 4.9 0.4 0 0.4 0.4 127 17 142 305 14 0 14 0 1.6 0.1 2.2 1.5 11/21/2004 08:40:00 7.9 1.7 12.2 3.8 7.8 1.6 12.2 4.6 0.4 0 0.4 0.4 118 20 108 305 14 0 14 0 1.6 0 2.2 1.5 11/21/2004 08:50:00 6 1.7 10.7 1.9 5.9 1.5 9.5 1.9 0.4 0 0.4 0.4 100 29 133 305 14 0 14 0 1.7 0.1 2.2 1.5 11/21/2004 09:00:00 8.8 2.6 15.3 0.4 8.7 2.5 15.3 2.3 0.4 0 0.4 0.4 62 17 57 305 14 0 13 0 1.7 0.1 2.2 1.5 11/21/2004 09:10:00 10.1 2.6 17.6 3 9.7 2.6 17.2 3.8 0.4 0 0.4 0.4 64 19 65 305 13 0 13 0 1.7 0.1 2.2 1.5 11/21/2004 09:20:00 7.7 2.5 13.7 1.1 7.6 2.2 14.9 2.6 0.4 0 0.4 0.4 82 29 120 305 13 0 13 0 1.6 0 2.2 1.5 11/21/2004 09:30:00 6.9 2.6 15.3 0.7 6.7 2.5 14.5 2.3 0.4 0 0.4 0.4 90 32 76 305 13 0 13 0 1.6 0 2.2 1.5 11/21/2004 09:40:00 9.1 2.5 15.6 3 9.1 2.6 17.2 3.4 0.4 0 0.4 0.4 72 26 75 305 13 0 12 0 1.6 0 2.2 1.5 11/21/2004 09:50:00 9.2 2.9 18.7 3 9.1 3.1 18.3 1.9 0.4 0 0.4 0.4 68 24 65 305 12 0 12 0 1.3 0.2 2 1 11/21/2004 10:00:00 11.4 2.8 18.3 4.9 11.3 2.9 18.3 4.9 0.4 0 0.4 0.4 64 15 62 305 12 0 12 0 1.3 0.1 2 1 11/21/2004 10:10:00 14.2 2.3 20.2 9.9 14 2.4 20.2 8.4 0.4 0 0.4 0.4 71 11 83 305 12 0 12 0 1.4 0 2 1.3 11/21/2004 10:20:00 13.1 2.6 22.6 7.2 13 2.7 22.9 7.2 0.4 0 0.4 0.4 68 13 71 305 12 0 12 0 1.5 0 2 1.3 11/21/2004 10:30:00 12.7 3.2 22.9 3.4 12.5 3.2 22.1 4.2 0.4 0 0.4 0.4 71 20 77 305 12 0 12 0 1.4 0 1.7 1.3 11/21/2004 10:40:00 14.4 3.2 22.1 6.8 14.3 3.5 22.6 5.3 0.4 0 0.4 0.4 72 15 82 305 12 0 12 0 1.1 0 1.5 1 11/21/2004 10:50:00 14.3 2.7 22.1 7.6 13.9 2.7 20.6 6.8 0.4 0 0.4 0.4 69 12 75 305 12 0 12 0 1 0 1.5 1 11/21/2004 11:00:00 13.1 2.6 19.9 6.1 13 2.6 19.5 6.5 0.4 0 0.4 0.4 70 16 73 305 12 0 12 0 1 0 1.5 0.8 11/21/2004 11:10:00 12.9 2 19.9 7.6 12.7 2.1 19.5 7.6 0.4 0 0.4 0.4 70 12 64 305 12 0 12 0 1 0 1.5 0.8 11/21/2004 11:20:00 13 2.3 19.9 7.6 12.6 2.4 20.6 6.1 0.4 0 0.4 0.4 68 13 72 305 12 0 12 0 1 0 1.5 1 11/21/2004 11:30:00 12.7 3.2 21 5.3 12.4 3.5 21 4.9 0.4 0 0.4 0.4 66 17 62 305 12 0 13 0 1.2 0.1 1.7 1 11/21/2004 11:40:00 13.5 3.6 24.4 6.5 13.1 3.6 22.9 6.1 0.4 0 0.4 0.4 65 22 75 305 12 0 12 0 1.2 0.1 1.7 1 11/21/2004 11:50:00 14.1 3.8 24 6.5 13.8 4 24 4.9 0.4 0 0.4 0.4 69 22 87 305 12 0 12 0 1.2 0.1 1.5 1 11/21/2004 12:00:00 14.1 3.3 22.6 4.2 13.8 3.5 24 4.2 0.4 0 0.4 0.4 68 21 96 305 12 0 12 0 1.2 0.1 1.7 1 11/21/2004 12:10:00 14.7 3.3 24.8 6.5 14.8 3.6 23.7 4.9 0.4 0 0.4 0.4 68 19 65 305 12 0 12 0 1.2 0.1 1.7 1 11/21/2004 12:20:00 15 4.1 24.4 5.3 14.8 4.1 24.8 6.1 0.4 0 0.4 0.4 67 19 80 305 12 0 12 0 1.2 0.1 1.7 1 11/21/2004 12:30:00 14.4 3.8 24 3.4 14.3 4 25.6 3 0.4 0 0.4 0.4 67 19 56 305 11 0 11 0 1.2 0.1 1.5 1 11/21/2004 12:40:00 14.6 3.2 23.3 6.8 14.6 3.2 23.3 5.7 0.4 0 0.4 0.4 64 16 73 305 11 0 11 0 1.2 0.1 1.5 1 11/21/2004 12:50:00 15.3 2.8 21.4 8 15.2 2.9 21.8 6.8 0.4 0 0.4 0.4 69 13 74 305 11 0 11 0 1.2 0.1 1.5 1 11/21/2004 13:00:00 16.5 2.6 23.3 9.9 16.1 2.7 23.7 9.1 0.4 0 0.4 0.4 73 12 62 305 10 0 10 0 1.3 0 2 1.3 11/21/2004 13:10:00 16.3 3.3 26 9.1 16 3.6 27.5 8.8 0.4 0 0.4 0.4 73 15 84 305 10 0 9 0 1.4 0 2 1.3 11/21/2004 13:20:00 16.7 2.5 24.4 11.8 16.5 2.5 23.3 9.9 0.4 0 0.4 0.4 71 10 69 305 9 0 9 0 1.3 0 2 1.3 11/21/2004 13:30:00 17 2.4 24.4 9.1 16.7 2.5 24.8 9.9 0.4 0 0.4 0.4 70 10 57 305 8 0 8 0 1.3 0.1 2 1 11/21/2004 13:40:00 16.9 2.7 24.4 9.9 16.5 2.6 25.2 9.1 0.4 0 0.4 0.4 72 11 66 305 8 0 8 0 1.2 0.1 1.5 0.8 11/21/2004 13:50:00 17.8 2.5 25.2 10.7 17.5 2.7 25.2 9.5 0.4 0 0.4 0.4 72 10 71 305 9 0 8 0 0.7 0.1 1.3 0.3 11/21/2004 14:00:00 18 2.1 23.3 12.6 17.7 2.1 23.3 12.2 0.4 0 0.4 0.4 73 8 83 305 10 0 9 0 0.3 0 0.8 0.1 11/21/2004 14:10:00 18 1.8 22.9 12.6 17.6 2 22.6 12.2 0.4 0 0.4 0.4 72 7 77 305 12 0 12 0 0.4 0 1 0.3 11/21/2004 14:20:00 17.6 2.1 23.3 13 17.2 2.2 22.9 13 0.4 0 0.7 0.4 72 8 75 305 13 0 12 0 0.4 0 1 0.3 11/21/2004 14:30:00 17.8 1.7 22.6 13.3 17.5 1.9 22.9 12.6 0.4 0 0.4 0.4 72 7 75 305 13 0 13 0 0.4 0 1 0.3 11/21/2004 14:40:00 18.5 1.9 23.7 13.7 18 1.9 22.1 14.1 0.4 0 0.7 0.4 72 8 69 305 14 0 14 0 0.5 0 1 0.3 11/21/2004 14:50:00 18.5 1.7 23.3 13 18.2 1.8 22.6 13 0.4 0 0.4 0.4 73 7 81 305 14 0 14 0 0.5 0 1 0.3 11/21/2004 15:00:00 18.6 1.9 24.8 14.1 18.3 2 24 13.7 0.4 0 0.4 0.4 70 7 81 305 15 0 15 0 0.5 0 1 0.3 11/21/2004 15:10:00 19.1 2 25.6 13.3 18.6 2.1 25.6 13 0.4 0 0.4 0.4 73 7 72 305 15 0 15 0 0.5 0 1 0.3 11/21/2004 15:20:00 19.5 1.7 24.4 15.3 19.2 1.8 25.6 15.3 0.4 0 0.4 0.4 70 7 66 305 15 0 15 0 0.5 0 1 0.3 11/21/2004 15:30:00 20.4 1.6 24 16.1 20.1 1.7 24 15.3 0.4 0 0.4 0.4 69 6 71 305 15 0 15 0 0.5 0 1 0.3 11/21/2004 15:40:00 20.7 1.6 24.4 15.3 20.4 1.7 25.2 14.9 0.4 0 0.4 0.4 69 6 71 305 15 0 15 0 0.5 0 1 0.3 11/21/2004 15:50:00 21.4 1.6 25.2 17.2 21.1 1.7 25.6 16.1 0.4 0 0.4 0.4 68 6 69 305 15 0 15 0 0.6 0 1 0.6 11/21/2004 16:00:00 21.8 1.5 25.2 17.2 21.3 1.7 25.6 16.1 0.4 0 0.4 0.4 67 5 64 305 15 0 15 0 0.6 0 1 0.6 11/21/2004 16:10:00 22.3 1.7 27.5 18.3 21.9 1.7 27.1 17.2 0.4 0 0.4 0.4 68 5 71 305 15 0 15 0 0.6 0.1 1.3 0.6 11/21/2004 16:20:00 22.5 1.5 26.8 17.9 22.1 1.7 27.1 17.9 0.4 0 0.4 0.4 68 5 64 305 15 0 15 0 0.7 0.1 1.3 0.6 11/21/2004 16:30:00 22.1 1.6 27.1 16.4 21.8 1.7 26.3 16.1 0.4 0 0.4 0.4 68 5 68 305 15 0 15 0 0.6 0.1 1 0.6 11/21/2004 16:40:00 22.5 1.5 26 18.3 22.1 1.7 26.3 17.9 0.4 0 0.4 0.4 67 5 66 305 15 0 15 0 0.5 0 1 0.3 11/21/2004 16:50:00 22.1 1.4 26 18.3 21.6 1.4 25.6 17.6 0.4 0 0.4 0.4 69 4 69 305 15 0 15 0 0.3 0 0.8 0.1 11/21/2004 17:00:00 21.4 1.6 25.2 17.2 20.7 1.7 24.8 16.8 0.4 0 0.4 0.4 68 5 71 305 15 0 15 0 0.3 0 0.8 0.3 11/21/2004 17:10:00 21.5 1.5 25.2 17.2 21 1.7 24.8 16.1 0.4 0 0.4 0.4 68 5 72 305 15 0 15 0 0.4 0 1 0.3 11/21/2004 17:20:00 21.6 1.5 25.2 17.6 21.1 1.6 24.8 16.4 0.4 0 0.4 0.4 68 5 67 305 15 0 15 0 0.4 0 0.8 0.3 11/21/2004 17:30:00 21.9 1.5 26.3 17.6 21.6 1.6 25.6 17.6 0.4 0 0.4 0.4 68 5 59 305 15 0 15 0 0.4 0 1 0.3 11/21/2004 17:40:00 22.6 1.7 26.3 18.3 22.2 1.7 26.3 17.6 0.4 0 0.4 0.4 68 5 70 305 15 0 15 0 0.5 0 1 0.3 11/21/2004 17:50:00 23.1 1.5 27.5 18.3 22.8 1.7 27.1 17.9 0.4 0 0.4 0.4 68 5 67 305 15 0 15 0 0.5 0 1 0.6 11/21/2004 18:00:00 23.1 1.6 27.5 19.5 22.5 1.6 27.1 18.3 0.4 0 0.4 0.4 69 5 66 305 15 0 15 0 0.5 0 1 0.3 11/21/2004 18:10:00 23.6 1.7 27.9 17.9 22.9 1.9 28.7 17.6 0.4 0 0.4 0.4 67 5 61 305 15 0 15 0 0.5 0 1 0.6 11/21/2004 18:20:00 21.7 1.8 26.3 17.2 21.1 1.8 26.3 16.8 0.4 0 0.4 0.4 66 5 65 305 15 0 15 0 0.5 0 1 0.3 11/21/2004 18:30:00 22.7 2 27.9 17.2 22.2 2.1 27.5 16.8 0.4 0 0.4 0.4 66 5 65 305 15 0 15 0 0.5 0 1 0.3 11/21/2004 18:40:00 22.9 1.5 27.5 18.3 22.5 1.7 26.3 18.3 0.4 0 0.4 0.4 68 4 64 305 15 0 15 0 0.5 0 1 0.6 11/21/2004 18:50:00 21.9 1.7 26 17.6 21.6 1.8 26.3 16.8 0.4 0 0.4 0.4 68 5 72 305 15 0 15 0 0.5 0 1 0.6 11/21/2004 19:00:00 22.2 1.7 27.1 17.6 21.9 1.9 27.1 17.2 0.4 0 0.4 0.4 67 4 70 305 15 0 15 0 0.6 0 1.3 0.6 11/21/2004 19:10:00 22.3 1.5 26.3 18.3 21.9 1.7 27.1 17.9 0.4 0 0.4 0.4 67 5 64 305 15 0 15 0 0.7 0 1.3 0.6 11/21/2004 19:20:00 22.6 1.6 27.9 17.6 22.3 1.7 28.7 17.6 0.4 0 0.4 0.4 67 5 71 305 15 0 15 0 0.9 0 1.5 0.8 11/21/2004 19:30:00 22.9 1.6 27.1 17.9 22.6 1.8 27.9 17.9 0.4 0 0.4 0.4 67 5 62 305 15 0 15 0 1 0 1.5 0.8 11/21/2004 19:40:00 22.6 1.5 27.1 17.6 22.2 1.8 27.9 17.6 0.4 0 0.4 0.4 67 5 64 305 15 0 15 0 1 0 1.5 1 11/21/2004 19:50:00 22.4 1.6 26 17.9 22.2 1.7 27.1 17.9 0.4 0 0.4 0.4 67 5 68 305 15 0 15 0 1 0 1.5 0.8 11/21/2004 20:00:00 22.2 1.6 26 17.2 22.2 1.6 26 17.2 0.4 0 0.4 0.4 68 5 72 305 15 0 16 0 0.9 0 1.3 0.8 11/21/2004 20:10:00 21.2 1.5 25.2 16.4 21.4 1.6 26.3 16.1 0.4 0 0.4 0.4 68 6 67 305 15 0 15 0 0.9 0 1.3 0.8 11/21/2004 20:20:00 20.1 1.7 24.4 16.1 20.3 1.7 24.8 15.6 0.4 0 0.4 0.4 69 6 71 305 15 0 15 0 0.8 0 1.3 0.6 11/21/2004 20:30:00 19.8 1.4 24 15.6 19.8 1.6 23.3 15.3 0.4 0 0.4 0.4 70 6 78 305 15 0 15 0 0.9 0 1.3 0.8 11/21/2004 20:40:00 19.3 1.8 23.7 13.3 19.1 2 26 13.3 0.4 0 0.7 0.4 71 7 78 305 21 24 103 0 1 0 1.3 1 11/21/2004 20:50:00 19.5 1.8 23.7 14.5 19.2 2 24.4 13.7 0.4 0 0.4 0.4 74 8 84 305 109 32 105 0 1 0 1.3 1 11/21/2004 21:00:00 19.4 1.7 24 14.5 19.4 2 24.8 14.1 0.4 0 0.4 0.4 70 7 62 305 98 4 98 0 1.1 0 1.5 1 11/21/2004 21:10:00 19 1.6 24 15.3 18.7 1.7 23.7 13.7 0.4 0 0.4 0.4 70 7 79 305 105 3 101 0 1.2 0.1 1.7 1 11/21/2004 21:20:00 18.1 2.1 24 11.5 17.8 2.2 24 11.8 0.4 0 0.4 0.4 69 8 71 305 113 2 115 0 1.4 0.1 2.2 1.3 11/21/2004 21:30:00 18.2 2.7 27.5 10.3 18 2.7 26.8 9.5 0.4 0 0.4 0.4 69 10 73 305 118 1 119 0 1.7 0.1 2.2 1.5 11/21/2004 21:40:00 18.4 2.7 25.2 10.7 18.3 2.7 27.1 11.8 0.4 0 0.4 0.4 68 10 66 305 119 0 117 0 1.8 0.1 2.2 1.5 11/21/2004 21:50:00 16.4 4.1 28.7 5.7 16.3 4.3 30.2 5.7 0.4 0 0.4 0.4 68 17 81 305 116 1 116 0 1.9 0 2.5 1.7 11/21/2004 22:00:00 15 4.5 30.6 3.8 14.6 4.9 27.9 1.5 0.4 0 0.4 0.4 68 22 68 305 114 1 115 0 2.1 0.1 2.7 2 11/21/2004 22:10:00 15.7 4.3 29.1 4.9 15.3 4.5 27.9 4.9 0.4 0 0.4 0.4 69 22 82 305 113 1 113 0 2.2 0 2.7 2 11/21/2004 22:20:00 14.3 4.7 28.7 4.6 14.3 4.7 28.3 6.1 0.4 0 0.4 0.4 70 22 78 305 115 0 115 0 2.2 0.1 2.7 2.2 11/21/2004 22:30:00 13.9 4.1 26.3 3.4 13.8 4.5 28.7 3.4 0.4 0 0.4 0.4 67 22 75 305 115 0 114 0 2.1 0 2.7 1.7 11/21/2004 22:40:00 13.3 4.3 26.3 5.7 12.8 4.5 27.9 4.9 0.4 0 0.4 0.4 70 22 69 305 115 0 116 0 1.9 0.1 2.5 1.7 11/21/2004 22:50:00 12.3 4.1 27.1 3.4 11.8 4.3 27.9 3.4 0.4 0 0.4 0.4 76 27 57 305 115 1 114 0 2 0 2.5 2 11/21/2004 23:00:00 14.4 4 26 3.8 13.9 4.3 25.6 2.6 0.4 0 0.4 0.4 70 22 71 305 115 2 117 0 2 0 2.5 2 11/21/2004 23:10:00 13.7 3.5 26.3 5.7 13.4 3.8 24.4 4.9 0.4 0 0.4 0.4 70 23 45 305 116 1 115 0 1.7 0.1 2.5 1.5 11/21/2004 23:20:00 12.4 4.1 22.6 3.4 12 4.1 22.1 1.9 0.4 0 0.4 0.4 80 29 61 305 115 1 115 0 1.6 0 2.2 1.3 11/21/2004 23:30:00 10.1 2.9 22.6 2.3 9.7 3.1 24 3.4 0.4 0 0.4 0.4 82 29 99 305 115 1 116 0 1.3 0 2 1.3 11/21/2004 23:40:00 9.2 2.7 17.6 3 8.8 2.7 17.9 3 0.4 0 0.4 0.4 86 30 67 305 115 1 114 0 1.3 0 2 1.3 11/21/2004 23:50:00 8.1 2.9 14.9 1.1 8 2.8 15.6 1.5 0.4 0 0.4 0.4 106 36 111 305 115 1 115 0 1.3 0.1 2 1 11/22/2004 00:00:00 9.6 3.2 18.7 2.3 9.2 3.2 17.9 2.6 0.4 0 0.4 0.4 110 24 96 305 115 1 115 0 1.2 0.1 1.7 1 11/22/2004 00:10:00 10.4 2.5 18.7 5.3 10.2 2.7 18.3 4.9 0.4 0 0.4 0.4 123 21 106 305 115 1 116 0 1 0 1.3 0.8 11/22/2004 00:20:00 11.7 2.4 21 6.5 11.3 2.4 17.6 6.8 0.4 0 0.4 0.4 123 16 129 305 118 1 118 0 0.8 0 1.3 0.6 11/22/2004 00:30:00 12.3 2.4 17.9 5.3 12 2.2 17.6 6.1 0.4 0 0.4 0.4 124 13 129 305 118 0 118 0 0.7 0.1 1 0.6 11/22/2004 00:40:00 13.3 2.2 21 8.4 13.2 2.3 19.9 8 0.4 0 0.4 0.4 130 15 135 305 118 0 119 0 0.7 0.1 1 0.6 11/22/2004 00:50:00 14.7 2.1 21.8 9.9 14.4 2 19.9 9.9 0.4 0 0.4 0.4 133 11 146 305 119 0 119 0 0.9 0 1.3 0.8 11/22/2004 01:00:00 14.4 1.6 18.3 9.9 14.1 1.5 17.6 9.1 0.4 0 0.4 0.4 132 8 126 305 119 0 119 0 0.9 0 1.3 0.8 11/22/2004 01:10:00 13.8 1.4 17.2 9.9 13.5 1.5 17.6 8.8 0.4 0 0.4 0.4 135 7 131 305 120 0 121 0 0.9 0 1.3 0.8 11/22/2004 01:20:00 13.7 1.9 18.3 6.5 13.7 2 17.6 7.2 0.4 0 0.4 0.4 138 10 135 305 119 0 120 0 0.9 0 1 0.8 11/22/2004 01:30:00 13 2 17.6 8.4 13 1.9 18.3 8.8 0.4 0 0.4 0.4 145 12 150 305 119 0 119 0 1 0 1.5 1 11/22/2004 01:40:00 12.5 1.8 17.2 8.4 12.5 1.7 17.6 8.8 0.4 0 0.4 0.4 149 10 146 305 119 0 119 0 1 0 1.3 1 11/22/2004 01:50:00 13.3 2.2 17.6 8 13.2 1.7 17.6 8.8 0.4 0 0.4 0.4 149 10 152 305 119 0 119 0 1.1 0 1.5 1 11/22/2004 02:00:00 12.4 1.9 16.8 7.6 12.6 1.7 17.2 8.4 0.4 0 0.4 0.4 153 10 143 305 119 0 119 0 1.2 0.1 1.5 1 11/22/2004 02:10:00 12.9 2.1 17.9 7.6 13.6 1.9 18.7 8.8 0.4 0 0.4 0.4 159 9 155 305 119 0 119 0 1.2 0.1 1.7 1 11/22/2004 02:20:00 13.1 2 17.9 8.8 14.3 1.8 19.1 10.3 0.4 0 0.4 0.4 161 8 160 305 119 0 119 0 1.3 0 1.7 1.3 11/22/2004 02:30:00 12.8 2.1 18.7 7.6 14.6 1.6 18.3 11.1 0.4 0 0.4 0.4 163 7 159 305 120 0 120 0 1.4 0 2 1.3 11/22/2004 02:40:00 12.7 2 17.6 8.4 14.6 1.3 17.9 11.1 0.4 0 0.4 0.4 164 7 155 305 120 0 120 0 1.3 0 1.7 1.3 11/22/2004 02:50:00 13 1.9 17.2 9.1 16.1 1.6 20.6 11.5 0.4 0 0.4 0.4 166 5 162 305 120 0 120 0 1.2 0.1 2 1 11/22/2004 03:00:00 13.7 1.7 19.1 9.1 17.4 1.6 21.8 12.6 0.4 0 0.4 0.4 168 6 181 305 120 0 120 0 1.4 0 2 1.3 11/22/2004 03:10:00 14 2.1 20.6 9.5 17.1 1.9 23.7 13 0.4 0 0.4 0.4 171 7 187 305 120 0 120 0 1.4 0 2 1.3 11/22/2004 03:20:00 14.3 1.9 20.6 9.1 17.9 2 22.6 11.8 0.4 0 0.4 0.4 169 7 166 305 120 0 120 0 1.5 0 2 1.3 11/22/2004 03:30:00 13.2 2 21.4 8.8 16.4 1.7 22.1 12.2 0.4 0 0.4 0.4 171 7 181 305 121 0 121 0 1.6 0 2.2 1.5 11/22/2004 03:40:00 13.4 2.1 19.1 9.1 16.2 1.8 22.1 11.5 0.4 0 0.4 0.4 172 7 177 305 121 0 121 0 1.6 0 2.2 1.3 11/22/2004 03:50:00 14.1 2 19.9 8.4 16.7 1.6 20.2 12.6 0.4 0 0.4 0.4 174 7 182 305 122 0 122 0 1.6 0 2.2 1.5 11/22/2004 04:00:00 13.9 1.9 19.5 9.5 17.1 1.8 21.4 11.8 0.4 0 0.4 0.4 172 8 159 305 122 0 122 0 1.7 0.1 2.2 1.5 11/22/2004 04:10:00 15.5 2.4 20.2 8.8 17.9 2.1 22.9 12.2 0.4 0 0.4 0.4 176 6 183 305 122 0 122 0 1.6 0 2.2 1.5 11/22/2004 04:20:00 16.7 1.9 21 11.8 18.2 1.8 24 14.1 0.4 0 0.4 0.4 179 6 181 305 122 0 122 0 1.6 0 2 1.5 11/22/2004 04:30:00 16.6 2 22.6 9.5 18.5 1.7 23.3 14.5 0.4 0 0.4 0.4 178 5 187 305 123 0 122 0 1.8 0 2.5 1.5 11/22/2004 04:40:00 17.3 2.6 24.4 11.5 19.1 2.5 24.8 13.7 0.4 0 0.4 0.4 179 6 183 305 123 0 123 0 1.7 0 2.2 1.5 11/22/2004 04:50:00 18.4 2 23.7 13.3 19.6 1.8 24.8 14.5 0.4 0 0.4 0.4 180 5 179 305 124 0 124 0 1.6 0 2.2 1.3 11/22/2004 05:00:00 17.3 2.3 22.6 10.7 19 2 23.7 12.2 0.4 0 0.4 0.4 178 6 184 305 124 0 123 0 1.5 0 2.2 1.3 11/22/2004 05:10:00 19.7 1.9 24.4 13.3 20.1 1.6 24.8 14.9 0.4 0 0.4 0.4 183 5 186 305 125 0 126 0 1.4 0 2 1.3 11/22/2004 05:20:00 19.5 2.5 25.2 13.7 20 2.3 25.2 14.5 0.4 0 0.4 0.4 183 5 191 305 125 0 126 0 1.5 0 2 1.3 11/22/2004 05:30:00 19.9 2.2 26 14.5 20.4 2 26.8 15.3 0.4 0 0.4 0.4 182 5 186 305 126 0 126 0 1.4 0 2 1.3 11/22/2004 05:40:00 19.4 2 23.7 13.3 19.8 1.7 24 15.3 0.4 0 0.4 0.4 182 5 193 305 126 0 126 0 1.4 0 2 1.3 11/22/2004 05:50:00 21 1.8 24.8 15.6 21.1 1.9 25.6 14.9 0.4 0 0.4 0.4 184 4 190 305 126 0 126 0 1.4 0.1 2 1.3 11/22/2004 06:00:00 20.8 2.1 26.3 13.3 20.7 2.1 26.8 15.6 0.4 0 0.4 0.4 185 5 186 305 125 0 125 0 1.3 0.1 2 1 11/22/2004 06:10:00 21.5 2.2 26.3 15.6 21.2 2.2 26 16.4 0.4 0 0.4 0.4 186 4 192 305 125 0 125 0 1.4 0.1 2.2 1 11/22/2004 06:20:00 23.2 2 28.3 18.3 22.8 2.2 27.9 17.6 0.4 0 0.4 0.4 186 4 186 305 125 0 125 0 1.6 0.1 2.2 1.3 11/22/2004 06:30:00 23.1 2 29.4 17.2 22.5 2.3 29.1 16.8 0.4 0 0.4 0.4 187 4 192 305 125 0 125 0 1.6 0 2.2 1.5 11/22/2004 06:40:00 24.4 2.1 29.8 17.6 23.8 2 30.2 17.9 0.4 0 0.4 0.4 188 4 190 305 125 0 125 0 1.6 0 2 1.3 11/22/2004 06:50:00 23.5 1.7 28.3 19.1 23 1.9 27.5 16.4 0.4 0 0.4 0.4 188 4 189 305 125 0 125 0 1.6 0.1 2.2 1.5 11/22/2004 07:00:00 23.8 1.8 28.3 18.7 23 2.1 28.3 15.6 0.4 0 0.4 0.4 189 3 190 305 125 0 125 0 1.7 0.1 2.2 1.5 11/22/2004 07:10:00 24.2 2.1 29.1 18.7 23.5 2.3 29.4 15.6 0.4 0 0.4 0.4 189 4 191 305 124 0 124 0 1.9 0.1 2.5 1.5 11/22/2004 07:20:00 23.7 1.7 29.4 19.1 22.7 2 29.4 16.4 0.4 0 0.4 0.4 190 4 192 305 124 0 124 0 1.8 0.1 2.5 1.7 11/22/2004 07:30:00 23.9 1.8 28.7 18.7 23.1 2.1 28.3 17.6 0.4 0 0.4 0.4 189 4 192 305 123 0 123 0 1.7 0.1 2.5 1.5 11/22/2004 07:40:00 24.2 1.7 28.7 19.1 23.2 1.9 27.9 17.2 0.4 0 0.4 0.4 189 4 191 305 122 0 122 0 1.7 0.1 2.2 1.5 11/22/2004 07:50:00 24.3 2 29.4 19.5 23.3 2.1 28.7 16.8 0.4 0 0.4 0.4 190 4 194 305 122 0 121 0 1.7 0.1 2.2 1.5 11/22/2004 08:00:00 23.8 1.7 29.1 18.3 22.7 2.2 29.1 16.8 0.4 0 0.4 0.4 191 4 190 305 121 0 121 0 1.7 0.1 2.2 1.5 11/22/2004 08:10:00 23.5 1.8 28.3 18.7 22.4 2.1 28.3 16.4 0.4 0 0.4 0.4 190 4 193 305 121 0 121 0 1.7 0 2.2 1.5 11/22/2004 08:20:00 24 1.7 28.3 19.9 23.1 1.9 27.1 17.6 0.4 0 0.4 0.4 191 3 192 305 120 0 120 0 1.8 0 2.2 1.5 11/22/2004 08:30:00 23.2 1.7 27.5 19.1 22.1 1.9 26.3 17.2 0.4 0 0.4 0.4 191 4 192 305 120 0 120 0 1.7 0.1 2.2 1.5 11/22/2004 08:40:00 23.5 1.7 27.5 18.7 22.4 2.1 27.5 17.2 0.4 0 0.4 0.4 192 4 191 305 120 0 120 0 1.8 0 2.5 1.5 11/22/2004 08:50:00 22.4 2 27.9 16.8 21.2 2.3 26.8 15.6 0.4 0 0.4 0.4 192 4 193 305 120 0 120 0 1.7 0.1 2.2 1.5 11/22/2004 09:00:00 23.1 1.7 27.9 17.2 22 2 26.3 16.1 0.4 0 0.4 0.4 192 5 192 305 120 0 120 0 1.7 0.1 2.2 1.5 11/22/2004 09:10:00 22.3 1.5 25.6 17.9 21.2 1.7 24.8 15.3 0.4 0 0.4 0.4 191 5 197 305 120 0 120 0 1.7 0.1 2.2 1.5 11/22/2004 09:20:00 22.9 1.4 26.8 18.7 22.1 1.5 26 17.2 0.4 0 0.4 0.4 192 4 188 305 120 0 120 0 1.7 0 2.2 1.5 11/22/2004 09:30:00 22.4 1.7 27.1 17.9 21.3 1.8 26 16.4 0.4 0 0.4 0.4 192 4 193 305 121 0 121 0 1.7 0.1 2.2 1.5 11/22/2004 09:40:00 21.9 1.6 27.1 16.8 20.8 1.9 26.8 15.3 0.4 0 0.4 0.4 192 4 193 305 121 0 121 0 1.7 0.1 2.2 1.5 11/22/2004 09:50:00 21.8 1.6 26.8 16.4 20.7 1.9 25.6 15.3 0.4 0 0.4 0.4 193 4 196 305 121 0 121 0 1.7 0.1 2.2 1.5 11/22/2004 10:00:00 22 1.5 26 17.6 21.2 1.7 26.3 16.1 0.4 0 0.4 0.4 192 4 189 305 121 0 121 0 1.7 0.1 2.2 1.5 11/22/2004 10:10:00 21.2 1.5 24.4 15.3 20.4 1.7 24 14.1 0.4 0 0.4 0.4 191 4 193 305 121 0 121 0 1.7 0.1 2.2 1.5 11/22/2004 10:20:00 20.2 1.3 24 16.1 19.3 1.5 24 15.6 0.4 0 0.4 0.4 192 4 194 305 121 0 121 0 1.6 0 2.2 1.5 11/22/2004 10:30:00 19.2 1.3 22.6 14.5 18.2 1.5 22.6 13.3 0.4 0 0.4 0.4 192 4 198 305 121 0 121 0 1.6 0 2.2 1.5 11/22/2004 10:40:00 19.1 1.4 22.1 13.7 18.2 1.6 22.1 13 0.4 0 0.4 0.4 192 4 196 305 121 0 121 0 1.6 0 2.2 1.5 11/22/2004 10:50:00 18.8 1.3 22.9 15.6 18.1 1.6 22.6 13.3 0.4 0 0.4 0.4 191 4 194 305 121 0 121 0 1.6 0 2.2 1.5 11/22/2004 11:00:00 18.1 1.3 21 13.7 17.3 1.5 20.6 12.2 0.4 0 0.4 0.4 191 4 194 305 121 0 121 0 1.6 0 2.2 1.5 11/22/2004 11:10:00 17.6 1.1 20.2 14.5 16.7 1.3 19.5 12.6 0.4 0 0.4 0.4 191 4 191 305 121 0 121 0 1.5 0 2 1.3 11/22/2004 11:20:00 17.1 1.1 20.2 13.3 16.6 1.2 19.9 11.8 0.4 0 0.4 0.4 189 3 193 305 121 0 121 0 1.4 0 2 1.3 11/22/2004 11:30:00 17.2 1 19.9 13.7 16.9 1.2 20.2 13.7 0.4 0 0.4 0.4 187 4 183 305 122 0 122 0 1.4 0 2 1.3 11/22/2004 11:40:00 16.7 1.2 19.9 13.3 16.6 1.2 19.5 13 0.4 0 0.4 0.4 186 4 190 305 122 0 122 0 1.3 0.1 1.7 1 11/22/2004 11:50:00 16.2 1.2 19.9 13 16.3 1.3 19.9 13.3 0.4 0 0.4 0.4 185 4 190 305 122 0 122 0 1.2 0.1 1.5 1 11/22/2004 12:00:00 15.7 1 18.3 12.2 15.7 1 17.9 11.5 0.4 0 0.4 0.4 185 3 186 305 123 0 123 0 1.1 0.1 1.5 1 11/22/2004 12:10:00 14.9 1.3 18.3 11.5 15.5 1.2 18.7 12.6 0.4 0 0.4 0.4 183 4 185 305 124 0 124 0 1.2 0.1 1.5 1 11/22/2004 12:20:00 14.5 1.4 19.1 11.1 15.1 1.3 18.7 10.7 0.4 0 0.4 0.4 183 4 188 305 124 0 124 0 1.2 0.1 1.7 1 11/22/2004 12:30:00 15 1.5 18.7 9.9 15.2 1.3 18.7 11.5 0.4 0 0.4 0.4 185 4 189 305 125 0 125 0 1.2 0.1 1.7 1 11/22/2004 12:40:00 13.8 1 16.8 11.1 13.4 1 16.4 10.7 0.4 0 0.4 0.4 188 4 188 305 125 0 125 0 1 0 1.5 1 11/22/2004 12:50:00 13.7 1 16.8 11.1 13.4 1.1 16.4 9.5 0.4 0 0.4 0.4 188 4 191 305 126 0 126 0 1.1 0.1 1.5 1 11/22/2004 13:00:00 14 1.2 17.6 11.5 13.8 1.2 17.6 10.7 0.4 0 0.4 0.4 188 4 196 305 126 0 126 0 1.2 0.1 1.7 1 11/22/2004 13:10:00 13.3 0.9 16.8 11.5 12.9 1.1 16.4 10.3 0.4 0 0.4 0.4 189 4 193 305 126 0 126 0 1.2 0.1 1.7 1 11/22/2004 13:20:00 12.6 1 14.9 10.3 12.5 1 14.9 9.5 0.4 0 0.4 0.4 186 4 180 305 127 0 127 0 1.2 0.1 1.7 1 11/22/2004 13:30:00 12.7 1 15.3 9.5 12.5 0.9 14.5 9.5 0.4 0 0.4 0.4 187 4 188 305 128 0 127 0 1.2 0.1 1.7 1 11/22/2004 13:40:00 12.7 0.9 15.3 10.7 12.4 1 14.9 9.5 0.4 0 0.4 0.4 188 4 188 305 128 0 128 0 1.2 0.1 1.7 1 11/22/2004 13:50:00 13 0.9 15.3 9.9 12.8 1 15.3 9.9 0.4 0 0.4 0.4 187 4 192 305 129 0 129 0 1.2 0.1 1.7 1 11/22/2004 14:00:00 13.3 0.9 15.6 10.7 13 1 15.6 9.9 0.4 0 0.4 0.4 188 3 188 305 129 0 129 0 1.2 0.1 1.7 1 11/22/2004 14:10:00 12.9 0.8 16.1 10.7 12.5 0.9 14.9 9.9 0.4 0 0.4 0.4 188 4 190 305 130 0 130 0 1.3 0 2 1 11/22/2004 14:20:00 11.7 1 14.9 9.1 11.8 0.9 14.1 8.8 0.4 0 0.4 0.4 186 4 186 305 130 0 130 0 1.3 0 2 1.3 11/22/2004 14:30:00 10.8 1 13 7.6 11.7 0.9 14.1 9.5 0.4 0 0.4 0.4 183 4 189 305 131 0 131 0 1.3 0.1 1.7 1 11/22/2004 14:40:00 11.7 1.1 14.9 6.8 12.3 1.1 15.3 9.1 0.4 0 0.4 0.4 183 4 185 305 131 0 131 0 1.4 0 2 1.3 11/22/2004 14:50:00 11.4 0.9 13.7 8.8 11.5 0.8 13.7 9.1 0.4 0 0.4 0.4 185 4 187 305 131 0 131 0 1.4 0 2 1.3 11/22/2004 15:00:00 11.1 0.8 13 9.1 11.2 0.8 13 9.1 0.4 0 0.4 0.4 186 3 184 305 131 0 131 0 1.5 0 2 1.3 11/22/2004 15:10:00 11.3 1 13.7 8.4 11.3 0.9 13.7 8.8 0.4 0 0.4 0.4 186 4 186 305 131 0 131 0 1.4 0 2 1.3 11/22/2004 15:20:00 10.7 0.8 12.6 8 10.5 0.8 12.2 7.6 0.4 0 0.4 0.4 188 3 185 305 131 0 131 0 1.3 0.1 2 1.3 11/22/2004 15:30:00 11 0.8 13 9.1 10.8 0.9 13 8 0.4 0 0.4 0.4 187 3 183 305 130 0 130 0 1.3 0.1 1.7 1 11/22/2004 15:40:00 10.9 0.7 12.6 7.6 10.5 0.8 12.2 8 0.4 0 0.4 0.4 188 3 193 305 130 0 130 0 1.2 0.1 1.7 1 11/22/2004 15:50:00 10.8 0.7 12.6 8.4 10.6 0.7 12.2 8 0.4 0 0.4 0.4 187 3 189 305 129 0 130 0 1.2 0.1 1.7 1 11/22/2004 16:00:00 9.4 1.1 12.2 5.7 9.9 0.8 12.2 7.6 0.4 0 0.4 0.4 184 4 193 305 129 0 129 0 1.2 0.1 2 1 11/22/2004 16:10:00 9 0.7 10.7 7.2 10 0.6 11.5 8 0.4 0 0.4 0.4 182 3 181 305 130 0 130 0 1.6 0.1 2.2 1.3 11/22/2004 16:20:00 7.9 1.1 11.5 4.6 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 180 4 181 305 130 0 130 0 1.7 0.1 2.5 1.5 11/22/2004 16:30:00 8.3 1 10.3 4.9 9.6 0.7 11.1 7.2 0.4 0 0.4 0.4 181 4 186 305 130 0 130 0 2 0 2.5 2 11/22/2004 16:40:00 8.4 1 10.3 4.9 9.5 0.8 11.1 6.8 0.4 0 0.4 0.4 183 4 188 305 122 4 130 0 2.1 0 2.7 2 11/22/2004 16:50:00 9.2 0.5 10.7 7.2 9.6 0.6 11.1 8 0.4 0 0.4 0.4 186 3 186 305 119 0 119 0 2 0.1 2.7 1.7 11/22/2004 17:00:00 7.6 1.3 9.5 4.2 8.4 0.8 9.9 6.1 0.4 0 0.4 0.4 182 5 192 305 118 0 119 0 1.9 0.1 2.5 1.5 11/22/2004 17:10:00 7.5 1.2 10.3 3.8 8.5 1 11.5 6.5 0.4 0 0.4 0.4 166 13 183 305 119 0 119 0 2.1 0.2 2.9 1.5 11/22/2004 17:20:00 6.6 1 8.8 3.8 6.9 0.7 8.8 5.3 0.4 0 0.4 0.4 158 6 142 305 119 0 119 0 1.6 0 2.2 1.3 11/22/2004 17:30:00 6.3 1 9.1 4.2 8.5 1 10.7 5.7 0.4 0 0.4 0.4 164 5 165 305 119 0 119 0 1.6 0.1 2.2 1.3 11/22/2004 17:40:00 7.7 1.5 11.8 4.9 10.6 1 13.3 7.6 0.4 0 0.4 0.4 174 6 177 305 121 1 122 0 2.3 0.4 3.2 1.7 11/22/2004 17:50:00 6.4 1.1 9.9 3.8 8.7 1.2 11.5 5.7 0.4 0 0.4 0.4 171 7 183 305 123 1 122 0 2.5 0.1 3.2 2.2 11/22/2004 18:00:00 8.4 1.1 9.9 4.6 8.3 0.8 9.9 5.7 0.4 0 0.4 0.4 155 5 159 305 123 0 123 0 1.6 0.1 2.2 1.5 11/22/2004 18:10:00 8.7 0.8 10.3 6.5 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 153 5 152 305 124 0 124 0 1.3 0.1 2 1 11/22/2004 18:20:00 9 0.7 10.3 6.8 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 153 4 147 305 124 0 124 0 1.3 0 1.7 1 11/22/2004 18:30:00 8.2 1 10.7 4.6 8 0.8 9.9 5.7 0.4 0 0.4 0.4 154 6 146 305 125 0 125 0 1.2 0.1 1.5 1 11/22/2004 18:40:00 8.1 1 10.3 4.9 7.8 0.8 9.9 5.7 0.4 0 0.4 0.4 155 5 156 305 125 0 125 0 1.1 0 1.5 1 11/22/2004 18:50:00 8 0.9 10.3 4.9 7.7 0.8 9.9 5.7 0.4 0 0.4 0.4 152 6 157 305 125 0 125 0 1 0 1.5 0.6 11/22/2004 19:00:00 7.6 0.8 9.5 5.7 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 146 6 146 305 125 0 125 0 0.6 0.1 1.3 0.3 11/22/2004 19:10:00 7.9 0.7 9.9 6.1 7.4 0.7 9.5 5.7 0.4 0 0.4 0.4 149 5 152 305 125 0 125 0 0.4 0 1 0.1 11/22/2004 19:20:00 8.9 0.8 11.1 6.8 8.4 0.8 10.7 6.5 0.4 0 0.4 0.4 150 5 153 305 125 0 125 0 0.4 0 1 0.1 11/22/2004 19:30:00 8 1.1 10.3 5.3 7.6 1 10.3 4.9 0.4 0 0.4 0.4 147 7 150 305 125 0 125 0 0.5 0 1 0.3 11/22/2004 19:40:00 5.5 1 8.4 3.4 5.4 0.9 8.4 3.8 0.4 0 0.4 0.4 129 12 151 305 125 0 126 0 0.3 0 0.8 0.1 11/22/2004 19:50:00 4.7 0.7 6.1 3 4.6 0.6 6.5 3.4 0.4 0 0.4 0.4 125 10 142 305 125 0 125 0 0.3 0.1 0.8 0.1 11/22/2004 20:00:00 5.3 0.5 6.8 3.8 5.2 0.5 6.5 4.2 0.4 0 0.4 0.4 142 5 150 305 125 0 125 0 0 0 0.6 -0.1 11/22/2004 20:10:00 7.3 1 9.9 4.6 7.3 1 9.5 4.6 0.4 0 0.4 0.4 133 6 130 305 125 0 125 0 0 0 0.3 -0.1 11/22/2004 20:20:00 7.9 0.8 10.3 6.1 7.9 0.8 10.7 6.1 0.4 0 0.4 0.4 129 8 111 305 125 0 125 0 0.1 0 0.6 0.1 11/22/2004 20:30:00 8.1 1.3 11.1 4.6 8 1.2 10.7 4.6 0.4 0 0.4 0.4 121 11 120 305 125 0 125 0 0.3 0 1 0.1 11/22/2004 20:40:00 6 1.4 9.5 3 5.8 1.3 9.5 3 0.4 0 0.4 0.4 112 17 124 305 125 0 125 0 0.3 0 0.6 0.1 11/22/2004 20:50:00 7.5 1.5 11.1 3.8 7.2 1.5 10.7 3.8 0.4 0 0.4 0.4 122 12 130 305 125 0 125 0 0.3 0 0.8 0.1 11/22/2004 21:00:00 7.6 1.7 11.1 3.8 7.6 1.5 11.1 3.8 0.4 0 0.4 0.4 115 11 113 305 124 0 124 0 0.3 0 1 0.3 11/22/2004 21:10:00 7.9 1 10.3 4.9 7.7 1.1 10.3 4.2 0.4 0 0.4 0.4 105 15 121 305 124 0 124 0 0.3 0 0.8 0.1 11/22/2004 21:20:00 3.9 1.3 8.4 0.7 4 1.2 8 1.5 0.4 0 0.4 0.4 84 24 84 305 124 0 125 0 0.3 0 0.8 0.1 11/22/2004 21:30:00 4.7 1.7 10.3 0.4 4.7 1.6 10.3 0.4 0.4 0 0.4 0.4 75 23 54 305 125 0 125 0 0.4 0 1 0.3 11/22/2004 21:40:00 4.5 1.5 7.6 0.7 4.4 1.5 8.4 1.1 0.4 0 0.4 0.4 93 23 69 305 125 0 125 0 0.5 0 1 0.3 11/22/2004 21:50:00 6.5 2.3 11.8 2.3 6.4 2.2 11.5 1.5 0.4 0 0.4 0.4 80 26 72 305 125 0 125 0 0.6 0.1 1.3 0.3 11/22/2004 22:00:00 5.5 1.5 11.1 2.3 5.6 1.5 11.1 2.6 0.4 0 0.4 0.4 89 26 78 305 125 0 125 0 0.6 0 1 0.6 11/22/2004 22:10:00 5.6 1.4 9.5 2.6 5.7 1.3 8.8 3 0.4 0 0.4 0.4 102 16 105 305 125 0 125 0 0.4 0.1 1 0.1 11/22/2004 22:20:00 7.1 2 12.2 2.3 7.1 2 11.8 2.6 0.4 0 0.4 0.4 77 17 84 305 125 0 125 0 0.3 0 0.8 0.1 11/22/2004 22:30:00 8.2 1.3 11.1 4.2 8.1 1.2 10.7 4.2 0.4 0 0.4 0.4 86 16 88 305 125 0 125 0 0.2 0.1 0.6 0.1 11/22/2004 22:40:00 7.6 0.9 11.1 5.3 7.4 0.9 11.5 5.3 0.4 0 0.4 0.4 82 8 80 305 125 0 125 0 0 0 0.6 -0.1 11/22/2004 22:50:00 8.4 1 12.2 4.9 8.2 1 11.1 4.9 0.4 0 0.4 0.4 88 8 87 305 126 0 126 0 0 0 0.6 0.1 11/22/2004 23:00:00 8.4 1 10.7 5.7 8.1 1 10.7 5.7 0.4 0 0.4 0.4 84 8 88 305 126 0 126 0 0 0 0.6 -0.1 11/22/2004 23:10:00 7.8 0.8 9.9 5.3 7.5 0.8 9.5 4.9 0.4 0 0.4 0.4 77 6 78 305 126 0 126 0 0 0 0.3 -0.1 11/22/2004 23:20:00 7.8 0.6 9.5 6.1 7.6 0.6 9.5 6.1 0.4 0 0.4 0.4 72 6 75 305 126 0 126 0 0 0 0.6 -0.1 11/22/2004 23:30:00 7.8 0.6 9.5 6.5 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 69 5 77 305 126 0 126 0 0 0 0.6 -0.1 11/22/2004 23:40:00 6.8 0.8 8.8 5.3 6.6 0.8 8.8 4.9 0.4 0 0.4 0.4 61 5 62 305 126 0 126 0 0 0 0.6 0.1 11/22/2004 23:50:00 6.5 0.7 8.4 4.9 6.3 0.7 8.4 4.9 0.4 0 0.4 0.4 62 4 66 305 126 0 126 0 0 0 0.3 -0.1 11/23/2004 00:00:00 7.2 0.5 8.8 5.3 7 0.5 8.8 5.7 0.4 0 0.4 0.4 62 4 65 305 126 1 126 0 0.1 0.1 0.6 0.1 11/23/2004 00:10:00 8.2 0.5 9.5 6.1 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 64 3 67 305 126 0 126 0 0.1 0.1 0.6 0.1 11/23/2004 00:20:00 8.8 1 11.5 6.5 8.5 1 10.7 6.1 0.4 0 0.4 0.4 64 6 73 305 126 0 126 0 0.2 0 0.8 0.1 11/23/2004 00:30:00 10.2 1 13 6.8 9.9 1 12.2 6.8 0.4 0 0.4 0.4 71 6 75 305 126 0 126 0 0.4 0 0.8 0.3 11/23/2004 00:40:00 11.8 0.9 14.1 9.1 11.5 0.8 13.7 8.4 0.4 0 0.4 0.4 68 4 68 305 126 0 126 0 0.4 0 1 0.1 11/23/2004 00:50:00 10.7 0.9 12.6 7.6 10.3 0.9 12.6 8 0.4 0 0.4 0.4 64 4 68 305 125 0 126 0 0.2 0.1 0.6 0.1 11/23/2004 01:00:00 9.9 0.6 11.5 8.4 9.5 0.7 11.1 8 0.4 0 0.4 0.4 64 4 66 305 125 0 125 0 0.1 0.1 0.6 0.1 11/23/2004 01:10:00 10 0.6 11.5 8.4 9.6 0.6 11.5 8 0.4 0 0.4 0.4 63 4 57 305 125 0 124 0 0.1 0.1 0.6 0.1 11/23/2004 01:20:00 11.5 0.8 13.3 8.8 11.1 0.9 13 8.4 0.4 0 0.4 0.4 67 3 69 305 124 0 125 0 0.2 0.1 0.6 0.1 11/23/2004 01:30:00 11.7 0.5 13.3 10.3 11.4 0.6 13 9.5 0.4 0 0.4 0.4 67 3 69 305 124 0 125 0 0.3 0 0.8 0.1 11/23/2004 01:40:00 11.8 0.7 14.1 9.9 11.6 0.7 13.7 9.5 0.4 0 0.4 0.4 67 3 66 305 124 0 124 0 0.4 0 0.8 0.3 11/23/2004 01:50:00 10.2 0.7 12.2 8.4 9.8 0.7 11.5 8 0.4 0 0.4 0.4 65 4 69 305 124 0 124 0 0.2 0 0.6 0.1 11/23/2004 02:00:00 10 0.7 11.5 8 9.6 0.7 11.5 7.6 0.4 0 0.4 0.4 62 4 61 305 123 0 124 0 0 0.1 0.6 0.1 11/23/2004 02:10:00 10.5 0.7 12.2 8.8 10.1 0.7 11.8 8 0.4 0 0.4 0.4 65 4 68 305 123 0 123 0 0.1 0.1 0.6 0.1 11/23/2004 02:20:00 10.4 0.8 12.2 8.4 10 0.9 11.8 7.6 0.4 0 0.4 0.4 62 4 64 305 123 0 124 0 0.2 0 0.6 0.1 11/23/2004 02:30:00 10.3 0.8 12.6 8.4 9.9 0.8 12.6 8 0.4 0 0.4 0.4 64 4 61 305 122 0 122 0 0.1 0 0.6 0.1 11/23/2004 02:40:00 11.7 1.2 14.1 8.8 11.3 1.2 13.7 8.8 0.4 0 0.4 0.4 66 4 73 305 123 0 123 0 0.1 0.1 0.6 0.1 11/23/2004 02:50:00 12.5 0.7 14.5 11.1 12.2 0.8 14.1 10.3 0.4 0 0.4 0.4 70 4 68 305 123 0 123 0 0.1 0 0.6 0.1 11/23/2004 03:00:00 11.7 0.6 13.3 9.5 11.3 0.7 13 9.5 0.4 0 0.4 0.4 67 3 69 305 123 0 123 0 0.1 0 0.1 0.1 11/23/2004 03:10:00 10.6 0.7 12.2 8 10.3 0.7 12.2 8.4 0.4 0 0.4 0.4 64 3 62 305 123 0 123 0 0 0 0.6 0.1 11/23/2004 03:20:00 9.8 0.6 11.1 8 9.4 0.7 11.1 7.6 0.4 0 0.4 0.4 57 4 61 305 123 0 123 0 0 0 0.6 0.1 11/23/2004 03:30:00 9.6 0.6 11.1 8 9.3 0.7 11.1 7.6 0.4 0 0.4 0.4 55 4 54 305 123 0 123 0 0 0 0.6 0.1 11/23/2004 03:40:00 10.3 0.9 12.6 8.4 10.1 0.9 12.6 7.6 0.4 0 0.4 0.4 56 4 56 305 123 0 123 0 0 0 0.1 0.1 11/23/2004 03:50:00 11.4 0.7 13 9.1 11.1 0.8 13 8.8 0.4 0 0.4 0.4 51 4 53 305 123 1 123 0 0.2 0 0.3 0.1 11/23/2004 04:00:00 11.2 0.7 13 9.1 10.9 0.8 13 9.1 0.4 0 0.4 0.4 53 3 54 305 124 0 124 0 0.2 0 0.6 0.1 11/23/2004 04:10:00 11 0.6 12.6 9.1 10.7 0.7 12.6 8.4 0.4 0 0.4 0.4 57 4 59 305 124 0 124 0 0.1 0 0.6 0.1 11/23/2004 04:20:00 10.8 0.7 13.3 9.1 10.5 0.7 13 8.8 0.4 0 0.4 0.4 60 4 61 305 124 0 125 0 0.1 0.1 0.6 0.1 11/23/2004 04:30:00 10.7 0.9 13 8.8 10.4 0.9 12.6 8.8 0.4 0 0.4 0.4 60 3 65 305 125 0 124 0 0.1 0.1 0.6 0.1 11/23/2004 04:40:00 10.5 0.7 12.2 8.8 10.2 0.8 11.8 7.6 0.4 0 0.4 0.4 65 4 74 305 125 0 125 0 0.1 0.1 0.6 0.1 11/23/2004 04:50:00 10.7 1 12.6 8 10.4 0.9 12.2 8 0.4 0 0.4 0.4 65 4 65 305 125 0 125 0 0.1 0.1 0.6 0.1 11/23/2004 05:00:00 10.9 1 13 8.4 10.5 1 13 7.6 0.4 0 0.4 0.4 62 4 64 305 125 0 125 0 0.1 0 0.6 0.1 11/23/2004 05:10:00 11.6 1.2 14.1 9.1 11.2 1.2 14.1 8.8 0.4 0 0.4 0.4 64 4 64 305 124 0 124 0 0.1 0 0.3 0.1 11/23/2004 05:20:00 12.8 0.7 14.5 11.1 12.5 0.8 14.5 10.3 0.4 0 0.4 0.4 65 3 66 305 124 0 124 0 0.2 0 0.3 0.1 11/23/2004 05:30:00 11.9 0.8 13.7 9.9 11.5 0.9 13.3 9.1 0.4 0 0.4 0.4 63 3 62 305 124 0 124 0 0.2 0 0.3 0.1 11/23/2004 05:40:00 12.2 0.9 14.5 9.1 11.9 0.9 14.1 8.8 0.4 0 0.4 0.4 62 3 61 305 124 0 124 0 0.2 0 0.3 0.1 11/23/2004 05:50:00 11.2 1 13.3 9.1 10.9 1 13.3 8.4 0.4 0 0.4 0.4 60 4 64 305 123 0 124 0 0.3 0 0.3 0.1 11/23/2004 06:00:00 10.5 0.8 12.6 8.8 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 62 4 64 305 123 0 124 0 0.3 0 0.8 0.3 11/23/2004 06:10:00 10.1 0.8 12.6 8 9.8 0.8 12.2 8.4 0.4 0 0.4 0.4 63 4 59 305 123 0 123 0 0.3 0 0.6 0.1 11/23/2004 06:20:00 10.5 0.6 12.2 9.1 10.2 0.7 11.5 8 0.4 0 0.4 0.4 64 4 65 305 123 0 123 0 0.4 0 0.8 0.3 11/23/2004 06:30:00 9.9 0.9 12.2 7.6 9.5 0.9 11.8 7.2 0.4 0 0.4 0.4 63 5 57 305 122 0 122 0 0.4 0 0.6 0.3 11/23/2004 06:40:00 10.2 1.5 14.1 7.2 9.8 1.5 14.1 6.8 0.4 0 0.4 0.4 65 5 68 305 122 0 122 0 0.4 0 0.8 0.3 11/23/2004 06:50:00 12.7 0.9 14.9 10.7 12.2 1 14.9 10.3 0.4 0 0.4 0.4 65 4 68 305 121 0 121 0 0.5 0 0.8 0.3 11/23/2004 07:00:00 11.6 0.9 13.3 8.8 11.1 0.8 13 8.8 0.4 0 0.4 0.4 66 5 69 305 121 0 120 0 0.5 0 1 0.6 11/23/2004 07:10:00 10.9 1.3 14.1 7.6 10.4 1.3 13.3 7.2 0.4 0 0.4 0.4 63 5 63 305 121 0 121 0 0.5 0 0.8 0.3 11/23/2004 07:20:00 11.2 1 13.7 8.8 10.8 1.1 13 8.4 0.4 0 0.4 0.4 62 5 59 305 121 0 120 0 0.5 0 0.8 0.3 11/23/2004 07:30:00 11.6 1.1 14.1 8.4 11.2 1 13.7 8.4 0.4 0 0.4 0.4 63 5 67 305 120 0 120 0 0.5 0 0.8 0.3 11/23/2004 07:40:00 13.1 1.1 15.6 9.9 12.7 1.2 15.6 9.5 0.4 0 0.4 0.4 66 5 68 305 120 0 120 0 0.6 0.1 1 0.6 11/23/2004 07:50:00 13.8 1 16.4 11.5 13.6 1 16.1 10.7 0.4 0 0.4 0.4 66 4 68 305 120 0 120 0 0.7 0 1 0.6 11/23/2004 08:00:00 12.4 1.1 15.3 9.9 12 1.1 14.9 8.8 0.4 0 0.4 0.4 63 5 66 305 119 0 120 0 0.6 0.1 1 0.6 11/23/2004 08:10:00 12.6 0.9 14.9 9.9 12.3 0.9 14.5 9.9 0.4 0 0.4 0.4 58 5 54 305 119 0 119 0 0.6 0.1 1 0.6 11/23/2004 08:20:00 13.1 1 15.3 11.1 13 1 15.6 10.7 0.4 0 0.4 0.4 59 4 62 305 119 0 119 0 0.7 0 1.3 0.6 11/23/2004 08:30:00 14 1 17.2 11.5 13.8 1.1 16.8 11.1 0.4 0 0.4 0.4 63 4 62 305 119 0 120 0 0.9 0 1.5 0.8 11/23/2004 08:40:00 14.4 0.9 16.4 12.2 14.2 0.8 16.1 11.8 0.4 0 0.4 0.4 65 3 58 305 119 0 119 0 1 0 1.5 0.8 11/23/2004 08:50:00 15 1 17.6 12.2 14.8 1 17.2 12.2 0.4 0 0.4 0.4 66 3 63 305 119 1 120 0 1.1 0 1.5 1 11/23/2004 09:00:00 13.4 1.2 16.1 10.3 13.2 1.3 15.6 9.9 0.4 0 0.4 0.4 64 4 63 305 121 0 118 0 1.1 0 1.5 1 11/23/2004 09:10:00 13.2 1 15.3 10.7 12.9 1.1 15.6 9.9 0.4 0 0.4 0.4 66 4 66 305 120 0 120 0 1.2 0.1 1.3 1 11/23/2004 09:20:00 15.2 1.1 17.9 12.6 14.8 1.2 17.9 12.2 0.4 0 0.4 0.4 68 4 68 305 119 1 119 0 1.2 0 1.7 1 11/23/2004 09:30:00 15 1.2 18.3 11.8 14.6 1.3 17.9 11.1 0.4 0 0.4 0.4 67 4 66 305 120 0 120 0 1.2 0 1.5 1 11/23/2004 09:40:00 14.9 1 17.2 11.8 14.6 1 17.2 11.8 0.4 0 0.4 0.4 66 4 67 305 120 0 120 0 1.2 0 1.5 1 11/23/2004 09:50:00 15.1 1.3 18.7 12.2 14.7 1.3 17.9 11.8 0.4 0 0.4 0.4 65 5 62 305 120 0 120 0 1.2 0 1.5 1 11/23/2004 10:00:00 13.9 1.2 16.8 11.1 13.5 1.3 16.8 10.3 0.4 0 0.4 0.4 63 5 64 305 120 0 120 0 1.2 0.1 1.5 1 11/23/2004 10:10:00 13.2 1 16.1 10.7 12.7 1 15.3 10.3 0.4 0 0.4 0.4 61 4 60 305 119 0 119 0 1 0 1.5 1 11/23/2004 10:20:00 12.4 1.2 15.3 9.9 12 1.2 15.3 8.8 0.4 0 0.4 0.4 60 4 62 305 118 0 118 0 1 0 1.5 0.8 11/23/2004 10:30:00 12.4 0.9 14.9 9.9 12 1 14.5 8.8 0.4 0 0.4 0.4 62 5 65 305 118 1 117 0 1 0.1 1.5 1 11/23/2004 10:40:00 12.4 1.1 14.9 9.5 12.1 1.2 15.3 8.8 0.4 0 0.4 0.4 64 5 66 305 120 0 120 0 1.1 0.1 1.5 1 11/23/2004 10:50:00 14.9 1.3 18.3 11.1 14.4 1.4 18.7 10.7 0.4 0 0.4 0.4 67 4 68 305 122 2 123 0 1.2 0.1 1.7 1 11/23/2004 11:00:00 16.5 1.2 20.2 13.7 16.1 1.3 20.2 12.6 0.4 0 0.4 0.4 68 4 67 305 122 0 122 0 1.3 0 1.7 1.3 11/23/2004 11:10:00 16.3 1.1 19.1 13 16 1.2 18.7 12.6 0.4 0 0.4 0.4 68 4 73 305 121 0 121 0 1.3 0 1.7 1.3 11/23/2004 11:20:00 15.4 1.1 18.7 11.8 15 1.1 17.9 11.8 0.4 0 0.4 0.4 67 4 66 305 116 2 120 0 1.2 0.1 1.7 1 11/23/2004 11:30:00 15.9 1 17.9 13.7 15.6 1.1 18.7 13 0.4 0 0.4 0.4 69 5 67 305 113 1 112 0 1.2 0.1 1.5 1 11/23/2004 11:40:00 15.7 1.1 18.7 13 15.4 1.2 18.7 12.6 0.4 0 0.4 0.4 71 6 75 305 108 1 108 0 1.1 0 1.5 1 11/23/2004 11:50:00 15 1 17.2 12.2 14.9 1.1 17.9 12.2 0.4 0 0.4 0.4 70 5 75 305 104 3 108 0 0.7 0.1 1.3 0.6 11/23/2004 12:00:00 14.8 1 17.6 11.8 14.6 1.2 17.9 10.7 0.4 0 0.4 0.4 67 4 74 305 100 0 100 0 0.5 0 1 0.6 11/23/2004 12:10:00 13.6 1 16.1 11.5 13.4 1 16.4 10.7 0.4 0 0.4 0.4 66 4 66 305 101 0 101 0 0.4 0 1 0.3 11/23/2004 12:20:00 12.8 0.9 15.3 10.3 12.8 1 15.6 9.9 0.4 0 0.4 0.4 67 5 67 305 106 2 108 0 0.4 0 1 0.3 11/23/2004 12:30:00 12.5 1.3 16.1 9.1 12.2 1.4 15.6 8 0.4 0 0.4 0.4 72 8 67 305 109 1 109 0 0.5 0 1 0.3 11/23/2004 12:40:00 11.9 1.8 16.8 7.2 11.7 1.9 16.8 6.8 0.4 0 0.4 0.4 75 14 87 305 108 1 108 0 0.7 0 1 0.6 11/23/2004 12:50:00 11.9 2.4 17.9 5.7 11.7 2.6 19.1 5.7 0.4 0 0.4 0.4 73 15 71 305 106 1 106 0 0.8 0 1.3 0.6 11/23/2004 13:00:00 11.3 1.9 16.8 6.5 11.2 2.1 17.2 6.1 0.4 0 0.4 0.4 72 12 65 305 103 0 103 0 0.9 0 1.3 0.8 11/23/2004 13:10:00 11.6 1.7 16.1 6.5 11.5 1.7 16.4 6.1 0.4 0 0.4 0.4 74 10 78 305 103 1 103 0 0.8 0 1.3 0.6 11/23/2004 13:20:00 11.6 1.5 14.9 7.2 11.4 1.5 15.6 6.8 0.4 0 0.4 0.4 75 9 74 305 102 0 103 0 0.7 0 1.3 0.6 11/23/2004 13:30:00 11.3 2 16.8 5.3 11.2 2.2 16.1 4.9 0.4 0 0.4 0.4 73 13 78 305 102 0 103 0 0.7 0 1.3 0.6 11/23/2004 13:40:00 11.2 1.5 15.6 7.6 11 1.5 15.3 7.6 0.4 0 0.4 0.4 70 9 76 305 102 0 102 0 0.9 0 1.3 0.6 11/23/2004 13:50:00 10.2 1.6 14.5 5.3 9.9 1.6 14.5 5.7 0.4 0 0.4 0.4 71 13 62 305 102 0 102 0 0.9 0 1.5 0.8 11/23/2004 14:00:00 11.6 1.5 15.6 7.6 11.3 1.7 17.6 6.1 0.4 0 0.4 0.4 74 9 72 305 102 0 102 0 1 0 1.5 1 11/23/2004 14:10:00 11.9 1.3 15.3 8.4 11.7 1.4 15.6 8 0.4 0 0.4 0.4 75 8 80 305 102 0 103 0 1 0 1.5 1 11/23/2004 14:20:00 11.7 1.9 16.8 5.7 11.5 2.1 16.4 6.1 0.4 0 0.4 0.4 76 12 65 305 103 1 103 0 1 0 1.5 1 11/23/2004 14:30:00 11.8 1.6 16.4 8 11.7 1.6 16.1 7.6 0.4 0 0.4 0.4 74 9 90 305 103 0 103 0 1 0 1.5 1 11/23/2004 14:40:00 11.4 1.7 17.2 7.2 11.1 1.8 17.9 6.5 0.4 0 0.4 0.4 77 11 72 305 99 2 98 0 1 0 1.5 1 11/23/2004 14:50:00 10.8 2 16.8 5.7 10.6 2.2 16.8 5.7 0.4 0 0.4 0.4 75 14 81 305 98 0 99 0 1 0 1.3 1 11/23/2004 15:00:00 10.3 1.9 15.6 5.7 10.1 1.9 14.5 4.9 0.4 0 0.4 0.4 75 15 81 305 98 0 97 0 1 0 1.5 1 11/23/2004 15:10:00 10.2 2.2 15.6 5.7 9.8 2.2 17.9 5.7 0.4 0 0.4 0.4 87 20 70 305 98 0 97 0 1 0 1.5 0.8 11/23/2004 15:20:00 8.3 2 14.1 3.4 8 2.1 14.1 3.8 0.4 0 0.4 0.4 95 22 55 305 98 1 98 0 1 0 1.5 1 11/23/2004 15:30:00 9.2 2.1 15.6 4.9 9.1 2.3 15.6 4.6 0.4 0 0.4 0.4 77 21 54 305 97 2 95 0 1.3 0 1.7 1 11/23/2004 15:40:00 10 2.1 15.6 4.9 9.9 2.2 15.6 4.9 0.4 0 0.4 0.4 70 16 71 305 108 1 107 0 1.1 0 1.5 1 11/23/2004 15:50:00 9.6 1.7 14.1 4.6 9.5 1.7 14.5 4.2 0.4 0 0.4 0.4 70 11 99 305 107 2 108 0 1 0 1.5 0.8 11/23/2004 16:00:00 9.6 1.9 16.1 4.2 9.1 2.1 14.9 2.6 0.4 0 0.4 0.4 77 16 68 305 113 2 112 0 0.9 0 1.5 0.8 11/23/2004 16:10:00 9.6 2.1 16.1 4.2 9.5 2 16.1 3.8 0.4 0 0.4 0.4 71 14 61 305 117 0 117 0 0.8 0.1 1.5 0.6 11/23/2004 16:20:00 9.4 1.1 13 6.8 9.3 1.1 13.3 6.1 0.4 0 0.4 0.4 71 10 53 305 122 3 117 0 0.7 0 1.3 0.6 11/23/2004 16:30:00 7.7 1.9 12.6 3 7.5 2 11.8 3 0.4 0 0.4 0.4 77 15 93 305 125 2 124 0 0.8 0 1.3 0.6 11/23/2004 16:40:00 7.4 1.7 11.8 3.4 7.1 1.7 11.1 3 0.4 0 0.4 0.4 90 22 46 305 126 1 127 0 1 0 1.5 0.8 11/23/2004 16:50:00 8.9 2 13 2.6 8.4 2 13.3 2.6 0.4 0 0.4 0.4 83 20 76 305 127 0 127 0 1 0 1.5 1 11/23/2004 17:00:00 8.8 1.7 14.1 4.9 8.5 1.7 13.3 4.6 0.4 0 0.4 0.4 76 14 77 305 127 0 127 0 1 0 1.5 1 11/23/2004 17:10:00 8.6 1.7 14.1 4.6 8.2 1.7 13.7 4.9 0.4 0 0.4 0.4 84 15 70 305 125 0 125 0 1 0 1.5 1 11/23/2004 17:20:00 9.2 1.2 13.3 6.1 9 1.2 12.2 6.5 0.4 0 0.4 0.4 81 9 86 305 127 1 127 0 1 0 1.5 1 11/23/2004 17:30:00 9.1 1.2 12.2 5.3 8.8 1.2 12.6 5.3 0.4 0 0.4 0.4 83 10 78 305 127 0 128 0 1.1 0 1.5 1 11/23/2004 17:40:00 9.1 1.3 13 6.1 8.8 1.3 12.6 5.3 0.4 0 0.4 0.4 84 9 85 305 126 0 126 0 1.2 0.1 1.5 1 11/23/2004 17:50:00 9.6 1.2 13 6.5 9.3 1.2 12.6 6.5 0.4 0 0.4 0.4 86 9 87 305 125 0 126 0 1.2 0 1.5 1 11/23/2004 18:00:00 10.1 1.3 13.3 6.5 9.7 1.2 12.6 7.2 0.4 0 0.4 0.4 87 9 88 305 125 0 126 0 1.2 0.1 1.5 1 11/23/2004 18:10:00 9.6 1.3 13 6.1 9.2 1.4 13.7 5.7 0.4 0 0.4 0.4 90 12 64 305 125 0 125 0 1.1 0 1.5 1 11/23/2004 18:20:00 9.5 1.3 13.3 6.5 9.2 1.3 13 5.7 0.4 0 0.4 0.4 85 9 92 305 124 0 125 0 1.1 0 1.3 1 11/23/2004 18:30:00 9.5 1.1 13 6.1 9 1.1 13 5.7 0.4 0 0.4 0.4 84 8 82 305 125 0 125 0 1 0 1.5 1 11/23/2004 18:40:00 9.6 1.4 13.7 5.7 9.4 1.4 13 5.3 0.4 0 0.4 0.4 83 9 97 305 125 0 125 0 1 0 1 1 11/23/2004 18:50:00 9.6 1.4 12.6 5.3 9.2 1.3 12.2 5.3 0.4 0 0.4 0.4 85 9 48 305 125 0 125 0 1 0 1.5 1 11/23/2004 19:00:00 9.4 1.1 12.6 5.7 9.1 1.2 12.6 6.1 0.4 0 0.4 0.4 85 9 94 305 125 0 125 0 1 0 1.5 0.8 11/23/2004 19:10:00 9.5 1 11.8 6.8 9.1 1 11.8 6.5 0.4 0 0.4 0.4 80 7 71 305 125 0 125 0 1 0 1.5 1 11/23/2004 19:20:00 9.7 1.1 12.6 6.1 9.3 1.1 12.2 6.1 0.4 0 0.4 0.4 81 8 84 305 125 0 126 0 1 0 1.5 1 11/23/2004 19:30:00 10.6 1 14.1 8.4 10.3 1 14.1 7.2 0.4 0 0.4 0.4 79 6 80 305 126 0 126 0 1 0 1.5 1 11/23/2004 19:40:00 10.5 0.9 13 8 10.2 1 13 7.2 0.4 0 0.4 0.4 77 6 72 305 125 0 126 0 1 0 1.5 1 11/23/2004 19:50:00 10.7 0.4 11.8 9.5 10.5 0.5 11.8 8.8 0.4 0 0.4 0.4 68 4 69 305 125 0 125 0 0.9 0.1 1.5 0.6 11/23/2004 20:00:00 11.1 0.4 12.2 9.9 10.9 0.5 12.2 9.5 0.4 0 0.4 0.4 66 2 68 305 126 0 126 0 0.6 0 1 0.6 11/23/2004 20:10:00 11.1 0.6 12.2 9.1 10.8 0.6 12.2 8.8 0.4 0 0.4 0.4 67 3 66 305 128 0 129 0 0.5 0 1 0.3 11/23/2004 20:20:00 11.8 0.6 13.3 10.3 11.6 0.6 13 9.5 0.4 0 0.4 0.4 71 3 70 305 128 0 129 0 0.5 0 1 0.3 11/23/2004 20:30:00 11.4 0.6 12.6 9.5 11.1 0.8 12.6 9.1 0.4 0 0.4 0.4 66 3 69 305 129 0 128 0 0.5 0 0.8 0.3 11/23/2004 20:40:00 11.6 0.6 13.7 9.9 11.3 0.7 13 9.1 0.4 0 0.4 0.4 68 3 73 305 129 0 129 0 0.4 0 1 0.3 11/23/2004 20:50:00 11.8 0.8 14.1 9.9 11.6 0.7 13.7 9.9 0.4 0 0.4 0.4 71 4 73 305 129 0 129 0 0.5 0 1 0.3 11/23/2004 21:00:00 11.7 0.7 13.7 10.3 11.6 0.7 13.3 9.5 0.4 0 0.7 0.4 69 4 71 305 128 0 128 0 0.5 0 0.8 0.3 11/23/2004 21:10:00 11.4 0.8 14.1 9.1 11.2 0.9 13.3 8.8 0.4 0 0.4 0.4 68 4 66 305 128 0 128 0 0.4 0 1 0.3 11/23/2004 21:20:00 11.8 0.8 13.7 10.3 11.7 0.9 13.7 9.1 0.4 0 0.4 0.4 69 3 72 305 128 0 128 0 0.3 0 0.8 0.1 11/23/2004 21:30:00 11.9 0.6 13.3 9.9 11.7 0.7 13.3 9.9 0.4 0 0.4 0.4 71 4 66 305 128 0 128 0 -0.1 0 0.6 -0.4 11/23/2004 21:40:00 10.9 1 13.7 8.4 10.7 1.1 13.3 7.2 0.4 0 0.4 0.4 77 7 76 305 128 0 128 0 -0.4 0.1 0.3 -0.6 11/23/2004 21:50:00 11.4 0.6 13 9.9 11.3 0.8 13 8.4 0.4 0 0.4 0.4 72 4 72 305 128 0 128 0 -0.5 0 -0.1 -0.6 11/23/2004 22:00:00 11.7 0.7 13 9.1 11.6 0.9 13.3 9.5 0.4 0 0.4 0.4 72 4 74 305 128 0 128 0 -0.4 0.1 0.3 -0.6 11/23/2004 22:10:00 11.4 0.8 13 8.8 11.3 1 13.3 8.8 0.4 0 0.4 0.4 74 5 75 305 128 0 128 0 -0.4 0.1 0.1 -0.6 11/23/2004 22:20:00 10.1 0.7 12.6 8.4 9.9 0.8 12.2 7.2 0.4 0 0.4 0.4 77 5 89 305 128 0 128 0 -0.5 0.1 0.1 -0.6 11/23/2004 22:30:00 10 0.9 12.2 6.8 9.8 1 12.6 6.1 0.4 0 0.4 0.4 76 7 61 305 129 0 129 0 -0.4 0 0.1 -0.4 11/23/2004 22:40:00 10.1 0.8 12.2 8 10 1 13.3 7.6 0.4 0 0.4 0.4 73 6 69 305 129 0 129 0 -0.4 0 0.1 -0.6 11/23/2004 22:50:00 9.9 0.8 12.2 7.6 9.8 0.9 12.2 8 0.4 0 0.7 0.4 72 6 75 305 129 0 129 0 -0.4 0 -0.1 -0.4 11/23/2004 23:00:00 10.1 0.8 11.8 7.2 10.1 0.9 11.8 7.6 0.4 0 0.4 0.4 70 6 62 305 129 0 129 0 -0.3 0 0.1 -0.4 11/23/2004 23:10:00 9.1 0.7 11.5 7.6 9.2 0.7 11.1 7.6 0.4 0 0.4 0.4 68 4 67 305 129 0 129 0 -0.3 0 0.1 -0.4 11/23/2004 23:20:00 8.9 0.7 11.1 7.2 8.9 0.8 10.7 7.2 0.4 0 0.4 0.4 60 6 52 305 129 0 129 0 -0.3 0 0.1 -0.4 11/23/2004 23:30:00 8.8 0.7 10.7 6.5 8.9 0.7 10.7 6.5 0.4 0 0.4 0.4 60 7 55 305 129 0 129 0 -0.4 0 0.1 -0.6 11/23/2004 23:40:00 9.1 0.6 10.7 7.6 9.1 0.6 11.1 7.6 0.4 0 0.4 0.4 61 4 57 305 129 0 129 0 -0.5 0 -0.4 -0.6 11/23/2004 23:50:00 8.6 0.7 10.3 6.8 8.7 0.7 10.7 6.5 0.4 0 0.4 0.4 61 5 54 305 129 0 129 0 -0.5 0 -0.4 -0.6 11/24/2004 00:00:00 8.5 0.8 10.3 6.8 8.5 0.9 10.7 6.5 0.4 0 0.4 0.4 53 5 50 305 129 0 129 0 -0.5 0 0.1 -0.6 11/24/2004 00:10:00 8.4 0.5 9.5 7.2 8.5 0.5 9.9 6.8 0.4 0 0.4 0.4 62 4 50 305 129 0 129 0 -0.5 0 0.1 -0.6 11/24/2004 00:20:00 8.8 0.7 10.7 6.5 8.8 0.7 10.7 6.8 0.4 0 0.4 0.4 58 0 58 305 129 0 129 0 -0.5 0 0.1 -0.6 11/24/2004 00:30:00 8 0.5 9.5 6.8 8 0.6 9.5 6.5 0.4 0 0.4 0.4 58 0 58 305 129 0 129 0 -0.5 0.1 0.1 -0.6 11/24/2004 00:40:00 7.5 0.6 8.8 5.7 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 58 0 58 305 129 0 129 0 -0.3 0 0.3 -0.4 11/24/2004 00:50:00 8.6 0.5 10.3 7.2 8.6 0.6 9.9 6.8 0.4 0 0.4 0.4 57 0 57 305 129 0 129 0 -0.2 0 0.3 -0.4 11/24/2004 01:00:00 8.1 0.5 9.1 6.8 8.1 0.5 9.1 6.8 0.4 0 0.4 0.4 57 0 57 305 129 0 128 0 -0.1 0 0.3 -0.4 11/24/2004 01:10:00 8.6 0.5 9.5 6.8 8.6 0.6 9.5 6.5 0.4 0 0.4 0.4 57 0 57 305 129 0 128 0 -0.2 0 0.3 -0.4 11/24/2004 01:20:00 8.1 0.4 9.1 6.8 8.1 0.4 9.5 6.8 0.4 0 0.4 0.4 56 0 57 305 129 0 129 0 -0.1 0 0.3 -0.4 11/24/2004 01:30:00 8.5 0.7 9.9 6.8 8.5 0.7 9.9 6.8 0.4 0 0.4 0.4 38 12 32 305 129 0 129 0 -0.1 0 0.3 -0.4 11/24/2004 01:40:00 9.5 0.8 11.5 7.6 9.5 0.9 11.5 6.8 0.4 0 0.4 0.4 33 3 36 305 129 0 129 0 -0.3 0 0.3 -0.4 11/24/2004 01:50:00 9.7 0.6 11.1 8 9.7 0.6 11.5 8 0.4 0 0.4 0.4 35 3 30 305 129 0 129 0 -0.4 0.1 0.1 -0.6 11/24/2004 02:00:00 8.8 0.6 9.9 7.2 8.8 0.6 10.3 7.6 0.4 0 0.4 0.4 36 4 39 305 129 0 129 0 -0.3 0 0.1 -0.4 11/24/2004 02:10:00 8.4 0.7 10.3 6.8 8.4 0.8 10.3 6.5 0.4 0 0.4 0.4 35 4 32 305 129 0 129 0 -0.3 0 0.3 -0.4 11/24/2004 02:20:00 8.9 0.5 10.3 7.2 8.9 0.5 10.3 7.2 0.4 0 0.4 0.4 39 3 37 305 129 0 128 0 -0.1 0 0.3 -0.4 11/24/2004 02:30:00 10.3 1 12.6 8 10.3 1 13 8 0.4 0 0.4 0.4 36 4 41 305 129 0 129 0 -0.1 0 0.3 -0.4 11/24/2004 02:40:00 11.8 0.8 14.1 9.1 11.8 0.9 14.1 9.1 0.4 0 0.4 0.4 39 4 47 305 129 0 129 0 -0.2 0 0.3 -0.4 11/24/2004 02:50:00 11.9 1.1 14.5 8.8 11.9 1.2 14.9 8 0.4 0 0.4 0.4 39 4 34 305 129 0 128 0 -0.3 0 0.3 -0.4 11/24/2004 03:00:00 10.7 0.7 12.2 8.8 10.8 0.9 12.6 8 0.4 0 0.4 0.4 33 3 32 305 129 0 128 0 -0.3 0 0.3 -0.4 11/24/2004 03:10:00 10.8 0.8 12.6 8.4 10.9 0.9 13 8.4 0.4 0 0.4 0.4 36 3 37 305 129 0 128 0 -0.4 0 0.1 -0.6 11/24/2004 03:20:00 9.8 0.8 11.5 7.6 9.8 0.8 11.8 7.6 0.4 0 0.4 0.4 34 4 30 305 128 0 128 0 -0.5 0 0.1 -0.6 11/24/2004 03:30:00 10.9 0.4 11.8 9.1 11 0.6 12.2 8.8 0.4 0 0.4 0.4 36 3 37 305 128 0 128 0 -0.7 0 0.1 -1.1 11/24/2004 03:40:00 11 0.5 12.2 9.1 11.1 0.6 12.6 9.1 0.4 0 0.4 0.4 38 4 37 305 128 0 128 0 -1 0.1 -0.4 -1.1 11/24/2004 03:50:00 10.8 0.7 12.2 8.8 10.9 0.8 12.2 8.8 0.4 0 0.4 0.4 36 5 38 305 128 0 128 0 -1 0.1 -0.4 -1.1 11/24/2004 04:00:00 11 0.5 12.2 9.1 11 0.6 12.2 9.1 0.4 0 0.4 0.4 38 5 41 305 128 0 128 0 -1.1 0 -0.6 -1.1 11/24/2004 04:10:00 10.1 0.9 12.2 8 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 27 3 32 305 128 0 128 0 -1.1 0 -0.6 -1.1 11/24/2004 04:20:00 9.5 0.7 11.1 7.6 9.7 0.7 11.5 8 0.4 0 0.4 0.4 26 5 19 305 128 0 128 0 -1.2 0 -0.6 -1.3 11/24/2004 04:30:00 10 0.7 11.8 8.4 10 0.9 12.2 7.6 0.4 0 0.4 0.4 31 5 35 305 128 0 128 0 -1.2 0 -0.6 -1.3 11/24/2004 04:40:00 10.2 0.7 11.8 8.4 10.3 0.8 13 8 0.4 0 0.4 0.4 28 5 34 305 128 0 128 0 -1.2 0 -0.6 -1.3 11/24/2004 04:50:00 10 0.9 11.8 7.6 10.2 0.9 12.2 7.6 0.4 0 0.4 0.4 32 5 31 305 128 0 128 0 -1.1 0 -0.6 -1.3 11/24/2004 05:00:00 10.6 0.9 13 8.4 10.7 0.9 12.6 8.4 0.4 0 0.4 0.4 32 4 31 305 128 0 128 0 -1.1 0 -0.6 -1.3 11/24/2004 05:10:00 10.6 0.9 12.6 8.4 10.7 1 13 8.4 0.4 0 0.4 0.4 29 5 28 305 128 0 128 0 -1.1 0 -0.6 -1.3 11/24/2004 05:20:00 11.1 0.8 13 8.8 11.3 0.9 13.3 8.8 0.4 0 0.4 0.4 26 4 25 305 128 0 128 0 -1.1 0 -0.6 -1.3 11/24/2004 05:30:00 10.8 0.9 13 8.8 10.9 1 13.3 8 0.4 0 0.4 0.4 22 7 17 305 128 0 127 0 -1.1 0 -0.6 -1.1 11/24/2004 05:40:00 11.5 0.9 13.7 9.5 11.6 0.9 13.3 8.8 0.4 0 0.4 0.4 22 5 25 305 127 0 127 0 -1 0 -0.6 -1.1 11/24/2004 05:50:00 11.7 1.1 14.1 9.1 11.7 1.1 14.1 9.5 0.4 0 0.4 0.4 26 5 19 305 127 0 127 0 -1 0 -0.4 -1.1 11/24/2004 06:00:00 12.5 1.3 15.6 9.1 12.5 1.4 15.6 9.1 0.4 0 0.4 0.4 29 4 37 305 127 0 127 0 -0.7 0 -0.1 -1.1 11/24/2004 06:10:00 13.3 1 15.6 11.1 13.3 1 16.1 11.1 0.4 0 0.4 0.4 24 4 25 305 127 0 127 0 -0.7 0 -0.1 -0.8 11/24/2004 06:20:00 13.3 1 15.6 9.9 13.3 1.1 15.6 9.9 0.4 0 0.4 0.4 23 4 30 305 127 0 127 0 -0.8 0 -0.4 -1.1 11/24/2004 06:30:00 13.2 1.1 15.3 10.3 13.1 1.2 15.6 10.3 0.4 0 0.4 0.4 24 5 21 305 127 0 127 0 -0.7 0 -0.1 -0.8 11/24/2004 06:40:00 13.9 1 16.1 11.5 13.9 1.1 16.1 10.7 0.4 0 0.7 0.4 23 4 19 305 128 0 128 0 -0.6 0 0.1 -0.8 11/24/2004 06:50:00 13.5 1.5 16.4 9.9 13.4 1.5 16.8 9.5 0.4 0 0.4 0.4 27 4 32 305 125 2 124 0 -0.6 0 0.1 -0.6 11/24/2004 07:00:00 14.5 1.3 17.6 11.1 14.3 1.3 17.6 11.5 0.4 0 0.4 0.4 26 5 31 305 123 0 123 0 -0.6 0 0.1 -0.6 11/24/2004 07:10:00 14.5 1.3 17.2 11.5 14.5 1.4 17.6 11.8 0.4 0 0.4 0.4 27 4 26 305 111 8 106 0 -0.7 0 -0.1 -0.8 11/24/2004 07:20:00 14.3 1.1 16.4 11.8 14.2 1.2 16.8 10.7 0.4 0 0.4 0.4 22 4 25 305 103 1 102 0 -0.7 0 -0.4 -0.8 11/24/2004 07:30:00 14.5 1.1 16.8 11.5 14.4 1.1 16.8 11.5 0.4 0 0.4 0.4 25 4 21 305 102 0 102 0 -0.6 0 -0.4 -0.6 11/24/2004 07:40:00 14.1 1 16.4 11.8 14.1 1.1 16.8 11.5 0.4 0 0.4 0.4 24 4 23 305 102 0 102 0 -0.6 0 0.1 -0.6 11/24/2004 07:50:00 14.6 1.2 17.6 11.1 14.5 1.2 17.6 11.1 0.4 0 0.4 0.4 23 4 19 305 102 0 102 0 -0.5 0 0.1 -0.6 11/24/2004 08:00:00 14.9 1.1 17.2 12.2 14.8 1.2 17.6 11.5 0.4 0 0.4 0.4 24 4 24 305 101 0 101 0 -0.5 0 0.1 -0.6 11/24/2004 08:10:00 14.8 1.3 17.2 11.8 14.7 1.3 17.2 10.7 0.4 0 0.4 0.4 24 4 25 305 101 0 101 0 -0.5 0 0.1 -0.6 11/24/2004 08:20:00 13.5 1.1 15.6 10.7 13.4 1.2 16.1 10.7 0.4 0 0.4 0.4 26 5 22 305 101 0 101 0 -0.5 0 0.1 -0.6 11/24/2004 08:30:00 13.2 1.6 16.8 9.9 13 1.5 16.1 9.9 0.4 0 0.4 0.4 28 5 21 305 100 0 100 0 -0.5 0.1 0.1 -0.6 11/24/2004 08:40:00 12.7 1.4 17.2 10.3 12.5 1.3 17.2 9.5 0.4 0 0.4 0.4 31 5 24 305 100 0 101 0 -0.5 0.1 0.1 -0.6 11/24/2004 08:50:00 16 1.2 19.1 12.2 15.6 1.2 17.9 12.2 0.4 0 0.4 0.4 29 4 28 305 101 0 101 0 -0.5 0.1 0.1 -0.6 11/24/2004 09:00:00 13.9 1.3 16.4 10.3 13.7 1.3 16.4 9.9 0.4 0 0.4 0.4 30 5 30 305 101 0 101 0 -0.5 0 0.1 -0.6 11/24/2004 09:10:00 14.3 1.5 17.6 9.9 14 1.5 17.6 9.9 0.4 0 0.4 0.4 29 5 27 305 101 0 101 0 -0.5 0 0.1 -0.6 11/24/2004 09:20:00 13.5 1.2 16.1 10.3 13.2 1.2 15.6 10.3 0.4 0 0.4 0.4 30 5 19 305 101 0 101 0 -0.5 0 0.1 -0.6 11/24/2004 09:30:00 12.5 1.2 16.1 9.5 12.2 1.3 15.6 9.1 0.4 0 0.4 0.4 27 5 21 305 101 0 101 0 -0.4 0.1 0.1 -0.6 11/24/2004 09:40:00 13 1.1 16.8 9.5 12.7 1.2 16.4 9.5 0.4 0 0.4 0.4 30 5 33 305 101 0 101 0 -0.4 0.1 0.1 -0.6 11/24/2004 09:50:00 12.6 1 15.3 9.9 12.4 1.2 15.6 9.5 0.4 0 0.4 0.4 30 5 28 305 101 0 101 0 -0.4 0 0.1 -0.6 11/24/2004 10:00:00 13.4 1.7 16.8 9.1 13 1.7 16.8 8.8 0.4 0 0.4 0.4 31 5 25 305 101 0 101 0 -0.4 0 0.1 -0.4 11/24/2004 10:10:00 15.4 1.3 18.3 12.2 15.2 1.3 18.3 11.1 0.4 0 0.4 0.4 30 3 30 305 100 0 100 0 -0.3 0 0.3 -0.4 11/24/2004 10:20:00 14.6 1 17.2 11.8 14.4 1 17.2 11.8 0.4 0 0.4 0.4 29 4 24 305 101 1 100 0 -0.3 0 0.1 -0.4 11/24/2004 10:30:00 14.4 0.8 17.2 12.2 14.2 0.8 16.8 12.2 0.4 0 0.4 0.4 32 3 27 305 101 0 101 0 -0.3 0 0.1 -0.4 11/24/2004 10:40:00 13 1 15.6 10.3 12.8 1 15.3 10.7 0.4 0 0.4 0.4 33 4 33 305 101 0 101 0 -0.3 0 0.1 -0.4 11/24/2004 10:50:00 13.5 0.9 15.6 10.7 13.2 1 15.6 9.9 0.4 0 0.4 0.4 33 3 34 305 101 0 102 0 -0.3 0 0.1 -0.4 11/24/2004 11:00:00 13.2 0.9 15.6 11.5 13 0.9 16.1 10.7 0.4 0 0.4 0.4 33 3 33 305 102 0 102 0 -0.3 0 0.1 -0.4 11/24/2004 11:10:00 12.7 1 15.3 10.3 12.5 1 15.3 9.5 0.4 0 0.4 0.4 33 4 31 305 102 0 102 0 -0.3 0 0.1 -0.4 11/24/2004 11:20:00 13.7 1.1 16.8 10.7 13.4 1.2 16.4 9.9 0.4 0 0.4 0.4 34 4 35 305 101 0 101 0 -0.4 0 0.1 -0.4 11/24/2004 11:30:00 14.4 1.8 18.3 10.3 14.2 1.9 17.9 9.9 0.4 0 0.4 0.4 36 5 32 305 100 0 101 0 -0.4 0.1 0.1 -0.6 11/24/2004 11:40:00 14.7 1.1 17.2 11.8 14.5 1.2 17.6 10.7 0.4 0 0.4 0.4 39 4 39 305 98 0 98 0 -0.5 0 0.1 -0.6 11/24/2004 11:50:00 14.6 1 17.2 11.8 14.4 1.1 17.2 11.5 0.4 0 0.4 0.4 38 4 40 305 97 0 97 0 -0.6 0 -0.4 -0.8 11/24/2004 12:00:00 14.1 0.9 16.1 11.1 14.1 1 16.4 11.1 0.4 0 0.4 0.4 36 4 37 305 97 0 96 0 -0.6 0 0.1 -0.6 11/24/2004 12:10:00 13 1.2 15.6 10.3 12.9 1.3 16.1 9.5 0.4 0 0.4 0.4 36 4 34 305 97 0 97 0 -0.6 0 0.1 -0.6 11/24/2004 12:20:00 13.4 1 15.6 11.1 13.3 1 15.6 11.1 0.4 0 0.4 0.4 36 4 38 305 96 0 96 0 -0.5 0 0.1 -0.6 11/24/2004 12:30:00 13.5 1 15.6 11.1 13.4 1 15.6 11.1 0.4 0 0.4 0.4 38 4 39 305 96 0 96 0 -0.5 0.1 0.1 -0.6 11/24/2004 12:40:00 15 0.8 17.2 12.2 14.9 0.9 17.2 11.5 0.4 0 0.4 0.4 36 3 37 305 94 0 95 0 -0.5 0.1 0.1 -0.6 11/24/2004 12:50:00 14.7 1.3 16.8 10.7 14.6 1.4 16.8 11.1 0.4 0 0.4 0.4 34 4 33 305 93 0 93 0 -0.5 0 0.1 -0.6 11/24/2004 13:00:00 14.9 1 16.8 12.2 14.8 1.1 17.2 11.5 0.4 0 0.4 0.4 34 4 34 305 92 0 92 0 -0.6 0 -0.1 -0.6 11/24/2004 13:10:00 15.1 1.2 17.6 11.8 14.9 1.3 17.9 11.1 0.4 0 0.4 0.4 32 3 32 305 90 1 90 0 -0.6 0 0.1 -0.6 11/24/2004 13:20:00 15.5 0.8 17.2 13 15.4 1 17.6 12.2 0.4 0 0.4 0.4 33 3 33 305 88 0 88 0 -0.7 0 -0.1 -0.8 11/24/2004 13:30:00 14.8 1 16.8 12.2 14.6 1 17.2 11.5 0.4 0 0.4 0.4 33 3 31 305 87 0 87 0 -0.7 0 0.1 -0.8 11/24/2004 13:40:00 14.2 1 16.4 11.5 14.2 1.1 16.8 11.5 0.4 0 0.4 0.4 34 3 34 305 86 0 87 0 -0.6 0 -0.1 -0.8 11/24/2004 13:50:00 14.3 0.9 16.4 11.8 14.3 1 16.4 11.1 0.4 0 0.4 0.4 34 3 36 305 85 0 85 0 -0.6 0 0.1 -0.6 11/24/2004 14:00:00 13.6 0.8 15.6 11.5 13.6 0.9 15.3 11.1 0.4 0 0.4 0.4 34 3 33 305 84 0 85 0 -0.5 0 0.1 -0.6 11/24/2004 14:10:00 13.2 0.8 15.3 11.5 13.2 0.9 15.6 11.1 0.4 0 0.4 0.4 33 3 36 305 84 0 84 0 -0.5 0.1 0.1 -0.6 11/24/2004 14:20:00 13.5 0.8 16.1 11.5 13.5 0.8 16.1 11.1 0.4 0 0.4 0.4 33 4 34 305 84 0 84 0 -0.5 0 0.1 -0.6 11/24/2004 14:30:00 14.5 0.9 16.4 11.8 14.5 1 16.4 11.8 0.4 0 0.4 0.4 33 3 33 305 83 0 84 0 -0.5 0 0.1 -0.6 11/24/2004 14:40:00 14.9 0.9 17.6 12.2 14.8 1 16.8 11.5 0.4 0 0.4 0.4 35 3 32 305 82 0 82 0 -0.5 0.1 0.1 -0.6 11/24/2004 14:50:00 15.3 0.9 17.2 12.6 15.1 1 17.2 11.5 0.4 0 0.4 0.4 34 3 36 305 81 0 82 0 -0.4 0.1 0.1 -0.6 11/24/2004 15:00:00 15.2 1 17.6 12.6 15.1 1 17.2 12.6 0.4 0 0.4 0.4 36 3 38 305 80 0 81 0 -0.4 0 0.1 -0.6 11/24/2004 15:10:00 15.3 1 17.6 12.6 15.1 1.1 17.6 11.8 0.4 0 0.4 0.4 35 3 32 305 79 0 79 0 -0.4 0 0.1 -0.4 11/24/2004 15:20:00 14.8 1 16.8 12.2 14.8 1.1 17.2 11.8 0.4 0 0.4 0.4 37 4 33 305 78 0 79 0 -0.4 0 0.1 -0.6 11/24/2004 15:30:00 14 1 16.1 11.5 13.8 1.1 16.1 10.7 0.4 0 0.4 0.4 37 4 39 305 77 0 77 0 -0.4 0 0.1 -0.6 11/24/2004 15:40:00 13.4 1.1 15.6 10.3 13.4 1.2 16.1 10.3 0.4 0 0.4 0.4 38 3 37 305 77 0 77 0 -0.4 0 0.1 -0.6 11/24/2004 15:50:00 12.7 1.3 15.3 10.3 12.6 1.4 15.3 9.5 0.4 0 0.4 0.4 36 4 36 305 77 0 78 0 -0.4 0 0.1 -0.6 11/24/2004 16:00:00 13.1 1.2 16.1 10.7 13 1.2 16.4 10.3 0.4 0 0.4 0.4 36 4 36 305 78 0 78 0 -0.5 0.1 0.1 -0.6 11/24/2004 16:10:00 13.2 0.9 14.9 10.3 13.1 0.9 15.3 9.9 0.4 0 0.4 0.4 36 4 32 305 78 0 78 0 -0.5 0 0.1 -0.6 11/24/2004 16:20:00 12.9 0.8 15.3 10.3 12.8 0.9 15.3 10.3 0.4 0 0.4 0.4 35 3 36 305 78 0 78 0 -0.5 0.1 0.1 -0.6 11/24/2004 16:30:00 12.5 0.9 14.5 10.3 12.5 1 14.5 10.3 0.4 0 0.4 0.4 36 4 27 305 78 0 78 0 -0.5 0 0.1 -0.6 11/24/2004 16:40:00 12.5 0.8 14.5 10.7 12.4 0.9 14.5 10.3 0.4 0 0.4 0.4 33 4 29 305 78 0 78 0 -0.6 0 -0.1 -0.6 11/24/2004 16:50:00 12.8 1 14.9 10.3 12.7 1 14.9 9.9 0.4 0 0.4 0.4 33 5 33 305 79 0 78 0 -0.6 0 0.1 -0.6 11/24/2004 17:00:00 12.5 0.9 14.5 10.3 12.4 1 14.5 10.3 0.4 0 0.4 0.4 32 4 29 305 79 0 79 0 -0.7 0 -0.1 -0.8 11/24/2004 17:10:00 12.7 0.8 14.9 10.7 12.6 1 15.3 10.3 0.4 0 0.4 0.4 34 3 37 305 79 0 79 0 -0.7 0 -0.1 -0.8 11/24/2004 17:20:00 12.7 0.9 14.5 10.3 12.6 1 14.5 9.9 0.4 0 0.4 0.4 35 5 36 305 80 0 79 0 -0.7 0 -0.1 -0.8 11/24/2004 17:30:00 12.9 1.1 15.6 10.7 12.8 1.1 15.6 9.9 0.4 0 0.4 0.4 34 4 29 305 80 0 80 0 -0.8 0 -0.6 -1.1 11/24/2004 17:40:00 12.7 0.7 14.9 10.7 12.6 0.8 14.5 10.7 0.4 0 0.4 0.4 37 5 38 305 80 0 80 0 -0.7 0 -0.1 -0.8 11/24/2004 17:50:00 13.1 0.9 16.1 11.1 13.1 1 15.6 10.3 0.4 0 0.4 0.4 35 4 37 305 81 0 81 0 -0.7 0 -0.6 -0.8 11/24/2004 18:00:00 13.3 0.8 15.3 11.1 13.2 0.9 15.6 11.1 0.4 0 0.4 0.4 36 4 35 305 81 0 81 0 -0.7 0 -0.4 -1.1 11/24/2004 18:10:00 13 0.7 14.9 11.1 13 0.8 15.3 11.1 0.4 0 0.4 0.4 36 4 30 305 80 0 80 0 -0.8 0 -0.1 -1.1 11/24/2004 18:20:00 13.9 1.1 16.8 11.5 13.9 1.1 16.8 11.1 0.4 0 0.4 0.4 33 3 37 305 81 0 81 0 -0.8 0 -0.1 -1.1 11/24/2004 18:30:00 14.3 0.9 16.4 11.8 14.2 1 16.4 11.5 0.4 0 0.4 0.4 35 4 33 305 80 0 81 0 -1 0.1 -0.4 -1.1 11/24/2004 18:40:00 13.4 1 15.6 10.7 13.4 1 15.6 10.7 0.4 0 0.4 0.4 36 4 36 305 80 0 80 0 -0.9 0.1 -0.4 -1.1 11/24/2004 18:50:00 13.7 0.8 15.6 11.8 13.7 0.9 15.6 11.5 0.4 0 0.4 0.4 32 3 35 305 80 0 80 0 -1.1 0 -0.4 -1.1 11/24/2004 19:00:00 14 1 16.4 11.5 13.9 1 16.1 11.5 0.4 0 0.4 0.4 35 3 37 305 80 0 80 0 -1.1 0 -0.6 -1.1 11/24/2004 19:10:00 13.5 0.8 15.3 11.5 13.4 0.9 15.6 11.1 0.4 0 0.4 0.4 35 5 36 305 80 0 80 0 -1.1 0 -0.4 -1.1 11/24/2004 19:20:00 14.1 1.1 16.4 11.1 13.9 1.1 16.8 10.3 0.4 0 0.4 0.4 33 5 32 305 81 0 81 0 -1.1 0 -0.6 -1.3 11/24/2004 19:30:00 14.1 1.1 16.8 11.5 14.1 1.2 16.8 11.1 0.4 0 0.4 0.4 37 4 38 305 81 0 81 0 -1.1 0 -0.6 -1.3 11/24/2004 19:40:00 14.5 0.9 16.8 11.8 14.5 0.9 16.4 11.5 0.4 0 0.4 0.4 36 3 35 305 81 0 82 0 -1.1 0 -0.6 -1.3 11/24/2004 19:50:00 13.5 0.9 15.3 10.3 13.4 1 15.3 10.3 0.4 0 0.4 0.4 37 5 29 305 82 0 82 0 -1.1 0 -0.8 -1.1 11/24/2004 20:00:00 13.4 1 16.1 10.7 13.2 1 16.1 9.9 0.4 0 0.4 0.4 38 5 37 305 82 0 82 0 -1 0 -0.6 -1.1 11/24/2004 20:10:00 13.8 0.9 15.6 11.1 13.8 0.9 15.6 11.1 0.4 0 0.4 0.4 33 3 35 305 82 0 82 0 -1.1 0 -0.6 -1.1 11/24/2004 20:20:00 13.8 1.1 16.1 10.7 13.7 1.2 16.1 11.1 0.4 0 0.4 0.4 35 3 33 305 81 0 81 0 -1 0 -0.4 -1.1 11/24/2004 20:30:00 14.1 1 16.8 11.8 14 1 16.8 11.1 0.4 0 0.4 0.4 45 4 49 305 81 0 81 0 -1 0.1 -0.4 -1.1 11/24/2004 20:40:00 13.6 0.9 16.1 11.1 13.5 1 16.1 10.7 0.4 0 0.4 0.4 38 4 36 305 80 0 80 0 -1 0.1 -0.4 -1.1 11/24/2004 20:50:00 13.7 0.9 15.6 11.5 13.6 1 15.6 11.1 0.4 0 0.4 0.4 33 3 30 305 80 0 80 0 -1 0.1 -0.4 -1.1 11/24/2004 21:00:00 13.1 0.9 15.3 10.7 13 1 15.3 10.3 0.4 0 0.4 0.4 38 4 32 305 79 0 79 0 -1 0.1 -0.4 -1.1 11/24/2004 21:10:00 13.1 1 16.1 10.7 12.8 1.1 16.1 10.3 0.4 0 0.4 0.4 31 5 30 305 79 0 79 0 -0.9 0.1 -0.4 -1.1 11/24/2004 21:20:00 13.1 1 15.6 10.3 13 1 15.3 10.7 0.4 0 0.4 0.4 35 7 27 305 78 0 78 0 -0.9 0 -0.4 -1.1 11/24/2004 21:30:00 13.1 1.1 15.6 10.3 13.1 1.2 15.6 10.3 0.4 0 0.4 0.4 33 4 36 305 77 0 77 0 -0.9 0 -0.4 -1.1 11/24/2004 21:40:00 13.6 1 15.6 11.1 13.6 1 16.1 11.1 0.4 0 0.4 0.4 32 3 31 305 76 0 77 0 -0.8 0 -0.4 -1.1 11/24/2004 21:50:00 13.8 1.2 16.1 10.7 13.8 1.2 16.1 10.3 0.4 0 0.4 0.4 32 4 26 305 76 0 76 0 -0.8 0 -0.4 -1.1 11/24/2004 22:00:00 14.1 1 16.4 11.5 14.1 1 16.4 11.5 0.4 0 0.4 0.4 41 4 45 305 74 0 74 0 -1 0.1 -0.4 -1.1 11/24/2004 22:10:00 13.5 1.2 16.1 11.1 13.4 1.2 16.4 10.7 0.4 0 0.4 0.4 43 5 39 305 73 0 74 0 -1 0.1 -0.4 -1.1 11/24/2004 22:20:00 13.7 0.9 16.4 11.5 13.6 1.1 16.8 10.7 0.4 0 0.4 0.4 43 5 45 305 73 0 73 0 -1.1 0 -0.6 -1.3 11/24/2004 22:30:00 14.1 0.8 16.4 11.8 14 0.9 16.1 11.8 0.4 0 0.4 0.4 44 4 46 305 73 0 73 0 -1 0.1 -0.4 -1.1 11/24/2004 22:40:00 13.7 1 16.1 10.7 13.5 1 16.1 10.7 0.4 0 0.4 0.4 36 3 33 305 72 0 72 0 -1 0.1 -0.4 -1.1 11/24/2004 22:50:00 14.1 0.9 16.1 12.2 14 0.9 16.1 11.8 0.4 0 0.4 0.4 42 4 40 305 72 0 72 0 -1 0.1 -0.4 -1.1 11/24/2004 23:00:00 13.9 0.9 16.1 11.5 13.7 1 16.4 11.1 0.4 0 0.4 0.4 46 5 57 305 71 0 71 0 -1 0.1 -0.4 -1.1 11/24/2004 23:10:00 12.8 1 16.1 10.7 12.6 1.1 16.1 9.9 0.4 0 0.4 0.4 44 6 40 305 71 0 71 0 -0.8 0 -0.1 -1.1 11/24/2004 23:20:00 12.3 0.7 14.1 10.3 12.2 0.7 13.7 9.9 0.4 0 0.4 0.4 46 5 53 305 71 0 71 0 -0.8 0 -0.4 -1.1 11/24/2004 23:30:00 13.7 0.7 15.6 11.5 13.4 0.9 15.6 11.5 0.4 0 0.4 0.4 48 4 42 305 70 0 71 0 -0.8 0 -0.4 -1.1 11/24/2004 23:40:00 13 1 14.9 10.3 12.9 1.1 15.3 9.9 0.4 0 0.4 0.4 39 5 45 305 70 0 70 0 -0.7 0 -0.1 -1.1 11/24/2004 23:50:00 12.1 0.8 14.1 9.9 12 0.9 14.1 9.5 0.4 0 0.4 0.4 39 6 56 305 70 0 70 0 -0.8 0 -0.4 -1.1 11/25/2004 00:00:00 13 1 15.6 10.3 12.9 1 15.3 9.9 0.4 0 0.4 0.4 44 5 47 305 70 0 70 0 -0.8 0 -0.4 -1.1 11/25/2004 00:10:00 12.1 1 14.1 9.5 11.9 1.1 14.5 8.8 0.4 0 0.4 0.4 37 4 36 305 69 0 70 0 -0.7 0 -0.4 -1.1 11/25/2004 00:20:00 11.9 0.8 14.1 9.9 11.7 0.7 13.7 9.9 0.4 0 0.4 0.4 35 4 30 305 69 0 69 0 -0.7 0 -0.1 -0.8 11/25/2004 00:30:00 12.5 1.1 14.9 9.9 12.3 1.1 14.9 9.1 0.4 0 0.4 0.4 46 5 46 305 68 0 68 0 -0.7 0 -0.4 -0.8 11/25/2004 00:40:00 11.8 1 13.7 8.8 11.5 1.1 14.1 8.4 0.4 0 0.4 0.4 47 4 48 305 68 0 67 0 -0.6 0 -0.4 -0.6 11/25/2004 00:50:00 12.6 0.9 14.9 10.7 12.5 0.9 14.9 9.9 0.4 0 0.4 0.4 42 6 43 305 67 0 67 0 -0.7 0 -0.1 -0.8 11/25/2004 01:00:00 11.5 1 13.3 9.1 11.4 1 13.3 8.8 0.4 0 0.4 0.4 45 6 37 305 66 0 66 0 -0.6 0 -0.1 -0.6 11/25/2004 01:10:00 11.9 1 14.5 9.5 11.8 1.1 14.9 9.1 0.4 0 0.4 0.4 37 8 45 305 66 0 66 0 -0.7 0 -0.1 -0.8 11/25/2004 01:20:00 11.1 0.7 12.6 8.8 10.9 0.8 12.6 8.8 0.4 0 0.4 0.4 42 5 36 305 66 0 66 0 -0.6 0 -0.1 -0.6 11/25/2004 01:30:00 11.5 0.8 13.7 9.1 11.5 0.8 13.7 9.1 0.4 0 0.4 0.4 40 8 31 305 65 0 65 0 -0.6 0 0.1 -0.6 11/25/2004 01:40:00 12.1 0.9 14.1 9.9 12 1 14.1 9.5 0.4 0 0.4 0.4 34 4 34 305 65 0 65 0 -0.6 0 -0.1 -0.8 11/25/2004 01:50:00 12.1 0.7 13.7 9.5 12.1 0.8 13.7 9.5 0.4 0 0.4 0.4 36 4 32 305 65 0 65 0 -0.7 0 -0.1 -1.1 11/25/2004 02:00:00 12.4 0.8 14.1 10.3 12.2 0.8 14.1 10.3 0.4 0 0.4 0.4 31 3 31 305 64 0 64 0 -0.9 0 -0.4 -1.1 11/25/2004 02:10:00 12.3 0.8 14.9 9.9 12.2 0.9 14.5 9.9 0.4 0 0.4 0.4 37 5 31 305 63 0 63 0 -1 0.1 -0.4 -1.1 11/25/2004 02:20:00 12.3 0.7 13.7 10.3 12.2 0.7 13.7 9.9 0.4 0 0.4 0.4 39 3 37 305 62 0 62 0 -1.1 0 -0.6 -1.3 11/25/2004 02:30:00 12.2 0.7 13.3 9.9 12.1 0.8 14.1 9.9 0.4 0 0.4 0.4 42 5 41 305 61 0 61 0 -1.1 0 -0.6 -1.3 11/25/2004 02:40:00 11.4 1 14.1 8.8 11.3 1.1 14.1 8.8 0.4 0 0.4 0.4 44 5 47 305 60 0 60 0 -1.2 0 -0.6 -1.3 11/25/2004 02:50:00 11.3 0.7 13 9.5 11.1 0.8 12.6 8.8 0.4 0 0.4 0.4 48 5 51 305 61 0 60 0 -1.2 0 -0.6 -1.3 11/25/2004 03:00:00 11.9 0.8 13.7 9.5 11.8 0.8 13.7 10.3 0.4 0 0.4 0.4 42 6 47 305 61 0 61 0 -1.4 0 -0.8 -1.5 11/25/2004 03:10:00 12 0.9 13.7 9.9 11.8 1 13.7 9.1 0.4 0 0.4 0.4 38 7 33 305 62 0 61 0 -1.5 0.1 -1.1 -1.8 11/25/2004 03:20:00 12.1 1.1 14.1 9.5 12 1.2 14.5 9.5 0.4 0 0.4 0.4 35 5 39 305 63 0 62 0 -1.6 0 -1.1 -1.8 11/25/2004 03:30:00 11.9 0.8 14.1 9.1 11.9 0.8 13.7 9.1 0.4 0 0.4 0.4 46 5 46 305 64 0 64 0 -1.6 0 -1.3 -1.8 11/25/2004 03:40:00 11.2 0.9 13.3 9.1 11 1 13 8.4 0.4 0 0.4 0.4 50 5 47 305 64 0 64 0 -1.6 0 -1.1 -1.8 11/25/2004 03:50:00 11.7 0.7 14.1 9.5 11.6 0.8 14.1 9.5 0.4 0 0.4 0.4 46 4 46 305 65 0 65 0 -1.6 0 -1.3 -1.8 11/25/2004 04:00:00 11.3 0.6 13 9.5 11.2 0.6 12.6 9.5 0.4 0 0.4 0.4 38 5 39 305 64 0 64 0 -1.6 0 -1.1 -1.8 11/25/2004 04:10:00 11.4 0.7 13 9.1 11.3 0.8 13 9.1 0.4 0 0.4 0.4 46 7 49 305 64 0 64 0 -1.7 0 -1.1 -2 11/25/2004 04:20:00 11 0.7 13 8.8 11 0.7 13 8.4 0.4 0 0.4 0.4 43 5 41 305 63 0 63 0 -1.8 0 -1.5 -2 11/25/2004 04:30:00 11.7 0.8 13.3 9.5 11.6 0.8 13.7 9.1 0.4 0 0.4 0.4 49 5 53 305 63 0 63 0 -1.9 0 -1.5 -2 11/25/2004 04:40:00 12.2 1 14.5 9.5 12.1 1 14.1 9.5 0.4 0 0.4 0.4 48 4 48 305 62 0 63 0 -1.9 0 -1.8 -2 11/25/2004 04:50:00 13.5 0.8 15.3 11.5 13.4 0.8 15.6 11.1 0.4 0 0.4 0.4 50 3 55 305 62 0 62 0 -2 0 -1.8 -2.2 11/25/2004 05:00:00 12.4 0.8 14.5 9.9 12.3 1 14.5 9.9 0.4 0 0.4 0.4 46 5 48 305 61 0 62 0 -2 0 -1.8 -2.2 11/25/2004 05:10:00 12.4 1 14.5 9.9 12.3 1 14.5 9.5 0.4 0 0.4 0.4 44 4 47 305 61 0 61 0 -2 0 -1.8 -2.2 11/25/2004 05:20:00 11.8 0.8 13.7 9.9 11.7 0.8 13.7 9.5 0.4 0 0.4 0.4 48 5 37 305 60 0 60 0 -2.1 0 -2 -2.2 11/25/2004 05:30:00 11.6 0.9 13.7 9.1 11.5 1 13.7 8.8 0.4 0 0.4 0.4 45 5 37 305 59 0 60 0 -2.2 0 -2 -2.4 11/25/2004 05:40:00 12 1.1 14.9 9.5 11.9 1.1 14.9 9.1 0.4 0 0.4 0.4 49 4 50 305 59 0 59 0 -2.2 0 -2 -2.2 11/25/2004 05:50:00 12.1 0.8 14.5 9.9 12.1 0.9 14.1 9.9 0.4 0 0.4 0.4 41 9 42 305 59 0 59 0 -2.2 0 -1.8 -2.2 11/25/2004 06:00:00 12 0.7 14.1 9.9 12 0.8 14.1 9.9 0.4 0 0.4 0.4 36 6 32 305 59 0 59 0 -2.1 0 -2 -2.2 11/25/2004 06:10:00 11 1 14.1 8.8 11 1 13.7 8 0.4 0 0.4 0.4 42 7 31 305 59 0 59 0 -2 0 -1.8 -2.2 11/25/2004 06:20:00 11.2 0.9 13.3 8.8 11.1 1 13.3 8.4 0.4 0 0.4 0.4 37 8 31 305 59 0 59 0 -2.1 0.1 -1.8 -2.4 11/25/2004 06:30:00 11 0.8 13 8.4 11.1 0.8 13 8.8 0.4 0 0.4 0.4 32 4 30 305 59 0 59 0 -2.2 0 -2 -2.4 11/25/2004 06:40:00 11.2 0.8 12.6 8.8 11.1 0.8 12.6 8.8 0.4 0 0.4 0.4 32 4 31 305 59 0 59 0 -2.2 0 -1.8 -2.4 11/25/2004 06:50:00 10.3 1 12.6 8 10.3 1 13 7.6 0.4 0 0.4 0.4 38 6 30 305 59 0 59 0 -2.1 0 -2 -2.2 11/25/2004 07:00:00 11.3 0.7 13.3 9.1 11.3 0.8 13 9.1 0.4 0 0.4 0.4 33 6 30 305 59 0 59 0 -2.2 0 -1.8 -2.4 11/25/2004 07:10:00 11.4 0.6 13 9.9 11.3 0.6 12.6 9.5 0.4 0 0.4 0.4 33 6 31 305 58 0 59 0 -2.3 0 -2 -2.4 11/25/2004 07:20:00 11.2 0.8 13 9.1 11.2 0.9 13.3 8.4 0.4 0 0.4 0.4 34 6 42 305 58 0 58 0 -2.2 0 -1.8 -2.4 11/25/2004 07:30:00 11.3 0.9 13.3 8.8 11.4 0.9 13.7 9.1 0.4 0 0.4 0.4 33 5 33 305 57 0 57 0 -2.2 0 -1.8 -2.4 11/25/2004 07:40:00 11.4 0.7 13.3 9.1 11.4 0.7 13 8.8 0.4 0 0.4 0.4 38 5 36 305 57 0 57 0 -2.2 0 -2 -2.4 11/25/2004 07:50:00 11.4 0.7 13.3 9.5 11.3 0.8 13 9.1 0.4 0 0.4 0.4 35 7 23 305 56 0 57 0 -2.2 0 -2 -2.4 11/25/2004 08:00:00 11.3 0.6 12.6 9.5 11.4 0.7 13 8.8 0.4 0 0.4 0.4 32 4 32 305 56 0 55 0 -2.3 0 -1.8 -2.4 11/25/2004 08:10:00 10.5 0.9 13 8 10.4 1 13 8 0.4 0 0.4 0.4 38 8 41 305 55 0 55 0 -2.2 0 -1.8 -2.4 11/25/2004 08:20:00 10.6 0.8 12.6 8.8 10.5 0.8 13 8.4 0.4 0 0.4 0.4 41 8 31 305 54 0 55 0 -2.2 0 -1.8 -2.4 11/25/2004 08:30:00 10.3 0.8 12.2 8.4 10.3 0.8 11.8 8 0.4 0 0.4 0.4 37 7 30 305 54 0 54 0 -2.2 0 -2 -2.4 11/25/2004 08:40:00 10.4 1 13 8.4 10.4 1 13 7.6 0.4 0 0.4 0.4 46 12 61 305 53 0 53 0 -2.2 0 -1.8 -2.4 11/25/2004 08:50:00 10 0.8 11.8 7.6 9.9 0.8 11.8 7.2 0.4 0 0.4 0.4 53 6 58 305 52 0 51 0 -2.2 0 -2 -2.4 11/25/2004 09:00:00 10.6 0.6 11.8 9.1 10.5 0.7 12.2 8.8 0.4 0 0.4 0.4 51 5 50 305 50 0 51 0 -2.4 0 -2.2 -2.7 11/25/2004 09:10:00 10.2 1 12.2 7.6 10.2 1 12.6 7.6 0.4 0 0.4 0.4 53 6 48 305 50 0 50 0 -2.4 0 -2 -2.7 11/25/2004 09:20:00 10.9 0.9 14.5 9.1 10.8 1 14.1 8.4 0.4 0 0.4 0.4 49 11 51 305 49 0 49 0 -2.3 0 -2 -2.4 11/25/2004 09:30:00 10.4 0.8 12.2 8 10.4 0.8 12.2 8.4 0.4 0 0.4 0.4 41 8 33 305 48 0 48 0 -2.3 0 -2.2 -2.4 11/25/2004 09:40:00 11.3 0.8 14.1 9.1 11.2 0.8 14.1 8.8 0.4 0 0.4 0.4 31 4 32 305 48 0 48 0 -2.3 0 -2.2 -2.4 11/25/2004 09:50:00 11.4 0.8 13.7 9.1 11.4 0.8 13.7 9.5 0.4 0 0.4 0.4 29 5 31 305 47 0 47 0 -2.4 0 -2.2 -2.7 11/25/2004 10:00:00 11.3 0.9 13 9.1 11.2 1 13 8.8 0.4 0 0.4 0.4 31 5 30 305 46 0 46 0 -2.5 0 -2 -2.7 11/25/2004 10:10:00 10.5 1.1 13 7.2 10.5 1.1 13 8 0.4 0 0.4 0.4 32 6 30 305 45 0 45 0 -2.6 0 -2.2 -2.7 11/25/2004 10:20:00 10.3 0.9 12.2 7.2 10.3 1 12.6 7.6 0.4 0 0.4 0.4 46 8 40 305 44 0 43 0 -2.7 0 -2.2 -2.7 11/25/2004 10:30:00 9.8 0.7 11.8 7.6 9.8 0.8 11.8 7.6 0.4 0 0.4 0.4 48 6 47 305 42 0 43 0 -2.7 0 -2.2 -2.7 11/25/2004 10:40:00 9.1 0.6 10.7 7.6 9.1 0.6 10.7 7.2 0.4 0 0.4 0.4 49 6 56 305 42 0 42 0 -2.7 0 -2.4 -2.7 11/25/2004 10:50:00 8.9 1.1 11.5 6.8 9 1.1 11.8 6.8 0.4 0 0.4 0.4 42 7 38 305 42 0 42 0 -2.7 0.1 -2.2 -2.7 11/25/2004 11:00:00 8.3 0.8 10.7 6.5 8.3 0.8 10.3 6.1 0.4 0 0.4 0.4 51 5 46 305 41 0 41 0 -2.7 0 -2.7 -2.7 11/25/2004 11:10:00 8.8 1.2 12.2 6.5 8.9 1.2 11.8 6.5 0.4 0 0.4 0.4 44 5 42 305 41 0 41 0 -2.7 0 -2.4 -2.9 11/25/2004 11:20:00 8.4 0.6 10.7 6.8 8.5 0.7 11.1 6.8 0.4 0 0.4 0.4 51 6 61 305 41 0 41 0 -2.7 0 -2.7 -2.7 11/25/2004 11:30:00 8.2 0.8 10.3 6.5 8.2 0.8 10.3 6.1 0.4 0 0.4 0.4 44 11 26 305 41 0 41 0 -2.7 0 -2.2 -2.9 11/25/2004 11:40:00 8.9 0.9 10.3 6.1 8.9 1 10.7 6.5 0.4 0 0.4 0.4 38 6 32 305 41 0 41 0 -2.7 0 -2.4 -2.7 11/25/2004 11:50:00 7.2 0.8 9.1 5.7 7.3 0.8 9.1 5.7 0.4 0 0.4 0.4 38 8 39 305 40 0 40 0 -2.7 0 -2.4 -2.9 11/25/2004 12:00:00 7.5 1 9.9 5.7 7.6 1 10.7 6.1 0.4 0 0.4 0.4 36 7 26 305 39 0 39 0 -2.8 0 -2.2 -2.9 11/25/2004 12:10:00 7.7 0.9 9.9 5.7 7.7 0.9 9.9 6.1 0.4 0 0.4 0.4 43 6 39 305 38 0 39 0 -2.8 0 -2.7 -2.9 11/25/2004 12:20:00 6.5 0.5 8 5.3 6.5 0.5 8 4.9 0.4 0 0.4 0.4 44 7 43 305 37 0 38 0 -2.8 0 -2.7 -2.9 11/25/2004 12:30:00 7.4 0.7 9.1 6.1 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 29 5 28 305 37 0 37 0 -2.7 0 -2.7 -2.9 11/25/2004 12:40:00 7.3 0.8 9.9 6.1 7.3 0.8 9.9 5.7 0.4 0 0.4 0.4 36 6 44 305 36 0 36 0 -2.8 0 -2.7 -2.9 11/25/2004 12:50:00 6 1 8 3.8 6 1 8.4 3.4 0.4 0 0.4 0.4 40 8 34 305 36 0 36 0 -2.8 0 -2.4 -2.9 11/25/2004 13:00:00 7.3 0.6 8.8 5.7 7.4 0.6 8.8 6.1 0.4 0 0.4 0.4 26 7 22 305 36 0 36 0 -2.8 0 -2.2 -3.1 11/25/2004 13:10:00 7.7 0.8 10.3 5.7 7.8 0.9 10.3 5.3 0.4 0 0.4 0.4 32 9 26 305 35 0 35 0 -2.8 0 -2.7 -3.1 11/25/2004 13:20:00 7.6 0.8 9.9 5.3 7.6 0.9 9.9 5.7 0.4 0 0.4 0.4 34 5 32 305 35 0 35 0 -2.8 0 -2.2 -3.1 11/25/2004 13:30:00 7.5 0.9 9.9 5.3 7.6 0.9 9.9 5.7 0.4 0 0.4 0.4 31 6 33 305 34 0 34 0 -2.9 0 -2.4 -3.1 11/25/2004 13:40:00 6.5 0.9 8.8 4.2 6.5 0.9 9.1 4.6 0.4 0 0.4 0.4 50 7 48 305 34 0 34 0 -3 0 -2.7 -3.1 11/25/2004 13:50:00 7 1.2 9.1 4.6 7.1 1.2 9.1 4.6 0.4 0 0.4 0.4 46 5 39 305 33 0 33 0 -2.9 0 -2.7 -3.1 11/25/2004 14:00:00 6.8 1 8.8 4.2 6.8 1 9.1 4.2 0.4 0 0.4 0.4 52 6 47 305 32 0 33 0 -3 0 -2.7 -3.1 11/25/2004 14:10:00 6.3 0.5 8.4 4.9 6.4 0.6 8 4.9 0.4 0 0.4 0.4 33 11 41 305 32 0 32 0 -3 0 -2.7 -3.1 11/25/2004 14:20:00 6.1 0.5 7.2 4.9 6.3 0.5 7.6 4.9 0.4 0 0.4 0.4 23 6 22 305 31 0 32 0 -3 0 -2.7 -3.1 11/25/2004 14:30:00 5.2 0.8 6.8 3.4 5.4 0.9 7.2 3.4 0.4 0 0.4 0.4 23 6 20 305 31 0 31 0 -3 0 -2.9 -3.1 11/25/2004 14:40:00 5.6 0.9 7.6 3.4 5.7 0.9 7.6 3.4 0.4 0 0.4 0.4 39 12 39 305 31 0 31 0 -2.8 0 -2.7 -3.1 11/25/2004 14:50:00 5.2 0.7 6.8 3.4 5.2 0.6 6.5 3.4 0.4 0 0.4 0.4 60 8 51 305 31 0 31 0 -2.9 0 -2.7 -3.1 11/25/2004 15:00:00 4.1 0.6 5.7 2.3 4.2 0.5 5.3 2.6 0.4 0 0.4 0.4 58 11 62 305 30 0 30 0 -3 0 -2.4 -3.1 11/25/2004 15:10:00 5.1 0.9 6.8 2.6 5.2 0.9 6.8 3 0.4 0 0.4 0.4 31 12 16 305 30 0 29 0 -2.8 0 -2.4 -3.1 11/25/2004 15:20:00 6.3 0.8 8 4.2 6.4 0.8 8.4 4.6 0.4 0 0.4 0.4 36 15 40 305 29 0 29 0 -2.8 0 -2.7 -2.9 11/25/2004 15:30:00 5.4 0.8 8 3.8 5.5 0.8 8 4.2 0.4 0 0.4 0.4 24 6 31 305 29 0 29 0 -2.8 0 -2.4 -2.9 11/25/2004 15:40:00 5.1 0.9 7.2 3.4 5.3 1 7.6 3.4 0.4 0 0.4 0.4 19 7 25 305 29 0 29 0 -2.8 0 -2.7 -2.9 11/25/2004 15:50:00 5.1 0.6 6.8 3.4 5.2 0.6 7.2 3.8 0.4 0 0.4 0.4 25 8 23 305 28 0 28 0 -2.8 0 -2.7 -2.9 11/25/2004 16:00:00 5.5 0.6 6.8 4.2 5.7 0.6 7.2 4.6 0.4 0 0.4 0.4 32 8 36 305 28 0 28 0 -2.8 0 -2.4 -2.9 11/25/2004 16:10:00 4 0.5 5.7 3 4.1 0.6 6.1 2.6 0.4 0 0.4 0.4 48 16 25 305 28 0 28 0 -2.8 0 -2.7 -3.1 11/25/2004 16:20:00 5.2 1 7.2 3.4 5.2 0.9 7.2 3.4 0.4 0 0.4 0.4 57 8 40 305 28 0 28 0 -2.8 0 -2.7 -3.1 11/25/2004 16:30:00 4.3 1 6.5 2.6 4.4 1 7.2 2.6 0.4 0 0.4 0.4 50 9 46 305 28 0 28 0 -2.8 0 -2.7 -3.1 11/25/2004 16:40:00 4.5 1.1 7.6 2.6 4.6 1.1 7.2 2.6 0.4 0 0.4 0.4 57 7 47 305 27 0 27 0 -2.8 0 -2.7 -3.1 11/25/2004 16:50:00 6.4 0.7 8 4.9 6.5 0.6 8.8 5.3 0.4 0 0.4 0.4 49 7 50 305 28 0 28 0 -2.7 0 -2.7 -2.9 11/25/2004 17:00:00 6.4 0.7 8 4.2 6.4 0.7 8.4 4.6 0.4 0 0.4 0.4 48 5 50 305 28 0 28 0 -2.8 0 -2.4 -2.9 11/25/2004 17:10:00 5 0.7 6.8 3 5 0.7 6.5 3 0.4 0 0.4 0.4 62 9 62 305 27 0 27 0 -2.9 0 -2.7 -3.1 11/25/2004 17:20:00 4.8 0.7 6.1 3 4.6 0.8 6.8 3 0.4 0 0.4 0.4 75 12 60 305 26 0 26 0 -3 0 -2.9 -3.1 11/25/2004 17:30:00 6.7 1.2 8.8 4.2 6.6 1.2 9.1 3.8 0.4 0 0.4 0.4 54 9 54 305 26 0 26 0 -2.8 0 -2.7 -3.1 11/25/2004 17:40:00 5.8 0.9 8 4.2 5.8 0.9 7.6 4.2 0.4 0 0.4 0.4 63 7 62 305 27 0 27 0 -2.8 0 -2.7 -2.9 11/25/2004 17:50:00 4.6 0.7 6.5 3 4.4 0.8 6.5 2.6 0.4 0 0.4 0.4 69 8 65 305 27 0 27 0 -2.8 0 -2.7 -3.1 11/25/2004 18:00:00 5.3 0.8 7.2 3 5.3 0.8 7.2 3.4 0.4 0 0.4 0.4 49 19 68 305 27 0 27 0 -2.8 0 -2.7 -3.1 11/25/2004 18:10:00 4.9 0.8 6.5 2.6 5 0.8 6.5 3 0.4 0 0.4 0.4 31 7 33 305 26 0 26 0 -2.8 0 -2.7 -3.1 11/25/2004 18:20:00 6.1 0.5 7.6 4.6 6.1 0.5 7.2 4.9 0.4 0 0.4 0.4 52 12 52 305 27 0 27 0 -2.7 0 -2.7 -2.9 11/25/2004 18:30:00 5.3 1.1 7.2 2.6 5.3 1.1 7.2 3 0.4 0 0.4 0.4 62 8 72 305 27 0 27 0 -2.8 0 -2.7 -2.9 11/25/2004 18:40:00 5.2 0.6 6.5 3.8 5 0.6 6.8 3.4 0.4 0 0.4 0.4 74 8 70 305 27 0 27 0 -2.8 0 -2.4 -2.9 11/25/2004 18:50:00 4 0.8 6.1 2.3 3.8 0.7 6.1 2.3 0.4 0 0.4 0.4 75 12 53 305 27 0 27 0 -2.8 0 -2.4 -2.9 11/25/2004 19:00:00 4.6 0.7 6.8 3 4.6 0.8 6.5 3 0.4 0 0.4 0.4 60 8 53 305 27 0 27 0 -2.6 0 -2.2 -2.7 11/25/2004 19:10:00 4 0.7 5.3 2.6 3.8 0.6 5.7 2.6 0.4 0 0.4 0.4 78 9 67 305 28 0 28 0 -2.6 0 -2.2 -2.7 11/25/2004 19:20:00 4.3 0.7 6.1 2.6 4 0.7 6.1 2.3 0.4 0 0.4 0.4 84 8 95 305 28 0 28 0 -2.6 0 -2.4 -2.7 11/25/2004 19:30:00 4.1 0.4 4.9 3 4 0.5 4.9 2.6 0.4 0 0.4 0.4 60 13 75 305 28 0 28 0 -2.4 0 -2 -2.7 11/25/2004 19:40:00 4.3 0.6 5.7 2.6 4.2 0.5 5.3 3 0.4 0 0.4 0.4 68 13 87 305 29 0 29 0 -2.4 0 -2 -2.4 11/25/2004 19:50:00 4.2 0.5 5.7 2.6 4 0.5 5.7 2.6 0.4 0 0.4 0.4 82 9 85 305 29 0 29 0 -2.4 0 -2 -2.7 11/25/2004 20:00:00 4 0.9 6.5 2.3 3.9 0.8 6.1 2.3 0.4 0 0.4 0.4 78 15 88 305 18 4 18 0 -2.3 0 -2 -2.4 11/25/2004 20:10:00 5.2 0.9 7.2 2.3 5.1 0.9 6.8 2.3 0.4 0 0.4 0.4 72 8 58 305 14 0 14 0 -2.3 0 -1.8 -2.4 11/25/2004 20:20:00 5.5 0.6 7.2 4.2 5.3 0.6 6.8 3.8 0.4 0 0.4 0.4 67 6 70 305 14 0 14 0 -2.3 0 -2 -2.4 11/25/2004 20:30:00 3.6 0.7 5.3 1.9 3.5 0.7 5.3 1.9 0.4 0 0.4 0.4 79 7 71 305 13 0 13 0 -2.4 0 -2 -2.4 11/25/2004 20:40:00 5.8 1.2 8 3.4 5.8 1.2 8 3 0.4 0 0.4 0.4 64 6 67 305 13 0 13 0 -2.3 0 -2 -2.4 11/25/2004 20:50:00 4.8 0.5 6.8 3.8 4.6 0.5 6.5 3 0.4 0 0.4 0.4 71 11 83 305 13 0 13 0 -2.3 0 -2 -2.4 11/25/2004 21:00:00 5.3 0.9 8 3.4 5.1 0.8 7.2 3.4 0.4 0 0.4 0.4 82 8 76 305 13 0 13 0 -2.4 0 -2 -2.4 11/25/2004 21:10:00 4.4 0.8 6.1 2.3 4.3 0.6 6.5 2.6 0.4 0 0.4 0.4 85 11 81 305 13 0 13 0 -2.5 0 -2.4 -2.7 11/25/2004 21:20:00 4 0.8 6.8 1.5 3.7 0.9 5.7 1.5 0.4 0 0.4 0.4 100 21 81 305 13 0 13 0 -2.5 0 -2.4 -2.7 11/25/2004 21:30:00 3.8 1.2 7.2 1.1 3.9 1.1 6.8 1.1 0.4 0 0.4 0.4 110 15 124 305 13 0 13 0 -2.5 0 -2.4 -2.7 11/25/2004 21:40:00 3.8 1.2 6.1 0.7 3.7 1 5.7 1.5 0.4 0 0.4 0.4 77 14 78 305 13 0 13 0 -2.5 0 -2.2 -2.7 11/25/2004 21:50:00 5.7 0.8 7.6 4.2 5.5 0.8 7.6 3.8 0.4 0 0.4 0.4 69 6 67 305 13 0 13 0 -2.4 0 -2.2 -2.4 11/25/2004 22:00:00 5.1 1 8.4 3 4.8 1 8.4 3 0.4 0 0.4 0.4 78 10 60 305 13 0 13 0 -2.3 0 -2 -2.4 11/25/2004 22:10:00 6 1.1 9.1 3.8 5.7 1.2 8.8 3.8 0.4 0 0.4 0.4 75 8 70 305 13 0 13 0 -2.2 0 -2 -2.4 11/25/2004 22:20:00 6.1 1.1 9.5 3.4 5.7 1.1 8.8 3.4 0.4 0 0.4 0.4 78 13 66 305 13 0 13 0 -2.2 0 -2 -2.2 11/25/2004 22:30:00 4 1.1 6.5 1.5 3.8 1.2 7.2 1.5 0.4 0 0.4 0.4 90 18 90 305 13 0 13 0 -2.2 0 -2 -2.2 11/25/2004 22:40:00 3.7 1 5.7 1.1 3.6 0.9 5.7 1.5 0.4 0 0.4 0.4 87 23 115 305 12 0 12 0 -2.2 0 -1.8 -2.2 11/25/2004 22:50:00 4.2 1.2 7.2 1.1 4.1 1 7.2 1.9 0.4 0 0.4 0.4 82 20 103 305 12 0 12 0 -2.1 0 -1.5 -2.2 11/25/2004 23:00:00 4.7 1.2 7.2 1.5 4.5 1.1 7.6 1.1 0.4 0 0.4 0.4 82 13 78 305 12 0 12 0 -2 0 -1.8 -2 11/25/2004 23:10:00 4.1 1.1 7.2 1.9 3.8 0.9 6.5 1.9 0.4 0 0.4 0.4 96 19 95 305 12 0 12 0 -2 0 -2 -2.2 11/25/2004 23:20:00 4.5 1.2 8 2.6 4.4 1.1 8 1.9 0.4 0 0.4 0.4 92 17 67 305 12 0 12 0 -2 0 -1.8 -2.2 11/25/2004 23:30:00 3.5 0.7 5.7 1.5 3.3 0.7 5.7 1.5 0.4 0 0.4 0.4 85 17 77 305 12 0 12 0 -2 0 -1.8 -2.2 11/25/2004 23:40:00 4.8 1.3 8 2.3 4.7 1.3 8 2.3 0.4 0 0.4 0.4 78 13 62 305 12 0 12 0 -1.9 0 -1.8 -2 11/25/2004 23:50:00 6.2 0.8 8 3.4 5.9 0.8 7.6 3.4 0.4 0 0.4 0.4 76 9 71 305 11 0 12 0 -1.8 0 -1.5 -2 11/26/2004 00:00:00 5.1 0.8 8 3 4.9 0.7 7.6 3 0.4 0 0.4 0.4 87 11 77 305 11 0 11 0 -1.8 0 -1.3 -2 11/26/2004 00:10:00 4.4 1.1 7.2 1.9 4.3 1.1 6.8 1.5 0.4 0 0.4 0.4 83 14 70 305 11 0 11 0 -1.8 0 -1.3 -2 11/26/2004 00:20:00 5.3 0.9 7.6 3 5.1 1 7.6 2.6 0.4 0 0.4 0.4 76 10 75 305 11 0 11 0 -1.8 0 -1.3 -2 11/26/2004 00:30:00 6.1 0.8 8 3.8 5.8 0.8 7.6 3.8 0.4 0 0.4 0.4 74 7 88 305 11 0 11 0 -1.9 0 -1.5 -2 11/26/2004 00:40:00 7 0.6 8.4 5.3 6.8 0.7 8.4 4.9 0.4 0 0.4 0.4 69 4 74 305 11 0 12 0 -1.8 0 -1.3 -2 11/26/2004 00:50:00 6.9 0.5 8 5.3 6.7 0.6 8 5.3 0.4 0 0.4 0.4 70 4 70 305 12 0 12 0 -1.9 0 -1.5 -2 11/26/2004 01:00:00 6.4 0.7 8 4.6 6 0.7 7.6 4.2 0.4 0 0.4 0.4 79 7 75 305 13 0 13 0 -1.9 0 -1.5 -2 11/26/2004 01:10:00 5.9 0.7 7.6 3.8 5.5 0.6 7.2 3.4 0.4 0 0.4 0.4 81 8 76 305 13 0 13 0 -2 0 -1.8 -2 11/26/2004 01:20:00 6.2 0.7 8 4.6 5.9 0.7 7.6 4.2 0.4 0 0.4 0.4 76 6 77 305 14 0 14 0 -2 0 -1.5 -2 11/26/2004 01:30:00 6.8 0.8 8.4 4.9 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 72 4 72 305 15 0 15 0 -2 0 -1.8 -2 11/26/2004 01:40:00 7.6 0.7 9.1 5.7 7.4 0.8 9.1 5.7 0.4 0 0.4 0.4 65 6 58 305 15 0 15 0 -1.9 0 -1.5 -2 11/26/2004 01:50:00 8.3 0.6 9.5 6.5 8.2 0.7 9.9 6.1 0.4 0 0.4 0.4 65 5 62 305 16 0 16 0 -1.9 0 -1.5 -2 11/26/2004 02:00:00 8.4 0.6 10.7 6.8 8.3 0.7 10.3 6.8 0.4 0 0.4 0.4 68 4 65 305 17 0 17 0 -1.9 0 -1.5 -2 11/26/2004 02:10:00 8.3 0.5 9.9 6.8 8.1 0.5 9.1 6.8 0.4 0 0.4 0.4 68 3 66 305 18 0 18 0 -1.9 0 -1.5 -2 11/26/2004 02:20:00 8.1 0.6 9.5 6.8 8 0.6 9.5 6.5 0.4 0 0.4 0.4 71 5 70 305 18 0 18 0 -1.9 0 -1.5 -2 11/26/2004 02:30:00 8.3 0.6 9.5 6.8 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 67 3 64 305 18 0 18 0 -1.9 0 -1.5 -2 11/26/2004 02:40:00 8.8 0.6 9.9 6.8 8.7 0.7 9.9 6.5 0.4 0 0.4 0.4 68 4 65 305 18 0 19 0 -1.9 0 -1.5 -2 11/26/2004 02:50:00 8.9 0.7 10.7 7.2 8.7 0.8 10.7 6.5 0.4 0 0.4 0.4 69 4 66 305 18 0 18 0 -1.9 0 -1.5 -2 11/26/2004 03:00:00 9.1 0.6 10.3 7.6 8.9 0.7 10.7 7.2 0.4 0 0.4 0.4 69 3 67 305 18 0 18 0 -1.9 0 -1.5 -2 11/26/2004 03:10:00 8.6 0.6 9.9 6.1 8.4 0.8 9.9 5.7 0.4 0 0.4 0.4 65 4 61 305 18 0 18 0 -1.9 0 -1.5 -2 11/26/2004 03:20:00 8.3 0.5 9.5 6.8 8.2 0.6 9.5 6.1 0.4 0 0.4 0.4 65 4 62 305 19 0 19 0 -1.8 0 -1.5 -2 11/26/2004 03:30:00 8.8 0.4 9.9 7.6 8.7 0.5 9.5 6.8 0.4 0 0.4 0.4 62 3 60 305 19 0 19 0 -1.8 0 -1.3 -2 11/26/2004 03:40:00 8.5 0.4 9.5 7.6 8.4 0.5 9.5 7.2 0.4 0 0.4 0.4 67 4 63 305 19 0 19 0 -1.8 0 -1.3 -2 11/26/2004 03:50:00 8.3 0.5 9.5 6.8 8.2 0.5 9.5 6.8 0.4 0 0.4 0.4 65 3 69 305 19 0 19 0 -1.8 0 -1.3 -2 11/26/2004 04:00:00 8.1 0.6 9.5 6.5 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 69 4 64 305 19 0 19 0 -1.7 0 -1.3 -2 11/26/2004 04:10:00 8.3 0.7 9.9 6.5 8.1 0.7 9.5 5.7 0.4 0 0.4 0.4 71 5 69 305 19 0 19 0 -1.7 0 -1.3 -1.8 11/26/2004 04:20:00 8.4 0.7 9.9 6.5 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 69 5 69 305 19 0 19 0 -1.8 0 -1.5 -2 11/26/2004 04:30:00 8.6 0.7 9.9 6.5 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 69 5 69 305 19 0 19 0 -1.8 0 -1.3 -2 11/26/2004 04:40:00 8.9 0.7 12.2 7.2 8.8 0.8 11.1 7.2 0.4 0 0.4 0.4 66 4 68 305 19 0 19 0 -1.7 0 -1.3 -2 11/26/2004 04:50:00 9.4 0.7 11.1 7.6 9.4 0.7 11.8 6.8 0.4 0 0.4 0.4 67 4 70 305 20 0 20 0 -1.7 0 -1.1 -1.8 11/26/2004 05:00:00 9.8 0.8 12.2 6.8 9.6 0.9 11.5 6.5 0.4 0 0.4 0.4 70 5 65 305 20 0 20 0 -1.6 0 -1.1 -1.8 11/26/2004 05:10:00 10 0.7 11.8 8 9.9 0.8 11.5 7.6 0.4 0 0.4 0.4 70 5 66 305 21 0 21 0 -1.6 0 -1.1 -1.8 11/26/2004 05:20:00 9.9 0.6 11.5 8.4 9.6 0.7 11.5 7.6 0.4 0 0.4 0.4 68 4 64 305 22 0 22 0 -1.6 0 -1.3 -1.8 11/26/2004 05:30:00 10.1 0.8 11.8 7.6 9.9 0.9 11.8 7.2 0.4 0 0.4 0.4 67 4 66 305 22 0 22 0 -1.6 0 -1.5 -1.8 11/26/2004 05:40:00 10.2 0.7 12.2 8 10.1 0.8 11.8 7.6 0.4 0 0.4 0.4 65 3 66 305 23 0 22 0 -1.6 0 -1.3 -1.8 11/26/2004 05:50:00 10 0.9 12.2 7.2 9.9 1 11.8 7.6 0.4 0 0.4 0.4 67 3 66 305 24 0 24 0 -1.7 0 -1.5 -1.8 11/26/2004 06:00:00 9.7 0.7 11.1 7.6 9.5 0.8 11.1 7.6 0.4 0 0.4 0.4 62 4 62 305 25 0 25 0 -1.7 0 -1.3 -1.8 11/26/2004 06:10:00 9.4 0.6 10.7 7.2 9.3 0.7 11.1 7.2 0.4 0 0.4 0.4 59 4 59 305 26 0 26 0 -1.7 0 -1.5 -1.8 11/26/2004 06:20:00 9.6 0.7 11.1 7.6 9.5 0.8 11.1 7.2 0.4 0 0.4 0.4 56 4 54 305 27 0 27 0 -1.6 0 -1.3 -1.8 11/26/2004 06:30:00 10.3 0.8 12.2 8.4 10.2 0.8 11.8 8 0.4 0 0.4 0.4 55 4 53 305 28 0 29 0 -1.6 0 -1.3 -1.8 11/26/2004 06:40:00 11.2 0.6 12.2 9.1 11.1 0.7 12.6 8.8 0.4 0 0.4 0.4 55 3 58 305 29 0 29 0 -1.6 0 -1.3 -1.8 11/26/2004 06:50:00 11.1 0.7 12.6 9.1 10.9 0.8 12.6 8.4 0.4 0 0.4 0.4 54 4 49 305 30 0 31 0 -1.6 0 -1.3 -1.8 11/26/2004 07:00:00 10.4 0.7 12.2 8.8 10.3 0.8 12.2 8.8 0.4 0 0.4 0.4 56 4 56 305 31 0 32 0 -1.5 0 -1.1 -1.8 11/26/2004 07:10:00 10.9 0.9 13 8.8 10.8 0.9 13 8.8 0.4 0 0.4 0.4 56 5 64 305 32 0 32 0 -1.4 0 -1.3 -1.5 11/26/2004 07:20:00 10.8 0.9 12.6 9.1 10.7 1 13 8 0.4 0 0.4 0.4 58 5 61 305 32 0 32 0 -1.5 0 -1.1 -1.8 11/26/2004 07:30:00 11 0.8 13.3 9.1 10.8 0.9 13.3 8.4 0.4 0 0.4 0.4 55 4 56 305 32 0 32 0 -1.5 0 -1.1 -1.8 11/26/2004 07:40:00 11.3 0.7 13 9.5 11.2 0.8 13 9.1 0.4 0 0.4 0.4 54 4 57 305 33 0 32 0 -1.8 0 -1.5 -2 11/26/2004 07:50:00 11 1 13 8.8 11 1.1 13.3 8.4 0.4 0 0.4 0.4 56 3 57 305 34 1 34 0 -2 0.1 -1.8 -2.2 11/26/2004 08:00:00 11.5 1 14.5 8.4 11.3 1.1 14.9 8.4 0.4 0 0.4 0.4 75 8 80 305 37 0 37 0 -2 0.1 -1.5 -2.2 11/26/2004 08:10:00 11.3 1 14.5 8.4 11 1.1 14.1 7.6 0.4 0 0.4 0.4 79 7 79 305 38 0 39 0 -2.1 0.1 -1.8 -2.2 11/26/2004 08:20:00 11.6 1.1 14.1 7.2 11.5 1.1 14.9 8 0.4 0 0.4 0.4 78 6 74 305 39 0 39 0 -2.1 0 -1.8 -2.2 11/26/2004 08:30:00 11.9 1.1 14.5 8.8 11.7 1.3 14.5 8 0.4 0 0.4 0.4 77 6 79 305 39 0 39 0 -2.2 0 -1.8 -2.2 11/26/2004 08:40:00 11.8 1.2 14.1 8 11.5 1.3 13.7 7.2 0.4 0 0.4 0.4 77 6 79 305 38 0 38 0 -2.3 0 -2 -2.4 11/26/2004 08:50:00 12.2 0.8 14.1 9.5 12 1 14.1 8.8 0.4 0 0.4 0.4 72 5 71 305 38 0 38 0 -2.2 0 -2 -2.4 11/26/2004 09:00:00 12 1 14.5 8.8 11.7 1.1 14.1 9.1 0.4 0 0.4 0.4 73 5 73 305 37 0 36 0 -2.2 0 -2 -2.2 11/26/2004 09:10:00 12.6 0.9 14.9 9.9 12.4 1 14.9 8.8 0.4 0 0.4 0.4 72 5 62 305 36 0 36 0 -2.1 0 -1.8 -2.2 11/26/2004 09:20:00 12.9 0.7 14.9 11.5 12.7 0.8 14.5 10.7 0.4 0 0.4 0.4 69 4 71 305 34 0 34 0 -2.1 0 -1.8 -2.2 11/26/2004 09:30:00 12.2 0.8 14.9 9.9 12 0.9 13.7 9.1 0.4 0 0.4 0.4 72 5 80 305 33 0 33 0 -2.1 0 -1.8 -2.2 11/26/2004 09:40:00 12.3 1.1 15.3 10.3 12 1.3 14.9 9.1 0.4 0 0.4 0.4 72 6 69 305 32 0 32 0 -2.2 0 -2 -2.4 11/26/2004 09:50:00 12.9 0.7 14.9 10.7 12.8 0.8 14.9 10.3 0.4 0 0.4 0.4 67 3 67 305 31 0 32 0 -2.3 0 -2.2 -2.4 11/26/2004 10:00:00 12.1 0.9 14.5 9.5 11.9 1 14.5 8.8 0.4 0 0.4 0.4 67 5 69 305 31 0 31 0 -2.5 0 -2 -2.7 11/26/2004 10:10:00 12.2 0.8 14.5 10.3 12.1 0.8 14.1 9.1 0.4 0 0.4 0.4 68 5 67 305 31 0 31 0 -2.6 0.1 -2 -2.7 11/26/2004 10:20:00 12.1 0.8 14.9 10.3 11.9 0.9 14.1 8.8 0.4 0 0.4 0.4 63 4 60 305 31 0 31 0 -2.8 0 -2.4 -2.9 11/26/2004 10:30:00 11.6 1.1 14.5 8.8 11.5 1.2 14.1 8.4 0.4 0 0.4 0.4 67 6 82 305 32 0 32 0 -2.7 0 -2.4 -2.9 11/26/2004 10:40:00 12.5 1 14.9 9.9 12.3 1.1 14.9 9.1 0.4 0 0.4 0.4 65 6 61 305 33 0 33 0 -2.7 0 -2.2 -2.7 11/26/2004 10:50:00 12.5 1 14.5 9.9 12.2 1.1 14.9 9.1 0.4 0 0.4 0.4 61 6 57 305 34 0 34 0 -2.7 0 -2.2 -2.7 11/26/2004 11:00:00 12.8 1 14.9 10.7 12.6 1 14.9 9.5 0.4 0 0.4 0.4 65 6 65 305 35 0 35 0 -2.8 0 -2.4 -2.9 11/26/2004 11:10:00 12.6 1.2 15.3 9.9 12.4 1.2 15.3 9.1 0.4 0 0.4 0.4 58 6 61 305 35 0 35 0 -2.8 0 -2.4 -2.9 11/26/2004 11:20:00 13.2 0.8 15.3 11.1 13 1 15.3 10.3 0.4 0 0.4 0.4 61 5 68 305 36 0 36 0 -2.7 0 -2.4 -2.9 11/26/2004 11:30:00 13.3 1 16.1 11.1 13.1 1.1 16.1 9.9 0.4 0 0.4 0.4 61 6 63 305 37 0 36 0 -2.8 0 -2.7 -2.9 11/26/2004 11:40:00 13.6 0.9 15.6 11.1 13.5 1 16.1 10.3 0.4 0 0.4 0.4 55 4 57 305 37 0 38 0 -2.7 0 -2.7 -2.9 11/26/2004 11:50:00 13.1 1 15.6 10.7 12.9 1.1 15.3 10.3 0.4 0 0.4 0.4 65 5 52 305 38 0 38 0 -2.8 0 -2.4 -2.9 11/26/2004 12:00:00 13.2 0.8 14.9 10.7 13.1 0.9 14.9 10.3 0.4 0 0.4 0.4 55 7 54 305 38 0 38 0 -2.7 0 -2.2 -2.7 11/26/2004 12:10:00 13 0.9 15.3 10.3 12.9 0.9 14.9 10.3 0.4 0 0.4 0.4 53 5 57 305 38 0 38 0 -2.7 0 -2.4 -2.7 11/26/2004 12:20:00 13.1 1 15.6 10.7 12.8 1.1 16.1 9.9 0.4 0 0.4 0.4 52 5 55 305 39 0 39 0 -2.6 0.1 -2.2 -2.7 11/26/2004 12:30:00 12.9 1 15.3 10.3 12.7 1.1 15.3 9.5 0.4 0 0.4 0.4 56 5 55 305 39 0 39 0 -2.6 0.1 -2 -2.7 11/26/2004 12:40:00 12.2 1 14.5 9.9 12 1.1 14.5 8.8 0.4 0 0.4 0.4 61 7 53 305 39 0 39 0 -2.7 0 -2.2 -2.7 11/26/2004 12:50:00 13.4 0.8 15.3 11.1 13.2 0.9 15.6 10.3 0.4 0 0.4 0.4 66 5 72 305 39 0 40 0 -2.8 0 -2.7 -2.9 11/26/2004 13:00:00 12.7 0.8 14.9 10.7 12.6 0.8 14.1 10.3 0.4 0 0.4 0.4 58 5 57 305 40 0 39 0 -2.7 0 -2.2 -2.7 11/26/2004 13:10:00 12.7 1 14.9 10.3 12.5 1 14.9 10.3 0.4 0 0.4 0.4 57 5 60 305 40 0 40 0 -2.6 0 -2.4 -2.7 11/26/2004 13:20:00 13 0.8 14.9 10.7 12.7 0.9 14.9 9.9 0.4 0 0.4 0.4 64 5 65 305 40 0 40 0 -2.5 0 -2 -2.7 11/26/2004 13:30:00 12.6 1.1 16.1 10.3 12.5 1.2 15.6 9.9 0.4 0 0.4 0.4 62 4 62 305 41 0 41 0 -2.4 0 -2 -2.7 11/26/2004 13:40:00 12.3 1.1 15.3 9.5 12.2 1.3 15.6 8.8 0.4 0 0.4 0.4 60 4 61 305 42 0 42 0 -2.3 0 -2 -2.7 11/26/2004 13:50:00 13.1 0.9 15.3 10.7 13 1 15.3 10.3 0.4 0 0.4 0.4 56 4 61 305 43 0 43 0 -2.4 0 -2 -2.7 11/26/2004 14:00:00 13.2 0.8 14.9 10.3 13.1 0.9 14.9 10.3 0.4 0 0.4 0.4 59 4 57 305 44 0 43 0 -2.4 0 -2 -2.7 11/26/2004 14:10:00 12.4 1.1 14.9 9.9 12.2 1.1 14.5 9.5 0.4 0 0.4 0.4 61 4 63 305 45 0 45 0 -2.3 0 -1.8 -2.4 11/26/2004 14:20:00 12.4 1 14.9 9.9 12.3 1 14.9 9.1 0.4 0 0.4 0.4 60 5 59 305 46 0 45 0 -2.2 0 -1.8 -2.4 11/26/2004 14:30:00 13 1 14.9 10.3 12.9 1.1 14.9 9.9 0.4 0 0.4 0.4 61 5 56 305 47 0 47 0 -2.3 0 -2 -2.4 11/26/2004 14:40:00 12.9 1 15.3 9.5 12.8 1.2 15.3 9.5 0.4 0 0.4 0.4 60 4 58 305 47 0 47 0 -2.3 0 -2 -2.4 11/26/2004 14:50:00 12.5 0.9 14.1 9.9 12.5 1.1 14.5 9.1 0.4 0 0.4 0.4 61 4 66 305 48 0 48 0 -2.3 0 -2 -2.4 11/26/2004 15:00:00 12.2 0.9 13.7 9.5 12.1 0.9 13.7 9.1 0.4 0 0.4 0.4 61 5 67 305 49 0 48 0 -2.2 0 -2 -2.4 11/26/2004 15:10:00 12.3 0.7 14.1 9.9 12.2 0.8 14.1 9.9 0.4 0 0.4 0.4 61 4 57 305 50 0 50 0 -2.2 0 -2 -2.2 11/26/2004 15:20:00 12.1 0.8 14.1 9.9 12.1 0.8 14.1 9.9 0.4 0 0.4 0.4 63 4 56 305 51 0 51 0 -2.1 0 -2 -2.2 11/26/2004 15:30:00 12.8 0.8 14.5 9.9 12.7 0.8 14.9 10.3 0.4 0 0.4 0.4 65 4 67 305 52 0 52 0 -2.1 0 -2 -2.2 11/26/2004 15:40:00 11.9 0.7 13.7 9.9 11.8 0.8 13.7 9.9 0.4 0 0.4 0.4 64 4 63 305 53 0 53 0 -2.1 0 -2 -2.2 11/26/2004 15:50:00 12.9 0.9 14.5 9.9 12.7 0.9 14.5 9.9 0.4 0 0.4 0.4 65 3 60 305 54 0 53 0 -2.1 0 -2 -2.2 11/26/2004 16:00:00 12.5 1 14.5 9.9 12.2 1 14.9 9.1 0.4 0 0.4 0.4 60 5 56 305 54 0 54 0 -2 0 -1.8 -2 11/26/2004 16:10:00 13.1 0.8 14.9 9.5 13 1 15.3 9.9 0.4 0 0.4 0.4 58 4 58 305 55 0 55 0 -2 0 -2 -2 11/26/2004 16:20:00 13.5 0.8 15.3 10.7 13.4 0.9 15.3 10.3 0.4 0 0.4 0.4 51 4 48 305 55 0 55 0 -2.1 0 -2 -2.2 11/26/2004 16:30:00 13.4 0.8 15.6 11.1 13.3 0.9 15.6 9.9 0.4 0 0.4 0.4 50 4 48 305 56 0 56 0 -2.2 0 -2 -2.2 11/26/2004 16:40:00 13.8 1 16.1 10.7 13.6 1.1 16.1 10.3 0.4 0 0.4 0.4 54 5 57 305 56 0 56 0 -2.2 0 -2 -2.4 11/26/2004 16:50:00 12.8 1.1 15.3 10.3 12.6 1.3 15.6 9.9 0.4 0 0.4 0.4 57 4 61 305 57 0 57 0 -2.2 0 -1.8 -2.4 11/26/2004 17:00:00 12.7 1 14.5 10.3 12.6 1 14.5 9.5 0.4 0 0.4 0.4 57 5 54 305 57 0 58 0 -2.2 0 -1.8 -2.4 11/26/2004 17:10:00 13.1 0.8 14.9 10.3 13.1 1 15.3 10.3 0.4 0 0.4 0.4 54 3 54 305 58 0 58 0 -2.2 0 -1.8 -2.4 11/26/2004 17:20:00 13.2 0.8 14.9 11.1 13.2 0.9 14.9 10.7 0.4 0 0.4 0.4 54 3 49 305 58 0 57 0 -2.3 0 -2.2 -2.4 11/26/2004 17:30:00 13.1 0.9 14.9 10.7 12.9 1 15.3 10.3 0.4 0 0.4 0.4 52 4 51 305 58 0 58 0 -2.3 0 -1.8 -2.4 11/26/2004 17:40:00 13 1 15.3 10.3 12.8 1.1 15.3 9.5 0.4 0 0.4 0.4 56 4 53 305 59 0 59 0 -2.2 0 -2 -2.4 11/26/2004 17:50:00 13.2 1 15.3 9.9 13 1.2 15.3 9.9 0.4 0 0.4 0.4 57 5 55 305 59 0 59 0 -2.3 0 -1.8 -2.4 11/26/2004 18:00:00 13.9 1 15.3 9.9 13.8 1.1 15.6 10.3 0.4 0 0.4 0.4 55 4 56 305 59 0 59 0 -2.3 0 -2 -2.4 11/26/2004 18:10:00 13.4 1 16.1 10.7 13.4 1 16.1 11.1 0.4 0 0.4 0.4 56 3 54 305 59 0 59 0 -2.3 0 -2.2 -2.7 11/26/2004 18:20:00 13.6 1.1 16.4 11.1 13.5 1.2 16.4 10.7 0.4 0 0.4 0.4 56 5 56 305 59 0 59 0 -2.3 0 -1.8 -2.7 11/26/2004 18:30:00 13.8 1 16.1 10.3 13.5 1.1 16.1 10.3 0.4 0 0.4 0.4 55 4 54 305 60 0 60 0 -2.3 0 -2 -2.4 11/26/2004 18:40:00 14.3 0.7 16.4 12.2 14.2 0.8 16.1 11.1 0.4 0 0.4 0.4 55 3 56 305 60 0 60 0 -2.3 0 -2 -2.4 11/26/2004 18:50:00 14.1 0.8 16.4 11.1 14 0.9 16.4 10.7 0.4 0 0.4 0.4 55 3 51 305 60 0 60 0 -2.3 0 -2 -2.4 11/26/2004 19:00:00 13.8 0.9 15.6 11.5 13.8 1 15.6 11.1 0.4 0 0.4 0.4 53 3 54 305 60 0 60 0 -2.3 0 -2 -2.4 11/26/2004 19:10:00 12.7 1.1 14.9 9.9 12.5 1.2 14.9 9.5 0.4 0 0.4 0.4 51 4 50 305 60 0 60 0 -2.3 0 -2 -2.4 11/26/2004 19:20:00 13.3 0.7 14.9 11.5 13.2 0.8 14.9 11.1 0.4 0 0.4 0.4 50 3 54 305 60 0 60 0 -2.4 0 -2.2 -2.4 11/26/2004 19:30:00 13.2 0.6 14.5 11.1 13 0.7 14.5 10.7 0.4 0 0.4 0.4 54 4 56 305 60 0 60 0 -2.4 0 -2.4 -2.7 11/26/2004 19:40:00 12.6 1.1 14.9 10.3 12.6 1.2 15.3 9.9 0.4 0 0.4 0.4 58 4 58 305 60 0 60 0 -2.4 0 -2 -2.7 11/26/2004 19:50:00 11.7 1 14.1 9.1 11.6 1.1 13.7 8.8 0.4 0 0.4 0.4 54 5 49 305 61 0 61 0 -2.2 0 -2 -2.4 11/26/2004 20:00:00 12.3 0.8 14.1 9.9 12.2 0.9 14.5 9.1 0.4 0 0.4 0.4 53 3 51 305 61 0 62 0 -2.3 0 -1.8 -2.4 11/26/2004 20:10:00 11.5 1 13.3 9.1 11.4 1.1 13.3 8.8 0.4 0 0.4 0.4 53 4 59 305 61 0 62 0 -2.2 0 -1.8 -2.4 11/26/2004 20:20:00 12.1 1 14.1 9.1 11.9 1 14.1 9.1 0.4 0 0.4 0.4 51 4 46 305 61 0 62 0 -2.3 0 -1.8 -2.4 11/26/2004 20:30:00 12.2 0.9 14.1 9.9 12.1 1 14.1 9.1 0.4 0 0.4 0.4 53 4 53 305 61 0 62 0 -2.2 0 -1.8 -2.4 11/26/2004 20:40:00 11.9 0.8 13.7 9.9 11.8 0.9 14.1 8.8 0.4 0 0.4 0.4 53 4 52 305 61 0 62 0 -2.2 0 -1.8 -2.4 11/26/2004 20:50:00 12.1 0.7 13.3 10.3 12 0.8 13.7 9.1 0.4 0 0.4 0.4 55 4 59 305 61 0 62 0 -2.2 0 -1.8 -2.4 11/26/2004 21:00:00 12.4 0.8 13.7 10.3 12.3 0.9 14.1 9.1 0.4 0 0.4 0.4 51 3 49 305 61 0 62 0 -2.2 0 -2 -2.4 11/26/2004 21:10:00 12.1 0.6 13.3 10.3 12 0.7 13.3 10.3 0.4 0 0.4 0.4 50 3 50 305 61 0 62 0 -2.2 0 -1.8 -2.4 11/26/2004 21:20:00 11.7 0.6 13.3 9.5 11.6 0.7 13.3 9.1 0.4 0 0.4 0.4 50 3 51 305 62 0 62 0 -2.1 0.1 -1.5 -2.2 11/26/2004 21:30:00 11.3 0.8 13 9.1 11.3 0.8 13 9.1 0.4 0 0.4 0.4 51 4 46 305 62 0 62 0 -2 0.1 -1.5 -2.2 11/26/2004 21:40:00 11.7 0.6 13.3 9.9 11.6 0.6 13 9.5 0.4 0 0.4 0.4 50 4 54 305 62 0 62 0 -2 0 -1.5 -2.2 11/26/2004 21:50:00 11.8 0.6 13.3 9.9 11.8 0.6 13.3 10.3 0.4 0 0.4 0.4 52 3 53 305 62 0 62 0 -1.9 0 -1.3 -2 11/26/2004 22:00:00 12.5 0.8 14.1 10.3 12.5 0.9 14.1 9.5 0.4 0 0.4 0.4 51 3 48 305 62 0 62 0 -1.8 0 -1.3 -2 11/26/2004 22:10:00 12.4 0.8 14.1 10.3 12.3 0.8 14.1 9.9 0.4 0 0.4 0.4 51 3 55 305 62 0 62 0 -1.8 0 -1.3 -2 11/26/2004 22:20:00 11.3 0.9 13.3 8.4 11.2 1 13.3 8.8 0.4 0 0.4 0.4 56 4 54 305 62 0 62 0 -1.7 0 -1.3 -2 11/26/2004 22:30:00 11.3 0.9 13.3 8.8 11.3 1 13 8.8 0.4 0 0.4 0.4 55 4 56 305 62 0 62 0 -1.7 0 -1.1 -1.8 11/26/2004 22:40:00 11.7 0.8 13 8.8 11.5 0.9 13.3 8.8 0.4 0 0.4 0.4 53 4 49 305 62 0 62 0 -1.7 0 -1.3 -1.8 11/26/2004 22:50:00 11.7 0.7 13 9.5 11.6 0.7 13 9.5 0.4 0 0.4 0.4 51 5 56 305 62 0 62 0 -1.6 0 -1.3 -1.8 11/26/2004 23:00:00 12 0.8 13.7 9.5 11.9 0.8 13.7 9.5 0.4 0 0.4 0.4 52 4 50 305 62 0 62 0 -1.6 0 -1.1 -1.8 11/26/2004 23:10:00 12.7 0.8 14.5 10.3 12.5 0.9 14.5 9.9 0.4 0 0.4 0.4 55 3 54 305 62 0 62 0 -1.6 0 -1.3 -1.8 11/26/2004 23:20:00 12.2 0.9 13.7 9.5 12 1 14.1 9.5 0.4 0 0.4 0.4 57 3 57 305 62 0 62 0 -1.6 0 -1.1 -1.8 11/26/2004 23:30:00 12.6 0.8 14.1 9.9 12.5 0.8 14.1 10.3 0.4 0 0.4 0.4 51 4 49 305 62 0 62 0 -1.6 0 -1.3 -1.8 11/26/2004 23:40:00 12.5 0.9 14.5 9.5 12.3 1 14.5 9.9 0.4 0 0.4 0.4 53 4 50 305 62 0 62 0 -1.6 0 -1.3 -1.8 11/26/2004 23:50:00 12 1 14.1 9.1 11.8 1.1 14.1 8.4 0.4 0 0.4 0.4 56 4 54 305 61 0 62 0 -1.6 0 -1.3 -1.8 11/27/2004 00:00:00 11.9 0.8 13.7 9.5 11.8 0.9 13.7 8.8 0.4 0 0.4 0.4 60 4 53 305 61 0 62 0 -1.6 0 -1.3 -1.8 11/27/2004 00:10:00 11.9 0.6 13.3 10.7 11.8 0.7 13.3 9.9 0.4 0 0.4 0.4 56 3 54 305 61 0 62 0 -1.5 0 -1.3 -1.8 11/27/2004 00:20:00 11.7 0.8 13.3 9.5 11.6 0.8 13.3 8.8 0.4 0 0.4 0.4 55 3 53 305 61 0 62 0 -1.5 0 -1.3 -1.8 11/27/2004 00:30:00 11.5 1 13.3 8.8 11.3 1.1 13.7 8.4 0.4 0 0.4 0.4 58 4 53 305 61 0 61 0 -1.6 0 -1.3 -1.8 11/27/2004 00:40:00 11.6 0.7 13.3 9.5 11.3 0.9 13 8.8 0.4 0 0.4 0.4 58 4 59 305 61 0 61 0 -1.5 0 -1.3 -1.8 11/27/2004 00:50:00 10.9 1 12.6 8 10.8 1 12.6 8 0.4 0 0.4 0.4 61 5 67 305 61 0 61 0 -1.4 0 -1.3 -1.5 11/27/2004 01:00:00 11.3 1 13 8.8 11.1 1 13.3 8 0.4 0 0.4 0.4 61 5 59 305 61 0 61 0 -1.4 0 -1.3 -1.5 11/27/2004 01:10:00 11.9 0.7 13.3 9.9 11.7 0.8 13.3 9.5 0.4 0 0.4 0.4 54 3 53 305 61 0 61 0 -1.5 0 -1.3 -1.8 11/27/2004 01:20:00 12.6 0.6 14.1 9.9 12.5 0.7 14.1 10.3 0.4 0 0.4 0.4 53 2 54 305 61 0 61 0 -1.7 0 -1.5 -1.8 11/27/2004 01:30:00 12.4 0.7 13.7 10.3 12.3 0.7 14.1 9.9 0.4 0 0.4 0.4 53 4 48 305 61 0 61 0 -1.7 0 -1.5 -1.8 11/27/2004 01:40:00 12.2 0.8 14.1 10.3 12.1 0.9 14.1 9.5 0.4 0 0.4 0.4 53 3 51 305 61 0 61 0 -1.6 0 -1.3 -1.8 11/27/2004 01:50:00 12.1 0.9 13.7 9.9 12 0.9 13.7 9.9 0.4 0 0.4 0.4 54 3 54 305 61 0 61 0 -1.6 0 -1.1 -1.8 11/27/2004 02:00:00 11.6 0.8 13 8.4 11.4 0.8 13 8.8 0.4 0 0.4 0.4 52 4 50 305 61 0 61 0 -1.5 0 -1.1 -1.8 11/27/2004 02:10:00 11.7 0.7 13 9.9 11.6 0.8 13 9.5 0.4 0 0.4 0.4 51 4 56 305 61 0 61 0 -1.5 0 -1.3 -1.8 11/27/2004 02:20:00 11.9 0.6 13.3 9.5 11.8 0.7 13.3 9.5 0.4 0 0.4 0.4 51 3 45 305 61 0 62 0 -1.5 0 -1.3 -1.8 11/27/2004 02:30:00 11.7 0.6 13 9.9 11.6 0.7 13.3 9.1 0.4 0 0.4 0.4 50 3 45 305 61 0 61 0 -1.5 0 -1.3 -1.8 11/27/2004 02:40:00 11.5 0.7 13 9.1 11.4 0.7 13 8.8 0.4 0 0.4 0.4 50 4 50 305 61 0 61 0 -1.5 0 -1.1 -1.8 11/27/2004 02:50:00 11.8 0.6 13 9.9 11.7 0.6 13 9.5 0.4 0 0.4 0.4 50 3 50 305 61 0 61 0 -1.5 0 -1.1 -1.8 11/27/2004 03:00:00 11.8 0.7 13 9.5 11.6 0.8 13.3 9.5 0.4 0 0.4 0.4 46 5 42 305 61 0 61 0 -1.6 0 -1.3 -1.8 11/27/2004 03:10:00 11.8 0.8 13.3 9.1 11.7 1 13.7 9.1 0.4 0 0.4 0.4 45 4 50 305 61 0 61 0 -1.6 0 -1.3 -1.8 11/27/2004 03:20:00 12 0.8 13.3 9.5 11.9 0.8 13.7 9.5 0.4 0 0.4 0.4 46 4 51 305 61 0 61 0 -1.6 0 -1.1 -1.8 11/27/2004 03:30:00 12.3 0.7 13.7 10.3 12.2 0.9 14.1 9.1 0.4 0 0.4 0.4 42 3 46 305 61 0 61 0 -1.7 0 -1.3 -1.8 11/27/2004 03:40:00 12.2 0.6 13.3 10.3 12.1 0.7 13.7 9.1 0.4 0 0.4 0.4 44 3 51 305 60 0 60 0 -1.7 0 -1.3 -1.8 11/27/2004 03:50:00 11.7 0.8 13.7 9.5 11.6 0.8 13.3 9.1 0.4 0 0.4 0.4 45 4 39 305 60 0 60 0 -1.6 0 -1.3 -1.8 11/27/2004 04:00:00 11.9 0.7 13.3 9.5 11.8 0.8 13.3 9.1 0.4 0 0.4 0.4 43 3 40 305 60 0 60 0 -1.7 0 -1.3 -1.8 11/27/2004 04:10:00 11.8 0.6 13.3 9.5 11.8 0.7 13.7 9.5 0.4 0 0.4 0.4 44 4 46 305 60 0 60 0 -1.7 0 -1.3 -1.8 11/27/2004 04:20:00 11.8 0.7 13.3 9.5 11.7 0.8 13.7 8.8 0.4 0 0.4 0.4 45 4 45 305 60 0 60 0 -1.7 0 -1.5 -1.8 11/27/2004 04:30:00 11.9 0.6 13.3 9.9 11.8 0.7 13.3 9.9 0.4 0 0.4 0.4 42 4 45 305 60 0 60 0 -1.7 0 -1.5 -1.8 11/27/2004 04:40:00 11.5 0.8 13.3 9.5 11.4 1 13.3 9.1 0.4 0 0.4 0.4 44 4 41 305 60 0 60 0 -1.6 0 -1.5 -1.8 11/27/2004 04:50:00 12 0.8 13.7 9.5 11.9 0.8 13.7 9.5 0.4 0 0.4 0.4 46 4 49 305 59 0 59 0 -1.6 0 -1.3 -1.8 11/27/2004 05:00:00 12.6 0.8 14.1 10.3 12.6 0.8 14.1 9.9 0.4 0 0.4 0.4 41 3 39 305 59 0 59 0 -1.7 0 -1.5 -1.8 11/27/2004 05:10:00 12.3 0.8 13.7 9.9 12.1 0.9 14.1 9.5 0.4 0 0.4 0.4 47 4 48 305 59 0 59 0 -1.6 0 -1.3 -1.8 11/27/2004 05:20:00 12.5 0.7 14.1 10.7 12.4 0.8 14.5 10.3 0.4 0 0.4 0.4 44 3 46 305 58 0 58 0 -1.7 0 -1.3 -1.8 11/27/2004 05:30:00 12.6 0.7 14.1 10.3 12.5 0.8 14.1 10.3 0.4 0 0.4 0.4 38 4 42 305 58 0 58 0 -1.7 0 -1.8 -1.8 11/27/2004 05:40:00 12 0.8 13.7 9.9 11.9 0.8 13.7 9.5 0.4 0 0.4 0.4 41 4 43 305 58 0 58 0 -1.7 0 -1.3 -1.8 11/27/2004 05:50:00 11.5 1 14.5 9.1 11.4 1.1 14.1 8.4 0.4 0 0.4 0.4 43 5 49 305 57 0 57 0 -1.8 0 -1.3 -2 11/27/2004 06:00:00 11.3 0.7 13.3 9.1 11.3 0.8 13.3 9.1 0.4 0 0.4 0.4 41 5 44 305 57 0 57 0 -1.7 0 -1.3 -2 11/27/2004 06:10:00 11.8 0.9 14.1 9.5 11.8 1 14.1 9.5 0.4 0 0.4 0.4 46 5 41 305 57 0 57 0 -1.8 0 -1.3 -2 11/27/2004 06:20:00 12.3 0.9 14.1 9.5 12.2 1 14.1 8.8 0.4 0 0.4 0.4 47 6 51 305 56 0 56 0 -1.9 0 -1.5 -2 11/27/2004 06:30:00 12.3 0.7 14.1 10.3 12.3 0.8 14.1 10.3 0.4 0 0.4 0.4 39 5 42 305 56 0 56 0 -1.8 0 -1.5 -2 11/27/2004 06:40:00 12.5 0.8 14.1 9.5 12.3 0.8 14.1 9.9 0.4 0 0.4 0.4 45 4 41 305 56 0 55 0 -1.9 0 -1.8 -2 11/27/2004 06:50:00 12.3 0.8 14.1 9.9 12.2 0.8 13.7 9.9 0.4 0 0.4 0.4 40 5 29 305 55 0 55 0 -2 0 -1.5 -2 11/27/2004 07:00:00 12.3 1.1 14.9 9.9 12.2 1.1 14.5 9.1 0.4 0 0.4 0.4 35 5 31 305 54 0 54 0 -2 0 -1.8 -2.2 11/27/2004 07:10:00 13.1 0.8 14.9 11.1 13.1 0.9 14.9 10.3 0.4 0 0.4 0.4 33 4 30 305 54 0 54 0 -2.2 0 -1.8 -2.2 11/27/2004 07:20:00 12.6 1 14.9 9.5 12.5 1 15.3 10.3 0.4 0 0.4 0.4 33 5 32 305 53 0 53 0 -2.2 0 -1.8 -2.4 11/27/2004 07:30:00 12.9 1 14.5 9.9 12.9 1 14.9 10.3 0.4 0 0.4 0.4 41 6 32 305 53 0 53 0 -2.3 0 -2 -2.4 11/27/2004 07:40:00 12.8 0.8 14.9 10.7 12.8 0.8 14.9 10.7 0.4 0 0.4 0.4 35 4 35 305 53 0 53 0 -2.4 0 -2 -2.7 11/27/2004 07:50:00 12.3 1 14.5 9.5 12.2 1 14.1 9.5 0.4 0 0.4 0.4 37 5 36 305 53 0 53 0 -2.3 0 -2.2 -2.4 11/27/2004 08:00:00 12.5 1 14.9 9.5 12.4 1 15.3 9.5 0.4 0 0.4 0.4 31 4 31 305 52 0 52 0 -2.5 0 -2 -2.7 11/27/2004 08:10:00 12.3 0.8 14.1 10.3 12.3 0.9 14.1 9.5 0.4 0 0.4 0.4 33 3 31 305 52 0 52 0 -2.5 0 -2 -2.7 11/27/2004 08:20:00 12.3 1 14.9 9.9 12.3 1 14.5 9.9 0.4 0 0.4 0.4 34 4 33 305 53 0 53 0 -2.4 0 -2.2 -2.7 11/27/2004 08:30:00 12.4 0.9 14.9 10.3 12.4 1 14.5 9.5 0.4 0 0.4 0.4 39 5 34 305 53 0 53 0 -2.4 0 -2 -2.7 11/27/2004 08:40:00 12.4 1 14.1 9.5 12.4 1.1 14.5 9.9 0.4 0 0.4 0.4 38 4 37 305 53 0 53 0 -2.3 0 -2 -2.4 11/27/2004 08:50:00 12.9 0.9 14.9 9.9 12.8 0.9 15.3 9.9 0.4 0 0.4 0.4 35 5 43 305 53 0 53 0 -2.1 0 -2 -2.2 11/27/2004 09:00:00 11.8 1.1 14.9 9.5 11.7 1.1 15.3 9.1 0.4 0 0.4 0.4 31 5 35 305 53 0 53 0 -2 0 -1.5 -2.2 11/27/2004 09:10:00 12.6 1 15.3 9.5 12.6 1.1 14.9 9.5 0.4 0 0.4 0.4 29 4 32 305 54 0 54 0 -2 0 -1.5 -2.2 11/27/2004 09:20:00 13.2 0.8 15.3 11.1 13.3 0.9 15.6 11.1 0.4 0 0.4 0.4 31 5 33 305 54 0 54 0 -1.9 0 -1.3 -2 11/27/2004 09:30:00 12.8 1 15.3 10.7 12.8 1.1 15.6 10.3 0.4 0 0.4 0.4 26 4 22 305 55 0 54 0 -1.9 0 -1.5 -2 11/27/2004 09:40:00 13.2 1 15.6 10.3 13.1 1.1 16.1 10.3 0.4 0 0.4 0.4 28 4 25 305 55 0 55 0 -1.9 0 -1.5 -2 11/27/2004 09:50:00 13.4 1.1 16.4 10.7 13.4 1.2 16.1 9.9 0.4 0 0.4 0.4 29 5 30 305 55 0 55 0 -2 0 -1.8 -2.2 11/27/2004 10:00:00 13.5 1.3 16.8 9.9 13.3 1.3 16.8 10.3 0.4 0 0.4 0.4 28 5 22 305 55 0 55 0 -2 0 -1.8 -2.2 11/27/2004 10:10:00 13 1.1 16.4 10.7 13 1.1 16.8 10.7 0.4 0 0.4 0.4 29 5 27 305 55 0 55 0 -2 0 -1.8 -2 11/27/2004 10:20:00 13.6 1.1 16.1 11.5 13.6 1.1 16.1 11.1 0.4 0 0.4 0.4 29 4 32 305 55 0 55 0 -1.9 0 -1.8 -2 11/27/2004 10:30:00 13.7 1.2 16.4 10.7 13.7 1.2 16.4 10.3 0.4 0 0.4 0.4 32 3 33 305 55 0 55 0 -1.8 0 -1.8 -2 11/27/2004 10:40:00 14 1 16.4 11.5 13.9 1 16.1 11.1 0.4 0 0.4 0.4 30 4 29 305 55 0 55 0 -1.8 0 -1.8 -2 11/27/2004 10:50:00 14.1 0.9 16.4 12.2 14 1 16.8 11.5 0.4 0 0.4 0.4 28 3 23 305 55 0 55 0 -1.7 0 -1.3 -2 11/27/2004 11:00:00 14.3 1 16.8 11.5 14.2 1.1 16.4 11.5 0.4 0 0.4 0.4 29 3 28 305 55 0 55 0 -1.7 0 -1.8 -1.8 11/27/2004 11:10:00 14 1.1 16.8 11.1 13.9 1.1 16.8 11.1 0.4 0 0.4 0.4 29 4 24 305 55 0 55 0 -1.7 0 -1.3 -1.8 11/27/2004 11:20:00 14.2 1 16.4 11.8 14 1 16.4 11.5 0.4 0 0.4 0.4 30 4 31 305 55 0 55 0 -1.7 0 -1.3 -1.8 11/27/2004 11:30:00 14 1 16.1 10.7 13.9 1.1 16.4 11.1 0.4 0 0.4 0.4 27 4 30 305 56 0 56 0 -1.7 0 -1.3 -1.8 11/27/2004 11:40:00 13.4 1.1 16.1 11.1 13.3 1.2 16.4 9.9 0.4 0 0.4 0.4 26 4 28 305 56 0 56 0 -1.5 0 -1.1 -1.8 11/27/2004 11:50:00 14.3 1 16.4 11.1 14.2 1 16.8 11.1 0.4 0 0.4 0.4 26 4 25 305 57 0 57 0 -1.5 0 -1.1 -1.8 11/27/2004 12:00:00 14 1.3 16.4 11.1 13.9 1.3 17.2 10.7 0.4 0 0.4 0.4 25 4 21 305 58 0 58 0 -1.4 0 -1.1 -1.5 11/27/2004 12:10:00 14.3 1.1 16.8 10.3 14.2 1.2 16.8 9.9 0.4 0 0.4 0.4 25 3 29 305 58 0 58 0 -1.3 0 -1.1 -1.3 11/27/2004 12:20:00 13.8 1 15.6 11.1 13.7 1 16.1 11.1 0.4 0 0.4 0.4 26 4 27 305 58 0 57 0 -1.3 0 -0.8 -1.3 11/27/2004 12:30:00 13.8 1 16.1 11.1 13.7 1 16.4 11.1 0.4 0 0.4 0.4 27 4 30 305 58 0 58 0 -1.2 0 -0.8 -1.3 11/27/2004 12:40:00 13.9 1.2 16.4 11.5 13.8 1.3 16.8 11.1 0.4 0 0.4 0.4 25 3 24 305 59 0 58 0 -1.1 0 -1.1 -1.3 11/27/2004 12:50:00 13.7 1.1 16.4 11.1 13.7 1.2 16.4 10.7 0.4 0 0.4 0.4 25 3 28 305 59 0 59 0 -1.1 0 -0.8 -1.3 11/27/2004 13:00:00 14.5 0.9 16.8 11.8 14.5 1 17.2 11.8 0.4 0 0.4 0.4 25 3 23 305 59 0 59 0 -1.1 0 -0.6 -1.3 11/27/2004 13:10:00 13.9 1.2 16.4 11.1 13.8 1.2 16.4 11.1 0.4 0 0.4 0.4 24 4 23 305 59 0 59 0 -1.1 0 -1.1 -1.3 11/27/2004 13:20:00 14.2 1.1 16.8 10.7 14.1 1.2 16.8 10.7 0.4 0 0.4 0.4 24 4 27 305 59 0 59 0 -1.1 0 -0.6 -1.1 11/27/2004 13:30:00 14.7 1.1 16.8 11.1 14.6 1.1 16.8 10.7 0.4 0 0.4 0.4 22 3 24 305 59 0 58 0 -1.1 0 -1.1 -1.3 11/27/2004 13:40:00 14.2 1 16.4 11.5 14.1 1 16.4 11.1 0.4 0 0.4 0.4 24 3 24 305 59 0 58 0 -1.4 0 -1.1 -1.5 11/27/2004 13:50:00 14.4 1 16.8 11.5 14.4 1 16.8 12.2 0.4 0 0.4 0.4 22 3 24 305 61 1 61 0 -1.4 0 -1.3 -1.5 11/27/2004 14:00:00 14.3 0.8 16.4 11.1 14.2 1 16.8 11.1 0.4 0 0.4 0.4 21 3 24 305 63 1 62 0 -1.4 0 -1.1 -1.3 11/27/2004 14:10:00 13.9 0.9 16.1 11.1 13.9 1 16.1 11.1 0.4 0 0.7 0.4 21 3 17 305 63 0 63 0 -1.2 0 -0.8 -1.3 11/27/2004 14:20:00 13.7 1.1 15.6 10.7 13.7 1.1 16.1 10.7 0.4 0 0.4 0.4 20 4 23 305 63 0 64 0 -1.2 0 -0.6 -1.3 11/27/2004 14:30:00 14.1 1 16.1 11.1 14 1.1 16.4 11.5 0.4 0 0.4 0.4 18 3 18 305 63 0 63 0 -1.2 0 -1.1 -1.3 11/27/2004 14:40:00 13.7 1.1 16.1 10.3 13.7 1.2 16.8 10.7 0.4 0 0.4 0.4 19 3 17 305 63 0 63 0 -1.2 0 -0.8 -1.3 11/27/2004 14:50:00 14.2 1 16.4 11.8 14.1 1.1 16.4 11.5 0.4 0 0.4 0.4 20 3 17 305 63 0 63 0 -1.2 0 -0.8 -1.3 11/27/2004 15:00:00 13.9 1 16.1 11.5 13.8 1 16.4 11.5 0.4 0 0.4 0.4 20 3 23 305 63 0 63 0 -1.2 0 -1.1 -1.3 11/27/2004 15:10:00 14 1.1 16.8 11.5 14 1.2 16.4 11.5 0.4 0 0.4 0.4 19 3 23 305 63 0 63 0 -1.2 0 -1.1 -1.3 11/27/2004 15:20:00 14.3 0.9 16.1 11.5 14.2 1 16.4 11.5 0.4 0 0.4 0.4 20 3 21 305 63 0 63 0 -1.2 0 -1.1 -1.3 11/27/2004 15:30:00 13.6 1 16.1 10.7 13.6 1.1 16.1 10.7 0.4 0 0.4 0.4 20 3 18 305 63 0 63 0 -1.2 0 -0.8 -1.3 11/27/2004 15:40:00 13.8 1 15.6 10.7 13.7 1.1 15.6 10.7 0.4 0 0.4 0.4 21 3 20 305 63 0 63 0 -1.2 0 -1.1 -1.3 11/27/2004 15:50:00 13.3 1 15.6 10.7 13.2 1.1 16.1 10.3 0.4 0 0.4 0.4 22 3 26 305 62 0 63 0 -1.2 0 -1.1 -1.3 11/27/2004 16:00:00 14 1 16.1 11.8 13.9 1.1 16.4 11.1 0.4 0 0.4 0.4 23 3 19 305 62 0 62 0 -1.2 0 -0.8 -1.3 11/27/2004 16:10:00 13.7 0.8 16.1 11.5 13.7 0.9 15.6 11.5 0.4 0 0.4 0.4 23 4 22 305 62 0 63 0 -1.2 0 -0.8 -1.3 11/27/2004 16:20:00 13.5 1 15.6 10.7 13.5 1 16.4 11.1 0.4 0 0.4 0.4 19 3 21 305 62 0 63 0 -1.2 0 -0.8 -1.3 11/27/2004 16:30:00 13 1 15.6 11.1 13 1.1 16.1 10.3 0.4 0 0.4 0.4 18 3 17 305 62 0 62 0 -1.2 0 -1.1 -1.3 11/27/2004 16:40:00 13.4 0.9 15.6 10.7 13.4 1 16.1 10.3 0.4 0 0.4 0.4 17 4 17 305 62 0 62 0 -1.2 0 -0.8 -1.3 11/27/2004 16:50:00 13.4 1 15.6 10.7 13.5 1 15.6 10.3 0.4 0 0.4 0.4 16 3 17 305 62 0 62 0 -1.1 0 -0.6 -1.3 11/27/2004 17:00:00 13.3 1 15.6 10.7 13.2 1.1 15.6 10.3 0.4 0 0.4 0.4 17 3 21 305 62 0 62 0 -1.1 0 -1.1 -1.3 11/27/2004 17:10:00 13.5 1.2 17.2 10.3 13.5 1.3 17.2 10.3 0.4 0 0.4 0.4 17 3 21 305 61 0 61 0 -1.1 0 -0.6 -1.3 11/27/2004 17:20:00 12.7 1 14.9 10.3 12.7 1.1 14.9 9.9 0.4 0 0.4 0.4 16 3 18 305 62 0 62 0 -1.1 0 -0.6 -1.1 11/27/2004 17:30:00 13.5 0.8 15.3 11.5 13.6 0.9 15.6 11.1 0.4 0 0.4 0.4 16 3 13 305 63 0 63 0 -1.1 0 -1.1 -1.1 11/27/2004 17:40:00 12.7 1 15.3 10.3 12.8 1 15.3 9.9 0.4 0 0.4 0.4 15 3 12 305 63 0 63 0 -1 0 -0.8 -1.1 11/27/2004 17:50:00 13.2 0.8 14.9 10.7 13.3 0.9 15.3 10.3 0.4 0 0.4 0.4 16 3 19 305 63 0 63 0 -1 0 -0.8 -1.1 11/27/2004 18:00:00 13.2 0.8 14.5 10.7 13.3 0.8 15.3 10.7 0.4 0 0.4 0.4 13 3 15 305 63 0 63 0 -1 0 -0.8 -1.1 11/27/2004 18:10:00 12.9 0.8 14.5 10.3 13.1 0.8 14.5 10.7 0.4 0 0.4 0.4 14 3 14 305 62 0 62 0 -1 0 -0.6 -1.1 11/27/2004 18:20:00 13 0.8 15.3 11.1 13.1 0.8 14.9 11.1 0.4 0 0.4 0.4 13 3 12 305 62 0 62 0 -0.9 0 -0.4 -1.1 11/27/2004 18:30:00 12.9 1 15.3 10.3 13 1 15.6 11.1 0.4 0 0.4 0.4 13 3 17 305 62 0 62 0 -0.9 0 -0.6 -1.1 11/27/2004 18:40:00 11.8 0.8 13.7 9.5 11.9 0.8 14.1 9.5 0.4 0 0.4 0.4 11 3 13 305 62 0 62 0 -0.8 0 -0.6 -1.1 11/27/2004 18:50:00 12.2 1 14.5 9.9 12.2 1 14.5 9.5 0.4 0 0.4 0.4 10 3 11 305 63 1 62 0 -0.9 0 -0.4 -1.1 11/27/2004 19:00:00 12 0.9 14.1 9.5 12.1 1 14.1 9.5 0.4 0 0.4 0.4 13 3 10 305 64 0 64 0 -0.8 0 -0.4 -1.1 11/27/2004 19:10:00 11.8 0.7 13.7 9.5 11.9 0.8 13.7 9.9 0.4 0 0.4 0.4 13 3 13 305 64 0 64 0 -0.8 0 -0.4 -1.1 11/27/2004 19:20:00 11.3 0.9 13.3 9.1 11.3 1 13.3 8.8 0.4 0 0.4 0.4 13 3 13 305 64 0 64 0 -0.8 0 -0.6 -0.8 11/27/2004 19:30:00 10.6 0.7 12.6 8.8 10.8 0.7 12.2 8.8 0.4 0 0.4 0.4 12 3 12 305 64 0 64 0 -0.7 0 -0.4 -0.8 11/27/2004 19:40:00 11.4 0.9 13.7 9.1 11.4 1 13.3 9.1 0.4 0 0.4 0.4 18 4 15 305 64 0 65 0 -0.8 0 -0.6 -1.1 11/27/2004 19:50:00 11.9 0.9 13.3 9.5 11.9 0.9 13.7 9.5 0.4 0 0.4 0.4 15 4 30 305 65 0 65 0 -1 0 -0.6 -1.1 11/27/2004 20:00:00 10.9 0.8 12.6 8.8 11 0.8 12.6 9.1 0.4 0 0.4 0.4 10 4 11 305 65 0 63 0 -1 0 -0.6 -1.1 11/27/2004 20:10:00 11.4 0.8 13.3 9.5 11.4 0.9 14.1 9.1 0.4 0 0.4 0.4 11 3 9 305 65 0 65 0 -1.1 0 -1.1 -1.3 11/27/2004 20:20:00 11.3 1 13.3 8.8 11.4 1.1 14.1 9.1 0.4 0 0.4 0.4 10 3 9 305 64 0 64 0 -1.3 0 -1.1 -1.5 11/27/2004 20:30:00 11 0.8 12.6 8.8 11.1 0.9 13 8.8 0.4 0 0.4 0.4 9 3 7 305 64 0 65 0 -1.4 0 -1.1 -1.5 11/27/2004 20:40:00 10.4 0.6 12.2 8.8 10.5 0.7 11.8 8.4 0.4 0 0.4 0.4 13 3 9 305 64 0 64 0 -1.3 0 -1.1 -1.3 11/27/2004 20:50:00 9.7 0.6 11.1 8 9.8 0.7 11.1 8 0.4 0 0.4 0.4 14 4 17 305 64 0 64 0 -1.4 0 -1.1 -1.5 11/27/2004 21:00:00 9.4 0.8 11.1 7.2 9.6 0.8 11.5 7.2 0.4 0 0.4 0.4 10 3 11 305 64 0 64 0 -1.4 0 -1.1 -1.5 11/27/2004 21:10:00 8.8 0.8 10.7 6.8 9 0.8 10.7 6.8 0.4 0 0.4 0.4 8 3 5 305 64 0 65 0 -1.4 0 -1.1 -1.5 11/27/2004 21:20:00 9.7 0.8 11.5 7.2 9.9 0.9 11.8 7.2 0.4 0 0.4 0.4 5 3 7 305 65 0 65 0 -1.4 0 -1.3 -1.5 11/27/2004 21:30:00 9 0.9 10.7 6.5 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 7 3 5 305 64 0 65 0 -1.5 0 -1.1 -1.8 11/27/2004 21:40:00 8.7 0.7 10.7 6.8 8.9 0.7 10.7 6.8 0.4 0 0.4 0.4 2 3 359 305 65 0 65 0 -1.4 0 -1.3 -1.8 11/27/2004 21:50:00 8.9 0.7 10.7 7.2 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 3 3 2 305 65 0 65 0 -1.5 0 -1.1 -1.8 11/27/2004 22:00:00 9.1 0.6 10.3 7.2 9.3 0.6 10.7 8 0.4 0 0.4 0.4 1 3 3 305 65 0 63 0 -1.4 0 -1.3 -1.5 11/27/2004 22:10:00 8.4 0.8 9.9 6.1 8.6 0.8 10.3 6.5 0.4 0 0.4 0.4 1 3 1 305 65 0 65 0 -1.5 0 -1.1 -1.8 11/27/2004 22:20:00 8.1 0.6 9.1 6.5 8.2 0.7 9.5 6.5 0.4 0 0.4 0.4 357 3 357 305 65 0 65 0 -1.5 0.1 -1.1 -1.8 11/27/2004 22:30:00 7.7 0.6 8.8 6.1 7.9 0.7 9.1 5.7 0.4 0 0.4 0.4 355 3 355 305 65 0 65 0 -1.6 0 -1.3 -1.8 11/27/2004 22:40:00 7.5 0.6 8.8 5.7 7.7 0.6 8.8 6.1 0.4 0 0.4 0.4 355 3 358 305 65 0 65 0 -1.6 0 -1.3 -1.8 11/27/2004 22:50:00 7.7 0.6 9.1 5.3 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 357 3 0 305 65 0 65 0 -1.7 0 -1.3 -2 11/27/2004 23:00:00 7.4 0.4 8 6.1 7.7 0.4 8.4 6.5 0.4 0 0.4 0.4 356 4 356 305 65 0 65 0 -1.8 0 -1.8 -2 11/27/2004 23:10:00 6.9 0.5 8 5.3 7.2 0.6 8.4 5.7 0.4 0 0.4 0.4 355 3 353 305 65 0 65 0 -1.8 0 -1.8 -2 11/27/2004 23:20:00 7.5 0.5 8.4 6.1 7.7 0.5 8.8 6.1 0.4 0 0.4 0.4 356 3 350 305 65 0 65 0 -2 0 -1.8 -2 11/27/2004 23:30:00 6.9 0.6 8 5.3 7.2 0.6 8.4 5.7 0.4 0 0.4 0.4 352 3 351 305 65 0 65 0 -1.9 0 -1.8 -2 11/27/2004 23:40:00 7 0.6 8 5.3 7.3 0.7 8.4 5.3 0.4 0 0.4 0.4 348 4 347 305 65 0 65 0 -1.9 0 -1.3 -2 11/27/2004 23:50:00 7.3 0.4 8.4 6.1 7.5 0.5 8.4 6.5 0.4 0 0.4 0.4 343 4 339 305 65 0 65 0 -1.8 0 -1.5 -2 11/28/2004 00:00:00 7 0.6 8 5.3 7.3 0.6 8.4 6.1 0.4 0 0.4 0.4 344 3 344 305 65 0 65 0 -1.8 0 -1.3 -2 11/28/2004 00:10:00 7.4 0.5 8.4 5.7 7.7 0.5 9.1 5.7 0.4 0 0.4 0.4 344 3 341 305 65 0 65 0 -1.8 0 -1.8 -2 11/28/2004 00:20:00 6.6 0.5 7.6 4.9 6.9 0.5 8 5.3 0.4 0 0.4 0.4 348 3 347 305 65 0 65 0 -1.8 0 -1.8 -2 11/28/2004 00:30:00 6.4 0.5 7.6 4.9 6.7 0.5 8 5.3 0.4 0 0.4 0.4 349 3 350 305 65 0 65 0 -1.7 0 -1.8 -1.8 11/28/2004 00:40:00 6.8 0.5 8.4 5.3 7.1 0.5 8.8 5.7 0.4 0 0.4 0.4 345 4 344 305 65 1 65 0 -1.7 0 -1.8 -1.8 11/28/2004 00:50:00 6.9 0.5 8 5.7 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 342 5 343 305 67 0 67 0 -1.7 0 -1.8 -1.8 11/28/2004 01:00:00 6.3 0.7 7.6 4.2 6.5 0.7 8 4.2 0.4 0 0.4 0.4 335 4 332 305 67 0 67 0 -1.7 0 -1.8 -1.8 11/28/2004 01:10:00 5.6 0.6 6.8 4.2 5.8 0.7 7.2 4.6 0.4 0 0.4 0.4 339 8 347 305 67 0 68 0 -1.7 0 -1.5 -1.8 11/28/2004 01:20:00 5.8 0.5 6.8 4.2 6 0.5 7.2 4.6 0.4 0 0.4 0.4 326 6 327 305 68 0 68 0 -1.6 0 -1.5 -1.8 11/28/2004 01:30:00 4.8 0.8 6.1 2.6 5 0.8 6.5 3 0.4 0 0.4 0.4 329 6 331 305 68 0 68 0 -1.6 0 -1.5 -1.8 11/28/2004 01:40:00 5.8 0.4 6.8 4.6 6 0.4 6.8 4.9 0.4 0 0.4 0.4 327 4 330 305 68 0 68 0 -1.6 0 -1.5 -1.8 11/28/2004 01:50:00 6.6 0.4 7.2 5.3 6.8 0.4 7.6 5.7 0.4 0 0.4 0.4 317 5 318 305 68 0 68 0 -1.8 0 -1.5 -2 11/28/2004 02:00:00 5.3 1 6.8 3 5.4 0.8 6.8 3.4 0.4 0 0.4 0.4 317 13 305 305 68 1 68 0 -1.8 0 -1.8 -2 11/28/2004 02:10:00 4.8 1.6 7.6 1.9 5 1.5 7.6 1.9 0.4 0 0.4 0.4 330 9 317 305 68 0 68 0 -1.7 0 -1.8 -1.8 11/28/2004 02:20:00 6.1 0.6 7.2 4.2 6.2 0.5 7.2 4.6 0.4 0 0.4 0.4 316 6 323 305 69 0 68 0 -1.6 0 -1.5 -1.8 11/28/2004 02:30:00 5.9 0.7 7.2 4.2 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 324 5 323 305 69 0 69 0 -1.5 0 -1.3 -1.8 11/28/2004 02:40:00 6.3 0.3 6.8 5.3 6.5 0.4 7.2 5.3 0.4 0 0.4 0.4 320 4 320 305 69 0 69 0 -1.5 0 -1.3 -1.8 11/28/2004 02:50:00 6.1 0.6 7.2 4.2 6.2 0.7 7.2 4.2 0.4 0 0.4 0.4 314 5 321 305 69 1 69 0 -1.5 0 -1.3 -1.8 11/28/2004 03:00:00 5.8 0.5 6.8 4.2 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 310 15 310 305 69 1 69 0 -1.5 0.1 -1.1 -1.8 11/28/2004 03:10:00 5.7 0.4 6.5 4.6 5.6 0.5 6.5 4.6 0.4 0 0.4 0.4 309 10 321 305 68 2 69 0 -1.4 0 -1.1 -1.5 11/28/2004 03:20:00 5.2 0.3 6.1 4.2 5.1 0.3 5.7 4.2 0.4 0 0.4 0.4 306 10 305 305 68 2 65 0 -1.4 0 -1.1 -1.3 11/28/2004 03:30:00 5.3 0.3 6.1 4.6 5 0.3 5.7 4.2 0.4 0 0.4 0.4 299 12 303 305 65 1 65 0 -1.4 0 -0.8 -1.3 11/28/2004 03:40:00 4.9 0.3 5.7 3.8 4.4 0.4 5.3 3 0.4 0 0.4 0.4 288 6 288 305 66 0 65 0 -1.4 0 -1.1 -1.5 11/28/2004 03:50:00 4.4 0.5 5.3 2.6 3.5 0.5 4.6 2.3 0.4 0 0.4 0.4 265 8 266 305 66 0 66 0 -1.4 0 -1.1 -1.5 11/28/2004 04:00:00 4.6 0.4 5.7 3.4 4.1 0.5 5.3 2.6 0.4 0 0.4 0.4 249 5 253 305 66 0 66 0 -1.4 0 -1.3 -1.3 11/28/2004 04:10:00 2.8 0.9 4.9 1.1 2.7 0.8 4.6 1.5 0.4 0 0.4 0.4 247 6 251 305 66 0 66 0 -1.2 0 -1.1 -1.3 11/28/2004 04:20:00 1.5 0.4 2.6 0.7 1.7 0.4 3 1.1 0.4 0 0.4 0.4 241 10 220 305 67 0 67 0 -1.1 0 -1.1 -1.3 11/28/2004 04:30:00 3.2 0.4 4.2 2.3 3.6 0.5 4.6 1.9 0.4 0 0.4 0.4 204 9 196 305 67 0 67 0 -1.1 0 -1.1 -1.3 11/28/2004 04:40:00 2.6 0.7 4.2 1.1 3.3 0.7 4.6 1.9 0.4 0 0.4 0.4 187 9 192 305 67 0 67 0 -1.2 0 -1.1 -1.3 11/28/2004 04:50:00 2.3 0.2 2.6 1.9 2.3 0.3 3 1.5 0.4 0 0.4 0.4 222 4 218 305 67 0 67 0 -1.2 0 -1.1 -1.3 11/28/2004 05:00:00 2.3 0.9 4.6 0.4 2.6 0.7 4.6 0.7 0.4 0 0.4 0.4 220 12 205 305 67 0 67 0 -1.3 0 -0.8 -1.3 11/28/2004 05:10:00 3.1 1.5 5.3 0.7 2.8 1.1 4.6 1.1 0.4 0 0.4 0.4 235 5 239 305 66 0 66 0 -1.4 0 -0.8 -1.5 11/28/2004 05:20:00 3.6 0.4 4.6 2.6 3.1 0.4 4.2 1.9 0.4 0 0.4 0.4 235 4 238 305 67 0 66 0 -1.4 0 -1.1 -1.5 11/28/2004 05:30:00 3.1 0.4 4.2 1.9 3 0.4 4.2 2.3 0.4 0 0.4 0.4 234 7 234 305 66 0 67 0 -1.3 0 -0.8 -1.3 11/28/2004 05:40:00 3.5 1.2 6.1 1.1 2.8 0.8 4.9 1.1 0.4 0 0.4 0.4 266 14 271 305 66 0 66 0 -1.2 0 -0.8 -1.3 11/28/2004 05:50:00 4.8 0.3 5.7 3.8 3.4 0.4 4.6 2.3 0.4 0 0.4 0.4 262 3 267 305 66 0 66 0 -1.4 0 -1.1 -1.5 11/28/2004 06:00:00 4.1 0.5 4.9 2.3 3.6 0.7 4.9 1.9 0.4 0 0.4 0.4 252 5 252 305 66 0 66 0 -1.4 0 -1.1 -1.5 11/28/2004 06:10:00 4.4 0.4 5.3 3.4 3.7 0.5 4.9 2.3 0.4 0 0.4 0.4 254 6 252 305 66 0 66 0 -1.5 0 -1.1 -1.8 11/28/2004 06:20:00 4.4 0.5 5.3 3 3.6 0.6 4.9 1.9 0.4 0 0.4 0.4 255 5 258 305 66 0 66 0 -1.6 0 -1.1 -1.8 11/28/2004 06:30:00 4.3 0.6 5.3 3 3.7 0.6 4.9 2.3 0.4 0 0.4 0.4 251 5 256 305 66 0 66 0 -1.6 0 -1.3 -1.8 11/28/2004 06:40:00 3.5 0.4 4.2 2.3 3 0.4 4.2 1.9 0.4 0 0.4 0.4 248 5 258 305 66 0 66 0 -1.6 0 -1.3 -1.8 11/28/2004 06:50:00 3.4 0.4 4.2 2.3 3 0.4 3.8 1.9 0.4 0 0.4 0.4 243 5 246 305 66 0 66 0 -1.7 0 -1.3 -1.8 11/28/2004 07:00:00 3.6 0.3 4.2 2.6 3.4 0.3 4.2 2.3 0.4 0 0.4 0.4 231 5 237 305 66 0 66 0 -1.6 0 -1.1 -1.8 11/28/2004 07:10:00 3.2 0.3 3.8 2.3 3 0.3 3.8 2.3 0.4 0 0.4 0.4 225 4 232 305 66 0 66 0 -1.6 0 -1.1 -1.8 11/28/2004 07:20:00 3.3 0.3 4.2 2.3 3.2 0.4 3.8 2.3 0.4 0 0.4 0.4 227 2 224 305 66 0 66 0 -1.7 0 -1.3 -1.8 11/28/2004 07:30:00 2.7 0.4 3.4 1.9 2.7 0.5 3.4 1.5 0.4 0 0.4 0.4 222 3 227 305 66 0 66 0 -1.6 0 -1.3 -1.8 11/28/2004 07:40:00 2.6 0.3 3.4 1.9 2.6 0.4 3.4 1.5 0.4 0 0.4 0.4 218 7 227 305 66 0 66 0 -1.6 0 -1.1 -1.8 11/28/2004 07:50:00 3.2 0.3 3.8 1.9 3.2 0.4 3.8 2.3 0.4 0 0.4 0.4 220 3 215 305 66 0 66 0 -1.6 0 -1.3 -1.8 11/28/2004 08:00:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 0.4 0 0.4 0.4 214 6 215 305 66 0 66 0 -1.6 0 -1.5 -1.8 11/28/2004 08:10:00 2.2 0.4 3 0.7 2.6 0.3 3.4 1.9 0.4 0 0.4 0.4 192 11 205 305 66 0 66 0 -1.9 0.1 -1.8 -2 11/28/2004 08:20:00 1.1 0.5 2.3 0.4 2.1 0.3 3 1.5 0.4 0 0.4 0.4 173 5 188 305 67 0 67 0 -2 0 -1.8 -2 11/28/2004 08:30:00 1 0.5 1.9 0.4 1.7 0.3 2.3 1.1 0.4 0 0.4 0.4 183 10 179 305 66 0 67 0 -1.9 0 -1.8 -2 11/28/2004 08:40:00 0.4 0 0.7 0.4 0.9 0.4 1.5 0.4 0.4 0 0.4 0.4 196 0 196 305 66 0 66 0 -1.8 0 -1.8 -2 11/28/2004 08:50:00 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 187 13 305 305 66 0 66 0 -1.9 0 -1.8 -2 11/28/2004 09:00:00 1 0.5 1.9 0.4 1.6 0.3 2.3 0.7 0.4 0 0.4 0.4 145 13 149 305 67 0 67 0 -2 0.1 -1.8 -2.2 11/28/2004 09:10:00 1 0.4 2.3 0.4 1.8 0.3 2.6 1.1 0.4 0 0.4 0.4 155 10 150 305 67 0 67 0 -2 0.1 -1.8 -2.2 11/28/2004 09:20:00 1.4 0.4 2.3 0.4 2.4 0.4 3 1.1 0.4 0 0.4 0.4 169 8 157 305 67 0 67 0 -2 0.1 -1.8 -2.2 11/28/2004 09:30:00 1.3 0.5 2.6 0.4 2.3 0.3 3 1.5 0.4 0 0.4 0.4 178 3 181 305 66 0 66 0 -2.2 0 -1.8 -2.2 11/28/2004 09:40:00 0.7 0.4 2.3 0.4 2.1 0.2 2.6 1.5 0.4 0 0.4 0.4 172 6 150 305 66 0 66 0 -2.3 0 -1.8 -2.4 11/28/2004 09:50:00 1.5 0.5 3 0.4 2.3 0.3 3 1.5 0.4 0 0.4 0.4 160 5 154 305 66 0 66 0 -2.3 0 -2 -2.4 11/28/2004 10:00:00 1.5 0.5 2.6 0.4 2.5 0.3 3 1.9 0.4 0 0.4 0.4 175 8 160 305 66 0 65 0 -2.6 0.1 -2.4 -2.9 11/28/2004 10:10:00 1.3 0.4 2.3 0.4 2.4 0.3 3 1.9 0.4 0 0.4 0.4 165 7 159 305 65 0 65 0 -3.1 0.2 -2.7 -3.3 11/28/2004 10:20:00 1.8 0.5 3 0.4 2.7 0.4 3.4 1.5 0.4 0 0.4 0.4 177 6 182 305 64 0 64 0 -3.4 0 -3.3 -3.8 11/28/2004 10:30:00 2.3 0.3 3 1.1 2.9 0.2 3.4 2.3 0.4 0 0.4 0.4 183 2 184 305 64 0 64 0 -3.3 0 -3.1 -3.3 11/28/2004 10:40:00 2.4 0.4 3 1.1 2.9 0.2 3.4 2.3 0.4 0 0.4 0.4 184 3 184 305 64 0 64 0 -3.3 0 -3.3 -3.6 11/28/2004 10:50:00 1.8 0.5 2.6 0.7 2.5 0.2 3 1.9 0.4 0 0.4 0.4 181 4 184 305 64 0 64 0 -3.3 0 -3.1 -3.3 11/28/2004 11:00:00 2 0.4 3 0.7 2.7 0.2 3.4 1.9 0.4 0 0.4 0.4 181 4 183 305 65 0 65 0 -3.3 0 -2.9 -3.3 11/28/2004 11:10:00 1.6 0.4 2.6 0.4 2.6 0.3 3 1.9 0.4 0 0.4 0.4 177 4 182 305 65 0 65 0 -3.4 0 -2.9 -3.8 11/28/2004 11:20:00 1.4 0.5 2.3 0.7 2.6 0.2 3 1.9 0.4 0 0.4 0.4 176 6 177 305 64 0 64 0 -3.7 0.1 -3.3 -3.8 11/28/2004 11:30:00 2.3 0.3 3 1.1 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 185 4 186 305 64 0 64 0 -3.3 0.1 -2.7 -3.8 11/28/2004 11:40:00 2.3 0.3 3 1.1 2.8 0.2 3.4 2.3 0.4 0 0.4 0.4 182 2 184 305 64 0 64 0 -3.8 0.1 -3.3 -4 11/28/2004 11:50:00 2.1 0.4 3 1.1 2.7 0.4 3.4 1.9 0.4 0 0.4 0.4 182 1 183 305 63 0 64 0 -3.8 0 -3.3 -3.8 11/28/2004 12:00:00 0.9 0.5 1.9 0.4 1.7 0.4 2.6 0.7 0.4 0 0.4 0.4 177 9 181 305 64 0 64 0 -3.9 0 -3.3 -4 11/28/2004 12:10:00 1.5 0.4 2.3 0.4 2.1 0.4 3 1.1 0.4 0 0.4 0.4 183 7 189 305 64 0 65 0 -3.6 0 -3.1 -3.8 11/28/2004 12:20:00 1.3 0.5 3 0.4 2 0.6 3 0.7 0.4 0 0.4 0.4 174 8 156 305 65 0 65 0 -3.5 0.1 -2.9 -3.8 11/28/2004 12:30:00 0.4 0.2 1.1 0.4 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 173 4 177 305 66 0 65 0 -3.6 0 -3.1 -3.8 11/28/2004 12:40:00 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 173 0 305 305 65 0 65 0 -3.8 0 -3.3 -3.8 11/28/2004 12:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 173 0 305 305 65 0 65 0 -3.6 0 -3.1 -3.8 11/28/2004 13:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 173 0 305 305 66 0 66 0 -3.4 0.1 -2.7 -3.6 11/28/2004 13:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 173 0 305 305 66 0 66 0 -3 0.1 -2.4 -3.3 11/28/2004 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 173 0 305 305 66 0 0 0 -3.5 0.1 -3.1 -3.8 11/28/2004 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 171 6 305 305 66 0 0 0 -3.8 0 -3.3 -3.8 11/28/2004 13:40:00 0.6 0.3 1.1 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 74 22 64 305 66 0 66 0 -3.4 0.3 -2.4 -3.8 11/28/2004 13:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 64 0 64 305 66 0 66 0 -2.9 0 -2.4 -3.1 11/28/2004 14:00:00 0.8 0.6 2.3 0.4 1.4 0.5 2.6 0.4 0.4 0 0.4 0.4 123 32 142 305 66 0 66 0 -2.7 0.1 -2.2 -3.1 11/28/2004 14:10:00 0.8 0.7 3.4 0.4 1.3 0.8 3.4 0.4 0.4 0 0.4 0.4 135 13 135 305 66 0 66 0 -2.6 0.1 -2 -2.7 11/28/2004 14:20:00 0.8 0.8 3 0.4 1.1 0.9 3.4 0.4 0.4 0 0.4 0.4 117 26 113 305 66 0 66 0 -2.4 0.1 -2 -2.7 11/28/2004 14:30:00 0.9 0.5 1.9 0.4 1.2 0.5 2.3 0.4 0.4 0 0.4 0.4 38 15 18 305 67 0 67 0 -2.3 0 -1.8 -2.4 11/28/2004 14:40:00 0.5 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0 0.4 0.4 28 12 54 305 67 0 67 0 -2.2 0 -1.8 -2.4 11/28/2004 14:50:00 1.7 0.6 3 0.4 1.6 0.4 2.6 0.7 0.4 0 0.4 0.4 66 18 48 305 67 0 67 0 -2.2 0 -1.8 -2.4 11/28/2004 15:00:00 2.3 0.5 3.4 1.1 2.3 0.4 3.4 1.1 0.4 0 0.4 0.4 78 18 88 305 67 0 67 0 -2 0.1 -1.3 -2.2 11/28/2004 15:10:00 3.2 0.3 3.8 2.6 3.2 0.2 3.8 2.6 0.4 0 0.4 0.4 103 5 98 305 67 0 67 0 -2.2 0 -1.8 -2.4 11/28/2004 15:20:00 3 0.3 3.4 1.9 2.9 0.3 3.4 1.9 0.4 0 0.4 0.4 107 3 110 305 68 0 67 0 -2 0.1 -1.5 -2.2 11/28/2004 15:30:00 2.5 0.4 3.4 1.5 2.3 0.4 3.4 1.1 0.4 0 0.4 0.4 112 6 104 305 68 0 68 0 -2 0 -1.3 -2 11/28/2004 15:40:00 2 0.3 2.6 1.1 1.6 0.4 2.6 0.7 0.4 0 0.4 0.4 112 6 116 305 68 0 68 0 -2 0 -1.5 -2 11/28/2004 15:50:00 2.5 0.3 3 1.9 2.2 0.4 3 1.5 0.4 0 0.4 0.4 89 8 90 305 68 0 68 0 -2.1 0.1 -1.5 -2.2 11/28/2004 16:00:00 3 0.3 3.8 1.9 3 0.3 3.4 2.3 0.4 0 0.4 0.4 63 5 59 305 67 0 68 0 -1.8 0.1 -1.1 -2 11/28/2004 16:10:00 3.5 0.2 4.2 3 3.4 0.2 4.2 3 0.4 0 0.4 0.4 61 2 58 305 67 0 67 0 -1.6 0 -1.1 -1.8 11/28/2004 16:20:00 3.4 0.2 3.8 3 3.2 0.2 3.8 2.6 0.4 0 0.4 0.4 62 2 63 305 68 0 67 0 -1.6 0.1 -1.1 -1.8 11/28/2004 16:30:00 3.3 0.2 3.8 2.6 3.1 0.2 3.8 2.6 0.4 0 0.4 0.4 66 3 65 305 68 0 67 0 -1.6 0 -1.1 -1.8 11/28/2004 16:40:00 3.2 0.2 3.8 2.6 2.9 0.2 3.8 2.3 0.4 0 0.4 0.4 67 3 72 305 68 0 68 0 -1.6 0 -1.1 -1.8 11/28/2004 16:50:00 3.2 0.2 3.8 2.6 3 0.2 3.4 2.3 0.4 0 0.4 0.4 70 4 74 305 68 0 68 0 -1.6 0 -1.1 -1.8 11/28/2004 17:00:00 3.4 0.3 4.2 2.6 3.1 0.3 3.8 2.6 0.4 0 0.4 0.4 70 3 71 305 68 0 68 0 -1.6 0 -1.5 -1.8 11/28/2004 17:10:00 3.3 0.2 3.8 2.6 3.1 0.2 3.4 2.6 0.4 0 0.4 0.4 75 3 74 305 68 0 67 0 -1.6 0 -1.5 -1.8 11/28/2004 17:20:00 2.8 0.3 3.4 2.3 2.6 0.2 3 1.9 0.4 0 0.4 0.4 73 4 71 305 68 0 67 0 -1.6 0 -1.5 -1.8 11/28/2004 17:30:00 2.6 0.2 3.4 1.9 2.6 0.3 3 1.9 0.4 0 0.4 0.4 54 5 61 305 68 0 68 0 -1.6 0 -1.3 -1.8 11/28/2004 17:40:00 2.4 0.3 3 1.5 2.4 0.2 3 1.9 0.4 0 0.4 0.4 46 4 47 305 68 0 68 0 -1.5 0 -1.3 -1.8 11/28/2004 17:50:00 2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 0.4 0 0.4 0.4 48 2 50 305 68 0 69 0 -1.5 0 -1.3 -1.8 11/28/2004 18:00:00 2.2 0.2 2.6 1.5 2.2 0.2 2.6 1.5 0.4 0 0.4 0.4 56 2 50 305 69 0 68 0 -1.4 0 -1.1 -1.5 11/28/2004 18:10:00 2.5 0.3 3 1.9 2.5 0.3 3 1.9 0.4 0 0.4 0.4 57 0 57 305 69 0 69 0 -1.4 0 -1.1 -1.5 11/28/2004 18:20:00 2 0.2 2.6 1.5 2 0.2 2.3 1.5 0.4 0 0.4 0.4 64 4 68 305 69 0 69 0 -1.5 0 -1.1 -1.8 11/28/2004 18:30:00 1.4 0.4 2.3 0.7 1.4 0.4 2.3 0.7 0.4 0 0.4 0.4 64 0 64 305 69 0 69 0 -1.6 0 -1.1 -1.8 11/28/2004 18:40:00 1.3 0.4 1.9 0.4 1.4 0.3 1.9 0.7 0.4 0 0.4 0.4 58 6 56 305 69 0 69 0 -1.6 0.1 -1.1 -1.8 11/28/2004 18:50:00 1.7 0.2 2.3 1.1 1.8 0.2 2.3 1.5 0.4 0 0.4 0.4 44 3 46 305 69 0 69 0 -1.5 0 -1.1 -1.8 11/28/2004 19:00:00 1.9 0.2 2.3 1.5 2 0.2 2.3 1.5 0.4 0 0.4 0.4 48 2 46 305 69 0 67 0 -1.5 0 -1.1 -1.8 11/28/2004 19:10:00 1.7 0.2 2.3 1.1 1.8 0.2 2.3 1.5 0.4 0 0.4 0.4 56 5 57 305 69 0 69 0 -1.5 0.1 -1.1 -1.8 11/28/2004 19:20:00 2.4 0.3 3 1.9 2.5 0.2 3 1.9 0.4 0 0.4 0.4 43 3 43 305 69 0 69 0 -1.5 0 -1.1 -1.8 11/28/2004 19:30:00 3 0.2 3.4 2.6 3.1 0.2 3.4 2.6 0.4 0 0.4 0.4 34 2 36 305 69 0 69 0 -1.4 0 -0.8 -1.5 11/28/2004 19:40:00 3.2 0.2 3.4 2.6 3.2 0.2 3.8 2.6 0.4 0 0.4 0.4 27 2 30 305 70 0 69 0 -1.3 0 -0.8 -1.5 11/28/2004 19:50:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 0.4 0 0.4 0.4 27 2 27 305 70 0 70 0 -1.4 0 -1.1 -1.5 11/28/2004 20:00:00 2.4 0.2 3 1.5 2.5 0.2 3 1.9 0.4 0 0.4 0.4 29 2 27 305 70 0 70 0 -1.3 0 -1.1 -1.3 11/28/2004 20:10:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 0.4 0 0.4 0.4 30 3 29 305 69 0 69 0 -1.2 0 -1.1 -1.3 11/28/2004 20:20:00 3.2 0.3 3.8 2.6 3.1 0.3 3.8 2.6 0.4 0 0.4 0.4 30 2 27 305 69 0 69 0 -1.1 0 -1.1 -1.1 11/28/2004 20:30:00 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 0.4 0 0.4 0.4 33 2 33 305 69 0 69 0 -1 0 -0.8 -1.1 11/28/2004 20:40:00 3.8 0.8 5.7 2.6 3.7 0.7 5.3 2.6 0.4 0 0.4 0.4 44 10 48 305 69 0 69 0 -0.8 0 -0.6 -1.1 11/28/2004 20:50:00 6 0.8 8 3.8 5.6 0.8 8 3.4 0.4 0 0.4 0.4 65 5 66 305 69 0 69 0 -0.7 0 -0.6 -0.8 11/28/2004 21:00:00 7.1 0.5 8.4 6.1 6.7 0.5 8 4.9 0.4 0 0.4 0.4 67 4 70 305 69 0 69 0 -0.7 0 -0.4 -0.8 11/28/2004 21:10:00 7.6 0.5 8.4 6.1 7.4 0.6 8.4 5.7 0.4 0 0.4 0.4 62 3 59 305 70 0 70 0 -0.6 0 -0.1 -0.8 11/28/2004 21:20:00 7.5 0.5 8.8 6.1 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 65 5 68 305 70 0 70 0 -0.7 0 -0.4 -0.8 11/28/2004 21:30:00 7.3 0.5 8.4 6.1 7.2 0.6 8.4 5.7 0.4 0 0.4 0.4 64 4 64 305 70 0 70 0 -0.8 0 -0.4 -1.1 11/28/2004 21:40:00 7.7 0.4 8.8 6.5 7.4 0.5 8.8 6.1 0.4 0 0.4 0.4 66 3 68 305 70 0 70 0 -0.8 0 -0.4 -1.1 11/28/2004 21:50:00 7.7 0.5 9.1 6.5 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 70 4 69 305 71 0 71 0 -0.9 0 -0.6 -1.1 11/28/2004 22:00:00 7.9 0.5 8.8 6.5 7.6 0.5 8.4 6.5 0.4 0 0.4 0.4 72 4 73 305 70 0 71 0 -1.1 0 -0.6 -1.3 11/28/2004 22:10:00 7.7 0.7 9.1 5.7 7.2 0.9 8.8 4.9 0.4 0 0.4 0.4 75 8 69 305 70 0 70 0 -1.2 0 -0.8 -1.3 11/28/2004 22:20:00 6.8 0.8 8.4 4.6 6.3 0.8 7.6 3.8 0.4 0 0.4 0.4 89 7 88 305 70 0 70 0 -1.4 0.1 -1.1 -1.8 11/28/2004 22:30:00 6.9 0.6 8.4 4.9 6.3 0.7 7.6 4.2 0.4 0 0.4 0.4 89 7 85 305 70 0 70 0 -1.6 0 -1.1 -1.8 11/28/2004 22:40:00 7.1 0.6 8.8 5.3 6.6 0.7 8.4 4.9 0.4 0 0.4 0.4 88 8 81 305 70 0 70 0 -1.7 0 -1.3 -1.8 11/28/2004 22:50:00 6.6 0.8 8.8 3.8 6.1 0.8 8.8 3.8 0.4 0 0.4 0.4 87 9 73 305 70 0 70 0 -1.7 0 -1.3 -1.8 11/28/2004 23:00:00 6.6 0.9 8.8 4.6 6 0.9 8.4 3.8 0.4 0 0.4 0.4 87 8 78 305 70 0 70 0 -1.6 0 -1.3 -1.8 11/28/2004 23:10:00 7 0.6 8.4 5.3 6.5 0.6 7.6 4.6 0.4 0 0.4 0.4 85 7 85 305 70 0 70 0 -1.6 0 -1.1 -1.8 11/28/2004 23:20:00 7.7 0.8 9.9 5.7 7.2 0.8 9.1 4.9 0.4 0 0.4 0.4 77 6 70 305 69 0 69 0 -1.6 0.1 -1.1 -1.8 11/28/2004 23:30:00 7.2 0.7 9.1 5.3 6.9 0.8 8.8 4.9 0.4 0 0.4 0.4 73 8 72 305 70 0 70 0 -1.7 0 -1.3 -1.8 11/28/2004 23:40:00 7.3 0.6 8.8 5.7 7 0.6 8.8 5.3 0.4 0 0.4 0.4 76 6 79 305 70 0 69 0 -1.6 0 -1.1 -1.8 11/28/2004 23:50:00 7.5 0.5 8.8 6.1 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 76 6 72 305 69 0 69 0 -1.7 0 -1.3 -2 11/29/2004 00:00:00 7.6 0.6 9.1 5.7 7.2 0.7 8.8 4.9 0.4 0 0.4 0.4 76 5 73 305 69 0 69 0 -1.8 0 -1.3 -2 11/29/2004 00:10:00 7.6 0.4 8.4 5.7 7.4 0.5 8.4 5.7 0.4 0 0.4 0.4 68 3 74 305 69 0 68 0 -1.8 0 -1.8 -2 11/29/2004 00:20:00 7.3 0.6 9.1 5.3 7 0.6 9.1 4.9 0.4 0 0.4 0.4 73 5 70 305 69 0 69 0 -1.7 0 -1.8 -1.8 11/29/2004 00:30:00 7.8 0.4 9.1 6.5 7.4 0.5 8.4 6.1 0.4 0 0.4 0.4 71 5 67 305 69 0 69 0 -1.8 0 -1.8 -2 11/29/2004 00:40:00 7.8 0.6 9.1 6.1 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 72 5 75 305 69 0 69 0 -1.8 0 -1.8 -2 11/29/2004 00:50:00 7.5 0.5 8.8 5.7 7.3 0.7 8.8 5.3 0.4 0 0.4 0.4 70 4 77 305 70 0 69 0 -1.7 0 -1.5 -1.8 11/29/2004 01:00:00 7.2 0.5 9.1 6.1 6.9 0.5 8.8 4.9 0.4 0 0.4 0.4 71 5 78 305 70 0 69 0 -1.7 0 -1.5 -2 11/29/2004 01:10:00 7.2 0.5 8.8 6.1 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 71 4 70 305 70 0 70 0 -1.8 0 -1.8 -2 11/29/2004 01:20:00 7 0.7 8.8 4.9 6.6 0.7 8.4 4.9 0.4 0 0.4 0.4 76 6 73 305 70 0 70 0 -1.8 0 -1.8 -2 11/29/2004 01:30:00 6.6 0.6 8.4 4.9 6.3 0.7 8.4 4.6 0.4 0 0.4 0.4 75 6 69 305 70 0 70 0 -1.8 0 -1.8 -2 11/29/2004 01:40:00 6.9 0.6 9.1 5.3 6.5 0.6 8.4 4.9 0.4 0 0.4 0.4 73 6 67 305 70 0 69 0 -1.7 0 -1.8 -2 11/29/2004 01:50:00 6.6 0.7 8.4 4.9 6.2 0.7 8 4.6 0.4 0 0.4 0.4 77 6 76 305 70 0 70 0 -1.7 0 -1.5 -1.8 11/29/2004 02:00:00 6.7 0.6 8.4 4.2 6.2 0.6 8 4.6 0.4 0 0.4 0.4 77 8 67 305 70 0 70 0 -1.7 0 -1.5 -1.8 11/29/2004 02:10:00 6.7 0.6 8.4 4.9 6.3 0.7 8.4 4.6 0.4 0 0.4 0.4 76 7 75 305 70 0 70 0 -1.7 0 -1.5 -1.8 11/29/2004 02:20:00 6.8 0.7 8.4 4.9 6.4 0.7 8.4 4.9 0.4 0 0.4 0.4 79 7 77 305 70 0 70 0 -1.8 0 -1.8 -2 11/29/2004 02:30:00 6.9 0.6 8.4 5.7 6.6 0.6 8.4 4.9 0.4 0 0.4 0.4 72 6 75 305 70 0 70 0 -1.7 0 -1.8 -1.8 11/29/2004 02:40:00 6.8 0.6 8.4 5.3 6.5 0.7 8 4.9 0.4 0 0.4 0.4 73 6 68 305 70 0 70 0 -1.7 0 -1.8 -1.8 11/29/2004 02:50:00 7.1 0.5 8.8 5.7 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 71 5 82 305 70 0 70 0 -1.7 0 -1.8 -1.8 11/29/2004 03:00:00 6.8 0.5 8 5.7 6.6 0.5 8 5.3 0.4 0 0.4 0.4 69 5 70 305 70 0 70 0 -1.6 0 -1.3 -1.8 11/29/2004 03:10:00 7.6 0.4 8.4 6.5 7.6 0.4 8.4 6.5 0.4 0 0.4 0.4 62 3 60 305 70 0 70 0 -1.6 0 -1.1 -1.8 11/29/2004 03:20:00 7.4 0.2 8 6.5 7.4 0.3 8 6.5 0.4 0 0.4 0.4 60 3 61 305 70 0 70 0 -1.5 0.1 -1.1 -1.8 11/29/2004 03:30:00 7 0.3 8 6.5 7 0.4 8 6.1 0.4 0 0.4 0.4 59 2 58 305 70 0 70 0 -1.4 0 -1.1 -1.5 11/29/2004 03:40:00 7.1 0.3 8 6.1 7.1 0.4 8 6.1 0.4 0 0.4 0.4 52 3 48 305 70 0 70 0 -1.2 0 -0.8 -1.3 11/29/2004 03:50:00 7.1 0.4 8 5.7 7.1 0.5 8 5.3 0.4 0 0.4 0.4 55 3 52 305 70 0 70 0 -1.2 0 -0.8 -1.3 11/29/2004 04:00:00 6.6 0.4 7.6 5.7 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 56 4 48 305 70 0 70 0 -1.1 0 -1.1 -1.3 11/29/2004 04:10:00 6.3 0.5 7.6 5.3 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 56 3 60 305 70 0 70 0 -1 0 -0.8 -1.1 11/29/2004 04:20:00 6.2 0.5 7.2 4.9 6 0.6 7.2 4.6 0.4 0 0.4 0.4 57 4 51 305 71 0 71 0 -0.8 0 -0.6 -1.1 11/29/2004 04:30:00 6.9 0.4 7.6 5.3 6.7 0.5 7.6 5.3 0.4 0 0.4 0.4 55 3 61 305 71 0 71 0 -0.8 0 -0.6 -0.8 11/29/2004 04:40:00 7 0.5 8 5.7 6.8 0.5 8 5.3 0.4 0 0.4 0.4 53 3 57 305 71 0 71 0 -0.7 0 -0.6 -0.8 11/29/2004 04:50:00 7.5 0.4 8.8 6.5 7.3 0.4 8.8 6.5 0.4 0 0.4 0.4 54 3 57 305 71 0 71 0 -0.6 0 -0.4 -0.6 11/29/2004 05:00:00 7.6 0.6 8.8 6.5 7.4 0.6 8.8 6.1 0.4 0 0.4 0.4 56 3 53 305 71 0 71 0 -0.5 0 -0.1 -0.6 11/29/2004 05:10:00 7.4 0.5 8.8 6.1 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 59 4 61 305 71 0 71 0 -0.6 0 -0.1 -0.6 11/29/2004 05:20:00 7.6 0.5 8.8 6.5 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 63 3 65 305 71 0 71 0 -0.6 0 -0.1 -0.6 11/29/2004 05:30:00 7.9 0.5 9.1 6.1 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 68 4 67 305 72 1 71 0 -0.6 0 -0.4 -0.6 11/29/2004 05:40:00 7.4 0.6 9.1 6.1 6.9 0.7 8.8 5.3 0.4 0 0.4 0.4 71 5 69 305 73 0 73 0 -0.6 0 -0.1 -0.8 11/29/2004 05:50:00 8.3 0.6 9.5 6.8 7.7 0.6 9.5 6.1 0.4 0 0.4 0.4 71 4 81 305 73 0 73 0 -0.7 0 -0.4 -0.8 11/29/2004 06:00:00 7.8 0.6 9.1 6.1 7.3 0.7 8.8 5.3 0.4 0 0.4 0.4 70 4 66 305 72 0 72 0 -0.6 0 -0.4 -0.6 11/29/2004 06:10:00 7.8 0.5 8.8 6.1 7.4 0.6 8.8 6.1 0.4 0 0.4 0.4 66 4 63 305 72 0 72 0 -0.5 0.1 0.1 -0.6 11/29/2004 06:20:00 7.1 0.7 8.4 5.3 6.8 0.7 8.4 4.9 0.4 0 0.4 0.4 62 4 63 305 72 0 72 0 -0.5 0 0.1 -0.6 11/29/2004 06:30:00 7.5 0.5 8.8 4.9 7.3 0.6 8.8 4.6 0.4 0 0.4 0.4 64 4 62 305 72 0 72 0 -0.5 0 -0.1 -0.6 11/29/2004 06:40:00 7.7 0.6 9.1 6.1 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 58 3 57 305 72 0 72 0 -0.4 0 0.1 -0.6 11/29/2004 06:50:00 7.9 0.6 9.1 6.5 7.6 0.6 9.1 5.7 0.4 0 0.4 0.4 62 4 62 305 71 0 71 0 -0.5 0 0.1 -0.6 11/29/2004 07:00:00 7.9 0.5 9.1 6.5 7.6 0.6 8.8 6.1 0.4 0 0.4 0.4 63 3 69 305 71 0 71 0 -0.5 0 0.1 -0.6 11/29/2004 07:10:00 7.9 0.6 9.5 6.5 7.6 0.7 9.5 6.1 0.4 0 0.4 0.4 61 3 57 305 71 0 71 0 -0.4 0.1 0.1 -0.6 11/29/2004 07:20:00 8.6 0.6 9.9 7.2 8.3 0.6 9.9 6.5 0.4 0 0.4 0.4 56 3 55 305 70 0 70 0 -0.4 0.1 0.1 -0.6 11/29/2004 07:30:00 9.1 0.5 10.3 7.2 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 54 3 55 305 70 0 70 0 -0.5 0 0.1 -0.6 11/29/2004 07:40:00 8.6 0.5 9.9 7.2 8.4 0.5 9.9 7.2 0.4 0 0.4 0.4 55 2 54 305 70 0 69 0 -0.5 0.1 0.1 -0.6 11/29/2004 07:50:00 8.2 0.5 9.9 6.8 7.9 0.5 9.5 6.1 0.4 0 0.4 0.4 54 4 53 305 70 0 70 0 -0.5 0.1 0.1 -0.6 11/29/2004 08:00:00 7.9 0.5 9.1 6.8 7.6 0.5 8.8 6.1 0.4 0 0.4 0.4 51 3 52 305 69 0 68 0 -0.5 0 0.1 -0.6 11/29/2004 08:10:00 7.9 0.4 8.8 6.5 7.7 0.5 8.8 6.5 0.4 0 0.4 0.4 53 3 56 305 69 0 69 0 -0.5 0 -0.4 -0.6 11/29/2004 08:20:00 7.8 0.4 8.8 6.8 7.6 0.4 8.4 6.5 0.4 0 0.4 0.4 52 3 55 305 69 0 69 0 -0.4 0 -0.4 -0.6 11/29/2004 08:30:00 7.8 0.5 8.8 6.5 7.5 0.6 8.8 6.5 0.4 0 0.4 0.4 51 4 48 305 69 0 69 0 -0.4 0 -0.4 -0.6 11/29/2004 08:40:00 7.5 0.6 9.1 6.5 7.3 0.6 8.8 6.1 0.4 0 0.4 0.4 51 3 50 305 68 0 68 0 -0.4 0 -0.4 -0.6 11/29/2004 08:50:00 7.5 0.5 8.4 6.1 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 52 4 53 305 68 0 68 0 -0.4 0 0.3 -0.4 11/29/2004 09:00:00 7.7 0.5 8.8 6.1 7.4 0.5 8.4 6.1 0.4 0 0.4 0.4 50 3 53 305 68 0 68 0 -0.4 0.1 0.1 -0.6 11/29/2004 09:10:00 7.6 0.4 8.8 6.5 7.3 0.4 8.4 5.7 0.4 0 0.4 0.4 44 3 42 305 68 0 68 0 -0.3 0 0.3 -0.4 11/29/2004 09:20:00 7.5 0.5 8.8 6.5 7.2 0.5 8.4 6.1 0.4 0 0.4 0.4 45 3 50 305 68 0 68 0 -0.4 0 0.3 -0.4 11/29/2004 09:30:00 7.5 0.4 8.4 6.5 7.2 0.4 8.4 6.1 0.4 0 0.4 0.4 51 3 48 305 68 0 68 0 -0.3 0 0.1 -0.4 11/29/2004 09:40:00 7.4 0.5 9.1 6.1 7.1 0.6 9.1 5.3 0.4 0 0.4 0.4 53 3 51 305 68 0 68 0 -0.3 0 0.3 -0.4 11/29/2004 09:50:00 8.4 0.4 9.1 7.6 8.1 0.4 9.1 6.5 0.4 0 0.4 0.4 51 3 47 305 68 0 68 0 -0.3 0 0.3 -0.4 11/29/2004 10:00:00 8.2 0.4 9.5 7.2 7.9 0.4 9.1 6.8 0.4 0 0.4 0.4 56 3 52 305 68 0 68 0 -0.3 0 -0.1 -0.4 11/29/2004 10:10:00 7.8 0.4 8.8 6.5 7.5 0.4 8.4 6.1 0.4 0 0.4 0.4 59 3 65 305 68 0 68 0 -0.3 0 0.1 -0.4 11/29/2004 10:20:00 7.7 0.4 8.8 6.5 7.3 0.4 8.4 6.1 0.4 0 0.4 0.4 62 3 59 305 69 0 69 0 -0.3 0 -0.1 -0.4 11/29/2004 10:30:00 7.6 0.4 8.8 6.8 7.3 0.4 8 6.1 0.4 0 0.4 0.4 61 3 61 305 70 0 70 0 -0.3 0 0.1 -0.4 11/29/2004 10:40:00 7.6 0.4 8.4 6.8 7.3 0.4 8.4 6.1 0.4 0 0.4 0.4 57 3 60 305 70 0 70 0 -0.2 0 0.1 -0.4 11/29/2004 10:50:00 7.7 0.3 8.4 6.8 7.4 0.4 8.4 6.1 0.4 0 0.4 0.4 53 2 52 305 70 0 70 0 -0.2 0 0.1 -0.4 11/29/2004 11:00:00 7.4 0.3 8 6.8 7.1 0.3 8 6.5 0.4 0 0.4 0.4 51 2 53 305 70 0 70 0 -0.1 0 0.3 -0.4 11/29/2004 11:10:00 7.3 0.3 8 6.5 7 0.4 8 6.1 0.4 0 0.4 0.4 56 3 54 305 70 0 70 0 -0.2 0 0.3 -0.4 11/29/2004 11:20:00 7.7 0.8 10.7 6.1 7.3 0.8 10.3 5.7 0.4 0 0.4 0.4 61 5 76 305 70 0 71 0 -0.3 0 0.3 -0.4 11/29/2004 11:30:00 8.7 0.7 10.3 6.5 8.2 0.8 9.9 6.1 0.4 0 0.4 0.4 78 5 77 305 70 0 70 0 -0.5 0.1 0.1 -0.6 11/29/2004 11:40:00 8.8 0.6 9.9 6.8 8.4 0.6 9.5 6.5 0.4 0 0.4 0.4 76 5 73 305 70 0 70 0 -0.5 0.1 0.1 -0.6 11/29/2004 11:50:00 8.8 0.6 10.7 7.2 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 76 5 73 305 71 0 70 0 -0.5 0 0.1 -0.6 11/29/2004 12:00:00 8.8 0.6 10.3 7.2 8.4 0.7 10.3 6.5 0.4 0 0.4 0.4 77 5 75 305 71 0 71 0 -0.5 0 0.1 -0.6 11/29/2004 12:10:00 8.8 0.6 9.9 6.8 8.3 0.6 9.9 6.5 0.4 0 0.4 0.4 75 5 82 305 71 0 71 0 -0.6 0 -0.1 -0.6 11/29/2004 12:20:00 8.7 0.6 9.9 6.8 8.3 0.6 9.5 6.5 0.4 0 0.4 0.4 73 4 73 305 72 0 72 0 -0.6 0 -0.1 -0.6 11/29/2004 12:30:00 8.6 0.6 10.3 7.2 8.3 0.7 10.3 6.5 0.4 0 0.4 0.4 68 5 69 305 75 0 74 0 -0.6 0 -0.4 -0.8 11/29/2004 12:40:00 7.9 0.5 9.1 6.5 7.7 0.6 9.1 6.5 0.4 0 0.4 0.4 62 3 62 305 75 0 74 0 -0.6 0 0.1 -0.6 11/29/2004 12:50:00 8.1 0.9 10.3 6.5 7.9 1 10.3 6.1 0.4 0 0.4 0.4 65 3 66 305 76 0 76 0 -0.5 0 0.1 -0.6 11/29/2004 13:00:00 9.2 0.7 10.7 7.2 9 0.7 10.7 6.8 0.4 0 0.4 0.4 67 3 65 305 76 0 76 0 -0.5 0 0.1 -0.6 11/29/2004 13:10:00 9.4 0.6 10.7 7.6 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 64 4 65 305 77 0 77 0 -0.6 0 -0.4 -0.6 11/29/2004 13:20:00 8.7 0.7 10.7 6.8 8.4 0.7 10.3 6.5 0.4 0 0.4 0.4 60 3 59 305 77 0 77 0 -0.6 0 0.1 -0.6 11/29/2004 13:30:00 8.4 0.6 9.5 6.8 8 0.6 9.5 6.5 0.4 0 0.4 0.4 58 4 57 305 77 0 78 0 -0.5 0 -0.1 -0.6 11/29/2004 13:40:00 8.7 0.4 9.5 7.6 8.5 0.4 9.5 7.2 0.4 0 0.4 0.4 55 2 56 305 78 0 78 0 -0.6 0 -0.4 -0.6 11/29/2004 13:50:00 8.5 0.5 9.9 7.2 8.2 0.5 9.9 6.8 0.4 0 0.4 0.4 62 4 64 305 78 0 78 0 -0.6 0 0.1 -0.6 11/29/2004 14:00:00 8.2 0.7 9.9 6.5 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 62 5 66 305 78 0 78 0 -0.6 0 -0.4 -0.6 11/29/2004 14:10:00 8.6 0.7 10.3 6.8 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 67 4 69 305 78 0 78 0 -0.6 0 -0.1 -0.6 11/29/2004 14:20:00 9.9 0.6 11.5 8.4 9.6 0.6 11.1 7.6 0.4 0 0.4 0.4 63 5 67 305 78 0 78 0 -0.7 0 -0.1 -0.8 11/29/2004 14:30:00 9.3 0.5 10.3 8 9 0.5 10.3 7.6 0.4 0 0.4 0.4 53 4 57 305 78 0 78 0 -0.8 0 -0.4 -1.1 11/29/2004 14:40:00 8.9 0.7 10.7 7.2 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 48 3 48 305 78 0 78 0 -0.8 0 -0.4 -0.8 11/29/2004 14:50:00 9 0.5 10.3 7.6 8.7 0.5 10.3 7.6 0.4 0 0.4 0.4 49 3 51 305 77 0 77 0 -0.7 0 -0.4 -0.8 11/29/2004 15:00:00 9.9 0.6 11.1 8 9.6 0.7 11.1 7.6 0.4 0 0.4 0.4 47 3 50 305 77 0 77 0 -0.6 0 -0.4 -0.6 11/29/2004 15:10:00 9.9 0.6 11.1 8.4 9.4 0.7 11.1 7.6 0.4 0 0.4 0.4 46 3 48 305 77 0 77 0 -0.6 0 0.1 -0.8 11/29/2004 15:20:00 9.9 0.6 11.5 8 9.5 0.7 11.5 8 0.4 0 0.4 0.4 43 3 45 305 77 0 77 0 -0.6 0 0.1 -0.6 11/29/2004 15:30:00 9.9 0.6 11.5 8.4 9.6 0.6 11.1 8 0.4 0 0.4 0.4 43 3 41 305 76 0 76 0 -0.5 0 0.1 -0.6 11/29/2004 15:40:00 9.9 0.6 11.5 8.4 9.6 0.6 11.1 8 0.4 0 0.4 0.4 44 3 46 305 75 0 75 0 -0.5 0 0.1 -0.6 11/29/2004 15:50:00 10.7 0.6 12.2 9.1 10.3 0.8 11.8 8.4 0.4 0 0.4 0.4 43 3 43 305 74 0 74 0 -0.5 0 0.1 -0.6 11/29/2004 16:00:00 11.3 0.5 12.6 9.9 10.9 0.6 12.2 9.1 0.4 0 0.4 0.4 45 3 45 305 73 0 73 0 -0.5 0 0.1 -0.6 11/29/2004 16:10:00 11.1 0.7 13 9.1 10.7 0.8 12.6 8.4 0.4 0 0.4 0.4 43 3 43 305 73 0 73 0 -0.7 0 0.1 -0.8 11/29/2004 16:20:00 10.8 0.7 12.2 8.8 10.5 0.8 11.8 8 0.4 0 0.4 0.4 41 3 43 305 72 0 72 0 -0.7 0 -0.1 -0.8 11/29/2004 16:30:00 11 0.6 12.2 9.1 10.7 0.7 12.2 8.8 0.4 0 0.4 0.4 39 3 42 305 72 0 72 0 -0.7 0 -0.1 -0.8 11/29/2004 16:40:00 11 0.6 12.2 9.1 10.8 0.7 12.2 8.4 0.4 0 0.4 0.4 38 2 38 305 72 0 72 0 -0.8 0 -0.1 -0.8 11/29/2004 16:50:00 10.4 0.6 11.8 8.4 10.1 0.7 11.8 7.6 0.4 0 0.4 0.4 39 3 42 305 72 0 72 0 -0.7 0 -0.1 -0.8 11/29/2004 17:00:00 11.1 0.6 12.6 9.1 10.8 0.7 12.6 8.8 0.4 0 0.4 0.4 41 3 42 305 72 0 72 0 -0.7 0 -0.1 -0.8 11/29/2004 17:10:00 11.1 0.8 12.6 9.1 10.9 0.8 12.6 8.8 0.4 0 0.4 0.4 40 3 37 305 72 0 72 0 -0.8 0 -0.6 -1.1 11/29/2004 17:20:00 11 0.7 12.2 8.8 10.8 0.8 12.2 8.4 0.4 0 0.4 0.4 40 3 38 305 72 0 72 0 -0.7 0 -0.6 -0.8 11/29/2004 17:30:00 11.1 0.6 12.6 9.5 10.8 0.7 12.6 8.4 0.4 0 0.4 0.4 40 3 39 305 71 0 72 0 -0.7 0 -0.4 -0.8 11/29/2004 17:40:00 11.8 0.5 13 10.3 11.5 0.6 13 9.1 0.4 0 0.4 0.4 41 3 40 305 71 0 71 0 -0.8 0 -0.4 -0.8 11/29/2004 17:50:00 11.1 0.6 12.6 9.5 10.8 0.6 12.6 9.1 0.4 0 0.4 0.4 42 3 41 305 70 0 70 0 -0.7 0 -0.6 -0.8 11/29/2004 18:00:00 10.8 0.6 12.2 9.1 10.5 0.7 12.6 8 0.4 0 0.4 0.4 42 3 44 305 70 0 70 0 -0.6 0 0.1 -0.6 11/29/2004 18:10:00 10.6 0.5 12.6 9.1 10.3 0.6 11.8 8.4 0.4 0 0.4 0.4 46 3 48 305 70 0 69 0 -0.6 0 0.1 -0.6 11/29/2004 18:20:00 10.3 0.7 12.2 8.8 10 0.8 11.8 8 0.4 0 0.4 0.4 48 3 47 305 69 0 69 0 -0.5 0 0.1 -0.6 11/29/2004 18:30:00 10.4 0.8 12.6 8.4 10.1 0.9 12.2 8 0.4 0 0.4 0.4 47 4 50 305 69 1 69 0 -0.6 0 0.1 -0.6 11/29/2004 18:40:00 10.6 0.5 11.8 9.1 10.2 0.6 11.8 8.8 0.4 0 0.4 0.4 47 4 47 305 70 0 70 0 -0.6 0 0.1 -0.6 11/29/2004 18:50:00 10.9 0.8 12.6 8.4 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 45 3 48 305 70 0 70 0 -0.6 0 0.1 -0.6 11/29/2004 19:00:00 11.7 0.7 13.3 9.9 11.4 0.8 13 9.5 0.4 0 0.4 0.4 46 3 40 305 70 0 70 0 -0.6 0 0.1 -0.6 11/29/2004 19:10:00 12 0.8 14.5 9.9 11.7 0.9 14.5 9.5 0.4 0 0.4 0.4 46 3 46 305 70 0 70 0 -0.6 0 0.1 -0.8 11/29/2004 19:20:00 11.7 1 14.1 9.1 11.2 1.1 13.7 8.4 0.4 0 0.4 0.4 47 4 52 305 70 0 70 0 -0.6 0 0.1 -0.6 11/29/2004 19:30:00 11.8 0.9 13.7 9.5 11.6 1 13.3 8.8 0.4 0 0.4 0.4 44 3 40 305 70 0 70 0 -0.6 0 0.1 -0.6 11/29/2004 19:40:00 12.1 0.9 14.5 9.9 11.7 1 14.5 8.8 0.4 0 0.4 0.4 43 3 42 305 70 0 70 0 -0.6 0 -0.4 -0.6 11/29/2004 19:50:00 11.8 0.9 14.1 9.5 11.6 1 13.7 9.1 0.4 0 0.4 0.4 43 3 41 305 70 0 70 0 -0.6 0 0.1 -0.6 11/29/2004 20:00:00 11.8 0.8 13.3 9.9 11.5 0.8 13.7 9.1 0.4 0 0.4 0.4 47 3 48 305 70 0 70 0 -0.6 0 -0.4 -0.6 11/29/2004 20:10:00 11.7 0.7 13.3 9.9 11.4 0.8 13.3 9.1 0.4 0 0.4 0.4 44 4 39 305 70 0 70 0 -0.5 0 -0.4 -0.6 11/29/2004 20:20:00 11.9 0.7 13.7 9.5 11.5 0.8 13.3 9.1 0.4 0 0.4 0.4 42 3 43 305 71 0 71 0 -0.5 0 -0.4 -0.6 11/29/2004 20:30:00 12 0.8 14.1 9.9 11.6 0.8 13.3 9.5 0.4 0 0.4 0.4 43 4 38 305 71 0 71 0 -0.4 0 -0.1 -0.6 11/29/2004 20:40:00 11.3 0.8 13 9.1 10.9 0.8 13 8.8 0.4 0 0.4 0.4 45 4 52 305 71 0 71 0 -0.5 0 -0.4 -0.6 11/29/2004 20:50:00 11 0.9 13.3 8.8 10.7 1 13 8.4 0.4 0 0.4 0.4 44 4 42 305 72 0 72 0 -0.5 0 -0.4 -0.6 11/29/2004 21:00:00 11.2 0.8 13.3 9.1 10.9 0.9 13.3 8.4 0.4 0 0.4 0.4 44 3 37 305 72 0 72 0 -0.5 0 0.1 -0.6 11/29/2004 21:10:00 11.8 0.6 13.3 10.3 11.4 0.7 13.3 9.5 0.4 0 0.4 0.4 42 3 37 305 73 0 72 0 -0.6 0 0.1 -0.6 11/29/2004 21:20:00 11.5 0.7 13.3 9.5 11.3 0.8 13.3 9.1 0.4 0 0.4 0.4 39 3 39 305 73 0 73 0 -0.6 0 0.1 -0.6 11/29/2004 21:30:00 11.5 0.7 12.6 9.1 11.1 0.7 13 8.4 0.4 0 0.4 0.4 38 3 42 305 73 0 73 0 -0.5 0 0.1 -0.6 11/29/2004 21:40:00 11.2 0.7 12.6 9.5 10.8 0.8 12.6 9.1 0.4 0 0.4 0.4 38 3 38 305 73 0 73 0 -0.5 0 0.1 -0.6 11/29/2004 21:50:00 10.5 0.6 11.8 8.8 10.2 0.7 11.8 8 0.4 0 0.4 0.4 38 3 42 305 74 0 74 0 -0.5 0.1 0.1 -0.6 11/29/2004 22:00:00 10.5 0.6 12.2 8.4 10.1 0.7 11.5 8.4 0.4 0 0.4 0.4 36 3 33 305 74 0 74 0 -0.5 0.1 0.1 -0.6 11/29/2004 22:10:00 10 0.7 11.5 8 9.7 0.7 11.5 7.6 0.4 0 0.4 0.4 31 3 30 305 74 0 74 0 -0.5 0.1 0.1 -0.6 11/29/2004 22:20:00 9.9 1 12.2 7.6 9.5 1 12.2 7.6 0.4 0 0.4 0.4 32 4 32 305 73 0 73 0 -0.5 0.1 0.1 -0.6 11/29/2004 22:30:00 10 0.7 11.8 8 9.7 0.8 11.5 8 0.4 0 0.4 0.4 32 3 37 305 73 0 72 0 -0.4 0.1 0.1 -0.6 11/29/2004 22:40:00 9.7 1.2 11.8 6.1 9.4 1.2 11.8 6.1 0.4 0 0.4 0.4 30 4 31 305 73 0 73 0 -0.5 0.1 0.1 -0.6 11/29/2004 22:50:00 8.7 1.3 11.1 5.7 8.5 1.3 11.1 5.3 0.4 0 0.4 0.4 30 7 24 305 74 1 73 0 -0.4 0 0.1 -0.6 11/29/2004 23:00:00 7.6 1.4 9.9 4.9 7.4 1.4 9.9 4.9 0.4 0 0.4 0.4 27 6 23 305 75 0 75 0 -0.4 0 0.1 -0.6 11/29/2004 23:10:00 7.4 1.3 9.9 4.9 7.3 1.3 9.5 4.6 0.4 0 0.4 0.4 28 6 25 305 74 0 75 0 -0.3 0 0.3 -0.4 11/29/2004 23:20:00 7.7 0.5 9.1 6.5 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 24 4 25 305 73 1 74 0 -0.3 0 0.3 -0.4 11/29/2004 23:30:00 7 0.9 8.8 4.6 6.9 0.9 8.8 4.6 0.4 0 0.4 0.4 24 6 20 305 72 0 72 0 -0.3 0 0.3 -0.4 11/29/2004 23:40:00 5.3 1.3 7.6 3 5.2 1.3 7.6 2.6 0.4 0 0.4 0.4 31 7 20 305 73 0 73 0 -0.3 0 0.3 -0.4 11/29/2004 23:50:00 3.6 0.5 4.6 2.6 3.6 0.4 4.6 2.6 0.4 0 0.4 0.4 38 0 38 305 74 1 75 0 -0.3 0 0.3 -0.4 11/30/2004 00:00:00 4 0.2 4.6 3.8 4.1 0.2 4.6 3.8 0.4 0 0.4 0.4 38 0 38 305 75 0 75 0 -0.4 0.1 0.1 -0.6 11/30/2004 00:10:00 3.9 0.2 4.6 3.4 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 38 0 38 305 75 0 75 0 -0.5 0 0.1 -0.6 11/30/2004 00:20:00 3.3 0.3 3.8 2.6 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 38 0 38 305 75 0 75 0 -0.5 0 0.1 -0.6 11/30/2004 00:30:00 2.6 0.5 3.4 1.5 2.6 0.4 3.4 1.9 0.4 0 0.4 0.4 38 0 38 305 74 0 74 0 -0.6 0 0.1 -0.6 11/30/2004 00:40:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 0.4 0 0.4 0.4 38 0 38 305 74 0 73 0 -0.5 0 0.1 -0.6 11/30/2004 00:50:00 1.9 0.4 2.6 1.1 1.9 0.3 2.6 1.1 0.4 0 0.4 0.4 42 7 38 305 73 0 74 0 -0.7 0 0.1 -0.8 11/30/2004 01:00:00 2.6 0.6 4.2 1.1 2.6 0.5 3.8 1.5 0.4 0 0.4 0.4 57 1 57 305 79 10 74 0 -0.9 0 -0.4 -1.1 11/30/2004 01:10:00 2.4 0.4 3.4 1.1 2.4 0.4 3 1.5 0.4 0 0.4 0.4 60 0 59 305 117 1 113 0 -0.9 0 -0.4 -1.1 11/30/2004 01:20:00 3.1 0.5 4.2 1.5 3.1 0.6 4.2 1.9 0.4 0 0.4 0.4 58 1 58 305 118 0 118 0 -1 0.1 -0.6 -1.1 11/30/2004 01:30:00 4.3 0.6 6.1 3 4.3 0.6 5.7 3 0.4 0 0.4 0.4 56 0 56 305 119 1 120 0 -1 0 -0.4 -1.1 11/30/2004 01:40:00 3.1 0.5 4.6 1.9 3.3 0.5 4.2 1.9 0.4 0 0.4 0.4 55 0 55 305 125 2 123 0 -0.8 0 -0.4 -1.1 11/30/2004 01:50:00 4.4 0.5 5.3 3 4.2 0.5 4.9 3 0.4 0 0.4 0.4 53 1 53 305 136 7 133 0 -1 0.1 -0.4 -1.1 11/30/2004 02:00:00 4.1 0.8 5.3 1.9 4.1 0.7 4.9 2.6 0.4 0 0.4 0.4 52 0 53 305 126 16 140 0 -1.1 0 -0.6 -1.3 11/30/2004 02:10:00 4.5 0.3 5.3 3.8 4.5 0.4 4.9 3 0.4 0 0.4 0.4 51 0 51 305 105 1 106 0 -1.5 0.1 -1.1 -1.8 11/30/2004 02:20:00 3.4 0.6 4.9 1.9 3.3 0.7 4.9 1.9 0.4 0 0.4 0.4 50 0 51 305 104 0 102 0 -1.6 0.1 -1.1 -1.8 11/30/2004 02:30:00 2.5 0.7 3.8 0.4 2.4 0.8 3.8 0.4 0.4 0 0.4 0.4 51 0 51 305 105 1 104 0 -1.6 0.1 -1.1 -1.8 11/30/2004 02:40:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 49 1 50 305 106 0 106 0 -1.8 0 -1.3 -2 11/30/2004 02:50:00 2.2 1.6 4.9 0.4 1.9 1.4 4.6 0.4 0.4 0 0.4 0.4 50 0 51 305 108 1 109 0 -1.6 0 -1.3 -1.8 11/30/2004 03:00:00 3 0.7 4.9 1.9 2.8 0.6 5.3 1.9 0.4 0 0.4 0.4 54 1 54 305 111 1 112 0 -1.1 0 -1.1 -1.3 11/30/2004 03:10:00 5.4 0.4 6.5 4.2 4.9 0.4 6.1 3.8 0.4 0 0.4 0.4 54 0 54 305 114 1 116 0 -1 0 -0.4 -1.1 11/30/2004 03:20:00 5.2 0.3 6.1 4.6 4.8 0.3 5.3 3.8 0.4 0 0.4 0.4 54 0 54 305 118 1 117 0 -0.9 0 -0.6 -1.1 11/30/2004 03:30:00 5 0.3 5.7 4.2 4.5 0.3 5.3 3.8 0.4 0 0.4 0.4 53 1 54 305 121 0 120 0 -1 0 -0.8 -1.1 11/30/2004 03:40:00 5.1 0.4 6.1 3.8 4.7 0.4 5.7 3.8 0.4 0 0.4 0.4 52 0 52 305 122 1 121 0 -0.9 0 -0.4 -1.1 11/30/2004 03:50:00 4.7 0.4 5.3 3.8 4.5 0.4 5.3 3.8 0.4 0 0.4 0.4 53 1 52 305 124 1 122 0 -0.7 0 -0.6 -0.8 11/30/2004 04:00:00 4.8 0.4 5.7 3.8 4.6 0.4 6.1 3.4 0.4 0 0.4 0.4 53 0 53 305 128 1 128 0 -0.8 0 -0.4 -1.1 11/30/2004 04:10:00 3.9 0.4 5.3 3 3.7 0.4 4.9 2.6 0.4 0 0.4 0.4 53 0 53 305 129 0 128 0 -0.8 0 -0.4 -0.8 11/30/2004 04:20:00 4.7 0.3 5.3 4.2 4.4 0.3 5.3 3.8 0.4 0 0.4 0.4 55 1 54 305 129 0 129 0 -0.8 0 -0.4 -1.1 11/30/2004 04:30:00 5.6 0.6 6.8 4.2 5.2 0.7 6.5 3.8 0.4 0 0.4 0.4 57 0 57 305 130 0 130 0 -0.7 0 -0.4 -0.8 11/30/2004 04:40:00 7.2 0.4 8.4 6.1 6.8 0.4 7.6 5.7 0.4 0 0.4 0.4 59 1 61 305 129 1 130 0 -0.5 0 0.1 -0.6 11/30/2004 04:50:00 7.7 0.4 8.8 6.5 7.3 0.4 8.4 6.5 0.4 0 0.4 0.4 62 3 64 305 125 1 125 0 -0.3 0 0.1 -0.4 11/30/2004 05:00:00 8.3 0.4 9.1 6.8 7.9 0.4 8.8 6.8 0.4 0 0.4 0.4 68 2 70 305 123 0 122 0 -0.1 0 0.3 -0.4 11/30/2004 05:10:00 8.3 0.3 9.1 7.6 7.9 0.3 8.8 7.2 0.4 0 0.4 0.4 73 1 72 305 119 1 121 0 -0.1 0 0.1 -0.1 11/30/2004 05:20:00 8.2 0.3 8.8 7.2 7.8 0.3 8.8 6.8 0.4 0 0.4 0.4 76 0 75 305 114 2 117 0 0 0 0.1 -0.1 11/30/2004 05:30:00 8.1 0.4 8.8 7.2 7.8 0.4 8.8 6.5 0.4 0 0.4 0.4 78 1 77 305 109 0 109 0 0 0 0.1 -0.1 11/30/2004 05:40:00 8.4 0.3 9.1 7.6 8 0.4 8.8 6.8 0.4 0 0.4 0.4 77 0 78 305 108 1 108 0 0 0 0.1 0.1 11/30/2004 05:50:00 8.4 0.4 9.1 7.2 8.1 0.4 9.1 7.2 0.4 0 0.4 0.4 72 2 76 305 106 1 107 0 0 0 0.1 -0.1 11/30/2004 06:00:00 8.2 0.4 9.5 6.8 7.9 0.4 9.1 6.8 0.4 0 0.4 0.4 67 1 70 305 104 0 105 0 0 0 0.6 -0.1 11/30/2004 06:10:00 8.1 0.3 8.8 7.2 7.7 0.4 8.8 6.8 0.4 0 0.4 0.4 64 1 65 305 105 1 105 0 -0.1 0 0.1 -0.1 11/30/2004 06:20:00 8 0.3 8.8 7.2 7.7 0.4 8.8 6.8 0.4 0 0.4 0.4 61 1 62 305 107 0 106 0 -0.1 0 0.1 -0.1 11/30/2004 06:30:00 8 0.4 8.8 6.8 7.7 0.4 8.8 6.8 0.4 0 0.4 0.4 59 0 60 305 106 1 107 0 -0.1 0 0.1 -0.1 11/30/2004 06:40:00 8.1 0.3 8.8 7.2 7.8 0.4 8.8 6.8 0.4 0 0.4 0.4 57 0 58 305 105 0 105 0 -0.1 0 0.1 -0.1 11/30/2004 06:50:00 8 0.3 8.8 6.8 7.8 0.3 8.8 6.8 0.4 0 0.4 0.4 56 0 57 305 105 0 104 0 -0.1 0 0.1 -0.1 11/30/2004 07:00:00 8 0.3 8.8 6.8 7.7 0.4 8.8 6.5 0.4 0 0.4 0.4 56 0 56 305 103 2 105 0 -0.1 0 0.1 -0.1 11/30/2004 07:10:00 8 0.4 8.8 6.8 7.7 0.4 9.1 6.5 0.4 0 0.4 0.4 55 0 56 305 105 0 107 0 -0.1 0 0.6 -0.1 11/30/2004 07:20:00 8.2 0.4 9.1 6.8 7.9 0.4 9.1 6.5 0.4 0 0.4 0.4 54 0 54 305 108 2 108 0 -0.1 0 0.6 -0.1 11/30/2004 07:30:00 8.3 0.4 9.5 7.6 8 0.4 9.1 6.8 0.4 0 0.4 0.4 54 0 54 305 111 1 111 0 -0.1 0 0.1 -0.1 11/30/2004 07:40:00 8.6 0.5 9.5 7.2 8.4 0.5 9.5 6.8 0.4 0 0.4 0.4 55 0 55 305 111 1 112 0 -0.1 0 0.3 -0.1 11/30/2004 07:50:00 8.6 0.5 9.9 7.2 8.4 0.5 9.5 6.8 0.4 0 0.4 0.4 54 0 54 305 111 0 111 0 -0.1 0 0.1 -0.1 11/30/2004 08:00:00 8.8 0.4 9.9 7.6 8.5 0.4 9.5 7.2 0.4 0 0.4 0.4 54 0 54 305 110 0 110 0 -0.1 0 0.6 -0.1 11/30/2004 08:10:00 8.7 0.4 9.9 7.6 8.5 0.5 9.9 7.2 0.4 0 0.4 0.4 54 0 54 305 109 0 109 0 -0.1 0 0.3 -0.1 11/30/2004 08:20:00 8.7 0.5 9.9 7.2 8.4 0.5 9.5 6.8 0.4 0 0.4 0.4 54 0 54 305 109 0 109 0 0 0 0.6 -0.1 11/30/2004 08:30:00 8.9 0.4 9.9 7.6 8.7 0.5 10.3 7.2 0.4 0 0.4 0.4 54 0 53 305 108 0 107 0 -0.1 0 0.3 -0.1 11/30/2004 08:40:00 9.2 0.5 10.3 7.2 9.1 0.5 10.3 7.6 0.4 0 0.4 0.4 54 0 54 305 106 0 107 0 0 0 0.6 -0.1 11/30/2004 08:50:00 9.3 0.5 10.3 7.6 9.1 0.5 10.3 7.6 0.4 0 0.4 0.4 53 0 53 305 106 0 105 0 -0.1 0 0.6 -0.1 11/30/2004 09:00:00 9.1 0.5 10.3 7.6 8.8 0.5 9.9 7.6 0.4 0 0.4 0.4 52 0 53 305 106 0 105 0 -0.1 0 0.3 -0.1 11/30/2004 09:10:00 9.5 0.6 10.7 8 9.4 0.6 10.7 8 0.4 0 0.4 0.4 52 0 52 305 105 0 105 0 0 0 0.6 -0.1 11/30/2004 09:20:00 9.5 0.5 10.7 8 9.2 0.5 10.7 8 0.4 0 0.4 0.4 51 0 51 305 106 1 105 0 0 0 0.6 -0.1 11/30/2004 09:30:00 9.3 0.5 11.1 8 9.1 0.5 10.7 7.6 0.4 0 0.4 0.4 50 0 50 305 107 1 107 0 0 0 0.1 -0.1 11/30/2004 09:40:00 9.6 0.6 11.1 8 9.5 0.6 11.1 7.6 0.4 0 0.4 0.4 49 0 50 305 107 0 107 0 0 0 0.1 -0.1 11/30/2004 09:50:00 9.6 0.5 11.1 8.4 9.4 0.5 10.7 8.4 0.4 0 0.4 0.4 49 0 49 305 107 0 107 0 0 0 0.1 0.1 11/30/2004 10:00:00 9.6 0.6 11.1 8.4 9.4 0.6 11.1 8 0.4 0 0.4 0.4 48 0 48 305 107 0 107 0 0 0 0.6 0.1 11/30/2004 10:10:00 9.7 0.6 11.5 8 9.7 0.6 11.5 8 0.4 0 0.4 0.4 49 0 48 305 108 0 108 0 0 0.1 0.6 0.1 11/30/2004 10:20:00 10.1 0.6 11.8 8.4 9.9 0.7 11.8 8.4 0.4 0 0.4 0.4 49 0 48 305 108 1 108 0 0 0 0.6 0.1 11/30/2004 10:30:00 9.9 0.6 11.5 8 9.8 0.7 11.5 8.4 0.4 0 0.4 0.4 49 0 49 305 108 1 108 0 0 0 0.6 0.1 11/30/2004 10:40:00 9.6 0.6 11.1 8 9.5 0.6 11.1 8 0.4 0 0.4 0.4 49 0 49 305 107 0 107 0 0 0 0.6 -0.1 11/30/2004 10:50:00 9.8 0.6 11.1 8.4 9.8 0.6 11.1 7.6 0.4 0 0.4 0.4 50 0 49 305 108 0 108 0 0 0 0.3 -0.1 11/30/2004 11:00:00 9.5 0.6 11.1 7.6 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 50 0 50 305 107 0 107 0 -0.1 0 0.3 -0.1 11/30/2004 11:10:00 9.3 0.6 10.7 8 9.3 0.6 11.1 7.6 0.4 0 0.4 0.4 51 0 51 305 107 0 107 0 -0.1 0 0.3 -0.1 11/30/2004 11:20:00 9.6 0.6 11.1 8 9.4 0.6 11.1 7.6 0.4 0 0.4 0.4 51 0 51 305 108 0 108 0 -0.1 0 0.3 -0.4 11/30/2004 11:30:00 10.1 0.9 12.6 8 10 1 13 8.4 0.4 0 0.4 0.4 52 0 52 305 108 0 109 0 -0.2 0 0.3 -0.4 11/30/2004 11:40:00 10.3 0.7 11.8 8 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 52 0 52 305 109 0 109 0 -0.3 0 0.3 -0.4 11/30/2004 11:50:00 9.6 0.8 11.8 7.6 9.6 0.8 11.5 7.2 0.4 0 0.4 0.4 52 0 52 305 109 1 109 0 -0.3 0 -0.1 -0.4 11/30/2004 12:00:00 10 0.8 12.2 8.4 9.9 0.9 12.2 8 0.4 0 0.4 0.4 52 0 52 305 104 2 104 0 -0.3 0 0.3 -0.4 11/30/2004 12:10:00 10.1 0.7 11.8 8 10 0.8 11.8 8.4 0.4 0 0.4 0.4 53 0 52 305 101 1 102 0 -0.3 0 0.1 -0.4 11/30/2004 12:20:00 10 0.8 12.2 8 10 0.8 12.2 7.2 0.4 0 0.4 0.4 53 0 53 305 99 0 99 0 -0.4 0 -0.1 -0.4 11/30/2004 12:30:00 10.2 0.8 11.8 8 10.2 0.8 12.2 8 0.4 0 0.4 0.4 52 0 53 305 94 2 91 0 -0.5 0 -0.4 -0.6 11/30/2004 12:40:00 9.9 1 12.6 8 9.8 0.9 11.8 7.6 0.4 0 0.4 0.4 51 1 51 305 88 1 88 0 -0.6 0 -0.4 -0.6 11/30/2004 12:50:00 10 1 12.2 8 9.9 0.9 12.2 8 0.4 0 0.4 0.4 59 1 59 305 87 0 88 0 -0.7 0 -0.6 -0.8 11/30/2004 13:00:00 10.5 0.7 12.2 8.8 10.5 0.8 12.6 8.4 0.4 0 0.4 0.4 60 1 61 305 88 0 88 0 -0.7 0 -0.4 -0.8 11/30/2004 13:10:00 9.8 0.9 11.8 7.6 9.6 1 12.2 8 0.4 0 0.4 0.4 60 0 60 305 89 0 88 0 -0.8 0 -0.6 -0.8 11/30/2004 13:20:00 10.1 0.8 11.8 8 9.9 0.8 11.5 7.6 0.4 0 0.4 0.4 60 0 61 305 88 0 88 0 -1 0 -0.6 -1.1 11/30/2004 13:30:00 10.2 0.8 11.8 8.4 10 0.8 11.8 8 0.4 0 0.4 0.4 59 0 60 305 86 1 86 0 -1.1 0 -1.1 -1.1 11/30/2004 13:40:00 10.1 0.9 12.2 7.6 9.9 0.9 12.6 7.2 0.4 0 0.4 0.4 58 0 58 305 89 0 88 0 -1 0 -0.6 -1.1 11/30/2004 13:50:00 10.9 1 13.3 8 10.9 1 13.7 8.4 0.4 0 0.4 0.4 57 0 57 305 87 0 87 0 -1.1 0 -0.8 -1.1 11/30/2004 14:00:00 10.9 0.9 13 8.8 10.7 1 13 8.4 0.4 0 0.4 0.4 56 0 56 305 88 0 88 0 -1 0 -0.6 -1.1 11/30/2004 14:10:00 11 0.9 13 9.1 10.7 0.9 13 8.4 0.4 0 0.4 0.4 55 0 56 305 89 0 90 0 -1 0 -0.4 -1.1 11/30/2004 14:20:00 10.6 1 12.6 8.4 10.4 1 12.6 7.6 0.4 0 0.4 0.4 54 0 54 305 88 1 88 0 -1.1 0 -0.6 -1.1 11/30/2004 14:30:00 10.5 0.8 12.6 8.4 10.2 0.8 12.2 8 0.4 0 0.4 0.4 54 0 54 305 86 0 86 0 -1.1 0 -1.1 -1.3 11/30/2004 14:40:00 11.1 1 13 8.4 10.8 1 12.6 8 0.4 0 0.4 0.4 53 0 54 305 84 1 84 0 -1.2 0 -0.6 -1.3 11/30/2004 14:50:00 10.5 1 12.6 7.6 10.2 1 12.6 7.2 0.4 0 0.4 0.4 53 1 54 305 82 0 82 0 -1.4 0 -1.3 -1.5 11/30/2004 15:00:00 11.5 0.8 13 9.1 11.1 0.9 13 8.8 0.4 0 0.4 0.4 54 0 54 305 80 0 80 0 -1.5 0 -0.8 -1.8 11/30/2004 15:10:00 10.9 0.8 12.6 9.1 10.7 0.8 12.6 8.4 0.4 0 0.4 0.4 53 0 53 305 80 1 80 0 -1.5 0 -1.1 -1.8 11/30/2004 15:20:00 10.6 0.8 13 8.8 10.3 0.8 12.6 8.4 0.4 0 0.4 0.4 52 0 52 305 79 0 79 0 -1.5 0 -1.3 -1.8 11/30/2004 15:30:00 9.3 0.8 11.1 7.2 9 0.9 11.1 6.5 0.4 0 0.4 0.4 51 0 51 305 82 0 82 0 -1.4 0 -1.1 -1.5 11/30/2004 15:40:00 9.2 0.9 11.1 7.2 8.9 0.9 10.7 6.5 0.4 0 0.4 0.4 51 1 51 305 81 1 83 0 -1.4 0 -1.1 -1.5 11/30/2004 15:50:00 7.7 0.6 9.5 6.1 7.6 0.7 9.5 5.3 0.4 0 0.4 0.4 52 0 52 305 81 0 80 0 -1.4 0 -1.3 -1.5 11/30/2004 16:00:00 7.3 0.5 8.4 5.7 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 52 1 52 305 81 0 81 0 -1.4 0 -1.1 -1.5 11/30/2004 16:10:00 6.1 0.6 7.2 4.2 6 0.6 7.2 4.2 0.4 0 0.4 0.4 52 1 53 305 83 1 81 0 -1.4 0 -1.1 -1.5 11/30/2004 16:20:00 6.6 0.8 8.4 4.2 6.5 0.9 8.4 3.8 0.4 0 0.4 0.4 51 0 51 305 83 1 84 0 -1.4 0 -1.1 -1.5 11/30/2004 16:30:00 5.5 0.7 7.2 3.8 5.6 0.6 7.2 3.8 0.4 0 0.4 0.4 50 0 50 305 81 0 81 0 -1.5 0 -1.1 -1.8 11/30/2004 16:40:00 5.3 0.6 6.8 3.4 5.3 0.6 6.8 3.4 0.4 0 0.4 0.4 50 0 50 305 81 0 82 0 -1.5 0 -1.1 -1.8 11/30/2004 16:50:00 5.9 0.5 7.2 4.6 5.8 0.5 7.2 4.6 0.4 0 0.4 0.4 49 0 49 305 81 0 81 0 -1.4 0 -1.1 -1.5 11/30/2004 17:00:00 6 0.4 6.8 4.6 6 0.4 6.8 4.6 0.4 0 0.4 0.4 49 0 48 305 82 0 82 0 -1.4 0 -1.3 -1.5 11/30/2004 17:10:00 5.6 0.4 6.5 4.2 5.6 0.4 6.8 4.6 0.4 0 0.4 0.4 47 0 48 305 82 0 82 0 -1.5 0 -1.3 -1.5 11/30/2004 17:20:00 3.8 0.6 6.1 2.3 3.9 0.6 5.7 2.6 0.4 0 0.4 0.4 47 0 47 305 81 1 82 0 -1.6 0 -1.3 -1.8 11/30/2004 17:30:00 4.4 0.4 5.3 3 4.5 0.4 5.3 3 0.4 0 0.4 0.4 47 0 46 305 80 0 80 0 -1.6 0 -1.3 -1.8 11/30/2004 17:40:00 3.8 0.3 4.2 3 3.8 0.3 4.6 2.6 0.4 0 0.4 0.4 46 0 46 305 80 0 80 0 -1.6 0 -1.3 -1.8 11/30/2004 17:50:00 4.2 0.4 4.9 3 4.2 0.5 4.9 3 0.4 0 0.4 0.4 46 0 46 305 80 0 80 0 -1.4 0 -1.1 -1.5 11/30/2004 18:00:00 4.6 0.4 5.3 3.8 4.6 0.4 5.7 3.8 0.4 0 0.4 0.4 46 0 46 305 80 0 80 0 -1.4 0 -1.1 -1.5 11/30/2004 18:10:00 4.5 1 6.8 3 4.6 1 7.2 3 0.4 0 0.4 0.4 46 0 45 305 80 0 80 0 -1.4 0 -1.1 -1.5 11/30/2004 18:20:00 5.8 0.4 6.8 4.6 5.9 0.4 6.8 4.6 0.4 0 0.4 0.4 46 0 45 305 78 1 80 0 -1.6 0 -1.3 -1.8 11/30/2004 18:30:00 5.2 0.4 6.1 4.2 5.3 0.4 6.5 4.6 0.4 0 0.4 0.4 46 0 45 305 76 0 76 0 -1.8 0 -1.5 -2 11/30/2004 18:40:00 5.2 0.4 6.1 4.2 5.3 0.4 6.1 4.2 0.4 0 0.4 0.4 46 0 46 305 74 0 74 0 -1.9 0 -1.8 -2 11/30/2004 18:50:00 4.1 0.4 5.3 3 4.3 0.4 5.3 3.4 0.4 0 0.4 0.4 47 2 48 305 73 0 73 0 -2 0 -1.8 -2 11/30/2004 19:00:00 4.4 0.4 5.3 3.4 4.6 0.4 5.3 3.4 0.4 0 0.4 0.4 51 0 51 305 72 0 73 0 -2.1 0.1 -1.5 -2.2 11/30/2004 19:10:00 4 0.4 4.9 3 4.1 0.4 4.9 3 0.4 0 0.4 0.4 50 0 51 305 72 0 72 0 -2.1 0 -2 -2.2 11/30/2004 19:20:00 4.2 0.4 4.9 3.4 4.3 0.4 5.3 3.4 0.4 0 0.4 0.4 50 0 50 305 72 0 72 0 -2.1 0 -2 -2.2 11/30/2004 19:30:00 3.8 0.4 4.9 3 3.9 0.4 4.6 3 0.4 0 0.4 0.4 53 0 53 305 71 0 72 0 -2.1 0 -2 -2.2 11/30/2004 19:40:00 2.8 0.4 3.8 1.9 3 0.4 3.8 1.9 0.4 0 0.4 0.4 53 0 53 305 71 0 71 0 -2 0 -2 -2.2 11/30/2004 19:50:00 2.3 0.3 3 1.5 2.5 0.3 3 1.9 0.4 0 0.4 0.4 53 0 53 305 71 0 71 0 -1.9 0 -1.8 -2 11/30/2004 20:00:00 2.7 0.6 3.8 1.5 2.9 0.6 3.8 1.5 0.4 0 0.4 0.4 52 0 52 305 71 0 71 0 -1.8 0 -1.5 -2 11/30/2004 20:10:00 3.1 0.4 3.8 2.3 3.2 0.3 4.2 2.6 0.4 0 0.4 0.4 52 0 52 305 71 0 71 0 -1.9 0 -1.3 -2 11/30/2004 20:20:00 2.6 0.3 3 1.9 2.8 0.3 3.4 2.3 0.4 0 0.4 0.4 52 0 52 305 72 0 72 0 -1.9 0 -1.5 -2 11/30/2004 20:30:00 2.3 0.3 3 1.5 2.4 0.3 3 1.5 0.4 0 0.4 0.4 51 0 51 305 72 0 72 0 -1.9 0 -1.5 -2 11/30/2004 20:40:00 1.6 0.3 2.3 1.1 1.7 0.3 2.3 1.1 0.4 0 0.4 0.4 50 0 51 305 71 0 71 0 -2 0.1 -1.5 -2.2 11/30/2004 20:50:00 1.5 0.3 1.9 0.7 1.5 0.2 1.9 1.1 0.4 0 0.4 0.4 50 0 50 305 70 0 71 0 -2.3 0.1 -1.8 -2.7 11/30/2004 21:00:00 0.7 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 49 0 49 305 70 0 70 0 -2.6 0 -2.2 -2.7 11/30/2004 21:10:00 1 0.6 2.3 0.4 1.6 0.7 3 0.4 0.4 0 0.4 0.4 49 0 49 305 70 0 69 0 -2.4 0 -2.2 -2.7 11/30/2004 21:20:00 1.2 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.4 0 0.4 0.4 48 0 48 305 69 0 70 0 -2.6 0.1 -1.8 -2.7 11/30/2004 21:30:00 2.3 0.5 3.4 1.1 2.2 0.4 3 1.1 0.4 0 0.4 0.4 48 0 48 305 69 0 69 0 -2.8 0 -2.4 -2.9 11/30/2004 21:40:00 3.1 0.8 4.6 0.4 2.9 0.8 4.2 0.7 0.4 0 0.4 0.4 48 0 48 305 68 0 68 0 -2.8 0 -2.4 -2.9 11/30/2004 21:50:00 4.5 0.7 5.7 3 4.4 0.7 5.7 3 0.4 0 0.4 0.4 48 0 48 305 69 0 69 0 -2.7 0 -2.2 -2.7 11/30/2004 22:00:00 5.8 0.3 6.8 4.9 5.8 0.3 6.5 4.9 0.4 0 0.4 0.4 48 0 48 305 69 0 69 0 -2.8 0 -2.4 -2.9 11/30/2004 22:10:00 6.1 0.3 7.2 5.3 5.9 0.3 6.8 4.9 0.4 0 0.4 0.4 48 0 48 305 69 0 69 0 -2.8 0 -2.7 -2.9 11/30/2004 22:20:00 6 0.5 7.2 3.4 6 0.4 6.8 4.9 0.4 0 0.4 0.4 48 0 48 305 70 0 69 0 -2.8 0 -2.4 -2.9 11/30/2004 22:30:00 5.8 0.6 7.2 3.4 5.9 0.4 7.2 4.9 0.4 0 0.4 0.4 48 0 48 305 70 0 70 0 -2.7 0 -2.2 -2.7 11/30/2004 22:40:00 6.1 0.5 7.2 3.4 6.1 0.3 6.8 4.9 0.4 0 0.4 0.4 48 0 48 305 69 0 69 0 -2.8 0 -2.4 -3.1 11/30/2004 22:50:00 6 0.9 7.2 3.4 6.4 0.4 7.6 5.3 0.4 0 0.4 0.4 48 0 48 305 70 0 69 0 -2.8 0 -2.4 -3.1 11/30/2004 23:00:00 6.4 0.9 8.8 3.8 6.7 0.5 8.4 5.3 0.4 0 0.4 0.4 48 0 48 305 71 0 71 0 -2.7 0 -2.2 -2.9 11/30/2004 23:10:00 5.2 1.1 8 2.6 6.7 0.6 8.8 5.3 0.4 0 0.4 0.4 48 0 48 305 73 1 72 0 -2.3 0 -2 -2.7 11/30/2004 23:20:00 4.9 1 7.6 2.6 6.8 0.5 8.8 4.9 0.4 0 0.4 0.4 48 0 48 305 74 0 74 0 -2.3 0 -2 -2.7 11/30/2004 23:30:00 4.8 0.9 7.2 3 6.2 0.5 7.6 4.2 0.4 0 0.4 0.4 48 0 48 305 74 0 74 0 -2.6 0 -2.4 -2.7 11/30/2004 23:40:00 4.3 0.9 7.2 2.6 5.9 0.4 7.2 4.2 0.4 0 0.4 0.4 47 0 48 305 73 0 73 0 -2.7 0 -2.4 -2.7 11/30/2004 23:50:00 5.3 0.8 6.8 2.6 5.9 0.5 7.2 4.2 0.4 0 0.4 0.4 48 0 48 305 76 1 76 0 -1.9 0.2 -1.8 -2.7 12/01/2004 00:00:00 5.8 0.4 7.6 4.6 5.8 0.5 7.2 4.9 0.4 0 0.4 0.4 49 0 48 305 79 1 77 0 -1.6 0.1 -1.1 -1.8 12/01/2004 00:10:00 5.3 0.6 7.2 4.2 5.2 0.6 7.2 3.8 0.4 0 0.4 0.4 49 0 49 305 81 0 81 0 -1.5 0 -1.1 -1.8 12/01/2004 00:20:00 5.7 0.5 6.5 4.6 5.3 0.4 6.5 4.2 0.4 0 0.4 0.4 49 0 49 305 82 0 82 0 -1.7 0 -1.3 -2 12/01/2004 00:30:00 5.9 0.4 6.8 4.9 5.3 0.5 6.5 3.8 0.4 0 0.4 0.4 49 1 48 305 81 0 82 0 -2 0 -1.5 -2.2 12/01/2004 00:40:00 4.5 0.7 5.7 2.6 4 0.7 5.3 2.6 0.4 0 0.4 0.4 49 0 48 305 82 0 82 0 -1.9 0 -1.5 -2 12/01/2004 00:50:00 5.8 0.5 7.2 4.2 5.1 0.6 6.5 3.4 0.4 0 0.4 0.4 49 1 51 305 84 1 83 0 -1.4 0.2 -0.8 -2 12/01/2004 01:00:00 6.2 0.4 7.2 4.9 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 49 0 49 305 85 0 85 0 -1.3 0 -1.1 -1.5 12/01/2004 01:10:00 6.8 0.4 8 5.3 6 0.5 7.2 4.6 0.4 0 0.4 0.4 49 0 49 305 85 0 85 0 -1.5 0 -1.1 -1.8 12/01/2004 01:20:00 6.7 0.4 7.6 5.3 6.2 0.5 7.2 4.6 0.4 0 0.4 0.4 49 1 49 305 83 1 84 0 -1.6 0.1 -1.1 -2 12/01/2004 01:30:00 7 0.4 8 6.1 6.5 0.5 7.2 4.9 0.4 0 0.4 0.4 47 0 47 305 81 0 82 0 -2.1 0 -1.8 -2.4 12/01/2004 01:40:00 6.6 0.3 7.6 5.7 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 47 0 47 305 78 0 78 0 -2.4 0 -2.2 -2.7 12/01/2004 01:50:00 6.7 0.4 7.6 5.3 6 0.5 7.2 4.6 0.4 0 0.4 0.4 46 0 46 305 77 0 77 0 -2.3 0 -2 -2.4 12/01/2004 02:00:00 6.5 0.5 7.6 4.9 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 47 0 46 305 77 0 77 0 -2.1 0 -2 -2.2 12/01/2004 02:10:00 6.6 0.4 7.6 5.7 6 0.5 7.2 4.6 0.4 0 0.4 0.4 46 0 46 305 76 0 76 0 -2.2 0 -2 -2.4 12/01/2004 02:20:00 6.5 0.3 7.2 5.7 5.8 0.4 6.8 4.6 0.4 0 0.4 0.4 46 0 46 305 76 0 76 0 -2.3 0 -2 -2.4 12/01/2004 02:30:00 6.4 0.4 7.6 4.9 5.7 0.5 6.8 4.2 0.4 0 0.4 0.4 46 0 46 305 74 0 74 0 -2.4 0 -2.2 -2.7 12/01/2004 02:40:00 6.5 0.4 7.6 5.3 5.7 0.5 7.2 4.6 0.4 0 0.4 0.4 46 0 46 305 74 0 74 0 -2.6 0 -2.4 -2.7 12/01/2004 02:50:00 6.5 0.3 7.2 5.3 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 45 0 45 305 73 0 73 0 -2.6 0 -2.4 -2.7 12/01/2004 03:00:00 6.4 0.4 7.2 5.3 5.8 0.4 6.8 4.6 0.4 0 0.4 0.4 45 0 45 305 72 0 72 0 -2.7 0 -2.2 -2.7 12/01/2004 03:10:00 6.7 0.3 7.6 6.1 6.2 0.4 6.8 4.6 0.4 0 0.4 0.4 46 0 46 305 73 0 73 0 -2.3 0 -1.8 -2.4 12/01/2004 03:20:00 6.5 0.4 7.2 5.3 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 46 0 46 305 73 0 73 0 -2.3 0 -1.8 -2.4 12/01/2004 03:30:00 6.4 0.4 7.6 5.3 5.8 0.4 6.8 4.6 0.4 0 0.4 0.4 46 0 46 305 74 0 74 0 -2.2 0 -1.8 -2.4 12/01/2004 03:40:00 6.6 0.4 7.6 5.7 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 46 0 46 305 75 0 75 0 -2.1 0.1 -1.8 -2.2 12/01/2004 03:50:00 6.9 0.3 8 6.1 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 47 0 47 305 75 0 75 0 -2.1 0 -2 -2.2 12/01/2004 04:00:00 6.8 0.5 8 5.3 6 0.6 7.6 4.2 0.4 0 0.4 0.4 47 0 47 305 75 0 76 0 -2.1 0 -1.8 -2.2 12/01/2004 04:10:00 6.9 0.4 8 5.7 6.1 0.5 7.2 4.6 0.4 0 0.4 0.4 47 0 47 305 76 0 76 0 -2.1 0.1 -1.8 -2.2 12/01/2004 04:20:00 6.4 0.6 7.6 4.6 5.7 0.6 6.8 4.2 0.4 0 0.4 0.4 47 0 47 305 76 0 76 0 -2.1 0 -1.8 -2.2 12/01/2004 04:30:00 6.4 0.5 7.6 5.3 5.7 0.6 7.2 3.8 0.4 0 0.4 0.4 47 1 47 305 76 0 76 0 -2 0 -1.8 -2 12/01/2004 04:40:00 6.2 0.5 7.2 4.9 5.4 0.7 6.8 3.4 0.4 0 0.4 0.4 47 1 47 305 76 0 76 0 -2 0 -1.5 -2 12/01/2004 04:50:00 5.8 0.6 6.8 4.2 4.6 0.7 6.8 3 0.4 0 0.4 0.4 47 1 47 305 75 0 75 0 -2 0 -1.5 -2.2 12/01/2004 05:00:00 7 0.5 8 4.9 6 0.7 7.6 4.2 0.4 0 0.4 0.4 47 0 47 305 74 0 74 0 -2 0 -1.8 -2 12/01/2004 05:10:00 6.8 0.6 8.4 4.9 5.9 0.8 7.6 3.8 0.4 0 0.4 0.4 47 0 47 305 73 0 73 0 -2 0 -2 -2.2 12/01/2004 05:20:00 6.7 0.6 8.4 4.9 5.4 0.9 8 3 0.4 0 0.4 0.4 47 0 48 305 73 0 73 0 -1.9 0 -1.8 -2 12/01/2004 05:30:00 6.8 0.7 8.4 4.6 5.1 0.7 6.8 3 0.4 0 0.4 0.4 47 0 47 305 73 0 73 0 -1.9 0 -1.8 -2 12/01/2004 05:40:00 7.4 1 9.9 4.6 5.6 0.8 8.4 3.4 0.4 0 0.4 0.4 47 0 47 305 73 0 73 0 -2 0 -2 -2.2 12/01/2004 05:50:00 8.1 0.8 9.5 6.1 6 0.7 8 3.4 0.4 0 0.4 0.4 47 0 47 305 72 0 72 0 -2.2 0 -2 -2.2 12/01/2004 06:00:00 8.2 1 10.7 5.3 6.2 1 8.8 3.4 0.4 0 0.4 0.4 48 1 48 305 73 0 73 0 -2.2 0 -1.8 -2.2 12/01/2004 06:10:00 8.3 1 10.3 5.7 6.2 0.8 8.4 4.2 0.4 0 0.4 0.4 49 0 48 305 73 0 72 0 -2.2 0 -1.8 -2.4 12/01/2004 06:20:00 7.9 1.1 10.3 4.9 6 1 8.8 3.4 0.4 0 0.4 0.4 48 0 48 305 73 0 73 0 -2.4 0 -1.8 -2.4 12/01/2004 06:30:00 8.5 1 11.1 5.7 6.5 0.9 8.8 4.2 0.4 0 0.4 0.4 48 0 48 305 73 0 73 0 -2.4 0 -2 -2.7 12/01/2004 06:40:00 8.3 0.9 9.9 4.9 6.5 0.8 9.1 3.8 0.4 0 0.4 0.4 48 0 48 305 73 0 73 0 -2.5 0 -2 -2.7 12/01/2004 06:50:00 7.5 1.1 9.9 4.6 5.8 1 8.4 3.4 0.4 0 0.4 0.4 48 0 48 305 73 0 73 0 -2.5 0 -2 -2.7 12/01/2004 07:00:00 8.6 0.8 10.3 5.3 6.6 0.8 9.1 3.8 0.4 0 0.4 0.4 48 0 48 305 73 0 73 0 -2.5 0 -2 -2.7 12/01/2004 07:10:00 8.8 1 11.1 6.1 6.7 0.8 8.8 4.6 0.4 0 0.4 0.4 48 0 48 305 73 0 73 0 -2.5 0 -2 -2.7 12/01/2004 07:20:00 8.6 1.2 11.1 4.6 6.5 1 9.1 3.4 0.4 0 0.4 0.4 48 0 48 305 72 0 72 0 -2.6 0.1 -2 -2.7 12/01/2004 07:30:00 8.1 1.1 11.1 4.9 6.3 1.1 9.1 3.8 0.4 0 0.4 0.4 48 0 48 305 71 0 71 0 -2.7 0 -2 -2.7 12/01/2004 07:40:00 9.1 0.8 10.7 6.8 7.1 0.9 9.5 4.9 0.4 0 0.4 0.4 47 0 48 305 70 0 69 0 -2.7 0 -2.2 -2.9 12/01/2004 07:50:00 8.7 1.4 11.5 4.2 6.7 1.3 9.9 2.6 0.4 0 0.4 0.4 47 0 47 305 70 0 69 0 -2.8 0 -2.2 -2.9 12/01/2004 08:00:00 8.6 1.1 11.1 4.6 6.8 1.3 9.9 3 0.4 0 0.4 0.4 47 0 48 305 69 0 69 0 -2.8 0 -2.7 -2.9 12/01/2004 08:10:00 8.8 1.2 11.1 6.1 6.8 1 9.5 4.2 0.4 0 0.4 0.4 47 0 47 305 69 0 69 0 -2.8 0 -2.7 -2.9 12/01/2004 08:20:00 8.9 1 11.1 6.1 6.9 1 9.9 4.2 0.4 0 0.4 0.4 47 0 47 305 69 0 69 0 -2.8 0 -2.4 -2.9 12/01/2004 08:30:00 8.8 1.1 11.1 5.3 6.8 1 9.5 4.6 0.4 0 0.4 0.4 47 1 47 305 68 0 68 0 -2.8 0 -2.4 -3.1 12/01/2004 08:40:00 9 1.3 11.8 4.9 7 1.1 9.5 4.2 0.4 0 0.4 0.4 47 0 47 305 67 0 67 0 -2.8 0 -2.2 -2.9 12/01/2004 08:50:00 9.2 1.1 11.1 5.7 7.5 1.1 10.3 4.6 0.4 0 0.4 0.4 47 1 47 305 67 0 67 0 -2.9 0 -2.4 -3.1 12/01/2004 09:00:00 8.9 1.2 11.5 4.9 6.9 1.1 9.9 3.8 0.4 0 0.4 0.4 47 0 47 305 65 0 65 0 -2.9 0 -2.7 -3.1 12/01/2004 09:10:00 9.4 1 11.5 6.1 7.2 0.9 9.9 4.6 0.4 0 0.4 0.4 47 0 47 305 64 0 64 0 -3 0 -2.7 -3.1 12/01/2004 09:20:00 8.8 1 11.1 5.7 6.8 1.1 9.9 3.8 0.4 0 0.4 0.4 47 0 47 305 63 0 63 0 -3 0 -2.9 -3.1 12/01/2004 09:30:00 8.4 1.1 10.7 5.7 6.6 1 9.5 4.2 0.4 0 0.4 0.4 47 0 47 305 63 0 63 0 -3 0 -2.9 -3.1 12/01/2004 09:40:00 8.2 1 11.1 5.3 6.7 1.3 11.5 3.4 0.4 0 0.4 0.4 48 0 48 305 64 0 64 0 -2.9 0 -2.7 -3.1 12/01/2004 09:50:00 8.1 1 10.3 5.3 6.5 1 9.5 3.4 0.4 0 0.4 0.4 49 0 48 305 65 0 65 0 -2.8 0 -2.7 -3.1 12/01/2004 10:00:00 8.2 1.1 10.7 4.2 6.3 0.9 9.9 3.4 0.4 0 0.4 0.4 49 0 49 305 65 0 66 0 -2.8 0 -2.4 -2.9 12/01/2004 10:10:00 9 1 11.1 6.8 6.9 0.9 9.5 4.2 0.4 0 0.4 0.4 49 1 49 305 66 0 66 0 -2.8 0 -2.4 -3.1 12/01/2004 10:20:00 7.8 1.2 10.3 4.2 5.9 1 8.4 3.4 0.4 0 0.4 0.4 49 1 49 305 65 0 66 0 -2.9 0 -2.4 -3.1 12/01/2004 10:30:00 8.2 1.1 10.7 5.7 6.3 0.9 9.1 4.2 0.4 0 0.4 0.4 49 1 49 305 66 0 66 0 -2.8 0 -2.4 -3.1 12/01/2004 10:40:00 8 1 9.9 5.3 6.6 1.2 9.5 3.8 0.4 0 0.4 0.4 50 0 50 305 68 1 69 0 -2.7 0 -2.7 -2.7 12/01/2004 10:50:00 8 1.1 11.1 5.3 6.4 1.1 9.5 3.8 0.4 0 0.4 0.4 153 112 50 305 72 3 75 0 -2.8 0 -2.7 -2.9 12/01/2004 11:00:00 7.8 1.2 9.9 3.8 6.2 1.1 9.5 3 0.4 0 0.4 0.4 262 8 264 305 75 0 75 0 -2.8 0 -2.2 -2.7 12/01/2004 11:10:00 8 0.9 9.9 5.3 6.1 1 9.1 4.2 0.4 0 0.4 0.4 266 6 262 305 76 0 75 0 -2.7 0 -2 -2.9 12/01/2004 11:20:00 7.6 1.3 10.7 3.8 6.3 1.3 9.1 2.3 0.4 0 0.4 0.4 269 12 275 305 77 0 77 0 -2.7 0 -2.2 -2.9 12/01/2004 11:30:00 6.5 1.3 9.9 4.2 5 1.1 8 2.3 0.4 0 0.4 0.4 263 8 275 305 77 0 77 0 -2.8 0 -2.2 -2.9 12/01/2004 11:40:00 8.1 1.4 11.1 4.9 6.7 1.4 10.3 3.8 0.4 0 0.4 0.4 258 7 261 305 77 0 77 0 -2.8 0 -2.2 -2.9 12/01/2004 11:50:00 7.6 1 9.9 4.9 6.2 1 9.5 3.8 0.4 0 0.4 0.4 258 6 266 305 77 0 77 0 -2.8 0 -2.4 -3.1 12/01/2004 12:00:00 7.7 1 9.9 4.9 6 1 8.8 3.4 0.4 0 0.4 0.4 264 7 262 305 77 0 78 0 -2.8 0 -2.4 -2.9 12/01/2004 12:10:00 7.9 1.1 10.3 4.9 6.3 1.1 8.8 3 0.4 0 0.4 0.4 261 8 265 305 78 0 77 0 -2.7 0 -2.2 -2.9 12/01/2004 12:20:00 7.6 1.2 10.3 3.8 5.8 1 9.1 3.4 0.4 0 0.4 0.4 264 8 259 305 78 0 79 0 -2.8 0 -2.2 -2.7 12/01/2004 12:30:00 7.9 1 10.7 4.6 6.4 1.1 9.5 3.8 0.4 0 0.4 0.4 260 7 256 305 77 0 77 0 -2.8 0 -2.2 -2.9 12/01/2004 12:40:00 7.9 1.3 11.1 4.9 6.3 1.2 9.5 3.4 0.4 0 0.4 0.4 268 9 273 305 78 1 78 0 -2.7 0 -2.2 -2.9 12/01/2004 12:50:00 7.7 1.5 11.5 4.6 6.1 1.3 9.9 3.4 0.4 0 0.4 0.4 264 9 268 305 81 2 80 0 -2.7 0 -2.2 -2.7 12/01/2004 13:00:00 8.7 1.3 11.8 5.7 6.7 1.1 9.1 4.2 0.4 0 0.4 0.4 268 8 275 305 87 0 87 0 -2.7 0 -2.7 -2.7 12/01/2004 13:10:00 7.6 1.2 9.9 4.2 5.9 1.1 8.8 3.4 0.4 0 0.4 0.4 266 9 282 305 89 0 90 0 -2.8 0 -2.7 -2.9 12/01/2004 13:20:00 9.1 1 11.5 6.1 7.8 1.1 10.3 4.6 0.4 0 0.4 0.4 252 7 258 305 90 0 90 0 -2.7 0 -2.7 -2.7 12/01/2004 13:30:00 7.1 1.5 10.7 3.4 5.6 1.2 9.1 3 0.4 0 0.4 0.4 265 10 266 305 91 1 92 0 -2.7 0 -2.7 -2.7 12/01/2004 13:40:00 8.5 1.1 11.5 5.3 6.6 0.8 8.8 4.9 0.4 0 0.4 0.4 267 8 258 305 94 1 94 0 -2.8 0 -2.7 -2.9 12/01/2004 13:50:00 8.5 1.4 11.8 4.6 6.6 1.2 9.9 3 0.4 0 0.4 0.4 266 9 268 305 95 0 95 0 -2.8 0 -2.7 -2.9 12/01/2004 14:00:00 8.5 1.2 11.1 4.9 6.7 1.2 9.5 4.2 0.4 0 0.4 0.4 270 7 266 305 97 1 96 0 -2.8 0 -2.7 -2.7 12/01/2004 14:10:00 8.6 1.2 11.1 5.3 6.8 1.1 9.5 3.4 0.4 0 0.4 0.4 271 7 269 305 97 0 96 0 -2.7 0 -2.7 -2.7 12/01/2004 14:20:00 8 0.9 10.7 4.9 6.4 1 9.9 4.2 0.4 0 0.4 0.4 261 9 252 305 99 1 100 0 -2.7 0 -2.7 -2.7 12/01/2004 14:30:00 8.3 1.4 11.5 5.7 6.9 1.2 10.7 4.6 0.4 0 0.4 0.4 255 7 261 305 101 1 101 0 -2.7 0 -2.7 -2.7 12/01/2004 14:40:00 8.7 1.3 12.2 5.7 7.2 1.3 11.1 4.2 0.4 0 0.4 0.4 257 9 246 305 102 1 102 0 -2.8 0 -2.7 -2.9 12/01/2004 14:50:00 9 1 11.5 6.1 7.2 1.1 10.3 4.6 0.4 0 0.4 0.4 269 7 269 305 103 1 103 0 -2.8 0 -2.7 -2.7 12/01/2004 15:00:00 9.8 1.1 12.6 6.5 7.5 1 10.3 4.9 0.4 0 0.4 0.4 266 7 269 305 105 1 107 0 -2.8 0 -2.7 -2.7 12/01/2004 15:10:00 8.2 1.1 10.7 4.9 6.9 1.3 9.5 3.8 0.4 0 0.4 0.4 257 10 255 305 107 1 108 0 -2.8 0 -2.2 -2.9 12/01/2004 15:20:00 8.5 1.3 11.8 4.6 6.8 1.3 11.1 3 0.4 0 0.4 0.4 264 9 258 305 107 1 106 0 -2.7 0 -2.2 -2.7 12/01/2004 15:30:00 8.6 1.5 11.8 4.9 6.9 1.3 9.9 3.8 0.4 0 0.4 0.4 264 8 261 305 107 0 108 0 -2.7 0 -2.2 -2.7 12/01/2004 15:40:00 8.5 1 11.5 5.3 6.6 1.1 9.1 4.2 0.4 0 0.4 0.4 268 8 263 305 107 0 107 0 -2.7 0 -2.2 -2.9 12/01/2004 15:50:00 8.8 1 11.5 6.5 7.2 1 9.5 4.6 0.4 0 0.4 0.4 258 8 256 305 106 1 105 0 -2.7 0 -2.2 -2.7 12/01/2004 16:00:00 9.3 1.2 11.8 6.1 7.5 1.2 10.7 4.6 0.4 0 0.4 0.4 261 8 261 305 102 1 102 0 -2.7 0 -2.2 -2.7 12/01/2004 16:10:00 8.6 1.4 12.6 5.3 7.3 1.5 11.5 3.4 0.4 0 0.4 0.4 275 7 290 305 99 1 99 0 -2.7 0 -2.2 -2.7 12/01/2004 16:20:00 8.9 1 11.5 5.3 7.3 1.1 10.3 4.6 0.4 0 0.4 0.4 275 6 275 305 98 0 99 0 -2.7 0 -2.2 -2.7 12/01/2004 16:30:00 8.7 1 11.5 5.7 7.1 1.2 9.9 4.2 0.4 0 0.4 0.4 273 9 265 305 97 0 97 0 -2.7 0.1 -2.2 -2.7 12/01/2004 16:40:00 7.7 1.6 11.1 3.8 6 1.3 9.5 3.4 0.4 0 0.4 0.4 265 7 263 305 97 0 96 0 -2.6 0.1 -2 -2.7 12/01/2004 16:50:00 8.2 1.2 11.1 4.9 6.8 1.3 10.3 3.8 0.4 0 0.4 0.4 259 7 251 305 97 0 97 0 -2.6 0 -2 -2.7 12/01/2004 17:00:00 9 1 11.5 6.1 7.2 1 9.9 4.6 0.4 0 0.4 0.4 267 9 270 305 97 0 97 0 -2.5 0 -2 -2.7 12/01/2004 17:10:00 8.9 1.4 12.6 5.7 7.4 1.2 10.3 4.6 0.4 0 0.4 0.4 265 10 266 305 96 0 97 0 -2.6 0 -2 -2.7 12/01/2004 17:20:00 7.9 1.1 10.7 4.9 6.4 1 9.5 4.2 0.4 0 0.4 0.4 268 9 272 305 96 0 96 0 -2.6 0 -2.4 -2.7 12/01/2004 17:30:00 8 1.1 10.3 5.3 6.8 1.2 9.5 4.2 0.4 0 0.4 0.4 275 6 281 305 96 0 95 0 -2.7 0 -2.4 -2.7 12/01/2004 17:40:00 6.9 1 8.8 3.8 5.6 1 8 3.4 0.4 0 0.4 0.4 271 8 277 305 96 0 96 0 -2.7 0 -2.4 -2.7 12/01/2004 17:50:00 7.6 1.3 10.7 4.6 6.2 1.1 9.5 3.8 0.4 0 0.4 0.4 273 6 272 305 94 0 94 0 -2.6 0 -2.2 -2.7 12/01/2004 18:00:00 8.1 1 10.3 4.9 6.3 1 9.1 3.4 0.4 0 0.4 0.4 269 7 264 305 95 0 95 0 -2.6 0 -2.4 -2.7 12/01/2004 18:10:00 7 0.9 9.1 4.2 5.9 0.9 8 3.8 0.4 0 0.4 0.4 275 7 277 305 95 0 95 0 -2.6 0.1 -2.4 -2.7 12/01/2004 18:20:00 7 0.8 9.1 4.6 6.1 0.9 8.4 3.8 0.4 0 0.4 0.4 278 6 294 305 95 0 96 0 -2.6 0 -2.4 -2.7 12/01/2004 18:30:00 6.5 1.3 9.9 3.4 5.4 1.3 8.4 2.3 0.4 0 0.4 0.4 273 7 273 305 95 0 95 0 -2.6 0 -2.4 -2.7 12/01/2004 18:40:00 7.1 1.2 9.1 3.4 6.6 1.3 9.1 2.6 0.4 0 0.4 0.4 285 9 288 305 95 1 95 0 -2.7 0 -2.4 -2.7 12/01/2004 18:50:00 6.5 0.9 8.4 4.2 5.6 0.9 7.6 3.8 0.4 0 0.4 0.4 277 6 281 305 95 0 95 0 -2.6 0 -2.4 -2.7 12/01/2004 19:00:00 6 1 8 3.8 5 0.8 6.8 3 0.4 0 0.4 0.4 272 8 263 305 95 0 95 0 -2.6 0 -2.4 -2.7 12/01/2004 19:10:00 6.7 1.1 8.8 3.4 5.3 1 8.4 2.6 0.4 0 0.4 0.4 272 9 275 305 95 0 95 0 -2.6 0 -2.4 -2.7 12/01/2004 19:20:00 4.7 0.7 6.5 3 3.9 0.7 5.7 2.3 0.4 0 0.4 0.4 266 8 267 305 94 0 94 0 -2.7 0 -2.7 -2.7 12/01/2004 19:30:00 5.2 0.8 7.2 3.4 4.4 0.8 6.5 2.6 0.4 0 0.4 0.4 272 11 273 305 93 1 94 0 -2.7 0 -2.4 -2.7 12/01/2004 19:40:00 4.7 0.7 6.1 2.3 4 0.5 5.3 2.3 0.4 0 0.4 0.4 277 15 275 305 90 0 90 0 -2.7 0 -2.2 -2.7 12/01/2004 19:50:00 4.2 0.7 6.1 3 3.9 0.7 5.7 2.3 0.4 0 0.4 0.4 280 8 281 305 89 0 90 0 -2.7 0.1 -2.2 -2.7 12/01/2004 20:00:00 4.8 0.6 6.5 3.4 4.3 0.6 5.3 2.3 0.4 0 0.4 0.4 282 11 269 305 90 0 90 0 -2.6 0 -2.4 -2.7 12/01/2004 20:10:00 4.6 0.6 6.1 3.4 4.5 0.4 5.7 3.4 0.4 0 0.4 0.4 283 6 275 305 92 1 91 0 -2.6 0 -2.4 -2.7 12/01/2004 20:20:00 5 1 6.8 2.6 4.9 0.9 6.8 2.6 0.4 0 0.4 0.4 292 18 294 305 90 2 90 0 -2.6 0 -2.4 -2.7 12/01/2004 20:30:00 4.6 0.7 6.5 3 4.5 0.7 6.1 3 0.4 0 0.4 0.4 291 11 296 305 89 1 90 0 -2.7 0 -2.4 -2.7 12/01/2004 20:40:00 5 1 6.8 3 4.9 1 6.8 2.6 0.4 0 0.4 0.4 290 7 290 305 88 1 87 0 -2.6 0 -2.4 -2.7 12/01/2004 20:50:00 4.6 1 6.5 3 4.4 1 6.5 2.6 0.4 0 0.4 0.4 287 23 293 305 85 2 85 0 -2.6 0 -2.4 -2.7 12/01/2004 21:00:00 4.3 0.4 5.3 3.4 4.4 0.3 5.3 3.8 0.4 0 0.4 0.4 297 41 309 305 81 4 78 0 -2.6 0.1 -2.2 -2.7 12/01/2004 21:10:00 4.4 0.8 6.1 2.6 4.4 0.7 6.1 2.6 0.4 0 0.4 0.4 295 38 303 305 78 3 75 0 -2.7 0 -2.2 -2.7 12/01/2004 21:20:00 4.3 0.7 6.1 2.6 4.4 0.7 5.7 2.6 0.4 0 0.4 0.4 302 32 312 305 75 2 79 0 -2.7 0 -2.2 -2.7 12/01/2004 21:30:00 4.1 0.8 6.1 2.6 4.4 0.7 6.1 3 0.4 0 0.4 0.4 319 6 312 305 81 6 73 0 -2.7 0 -2.2 -2.7 12/01/2004 21:40:00 4.5 0.5 5.7 3.4 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 302 39 305 305 88 3 95 0 -2.8 0 -2.2 -2.9 12/01/2004 21:50:00 4.4 1 6.5 2.3 4.4 1 6.8 2.3 0.4 0 0.4 0.4 295 36 303 305 89 3 92 0 -2.7 0 -2.2 -2.9 12/01/2004 22:00:00 3.3 1 6.5 1.5 3.2 0.9 5.7 1.5 0.4 0 0.4 0.4 289 20 271 305 85 1 82 0 -2.8 0 -2.7 -2.9 12/01/2004 22:10:00 3.9 0.7 6.1 2.6 3.8 0.6 5.7 2.3 0.4 0 0.4 0.4 286 13 285 305 91 2 86 0 -2.8 0 -2.7 -2.9 12/01/2004 22:20:00 2.4 0.6 3.8 0.4 2.4 0.5 3.8 1.1 0.4 0 0.4 0.4 291 12 293 305 92 1 92 0 -2.8 0 -2.7 -3.1 12/01/2004 22:30:00 3.7 0.5 4.9 2.6 3.5 0.5 4.6 2.3 0.4 0 0.4 0.4 288 7 287 305 93 2 94 0 -2.9 0 -2.7 -3.1 12/01/2004 22:40:00 3.7 0.4 4.6 2.6 3.6 0.4 4.2 2.3 0.4 0 0.4 0.4 287 6 283 305 95 1 95 0 -2.8 0 -2.7 -2.9 12/01/2004 22:50:00 3.7 0.6 4.9 2.3 3.6 0.7 4.9 1.9 0.4 0 0.4 0.4 288 29 303 305 93 1 93 0 -2.8 0 -2.7 -2.7 12/01/2004 23:00:00 3.8 0.3 4.6 3 3.7 0.3 4.6 2.6 0.4 0 0.4 0.4 293 22 300 305 94 1 94 0 -2.8 0 -2.7 -2.9 12/01/2004 23:10:00 4 0.4 4.9 3 3.9 0.4 4.9 3 0.4 0 0.4 0.4 295 28 303 305 93 2 94 0 -2.8 0 -2.7 -2.9 12/01/2004 23:20:00 4.1 0.3 4.9 3.4 3.9 0.3 4.9 3 0.4 0 0.4 0.4 290 23 303 305 92 1 93 0 -2.8 0 -2.7 -3.1 12/01/2004 23:30:00 3.8 0.3 4.6 3 3.7 0.3 4.2 3 0.4 0 0.4 0.4 294 14 285 305 94 3 92 0 -3 0 -2.9 -3.1 12/01/2004 23:40:00 3.1 0.6 4.2 1.5 3 0.6 4.6 1.5 0.4 0 0.4 0.4 297 22 293 305 95 3 98 0 -3.1 0 -2.9 -3.3 12/01/2004 23:50:00 3 0.4 4.2 2.3 2.9 0.4 3.8 1.9 0.4 0 0.4 0.4 288 11 283 305 94 1 95 0 -3.1 0 -2.9 -3.3 12/02/2004 00:00:00 2.8 0.5 3.8 1.9 2.7 0.5 3.8 1.1 0.4 0 0.4 0.4 293 38 291 305 92 2 93 0 -3.1 0.1 -2.7 -3.3 12/02/2004 00:10:00 2.5 0.4 3.4 1.5 2.5 0.4 3.8 1.5 0.4 0 0.4 0.4 296 38 302 305 91 2 88 0 -3.2 0.1 -2.7 -3.3 12/02/2004 00:20:00 2.4 0.5 3.8 1.5 2.5 0.5 3.4 1.5 0.4 0 0.4 0.4 320 28 297 305 89 2 93 0 -3.1 0 -2.4 -3.3 12/02/2004 00:30:00 1.8 0.5 3 0.7 1.9 0.5 3 0.7 0.4 0 0.4 0.4 320 9 322 305 88 0 87 0 -3 0.1 -2.4 -3.3 12/02/2004 00:40:00 2.3 0.4 3.8 1.5 2.4 0.4 3.8 1.5 0.4 0 0.4 0.4 332 7 345 305 87 0 87 0 -3 0 -2.4 -3.3 12/02/2004 00:50:00 3.2 0.4 4.2 2.3 3.4 0.4 4.6 2.3 0.4 0 0.4 0.4 335 12 343 305 87 0 87 0 -2.9 0 -2.4 -3.1 12/02/2004 01:00:00 2.7 0.5 4.2 1.5 2.9 0.6 4.2 1.5 0.4 0 0.4 0.4 337 12 345 305 89 0 89 0 -2.8 0 -2.4 -3.1 12/02/2004 01:10:00 2.3 0.9 4.6 0.7 2.5 0.8 4.6 1.1 0.4 0 0.4 0.4 331 10 319 305 90 0 90 0 -3 0 -2.4 -3.1 12/02/2004 01:20:00 2.3 0.7 3.8 1.5 2.4 0.7 4.2 1.5 0.4 0 0.4 0.4 334 9 333 305 89 0 89 0 -3.1 0.1 -2.4 -3.3 12/02/2004 01:30:00 2.5 0.6 4.2 1.1 2.7 0.6 3.8 1.5 0.4 0 0.4 0.4 342 9 341 305 90 0 90 0 -2.9 0 -2.4 -3.1 12/02/2004 01:40:00 2 0.6 3 0.7 2.1 0.5 3.4 1.1 0.4 0 0.4 0.4 358 10 358 305 91 0 91 0 -2.8 0 -2.2 -2.9 12/02/2004 01:50:00 4.6 1.5 6.8 1.5 4.7 1.5 6.8 1.5 0.4 0 0.4 0.4 346 8 338 305 92 1 92 0 -2.6 0.1 -2 -2.7 12/02/2004 02:00:00 5.6 0.5 6.8 4.6 5.9 0.6 7.2 4.6 0.4 0 0.4 0.4 349 4 356 305 95 0 94 0 -2.4 0 -2 -2.7 12/02/2004 02:10:00 4.9 0.6 6.5 3.4 5.1 0.6 6.5 3.4 0.4 0 0.4 0.4 346 7 341 305 95 0 95 0 -2.5 0 -2 -2.7 12/02/2004 02:20:00 5.2 0.8 6.8 3.8 5.4 0.8 7.2 3.8 0.4 0 0.4 0.4 342 9 336 305 97 0 97 0 -2.6 0 -2 -2.7 12/02/2004 02:30:00 5.8 0.5 6.8 4.6 6 0.5 6.8 4.9 0.4 0 0.4 0.4 341 9 330 305 97 0 96 0 -2.7 0 -2 -2.7 12/02/2004 02:40:00 6.3 0.5 8 5.3 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 331 5 335 305 97 0 97 0 -2.8 0 -2.7 -2.9 12/02/2004 02:50:00 5.6 0.5 6.8 4.6 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 335 7 332 305 96 0 96 0 -3 0 -2.7 -3.1 12/02/2004 03:00:00 4.5 1 6.5 2.3 4.6 1.1 6.8 2.3 0.4 0 0.4 0.4 329 9 326 305 95 0 95 0 -3.1 0 -2.9 -3.3 12/02/2004 03:10:00 4.5 0.7 6.1 3 4.5 0.7 6.1 3.4 0.4 0 0.4 0.4 313 24 306 305 94 1 93 0 -3.3 0 -3.1 -3.3 12/02/2004 03:20:00 5.3 0.4 6.1 4.2 5.4 0.4 6.5 4.6 0.4 0 0.4 0.4 314 24 318 305 93 1 93 0 -3.3 0 -3.3 -3.6 12/02/2004 03:30:00 4.5 0.5 6.1 3.4 4.6 0.5 6.1 3.4 0.4 0 0.4 0.4 317 15 322 305 94 1 94 0 -3.3 0 -3.3 -3.6 12/02/2004 03:40:00 4.7 0.4 5.7 3.8 4.8 0.5 5.7 3.4 0.4 0 0.4 0.4 329 17 331 305 94 0 94 0 -3.3 0 -3.1 -3.3 12/02/2004 03:50:00 4 0.5 5.3 2.6 4.1 0.5 5.3 3 0.4 0 0.4 0.4 329 7 329 305 94 0 94 0 -3.3 0 -3.1 -3.3 12/02/2004 04:00:00 3.9 0.4 4.6 3 4 0.4 4.9 3 0.4 0 0.4 0.4 328 6 329 305 95 0 94 0 -3.2 0 -3.1 -3.3 12/02/2004 04:10:00 3.5 0.3 4.6 2.6 3.6 0.3 4.6 2.6 0.4 0 0.4 0.4 323 6 319 305 96 0 96 0 -3 0 -2.9 -3.1 12/02/2004 04:20:00 5 0.9 7.2 3 5.2 0.9 7.6 2.6 0.4 0 0.4 0.4 332 6 329 305 98 1 98 0 -2.7 0.1 -2.4 -2.9 12/02/2004 04:30:00 5.3 0.6 6.8 3.8 5.5 0.6 7.2 4.2 0.4 0 0.4 0.4 349 10 346 305 102 1 103 0 -2.4 0 -2.2 -2.7 12/02/2004 04:40:00 6.7 0.8 8 4.6 6.9 0.9 8.8 4.6 0.4 0 0.4 0.4 347 12 358 305 104 0 103 0 -2.2 0 -2 -2.4 12/02/2004 04:50:00 6 0.5 7.2 4.2 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 352 7 359 305 105 0 105 0 -2.4 0 -2 -2.4 12/02/2004 05:00:00 5.8 0.5 6.5 4.6 6 0.5 6.8 4.9 0.4 0 0.4 0.4 0 5 3 305 105 0 105 0 -2.4 0 -2.2 -2.4 12/02/2004 05:10:00 7 0.8 8.8 5.3 7.2 0.8 9.1 5.3 0.4 0 0.4 0.4 354 6 359 305 107 0 106 0 -2.3 0 -2.2 -2.7 12/02/2004 05:20:00 7.7 0.8 9.1 6.1 8 0.8 9.9 6.1 0.4 0 0.4 0.4 357 4 355 305 109 1 109 0 -2.1 0 -2 -2.2 12/02/2004 05:30:00 7.2 0.7 8.8 5.3 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 2 9 3 305 110 1 111 0 -2 0 -1.8 -2.2 12/02/2004 05:40:00 7.3 0.8 8.8 5.3 7.5 0.8 9.1 4.9 0.4 0 0.4 0.4 9 7 14 305 112 0 111 0 -1.9 0 -1.8 -2 12/02/2004 05:50:00 7.5 0.7 9.5 5.3 7.6 0.8 9.9 5.7 0.4 0 0.4 0.4 11 8 6 305 113 0 113 0 -2 0 -1.8 -2.2 12/02/2004 06:00:00 8.9 0.6 10.3 7.2 9.2 0.6 10.3 7.2 0.4 0 0.4 0.4 15 3 16 305 113 0 113 0 -1.9 0.1 -1.8 -2.2 12/02/2004 06:10:00 8.4 0.7 9.9 6.8 8.6 0.8 10.3 6.8 0.4 0 0.4 0.4 17 3 21 305 112 0 112 0 -2.2 0 -2 -2.2 12/02/2004 06:20:00 8.7 0.7 10.7 6.8 8.8 0.7 10.7 7.2 0.4 0 0.4 0.4 21 3 15 305 111 0 111 0 -2.1 0 -2 -2.2 12/02/2004 06:30:00 8.5 0.8 10.7 6.8 8.7 0.8 11.1 6.8 0.4 0 0.4 0.4 18 6 13 305 111 0 111 0 -1.9 0 -1.8 -2 12/02/2004 06:40:00 8.1 0.7 9.9 6.5 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 20 6 21 305 112 0 112 0 -1.7 0 -1.8 -1.8 12/02/2004 06:50:00 8 0.6 9.1 6.5 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 23 5 17 305 114 1 113 0 -1.6 0 -1.3 -1.8 12/02/2004 07:00:00 8.4 0.6 9.5 6.8 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 26 5 28 305 114 0 115 0 -1.4 0 -1.3 -1.5 12/02/2004 07:10:00 8.6 0.5 9.5 6.8 8.8 0.6 9.9 6.8 0.4 0 0.4 0.4 17 4 16 305 114 0 113 0 -1.4 0 -1.1 -1.5 12/02/2004 07:20:00 7.4 0.5 8.8 6.1 7.5 0.5 9.1 6.1 0.4 0 0.4 0.4 15 3 13 305 111 1 110 0 -1.3 0 -1.1 -1.3 12/02/2004 07:30:00 6.6 0.6 8.4 5.7 6.8 0.6 8.4 5.7 0.4 0 0.4 0.4 9 5 2 305 112 1 111 0 -1.2 0 -1.1 -1.3 12/02/2004 07:40:00 7.5 0.5 8.8 6.1 7.7 0.6 8.8 6.5 0.4 0 0.4 0.4 6 4 3 305 112 3 114 0 -1.1 0 -1.1 -1.3 12/02/2004 07:50:00 6.8 0.6 8.8 5.3 7 0.6 8.8 5.3 0.4 0 0.4 0.4 6 4 355 305 108 0 107 0 -1.1 0 -1.1 -1.1 12/02/2004 08:00:00 7.1 0.5 8.4 5.7 7.3 0.6 8.8 6.1 0.4 0 0.4 0.4 5 8 4 305 112 3 114 0 -1 0 -0.8 -1.1 12/02/2004 08:10:00 7.9 1.9 12.2 5.7 8 1.8 12.6 5.7 0.4 0 0.4 0.4 0 9 10 305 116 1 117 0 -1.2 0.1 -1.1 -1.8 12/02/2004 08:20:00 13.2 1.1 15.3 9.1 13.4 1.1 16.1 9.5 0.4 0 0.4 0.4 3 3 2 305 116 0 116 0 -2 0.2 -1.5 -2.4 12/02/2004 08:30:00 13.9 0.8 15.6 11.1 14.3 0.8 16.4 11.5 0.4 0 0.4 0.4 5 3 3 305 116 0 115 0 -2.6 0.1 -2.2 -2.9 12/02/2004 08:40:00 13.2 1.1 15.3 9.9 13.5 1.1 16.1 10.3 0.4 0 0.7 0.4 6 5 2 305 115 0 116 0 -2.9 0 -2.7 -3.1 12/02/2004 08:50:00 13.8 1 16.1 10.7 14.1 0.9 16.1 11.5 0.4 0 0.4 0.4 8 4 8 305 115 0 114 0 -3.2 0.1 -2.7 -3.3 12/02/2004 09:00:00 14.7 1 16.8 12.2 15 1.1 17.6 12.6 0.4 0 0.4 0.4 8 4 9 305 114 0 114 0 -3.4 0 -3.1 -3.8 12/02/2004 09:10:00 14.2 1.1 16.8 10.7 14.5 1.2 17.2 11.1 0.4 0 0.4 0.4 11 4 8 305 113 0 114 0 -3.5 0 -3.3 -3.8 12/02/2004 09:20:00 14.5 1 17.2 12.2 14.9 1.1 17.6 11.8 0.4 0 0.4 0.4 9 4 7 305 113 0 113 0 -3.8 0 -3.6 -3.8 12/02/2004 09:30:00 14.5 1 16.8 12.2 14.8 1 17.2 12.2 0.4 0 0.4 0.4 10 4 9 305 112 0 112 0 -4.1 0.1 -3.8 -4.2 12/02/2004 09:40:00 14.4 1 16.4 11.8 14.6 1.1 17.2 11.5 0.4 0 0.4 0.4 10 4 17 305 112 0 112 0 -4.1 0 -4 -4.5 12/02/2004 09:50:00 14.5 1.2 17.2 11.1 14.8 1.2 17.2 11.8 0.4 0 0.4 0.4 8 4 13 305 111 0 111 0 -4.4 0 -4.2 -4.5 12/02/2004 10:00:00 14.6 1.5 17.6 9.9 14.8 1.6 18.3 9.9 0.4 0 0.4 0.4 4 6 0 305 111 0 111 0 -4.6 0.1 -4 -4.7 12/02/2004 10:10:00 15 1 16.8 11.5 15.4 1.1 17.6 12.2 0.4 0 0.7 0.4 2 4 357 305 110 0 110 0 -4.9 0 -4.5 -4.9 12/02/2004 10:20:00 14.6 1 16.8 11.1 14.9 1.1 17.6 11.1 0.4 0 0.4 0.4 5 4 11 305 110 0 111 0 -4.9 0 -4.5 -5.1 12/02/2004 10:30:00 14.3 1 16.8 11.8 14.6 1 17.6 11.8 0.4 0 0.4 0.4 6 5 4 305 110 0 109 0 -5 0 -4.7 -5.1 12/02/2004 10:40:00 13.8 0.9 16.8 11.5 14.1 1 17.2 11.1 0.4 0 0.4 0.4 5 6 13 305 110 0 110 0 -5 0 -4.5 -5.3 12/02/2004 10:50:00 13.9 1 16.1 11.1 14.1 1.1 16.4 11.5 0.4 0 0.4 0.4 7 4 6 305 109 0 109 0 -5.2 0.1 -4.7 -5.6 12/02/2004 11:00:00 13.4 1.2 16.4 9.9 13.6 1.3 16.8 10.3 0.4 0 0.4 0.4 6 6 13 305 109 0 109 0 -5.3 0.1 -5.1 -5.6 12/02/2004 11:10:00 13.7 1.1 16.4 10.7 14 1.1 16.8 11.1 0.4 0 0.4 0.4 3 5 4 305 108 0 108 0 -5.5 0 -5.1 -5.8 12/02/2004 11:20:00 13.5 1.3 16.8 9.5 13.9 1.3 16.8 10.3 0.4 0 0.4 0.4 1 5 359 305 108 0 108 0 -5.5 0 -5.3 -5.8 12/02/2004 11:30:00 13.7 1.2 16.4 10.3 14 1.3 16.8 10.7 0.4 0 0.4 0.4 4 4 3 305 108 0 108 0 -5.6 0 -5.6 -5.8 12/02/2004 11:40:00 14.5 1 16.8 11.5 14.8 1 17.2 11.8 0.4 0 0.4 0.4 1 4 2 305 107 0 107 0 -5.7 0 -5.6 -5.8 12/02/2004 11:50:00 13.8 0.9 15.6 11.1 14.2 1 16.8 11.5 0.4 0 0.4 0.4 3 5 0 305 108 0 108 0 -5.7 0 -5.6 -5.8 12/02/2004 12:00:00 13.7 1.3 16.4 10.7 14 1.5 17.2 10.7 0.4 0 0.4 0.4 4 5 1 305 108 0 108 0 -5.7 0 -5.6 -5.8 12/02/2004 12:10:00 14.7 1 17.2 12.2 14.9 1.2 17.6 11.1 0.4 0 0.4 0.4 5 4 4 305 108 0 108 0 -5.8 0 -5.6 -5.8 12/02/2004 12:20:00 14 1.3 16.8 10.7 14.3 1.3 17.2 10.7 0.4 0 0.4 0.4 5 5 5 305 109 0 109 0 -5.7 0 -5.6 -5.8 12/02/2004 12:30:00 14.1 1.1 16.4 11.5 14.3 1.2 17.2 11.1 0.4 0 0.4 0.4 7 5 12 305 108 0 108 0 -5.8 0 -5.6 -6 12/02/2004 12:40:00 13.9 1.1 16.1 11.1 14.2 1.1 16.4 10.3 0.4 0 0.4 0.4 6 5 2 305 109 0 108 0 -5.7 0 -5.6 -5.8 12/02/2004 12:50:00 14.5 0.9 16.4 11.5 14.7 1 17.2 11.5 0.4 0 0.4 0.4 5 5 5 305 109 0 109 0 -5.7 0 -5.6 -6 12/02/2004 13:00:00 14.3 1 16.4 11.1 14.5 1.2 17.2 11.1 0.4 0 0.4 0.4 6 5 7 305 109 0 109 0 -5.7 0 -5.6 -6 12/02/2004 13:10:00 14.9 1 17.6 12.6 15.3 1.1 17.9 12.2 0.4 0 0.4 0.4 3 3 1 305 110 0 110 0 -5.8 0.1 -5.6 -6 12/02/2004 13:20:00 14.6 1 17.2 11.5 14.8 1.1 17.6 11.5 0.4 0 0.4 0.4 8 5 8 305 110 0 110 0 -5.7 0 -5.6 -6 12/02/2004 13:30:00 14.6 1.2 17.2 11.1 14.8 1.3 17.9 11.1 0.4 0 0.4 0.4 3 5 4 305 110 0 110 0 -5.8 0 -5.6 -6 12/02/2004 13:40:00 15.3 1.1 17.6 11.8 15.5 1.2 17.9 11.8 0.4 0 0.4 0.4 4 4 5 305 110 0 110 0 -5.9 0.1 -5.6 -6 12/02/2004 13:50:00 15.6 1.3 18.7 11.8 15.7 1.3 18.3 12.2 0.4 0 0.4 0.4 3 6 356 305 110 0 110 0 -5.8 0 -5.3 -6 12/02/2004 14:00:00 16.1 1.3 18.7 12.2 16.4 1.3 19.1 12.6 0.4 0 0.4 0.4 358 5 356 305 110 0 109 0 -5.9 0 -5.8 -6.2 12/02/2004 14:10:00 16.4 1.4 19.5 11.1 16.6 1.5 19.9 12.2 0.4 0 0.4 0.4 0 4 358 305 110 0 110 0 -6.1 0 -6 -6.4 12/02/2004 14:20:00 15.9 1.1 18.7 12.6 16.1 1.3 18.7 11.8 0.4 0 0.4 0.4 359 5 4 305 110 0 110 0 -6.2 0 -6 -6.4 12/02/2004 14:30:00 16.6 1 19.1 13.7 16.7 1.1 19.9 13.7 0.4 0 0.4 0.4 356 4 352 305 110 0 111 0 -6.2 0 -6 -6.4 12/02/2004 14:40:00 17 1 19.1 13.7 17.2 1 20.6 14.5 0.4 0 0.4 0.4 356 4 356 305 110 0 111 0 -6.3 0 -6.2 -6.4 12/02/2004 14:50:00 16.5 1.2 19.5 12.6 16.8 1.3 19.9 13 0.4 0 0.4 0.4 356 5 8 305 110 0 111 0 -6.4 0 -6.2 -6.7 12/02/2004 15:00:00 15.7 1.3 18.3 12.2 15.9 1.3 18.7 12.6 0.4 0 0.4 0.4 357 4 358 305 110 0 111 0 -6.4 0.1 -6.2 -6.7 12/02/2004 15:10:00 15.6 1 17.9 12.2 15.8 1.1 18.7 12.6 0.4 0 0.4 0.4 359 5 359 305 110 0 111 0 -6.5 0 -6 -6.7 12/02/2004 15:20:00 15.5 1.1 18.3 12.2 15.7 1.2 18.3 12.2 0.4 0 0.4 0.4 356 4 355 305 110 0 110 0 -6.7 0 -6.7 -6.9 12/02/2004 15:30:00 14.6 1.1 17.2 11.5 14.8 1.1 17.6 11.8 0.4 0 0.4 0.4 358 5 6 305 110 0 110 0 -6.7 0 -6.7 -6.9 12/02/2004 15:40:00 14.8 1.3 17.9 11.5 15.1 1.3 17.9 11.1 0.4 0 0.4 0.4 358 6 1 305 110 0 111 0 -6.8 0 -6.7 -6.9 12/02/2004 15:50:00 15 1.4 17.6 11.1 15.3 1.4 17.9 11.5 0.4 0 0.4 0.4 354 6 351 305 111 0 111 0 -6.5 0 -6.2 -6.7 12/02/2004 16:00:00 16.3 1.2 18.7 13 16.4 1.3 19.1 12.2 0.4 0 0.4 0.4 358 5 349 305 111 0 111 0 -6.7 0 -6.7 -6.9 12/02/2004 16:10:00 15.8 1.1 18.3 12.6 16 1.2 19.1 12.6 0.4 0 0.4 0.4 357 4 354 305 111 0 111 0 -6.6 0 -6.2 -6.9 12/02/2004 16:20:00 14.9 1.3 17.9 11.5 15.2 1.3 18.7 11.1 0.4 0 0.4 0.4 357 5 6 305 112 0 112 0 -6.4 0 -6.2 -6.7 12/02/2004 16:30:00 14.8 1.1 17.2 11.8 15 1.1 17.6 12.6 0.4 0 0.4 0.4 359 4 355 305 112 0 111 0 -6.7 0 -6.7 -6.9 12/02/2004 16:40:00 15.3 1.2 17.6 12.2 15.6 1.2 17.9 12.2 0.4 0 0.4 0.4 357 5 355 305 112 0 112 0 -6.8 0 -6.7 -6.9 12/02/2004 16:50:00 14.1 1 16.8 11.1 14.4 1.2 17.2 10.7 0.4 0 0.4 0.4 357 5 347 305 111 0 111 0 -6.7 0 -6.7 -6.9 12/02/2004 17:00:00 14.1 1.2 17.2 10.7 14.4 1.2 17.6 11.5 0.4 0 0.4 0.4 1 6 357 305 111 0 111 0 -6.7 0 -6.4 -6.9 12/02/2004 17:10:00 13.9 0.9 16.1 11.5 14.2 1 17.2 11.5 0.4 0 0.4 0.4 2 5 3 305 111 0 111 0 -6.9 0 -6.7 -6.9 12/02/2004 17:20:00 13.7 1 16.8 10.3 14 1.1 16.4 10.7 0.4 0 0.4 0.4 359 4 1 305 111 0 111 0 -6.8 0 -6.7 -6.9 12/02/2004 17:30:00 13.5 1 16.1 10.7 13.7 1.1 16.4 11.1 0.4 0 0.4 0.4 2 5 2 305 111 0 111 0 -6.8 0 -6.7 -6.9 12/02/2004 17:40:00 13.4 0.9 15.6 11.1 13.6 1 15.6 9.9 0.4 0 0.4 0.4 1 5 0 305 110 1 109 0 -6.7 0 -6.7 -6.9 12/02/2004 17:50:00 13.5 1.2 16.1 10.3 13.8 1.2 16.8 10.3 0.4 0 0.4 0.4 359 5 4 305 109 0 109 0 -6.7 0 -6.4 -6.9 12/02/2004 18:00:00 13.4 1 16.1 9.9 13.8 1 16.4 11.5 0.4 0 0.4 0.4 359 5 353 305 109 0 109 0 -6.7 0 -6.7 -6.9 12/02/2004 18:10:00 12.7 0.8 14.9 10.3 13 0.8 14.9 10.7 0.4 0 0.4 0.4 0 5 7 305 109 0 109 0 -6.5 0 -6.4 -6.7 12/02/2004 18:20:00 12.3 1.1 15.6 9.5 12.5 1.1 15.6 9.5 0.4 0 0.4 0.4 356 5 0 305 109 0 109 0 -6.5 0 -6.4 -6.9 12/02/2004 18:30:00 12.1 1 14.5 9.5 12.4 1 14.9 10.3 0.4 0 0.4 0.4 355 5 5 305 109 0 109 0 -6.5 0 -6.2 -6.9 12/02/2004 18:40:00 12.4 1 15.3 9.9 12.7 1 15.6 10.3 0.4 0 0.4 0.4 357 6 0 305 109 0 109 0 -6.6 0 -6.4 -6.9 12/02/2004 18:50:00 13.3 0.9 15.3 10.3 13.7 1 16.1 10.7 0.4 0 0.4 0.4 356 4 354 305 109 0 109 0 -6.7 0 -6.2 -6.9 12/02/2004 19:00:00 13.7 1.1 16.4 11.1 14 1.2 16.4 10.3 0.4 0 0.4 0.4 356 4 355 305 109 0 109 0 -6.6 0 -6.4 -6.9 12/02/2004 19:10:00 13.5 1 16.1 10.3 13.8 1.2 16.4 10.7 0.4 0 0.4 0.4 358 5 0 305 109 0 109 0 -6.7 0 -6.7 -6.9 12/02/2004 19:20:00 12.5 1 15.3 9.5 12.8 1.1 16.1 9.9 0.4 0 0.4 0.4 0 6 351 305 109 0 109 0 -6.6 0 -6.4 -6.9 12/02/2004 19:30:00 12.7 0.8 14.5 10.7 13 0.8 14.5 10.7 0.4 0 0.4 0.4 356 5 354 305 109 0 109 0 -6.5 0 -6.2 -6.7 12/02/2004 19:40:00 13.3 0.9 15.6 11.1 13.5 1 16.4 10.3 0.4 0 0.4 0.4 0 5 16 305 109 0 108 0 -6.5 0 -6.4 -6.7 12/02/2004 19:50:00 13.1 1.1 15.3 9.5 13.4 1.2 15.6 9.5 0.4 0 0.4 0.4 358 5 355 305 108 0 108 0 -6.5 0.1 -6.2 -6.9 12/02/2004 20:00:00 12.6 1.1 15.3 9.5 12.9 1.1 15.6 9.1 0.4 0 0.4 0.4 355 4 349 305 108 0 108 0 -6.5 0 -6.2 -6.7 12/02/2004 20:10:00 12.9 0.9 14.5 10.3 13.1 1 15.3 9.9 0.4 0 0.4 0.4 355 5 350 305 108 0 108 0 -6.5 0 -6 -6.7 12/02/2004 20:20:00 12.9 0.8 15.3 10.7 13.2 0.8 15.3 11.1 0.4 0 0.4 0.4 357 6 2 305 107 0 107 0 -6.7 0.1 -6.4 -6.9 12/02/2004 20:30:00 12.8 1 14.5 10.3 13 1 16.1 9.9 0.4 0 0.4 0.4 356 5 358 305 107 0 107 0 -6.8 0 -6.2 -7.1 12/02/2004 20:40:00 12.9 0.8 14.9 10.3 13.3 0.9 14.9 10.3 0.4 0 0.4 0.4 357 5 358 305 106 0 106 0 -6.8 0.1 -6.7 -7.1 12/02/2004 20:50:00 12.6 1.1 14.9 8.8 12.9 1.2 15.3 9.1 0.4 0 0.4 0.4 358 4 3 305 105 0 105 0 -6.9 0 -6.7 -7.1 12/02/2004 21:00:00 12.4 0.9 14.5 9.5 12.6 1 15.3 9.5 0.4 0 0.4 0.4 356 5 0 305 105 0 105 0 -7 0 -6.9 -7.3 12/02/2004 21:10:00 12.4 0.9 14.1 9.9 12.8 0.9 14.9 9.9 0.4 0 0.4 0.4 357 4 354 305 105 0 105 0 -7.1 0 -6.9 -7.3 12/02/2004 21:20:00 12.4 1.2 15.3 9.5 12.7 1.3 15.3 9.5 0.4 0 0.4 0.4 359 5 3 305 105 0 105 0 -7.1 0 -6.9 -7.3 12/02/2004 21:30:00 12.3 0.8 14.9 10.3 12.5 0.7 14.1 10.7 0.4 0 0.4 0.4 357 4 351 305 105 0 105 0 -7.1 0 -6.9 -7.3 12/02/2004 21:40:00 12.9 0.9 14.9 9.9 13.2 1 15.6 10.3 0.4 0 0.4 0.4 358 5 355 305 105 0 105 0 -7.3 0 -7.1 -7.5 12/02/2004 21:50:00 12.3 0.8 14.1 10.3 12.6 0.9 14.9 9.5 0.4 0 0.4 0.4 355 5 352 305 104 0 104 0 -7.3 0 -7.1 -7.5 12/02/2004 22:00:00 12 0.8 14.1 9.9 12.3 0.9 14.5 10.3 0.4 0 0.4 0.4 357 5 359 305 104 0 104 0 -7.2 0 -7.1 -7.3 12/02/2004 22:10:00 11.9 1.1 14.5 9.5 12.3 1.1 14.9 9.9 0.4 0 0.4 0.4 358 5 0 305 104 0 103 0 -7.4 0 -7.1 -7.5 12/02/2004 22:20:00 11.9 0.9 14.1 9.1 12.2 1 15.3 9.1 0.4 0 0.4 0.4 354 5 358 305 103 0 103 0 -7.2 0 -7.1 -7.5 12/02/2004 22:30:00 11 1 13.3 8.4 11.3 1.1 14.1 8.4 0.4 0 0.4 0.4 355 6 354 305 103 0 103 0 -7.2 0 -6.9 -7.3 12/02/2004 22:40:00 10.6 1 13 8 10.9 1 13.3 8.4 0.4 0 0.4 0.4 351 5 345 305 103 0 103 0 -7.2 0 -6.9 -7.3 12/02/2004 22:50:00 11 0.9 13 8.8 11.4 1 13.3 9.1 0.4 0 0.4 0.4 348 5 347 305 104 0 103 0 -7.1 0 -6.9 -7.3 12/02/2004 23:00:00 10.7 0.8 13 8.4 11.1 0.9 13.3 8.8 0.4 0 0.4 0.4 350 8 359 305 103 0 103 0 -7.1 0 -7.1 -7.3 12/02/2004 23:10:00 11.1 0.8 13.7 8.4 11.5 0.9 13.7 9.1 0.4 0 0.4 0.4 349 7 350 305 103 0 103 0 -7.1 0 -6.9 -7.3 12/02/2004 23:20:00 11.4 1 14.5 9.1 11.7 1 14.9 8.8 0.4 0 0.4 0.4 348 5 347 305 103 0 103 0 -7.3 0 -7.1 -7.5 12/02/2004 23:30:00 10.4 1 13 8 10.8 1.1 13.7 7.6 0.4 0 0.4 0.4 351 5 348 305 103 0 103 0 -7.4 0 -6.9 -7.5 12/02/2004 23:40:00 10.3 1 12.2 7.6 10.7 1.1 13.3 7.6 0.4 0 0.4 0.4 345 5 352 305 102 0 102 0 -7.3 0 -7.1 -7.5 12/02/2004 23:50:00 9.4 1 11.5 6.5 9.7 1 11.8 6.8 0.4 0 0.4 0.4 350 5 347 305 101 0 101 0 -7.4 0 -7.3 -7.5 12/03/2004 00:00:00 9 0.8 11.1 6.8 9.3 0.9 11.8 6.8 0.4 0 0.4 0.4 335 8 345 305 100 0 101 0 -7.5 0 -6.9 -7.7 12/03/2004 00:10:00 8 0.9 9.9 4.2 8.2 1 10.3 4.6 0.4 0 0.4 0.4 337 9 312 305 100 0 100 0 -7.5 0 -6.9 -7.7 12/03/2004 00:20:00 8.4 0.9 10.3 5.7 8.6 1 11.1 5.7 0.4 0 0.4 0.4 334 8 339 305 100 0 100 0 -7.5 0.1 -6.9 -7.7 12/03/2004 00:30:00 8.3 1 10.3 6.1 8.6 1 11.1 6.1 0.4 0 0.4 0.4 340 6 332 305 100 0 100 0 -7.6 0 -7.3 -7.7 12/03/2004 00:40:00 8.2 1 11.5 6.5 8.5 1 11.1 6.5 0.4 0 0.4 0.4 338 9 332 305 99 0 99 0 -7.6 0 -6.9 -7.7 12/03/2004 00:50:00 8.4 0.8 11.1 6.8 8.7 0.9 10.7 6.8 0.4 0 0.4 0.4 340 9 357 305 99 0 99 0 -7.6 0 -6.9 -7.7 12/03/2004 01:00:00 7.9 0.9 10.7 6.1 8.2 0.9 11.5 6.1 0.4 0 0.4 0.4 343 7 341 305 98 0 98 0 -7.7 0 -7.1 -7.9 12/03/2004 01:10:00 8.3 0.9 10.3 6.1 8.6 1 11.1 6.1 0.4 0 0.4 0.4 341 8 345 305 98 0 97 0 -7.7 0 -7.5 -7.9 12/03/2004 01:20:00 7.7 0.9 10.3 5.7 8 0.9 10.3 5.7 0.4 0 0.4 0.4 341 7 330 305 97 0 97 0 -7.7 0 -7.3 -7.9 12/03/2004 01:30:00 7.3 1.1 10.7 4.9 7.6 1.1 11.1 4.9 0.4 0 0.4 0.4 340 9 333 305 97 0 97 0 -7.9 0 -7.3 -7.9 12/03/2004 01:40:00 7.3 1.2 9.9 4.2 7.6 1.2 9.9 5.3 0.4 0 0.4 0.4 338 9 345 305 96 0 96 0 -7.9 0 -7.3 -8.2 12/03/2004 01:50:00 7.6 0.8 9.1 5.7 7.8 0.8 9.5 5.7 0.4 0 0.4 0.4 341 7 343 305 96 0 96 0 -7.9 0 -7.7 -8.2 12/03/2004 02:00:00 7.6 0.8 9.5 5.7 7.9 0.8 10.3 6.1 0.4 0 0.4 0.4 341 7 327 305 96 0 95 0 -8 0 -7.7 -8.2 12/03/2004 02:10:00 7.8 0.9 9.5 4.9 8.1 0.9 9.9 4.9 0.4 0 0.4 0.4 342 6 334 305 96 0 95 0 -7.9 0 -7.7 -8.2 12/03/2004 02:20:00 8 1 10.7 5.3 8.3 1 11.1 5.3 0.4 0 0.4 0.4 341 6 346 305 95 0 95 0 -8 0 -7.7 -8.2 12/03/2004 02:30:00 7 1.2 10.3 4.6 7.3 1.3 9.9 4.9 0.4 0 0.4 0.4 342 6 344 305 95 0 95 0 -8.1 0 -7.7 -8.2 12/03/2004 02:40:00 7.8 1 9.9 5.3 8.1 1 10.3 5.7 0.4 0 0.4 0.4 342 7 351 305 94 0 94 0 -8 0 -7.7 -8.2 12/03/2004 02:50:00 7.5 1 9.5 5.3 7.8 1 9.9 5.7 0.4 0 0.4 0.4 338 8 338 305 94 0 94 0 -8 0 -7.7 -8.2 12/03/2004 03:00:00 7.5 0.7 9.1 5.7 7.8 0.8 9.5 6.1 0.4 0 0.4 0.4 341 6 344 305 93 0 93 0 -8 0 -7.7 -8.2 12/03/2004 03:10:00 7.3 0.8 9.1 4.9 7.5 0.8 9.9 5.3 0.4 0 0.4 0.4 343 7 336 305 93 0 93 0 -8.2 0 -7.9 -8.2 12/03/2004 03:20:00 7.3 0.9 9.1 5.3 7.6 0.9 9.9 5.7 0.4 0 0.4 0.4 342 7 335 305 93 0 93 0 -8.1 0 -7.7 -8.2 12/03/2004 03:30:00 6.8 0.8 8.8 4.9 7.1 0.8 9.1 4.9 0.4 0 0.4 0.4 340 7 346 305 93 0 93 0 -7.9 0 -7.7 -8.2 12/03/2004 03:40:00 6.7 0.9 9.1 4.9 7 0.9 9.1 4.9 0.4 0 0.4 0.4 341 8 325 305 93 0 93 0 -7.9 0 -7.7 -8.2 12/03/2004 03:50:00 6.5 1.3 9.1 3.8 6.7 1.3 9.1 3.8 0.4 0 0.4 0.4 340 9 340 305 93 0 93 0 -7.9 0 -7.7 -7.9 12/03/2004 04:00:00 7.2 0.8 9.1 5.7 7.5 0.9 9.9 5.7 0.4 0 0.4 0.4 337 8 339 305 92 0 92 0 -7.8 0 -7.3 -7.9 12/03/2004 04:10:00 7 1.1 9.9 4.9 7.3 1.2 9.9 4.6 0.4 0 0.4 0.4 344 14 331 305 92 0 92 0 -7.8 0 -7.3 -7.9 12/03/2004 04:20:00 6.5 1.2 9.1 3.4 6.7 1.2 8.8 4.2 0.4 0 0.4 0.4 346 9 351 305 92 0 92 0 -7.9 0 -7.3 -7.9 12/03/2004 04:30:00 6.5 1.1 9.1 3.8 6.8 1.1 9.1 4.2 0.4 0 0.4 0.4 345 9 345 305 92 0 92 0 -7.9 0 -7.5 -8.2 12/03/2004 04:40:00 7.2 0.9 9.5 5.3 7.5 1 9.9 5.3 0.4 0 0.4 0.4 347 9 329 305 91 0 91 0 -7.9 0 -7.5 -8.2 12/03/2004 04:50:00 7 0.8 8.8 5.3 7.3 0.8 9.5 5.3 0.4 0 0.4 0.4 346 9 340 305 91 0 91 0 -8.2 0 -7.7 -8.4 12/03/2004 05:00:00 6.7 1 9.5 4.9 7.1 1 9.9 4.9 0.4 0 0.4 0.4 349 10 348 305 90 0 91 0 -8.3 0 -8.2 -8.4 12/03/2004 05:10:00 7 0.8 9.9 4.6 7.3 0.9 9.1 5.3 0.4 0 0.4 0.4 345 8 328 305 90 0 90 0 -8.3 0 -7.7 -8.4 12/03/2004 05:20:00 5.7 0.8 8.4 3.8 5.9 0.8 8 4.2 0.4 0 0.4 0.4 348 8 341 305 89 0 90 0 -8.3 0 -8.2 -8.4 12/03/2004 05:30:00 5.9 0.8 8.4 4.2 6.3 0.9 8.8 4.2 0.4 0 0.4 0.4 347 7 357 305 89 0 89 0 -8.3 0 -8.2 -8.4 12/03/2004 05:40:00 5.1 0.7 6.8 3 5.4 0.7 7.2 3.8 0.4 0 0.4 0.4 342 9 333 305 88 0 88 0 -8.3 0 -8.2 -8.4 12/03/2004 05:50:00 5.8 0.7 7.6 3.8 6.1 0.8 8 4.2 0.4 0 0.4 0.4 345 9 347 305 88 0 88 0 -8.2 0 -7.9 -8.4 12/03/2004 06:00:00 5 0.9 7.2 3 5.3 0.8 7.6 3.8 0.4 0 0.4 0.4 339 10 342 305 88 0 88 0 -8.2 0 -7.9 -8.4 12/03/2004 06:10:00 5.4 0.6 6.8 4.2 5.7 0.6 7.2 4.6 0.4 0 0.4 0.4 344 9 351 305 88 0 88 0 -8.2 0 -7.9 -8.4 12/03/2004 06:20:00 4.8 0.8 6.5 3 5.1 0.8 6.8 3.8 0.4 0 0.4 0.4 343 8 351 305 88 0 88 0 -8.2 0 -7.9 -8.2 12/03/2004 06:30:00 5.3 0.9 7.2 2.6 5.6 0.8 7.2 3.8 0.4 0 0.4 0.4 351 10 3 305 88 0 88 0 -8.1 0 -7.9 -8.2 12/03/2004 06:40:00 6.2 0.7 8 4.6 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 348 7 356 305 88 0 88 0 -8 0 -7.7 -8.2 12/03/2004 06:50:00 5.5 0.7 6.8 3.8 5.8 0.7 7.2 3.8 0.4 0 0.4 0.4 337 8 337 305 94 2 87 0 -8.2 0 -7.9 -8.2 12/03/2004 07:00:00 5.5 0.6 7.2 3.8 5.8 0.7 7.6 4.2 0.4 0 0.4 0.4 342 7 331 305 93 0 94 0 -8.2 0 -8.2 -8.4 12/03/2004 07:10:00 4.9 0.7 6.8 3.4 5.2 0.7 6.8 3.8 0.4 0 0.4 0.4 334 6 341 305 93 0 93 0 -8.2 0 -8.2 -8.4 12/03/2004 07:20:00 5.1 0.8 7.2 3.4 5.3 0.8 7.2 3.4 0.4 0 0.4 0.4 326 12 25 305 92 0 92 0 -8.2 0 -8.2 -8.4 12/03/2004 07:30:00 4.9 0.8 6.5 2.6 5.1 0.8 7.2 3 0.4 0 0.4 0.4 336 9 332 305 92 0 92 0 -8.2 0 -7.9 -8.2 12/03/2004 07:40:00 4.4 1 7.2 2.6 4.7 0.9 7.6 3 0.4 0 0.4 0.4 337 16 352 305 93 0 92 0 -8.1 0 -7.9 -8.2 12/03/2004 07:50:00 5.6 0.9 8.4 3.8 5.9 0.9 8.8 3.8 0.4 0 0.4 0.4 331 10 341 305 93 0 93 0 -8 0.1 -7.7 -8.2 12/03/2004 08:00:00 4.7 0.9 6.8 3 5.1 0.8 7.2 3 0.4 0 0.4 0.4 340 6 327 305 92 0 92 0 -8.2 0 -8.2 -8.2 12/03/2004 08:10:00 5.2 0.7 6.8 3.4 5.5 0.7 7.6 3.8 0.4 0 0.4 0.4 338 9 326 305 92 0 92 0 -8.3 0 -8.2 -8.4 12/03/2004 08:20:00 5.1 0.6 6.5 3.4 5.4 0.6 6.8 3.8 0.4 0 0.4 0.4 345 9 330 305 92 0 92 0 -8.3 0 -8.2 -8.4 12/03/2004 08:30:00 4.9 0.9 7.2 2.6 5 0.9 7.6 3 0.4 0 0.4 0.4 330 18 353 305 92 0 92 0 -8.2 0 -7.9 -8.4 12/03/2004 08:40:00 5.1 1 7.6 2.6 5.2 1 8 3 0.4 0 0.4 0.4 315 18 317 305 93 1 94 0 -8.2 0 -7.9 -8.4 12/03/2004 08:50:00 5 1 7.6 3.4 5.3 1 8 3.4 0.4 0 0.4 0.4 335 12 332 305 93 0 93 0 -8.2 0 -7.9 -8.4 12/03/2004 09:00:00 5 0.8 7.2 3 5.3 0.8 7.2 3.4 0.4 0 0.4 0.4 332 6 341 305 93 0 93 0 -8.2 0 -7.9 -8.4 12/03/2004 09:10:00 5 1.2 8 2.3 5 1.1 7.6 2.6 0.4 0 0.4 0.4 308 18 300 305 93 1 93 0 -8.2 0 -7.9 -8.6 12/03/2004 09:20:00 4.6 0.8 6.8 3 4.7 0.8 6.8 3.4 0.4 0 0.4 0.4 311 22 296 305 91 1 91 0 -8.5 0 -8.4 -8.6 12/03/2004 09:30:00 4.3 0.6 6.1 3 4.5 0.5 6.1 3 0.4 0 0.4 0.4 314 13 305 305 91 0 91 0 -8.5 0 -8.4 -8.6 12/03/2004 09:40:00 5.8 0.9 7.6 3.4 5.9 0.9 7.6 3.8 0.4 0 0.4 0.4 314 26 306 305 90 1 92 0 -8.6 0 -8.4 -8.8 12/03/2004 09:50:00 6.2 0.9 8.4 3.8 6.3 0.8 8.4 3.8 0.4 0 0.4 0.4 312 15 307 305 90 0 90 0 -8.5 0 -8.4 -8.8 12/03/2004 10:00:00 5.9 0.7 7.6 4.6 5.9 0.6 7.6 4.6 0.4 0 0.4 0.4 306 18 303 305 89 0 89 0 -8.6 0 -8.2 -8.8 12/03/2004 10:10:00 6.1 0.7 8 4.6 6.2 0.7 8 4.9 0.4 0 0.4 0.4 313 15 315 305 88 0 87 0 -8.6 0.1 -7.9 -9 12/03/2004 10:20:00 6.2 0.9 8.8 4.6 6.3 0.8 8.4 4.6 0.4 0 0.4 0.4 315 13 313 305 87 0 87 0 -8.4 0 -7.9 -8.6 12/03/2004 10:30:00 6.4 0.7 8 4.9 6.5 0.7 8 4.6 0.4 0 0.4 0.4 313 9 279 305 88 0 87 0 -8.5 0 -8.2 -8.6 12/03/2004 10:40:00 5.5 0.8 7.2 3.8 5.6 0.8 7.6 4.2 0.4 0 0.4 0.4 318 9 320 305 88 0 88 0 -8.5 0 -8.4 -8.6 12/03/2004 10:50:00 5.4 0.8 7.6 3.8 5.3 0.8 7.6 3.8 0.4 0 0.4 0.4 309 18 302 305 88 0 88 0 -8.8 0.1 -8.4 -9.2 12/03/2004 11:00:00 5.2 0.6 6.5 3.8 5.1 0.6 6.8 3.8 0.4 0 0.4 0.4 306 13 305 305 87 0 87 0 -9 0 -8.8 -9.2 12/03/2004 11:10:00 5.1 0.8 6.8 3 5.1 0.7 6.8 3.4 0.4 0 0.4 0.4 312 13 303 305 86 0 86 0 -8.9 0 -8.6 -9.2 12/03/2004 11:20:00 5 1 6.8 2.3 5.1 0.9 7.2 3 0.4 0 0.4 0.4 313 16 311 305 85 0 85 0 -8.8 0.1 -8.4 -9.2 12/03/2004 11:30:00 5 0.7 6.8 3.4 5.1 0.6 6.8 3.8 0.4 0 0.4 0.4 314 20 310 305 85 0 85 0 -8.6 0 -8.4 -8.8 12/03/2004 11:40:00 4.6 0.5 6.1 3.4 4.7 0.5 6.1 3.4 0.4 0 0.4 0.4 313 14 309 305 85 0 85 0 -8.6 0 -8.4 -8.8 12/03/2004 11:50:00 4.9 0.6 6.5 3.4 4.9 0.6 6.1 3.4 0.4 0 0.4 0.4 307 16 297 305 84 0 85 0 -8.8 0 -8.6 -9 12/03/2004 12:00:00 5.7 0.8 7.2 3.4 5.6 0.8 7.2 3.4 0.4 0 0.4 0.4 302 19 326 305 84 0 84 0 -8.8 0 -8.8 -9 12/03/2004 12:10:00 5.6 0.8 8 3.8 5.3 0.7 7.6 3.8 0.4 0 0.4 0.4 297 14 2 305 83 0 84 0 -9 0 -8.8 -9.2 12/03/2004 12:20:00 5.9 0.7 8 4.2 5.7 0.8 7.6 3.8 0.4 0 0.4 0.4 299 15 305 305 83 0 84 0 -8.8 0 -8.4 -9 12/03/2004 12:30:00 6.1 0.7 7.6 4.6 5.8 0.6 7.6 4.2 0.4 0 0.4 0.4 297 13 293 305 83 0 83 0 -8.8 0 -8.4 -9 12/03/2004 12:40:00 6.3 0.8 8 4.6 6.1 0.8 8 4.6 0.4 0 0.4 0.4 300 15 288 305 83 0 83 0 -8.8 0 -8.8 -9 12/03/2004 12:50:00 6.7 0.7 8.4 4.9 6.6 0.7 8.4 5.3 0.4 0 0.4 0.4 308 22 301 305 83 0 83 0 -8.7 0 -8.6 -8.8 12/03/2004 13:00:00 6.5 0.6 8 4.9 6.4 0.7 8 4.6 0.4 0 0.4 0.4 302 18 303 305 83 0 82 0 -8.7 0 -8.6 -8.8 12/03/2004 13:10:00 6.4 1 8.4 4.2 6.1 0.9 8.4 4.2 0.4 0 0.4 0.4 297 10 298 305 82 0 83 0 -8.7 0 -8.4 -8.8 12/03/2004 13:20:00 6.7 1 8.8 4.6 6.5 0.9 8.8 4.6 0.4 0 0.4 0.4 307 14 310 305 82 0 82 0 -8.5 0 -8.2 -8.6 12/03/2004 13:30:00 7.3 1 9.5 4.9 7.2 1 9.5 4.9 0.4 0 0.4 0.4 306 17 301 305 82 0 82 0 -8.4 0 -8.2 -8.6 12/03/2004 13:40:00 7.6 0.8 9.5 5.7 7.6 0.9 9.9 5.7 0.4 0 0.4 0.4 310 21 310 305 82 0 82 0 -8.3 0 -8.2 -8.4 12/03/2004 13:50:00 7.5 0.9 9.5 4.9 7.5 0.9 9.5 4.6 0.4 0 0.4 0.4 310 13 295 305 82 0 81 0 -8.3 0 -7.9 -8.4 12/03/2004 14:00:00 7.7 0.8 9.9 5.3 7.6 0.8 9.9 5.7 0.4 0 0.4 0.4 311 26 309 305 81 0 82 0 -8.3 0 -8.2 -8.4 12/03/2004 14:10:00 7.5 0.8 9.9 5.3 7.5 0.8 9.9 5.3 0.4 0 0.4 0.4 316 15 309 305 81 0 82 0 -8.2 0 -7.9 -8.4 12/03/2004 14:20:00 7.3 0.7 9.1 5.7 7.5 0.7 9.1 6.1 0.4 0 0.4 0.4 319 20 326 305 81 0 82 0 -8.2 0 -7.9 -8.4 12/03/2004 14:30:00 7.1 0.6 8.8 5.3 7.3 0.7 9.5 5.7 0.4 0 0.4 0.4 323 11 305 305 81 0 81 0 -8.1 0 -7.7 -8.2 12/03/2004 14:40:00 6.9 0.6 9.1 5.7 7.1 0.7 9.1 5.7 0.4 0 0.4 0.4 323 10 334 305 80 0 80 0 -8.2 0 -7.7 -8.2 12/03/2004 14:50:00 6.7 0.8 8.4 4.6 6.9 0.8 8.8 4.9 0.4 0 0.4 0.4 330 9 329 305 79 0 80 0 -8.1 0 -7.9 -8.2 12/03/2004 15:00:00 6.9 0.8 9.1 5.3 7.2 0.8 9.1 5.7 0.4 0 0.4 0.4 331 6 333 305 79 0 79 0 -8.2 0 -7.9 -8.4 12/03/2004 15:10:00 6.9 0.8 8.8 4.9 7.1 0.8 8.8 5.3 0.4 0 0.4 0.4 335 6 338 305 78 0 78 0 -8.2 0 -7.9 -8.4 12/03/2004 15:20:00 6.6 0.8 8.8 4.9 7 0.9 8.8 4.9 0.4 0 0.4 0.4 345 6 335 305 77 0 77 0 -8.3 0 -8.2 -8.4 12/03/2004 15:30:00 5.7 0.6 7.2 4.6 6.1 0.6 7.6 4.9 0.4 0 0.4 0.4 356 7 348 305 76 0 77 0 -8.3 0 -8.2 -8.4 12/03/2004 15:40:00 6.3 0.9 8.8 4.2 6.6 0.9 9.1 4.9 0.4 0 0.4 0.4 344 6 341 305 75 0 74 0 -8.4 0.1 -8.2 -8.8 12/03/2004 15:50:00 6.3 0.8 8.8 4.2 6.7 0.8 8.8 4.6 0.4 0 0.4 0.4 359 6 3 305 74 0 74 0 -8.6 0 -8.4 -8.8 12/03/2004 16:00:00 5.8 1 7.2 3 6.2 1 8 3.8 0.4 0 0.4 0.4 344 7 345 305 72 0 73 0 -8.7 0 -8.6 -8.8 12/03/2004 16:10:00 5.2 0.8 7.6 3.4 5.6 0.8 8.4 3.8 0.4 0 0.4 0.4 350 11 346 305 71 0 71 0 -8.7 0 -8.6 -8.8 12/03/2004 16:20:00 5.6 0.8 7.6 3.8 5.9 0.8 8 4.2 0.4 0 0.4 0.4 338 8 347 305 71 0 71 0 -8.7 0 -8.6 -9 12/03/2004 16:30:00 5.1 0.9 6.8 3 5.4 0.8 7.6 3.4 0.4 0 0.4 0.4 341 7 347 305 70 0 70 0 -8.7 0 -8.4 -8.8 12/03/2004 16:40:00 5.6 0.9 7.6 3.4 5.9 0.8 8 4.2 0.4 0 0.4 0.4 334 9 335 305 70 0 70 0 -8.6 0 -8.4 -8.8 12/03/2004 16:50:00 5.2 0.8 7.2 3.4 5.5 0.8 7.6 3.8 0.4 0 0.4 0.4 335 10 347 305 70 0 70 0 -8.7 0 -8.4 -8.8 12/03/2004 17:00:00 6 0.7 7.6 4.2 6.3 0.8 8.4 4.2 0.4 0 0.4 0.4 335 6 342 305 70 0 70 0 -8.7 0 -8.4 -8.8 12/03/2004 17:10:00 5.4 0.6 7.2 3.8 5.8 0.6 7.6 4.6 0.4 0 0.4 0.4 333 7 329 305 70 0 69 0 -8.7 0 -8.4 -8.8 12/03/2004 17:20:00 6.1 1.1 8.4 3.8 6.3 1.1 8.8 3.8 0.4 0 0.4 0.4 345 7 346 305 70 0 69 0 -8.6 0 -8.4 -8.8 12/03/2004 17:30:00 6.1 0.8 8 4.6 6.4 0.8 8.4 4.6 0.4 0 0.4 0.4 349 6 339 305 70 0 70 0 -8.6 0 -8.4 -8.8 12/03/2004 17:40:00 6.9 0.7 8.8 5.3 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 340 8 340 305 70 0 69 0 -8.6 0 -8.4 -8.8 12/03/2004 17:50:00 6.3 1.1 8.4 3.4 6.7 1.1 8.8 3.8 0.4 0 0.4 0.4 350 6 347 305 69 0 69 0 -8.7 0 -8.6 -8.8 12/03/2004 18:00:00 6.5 0.9 8.8 4.2 6.9 0.9 9.1 4.6 0.4 0 0.4 0.4 352 7 346 305 69 0 69 0 -8.8 0 -8.8 -9 12/03/2004 18:10:00 6 1 8 3.8 6.4 1 8.4 4.2 0.4 0 0.4 0.4 352 9 3 305 68 0 68 0 -8.9 0 -8.8 -9 12/03/2004 18:20:00 6.6 0.9 8.8 4.2 6.9 0.9 9.1 4.9 0.4 0 0.4 0.4 354 6 0 305 69 0 69 0 -8.9 0 -8.6 -9.2 12/03/2004 18:30:00 6.9 0.8 9.1 4.6 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 357 9 7 305 69 0 69 0 -8.8 0 -8.8 -9 12/03/2004 18:40:00 6.8 0.8 8.8 4.6 7.1 0.8 9.1 5.3 0.4 0 0.4 0.4 3 9 11 305 69 0 69 0 -8.8 0 -8.6 -9 12/03/2004 18:50:00 6.3 1.1 8.8 3.8 6.7 1 9.1 4.6 0.4 0 0.4 0.4 353 6 357 305 69 0 69 0 -8.8 0 -8.6 -9 12/03/2004 19:00:00 6.6 1.2 9.1 4.2 7 1.2 9.1 4.6 0.4 0 0.4 0.4 357 8 3 305 69 0 69 0 -8.7 0 -8.6 -8.8 12/03/2004 19:10:00 7 0.8 9.5 5.3 7.3 0.8 9.5 5.3 0.4 0 0.4 0.4 355 6 347 305 69 0 69 0 -8.6 0 -8.4 -8.8 12/03/2004 19:20:00 7.4 1 9.1 5.3 7.7 1 9.9 5.7 0.4 0 0.4 0.4 351 6 357 305 70 0 70 0 -8.7 0 -8.4 -8.8 12/03/2004 19:30:00 7.9 0.8 9.5 6.1 8.2 0.8 10.3 6.5 0.4 0 0.4 0.4 356 7 353 305 69 0 69 0 -8.8 0 -8.6 -9 12/03/2004 19:40:00 8 1.1 10.3 6.1 8.2 1.1 10.7 6.1 0.4 0 0.4 0.4 359 8 358 305 69 0 69 0 -8.8 0 -8.6 -8.8 12/03/2004 19:50:00 7.9 0.8 9.5 5.7 8.1 1 10.3 6.1 0.4 0 0.4 0.4 4 7 5 305 69 0 69 0 -8.9 0 -8.8 -9 12/03/2004 20:00:00 8 1.1 11.1 5.7 8.3 1.1 11.1 6.1 0.4 0 0.4 0.4 4 9 347 305 69 0 69 0 -8.9 0 -8.8 -9 12/03/2004 20:10:00 8 0.7 10.3 6.1 8.3 0.8 11.1 6.1 0.4 0 0.4 0.4 0 9 358 305 69 0 69 0 -8.9 0 -8.8 -9.2 12/03/2004 20:20:00 7.9 1 10.3 6.1 8.1 1.1 10.7 6.1 0.4 0 0.4 0.4 359 8 356 305 69 0 69 0 -8.7 0 -8.6 -9 12/03/2004 20:30:00 8.5 0.8 10.3 5.7 8.8 0.8 10.7 6.1 0.4 0 0.4 0.4 359 7 356 305 69 0 69 0 -8.7 0 -8.6 -9 12/03/2004 20:40:00 7.7 1.3 10.3 5.3 8 1.3 10.7 5.7 0.4 0 0.4 0.4 6 8 16 305 68 0 67 0 -8.8 0 -8.6 -9 12/03/2004 20:50:00 8.5 1.1 11.1 5.7 8.7 1.1 11.8 5.7 0.4 0 0.4 0.4 11 6 7 305 68 0 69 0 -8.7 0 -8.4 -8.8 12/03/2004 21:00:00 8.6 1 10.7 6.5 8.8 1 11.5 6.8 0.4 0 0.4 0.4 5 7 3 305 68 0 68 0 -8.6 0 -8.4 -8.8 12/03/2004 21:10:00 8.8 1.1 11.8 6.8 9.1 1.2 12.2 6.8 0.4 0 0.4 0.4 3 5 359 305 68 0 68 0 -8.7 0 -8.4 -8.8 12/03/2004 21:20:00 8.1 1 10.7 5.7 8.3 0.9 10.7 6.1 0.4 0 0.4 0.4 11 7 13 305 67 0 67 0 -8.7 0 -8.6 -8.8 12/03/2004 21:30:00 8.2 1 10.7 6.1 8.5 1 11.1 6.1 0.4 0 0.4 0.4 1 4 1 305 67 0 67 0 -8.8 0 -8.6 -9 12/03/2004 21:40:00 8.2 0.9 10.3 6.1 8.5 0.9 10.7 6.5 0.4 0 0.4 0.4 1 6 8 305 67 0 67 0 -8.8 0 -8.6 -9 12/03/2004 21:50:00 8 1.1 11.1 5.3 8.4 1.2 11.5 6.1 0.4 0 0.4 0.4 358 8 350 305 67 0 67 0 -8.8 0 -8.6 -9 12/03/2004 22:00:00 7.5 0.9 9.5 4.6 7.9 1 9.9 4.9 0.4 0 0.4 0.4 358 7 355 305 66 0 67 0 -8.8 0 -8.8 -9 12/03/2004 22:10:00 7.7 1 9.9 5.3 7.9 1.1 9.9 5.7 0.4 0 0.4 0.4 11 12 353 305 66 0 66 0 -8.8 0 -8.6 -9 12/03/2004 22:20:00 7.6 0.8 9.5 5.7 7.9 0.9 10.3 6.1 0.4 0 0.4 0.4 5 8 12 305 66 0 66 0 -8.8 0 -8.6 -9 12/03/2004 22:30:00 8 1 10.7 6.1 8.3 1 11.1 6.1 0.4 0 0.4 0.4 7 6 11 305 66 0 65 0 -8.9 0 -8.8 -9.2 12/03/2004 22:40:00 8.1 0.8 9.9 5.7 8.3 0.8 10.3 5.7 0.4 0 0.4 0.4 16 7 357 305 65 0 66 0 -9 0.1 -8.8 -9.2 12/03/2004 22:50:00 7.8 1.2 11.5 4.6 7.9 1.2 11.5 4.6 0.4 0 0.4 0.4 9 6 9 305 65 0 65 0 -9.1 0 -9 -9.2 12/03/2004 23:00:00 6.5 0.7 8.4 4.6 6.7 0.7 8.8 4.9 0.4 0 0.4 0.4 9 11 22 305 65 0 65 0 -9.3 0 -9 -9.2 12/03/2004 23:10:00 7.1 1.2 9.9 4.6 7.4 1.3 10.3 4.6 0.4 0 0.4 0.4 9 8 2 305 64 0 65 0 -9.3 0 -9.2 -9.2 12/03/2004 23:20:00 7.8 1 10.7 4.9 8 1.1 11.1 5.7 0.4 0 0.4 0.4 13 9 2 305 65 0 65 0 -9.1 0.1 -9 -9.2 12/03/2004 23:30:00 6.9 1.1 9.5 4.6 7.1 1.2 9.9 4.9 0.4 0 0.4 0.4 7 9 12 305 65 0 65 0 -9.2 0 -9 -9.2 12/03/2004 23:40:00 6 1.2 9.1 3.4 6.3 1.2 9.5 3.8 0.4 0 0.4 0.4 11 12 3 305 65 0 65 0 -9.2 0 -9 -9.4 12/03/2004 23:50:00 5.6 1 7.6 3.8 5.8 1 8 3.8 0.4 0 0.4 0.4 25 20 3 305 64 0 65 0 -9.1 0 -8.8 -9.2 12/04/2004 00:00:00 5.9 1.2 9.1 3.4 6.1 1.2 9.5 3.8 0.4 0 0.4 0.4 29 11 30 305 64 0 64 0 -8.9 0 -8.8 -9.2 12/04/2004 00:10:00 6.9 1 9.1 4.9 7 1.1 9.5 4.9 0.4 0 0.4 0.4 36 8 41 305 65 0 65 0 -8.7 0 -8.6 -8.8 12/04/2004 00:20:00 6.8 1.5 9.5 4.2 7 1.5 9.9 4.2 0.4 0 0.4 0.4 27 8 21 305 66 0 66 0 -8.6 0 -8.4 -8.8 12/04/2004 00:30:00 7.2 1 9.9 5.3 7.4 1.1 9.9 4.9 0.4 0 0.4 0.4 39 10 36 305 67 0 67 0 -8.5 0 -8.2 -8.6 12/04/2004 00:40:00 8 1.1 10.3 5.7 8.1 1.2 10.7 5.7 0.4 0 0.4 0.4 28 8 24 305 68 0 69 0 -8.2 0 -7.9 -8.4 12/04/2004 00:50:00 7.3 1.4 10.3 4.9 7.5 1.4 11.1 5.3 0.4 0 0.4 0.4 37 9 19 305 70 0 69 0 -8.1 0 -7.9 -8.2 12/04/2004 01:00:00 6.4 0.6 8 4.9 6.5 0.6 8.4 4.9 0.4 0 0.4 0.4 44 14 65 305 72 1 71 0 -7.9 0 -7.7 -8.2 12/04/2004 01:10:00 7.1 1 10.3 5.3 7.2 1 10.7 5.3 0.4 0 0.4 0.4 51 9 33 305 74 0 74 0 -7.7 0.1 -7.3 -7.9 12/04/2004 01:20:00 7.8 1 10.7 4.9 8 1 11.1 5.3 0.4 0 0.4 0.4 38 8 38 305 75 0 75 0 -7.4 0 -7.3 -7.5 12/04/2004 01:30:00 7.8 0.8 9.9 5.7 7.9 0.9 9.9 5.7 0.4 0 0.4 0.4 47 12 45 305 77 0 77 0 -7.2 0 -7.1 -7.3 12/04/2004 01:40:00 8.1 1 10.3 4.9 8.1 1 10.7 4.9 0.4 0 0.4 0.4 49 9 48 305 78 0 78 0 -7 0 -6.7 -7.3 12/04/2004 01:50:00 8.2 1 11.5 6.1 8.4 1.1 11.8 5.7 0.4 0 0.4 0.4 52 10 48 305 79 0 79 0 -6.9 0 -6.7 -7.1 12/04/2004 02:00:00 7.6 0.7 9.5 5.3 7.8 0.7 9.1 6.1 0.4 0 0.4 0.4 45 8 38 305 80 0 79 0 -6.8 0 -6.7 -6.9 12/04/2004 02:10:00 8.6 1.5 11.8 5.3 8.8 1.5 11.8 5.7 0.4 0 0.4 0.4 43 9 33 305 81 0 81 0 -6.6 0.1 -6.4 -6.9 12/04/2004 02:20:00 8 0.9 10.3 6.1 8.1 0.9 10.7 6.1 0.4 0 0.4 0.4 37 9 42 305 82 0 81 0 -6.5 0 -6.2 -6.7 12/04/2004 02:30:00 7.8 0.7 9.9 5.7 7.6 0.8 9.9 5.7 0.4 0 0.4 0.4 67 9 66 305 83 0 82 0 -6.7 0 -6.4 -6.9 12/04/2004 02:40:00 9.1 0.8 12.2 7.2 9.1 0.8 13.3 7.2 0.4 0 0.4 0.4 57 9 47 305 83 0 83 0 -6.6 0 -6.4 -6.9 12/04/2004 02:50:00 9.2 0.7 11.1 6.8 9.2 0.8 11.1 6.5 0.4 0 0.4 0.4 50 8 39 305 83 0 83 0 -6.6 0 -6.4 -6.9 12/04/2004 03:00:00 10 0.8 11.5 8 10.1 0.8 12.2 7.2 0.4 0 0.4 0.4 57 6 56 305 83 0 83 0 -6.6 0 -6.4 -6.9 12/04/2004 03:10:00 9.3 1.1 11.8 7.2 9.4 1.1 11.8 6.8 0.4 0 0.4 0.4 53 7 60 305 83 0 82 0 -6.8 0 -6.7 -6.9 12/04/2004 03:20:00 9.9 1.1 12.2 7.6 10 1.1 12.6 7.2 0.4 0 0.4 0.4 53 6 60 305 82 0 82 0 -6.5 0 -6.4 -6.9 12/04/2004 03:30:00 9.2 0.8 11.8 6.8 9.1 0.9 11.5 6.5 0.4 0 0.4 0.4 66 8 71 305 82 0 82 0 -6.5 0 -6.4 -6.7 12/04/2004 03:40:00 8 0.8 10.3 6.1 7.8 0.9 10.7 6.1 0.4 0 0.4 0.4 69 6 56 305 81 0 81 0 -6.7 0 -6.7 -6.9 12/04/2004 03:50:00 9.8 1 11.8 6.1 9.9 1 12.2 6.5 0.4 0 0.4 0.4 58 7 69 305 81 0 81 0 -6.5 0 -6.2 -6.7 12/04/2004 04:00:00 9.3 1.1 11.8 6.1 9.4 1 11.5 6.5 0.4 0 0.4 0.4 56 9 70 305 80 0 80 0 -6.5 0 -6.4 -6.7 12/04/2004 04:10:00 10.2 0.8 11.8 7.6 10.3 0.9 12.6 8 0.4 0 0.4 0.4 55 8 69 305 79 0 80 0 -6.6 0 -6.4 -6.7 12/04/2004 04:20:00 9.8 1 12.6 7.6 9.8 1 12.6 7.6 0.4 0 0.4 0.4 58 10 57 305 78 0 78 0 -6.6 0 -6.7 -6.7 12/04/2004 04:30:00 9.5 1.1 11.8 6.5 9.4 1.2 11.8 6.1 0.4 0 0.4 0.4 70 6 80 305 77 0 78 0 -6.6 0 -6.4 -6.9 12/04/2004 04:40:00 9.5 0.8 11.5 7.2 9.3 0.9 11.8 7.2 0.4 0 0.4 0.4 74 6 85 305 76 0 76 0 -6.6 0 -6.7 -6.7 12/04/2004 04:50:00 9.6 1 13.7 6.8 9.4 1.1 12.2 6.5 0.4 0 0.4 0.4 67 7 65 305 76 0 76 0 -6.5 0 -6.4 -6.7 12/04/2004 05:00:00 11 1.2 13.7 8 11 1.3 13.3 6.8 0.4 0 0.4 0.4 60 8 57 305 76 0 76 0 -6.5 0 -6.2 -6.7 12/04/2004 05:10:00 11.1 0.9 13 8.4 11.1 1 13.3 8.4 0.4 0 0.4 0.4 63 8 60 305 76 0 76 0 -6.5 0 -6.4 -6.7 12/04/2004 05:20:00 10.8 1 13.3 8.8 10.7 1.1 13.3 8 0.4 0 0.4 0.4 64 7 78 305 76 0 76 0 -6.4 0 -6.2 -6.7 12/04/2004 05:30:00 10.6 0.7 12.6 8.4 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 54 5 52 305 75 0 76 0 -6.4 0 -6.2 -6.7 12/04/2004 05:40:00 11.4 1.1 15.6 9.1 11.5 1.1 15.3 9.1 0.4 0 0.4 0.4 56 7 58 305 75 0 75 0 -6.4 0 -6.2 -6.7 12/04/2004 05:50:00 12.1 0.9 14.5 9.5 12.1 1 14.5 9.1 0.4 0 0.4 0.4 56 6 57 305 75 0 75 0 -6.2 0 -6 -6.4 12/04/2004 06:00:00 11.9 0.7 13.7 9.9 11.9 0.7 13.7 9.5 0.4 0 0.4 0.4 61 6 57 305 74 0 74 0 -6.3 0.1 -6.2 -6.7 12/04/2004 06:10:00 12.6 1 15.6 9.9 12.7 1 15.3 9.5 0.4 0 0.4 0.4 63 5 62 305 75 0 75 0 -6.4 0.1 -6.2 -6.7 12/04/2004 06:20:00 12.8 1.3 16.1 9.5 12.8 1.4 16.1 9.5 0.4 0 0.4 0.4 60 7 52 305 76 0 77 0 -6.4 0.1 -6.2 -6.7 12/04/2004 06:30:00 13.7 1 16.8 10.3 13.6 1.1 16.4 10.3 0.4 0 0.4 0.4 58 6 58 305 80 1 82 0 -6.4 0 -6.2 -6.7 12/04/2004 06:40:00 13.6 0.8 15.6 11.5 13.7 0.8 15.6 11.5 0.4 0 0.4 0.4 62 3 62 305 83 0 82 0 -6.4 0 -6.2 -6.7 12/04/2004 06:50:00 13.6 1 16.1 10.3 13.5 1.1 16.1 10.3 0.4 0 0.4 0.4 57 6 57 305 85 0 84 0 -6.3 0 -6 -6.7 12/04/2004 07:00:00 12.9 0.7 14.5 11.1 12.8 0.7 14.5 10.7 0.4 0 0.4 0.4 58 5 49 305 86 0 85 0 -6.3 0 -6.2 -6.7 12/04/2004 07:10:00 12.1 1.3 16.1 9.5 11.9 1.4 16.1 9.1 0.4 0 0.4 0.4 62 7 60 305 87 0 87 0 -6.2 0 -6 -6.4 12/04/2004 07:20:00 13.1 1 16.1 10.7 13.1 1 15.6 10.3 0.4 0 0.4 0.4 54 5 57 305 87 0 87 0 -6.2 0 -6 -6.4 12/04/2004 07:30:00 12.9 1.5 16.4 9.1 12.9 1.6 16.4 9.1 0.4 0 0.4 0.4 56 6 57 305 86 0 86 0 -6.1 0 -6 -6.2 12/04/2004 07:40:00 14.3 1.1 16.8 11.1 14.3 1.2 17.2 10.7 0.4 0 0.4 0.4 49 5 44 305 86 0 87 0 -6.1 0 -5.8 -6.2 12/04/2004 07:50:00 14.1 1.1 16.8 11.5 14 1.1 16.8 11.1 0.4 0 0.4 0.4 51 7 57 305 87 0 86 0 -5.9 0 -5.8 -6.2 12/04/2004 08:00:00 14.7 1.1 17.6 11.8 14.6 1.2 17.9 11.8 0.4 0 0.4 0.4 50 5 61 305 87 0 87 0 -5.9 0 -5.8 -6 12/04/2004 08:10:00 14.6 1.1 17.2 11.5 14.5 1.1 17.2 11.5 0.4 0 0.4 0.4 52 5 52 305 87 0 87 0 -5.9 0 -5.8 -6 12/04/2004 08:20:00 14.2 1.1 16.8 11.5 14 1.2 17.2 11.5 0.4 0 0.4 0.4 53 6 54 305 88 0 88 0 -6 0 -5.8 -6.2 12/04/2004 08:30:00 14.7 1.4 18.7 11.8 14.7 1.4 19.5 11.8 0.4 0 0.4 0.4 56 6 52 305 88 0 88 0 -5.9 0 -5.8 -6 12/04/2004 08:40:00 14.9 1.1 17.2 11.8 14.8 1.1 17.6 12.2 0.4 0 0.4 0.4 54 4 56 305 88 0 88 0 -5.9 0 -5.8 -6.2 12/04/2004 08:50:00 14.9 1.3 17.9 11.5 14.9 1.3 18.7 11.1 0.4 0 0.4 0.4 55 5 56 305 88 0 88 0 -5.9 0 -5.8 -6 12/04/2004 09:00:00 14.7 1.2 17.9 11.8 14.5 1.2 17.6 10.3 0.4 0 0.4 0.4 54 6 51 305 88 0 88 0 -5.7 0.1 -5.6 -6 12/04/2004 09:10:00 14.9 1.1 17.2 10.7 14.8 1.1 17.2 10.7 0.4 0 0.4 0.4 51 6 48 305 88 0 88 0 -5.8 0 -5.6 -6 12/04/2004 09:20:00 15.3 1.1 17.6 12.2 15.1 1.2 17.6 11.5 0.4 0 0.4 0.4 56 5 48 305 88 0 88 0 -5.7 0 -5.6 -6 12/04/2004 09:30:00 14.9 1 17.2 12.6 14.7 1 17.2 11.8 0.4 0 0.4 0.4 55 5 59 305 88 0 88 0 -5.7 0 -5.6 -6 12/04/2004 09:40:00 16.3 1.2 19.1 12.2 16.1 1.3 19.1 11.8 0.4 0 0.4 0.4 55 4 52 305 88 0 88 0 -5.7 0 -5.3 -5.8 12/04/2004 09:50:00 15.2 1.3 18.3 12.2 15.1 1.4 18.3 11.8 0.4 0 0.4 0.4 54 6 62 305 89 0 88 0 -5.6 0.1 -5.6 -6 12/04/2004 10:00:00 15.5 1.1 17.9 11.8 15.3 1.2 18.3 11.8 0.4 0 0.4 0.4 60 6 68 305 90 0 90 0 -5.7 0 -5.6 -5.8 12/04/2004 10:10:00 15.2 1 17.6 12.2 15.1 1.1 17.6 11.8 0.4 0 0.4 0.4 62 5 61 305 90 0 90 0 -5.8 0 -5.6 -6 12/04/2004 10:20:00 15.4 1 17.6 12.6 15.1 1.1 17.6 11.8 0.4 0 0.4 0.4 69 5 78 305 89 0 89 0 -6 0 -5.6 -6.2 12/04/2004 10:30:00 15.1 1 17.6 12.2 14.9 1 17.6 12.2 0.4 0 0.4 0.4 70 5 61 305 88 0 88 0 -6.1 0 -5.8 -6.2 12/04/2004 10:40:00 15.6 1.3 18.3 12.6 15.5 1.4 17.9 12.2 0.4 0 0.4 0.4 65 5 61 305 89 0 89 0 -6.1 0 -5.8 -6.2 12/04/2004 10:50:00 15.6 1.3 18.7 12.6 15.4 1.4 18.7 11.5 0.4 0 0.4 0.4 66 5 69 305 90 0 90 0 -6.2 0 -5.8 -6.4 12/04/2004 11:00:00 15.7 1.2 18.7 12.2 15.6 1.2 18.3 11.8 0.4 0 0.4 0.4 55 4 56 305 91 0 91 0 -6 0 -5.8 -6.2 12/04/2004 11:10:00 15.1 1 17.6 12.6 14.9 1 17.6 11.8 0.4 0 0.4 0.4 59 7 61 305 92 0 91 0 -5.9 0 -5.6 -6.2 12/04/2004 11:20:00 15.8 1.6 19.9 11.8 15.6 1.7 20.2 11.8 0.4 0 0.4 0.4 58 5 48 305 92 0 92 0 -5.9 0 -5.8 -6.2 12/04/2004 11:30:00 15.5 1.6 19.9 11.8 15.3 1.7 19.5 11.5 0.4 0 0.4 0.4 56 5 55 305 93 1 94 0 -5.9 0 -5.8 -6.2 12/04/2004 11:40:00 16.8 1.2 19.5 13.3 16.7 1.3 19.5 12.6 0.4 0 0.4 0.4 68 8 66 305 94 0 94 0 -6.1 0.1 -5.8 -6.4 12/04/2004 11:50:00 17.3 0.9 20.6 14.1 17.1 1 19.5 14.5 0.4 0 0.4 0.4 66 4 60 305 94 0 94 0 -6.1 0 -6 -6.2 12/04/2004 12:00:00 16.6 1 19.1 13.7 16.3 1.1 18.7 13 0.4 0 0.4 0.4 65 4 61 305 94 0 94 0 -6 0 -5.8 -6.2 12/04/2004 12:10:00 16.4 1.1 18.7 13.3 16.2 1.2 19.1 13 0.4 0 0.4 0.4 59 7 62 305 94 0 94 0 -5.9 0 -5.8 -6 12/04/2004 12:20:00 16.7 1.1 19.9 14.1 16.5 1.2 19.9 13 0.4 0 0.4 0.4 56 5 54 305 94 0 94 0 -5.9 0 -5.8 -6 12/04/2004 12:30:00 17 1.3 20.2 13.3 16.8 1.4 19.9 13 0.4 0 0.4 0.4 59 6 59 305 94 0 94 0 -6 0 -5.8 -6.2 12/04/2004 12:40:00 17.1 1.3 20.2 13.7 16.9 1.3 20.2 13.3 0.4 0 0.4 0.4 54 4 43 305 94 0 94 0 -6 0 -5.8 -6.2 12/04/2004 12:50:00 16.6 1.2 19.1 13.7 16.4 1.3 19.5 13 0.4 0 0.4 0.4 54 5 55 305 94 0 94 0 -5.9 0.1 -5.6 -6.2 12/04/2004 13:00:00 16.5 1 18.7 13.3 16.3 1.2 19.1 13 0.4 0 0.4 0.4 57 8 47 305 94 0 94 0 -5.9 0 -5.8 -6.2 12/04/2004 13:10:00 15.3 1.1 19.1 12.2 15.1 1.2 18.7 12.6 0.4 0 0.4 0.4 63 7 60 305 94 0 94 0 -6.1 0.1 -5.8 -6.4 12/04/2004 13:20:00 15.5 1.4 19.1 12.2 15.3 1.5 19.1 11.8 0.4 0 0.4 0.4 58 6 60 305 94 0 94 0 -5.9 0 -5.6 -6.2 12/04/2004 13:30:00 15.4 1.3 19.5 12.2 15.3 1.2 18.7 11.8 0.4 0 0.4 0.4 60 5 50 305 94 0 94 0 -5.9 0 -5.8 -6 12/04/2004 13:40:00 15.5 0.9 17.2 13 15.4 1 17.6 12.6 0.4 0 0.4 0.4 54 5 58 305 93 0 93 0 -5.9 0 -5.8 -6 12/04/2004 13:50:00 14.8 1.2 17.2 11.1 14.7 1.2 17.2 10.7 0.4 0 0.4 0.4 63 6 65 305 93 0 93 0 -6.1 0 -5.8 -6.2 12/04/2004 14:00:00 13.4 1.1 16.1 10.3 13.3 1.1 16.1 10.3 0.4 0 0.4 0.4 61 5 57 305 93 0 93 0 -5.9 0 -5.8 -6 12/04/2004 14:10:00 13.4 1 16.4 11.1 13.2 1.1 15.6 10.3 0.4 0 0.4 0.4 58 5 56 305 92 0 92 0 -5.9 0 -5.8 -6 12/04/2004 14:20:00 13.9 1 16.1 11.5 13.8 1 16.4 11.1 0.4 0 0.4 0.4 56 6 52 305 92 0 92 0 -5.9 0 -5.8 -6 12/04/2004 14:30:00 13.4 1.1 15.6 10.7 13.2 1.2 16.1 9.5 0.4 0 0.4 0.4 51 6 61 305 92 0 92 0 -5.8 0 -5.6 -6 12/04/2004 14:40:00 13.6 0.9 15.6 10.3 13.5 1 15.6 10.3 0.4 0 0.4 0.4 49 5 56 305 93 0 92 0 -5.7 0 -5.6 -5.8 12/04/2004 14:50:00 13.3 0.9 15.3 11.1 13.3 1 14.9 10.7 0.4 0 0.4 0.4 47 4 45 305 93 0 92 0 -5.6 0 -5.6 -5.8 12/04/2004 15:00:00 12.8 0.9 15.3 10.3 12.7 1 15.3 10.3 0.4 0 0.4 0.4 41 5 49 305 93 0 93 0 -5.6 0 -5.6 -5.8 12/04/2004 15:10:00 13 0.9 14.9 9.5 13 0.9 15.3 9.9 0.4 0 0.4 0.4 43 5 48 305 93 0 93 0 -5.6 0 -5.3 -5.8 12/04/2004 15:20:00 12.9 0.8 14.5 10.7 12.9 0.9 14.9 9.9 0.4 0 0.4 0.4 42 5 46 305 93 0 93 0 -5.5 0 -5.3 -5.6 12/04/2004 15:30:00 12.6 0.8 14.1 10.3 12.5 0.8 14.1 10.3 0.4 0 0.4 0.4 43 5 47 305 93 0 93 0 -5.3 0.1 -5.1 -5.6 12/04/2004 15:40:00 12.4 0.8 14.1 9.9 12.4 0.8 14.1 9.5 0.4 0 0.4 0.4 41 6 30 305 94 0 94 0 -5.2 0.1 -4.9 -5.6 12/04/2004 15:50:00 11.8 0.8 13.7 9.9 11.7 0.9 13.7 9.5 0.4 0 0.4 0.4 50 7 42 305 94 0 94 0 -4.9 0 -4.7 -5.1 12/04/2004 16:00:00 12.1 0.8 14.1 9.5 12 0.9 14.1 9.5 0.4 0 0.4 0.4 49 6 41 305 95 0 95 0 -4.7 0 -4.5 -4.9 12/04/2004 16:10:00 13.3 1 15.6 10.7 13.3 1 16.1 10.7 0.4 0 0.4 0.4 44 5 50 305 95 0 95 0 -4.8 0 -4.5 -4.9 12/04/2004 16:20:00 13.1 0.9 15.3 10.7 13 1 15.3 10.3 0.4 0 0.4 0.4 44 6 40 305 95 0 95 0 -4.7 0 -4.5 -4.7 12/04/2004 16:30:00 13.2 1.1 16.1 10.7 13.1 1.2 15.6 9.9 0.4 0 0.4 0.4 46 5 44 305 95 0 95 0 -4.5 0 -4.2 -4.7 12/04/2004 16:40:00 14.4 0.9 17.2 11.8 14.3 1 17.6 11.5 0.4 0 0.4 0.4 50 4 44 305 95 0 95 0 -4.4 0 -4 -4.7 12/04/2004 16:50:00 14.3 1 16.8 11.5 14.2 1.1 16.8 10.7 0.4 0 0.4 0.4 53 5 58 305 94 0 95 0 -4.2 0 -4 -4.5 12/04/2004 17:00:00 14.5 1.1 18.3 11.5 14.4 1.2 17.6 11.5 0.4 0 0.4 0.4 50 5 57 305 94 0 94 0 -4.3 0 -4 -4.5 12/04/2004 17:10:00 15.8 1 18.3 12.6 15.7 1.1 18.3 12.6 0.4 0 0.4 0.4 50 4 51 305 94 0 94 0 -4.3 0 -4 -4.5 12/04/2004 17:20:00 17.1 1 19.1 14.1 16.9 1 19.1 13.3 0.4 0 0.4 0.4 48 4 46 305 95 0 95 0 -4.2 0 -4 -4.5 12/04/2004 17:30:00 17.4 0.9 19.5 14.5 17.2 1 19.5 13.7 0.4 0 0.4 0.4 49 4 49 305 95 0 95 0 -4 0 -3.8 -4.2 12/04/2004 17:40:00 16.7 1.1 19.1 13.7 16.5 1.2 19.1 13 0.4 0 0.4 0.4 49 4 48 305 95 0 95 0 -3.9 0 -3.8 -4.2 12/04/2004 17:50:00 15.9 1.1 18.3 12.6 15.7 1.2 18.3 12.2 0.4 0 0.4 0.4 51 4 58 305 96 0 96 0 -3.9 0 -3.6 -4 12/04/2004 18:00:00 15.7 1.2 19.5 13 15.4 1.3 18.7 12.2 0.4 0 0.4 0.4 53 7 47 305 97 1 97 0 -3.7 0 -3.3 -4 12/04/2004 18:10:00 15.1 1.3 19.5 11.8 14.8 1.4 19.1 11.8 0.4 0 0.4 0.4 72 5 74 305 98 0 98 0 -3.8 0 -3.3 -4 12/04/2004 18:20:00 15.7 1.1 18.3 12.6 15.5 1.1 19.1 13 0.4 0 0.4 0.4 70 3 69 305 98 0 98 0 -3.8 0 -3.6 -3.8 12/04/2004 18:30:00 16.1 1.2 18.3 12.2 15.7 1.3 18.7 12.2 0.4 0 0.4 0.4 66 4 67 305 97 0 97 0 -3.7 0 -3.6 -3.8 12/04/2004 18:40:00 16.3 1 18.7 13.7 16.1 1.1 18.3 13 0.4 0 0.4 0.4 68 4 62 305 96 0 96 0 -3.6 0 -3.3 -3.8 12/04/2004 18:50:00 16 0.8 17.9 13.7 15.8 0.8 17.6 13.7 0.4 0 0.4 0.4 65 4 67 305 95 0 95 0 -3.6 0 -3.3 -3.8 12/04/2004 19:00:00 15.5 1.4 18.3 11.8 15.2 1.5 18.7 11.5 0.4 0 0.4 0.4 66 6 62 305 95 0 95 0 -3.6 0 -3.3 -3.8 12/04/2004 19:10:00 14.7 1.3 17.6 11.5 14.4 1.4 17.6 11.1 0.4 0 0.4 0.4 72 7 73 305 94 0 94 0 -3.6 0 -3.3 -3.8 12/04/2004 19:20:00 14.9 1.2 17.9 11.1 14.6 1.2 17.6 10.7 0.4 0 0.4 0.4 67 6 66 305 94 0 94 0 -3.6 0 -3.3 -3.8 12/04/2004 19:30:00 15.7 1 18.3 13.3 15.4 1.1 17.9 12.2 0.4 0 0.4 0.4 67 5 62 305 94 0 94 0 -3.6 0.1 -3.3 -3.8 12/04/2004 19:40:00 15.6 1 17.9 12.2 15.3 1 17.9 13 0.4 0 0.4 0.4 65 4 66 305 93 0 93 0 -3.6 0 -3.3 -3.8 12/04/2004 19:50:00 15.4 1.2 17.9 12.2 15.2 1.3 17.9 11.1 0.4 0 0.4 0.4 67 5 62 305 93 0 92 0 -3.7 0 -3.3 -3.8 12/04/2004 20:00:00 16 0.9 18.3 13.3 15.7 1 18.3 12.2 0.4 0 0.4 0.4 67 3 71 305 92 0 92 0 -3.7 0 -3.6 -3.8 12/04/2004 20:10:00 15.5 1.1 17.9 13 15.3 1.1 18.3 11.8 0.4 0 0.4 0.4 69 4 67 305 91 0 91 0 -3.8 0 -3.6 -3.8 12/04/2004 20:20:00 16.3 0.9 18.3 13 16.1 1 18.3 12.6 0.4 0 0.4 0.4 66 4 65 305 90 0 90 0 -3.7 0 -3.6 -3.8 12/04/2004 20:30:00 16.1 1 18.3 13 15.8 1.1 17.9 13 0.4 0 0.4 0.4 67 6 62 305 90 0 90 0 -3.6 0 -3.3 -3.8 12/04/2004 20:40:00 16.1 1.1 19.5 13 15.8 1.1 18.7 12.6 0.4 0 0.4 0.4 66 5 60 305 89 0 90 0 -3.6 0 -3.1 -3.8 12/04/2004 20:50:00 15.7 1.2 19.1 13 15.4 1.2 18.7 12.6 0.4 0 0.4 0.4 67 5 64 305 89 0 90 0 -3.6 0 -3.1 -3.8 12/04/2004 21:00:00 16.1 1.2 18.7 12.2 15.9 1.3 18.7 12.2 0.4 0 0.4 0.4 69 4 72 305 89 0 89 0 -3.7 0 -3.6 -3.8 12/04/2004 21:10:00 15.9 1 18.3 12.6 15.7 1.1 18.7 12.6 0.4 0 0.4 0.4 68 3 66 305 88 0 88 0 -3.6 0 -3.3 -3.8 12/04/2004 21:20:00 15.7 1.1 18.3 12.6 15.5 1.1 17.6 12.2 0.4 0 0.4 0.4 65 4 65 305 88 0 88 0 -3.6 0 -3.3 -3.8 12/04/2004 21:30:00 16.1 1.3 19.1 12.6 15.9 1.5 19.1 11.1 0.4 0 0.4 0.4 65 4 64 305 88 0 88 0 -3.6 0 -3.3 -3.8 12/04/2004 21:40:00 15.4 1 17.9 13 15.2 1.1 17.9 12.2 0.4 0 0.4 0.4 69 5 67 305 87 0 88 0 -3.6 0.1 -3.3 -3.8 12/04/2004 21:50:00 15.3 1.3 18.3 11.8 15 1.3 17.9 11.5 0.4 0 0.4 0.4 65 5 69 305 87 0 87 0 -3.6 0 -3.3 -3.8 12/04/2004 22:00:00 14.9 1.1 17.9 12.2 14.7 1.2 17.6 11.5 0.4 0 0.4 0.4 71 6 71 305 87 0 87 0 -3.7 0 -3.6 -3.8 12/04/2004 22:10:00 14.8 1.2 17.9 10.7 14.5 1.3 17.6 10.3 0.4 0 0.4 0.4 71 6 69 305 86 0 86 0 -3.9 0 -3.6 -4 12/04/2004 22:20:00 14.9 1.3 17.9 11.1 14.6 1.5 17.9 10.3 0.4 0 0.4 0.4 76 7 67 305 86 0 86 0 -3.9 0 -3.8 -4 12/04/2004 22:30:00 14.7 1.2 18.3 11.5 14.4 1.2 17.6 10.7 0.4 0 0.4 0.4 72 5 71 305 87 0 87 0 -4.1 0 -4 -4.2 12/04/2004 22:40:00 15.1 1.2 17.9 11.5 14.8 1.4 18.3 10.7 0.4 0 0.4 0.4 71 5 73 305 87 0 87 0 -4.1 0 -4 -4.2 12/04/2004 22:50:00 15.8 1.2 18.7 12.2 15.6 1.3 18.7 12.6 0.4 0 0.4 0.4 68 4 67 305 88 0 88 0 -4.2 0 -4 -4.5 12/04/2004 23:00:00 15.6 1.2 18.3 12.6 15.4 1.3 18.3 11.8 0.4 0 0.4 0.4 69 6 68 305 88 0 88 0 -4.2 0 -4 -4.5 12/04/2004 23:10:00 15.1 1.4 18.3 11.1 14.9 1.6 18.3 10.7 0.4 0 0.4 0.4 71 5 69 305 89 0 89 0 -4.2 0 -4 -4.5 12/04/2004 23:20:00 15.4 1.3 18.3 11.8 15.2 1.4 18.3 11.8 0.4 0 0.4 0.4 69 5 71 305 89 0 90 0 -4.2 0 -4 -4.2 12/04/2004 23:30:00 16.4 1 19.1 13 16.2 1.1 18.7 12.2 0.4 0 0.4 0.4 72 4 71 305 90 0 90 0 -4.4 0 -4 -4.5 12/04/2004 23:40:00 15.8 1.3 19.1 12.2 15.6 1.4 19.1 11.8 0.4 0 0.4 0.4 71 4 72 305 91 0 91 0 -4.4 0 -4.2 -4.7 12/04/2004 23:50:00 15.2 1.5 18.7 11.8 15 1.5 18.3 10.7 0.4 0 0.4 0.4 68 5 72 305 91 0 91 0 -4.5 0 -4.2 -4.7 12/05/2004 00:00:00 15.8 1.5 19.1 11.8 15.7 1.5 19.1 11.8 0.4 0 0.4 0.4 64 5 59 305 91 0 91 0 -4.4 0 -4 -4.7 12/05/2004 00:10:00 16.1 1.4 19.5 11.5 15.8 1.6 19.5 11.1 0.4 0 0.4 0.4 64 5 62 305 92 0 92 0 -4.4 0 -4.2 -4.7 12/05/2004 00:20:00 15.2 1.3 17.9 11.8 15 1.5 18.3 11.5 0.4 0 0.4 0.4 63 6 65 305 93 0 93 0 -4.5 0 -4.5 -4.7 12/05/2004 00:30:00 16.1 1 18.3 13.3 15.7 1.2 18.3 12.2 0.4 0 0.4 0.4 63 4 67 305 94 1 95 0 -4.5 0 -4.5 -4.7 12/05/2004 00:40:00 16.6 1 20.2 13.7 16.3 1.1 19.9 13.7 0.4 0 0.4 0.4 65 6 71 305 95 0 95 0 -4.5 0 -4.5 -4.7 12/05/2004 00:50:00 15.7 1.5 19.1 11.8 15.6 1.6 19.1 10.7 0.4 0 0.4 0.4 74 5 80 305 95 0 95 0 -4.9 0 -4.7 -4.9 12/05/2004 01:00:00 16.4 1.3 19.5 13.3 16.1 1.3 19.5 13 0.4 0 0.4 0.4 68 5 63 305 94 0 94 0 -4.7 0 -4.5 -4.7 12/05/2004 01:10:00 16 1.4 19.5 12.2 15.7 1.5 18.7 11.8 0.4 0 0.4 0.4 66 5 62 305 94 0 94 0 -4.6 0 -4.5 -4.7 12/05/2004 01:20:00 15.6 1.4 18.7 12.2 15.4 1.3 18.7 12.2 0.4 0 0.4 0.4 67 5 66 305 93 0 94 0 -4.6 0 -4.5 -4.7 12/05/2004 01:30:00 14.9 1.5 18.3 11.5 14.6 1.5 18.3 10.7 0.4 0 0.4 0.4 66 7 62 305 93 0 93 0 -4.6 0 -4.5 -4.7 12/05/2004 01:40:00 15.1 1.2 18.3 12.6 14.8 1.3 17.9 11.5 0.4 0 0.4 0.4 71 5 69 305 92 0 92 0 -4.7 0 -4.5 -4.9 12/05/2004 01:50:00 13.7 1 16.8 10.7 13.4 1.1 16.1 10.3 0.4 0 0.4 0.4 69 8 81 305 91 0 91 0 -4.7 0 -4.5 -4.9 12/05/2004 02:00:00 14.7 1.1 17.6 11.5 14.4 1.2 17.2 11.5 0.4 0 0.4 0.4 65 5 64 305 91 0 91 0 -4.6 0 -4.5 -4.7 12/05/2004 02:10:00 14.1 1 17.2 11.1 13.8 1.2 17.9 10.7 0.4 0 0.4 0.4 72 6 64 305 90 0 90 0 -4.7 0 -4.5 -4.9 12/05/2004 02:20:00 15.1 1.3 18.3 10.7 14.8 1.5 18.3 10.3 0.4 0 0.4 0.4 67 6 71 305 89 0 89 0 -4.6 0 -4.5 -4.7 12/05/2004 02:30:00 15.2 1.2 18.3 12.6 15 1.2 18.3 12.6 0.4 0 0.4 0.4 63 7 58 305 89 0 89 0 -4.6 0 -4.5 -4.7 12/05/2004 02:40:00 15.2 1.5 19.1 11.8 14.9 1.5 19.1 11.1 0.4 0 0.4 0.4 62 6 67 305 88 0 89 0 -4.6 0.1 -4.2 -4.9 12/05/2004 02:50:00 15.6 1.1 18.3 13 15.4 1.1 18.3 12.2 0.4 0 0.4 0.4 67 5 70 305 88 0 88 0 -4.7 0 -4.5 -4.9 12/05/2004 03:00:00 15.5 1.1 18.7 13 15.2 1.2 18.3 12.2 0.4 0 0.4 0.4 66 5 71 305 87 0 88 0 -4.6 0.1 -4.2 -4.9 12/05/2004 03:10:00 15.5 1.1 18.3 12.2 15.2 1.1 17.9 11.1 0.4 0 0.4 0.4 67 5 64 305 87 0 87 0 -4.6 0 -4.2 -4.7 12/05/2004 03:20:00 15.2 1.2 18.7 11.8 14.9 1.3 17.9 11.5 0.4 0 0.4 0.4 72 5 69 305 87 0 87 0 -4.7 0 -4.2 -4.9 12/05/2004 03:30:00 15.9 1 18.3 13.3 15.7 1 17.9 12.2 0.4 0 0.4 0.4 68 5 69 305 86 0 86 0 -4.8 0.1 -4.2 -4.9 12/05/2004 03:40:00 15.4 1.2 17.6 11.8 15.1 1.2 17.6 11.5 0.4 0 0.4 0.4 65 5 65 305 85 0 85 0 -4.7 0 -4 -4.9 12/05/2004 03:50:00 15.5 1.2 18.7 12.6 15.2 1.3 18.7 12.2 0.4 0 0.4 0.4 65 3 65 305 85 0 85 0 -4.6 0 -4.2 -4.7 12/05/2004 04:00:00 15.9 1.1 18.7 12.6 15.7 1.2 18.3 12.2 0.4 0 0.4 0.4 62 5 61 305 86 0 86 0 -4.5 0 -4.2 -4.7 12/05/2004 04:10:00 15.5 1.4 18.7 11.8 15.2 1.5 19.5 11.8 0.4 0 0.4 0.4 63 5 70 305 87 0 87 0 -4.4 0 -4.2 -4.5 12/05/2004 04:20:00 15.7 1.3 19.5 12.2 15.4 1.3 19.1 11.5 0.4 0 0.4 0.4 63 6 59 305 88 0 88 0 -4.4 0 -4.2 -4.5 12/05/2004 04:30:00 15.4 1 17.9 11.8 15.1 1.1 17.6 12.2 0.4 0 0.4 0.4 63 6 69 305 88 0 88 0 -4.4 0 -4.2 -4.5 12/05/2004 04:40:00 14.4 1.5 17.6 11.1 14.2 1.5 17.2 10.7 0.4 0 0.4 0.4 66 6 67 305 88 0 88 0 -4.4 0 -4.2 -4.5 12/05/2004 04:50:00 14.2 1.3 19.5 11.8 13.9 1.3 19.9 10.7 0.4 0 0.4 0.4 64 7 69 305 88 0 88 0 -4.4 0 -4 -4.5 12/05/2004 05:00:00 14.8 1 17.2 12.2 14.5 1.1 16.8 11.8 0.4 0 0.4 0.4 71 6 73 305 88 0 88 0 -4.3 0 -3.8 -4.5 12/05/2004 05:10:00 13.9 1.2 16.4 10.3 13.6 1.3 16.4 9.9 0.4 0 0.4 0.4 69 4 68 305 87 0 87 0 -4.4 0 -4 -4.5 12/05/2004 05:20:00 13.6 1.3 16.4 9.5 13.3 1.4 16.1 8.8 0.4 0 0.4 0.4 69 5 70 305 87 0 87 0 -4.4 0 -3.8 -4.5 12/05/2004 05:30:00 13.8 1 16.4 11.5 13.6 1 16.4 10.7 0.4 0 0.4 0.4 69 5 72 305 87 0 87 0 -4.2 0 -3.8 -4.5 12/05/2004 05:40:00 14.1 0.9 16.4 11.1 13.7 1 16.4 11.1 0.4 0 0.4 0.4 67 4 63 305 86 0 86 0 -4.1 0 -3.6 -4.2 12/05/2004 05:50:00 13.6 1.2 16.4 10.7 13.3 1.2 16.1 9.1 0.4 0 0.4 0.4 69 5 72 305 85 0 85 0 -4.1 0 -3.6 -4.2 12/05/2004 06:00:00 14.2 1.1 16.8 11.1 14 1 17.2 10.7 0.4 0 0.4 0.4 69 5 67 305 85 0 85 0 -4.1 0 -3.6 -4.2 12/05/2004 06:10:00 13.7 1.1 16.4 10.3 13.4 1.2 16.1 9.9 0.4 0 0.4 0.4 72 6 74 305 84 0 84 0 -4.1 0.1 -3.6 -4.2 12/05/2004 06:20:00 14.4 1.1 16.8 11.5 14.2 1.2 16.8 10.7 0.4 0 0.4 0.4 70 4 65 305 83 0 83 0 -4.2 0.1 -3.8 -4.5 12/05/2004 06:30:00 14.6 1 16.4 11.8 14.4 1 16.8 11.5 0.4 0 0.4 0.4 65 4 62 305 83 0 83 0 -4 0 -3.6 -4.2 12/05/2004 06:40:00 14.7 1.1 18.7 11.8 14.4 1.2 18.3 11.1 0.4 0 0.4 0.4 70 5 71 305 82 0 82 0 -4 0 -3.6 -4.2 12/05/2004 06:50:00 14.6 1.2 17.6 11.8 14.4 1.3 17.6 11.8 0.4 0 0.4 0.4 66 6 67 305 82 0 82 0 -4.1 0 -3.6 -4.2 12/05/2004 07:00:00 14.8 1.2 17.6 12.2 14.5 1.2 17.6 11.1 0.4 0 0.4 0.4 64 6 63 305 81 0 81 0 -4 0 -3.3 -4.2 12/05/2004 07:10:00 15.7 1.3 18.3 12.2 15.5 1.3 17.9 11.8 0.4 0 0.4 0.4 63 5 61 305 81 0 81 0 -4 0 -3.6 -4 12/05/2004 07:20:00 15.4 1.2 17.9 12.6 15.2 1.2 17.9 12.6 0.4 0 0.4 0.4 66 6 60 305 80 0 81 0 -4 0 -3.6 -4.2 12/05/2004 07:30:00 16 1.4 18.7 11.8 15.7 1.3 18.7 12.2 0.4 0 0.4 0.4 66 5 69 305 79 0 80 0 -4.1 0 -3.6 -4.2 12/05/2004 07:40:00 16.7 1 19.1 13.7 16.3 1.1 19.1 13.3 0.4 0 0.4 0.4 60 5 56 305 80 0 79 0 -3.9 0 -3.3 -4 12/05/2004 07:50:00 16.5 1.4 19.1 11.5 16.3 1.5 19.1 11.5 0.4 0 0.4 0.4 60 5 49 305 80 0 80 0 -3.9 0 -3.3 -4 12/05/2004 08:00:00 17.1 1.3 19.5 13.3 16.7 1.3 19.5 12.6 0.4 0 0.4 0.4 62 5 65 305 79 0 79 0 -4 0 -3.8 -4 12/05/2004 08:10:00 16.8 1.3 19.5 13.7 16.5 1.3 19.1 13 0.4 0 0.4 0.4 59 5 57 305 79 0 79 0 -4 0 -3.8 -4 12/05/2004 08:20:00 16.6 1.2 19.9 12.2 16.3 1.2 19.9 12.6 0.4 0 0.4 0.4 58 5 50 305 79 0 79 0 -3.9 0 -3.8 -4 12/05/2004 08:30:00 16.6 1.4 19.5 13 16.3 1.4 19.1 12.2 0.4 0 0.4 0.4 62 5 70 305 79 0 79 0 -4 0 -3.8 -4.2 12/05/2004 08:40:00 17.2 1.3 19.9 13.3 16.9 1.3 19.5 13 0.4 0 0.4 0.4 60 5 62 305 78 0 79 0 -4.2 0 -4 -4.2 12/05/2004 08:50:00 16.4 1.5 19.1 11.8 16.1 1.6 18.7 10.7 0.4 0 0.4 0.4 61 5 64 305 78 0 78 0 -4.2 0 -4 -4.2 12/05/2004 09:00:00 16.6 1.1 19.9 13.3 16.3 1.3 19.9 12.6 0.4 0 0.4 0.4 61 5 65 305 77 0 78 0 -4.2 0 -3.6 -4.5 12/05/2004 09:10:00 16.3 1.3 19.5 13.3 16 1.4 19.5 12.2 0.4 0 0.4 0.4 60 5 66 305 77 0 78 0 -4 0 -3.6 -4.2 12/05/2004 09:20:00 16.4 1.3 19.9 13 16.1 1.4 19.5 11.1 0.4 0 0.4 0.4 56 4 54 305 77 0 77 0 -4 0 -3.3 -4 12/05/2004 09:30:00 15.9 1.6 19.5 12.2 15.5 1.7 18.7 11.5 0.4 0 0.4 0.4 60 5 58 305 77 0 77 0 -4 0 -3.6 -4.2 12/05/2004 09:40:00 16 1.1 18.3 13 15.7 1.2 19.1 12.6 0.4 0 0.4 0.4 58 6 59 305 76 0 76 0 -4 0 -3.3 -4 12/05/2004 09:50:00 16.1 1.4 19.5 12.6 15.7 1.5 19.1 12.2 0.4 0 0.4 0.4 56 5 54 305 76 0 76 0 -4 0 -3.3 -4 12/05/2004 10:00:00 16.5 1.2 19.5 12.6 16.1 1.2 19.5 13 0.4 0 0.4 0.4 57 4 56 305 76 0 76 0 -4 0 -3.8 -4 12/05/2004 10:10:00 16.9 1.5 20.2 12.6 16.5 1.5 19.9 12.2 0.4 0 0.4 0.4 58 5 58 305 75 0 75 0 -4 0 -3.8 -4 12/05/2004 10:20:00 16.4 1.4 20.2 12.2 16.1 1.5 19.5 11.5 0.4 0 0.4 0.4 58 5 54 305 74 0 75 0 -4 0 -3.8 -4 12/05/2004 10:30:00 16.8 1.2 19.1 13.3 16.4 1.3 19.1 11.8 0.4 0 0.4 0.4 56 5 60 305 73 0 74 0 -4 0 -3.8 -4 12/05/2004 10:40:00 15.2 1.2 17.6 12.2 14.9 1.3 17.9 11.5 0.4 0 0.4 0.4 60 6 64 305 72 0 73 0 -4 0 -3.8 -4 12/05/2004 10:50:00 15.7 1.2 17.9 11.8 15.4 1.3 18.3 11.1 0.4 0 0.4 0.4 58 6 52 305 72 0 72 0 -4 0 -3.8 -4 12/05/2004 11:00:00 15.6 1.1 17.9 12.2 15.4 1.1 17.9 11.8 0.4 0 0.4 0.4 55 5 48 305 71 0 71 0 -3.9 0 -3.3 -4 12/05/2004 11:10:00 16.3 1.1 18.7 13.3 16 1.2 18.3 12.6 0.4 0 0.4 0.4 55 4 58 305 70 0 69 0 -4 0.1 -3.3 -4.2 12/05/2004 11:20:00 15.6 1.2 18.3 11.8 15.4 1.3 18.3 11.8 0.4 0 0.4 0.4 54 5 53 305 68 0 68 0 -4 0 -3.3 -4.2 12/05/2004 11:30:00 16.2 1.2 19.5 12.6 16 1.3 18.7 12.2 0.4 0 0.4 0.4 54 5 57 305 67 0 68 0 -4 0 -3.3 -4 12/05/2004 11:40:00 15.4 1.5 19.5 12.2 15.1 1.5 19.9 11.5 0.4 0 0.4 0.4 53 5 44 305 67 0 68 0 -3.9 0 -3.3 -4 12/05/2004 11:50:00 16.6 1.1 19.1 13.7 16.4 1.3 19.1 13 0.4 0 0.4 0.4 47 5 46 305 67 0 67 0 -3.9 0 -3.3 -4 12/05/2004 12:00:00 15.6 1.3 18.3 12.6 15.4 1.5 18.3 11.8 0.4 0 0.4 0.4 43 5 47 305 67 0 67 0 -4 0 -3.3 -4.2 12/05/2004 12:10:00 15.9 1.1 19.1 12.6 15.6 1.2 19.5 12.6 0.4 0 0.4 0.4 46 5 45 305 66 0 66 0 -4 0 -3.3 -4.2 12/05/2004 12:20:00 16.4 1.4 19.1 12.6 16.1 1.4 19.1 12.2 0.4 0 0.4 0.4 48 4 50 305 64 0 64 0 -4 0 -3.3 -4.2 12/05/2004 12:30:00 17.1 1.2 19.5 13.7 16.8 1.2 19.5 13.3 0.4 0 0.4 0.4 50 5 37 305 63 1 62 0 -3.9 0 -3.3 -4 12/05/2004 12:40:00 16.3 1.2 19.5 13 16 1.4 19.9 12.2 0.4 0 0.4 0.4 53 5 56 305 60 0 61 0 -4 0 -3.3 -4 12/05/2004 12:50:00 16.3 1.3 19.5 13.3 16.1 1.4 19.1 12.6 0.4 0 0.4 0.4 50 5 48 305 59 0 60 0 -4 0 -3.6 -4.2 12/05/2004 13:00:00 17.1 1 19.5 13.7 16.8 1.1 19.9 13.7 0.4 0 0.4 0.4 50 6 39 305 55 2 53 0 -4.1 0 -3.6 -4.2 12/05/2004 13:10:00 16.4 1.3 19.1 13.3 16.1 1.3 19.1 12.2 0.4 0 0.4 0.4 49 6 48 305 49 1 48 0 -4.1 0 -3.6 -4.2 12/05/2004 13:20:00 17.2 1.3 20.2 13.3 16.9 1.4 19.9 13 0.4 0 0.4 0.4 44 4 45 305 43 2 39 0 -4.1 0 -3.6 -4.2 12/05/2004 13:30:00 16.7 1.5 20.6 13.3 16.5 1.5 19.9 13 0.4 0 0.4 0.4 48 5 42 305 33 3 32 0 -4.1 0 -3.6 -4.2 12/05/2004 13:40:00 16.5 1.4 19.9 13.3 16.1 1.5 19.5 12.6 0.4 0 0.4 0.4 47 6 47 305 24 3 23 0 -4.1 0.1 -3.6 -4.5 12/05/2004 13:50:00 17 1.2 19.5 13.7 16.7 1.2 19.1 13 0.4 0 0.4 0.4 49 5 45 305 15 2 15 0 -4.2 0 -3.8 -4.5 12/05/2004 14:00:00 17.7 1.5 21 13.3 17.4 1.5 20.6 13.3 0.4 0 0.4 0.4 47 6 45 305 10 1 11 0 -4.2 0.1 -3.8 -4.5 12/05/2004 14:10:00 17.2 1.3 19.9 13.7 16.9 1.3 19.5 13.7 0.4 0 0.4 0.4 47 5 43 305 7 1 8 0 -4.3 0.1 -3.8 -4.5 12/05/2004 14:20:00 17.5 1.3 20.6 14.1 17.1 1.4 20.6 12.2 0.4 0 0.4 0.4 46 5 46 305 5 0 5 0 -4.4 0 -3.8 -4.7 12/05/2004 14:30:00 17.5 1.4 20.2 13.7 17.2 1.4 20.2 13.3 0.4 0 0.4 0.4 50 4 50 305 4 0 4 0 -4.6 0 -4 -4.7 12/05/2004 14:40:00 16.4 1.5 20.2 12.6 16.2 1.5 19.9 11.8 0.4 0 0.4 0.4 49 6 47 305 4 0 4 0 -4.5 0 -4 -4.7 12/05/2004 14:50:00 17.4 1.2 20.6 14.5 17.2 1.3 20.2 13.7 0.4 0 0.4 0.4 50 5 47 305 3 0 3 0 -4.6 0 -4.2 -4.7 12/05/2004 15:00:00 16.6 1.3 19.9 13.3 16.4 1.4 19.1 12.6 0.4 0 0.4 0.4 46 6 42 305 3 0 3 0 -4.6 0 -4 -4.7 12/05/2004 15:10:00 17 1.3 19.9 13.7 16.7 1.4 20.2 13 0.4 0 0.4 0.4 45 6 42 305 3 0 3 0 -4.7 0.1 -4 -4.9 12/05/2004 15:20:00 17.7 1.3 21 13.3 17.5 1.5 21 13.3 0.4 0 0.4 0.4 45 5 43 305 3 0 3 0 -4.7 0.1 -4.2 -4.9 12/05/2004 15:30:00 18.1 1.1 20.6 14.1 17.8 1.3 20.6 13.7 0.4 0 0.4 0.4 43 4 43 305 3 0 3 0 -4.9 0 -4.5 -4.9 12/05/2004 15:40:00 18.1 1 20.2 14.1 17.9 1.1 20.6 14.1 0.4 0 0.4 0.4 44 5 41 305 3 0 3 0 -4.9 0 -4.2 -5.1 12/05/2004 15:50:00 17.7 1.3 20.2 14.9 17.5 1.3 20.6 13.7 0.4 0 0.4 0.4 44 4 46 305 3 0 3 0 -4.9 0 -4.5 -5.1 12/05/2004 16:00:00 17.8 1.2 21.4 14.5 17.6 1.3 20.6 12.6 0.4 0 0.4 0.4 43 5 45 305 3 0 4 0 -4.9 0 -4.5 -5.1 12/05/2004 16:10:00 18.8 1.4 21.8 13.7 18.6 1.4 22.1 14.5 0.4 0 0.4 0.4 36 4 37 305 4 0 5 0 -5 0 -4.5 -5.3 12/05/2004 16:20:00 18.9 1.3 21.8 14.1 18.7 1.3 21.8 14.5 0.4 0 0.4 0.4 38 5 40 305 5 0 5 0 -5.2 0 -4.7 -5.6 12/05/2004 16:30:00 19.6 1.4 23.3 15.3 19.1 1.5 22.6 14.9 0.4 0 0.4 0.4 34 4 34 305 6 0 7 0 -5.3 0.1 -5.1 -5.6 12/05/2004 16:40:00 20.5 1.2 23.3 16.1 20.2 1.4 22.9 15.6 0.4 0 0.4 0.4 38 5 37 305 8 0 8 0 -5.7 0 -5.3 -6 12/05/2004 16:50:00 20.3 1.3 23.7 16.1 19.9 1.3 22.6 15.6 0.4 0 0.4 0.4 42 6 35 305 8 0 8 0 -5.9 0.1 -5.6 -6 12/05/2004 17:00:00 19.8 1.5 22.9 15.6 19.5 1.5 22.6 15.3 0.4 0 0.4 0.4 41 5 44 305 7 0 7 0 -5.9 0 -5.6 -6.2 12/05/2004 17:10:00 20.9 1.5 24.4 16.8 20.7 1.6 24 15.6 0.4 0 0.4 0.4 40 4 42 305 6 0 6 0 -6.2 0 -6 -6.4 12/05/2004 17:20:00 20.6 1.7 24.4 15.6 20.3 1.7 24.4 15.3 0.4 0 0.4 0.4 39 6 45 305 5 0 5 0 -6.2 0 -6 -6.4 12/05/2004 17:30:00 21.4 1.9 25.6 16.1 21 2.1 26 16.4 0.4 0 0.4 0.4 41 5 44 305 5 0 5 0 -6.4 0.1 -6 -6.7 12/05/2004 17:40:00 21.9 1.6 26 17.6 21.5 1.7 25.6 17.6 0.4 0 0.4 0.4 34 5 29 305 4 0 4 0 -6.4 0.1 -6.2 -6.7 12/05/2004 17:50:00 21.8 1.6 26.3 17.6 21.4 1.7 25.6 16.1 0.4 0 0.4 0.4 34 6 36 305 4 1 4 0 -6.5 0 -6.2 -6.7 12/05/2004 18:00:00 22.9 1.7 26.3 16.8 22.6 1.8 26.3 18.3 0.4 0 0.4 0.4 39 5 30 305 7 1 7 0 -6.5 0 -6 -6.9 12/05/2004 18:10:00 23 1.6 26.3 17.6 22.7 1.7 26.8 17.6 0.4 0 0.4 0.4 44 4 45 305 11 1 10 0 -6.7 0 -6.2 -6.9 12/05/2004 18:20:00 22.2 1.8 25.2 16.8 21.8 2 26 16.8 0.4 0 0.4 0.4 40 4 38 305 17 2 14 0 -6.8 0 -6.2 -6.9 12/05/2004 18:30:00 22.1 1.9 26 16.1 21.7 2.1 26.3 15.6 0.4 0 0.4 0.4 37 5 32 305 22 1 21 0 -6.7 0 -6.2 -6.9 12/05/2004 18:40:00 23.6 1.7 27.5 17.9 23.2 1.7 27.5 17.9 0.4 0 0.4 0.4 34 4 36 305 25 0 25 0 -6.8 0 -6.2 -6.9 12/05/2004 18:50:00 23.6 1.7 27.1 17.6 23.2 1.8 27.1 18.3 0.4 0 0.4 0.4 36 5 36 305 23 1 24 0 -6.9 0 -6.2 -7.1 12/05/2004 19:00:00 23.2 1.8 27.1 17.9 22.7 2 26.8 17.6 0.4 0 0.4 0.4 37 5 32 305 20 1 21 0 -6.8 0 -6.2 -7.1 12/05/2004 19:10:00 22.9 2 27.5 17.6 22.5 2.1 27.1 15.6 0.4 0 0.4 0.4 39 5 44 305 17 1 18 0 -6.8 0.1 -6.2 -7.1 12/05/2004 19:20:00 22 1.7 27.1 18.3 21.6 1.7 25.6 17.6 0.4 0 0.4 0.4 40 5 44 305 14 1 13 0 -6.8 0 -6.7 -7.1 12/05/2004 19:30:00 22.7 1.7 26.8 18.3 22.2 1.8 26.8 17.2 0.4 0 0.4 0.4 37 5 39 305 11 1 11 0 -7 0.1 -6.7 -7.3 12/05/2004 19:40:00 21.5 2.2 26.8 16.1 21.1 2.2 26.8 16.1 0.4 0 0.4 0.4 38 6 43 305 9 0 9 0 -6.8 0.1 -6.4 -7.1 12/05/2004 19:50:00 22.2 1.8 26.8 17.6 21.8 1.8 26.3 17.2 0.4 0 0.4 0.4 34 7 32 305 7 0 7 0 -6.8 0 -6.4 -6.9 12/05/2004 20:00:00 22.2 1.9 26.8 17.6 21.9 2 26.8 17.6 0.4 0 0.4 0.4 40 6 48 305 6 0 6 0 -6.9 0 -6.7 -7.1 12/05/2004 20:10:00 21.8 1.9 26.3 16.1 21.3 2.1 26.3 14.9 0.4 0 0.4 0.4 40 6 41 305 5 0 5 0 -6.8 0.1 -6.7 -7.1 12/05/2004 20:20:00 22.6 1.7 26 17.9 22.2 1.9 26.3 16.8 0.4 0 0.4 0.4 38 6 33 305 4 0 4 0 -6.8 0.1 -6.7 -7.1 12/05/2004 20:30:00 21.7 1.6 24.8 17.6 21.3 1.5 24.8 16.4 0.4 0 0.4 0.4 35 6 38 305 3 0 3 0 -6.9 0 -6.7 -7.1 12/05/2004 20:40:00 21.2 2 25.6 15.3 20.9 2 25.2 14.9 0.4 0 0.4 0.4 39 6 43 305 3 0 3 0 -6.9 0 -6.7 -7.1 12/05/2004 20:50:00 20.8 1.7 25.2 16.8 20.5 1.8 24.4 15.6 0.4 0 0.4 0.4 43 5 45 305 2 0 2 0 -6.9 0 -6.7 -7.1 12/05/2004 21:00:00 21.1 1.7 25.2 16.1 20.7 1.8 25.2 16.1 0.4 0 0.4 0.4 39 5 42 305 2 0 2 0 -6.9 0.1 -6.7 -7.1 12/05/2004 21:10:00 21.3 1.7 25.2 15.6 20.9 1.8 25.2 14.5 0.4 0 0.4 0.4 42 5 46 305 2 0 2 0 -7 0 -6.9 -7.1 12/05/2004 21:20:00 21.8 1.7 25.2 16.8 21.3 1.8 25.2 16.8 0.4 0 0.4 0.4 44 5 46 305 1 0 1 0 -7.1 0 -6.7 -7.3 12/05/2004 21:30:00 21 1.8 25.6 16.4 20.6 1.8 25.2 16.4 0.4 0 0.4 0.4 43 6 46 305 1 0 1 0 -7 0 -6.7 -7.1 12/05/2004 21:40:00 21.7 1.5 24.8 17.2 21.4 1.5 24.4 16.4 0.4 0 0.4 0.4 43 5 38 305 1 0 1 0 -7 0 -6.9 -7.1 12/05/2004 21:50:00 20.6 2 26 15.3 20.3 2.1 25.6 14.9 0.4 0 0.4 0.4 41 6 48 305 1 0 1 0 -7 0.1 -6.7 -7.1 12/05/2004 22:00:00 20.9 1.7 24.8 16.4 20.5 1.8 24 15.3 0.4 0 0.4 0.4 42 5 50 305 1 0 1 0 -7 0 -6.7 -7.1 12/05/2004 22:10:00 20.3 1.7 24 15.3 20 1.8 24.4 15.6 0.4 0 0.4 0.4 38 5 38 305 1 0 1 0 -6.9 0.1 -6.7 -7.1 12/05/2004 22:20:00 20.8 1.9 25.2 15.6 20.4 2 24.4 15.3 0.4 0 0.4 0.4 40 5 46 305 1 0 1 0 -6.9 0 -6.7 -7.1 12/05/2004 22:30:00 20.5 1.5 23.3 15.3 20.1 1.5 24 14.9 0.4 0 0.4 0.4 43 5 39 305 1 0 1 0 -6.9 0 -6.7 -7.1 12/05/2004 22:40:00 19.7 1.7 23.3 15.6 19.4 1.8 23.3 14.9 0.4 0 0.4 0.4 35 6 36 305 1 0 1 0 -6.5 0.1 -6.2 -6.9 12/05/2004 22:50:00 21.4 1.5 24.4 15.6 21 1.6 24.4 16.4 0.4 0 0.4 0.4 30 5 31 305 1 0 1 0 -6.6 0 -6.2 -6.9 12/05/2004 23:00:00 20 1.7 25.2 16.1 19.7 1.7 24.8 15.6 0.4 0 0.4 0.4 33 6 41 305 1 0 1 0 -6.6 0 -6.2 -6.9 12/05/2004 23:10:00 20.8 1.7 24.4 16.1 20.5 1.7 24.8 15.6 0.4 0 0.4 0.4 30 5 32 305 1 0 1 0 -6.7 0 -6.4 -6.9 12/05/2004 23:20:00 21.1 1.7 25.2 16.1 20.7 1.9 24.4 14.5 0.4 0 0.4 0.4 32 5 32 305 1 0 1 0 -6.8 0 -6.7 -7.1 12/05/2004 23:30:00 21 1.5 24.8 17.2 20.8 1.6 24.8 16.4 0.4 0 0.4 0.4 33 5 36 305 1 0 1 0 -6.9 0 -6.7 -7.1 12/05/2004 23:40:00 20.7 1.7 25.2 15.3 20.3 1.8 24.8 15.6 0.4 0 0.4 0.4 32 6 32 305 1 0 1 0 -7 0.1 -6.7 -7.3 12/05/2004 23:50:00 20.4 1.6 24 16.1 20 1.7 24.4 15.3 0.4 0 0.4 0.4 30 5 29 305 1 0 1 0 -7.1 0 -6.9 -7.3 12/06/2004 00:00:00 20.2 1.7 24.4 16.4 19.9 1.8 23.7 15.6 0.4 0 0.4 0.4 34 6 22 305 1 0 1 0 -7.1 0 -6.9 -7.3 12/06/2004 00:10:00 20.7 1.7 24.8 15.6 20.5 1.7 25.2 16.1 0.4 0 0.4 0.4 29 6 29 305 1 0 1 0 -7.2 0 -7.1 -7.5 12/06/2004 00:20:00 20 1.7 23.7 15.3 19.6 1.7 23.7 14.1 0.4 0 0.4 0.4 33 6 26 305 1 0 1 0 -7 0.1 -6.7 -7.3 12/06/2004 00:30:00 20.8 1.7 24.8 16.4 20.5 1.7 25.2 16.1 0.4 0 0.4 0.4 31 6 35 305 1 0 1 0 -7 0 -6.9 -7.3 12/06/2004 00:40:00 21.6 1.7 26 17.2 21.3 1.7 25.6 16.4 0.4 0 0.4 0.4 33 4 35 305 1 0 1 0 -7.1 0 -6.9 -7.3 12/06/2004 00:50:00 21.9 2 26 15.6 21.5 2.1 26 14.9 0.4 0 0.4 0.4 29 5 30 305 1 0 1 0 -7.1 0 -6.9 -7.3 12/06/2004 01:00:00 23.1 1.8 26.3 17.2 22.8 1.8 26.8 16.4 0.4 0 0.4 0.4 30 5 24 305 1 0 1 0 -7.2 0 -7.1 -7.5 12/06/2004 01:10:00 22.1 2 26 16.1 21.7 2 26 16.1 0.4 0 0.4 0.4 33 6 29 305 1 0 1 0 -7.2 0 -6.9 -7.5 12/06/2004 01:20:00 22.3 1.9 25.2 16.4 21.9 2.1 25.6 15.3 0.4 0 0.4 0.4 32 6 38 305 1 0 1 0 -7.5 0 -7.1 -7.7 12/06/2004 01:30:00 21.7 2.3 26 14.5 21.3 2.4 26 14.1 0.4 0 0.4 0.4 33 5 33 305 2 0 2 0 -7.2 0 -6.9 -7.5 12/06/2004 01:40:00 21 2 25.2 16.4 20.7 2 25.2 15.3 0.4 0 0.4 0.4 32 5 33 305 2 0 2 0 -7.2 0 -7.1 -7.5 12/06/2004 01:50:00 21.4 1.8 26 16.1 20.9 1.9 25.6 15.6 0.4 0 0.4 0.4 35 6 33 305 2 0 2 0 -7.1 0 -6.9 -7.3 12/06/2004 02:00:00 22.1 1.7 26 16.8 21.6 1.7 25.6 17.2 0.4 0 0.4 0.4 36 5 40 305 2 0 2 0 -7 0 -6.9 -7.3 12/06/2004 02:10:00 22.3 1.7 26.3 17.2 21.9 1.7 25.6 16.8 0.4 0 0.4 0.4 34 7 37 305 2 0 2 0 -6.9 0 -6.7 -7.1 12/06/2004 02:20:00 23.6 1.4 26.8 18.3 23.1 1.5 26 17.6 0.4 0 0.4 0.4 35 5 36 305 2 0 2 0 -6.9 0 -6.7 -6.9 12/06/2004 02:30:00 22.1 2.2 26.8 16.4 21.6 2.3 26.8 16.1 0.4 0 0.4 0.4 31 6 41 305 2 0 2 0 -6.8 0 -6.7 -7.1 12/06/2004 02:40:00 21 2.1 25.6 16.4 20.5 2.3 25.6 15.3 0.4 0 0.4 0.4 35 6 44 305 2 0 2 0 -6.9 0.1 -6.7 -7.1 12/06/2004 02:50:00 22.6 1.7 26.3 17.2 22.4 1.8 26.8 17.2 0.4 0 0.4 0.4 38 5 37 305 2 0 2 0 -7.2 0 -6.9 -7.5 12/06/2004 03:00:00 22.2 1.5 26 17.9 21.8 1.7 25.6 17.2 0.4 0 0.4 0.4 36 5 37 305 2 0 2 0 -7.4 0 -7.1 -7.7 12/06/2004 03:10:00 22.2 1.8 26.3 16.4 21.8 2 26 16.4 0.4 0 0.4 0.4 28 5 37 305 2 0 2 0 -7.4 0 -7.1 -7.7 12/06/2004 03:20:00 22.2 1.9 27.1 17.6 21.9 2 27.1 17.2 0.4 0 0.4 0.4 26 5 27 305 3 0 3 0 -7.4 0.1 -7.1 -7.7 12/06/2004 03:30:00 23 2.6 27.5 15.6 22.6 2.6 28.3 16.1 0.4 0 0.4 0.4 33 5 35 305 3 0 3 0 -7.7 0.1 -7.3 -7.9 12/06/2004 03:40:00 22.3 2.1 26.3 16.1 21.9 2.2 26.3 16.4 0.4 0 0.4 0.4 31 5 27 305 3 0 3 0 -7.7 0 -7.3 -7.9 12/06/2004 03:50:00 21.6 2.1 26 16.4 21.2 2.2 25.6 15.3 0.4 0 0.4 0.4 35 6 32 305 3 0 3 0 -7.6 0.1 -7.3 -7.9 12/06/2004 04:00:00 22.2 2.3 26.8 16.1 21.9 2.5 26.8 14.9 0.4 0 0.4 0.4 34 5 34 305 2 0 2 0 -7.6 0.1 -7.1 -7.7 12/06/2004 04:10:00 23.7 1.7 27.5 18.3 23.3 1.8 27.1 17.2 0.4 0 0.4 0.4 36 5 43 305 2 0 2 0 -7.6 0 -7.5 -7.7 12/06/2004 04:20:00 23 2.3 27.9 16.8 22.6 2.4 27.9 17.2 0.4 0 0.4 0.4 35 5 38 305 2 0 2 0 -7.5 0.1 -7.3 -7.7 12/06/2004 04:30:00 23.5 2.3 28.7 16.8 23.1 2.4 29.1 16.1 0.4 0 0.4 0.4 33 6 35 305 2 0 2 0 -7.7 0 -7.3 -7.9 12/06/2004 04:40:00 23.4 2 27.5 18.3 23 2.1 27.5 17.6 0.4 0 0.4 0.4 34 7 38 305 2 0 2 0 -7.8 0.1 -7.3 -8.2 12/06/2004 04:50:00 23.3 1.7 27.5 17.9 23 1.7 27.1 17.6 0.4 0 0.4 0.4 28 6 27 305 1 0 2 0 -7.8 0 -7.7 -7.9 12/06/2004 05:00:00 23.4 2 27.5 17.6 22.9 2.2 27.5 16.4 0.4 0 0.4 0.4 34 5 33 305 1 0 1 0 -7.8 0.1 -7.3 -8.2 12/06/2004 05:10:00 23.3 1.7 26.8 17.9 22.8 2 27.1 17.2 0.4 0 0.4 0.4 38 5 43 305 1 0 2 0 -7.7 0 -7.5 -7.9 12/06/2004 05:20:00 22.7 2.4 27.1 16.4 22.3 2.6 27.5 15.3 0.4 0 0.4 0.4 33 6 22 305 1 0 1 0 -7.5 0.1 -6.9 -7.7 12/06/2004 05:30:00 22.2 1.9 26.8 17.6 21.9 1.9 26.3 15.6 0.4 0 0.4 0.4 35 5 28 305 2 0 1 0 -7.1 0 -6.9 -7.3 12/06/2004 05:40:00 22.1 2.1 26 16.4 21.8 2.2 26 16.4 0.4 0 0.4 0.4 35 6 38 305 1 0 1 0 -7 0.1 -6.9 -7.3 12/06/2004 05:50:00 22.1 2.5 27.5 16.1 21.7 2.5 27.5 15.6 0.4 0 0.4 0.4 34 6 39 305 1 0 1 0 -6.7 0.2 -6.2 -7.1 12/06/2004 06:00:00 22.2 2.2 27.5 15.3 21.8 2.2 26.3 15.6 0.4 0 0.4 0.4 29 5 30 305 1 0 1 0 -6.5 0.1 -6.2 -6.9 12/06/2004 06:10:00 21.5 1.8 25.6 16.8 21 1.9 25.2 16.4 0.4 0 0.4 0.4 32 6 18 305 1 0 1 0 -6.4 0 -6.2 -6.7 12/06/2004 06:20:00 21.2 1.6 25.2 17.6 20.8 1.7 25.2 16.8 0.4 0 0.4 0.4 34 5 33 305 1 0 1 0 -6.4 0.1 -6.2 -6.7 12/06/2004 06:30:00 20.8 1.6 24 16.1 20.4 1.7 24.8 15.6 0.4 0 0.4 0.4 30 5 39 305 2 0 2 0 -6.3 0.1 -6 -6.7 12/06/2004 06:40:00 21.3 2.2 25.2 16.1 20.8 2.2 25.6 14.9 0.4 0 0.4 0.4 30 4 31 305 2 0 2 0 -6.3 0.1 -5.8 -6.7 12/06/2004 06:50:00 21.4 1.9 26 16.1 21 2 26 15.3 0.4 0 0.4 0.4 29 5 24 305 2 0 2 0 -6.4 0.1 -6 -6.7 12/06/2004 07:00:00 21 1.7 25.6 16.4 20.8 1.7 24.4 16.1 0.4 0 0.4 0.4 29 5 22 305 2 0 2 0 -6.3 0 -6.2 -6.7 12/06/2004 07:10:00 21.3 1.7 25.2 16.1 20.8 1.8 24.8 15.6 0.4 0 0.4 0.4 31 6 28 305 2 0 2 0 -6.3 0 -6 -6.7 12/06/2004 07:20:00 21.5 1.6 25.6 17.2 21.2 1.7 26 15.3 0.4 0 0.4 0.4 34 6 37 305 2 0 2 0 -6.5 0 -6.2 -6.7 12/06/2004 07:30:00 21.4 1.5 24.8 17.2 21 1.6 24.8 16.4 0.4 0 0.4 0.4 34 6 37 305 2 0 2 0 -6.4 0.1 -6 -6.7 12/06/2004 07:40:00 21 1.7 25.2 16.1 20.6 1.7 24.8 16.1 0.4 0 0.4 0.4 33 6 28 305 2 0 2 0 -6.4 0 -6 -6.7 12/06/2004 07:50:00 21.1 2.3 25.6 15.6 20.6 2.4 25.6 14.5 0.4 0 0.4 0.4 36 6 39 305 1 0 1 0 -6.2 0.1 -6 -6.7 12/06/2004 08:00:00 20.1 1.6 24.4 15.3 19.8 1.6 23.7 15.6 0.4 0 0.4 0.4 29 7 35 305 1 0 1 0 -6.1 0 -5.8 -6.2 12/06/2004 08:10:00 19.3 2.3 24.8 14.5 19.1 2.3 24.8 14.5 0.4 0 0.4 0.4 22 8 16 305 3 1 2 0 -6.6 0.2 -6 -6.9 12/06/2004 08:20:00 19.9 2 23.7 14.1 19.7 2.1 24 13 0.4 0 0.4 0.4 33 6 30 305 12 4 17 0 -6.6 0 -6.4 -6.9 12/06/2004 08:30:00 19.7 1.5 22.6 15.3 19.5 1.5 22.9 14.5 0.4 0 0.4 0.4 29 5 22 305 28 5 24 0 -6.5 0 -6.2 -6.7 12/06/2004 08:40:00 19.6 1.5 22.9 15.6 19.4 1.5 22.9 15.3 0.4 0 0.4 0.4 35 5 38 305 43 3 40 0 -6.5 0 -6.2 -6.7 12/06/2004 08:50:00 18.9 2.3 24 13.7 18.6 2.5 24 12.2 0.4 0 0.4 0.4 34 5 33 305 51 2 54 0 -6.4 0.1 -6.2 -6.7 12/06/2004 09:00:00 20 1.6 23.3 15.6 19.8 1.5 23.7 15.6 0.4 0 0.4 0.4 32 7 35 305 57 2 58 0 -6.4 0 -6.2 -6.7 12/06/2004 09:10:00 19.5 1.7 22.9 14.9 19.3 1.7 22.9 14.1 0.4 0 0.4 0.4 34 6 32 305 62 1 64 0 -6.5 0.1 -6 -6.9 12/06/2004 09:20:00 21.3 1.7 24.4 16.4 21 1.7 24.4 15.3 0.4 0 0.4 0.4 29 6 33 305 66 1 66 0 -6.8 0 -6.7 -6.9 12/06/2004 09:30:00 20.4 1.7 24.8 15.6 20 1.7 24 14.9 0.4 0 0.4 0.4 31 5 33 305 68 1 67 0 -6.7 0 -6.4 -6.9 12/06/2004 09:40:00 20.2 1.8 25.2 15.6 19.9 1.8 25.2 15.6 0.4 0 0.4 0.4 32 6 28 305 70 0 71 0 -6.8 0 -6.7 -7.1 12/06/2004 09:50:00 21.1 1.6 24.4 16.1 20.7 1.7 24.4 16.1 0.4 0 0.4 0.4 28 5 31 305 72 0 73 0 -6.8 0 -6.7 -7.1 12/06/2004 10:00:00 21 2.3 26 14.9 20.6 2.4 26 14.9 0.4 0 0.4 0.4 32 6 31 305 73 0 73 0 -6.8 0.1 -6.4 -7.1 12/06/2004 10:10:00 21.7 2.2 26.3 16.4 21.2 2.2 26.3 16.4 0.4 0 0.4 0.4 28 6 31 305 74 0 74 0 -6.8 0.1 -6.7 -7.1 12/06/2004 10:20:00 22.2 1.8 26.3 16.8 21.8 1.9 26 16.4 0.4 0 0.4 0.4 28 5 28 305 75 0 75 0 -6.9 0.1 -6.7 -7.1 12/06/2004 10:30:00 23.4 1.8 27.1 17.2 23 1.9 28.3 16.8 0.4 0 0.4 0.4 29 5 22 305 75 0 75 0 -6.9 0 -6.7 -7.1 12/06/2004 10:40:00 21.5 1.8 25.2 16.1 21.2 2 25.2 15.6 0.4 0 0.4 0.4 30 6 35 305 75 0 76 0 -6.8 0 -6.7 -7.1 12/06/2004 10:50:00 22.3 1.8 26.3 16.4 22 1.9 26.8 16.8 0.4 0 0.4 0.4 29 5 30 305 76 0 76 0 -6.7 0.1 -6.4 -6.9 12/06/2004 11:00:00 21.9 1.9 26.3 15.3 21.6 1.9 26.8 16.4 0.4 0 0.4 0.4 32 5 32 305 76 0 76 0 -6.5 0.1 -6.2 -6.7 12/06/2004 11:10:00 22.6 1.6 26.3 17.9 22.3 1.7 26.8 16.8 0.4 0 0.4 0.4 33 5 39 305 76 0 76 0 -6.5 0 -6.2 -6.7 12/06/2004 11:20:00 21.4 1.8 25.6 16.4 21 1.9 25.6 15.6 0.4 0 0.4 0.4 28 5 32 305 76 0 77 0 -6.3 0.1 -6 -6.7 12/06/2004 11:30:00 21.7 2.1 25.6 15.6 21.3 2.1 26.3 15.3 0.4 0 0.4 0.4 27 5 18 305 76 0 76 0 -6.3 0 -6 -6.7 12/06/2004 11:40:00 21.6 2.1 26 13.7 21.2 2.2 25.2 13 0.4 0 0.4 0.4 29 5 25 305 75 0 76 0 -6.3 0 -6 -6.4 12/06/2004 11:50:00 20.9 1.9 24.8 14.9 20.7 1.7 24.4 16.1 0.4 0 0.4 0.4 29 5 30 305 74 0 75 0 -6.1 0 -5.8 -6.2 12/06/2004 12:00:00 21.7 1.8 25.6 16.4 21.4 1.9 25.6 16.4 0.4 0 0.4 0.4 27 5 29 305 73 0 74 0 -6 0 -5.8 -6.2 12/06/2004 12:10:00 20 1.8 24.8 15.3 19.8 1.8 25.2 15.3 0.4 0 0.4 0.4 23 5 18 305 72 0 73 0 -5.8 0.1 -5.3 -6 12/06/2004 12:20:00 21.2 1.8 24.8 16.8 20.9 2 25.6 15.6 0.4 0 0.4 0.4 28 8 36 305 74 1 76 0 -6.4 0.1 -6 -6.7 12/06/2004 12:30:00 20.9 1.6 25.2 15.6 20.4 1.7 24.8 14.9 0.4 0 0.4 0.4 26 5 29 305 77 0 76 0 -6.4 0.1 -6 -6.9 12/06/2004 12:40:00 19.9 1.6 23.3 15.6 19.5 1.7 23.7 14.9 0.4 0 0.4 0.4 31 5 28 305 79 0 79 0 -6.2 0 -6 -6.4 12/06/2004 12:50:00 19.3 1.5 22.9 15.6 19.1 1.7 23.3 14.9 0.4 0 0.4 0.4 25 7 17 305 80 0 80 0 -6.4 0.1 -6 -6.7 12/06/2004 13:00:00 19.6 1.6 23.3 15.6 19.4 1.7 24 15.3 0.4 0 0.4 0.4 24 6 33 305 80 0 80 0 -6.2 0 -6 -6.4 12/06/2004 13:10:00 20.1 2 24.8 14.5 19.8 2 24.4 14.9 0.4 0 0.4 0.4 23 6 19 305 80 0 81 0 -6.4 0.1 -6 -6.7 12/06/2004 13:20:00 20.7 1.9 24.8 15.6 20.5 1.9 24.8 15.6 0.4 0 0.4 0.4 21 9 15 305 81 0 81 0 -6.5 0.1 -6.2 -6.9 12/06/2004 13:30:00 20.7 1.9 26 16.1 20.3 2 26 15.3 0.4 0 0.4 0.4 28 8 31 305 81 0 81 0 -6.3 0.1 -6 -6.7 12/06/2004 13:40:00 21.7 1.8 26.8 17.6 21.4 1.8 25.6 17.2 0.4 0 0.4 0.4 26 8 29 305 81 0 81 0 -6.3 0 -6 -6.7 12/06/2004 13:50:00 22 1.6 25.6 17.6 21.6 1.7 25.6 16.1 0.4 0 0.4 0.4 33 6 36 305 81 0 81 0 -6.2 0 -6 -6.4 12/06/2004 14:00:00 22.8 2.5 28.3 16.4 22.2 2.5 27.9 16.4 0.4 0 0.4 0.4 30 5 30 305 81 0 81 0 -6.2 0 -6 -6.4 12/06/2004 14:10:00 23 2.4 28.7 17.2 22.6 2.4 27.9 17.6 0.4 0 0.4 0.4 29 6 32 305 81 0 81 0 -6.2 0 -6 -6.4 12/06/2004 14:20:00 24.1 1.8 28.3 19.9 23.5 1.9 27.5 18.3 0.4 0 0.4 0.4 30 6 42 305 81 0 81 0 -6.5 0.1 -6 -6.9 12/06/2004 14:30:00 23 2.2 28.7 17.6 22.6 2.2 28.3 17.2 0.4 0 0.4 0.4 25 5 21 305 81 0 81 0 -6.5 0.1 -6.2 -6.9 12/06/2004 14:40:00 23.5 1.7 27.5 16.8 23.1 1.9 27.5 16.4 0.4 0 0.4 0.4 24 5 24 305 81 0 82 0 -6.4 0 -6.2 -6.7 12/06/2004 14:50:00 21.5 2 26 15.6 21.3 1.8 26.3 16.4 0.4 0 0.4 0.4 28 5 23 305 82 0 82 0 -6.2 0 -6 -6.7 12/06/2004 15:00:00 23.3 1.9 26.3 17.6 22.8 2.1 26.3 16.8 0.4 0 0.4 0.4 23 5 25 305 82 0 82 0 -6.2 0 -6 -6.4 12/06/2004 15:10:00 22.8 2.4 27.9 16.4 22.4 2.5 28.3 16.4 0.4 0 0.4 0.4 26 5 21 305 82 0 82 0 -6.2 0 -5.8 -6.4 12/06/2004 15:20:00 22.9 1.7 27.5 17.9 22.5 1.8 27.5 17.9 0.4 0 0.4 0.4 25 6 23 305 82 0 82 0 -6.1 0 -6 -6.2 12/06/2004 15:30:00 21.7 1.9 26.3 16.8 21.2 2.1 25.6 15.3 0.4 0 0.4 0.4 26 5 27 305 82 0 82 0 -6.1 0 -5.8 -6.4 12/06/2004 15:40:00 21.4 2 26 15.3 21 2.1 25.6 14.9 0.4 0 0.4 0.4 26 5 21 305 82 0 83 0 -6.1 0 -5.8 -6.4 12/06/2004 15:50:00 21.5 1.7 25.6 16.4 21.3 1.8 25.2 16.4 0.4 0 0.4 0.4 26 5 26 305 83 0 82 0 -6.1 0 -6 -6.4 12/06/2004 16:00:00 21.9 1.7 25.6 17.2 21.5 1.7 26 16.8 0.4 0 0.4 0.4 28 5 31 305 83 0 83 0 -6.1 0 -5.8 -6.2 12/06/2004 16:10:00 20.4 1.9 25.6 15.6 20.1 2 26 15.3 0.4 0 0.4 0.4 30 6 34 305 83 0 83 0 -6 0 -5.8 -6.2 12/06/2004 16:20:00 21.5 1.9 25.2 15.6 21.2 2 25.6 14.1 0.4 0 0.4 0.4 26 5 26 305 83 0 83 0 -5.9 0.1 -5.6 -6 12/06/2004 16:30:00 21.9 1.7 26.3 16.8 21.7 1.8 26.3 16.8 0.4 0 0.4 0.4 20 5 12 305 84 0 84 0 -6.4 0.2 -6 -6.9 12/06/2004 16:40:00 23.6 2.2 27.5 17.9 23.5 2.3 28.7 18.3 0.4 0 0.4 0.4 14 5 19 305 84 0 84 0 -6.6 0 -6.4 -6.9 12/06/2004 16:50:00 22 2.6 26.8 15.6 21.9 2.6 27.1 15.6 0.4 0 0.4 0.4 14 5 12 305 84 0 84 0 -6.4 0.1 -6 -6.7 12/06/2004 17:00:00 23.3 2 27.9 16.1 23.2 2.1 28.7 16.1 0.4 0 0.4 0.4 14 5 19 305 84 0 84 0 -6.5 0 -6.2 -6.7 12/06/2004 17:10:00 23 1.5 26.3 18.7 22.8 1.7 26.8 17.9 0.4 0 0.4 0.4 16 6 17 305 84 0 84 0 -6.5 0 -6.2 -6.9 12/06/2004 17:20:00 22.8 1.7 26.8 16.4 22.4 1.9 26.3 16.1 0.4 0 0.4 0.4 13 4 13 305 84 0 84 0 -6.6 0 -6.2 -6.9 12/06/2004 17:30:00 22.1 2.1 26 15.6 21.8 2.1 26.3 16.1 0.4 0 0.4 0.4 17 5 19 305 83 0 84 0 -6.7 0.1 -6.2 -6.9 12/06/2004 17:40:00 21.5 2.1 26.8 16.8 21.2 2.2 27.1 14.9 0.4 0 0.4 0.4 14 6 14 305 84 0 84 0 -6.4 0.1 -6 -6.9 12/06/2004 17:50:00 22 1.9 26.3 17.6 21.7 1.9 26.8 16.8 0.4 0 0.4 0.4 14 5 15 305 84 0 84 0 -6.3 0.1 -6 -6.7 12/06/2004 18:00:00 22.2 2 27.1 16.8 21.8 2 27.1 15.6 0.4 0 0.4 0.4 11 6 14 305 83 0 84 0 -6.3 0 -6 -6.7 12/06/2004 18:10:00 22.2 1.7 25.6 17.9 21.9 1.9 26.3 17.2 0.4 0 0.4 0.4 11 5 13 305 83 0 83 0 -6.5 0 -6.2 -6.7 12/06/2004 18:20:00 21.7 1.7 25.6 16.1 21.4 1.8 26 15.3 0.4 0 0.4 0.4 13 5 21 305 83 0 83 0 -6.4 0 -6.2 -6.7 12/06/2004 18:30:00 20.9 2.2 25.6 15.6 20.6 2.2 26 15.6 0.4 0 0.4 0.4 13 6 7 305 84 0 84 0 -6.3 0.1 -6 -6.7 12/06/2004 18:40:00 21.1 1.7 25.6 16.8 21 1.8 25.2 16.1 0.4 0 0.4 0.4 12 5 10 305 84 0 84 0 -6.2 0.1 -6 -6.7 12/06/2004 18:50:00 21.4 2 26.3 16.1 21 1.9 26 16.4 0.4 0 0.4 0.4 16 6 25 305 84 0 84 0 -6.1 0 -5.8 -6.4 12/06/2004 19:00:00 20.7 2.1 25.2 15.6 20.4 2.2 25.2 14.5 0.4 0 0.4 0.4 16 8 21 305 84 0 84 0 -6.2 0 -5.8 -6.7 12/06/2004 19:10:00 20.6 1.9 25.2 14.9 20 1.9 25.2 15.3 0.4 0 0.4 0.4 27 7 34 305 83 0 84 0 -6.1 0 -5.8 -6.4 12/06/2004 19:20:00 22.7 1.7 27.1 17.9 22.1 1.8 26.8 17.2 0.4 0 0.4 0.4 27 5 24 305 83 0 83 0 -6.1 0 -6 -6.2 12/06/2004 19:30:00 21.6 1.9 26.3 16.1 20.9 2 25.6 15.3 0.4 0 0.4 0.4 30 5 32 305 83 0 82 0 -6.1 0 -6 -6.2 12/06/2004 19:40:00 21.9 2 26.8 16.1 21.4 2 26 15.6 0.4 0 0.4 0.4 31 5 26 305 83 0 82 0 -6 0 -5.8 -6.2 12/06/2004 19:50:00 22.2 1.6 26 17.9 21.5 1.7 25.2 16.8 0.4 0 0.4 0.4 31 4 34 305 82 0 82 0 -6.1 0 -5.8 -6.2 12/06/2004 20:00:00 21 1.8 25.2 16.4 20.3 1.9 24.8 15.6 0.4 0 0.4 0.4 30 5 25 305 83 0 82 0 -6.1 0 -5.8 -6.2 12/06/2004 20:10:00 20.4 1.8 24.8 14.5 20.2 2 24.4 14.9 0.4 0 0.4 0.4 24 8 17 305 83 0 83 0 -6.1 0 -5.8 -6.4 12/06/2004 20:20:00 23.4 2.2 27.5 17.2 23.1 2.3 27.9 16.8 0.4 0 0.4 0.4 12 4 10 305 83 0 83 0 -6.5 0.2 -6 -7.1 12/06/2004 20:30:00 22.8 1.7 26.8 16.8 22.4 1.8 26.8 16.4 0.4 0 0.4 0.4 12 5 20 305 83 0 83 0 -6.5 0 -6.2 -6.9 12/06/2004 20:40:00 22.8 2 26.3 17.2 22.5 1.9 26.8 17.9 0.4 0 0.4 0.4 11 5 10 305 83 0 83 0 -6.7 0 -6.7 -6.9 12/06/2004 20:50:00 23 1.7 27.9 17.6 22.7 2 27.9 16.4 0.4 0 0.4 0.4 13 5 11 305 83 0 83 0 -6.9 0.1 -6.7 -7.1 12/06/2004 21:00:00 22.8 1.7 27.1 17.6 22.4 1.7 26.8 17.2 0.4 0 0.4 0.4 14 5 17 305 83 0 82 0 -6.8 0.1 -6.7 -7.1 12/06/2004 21:10:00 22.6 1.9 27.1 16.4 22.2 2 26.3 16.1 0.4 0 0.4 0.4 11 5 12 305 82 0 82 0 -6.9 0.1 -6.7 -7.1 12/06/2004 21:20:00 23.1 1.7 27.1 17.9 22.9 1.7 27.1 17.2 0.4 0 0.4 0.4 12 5 15 305 82 0 82 0 -6.9 0 -6.7 -7.1 12/06/2004 21:30:00 22.6 1.7 26.3 17.6 22.3 1.8 27.1 17.6 0.4 0 0.4 0.4 11 4 8 305 82 0 82 0 -7 0.1 -6.7 -7.3 12/06/2004 21:40:00 21.9 2.1 26.8 16.1 21.7 2.2 27.5 15.3 0.4 0 0.4 0.4 12 5 11 305 82 0 82 0 -7 0.1 -6.7 -7.1 12/06/2004 21:50:00 22 2.2 26.8 16.8 21.7 2.3 26.3 16.1 0.4 0 0.4 0.4 11 5 13 305 82 0 82 0 -6.9 0.1 -6.4 -7.1 12/06/2004 22:00:00 22.3 1.6 26 17.6 22 1.7 26 16.8 0.4 0 0.4 0.4 11 4 11 305 82 0 82 0 -7.1 0 -6.9 -7.3 12/06/2004 22:10:00 22.4 2 26.8 17.2 22 2.2 26.8 16.4 0.4 0 0.4 0.4 11 4 9 305 82 0 82 0 -7 0.1 -6.7 -7.3 12/06/2004 22:20:00 22.6 1.9 26.8 17.6 22.4 2 26.3 17.2 0.4 0 0.4 0.4 11 5 13 305 82 0 82 0 -7.1 0 -6.9 -7.3 12/06/2004 22:30:00 21.8 2 26 16.8 21.5 2.1 25.6 16.4 0.4 0 0.4 0.4 11 5 1 305 82 0 82 0 -7.1 0 -6.9 -7.3 12/06/2004 22:40:00 21.7 2 25.6 15.6 21.4 2.2 26 14.9 0.4 0 0.4 0.4 9 5 6 305 81 0 82 0 -7.2 0 -6.9 -7.3 12/06/2004 22:50:00 22.4 2 26.3 16.8 22.2 2.2 26.3 16.1 0.4 0 0.4 0.4 8 5 9 305 81 0 82 0 -7.2 0 -7.1 -7.5 12/06/2004 23:00:00 21.4 1.8 26 16.1 21.2 1.8 26.3 16.1 0.4 0 0.4 0.4 10 5 10 305 81 0 82 0 -7.1 0 -6.9 -7.3 12/06/2004 23:10:00 22.3 1.8 26.3 16.4 22 1.9 26 17.2 0.4 0 0.4 0.4 9 5 8 305 81 0 82 0 -7.2 0 -7.1 -7.3 12/06/2004 23:20:00 21.8 1.7 26 16.4 21.5 1.9 26.3 16.4 0.4 0 0.4 0.4 10 5 7 305 81 0 81 0 -7.2 0 -6.9 -7.5 12/06/2004 23:30:00 21.9 2 26.3 16.1 21.7 2.1 26.8 16.1 0.4 0 0.4 0.4 9 5 11 305 81 0 82 0 -7.2 0 -7.1 -7.5 12/06/2004 23:40:00 22.8 1.6 26.8 18.3 22.5 1.7 26.8 17.2 0.4 0 0.4 0.4 12 4 14 305 81 0 81 0 -7.3 0 -7.1 -7.5 12/06/2004 23:50:00 22.6 1.7 26 17.2 22.5 1.7 26.3 17.9 0.4 0 0.4 0.4 10 4 4 305 81 0 81 0 -7.3 0 -7.1 -7.5 12/07/2004 00:00:00 21.4 2.1 25.6 15.6 21.1 2.1 25.6 15.6 0.4 0 0.4 0.4 10 5 9 305 81 0 81 0 -7.3 0 -6.9 -7.5 12/07/2004 00:10:00 21.2 2 25.6 15.6 20.8 2.1 25.6 16.1 0.4 0 0.4 0.4 11 5 9 305 81 0 81 0 -7.2 0 -6.9 -7.5 12/07/2004 00:20:00 22.2 1.5 26 16.8 22 1.7 26 17.2 0.4 0 0.4 0.4 7 5 11 305 81 0 81 0 -7.4 0.1 -7.1 -7.7 12/07/2004 00:30:00 21.6 1.7 25.2 17.2 21.2 1.8 25.2 16.4 0.4 0 0.4 0.4 7 5 9 305 81 0 81 0 -7.4 0 -7.1 -7.7 12/07/2004 00:40:00 21.4 1.7 24.8 16.8 20.9 1.8 25.2 15.6 0.4 0 0.4 0.4 7 5 3 305 81 0 81 0 -7.4 0.1 -7.1 -7.7 12/07/2004 00:50:00 22.1 1.5 25.6 17.9 21.8 1.7 25.6 16.8 0.4 0 0.4 0.4 8 5 9 305 81 0 81 0 -7.6 0.1 -7.1 -7.7 12/07/2004 01:00:00 21 1.7 24.4 15.6 20.6 1.7 24.4 16.1 0.4 0 0.4 0.4 8 6 7 305 81 0 81 0 -7.4 0 -7.3 -7.7 12/07/2004 01:10:00 21.4 2 24.8 16.8 21.2 2 25.2 15.6 0.4 0 0.4 0.4 6 5 2 305 81 0 81 0 -7.6 0.1 -7.3 -7.9 12/07/2004 01:20:00 22.2 1.9 25.6 16.8 21.9 1.9 26 16.8 0.4 0 0.4 0.4 7 5 15 305 80 0 80 0 -7.7 0 -7.3 -7.9 12/07/2004 01:30:00 22.1 1.6 26 17.2 21.7 1.7 26.8 17.2 0.4 0 0.4 0.4 7 5 8 305 80 0 80 0 -7.6 0 -7.3 -7.9 12/07/2004 01:40:00 20.9 1.8 24.8 15.3 20.5 1.9 24.8 14.1 0.4 0 0.4 0.4 8 6 2 305 80 0 80 0 -7.6 0.1 -7.3 -7.9 12/07/2004 01:50:00 22.4 1.7 26.3 17.6 21.8 1.7 26.3 17.2 0.4 0 0.4 0.4 8 5 8 305 80 0 80 0 -7.7 0 -7.3 -7.9 12/07/2004 02:00:00 22.5 1.7 26.8 17.2 21.6 1.8 25.6 16.8 0.4 0 0.4 0.4 8 5 10 305 80 0 80 0 -7.7 0 -7.5 -7.9 12/07/2004 02:10:00 22.3 1.8 26 16.8 21.3 1.7 25.6 16.8 0.4 0 0.4 0.4 8 5 9 305 80 0 80 0 -7.8 0 -7.7 -8.2 12/07/2004 02:20:00 22.2 1.9 26 16.1 21.4 1.8 24.8 14.9 0.4 0 0.4 0.4 8 5 13 305 80 0 80 0 -7.7 0 -7.5 -7.9 12/07/2004 02:30:00 22.5 1.8 26.3 16.8 22 1.9 26.3 16.8 0.4 0 0.4 0.4 6 5 2 305 80 0 80 0 -7.7 0 -7.3 -7.9 12/07/2004 02:40:00 22.4 1.9 26.8 16.4 22.1 1.9 26.8 16.4 0.4 0 0.4 0.4 6 5 3 305 80 0 80 0 -7.7 0 -7.5 -8.2 12/07/2004 02:50:00 22.5 1.9 27.5 17.2 22.1 2 26.8 17.2 0.4 0 0.4 0.4 8 5 6 305 80 0 80 0 -7.8 0 -7.7 -7.9 12/07/2004 03:00:00 21.5 1.8 25.6 15.3 21.1 2 26 15.6 0.4 0 0.4 0.4 7 5 7 305 80 0 80 0 -7.7 0 -7.5 -7.9 12/07/2004 03:10:00 22.2 1.7 25.6 17.9 21.7 1.7 25.2 16.8 0.4 0 0.4 0.4 9 4 9 305 80 0 80 0 -7.8 0.1 -7.7 -8.2 12/07/2004 03:20:00 21.3 1.7 25.6 16.8 20.9 1.7 24.8 16.4 0.4 0 0.4 0.4 8 4 11 305 80 0 80 0 -7.8 0 -7.7 -8.2 12/07/2004 03:30:00 21.8 1.7 25.2 17.6 21.3 1.7 25.2 16.8 0.4 0 0.4 0.4 7 5 4 305 80 0 80 0 -7.9 0 -7.7 -8.2 12/07/2004 03:40:00 21.5 1.9 25.6 16.1 21 2 26 15.6 0.4 0 0.4 0.4 9 5 2 305 80 0 80 0 -7.8 0 -7.7 -7.9 12/07/2004 03:50:00 21.8 1.6 25.2 16.8 21.6 1.7 25.6 16.8 0.4 0 0.4 0.4 5 5 3 305 80 0 80 0 -7.9 0.1 -7.7 -8.2 12/07/2004 04:00:00 20.9 1.7 24.8 16.1 20.6 1.9 24 14.9 0.4 0 0.4 0.4 8 5 5 305 80 0 80 0 -7.8 0.1 -7.3 -8.2 12/07/2004 04:10:00 20.7 1.8 25.6 15.6 20.5 1.9 24.8 15.6 0.4 0 0.4 0.4 8 6 18 305 80 0 80 0 -7.8 0 -7.5 -8.2 12/07/2004 04:20:00 21.1 1.8 25.6 17.2 20.9 1.9 25.6 16.8 0.4 0 0.4 0.4 9 6 6 305 80 0 80 0 -7.8 0 -7.5 -8.2 12/07/2004 04:30:00 20.5 1.9 24.8 14.9 20.2 2 24.8 14.9 0.4 0 0.4 0.4 9 5 4 305 80 0 80 0 -7.8 0 -7.5 -7.9 12/07/2004 04:40:00 21.5 2 28.3 16.1 21.3 2.2 27.9 15.3 0.4 0 0.4 0.4 10 5 9 305 80 0 80 0 -7.9 0.1 -7.5 -8.2 12/07/2004 04:50:00 21.2 2.1 25.2 15.6 20.8 2 26 15.6 0.4 0 0.4 0.4 10 6 18 305 80 0 80 0 -7.8 0.1 -7.7 -8.2 12/07/2004 05:00:00 22.2 1.7 26.3 17.2 21.9 1.9 26.8 17.2 0.4 0 0.4 0.4 6 5 1 305 80 0 80 0 -8.2 0 -7.9 -8.4 12/07/2004 05:10:00 22.2 1.4 25.2 18.3 22.1 1.4 25.2 17.6 0.4 0 0.4 0.4 10 5 7 305 80 0 80 0 -8.2 0 -7.9 -8.4 12/07/2004 05:20:00 20.8 2 26 14.9 20.5 2.1 25.2 14.9 0.4 0 0.4 0.4 13 6 18 305 80 0 80 0 -8 0.1 -7.7 -8.2 12/07/2004 05:30:00 21.2 1.9 24.8 16.1 21.1 2 24.8 15.6 0.4 0 0.4 0.4 11 6 16 305 80 0 80 0 -7.9 0.1 -7.7 -8.2 12/07/2004 05:40:00 22.1 1.9 27.1 15.6 21.7 2 26.3 15.3 0.4 0 0.4 0.4 7 5 8 305 80 0 80 0 -8 0.1 -7.7 -8.4 12/07/2004 05:50:00 21.4 2.4 26.3 15.3 21.3 2.5 26.8 14.1 0.4 0 0.4 0.4 8 5 7 305 80 0 80 0 -8.1 0.1 -7.7 -8.4 12/07/2004 06:00:00 21.8 2.1 27.1 16.8 21.5 2.2 26.3 16.8 0.4 0 0.4 0.4 13 4 10 305 80 0 80 0 -8 0.1 -7.7 -8.2 12/07/2004 06:10:00 21.2 1.9 25.2 16.1 20.9 1.9 25.2 15.3 0.4 0 0.4 0.4 11 5 6 305 80 0 80 0 -7.9 0 -7.7 -8.2 12/07/2004 06:20:00 21.5 2.1 26.8 15.3 21.3 2.2 26 16.1 0.4 0 0.4 0.4 9 5 15 305 80 0 80 0 -8 0.1 -7.7 -8.2 12/07/2004 06:30:00 22.6 1.7 26.3 17.2 22.1 1.9 26.3 16.8 0.4 0 0.4 0.4 9 6 5 305 80 0 80 0 -8.2 0 -7.7 -8.4 12/07/2004 06:40:00 21.9 1.8 25.6 16.8 21.4 1.8 25.2 16.1 0.4 0 0.4 0.4 8 6 5 305 80 0 80 0 -8.2 0 -7.9 -8.4 12/07/2004 06:50:00 20.9 2.1 25.6 16.4 20.7 2.2 25.2 16.1 0.4 0 0.4 0.4 10 5 11 305 80 0 80 0 -8.2 0.1 -7.7 -8.4 12/07/2004 07:00:00 21.7 2.1 26.3 14.5 21.5 2.1 26.8 15.6 0.4 0 0.4 0.4 8 5 3 305 80 0 80 0 -8.2 0.1 -7.7 -8.6 12/07/2004 07:10:00 22.9 1.8 26.8 18.3 22.4 1.9 26.8 16.4 0.4 0 0.4 0.4 8 5 11 305 80 0 80 0 -8.3 0 -8.2 -8.4 12/07/2004 07:20:00 22.3 2.1 27.1 16.8 21.9 2.3 27.1 16.1 0.4 0 0.4 0.4 8 5 9 305 80 0 80 0 -8.4 0 -7.9 -8.6 12/07/2004 07:30:00 21.8 1.8 26.3 16.4 21.7 1.9 25.6 16.1 0.4 0 0.4 0.4 8 4 16 305 80 0 80 0 -8.3 0 -8.2 -8.6 12/07/2004 07:40:00 21.4 2 25.2 14.1 21.2 1.9 25.2 14.5 0.4 0 0.4 0.4 10 5 9 305 80 0 80 0 -8.3 0 -7.9 -8.6 12/07/2004 07:50:00 22.3 1.6 26.8 17.6 22.2 1.7 26.8 17.9 0.4 0 0.4 0.4 5 6 359 305 80 0 80 0 -8.3 0 -8.2 -8.6 12/07/2004 08:00:00 21.4 1.6 24.8 17.2 21.3 1.7 25.2 16.8 0.4 0 0.4 0.4 6 6 7 305 80 0 81 0 -8.2 0 -7.9 -8.4 12/07/2004 08:10:00 22 1.6 26 17.6 21.8 1.7 26 17.6 0.4 0 0.4 0.4 6 5 7 305 80 0 80 0 -8.3 0 -7.9 -8.4 12/07/2004 08:20:00 22.1 1.9 26.3 17.6 21.8 1.9 26.3 17.2 0.4 0 0.4 0.4 7 5 9 305 80 0 80 0 -8.3 0 -7.9 -8.6 12/07/2004 08:30:00 20.5 2.2 26.3 15.3 20.5 2.3 26.3 14.5 0.4 0 0.4 0.4 9 5 0 305 80 0 80 0 -8.2 0 -7.9 -8.4 12/07/2004 08:40:00 21.7 1.7 26 17.6 21.5 1.8 25.2 16.4 0.4 0 0.4 0.4 8 6 2 305 80 0 80 0 -8.3 0 -7.9 -8.4 12/07/2004 08:50:00 21.6 1.7 25.6 15.6 21.3 1.7 25.6 16.4 0.4 0 0.4 0.4 8 6 13 305 80 0 80 0 -8.4 0 -7.9 -8.6 12/07/2004 09:00:00 22.7 2.1 27.5 16.8 22.5 2.2 27.9 17.2 0.4 0 0.4 0.4 8 5 7 305 80 0 80 0 -8.4 0 -8.2 -8.6 12/07/2004 09:10:00 22.6 1.9 27.1 17.2 22.4 1.9 26.8 17.6 0.4 0 0.4 0.4 7 5 5 305 80 0 80 0 -8.4 0 -8.2 -8.6 12/07/2004 09:20:00 22.9 1.8 26.3 16.8 22.6 1.8 26.3 16.8 0.4 0 0.4 0.4 8 5 5 305 80 0 80 0 -8.4 0 -8.2 -8.6 12/07/2004 09:30:00 23.3 2 27.1 17.2 23.1 2.1 27.5 16.4 0.4 0 0.4 0.4 8 5 9 305 80 0 80 0 -8.5 0 -8.2 -8.8 12/07/2004 09:40:00 22.5 2.1 26.8 16.1 22.4 2.2 27.1 16.1 0.4 0 0.4 0.4 7 4 8 305 80 0 80 0 -8.4 0 -8.2 -8.6 12/07/2004 09:50:00 23 1.8 27.1 17.2 22.9 1.8 26.8 17.9 0.4 0 0.4 0.4 8 5 8 305 80 0 80 0 -8.4 0 -8.2 -8.6 12/07/2004 10:00:00 22.6 1.9 26.3 17.6 22.4 1.9 27.1 17.2 0.4 0 0.4 0.4 5 5 12 305 80 0 80 0 -8.4 0.1 -8.2 -8.6 12/07/2004 10:10:00 21.3 1.9 26 15.6 21.2 2.1 26 14.1 0.4 0 0.4 0.4 7 5 5 305 80 0 80 0 -8.3 0 -8.2 -8.6 12/07/2004 10:20:00 22.2 1.9 27.5 16.8 22 2 27.9 16.8 0.4 0 0.4 0.4 6 5 7 305 80 0 80 0 -8.2 0 -7.7 -8.4 12/07/2004 10:30:00 21.8 2 26.8 16.1 21.7 2.1 26.8 15.6 0.4 0 0.4 0.4 5 5 5 305 80 0 80 0 -8.2 0 -7.9 -8.4 12/07/2004 10:40:00 21.6 2.1 25.6 15.6 21.5 2.3 26 16.4 0.4 0 0.4 0.4 6 5 9 305 80 0 80 0 -8.1 0 -7.7 -8.4 12/07/2004 10:50:00 22.5 1.7 26.8 17.9 22.4 1.7 27.5 17.6 0.4 0 0.4 0.4 7 5 11 305 80 0 80 0 -8.2 0 -7.9 -8.4 12/07/2004 11:00:00 21.3 2 25.6 13.7 21.3 2 26.3 14.5 0.4 0 0.4 0.4 7 6 11 305 80 0 80 0 -8.2 0 -7.9 -8.4 12/07/2004 11:10:00 21.6 2.1 25.6 16.1 21.3 2.2 25.6 16.1 0.4 0 0.4 0.4 7 6 13 305 80 0 80 0 -8.3 0 -7.9 -8.6 12/07/2004 11:20:00 21.9 1.8 27.1 17.2 21.8 2 27.1 16.8 0.4 0 0.4 0.4 9 5 7 305 80 0 80 0 -8.3 0 -7.9 -8.4 12/07/2004 11:30:00 23 1.7 26.3 16.4 23 1.9 27.1 16.1 0.4 0 0.4 0.4 6 5 2 305 80 0 80 0 -8.3 0 -7.9 -8.4 12/07/2004 11:40:00 22.3 2 26.3 17.2 22.1 2 26.8 16.4 0.4 0 0.4 0.4 9 5 4 305 80 0 80 0 -8.3 0 -7.9 -8.6 12/07/2004 11:50:00 23.2 2.7 27.9 14.9 22.8 2.7 28.3 14.9 0.4 0 0.4 0.4 8 5 11 305 80 0 80 0 -8.2 0 -7.7 -8.4 12/07/2004 12:00:00 22.1 1.9 26 17.9 22 1.9 26 16.8 0.4 0 0.4 0.4 5 4 7 305 80 0 80 0 -8.3 0 -7.9 -8.4 12/07/2004 12:10:00 21.8 2.2 27.1 16.4 21.7 2.2 26.8 16.1 0.4 0 0.4 0.4 9 6 359 305 80 0 81 0 -8.1 0.1 -7.7 -8.4 12/07/2004 12:20:00 22 2 26.8 17.2 21.8 2.2 26.3 16.1 0.4 0 0.4 0.4 8 6 7 305 80 0 80 0 -8.2 0 -7.7 -8.4 12/07/2004 12:30:00 22.5 2 27.5 16.8 22.3 2.1 27.1 16.1 0.4 0 0.4 0.4 8 5 7 305 81 0 81 0 -8.3 0 -8.2 -8.6 12/07/2004 12:40:00 23 2.1 27.5 17.2 22.9 2.2 28.3 17.2 0.4 0 0.4 0.4 6 5 12 305 81 0 81 0 -8.3 0 -8.2 -8.6 12/07/2004 12:50:00 23.1 2 27.5 17.6 23 2.1 27.9 17.6 0.4 0 0.4 0.4 7 6 8 305 81 0 81 0 -8.3 0 -7.9 -8.4 12/07/2004 13:00:00 20.9 2.1 25.2 14.9 21 2.3 26.3 14.9 0.4 0 0.4 0.4 7 6 6 305 81 0 81 0 -8.2 0 -7.9 -8.4 12/07/2004 13:10:00 20.4 2.5 25.6 14.5 20.4 2.5 26.3 14.9 0.4 0 0.4 0.4 2 5 5 305 81 0 81 0 -8.4 0.1 -7.9 -8.8 12/07/2004 13:20:00 22.8 1.9 27.1 17.6 22.6 1.9 27.5 18.3 0.4 0 0.4 0.4 5 5 10 305 81 0 81 0 -8.2 0 -7.9 -8.4 12/07/2004 13:30:00 21.6 2.4 26.3 15.6 21.4 2.5 26.3 16.1 0.4 0 0.4 0.4 8 5 6 305 81 0 81 0 -8.1 0 -7.7 -8.2 12/07/2004 13:40:00 22.8 2 27.5 17.9 22.6 2.1 27.9 16.4 0.4 0 0.4 0.4 9 5 11 305 82 2 85 0 -8.2 0 -7.9 -8.4 12/07/2004 13:50:00 22.1 2.3 26.8 15.6 22.1 2.3 26.8 15.3 0.4 0 0.4 0.4 10 5 11 305 82 2 81 0 -8.2 0 -7.7 -8.4 12/07/2004 14:00:00 22.4 2.5 28.7 15.6 22.2 2.5 27.9 15.3 0.4 0 0.4 0.4 7 5 6 305 81 0 81 0 -8.1 0.1 -7.7 -8.4 12/07/2004 14:10:00 21.6 2.3 26 16.1 21.7 2.4 26.3 14.9 0.4 0 0.4 0.4 6 5 0 305 81 0 81 0 -8.3 0 -7.9 -8.4 12/07/2004 14:20:00 22.2 2.1 26 15.6 22.1 2.2 26.3 14.9 0.4 0 0.4 0.4 4 5 11 305 81 0 81 0 -8.2 0 -7.9 -8.4 12/07/2004 14:30:00 22.1 2.5 26.3 14.9 22 2.5 27.1 16.1 0.4 0 0.4 0.4 6 5 356 305 81 0 81 0 -8.2 0 -7.9 -8.4 12/07/2004 14:40:00 22.4 2.2 28.3 16.4 22.1 2.4 28.3 16.1 0.4 0 0.4 0.4 7 5 6 305 81 0 81 0 -8.3 0 -7.9 -8.4 12/07/2004 14:50:00 22.1 2.7 27.5 14.5 22 2.6 27.9 16.1 0.4 0 0.4 0.4 8 6 8 305 81 0 82 0 -8.2 0 -7.9 -8.4 12/07/2004 15:00:00 22.3 2 27.1 16.4 22.2 2.1 27.1 16.1 0.4 0 0.4 0.4 9 6 14 305 81 0 82 0 -8.3 0 -7.9 -8.6 12/07/2004 15:10:00 22 2.3 26.3 15.3 21.8 2.4 26.8 15.6 0.4 0 0.4 0.4 6 6 16 305 82 0 82 0 -8.3 0 -7.9 -8.4 12/07/2004 15:20:00 23.1 2 26.8 18.3 22.9 2.1 27.5 17.2 0.4 0 0.4 0.4 7 5 3 305 81 0 82 0 -8.3 0 -7.9 -8.6 12/07/2004 15:30:00 22 2 27.1 16.4 22 2.1 26.8 16.8 0.4 0 0.4 0.4 6 6 3 305 81 0 82 0 -8.3 0 -7.9 -8.4 12/07/2004 15:40:00 22.8 1.7 26.3 17.9 22.8 1.8 27.1 18.3 0.4 0 0.4 0.4 6 5 7 305 81 0 82 0 -8.3 0 -7.9 -8.6 12/07/2004 15:50:00 21.5 2.3 26 15.3 21.5 2.4 26.8 16.1 0.4 0 0.4 0.4 6 5 5 305 82 0 82 0 -8.2 0 -7.7 -8.4 12/07/2004 16:00:00 21.6 2.4 26.3 15.6 21.6 2.6 26.8 15.6 0.4 0 0.4 0.4 2 6 0 305 82 0 82 0 -8.4 0.1 -8.2 -8.6 12/07/2004 16:10:00 20.4 2.2 25.6 15.3 20.6 2.2 25.6 15.6 0.4 0 0.4 0.4 4 6 4 305 82 0 82 0 -8.2 0.1 -7.7 -8.6 12/07/2004 16:20:00 21.4 2.1 26.3 16.8 21.2 2.2 26.8 16.1 0.4 0 0.4 0.4 8 6 1 305 83 0 82 0 -8.2 0 -7.7 -8.6 12/07/2004 16:30:00 23 2.1 27.9 16.8 23.1 2.3 28.3 17.6 0.4 0 0.4 0.4 5 5 7 305 83 0 82 0 -8.4 0.1 -8.2 -8.6 12/07/2004 16:40:00 22.4 1.7 26.8 17.2 22.5 1.7 26.8 15.6 0.4 0 0.4 0.4 7 5 12 305 83 0 82 0 -8.4 0.1 -7.9 -8.6 12/07/2004 16:50:00 22 2.1 26.8 16.4 21.9 2.2 27.1 16.1 0.4 0 0.4 0.4 4 6 10 305 83 0 82 0 -8.3 0 -7.9 -8.6 12/07/2004 17:00:00 22.5 2.1 27.9 15.3 22.4 2.2 28.3 16.1 0.4 0 0.4 0.4 4 5 358 305 82 0 82 0 -8.3 0 -8.2 -8.6 12/07/2004 17:10:00 22.2 2 26 16.1 22.5 2.1 26.8 14.9 0.4 0 0.4 0.4 2 6 1 305 82 0 82 0 -8.4 0.1 -7.9 -8.8 12/07/2004 17:20:00 21.8 2.3 26.8 15.6 21.9 2.4 27.1 15.6 0.4 0 0.4 0.4 2 5 1 305 82 0 82 0 -8.5 0.1 -8.2 -8.8 12/07/2004 17:30:00 21.6 2 27.1 15.6 21.7 2 27.5 16.1 0.4 0 0.4 0.4 5 6 11 305 82 0 82 0 -8.3 0 -7.9 -8.6 12/07/2004 17:40:00 21.5 2.1 26.3 16.1 21.5 2.1 26.3 16.1 0.4 0 0.4 0.4 5 6 0 305 82 0 82 0 -8.3 0 -7.9 -8.6 12/07/2004 17:50:00 22.9 1.8 27.1 18.3 22.8 2.1 27.1 17.9 0.4 0 0.4 0.4 5 5 2 305 82 0 82 0 -8.4 0 -8.2 -8.6 12/07/2004 18:00:00 22.8 1.7 27.1 18.3 22.6 1.8 27.1 17.6 0.4 0 0.4 0.4 9 5 11 305 81 0 82 0 -8.4 0 -8.2 -8.6 12/07/2004 18:10:00 20.6 1.9 24.8 14.9 20.8 2.1 25.2 15.6 0.4 0 0.4 0.4 1 9 8 305 81 0 81 0 -8.6 0.5 -7.9 -9.6 12/07/2004 18:20:00 20.1 1.8 24.4 14.1 20.4 1.7 25.2 16.1 0.4 0 0.4 0.4 354 6 350 305 81 0 81 0 -9.4 0.2 -9 -9.6 12/07/2004 18:30:00 19.3 1.9 24 13.7 19.5 2 24 14.5 0.4 0 0.4 0.4 358 7 11 305 83 0 83 0 -9.1 0.1 -8.8 -9.4 12/07/2004 18:40:00 20.2 2 26 16.4 20.5 2 26.3 16.1 0.4 0 0.4 0.4 1 6 6 305 84 0 84 0 -8.8 0.2 -8.4 -9.2 12/07/2004 18:50:00 20.8 1.9 25.2 15.6 20.7 2 24.8 15.3 0.4 0 0.4 0.4 5 6 2 305 83 0 84 0 -8.5 0 -8.2 -8.8 12/07/2004 19:00:00 21.7 1.7 26 16.8 21.6 1.8 25.6 16.4 0.4 0 0.4 0.4 8 6 7 305 83 0 82 0 -8.4 0.1 -8.2 -8.6 12/07/2004 19:10:00 21.8 1.8 26.8 16.1 21.7 1.8 26.3 16.1 0.4 0 0.4 0.4 5 5 355 305 82 0 82 0 -8.4 0 -8.2 -8.8 12/07/2004 19:20:00 21.5 1.7 25.2 16.8 21.5 1.7 25.2 16.8 0.4 0 0.4 0.4 7 6 7 305 82 0 82 0 -8.6 0 -8.2 -8.8 12/07/2004 19:30:00 20.3 1.7 24.4 16.1 20.4 1.7 24.4 14.1 0.4 0 0.4 0.4 359 5 359 305 81 0 82 0 -9.1 0.2 -8.8 -9.6 12/07/2004 19:40:00 20.4 2 24.4 14.1 20.5 2.1 24.8 14.1 0.4 0 0.4 0.4 357 5 0 305 82 0 82 0 -9.5 0 -9.2 -9.8 12/07/2004 19:50:00 20.2 1.9 24.4 16.1 20.1 2 25.6 16.1 0.4 0 0.4 0.4 358 5 358 305 83 0 83 0 -9.4 0 -9 -9.6 12/07/2004 20:00:00 20.3 1.6 24.4 16.1 20.3 1.7 24.8 14.9 0.4 0 0.4 0.4 1 5 7 305 83 0 83 0 -9.5 0.1 -9.2 -9.8 12/07/2004 20:10:00 20.2 1.7 23.7 14.9 20.2 1.7 24.4 14.5 0.4 0 0.4 0.4 358 5 358 305 83 0 83 0 -9.6 0.3 -9 -10.2 12/07/2004 20:20:00 20.5 1.9 25.2 14.5 20.5 2 24.8 14.9 0.4 0 0.4 0.4 356 5 358 305 83 0 83 0 -9.9 0.1 -9.6 -10.2 12/07/2004 20:30:00 20.7 1.9 24.4 16.1 20.8 1.9 25.2 15.3 0.4 0 0.4 0.4 355 5 357 305 83 0 83 0 -10.1 0.1 -9.8 -10.4 12/07/2004 20:40:00 20.8 1.6 24 15.3 20.9 1.7 24.8 16.1 0.4 0 0.4 0.4 358 5 3 305 83 0 83 0 -10.3 0 -10 -10.4 12/07/2004 20:50:00 20.3 1.9 24.8 14.1 20.3 1.9 24.8 14.1 0.4 0 0.4 0.4 355 5 351 305 83 0 83 0 -10.2 0.1 -9.8 -10.4 12/07/2004 21:00:00 19.9 1.7 24.8 15.6 19.9 2 25.2 15.3 0.4 0 0.4 0.4 357 5 356 305 83 0 83 0 -10.2 0.1 -9.8 -10.4 12/07/2004 21:10:00 20.4 1.7 24.8 16.4 20.3 1.7 24.4 16.4 0.4 0 0.4 0.4 356 5 351 305 83 0 83 0 -10.3 0 -10 -10.4 12/07/2004 21:20:00 20.9 1.8 24.8 14.9 20.9 1.8 25.6 15.3 0.4 0 0.4 0.4 357 4 357 305 83 0 83 0 -10.3 0 -10 -10.4 12/07/2004 21:30:00 20.7 1.7 24.4 15.6 20.8 1.8 25.2 16.1 0.4 0 0.4 0.4 358 6 0 305 83 0 83 0 -10.4 0 -10.2 -10.7 12/07/2004 21:40:00 19.7 1.8 23.7 14.1 19.5 2 23.7 14.1 0.4 0 0.4 0.4 356 6 354 305 83 0 83 0 -10.4 0.1 -10 -10.7 12/07/2004 21:50:00 19.7 1.8 23.7 14.9 19.6 1.9 23.3 13.7 0.4 0 0.4 0.4 356 6 352 305 83 0 83 0 -10.3 0.1 -9.8 -10.4 12/07/2004 22:00:00 19.5 2 24 14.1 19.4 2 23.7 13.3 0.4 0 0.4 0.4 357 5 354 305 83 0 83 0 -10.4 0 -10.2 -10.9 12/07/2004 22:10:00 20.5 1.7 25.2 16.4 20.4 1.8 24.8 16.4 0.4 0 0.4 0.4 355 4 355 305 83 0 82 0 -10.7 0.2 -10.4 -11.1 12/07/2004 22:20:00 20 1.5 23.3 16.4 19.9 1.6 23.7 16.1 0.4 0 0.4 0.4 355 5 350 305 82 0 82 0 -10.8 0 -10.4 -11.3 12/07/2004 22:30:00 19.4 1.6 22.9 14.5 19.2 1.7 22.9 14.1 0.4 0 0.4 0.4 356 5 352 305 83 0 82 0 -10.7 0.1 -10.4 -10.9 12/07/2004 22:40:00 20.1 1.7 24 15.3 20 1.7 24 14.9 0.4 0 0.4 0.4 356 5 359 305 82 0 82 0 -10.9 0 -10.7 -11.3 12/07/2004 22:50:00 19.3 1.6 22.9 14.5 19.3 1.7 22.9 13.7 0.4 0 0.4 0.4 357 5 350 305 83 0 82 0 -10.9 0.1 -10.4 -11.3 12/07/2004 23:00:00 19.3 1.9 24 14.5 19.1 2 23.7 14.9 0.4 0 0.4 0.4 356 6 352 305 82 0 82 0 -10.9 0 -10.7 -11.1 12/07/2004 23:10:00 19.6 1.7 23.7 13.7 19.6 1.7 23.7 14.5 0.4 0 0.4 0.4 356 5 354 305 82 0 82 0 -11 0.1 -10.7 -11.3 12/07/2004 23:20:00 20.1 1.7 24 14.9 20.1 1.8 24.4 14.9 0.4 0 0.4 0.4 355 5 352 305 82 0 82 0 -11.1 0 -10.9 -11.3 12/07/2004 23:30:00 20.2 1.7 23.7 14.9 20 1.8 23.7 15.3 0.4 0 0.4 0.4 356 5 356 305 82 0 82 0 -11.1 0.1 -10.9 -11.5 12/07/2004 23:40:00 19.4 1.6 23.3 14.9 19.3 1.7 23.3 13.7 0.4 0 0.4 0.4 358 5 354 305 82 0 82 0 -11.1 0.1 -10.9 -11.5 12/07/2004 23:50:00 19.5 1.8 22.9 15.3 19.4 1.8 23.3 14.9 0.4 0 0.4 0.4 356 5 357 305 83 0 82 0 -11.2 0 -10.9 -11.5 12/08/2004 00:00:00 19.7 1.7 23.7 15.6 19.7 1.7 24 15.6 0.4 0 0.4 0.4 354 5 359 305 82 0 82 0 -11.1 0.1 -10.9 -11.5 12/08/2004 00:10:00 18.8 2 22.6 13.3 18.8 1.9 23.3 14.5 0.4 0 0.4 0.4 356 5 1 305 82 0 82 0 -11.2 0.1 -10.9 -11.5 12/08/2004 00:20:00 19.9 1.7 24 15.6 19.8 1.7 24.4 15.6 0.4 0 0.4 0.4 358 5 348 305 82 0 82 0 -11.3 0.1 -11.1 -11.7 12/08/2004 00:30:00 19.4 1.5 23.3 14.9 19.4 1.7 24 15.3 0.4 0 0.4 0.4 358 5 355 305 82 0 82 0 -11.4 0 -11.3 -11.7 12/08/2004 00:40:00 18.9 1.7 22.9 15.3 18.9 1.7 24 14.5 0.4 0 0.4 0.4 359 5 356 305 82 0 82 0 -11.3 0.1 -11.1 -11.7 12/08/2004 00:50:00 19.4 1.6 22.9 14.5 19.4 1.7 23.3 14.1 0.4 0 0.4 0.4 359 6 357 305 82 0 82 0 -11.4 0 -11.1 -11.7 12/08/2004 01:00:00 18.5 1.8 23.7 13.7 18.6 1.9 24 14.1 0.4 0 0.4 0.4 357 6 355 305 82 0 82 0 -11.4 0 -11.3 -11.7 12/08/2004 01:10:00 18.6 1.6 22.9 14.9 18.6 1.6 22.6 14.9 0.4 0 0.4 0.4 358 6 1 305 82 0 82 0 -11.5 0.1 -11.3 -11.7 12/08/2004 01:20:00 18.8 1.7 22.9 14.1 18.8 1.8 23.3 13.7 0.4 0 0.4 0.4 358 4 359 305 82 0 82 0 -11.5 0 -11.3 -11.9 12/08/2004 01:30:00 17.7 1.5 21.4 13.7 17.7 1.6 21.8 13.7 0.4 0 0.4 0.4 357 5 357 305 82 0 82 0 -11.5 0.1 -11.1 -11.9 12/08/2004 01:40:00 17.7 1.8 22.1 13 17.7 2 22.9 13 0.4 0 0.4 0.4 357 6 355 305 82 0 82 0 -11.4 0.2 -10.9 -11.7 12/08/2004 01:50:00 18 1.4 20.6 12.6 17.9 1.5 21 14.1 0.4 0 0.4 0.4 358 5 4 305 82 0 82 0 -11.5 0 -11.3 -11.7 12/08/2004 02:00:00 17 1.7 21.8 13 17.2 1.7 21.8 13.3 0.4 0 0.4 0.4 354 5 359 305 82 0 82 0 -11.6 0.1 -11.3 -12.1 12/08/2004 02:10:00 18 1.5 21.8 14.1 18.1 1.5 21.4 14.1 0.4 0 0.4 0.4 356 6 0 305 82 0 82 0 -11.5 0 -11.3 -11.9 12/08/2004 02:20:00 18.6 1.5 22.9 14.5 18.7 1.6 23.3 14.1 0.4 0 0.4 0.4 356 6 347 305 82 0 82 0 -11.6 0 -11.5 -11.9 12/08/2004 02:30:00 18.5 1.5 22.1 14.5 18.5 1.5 23.3 14.9 0.4 0 0.4 0.4 355 5 350 305 82 0 82 0 -11.7 0 -11.5 -11.9 12/08/2004 02:40:00 18 1.5 21.8 13.7 18.1 1.7 22.6 13.7 0.4 0 0.4 0.4 354 5 357 305 81 0 82 0 -11.8 0.1 -11.7 -12.1 12/08/2004 02:50:00 18 1.5 22.1 13.3 18 1.5 21.8 14.1 0.4 0 0.4 0.4 354 6 355 305 81 0 82 0 -11.8 0.2 -11.3 -12.1 12/08/2004 03:00:00 17.7 1.8 21.8 13 17.8 1.9 22.1 13 0.4 0 0.4 0.4 355 5 355 305 82 0 82 0 -11.5 0.2 -11.3 -11.9 12/08/2004 03:10:00 17.8 1.7 21.4 13.3 17.9 1.7 21.4 12.2 0.4 0 0.4 0.4 355 5 354 305 82 0 82 0 -11.5 0 -11.3 -11.7 12/08/2004 03:20:00 18 1.5 21.8 13.7 18 1.7 22.1 13.7 0.4 0 0.4 0.4 356 6 351 305 82 0 82 0 -11.6 0.1 -11.3 -12.1 12/08/2004 03:30:00 18.2 1.7 21.8 12.6 18.4 1.7 22.6 13 0.4 0 0.4 0.4 355 5 355 305 81 0 81 0 -11.9 0 -11.7 -12.1 12/08/2004 03:40:00 17.2 1.5 21.4 12.6 17.3 1.6 21.4 13.3 0.4 0 0.4 0.4 355 5 351 305 81 0 80 0 -11.6 0.2 -11.3 -12.1 12/08/2004 03:50:00 16.6 1.6 21.8 13 16.7 1.7 22.1 13 0.4 0 0.4 0.4 355 6 355 305 81 0 82 0 -11.7 0.1 -11.5 -12.1 12/08/2004 04:00:00 17.1 1.7 21.8 13 17.1 1.6 21.4 13 0.4 0 0.4 0.4 354 5 351 305 81 0 82 0 -11.5 0 -11.5 -11.7 12/08/2004 04:10:00 17.8 1.7 22.1 14.1 17.9 1.7 22.9 13.7 0.4 0 0.4 0.4 354 5 355 305 81 0 82 0 -11.8 0 -11.5 -12.1 12/08/2004 04:20:00 17.8 1.7 21.4 12.6 17.8 1.7 21.8 13.7 0.4 0 0.4 0.4 352 5 349 305 81 0 81 0 -11.7 0 -11.5 -12.1 12/08/2004 04:30:00 17.7 1.5 21 13 17.8 1.6 21.4 13.3 0.4 0 0.4 0.4 355 6 357 305 81 0 81 0 -11.7 0.1 -11.5 -12.1 12/08/2004 04:40:00 17.3 1.7 21.8 12.2 17.4 1.7 21.8 12.6 0.4 0 0.4 0.4 353 5 354 305 81 0 81 0 -11.8 0.1 -11.5 -12.1 12/08/2004 04:50:00 17.7 1.4 21.8 13.3 17.9 1.5 22.1 13.7 0.4 0 0.4 0.4 356 6 359 305 81 0 81 0 -11.9 0.1 -11.7 -12.1 12/08/2004 05:00:00 18.3 1.3 21.4 14.5 18.3 1.4 21.8 14.9 0.4 0 0.4 0.4 356 5 354 305 81 0 81 0 -12 0 -11.7 -12.1 12/08/2004 05:10:00 17.5 1.7 21.4 13 17.7 1.8 22.1 13.3 0.4 0 0.4 0.4 353 5 352 305 81 0 81 0 -11.9 0.1 -11.7 -12.3 12/08/2004 05:20:00 17.6 1.4 21.8 13.7 17.8 1.4 22.1 14.5 0.4 0 0.4 0.4 355 6 354 305 81 0 81 0 -12 0 -11.7 -12.3 12/08/2004 05:30:00 17.5 1.6 21.8 13.7 17.6 1.7 21.8 12.6 0.4 0 0.4 0.4 356 5 358 305 81 0 81 0 -12 0.1 -11.7 -12.3 12/08/2004 05:40:00 16.8 1.3 20.6 12.6 17 1.5 20.6 12.2 0.4 0 0.4 0.4 354 5 352 305 81 0 81 0 -11.9 0.1 -11.7 -12.1 12/08/2004 05:50:00 17.2 1.6 21 13.3 17.3 1.6 21.8 13.3 0.4 0 0.4 0.4 356 6 354 305 81 0 81 0 -11.8 0.2 -11.5 -12.1 12/08/2004 06:00:00 18 1.3 20.6 14.5 18.1 1.4 21.4 14.1 0.4 0 0.4 0.4 352 6 358 305 80 0 81 0 -12 0 -11.7 -12.5 12/08/2004 06:10:00 17.5 1.7 21.4 13 17.6 1.7 21.4 13 0.4 0 0.4 0.4 354 5 355 305 80 0 80 0 -12.1 0 -11.7 -12.5 12/08/2004 06:20:00 17.8 1.5 21 14.1 17.9 1.5 21.4 14.1 0.4 0 0.4 0.4 355 5 356 305 80 0 80 0 -12.1 0 -12.1 -12.5 12/08/2004 06:30:00 17.7 1.5 21.4 13.7 17.9 1.5 22.6 13.7 0.4 0 0.4 0.4 353 6 354 305 80 0 80 0 -12.3 0.1 -12.1 -12.5 12/08/2004 06:40:00 17.6 1.7 21 12.2 17.8 1.8 21.8 11.8 0.4 0 0.4 0.4 353 6 1 305 80 0 80 0 -12.3 0.1 -12.1 -12.5 12/08/2004 06:50:00 17.4 1.5 20.6 13 17.6 1.6 21.4 13.3 0.4 0 0.4 0.4 356 7 344 305 80 0 80 0 -12.2 0.1 -12.1 -12.5 12/08/2004 07:00:00 17.9 1.4 21 14.1 18.1 1.5 21.4 13.7 0.4 0 0.4 0.4 353 6 352 305 80 0 80 0 -12.3 0.1 -12.1 -12.5 12/08/2004 07:10:00 17.8 1.5 21 13 17.9 1.6 22.1 13.7 0.4 0 0.4 0.4 353 6 350 305 80 0 80 0 -12.3 0.1 -12.1 -12.7 12/08/2004 07:20:00 17.7 1.6 21.8 13 17.9 1.7 21.4 13 0.4 0 0.4 0.4 356 6 351 305 80 0 80 0 -12.4 0.2 -12.1 -12.7 12/08/2004 07:30:00 17.8 1.7 23.3 12.6 17.9 1.8 24 12.6 0.4 0 0.4 0.4 353 6 346 305 80 0 80 0 -12.5 0.1 -12.1 -12.9 12/08/2004 07:40:00 17.6 1.5 21.8 14.1 17.7 1.6 22.1 13.7 0.4 0 0.4 0.4 353 6 0 305 80 0 80 0 -12.5 0.1 -12.1 -12.9 12/08/2004 07:50:00 17.2 1.5 20.6 13 17.4 1.7 21.8 13 0.4 0 0.4 0.4 351 5 349 305 80 0 80 0 -12.5 0.1 -12.1 -12.9 12/08/2004 08:00:00 17.4 1.5 21 11.8 17.6 1.5 21.4 12.6 0.4 0 0.4 0.4 351 7 344 305 80 0 80 0 -12.6 0 -12.3 -12.9 12/08/2004 08:10:00 17.6 1.4 20.6 13 17.8 1.5 21.8 13.7 0.4 0 0.4 0.4 351 6 0 305 80 0 80 0 -12.5 0 -12.3 -12.7 12/08/2004 08:20:00 17.5 1.4 21 13.7 17.7 1.5 21.8 14.1 0.4 0 0.4 0.4 349 5 352 305 80 0 80 0 -12.6 0 -12.5 -12.9 12/08/2004 08:30:00 18 1.3 20.6 14.5 18.2 1.4 21 14.5 0.4 0 0.4 0.4 350 5 354 305 79 0 79 0 -12.9 0.1 -12.5 -12.9 12/08/2004 08:40:00 17.7 1.4 21.4 13.7 18 1.5 22.6 14.1 0.4 0 0.4 0.4 349 5 0 305 79 0 79 0 -12.9 0.1 -12.5 -13.3 12/08/2004 08:50:00 17.4 1.5 21.4 13.7 17.5 1.5 22.6 13.3 0.4 0 0.4 0.4 350 6 343 305 79 0 79 0 -12.9 0.1 -12.5 -13.1 12/08/2004 09:00:00 17.2 1.5 21 12.6 17.5 1.5 21 13.7 0.4 0 0.4 0.4 349 6 352 305 79 0 79 0 -12.9 0.1 -12.5 -13.1 12/08/2004 09:10:00 17.4 1.8 22.1 11.8 17.6 2 22.1 11.8 0.4 0 0.4 0.4 350 6 347 305 79 0 79 0 -12.9 0.1 -12.5 -13.3 12/08/2004 09:20:00 17.4 1.3 20.6 14.5 17.7 1.4 21 13.3 0.4 0 0.4 0.4 350 5 345 305 79 0 79 0 -13.1 0.1 -12.7 -13.3 12/08/2004 09:30:00 16.8 1.5 20.6 13 16.9 1.6 21.8 12.6 0.4 0 0.4 0.4 353 6 353 305 79 0 79 0 -12.8 0.1 -12.5 -13.1 12/08/2004 09:40:00 17 1.6 21 13 17.3 1.7 21.8 12.2 0.4 0 0.4 0.4 352 6 358 305 79 0 79 0 -12.8 0.1 -12.5 -13.1 12/08/2004 09:50:00 16.8 1.5 21 13.3 17 1.5 21.8 13 0.4 0 0.4 0.4 356 7 353 305 78 0 79 0 -13.1 0 -12.9 -13.3 12/08/2004 10:00:00 16.6 1.6 20.2 12.2 16.9 1.7 20.6 12.6 0.4 0 0.4 0.4 354 6 3 305 78 0 78 0 -13 0 -12.9 -13.1 12/08/2004 10:10:00 16.1 1.3 19.5 13 16.4 1.4 19.9 12.6 0.4 0 0.4 0.4 356 7 350 305 79 0 79 0 -13 0 -12.9 -13.3 12/08/2004 10:20:00 16.1 1.5 19.9 11.8 16.3 1.7 20.2 12.2 0.4 0 0.4 0.4 356 7 1 305 78 0 78 0 -13.1 0 -12.9 -13.3 12/08/2004 10:30:00 16.5 1.3 20.2 13 16.8 1.5 19.9 13 0.4 0 0.4 0.4 355 5 5 305 78 0 79 0 -13.1 0 -12.9 -13.3 12/08/2004 10:40:00 16.5 1.6 20.2 13 16.8 1.7 21 12.6 0.4 0 0.4 0.4 353 5 4 305 78 0 78 0 -13.2 0.1 -12.7 -13.5 12/08/2004 10:50:00 16.8 1.5 20.6 12.6 17.2 1.6 21 12.6 0.4 0 0.4 0.4 353 5 358 305 78 0 78 0 -13 0.2 -12.7 -13.7 12/08/2004 11:00:00 17 1.5 20.2 13.3 17.3 1.6 21 13.3 0.4 0 0.4 0.4 352 6 343 305 78 0 78 0 -13.3 0.1 -13.1 -13.5 12/08/2004 11:10:00 16.6 1.6 20.2 11.5 16.8 1.7 20.2 11.8 0.4 0 0.4 0.4 356 6 359 305 78 0 78 0 -13.4 0.1 -13.1 -13.7 12/08/2004 11:20:00 16.5 1.5 21.4 13 16.6 1.6 22.1 13 0.4 0 0.4 0.4 356 7 357 305 78 0 78 0 -13.1 0.1 -12.9 -13.7 12/08/2004 11:30:00 17.4 1.7 21.8 13.7 17.7 1.7 22.6 13.7 0.4 0 0.4 0.4 354 5 2 305 78 0 78 0 -13.4 0 -13.3 -13.7 12/08/2004 11:40:00 17.3 1.6 20.6 13 17.5 1.7 21.4 13 0.4 0 0.4 0.4 352 5 353 305 78 0 78 0 -13.5 0.1 -13.1 -13.7 12/08/2004 11:50:00 17.7 1.5 20.6 13.3 18 1.6 21.4 13.7 0.4 0 0.4 0.4 351 4 351 305 78 0 78 0 -13.6 0 -13.3 -13.7 12/08/2004 12:00:00 17.4 1.5 21.4 13.3 17.6 1.5 21.8 13 0.4 0 0.4 0.4 353 5 359 305 78 0 78 0 -13.5 0.1 -13.3 -13.7 12/08/2004 12:10:00 17.4 1.7 21 12.6 17.7 1.8 21.4 13 0.4 0 0.4 0.4 353 5 349 305 78 0 78 0 -13.4 0.1 -13.1 -13.7 12/08/2004 12:20:00 16.7 1.4 20.2 13 17.1 1.5 21.4 13.7 0.4 0 0.4 0.4 351 6 350 305 78 0 78 0 -13.3 0 -13.1 -13.5 12/08/2004 12:30:00 16.1 1.7 20.2 11.1 16.3 1.8 21 11.8 0.4 0 0.4 0.4 352 6 350 305 78 0 78 0 -13.2 0 -12.9 -13.5 12/08/2004 12:40:00 16.6 1.5 19.5 12.2 16.9 1.6 20.6 12.6 0.4 0 0.4 0.4 354 6 352 305 78 0 78 0 -13.3 0.1 -12.9 -13.5 12/08/2004 12:50:00 16.4 1.6 20.2 13 16.8 1.7 21 12.6 0.4 0 0.4 0.4 354 6 338 305 78 0 78 0 -13.4 0.2 -13.1 -13.7 12/08/2004 13:00:00 16 1.5 19.5 12.6 16.3 1.6 19.5 12.2 0.4 0 0.4 0.4 353 6 359 305 78 0 78 0 -13.5 0.1 -13.3 -13.7 12/08/2004 13:10:00 16 1.5 19.9 12.2 16.2 1.5 20.6 12.2 0.4 0 0.4 0.4 354 6 358 305 78 0 78 0 -13.5 0.1 -13.1 -13.7 12/08/2004 13:20:00 16.2 1.5 19.9 11.8 16.5 1.7 20.6 12.2 0.4 0 0.4 0.4 353 6 352 305 78 0 78 0 -13.4 0.1 -12.9 -13.7 12/08/2004 13:30:00 15.6 1.5 19.1 11.8 15.8 1.7 19.5 12.2 0.4 0 0.4 0.4 353 7 344 305 78 0 78 0 -13.5 0.1 -13.3 -13.7 12/08/2004 13:40:00 16.3 1.5 19.5 13 16.6 1.5 20.6 12.6 0.4 0 0.4 0.4 350 5 344 305 77 0 78 0 -13.6 0 -13.5 -13.7 12/08/2004 13:50:00 16.6 1.4 20.2 12.6 17 1.4 21 13.7 0.4 0 0.4 0.4 351 5 355 305 78 0 78 0 -13.6 0 -13.3 -13.7 12/08/2004 14:00:00 16.3 1.5 19.5 13 16.6 1.6 20.2 11.8 0.4 0 0.4 0.4 353 7 355 305 78 0 78 0 -13.5 0.1 -13.1 -13.7 12/08/2004 14:10:00 17.1 1.6 20.2 11.8 17.5 1.7 21.4 12.6 0.4 0 0.4 0.4 349 4 350 305 77 0 77 0 -13.8 0 -13.7 -13.9 12/08/2004 14:20:00 16 1.5 20.6 12.6 16.3 1.5 21 12.6 0.4 0 0.4 0.4 350 5 349 305 78 0 78 0 -13.5 0.1 -13.1 -13.9 12/08/2004 14:30:00 16.1 1.3 19.1 13.3 16.5 1.3 19.9 13 0.4 0 0.4 0.4 354 5 354 305 78 0 78 0 -13.5 0.1 -13.1 -13.7 12/08/2004 14:40:00 16.6 1.5 19.9 12.6 16.8 1.6 20.2 12.6 0.4 0 0.4 0.4 356 5 349 305 78 0 78 0 -13.4 0 -13.1 -13.5 12/08/2004 14:50:00 16.7 1.2 20.6 13 16.9 1.3 21 12.6 0.4 0 0.4 0.4 355 5 358 305 78 0 78 0 -13.4 0.1 -13.1 -13.7 12/08/2004 15:00:00 16.8 1.5 20.6 12.2 17.1 1.5 20.6 12.2 0.4 0 0.4 0.4 357 6 354 305 78 0 78 0 -13.5 0.1 -13.1 -13.9 12/08/2004 15:10:00 16.7 1.7 20.6 12.6 16.9 1.7 21 12.6 0.4 0 0.4 0.4 356 6 358 305 78 0 78 0 -13.7 0 -13.5 -13.9 12/08/2004 15:20:00 15.5 1.4 19.1 11.5 15.8 1.5 19.9 11.8 0.4 0 0.4 0.4 356 8 4 305 78 0 78 0 -13.6 0 -13.3 -13.7 12/08/2004 15:30:00 15.6 1.5 19.5 11.5 15.8 1.7 19.9 11.1 0.4 0 0.4 0.4 354 6 353 305 78 0 78 0 -13.4 0 -13.3 -13.7 12/08/2004 15:40:00 15.5 1.5 20.2 11.5 15.9 1.5 20.2 12.2 0.4 0 0.4 0.4 350 7 351 305 78 0 78 0 -13.5 0.1 -13.1 -13.7 12/08/2004 15:50:00 15.7 1.5 18.7 11.5 16 1.5 19.9 11.8 0.4 0 0.4 0.4 355 7 1 305 78 0 78 0 -13.4 0.1 -13.1 -13.7 12/08/2004 16:00:00 15.7 1.3 19.1 11.8 16 1.4 19.5 12.6 0.4 0 0.4 0.4 357 6 355 305 78 0 78 0 -13.5 0.1 -13.1 -13.7 12/08/2004 16:10:00 16.3 1.6 19.9 12.2 16.6 1.7 20.6 12.2 0.4 0 0.4 0.4 354 5 355 305 78 0 78 0 -13.6 0.1 -13.3 -13.9 12/08/2004 16:20:00 15.8 1.3 19.1 12.2 16.2 1.3 19.5 13 0.4 0 0.4 0.4 355 5 350 305 78 0 77 0 -13.6 0 -13.3 -13.7 12/08/2004 16:30:00 16.2 1.5 20.2 12.6 16.6 1.6 20.6 13 0.4 0 0.4 0.4 353 6 358 305 78 0 78 0 -13.6 0 -13.3 -13.7 12/08/2004 16:40:00 15.3 1.2 19.1 12.6 15.8 1.3 18.7 12.2 0.4 0 0.4 0.4 351 6 348 305 78 0 78 0 -13.5 0.1 -13.1 -13.7 12/08/2004 16:50:00 16.1 1.3 19.5 13 16.5 1.5 19.9 12.2 0.4 0 0.4 0.4 348 5 339 305 78 0 78 0 -13.5 0.1 -13.1 -13.7 12/08/2004 17:00:00 15.4 1.6 19.1 11.5 15.9 1.6 19.9 12.6 0.4 0 0.4 0.4 353 6 354 305 78 0 78 0 -13.5 0.1 -13.1 -13.7 12/08/2004 17:10:00 15.9 1.2 18.3 12.6 16.2 1.3 19.5 12.6 0.4 0 0.4 0.4 352 6 351 305 78 0 78 0 -13.3 0 -13.1 -13.7 12/08/2004 17:20:00 16.3 1 18.7 13.7 16.6 1.2 19.9 13.3 0.4 0 0.4 0.4 350 6 344 305 78 0 78 0 -13.5 0 -13.3 -13.7 12/08/2004 17:30:00 15.7 1.7 19.9 12.2 16.1 1.8 20.2 11.8 0.4 0 0.4 0.4 352 6 350 305 78 0 79 0 -13.3 0.1 -12.9 -13.7 12/08/2004 17:40:00 16.1 1.5 19.9 12.6 16.4 1.5 19.9 13 0.4 0 0.4 0.4 354 6 348 305 78 0 78 0 -13.4 0 -13.3 -13.7 12/08/2004 17:50:00 15.2 1.4 18.3 12.2 15.5 1.4 19.5 12.2 0.4 0 0.4 0.4 354 6 347 305 78 0 78 0 -13.3 0.2 -12.9 -13.7 12/08/2004 18:00:00 15.8 1.6 19.9 12.2 16 1.6 19.9 11.8 0.4 0 0.4 0.4 354 6 354 305 78 0 78 0 -13.3 0.1 -13.1 -13.5 12/08/2004 18:10:00 15.9 1.3 19.5 13 16.2 1.5 20.2 12.2 0.4 0 0.4 0.4 355 7 358 305 78 0 79 0 -13.4 0 -13.1 -13.5 12/08/2004 18:20:00 15.6 1.3 18.7 12.6 16 1.3 19.1 13 0.4 0 0.4 0.4 355 6 358 305 79 0 79 0 -13.2 0.1 -12.9 -13.5 12/08/2004 18:30:00 14.8 1.5 18.3 10.7 15 1.5 19.5 11.5 0.4 0 0.4 0.4 356 7 351 305 79 0 78 0 -12.9 0.1 -12.5 -13.3 12/08/2004 18:40:00 15.1 1.5 17.9 11.1 15.4 1.6 19.1 11.1 0.4 0 0.4 0.4 353 6 358 305 79 0 79 0 -13 0.1 -12.7 -13.3 12/08/2004 18:50:00 15.6 1.5 19.1 11.5 16 1.6 19.5 11.5 0.4 0 0.4 0.4 352 6 357 305 79 0 79 0 -13.1 0.1 -12.9 -13.5 12/08/2004 19:00:00 15.5 1.3 18.3 12.2 15.8 1.3 18.7 12.6 0.4 0 0.4 0.4 351 5 359 305 79 0 79 0 -13.3 0 -13.1 -13.5 12/08/2004 19:10:00 15.7 1.3 20.2 12.6 16.1 1.3 19.9 13 0.4 0 0.4 0.4 351 5 359 305 79 0 79 0 -13.3 0.1 -12.9 -13.5 12/08/2004 19:20:00 15.1 1.2 17.9 11.5 15.5 1.3 17.9 11.5 0.4 0 0.4 0.4 351 5 355 305 79 0 79 0 -13.2 0 -12.9 -13.3 12/08/2004 19:30:00 15.2 1.5 19.5 11.5 15.6 1.5 19.5 12.6 0.4 0 0.4 0.4 352 6 353 305 79 0 79 0 -13.2 0 -12.9 -13.5 12/08/2004 19:40:00 15.9 1.3 18.7 12.6 16.3 1.4 19.9 13 0.4 0 0.4 0.4 352 6 350 305 79 0 79 0 -13.1 0 -12.9 -13.3 12/08/2004 19:50:00 15.6 1.4 18.7 11.1 16 1.5 19.5 11.8 0.4 0 0.4 0.4 349 6 346 305 79 0 79 0 -13.2 0 -12.9 -13.5 12/08/2004 20:00:00 15 1 17.6 11.5 15.4 1.2 17.9 11.1 0.4 0 0.4 0.4 351 7 0 305 79 0 79 0 -13.1 0.1 -12.9 -13.3 12/08/2004 20:10:00 15.3 1.3 19.5 11.8 15.7 1.3 19.9 11.8 0.4 0 0.4 0.4 354 6 354 305 79 0 79 0 -13.1 0 -12.9 -13.3 12/08/2004 20:20:00 15.5 1.3 17.9 11.8 15.9 1.4 19.1 12.2 0.4 0 0.4 0.4 351 6 356 305 79 0 79 0 -13.2 0 -12.9 -13.5 12/08/2004 20:30:00 15.6 1.1 18.3 12.6 16.1 1.2 19.1 12.6 0.4 0 0.4 0.4 354 6 358 305 79 0 79 0 -13.4 0.1 -13.1 -13.7 12/08/2004 20:40:00 15 1.2 18.3 11.8 15.4 1.3 18.7 11.8 0.4 0 0.4 0.4 351 6 352 305 79 0 79 0 -13.3 0.1 -12.9 -13.7 12/08/2004 20:50:00 15.3 1.2 17.9 12.2 15.7 1.3 18.7 11.8 0.4 0 0.4 0.4 353 5 345 305 79 0 79 0 -13.5 0.1 -13.3 -13.7 12/08/2004 21:00:00 15.3 1.2 17.9 11.8 15.6 1.3 18.3 11.8 0.4 0 0.4 0.4 353 5 352 305 79 0 79 0 -13.4 0.1 -13.1 -13.7 12/08/2004 21:10:00 15.3 1.3 18.7 11.5 15.6 1.4 19.5 12.6 0.4 0 0.4 0.4 353 6 354 305 79 0 79 0 -13.4 0 -13.3 -13.7 12/08/2004 21:20:00 15.3 1.3 17.9 12.2 15.7 1.4 19.5 12.2 0.4 0 0.4 0.4 356 6 350 305 79 0 79 0 -13.5 0 -13.3 -13.7 12/08/2004 21:30:00 15.3 1.2 18.3 12.2 15.9 1.3 19.1 12.2 0.4 0 0.4 0.4 352 5 347 305 79 0 79 0 -13.6 0 -13.3 -13.7 12/08/2004 21:40:00 15.4 1.3 18.3 11.8 15.8 1.5 19.5 11.8 0.4 0 0.4 0.4 354 5 348 305 79 0 79 0 -13.5 0 -13.3 -13.7 12/08/2004 21:50:00 16.3 1.3 19.5 13.3 16.6 1.3 20.2 13.3 0.4 0 0.4 0.4 353 4 353 305 79 0 79 0 -13.5 0.1 -13.3 -13.7 12/08/2004 22:00:00 15.9 1.3 19.1 11.5 16.3 1.4 19.9 11.8 0.4 0 0.4 0.4 355 5 351 305 78 0 78 0 -13.6 0 -13.3 -13.7 12/08/2004 22:10:00 16.2 1.2 19.9 12.2 16.5 1.3 19.9 13 0.4 0 0.4 0.4 353 6 354 305 78 0 78 0 -13.6 0 -13.3 -13.7 12/08/2004 22:20:00 16 1.4 19.5 12.2 16.4 1.4 19.5 12.2 0.4 0 0.4 0.4 355 6 357 305 79 0 79 0 -13.6 0 -13.3 -13.7 12/08/2004 22:30:00 15.7 1.2 18.7 11.8 16.2 1.3 19.1 12.2 0.4 0 0.4 0.4 350 5 355 305 79 0 79 0 -13.6 0 -13.3 -13.7 12/08/2004 22:40:00 16.6 1.1 19.5 13 17 1.3 20.2 13.3 0.4 0 0.4 0.4 353 6 358 305 78 0 79 0 -13.7 0.1 -13.3 -14.1 12/08/2004 22:50:00 16.2 1.5 19.9 12.6 16.5 1.6 20.6 13 0.4 0 0.4 0.4 353 5 351 305 78 0 79 0 -13.6 0.1 -13.3 -13.9 12/08/2004 23:00:00 16 1.4 19.5 12.2 16.4 1.5 19.9 11.8 0.4 0 0.4 0.4 353 6 348 305 79 0 78 0 -13.5 0.1 -13.1 -13.7 12/08/2004 23:10:00 16.2 1.1 18.7 13 16.6 1.2 19.9 13.3 0.4 0 0.4 0.4 353 5 352 305 78 0 78 0 -13.6 0 -13.3 -13.7 12/08/2004 23:20:00 15.6 1.2 19.1 12.2 15.9 1.3 20.2 12.2 0.4 0 0.4 0.4 351 6 346 305 79 0 79 0 -13.5 0.1 -13.3 -13.7 12/08/2004 23:30:00 16 1.2 19.1 13 16.4 1.4 19.9 11.8 0.4 0 0.4 0.4 351 6 347 305 79 0 79 0 -13.4 0 -13.1 -13.7 12/08/2004 23:40:00 15.7 1.4 20.2 12.6 16 1.5 21 13 0.4 0 0.4 0.4 355 6 351 305 79 0 79 0 -13.3 0.1 -12.9 -13.7 12/08/2004 23:50:00 15.7 1.4 19.5 10.3 16.1 1.5 19.5 11.8 0.4 0 0.4 0.4 353 6 355 305 79 0 79 0 -13.3 0 -12.9 -13.5 12/09/2004 00:00:00 16.2 1.2 19.5 12.6 16.6 1.3 19.5 13.3 0.4 0 0.4 0.4 352 5 359 305 79 0 79 0 -13.3 0 -12.9 -13.5 12/09/2004 00:10:00 15.4 1.3 18.7 11.8 15.7 1.3 18.7 12.2 0.4 0 0.4 0.4 352 6 348 305 79 0 79 0 -13.2 0 -12.9 -13.5 12/09/2004 00:20:00 15.9 1.1 18.7 13 16.2 1.2 19.1 13 0.4 0 0.4 0.4 352 6 355 305 79 0 79 0 -13.2 0.1 -12.9 -13.5 12/09/2004 00:30:00 16.5 1.2 20.2 13.3 16.8 1.3 20.2 12.6 0.4 0 0.4 0.4 357 5 2 305 79 0 79 0 -13.2 0 -13.1 -13.3 12/09/2004 00:40:00 15.9 1.5 19.1 12.2 16.2 1.5 20.2 12.2 0.4 0 0.4 0.4 355 5 355 305 79 0 79 0 -13.2 0.1 -12.9 -13.5 12/09/2004 00:50:00 15.8 1.3 19.9 12.6 16.1 1.4 20.2 13 0.4 0 0.4 0.4 353 6 351 305 79 0 79 0 -13.1 0 -12.9 -13.3 12/09/2004 01:00:00 15.9 1.3 19.1 11.1 16.3 1.4 19.5 12.2 0.4 0 0.4 0.4 351 5 351 305 79 0 79 0 -13.1 0 -12.9 -13.3 12/09/2004 01:10:00 16 1.2 18.7 12.2 16.3 1.4 19.5 12.6 0.4 0 0.4 0.4 350 5 350 305 79 0 79 0 -13.2 0 -12.9 -13.5 12/09/2004 01:20:00 15.7 1.4 19.1 12.2 16.2 1.5 19.9 12.6 0.4 0 0.4 0.4 353 6 3 305 79 0 79 0 -13.2 0 -12.9 -13.5 12/09/2004 01:30:00 16 1.2 18.7 12.2 16.3 1.3 19.5 12.2 0.4 0 0.4 0.4 355 6 352 305 79 0 79 0 -13.1 0.1 -12.9 -13.5 12/09/2004 01:40:00 16.1 1.4 19.5 12.2 16.4 1.6 19.9 12.6 0.4 0 0.4 0.4 355 5 348 305 79 0 79 0 -13.1 0 -12.9 -13.3 12/09/2004 01:50:00 16 1.5 19.9 13 16.3 1.6 20.6 13 0.4 0 0.4 0.4 354 6 350 305 79 0 79 0 -13 0.1 -12.5 -13.3 12/09/2004 02:00:00 15.5 1.2 18.3 12.2 15.8 1.2 19.1 12.6 0.4 0 0.4 0.4 356 5 348 305 79 0 79 0 -12.7 0.1 -12.5 -13.1 12/09/2004 02:10:00 15.9 1.5 19.1 11.5 16.2 1.5 19.9 11.5 0.4 0 0.4 0.4 357 5 0 305 79 0 79 0 -12.8 0.1 -12.5 -13.1 12/09/2004 02:20:00 15.6 1.2 19.9 12.6 15.8 1.3 19.9 12.2 0.4 0 0.4 0.4 357 5 3 305 79 0 79 0 -12.8 0 -12.5 -13.1 12/09/2004 02:30:00 16.5 1.1 19.5 13.3 16.8 1.3 19.9 13.7 0.4 0 0.4 0.4 357 5 353 305 79 0 79 0 -12.9 0.1 -12.5 -13.1 12/09/2004 02:40:00 16.8 1.5 19.9 11.8 17 1.5 20.2 12.2 0.4 0 0.4 0.4 359 5 359 305 79 0 79 0 -13 0 -12.7 -13.3 12/09/2004 02:50:00 16.7 1.8 21 12.6 16.9 1.8 21 12.2 0.4 0 0.4 0.4 359 5 0 305 79 0 79 0 -12.9 0.1 -12.5 -13.1 12/09/2004 03:00:00 17.1 1.4 20.6 13.7 17.3 1.5 21.4 13.7 0.4 0 0.4 0.4 356 5 350 305 79 0 79 0 -13 0 -12.9 -13.3 12/09/2004 03:10:00 16.9 1.5 19.9 13 17.3 1.5 20.6 13 0.4 0 0.4 0.4 357 5 358 305 79 0 79 0 -13 0.1 -12.5 -13.3 12/09/2004 03:20:00 16.4 1.3 20.6 13.3 16.8 1.2 20.2 14.1 0.4 0 0.4 0.4 352 5 353 305 79 0 79 0 -13 0.1 -12.7 -13.1 12/09/2004 03:30:00 16.4 1 19.9 13.3 16.6 1.1 19.5 13.7 0.4 0 0.4 0.4 357 6 358 305 79 0 79 0 -12.9 0.1 -12.5 -13.3 12/09/2004 03:40:00 16.8 1.4 20.6 13.7 17 1.5 20.6 12.6 0.4 0 0.4 0.4 0 5 4 305 79 0 79 0 -12.9 0.1 -12.5 -13.1 12/09/2004 03:50:00 17 1.1 19.9 12.6 17.3 1.1 20.2 13.3 0.4 0 0.4 0.4 357 5 18 305 79 0 79 0 -12.9 0.1 -12.5 -13.1 12/09/2004 04:00:00 16.7 1.3 20.2 13 16.9 1.3 20.6 13 0.4 0 0.4 0.4 357 5 349 305 79 0 79 0 -12.7 0 -12.5 -12.9 12/09/2004 04:10:00 16.5 1.5 20.2 12.6 16.8 1.5 20.2 12.2 0.4 0 0.4 0.4 357 4 3 305 79 0 79 0 -12.7 0 -12.5 -12.9 12/09/2004 04:20:00 17.2 1.2 20.6 14.1 17.4 1.3 20.6 14.1 0.4 0 0.4 0.4 0 5 4 305 79 0 79 0 -12.6 0 -12.3 -12.9 12/09/2004 04:30:00 17.2 1.3 20.2 13.3 17.3 1.5 20.2 13.3 0.4 0 0.4 0.4 359 5 13 305 79 0 79 0 -12.6 0 -12.5 -12.9 12/09/2004 04:40:00 16.7 1.3 19.9 13.3 16.9 1.3 20.2 13 0.4 0 0.4 0.4 0 4 6 305 79 0 80 0 -12.6 0 -12.3 -12.7 12/09/2004 04:50:00 17.2 1.1 20.2 13.7 17.4 1.3 21 13.7 0.4 0 0.4 0.4 0 5 358 305 79 0 79 0 -12.6 0 -12.3 -12.9 12/09/2004 05:00:00 16.6 1.3 19.9 13.3 16.8 1.3 20.2 13 0.4 0 0.4 0.4 2 6 9 305 79 0 79 0 -12.5 0 -12.1 -12.7 12/09/2004 05:10:00 17 1.4 20.6 12.6 17 1.5 20.6 13 0.4 0 0.4 0.4 5 6 7 305 79 0 79 0 -12.4 0.1 -12.1 -12.5 12/09/2004 05:20:00 17.1 1.7 21 13 17.2 1.7 21.8 13 0.4 0 0.4 0.4 2 6 5 305 80 0 80 0 -12.4 0 -12.1 -12.5 12/09/2004 05:30:00 16.6 1.6 19.9 12.2 16.7 1.7 20.6 12.6 0.4 0 0.4 0.4 1 5 1 305 80 0 80 0 -12.3 0.1 -12.1 -12.7 12/09/2004 05:40:00 17.1 1.5 20.2 12.6 17.2 1.5 22.1 13 0.4 0 0.4 0.4 2 5 2 305 80 0 80 0 -12.3 0.2 -12.1 -12.7 12/09/2004 05:50:00 17.7 1.2 20.6 14.9 17.9 1.4 21 14.5 0.4 0 0.4 0.4 0 4 0 305 80 0 80 0 -12.2 0.1 -11.9 -12.5 12/09/2004 06:00:00 17 1.2 20.2 13.7 17.1 1.3 20.2 13.7 0.4 0 0.4 0.4 0 5 357 305 80 0 80 0 -12.4 0 -12.1 -12.7 12/09/2004 06:10:00 17.4 1.3 21.8 14.1 17.6 1.4 21.4 14.5 0.4 0 0.4 0.4 0 6 8 305 80 0 80 0 -12.5 0 -12.1 -12.7 12/09/2004 06:20:00 17.3 1.3 20.6 13.7 17.7 1.5 21.4 14.1 0.4 0 0.4 0.4 356 5 356 305 79 0 80 0 -12.6 0 -12.3 -12.9 12/09/2004 06:30:00 16.7 1.3 20.2 13 17 1.3 20.2 13.3 0.4 0 0.4 0.4 358 4 357 305 80 0 80 0 -12.4 0.1 -12.1 -12.5 12/09/2004 06:40:00 16.7 1.5 19.9 12.2 16.9 1.5 21 13 0.4 0 0.4 0.4 0 6 358 305 80 0 80 0 -12.4 0.1 -12.1 -12.5 12/09/2004 06:50:00 16.5 1.3 20.2 11.5 16.7 1.5 20.6 11.1 0.4 0 0.4 0.4 358 5 0 305 80 0 80 0 -12.4 0.1 -12.1 -12.7 12/09/2004 07:00:00 17.3 1.4 20.6 14.1 17.5 1.6 20.6 13.7 0.4 0 0.4 0.4 358 5 358 305 80 0 80 0 -12.5 0.1 -11.9 -12.7 12/09/2004 07:10:00 17.7 1.5 21.4 13.3 17.8 1.6 22.1 14.5 0.4 0 0.4 0.4 359 4 4 305 80 0 80 0 -12.4 0.1 -12.1 -12.7 12/09/2004 07:20:00 17.9 1.1 20.2 13.7 18.1 1.2 21 12.6 0.4 0 0.4 0.4 356 4 357 305 80 0 80 0 -12.3 0 -12.1 -12.5 12/09/2004 07:30:00 17.2 1.2 20.2 13 17.4 1.5 20.6 12.6 0.4 0 0.4 0.4 359 5 353 305 80 0 80 0 -12.3 0.1 -11.9 -12.5 12/09/2004 07:40:00 17.6 1.7 21 13 17.8 1.7 21 13.3 0.4 0 0.4 0.4 2 6 10 305 80 0 80 0 -12.2 0.2 -11.7 -12.5 12/09/2004 07:50:00 18.1 1.2 20.6 14.1 18.1 1.2 22.1 14.1 0.4 0 0.4 0.4 5 4 5 305 80 0 80 0 -12.2 0.1 -11.9 -12.5 12/09/2004 08:00:00 18.2 1.3 21 14.5 18.2 1.4 21.4 14.5 0.4 0 0.4 0.4 3 5 355 305 80 0 80 0 -12.2 0.1 -12.1 -12.5 12/09/2004 08:10:00 17.8 1.5 21 13 17.9 1.5 21.4 13.7 0.4 0 0.4 0.4 0 5 1 305 80 0 80 0 -12.2 0.1 -11.7 -12.5 12/09/2004 08:20:00 17.8 1.5 22.1 14.1 18 1.5 21.8 14.5 0.4 0 0.4 0.4 359 5 2 305 80 0 80 0 -12.4 0.1 -12.1 -12.7 12/09/2004 08:30:00 17.6 1.3 21 13.7 17.8 1.3 21.8 13.3 0.4 0 0.4 0.4 359 6 8 305 80 0 79 0 -12.3 0.1 -12.1 -12.5 12/09/2004 08:40:00 18.5 1.6 22.1 13.7 18.7 1.6 22.6 14.9 0.4 0 0.4 0.4 2 5 0 305 80 0 80 0 -12.3 0.1 -12.1 -12.5 12/09/2004 08:50:00 17.2 1.6 22.1 13 17.2 1.6 22.9 13.3 0.4 0 0.4 0.4 3 5 359 305 80 0 80 0 -12.1 0.1 -11.9 -12.5 12/09/2004 09:00:00 18 1.5 21.4 14.5 18.2 1.5 21.4 13.7 0.4 0 0.4 0.4 1 5 2 305 79 0 80 0 -12.4 0.1 -12.1 -12.5 12/09/2004 09:10:00 17.9 1.3 20.6 13.7 18.1 1.5 21.8 13 0.4 0 0.4 0.4 359 5 15 305 79 0 79 0 -12.3 0.1 -11.9 -12.5 12/09/2004 09:20:00 17.2 1.7 20.6 12.6 17.3 1.7 21 12.6 0.4 0 0.4 0.4 1 5 359 305 80 0 80 0 -12.2 0.1 -11.7 -12.5 12/09/2004 09:30:00 17.8 1.3 21.8 13.7 18.1 1.3 22.1 13.7 0.4 0 0.4 0.4 0 5 358 305 80 0 80 0 -12.2 0.1 -11.7 -12.5 12/09/2004 09:40:00 17.4 1.5 20.6 12.6 17.6 1.5 20.6 12.6 0.4 0 0.4 0.4 359 5 2 305 80 0 80 0 -12.1 0 -11.9 -12.5 12/09/2004 09:50:00 17.3 1.1 20.2 14.5 17.4 1.2 21.4 13.7 0.4 0 0.4 0.4 2 6 356 305 80 0 80 0 -12.1 0 -11.9 -12.3 12/09/2004 10:00:00 17.1 1.5 21 11.8 17.2 1.7 20.6 11.8 0.4 0 0.4 0.4 2 6 352 305 80 0 80 0 -12 0 -11.7 -12.3 12/09/2004 10:10:00 16.7 1.5 19.9 13 16.9 1.4 20.2 13 0.4 0 0.4 0.4 2 5 358 305 80 0 80 0 -12 0 -11.7 -12.3 12/09/2004 10:20:00 16.8 1.2 19.5 13.3 16.9 1.3 19.9 13.7 0.4 0 0.4 0.4 1 5 357 305 80 0 80 0 -11.9 0.1 -11.5 -12.3 12/09/2004 10:30:00 17.3 1.7 20.6 13.3 17.4 1.8 21 13 0.4 0 0.4 0.4 1 5 4 305 80 0 80 0 -11.9 0 -11.7 -12.1 12/09/2004 10:40:00 17.5 1.5 21.8 12.2 17.7 1.7 21.8 13 0.4 0 0.4 0.4 1 6 358 305 80 0 80 0 -11.9 0.1 -11.5 -12.3 12/09/2004 10:50:00 17.2 1.5 21 13 17.3 1.6 21 13 0.4 0 0.4 0.4 0 5 357 305 80 0 80 0 -11.9 0 -11.7 -12.1 12/09/2004 11:00:00 17.4 1.6 21.4 12.2 17.5 1.7 22.1 12.2 0.4 0 0.4 0.4 0 5 359 305 80 0 80 0 -11.8 0 -11.5 -12.1 12/09/2004 11:10:00 17.9 1.5 21.8 12.2 17.9 1.6 21.4 13 0.4 0 0.4 0.4 3 6 12 305 80 0 80 0 -11.6 0 -11.3 -11.7 12/09/2004 11:20:00 17 1.5 20.6 13.3 17.2 1.6 21 13.3 0.4 0 0.4 0.4 0 5 358 305 80 0 81 0 -11.7 0.1 -11.3 -12.1 12/09/2004 11:30:00 17.4 1.5 20.2 12.2 17.6 1.6 21 12.2 0.4 0 0.4 0.4 357 6 358 305 81 0 81 0 -11.7 0.1 -11.5 -12.1 12/09/2004 11:40:00 17.2 1.4 21 13.3 17.4 1.5 21.8 13.3 0.4 0 0.4 0.4 357 5 355 305 81 0 81 0 -11.7 0.1 -11.3 -12.1 12/09/2004 11:50:00 17 1.3 19.5 13.7 17.1 1.5 20.2 13 0.4 0 0.4 0.4 358 5 355 305 81 0 81 0 -11.7 0 -11.5 -12.1 12/09/2004 12:00:00 16.7 1.4 19.9 12.2 16.9 1.5 20.6 12.6 0.4 0 0.4 0.4 359 5 8 305 81 0 81 0 -11.6 0 -11.5 -11.9 12/09/2004 12:10:00 17.6 1.5 21 13.3 17.7 1.7 21.4 13 0.4 0 0.4 0.4 358 4 356 305 81 0 81 0 -11.6 0 -11.3 -11.9 12/09/2004 12:20:00 16.7 1.5 20.6 12.2 16.9 1.6 21 12.6 0.4 0 0.4 0.4 357 5 359 305 81 0 81 0 -11.4 0.1 -10.9 -11.7 12/09/2004 12:30:00 16.5 1.1 19.1 13.3 16.7 1.2 19.5 13.7 0.4 0 0.4 0.4 357 6 5 305 82 0 82 0 -11.2 0.2 -10.9 -11.5 12/09/2004 12:40:00 17.8 1.5 21.4 13 17.9 1.5 21.4 13.7 0.4 0 0.4 0.4 5 4 9 305 82 0 82 0 -10.7 0.1 -10.4 -10.9 12/09/2004 12:50:00 18.4 1.5 21.8 14.5 18.6 1.7 22.6 13.7 0.4 0 0.4 0.4 4 5 356 305 82 0 82 0 -10.8 0.1 -10.4 -11.1 12/09/2004 13:00:00 18.6 1.5 22.1 13.7 18.7 1.7 22.1 13.7 0.4 0 0.4 0.4 0 6 6 305 82 0 82 0 -11 0.3 -10.4 -11.7 12/09/2004 13:10:00 17.7 1.3 21.4 13.3 17.9 1.5 22.1 13.3 0.4 0 0.4 0.4 358 6 358 305 81 0 81 0 -11.5 0 -11.3 -11.9 12/09/2004 13:20:00 17.1 1.2 20.6 14.1 17.3 1.3 21 13.3 0.4 0 0.4 0.4 356 6 356 305 81 0 81 0 -11.5 0 -11.3 -11.7 12/09/2004 13:30:00 16.9 1.2 21 13 17 1.2 21 13.3 0.4 0 0.4 0.4 358 5 2 305 81 0 81 0 -11.5 0 -11.3 -11.7 12/09/2004 13:40:00 17.3 1.2 20.6 14.1 17.6 1.3 21 14.1 0.4 0 0.4 0.4 356 5 355 305 81 0 81 0 -11.4 0.1 -10.9 -11.7 12/09/2004 13:50:00 16.9 1.6 20.2 12.2 17 1.6 21 13 0.4 0 0.4 0.4 356 4 358 305 81 0 82 0 -11.1 0.1 -10.4 -11.5 12/09/2004 14:00:00 16.6 1.5 20.6 13 16.6 1.6 21 12.2 0.4 0 0.4 0.4 0 5 359 305 82 0 82 0 -10.9 0.2 -10.4 -11.3 12/09/2004 14:10:00 17.6 1.3 20.6 13.3 17.7 1.4 21 13.7 0.4 0 0.4 0.4 3 4 10 305 82 0 82 0 -10.7 0 -10.2 -10.9 12/09/2004 14:20:00 18.4 1.6 22.1 14.1 18.3 1.7 22.6 13.7 0.4 0 0.4 0.4 7 6 7 305 82 0 82 0 -10.4 0 -10 -10.9 12/09/2004 14:30:00 19.7 1.3 23.3 15.3 19.7 1.5 23.7 13.7 0.4 0 0.4 0.4 2 4 357 305 82 0 82 0 -10.6 0.1 -10.2 -11.1 12/09/2004 14:40:00 18.4 1.7 22.6 13.3 18.5 1.8 23.3 13.7 0.4 0 0.4 0.4 359 5 357 305 81 0 82 0 -11 0 -10.9 -11.3 12/09/2004 14:50:00 17.2 1.3 21 13.7 17.3 1.3 21 14.1 0.4 0 0.4 0.4 359 6 4 305 81 0 82 0 -10.9 0 -10.7 -11.3 12/09/2004 15:00:00 17.7 1.2 20.6 14.1 17.9 1.3 21 14.1 0.4 0 0.4 0.4 355 5 359 305 81 0 82 0 -11.1 0 -10.9 -11.5 12/09/2004 15:10:00 17.2 1.2 20.2 13 17.6 1.3 20.6 12.6 0.4 0 0.4 0.4 355 4 354 305 81 0 81 0 -11.1 0.1 -10.9 -11.3 12/09/2004 15:20:00 16.9 1.2 20.2 13 17.2 1.3 20.6 13.3 0.4 0 0.4 0.4 355 4 354 305 81 0 81 0 -11.2 0.1 -10.9 -11.5 12/09/2004 15:30:00 17.9 1 20.6 14.9 18.2 1.2 21.4 14.1 0.4 0 0.4 0.4 357 3 355 305 81 0 82 0 -11 0 -10.9 -11.3 12/09/2004 15:40:00 16.8 1.3 19.5 12.6 17.1 1.4 20.2 11.8 0.4 0 0.4 0.4 358 4 1 305 81 0 82 0 -10.8 0.1 -10.4 -11.1 12/09/2004 15:50:00 17.5 1.5 21.8 13 17.6 1.5 22.1 13.3 0.4 0 0.4 0.4 4 6 4 305 82 0 82 0 -10.3 0.2 -10 -10.9 12/09/2004 16:00:00 19.2 1.3 21.8 15.6 19 1.5 22.1 14.9 0.4 0 0.4 0.4 9 5 11 305 82 0 82 0 -10.1 0 -9.8 -10.4 12/09/2004 16:10:00 18.8 1.5 22.9 14.9 18.5 1.7 22.1 14.1 0.4 0 0.4 0.4 12 5 7 305 82 0 82 0 -10 0.1 -9.6 -10.2 12/09/2004 16:20:00 19.3 1.7 25.2 15.6 19 1.7 24.4 14.9 0.4 0 0.4 0.4 10 6 12 305 82 0 82 0 -10 0.1 -9.6 -10.4 12/09/2004 16:30:00 19.9 1.8 24 14.9 19.7 1.8 26 14.1 0.4 0 0.4 0.4 4 6 5 305 82 0 82 0 -10.5 0.2 -10.2 -11.1 12/09/2004 16:40:00 19.2 1.3 21.8 15.3 19.1 1.3 21.8 15.3 0.4 0 0.4 0.4 358 4 358 305 81 0 81 0 -11.1 0.1 -10.9 -11.3 12/09/2004 16:50:00 17.7 1.6 22.1 14.1 17.7 1.7 22.6 12.6 0.4 0 0.4 0.4 2 5 351 305 81 0 82 0 -10.8 0.3 -10 -11.3 12/09/2004 17:00:00 18.5 1.5 21.8 14.1 18.3 1.5 22.6 13.7 0.4 0 0.4 0.4 2 4 1 305 81 0 82 0 -10.5 0 -10.4 -10.9 12/09/2004 17:10:00 18.6 1.6 22.1 14.1 18.5 1.6 22.9 13.3 0.4 0 0.4 0.4 0 6 357 305 82 0 82 0 -10.5 0 -10.2 -10.9 12/09/2004 17:20:00 18.5 1.6 21.4 13.3 18.3 1.7 21.4 13.7 0.4 0 0.4 0.4 4 5 5 305 82 0 82 0 -10.3 0 -10 -10.4 12/09/2004 17:30:00 17.9 1.7 21.4 13.3 17.8 1.8 21.4 13 0.4 0 0.4 0.4 2 5 358 305 82 0 82 0 -10.3 0 -10 -10.7 12/09/2004 17:40:00 18 1.2 20.6 14.1 17.8 1.3 21.4 14.1 0.4 0 0.4 0.4 6 5 4 305 82 0 82 0 -10.3 0.1 -9.8 -10.4 12/09/2004 17:50:00 18.4 1.3 21.8 14.5 18.1 1.2 21 14.5 0.4 0 0.4 0.4 11 5 11 305 82 0 82 0 -10.3 0.1 -9.8 -10.4 12/09/2004 18:00:00 19.3 1.3 22.1 14.5 19.1 1.5 22.1 14.9 0.4 0 0.4 0.4 6 5 8 305 82 0 82 0 -10.3 0 -10 -10.4 12/09/2004 18:10:00 19.6 1.5 22.1 15.3 19.4 1.5 22.6 14.9 0.4 0 0.4 0.4 10 5 8 305 81 0 82 0 -10.4 0 -10 -10.7 12/09/2004 18:20:00 19.6 1.5 22.6 15.3 19.3 1.7 22.6 14.1 0.4 0 0.4 0.4 11 5 5 305 82 0 82 0 -10.3 0 -10 -10.4 12/09/2004 18:30:00 20.1 1.5 22.9 14.5 19.9 1.7 22.9 14.5 0.4 0 0.4 0.4 12 5 13 305 81 0 82 0 -10.3 0 -10 -10.7 12/09/2004 18:40:00 19.7 1.4 22.6 15.6 19.6 1.5 22.6 15.3 0.4 0 0.4 0.4 8 4 8 305 81 0 81 0 -10.5 0 -10.2 -10.9 12/09/2004 18:50:00 19 1.3 22.1 14.9 18.8 1.3 22.6 13.7 0.4 0 0.4 0.4 10 6 14 305 81 0 82 0 -10.3 0.1 -10 -10.7 12/09/2004 19:00:00 18.7 1.3 21.4 14.9 18.7 1.3 21.8 14.9 0.4 0 0.4 0.4 9 5 13 305 81 0 82 0 -10.4 0 -10 -10.7 12/09/2004 19:10:00 18.5 1.5 22.1 14.1 18.4 1.5 22.1 13.7 0.4 0 0.4 0.4 8 5 13 305 81 0 82 0 -10.4 0 -10 -10.7 12/09/2004 19:20:00 18.2 1.3 21 14.1 17.9 1.4 21 14.1 0.4 0 0.4 0.4 9 6 2 305 81 0 82 0 -10.4 0 -10 -10.7 12/09/2004 19:30:00 18.2 1.5 22.1 13.7 18 1.5 21.4 13 0.4 0 0.4 0.4 9 6 3 305 81 0 82 0 -10.4 0 -10 -10.7 12/09/2004 19:40:00 18.2 1.3 21.4 13.7 18 1.4 21 13.7 0.4 0 0.4 0.4 8 5 11 305 82 0 82 0 -10.3 0 -10 -10.7 12/09/2004 19:50:00 18.5 1.3 21.4 14.1 18.1 1.4 20.6 13 0.4 0 0.4 0.4 13 5 11 305 81 0 81 0 -10.3 0 -10 -10.4 12/09/2004 20:00:00 18.8 1.2 21.4 14.9 18.5 1.3 21.4 14.9 0.4 0 0.4 0.4 13 5 11 305 81 0 82 0 -10.2 0.1 -9.8 -10.4 12/09/2004 20:10:00 17.9 1.2 20.2 13.7 17.4 1.3 19.9 13.7 0.4 0 0.4 0.4 13 6 18 305 82 0 82 0 -10.1 0.1 -9.8 -10.4 12/09/2004 20:20:00 18.3 1.4 22.1 14.5 18 1.4 21.4 14.1 0.4 0 0.4 0.4 7 5 11 305 81 0 82 0 -10.3 0.1 -9.8 -10.4 12/09/2004 20:30:00 18.3 1.3 21 14.1 18 1.5 20.6 14.1 0.4 0 0.4 0.4 8 5 359 305 81 0 82 0 -10.3 0.1 -9.8 -10.4 12/09/2004 20:40:00 19 1.2 21.8 16.1 18.8 1.2 21.8 15.3 0.4 0 0.4 0.4 6 5 3 305 81 0 82 0 -10.4 0 -10 -10.7 12/09/2004 20:50:00 17.7 1.6 21 13.3 17.4 1.7 21.8 13.3 0.4 0 0.4 0.4 7 5 12 305 82 0 82 0 -10.1 0.1 -9.8 -10.4 12/09/2004 21:00:00 18.3 1.3 21.4 14.1 18.1 1.3 21.4 14.1 0.4 0 0.4 0.4 4 5 12 305 82 0 82 0 -10.3 0 -10 -10.7 12/09/2004 21:10:00 19 1.4 22.6 15.3 18.8 1.6 22.9 13.7 0.4 0 0.4 0.4 7 4 1 305 82 0 82 0 -10.3 0 -10 -10.4 12/09/2004 21:20:00 18.6 1.3 21.4 15.3 18.3 1.5 21 14.1 0.4 0 0.4 0.4 7 5 5 305 81 0 82 0 -10.3 0.1 -9.8 -10.7 12/09/2004 21:30:00 19.1 1.1 21.8 15.6 18.8 1.3 21.8 14.9 0.4 0 0.4 0.4 7 5 11 305 81 0 82 0 -10.3 0 -10 -10.4 12/09/2004 21:40:00 19.2 1.4 21.8 13.7 18.8 1.6 22.1 14.1 0.4 0 0.4 0.4 8 5 9 305 81 0 82 0 -10.3 0 -10 -10.7 12/09/2004 21:50:00 19.7 1.1 21.8 15.6 19.5 1.1 21.8 15.3 0.4 0 0.4 0.4 9 4 15 305 81 0 82 0 -10.3 0 -10 -10.4 12/09/2004 22:00:00 19 1.2 22.1 15.3 18.8 1.4 21.8 14.5 0.4 0 0.4 0.4 8 5 9 305 81 0 82 0 -10.3 0 -10 -10.7 12/09/2004 22:10:00 18.5 1.2 21.8 15.3 18.1 1.2 21.4 14.9 0.4 0 0.4 0.4 9 5 11 305 81 0 82 0 -10.2 0.1 -9.8 -10.4 12/09/2004 22:20:00 18.7 1.1 21 15.3 18.3 1.3 21 14.1 0.4 0 0.4 0.4 13 5 14 305 81 0 82 0 -10.3 0.1 -9.8 -10.4 12/09/2004 22:30:00 18.4 1.3 21 13.3 18.2 1.3 21 14.5 0.4 0 0.4 0.4 9 5 8 305 81 0 82 0 -10.3 0 -10 -10.4 12/09/2004 22:40:00 18.8 1.1 21.4 14.5 18.3 1.3 21 14.1 0.4 0 0.4 0.4 10 6 7 305 81 0 82 0 -10.3 0 -10 -10.4 12/09/2004 22:50:00 17.7 1.5 21.4 13 17.6 1.5 21 13.3 0.4 0 0.4 0.4 10 6 8 305 81 0 82 0 -10.2 0.1 -9.6 -10.7 12/09/2004 23:00:00 17.6 1.2 19.9 13.3 17.3 1.3 20.2 12.6 0.4 0 0.4 0.4 9 5 4 305 82 0 82 0 -10.1 0.1 -9.8 -10.4 12/09/2004 23:10:00 18.1 1 20.6 15.6 17.7 1.1 20.6 14.9 0.4 0 0.4 0.4 17 5 12 305 82 0 82 0 -10 0 -9.6 -10.2 12/09/2004 23:20:00 17.4 1.2 21 13.7 17.2 1.3 20.2 13.3 0.4 0 0.4 0.4 15 5 12 305 82 0 82 0 -10 0.1 -9.6 -10.2 12/09/2004 23:30:00 17.3 1.5 19.9 13.3 17 1.6 19.9 13 0.4 0 0.4 0.4 11 4 9 305 82 0 82 0 -10.1 0 -9.8 -10.4 12/09/2004 23:40:00 17.1 1.1 20.2 14.1 16.7 1.2 19.9 12.6 0.4 0 0.4 0.4 13 5 24 305 82 0 82 0 -9.9 0 -9.6 -10 12/09/2004 23:50:00 17.3 1.5 20.6 13.3 17 1.6 20.6 12.6 0.4 0 0.4 0.4 15 6 20 305 82 0 82 0 -9.8 0 -9.6 -10 12/10/2004 00:00:00 17.8 1.4 21 14.1 17.5 1.4 20.6 13.3 0.4 0 0.4 0.4 13 5 12 305 82 0 82 0 -9.9 0 -9.6 -10 12/10/2004 00:10:00 17.4 1.2 20.2 14.1 17.1 1.3 20.6 13 0.4 0 0.4 0.4 14 5 21 305 82 0 82 0 -9.9 0 -9.4 -10 12/10/2004 00:20:00 17.3 1.2 19.9 14.1 17 1.3 19.5 13.3 0.4 0 0.4 0.4 14 5 15 305 82 0 82 0 -9.8 0.1 -9.4 -10 12/10/2004 00:30:00 17.7 1.1 20.2 14.1 17.4 1.3 20.6 13.7 0.4 0 0.4 0.4 16 4 15 305 82 0 82 0 -9.9 0 -9.6 -10.2 12/10/2004 00:40:00 17.4 1.3 20.6 13.7 17.2 1.4 20.2 13 0.4 0 0.4 0.4 16 4 17 305 82 0 82 0 -10 0 -9.6 -10.2 12/10/2004 00:50:00 18 1.3 20.6 13.7 17.8 1.5 20.2 13.3 0.4 0 0.4 0.4 13 5 13 305 81 0 82 0 -10.2 0.1 -9.8 -10.4 12/10/2004 01:00:00 17.4 1.3 20.6 13.7 17.1 1.5 20.2 13 0.4 0 0.4 0.4 14 5 10 305 81 0 82 0 -10.2 0.1 -9.8 -10.4 12/10/2004 01:10:00 17.6 1 19.9 14.5 17.3 1.2 20.2 14.1 0.4 0 0.4 0.4 16 4 17 305 81 0 82 0 -10.2 0.1 -10 -10.4 12/10/2004 01:20:00 17 1.4 20.6 13.3 16.6 1.5 21 13 0.4 0 0.4 0.4 15 6 22 305 81 0 82 0 -10.2 0.1 -9.8 -10.4 12/10/2004 01:30:00 17.1 1.1 19.1 13.7 16.8 1.3 19.1 13 0.4 0 0.4 0.4 11 4 13 305 81 0 82 0 -10.3 0 -10 -10.7 12/10/2004 01:40:00 16.9 1.2 19.9 13.7 16.6 1.2 19.9 13.3 0.4 0 0.4 0.4 15 6 18 305 81 0 81 0 -10.4 0 -10 -10.4 12/10/2004 01:50:00 17.2 1 19.5 13 16.9 1 19.5 13.7 0.4 0 0.4 0.4 13 6 21 305 81 0 81 0 -10.4 0 -10.2 -10.7 12/10/2004 02:00:00 16.7 1.2 19.5 13 16.6 1.3 19.5 12.6 0.4 0 0.4 0.4 12 5 14 305 81 0 81 0 -10.4 0 -10 -10.4 12/10/2004 02:10:00 17.2 1.1 19.5 13.7 16.9 1.1 19.1 13.3 0.4 0 0.4 0.4 19 4 18 305 81 0 81 0 -10.4 0 -10.2 -10.4 12/10/2004 02:20:00 16.7 1.2 19.5 13.3 16.5 1.3 19.5 12.6 0.4 0 0.4 0.4 15 5 13 305 81 0 81 0 -10.3 0 -10 -10.4 12/10/2004 02:30:00 16.5 1.2 19.5 13 16.2 1.4 19.1 13 0.4 0 0.4 0.4 16 6 24 305 81 0 81 0 -10.3 0 -10 -10.4 12/10/2004 02:40:00 16.3 1.2 19.5 13.3 16 1.2 18.7 12.6 0.4 0 0.4 0.4 13 6 14 305 81 0 82 0 -10.2 0 -10 -10.4 12/10/2004 02:50:00 16.4 1 18.3 12.6 16.2 1.1 18.7 13.3 0.4 0 0.4 0.4 12 4 12 305 81 0 82 0 -10.2 0.1 -9.8 -10.4 12/10/2004 03:00:00 16.7 1.2 19.1 12.6 16.5 1.3 19.1 12.6 0.4 0 0.4 0.4 12 6 19 305 81 0 82 0 -10.3 0 -10 -10.7 12/10/2004 03:10:00 16.3 1 19.1 13.3 16.2 1.2 18.7 12.6 0.4 0 0.4 0.4 13 5 17 305 81 0 81 0 -10.3 0 -10 -10.4 12/10/2004 03:20:00 15.6 1.3 18.7 11.8 15.4 1.3 18.3 11.5 0.4 0 0.4 0.4 13 4 20 305 81 0 82 0 -10.3 0.1 -9.8 -10.4 12/10/2004 03:30:00 16.2 1 18.7 13.3 16.1 1.1 19.5 12.6 0.4 0 0.4 0.4 10 5 10 305 81 0 82 0 -10.3 0 -10 -10.4 12/10/2004 03:40:00 15.9 1 17.9 13.3 15.8 1.1 18.3 11.5 0.4 0 0.4 0.4 11 5 12 305 81 0 82 0 -10.2 0.1 -9.8 -10.4 12/10/2004 03:50:00 15.8 1 17.9 12.2 15.7 1 17.9 11.8 0.4 0 0.4 0.4 12 5 4 305 81 0 82 0 -10.3 0 -9.8 -10.4 12/10/2004 04:00:00 15.7 1 17.9 12.2 15.5 1.2 18.3 11.8 0.4 0 0.4 0.4 9 4 11 305 81 0 82 0 -10.2 0 -10 -10.4 12/10/2004 04:10:00 15.3 1 17.6 12.6 15.1 1 17.6 12.2 0.4 0 0.4 0.4 11 4 8 305 81 0 82 0 -10.1 0 -9.8 -10.4 12/10/2004 04:20:00 15.2 1 17.9 12.2 15 1 17.6 11.8 0.4 0 0.4 0.4 16 5 24 305 81 0 82 0 -10 0 -9.6 -10.2 12/10/2004 04:30:00 15.7 1 17.9 12.6 15.6 1.1 17.9 11.1 0.4 0 0.4 0.4 10 4 12 305 82 0 82 0 -10 0 -9.6 -10.2 12/10/2004 04:40:00 15.3 1.1 17.9 11.1 15.1 1.2 17.6 11.1 0.4 0 0.4 0.4 13 5 11 305 82 0 82 0 -9.9 0 -9.6 -10 12/10/2004 04:50:00 16.2 1 18.3 12.6 16 1.1 18.3 12.6 0.4 0 0.4 0.4 10 4 12 305 82 0 82 0 -10 0 -9.6 -10.2 12/10/2004 05:00:00 16 1 17.9 12.6 15.9 1.1 17.9 11.8 0.4 0 0.4 0.4 12 3 16 305 81 0 82 0 -10 0 -9.8 -10.2 12/10/2004 05:10:00 16.1 1.1 18.3 11.8 15.7 1.2 17.9 11.8 0.4 0 0.4 0.4 11 4 9 305 82 0 82 0 -9.9 0 -9.8 -10.2 12/10/2004 05:20:00 15.7 1.2 17.9 11.8 15.5 1.3 18.3 12.2 0.4 0 0.4 0.4 11 5 11 305 82 0 82 0 -9.9 0.1 -9.6 -10 12/10/2004 05:30:00 16.8 1.1 19.9 12.6 16.5 1.2 19.5 12.2 0.4 0 0.4 0.4 13 5 19 305 82 0 82 0 -9.8 0 -9.4 -10 12/10/2004 05:40:00 16.2 1.2 18.3 11.8 15.9 1.2 18.3 12.2 0.4 0 0.4 0.4 17 5 21 305 82 0 82 0 -9.7 0 -9.4 -10 12/10/2004 05:50:00 16.8 1 18.7 13.7 16.6 1 18.7 13.3 0.4 0 0.4 0.4 13 4 8 305 82 0 82 0 -9.8 0 -9.6 -10 12/10/2004 06:00:00 17.2 1.2 19.9 13.3 16.8 1.3 19.9 13.3 0.4 0 0.4 0.4 12 4 9 305 81 0 82 0 -9.9 0 -9.6 -10 12/10/2004 06:10:00 16.8 1.3 19.5 13 16.6 1.4 19.5 12.6 0.4 0 0.4 0.4 11 5 12 305 81 0 82 0 -10 0 -9.8 -10.2 12/10/2004 06:20:00 16.6 1.1 18.7 12.6 16.3 1.1 18.7 12.6 0.4 0 0.4 0.4 11 5 6 305 81 0 82 0 -10 0 -9.6 -10.2 12/10/2004 06:30:00 16.4 1.1 18.7 13.3 16.3 1.2 19.5 12.2 0.4 0 0.4 0.4 9 5 1 305 82 0 82 0 -9.9 0 -9.6 -10 12/10/2004 06:40:00 16.7 1 19.1 13.3 16.6 1 19.1 13.7 0.4 0 0.4 0.4 10 4 13 305 82 0 82 0 -9.9 0 -9.6 -10 12/10/2004 06:50:00 16.7 1 18.7 13.7 16.5 1 18.7 13.7 0.4 0 0.4 0.4 11 3 10 305 82 0 82 0 -9.8 0 -9.6 -10 12/10/2004 07:00:00 16.3 1 18.7 13.3 16.1 1 18.7 13 0.4 0 0.4 0.4 10 4 10 305 82 0 82 0 -9.7 0 -9.6 -9.8 12/10/2004 07:10:00 16.5 0.9 18.3 12.6 16.2 1 17.9 12.2 0.4 0 0.4 0.4 14 4 17 305 82 0 82 0 -9.7 0 -9.4 -9.8 12/10/2004 07:20:00 16.4 1.2 18.7 12.6 16.2 1.3 18.7 12.2 0.4 0 0.4 0.4 11 4 8 305 82 0 82 0 -9.6 0 -9.4 -9.8 12/10/2004 07:30:00 15.7 1.2 18.3 11.5 15.6 1.3 18.7 11.1 0.4 0 0.4 0.4 11 5 8 305 82 0 82 0 -9.7 0.1 -9.2 -9.8 12/10/2004 07:40:00 15.4 1.1 17.9 12.2 15.2 1.2 17.9 11.5 0.4 0 0.4 0.4 12 5 16 305 82 0 82 0 -9.6 0 -9.2 -9.8 12/10/2004 07:50:00 15.5 1.1 17.9 12.2 15.3 1.2 17.9 11.8 0.4 0 0.4 0.4 12 5 7 305 82 0 82 0 -9.6 0 -9.2 -9.8 12/10/2004 08:00:00 16.3 1 18.3 13.7 16.1 1 18.3 13 0.4 0 0.4 0.4 16 4 16 305 82 0 82 0 -9.5 0 -9.2 -9.6 12/10/2004 08:10:00 15.8 0.8 17.6 13 15.6 1 17.9 12.6 0.4 0 0.4 0.4 12 4 11 305 82 0 82 0 -9.5 0 -9.2 -9.6 12/10/2004 08:20:00 14.7 1 17.6 12.2 14.6 1.1 17.2 11.1 0.4 0 0.4 0.4 16 4 16 305 82 0 82 0 -9.5 0.1 -9.2 -9.8 12/10/2004 08:30:00 15.3 0.8 17.6 12.6 15.2 0.9 17.6 12.2 0.4 0 0.4 0.4 16 5 19 305 82 0 82 0 -9.6 0.1 -9.2 -9.8 12/10/2004 08:40:00 14.9 1 17.2 12.2 14.7 1.1 17.6 11.5 0.4 0 0.4 0.4 18 5 22 305 82 0 82 0 -9.5 0.1 -9.2 -9.8 12/10/2004 08:50:00 15.3 1 17.6 13 15.2 1 17.6 12.6 0.4 0 0.4 0.4 15 5 15 305 82 0 82 0 -9.6 0 -9.2 -9.8 12/10/2004 09:00:00 14.9 1 17.6 11.8 14.8 1.1 17.2 11.1 0.4 0 0.4 0.4 15 5 15 305 82 0 82 0 -9.5 0 -9.2 -9.8 12/10/2004 09:10:00 14.7 1.1 17.6 11.5 14.5 1.2 17.2 11.1 0.4 0 0.4 0.4 14 5 10 305 82 0 82 0 -9.5 0 -9.2 -9.6 12/10/2004 09:20:00 14.7 1 17.6 11.8 14.7 1 17.6 11.5 0.4 0 0.4 0.4 13 4 17 305 82 0 82 0 -9.4 0 -9.2 -9.6 12/10/2004 09:30:00 14.2 1.1 16.8 11.1 14.2 1.2 17.2 10.7 0.4 0 0.4 0.4 13 5 6 305 82 0 82 0 -9.4 0 -9 -9.6 12/10/2004 09:40:00 14.6 0.8 16.4 12.2 14.5 0.9 16.4 11.8 0.4 0 0.4 0.4 12 4 13 305 82 0 82 0 -9.4 0 -9 -9.6 12/10/2004 09:50:00 14.5 1 16.8 11.5 14.5 1.1 16.8 11.8 0.4 0 0.4 0.4 11 5 4 305 82 0 82 0 -9.4 0 -8.8 -9.6 12/10/2004 10:00:00 15 1 17.6 11.5 14.8 1 16.8 11.8 0.4 0 0.4 0.4 15 4 18 305 82 0 82 0 -9.3 0 -9 -9.4 12/10/2004 10:10:00 14.3 0.9 16.1 11.5 14.3 1 16.1 11.5 0.4 0 0.4 0.4 10 4 11 305 82 0 82 0 -9.3 0 -9 -9.4 12/10/2004 10:20:00 14.7 1 17.6 11.1 14.7 1 17.2 11.5 0.4 0 0.4 0.4 9 4 12 305 82 0 82 0 -9.2 0.1 -8.8 -9.4 12/10/2004 10:30:00 15.2 1.1 17.9 11.8 15.2 1.2 17.6 11.5 0.4 0 0.4 0.4 8 4 4 305 83 0 83 0 -9 0 -8.8 -9.2 12/10/2004 10:40:00 15.6 1.1 18.3 12.2 15.3 1.2 17.9 12.2 0.4 0 0.4 0.4 12 4 10 305 83 0 83 0 -8.8 0.1 -8.4 -9.2 12/10/2004 10:50:00 15.6 0.8 17.9 13.3 15.5 1 17.9 13 0.4 0 0.4 0.4 13 3 8 305 83 0 83 0 -8.7 0 -8.4 -8.8 12/10/2004 11:00:00 15.7 1 18.3 12.6 15.7 1 18.3 12.6 0.4 0 0.4 0.4 12 5 8 305 83 0 83 0 -8.7 0 -8.4 -9 12/10/2004 11:10:00 15.5 1 17.9 13.3 15.4 1 18.3 12.6 0.4 0 0.4 0.4 13 5 13 305 83 0 83 0 -8.7 0 -8.4 -8.8 12/10/2004 11:20:00 15.7 0.8 17.9 13 15.6 0.8 17.6 13 0.4 0 0.4 0.4 15 3 10 305 83 0 83 0 -8.7 0 -8.6 -8.8 12/10/2004 11:30:00 15.8 0.9 17.2 12.6 15.7 0.9 17.9 12.6 0.4 0 0.4 0.4 16 5 14 305 83 0 83 0 -8.7 0 -8.6 -8.8 12/10/2004 11:40:00 15.6 1 17.9 12.6 15.3 1.1 18.3 11.8 0.4 0 0.4 0.4 21 4 23 305 83 0 82 0 -8.7 0 -8.4 -8.8 12/10/2004 11:50:00 15.8 0.8 18.3 13.3 15.6 0.9 17.6 12.6 0.4 0 0.4 0.4 18 5 21 305 83 0 82 0 -8.8 0 -8.4 -9 12/10/2004 12:00:00 15.5 1 17.9 12.6 15.3 1 17.9 12.6 0.4 0 0.4 0.4 18 5 15 305 83 0 82 0 -8.7 0 -8.4 -9 12/10/2004 12:10:00 15.3 1 18.3 12.6 15 1.1 17.9 12.6 0.4 0 0.4 0.4 17 4 14 305 83 0 83 0 -8.6 0.1 -8.4 -8.8 12/10/2004 12:20:00 15.3 1.1 17.9 12.2 15.1 1 17.6 11.8 0.4 0 0.4 0.4 21 5 21 305 83 0 83 0 -8.6 0 -8.2 -8.8 12/10/2004 12:30:00 15 0.9 16.8 11.8 14.7 1 16.8 11.5 0.4 0 0.4 0.4 23 5 20 305 83 0 83 0 -8.5 0.1 -8.2 -8.8 12/10/2004 12:40:00 14.8 1 17.2 11.8 14.5 1.1 17.2 10.7 0.4 0 0.4 0.4 26 4 29 305 83 0 82 0 -8.5 0 -8.2 -8.8 12/10/2004 12:50:00 14.8 1 16.8 11.8 14.7 1 16.8 11.5 0.4 0 0.4 0.4 24 5 24 305 83 0 83 0 -8.5 0 -8.2 -8.6 12/10/2004 13:00:00 14.8 1 17.2 11.5 14.7 1.1 17.6 11.8 0.4 0 0.4 0.4 27 5 21 305 83 0 83 0 -8.3 0 -8.2 -8.4 12/10/2004 13:10:00 14.7 1 16.8 11.8 14.5 1.1 17.2 11.5 0.4 0 0.4 0.4 28 4 30 305 83 0 83 0 -8.2 0 -7.9 -8.4 12/10/2004 13:20:00 14.9 0.9 17.2 12.2 14.6 1 17.2 11.5 0.4 0 0.4 0.4 25 5 21 305 83 0 83 0 -8.2 0 -7.9 -8.4 12/10/2004 13:30:00 15.4 0.8 17.2 13 15.3 0.9 17.9 12.6 0.4 0 0.4 0.4 26 4 27 305 83 0 83 0 -8.3 0 -7.9 -8.4 12/10/2004 13:40:00 15.8 0.9 17.9 13.3 15.4 1 17.6 12.6 0.4 0 0.4 0.4 27 4 26 305 83 0 83 0 -8.3 0 -7.9 -8.4 12/10/2004 13:50:00 15.9 0.9 18.3 13 15.8 0.9 18.3 13 0.4 0 0.4 0.4 26 4 19 305 83 0 84 0 -8.4 0 -8.2 -8.6 12/10/2004 14:00:00 15.9 0.8 18.3 13.3 15.7 0.9 17.9 13 0.4 0 0.4 0.4 27 3 25 305 83 0 84 0 -8.2 0 -8.2 -8.4 12/10/2004 14:10:00 15.8 0.9 17.6 13 15.5 1 18.3 13 0.4 0 0.4 0.4 26 5 25 305 84 0 83 0 -8.2 0 -7.7 -8.4 12/10/2004 14:20:00 15.8 1 18.7 12.6 15.7 1.1 18.3 11.8 0.4 0 0.4 0.4 24 4 22 305 84 0 84 0 -8.2 0 -7.9 -8.4 12/10/2004 14:30:00 15.5 1 17.6 12.2 15.3 1.1 17.6 12.2 0.4 0 0.4 0.4 27 4 22 305 84 0 84 0 -8.2 0 -7.9 -8.4 12/10/2004 14:40:00 15.2 0.8 17.2 12.6 15 1 17.6 13 0.4 0 0.4 0.4 28 4 29 305 83 0 83 0 -8.2 0 -7.9 -8.6 12/10/2004 14:50:00 15.4 0.9 17.6 13 15.2 1 17.2 12.6 0.4 0 0.4 0.4 25 4 21 305 83 0 84 0 -8.4 0 -8.2 -8.6 12/10/2004 15:00:00 14.9 0.7 16.4 12.6 14.8 0.9 16.8 12.2 0.4 0 0.4 0.4 24 3 25 305 84 0 84 0 -8.3 0 -8.2 -8.4 12/10/2004 15:10:00 14 0.6 15.6 12.2 13.8 0.7 15.6 11.5 0.4 0 0.4 0.4 25 4 27 305 84 0 84 0 -8.2 0 -7.9 -8.4 12/10/2004 15:20:00 13.6 0.8 15.6 10.7 13.5 0.8 15.6 10.3 0.4 0 0.4 0.4 26 4 26 305 84 0 84 0 -8.2 0 -7.9 -8.4 12/10/2004 15:30:00 13 1 15.3 10.3 12.8 1 15.6 10.3 0.4 0 0.4 0.4 22 5 27 305 84 0 84 0 -8.2 0 -7.7 -8.4 12/10/2004 15:40:00 12.7 2 16.8 7.6 12.5 2.1 16.4 7.6 0.4 0 0.4 0.4 30 10 40 305 84 0 84 0 -7.7 0.2 -7.3 -7.9 12/10/2004 15:50:00 9 1.3 12.2 6.5 8.9 1.2 12.2 6.5 0.4 0 0.4 0.4 54 9 39 305 83 0 84 0 -7.7 0 -7.3 -7.9 12/10/2004 16:00:00 11 1 13.3 8.4 10.4 1.1 13 7.6 0.4 0 0.4 0.4 66 4 70 305 83 0 83 0 -7.8 0 -7.7 -7.9 12/10/2004 16:10:00 12.5 0.9 14.1 9.9 12.2 1 14.5 9.1 0.4 0 0.4 0.4 56 5 60 305 83 0 83 0 -7.7 0 -7.5 -7.7 12/10/2004 16:20:00 12.4 0.8 14.5 9.9 12.1 0.9 14.5 9.1 0.4 0 0.4 0.4 57 6 50 305 83 0 83 0 -7.6 0 -7.3 -7.7 12/10/2004 16:30:00 12.5 1.2 15.3 9.5 12.3 1.3 15.3 8.4 0.4 0 0.4 0.4 57 7 62 305 82 0 82 0 -7.7 0 -7.3 -7.9 12/10/2004 16:40:00 13 1 14.9 10.3 12.7 1.1 14.9 9.9 0.4 0 0.4 0.4 55 5 57 305 82 0 82 0 -7.7 0 -7.5 -7.9 12/10/2004 16:50:00 11.7 1.2 14.9 9.1 11.3 1.3 14.9 8.8 0.4 0 0.4 0.4 57 7 48 305 82 0 82 0 -7.9 0 -7.7 -8.2 12/10/2004 17:00:00 11.9 1.1 14.5 8.8 11.6 1.2 14.5 8.8 0.4 0 0.4 0.4 54 5 56 305 82 0 82 0 -7.9 0 -7.7 -7.9 12/10/2004 17:10:00 11.3 0.7 13.3 8.8 11.2 0.8 13.3 8.8 0.4 0 0.4 0.4 50 5 43 305 82 0 82 0 -7.9 0 -7.7 -8.2 12/10/2004 17:20:00 11 0.9 13 8.8 10.7 0.9 13 7.6 0.4 0 0.4 0.4 52 4 47 305 83 0 82 0 -7.8 0 -7.3 -8.2 12/10/2004 17:30:00 12.3 0.9 14.5 9.9 12.1 1 14.1 9.5 0.4 0 0.4 0.4 53 4 52 305 83 0 83 0 -7.7 0 -7.3 -7.7 12/10/2004 17:40:00 11.6 1.2 14.5 8.4 11.3 1.2 13.7 8.4 0.4 0 0.4 0.4 58 7 48 305 83 0 83 0 -7.7 0.1 -7.3 -7.9 12/10/2004 17:50:00 11.6 0.9 13.7 9.5 11.2 1 14.1 8 0.4 0 0.4 0.4 54 7 62 305 83 0 83 0 -7.6 0.1 -7.1 -7.9 12/10/2004 18:00:00 11.4 0.9 13.3 9.1 11.2 0.9 13.3 9.1 0.4 0 0.4 0.4 51 7 58 305 83 0 83 0 -7.5 0.1 -7.3 -7.7 12/10/2004 18:10:00 12.2 0.9 15.3 10.3 11.9 0.9 14.9 9.1 0.4 0 0.4 0.4 53 4 50 305 83 0 83 0 -7.6 0 -7.3 -7.7 12/10/2004 18:20:00 11.9 1.1 14.1 8.8 11.6 1.1 14.1 8 0.4 0 0.4 0.4 52 5 61 305 83 0 83 0 -7.6 0 -7.3 -7.7 12/10/2004 18:30:00 11.7 0.9 14.5 9.1 11.4 0.9 13.7 8.4 0.4 0 0.4 0.4 54 7 57 305 83 0 83 0 -7.6 0 -7.3 -7.7 12/10/2004 18:40:00 13.7 1.8 16.8 9.5 13.5 1.7 16.8 8.8 0.4 0 0.4 0.4 35 7 25 305 83 0 84 0 -7.8 0.2 -7.5 -8.2 12/10/2004 18:50:00 15.9 0.8 17.9 13.7 15.6 0.9 17.9 13.7 0.4 0 0.4 0.4 27 4 28 305 83 0 84 0 -8 0 -7.7 -8.2 12/10/2004 19:00:00 16.6 0.8 18.7 14.9 16.4 0.9 18.3 13.7 0.4 0 0.4 0.4 25 4 25 305 83 0 84 0 -8.2 0 -7.9 -8.2 12/10/2004 19:10:00 16.1 0.9 18.3 13.3 15.9 1 18.3 13.3 0.4 0 0.4 0.4 24 5 25 305 83 0 82 0 -8 0.1 -7.7 -8.2 12/10/2004 19:20:00 16.4 1.1 21 13.7 16.1 1.1 20.2 13 0.4 0 0.4 0.4 24 5 22 305 83 0 83 0 -8.2 0 -7.9 -8.4 12/10/2004 19:30:00 15.7 1 17.6 13 15.4 1 17.9 12.6 0.4 0 0.4 0.4 25 6 23 305 83 0 82 0 -8.3 0 -7.9 -8.4 12/10/2004 19:40:00 16.2 0.9 18.3 13.7 16 1 18.3 12.6 0.4 0 0.4 0.4 23 4 22 305 82 0 82 0 -8.4 0.1 -8.2 -8.8 12/10/2004 19:50:00 16.2 0.9 18.7 13.7 15.9 1 18.3 13 0.4 0 0.4 0.4 28 5 27 305 82 0 82 0 -8.6 0.1 -8.4 -8.8 12/10/2004 20:00:00 16.2 0.9 17.9 13.3 16 1 17.9 13.7 0.4 0 0.4 0.4 25 4 29 305 82 0 82 0 -8.5 0 -8.4 -8.8 12/10/2004 20:10:00 16.1 1 18.3 13.3 15.8 1.1 18.3 12.6 0.4 0 0.4 0.4 24 5 23 305 82 0 82 0 -8.5 0 -8.4 -8.8 12/10/2004 20:20:00 16.8 0.9 19.1 14.1 16.5 1 19.1 14.1 0.4 0 0.4 0.4 24 4 22 305 82 0 82 0 -8.4 0 -8.2 -8.6 12/10/2004 20:30:00 16.2 1 18.7 13.7 15.9 1.1 18.3 12.6 0.4 0 0.4 0.4 26 5 29 305 82 0 82 0 -8.4 0.1 -8.2 -8.8 12/10/2004 20:40:00 17.2 0.9 19.1 14.5 17 1 18.7 13.7 0.4 0 0.4 0.4 27 4 25 305 82 0 82 0 -8.6 0 -8.4 -8.8 12/10/2004 20:50:00 17.4 0.8 20.2 14.9 17.2 0.8 19.5 14.5 0.4 0 0.4 0.4 27 5 24 305 81 0 82 0 -8.7 0 -8.4 -8.8 12/10/2004 21:00:00 17.6 1 20.6 13.7 17.2 1.1 19.5 13.3 0.4 0 0.4 0.4 27 5 25 305 81 0 81 0 -8.8 0 -8.8 -9 12/10/2004 21:10:00 17.5 1.1 20.6 14.9 17 1.2 19.5 13.3 0.4 0 0.4 0.4 31 4 39 305 81 0 81 0 -8.9 0 -8.8 -9.2 12/10/2004 21:20:00 17.8 1.1 19.9 14.1 17.5 1.2 19.5 13.3 0.4 0 0.4 0.4 30 4 25 305 81 0 81 0 -9.1 0.1 -8.8 -9.2 12/10/2004 21:30:00 18.6 1.3 21.8 14.5 18 1.3 21 14.1 0.4 0 0.4 0.4 36 5 26 305 81 0 81 0 -9.1 0.1 -8.8 -9.2 12/10/2004 21:40:00 18.5 1.1 21.4 14.5 18 1.3 21.4 14.1 0.4 0 0.4 0.4 31 5 25 305 81 0 81 0 -9.1 0 -8.8 -9.2 12/10/2004 21:50:00 19.6 1.1 22.6 15.6 19.1 1.1 21.8 15.3 0.4 0 0.4 0.4 30 4 21 305 80 0 81 0 -9.3 0.1 -8.8 -9.6 12/10/2004 22:00:00 18.9 1.5 22.6 14.5 18.4 1.5 21.4 14.9 0.4 0 0.4 0.4 34 5 35 305 80 0 80 0 -9.3 0.1 -9 -9.6 12/10/2004 22:10:00 18.1 1.2 20.6 14.5 17.6 1.2 20.6 14.1 0.4 0 0.4 0.4 34 7 35 305 80 0 80 0 -9.3 0 -9 -9.4 12/10/2004 22:20:00 18.9 1.3 21.8 14.1 18.4 1.3 22.1 15.3 0.4 0 0.4 0.4 27 5 30 305 81 0 81 0 -9.2 0 -9 -9.2 12/10/2004 22:30:00 17.7 1.1 20.2 14.9 17.3 1.2 19.9 14.1 0.4 0 0.4 0.4 37 6 41 305 81 0 81 0 -9 0 -8.8 -9.2 12/10/2004 22:40:00 18.5 1.5 22.6 14.9 18 1.6 22.1 13.7 0.4 0 0.4 0.4 40 5 36 305 81 0 81 0 -9.1 0 -8.8 -9.2 12/10/2004 22:50:00 18 1.4 21 14.5 17.5 1.5 21 13.7 0.4 0 0.4 0.4 37 6 42 305 81 0 81 0 -9 0.1 -8.6 -9.2 12/10/2004 23:00:00 19.2 1.5 22.1 15.6 18.7 1.5 22.6 14.5 0.4 0 0.4 0.4 37 5 33 305 81 0 81 0 -9 0 -8.8 -9.2 12/10/2004 23:10:00 18.9 1.2 22.1 14.9 18.4 1.3 21.8 13.7 0.4 0 0.4 0.4 34 4 31 305 81 0 81 0 -9.1 0 -8.8 -9.2 12/10/2004 23:20:00 19.3 1.3 22.6 15.3 18.7 1.4 21.4 14.9 0.4 0 0.4 0.4 30 5 32 305 81 0 81 0 -9 0 -8.8 -9.2 12/10/2004 23:30:00 18.8 1.5 21.8 14.9 18.3 1.5 21.8 14.9 0.4 0 0.4 0.4 36 7 33 305 81 0 82 0 -8.8 0 -8.4 -9 12/10/2004 23:40:00 20.3 1.2 23.7 16.8 19.7 1.3 23.3 16.4 0.4 0 0.4 0.4 33 6 29 305 81 0 82 0 -8.9 0 -8.8 -9.2 12/10/2004 23:50:00 20.1 1.4 22.9 16.8 19.5 1.5 22.9 15.6 0.4 0 0.4 0.4 35 5 30 305 81 0 82 0 -8.9 0.1 -8.4 -9.2 12/11/2004 00:00:00 20.5 1.8 24.4 14.5 19.9 1.8 24 14.9 0.4 0 0.4 0.4 30 5 29 305 82 0 82 0 -8.7 0 -8.4 -8.8 12/11/2004 00:10:00 20.9 1.6 24.4 16.8 20.2 1.6 23.3 15.3 0.4 0 0.4 0.4 33 5 30 305 82 0 82 0 -8.6 0.1 -8.4 -8.8 12/11/2004 00:20:00 21 1.6 24.4 16.4 20.5 1.7 25.2 16.4 0.4 0 0.4 0.4 30 5 23 305 82 0 82 0 -8.6 0.1 -8.2 -8.8 12/11/2004 00:30:00 21.4 1.3 24.8 17.2 20.9 1.3 24 17.2 0.4 0 0.4 0.4 34 6 28 305 82 0 82 0 -8.6 0.1 -8.2 -8.8 12/11/2004 00:40:00 19.8 1.4 24.4 16.8 19.2 1.4 22.6 15.6 0.4 0 0.4 0.4 38 7 37 305 82 0 82 0 -8.2 0.1 -7.7 -8.6 12/11/2004 00:50:00 21.8 1.4 25.2 17.6 21.2 1.5 25.2 17.9 0.4 0 0.4 0.4 41 6 50 305 82 0 82 0 -8.2 0 -7.9 -8.4 12/11/2004 01:00:00 21 1.5 25.6 16.8 20.5 1.6 24.8 16.1 0.4 0 0.4 0.4 42 7 39 305 83 0 83 0 -7.8 0.1 -7.5 -8.2 12/11/2004 01:10:00 21.6 1.7 24.8 16.4 21 1.7 24 15.6 0.4 0 0.4 0.4 39 6 37 305 83 0 82 0 -7.6 0.1 -7.3 -7.9 12/11/2004 01:20:00 21.9 1.7 25.2 17.2 21.2 1.8 24.8 15.3 0.4 0 0.4 0.4 38 5 35 305 83 0 82 0 -7.6 0 -7.1 -7.7 12/11/2004 01:30:00 21.6 1.9 27.9 16.4 20.9 1.9 26.8 16.1 0.4 0 0.4 0.4 35 5 40 305 83 0 83 0 -7.6 0 -7.3 -7.7 12/11/2004 01:40:00 22.5 1.7 26.8 17.2 21.8 1.8 26.3 17.2 0.4 0 0.4 0.4 37 5 38 305 83 0 83 0 -7.7 0 -7.3 -7.7 12/11/2004 01:50:00 23.1 1.5 26.3 19.1 22.3 1.5 25.6 17.6 0.4 0 0.4 0.4 35 5 29 305 83 0 83 0 -7.6 0.1 -7.1 -7.7 12/11/2004 02:00:00 23.2 1.5 26.3 17.9 22.4 1.7 26 17.6 0.4 0 0.4 0.4 41 5 46 305 83 0 83 0 -7.4 0 -7.1 -7.5 12/11/2004 02:10:00 22.9 1.5 26 18.3 22.3 1.7 25.2 17.2 0.4 0 0.4 0.4 39 5 42 305 83 0 83 0 -7.2 0 -6.9 -7.5 12/11/2004 02:20:00 22.6 1.5 26.3 17.9 21.9 1.7 26 17.6 0.4 0 0.4 0.4 39 4 39 305 83 0 83 0 -7.1 0 -6.9 -7.3 12/11/2004 02:30:00 22.6 1.9 26.3 17.2 22 2.1 26 16.8 0.4 0 0.4 0.4 37 5 34 305 83 0 83 0 -7.2 0 -6.9 -7.3 12/11/2004 02:40:00 22.8 1.9 26.3 16.8 22.1 1.9 26 17.2 0.4 0 0.4 0.4 37 5 42 305 83 0 83 0 -7.1 0 -6.9 -7.3 12/11/2004 02:50:00 22.6 1.9 26.8 17.6 21.8 2 26.8 16.1 0.4 0 0.4 0.4 33 5 40 305 83 0 83 0 -7.1 0 -6.7 -7.3 12/11/2004 03:00:00 23.2 1.7 26.3 18.7 22.4 1.7 26 17.6 0.4 0 0.4 0.4 32 5 33 305 83 0 83 0 -7.1 0 -6.9 -7.3 12/11/2004 03:10:00 21.5 1.6 26 17.2 20.9 1.7 25.6 17.2 0.4 0 0.4 0.4 29 6 36 305 83 0 83 0 -7.2 0.2 -6.9 -7.7 12/11/2004 03:20:00 23 1.7 26.3 16.1 22.5 1.8 26.3 16.4 0.4 0 0.4 0.4 23 4 27 305 83 0 83 0 -7.8 0.2 -7.3 -8.2 12/11/2004 03:30:00 23.2 1.7 27.1 19.5 22.8 1.8 26.8 17.6 0.4 0 0.4 0.4 23 4 24 305 83 0 82 0 -8.2 0 -7.9 -8.4 12/11/2004 03:40:00 24.1 1.8 27.5 18.7 23.6 1.9 27.5 18.7 0.4 0 0.4 0.4 23 4 18 305 82 0 82 0 -8.4 0 -7.9 -8.6 12/11/2004 03:50:00 24.2 1.7 27.9 18.3 23.6 1.8 27.5 18.3 0.4 0 0.4 0.4 25 4 25 305 82 0 82 0 -8.5 0 -8.2 -8.8 12/11/2004 04:00:00 23.4 1.8 27.5 17.9 22.9 1.9 27.5 18.3 0.4 0 0.4 0.4 24 5 27 305 82 0 82 0 -8.5 0.1 -8.2 -8.8 12/11/2004 04:10:00 23.4 1.7 27.1 18.3 22.7 1.8 27.1 17.6 0.4 0 0.4 0.4 26 5 29 305 82 0 82 0 -8.4 0 -8.2 -8.6 12/11/2004 04:20:00 23.8 1.7 27.5 18.7 23.2 1.9 27.1 18.3 0.4 0 0.4 0.4 26 5 23 305 82 0 82 0 -8.5 0.1 -8.2 -8.8 12/11/2004 04:30:00 23.8 2 27.9 18.3 23.1 2.1 27.5 17.6 0.4 0 0.4 0.4 25 5 24 305 82 0 82 0 -8.5 0.1 -8.2 -8.8 12/11/2004 04:40:00 23.3 2.1 28.3 17.6 22.6 2.4 28.7 16.1 0.4 0 0.4 0.4 25 6 30 305 82 0 82 0 -8.3 0.1 -7.9 -8.6 12/11/2004 04:50:00 23.2 2.2 28.7 18.7 22.6 2.3 28.3 16.8 0.4 0 0.4 0.4 25 5 27 305 82 0 82 0 -8.4 0.1 -8.2 -8.8 12/11/2004 05:00:00 23.2 2.2 28.3 15.6 22.7 2.2 27.9 16.4 0.4 0 0.4 0.4 24 5 18 305 82 0 82 0 -8.4 0 -8.2 -8.6 12/11/2004 05:10:00 24.5 1.7 28.7 19.5 23.9 1.8 27.9 18.3 0.4 0 0.4 0.4 22 4 20 305 82 0 82 0 -8.5 0.1 -8.2 -8.8 12/11/2004 05:20:00 23.8 1.8 28.3 17.9 23.3 1.9 28.7 16.8 0.4 0 0.4 0.4 21 5 17 305 81 0 82 0 -8.6 0 -8.4 -8.8 12/11/2004 05:30:00 24.1 1.8 27.5 18.3 23.7 1.9 27.5 18.3 0.4 0 0.4 0.4 22 5 22 305 81 0 82 0 -8.6 0 -8.2 -8.8 12/11/2004 05:40:00 23.9 2 27.9 19.1 23.2 2 28.3 18.3 0.4 0 0.4 0.4 21 5 17 305 81 0 82 0 -8.7 0 -8.4 -8.8 12/11/2004 05:50:00 23.6 2 28.3 17.9 23.1 2.2 27.9 16.8 0.4 0 0.4 0.4 19 5 17 305 81 0 82 0 -8.8 0.1 -8.4 -9.2 12/11/2004 06:00:00 23.8 2.2 28.7 17.6 23.3 2.2 28.7 17.9 0.4 0 0.4 0.4 20 5 22 305 81 0 81 0 -9.1 0.1 -8.8 -9.2 12/11/2004 06:10:00 24.3 2.1 28.3 17.9 23.7 2.3 28.3 16.8 0.4 0 0.4 0.4 23 5 17 305 81 0 81 0 -9.1 0.1 -8.8 -9.2 12/11/2004 06:20:00 23.7 2.1 28.3 18.7 23.5 2.2 28.3 17.9 0.4 0 0.4 0.4 21 5 21 305 81 0 81 0 -9.1 0.1 -8.8 -9.6 12/11/2004 06:30:00 24.5 2.2 29.4 17.2 24 2.2 29.1 17.6 0.4 0 0.4 0.4 20 5 17 305 80 0 81 0 -9.4 0 -9.2 -9.6 12/11/2004 06:40:00 24.4 1.9 27.9 19.9 24 2 28.3 18.3 0.4 0 0.4 0.4 20 5 17 305 80 0 81 0 -9.4 0 -9.2 -9.6 12/11/2004 06:50:00 24.4 2.1 28.7 17.6 24 2.2 29.1 18.3 0.4 0 0.4 0.4 21 5 19 305 80 0 80 0 -9.5 0 -9.2 -9.6 12/11/2004 07:00:00 24.3 1.8 28.3 18.7 23.9 1.9 27.9 18.7 0.4 0 0.4 0.4 21 5 14 305 80 0 80 0 -9.4 0 -9.2 -9.8 12/11/2004 07:10:00 24.3 1.8 28.3 18.7 24.1 1.9 28.3 17.9 0.4 0 0.4 0.4 21 5 16 305 80 0 80 0 -9.7 0.1 -9.2 -10 12/11/2004 07:20:00 24.1 1.9 28.3 19.5 23.7 2 28.7 18.3 0.4 0 0.4 0.4 21 5 20 305 80 0 80 0 -9.9 0 -9.6 -10.2 12/11/2004 07:30:00 24.5 2 29.1 18.3 24.3 2.1 29.1 18.3 0.4 0 0.4 0.4 21 5 25 305 79 0 79 0 -10.1 0.1 -9.8 -10.4 12/11/2004 07:40:00 24.4 2 28.7 18.3 24 2.1 29.1 18.3 0.4 0 0.4 0.4 21 5 15 305 79 0 79 0 -10.2 0.1 -9.8 -10.4 12/11/2004 07:50:00 25.1 1.7 28.7 20.2 24.9 1.7 28.7 19.1 0.4 0 0.4 0.4 19 5 19 305 79 0 79 0 -10.5 0.1 -10 -10.9 12/11/2004 08:00:00 24.9 1.8 28.7 19.9 24.8 1.8 29.1 20.2 0.4 0 0.4 0.4 20 5 16 305 79 0 79 0 -10.8 0.1 -10.4 -11.1 12/11/2004 08:10:00 24.8 1.9 28.7 19.1 24.6 1.9 28.7 19.1 0.4 0 0.4 0.4 21 5 21 305 78 0 79 0 -10.9 0 -10.4 -11.3 12/11/2004 08:20:00 24.8 2.4 30.2 17.2 24.5 2.4 30.2 17.9 0.4 0 0.4 0.4 22 5 17 305 78 0 79 0 -11 0.1 -10.7 -11.3 12/11/2004 08:30:00 24.6 2 29.4 19.1 24.2 2.2 30.2 18.3 0.4 0 0.4 0.4 20 5 19 305 78 0 79 0 -11.1 0.1 -10.7 -11.5 12/11/2004 08:40:00 24.1 2.1 29.4 18.3 23.7 2.2 28.7 18.3 0.4 0 0.4 0.4 23 5 21 305 78 0 78 0 -11.1 0 -10.9 -11.5 12/11/2004 08:50:00 25.7 1.7 29.4 19.9 25.3 1.8 29.4 20.2 0.4 0 0.4 0.4 23 5 23 305 78 0 78 0 -11.5 0.1 -10.9 -11.9 12/11/2004 09:00:00 25.1 2.2 30.6 19.1 24.8 2.3 30.6 17.9 0.4 0 0.4 0.4 22 5 22 305 78 0 78 0 -11.7 0 -11.5 -11.9 12/11/2004 09:10:00 25.3 2 29.4 19.5 24.9 2.2 29.4 17.9 0.4 0 0.4 0.4 23 5 23 305 77 0 77 0 -11.8 0.1 -11.5 -12.1 12/11/2004 09:20:00 24.9 2.6 29.8 17.2 24.7 2.6 29.1 17.6 0.4 0 0.4 0.4 21 5 21 305 77 0 78 0 -11.8 0.1 -11.5 -12.1 12/11/2004 09:30:00 25.3 2 30.2 19.1 24.8 2 30.2 19.5 0.4 0 0.4 0.4 19 5 16 305 78 0 78 0 -11.8 0.1 -11.5 -12.1 12/11/2004 09:40:00 23.9 2.1 29.4 18.3 23.6 2.1 30.6 18.7 0.4 0 0.4 0.4 22 6 19 305 78 0 78 0 -11.8 0.1 -11.5 -12.1 12/11/2004 09:50:00 24.3 2.1 29.1 18.7 24 2.3 29.1 17.9 0.4 0 0.4 0.4 24 5 27 305 78 0 79 0 -11.9 0.1 -11.5 -12.1 12/11/2004 10:00:00 25.2 1.9 29.8 19.9 24.7 1.9 29.4 19.9 0.4 0 0.4 0.4 21 5 24 305 78 0 78 0 -12.1 0 -11.7 -12.3 12/11/2004 10:10:00 25.5 2.1 29.4 19.1 25.4 2.1 30.6 19.9 0.4 0 0.4 0.4 22 5 27 305 78 0 78 0 -12.2 0 -12.1 -12.5 12/11/2004 10:20:00 24.3 2.2 29.1 17.6 23.9 2.2 28.7 17.2 0.4 0 0.4 0.4 24 6 22 305 78 0 78 0 -12.1 0.1 -11.9 -12.5 12/11/2004 10:30:00 23.4 2.2 27.9 17.6 23 2.3 28.3 17.2 0.4 0 0.4 0.4 24 6 31 305 78 0 78 0 -12 0.1 -11.7 -12.3 12/11/2004 10:40:00 24 2.3 29.4 18.3 23.6 2.4 29.4 17.6 0.4 0 0.4 0.4 25 6 21 305 78 0 78 0 -12 0 -11.7 -12.3 12/11/2004 10:50:00 24.7 2 28.7 18.3 24.3 2.1 28.3 18.7 0.4 0 0.4 0.4 25 5 17 305 77 0 78 0 -12.4 0.1 -12.1 -12.5 12/11/2004 11:00:00 26 1.9 30.2 21 25.6 2 29.8 18.7 0.4 0 0.4 0.4 25 5 24 305 77 0 77 0 -12.5 0 -12.3 -12.5 12/11/2004 11:10:00 25.3 1.9 29.8 20.2 24.9 2 29.4 18.3 0.4 0 0.4 0.4 27 5 27 305 77 0 77 0 -12.5 0 -12.3 -12.7 12/11/2004 11:20:00 24.9 1.9 29.4 19.1 24.7 2.1 29.1 19.5 0.4 0 0.4 0.4 25 5 30 305 77 0 77 0 -12.5 0 -12.3 -12.7 12/11/2004 11:30:00 24.2 2 28.3 17.9 23.7 2.2 28.7 17.2 0.4 0 0.4 0.4 22 5 22 305 77 0 77 0 -12.5 0.2 -12.1 -12.9 12/11/2004 11:40:00 25.1 2.2 29.8 19.1 24.7 2.3 29.4 17.9 0.4 0 0.4 0.4 23 5 18 305 77 0 77 0 -12.7 0 -12.5 -12.9 12/11/2004 11:50:00 23.4 1.8 26.8 18.3 23 2 27.1 16.8 0.4 0 0.4 0.4 23 5 24 305 77 0 77 0 -12.7 0 -12.5 -12.9 12/11/2004 12:00:00 24 1.8 28.3 19.1 23.9 2 28.3 18.3 0.4 0 0.4 0.4 23 5 19 305 76 0 76 0 -12.8 0.1 -12.5 -13.1 12/11/2004 12:10:00 24.1 2.1 27.9 18.3 23.8 2.1 27.9 18.3 0.4 0 0.4 0.4 23 4 16 305 76 0 77 0 -12.9 0 -12.7 -13.1 12/11/2004 12:20:00 24 1.7 27.9 19.5 23.7 1.9 28.3 18.7 0.4 0 0.4 0.4 23 5 24 305 76 0 76 0 -13.1 0 -12.9 -13.3 12/11/2004 12:30:00 23.5 1.6 26.8 18.7 23.2 1.7 26.8 17.6 0.4 0 0.4 0.4 24 6 21 305 76 0 75 0 -13.1 0.1 -12.9 -13.3 12/11/2004 12:40:00 23.7 1.7 27.5 18.7 23.3 1.8 28.3 17.9 0.4 0 0.4 0.4 21 4 19 305 76 0 76 0 -13.1 0 -12.9 -13.3 12/11/2004 12:50:00 22.8 1.7 27.1 16.1 22.7 1.8 27.1 17.2 0.4 0 0.4 0.4 21 6 18 305 76 0 76 0 -13.1 0 -12.7 -13.3 12/11/2004 13:00:00 23.4 1.9 27.1 17.2 23.2 2 27.5 16.1 0.4 0 0.4 0.4 20 5 16 305 76 0 76 0 -13.1 0 -12.9 -13.3 12/11/2004 13:10:00 23.4 1.8 27.5 16.4 23.1 2.1 28.3 16.8 0.4 0 0.4 0.4 23 5 22 305 75 0 76 0 -13.2 0.1 -12.9 -13.5 12/11/2004 13:20:00 23.2 1.5 27.5 18.3 23 1.7 27.1 18.3 0.4 0 0.4 0.4 21 5 20 305 76 0 76 0 -13 0 -12.9 -13.3 12/11/2004 13:30:00 23.5 1.9 27.5 17.9 23.2 2 27.5 17.9 0.4 0 0.4 0.4 19 4 20 305 75 0 76 0 -13.1 0.1 -12.9 -13.3 12/11/2004 13:40:00 23.7 1.7 27.1 19.1 23.4 1.8 27.9 18.3 0.4 0 0.4 0.4 20 5 22 305 75 0 75 0 -13.2 0 -12.9 -13.5 12/11/2004 13:50:00 24.3 1.7 28.3 18.7 24.1 1.9 28.7 18.3 0.4 0 0.4 0.4 18 4 15 305 75 0 75 0 -13.4 0 -13.3 -13.5 12/11/2004 14:00:00 23 2 27.5 16.4 22.6 2.2 27.9 16.1 0.4 0 0.4 0.4 20 6 21 305 75 0 75 0 -13.2 0.1 -12.9 -13.7 12/11/2004 14:10:00 24.7 2 28.3 19.1 24.3 2.1 28.3 19.1 0.4 0 0.4 0.4 21 4 18 305 75 0 74 0 -13.4 0 -13.1 -13.7 12/11/2004 14:20:00 24.1 2.1 28.3 16.8 23.7 2.3 28.7 17.2 0.4 0 0.4 0.4 22 5 21 305 74 0 74 0 -13.4 0.1 -13.1 -13.7 12/11/2004 14:30:00 24 2 28.7 19.1 23.7 2.1 29.4 18.7 0.4 0 0.4 0.4 20 5 24 305 75 0 74 0 -13.3 0.1 -13.1 -13.7 12/11/2004 14:40:00 23.4 1.9 27.1 18.7 23.1 2 27.9 18.3 0.4 0 0.4 0.4 20 5 21 305 75 0 75 0 -13.3 0.1 -13.1 -13.7 12/11/2004 14:50:00 24.9 1.6 28.3 19.9 24.5 1.8 28.3 19.1 0.4 0 0.4 0.4 20 5 17 305 74 0 75 0 -13.5 0.1 -13.1 -13.7 12/11/2004 15:00:00 23.9 2 27.9 18.3 23.6 2.2 27.9 17.9 0.4 0 0.4 0.4 21 5 21 305 74 0 74 0 -13.5 0 -13.3 -13.7 12/11/2004 15:10:00 23.1 1.7 27.1 17.9 22.8 1.8 27.1 17.9 0.4 0 0.4 0.4 21 5 12 305 74 0 74 0 -13.4 0 -13.1 -13.7 12/11/2004 15:20:00 23.8 2.1 28.7 17.6 23.4 2.2 28.7 18.3 0.4 0 0.4 0.4 22 6 21 305 74 0 74 0 -13.4 0.1 -13.1 -13.7 12/11/2004 15:30:00 24.2 1.8 27.9 17.9 23.8 1.9 27.9 16.8 0.4 0 0.4 0.4 22 5 12 305 74 0 74 0 -13.5 0.1 -13.1 -13.7 12/11/2004 15:40:00 24 2.2 28.3 17.9 23.6 2.3 27.9 17.9 0.4 0 0.4 0.4 23 5 24 305 74 0 74 0 -13.6 0 -13.3 -13.7 12/11/2004 15:50:00 23.9 1.8 27.5 18.7 23.4 2.1 27.9 18.3 0.4 0 0.4 0.4 21 4 21 305 74 0 73 0 -13.7 0.1 -13.3 -13.9 12/11/2004 16:00:00 23.2 1.7 26.8 17.9 22.8 1.9 26.3 15.3 0.4 0 0.4 0.4 22 5 30 305 74 0 74 0 -13.5 0.1 -13.3 -13.7 12/11/2004 16:10:00 24.2 1.6 27.9 18.7 23.9 1.7 27.9 19.1 0.4 0 0.4 0.4 22 5 26 305 73 0 73 0 -13.8 0 -13.5 -14.1 12/11/2004 16:20:00 23.6 1.7 27.9 18.7 23.2 2 27.9 18.7 0.4 0 0.4 0.4 22 5 20 305 73 0 74 0 -13.8 0 -13.7 -14.1 12/11/2004 16:30:00 24 2 28.7 18.7 23.6 2.1 29.1 19.1 0.4 0 0.4 0.4 22 5 22 305 74 0 74 0 -13.6 0 -13.3 -13.7 12/11/2004 16:40:00 24.5 1.9 29.4 19.1 23.9 1.8 28.3 18.3 0.4 0 0.4 0.4 26 5 25 305 73 0 73 0 -13.7 0.1 -13.5 -14.1 12/11/2004 16:50:00 24.7 1.8 28.7 18.3 24.1 1.9 27.9 17.6 0.4 0 0.4 0.4 29 5 25 305 73 0 73 0 -13.7 0 -13.7 -13.9 12/11/2004 17:00:00 23.6 1.9 27.5 17.9 23 2 26.8 17.9 0.4 0 0.4 0.4 31 5 32 305 73 0 73 0 -13.6 0.1 -13.3 -13.7 12/11/2004 17:10:00 23.3 2.4 28.3 16.8 22.6 2.5 27.5 16.4 0.4 0 0.4 0.4 27 6 23 305 73 0 73 0 -13.5 0.1 -13.3 -13.7 12/11/2004 17:20:00 23.5 1.9 28.3 18.3 23 2.1 27.9 17.6 0.4 0 0.4 0.4 28 7 32 305 73 0 73 0 -13.6 0.1 -13.3 -13.9 12/11/2004 17:30:00 23.7 1.8 28.7 19.5 23.1 2 27.9 17.2 0.4 0 0.4 0.4 27 5 31 305 72 0 72 0 -13.9 0 -13.7 -14.1 12/11/2004 17:40:00 23.1 1.9 26.8 18.7 22.7 2 26.8 17.2 0.4 0 0.4 0.4 28 6 35 305 72 0 72 0 -14 0 -13.7 -14.3 12/11/2004 17:50:00 22.5 1.7 27.5 16.4 22.1 1.8 27.9 16.8 0.4 0 0.4 0.4 27 6 22 305 72 0 72 0 -14 0.1 -13.7 -14.3 12/11/2004 18:00:00 22.3 1.9 26.3 17.6 22 2.1 26.3 16.4 0.4 0 0.4 0.4 24 6 13 305 72 0 72 0 -14 0.1 -13.7 -14.3 12/11/2004 18:10:00 23 1.6 26 18.3 22.7 1.8 27.1 17.2 0.4 0 0.4 0.4 23 5 27 305 71 0 72 0 -14.2 0.1 -13.9 -14.6 12/11/2004 18:20:00 22.2 1.7 27.1 17.9 22 1.8 27.1 17.2 0.4 0 0.4 0.4 21 4 17 305 71 0 72 0 -14.2 0 -14.1 -14.4 12/11/2004 18:30:00 23.7 1.7 27.5 18.7 23.5 1.8 27.9 18.3 0.4 0 0.4 0.4 23 7 26 305 71 0 71 0 -14.4 0.1 -14.1 -14.6 12/11/2004 18:40:00 22.9 1.5 27.1 17.6 22.6 1.7 26.8 17.9 0.4 0 0.4 0.4 20 5 18 305 71 0 71 0 -14.5 0 -14.3 -14.6 12/11/2004 18:50:00 22.6 1.5 26 17.6 22.6 1.6 26 17.9 0.4 0 0.4 0.4 20 5 19 305 71 0 71 0 -14.5 0 -14.3 -14.6 12/11/2004 19:00:00 22.7 1.8 26.8 17.9 22.5 2 27.5 17.6 0.4 0 0.4 0.4 21 5 12 305 71 0 71 0 -14.5 0.1 -14.3 -14.6 12/11/2004 19:10:00 22.8 1.5 26 17.9 22.7 1.7 26.3 16.8 0.4 0 0.4 0.4 22 5 26 305 71 0 70 0 -14.4 0.2 -14.3 -14.6 12/11/2004 19:20:00 22.3 2.1 27.5 16.8 22.1 2.1 27.9 16.8 0.4 0 0.4 0.4 21 6 16 305 71 0 71 0 -14.4 0.1 -14.3 -14.6 12/11/2004 19:30:00 22.4 1.9 27.5 17.6 22.3 2 27.1 16.1 0.4 0 0.4 0.4 22 6 26 305 71 0 71 0 -14.4 0 -14.3 -14.6 12/11/2004 19:40:00 23.5 1.5 26.3 17.9 23.4 1.7 26.8 17.2 0.4 0 0.4 0.4 18 4 16 305 71 0 71 0 -14.6 0.1 -14.3 -14.6 12/11/2004 19:50:00 22.8 1.9 27.5 17.9 22.6 2.1 27.1 16.8 0.4 0 0.4 0.4 21 5 25 305 70 0 71 0 -14.5 0.1 -14.3 -14.6 12/11/2004 20:00:00 23 2.4 27.5 16.8 22.8 2.7 27.5 15.6 0.4 0 0.4 0.4 21 5 22 305 70 0 70 0 -14.6 0.1 -14.3 -14.8 12/11/2004 20:10:00 23.2 1.5 27.1 19.5 23.1 1.6 27.1 18.3 0.4 0 0.4 0.4 22 5 19 305 70 0 70 0 -14.5 0.1 -14.3 -14.6 12/11/2004 20:20:00 23 1.7 26.8 17.2 22.8 1.8 27.1 16.8 0.4 0 0.4 0.4 21 5 18 305 70 0 70 0 -14.6 0 -14.3 -14.6 12/11/2004 20:30:00 23.5 1.5 27.5 19.1 23.4 1.6 27.5 18.7 0.4 0 0.4 0.4 22 5 31 305 70 0 70 0 -14.6 0 -14.4 -14.6 12/11/2004 20:40:00 23 1.5 27.1 17.9 22.9 1.6 27.1 18.3 0.4 0 0.4 0.4 21 5 26 305 70 0 70 0 -14.5 0.1 -14.3 -14.6 12/11/2004 20:50:00 22.7 1.7 26.3 16.4 22.6 1.9 27.1 16.4 0.4 0 0.4 0.4 22 5 22 305 70 0 70 0 -14.5 0 -14.3 -14.6 12/11/2004 21:00:00 23.1 1.6 27.1 18.7 23.1 1.6 27.1 18.3 0.4 0 0.4 0.4 23 4 16 305 70 0 70 0 -14.4 0.1 -14.3 -14.6 12/11/2004 21:10:00 23.7 1.7 27.5 17.9 23.5 1.9 28.3 18.3 0.4 0 0.4 0.4 23 5 24 305 70 0 70 0 -14.4 0.1 -14.1 -14.6 12/11/2004 21:20:00 22.9 1.7 27.1 17.9 22.9 1.7 26.3 18.3 0.4 0 0.4 0.4 22 5 25 305 70 0 70 0 -14.5 0.2 -14.3 -14.8 12/11/2004 21:30:00 23.5 1.5 27.9 19.1 23.4 1.7 28.7 18.3 0.4 0 0.4 0.4 22 5 21 305 70 0 70 0 -14.6 0.1 -13.7 -14.6 12/11/2004 21:40:00 22.7 1.5 26.3 18.3 22.6 1.7 26.3 17.9 0.4 0 0.4 0.4 21 5 13 305 70 0 70 0 -14.6 0.1 -14.3 -14.6 12/11/2004 21:50:00 23.4 1.5 26.8 19.5 23.2 1.5 27.5 19.1 0.4 0 0.4 0.4 23 6 31 305 70 0 69 0 -14.7 0 -14.1 -14.6 12/11/2004 22:00:00 23.6 2.1 27.9 17.6 23.2 2 27.5 18.3 0.4 0 0.4 0.4 28 5 24 305 70 0 69 0 -14.5 0.1 -14.3 -14.6 12/11/2004 22:10:00 22.7 1.9 27.5 17.2 22.5 2.1 27.1 16.4 0.4 0 0.4 0.4 28 5 30 305 69 0 69 0 -14.6 0.1 -14.3 -14.8 12/11/2004 22:20:00 23 1.6 26.8 19.1 22.7 1.7 27.1 17.6 0.4 0 0.4 0.4 26 5 26 305 69 0 69 0 -14.7 0 -14.4 -14.8 12/11/2004 22:30:00 22.7 1.5 26 18.7 22.4 1.7 26.3 18.3 0.4 0 0.4 0.4 24 5 28 305 69 0 69 0 -14.7 0 -14.4 -15 12/11/2004 22:40:00 23.1 1.7 26.8 18.3 22.8 1.9 27.5 17.9 0.4 0 0.4 0.4 26 5 27 305 69 0 69 0 -14.7 0 -14.4 -14.8 12/11/2004 22:50:00 22.8 1.5 26.3 18.7 22.5 1.7 26.8 17.2 0.4 0 0.4 0.4 25 5 24 305 69 0 69 0 -14.8 0.1 -14.4 -15 12/11/2004 23:00:00 24.5 1.5 30.9 21.4 24.2 1.5 30.6 20.2 0.4 0 0.4 0.4 28 5 34 305 69 0 69 0 -14.8 0 -14.4 -15 12/11/2004 23:10:00 24.7 1.2 28.3 20.2 24.6 1.3 27.5 20.2 0.4 0 0.4 0.4 22 4 21 305 69 0 69 0 -14.9 0 -14.6 -15 12/11/2004 23:20:00 23.9 1.7 27.5 18.3 23.6 1.8 27.9 18.3 0.4 0 0.4 0.4 28 6 21 305 70 0 69 0 -14.5 0.2 -14.1 -15 12/11/2004 23:30:00 25.2 1.5 28.7 20.2 25 1.5 29.4 20.6 0.4 0 0.4 0.4 26 4 30 305 70 0 69 0 -14.7 0 -14.4 -14.8 12/11/2004 23:40:00 25.1 1.7 28.7 19.1 24.9 1.7 28.7 19.1 0.4 0 0.4 0.4 28 5 32 305 70 0 69 0 -14.8 0 -14.4 -15 12/11/2004 23:50:00 25.5 1.5 28.7 19.5 25.5 1.7 29.1 19.9 0.4 0 0.4 0.4 23 4 18 305 69 0 70 0 -15 0 -14.8 -15 12/12/2004 00:00:00 25.6 1.7 29.8 20.2 25.5 1.8 30.6 19.5 0.4 0 0.4 0.4 23 4 20 305 69 0 69 0 -15 0.1 -14.4 -15.2 12/12/2004 00:10:00 25.1 1.5 29.4 20.2 24.8 1.6 28.7 20.2 0.4 0 0.4 0.4 27 6 31 305 70 0 69 0 -14.8 0 -14.3 -15 12/12/2004 00:20:00 25.8 1.7 29.1 20.6 25.5 1.8 29.1 19.5 0.4 0 0.4 0.4 29 5 26 305 70 0 70 0 -14.8 0.1 -14.3 -15 12/12/2004 00:30:00 26.4 1.7 30.6 21.8 26.1 1.9 30.9 20.2 0.4 0 0.4 0.4 23 4 21 305 70 0 70 0 -15.1 0.1 -14.6 -15.2 12/12/2004 00:40:00 26.4 1.7 30.2 19.9 26.3 1.9 30.2 20.2 0.4 0 0.4 0.4 23 4 21 305 70 0 69 0 -15.1 0.1 -14.6 -15.4 12/12/2004 00:50:00 24.8 2.1 29.4 18.7 24.5 2.3 29.4 19.1 0.4 0 0.4 0.4 27 6 22 305 70 0 69 0 -14.9 0.1 -14.3 -15.2 12/12/2004 01:00:00 24.7 1.6 28.3 20.2 24.5 1.9 28.3 19.1 0.4 0 0.4 0.4 24 5 24 305 70 0 70 0 -14.9 0 -14.4 -15 12/12/2004 01:10:00 23.6 1.7 28.3 18.3 23.3 1.8 27.5 17.6 0.4 0 0.4 0.4 30 4 30 305 70 0 69 0 -15.1 0.1 -14.8 -15.2 12/12/2004 01:20:00 24.2 1.7 27.9 18.3 24.2 1.7 28.7 18.7 0.4 0 0.4 0.4 24 4 26 305 70 0 69 0 -15.3 0.1 -15 -15.6 12/12/2004 01:30:00 23.2 1.9 27.1 16.1 23.1 2 27.1 16.8 0.4 0 0.4 0.4 26 5 27 305 69 0 69 0 -15.5 0.1 -14.8 -15.8 12/12/2004 01:40:00 23.8 1.5 27.1 19.1 23.8 1.5 27.5 19.9 0.4 0 0.4 0.4 26 6 24 305 69 0 70 0 -15.6 0.1 -15.2 -15.8 12/12/2004 01:50:00 23.4 1.7 26.8 17.6 23.2 1.7 27.5 18.7 0.4 0 0.4 0.4 28 7 30 305 69 0 69 0 -15.6 0 -15.2 -15.8 12/12/2004 02:00:00 23.2 2.3 28.7 17.6 23 2.4 28.7 16.8 0.4 0 0.4 0.4 28 6 29 305 70 0 70 0 -15.2 0 -15 -15.6 12/12/2004 02:10:00 24.6 1.3 27.5 21 24.7 1.4 28.3 21 0.4 0 0.4 0.4 28 4 32 305 70 0 69 0 -15.6 0.1 -15.2 -15.8 12/12/2004 02:20:00 22.9 1.4 27.5 18.7 22.8 1.6 26.3 18.3 0.4 0 0.4 0.4 28 5 20 305 70 0 70 0 -15.4 0.1 -15 -15.8 12/12/2004 02:30:00 22.9 1.5 26 17.9 22.8 1.6 26 17.9 0.4 0 0.4 0.4 26 6 25 305 70 0 70 0 -15.6 0.1 -15.2 -15.8 12/12/2004 02:40:00 22.8 1.5 27.1 17.9 22.7 1.7 27.1 17.6 0.4 0 0.4 0.4 26 6 27 305 70 0 70 0 -15.6 0.1 -15.2 -15.8 12/12/2004 02:50:00 22.7 1.6 26 16.8 22.5 1.7 26.3 15.3 0.4 0 0.4 0.4 29 6 31 305 70 0 70 0 -15.7 0 -15.4 -16 12/12/2004 03:00:00 22.6 1.6 28.3 17.2 22.4 1.7 27.9 17.9 0.4 0 0.4 0.4 27 5 24 305 70 0 70 0 -15.7 0.1 -15.4 -16 12/12/2004 03:10:00 23 1.2 26 19.5 23 1.3 26.3 18.7 0.4 0 0.4 0.4 26 5 20 305 69 0 70 0 -15.9 0 -15.8 -16.2 12/12/2004 03:20:00 23.1 1.5 26.8 19.1 23 1.5 27.9 19.1 0.4 0 0.4 0.4 27 5 32 305 69 0 69 0 -16 0 -15.8 -16.2 12/12/2004 03:30:00 22.1 1.7 25.2 17.9 22.1 1.8 25.6 17.9 0.4 0 0.4 0.4 26 6 22 305 69 0 70 0 -16 0.1 -15.6 -16.4 12/12/2004 03:40:00 22.1 1.3 25.6 17.2 22.2 1.5 25.6 16.4 0.4 0 0.4 0.4 26 7 25 305 69 0 69 0 -16 0.1 -15.6 -16.4 12/12/2004 03:50:00 22.7 1.4 25.2 18.3 22.8 1.6 25.6 18.7 0.4 0 0.4 0.4 22 6 21 305 70 0 70 0 -16 0.1 -15.8 -16.4 12/12/2004 04:00:00 22.4 1.5 25.6 17.6 22.4 1.7 26 17.6 0.4 0 0.4 0.4 25 5 21 305 70 0 70 0 -16 0.1 -15.4 -16.2 12/12/2004 04:10:00 23 1.4 26.3 19.1 23 1.5 27.1 16.8 0.4 0 0.4 0.4 32 5 31 305 70 0 70 0 -16.1 0.1 -15.6 -16.4 12/12/2004 04:20:00 23.3 1.3 26.3 19.9 23.2 1.4 26.8 19.1 0.4 0 0.4 0.4 32 3 40 305 70 0 70 0 -16.3 0 -15.8 -16.4 12/12/2004 04:30:00 22 1.8 26.8 17.2 22 1.8 27.5 17.6 0.4 0 0.4 0.4 30 6 31 305 70 0 71 0 -16.1 0.1 -15.4 -16.4 12/12/2004 04:40:00 21.1 1.4 24.8 17.9 21.2 1.5 24.8 17.2 0.4 0 0.4 0.4 27 6 24 305 71 0 71 0 -16 0.1 -15.2 -16.2 12/12/2004 04:50:00 21.5 1.4 25.6 17.2 21.5 1.6 26 17.6 0.4 0 0.4 0.4 29 6 25 305 71 0 71 0 -15.9 0.1 -15.6 -16.2 12/12/2004 05:00:00 22.4 1.5 25.6 17.6 22.5 1.7 26 17.9 0.4 0 0.4 0.4 26 5 25 305 71 0 71 0 -16.2 0.1 -16 -16.4 12/12/2004 05:10:00 22.3 1.6 26 17.6 22.3 1.7 26 17.6 0.4 0 0.4 0.4 28 5 33 305 71 0 71 0 -16.3 0.1 -16 -16.4 12/12/2004 05:20:00 23.1 1.3 26 18.7 23.2 1.6 27.1 18.3 0.4 0 0.4 0.4 27 5 26 305 71 0 71 0 -16.2 0.2 -15.8 -16.6 12/12/2004 05:30:00 21.9 1.7 26.3 17.2 22 1.8 26.8 17.6 0.4 0 0.4 0.4 27 6 22 305 71 0 71 0 -16.4 0.2 -16 -16.6 12/12/2004 05:40:00 22.3 1.5 26 18.3 22.4 1.5 26 18.3 0.4 0 0.4 0.4 27 5 25 305 71 0 71 0 -16.3 0.1 -16 -16.6 12/12/2004 05:50:00 22.1 1.6 26 17.2 22.4 1.7 26.3 17.2 0.4 0 0.4 0.4 27 5 22 305 71 0 71 0 -16.3 0 -15.8 -16.4 12/12/2004 06:00:00 21.9 1.5 25.6 16.8 22.1 1.5 26 17.6 0.4 0 0.4 0.4 26 5 25 305 71 0 72 0 -16.2 0.1 -16 -16.4 12/12/2004 06:10:00 21 1.8 24.8 16.1 21.1 1.9 24.8 16.4 0.4 0 0.4 0.4 28 4 29 305 71 0 71 0 -16.1 0.1 -15.8 -16.4 12/12/2004 06:20:00 22.5 1.7 26.3 17.6 22.5 1.7 26.3 17.6 0.4 0 0.4 0.4 32 5 29 305 71 0 71 0 -16.3 0 -16 -16.6 12/12/2004 06:30:00 20.4 1.8 24 15.6 20.4 2 25.2 14.5 0.4 0 0.4 0.4 29 5 31 305 72 0 72 0 -16 0.2 -15.8 -16.4 12/12/2004 06:40:00 20 1.7 24.8 14.1 20.1 1.9 25.2 16.1 0.4 0 0.4 0.4 29 6 23 305 72 0 72 0 -15.9 0 -15.8 -16 12/12/2004 06:50:00 21.3 1.5 24.8 16.1 21.3 1.7 26 16.4 0.4 0 0.4 0.4 28 5 25 305 72 0 72 0 -16.2 0.1 -15.8 -16.4 12/12/2004 07:00:00 20.9 1.8 25.2 16.4 21.1 1.8 25.6 15.3 0.4 0 0.4 0.4 26 5 27 305 72 0 72 0 -16.3 0.1 -16 -16.4 12/12/2004 07:10:00 20.9 1.2 23.7 17.2 21 1.4 24.4 16.8 0.4 0 0.4 0.4 25 5 21 305 71 0 72 0 -16.4 0 -16.2 -16.6 12/12/2004 07:20:00 19.4 1.7 22.6 13.7 19.4 1.9 22.9 13 0.4 0 0.4 0.4 30 6 26 305 72 0 72 0 -16.1 0.1 -15.8 -16.6 12/12/2004 07:30:00 20.6 1.6 24.4 15.3 20.7 1.8 25.2 15.6 0.4 0 0.4 0.4 24 5 25 305 72 0 72 0 -16.2 0.1 -16 -16.6 12/12/2004 07:40:00 20.5 1.4 23.7 16.8 20.7 1.6 24.4 16.1 0.4 0 0.4 0.4 23 5 33 305 72 0 72 0 -16.3 0 -16 -16.4 12/12/2004 07:50:00 20.6 1.5 24 16.1 20.7 1.7 24 15.3 0.4 0 0.4 0.4 25 6 31 305 72 0 72 0 -16.2 0.1 -16 -16.4 12/12/2004 08:00:00 20 1.4 23.3 15.3 20.1 1.5 23.7 14.9 0.4 0 0.4 0.4 23 5 25 305 72 0 72 0 -16.3 0 -16 -16.4 12/12/2004 08:10:00 20.2 1.7 24 15.6 20.1 1.9 24.4 14.9 0.4 0 0.4 0.4 27 5 32 305 72 0 72 0 -16.3 0 -16 -16.4 12/12/2004 08:20:00 20.9 1.5 24 16.8 20.9 1.6 24.4 16.4 0.4 0 0.4 0.4 28 5 25 305 71 0 72 0 -16.4 0 -16.2 -16.6 12/12/2004 08:30:00 20.1 1.7 23.3 14.9 20 1.8 24 14.9 0.4 0 0.4 0.4 26 6 25 305 71 0 72 0 -16.4 0 -15.8 -16.6 12/12/2004 08:40:00 20.4 1.7 23.7 15.3 20.3 1.7 23.3 15.3 0.4 0 0.4 0.4 26 6 22 305 72 0 72 0 -16.3 0 -16 -16.6 12/12/2004 08:50:00 18.9 1.7 23.3 14.5 18.8 1.7 23.7 14.5 0.4 0 0.4 0.4 23 6 17 305 72 0 72 0 -16.3 0 -16 -16.6 12/12/2004 09:00:00 19.6 1.6 23.7 15.3 19.7 1.7 24.4 14.5 0.4 0 0.4 0.4 20 5 16 305 71 0 72 0 -16.7 0.1 -16.4 -16.9 12/12/2004 09:10:00 19.5 1.4 22.1 14.9 19.6 1.5 22.6 14.9 0.4 0 0.4 0.4 23 6 21 305 71 0 71 0 -16.7 0.1 -16.4 -16.9 12/12/2004 09:20:00 19.5 1.5 22.9 15.3 19.7 1.5 24 15.6 0.4 0 0.4 0.4 24 5 20 305 71 0 71 0 -16.9 0 -16.4 -16.9 12/12/2004 09:30:00 19.8 1.4 23.3 15.6 20 1.4 23.3 16.1 0.4 0 0.4 0.4 21 6 21 305 71 0 71 0 -16.9 0 -16.4 -16.9 12/12/2004 09:40:00 19.4 1.6 23.7 14.9 19.5 1.7 23.7 15.3 0.4 0 0.4 0.4 23 5 26 305 71 0 71 0 -16.6 0.1 -16 -16.9 12/12/2004 09:50:00 19.9 1.5 23.7 15.3 19.9 1.7 24 15.6 0.4 0 0.4 0.4 29 6 34 305 71 0 71 0 -16.9 0 -16.4 -16.9 12/12/2004 10:00:00 19.8 1.5 23.7 15.6 19.8 1.6 24 15.3 0.4 0 0.4 0.4 29 5 33 305 71 0 71 0 -16.7 0.1 -16.6 -16.9 12/12/2004 10:10:00 19.7 1.6 22.9 15.3 19.7 1.7 23.3 15.3 0.4 0 0.4 0.4 25 6 21 305 71 0 72 0 -16.7 0.2 -16.4 -16.9 12/12/2004 10:20:00 19.3 1.5 22.9 15.3 19.2 1.6 22.9 13.7 0.4 0 0.4 0.4 27 6 28 305 71 0 71 0 -16.8 0 -16.6 -16.9 12/12/2004 10:30:00 19.9 1.3 22.6 16.1 19.7 1.5 22.9 15.3 0.4 0 0.4 0.4 24 7 25 305 71 0 71 0 -16.7 0.1 -16.6 -16.9 12/12/2004 10:40:00 19.8 1.5 23.3 15.3 19.8 1.7 24 15.3 0.4 0 0.4 0.4 23 5 23 305 70 0 71 0 -16.9 0 -16.6 -17.3 12/12/2004 10:50:00 19.4 1.5 22.6 15.6 19.3 1.7 22.9 15.3 0.4 0 0.4 0.4 27 7 14 305 70 0 71 0 -16.9 0 -16.6 -17.1 12/12/2004 11:00:00 19.4 1.2 22.6 15.6 19.5 1.3 22.9 15.6 0.4 0 0.4 0.4 28 6 30 305 70 0 71 0 -17 0 -16.9 -17.1 12/12/2004 11:10:00 19.3 1.7 22.6 15.3 19.3 1.7 22.9 14.9 0.4 0 0.4 0.4 21 6 28 305 71 0 70 0 -17 0 -16.9 -17.1 12/12/2004 11:20:00 19.6 1.5 23.7 15.6 19.4 1.7 23.7 15.3 0.4 0 0.4 0.4 24 6 27 305 71 0 71 0 -16.9 0 -16.6 -17.1 12/12/2004 11:30:00 19.3 1.5 23.3 15.3 19.1 1.7 23.7 14.9 0.4 0 0.4 0.4 23 7 16 305 71 0 71 0 -16.9 0 -16.9 -17.1 12/12/2004 11:40:00 20.1 1.3 23.3 15.6 20 1.5 23.7 15.6 0.4 0 0.4 0.4 22 5 27 305 71 0 71 0 -17 0 -16.9 -17.1 12/12/2004 11:50:00 20.3 1.5 24.4 15.3 20.1 1.7 24.4 14.9 0.4 0 0.4 0.4 21 5 21 305 70 0 71 0 -17.2 0 -16.9 -17.3 12/12/2004 12:00:00 19.8 1.7 24 13.7 19.5 1.8 23.7 13.7 0.4 0 0.4 0.4 27 6 22 305 70 0 71 0 -17.1 0 -16.9 -17.3 12/12/2004 12:10:00 20.1 1.5 24 16.1 19.9 1.6 23.7 15.3 0.4 0 0.4 0.4 25 6 26 305 70 0 71 0 -17.2 0.1 -16.9 -17.5 12/12/2004 12:20:00 20.1 1.5 24.8 15.6 19.8 1.6 23.3 15.6 0.4 0 0.4 0.4 26 6 29 305 70 0 70 0 -17.4 0 -17.1 -17.5 12/12/2004 12:30:00 20.3 1.4 23.3 16.1 20.1 1.7 23.7 15.3 0.4 0 0.4 0.4 24 6 19 305 70 0 70 0 -17.4 0 -17.3 -17.5 12/12/2004 12:40:00 20.2 1.8 23.3 14.9 19.9 1.8 23.3 15.6 0.4 0 0.4 0.4 26 7 32 305 70 0 70 0 -17.4 0.1 -16.9 -17.7 12/12/2004 12:50:00 20.3 1.5 23.7 16.1 20 1.5 24 16.1 0.4 0 0.4 0.4 24 6 28 305 70 0 70 0 -17.4 0 -17.1 -17.7 12/12/2004 13:00:00 20.1 1.3 22.9 16.1 19.9 1.5 23.3 16.4 0.4 0 0.4 0.4 26 5 30 305 70 0 70 0 -17.4 0 -16.9 -17.5 12/12/2004 13:10:00 20.5 1.4 23.7 17.2 20.3 1.5 24 16.4 0.4 0 0.4 0.4 29 6 31 305 70 0 70 0 -17.4 0 -16.9 -17.5 12/12/2004 13:20:00 20.5 1.6 24 14.1 20.4 1.7 23.7 14.9 0.4 0 0.4 0.4 23 5 27 305 70 0 70 0 -17.4 0 -16.9 -17.5 12/12/2004 13:30:00 20.6 1.5 23.7 16.4 20.5 1.7 24 16.4 0.4 0 0.4 0.4 27 5 29 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/12/2004 13:40:00 20.2 1.4 23.3 16.4 20 1.6 24 15.6 0.4 0 0.4 0.4 27 8 29 305 70 0 71 0 -17.3 0.1 -16.9 -17.5 12/12/2004 13:50:00 20 1.5 23.3 14.5 19.8 1.7 23.3 15.3 0.4 0 0.4 0.4 27 5 20 305 70 0 71 0 -17.4 0 -16.9 -17.5 12/12/2004 14:00:00 20.9 1.6 24 16.8 20.6 1.7 24 16.1 0.4 0 0.4 0.4 28 6 18 305 70 0 71 0 -17.4 0 -16.9 -17.5 12/12/2004 14:10:00 20.7 1.7 24.8 16.8 20.4 1.7 24.8 16.1 0.4 0 0.4 0.4 31 5 27 305 70 0 71 0 -17.3 0.1 -16.9 -17.5 12/12/2004 14:20:00 20.4 1.5 24 16.1 20.1 1.6 24 15.3 0.4 0 0.4 0.4 30 5 35 305 70 0 70 0 -17.4 0.1 -16.9 -17.5 12/12/2004 14:30:00 20.5 1.3 24.4 16.8 20.3 1.5 24 16.4 0.4 0 0.4 0.4 34 6 37 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/12/2004 14:40:00 20.9 1.5 23.7 16.1 20.5 1.5 23.7 15.3 0.4 0 0.4 0.4 37 6 44 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/12/2004 14:50:00 19.3 1.7 22.6 15.6 19.2 1.7 22.9 14.9 0.4 0 0.4 0.4 34 7 41 305 70 0 70 0 -17.4 0.1 -16.9 -17.7 12/12/2004 15:00:00 18.8 1.7 23.3 14.5 18.4 1.7 22.1 14.1 0.4 0 0.4 0.4 28 6 22 305 71 0 71 0 -17.2 0.1 -16.6 -17.5 12/12/2004 15:10:00 20.2 1.6 23.7 15.3 19.8 1.7 23.7 15.3 0.4 0 0.4 0.4 32 6 33 305 71 0 71 0 -17.3 0.1 -16.7 -17.5 12/12/2004 15:20:00 19.8 1.4 23.3 15.3 19.6 1.4 22.9 16.1 0.4 0 0.4 0.4 34 6 32 305 70 0 70 0 -17.5 0 -17.3 -17.5 12/12/2004 15:30:00 19 1.6 22.1 14.1 18.7 1.6 22.1 14.5 0.4 0 0.4 0.4 31 6 21 305 70 0 71 0 -17.3 0.1 -17.1 -17.5 12/12/2004 15:40:00 19.4 1.6 22.1 15.3 18.9 1.7 22.6 14.1 0.4 0 0.4 0.4 33 6 34 305 70 0 70 0 -17.4 0 -16.9 -17.5 12/12/2004 15:50:00 20 1.5 23.3 15.3 19.7 1.5 23.3 14.9 0.4 0 0.4 0.4 28 5 31 305 70 0 71 0 -17.5 0.1 -17.1 -17.7 12/12/2004 16:00:00 19.3 1.7 22.9 14.9 18.8 1.7 22.6 14.9 0.4 0 0.4 0.4 32 7 31 305 70 0 71 0 -17.5 0 -17.3 -17.7 12/12/2004 16:10:00 18.5 1.7 23.3 14.5 18.1 1.7 22.6 14.1 0.4 0 0.4 0.4 34 7 36 305 70 0 70 0 -17.3 0 -17.1 -17.5 12/12/2004 16:20:00 19.5 1.5 23.3 15.6 19.1 1.6 23.3 14.9 0.4 0 0.4 0.4 36 6 35 305 70 0 71 0 -17.5 0.1 -17.1 -17.7 12/12/2004 16:30:00 20.3 1.5 24 16.4 19.9 1.5 23.7 15.6 0.4 0 0.4 0.4 32 6 41 305 70 0 70 0 -17.6 0 -17.5 -17.7 12/12/2004 16:40:00 21.2 1.3 24.4 16.8 20.7 1.5 24.4 15.6 0.4 0 0.4 0.4 34 5 34 305 70 0 70 0 -17.7 0 -17.5 -17.9 12/12/2004 16:50:00 19.8 1.6 22.9 14.1 19.5 1.6 23.3 14.5 0.4 0 0.4 0.4 31 6 27 305 70 0 70 0 -17.7 0.1 -17.5 -18.1 12/12/2004 17:00:00 19.6 1.7 23.3 14.9 19.3 1.7 23.7 14.5 0.4 0 0.4 0.4 32 6 35 305 70 0 70 0 -17.6 0 -17.5 -17.9 12/12/2004 17:10:00 19.6 1.7 23.3 15.6 19.1 1.7 22.9 14.9 0.4 0 0.4 0.4 30 5 29 305 70 0 70 0 -17.7 0 -17.5 -17.9 12/12/2004 17:20:00 19.9 1.7 23.7 15.3 19.5 1.7 22.9 14.9 0.4 0 0.4 0.4 30 6 25 305 70 0 70 0 -17.7 0 -17.5 -17.9 12/12/2004 17:30:00 20 1.7 23.7 14.9 19.7 1.5 23.7 15.6 0.4 0 0.4 0.4 33 5 34 305 70 0 70 0 -17.7 0 -17.3 -17.9 12/12/2004 17:40:00 19.5 1.6 23.7 14.5 19.1 1.6 22.9 14.9 0.4 0 0.4 0.4 32 5 36 305 70 0 70 0 -17.7 0 -17.1 -17.9 12/12/2004 17:50:00 20.4 1.7 24 15.3 20 1.7 23.7 14.9 0.4 0 0.4 0.4 32 4 29 305 70 0 70 0 -17.7 0.1 -17.1 -18.1 12/12/2004 18:00:00 19.7 1.6 23.3 14.9 19.2 1.7 22.9 14.1 0.4 0 0.4 0.4 32 5 34 305 70 0 70 0 -17.8 0 -17.3 -18.1 12/12/2004 18:10:00 18.4 1.8 22.6 14.5 18 1.9 22.1 12.6 0.4 0 0.4 0.4 33 6 42 305 70 0 70 0 -17.5 0 -17.1 -17.7 12/12/2004 18:20:00 18.4 1.6 23.3 14.1 18.1 1.6 22.6 14.1 0.4 0 0.4 0.4 33 6 24 305 70 0 71 0 -17.5 0 -16.9 -17.5 12/12/2004 18:30:00 20.4 1.7 23.7 15.6 19.8 1.8 23.7 15.3 0.4 0 0.4 0.4 32 5 34 305 70 0 70 0 -17.7 0.1 -17.1 -17.9 12/12/2004 18:40:00 20.5 1.7 24.8 15.3 20 1.6 23.7 15.6 0.4 0 0.4 0.4 32 5 35 305 70 0 70 0 -17.7 0 -17.3 -17.9 12/12/2004 18:50:00 19.9 1.5 22.9 16.1 19.2 1.7 22.6 15.3 0.4 0 0.4 0.4 29 5 30 305 70 0 70 0 -17.7 0 -17.3 -17.9 12/12/2004 19:00:00 18.9 1.7 22.6 14.1 18.5 1.7 22.6 13.3 0.4 0 0.4 0.4 34 5 35 305 70 0 71 0 -17.6 0 -17.1 -17.9 12/12/2004 19:10:00 19.7 1.5 23.3 14.9 19.1 1.5 22.9 14.9 0.4 0 0.4 0.4 31 5 32 305 70 0 70 0 -17.6 0 -17.1 -17.7 12/12/2004 19:20:00 18.3 1.9 22.1 13.3 17.9 2 22.1 13 0.4 0 0.4 0.4 32 6 28 305 70 0 69 0 -17.6 0.1 -16.9 -17.9 12/12/2004 19:30:00 19.8 1.5 22.9 15.6 19.3 1.5 22.6 15.3 0.4 0 0.4 0.4 32 6 31 305 70 0 71 0 -17.6 0.1 -16.9 -17.9 12/12/2004 19:40:00 19.3 1.5 22.6 14.9 18.7 1.4 22.6 14.9 0.4 0 0.4 0.4 34 6 35 305 70 0 70 0 -17.6 0 -17.1 -17.9 12/12/2004 19:50:00 19.4 1.3 22.6 15.3 19 1.4 22.9 15.3 0.4 0 0.4 0.4 30 6 33 305 70 0 70 0 -17.6 0 -17.1 -17.7 12/12/2004 20:00:00 18.9 1.4 22.1 14.5 18.5 1.5 22.1 14.5 0.4 0 0.4 0.4 35 6 34 305 70 0 71 0 -17.5 0 -17.5 -17.7 12/12/2004 20:10:00 19.6 1.5 22.6 15.6 19.2 1.6 22.1 14.1 0.4 0 0.4 0.4 35 5 35 305 70 0 70 0 -17.6 0 -17.1 -17.7 12/12/2004 20:20:00 19.8 1.3 22.9 15.3 19.3 1.5 22.6 14.5 0.4 0 0.4 0.4 30 6 29 305 70 0 71 0 -17.6 0 -16.9 -17.7 12/12/2004 20:30:00 18.5 2.3 23.3 13.3 18.1 2.3 23.7 13.3 0.4 0 0.4 0.4 32 5 34 305 71 0 71 0 -17.5 0 -17.1 -17.7 12/12/2004 20:40:00 17.7 1.7 21.8 13.3 17.3 1.7 22.1 13.7 0.4 0 0.4 0.4 34 6 39 305 71 0 71 0 -17.4 0 -16.9 -17.5 12/12/2004 20:50:00 18.9 1.6 22.1 14.1 18.3 1.6 22.1 14.1 0.4 0 0.4 0.4 35 5 33 305 71 0 71 0 -17.4 0 -16.9 -17.5 12/12/2004 21:00:00 19.3 1.6 22.9 14.1 18.8 1.6 22.9 13.7 0.4 0 0.4 0.4 36 5 37 305 71 0 71 0 -17.5 0 -17.3 -17.5 12/12/2004 21:10:00 19 1.7 22.6 14.5 18.6 1.7 22.1 14.9 0.4 0 0.4 0.4 32 5 32 305 71 0 71 0 -17.4 0 -17.1 -17.5 12/12/2004 21:20:00 19.8 1.7 23.7 15.3 19.3 1.7 23.7 14.1 0.4 0 0.4 0.4 33 6 34 305 71 0 71 0 -17.5 0 -17.3 -17.5 12/12/2004 21:30:00 20.1 1.4 23.3 15.6 19.7 1.5 22.6 14.9 0.4 0 0.4 0.4 33 5 30 305 71 0 70 0 -17.5 0 -17.3 -17.5 12/12/2004 21:40:00 19.3 1.7 22.9 14.9 18.8 1.7 22.6 14.1 0.4 0 0.4 0.4 32 5 35 305 71 0 71 0 -17.4 0 -17.3 -17.5 12/12/2004 21:50:00 18.5 1.3 21.4 14.5 18 1.4 21.4 14.5 0.4 0 0.4 0.4 32 7 39 305 71 0 71 0 -17.3 0 -16.9 -17.5 12/12/2004 22:00:00 19.5 2.2 24 14.1 19.1 2.2 24 13.7 0.4 0 0.4 0.4 37 6 31 305 71 0 71 0 -17.2 0.1 -16.9 -17.5 12/12/2004 22:10:00 20.3 1.5 23.7 16.4 19.8 1.6 23.3 16.1 0.4 0 0.4 0.4 37 5 36 305 71 0 71 0 -17.4 0.1 -16.9 -17.5 12/12/2004 22:20:00 20.6 1.6 24 15.6 20.1 1.6 24.8 15.3 0.4 0 0.4 0.4 35 5 41 305 71 0 71 0 -17.4 0.1 -16.9 -17.5 12/12/2004 22:30:00 20 1.5 22.9 14.9 19.4 1.7 23.3 14.5 0.4 0 0.4 0.4 33 5 29 305 71 0 71 0 -17.4 0.1 -16.9 -17.5 12/12/2004 22:40:00 19.2 1.6 22.1 14.5 18.7 1.7 22.1 14.5 0.4 0 0.4 0.4 31 5 29 305 71 0 71 0 -17.3 0.1 -16.9 -17.5 12/12/2004 22:50:00 19.4 1.6 24 14.9 18.8 1.7 24 14.5 0.4 0 0.4 0.4 36 5 41 305 70 0 70 0 -17.4 0.1 -16.9 -17.5 12/12/2004 23:00:00 18.6 1.7 22.6 13.7 18.3 1.7 22.9 14.5 0.4 0 0.4 0.4 34 5 39 305 70 0 71 0 -17.4 0 -16.9 -17.5 12/12/2004 23:10:00 19.1 1.7 22.6 14.1 18.6 1.7 21.8 13.7 0.4 0 0.4 0.4 36 5 38 305 70 0 71 0 -17.5 0 -16.9 -17.5 12/12/2004 23:20:00 18.5 1.6 21.8 14.5 18.1 1.7 21.4 13.3 0.4 0 0.4 0.4 36 6 32 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/12/2004 23:30:00 18.1 1.7 21.4 14.1 17.7 1.7 21 13.7 0.4 0 0.4 0.4 35 6 33 305 70 0 70 0 -17.5 0 -16.9 -17.5 12/12/2004 23:40:00 19.1 1.6 22.6 15.3 18.5 1.7 22.1 14.9 0.4 0 0.4 0.4 30 5 41 305 71 0 71 0 -17.4 0 -16.9 -17.5 12/12/2004 23:50:00 18.6 1.8 22.1 14.5 18.1 1.9 21.8 13.3 0.4 0 0.4 0.4 32 6 41 305 71 0 71 0 -17.4 0 -16.9 -17.5 12/13/2004 00:00:00 18.7 1.6 22.9 14.5 18.2 1.7 22.6 13.3 0.4 0 0.4 0.4 33 6 35 305 70 0 70 0 -17.4 0 -16.9 -17.5 12/13/2004 00:10:00 19.3 1.7 22.6 14.9 18.8 1.7 22.6 14.5 0.4 0 0.4 0.4 34 5 23 305 70 0 71 0 -17.5 0 -17.3 -17.5 12/13/2004 00:20:00 18.1 2.2 23.3 13.3 17.5 2.3 22.9 13.3 0.4 0 0.4 0.4 31 6 37 305 70 0 71 0 -17.4 0 -16.9 -17.5 12/13/2004 00:30:00 19 1.6 23.3 14.5 18.6 1.7 22.9 14.5 0.4 0 0.4 0.4 31 5 35 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/13/2004 00:40:00 18.8 1.7 22.6 14.1 18.3 1.7 22.6 14.5 0.4 0 0.4 0.4 28 5 28 305 70 0 70 0 -17.5 0 -17.5 -17.5 12/13/2004 00:50:00 19.2 1.6 22.6 14.9 18.6 1.7 21.8 14.5 0.4 0 0.4 0.4 32 5 28 305 70 0 70 0 -17.5 0 -17.1 -17.7 12/13/2004 01:00:00 18.1 1.7 21.8 13.7 17.5 1.7 21 13 0.4 0 0.4 0.4 33 5 28 305 70 0 70 0 -17.5 0 -17.1 -17.7 12/13/2004 01:10:00 19.2 1.3 23.3 15.6 18.6 1.4 22.6 14.9 0.4 0 0.4 0.4 29 5 30 305 70 0 70 0 -17.6 0 -17.3 -17.9 12/13/2004 01:20:00 18.2 1.8 21.8 13.3 17.6 1.9 21.4 12.6 0.4 0 0.4 0.4 31 5 33 305 70 0 70 0 -17.6 0.1 -16.9 -17.9 12/13/2004 01:30:00 18.1 1.3 21.4 14.5 17.5 1.4 21 13.7 0.4 0 0.4 0.4 30 6 18 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/13/2004 01:40:00 17.8 1.3 20.2 13 17.2 1.3 19.9 12.6 0.4 0 0.4 0.4 37 6 28 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/13/2004 01:50:00 17.9 1.3 20.2 13.7 17.5 1.4 20.2 13.7 0.4 0 0.4 0.4 38 5 29 305 70 0 70 0 -17.6 0.1 -17.1 -17.9 12/13/2004 02:00:00 17.8 1.5 21 13.7 17.3 1.5 20.6 13 0.4 0 0.4 0.4 36 5 39 305 70 0 70 0 -17.6 0 -17.5 -17.7 12/13/2004 02:10:00 18.1 1.5 21.4 14.1 17.6 1.5 21 14.1 0.4 0 0.4 0.4 35 6 39 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/13/2004 02:20:00 18.1 1.5 21.4 14.1 17.5 1.5 21 13.7 0.4 0 0.4 0.4 34 6 27 305 70 0 70 0 -17.5 0 -16.9 -17.5 12/13/2004 02:30:00 19.3 1.5 22.6 15.6 18.7 1.7 22.1 14.5 0.4 0 0.4 0.4 32 5 30 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/13/2004 02:40:00 18.9 1.5 22.6 14.5 18.2 1.6 21.8 13.3 0.4 0 0.4 0.4 32 5 35 305 70 0 70 0 -17.5 0 -17.5 -17.7 12/13/2004 02:50:00 18.1 1.7 22.1 13.3 17.6 1.7 22.1 12.6 0.4 0 0.4 0.4 31 6 34 305 70 0 70 0 -17.5 0 -17.3 -17.7 12/13/2004 03:00:00 18.9 1.5 21.8 14.5 18.3 1.5 21.8 14.1 0.4 0 0.4 0.4 32 5 37 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/13/2004 03:10:00 18.5 1.5 21.8 14.5 18 1.5 21.4 13.7 0.4 0 0.4 0.4 32 5 33 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/13/2004 03:20:00 19.2 1.6 22.1 14.5 18.6 1.7 22.1 13.7 0.4 0 0.4 0.4 28 5 31 305 70 0 70 0 -17.6 0.1 -16.9 -17.7 12/13/2004 03:30:00 18.7 1.7 21.8 13.7 18.3 1.8 21.4 13.7 0.4 0 0.4 0.4 25 5 25 305 70 0 70 0 -17.6 0 -17.1 -17.9 12/13/2004 03:40:00 18.9 1.4 21.4 14.1 18.5 1.4 21.4 14.1 0.4 0 0.4 0.4 24 5 24 305 70 0 70 0 -17.6 0 -17.1 -17.7 12/13/2004 03:50:00 18.4 1.4 21 13.7 18 1.5 21 13.3 0.4 0 0.4 0.4 27 6 23 305 70 0 71 0 -17.5 0 -16.9 -17.7 12/13/2004 04:00:00 18.2 1.4 21.4 13.7 17.7 1.5 21.4 14.1 0.4 0 0.4 0.4 32 6 31 305 70 0 70 0 -17.5 0 -17.3 -17.7 12/13/2004 04:10:00 19.3 1.4 22.9 15.3 18.7 1.3 21.4 15.3 0.4 0 0.4 0.4 34 6 38 305 70 0 70 0 -17.6 0.1 -17.5 -17.9 12/13/2004 04:20:00 18.5 1.5 21.8 14.9 17.9 1.6 21 14.1 0.4 0 0.4 0.4 35 5 36 305 70 0 70 0 -17.7 0 -17.5 -17.9 12/13/2004 04:30:00 18.7 1.7 21.8 13.3 18.2 1.8 21.8 12.6 0.4 0 0.4 0.4 34 5 28 305 70 0 70 0 -17.6 0 -17.5 -17.7 12/13/2004 04:40:00 18.8 1.6 21.8 13.3 18.3 1.7 21.4 13 0.4 0 0.4 0.4 35 6 38 305 70 0 70 0 -17.7 0 -17.5 -17.9 12/13/2004 04:50:00 18.7 1.9 22.1 13.3 18.1 1.8 21.8 13 0.4 0 0.4 0.4 34 5 32 305 70 0 70 0 -17.6 0 -17.5 -17.7 12/13/2004 05:00:00 18.4 1.7 21.8 13.3 17.8 1.8 21.4 13 0.4 0 0.4 0.4 33 5 38 305 70 0 70 0 -17.7 0 -17.5 -17.9 12/13/2004 05:10:00 18.3 1.7 21.8 12.6 17.7 1.7 21 12.2 0.4 0 0.4 0.4 34 5 36 305 70 0 70 0 -17.7 0 -17.5 -17.9 12/13/2004 05:20:00 18.2 1.7 21.8 13.3 17.6 1.7 22.1 13 0.4 0 0.4 0.4 32 5 27 305 70 0 70 0 -17.5 0 -17.5 -17.9 12/13/2004 05:30:00 17.9 1.5 21.8 14.1 17.3 1.5 21.4 13.3 0.4 0 0.4 0.4 35 6 32 305 70 0 70 0 -17.5 0 -17.3 -17.7 12/13/2004 05:40:00 18.8 1.3 21.4 14.5 18.2 1.3 21 13 0.4 0 0.4 0.4 31 5 28 305 70 0 70 0 -17.5 0 -17.5 -17.7 12/13/2004 05:50:00 18.7 1.5 21.8 13.7 17.9 1.6 21.4 13 0.4 0 0.4 0.4 33 5 31 305 70 0 70 0 -17.5 0 -17.5 -17.7 12/13/2004 06:00:00 19.2 1.4 21.4 14.9 18.4 1.4 21 14.1 0.4 0 0.4 0.4 27 5 25 305 70 0 71 0 -17.5 0 -17.3 -17.5 12/13/2004 06:10:00 19.2 1.5 22.1 14.5 18.6 1.6 21.8 14.1 0.4 0 0.4 0.4 27 5 19 305 71 0 71 0 -17.4 0 -17.1 -17.5 12/13/2004 06:20:00 19.4 1.3 22.1 16.1 18.9 1.3 21.8 15.6 0.4 0 0.4 0.4 34 5 30 305 71 0 71 0 -17.3 0 -17.1 -17.5 12/13/2004 06:30:00 20.4 1.7 24 14.5 19.8 1.7 24 14.9 0.4 0 0.4 0.4 35 5 29 305 71 0 71 0 -17.3 0 -17.1 -17.5 12/13/2004 06:40:00 20.3 2 24.4 14.5 19.7 2 24 14.9 0.4 0 0.4 0.4 35 5 30 305 71 0 71 0 -17.2 0 -16.9 -17.3 12/13/2004 06:50:00 19.4 1.7 23.7 13.3 18.7 1.7 23.7 14.5 0.4 0 0.4 0.4 35 6 27 305 71 0 71 0 -17 0 -16.9 -17.3 12/13/2004 07:00:00 19.6 1.9 23.7 14.5 18.9 1.9 23.3 14.5 0.4 0 0.4 0.4 34 6 32 305 71 0 71 0 -17 0 -16.9 -17.1 12/13/2004 07:10:00 20.5 1.6 24 15.3 20.1 1.7 23.7 14.5 0.4 0 0.4 0.4 35 5 35 305 71 0 71 0 -17.1 0 -16.6 -17.3 12/13/2004 07:20:00 20 1.7 24.4 15.3 19.3 1.7 23.3 14.9 0.4 0 0.4 0.4 34 5 34 305 71 0 71 0 -17 0 -16.6 -17.1 12/13/2004 07:30:00 20.8 1.6 24 16.1 20.2 1.7 24.4 15.6 0.4 0 0.4 0.4 33 5 27 305 71 0 71 0 -17.1 0 -16.6 -17.3 12/13/2004 07:40:00 20.2 1.8 25.2 14.9 19.6 1.8 24 15.3 0.4 0 0.4 0.4 32 6 32 305 71 0 71 0 -17.1 0 -16.6 -17.3 12/13/2004 07:50:00 20.4 2 24 15.6 19.7 2 24 14.9 0.4 0 0.4 0.4 34 5 40 305 71 0 71 0 -17 0 -16.4 -17.1 12/13/2004 08:00:00 20.5 1.7 24 15.3 19.7 1.7 24 14.1 0.4 0 0.4 0.4 33 5 35 305 71 0 72 0 -16.9 0 -16.9 -16.9 12/13/2004 08:10:00 20.1 1.7 24 14.9 19.4 1.7 22.6 14.5 0.4 0 0.4 0.4 32 5 27 305 72 0 72 0 -16.8 0.1 -16.6 -16.9 12/13/2004 08:20:00 19.1 1.7 22.9 14.9 18.3 1.8 22.1 14.1 0.4 0 0.4 0.4 31 5 35 305 72 0 72 0 -16.6 0 -16.2 -16.7 12/13/2004 08:30:00 19.4 1.6 23.3 15.6 18.8 1.7 22.6 14.5 0.4 0 0.4 0.4 32 6 29 305 73 0 72 0 -16.4 0 -16.4 -16.6 12/13/2004 08:40:00 20.1 1.5 23.3 16.1 19.3 1.6 22.9 14.9 0.4 0 0.4 0.4 33 5 34 305 72 0 73 0 -16.5 0 -16.4 -16.6 12/13/2004 08:50:00 19.4 1.3 22.6 14.9 18.7 1.4 22.6 14.9 0.4 0 0.4 0.4 32 6 35 305 72 0 73 0 -16.5 0 -16.4 -16.7 12/13/2004 09:00:00 19.4 1.3 22.9 16.1 18.6 1.4 22.6 15.3 0.4 0 0.4 0.4 30 5 21 305 72 0 73 0 -16.6 0 -16 -16.9 12/13/2004 09:10:00 19.7 1.7 23.3 14.9 19 1.7 22.6 14.1 0.4 0 0.4 0.4 34 5 29 305 72 0 72 0 -16.7 0 -16 -16.9 12/13/2004 09:20:00 19.1 1.7 22.9 14.5 18.5 1.7 22.1 13.7 0.4 0 0.4 0.4 34 5 39 305 72 0 72 0 -16.7 0.1 -16.2 -16.9 12/13/2004 09:30:00 19.6 1.7 23.3 14.5 18.9 1.7 22.1 14.1 0.4 0 0.4 0.4 33 6 27 305 72 0 72 0 -16.8 0 -16.2 -16.9 12/13/2004 09:40:00 19 1.9 22.9 14.5 18.4 1.8 22.6 13.3 0.4 0 0.4 0.4 31 5 32 305 72 0 72 0 -16.9 0 -16.6 -16.9 12/13/2004 09:50:00 19 1.3 21.4 15.3 18.4 1.5 21 14.5 0.4 0 0.4 0.4 25 5 29 305 72 0 72 0 -16.9 0 -16.6 -16.9 12/13/2004 10:00:00 18.4 1.9 22.6 13.3 17.8 1.8 21.8 13.3 0.4 0 0.4 0.4 28 5 26 305 73 0 73 0 -16.8 0.1 -16.6 -16.9 12/13/2004 10:10:00 19.3 1.5 22.6 14.5 18.6 1.6 22.6 14.1 0.4 0 0.4 0.4 34 5 27 305 73 0 73 0 -16.7 0.1 -16.6 -16.9 12/13/2004 10:20:00 19.5 1.3 22.1 15.6 18.8 1.3 22.1 14.9 0.4 0 0.4 0.4 32 5 32 305 73 0 73 0 -16.7 0 -16.2 -16.9 12/13/2004 10:30:00 19.3 1.7 23.7 14.1 18.6 1.7 22.9 13.3 0.4 0 0.4 0.4 32 5 25 305 73 0 73 0 -16.6 0 -16.4 -16.9 12/13/2004 10:40:00 19.3 1.6 23.7 15.3 18.6 1.7 22.9 14.9 0.4 0 0.4 0.4 35 5 39 305 73 0 73 0 -16.5 0 -16.4 -16.6 12/13/2004 10:50:00 19.6 2.1 24 14.9 19 2.1 23.7 14.5 0.4 0 0.4 0.4 35 6 31 305 74 0 73 0 -16.4 0 -16.2 -16.6 12/13/2004 11:00:00 19.7 1.5 23.3 14.9 19.1 1.6 22.9 14.1 0.4 0 0.4 0.4 36 5 38 305 74 0 73 0 -16.2 0 -16 -16.4 12/13/2004 11:10:00 19.7 1.4 22.9 16.1 19 1.3 22.6 14.5 0.4 0 0.4 0.4 30 5 25 305 74 0 74 0 -16.1 0 -16 -16.4 12/13/2004 11:20:00 19.3 1.7 22.1 14.5 18.7 1.7 22.1 13 0.4 0 0.4 0.4 33 5 27 305 74 0 74 0 -16.1 0 -16 -16.4 12/13/2004 11:30:00 19.7 1.6 23.3 13.7 18.9 1.6 22.1 13.7 0.4 0 0.4 0.4 34 5 36 305 74 0 74 0 -16.2 0 -16 -16.4 12/13/2004 11:40:00 19.4 1.4 22.1 15.3 18.7 1.5 22.1 14.5 0.4 0 0.4 0.4 32 5 32 305 74 0 74 0 -16.1 0 -15.8 -16.4 12/13/2004 11:50:00 19.2 2 23.3 14.5 18.5 2 23.3 13.7 0.4 0 0.4 0.4 33 5 30 305 75 0 75 0 -16 0 -15.8 -16.2 12/13/2004 12:00:00 18.8 1.6 21.8 14.5 18.1 1.7 22.1 13.7 0.4 0 0.4 0.4 33 6 40 305 75 0 75 0 -15.9 0 -15.8 -16 12/13/2004 12:10:00 18.8 1.2 21.4 15.3 18.1 1.3 21 14.5 0.4 0 0.4 0.4 31 5 34 305 75 0 75 0 -15.8 0 -15.8 -16 12/13/2004 12:20:00 18.4 1.4 21.4 14.5 17.9 1.5 21.4 14.1 0.4 0 0.4 0.4 36 6 39 305 75 0 76 0 -15.8 0 -15.8 -16 12/13/2004 12:30:00 18.4 1.7 21.8 14.1 17.8 1.7 21.4 14.1 0.4 0 0.4 0.4 35 6 40 305 75 0 76 0 -15.8 0 -15.8 -16 12/13/2004 12:40:00 17.7 1.4 20.6 13.7 17.1 1.4 20.6 13.3 0.4 0 0.4 0.4 35 5 26 305 76 0 76 0 -15.8 0 -15.6 -15.8 12/13/2004 12:50:00 19.1 2.1 22.9 13 18.3 2.2 21.8 12.6 0.4 0 0.4 0.4 30 5 31 305 76 0 76 0 -15.8 0 -15.6 -16 12/13/2004 13:00:00 19.3 1.9 23.7 14.5 18.6 1.8 22.9 13.3 0.4 0 0.4 0.4 31 6 32 305 76 0 76 0 -15.8 0 -15.6 -16 12/13/2004 13:10:00 19.2 1.9 22.9 13.3 18.3 1.8 22.6 13.3 0.4 0 0.4 0.4 32 5 33 305 76 0 76 0 -15.8 0 -15.6 -16 12/13/2004 13:20:00 19.6 1.5 22.9 15.3 18.8 1.5 22.6 13.3 0.4 0 0.4 0.4 33 6 36 305 76 0 76 0 -15.8 0 -15.6 -16 12/13/2004 13:30:00 19 1.7 23.7 14.9 18.1 1.7 22.1 13.7 0.4 0 0.4 0.4 31 6 35 305 76 0 76 0 -15.8 0 -15.6 -15.8 12/13/2004 13:40:00 19.4 1.7 22.1 14.5 18.6 1.7 22.1 13.7 0.4 0 0.4 0.4 35 5 37 305 76 0 76 0 -15.8 0 -15.6 -16 12/13/2004 13:50:00 20 1.3 22.9 16.1 19.2 1.4 22.1 15.6 0.4 0 0.4 0.4 36 5 33 305 75 0 75 0 -15.9 0 -15.8 -16 12/13/2004 14:00:00 18.6 1.5 22.1 14.1 18 1.5 21 12.6 0.4 0 0.4 0.4 36 5 33 305 75 0 75 0 -15.8 0 -15.8 -16 12/13/2004 14:10:00 19.3 1.7 22.6 13.3 18.6 1.8 22.6 12.6 0.4 0 0.4 0.4 35 5 34 305 75 0 75 0 -15.8 0 -15.8 -16 12/13/2004 14:20:00 19.3 1.7 22.6 14.5 18.7 1.6 22.1 13.3 0.4 0 0.4 0.4 36 5 32 305 75 0 76 0 -15.9 0 -15.8 -16 12/13/2004 14:30:00 19.6 1.7 23.3 15.3 18.8 1.7 22.6 14.5 0.4 0 0.4 0.4 36 5 33 305 75 0 76 0 -15.9 0 -15.8 -16 12/13/2004 14:40:00 18.8 1.8 22.6 13 18 1.8 21.4 13 0.4 0 0.4 0.4 32 5 27 305 75 0 76 0 -15.8 0 -15.6 -16 12/13/2004 14:50:00 20 1.7 22.9 14.1 19.3 1.7 22.1 14.5 0.4 0 0.4 0.4 33 5 33 305 76 0 76 0 -15.8 0 -15.6 -16 12/13/2004 15:00:00 19.6 1.7 24 14.5 18.9 1.8 22.9 13.3 0.4 0 0.4 0.4 33 5 28 305 75 0 76 0 -15.8 0 -15.6 -15.8 12/13/2004 15:10:00 19.8 1.6 23.3 15.6 19.1 1.6 23.3 14.9 0.4 0 0.4 0.4 33 5 35 305 75 0 76 0 -15.7 0 -15.6 -15.8 12/13/2004 15:20:00 18.6 1.7 22.6 13.3 18 1.7 21.4 14.1 0.4 0 0.4 0.4 35 5 38 305 75 0 76 0 -15.6 0 -15.4 -15.8 12/13/2004 15:30:00 18.6 1.5 22.1 14.9 17.9 1.5 21.8 14.1 0.4 0 0.4 0.4 34 5 33 305 75 0 75 0 -15.7 0 -15.4 -15.8 12/13/2004 15:40:00 18.1 1.5 21 14.1 17.5 1.5 20.2 13.7 0.4 0 0.4 0.4 34 5 41 305 75 0 75 0 -15.6 0 -15.6 -15.8 12/13/2004 15:50:00 18.4 1.3 21.4 14.9 17.7 1.4 21 14.5 0.4 0 0.4 0.4 35 6 38 305 75 0 75 0 -15.6 0 -15.2 -15.6 12/13/2004 16:00:00 18.6 1.5 21.8 13 18 1.5 21.4 13 0.4 0 0.4 0.4 31 5 35 305 74 0 74 0 -15.5 0 -15.2 -15.6 12/13/2004 16:10:00 19.1 1.3 22.6 15.3 18.4 1.3 21.8 14.9 0.4 0 0.4 0.4 33 4 39 305 74 0 74 0 -15.5 0 -15.2 -15.6 12/13/2004 16:20:00 17.8 1.4 21 13.3 17.2 1.5 20.6 12.6 0.4 0 0.4 0.4 34 5 32 305 74 0 74 0 -15.5 0 -15.2 -15.6 12/13/2004 16:30:00 18.5 1.7 21.4 12.6 17.9 1.8 21 13 0.4 0 0.4 0.4 31 4 29 305 74 0 74 0 -15.4 0 -15.2 -15.6 12/13/2004 16:40:00 18.2 1.6 21 13 17.6 1.6 20.6 13.3 0.4 0 0.4 0.4 30 5 30 305 74 0 74 0 -15.5 0 -15.2 -15.6 12/13/2004 16:50:00 17.4 1.5 21 13.3 16.8 1.5 20.6 12.6 0.4 0 0.4 0.4 30 5 26 305 74 0 74 0 -15.4 0 -15.2 -15.6 12/13/2004 17:00:00 15.6 1.8 19.9 11.1 15.3 1.8 19.5 10.7 0.4 0 0.4 0.4 27 7 27 305 74 0 74 0 -15.3 0 -15 -15.6 12/13/2004 17:10:00 13.5 0.9 16.1 10.7 13.4 1 16.1 10.3 0.4 0 0.4 0.4 21 5 20 305 74 0 74 0 -15.6 0.1 -15.4 -15.8 12/13/2004 17:20:00 13.9 1.2 16.8 10.7 13.7 1.2 16.8 10.7 0.4 0 0.4 0.4 16 4 24 305 74 0 74 0 -15.7 0 -15.6 -15.8 12/13/2004 17:30:00 13.3 1.2 16.1 9.9 13.2 1.3 16.1 9.1 0.4 0 0.4 0.4 18 5 20 305 74 0 74 0 -15.8 0 -15.6 -15.8 12/13/2004 17:40:00 13.2 1 15.3 10.3 13 1.1 14.9 9.5 0.4 0 0.4 0.4 19 5 20 305 74 0 74 0 -15.8 0 -15.6 -16 12/13/2004 17:50:00 13.2 1.1 15.6 9.5 13 1.1 15.6 9.5 0.4 0 0.4 0.4 19 5 16 305 74 0 74 0 -15.8 0 -15.6 -15.8 12/13/2004 18:00:00 14.1 1.1 16.8 10.7 13.9 1.1 17.2 10.7 0.4 0 0.4 0.4 20 5 17 305 74 0 74 0 -15.7 0 -15.6 -15.8 12/13/2004 18:10:00 13.6 1.5 16.8 9.5 13.4 1.6 16.4 9.1 0.4 0 0.4 0.4 20 5 17 305 74 0 74 0 -15.5 0.1 -15.2 -15.6 12/13/2004 18:20:00 14.1 1.3 17.6 10.7 13.9 1.4 16.8 10.3 0.4 0 0.4 0.4 19 5 32 305 74 0 74 0 -15.6 0 -15.4 -15.6 12/13/2004 18:30:00 14 1.2 16.8 10.3 13.7 1.2 16.4 9.9 0.4 0 0.4 0.4 20 6 22 305 74 0 74 0 -15.6 0.1 -15.2 -15.8 12/13/2004 18:40:00 13.6 1 15.6 11.1 13.4 1 15.6 10.3 0.4 0 0.4 0.4 18 5 12 305 74 0 74 0 -15.8 0 -15.6 -16 12/13/2004 18:50:00 14 1 16.4 10.7 13.8 1.1 16.1 11.1 0.4 0 0.4 0.4 17 4 19 305 74 0 74 0 -15.8 0 -15.6 -16 12/13/2004 19:00:00 13.1 1.1 15.6 9.5 12.8 1.2 15.3 9.9 0.4 0 0.4 0.4 17 5 19 305 74 0 73 0 -15.8 0 -15.6 -16 12/13/2004 19:10:00 13.2 1 15.3 10.3 13.1 1 15.3 9.9 0.4 0 0.4 0.4 15 4 11 305 74 0 74 0 -15.8 0 -15.6 -16 12/13/2004 19:20:00 11.9 1 14.1 9.5 11.7 1 13.7 9.1 0.4 0 0.4 0.4 15 5 21 305 74 0 74 0 -15.8 0 -15.6 -15.8 12/13/2004 19:30:00 13 1.2 16.4 9.5 12.8 1.1 16.1 9.1 0.4 0 0.4 0.4 23 5 26 305 74 0 74 0 -15.6 0 -15.2 -15.8 12/13/2004 19:40:00 12.2 1.3 14.5 8.4 12 1.3 14.5 8.4 0.4 0 0.4 0.4 18 6 22 305 74 0 74 0 -15.6 0 -15.4 -15.8 12/13/2004 19:50:00 13 1 14.9 9.1 12.8 1.2 14.9 8.8 0.4 0 0.4 0.4 15 5 13 305 74 0 74 0 -15.8 0 -15.6 -16 12/13/2004 20:00:00 13.1 1.2 16.1 8.8 13 1.2 15.3 8.4 0.4 0 0.4 0.4 16 5 23 305 74 0 74 0 -15.8 0 -15.8 -16 12/13/2004 20:10:00 13.6 1 15.6 10.7 13.6 1 16.1 10.7 0.4 0 0.4 0.4 14 4 14 305 73 0 73 0 -15.9 0 -15.8 -16.2 12/13/2004 20:20:00 13.3 1.2 15.3 9.1 13.2 1.2 15.3 9.1 0.4 0 0.4 0.4 13 4 16 305 73 0 73 0 -16.1 0.1 -16 -16.4 12/13/2004 20:30:00 12.8 1.2 15.3 9.5 12.8 1.2 14.9 9.5 0.4 0 0.4 0.4 12 4 18 305 73 0 73 0 -16.2 0 -16 -16.4 12/13/2004 20:40:00 12.9 1.1 15.3 9.5 12.7 1.1 15.3 9.5 0.4 0 0.4 0.4 17 5 25 305 73 0 73 0 -16.1 0 -16 -16.2 12/13/2004 20:50:00 13.4 1.1 15.6 9.9 13.4 1.2 15.6 9.9 0.4 0 0.4 0.4 17 4 18 305 73 0 73 0 -16.1 0 -16 -16.2 12/13/2004 21:00:00 13.3 1 15.3 10.7 13 1 14.9 9.9 0.4 0 0.4 0.4 19 4 19 305 73 0 73 0 -16 0 -15.8 -16.2 12/13/2004 21:10:00 13 1 15.3 9.1 12.8 1.1 15.3 9.9 0.4 0 0.4 0.4 18 5 16 305 73 0 73 0 -16 0 -15.8 -16.2 12/13/2004 21:20:00 12.6 1.1 14.5 9.1 12.4 1.1 14.5 9.1 0.4 0 0.4 0.4 14 4 15 305 73 0 73 0 -16 0 -15.8 -16.2 12/13/2004 21:30:00 12.9 1.1 14.9 9.5 12.9 1.2 14.9 9.5 0.4 0 0.4 0.4 16 4 16 305 73 0 73 0 -16.1 0 -16 -16.2 12/13/2004 21:40:00 13.1 1.1 15.3 9.9 12.9 1.2 15.3 9.9 0.4 0 0.4 0.4 19 5 29 305 73 0 73 0 -16.1 0 -16 -16.4 12/13/2004 21:50:00 13.5 0.8 14.9 11.1 13.3 0.9 15.6 10.3 0.4 0 0.4 0.4 20 5 21 305 72 0 73 0 -16.3 0 -16 -16.4 12/13/2004 22:00:00 13.1 1.3 15.6 9.5 12.9 1.2 15.6 9.5 0.4 0 0.4 0.4 22 5 19 305 72 0 72 0 -16.3 0 -16 -16.4 12/13/2004 22:10:00 13.2 1.2 16.1 9.5 13.1 1.2 15.6 9.9 0.4 0 0.4 0.4 20 5 24 305 72 0 72 0 -16.3 0 -16 -16.4 12/13/2004 22:20:00 12.6 0.9 14.5 9.9 12.4 1 14.9 9.5 0.4 0 0.4 0.4 17 5 19 305 72 0 73 0 -16.3 0 -16.2 -16.4 12/13/2004 22:30:00 12.7 0.7 14.9 11.1 12.6 0.9 14.5 9.9 0.4 0 0.4 0.4 17 4 16 305 72 0 72 0 -16.4 0 -16.2 -16.6 12/13/2004 22:40:00 12 1 14.1 8.8 11.8 1.1 14.1 8.4 0.4 0 0.4 0.4 19 5 10 305 72 0 72 0 -16.3 0 -16.2 -16.4 12/13/2004 22:50:00 12.1 1 14.5 9.1 12 1 14.9 8.8 0.4 0 0.4 0.4 18 5 18 305 72 0 72 0 -16.2 0 -16 -16.4 12/13/2004 23:00:00 11.7 1.2 14.9 9.5 11.6 1.2 14.5 9.1 0.4 0 0.4 0.4 19 6 29 305 72 0 72 0 -16.3 0 -16 -16.4 12/13/2004 23:10:00 12 1 14.5 8.8 11.9 1.1 14.5 9.1 0.4 0 0.4 0.4 16 5 14 305 72 0 73 0 -16.3 0 -16 -16.6 12/13/2004 23:20:00 12.2 0.9 14.1 9.5 12 1.1 14.5 9.1 0.4 0 0.4 0.4 15 5 10 305 72 0 73 0 -16.4 0 -16.2 -16.6 12/13/2004 23:30:00 11.4 0.9 13.3 9.1 11.3 1 13.7 8.8 0.4 0 0.4 0.4 15 5 15 305 72 0 72 0 -16.4 0 -16.4 -16.6 12/13/2004 23:40:00 11.1 1.1 13 8.4 11 1.2 13.3 8 0.4 0 0.4 0.4 18 6 14 305 72 0 72 0 -16.5 0 -16.4 -16.6 12/13/2004 23:50:00 10.2 1 12.2 7.6 10.1 1 12.2 7.2 0.4 0 0.4 0.4 28 7 33 305 72 0 72 0 -16.4 0 -16.2 -16.6 12/14/2004 00:00:00 11.5 1 13.7 8.4 11.3 1 13.7 8.4 0.4 0 0.4 0.4 28 5 23 305 72 0 72 0 -16.4 0 -16 -16.6 12/14/2004 00:10:00 10.5 0.9 13 8 10.4 1 13 8 0.4 0 0.4 0.4 22 7 38 305 72 0 72 0 -16.4 0 -16.2 -16.6 12/14/2004 00:20:00 10.9 1.1 14.1 8 10.6 1.1 13.7 8 0.4 0 0.4 0.4 28 6 27 305 72 0 72 0 -16.3 0 -16 -16.4 12/14/2004 00:30:00 11.4 1 13.7 8.8 11.2 1.1 13.7 8.4 0.4 0 0.4 0.4 24 7 16 305 72 0 72 0 -16.3 0 -16 -16.6 12/14/2004 00:40:00 10.8 1.2 13.3 7.6 10.7 1.2 13.7 7.2 0.4 0 0.4 0.4 22 6 23 305 72 0 72 0 -16.2 0.1 -16 -16.4 12/14/2004 00:50:00 11.5 0.8 13.7 8.4 11.3 0.8 13.3 8.8 0.4 0 0.4 0.4 25 6 31 305 72 0 72 0 -16.2 0 -16 -16.4 12/14/2004 01:00:00 11.3 1 13 8.4 11.1 1 13 8.4 0.4 0 0.4 0.4 21 5 23 305 72 0 72 0 -16.2 0 -16 -16.4 12/14/2004 01:10:00 11 0.8 13 8.8 11 1 13 8.4 0.4 0 0.4 0.4 18 5 26 305 72 0 72 0 -16.4 0 -16.2 -16.6 12/14/2004 01:20:00 11.2 0.7 12.6 8.8 11.2 0.8 12.6 8.8 0.4 0 0.4 0.4 14 4 12 305 72 0 72 0 -16.4 0 -16.2 -16.6 12/14/2004 01:30:00 10.9 1 12.6 8.4 10.8 1.1 13 8.4 0.4 0 0.4 0.4 15 5 15 305 72 0 72 0 -16.4 0 -16.2 -16.6 12/14/2004 01:40:00 11.6 0.9 14.1 9.1 11.4 1 13.7 9.1 0.4 0 0.4 0.4 24 5 33 305 72 0 72 0 -16.4 0 -16.2 -16.6 12/14/2004 01:50:00 11.3 1 13.3 8.4 11.2 1 14.1 8.8 0.4 0 0.4 0.4 23 6 31 305 72 0 72 0 -16.4 0 -16.4 -16.6 12/14/2004 02:00:00 11.7 1 13.7 8.8 11.5 1 13.3 9.1 0.4 0 0.4 0.4 26 5 26 305 72 0 72 0 -16.4 0 -16.4 -16.6 12/14/2004 02:10:00 12 1 13.7 9.1 11.9 1 13.7 8.8 0.4 0 0.4 0.4 22 4 23 305 72 0 72 0 -16.5 0 -16.4 -16.6 12/14/2004 02:20:00 10.8 0.9 13 7.6 10.8 0.9 13 8 0.4 0 0.4 0.4 23 6 17 305 72 0 72 0 -16.4 0 -16.2 -16.6 12/14/2004 02:30:00 11 1 13 8.4 10.9 1 13 8 0.4 0 0.4 0.4 18 6 12 305 72 0 72 0 -16.4 0 -16.4 -16.6 12/14/2004 02:40:00 11 0.8 12.6 8.4 11 0.9 13 8 0.4 0 0.4 0.4 13 5 13 305 72 0 72 0 -16.7 0 -16.6 -16.9 12/14/2004 02:50:00 11.7 1.3 13.7 8 11.7 1.3 14.1 7.6 0.4 0 0.4 0.4 18 4 18 305 71 0 71 0 -16.8 0.1 -16.6 -16.9 12/14/2004 03:00:00 12.1 1 14.5 9.5 12.1 1 13.7 9.1 0.4 0 0.4 0.4 19 6 25 305 71 0 72 0 -16.8 0.1 -16.6 -16.9 12/14/2004 03:10:00 11.9 1 13.7 9.1 11.8 1.1 13.7 8.8 0.4 0 0.4 0.4 16 5 25 305 71 0 71 0 -16.7 0.1 -16.6 -16.9 12/14/2004 03:20:00 11.5 1 14.1 8.8 11.4 1 13.7 8.8 0.4 0 0.4 0.4 20 7 15 305 71 0 72 0 -16.7 0.1 -16.4 -16.9 12/14/2004 03:30:00 12.6 1.2 14.9 8.8 12.4 1.2 14.9 8.8 0.4 0 0.4 0.4 17 6 19 305 71 0 71 0 -16.7 0 -16.4 -16.9 12/14/2004 03:40:00 12.1 1 13.7 8.8 11.9 1.1 14.5 8.8 0.4 0 0.4 0.4 26 5 32 305 71 0 71 0 -16.7 0 -16.6 -16.9 12/14/2004 03:50:00 12.3 1 14.1 8.8 12.1 1 14.1 8.8 0.4 0 0.4 0.4 25 5 22 305 71 0 71 0 -16.7 0.1 -16.6 -16.9 12/14/2004 04:00:00 12 1 14.1 9.1 11.8 1 13.7 8.8 0.4 0 0.4 0.4 22 5 23 305 71 0 71 0 -16.7 0 -16.6 -16.9 12/14/2004 04:10:00 12.1 1 14.1 8.8 11.9 1 14.1 9.1 0.4 0 0.4 0.4 21 5 23 305 71 0 71 0 -16.7 0 -16.6 -16.9 12/14/2004 04:20:00 11.5 0.9 13.3 9.1 11.3 1 13.7 8.8 0.4 0 0.4 0.4 21 6 22 305 71 0 72 0 -16.7 0 -16.6 -16.9 12/14/2004 04:30:00 11.8 1 13.7 8.4 11.6 1.1 13.7 8 0.4 0 0.4 0.4 23 5 15 305 71 0 71 0 -16.8 0 -16.6 -16.9 12/14/2004 04:40:00 12.2 1 14.1 9.1 12 1 14.1 9.1 0.4 0 0.4 0.4 23 6 32 305 71 0 71 0 -16.9 0 -16.6 -16.9 12/14/2004 04:50:00 11 1.3 14.1 7.2 11 1.3 14.1 7.6 0.4 0 0.4 0.4 20 6 14 305 71 0 72 0 -16.9 0 -16.6 -16.9 12/14/2004 05:00:00 12 0.8 14.1 8.4 11.9 0.8 14.1 9.5 0.4 0 0.4 0.4 19 6 24 305 71 0 71 0 -16.9 0 -16.6 -16.9 12/14/2004 05:10:00 12.1 1 14.1 8.8 11.9 1.1 14.1 9.1 0.4 0 0.4 0.4 19 5 15 305 71 0 71 0 -16.9 0 -16.9 -17.1 12/14/2004 05:20:00 11.7 1.1 14.9 8.8 11.5 1.2 14.1 8.4 0.4 0 0.4 0.4 23 6 27 305 71 0 71 0 -16.9 0 -16.9 -16.9 12/14/2004 05:30:00 11.7 1 14.1 8.8 11.5 0.9 13.7 8.4 0.4 0 0.4 0.4 27 6 30 305 71 0 71 0 -16.9 0 -16.9 -16.9 12/14/2004 05:40:00 11 1.1 13.7 8.8 10.8 1.1 13.3 8.4 0.4 0 0.4 0.4 21 6 22 305 71 0 71 0 -16.9 0 -16.7 -16.9 12/14/2004 05:50:00 11.3 0.9 13 8 11.1 1 13.3 8.4 0.4 0 0.4 0.4 22 7 32 305 71 0 71 0 -17 0 -16.9 -17.1 12/14/2004 06:00:00 11.8 0.8 13.7 9.1 11.7 0.8 13.3 9.5 0.4 0 0.4 0.4 26 5 26 305 70 0 71 0 -17.1 0 -16.9 -17.3 12/14/2004 06:10:00 11.7 1 14.5 8.8 11.5 1 13.7 8.8 0.4 0 0.4 0.4 24 5 24 305 70 0 71 0 -17.2 0 -16.9 -17.3 12/14/2004 06:20:00 11.5 1.1 13.7 8.4 11.4 1.1 13.7 8.4 0.4 0 0.4 0.4 25 5 27 305 70 0 70 0 -17.2 0 -16.9 -17.3 12/14/2004 06:30:00 11.1 1 13.3 8.4 10.9 0.9 13.3 8 0.4 0 0.4 0.4 23 7 20 305 70 0 70 0 -17.2 0 -16.9 -17.3 12/14/2004 06:40:00 11.2 0.8 13 8.4 11 0.8 13 8.8 0.4 0 0.4 0.4 28 5 30 305 70 0 70 0 -17.3 0 -17.1 -17.5 12/14/2004 06:50:00 11.4 0.8 13.3 8.8 11.3 0.8 13.3 8.8 0.4 0 0.4 0.4 22 6 30 305 70 0 70 0 -17.4 0 -17.1 -17.5 12/14/2004 07:00:00 11 1 12.6 8.4 10.9 0.9 13 8.4 0.4 0 0.4 0.4 23 5 23 305 70 0 70 0 -17.4 0 -17.3 -17.5 12/14/2004 07:10:00 11.5 1 13.3 8.4 11.4 1 13.3 8.4 0.4 0 0.4 0.4 29 6 32 305 70 0 70 0 -17.4 0 -17.1 -17.5 12/14/2004 07:20:00 11.4 0.8 13.3 9.1 11.2 0.9 13 9.1 0.4 0 0.4 0.4 26 5 31 305 70 0 70 0 -17.4 0 -17.1 -17.5 12/14/2004 07:30:00 11.2 0.9 13.3 8.8 11.1 0.9 14.1 8.8 0.4 0 0.4 0.4 22 5 19 305 70 0 71 0 -17.3 0 -17.1 -17.5 12/14/2004 07:40:00 10.8 1.1 13 8.4 10.7 1 13 8.4 0.4 0 0.4 0.4 21 6 26 305 70 0 70 0 -17.2 0 -16.9 -17.5 12/14/2004 07:50:00 10.5 0.9 12.6 7.6 10.6 0.9 12.6 7.6 0.4 0 0.4 0.4 18 5 16 305 71 0 71 0 -17.1 0 -16.9 -17.3 12/14/2004 08:00:00 10.5 0.9 12.2 8.4 10.6 1 12.2 7.6 0.4 0 0.4 0.4 17 6 13 305 71 0 71 0 -17 0 -16.6 -17.1 12/14/2004 08:10:00 10.2 1.2 12.6 7.2 10.2 1.3 12.6 7.2 0.4 0 0.4 0.4 18 5 19 305 71 0 71 0 -16.9 0 -16.6 -16.9 12/14/2004 08:20:00 10.9 1 13 7.6 10.7 1 13 8 0.4 0 0.4 0.4 30 11 23 305 71 0 71 0 -16.7 0.1 -16.6 -16.9 12/14/2004 08:30:00 10.5 1 12.2 8 10.4 1 12.6 8 0.4 0 0.4 0.4 33 6 31 305 71 0 70 0 -16.9 0 -16.6 -16.9 12/14/2004 08:40:00 10.2 1 12.6 7.6 10 1 13 8 0.4 0 0.4 0.4 27 9 30 305 71 0 71 0 -16.9 0 -16.6 -16.9 12/14/2004 08:50:00 10.2 1.1 12.6 8 10.2 1.3 13 7.6 0.4 0 0.4 0.4 16 5 16 305 71 0 71 0 -17 0 -16.9 -17.3 12/14/2004 09:00:00 11.1 1 13.3 8.4 11 1 13 8.4 0.4 0 0.4 0.4 17 5 16 305 71 0 71 0 -17.3 0.1 -16.9 -17.5 12/14/2004 09:10:00 10.4 1.1 13 7.6 10.3 1 13 8 0.4 0 0.4 0.4 18 6 25 305 70 0 71 0 -17.4 0 -17.1 -17.5 12/14/2004 09:20:00 10.4 1.1 12.6 7.6 10.4 1 12.6 7.6 0.4 0 0.4 0.4 18 5 22 305 70 0 70 0 -17.5 0 -17.3 -17.5 12/14/2004 09:30:00 9.6 0.9 11.8 7.2 9.6 1 11.5 6.8 0.4 0 0.4 0.4 19 6 23 305 70 0 70 0 -17.5 0 -17.5 -17.7 12/14/2004 09:40:00 9.4 0.8 11.1 6.8 9.3 0.8 11.1 7.2 0.4 0 0.4 0.4 20 6 27 305 70 0 69 0 -17.5 0 -17.5 -17.7 12/14/2004 09:50:00 10 0.8 12.2 7.6 9.9 1 12.2 7.2 0.4 0 0.4 0.4 21 6 37 305 70 0 69 0 -17.5 0 -17.5 -17.7 12/14/2004 10:00:00 9.4 0.9 11.5 6.8 9.3 1 11.5 6.5 0.4 0 0.4 0.4 33 5 32 305 69 0 69 0 -17.5 0 -17.5 -17.9 12/14/2004 10:10:00 9.8 0.9 11.8 7.2 9.7 1 12.2 7.2 0.4 0 0.4 0.4 27 6 16 305 69 0 69 0 -17.7 0 -17.5 -17.9 12/14/2004 10:20:00 9.8 0.6 11.5 8 9.8 0.7 11.5 7.6 0.4 0 0.4 0.4 26 5 17 305 70 0 69 0 -17.6 0 -17.5 -17.9 12/14/2004 10:30:00 9.7 0.8 11.5 7.2 9.4 0.8 11.5 6.8 0.4 0 0.4 0.4 29 6 33 305 70 0 69 0 -17.5 0 -16.9 -17.7 12/14/2004 10:40:00 9.4 0.8 11.5 6.8 9.3 0.8 11.5 6.8 0.4 0 0.4 0.4 27 6 24 305 70 0 70 0 -17.3 0.1 -16.6 -17.5 12/14/2004 10:50:00 9 1 10.7 6.5 9 1 10.7 6.8 0.4 0 0.4 0.4 20 6 21 305 70 0 70 0 -17.1 0 -16.6 -17.3 12/14/2004 11:00:00 9.6 0.7 11.1 7.6 9.5 0.8 11.5 7.6 0.4 0 0.4 0.4 23 5 19 305 71 0 71 0 -16.9 0 -16.4 -16.9 12/14/2004 11:10:00 9.2 1 11.5 5.7 9.3 1 11.5 6.5 0.4 0 0.4 0.4 23 7 21 305 71 0 71 0 -16.9 0 -16.9 -16.9 12/14/2004 11:20:00 9.1 0.8 11.1 6.8 9 0.8 10.7 6.8 0.4 0 0.4 0.4 27 6 27 305 71 0 71 0 -16.9 0 -16.6 -16.9 12/14/2004 11:30:00 9.6 0.7 11.5 7.6 9.5 0.7 11.5 7.6 0.4 0 0.4 0.4 31 6 31 305 71 0 71 0 -16.9 0 -16.9 -16.9 12/14/2004 11:40:00 9.5 1 11.8 7.2 9.4 1 11.8 6.8 0.4 0 0.4 0.4 29 6 35 305 71 0 70 0 -17 0 -16.9 -17.1 12/14/2004 11:50:00 10.1 1 13 7.6 10.1 1 13 7.6 0.4 0 0.4 0.4 18 6 19 305 71 0 71 0 -17 0 -16.9 -17.1 12/14/2004 12:00:00 9.7 0.9 11.8 7.2 9.6 1 11.8 6.8 0.4 0 0.4 0.4 21 6 22 305 71 0 71 0 -17 0 -16.9 -17.1 12/14/2004 12:10:00 9.4 0.8 11.8 7.6 9.4 0.9 11.5 7.2 0.4 0 0.4 0.4 26 8 19 305 71 0 71 0 -16.9 0 -16.9 -17.1 12/14/2004 12:20:00 10.1 0.9 12.2 8 10 1 12.6 7.6 0.4 0 0.4 0.4 21 7 21 305 71 0 71 0 -17 0 -16.9 -17.3 12/14/2004 12:30:00 10.1 1 12.6 7.2 10 1 12.6 7.2 0.4 0 0.4 0.4 19 6 23 305 71 0 70 0 -17.2 0 -16.9 -17.3 12/14/2004 12:40:00 10.6 1.1 13 7.6 10.6 1.2 13.3 7.6 0.4 0 0.4 0.4 20 5 26 305 70 0 71 0 -17.3 0 -16.9 -17.5 12/14/2004 12:50:00 10 1 12.2 7.6 10 1 12.2 7.6 0.4 0 0.4 0.4 18 6 12 305 70 0 71 0 -17.4 0 -17.1 -17.5 12/14/2004 13:00:00 10.4 1.1 12.2 7.2 10.3 1.2 12.6 7.2 0.4 0 0.4 0.4 21 5 21 305 70 0 70 0 -17.4 0 -17.1 -17.5 12/14/2004 13:10:00 10 1 11.8 6.8 9.9 1 12.2 7.2 0.4 0 0.4 0.4 24 6 30 305 70 0 69 0 -17.4 0 -17.1 -17.5 12/14/2004 13:20:00 10.7 1 13 7.6 10.7 1.1 13 8 0.4 0 0.4 0.4 26 5 26 305 70 0 69 0 -17.5 0 -17.3 -17.7 12/14/2004 13:30:00 9.9 1 11.8 7.2 9.9 1 12.2 7.2 0.4 0 0.4 0.4 23 6 25 305 70 0 69 0 -17.4 0 -17.1 -17.5 12/14/2004 13:40:00 9.8 1 12.2 6.8 9.9 1 12.6 7.6 0.4 0 0.4 0.4 20 5 19 305 70 0 70 0 -17.4 0 -17.3 -17.5 12/14/2004 13:50:00 9.8 0.9 11.5 7.6 9.5 1 11.5 7.2 0.4 0 0.4 0.4 28 8 25 305 70 0 69 0 -17.4 0 -17.1 -17.5 12/14/2004 14:00:00 10.2 0.9 12.2 7.6 10.2 0.9 12.2 8 0.4 0 0.4 0.4 24 6 30 305 70 0 69 0 -17.4 0 -17.3 -17.5 12/14/2004 14:10:00 10.3 1 12.2 7.2 10 1 12.6 6.8 0.4 0 0.4 0.4 29 5 25 305 70 0 69 0 -17.5 0 -17.3 -17.7 12/14/2004 14:20:00 10.7 0.8 12.2 7.2 10.6 0.8 11.8 7.2 0.4 0 0.4 0.4 27 5 32 305 70 0 69 0 -17.5 0 -17.3 -17.5 12/14/2004 14:30:00 10.2 1 12.6 7.2 10 1 12.2 7.2 0.4 0 0.4 0.4 31 6 37 305 70 0 69 0 -17.4 0 -17.1 -17.5 12/14/2004 14:40:00 10.7 1.1 12.6 7.6 10.5 1 12.6 7.2 0.4 0 0.4 0.4 29 5 38 305 70 0 70 0 -17.4 0 -17.1 -17.5 12/14/2004 14:50:00 10.3 1 12.2 7.6 10.2 1 12.6 7.2 0.4 0 0.4 0.4 27 6 40 305 70 0 70 0 -17.4 0 -17.1 -17.5 12/14/2004 15:00:00 10.5 0.8 12.6 8.4 10.3 0.8 12.6 7.6 0.4 0 0.4 0.4 28 5 32 305 70 0 70 0 -17.4 0 -17.1 -17.5 12/14/2004 15:10:00 11 0.9 13 9.1 10.8 1 12.6 8 0.4 0 0.4 0.4 30 7 45 305 70 0 70 0 -17.4 0 -17.1 -17.5 12/14/2004 15:20:00 11.2 1.1 13.3 8.4 11 1.1 13.3 8 0.4 0 0.4 0.4 35 7 46 305 70 0 69 0 -17.4 0 -17.1 -17.5 12/14/2004 15:30:00 11.4 1 13.7 9.1 11.1 1 13 7.6 0.4 0 0.4 0.4 33 5 31 305 70 0 69 0 -17.4 0 -17.1 -17.5 12/14/2004 15:40:00 11.6 0.8 13.3 9.1 11.3 0.8 13.3 8.8 0.4 0 0.4 0.4 28 5 32 305 70 0 69 0 -17.4 0 -17.3 -17.5 12/14/2004 15:50:00 11.6 0.9 13.7 8.8 11.5 1 13.7 8.4 0.4 0 0.4 0.4 28 5 27 305 70 0 69 0 -17.4 0 -17.3 -17.5 12/14/2004 16:00:00 11.6 0.8 13.7 8.8 11.3 0.9 13.3 8.8 0.4 0 0.4 0.4 26 6 27 305 70 0 70 0 -17.5 0 -16.9 -17.7 12/14/2004 16:10:00 11.8 1 13.7 8.8 11.7 1 13.7 8.8 0.4 0 0.4 0.4 25 5 32 305 70 0 70 0 -17.5 0 -17.3 -17.7 12/14/2004 16:20:00 12.2 1 14.5 9.1 11.9 1.1 14.5 8.8 0.4 0 0.4 0.4 29 5 27 305 69 0 69 0 -17.5 0 -17.3 -17.7 12/14/2004 16:30:00 12.2 1 14.1 9.9 11.8 1 13.7 9.5 0.4 0 0.4 0.4 28 6 30 305 69 0 69 0 -17.5 0 -17.3 -17.7 12/14/2004 16:40:00 11.4 1 13.7 8 11.2 1 13.7 8 0.4 0 0.4 0.4 32 6 25 305 69 0 69 0 -17.5 0 -17.3 -17.5 12/14/2004 16:50:00 11.3 1.1 13.7 8.4 11.1 1.1 13.7 7.6 0.4 0 0.4 0.4 32 6 38 305 69 0 69 0 -17.5 0 -17.3 -17.7 12/14/2004 17:00:00 11.7 1 13.7 8.4 11.4 1 13.3 8.8 0.4 0 0.4 0.4 31 5 35 305 69 0 69 0 -17.6 0 -17.1 -17.9 12/14/2004 17:10:00 11.8 0.9 13.7 9.1 11.6 1 13.3 9.1 0.4 0 0.4 0.4 34 5 35 305 69 0 69 0 -17.7 0 -17.5 -17.9 12/14/2004 17:20:00 12.1 1 14.9 8.8 12 1 14.5 8.4 0.4 0 0.4 0.4 32 5 44 305 69 0 69 0 -17.8 0 -17.5 -17.9 12/14/2004 17:30:00 11.9 0.9 13.7 9.5 11.7 0.9 14.1 8.8 0.4 0 0.4 0.4 35 6 37 305 69 0 69 0 -17.7 0 -17.5 -17.9 12/14/2004 17:40:00 10.8 1.2 13.7 8 10.6 1.2 13.3 7.6 0.4 0 0.4 0.4 34 5 27 305 69 0 69 0 -17.6 0 -17.5 -17.9 12/14/2004 17:50:00 11 1 13.3 8.4 10.8 1.1 13 8 0.4 0 0.4 0.4 31 7 37 305 69 0 68 0 -17.5 0 -17.3 -17.7 12/14/2004 18:00:00 11.7 1 14.1 9.1 11.5 1 14.1 9.1 0.4 0 0.4 0.4 32 7 35 305 69 0 69 0 -17.5 0 -17.3 -17.7 12/14/2004 18:10:00 11 1.3 13.7 7.6 10.8 1.2 13.7 6.8 0.4 0 0.4 0.4 31 7 39 305 69 0 69 0 -17.5 0 -17.5 -17.7 12/14/2004 18:20:00 11.2 1.4 14.5 7.6 11 1.4 14.1 7.6 0.4 0 0.4 0.4 33 6 33 305 69 0 69 0 -17.5 0 -17.5 -17.9 12/14/2004 18:30:00 11.9 1.1 13.7 8.4 11.7 1.1 13.7 8.4 0.4 0 0.4 0.4 29 5 33 305 69 0 69 0 -17.7 0 -17.5 -17.9 12/14/2004 18:40:00 11.6 1 14.1 9.1 11.4 1 13.7 8.8 0.4 0 0.4 0.4 31 6 33 305 69 0 69 0 -17.7 0 -17.5 -17.9 12/14/2004 18:50:00 12.1 1 14.5 9.1 11.7 1 13.7 9.1 0.4 0 0.4 0.4 36 5 30 305 69 0 69 0 -17.7 0 -17.1 -17.9 12/14/2004 19:00:00 12.2 0.8 13.7 9.5 11.9 0.9 13.7 8.4 0.4 0 0.4 0.4 31 5 30 305 69 0 69 0 -17.7 0 -17.5 -17.9 12/14/2004 19:10:00 11.8 1 14.1 9.1 11.5 1.1 13.7 8.4 0.4 0 0.4 0.4 29 5 28 305 69 0 69 0 -17.7 0 -17.5 -17.9 12/14/2004 19:20:00 11.5 1 13.7 8.4 11.2 1.1 13.3 8.4 0.4 0 0.4 0.4 24 5 29 305 69 0 69 0 -17.6 0 -17.5 -17.9 12/14/2004 19:30:00 11.4 1 13.7 8.8 11.2 1.1 13.7 8.4 0.4 0 0.4 0.4 23 5 24 305 69 0 69 0 -17.5 0 -17.3 -17.7 12/14/2004 19:40:00 11.4 1 13.3 8.4 11.2 1.1 13.3 7.6 0.4 0 0.4 0.4 31 6 41 305 69 0 69 0 -17.3 0 -17.1 -17.5 12/14/2004 19:50:00 11.6 1.1 14.5 9.1 11.3 1.2 14.1 8.8 0.4 0 0.4 0.4 31 7 34 305 70 0 69 0 -17.4 0 -17.1 -17.5 12/14/2004 20:00:00 12.3 0.8 13.7 9.9 11.9 1 14.1 8 0.4 0 0.4 0.4 30 5 22 305 70 0 70 0 -17.3 0 -16.9 -17.5 12/14/2004 20:10:00 11.3 1 13.3 8.4 11.1 1.1 13.3 8.4 0.4 0 0.4 0.4 30 7 20 305 70 0 69 0 -17.3 0 -16.9 -17.5 12/14/2004 20:20:00 11.4 1.2 13.7 8.4 11.2 1.3 13.7 7.6 0.4 0 0.4 0.4 25 6 17 305 70 0 70 0 -17.3 0 -16.9 -17.5 12/14/2004 20:30:00 12.4 1.2 14.9 9.1 12.1 1.2 14.5 8.8 0.4 0 0.4 0.4 29 9 25 305 70 0 70 0 -17.3 0.1 -16.9 -17.5 12/14/2004 20:40:00 12.9 0.8 14.5 10.7 12.7 0.8 14.9 10.7 0.4 0 0.4 0.4 27 6 30 305 70 0 69 0 -17.4 0 -16.9 -17.5 12/14/2004 20:50:00 13.5 0.9 15.6 9.9 13.1 1 15.3 9.9 0.4 0 0.4 0.4 27 5 27 305 69 0 70 0 -17.5 0 -16.9 -17.7 12/14/2004 21:00:00 13.3 0.9 14.9 10.3 12.9 1 15.3 9.9 0.4 0 0.4 0.4 27 5 24 305 69 0 69 0 -17.6 0 -17.5 -17.9 12/14/2004 21:10:00 13.5 0.9 15.3 9.9 13.1 1 15.3 9.9 0.4 0 0.4 0.4 31 5 33 305 69 0 69 0 -17.6 0 -17.5 -17.7 12/14/2004 21:20:00 12.9 1.1 15.3 9.9 12.7 1.1 14.9 9.5 0.4 0 0.4 0.4 34 5 33 305 69 0 69 0 -17.6 0 -17.5 -17.9 12/14/2004 21:30:00 13.3 1 15.6 9.9 12.8 1.1 15.6 10.3 0.4 0 0.4 0.4 33 5 31 305 69 0 69 0 -17.6 0 -17.5 -17.9 12/14/2004 21:40:00 13.6 1 15.6 10.7 13.2 1 15.3 10.3 0.4 0 0.4 0.4 33 4 36 305 69 0 69 0 -17.6 0 -17.5 -17.9 12/14/2004 21:50:00 14.1 1 16.1 10.3 13.7 1 16.1 9.9 0.4 0 0.4 0.4 29 5 31 305 69 0 69 0 -17.5 0 -17.5 -17.7 12/14/2004 22:00:00 13.9 1 15.6 9.9 13.5 1 15.3 10.3 0.4 0 0.4 0.4 28 5 25 305 69 0 69 0 -17.5 0 -17.5 -17.7 12/14/2004 22:10:00 13.7 0.8 15.6 11.1 13.5 0.9 15.6 10.3 0.4 0 0.4 0.4 25 4 21 305 69 0 69 0 -17.5 0 -17.5 -17.7 12/14/2004 22:20:00 13.2 1.1 15.6 9.9 12.8 1.2 15.3 9.1 0.4 0 0.4 0.4 26 5 29 305 69 0 69 0 -17.5 0 -17.5 -17.7 12/14/2004 22:30:00 12.9 1 14.9 9.9 12.5 1 14.9 9.5 0.4 0 0.4 0.4 27 6 31 305 69 0 69 0 -17.5 0 -17.5 -17.7 12/14/2004 22:40:00 13.4 1.1 15.3 10.3 13.2 1.2 15.6 9.5 0.4 0 0.4 0.4 26 5 26 305 69 0 69 0 -17.5 0 -17.5 -17.5 12/14/2004 22:50:00 13.1 0.8 14.9 10.7 12.9 0.8 14.5 10.3 0.4 0 0.4 0.4 27 4 31 305 69 0 69 0 -17.5 0 -17.3 -17.7 12/14/2004 23:00:00 12.9 1.1 15.3 9.9 12.6 1.1 14.9 9.1 0.4 0 0.4 0.4 28 4 37 305 69 0 69 0 -17.4 0 -17.3 -17.5 12/14/2004 23:10:00 13.3 0.8 14.9 11.1 12.9 0.8 15.3 11.1 0.4 0 0.4 0.4 28 5 21 305 69 0 69 0 -17.4 0 -17.3 -17.5 12/14/2004 23:20:00 12.4 1.1 14.5 8.8 12.2 1.1 14.5 8.8 0.4 0 0.4 0.4 27 5 28 305 69 0 69 0 -17.4 0 -17.1 -17.5 12/14/2004 23:30:00 12.1 1.2 14.5 8.4 12 1.1 14.1 8.8 0.4 0 0.4 0.4 24 5 28 305 69 0 69 0 -17.4 0 -16.9 -17.5 12/14/2004 23:40:00 11.6 1.1 13.7 8.4 11.4 1.1 13.7 8.4 0.4 0 0.4 0.4 23 5 24 305 70 0 69 0 -17.3 0 -17.1 -17.5 12/14/2004 23:50:00 10.9 1 13.3 8 10.8 1 13 8 0.4 0 0.4 0.4 25 5 26 305 70 0 70 0 -17.3 0 -17.1 -17.5 12/15/2004 00:00:00 10.7 1.1 13 7.6 10.5 1.2 13 7.6 0.4 0 0.4 0.4 25 6 27 305 70 0 69 0 -17.2 0 -16.9 -17.3 12/15/2004 00:10:00 11.7 1 13.7 8.8 11.4 1 13.7 8.8 0.4 0 0.4 0.4 26 5 21 305 70 0 70 0 -17.3 0 -17.1 -17.5 12/15/2004 00:20:00 11.1 1.1 13.3 8.4 10.9 1.1 13.3 8.4 0.4 0 0.4 0.4 27 5 27 305 70 0 69 0 -17.3 0 -17.1 -17.3 12/15/2004 00:30:00 11.6 1 13.3 8.4 11.3 1.1 13.3 8 0.4 0 0.4 0.4 25 6 23 305 70 0 70 0 -17.3 0 -17.1 -17.5 12/15/2004 00:40:00 12 1 14.1 9.5 11.7 1 14.1 9.1 0.4 0 0.4 0.4 27 5 29 305 69 0 69 0 -17.3 0 -17.1 -17.5 12/15/2004 00:50:00 11.7 1 13.7 8.8 11.5 1 13.7 8.8 0.4 0 0.4 0.4 27 5 27 305 70 0 69 0 -17.3 0 -16.9 -17.5 12/15/2004 01:00:00 12.2 0.8 14.1 9.9 12.1 0.9 14.1 9.5 0.4 0 0.4 0.4 24 4 23 305 69 0 69 0 -17.3 0 -17.1 -17.5 12/15/2004 01:10:00 12.5 1 14.5 9.5 12.4 1.1 14.5 9.5 0.4 0 0.4 0.4 25 5 24 305 69 0 69 0 -17.3 0 -17.1 -17.5 12/15/2004 01:20:00 13.6 0.7 15.3 11.5 13.4 0.9 14.9 10.7 0.4 0 0.4 0.4 24 4 18 305 69 0 69 0 -17.3 0 -17.1 -17.5 12/15/2004 01:30:00 13.7 0.8 15.6 11.1 13.4 0.9 15.3 10.7 0.4 0 0.4 0.4 28 5 24 305 69 0 69 0 -17.3 0 -17.1 -17.5 12/15/2004 01:40:00 13.1 1.2 16.1 10.3 12.8 1.2 15.6 10.3 0.4 0 0.4 0.4 27 5 27 305 69 0 69 0 -17.2 0 -17.1 -17.3 12/15/2004 01:50:00 13.2 1 15.3 10.3 12.8 1 14.9 9.9 0.4 0 0.4 0.4 27 5 28 305 69 0 69 0 -17.3 0 -16.9 -17.5 12/15/2004 02:00:00 12.9 1.2 15.3 9.5 12.6 1.3 15.3 8.8 0.4 0 0.4 0.4 25 5 25 305 70 0 69 0 -17.2 0 -17.1 -17.5 12/15/2004 02:10:00 13.1 1.3 16.1 10.3 12.9 1.3 16.1 9.1 0.4 0 0.4 0.4 23 5 23 305 70 0 69 0 -17.3 0 -17.1 -17.5 12/15/2004 02:20:00 12.6 1.2 14.9 9.5 12.4 1.3 14.9 8.8 0.4 0 0.4 0.4 26 6 19 305 70 0 69 0 -17.3 0 -16.9 -17.5 12/15/2004 02:30:00 13.1 1.5 15.6 8.8 12.8 1.6 16.1 9.1 0.4 0 0.4 0.4 28 5 28 305 70 0 70 0 -17.1 0 -16.9 -17.3 12/15/2004 02:40:00 13.5 1 15.6 10.7 13.2 1 15.3 9.9 0.4 0 0.4 0.4 29 4 29 305 70 0 70 0 -17.1 0 -16.9 -17.3 12/15/2004 02:50:00 13.3 1.1 15.6 9.5 13 1.1 15.3 9.9 0.4 0 0.4 0.4 28 5 28 305 70 0 70 0 -17 0 -16.9 -17.1 12/15/2004 03:00:00 14 1 16.1 10.7 13.7 1.1 16.1 11.1 0.4 0 0.4 0.4 28 5 28 305 70 0 70 0 -17 0 -16.9 -17.3 12/15/2004 03:10:00 14.1 1.2 16.4 10.7 13.7 1.1 16.1 10.3 0.4 0 0.4 0.4 29 5 31 305 70 0 70 0 -17 0 -16.9 -17.1 12/15/2004 03:20:00 14.2 1 16.4 11.1 13.8 1 16.1 10.7 0.4 0 0.4 0.4 30 4 32 305 70 0 70 0 -17 0 -16.9 -17.1 12/15/2004 03:30:00 13.5 1.2 16.1 10.7 13.3 1.2 15.6 10.7 0.4 0 0.4 0.4 27 5 28 305 70 0 70 0 -17 0 -16.9 -17.1 12/15/2004 03:40:00 13.4 1 15.6 10.3 13.1 1 15.3 10.3 0.4 0 0.4 0.4 29 5 27 305 70 0 70 0 -16.9 0 -16.6 -17.1 12/15/2004 03:50:00 13.1 1.1 16.1 10.3 13 1.2 16.1 10.3 0.4 0 0.4 0.4 27 5 23 305 70 0 71 0 -16.8 0 -16.6 -16.9 12/15/2004 04:00:00 13.6 1 15.3 10.7 13.3 1 15.3 9.9 0.4 0 0.4 0.4 27 4 27 305 70 0 71 0 -16.8 0.1 -16.6 -16.9 12/15/2004 04:10:00 13.2 1.1 15.6 10.7 13 1.1 15.3 10.3 0.4 0 0.4 0.4 25 4 23 305 71 0 71 0 -16.5 0 -16.4 -16.7 12/15/2004 04:20:00 13 1.3 15.6 10.3 12.6 1.3 15.6 9.9 0.4 0 0.4 0.4 31 5 27 305 71 0 71 0 -16.2 0.1 -16 -16.6 12/15/2004 04:30:00 13.1 1.1 16.1 9.9 12.8 1.1 15.3 9.5 0.4 0 0.4 0.4 33 5 31 305 71 0 71 0 -16.2 0 -16 -16.4 12/15/2004 04:40:00 13.2 1.1 16.1 9.9 12.9 1.2 15.6 9.9 0.4 0 0.4 0.4 32 5 31 305 72 0 72 0 -16.1 0 -16 -16.2 12/15/2004 04:50:00 12.3 1 15.3 9.9 11.9 1.1 15.3 9.5 0.4 0 0.4 0.4 29 5 33 305 72 0 72 0 -16.1 0 -16 -16.2 12/15/2004 05:00:00 13 1.1 16.1 10.3 12.7 1.1 14.9 9.9 0.4 0 0.4 0.4 29 5 31 305 72 0 72 0 -16.1 0 -16 -16.4 12/15/2004 05:10:00 13 1 14.9 10.3 12.8 1.1 15.3 9.9 0.4 0 0.4 0.4 27 5 27 305 72 0 72 0 -16 0 -15.8 -16.2 12/15/2004 05:20:00 12.7 1.2 15.6 9.5 12.6 1.2 15.3 9.5 0.4 0 0.4 0.4 26 5 30 305 72 0 72 0 -15.8 0 -15.6 -16 12/15/2004 05:30:00 13 1.2 16.4 10.3 13 1.1 15.3 9.9 0.4 0 0.4 0.4 28 6 30 305 72 0 72 0 -15.8 0 -15.6 -16 12/15/2004 05:40:00 12.6 1 14.5 10.3 12.3 1.1 14.9 9.5 0.4 0 0.4 0.4 32 5 34 305 72 0 72 0 -15.8 0 -15.6 -15.8 12/15/2004 05:50:00 12.8 1.3 15.6 9.1 12.5 1.3 16.1 9.1 0.4 0 0.4 0.4 29 6 30 305 72 0 72 0 -15.8 0 -15.6 -15.8 12/15/2004 06:00:00 12.9 1.2 15.6 9.5 12.5 1.2 15.6 9.1 0.4 0 0.4 0.4 28 5 22 305 72 0 72 0 -15.9 0 -15.6 -16 12/15/2004 06:10:00 12.8 1.3 15.6 9.9 12.4 1.2 15.6 9.1 0.4 0 0.4 0.4 32 6 31 305 72 0 72 0 -15.9 0 -15.8 -16 12/15/2004 06:20:00 13.7 1.3 16.4 10.3 13.4 1.3 16.1 9.9 0.4 0 0.4 0.4 32 5 29 305 72 0 72 0 -16 0 -15.8 -16.2 12/15/2004 06:30:00 13 1.2 15.6 9.9 12.7 1.2 15.6 9.5 0.4 0 0.4 0.4 33 5 24 305 72 0 72 0 -16 0 -15.8 -16.2 12/15/2004 06:40:00 12.8 1.1 15.6 9.9 12.4 1.1 14.9 9.9 0.4 0 0.4 0.4 29 6 29 305 72 0 72 0 -15.9 0 -15.8 -16 12/15/2004 06:50:00 11.9 1.2 15.6 9.1 11.6 1.2 14.5 8.4 0.4 0 0.4 0.4 30 6 36 305 72 0 72 0 -15.8 0 -15.8 -16 12/15/2004 07:00:00 12.2 1.3 15.6 8.4 12 1.3 14.9 8.4 0.4 0 0.4 0.4 31 6 22 305 72 0 72 0 -15.8 0 -15.6 -16 12/15/2004 07:10:00 12.1 1.7 14.9 7.6 11.8 1.5 14.9 8.4 0.4 0 0.4 0.4 30 6 27 305 72 0 72 0 -15.8 0 -15.6 -16 12/15/2004 07:20:00 12.7 1.6 16.8 9.1 12.4 1.5 16.1 8.8 0.4 0 0.4 0.4 29 6 27 305 72 0 72 0 -15.8 0 -15.6 -16 12/15/2004 07:30:00 12 1.5 15.3 8.4 11.6 1.4 14.9 8.4 0.4 0 0.4 0.4 32 6 40 305 72 0 72 0 -15.8 0 -15.6 -15.8 12/15/2004 07:40:00 11.8 1.2 14.9 8.8 11.5 1.2 14.1 8.8 0.4 0 0.4 0.4 32 5 29 305 72 0 72 0 -15.8 0 -15.6 -15.8 12/15/2004 07:50:00 13 1.3 16.1 9.5 12.5 1.3 15.3 9.1 0.4 0 0.4 0.4 31 6 33 305 72 0 72 0 -15.7 0 -15.4 -15.8 12/15/2004 08:00:00 13.1 1 15.6 10.3 12.7 1.1 15.6 9.9 0.4 0 0.4 0.4 30 5 28 305 72 0 72 0 -15.7 0 -15.6 -15.8 12/15/2004 08:10:00 13 1.2 16.4 9.5 12.7 1.2 15.6 9.1 0.4 0 0.4 0.4 26 5 24 305 73 0 72 0 -15.5 0 -15.4 -15.6 12/15/2004 08:20:00 12.2 1.3 16.1 8.4 12 1.3 15.6 8.8 0.4 0 0.4 0.4 25 6 31 305 73 0 73 0 -15.5 0 -15.2 -15.6 12/15/2004 08:30:00 12.7 1.5 16.4 9.1 12.5 1.4 16.4 8.8 0.4 0 0.4 0.4 25 6 27 305 73 0 73 0 -15.4 0 -15 -15.6 12/15/2004 08:40:00 13.2 1.4 16.8 8.8 12.8 1.3 16.4 9.5 0.4 0 0.4 0.4 24 6 23 305 73 0 73 0 -15.3 0 -15 -15.4 12/15/2004 08:50:00 12.5 1.3 16.1 9.1 12.1 1.2 15.3 9.1 0.4 0 0.4 0.4 22 6 17 305 73 0 73 0 -15.3 0 -15 -15.6 12/15/2004 09:00:00 12.3 1.5 15.6 8 12 1.5 14.9 7.2 0.4 0 0.4 0.4 23 5 18 305 73 0 72 0 -15.4 0 -15 -15.6 12/15/2004 09:10:00 11.6 1.3 15.6 8 11.3 1.3 15.6 8.4 0.4 0 0.4 0.4 23 6 26 305 73 0 72 0 -15.5 0 -15.2 -15.6 12/15/2004 09:20:00 11.6 1.5 15.6 8.8 11.4 1.5 15.6 8 0.4 0 0.4 0.4 25 7 31 305 72 0 72 0 -15.5 0 -15.2 -15.6 12/15/2004 09:30:00 11.9 1.6 15.6 7.2 11.7 1.5 15.6 8 0.4 0 0.4 0.4 24 6 27 305 72 0 72 0 -15.4 0 -15.2 -15.6 12/15/2004 09:40:00 12.1 1.1 15.3 9.5 11.9 1.1 14.5 8.8 0.4 0 0.4 0.4 24 6 22 305 73 0 72 0 -15.3 0 -15.2 -15.6 12/15/2004 09:50:00 12.8 1.4 16.8 9.5 12.3 1.3 16.1 9.1 0.4 0 0.4 0.4 23 6 31 305 73 0 73 0 -15.3 0 -15 -15.4 12/15/2004 10:00:00 11.9 1.5 16.1 8.8 11.7 1.5 16.1 8.4 0.4 0 0.4 0.4 23 6 28 305 73 0 73 0 -15.3 0 -15 -15.2 12/15/2004 10:10:00 12.5 1.4 16.4 9.1 12.3 1.4 16.1 9.1 0.4 0 0.4 0.4 23 5 21 305 73 0 73 0 -15.1 0 -15 -15.2 12/15/2004 10:20:00 12.4 1.4 15.6 8.8 12 1.4 15.3 8.4 0.4 0 0.4 0.4 22 6 25 305 73 0 73 0 -14.9 0 -14.6 -15 12/15/2004 10:30:00 12.1 1.2 15.3 9.5 11.8 1.3 15.6 8.8 0.4 0 0.4 0.4 22 6 28 305 74 0 74 0 -14.7 0 -14.6 -14.8 12/15/2004 10:40:00 12.6 1.3 16.1 9.5 12.3 1.2 14.9 9.1 0.4 0 0.4 0.4 22 6 11 305 74 0 74 0 -14.6 0 -14.4 -14.6 12/15/2004 10:50:00 13.2 1.6 16.8 9.9 12.9 1.7 16.8 8.8 0.4 0 0.4 0.4 25 5 35 305 74 0 74 0 -14.5 0 -14.4 -14.6 12/15/2004 11:00:00 14.1 1.5 17.6 9.9 13.7 1.5 17.2 9.9 0.4 0 0.4 0.4 25 6 18 305 74 0 74 0 -14.4 0 -14.3 -14.6 12/15/2004 11:10:00 15.1 1.5 18.7 11.1 14.7 1.5 19.1 10.7 0.4 0 0.4 0.4 25 5 22 305 74 0 74 0 -14.3 0 -14.3 -14.6 12/15/2004 11:20:00 14.8 1.3 18.3 9.9 14.6 1.4 17.6 9.9 0.4 0 0.4 0.4 24 5 26 305 74 0 74 0 -14.2 0 -14.1 -14.4 12/15/2004 11:30:00 13.7 1.3 16.4 10.3 13.5 1.3 16.8 9.9 0.4 0 0.4 0.4 25 5 29 305 75 0 75 0 -14.1 0 -13.9 -14.3 12/15/2004 11:40:00 13.4 1.3 17.2 9.5 13 1.3 16.8 8.8 0.4 0 0.4 0.4 26 5 30 305 75 0 75 0 -13.8 0 -13.5 -14.1 12/15/2004 11:50:00 15.1 2 19.9 10.7 14.6 2 19.1 9.9 0.4 0 0.4 0.4 29 6 27 305 76 0 76 0 -13.6 0 -13.3 -13.7 12/15/2004 12:00:00 16.1 2.2 21 11.5 15.6 2.1 20.6 11.1 0.4 0 0.4 0.4 31 6 28 305 76 0 76 0 -13.5 0 -13.3 -13.7 12/15/2004 12:10:00 16.8 1.4 19.9 12.2 16.3 1.3 19.1 11.8 0.4 0 0.4 0.4 31 5 36 305 76 0 76 0 -13.5 0.1 -13.1 -13.7 12/15/2004 12:20:00 16 2 20.2 11.5 15.4 2 20.2 10.7 0.4 0 0.4 0.4 30 5 26 305 76 0 76 0 -13.4 0 -13.1 -13.7 12/15/2004 12:30:00 16 2.1 20.2 10.7 15.5 2.1 20.6 10.3 0.4 0 0.4 0.4 30 6 31 305 76 0 76 0 -13.4 0 -13.1 -13.5 12/15/2004 12:40:00 16 1.9 20.2 12.2 15.4 1.9 19.9 11.1 0.4 0 0.4 0.4 29 5 30 305 76 0 76 0 -13.4 0 -13.1 -13.5 12/15/2004 12:50:00 16.2 1.7 21 11.8 15.7 1.7 20.2 11.5 0.4 0 0.4 0.4 30 6 43 305 76 0 76 0 -13.3 0 -12.9 -13.5 12/15/2004 13:00:00 16.1 1.5 19.1 12.2 15.5 1.4 19.1 11.1 0.4 0 0.4 0.4 29 5 31 305 76 0 76 0 -13.2 0 -12.9 -13.3 12/15/2004 13:10:00 16.3 1.7 21.4 12.2 15.8 1.8 20.6 11.8 0.4 0 0.4 0.4 27 5 26 305 76 0 76 0 -13.1 0 -12.9 -13.3 12/15/2004 13:20:00 15.3 1.7 20.2 11.1 14.9 1.7 19.5 10.3 0.4 0 0.4 0.4 26 6 19 305 76 0 77 0 -13.1 0 -12.9 -13.3 12/15/2004 13:30:00 16 1.6 20.6 11.8 15.6 1.7 20.2 11.1 0.4 0 0.4 0.4 26 6 29 305 77 0 77 0 -13.1 0 -12.9 -13.3 12/15/2004 13:40:00 16.5 1.7 21 12.2 16 1.7 20.2 12.2 0.4 0 0.4 0.4 28 6 32 305 77 0 77 0 -13.1 0 -12.9 -13.3 12/15/2004 13:50:00 17.3 1.6 20.6 12.6 16.7 1.7 20.2 11.5 0.4 0 0.4 0.4 27 5 27 305 77 0 77 0 -13.1 0 -12.9 -13.3 12/15/2004 14:00:00 17 1.7 21.4 12.2 16.5 1.7 21 13 0.4 0 0.4 0.4 27 5 35 305 76 0 77 0 -13.1 0 -12.9 -13.3 12/15/2004 14:10:00 16.8 1.7 22.6 13 16.3 1.7 22.1 12.6 0.4 0 0.4 0.4 29 5 27 305 76 0 76 0 -13 0 -12.9 -13.1 12/15/2004 14:20:00 16.4 1.7 19.9 11.8 16 1.6 19.5 11.5 0.4 0 0.4 0.4 28 6 35 305 76 0 77 0 -13 0 -12.9 -13.1 12/15/2004 14:30:00 16.9 1.7 21 13 16.5 1.7 21 12.2 0.4 0 0.4 0.4 26 5 21 305 77 0 77 0 -12.9 0 -12.9 -13.1 12/15/2004 14:40:00 16.1 1.7 20.2 12.6 15.8 1.7 19.9 11.8 0.4 0 0.4 0.4 27 5 24 305 77 0 77 0 -12.9 0 -12.7 -12.9 12/15/2004 14:50:00 16.1 1.6 20.2 11.8 15.7 1.5 20.2 11.8 0.4 0 0.4 0.4 28 5 28 305 77 0 77 0 -12.8 0 -12.7 -12.9 12/15/2004 15:00:00 15 1.5 18.7 11.1 14.6 1.5 18.3 10.7 0.4 0 0.4 0.4 26 5 29 305 77 0 77 0 -12.7 0 -12.5 -12.9 12/15/2004 15:10:00 17 1.7 21.8 11.8 16.5 1.7 21.4 12.2 0.4 0 0.4 0.4 24 5 22 305 77 0 77 0 -12.9 0 -12.7 -12.9 12/15/2004 15:20:00 15.8 2 19.9 11.1 15.5 1.9 19.5 10.7 0.4 0 0.4 0.4 24 5 18 305 77 0 77 0 -12.8 0 -12.7 -12.9 12/15/2004 15:30:00 16.6 1.7 20.6 12.2 16.2 1.7 20.2 12.2 0.4 0 0.4 0.4 24 6 17 305 77 0 77 0 -12.9 0 -12.7 -12.9 12/15/2004 15:40:00 17.5 1.6 21.4 13.3 17 1.6 21 12.6 0.4 0 0.4 0.4 24 5 26 305 77 0 77 0 -12.8 0 -12.5 -12.9 12/15/2004 15:50:00 16.6 1.6 20.2 12.6 16.2 1.5 19.5 12.6 0.4 0 0.4 0.4 24 6 29 305 77 0 77 0 -12.7 0 -12.5 -12.9 12/15/2004 16:00:00 16.5 1.6 21 12.6 16.1 1.6 19.9 11.8 0.4 0 0.4 0.4 24 5 18 305 77 0 77 0 -12.7 0 -12.5 -12.9 12/15/2004 16:10:00 15.9 1.7 20.2 11.5 15.5 1.7 19.9 11.1 0.4 0 0.4 0.4 25 6 26 305 77 0 77 0 -12.8 0 -12.5 -12.9 12/15/2004 16:20:00 17.1 1.5 20.2 13.7 16.7 1.5 20.6 13.3 0.4 0 0.4 0.4 22 5 25 305 77 0 77 0 -12.8 0 -12.5 -12.9 12/15/2004 16:30:00 17.2 1.6 20.6 12.6 16.8 1.7 20.6 11.5 0.4 0 0.4 0.4 25 5 25 305 77 0 77 0 -12.9 0 -12.5 -12.9 12/15/2004 16:40:00 16.5 2 20.6 11.5 16.2 1.9 20.6 11.8 0.4 0 0.4 0.4 24 6 24 305 77 0 77 0 -12.9 0 -12.5 -13.1 12/15/2004 16:50:00 16.7 1.7 21 11.8 16.2 1.7 21 11.5 0.4 0 0.4 0.4 24 6 23 305 77 0 77 0 -12.9 0 -12.5 -12.9 12/15/2004 17:00:00 16.3 1.6 19.9 12.6 15.9 1.5 19.5 12.2 0.4 0 0.4 0.4 25 6 17 305 77 0 77 0 -12.8 0 -12.5 -12.9 12/15/2004 17:10:00 16.2 1.5 19.9 12.2 15.7 1.5 19.5 12.2 0.4 0 0.4 0.4 24 5 24 305 77 0 77 0 -12.7 0 -12.5 -12.9 12/15/2004 17:20:00 16 1.7 19.9 11.5 15.5 1.7 19.1 11.1 0.4 0 0.4 0.4 24 5 19 305 77 0 77 0 -12.6 0 -12.3 -12.9 12/15/2004 17:30:00 15.9 1.5 19.5 11.8 15.3 1.4 18.7 11.8 0.4 0 0.4 0.4 26 6 30 305 77 0 77 0 -12.6 0 -12.1 -12.7 12/15/2004 17:40:00 15.6 1.6 19.5 11.1 15.2 1.6 18.7 11.1 0.4 0 0.4 0.4 25 6 27 305 77 0 77 0 -12.4 0.1 -12.1 -12.5 12/15/2004 17:50:00 15.4 2 20.6 11.1 15 2.1 21.4 10.7 0.4 0 0.4 0.4 23 5 21 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 18:00:00 15.4 1.7 19.1 10.3 15.1 1.7 18.7 10.7 0.4 0 0.4 0.4 22 5 25 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 18:10:00 15.9 1.7 19.9 10.3 15.4 1.7 19.9 10.7 0.4 0 0.4 0.4 21 5 24 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 18:20:00 15.4 1.7 19.5 10.7 15 1.6 19.1 10.7 0.4 0 0.4 0.4 22 5 21 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 18:30:00 15.9 1.8 21 11.5 15.5 1.7 21 11.8 0.4 0 0.4 0.4 22 5 14 305 77 0 78 0 -12.3 0 -12.1 -12.5 12/15/2004 18:40:00 16.4 1.9 20.2 10.7 15.9 1.9 19.1 9.9 0.4 0 0.4 0.4 22 5 19 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/15/2004 18:50:00 15.4 1.6 19.5 11.5 15.1 1.7 19.1 11.1 0.4 0 0.4 0.4 21 5 21 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/15/2004 19:00:00 15.9 2 19.9 9.9 15.5 1.9 19.5 9.9 0.4 0 0.4 0.4 21 6 24 305 77 0 77 0 -12.5 0 -12.3 -12.5 12/15/2004 19:10:00 16.1 2.2 20.2 11.1 15.6 2.2 19.1 10.7 0.4 0 0.4 0.4 22 6 18 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/15/2004 19:20:00 15.5 1.6 18.3 11.5 15.1 1.5 17.9 11.1 0.4 0 0.4 0.4 22 5 33 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/15/2004 19:30:00 16.1 1.6 20.6 11.5 15.7 1.6 19.1 10.7 0.4 0 0.4 0.4 21 5 19 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/15/2004 19:40:00 16.2 1.7 19.9 11.5 15.9 1.7 19.5 11.8 0.4 0 0.4 0.4 21 5 19 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/15/2004 19:50:00 15.4 1.6 18.3 10.3 15 1.6 18.7 11.1 0.4 0 0.4 0.4 20 5 17 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/15/2004 20:00:00 15.1 1.7 19.1 10.7 14.8 1.6 19.1 11.1 0.4 0 0.4 0.4 22 6 18 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/15/2004 20:10:00 15.1 2.2 19.9 10.3 14.6 2.2 19.9 9.9 0.4 0 0.4 0.4 22 5 23 305 77 0 77 0 -12.5 0 -12.3 -12.5 12/15/2004 20:20:00 15.9 1.7 19.9 11.1 15.4 1.7 19.5 11.1 0.4 0 0.4 0.4 22 5 22 305 77 0 77 0 -12.5 0 -12.3 -12.5 12/15/2004 20:30:00 15.7 1.3 18.7 11.8 15.3 1.3 18.7 12.2 0.4 0 0.4 0.4 22 5 20 305 77 0 77 0 -12.5 0 -12.3 -12.5 12/15/2004 20:40:00 15 1.7 19.1 9.9 14.7 1.5 19.1 9.1 0.4 0 0.4 0.4 23 6 18 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/15/2004 20:50:00 14.2 1.7 18.7 9.5 14 1.6 17.9 10.3 0.4 0 0.4 0.4 22 6 22 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 21:00:00 15.8 1.9 19.5 9.9 15.4 1.9 19.5 9.9 0.4 0 0.4 0.4 23 5 24 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 21:10:00 15.8 1.4 19.1 12.2 15.2 1.4 18.3 11.8 0.4 0 0.4 0.4 27 5 24 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 21:20:00 15 1.7 19.1 11.1 14.6 1.7 19.1 10.7 0.4 0 0.4 0.4 21 6 22 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 21:30:00 15.7 1.7 18.7 11.1 15.3 1.7 19.1 11.1 0.4 0 0.4 0.4 21 6 18 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 21:40:00 15.7 1.8 19.5 10.7 15.3 1.7 18.7 10.7 0.4 0 0.4 0.4 21 6 16 305 77 0 77 0 -12.4 0.1 -12.1 -12.5 12/15/2004 21:50:00 15.2 1.6 19.9 11.1 14.9 1.7 19.9 10.7 0.4 0 0.4 0.4 20 6 21 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 22:00:00 15.4 1.4 18.3 12.2 15 1.4 18.3 11.5 0.4 0 0.4 0.4 19 5 19 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 22:10:00 14.9 1.7 17.9 10.7 14.6 1.7 18.3 10.7 0.4 0 0.4 0.4 16 6 12 305 77 0 77 0 -12.2 0 -12.1 -12.5 12/15/2004 22:20:00 14.5 1.6 17.6 10.3 14.1 1.5 17.6 10.7 0.4 0 0.4 0.4 15 5 18 305 77 0 78 0 -12.3 0 -12.1 -12.5 12/15/2004 22:30:00 13.8 1.6 17.2 9.9 13.4 1.5 16.8 9.9 0.4 0 0.4 0.4 16 6 13 305 77 0 78 0 -12.2 0 -12.1 -12.5 12/15/2004 22:40:00 14.8 1.4 17.9 9.9 14.5 1.5 17.6 10.7 0.4 0 0.4 0.4 16 6 26 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 22:50:00 14.7 1.5 18.3 10.7 14.5 1.5 18.3 11.1 0.4 0 0.4 0.4 18 6 17 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/15/2004 23:00:00 15.7 1.3 19.9 12.6 15.3 1.3 20.2 11.5 0.4 0 0.4 0.4 15 6 18 305 77 0 78 0 -12.4 0 -12.1 -12.5 12/15/2004 23:10:00 15.4 1.7 19.9 10.7 15.1 1.7 19.1 11.1 0.4 0 0.4 0.4 17 5 18 305 77 0 77 0 -12.5 0 -12.3 -12.5 12/15/2004 23:20:00 15.9 1.6 19.9 11.8 15.6 1.7 19.5 11.5 0.4 0 0.4 0.4 17 5 25 305 77 0 77 0 -12.5 0 -12.3 -12.5 12/15/2004 23:30:00 15.6 2.1 19.9 10.7 15.3 2.1 19.9 9.9 0.4 0 0.4 0.4 19 5 18 305 77 0 77 0 -12.5 0 -12.3 -12.5 12/15/2004 23:40:00 15 1.5 19.5 11.1 14.7 1.6 19.5 10.3 0.4 0 0.4 0.4 19 6 23 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/15/2004 23:50:00 14.3 1.7 18.7 10.7 13.9 1.7 18.3 10.3 0.4 0 0.4 0.4 21 7 21 305 77 0 77 0 -12.5 0 -12.3 -12.5 12/16/2004 00:00:00 15.3 1.9 20.6 10.7 15 1.8 19.5 10.7 0.4 0 0.4 0.4 21 6 18 305 77 0 77 0 -12.5 0 -12.1 -12.5 12/16/2004 00:10:00 15.7 2.5 21 9.5 15.1 2.3 20.2 9.5 0.4 0 0.4 0.4 25 7 21 305 77 0 77 0 -12.6 0 -12.5 -12.7 12/16/2004 00:20:00 19.4 2 23.3 14.1 18.8 2.1 23.3 12.6 0.4 0 0.4 0.4 22 6 26 305 77 0 77 0 -12.5 0 -12.5 -12.5 12/16/2004 00:30:00 20.3 2.5 24.8 13.7 19.5 2.3 24.8 13.3 0.4 0 0.4 0.4 22 6 25 305 77 0 77 0 -12.5 0 -12.3 -12.7 12/16/2004 00:40:00 20 2.4 24.8 14.1 19.5 2.3 23.7 14.1 0.4 0 0.4 0.4 22 5 24 305 77 0 77 0 -12.5 0 -12.3 -12.7 12/16/2004 00:50:00 18.6 2 22.9 13 18.2 2 22.6 12.6 0.4 0 0.4 0.4 21 6 18 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/16/2004 01:00:00 18.7 1.5 21.8 14.9 18.1 1.7 21.8 13.7 0.4 0 0.4 0.4 23 5 16 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/16/2004 01:10:00 16.7 1.9 21.8 12.2 16.2 1.7 21 11.1 0.4 0 0.4 0.4 23 6 30 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/16/2004 01:20:00 17.8 2.3 23.7 11.8 17.3 2.2 22.6 11.8 0.4 0 0.4 0.4 24 6 21 305 77 0 78 0 -12.3 0 -12.1 -12.5 12/16/2004 01:30:00 18.1 2.1 23.3 13.3 17.5 2 22.9 11.1 0.4 0 0.4 0.4 23 6 19 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/16/2004 01:40:00 18.5 1.8 22.6 12.6 17.8 1.9 21.8 13 0.4 0 0.4 0.4 21 6 15 305 77 0 77 0 -12.1 0 -12.1 -12.5 12/16/2004 01:50:00 18.1 2.2 22.9 12.2 17.5 2.1 22.9 12.2 0.4 0 0.4 0.4 24 6 17 305 77 0 78 0 -12 0 -11.9 -12.3 12/16/2004 02:00:00 18.4 1.9 22.9 14.1 17.8 2.1 23.3 13 0.4 0 0.4 0.4 24 5 26 305 78 0 78 0 -11.9 0 -11.7 -12.1 12/16/2004 02:10:00 17.4 2.2 21.8 12.2 16.9 2.1 21 11.5 0.4 0 0.4 0.4 23 6 28 305 78 0 78 0 -11.8 0 -11.7 -12.1 12/16/2004 02:20:00 14.1 1.8 18.7 9.1 14.1 1.8 18.3 9.5 0.4 0 0.4 0.4 14 6 29 305 78 0 78 0 -12.1 0.3 -11.5 -12.5 12/16/2004 02:30:00 14.7 1.7 19.9 10.7 14.5 1.7 18.7 10.7 0.4 0 0.4 0.4 15 6 19 305 77 0 77 0 -12.4 0 -12.1 -12.5 12/16/2004 02:40:00 14.6 2.1 21.4 10.3 14.3 2.1 20.6 9.5 0.4 0 0.4 0.4 16 5 17 305 77 0 77 0 -12.5 0 -12.1 -12.5 12/16/2004 02:50:00 14 1.9 18.3 10.3 13.7 1.8 17.9 9.5 0.4 0 0.4 0.4 18 6 18 305 77 0 77 0 -12.5 0 -12.3 -12.5 12/16/2004 03:00:00 14.5 1.6 18.7 10.7 14.3 1.6 19.5 10.3 0.4 0 0.4 0.4 19 7 19 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/16/2004 03:10:00 15.9 1.8 19.9 11.5 15.6 1.7 19.5 11.1 0.4 0 0.4 0.4 20 5 27 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/16/2004 03:20:00 16.2 1.5 20.2 11.8 15.9 1.5 18.7 11.8 0.4 0 0.4 0.4 16 5 11 305 77 0 78 0 -12.4 0 -12.1 -12.5 12/16/2004 03:30:00 15.4 1.7 19.1 10.7 15.2 1.7 18.7 11.1 0.4 0 0.4 0.4 15 6 21 305 78 0 77 0 -12.4 0.1 -12.1 -12.5 12/16/2004 03:40:00 14.8 1.8 19.1 10.3 14.5 1.8 18.7 9.9 0.4 0 0.4 0.4 16 5 20 305 78 0 78 0 -12.2 0 -12.1 -12.5 12/16/2004 03:50:00 15.3 1.7 19.5 11.1 15 1.7 19.1 10.7 0.4 0 0.4 0.4 18 6 18 305 78 0 78 0 -12.1 0 -11.7 -12.3 12/16/2004 04:00:00 14.6 1.8 18.7 9.9 14.4 1.8 18.7 9.5 0.4 0 0.4 0.4 16 5 13 305 78 0 78 0 -12.1 0 -12.1 -12.3 12/16/2004 04:10:00 13.4 1.7 18.7 9.9 13.3 1.7 17.9 9.9 0.4 0 0.4 0.4 16 6 21 305 78 0 77 0 -12 0 -11.9 -12.1 12/16/2004 04:20:00 14.7 1.6 17.6 10.7 14.6 1.7 18.3 10.3 0.4 0 0.4 0.4 15 5 21 305 77 0 78 0 -12.2 0 -12.1 -12.5 12/16/2004 04:30:00 15.4 1.7 19.5 10.7 15.1 1.7 19.1 10.7 0.4 0 0.4 0.4 15 5 20 305 77 0 77 0 -12.3 0 -12.1 -12.5 12/16/2004 04:40:00 16.2 1.7 20.6 11.8 15.9 1.7 19.9 11.5 0.4 0 0.4 0.4 13 5 17 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/16/2004 04:50:00 16.6 1.8 21 11.8 16.3 1.7 19.9 11.8 0.4 0 0.4 0.4 12 5 7 305 77 0 77 0 -12.4 0 -12.3 -12.5 12/16/2004 05:00:00 16.9 1.9 21.8 11.1 16.5 2 22.1 11.1 0.4 0 0.4 0.4 12 5 13 305 77 0 78 0 -12.4 0.1 -12.1 -12.5 12/16/2004 05:10:00 16.2 1.6 19.1 12.2 15.9 1.6 19.5 12.2 0.4 0 0.4 0.4 11 5 9 305 77 0 77 0 -12.4 0.1 -12.1 -12.7 12/16/2004 05:20:00 16.9 1.5 19.9 12.2 16.6 1.4 19.9 11.8 0.4 0 0.4 0.4 11 5 11 305 77 0 78 0 -12.6 0 -12.3 -12.7 12/16/2004 05:30:00 14.7 1.7 17.9 10.7 14.5 1.7 18.3 9.1 0.4 0 0.4 0.4 12 5 8 305 77 0 77 0 -12.5 0 -12.1 -12.7 12/16/2004 05:40:00 13.7 1.3 17.2 10.7 13.5 1.3 17.2 10.7 0.4 0 0.4 0.4 14 5 15 305 78 0 78 0 -12.3 0 -12.1 -12.5 12/16/2004 05:50:00 14.1 1.6 17.6 10.3 13.9 1.7 18.3 9.5 0.4 0 0.4 0.4 12 5 11 305 78 0 78 0 -12.3 0 -12.1 -12.5 12/16/2004 06:00:00 13.8 1.6 17.2 10.3 13.7 1.6 17.6 9.9 0.4 0 0.4 0.4 12 5 7 305 78 0 78 0 -12.2 0.1 -12.1 -12.5 12/16/2004 06:10:00 13 1.3 16.4 8.8 12.8 1.2 16.1 9.1 0.4 0 0.4 0.4 11 5 10 305 78 0 78 0 -12.1 0 -12.1 -12.3 12/16/2004 06:20:00 12.7 1.3 16.4 8.8 12.6 1.4 16.4 9.1 0.4 0 0.4 0.4 8 5 9 305 78 0 78 0 -12.1 0 -12.1 -12.3 12/16/2004 06:30:00 12.3 1.3 16.1 8.4 12.2 1.3 15.3 8.4 0.4 0 0.4 0.4 12 5 13 305 78 0 78 0 -12 0 -11.9 -12.1 12/16/2004 06:40:00 13.5 1.9 18.3 9.5 13.2 2 18.3 9.1 0.4 0 0.4 0.4 14 6 20 305 78 0 79 0 -11.6 0.1 -11.3 -12.1 12/16/2004 06:50:00 14.1 1.4 16.8 9.9 14 1.4 16.8 10.7 0.4 0 0.4 0.4 9 5 14 305 78 0 79 0 -11.8 0.1 -11.5 -12.1 12/16/2004 07:00:00 16.1 2 20.6 11.5 15.8 2 20.6 10.7 0.4 0 0.4 0.4 15 5 21 305 78 0 78 0 -11.9 0 -11.5 -12.1 12/16/2004 07:10:00 15 1.3 17.9 11.5 14.9 1.3 17.6 11.5 0.4 0 0.4 0.4 13 5 17 305 78 0 77 0 -12 0 -11.7 -12.1 12/16/2004 07:20:00 15.1 1.7 19.1 11.1 15 1.7 19.1 11.1 0.4 0 0.4 0.4 14 5 10 305 78 0 78 0 -12 0 -11.7 -12.1 12/16/2004 07:30:00 15.3 1.6 19.5 10.7 15 1.5 18.3 10.7 0.4 0 0.4 0.4 15 5 19 305 78 0 78 0 -12 0.1 -11.5 -12.3 12/16/2004 07:40:00 15.7 1.7 20.6 11.1 15.4 1.7 20.2 11.5 0.4 0 0.4 0.4 15 6 6 305 78 0 78 0 -11.9 0 -11.7 -12.1 12/16/2004 07:50:00 13.9 1.9 19.5 10.3 13.7 1.9 19.5 9.5 0.4 0 0.4 0.4 13 5 14 305 78 0 78 0 -11.9 0 -11.7 -12.1 12/16/2004 08:00:00 14.7 1.6 17.9 10.3 14.5 1.8 17.9 9.5 0.4 0 0.4 0.4 15 5 9 305 78 0 78 0 -11.8 0.1 -11.5 -12.1 12/16/2004 08:10:00 13 1.5 16.4 9.1 13 1.5 15.6 9.1 0.4 0 0.4 0.4 7 5 11 305 78 0 78 0 -12.2 0.3 -11.5 -12.5 12/16/2004 08:20:00 13.5 1.1 17.2 10.7 13.4 1.2 16.8 10.3 0.4 0 0.4 0.4 6 5 10 305 78 0 78 0 -12.6 0 -12.3 -12.7 12/16/2004 08:30:00 13.3 1.5 16.4 8.8 13.2 1.5 16.8 8.8 0.4 0 0.4 0.4 9 5 7 305 78 0 78 0 -12.5 0 -12.3 -12.5 12/16/2004 08:40:00 12.6 1.3 15.6 9.5 12.6 1.3 15.6 9.1 0.4 0 0.4 0.4 5 5 7 305 78 0 78 0 -12.6 0 -12.3 -12.9 12/16/2004 08:50:00 12.7 1.4 16.1 8.8 12.6 1.4 16.4 8.8 0.4 0 0.4 0.4 5 5 0 305 77 0 77 0 -12.8 0 -12.5 -12.9 12/16/2004 09:00:00 12.5 1.3 15.3 8.4 12.4 1.3 15.6 9.1 0.4 0 0.4 0.4 7 5 3 305 77 0 77 0 -12.6 0 -12.3 -12.9 12/16/2004 09:10:00 11.8 1 14.9 8.4 11.7 1.1 13.7 8.4 0.4 0 0.4 0.4 7 5 9 305 77 0 77 0 -12.5 0 -12.1 -12.7 12/16/2004 09:20:00 14.9 2.4 20.2 9.9 14.6 2.3 20.6 9.5 0.4 0 0.4 0.4 19 8 13 305 78 0 78 0 -11.8 0.2 -11.3 -12.5 12/16/2004 09:30:00 15.6 1.7 20.6 11.5 15.2 1.7 19.5 10.7 0.4 0 0.4 0.4 22 5 17 305 78 0 78 0 -11.5 0 -11.3 -11.7 12/16/2004 09:40:00 16 1.7 21.4 11.5 15.8 1.7 22.1 11.1 0.4 0 0.4 0.4 21 5 19 305 78 0 78 0 -11.5 0 -11.3 -11.7 12/16/2004 09:50:00 16.3 1.6 19.9 12.2 16 1.6 19.9 12.2 0.4 0 0.4 0.4 20 5 23 305 78 0 78 0 -11.5 0 -11.3 -11.7 12/16/2004 10:00:00 15.3 1.7 19.1 10.7 15 1.8 18.3 10.3 0.4 0 0.4 0.4 23 6 18 305 78 0 78 0 -11.5 0 -11.3 -11.7 12/16/2004 10:10:00 14.9 1.4 18.3 11.5 14.5 1.5 18.7 10.7 0.4 0 0.4 0.4 20 5 19 305 79 0 79 0 -11.4 0 -11.3 -11.5 12/16/2004 10:20:00 15.1 1.5 18.7 11.1 14.7 1.6 18.7 10.7 0.4 0 0.4 0.4 19 5 17 305 78 0 79 0 -11.5 0 -11.3 -11.7 12/16/2004 10:30:00 14.9 2.1 19.1 9.5 14.8 1.9 18.7 9.9 0.4 0 0.4 0.4 21 5 24 305 78 0 78 0 -11.5 0 -11.3 -11.7 12/16/2004 10:40:00 15.8 1.7 20.6 11.5 15.4 1.7 20.2 11.1 0.4 0 0.4 0.4 23 6 29 305 78 0 78 0 -11.5 0 -11.3 -11.7 12/16/2004 10:50:00 15.3 1.5 19.5 11.5 15 1.5 19.9 11.1 0.4 0 0.4 0.4 24 6 20 305 78 0 78 0 -11.5 0 -11.3 -11.7 12/16/2004 11:00:00 14.8 1.7 19.5 11.5 14.6 1.7 18.7 10.7 0.4 0 0.4 0.4 22 6 17 305 79 0 79 0 -11.5 0 -11.3 -11.5 12/16/2004 11:10:00 14.3 2 19.1 8.8 14.1 2 18.7 9.5 0.4 0 0.4 0.4 22 6 27 305 79 0 79 0 -11.4 0 -11.3 -11.5 12/16/2004 11:20:00 14.8 1.3 17.9 11.1 14.7 1.4 17.6 10.7 0.4 0 0.4 0.4 22 5 29 305 79 0 78 0 -11.2 0 -11.1 -11.3 12/16/2004 11:30:00 14.6 1.6 18.7 10.7 14.3 1.7 18.3 10.3 0.4 0 0.4 0.4 20 6 28 305 79 0 79 0 -11.2 0 -11.1 -11.3 12/16/2004 11:40:00 15.6 1.5 19.5 12.2 15.2 1.5 19.1 11.5 0.4 0 0.4 0.4 21 5 23 305 79 0 79 0 -11.3 0 -11.1 -11.5 12/16/2004 11:50:00 13.1 2.3 17.6 8.8 13 2.1 17.9 8 0.4 0 0.4 0.4 15 8 22 305 79 0 79 0 -11.5 0.3 -11.1 -12.3 12/16/2004 12:00:00 11.6 1.4 15.6 8 11.4 1.4 14.9 8.4 0.4 0 0.4 0.4 10 6 7 305 78 0 78 0 -12.4 0.1 -12.1 -12.5 12/16/2004 12:10:00 12.7 2.3 17.9 8.4 12.4 2.1 18.3 8.4 0.4 0 0.4 0.4 17 7 16 305 78 0 78 0 -11.6 0.2 -11.3 -12.1 12/16/2004 12:20:00 11.7 1 13.7 9.1 11.7 1 14.5 9.1 0.4 0 0.4 0.4 10 5 14 305 78 0 78 0 -12 0.2 -11.5 -12.3 12/16/2004 12:30:00 11.9 1.2 14.5 8.8 11.7 1.2 14.5 8.8 0.4 0 0.4 0.4 13 5 12 305 78 0 78 0 -12.1 0 -12.1 -12.3 12/16/2004 12:40:00 11 1 13.3 8.4 11 1.1 13.7 8 0.4 0 0.4 0.4 10 5 9 305 78 0 78 0 -12.2 0.1 -11.9 -12.5 12/16/2004 12:50:00 11.8 1.2 14.5 8.8 11.5 1.2 14.1 9.1 0.4 0 0.4 0.4 9 5 17 305 78 0 78 0 -12.4 0.1 -12.1 -12.5 12/16/2004 13:00:00 11.6 1.2 14.5 8 11.4 1.2 14.1 8 0.4 0 0.4 0.4 9 5 9 305 78 0 78 0 -12.3 0 -12.1 -12.5 12/16/2004 13:10:00 10.9 1.3 14.1 8 10.8 1.2 13.7 7.6 0.4 0 0.4 0.4 9 5 18 305 78 0 78 0 -12.4 0.1 -12.1 -12.5 12/16/2004 13:20:00 11.7 1.2 14.1 8.4 11.5 1.2 14.5 8 0.4 0 0.4 0.4 11 5 9 305 78 0 79 0 -12.1 0.1 -11.7 -12.5 12/16/2004 13:30:00 11.6 1.4 14.9 8.4 11.6 1.4 14.5 8 0.4 0 0.4 0.4 8 6 8 305 78 0 78 0 -12.2 0 -11.9 -12.5 12/16/2004 13:40:00 12.2 1.2 15.3 8.8 12 1.3 14.5 8 0.4 0 0.4 0.4 9 5 7 305 78 0 78 0 -12.3 0 -12.1 -12.5 12/16/2004 13:50:00 11.5 1.1 13.7 7.6 11.5 1.1 13.7 8 0.4 0 0.4 0.4 10 6 4 305 78 0 78 0 -12.2 0 -12.1 -12.5 12/16/2004 14:00:00 12.5 1.3 15.3 8.8 12.3 1.5 15.3 8.8 0.4 0 0.4 0.4 10 5 13 305 78 0 78 0 -12.3 0 -12.1 -12.5 12/16/2004 14:10:00 12 1.6 15.6 8 11.9 1.6 15.6 8 0.4 0 0.4 0.4 8 6 9 305 78 0 78 0 -12.3 0.1 -12.1 -12.5 12/16/2004 14:20:00 11.3 1.2 14.1 8 11.2 1.1 14.1 8.4 0.4 0 0.4 0.4 10 6 11 305 78 0 78 0 -12.3 0 -12.1 -12.5 12/16/2004 14:30:00 11.1 1.3 14.9 8 11.1 1.3 14.5 8 0.4 0 0.4 0.4 10 6 14 305 78 0 78 0 -12.2 0 -11.9 -12.5 12/16/2004 14:40:00 11.5 1.5 14.5 7.6 11.5 1.3 14.5 8.4 0.4 0 0.4 0.4 8 6 5 305 78 0 78 0 -12.2 0.1 -11.7 -12.5 12/16/2004 14:50:00 10.1 1.3 13.7 7.2 10 1.3 13.7 6.5 0.4 0 0.4 0.4 10 6 11 305 78 0 78 0 -12 0.1 -11.7 -12.5 12/16/2004 15:00:00 10.2 1.3 13.7 6.8 10.1 1.2 13.3 7.2 0.4 0 0.4 0.4 11 6 4 305 79 0 79 0 -11.6 0.1 -11.5 -11.9 12/16/2004 15:10:00 10 1.1 13.3 7.2 9.9 1.2 13 6.5 0.4 0 0.4 0.4 14 5 15 305 79 0 79 0 -11.4 0.1 -10.9 -11.7 12/16/2004 15:20:00 10.1 1.5 14.9 7.2 9.9 1.5 14.1 6.5 0.4 0 0.4 0.4 14 6 15 305 79 0 79 0 -11 0.1 -10.4 -11.3 12/16/2004 15:30:00 13.2 1.5 16.4 8.8 12.9 1.5 16.1 8.4 0.4 0 0.4 0.4 17 5 19 305 80 0 80 0 -10.5 0 -10.4 -10.9 12/16/2004 15:40:00 12.3 1.6 17.2 8 12.1 1.7 16.8 7.6 0.4 0 0.4 0.4 19 6 21 305 80 0 80 0 -10.4 0 -10.2 -10.4 12/16/2004 15:50:00 12.2 1.5 16.1 8 12 1.5 15.3 7.6 0.4 0 0.4 0.4 20 6 22 305 80 0 80 0 -10.3 0 -10 -10.4 12/16/2004 16:00:00 11.6 1.7 16.4 8 11.4 1.7 16.1 8.4 0.4 0 0.4 0.4 21 6 15 305 80 0 80 0 -10.3 0 -10 -10.4 12/16/2004 16:10:00 13.9 1.7 17.6 9.1 13.6 1.7 17.2 8.8 0.4 0 0.4 0.4 21 5 22 305 80 0 80 0 -10.3 0 -10 -10.4 12/16/2004 16:20:00 13.1 1.6 17.2 9.9 12.9 1.5 17.6 9.5 0.4 0 0.4 0.4 20 5 24 305 80 0 80 0 -10.3 0 -10 -10.4 12/16/2004 16:30:00 13.8 1.7 17.9 9.1 13.5 1.6 17.6 9.5 0.4 0 0.4 0.4 21 6 22 305 80 0 80 0 -10.3 0 -10 -10.4 12/16/2004 16:40:00 13.7 1.4 16.8 9.5 13.3 1.4 16.4 9.9 0.4 0 0.4 0.4 22 6 29 305 79 0 80 0 -10.3 0 -10 -10.4 12/16/2004 16:50:00 12.5 1.5 16.4 9.1 12.2 1.5 16.4 8.8 0.4 0 0.4 0.4 21 5 12 305 79 0 80 0 -10.2 0 -10 -10.4 12/16/2004 17:00:00 14.5 1.7 18.3 9.5 14.2 1.7 18.3 9.9 0.4 0 0.4 0.4 24 6 18 305 79 0 79 0 -10.2 0.1 -9.8 -10.4 12/16/2004 17:10:00 13.8 1.5 17.6 9.1 13.5 1.6 17.2 8.8 0.4 0 0.4 0.4 22 6 32 305 79 0 79 0 -10.1 0 -9.8 -10.2 12/16/2004 17:20:00 13.6 1.5 16.8 10.3 13.2 1.5 16.4 9.9 0.4 0 0.4 0.4 25 6 23 305 79 0 79 0 -10.1 0 -9.6 -10.2 12/16/2004 17:30:00 13.2 1.8 17.6 8.8 13 1.8 17.9 8.4 0.4 0 0.4 0.4 26 6 21 305 79 0 79 0 -10 0 -9.6 -10.2 12/16/2004 17:40:00 13.8 1.7 17.2 9.9 13.4 1.7 17.9 9.9 0.4 0 0.4 0.4 25 6 21 305 79 0 79 0 -10 0 -9.6 -10 12/16/2004 17:50:00 13 1.5 16.1 8.4 12.6 1.6 16.1 8 0.4 0 0.4 0.4 25 6 20 305 79 0 79 0 -9.9 0 -9.6 -10 12/16/2004 18:00:00 13 1.7 16.4 8 12.6 1.7 16.1 8 0.4 0 0.4 0.4 25 6 31 305 79 0 79 0 -9.9 0 -9.6 -10 12/16/2004 18:10:00 12.1 1.6 15.6 8.8 11.8 1.7 16.1 7.6 0.4 0 0.4 0.4 25 6 19 305 79 0 79 0 -10 0 -9.6 -10 12/16/2004 18:20:00 11.6 1.3 14.9 8.4 11.3 1.2 14.9 8.8 0.4 0 0.4 0.4 24 6 27 305 79 0 79 0 -9.9 0 -9.6 -10 12/16/2004 18:30:00 11.3 1.4 14.9 7.6 11 1.3 14.5 7.6 0.4 0 0.4 0.4 24 6 25 305 79 0 79 0 -9.9 0 -9.6 -10 12/16/2004 18:40:00 11.5 1.6 14.9 8 11.3 1.7 14.5 7.2 0.4 0 0.4 0.4 24 6 18 305 79 0 79 0 -9.9 0 -9.6 -10 12/16/2004 18:50:00 12.9 1.5 16.4 8.8 12.6 1.6 16.8 8.8 0.4 0 0.4 0.4 24 5 24 305 79 0 79 0 -9.8 0 -9.6 -10 12/16/2004 19:00:00 12.4 1.5 16.1 8.8 12.1 1.5 15.6 8.8 0.4 0 0.4 0.4 24 6 31 305 79 0 79 0 -9.8 0 -9.4 -10 12/16/2004 19:10:00 13.4 1.7 16.8 9.1 12.9 1.7 16.4 8.4 0.4 0 0.4 0.4 26 6 16 305 79 0 79 0 -9.8 0 -9.4 -9.8 12/16/2004 19:20:00 12.7 1.3 15.6 9.5 12.2 1.3 15.6 9.5 0.4 0 0.4 0.4 26 6 25 305 79 0 79 0 -9.8 0 -9.4 -9.8 12/16/2004 19:30:00 13.2 1.7 16.8 9.5 12.8 1.8 16.4 8.4 0.4 0 0.4 0.4 26 6 21 305 79 0 79 0 -9.7 0 -9.6 -9.8 12/16/2004 19:40:00 12.5 1.7 17.2 7.6 12.1 1.6 16.8 8.4 0.4 0 0.4 0.4 25 6 34 305 79 0 79 0 -9.6 0 -9.4 -9.8 12/16/2004 19:50:00 13.2 1.9 17.2 8.8 12.9 1.7 16.8 8.8 0.4 0 0.4 0.4 25 6 29 305 79 0 79 0 -9.6 0 -9.4 -9.6 12/16/2004 20:00:00 13.6 1.5 17.2 9.5 13.3 1.5 16.8 9.5 0.4 0 0.4 0.4 24 6 26 305 79 0 79 0 -9.5 0 -9.2 -9.6 12/16/2004 20:10:00 10.3 1.7 16.4 6.8 10.3 1.7 16.8 7.2 0.4 0 0.4 0.4 12 7 31 305 79 0 79 0 -10.1 0.4 -9.2 -10.9 12/16/2004 20:20:00 10.4 0.9 12.6 8.4 10.3 1 13.3 7.6 0.4 0 0.4 0.4 11 5 12 305 78 0 78 0 -10.7 0.1 -10.4 -10.9 12/16/2004 20:30:00 10.2 1 12.2 7.2 10.1 1 12.6 7.2 0.4 0 0.4 0.4 12 5 12 305 78 0 78 0 -10.8 0 -10.4 -11.1 12/16/2004 20:40:00 10.3 1.1 12.6 7.6 10.1 1 12.6 7.6 0.4 0 0.4 0.4 13 5 13 305 78 0 78 0 -10.5 0 -10.4 -10.9 12/16/2004 20:50:00 10.5 1.1 13.3 7.6 10.2 1.1 13 7.6 0.4 0 0.4 0.4 15 5 12 305 78 0 78 0 -10.3 0 -10 -10.4 12/16/2004 21:00:00 10.4 1.4 14.1 7.6 10.2 1.3 13.7 7.6 0.4 0 0.4 0.4 18 6 21 305 78 0 78 0 -10.3 0 -10 -10.4 12/16/2004 21:10:00 10.5 1.1 13 7.2 10.4 1.2 13.3 6.8 0.4 0 0.4 0.4 20 7 19 305 78 0 78 0 -10.2 0 -9.8 -10.4 12/16/2004 21:20:00 10.3 1.2 13.3 7.2 10.1 1.2 13 7.2 0.4 0 0.4 0.4 20 6 19 305 78 0 78 0 -9.9 0 -9.6 -10 12/16/2004 21:30:00 11.1 1.5 15.6 7.6 10.7 1.5 15.6 7.2 0.4 0 0.4 0.4 22 7 27 305 78 0 78 0 -9.8 0 -9.6 -10 12/16/2004 21:40:00 11.1 1.3 14.5 8.4 10.9 1.3 13.7 8 0.4 0 0.4 0.4 24 7 29 305 78 0 78 0 -9.7 0 -9.4 -9.8 12/16/2004 21:50:00 12.3 1.7 16.4 8.4 11.9 1.7 15.6 8 0.4 0 0.4 0.4 28 6 29 305 78 0 79 0 -9.5 0 -9.2 -9.6 12/16/2004 22:00:00 13.2 1.3 16.4 9.1 12.8 1.3 16.8 9.1 0.4 0 0.4 0.4 27 6 19 305 78 0 79 0 -9.5 0 -9.2 -9.6 12/16/2004 22:10:00 13.4 1.5 17.2 10.3 12.9 1.5 17.2 9.9 0.4 0 0.4 0.4 26 6 27 305 78 0 78 0 -9.4 0 -9 -9.6 12/16/2004 22:20:00 13 1.5 16.1 9.9 12.5 1.5 16.1 9.1 0.4 0 0.4 0.4 27 6 24 305 79 0 79 0 -9.4 0 -9 -9.6 12/16/2004 22:30:00 13.4 1.5 18.3 10.3 12.8 1.5 18.3 9.5 0.4 0 0.4 0.4 28 6 29 305 79 0 79 0 -9.4 0 -9 -9.6 12/16/2004 22:40:00 13.1 1.7 17.2 8.8 12.5 1.6 16.8 8.8 0.4 0 0.4 0.4 27 6 33 305 79 0 79 0 -9.4 0 -9.2 -9.6 12/16/2004 22:50:00 13.4 2 17.6 8.8 13 1.8 17.2 8.8 0.4 0 0.4 0.4 25 6 25 305 80 0 80 0 -9.3 0 -9 -9.6 12/16/2004 23:00:00 12.7 1.5 16.8 9.1 12.4 1.5 16.1 8.8 0.4 0 0.4 0.4 25 6 26 305 80 0 80 0 -9.3 0 -9 -9.4 12/16/2004 23:10:00 12.5 1.3 16.1 8.8 12.1 1.3 14.9 8.4 0.4 0 0.4 0.4 25 6 21 305 80 0 80 0 -9.3 0 -9 -9.4 12/16/2004 23:20:00 13 1.7 16.8 9.5 12.5 1.6 16.4 8.4 0.4 0 0.4 0.4 25 5 21 305 80 0 80 0 -9.3 0 -9 -9.4 12/16/2004 23:30:00 12.8 1.3 17.2 9.1 12.6 1.3 16.1 9.1 0.4 0 0.4 0.4 27 6 29 305 80 0 80 0 -9.3 0 -9 -9.4 12/16/2004 23:40:00 14.4 1.5 17.6 9.9 14 1.5 17.9 9.9 0.4 0 0.4 0.4 26 5 21 305 80 0 80 0 -9.3 0 -9 -9.4 12/16/2004 23:50:00 14.1 1.4 17.2 9.9 13.7 1.4 17.2 9.5 0.4 0 0.4 0.4 26 5 22 305 80 0 80 0 -9.3 0 -9 -9.4 12/17/2004 00:00:00 10.8 1.6 16.4 8 10.7 1.6 16.4 8 0.4 0 0.4 0.4 19 6 24 305 80 0 80 0 -9.7 0.2 -8.8 -10 12/17/2004 00:10:00 9.8 1 12.2 7.2 9.7 1 12.2 7.2 0.4 0 0.4 0.4 19 6 19 305 80 0 80 0 -9.9 0 -9.6 -10 12/17/2004 00:20:00 10.4 1.2 14.1 8 10.2 1.2 13.3 7.6 0.4 0 0.4 0.4 22 6 26 305 80 0 80 0 -9.8 0.1 -9.4 -10 12/17/2004 00:30:00 10.9 1.2 14.5 8 10.7 1.2 14.9 8 0.4 0 0.4 0.4 23 6 20 305 80 0 80 0 -9.5 0.1 -9 -9.8 12/17/2004 00:40:00 11.8 1.3 14.5 7.6 11.6 1.2 14.9 8.4 0.4 0 0.4 0.4 25 6 27 305 80 0 80 0 -9.3 0 -9 -9.6 12/17/2004 00:50:00 10.8 1.4 14.1 7.6 10.6 1.4 14.1 7.6 0.4 0 0.4 0.4 27 6 21 305 80 0 80 0 -9.3 0 -9 -9.4 12/17/2004 01:00:00 11.5 1.3 14.5 8.4 11.2 1.3 14.5 8.4 0.4 0 0.4 0.4 27 5 28 305 80 0 81 0 -9.2 0 -9 -9.2 12/17/2004 01:10:00 11.8 1.2 14.5 8.8 11.5 1.3 14.1 8 0.4 0 0.4 0.4 27 5 22 305 80 0 80 0 -9.2 0 -8.8 -9.2 12/17/2004 01:20:00 11.6 1.2 14.5 8.4 11.4 1.3 14.5 8.8 0.4 0 0.4 0.4 26 6 40 305 80 0 80 0 -9.2 0 -8.8 -9.2 12/17/2004 01:30:00 11.7 1.3 15.6 8.8 11.4 1.3 15.6 8.4 0.4 0 0.4 0.4 24 6 23 305 81 0 82 0 -9.2 0 -9 -9.2 12/17/2004 01:40:00 10.8 1.3 14.5 7.6 10.5 1.3 14.5 7.6 0.4 0 0.4 0.4 24 6 28 305 82 0 82 0 -9.2 0.1 -8.8 -9.2 12/17/2004 01:50:00 10.5 1.5 14.1 6.8 10.3 1.5 13.7 6.8 0.4 0 0.4 0.4 23 6 27 305 82 0 82 0 -9.1 0.1 -8.8 -9.2 12/17/2004 02:00:00 11.1 1.1 14.5 7.6 10.9 1.1 13.7 8 0.4 0 0.4 0.4 20 5 17 305 82 0 82 0 -9.1 0.1 -8.8 -9.2 12/17/2004 02:10:00 11.2 1.2 14.1 8.4 11 1.3 14.5 8.4 0.4 0 0.4 0.4 21 5 19 305 82 0 82 0 -9.1 0.1 -8.8 -9.2 12/17/2004 02:20:00 12.1 1.5 16.1 8.4 11.9 1.5 16.1 8.4 0.4 0 0.4 0.4 21 6 21 305 82 0 82 0 -9.2 0 -8.8 -9.2 12/17/2004 02:30:00 12.1 1.1 14.5 8.8 11.8 1.1 14.9 9.5 0.4 0 0.4 0.4 22 6 19 305 82 0 82 0 -9.2 0 -8.8 -9.4 12/17/2004 02:40:00 12 1.3 15.3 8.4 11.8 1.3 14.9 8.4 0.4 0 0.4 0.4 23 5 19 305 82 0 82 0 -9.2 0 -8.8 -9.2 12/17/2004 02:50:00 11.2 1.3 14.1 8 11 1.3 14.1 7.6 0.4 0 0.4 0.4 24 6 19 305 82 0 82 0 -9.1 0 -8.8 -9.2 12/17/2004 03:00:00 11.9 1.2 14.9 8.8 11.7 1.2 14.9 8.4 0.4 0 0.4 0.4 24 5 26 305 81 0 82 0 -9.1 0.1 -8.8 -9.2 12/17/2004 03:10:00 11.5 1.3 15.3 8.4 11.3 1.3 15.3 8 0.4 0 0.4 0.4 26 6 21 305 81 0 82 0 -9.1 0.1 -8.8 -9.2 12/17/2004 03:20:00 11.7 1.3 14.9 8.4 11.5 1.3 15.3 7.6 0.4 0 0.4 0.4 25 6 21 305 82 0 82 0 -9.1 0.1 -8.8 -9.2 12/17/2004 03:30:00 11.4 1 14.1 8.8 11.2 1 14.1 8.4 0.4 0 0.4 0.4 26 5 29 305 81 0 82 0 -9.1 0.1 -8.8 -9.2 12/17/2004 03:40:00 10.8 1.2 14.5 7.6 10.7 1.2 14.9 8 0.4 0 0.4 0.4 26 6 23 305 81 0 82 0 -9 0.1 -8.8 -9.2 12/17/2004 03:50:00 11.3 1.5 14.5 8.4 11.2 1.5 14.9 8.4 0.4 0 0.4 0.4 27 6 25 305 81 0 82 0 -9 0.1 -8.8 -9.2 12/17/2004 04:00:00 11.1 1.4 14.9 7.2 11 1.5 14.9 7.2 0.4 0 0.4 0.4 29 7 33 305 81 0 82 0 -9 0 -8.8 -9.2 12/17/2004 04:10:00 10.4 1.4 14.1 7.2 10.3 1.4 13.7 7.2 0.4 0 0.4 0.4 26 6 31 305 82 0 82 0 -9 0 -8.8 -9.2 12/17/2004 04:20:00 11.6 1.5 14.9 7.2 11.4 1.5 14.5 7.2 0.4 0 0.4 0.4 27 6 29 305 81 0 82 0 -8.9 0 -8.6 -9.2 12/17/2004 04:30:00 12 1.7 15.3 7.6 11.9 1.6 16.1 7.6 0.4 0 0.4 0.4 27 6 27 305 81 0 82 0 -8.9 0 -8.6 -9.2 12/17/2004 04:40:00 11.9 1.5 15.3 8 11.7 1.5 14.9 8.4 0.4 0 0.4 0.4 28 6 37 305 81 0 81 0 -8.9 0 -8.6 -9.2 12/17/2004 04:50:00 12.5 1.3 14.9 9.1 12.4 1.3 15.6 9.5 0.4 0 0.4 0.4 27 6 25 305 81 0 82 0 -8.9 0 -8.6 -9.2 12/17/2004 05:00:00 11.6 1.3 14.5 8.4 11.5 1.5 14.5 8 0.4 0 0.4 0.4 30 5 28 305 81 0 82 0 -8.9 0 -8.6 -9.2 12/17/2004 05:10:00 11.4 1.3 14.5 8.4 11.3 1.3 14.5 8.4 0.4 0 0.4 0.4 28 6 32 305 81 0 81 0 -8.9 0 -8.6 -9.2 12/17/2004 05:20:00 10.7 1.4 14.1 7.2 10.6 1.3 14.1 7.6 0.4 0 0.4 0.4 27 6 24 305 81 0 82 0 -8.9 0 -8.6 -9.2 12/17/2004 05:30:00 11.9 1.3 15.3 8.4 11.8 1.3 14.9 8 0.4 0 0.4 0.4 25 6 23 305 81 0 82 0 -9 0 -8.8 -9.2 12/17/2004 05:40:00 10.4 1.2 13 7.2 10.4 1.2 13 7.2 0.4 0 0.4 0.4 28 6 24 305 81 0 81 0 -9 0 -8.8 -9.2 12/17/2004 05:50:00 10.8 1.3 14.5 8 10.6 1.2 14.1 8 0.4 0 0.4 0.4 28 6 27 305 81 0 81 0 -9 0 -8.8 -9.2 12/17/2004 06:00:00 11.6 1.4 15.3 8.4 11.5 1.3 15.3 8.8 0.4 0 0.4 0.4 27 6 27 305 81 0 81 0 -9 0 -8.8 -9.2 12/17/2004 06:10:00 11.2 1.5 14.9 8 11.1 1.5 14.1 7.6 0.4 0 0.4 0.4 29 6 37 305 81 0 81 0 -9 0.1 -8.8 -9.2 12/17/2004 06:20:00 12 1.4 15.3 8.4 11.8 1.5 15.3 8 0.4 0 0.4 0.4 29 6 33 305 81 0 81 0 -9.1 0.1 -8.8 -9.2 12/17/2004 06:30:00 12 1.2 14.9 9.1 11.8 1.2 14.9 8.4 0.4 0 0.4 0.4 29 6 32 305 81 0 81 0 -9 0.1 -8.8 -9.2 12/17/2004 06:40:00 11.3 1.4 14.5 8 11.2 1.3 14.1 7.2 0.4 0 0.4 0.4 31 6 37 305 81 0 81 0 -9 0 -8.8 -9.2 12/17/2004 06:50:00 11.6 1.3 14.9 8.8 11.5 1.3 15.3 8.4 0.4 0 0.4 0.4 32 5 35 305 81 0 80 0 -9 0.1 -8.8 -9.2 12/17/2004 07:00:00 11.8 1.3 14.5 8.8 11.6 1.2 14.9 8.8 0.4 0 0.4 0.4 29 5 23 305 81 0 81 0 -9.1 0.1 -8.8 -9.2 12/17/2004 07:10:00 12.2 1.2 14.9 9.1 12.1 1.2 14.9 9.1 0.4 0 0.4 0.4 28 5 23 305 80 0 81 0 -9.1 0.1 -8.8 -9.2 12/17/2004 07:20:00 12.2 1.3 14.9 8.8 12.1 1.3 14.9 9.1 0.4 0 0.4 0.4 26 5 26 305 80 0 81 0 -9.1 0.1 -8.8 -9.2 12/17/2004 07:30:00 11.5 1.1 14.1 8 11.3 1.2 14.1 8.4 0.4 0 0.4 0.4 24 6 23 305 80 0 80 0 -9.1 0.1 -8.8 -9.2 12/17/2004 07:40:00 10.3 1.3 13.7 7.2 10.1 1.3 13.3 6.8 0.4 0 0.4 0.4 26 7 31 305 80 0 80 0 -9 0.1 -8.8 -9.2 12/17/2004 07:50:00 11.2 1.2 13.7 7.6 11.1 1.2 14.1 7.6 0.4 0 0.4 0.4 27 5 33 305 80 0 80 0 -9 0.1 -8.8 -9.2 12/17/2004 08:00:00 10.7 1.3 13.3 7.2 10.6 1.2 13.3 7.6 0.4 0 0.4 0.4 29 7 28 305 80 0 80 0 -9 0 -8.6 -9.2 12/17/2004 08:10:00 10.8 1.7 14.1 6.8 10.7 1.7 14.5 6.5 0.4 0 0.4 0.4 36 0 36 305 80 0 80 0 -8.8 0 -8.6 -9 12/17/2004 08:20:00 10.6 1.2 13.7 8 10.6 1.2 13.3 7.6 0.4 0 0.4 0.4 36 0 36 305 80 0 80 0 -8.8 0 -8.4 -9 12/17/2004 08:30:00 9.6 1 11.8 6.8 9.4 1.1 12.6 6.8 0.4 0 0.4 0.4 36 0 36 305 80 0 80 0 -8.7 0 -8.4 -8.8 12/17/2004 08:40:00 10 1 11.8 8 9.8 1 12.6 7.2 0.4 0 0.4 0.4 36 0 36 305 80 0 80 0 -8.7 0 -8.4 -8.8 12/17/2004 08:50:00 10.9 1.3 13.7 7.6 10.9 1.3 14.1 7.6 0.4 0 0.4 0.4 36 0 36 305 80 0 80 0 -8.7 0 -8.4 -8.8 12/17/2004 09:00:00 9.9 1.1 13 7.2 9.8 1 12.6 7.2 0.4 0 0.4 0.4 36 0 36 305 80 0 80 0 -8.6 0.1 -8.4 -8.8 12/17/2004 09:10:00 9.5 1.2 12.6 6.8 9.4 1.2 12.6 6.5 0.4 0 0.4 0.4 36 0 36 305 81 1 82 0 -8.6 0 -8.4 -8.8 12/17/2004 09:20:00 9.5 1 12.2 6.8 9.3 1 12.2 6.8 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -8.6 0.1 -8.4 -8.8 12/17/2004 09:30:00 9.4 1.2 11.8 6.1 9.4 1.2 12.2 6.8 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -8.5 0 -8.2 -8.6 12/17/2004 09:40:00 9.2 1.1 12.2 6.8 9.2 1.1 12.6 6.8 0.4 0 0.4 0.4 36 0 36 305 83 0 82 0 -8.4 0 -8.2 -8.6 12/17/2004 09:50:00 9 0.9 11.5 6.8 8.8 0.9 11.1 6.5 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -8.4 0 -8.2 -8.6 12/17/2004 10:00:00 9.1 1.2 11.5 6.5 8.8 1.1 11.1 6.5 0.4 0 0.4 0.4 36 0 36 305 83 0 84 0 -8.4 0 -8.2 -8.6 12/17/2004 10:10:00 8 1 10.7 6.1 7.9 0.9 10.7 5.7 0.4 0 0.4 0.4 36 0 36 305 83 0 84 0 -8.4 0 -8.2 -8.6 12/17/2004 10:20:00 8.1 0.9 10.7 5.7 8 0.9 10.3 6.1 0.4 0 0.4 0.4 36 0 36 305 83 0 84 0 -8.3 0 -7.9 -8.4 12/17/2004 10:30:00 8.8 1 11.1 6.5 8.6 1 11.1 6.1 0.4 0 0.4 0.4 36 0 36 305 83 0 84 0 -8.3 0 -7.9 -8.4 12/17/2004 10:40:00 7.6 0.9 9.9 5.7 7.5 0.9 10.3 5.7 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -8.2 0 -7.9 -8.4 12/17/2004 10:50:00 7.7 1 9.9 5.3 7.7 1 9.9 5.7 0.4 0 0.7 0.4 36 0 36 305 83 0 84 0 -8.2 0 -7.9 -8.4 12/17/2004 11:00:00 8 1 11.1 5.7 8.1 0.9 10.7 6.1 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -8.2 0 -7.7 -8.2 12/17/2004 11:10:00 8.1 1 11.1 6.1 8 1 10.7 5.7 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -8 0.1 -7.7 -8.2 12/17/2004 11:20:00 8.8 0.9 11.1 6.5 8.7 0.9 11.1 6.8 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -8 0.1 -7.7 -8.2 12/17/2004 11:30:00 8.8 1.2 11.8 6.1 8.7 1.2 11.5 6.5 0.4 0 0.4 0.4 36 0 36 305 81 0 81 0 -8 0.1 -7.7 -8.2 12/17/2004 11:40:00 7.5 1 9.9 4.9 7.3 1 9.9 4.9 0.4 0 0.4 0.4 36 0 36 305 81 0 81 0 -8 0.1 -7.7 -8.2 12/17/2004 11:50:00 7.7 0.9 9.9 5.3 7.7 1 10.3 5.3 0.4 0 0.4 0.4 36 0 36 305 81 0 81 0 -8.1 0 -7.7 -8.2 12/17/2004 12:00:00 8.5 1.3 12.2 5.3 8.4 1.2 11.8 5.3 0.4 0 0.4 0.4 36 0 36 305 80 0 80 0 -8.2 0 -7.7 -8.2 12/17/2004 12:10:00 8.3 1.1 11.1 5.3 8.3 1.1 11.1 5.7 0.4 0 0.4 0.4 36 0 36 305 80 0 80 0 -8.2 0 -7.9 -8.4 12/17/2004 12:20:00 8.2 0.9 9.9 6.5 8.2 0.9 10.7 6.1 0.4 0 0.4 0.4 36 0 36 305 80 0 80 0 -8.2 0 -7.9 -8.4 12/17/2004 12:30:00 7.9 1.1 10.7 5.3 7.9 1 10.7 5.7 0.4 0 0.4 0.4 36 0 36 305 80 0 80 0 -8.3 0 -8.2 -8.4 12/17/2004 12:40:00 8.2 0.9 11.5 6.1 8.1 0.9 11.1 6.1 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -8.4 0 -8.2 -8.4 12/17/2004 12:50:00 9.2 1.3 11.8 6.5 9.3 1.3 11.8 6.5 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -8.5 0 -8.2 -8.6 12/17/2004 13:00:00 8.8 1.2 11.8 5.7 8.7 1.2 11.5 5.7 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -8.5 0 -8.2 -8.6 12/17/2004 13:10:00 9.8 1.2 12.2 6.8 9.7 1.2 12.2 6.5 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -8.5 0 -8.2 -8.6 12/17/2004 13:20:00 10.1 1 13 6.8 9.9 1 12.6 7.2 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -8.5 0 -8.2 -8.8 12/17/2004 13:30:00 10.1 1.2 13 7.2 10 1.2 13.3 6.8 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -8.6 0 -8.4 -8.8 12/17/2004 13:40:00 10.3 1.2 13 6.8 10.2 1.1 13 7.2 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -8.6 0.1 -8.4 -8.8 12/17/2004 13:50:00 10.5 1.1 13.3 7.6 10.2 1.1 13 8 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -8.6 0.1 -8.4 -8.8 12/17/2004 14:00:00 10.3 1.4 13.3 7.2 10.2 1.4 13.7 7.2 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -8.5 0 -8.2 -8.6 12/17/2004 14:10:00 9.2 0.9 11.5 6.5 9.1 0.9 11.5 6.1 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -8.4 0 -8.2 -8.6 12/17/2004 14:20:00 10 1.1 13.3 7.6 9.8 1 11.8 7.2 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -8.4 0 -8.2 -8.6 12/17/2004 14:30:00 9.3 1.5 13.3 6.1 9.3 1.5 13.7 6.1 0.4 0 0.4 0.4 36 0 36 305 78 0 79 0 -8.4 0 -8.2 -8.6 12/17/2004 14:40:00 9.9 1.3 12.6 6.8 9.9 1.2 12.6 7.6 0.4 0 0.4 0.4 36 0 36 305 78 0 78 0 -8.4 0 -8.2 -8.6 12/17/2004 14:50:00 9.7 1 12.6 7.2 9.6 1 12.6 7.2 0.4 0 0.4 0.4 36 0 36 305 78 0 78 0 -8.4 0.1 -8.2 -8.6 12/17/2004 15:00:00 10.4 1.1 13.3 7.2 10.2 1.1 13.3 7.2 0.4 0 0.4 0.4 36 0 36 305 78 0 78 0 -8.5 0 -8.2 -8.6 12/17/2004 15:10:00 10.5 1.3 13.3 7.2 10.5 1.3 13.7 7.2 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.5 0 -8.4 -8.8 12/17/2004 15:20:00 9.6 1.1 12.6 6.8 9.7 1.1 13 7.6 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.5 0 -8.2 -8.6 12/17/2004 15:30:00 9.4 1 11.8 6.8 9.4 1 11.5 7.2 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.5 0 -8.2 -8.6 12/17/2004 15:40:00 9.6 1.3 12.6 6.5 9.5 1.3 13 6.5 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.4 0 -8.2 -8.6 12/17/2004 15:50:00 9.4 1.2 12.2 6.5 9.3 1.2 12.2 6.5 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.4 0 -8.2 -8.6 12/17/2004 16:00:00 9.1 1.2 12.6 6.1 9.2 1.2 12.2 6.5 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.4 0 -8.2 -8.4 12/17/2004 16:10:00 9.3 1.3 12.2 6.1 9.3 1.2 12.6 6.5 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.3 0 -7.9 -8.4 12/17/2004 16:20:00 8.9 1.2 12.2 5.7 9 1.1 11.8 6.1 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.3 0 -7.9 -8.4 12/17/2004 16:30:00 8.9 1.1 12.2 6.1 8.7 1 12.6 6.5 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.2 0 -7.9 -8.4 12/17/2004 16:40:00 9.1 1 11.8 6.1 9 0.9 12.2 6.1 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.2 0 -7.9 -8.2 12/17/2004 16:50:00 8.4 1 10.7 6.1 8.5 1 10.7 6.1 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.2 0 -7.7 -8.2 12/17/2004 17:00:00 8.2 1 10.7 5.3 8.2 1 10.7 5.7 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.2 0 -7.7 -8.2 12/17/2004 17:10:00 7.9 1.1 10.7 5.3 8 1 10.7 5.3 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.2 0 -7.7 -8.2 12/17/2004 17:20:00 8.5 0.9 11.5 6.5 8.4 1 11.1 6.5 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8.1 0 -7.7 -8.2 12/17/2004 17:30:00 9 1 11.5 6.5 8.9 1 11.8 6.8 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8 0 -7.7 -8.2 12/17/2004 17:40:00 9 1.1 11.5 6.5 9 1.2 11.8 6.1 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -8 0 -7.7 -8.2 12/17/2004 17:50:00 8.7 0.9 11.1 6.5 8.6 0.8 10.7 6.8 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -7.9 0 -7.7 -8.2 12/17/2004 18:00:00 9.6 1 12.6 6.8 9.5 1.1 13 6.8 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -7.9 0 -7.7 -8.2 12/17/2004 18:10:00 9.9 1.1 12.2 6.8 9.9 1.1 12.6 6.8 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -7.9 0 -7.7 -7.9 12/17/2004 18:20:00 9.9 1 12.2 7.6 9.8 1 12.2 7.2 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -7.8 0 -7.7 -7.9 12/17/2004 18:30:00 9.7 1.2 12.6 6.8 9.7 1.1 13 6.8 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -7.7 0 -7.3 -7.9 12/17/2004 18:40:00 9.3 1.2 12.6 6.5 9.2 1.1 12.6 6.8 0.4 0 0.4 0.4 36 0 36 305 77 0 77 0 -7.6 0 -7.3 -7.7 12/17/2004 18:50:00 8.5 1.2 11.1 5.7 8.3 1.1 11.1 6.1 0.4 0 0.4 0.4 36 0 36 305 78 0 78 0 -7.5 0 -7.1 -7.7 12/17/2004 19:00:00 8.9 1.2 11.5 6.1 8.9 1.1 11.5 6.5 0.4 0 0.4 0.4 36 0 36 305 78 0 78 0 -7.3 0 -6.9 -7.5 12/17/2004 19:10:00 8.2 1.3 11.8 4.9 8.1 1.2 11.8 5.3 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -7.2 0 -7.1 -7.3 12/17/2004 19:20:00 8.5 1 11.5 5.7 8.3 1.1 11.5 5.7 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -7.2 0 -6.9 -7.3 12/17/2004 19:30:00 8 1.2 11.5 5.7 8 1.2 11.8 4.9 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -7.1 0 -6.9 -7.3 12/17/2004 19:40:00 6.6 1.3 10.3 4.2 6.7 1.3 10.3 4.2 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -7.1 0 -6.9 -7.3 12/17/2004 19:50:00 7 1.3 9.9 3.8 6.8 1.1 9.5 4.2 0.4 0 0.4 0.4 36 0 36 305 79 0 79 0 -7.1 0 -6.9 -7.3 12/17/2004 20:00:00 6.1 1.4 9.9 3 6.1 1.2 9.1 3.8 0.4 0 0.4 0.4 36 0 36 305 82 2 84 0 -7.1 0 -6.9 -7.1 12/17/2004 20:10:00 5.4 1.3 8.4 1.9 5.3 1.2 8.4 2.6 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -7 0 -6.7 -7.1 12/17/2004 20:20:00 5.5 0.9 8 3 5.3 0.9 7.6 3 0.4 0 0.4 0.4 36 0 36 305 83 0 84 0 -6.9 0 -6.7 -7.1 12/17/2004 20:30:00 5.8 1 8.8 3.8 5.8 1 8 3.8 0.4 0 0.4 0.4 36 0 36 305 83 0 84 0 -6.9 0 -6.7 -7.1 12/17/2004 20:40:00 7.3 1 11.1 4.9 7.1 1 10.7 4.6 0.4 0 0.4 0.4 36 0 36 305 83 0 84 0 -7 0 -6.9 -7.1 12/17/2004 20:50:00 7.9 1.1 10.7 5.3 7.7 1 10.7 5.3 0.4 0 0.4 0.4 36 0 38 305 83 0 83 0 -7 0 -6.9 -7.1 12/17/2004 21:00:00 7 0.8 8.8 4.9 6.8 0.8 9.5 4.6 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -7 0 -6.7 -7.1 12/17/2004 21:10:00 6.8 0.9 9.1 4.9 6.6 0.8 9.5 4.9 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -7 0 -6.7 -7.1 12/17/2004 21:20:00 7 0.8 8.8 4.9 7.2 0.8 9.1 4.9 0.4 0 0.4 0.4 36 0 36 305 83 0 84 0 -6.9 0 -6.7 -6.9 12/17/2004 21:30:00 6.3 1 9.1 3.4 6.4 0.9 8.8 4.2 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -6.9 0 -6.7 -6.9 12/17/2004 21:40:00 6.7 1 8.8 4.6 6.6 0.9 9.1 4.6 0.4 0 0.4 0.4 36 0 36 305 83 0 84 0 -6.9 0 -6.7 -7.1 12/17/2004 21:50:00 6.6 0.9 9.5 4.6 6.5 1 9.1 3.8 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -7 0 -6.9 -7.3 12/17/2004 22:00:00 6.8 0.7 8.8 4.9 6.8 0.8 8.8 4.6 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -7.1 0 -6.9 -7.3 12/17/2004 22:10:00 6.5 0.8 9.1 4.2 6.4 1 8.8 4.6 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -7.1 0 -6.9 -7.1 12/17/2004 22:20:00 5.8 0.7 8 4.2 5.7 0.8 8 3.8 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -6.9 0 -6.7 -7.1 12/17/2004 22:30:00 5.4 0.7 7.2 4.2 5.2 0.7 7.2 3 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -6.8 0 -6.7 -6.9 12/17/2004 22:40:00 5.3 0.7 7.6 3.8 5.1 0.7 7.2 3.4 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -6.6 0 -6.4 -6.9 12/17/2004 22:50:00 5.2 0.8 7.2 3.4 5 0.9 7.6 3 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -6.5 0 -6.2 -6.7 12/17/2004 23:00:00 4.5 0.7 6.5 2.6 4.3 0.8 6.5 2.6 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -6.4 0 -6.2 -6.7 12/17/2004 23:10:00 5.5 0.8 7.6 3.8 5.2 0.8 7.2 3.4 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -6.5 0 -6.2 -6.7 12/17/2004 23:20:00 5.8 0.8 8 3.8 5.5 0.9 8 3.8 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -6.5 0 -6.2 -6.7 12/17/2004 23:30:00 5.4 0.8 8.4 3.4 5.2 0.8 7.2 3 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -6.7 0 -6.7 -6.9 12/17/2004 23:40:00 5.4 1.2 8 2.3 5.1 1.1 8 2.6 0.4 0 0.4 0.4 36 0 36 305 83 0 82 0 -6.8 0 -6.7 -6.9 12/17/2004 23:50:00 5.1 0.9 7.2 2.6 4.7 0.8 6.8 2.6 0.4 0 0.4 0.4 36 0 36 305 83 0 82 0 -6.8 0 -6.7 -6.9 12/18/2004 00:00:00 4.9 1 7.2 2.6 4.8 0.9 7.6 2.6 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -6.9 0 -6.7 -7.1 12/18/2004 00:10:00 4.4 0.9 6.1 1.9 4.2 0.9 6.8 2.6 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -7 0 -6.9 -7.1 12/18/2004 00:20:00 4.5 0.9 6.8 2.3 4.4 1 6.5 2.3 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -7 0 -6.9 -7.1 12/18/2004 00:30:00 4.6 0.8 7.2 2.3 4.4 0.9 7.6 2.3 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -7.1 0 -6.9 -7.3 12/18/2004 00:40:00 4.8 0.8 7.2 2.6 4.7 0.8 7.6 3 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -7.1 0 -6.9 -7.3 12/18/2004 00:50:00 5 0.8 6.8 3 4.9 0.9 7.2 2.6 0.4 0 0.4 0.4 36 0 36 305 83 0 83 0 -7.1 0 -7.1 -7.3 12/18/2004 01:00:00 4.4 1 6.8 1.9 4.2 0.9 7.2 2.3 0.4 0 0.4 0.4 36 0 36 305 83 0 82 0 -7.1 0 -6.9 -7.3 12/18/2004 01:10:00 3.6 0.9 6.5 1.1 3.4 0.8 5.3 1.1 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -7.1 0 -7.1 -7.3 12/18/2004 01:20:00 4.3 1 8 2.3 4 1 7.2 1.9 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -7.2 0 -7.1 -7.3 12/18/2004 01:30:00 4.1 1 7.2 1.9 3.8 1 6.8 1.1 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -7.2 0 -7.1 -7.3 12/18/2004 01:40:00 4.4 1 7.2 1.9 4.4 1 6.8 2.6 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -7.2 0 -7.1 -7.3 12/18/2004 01:50:00 4.6 1 7.6 2.3 4.7 1.2 8.4 1.5 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -7.2 0 -7.1 -7.3 12/18/2004 02:00:00 4.7 1 7.6 2.3 4.4 1 6.8 1.9 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -7.2 0 -7.1 -7.3 12/18/2004 02:10:00 3.8 0.8 6.5 1.9 3.7 1 6.8 1.9 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -7.2 0 -7.1 -7.3 12/18/2004 02:20:00 3.6 0.9 6.5 1.5 3.4 0.9 6.5 0.7 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -7.1 0 -7.1 -7.3 12/18/2004 02:30:00 3.2 1.5 6.1 0.4 3.4 0.9 6.5 1.5 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -7.1 0 -6.9 -7.3 12/18/2004 02:40:00 3.1 0.9 5.3 0.7 2.9 0.8 5.3 1.1 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -7 0 -6.9 -7.1 12/18/2004 02:50:00 3.5 1.1 6.1 1.5 3.4 1.1 6.1 1.1 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -6.9 0 -6.7 -7.1 12/18/2004 03:00:00 2.6 1.1 6.1 0.4 1.5 1.3 4.9 0.4 0.4 0 0.4 0.4 36 0 36 305 82 0 82 0 -7 0 -6.9 -7.1 12/18/2004 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -6.9 0 -6.7 -7.1 12/18/2004 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -6.8 0 -6.7 -6.9 12/18/2004 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -6.9 0 -6.7 -6.9 12/18/2004 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -6.9 0 -6.7 -6.9 12/18/2004 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -6.9 0 -6.7 -7.1 12/18/2004 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -6.9 0 -6.7 -7.1 12/18/2004 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -6.9 0 -6.7 -6.9 12/18/2004 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -6.9 0 -6.7 -7.1 12/18/2004 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -7 0 -6.7 -7.1 12/18/2004 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -7 0 -6.9 -7.1 12/18/2004 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -6.9 0 -6.7 -7.1 12/18/2004 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 82 0 0 0 -6.9 0 -6.7 -6.9 12/18/2004 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.9 0 -6.7 -6.9 12/18/2004 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.8 0 -6.7 -6.9 12/18/2004 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.8 0 -6.7 -6.9 12/18/2004 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.8 0 -6.7 -6.9 12/18/2004 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.8 0 -6.7 -6.9 12/18/2004 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.7 0 -6.7 -6.9 12/18/2004 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.7 0 -6.7 -6.9 12/18/2004 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.8 0 -6.7 -6.9 12/18/2004 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.9 0 -6.7 -6.9 12/18/2004 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.9 0 -6.7 -7.1 12/18/2004 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -7 0 -6.9 -7.1 12/18/2004 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -7 0 -6.9 -7.1 12/18/2004 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.9 0 -6.7 -7.1 12/18/2004 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.8 0 -6.7 -6.9 12/18/2004 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -6.9 0 -6.7 -7.1 12/18/2004 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 81 0 0 0 -7.1 0 -6.9 -7.1 12/18/2004 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 80 0 0 0 -7.1 0 -6.9 -7.3 12/18/2004 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 80 0 0 0 -7.1 0 -6.9 -7.3 12/18/2004 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 80 0 0 0 -7.2 0 -7.1 -7.3 12/18/2004 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 80 0 0 0 -7.3 0 -7.1 -7.5 12/18/2004 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 80 0 0 0 -7.5 0.1 -7.3 -7.7 12/18/2004 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -7.7 0 -7.5 -7.7 12/18/2004 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -7.7 0 -7.3 -7.9 12/18/2004 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -7.9 0 -7.7 -8.2 12/18/2004 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -8.1 0 -7.9 -8.2 12/18/2004 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -8.3 0 -7.9 -8.4 12/18/2004 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 78 0 0 0 -8.5 0 -8.4 -8.6 12/18/2004 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -8.6 0 -8.4 -8.8 12/18/2004 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -8.8 0 -8.6 -9 12/18/2004 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -8.9 0 -8.8 -9.2 12/18/2004 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 77 0 0 0 -9.1 0 -9 -9.2 12/18/2004 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 77 0 0 0 -9.2 0 -9 -9.2 12/18/2004 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 77 0 0 0 -9.3 0 -9.2 -9.2 12/18/2004 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 77 0 0 0 -9.3 0 -9 -9.2 12/18/2004 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 77 0 0 0 -9.3 0 -9 -9.2 12/18/2004 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 77 0 0 0 -9.3 0 -9 -9.2 12/18/2004 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.2 0 -9 -9.2 12/18/2004 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.3 0 -9 -9.2 12/18/2004 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.2 0 -9 -9.2 12/18/2004 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.3 0 -9.2 -9.4 12/18/2004 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.3 0 -9 -9.4 12/18/2004 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.3 0 -9 -9.2 12/18/2004 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.3 0 -9 -9.4 12/18/2004 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.1 0 -8.8 -9.2 12/18/2004 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.2 0 -9 -9.2 12/18/2004 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.1 0 -9 -9.2 12/18/2004 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -9 0 -8.8 -9.2 12/18/2004 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -9.1 0 -9 -9.2 12/18/2004 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -9 0 -8.8 -9.2 12/18/2004 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -8.7 0 -8.4 -8.8 12/18/2004 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -8.5 0 -8.4 -8.8 12/18/2004 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -8.4 0 -8.2 -8.6 12/18/2004 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -8.3 0 -8.2 -8.4 12/18/2004 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -8.3 0 -8.2 -8.4 12/18/2004 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 80 0 0 0 -8.3 0 -8.2 -8.4 12/18/2004 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 80 0 0 0 -8.3 0 -8.2 -8.4 12/18/2004 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 80 0 0 0 -8.2 0 -8.2 -8.4 12/18/2004 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 80 0 0 0 -8.3 0 -8.2 -8.4 12/18/2004 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -8.6 0.1 -8.2 -8.8 12/18/2004 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -8.7 0 -8.4 -9 12/18/2004 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -8.9 0 -8.6 -9.2 12/18/2004 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 79 0 0 0 -9.1 0 -8.8 -9.2 12/18/2004 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.1 0 -9 -9.2 12/18/2004 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.2 0 -9 -9.2 12/18/2004 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.3 0 -9.2 -9.4 12/18/2004 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.3 0 -9 -9.4 12/18/2004 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.4 0 -9.2 -9.4 12/18/2004 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.4 0 -9.2 -9.6 12/18/2004 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.4 0 -9.2 -9.6 12/18/2004 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.4 0 -9.2 -9.6 12/18/2004 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.4 0 -9.2 -9.6 12/18/2004 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.4 0 -9.2 -9.6 12/18/2004 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.4 0 -9.2 -9.6 12/18/2004 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.4 0 -9.2 -9.6 12/18/2004 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.4 0 -9.2 -9.6 12/18/2004 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.5 0 -9.2 -9.6 12/18/2004 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.7 0.1 -9.4 -9.8 12/18/2004 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.8 0 -9.8 -10 12/18/2004 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.9 0 -9.8 -10 12/18/2004 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -9.9 0 -9.8 -10 12/18/2004 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 305 305 78 0 0 0 -10 0 -9.8 -10.2 12/18/2004 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 78 0 0 0 -10.2 0 -10 -10.4 12/18/2004 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 77 0 0 0 -10.3 0 -10 -10.4 12/18/2004 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 77 0 0 0 -10.4 0 -10.2 -10.4 12/18/2004 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 78 0 0 0 -10.5 0 -10.4 -10.7 12/18/2004 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 78 0 0 0 -10.5 0 -10.4 -10.9 12/18/2004 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -10.5 0 -10.4 -10.9 12/18/2004 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -10.6 0 -10.4 -10.9 12/18/2004 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.6 0 -10.4 -10.9 12/18/2004 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -10.7 0 -10.4 -10.9 12/18/2004 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.7 0 -10.4 -10.9 12/18/2004 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -10.7 0 -10.4 -10.9 12/18/2004 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -10.7 0 -10.4 -10.9 12/18/2004 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -10.6 0 -10.4 -10.9 12/18/2004 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 1 305 305 81 0 0 0 -10.5 0 -10.4 -10.9 12/18/2004 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -10.5 0 -10.2 -10.7 12/18/2004 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -10.4 0 -10.2 -10.7 12/18/2004 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.4 0 -10.2 -10.4 12/18/2004 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.4 0 -10 -10.4 12/18/2004 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.4 0 -10.4 -10.4 12/18/2004 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -10.4 0 -10.4 -10.4 12/18/2004 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -10.4 0 -10.2 -10.7 12/18/2004 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.5 0 -10.4 -10.7 12/18/2004 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.5 0 -10.4 -10.7 12/18/2004 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.5 0 -10.4 -10.9 12/18/2004 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.6 0 -10.4 -10.9 12/18/2004 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.7 0 -10.4 -10.9 12/18/2004 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.7 0 -10.4 -10.9 12/18/2004 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -10.8 0 -10.4 -10.9 12/18/2004 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.9 0 -10.9 -10.9 12/18/2004 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -10.9 0 -10.9 -11.1 12/18/2004 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -11 0 -10.9 -11.3 12/18/2004 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -11.1 0 -10.9 -11.3 12/19/2004 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -11.2 0 -11.1 -11.3 12/19/2004 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 79 0 0 0 -11.2 0 -11.1 -11.5 12/19/2004 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -11.3 0 -11.3 -11.5 12/19/2004 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 79 0 0 0 -11.4 0 -11.3 -11.5 12/19/2004 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -11.4 0 -11.3 -11.5 12/19/2004 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 81 0 0 0 -11.5 0 -11.3 -11.7 12/19/2004 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -11.5 0 -11.5 -11.7 12/19/2004 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 80 0 0 0 -11.5 0 -11.5 -11.7 12/19/2004 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 80 0 0 0 -11.5 0 -11.5 -11.7 12/19/2004 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 80 0 0 0 -11.6 0 -11.5 -11.7 12/19/2004 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -11.6 0 -11.5 -11.9 12/19/2004 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 80 0 0 0 -11.8 0 -11.7 -12.1 12/19/2004 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -11.8 0 -11.7 -12.1 12/19/2004 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -11.8 0 -11.7 -11.9 12/19/2004 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -11.8 0 -11.7 -11.9 12/19/2004 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.8 0 -11.7 -12.1 12/19/2004 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.9 0 -11.7 -12.1 12/19/2004 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12 0 -11.7 -12.1 12/19/2004 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12 0 -11.9 -12.1 12/19/2004 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12 0 -11.7 -12.1 12/19/2004 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -12 0 -11.9 -12.1 12/19/2004 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -12.1 0 -12.1 -12.3 12/19/2004 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -12.2 0 -12.1 -12.5 12/19/2004 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -12.3 0 -12.1 -12.5 12/19/2004 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.3 0 -12.1 -12.5 12/19/2004 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.4 0 -12.3 -12.5 12/19/2004 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.4 0 -12.3 -12.5 12/19/2004 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 80 0 0 0 -12.4 0 -12.1 -12.5 12/19/2004 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 80 0 0 0 -12.4 0.1 -12.3 -12.5 12/19/2004 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.4 0 -12.3 -12.5 12/19/2004 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.5 0 -12.3 -12.5 12/19/2004 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -12.5 0 -12.3 -12.5 12/19/2004 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.5 0 -12.3 -12.5 12/19/2004 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.6 0 -12.5 -12.5 12/19/2004 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.5 0 -12.5 -12.7 12/19/2004 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.9 12/19/2004 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -12.8 0 -12.5 -12.9 12/19/2004 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.8 0 -12.5 -12.9 12/19/2004 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.8 0 -12.7 -12.9 12/19/2004 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.8 0 -12.7 -12.9 12/19/2004 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.8 0 -12.7 -12.9 12/19/2004 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.8 0 -12.5 -12.9 12/19/2004 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.8 0 -12.7 -12.9 12/19/2004 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.8 0 -12.5 -12.9 12/19/2004 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.9 0 -12.7 -12.9 12/19/2004 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.8 0 -12.7 -12.9 12/19/2004 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.9 12/19/2004 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 81 0 0 0 -12.6 0 -12.5 -12.9 12/19/2004 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 81 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 81 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 81 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12.6 0 -12.5 -12.9 12/19/2004 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.9 12/19/2004 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.9 12/19/2004 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -12.6 0 -12.3 -12.7 12/19/2004 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.6 0 -12.3 -12.7 12/19/2004 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.5 0 -12.3 -12.5 12/19/2004 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.5 0 -12.3 -12.7 12/19/2004 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.5 0 -12.3 -12.5 12/19/2004 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.5 0 -12.1 -12.5 12/19/2004 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.4 0.1 -12.1 -12.5 12/19/2004 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.4 0 -12.3 -12.5 12/19/2004 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.3 0 -12.1 -12.5 12/19/2004 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -12.2 0 -12.1 -12.5 12/19/2004 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -12.1 0 -12.1 -12.3 12/19/2004 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 83 0 0 0 -12 0 -12.1 -12.3 12/19/2004 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -12 0 -11.9 -12.1 12/19/2004 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -12 0 -11.7 -12.1 12/19/2004 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -11.9 0 -11.7 -12.1 12/19/2004 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -11.9 0 -11.7 -12.1 12/19/2004 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.9 0 -11.7 -12.1 12/19/2004 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.9 0 -11.7 -12.1 12/19/2004 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.8 0 -11.7 -12.1 12/19/2004 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.7 0 -11.7 -11.9 12/19/2004 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -11.7 0 -11.5 -11.9 12/19/2004 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -11.8 0.1 -11.5 -12.1 12/19/2004 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 82 0 0 0 -11.8 0 -11.5 -12.1 12/19/2004 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.8 0 -11.5 -11.9 12/19/2004 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.8 0 -11.5 -12.1 12/19/2004 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.9 0 -11.7 -12.1 12/19/2004 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.8 0 -11.7 -12.1 12/19/2004 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.9 0 -11.7 -12.1 12/19/2004 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -11.9 0 -11.7 -12.1 12/19/2004 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.9 0.1 -11.7 -12.1 12/19/2004 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.9 0 -11.7 -12.1 12/19/2004 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 81 0 0 0 -11.9 0 -11.7 -12.1 12/19/2004 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12 0 -11.7 -12.1 12/19/2004 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12 0 -11.7 -12.1 12/19/2004 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12 0 -11.9 -12.1 12/19/2004 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 80 0 0 0 -12 0 -11.9 -12.1 12/19/2004 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -12 0 -11.9 -12.1 12/19/2004 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -12.1 0 -12.1 -12.3 12/19/2004 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -12.2 0 -12.1 -12.5 12/19/2004 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 79 0 0 0 -12.2 0 -12.1 -12.5 12/19/2004 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 78 0 0 0 -12.3 0 -12.1 -12.5 12/19/2004 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 78 0 0 0 -12.4 0 -12.3 -12.5 12/19/2004 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 79 0 0 0 -12.3 0 -12.3 -12.5 12/19/2004 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 79 0 0 0 -12.4 0 -12.3 -12.5 12/19/2004 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 79 0 0 0 -12.5 0 -12.3 -12.5 12/19/2004 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 79 0 0 0 -12.4 0 -12.3 -12.5 12/19/2004 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 79 0 0 0 -12.5 0 -12.3 -12.7 12/19/2004 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 79 0 0 0 -12.6 0 -12.5 -12.7 12/19/2004 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 78 0 0 0 -12.6 0 -12.5 -12.9 12/19/2004 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 78 0 0 0 -12.7 0 -12.5 -12.9 12/19/2004 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 78 0 0 0 -12.6 0 -12.5 -12.9 12/19/2004 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 78 0 0 0 -12.7 0.1 -12.5 -13.3 12/19/2004 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 77 0 0 0 -14.3 0.4 -13.3 -14.8 12/19/2004 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 76 0 0 0 -15 0.1 -14.6 -15 12/19/2004 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 76 0 0 0 -15.4 0.2 -15 -15.6 12/19/2004 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 76 0 0 0 -15.6 0 -15.4 -15.8 12/19/2004 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 76 0 0 0 -15.7 0 -15.6 -15.8 12/19/2004 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 76 0 0 0 -15.8 0 -15.6 -16 12/19/2004 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -15.9 0 -15.8 -16.2 12/19/2004 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16 0 -15.8 -16.2 12/19/2004 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.1 0 -16 -16.2 12/19/2004 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16 0 -16 -16.2 12/19/2004 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -15.9 0 -15.8 -16 12/19/2004 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16 0 -15.8 -16.2 12/19/2004 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.1 0 -16 -16.2 12/19/2004 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.1 0 -16 -16.2 12/19/2004 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.2 0 -16 -16.4 12/19/2004 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.1 0 -16 -16.2 12/19/2004 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16 0 -15.6 -16.2 12/20/2004 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.1 0 -16 -16.2 12/20/2004 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.1 0 -16 -16.2 12/20/2004 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.1 0 -16 -16.2 12/20/2004 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 75 0 0 0 -16.2 0 -16 -16.4 12/20/2004 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.2 0 -16 -16.4 12/20/2004 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 75 0 0 0 -16.3 0 -16 -16.4 12/20/2004 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.3 0 -16.2 -16.4 12/20/2004 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.2 0 -16 -16.4 12/20/2004 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.2 0 -16 -16.4 12/20/2004 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 75 0 0 0 -16.1 0 -16 -16.4 12/20/2004 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 75 0 0 0 -16.2 0 -16 -16.4 12/20/2004 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 75 0 0 0 -16.3 0 -16 -16.4 12/20/2004 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.3 0 -16 -16.4 12/20/2004 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.3 0 -16.2 -16.4 12/20/2004 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.4 0 -16.2 -16.4 12/20/2004 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -16.3 0 -16.2 -16.6 12/20/2004 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.3 0 -16.2 -16.4 12/20/2004 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.3 0 -16.2 -16.4 12/20/2004 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.3 0 -16.2 -16.4 12/20/2004 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 75 0 0 0 -16.3 0 -15.8 -16.4 12/20/2004 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 75 0 0 0 -16.3 0 -15.8 -16.4 12/20/2004 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 74 0 0 0 -16.3 0 -15.8 -16.4 12/20/2004 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 74 0 0 0 -16.3 0 -15.8 -16.4 12/20/2004 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 75 0 0 0 -16.3 0 -15.8 -16.4 12/20/2004 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.2 0 -16 -16.4 12/20/2004 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.2 0 -16 -16.4 12/20/2004 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -16.2 0 -16 -16.4 12/20/2004 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 75 0 0 0 -16.3 0 -16 -16.4 12/20/2004 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -16.4 0 -16.2 -16.6 12/20/2004 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -16.6 0 -16.4 -16.9 12/20/2004 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 74 0 0 0 -16.6 0 -16 -16.7 12/20/2004 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 74 0 0 0 -16.6 0 -16.2 -16.6 12/20/2004 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 73 0 0 0 -16.8 0.1 -16.4 -16.9 12/20/2004 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -17 0 -16.9 -17.1 12/20/2004 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -17.2 0.1 -16.9 -17.5 12/20/2004 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -17.4 0 -17.1 -17.5 12/20/2004 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -17.3 0 -17.1 -17.5 12/20/2004 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -17.5 0.1 -17.3 -17.9 12/20/2004 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -17.8 0 -17.5 -17.9 12/20/2004 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -17.8 0 -17.5 -17.9 12/20/2004 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -17.9 0 -17.7 -18.1 12/20/2004 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -18.1 0.1 -17.9 -18.4 12/20/2004 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -18.3 0 -18.1 -18.4 12/20/2004 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -18.4 0.1 -18.2 -18.4 12/20/2004 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -18.5 0 -18.4 -18.6 12/20/2004 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -18.6 0 -18.4 -18.8 12/20/2004 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 69 0 0 0 -18.6 0 -18.2 -18.8 12/20/2004 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 69 0 0 0 -18.6 0 -18.4 -18.8 12/20/2004 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -18.6 0 -18.4 -18.6 12/20/2004 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -18.6 0 -18.4 -18.6 12/20/2004 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -18.6 0 -18.4 -18.6 12/20/2004 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -18.4 0.1 -18.1 -18.4 12/20/2004 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -18.4 0 -18.1 -18.4 12/20/2004 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -18.3 0 -18.1 -18.4 12/20/2004 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 72 0 0 0 -18.2 0 -17.9 -18.4 12/20/2004 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 72 0 0 0 -18.2 0 -18.1 -18.2 12/20/2004 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 72 0 0 0 -18.1 0 -18.1 -18.2 12/20/2004 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 73 0 0 0 -18.1 0 -17.9 -18.2 12/20/2004 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 73 0 0 0 -18.2 0 -17.9 -18.4 12/20/2004 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 73 0 0 0 -18.2 0 -17.9 -18.4 12/20/2004 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -18 0 -17.7 -18.2 12/20/2004 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -17.8 0 -17.5 -18.1 12/20/2004 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -17.6 0 -17.5 -17.7 12/20/2004 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -17.7 0 -17.5 -17.9 12/20/2004 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -17.8 0.1 -17.5 -18.1 12/20/2004 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -17.9 0 -17.7 -18.1 12/20/2004 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -17.8 0 -17.5 -18.1 12/20/2004 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -17.6 0 -17.5 -17.7 12/20/2004 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -17.5 0 -17.3 -17.7 12/20/2004 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -17.5 0 -17.3 -17.5 12/20/2004 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -17.4 0 -17.3 -17.5 12/20/2004 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -17.5 0 -17.3 -17.5 12/20/2004 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -17.5 0.1 -17.1 -17.7 12/20/2004 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -17.4 0 -17.3 -17.5 12/20/2004 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 75 0 0 0 -17.5 0 -16.9 -17.5 12/20/2004 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 75 0 0 0 -17.5 0 -16.9 -17.5 12/20/2004 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 75 0 0 0 -17.5 0 -16.9 -17.5 12/20/2004 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 75 0 0 0 -17.3 0.1 -16.9 -17.5 12/20/2004 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 75 0 0 0 -17 0 -16.9 -17.1 12/20/2004 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 76 0 0 0 -17 0 -16.9 -17.1 12/20/2004 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 76 0 0 0 -17.3 0.1 -16.9 -17.5 12/20/2004 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 76 0 0 0 -17.5 0.1 -16.9 -17.7 12/20/2004 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 75 0 0 0 -17.7 0 -17.1 -17.9 12/20/2004 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 75 0 0 0 -17.9 0.1 -17.5 -18.1 12/20/2004 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 74 0 0 0 -18 0 -17.5 -18.1 12/20/2004 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 74 0 0 0 -17.9 0 -17.5 -18.1 12/20/2004 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 74 0 0 0 -18 0 -17.9 -18.1 12/20/2004 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 74 0 0 0 -18 0 -17.5 -18.1 12/20/2004 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -18 0 -17.7 -18.1 12/20/2004 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -17.7 0 -17.5 -18.1 12/20/2004 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -17.9 0 -17.7 -18.1 12/20/2004 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -18 0 -17.9 -18.1 12/20/2004 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -18.1 0 -18.1 -18.2 12/20/2004 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -18.2 0 -18.1 -18.4 12/20/2004 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -18.3 0 -18.1 -18.4 12/20/2004 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -18.5 0 -18.2 -18.6 12/20/2004 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -18.5 0 -18.2 -18.4 12/20/2004 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -18.5 0 -18.4 -18.6 12/20/2004 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -18.4 0.1 -18.2 -18.4 12/20/2004 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -18.5 0 -18.2 -18.6 12/20/2004 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -18.6 0 -18.4 -18.8 12/20/2004 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 72 0 0 0 -18.6 0 -18.1 -18.8 12/20/2004 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 72 0 0 0 -18.8 0 -18.4 -19 12/20/2004 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 71 0 0 0 -18.9 0 -18.4 -19 12/20/2004 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 71 0 0 0 -19.1 0 -19 -19 12/20/2004 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 71 0 0 0 -19.1 0 -18.6 -19.2 12/20/2004 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 70 0 0 0 -19.1 0 -18.8 -19.2 12/20/2004 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 70 0 0 0 -19.1 0 -18.8 -19.2 12/20/2004 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 70 0 0 0 -19.1 0 -18.8 -19.2 12/20/2004 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 70 0 0 0 -19.2 0 -19 -19.3 12/20/2004 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -19.3 0 -19 -19.5 12/20/2004 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 69 0 0 0 -19.4 0.1 -19.2 -19.5 12/20/2004 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 68 0 0 0 -19.6 0 -19.3 -19.7 12/20/2004 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 68 0 0 0 -19.7 0 -19.5 -19.9 12/20/2004 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 68 0 0 0 -19.7 0 -19.5 -19.9 12/20/2004 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -19.8 0 -19.5 -20.1 12/20/2004 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -19.9 0 -19.7 -20.1 12/20/2004 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -20 0 -19.9 -20.1 12/20/2004 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -20.2 0 -20.1 -20.2 12/20/2004 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -20.2 0 -20.1 -20.2 12/20/2004 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -20.2 0 -19.9 -20.4 12/20/2004 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -20.2 0 -19.9 -20.6 12/20/2004 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -20.3 0 -19.9 -20.6 12/20/2004 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.3 0.1 -19.9 -20.8 12/20/2004 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.8 0 -20.4 -21 12/20/2004 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.9 0 -20.4 -21.1 12/20/2004 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21 0.3 -20.2 -21.5 12/20/2004 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.8 0.2 -20.1 -21.3 12/20/2004 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.7 0 -20.1 -20.8 12/20/2004 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.7 0 -20.2 -20.8 12/20/2004 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.8 0 -20.6 -21 12/20/2004 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 63 0 0 0 -20.9 0 -20.4 -21 12/20/2004 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.9 0 -20.8 -21 12/20/2004 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21 0 -20.8 -21.3 12/20/2004 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21 0 -20.8 -21.1 12/20/2004 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.1 0.2 -20.8 -21.5 12/20/2004 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.4 0.1 -21 -21.7 12/20/2004 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.9 0.1 -20.4 -21.1 12/20/2004 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.7 0 -20.6 -21 12/20/2004 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.5 0.1 -20.2 -20.8 12/20/2004 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.4 0 -20.2 -20.6 12/20/2004 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.6 0 -20.1 -20.8 12/20/2004 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.4 0.1 -19.7 -20.8 12/20/2004 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.4 0.1 -19.9 -20.8 12/21/2004 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -20.2 0.1 -19.7 -20.4 12/21/2004 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -20.2 0.1 -19.5 -20.4 12/21/2004 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -20 0 -19.5 -20.1 12/21/2004 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -20 0.1 -19.5 -20.1 12/21/2004 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -20.1 0 -19.5 -20.2 12/21/2004 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -20.1 0 -19.5 -20.2 12/21/2004 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -20.1 0.1 -19.5 -20.1 12/21/2004 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -20.1 0 -19.5 -20.1 12/21/2004 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -20.1 0 -19.5 -20.1 12/21/2004 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.1 0.1 -19.5 -20.2 12/21/2004 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.2 0 -19.5 -20.2 12/21/2004 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.1 0.1 -19.5 -20.1 12/21/2004 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.2 0.1 -19.5 -20.6 12/21/2004 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.4 0.1 -19.9 -20.6 12/21/2004 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21 0.3 -20.1 -21.3 12/21/2004 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.5 0.1 -21 -21.8 12/21/2004 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.3 0.1 -20.8 -21.7 12/21/2004 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -20.6 0.2 -20.1 -21.3 12/21/2004 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.5 0.1 -19.9 -20.8 12/21/2004 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.7 0.1 -20.1 -21 12/21/2004 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21 0.1 -20.6 -21.3 12/21/2004 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.6 0.2 -20.8 -22 12/21/2004 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -22.3 0.1 -21.5 -22.5 12/21/2004 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -22.1 0.3 -21.3 -22.5 12/21/2004 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -21.6 0.2 -21 -21.8 12/21/2004 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.7 0.1 -21.3 -21.8 12/21/2004 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.3 0.1 -20.8 -21.8 12/21/2004 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.7 0.1 -21.3 -21.8 12/21/2004 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.5 0.2 -21 -21.8 12/21/2004 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.8 0.2 -21.3 -22.2 12/21/2004 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -22 0.1 -21.3 -22.2 12/21/2004 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.7 0.2 -21.3 -22 12/21/2004 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.8 0.1 -21.3 -22 12/21/2004 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.7 0.1 -21.3 -22 12/21/2004 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -22.2 0.2 -21.5 -22.5 12/21/2004 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -22 0.3 -21 -22.4 12/21/2004 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -21.4 0.2 -20.8 -21.8 12/21/2004 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -22.3 0.2 -21.7 -22.5 12/21/2004 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -22 0.2 -21.3 -22.4 12/21/2004 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -22.2 0.2 -21.5 -22.5 12/21/2004 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -21.8 0.2 -21.3 -22.4 12/21/2004 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -21.6 0.2 -21 -21.8 12/21/2004 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.1 0.2 -20.4 -21.5 12/21/2004 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.1 0.2 -20.2 -21.3 12/21/2004 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21 0.2 -20.2 -21.3 12/21/2004 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.2 0.1 -20.6 -21.3 12/21/2004 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -20.6 0.4 -19.5 -21.3 12/21/2004 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.2 0.2 -19.5 -20.6 12/21/2004 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.4 0.1 -19.9 -20.8 12/21/2004 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.2 0.1 -19.5 -20.6 12/21/2004 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.2 0.1 -19.9 -20.6 12/21/2004 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.3 0.2 -19.5 -20.6 12/21/2004 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.1 0.3 -19.5 -20.6 12/21/2004 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.1 0.2 -20.1 -21.3 12/21/2004 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.3 0.1 -20.8 -21.7 12/21/2004 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.6 0.4 -19.9 -21.3 12/21/2004 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.6 0.2 -19.9 -21 12/21/2004 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.7 0.2 -20.1 -21 12/21/2004 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.7 0.2 -20.1 -21.1 12/21/2004 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.3 0.2 -19.7 -20.8 12/21/2004 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.4 0.2 -19.5 -20.8 12/21/2004 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.1 0.1 -19.5 -20.2 12/21/2004 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.6 0.1 -20.1 -21 12/21/2004 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.3 0.2 -19.5 -20.8 12/21/2004 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.1 0.1 -19.5 -20.2 12/21/2004 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -19.9 0.2 -19.2 -20.1 12/21/2004 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.2 0.1 -19.5 -20.4 12/21/2004 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.5 0.1 -19.9 -20.8 12/21/2004 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.4 0.1 -19.7 -20.6 12/21/2004 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -20.9 0.3 -20.1 -21.3 12/21/2004 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21 0.3 -20.1 -21.3 12/21/2004 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -20.2 0.1 -19.5 -20.6 12/21/2004 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -20.8 0.2 -20.1 -21.3 12/21/2004 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -20.8 0.2 -20.1 -21.3 12/21/2004 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -21.3 0.3 -20.6 -21.8 12/21/2004 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -21.8 0.1 -21.3 -22 12/21/2004 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -21.8 0.1 -21.3 -22 12/21/2004 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -21.7 0.2 -21.3 -22 12/21/2004 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -22 0.1 -21.3 -22.4 12/21/2004 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 59 0 0 0 -22.1 0.1 -21.5 -22.4 12/21/2004 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 59 0 0 0 -22.3 0 -21.8 -22.5 12/21/2004 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 59 0 0 0 -22.3 0.1 -21.8 -22.4 12/21/2004 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -22 0.1 -21.3 -22.4 12/21/2004 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -21.5 0.2 -21 -21.8 12/21/2004 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 1 0 0 -20.9 0.4 -19.7 -21.5 12/21/2004 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21 0.4 -19.9 -21.3 12/21/2004 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -21 0.2 -20.2 -21.3 12/21/2004 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -20.3 0.2 -19.7 -20.8 12/21/2004 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -20.2 0 -19.5 -20.2 12/21/2004 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -20.6 0.3 -20.1 -21.1 12/21/2004 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -21.1 0.1 -20.8 -21.3 12/21/2004 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -21.5 0.1 -21.3 -21.8 12/21/2004 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -21.2 0.1 -20.8 -21.5 12/21/2004 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -20.7 0 -20.6 -21 12/21/2004 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -21.2 0.2 -20.8 -21.5 12/21/2004 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.3 0.2 -20.8 -21.7 12/21/2004 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -20.8 0.2 -20.1 -21 12/21/2004 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.1 0.1 -20.4 -21.3 12/21/2004 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.4 0.1 -20.8 -21.7 12/21/2004 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.3 0.1 -20.8 -21.7 12/21/2004 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -20.8 0.2 -20.1 -21.3 12/21/2004 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -20.9 0.3 -20.1 -21.3 12/21/2004 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -20.9 0.3 -20.1 -21.7 12/21/2004 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -21.7 0.1 -21.3 -21.8 12/21/2004 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 59 0 0 0 -21.7 0.2 -21.1 -21.8 12/21/2004 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 58 0 0 0 -21.7 0.2 -21 -22 12/21/2004 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 58 0 0 0 -21.9 0.1 -21.5 -22.2 12/21/2004 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 57 0 0 0 -21.9 0.1 -21.5 -22 12/21/2004 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 58 0 0 0 -21.5 0.2 -21 -21.8 12/21/2004 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 58 0 0 0 -21.7 0.1 -21 -21.8 12/21/2004 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 58 0 0 0 -21.3 0 -20.8 -21.3 12/21/2004 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 58 0 0 0 -20.8 0.2 -20.1 -21.3 12/21/2004 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 58 0 0 0 -21.5 0.1 -21 -21.7 12/21/2004 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 59 0 0 0 -21.3 0 -20.8 -21.3 12/21/2004 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 59 0 0 0 -21 0.2 -20.2 -21.3 12/21/2004 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 58 0 0 0 -20 0.3 -19 -20.8 12/21/2004 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 1 0 0 -19.2 0.1 -18.6 -19.5 12/21/2004 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -19.5 0.2 -18.6 -19.7 12/21/2004 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -19.7 0.1 -19 -19.9 12/21/2004 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -19.5 0.1 -18.8 -19.7 12/21/2004 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -19.3 0 -19 -19.5 12/21/2004 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -19.3 0.1 -18.8 -19.5 12/21/2004 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -19.6 0.5 -18.6 -20.6 12/21/2004 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -20.7 0.1 -20.1 -21 12/21/2004 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -21 0.1 -20.8 -21.3 12/21/2004 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -21.5 0.1 -21.1 -21.8 12/21/2004 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.5 0.2 -21.1 -21.8 12/21/2004 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.7 0.2 -20.8 -21.8 12/21/2004 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21 0.1 -20.4 -21.3 12/21/2004 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -21.2 0.1 -20.4 -21.5 12/21/2004 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -21.7 0.1 -21.1 -21.8 12/21/2004 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 1 0 0 -21.8 0 -21.3 -21.8 12/21/2004 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.5 0.2 -20.8 -21.8 12/21/2004 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.6 0.1 -21 -21.8 12/21/2004 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.8 0.1 -21.3 -22 12/21/2004 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -22 0.2 -21.3 -22.4 12/21/2004 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.7 0.2 -20.8 -22 12/21/2004 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -21.3 0.2 -20.6 -21.7 12/21/2004 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -21.6 0.1 -21.1 -21.8 12/21/2004 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -22 0.1 -21.3 -22.2 12/21/2004 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.8 0.3 -20.8 -22.2 12/21/2004 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -21.4 0.1 -20.8 -21.7 12/21/2004 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -21.3 0 -21.3 -21.7 12/21/2004 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -21.5 0.1 -21.1 -21.7 12/22/2004 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -21.7 0 -21.5 -21.8 12/22/2004 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -21.7 0.1 -21.3 -22 12/22/2004 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -21.6 0.1 -21.3 -21.8 12/22/2004 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -21.6 0 -21.3 -21.7 12/22/2004 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22 0.2 -21.7 -22.4 12/22/2004 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.9 0.1 -21.7 -22.2 12/22/2004 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.7 0 -21.5 -21.8 12/22/2004 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.7 0.1 -21.3 -22 12/22/2004 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.8 0 -21.7 -21.8 12/22/2004 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.8 0 -21.7 -21.8 12/22/2004 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -22 0.1 -21.8 -22.2 12/22/2004 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -22.1 0 -21.8 -22.4 12/22/2004 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -22 0.1 -21.8 -22.4 12/22/2004 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -22.2 0 -22 -22.4 12/22/2004 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.9 0 -21.8 -22 12/22/2004 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -22 0 -21.8 -22.2 12/22/2004 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22 0 -21.8 -22.2 12/22/2004 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22 0 -21.8 -22.2 12/22/2004 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22 0.1 -21.5 -22.2 12/22/2004 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22.1 0 -21.7 -22.2 12/22/2004 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22 0 -21.8 -22.2 12/22/2004 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -21.9 0 -21.3 -22 12/22/2004 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -21.8 0 -21.3 -22 12/22/2004 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22 0 -21.8 -22.2 12/22/2004 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22.3 0 -21.7 -22.5 12/22/2004 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22.1 0 -21.8 -22.4 12/22/2004 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22.1 0 -21.8 -22.2 12/22/2004 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22.3 0 -22 -22.4 12/22/2004 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -22.4 0 -22.2 -22.5 12/22/2004 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -22.6 0 -22.4 -22.7 12/22/2004 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -22.7 0 -22.2 -22.7 12/22/2004 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -22.8 0 -22.4 -22.9 12/22/2004 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -22.9 0.1 -22.4 -23.2 12/22/2004 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -23 0.1 -22.5 -23.2 12/22/2004 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -23.2 0.1 -22.5 -23.4 12/22/2004 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 62 0 0 0 -23.4 0.1 -22.9 -23.6 12/22/2004 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -23.5 0.1 -23 -23.7 12/22/2004 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 61 0 0 0 -23.6 0.1 -23.2 -23.9 12/22/2004 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -23.8 0.1 -23.4 -23.9 12/22/2004 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -24 0.1 -23.6 -24.2 12/22/2004 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 60 0 0 0 -24.2 0 -23.9 -24.4 12/22/2004 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 59 0 0 0 -24.2 0.1 -23.7 -24.4 12/22/2004 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 59 0 0 0 -24.3 0.1 -23.7 -24.4 12/22/2004 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 59 0 0 0 -24.4 0.1 -23.9 -24.6 12/22/2004 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 59 0 0 0 -24.5 0.1 -23.9 -24.6 12/22/2004 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 58 0 0 0 -24.5 0.1 -23.9 -24.6 12/22/2004 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 58 0 0 0 -24.6 0.1 -24.1 -24.9 12/22/2004 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 58 0 0 0 -24.9 0.2 -24.4 -25.1 12/22/2004 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 57 0 0 0 -25 0 -24.6 -25.1 12/22/2004 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 57 0 0 0 -24.9 0 -24.6 -25.1 12/22/2004 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 57 0 0 0 -25 0 -24.7 -25.2 12/22/2004 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 57 0 0 0 -25 0 -24.7 -25.1 12/22/2004 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 57 0 0 0 -25 0 -24.7 -25.2 12/22/2004 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 57 0 0 0 -25.1 0 -24.7 -25.2 12/22/2004 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 56 0 0 0 -25.2 0.1 -24.6 -25.2 12/22/2004 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 55 0 0 0 -25.1 0.1 -24.6 -25.2 12/22/2004 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 57 2 0 0 -25.1 0.2 -24.6 -25.2 12/22/2004 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 50 4 0 0 -24.9 0.2 -24.4 -25.2 12/22/2004 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 43 1 0 0 -25 0.1 -24.6 -25.2 12/22/2004 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 41 1 0 0 -24.9 0.1 -24.6 -25.1 12/22/2004 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 37 2 0 0 -24.9 0 -24.7 -25.1 12/22/2004 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 32 1 0 0 -25 0 -24.7 -25.1 12/22/2004 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 30 0 0 0 -25 0 -24.7 -25.1 12/22/2004 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 29 0 0 0 -24.9 0 -24.7 -25.1 12/22/2004 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 29 0 0 0 -24.9 0 -24.7 -25.1 12/22/2004 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 28 0 0 0 -25 0 -24.6 -25.1 12/22/2004 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 28 0 0 0 -25 0 -24.6 -25.2 12/22/2004 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 28 0 0 0 -25 0 -24.6 -25.2 12/22/2004 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 28 0 0 0 -25 0.1 -24.6 -25.1 12/22/2004 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 28 0 0 0 -25 0 -24.6 -25.2 12/22/2004 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 28 0 0 0 -25.1 0 -24.6 -25.2 12/22/2004 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 27 0 0 0 -25.2 0.1 -24.7 -25.2 12/22/2004 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 26 0 0 0 -25.3 0 -24.9 -25.6 12/22/2004 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 26 0 0 0 -25.5 0.1 -25.1 -25.6 12/22/2004 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 25 0 0 0 -25.5 0.1 -25.1 -25.7 12/22/2004 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 25 0 0 0 -25.6 0.1 -25.1 -25.7 12/22/2004 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 25 0 0 0 -25.5 0.1 -25.1 -25.6 12/22/2004 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 25 0 0 0 -25.5 0.2 -25.1 -25.6 12/22/2004 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 25 0 0 0 -25.6 0.1 -25.1 -25.6 12/22/2004 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 24 0 0 0 -25.5 0.1 -25.1 -25.7 12/22/2004 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 24 0 0 0 -25.6 0.1 -25.1 -25.9 12/22/2004 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 24 0 0 0 -25.6 0.1 -25.1 -25.7 12/22/2004 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 24 0 0 0 -25.6 0.1 -25.1 -25.7 12/22/2004 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 24 0 0 0 -25.5 0.1 -25.1 -25.7 12/22/2004 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 24 0 0 0 -25.6 0.1 -25.2 -25.9 12/22/2004 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 24 0 0 0 -25.6 0.1 -25.1 -25.7 12/22/2004 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 24 0 0 0 -25.5 0.1 -25.1 -25.6 12/22/2004 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 1 305 305 24 0 0 0 -25.5 0.1 -24.9 -25.7 12/22/2004 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 24 0 0 0 -25.6 0.1 -25.1 -25.9 12/22/2004 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 21 2 0 0 -25.7 0.1 -25.2 -25.9 12/22/2004 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 16 1 0 0 -25.7 0.1 -25.2 -25.9 12/22/2004 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 1 305 305 15 0 0 0 -25.6 0.1 -25.1 -25.7 12/22/2004 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 1 305 305 14 0 0 0 -25.5 0.1 -25.1 -25.6 12/22/2004 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 1 305 305 14 0 0 0 -25.4 0.1 -24.7 -25.6 12/22/2004 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 15 0 0 0 -25.2 0.1 -24.6 -25.4 12/22/2004 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 16 0 0 0 -24.9 0.1 -24.6 -25.2 12/22/2004 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 16 0 0 0 -25 0.1 -24.6 -25.1 12/22/2004 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 16 0 0 0 -25 0 -24.6 -25.2 12/22/2004 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 16 0 0 0 -25.2 0.1 -24.6 -25.2 12/22/2004 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 15 0 0 0 -25.3 0.1 -24.7 -25.4 12/22/2004 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 14 0 0 0 -25.2 0.1 -24.7 -25.2 12/22/2004 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 14 0 0 0 -25.2 0.1 -24.6 -25.2 12/22/2004 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 14 0 0 0 -25.1 0 -24.6 -25.2 12/22/2004 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 14 0 0 0 -24.9 0.1 -24.6 -25.1 12/22/2004 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 15 0 0 0 -24.8 0.1 -24.2 -25.1 12/22/2004 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 16 0 0 0 -24.6 0.1 -24.1 -24.7 12/22/2004 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 18 0 0 0 -24.5 0.1 -23.9 -24.6 12/22/2004 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 19 0 0 0 -24.3 0.1 -23.7 -24.6 12/22/2004 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 21 0 0 0 -24.1 0.1 -23.6 -24.4 12/22/2004 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 22 0 0 0 -24 0.1 -23.6 -24.1 12/22/2004 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 23 0 0 0 -24 0 -23.4 -24.1 12/22/2004 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 23 0 0 0 -23.9 0 -23.4 -24.1 12/22/2004 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 25 1 0 0 -23.7 0 -23.2 -23.9 12/22/2004 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 26 0 0 0 -23.6 0.1 -23.2 -23.9 12/22/2004 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 27 0 0 0 -23.5 0 -22.9 -23.7 12/22/2004 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 27 0 0 0 -23.4 0.1 -22.9 -23.4 12/22/2004 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 29 0 0 0 -23.3 0.1 -22.9 -23.4 12/22/2004 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 30 1 0 0 -23.1 0.1 -22.5 -23.4 12/22/2004 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 32 1 0 0 -23 0.1 -22.5 -23.2 12/22/2004 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 35 0 0 0 -22.8 0.1 -22.4 -23 12/22/2004 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 37 1 0 0 -22.7 0.1 -22.5 -22.9 12/22/2004 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 43 2 0 0 -22.3 0.1 -22 -22.5 12/22/2004 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 47 1 0 0 -22.2 0 -22 -22.4 12/22/2004 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 50 1 0 0 -22.1 0.1 -21.8 -22.2 12/22/2004 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 55 1 0 0 -21.9 0 -21.8 -22 12/22/2004 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 59 1 0 0 -21.6 0.1 -21.3 -21.8 12/22/2004 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 63 0 0 0 -21.4 0.1 -21 -21.5 12/22/2004 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.3 0.1 -20.8 -21.7 12/22/2004 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -21.2 0 -20.8 -21.3 12/22/2004 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -21.3 0 -21.3 -21.3 12/22/2004 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21.3 0 -20.8 -21.3 12/22/2004 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 64 0 0 0 -21 0.2 -20.2 -21.3 12/22/2004 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.8 0 -20.2 -21 12/22/2004 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.8 0 -20.4 -21 12/22/2004 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.6 0 -20.4 -21 12/22/2004 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.4 0.1 -20.1 -20.8 12/22/2004 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 65 0 0 0 -20.2 0 -20.1 -20.4 12/22/2004 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -20 0.1 -19.7 -20.2 12/22/2004 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -19.8 0.1 -19.5 -20.1 12/22/2004 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -19.8 0.2 -19.5 -20.1 12/22/2004 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -20.1 0.1 -19.9 -20.1 12/22/2004 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -19.9 0.1 -19.5 -20.1 12/22/2004 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -20 0.1 -19.5 -20.1 12/22/2004 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -19.7 0 -19.3 -19.9 12/23/2004 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -19.7 0.1 -19 -19.9 12/23/2004 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -19.5 0.1 -19 -19.5 12/23/2004 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -19.2 0.1 -18.8 -19.5 12/23/2004 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -19.1 0.1 -18.4 -19.3 12/23/2004 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -19 0.1 -18.4 -19.2 12/23/2004 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -19.1 0 -18.4 -19.2 12/23/2004 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -18.9 0.1 -18.4 -19 12/23/2004 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -18.9 0.1 -18.4 -19 12/23/2004 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -18.9 0.1 -18.4 -19 12/23/2004 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -18.8 0.1 -18.2 -19 12/23/2004 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -18.7 0.1 -18.1 -18.8 12/23/2004 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -18.5 0 -18.2 -18.6 12/23/2004 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -18.2 0 -18.1 -18.4 12/23/2004 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -18.3 0 -18.1 -18.4 12/23/2004 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -18.1 0 -18.1 -18.4 12/23/2004 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -18 0 -17.7 -18.2 12/23/2004 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -17.8 0 -17.5 -18.1 12/23/2004 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.8 0 -17.7 -18.1 12/23/2004 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.7 0 -17.5 -17.9 12/23/2004 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -17.5 0 -17.5 -17.7 12/23/2004 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -17.6 0 -17.5 -17.9 12/23/2004 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -17.6 0 -17.5 -17.7 12/23/2004 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -17.6 0 -17.5 -17.7 12/23/2004 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -17.6 0 -17.5 -17.9 12/23/2004 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -17.6 0 -17.3 -17.9 12/23/2004 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -17.6 0 -17.1 -17.9 12/23/2004 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -17.7 0 -17.1 -17.9 12/23/2004 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -17.7 0 -17.3 -17.9 12/23/2004 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -17.7 0 -17.1 -17.9 12/23/2004 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -17.6 0 -16.9 -17.9 12/23/2004 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -17.6 0 -17.5 -17.9 12/23/2004 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -17.5 0 -17.5 -17.7 12/23/2004 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -17.6 0 -17.5 -17.7 12/23/2004 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -17.5 0 -17.5 -17.7 12/23/2004 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.6 0 -17.5 -17.9 12/23/2004 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.6 0 -17.5 -17.7 12/23/2004 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.5 0 -17.5 -17.7 12/23/2004 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.5 0 -17.3 -17.7 12/23/2004 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.6 0 -17.5 -17.9 12/23/2004 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -17.7 0 -17.5 -17.9 12/23/2004 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.6 0 -17.5 -17.7 12/23/2004 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.5 0 -17.5 -17.5 12/23/2004 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.5 0 -17.3 -17.7 12/23/2004 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.5 0 -17.1 -17.7 12/23/2004 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.4 0 -17.1 -17.5 12/23/2004 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -17.3 0 -17.1 -17.5 12/23/2004 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.5 0 -17.3 -17.7 12/23/2004 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.5 0 -17.3 -17.7 12/23/2004 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.4 0 -17.1 -17.5 12/23/2004 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -17.2 0 -16.9 -17.5 12/23/2004 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -17.2 0 -16.9 -17.3 12/23/2004 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -17.1 0 -16.9 -17.3 12/23/2004 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -16.9 0 -16.9 -17.1 12/23/2004 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -16.9 0 -16.9 -16.9 12/23/2004 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -16.9 0 -16.7 -16.9 12/23/2004 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -16.9 0 -16.6 -16.9 12/23/2004 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16.7 0 -16.4 -16.9 12/23/2004 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -16.7 0 -16.4 -16.9 12/23/2004 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16.5 0 -16.4 -16.6 12/23/2004 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16.4 0 -16.2 -16.6 12/23/2004 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16.4 0 -16.4 -16.6 12/23/2004 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16.4 0 -16.4 -16.6 12/23/2004 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16.5 0 -16.4 -16.6 12/23/2004 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16.6 0 -16.4 -16.7 12/23/2004 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16.5 0 -16.4 -16.6 12/23/2004 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16.4 0 -16.4 -16.6 12/23/2004 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -16.3 0 -16 -16.6 12/23/2004 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -16.2 0 -16 -16.4 12/23/2004 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -16 0 -15.8 -16.2 12/23/2004 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -15.9 0 -15.8 -16 12/23/2004 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -15.8 0 -15.8 -16 12/23/2004 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -16 0 -15.8 -16.2 12/23/2004 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -16 0 -15.8 -16.2 12/23/2004 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -15.9 0 -15.8 -16 12/23/2004 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 1 0 0 -15.9 0 -15.8 -16 12/23/2004 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16 0 -15.8 -16.2 12/23/2004 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -16 0 -15.8 -16 12/23/2004 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16 0 -15.8 -16.2 12/23/2004 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16 0 -15.8 -16.2 12/23/2004 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16.1 0 -15.8 -16.2 12/23/2004 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -16 0 -15.8 -16.2 12/23/2004 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -16 0 -15.8 -16.2 12/23/2004 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -16 0 -15.8 -16.2 12/23/2004 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -16 0 -15.8 -16.2 12/23/2004 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -15.9 0 -15.8 -16.2 12/23/2004 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.9 0 -15.8 -16 12/23/2004 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.9 0 -15.6 -16 12/23/2004 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.8 0 -15.6 -16 12/23/2004 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.8 0 -15.6 -16 12/23/2004 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.9 0 -15.8 -16 12/23/2004 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.8 0 -15.6 -16 12/23/2004 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.9 0 -15.6 -16 12/23/2004 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.8 0 -15.6 -16 12/23/2004 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.8 0 -15.6 -15.8 12/23/2004 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.7 0 -15.6 -15.8 12/23/2004 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.7 0 -15.6 -15.8 12/23/2004 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.8 0 -15.6 -16 12/23/2004 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.8 0 -15.8 -16 12/23/2004 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.8 0 -15.6 -16 12/23/2004 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.8 0 -15.6 -16 12/23/2004 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.8 0 -15.6 -16 12/23/2004 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.8 0 -15.6 -16 12/23/2004 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.8 0 -15.6 -16 12/23/2004 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.8 0 -15.6 -15.8 12/23/2004 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.8 0 -15.6 -15.8 12/23/2004 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.8 0 -15.6 -15.8 12/23/2004 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.6 0 -15.4 -15.8 12/23/2004 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.6 0 -15.2 -15.6 12/23/2004 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.4 0 -15 -15.6 12/23/2004 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.4 0 -15 -15.6 12/23/2004 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.3 0 -15 -15.4 12/23/2004 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.2 0 -15 -15.4 12/23/2004 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.2 0 -14.8 -15.2 12/23/2004 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.1 0 -14.8 -15.2 12/23/2004 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -15.1 0 -14.6 -15 12/23/2004 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.1 0 -14.6 -15 12/23/2004 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15 0 -14.6 -15 12/23/2004 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15.1 0.1 -14.6 -15.2 12/23/2004 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15 0 -14.6 -15 12/23/2004 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -14.9 0 -14.6 -15 12/23/2004 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -14.9 0 -14.6 -15 12/23/2004 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -15 0 -14.6 -15 12/23/2004 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -14.8 0 -14.6 -15 12/23/2004 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -15.1 0 -14.8 -15.2 12/23/2004 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -14.9 0 -14.6 -15 12/23/2004 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -15.1 0.1 -14.6 -15.4 12/23/2004 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -15.1 0 -14.8 -15.4 12/23/2004 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -14.8 0 -14.6 -15 12/23/2004 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -15.8 0.4 -14.8 -16.4 12/23/2004 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.8 0.1 -15.4 -16 12/23/2004 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.8 0.1 -15.6 -16 12/23/2004 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.6 0 -15.4 -15.8 12/23/2004 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -16.1 0.3 -15.6 -16.6 12/23/2004 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 66 0 0 0 -15.8 0.4 -15 -16.6 12/23/2004 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.1 0.1 -14.8 -15.2 12/23/2004 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.2 0 -14.8 -15.2 12/23/2004 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.3 0 -15 -15.6 12/23/2004 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.6 0.3 -15.2 -16.2 12/23/2004 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -16 0.1 -15.6 -16.4 12/23/2004 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.6 0.1 -15.2 -15.8 12/23/2004 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.5 0 -15.2 -15.6 12/23/2004 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.8 0.1 -15.2 -16 12/23/2004 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.8 0 -15.6 -16 12/23/2004 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.9 0 -15.6 -16.2 12/24/2004 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.9 0 -15.8 -16 12/24/2004 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.9 0 -15.6 -16.2 12/24/2004 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 67 0 0 0 -15.7 0.1 -15.6 -15.8 12/24/2004 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -15.8 0 -15.4 -16 12/24/2004 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -15.5 0 -15.2 -15.6 12/24/2004 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -15.6 0 -15.2 -15.8 12/24/2004 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -15.4 0.1 -15 -15.6 12/24/2004 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 68 0 0 0 -15.6 0 -15.2 -15.8 12/24/2004 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -15.3 0 -15 -15.6 12/24/2004 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -15.4 0 -15.2 -15.6 12/24/2004 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -15.3 0 -15 -15.6 12/24/2004 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -15.2 0 -15 -15.2 12/24/2004 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -14.8 0.1 -14.4 -15 12/24/2004 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 69 0 0 0 -14.7 0 -14.4 -14.8 12/24/2004 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -14.6 0.1 -14.3 -14.8 12/24/2004 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 70 0 0 0 -14.4 0 -14.3 -14.6 12/24/2004 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -14.2 0 -13.9 -14.4 12/24/2004 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 71 0 0 0 -14.4 0 -14.3 -14.4 12/24/2004 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -14.3 0 -13.9 -14.4 12/24/2004 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -14.1 0 -13.7 -14.3 12/24/2004 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -14.2 0 -13.7 -14.3 12/24/2004 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -14.2 0 -13.9 -14.4 12/24/2004 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -14.3 0.1 -13.9 -14.6 12/24/2004 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 71 0 0 0 -14.3 0 -13.9 -14.4 12/24/2004 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -14.2 0 -13.9 -14.4 12/24/2004 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -13.8 0.1 -13.7 -14.3 12/24/2004 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 72 0 0 0 -13.6 0 -13.3 -13.7 12/24/2004 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -13.2 0.1 -12.9 -13.7 12/24/2004 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 73 0 0 0 -13 0 -12.9 -13.3 12/24/2004 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 74 0 0 0 -13 0 -12.9 -13.1 12/24/2004 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 74 0 0 0 -12.7 0.1 -12.5 -12.9 12/24/2004 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -12.2 0.2 -11.9 -12.7 12/24/2004 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 75 0 0 0 -12 0 -11.7 -12.1 12/24/2004 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 76 0 0 0 -11.6 0.1 -11.3 -12.1 12/24/2004 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 76 0 0 0 -11.3 0.2 -10.7 -11.5 12/24/2004 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 77 0 0 0 -10.7 0 -10.4 -10.9 12/24/2004 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 77 0 0 0 -10.7 0.1 -10.4 -10.9 12/24/2004 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 77 0 0 0 -11.2 0.1 -10.9 -11.5 12/24/2004 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 77 0 0 0 -11.1 0 -10.9 -11.3 12/24/2004 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 77 0 0 0 -10.9 0 -10.7 -11.1 12/24/2004 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 77 0 0 0 -11 0 -10.9 -11.3 12/24/2004 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 77 0 0 0 -10.8 0 -10.4 -10.9 12/24/2004 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 77 0 0 0 -10.5 0 -10.4 -10.7 12/24/2004 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 78 0 0 0 -10.4 0 -10 -10.7 12/24/2004 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 77 0 0 0 -10.8 0 -10.4 -10.9 12/24/2004 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 77 0 0 0 -10.9 0 -10.4 -11.1 12/24/2004 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 76 0 0 0 -10.9 0 -10.7 -11.1 12/24/2004 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 76 0 0 0 -11 0 -10.9 -11.3 12/24/2004 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 76 0 0 0 -10.8 0.1 -10.4 -11.1 12/24/2004 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 77 0 0 0 -10.3 0.1 -10 -10.4 12/24/2004 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 76 0 0 0 -10.7 0.3 -10.2 -11.3 12/24/2004 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 75 0 0 0 -11.4 0.1 -10.9 -11.7 12/24/2004 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 74 0 0 0 -11.8 0.1 -11.5 -12.1 12/24/2004 08:50:00 4.1 5.1 15.6 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 35 305 74 0 0 0 -11 0.5 -10.4 -12.1 12/24/2004 09:00:00 10.6 1.6 14.5 6.1 8.5 4.5 14.1 0.4 0.4 0 0.4 0.4 35 0 35 305 76 0 76 0 -10 0.3 -9.4 -10.9 12/24/2004 09:10:00 9.9 1.7 13.3 5.3 10.8 0.8 13.3 8 0.4 0 0.4 0.4 35 0 35 305 74 0 76 0 -11 0.5 -9.8 -11.5 12/24/2004 09:20:00 12 1.1 14.5 8 11.6 0.8 13.3 9.1 0.4 0 0.4 0.4 35 0 35 305 73 0 74 0 -11.6 0 -11.3 -11.9 12/24/2004 09:30:00 13.4 0.9 14.9 9.9 12.7 0.5 13.7 10.7 0.4 0 0.4 0.4 35 0 35 305 74 0 73 0 -11.5 0 -11.3 -11.7 12/24/2004 09:40:00 13.7 0.5 14.9 12.2 12.6 0.5 13.7 11.1 0.4 0 0.4 0.4 35 0 35 305 74 0 73 0 -11.6 0 -11.5 -11.9 12/24/2004 09:50:00 13.1 0.5 14.5 11.5 12.1 0.4 13.3 11.1 0.4 0 0.4 0.4 35 0 35 305 74 0 74 0 -11.5 0 -11.3 -11.7 12/24/2004 10:00:00 13 0.5 14.1 11.5 11.9 0.5 13 10.3 0.4 0 0.4 0.4 35 0 35 305 74 0 74 0 -11.4 0 -11.1 -11.5 12/24/2004 10:10:00 13.1 0.4 14.1 11.8 12.1 0.5 13 10.3 0.4 0 0.4 0.4 35 0 35 305 74 0 74 0 -11.1 0 -10.9 -11.3 12/24/2004 10:20:00 13 0.6 14.1 10.3 12 0.6 13.7 9.9 0.4 0 0.4 0.4 35 0 35 305 74 0 74 0 -11.1 0 -10.9 -11.3 12/24/2004 10:30:00 13.3 0.7 14.5 11.1 12.1 0.5 13.3 10.7 0.4 0 0.4 0.4 35 0 35 305 74 0 74 0 -10.8 0.1 -10.4 -11.1 12/24/2004 10:40:00 13.3 0.7 14.9 11.1 12.1 0.6 13.3 10.3 0.4 0 0.4 0.4 35 0 35 305 75 0 75 0 -10.5 0.1 -10.2 -10.9 12/24/2004 10:50:00 13 0.6 14.1 11.1 12.3 0.6 13.7 10.7 0.4 0 0.4 0.4 35 0 35 305 75 0 76 0 -10.2 0 -10 -10.4 12/24/2004 11:00:00 12.8 0.5 13.7 11.1 12.1 0.5 13.3 10.7 0.4 0 0.4 0.4 35 0 35 305 75 0 76 0 -10.2 0 -10 -10.4 12/24/2004 11:10:00 12.9 0.6 13.7 11.1 12.3 0.6 13.3 10.3 0.4 0 0.4 0.4 35 0 35 305 76 0 76 0 -9.9 0 -9.8 -10.2 12/24/2004 11:20:00 12.3 0.6 13.3 10.3 11.8 0.6 13 10.3 0.4 0 0.4 0.4 35 0 35 305 76 0 76 0 -9.7 0 -9.6 -9.8 12/24/2004 11:30:00 12.3 0.8 13.7 9.9 11.8 0.7 13.3 9.9 0.4 0 0.7 0.4 35 0 35 305 76 0 76 0 -9.8 0 -9.6 -10 12/24/2004 11:40:00 12 0.6 13.7 9.9 11.5 0.6 13 9.5 0.4 0 0.4 0.4 35 0 35 305 76 0 76 0 -9.9 0 -9.8 -10 12/24/2004 11:50:00 11.6 0.6 13.3 9.5 11.1 0.6 12.6 8.8 0.4 0 0.4 0.4 35 0 35 305 76 0 76 0 -9.7 0.1 -9.2 -10 12/24/2004 12:00:00 11.4 0.7 13 8.8 11 0.7 12.6 8.4 0.4 0 0.4 0.4 35 0 35 305 77 0 77 0 -9.1 0.1 -8.8 -9.6 12/24/2004 12:10:00 11.2 0.7 13.3 8.8 10.8 0.7 12.6 8.8 0.4 0 0.4 0.4 35 0 35 305 78 0 77 0 -8.9 0.1 -8.4 -9.2 12/24/2004 12:20:00 10.6 1 13 7.6 10.2 0.9 12.2 7.6 0.4 0 0.4 0.4 35 0 35 305 78 0 78 0 -8.5 0 -8.2 -8.8 12/24/2004 12:30:00 9.4 1 13 6.1 9.1 0.8 11.8 6.1 0.4 0 0.4 0.4 35 0 35 305 79 0 79 0 -8.3 0 -8.2 -8.4 12/24/2004 12:40:00 9.4 1.3 13 6.5 9.1 1.2 13 6.8 0.4 0 0.4 0.4 35 0 35 305 80 0 80 0 -8 0.2 -7.3 -8.4 12/24/2004 12:50:00 9.6 1.4 13 6.1 9.1 1.2 11.8 6.1 0.4 0 0.4 0.4 35 0 35 305 80 0 80 0 -7.4 0 -7.1 -7.7 12/24/2004 13:00:00 9.9 1.1 13 6.8 9.6 1.1 12.2 6.5 0.4 0 0.4 0.4 35 0 35 305 81 0 82 0 -7 0.2 -6.4 -7.3 12/24/2004 13:10:00 9.3 1.3 12.6 4.9 9.1 1.1 11.8 5.7 0.4 0 0.4 0.4 35 0 35 305 82 0 82 0 -6.5 0 -6.2 -6.7 12/24/2004 13:20:00 10.1 1.7 14.9 6.5 9.8 1.4 13.3 6.8 0.4 0 0.4 0.4 35 0 35 305 83 0 83 0 -5.9 0.1 -5.8 -6.4 12/24/2004 13:30:00 9.7 1.7 13.3 4.9 9.8 1.4 13.3 6.5 0.4 0 0.4 0.4 35 0 35 305 83 0 83 0 -5.6 0 -5.6 -5.8 12/24/2004 13:40:00 9.7 1.5 14.9 5.7 9.5 1.3 13 5.7 0.4 0 0.4 0.4 35 0 35 305 84 0 84 0 -5.5 0 -5.3 -5.6 12/24/2004 13:50:00 9.6 1.5 13.3 6.5 9.5 1.4 13 6.5 0.4 0 0.4 0.4 35 0 36 305 84 0 84 0 -5.5 0 -5.6 -5.8 12/24/2004 14:00:00 10.9 1.2 13.3 7.6 10.6 1.2 14.5 8 0.4 0 0.4 0.4 35 0 36 305 83 0 83 0 -5.5 0 -5.1 -5.8 12/24/2004 14:10:00 11 1.4 15.3 6.8 10.8 1.3 14.5 7.6 0.4 0 0.4 0.4 35 0 36 305 83 0 83 0 -5.5 0 -5.1 -5.8 12/24/2004 14:20:00 9.8 1.6 13.3 6.1 9.7 1.5 13.3 6.1 0.4 0 0.4 0.4 35 0 35 305 84 0 84 0 -5.2 0 -4.9 -5.6 12/24/2004 14:30:00 11.8 1.9 16.8 7.6 11.4 1.7 16.1 7.2 0.4 0 0.4 0.4 35 0 36 305 84 0 84 0 -4.9 0 -4.7 -5.1 12/24/2004 14:40:00 12.4 1.8 16.8 8 12.1 1.7 16.4 8.4 0.4 0 0.4 0.4 36 0 36 305 84 0 84 0 -4.7 0 -4.5 -4.9 12/24/2004 14:50:00 13.4 1.8 17.9 7.6 12.9 1.7 17.6 7.2 0.4 0 0.4 0.4 87 56 148 305 84 0 84 0 -4.7 0 -4.5 -4.9 12/24/2004 15:00:00 13.6 2.1 18.7 8.4 13.4 1.9 18.3 8 0.4 0 0.4 0.4 149 10 137 305 84 0 84 0 -4.6 0 -4.5 -4.7 12/24/2004 15:10:00 13.3 2.1 19.1 8.8 12.9 2.1 18.3 7.6 0.4 0 0.4 0.4 148 10 144 305 84 0 84 0 -4.5 0 -4.5 -4.7 12/24/2004 15:20:00 13.5 1.8 19.9 9.1 13.1 1.7 18.3 8.8 0.4 0 0.4 0.4 147 12 139 305 84 0 84 0 -4.4 0 -4 -4.7 12/24/2004 15:30:00 14.1 2 19.1 9.1 13.8 1.9 18.7 8.4 0.4 0 0.4 0.4 149 11 144 305 83 0 83 0 -4.4 0 -4.2 -4.5 12/24/2004 15:40:00 14.4 2.2 20.6 8.8 14 1.9 19.9 8.4 0.4 0 0.4 0.4 148 11 145 305 83 0 84 0 -4.4 0 -4.2 -4.5 12/24/2004 15:50:00 15 2.3 19.9 8.8 14.5 2.2 19.5 8.8 0.4 0 0.4 0.4 145 11 134 305 83 0 83 0 -4.4 0 -4.5 -4.7 12/24/2004 16:00:00 14.7 2.2 21 9.5 14.3 2 19.5 8.8 0.4 0 0.4 0.4 143 11 140 305 83 0 82 0 -4.5 0 -4 -4.7 12/24/2004 16:10:00 14.9 2.3 21 9.9 14.4 2.2 20.6 9.9 0.4 0 0.4 0.4 143 11 137 305 82 0 82 0 -4.5 0 -4.5 -4.7 12/24/2004 16:20:00 14.6 1.9 20.2 9.9 14.3 1.8 19.5 9.9 0.4 0 0.4 0.4 143 12 147 305 82 0 82 0 -4.5 0 -4.5 -4.7 12/24/2004 16:30:00 14.4 2.1 20.6 8.8 14.1 1.9 18.7 9.9 0.4 0 0.4 0.4 143 12 147 305 82 0 82 0 -4.5 0 -4.5 -4.7 12/24/2004 16:40:00 13.7 2 19.9 8.8 13.5 2 19.1 9.1 0.4 0 0.4 0.4 144 11 143 305 82 0 82 0 -4.5 0 -4.5 -4.7 12/24/2004 16:50:00 14 2.2 19.1 8.8 13.7 2.1 18.3 9.1 0.4 0 0.4 0.4 141 11 138 305 83 0 83 0 -4.5 0 -4.5 -4.7 12/24/2004 17:00:00 14.2 2.1 19.5 9.1 13.9 2 18.3 9.5 0.4 0 0.4 0.4 141 11 155 305 83 0 83 0 -4.4 0 -4 -4.5 12/24/2004 17:10:00 14.9 2.4 22.1 9.1 14.7 2.2 22.9 9.5 0.4 0 0.4 0.4 140 10 135 305 83 0 82 0 -4.4 0 -4 -4.5 12/24/2004 17:20:00 15 2.3 21.4 10.3 14.6 2.3 21.4 9.9 0.4 0 0.4 0.4 141 11 152 305 83 0 83 0 -4.3 0 -3.8 -4.5 12/24/2004 17:30:00 16.5 2.2 22.6 11.1 16.1 2.3 22.6 10.7 0.4 0 0.4 0.4 139 11 123 305 83 0 84 0 -4.2 0 -4 -4.5 12/24/2004 17:40:00 16.1 2.4 22.9 10.7 15.7 2.3 20.6 11.1 0.4 0 0.4 0.4 142 11 143 305 84 0 84 0 -4.2 0 -3.8 -4.2 12/24/2004 17:50:00 15.7 2.3 21.8 9.9 15.4 2.2 20.6 10.7 0.4 0 0.4 0.4 144 10 136 305 84 0 84 0 -4.2 0 -4 -4.2 12/24/2004 18:00:00 17.2 2.3 23.7 11.8 16.7 2.3 22.6 10.7 0.4 0 0.7 0.4 145 10 145 305 84 0 84 0 -4.1 0 -3.8 -4.2 12/24/2004 18:10:00 16.9 2.5 23.3 10.7 16.5 2.3 23.3 11.1 0.4 0 0.4 0.4 144 10 148 305 83 0 83 0 -4.1 0 -4 -4.2 12/24/2004 18:20:00 17.5 2.8 26 10.3 17.1 2.6 25.6 11.8 0.4 0 0.4 0.4 142 10 140 305 83 0 83 0 -4.2 0 -3.8 -4.2 12/24/2004 18:30:00 17.3 2.6 23.7 11.5 16.8 2.5 23.3 11.1 0.4 0 0.4 0.4 144 11 149 305 84 0 84 0 -4.2 0 -4 -4.2 12/24/2004 18:40:00 17 2.5 24.4 11.5 16.5 2.3 23.7 11.5 0.4 0 0.4 0.4 145 11 139 305 84 0 84 0 -4.1 0 -4 -4.2 12/24/2004 18:50:00 16.9 2.4 24 11.1 16.6 2.3 23.3 11.8 0.4 0 0.4 0.4 146 10 155 305 85 1 84 0 -4.1 0 -4 -4.2 12/24/2004 19:00:00 17.1 2.6 23.7 10.3 16.7 2.5 22.9 10.7 0.4 0 0.4 0.4 145 10 147 305 86 0 86 0 -4 0 -3.8 -4 12/24/2004 19:10:00 18.4 2.9 25.6 11.5 18 2.7 25.2 11.8 0.4 0 0.4 0.4 145 10 147 305 87 0 87 0 -4 0 -3.8 -4 12/24/2004 19:20:00 17.9 2.5 24.8 11.1 17.5 2.4 24.4 10.7 0.4 0 0.4 0.4 147 10 161 305 87 0 86 0 -3.9 0 -3.8 -4 12/24/2004 19:30:00 18.3 2.7 26.3 11.8 17.8 2.5 25.6 12.2 0.4 0 0.4 0.4 148 10 155 305 87 0 87 0 -3.9 0 -3.8 -4 12/24/2004 19:40:00 17.9 2.6 23.7 11.8 17.6 2.3 22.6 11.8 0.4 0 0.7 0.4 150 10 152 305 87 0 87 0 -3.7 0 -3.6 -3.8 12/24/2004 19:50:00 20 3.1 26.8 10.7 19.4 2.6 25.6 11.1 0.4 0 0.4 0.4 149 9 147 305 87 0 87 0 -3.6 0 -3.3 -3.8 12/24/2004 20:00:00 19.7 2.8 28.7 12.2 19.4 2.5 27.5 13.3 0.4 0 0.4 0.4 150 10 138 305 88 0 87 0 -3.5 0 -3.1 -3.6 12/24/2004 20:10:00 19.9 2.9 27.5 11.5 19.6 2.6 27.5 13.7 0.4 0 0.4 0.4 150 9 156 305 89 0 88 0 -3.3 0 -3.1 -3.6 12/24/2004 20:20:00 19.4 2.9 27.5 11.8 19.2 2.7 26 11.8 0.4 0 0.4 0.4 150 11 145 305 90 0 90 0 -3.2 0 -2.7 -3.3 12/24/2004 20:30:00 19.7 2.8 26 13 19.5 2.6 24.8 12.6 0.4 0 0.4 0.4 151 10 152 305 90 0 90 0 -3.1 0 -2.7 -3.3 12/24/2004 20:40:00 19.7 2.9 26.8 13 19.5 2.7 26.8 12.6 0.4 0 0.4 0.4 151 10 156 305 90 0 90 0 -3 0 -2.7 -3.1 12/24/2004 20:50:00 19.2 3.2 27.1 12.2 19.2 2.8 26.3 13.3 0.4 0 0.4 0.4 154 10 149 305 91 1 90 0 -3 0 -2.7 -3.1 12/24/2004 21:00:00 17.2 2.9 24.4 10.7 17.4 2.6 23.3 11.5 0.4 0 0.7 0.4 156 12 154 305 92 0 92 0 -2.9 0 -2.7 -3.1 12/24/2004 21:10:00 16.5 2.8 23.3 10.3 16.7 2.7 22.9 10.7 0.4 0 0.4 0.4 156 12 152 305 92 0 92 0 -2.8 0 -2.7 -2.9 12/24/2004 21:20:00 16.1 2.9 24.8 9.9 16.4 2.5 24.4 9.9 0.4 0 0.4 0.4 158 12 152 305 92 0 92 0 -2.7 0 -2.2 -2.7 12/24/2004 21:30:00 16 2.9 24 8.8 16.3 2.6 23.7 10.3 0.4 0 0.4 0.4 158 11 149 305 92 0 92 0 -2.7 0 -2.4 -2.7 12/24/2004 21:40:00 15.7 2.6 22.1 9.5 16.2 2.4 22.6 11.1 0.4 0 0.4 0.4 159 11 166 305 93 0 93 0 -2.6 0 -2 -2.7 12/24/2004 21:50:00 16.5 2.6 24 11.5 16.7 2.3 23.3 11.5 0.4 0 0.7 0.4 159 11 158 305 93 0 93 0 -2.4 0 -2.2 -2.7 12/24/2004 22:00:00 15.8 2.4 23.7 10.7 16.3 2.1 22.9 9.9 0.4 0 0.4 0.4 160 11 152 305 94 0 94 0 -2.2 0 -1.8 -2.4 12/24/2004 22:10:00 16 2.7 22.6 10.3 16.5 2.3 21.8 11.1 0.4 0 0.4 0.4 160 10 159 305 94 0 94 0 -2.1 0 -1.8 -2.2 12/24/2004 22:20:00 15 2.4 23.7 9.5 16 1.9 22.1 11.5 0.4 0 0.4 0.4 162 9 159 305 105 4 107 0 -2 0 -1.5 -2 12/24/2004 22:30:00 15.3 2 20.6 9.9 16.9 1.7 21 12.6 0.4 0 0.4 0.4 166 8 161 305 112 0 112 0 -1.8 0 -1.8 -2 12/24/2004 22:40:00 16.5 2.2 24 11.1 17.6 1.8 23.3 13 0.4 0 0.4 0.4 163 7 155 305 114 2 112 0 -1.6 0 -1.5 -1.8 12/24/2004 22:50:00 17.2 2.4 24 11.1 18.5 2.1 25.6 12.6 0.4 0 0.4 0.4 162 8 162 305 122 1 123 0 -1.5 0 -1.1 -1.8 12/24/2004 23:00:00 17.4 2.3 23.7 12.2 19.6 1.7 23.7 15.3 0.4 0 0.4 0.4 164 6 163 305 122 1 122 0 -1.3 0 -0.8 -1.5 12/24/2004 23:10:00 17.6 2.2 22.9 11.8 19.8 1.5 23.7 15.6 0.4 0 0.7 0.4 165 6 158 305 127 3 126 0 -1.2 0 -0.8 -1.3 12/24/2004 23:20:00 16.9 2 22.6 12.6 19.1 1.5 22.1 14.5 0.4 0 0.4 0.4 164 5 156 305 127 2 129 0 -1.1 0 -0.6 -1.3 12/24/2004 23:30:00 16.2 1.7 21.4 13 18.9 1.2 21.8 15.6 0.4 0 0.4 0.4 165 5 163 305 125 1 126 0 -1 0 -0.8 -1.1 12/24/2004 23:40:00 14.7 1.7 21 11.1 17.7 1.5 21.8 13.3 0.4 0 0.4 0.4 167 5 160 305 125 1 125 0 -0.9 0 -0.4 -1.1 12/24/2004 23:50:00 14.9 1.4 19.5 11.5 18.1 1.3 21.8 14.5 0.4 0 0.4 0.4 167 5 171 305 143 38 127 0 -0.8 0 -0.4 -1.1 12/25/2004 00:00:00 14.5 1.3 18.7 11.5 18.1 1.3 21 14.5 0.4 0 0.4 0.4 168 4 153 305 212 3 214 0 -0.7 0 -0.1 -0.8 12/25/2004 00:10:00 14.6 1.5 18.7 11.1 18.1 1.3 21 13.7 0.4 0 0.4 0.4 168 5 165 305 216 1 215 0 -0.6 0 0.1 -0.6 12/25/2004 00:20:00 14.7 1.4 18.7 10.3 18.6 1.5 22.1 14.5 0.4 0 0.7 0.4 169 5 165 305 222 4 226 0 -0.4 0.1 0.1 -0.6 12/25/2004 00:30:00 14.7 1.4 19.5 9.9 18.4 1.5 22.6 14.5 0.4 0 0.7 0.4 170 5 171 305 237 10 227 0 -0.3 0 0.3 -0.4 12/25/2004 00:40:00 14.2 1.4 17.9 9.9 17.9 1.6 22.9 13.7 0.4 0 0.4 0.4 170 5 169 305 246 3 248 0 -0.3 0 0.3 -0.4 12/25/2004 00:50:00 13.5 1.4 17.6 10.3 17.1 1.6 21 13 0.4 0 0.4 0.4 171 6 187 305 238 2 238 0 -0.2 0 0.3 -0.4 12/25/2004 01:00:00 12.5 1.3 17.2 8.8 15.5 1.4 19.5 11.8 0.4 0 0.4 0.4 172 6 181 305 225 11 239 0 -0.1 0 0.3 -0.4 12/25/2004 01:10:00 12.1 1.4 16.4 8.8 15.3 1.5 19.5 11.8 0.4 0 0.7 0.4 172 6 188 305 212 5 217 0 -0.1 0 0.3 -0.4 12/25/2004 01:20:00 11.6 1.4 16.1 8.4 14.3 1.2 17.9 10.7 0.4 0 0.4 0.4 173 6 184 305 208 12 217 0 -0.1 0 0.3 -0.4 12/25/2004 01:30:00 11.2 1.2 15.3 8.8 14.1 1 17.2 11.5 0.4 0 0.4 0.4 173 7 186 305 166 8 154 0 0 0 0.6 -0.1 12/25/2004 01:40:00 10.7 1.3 14.5 6.8 13.9 1.1 17.2 10.7 0.4 0 0.4 0.4 172 6 180 305 152 1 151 0 0 0 0.6 -0.1 12/25/2004 01:50:00 10.8 1.2 14.1 7.6 13.5 1.1 16.4 10.7 0.4 0 0.4 0.4 172 6 183 305 146 5 154 0 -0.1 0 0.3 -0.1 12/25/2004 02:00:00 10.6 1.5 15.6 6.8 12.3 1.2 16.4 8.8 0.4 0 0.4 0.4 173 6 195 305 140 1 143 0 -0.1 0 0.3 -0.4 12/25/2004 02:10:00 9.8 1.3 13.3 6.8 11.5 1 14.5 8.4 0.4 0 0.4 0.4 167 6 168 305 142 1 143 0 -0.2 0 0.3 -0.4 12/25/2004 02:20:00 10 1.5 14.1 6.5 11.7 1 15.3 8.8 0.4 0 0.4 0.4 164 6 171 305 131 5 128 0 -0.2 0 0.3 -0.4 12/25/2004 02:30:00 9.6 1.5 13.7 6.8 11.4 1 14.5 8.8 0.4 0 0.4 0.4 161 6 169 305 116 2 116 0 -0.1 0 0.3 -0.4 12/25/2004 02:40:00 9.3 1.3 13.7 6.1 11 0.9 13.7 9.1 0.4 0 0.4 0.4 158 6 165 305 110 1 110 0 -0.1 0 0.3 -0.4 12/25/2004 02:50:00 9.1 1.2 12.6 6.5 11 0.8 13.3 8.8 0.4 0 0.4 0.4 154 6 171 305 110 1 109 0 -0.1 0 0.3 -0.4 12/25/2004 03:00:00 9.4 1 12.6 6.8 12.3 1 14.5 9.9 0.4 0 0.4 0.4 151 5 161 305 110 1 111 0 -0.1 0 0.3 -0.1 12/25/2004 03:10:00 9.3 1 13.7 6.8 12.2 1 14.5 9.1 0.4 0 0.4 0.4 152 5 160 305 112 1 112 0 -0.1 0 0.1 -0.1 12/25/2004 03:20:00 9.6 1.2 13.3 6.5 12.1 1.1 15.6 9.1 0.4 0 0.4 0.4 155 6 160 305 115 1 117 0 -0.1 0 0.1 -0.1 12/25/2004 03:30:00 9.4 1.2 13.3 6.5 11.6 1 14.9 9.1 0.4 0 0.4 0.4 156 6 163 305 115 1 117 0 -0.1 0 0.1 -0.1 12/25/2004 03:40:00 9.7 1.2 13.7 6.8 11.7 0.8 14.9 9.5 0.4 0 0.4 0.4 158 6 160 305 116 0 116 0 -0.1 0 0.1 -0.1 12/25/2004 03:50:00 10 1.1 13.3 7.2 12.3 1.1 15.6 9.9 0.4 0 0.4 0.4 156 6 156 305 116 2 119 0 0 0 0.3 -0.1 12/25/2004 04:00:00 10.6 1.1 13.7 8 13.8 1.1 17.2 11.5 0.4 0 0.4 0.4 152 5 150 305 112 1 112 0 0 0 0.6 0.1 12/25/2004 04:10:00 11.1 1.2 15.3 8.4 14.2 1.2 17.9 11.1 0.4 0 0.4 0.4 152 5 160 305 110 1 111 0 0 0.1 0.6 0.1 12/25/2004 04:20:00 11.1 1.1 14.9 7.6 14.1 1.3 17.6 9.9 0.4 0 0.4 0.4 151 5 154 305 109 1 109 0 0.1 0.1 0.6 0.1 12/25/2004 04:30:00 10.8 1.1 15.3 7.6 14.1 1.1 16.8 10.7 0.4 0 0.4 0.4 150 5 145 305 105 3 108 0 0.1 0.1 0.6 0.1 12/25/2004 04:40:00 10.2 1 15.3 7.6 13.7 1.2 16.4 10.3 0.4 0 0.4 0.4 149 5 141 305 106 1 106 0 0.1 0.1 0.6 0.1 12/25/2004 04:50:00 9.7 1.1 12.6 6.1 13.2 1.1 16.1 9.9 0.4 0 0.4 0.4 149 5 150 305 108 1 106 0 0.1 0.1 0.6 0.1 12/25/2004 05:00:00 9.4 1.3 13.7 6.5 11.9 1.1 14.9 8.8 0.4 0 0.4 0.4 146 5 140 305 108 0 108 0 0.1 0 0.6 0.1 12/25/2004 05:10:00 9.4 1.2 14.1 6.8 12 1.1 15.3 9.1 0.4 0 0.4 0.4 146 5 141 305 112 3 112 0 0.1 0 0.6 0.1 12/25/2004 05:20:00 9.7 1 13 7.2 12.9 1.1 16.4 9.5 0.4 0 0.4 0.4 147 5 158 305 123 1 123 0 0.2 0 0.6 0.1 12/25/2004 05:30:00 9.7 1 13 7.6 12.8 1.1 15.6 9.1 0.4 0 0.4 0.4 147 5 145 305 121 2 120 0 0.2 0 0.6 0.1 12/25/2004 05:40:00 10.8 1.2 14.5 8 14 1.2 16.8 9.9 0.4 0 0.4 0.4 148 5 144 305 120 1 122 0 0.3 0 0.6 0.1 12/25/2004 05:50:00 11.3 1.1 14.9 8.8 14.5 1.1 17.6 11.5 0.4 0 0.4 0.4 151 5 150 305 122 1 120 0 0.4 0 0.8 0.3 12/25/2004 06:00:00 12.4 1.4 16.8 8.8 15.3 1.2 18.3 11.5 0.4 0 0.4 0.4 154 5 162 305 121 2 121 0 0.5 0 0.8 0.3 12/25/2004 06:10:00 12.8 1.3 16.8 9.5 16 1.2 18.3 12.6 0.4 0 0.4 0.4 154 4 160 305 120 1 121 0 0.5 0 0.8 0.6 12/25/2004 06:20:00 13.2 1.5 17.9 8.8 16.5 1.2 19.9 12.2 0.4 0 0.4 0.4 151 4 151 305 118 1 119 0 0.3 0.2 1 0.1 12/25/2004 06:30:00 12.8 1.5 18.7 9.5 17 1.3 21 11.8 0.4 0 0.4 0.4 151 4 155 305 118 1 117 0 0.4 0.1 0.8 0.1 12/25/2004 06:40:00 13.4 1.6 17.9 9.5 17.7 1.3 21.8 14.1 0.4 0 0.4 0.4 158 5 154 305 117 1 117 0 0.6 0 1 0.6 12/25/2004 06:50:00 14.9 1.5 19.1 10.7 18.5 1.3 21.8 14.9 0.4 0 0.4 0.4 167 5 173 305 119 1 119 0 0.6 0 1 0.6 12/25/2004 07:00:00 15.1 1.7 19.5 11.1 18 1.4 20.6 13.3 0.4 0 0.4 0.4 168 5 176 305 121 1 121 0 0.6 0.1 1 0.6 12/25/2004 07:10:00 15.6 1.5 19.9 11.5 19.1 1.3 22.6 15.6 0.4 0 0.4 0.4 168 5 174 305 122 1 122 0 0.7 0 1 0.6 12/25/2004 07:20:00 15.8 1.4 19.9 11.8 19.2 1.3 22.9 14.9 0.4 0 0.4 0.4 168 4 170 305 121 1 121 0 0.7 0 1 0.6 12/25/2004 07:30:00 16 1.5 21 11.8 19 1.3 23.7 15.6 0.4 0 0.4 0.4 169 5 169 305 122 1 123 0 0.7 0 0.8 0.6 12/25/2004 07:40:00 16.2 1.5 20.2 12.2 19 1.5 22.1 13 0.4 0 0.4 0.4 168 5 176 305 125 1 123 0 0.8 0 1.3 0.6 12/25/2004 07:50:00 16.5 1.5 20.2 13 19.4 1.3 23.3 15.3 0.4 0 0.4 0.4 168 5 169 305 121 2 119 0 0.8 0 1 0.6 12/25/2004 08:00:00 15.9 1.5 20.2 11.8 18.8 1.5 23.7 14.5 0.4 0 0.7 0.4 168 5 175 305 126 3 128 0 0.8 0 1.3 0.6 12/25/2004 08:10:00 16.1 1.6 20.2 11.8 19.2 1.3 22.9 15.3 0.4 0 0.4 0.4 167 4 169 305 125 1 125 0 0.8 0 1.3 0.6 12/25/2004 08:20:00 13.8 1.6 18.3 10.3 18.2 1.4 22.1 12.6 0.4 0 0.7 0.4 166 5 174 305 129 1 128 0 0.9 0 1.3 0.8 12/25/2004 08:30:00 13.7 1.6 19.9 10.3 19.1 1.8 24 13.7 0.4 0 0.4 0.4 167 5 186 305 137 4 140 0 1 0.1 1.5 0.8 12/25/2004 08:40:00 13.7 1.8 19.9 9.5 18.5 1.7 23.7 14.5 0.4 0 0.4 0.4 170 6 179 305 136 2 139 0 1.3 0.1 1.7 1.3 12/25/2004 08:50:00 13.7 2.1 21.4 9.1 17.2 1.5 21.4 13.7 0.4 0 0.4 0.4 173 6 181 305 139 2 141 0 1.2 0.1 1.5 1 12/25/2004 09:00:00 15.1 2.4 20.6 9.5 17.9 1.9 22.9 13 0.4 0 0.4 0.4 176 6 178 305 139 1 138 0 1.2 0 1.5 1 12/25/2004 09:10:00 16.1 2.1 22.1 10.3 18.3 1.6 22.1 14.5 0.4 0 0.4 0.4 177 5 181 305 138 1 137 0 1.1 0 1.5 1 12/25/2004 09:20:00 15.9 1.9 20.6 10.3 17.8 1.5 20.6 13.7 0.4 0 0.4 0.4 178 5 183 305 139 1 139 0 1.1 0 1.5 1 12/25/2004 09:30:00 15.9 2 20.6 11.5 18.4 1.6 22.6 14.9 0.4 0 0.4 0.4 178 5 186 305 140 0 139 0 1.1 0 1.5 1 12/25/2004 09:40:00 16.3 2.3 21.4 11.1 19.2 1.7 23.7 13.3 0.4 0 0.4 0.4 178 5 186 305 139 0 140 0 1.1 0.1 1.5 1 12/25/2004 09:50:00 17.4 2 22.6 12.2 18.7 1.6 22.6 14.9 0.4 0 0.4 0.4 180 5 181 305 140 0 140 0 1.1 0 1.5 1 12/25/2004 10:00:00 18.2 2 22.6 13 19 1.6 22.9 15.3 0.4 0 0.4 0.4 183 4 190 305 140 0 140 0 1 0 1.5 1 12/25/2004 10:10:00 19.4 2 25.2 13.7 19.5 2.1 25.2 14.9 0.4 0 0.4 0.4 186 4 189 305 140 0 140 0 1 0 1.5 0.8 12/25/2004 10:20:00 20.3 1.8 25.2 15.6 20.4 1.7 25.2 16.1 0.4 0 0.4 0.4 186 4 184 305 140 0 140 0 1 0 1.5 0.8 12/25/2004 10:30:00 20.9 1.7 25.6 16.1 20.4 1.7 24 14.5 0.4 0 0.4 0.4 189 4 192 305 141 0 141 0 0.9 0 1.5 0.8 12/25/2004 10:40:00 20.8 1.5 24 16.4 20 1.7 23.7 14.9 0.4 0 0.4 0.4 191 3 193 305 140 0 141 0 0.8 0.1 1.3 0.6 12/25/2004 10:50:00 21.2 1.5 26.8 17.2 20 1.5 25.2 15.3 0.4 0 0.4 0.4 194 4 201 305 140 0 140 0 0.6 0.1 1.3 0.6 12/25/2004 11:00:00 19.3 1.7 24 16.1 18.4 1.7 22.9 13.7 0.4 0 0.4 0.4 195 4 195 305 140 0 139 0 0.6 0.1 1 0.6 12/25/2004 11:10:00 19.6 1.8 23.7 14.9 18.6 2.1 23.3 13.3 0.4 0 0.7 0.4 195 4 196 305 139 0 139 0 0.5 0 1 0.3 12/25/2004 11:20:00 19.6 1.4 22.9 15.6 18.6 1.6 22.9 14.1 0.4 0 0.4 0.4 199 4 208 305 139 0 139 0 0.4 0 1 0.3 12/25/2004 11:30:00 20.2 1.5 23.7 16.4 19.4 1.7 24 13 0.4 0 0.4 0.4 201 4 199 305 139 0 138 0 0.3 0 0.8 0.1 12/25/2004 11:40:00 19.9 1.3 23.3 15.3 19.2 1.3 22.9 15.3 0.4 0 0.4 0.4 203 4 205 305 138 0 138 0 0.1 0 0.6 0.1 12/25/2004 11:50:00 20.6 1.5 24 16.4 19.8 1.5 23.3 15.6 0.4 0 0.4 0.4 204 3 206 305 139 0 139 0 0.1 0 0.3 0.1 12/25/2004 12:00:00 20.9 1.7 24.4 16.4 20.1 1.7 24 14.5 0.4 0 0.4 0.4 206 4 206 305 140 0 139 0 0.1 0.1 0.6 0.1 12/25/2004 12:10:00 20 1.6 24.4 14.5 18.9 1.7 22.9 13.7 0.4 0 0.4 0.4 208 4 207 305 140 0 140 0 0 0 0.6 0.1 12/25/2004 12:20:00 20.3 2.2 26 14.5 19.3 2 24.8 13.7 0.4 0 0.4 0.4 208 5 212 305 140 0 140 0 -0.1 0 0.3 -0.4 12/25/2004 12:30:00 19.4 1.7 24.4 15.3 18.3 2 23.3 13.7 0.4 0 0.4 0.4 207 4 209 305 140 0 140 0 -0.3 0 0.1 -0.4 12/25/2004 12:40:00 20.6 1.3 24.4 16.1 19.7 1.7 22.9 14.1 0.4 0 0.4 0.4 208 4 205 305 140 0 141 0 -0.3 0 0.1 -0.4 12/25/2004 12:50:00 19.8 1.7 24.4 15.3 18.3 1.9 23.3 13 0.4 0 0.4 0.4 211 6 210 305 140 0 140 0 -0.4 0 0.1 -0.6 12/25/2004 13:00:00 21.3 1.8 25.2 16.4 19.8 2.1 24.4 14.5 0.4 0 0.7 0.4 213 5 214 305 140 0 140 0 -0.4 0.1 0.1 -0.6 12/25/2004 13:10:00 20.5 1.8 24.4 14.9 19.3 2.1 24 14.1 0.4 0 0.4 0.4 213 5 217 305 140 0 140 0 -0.4 0.1 0.1 -0.4 12/25/2004 13:20:00 19.2 1.8 23.7 13.7 17.7 2.1 23.3 12.2 0.4 0 0.7 0.4 212 5 215 305 132 4 134 0 -0.5 0 0.1 -0.6 12/25/2004 13:30:00 18.3 2 22.6 12.6 16.7 2 21.4 10.7 0.4 0 0.4 0.4 212 5 215 305 124 1 126 0 -0.6 0 0.1 -0.6 12/25/2004 13:40:00 18.6 1.7 22.6 13.7 16.9 2.1 21.4 12.2 0.4 0 0.4 0.4 213 5 212 305 123 0 123 0 -0.7 0 -0.4 -0.6 12/25/2004 13:50:00 17.9 1.7 22.1 13.3 16.4 1.7 21.4 12.2 0.4 0 0.4 0.4 213 5 211 305 123 0 123 0 -0.7 0 -0.4 -0.8 12/25/2004 14:00:00 17.3 1.5 21.8 13.3 15.8 1.7 21.4 11.5 0.4 0 0.4 0.4 211 5 215 305 123 0 123 0 -0.7 0 -0.4 -0.8 12/25/2004 14:10:00 19.3 1.8 23.7 14.1 18.2 1.9 22.9 13.3 0.4 0 0.4 0.4 217 6 222 305 125 1 126 0 -0.6 0 -0.1 -0.6 12/25/2004 14:20:00 19.9 1.9 24.4 15.6 18.8 2.2 24.4 13.3 0.4 0 0.4 0.4 222 6 214 305 126 0 127 0 -0.5 0 0.1 -0.6 12/25/2004 14:30:00 18 2.5 23.3 11.8 16.8 2.5 24 10.7 0.4 0 0.4 0.4 225 6 232 305 128 0 127 0 -0.5 0 0.1 -0.6 12/25/2004 14:40:00 16.2 1.7 21 11.5 15 1.7 20.2 10.7 0.4 0 0.4 0.4 223 5 224 305 127 0 126 0 -0.6 0 0.1 -0.6 12/25/2004 14:50:00 17.2 1.5 20.6 13 16.3 1.5 20.2 11.8 0.4 0 0.4 0.4 219 5 215 305 126 0 125 0 -0.6 0 0.1 -0.6 12/25/2004 15:00:00 16.8 1.7 21.8 12.2 15.9 1.7 20.2 10.7 0.4 0 0.4 0.4 218 5 224 305 124 0 125 0 -0.6 0 0.1 -0.6 12/25/2004 15:10:00 15.3 1.2 18.3 12.2 14.2 1.5 17.6 9.5 0.4 0 0.4 0.4 213 5 216 305 125 0 125 0 -0.6 0 -0.1 -0.6 12/25/2004 15:20:00 15.7 1.2 19.1 11.1 14.8 1.4 19.1 11.1 0.4 0 0.4 0.4 217 5 214 305 124 0 124 0 -0.6 0 0.1 -0.6 12/25/2004 15:30:00 13.9 1.2 16.8 10.7 13 1.2 16.1 9.1 0.4 0 0.4 0.4 219 5 218 305 125 0 125 0 -0.6 0 -0.1 -0.6 12/25/2004 15:40:00 13.5 0.9 15.6 11.1 12.8 1 15.6 10.3 0.4 0 0.4 0.4 216 4 214 305 124 0 125 0 -0.6 0 -0.6 -0.6 12/25/2004 15:50:00 13.9 1.5 17.9 10.7 13 1.4 16.8 9.9 0.4 0 0.4 0.4 212 5 213 305 126 0 125 0 -0.5 0 -0.4 -0.6 12/25/2004 16:00:00 14.8 1.3 17.9 10.7 13.9 1.4 16.8 10.3 0.4 0 0.4 0.4 210 5 208 305 125 0 125 0 -0.5 0 0.1 -0.6 12/25/2004 16:10:00 15.3 1.4 18.7 11.5 14.3 1.6 18.3 9.9 0.4 0 0.4 0.4 211 5 216 305 126 0 127 0 -0.5 0 0.1 -0.6 12/25/2004 16:20:00 14.2 1.2 17.2 10.3 13.1 1.4 17.2 9.5 0.4 0 0.4 0.4 211 5 213 305 130 2 129 0 -0.6 0 -0.4 -0.6 12/25/2004 16:30:00 14.2 1.2 17.6 10.3 13.1 1.5 16.8 9.1 0.4 0 0.4 0.4 213 5 217 305 131 0 131 0 -0.6 0 -0.6 -0.6 12/25/2004 16:40:00 14.2 1.2 17.6 10.3 13.2 1.5 17.6 9.1 0.4 0 0.4 0.4 214 6 218 305 128 1 128 0 -0.5 0 -0.1 -0.6 12/25/2004 16:50:00 13.5 1.1 16.8 10.3 12.7 1.3 16.1 9.1 0.4 0 0.4 0.4 217 4 224 305 123 2 125 0 -0.5 0 -0.1 -0.6 12/25/2004 17:00:00 13.1 0.9 16.1 10.7 12.4 1 16.1 9.9 0.4 0 0.4 0.4 216 4 213 305 118 0 117 0 -0.5 0.1 0.1 -0.6 12/25/2004 17:10:00 12.7 1.3 16.8 9.1 11.7 1.4 15.6 8.8 0.4 0 0.4 0.4 222 5 225 305 117 0 117 0 -0.4 0.1 0.1 -0.6 12/25/2004 17:20:00 12.4 1.1 14.5 9.1 11.4 1.2 14.5 8.4 0.4 0 0.4 0.4 226 5 218 305 116 1 115 0 -0.4 0.1 0.1 -0.6 12/25/2004 17:30:00 12.2 1.1 15.3 9.1 11.2 1.2 14.9 8.4 0.4 0 0.4 0.4 225 5 230 305 114 0 115 0 -0.5 0 0.1 -0.6 12/25/2004 17:40:00 12.5 1.2 15.6 9.1 11.6 1.3 14.9 9.1 0.4 0 0.4 0.4 228 6 242 305 113 0 113 0 -0.5 0.1 0.1 -0.6 12/25/2004 17:50:00 12.3 1.5 16.8 8.8 11.4 1.5 16.4 8 0.4 0 0.4 0.4 227 5 232 305 113 0 113 0 -0.5 0 0.1 -0.6 12/25/2004 18:00:00 12.6 1.3 16.1 8.4 11.7 1.5 14.9 8.4 0.4 0 0.4 0.4 228 6 233 305 111 0 112 0 -0.6 0 0.1 -0.6 12/25/2004 18:10:00 12.2 1.2 16.8 9.1 11.4 1.3 15.6 8.4 0.4 0 0.4 0.4 228 5 227 305 110 0 111 0 -0.6 0 -0.1 -0.6 12/25/2004 18:20:00 11.2 1.1 13.7 8.4 10.4 1.3 13.7 7.2 0.4 0 0.4 0.4 227 5 232 305 110 1 110 0 -0.7 0 -0.4 -1.1 12/25/2004 18:30:00 10.6 0.9 12.6 8.4 9.6 1 12.2 6.5 0.4 0 0.4 0.4 223 5 224 305 108 1 107 0 -1 0.1 -0.4 -1.1 12/25/2004 18:40:00 10 0.8 11.8 7.2 9.1 0.9 11.5 7.2 0.4 0 0.4 0.4 223 5 223 305 106 1 107 0 -1.1 0 -0.6 -1.3 12/25/2004 18:50:00 10.3 0.8 12.6 8 9.6 1 11.8 7.2 0.4 0 0.4 0.4 220 5 221 305 102 1 101 0 -1.4 0 -0.8 -1.5 12/25/2004 19:00:00 11 0.6 13 8.8 10.4 0.7 12.2 7.6 0.4 0 0.4 0.4 215 4 213 305 100 0 100 0 -1.4 0 -1.1 -1.5 12/25/2004 19:10:00 10.6 0.9 13 8 9.8 1.1 13.3 7.2 0.4 0 0.4 0.4 213 4 213 305 100 1 100 0 -1.5 0.1 -1.1 -1.8 12/25/2004 19:20:00 9.3 0.9 11.5 6.8 8.5 1 11.1 6.1 0.4 0 0.4 0.4 212 5 204 305 99 1 97 0 -1.6 0 -1.1 -1.8 12/25/2004 19:30:00 10 0.9 12.2 8 9.6 0.9 11.8 7.2 0.4 0 0.4 0.4 207 3 203 305 96 1 95 0 -1.8 0 -1.1 -2 12/25/2004 19:40:00 11.1 0.7 13 9.1 10.8 0.8 12.6 8.8 0.4 0 0.4 0.4 204 3 205 305 95 0 96 0 -1.9 0.1 -1.3 -2 12/25/2004 19:50:00 10.4 0.6 12.2 8.8 10 0.6 11.8 8 0.4 0 0.4 0.4 202 3 204 305 94 0 94 0 -2.1 0 -1.8 -2.2 12/25/2004 20:00:00 9 0.7 11.1 7.6 8.7 0.7 10.7 6.8 0.4 0 0.4 0.4 203 3 201 305 96 1 95 0 -1.9 0 -1.3 -2 12/25/2004 20:10:00 9 0.4 10.3 8 8.8 0.5 10.3 7.2 0.4 0 0.4 0.4 201 3 201 305 97 0 97 0 -1.8 0 -1.3 -2 12/25/2004 20:20:00 9.2 0.5 11.1 8 8.8 0.6 10.3 6.5 0.4 0 0.4 0.4 197 3 202 305 98 0 97 0 -1.8 0 -1.3 -2 12/25/2004 20:30:00 10.1 0.8 11.8 7.6 9.8 0.8 11.8 7.2 0.4 0 0.4 0.4 201 4 202 305 100 1 101 0 -1.5 0.2 -0.8 -1.8 12/25/2004 20:40:00 7.8 0.5 9.1 6.5 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 201 4 205 305 101 0 102 0 -1.7 0 -1.1 -2 12/25/2004 20:50:00 7 0.4 8 5.7 6.8 0.5 8 5.3 0.4 0 0.4 0.4 204 3 206 305 100 0 100 0 -1.8 0 -1.3 -2 12/25/2004 21:00:00 6.7 0.5 8.4 5.3 6.5 0.6 8.4 4.6 0.4 0 0.4 0.4 206 4 204 305 99 0 99 0 -1.7 0 -1.3 -2 12/25/2004 21:10:00 6.5 0.5 8.4 4.9 6 0.6 7.6 3.8 0.4 0 0.4 0.4 209 4 208 305 99 0 99 0 -1.6 0 -1.1 -1.8 12/25/2004 21:20:00 7.3 0.7 9.1 5.7 7 0.6 8.8 4.9 0.4 0 0.4 0.4 206 4 205 305 100 0 100 0 -1.5 0 -1.1 -1.8 12/25/2004 21:30:00 8.7 0.7 11.1 7.2 8.4 0.8 11.1 6.5 0.4 0 0.4 0.4 202 3 201 305 101 0 101 0 -1.1 0.1 -0.8 -1.3 12/25/2004 21:40:00 9.2 0.6 10.7 7.2 8.9 0.7 10.7 6.8 0.4 0 0.4 0.4 200 4 201 305 102 0 102 0 -0.9 0 -0.4 -1.1 12/25/2004 21:50:00 9.3 0.6 11.1 7.6 9 0.7 10.7 6.8 0.4 0 0.4 0.4 198 3 197 305 102 0 102 0 -0.8 0 -0.4 -1.1 12/25/2004 22:00:00 9.7 0.7 11.8 8 9.4 0.8 11.8 6.8 0.4 0 0.4 0.4 198 4 198 305 102 0 102 0 -0.7 0 -0.4 -0.8 12/25/2004 22:10:00 9.8 0.5 11.5 8.4 9.4 0.7 11.5 6.8 0.4 0 0.4 0.4 197 3 198 305 101 0 101 0 -0.7 0 -0.1 -0.6 12/25/2004 22:20:00 10.4 0.8 13 8.4 10.1 0.9 12.2 8 0.4 0 0.4 0.4 198 3 197 305 101 0 101 0 -0.7 0 -0.1 -0.6 12/25/2004 22:30:00 11.8 0.8 14.1 9.9 11.4 0.9 14.1 9.1 0.4 0 0.4 0.4 201 4 207 305 101 0 101 0 -0.4 0.1 0.1 -0.6 12/25/2004 22:40:00 11.5 0.9 13.7 9.5 11.2 1 13.7 8.8 0.4 0 0.4 0.4 201 4 201 305 100 0 100 0 -0.4 0.1 0.1 -0.6 12/25/2004 22:50:00 11 0.8 13 9.1 10.7 0.8 12.6 8.8 0.4 0 0.4 0.4 201 4 197 305 99 1 100 0 -0.5 0 0.1 -0.6 12/25/2004 23:00:00 11.1 0.8 13.3 9.1 10.7 0.8 13 9.1 0.4 0 0.4 0.4 202 3 205 305 97 0 97 0 -0.6 0.1 0.1 -0.6 12/25/2004 23:10:00 11.1 0.7 13 9.1 10.7 0.8 13.3 8.4 0.4 0 0.4 0.4 202 3 201 305 99 1 98 0 -0.5 0.1 0.1 -0.6 12/25/2004 23:20:00 11.3 0.7 13.3 9.5 11 0.9 13.3 8.4 0.4 0 0.4 0.4 203 4 212 305 100 0 100 0 -0.4 0.1 0.1 -0.6 12/25/2004 23:30:00 11.3 0.8 13.7 9.5 10.9 0.8 13 9.1 0.4 0 0.4 0.4 206 4 208 305 101 0 101 0 -0.4 0.1 0.3 -0.4 12/25/2004 23:40:00 11.9 0.8 14.5 9.9 11.6 0.8 14.1 8.8 0.4 0 0.4 0.4 205 4 196 305 101 1 101 0 -0.4 0.1 0.1 -0.6 12/25/2004 23:50:00 11.4 0.9 14.1 8.8 11.1 0.9 13.7 9.1 0.4 0 0.4 0.4 205 3 202 305 98 1 97 0 -0.6 0 -0.1 -0.6 12/26/2004 00:00:00 11.8 0.9 14.5 9.1 11.5 0.9 13.7 8.8 0.4 0 0.4 0.4 206 4 213 305 95 1 96 0 -0.7 0 0.1 -1.1 12/26/2004 00:10:00 10.6 0.6 12.2 9.1 10.2 0.7 11.8 8 0.4 0 0.4 0.4 205 3 217 305 91 1 93 0 -1.1 0 -0.6 -1.3 12/26/2004 00:20:00 10.9 0.6 13 9.5 10.5 0.7 12.6 8.4 0.4 0 0.4 0.4 206 4 208 305 89 0 89 0 -1.2 0 -1.1 -1.3 12/26/2004 00:30:00 10.7 0.6 13 9.1 10.4 0.7 11.8 8.8 0.4 0 0.4 0.4 205 3 206 305 90 0 88 0 -1.1 0.1 -0.4 -1.3 12/26/2004 00:40:00 10.4 0.7 12.2 8.8 10.1 0.8 12.2 8 0.4 0 0.4 0.4 207 3 203 305 92 0 91 0 -0.9 0 -0.6 -1.1 12/26/2004 00:50:00 9.8 0.5 11.1 8.8 9.5 0.6 11.1 8 0.4 0 0.4 0.4 206 3 204 305 92 0 92 0 -0.8 0 -0.1 -1.1 12/26/2004 01:00:00 9.5 0.6 11.5 8.4 9.3 0.6 11.1 7.6 0.4 0 0.4 0.4 204 3 207 305 92 0 93 0 -0.7 0 -0.4 -0.8 12/26/2004 01:10:00 8.9 0.7 10.7 6.8 8.6 0.7 9.9 6.5 0.4 0 0.4 0.4 203 3 203 305 92 0 92 0 -0.8 0 -0.4 -0.8 12/26/2004 01:20:00 10.4 0.7 12.6 8.4 10.1 0.8 12.2 8.4 0.4 0 0.4 0.4 202 4 197 305 91 0 91 0 -0.8 0 -0.4 -0.8 12/26/2004 01:30:00 10.2 0.6 12.2 8.8 10 0.6 12.2 8 0.4 0 0.4 0.4 201 3 204 305 91 0 92 0 -0.7 0 -0.4 -0.8 12/26/2004 01:40:00 9.6 0.6 11.5 8 9.5 0.7 11.5 7.6 0.4 0 0.4 0.4 203 4 202 305 92 1 91 0 -0.7 0 -0.4 -0.8 12/26/2004 01:50:00 9.7 0.6 11.1 8 9.5 0.7 11.5 7.6 0.4 0 0.4 0.4 205 4 206 305 93 0 92 0 -0.7 0 -0.1 -0.8 12/26/2004 02:00:00 9.5 0.7 11.1 7.6 9.1 0.7 11.1 6.8 0.4 0 0.4 0.4 205 4 207 305 93 0 93 0 -0.6 0 -0.1 -0.6 12/26/2004 02:10:00 9.4 0.6 11.1 7.6 9.1 0.6 11.1 6.8 0.4 0 0.4 0.4 205 3 203 305 93 0 94 0 -0.5 0 0.1 -0.6 12/26/2004 02:20:00 9.4 0.6 11.5 8 9 0.7 11.1 7.2 0.4 0 0.4 0.4 207 3 208 305 94 0 95 0 -0.5 0.1 0.1 -0.6 12/26/2004 02:30:00 9.2 0.8 11.5 6.8 8.9 0.9 12.2 6.5 0.4 0 0.4 0.4 208 4 204 305 96 0 95 0 -0.4 0.1 0.1 -0.6 12/26/2004 02:40:00 8.8 0.6 10.3 7.2 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 208 4 207 305 96 0 95 0 -0.5 0 0.1 -0.6 12/26/2004 02:50:00 9.5 0.8 11.1 6.8 8.9 1 11.5 6.1 0.4 0 0.4 0.4 210 5 207 305 96 0 96 0 -0.5 0 0.1 -0.6 12/26/2004 03:00:00 9.5 0.6 11.1 7.2 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 205 4 212 305 97 0 96 0 -0.5 0.1 0.1 -0.6 12/26/2004 03:10:00 9.5 0.6 11.1 8 9.2 0.6 10.7 7.2 0.4 0 0.4 0.4 205 4 207 305 97 0 97 0 -0.5 0.1 0.1 -0.6 12/26/2004 03:20:00 9.4 0.6 11.1 8 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 206 3 205 305 96 0 96 0 -0.5 0.1 0.1 -0.6 12/26/2004 03:30:00 9.5 0.7 11.5 7.6 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 204 4 211 305 96 0 95 0 -0.5 0.1 0.1 -0.6 12/26/2004 03:40:00 10.6 0.6 12.2 8.4 10.2 0.8 12.2 7.6 0.4 0 0.4 0.4 207 4 203 305 95 0 95 0 -0.5 0.1 0.1 -0.6 12/26/2004 03:50:00 10.5 0.6 12.2 9.1 10.1 0.7 11.8 7.2 0.4 0 0.4 0.4 208 3 208 305 95 1 95 0 -0.5 0 0.1 -0.6 12/26/2004 04:00:00 10.1 0.9 12.2 7.2 9.3 1 12.2 6.1 0.4 0 0.4 0.4 211 5 213 305 95 0 95 0 -0.5 0 0.1 -0.6 12/26/2004 04:10:00 9.3 0.9 11.5 6.8 8.7 1 11.1 5.7 0.4 0 0.4 0.4 213 4 213 305 94 0 95 0 -0.6 0 0.1 -0.6 12/26/2004 04:20:00 9.4 0.9 12.2 6.8 8.9 1.1 12.2 6.1 0.4 0 0.4 0.4 208 5 212 305 93 0 93 0 -0.6 0 -0.4 -0.6 12/26/2004 04:30:00 10.1 0.7 12.2 8.4 9.6 0.8 11.5 7.6 0.4 0 0.4 0.4 208 3 208 305 93 0 93 0 -0.7 0 -0.4 -0.8 12/26/2004 04:40:00 9.5 0.7 11.8 8 8.9 0.9 11.1 6.1 0.4 0 0.4 0.4 210 5 211 305 92 0 92 0 -0.8 0 -0.4 -1.1 12/26/2004 04:50:00 10.5 0.8 12.2 7.6 9.8 1 12.2 6.5 0.4 0 0.4 0.4 210 5 213 305 92 0 91 0 -0.7 0 -0.4 -0.8 12/26/2004 05:00:00 10.5 0.6 12.6 9.1 10 0.7 11.8 7.6 0.4 0 0.4 0.4 206 4 210 305 91 0 92 0 -0.8 0 -0.4 -1.1 12/26/2004 05:10:00 9.8 0.6 11.5 7.6 9.5 0.6 11.1 7.6 0.4 0 0.4 0.4 207 3 205 305 91 0 91 0 -0.8 0 -0.4 -1.1 12/26/2004 05:20:00 8.9 0.6 10.7 7.2 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 207 3 202 305 90 0 91 0 -1 0.1 -0.4 -1.1 12/26/2004 05:30:00 9.5 0.6 11.1 8 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 205 3 210 305 91 0 91 0 -1 0.1 -0.4 -1.1 12/26/2004 05:40:00 9.1 0.6 11.1 7.2 8.8 0.7 10.7 6.5 0.4 0 0.4 0.4 207 3 209 305 91 0 91 0 -0.9 0 -0.4 -1.1 12/26/2004 05:50:00 8.5 0.6 10.3 6.5 8.2 0.7 9.9 6.1 0.4 0 0.4 0.4 208 4 208 305 91 0 92 0 -0.9 0.1 -0.4 -1.1 12/26/2004 06:00:00 8 0.5 9.5 6.8 7.8 0.5 9.5 6.1 0.4 0 0.4 0.4 206 4 208 305 91 0 91 0 -1 0.1 -0.4 -1.1 12/26/2004 06:10:00 7.9 0.4 9.1 6.8 7.8 0.4 8.8 6.5 0.4 0 0.4 0.4 203 3 208 305 90 0 90 0 -1.2 0.1 -0.6 -1.5 12/26/2004 06:20:00 8 0.5 9.1 6.8 7.6 0.5 9.1 5.7 0.4 0 0.4 0.4 200 3 205 305 91 0 91 0 -1.5 0.1 -1.1 -1.8 12/26/2004 06:30:00 7.7 0.4 9.1 6.8 7.5 0.4 8.4 6.5 0.4 0 0.4 0.4 198 3 199 305 91 0 91 0 -1.6 0.1 -1.1 -1.8 12/26/2004 06:40:00 7.8 0.5 9.5 6.5 7.5 0.5 9.1 6.1 0.4 0 0.4 0.4 204 4 203 305 91 0 91 0 -1.3 0 -0.6 -1.5 12/26/2004 06:50:00 7.5 0.4 8.8 6.5 7.3 0.5 8.8 6.1 0.4 0 0.4 0.4 203 4 200 305 91 0 91 0 -1.1 0 -0.6 -1.3 12/26/2004 07:00:00 7.5 0.4 8.8 6.5 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 196 3 201 305 90 0 91 0 -1.2 0 -0.6 -1.3 12/26/2004 07:10:00 7.5 0.4 9.1 6.5 7.3 0.5 8.4 5.3 0.4 0 0.4 0.4 197 4 194 305 90 0 90 0 -1.3 0 -0.6 -1.3 12/26/2004 07:20:00 7.6 0.6 9.1 6.5 7.3 0.6 9.1 6.1 0.4 0 0.4 0.4 199 4 203 305 90 0 90 0 -1.4 0.1 -0.6 -1.5 12/26/2004 07:30:00 8 0.5 9.1 6.8 7.7 0.5 9.1 6.5 0.4 0 0.4 0.4 199 3 198 305 89 0 90 0 -1.5 0.1 -0.8 -1.8 12/26/2004 07:40:00 7.5 0.5 8.8 6.5 7.4 0.5 8.8 6.1 0.4 0 0.4 0.4 201 4 200 305 89 0 90 0 -1.5 0.1 -0.8 -1.8 12/26/2004 07:50:00 8.2 0.5 9.9 6.8 8.1 0.6 9.9 6.5 0.4 0 0.4 0.4 203 4 206 305 89 0 89 0 -1.5 0.1 -1.1 -1.8 12/26/2004 08:00:00 8.1 0.5 9.5 6.5 7.9 0.6 9.1 6.5 0.4 0 0.4 0.4 201 4 198 305 88 0 88 0 -1.6 0 -1.1 -1.8 12/26/2004 08:10:00 8.1 0.5 9.9 6.8 8 0.5 9.5 6.5 0.4 0 0.4 0.4 198 4 205 305 88 0 88 0 -1.7 0 -1.3 -1.8 12/26/2004 08:20:00 7.4 0.6 8.8 6.1 7.2 0.6 9.1 5.7 0.4 0 0.4 0.4 201 4 203 305 88 0 88 0 -1.7 0 -1.3 -1.8 12/26/2004 08:30:00 7.4 0.6 9.5 6.1 7.2 0.6 9.1 5.7 0.4 0 0.4 0.4 203 4 209 305 88 0 88 0 -1.7 0 -1.3 -2 12/26/2004 08:40:00 6.5 0.4 7.6 5.3 6.4 0.5 8 4.6 0.4 0 0.4 0.4 201 4 205 305 88 0 88 0 -1.8 0 -1.5 -2 12/26/2004 08:50:00 6.3 0.4 7.6 4.9 6.2 0.4 7.6 4.9 0.4 0 0.4 0.4 198 4 205 305 87 0 87 0 -1.9 0 -1.5 -2 12/26/2004 09:00:00 6 0.4 6.8 4.6 5.9 0.5 7.2 4.2 0.4 0 0.4 0.4 195 3 194 305 87 0 87 0 -2 0.1 -1.8 -2.2 12/26/2004 09:10:00 6.3 0.4 7.6 5.3 6.1 0.4 7.6 4.9 0.4 0 0.4 0.4 196 3 207 305 86 0 86 0 -2 0.1 -1.5 -2.2 12/26/2004 09:20:00 6.3 0.4 8 5.3 6.1 0.4 6.8 4.9 0.4 0 0.4 0.4 197 4 206 305 85 0 86 0 -2 0.1 -1.5 -2.2 12/26/2004 09:30:00 6 0.4 7.2 4.6 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 193 5 192 305 84 0 85 0 -2 0.1 -1.5 -2.2 12/26/2004 09:40:00 6.2 0.4 7.2 4.6 6.1 0.5 7.2 3.8 0.4 0 0.4 0.4 190 4 192 305 84 0 84 0 -2 0.1 -1.5 -2 12/26/2004 09:50:00 5.9 0.4 7.2 4.9 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 189 4 187 305 84 0 84 0 -1.9 0 -1.3 -2 12/26/2004 10:00:00 6.2 0.5 7.6 4.9 6 0.6 7.2 4.6 0.4 0 0.4 0.4 192 4 192 305 84 0 84 0 -1.8 0 -1.3 -1.8 12/26/2004 10:10:00 6.2 0.4 7.6 5.3 6.1 0.5 7.2 4.6 0.4 0 0.4 0.4 194 4 194 305 84 0 84 0 -1.7 0 -1.3 -1.8 12/26/2004 10:20:00 6.5 0.4 8 5.3 6.3 0.5 7.6 4.9 0.4 0 0.4 0.4 194 4 194 305 83 0 83 0 -1.8 0 -1.3 -1.8 12/26/2004 10:30:00 6.4 0.4 7.6 5.3 6.2 0.5 7.2 4.9 0.4 0 0.4 0.4 194 4 198 305 83 0 83 0 -1.8 0 -1.3 -2 12/26/2004 10:40:00 6.4 0.4 7.6 5.7 6.3 0.4 7.6 4.9 0.4 0 0.4 0.4 194 3 200 305 83 0 83 0 -1.8 0 -1.3 -2 12/26/2004 10:50:00 6 0.4 7.6 4.9 5.9 0.4 7.2 4.6 0.4 0 0.4 0.4 193 4 194 305 82 0 82 0 -1.8 0 -1.3 -2 12/26/2004 11:00:00 5.7 0.4 6.8 4.6 5.6 0.4 6.8 4.6 0.4 0 0.4 0.4 192 4 190 305 82 0 82 0 -1.8 0 -1.3 -2 12/26/2004 11:10:00 5.2 0.5 6.5 3.4 5.2 0.6 6.5 3.8 0.4 0 0.4 0.4 189 5 192 305 81 0 82 0 -1.8 0 -1.3 -2 12/26/2004 11:20:00 5.9 0.4 6.8 4.6 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 187 4 186 305 81 0 81 0 -1.8 0 -1.3 -2 12/26/2004 11:30:00 6.1 0.4 7.2 5.3 6.4 0.4 7.6 4.6 0.4 0 0.4 0.4 187 4 190 305 81 0 81 0 -1.8 0 -1.3 -2 12/26/2004 11:40:00 5.7 0.5 6.8 4.2 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 187 4 195 305 80 0 80 0 -1.7 0 -1.3 -1.8 12/26/2004 11:50:00 5.5 0.5 7.2 3.4 5.5 0.6 6.5 3.8 0.4 0 0.4 0.4 189 5 196 305 80 0 80 0 -1.7 0 -1.3 -1.8 12/26/2004 12:00:00 6 0.4 7.6 4.9 6.3 0.4 7.2 4.6 0.4 0 0.4 0.4 188 3 189 305 80 0 80 0 -1.7 0 -1.1 -1.8 12/26/2004 12:10:00 6.1 0.3 6.8 5.3 6.4 0.3 7.2 5.3 0.4 0 0.4 0.4 188 3 190 305 80 0 80 0 -1.7 0 -1.1 -1.8 12/26/2004 12:20:00 5.7 0.4 6.5 4.9 5.7 0.4 6.8 4.6 0.4 0 0.4 0.4 194 4 186 305 79 0 79 0 -1.7 0 -1.1 -1.8 12/26/2004 12:30:00 5.5 0.4 6.8 4.6 5.5 0.4 6.5 4.2 0.4 0 0.4 0.4 194 4 191 305 79 0 79 0 -1.8 0 -1.3 -2 12/26/2004 12:40:00 5.4 0.4 6.1 4.2 5.5 0.5 6.8 3.8 0.4 0 0.4 0.4 190 4 196 305 79 0 78 0 -1.9 0.1 -1.3 -2 12/26/2004 12:50:00 5.4 0.5 6.8 3.8 5.5 0.5 6.8 3.8 0.4 0 0.4 0.4 189 5 200 305 78 0 78 0 -2 0.1 -1.5 -2 12/26/2004 13:00:00 5.4 0.4 6.5 4.6 5.4 0.4 6.5 4.2 0.4 0 0.4 0.4 191 4 196 305 78 0 78 0 -1.8 0 -1.3 -2 12/26/2004 13:10:00 5.3 0.4 6.1 4.2 5.8 0.4 6.8 4.2 0.4 0 0.4 0.4 186 4 188 305 78 0 78 0 -1.8 0 -1.3 -2 12/26/2004 13:20:00 5.1 0.4 6.5 4.2 5.7 0.4 6.5 4.6 0.4 0 0.4 0.4 186 5 188 305 78 0 78 0 -1.8 0 -1.3 -2 12/26/2004 13:30:00 5 0.6 6.5 3.4 5.4 0.7 6.8 3.4 0.4 0 0.4 0.4 186 6 179 305 78 0 78 0 -2 0.1 -1.5 -2 12/26/2004 13:40:00 5.5 0.6 7.2 4.2 5.9 0.5 7.6 4.2 0.4 0 0.4 0.4 187 6 182 305 78 0 78 0 -2 0.1 -1.8 -2.2 12/26/2004 13:50:00 5.4 0.7 7.6 3.4 6 0.6 7.6 4.2 0.4 0 0.4 0.4 186 6 202 305 78 0 78 0 -2 0.1 -1.8 -2.2 12/26/2004 14:00:00 6.1 0.6 7.6 4.6 6.4 0.5 8.4 4.9 0.4 0 0.4 0.4 187 5 191 305 77 0 77 0 -2 0 -1.8 -2.2 12/26/2004 14:10:00 6.3 0.4 7.2 5.3 6.6 0.4 7.6 5.3 0.4 0 0.4 0.4 188 3 189 305 77 0 77 0 -2 0 -1.8 -2.2 12/26/2004 14:20:00 6.6 0.4 7.6 5.3 6.9 0.4 8 5.7 0.4 0 0.4 0.4 190 4 191 305 77 0 77 0 -2 0.1 -1.8 -2.2 12/26/2004 14:30:00 6.3 0.5 7.6 5.3 6.6 0.5 8 5.3 0.4 0 0.4 0.4 189 4 192 305 77 0 77 0 -2 0 -1.5 -2.2 12/26/2004 14:40:00 6.1 0.6 7.2 4.2 6.4 0.6 7.6 4.6 0.4 0 0.4 0.4 188 3 188 305 77 0 77 0 -2 0 -1.3 -2 12/26/2004 14:50:00 5.3 0.8 7.2 3 5.8 0.7 7.6 4.2 0.4 0 0.4 0.4 184 4 189 305 77 0 77 0 -2 0.1 -1.5 -2.2 12/26/2004 15:00:00 4.8 0.5 6.5 3.8 4.9 0.5 6.5 3 0.4 0 0.4 0.4 191 5 186 305 77 0 77 0 -2.1 0.1 -1.8 -2.2 12/26/2004 15:10:00 4.9 0.4 5.7 3.8 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 192 4 198 305 76 0 77 0 -2.2 0 -1.8 -2.2 12/26/2004 15:20:00 4.6 0.4 5.3 3.8 4.8 0.3 5.7 3.8 0.4 0 0.4 0.4 189 3 189 305 76 0 76 0 -2.1 0.1 -1.5 -2.2 12/26/2004 15:30:00 4.6 0.3 5.3 3.8 4.5 0.4 5.3 3 0.4 0 0.4 0.4 192 3 193 305 76 0 76 0 -2.3 0 -1.8 -2.4 12/26/2004 15:40:00 4.9 0.4 6.1 3.8 5 0.5 6.1 3.4 0.4 0 0.4 0.4 191 5 190 305 75 0 76 0 -2.2 0.1 -1.8 -2.4 12/26/2004 15:50:00 5 0.5 6.1 3.8 5 0.5 6.1 3.4 0.4 0 0.4 0.4 193 5 198 305 75 0 75 0 -2.2 0 -1.8 -2.2 12/26/2004 16:00:00 5.2 0.4 6.5 4.2 5 0.4 6.1 3.4 0.4 0 0.4 0.4 199 4 197 305 75 0 74 0 -2.2 0 -1.8 -2.4 12/26/2004 16:10:00 5 0.3 5.7 4.2 4.9 0.4 5.7 3.8 0.4 0 0.4 0.4 200 3 203 305 75 0 75 0 -2.3 0 -2 -2.4 12/26/2004 16:20:00 4.9 0.3 5.7 4.2 4.8 0.3 5.7 3.8 0.4 0 0.4 0.4 196 4 198 305 75 0 75 0 -2.3 0 -2 -2.4 12/26/2004 16:30:00 4.8 0.4 5.7 3.4 4.7 0.4 5.7 3.4 0.4 0 0.4 0.4 191 5 202 305 74 0 74 0 -2.3 0 -1.8 -2.4 12/26/2004 16:40:00 4.8 0.4 6.1 3.4 4.8 0.5 5.7 3.4 0.4 0 0.4 0.4 192 5 194 305 74 0 74 0 -2.2 0 -1.8 -2.4 12/26/2004 16:50:00 4.6 0.4 5.7 3.8 4.6 0.3 5.7 3.4 0.4 0 0.4 0.4 196 5 200 305 74 0 74 0 -2.2 0 -1.8 -2.4 12/26/2004 17:00:00 4.9 0.4 6.1 3.8 4.9 0.4 6.1 3.8 0.4 0 0.4 0.4 196 4 196 305 74 0 74 0 -2.3 0 -1.8 -2.4 12/26/2004 17:10:00 4.7 0.4 5.7 3 4.6 0.5 6.1 3 0.4 0 0.4 0.4 192 5 191 305 74 0 74 0 -2.5 0 -2.4 -2.7 12/26/2004 17:20:00 4.5 0.5 5.7 3.4 4.4 0.5 5.7 3 0.4 0 0.4 0.4 193 7 205 305 74 0 74 0 -2.6 0 -2.4 -2.7 12/26/2004 17:30:00 4.3 0.4 5.3 3 4.3 0.4 5.7 3 0.4 0 0.4 0.4 192 8 190 305 74 0 74 0 -2.5 0 -2.4 -2.7 12/26/2004 17:40:00 4.9 0.7 6.1 3.4 5.3 0.6 6.8 3 0.4 0 0.4 0.4 188 7 184 305 74 0 74 0 -2.4 0 -2 -2.7 12/26/2004 17:50:00 5.4 0.6 6.8 3.4 5.7 0.6 7.6 4.2 0.4 0 0.4 0.4 188 7 201 305 74 0 74 0 -2.3 0 -2 -2.4 12/26/2004 18:00:00 5 0.6 6.5 3 5.4 0.5 6.8 3.8 0.4 0 0.4 0.4 188 7 188 305 74 0 74 0 -2.3 0 -1.8 -2.4 12/26/2004 18:10:00 5.4 0.6 7.2 3.4 5.7 0.6 7.6 4.6 0.4 0 0.4 0.4 190 6 198 305 74 0 74 0 -2.3 0 -2 -2.4 12/26/2004 18:20:00 4.7 0.6 6.1 3.4 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 188 6 192 305 74 0 74 0 -2.2 0 -1.8 -2.4 12/26/2004 18:30:00 4.8 0.5 5.7 2.6 5 0.5 6.5 3.8 0.4 0 0.4 0.4 188 5 189 305 74 0 74 0 -2.3 0 -2 -2.4 12/26/2004 18:40:00 4.7 0.4 5.7 3.4 4.8 0.4 5.7 3.4 0.4 0 0.4 0.4 188 4 186 305 74 0 74 0 -2.4 0 -2 -2.7 12/26/2004 18:50:00 4.4 0.5 5.7 3 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 190 5 194 305 74 0 74 0 -2.4 0 -2 -2.4 12/26/2004 19:00:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3 0.4 0 0.4 0.4 192 5 192 305 73 0 73 0 -2.4 0 -2 -2.4 12/26/2004 19:10:00 4.4 0.3 5.3 3.4 4.3 0.3 5.3 3.4 0.4 0 0.4 0.4 199 4 202 305 73 0 73 0 -2.4 0 -2 -2.7 12/26/2004 19:20:00 4.5 0.3 5.7 3.8 4.5 0.4 5.3 3.4 0.4 0 0.4 0.4 202 4 199 305 73 0 73 0 -2.4 0 -1.8 -2.7 12/26/2004 19:30:00 4.6 0.4 5.7 3.4 4.5 0.4 5.7 3 0.4 0 0.4 0.4 201 4 207 305 73 0 73 0 -2.6 0.1 -2 -2.7 12/26/2004 19:40:00 4.2 0.3 4.9 3.4 4.2 0.4 4.9 3 0.4 0 0.4 0.4 197 5 215 305 73 0 73 0 -2.7 0 -2.2 -2.7 12/26/2004 19:50:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3 0.4 0 0.4 0.4 198 5 203 305 73 0 73 0 -2.8 0 -2.2 -2.7 12/26/2004 20:00:00 4.1 0.4 4.9 3 4.1 0.4 4.9 3 0.4 0 0.4 0.4 204 3 206 305 73 0 73 0 -2.8 0 -2.2 -2.7 12/26/2004 20:10:00 4.7 0.5 6.1 3.8 4.6 0.5 5.7 3.4 0.4 0 0.4 0.4 206 5 214 305 73 0 73 0 -2.7 0 -2.2 -2.7 12/26/2004 20:20:00 4.4 0.4 5.3 3.4 4.3 0.4 5.7 3.4 0.4 0 0.4 0.4 203 4 202 305 73 0 73 0 -2.8 0 -2.4 -3.1 12/26/2004 20:30:00 4.5 0.4 5.7 3.4 4.4 0.4 5.3 3.4 0.4 0 0.4 0.4 205 5 219 305 74 0 73 0 -2.9 0 -2.4 -3.1 12/26/2004 20:40:00 4.4 0.4 5.7 3.4 4.3 0.4 5.3 3.4 0.4 0 0.4 0.4 204 6 223 305 73 0 73 0 -3 0 -2.4 -3.1 12/26/2004 20:50:00 4.5 0.4 5.3 3.4 4.4 0.5 5.3 3 0.4 0 0.4 0.4 198 3 200 305 73 0 73 0 -3.1 0.1 -2.7 -3.3 12/26/2004 21:00:00 4.4 0.4 5.3 3.4 4.3 0.4 5.3 3.4 0.4 0 0.4 0.4 201 3 200 305 73 0 73 0 -3.2 0 -3.1 -3.3 12/26/2004 21:10:00 4 0.3 4.9 3.4 4 0.3 4.9 3 0.4 0 0.4 0.4 201 4 205 305 73 0 72 0 -3.2 0 -2.9 -3.3 12/26/2004 21:20:00 4 0.3 4.9 3.4 3.9 0.4 4.6 3 0.4 0 0.4 0.4 197 5 203 305 73 0 73 0 -3.2 0 -2.7 -3.3 12/26/2004 21:30:00 4.1 0.4 4.9 2.6 4.1 0.4 4.9 2.6 0.4 0 0.4 0.4 194 5 186 305 73 0 72 0 -3.2 0 -3.1 -3.3 12/26/2004 21:40:00 3.7 0.4 4.6 2.6 3.7 0.4 4.6 2.3 0.4 0 0.4 0.4 195 5 199 305 73 0 73 0 -3.2 0 -2.7 -3.3 12/26/2004 21:50:00 3.8 0.5 5.3 2.6 3.8 0.5 5.7 2.6 0.4 0 0.4 0.4 193 6 194 305 74 0 74 0 -3.2 0 -2.7 -3.3 12/26/2004 22:00:00 4 0.5 5.3 2.3 4.2 0.4 5.3 3 0.4 0 0.4 0.4 186 6 188 305 74 0 74 0 -3.2 0 -2.7 -3.3 12/26/2004 22:10:00 3.9 0.5 5.3 1.9 4 0.6 5.3 2.3 0.4 0 0.4 0.4 190 7 190 305 74 0 74 0 -3.1 0 -2.7 -3.1 12/26/2004 22:20:00 3.8 0.6 5.7 1.9 3.9 0.6 5.7 2.3 0.4 0 0.4 0.4 190 7 194 305 74 0 74 0 -3 0 -2.4 -3.1 12/26/2004 22:30:00 3.9 0.7 6.1 2.3 4.1 0.7 6.1 2.3 0.4 0 0.4 0.4 189 7 187 305 74 0 74 0 -3 0 -2.7 -3.1 12/26/2004 22:40:00 4.7 0.6 6.5 2.3 4.9 0.5 6.5 3.8 0.4 0 0.4 0.4 186 5 194 305 74 0 74 0 -3.1 0 -2.4 -3.3 12/26/2004 22:50:00 4.2 0.4 5.3 2.3 4.3 0.4 4.9 3 0.4 0 0.4 0.4 187 4 191 305 74 0 74 0 -3.2 0 -2.7 -3.3 12/26/2004 23:00:00 4 0.5 5.3 3 3.9 0.5 4.9 3 0.4 0 0.4 0.4 194 5 194 305 74 0 74 0 -3.2 0 -2.9 -3.3 12/26/2004 23:10:00 3.9 0.6 5.3 2.6 4 0.6 5.3 2.3 0.4 0 0.4 0.4 189 4 196 305 74 0 74 0 -3.2 0 -2.7 -3.3 12/26/2004 23:20:00 3.4 0.7 4.6 1.1 3.6 0.5 4.6 2.3 0.4 0 0.4 0.4 185 6 192 305 74 0 74 0 -3.3 0 -2.7 -3.3 12/26/2004 23:30:00 3.5 0.5 4.9 1.9 3.8 0.5 4.9 1.9 0.4 0 0.4 0.4 190 9 191 305 74 0 74 0 -3.2 0 -2.7 -3.3 12/26/2004 23:40:00 4.3 0.9 6.1 1.9 4.6 0.6 6.1 3.4 0.4 0 0.4 0.4 187 8 197 305 74 0 74 0 -3.2 0.1 -2.7 -3.3 12/26/2004 23:50:00 3.5 0.6 4.9 1.9 4 0.5 5.7 2.6 0.4 0 0.4 0.4 183 8 190 305 74 0 74 0 -3.2 0.1 -2.7 -3.3 12/27/2004 00:00:00 3.9 0.6 5.3 2.3 3.9 0.6 5.3 2.3 0.4 0 0.4 0.4 193 7 206 305 74 0 74 0 -3.1 0 -2.7 -3.3 12/27/2004 00:10:00 3 0.4 4.2 1.5 3 0.5 4.2 1.9 0.4 0 0.4 0.4 193 6 196 305 74 0 74 0 -3.1 0.1 -2.7 -3.3 12/27/2004 00:20:00 3.4 0.5 4.6 2.3 3.5 0.5 4.6 2.3 0.4 0 0.4 0.4 191 5 192 305 74 0 74 0 -3.1 0.1 -2.4 -3.3 12/27/2004 00:30:00 3.5 0.3 4.6 2.6 3.5 0.4 4.6 2.3 0.4 0 0.4 0.4 192 3 198 305 74 0 74 0 -3 0 -2.4 -3.1 12/27/2004 00:40:00 4.4 0.6 5.3 3.4 4.2 0.6 5.3 2.6 0.4 0 0.4 0.4 197 3 195 305 74 0 74 0 -3 0.1 -2.4 -3.1 12/27/2004 00:50:00 4.3 0.6 5.7 3 4.2 0.6 5.3 2.6 0.4 0 0.4 0.4 195 4 202 305 74 0 74 0 -3.1 0.1 -2.4 -3.3 12/27/2004 01:00:00 4.6 0.4 5.7 3.4 4.3 0.5 5.7 3 0.4 0 0.4 0.4 201 3 204 305 74 0 74 0 -3.1 0.1 -2.7 -3.3 12/27/2004 01:10:00 5 0.3 5.7 3.8 4.8 0.3 5.3 3.8 0.4 0 0.4 0.4 204 3 204 305 74 0 74 0 -3.1 0.1 -2.7 -3.3 12/27/2004 01:20:00 5.4 0.4 6.5 4.6 5.1 0.4 6.5 3.8 0.4 0 0.4 0.4 205 5 209 305 74 0 74 0 -3 0 -2.4 -3.1 12/27/2004 01:30:00 5.3 0.3 6.1 4.6 5.1 0.3 6.1 3.8 0.4 0 0.4 0.4 205 4 202 305 74 0 74 0 -3.1 0 -2.9 -3.3 12/27/2004 01:40:00 5.3 0.4 6.8 4.6 5 0.4 6.1 3.8 0.4 0 0.4 0.4 211 5 224 305 75 0 74 0 -3.4 0 -3.1 -3.6 12/27/2004 01:50:00 5.3 0.5 6.5 3.8 4.8 0.5 6.5 3.4 0.4 0 0.4 0.4 217 5 221 305 75 0 75 0 -3.5 0 -3.3 -3.8 12/27/2004 02:00:00 4.8 0.5 6.5 3.4 4.4 0.4 5.7 3 0.4 0 0.4 0.4 211 7 214 305 75 0 74 0 -3.7 0.1 -3.3 -4 12/27/2004 02:10:00 5.1 0.4 6.5 4.2 4.9 0.4 6.1 4.2 0.4 0 0.4 0.4 199 5 194 305 75 0 75 0 -4.1 0.2 -3.8 -4.5 12/27/2004 02:20:00 5.6 0.6 6.8 4.2 5.4 0.6 6.8 3.8 0.4 0 0.4 0.4 197 5 203 305 75 0 75 0 -4.4 0 -4.2 -4.7 12/27/2004 02:30:00 6.3 0.6 8 4.6 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 198 6 209 305 75 0 75 0 -4.6 0 -4.5 -4.7 12/27/2004 02:40:00 6.2 0.5 7.6 4.2 5.9 0.6 7.6 4.2 0.4 0 0.4 0.4 198 6 199 305 75 0 74 0 -4.4 0.1 -4 -4.7 12/27/2004 02:50:00 6.2 0.5 7.6 4.6 5.9 0.6 7.2 4.2 0.4 0 0.4 0.4 200 6 208 305 74 0 74 0 -4.2 0 -4 -4.2 12/27/2004 03:00:00 7.1 0.4 8.4 6.1 6.7 0.4 8 5.3 0.4 0 0.4 0.4 207 4 203 305 74 0 74 0 -3.9 0 -3.6 -4 12/27/2004 03:10:00 7.3 0.6 9.1 5.7 6.8 0.6 8.8 5.3 0.4 0 0.4 0.4 210 4 208 305 74 0 74 0 -3.6 0 -3.3 -3.8 12/27/2004 03:20:00 7.3 0.5 8.8 6.1 6.9 0.5 8.4 5.7 0.4 0 0.4 0.4 208 3 206 305 74 0 74 0 -3.5 0 -3.3 -3.8 12/27/2004 03:30:00 7.7 0.6 9.1 6.1 7.1 0.6 8.8 5.3 0.4 0 0.4 0.4 213 7 221 305 74 0 74 0 -3.3 0 -3.1 -3.3 12/27/2004 03:40:00 8.6 1 11.1 5.7 7.7 1 10.3 5.3 0.4 0 0.4 0.4 223 6 234 305 74 0 74 0 -3.1 0 -2.9 -3.3 12/27/2004 03:50:00 9.3 0.8 11.5 7.2 8.6 1 10.7 6.5 0.4 0 0.4 0.4 226 5 224 305 72 0 72 0 -3.1 0 -2.9 -3.3 12/27/2004 04:00:00 9.4 0.8 11.8 6.8 8.6 1 11.1 6.5 0.4 0 0.4 0.4 228 5 225 305 72 0 73 0 -3.3 0 -2.7 -3.3 12/27/2004 04:10:00 9 0.8 11.1 7.2 8.3 0.8 10.7 5.7 0.4 0 0.4 0.4 228 5 233 305 70 0 70 0 -3.6 0.2 -3.1 -3.8 12/27/2004 04:20:00 8.1 0.7 9.9 6.1 7.3 0.8 9.5 5.3 0.4 0 0.4 0.4 224 6 234 305 70 0 70 0 -4 0.2 -3.3 -4.5 12/27/2004 04:30:00 8.3 0.7 10.3 6.5 7.4 0.8 9.1 5.3 0.4 0 0.4 0.4 223 5 218 305 70 0 70 0 -4.4 0.1 -3.8 -4.7 12/27/2004 04:40:00 7.9 0.5 9.1 6.1 7.1 0.7 8.8 4.9 0.4 0 0.4 0.4 217 5 221 305 68 2 70 0 -4.6 0.1 -4 -4.7 12/27/2004 04:50:00 7.8 0.6 9.5 5.3 7.2 0.7 8.8 5.3 0.4 0 0.4 0.4 215 5 214 305 66 0 66 0 -4.7 0.2 -4 -5.1 12/27/2004 05:00:00 7.6 0.5 9.5 5.7 7.3 0.5 9.1 6.1 0.4 0 0.4 0.4 207 7 222 305 65 0 65 0 -5.2 0 -4.7 -5.6 12/27/2004 05:10:00 7.5 0.5 8.8 6.1 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 204 6 213 305 65 0 65 0 -5.2 0 -4.7 -5.6 12/27/2004 05:20:00 7.1 0.5 8.8 5.7 6.9 0.5 8.8 5.3 0.4 0 0.4 0.4 209 6 211 305 65 0 65 0 -5.5 0 -5.1 -5.8 12/27/2004 05:30:00 8.2 0.8 10.3 6.1 7.4 0.8 9.1 4.6 0.4 0 0.4 0.4 220 5 225 305 64 0 65 0 -5.7 0.2 -5.1 -6 12/27/2004 05:40:00 8.5 0.6 9.9 6.8 7.8 0.7 9.5 5.7 0.4 0 0.4 0.4 217 5 217 305 65 0 65 0 -5.2 0.1 -4.9 -5.6 12/27/2004 05:50:00 7.8 0.5 9.1 6.1 7.5 0.5 9.1 5.7 0.4 0 0.4 0.4 206 5 215 305 65 0 65 0 -5.6 0 -5.3 -5.8 12/27/2004 06:00:00 8 0.5 9.5 6.8 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 209 4 212 305 65 0 66 0 -5.8 0.1 -5.6 -6 12/27/2004 06:10:00 8.4 0.5 9.9 6.8 8.2 0.5 9.9 6.8 0.4 0 0.4 0.4 202 6 192 305 66 0 66 0 -5.9 0.1 -5.6 -6.2 12/27/2004 06:20:00 8.2 0.6 10.3 6.1 7.9 0.6 9.5 5.7 0.4 0 0.4 0.4 201 5 204 305 65 0 65 0 -6.1 0 -6 -6.2 12/27/2004 06:30:00 7.8 0.5 9.5 6.8 7.7 0.6 9.9 6.1 0.4 0 0.4 0.4 200 5 203 305 65 0 66 0 -6.1 0 -6 -6.2 12/27/2004 06:40:00 8.1 0.6 9.5 6.5 7.9 0.6 9.9 6.5 0.4 0 0.4 0.4 200 5 194 305 66 0 66 0 -6 0 -5.8 -6 12/27/2004 06:50:00 8.1 0.8 11.5 6.5 7.5 0.8 10.7 5.3 0.4 0 0.4 0.4 215 10 236 305 66 0 66 0 -5.9 0.1 -5.6 -6 12/27/2004 07:00:00 8.8 0.8 10.7 6.1 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 232 6 229 305 68 0 67 0 -4.7 0.3 -4.5 -5.6 12/27/2004 07:10:00 8.8 1 11.8 6.5 7.9 0.9 10.7 5.3 0.4 0 0.4 0.4 236 6 238 305 68 0 68 0 -4.4 0 -4.2 -4.7 12/27/2004 07:20:00 9.2 0.9 11.1 6.8 8.3 1 10.7 5.7 0.4 0 0.4 0.4 237 6 235 305 68 0 68 0 -4.2 0 -4 -4.5 12/27/2004 07:30:00 8.7 0.8 11.1 6.8 7.8 0.8 9.9 5.3 0.4 0 0.4 0.4 236 6 241 305 68 0 68 0 -4.3 0 -4 -4.5 12/27/2004 07:40:00 8.3 0.7 10.3 6.5 7.6 0.8 9.5 5.3 0.4 0 0.4 0.4 236 5 237 305 68 0 68 0 -4.4 0 -4.2 -4.5 12/27/2004 07:50:00 8.2 0.8 9.9 5.7 7.5 0.8 9.9 5.7 0.4 0 0.4 0.4 235 6 224 305 68 0 67 0 -4.4 0 -4.2 -4.5 12/27/2004 08:00:00 8.1 0.8 9.9 5.3 7.3 0.9 9.5 4.6 0.4 0 0.4 0.4 238 6 240 305 68 0 68 0 -4.2 0 -4 -4.5 12/27/2004 08:10:00 8.7 0.9 11.1 6.1 7.9 0.9 10.3 5.3 0.4 0 0.4 0.4 241 6 247 305 68 0 68 0 -4.1 0 -3.8 -4.2 12/27/2004 08:20:00 8.5 0.9 11.1 6.1 7.7 1 10.7 5.3 0.4 0 0.4 0.4 245 7 248 305 69 0 69 0 -3.9 0 -3.3 -4 12/27/2004 08:30:00 8.1 1.2 11.5 5.3 7 1.2 10.7 4.6 0.4 0 0.4 0.4 258 8 256 305 69 0 69 0 -3.8 0 -3.3 -3.8 12/27/2004 08:40:00 9 1.3 11.8 5.7 7.3 1.3 10.7 4.2 0.4 0 0.4 0.4 266 8 272 305 69 0 69 0 -3.6 0 -3.3 -3.8 12/27/2004 08:50:00 9.3 1 11.8 6.8 8.4 1.2 11.1 5.7 0.4 0 0.4 0.4 254 8 252 305 69 0 69 0 -3.5 0 -3.1 -3.8 12/27/2004 09:00:00 9.9 1.2 13 6.1 8.7 1.4 12.2 4.6 0.4 0 0.4 0.4 256 7 262 305 68 1 69 0 -3.7 0.1 -3.3 -3.8 12/27/2004 09:10:00 11.4 1.2 14.9 7.2 9.8 1.3 13.3 6.5 0.4 0 0.4 0.4 260 7 256 305 66 1 65 0 -4.1 0.1 -3.8 -4.5 12/27/2004 09:20:00 11.3 1.5 14.5 6.1 9.7 1.6 13.7 4.9 0.4 0 0.4 0.4 258 7 262 305 63 1 62 0 -4.4 0 -4 -4.7 12/27/2004 09:30:00 10.5 1.7 14.1 6.1 9.2 1.7 13.3 4.6 0.4 0 0.4 0.4 256 7 257 305 61 0 62 0 -4.6 0 -4.5 -4.7 12/27/2004 09:40:00 9.3 1.2 12.6 6.5 8 1.2 11.5 4.9 0.4 0 0.4 0.4 257 7 259 305 60 0 60 0 -4.5 0 -4.2 -4.7 12/27/2004 09:50:00 11.3 1.5 15.3 7.2 9.4 1.4 13.3 6.1 0.4 0 0.4 0.4 262 9 261 305 60 0 60 0 -4.4 0 -4.2 -4.5 12/27/2004 10:00:00 11.8 1.3 14.5 7.6 9.5 1.2 13 6.5 0.4 0 0.4 0.4 269 8 270 305 59 0 59 0 -4.6 0 -4.5 -4.7 12/27/2004 10:10:00 11.3 1.5 14.5 7.2 9 1.3 12.6 6.1 0.4 0 0.4 0.4 265 7 258 305 59 0 59 0 -4.9 0 -4.5 -5.1 12/27/2004 10:20:00 11.3 1.7 14.9 6.5 9.1 1.3 12.6 5.7 0.4 0 0.4 0.4 265 8 267 305 59 0 59 0 -5.1 0 -4.7 -5.1 12/27/2004 10:30:00 12.1 1.8 15.6 7.2 9.7 1.7 13.3 5.7 0.4 0 0.4 0.4 265 7 267 305 59 0 59 0 -5.1 0 -4.7 -5.3 12/27/2004 10:40:00 12.6 1.6 16.4 8 10.1 1.5 13.7 6.1 0.4 0 0.4 0.4 269 8 270 305 59 0 59 0 -5.2 0 -5.1 -5.3 12/27/2004 10:50:00 11.6 1.7 15.6 7.2 9.2 1.6 13.7 5.3 0.4 0 0.4 0.4 268 9 262 305 59 0 59 0 -5.5 0 -5.1 -5.8 12/27/2004 11:00:00 11.7 2.1 15.6 5.7 9.4 1.7 13.3 3.8 0.4 0 0.4 0.4 267 8 266 305 58 0 58 0 -5.6 0 -5.6 -5.8 12/27/2004 11:10:00 11 1.8 16.1 5.7 8.9 1.5 13.7 5.3 0.4 0 0.4 0.4 267 9 252 305 58 0 58 0 -5.6 0 -5.6 -5.8 12/27/2004 11:20:00 12.2 1.6 15.6 7.6 10 1.4 13.7 6.5 0.4 0 0.4 0.4 263 7 271 305 58 0 58 0 -5.7 0 -5.6 -5.8 12/27/2004 11:30:00 11.9 1.6 15.6 7.2 9.7 1.4 13 5.3 0.4 0 0.4 0.4 262 7 263 305 58 0 58 0 -5.7 0 -5.6 -5.8 12/27/2004 11:40:00 10.5 1.5 14.1 6.5 8.6 1.4 12.2 5.3 0.4 0 0.4 0.4 263 8 262 305 58 0 58 0 -5.6 0 -5.3 -5.8 12/27/2004 11:50:00 11.8 1.7 15.6 7.2 9.7 1.5 13.7 6.5 0.4 0 0.4 0.4 267 7 268 305 58 0 58 0 -5.5 0 -5.3 -5.6 12/27/2004 12:00:00 11.9 1.6 16.1 6.8 9.8 1.5 13.3 5.7 0.4 0 0.4 0.4 264 8 265 305 58 0 59 0 -5.4 0 -5.1 -5.6 12/27/2004 12:10:00 11.8 1.5 15.3 8 9.6 1.4 13.7 6.5 0.4 0 0.4 0.4 262 7 262 305 59 0 59 0 -5.3 0 -5.1 -5.6 12/27/2004 12:20:00 11.8 1.7 16.1 7.6 9.7 1.7 14.1 4.9 0.4 0 0.4 0.4 261 7 264 305 59 0 59 0 -5.1 0 -4.9 -5.3 12/27/2004 12:30:00 12.8 1.9 18.7 8.4 11 2.2 16.8 5.7 0.4 0 0.4 0.4 274 11 283 305 59 0 59 0 -5 0 -4.7 -5.1 12/27/2004 12:40:00 15 1.5 17.9 9.9 13.7 1.8 17.6 8.4 0.4 0 0.4 0.4 283 7 288 305 58 0 58 0 -5.3 0.1 -4.9 -5.6 12/27/2004 12:50:00 13.8 1.7 17.9 9.9 12.8 1.8 16.4 8.8 0.4 0 0.4 0.4 288 8 285 305 57 0 57 0 -5.6 0 -5.6 -5.8 12/27/2004 13:00:00 14.5 1.6 18.7 9.1 13.2 1.5 17.6 9.1 0.4 0 0.4 0.4 284 6 287 305 56 0 56 0 -5.9 0 -5.8 -6 12/27/2004 13:10:00 13.5 1.7 17.2 9.1 12.1 1.5 16.8 8.4 0.4 0 0.4 0.4 282 8 272 305 55 0 55 0 -6 0 -5.8 -6.2 12/27/2004 13:20:00 13.7 2 17.6 7.2 12.1 2.2 16.8 5.7 0.4 0 0.4 0.4 279 7 279 305 55 0 55 0 -6.2 0 -6 -6.4 12/27/2004 13:30:00 13.6 1.5 17.6 9.9 12.7 1.6 17.2 9.1 0.4 0 0.4 0.4 288 13 287 305 54 0 54 0 -6.4 0 -6.2 -6.7 12/27/2004 13:40:00 13.5 1.6 17.9 9.9 11.9 1.7 17.2 8 0.4 0 0.4 0.4 279 8 292 305 54 0 54 0 -6.4 0 -6.2 -6.7 12/27/2004 13:50:00 13.1 2.2 17.6 7.6 11.6 2.1 16.4 6.5 0.4 0 0.4 0.4 281 7 279 305 54 0 54 0 -6.6 0 -6.4 -6.9 12/27/2004 14:00:00 13.9 1.5 16.8 10.3 12.7 1.7 16.8 8.4 0.4 0 0.4 0.4 285 8 280 305 54 0 54 0 -6.6 0 -6.4 -6.7 12/27/2004 14:10:00 13.1 1.7 16.4 7.6 12.5 1.8 16.1 6.8 0.4 0 0.4 0.4 290 7 294 305 54 0 54 0 -6.5 0 -6.2 -6.7 12/27/2004 14:20:00 13.1 1.3 15.6 9.9 12.4 1.4 15.6 8.8 0.4 0 0.4 0.4 290 9 200 305 54 0 54 0 -6.6 0 -6.4 -6.7 12/27/2004 14:30:00 13.1 1.8 17.6 8.8 12.3 2 16.4 7.6 0.4 0 0.4 0.4 287 6 291 305 54 0 54 0 -6.5 0 -6.4 -6.9 12/27/2004 14:40:00 12.2 1.5 16.1 8.8 11.3 1.7 16.1 7.2 0.4 0 0.4 0.4 285 8 286 305 54 0 54 0 -6.5 0 -6.4 -6.7 12/27/2004 14:50:00 12.2 1.6 15.6 7.6 10.9 1.9 15.6 6.5 0.4 0 0.4 0.4 282 11 286 305 54 0 53 0 -6.7 0 -6.7 -6.9 12/27/2004 15:00:00 11.6 1.4 14.5 8 10.8 1.5 14.1 6.8 0.4 0 0.4 0.4 287 14 279 305 53 0 53 0 -6.9 0 -6.7 -7.1 12/27/2004 15:10:00 11.7 1.4 14.9 8.4 10.7 1.5 14.1 7.2 0.4 0 0.4 0.4 285 8 286 305 53 0 53 0 -6.9 0 -6.7 -7.1 12/27/2004 15:20:00 12 1.5 16.1 8 11.2 1.7 14.9 6.8 0.4 0 0.4 0.4 285 8 284 305 53 0 53 0 -7 0 -6.9 -7.3 12/27/2004 15:30:00 12.4 1.2 15.3 9.1 12 1.3 14.5 8 0.4 0 0.4 0.4 294 19 297 305 52 0 52 0 -7.2 0 -7.1 -7.5 12/27/2004 15:40:00 12.2 1.5 14.9 7.2 11.2 1.5 14.1 6.5 0.4 0 0.4 0.4 282 6 283 305 51 0 51 0 -7.5 0 -7.3 -7.7 12/27/2004 15:50:00 11.3 1.4 14.1 7.2 10.3 1.5 13.3 6.8 0.4 0 0.4 0.4 283 7 284 305 51 0 51 0 -7.7 0 -7.5 -7.7 12/27/2004 16:00:00 10.8 2 14.5 6.5 9.8 2.1 14.5 5.3 0.4 0 0.4 0.4 284 8 293 305 50 0 51 0 -7.7 0 -7.7 -7.9 12/27/2004 16:10:00 12 1.5 16.1 8.4 11.2 1.7 14.9 7.2 0.4 0 0.4 0.4 287 9 278 305 50 0 50 0 -7.8 0 -7.7 -7.9 12/27/2004 16:20:00 11.9 1.2 14.9 8.8 10.9 1.5 14.5 6.8 0.4 0 0.4 0.4 284 8 290 305 49 0 49 0 -7.8 0 -7.7 -7.9 12/27/2004 16:30:00 11.7 1.6 14.9 6.8 10.6 1.7 14.5 5.7 0.4 0 0.4 0.4 284 7 281 305 49 0 48 0 -7.8 0 -7.7 -7.9 12/27/2004 16:40:00 11.4 1.9 16.1 7.2 10 1.9 14.9 5.3 0.4 0 0.4 0.4 282 8 287 305 48 0 48 0 -8 0 -7.7 -8.2 12/27/2004 16:50:00 10.4 1.2 13.7 7.2 9.8 1.2 13.3 6.5 0.4 0 0.4 0.4 290 11 287 305 47 0 47 0 -8.1 0 -7.9 -8.2 12/27/2004 17:00:00 9.2 1.5 13 5.3 8.8 1.4 12.2 5.3 0.4 0 0.4 0.4 293 10 290 305 48 1 47 0 -8.1 0 -7.7 -8.2 12/27/2004 17:10:00 10.5 1.7 14.1 6.1 9.6 1.7 13 5.7 0.4 0 0.4 0.4 285 8 270 305 49 0 49 0 -7.9 0 -7.7 -7.9 12/27/2004 17:20:00 10.2 1.5 13.3 5.7 8.6 1.5 11.8 4.9 0.4 0 0.4 0.4 273 8 285 305 49 0 49 0 -7.9 0 -7.7 -7.9 12/27/2004 17:30:00 12.3 1.4 14.9 6.8 10.7 1.6 14.5 6.8 0.4 0 0.4 0.4 279 7 280 305 48 0 48 0 -8 0 -7.7 -8.2 12/27/2004 17:40:00 10.5 1.3 14.5 6.8 10 1.4 13.3 5.3 0.4 0 0.4 0.4 292 14 289 305 47 1 47 0 -8.2 0 -7.9 -8.4 12/27/2004 17:50:00 11.5 1.3 14.1 8.4 9.8 1.1 12.6 6.1 0.4 0 0.4 0.4 278 9 284 305 46 0 46 0 -8.2 0 -7.9 -8.4 12/27/2004 18:00:00 10.4 1.3 13.7 6.8 9.5 1.3 12.6 6.1 0.4 0 0.4 0.4 286 8 285 305 46 0 46 0 -8.3 0 -8.2 -8.4 12/27/2004 18:10:00 9.6 1 12.2 7.2 8.9 1 11.8 6.5 0.4 0 0.4 0.4 288 7 282 305 46 0 46 0 -8.2 0 -7.9 -8.4 12/27/2004 18:20:00 9.6 0.9 12.2 7.2 9 1 11.5 6.1 0.4 0 0.4 0.4 290 13 299 305 46 0 46 0 -8.3 0 -8.2 -8.4 12/27/2004 18:30:00 8.2 1.2 11.1 5.3 7.7 1.2 10.3 4.6 0.4 0 0.4 0.4 286 9 288 305 46 0 46 0 -8.2 0 -8.2 -8.4 12/27/2004 18:40:00 9.6 1.3 12.6 6.5 9 1.3 11.8 5.7 0.4 0 0.4 0.4 286 6 289 305 47 0 47 0 -8.2 0 -7.9 -8.4 12/27/2004 18:50:00 9.7 1 11.8 6.8 8.9 1 11.5 5.3 0.4 0 0.4 0.4 284 7 290 305 47 0 47 0 -8.2 0 -8.2 -8.4 12/27/2004 19:00:00 8.5 1 11.1 6.1 7.9 1 10.3 5.7 0.4 0 0.4 0.4 289 7 284 305 46 0 46 0 -8.3 0 -8.2 -8.4 12/27/2004 19:10:00 8.7 0.9 10.7 6.8 8.5 0.9 10.7 6.5 0.4 0 0.4 0.4 296 17 301 305 46 0 46 0 -8.4 0.1 -8.2 -8.6 12/27/2004 19:20:00 8.3 0.7 9.9 6.1 8 0.7 9.5 5.7 0.4 0 0.4 0.4 297 19 287 305 46 0 46 0 -8.5 0 -8.4 -8.6 12/27/2004 19:30:00 8.1 0.9 10.3 5.7 7.6 1 10.3 4.9 0.4 0 0.4 0.4 290 7 291 305 46 0 46 0 -8.5 0 -8.4 -8.6 12/27/2004 19:40:00 7.9 0.9 10.3 5.7 7.2 1.1 10.3 4.9 0.4 0 0.4 0.4 283 8 283 305 46 0 46 0 -8.6 0 -8.4 -8.8 12/27/2004 19:50:00 6.7 1.3 9.1 4.2 6.2 1.2 9.1 3.4 0.4 0 0.4 0.4 285 8 285 305 46 0 46 0 -8.7 0 -8.4 -8.8 12/27/2004 20:00:00 7.3 1 9.5 4.2 6.4 1 8.4 3.4 0.4 0 0.4 0.4 281 8 282 305 46 0 46 0 -8.7 0 -8.4 -8.8 12/27/2004 20:10:00 6.5 0.9 8.8 4.6 5.8 0.9 8.4 3.8 0.4 0 0.4 0.4 278 6 276 305 47 0 47 0 -8.6 0 -8.4 -8.8 12/27/2004 20:20:00 6.6 0.9 8.8 4.6 5.5 1 8.8 3 0.4 0 0.4 0.4 274 7 276 305 48 0 47 0 -8.5 0 -8.4 -8.6 12/27/2004 20:30:00 6.7 0.9 8.8 4.6 5.9 1 8.4 3.8 0.4 0 0.4 0.4 283 13 286 305 48 0 48 0 -8.5 0 -8.4 -8.6 12/27/2004 20:40:00 7 1 9.5 4.6 6.3 1.1 8.8 3 0.4 0 0.4 0.4 286 7 295 305 48 0 48 0 -8.4 0 -8.2 -8.6 12/27/2004 20:50:00 6.6 0.6 8.4 4.6 5.9 0.7 8.4 4.6 0.4 0 0.4 0.4 282 8 279 305 48 0 48 0 -8.4 0 -8.2 -8.4 12/27/2004 21:00:00 6.4 1.2 8.8 3.8 5.8 1.1 8 2.6 0.4 0 0.4 0.4 285 12 290 305 48 0 48 0 -8.3 0 -8.2 -8.4 12/27/2004 21:10:00 7.5 0.9 9.9 5.3 6.8 0.9 8.8 4.2 0.4 0 0.4 0.4 286 9 288 305 48 0 48 0 -8.2 0 -8.2 -8.4 12/27/2004 21:20:00 7.3 0.8 9.1 4.9 7 0.8 8.8 4.9 0.4 0 0.4 0.4 294 15 278 305 49 0 48 0 -8.2 0 -8.2 -8.4 12/27/2004 21:30:00 8.1 0.9 10.7 5.7 7.3 1.2 9.5 4.2 0.4 0 0.4 0.4 283 7 286 305 49 0 49 0 -8.3 0 -8.2 -8.4 12/27/2004 21:40:00 7.5 0.8 9.1 6.1 6.8 0.8 8.8 4.9 0.4 0 0.4 0.4 283 6 283 305 48 0 48 0 -8.3 0 -7.7 -8.4 12/27/2004 21:50:00 7 1 9.5 4.6 6.3 1.1 9.1 4.2 0.4 0 0.4 0.4 281 7 288 305 48 0 48 0 -8.2 0 -8.2 -8.4 12/27/2004 22:00:00 8 0.8 9.9 5.7 6.9 0.9 9.1 4.2 0.4 0 0.4 0.4 280 7 282 305 49 0 49 0 -8.2 0 -8.2 -8.4 12/27/2004 22:10:00 7.1 0.9 9.5 4.6 6.7 0.9 9.1 4.2 0.4 0 0.4 0.4 286 7 282 305 49 0 49 0 -8.2 0 -8.2 -8.4 12/27/2004 22:20:00 7 0.7 8.4 4.9 6.4 0.8 8.4 4.2 0.4 0 0.4 0.4 287 7 297 305 48 0 48 0 -8.3 0 -8.2 -8.4 12/27/2004 22:30:00 6.5 0.7 8 4.6 6.1 0.8 8 3.8 0.4 0 0.4 0.4 291 9 279 305 48 0 48 0 -8.3 0 -8.2 -8.4 12/27/2004 22:40:00 6.6 0.7 8 4.6 6.1 0.8 8 4.6 0.4 0 0.4 0.4 289 7 285 305 49 0 48 0 -8.3 0 -8.2 -8.4 12/27/2004 22:50:00 5.8 0.7 7.2 4.2 5.4 0.8 7.2 3.4 0.4 0 0.4 0.4 286 7 282 305 49 0 49 0 -8.2 0 -8.2 -8.4 12/27/2004 23:00:00 5.4 0.7 7.6 3.8 5.1 0.8 6.8 3.8 0.4 0 0.4 0.4 295 16 291 305 50 1 50 0 -8.2 0 -7.9 -8.4 12/27/2004 23:10:00 5.9 0.8 7.6 4.6 5.7 0.8 7.6 3.8 0.4 0 0.4 0.4 301 17 296 305 50 1 49 0 -8.2 0 -7.9 -8.4 12/27/2004 23:20:00 5.7 0.4 6.8 4.2 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 309 23 300 305 50 1 48 0 -8.3 0 -8.2 -8.4 12/27/2004 23:30:00 5.5 0.5 7.2 4.2 5.3 0.5 7.2 4.2 0.4 0 0.4 0.4 302 22 294 305 49 1 49 0 -8.2 0 -8.2 -8.4 12/27/2004 23:40:00 4 0.5 5.3 3 3.8 0.5 4.9 2.6 0.4 0 0.4 0.4 301 12 302 305 48 1 51 0 -8.5 0.1 -8.2 -8.8 12/27/2004 23:50:00 3.1 0.4 4.2 1.9 2.7 0.5 4.2 1.5 0.4 0 0.4 0.4 295 15 285 305 48 1 47 0 -8.6 0 -8.4 -8.8 12/28/2004 00:00:00 3.3 0.4 4.9 2.3 2.7 0.5 4.6 1.5 0.4 0 0.4 0.4 281 9 288 305 48 0 50 0 -8.4 0 -7.9 -8.6 12/28/2004 00:10:00 3.5 0.4 4.6 2.3 3 0.5 4.2 1.5 0.4 0 0.4 0.4 290 9 285 305 49 0 49 0 -8.2 0 -7.7 -8.4 12/28/2004 00:20:00 2.4 0.5 4.2 1.5 1.8 0.5 3.4 1.1 0.4 0 0.4 0.4 277 8 285 305 49 0 50 0 -8.3 0 -7.7 -8.6 12/28/2004 00:30:00 1.3 0.5 2.6 0.4 1.2 0.3 1.9 0.4 0.4 0 0.4 0.4 261 16 301 305 49 0 49 0 -8.7 0 -8.4 -9 12/28/2004 00:40:00 1.2 0.6 2.6 0.4 1.3 0.5 2.6 0.4 0.4 0 0.4 0.4 238 16 232 305 49 0 49 0 -8.9 0 -8.4 -9.2 12/28/2004 00:50:00 1.9 0.4 2.6 1.1 2 0.4 3 1.1 0.4 0 0.4 0.4 238 14 246 305 49 0 49 0 -8.9 0.1 -8.4 -9.2 12/28/2004 01:00:00 2.3 0.5 3.4 1.1 2.4 0.5 3.8 1.5 0.4 0 0.4 0.4 225 20 205 305 50 1 50 0 -9.2 0 -8.8 -9.4 12/28/2004 01:10:00 3.1 0.4 4.2 1.9 3.2 0.4 4.2 1.9 0.4 0 0.4 0.4 208 11 213 305 52 1 52 0 -9.3 0 -8.8 -9.4 12/28/2004 01:20:00 3.9 0.4 4.9 3 4 0.3 4.9 3 0.4 0 0.4 0.4 202 5 203 305 54 1 55 0 -9.3 0 -9 -9.4 12/28/2004 01:30:00 4 0.4 4.9 3 4.1 0.4 5.3 2.6 0.4 0 0.4 0.4 195 7 205 305 56 0 56 0 -9.5 0 -9.2 -9.6 12/28/2004 01:40:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.6 0.4 0 0.4 0.4 206 10 196 305 56 0 56 0 -9.4 0.1 -9 -9.6 12/28/2004 01:50:00 3.5 0.4 4.6 2.6 3.6 0.3 4.6 3 0.4 0 0.4 0.4 209 7 208 305 56 0 57 0 -9.4 0 -8.8 -9.4 12/28/2004 02:00:00 3.2 0.4 4.2 2.3 3.3 0.4 4.6 1.9 0.4 0 0.4 0.4 204 7 216 305 56 0 56 0 -9.5 0 -9.2 -9.6 12/28/2004 02:10:00 4.3 0.3 5.3 3.4 4.3 0.3 4.9 3.4 0.4 0 0.4 0.4 207 6 210 305 56 0 56 0 -9.6 0.1 -9.2 -9.8 12/28/2004 02:20:00 4.4 0.4 5.3 2.6 4.4 0.5 5.7 3 0.4 0 0.4 0.4 206 8 224 305 57 0 57 0 -9.7 0 -9.2 -9.8 12/28/2004 02:30:00 4.2 0.4 5.7 3.4 4.2 0.4 5.3 3.4 0.4 0 0.4 0.4 207 8 205 305 57 0 57 0 -9.8 0 -9.6 -10 12/28/2004 02:40:00 4.4 0.4 5.7 3 4.4 0.4 5.7 3 0.4 0 0.4 0.4 207 8 209 305 56 0 56 0 -9.8 0 -9.6 -10 12/28/2004 02:50:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 0.4 0 0.4 0.4 202 9 208 305 56 0 57 0 -10 0.1 -9.6 -10.2 12/28/2004 03:00:00 3.2 0.4 4.6 2.3 3.1 0.4 4.2 2.3 0.4 0 0.4 0.4 215 11 213 305 56 0 56 0 -9.9 0 -9.6 -10.2 12/28/2004 03:10:00 3 0.4 3.8 1.9 3.1 0.3 4.2 2.3 0.4 0 0.4 0.4 200 8 197 305 56 0 56 0 -10 0 -9.8 -10.2 12/28/2004 03:20:00 2.8 0.4 3.4 1.9 2.9 0.4 3.8 1.5 0.4 0 0.4 0.4 203 8 208 305 56 0 57 0 -10 0 -9.8 -10 12/28/2004 03:30:00 3 0.4 3.8 1.9 3.1 0.4 4.2 1.9 0.4 0 0.4 0.4 200 7 215 305 57 0 57 0 -9.9 0 -9.6 -10 12/28/2004 03:40:00 2.5 0.3 3.4 1.5 2.6 0.3 3.4 1.9 0.4 0 0.4 0.4 200 7 203 305 57 0 57 0 -9.8 0 -9.6 -10 12/28/2004 03:50:00 2.3 0.3 3 1.1 2.5 0.3 3.4 1.5 0.4 0 0.4 0.4 198 5 203 305 58 0 58 0 -9.9 0 -9.6 -10 12/28/2004 04:00:00 1.7 0.4 2.6 0.7 2.1 0.4 3 1.5 0.4 0 0.4 0.4 191 3 194 305 57 0 57 0 -10 0 -9.8 -10.2 12/28/2004 04:10:00 1 0.6 2.3 0.4 1.8 0.4 2.6 1.1 0.4 0 0.4 0.4 182 2 181 305 58 0 58 0 -10 0 -9.8 -10.2 12/28/2004 04:20:00 1.2 0.4 2.3 0.4 1.9 0.3 2.6 1.1 0.4 0 0.4 0.4 171 5 165 305 57 0 57 0 -10.1 0.1 -9.6 -10.4 12/28/2004 04:30:00 1.5 0.4 2.3 0.4 1.9 0.2 2.6 1.5 0.4 0 0.4 0.4 189 15 175 305 58 0 59 0 -9.4 0.1 -9.2 -9.8 12/28/2004 04:40:00 2 0.3 2.6 1.1 2.4 0.3 3 1.9 0.4 0 0.4 0.4 201 12 188 305 58 0 58 0 -9.8 0.2 -9.2 -10.2 12/28/2004 04:50:00 2.5 0.3 3.4 1.9 2.9 0.3 3.8 2.3 0.4 0 0.4 0.4 193 5 200 305 58 0 58 0 -9.6 0.2 -9.2 -10 12/28/2004 05:00:00 3 0.4 3.8 1.9 3.4 0.3 3.8 2.6 0.4 0 0.4 0.4 195 5 195 305 57 0 58 0 -10 0 -9.8 -10.2 12/28/2004 05:10:00 1.8 0.6 3 0.4 2.6 0.4 3.4 1.5 0.4 0 0.4 0.4 182 13 189 305 57 0 57 0 -10 0.1 -9.6 -10.4 12/28/2004 05:20:00 2.3 0.6 3.4 0.7 2.7 0.5 3.8 1.5 0.4 0 0.4 0.4 190 11 189 305 58 0 58 0 -9.4 0.2 -9 -9.8 12/28/2004 05:30:00 2.9 0.8 4.2 0.7 3.2 0.7 4.6 1.5 0.4 0 0.4 0.4 183 15 194 305 58 0 58 0 -9.5 0 -9.2 -9.6 12/28/2004 05:40:00 1.8 1.1 4.2 0.4 1.6 1.2 4.6 0.4 0.4 0 0.4 0.4 135 17 140 305 59 0 58 0 -9.5 0.1 -9.2 -9.8 12/28/2004 05:50:00 2.8 0.5 4.2 1.9 3.4 0.4 4.6 2.6 0.4 0 0.4 0.4 148 7 156 305 57 0 58 0 -10 0.1 -9.6 -10.4 12/28/2004 06:00:00 2.8 0.9 5.3 1.1 3 1 5.7 1.5 0.4 0 0.4 0.4 121 12 140 305 57 0 58 0 -9.9 0.2 -9.6 -10.4 12/28/2004 06:10:00 3.7 1.5 7.2 1.5 3.4 1.4 7.2 0.7 0.4 0 0.4 0.4 114 13 115 305 58 0 59 0 -9.6 0.1 -9.2 -9.8 12/28/2004 06:20:00 6.6 1 9.5 4.2 6.6 1 9.9 4.2 0.4 0 0.4 0.4 125 11 141 305 59 0 59 0 -9 0.1 -8.8 -9.2 12/28/2004 06:30:00 7.1 0.9 9.1 3.8 7.1 0.9 9.1 4.2 0.4 0 0.4 0.4 135 8 129 305 60 0 60 0 -8.9 0 -8.8 -9.2 12/28/2004 06:40:00 6.3 0.8 8.4 3.8 6.4 0.8 8.8 4.2 0.4 0 0.4 0.4 133 9 127 305 60 0 60 0 -8.7 0.1 -8.4 -9 12/28/2004 06:50:00 6.7 1.4 9.9 3.4 6.7 1.2 9.9 3.8 0.4 0 0.4 0.4 121 11 113 305 61 0 61 0 -8.4 0.1 -8.2 -8.6 12/28/2004 07:00:00 7.9 1.3 11.5 3.4 7.9 1.3 10.7 3.4 0.4 0 0.4 0.4 118 9 129 305 61 0 61 0 -8.2 0 -7.9 -8.4 12/28/2004 07:10:00 9.6 0.8 11.8 6.8 9.5 0.9 11.8 7.2 0.4 0 0.4 0.4 121 5 121 305 61 0 61 0 -8 0 -7.7 -8.2 12/28/2004 07:20:00 10 1 12.6 7.2 9.9 0.9 12.6 7.2 0.4 0 0.4 0.4 120 6 127 305 61 0 61 0 -8 0 -7.7 -8.2 12/28/2004 07:30:00 9.4 1.3 12.6 6.5 9.3 1.3 12.6 5.3 0.4 0 0.4 0.4 116 10 118 305 61 0 61 0 -7.9 0 -7.7 -8.2 12/28/2004 07:40:00 11.7 1.3 15.6 8.4 11.7 1.2 15.3 8.8 0.4 0 0.4 0.4 114 8 121 305 60 0 60 0 -7.8 0 -7.7 -7.9 12/28/2004 07:50:00 13.1 1.1 16.1 10.3 13 1.1 15.6 10.3 0.4 0 0.4 0.4 113 7 114 305 60 0 60 0 -7.8 0 -7.7 -7.9 12/28/2004 08:00:00 14.3 1.2 16.4 9.5 14.2 1.1 16.4 11.1 0.4 0 0.4 0.4 117 6 118 305 60 0 60 0 -8 0.1 -7.3 -8.2 12/28/2004 08:10:00 15 1.1 17.9 11.1 14.8 1.1 17.6 11.5 0.4 0 0.4 0.4 119 5 121 305 60 0 60 0 -8.2 0 -7.7 -8.2 12/28/2004 08:20:00 14.3 1.4 18.3 11.1 14.3 1.3 17.6 10.7 0.4 0 0.4 0.4 121 8 113 305 61 0 60 0 -8.2 0 -7.9 -8.4 12/28/2004 08:30:00 14.9 1.2 18.3 10.3 14.7 1.1 17.6 11.1 0.4 0 0.4 0.4 118 5 120 305 60 0 60 0 -8.3 0 -8.2 -8.4 12/28/2004 08:40:00 13.5 1.4 16.8 9.1 13.2 1.3 16.8 9.9 0.4 0 0.4 0.4 118 8 113 305 61 0 61 0 -8.4 0 -8.2 -8.4 12/28/2004 08:50:00 12.3 1.7 16.8 6.8 12.2 1.7 17.9 6.8 0.4 0 0.4 0.4 119 8 131 305 61 0 61 0 -8.4 0 -8.2 -8.4 12/28/2004 09:00:00 12.5 1.7 16.8 8 12.4 1.6 16.8 7.2 0.4 0 0.4 0.4 120 9 116 305 61 0 62 0 -8.4 0 -8.2 -8.6 12/28/2004 09:10:00 13.6 1.5 17.2 8.4 13.4 1.5 17.2 8.4 0.4 0 0.4 0.4 118 9 121 305 62 0 62 0 -8.3 0 -8.2 -8.4 12/28/2004 09:20:00 15 1.6 19.5 11.1 14.9 1.6 19.5 10.3 0.4 0 0.4 0.4 121 8 109 305 62 0 62 0 -8.3 0 -8.2 -8.6 12/28/2004 09:30:00 15.4 1.3 19.1 10.3 15.3 1.3 19.9 10.3 0.4 0 0.4 0.4 120 7 135 305 61 0 62 0 -8.5 0 -8.4 -8.6 12/28/2004 09:40:00 15 1.5 19.9 11.1 14.9 1.5 20.6 10.7 0.4 0 0.4 0.4 123 9 144 305 61 0 61 0 -8.5 0 -8.4 -8.6 12/28/2004 09:50:00 15 1.5 19.9 10.7 14.8 1.5 19.9 10.7 0.4 0 0.4 0.4 121 8 114 305 61 0 61 0 -8.7 0 -8.4 -8.8 12/28/2004 10:00:00 14.3 1.3 18.7 10.7 14.2 1.3 17.9 10.3 0.4 0 0.4 0.4 124 9 114 305 61 0 61 0 -8.8 0 -8.4 -9 12/28/2004 10:10:00 13.7 1.5 17.2 9.5 13.7 1.5 17.9 9.9 0.4 0 0.4 0.4 120 9 123 305 61 0 62 0 -8.7 0 -8.2 -8.8 12/28/2004 10:20:00 13.1 1.5 17.6 8.4 13 1.6 17.6 8 0.4 0 0.4 0.4 118 8 118 305 61 0 61 0 -8.7 0 -8.2 -8.8 12/28/2004 10:30:00 11.9 1.4 16.4 8 11.7 1.5 16.4 8.4 0.4 0 0.4 0.4 119 9 121 305 62 0 63 0 -8.6 0 -8.2 -8.8 12/28/2004 10:40:00 10.3 1.5 14.1 6.5 10.2 1.5 14.9 6.1 0.4 0 0.4 0.4 124 11 118 305 62 0 62 0 -8.4 0 -7.9 -8.6 12/28/2004 10:50:00 11 2.4 16.1 6.1 10.9 2.3 16.4 6.1 0.4 0 0.4 0.4 126 12 128 305 62 0 62 0 -8.2 0 -7.9 -8.4 12/28/2004 11:00:00 11.2 1.5 14.5 7.2 11.1 1.5 14.9 6.8 0.4 0 0.4 0.4 127 11 123 305 63 1 63 0 -8 0 -7.9 -8.2 12/28/2004 11:10:00 12.6 1.5 16.1 8 12.5 1.5 17.6 8.4 0.4 0 0.4 0.4 128 11 141 305 63 0 63 0 -8 0 -7.9 -8.2 12/28/2004 11:20:00 12.5 1.8 18.3 8.4 12.4 1.7 19.1 8 0.4 0 0.4 0.4 122 11 103 305 63 0 63 0 -8 0 -7.9 -8.2 12/28/2004 11:30:00 13.3 1.7 18.3 8 13 1.8 17.9 7.2 0.4 0 0.4 0.4 123 12 123 305 63 1 63 0 -7.9 0 -7.7 -8.2 12/28/2004 11:40:00 15.1 1.7 19.1 9.9 15.1 1.7 19.1 9.5 0.4 0 0.4 0.4 131 8 130 305 62 0 63 0 -7.8 0 -7.7 -7.9 12/28/2004 11:50:00 15.3 1.2 17.9 11.5 14.9 1.2 17.6 11.8 0.4 0 0.4 0.4 131 5 133 305 62 0 62 0 -7.8 0 -7.7 -7.9 12/28/2004 12:00:00 14.9 1.1 17.9 11.5 14.6 1.1 17.9 10.7 0.4 0 0.4 0.4 132 5 128 305 63 1 62 0 -7.7 0 -7.5 -7.9 12/28/2004 12:10:00 15.8 1.2 18.7 10.7 15.5 1 17.9 10.7 0.4 0 0.4 0.4 132 5 132 305 62 0 62 0 -7.7 0 -7.7 -7.9 12/28/2004 12:20:00 16.1 1.5 19.1 11.1 15.8 1.4 19.1 11.5 0.4 0 0.4 0.4 132 6 134 305 62 0 62 0 -7.7 0 -7.5 -7.9 12/28/2004 12:30:00 15.9 1.5 19.1 10.7 15.6 1.5 19.1 10.3 0.4 0 0.4 0.4 132 7 135 305 62 0 62 0 -7.6 0 -7.3 -7.7 12/28/2004 12:40:00 15.2 1.5 20.2 9.1 15 1.5 19.9 9.5 0.4 0 0.4 0.4 130 8 143 305 62 0 62 0 -7.6 0 -7.3 -7.7 12/28/2004 12:50:00 15.1 1.7 19.5 9.9 15 1.6 19.9 11.1 0.4 0 0.4 0.4 130 8 130 305 61 0 62 0 -7.6 0 -7.5 -7.7 12/28/2004 13:00:00 13.6 1.7 18.7 9.5 13.5 1.8 19.5 9.5 0.4 0 0.4 0.4 125 12 126 305 62 0 62 0 -7.5 0 -7.3 -7.7 12/28/2004 13:10:00 14.9 2.4 20.6 8.4 14.6 2.3 21 8.4 0.4 0 0.4 0.4 120 10 117 305 62 0 62 0 -7.2 0 -7.1 -7.5 12/28/2004 13:20:00 15.3 2.3 21.8 9.9 15 2.4 21 8.8 0.4 0 0.4 0.4 122 11 124 305 63 0 63 0 -7.1 0 -6.9 -7.3 12/28/2004 13:30:00 14.7 2.5 21.8 8.8 14.7 2.4 21.4 9.1 0.4 0 0.4 0.4 122 10 112 305 63 0 63 0 -7 0 -6.9 -7.1 12/28/2004 13:40:00 14.3 2.3 19.9 7.6 14.2 2.3 19.9 8 0.4 0 0.4 0.4 122 12 126 305 64 0 63 0 -6.9 0 -6.7 -7.1 12/28/2004 13:50:00 14.9 2.2 20.6 8.8 14.7 2.3 21.4 8.4 0.4 0 0.4 0.4 120 14 116 305 64 0 64 0 -6.9 0 -6.7 -6.9 12/28/2004 14:00:00 15.6 2.3 23.3 9.1 15.5 2.3 22.9 10.3 0.4 0 0.4 0.4 125 12 132 305 64 0 65 0 -6.8 0 -6.7 -6.9 12/28/2004 14:10:00 15.6 2 22.1 9.9 15.5 2.1 21 9.5 0.4 0 0.4 0.4 130 12 135 305 64 0 65 0 -6.6 0 -6.7 -6.9 12/28/2004 14:20:00 16.7 1.9 22.6 11.5 16.6 1.8 21.4 11.1 0.4 0 0.4 0.4 133 10 119 305 64 0 64 0 -6.6 0 -6.4 -6.7 12/28/2004 14:30:00 15.7 1.6 19.5 10.7 15.6 1.7 20.2 11.5 0.4 0 0.4 0.4 133 8 132 305 65 0 65 0 -6.5 0 -6.4 -6.7 12/28/2004 14:40:00 15.6 1.6 21.4 11.1 15.2 1.7 22.1 10.3 0.4 0 0.4 0.4 133 7 130 305 65 0 65 0 -6.4 0 -6.2 -6.7 12/28/2004 14:50:00 15.5 2 21 10.3 15.5 2 20.6 9.5 0.4 0 0.4 0.4 132 10 131 305 65 1 64 0 -6.4 0 -6.2 -6.7 12/28/2004 15:00:00 16 2.1 21.8 11.1 15.8 2.1 22.6 11.5 0.4 0 0.4 0.4 131 12 133 305 65 1 65 0 -6.3 0 -6.2 -6.4 12/28/2004 15:10:00 15.3 2.4 21.4 9.9 15.1 2.2 21.8 10.3 0.4 0 0.4 0.4 128 11 124 305 65 1 67 0 -6.2 0 -6 -6.4 12/28/2004 15:20:00 15.5 2.4 22.9 9.5 15.3 2.3 22.9 8.8 0.4 0 0.4 0.4 125 13 123 305 66 2 65 0 -6.1 0 -6 -6.2 12/28/2004 15:30:00 15.7 2.2 22.6 10.7 15.6 2.1 21.8 10.3 0.4 0 0.4 0.4 122 11 108 305 65 1 65 0 -6.1 0 -5.8 -6.2 12/28/2004 15:40:00 16 2.1 22.6 10.3 15.8 2.2 22.6 10.3 0.4 0 0.4 0.4 125 12 113 305 65 1 65 0 -5.9 0 -5.8 -6 12/28/2004 15:50:00 17.1 2.2 22.1 11.8 16.7 2.1 22.6 11.5 0.4 0 0.4 0.4 131 10 138 305 66 1 68 0 -5.7 0 -5.6 -6 12/28/2004 16:00:00 18 1.5 22.6 13.7 17.3 1.5 21 13.7 0.4 0 0.4 0.4 133 6 120 305 66 1 66 0 -5.6 0 -5.6 -5.8 12/28/2004 16:10:00 18.4 1.5 21.4 14.5 17.9 1.5 21 13.7 0.4 0 0.4 0.4 134 5 139 305 66 1 66 0 -5.6 0 -5.6 -5.8 12/28/2004 16:20:00 17.9 1.3 21 14.5 17.5 1.3 20.6 13.7 0.4 0 0.4 0.4 135 5 130 305 67 2 66 0 -5.6 0 -5.6 -5.8 12/28/2004 16:30:00 17.5 1.3 20.2 13 17 1.3 19.5 13 0.4 0 0.4 0.4 135 5 134 305 67 2 69 0 -5.6 0 -5.6 -5.8 12/28/2004 16:40:00 17 1.4 20.2 13 16.5 1.3 19.9 12.6 0.4 0 0.4 0.4 133 5 134 305 66 1 66 0 -5.5 0 -5.3 -5.6 12/28/2004 16:50:00 17 1.3 20.2 13.3 16.5 1.3 19.9 13 0.4 0 0.4 0.4 131 4 131 305 66 0 66 0 -5.4 0 -5.1 -5.6 12/28/2004 17:00:00 16.1 1.2 18.7 12.2 15.6 1.1 18.3 12.6 0.4 0 0.4 0.4 133 5 128 305 66 0 66 0 -5.3 0 -5.1 -5.6 12/28/2004 17:10:00 15.7 1.2 17.9 12.6 15.3 1.2 17.9 11.8 0.4 0 0.4 0.4 134 5 130 305 66 0 66 0 -5.2 0 -5.1 -5.6 12/28/2004 17:20:00 14.8 1.3 17.2 10.7 14.4 1.2 17.2 11.5 0.4 0 0.4 0.4 136 6 138 305 66 0 67 0 -5.1 0 -4.7 -5.3 12/28/2004 17:30:00 15.2 1.3 18.3 11.5 14.8 1.3 18.3 11.5 0.4 0 0.4 0.4 136 5 136 305 65 1 65 0 -5 0 -4.7 -5.1 12/28/2004 17:40:00 14.7 1.5 18.3 10.7 14.4 1.4 17.9 9.9 0.4 0 0.4 0.4 138 7 131 305 65 1 65 0 -5 0 -4.5 -5.1 12/28/2004 17:50:00 13.6 1.2 16.8 9.5 13.3 1.2 16.4 9.5 0.4 0 0.4 0.4 137 7 135 305 64 1 63 0 -5 0 -4.7 -5.1 12/28/2004 18:00:00 13.7 1.5 17.6 9.9 13.4 1.4 17.2 9.5 0.4 0 0.4 0.4 138 7 144 305 65 0 65 0 -4.8 0 -4.5 -4.9 12/28/2004 18:10:00 14.3 2.3 20.2 8 14.1 2.1 19.1 9.1 0.4 0 0.4 0.4 145 9 147 305 64 0 65 0 -4.5 0 -4.2 -4.7 12/28/2004 18:20:00 15.1 2 20.6 10.3 14.6 1.7 21.4 11.1 0.4 0 0.4 0.4 146 8 137 305 63 1 62 0 -4.2 0 -4 -4.5 12/28/2004 18:30:00 15.5 1.7 19.5 10.7 15.1 1.6 19.5 11.1 0.4 0 0.4 0.4 146 8 144 305 62 0 62 0 -4.2 0 -4 -4.2 12/28/2004 18:40:00 15.6 1.8 20.6 11.1 15.4 1.7 19.9 10.7 0.4 0 0.4 0.4 147 7 148 305 61 0 61 0 -4.2 0 -4 -4.5 12/28/2004 18:50:00 16.8 1.8 21.4 11.5 16.3 1.6 21.4 10.7 0.4 0 0.4 0.4 147 8 156 305 60 0 60 0 -4.1 0 -4 -4.5 12/28/2004 19:00:00 16.2 1.7 20.6 12.2 16 1.7 20.6 12.2 0.4 0 0.4 0.4 146 8 143 305 60 0 60 0 -4 0 -3.8 -4 12/28/2004 19:10:00 16.9 1.9 21 11.1 16.5 1.8 21 11.5 0.4 0 0.4 0.4 148 7 146 305 59 0 59 0 -3.9 0 -3.6 -4 12/28/2004 19:20:00 16.5 2 21 10.7 16.3 1.8 20.6 11.5 0.4 0 0.4 0.4 148 8 153 305 59 0 59 0 -3.7 0 -3.3 -3.8 12/28/2004 19:30:00 17.4 1.6 20.6 12.6 17.1 1.6 21 12.2 0.4 0 0.4 0.4 149 7 152 305 58 0 59 0 -3.5 0 -3.3 -3.8 12/28/2004 19:40:00 15.7 1.9 21 10.7 15.4 1.8 19.9 10.3 0.4 0 0.4 0.4 149 7 151 305 58 0 59 0 -3.3 0 -2.7 -3.3 12/28/2004 19:50:00 15.4 1.6 19.1 11.1 15.3 1.5 20.2 11.5 0.4 0 0.4 0.4 149 7 152 305 59 0 59 0 -3.3 0 -3.3 -3.6 12/28/2004 20:00:00 15.3 1.8 20.6 9.9 15 1.7 19.5 11.1 0.4 0 0.4 0.4 149 7 151 305 59 0 59 0 -3.3 0 -2.7 -3.3 12/28/2004 20:10:00 14.6 1.9 19.9 9.9 14.7 1.6 19.1 9.5 0.4 0 0.4 0.4 152 8 155 305 59 0 60 0 -2.9 0.1 -2.4 -3.1 12/28/2004 20:20:00 14.2 2 19.1 9.5 15.1 1.5 19.9 11.5 0.4 0 0.4 0.4 157 7 145 305 61 0 60 0 -2.5 0.2 -1.8 -2.7 12/28/2004 20:30:00 15.2 1.9 20.2 10.7 16.9 1.2 19.9 13.3 0.4 0 0.4 0.4 160 5 143 305 63 1 63 0 -1.9 0 -1.3 -2.2 12/28/2004 20:40:00 14.1 1.7 19.1 10.7 16.5 1 19.1 13.7 0.4 0 0.4 0.4 161 5 152 305 65 1 64 0 -1.6 0 -1.3 -1.8 12/28/2004 20:50:00 13.8 1.7 19.1 9.9 16.4 1.2 19.5 13 0.4 0 0.4 0.4 162 5 156 305 68 1 69 0 -1.4 0 -1.1 -1.8 12/28/2004 21:00:00 13.5 1.5 17.6 9.9 16.8 1.5 20.6 13 0.4 0 0.4 0.4 165 5 155 305 70 1 71 0 -1.1 0.1 -0.6 -1.3 12/28/2004 21:10:00 14.1 1.4 19.5 10.7 17.4 1.5 21 12.6 0.4 0 0.4 0.4 166 5 171 305 73 1 76 0 -0.7 0 -0.4 -1.1 12/28/2004 21:20:00 15.5 1.3 19.1 12.6 19.8 1.3 23.7 15.6 0.4 0 0.4 0.4 167 4 170 305 77 1 77 0 -0.4 0 0.1 -0.6 12/28/2004 21:30:00 16 1.5 21 12.6 19.4 1.7 23.7 14.9 0.4 0 0.4 0.4 169 5 174 305 79 0 79 0 -0.3 0 0.1 -0.4 12/28/2004 21:40:00 15.1 1.7 20.2 11.1 17.3 1.3 20.6 13.3 0.4 0 0.4 0.4 173 6 172 305 81 0 81 0 -0.2 0 0.3 -0.4 12/28/2004 21:50:00 16 2.3 21.8 10.7 17.6 1.7 22.1 13 0.4 0 0.4 0.4 176 6 177 305 81 1 81 0 -0.2 0 0.1 -0.4 12/28/2004 22:00:00 16.7 2.2 21.8 11.1 18.1 1.7 22.1 13.3 0.4 0 0.4 0.4 176 5 181 305 81 0 81 0 -0.1 0 0.3 -0.4 12/28/2004 22:10:00 16.3 2 20.6 10.7 17.9 1.7 21.8 13.3 0.4 0 0.4 0.4 177 6 183 305 83 0 82 0 -0.1 0 0.1 -0.1 12/28/2004 22:20:00 16.3 1.6 20.2 12.2 17.9 1.5 21.4 13.7 0.4 0 0.4 0.4 177 5 182 305 84 0 83 0 0 0 0.1 -0.1 12/28/2004 22:30:00 15.7 1.6 19.5 11.5 16.9 1.6 20.2 13.3 0.4 0 0.4 0.4 178 6 184 305 83 0 83 0 0 0 0.1 -0.1 12/28/2004 22:40:00 15.1 1.4 18.7 10.7 15.7 1.5 18.7 12.2 0.4 0 0.4 0.4 180 5 183 305 83 0 82 0 -0.2 0 0.6 -0.4 12/28/2004 22:50:00 15.8 1.6 19.9 10.7 16.3 1.5 20.2 12.2 0.4 0 0.4 0.4 179 5 180 305 83 0 83 0 -0.3 0 0.1 -0.4 12/28/2004 23:00:00 15.7 1.3 19.1 11.1 16.2 1.2 19.5 13 0.4 0 0.4 0.4 180 4 171 305 84 0 84 0 -0.1 0 0.3 -0.4 12/28/2004 23:10:00 15.2 1.4 18.7 11.5 15.6 1.4 19.1 12.2 0.4 0 0.4 0.4 182 4 180 305 84 0 85 0 -0.1 0 0.6 -0.4 12/28/2004 23:20:00 14.9 1.3 17.9 12.2 14.8 1.3 17.9 11.5 0.4 0 0.4 0.4 183 4 183 305 85 0 84 0 -0.1 0 0.3 -0.1 12/28/2004 23:30:00 14.8 1.6 19.5 10.7 14.8 1.5 19.9 11.1 0.4 0 0.4 0.4 184 4 184 305 86 0 87 0 0 0 0.6 -0.1 12/28/2004 23:40:00 14.3 1.3 17.2 10.7 14.5 1.1 17.6 11.1 0.4 0 0.4 0.4 183 4 182 305 88 0 88 0 0 0 0.6 0.1 12/28/2004 23:50:00 15.3 1.3 18.7 11.8 15.5 1.1 19.1 12.2 0.4 0 0.4 0.4 184 4 189 305 88 0 88 0 0 0.1 0.6 0.1 12/29/2004 00:00:00 15.2 1.6 19.1 10.3 15.1 1.4 18.7 11.5 0.4 0 0.4 0.4 184 5 192 305 89 0 89 0 0.1 0 0.6 0.1 12/29/2004 00:10:00 15.5 1.3 19.1 11.8 15.7 1.2 19.5 12.6 0.4 0 0.4 0.4 181 4 192 305 89 0 89 0 0.1 0.1 0.6 0.1 12/29/2004 00:20:00 15 1.3 19.1 11.5 15.4 1.2 19.5 12.2 0.4 0 0.4 0.4 182 4 182 305 89 0 89 0 0.1 0.1 0.6 0.1 12/29/2004 00:30:00 15.5 1.3 19.1 12.2 15.7 1.2 18.7 12.2 0.4 0 0.4 0.4 183 4 183 305 89 0 90 0 0.1 0 0.6 0.1 12/29/2004 00:40:00 17 1.4 20.6 12.6 16.7 1.3 19.9 13 0.4 0 0.4 0.4 186 4 190 305 89 0 90 0 0.2 0 0.6 0.1 12/29/2004 00:50:00 17.8 1.3 21 14.1 17.5 1.4 20.6 14.1 0.4 0 0.4 0.4 186 4 186 305 89 0 90 0 0.3 0 0.8 0.3 12/29/2004 01:00:00 18.5 1.1 21 15.6 18.1 1.2 21 14.9 0.4 0 0.4 0.4 187 3 186 305 89 0 90 0 0.3 0 0.8 0.3 12/29/2004 01:10:00 18.9 1.1 22.6 14.5 18.3 1.3 21.8 14.5 0.4 0 0.4 0.4 188 3 188 305 89 0 90 0 0.3 0 0.8 0.3 12/29/2004 01:20:00 18.6 1.1 21.4 14.9 18.2 1.2 21 15.3 0.4 0 0.4 0.4 187 3 188 305 90 0 90 0 0.2 0 0.6 0.1 12/29/2004 01:30:00 18 1.1 20.6 14.9 17.5 1.3 20.6 13 0.4 0 0.4 0.4 188 3 187 305 90 0 90 0 0.1 0.1 0.6 0.1 12/29/2004 01:40:00 18.1 1.1 21 15.3 17.5 1.2 20.6 13.7 0.4 0 0.4 0.4 189 3 192 305 90 0 90 0 0.1 0.1 0.6 0.1 12/29/2004 01:50:00 18.3 1 21 15.6 17.7 1.3 21 14.1 0.4 0 0.4 0.4 189 3 189 305 90 0 90 0 0.1 0.1 0.6 0.1 12/29/2004 02:00:00 18.1 1.1 21.4 14.5 17.5 1.5 21 12.6 0.4 0 0.4 0.4 189 3 184 305 91 0 91 0 0.1 0.1 0.6 0.1 12/29/2004 02:10:00 18.3 1.2 21.4 14.9 17.6 1.3 20.6 13.3 0.4 0 0.4 0.4 189 3 188 305 91 0 91 0 0.2 0 0.6 0.1 12/29/2004 02:20:00 18.2 1 21 15.6 17.5 1.1 20.2 14.5 0.4 0 0.4 0.4 190 3 191 305 91 0 91 0 0.2 0 0.6 0.1 12/29/2004 02:30:00 18.2 1.1 21 15.3 17.5 1.4 20.2 13.7 0.4 0 0.4 0.4 190 3 192 305 92 0 92 0 0.3 0 0.6 0.1 12/29/2004 02:40:00 17.6 1.1 20.2 14.1 16.7 1.2 19.9 12.6 0.4 0 0.4 0.4 192 3 194 305 92 0 92 0 0.2 0 0.6 0.1 12/29/2004 02:50:00 17.6 1.2 20.6 14.5 16.8 1.4 20.2 12.6 0.4 0 0.4 0.4 192 3 190 305 93 0 93 0 0.2 0 0.6 0.1 12/29/2004 03:00:00 17.8 1.1 21 13.3 16.9 1.3 19.9 11.1 0.4 0 0.4 0.4 192 3 193 305 93 0 93 0 0.2 0 0.6 0.1 12/29/2004 03:10:00 17.5 1.2 19.9 13.7 16.6 1.4 19.9 12.6 0.4 0 0.4 0.4 193 3 191 305 93 0 93 0 0.2 0.1 0.6 0.1 12/29/2004 03:20:00 16.7 1.1 19.5 13.7 15.8 1.3 19.1 12.2 0.4 0 0.4 0.4 194 4 196 305 94 0 93 0 0.2 0.1 0.6 0.1 12/29/2004 03:30:00 17.5 1.2 20.6 14.1 16.5 1.4 19.5 12.6 0.4 0 0.4 0.4 194 3 192 305 94 0 94 0 0.2 0.1 0.6 0.1 12/29/2004 03:40:00 18.4 1 21.4 15.6 17.6 1.3 21 13.3 0.4 0 0.4 0.4 193 3 192 305 94 0 94 0 0.2 0 0.6 0.1 12/29/2004 03:50:00 18 1.2 21 14.5 17 1.3 19.9 13 0.4 0 0.4 0.4 194 4 194 305 94 0 94 0 0.2 0 0.6 0.1 12/29/2004 04:00:00 17.6 1.2 20.6 14.1 16.6 1.4 20.2 12.6 0.4 0 0.4 0.4 193 3 186 305 94 0 94 0 0.2 0 0.6 0.1 12/29/2004 04:10:00 16.6 1.1 19.1 13 15.8 1.3 19.1 11.8 0.4 0 0.4 0.4 195 3 194 305 94 0 94 0 0.2 0.1 0.6 0.1 12/29/2004 04:20:00 16.5 1 19.1 13.3 15.8 1.2 19.1 12.2 0.4 0 0.4 0.4 196 3 195 305 95 0 94 0 0.1 0.1 0.6 0.1 12/29/2004 04:30:00 16.4 1.1 19.1 12.6 15.4 1.3 18.3 11.1 0.4 0 0.4 0.4 195 3 195 305 95 0 95 0 0.1 0.1 0.6 0.1 12/29/2004 04:40:00 16.5 1.1 19.5 13.3 15.8 1.4 19.9 11.8 0.4 0 0.4 0.4 191 3 193 305 95 0 95 0 0.2 0 0.6 0.1 12/29/2004 04:50:00 16.2 1 18.7 13.3 15.6 1.2 18.3 11.8 0.4 0 0.4 0.4 192 4 194 305 95 0 95 0 0.2 0 0.6 0.1 12/29/2004 05:00:00 15.1 0.9 17.2 12.2 14.3 1 17.2 11.5 0.4 0 0.4 0.4 194 3 189 305 96 0 95 0 0.2 0 0.6 0.1 12/29/2004 05:10:00 14.7 0.9 17.2 11.8 14 1 16.4 10.3 0.4 0 0.4 0.4 192 3 190 305 96 0 96 0 0.2 0.1 0.6 0.1 12/29/2004 05:20:00 15.1 1 17.6 12.6 14.5 1.2 17.2 10.3 0.4 0 0.4 0.4 192 3 192 305 96 0 96 0 0.2 0 0.6 0.1 12/29/2004 05:30:00 15.8 1 18.3 12.6 15.1 1.2 18.3 10.7 0.4 0 0.4 0.4 192 3 190 305 97 0 97 0 0.2 0 0.6 0.1 12/29/2004 05:40:00 15.8 1.2 19.5 12.2 15.2 1.3 18.7 11.8 0.4 0 0.4 0.4 191 4 186 305 97 0 97 0 0.2 0 0.6 0.1 12/29/2004 05:50:00 16.3 0.9 18.7 14.1 16 1.1 18.7 13 0.4 0 0.4 0.4 190 3 188 305 98 0 97 0 0.3 0 0.8 0.1 12/29/2004 06:00:00 16.5 1 19.1 13.7 16.4 1.1 19.1 12.6 0.4 0 0.4 0.4 189 3 188 305 98 0 97 0 0.3 0 0.8 0.1 12/29/2004 06:10:00 17.3 1 19.9 14.9 17.4 1.1 21 14.1 0.4 0 0.4 0.4 188 3 188 305 97 0 97 0 0.2 0 0.6 0.1 12/29/2004 06:20:00 17.5 1.1 20.2 14.9 17.4 1.2 20.6 11.8 0.4 0 0.4 0.4 189 3 190 305 97 0 97 0 0.2 0.1 0.6 0.1 12/29/2004 06:30:00 16 1.1 18.7 13.7 15.8 1.3 18.7 12.2 0.4 0 0.4 0.4 190 3 194 305 97 0 97 0 0.1 0.1 0.6 0.1 12/29/2004 06:40:00 15.4 0.9 17.9 13 15.1 1.1 18.7 12.2 0.4 0 0.4 0.4 190 3 192 305 97 0 97 0 0.2 0.1 0.6 0.1 12/29/2004 06:50:00 15.7 1 18.3 13 15.5 1.1 17.9 12.2 0.4 0 0.4 0.4 190 3 186 305 97 0 97 0 0.2 0.1 0.6 0.1 12/29/2004 07:00:00 14.6 1.1 17.6 9.5 14.6 1.3 17.9 9.5 0.4 0 0.4 0.4 188 3 192 305 98 0 98 0 0.2 0 0.6 0.1 12/29/2004 07:10:00 15.3 0.9 17.9 13 15.4 1 18.7 12.6 0.4 0 0.4 0.4 188 3 187 305 98 0 98 0 0.2 0.1 0.6 0.1 12/29/2004 07:20:00 12.7 2 17.2 7.2 13.5 1.5 16.8 9.5 0.4 0 0.4 0.4 184 4 192 305 99 0 98 0 0.2 0.1 0.6 0.1 12/29/2004 07:30:00 9.7 1.6 13 4.9 12.2 1 14.9 9.1 0.4 0 0.4 0.4 179 5 186 305 99 0 99 0 0.2 0.1 0.6 0.1 12/29/2004 07:40:00 10.4 1.5 14.1 6.8 13.2 1 15.6 10.7 0.4 0 0.4 0.4 178 5 174 305 98 0 99 0 0.2 0.1 0.6 0.1 12/29/2004 07:50:00 10.1 1.5 14.5 6.1 13.2 1 15.6 9.5 0.4 0 0.4 0.4 177 5 184 305 99 0 99 0 0.1 0.1 0.6 0.1 12/29/2004 08:00:00 9.3 1.7 13.7 5.3 12.3 1.3 15.3 9.1 0.4 0 0.4 0.4 176 5 183 305 99 0 99 0 0 0 0.6 0.1 12/29/2004 08:10:00 7.9 1.5 11.5 5.3 11.1 1 13.7 8.8 0.4 0 0.4 0.4 174 5 176 305 99 0 99 0 0 0 0.6 0.1 12/29/2004 08:20:00 8.8 1.4 13 5.7 12.6 1.5 16.8 9.5 0.4 0 0.4 0.4 171 6 169 305 98 0 98 0 0 0.1 0.6 0.1 12/29/2004 08:30:00 9.7 1.2 13.7 6.5 15.5 1.2 17.9 11.8 0.4 0 0.4 0.4 169 4 172 305 98 0 98 0 0 0 0.6 0.1 12/29/2004 08:40:00 10.3 1.5 14.9 6.8 15.6 1.3 19.9 12.6 0.4 0 0.4 0.4 170 5 176 305 98 0 98 0 0 0 0.3 0.1 12/29/2004 08:50:00 10.4 1.6 15.3 6.8 15.3 1.5 19.9 11.8 0.4 0 0.4 0.4 170 5 169 305 97 0 96 0 0 0 0.6 0.1 12/29/2004 09:00:00 12 1.6 18.7 8 17 1.2 21.4 13.3 0.4 0 0.4 0.4 169 5 158 305 96 0 96 0 -0.1 0 0.6 -0.4 12/29/2004 09:10:00 10.3 1.4 14.9 6.8 15.4 1.4 18.7 11.5 0.4 0 0.4 0.4 168 4 163 305 97 0 97 0 -0.3 0 0.1 -0.4 12/29/2004 09:20:00 8.6 1 12.2 6.1 13.5 1 16.8 9.9 0.4 0 0.4 0.4 168 4 179 305 97 0 97 0 -0.4 0.1 0.3 -0.6 12/29/2004 09:30:00 8.2 1.1 11.8 5.7 12.8 1 14.9 9.9 0.4 0 0.4 0.4 168 4 162 305 97 0 96 0 -0.5 0.1 0.1 -0.6 12/29/2004 09:40:00 8.6 1.3 12.6 5.7 13.3 1 15.6 10.7 0.4 0 0.4 0.4 167 4 168 305 96 0 96 0 -0.5 0 0.1 -0.8 12/29/2004 09:50:00 9.6 1.5 14.9 6.1 12.9 0.9 14.9 10.3 0.4 0 0.4 0.4 163 4 160 305 96 0 96 0 -0.8 0.1 -0.4 -1.1 12/29/2004 10:00:00 11.1 1.7 14.5 6.1 11.4 1.1 14.1 8.4 0.4 0 0.4 0.4 155 6 155 305 96 0 96 0 -1.1 0 -0.8 -1.3 12/29/2004 10:10:00 12.9 1.2 16.8 9.9 12.4 1.2 16.1 9.5 0.4 0 0.4 0.4 149 4 151 305 97 0 97 0 -1.3 0 -1.1 -1.3 12/29/2004 10:20:00 13.7 1 16.4 9.9 13.2 1.1 16.1 9.9 0.4 0 0.4 0.4 150 3 146 305 97 1 97 0 -1.4 0 -0.8 -1.3 12/29/2004 10:30:00 14.3 1.3 16.8 9.9 13.8 1 16.4 11.1 0.4 0 0.4 0.4 150 5 148 305 97 0 96 0 -1.4 0 -1.1 -1.5 12/29/2004 10:40:00 13 1.8 16.4 7.2 13.1 1.2 16.1 9.1 0.4 0 0.4 0.4 153 7 156 305 97 0 97 0 -1.4 0 -1.1 -1.8 12/29/2004 10:50:00 12.7 1.4 16.1 8.8 12.6 1.2 16.1 9.5 0.4 0 0.4 0.4 147 8 155 305 96 0 96 0 -1.5 0.1 -1.1 -1.8 12/29/2004 11:00:00 13 1.4 16.4 9.1 12.7 1.3 16.1 9.5 0.4 0 0.4 0.4 148 7 152 305 97 0 96 0 -1.6 0.1 -1.1 -1.8 12/29/2004 11:10:00 12.1 1.7 15.6 7.6 12.1 1.3 15.6 8.4 0.4 0 0.4 0.4 152 7 151 305 97 0 97 0 -1.6 0 -1.1 -1.8 12/29/2004 11:20:00 11.6 1.7 16.1 7.2 11.3 1.5 14.9 6.8 0.4 0 0.4 0.4 148 6 149 305 96 0 96 0 -1.6 0 -1.1 -1.8 12/29/2004 11:30:00 9.6 1.2 13.7 6.5 9.4 1.2 13.3 6.8 0.4 0 0.4 0.4 140 8 145 305 96 0 95 0 -1.7 0 -1.1 -1.8 12/29/2004 11:40:00 9.9 1 13 7.2 9.8 1 13 7.2 0.4 0 0.4 0.4 138 6 141 305 96 0 95 0 -1.8 0 -1.3 -2 12/29/2004 11:50:00 8.2 1.2 11.8 4.9 8.1 1.3 12.2 4.6 0.4 0 0.4 0.4 140 9 140 305 94 0 95 0 -1.8 0 -1.3 -2 12/29/2004 12:00:00 8.7 1.6 11.5 4.6 8.8 1.4 11.8 4.9 0.4 0 0.4 0.4 146 11 139 305 94 0 94 0 -1.9 0 -1.3 -2 12/29/2004 12:10:00 10.8 1.1 13.7 7.6 10.4 1 13 8.4 0.4 0 0.4 0.4 146 7 146 305 94 0 94 0 -1.8 0 -1.3 -2 12/29/2004 12:20:00 9.9 1.3 13.3 6.1 9.7 1.2 12.2 6.8 0.4 0 0.4 0.4 144 9 137 305 94 0 94 0 -2 0 -1.5 -2 12/29/2004 12:30:00 8.9 1.8 13 4.6 9.2 1.6 13.3 5.3 0.4 0 0.4 0.4 152 10 142 305 94 0 94 0 -2 0.1 -1.5 -2 12/29/2004 12:40:00 11.2 1.6 15.3 7.2 11 1.6 14.5 6.5 0.4 0 0.4 0.4 142 8 163 305 94 0 93 0 -2.1 0.1 -1.8 -2.4 12/29/2004 12:50:00 11.6 1.3 14.5 7.2 11.4 1.2 14.9 8 0.4 0 0.4 0.4 144 8 136 305 93 0 93 0 -2.2 0.1 -1.8 -2.2 12/29/2004 13:00:00 12.1 1.5 15.3 7.6 12 1.4 14.9 8.4 0.4 0 0.4 0.4 141 8 138 305 93 0 93 0 -2.2 0 -1.8 -2.4 12/29/2004 13:10:00 13.5 1.4 16.8 9.5 13.2 1.3 16.4 9.5 0.4 0 0.4 0.4 136 6 135 305 92 0 92 0 -2.2 0 -1.8 -2.4 12/29/2004 13:20:00 13.6 1 16.4 11.1 13.4 1 16.4 11.1 0.4 0 0.4 0.4 135 4 141 305 92 0 92 0 -2.2 0 -1.8 -2.4 12/29/2004 13:30:00 13.5 1.1 16.8 9.9 13.3 1.1 16.1 10.3 0.4 0 0.4 0.4 135 4 138 305 92 0 93 0 -2.2 0 -1.8 -2.4 12/29/2004 13:40:00 12.4 0.9 14.9 10.3 12.2 0.9 14.5 9.9 0.4 0 0.4 0.4 134 5 138 305 91 1 92 0 -2.3 0 -1.8 -2.4 12/29/2004 13:50:00 12.6 0.9 14.5 9.5 12.3 0.9 14.5 9.5 0.4 0 0.4 0.4 131 5 136 305 89 0 88 0 -2.3 0 -2 -2.4 12/29/2004 14:00:00 11.5 1.2 14.1 8 11.3 1.2 13.7 8 0.4 0 0.4 0.4 131 7 124 305 87 0 88 0 -2.4 0 -2 -2.7 12/29/2004 14:10:00 9.4 1.3 13.3 6.8 9.4 1.3 13 6.1 0.4 0 0.4 0.4 127 14 123 305 86 1 85 0 -2.6 0.1 -2 -2.7 12/29/2004 14:20:00 11.3 2.2 15.3 5.7 11 2.2 15.3 6.1 0.4 0 0.4 0.4 121 10 123 305 84 0 85 0 -2.6 0 -2 -2.7 12/29/2004 14:30:00 11.7 1.9 16.8 7.2 11.5 1.9 16.8 7.6 0.4 0 0.4 0.4 121 10 120 305 84 0 84 0 -2.6 0 -2.2 -2.7 12/29/2004 14:40:00 12 1.9 16.4 7.2 12 1.7 16.4 7.2 0.4 0 0.4 0.4 129 9 128 305 84 0 84 0 -2.7 0 -2.4 -2.7 12/29/2004 14:50:00 13.9 1.8 18.7 9.5 13.6 1.7 18.3 9.5 0.4 0 0.4 0.4 130 7 128 305 83 0 83 0 -2.8 0 -2.4 -2.9 12/29/2004 15:00:00 15.2 1.3 19.1 11.5 14.8 1.2 17.6 11.8 0.4 0 0.4 0.4 132 5 138 305 83 0 83 0 -2.8 0 -2.4 -3.1 12/29/2004 15:10:00 13.5 1.8 18.3 8.8 13.3 1.7 17.9 8.4 0.4 0 0.4 0.4 130 10 126 305 83 0 83 0 -2.9 0 -2.4 -3.1 12/29/2004 15:20:00 14.6 1.6 19.5 10.7 14.4 1.5 18.3 9.5 0.4 0 0.4 0.4 131 7 117 305 81 0 81 0 -3.1 0.1 -2.4 -3.3 12/29/2004 15:30:00 16.2 1.4 20.6 10.7 15.9 1.3 19.5 11.5 0.4 0 0.4 0.4 131 5 134 305 79 1 79 0 -3.3 0 -2.7 -3.3 12/29/2004 15:40:00 15.2 1.3 19.9 11.1 14.8 1.3 19.1 9.9 0.4 0 0.4 0.4 132 6 124 305 78 0 78 0 -3.4 0 -2.9 -3.6 12/29/2004 15:50:00 14.5 1.3 17.6 11.1 14.1 1.2 16.8 11.1 0.4 0 0.4 0.4 133 4 130 305 77 0 77 0 -3.6 0.1 -3.1 -3.8 12/29/2004 16:00:00 14.8 1.1 17.2 11.1 14.4 1.1 16.8 10.7 0.4 0 0.4 0.4 136 5 137 305 76 0 76 0 -3.8 0 -3.3 -4 12/29/2004 16:10:00 15.1 1.3 17.9 10.7 14.8 1.2 17.2 11.1 0.4 0 0.4 0.4 136 5 150 305 74 0 75 0 -4 0 -3.3 -4.2 12/29/2004 16:20:00 15.1 1.2 17.9 11.1 14.7 1.2 17.6 11.5 0.4 0 0.4 0.4 135 5 145 305 73 0 74 0 -4.2 0.1 -3.8 -4.5 12/29/2004 16:30:00 14.7 1.1 18.3 11.1 14.4 1.1 18.3 11.1 0.4 0 0.4 0.4 136 5 140 305 73 0 73 0 -4.3 0 -3.8 -4.5 12/29/2004 16:40:00 14 1.2 16.8 11.1 13.8 1 17.6 11.1 0.4 0 0.4 0.4 135 5 137 305 74 0 74 0 -4.4 0 -3.8 -4.5 12/29/2004 16:50:00 14 1.1 16.1 10.7 13.7 1 16.1 10.7 0.4 0 0.4 0.4 135 4 147 305 74 0 74 0 -4.4 0 -3.8 -4.5 12/29/2004 17:00:00 14.4 1.1 16.4 11.5 13.9 1 16.4 11.1 0.4 0 0.4 0.4 133 5 133 305 74 0 74 0 -4.4 0 -3.8 -4.5 12/29/2004 17:10:00 14.3 0.9 16.4 11.8 14 0.8 16.1 11.8 0.4 0 0.4 0.4 130 4 129 305 74 0 74 0 -4.4 0 -3.8 -4.5 12/29/2004 17:20:00 14.2 1.3 18.3 10.3 13.9 1.3 17.6 10.3 0.4 0 0.4 0.4 131 5 141 305 75 0 74 0 -4.4 0 -4 -4.5 12/29/2004 17:30:00 13.2 1.2 17.2 9.5 12.9 1.2 16.8 9.9 0.4 0 0.4 0.4 132 5 133 305 74 0 74 0 -4.4 0 -4.2 -4.5 12/29/2004 17:40:00 13.2 1.1 15.6 10.3 13 1 15.3 9.5 0.4 0 0.4 0.4 132 5 130 305 76 0 76 0 -4.4 0 -4.2 -4.5 12/29/2004 17:50:00 13.3 1 15.6 10.3 13.1 1 15.6 9.9 0.4 0 0.4 0.4 131 5 124 305 76 0 76 0 -4.4 0 -4.2 -4.5 12/29/2004 18:00:00 13.3 1.1 15.6 9.5 13 1.1 15.6 9.5 0.4 0 0.4 0.4 131 6 140 305 75 0 76 0 -4.3 0.1 -3.8 -4.5 12/29/2004 18:10:00 12.7 1 15.6 9.5 12.4 1 14.9 9.5 0.4 0 0.4 0.4 132 5 131 305 75 0 74 0 -4.3 0 -3.8 -4.5 12/29/2004 18:20:00 12.5 1.1 15.3 9.5 12.2 1 15.3 9.5 0.4 0 0.4 0.4 133 6 143 305 74 0 74 0 -4.3 0.1 -3.8 -4.5 12/29/2004 18:30:00 12.5 1.1 15.3 9.1 12.2 1.1 16.1 9.1 0.4 0 0.4 0.4 132 6 135 305 74 0 74 0 -4.4 0 -4 -4.5 12/29/2004 18:40:00 13.1 1 15.3 9.9 12.8 1 14.9 9.5 0.4 0 0.4 0.4 135 4 130 305 73 0 74 0 -4.4 0 -3.8 -4.5 12/29/2004 18:50:00 12.6 1.1 15.3 9.5 12.4 1.1 15.3 9.5 0.4 0 0.4 0.4 135 4 133 305 73 0 73 0 -4.5 0 -4 -4.7 12/29/2004 19:00:00 13.1 1 15.6 10.7 12.8 1 15.6 9.9 0.4 0 0.4 0.4 135 5 139 305 73 0 73 0 -4.4 0 -4 -4.7 12/29/2004 19:10:00 13.5 1.3 16.1 9.5 13.2 1.2 16.1 10.3 0.4 0 0.4 0.4 136 5 131 305 72 0 72 0 -4.4 0 -4 -4.5 12/29/2004 19:20:00 13.5 1.2 16.4 10.3 13.2 1.1 16.4 9.9 0.4 0 0.4 0.4 135 5 135 305 72 0 72 0 -4.4 0 -4 -4.5 12/29/2004 19:30:00 13.9 1.2 16.4 11.5 13.6 1.2 16.1 9.9 0.4 0 0.4 0.4 137 5 134 305 72 0 72 0 -4.5 0 -4 -4.7 12/29/2004 19:40:00 14.4 1.1 16.8 11.5 14 1.1 16.8 11.5 0.4 0 0.4 0.4 137 4 133 305 71 0 72 0 -4.5 0 -4 -4.7 12/29/2004 19:50:00 14.1 1.1 16.4 10.3 13.8 1 16.1 11.1 0.4 0 0.4 0.4 135 5 137 305 71 0 71 0 -4.6 0.1 -4 -4.7 12/29/2004 20:00:00 14.6 1.3 17.9 10.7 14.2 1.3 16.8 10.7 0.4 0 0.4 0.4 133 5 129 305 70 0 70 0 -4.8 0 -4.7 -4.7 12/29/2004 20:10:00 14.5 1.2 17.6 11.8 14.1 1.1 17.2 11.5 0.4 0 0.4 0.4 131 5 127 305 71 0 71 0 -4.9 0 -4.7 -5.1 12/29/2004 20:20:00 14.1 1.5 17.6 9.1 13.7 1.5 16.8 7.6 0.4 0 0.4 0.4 133 5 133 305 71 0 71 0 -5.1 0 -4.9 -5.1 12/29/2004 20:30:00 13.9 1.7 18.3 8.8 13.6 1.5 16.8 9.1 0.4 0 0.4 0.4 131 6 130 305 73 0 73 0 -5.1 0 -4.7 -5.1 12/29/2004 20:40:00 14.2 1.5 17.6 10.3 13.9 1.5 17.2 9.5 0.4 0 0.4 0.4 133 6 125 305 75 1 76 0 -5 0 -4.9 -5.1 12/29/2004 20:50:00 14.7 1.3 17.9 10.7 14.3 1.3 17.2 11.5 0.4 0 0.4 0.4 134 6 134 305 78 1 77 0 -4.9 0 -4.7 -4.9 12/29/2004 21:00:00 14.7 1.3 17.6 10.7 14.2 1.3 17.6 10.3 0.4 0 0.4 0.4 135 5 141 305 80 0 80 0 -4.8 0.1 -4.5 -4.9 12/29/2004 21:10:00 15.2 1.3 17.6 12.2 14.8 1.2 17.6 11.8 0.4 0 0.4 0.4 135 5 135 305 81 0 82 0 -4.7 0 -4.2 -4.7 12/29/2004 21:20:00 15.2 1 17.6 13 14.7 1 17.2 12.2 0.4 0 0.4 0.4 132 4 134 305 82 0 82 0 -4.8 0.1 -4.5 -4.9 12/29/2004 21:30:00 14.9 1.3 18.7 11.1 14.6 1.2 17.9 11.1 0.4 0 0.4 0.4 132 5 136 305 82 0 82 0 -4.8 0.1 -4.5 -4.9 12/29/2004 21:40:00 14.3 1.5 17.9 9.5 14.1 1.5 18.7 9.1 0.4 0 0.4 0.4 131 9 129 305 81 0 82 0 -5 0 -4.5 -5.1 12/29/2004 21:50:00 12.2 1.7 17.6 8.4 12.2 1.7 18.3 8 0.4 0 0.4 0.4 127 13 132 305 81 0 82 0 -5.1 0 -4.7 -5.1 12/29/2004 22:00:00 12 2.2 17.9 6.8 11.8 2.2 18.3 6.5 0.4 0 0.4 0.4 123 12 116 305 81 0 82 0 -5 0 -4.7 -5.1 12/29/2004 22:10:00 12.4 2.2 17.6 6.5 12.1 2.2 18.3 5.7 0.4 0 0.4 0.4 128 13 130 305 82 0 82 0 -4.9 0 -4.5 -5.1 12/29/2004 22:20:00 13.9 1.8 18.7 8 13.6 1.8 19.1 8 0.4 0 0.4 0.4 129 12 137 305 83 0 83 0 -4.9 0.1 -4.5 -4.9 12/29/2004 22:30:00 14.2 2.4 19.1 8.4 13.9 2.4 18.7 8.4 0.4 0 0.4 0.4 130 11 138 305 83 0 82 0 -4.9 0.1 -4.5 -5.1 12/29/2004 22:40:00 13.4 2.2 18.7 6.8 13.3 2.2 20.2 8.4 0.4 0 0.4 0.4 129 14 124 305 82 0 82 0 -4.9 0 -4.5 -5.1 12/29/2004 22:50:00 13.9 2.3 21 9.5 13.6 2.4 20.6 7.2 0.4 0 0.4 0.4 126 13 137 305 82 0 82 0 -5 0 -4.7 -5.1 12/29/2004 23:00:00 12.8 2 18.7 7.2 12.6 2.1 19.1 7.6 0.4 0 0.4 0.4 126 13 129 305 83 0 82 0 -4.9 0 -4.5 -5.1 12/29/2004 23:10:00 13.4 2.1 19.5 6.8 13.1 2.2 19.9 5.3 0.4 0 0.4 0.4 125 13 106 305 83 0 84 0 -4.9 0.1 -4.5 -4.9 12/29/2004 23:20:00 13.9 2.1 19.9 9.1 13.5 2.1 19.9 8 0.4 0 0.4 0.4 127 14 119 305 84 0 84 0 -4.8 0.1 -4.5 -4.9 12/29/2004 23:30:00 14 2.4 21 8.8 13.6 2.4 21.8 8.8 0.4 0 0.4 0.4 120 13 107 305 84 0 84 0 -4.7 0 -4.2 -4.7 12/29/2004 23:40:00 15.3 2.3 21.4 8.8 15.1 2.3 21 9.1 0.4 0 0.4 0.4 125 14 113 305 85 0 85 0 -4.5 0 -4 -4.7 12/29/2004 23:50:00 16.1 2.3 21.4 8 15.8 2.4 22.6 6.5 0.4 0 0.4 0.4 125 14 129 305 84 0 85 0 -4.6 0 -4 -4.7 12/30/2004 00:00:00 16.1 2.4 23.7 10.7 15.9 2.4 23.3 9.1 0.4 0 0.4 0.4 125 13 149 305 84 0 85 0 -4.5 0 -4 -4.7 12/30/2004 00:10:00 15.9 2.1 21.4 9.9 15.7 2.1 20.6 9.9 0.4 0 0.4 0.4 126 13 117 305 85 0 85 0 -4.4 0 -4 -4.5 12/30/2004 00:20:00 15.8 2.1 20.6 9.5 15.6 2.3 21 8.8 0.4 0 0.4 0.4 131 12 110 305 85 0 85 0 -4.4 0 -3.8 -4.5 12/30/2004 00:30:00 15.1 2.2 19.9 7.2 14.8 2.3 19.9 7.2 0.4 0 0.4 0.4 127 11 138 305 85 0 85 0 -4.4 0 -4 -4.7 12/30/2004 00:40:00 15.9 2.1 22.6 10.7 15.9 1.9 21.4 11.8 0.4 0 0.4 0.4 129 13 144 305 85 0 85 0 -4.4 0 -4 -4.7 12/30/2004 00:50:00 16 2.3 23.3 8.8 15.9 2.3 23.3 9.5 0.4 0 0.4 0.4 132 10 121 305 85 0 86 0 -4.4 0 -4 -4.5 12/30/2004 01:00:00 16.2 1.8 22.1 11.1 15.8 1.7 21.4 11.1 0.4 0 0.4 0.4 131 9 127 305 86 0 86 0 -4.4 0.1 -3.8 -4.5 12/30/2004 01:10:00 15.3 1.7 19.9 11.1 15 1.7 20.2 10.7 0.4 0 0.4 0.4 132 7 128 305 86 0 86 0 -4.2 0 -3.8 -4.5 12/30/2004 01:20:00 13.9 2.3 19.1 7.2 13.7 2.3 19.5 7.6 0.4 0 0.4 0.4 127 13 119 305 86 0 86 0 -4.1 0 -3.8 -4.2 12/30/2004 01:30:00 14.1 2.2 20.2 8.8 13.8 2 19.5 8.8 0.4 0 0.4 0.4 129 13 119 305 86 0 86 0 -4.1 0 -3.8 -4.2 12/30/2004 01:40:00 14.2 2.2 20.2 9.5 13.8 2.2 19.5 8 0.4 0 0.4 0.4 127 13 127 305 86 0 86 0 -4.1 0 -3.8 -4.2 12/30/2004 01:50:00 13.7 2.4 20.2 7.6 13.4 2.4 21.8 8 0.4 0 0.4 0.4 126 15 108 305 86 0 86 0 -4.2 0 -3.8 -4.2 12/30/2004 02:00:00 13.3 2.4 19.9 6.8 13.1 2.4 18.3 6.8 0.4 0 0.4 0.4 125 13 145 305 86 0 87 0 -4.1 0 -3.8 -4.2 12/30/2004 02:10:00 13.7 2.4 20.6 8.4 13.7 2.4 21 8 0.4 0 0.4 0.4 128 13 141 305 86 0 86 0 -3.9 0 -3.3 -4 12/30/2004 02:20:00 13.1 2.3 19.1 7.2 12.9 2.3 20.2 8 0.4 0 0.4 0.4 128 15 119 305 87 0 86 0 -3.8 0 -3.3 -3.8 12/30/2004 02:30:00 12.6 2.3 17.9 7.6 12.5 2.4 18.7 7.2 0.4 0 0.4 0.4 127 16 122 305 87 0 87 0 -3.7 0 -3.3 -3.8 12/30/2004 02:40:00 13.4 2.5 21 7.2 13.3 2.5 21.4 8 0.4 0 0.4 0.4 130 15 139 305 86 0 86 0 -3.5 0 -3.1 -3.8 12/30/2004 02:50:00 14.6 2.5 22.6 8.8 14.6 2.4 21.4 7.6 0.4 0 0.4 0.4 132 13 130 305 87 0 87 0 -3.3 0 -2.9 -3.3 12/30/2004 03:00:00 13.4 2.3 21.4 8.4 13.2 2.3 20.6 8.4 0.4 0 0.4 0.4 127 13 137 305 87 0 87 0 -3.2 0 -2.9 -3.3 12/30/2004 03:10:00 12.4 2.1 17.9 7.2 12.2 2 17.6 7.2 0.4 0 0.4 0.4 128 15 129 305 87 0 87 0 -3.1 0 -3.1 -3.3 12/30/2004 03:20:00 13.9 2.2 20.6 8.4 13.7 2.3 21.4 7.6 0.4 0 0.4 0.4 131 13 135 305 87 0 87 0 -3.2 0.1 -2.7 -3.3 12/30/2004 03:30:00 14.1 2.1 21 8 13.8 2 19.1 9.1 0.4 0 0.4 0.4 130 15 159 305 87 0 87 0 -3.2 0 -2.7 -3.3 12/30/2004 03:40:00 13.3 2.7 20.6 7.6 13 2.7 22.1 7.6 0.4 0 0.4 0.4 129 17 136 305 88 0 87 0 -3.1 0 -2.7 -3.3 12/30/2004 03:50:00 13.2 2.5 19.9 5.7 13 2.4 19.1 6.5 0.4 0 0.4 0.4 126 15 126 305 87 0 87 0 -3.1 0 -3.1 -3.3 12/30/2004 04:00:00 13 2.3 19.1 8 12.7 2.2 18.7 7.6 0.4 0 0.4 0.4 126 15 119 305 87 0 87 0 -3.1 0 -2.7 -3.1 12/30/2004 04:10:00 14.5 2.5 21.8 8 14 2.5 21 8 0.4 0 0.4 0.4 128 14 127 305 87 0 87 0 -3.1 0.1 -2.7 -3.3 12/30/2004 04:20:00 13.9 2.4 21.4 8.8 13.6 2.5 21 8.4 0.4 0 0.4 0.4 131 14 151 305 87 0 87 0 -3.2 0 -2.7 -3.3 12/30/2004 04:30:00 14.5 2.4 21.8 9.1 14.2 2.5 20.6 7.6 0.4 0 0.4 0.4 129 15 143 305 87 0 87 0 -3.2 0 -2.7 -3.3 12/30/2004 04:40:00 14.1 2.3 21 8 13.7 2.3 20.6 8.4 0.4 0 0.4 0.4 128 14 140 305 87 0 87 0 -3.1 0 -2.7 -3.3 12/30/2004 04:50:00 14 2.5 21 7.2 13.8 2.4 20.2 7.6 0.4 0 0.4 0.4 129 15 133 305 87 0 87 0 -3 0 -2.4 -3.1 12/30/2004 05:00:00 14.4 2.3 21.4 8.8 14.1 2.4 20.6 8 0.4 0 0.4 0.4 130 13 124 305 87 0 87 0 -2.8 0 -2.7 -3.1 12/30/2004 05:10:00 14.9 2.5 21.8 8.8 14.6 2.4 20.2 8.8 0.4 0 0.4 0.4 132 12 136 305 87 0 87 0 -2.8 0 -2.7 -2.9 12/30/2004 05:20:00 14.2 2.2 19.5 8.8 14.1 2.3 19.1 8.4 0.4 0 0.4 0.4 133 12 140 305 87 0 87 0 -2.7 0.1 -2.4 -2.7 12/30/2004 05:30:00 14.7 2.1 20.6 8.8 14.4 2.1 20.6 9.1 0.4 0 0.4 0.4 132 11 138 305 87 0 87 0 -2.4 0 -2.2 -2.7 12/30/2004 05:40:00 15.7 2.2 21.8 9.9 15.1 2.2 21 8.8 0.4 0 0.4 0.4 134 8 133 305 85 0 85 0 -2.2 0 -2 -2.4 12/30/2004 05:50:00 14.9 1.9 20.2 6.8 14.3 2.1 19.9 7.6 0.4 0 0.4 0.4 132 10 140 305 85 0 84 0 -2 0 -1.8 -2.2 12/30/2004 06:00:00 15.9 1.7 21 10.7 15.2 1.7 20.2 10.3 0.4 0 0.4 0.4 132 8 134 305 84 0 84 0 -1.8 0 -1.3 -2 12/30/2004 06:10:00 15.3 1.6 19.1 10.7 14.7 1.6 19.1 10.3 0.4 0 0.4 0.4 133 7 136 305 84 0 84 0 -1.8 0 -1.3 -2 12/30/2004 06:20:00 15.6 1.5 18.7 10.7 15 1.5 18.7 10.7 0.4 0 0.4 0.4 133 6 134 305 83 0 84 0 -1.7 0 -1.8 -1.8 12/30/2004 06:30:00 14.4 1.6 18.3 9.1 13.8 1.5 17.6 10.3 0.4 0 0.4 0.4 132 6 140 305 84 0 84 0 -1.7 0 -1.3 -1.8 12/30/2004 06:40:00 14.9 1.7 18.3 9.1 14.3 1.6 18.3 9.1 0.4 0 0.4 0.4 132 6 124 305 85 0 84 0 -1.6 0 -1.1 -1.8 12/30/2004 06:50:00 14.6 1.3 19.5 11.5 14.1 1.3 18.7 10.7 0.4 0 0.4 0.4 134 6 137 305 86 0 86 0 -1.4 0 -1.3 -1.5 12/30/2004 07:00:00 14.7 1.4 18.3 10.7 14.4 1.3 18.3 10.7 0.4 0 0.4 0.4 135 6 135 305 88 0 87 0 -1.2 0 -1.1 -1.3 12/30/2004 07:10:00 14.6 1.4 18.7 10.7 14.2 1.3 18.7 10.7 0.4 0 0.4 0.4 135 6 132 305 89 1 91 0 -1.1 0 -0.6 -1.3 12/30/2004 07:20:00 13.7 1.6 17.9 9.1 13.4 1.6 17.6 9.1 0.4 0 0.4 0.4 136 8 133 305 93 1 94 0 -1.1 0 -0.8 -1.1 12/30/2004 07:30:00 13.1 1.6 16.8 8.8 12.7 1.7 17.2 8 0.4 0 0.4 0.4 136 11 130 305 95 0 95 0 -1 0 -0.8 -1.1 12/30/2004 07:40:00 13.5 2 18.3 9.1 13.2 1.8 18.7 8.8 0.4 0 0.4 0.4 139 9 132 305 95 0 95 0 -1 0 -0.8 -1.1 12/30/2004 07:50:00 12.8 1.7 17.2 7.6 12.7 1.6 17.2 8.4 0.4 0 0.4 0.4 141 10 142 305 95 0 95 0 -0.8 0 -0.4 -1.1 12/30/2004 08:00:00 13.2 1.8 17.6 8 13.1 1.7 18.3 8 0.4 0 0.4 0.4 142 9 136 305 97 0 96 0 -0.8 0 -0.4 -1.1 12/30/2004 08:10:00 13.2 1.8 18.7 9.1 12.9 1.7 17.9 8.8 0.4 0 0.4 0.4 141 11 143 305 97 0 97 0 -0.8 0 -0.4 -1.1 12/30/2004 08:20:00 13.9 1.7 18.7 8.8 13.6 1.7 17.6 9.1 0.4 0 0.4 0.4 144 9 144 305 99 0 98 0 -0.7 0 -0.4 -1.1 12/30/2004 08:30:00 14.6 1.7 18.7 9.1 14.2 1.6 18.7 9.1 0.4 0 0.4 0.4 146 9 150 305 100 0 100 0 -0.7 0 -0.4 -0.8 12/30/2004 08:40:00 13.9 2 19.9 8.8 13.8 1.8 17.9 9.1 0.4 0 0.4 0.4 145 10 144 305 99 0 99 0 -0.6 0 0.1 -0.6 12/30/2004 08:50:00 14 1.7 19.9 9.1 13.7 1.7 18.3 9.9 0.4 0 0.4 0.4 145 8 148 305 99 0 100 0 -0.5 0 -0.1 -0.6 12/30/2004 09:00:00 14 1.7 19.5 9.1 13.5 1.7 19.1 9.1 0.4 0 0.4 0.4 146 8 147 305 101 0 101 0 -0.5 0 -0.1 -0.6 12/30/2004 09:10:00 13.4 1.7 17.6 8.8 13.1 1.7 17.2 8.8 0.4 0 0.4 0.4 147 9 152 305 102 0 102 0 -0.5 0 0.1 -0.6 12/30/2004 09:20:00 13.3 1.7 19.1 8.8 13.1 1.5 18.3 9.1 0.4 0 0.4 0.4 147 9 144 305 103 1 104 0 -0.4 0.1 0.1 -0.6 12/30/2004 09:30:00 14.1 1.8 19.5 9.5 13.8 1.7 19.1 9.9 0.4 0 0.4 0.4 147 8 147 305 105 1 104 0 -0.4 0 -0.4 -0.4 12/30/2004 09:40:00 13.1 2.2 18.7 7.2 13.2 1.8 18.3 8.8 0.4 0 0.4 0.4 150 10 145 305 107 0 107 0 -0.3 0 -0.1 -0.4 12/30/2004 09:50:00 13.3 2.1 18.7 8.4 13.4 1.7 19.1 8.8 0.4 0 0.4 0.4 151 9 154 305 109 1 107 0 -0.3 0 -0.1 -0.4 12/30/2004 10:00:00 12.1 2 16.8 7.6 12.7 1.5 18.3 8.8 0.4 0 0.4 0.4 154 10 152 305 109 2 107 0 -0.1 0 0.3 -0.4 12/30/2004 10:10:00 12.3 1.9 17.9 8 13.9 1.7 17.9 8.8 0.4 0 0.4 0.4 161 8 162 305 111 2 112 0 -0.1 0 0.6 -0.1 12/30/2004 10:20:00 12.6 1.6 16.1 8.8 14.6 1.2 18.7 11.5 0.4 0 0.4 0.4 162 5 156 305 117 7 110 0 0 0 0.6 0.1 12/30/2004 10:30:00 11.6 1.7 16.4 8 13.9 1 16.4 10.7 0.4 0 0.4 0.4 162 5 157 305 121 3 124 0 0 0 0.6 0.1 12/30/2004 10:40:00 11.8 1.5 16.1 8.4 13.9 1.1 16.4 11.5 0.4 0 0.4 0.4 163 5 155 305 116 2 117 0 0.1 0.1 0.6 0.1 12/30/2004 10:50:00 11.3 1.3 14.9 8.4 13.8 1.1 16.8 9.9 0.4 0 0.4 0.4 165 6 159 305 119 3 117 0 0.1 0.1 0.6 0.1 12/30/2004 11:00:00 11.5 1.3 14.9 6.5 14.1 1.1 16.8 11.5 0.4 0 0.4 0.4 170 5 169 305 122 4 121 0 0.2 0 0.6 0.1 12/30/2004 11:10:00 11.7 1.7 16.8 7.6 13.2 1.1 16.4 10.3 0.4 0 0.4 0.4 177 7 186 305 108 2 112 0 0.3 0 0.3 0.1 12/30/2004 11:20:00 13.2 1 15.3 10.3 13.4 1 15.6 11.1 0.4 0 0.4 0.4 185 4 179 305 109 1 108 0 0.3 0 0.8 0.1 12/30/2004 11:30:00 13.7 0.9 16.4 11.1 13.3 1.1 16.4 9.9 0.4 0 0.4 0.4 190 4 189 305 111 0 111 0 0.2 0.1 0.8 0.1 12/30/2004 11:40:00 13.7 0.8 16.1 11.5 13.1 0.9 15.3 9.9 0.4 0 0.4 0.4 196 3 189 305 113 1 112 0 0 0 0.6 -0.1 12/30/2004 11:50:00 13.1 0.7 14.9 11.1 12.6 0.8 14.1 10.3 0.4 0 0.4 0.4 200 3 198 305 118 1 116 0 -0.1 0 0.3 -0.4 12/30/2004 12:00:00 12.1 0.7 14.5 9.9 11.6 0.8 13.7 8.4 0.4 0 0.4 0.4 200 3 203 305 121 1 120 0 -0.3 0 0.3 -0.4 12/30/2004 12:10:00 12 0.6 14.1 10.3 11.7 0.7 13.7 9.5 0.4 0 0.4 0.4 202 3 201 305 123 0 123 0 -0.4 0.1 0.1 -0.4 12/30/2004 12:20:00 13 0.9 15.3 10.7 12.5 1 14.9 9.1 0.4 0 0.4 0.4 206 4 210 305 123 0 123 0 -0.4 0.1 0.1 -0.6 12/30/2004 12:30:00 14 0.8 16.4 11.8 13.5 1 16.1 9.9 0.4 0 0.4 0.4 208 3 207 305 125 0 125 0 -0.5 0.1 0.1 -0.6 12/30/2004 12:40:00 14.1 0.8 16.4 11.8 13.3 1.1 15.6 9.5 0.4 0 0.4 0.4 210 4 208 305 126 0 126 0 -0.5 0 0.1 -0.6 12/30/2004 12:50:00 14.1 0.9 16.4 10.7 13 1.1 15.6 9.9 0.4 0 0.4 0.4 212 4 215 305 127 1 126 0 -0.6 0 0.1 -0.6 12/30/2004 13:00:00 14.2 1 16.8 11.5 13.4 1.2 16.4 10.7 0.4 0 0.4 0.4 212 4 211 305 127 1 126 0 -0.7 0 -0.1 -0.8 12/30/2004 13:10:00 14.9 1.1 17.2 9.9 13.6 1.4 16.8 9.5 0.4 0 0.4 0.4 212 4 215 305 128 0 128 0 -0.7 0 -0.1 -0.8 12/30/2004 13:20:00 15.2 1.1 17.6 11.8 14 1.4 17.2 9.9 0.4 0 0.4 0.4 213 4 216 305 128 0 127 0 -0.8 0 -0.4 -1.1 12/30/2004 13:30:00 14.7 1.1 17.6 11.5 13.6 1.5 17.9 8.8 0.4 0 0.4 0.4 214 4 213 305 126 0 126 0 -0.9 0 -0.4 -1.1 12/30/2004 13:40:00 14.7 1 16.8 11.8 13.9 1.3 17.2 10.3 0.4 0 0.4 0.4 215 4 217 305 125 1 126 0 -0.9 0 -0.4 -1.1 12/30/2004 13:50:00 14.5 1 17.2 11.1 14 1.2 16.8 10.7 0.4 0 0.4 0.4 218 4 206 305 123 0 124 0 -0.9 0 -0.6 -1.1 12/30/2004 14:00:00 14.4 1.2 17.6 11.5 13.9 1.3 17.6 9.5 0.4 0 0.4 0.4 217 5 215 305 123 0 124 0 -0.9 0 -0.4 -1.1 12/30/2004 14:10:00 13.9 0.9 16.1 11.8 13 1.2 16.1 9.9 0.4 0 0.4 0.4 215 4 221 305 124 0 124 0 -0.9 0 -0.6 -1.1 12/30/2004 14:20:00 13 1.2 15.6 9.9 12.5 1.4 16.1 9.1 0.4 0 0.4 0.4 219 3 218 305 124 0 124 0 -0.8 0 -0.4 -1.1 12/30/2004 14:30:00 13.6 1.2 16.4 10.7 13.1 1.3 16.8 9.1 0.4 0 0.4 0.4 221 0 221 305 127 1 127 0 -0.7 0 -0.6 -0.8 12/30/2004 14:40:00 12.4 1 15.3 9.1 11.7 1.2 14.9 7.6 0.4 0 0.4 0.4 221 0 221 305 129 0 128 0 -0.7 0 -0.1 -0.8 12/30/2004 14:50:00 11.9 0.7 13.7 8.8 11.3 1 13.7 8 0.4 0 0.4 0.4 221 0 221 305 130 0 130 0 -0.6 0 -0.6 -0.6 12/30/2004 15:00:00 11.9 1 14.5 8.8 11.2 1.2 14.5 8 0.4 0 0.4 0.4 221 0 221 305 130 0 130 0 -0.6 0 0.1 -0.6 12/30/2004 15:10:00 12.2 1.2 15.3 9.5 11.5 1.5 15.3 7.6 0.4 0 0.4 0.4 221 0 221 305 131 0 131 0 -0.6 0 -0.4 -0.6 12/30/2004 15:20:00 12 1 14.5 8.8 11.2 1.2 14.1 7.6 0.4 0 0.4 0.4 221 0 221 305 132 0 131 0 -0.7 0 -0.1 -0.8 12/30/2004 15:30:00 12.8 0.9 15.3 9.9 12.4 1.2 15.3 9.1 0.4 0 0.4 0.4 221 0 221 305 132 0 132 0 -0.8 0 -0.6 -0.8 12/30/2004 15:40:00 12.2 1 14.9 9.1 11.5 1.1 14.9 8.8 0.4 0 0.4 0.4 221 0 221 305 132 0 132 0 -0.7 0 -0.4 -0.8 12/30/2004 15:50:00 12 1.3 14.9 8.8 11.3 1.3 14.9 8 0.4 0 0.4 0.4 221 0 221 305 133 0 133 0 -0.6 0 -0.6 -0.6 12/30/2004 16:00:00 12.9 1.7 17.9 9.1 12 1.5 15.6 8.8 0.4 0 0.4 0.4 221 0 222 305 132 0 132 0 -0.5 0.1 0.1 -0.6 12/30/2004 16:10:00 13.6 1.3 16.8 9.9 12.8 1.3 16.1 8.8 0.4 0 0.4 0.4 222 0 221 305 131 0 132 0 -0.5 0 0.1 -0.6 12/30/2004 16:20:00 12.2 1 14.1 9.1 11.5 1.1 14.5 8.4 0.4 0 0.4 0.4 222 0 222 305 130 0 130 0 -0.7 0 0.1 -1.1 12/30/2004 16:30:00 11.5 0.8 13.3 9.1 10.7 1 13.3 8 0.4 0 0.4 0.4 222 0 221 305 130 0 130 0 -1 0.1 -0.4 -1.1 12/30/2004 16:40:00 11.9 0.7 13.7 9.5 11.5 0.9 13.3 8.8 0.4 0 0.4 0.4 222 0 221 305 130 1 129 0 -1.1 0 -0.6 -1.3 12/30/2004 16:50:00 11.9 0.7 13.7 9.5 11.3 0.9 13.3 8.4 0.4 0 0.4 0.4 221 0 221 305 128 1 128 0 -1.2 0 -0.6 -1.3 12/30/2004 17:00:00 11.6 0.8 13.3 9.1 10.7 1 13 7.6 0.4 0 0.4 0.4 221 0 221 305 126 0 127 0 -1.4 0 -0.8 -1.5 12/30/2004 17:10:00 11.5 0.8 13 8.8 10.6 1 13 8 0.4 0 0.4 0.4 221 0 221 305 126 0 126 0 -1.4 0 -1.1 -1.5 12/30/2004 17:20:00 11.4 0.7 13.3 9.1 10.6 0.9 13 7.2 0.4 0 0.4 0.4 221 0 221 305 126 0 126 0 -1.5 0 -1.1 -1.8 12/30/2004 17:30:00 11.2 0.7 12.6 8.8 10.2 0.9 12.2 7.6 0.4 0 0.4 0.4 221 0 221 305 126 0 126 0 -1.5 0 -1.1 -1.8 12/30/2004 17:40:00 10.6 0.6 12.6 8.4 9.6 0.8 11.8 7.6 0.4 0 0.4 0.4 221 0 221 305 125 0 124 0 -1.6 0 -1.3 -1.8 12/30/2004 17:50:00 10.7 0.6 13 8.4 9.9 0.9 12.2 7.2 0.4 0 0.4 0.4 221 0 221 305 124 0 124 0 -1.6 0 -1.3 -1.8 12/30/2004 18:00:00 10.7 0.7 13 8 9.7 0.8 12.6 7.2 0.4 0 0.4 0.4 221 0 221 305 124 0 124 0 -1.6 0 -1.1 -1.8 12/30/2004 18:10:00 10.8 0.6 12.6 9.5 10.2 0.7 11.8 8 0.4 0 0.4 0.4 221 0 221 305 123 0 123 0 -1.7 0 -1.8 -1.8 12/30/2004 18:20:00 11.2 0.6 13 9.9 10.7 0.5 12.6 9.1 0.4 0 0.4 0.4 221 0 221 305 123 0 123 0 -1.8 0 -1.8 -2 12/30/2004 18:30:00 11.4 0.6 13 9.9 10.9 0.6 13 8.8 0.4 0 0.4 0.4 221 0 221 305 122 1 121 0 -1.9 0 -1.8 -2 12/30/2004 18:40:00 11.3 0.5 13 9.5 10.9 0.6 12.2 8.8 0.4 0 0.4 0.4 221 0 221 305 120 0 121 0 -2 0 -1.5 -2 12/30/2004 18:50:00 12.2 0.6 13.7 9.9 11.9 0.6 13.3 9.9 0.4 0 0.4 0.4 221 0 221 305 119 0 119 0 -2 0 -2 -2.2 12/30/2004 19:00:00 12.1 0.5 13.3 10.7 11.7 0.6 13 9.1 0.4 0 0.4 0.4 221 0 221 305 118 0 119 0 -2 0 -1.5 -2 12/30/2004 19:10:00 10.9 0.7 12.6 9.1 10.4 0.6 12.2 8 0.4 0 0.4 0.4 221 0 221 305 116 1 117 0 -2.2 0.1 -1.5 -2.4 12/30/2004 19:20:00 10.4 0.6 11.8 8.8 10.7 0.8 12.2 7.2 0.4 0 0.4 0.4 221 0 221 305 112 0 112 0 -2.6 0 -2 -2.7 12/30/2004 19:30:00 10.6 0.5 12.2 9.1 11.1 0.5 12.6 9.9 0.4 0 0.4 0.4 221 0 221 305 109 0 109 0 -2.8 0 -2.7 -2.9 12/30/2004 19:40:00 10.2 0.5 12.6 9.1 10.2 0.7 12.2 8 0.4 0 0.4 0.4 221 0 221 305 111 1 113 0 -2.6 0.1 -2.4 -2.9 12/30/2004 19:50:00 11.3 0.6 13 9.1 10.8 0.6 12.6 9.1 0.4 0 0.4 0.4 221 0 221 305 114 1 113 0 -2.4 0 -2.2 -2.7 12/30/2004 20:00:00 10.3 0.7 12.2 8.8 10 0.7 11.8 7.6 0.4 0 0.4 0.4 221 0 221 305 113 1 114 0 -2.5 0.1 -2 -2.7 12/30/2004 20:10:00 10.3 0.7 11.8 7.6 10.2 0.8 12.2 7.2 0.4 0 0.4 0.4 221 0 221 305 111 0 111 0 -2.7 0.1 -2.2 -2.7 12/30/2004 20:20:00 9.7 0.9 12.2 7.2 9.8 1 12.6 6.8 0.4 0 0.4 0.4 221 0 221 305 110 1 111 0 -2.7 0.1 -2 -2.7 12/30/2004 20:30:00 10 0.6 11.5 8.4 9.8 0.6 11.8 8.4 0.4 0 0.4 0.4 221 0 221 305 110 0 109 0 -2.7 0.1 -2.2 -2.7 12/30/2004 20:40:00 10.3 0.5 11.8 8.8 9.9 0.5 11.8 8.8 0.4 0 0.4 0.4 221 0 221 305 110 0 109 0 -2.6 0 -2.2 -2.7 12/30/2004 20:50:00 10.1 0.4 11.1 9.1 9.8 0.5 11.1 8.4 0.4 0 0.4 0.4 221 0 221 305 109 1 109 0 -2.6 0.1 -2.2 -2.7 12/30/2004 21:00:00 9.8 0.6 11.5 8.4 9.6 0.6 10.7 7.6 0.4 0 0.4 0.4 221 0 221 305 103 3 107 0 -2.7 0 -2.4 -2.9 12/30/2004 21:10:00 9.1 0.5 10.7 7.2 9.3 0.6 10.7 6.5 0.4 0 0.4 0.4 221 0 221 305 99 1 99 0 -2.7 0 -2.7 -2.9 12/30/2004 21:20:00 8.6 0.8 10.7 6.5 8.4 1 10.7 5.3 0.4 0 0.4 0.4 221 0 221 305 100 0 99 0 -2.7 0 -2.4 -2.7 12/30/2004 21:30:00 8.1 0.5 9.9 6.1 8 0.8 10.3 6.1 0.4 0 0.4 0.4 221 0 221 305 98 1 99 0 -2.8 0 -2.7 -2.9 12/30/2004 21:40:00 8.2 0.6 9.5 6.8 7.9 0.7 9.5 5.3 0.4 0 0.4 0.4 221 0 221 305 98 0 98 0 -2.8 0 -2.7 -2.9 12/30/2004 21:50:00 8.6 0.7 9.9 6.1 8.8 0.8 10.3 6.1 0.4 0 0.4 0.4 221 0 221 305 98 0 98 0 -2.7 0 -2.7 -2.7 12/30/2004 22:00:00 8.3 0.5 9.5 6.8 8.3 0.5 9.5 6.1 0.4 0 0.4 0.4 221 0 221 305 98 0 98 0 -2.7 0 -2.7 -2.7 12/30/2004 22:10:00 8.4 0.5 9.9 6.8 8.4 0.7 10.3 6.1 0.4 0 0.4 0.4 221 0 221 305 98 0 97 0 -2.8 0 -2.7 -2.9 12/30/2004 22:20:00 8.8 0.5 10.3 7.2 9 0.6 11.1 6.5 0.4 0 0.4 0.4 221 0 221 305 99 1 100 0 -2.6 0 -2.4 -2.7 12/30/2004 22:30:00 8.6 0.5 10.3 7.6 8.9 0.4 10.3 7.6 0.4 0 0.4 0.4 214 13 221 305 101 0 101 0 -2.6 0 -2.4 -2.7 12/30/2004 22:40:00 8.4 0.5 9.5 7.2 8.8 0.5 10.3 7.6 0.4 0 0.4 0.4 191 4 188 305 101 0 101 0 -2.6 0 -2.2 -2.7 12/30/2004 22:50:00 8.6 0.5 10.7 6.8 9.1 0.5 10.3 8 0.4 0 0.4 0.4 189 4 197 305 101 0 101 0 -2.5 0 -2.4 -2.7 12/30/2004 23:00:00 8.1 0.7 10.3 5.7 8.1 0.8 10.7 5.7 0.4 0 0.4 0.4 191 6 197 305 101 0 101 0 -2.4 0 -1.8 -2.7 12/30/2004 23:10:00 8.4 0.7 10.3 6.5 8.2 0.8 10.7 6.1 0.4 0 0.4 0.4 192 5 202 305 102 0 102 0 -2.4 0 -2 -2.7 12/30/2004 23:20:00 8.4 0.4 9.5 7.2 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 195 3 193 305 102 0 102 0 -2.4 0 -2 -2.7 12/30/2004 23:30:00 8 0.5 9.9 6.8 7.6 0.4 9.1 6.5 0.4 0 0.4 0.4 199 4 195 305 100 1 101 0 -2.6 0.1 -2 -2.7 12/30/2004 23:40:00 7.6 0.4 8.8 6.1 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 196 4 198 305 99 0 98 0 -2.7 0 -2.4 -2.7 12/30/2004 23:50:00 7.7 0.8 9.5 5.7 7.8 1 9.9 5.3 0.4 0 0.4 0.4 188 5 194 305 100 0 99 0 -2.5 0 -2.2 -2.7 12/31/2004 00:00:00 8.1 0.4 9.1 6.5 8.3 0.4 9.9 6.5 0.4 0 0.4 0.4 192 4 193 305 99 0 99 0 -2.5 0 -2 -2.7 12/31/2004 00:10:00 6.9 0.8 9.5 4.9 7 1 9.1 4.6 0.4 0 0.4 0.4 191 7 201 305 99 0 99 0 -2.4 0 -2 -2.7 12/31/2004 00:20:00 7 0.7 9.1 4.9 7.4 0.8 9.9 4.9 0.4 0 0.4 0.4 186 5 194 305 98 0 98 0 -2.5 0 -2 -2.7 12/31/2004 00:30:00 7.5 0.7 9.5 5.3 8.3 0.5 9.9 6.8 0.4 0 0.4 0.4 183 5 194 305 100 1 100 0 -2.3 0 -1.8 -2.7 12/31/2004 00:40:00 8.2 0.8 9.5 4.9 8.6 0.5 9.9 7.2 0.4 0 0.4 0.4 188 6 196 305 103 0 103 0 -2.2 0.1 -1.8 -2.2 12/31/2004 00:50:00 8.7 0.4 10.3 7.6 8.7 0.4 9.5 7.2 0.4 0 0.4 0.4 194 3 199 305 102 0 103 0 -2.3 0 -1.8 -2.4 12/31/2004 01:00:00 7.9 0.7 9.5 5.3 8.2 0.6 10.3 6.1 0.4 0 0.4 0.4 192 6 188 305 101 1 101 0 -2.3 0 -1.8 -2.4 12/31/2004 01:10:00 6.9 0.9 9.9 4.6 7.4 0.8 10.3 4.9 0.4 0 0.4 0.4 188 5 189 305 99 1 99 0 -2.4 0 -2 -2.7 12/31/2004 01:20:00 7.7 0.3 8.8 6.8 7.8 0.3 8.8 6.8 0.4 0 0.4 0.4 191 3 192 305 98 0 98 0 -2.5 0 -2.2 -2.7 12/31/2004 01:30:00 7.4 0.4 9.1 6.5 7.4 0.4 9.1 6.1 0.4 0 0.4 0.4 192 4 196 305 97 0 97 0 -2.6 0 -2.2 -2.7 12/31/2004 01:40:00 7.1 0.5 9.5 5.7 7.1 0.4 9.1 6.5 0.4 0 0.4 0.4 193 4 195 305 98 0 97 0 -2.4 0 -2.2 -2.7 12/31/2004 01:50:00 7.1 0.3 8 6.5 7.1 0.3 8.4 6.1 0.4 0 0.4 0.4 195 3 188 305 98 0 98 0 -2.4 0 -2 -2.4 12/31/2004 02:00:00 7.2 0.4 8.8 6.1 7.2 0.4 8.8 6.1 0.4 0 0.4 0.4 195 4 204 305 99 0 98 0 -2.3 0 -2 -2.4 12/31/2004 02:10:00 7.4 0.3 8.8 6.5 7.4 0.3 8.4 6.1 0.4 0 0.4 0.4 194 3 198 305 99 0 100 0 -2.3 0 -2 -2.4 12/31/2004 02:20:00 7.3 0.2 8 6.5 7.4 0.3 8 6.8 0.4 0 0.4 0.4 193 2 194 305 99 0 99 0 -2.3 0 -2 -2.4 12/31/2004 02:30:00 7.1 0.3 8.4 6.1 7.1 0.3 8 6.1 0.4 0 0.4 0.4 195 3 194 305 100 1 99 0 -2.2 0.1 -1.8 -2.4 12/31/2004 02:40:00 6.8 0.3 8 5.7 6.9 0.4 8.4 5.7 0.4 0 0.4 0.4 194 5 200 305 101 0 101 0 -2 0 -1.8 -2 12/31/2004 02:50:00 6.5 0.5 8 4.9 6.5 0.4 8 5.3 0.4 0 0.4 0.4 195 4 196 305 102 0 102 0 -1.9 0 -1.8 -2 12/31/2004 03:00:00 6.7 0.3 7.6 5.7 6.7 0.4 8 5.7 0.4 0 0.4 0.4 193 3 198 305 102 0 101 0 -2 0 -1.3 -2.2 12/31/2004 03:10:00 6.6 0.6 8 4.9 6.6 0.4 7.6 5.7 0.4 0 0.4 0.4 192 4 195 305 102 0 102 0 -1.8 0 -1.8 -2 12/31/2004 03:20:00 6.1 0.5 7.2 4.6 6.2 0.4 7.6 4.9 0.4 0 0.4 0.4 192 5 200 305 102 0 103 0 -1.9 0 -1.8 -2 12/31/2004 03:30:00 6.1 0.5 7.2 4.9 6.2 0.5 7.2 4.9 0.4 0 0.4 0.4 195 5 201 305 103 0 103 0 -1.8 0 -1.8 -2 12/31/2004 03:40:00 6 0.7 7.6 3.8 6.1 0.5 7.2 4.2 0.4 0 0.4 0.4 192 5 200 305 103 0 103 0 -1.8 0 -1.3 -2 12/31/2004 03:50:00 5.9 0.4 6.8 4.9 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 196 4 189 305 104 0 103 0 -1.7 0 -1.5 -1.8 12/31/2004 04:00:00 4.2 0.7 6.1 3 4.1 0.6 5.3 3 0.4 0 0.4 0.4 201 4 203 305 102 0 103 0 -1.9 0 -1.3 -2 12/31/2004 04:10:00 2.7 0.6 4.2 1.9 2.6 0.6 4.2 1.5 0.4 0 0.4 0.4 210 6 214 305 101 1 101 0 -2.1 0.1 -1.5 -2.4 12/31/2004 04:20:00 2 0.2 2.6 1.5 2 0.2 2.6 1.5 0.4 0 0.4 0.4 205 5 205 305 99 1 99 0 -2.2 0 -1.8 -2.4 12/31/2004 04:30:00 2.2 0.4 2.6 1.5 2.1 0.4 3 1.5 0.4 0 0.4 0.4 197 4 204 305 96 1 96 0 -2.2 0 -1.8 -2.4 12/31/2004 04:40:00 1.4 0.4 2.3 0.4 1.2 0.3 1.9 0.4 0.4 0 0.4 0.4 198 8 205 305 94 1 95 0 -2.2 0 -1.8 -2.4 12/31/2004 04:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 197 0 305 305 92 1 93 0 -2.2 0 -1.8 -2.4 12/31/2004 05:00:00 0.4 0.2 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 190 13 156 305 87 1 86 0 -2.5 0.1 -1.8 -2.7 12/31/2004 05:10:00 0.9 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 132 7 131 305 84 1 85 0 -2.9 0 -2.2 -3.1 12/31/2004 05:20:00 0.9 0.4 1.9 0.4 0.9 0.3 1.9 0.4 0.4 0 0.4 0.4 113 3 113 305 82 0 82 0 -3.1 0 -2.7 -3.3 12/31/2004 05:30:00 4.2 1.8 8.4 1.1 4.3 1.9 8.8 1.1 0.4 0 0.4 0.4 94 15 116 305 81 1 83 0 -2.8 0 -2.7 -3.1 12/31/2004 05:40:00 7.6 0.5 8.8 6.1 7.6 0.5 9.1 6.1 0.4 0 0.4 0.4 120 4 122 305 86 1 85 0 -2.9 0 -2.7 -3.1 12/31/2004 05:50:00 8.1 0.6 9.5 6.8 8.1 0.6 9.5 6.8 0.4 0 0.4 0.4 126 4 123 305 87 0 88 0 -3.1 0 -2.9 -3.1 12/31/2004 06:00:00 8.4 0.6 9.9 6.8 8.3 0.6 9.5 6.8 0.4 0 0.4 0.4 121 7 134 305 89 1 88 0 -2.7 0.1 -2.2 -3.1 12/31/2004 06:10:00 7.1 0.6 8.4 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 114 6 112 305 90 0 90 0 -2.6 0 -2.4 -2.7 12/31/2004 06:20:00 7.5 0.7 8.8 5.7 7.2 0.7 8.8 5.3 0.4 0 0.4 0.4 107 5 113 305 90 0 91 0 -2.6 0 -2 -2.7 12/31/2004 06:30:00 7.3 1 9.5 4.2 7 0.9 8.8 4.2 0.4 0 0.4 0.4 106 7 105 305 90 1 89 0 -2.7 0 -2.4 -2.9 12/31/2004 06:40:00 6.6 0.8 9.1 4.9 6.2 0.8 8.8 4.2 0.4 0 0.4 0.4 105 7 101 305 90 1 89 0 -2.7 0 -2.4 -2.9 12/31/2004 06:50:00 7.7 1 10.3 4.6 7.2 0.9 9.1 4.6 0.4 0 0.4 0.4 97 10 98 305 94 2 95 0 -2.2 0.2 -1.8 -2.7 12/31/2004 07:00:00 7.7 1 10.3 4.9 7.3 1 9.5 4.6 0.4 0 0.4 0.4 94 9 92 305 96 0 96 0 -1.8 0 -1.8 -2 12/31/2004 07:10:00 7.6 1.1 10.3 4.9 7.2 1.1 9.9 3.8 0.4 0 0.4 0.4 89 8 89 305 96 1 95 0 -1.8 0 -1.5 -2 12/31/2004 07:20:00 7.7 1 9.9 4.9 7.2 1.1 9.9 4.6 0.4 0 0.4 0.4 90 7 89 305 94 1 93 0 -1.8 0 -1.8 -2 12/31/2004 07:30:00 7.9 0.9 9.5 5.7 7.4 0.9 9.9 5.7 0.4 0 0.4 0.4 84 8 89 305 92 1 91 0 -2 0 -1.3 -2.2 12/31/2004 07:40:00 8.3 1 10.7 6.5 7.8 0.8 9.9 5.3 0.4 0 0.4 0.4 79 8 76 305 91 0 91 0 -1.9 0 -1.8 -2 12/31/2004 07:50:00 10.1 1.2 13.3 6.8 9.6 1.2 13 6.8 0.4 0 0.4 0.4 79 8 84 305 92 1 93 0 -1.7 0 -1.3 -2 12/31/2004 08:00:00 9.4 0.9 11.8 6.8 8.9 0.9 11.8 7.2 0.4 0 0.4 0.4 80 7 68 305 91 1 92 0 -1.9 0.2 -1.3 -2.2 12/31/2004 08:10:00 8.9 1 12.2 6.5 8.4 0.9 11.1 6.1 0.4 0 0.4 0.4 84 9 93 305 89 0 90 0 -2.2 0 -1.8 -2.4 12/31/2004 08:20:00 8.2 0.9 10.7 5.7 7.7 0.9 10.3 5.3 0.4 0 0.4 0.4 84 7 80 305 88 0 89 0 -2.3 0 -1.8 -2.4 12/31/2004 08:30:00 7.6 1.2 11.5 4.2 7.2 1.2 10.7 3.8 0.4 0 0.4 0.4 86 12 73 305 89 0 88 0 -2.4 0 -2 -2.7 12/31/2004 08:40:00 6.3 1.7 12.2 3 5.9 1.7 13.3 2.3 0.4 0 0.4 0.4 82 20 89 305 90 0 90 0 -2.3 0 -1.8 -2.7 12/31/2004 08:50:00 7.3 1.7 12.2 3.4 6.9 1.5 12.2 3 0.4 0 0.4 0.4 78 19 60 305 90 0 90 0 -2.2 0 -1.8 -2.4 12/31/2004 09:00:00 6.6 1.7 11.5 2.3 6.3 1.6 11.5 1.5 0.4 0 0.4 0.4 91 17 103 305 91 0 90 0 -2.4 0 -1.8 -2.7 12/31/2004 09:10:00 5.9 1.6 9.9 2.3 5.4 1.5 9.5 1.5 0.4 0 0.4 0.4 92 19 62 305 90 0 91 0 -2.5 0 -2 -2.7 12/31/2004 09:20:00 6.3 2 13 2.3 6 2.2 12.6 1.9 0.4 0 0.4 0.4 71 20 78 305 90 0 90 0 -2.4 0 -2.2 -2.7 12/31/2004 09:30:00 7.2 1.8 12.2 3.4 6.8 1.9 12.6 1.5 0.4 0 0.4 0.4 77 18 72 305 91 1 91 0 -2.3 0 -2 -2.4 12/31/2004 09:40:00 9.3 1.4 13.7 6.5 8.7 1.4 14.1 5.7 0.4 0 0.4 0.4 82 16 72 305 94 1 93 0 -2.2 0 -1.8 -2.4 12/31/2004 09:50:00 9.1 0.7 11.1 6.8 8.6 0.7 10.7 6.5 0.4 0 0.4 0.4 73 6 74 305 94 0 94 0 -2.2 0 -2 -2.4 12/31/2004 10:00:00 10.4 1.2 15.3 6.8 10 1.3 13.3 6.8 0.4 0 0.4 0.4 77 8 73 305 95 0 95 0 -2.1 0.1 -1.8 -2.2 12/31/2004 10:10:00 10.8 0.9 14.1 8 10.2 1 14.5 7.2 0.4 0 0.4 0.4 77 7 81 305 96 0 96 0 -2 0 -1.8 -2 12/31/2004 10:20:00 11.5 1.3 15.6 8.8 10.9 1.3 14.1 8.4 0.4 0 0.4 0.4 72 6 73 305 96 0 96 0 -2 0 -1.8 -2 12/31/2004 10:30:00 13 1.7 17.9 9.1 12.4 1.7 18.7 8.8 0.4 0 0.4 0.4 75 9 75 305 96 0 95 0 -2 0 -1.8 -2 12/31/2004 10:40:00 11.5 1.3 14.5 8.4 11 1.3 14.5 8 0.4 0 0.4 0.4 77 9 80 305 95 0 95 0 -2 0.1 -1.8 -2.2 12/31/2004 10:50:00 11.8 1.5 17.2 7.6 11.2 1.3 16.1 8 0.4 0 0.4 0.4 76 9 69 305 95 0 95 0 -2 0 -1.8 -2 12/31/2004 11:00:00 12.2 0.9 15.3 9.9 11.7 0.9 14.5 9.5 0.4 0 0.4 0.4 76 5 82 305 95 0 95 0 -2.1 0 -1.8 -2.2 12/31/2004 11:10:00 11.9 0.8 14.5 9.5 11.2 0.9 13.3 8.8 0.4 0 0.4 0.4 71 6 77 305 94 0 94 0 -2.1 0 -1.8 -2.2 12/31/2004 11:20:00 12.2 0.8 14.5 9.5 11.6 0.8 14.1 9.1 0.4 0 0.4 0.4 70 5 71 305 94 0 94 0 -2 0 -1.8 -2.2 12/31/2004 11:30:00 12.8 0.8 14.9 10.7 12.3 0.8 14.1 10.3 0.4 0 0.4 0.4 70 4 72 305 94 0 94 0 -2.1 0 -1.8 -2.2 12/31/2004 11:40:00 13.3 1 16.1 10.3 12.6 1.1 15.6 9.9 0.4 0 0.4 0.4 71 5 71 305 94 0 94 0 -2.1 0 -1.8 -2.2 12/31/2004 11:50:00 13.9 0.9 16.4 11.5 13.4 0.8 15.6 11.1 0.4 0 0.4 0.4 72 5 69 305 94 0 94 0 -2.1 0 -2 -2.2 12/31/2004 12:00:00 14.7 1 17.2 11.5 14 1 16.8 11.1 0.4 0 0.4 0.4 72 5 66 305 94 0 94 0 -2.1 0 -2 -2.2 12/31/2004 12:10:00 14.8 1 18.3 12.2 14.1 1 16.8 11.8 0.4 0 0.4 0.4 73 5 76 305 94 0 95 0 -2.1 0 -1.8 -2.2 12/31/2004 12:20:00 15.3 0.9 17.6 12.6 14.6 0.9 17.2 12.2 0.4 0 0.4 0.4 71 5 71 305 95 0 95 0 -2 0 -1.8 -2 12/31/2004 12:30:00 14.8 0.9 17.9 12.2 14.1 0.9 16.4 11.8 0.4 0 0.4 0.4 70 4 66 305 96 0 96 0 -1.9 0 -1.8 -2 12/31/2004 12:40:00 14 0.8 16.8 11.8 13.4 0.9 16.8 11.5 0.4 0 0.4 0.4 71 5 80 305 97 0 97 0 -1.9 0 -1.8 -2 12/31/2004 12:50:00 13.5 0.9 16.1 11.5 13 0.9 16.1 10.3 0.4 0 0.4 0.4 72 5 72 305 98 0 97 0 -1.8 0 -1.8 -2 12/31/2004 13:00:00 12.9 0.9 16.1 10.3 12.3 0.9 14.5 9.9 0.4 0 0.4 0.4 72 5 77 305 98 0 98 0 -1.7 0 -1.3 -1.8 12/31/2004 13:10:00 13.2 1.5 18.7 9.5 12.6 1.4 17.6 9.5 0.4 0 0.4 0.4 75 6 77 305 100 0 100 0 -1.6 0 -1.1 -1.8 12/31/2004 13:20:00 13.6 1.9 18.3 8.4 13.3 1.8 19.5 8.4 0.4 0 0.4 0.4 76 10 72 305 101 0 101 0 -1.4 0 -1.1 -1.5 12/31/2004 13:30:00 13.9 2.6 21.4 7.2 13.5 2.6 20.6 8 0.4 0 0.4 0.4 79 13 78 305 102 0 102 0 -1.2 0 -1.1 -1.3 12/31/2004 13:40:00 14.3 2.3 21 7.6 13.7 2.3 20.6 8.4 0.4 0 0.4 0.4 78 12 82 305 103 0 103 0 -1.1 0 -1.1 -1.3 12/31/2004 13:50:00 13.6 2.4 20.6 8 13.1 2.3 19.9 7.2 0.4 0 0.4 0.4 80 13 68 305 104 0 103 0 -1.1 0 -1.1 -1.3 12/31/2004 14:00:00 12.6 2.5 20.6 6.5 12 2.5 19.1 6.1 0.4 0 0.4 0.4 82 14 67 305 105 0 105 0 -1.1 0 -0.6 -1.1 12/31/2004 14:10:00 11.2 2.3 17.2 4.9 10.8 2.4 17.6 3.8 0.4 0 0.4 0.4 82 15 47 305 106 0 105 0 -0.9 0 -0.6 -1.1 12/31/2004 14:20:00 10.5 2.2 16.4 5.7 10.1 2.3 15.6 4.6 0.4 0 0.4 0.4 85 18 78 305 106 0 106 0 -0.7 0 -0.6 -0.8 12/31/2004 14:30:00 9.1 2.2 15.6 4.9 8.6 2.3 16.4 3.8 0.4 0 0.4 0.4 97 20 90 305 106 0 106 0 -0.6 0 -0.4 -0.6 12/31/2004 14:40:00 8.9 2.1 14.9 3.8 8.6 1.9 13.7 4.2 0.4 0 0.4 0.4 103 16 115 305 106 0 106 0 -0.3 0 0.1 -0.6 12/31/2004 14:50:00 10 2.5 16.1 4.6 9.6 2.3 15.3 4.2 0.4 0 0.4 0.4 109 14 118 305 106 1 107 0 0.1 0.1 0.3 -0.1 12/31/2004 15:00:00 9.8 1.8 15.3 5.7 9.5 1.7 14.5 4.2 0.4 0 0.4 0.4 109 16 97 305 110 1 111 0 0.2 0 0.6 0.1 12/31/2004 15:10:00 9.7 1.8 14.9 4.6 9.2 1.7 14.1 4.9 0.4 0 0.4 0.4 112 15 90 305 112 1 112 0 0.2 0 0.6 0.1 12/31/2004 15:20:00 10.6 1.9 15.3 4.9 10.1 1.7 14.9 5.3 0.4 0 0.4 0.4 109 13 122 305 109 1 109 0 0.2 0 0.6 0.1 12/31/2004 15:30:00 9.4 2.1 15.6 3.8 9 2 15.6 3 0.4 0 0.4 0.4 106 15 119 305 107 0 107 0 0.1 0.1 0.6 0.1 12/31/2004 15:40:00 5.9 1.7 10.7 1.9 5.5 1.7 10.3 1.1 0.4 0 0.4 0.4 103 22 94 305 107 1 107 0 0 0 0.6 0.1 12/31/2004 15:50:00 4.5 1.6 9.1 1.1 4.4 1.5 9.1 0.7 0.4 0 0.4 0.4 84 35 89 305 109 0 109 0 0 0 0.6 -0.1 12/31/2004 16:00:00 3.2 1.5 7.2 0.4 3.1 1.4 7.2 0.4 0.4 0 0.4 0.4 94 43 109 305 110 1 110 0 -0.1 0 0.3 -0.4 12/31/2004 16:10:00 4.6 1.4 8.8 0.7 4.3 1.3 8 1.5 0.4 0 0.4 0.4 116 29 98 305 111 1 111 0 -0.2 0 0.3 -0.4 12/31/2004 16:20:00 5.3 1.7 9.5 1.9 4.9 1.7 9.1 1.1 0.4 0 0.4 0.4 128 23 136 305 112 0 112 0 -0.1 0 0.3 -0.4 12/31/2004 16:30:00 7.6 1.2 11.1 4.2 7.4 1.3 10.7 3.4 0.4 0 0.4 0.4 132 12 144 305 112 0 112 0 -0.1 0 0.6 -0.1 12/31/2004 16:40:00 8.3 1.5 13 5.3 7.8 1.5 13.3 4.2 0.4 0 0.4 0.4 128 15 146 305 112 0 112 0 -0.1 0 0.6 -0.1 12/31/2004 16:50:00 7.8 1.4 11.8 4.2 7.4 1.3 11.5 4.2 0.4 0 0.4 0.4 127 13 133 305 112 0 112 0 -0.1 0 0.6 -0.4 12/31/2004 17:00:00 7.6 1.5 12.2 4.6 7.3 1.5 11.5 4.2 0.4 0 0.4 0.4 134 11 138 305 112 0 112 0 -0.1 0 0.3 -0.4 12/31/2004 17:10:00 11.8 2.1 16.4 4.9 11.3 2 17.2 4.6 0.4 0 0.4 0.4 137 9 133 305 112 0 112 0 -0.1 0 0.3 -0.4 12/31/2004 17:20:00 11.3 1.5 14.9 7.6 11.1 1.4 15.6 7.2 0.4 0 0.4 0.4 145 10 144 305 113 0 113 0 -0.1 0 0.3 -0.4 12/31/2004 17:30:00 11.6 1.5 15.3 6.8 11.4 1.4 14.9 8.4 0.4 0 0.4 0.4 143 9 138 305 114 1 113 0 -0.1 0 0.6 -0.1 12/31/2004 17:40:00 11.5 1.2 14.9 8.4 11.2 1.2 14.1 8.4 0.4 0 0.4 0.4 139 7 141 305 115 0 115 0 -0.1 0 0.3 -0.1 12/31/2004 17:50:00 11.7 1.3 14.9 8.8 11.3 1.3 14.1 8 0.4 0 0.4 0.4 131 6 130 305 115 0 115 0 -0.1 0 0.3 -0.4 12/31/2004 18:00:00 10.6 1.7 14.1 6.5 10.3 1.6 14.5 6.8 0.4 0 0.4 0.4 130 9 138 305 115 0 115 0 -0.1 0 0.3 -0.4 12/31/2004 18:10:00 9.7 1.7 14.1 6.1 9.4 1.7 14.5 5.3 0.4 0 0.4 0.4 132 11 138 305 115 0 116 0 -0.3 0 0.1 -0.4 12/31/2004 18:20:00 9.3 1.7 13.3 4.6 9.1 1.5 12.6 5.3 0.4 0 0.4 0.4 144 12 135 305 116 0 116 0 -0.3 0 -0.1 -0.4 12/31/2004 18:30:00 10.8 2.1 16.4 4.9 10.6 1.7 15.6 6.1 0.4 0 0.4 0.4 150 9 152 305 117 0 117 0 -0.4 0 0.1 -0.6 12/31/2004 18:40:00 13.8 1.8 18.3 9.5 13.4 1.5 17.6 9.9 0.4 0 0.4 0.4 150 6 151 305 118 0 117 0 -0.5 0 0.1 -0.6 12/31/2004 18:50:00 14.5 1.5 17.9 10.3 13.9 1.4 17.6 9.9 0.4 0 0.4 0.4 150 6 155 305 117 1 118 0 -0.7 0 -0.4 -0.8 12/31/2004 19:00:00 15 1.3 17.9 11.1 14.3 1.2 17.2 11.1 0.4 0 0.4 0.4 148 5 153 305 119 1 118 0 -0.8 0 -0.4 -1.1 12/31/2004 19:10:00 13.9 1.2 16.8 10.3 13.1 1.1 15.6 9.1 0.4 0 0.4 0.4 149 5 151 305 119 1 117 0 -0.9 0 -0.6 -1.1 12/31/2004 19:20:00 11.3 1.5 15.3 6.8 11 1.5 14.9 7.2 0.4 0 0.4 0.4 146 8 153 305 120 1 120 0 -0.8 0 -0.4 -1.1 12/31/2004 19:30:00 10.6 1.5 14.5 7.2 10.3 1.5 14.5 6.8 0.4 0 0.4 0.4 143 9 156 305 121 0 120 0 -0.9 0 -0.4 -1.1 12/31/2004 19:40:00 10.2 1.2 13 6.1 9.9 1.2 13.3 6.8 0.4 0 0.4 0.4 141 9 132 305 121 0 121 0 -0.8 0 -0.4 -1.1 12/31/2004 19:50:00 11.6 1.1 14.5 8.8 11.1 1.1 14.1 8.4 0.4 0 0.4 0.4 137 6 141 305 121 0 121 0 -0.8 0 -0.4 -1.1 12/31/2004 20:00:00 10.9 0.9 12.6 8 10.5 0.8 12.6 8.4 0.4 0 0.4 0.4 136 5 133 305 121 0 121 0 -0.8 0 -0.4 -1.1 12/31/2004 20:10:00 10.6 1 14.1 8 10.3 1 13.3 7.2 0.4 0 0.4 0.4 138 7 120 305 121 0 121 0 -0.7 0 -0.4 -1.1 12/31/2004 20:20:00 10.2 1.3 14.5 6.8 10 1.3 14.5 7.2 0.4 0 0.4 0.4 138 8 139 305 119 0 120 0 -0.6 0 0.1 -0.8 12/31/2004 20:30:00 8.3 1.3 12.2 5.3 8.2 1.3 11.5 4.9 0.4 0 0.4 0.4 141 11 145 305 119 0 119 0 -0.6 0 -0.1 -0.6 12/31/2004 20:40:00 8.9 1.7 13 4.9 8.8 1.5 12.6 4.6 0.4 0 0.4 0.4 147 11 143 305 119 1 118 0 -0.5 0.1 0.1 -0.6 12/31/2004 20:50:00 11.5 1.9 16.8 6.8 11.4 1.7 17.2 7.2 0.4 0 0.4 0.4 148 11 149 305 116 1 117 0 -0.4 0.1 0.1 -0.6 12/31/2004 21:00:00 11.5 1.8 16.4 6.5 11.2 1.7 15.3 6.5 0.4 0 0.4 0.4 148 8 148 305 116 0 117 0 -0.4 0.1 0.1 -0.6 12/31/2004 21:10:00 11.5 2 17.9 6.8 11.2 1.7 17.2 8 0.4 0 0.4 0.4 150 10 158 305 116 0 115 0 -0.3 0 0.1 -0.4 12/31/2004 21:20:00 13.1 1.9 18.7 8.8 12.8 1.7 17.9 8.8 0.4 0 0.4 0.4 150 9 145 305 114 1 114 0 -0.1 0 0.6 -0.1 12/31/2004 21:30:00 13.9 1.6 17.2 8.4 13.7 1.5 17.2 9.9 0.4 0 0.4 0.4 149 8 143 305 112 0 112 0 0 0 0.6 -0.1 12/31/2004 21:40:00 12.8 1.9 17.2 6.8 12.4 1.7 17.6 8.4 0.4 0 0.4 0.4 149 9 142 305 112 0 111 0 0 0 0.1 -0.1 12/31/2004 21:50:00 12.2 1.5 16.4 8 11.8 1.4 15.6 8.8 0.4 0 0.4 0.4 148 8 145 305 111 0 111 0 0 0 0.3 -0.1 12/31/2004 22:00:00 11.6 1.7 15.3 4.9 11.5 1.3 14.5 7.2 0.4 0 0.4 0.4 151 9 143 305 111 0 111 0 0 0 0.6 -0.1 12/31/2004 22:10:00 11.5 1.7 15.6 6.8 11.3 1.5 14.5 7.2 0.4 0 0.4 0.4 148 9 146 305 111 0 112 0 0 0 0.1 -0.1 12/31/2004 22:20:00 11.1 1.5 15.6 6.8 10.7 1.3 14.5 7.6 0.4 0 0.4 0.4 144 10 142 305 111 0 111 0 0 0 0.1 -0.1 12/31/2004 22:30:00 10.5 1.2 13.7 6.8 10.3 1.2 14.1 7.6 0.4 0 0.4 0.4 143 11 143 305 111 0 111 0 -0.1 0 0.3 -0.1 12/31/2004 22:40:00 10.1 1.5 14.1 6.5 10 1.5 14.1 5.7 0.4 0 0.4 0.4 143 11 147 305 111 0 111 0 -0.1 0 0.3 -0.4 12/31/2004 22:50:00 10.4 1.5 14.5 6.1 10.3 1.3 13.7 7.2 0.4 0 0.4 0.4 149 10 143 305 110 0 109 0 -0.1 0 0.1 -0.1 12/31/2004 23:00:00 9.5 1.7 14.5 4.9 9.7 1.4 14.1 5.7 0.4 0 0.4 0.4 154 10 150 305 110 1 110 0 0.2 0 0.8 0.1 12/31/2004 23:10:00 9.7 1.7 14.9 6.1 10 1.3 14.5 6.1 0.4 0 0.4 0.4 155 11 147 305 112 0 111 0 0.4 0 0.8 0.3 12/31/2004 23:20:00 10.4 1.7 14.5 6.5 11.4 1.5 16.1 6.8 0.4 0 0.4 0.4 158 9 162 305 107 3 103 0 0.5 0 0.6 0.3 12/31/2004 23:30:00 10.6 1.7 14.9 6.5 11.9 1.1 14.9 8.8 0.4 0 0.4 0.4 160 6 159 305 98 1 100 0 0.5 0 0.6 0.6 12/31/2004 23:40:00 9.8 1.5 13 5.7 11.4 1 13.7 8.8 0.4 0 0.4 0.4 159 6 143 305 92 2 95 0 0.6 0 1 0.6 12/31/2004 23:50:00 9.9 1.7 15.3 5.7 12 0.9 14.5 9.9 0.4 0 0.4 0.4 161 5 155 305 91 2 93 0 0.7 0.1 1.3 0.6 01/01/2005 00:00:00 10 1.3 13 6.8 12.2 0.8 14.1 9.9 0.4 0 0.4 0.4 161 5 156 305 95 1 93 0 1 0 1.5 0.8 01/01/2005 00:10:00 9.7 1.5 13.7 6.5 12.4 0.9 14.9 9.5 0.4 0 0.4 0.4 163 5 160 305 99 1 98 0 1 0 1.5 0.8 01/01/2005 00:20:00 9.8 1.6 14.1 6.1 11 1.1 13.3 8.8 0.4 0 0.4 0.4 159 6 154 305 102 1 101 0 1.1 0 1.5 1 01/01/2005 00:30:00 10.3 1.4 14.5 6.5 11.3 1.1 14.9 8.8 0.4 0 0.4 0.4 159 7 158 305 103 0 103 0 1.1 0 1.5 1 01/01/2005 00:40:00 10.1 1.3 14.5 6.8 11.1 1.1 13.7 8.4 0.4 0 0.4 0.4 159 6 157 305 105 0 104 0 1.1 0 1.5 1 01/01/2005 00:50:00 10.1 1.3 14.5 7.6 12.4 0.9 14.9 9.9 0.4 0 0.4 0.4 163 6 154 305 106 0 106 0 1.2 0.1 1.5 1 01/01/2005 01:00:00 9.5 1.2 13.3 6.8 11.8 1 14.5 9.5 0.4 0 0.4 0.4 164 5 162 305 107 0 106 0 1.1 0 1.5 0.8 01/01/2005 01:10:00 9.2 1.2 13 6.1 9.7 1 12.6 6.5 0.4 0 0.4 0.4 158 7 150 305 108 1 108 0 0.6 0.1 1.3 0.3 01/01/2005 01:20:00 9.5 1.2 12.6 6.5 9.7 1 13.3 6.8 0.4 0 0.4 0.4 156 8 151 305 109 0 109 0 0.3 0.1 1 0.1 01/01/2005 01:30:00 9.8 1.2 13.3 6.8 10.1 1 13.3 7.6 0.4 0 0.4 0.4 157 6 155 305 111 0 110 0 0.2 0 0.8 0.1 01/01/2005 01:40:00 9.5 1.3 13 6.8 10.8 0.8 12.6 8.4 0.4 0 0.4 0.4 161 6 160 305 112 0 112 0 0.3 0 1 0.1 01/01/2005 01:50:00 10.2 1.4 14.1 7.2 11.8 0.8 14.1 9.5 0.4 0 0.4 0.4 161 4 163 305 113 0 113 0 0.5 0 1 0.3 01/01/2005 02:00:00 11.2 1.4 15.3 7.6 12 1 15.6 9.9 0.4 0 0.4 0.4 159 5 150 305 113 0 113 0 0.5 0 1 0.3 01/01/2005 02:10:00 10.3 1.2 13 7.2 10.4 1 13.3 8 0.4 0 0.4 0.4 155 6 163 305 114 0 114 0 0.3 0 1 0.1 01/01/2005 02:20:00 9.5 1.3 13 6.5 9.3 1.2 12.6 6.8 0.4 0 0.4 0.4 150 7 154 305 114 0 114 0 0 0 0.6 -0.4 01/01/2005 02:30:00 9.7 1.3 13 6.8 9.7 1.1 13 7.2 0.4 0 0.4 0.4 154 6 153 305 114 0 114 0 -0.1 0 0.3 -0.4 01/01/2005 02:40:00 10 1.3 13 6.8 10.2 1 13.3 7.6 0.4 0 0.4 0.4 156 6 155 305 113 0 113 0 0 0 0.6 -0.1 01/01/2005 02:50:00 10 1.3 13.7 6.8 10.7 0.9 13.3 8.4 0.4 0 0.4 0.4 159 5 150 305 113 0 113 0 0.2 0 0.8 0.1 01/01/2005 03:00:00 9.6 1.3 13.3 6.1 9.9 1.2 12.6 6.8 0.4 0 0.4 0.4 157 6 159 305 113 0 113 0 0.4 0 1 0.3 01/01/2005 03:10:00 8.7 1.1 12.2 6.5 8.5 1 11.8 6.1 0.4 0 0.4 0.4 146 8 149 305 112 0 112 0 0.2 0.1 0.8 0.1 01/01/2005 03:20:00 9.5 1.1 13 7.2 9.4 1.1 12.2 6.8 0.4 0 0.4 0.4 146 8 150 305 112 0 112 0 0 0.1 0.6 0.1 01/01/2005 03:30:00 9.5 1.4 13 6.5 9.2 1.2 11.8 6.5 0.4 0 0.4 0.4 146 8 151 305 113 0 112 0 0 0 0.6 -0.1 01/01/2005 03:40:00 11 1.2 14.1 7.6 10.7 1.1 13.7 8 0.4 0 0.4 0.4 147 8 158 305 113 1 114 0 0 0 0.6 -0.1 01/01/2005 03:50:00 11.5 1.4 14.5 7.2 11.4 1.3 14.1 7.6 0.4 0 0.4 0.4 149 7 149 305 114 0 114 0 0 0 0.6 -0.1 01/01/2005 04:00:00 11.1 1.4 14.5 8 10.9 1.2 13.7 8 0.4 0 0.4 0.4 149 7 150 305 113 0 113 0 0 0 0.6 0.1 01/01/2005 04:10:00 10.7 1.1 13.3 8 10.4 1.1 13.7 7.6 0.4 0 0.4 0.4 140 8 143 305 114 0 114 0 0 0 0.6 -0.1 01/01/2005 04:20:00 11.1 0.8 14.1 8.8 10.7 0.8 13.3 8.8 0.4 0 0.4 0.4 134 5 140 305 114 0 114 0 -0.1 0 0.3 -0.4 01/01/2005 04:30:00 11.7 0.9 13.3 9.1 11.5 0.8 13.3 9.1 0.4 0 0.4 0.4 132 4 134 305 114 0 114 0 -0.1 0 0.3 -0.4 01/01/2005 04:40:00 12.5 0.7 14.1 9.9 12.2 0.7 14.1 9.5 0.4 0 0.4 0.4 130 4 130 305 114 0 114 0 -0.2 0 0.3 -0.4 01/01/2005 04:50:00 12.4 1 15.3 9.5 12.1 1 14.5 9.5 0.4 0 0.4 0.4 131 5 123 305 114 0 114 0 -0.3 0 0.3 -0.6 01/01/2005 05:00:00 12.2 0.9 14.5 9.5 11.9 0.9 13.7 9.5 0.4 0 0.4 0.4 132 5 124 305 114 0 114 0 -0.4 0.2 0.1 -0.6 01/01/2005 05:10:00 12.2 0.9 14.5 9.5 11.8 1 14.1 9.1 0.4 0 0.4 0.4 131 4 130 305 113 0 113 0 -0.5 0.1 0.1 -0.6 01/01/2005 05:20:00 12.9 0.8 14.9 9.5 12.6 0.7 14.9 9.9 0.4 0 0.4 0.4 131 4 129 305 113 0 113 0 -0.5 0.1 0.1 -0.6 01/01/2005 05:30:00 12.9 1 14.9 9.9 12.6 1 14.9 9.9 0.4 0 0.4 0.4 133 4 135 305 113 0 113 0 -0.5 0.1 0.1 -0.6 01/01/2005 05:40:00 12.7 0.9 14.5 10.3 12.4 0.9 14.5 10.3 0.4 0 0.4 0.4 132 4 129 305 102 13 81 0 -0.6 0.1 0.1 -0.8 01/01/2005 05:50:00 13.2 0.9 16.1 10.7 13 0.9 16.4 10.3 0.4 0 0.4 0.4 132 4 131 305 80 0 80 0 -0.5 0.1 0.1 -0.6 01/01/2005 06:00:00 13.8 1 17.6 10.7 13.3 1 16.1 10.7 0.4 0 0.4 0.4 131 5 127 305 80 0 80 0 -0.5 0.1 0.1 -0.6 01/01/2005 06:10:00 14.3 1 16.4 11.5 14 1 16.4 11.8 0.4 0 0.4 0.4 131 5 147 305 80 0 80 0 -0.7 0 0.1 -0.8 01/01/2005 06:20:00 13.9 0.9 16.8 10.3 13.6 0.9 16.1 10.7 0.4 0 0.4 0.4 133 4 130 305 78 0 78 0 -0.7 0.1 -0.1 -1.1 01/01/2005 06:30:00 13.4 1 16.4 9.9 13.1 1 15.3 10.7 0.4 0 0.4 0.4 132 5 138 305 77 0 77 0 -0.8 0.1 -0.4 -1.1 01/01/2005 06:40:00 13.2 1.1 15.6 9.5 12.8 1.1 15.6 9.5 0.4 0 0.4 0.4 133 4 136 305 77 0 77 0 -0.8 0 -0.4 -1.1 01/01/2005 06:50:00 14.9 1.9 19.5 10.7 14.5 1.9 18.3 9.9 0.4 0 0.4 0.4 131 5 130 305 78 0 78 0 -0.7 0 -0.1 -0.8 01/01/2005 07:00:00 15.5 1.3 19.1 11.8 15.2 1.3 18.7 12.2 0.4 0 0.4 0.4 135 4 130 305 78 0 78 0 -0.8 0 -0.4 -1.1 01/01/2005 07:10:00 14.8 1.2 17.6 11.5 14.4 1.2 17.2 11.8 0.4 0 0.4 0.4 132 4 135 305 78 0 78 0 -0.8 0 -0.1 -1.1 01/01/2005 07:20:00 14.7 1.3 17.9 11.5 14.4 1.3 17.6 11.5 0.4 0 0.4 0.4 133 4 136 305 78 0 79 0 -0.8 0 -0.4 -0.8 01/01/2005 07:30:00 14.2 1.1 16.8 11.1 13.7 1 16.4 10.7 0.4 0 0.4 0.4 136 5 130 305 79 0 79 0 -0.7 0 -0.1 -0.8 01/01/2005 07:40:00 13.5 1 16.4 11.1 13.2 1 16.1 10.7 0.4 0 0.4 0.4 136 5 138 305 79 0 79 0 -0.7 0 -0.1 -0.8 01/01/2005 07:50:00 13.4 0.9 15.6 10.7 13 0.9 14.9 10.7 0.4 0 0.4 0.4 134 5 139 305 80 1 79 0 -0.7 0 0.1 -0.8 01/01/2005 08:00:00 13.5 0.8 16.1 11.1 13.2 0.7 15.6 11.5 0.4 0 0.4 0.4 130 4 129 305 81 0 81 0 -0.6 0 -0.1 -0.6 01/01/2005 08:10:00 12.8 1.1 15.6 9.9 12.4 1 15.3 9.9 0.4 0 0.4 0.4 132 5 132 305 81 0 81 0 -0.6 0 -0.1 -0.6 01/01/2005 08:20:00 12.2 1 15.3 9.9 11.9 1 14.5 9.5 0.4 0 0.4 0.4 131 5 136 305 83 2 84 0 -0.5 0 -0.1 -0.6 01/01/2005 08:30:00 11.3 1.8 14.5 6.5 11.2 1.7 14.5 6.8 0.4 0 0.4 0.4 139 7 137 305 87 1 86 0 -0.4 0 0.1 -0.6 01/01/2005 08:40:00 9.4 1.9 15.6 4.6 9.1 1.8 15.6 4.2 0.4 0 0.4 0.4 130 11 136 305 89 1 88 0 -0.5 0 0.1 -0.6 01/01/2005 08:50:00 6.3 1.9 13.7 2.3 6 1.7 13 2.3 0.4 0 0.4 0.4 118 22 135 305 90 0 90 0 -0.4 0 0.1 -0.6 01/01/2005 09:00:00 9.9 1.3 13 6.5 9.5 1.3 13 5.7 0.4 0 0.4 0.4 133 8 145 305 90 1 90 0 -0.4 0.2 0.1 -0.6 01/01/2005 09:10:00 7.4 1.7 11.8 3.4 7.2 1.7 11.8 3 0.4 0 0.4 0.4 128 18 124 305 93 1 93 0 -0.3 0.1 0.3 -0.4 01/01/2005 09:20:00 8.4 2.4 13.7 2.6 8.3 2.4 13.3 3.4 0.4 0 0.4 0.4 132 17 140 305 95 1 95 0 -0.3 0.1 0.3 -0.4 01/01/2005 09:30:00 10.7 2.2 17.2 4.9 10.5 2.2 16.1 5.7 0.4 0 0.4 0.4 135 12 135 305 95 1 94 0 -0.3 0.1 0.3 -0.6 01/01/2005 09:40:00 9.2 2.5 15.3 3 9 2.5 15.3 3.4 0.4 0 0.4 0.4 120 19 150 305 93 1 92 0 -0.4 0.2 0.1 -0.6 01/01/2005 09:50:00 8.8 2.2 14.5 3.8 8.5 2 13.7 3.8 0.4 0 0.4 0.4 105 20 119 305 99 2 101 0 -0.1 0 0.3 -0.4 01/01/2005 10:00:00 8.8 2.5 15.6 3.4 8.4 2.3 14.5 3.8 0.4 0 0.4 0.4 115 23 114 305 102 1 102 0 -0.1 0 0.3 -0.4 01/01/2005 10:10:00 7.7 2.3 16.4 1.9 7.4 2.5 15.3 1.5 0.4 0 0.4 0.4 108 24 124 305 108 2 108 0 0 0.1 0.6 0.1 01/01/2005 10:20:00 9 2.8 18.7 3 8.5 2.7 16.4 2.3 0.4 0 0.4 0.4 105 28 118 305 113 2 114 0 0.3 0.1 1 0.1 01/01/2005 10:30:00 8.8 2.5 14.9 3 8.2 2.4 14.9 0.4 0.4 0 0.4 0.4 104 28 114 305 117 1 118 0 0.7 0.1 1.3 0.6 01/01/2005 10:40:00 8.3 2.1 15.3 3.4 7.9 2.1 14.1 3.8 0.4 0 0.4 0.4 98 27 130 305 119 0 119 0 1 0.1 1.5 0.8 01/01/2005 10:50:00 9.6 2.2 18.3 3.8 9.1 2.1 17.2 4.6 0.4 0 0.4 0.4 76 20 74 305 118 1 118 0 0.4 0.5 1.3 -0.4 01/01/2005 11:00:00 10 2.6 17.2 4.2 9.4 2.7 19.1 3 0.4 0 0.4 0.4 75 23 60 305 121 2 122 0 -0.5 0.1 0.1 -0.6 01/01/2005 11:10:00 11.6 2.5 19.5 5.3 11.6 2.7 19.9 6.1 0.4 0 0.4 0.4 70 20 56 305 106 5 106 0 -0.6 0 0.1 -0.8 01/01/2005 11:20:00 12.2 2.8 19.5 4.6 12.2 3.1 19.9 4.6 0.4 0 0.4 0.4 69 16 66 305 100 1 101 0 -0.8 0 -0.1 -1.1 01/01/2005 11:30:00 14.5 2.1 21.4 10.3 14.6 2.2 20.2 9.1 0.4 0 0.4 0.4 68 9 65 305 104 1 102 0 -0.6 0 0.1 -0.8 01/01/2005 11:40:00 13.3 3.3 23.7 6.5 13.1 3.6 23.7 5.3 0.4 0 0.4 0.4 70 17 87 305 105 1 106 0 -0.5 0 0.1 -0.6 01/01/2005 11:50:00 13.7 3.2 24.4 6.5 13.6 3.5 25.2 4.6 0.4 0 0.4 0.4 69 17 80 305 104 1 104 0 -0.6 0 0.1 -0.6 01/01/2005 12:00:00 14.2 3.1 22.1 7.6 14.2 3.2 22.1 5.7 0.4 0 0.4 0.4 67 15 64 305 104 0 104 0 -0.6 0 0.1 -0.6 01/01/2005 12:10:00 13.8 2.9 22.9 7.2 13.8 3.1 22.6 6.1 0.4 0 0.4 0.4 67 14 62 305 106 1 107 0 -0.5 0 0.1 -0.6 01/01/2005 12:20:00 13.3 3.2 22.1 5.7 13.4 3.2 22.1 5.3 0.4 0 0.4 0.4 65 15 66 305 108 0 108 0 -0.5 0.1 0.1 -0.6 01/01/2005 12:30:00 11.3 2.7 18.7 4.6 11.3 2.8 18.3 4.6 0.4 0 0.4 0.4 59 14 64 305 110 1 109 0 -0.3 0.1 0.3 -0.6 01/01/2005 12:40:00 11.3 3.2 21 3 10.7 3.2 19.1 3 0.4 0 0.4 0.4 70 20 60 305 116 2 116 0 0 0.1 0.6 -0.1 01/01/2005 12:50:00 11.6 3.5 22.6 3.8 11.3 3.3 21.8 4.9 0.4 0 0.4 0.4 67 20 50 305 122 3 119 0 0.3 0 0.8 0.1 01/01/2005 13:00:00 10.3 3.3 19.1 2.3 9.8 3.3 17.9 2.6 0.4 0 0.4 0.4 84 26 86 305 117 3 119 0 0.2 0 0.6 0.1 01/01/2005 13:10:00 8.6 2.9 19.1 3.4 8.3 3.1 20.2 1.9 0.4 0 0.4 0.4 95 29 102 305 112 3 110 0 0.1 0.1 0.6 0.1 01/01/2005 13:20:00 8.6 2.5 17.6 2.6 8.4 2.4 15.6 2.6 0.4 0 0.4 0.4 76 28 56 305 111 2 112 0 0 0.1 0.6 0.1 01/01/2005 13:30:00 8 2.4 15.3 2.3 7.7 2.5 13.3 2.3 0.4 0 0.4 0.4 82 28 43 305 112 0 112 0 0 0.1 0.6 0.1 01/01/2005 13:40:00 8.9 2.6 14.9 1.9 8.6 2.6 14.5 3.4 0.4 0 0.4 0.4 77 26 67 305 112 0 112 0 0.1 0.1 0.6 0.1 01/01/2005 13:50:00 8 2.5 16.4 1.9 7.6 2.6 16.4 2.6 0.4 0 0.4 0.4 74 26 87 305 113 1 112 0 0 0.1 0.6 0.1 01/01/2005 14:00:00 7.5 2.6 14.9 2.3 7.1 2.6 14.9 1.9 0.4 0 0.4 0.4 85 30 96 305 112 1 113 0 0.1 0.1 0.6 0.1 01/01/2005 14:10:00 7.8 2.6 16.1 1.5 7.1 2.5 13 1.1 0.4 0 0.4 0.4 82 27 77 305 112 0 112 0 0.1 0.1 0.6 0.1 01/01/2005 14:20:00 10.1 2.9 20.2 3.8 9.6 3.3 21.4 2.3 0.4 0 0.4 0.4 79 28 51 305 114 1 115 0 0.2 0.1 0.6 0.1 01/01/2005 14:30:00 10.4 3.5 18.7 4.2 10 3.5 19.5 3.4 0.4 0 0.4 0.4 73 22 62 305 117 1 116 0 0.2 0.1 0.6 0.1 01/01/2005 14:40:00 10.4 2.5 17.6 5.7 10.1 2.7 17.2 4.2 0.4 0 0.4 0.4 72 22 89 305 118 0 117 0 0.1 0.1 0.6 0.1 01/01/2005 14:50:00 9.9 3.2 18.3 2.6 9.6 3.3 19.5 2.6 0.4 0 0.4 0.4 77 22 58 305 119 0 119 0 0.1 0.1 0.6 0.1 01/01/2005 15:00:00 9.4 2.9 17.6 3.4 8.9 3.1 17.9 3.4 0.4 0 0.4 0.4 71 22 79 305 120 0 120 0 0 0.1 0.6 -0.1 01/01/2005 15:10:00 8.1 2.6 16.4 3.4 7.7 2.6 17.9 3 0.4 0 0.4 0.4 83 26 84 305 121 0 121 0 0 0.1 0.6 0.1 01/01/2005 15:20:00 7.5 2.6 15.6 1.5 7.2 2.5 15.3 2.3 0.4 0 0.4 0.4 93 27 136 305 121 1 122 0 0 0.1 0.6 -0.1 01/01/2005 15:30:00 7.2 2.3 14.9 3 6.7 2.1 13.7 2.3 0.4 0 0.4 0.4 96 30 138 305 121 1 121 0 0 0.1 0.6 -0.1 01/01/2005 15:40:00 6.7 2.4 14.9 1.9 6.3 2 13.7 1.5 0.4 0 0.4 0.4 97 32 74 305 122 1 121 0 0 0.1 0.6 -0.1 01/01/2005 15:50:00 7.3 2.7 14.5 1.5 6.9 2.4 14.5 1.9 0.4 0 0.4 0.4 112 32 133 305 123 1 123 0 0 0 0.6 -0.1 01/01/2005 16:00:00 7.2 2.6 14.9 1.1 6.8 2.4 12.2 1.5 0.4 0 0.4 0.4 104 32 140 305 122 1 122 0 -0.1 0 0.3 -0.4 01/01/2005 16:10:00 6.1 1.7 10.7 1.9 5.8 1.7 11.1 2.3 0.4 0 0.4 0.4 91 28 103 305 122 0 122 0 -0.2 0 0.3 -0.4 01/01/2005 16:20:00 7.1 2 14.1 3 6.8 2.1 14.5 1.9 0.4 0 0.4 0.4 105 29 105 305 122 1 123 0 -0.2 0 0.3 -0.4 01/01/2005 16:30:00 8.3 2.3 16.8 3.8 7.8 2.4 15.6 2.6 0.4 0 0.4 0.4 111 26 126 305 123 1 124 0 -0.1 0 0.3 -0.4 01/01/2005 16:40:00 8.3 2.2 14.5 3.8 7.8 2.2 14.1 2.6 0.4 0 0.4 0.4 105 22 103 305 123 1 123 0 -0.1 0 0.3 -0.4 01/01/2005 16:50:00 7.5 2.1 14.1 2.6 7.1 1.9 12.6 2.3 0.4 0 0.4 0.4 107 21 118 305 122 0 122 0 -0.1 0 0.3 -0.4 01/01/2005 17:00:00 7.3 1.8 13.3 3.8 6.8 1.8 13 3.4 0.4 0 0.4 0.4 119 20 107 305 123 1 122 0 -0.2 0 0.1 -0.4 01/01/2005 17:10:00 9.4 2.3 15.6 4.6 9 2.3 17.2 4.6 0.4 0 0.4 0.4 121 17 116 305 123 0 122 0 -0.2 0 0.1 -0.4 01/01/2005 17:20:00 11 2 16.8 6.5 10.6 1.9 16.1 6.1 0.4 0 0.4 0.4 129 15 136 305 123 0 123 0 -0.1 0 0.1 -0.4 01/01/2005 17:30:00 11.3 2.1 17.9 6.5 10.8 2 17.2 6.5 0.4 0 0.4 0.4 131 11 147 305 122 0 122 0 -0.1 0 0.3 -0.1 01/01/2005 17:40:00 11.3 1.5 15.6 8 10.8 1.4 14.9 7.6 0.4 0 0.4 0.4 134 10 150 305 123 0 123 0 -0.1 0 0.1 -0.4 01/01/2005 17:50:00 11.5 1.2 17.2 8.8 10.9 1.2 15.6 8.4 0.4 0 0.4 0.4 134 7 145 305 123 0 123 0 -0.1 0 0.1 -0.4 01/01/2005 18:00:00 11 1 13.3 8.4 10.3 1 13 6.8 0.4 0 0.4 0.4 134 5 143 305 123 0 123 0 -0.1 0 0.3 -0.4 01/01/2005 18:10:00 9.3 1.4 13.3 4.9 9 1.2 11.8 5.3 0.4 0 0.4 0.4 138 10 141 305 123 0 123 0 -0.1 0.1 0.3 -0.4 01/01/2005 18:20:00 10.2 1.1 14.1 7.2 9.7 1 12.6 6.8 0.4 0 0.4 0.4 138 8 135 305 123 0 123 0 -0.1 0.1 0.3 -0.4 01/01/2005 18:30:00 9.1 1.1 11.8 6.5 8.8 1 11.5 6.5 0.4 0 0.4 0.4 145 9 155 305 123 0 123 0 -0.1 0 0.3 -0.4 01/01/2005 18:40:00 9.6 1.2 13 6.1 9.3 1.1 12.6 6.5 0.4 0 0.4 0.4 151 7 148 305 124 0 124 0 -0.1 0 0.3 -0.4 01/01/2005 18:50:00 9.1 1.2 11.8 4.9 9 1 11.8 6.8 0.4 0 0.4 0.4 155 6 155 305 124 0 124 0 -0.1 0.1 0.3 -0.4 01/01/2005 19:00:00 8.5 1 11.5 6.1 10.3 0.8 12.6 8 0.4 0 0.4 0.4 163 5 161 305 124 0 125 0 -0.1 0 0.3 -0.4 01/01/2005 19:10:00 8.8 0.9 12.2 6.5 10.9 1 13.3 8.4 0.4 0 0.4 0.4 171 6 174 305 125 0 125 0 -0.1 0 0.3 -0.4 01/01/2005 19:20:00 10.3 0.7 12.6 8.4 10.6 0.8 13.3 8.4 0.4 0 0.4 0.4 182 3 184 305 125 0 125 0 -0.1 0 0.3 -0.4 01/01/2005 19:30:00 11.4 0.9 13.3 9.5 11.1 1 13.7 8.8 0.4 0 0.4 0.4 189 3 190 305 125 0 125 0 -0.3 0.1 0.3 -0.4 01/01/2005 19:40:00 11.4 0.7 13.3 9.5 10.9 0.8 13 8 0.4 0 0.4 0.4 191 3 196 305 125 0 125 0 -0.4 0.1 0.1 -0.6 01/01/2005 19:50:00 12.3 0.6 13.7 10.3 11.5 0.8 13.7 8.4 0.4 0 0.4 0.4 194 3 193 305 127 2 131 0 -0.5 0.1 0.1 -0.6 01/01/2005 20:00:00 12.2 0.7 14.5 10.3 11.5 0.8 13.7 9.1 0.4 0 0.4 0.4 195 3 196 305 130 1 130 0 -0.7 0 -0.1 -0.8 01/01/2005 20:10:00 12.1 0.6 13.7 10.3 11.6 0.8 13.7 9.5 0.4 0 0.4 0.4 196 3 194 305 126 1 126 0 -0.8 0 -0.4 -1.1 01/01/2005 20:20:00 11.6 0.6 13 9.9 11 0.8 13 8.8 0.4 0.1 0.7 0.4 197 3 196 305 124 0 124 0 -0.8 0 -0.6 -1.1 01/01/2005 20:30:00 12.6 0.9 14.9 9.9 12 1 14.1 9.1 0.4 0.2 0.7 0.4 200 3 195 305 122 0 122 0 -0.9 0 -0.4 -1.1 01/01/2005 20:40:00 13.4 1.1 16.1 11.1 12.8 1.1 15.6 9.9 0.5 0.2 0.7 0.4 202 3 200 305 121 0 120 0 -1 0.1 -0.6 -1.1 01/01/2005 20:50:00 14.1 0.9 16.4 12.2 13.4 1 15.6 10.3 0.5 0.2 0.7 0.4 200 3 197 305 120 0 120 0 -1 0.1 -0.6 -1.1 01/01/2005 21:00:00 13.9 0.8 16.1 11.5 13.2 0.9 15.3 10.3 0.4 0.1 0.7 0.4 198 3 197 305 121 1 120 0 -1 0.1 -0.4 -1.1 01/01/2005 21:10:00 14 0.9 16.1 11.5 13.4 1 15.6 9.9 0.4 0 0.7 0.4 199 3 199 305 120 0 121 0 -1 0.1 -0.4 -1.1 01/01/2005 21:20:00 14.7 0.9 16.8 11.8 14 1 16.1 10.7 0.4 0.1 0.7 0.4 198 3 198 305 120 0 120 0 -0.9 0 -0.4 -1.1 01/01/2005 21:30:00 14.7 0.9 17.2 12.6 14.1 1 16.4 10.7 0.4 0.1 0.7 0.4 200 3 198 305 121 0 121 0 -1 0.1 -0.4 -1.1 01/01/2005 21:40:00 13.7 0.8 16.1 11.1 13.1 1 15.3 9.5 0.5 0.2 0.7 0.4 198 3 199 305 120 0 120 0 -1 0.1 -0.4 -1.1 01/01/2005 21:50:00 13.6 0.8 15.6 11.1 13 0.9 15.3 9.9 0.5 0.2 0.7 0.4 198 2 196 305 119 0 119 0 -1.1 0 -0.4 -1.1 01/01/2005 22:00:00 13.5 0.6 15.3 11.5 13 0.8 14.9 10.7 0.4 0.1 0.7 0.4 198 3 197 305 118 0 118 0 -1 0.1 -0.6 -1.1 01/01/2005 22:10:00 12.7 0.8 14.9 10.3 12.1 0.8 14.1 9.9 0.4 0 0.7 0.4 198 3 198 305 121 1 119 0 -1 0 -0.6 -1.1 01/01/2005 22:20:00 13 0.7 14.5 11.1 12.5 0.9 14.5 10.3 0.4 0.1 0.7 0.4 198 3 200 305 125 1 125 0 -0.8 0 -0.4 -1.1 01/01/2005 22:30:00 13 0.8 15.6 11.1 12.4 0.9 14.9 9.9 0.5 0.2 0.7 0.4 199 3 199 305 130 1 129 0 -0.5 0 0.1 -0.6 01/01/2005 22:40:00 12.9 0.8 15.3 11.1 12.4 0.9 14.9 9.5 0.5 0.2 0.7 0.4 199 3 198 305 130 1 130 0 -0.5 0 0.1 -0.6 01/01/2005 22:50:00 13.8 0.8 16.1 11.5 13.2 1 15.6 9.9 0.4 0.1 0.7 0.4 196 3 194 305 130 0 131 0 -0.5 0.1 0.1 -0.6 01/01/2005 23:00:00 15.1 1.2 18.3 11.8 14.4 1.4 17.9 9.9 0.4 0.1 0.7 0.4 195 3 198 305 132 0 133 0 -0.4 0.1 0.3 -0.4 01/01/2005 23:10:00 15.8 1 17.9 12.6 15 1.1 17.9 12.2 0.4 0.1 0.7 0.4 196 3 196 305 133 0 133 0 -0.4 0.2 0.1 -0.6 01/01/2005 23:20:00 17 1.1 20.2 14.5 16.2 1.3 20.2 12.6 0.4 0.1 0.7 0.4 197 1 197 305 132 0 132 0 -0.2 0.1 0.3 -0.4 01/01/2005 23:30:00 15.5 1 17.6 12.2 15.3 1.1 17.6 11.1 0.5 0.2 0.7 0.4 197 0 197 305 133 0 133 0 -0.3 0.1 0.3 -0.4 01/01/2005 23:40:00 14.9 1.3 19.1 11.8 15.2 1.2 18.7 11.5 0.4 0.1 0.7 0.4 197 0 197 305 133 0 133 0 -0.3 0.1 0.3 -0.4 01/01/2005 23:50:00 14.3 1 16.8 11.8 14.8 1.1 17.6 11.5 0.4 0 0.4 0.4 197 0 197 305 132 0 132 0 -0.4 0.1 0.1 -0.6 01/02/2005 00:00:00 13.4 1 16.1 10.3 14 1 16.8 10.7 0.4 0 0.4 0.4 197 0 197 305 133 1 133 0 -0.5 0 0.1 -0.6 01/02/2005 00:10:00 12.4 0.9 15.3 10.3 13.1 1 15.6 10.7 0.4 0.1 0.7 0.4 197 0 197 305 136 1 136 0 -0.6 0 -0.6 -0.6 01/02/2005 00:20:00 12.1 0.7 14.1 10.7 12.7 0.9 14.9 10.3 0.4 0.1 0.7 0.4 197 0 197 305 134 1 136 0 -0.7 0 -0.6 -0.8 01/02/2005 00:30:00 11.3 0.7 13 9.5 11.8 0.8 13.7 9.9 0.4 0 0.4 0.4 197 0 197 305 130 1 130 0 -0.8 0 -0.6 -1.1 01/02/2005 00:40:00 11.5 0.7 13.3 9.1 11.8 0.8 14.5 8.8 0.4 0 0.4 0.4 197 0 197 305 127 1 127 0 -0.8 0 -0.4 -1.1 01/02/2005 00:50:00 11.5 0.7 12.6 9.9 11.6 0.8 13.3 9.5 0.4 0 0.4 0.4 197 0 197 305 124 1 125 0 -1 0 -0.6 -1.1 01/02/2005 01:00:00 11 0.7 13 9.1 11.1 0.9 13.7 8.8 0.4 0 0.4 0.4 197 0 197 305 120 1 121 0 -1.1 0 -0.8 -1.1 01/02/2005 01:10:00 11.1 0.6 12.6 9.5 11.3 0.7 13 8.4 0.4 0 0.4 0.4 197 0 197 305 118 1 118 0 -1.2 0 -1.1 -1.3 01/02/2005 01:20:00 11.1 0.6 12.6 9.5 11.3 0.7 13 9.5 0.4 0 0.4 0.4 197 0 197 305 115 1 115 0 -1.4 0 -1.1 -1.5 01/02/2005 01:30:00 10.8 0.6 12.6 9.1 11 0.7 13.3 9.1 0.4 0 0.4 0.4 197 0 197 305 112 1 112 0 -1.5 0 -1.3 -1.5 01/02/2005 01:40:00 9.5 1.3 12.2 5.7 11 0.9 13 8.8 0.4 0 0.4 0.4 197 0 197 305 114 3 114 0 -1.3 0.2 -0.8 -1.5 01/02/2005 01:50:00 8.1 1.3 12.2 5.3 11.6 1.1 15.3 8.4 0.4 0 0.4 0.4 197 0 197 305 122 2 124 0 -0.8 0 -0.4 -1.1 01/02/2005 02:00:00 8.5 1.2 12.6 6.1 13.5 1.3 16.8 10.3 0.4 0 0.4 0.4 197 0 197 305 125 1 125 0 -0.7 0 -0.6 -0.8 01/02/2005 02:10:00 8.8 1 13.3 6.8 14.3 1.1 18.3 10.3 0.4 0 0.4 0.4 197 0 197 305 126 1 125 0 -0.6 0 -0.6 -0.6 01/02/2005 02:20:00 8.6 0.9 13 6.5 14 1 16.8 10.7 0.4 0 0.4 0.4 197 0 197 305 126 0 126 0 -0.6 0 -0.6 -0.6 01/02/2005 02:30:00 8.9 1 13.3 6.5 14.1 1 16.4 9.9 0.4 0 0.4 0.4 197 0 197 305 127 1 126 0 -0.6 0 -0.4 -0.6 01/02/2005 02:40:00 9 1 13 6.8 14 1.2 17.6 10.7 0.4 0 0.4 0.4 197 0 197 305 126 0 126 0 -0.5 0 -0.4 -0.6 01/02/2005 02:50:00 8.7 1 13.3 6.5 13.1 1.1 16.1 9.9 0.4 0 0.4 0.4 197 0 197 305 126 1 126 0 -0.5 0 -0.4 -0.6 01/02/2005 03:00:00 9 1 12.2 6.8 13.9 1.1 16.4 10.7 0.4 0 0.4 0.4 197 0 197 305 128 0 128 0 -0.5 0 0.1 -0.6 01/02/2005 03:10:00 8.8 0.9 12.2 6.5 13.9 1 16.8 11.5 0.4 0 0.4 0.4 197 0 197 305 128 0 128 0 -0.6 0 -0.1 -0.8 01/02/2005 03:20:00 8.9 1 12.2 6.5 13.7 1 16.1 10.7 0.4 0 0.4 0.4 197 0 197 305 128 0 128 0 -0.8 0 -0.4 -0.8 01/02/2005 03:30:00 7.9 0.9 11.1 6.1 12.2 1 14.5 9.1 0.4 0 0.4 0.4 197 0 197 305 128 0 128 0 -0.8 0 -0.6 -1.1 01/02/2005 03:40:00 7.4 0.9 11.1 5.7 11.7 0.9 13.7 9.1 0.4 0 0.4 0.4 197 0 197 305 128 0 128 0 -0.7 0 -0.4 -0.8 01/02/2005 03:50:00 7.7 0.9 11.1 5.7 12.1 1.1 14.5 9.1 0.4 0 0.4 0.4 197 0 197 305 128 0 128 0 -0.6 0 -0.1 -0.6 01/02/2005 04:00:00 7.8 0.8 11.1 5.7 12 0.9 14.1 8.8 0.4 0 0.4 0.4 197 0 197 305 129 0 129 0 -0.5 0 -0.4 -0.6 01/02/2005 04:10:00 7.8 1.1 11.5 4.9 11.3 1 13.3 8 0.4 0 0.4 0.4 197 0 197 305 129 0 130 0 -0.5 0 -0.4 -0.6 01/02/2005 04:20:00 8.9 1.4 13 6.1 11.9 1.2 15.3 7.6 0.4 0 0.4 0.4 197 0 197 305 129 0 129 0 -0.5 0 -0.4 -0.6 01/02/2005 04:30:00 9.2 1.4 13.3 6.5 12.2 1.1 16.8 8.4 0.4 0 0.4 0.4 197 0 197 305 129 0 129 0 -0.5 0 -0.4 -0.6 01/02/2005 04:40:00 9 1.6 13.3 6.1 11.6 1.2 15.3 8.4 0.4 0 0.4 0.4 197 0 197 305 129 0 129 0 -0.5 0 -0.4 -0.6 01/02/2005 04:50:00 8.9 1.5 13 5.3 11 1.4 15.6 8 0.4 0 0.4 0.4 197 0 197 305 129 0 128 0 -0.5 0 -0.4 -0.6 01/02/2005 05:00:00 8.8 1.7 12.2 4.9 9.8 1.5 13.7 5.7 0.4 0 0.4 0.4 197 0 197 305 128 0 128 0 -0.6 0 -0.1 -0.8 01/02/2005 05:10:00 9.9 1.6 14.1 5.3 10.3 1.3 14.1 6.8 0.4 0 0.4 0.4 197 0 197 305 128 0 128 0 -0.7 0 -0.4 -0.8 01/02/2005 05:20:00 9.9 1.3 13.3 6.1 10.2 1.2 13.3 7.2 0.4 0 0.4 0.4 197 0 197 305 127 0 127 0 -0.7 0 -0.4 -0.8 01/02/2005 05:30:00 9.8 1.3 13 6.8 10.1 1.5 14.5 7.2 0.4 0 0.4 0.4 197 1 197 305 127 0 127 0 -0.8 0 -0.4 -1.1 01/02/2005 05:40:00 10.2 1.5 13.3 6.1 10.5 1.5 13.7 6.8 0.4 0 0.4 0.4 197 0 197 305 127 0 127 0 -0.9 0 -0.4 -1.1 01/02/2005 05:50:00 11.5 1.2 14.9 8 11.8 1.3 14.9 8 0.4 0 0.4 0.4 197 0 197 305 127 0 128 0 -1 0 -0.6 -1.1 01/02/2005 06:00:00 11.4 1.3 14.5 7.6 11.6 1.3 14.9 8.4 0.4 0 0.4 0.4 197 0 197 305 127 1 126 0 -1 0.1 -0.4 -1.1 01/02/2005 06:10:00 11.7 1.2 14.5 8 12 1.3 15.6 9.1 0.4 0 0.4 0.4 197 0 197 305 128 1 128 0 -1 0 -0.6 -1.1 01/02/2005 06:20:00 11 1.5 15.6 7.6 11.3 1.5 16.1 7.6 0.4 0 0.4 0.4 197 0 197 305 128 0 128 0 -1 0 -0.4 -1.1 01/02/2005 06:30:00 11 1.4 14.9 6.8 11.4 1.5 15.3 8.4 0.4 0 0.4 0.4 197 0 197 305 129 0 129 0 -0.8 0 -0.4 -1.1 01/02/2005 06:40:00 11.5 1.7 15.6 7.6 11.8 1.5 16.4 8.4 0.4 0 0.4 0.4 197 0 197 305 128 0 128 0 -0.7 0 -0.6 -0.8 01/02/2005 06:50:00 11.7 1.6 16.1 7.2 12.1 1.5 16.1 7.6 0.4 0 0.4 0.4 197 0 199 305 127 0 127 0 -0.6 0 0.1 -0.6 01/02/2005 07:00:00 11.7 2 16.1 5.7 12.1 2 17.2 6.5 0.4 0 0.4 0.4 197 0 197 305 128 0 127 0 -0.6 0 0.1 -0.6 01/02/2005 07:10:00 11.5 1.7 16.1 6.8 11.9 1.6 16.4 8 0.4 0 0.4 0.4 197 0 197 305 127 0 127 0 -0.5 0 0.1 -0.6 01/02/2005 07:20:00 11.6 1.8 16.1 6.5 12.1 1.7 17.2 8 0.4 0 0.4 0.4 197 0 197 305 127 0 127 0 -0.5 0 0.1 -0.6 01/02/2005 07:30:00 11.9 1.8 16.4 6.8 12.5 1.5 16.8 8.8 0.4 0 0.4 0.4 197 0 197 305 127 0 126 0 -0.5 0.1 0.1 -0.6 01/02/2005 07:40:00 11.5 2.2 16.8 6.1 12.1 1.9 16.4 6.8 0.4 0 0.4 0.4 197 0 197 305 126 0 126 0 -0.5 0 0.1 -0.6 01/02/2005 07:50:00 11.4 2 16.1 6.1 11.9 1.7 16.1 7.2 0.4 0 0.4 0.4 197 0 197 305 126 0 126 0 -0.5 0 0.1 -0.6 01/02/2005 08:00:00 10.9 1.8 16.8 5.7 11.4 1.6 16.1 6.8 0.4 0 0.4 0.4 197 0 197 305 126 0 126 0 -0.4 0 -0.4 -0.6 01/02/2005 08:10:00 11.3 1.7 15.6 6.5 11.8 1.4 15.6 8.4 0.4 0 0.4 0.4 197 0 197 305 126 0 126 0 -0.4 0 -0.4 -0.4 01/02/2005 08:20:00 10.9 1.7 15.6 6.8 11.2 1.6 15.3 7.2 0.4 0 0.4 0.4 197 0 197 305 126 0 126 0 -0.4 0 -0.4 -0.4 01/02/2005 08:30:00 11 1.6 14.9 5.7 11.3 1.5 15.3 6.8 0.4 0 0.4 0.4 197 0 197 305 125 0 125 0 -0.4 0 -0.4 -0.4 01/02/2005 08:40:00 11.3 2.1 16.4 5.7 11.7 2 16.8 6.1 0.4 0 0.4 0.4 197 0 197 305 124 0 124 0 -0.3 0 -0.4 -0.4 01/02/2005 08:50:00 12.2 1.5 15.6 7.6 12.3 1.6 16.4 8.4 0.4 0 0.4 0.4 197 0 197 305 123 0 123 0 -0.4 0 -0.4 -0.4 01/02/2005 09:00:00 12.1 1.5 17.2 8 12.2 1.6 17.6 7.6 0.4 0 0.4 0.4 197 0 197 305 123 0 123 0 -0.4 0 0.1 -0.6 01/02/2005 09:10:00 10.4 1.6 14.5 6.1 10.8 1.7 15.6 7.6 0.4 0 0.4 0.4 197 0 197 305 123 0 122 0 -0.4 0 0.1 -0.4 01/02/2005 09:20:00 10.6 1.5 14.1 6.8 10.9 1.6 15.3 6.5 0.4 0 0.4 0.4 197 0 197 305 122 0 122 0 -0.3 0 -0.1 -0.4 01/02/2005 09:30:00 11.7 1.5 16.1 8.4 12 1.5 16.4 7.6 0.4 0 0.4 0.4 197 0 197 305 121 0 121 0 -0.4 0 0.1 -0.6 01/02/2005 09:40:00 10.1 1.7 14.9 6.5 10.5 1.7 15.6 6.8 0.4 0 0.4 0.4 197 0 196 305 121 0 121 0 -0.4 0 0.1 -0.6 01/02/2005 09:50:00 10.6 1.6 15.6 6.8 10.8 1.5 15.6 6.1 0.4 0 0.4 0.4 197 0 197 305 120 0 120 0 -0.4 0 0.1 -0.6 01/02/2005 10:00:00 12.4 1.6 16.1 7.6 12.6 1.6 16.1 8 0.4 0 0.4 0.4 197 0 196 305 120 0 120 0 -0.5 0 -0.4 -0.6 01/02/2005 10:10:00 12.5 1 15.3 9.5 12.6 1.1 15.3 9.1 0.4 0 0.4 0.4 197 0 197 305 120 0 120 0 -0.5 0 -0.4 -0.6 01/02/2005 10:20:00 13.3 1.3 16.1 8.4 13.3 1.3 17.2 9.1 0.4 0 0.4 0.4 197 0 197 305 120 0 120 0 -0.5 0 -0.4 -0.6 01/02/2005 10:30:00 13.1 1.5 16.4 7.6 13 1.4 16.1 9.9 0.4 0 0.4 0.4 197 0 197 305 120 0 120 0 -0.5 0 -0.4 -0.6 01/02/2005 10:40:00 12.6 1.5 16.4 8.4 12.9 1.6 16.4 8.8 0.4 0 0.4 0.4 197 0 197 305 119 0 119 0 -0.5 0 -0.4 -0.6 01/02/2005 10:50:00 13.6 1.5 17.6 9.5 13.7 1.6 17.6 9.5 0.4 0 0.4 0.4 197 0 197 305 119 0 118 0 -0.4 0 -0.4 -0.6 01/02/2005 11:00:00 12 1.7 16.1 7.2 12.2 1.7 16.4 6.8 0.4 0 0.4 0.4 197 0 197 305 118 0 118 0 -0.4 0.1 0.1 -0.6 01/02/2005 11:10:00 11.3 1.7 16.1 7.2 11.5 1.7 16.1 8 0.4 0 0.4 0.4 197 0 197 305 117 0 117 0 -0.4 0 0.1 -0.4 01/02/2005 11:20:00 11.7 1.6 16.4 6.8 11.9 1.7 16.4 6.8 0.4 0 0.4 0.4 197 0 199 305 118 0 117 0 -0.3 0 0.1 -0.4 01/02/2005 11:30:00 12 1.7 17.6 8 12.1 1.7 16.8 8.4 0.4 0 0.4 0.4 197 0 197 305 119 1 120 0 -0.2 0 0.3 -0.4 01/02/2005 11:40:00 13 1.2 15.6 9.9 12.9 1.1 15.6 9.9 0.4 0 0.4 0.4 197 0 197 305 120 0 120 0 -0.3 0 0.1 -0.4 01/02/2005 11:50:00 12.4 1.2 16.1 8.8 12.2 1.1 14.9 9.1 0.4 0 0.4 0.4 197 0 197 305 120 0 120 0 -0.3 0 0.3 -0.4 01/02/2005 12:00:00 11.8 1.5 15.6 7.6 11.7 1.5 16.4 7.6 0.4 0 0.4 0.4 197 0 197 305 120 0 120 0 -0.3 0 0.3 -0.4 01/02/2005 12:10:00 13.2 1.5 16.8 9.1 13 1.5 17.2 8.8 0.4 0 0.4 0.4 197 0 196 305 121 0 121 0 -0.3 0 0.3 -0.4 01/02/2005 12:20:00 13.4 1.2 16.8 10.3 13.3 1.2 16.4 10.3 0.4 0.1 0.7 0.4 197 0 196 305 123 1 122 0 -0.3 0 0.3 -0.4 01/02/2005 12:30:00 13.8 1.5 17.2 9.9 13.7 1.5 17.6 9.9 0.4 0.1 0.7 0.4 197 0 196 305 125 1 126 0 -0.1 0 0.3 -0.4 01/02/2005 12:40:00 13.1 1.7 17.6 8 13.1 1.7 17.2 8.4 0.4 0 0.4 0.4 197 0 196 305 126 0 126 0 -0.1 0 0.3 -0.1 01/02/2005 12:50:00 12.6 1.5 16.8 8.4 12.7 1.4 16.4 9.1 0.4 0 0.4 0.4 197 0 196 305 126 1 127 0 -0.1 0 0.3 -0.1 01/02/2005 13:00:00 11.8 1.9 16.1 6.8 11.7 1.8 16.1 6.1 0.4 0 0.4 0.4 197 0 196 305 125 0 125 0 0 0 0.3 -0.1 01/02/2005 13:10:00 11.7 1.7 16.1 7.6 11.6 1.5 16.4 8 0.4 0 0.4 0.4 197 0 196 305 117 2 116 0 0 0 0.6 0.1 01/02/2005 13:20:00 13.4 1.3 17.2 9.9 13.1 1.4 16.8 9.1 0.4 0 0.4 0.4 196 0 196 305 116 0 116 0 0 0 0.6 0.1 01/02/2005 13:30:00 13.3 1.3 16.4 10.3 13.1 1.2 16.4 9.9 0.4 0 0.4 0.4 196 0 196 305 117 0 117 0 0 0 0.1 0.1 01/02/2005 13:40:00 13.4 1.3 16.4 9.9 13.1 1.3 16.4 9.9 0.4 0 0.4 0.4 196 0 196 305 118 0 117 0 0 0 0.3 0.1 01/02/2005 13:50:00 13.4 1.6 17.2 8.4 13.2 1.5 18.3 8.4 0.4 0 0.4 0.4 196 0 196 305 119 1 119 0 0 0 0.1 -0.1 01/02/2005 14:00:00 12.4 1.9 17.2 6.8 12.3 1.9 17.6 7.6 0.4 0 0.4 0.4 196 0 196 305 119 0 118 0 0 0 0.3 -0.1 01/02/2005 14:10:00 11.9 1.7 16.4 8 11.9 1.6 15.6 7.6 0.4 0 0.4 0.4 196 0 196 305 120 1 120 0 0 0 0.3 -0.1 01/02/2005 14:20:00 12.1 1.7 17.9 8 12.1 1.6 16.4 7.6 0.4 0 0.4 0.4 196 0 196 305 124 1 123 0 0 0 0.3 -0.1 01/02/2005 14:30:00 12.6 1.7 17.2 7.6 12.8 1.5 17.2 8.4 1.5 3.5 16.8 0.4 197 0 196 305 128 1 127 0 0.1 0.1 0.6 0.1 01/02/2005 14:40:00 12.1 2 16.4 6.8 12.3 1.7 16.1 8 12.3 1.8 16.1 7.2 196 0 196 305 131 1 130 0 0.2 0.1 0.6 0.1 01/02/2005 14:50:00 12.4 2.5 17.9 7.2 12.9 2.2 17.9 7.6 12.9 2.2 17.9 7.6 196 0 195 305 133 0 133 0 0.3 0 0.8 0.1 01/02/2005 15:00:00 13.2 2.6 19.9 8 13.8 2.2 19.9 8.4 13.8 2.2 19.9 8.4 195 0 194 305 136 2 135 0 0.3 0 0.8 0.3 01/02/2005 15:10:00 12.7 2.5 18.7 7.2 13.5 2.1 18.3 8.8 9.5 6.1 17.9 0.4 193 1 193 305 136 4 128 0 0.4 0 1 0.1 01/02/2005 15:20:00 12.7 2.2 17.9 8.8 13.4 1.9 18.7 8.8 0.4 0 0.4 0.4 191 1 191 305 131 2 132 0 0.4 0 1 0.3 01/02/2005 15:30:00 13.2 2.5 21 8 13.7 2.1 19.5 8.4 0.4 0 0.4 0.4 183 12 184 305 134 2 136 0 0.5 0 1 0.6 01/02/2005 15:40:00 12.4 2 17.9 7.2 12.6 1.9 17.9 7.2 0.4 0 0.4 0.4 152 12 139 305 133 0 133 0 0.5 0 1 0.3 01/02/2005 15:50:00 12.9 1.9 18.3 7.2 13.3 1.8 17.9 8.4 0.4 0 0.4 0.4 152 10 146 305 132 0 132 0 0.5 0 1 0.3 01/02/2005 16:00:00 13.1 2.2 19.1 8.4 13.7 2 19.9 9.9 0.4 0 0.4 0.4 154 10 150 305 133 0 133 0 0.5 0 1 0.3 01/02/2005 16:10:00 13.5 2.1 19.1 9.1 14.7 1.9 19.9 10.7 0.4 0 0.4 0.4 156 9 159 305 132 0 132 0 0.5 0 1 0.3 01/02/2005 16:20:00 15.1 2.2 20.6 9.9 17 1.9 21.8 11.8 0.4 0 0.4 0.4 160 8 152 305 132 0 132 0 0.6 0.1 1 0.6 01/02/2005 16:30:00 15 1.9 19.9 10.7 17.3 1.6 21.8 13 0.4 0 0.4 0.4 164 6 153 305 132 0 132 0 0.6 0.1 1.3 0.6 01/02/2005 16:40:00 16.7 2.3 22.9 11.8 19.2 1.7 23.3 14.9 0.4 0 0.4 0.4 164 5 158 305 132 0 132 0 0.6 0.1 1.3 0.6 01/02/2005 16:50:00 16.8 2.3 22.9 11.5 19 1.7 23.7 14.5 0.4 0 0.4 0.4 163 6 164 305 133 0 132 0 0.7 0.1 1.3 0.6 01/02/2005 17:00:00 15.4 1.9 20.2 10.7 17.8 1.7 21.8 12.2 0.4 0 0.4 0.4 163 6 165 305 133 0 133 0 0.6 0 1 0.6 01/02/2005 17:10:00 14.1 1.9 18.7 9.5 15.8 1.7 20.2 11.1 0.4 0 0.4 0.4 162 7 163 305 133 0 133 0 0.6 0 1.3 0.6 01/02/2005 17:20:00 13.9 1.9 19.1 9.9 16.1 1.7 21.4 11.1 0.4 0 0.4 0.4 163 6 159 305 133 0 133 0 0.6 0 1 0.6 01/02/2005 17:30:00 13.5 1.9 19.5 9.1 15.9 1.6 19.9 11.5 0.4 0 0.4 0.4 164 6 159 305 133 0 133 0 0.5 0 1.3 0.3 01/02/2005 17:40:00 14 1.6 17.9 10.7 16.5 1.5 20.2 13 0.4 0 0.4 0.4 164 6 153 305 133 0 133 0 0.5 0 1 0.6 01/02/2005 17:50:00 14.3 1.7 19.5 10.7 17.6 1.8 22.6 12.2 0.4 0 0.4 0.4 166 5 162 305 134 0 134 0 0.5 0 1 0.3 01/02/2005 18:00:00 16 1.7 20.6 11.5 20.3 1.7 24.8 14.9 0.4 0 0.4 0.4 167 5 158 305 134 0 135 0 0.5 0 1 0.6 01/02/2005 18:10:00 15 1.5 20.6 11.5 19 2 24 14.5 0.4 0 0.4 0.4 169 6 175 305 135 0 135 0 0.6 0 1 0.6 01/02/2005 18:20:00 14.7 1.5 20.6 10.3 17.9 1.8 23.3 13.3 0.4 0 0.4 0.4 172 6 182 305 136 0 136 0 0.7 0 1 0.6 01/02/2005 18:30:00 17.2 2.2 22.9 11.1 18.9 1.7 24 13.7 0.4 0 0.4 0.4 177 5 181 305 137 0 137 0 0.7 0.1 1.3 0.6 01/02/2005 18:40:00 18.7 1.7 24.4 13.7 19 1.5 24.4 14.9 0.4 0 0.4 0.4 183 5 181 305 137 0 137 0 0.4 0 1 0.3 01/02/2005 18:50:00 21.4 1.7 26 17.2 20.9 1.7 25.6 16.8 0.4 0 0.4 0.4 187 4 186 305 140 1 142 0 0.5 0 1 0.3 01/02/2005 19:00:00 22.6 1.5 26.3 18.3 22.1 1.8 26.3 16.1 0.4 0 0.4 0.4 190 3 186 305 141 0 141 0 0.5 0 1 0.6 01/02/2005 19:10:00 22.4 1.5 26.3 16.8 21.5 1.7 26 16.4 0.4 0 0.4 0.4 190 4 191 305 140 0 140 0 0.5 0 1 0.6 01/02/2005 19:20:00 22.4 1.4 26.3 16.8 21.5 1.7 25.2 15.6 0.4 0 0.4 0.4 192 3 190 305 140 0 140 0 0.5 0 1.3 0.6 01/02/2005 19:30:00 21.8 1.3 25.6 17.2 20.7 1.7 24.8 16.1 0.4 0 0.4 0.4 193 3 196 305 140 0 139 0 0.5 0 1 0.6 01/02/2005 19:40:00 22.2 1.7 26.8 17.9 21 1.9 26.8 15.3 0.4 0 0.4 0.4 192 3 200 305 139 0 140 0 0.4 0 1 0.3 01/02/2005 19:50:00 21.6 1.5 25.6 16.8 20.5 1.7 24.8 16.4 0.4 0 0.4 0.4 193 4 188 305 139 0 139 0 0.5 0 1 0.3 01/02/2005 20:00:00 21.2 1.3 25.2 17.6 20.3 1.6 24.8 14.9 0.4 0 0.4 0.4 195 4 194 305 139 0 139 0 0.4 0 1 0.3 01/02/2005 20:10:00 21.2 1.2 25.2 17.9 20.2 1.5 23.7 16.1 0.4 0 0.4 0.4 197 3 194 305 139 0 139 0 0.4 0 1 0.3 01/02/2005 20:20:00 22.1 1.4 26 18.3 21.1 1.6 25.6 15.6 0.4 0 0.4 0.4 198 4 198 305 139 0 139 0 0.4 0 1 0.3 01/02/2005 20:30:00 21.6 1.3 25.2 18.3 20.8 1.5 24 16.4 0.4 0 0.4 0.4 200 4 203 305 139 0 139 0 0.4 0 0.8 0.3 01/02/2005 20:40:00 22 1.4 25.6 18.3 21.1 1.5 24 16.8 0.4 0 0.4 0.4 201 3 203 305 138 0 139 0 0.4 0 0.6 0.3 01/02/2005 20:50:00 22.2 1.5 26 17.9 21.5 1.5 25.6 16.8 0.4 0 0.4 0.4 203 4 202 305 138 0 138 0 0.5 0 1 0.3 01/02/2005 21:00:00 21.2 1.5 25.2 17.2 20.6 1.5 25.2 16.8 0.4 0 0.4 0.4 203 4 201 305 138 0 138 0 0.4 0 0.8 0.3 01/02/2005 21:10:00 20.7 1.5 25.2 17.6 19.9 1.7 25.2 16.1 0.4 0 0.4 0.4 202 4 197 305 138 0 138 0 0.3 0 0.8 0.3 01/02/2005 21:20:00 22 1.7 27.1 17.6 21.3 1.7 25.6 16.8 0.4 0 0.4 0.4 202 3 202 305 138 0 138 0 0.4 0 0.8 0.3 01/02/2005 21:30:00 22.3 1.7 26.3 18.3 21.5 1.8 25.6 17.2 0.4 0 0.4 0.4 202 3 204 305 138 0 138 0 0.4 0 0.8 0.3 01/02/2005 21:40:00 22.6 1.5 26 19.1 21.7 1.6 25.2 17.6 0.4 0 0.4 0.4 202 4 198 305 138 0 138 0 0.3 0 1 0.1 01/02/2005 21:50:00 21.2 1.4 24.4 16.8 20.4 1.6 24 15.3 0.4 0 0.4 0.4 201 4 196 305 138 0 138 0 0.1 0.1 0.6 0.1 01/02/2005 22:00:00 21.5 1.4 24.4 18.3 20.7 1.5 24.8 16.8 0.4 0 0.4 0.4 201 3 199 305 138 0 137 0 0.1 0.1 0.6 0.1 01/02/2005 22:10:00 21.7 1.3 25.6 16.8 20.9 1.6 25.2 16.1 0.4 0 0.4 0.4 202 4 204 305 138 0 138 0 0 0 0.6 -0.1 01/02/2005 22:20:00 21 1.4 24.8 17.9 20.2 1.5 24 16.8 0.4 0 0.4 0.4 201 4 200 305 138 0 137 0 0 0 0.6 -0.1 01/02/2005 22:30:00 20.3 1.3 23.3 16.4 19.3 1.5 23.3 15.6 0.4 0 0.4 0.4 200 4 201 305 138 0 138 0 -0.1 0 0.3 -0.4 01/02/2005 22:40:00 20.1 1.3 23.3 15.6 19.2 1.5 22.9 15.3 0.4 0 0.4 0.4 200 4 201 305 138 0 137 0 -0.2 0 0.3 -0.4 01/02/2005 22:50:00 19.9 1.5 23.7 16.1 19.1 1.7 23.7 13.7 0.4 0 0.4 0.4 199 4 196 305 138 0 138 0 -0.3 0 0.3 -0.6 01/02/2005 23:00:00 20.5 1.4 24.4 17.2 19.7 1.5 24 15.3 0.4 0 0.4 0.4 200 4 199 305 138 0 138 0 -0.3 0 0.1 -0.4 01/02/2005 23:10:00 20 1.3 23.3 16.1 19.1 1.5 22.6 14.5 0.4 0 0.4 0.4 200 4 203 305 140 0 140 0 -0.3 0 0.1 -0.4 01/02/2005 23:20:00 19.8 1.2 22.9 16.8 18.8 1.3 21.8 15.6 0.4 0 0.4 0.4 200 4 200 305 141 0 141 0 -0.3 0 0.3 -0.4 01/02/2005 23:30:00 21.1 1.6 25.6 17.2 19.9 1.7 24.4 16.1 0.4 0 0.4 0.4 201 4 203 305 142 1 142 0 -0.3 0 0.3 -0.4 01/02/2005 23:40:00 20.6 1.7 24.8 16.8 19.7 1.7 24.4 14.5 0.4 0 0.4 0.4 200 3 200 305 142 0 142 0 -0.4 0 0.1 -0.6 01/02/2005 23:50:00 21.1 1.7 26 17.2 20.2 1.8 25.6 14.9 0.4 0 0.4 0.4 200 3 201 305 142 0 143 0 -0.4 0.1 0.1 -0.6 01/03/2005 00:00:00 21.1 1.7 25.2 16.4 20.1 1.8 24.8 15.6 0.4 0 0.4 0.4 200 4 210 305 142 0 142 0 -0.4 0.1 0.1 -0.6 01/03/2005 00:10:00 21.3 1.3 25.2 17.6 20.3 1.5 24.8 16.1 0.4 0 0.4 0.4 200 4 201 305 142 0 142 0 -0.4 0 0.1 -0.4 01/03/2005 00:20:00 20.3 1.3 24 17.2 19.3 1.4 23.7 15.6 0.4 0 0.4 0.4 201 3 206 305 141 0 141 0 -0.4 0 0.1 -0.4 01/03/2005 00:30:00 20.1 1.5 23.7 15.3 19.2 1.6 22.9 14.9 0.4 0 0.4 0.4 201 4 200 305 140 0 141 0 -0.4 0.1 0.1 -0.4 01/03/2005 00:40:00 20.8 1.7 25.2 16.8 20.1 1.8 24.8 15.6 0.4 0 0.4 0.4 202 4 201 305 140 0 139 0 -0.5 0 0.1 -0.6 01/03/2005 00:50:00 21.2 1.4 24.8 17.9 20.4 1.5 24.8 17.6 0.4 0 0.4 0.4 203 3 206 305 139 0 139 0 -0.7 0 -0.4 -0.8 01/03/2005 01:00:00 20.6 1.5 24 16.8 19.7 1.5 24 16.1 0.4 0 0.4 0.4 205 4 205 305 138 1 139 0 -1 0.1 -0.6 -1.1 01/03/2005 01:10:00 20.1 1.6 23.7 15.6 19.3 1.7 23.7 14.9 0.4 0 0.4 0.4 204 4 205 305 137 0 137 0 -0.9 0 -0.4 -1.1 01/03/2005 01:20:00 19.9 1.5 24.8 16.8 19.2 1.5 23.3 15.6 0.4 0 0.4 0.4 205 4 199 305 136 0 136 0 -0.8 0 -0.4 -1.1 01/03/2005 01:30:00 20.8 1.3 24.4 16.1 19.9 1.6 23.7 14.5 0.4 0 0.4 0.4 206 4 211 305 135 0 135 0 -0.7 0 -0.1 -0.8 01/03/2005 01:40:00 19.7 1.6 24.4 16.1 19 1.6 23.7 15.6 0.4 0 0.4 0.4 205 4 202 305 135 0 136 0 -0.7 0 -0.4 -0.8 01/03/2005 01:50:00 18.5 1.4 22.1 15.3 17.9 1.5 21.8 13.3 0.4 0 0.4 0.4 202 4 204 305 135 0 135 0 -0.8 0.1 -0.4 -1.1 01/03/2005 02:00:00 18.4 1.5 22.1 14.5 17.8 1.5 21.4 13.3 0.4 0 0.4 0.4 203 4 204 305 134 0 133 0 -0.7 0.1 -0.1 -1.1 01/03/2005 02:10:00 18.1 1.5 21.8 14.9 17.5 1.6 21 13.3 0.4 0 0.4 0.4 202 4 210 305 135 0 136 0 -0.5 0 0.1 -0.6 01/03/2005 02:20:00 17.7 1.2 21 14.5 17.1 1.3 20.6 13.3 0.4 0 0.4 0.4 201 4 202 305 135 0 136 0 -0.6 0 0.1 -0.6 01/03/2005 02:30:00 18 1.3 23.3 13.7 17.5 1.3 21.8 13.7 0.4 0 0.4 0.4 201 4 203 305 132 1 131 0 -0.6 0 -0.1 -0.6 01/03/2005 02:40:00 17.6 1.3 20.6 14.1 16.9 1.3 19.9 13.3 0.4 0 0.4 0.4 202 5 203 305 131 0 131 0 -0.6 0 0.1 -0.8 01/03/2005 02:50:00 16.7 1.3 21 13 16.1 1.3 20.2 12.2 0.4 0 0.4 0.4 201 4 202 305 129 0 130 0 -0.7 0 -0.4 -0.8 01/03/2005 03:00:00 16.9 1.4 21.4 13.7 16.2 1.5 20.2 12.2 0.4 0 0.4 0.4 201 4 208 305 128 0 128 0 -0.7 0 -0.4 -0.8 01/03/2005 03:10:00 16.5 1.3 20.2 12.2 15.8 1.3 18.7 12.6 0.4 0 0.4 0.4 199 5 188 305 126 1 126 0 -0.7 0 -0.4 -1.1 01/03/2005 03:20:00 16.1 1 18.7 13.3 15.4 1.2 18.7 12.2 0.4 0 0.4 0.4 198 4 196 305 123 1 123 0 -0.8 0.1 -0.4 -1.1 01/03/2005 03:30:00 17 1.3 20.6 13.3 16.4 1.4 19.5 12.6 0.4 0 0.4 0.4 199 4 198 305 122 2 122 0 -1 0.1 -0.4 -1.1 01/03/2005 03:40:00 17 1.1 20.2 14.1 16.4 1.2 19.5 13.3 0.4 0 0.4 0.4 201 4 201 305 119 1 118 0 -1 0.2 -0.4 -1.1 01/03/2005 03:50:00 16.7 1.2 20.6 13 16.1 1.2 19.5 13.3 0.4 0 0.4 0.4 199 4 204 305 118 0 117 0 -1.1 0.1 -0.4 -1.3 01/03/2005 04:00:00 16.6 1.3 19.9 13 15.9 1.4 19.5 12.2 0.4 0 0.4 0.4 199 4 203 305 117 0 117 0 -1.1 0 -0.6 -1.1 01/03/2005 04:10:00 15.9 1.1 19.1 11.8 15.2 1.2 18.3 12.2 0.4 0 0.4 0.4 199 5 200 305 116 1 116 0 -1.1 0 -0.6 -1.3 01/03/2005 04:20:00 14.9 1.1 17.6 11.1 14.3 1.2 16.8 10.3 0.4 0 0.4 0.4 198 4 198 305 117 1 117 0 -1.1 0 -0.6 -1.3 01/03/2005 04:30:00 15.2 1 18.7 12.6 14.7 1.1 18.3 11.8 0.4 0 0.4 0.4 196 4 200 305 113 1 113 0 -1.2 0 -0.6 -1.3 01/03/2005 04:40:00 15 1 18.3 11.8 14.3 1.2 17.9 11.1 0.4 0 0.4 0.4 196 4 194 305 111 0 111 0 -1.2 0 -0.6 -1.3 01/03/2005 04:50:00 15 1 17.9 13 14.3 1.1 16.8 11.1 0.4 0 0.4 0.4 195 4 200 305 111 0 112 0 -1.2 0 -0.8 -1.3 01/03/2005 05:00:00 15.3 1.2 18.3 11.8 14.6 1.3 17.9 10.7 0.4 0 0.4 0.4 196 4 195 305 111 0 111 0 -1.3 0 -1.1 -1.3 01/03/2005 05:10:00 15.1 1 17.6 13 14.6 1.1 17.6 11.1 0.4 0 0.4 0.4 198 3 199 305 111 0 111 0 -1.4 0 -1.3 -1.5 01/03/2005 05:20:00 15.4 1 18.3 13 14.9 1.1 17.9 11.5 0.4 0 0.4 0.4 198 4 205 305 109 1 109 0 -1.5 0 -1.3 -1.8 01/03/2005 05:30:00 15.1 1.2 18.3 12.2 14.4 1.3 17.6 11.1 0.4 0 0.4 0.4 197 4 203 305 106 1 107 0 -1.6 0 -1.3 -1.8 01/03/2005 05:40:00 15.5 1.1 18.7 13 14.9 1.3 18.3 11.1 0.4 0 0.4 0.4 198 4 199 305 104 0 104 0 -1.7 0 -1.3 -2 01/03/2005 05:50:00 15.3 1 17.6 12.2 14.9 1.1 17.2 11.1 0.4 0 0.4 0.4 199 4 195 305 99 2 104 0 -1.8 0 -1.3 -2 01/03/2005 06:00:00 14.8 0.9 17.2 13 14.3 1 17.2 11.8 0.4 0 0.4 0.4 199 4 196 305 96 0 95 0 -2 0 -1.8 -2.2 01/03/2005 06:10:00 15 0.8 17.9 13 14.4 1 16.8 11.8 0.4 0 0.4 0.4 197 4 196 305 95 0 95 0 -2 0 -1.8 -2 01/03/2005 06:20:00 14.9 1 17.6 12.2 14.1 1.2 17.2 11.1 0.4 0 0.4 0.4 195 3 201 305 94 1 93 0 -2.2 0 -2 -2.4 01/03/2005 06:30:00 14.3 1 16.8 12.2 13.7 1.1 16.4 10.3 0.4 0 0.4 0.4 195 4 207 305 93 0 93 0 -2.3 0 -2.2 -2.4 01/03/2005 06:40:00 13.7 0.9 17.2 11.5 13.1 0.9 16.4 10.3 0.4 0 0.4 0.4 197 4 198 305 92 0 92 0 -2.4 0 -2 -2.7 01/03/2005 06:50:00 13.6 0.9 16.4 10.7 13 1 16.1 9.9 0.4 0 0.4 0.4 196 4 198 305 93 0 93 0 -2.3 0 -2.2 -2.4 01/03/2005 07:00:00 13.5 1 16.4 10.3 12.9 1.1 16.4 9.5 0.4 0 0.4 0.4 197 4 201 305 94 0 93 0 -2.3 0 -1.8 -2.4 01/03/2005 07:10:00 13.5 1 15.6 10.7 13 1 15.6 9.5 0.4 0 0.4 0.4 198 4 195 305 95 1 94 0 -2.2 0 -2 -2.4 01/03/2005 07:20:00 13.5 0.8 15.6 11.1 13 1 14.9 10.3 0.4 0 0.4 0.4 197 4 191 305 94 0 95 0 -2.2 0 -2 -2.4 01/03/2005 07:30:00 12.5 0.7 14.5 9.9 11.9 0.9 13.7 9.5 0.4 0 0.4 0.4 196 4 201 305 93 1 93 0 -2.4 0.1 -2.2 -2.7 01/03/2005 07:40:00 11.9 0.8 14.1 9.9 11.2 1 13.7 8.8 0.4 0 0.4 0.4 194 4 197 305 90 1 89 0 -2.9 0 -2.7 -3.1 01/03/2005 07:50:00 12.7 1 14.9 8.8 12 1 14.5 8.4 0.4 0 0.4 0.4 197 4 203 305 88 1 87 0 -2.7 0 -2.4 -2.9 01/03/2005 08:00:00 12.9 0.8 15.6 10.3 12.2 1 14.9 9.5 0.4 0 0.4 0.4 197 4 196 305 87 0 87 0 -2.6 0.1 -2 -2.7 01/03/2005 08:10:00 12.2 0.8 14.1 9.9 11.6 1 13.7 8.8 0.4 0 0.4 0.4 197 4 198 305 86 0 87 0 -2.7 0.2 -2.2 -3.1 01/03/2005 08:20:00 12.7 0.8 15.3 10.7 12 0.9 14.9 9.5 0.4 0 0.4 0.4 196 4 196 305 87 1 87 0 -2.8 0 -2.4 -2.9 01/03/2005 08:30:00 12.7 0.8 14.5 10.3 11.9 0.9 14.1 9.5 0.4 0 0.4 0.4 196 3 196 305 87 0 88 0 -2.9 0 -2.2 -3.1 01/03/2005 08:40:00 13.3 0.7 15.3 11.1 12.7 0.8 14.9 9.1 0.4 0 0.4 0.4 197 3 196 305 89 0 88 0 -2.8 0 -2.2 -2.9 01/03/2005 08:50:00 12.9 0.6 15.3 11.5 12.4 0.8 14.9 10.3 0.4 0 0.4 0.4 197 3 195 305 90 1 90 0 -2.7 0 -2.2 -2.9 01/03/2005 09:00:00 12.8 0.7 14.9 10.7 12.2 0.9 14.5 9.1 0.4 0 0.4 0.4 197 3 195 305 92 0 91 0 -2.8 0 -2.2 -3.1 01/03/2005 09:10:00 12.9 0.8 15.6 11.1 12.2 1 14.5 8.8 0.4 0 0.4 0.4 199 4 206 305 92 0 91 0 -2.8 0 -2.7 -2.9 01/03/2005 09:20:00 12.9 0.7 14.5 11.1 12.4 0.7 14.5 8.8 0.4 0 0.4 0.4 200 3 203 305 92 1 92 0 -2.7 0 -2.7 -2.7 01/03/2005 09:30:00 12.4 0.7 14.5 9.9 11.9 0.9 14.1 9.1 0.4 0 0.4 0.4 199 4 208 305 92 0 92 0 -2.8 0 -2.7 -2.9 01/03/2005 09:40:00 12.6 0.8 14.9 10.7 11.9 0.9 14.1 9.5 0.4 0 0.4 0.4 198 4 196 305 89 2 89 0 -2.8 0 -2.7 -3.1 01/03/2005 09:50:00 12.6 0.7 15.3 10.7 11.8 0.7 14.9 9.5 0.4 0 0.4 0.4 196 3 203 305 82 1 82 0 -3.1 0.1 -2.7 -3.3 01/03/2005 10:00:00 12.2 0.6 13.7 10.3 11.5 0.8 13.3 9.1 0.4 0 0.4 0.4 196 4 197 305 79 1 77 0 -3.1 0.1 -2.7 -3.3 01/03/2005 10:10:00 11.7 0.8 13.7 9.5 11 0.8 13 8 0.4 0 0.4 0.4 196 3 197 305 77 0 77 0 -3.1 0.1 -2.4 -3.3 01/03/2005 10:20:00 11 0.7 13.3 8.4 10.4 0.7 12.6 8 0.4 0 0.4 0.4 192 4 195 305 74 2 76 0 -3.5 0.3 -2.7 -4 01/03/2005 10:30:00 11.3 0.7 13.3 9.9 11 0.6 13.3 9.5 0.4 0 0.4 0.4 189 3 196 305 71 0 71 0 -4 0 -3.6 -4.2 01/03/2005 10:40:00 11 0.7 13.3 9.5 10.4 0.7 13.3 8.4 0.4 0 0.4 0.4 192 3 195 305 71 1 71 0 -4 0.1 -3.3 -4.5 01/03/2005 10:50:00 11.5 0.6 13.7 9.9 10.9 0.7 12.6 7.6 0.4 0 0.4 0.4 192 4 203 305 69 0 69 0 -4.1 0 -3.3 -4.2 01/03/2005 11:00:00 11 0.7 13 9.1 10.1 0.8 13 8 0.4 0 0.4 0.4 195 4 194 305 69 0 69 0 -3.9 0 -3.8 -4.2 01/03/2005 11:10:00 10.7 0.6 12.6 9.1 10.2 0.7 12.2 8.4 0.4 0 0.4 0.4 193 3 198 305 67 0 66 0 -4.4 0 -4 -4.7 01/03/2005 11:20:00 11.1 0.5 12.6 9.9 10.6 0.5 11.8 9.1 0.4 0 0.4 0.4 192 3 194 305 67 0 66 0 -4.4 0 -4.2 -4.5 01/03/2005 11:30:00 11.7 0.6 13.7 10.3 11.2 0.8 13.3 9.1 0.4 0 0.4 0.4 190 2 189 305 67 0 67 0 -4.4 0 -4 -4.5 01/03/2005 11:40:00 12.6 0.5 14.1 11.1 11.9 0.6 13.3 9.1 0.4 0 0.4 0.4 192 3 187 305 68 0 68 0 -4.1 0 -3.8 -4.2 01/03/2005 11:50:00 11.8 1 14.5 9.9 11.1 0.9 13.7 9.5 0.4 0 0.4 0.4 192 4 203 305 69 2 71 0 -3.7 0.3 -3.3 -4.2 01/03/2005 12:00:00 11.5 0.4 12.6 10.3 11.2 0.5 12.6 9.5 0.4 0 0.4 0.4 189 2 198 305 66 0 66 0 -4.2 0 -4 -4.5 01/03/2005 12:10:00 11.9 0.5 13.3 10.3 11.4 0.7 13 8.8 0.4 0 0.4 0.4 192 3 188 305 66 0 66 0 -4.2 0 -3.8 -4.5 01/03/2005 12:20:00 11.5 0.5 13 10.3 11 0.6 12.6 8 0.4 0 0.4 0.4 192 3 189 305 66 1 66 0 -4.2 0.1 -3.8 -4.5 01/03/2005 12:30:00 11.5 0.3 12.6 9.9 11.4 0.5 13 9.9 0.4 0 0.4 0.4 188 2 190 305 65 0 65 0 -4.1 0 -3.8 -4.5 01/03/2005 12:40:00 11.2 0.4 12.2 9.9 11.1 0.5 12.2 9.5 0.4 0 0.4 0.4 189 2 189 305 64 1 65 0 -4.1 0.1 -4 -4.5 01/03/2005 12:50:00 11.3 0.4 12.2 9.9 11.2 0.6 12.6 9.1 0.4 0 0.4 0.4 188 2 192 305 63 0 63 0 -4.1 0 -3.8 -4.2 01/03/2005 13:00:00 11.4 0.4 12.6 10.3 11.1 0.5 12.2 9.5 0.4 0 0.4 0.4 189 2 190 305 62 0 63 0 -4.1 0 -4 -4.2 01/03/2005 13:10:00 11.5 0.6 13.3 9.9 11 0.6 13 9.5 0.4 0 0.4 0.4 187 3 189 305 61 0 61 0 -4.3 0 -4 -4.5 01/03/2005 13:20:00 12.5 0.6 14.1 10.3 12.1 0.7 13.7 9.9 0.4 0 0.4 0.4 188 3 190 305 61 0 61 0 -4.2 0 -4 -4.2 01/03/2005 13:30:00 12 0.5 13 10.3 11.6 0.6 13.3 9.5 0.4 0 0.4 0.4 188 3 185 305 60 0 60 0 -4.2 0 -4 -4.5 01/03/2005 13:40:00 12.5 0.5 13.7 10.7 12.2 0.7 14.1 8.8 0.4 0 0.4 0.4 187 3 188 305 61 0 61 0 -4.1 0 -3.8 -4.2 01/03/2005 13:50:00 12.1 0.5 13.7 11.1 11.8 0.6 13.7 9.9 0.4 0 0.4 0.4 188 2 191 305 61 0 61 0 -4 0 -3.8 -4 01/03/2005 14:00:00 11.9 0.5 13 9.9 11.8 0.6 13.3 8.8 0.4 0 0.4 0.4 187 2 188 305 61 1 60 0 -3.9 0 -3.6 -4 01/03/2005 14:10:00 11.5 0.4 12.6 9.9 11.3 0.5 12.6 9.9 0.4 0 0.4 0.4 188 2 186 305 62 0 62 0 -3.9 0 -3.8 -4 01/03/2005 14:20:00 11.2 0.5 12.6 9.5 10.8 0.6 12.2 9.1 0.4 0 0.4 0.4 187 3 184 305 60 0 61 0 -3.9 0 -3.8 -4 01/03/2005 14:30:00 12 0.8 13.7 10.3 12.1 0.8 13.7 9.1 0.4 0 0.4 0.4 184 3 186 305 61 0 60 0 -3.6 0 -3.3 -3.8 01/03/2005 14:40:00 13.1 1.2 16.4 8.8 14 1.1 16.8 11.1 0.4 0 0.4 0.4 182 4 181 305 67 2 69 0 -2.7 0.3 -2.4 -3.6 01/03/2005 14:50:00 13.8 1.4 16.8 8.8 14.9 1.1 17.6 11.8 0.4 0 0.4 0.4 181 5 181 305 69 0 69 0 -2.7 0 -2.4 -2.7 01/03/2005 15:00:00 13.5 0.9 15.6 10.7 14.2 0.8 16.4 11.5 0.4 0 0.4 0.4 182 4 183 305 67 2 68 0 -2.8 0 -2.7 -3.1 01/03/2005 15:10:00 13.4 0.8 14.9 10.7 13.7 0.8 15.6 11.1 0.4 0 0.4 0.4 184 3 182 305 62 1 64 0 -3.1 0.1 -2.9 -3.3 01/03/2005 15:20:00 12.5 0.7 14.1 9.5 12.7 0.7 14.9 11.1 0.4 0 0.4 0.4 184 3 186 305 57 2 54 0 -3.5 0.1 -3.1 -3.8 01/03/2005 15:30:00 13.1 0.8 15.6 10.3 13.3 0.7 15.3 11.8 0.4 0 0.4 0.4 184 3 188 305 54 0 54 0 -3.5 0 -3.3 -3.8 01/03/2005 15:40:00 13.6 1 16.4 11.1 14.3 0.9 16.8 12.6 0.4 0 0.4 0.4 182 4 184 305 58 2 59 0 -3.1 0.1 -2.7 -3.6 01/03/2005 15:50:00 13.8 1 16.1 10.3 14.5 0.9 16.4 11.8 0.4 0 0.4 0.4 181 4 181 305 60 1 59 0 -2.9 0 -2.7 -3.1 01/03/2005 16:00:00 13.6 1.3 16.8 9.5 14.9 1 17.9 12.2 0.4 0 0.4 0.4 180 5 184 305 63 1 64 0 -2.6 0.1 -2.4 -2.7 01/03/2005 16:10:00 14 1.3 16.8 9.5 15.2 1 17.9 12.2 0.4 0 0.4 0.4 180 4 181 305 64 0 65 0 -2.6 0 -2.4 -2.7 01/03/2005 16:20:00 14.6 1.1 16.8 10.3 15.5 1 17.9 12.2 0.4 0 0.4 0.4 181 4 180 305 64 0 63 0 -2.7 0 -2.2 -2.7 01/03/2005 16:30:00 15.2 1.6 19.1 10.3 16.1 1.3 19.5 12.6 0.4 0 0.4 0.4 181 4 181 305 65 1 65 0 -2.5 0.1 -2.2 -2.7 01/03/2005 16:40:00 15.8 1.3 19.5 12.6 16.3 1.2 19.5 13.7 0.4 0 0.4 0.4 182 4 186 305 63 2 65 0 -2.5 0.1 -2.2 -2.7 01/03/2005 16:50:00 16.8 1.7 21 12.2 17 1.5 21.8 13.7 0.4 0 0.4 0.4 184 4 188 305 62 1 63 0 -2.6 0 -2 -2.7 01/03/2005 17:00:00 19.4 1.7 24.4 14.9 18.5 1.7 22.9 14.1 0.4 0 0.4 0.4 195 6 199 305 66 2 67 0 -2.8 0 -2.2 -3.1 01/03/2005 17:10:00 19.1 1.5 22.9 15.6 18.2 1.7 22.1 14.1 0.4 0 0.4 0.4 198 4 202 305 69 1 68 0 -3 0 -2.9 -3.1 01/03/2005 17:20:00 18.7 1.2 22.9 15.6 18 1.3 22.6 14.5 0.4 0 0.4 0.4 202 5 202 305 71 0 71 0 -2.8 0 -2.7 -3.1 01/03/2005 17:30:00 19.3 1.6 23.3 14.9 18.7 1.6 22.6 14.5 0.4 0 0.4 0.4 204 5 212 305 70 1 69 0 -3.1 0.1 -2.7 -3.3 01/03/2005 17:40:00 18.5 1.6 22.9 15.3 17.9 1.7 22.1 13.3 0.4 0 0.4 0.4 205 4 213 305 68 0 68 0 -3.3 0 -3.1 -3.3 01/03/2005 17:50:00 18 1.7 23.7 13.3 16.9 1.9 22.6 12.6 0.4 0 0.4 0.4 210 5 203 305 69 0 69 0 -3.3 0 -3.1 -3.6 01/03/2005 18:00:00 18.9 1.6 24 13.3 18 1.8 22.1 12.2 0.4 0 0.4 0.4 216 5 214 305 68 0 68 0 -3.6 0 -3.3 -3.8 01/03/2005 18:10:00 18.4 1.6 22.1 14.1 17.1 1.8 21.4 12.6 0.4 0 0.4 0.4 221 6 223 305 68 0 67 0 -3.6 0 -3.3 -3.8 01/03/2005 18:20:00 18.5 2.1 24 13.3 17.3 2.2 22.9 12.6 0.4 0 0.4 0.4 223 5 228 305 68 0 68 0 -3.6 0 -3.1 -3.8 01/03/2005 18:30:00 18.3 2.1 24 13.7 17.1 2.2 22.1 12.2 0.4 0 0.4 0.4 225 6 219 305 66 1 67 0 -3.6 0 -3.3 -3.8 01/03/2005 18:40:00 18.4 1.5 22.1 14.1 17.3 1.6 21 12.6 0.4 0 0.4 0.4 230 6 242 305 65 0 65 0 -3.6 0 -3.3 -3.8 01/03/2005 18:50:00 17 2 21 11.5 15.7 2 19.9 9.1 0.4 0 0.4 0.4 233 5 232 305 64 1 64 0 -3.6 0 -3.3 -3.8 01/03/2005 19:00:00 17.5 1.5 20.6 11.5 16.4 1.5 19.5 11.5 0.4 0 0.4 0.4 234 5 242 305 61 0 62 0 -3.9 0 -3.6 -4 01/03/2005 19:10:00 14.8 1.8 18.3 10.3 13.7 1.9 18.3 9.1 0.4 0 0.4 0.4 236 6 232 305 61 0 61 0 -4.1 0.1 -3.8 -4.5 01/03/2005 19:20:00 15.3 1.5 18.3 11.1 14.3 1.6 17.6 9.9 0.4 0 0.4 0.4 238 5 237 305 61 0 60 0 -4.4 0 -4.2 -4.5 01/03/2005 19:30:00 14.3 1.7 18.7 9.9 13.4 1.7 17.6 8.8 0.4 0 0.4 0.4 237 5 236 305 62 1 62 0 -4.4 0 -4 -4.5 01/03/2005 19:40:00 13.5 1.5 17.2 10.3 12.5 1.5 16.8 8.8 0.4 0 0.4 0.4 238 6 241 305 63 0 63 0 -4.4 0 -4.2 -4.7 01/03/2005 19:50:00 13.7 1.3 16.8 9.9 12.8 1.4 16.4 8.8 0.4 0 0.4 0.4 235 5 233 305 64 0 64 0 -4.4 0 -4.2 -4.5 01/03/2005 20:00:00 13.1 1.7 16.8 9.1 12.2 1.6 16.4 8.4 0.4 0 0.4 0.4 239 5 246 305 63 1 63 0 -4.3 0 -3.8 -4.5 01/03/2005 20:10:00 11.2 1.4 14.1 7.6 10.4 1.4 13.7 7.2 0.4 0 0.4 0.4 236 6 239 305 64 0 64 0 -4.4 0 -4 -4.5 01/03/2005 20:20:00 12.7 1.1 15.3 9.9 11.8 1.2 14.5 8 0.4 0 0.4 0.4 236 5 242 305 64 0 64 0 -4.4 0 -4 -4.5 01/03/2005 20:30:00 12.4 1.2 15.3 8 11.5 1.3 14.9 8 0.4 0 0.4 0.4 237 5 227 305 63 1 64 0 -4.4 0 -4.5 -4.7 01/03/2005 20:40:00 12.3 1.4 15.3 8 11.5 1.5 14.9 7.6 0.4 0 0.4 0.4 239 5 236 305 63 0 64 0 -4.4 0 -4 -4.7 01/03/2005 20:50:00 12.2 1 14.1 8.8 11.3 1.2 13.7 7.6 0.4 0 0.4 0.4 237 5 237 305 62 1 63 0 -4.5 0 -4 -4.7 01/03/2005 21:00:00 11.6 1.2 14.1 7.6 10.8 1.2 13 7.2 0.4 0 0.4 0.4 234 5 227 305 62 0 63 0 -4.6 0 -4.5 -4.7 01/03/2005 21:10:00 11.6 1.3 14.5 8 10.8 1.4 14.1 7.2 0.4 0 0.4 0.4 232 5 233 305 63 1 63 0 -4.5 0 -4.2 -4.7 01/03/2005 21:20:00 11.5 1.1 13.7 8.8 10.8 1.2 13.3 7.6 0.4 0 0.4 0.4 228 5 227 305 64 1 64 0 -4.5 0 -4.2 -4.7 01/03/2005 21:30:00 10.4 1 12.2 7.6 9.5 1.1 11.8 6.8 0.4 0 0.4 0.4 234 5 235 305 64 1 65 0 -4.5 0 -4.5 -4.7 01/03/2005 21:40:00 10.7 1 12.6 7.6 9.9 1.1 12.2 6.8 0.4 0 0.4 0.4 233 5 226 305 67 1 66 0 -4.4 0 -4.2 -4.7 01/03/2005 21:50:00 10 1 12.2 7.2 9.4 1.1 11.5 6.5 0.4 0 0.4 0.4 231 5 227 305 65 0 65 0 -4.5 0 -4.2 -4.7 01/03/2005 22:00:00 8.8 0.7 10.7 6.8 8.1 0.8 10.3 6.1 0.4 0 0.4 0.4 230 7 234 305 66 1 66 0 -4.4 0 -4.2 -4.5 01/03/2005 22:10:00 9.7 0.8 11.5 7.6 9 1 10.7 6.1 0.4 0 0.4 0.4 235 5 234 305 66 1 67 0 -4.4 0 -4 -4.5 01/03/2005 22:20:00 8.4 1 10.7 5.7 7.7 1 9.9 4.9 0.4 0 0.4 0.4 235 5 231 305 66 0 66 0 -4.4 0 -4.2 -4.5 01/03/2005 22:30:00 8.9 0.8 11.5 6.8 8.5 0.9 11.1 5.7 0.4 0 0.4 0.4 239 7 239 305 66 1 67 0 -4.4 0 -4.2 -4.5 01/03/2005 22:40:00 8.1 0.7 9.9 6.1 7.5 0.9 9.9 4.9 0.4 0 0.4 0.4 243 4 241 305 65 0 64 0 -4.4 0 -4.2 -4.7 01/03/2005 22:50:00 6.7 0.7 8 4.6 6.2 0.8 8.4 4.2 0.4 0 0.4 0.4 241 6 243 305 67 1 66 0 -4.4 0 -4.2 -4.5 01/03/2005 23:00:00 7.2 0.9 9.1 4.9 6.8 1 9.5 4.2 0.4 0 0.4 0.4 230 5 229 305 69 0 69 0 -4.2 0 -4 -4.5 01/03/2005 23:10:00 7.5 0.7 8.8 5.3 7.1 0.8 8.8 4.9 0.4 0 0.4 0.4 229 4 226 305 68 0 69 0 -4.4 0 -4 -4.5 01/03/2005 23:20:00 8.3 0.8 9.9 6.1 7.6 0.9 9.5 4.6 0.4 0 0.4 0.4 237 4 238 305 69 1 71 0 -4.2 0.1 -4 -4.5 01/03/2005 23:30:00 7.2 1 9.1 4.6 6.6 1.1 8.8 4.2 0.4 0 0.4 0.4 239 5 242 305 67 0 67 0 -4.4 0 -4.2 -4.5 01/03/2005 23:40:00 7.2 0.6 8.4 5.3 6.5 0.7 8.4 4.9 0.4 0 0.4 0.4 236 4 238 305 66 0 66 0 -4.3 0 -4.2 -4.5 01/03/2005 23:50:00 6.8 0.6 8 4.9 6.1 0.7 7.6 4.2 0.4 0 0.4 0.4 235 4 233 305 66 0 66 0 -4.2 0 -4 -4.5 01/04/2005 00:00:00 5.9 0.6 7.2 4.2 5.4 0.6 7.2 4.2 0.4 0 0.4 0.4 233 4 229 305 66 0 66 0 -4.2 0 -3.8 -4.5 01/04/2005 00:10:00 5.9 0.6 7.2 4.6 5.4 0.6 6.8 3.8 0.4 0 0.4 0.4 232 4 232 305 66 0 66 0 -4.2 0 -4 -4.5 01/04/2005 00:20:00 5.5 0.6 6.8 4.2 5.1 0.5 6.5 3.4 0.4 0 0.4 0.4 232 3 228 305 68 1 67 0 -4.1 0 -4 -4.2 01/04/2005 00:30:00 5.6 0.8 7.2 4.2 5.2 0.8 6.8 3.4 0.4 0 0.4 0.4 227 5 236 305 70 0 70 0 -4 0 -3.8 -4 01/04/2005 00:40:00 5.9 0.5 6.8 4.6 5.4 0.5 6.5 4.2 0.4 0 0.4 0.4 231 4 229 305 70 0 70 0 -3.9 0 -3.6 -4 01/04/2005 00:50:00 5.7 0.4 6.8 4.6 5.3 0.5 6.5 3.8 0.4 0 0.4 0.4 229 3 224 305 70 0 71 0 -3.9 0 -3.6 -4 01/04/2005 01:00:00 5.4 0.5 6.5 4.2 4.9 0.5 6.1 3.8 0.4 0 0.4 0.4 225 4 229 305 70 0 70 0 -3.9 0 -3.3 -4 01/04/2005 01:10:00 4.8 0.4 6.1 3 4.6 0.5 6.1 3.4 0.4 0 0.4 0.4 209 7 205 305 71 0 72 0 -3.9 0 -3.3 -4 01/04/2005 01:20:00 4.7 0.4 5.7 3.8 4.6 0.4 5.7 3.8 0.4 0 0.4 0.4 199 3 204 305 71 0 71 0 -4 0 -3.3 -4 01/04/2005 01:30:00 4.2 0.5 5.7 2.6 4.3 0.5 5.7 3 0.4 0 0.4 0.4 194 6 205 305 72 1 72 0 -3.9 0 -3.8 -4 01/04/2005 01:40:00 4.3 0.3 4.9 3 4.4 0.3 4.9 3.4 0.4 0 0.4 0.4 192 4 197 305 73 0 73 0 -3.9 0 -3.8 -4 01/04/2005 01:50:00 4.4 0.2 4.9 3.8 4.5 0.2 4.9 4.2 0.4 0 0.4 0.4 191 3 193 305 73 1 72 0 -3.9 0 -3.6 -3.8 01/04/2005 02:00:00 4.4 0.3 4.9 3.4 4.7 0.3 5.3 4.2 0.4 0 0.4 0.4 188 3 190 305 76 0 76 0 -3.7 0 -3.3 -3.8 01/04/2005 02:10:00 4.9 0.2 5.3 3.8 5.2 0.2 5.7 4.9 0.4 0 0.4 0.4 186 2 186 305 78 1 77 0 -3.5 0 -3.3 -3.8 01/04/2005 02:20:00 5.3 0.3 6.1 4.6 5.6 0.3 6.5 4.9 0.4 0 0.4 0.4 186 2 180 305 79 0 79 0 -3.3 0 -2.9 -3.6 01/04/2005 02:30:00 5.7 0.3 6.5 4.6 6 0.4 6.8 4.9 0.4 0 0.4 0.4 187 2 189 305 75 1 74 0 -3.6 0.1 -3.1 -3.8 01/04/2005 02:40:00 6 0.2 6.5 5.3 6.2 0.2 6.5 5.3 0.4 0 0.4 0.4 186 2 190 305 74 0 73 0 -3.6 0 -3.3 -3.8 01/04/2005 02:50:00 5.7 0.6 7.2 3.4 6.2 0.4 7.6 4.9 0.4 0 0.4 0.4 183 3 190 305 75 1 75 0 -3.5 0.2 -2.7 -3.8 01/04/2005 03:00:00 7.4 1.3 9.1 3.8 8 0.9 9.5 5.7 0.4 0 0.4 0.4 183 4 186 305 80 2 82 0 -3 0.1 -2.7 -3.3 01/04/2005 03:10:00 8.5 0.2 9.1 8 8.7 0.2 9.5 8 0.4 0 0.4 0.4 189 2 193 305 80 0 79 0 -3.1 0 -3.1 -3.3 01/04/2005 03:20:00 8.6 0.4 9.9 7.6 8.9 0.3 9.9 8 0.4 0 0.4 0.4 189 2 190 305 78 1 78 0 -3.3 0 -3.1 -3.6 01/04/2005 03:30:00 8.8 0.6 10.3 7.6 8.8 0.5 9.9 7.6 0.4 0 0.4 0.4 191 2 193 305 74 1 74 0 -3.7 0.1 -3.3 -4 01/04/2005 03:40:00 9.7 0.2 10.3 9.1 9.6 0.2 10.3 9.1 0.4 0 0.4 0.4 192 1 192 305 74 0 74 0 -3.8 0 -3.6 -3.8 01/04/2005 03:50:00 9.8 0.3 10.7 9.1 9.6 0.2 10.7 9.1 0.4 0 0.4 0.4 194 1 196 305 74 0 74 0 -3.8 0 -3.6 -4 01/04/2005 04:00:00 9.7 0.3 10.3 9.1 9.5 0.2 10.3 8.8 0.4 0 0.4 0.4 194 1 194 305 74 0 74 0 -3.8 0 -3.8 -3.8 01/04/2005 04:10:00 9.9 0.3 11.5 9.1 9.8 0.3 11.5 9.1 0.4 0 0.4 0.4 193 1 197 305 76 1 76 0 -3.6 0 -3.3 -3.8 01/04/2005 04:20:00 9.8 0.2 10.3 9.1 9.6 0.3 10.3 8.8 0.4 0 0.4 0.4 194 1 191 305 76 0 77 0 -3.6 0 -3.3 -3.8 01/04/2005 04:30:00 9.9 0.3 10.7 9.1 9.8 0.3 11.1 8.8 0.4 0 0.4 0.4 195 1 197 305 76 0 77 0 -3.3 0 -3.3 -3.6 01/04/2005 04:40:00 9.5 0.4 10.7 8.8 9.5 0.3 10.7 8.8 0.4 0 0.4 0.4 196 2 196 305 77 0 76 0 -3.2 0 -3.1 -3.3 01/04/2005 04:50:00 9.2 0.3 9.9 8.4 9.2 0.3 10.3 8.4 0.4 0 0.4 0.4 197 3 198 305 77 0 77 0 -3.1 0 -2.9 -3.3 01/04/2005 05:00:00 9.1 0.3 10.3 8.4 8.9 0.4 9.9 7.2 0.4 0 0.4 0.4 199 2 203 305 77 0 77 0 -3 0 -2.7 -3.1 01/04/2005 05:10:00 9.5 0.4 10.7 8.4 9.3 0.4 10.3 7.6 0.4 0 0.4 0.4 197 2 198 305 76 0 75 0 -3.1 0 -2.9 -3.3 01/04/2005 05:20:00 9.8 0.3 10.7 9.1 9.6 0.3 10.7 8 0.4 0 0.4 0.4 196 2 198 305 72 2 71 0 -3.4 0.1 -3.1 -3.6 01/04/2005 05:30:00 9.7 0.3 10.7 8.8 9.5 0.4 10.7 8 0.4 0 0.4 0.4 197 2 195 305 70 0 71 0 -3.5 0 -3.3 -3.8 01/04/2005 05:40:00 9.7 0.2 10.3 9.1 9.6 0.3 10.3 8 0.4 0 0.4 0.4 195 1 194 305 70 0 70 0 -3.6 0 -3.3 -3.8 01/04/2005 05:50:00 10.2 0.4 11.5 9.5 10.1 0.3 11.1 9.1 0.4 0 0.4 0.4 195 2 196 305 73 1 74 0 -3.3 0 -3.1 -3.6 01/04/2005 06:00:00 10 0.3 11.1 9.1 9.9 0.3 11.1 8.8 0.4 0 0.4 0.4 195 2 194 305 73 0 74 0 -3.3 0 -3.1 -3.6 01/04/2005 06:10:00 9.9 0.3 10.7 9.1 9.8 0.3 10.7 8.8 0.4 0 0.4 0.4 195 2 195 305 74 0 74 0 -3.3 0 -3.1 -3.6 01/04/2005 06:20:00 9.9 0.3 11.1 9.1 9.8 0.4 11.5 8 0.4 0 0.4 0.4 194 2 195 305 73 0 73 0 -3.4 0 -3.3 -3.6 01/04/2005 06:30:00 10 0.3 10.7 9.1 10 0.3 11.1 9.1 0.4 0 0.4 0.4 194 2 194 305 73 0 73 0 -3.5 0 -3.3 -3.8 01/04/2005 06:40:00 9.7 0.3 10.7 9.1 9.8 0.3 10.7 9.1 0.4 0 0.4 0.4 194 2 196 305 72 0 72 0 -3.6 0 -3.3 -3.8 01/04/2005 06:50:00 9.8 0.3 10.7 9.1 9.9 0.3 10.7 8.8 0.4 0 0.4 0.4 194 2 199 305 73 0 73 0 -3.5 0 -3.3 -3.8 01/04/2005 07:00:00 9.9 0.3 11.5 9.1 10 0.3 11.1 8 0.4 0 0.4 0.4 194 2 195 305 74 0 74 0 -3.4 0 -3.3 -3.6 01/04/2005 07:10:00 9.8 0.3 10.7 9.1 9.8 0.3 10.7 8.8 0.4 0 0.4 0.4 195 2 196 305 74 0 75 0 -3.4 0 -3.3 -3.6 01/04/2005 07:20:00 9.9 0.4 11.5 9.1 10 0.3 10.7 8.8 0.4 0 0.4 0.4 194 2 197 305 74 0 74 0 -3.5 0 -3.3 -3.8 01/04/2005 07:30:00 9.5 0.4 10.7 8.8 9.8 0.3 11.1 8.8 0.4 0 0.4 0.4 193 3 194 305 73 0 74 0 -3.6 0 -3.3 -3.8 01/04/2005 07:40:00 9.4 0.4 10.7 8.4 9.6 0.3 10.7 8.4 0.4 0 0.4 0.4 192 2 192 305 74 0 73 0 -3.5 0 -3.3 -3.8 01/04/2005 07:50:00 9.5 0.3 10.3 8.8 9.8 0.3 10.7 9.1 0.4 0 0.4 0.4 191 2 192 305 73 0 73 0 -3.6 0 -3.3 -3.8 01/04/2005 08:00:00 9.9 0.2 10.7 9.1 10.1 0.2 11.1 9.5 0.4 0 0.4 0.4 193 1 194 305 74 0 74 0 -3.6 0 -3.3 -3.8 01/04/2005 08:10:00 10.5 0.3 11.1 9.9 10.7 0.3 11.5 9.5 0.4 0 0.4 0.4 192 1 193 305 74 0 74 0 -3.7 0 -3.6 -3.8 01/04/2005 08:20:00 10.8 0.3 11.5 9.9 10.9 0.3 11.8 10.3 0.4 0 0.4 0.4 192 1 192 305 74 0 75 0 -3.8 0 -3.6 -3.8 01/04/2005 08:30:00 10.6 0.4 11.5 9.5 10.7 0.3 11.5 9.9 0.4 0 0.4 0.4 191 2 194 305 72 1 74 0 -4.1 0.1 -3.8 -4.5 01/04/2005 08:40:00 10.5 0.4 11.5 9.5 10.8 0.3 11.8 9.9 0.4 0 0.4 0.4 190 2 192 305 70 0 70 0 -4.4 0 -4 -4.5 01/04/2005 08:50:00 10.2 0.4 11.1 9.1 10.2 0.3 11.1 9.5 0.4 0 0.4 0.4 191 2 192 305 70 0 70 0 -4.5 0 -4.5 -4.7 01/04/2005 09:00:00 10 0.3 10.7 9.1 10.4 0.3 11.5 9.5 0.4 0 0.4 0.4 190 2 192 305 71 1 72 0 -4.5 0 -4.2 -4.7 01/04/2005 09:10:00 10.2 0.3 11.1 9.5 10.4 0.3 11.1 9.1 0.4 0 0.4 0.4 191 2 194 305 72 0 72 0 -4.4 0 -4.2 -4.5 01/04/2005 09:20:00 10.5 0.3 11.1 9.5 10.6 0.3 11.5 9.9 0.4 0 0.4 0.4 191 2 192 305 75 1 75 0 -4.2 0 -4 -4.5 01/04/2005 09:30:00 10.7 0.3 11.8 9.9 10.9 0.3 11.8 10.3 0.4 0 0.4 0.4 190 2 194 305 77 1 77 0 -4.1 0 -3.8 -4.2 01/04/2005 09:40:00 10.8 0.3 11.5 9.5 11 0.3 11.8 10.3 0.4 0 0.4 0.4 191 2 192 305 79 0 79 0 -3.9 0 -3.8 -4 01/04/2005 09:50:00 11 0.3 11.8 9.9 11.4 0.3 12.2 9.9 0.4 0 0.4 0.4 191 2 192 305 81 0 81 0 -3.8 0 -3.6 -3.8 01/04/2005 10:00:00 11.1 0.4 12.2 9.5 11.6 0.4 12.6 10.3 0.4 0 0.4 0.4 189 3 193 305 82 0 82 0 -3.7 0 -3.3 -3.8 01/04/2005 10:10:00 11.5 1 15.3 9.1 11.7 0.8 14.5 9.9 0.4 0 0.4 0.4 194 9 205 305 85 2 87 0 -3.3 0.2 -2.4 -3.8 01/04/2005 10:20:00 11.9 1 14.9 9.1 11.1 1.2 14.1 8 0.4 0 0.4 0.4 216 7 212 305 90 1 91 0 -2.6 0.1 -2 -2.7 01/04/2005 10:30:00 10.9 1 13.3 7.6 10.2 1 12.6 7.6 0.4 0 0.4 0.4 225 5 228 305 92 0 92 0 -2.7 0 -2.4 -2.9 01/04/2005 10:40:00 10.7 2 15.3 7.2 9.8 2 14.5 6.1 0.4 0 0.4 0.4 255 23 285 305 90 3 86 0 -3 0.4 -2.2 -4 01/04/2005 10:50:00 11.8 1.3 14.9 8.8 11.2 1.4 14.1 7.6 0.4 0 0.4 0.4 288 7 295 305 71 5 78 0 -4.9 0.3 -3.8 -5.3 01/04/2005 11:00:00 9.9 1 12.2 7.2 9.4 1 11.8 6.8 0.4 0 0.4 0.4 287 10 279 305 62 1 64 0 -5.4 0 -5.1 -5.6 01/04/2005 11:10:00 9.3 0.9 12.2 7.2 8.4 1 10.7 6.1 0.4 0 0.4 0.4 283 13 280 305 60 0 60 0 -5.5 0 -5.1 -5.6 01/04/2005 11:20:00 9.6 1.4 14.1 6.1 7.9 1.4 12.2 4.6 0.4 0 0.4 0.4 272 8 275 305 62 0 62 0 -5.1 0 -4.9 -5.3 01/04/2005 11:30:00 8.2 1.2 11.8 4.9 6.5 1 9.9 4.2 0.4 0 0.4 0.4 269 8 274 305 62 0 62 0 -5.2 0 -4.9 -5.3 01/04/2005 11:40:00 8.4 1.3 11.5 4.9 6.7 1.2 9.5 3.8 0.4 0 0.4 0.4 269 7 277 305 62 0 62 0 -5.2 0 -5.1 -5.3 01/04/2005 11:50:00 7.5 1 9.5 4.6 6.2 1 8.4 3.8 0.4 0 0.4 0.4 273 7 262 305 61 0 62 0 -5.2 0 -5.1 -5.6 01/04/2005 12:00:00 6.9 0.7 8.8 4.6 5.5 0.8 7.6 3.8 0.4 0 0.4 0.4 271 6 287 305 61 0 62 0 -5.3 0 -5.1 -5.6 01/04/2005 12:10:00 6.5 1.1 8.8 3.8 5.2 0.9 7.6 3 0.4 0 0.4 0.4 268 6 273 305 62 0 62 0 -5.2 0 -5.1 -5.3 01/04/2005 12:20:00 7.3 1.1 9.9 4.6 5.8 1 8 2.6 0.4 0 0.4 0.4 265 6 262 305 63 0 63 0 -5.1 0 -4.9 -5.3 01/04/2005 12:30:00 6.7 1 9.1 4.2 5.4 1 8 3 0.4 0 0.4 0.4 263 6 258 305 64 0 64 0 -5 0 -4.9 -5.1 01/04/2005 12:40:00 6.2 0.8 8.8 4.6 5.1 0.7 7.6 3.4 0.4 0 0.4 0.4 272 7 268 305 64 0 64 0 -5 0 -4.7 -5.1 01/04/2005 12:50:00 5.9 0.8 7.6 3.4 4.8 0.7 6.5 2.6 0.4 0 0.4 0.4 272 8 268 305 63 1 62 0 -5 0 -4.7 -5.1 01/04/2005 13:00:00 5 0.6 6.5 3.4 4.5 0.5 6.1 3 0.4 0 0.4 0.4 251 8 252 305 62 0 62 0 -5 0 -4.9 -5.1 01/04/2005 13:10:00 5.3 0.5 6.5 4.2 4.9 0.5 6.1 3.8 0.4 0 0.4 0.4 236 9 246 305 61 0 62 0 -5.1 0 -4.9 -5.1 01/04/2005 13:20:00 5.4 0.4 6.5 3.8 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 220 4 223 305 61 0 60 0 -5.3 0.1 -5.1 -5.6 01/04/2005 13:30:00 6.6 0.6 8.4 4.9 6.1 0.7 7.6 4.6 0.4 0 0.4 0.4 222 4 227 305 60 0 60 0 -5.4 0 -5.1 -5.6 01/04/2005 13:40:00 7.7 0.9 9.5 6.1 7.1 0.9 9.9 5.3 0.4 0 0.4 0.4 219 5 217 305 62 1 62 0 -5.1 0.2 -4.7 -5.3 01/04/2005 13:50:00 8.3 0.7 10.3 6.1 7.5 0.8 9.9 5.3 0.4 0 0.4 0.4 222 5 211 305 66 1 67 0 -4.6 0 -4.5 -4.7 01/04/2005 14:00:00 8.6 0.8 10.3 6.1 7.9 0.9 9.9 4.9 0.4 0 0.4 0.4 224 4 228 305 68 0 68 0 -4.5 0 -4.2 -4.7 01/04/2005 14:10:00 8.1 0.9 10.7 5.7 7.5 1 10.7 5.3 0.4 0 0.4 0.4 226 5 222 305 70 0 69 0 -4.4 0 -4.2 -4.5 01/04/2005 14:20:00 7.7 0.8 9.5 5.7 7.1 0.8 9.1 4.9 0.4 0 0.4 0.4 222 5 221 305 69 0 69 0 -4.4 0 -4.2 -4.5 01/04/2005 14:30:00 8.3 0.8 9.9 6.5 7.7 0.9 9.5 5.7 0.4 0 0.4 0.4 221 5 223 305 69 0 69 0 -4.4 0 -4.2 -4.5 01/04/2005 14:40:00 8.2 0.8 10.3 5.7 7.8 0.8 9.9 5.3 0.4 0 0.4 0.4 220 5 222 305 69 0 68 0 -4.3 0 -4.2 -4.5 01/04/2005 14:50:00 8.6 0.7 9.9 6.8 7.9 0.9 9.9 6.1 0.4 0 0.4 0.4 227 5 230 305 70 0 70 0 -4.2 0 -4 -4.5 01/04/2005 15:00:00 7.9 0.7 9.1 5.7 7.4 0.8 9.1 4.6 0.4 0 0.4 0.4 230 4 227 305 70 0 70 0 -4.4 0 -4.2 -4.5 01/04/2005 15:10:00 6.8 0.8 8.4 4.9 6.3 0.8 8.8 4.6 0.4 0 0.4 0.4 235 6 231 305 71 0 72 0 -4.4 0 -4.2 -4.5 01/04/2005 15:20:00 6.7 1 9.1 4.2 5.3 0.9 8.4 3.4 0.4 0 0.4 0.4 265 7 259 305 71 1 72 0 -4.6 0.1 -4.2 -4.9 01/04/2005 15:30:00 7.4 0.8 8.8 4.6 6 1 8.8 3.8 0.4 0 0.4 0.4 260 7 263 305 68 1 67 0 -4.9 0 -4.7 -5.1 01/04/2005 15:40:00 6.2 0.9 8.8 4.2 5.7 0.9 8 3 0.4 0 0.4 0.4 250 8 254 305 66 0 67 0 -4.9 0 -4.7 -5.1 01/04/2005 15:50:00 6.5 1 8.8 4.2 6.1 1 8 3.4 0.4 0 0.4 0.4 240 7 242 305 66 0 66 0 -4.8 0 -4.7 -4.9 01/04/2005 16:00:00 7.5 1 10.3 5.3 7 1 9.5 4.9 0.4 0 0.4 0.4 235 5 238 305 66 0 66 0 -4.6 0 -4.5 -4.7 01/04/2005 16:10:00 8.5 1.1 10.7 6.1 7.8 1.1 10.3 5.3 0.4 0 0.4 0.4 235 5 238 305 63 1 63 0 -4.8 0 -4.5 -4.9 01/04/2005 16:20:00 8.6 0.8 10.7 6.1 8 0.9 10.3 6.1 0.4 0 0.4 0.4 231 5 234 305 61 0 61 0 -4.9 0 -4.7 -5.1 01/04/2005 16:30:00 8.1 0.8 9.5 6.1 7.4 0.9 9.1 4.9 0.4 0 0.4 0.4 228 5 230 305 60 0 60 0 -5 0 -4.7 -5.1 01/04/2005 16:40:00 8.2 0.8 10.3 6.1 7.5 0.8 9.5 5.3 0.4 0 0.4 0.4 225 5 224 305 59 0 59 0 -5 0 -4.9 -5.1 01/04/2005 16:50:00 7.6 0.7 9.5 5.3 7 0.7 8.8 4.9 0.4 0 0.4 0.4 217 5 214 305 59 0 60 0 -5 0 -4.9 -5.1 01/04/2005 17:00:00 7.1 0.6 9.1 5.3 6.7 0.7 8.4 4.6 0.4 0 0.4 0.4 214 4 223 305 59 0 59 0 -5 0 -4.9 -5.1 01/04/2005 17:10:00 7.7 0.6 9.1 6.1 7.1 0.7 9.1 4.9 0.4 0 0.4 0.4 211 5 198 305 60 0 60 0 -4.9 0 -4.7 -5.1 01/04/2005 17:20:00 7.3 0.6 9.1 5.3 7 0.6 8.8 5.3 0.4 0 0.4 0.4 206 5 210 305 62 1 61 0 -4.8 0 -4.7 -4.9 01/04/2005 17:30:00 7 0.8 9.5 5.3 6.7 0.7 9.1 4.9 0.4 0 0.4 0.4 196 7 206 305 65 0 64 0 -4.7 0.1 -4.5 -4.9 01/04/2005 17:40:00 7.4 1 8.8 4.2 8 0.6 9.1 6.5 0.4 0 0.4 0.4 185 4 189 305 66 1 66 0 -4.7 0.1 -4.5 -4.9 01/04/2005 17:50:00 7.6 1.1 9.9 4.2 8.6 0.7 11.1 6.8 0.4 0 0.4 0.4 182 4 180 305 69 1 71 0 -4.4 0.2 -4 -4.7 01/04/2005 18:00:00 6.2 1.2 9.5 3.8 8.5 0.9 10.7 6.5 0.4 0 0.4 0.4 175 6 185 305 71 1 70 0 -4.2 0.1 -4 -4.5 01/04/2005 18:10:00 6.2 1.2 10.3 3.8 7.8 1 10.7 5.3 0.4 0 0.4 0.4 167 8 161 305 67 2 66 0 -4.9 0.3 -4.2 -5.6 01/04/2005 18:20:00 7.5 1 9.5 4.2 7.9 1 11.1 5.7 0.4 0 0.4 0.4 159 7 155 305 63 0 63 0 -5.4 0 -5.1 -5.6 01/04/2005 18:30:00 8.6 0.8 10.7 6.5 8.3 0.7 10.3 6.5 0.4 0 0.4 0.4 151 6 147 305 64 1 65 0 -5.3 0.1 -5.1 -5.6 01/04/2005 18:40:00 8.5 1 11.5 6.1 8.2 0.8 10.7 6.1 0.4 0 0.4 0.4 148 8 142 305 70 2 69 0 -5 0.1 -4.7 -5.1 01/04/2005 18:50:00 8.8 1 11.1 5.7 8.7 1 11.1 6.1 0.4 0 0.4 0.4 143 9 144 305 73 0 73 0 -4.8 0 -4.7 -4.9 01/04/2005 19:00:00 10.7 0.7 13 8.8 10.6 0.7 12.6 8.4 0.4 0 0.4 0.4 135 5 144 305 75 1 76 0 -4.7 0 -4.5 -4.9 01/04/2005 19:10:00 11.7 0.9 13.7 8.8 11.5 0.9 13.7 8.8 0.4 0 0.4 0.4 135 5 138 305 78 1 80 0 -4.5 0 -4.2 -4.7 01/04/2005 19:20:00 12.1 1 13.7 8.8 11.8 1 14.1 8.8 0.4 0 0.4 0.4 131 5 135 305 81 0 82 0 -4.4 0 -4.2 -4.5 01/04/2005 19:30:00 12.4 1.3 15.6 8.4 12 1.3 14.5 7.6 0.4 0 0.4 0.4 132 7 140 305 84 1 84 0 -4.2 0 -4 -4.5 01/04/2005 19:40:00 13.2 1.2 16.1 10.3 13 1.1 16.1 10.3 0.4 0 0.4 0.4 136 5 136 305 88 1 87 0 -4 0 -3.8 -4.2 01/04/2005 19:50:00 14.2 1.1 16.8 11.1 13.8 1.2 16.4 10.3 0.4 0 0.4 0.4 137 5 137 305 91 1 91 0 -3.7 0 -3.6 -3.8 01/04/2005 20:00:00 14.5 1.2 17.2 11.5 14.1 1.1 17.2 11.5 0.4 0 0.4 0.4 136 6 129 305 94 1 94 0 -3.6 0 -3.3 -3.8 01/04/2005 20:10:00 15.6 1.1 17.9 12.6 15.3 1.2 18.3 12.2 0.4 0 0.4 0.4 138 6 136 305 97 1 98 0 -3.3 0 -2.7 -3.6 01/04/2005 20:20:00 14.9 1.7 19.1 11.1 14.7 1.7 18.7 9.5 0.4 0 0.4 0.4 140 8 143 305 99 1 99 0 -3.2 0.1 -2.7 -3.3 01/04/2005 20:30:00 14.9 2.1 21.4 8 14.8 1.9 21.4 9.9 0.4 0 0.4 0.4 150 10 144 305 104 2 107 0 -2.6 0.1 -2.4 -3.1 01/04/2005 20:40:00 15.7 2.4 21.8 10.3 16.4 1.9 22.6 11.5 0.4 0 0.4 0.4 158 8 159 305 110 2 112 0 -2.2 0.1 -1.8 -2.4 01/04/2005 20:50:00 16.1 2 21.4 11.8 18.3 1.3 21.8 15.3 0.4 0 0.4 0.4 162 5 163 305 115 1 114 0 -1.8 0 -1.8 -2 01/04/2005 21:00:00 15.8 1.7 21.4 11.8 18.5 1.7 23.7 14.9 0.4 0 0.4 0.4 168 8 159 305 121 3 122 0 -1.4 0.2 -1.1 -2 01/04/2005 21:10:00 17.7 1.7 22.1 13.3 17.4 1.7 21.4 12.6 0.4 0 0.4 0.4 188 5 194 305 128 1 127 0 -0.8 0.1 0.1 -1.1 01/04/2005 21:20:00 18.6 1.2 21.8 15.3 17.7 1.3 21 14.1 0.4 0 0.4 0.4 195 5 189 305 129 1 129 0 -0.5 0 0.1 -0.6 01/04/2005 21:30:00 16.9 1.2 19.5 13 16.2 1.3 19.1 11.8 0.4 0 0.4 0.4 196 4 198 305 126 1 128 0 -0.5 0 -0.4 -0.6 01/04/2005 21:40:00 16.1 1 18.7 13.7 15.4 1.1 17.9 11.8 0.4 0 0.4 0.4 197 4 197 305 125 1 126 0 -0.5 0 -0.4 -0.6 01/04/2005 21:50:00 15.4 1 18.7 12.6 14.9 1.1 17.9 12.2 0.4 0 0.4 0.4 198 3 202 305 125 0 124 0 -0.4 0 -0.4 -0.6 01/04/2005 22:00:00 15.1 1 18.3 12.2 14.6 1.1 18.3 11.5 0.4 0 0.4 0.4 203 4 213 305 124 1 123 0 -0.4 0 -0.4 -0.4 01/04/2005 22:10:00 15.1 1.1 18.3 12.6 14.4 1.2 18.3 11.5 0.4 0 0.4 0.4 205 4 203 305 124 1 122 0 -0.3 0 -0.1 -0.4 01/04/2005 22:20:00 14.9 0.9 16.8 12.2 14.3 1 16.4 11.5 0.4 0 0.4 0.4 208 4 209 305 124 0 124 0 -0.3 0 -0.1 -0.4 01/04/2005 22:30:00 15 1 17.6 12.6 14.3 1 17.2 11.8 0.4 0 0.4 0.4 207 4 208 305 124 0 124 0 -0.3 0 -0.1 -0.4 01/04/2005 22:40:00 15 1 17.9 10.7 14.3 1.1 17.2 10.7 0.4 0 0.4 0.4 206 4 203 305 122 0 122 0 -0.3 0 -0.1 -0.4 01/04/2005 22:50:00 15 1.3 17.9 11.5 13.9 1.6 17.9 10.3 0.4 0 0.4 0.4 211 5 221 305 122 0 122 0 -0.4 0 -0.1 -0.4 01/04/2005 23:00:00 14.6 1.1 17.9 11.1 13.5 1.4 16.8 9.5 0.4 0 0.4 0.4 213 4 221 305 123 0 119 0 -0.5 0 0.1 -0.6 01/04/2005 23:10:00 14 1 17.2 11.5 13.1 1.1 15.6 9.9 0.4 0 0.4 0.4 215 4 217 305 123 0 124 0 -0.6 0 -0.4 -0.6 01/04/2005 23:20:00 13 1.1 16.1 9.9 12.3 1.2 15.3 8.8 0.4 0 0.4 0.4 219 5 214 305 124 0 123 0 -0.7 0 -0.6 -1.1 01/04/2005 23:30:00 14 1.4 17.2 9.9 12.8 1.5 17.6 9.5 0.4 0 0.4 0.4 223 5 229 305 125 0 125 0 -1 0.1 -0.6 -1.1 01/04/2005 23:40:00 13.1 1.2 17.2 9.9 12.1 1.2 15.3 8.8 0.4 0 0.4 0.4 227 5 221 305 126 0 126 0 -1.2 0 -1.1 -1.3 01/04/2005 23:50:00 11.8 1.5 15.6 7.6 10.9 1.6 14.9 7.6 0.4 0 0.4 0.4 235 6 235 305 127 0 126 0 -1.2 0 -1.1 -1.5 01/05/2005 00:00:00 10.6 1.1 13 7.2 9.7 1.1 12.6 6.5 0.4 0 0.4 0.4 240 7 230 305 127 0 127 0 -1.4 0 -0.8 -1.5 01/05/2005 00:10:00 9.5 1 12.2 6.5 8.6 1.1 11.1 5.3 0.4 0 0.4 0.4 243 6 246 305 127 0 127 0 -1.5 0 -1.1 -1.8 01/05/2005 00:20:00 9.4 1.1 12.2 6.8 8.6 1.1 11.5 5.7 0.4 0 0.4 0.4 245 6 250 305 128 0 128 0 -1.5 0 -0.8 -1.5 01/05/2005 00:30:00 9.3 1 11.8 6.8 8.5 1 11.1 6.1 0.4 0 0.4 0.4 248 6 250 305 128 0 128 0 -1.4 0 -0.8 -1.5 01/05/2005 00:40:00 8.6 1.2 11.5 5.7 7.5 1 10.7 4.6 0.4 0 0.4 0.4 270 29 257 305 128 1 128 0 -1.5 0.1 -1.1 -2.2 01/05/2005 00:50:00 8.1 1.2 10.3 4.9 8.2 1.2 10.3 5.3 0.4 0 0.4 0.4 339 5 343 305 120 3 119 0 -3.8 0.6 -2.2 -4.7 01/05/2005 01:00:00 8.3 1 10.3 6.1 8.4 1 11.1 6.5 0.4 0 0.4 0.4 341 5 342 305 115 1 115 0 -4.6 0 -4.2 -4.7 01/05/2005 01:10:00 9.5 1.1 12.6 6.8 9.6 1.2 12.6 6.8 0.4 0 0.4 0.4 343 5 340 305 114 0 114 0 -4.9 0 -4.5 -5.1 01/05/2005 01:20:00 8.8 1.2 11.8 5.3 8.9 1.2 12.2 5.7 0.4 0.1 2.6 0.4 343 6 334 305 114 0 114 0 -5 0 -4.5 -5.3 01/05/2005 01:30:00 10.2 1.3 13.3 7.2 10.2 1.3 13.7 7.6 0.4 0 0.4 0.4 334 6 332 305 113 0 113 0 -5.1 0 -4.5 -5.3 01/05/2005 01:40:00 8.4 1.3 12.2 5.3 8.5 1.3 12.2 5.3 0.4 0 0.4 0.4 330 6 334 305 113 0 113 0 -5 0 -4.5 -5.1 01/05/2005 01:50:00 7.5 0.9 9.9 4.9 7.4 1 9.5 4.9 0.4 0 0.4 0.4 327 8 309 305 113 1 114 0 -4.9 0 -4.5 -5.1 01/05/2005 02:00:00 5.2 0.7 7.6 3.8 4.9 0.7 7.2 3.4 0.4 0 0.4 0.4 318 13 323 305 112 1 112 0 -4.9 0 -4.2 -5.1 01/05/2005 02:10:00 7.1 1.8 12.6 4.2 6.7 1.5 12.2 3.8 0.4 0 0.4 0.4 301 23 280 305 116 1 118 0 -4.4 0.2 -3.6 -4.7 01/05/2005 02:20:00 10.2 1.1 12.6 7.2 9.6 1 11.8 6.8 0.4 0 0.4 0.4 291 12 280 305 117 1 118 0 -4.1 0.2 -3.6 -4.5 01/05/2005 02:30:00 10.7 1.6 13.3 6.1 10.3 1.6 13 6.1 0.4 0 0.4 0.4 295 12 303 305 115 1 114 0 -4.5 0 -4 -4.7 01/05/2005 02:40:00 11.6 1.1 13.7 8 11.1 1.1 13.7 7.6 0.4 0 0.4 0.4 293 9 287 305 112 0 112 0 -4.7 0 -4.2 -4.9 01/05/2005 02:50:00 11.1 1.4 14.1 7.6 10 1.3 13 6.1 0.4 0 0.4 0.4 287 14 283 305 112 0 112 0 -4.9 0 -4.7 -5.1 01/05/2005 03:00:00 11.9 1 14.5 8 10.2 1.2 13.3 7.2 0.4 0 0.4 0.4 278 6 279 305 110 0 111 0 -5.1 0 -4.9 -5.3 01/05/2005 03:10:00 11.6 1.5 15.3 7.2 9.5 1.3 13.7 6.1 0.4 0 0.4 0.4 275 7 276 305 109 0 109 0 -5.3 0 -5.1 -5.6 01/05/2005 03:20:00 9.6 1.8 13 4.9 7.7 1.5 11.1 4.2 0.4 0 0.4 0.4 271 9 273 305 106 1 108 0 -5.4 0 -5.1 -5.6 01/05/2005 03:30:00 9.2 1.3 13 4.9 7.5 1.1 10.7 4.2 0.4 0 0.4 0.4 275 8 268 305 104 1 105 0 -5.5 0 -5.1 -5.6 01/05/2005 03:40:00 10.6 1.4 13 6.5 8.4 1.2 11.1 4.9 0.4 0 0.4 0.4 271 6 269 305 103 0 103 0 -5.3 0 -5.1 -5.6 01/05/2005 03:50:00 10.6 1.2 13 7.6 8.4 1.2 12.2 5.3 0.4 0 0.4 0.4 265 6 269 305 103 0 103 0 -5.4 0 -5.1 -5.6 01/05/2005 04:00:00 10.2 1.2 12.2 6.5 8.4 1.3 11.8 5.7 0.4 0 0.4 0.4 260 7 261 305 102 1 101 0 -5.5 0 -5.1 -5.8 01/05/2005 04:10:00 9.7 1.2 11.8 6.5 8.6 1.3 11.8 4.6 1.2 1.4 6.1 0.4 255 7 260 305 100 0 99 0 -5.7 0 -5.1 -5.8 01/05/2005 04:20:00 8.6 1.4 11.1 4.9 7.7 1.5 11.1 4.6 0.4 0 0.4 0.4 255 6 257 305 99 0 99 0 -5.8 0 -5.6 -6 01/05/2005 04:30:00 8.5 1.2 10.7 5.3 7.2 1.2 9.5 3.4 0.4 0 0.4 0.4 257 8 261 305 98 0 98 0 -5.9 0 -5.8 -6 01/05/2005 04:40:00 9.4 1 11.8 6.5 8.3 1.2 10.7 5.3 0.4 0 0.4 0.4 254 6 252 305 97 1 97 0 -6 0 -5.8 -6.2 01/05/2005 04:50:00 9.2 1.2 11.5 6.1 8 1.2 11.5 4.9 0.4 0 0.4 0.4 255 8 265 305 96 0 96 0 -6.1 0 -6 -6.2 01/05/2005 05:00:00 10.2 1.1 12.6 6.8 9.5 1.2 12.2 6.1 0.7 1.1 6.8 0.4 247 6 249 305 95 0 95 0 -6.1 0 -5.8 -6.2 01/05/2005 05:10:00 10 1.3 12.6 6.5 9.2 1.5 12.2 5.7 0.4 0.1 1.1 0.4 251 7 243 305 95 0 95 0 -6.1 0 -5.8 -6.2 01/05/2005 05:20:00 10.7 0.9 12.6 7.6 9.9 1.1 12.2 6.8 0.8 1 7.2 0.4 252 6 253 305 95 0 95 0 -6.2 0 -6 -6.4 01/05/2005 05:30:00 9.3 1.1 11.5 5.7 8.3 1.3 11.1 4.9 2.3 2.1 7.6 0.4 253 6 258 305 94 0 94 0 -6.2 0 -6 -6.4 01/05/2005 05:40:00 8.8 0.9 10.7 5.7 7.9 1.1 10.7 5.3 3 1.9 8 0.4 254 7 258 305 94 0 95 0 -6.3 0 -5.8 -6.4 01/05/2005 05:50:00 8.8 0.9 10.7 6.5 7.8 1.1 10.3 4.9 1.7 1.1 6.5 0.4 253 7 261 305 95 0 94 0 -6.2 0 -5.8 -6.4 01/05/2005 06:00:00 8.3 1.1 10.7 4.9 7.4 1.2 10.7 4.6 2 1.5 6.5 0.4 252 8 250 305 95 0 95 0 -6.2 0 -5.8 -6.4 01/05/2005 06:10:00 8.7 0.9 11.1 6.5 8.2 1.1 11.5 4.9 2.5 1.5 6.5 0.4 249 6 250 305 95 0 95 0 -6.2 0 -5.8 -6.4 01/05/2005 06:20:00 8.4 1 10.7 5.7 7.5 1.2 10.3 4.6 2.4 1.2 6.1 0.4 253 6 254 305 95 0 95 0 -6.1 0 -5.8 -6.2 01/05/2005 06:30:00 7.7 1 9.9 4.9 7.2 1.2 9.1 4.2 4 2.2 8 0.4 247 7 247 305 95 0 95 0 -6.2 0 -5.6 -6.2 01/05/2005 06:40:00 8.3 0.9 10.3 6.1 7.7 1 9.9 4.9 3.6 2.1 7.6 0.4 242 6 240 305 95 0 95 0 -6.2 0 -5.8 -6.4 01/05/2005 06:50:00 7.7 0.9 9.9 5.7 7.1 1.1 9.5 4.2 3.9 2.4 8.4 0.4 248 7 251 305 94 0 94 0 -6.2 0 -5.8 -6.2 01/05/2005 07:00:00 7.9 0.8 9.5 5.7 7.3 1 9.5 4.9 4.7 1.1 7.2 1.1 239 6 245 305 94 0 94 0 -6.2 0 -5.8 -6.2 01/05/2005 07:10:00 7.1 0.8 8.8 4.6 6.5 1 8.4 4.2 3.9 1.2 6.8 0.4 238 5 239 305 94 0 93 0 -6.2 0 -5.8 -6.2 01/05/2005 07:20:00 7.7 0.7 9.5 5.7 7.2 0.8 9.1 4.6 5.1 1.1 7.6 1.9 235 5 237 305 94 0 94 0 -6.1 0 -5.6 -6.2 01/05/2005 07:30:00 7.5 0.6 9.1 5.3 7.1 0.7 8.8 4.9 3.2 1.9 7.2 0.4 229 5 231 305 95 0 95 0 -6 0 -5.6 -6.2 01/05/2005 07:40:00 7.2 0.7 9.1 4.9 6.7 0.8 8.8 4.9 1.8 1.1 5.3 0.4 235 5 235 305 96 0 96 0 -5.9 0 -5.6 -6 01/05/2005 07:50:00 6.9 0.6 8 4.9 6.4 0.7 8 4.6 0.6 0.7 4.6 0.4 229 6 237 305 97 0 96 0 -5.8 0 -5.6 -6 01/05/2005 08:00:00 6.9 0.6 8.4 4.9 6.4 0.6 7.6 4.6 0.7 1 4.9 0.4 234 5 234 305 97 0 97 0 -5.7 0 -5.6 -5.8 01/05/2005 08:10:00 6.8 0.6 8 4.9 6.4 0.7 8 4.6 0.4 0 0.4 0.4 228 5 223 305 98 0 98 0 -5.6 0 -5.6 -5.8 01/05/2005 08:20:00 6.3 0.6 7.6 4.6 5.9 0.6 7.2 4.6 0.4 0 0.4 0.4 229 4 227 305 98 0 98 0 -5.5 0 -5.3 -5.6 01/05/2005 08:30:00 6.1 0.6 7.2 4.2 5.7 0.6 7.2 4.2 0.4 0 0.4 0.4 226 5 226 305 99 0 99 0 -5.5 0 -5.3 -5.6 01/05/2005 08:40:00 6.3 0.4 6.8 5.3 6 0.5 7.2 4.6 0.4 0 0.4 0.4 219 4 217 305 99 0 99 0 -5.4 0 -4.9 -5.6 01/05/2005 08:50:00 5.7 0.5 6.8 4.6 5.4 0.6 6.8 3.8 0.4 0 0.4 0.4 220 4 222 305 100 0 100 0 -5.3 0 -5.1 -5.6 01/05/2005 09:00:00 5.5 0.4 6.5 4.2 5.2 0.5 6.5 3.8 0.4 0 0.4 0.4 220 4 215 305 100 0 100 0 -5.3 0 -5.1 -5.6 01/05/2005 09:10:00 5.5 0.5 6.5 4.2 5.3 0.6 6.5 3.4 0.4 0 0.4 0.4 213 2 216 305 101 0 101 0 -5.2 0 -5.1 -5.6 01/05/2005 09:20:00 5.3 0.4 6.5 4.2 5 0.6 6.1 3.4 0.4 0 0.4 0.4 208 4 202 305 101 0 101 0 -5.2 0 -5.1 -5.3 01/05/2005 09:30:00 5.5 0.4 6.5 4.2 5.4 0.5 6.5 3.8 0.4 0 0.4 0.4 202 5 205 305 102 0 102 0 -5.1 0 -4.9 -5.1 01/05/2005 09:40:00 5.5 0.4 6.5 4.6 5.6 0.4 6.5 4.6 0.4 0 0.4 0.4 187 2 187 305 102 0 103 0 -5.1 0 -4.9 -5.3 01/05/2005 09:50:00 6.2 0.6 7.6 3.8 6.3 0.5 7.6 4.9 0.4 0 0.4 0.4 186 2 186 305 103 0 103 0 -5.1 0 -5.1 -5.3 01/05/2005 10:00:00 6.3 0.8 7.2 2.6 6.7 0.4 7.6 4.9 0.4 0 0.4 0.4 184 4 191 305 103 0 103 0 -5.1 0 -4.7 -5.3 01/05/2005 10:10:00 4.2 0.9 6.8 2.6 5.9 0.5 7.6 4.9 0.4 0 0.4 0.4 175 6 194 305 104 0 104 0 -5 0 -4.7 -5.1 01/05/2005 10:20:00 4.5 0.9 6.5 2.6 6.1 0.6 7.6 4.9 0.4 0 0.4 0.4 172 7 186 305 103 0 103 0 -5.1 0 -4.9 -5.6 01/05/2005 10:30:00 4.4 0.8 6.8 3 6.6 0.5 7.6 4.9 0.4 0 0.4 0.4 168 5 163 305 104 0 104 0 -5 0 -4.7 -5.1 01/05/2005 10:40:00 6.1 0.8 8 3.4 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 158 4 159 305 104 0 103 0 -5 0 -4.9 -5.1 01/05/2005 10:50:00 6.3 0.6 7.6 4.6 6.2 0.6 7.2 4.6 0.4 0 0.4 0.4 148 6 147 305 104 0 104 0 -5 0 -4.7 -5.1 01/05/2005 11:00:00 6.3 0.6 8 4.6 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 143 6 142 305 105 0 105 0 -4.8 0 -4.7 -4.9 01/05/2005 11:10:00 7.2 0.7 8.8 4.6 7.1 0.7 8.8 5.3 0.4 0 0.4 0.4 141 5 145 305 107 0 107 0 -4.6 0 -4.5 -4.7 01/05/2005 11:20:00 8.5 0.8 10.3 6.5 8.4 0.8 10.7 6.1 0.4 0 0.4 0.4 139 5 133 305 108 0 108 0 -4.4 0 -4.2 -4.7 01/05/2005 11:30:00 9.7 0.6 11.1 8 9.5 0.6 11.1 8 0.4 0 0.4 0.4 138 4 151 305 109 0 109 0 -4.2 0 -4 -4.5 01/05/2005 11:40:00 11.3 0.8 13.3 9.1 11 0.8 13.3 8.8 0.4 0 0.4 0.4 142 4 141 305 111 1 112 0 -4 0 -3.8 -4.2 01/05/2005 11:50:00 12.2 0.8 14.9 9.9 12 0.8 14.5 9.1 0.4 0 0.4 0.4 144 5 142 305 113 1 112 0 -3.9 0 -3.6 -4 01/05/2005 12:00:00 12.1 0.9 14.9 9.5 11.8 0.8 14.5 9.1 0.4 0 0.4 0.4 145 5 151 305 114 0 114 0 -3.7 0 -3.3 -3.8 01/05/2005 12:10:00 10.2 1.4 13.7 6.1 10.5 0.8 13 7.6 0.4 0 0.4 0.4 154 8 154 305 116 1 116 0 -3.3 0.2 -2.4 -3.6 01/05/2005 12:20:00 9 1.5 13 5.7 11.8 0.9 13.7 8.8 0.4 0 0.4 0.4 175 6 179 305 124 3 123 0 -1 0.8 0.3 -2.7 01/05/2005 12:30:00 10.9 1 13.7 7.6 11.4 1.3 14.5 8 0.4 0 0.4 0.4 188 7 181 305 128 1 129 0 -0.3 0 0.3 -0.4 01/05/2005 12:40:00 11.8 0.9 13.7 9.1 11.4 1 13.3 8.4 0.4 0 0.4 0.4 198 4 200 305 126 0 126 0 -0.2 0 0.1 -0.4 01/05/2005 12:50:00 12.8 0.6 14.5 11.5 12.3 0.8 14.5 9.5 0.4 0 0.4 0.4 198 3 200 305 124 1 124 0 -0.3 0 0.1 -0.4 01/05/2005 13:00:00 12.5 0.6 14.5 11.1 12.2 0.7 14.1 9.5 0.4 0 0.4 0.4 200 3 200 305 122 0 122 0 -0.3 0 -0.1 -0.4 01/05/2005 13:10:00 12.1 0.6 13.7 10.3 11.7 0.6 13.3 9.5 0.4 0 0.4 0.4 205 3 205 305 120 1 121 0 -0.3 0 0.1 -0.4 01/05/2005 13:20:00 11.6 0.6 13.7 10.3 11.1 0.7 13 8.4 0.4 0 0.4 0.4 207 3 203 305 118 0 118 0 -0.3 0 0.1 -0.4 01/05/2005 13:30:00 11.8 0.7 13.7 9.1 11.2 0.8 13.3 8.8 0.4 0 0.4 0.4 211 4 210 305 117 0 117 0 -0.3 0 0.1 -0.4 01/05/2005 13:40:00 12.3 0.8 14.5 9.9 11.5 0.9 14.1 8.8 0.4 0 0.4 0.4 210 4 206 305 117 0 117 0 -0.1 0 0.1 -0.4 01/05/2005 13:50:00 12.4 0.8 14.5 9.9 11.5 1 14.5 9.1 0.4 0 0.4 0.4 211 4 210 305 117 0 117 0 -0.1 0 0.1 -0.4 01/05/2005 14:00:00 13.3 0.9 15.3 9.9 12.4 1 14.9 9.1 0.4 0 0.4 0.4 213 4 212 305 117 0 116 0 0 0 0.3 -0.1 01/05/2005 14:10:00 13.7 1.1 16.1 9.9 12.6 1.4 16.1 8.8 0.4 0 0.4 0.4 213 4 210 305 115 0 115 0 0.1 0 0.3 0.1 01/05/2005 14:20:00 13.2 1 16.4 9.9 12.3 1.2 15.3 8.8 0.4 0 0.4 0.4 211 4 212 305 116 1 115 0 0.1 0 0.6 0.1 01/05/2005 14:30:00 12.6 1 15.6 10.3 11.9 1.1 14.9 8.8 0.4 0 0.4 0.4 212 4 214 305 120 2 118 0 0 0 0.6 0.1 01/05/2005 14:40:00 12.6 0.9 15.3 8.8 11.8 1.1 14.9 8.4 0.4 0 0.4 0.4 211 4 218 305 125 1 126 0 0.1 0.1 0.6 0.1 01/05/2005 14:50:00 12.9 0.8 14.9 10.7 12.3 1.1 14.9 9.5 0.8 1.2 9.9 0.4 214 5 211 305 126 1 125 0 0.1 0.1 0.6 0.1 01/05/2005 15:00:00 12.8 0.8 14.9 10.7 12.3 1 14.9 9.1 4.7 2.9 12.6 0.4 210 4 212 305 126 1 126 0 0.1 0.1 0.6 0.1 01/05/2005 15:10:00 13.5 0.9 16.1 11.5 13.1 1 15.3 9.9 7.6 3.6 15.3 0.4 209 4 208 305 126 0 125 0 0.2 0.1 0.6 0.1 01/05/2005 15:20:00 13.8 0.8 15.6 11.8 13.3 1 15.6 10.7 12.8 1.4 15.3 8 209 4 215 305 125 0 125 0 0.2 0.1 0.6 0.1 01/05/2005 15:30:00 13.4 0.9 15.6 10.7 12.7 1.1 15.6 9.5 12.7 1.1 15.3 9.1 211 4 210 305 122 1 121 0 0.1 0.1 0.6 0.1 01/05/2005 15:40:00 13.4 1 16.1 9.9 12.5 1.1 15.3 9.5 12.5 1.2 15.3 9.1 212 4 213 305 119 1 118 0 0.1 0.1 0.6 0.1 01/05/2005 15:50:00 13.3 0.8 15.6 10.3 12.5 1.1 15.6 9.9 11.3 2 15.6 5.7 213 4 203 305 120 3 126 0 0.2 0.1 0.6 0.1 01/05/2005 16:00:00 13.5 0.9 15.6 10.3 12.7 1.2 15.6 9.9 12.7 1.2 15.6 9.5 212 5 211 305 121 2 121 0 0.2 0.1 0.6 0.1 01/05/2005 16:10:00 13.9 1 16.4 11.1 13.2 1.2 16.1 9.5 13.2 1.2 16.1 9.5 210 4 211 305 117 0 117 0 0.2 0.1 0.6 0.1 01/05/2005 16:20:00 13.9 1 16.4 10.3 12.9 1.1 16.1 10.3 12.9 1.1 16.1 10.3 211 5 215 305 118 0 119 0 0.2 0.1 0.6 0.1 01/05/2005 16:30:00 14.2 1 16.4 11.1 13.3 1.2 16.1 8.8 13.3 1.2 16.1 8.8 211 4 205 305 118 2 119 0 0.2 0.1 0.6 0.1 01/05/2005 16:40:00 14.6 1 17.2 12.2 13.9 1.2 17.6 10.3 13.5 1.6 17.6 6.5 209 3 210 305 115 0 114 0 0.2 0.1 0.6 0.1 01/05/2005 16:50:00 14.3 1 17.2 11.8 13.6 1.1 16.4 9.9 10.8 2.4 16.4 0.7 209 4 215 305 115 0 115 0 0.2 0.1 0.6 0.1 01/05/2005 17:00:00 14 0.9 16.8 11.5 13.4 1 16.1 10.7 7.8 2.8 14.9 0.7 210 4 210 305 113 1 115 0 0.3 0 0.8 0.1 01/05/2005 17:10:00 13.8 0.8 15.6 11.8 13.2 1 16.4 11.1 4.8 2.9 14.1 0.4 207 4 208 305 113 0 113 0 0.2 0.1 0.6 0.1 01/05/2005 17:20:00 14 0.8 15.6 11.8 13.4 0.8 15.6 11.1 8.9 2.8 15.3 0.4 207 3 214 305 120 2 113 0 0 0.1 0.6 0.1 01/05/2005 17:30:00 13.9 0.9 16.1 11.5 13.4 1 15.6 10.3 10.8 2.1 15.6 1.9 210 3 216 305 121 0 121 0 0 0 0.6 0.1 01/05/2005 17:40:00 13.8 0.9 16.4 10.7 13.1 1 15.3 10.3 10.5 2.1 14.9 3 211 4 208 305 121 0 121 0 0 0 0.6 0.1 01/05/2005 17:50:00 14.3 1.1 17.9 11.5 13.6 1.2 17.9 10.7 11.8 2.3 17.9 3.8 211 4 210 305 121 0 121 0 0.1 0.1 0.6 0.1 01/05/2005 18:00:00 14.7 1.1 18.3 11.5 14.1 1.3 17.2 9.9 13.9 1.5 17.2 8 213 5 217 305 120 0 120 0 0.2 0.1 0.8 0.1 01/05/2005 18:10:00 14.5 1.1 17.9 11.5 14.1 1.3 18.3 10.3 14.1 1.3 18.3 10.3 216 4 221 305 120 0 120 0 0.3 0 0.8 0.1 01/05/2005 18:20:00 15 1.2 18.3 11.5 14.6 1.4 18.3 10.7 14.6 1.5 18.3 10.7 215 4 220 305 120 0 120 0 0.3 0 0.8 0.1 01/05/2005 18:30:00 15.2 1 18.7 11.5 14.7 1.2 19.1 10.3 14.3 1.7 19.1 8 215 4 214 305 120 0 120 0 0.3 0 0.8 0.1 01/05/2005 18:40:00 14.3 1 16.8 11.1 13.7 1.5 16.8 8.8 12.1 2.7 16.8 3.4 215 5 224 305 120 0 120 0 0.3 0.1 0.8 0.1 01/05/2005 18:50:00 13.7 0.8 15.6 11.5 13.1 0.9 15.3 10.3 10.6 2 15.3 1.9 209 4 207 305 120 0 120 0 0.1 0.1 0.6 0.1 01/05/2005 19:00:00 14.2 0.8 16.4 12.2 13.7 0.9 15.6 10.7 12.8 1.8 15.6 4.9 208 3 211 305 120 0 120 0 0.1 0.1 0.6 0.1 01/05/2005 19:10:00 14.9 0.9 17.6 12.6 14.4 1 16.8 11.5 14.3 1 17.2 10.7 207 3 208 305 120 0 120 0 0.1 0.1 0.6 0.1 01/05/2005 19:20:00 15.1 1 17.6 12.6 14.5 1 17.2 11.1 14.5 1.1 17.6 10.3 207 3 207 305 120 0 120 0 0.1 0.1 0.6 0.1 01/05/2005 19:30:00 15.2 1.1 18.7 12.6 14.3 1.2 17.9 11.5 14.3 1.3 17.9 10.7 209 3 209 305 120 0 120 0 0.1 0.1 0.6 0.1 01/05/2005 19:40:00 15.1 1 17.9 11.5 14 1.3 16.8 9.9 14 1.3 16.8 8.4 211 4 214 305 120 0 120 0 0 0.1 0.6 -0.1 01/05/2005 19:50:00 14.7 1.1 17.6 11.1 13.6 1.3 16.4 9.5 13.6 1.4 16.4 8.8 212 4 210 305 118 1 117 0 0 0.1 0.6 0.1 01/05/2005 20:00:00 15.4 1 18.7 12.2 14.7 1.1 17.9 11.5 14.7 1.1 17.6 11.5 210 4 208 305 118 0 117 0 0.1 0.1 0.6 0.1 01/05/2005 20:10:00 15.6 1 18.7 13 14.9 1.2 18.7 11.8 14.9 1.2 18.3 11.8 209 4 218 305 118 0 117 0 0.1 0.1 0.6 0.1 01/05/2005 20:20:00 15.9 1 18.7 13 15.1 1.2 18.3 11.5 15.1 1.2 18.3 11.8 209 4 212 305 118 0 118 0 0.1 0.1 0.6 0.1 01/05/2005 20:30:00 15.6 1.1 18.7 12.6 14.5 1.3 18.3 10.7 14.5 1.3 18.3 10.7 211 4 209 305 118 0 118 0 0.2 0 0.6 0.1 01/05/2005 20:40:00 15.6 1 18.3 11.8 14.7 1.2 16.8 11.5 14.7 1.2 17.2 11.5 211 4 213 305 118 1 117 0 0.3 0 0.6 0.1 01/05/2005 20:50:00 15.4 1.2 18.3 12.2 14.3 1.4 17.9 11.1 14.3 1.5 17.9 10.7 212 4 214 305 120 0 120 0 0.3 0 0.8 0.1 01/05/2005 21:00:00 15.4 1.2 18.7 12.6 14.3 1.5 19.1 9.9 14.3 1.5 19.1 9.5 213 5 215 305 119 0 119 0 0.2 0.1 0.8 0.1 01/05/2005 21:10:00 15.5 1 17.9 12.2 14.4 1.3 17.9 11.1 14.4 1.3 17.9 11.1 212 4 210 305 119 0 119 0 0.2 0.1 0.8 0.1 01/05/2005 21:20:00 15.9 1.2 18.7 12.6 14.6 1.5 17.9 10.3 14.6 1.5 17.9 10.3 213 5 218 305 119 0 119 0 0.2 0.1 0.8 0.1 01/05/2005 21:30:00 15.3 1.2 18.7 12.2 14.1 1.4 17.6 10.7 14.1 1.4 17.6 9.9 212 4 213 305 119 0 119 0 0.2 0.1 0.6 0.1 01/05/2005 21:40:00 15.4 1 17.2 11.1 14.4 1.3 16.8 9.9 14.4 1.3 16.8 8.8 210 4 214 305 118 0 118 0 0.1 0.1 0.6 0.1 01/05/2005 21:50:00 15 1.2 17.9 11.1 14 1.6 17.2 9.9 14 1.6 17.6 9.9 211 4 212 305 118 0 118 0 0.2 0.1 0.6 0.1 01/05/2005 22:00:00 14.5 1 17.2 11.8 13.5 1.2 16.1 9.9 13.5 1.2 16.1 8.8 210 4 212 305 118 0 118 0 0.1 0.1 0.6 0.1 01/05/2005 22:10:00 14.2 1 17.2 10.7 13.5 1.1 16.4 10.3 13.5 1.1 16.4 9.9 209 4 208 305 118 0 117 0 0.1 0.1 0.6 0.1 01/05/2005 22:20:00 13.9 1 16.8 11.5 13.2 1.1 16.4 10.3 13.2 1.1 16.4 9.9 210 4 209 305 117 0 117 0 0.1 0.1 0.6 0.1 01/05/2005 22:30:00 14.1 0.9 16.8 11.8 13.3 1 16.1 9.9 13.3 1 16.4 9.5 210 4 214 305 117 0 117 0 0.1 0.1 0.6 0.1 01/05/2005 22:40:00 14.1 0.9 16.4 11.5 13.3 1 16.8 10.3 13.3 1 16.8 9.9 210 4 206 305 117 0 117 0 0.2 0.1 0.6 0.1 01/05/2005 22:50:00 14.4 0.8 17.2 12.6 13.8 0.8 16.1 11.8 13.8 0.8 16.4 11.5 206 4 210 305 117 0 117 0 0.1 0.1 0.6 0.1 01/05/2005 23:00:00 14.6 0.8 16.8 12.6 14.1 0.8 16.8 11.5 14.1 0.8 16.8 11.5 205 3 198 305 117 0 117 0 0.1 0.1 0.6 0.1 01/05/2005 23:10:00 15 0.8 17.6 13.3 14.4 0.9 17.2 11.8 14.4 0.9 16.8 11.8 207 3 208 305 117 0 117 0 0 0.1 0.6 0.1 01/05/2005 23:20:00 15.2 0.8 17.2 12.2 14.4 0.9 16.4 11.5 14.4 0.9 16.4 11.5 208 3 214 305 117 0 117 0 0 0.1 0.6 -0.1 01/05/2005 23:30:00 15.4 1 17.9 11.5 14.5 1.2 17.2 11.1 14.5 1.2 17.2 10.7 209 4 202 305 116 0 117 0 0 0.1 0.6 0.1 01/05/2005 23:40:00 15.9 0.9 18.3 13.3 14.9 1.1 17.9 11.1 14.9 1.1 17.6 11.5 210 4 208 305 116 0 116 0 0.2 0.1 0.8 0.1 01/05/2005 23:50:00 15.6 0.9 17.9 11.8 14.9 1 17.2 11.8 14.9 1 17.2 11.8 208 4 209 305 116 0 116 0 0.2 0.1 0.8 0.1 01/06/2005 00:00:00 15.8 0.9 18.7 13.3 15.2 0.9 17.6 13 15.2 0.9 17.6 13 205 3 203 305 115 1 116 0 0.2 0.1 0.6 0.1 01/06/2005 00:10:00 16.1 0.8 18.3 14.1 15.4 0.9 17.9 12.2 15.4 0.9 17.9 12.2 207 3 210 305 115 0 115 0 0.2 0.1 0.6 0.1 01/06/2005 00:20:00 15.6 0.9 19.5 13.3 14.8 1 18.3 11.5 14.8 1 18.7 11.5 209 3 208 305 115 0 115 0 0.1 0.1 0.6 0.1 01/06/2005 00:30:00 15.3 1 19.1 11.8 14.4 1.1 17.6 10.7 14.4 1.1 17.6 10.7 210 4 203 305 115 0 115 0 0.1 0.1 0.6 0.1 01/06/2005 00:40:00 15.3 1 18.3 11.8 14.1 1.1 16.8 11.1 14.1 1.1 16.8 11.1 211 4 210 305 115 0 115 0 0.1 0.1 0.6 0.1 01/06/2005 00:50:00 15 1.1 17.9 11.1 13.7 1.3 16.8 9.9 13.7 1.3 17.2 9.9 212 4 210 305 115 0 115 0 0.1 0.1 0.6 0.1 01/06/2005 01:00:00 14.6 1.1 19.9 12.2 13.6 1.3 18.3 10.3 13.6 1.3 18.3 10.3 211 5 204 305 115 0 115 0 0.1 0.1 0.6 0.1 01/06/2005 01:10:00 15 1.3 17.9 9.9 13.9 1.5 18.3 9.9 13.9 1.5 18.3 9.9 214 5 221 305 115 0 115 0 0.2 0.1 0.6 0.1 01/06/2005 01:20:00 14.6 1.1 17.2 11.5 13.4 1.4 17.2 9.9 13.4 1.4 16.8 9.9 213 5 212 305 115 0 115 0 0.1 0.1 0.6 0.1 01/06/2005 01:30:00 15.1 1.2 17.9 11.1 14.2 1.6 17.2 9.5 14.2 1.6 17.2 9.5 214 4 208 305 115 0 115 0 0.1 0.1 0.6 0.1 01/06/2005 01:40:00 14.5 1.2 17.9 11.5 13.4 1.3 17.9 10.3 13.4 1.3 17.6 10.3 213 4 222 305 115 0 115 0 0 0.1 0.6 -0.1 01/06/2005 01:50:00 13.9 1.3 17.2 10.7 12.8 1.6 16.4 9.1 12.8 1.6 16.1 9.1 213 4 218 305 115 0 115 0 0 0.1 0.6 -0.4 01/06/2005 02:00:00 12.7 1 15.3 9.9 11.9 1.1 14.5 8.8 11.9 1.1 14.9 8.4 209 5 212 305 115 0 115 0 -0.1 0 0.6 -0.4 01/06/2005 02:10:00 12.9 0.8 14.9 11.1 12.4 0.9 15.3 9.5 12.4 0.9 15.3 9.5 207 4 202 305 115 0 115 0 0 0 0.3 -0.4 01/06/2005 02:20:00 13.1 1 15.6 9.5 12.6 1 15.3 9.9 12.6 1 15.3 9.5 207 4 205 305 115 0 115 0 0 0.1 0.6 -0.1 01/06/2005 02:30:00 13.9 1 16.4 10.7 12.9 1 15.6 9.9 12.9 1 15.6 9.9 211 5 218 305 115 0 115 0 0.2 0.1 0.8 0.1 01/06/2005 02:40:00 13.5 1.2 16.8 9.5 12.4 1.2 16.1 9.5 12.4 1.2 16.1 9.5 211 4 213 305 115 0 115 0 0 0 0.6 -0.1 01/06/2005 02:50:00 14.3 1.2 17.6 9.5 13.1 1.2 16.1 9.5 13.1 1.2 16.1 9.5 212 4 216 305 115 0 115 0 -0.1 0 0.3 -0.4 01/06/2005 03:00:00 15.6 0.8 17.9 13 14.4 1.1 16.8 11.5 14.4 1.1 16.4 11.5 210 4 205 305 115 0 115 0 -0.1 0 0.3 -0.4 01/06/2005 03:10:00 16.3 0.8 18.7 13 15.1 1 17.6 11.8 15.1 1 17.6 11.8 210 3 209 305 115 0 115 0 -0.1 0 0.3 -0.1 01/06/2005 03:20:00 16.9 1 19.5 13 15.9 1.1 18.7 12.2 15.9 1.1 18.7 12.2 209 3 212 305 115 1 115 0 -0.1 0 0.3 -0.4 01/06/2005 03:30:00 17.9 0.9 20.2 15.6 17 1 19.1 14.1 17 1 19.1 14.1 207 3 208 305 116 0 116 0 -0.2 0 0.3 -0.4 01/06/2005 03:40:00 18.4 0.8 20.6 15.6 17.5 1.1 20.2 13.3 17.5 1.1 19.9 13.3 208 3 213 305 116 0 117 0 -0.1 0 0.3 -0.4 01/06/2005 03:50:00 19.7 1.1 23.3 15.6 18.5 1.3 22.9 15.3 18.5 1.3 22.9 15.3 209 4 205 305 116 0 116 0 0.3 0.2 0.8 0.1 01/06/2005 04:00:00 19.9 1 22.1 17.2 19.1 1 21.8 16.1 19.1 1 21.8 16.1 206 3 211 305 115 0 114 0 0.2 0.1 0.6 0.1 01/06/2005 04:10:00 19 1.1 22.1 15.6 18.2 1.2 21.4 14.5 18.2 1.2 21.4 14.5 206 4 207 305 115 0 115 0 0 0.1 0.6 0.1 01/06/2005 04:20:00 18.9 1 21.4 16.8 18.1 1 21 15.3 18.1 1 21.4 15.3 206 3 205 305 115 0 115 0 0.2 0.1 0.8 0.1 01/06/2005 04:30:00 18.3 1 21 16.1 17.5 1 20.6 14.9 17.5 1.1 20.6 14.9 204 3 205 305 115 0 115 0 0 0 0.6 -0.1 01/06/2005 04:40:00 17.7 1 20.2 13.7 16.9 1.1 19.9 13 16.9 1.2 19.5 13 206 3 210 305 114 0 114 0 0 0 0.6 -0.1 01/06/2005 04:50:00 16.7 0.9 19.1 14.5 16 0.9 18.7 13.3 16 0.9 18.3 13.3 205 3 208 305 114 0 114 0 -0.2 0 0.3 -0.4 01/06/2005 05:00:00 17.2 1.1 20.6 14.9 16.5 1.1 19.5 12.6 16.5 1.1 19.9 12.6 205 3 204 305 114 1 114 0 -0.3 0 0.3 -0.4 01/06/2005 05:10:00 17.5 0.9 20.2 15.3 16.7 1 19.5 13 16.7 1 19.9 13 206 3 207 305 115 0 115 0 -0.3 0 0.1 -0.4 01/06/2005 05:20:00 17.6 1 20.2 15.3 16.9 1 19.9 14.1 16.9 1 19.9 14.1 204 3 213 305 115 0 115 0 -0.2 0 0.3 -0.4 01/06/2005 05:30:00 17.8 1.1 21 15.3 17 1.2 20.2 13.7 17 1.2 20.6 13.7 202 3 203 305 115 0 115 0 -0.1 0 0.6 -0.4 01/06/2005 05:40:00 17.4 1 21.4 15.3 16.6 1.1 20.6 14.1 16.6 1.1 20.6 14.1 201 4 197 305 114 0 113 0 -0.2 0 0.1 -0.4 01/06/2005 05:50:00 17.3 0.9 19.5 15.3 16.6 0.9 19.5 14.1 16.6 0.9 19.5 14.1 204 3 208 305 113 0 113 0 -0.4 0 0.1 -0.4 01/06/2005 06:00:00 17.2 0.8 19.1 14.9 16.4 0.9 18.7 13.7 16.4 0.9 18.7 13.7 204 3 208 305 113 0 113 0 -0.4 0.1 0.1 -0.6 01/06/2005 06:10:00 16.9 0.9 19.5 14.9 16.1 1 18.7 13.3 16.1 1 18.7 13.3 204 3 200 305 113 0 113 0 -0.5 0 0.1 -0.6 01/06/2005 06:20:00 17 0.9 19.9 14.9 16.4 0.9 19.1 14.1 16.4 0.9 19.1 14.1 204 3 198 305 112 0 112 0 -0.7 0 0.1 -1.1 01/06/2005 06:30:00 17.5 1 20.2 15.3 16.8 1 19.5 13.7 16.8 1 19.5 13.3 202 3 203 305 110 0 111 0 -1 0.1 -0.4 -1.1 01/06/2005 06:40:00 17.9 1.3 21.4 13 17 1.4 21 12.6 17 1.4 21 12.6 207 4 215 305 110 0 110 0 -1.2 0 -0.6 -1.3 01/06/2005 06:50:00 17.6 1.3 20.6 14.5 16.9 1.4 20.6 13 16.9 1.4 20.6 12.6 206 4 206 305 111 1 112 0 -1.3 0 -0.8 -1.5 01/06/2005 07:00:00 17.1 1 19.9 14.5 16.4 1.2 18.7 12.2 16.4 1.2 18.7 12.2 206 4 206 305 112 0 112 0 -1.4 0 -1.1 -1.5 01/06/2005 07:10:00 16.7 1.1 19.9 13 15.9 1.3 18.7 11.8 15.9 1.3 18.7 11.8 209 4 208 305 112 0 112 0 -1.4 0 -1.1 -1.5 01/06/2005 07:20:00 16.9 1 19.5 13.3 16.3 1.1 19.1 12.6 16.3 1.1 19.1 12.6 208 4 213 305 112 0 112 0 -1.4 0 -1.1 -1.5 01/06/2005 07:30:00 16.8 1.2 20.2 13.7 16 1.5 19.9 11.5 16 1.5 19.9 11.5 207 4 208 305 109 1 109 0 -1.5 0 -1.1 -1.8 01/06/2005 07:40:00 16.3 1.3 19.1 12.6 15.8 1.3 18.7 11.8 15.8 1.3 19.1 11.8 203 3 203 305 108 1 108 0 -1.6 0 -1.1 -1.8 01/06/2005 07:50:00 15.2 1.1 17.6 11.8 14.6 1.2 17.6 11.1 14.6 1.2 17.6 11.1 199 4 199 305 107 1 107 0 -1.6 0 -1.1 -1.8 01/06/2005 08:00:00 15.9 0.9 18.3 13.7 15.5 1 18.3 12.6 15.5 1 18.3 12.6 202 4 200 305 105 1 106 0 -1.8 0 -1.3 -2 01/06/2005 08:10:00 15.7 1.1 17.9 12.2 15.2 1.1 17.6 11.5 15.2 1.1 17.6 11.8 202 3 203 305 103 0 103 0 -1.8 0 -1.3 -2 01/06/2005 08:20:00 15.5 0.9 17.9 13.3 15 1 17.6 11.8 15 1 17.6 11.8 203 3 205 305 102 0 102 0 -1.9 0 -1.3 -2 01/06/2005 08:30:00 15.2 1 17.9 12.6 14.7 1 17.6 12.2 14.7 1 17.6 12.2 203 3 199 305 102 0 103 0 -2 0 -1.8 -2.2 01/06/2005 08:40:00 15.2 1 17.6 12.6 14.6 1 16.8 11.8 14.6 1 16.8 11.8 202 3 198 305 102 0 102 0 -2.1 0 -1.5 -2.2 01/06/2005 08:50:00 14.8 0.9 17.6 12.6 14.4 1 17.2 11.5 14.4 1 17.2 11.5 203 3 202 305 104 0 103 0 -2 0 -1.8 -2 01/06/2005 09:00:00 16.4 1.2 19.5 13.7 15.8 1.2 18.7 13 15.8 1.2 18.7 13 203 3 203 305 106 1 105 0 -1.9 0 -1.5 -2 01/06/2005 09:10:00 16.3 1.2 19.5 13.7 15.6 1.2 18.7 12.2 15.6 1.2 18.7 12.2 205 4 201 305 107 0 107 0 -1.9 0 -1.8 -2 01/06/2005 09:20:00 16.9 1.5 21 13.3 16.1 1.5 21 12.2 16.1 1.5 21 12.2 205 5 211 305 108 1 107 0 -1.9 0 -1.8 -2 01/06/2005 09:30:00 17 1.3 19.9 13.7 16.5 1.2 19.1 12.6 16.5 1.2 19.1 12.6 203 3 206 305 108 0 108 0 -1.8 0 -1.3 -2 01/06/2005 09:40:00 16.5 1.4 20.2 13 16 1.4 19.9 13 16 1.4 19.9 13 201 4 198 305 108 0 108 0 -1.8 0 -1.3 -2 01/06/2005 09:50:00 16.2 1 18.7 13.3 15.6 1.2 18.3 12.2 15.6 1.2 18.3 12.2 198 3 195 305 108 0 108 0 -1.8 0 -1.3 -2 01/06/2005 10:00:00 14.9 1.2 17.9 11.8 14.3 1.3 17.6 10.7 14.3 1.3 17.6 10.7 198 4 198 305 108 0 108 0 -1.8 0 -1.3 -2 01/06/2005 10:10:00 14.2 1.1 16.8 11.1 13.8 1.1 16.1 10.3 13.8 1.1 16.1 10.3 200 4 202 305 108 0 107 0 -1.8 0 -1.3 -2 01/06/2005 10:20:00 14.9 0.8 17.2 12.6 14.4 1 17.2 11.5 14.4 1 16.8 11.5 198 3 199 305 108 0 108 0 -1.8 0 -1.3 -2 01/06/2005 10:30:00 15.1 1.1 17.9 12.2 14.5 1.2 17.9 11.5 14.5 1.2 17.9 11.5 199 4 201 305 108 0 108 0 -1.8 0 -1.3 -2 01/06/2005 10:40:00 15.6 1.1 18.7 13 15.2 1.2 17.9 12.2 15.2 1.2 17.9 12.2 199 3 201 305 109 0 109 0 -1.7 0 -1.3 -2 01/06/2005 10:50:00 14.3 1.5 17.6 11.1 13.8 1.6 17.6 9.5 13.8 1.6 17.6 8.8 198 4 199 305 109 0 109 0 -1.8 0 -1.1 -2 01/06/2005 11:00:00 14.1 1.4 17.9 11.5 13.6 1.6 17.9 9.5 13.6 1.6 17.9 9.5 197 4 195 305 109 0 109 0 -1.8 0 -1.3 -2 01/06/2005 11:10:00 13.1 1.3 16.8 10.3 12.7 1.3 17.2 9.1 12.6 1.4 16.8 8.4 194 4 196 305 109 0 109 0 -1.7 0 -1.1 -1.8 01/06/2005 11:20:00 14.8 1.2 17.9 11.1 14.3 1.2 17.2 10.3 14.3 1.3 17.2 10.3 194 4 198 305 110 0 109 0 -1.7 0 -1.1 -1.8 01/06/2005 11:30:00 14.6 1.3 17.6 10.3 14 1.4 17.2 10.3 14 1.4 17.2 10.3 194 4 202 305 110 0 110 0 -1.6 0 -1.1 -1.8 01/06/2005 11:40:00 14.4 1 16.4 11.1 14.1 1.1 16.4 10.7 14.1 1.1 16.4 10.7 191 3 194 305 109 1 110 0 -1.7 0 -1.1 -2 01/06/2005 11:50:00 12.3 2 16.4 6.8 12.8 1.2 16.4 9.9 12.8 1.2 16.4 9.9 185 7 184 305 108 1 108 0 -1.8 0 -1.3 -2 01/06/2005 12:00:00 8 1.3 11.5 4.9 10.8 1.4 14.5 8.4 10.7 1.5 14.5 7.2 165 6 162 305 105 1 106 0 -1.9 0 -1.5 -2 01/06/2005 12:10:00 7 1.6 13 4.2 9.5 1 12.6 7.6 9 1.5 12.6 4.9 167 7 152 305 104 1 103 0 -1.7 0.1 -1.3 -2 01/06/2005 12:20:00 7.6 1.7 12.6 4.2 10.3 1.3 13.7 7.2 9.9 1.7 13.7 4.6 175 6 184 305 105 1 105 0 -1.4 0 -1.1 -1.8 01/06/2005 12:30:00 6.4 1.2 9.9 4.2 8.7 0.8 11.5 7.2 7 1.7 11.5 2.3 173 7 193 305 104 1 104 0 -1.3 0 -0.8 -1.5 01/06/2005 12:40:00 9.5 2.2 14.1 4.9 11.2 1.3 14.9 7.6 10.5 2 14.9 4.6 179 8 183 305 106 1 106 0 -0.8 0.2 -0.4 -1.1 01/06/2005 12:50:00 11.1 1.5 14.1 6.5 12.8 1.2 16.1 9.9 12.7 1.3 16.1 9.1 182 6 190 305 109 1 110 0 -0.3 0.1 0.6 -0.6 01/06/2005 13:00:00 9.1 1.5 12.6 5.7 10.8 1.3 13.3 8 9.5 2.6 13.3 2.3 181 7 190 305 108 0 109 0 -0.8 0 -0.4 -1.1 01/06/2005 13:10:00 7 1.3 11.1 4.2 9.3 1 11.8 6.5 5.5 2.1 11.5 0.4 170 8 186 305 109 0 109 0 -0.8 0 -0.4 -1.1 01/06/2005 13:20:00 7.8 1.4 11.8 3.4 8.1 1 11.5 6.1 1.7 1.9 8.4 0.4 155 8 155 305 106 1 106 0 -1.2 0 -0.6 -1.5 01/06/2005 13:30:00 9.6 1.2 13 6.1 9.5 1.3 12.6 6.1 0.8 1.1 6.5 0.4 144 9 145 305 105 1 106 0 -1.4 0.2 -1.1 -1.8 01/06/2005 13:40:00 9.7 1.4 13 5.3 9.6 1.3 13.7 4.2 0.5 0.4 3.8 0.4 148 9 134 305 109 1 107 0 -1.2 0.1 -0.8 -1.5 01/06/2005 13:50:00 7.7 1.3 14.1 3.4 7.8 1.3 13 4.6 1.2 1.5 8.4 0.4 152 15 205 305 112 0 113 0 -0.6 0 0.1 -1.1 01/06/2005 14:00:00 7.5 1.2 10.3 3.8 8.2 1.1 11.5 6.1 2.9 2 9.5 0.4 160 12 177 305 112 0 112 0 -0.7 0 0.1 -0.8 01/06/2005 14:10:00 9.4 1.7 13.7 5.3 10.9 1.2 13.7 8 8.3 2.9 13.7 0.7 180 6 188 305 113 0 113 0 -0.5 0 0.1 -0.6 01/06/2005 14:20:00 8.5 1.1 11.5 5.7 11.2 1.1 14.1 8.4 9 2.5 14.1 1.5 175 6 183 305 112 0 112 0 -0.6 0.2 -0.1 -1.1 01/06/2005 14:30:00 8 1.3 13 5.3 11.5 0.9 14.1 9.1 10.5 1.6 14.1 4.2 169 6 186 305 111 1 112 0 -0.3 0.1 0.3 -0.6 01/06/2005 14:40:00 7.6 1.1 10.7 4.9 10.7 0.8 13.7 8.8 8.7 1.9 13.7 4.6 168 6 161 305 108 0 108 0 -0.4 0.1 0.1 -0.6 01/06/2005 14:50:00 8.7 1.3 12.2 5.3 12 1.2 14.5 8.8 11.1 1.9 14.5 4.6 173 7 171 305 111 1 112 0 0.2 0.2 0.6 -0.4 01/06/2005 15:00:00 8.5 1.2 11.8 6.1 12.1 1 14.5 9.1 9.2 2.7 14.1 2.6 171 5 165 305 115 0 115 0 0.2 0.1 0.8 0.1 01/06/2005 15:10:00 9.8 1.6 14.5 6.5 11.9 1 14.9 9.5 10.5 1.8 14.9 3.4 163 6 152 305 113 2 114 0 -0.2 0.1 0.3 -0.4 01/06/2005 15:20:00 13.2 1.6 16.4 8.8 12.8 1.5 15.6 9.1 4.6 4.3 14.9 0.4 145 7 141 305 108 2 106 0 -0.5 0.3 0.1 -1.1 01/06/2005 15:30:00 13.7 1.1 16.1 10.3 13.4 1 15.6 10.3 0.4 0 0.4 0.4 144 5 151 305 106 0 105 0 -1.1 0 -1.1 -1.3 01/06/2005 15:40:00 13.8 1 16.4 10.7 13.6 1 16.4 10.3 0.4 0 0.4 0.4 144 5 140 305 107 1 107 0 -1.1 0 -1.1 -1.3 01/06/2005 15:50:00 13.7 1.1 16.4 10.3 13.4 1.1 16.1 10.7 0.4 0 0.4 0.4 146 5 148 305 106 1 107 0 -1.1 0 -1.1 -1.3 01/06/2005 16:00:00 13.7 0.9 16.1 11.5 13.3 0.9 15.6 9.9 0.4 0 0.4 0.4 144 5 141 305 103 1 104 0 -1.2 0 -1.1 -1.3 01/06/2005 16:10:00 13.1 0.8 16.1 10.7 12.8 0.9 15.3 10.3 0.4 0 0.4 0.4 142 5 143 305 102 0 103 0 -1.2 0 -1.1 -1.3 01/06/2005 16:20:00 13.5 1.1 16.4 10.3 13.1 1.1 16.4 9.5 0.4 0 0.4 0.4 143 5 147 305 101 0 101 0 -1.3 0 -1.1 -1.3 01/06/2005 16:30:00 13.1 1.1 16.4 10.3 12.8 1 15.6 10.3 0.4 0 0.4 0.4 144 6 147 305 99 0 99 0 -1.4 0 -1.3 -1.5 01/06/2005 16:40:00 12.2 1.1 15.3 9.9 12 1 14.5 9.1 0.4 0 0.4 0.4 143 6 147 305 98 0 99 0 -1.5 0 -1.1 -1.8 01/06/2005 16:50:00 13.9 0.8 15.6 11.5 13.6 0.8 15.6 11.1 0.4 0 0.4 0.4 139 4 147 305 97 0 97 0 -1.5 0 -1.1 -1.8 01/06/2005 17:00:00 13.7 1.1 16.8 10.3 13.3 1.1 16.1 10.7 0.4 0 0.4 0.4 139 5 155 305 97 0 97 0 -1.6 0 -1.3 -1.8 01/06/2005 17:10:00 12 1.1 14.5 8.4 11.7 1.1 14.5 8.8 0.4 0 0.4 0.4 145 6 139 305 96 1 96 0 -1.7 0 -1.5 -1.8 01/06/2005 17:20:00 11.8 1.5 15.6 8.4 11.4 1.2 15.3 8.4 0.4 0 0.4 0.4 150 7 152 305 96 1 97 0 -1.5 0.1 -1.3 -1.8 01/06/2005 17:30:00 12.9 1.3 16.1 9.5 12.2 1.3 15.3 9.1 0.4 0 0.4 0.4 150 6 152 305 98 2 98 0 -1.4 0.2 -1.1 -1.8 01/06/2005 17:40:00 13.3 1.1 16.1 10.3 12.5 1.1 16.1 9.5 0.4 0 0.4 0.4 151 5 153 305 103 1 102 0 -1.1 0 -1.1 -1.3 01/06/2005 17:50:00 11.4 1.5 15.3 6.1 11.8 0.9 14.1 9.5 0.4 0 0.4 0.4 157 5 158 305 102 1 103 0 -1.3 0 -1.1 -1.5 01/06/2005 18:00:00 11.4 1.5 15.3 5.7 11.4 0.9 14.5 8.4 0.4 0 0.4 0.4 156 5 151 305 100 1 100 0 -1.5 0 -1.3 -1.8 01/06/2005 18:10:00 10.3 1 13.3 6.5 10.2 0.8 13 8 0.4 0 0.4 0.4 154 5 154 305 97 1 96 0 -1.7 0 -1.5 -1.8 01/06/2005 18:20:00 9.9 0.9 12.2 6.8 9.6 0.8 11.8 8 0.4 0 0.4 0.4 152 6 151 305 96 0 96 0 -1.7 0 -1.5 -1.8 01/06/2005 18:30:00 10.5 1 12.6 6.8 10.4 0.8 12.2 7.6 0.4 0 0.4 0.4 154 6 146 305 97 0 96 0 -1.7 0 -1.3 -1.8 01/06/2005 18:40:00 9.2 1.7 12.6 4.6 9.9 0.8 11.8 7.6 0.4 0 0.4 0.4 158 6 162 305 98 0 98 0 -1.7 0 -1.5 -1.8 01/06/2005 18:50:00 10.6 1 13 7.2 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 154 5 152 305 99 0 99 0 -1.7 0 -1.5 -1.8 01/06/2005 19:00:00 11.2 1 13.7 8 11 0.8 13.3 9.1 0.4 0 0.4 0.4 153 5 155 305 100 0 100 0 -1.6 0 -1.5 -1.8 01/06/2005 19:10:00 12.1 1.2 15.6 8.8 11.8 1.1 14.9 8.8 0.4 0 0.4 0.4 148 5 155 305 99 0 99 0 -1.7 0 -1.5 -1.8 01/06/2005 19:20:00 12.5 1.1 14.5 9.1 12.2 0.9 14.1 8.8 0.4 0 0.4 0.4 153 5 155 305 99 0 99 0 -1.7 0 -1.8 -1.8 01/06/2005 19:30:00 12.2 1.5 14.9 6.5 12.1 0.9 14.9 9.5 0.4 0 0.4 0.4 155 5 158 305 100 1 101 0 -1.7 0 -1.5 -1.8 01/06/2005 19:40:00 12 1.6 15.3 6.8 12.3 0.9 14.5 9.5 0.4 0 0.4 0.4 157 4 155 305 100 0 100 0 -1.7 0 -1.5 -2 01/06/2005 19:50:00 10.7 2 14.9 6.5 12.2 0.9 14.5 9.5 0.4 0 0.4 0.4 160 5 156 305 100 0 100 0 -1.7 0 -1.3 -2 01/06/2005 20:00:00 13 1.4 15.3 7.6 13 0.8 15.6 11.1 0.4 0 0.4 0.4 156 4 155 305 100 0 100 0 -1.7 0 -1.1 -2 01/06/2005 20:10:00 12.2 1.5 15.6 6.8 12.4 0.8 15.3 10.3 0.4 0 0.4 0.4 157 6 153 305 101 0 101 0 -1.7 0 -1.5 -2 01/06/2005 20:20:00 11.4 1.7 14.5 5.3 12 0.8 14.9 9.5 0.4 0 0.4 0.4 158 5 160 305 101 1 101 0 -1.7 0 -1.8 -1.8 01/06/2005 20:30:00 9.6 1.9 14.5 5.7 12 1.1 15.6 8.4 0.4 0 0.4 0.4 164 6 156 305 102 1 103 0 -1.5 0 -1.3 -1.8 01/06/2005 20:40:00 8.5 1.5 13 5.7 11.9 1 14.5 8.8 0.4 0 0.4 0.4 167 6 155 305 103 0 103 0 -1.3 0 -1.1 -1.5 01/06/2005 20:50:00 8.4 1.5 14.9 5.7 12.6 1.1 15.3 9.5 0.4 0 0.4 0.4 168 5 162 305 104 1 103 0 -1.2 0 -0.8 -1.3 01/06/2005 21:00:00 9 1.8 13 5.3 11.7 0.8 14.5 9.5 0.4 0 0.4 0.4 164 6 162 305 104 0 104 0 -1.2 0 -1.1 -1.3 01/06/2005 21:10:00 10.1 1.6 13.7 5.7 11.7 0.9 15.6 9.5 0.4 0 0.4 0.4 161 5 159 305 103 0 103 0 -1.1 0 -1.1 -1.3 01/06/2005 21:20:00 9.1 1.6 15.6 6.1 12.6 1 15.6 10.3 0.4 0 0.4 0.4 165 5 158 305 105 1 103 0 -1 0 -0.6 -1.1 01/06/2005 21:30:00 8.9 1.3 13.3 6.1 13.3 0.9 16.1 11.5 0.4 0 0.4 0.4 167 5 161 305 107 1 108 0 -0.5 0.1 -0.1 -0.8 01/06/2005 21:40:00 9.6 1.7 14.1 6.1 12.8 1 15.6 9.9 0.4 0 0.4 0.4 164 6 160 305 108 0 107 0 -0.5 0 0.1 -0.6 01/06/2005 21:50:00 10.4 1.7 14.9 6.5 12.8 1 16.4 10.3 0.4 0 0.4 0.4 162 6 168 305 109 1 109 0 -0.3 0 0.1 -0.6 01/06/2005 22:00:00 10.9 1.7 14.9 6.5 13.7 1.3 17.9 10.7 0.4 0 0.4 0.4 163 6 162 305 116 2 112 0 0 0 0.3 -0.1 01/06/2005 22:10:00 13.9 1.7 17.9 8.4 14.1 1.3 17.9 11.1 0.4 0 0.4 0.4 153 7 155 305 119 1 119 0 0.1 0.1 0.6 0.1 01/06/2005 22:20:00 11.1 2.2 16.1 5.7 12.8 1.1 16.8 9.9 0.4 0 0.4 0.4 159 8 149 305 120 0 119 0 0 0 0.3 -0.1 01/06/2005 22:30:00 9.3 1.6 13.3 5.3 12.6 1.2 16.1 9.5 0.4 0 0.4 0.4 168 8 159 305 120 0 120 0 0.2 0.2 0.6 -0.1 01/06/2005 22:40:00 11.2 1.8 14.9 5.7 13.2 1 16.4 10.3 0.4 0 0.4 0.4 180 5 180 305 123 1 123 0 0.6 0 1 0.6 01/06/2005 22:50:00 12.4 1 16.1 9.5 12.9 0.7 15.3 11.1 0.4 0 0.4 0.4 184 4 189 305 123 0 123 0 0.5 0 0.8 0.3 01/06/2005 23:00:00 13.2 0.8 15.3 11.1 13.1 0.9 15.3 9.9 0.4 0 0.4 0.4 189 4 182 305 122 0 122 0 0.4 0 0.8 0.3 01/06/2005 23:10:00 13.2 0.8 15.3 11.1 12.9 0.8 14.5 9.9 2.3 4.3 13.7 0.4 190 3 188 305 119 1 119 0 0.3 0 0.6 0.1 01/06/2005 23:20:00 12.9 0.8 14.9 10.7 12.6 0.9 14.5 9.5 0.4 0 0.4 0.4 190 3 189 305 119 0 119 0 0.2 0 0.6 0.1 01/06/2005 23:30:00 12.2 0.8 14.9 9.9 12 0.8 14.5 9.5 0.4 0 0.4 0.4 189 3 181 305 119 0 119 0 0.1 0 0.6 0.1 01/06/2005 23:40:00 11.2 1 13.7 8.4 11.2 1 13.7 9.1 0.4 0 0.4 0.4 187 3 191 305 119 0 119 0 0.1 0 0.3 0.1 01/06/2005 23:50:00 10.1 0.7 12.2 8 10 0.7 11.8 8 0.4 0 0.4 0.4 187 4 192 305 119 0 119 0 0.2 0 0.3 0.1 01/07/2005 00:00:00 10.6 0.8 12.6 8.8 10.6 0.8 12.2 8.8 0.4 0 0.4 0.4 187 3 191 305 119 1 120 0 0.3 0 1 0.1 01/07/2005 00:10:00 11 0.8 13 8.8 11.4 0.8 13.3 9.5 0.4 0 0.4 0.4 185 3 184 305 120 0 120 0 0.5 0 1 0.3 01/07/2005 00:20:00 10.9 1 13 7.6 11.6 0.7 13.3 9.5 0.4 0 0.4 0.4 184 3 192 305 120 0 120 0 0.6 0 1 0.6 01/07/2005 00:30:00 11.3 0.9 13.3 8.4 11.9 0.9 14.1 9.1 0.9 2.2 13.3 0.4 184 3 186 305 117 1 115 0 0.7 0.1 1.3 0.6 01/07/2005 00:40:00 11.8 0.6 13.3 9.9 11.9 0.7 13.7 9.1 0.4 0.1 1.5 0.4 187 3 189 305 112 2 112 0 0.7 0.1 1.3 0.6 01/07/2005 00:50:00 12.9 0.6 14.5 11.1 12.4 0.8 14.5 9.5 0.4 0 0.4 0.4 191 3 194 305 111 0 111 0 0.6 0.1 1.3 0.6 01/07/2005 01:00:00 12.6 0.5 14.1 11.1 12.2 0.8 14.1 9.5 0.4 0 0.4 0.4 192 3 198 305 111 0 111 0 0.6 0.1 1 0.6 01/07/2005 01:10:00 12.3 0.6 14.5 10.7 11.8 0.8 13.7 9.1 0.4 0 0.4 0.4 191 3 190 305 111 0 111 0 0.5 0 1 0.6 01/07/2005 01:20:00 12.3 0.6 14.1 9.5 11.8 0.8 13.7 9.5 0.4 0 0.4 0.4 192 3 196 305 111 0 111 0 0.5 0 1 0.3 01/07/2005 01:30:00 12.9 0.6 14.5 11.5 12.3 0.8 14.1 9.5 0.4 0 0.4 0.4 194 3 193 305 111 0 112 0 0.5 0 1 0.3 01/07/2005 01:40:00 13 0.7 14.9 10.3 12.5 0.8 14.5 9.5 0.4 0 0.4 0.4 194 3 197 305 112 0 112 0 0.6 0 1 0.6 01/07/2005 01:50:00 12.6 0.7 14.1 10.7 12.1 0.8 14.1 8.4 0.4 0 0.4 0.4 194 3 195 305 111 0 111 0 0.6 0.1 1 0.3 01/07/2005 02:00:00 11.8 0.5 13 10.3 11.2 0.8 13.3 8.4 0.4 0 0.4 0.4 193 3 192 305 111 0 111 0 0.5 0 1 0.6 01/07/2005 02:10:00 11.6 0.6 13 9.9 11 0.8 12.6 8.8 0.4 0 0.4 0.4 192 3 193 305 112 0 112 0 0.6 0.1 1 0.3 01/07/2005 02:20:00 11.7 0.6 13.3 9.9 11.2 0.7 13 8.8 0.4 0 0.4 0.4 193 3 193 305 112 0 112 0 0.6 0.1 1.3 0.6 01/07/2005 02:30:00 11.7 0.5 13.3 10.3 11.2 0.7 13 8.8 0.4 0 0.4 0.4 192 3 192 305 113 0 113 0 0.6 0.1 1 0.6 01/07/2005 02:40:00 11.7 0.6 13 9.9 11.2 0.7 13 9.1 0.4 0 0.4 0.4 193 3 197 305 113 0 113 0 0.6 0.1 1.3 0.6 01/07/2005 02:50:00 11.5 0.5 13 9.9 11 0.7 13 9.1 0.4 0 0.4 0.4 193 3 193 305 113 0 114 0 0.6 0.1 1.3 0.6 01/07/2005 03:00:00 11.6 0.6 13.3 9.9 11 0.7 13 8.8 0.4 0 0.4 0.4 195 3 196 305 114 0 114 0 0.5 0 1 0.6 01/07/2005 03:10:00 11.6 0.5 13 9.1 11.1 0.7 12.6 8.4 0.4 0 0.4 0.4 196 3 196 305 115 0 115 0 0.5 0 1 0.6 01/07/2005 03:20:00 11.8 0.5 13.3 9.5 11.2 0.7 13 8.8 0.4 0 0.4 0.4 195 3 195 305 115 0 115 0 0.5 0 1 0.6 01/07/2005 03:30:00 11.4 0.5 13 9.9 10.8 0.6 12.6 8.8 0.4 0 0.4 0.4 196 3 193 305 115 0 115 0 0.5 0 1 0.3 01/07/2005 03:40:00 11.3 0.6 12.6 9.5 10.7 0.7 12.6 8 0.4 0 0.4 0.4 197 3 200 305 115 0 114 0 0.5 0 1 0.3 01/07/2005 03:50:00 11.2 0.5 12.2 9.5 10.7 0.6 12.2 8.4 0.4 0 0.4 0.4 197 3 194 305 115 0 115 0 0.4 0 1 0.3 01/07/2005 04:00:00 11.4 0.6 13 9.9 11 0.7 13.3 8.8 0.4 0 0.4 0.4 196 3 201 305 114 0 114 0 0.4 0 1 0.3 01/07/2005 04:10:00 12 0.5 13.7 10.7 11.4 0.7 13.3 9.5 0.4 0 0.4 0.4 196 3 197 305 115 0 115 0 0.5 0 1 0.3 01/07/2005 04:20:00 12.2 0.5 13.7 10.7 11.6 0.6 13.3 9.5 0.4 0.5 8.8 0.4 195 3 196 305 116 1 117 0 0.5 0 1 0.3 01/07/2005 04:30:00 12.2 0.6 14.1 10.3 11.6 0.8 13.3 8.8 0.4 0 0.4 0.4 195 3 194 305 116 0 117 0 0.5 0 1 0.3 01/07/2005 04:40:00 12.5 0.6 14.1 10.7 11.9 0.8 13.7 9.5 0.4 0 0.4 0.4 195 3 192 305 116 0 117 0 0.5 0 1 0.3 01/07/2005 04:50:00 12.4 0.6 13.7 10.3 11.8 0.8 13.3 9.5 0.4 0 0.4 0.4 195 4 197 305 117 0 117 0 0.5 0 1 0.3 01/07/2005 05:00:00 12.7 0.6 14.5 9.9 12.1 0.8 14.5 9.5 0.4 0 0.4 0.4 194 3 194 305 117 0 117 0 0.5 0 0.8 0.3 01/07/2005 05:10:00 12.6 0.7 14.1 10.3 12.1 0.8 13.7 9.5 0.4 0 0.4 0.4 195 3 193 305 117 0 117 0 0.5 0 1 0.3 01/07/2005 05:20:00 12.4 0.5 13.3 10.7 11.8 0.8 13.3 9.1 0.4 0 0.4 0.4 195 3 197 305 117 0 116 0 0.5 0 0.6 0.3 01/07/2005 05:30:00 12 0.6 13.3 9.9 11.6 0.7 13 9.5 0.4 0 0.4 0.4 194 3 196 305 117 0 117 0 0.4 0 0.6 0.3 01/07/2005 05:40:00 12.2 0.5 13.3 10.7 11.6 0.7 13.3 9.5 0.4 0 0.4 0.4 194 3 198 305 117 0 117 0 0.5 0 1 0.3 01/07/2005 05:50:00 11.9 0.7 14.1 9.9 11.3 1 13.7 8.4 0.4 0 0.4 0.4 194 3 195 305 118 0 118 0 0.5 0 1 0.3 01/07/2005 06:00:00 11.8 0.7 13.3 9.9 11.2 0.8 13 9.1 0.4 0 0.4 0.4 195 3 194 305 119 0 119 0 0.5 0 1 0.3 01/07/2005 06:10:00 12.2 0.7 14.1 9.9 11.6 0.7 13.7 9.9 0.4 0 0.4 0.4 194 3 194 305 119 0 119 0 0.4 0 1 0.3 01/07/2005 06:20:00 12.8 0.7 14.9 11.1 12.3 0.8 14.5 9.9 0.4 0 0.4 0.4 194 3 195 305 118 0 119 0 0.4 0 1 0.3 01/07/2005 06:30:00 12.2 0.6 13.7 9.9 11.6 0.8 13.3 8.8 0.4 0 0.4 0.4 196 3 197 305 118 0 118 0 0.3 0 0.8 0.1 01/07/2005 06:40:00 12.1 0.8 14.1 9.9 11.5 0.9 13.7 7.6 0.4 0 0.4 0.4 195 3 198 305 118 0 117 0 0.3 0 0.8 0.1 01/07/2005 06:50:00 12.1 0.7 13.7 9.9 11.5 0.8 13.3 8.4 0.4 0 0.4 0.4 195 3 201 305 117 0 117 0 0.2 0.1 0.8 0.1 01/07/2005 07:00:00 12.2 0.7 14.1 10.3 11.5 0.8 13.7 8.4 0.4 0 0.4 0.4 195 3 194 305 117 0 117 0 0.1 0.1 0.6 0.1 01/07/2005 07:10:00 12 0.5 13.3 10.3 11.2 0.8 13 8.8 0.4 0 0.4 0.4 195 3 196 305 117 1 117 0 0 0 0.6 -0.1 01/07/2005 07:20:00 11.7 0.6 13.3 9.9 11.1 0.7 13 8.8 0.4 0 0.4 0.4 196 3 194 305 117 0 117 0 -0.1 0 0.3 -0.4 01/07/2005 07:30:00 11.6 0.6 13.3 9.9 11 0.8 13 8 0.4 0 0.4 0.4 197 3 198 305 117 0 117 0 -0.2 0 0.3 -0.4 01/07/2005 07:40:00 11 0.6 12.6 9.1 10.4 0.8 12.6 8 0.4 0 0.4 0.4 196 3 196 305 116 0 116 0 -0.2 0 0.3 -0.4 01/07/2005 07:50:00 10.9 0.6 12.6 9.1 10.3 0.7 11.8 8 0.4 0 0.4 0.4 197 3 198 305 116 0 116 0 -0.1 0 0.3 -0.4 01/07/2005 08:00:00 11.6 0.7 13.3 9.5 11 0.9 13.3 8.8 0.4 0 0.4 0.4 196 3 194 305 115 0 115 0 0 0.1 0.6 -0.1 01/07/2005 08:10:00 11.9 0.6 13.7 9.9 11.5 0.7 13.3 9.1 0.4 0 0.4 0.4 198 3 197 305 115 0 115 0 0 0.1 0.6 -0.1 01/07/2005 08:20:00 11.2 0.6 13 9.9 10.7 0.7 12.6 8.8 0.4 0 0.4 0.4 196 3 194 305 114 0 115 0 0 0.1 0.6 -0.4 01/07/2005 08:30:00 10.4 0.6 12.6 9.1 10.1 0.7 11.8 8 0.4 0 0.4 0.4 198 3 198 305 114 0 114 0 -0.1 0 0.6 -0.4 01/07/2005 08:40:00 10 0.6 11.8 8.4 9.6 0.7 11.5 7.6 0.4 0 0.4 0.4 194 3 197 305 114 0 114 0 -0.1 0 0.6 -0.4 01/07/2005 08:50:00 10.1 0.5 11.5 8.8 9.7 0.6 11.1 7.6 0.4 0 0.4 0.4 193 3 198 305 114 0 114 0 -0.2 0 0.3 -0.4 01/07/2005 09:00:00 9.4 0.7 11.5 8 9.1 0.7 11.1 6.8 0.4 0 0.4 0.4 193 4 193 305 114 0 114 0 -0.2 0 0.1 -0.4 01/07/2005 09:10:00 9.3 0.5 10.7 8 9.1 0.6 10.7 7.2 0.4 0 0.4 0.4 192 3 188 305 114 0 114 0 -0.2 0 0.1 -0.4 01/07/2005 09:20:00 9.3 0.5 10.7 7.6 9.1 0.6 10.7 6.5 0.4 0 0.4 0.4 193 3 195 305 114 0 114 0 -0.3 0 -0.1 -0.4 01/07/2005 09:30:00 9.7 0.6 11.5 8 9.4 0.6 11.5 7.6 0.4 0 0.4 0.4 194 3 197 305 114 0 114 0 -0.3 0 -0.1 -0.4 01/07/2005 09:40:00 9.8 0.5 11.1 8.4 9.5 0.6 11.1 7.2 0.4 0 0.4 0.4 192 3 194 305 114 0 114 0 -0.3 0 -0.1 -0.4 01/07/2005 09:50:00 9.5 0.6 11.5 7.6 9.2 0.6 11.1 7.6 0.4 0 0.4 0.4 192 4 194 305 114 0 114 0 -0.3 0 0.1 -0.4 01/07/2005 10:00:00 9.2 0.6 11.5 7.2 9 0.7 11.5 6.8 0.4 0 0.4 0.4 192 3 193 305 116 0 117 0 -0.3 0 0.3 -0.4 01/07/2005 10:10:00 8.9 0.6 10.7 6.8 8.6 0.6 10.3 6.8 0.4 0 0.4 0.4 196 4 198 305 116 0 116 0 -0.3 0 0.3 -0.4 01/07/2005 10:20:00 8.9 0.5 10.3 7.6 8.6 0.5 9.9 6.8 0.4 0 0.4 0.4 199 3 194 305 116 0 116 0 -0.3 0 0.1 -0.4 01/07/2005 10:30:00 8.8 0.5 9.9 8 8.4 0.5 9.5 6.8 0.4 0 0.4 0.4 200 3 196 305 116 0 116 0 -0.4 0.1 0.1 -0.6 01/07/2005 10:40:00 9.3 0.8 11.8 7.6 8.8 0.8 11.8 6.8 0.4 0 0.4 0.4 201 4 211 305 116 0 116 0 -0.4 0.1 0.1 -0.6 01/07/2005 10:50:00 9.8 0.6 11.5 8.4 9.4 0.6 11.1 7.6 0.4 0 0.4 0.4 201 3 196 305 115 0 115 0 -0.4 0.1 0.1 -0.6 01/07/2005 11:00:00 9.9 0.6 11.5 8.4 9.5 0.7 11.1 7.2 0.4 0 0.4 0.4 201 4 197 305 116 0 116 0 -0.4 0.1 0.1 -0.6 01/07/2005 11:10:00 9.2 0.5 10.3 8 8.9 0.5 10.3 7.2 0.4 0 0.4 0.4 201 3 198 305 116 0 116 0 -0.5 0.1 0.1 -0.6 01/07/2005 11:20:00 8.5 0.5 9.9 6.8 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 200 3 199 305 115 0 116 0 -0.5 0.1 0.1 -0.6 01/07/2005 11:30:00 8.9 0.5 10.3 7.6 8.7 0.5 9.9 6.8 0.4 0 0.4 0.4 201 3 206 305 115 0 116 0 -0.4 0.1 0.1 -0.6 01/07/2005 11:40:00 9.2 0.5 10.3 8 8.8 0.5 10.7 7.2 0.4 0 0.4 0.4 201 3 197 305 116 0 116 0 -0.4 0.1 0.1 -0.6 01/07/2005 11:50:00 9.5 0.5 11.5 8.4 9.2 0.5 10.7 8 0.4 0 0.4 0.4 200 3 201 305 115 0 115 0 -0.4 0.1 0.1 -0.6 01/07/2005 12:00:00 9.5 0.6 11.1 8.4 9.2 0.6 11.1 7.6 0.4 0 0.4 0.4 202 3 203 305 115 0 116 0 -0.4 0.1 0.1 -0.6 01/07/2005 12:10:00 9.7 0.6 11.1 8 9.4 0.6 11.1 7.6 0.4 0 0.4 0.4 204 3 203 305 115 0 115 0 -0.5 0.1 0.1 -0.6 01/07/2005 12:20:00 9.5 0.5 10.7 8.4 9 0.6 11.1 7.2 0.4 0 0.4 0.4 201 3 200 305 115 0 114 0 -0.5 0 0.1 -0.6 01/07/2005 12:30:00 9.1 0.6 10.7 7.6 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 201 3 202 305 115 0 115 0 -0.6 0 0.1 -0.6 01/07/2005 12:40:00 8.2 0.5 9.9 6.5 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 198 3 203 305 115 0 115 0 -0.5 0 0.1 -0.6 01/07/2005 12:50:00 8 0.6 9.1 6.1 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 196 3 194 305 115 0 115 0 -0.5 0 0.1 -0.6 01/07/2005 13:00:00 8.6 0.5 9.9 6.8 8.3 0.6 9.5 6.5 0.4 0 0.4 0.4 195 4 201 305 116 0 117 0 -0.5 0 0.1 -0.6 01/07/2005 13:10:00 9.4 0.7 11.1 7.6 9 0.8 10.7 6.1 0.4 0 0.4 0.4 197 4 200 305 116 0 116 0 -0.5 0 -0.4 -0.6 01/07/2005 13:20:00 10 0.6 11.5 8.4 9.6 0.6 11.1 8 0.4 0 0.4 0.4 200 4 204 305 116 0 116 0 -0.5 0 -0.4 -0.6 01/07/2005 13:30:00 10 0.6 11.1 8.4 9.4 0.7 11.1 7.6 0.4 0 0.4 0.4 201 3 203 305 116 0 116 0 -0.6 0 -0.6 -0.6 01/07/2005 13:40:00 9.3 0.6 11.1 8 8.9 0.6 10.7 7.6 0.4 0 0.4 0.4 203 4 206 305 116 0 116 0 -0.6 0 -0.4 -0.6 01/07/2005 13:50:00 8.9 0.5 10.3 7.6 8.6 0.6 9.9 7.2 0.4 0 0.4 0.4 211 4 213 305 116 0 116 0 -0.6 0 -0.6 -0.6 01/07/2005 14:00:00 9 0.6 10.7 7.6 8.3 0.7 10.3 6.1 0.4 0 0.4 0.4 213 0 213 305 116 0 117 0 -0.6 0 -0.6 -0.6 01/07/2005 14:10:00 9 0.6 10.3 6.8 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.6 0 -0.1 -0.6 01/07/2005 14:20:00 9.3 0.6 11.1 7.6 8.8 0.7 10.3 6.8 0.4 0 0.4 0.4 213 0 213 305 116 0 117 0 -0.7 0 -0.6 -0.6 01/07/2005 14:30:00 8.9 0.5 10.3 7.6 8.4 0.6 10.3 6.1 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.7 0 -0.6 -0.8 01/07/2005 14:40:00 8.8 0.6 10.3 7.2 8.2 0.7 10.3 6.1 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.8 0 -0.6 -1.1 01/07/2005 14:50:00 8.4 0.5 9.5 6.8 8 0.7 9.9 6.1 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.7 0 -0.6 -1.1 01/07/2005 15:00:00 7.8 0.5 9.1 6.8 7.3 0.6 8.8 6.1 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.8 0 -0.6 -0.8 01/07/2005 15:10:00 8 0.5 9.5 6.8 7.5 0.6 9.5 5.7 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.8 0 -0.4 -0.8 01/07/2005 15:20:00 7.7 0.4 8.8 6.8 7.5 0.6 8.8 6.1 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.8 0 -0.4 -0.8 01/07/2005 15:30:00 7.7 0.4 8.8 6.1 7.5 0.5 8.8 5.7 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.8 0 -0.4 -1.1 01/07/2005 15:40:00 8 0.5 9.9 6.8 8.1 0.6 9.9 6.1 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.7 0 -0.1 -0.8 01/07/2005 15:50:00 8.1 0.5 9.5 7.2 8 0.6 9.9 6.5 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.6 0 -0.1 -0.6 01/07/2005 16:00:00 8.2 0.6 9.9 6.8 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.6 0 -0.1 -0.6 01/07/2005 16:10:00 8.4 0.6 10.3 6.5 8.2 0.7 10.3 5.3 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.7 0 -0.4 -0.8 01/07/2005 16:20:00 8.8 0.7 10.7 6.8 8.8 0.7 11.1 6.8 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.8 0 -0.4 -1.1 01/07/2005 16:30:00 8.3 0.6 9.9 6.8 8.4 0.6 10.3 6.5 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.9 0 -0.4 -1.1 01/07/2005 16:40:00 7.9 0.6 9.5 6.1 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 213 0 213 305 116 0 116 0 -0.8 0 -0.4 -0.8 01/07/2005 16:50:00 7.9 0.5 9.1 6.8 7.9 0.5 9.1 6.1 0.4 0 0.4 0.4 213 0 213 305 116 0 117 0 -0.7 0 -0.4 -0.8 01/07/2005 17:00:00 8 0.5 9.9 6.5 7.9 0.6 9.9 6.1 0.4 0 0.4 0.4 213 0 213 305 116 0 117 0 -0.6 0 -0.6 -0.6 01/07/2005 17:10:00 7.8 0.7 9.1 5.7 7.7 0.7 9.5 6.1 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.5 0.1 0.1 -0.6 01/07/2005 17:20:00 7.9 0.6 9.5 6.5 7.8 0.7 9.5 5.7 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.3 0 0.3 -0.4 01/07/2005 17:30:00 8.4 0.5 9.9 6.8 8 0.7 9.5 6.1 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.3 0 0.1 -0.4 01/07/2005 17:40:00 8.3 0.5 9.5 7.2 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.3 0 0.1 -0.4 01/07/2005 17:50:00 8.3 0.5 9.5 6.8 7.9 0.6 9.5 6.1 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.3 0 0.1 -0.4 01/07/2005 18:00:00 8.4 0.5 9.5 6.5 8.1 0.6 9.5 5.7 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.3 0 0.1 -0.4 01/07/2005 18:10:00 8.3 0.5 9.9 6.8 8 0.6 9.5 6.5 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.2 0 0.1 -0.4 01/07/2005 18:20:00 8.8 0.5 9.9 6.8 8.4 0.6 9.9 6.5 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.2 0 0.1 -0.4 01/07/2005 18:30:00 8.7 0.5 10.3 7.2 8.3 0.7 9.9 5.7 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.3 0 0.1 -0.4 01/07/2005 18:40:00 8.6 0.5 9.9 6.8 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.3 0 0.1 -0.4 01/07/2005 18:50:00 8.9 0.6 10.3 7.2 8.4 0.7 10.3 6.1 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.3 0 -0.1 -0.4 01/07/2005 19:00:00 9.7 0.5 11.1 8 9.2 0.7 10.7 6.5 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.3 0 -0.1 -0.4 01/07/2005 19:10:00 9.9 0.6 11.1 8.4 9.3 0.7 11.1 7.2 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.3 0 -0.1 -0.4 01/07/2005 19:20:00 9.5 0.6 10.7 7.6 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 213 0 213 305 118 0 117 0 -0.4 0 -0.4 -0.4 01/07/2005 19:30:00 9.7 0.5 11.1 8.4 9.4 0.6 10.7 7.6 0.4 0 0.4 0.4 213 0 213 305 118 0 117 0 -0.4 0 -0.4 -0.6 01/07/2005 19:40:00 9.5 0.6 11.5 7.6 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.5 0 -0.4 -0.6 01/07/2005 19:50:00 9.6 0.6 11.1 8 9.3 0.7 11.1 7.2 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.6 0 -0.1 -0.6 01/07/2005 20:00:00 9.8 0.5 11.1 8.4 9.5 0.7 11.5 7.2 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.7 0 -0.1 -0.8 01/07/2005 20:10:00 9.5 0.6 11.5 8.4 9.4 0.8 11.5 6.8 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.8 0 -0.4 -1.1 01/07/2005 20:20:00 9.2 0.6 10.7 7.2 8.9 0.6 10.7 6.5 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -0.9 0 -0.4 -1.1 01/07/2005 20:30:00 8.8 0.6 10.3 7.2 8.5 0.6 10.3 6.5 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -1 0.1 -0.4 -1.1 01/07/2005 20:40:00 8.1 0.5 9.1 6.8 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -1 0 -0.8 -1.1 01/07/2005 20:50:00 7.9 0.4 9.1 6.8 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -1 0 -0.8 -1.1 01/07/2005 21:00:00 7.8 0.5 8.8 6.5 7.7 0.6 8.8 5.7 0.4 0 0.4 0.4 213 0 213 305 118 0 117 0 -1.1 0 -1.1 -1.1 01/07/2005 21:10:00 7.3 0.4 8.4 6.5 7.3 0.5 8.4 6.1 0.4 0 0.4 0.4 213 0 213 305 118 0 117 0 -1.1 0 -1.1 -1.1 01/07/2005 21:20:00 7.8 0.5 9.1 6.1 7.8 0.7 9.5 5.7 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1.1 0 -0.6 -1.1 01/07/2005 21:30:00 8.2 0.6 9.5 5.7 8.3 0.7 9.9 6.1 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1.1 0 -0.6 -1.1 01/07/2005 21:40:00 7.7 0.5 9.1 6.5 7.7 0.6 9.1 5.7 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1.1 0 -1.1 -1.1 01/07/2005 21:50:00 7.1 0.5 8.4 5.7 7.3 0.6 8.8 5.3 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1.1 0 -1.1 -1.3 01/07/2005 22:00:00 6.6 0.4 8 5.3 6.8 0.5 8 4.9 0.4 0 0.4 0.4 213 0 213 305 119 1 114 0 -1.1 0 -1.1 -1.1 01/07/2005 22:10:00 6.4 0.5 8 5.3 6.5 0.6 8 4.6 0.4 0 0.4 0.4 213 0 213 305 120 0 120 0 -1.1 0 -1.1 -1.1 01/07/2005 22:20:00 6.4 0.4 7.6 4.9 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 213 0 213 305 120 0 120 0 -1.1 0 -1.1 -1.1 01/07/2005 22:30:00 6.3 0.3 7.2 5.7 6.6 0.4 7.6 5.3 0.4 0 0.4 0.4 213 0 213 305 121 0 121 0 -1.1 0 -0.8 -1.1 01/07/2005 22:40:00 6.7 0.4 7.6 5.7 6.9 0.5 8 4.9 0.4 0 0.4 0.4 213 0 213 305 122 0 122 0 -1.1 0 -1.1 -1.1 01/07/2005 22:50:00 6.6 0.5 7.6 5.3 6.7 0.5 8 4.9 0.4 0 0.4 0.4 213 0 213 305 122 0 122 0 -1.1 0 -1.1 -1.1 01/07/2005 23:00:00 6.9 0.5 8.8 5.7 7 0.5 8.8 5.3 0.4 0 0.4 0.4 213 0 213 305 121 0 121 0 -1 0 -0.8 -1.1 01/07/2005 23:10:00 7.1 0.4 8.4 5.7 7.2 0.5 8.4 5.3 0.4 0 0.4 0.4 213 0 213 305 121 0 121 0 -1 0 -0.8 -1.1 01/07/2005 23:20:00 7.1 0.4 8 5.7 7.1 0.5 8.4 4.9 0.4 0 0.4 0.4 213 0 213 305 120 0 121 0 -1 0 -0.8 -1.1 01/07/2005 23:30:00 7 0.4 8 6.1 6.9 0.5 8 5.3 0.4 0 0.4 0.4 213 0 213 305 119 0 119 0 -1 0 -0.8 -1.1 01/07/2005 23:40:00 6.7 0.4 7.6 5.7 6.7 0.5 8.4 5.3 0.4 0 0.4 0.4 213 0 213 305 119 0 119 0 -1.1 0 -0.8 -1.1 01/07/2005 23:50:00 6.4 0.4 7.2 5.3 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 213 0 213 305 119 0 119 0 -1.1 0 -1.1 -1.3 01/08/2005 00:00:00 6.4 0.4 7.6 5.3 6.4 0.5 7.6 5.3 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1.1 0 -0.6 -1.3 01/08/2005 00:10:00 6.4 0.4 7.2 4.9 6.3 0.5 7.2 3.8 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1.1 0 -0.6 -1.3 01/08/2005 00:20:00 6.3 0.4 7.6 4.9 6.2 0.5 7.6 4.2 0.4 0 0.4 0.4 213 0 213 305 118 0 117 0 -1.1 0 -0.6 -1.3 01/08/2005 00:30:00 6.4 0.5 7.6 4.9 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -1.2 0 -0.6 -1.3 01/08/2005 00:40:00 6.4 0.5 7.6 4.9 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 213 0 213 305 118 0 117 0 -1.2 0 -0.6 -1.3 01/08/2005 00:50:00 5.8 0.4 7.2 4.9 5.6 0.5 6.5 4.2 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1.3 0 -0.8 -1.3 01/08/2005 01:00:00 6.4 0.5 7.6 5.3 6.2 0.5 7.6 5.3 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -1.3 0 -0.8 -1.3 01/08/2005 01:10:00 6.6 0.5 8 5.3 6.4 0.6 8 4.9 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -1.3 0 -0.8 -1.3 01/08/2005 01:20:00 6.4 0.4 7.6 4.9 6.1 0.5 7.6 4.6 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -1.2 0 -0.6 -1.3 01/08/2005 01:30:00 6 0.5 7.6 4.9 5.7 0.6 7.2 4.2 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -1.3 0 -0.8 -1.3 01/08/2005 01:40:00 5.5 0.4 6.5 4.6 5.3 0.5 6.8 4.2 0.4 0 0.4 0.4 213 0 213 305 117 0 117 0 -1.4 0 -0.8 -1.5 01/08/2005 01:50:00 4.8 0.4 5.7 3.8 4.9 0.5 6.1 3.4 0.4 0 0.4 0.4 213 0 213 305 117 1 117 0 -1.4 0 -0.8 -1.5 01/08/2005 02:00:00 4.5 0.4 6.1 3.8 4.7 0.6 6.5 3.4 0.4 0 0.4 0.4 213 0 213 305 119 1 119 0 -1.4 0 -0.8 -1.5 01/08/2005 02:10:00 4.2 0.4 5.7 3.4 4.4 0.5 5.7 3 0.4 0 0.4 0.4 213 0 213 305 119 0 120 0 -1.4 0 -0.8 -1.5 01/08/2005 02:20:00 3.9 0.3 4.9 3.4 4.3 0.4 5.3 3 0.4 0 0.4 0.4 213 0 213 305 119 0 119 0 -1.4 0 -0.8 -1.5 01/08/2005 02:30:00 3.9 0.3 4.6 3 4.4 0.3 5.3 3.8 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1.4 0 -0.8 -1.5 01/08/2005 02:40:00 4 0.2 4.6 3.4 4.6 0.4 5.3 3.4 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1.4 0 -0.8 -1.5 01/08/2005 02:50:00 3.8 0.3 4.6 3 4.4 0.5 5.7 3 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1.4 0 -0.8 -1.5 01/08/2005 03:00:00 3.4 0.4 4.2 2.3 4.1 0.5 5.3 2.6 0.4 0 0.4 0.4 213 0 213 305 119 0 119 0 -1.3 0 -0.8 -1.3 01/08/2005 03:10:00 3 0.2 3.8 2.3 3.8 0.4 4.6 2.6 0.4 0 0.4 0.4 213 0 213 305 119 0 118 0 -1.2 0 -1.1 -1.3 01/08/2005 03:20:00 3.1 0.3 3.8 2.3 4.2 0.5 5.3 3 0.4 0 0.4 0.4 213 0 213 305 119 0 119 0 -1.2 0 -1.1 -1.3 01/08/2005 03:30:00 3 0.3 3.8 1.9 4.2 0.4 5.3 2.6 0.4 0 0.4 0.4 213 0 213 305 119 0 119 0 -1.2 0 -1.1 -1.3 01/08/2005 03:40:00 2.8 0.4 3.8 1.9 4.2 0.5 5.7 2.6 0.4 0 0.4 0.4 213 0 213 305 119 0 119 0 -1.1 0 -0.6 -1.3 01/08/2005 03:50:00 2.3 0.4 3 1.5 4 0.4 4.9 2.6 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1.1 0 -1.1 -1.1 01/08/2005 04:00:00 0.5 0.4 1.9 0.4 3.5 0.5 4.6 1.9 0.4 0 0.4 0.4 213 0 213 305 118 0 118 0 -1 0.1 -0.6 -1.1 01/08/2005 04:10:00 0.4 0 0.4 0.4 3.2 0.5 4.2 2.3 0.4 0 0.4 0.4 213 0 305 305 118 0 118 0 -1.1 0 -0.6 -1.1 01/08/2005 04:20:00 0.4 0 0.4 0.4 3.4 0.4 4.2 2.3 0.4 0 0.4 0.4 213 0 305 305 117 0 117 0 -1.1 0.1 -0.6 -1.1 01/08/2005 04:30:00 0.4 0 0.4 0.4 3.3 0.4 4.2 2.3 0.4 0 0.4 0.4 213 0 305 305 117 0 117 0 -1 0 -0.6 -1.1 01/08/2005 04:40:00 0.4 0 0.4 0.4 2.7 0.4 3.4 1.5 0.4 0 0.4 0.4 213 0 305 305 117 0 117 0 -1 0 -0.6 -1.1 01/08/2005 04:50:00 0.4 0 0.4 0.4 2 0.8 3 0.4 0.4 0 0.4 0.4 213 0 305 305 116 0 116 0 -1.1 0 -0.6 -1.1 01/08/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 116 0 0 0 -1 0 -0.6 -1.1 01/08/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 117 0 0 0 -1.1 0 -0.8 -1.1 01/08/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 117 0 0 0 -1.1 0 -0.8 -1.1 01/08/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 118 0 0 0 -1.1 0 -0.6 -1.1 01/08/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 117 1 0 0 -1 0 -0.6 -1.1 01/08/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 118 1 0 0 -1 0 -0.6 -1.1 01/08/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 118 0 0 0 -1 0 -0.6 -1.1 01/08/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 119 0 0 0 -1 0 -0.6 -1.1 01/08/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 119 0 0 0 -0.9 0 -0.4 -1.1 01/08/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 120 0 0 0 -1 0 -0.6 -1.1 01/08/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 119 0 0 0 -1 0.1 -0.6 -1.1 01/08/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 119 0 0 0 -1 0 -0.6 -1.1 01/08/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 120 0 0 0 -1 0 -0.8 -1.1 01/08/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 121 0 0 0 -1 0 -0.6 -1.1 01/08/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 121 0 0 0 -1 0 -0.8 -1.1 01/08/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 121 0 0 0 -1 0 -0.8 -1.1 01/08/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 122 0 0 0 -1 0 -0.6 -1.1 01/08/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 122 0 0 0 -1 0 -0.8 -1.1 01/08/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 122 0 0 0 -1 0 -0.4 -1.1 01/08/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 122 0 0 0 -1 0.1 -0.4 -1.1 01/08/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 122 0 0 0 -1 0.1 -0.4 -1.1 01/08/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 122 0 0 0 -1 0 -0.6 -1.1 01/08/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 122 0 0 0 -1 0.1 -0.4 -1.1 01/08/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 122 0 0 0 -1 0 -0.6 -1.1 01/08/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 122 0 0 0 -1 0 -0.8 -1.1 01/08/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 122 0 0 0 -1.1 0 -0.8 -1.3 01/08/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 120 1 0 0 -1.2 0 -0.6 -1.3 01/08/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 119 0 0 0 -1.4 0 -1.1 -1.8 01/08/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 120 1 0 0 -1.6 0 -1.1 -1.8 01/08/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 120 0 0 0 -1.7 0 -1.3 -1.8 01/08/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 120 1 0 0 -1.9 0.2 -1.3 -2.2 01/08/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 119 0 0 0 -2.2 0 -1.8 -2.4 01/08/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 117 1 0 0 -2.6 0.1 -2 -2.7 01/08/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 116 0 0 0 -2.6 0 -2 -2.7 01/08/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 114 0 0 0 -2.5 0 -2 -2.7 01/08/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 115 0 0 0 -2.4 0 -2 -2.7 01/08/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 113 1 0 0 -2.5 0 -2.4 -2.7 01/08/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 111 1 0 0 -2.7 0 -2.4 -2.7 01/08/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 110 1 0 0 -2.6 0 -2.4 -2.7 01/08/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 112 1 0 0 -2.5 0 -2.2 -2.7 01/08/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 113 0 0 0 -2.4 0 -2 -2.4 01/08/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 114 0 0 0 -2.3 0 -2 -2.4 01/08/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 118 2 0 0 -2 0 -1.3 -2.2 01/08/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 118 3 0 0 -2.6 0.3 -1.8 -3.1 01/08/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 108 2 0 0 -3.3 0.2 -3.1 -3.8 01/08/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 102 1 0 0 -3.8 0 -3.6 -4 01/08/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 99 1 0 0 -4.1 0.1 -3.8 -4.2 01/08/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 97 0 0 0 -4.3 0 -4 -4.5 01/08/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 97 1 0 0 -4.1 0 -3.8 -4.2 01/08/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 97 0 0 0 -4.1 0 -4 -4.2 01/08/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 97 0 0 0 -4 0 -3.8 -4 01/08/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 97 1 0 0 -4 0 -3.8 -4.2 01/08/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 94 1 0 0 -4.1 0 -3.8 -4.2 01/08/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 92 0 0 0 -4.1 0.1 -4 -4.5 01/08/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 90 0 0 0 -4.2 0 -3.8 -4.5 01/08/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 90 1 0 0 -4.2 0.1 -3.6 -4.5 01/08/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 91 0 0 0 -4.4 0 -4.2 -4.5 01/08/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 92 0 0 0 -4.4 0 -4.2 -4.5 01/08/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 91 1 0 0 -4.6 0.1 -4.5 -4.7 01/08/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 91 1 0 0 -4.6 0 -4.5 -4.7 01/08/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 95 1 0 0 -4.5 0 -4 -4.7 01/08/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 90 1 0 0 -4.9 0 -4.7 -5.1 01/08/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 84 1 0 0 -5.3 0.1 -4.9 -5.6 01/08/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 81 0 0 0 -5.5 0 -5.3 -5.6 01/08/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 80 0 0 0 -5.5 0 -5.3 -5.8 01/08/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 80 0 0 0 -5.4 0 -5.1 -5.6 01/08/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 80 1 0 0 -5.5 0 -4.7 -5.6 01/08/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 77 1 0 0 -5.6 0 -5.6 -5.8 01/08/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 76 0 0 0 -5.6 0 -5.6 -5.8 01/08/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 74 1 0 0 -5.8 0 -5.6 -6 01/08/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 72 1 0 0 -5.9 0 -5.8 -6 01/08/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 70 0 0 0 -5.9 0 -5.8 -6 01/08/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 70 0 0 0 -5.9 0 -5.8 -6 01/08/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 71 1 0 0 -5.9 0.1 -5.6 -6 01/08/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 70 0 0 0 -6.1 0 -6 -6.4 01/08/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 68 0 0 0 -6.3 0 -6 -6.4 01/08/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 67 0 0 0 -6.3 0 -6.2 -6.7 01/08/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 65 0 0 0 -6.5 0 -6.2 -6.7 01/08/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 65 0 0 0 -6.5 0 -6.2 -6.7 01/08/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 305 305 64 0 0 0 -6.7 0 -6.7 -6.9 01/08/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 62 1 0 0 -6.9 0.1 -6.7 -7.1 01/08/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 60 0 0 0 -7 0 -6.9 -7.3 01/08/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 60 0 0 0 -7.1 0 -6.9 -7.3 01/08/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 59 0 0 0 -7.4 0.1 -7.1 -7.7 01/08/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 51 2 0 0 -7.6 0 -7.3 -7.7 01/08/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 49 0 0 0 -7.6 0 -6.9 -7.9 01/08/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 48 0 0 0 -7.8 0 -7.7 -7.9 01/08/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 46 0 0 0 -8 0 -7.7 -8.2 01/08/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 45 0 0 0 -8.1 0.1 -7.7 -8.2 01/08/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 45 0 0 0 -8.1 0 -7.7 -8.2 01/08/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 43 0 0 0 -8.2 0 -7.7 -8.4 01/08/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 43 0 0 0 -8.3 0 -7.7 -8.6 01/08/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 41 0 0 0 -8.5 0 -7.9 -8.8 01/08/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 40 0 0 0 -8.7 0 -8.4 -8.8 01/08/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 39 0 0 0 -8.7 0 -8.2 -8.8 01/08/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 38 0 0 0 -8.8 0 -8.2 -9 01/08/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 37 0 0 0 -8.9 0 -8.8 -9 01/08/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 36 0 0 0 -9 0 -8.8 -9.2 01/08/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 36 0 0 0 -9 0 -8.8 -9.2 01/08/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 36 0 0 0 -9.1 0.1 -8.8 -9.2 01/08/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 36 0 0 0 -9.2 0 -9 -9.2 01/08/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 214 0 305 305 36 0 0 0 -9.2 0 -9 -9.4 01/08/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 36 0 0 0 -9.3 0 -9 -9.4 01/08/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 36 0 0 0 -9.3 0 -9.2 -9.4 01/08/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 36 0 0 0 -9.4 0 -9.2 -9.6 01/08/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 35 0 0 0 -9.5 0 -9.2 -9.6 01/08/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 34 0 0 0 -9.5 0 -9.2 -9.6 01/08/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 35 0 0 0 -9.5 0 -9.4 -9.6 01/08/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 34 0 0 0 -9.6 0 -9.2 -9.8 01/08/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 34 0 0 0 -9.6 0 -9.2 -9.6 01/08/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 35 0 0 0 -9.7 0 -9.4 -9.8 01/08/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 34 0 0 0 -9.8 0 -9.6 -10 01/08/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 34 0 0 0 -9.8 0 -9.6 -10 01/08/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 33 0 0 0 -10 0 -9.8 -10 01/09/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 32 0 0 0 -10 0 -9.4 -10.2 01/09/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 32 0 0 0 -10.1 0 -9.6 -10.2 01/09/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 32 0 0 0 -10.2 0 -9.8 -10.4 01/09/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 32 0 0 0 -10.2 0 -9.8 -10.4 01/09/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 32 0 0 0 -10.2 0 -9.8 -10.4 01/09/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 32 0 0 0 -10.2 0.1 -9.8 -10.4 01/09/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 32 0 0 0 -10.2 0.1 -9.8 -10.4 01/09/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.3 0 -10 -10.4 01/09/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.3 0 -9.8 -10.4 01/09/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.3 0 -9.8 -10.4 01/09/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.4 0 -9.8 -10.4 01/09/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.3 0.1 -9.6 -10.4 01/09/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.3 0 -9.8 -10.4 01/09/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.3 0 -9.8 -10.4 01/09/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.3 0 -9.8 -10.4 01/09/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.4 0 -10 -10.4 01/09/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.4 0 -10 -10.4 01/09/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.4 0 -10 -10.7 01/09/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.4 0 -10 -10.7 01/09/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.4 0 -10 -10.7 01/09/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.4 0 -10.2 -10.7 01/09/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.4 0 -10.2 -10.4 01/09/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.4 0 -10.2 -10.7 01/09/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 31 0 0 0 -10.4 0 -10.2 -10.9 01/09/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 30 0 0 0 -10.5 0 -10.2 -10.9 01/09/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 30 0 0 0 -10.5 0 -10 -10.9 01/09/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 30 0 0 0 -10.5 0 -10 -10.7 01/09/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 30 0 0 0 -10.6 0 -10.2 -10.9 01/09/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 30 0 0 0 -10.5 0 -10 -10.9 01/09/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 30 0 0 0 -10.7 0 -10.2 -10.9 01/09/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 30 0 0 0 -10.7 0 -10.4 -10.9 01/09/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 30 0 0 0 -10.7 0 -10.4 -10.9 01/09/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 30 0 0 0 -10.7 0 -10.4 -10.9 01/09/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 30 0 0 0 -10.7 0 -10.4 -10.9 01/09/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 29 0 0 0 -10.8 0 -10.7 -10.9 01/09/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 29 0 0 0 -10.8 0 -10.4 -10.9 01/09/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 29 0 0 0 -10.8 0 -10.7 -10.9 01/09/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 29 0 0 0 -10.8 0 -10.4 -10.9 01/09/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 29 0 0 0 -10.8 0 -10.7 -10.9 01/09/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 29 0 0 0 -10.8 0 -10.7 -10.9 01/09/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 29 0 0 0 -10.8 0.1 -10.4 -10.9 01/09/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 29 0 0 0 -10.8 0 -10.7 -10.9 01/09/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 28 0 0 0 -10.9 0 -10.7 -11.1 01/09/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 28 0 0 0 -10.9 0 -10.7 -10.9 01/09/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 29 0 0 0 -10.9 0 -10.7 -10.9 01/09/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 29 0 0 0 -10.8 0.1 -10.4 -10.9 01/09/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 29 0 0 0 -10.9 0 -10.7 -11.1 01/09/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 28 0 0 0 -11 0 -10.9 -11.3 01/09/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 28 0 0 0 -11 0 -10.7 -11.3 01/09/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 28 0 0 0 -11.1 0 -10.4 -11.3 01/09/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 27 0 0 0 -11.3 0.1 -10.9 -11.5 01/09/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 27 0 0 0 -11.3 0.1 -10.9 -11.5 01/09/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 27 0 0 0 -11.4 0 -10.9 -11.7 01/09/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 26 0 0 0 -11.5 0 -11.5 -11.7 01/09/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 26 0 0 0 -11.6 0 -11.5 -11.9 01/09/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 26 0 0 0 -11.6 0 -11.5 -11.9 01/09/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 26 0 0 0 -11.7 0.1 -11.5 -12.1 01/09/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 26 0 0 0 -11.8 0 -11.7 -12.1 01/09/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 26 0 0 0 -11.9 0 -11.7 -12.1 01/09/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 25 0 0 0 -11.9 0.1 -11.7 -12.3 01/09/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 25 0 0 0 -12 0 -11.5 -12.1 01/09/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 25 0 0 0 -12.1 0 -11.7 -12.5 01/09/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 25 0 0 0 -12.2 0.1 -11.9 -12.5 01/09/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 24 0 0 0 -12.3 0.1 -12.1 -12.5 01/09/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 24 0 0 0 -12.5 0 -12.1 -12.7 01/09/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 24 0 0 0 -12.5 0 -12.1 -12.7 01/09/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 24 0 0 0 -12.6 0 -12.5 -12.9 01/09/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 24 0 0 0 -12.6 0 -12.5 -12.9 01/09/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 23 0 0 0 -12.6 0.1 -12.3 -12.9 01/09/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 23 0 0 0 -12.8 0 -12.7 -12.9 01/09/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 23 0 0 0 -12.8 0 -12.5 -12.9 01/09/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 23 0 0 0 -12.8 0 -12.5 -12.9 01/09/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 22 0 0 0 -13 0.1 -12.5 -13.3 01/09/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 22 0 0 0 -13.1 0.1 -12.5 -13.3 01/09/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 22 0 0 0 -13.1 0 -12.5 -13.3 01/09/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 22 0 0 0 -13.2 0 -12.9 -13.3 01/09/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 22 0 0 0 -13.2 0.1 -12.5 -13.5 01/09/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 22 0 0 0 -13.3 0.1 -12.9 -13.5 01/09/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 21 0 0 0 -13.5 0 -13.1 -13.7 01/09/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 21 0 0 0 -13.6 0 -13.3 -13.7 01/09/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 21 0 0 0 -13.7 0 -13.3 -13.9 01/09/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 21 0 0 0 -13.7 0 -13.3 -14.1 01/09/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 20 0 0 0 -13.8 0 -13.7 -14.1 01/09/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 20 0 0 0 -13.9 0.1 -13.7 -14.3 01/09/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 20 0 0 0 -14 0.1 -13.7 -14.3 01/09/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 20 0 0 0 -14 0.1 -13.7 -14.3 01/09/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 20 0 0 0 -14.1 0.1 -13.7 -14.3 01/09/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 20 0 0 0 -14.1 0.1 -13.7 -14.3 01/09/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 20 0 0 0 -14.2 0 -13.9 -14.3 01/09/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 19 0 0 0 -14.2 0.1 -13.9 -14.4 01/09/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 20 0 0 0 -14.2 0.2 -13.7 -14.6 01/09/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 19 0 0 0 -14.4 0.1 -14.3 -14.6 01/09/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 19 0 0 0 -14.5 0.1 -14.3 -14.6 01/09/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 19 0 0 0 -14.6 0 -14.4 -14.6 01/09/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 19 0 0 0 -14.6 0 -14.4 -14.8 01/09/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 18 0 0 0 -14.6 0.1 -14.3 -14.6 01/09/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 18 0 0 0 -14.5 0.1 -14.1 -14.6 01/09/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 18 0 0 0 -14.6 0.1 -14.3 -14.6 01/09/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 305 305 18 0 0 0 -14.6 0 -14.1 -14.8 01/09/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 76 305 305 19 0 0 0 -14.7 0 -14.4 -14.8 01/09/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 5 305 305 18 0 0 0 -14.7 0 -14.4 -14.8 01/09/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 6 305 305 18 0 0 0 -14.7 0 -14.3 -14.8 01/09/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 6 305 305 18 0 0 0 -14.7 0 -14.3 -14.8 01/09/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 4 305 305 18 0 0 0 -14.7 0 -14.3 -14.8 01/09/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 4 305 305 18 0 0 0 -14.7 0 -14.4 -14.8 01/09/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 4 305 305 18 0 0 0 -14.8 0 -14.6 -15 01/09/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 5 305 305 18 0 0 0 -14.8 0 -14.6 -15 01/09/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 5 305 305 17 0 0 0 -14.9 0 -14.6 -15 01/09/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 4 305 305 17 0 0 0 -15.2 0 -14.8 -15.2 01/09/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 5 305 305 17 0 0 0 -15.3 0 -15 -15.6 01/09/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 4 305 305 16 0 0 0 -15.3 0 -15 -15.4 01/09/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 49 4 305 305 16 0 0 0 -15.3 0 -15 -15.4 01/09/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 5 305 305 16 0 0 0 -15.2 0 -14.8 -15.4 01/09/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 5 305 305 16 0 0 0 -15.3 0 -15 -15.6 01/09/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 5 305 305 16 0 0 0 -15.4 0 -15.2 -15.6 01/09/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 5 305 305 16 0 0 0 -15.4 0 -15.2 -15.6 01/09/2005 19:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 3 38 305 16 0 0 0 -15.7 0.1 -15.4 -15.8 01/09/2005 19:30:00 0.4 0.2 3.8 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 5 57 305 16 0 0 0 -15.6 0 -15.4 -15.8 01/09/2005 19:40:00 0.4 0.1 1.9 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 5 48 305 15 0 0 0 -15.7 0 -15.6 -15.8 01/09/2005 19:50:00 0.4 0.1 2.3 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 5 48 305 15 0 0 0 -15.8 0 -15.6 -16 01/09/2005 20:00:00 0.4 0.2 3 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 6 53 305 15 0 0 0 -15.8 0 -15.2 -16 01/09/2005 20:10:00 0.4 0.1 2.3 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 49 5 54 305 15 0 0 0 -15.9 0 -15.4 -16.2 01/09/2005 20:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 5 37 305 15 0 0 0 -15.9 0 -15.6 -16 01/09/2005 20:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 5 49 305 15 0 0 0 -15.9 0 -15.6 -16.2 01/09/2005 20:40:00 0.4 0.2 2.3 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 5 53 305 15 0 0 0 -16 0.1 -15.6 -16.4 01/09/2005 20:50:00 0.4 0.1 2.3 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 5 49 305 14 0 0 0 -16.1 0 -15.8 -16.2 01/09/2005 21:00:00 0.5 0.5 3.8 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 5 33 305 14 0 0 0 -16.1 0.1 -15.6 -16.4 01/09/2005 21:10:00 0.4 0.3 3.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 5 48 305 14 0 0 0 -16.1 0 -16 -16.2 01/09/2005 21:20:00 0.4 0.2 3.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 5 38 305 14 0 0 0 -16 0 -15.8 -16.2 01/09/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 49 5 305 305 14 0 0 0 -16.1 0 -15.8 -16.2 01/09/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 5 305 305 14 0 0 0 -16.2 0 -16 -16.4 01/09/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 4 305 305 14 0 0 0 -16.1 0.1 -15.8 -16.4 01/09/2005 22:00:00 0.4 0 0.4 0.4 5.7 3.3 8 0.4 0.4 0 0.4 0.4 43 7 305 305 14 0 14 0 -16.1 0.1 -15.6 -16.4 01/09/2005 22:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 42 5 305 305 14 0 14 0 -16.3 0 -16 -16.4 01/09/2005 22:20:00 0.4 0 0.4 0.4 7.7 0.2 8 7.2 0.4 0 0.4 0.4 43 6 305 305 14 0 14 0 -16.3 0 -16 -16.4 01/09/2005 22:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 48 5 305 305 14 0 14 0 -16.4 0 -16.2 -16.6 01/09/2005 22:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 38 4 305 305 14 0 14 0 -16.4 0 -16 -16.6 01/09/2005 22:50:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 42 6 305 305 14 0 14 0 -16.4 0 -16 -16.6 01/09/2005 23:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 42 6 305 305 14 0 14 0 -16.4 0 -16.2 -16.6 01/09/2005 23:10:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 41 5 305 305 13 0 13 0 -16.6 0.1 -16.4 -16.9 01/09/2005 23:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 44 5 305 305 13 0 13 0 -16.7 0.1 -16.4 -16.9 01/09/2005 23:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 41 4 305 305 13 0 13 0 -16.9 0 -16.6 -16.9 01/09/2005 23:40:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 44 5 305 305 12 0 13 0 -16.9 0 -16.9 -16.9 01/09/2005 23:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 41 5 305 305 12 0 12 0 -17 0 -16.9 -17.1 01/10/2005 00:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 40 5 305 305 12 0 13 0 -16.9 0 -16.6 -16.9 01/10/2005 00:10:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 40 5 305 305 12 0 12 0 -17 0 -16.6 -17.3 01/10/2005 00:20:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 45 5 305 305 12 0 12 0 -17 0 -16.6 -17.1 01/10/2005 00:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 47 5 305 305 12 0 12 0 -17.1 0 -16.9 -17.3 01/10/2005 00:40:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 42 5 305 305 12 0 12 0 -17.1 0 -16.6 -17.3 01/10/2005 00:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 41 6 305 305 12 0 12 0 -17.1 0 -16.9 -17.3 01/10/2005 01:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 43 5 305 305 12 0 12 0 -17.2 0 -16.9 -17.3 01/10/2005 01:10:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 39 6 305 305 12 0 12 0 -17.1 0.1 -16.6 -17.5 01/10/2005 01:20:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 43 7 305 305 12 0 12 0 -17.2 0 -16.9 -17.3 01/10/2005 01:30:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 47 7 305 305 12 0 11 0 -17.2 0 -16.9 -17.3 01/10/2005 01:40:00 0.4 0 0.4 0.4 7.7 0.2 8.4 7.2 0.4 0 0.4 0.4 43 7 305 305 11 0 11 0 -17.3 0.1 -16.9 -17.3 01/10/2005 01:50:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 43 7 305 305 11 0 11 0 -17.2 0.1 -16.9 -17.3 01/10/2005 02:00:00 0.4 0 0.4 0.4 7.7 0.2 8.4 6.8 0.4 0 0.4 0.4 44 6 305 305 11 0 11 0 -17.2 0 -16.9 -17.3 01/10/2005 02:10:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 44 6 305 305 11 0 11 0 -17.2 0 -16.9 -17.3 01/10/2005 02:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 45 7 305 305 11 0 11 0 -17.2 0 -16.9 -17.3 01/10/2005 02:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 46 6 305 305 11 0 11 0 -17.3 0 -16.9 -17.5 01/10/2005 02:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 48 5 305 305 11 0 11 0 -17.3 0 -16.9 -17.5 01/10/2005 02:50:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 47 7 305 305 11 0 11 0 -17.3 0 -16.9 -17.5 01/10/2005 03:00:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 49 7 305 305 11 0 11 0 -17.3 0.1 -17.1 -17.5 01/10/2005 03:10:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 46 6 305 305 11 0 11 0 -17.3 0 -17.1 -17.5 01/10/2005 03:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 48 6 305 305 11 0 11 0 -17.4 0 -17.1 -17.5 01/10/2005 03:30:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.8 0.4 0 0.4 0.4 44 6 305 305 11 0 11 0 -17.3 0 -16.9 -17.5 01/10/2005 03:40:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 44 5 305 305 11 0 12 0 -17.4 0 -17.1 -17.5 01/10/2005 03:50:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 45 6 305 305 11 0 11 0 -17.3 0 -16.9 -17.5 01/10/2005 04:00:00 0.4 0 0.4 0.4 7.7 0.2 8.4 7.2 0.4 0 0.4 0.4 41 5 305 305 11 0 11 0 -17.2 0 -16.9 -17.5 01/10/2005 04:10:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 49 6 305 305 11 0 12 0 -17.2 0.1 -16.6 -17.5 01/10/2005 04:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 46 6 305 305 11 0 11 0 -17.4 0.1 -16.9 -17.5 01/10/2005 04:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 47 6 305 305 11 0 11 0 -17.4 0 -16.9 -17.5 01/10/2005 04:40:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 43 6 305 305 11 0 11 0 -17.4 0 -16.9 -17.5 01/10/2005 04:50:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 45 5 305 305 11 0 11 0 -17.5 0.1 -16.9 -17.7 01/10/2005 05:00:00 0.4 0 0.4 0.4 7.7 0.2 8.4 6.8 0.4 0 0.4 0.4 47 6 305 305 11 0 11 0 -17.5 0 -17.3 -17.7 01/10/2005 05:10:00 0.4 0 0.4 0.4 7.6 0.3 8 6.5 0.4 0 0.4 0.4 45 6 305 305 11 0 11 0 -17.4 0.1 -16.9 -17.7 01/10/2005 05:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 42 6 305 305 11 0 11 0 -17.6 0 -17.1 -17.7 01/10/2005 05:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 45 6 305 305 11 0 11 0 -17.6 0.1 -16.9 -17.9 01/10/2005 05:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 40 5 305 305 11 0 11 0 -17.6 0.1 -16.9 -17.9 01/10/2005 05:50:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 47 6 305 305 11 0 11 0 -17.5 0 -16.9 -17.9 01/10/2005 06:00:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.1 0.4 0 0.4 0.4 49 5 305 305 11 0 11 0 -17.6 0.1 -16.9 -17.9 01/10/2005 06:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 51 5 305 305 11 0 11 0 -17.7 0 -17.3 -17.9 01/10/2005 06:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 51 5 305 305 11 0 11 0 -17.8 0.1 -17.3 -18.1 01/10/2005 06:30:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 47 6 305 305 11 0 11 0 -17.7 0.1 -17.3 -18.1 01/10/2005 06:40:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 47 6 305 305 11 0 11 0 -17.8 0.1 -17.3 -18.1 01/10/2005 06:50:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 50 5 305 305 11 0 11 0 -17.8 0.1 -17.3 -18.1 01/10/2005 07:00:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 46 6 305 305 11 0 11 0 -17.8 0 -17.7 -18.1 01/10/2005 07:10:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 46 6 305 305 11 0 11 0 -17.8 0 -17.7 -18.1 01/10/2005 07:20:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 47 7 305 305 11 0 11 0 -17.8 0.1 -17.5 -18.1 01/10/2005 07:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.5 0.4 0 0.4 0.4 47 5 305 305 11 0 11 0 -17.9 0 -17.7 -18.1 01/10/2005 07:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 46 5 305 305 10 0 11 0 -18 0 -17.9 -18.1 01/10/2005 07:50:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 42 6 305 305 10 0 10 0 -18 0 -17.7 -18.1 01/10/2005 08:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 43 6 305 305 10 0 10 0 -18 0 -17.5 -18.1 01/10/2005 08:10:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -18 0 -17.5 -18.1 01/10/2005 08:20:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 47 5 305 305 10 0 10 0 -18.1 0 -17.5 -18.4 01/10/2005 08:30:00 0.4 0 0.4 0.4 7.7 0.2 8.4 6.8 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -18.1 0 -17.7 -18.4 01/10/2005 08:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 45 6 305 305 10 0 10 0 -18.1 0.1 -17.7 -18.4 01/10/2005 08:50:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 47 5 305 305 10 0 10 0 -18.2 0 -17.7 -18.4 01/10/2005 09:00:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 45 5 305 305 10 0 10 0 -18.2 0 -18.1 -18.4 01/10/2005 09:10:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 48 5 305 305 10 0 10 0 -18.3 0 -18.1 -18.4 01/10/2005 09:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 44 6 305 305 10 0 10 0 -18.3 0 -17.9 -18.4 01/10/2005 09:30:00 0.4 0 0.4 0.4 7.7 0.3 8 6.8 0.4 0 0.4 0.4 44 5 305 305 10 0 10 0 -18.3 0.1 -17.9 -18.4 01/10/2005 09:40:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 43 6 305 305 10 0 10 0 -18.4 0.1 -17.9 -18.4 01/10/2005 09:50:00 0.4 0 0.4 0.4 7.6 0.3 8 6.8 0.4 0 0.4 0.4 47 6 305 305 10 0 10 0 -18.2 0.1 -17.9 -18.4 01/10/2005 10:00:00 0.4 0 0.4 0.4 7.6 0.4 8 5.7 0.4 0 0.4 0.4 46 5 305 305 10 0 10 0 -18.3 0 -18.2 -18.4 01/10/2005 10:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 46 5 305 305 10 0 10 0 -18.4 0 -18.1 -18.4 01/10/2005 10:20:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 46 7 305 305 10 0 10 0 -18.3 0 -18.1 -18.4 01/10/2005 10:30:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 45 6 305 305 10 0 10 0 -18.4 0 -18.1 -18.4 01/10/2005 10:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 48 5 305 305 10 0 10 0 -18.5 0 -18.2 -18.4 01/10/2005 10:50:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 43 4 305 305 10 0 10 0 -18.5 0 -18.1 -18.4 01/10/2005 11:00:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 44 5 305 305 10 0 10 0 -18.5 0 -18.1 -18.6 01/10/2005 11:10:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 44 6 305 305 10 0 10 0 -18.5 0.1 -18.1 -18.4 01/10/2005 11:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 44 5 305 305 10 0 10 0 -18.5 0 -18.1 -18.6 01/10/2005 11:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 49 7 305 305 10 0 9 0 -18.5 0 -18.1 -18.6 01/10/2005 11:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 51 5 305 305 10 0 10 0 -18.6 0 -18.4 -18.8 01/10/2005 11:50:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 49 5 305 305 9 0 9 0 -18.7 0 -18.4 -18.8 01/10/2005 12:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 48 6 305 305 9 0 9 0 -18.7 0 -18.2 -18.8 01/10/2005 12:10:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -18.8 0 -18.2 -19 01/10/2005 12:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -18.8 0 -18.2 -19 01/10/2005 12:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -18.9 0 -18.4 -19 01/10/2005 12:40:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 47 6 305 305 9 0 9 0 -18.8 0 -18.4 -19 01/10/2005 12:50:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 47 6 305 305 9 0 9 0 -18.9 0.1 -18.2 -19 01/10/2005 13:00:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 52 5 305 305 9 0 9 0 -19.1 0 -19 -19.2 01/10/2005 13:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 50 5 305 305 9 0 9 0 -19.1 0 -18.6 -19.2 01/10/2005 13:20:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 50 5 305 305 9 0 9 0 -19.2 0 -18.8 -19.3 01/10/2005 13:30:00 0.4 0 0.4 0.4 7.7 0.3 8 6.8 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -19.2 0 -18.8 -19.3 01/10/2005 13:40:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 52 5 305 305 9 0 9 0 -19.2 0 -18.8 -19.3 01/10/2005 13:50:00 0.4 0 0.4 0.4 7.6 0.3 8.4 6.5 0.4 0 0.4 0.4 47 6 305 305 9 0 9 0 -19.2 0 -18.8 -19.3 01/10/2005 14:00:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 46 5 305 305 9 0 9 0 -19.2 0.1 -18.6 -19.3 01/10/2005 14:10:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.1 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -19.1 0 -18.6 -19.3 01/10/2005 14:20:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -19.2 0.1 -18.8 -19.5 01/10/2005 14:30:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 52 5 305 305 9 0 9 0 -19.2 0 -18.8 -19.5 01/10/2005 14:40:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 44 4 305 305 9 0 9 0 -19.2 0 -18.8 -19.3 01/10/2005 14:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -19.2 0 -18.8 -19.3 01/10/2005 15:00:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 48 6 305 305 9 0 9 0 -19.2 0.1 -18.8 -19.5 01/10/2005 15:10:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 51 7 305 305 9 0 9 0 -19.2 0 -18.8 -19.5 01/10/2005 15:20:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 54 5 305 305 9 0 9 0 -19.2 0 -18.8 -19.3 01/10/2005 15:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 49 5 305 305 9 0 9 0 -19.2 0 -19 -19.3 01/10/2005 15:40:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 51 5 305 305 9 0 9 0 -19.2 0 -18.8 -19.3 01/10/2005 15:50:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 48 6 305 305 9 0 9 0 -19.2 0 -18.8 -19.5 01/10/2005 16:00:00 0.4 0 0.4 0.4 7.7 0.3 8 6.1 0.4 0 0.4 0.4 52 6 305 305 9 0 9 0 -19.1 0 -18.6 -19.3 01/10/2005 16:10:00 0.4 0 0.4 0.4 7.5 0.4 8 6.1 0.4 0 0.4 0.4 51 6 305 305 9 0 9 0 -19.2 0 -19 -19.3 01/10/2005 16:20:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.1 0.4 0 0.4 0.4 46 5 305 305 9 0 9 0 -19.2 0 -19 -19.3 01/10/2005 16:30:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 45 5 305 305 9 0 9 0 -19.2 0 -19 -19.3 01/10/2005 16:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 48 6 305 305 9 0 9 0 -19.2 0 -19 -19.5 01/10/2005 16:50:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 51 6 305 305 9 0 9 0 -19.2 0 -19 -19.3 01/10/2005 17:00:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 52 5 305 305 9 0 9 0 -19.2 0 -19 -19.3 01/10/2005 17:10:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 52 5 305 305 9 0 9 0 -19.2 0 -19 -19.3 01/10/2005 17:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 46 6 305 305 9 0 9 0 -19.2 0 -19 -19.3 01/10/2005 17:30:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 46 6 305 305 9 0 9 0 -19.2 0 -19 -19.3 01/10/2005 17:40:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -19.2 0 -19 -19.5 01/10/2005 17:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 48 6 305 305 9 0 8 0 -19.2 0 -19 -19.5 01/10/2005 18:00:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 45 5 305 305 9 0 8 0 -19.2 0 -19 -19.3 01/10/2005 18:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 47 6 305 305 9 0 9 0 -19.2 0 -19 -19.5 01/10/2005 18:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.6 0.4 0 0.4 0.4 46 5 305 305 8 0 9 0 -19.2 0 -19 -19.5 01/10/2005 18:30:00 0.4 0 0.4 0.4 7.6 0.4 8 6.1 0.4 0 0.4 0.4 50 6 305 305 9 0 8 0 -19.2 0.1 -18.8 -19.5 01/10/2005 18:40:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 50 5 305 305 8 0 8 0 -19.3 0 -19 -19.5 01/10/2005 18:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 48 5 305 305 8 0 8 0 -19.3 0.1 -19 -19.5 01/10/2005 19:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 52 4 305 305 8 0 8 0 -19.4 0 -19 -19.5 01/10/2005 19:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 49 5 305 305 8 0 8 0 -19.4 0.1 -19 -19.5 01/10/2005 19:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.5 0.4 0 0.4 0.4 50 6 305 305 8 0 8 0 -19.5 0.1 -19 -19.5 01/10/2005 19:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 48 4 305 305 8 0 8 0 -19.5 0.1 -19 -19.5 01/10/2005 19:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 46 5 305 305 8 0 8 0 -19.4 0.1 -19 -19.5 01/10/2005 19:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 51 5 305 305 8 0 8 0 -19.4 0.1 -19 -19.5 01/10/2005 20:00:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 48 4 305 305 8 0 8 0 -19.5 0 -19 -19.5 01/10/2005 20:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 51 5 305 305 8 0 8 0 -19.5 0 -19 -19.5 01/10/2005 20:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 51 6 305 305 8 0 8 0 -19.5 0 -19 -19.5 01/10/2005 20:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 49 4 305 305 8 0 8 0 -19.4 0 -19 -19.5 01/10/2005 20:40:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 49 4 305 305 8 0 8 0 -19.5 0.1 -19 -19.5 01/10/2005 20:50:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 49 4 305 305 8 0 8 0 -19.5 0 -19 -19.5 01/10/2005 21:00:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 49 4 305 305 8 0 8 0 -19.4 0 -19 -19.5 01/10/2005 21:10:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 54 6 305 305 8 0 8 0 -19.4 0 -19.2 -19.5 01/10/2005 21:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 51 6 305 305 8 0 8 0 -19.4 0 -19.2 -19.5 01/10/2005 21:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 53 6 305 305 8 0 8 0 -19.5 0 -19.3 -19.5 01/10/2005 21:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.5 0.4 0 0.4 0.4 50 5 305 305 8 0 8 0 -19.5 0 -19.2 -19.5 01/10/2005 21:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 49 5 305 305 8 0 8 0 -19.5 0 -19 -19.5 01/10/2005 22:00:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 52 5 305 305 8 0 8 0 -19.5 0 -19.2 -19.5 01/10/2005 22:10:00 0.4 0 0.4 0.4 7.8 0.2 8 6.5 0.4 0 0.4 0.4 52 5 305 305 8 0 8 0 -19.5 0 -19.2 -19.5 01/10/2005 22:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 51 4 305 305 8 0 8 0 -19.6 0 -19.2 -19.7 01/10/2005 22:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 48 4 305 305 8 0 8 0 -19.6 0 -19.3 -19.7 01/10/2005 22:40:00 0.4 0 0.4 0.4 7.8 0.2 8 6.5 0.4 0 0.4 0.4 48 5 305 305 8 0 8 0 -19.5 0.1 -19 -19.5 01/10/2005 22:50:00 0.4 0 0.4 0.4 7.8 0.2 8 6.5 0.4 0 0.4 0.4 50 5 305 305 8 0 8 0 -19.5 0 -19.3 -19.5 01/10/2005 23:00:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 46 4 305 305 8 0 8 0 -19.5 0.1 -19 -19.5 01/10/2005 23:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 47 4 305 305 8 0 8 0 -19.5 0.1 -19 -19.5 01/10/2005 23:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 46 5 305 305 8 0 8 0 -19.5 0.1 -19 -19.5 01/10/2005 23:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 49 4 305 305 8 0 8 0 -19.5 0.1 -19 -19.5 01/10/2005 23:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 47 5 305 305 8 0 8 0 -19.4 0.1 -19 -19.5 01/10/2005 23:50:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 47 5 305 305 8 0 8 0 -19.4 0.1 -19 -19.5 01/11/2005 00:00:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 49 5 305 305 8 0 8 0 -19.5 0.1 -19 -19.5 01/11/2005 00:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 49 6 305 305 8 0 8 0 -19.5 0 -19 -19.5 01/11/2005 00:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 49 5 305 305 8 0 8 0 -19.5 0 -19 -19.5 01/11/2005 00:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 49 5 305 305 8 0 8 0 -19.5 0 -19.3 -19.5 01/11/2005 00:40:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 51 6 305 305 8 0 8 0 -19.5 0.1 -19 -19.5 01/11/2005 00:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 50 5 305 305 8 0 8 0 -19.5 0 -19.3 -19.5 01/11/2005 01:00:00 0.4 0 0.4 0.4 7.6 0.4 8 6.1 0.4 0 0.4 0.4 48 7 305 305 8 0 8 0 -19.4 0 -19 -19.5 01/11/2005 01:10:00 0.4 0 0.4 0.4 7.7 0.4 8 6.1 0.4 0 0.4 0.4 52 5 305 305 8 0 8 0 -19.5 0 -19 -19.5 01/11/2005 01:20:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 49 6 305 305 8 0 8 0 -19.5 0 -19 -19.5 01/11/2005 01:30:00 0.4 0 0.4 0.4 7.7 0.4 8 6.1 0.4 0 0.4 0.4 50 6 305 305 8 0 8 0 -19.4 0 -19.3 -19.5 01/11/2005 01:40:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 51 5 305 305 8 0 8 0 -19.4 0 -19.2 -19.5 01/11/2005 01:50:00 0.4 0 0.7 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 50 6 59 305 8 0 8 0 -19.3 0 -19 -19.5 01/11/2005 02:00:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 50 5 305 305 8 0 8 0 -19.2 0 -19 -19.5 01/11/2005 02:10:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 52 5 305 305 8 0 8 0 -19.3 0 -19 -19.5 01/11/2005 02:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 51 5 305 305 8 0 8 0 -19.2 0 -19 -19.5 01/11/2005 02:30:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 52 5 305 305 8 0 8 0 -19.2 0 -19 -19.3 01/11/2005 02:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.5 0.4 0 0.4 0.4 52 6 305 305 8 0 8 0 -19.2 0 -18.6 -19.3 01/11/2005 02:50:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 55 6 305 305 8 0 8 0 -19.1 0 -19 -19.2 01/11/2005 03:00:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 52 5 305 305 8 0 8 0 -19.1 0 -18.6 -19.2 01/11/2005 03:10:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 51 5 305 305 8 0 8 0 -19.1 0 -19 -19.2 01/11/2005 03:20:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 53 6 305 305 8 0 8 0 -19.1 0 -18.4 -19.2 01/11/2005 03:30:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 53 5 305 305 8 0 8 0 -19 0 -18.8 -19 01/11/2005 03:40:00 0.4 0 0.4 0.4 7.6 0.4 8 6.5 0.4 0 0.4 0.4 50 6 305 305 8 0 8 0 -19 0 -18.8 -19 01/11/2005 03:50:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 52 6 305 305 9 0 8 0 -19 0 -18.8 -19 01/11/2005 04:00:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 47 5 305 305 8 0 8 0 -19 0.1 -18.4 -19 01/11/2005 04:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 49 5 305 305 9 0 8 0 -18.9 0 -18.4 -19 01/11/2005 04:20:00 0.4 0 0.4 0.4 7.8 0.2 8 6.5 0.4 0 0.4 0.4 49 6 305 305 9 0 8 0 -18.8 0 -18.4 -19 01/11/2005 04:30:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 49 6 305 305 9 0 9 0 -18.8 0 -18.6 -19 01/11/2005 04:40:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 48 6 305 305 9 0 8 0 -18.9 0.1 -18.4 -19 01/11/2005 04:50:00 0.4 0 0.4 0.4 7.7 0.3 8 6.8 0.4 0 0.4 0.4 52 5 305 305 9 0 9 0 -18.8 0 -18.6 -19 01/11/2005 05:00:00 0.4 0 0.4 0.4 7.6 0.3 8 6.5 0.4 0 0.4 0.4 49 6 305 305 9 0 9 0 -18.8 0 -18.4 -19 01/11/2005 05:10:00 0.4 0 0.4 0.4 7.4 0.4 8 6.1 0.4 0 0.4 0.4 51 7 305 305 9 0 9 0 -18.8 0 -18.6 -19 01/11/2005 05:20:00 0.4 0 0.4 0.4 7.4 0.5 8 6.1 0.4 0 0.4 0.4 53 6 305 305 9 0 9 0 -18.7 0 -18.4 -19 01/11/2005 05:30:00 0.4 0 0.4 0.4 7.6 0.4 8 6.5 0.4 0 0.4 0.4 51 6 305 305 9 0 9 0 -18.7 0 -18.4 -19 01/11/2005 05:40:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 49 6 305 305 9 0 9 0 -18.7 0 -18.4 -18.8 01/11/2005 05:50:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -18.7 0 -18.4 -18.8 01/11/2005 06:00:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 52 5 305 305 9 0 9 0 -18.6 0 -18.4 -18.8 01/11/2005 06:10:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -18.6 0 -18.4 -18.6 01/11/2005 06:20:00 0.4 0 0.4 0.4 7.8 0.3 8 6.8 0.4 0 0.4 0.4 45 5 305 305 9 0 9 0 -18.5 0 -18.2 -18.6 01/11/2005 06:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 48 6 305 305 9 0 9 0 -18.5 0 -18.2 -18.6 01/11/2005 06:40:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 48 6 305 305 9 0 9 0 -18.5 0 -18.2 -18.4 01/11/2005 06:50:00 0.4 0 0.4 0.4 7.8 0.3 8 6.8 0.4 0 0.4 0.4 46 6 305 305 9 0 9 0 -18.4 0 -18.2 -18.4 01/11/2005 07:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 48 5 305 305 9 0 10 0 -18.4 0 -18.2 -18.4 01/11/2005 07:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 50 4 305 305 9 0 9 0 -18.4 0 -18.2 -18.4 01/11/2005 07:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 50 5 305 305 9 0 9 0 -18.4 0 -18.2 -18.4 01/11/2005 07:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 50 4 305 305 9 0 9 0 -18.4 0 -18.1 -18.4 01/11/2005 07:40:00 0.4 0 0.4 0.4 7.6 0.3 8 6.8 0.4 0 0.4 0.4 54 6 305 305 9 0 9 0 -18.3 0 -18.1 -18.4 01/11/2005 07:50:00 0.4 0 0.4 0.4 7.7 0.3 8 6.1 0.4 0 0.4 0.4 54 5 305 305 9 0 9 0 -18.3 0 -18.1 -18.4 01/11/2005 08:00:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 52 5 305 305 9 0 9 0 -18.3 0 -17.9 -18.4 01/11/2005 08:10:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 56 5 305 305 9 0 9 0 -18.3 0 -17.9 -18.4 01/11/2005 08:20:00 0.4 0 0.4 0.4 7.6 0.4 8.4 6.1 0.4 0 0.4 0.4 55 5 305 305 9 0 9 0 -18.2 0 -17.7 -18.4 01/11/2005 08:30:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 53 4 305 305 9 0 9 0 -18.3 0 -18.1 -18.4 01/11/2005 08:40:00 0.4 0 0.4 0.4 7.6 0.3 8 6.5 0.4 0 0.4 0.4 51 6 305 305 9 0 9 0 -18.1 0 -17.7 -18.4 01/11/2005 08:50:00 0.4 0 0.4 0.4 7.8 0.3 8 6.8 0.4 0 0.4 0.4 47 6 305 305 9 0 9 0 -18.2 0 -18.1 -18.4 01/11/2005 09:00:00 0.4 0 0.4 0.4 7.6 0.3 8 6.1 0.4 0 0.4 0.4 49 5 305 305 9 0 10 0 -18.1 0 -18.1 -18.4 01/11/2005 09:10:00 0.4 0 0.4 0.4 7.7 0.3 8 6.8 0.4 0 0.4 0.4 52 5 305 305 10 0 9 0 -18.1 0 -18.1 -18.2 01/11/2005 09:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 48 5 305 305 10 0 9 0 -18 0 -17.5 -18.1 01/11/2005 09:30:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 52 5 305 305 10 0 10 0 -18 0 -17.9 -18.1 01/11/2005 09:40:00 0.4 0 0.4 0.4 7.8 0.2 8 6.5 0.4 0 0.4 0.4 52 5 305 305 10 0 9 0 -18 0 -17.9 -18.1 01/11/2005 09:50:00 0.4 0 0.4 0.4 7.8 0.3 8 6.5 0.4 0 0.4 0.4 53 5 305 305 10 0 9 0 -18 0 -17.7 -18.1 01/11/2005 10:00:00 0.4 0 0.4 0.4 7.6 0.4 8 6.1 0.4 0 0.4 0.4 54 5 305 305 10 0 9 0 -17.9 0 -17.5 -18.1 01/11/2005 10:10:00 0.4 0 0.4 0.4 7.8 0.2 8 6.5 0.4 0 0.4 0.4 50 4 305 305 10 0 9 0 -17.9 0 -17.7 -18.1 01/11/2005 10:20:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 51 5 305 305 10 0 9 0 -17.8 0 -17.7 -18.1 01/11/2005 10:30:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 49 5 305 305 10 0 10 0 -17.8 0 -17.5 -18.1 01/11/2005 10:40:00 0.4 0 0.4 0.4 7.6 0.3 8 6.5 0.4 0 0.4 0.4 48 5 305 305 10 0 10 0 -17.8 0 -17.5 -18.1 01/11/2005 10:50:00 0.4 0 0.4 0.4 7.6 0.3 8 6.8 0.4 0 0.4 0.4 51 5 305 305 10 0 10 0 -17.6 0 -17.5 -17.9 01/11/2005 11:00:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 50 5 305 305 10 0 10 0 -17.6 0 -17.3 -17.9 01/11/2005 11:10:00 0.4 0 0.4 0.4 7.6 0.3 8 6.5 0.4 0 0.4 0.4 51 4 305 305 10 0 10 0 -17.5 0 -17.5 -17.7 01/11/2005 11:20:00 0.4 0 0.4 0.4 7.6 0.3 8 6.1 0.4 0 0.4 0.4 50 5 305 305 11 0 11 0 -17.5 0 -17.1 -18.1 01/11/2005 11:30:00 0.4 0 0.4 0.4 7.5 0.4 8 6.5 0.4 0 0.4 0.4 49 5 305 305 11 0 11 0 -17.4 0 -17.1 -17.5 01/11/2005 11:40:00 0.4 0 0.4 0.4 7.6 0.3 8 6.5 0.4 0 0.4 0.4 46 4 305 305 11 0 11 0 -17.4 0 -17.3 -17.5 01/11/2005 11:50:00 0.4 0 0.4 0.4 7.3 0.4 8 5.7 0.4 0 0.4 0.4 44 6 305 305 11 0 11 0 -17.3 0 -17.1 -17.5 01/11/2005 12:00:00 0.4 0 0.4 0.4 7.3 0.4 8 5.7 0.4 0 0.4 0.4 43 6 305 305 11 0 11 0 -17.3 0 -17.1 -17.5 01/11/2005 12:10:00 0.4 0 0.4 0.4 7.2 0.5 8 5.7 0.4 0 0.4 0.4 48 5 305 305 11 0 11 0 -17.2 0 -16.9 -17.3 01/11/2005 12:20:00 0.4 0 0.4 0.4 7.4 0.4 8 6.1 0.4 0 0.4 0.4 46 5 305 305 11 0 11 0 -17.1 0 -16.9 -17.3 01/11/2005 12:30:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 48 6 305 305 11 0 11 0 -17.2 0 -16.9 -17.3 01/11/2005 12:40:00 0.4 0 0.4 0.4 7.6 0.3 8 6.5 0.4 0 0.4 0.4 52 5 305 305 11 0 11 0 -17.1 0 -16.9 -17.3 01/11/2005 12:50:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 47 4 305 305 11 0 11 0 -17.1 0 -16.9 -17.3 01/11/2005 13:00:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 48 4 305 305 11 0 11 0 -17.1 0 -16.9 -17.3 01/11/2005 13:10:00 0.4 0 0.4 0.4 7.8 0.3 8 6.5 0.4 0 0.4 0.4 50 5 305 305 11 0 11 0 -17.1 0 -16.9 -17.3 01/11/2005 13:20:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 46 5 305 305 11 0 11 0 -17.1 0 -16.9 -17.3 01/11/2005 13:30:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 52 5 305 305 11 0 11 0 -17 0 -16.7 -17.5 01/11/2005 13:40:00 0.4 0 0.4 0.4 7.8 0.3 8 6.5 0.4 0 0.4 0.4 48 5 305 305 11 0 11 0 -17 0.1 -16.9 -17.5 01/11/2005 13:50:00 0.4 0 0.4 0.4 7.7 0.4 8 6.5 0.4 0 0.4 0.4 50 5 305 305 11 0 11 0 -17.1 0.1 -16.9 -17.5 01/11/2005 14:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 49 5 305 305 11 0 11 0 -17 0 -16.9 -17.1 01/11/2005 14:10:00 0.4 0 0.4 0.4 7.8 0.3 8 6.5 0.4 0 0.4 0.4 45 5 305 305 11 0 11 0 -17.1 0 -16.9 -17.3 01/11/2005 14:20:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 47 5 305 305 11 0 11 0 -17 0 -16.9 -17.1 01/11/2005 14:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 49 4 305 305 11 0 11 0 -17.1 0 -16.9 -17.1 01/11/2005 14:40:00 0.4 0 0.4 0.4 7.7 0.4 8 6.1 0.4 0 0.4 0.4 48 6 305 305 11 0 11 0 -17 0 -16.9 -17.1 01/11/2005 14:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 50 5 305 305 11 0 11 0 -17.1 0 -16.9 -17.1 01/11/2005 15:00:00 0.4 0 0.4 0.4 7.8 0.3 8 6.5 0.4 0 0.4 0.4 51 6 305 305 11 0 11 0 -17 0 -16.9 -17.1 01/11/2005 15:10:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 50 5 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 15:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 47 5 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 15:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 49 5 305 305 11 0 11 0 -16.9 0 -16.9 -17.1 01/11/2005 15:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 47 5 305 305 11 0 11 0 -16.9 0 -16.9 -17.1 01/11/2005 15:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 46 5 305 305 11 0 11 0 -16.9 0 -16.9 -17.1 01/11/2005 16:00:00 0.4 0 0.4 0.4 7.8 0.3 8 6.8 0.4 0 0.4 0.4 49 5 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 16:10:00 0.4 0 0.4 0.4 7.6 0.4 8 6.1 0.4 0 0.4 0.4 47 6 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 16:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 49 5 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 16:30:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 47 5 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 16:40:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 50 5 305 305 11 0 11 0 -16.9 0 -16.9 -17.1 01/11/2005 16:50:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 49 6 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 17:00:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.5 0.4 0 0.4 0.4 50 6 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 17:10:00 0.4 0 0.4 0.4 7.7 0.4 8 6.1 0.4 0 0.4 0.4 51 5 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 17:20:00 0.4 0 0.4 0.4 7.7 0.4 8 6.1 0.4 0 0.4 0.4 52 6 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 17:30:00 0.4 0 0.4 0.4 7.7 0.4 8 6.5 0.4 0 0.4 0.4 48 5 305 305 11 0 11 0 -16.9 0 -16.6 -16.9 01/11/2005 17:40:00 0.4 0 0.4 0.4 7.6 0.4 8 6.5 0.4 0 0.4 0.4 49 6 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 17:50:00 0.4 0 0.4 0.4 7.6 0.4 8 6.1 0.4 0 0.4 0.4 53 5 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 18:00:00 0.4 0 0.4 0.4 7.6 0.5 8.4 5.3 0.4 0 0.4 0.4 51 6 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 18:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 51 5 305 305 11 0 11 0 -17 0 -16.9 -17.1 01/11/2005 18:20:00 0.4 0 0.4 0.4 7.8 0.4 8.4 6.1 0.4 0 0.4 0.4 53 4 305 305 11 0 11 0 -17 0 -16.9 -17.1 01/11/2005 18:30:00 0.4 0 0.4 0.4 7.7 0.4 8 6.1 0.4 0 0.4 0.4 53 5 305 305 11 0 11 0 -17 0 -16.9 -17.3 01/11/2005 18:40:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 54 5 305 305 11 0 11 0 -17 0 -16.9 -17.1 01/11/2005 18:50:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.5 0.4 0 0.4 0.4 54 5 305 305 11 0 11 0 -17 0 -16.9 -16.9 01/11/2005 19:00:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.5 0.4 0 0.4 0.4 56 6 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 19:10:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.5 0.4 0 0.4 0.4 53 4 305 305 11 0 11 0 -16.9 0 -16.9 -16.9 01/11/2005 19:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 56 5 305 305 11 0 11 0 -16.9 0 -16.7 -16.9 01/11/2005 19:30:00 0.4 0 0.4 0.4 7.7 0.4 8 6.5 0.4 0 0.4 0.4 54 4 305 305 11 0 11 0 -16.9 0 -16.6 -16.9 01/11/2005 19:40:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 51 5 305 305 11 0 11 0 -16.7 0.1 -16.6 -16.9 01/11/2005 19:50:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 52 4 305 305 11 0 11 0 -16.7 0 -16.6 -16.9 01/11/2005 20:00:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 52 4 305 305 11 0 11 0 -16.7 0 -16.2 -16.9 01/11/2005 20:10:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.5 0.4 0 0.4 0.4 53 4 305 305 11 0 11 0 -16.7 0 -16.6 -16.9 01/11/2005 20:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 51 4 305 305 11 0 11 0 -16.7 0 -16.6 -16.9 01/11/2005 20:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 52 5 305 305 11 0 11 0 -16.7 0 -16.6 -16.9 01/11/2005 20:40:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 52 5 305 305 11 0 11 0 -16.7 0 -16.6 -16.9 01/11/2005 20:50:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 51 5 305 305 11 0 11 0 -16.7 0.1 -16.6 -16.9 01/11/2005 21:00:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 51 5 305 305 11 0 11 0 -16.7 0 -16.6 -16.9 01/11/2005 21:10:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 53 5 305 305 11 0 11 0 -16.5 0 -16.4 -16.6 01/11/2005 21:20:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.5 0.4 0 0.4 0.4 54 5 305 305 11 0 11 0 -16.5 0 -16.4 -16.6 01/11/2005 21:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 50 4 305 305 11 0 11 0 -16.4 0 -16 -16.6 01/11/2005 21:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.5 0.4 0 0.4 0.4 50 4 305 305 11 0 11 0 -16.5 0 -16.4 -16.6 01/11/2005 21:50:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 51 4 305 305 11 0 12 0 -16.5 0 -16.4 -16.6 01/11/2005 22:00:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 51 4 305 305 11 0 11 0 -16.4 0 -16.4 -16.6 01/11/2005 22:10:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 50 5 305 305 11 0 11 0 -16.4 0 -16.4 -16.6 01/11/2005 22:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 52 5 305 305 11 0 11 0 -16.5 0 -16.4 -16.6 01/11/2005 22:30:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.5 0.4 0 0.4 0.4 53 5 305 305 11 0 11 0 -16.4 0 -16.4 -16.6 01/11/2005 22:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 49 5 305 305 11 0 11 0 -16.4 0 -16.4 -16.6 01/11/2005 22:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 50 4 305 305 11 0 11 0 -16.5 0 -16.4 -16.6 01/11/2005 23:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 52 5 305 305 11 0 11 0 -16.5 0 -16.4 -16.6 01/11/2005 23:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 52 5 305 305 11 0 11 0 -16.6 0 -16.4 -16.6 01/11/2005 23:20:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 51 3 305 305 11 0 11 0 -16.7 0 -16.6 -16.9 01/11/2005 23:30:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 54 4 305 305 11 0 11 0 -16.6 0 -16.4 -16.7 01/11/2005 23:40:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 55 4 305 305 11 0 11 0 -16.6 0 -16.6 -16.9 01/11/2005 23:50:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 52 5 305 305 11 0 11 0 -16.7 0 -16.6 -16.9 01/12/2005 00:00:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 52 4 305 305 11 0 11 0 -16.6 0 -16 -16.9 01/12/2005 00:10:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 52 4 305 305 11 0 11 0 -16.6 0 -16 -16.9 01/12/2005 00:20:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 51 3 305 305 11 0 11 0 -16.6 0 -16 -16.7 01/12/2005 00:30:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 53 5 305 305 11 0 11 0 -16.7 0.1 -16 -16.9 01/12/2005 00:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 54 5 305 305 11 0 11 0 -16.7 0.1 -16.2 -16.9 01/12/2005 00:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 49 4 305 305 11 0 11 0 -16.8 0.1 -16.2 -16.9 01/12/2005 01:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 49 5 305 305 11 0 11 0 -16.8 0.1 -16.2 -16.9 01/12/2005 01:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 47 4 305 305 11 0 11 0 -16.8 0.1 -16.6 -16.9 01/12/2005 01:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 45 5 305 305 11 0 11 0 -16.8 0.1 -16.2 -16.9 01/12/2005 01:30:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 3 305 305 11 0 11 0 -16.9 0 -16.4 -16.9 01/12/2005 01:40:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 44 4 305 305 11 0 11 0 -16.8 0.1 -16.4 -16.9 01/12/2005 01:50:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 47 5 305 305 11 0 11 0 -16.8 0 -16.2 -16.9 01/12/2005 02:00:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 48 6 305 305 11 0 11 0 -16.9 0 -16.2 -16.9 01/12/2005 02:10:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 47 4 305 305 11 0 11 0 -16.9 0 -16.4 -16.9 01/12/2005 02:20:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 45 5 305 305 11 0 11 0 -16.9 0 -16.4 -16.9 01/12/2005 02:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 48 4 305 305 10 0 11 0 -17 0 -16.6 -17.1 01/12/2005 02:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 47 4 305 305 10 0 11 0 -17 0 -16.9 -17.1 01/12/2005 02:50:00 0.4 0 0.4 0.4 7.6 0.4 8 6.1 0.4 0 0.4 0.4 47 6 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/12/2005 03:00:00 0.4 0 0.4 0.4 7.8 0.3 8 6.8 0.4 0 0.4 0.4 46 5 305 305 10 0 10 0 -17 0 -16.6 -17.1 01/12/2005 03:10:00 0.4 0 0.4 0.4 7.6 0.4 8.4 6.1 0.4 0 0.4 0.4 42 5 305 305 10 0 10 0 -17 0 -16.6 -17.1 01/12/2005 03:20:00 0.4 0 0.4 0.4 7.8 0.3 8 6.5 0.4 0 0.4 0.4 45 6 305 305 10 0 10 0 -17 0 -16.9 -17.1 01/12/2005 03:30:00 0.4 0 0.4 0.4 7.7 0.4 8 6.1 0.4 0 0.4 0.4 47 5 305 305 10 0 10 0 -17 0 -16.9 -17.1 01/12/2005 03:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 44 5 305 305 10 0 10 0 -17 0 -16.6 -17.1 01/12/2005 03:50:00 0.4 0 0.4 0.4 7.7 0.4 8 6.1 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -16.9 0 -16.9 -17.1 01/12/2005 04:00:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 41 5 305 305 10 0 10 0 -16.9 0 -16.4 -16.9 01/12/2005 04:10:00 0.4 0 0.4 0.4 7.5 0.4 8.4 6.5 0.4 0 0.4 0.4 45 7 305 305 10 0 10 0 -16.9 0 -16.6 -17.1 01/12/2005 04:20:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.1 0.4 0 0.4 0.4 48 5 305 305 10 0 10 0 -17 0 -16.6 -17.1 01/12/2005 04:30:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 47 6 305 305 10 0 10 0 -17.1 0 -16.6 -17.3 01/12/2005 04:40:00 0.4 0 0.4 0.4 7.8 0.3 8 6.5 0.4 0 0.4 0.4 47 3 305 305 10 0 10 0 -17.1 0 -16.6 -17.3 01/12/2005 04:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 47 4 305 305 10 0 10 0 -17.2 0 -16.9 -17.3 01/12/2005 05:00:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.5 0.4 0 0.4 0.4 47 5 305 305 10 0 10 0 -17.3 0 -17.1 -17.3 01/12/2005 05:10:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 46 5 305 305 10 0 10 0 -17.3 0 -16.9 -17.5 01/12/2005 05:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -17.3 0 -17.1 -17.5 01/12/2005 05:30:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 46 5 305 305 10 0 10 0 -17.4 0 -17.1 -17.5 01/12/2005 05:40:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.1 0.4 0 0.4 0.4 44 5 305 305 10 0 9 0 -17.4 0 -17.3 -17.5 01/12/2005 05:50:00 0.4 0 0.4 0.4 7.7 0.4 8 6.1 0.4 0 0.4 0.4 43 5 305 305 10 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 06:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.5 0.4 0 0.4 0.4 43 5 305 305 10 0 9 0 -17.4 0 -16.9 -17.5 01/12/2005 06:10:00 0.4 0 0.4 0.4 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 42 5 305 305 10 0 10 0 -17.5 0 -16.9 -17.5 01/12/2005 06:20:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 43 4 305 305 10 0 9 0 -17.5 0 -17.5 -17.7 01/12/2005 06:30:00 0.4 0 0.4 0.4 7.4 0.5 8.4 6.1 0.4 0 0.4 0.4 40 6 305 305 9 0 9 0 -17.5 0 -17.3 -17.7 01/12/2005 06:40:00 0.4 0 0.4 0.4 7.5 0.5 8.4 5.7 0.4 0 0.4 0.4 40 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/12/2005 06:50:00 0.4 0 0.4 0.4 7.6 0.4 8.4 6.1 0.4 0 0.4 0.4 41 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/12/2005 07:00:00 0.4 0 0.4 0.4 7.8 0.4 8.4 6.5 0.4 0 0.4 0.4 41 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.9 01/12/2005 07:10:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.1 0.4 0 0.4 0.4 40 5 305 305 9 0 9 0 -17.6 0 -17.3 -17.7 01/12/2005 07:20:00 0.4 0 0.4 0.4 7.8 0.4 8.4 6.1 0.4 0 0.4 0.4 41 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/12/2005 07:30:00 0.4 0 0.4 0.4 7.5 0.5 8.4 5.7 0.4 0 0.4 0.4 43 6 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/12/2005 07:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 40 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/12/2005 07:50:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.1 0.4 0 0.4 0.4 43 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.9 01/12/2005 08:00:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 39 5 305 305 9 0 9 0 -17.7 0 -17.1 -17.9 01/12/2005 08:10:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 38 5 305 305 9 0 9 0 -17.7 0 -17.3 -17.9 01/12/2005 08:20:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 41 5 305 305 9 0 9 0 -17.7 0 -17.3 -17.9 01/12/2005 08:30:00 0.4 0 0.4 0.4 7.7 0.4 8.4 6.1 0.4 0 0.4 0.4 40 5 305 305 9 0 9 0 -17.7 0 -17.3 -17.9 01/12/2005 08:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 40 5 305 305 9 0 9 0 -17.7 0 -17.1 -17.9 01/12/2005 08:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 43 4 305 305 9 0 9 0 -17.7 0 -17.3 -17.9 01/12/2005 09:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 40 4 305 305 9 0 9 0 -17.7 0 -17.1 -17.9 01/12/2005 09:10:00 0.4 0 0.4 0.4 7.6 0.4 8.4 6.5 0.4 0 0.4 0.4 41 6 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/12/2005 09:20:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 39 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/12/2005 09:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 43 4 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/12/2005 09:40:00 0.4 0 0.4 0.4 7.5 0.5 8.4 6.1 0.4 0 0.4 0.4 41 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/12/2005 09:50:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 43 6 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/12/2005 10:00:00 0.4 0 0.4 0.4 7.8 0.4 8.4 6.1 0.4 0 0.4 0.4 46 5 305 305 9 0 9 0 -17.7 0 -17.3 -17.9 01/12/2005 10:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 42 5 305 305 9 0 9 0 -17.7 0 -17.3 -17.9 01/12/2005 10:20:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.7 0 -17.3 -17.9 01/12/2005 10:30:00 0.4 0 0.4 0.4 7.8 0.4 8.4 6.5 0.4 0 0.4 0.4 44 5 305 305 9 0 9 0 -17.8 0 -17.3 -17.9 01/12/2005 10:40:00 0.4 0 0.4 0.4 7.9 0.3 8.4 6.8 0.4 0 0.4 0.4 45 4 305 305 9 0 9 0 -17.8 0 -17.3 -17.9 01/12/2005 10:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 44 4 305 305 9 0 9 0 -17.8 0 -17.5 -18.1 01/12/2005 11:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 46 4 305 305 9 0 9 0 -17.8 0 -17.5 -17.9 01/12/2005 11:10:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 43 5 305 305 9 0 9 0 -17.8 0 -17.7 -18.1 01/12/2005 11:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 42 4 305 305 9 0 9 0 -17.8 0 -17.7 -18.1 01/12/2005 11:30:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 43 6 305 305 9 0 9 0 -17.9 0 -17.7 -18.1 01/12/2005 11:40:00 0.4 0 0.4 0.4 7.9 0.3 8.4 6.5 0.4 0 0.4 0.4 42 4 305 305 9 0 9 0 -17.8 0 -17.7 -18.1 01/12/2005 11:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 43 4 305 305 9 0 9 0 -17.8 0 -17.7 -18.1 01/12/2005 12:00:00 0.4 0 0.4 0.4 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 41 5 305 305 9 0 9 0 -17.8 0 -17.5 -18.1 01/12/2005 12:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 42 4 305 305 9 0 9 0 -17.8 0 -17.7 -18.1 01/12/2005 12:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 43 5 305 305 9 0 9 0 -17.8 0 -17.7 -17.9 01/12/2005 12:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 45 4 305 305 9 0 9 0 -17.8 0 -17.7 -18.1 01/12/2005 12:40:00 0.4 0 0.4 0.4 7.8 0.2 8.4 7.2 0.4 0 0.4 0.4 45 5 305 305 9 0 9 0 -17.8 0 -17.5 -17.9 01/12/2005 12:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 45 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/12/2005 13:00:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 44 3 305 305 9 0 9 0 -17.7 0 -17.1 -17.9 01/12/2005 13:10:00 0.4 0 0.4 0.4 7.8 0.4 8.4 6.1 0.4 0 0.4 0.4 46 6 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/12/2005 13:20:00 0.4 0 0.4 0.4 7.9 0.3 8.4 6.5 0.4 0 0.4 0.4 44 4 305 305 9 0 9 0 -17.6 0 -17.5 -17.9 01/12/2005 13:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 44 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/12/2005 13:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 45 4 305 305 9 0 9 0 -17.5 0 -17.5 -17.7 01/12/2005 13:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 41 5 305 305 9 0 9 0 -17.5 0 -17.5 -17.7 01/12/2005 14:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 44 4 305 305 10 0 9 0 -17.5 0 -17.3 -17.5 01/12/2005 14:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 42 5 305 305 10 0 9 0 -17.4 0 -17.3 -17.5 01/12/2005 14:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 39 5 305 305 10 0 10 0 -17.4 0 -17.1 -17.5 01/12/2005 14:30:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 41 5 305 305 10 0 10 0 -17.4 0 -17.3 -17.5 01/12/2005 14:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 44 5 305 305 10 0 10 0 -17.5 0 -16.9 -17.5 01/12/2005 14:50:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 46 5 305 305 10 0 9 0 -17.5 0 -17.5 -17.7 01/12/2005 15:00:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 43 4 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/12/2005 15:10:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 45 4 305 305 9 0 9 0 -17.5 0 -17.5 -17.7 01/12/2005 15:20:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 43 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/12/2005 15:30:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 42 4 305 305 9 0 9 0 -17.5 0 -17.5 -17.7 01/12/2005 15:40:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 46 4 305 305 9 0 9 0 -17.5 0 -17.5 -17.7 01/12/2005 15:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 44 5 305 305 9 0 9 0 -17.5 0 -17.5 -17.7 01/12/2005 16:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 45 5 305 305 9 0 9 0 -17.4 0 -16.9 -17.5 01/12/2005 16:10:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 48 5 305 305 10 0 9 0 -17.4 0 -17.3 -17.5 01/12/2005 16:20:00 0.4 0 0.4 0.4 7.8 0.3 8.4 6.5 0.4 0 0.4 0.4 46 6 305 305 10 0 10 0 -17.3 0 -17.1 -17.5 01/12/2005 16:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 48 5 305 305 10 0 10 0 -17.3 0 -17.1 -17.5 01/12/2005 16:40:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 45 5 305 305 10 0 9 0 -17.3 0 -17.1 -17.5 01/12/2005 16:50:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 44 5 305 305 10 0 9 0 -17.3 0 -17.1 -17.5 01/12/2005 17:00:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 45 4 305 305 10 0 9 0 -17.4 0 -16.9 -17.5 01/12/2005 17:10:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 47 5 305 305 10 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 17:20:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 10 0 10 0 -17.3 0 -17.1 -17.5 01/12/2005 17:30:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 47 3 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/12/2005 17:40:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 47 4 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 17:50:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 49 4 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/12/2005 18:00:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 45 5 305 305 10 0 10 0 -17.4 0 -16.9 -17.5 01/12/2005 18:10:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 48 5 305 305 10 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 18:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 44 5 305 305 10 0 10 0 -17.3 0 -16.9 -17.5 01/12/2005 18:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 46 6 305 305 10 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 18:40:00 0.4 0 0.4 0.4 7.9 0.3 8.4 6.8 0.4 0 0.4 0.4 48 6 305 305 9 0 9 0 -17.4 0 -16.9 -17.5 01/12/2005 18:50:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 43 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.5 01/12/2005 19:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 44 5 305 305 9 0 9 0 -17.4 0 -16.9 -17.5 01/12/2005 19:10:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 46 5 305 305 10 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 19:20:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 46 4 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 19:30:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 42 4 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 19:40:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 42 4 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 19:50:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 41 4 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 20:00:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 42 4 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/12/2005 20:10:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.4 0 -16.9 -17.5 01/12/2005 20:20:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.4 0 -16.9 -17.5 01/12/2005 20:30:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 46 5 305 305 9 0 9 0 -17.4 0 -16.9 -17.5 01/12/2005 20:40:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.4 0.1 -16.9 -17.5 01/12/2005 20:50:00 0.4 0 0.4 0.4 8 0.2 8.4 7.2 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 21:00:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.4 0 -16.9 -17.5 01/12/2005 21:10:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 49 5 305 305 9 0 9 0 -17.5 0 -16.9 -17.7 01/12/2005 21:20:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 49 4 305 305 9 0 9 0 -17.5 0 -17.3 -17.5 01/12/2005 21:30:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 50 4 305 305 9 0 9 0 -17.5 0 -17.3 -17.5 01/12/2005 21:40:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 51 5 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/12/2005 21:50:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 51 5 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/12/2005 22:00:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 53 4 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/12/2005 22:10:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 52 4 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/12/2005 22:20:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 51 5 305 305 10 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 22:30:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 51 5 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 22:40:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 49 4 305 305 10 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 22:50:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 49 4 305 305 10 0 9 0 -17.3 0 -17.1 -17.5 01/12/2005 23:00:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 10 0 9 0 -17.3 0 -17.1 -17.5 01/12/2005 23:10:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 48 5 305 305 10 0 9 0 -17.3 0 -16.9 -17.5 01/12/2005 23:20:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -17.3 0 -16.9 -17.5 01/12/2005 23:30:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 23:40:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/12/2005 23:50:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 5 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/13/2005 00:00:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 4 305 305 9 0 9 0 -17.5 0 -16.9 -17.5 01/13/2005 00:10:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.5 01/13/2005 00:20:00 0.4 0 0.4 0.4 8.1 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.5 01/13/2005 00:30:00 0.4 0 0.4 0.4 8.1 0.1 8.4 7.6 0.4 0 0.4 0.4 46 4 305 305 9 0 9 0 -17.5 0 -17.5 -17.5 01/13/2005 00:40:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 45 6 305 305 9 0 9 0 -17.5 0 -16.9 -17.5 01/13/2005 00:50:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 49 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.5 01/13/2005 01:00:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.5 01/13/2005 01:10:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.7 01/13/2005 01:20:00 0.4 0 0.4 0.4 8.1 0.1 8.4 8 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/13/2005 01:30:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 46 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/13/2005 01:40:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/13/2005 01:50:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 47 4 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 02:00:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/13/2005 02:10:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 02:20:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 02:30:00 0.4 0 0.4 0.4 8.1 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 02:40:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.8 0 -17.5 -18.1 01/13/2005 02:50:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 03:00:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 50 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 03:10:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.9 01/13/2005 03:20:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 45 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 03:30:00 0.4 0 0.4 0.4 8.1 0.2 8.4 8 0.4 0 0.4 0.4 49 4 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 03:40:00 0.4 0 0.4 0.4 8.1 0.1 8.4 8 0.4 0 0.4 0.4 49 5 305 305 9 0 9 0 -17.8 0 -17.5 -17.9 01/13/2005 03:50:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 305 305 9 0 9 0 -17.8 0 -17.7 -17.9 01/13/2005 04:00:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -17.8 0 -17.3 -18.1 01/13/2005 04:10:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 46 4 305 305 9 0 9 0 -17.8 0 -17.7 -18.1 01/13/2005 04:20:00 0.4 0 0.4 0.4 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 47 4 305 305 9 0 9 0 -17.8 0 -17.7 -18.1 01/13/2005 04:30:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 4 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 04:40:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 4 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 04:50:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 50 4 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/13/2005 05:00:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.7 01/13/2005 05:10:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/13/2005 05:20:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 4 305 305 10 0 9 0 -17.3 0 -17.1 -17.5 01/13/2005 05:30:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 4 305 305 10 0 10 0 -17.3 0.1 -16.9 -17.5 01/13/2005 05:40:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 4 305 305 10 0 9 0 -17.3 0 -16.9 -17.5 01/13/2005 05:50:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 305 305 10 0 10 0 -17.2 0 -16.9 -17.3 01/13/2005 06:00:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 305 305 10 0 9 0 -17.2 0 -16.9 -17.5 01/13/2005 06:10:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 5 305 305 10 0 10 0 -17.1 0 -16.9 -17.3 01/13/2005 06:20:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -17.2 0 -16.9 -17.3 01/13/2005 06:30:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -17.1 0.1 -16.9 -17.3 01/13/2005 06:40:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -17.2 0 -16.9 -17.3 01/13/2005 06:50:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 5 305 305 10 0 9 0 -17.2 0 -16.9 -17.3 01/13/2005 07:00:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 41 5 305 305 10 0 10 0 -17.2 0.1 -16.9 -17.5 01/13/2005 07:10:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 41 5 305 305 10 0 10 0 -17.3 0 -17.1 -17.5 01/13/2005 07:20:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 305 305 10 0 9 0 -17.3 0 -16.9 -17.5 01/13/2005 07:30:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 305 305 10 0 9 0 -17.2 0.1 -16.9 -17.5 01/13/2005 07:40:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 44 6 305 305 10 0 10 0 -17.2 0 -16.9 -17.3 01/13/2005 07:50:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 42 5 305 305 10 0 9 0 -17.2 0 -16.9 -17.3 01/13/2005 08:00:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 42 5 305 305 10 0 9 0 -17.1 0 -16.9 -17.3 01/13/2005 08:10:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 42 5 305 305 10 0 10 0 -17.1 0 -16.9 -17.3 01/13/2005 08:20:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -17 0 -16.9 -17.1 01/13/2005 08:30:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 42 6 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 08:40:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 40 5 305 305 10 0 10 0 -17 0 -16.9 -16.9 01/13/2005 08:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 38 5 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 09:00:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 39 5 305 305 10 0 10 0 -16.9 0 -16.9 -17.1 01/13/2005 09:10:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 38 5 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 09:20:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 41 5 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 09:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 39 5 305 305 10 0 10 0 -16.9 0 -16.6 -16.9 01/13/2005 09:40:00 0.4 0 0.4 0.4 7.9 0.2 8 7.2 0.4 0 0.4 0.4 39 6 305 305 10 0 10 0 -16.9 0 -16.6 -16.9 01/13/2005 09:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 40 5 305 305 10 0 10 0 -16.9 0 -16.6 -16.9 01/13/2005 10:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 41 5 305 305 10 0 10 0 -16.9 0 -16.6 -16.9 01/13/2005 10:10:00 0.4 0 0.4 0.4 7.9 0.2 8 7.2 0.4 0 0.4 0.4 42 6 305 305 10 0 10 0 -16.9 0 -16.6 -16.9 01/13/2005 10:20:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 39 6 305 305 10 0 10 0 -16.8 0 -16.6 -16.9 01/13/2005 10:30:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 36 5 305 305 10 0 10 0 -16.9 0 -16.6 -16.9 01/13/2005 10:40:00 0.4 0 0.4 0.4 7.9 0.2 8 7.2 0.4 0 0.4 0.4 38 6 305 305 10 0 10 0 -16.9 0 -16.6 -16.9 01/13/2005 10:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 40 5 305 305 10 0 10 0 -16.9 0 -16.6 -16.9 01/13/2005 11:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 39 6 305 305 10 0 10 0 -16.7 0.1 -16.6 -16.9 01/13/2005 11:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 37 5 305 305 10 0 10 0 -16.8 0 -16.6 -16.9 01/13/2005 11:20:00 0.4 0 0.4 0.4 7.9 0.2 8 7.2 0.4 0 0.4 0.4 37 5 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 11:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 37 6 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 11:40:00 0.4 0 0.4 0.4 7.9 0.2 8 7.2 0.4 0 0.4 0.4 37 5 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 11:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 37 5 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 12:00:00 0.4 0 0.4 0.4 7.7 0.2 8 6.5 0.4 0 0.4 0.4 37 5 305 305 10 0 9 0 -16.9 0 -16.6 -16.9 01/13/2005 12:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 36 5 305 305 10 0 10 0 -16.8 0 -16.6 -16.9 01/13/2005 12:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 37 5 305 305 10 0 10 0 -16.9 0 -16.7 -16.9 01/13/2005 12:30:00 0.4 0 0.4 0.4 7.8 0.3 8 6.5 0.4 0 0.4 0.4 39 6 305 305 10 0 10 0 -16.9 0 -16.6 -16.9 01/13/2005 12:40:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 33 5 305 305 10 0 10 0 -16.9 0 -16.7 -16.9 01/13/2005 12:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 33 5 305 305 10 0 10 0 -16.9 0 -16.6 -16.9 01/13/2005 13:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 31 4 305 305 10 0 9 0 -16.9 0 -16.9 -16.9 01/13/2005 13:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 35 5 305 305 10 0 9 0 -16.9 0 -16.9 -16.9 01/13/2005 13:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 36 6 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 13:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 36 6 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 13:40:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 34 5 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 13:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 37 5 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 14:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 34 5 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 14:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 35 6 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 14:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 33 5 305 305 10 0 10 0 -16.9 0 -16.7 -16.9 01/13/2005 14:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 35 6 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/13/2005 14:40:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 35 5 305 305 10 0 10 0 -17 0 -16.9 -17.1 01/13/2005 14:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 37 5 305 305 10 0 9 0 -17.1 0.1 -16.9 -17.3 01/13/2005 15:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 36 5 305 305 10 0 9 0 -17.1 0 -16.9 -17.3 01/13/2005 15:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 34 4 305 305 10 0 10 0 -17.2 0 -16.9 -17.3 01/13/2005 15:20:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 36 5 305 305 9 0 9 0 -17.2 0 -16.9 -17.5 01/13/2005 15:30:00 0.4 0 0.4 0.4 7.7 0.3 8 6.5 0.4 0 0.4 0.4 34 6 305 305 10 0 9 0 -17.2 0 -16.9 -17.5 01/13/2005 15:40:00 0.4 0 0.4 0.4 7.8 0.3 8 6.5 0.4 0 0.4 0.4 33 5 305 305 9 0 10 0 -17.3 0.1 -16.9 -17.5 01/13/2005 15:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 36 5 305 305 9 0 9 0 -17.3 0.1 -16.9 -17.5 01/13/2005 16:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 34 6 305 305 9 0 9 0 -17.3 0 -16.9 -17.5 01/13/2005 16:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.3 0.1 -16.9 -17.5 01/13/2005 16:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 34 6 305 305 9 0 9 0 -17.3 0.1 -16.9 -17.5 01/13/2005 16:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 32 6 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/13/2005 16:40:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 31 6 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/13/2005 16:50:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 34 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.5 01/13/2005 17:00:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 34 5 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/13/2005 17:10:00 0.4 0 0.4 0.4 7.9 0.2 8 7.2 0.4 0 0.4 0.4 30 5 305 305 9 0 9 0 -17.5 0 -17.5 -17.7 01/13/2005 17:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.7 01/13/2005 17:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.7 01/13/2005 17:40:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 31 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.7 01/13/2005 17:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 30 5 305 305 9 0 9 0 -17.4 0 -16.9 -17.5 01/13/2005 18:00:00 0.4 0 0.4 0.4 7.9 0.2 8 7.2 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/13/2005 18:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 31 5 305 305 9 0 9 0 -17.3 0 -17.1 -17.5 01/13/2005 18:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 32 5 305 305 10 0 10 0 -17.4 0 -17.1 -17.5 01/13/2005 18:30:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 29 5 305 305 9 0 9 0 -17.3 0 -17.1 -17.5 01/13/2005 18:40:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 33 4 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/13/2005 18:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 32 6 305 305 9 0 9 0 -17.3 0.1 -17.1 -17.5 01/13/2005 19:00:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 33 7 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/13/2005 19:10:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 33 4 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/13/2005 19:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 33 5 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/13/2005 19:30:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 32 6 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/13/2005 19:40:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 33 6 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/13/2005 19:50:00 0.4 0 0.4 0.4 7.7 0.2 8 6.8 0.4 0 0.4 0.4 32 6 305 305 10 0 9 0 -17.3 0 -16.9 -17.5 01/13/2005 20:00:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 33 6 305 305 10 0 9 0 -17.3 0.1 -16.9 -17.5 01/13/2005 20:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 32 6 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/13/2005 20:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 33 6 305 305 9 0 9 0 -17.5 0 -17.1 -17.7 01/13/2005 20:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 31 5 305 305 9 0 9 0 -17.5 0 -17.5 -17.7 01/13/2005 20:40:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 34 6 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/13/2005 20:50:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 31 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 21:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 36 6 305 305 9 0 9 0 -17.6 0 -17.5 -17.9 01/13/2005 21:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 34 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.9 01/13/2005 21:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 34 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/13/2005 21:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.8 0 -17.5 -17.9 01/13/2005 21:40:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 35 6 305 305 9 0 9 0 -17.8 0 -17.5 -18.1 01/13/2005 21:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 32 6 305 305 9 0 9 0 -17.8 0 -17.5 -18.1 01/13/2005 22:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 34 5 305 305 9 0 8 0 -17.9 0 -17.7 -18.1 01/13/2005 22:10:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 33 5 305 305 9 0 9 0 -18 0 -17.7 -18.1 01/13/2005 22:20:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 31 5 305 305 8 0 9 0 -18 0 -17.9 -18.1 01/13/2005 22:30:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 34 6 305 305 8 0 8 0 -18 0 -17.9 -18.2 01/13/2005 22:40:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 30 4 305 305 8 0 8 0 -18.1 0 -18.1 -18.4 01/13/2005 22:50:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 33 5 305 305 8 0 8 0 -18.1 0 -17.7 -18.2 01/13/2005 23:00:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 31 5 305 305 8 0 8 0 -18.1 0 -18.1 -18.4 01/13/2005 23:10:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 30 4 305 305 8 0 8 0 -18.1 0 -18.1 -18.4 01/13/2005 23:20:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 33 5 305 305 8 0 8 0 -18.1 0 -18.1 -18.2 01/13/2005 23:30:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 32 5 305 305 8 0 8 0 -18.1 0 -17.7 -18.2 01/13/2005 23:40:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 29 5 305 305 9 0 8 0 -18 0 -17.9 -18.1 01/13/2005 23:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 33 5 305 305 9 0 9 0 -17.9 0 -17.7 -18.1 01/14/2005 00:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 32 5 305 305 9 0 8 0 -17.8 0 -17.5 -18.1 01/14/2005 00:10:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 34 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/14/2005 00:20:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 33 4 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/14/2005 00:30:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 33 5 305 305 9 0 9 0 -17.7 0 -17.5 -17.9 01/14/2005 00:40:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 31 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/14/2005 00:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.5 0 -17.5 -17.7 01/14/2005 01:00:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 30 5 305 305 9 0 9 0 -17.6 0 -17.5 -17.7 01/14/2005 01:10:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.5 0 -17.5 -17.7 01/14/2005 01:20:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.5 0 -17.5 -17.7 01/14/2005 01:30:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.5 01/14/2005 01:40:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/14/2005 01:50:00 0.4 0 0.4 0.4 7.8 0.2 8 6.8 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.3 0 -16.9 -17.5 01/14/2005 02:00:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 29 5 305 305 9 0 9 0 -17.4 0 -17.1 -17.5 01/14/2005 02:10:00 0.4 0 0.4 0.4 7.8 0.2 8 7.6 0.4 0 0.4 0.4 32 5 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/14/2005 02:20:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 34 5 305 305 9 0 9 0 -17.4 0 -17.3 -17.5 01/14/2005 02:30:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 34 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.5 01/14/2005 02:40:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 30 5 305 305 9 0 9 0 -17.5 0 -17.3 -17.7 01/14/2005 02:50:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 32 4 305 305 9 0 9 0 -17.5 0 -17.3 -17.5 01/14/2005 03:00:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 33 5 305 305 9 0 9 0 -17.4 0.1 -17.1 -17.5 01/14/2005 03:10:00 0.4 0 0.4 0.4 7.9 0.2 8 7.2 0.4 0 0.4 0.4 34 5 305 305 9 0 9 0 -17.4 0 -16.9 -17.5 01/14/2005 03:20:00 0.4 0 0.4 0.4 9.9 2.5 15.3 7.6 0.4 0 0.4 0.4 33 5 305 305 9 0 9 0 -17.2 0 -16.9 -17.3 01/14/2005 03:30:00 0.4 0 0.4 0.4 9.3 2.3 15.6 7.6 0.4 0 0.4 0.4 34 5 305 305 9 0 9 0 -17 0 -16.9 -17.1 01/14/2005 03:40:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 34 5 305 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 03:50:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 32 6 305 305 10 0 9 0 -16.9 0 -16.9 -17.1 01/14/2005 04:00:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 31 5 305 305 10 0 10 0 -16.9 0 -16.6 -16.9 01/14/2005 04:10:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 33 5 305 305 10 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 04:20:00 0.4 0 0.4 0.4 7.8 0.2 8 7.2 0.4 0 0.4 0.4 31 6 305 305 10 0 9 0 -16.9 0 -16.6 -16.9 01/14/2005 04:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 31 5 305 305 10 0 10 0 -16.8 0 -16.6 -16.9 01/14/2005 04:40:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 35 5 305 305 10 0 10 0 -16.6 0 -16.4 -16.9 01/14/2005 04:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 33 5 305 305 10 0 10 0 -16.7 0 -16.4 -16.9 01/14/2005 05:00:00 0.4 0 0.4 0.4 10.3 2.7 14.9 7.6 0.4 0 0.4 0.4 33 5 305 305 10 0 10 0 -16.7 0 -16.4 -16.9 01/14/2005 05:10:00 0.4 0 0.4 0.4 13.4 1.5 16.1 7.6 0.4 0 0.4 0.4 34 5 305 305 10 0 10 0 -16.7 0.1 -16.4 -16.9 01/14/2005 05:20:00 0.4 0 0.4 0.4 9.7 2.7 15.3 7.6 0.4 0 0.4 0.4 33 5 305 305 10 0 10 0 -16.6 0 -16.4 -16.7 01/14/2005 05:30:00 0.4 0 0.4 0.4 9.9 2.9 16.8 7.6 0.4 0 0.4 0.4 34 5 305 305 10 0 10 0 -16.6 0 -16.4 -16.9 01/14/2005 05:40:00 0.4 0 0.4 0.4 10 2.9 16.1 7.6 0.4 0 0.4 0.4 36 5 305 305 10 0 10 0 -16.7 0.1 -16.4 -16.9 01/14/2005 05:50:00 0.4 0 0.4 0.4 9.7 2.6 16.1 7.6 0.4 0 0.4 0.4 34 6 305 305 10 0 10 0 -16.8 0 -16.6 -16.9 01/14/2005 06:00:00 0.4 0 0.4 0.4 11.1 2.8 16.1 7.6 0.4 0 0.4 0.4 33 5 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/14/2005 06:10:00 0.4 0 0.4 0.4 14.3 1.1 16.4 10.7 0.4 0 0.4 0.4 35 4 305 305 10 0 10 0 -16.9 0 -16.9 -16.9 01/14/2005 06:20:00 0.4 0 0.4 0.4 13.6 1.4 17.2 10.3 0.4 0 0.4 0.4 34 5 305 305 10 0 9 0 -17 0 -16.9 -17.1 01/14/2005 06:30:00 0.4 0 0.4 0.4 14.3 1.5 18.3 10.7 0.4 0 0.4 0.4 37 5 305 305 10 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 06:40:00 0.4 0 0.4 0.4 13.6 1.8 17.6 9.9 0.4 0 0.4 0.4 35 5 305 305 10 0 9 0 -17 0 -16.9 -17.1 01/14/2005 06:50:00 0.4 0 0.4 0.4 13.8 1.8 17.2 7.6 0.4 0 0.4 0.4 35 5 305 305 9 0 9 0 -17 0 -16.9 -17.1 01/14/2005 07:00:00 0.4 0 0.4 0.4 14.6 1.4 18.7 12.2 0.4 0 0.4 0.4 38 5 305 305 9 0 9 0 -17 0 -16.9 -17.1 01/14/2005 07:10:00 0.4 0 0.4 0.4 11.7 3.2 16.8 7.6 0.4 0 0.4 0.4 36 5 305 305 9 0 9 0 -17 0 -16.9 -17.1 01/14/2005 07:20:00 0.4 0 0.4 0.4 14.3 1.5 17.6 11.1 0.4 0 0.4 0.4 34 5 305 305 9 0 9 0 -17 0 -16.9 -17.1 01/14/2005 07:30:00 0.4 0 0.4 0.4 14.2 1.4 17.6 10.7 0.4 0 0.4 0.4 34 4 305 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 07:40:00 0.4 0 0.4 0.4 11.5 2.4 16.8 7.6 0.4 0 0.4 0.4 34 6 305 305 10 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 07:50:00 0.4 0 0.4 0.4 14.7 1.7 17.6 9.9 0.4 0 0.4 0.4 36 5 305 305 10 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 08:00:00 0.4 0 0.4 0.4 13.3 1.9 16.8 7.6 0.4 0 0.4 0.4 35 5 305 305 10 0 10 0 -16.8 0 -16.4 -16.9 01/14/2005 08:10:00 0.4 0 0.4 0.4 13.6 2 17.9 7.6 0.4 0 0.4 0.4 37 5 305 305 10 0 10 0 -16.8 0 -16.6 -16.9 01/14/2005 08:20:00 0.4 0 0.4 0.4 14 1.6 18.3 11.1 0.4 0 0.4 0.4 35 5 305 305 10 0 9 0 -16.9 0 -16.6 -16.9 01/14/2005 08:30:00 0.4 0 0.4 0.4 14.6 1.6 17.6 11.1 0.4 0 0.4 0.4 35 5 305 305 10 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 08:40:00 0.4 0 0.4 0.4 14.5 1.7 18.3 9.9 0.4 0 0.4 0.4 35 5 305 305 10 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 08:50:00 0.4 0 0.4 0.4 14.6 1.6 18.3 10.3 0.4 0 0.4 0.4 37 5 305 305 10 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 09:00:00 0.4 0 0.4 0.4 12.7 3.1 18.3 7.2 0.4 0 0.4 0.4 36 5 305 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/14/2005 09:10:00 0.4 0 0.4 0.4 14.4 1.6 18.3 9.9 0.4 0 0.4 0.4 36 5 305 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 09:20:00 0.4 0 0.4 0.4 15.3 1.3 18.7 11.8 0.4 0 0.4 0.4 36 5 305 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 09:30:00 0.4 0 0.4 0.4 14 1.5 17.9 10.7 0.4 0 0.4 0.4 36 5 305 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/14/2005 09:40:00 0.4 0 0.4 0.4 14.7 1.7 18.7 10.7 0.4 0 0.4 0.4 35 5 305 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/14/2005 09:50:00 0.4 0 0.4 0.4 14.3 1.7 18.7 10.3 0.4 0 0.4 0.4 39 6 305 305 9 0 9 0 -16.9 0 -16.4 -16.9 01/14/2005 10:00:00 0.4 0 0.4 0.4 14 1.5 18.7 10.3 0.4 0 0.4 0.4 40 5 305 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/14/2005 10:10:00 0.4 0 0.4 0.4 13.6 1.5 17.6 10.3 0.4 0 0.4 0.4 38 5 305 305 9 0 9 0 -16.9 0 -16.7 -16.9 01/14/2005 10:20:00 0.4 0 0.4 0.4 14.1 1.4 17.6 11.1 0.4 0 0.4 0.4 38 5 305 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/14/2005 10:30:00 0.4 0 0.4 0.4 13.9 1.6 17.9 10.3 0.4 0 0.4 0.4 39 5 305 305 9 0 9 0 -16.7 0.1 -16.6 -16.9 01/14/2005 10:40:00 0.4 0 0.4 0.4 14.2 1.4 17.6 10.7 0.4 0 0.4 0.4 40 5 305 305 9 0 9 0 -16.7 0 -16.6 -16.9 01/14/2005 10:50:00 0.4 0 0.4 0.4 13.4 2.2 17.6 7.6 0.4 0 0.4 0.4 36 5 305 305 10 0 9 0 -16.7 0 -16.6 -16.9 01/14/2005 11:00:00 0.4 0 0.4 0.4 11.8 2.9 16.8 7.6 0.4 0 0.4 0.4 38 6 305 305 10 0 9 0 -16.6 0 -16.4 -16.9 01/14/2005 11:10:00 0.4 0 0.4 0.4 13.3 1.2 16.1 9.9 0.4 0 0.4 0.4 38 5 305 305 10 0 10 0 -16.5 0 -16.4 -16.6 01/14/2005 11:20:00 0.4 0 0.4 0.4 13.7 1.7 17.6 7.6 0.4 0 0.4 0.4 38 5 305 305 10 0 10 0 -16.4 0 -16.4 -16.6 01/14/2005 11:30:00 0.4 0 0.4 0.4 14 1.6 17.9 10.7 0.4 0 0.4 0.4 40 5 305 305 10 0 10 0 -16.4 0 -16.4 -16.6 01/14/2005 11:40:00 0.4 0 0.4 0.4 13.7 1.8 17.2 7.6 0.4 0 0.4 0.4 36 4 305 305 10 0 10 0 -16.4 0 -16.4 -16.6 01/14/2005 11:50:00 0.4 0 0.4 0.4 13.9 2.8 17.9 7.6 0.4 0 0.4 0.4 36 4 305 305 10 0 10 0 -16.4 0 -16.4 -16.6 01/14/2005 12:00:00 0.4 0 0.4 0.4 14.1 1.4 18.3 9.9 0.4 0 0.4 0.4 35 4 305 305 10 0 10 0 -16.4 0 -16.4 -16.6 01/14/2005 12:10:00 0.4 0 0.4 0.4 14.2 1.5 17.9 9.9 0.4 0 0.4 0.4 38 5 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 12:20:00 0.4 0 0.4 0.4 12 2.8 17.6 7.6 0.4 0 0.4 0.4 37 5 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 12:30:00 0.4 0 0.4 0.4 13.4 1.7 16.4 7.6 0.4 0 0.4 0.4 38 6 305 305 10 0 10 0 -16.4 0 -16.4 -16.6 01/14/2005 12:40:00 0.4 0 0.4 0.4 11.1 2.8 16.4 7.6 0.4 0 0.4 0.4 36 5 305 305 10 0 9 0 -16.5 0 -16.4 -16.6 01/14/2005 12:50:00 0.4 0 0.4 0.4 13 1.5 16.4 7.6 0.4 0 0.4 0.4 37 5 305 305 10 0 9 0 -16.6 0 -16.4 -16.7 01/14/2005 13:00:00 0.4 0 0.4 0.4 12.3 2.9 16.8 7.6 0.4 0 0.4 0.4 38 5 305 305 10 0 10 0 -16.5 0 -16.4 -16.6 01/14/2005 13:10:00 0.4 0 0.4 0.4 12 2.9 17.2 7.6 0.4 0 0.4 0.4 37 6 305 305 10 0 10 0 -16.4 0 -16.4 -16.6 01/14/2005 13:20:00 0.4 0 0.4 0.4 10.6 2.7 16.4 7.6 0.4 0 0.4 0.4 37 6 305 305 10 0 10 0 -16.4 0 -16.4 -16.6 01/14/2005 13:30:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 35 6 305 305 10 0 10 0 -16.5 0 -16.4 -16.6 01/14/2005 13:40:00 0.4 0 0.4 0.4 7.9 0.2 8 7.6 0.4 0 0.4 0.4 36 5 305 305 10 0 9 0 -16.4 0 -16.2 -16.6 01/14/2005 13:50:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 35 5 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 14:00:00 0.4 0 0.4 0.4 10.1 2.7 14.9 7.6 0.4 0 0.4 0.4 37 5 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 14:10:00 0.4 0 0.4 0.4 9.8 2.5 15.6 7.6 0.4 0 0.4 0.4 35 6 305 305 10 0 10 0 -16.4 0 -16 -16.6 01/14/2005 14:20:00 0.4 0 0.4 0.4 10 2.8 16.4 7.6 0.4 0 0.4 0.4 37 5 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 14:30:00 0.4 0 0.4 0.4 9 2 14.9 7.6 0.4 0 0.4 0.4 36 5 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 14:40:00 0.4 0 0.4 0.4 9.4 2.4 14.9 7.6 0.4 0 0.4 0.4 37 5 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 14:50:00 0.4 0 0.4 0.4 11.8 2.9 16.4 7.6 0.4 0 0.4 0.4 38 5 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 15:00:00 0.4 0 0.4 0.4 12.4 2.4 16.4 7.6 0.4 0 0.4 0.4 38 5 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 15:10:00 0.4 0 0.4 0.4 13.4 1.8 16.4 7.6 0.4 0 0.4 0.4 40 5 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 15:20:00 0.4 0 0.4 0.4 13 1.5 17.2 9.9 0.4 0 0.4 0.4 39 5 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 15:30:00 0.4 0 0.4 0.4 13.8 1.3 16.8 10.3 0.4 0 0.4 0.4 41 5 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 15:40:00 0.4 0 0.4 0.4 12.6 1.1 15.3 9.9 0.4 0 0.4 0.4 38 5 305 305 10 0 10 0 -16.4 0 -16 -16.6 01/14/2005 15:50:00 0.4 0 0.4 0.4 13.1 2.2 16.4 7.6 0.4 0 0.4 0.4 39 5 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 16:00:00 0.4 0 0.4 0.4 13.3 2 17.2 7.6 0.4 0 0.4 0.4 39 5 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 16:10:00 0.4 0 0.4 0.4 11.6 2.5 16.1 7.6 0.4 0 0.4 0.4 39 5 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 16:20:00 0.4 0 0.4 0.4 12.4 2.1 16.1 7.6 0.4 0 0.4 0.4 40 4 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 16:30:00 0.4 0 0.4 0.4 12.8 1.2 16.4 10.3 0.4 0 0.4 0.4 39 5 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 16:40:00 0.4 0 0.4 0.4 13.4 1.3 16.4 9.9 0.4 0 0.4 0.4 41 5 305 305 10 0 10 0 -16.3 0 -16.2 -16.4 01/14/2005 16:50:00 0.4 0 0.4 0.4 11.6 2.4 15.3 7.6 0.4 0 0.4 0.4 39 4 305 305 10 0 9 0 -16.3 0 -16.2 -16.4 01/14/2005 17:00:00 0.4 0 0.4 0.4 11.2 2.8 15.3 7.2 0.4 0 0.4 0.4 40 5 305 305 10 0 10 0 -16.2 0 -16 -16.4 01/14/2005 17:10:00 0.4 0 0.4 0.4 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 40 5 305 305 10 0 10 0 -16 0 -15.8 -16.2 01/14/2005 17:20:00 0.4 0 0.4 0.4 8.7 1.9 14.9 7.6 0.4 0 0.4 0.4 40 5 305 305 10 0 10 0 -15.9 0 -15.8 -16 01/14/2005 17:30:00 0.4 0 0.4 0.4 11 2.6 16.8 7.6 0.4 0 0.4 0.4 42 5 305 305 10 0 10 0 -15.8 0 -15.8 -16 01/14/2005 17:40:00 0.4 0 0.4 0.4 10.6 2.7 15.3 7.6 0.4 0 0.4 0.4 38 5 305 305 10 0 10 0 -15.9 0.1 -15.8 -16.2 01/14/2005 17:50:00 0.4 0 0.4 0.4 13.1 1.3 15.6 9.5 0.4 0 0.4 0.4 39 4 305 305 10 0 10 0 -16.1 0 -16 -16.2 01/14/2005 18:00:00 0.4 0 0.4 0.4 12.2 2.8 16.8 7.6 0.4 0 0.4 0.4 41 5 305 305 10 0 10 0 -16.1 0 -15.8 -16.2 01/14/2005 18:10:00 0.4 0 0.4 0.4 13.8 1.4 17.2 9.5 0.4 0 0.4 0.4 41 4 305 305 10 0 10 0 -16.1 0 -16 -16.4 01/14/2005 18:20:00 0.4 0 0.4 0.4 13 2.6 17.2 7.6 0.4 0 0.4 0.4 40 5 305 305 10 0 10 0 -16.1 0 -15.8 -16.2 01/14/2005 18:30:00 0.4 0 0.4 0.4 13.5 1.5 16.4 10.3 0.4 0 0.4 0.4 41 5 305 305 10 0 10 0 -16.1 0 -15.8 -16.2 01/14/2005 18:40:00 0.4 0 0.4 0.4 14.2 1.2 17.2 11.1 0.4 0 0.4 0.4 42 4 305 305 10 0 10 0 -16.1 0 -15.8 -16.2 01/14/2005 18:50:00 0.4 0 0.4 0.4 13.5 1.3 16.4 9.9 0.4 0 0.4 0.4 40 5 305 305 10 0 10 0 -16.1 0.1 -15.8 -16.4 01/14/2005 19:00:00 0.4 0 0.4 0.4 13.7 1.4 16.8 10.7 0.4 0 0.4 0.4 42 4 305 305 10 0 10 0 -16.2 0 -16 -16.4 01/14/2005 19:10:00 0.4 0 0.4 0.4 13.7 1.3 16.4 10.7 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 19:20:00 0.4 0 0.4 0.4 13.5 1.3 16.8 9.9 0.4 0 0.4 0.4 44 5 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 19:30:00 0.4 0 0.4 0.4 14.9 1.3 17.6 11.5 0.4 0 0.4 0.4 44 4 305 305 10 0 10 0 -16.4 0 -16.2 -16.6 01/14/2005 19:40:00 0.4 0 0.4 0.4 15.5 1.1 17.9 12.6 0.4 0 0.4 0.4 43 4 305 305 10 0 9 0 -16.3 0 -16 -16.4 01/14/2005 19:50:00 0.4 0 0.4 0.4 14.8 1.2 17.2 11.1 0.4 0 0.4 0.4 41 4 305 305 10 0 10 0 -16.4 0 -16 -16.6 01/14/2005 20:00:00 0.4 0 0.4 0.4 14.6 1.6 17.9 10.7 0.4 0 0.4 0.4 43 4 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 20:10:00 0.4 0 0.4 0.4 13.9 1.5 17.6 10.7 0.4 0 0.4 0.4 43 4 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 20:20:00 0.4 0 0.4 0.4 14.3 1.3 16.8 11.1 0.4 0 0.4 0.4 41 4 305 305 10 0 9 0 -16.3 0 -16.2 -16.4 01/14/2005 20:30:00 0.4 0 0.4 0.4 14.8 1.2 17.6 10.7 0.4 0 0.4 0.4 42 4 305 305 10 0 9 0 -16.3 0 -16.2 -16.4 01/14/2005 20:40:00 0.4 0 0.4 0.4 14.8 1.5 17.6 11.1 0.4 0 0.4 0.4 40 3 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 20:50:00 0.4 0 0.4 0.4 15 1.1 17.6 11.5 0.4 0 0.4 0.4 41 4 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 21:00:00 0.4 0 0.4 0.4 14.4 1.3 16.8 11.1 0.4 0 0.4 0.4 41 3 305 305 10 0 9 0 -16.3 0 -16 -16.4 01/14/2005 21:10:00 0.4 0 0.4 0.4 13.8 1.1 16.8 10.7 0.4 0 0.4 0.4 44 4 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 21:20:00 0.4 0 0.4 0.4 13.5 1.3 16.4 9.9 0.4 0 0.4 0.4 45 5 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 21:30:00 0.4 0 0.4 0.4 13.1 1 15.6 10.7 0.4 0 0.4 0.4 43 4 305 305 10 0 9 0 -16.3 0 -16 -16.4 01/14/2005 21:40:00 0.4 0 0.4 0.4 13.2 1 16.1 10.3 0.4 0 0.4 0.4 45 5 305 305 10 0 9 0 -16.3 0 -16.2 -16.4 01/14/2005 21:50:00 0.4 0 0.4 0.4 13.5 1.2 16.4 10.3 0.4 0 0.4 0.4 44 4 305 305 10 0 10 0 -16.3 0 -16.2 -16.4 01/14/2005 22:00:00 0.4 0 0.4 0.4 12.6 1 15.3 10.3 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 22:10:00 0.4 0 0.4 0.4 10.3 2.3 14.5 7.6 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -16.3 0 -16 -16.4 01/14/2005 22:20:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 305 305 10 0 10 0 -16.2 0 -16 -16.4 01/14/2005 22:30:00 0.4 0 0.4 0.4 8.3 1.2 13.3 7.6 0.4 0 0.4 0.4 43 5 305 305 10 0 10 0 -16.2 0 -16 -16.4 01/14/2005 22:40:00 0.4 0 0.4 0.4 10.7 2.6 14.9 7.6 0.4 0 0.4 0.4 40 5 305 305 10 0 10 0 -16.3 0.1 -16 -16.4 01/14/2005 22:50:00 0.4 0 0.4 0.4 13 1.3 16.4 9.9 0.4 0 0.4 0.4 39 4 305 305 10 0 10 0 -16.2 0 -16 -16.4 01/14/2005 23:00:00 0.4 0 0.4 0.4 14 1 16.4 11.1 0.4 0 0.4 0.4 37 3 305 305 10 0 10 0 -16.1 0 -15.8 -16.2 01/14/2005 23:10:00 0.4 0 0.4 0.4 13.7 1.6 16.1 7.6 0.4 0 0.4 0.4 36 3 305 305 10 0 10 0 -16 0 -15.8 -16.2 01/14/2005 23:20:00 0.4 0 0.4 0.4 13.1 1 15.3 10.7 0.4 0 0.4 0.4 37 4 305 305 10 0 10 0 -16 0 -15.8 -16.2 01/14/2005 23:30:00 0.4 0 0.4 0.4 14 1 16.4 10.7 0.4 0 0.4 0.4 38 4 305 305 10 0 10 0 -16 0 -15.6 -16.2 01/14/2005 23:40:00 0.4 0 0.4 0.4 13.6 1.1 16.1 10.7 0.4 0 0.4 0.4 39 4 305 305 10 0 10 0 -16.1 0 -15.8 -16.2 01/14/2005 23:50:00 0.4 0 0.4 0.4 13.3 1 15.6 11.5 0.4 0 0.4 0.4 42 4 305 305 10 0 10 0 -16.1 0 -15.8 -16.2 01/15/2005 00:00:00 0.4 0 0.4 0.4 12.8 1 15.6 10.3 0.4 0 0.4 0.4 45 4 305 305 10 0 9 0 -16.1 0 -15.8 -16.2 01/15/2005 00:10:00 0.4 0 0.4 0.4 10.6 2.4 14.5 7.6 0.4 0 0.4 0.4 47 5 305 305 10 0 10 0 -16 0 -15.8 -16.2 01/15/2005 00:20:00 0.4 0 0.4 0.4 8.9 2.3 16.1 7.6 0.4 0 0.4 0.4 51 5 305 305 10 0 10 0 -15.9 0 -15.8 -16 01/15/2005 00:30:00 0.4 0 0.4 0.4 13.1 1.1 15.3 10.3 0.4 0 0.4 0.4 48 5 305 305 10 0 10 0 -15.9 0 -15.8 -16.2 01/15/2005 00:40:00 0.4 0 0.4 0.4 13.1 1.1 15.6 9.9 0.4 0 0.4 0.4 46 5 305 305 10 0 10 0 -16 0 -15.8 -16.2 01/15/2005 00:50:00 0.4 0 0.4 0.4 12.2 1.2 15.6 9.5 0.4 0 0.4 0.4 43 4 305 305 10 0 10 0 -16 0 -15.8 -16.2 01/15/2005 01:00:00 0.4 0 0.4 0.4 12.8 1.1 15.6 10.3 0.4 0 0.4 0.4 44 4 305 305 10 0 10 0 -16.1 0.1 -15.8 -16.4 01/15/2005 01:10:00 0.4 0 0.4 0.4 12.9 1.1 15.3 10.7 0.4 0 0.4 0.4 45 4 305 305 10 0 9 0 -16.2 0 -16 -16.4 01/15/2005 01:20:00 0.4 0 0.4 0.4 13.5 0.9 15.6 10.7 0.4 0 0.4 0.4 45 3 305 305 10 0 9 0 -16.3 0 -16 -16.4 01/15/2005 01:30:00 0.4 0 0.4 0.4 12.9 1.1 15.3 10.7 0.4 0 0.4 0.4 44 5 305 305 9 0 9 0 -16.3 0 -16.2 -16.4 01/15/2005 01:40:00 0.4 0 0.4 0.4 11.7 1.9 15.6 7.6 0.4 0 0.4 0.4 44 5 305 305 9 0 9 0 -16.3 0 -16 -16.4 01/15/2005 01:50:00 0.4 0 0.4 0.4 10.1 2.4 14.5 7.6 0.4 0 0.4 0.4 44 5 305 305 9 0 9 0 -16.3 0 -16 -16.4 01/15/2005 02:00:00 0.4 0 0.4 0.4 9.1 2.1 14.9 7.6 0.4 0 0.4 0.4 43 4 305 305 9 0 9 0 -16.3 0 -16 -16.4 01/15/2005 02:10:00 0.4 0 0.4 0.4 12.7 1.2 15.6 9.5 0.4 0 0.4 0.4 44 5 305 305 9 0 9 0 -16.3 0 -16.2 -16.6 01/15/2005 02:20:00 0.4 0 0.4 0.4 11 2.1 14.5 7.6 0.4 0 0.4 0.4 45 4 305 305 9 0 9 0 -16.3 0 -16.2 -16.6 01/15/2005 02:30:00 0.4 0 0.4 0.4 8 0.2 8.4 7.6 0.4 0 0.4 0.4 43 5 305 305 9 0 9 0 -16.4 0 -16.4 -16.6 01/15/2005 02:40:00 0.4 0 0.4 0.4 10.4 2.8 16.4 7.6 0.4 0 0.4 0.4 44 4 305 305 9 0 9 0 -16.6 0 -16.4 -16.9 01/15/2005 02:50:00 0.4 0 0.4 0.4 12.6 1 14.9 10.3 0.4 0 0.4 0.4 44 4 305 305 9 0 9 0 -16.6 0 -16.4 -16.7 01/15/2005 03:00:00 0.4 0 0.4 0.4 12.1 1.9 15.3 7.6 0.4 0 0.4 0.4 43 4 305 305 9 0 9 0 -16.7 0 -16.4 -16.9 01/15/2005 03:10:00 0.4 0 0.4 0.4 9.5 2.5 15.3 7.6 0.4 0 0.4 0.4 44 4 305 305 9 0 9 0 -16.7 0 -16.6 -16.9 01/15/2005 03:20:00 0.4 0 0.4 0.4 12 2.1 15.3 7.6 0.4 0 0.4 0.4 44 4 305 305 9 0 9 0 -16.7 0.1 -16.6 -16.9 01/15/2005 03:30:00 0.4 0 0.4 0.4 12 1.3 14.1 7.6 0.4 0 0.4 0.4 44 5 305 305 9 0 9 0 -16.7 0.1 -16.6 -16.9 01/15/2005 03:40:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -16.7 0.1 -16.6 -16.9 01/15/2005 03:50:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 4 305 305 9 0 9 0 -16.8 0.1 -16.6 -16.9 01/15/2005 04:00:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 305 305 9 0 9 0 -16.8 0 -16.6 -16.9 01/15/2005 04:10:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 4 305 305 9 0 9 0 -16.8 0 -16.6 -16.9 01/15/2005 04:20:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 4 305 305 9 0 9 0 -16.9 0 -16.7 -16.9 01/15/2005 04:30:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 4 305 305 9 0 8 0 -16.9 0 -16.9 -16.9 01/15/2005 04:40:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 305 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 04:50:00 0.4 0 0.4 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 5 305 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 05:00:00 0.4 0 0.4 0.4 8 0.1 8 7.6 0.4 0 0.4 0.4 46 5 305 305 9 0 8 0 -16.9 0 -16.9 -16.9 01/15/2005 05:10:00 6.9 1.9 11.5 0.4 8 0.1 8.4 7.6 0.4 0 0.4 0.4 43 5 41 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 05:20:00 10.2 1.8 13.3 6.8 8 0.1 8.4 7.6 0.4 0 0.4 0.4 42 4 38 305 9 0 9 0 -16.9 0 -16.7 -16.9 01/15/2005 05:30:00 11.9 1.4 14.5 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 42 5 41 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 05:40:00 11.5 1.1 14.1 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 43 5 41 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 05:50:00 12 1 14.1 9.5 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 46 305 9 0 9 0 -16.9 0 -16.7 -16.9 01/15/2005 06:00:00 11.8 0.9 14.5 9.1 8.9 1.7 13.3 7.6 0.4 0 0.4 0.4 46 4 46 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 06:10:00 11.8 1.3 14.1 7.2 8.7 1.7 13.7 7.6 0.4 0 0.4 0.4 44 5 40 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 06:20:00 11.7 1.2 14.1 7.2 8.3 1.1 12.6 7.6 0.4 0 0.4 0.4 44 5 47 305 9 0 9 0 -17 0 -16.9 -17.1 01/15/2005 06:30:00 11.5 1.5 14.1 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 41 5 43 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 06:40:00 10.7 2 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 42 5 36 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 06:50:00 7.9 1.1 13 7.2 7.9 0.1 8.4 7.6 0.4 0 0.4 0.4 43 5 42 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 07:00:00 10.2 1.7 13 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 41 5 39 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 07:10:00 9.9 1.9 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 39 5 35 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 07:20:00 9.5 1.8 12.6 6.8 7.9 0.1 8.4 7.6 0.4 0 0.4 0.4 39 5 40 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 07:30:00 8.6 1.7 12.6 6.8 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 42 5 42 305 9 0 9 0 -16.9 0 -16.7 -16.9 01/15/2005 07:40:00 9.1 2.1 13.7 6.8 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 36 4 31 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 07:50:00 11.1 1.8 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 36 4 39 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 08:00:00 7.8 1 12.6 6.8 7.8 0.2 8 6.8 0.4 0 0.4 0.4 36 5 37 305 9 0 8 0 -16.9 0 -16.9 -16.9 01/15/2005 08:10:00 7.5 0.2 8 7.2 7.9 0.2 8 7.6 0.4 0 0.4 0.4 37 5 42 305 9 0 8 0 -16.9 0 -16.9 -17.1 01/15/2005 08:20:00 10.5 1.7 13 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 39 5 32 305 9 0 9 0 -16.9 0 -16.9 -17.1 01/15/2005 08:30:00 11.8 0.9 13.7 9.1 8 0.1 8.4 7.6 0.4 0 0.4 0.4 40 5 32 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 08:40:00 10.9 1.6 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 40 4 33 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 08:50:00 9.8 2 13.3 7.2 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 42 5 40 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 09:00:00 9.3 1.7 12.6 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 41 305 9 0 9 0 -16.9 0 -16.7 -16.9 01/15/2005 09:10:00 7.8 1 12.6 6.8 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 47 6 42 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 09:20:00 8.3 1.5 12.2 6.8 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 47 5 43 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 09:30:00 9.5 1.7 12.6 7.2 7.9 0.1 8 7.2 0.4 0 0.4 0.4 47 5 51 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 09:40:00 11.3 1 13.3 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 4 44 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 09:50:00 11.3 0.8 13.3 9.1 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 46 305 9 0 9 0 -16.9 0 -16.7 -16.9 01/15/2005 10:00:00 11 1 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 45 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 10:10:00 11.4 0.9 14.1 8.8 8 0.1 8.4 7.6 0.4 0 0.4 0.4 43 5 34 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 10:20:00 11.6 1.5 14.1 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 42 5 39 305 9 0 9 0 -16.9 0 -16.7 -16.9 01/15/2005 10:30:00 11.8 1.6 14.9 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 42 5 41 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 10:40:00 12.4 0.8 14.5 10.3 8 0.1 8.4 7.6 0.4 0 0.4 0.4 40 5 40 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 10:50:00 13.4 1 15.6 10.7 10.5 2.8 15.6 7.6 0.4 0 0.4 0.4 40 5 40 305 9 0 9 0 -17 0 -16.9 -17.1 01/15/2005 11:00:00 13.7 1 15.6 10.7 13.5 1.2 16.1 10.3 0.4 0 0.4 0.4 41 4 44 305 9 0 8 0 -17 0 -16.9 -17.1 01/15/2005 11:10:00 13 1 15.6 10.7 12.8 1.1 15.6 10.7 0.4 0 0.4 0.4 42 5 40 305 9 0 9 0 -17.1 0 -16.9 -17.3 01/15/2005 11:20:00 13.2 1.1 15.3 7.2 13 1 15.3 10.7 0.4 0 0.4 0.4 42 4 44 305 9 0 8 0 -17.1 0 -16.9 -17.3 01/15/2005 11:30:00 12.7 1 14.9 9.5 11.8 2 14.9 7.6 0.4 0 0.4 0.4 42 4 43 305 9 0 9 0 -17.1 0 -16.9 -17.3 01/15/2005 11:40:00 12.5 1.7 15.6 7.2 12 1.8 14.9 7.6 0.4 0 0.4 0.4 44 5 33 305 9 0 8 0 -17.1 0 -16.9 -17.3 01/15/2005 11:50:00 12.3 1 14.9 9.5 10.9 2.1 14.5 7.6 0.4 0 0.4 0.4 44 5 42 305 9 0 9 0 -17.1 0 -16.9 -17.3 01/15/2005 12:00:00 11.8 0.9 14.1 9.5 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 5 44 305 9 0 9 0 -17.1 0 -16.9 -17.1 01/15/2005 12:10:00 11.6 1 13.7 9.1 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 39 305 9 0 9 0 -17 0 -16.9 -17.1 01/15/2005 12:20:00 11.1 1.4 13.7 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 41 305 9 0 9 0 -17 0 -16.9 -17.1 01/15/2005 12:30:00 10.3 1.7 13.7 7.2 7.9 0.1 8.4 7.6 0.4 0 0.4 0.4 41 4 38 305 9 0 9 0 -17 0 -16.9 -17.1 01/15/2005 12:40:00 10 2.3 13.7 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 40 5 44 305 9 0 9 0 -17 0 -16.9 -17.3 01/15/2005 12:50:00 8.6 1.9 13.3 6.8 7.9 0.2 8.4 6.8 0.4 0 0.4 0.4 41 5 37 305 9 0 9 0 -17 0 -16.9 -17.1 01/15/2005 13:00:00 7.3 0.3 7.6 6.1 7.6 0.4 8 6.1 0.4 0 0.4 0.4 45 6 39 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 13:10:00 7.3 0.3 8 6.5 7.7 0.3 8 6.8 0.4 0 0.4 0.4 45 5 40 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 13:20:00 7.4 0.2 7.6 6.8 7.8 0.2 8 7.2 0.4 0 0.4 0.4 41 5 43 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 13:30:00 7.5 0.2 8 7.2 7.9 0.2 8 7.6 0.4 0 0.4 0.4 44 4 44 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 13:40:00 7.5 0.4 9.9 6.8 7.9 0.2 8 6.8 0.4 0 0.4 0.4 42 5 46 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 13:50:00 9 1.8 12.6 6.8 7.9 0.2 8.4 7.6 0.4 0 0.4 0.4 41 4 41 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 14:00:00 11.2 0.8 13 8.8 8 0.1 8.4 7.6 0.4 0 0.4 0.4 41 4 39 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 14:10:00 10.5 1.7 13.7 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 38 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 14:20:00 10 2.1 13.7 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 5 41 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 14:30:00 12.2 0.8 14.9 9.9 8.2 0.8 13.3 7.6 0.4 0 0.4 0.4 45 4 55 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 14:40:00 13.1 0.8 15.3 11.1 13 0.9 14.9 10.3 0.4 0 0.4 0.4 45 4 37 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 14:50:00 12.1 1.1 14.9 9.5 10.4 2.4 14.9 7.6 0.4 0 0.4 0.4 45 5 41 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 15:00:00 7.9 1.2 12.2 6.8 7.8 0.2 8.4 6.8 0.4 0 0.4 0.4 47 6 52 305 9 0 9 0 -16.9 0 -16.7 -16.9 01/15/2005 15:10:00 7.5 0.6 11.5 6.8 7.7 0.4 8 6.5 0.4 0 0.4 0.4 46 6 42 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 15:20:00 8.1 1.3 12.6 6.8 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 45 6 50 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 15:30:00 8.9 1.7 13 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 40 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 15:40:00 11.6 1.3 13.7 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 42 4 41 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 15:50:00 11.3 1 14.1 9.1 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 36 305 9 0 9 0 -16.9 0 -16.9 -16.9 01/15/2005 16:00:00 10.1 1.7 13 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 4 54 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 16:10:00 11.7 0.8 13.3 9.1 8 0.1 8.4 7.6 0.4 0 0.4 0.4 43 3 43 305 9 0 9 0 -16.9 0 -16.6 -16.9 01/15/2005 16:20:00 11.2 1 13.3 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 4 45 305 9 0 9 0 -16.7 0.1 -16.6 -16.9 01/15/2005 16:30:00 8.7 1.5 12.2 7.2 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 47 5 42 305 9 0 9 0 -16.7 0 -16.6 -16.9 01/15/2005 16:40:00 10.6 1.7 14.9 7.2 8 0.1 8.4 7.2 0.4 0 0.4 0.4 48 5 49 305 9 0 9 0 -16.5 0 -16.4 -16.7 01/15/2005 16:50:00 11.4 1.4 14.1 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 54 305 9 0 9 0 -16.4 0 -16.2 -16.6 01/15/2005 17:00:00 10.2 1.7 13 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 45 305 9 0 9 0 -16.4 0 -16.2 -16.6 01/15/2005 17:10:00 10.6 1.6 13 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 4 51 305 9 0 9 0 -16.3 0 -16 -16.6 01/15/2005 17:20:00 10.3 1.7 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 49 305 9 0 9 0 -16.3 0 -16 -16.6 01/15/2005 17:30:00 10.2 1.5 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 51 5 51 305 9 0 9 0 -16.3 0 -16 -16.4 01/15/2005 17:40:00 10.4 1.5 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 5 50 305 9 0 9 0 -16.3 0 -16 -16.4 01/15/2005 17:50:00 10.9 1.9 14.1 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 5 45 305 9 0 9 0 -16.2 0.1 -16 -16.4 01/15/2005 18:00:00 10.9 1.5 13.7 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 44 305 9 0 9 0 -16.1 0 -15.8 -16.4 01/15/2005 18:10:00 9.2 2 13.3 6.8 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 49 6 53 305 9 0 9 0 -16.1 0 -15.8 -16.4 01/15/2005 18:20:00 8.3 1.4 12.2 7.2 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 52 6 48 305 10 0 9 0 -16 0 -15.8 -16.2 01/15/2005 18:30:00 10.2 1.9 14.1 7.2 8 0.1 8.4 7.2 0.4 0 0.4 0.4 53 5 48 305 10 0 9 0 -16 0 -15.8 -16.2 01/15/2005 18:40:00 12.1 1 14.9 9.5 8 0.1 8.4 7.6 0.4 0 0.4 0.4 52 5 46 305 10 0 10 0 -15.9 0 -15.6 -16.2 01/15/2005 18:50:00 12.4 1 14.9 9.5 8.3 1.1 13.7 7.6 0.4 0 0.4 0.4 52 5 43 305 10 0 10 0 -15.9 0 -15.6 -16 01/15/2005 19:00:00 12.8 0.9 14.9 9.9 12.8 1.1 14.9 10.3 0.4 0 0.4 0.4 50 4 46 305 10 0 10 0 -15.8 0 -15.6 -16 01/15/2005 19:10:00 12.9 1.1 15.3 9.9 12.5 1.8 15.3 7.6 0.4 0 0.4 0.4 50 4 47 305 10 0 10 0 -15.8 0 -15.6 -16 01/15/2005 19:20:00 11.3 1.4 14.5 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 54 5 46 305 10 0 10 0 -15.8 0 -15.6 -16 01/15/2005 19:30:00 11.5 1 14.5 8.8 8 0.1 8.4 7.6 0.4 0 0.4 0.4 53 5 52 305 10 0 10 0 -15.8 0 -15.6 -15.8 01/15/2005 19:40:00 11.7 0.8 13.3 9.5 8 0.1 8.4 7.6 0.4 0 0.4 0.4 53 5 42 305 10 0 10 0 -15.7 0 -15.6 -15.8 01/15/2005 19:50:00 12.4 0.7 14.9 9.9 8 0.1 8.4 7.6 0.4 0 0.4 0.4 50 5 41 305 10 0 10 0 -15.7 0 -15.6 -15.8 01/15/2005 20:00:00 12.6 0.9 14.9 9.5 8.4 1.2 13.7 7.6 0.4 0 0.4 0.4 51 4 51 305 10 0 11 0 -15.6 0 -15.2 -15.8 01/15/2005 20:10:00 12.8 1 14.9 10.3 11.9 2.3 15.3 7.6 0.4 0 0.4 0.4 53 4 51 305 11 0 11 0 -15.5 0 -15.2 -15.6 01/15/2005 20:20:00 13.4 0.8 15.6 11.5 13.3 0.9 16.1 11.1 0.4 0 0.4 0.4 52 4 52 305 11 0 11 0 -15.3 0 -15 -15.6 01/15/2005 20:30:00 13.6 0.9 16.1 10.7 13.6 1 16.1 10.7 0.4 0 0.4 0.4 51 4 43 305 11 0 11 0 -15.3 0 -15 -15.4 01/15/2005 20:40:00 14 0.8 16.1 11.8 14 0.9 16.4 11.5 0.4 0 0.4 0.4 50 4 48 305 11 0 11 0 -15.2 0 -15 -15.2 01/15/2005 20:50:00 13.5 0.9 16.4 11.1 13.4 1 16.4 10.7 0.4 0 0.4 0.4 48 4 44 305 11 0 11 0 -15.2 0 -14.8 -15.2 01/15/2005 21:00:00 13 1 15.3 10.7 12.9 1.1 15.3 10.3 0.4 0 0.4 0.4 49 5 45 305 11 0 11 0 -15.1 0 -14.6 -15.2 01/15/2005 21:10:00 12.8 0.9 14.9 10.7 12.8 1 15.3 10.3 0.4 0 0.4 0.4 49 4 50 305 11 0 11 0 -15 0 -14.6 -15 01/15/2005 21:20:00 12.5 0.9 14.9 10.3 8.2 0.8 13 7.6 0.4 0 0.4 0.4 50 4 46 305 11 0 11 0 -14.8 0 -14.6 -15 01/15/2005 21:30:00 11.2 1.3 13.7 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 51 305 11 0 11 0 -14.8 0 -14.6 -15 01/15/2005 21:40:00 10.5 1.8 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 43 305 11 0 11 0 -14.8 0 -14.4 -15 01/15/2005 21:50:00 11.5 1.1 14.1 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 4 46 305 11 0 11 0 -14.7 0 -14.4 -14.8 01/15/2005 22:00:00 11.4 0.8 13.7 8.8 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 5 41 305 11 0 11 0 -14.7 0 -14.4 -14.8 01/15/2005 22:10:00 11.8 0.8 13.7 9.5 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 4 40 305 11 0 11 0 -14.6 0 -14.3 -14.8 01/15/2005 22:20:00 10.6 1.8 14.5 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 4 48 305 11 0 12 0 -14.7 0 -14.3 -14.6 01/15/2005 22:30:00 11.8 0.8 13.7 9.5 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 4 51 305 11 0 11 0 -14.6 0 -14.3 -14.6 01/15/2005 22:40:00 11.5 1.1 14.1 9.1 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 46 305 11 0 12 0 -14.6 0.1 -14.3 -14.6 01/15/2005 22:50:00 9.5 1.5 12.2 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 48 305 12 0 12 0 -14.5 0 -14.3 -14.6 01/15/2005 23:00:00 9.9 2 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 44 305 12 0 12 0 -14.5 0 -14.3 -14.6 01/15/2005 23:10:00 8.6 1.6 12.6 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 49 305 12 0 12 0 -14.4 0 -14.3 -14.6 01/15/2005 23:20:00 11 1.5 14.1 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 42 305 12 0 11 0 -14.4 0 -14.1 -14.6 01/15/2005 23:30:00 12.1 1.2 14.5 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 42 305 12 0 11 0 -14.4 0 -14.1 -14.6 01/15/2005 23:40:00 12.6 0.9 14.5 10.3 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 4 38 305 12 0 12 0 -14.4 0 -14.3 -14.4 01/15/2005 23:50:00 12.1 1.2 14.1 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 49 305 12 0 12 0 -14.3 0 -14.3 -14.4 01/16/2005 00:00:00 11.8 1.3 14.5 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 5 50 305 12 0 11 0 -14.3 0 -14.1 -14.4 01/16/2005 00:10:00 10.8 2 14.1 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 42 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/16/2005 00:20:00 11.7 1.3 14.1 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 4 43 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/16/2005 00:30:00 10.5 2 13.7 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 4 45 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/16/2005 00:40:00 10 2 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 50 305 12 0 12 0 -14.1 0.1 -13.7 -14.3 01/16/2005 00:50:00 10.1 1.8 13 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 48 305 12 0 12 0 -14 0.1 -13.7 -14.3 01/16/2005 01:00:00 10.6 1.7 13.3 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 50 305 12 0 12 0 -14 0.1 -13.7 -14.3 01/16/2005 01:10:00 10.7 1.5 13.3 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 46 305 12 0 12 0 -14 0.1 -13.7 -14.3 01/16/2005 01:20:00 11.3 1.3 14.1 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 46 305 12 0 12 0 -14.1 0.1 -13.7 -14.3 01/16/2005 01:30:00 11.8 0.9 14.1 9.5 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 5 46 305 12 0 12 0 -14 0.1 -13.7 -14.3 01/16/2005 01:40:00 10.1 2.1 14.9 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 40 305 12 0 12 0 -14 0.1 -13.7 -14.3 01/16/2005 01:50:00 10.6 1.7 14.5 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 6 50 305 12 0 12 0 -14 0.1 -13.7 -14.3 01/16/2005 02:00:00 9.1 1.7 13 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 6 45 305 12 0 12 0 -13.9 0 -13.7 -14.1 01/16/2005 02:10:00 10.3 2.1 14.1 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 5 46 305 12 0 12 0 -13.9 0 -13.7 -14.1 01/16/2005 02:20:00 9.5 1.8 13 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 5 41 305 12 0 12 0 -14 0.1 -13.7 -14.3 01/16/2005 02:30:00 9.3 2 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 47 305 12 0 12 0 -14.2 0 -13.7 -14.3 01/16/2005 02:40:00 10.4 1.9 13.7 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 43 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/16/2005 02:50:00 10.8 1.6 13.7 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 45 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/16/2005 03:00:00 8.3 1.3 13 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 5 54 305 12 0 12 0 -14.2 0 -13.7 -14.3 01/16/2005 03:10:00 8.7 1.5 13.3 7.2 8 0.2 8.4 7.2 0.4 0 0.4 0.4 46 5 39 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/16/2005 03:20:00 10.1 1.8 13.3 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 44 5 39 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/16/2005 03:30:00 10.8 1.8 13.7 7.2 8 0.2 8.4 7.6 0.4 0 0.4 0.4 43 5 39 305 12 0 12 0 -14.2 0 -14.1 -14.3 01/16/2005 03:40:00 10.5 2.2 13.7 7.2 8 0.2 8.4 7.2 0.4 0 0.4 0.4 43 5 39 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/16/2005 03:50:00 8.7 1.6 13.3 7.2 8 0.1 8.4 7.2 0.4 0 0.4 0.4 41 5 35 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/16/2005 04:00:00 11.8 1.5 14.1 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 40 5 43 305 12 0 12 0 -14.1 0 -13.7 -14.3 01/16/2005 04:10:00 11.9 0.9 14.5 9.5 8 0.1 8.4 7.6 0.4 0 0.4 0.4 41 4 43 305 12 0 12 0 -14.1 0 -13.7 -14.3 01/16/2005 04:20:00 10.5 1.9 14.1 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 43 4 46 305 12 0 12 0 -14.1 0.1 -13.7 -14.3 01/16/2005 04:30:00 12.3 0.9 14.5 9.9 8 0.1 8.4 7.6 0.4 0 0.4 0.4 43 5 38 305 12 0 12 0 -14.1 0.1 -13.7 -14.3 01/16/2005 04:40:00 11.5 1.3 14.1 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 39 305 12 0 12 0 -14 0.1 -13.7 -14.3 01/16/2005 04:50:00 11.8 1.5 14.5 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 5 46 305 12 0 12 0 -14 0 -13.7 -14.3 01/16/2005 05:00:00 11.9 1 13.7 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 45 4 44 305 12 0 12 0 -13.9 0.1 -13.7 -14.1 01/16/2005 05:10:00 11.8 0.9 13.7 9.1 8 0.1 8.4 7.6 0.4 0 0.4 0.4 46 5 46 305 13 0 13 0 -13.9 0 -13.7 -14.1 01/16/2005 05:20:00 10.6 1.8 13.7 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 5 45 305 13 0 13 0 -13.8 0 -13.7 -14.1 01/16/2005 05:30:00 11.9 0.9 13.7 9.5 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 4 46 305 13 0 13 0 -13.8 0 -13.5 -14.1 01/16/2005 05:40:00 10.2 1.6 13 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 48 4 48 305 13 0 13 0 -13.8 0 -13.5 -13.9 01/16/2005 05:50:00 10.2 1.8 13.3 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 4 48 305 13 0 13 0 -13.7 0 -13.3 -13.7 01/16/2005 06:00:00 9.6 1.7 12.6 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 50 4 48 305 13 0 13 0 -13.6 0 -13.3 -13.7 01/16/2005 06:10:00 7.8 0.2 8 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 50 4 49 305 13 0 13 0 -13.6 0 -13.3 -13.7 01/16/2005 06:20:00 7.9 0.5 11.8 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 51 5 50 305 13 0 13 0 -13.6 0 -13.3 -13.7 01/16/2005 06:30:00 7.8 0.2 8 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 50 4 53 305 13 0 13 0 -13.6 0 -13.3 -13.7 01/16/2005 06:40:00 7.8 0.2 8.4 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 4 44 305 13 0 13 0 -13.5 0 -13.1 -13.7 01/16/2005 06:50:00 8.4 1.3 12.6 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 4 42 305 14 0 14 0 -13.4 0 -13.1 -13.5 01/16/2005 07:00:00 8.5 1.5 13 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 47 4 47 305 14 0 14 0 -13.3 0 -12.9 -13.5 01/16/2005 07:10:00 10.8 1.5 13.7 7.6 8 0.1 8.4 8 0.4 0 0.4 0.4 48 5 48 305 14 0 14 0 -13.3 0 -13.1 -13.5 01/16/2005 07:20:00 11.4 1.4 13.3 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 49 4 44 305 14 0 14 0 -13.3 0 -12.9 -13.5 01/16/2005 07:30:00 11.8 0.8 13.3 9.9 8.1 0.1 8.4 8 0.4 0 0.4 0.4 49 4 46 305 14 0 14 0 -13.2 0 -12.9 -13.3 01/16/2005 07:40:00 11.3 0.8 12.6 7.6 8 0.1 8.4 8 0.4 0 0.4 0.4 50 4 54 305 14 0 14 0 -13.2 0 -12.9 -13.3 01/16/2005 07:50:00 11.3 0.9 13.3 8 8 0.1 8.4 7.6 0.4 0 0.4 0.4 50 5 46 305 14 0 14 0 -13.1 0 -12.9 -13.3 01/16/2005 08:00:00 10.4 1.5 13 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 53 4 50 305 15 0 15 0 -12.9 0 -12.5 -13.1 01/16/2005 08:10:00 11.5 0.8 13.3 9.5 8.1 0.1 8.4 8 0.4 0 0.4 0.4 54 4 53 305 15 0 15 0 -12.8 0 -12.5 -12.9 01/16/2005 08:20:00 10.3 1.5 12.6 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 53 5 58 305 15 0 15 0 -12.8 0 -12.5 -12.9 01/16/2005 08:30:00 10.7 1.7 14.5 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 54 5 53 305 15 0 15 0 -12.7 0 -12.5 -12.9 01/16/2005 08:40:00 9.8 1.7 13.3 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 56 5 49 305 15 0 15 0 -12.7 0 -12.5 -12.9 01/16/2005 08:50:00 8.2 1.2 13 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 58 5 54 305 15 0 15 0 -12.6 0 -12.3 -12.7 01/16/2005 09:00:00 10 1.9 13.3 7.6 8 0.1 8.4 7.6 0.4 0 0.4 0.4 58 5 57 305 15 0 15 0 -12.6 0 -12.3 -12.7 01/16/2005 09:10:00 10.4 1.8 13.3 7.6 8.1 0.1 8.4 7.6 0.4 0 0.4 0.4 59 5 61 305 15 0 15 0 -12.6 0 -12.3 -12.9 01/16/2005 09:20:00 10.5 1.7 13.7 7.6 8.1 0.1 8.4 8 0.4 0 0.4 0.4 59 4 56 305 15 0 15 0 -12.5 0 -12.3 -12.7 01/16/2005 09:30:00 11.5 0.8 13.3 9.5 8.1 0.1 8.4 8 0.4 0 0.4 0.4 57 4 57 305 16 0 15 0 -12.5 0 -12.1 -12.7 01/16/2005 09:40:00 10.7 1.6 13 7.6 8.1 0.1 8.4 7.6 0.4 0 0.4 0.4 57 5 53 305 16 0 16 0 -12.5 0 -12.3 -12.5 01/16/2005 09:50:00 9.1 1.7 13.3 7.6 8.1 0.1 8.4 8 0.4 0 0.4 0.4 58 4 62 305 16 0 15 0 -12.5 0.1 -12.1 -12.5 01/16/2005 10:00:00 11.7 0.8 14.1 9.9 8.1 0.1 8.4 8 0.4 0 0.4 0.4 57 4 59 305 16 0 16 0 -12.4 0.1 -12.1 -12.5 01/16/2005 10:10:00 10.8 1.5 13.7 7.6 8.1 0.1 8.4 8 0.4 0 0.4 0.4 57 4 57 305 16 0 15 0 -12.3 0.1 -12.1 -12.5 01/16/2005 10:20:00 8.5 1.3 12.6 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 58 5 64 305 16 0 16 0 -12.4 0.1 -12.1 -12.5 01/16/2005 10:30:00 8.8 1.4 12.6 7.2 8 0.1 8.4 7.6 0.4 0 0.4 0.4 57 5 51 305 16 0 15 0 -12.5 0 -12.1 -12.5 01/16/2005 10:40:00 8.5 1.3 12.6 7.6 8.1 0.1 8.4 8 0.4 0 0.4 0.4 59 4 61 305 15 0 15 0 -12.5 0 -12.3 -12.7 01/16/2005 10:50:00 8.2 1 12.2 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 61 4 63 305 15 0 15 0 -12.5 0 -12.3 -12.7 01/16/2005 11:00:00 11 0.5 12.2 9.5 8.1 0.2 8.4 8 0.4 0 0.4 0.4 59 3 61 305 15 0 15 0 -12.6 0 -12.3 -12.7 01/16/2005 11:10:00 11.6 0.6 13.3 9.9 8.1 0.2 8.4 8 0.4 0 0.4 0.4 59 3 59 305 15 0 15 0 -12.6 0 -12.3 -12.7 01/16/2005 11:20:00 11.5 0.6 13 9.9 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 61 4 58 305 15 0 15 0 -12.6 0 -12.3 -12.7 01/16/2005 11:30:00 10.4 1.5 13 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 59 3 55 305 15 0 15 0 -12.5 0 -12.3 -12.5 01/16/2005 11:40:00 7.9 0.2 8.4 7.6 8.1 0.1 8.4 7.6 0.4 0 0.4 0.4 59 3 57 305 15 0 15 0 -12.5 0 -12.3 -12.7 01/16/2005 11:50:00 8 0.2 8.4 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 59 3 59 305 15 0 15 0 -12.4 0 -12.1 -12.5 01/16/2005 12:00:00 8.1 0.4 11.5 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 59 4 57 305 16 0 15 0 -12.3 0 -12.1 -12.5 01/16/2005 12:10:00 8.1 0.5 11.8 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 60 3 54 305 16 0 15 0 -12.3 0 -12.1 -12.5 01/16/2005 12:20:00 10.8 0.5 12.2 9.5 8.1 0.2 8.4 8 0.4 0 0.4 0.4 60 4 58 305 16 0 15 0 -12.3 0 -12.1 -12.5 01/16/2005 12:30:00 10.8 1 12.6 8 8.1 0.2 8.4 8 0.4 0 0.4 0.4 59 3 58 305 16 0 15 0 -12.2 0 -12.1 -12.5 01/16/2005 12:40:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 59 4 62 305 16 0 16 0 -12.1 0 -11.9 -12.3 01/16/2005 12:50:00 8 0.2 8.4 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 60 4 60 305 16 0 16 0 -12.1 0 -11.9 -12.3 01/16/2005 13:00:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 57 3 62 305 16 0 16 0 -12.1 0 -11.9 -12.3 01/16/2005 13:10:00 8.1 0.3 9.9 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 58 4 52 305 16 0 16 0 -12.1 0 -11.9 -12.3 01/16/2005 13:20:00 8 0.2 8.4 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 60 3 58 305 16 0 16 0 -12 0 -11.7 -12.3 01/16/2005 13:30:00 8 0.2 8.4 7.2 8.1 0.1 8.4 7.6 0.4 0 0.4 0.4 59 4 59 305 16 0 16 0 -12 0 -11.7 -12.1 01/16/2005 13:40:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 59 3 57 305 16 0 16 0 -12 0 -11.7 -12.1 01/16/2005 13:50:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 58 4 54 305 17 0 16 0 -12 0 -11.7 -12.1 01/16/2005 14:00:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 57 4 57 305 16 0 16 0 -12 0 -11.7 -12.1 01/16/2005 14:10:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 54 4 56 305 16 0 16 0 -12.1 0 -11.9 -12.3 01/16/2005 14:20:00 8 0.2 8.4 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 54 3 46 305 16 0 16 0 -12.1 0 -11.7 -12.3 01/16/2005 14:30:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 56 4 51 305 16 0 16 0 -12 0 -11.7 -12.1 01/16/2005 14:40:00 7.9 0.2 8.4 7.2 8 0.2 8.4 7.2 0.4 0 0.4 0.4 54 5 61 305 17 0 16 0 -11.9 0 -11.7 -12.1 01/16/2005 14:50:00 7.9 0.3 8.4 7.2 8 0.2 8.4 7.2 0.4 0 0.4 0.4 52 4 56 305 17 0 17 0 -11.9 0 -11.7 -12.1 01/16/2005 15:00:00 8 0.2 8.4 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 52 3 56 305 17 0 17 0 -12 0 -11.7 -12.1 01/16/2005 15:10:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 54 4 47 305 17 0 17 0 -11.9 0.1 -11.7 -12.1 01/16/2005 15:20:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 57 3 58 305 17 0 17 0 -11.7 0 -11.5 -12.1 01/16/2005 15:30:00 8.1 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 57 3 53 305 17 0 17 0 -11.7 0 -11.5 -11.9 01/16/2005 15:40:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 59 4 54 305 17 0 17 0 -11.7 0 -11.3 -11.9 01/16/2005 15:50:00 8.1 0.2 8.4 8 8.1 0.2 8.4 8 0.4 0 0.4 0.4 61 3 61 305 17 0 17 0 -11.6 0 -11.5 -11.7 01/16/2005 16:00:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 61 3 62 305 17 0 15 0 -11.5 0 -11.3 -11.7 01/16/2005 16:10:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 63 3 62 305 17 0 18 0 -11.5 0 -11.3 -11.7 01/16/2005 16:20:00 8.2 0.2 8.4 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 64 3 66 305 17 0 17 0 -11.5 0 -11.3 -11.7 01/16/2005 16:30:00 8.2 0.2 8.4 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 64 3 63 305 18 0 18 0 -11.5 0 -11.3 -11.7 01/16/2005 16:40:00 8.2 0.2 8.4 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 63 2 70 305 18 0 18 0 -11.5 0 -11.3 -11.7 01/16/2005 16:50:00 8.2 0.2 8.4 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 64 3 62 305 17 0 17 0 -11.6 0 -11.3 -11.7 01/16/2005 17:00:00 8.1 0.2 8.4 8 8.1 0.2 8.4 8 0.4 0 0.4 0.4 63 3 62 305 17 0 17 0 -11.6 0 -11.3 -11.7 01/16/2005 17:10:00 8 0.2 8.4 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 61 4 60 305 18 0 18 0 -11.5 0 -11.3 -11.7 01/16/2005 17:20:00 8 0.3 8.4 7.2 8 0.2 8.4 7.2 0.4 0 0.4 0.4 58 3 61 305 18 0 17 0 -11.5 0 -11.3 -11.7 01/16/2005 17:30:00 8.1 0.2 8.4 7.2 8.1 0.2 8.4 7.2 0.4 0 0.4 0.4 57 3 59 305 18 0 18 0 -11.5 0 -11.3 -11.5 01/16/2005 17:40:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 56 4 59 305 18 0 18 0 -11.4 0 -11.3 -11.5 01/16/2005 17:50:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 52 4 59 305 18 0 18 0 -11.4 0 -11.3 -11.5 01/16/2005 18:00:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 52 4 54 305 18 0 18 0 -11.4 0.1 -11.1 -11.5 01/16/2005 18:10:00 8.1 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 53 4 49 305 18 0 18 0 -11.5 0 -11.3 -11.7 01/16/2005 18:20:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 54 4 57 305 17 0 18 0 -11.6 0 -11.3 -11.7 01/16/2005 18:30:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 54 3 49 305 17 0 18 0 -11.6 0 -11.3 -11.7 01/16/2005 18:40:00 7.9 0.3 8.4 7.2 8 0.3 8.4 6.8 0.4 0 0.4 0.4 53 4 59 305 17 0 18 0 -11.7 0 -11.5 -11.9 01/16/2005 18:50:00 7.7 0.3 8.4 6.8 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 53 4 49 305 17 0 17 0 -11.6 0 -11.3 -11.9 01/16/2005 19:00:00 7.9 0.2 8.4 7.2 8 0.2 8.4 7.2 0.4 0 0.4 0.4 56 4 57 305 17 0 17 0 -11.5 0 -11.3 -11.7 01/16/2005 19:10:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.2 0.4 0 0.4 0.4 61 3 59 305 18 0 18 0 -11.4 0 -11.1 -11.7 01/16/2005 19:20:00 8 0.2 8.4 7.2 8 0.2 8.4 7.2 0.4 0 0.4 0.4 60 4 66 305 18 0 18 0 -11.4 0 -11.1 -11.5 01/16/2005 19:30:00 7.9 0.3 8.4 6.8 8 0.3 8.4 6.8 0.4 0 0.4 0.4 56 3 57 305 18 0 18 0 -11.4 0 -11.1 -11.7 01/16/2005 19:40:00 7.7 0.3 8.4 6.8 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 50 5 57 305 17 0 18 0 -11.5 0 -11.3 -11.9 01/16/2005 19:50:00 7.9 0.2 8.4 7.2 8 0.3 8.4 6.8 0.4 0 0.4 0.4 47 3 48 305 17 0 17 0 -11.8 0 -11.5 -12.1 01/16/2005 20:00:00 8 0.2 8.4 7.2 8 0.2 8.4 7.6 0.4 0 0.4 0.4 48 3 48 305 17 0 17 0 -11.8 0.1 -11.7 -12.1 01/16/2005 20:10:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 49 3 50 305 17 0 17 0 -12 0 -11.7 -12.1 01/16/2005 20:20:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.2 0.4 0 0.4 0.4 52 3 51 305 17 0 17 0 -12 0 -11.7 -12.1 01/16/2005 20:30:00 8 0.2 8.4 7.2 8 0.2 8.4 7.2 0.4 0 0.4 0.4 52 4 51 305 17 0 17 0 -12 0 -11.7 -12.1 01/16/2005 20:40:00 7.9 0.3 8.4 7.2 7.9 0.3 8.4 7.2 0.4 0 0.4 0.4 52 4 45 305 17 0 17 0 -12 0 -11.7 -12.1 01/16/2005 20:50:00 7.7 0.3 8.4 6.8 7.8 0.4 8.4 6.5 0.4 0 0.4 0.4 50 4 47 305 16 0 16 0 -12 0 -11.7 -12.1 01/16/2005 21:00:00 7.9 0.2 8.4 7.2 8 0.2 8.4 6.8 0.4 0 0.4 0.4 51 3 49 305 16 0 16 0 -12.1 0 -11.9 -12.3 01/16/2005 21:10:00 7.7 0.2 8.4 7.2 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 55 4 52 305 16 0 16 0 -12.2 0 -11.9 -12.5 01/16/2005 21:20:00 7.8 0.3 8.4 7.2 7.8 0.3 8.4 6.8 0.4 0 0.4 0.4 60 4 56 305 16 0 16 0 -12.3 0 -12.1 -12.5 01/16/2005 21:30:00 8.1 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 60 3 62 305 16 0 16 0 -12.2 0 -12.1 -12.5 01/16/2005 21:40:00 8 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 59 3 62 305 16 0 16 0 -12.3 0.1 -12.1 -12.5 01/16/2005 21:50:00 8.1 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 59 4 58 305 16 0 16 0 -12.5 0 -12.1 -12.5 01/16/2005 22:00:00 7.8 0.3 8.4 7.2 7.9 0.2 8.4 7.2 0.4 0 0.4 0.4 59 4 59 305 16 0 16 0 -12.5 0 -12.3 -12.5 01/16/2005 22:10:00 7.9 0.3 8.4 6.8 7.9 0.3 8.4 6.8 0.4 0 0.4 0.4 57 5 62 305 15 0 15 0 -12.6 0 -12.3 -12.7 01/16/2005 22:20:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 59 3 64 305 15 0 15 0 -12.7 0 -12.5 -12.9 01/16/2005 22:30:00 8.2 0.2 8.4 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 60 3 57 305 15 0 15 0 -12.6 0 -12.5 -12.9 01/16/2005 22:40:00 8.2 0.2 8.4 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 61 3 62 305 15 0 15 0 -12.6 0 -12.5 -12.9 01/16/2005 22:50:00 8.2 0.2 8.4 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 60 3 59 305 15 0 15 0 -12.7 0 -12.5 -12.9 01/16/2005 23:00:00 8.2 0.2 8.4 7.6 8.2 0.2 8.4 8 0.4 0 0.4 0.4 58 3 60 305 15 0 15 0 -12.9 0.1 -12.7 -13.1 01/16/2005 23:10:00 8.2 0.2 8.4 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 59 3 58 305 15 0 15 0 -12.9 0 -12.5 -13.1 01/16/2005 23:20:00 8.2 0.2 8.4 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 59 3 63 305 15 0 15 0 -12.8 0 -12.5 -12.9 01/16/2005 23:30:00 8.2 0.2 8.4 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 61 2 61 305 15 0 15 0 -12.8 0 -12.5 -12.9 01/16/2005 23:40:00 12.2 1 13.3 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 62 2 63 305 15 0 15 0 -12.7 0 -12.5 -12.9 01/16/2005 23:50:00 12.3 0.6 13.7 10.7 8.2 0.2 8.4 8 0.4 0 0.4 0.4 62 2 62 305 15 0 15 0 -12.7 0 -12.5 -12.9 01/17/2005 00:00:00 8.7 1.2 12.6 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 62 3 59 305 15 0 14 0 -12.6 0 -12.5 -12.9 01/17/2005 00:10:00 9.1 1.7 13.3 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 65 3 64 305 15 0 15 0 -12.5 0 -12.1 -12.7 01/17/2005 00:20:00 12.5 0.5 14.1 11.5 8.2 0.2 8.4 8 0.4 0 0.4 0.4 66 2 63 305 15 0 15 0 -12.3 0.1 -12.1 -12.5 01/17/2005 00:30:00 14.2 0.6 15.6 13 12.5 3.2 16.4 8 0.4 0 0.4 0.4 69 3 67 305 15 0 15 0 -12.2 0 -12.1 -12.5 01/17/2005 00:40:00 14.6 0.6 16.4 12.6 15 0.7 17.2 13 0.4 0 0.4 0.4 72 3 77 305 15 0 15 0 -12.2 0 -11.9 -12.3 01/17/2005 00:50:00 13.9 0.8 15.6 11.8 14.4 0.9 16.4 11.5 0.4 0 0.4 0.4 72 3 77 305 15 0 15 0 -12.2 0 -11.9 -12.3 01/17/2005 01:00:00 11.7 0.8 13.7 9.5 12 1.2 14.5 8 0.4 0 0.4 0.4 67 3 70 305 14 0 14 0 -12.4 0.1 -12.1 -12.5 01/17/2005 01:10:00 8.4 0.6 11.5 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 64 4 67 305 14 0 14 0 -12.6 0 -12.3 -12.7 01/17/2005 01:20:00 8.1 0.2 8.4 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 61 4 64 305 14 0 14 0 -12.6 0 -12.5 -12.7 01/17/2005 01:30:00 7.9 0.3 8.4 6.8 8 0.3 8.4 6.1 0.4 0 0.4 0.4 60 4 62 305 14 0 14 0 -12.6 0 -12.5 -12.7 01/17/2005 01:40:00 8.1 0.2 8.4 7.2 8.1 0.2 8.4 7.2 0.4 0 0.4 0.4 63 5 57 305 14 0 14 0 -12.5 0 -12.1 -12.7 01/17/2005 01:50:00 8.1 0.4 11.5 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 68 7 78 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/17/2005 02:00:00 8.1 0.5 12.2 6.8 8 0.3 8.4 6.8 0.4 0 0.4 0.4 69 8 71 305 14 0 14 0 -12.2 0 -12.1 -12.5 01/17/2005 02:10:00 8.6 1.1 13.3 7.6 8.1 0.2 8.4 7.2 0.4 0 0.4 0.4 71 7 82 305 14 0 14 0 -12.2 0 -11.9 -12.5 01/17/2005 02:20:00 8.8 1.3 14.5 7.6 8.3 0.8 15.3 7.2 0.4 0 0.4 0.4 72 6 84 305 14 0 14 0 -12.2 0 -11.9 -12.3 01/17/2005 02:30:00 8.6 1.1 13.3 7.6 8.2 0.2 8.4 8 0.4 0 0.4 0.4 69 6 70 305 14 0 14 0 -12.1 0 -11.9 -12.3 01/17/2005 02:40:00 8.4 0.9 12.6 7.6 8.2 0.2 8.4 7.6 0.4 0 0.4 0.4 65 6 71 305 14 0 14 0 -12 0 -11.7 -12.3 01/17/2005 02:50:00 7.8 0.5 8.4 5.3 7.9 0.5 8.4 4.6 0.4 0 0.4 0.4 61 5 66 305 14 0 14 0 -12.1 0 -11.7 -12.3 01/17/2005 03:00:00 7.6 0.5 8.4 5.7 7.5 0.7 8.4 4.6 0.4 0 0.4 0.4 55 6 57 305 14 0 14 0 -12.2 0 -11.9 -12.5 01/17/2005 03:10:00 8.1 0.2 8.4 7.2 8.1 0.3 8.4 6.5 0.4 0 0.4 0.4 59 4 57 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/17/2005 03:20:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 62 4 65 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/17/2005 03:30:00 8.2 0.2 8.4 7.6 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 61 4 58 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/17/2005 03:40:00 8.1 0.2 8.4 7.6 8.1 0.2 8.4 8 0.4 0 0.4 0.4 62 4 64 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/17/2005 03:50:00 8.1 0.2 8.8 7.2 8.1 0.2 8.4 7.6 0.4 0 0.4 0.4 62 4 60 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/17/2005 04:00:00 8.7 1.3 13 7.6 8.2 0.2 8.8 7.6 0.4 0 0.4 0.4 62 4 65 305 14 0 14 0 -12.2 0 -12.1 -12.5 01/17/2005 04:10:00 9.1 1.5 12.6 7.6 8.2 0.2 8.4 8 0.4 0 0.4 0.4 63 4 64 305 14 0 14 0 -12.2 0 -12.1 -12.5 01/17/2005 04:20:00 8.1 0.5 11.8 6.8 8.1 0.3 8.4 7.2 0.4 0 0.4 0.4 60 6 65 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/17/2005 04:30:00 6.8 1 8.4 3.4 6.8 1 8.4 3.8 0.4 0 0.4 0.4 53 9 65 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/17/2005 04:40:00 6.8 0.8 8.4 4.9 6.9 0.8 8.4 4.6 0.4 0 0.4 0.4 56 7 52 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/17/2005 04:50:00 7.8 0.4 8.4 6.1 7.8 0.4 8.4 6.1 0.4 0 0.4 0.4 60 6 60 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/17/2005 05:00:00 8.2 0.2 8.8 7.2 8.2 0.2 8.4 7.2 0.4 0 0.4 0.4 65 5 64 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/17/2005 05:10:00 8.4 0.6 11.8 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 64 4 67 305 13 0 13 0 -12.3 0 -12.1 -12.5 01/17/2005 05:20:00 8.1 0.3 8.8 6.8 8.1 0.3 8.8 6.8 0.4 0 0.4 0.4 58 5 60 305 13 0 13 0 -12.4 0.1 -12.1 -12.7 01/17/2005 05:30:00 7.6 0.5 8.4 6.1 7.6 0.6 8.4 5.3 0.4 0 0.4 0.4 57 6 57 305 13 0 13 0 -12.6 0 -12.3 -12.9 01/17/2005 05:40:00 7.5 0.5 8.4 5.7 7.4 0.6 8.4 5.7 0.4 0 0.4 0.4 56 6 61 305 13 0 13 0 -12.6 0 -12.3 -12.7 01/17/2005 05:50:00 7.6 0.5 8.4 6.5 7.7 0.5 8.4 6.5 0.4 0 0.4 0.4 53 6 51 305 13 0 13 0 -12.6 0 -12.5 -12.7 01/17/2005 06:00:00 7.9 0.4 8.4 6.5 7.9 0.4 8.4 6.5 0.4 0 0.4 0.4 54 6 51 305 13 0 13 0 -12.6 0 -12.5 -12.9 01/17/2005 06:10:00 8.1 0.3 8.8 6.8 8 0.3 8.8 6.8 0.4 0 0.4 0.4 60 5 63 305 13 0 13 0 -12.6 0 -12.5 -12.9 01/17/2005 06:20:00 8.6 1 13 8 8.2 0.2 8.4 8 0.4 0 0.4 0.4 63 4 70 305 13 0 13 0 -12.5 0 -12.3 -12.7 01/17/2005 06:30:00 9.2 1.5 13 8 8.3 0.2 8.8 8 0.4 0 0.4 0.4 61 3 62 305 13 0 13 0 -12.6 0 -12.3 -12.9 01/17/2005 06:40:00 12.6 0.8 14.5 11.1 12 1.9 14.9 8 0.4 0 0.4 0.4 65 4 67 305 13 0 13 0 -12.6 0 -12.3 -12.9 01/17/2005 06:50:00 13.6 0.8 16.4 11.5 13.7 1 16.8 11.5 0.4 0 0.4 0.4 67 4 72 305 13 0 13 0 -12.5 0 -12.3 -12.5 01/17/2005 07:00:00 13.4 0.8 15.6 10.7 13.5 1.1 16.1 8 0.4 0 0.4 0.4 65 4 70 305 13 0 13 0 -12.4 0.1 -12.1 -12.5 01/17/2005 07:10:00 13.1 0.9 14.9 10.7 13 1 15.3 9.9 0.4 0 0.4 0.4 65 5 69 305 13 0 13 0 -12.3 0 -12.1 -12.5 01/17/2005 07:20:00 12.4 1.3 15.6 8 11.6 2.1 15.3 8 0.4 0 0.4 0.4 66 6 65 305 13 0 13 0 -12.3 0 -12.1 -12.5 01/17/2005 07:30:00 9.9 1.8 14.9 7.6 9.4 1.7 14.9 8 0.4 0 0.4 0.4 64 6 66 305 13 0 13 0 -12.3 0 -12.1 -12.5 01/17/2005 07:40:00 8 0.4 8.8 5.7 7.9 0.6 11.5 5.7 0.4 0 0.4 0.4 59 8 77 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 07:50:00 7.5 0.6 8.4 5.3 7.3 0.8 8.4 5.3 0.4 0 0.4 0.4 55 6 55 305 12 0 12 0 -12.5 0.1 -12.1 -12.5 01/17/2005 08:00:00 7.3 1 8.4 3.8 7.2 1.1 8.4 2.6 0.4 0 0.4 0.4 54 8 54 305 12 0 12 0 -12.4 0.1 -12.1 -12.5 01/17/2005 08:10:00 6.7 0.8 8 4.6 6.5 0.9 8 4.2 0.4 0 0.4 0.4 47 8 43 305 12 0 12 0 -12.5 0 -12.3 -12.7 01/17/2005 08:20:00 7.3 0.7 8.4 5.3 7.2 0.7 8.4 4.9 0.4 0 0.4 0.4 45 6 47 305 12 0 12 0 -12.6 0 -12.3 -12.7 01/17/2005 08:30:00 7.8 0.5 8.4 5.3 7.8 0.5 8.4 5.3 0.4 0 0.4 0.4 45 5 45 305 12 0 12 0 -12.5 0 -12.3 -12.7 01/17/2005 08:40:00 7.6 0.5 8.4 6.1 7.6 0.6 8.4 5.7 0.4 0 0.4 0.4 44 6 40 305 13 0 13 0 -12.5 0 -12.3 -12.7 01/17/2005 08:50:00 7.6 0.5 8.4 6.1 7.7 0.4 8.4 6.5 0.4 0 0.4 0.4 41 6 41 305 13 0 13 0 -12.5 0 -12.3 -12.7 01/17/2005 09:00:00 7.6 0.5 8.4 5.7 7.6 0.6 8.4 5.7 0.4 0 0.4 0.4 44 6 44 305 13 0 13 0 -12.5 0 -12.1 -12.7 01/17/2005 09:10:00 7.5 0.5 8.8 5.7 7.4 0.6 8.4 5.7 0.4 0 0.4 0.4 47 6 45 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 09:20:00 7.4 0.5 8.4 6.1 7.4 0.6 8.4 5.7 0.4 0 0.4 0.4 44 6 46 305 13 0 13 0 -12.4 0.1 -12.1 -12.5 01/17/2005 09:30:00 7.8 0.4 8.4 6.1 7.8 0.5 8.4 5.7 0.4 0 0.4 0.4 46 5 48 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 09:40:00 7.9 0.4 8.4 6.8 7.9 0.4 8.4 6.8 0.4 0 0.4 0.4 52 5 50 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 09:50:00 7.8 0.4 8.4 6.1 7.7 0.5 8.4 6.1 0.4 0 0.4 0.4 53 5 52 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 10:00:00 7.7 0.5 8.4 6.1 7.8 0.5 8.4 5.7 0.4 0 0.4 0.4 53 5 45 305 13 0 13 0 -12.5 0 -12.1 -12.7 01/17/2005 10:10:00 7.9 0.6 8.8 5.7 7.9 0.6 8.4 5.7 0.4 0 0.4 0.4 52 5 52 305 13 0 13 0 -12.5 0 -12.3 -12.7 01/17/2005 10:20:00 7.8 0.5 8.8 6.5 7.8 0.5 8.4 6.1 0.4 0 0.4 0.4 50 5 50 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 10:30:00 8.1 0.2 8.8 7.2 8.1 0.2 8.4 7.2 0.4 0 0.4 0.4 59 4 64 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 10:40:00 8.5 0.6 11.5 7.6 8.3 0.2 8.8 8 0.4 0 0.4 0.4 62 5 59 305 13 0 13 0 -12.3 0 -12.1 -12.5 01/17/2005 10:50:00 9.7 1.5 13 8 8.3 0.2 8.8 8 0.4 0 0.4 0.4 63 4 66 305 13 0 13 0 -12.2 0 -12.1 -12.3 01/17/2005 11:00:00 9.7 1.7 13.7 8 8.4 0.1 8.8 8 0.4 0 0.4 0.4 63 5 60 305 13 0 13 0 -12.1 0 -11.9 -12.3 01/17/2005 11:10:00 9.7 1.7 13.3 8 8.7 1.2 14.1 8 0.4 0 0.4 0.4 59 5 56 305 13 0 13 0 -12.2 0 -11.9 -12.5 01/17/2005 11:20:00 9.1 1.3 13.3 8 10.7 2 13.7 8 0.4 0 0.4 0.4 57 4 57 305 13 0 13 0 -12.2 0 -12.1 -12.3 01/17/2005 11:30:00 10.3 1.7 13.3 8 9 1.4 13.3 8 0.4 0 0.4 0.4 63 5 61 305 13 0 13 0 -12.2 0 -12.1 -12.5 01/17/2005 11:40:00 13.2 0.9 15.3 11.1 13.1 0.9 15.3 11.1 0.4 0 0.4 0.4 68 3 70 305 13 0 13 0 -12.3 0 -12.1 -12.5 01/17/2005 11:50:00 14.1 0.6 16.1 12.2 14.1 0.8 16.4 11.5 0.4 0 0.4 0.4 70 3 70 305 13 0 13 0 -12.3 0 -12.1 -12.5 01/17/2005 12:00:00 15 0.6 16.4 13.3 14.9 0.6 16.8 13 0.4 0 0.4 0.4 71 3 72 305 13 0 13 0 -12.4 0.1 -12.1 -12.5 01/17/2005 12:10:00 15.7 1 18.3 13.3 15.4 1 17.9 13 0.4 0 0.4 0.4 75 4 78 305 12 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 12:20:00 17.4 0.8 19.9 15.3 17.3 0.8 19.5 14.9 0.4 0 0.4 0.4 76 4 72 305 12 0 12 0 -12.5 0 -12.1 -12.5 01/17/2005 12:30:00 17.6 1.1 20.6 14.1 17.3 1.2 21 14.1 0.4 0 0.4 0.4 78 5 78 305 12 0 12 0 -12.4 0.1 -12.1 -12.5 01/17/2005 12:40:00 16.4 1 20.2 13 16.1 1.2 19.5 11.8 0.4 0 0.4 0.4 79 6 85 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 12:50:00 15.9 1 18.7 13.7 15.8 1.2 18.3 13 0.4 0 0.4 0.4 73 6 79 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 13:00:00 14.7 1 17.6 11.5 14.6 1.2 17.6 11.1 0.4 0 0.4 0.4 71 6 70 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 13:10:00 14.5 1.6 19.5 10.3 14.2 1.6 19.1 10.3 0.4 0 0.4 0.4 77 7 86 305 12 0 12 0 -12.3 0.1 -12.1 -12.5 01/17/2005 13:20:00 15.8 1.5 19.1 11.5 15.4 1.5 18.7 10.7 0.4 0 0.4 0.4 83 7 82 305 12 0 12 0 -12.4 0.1 -12.1 -12.5 01/17/2005 13:30:00 14.3 2.2 18.7 8.4 13.6 2.5 19.1 8.4 0.4 0 0.4 0.4 84 7 89 305 12 0 12 0 -12.4 0.1 -12.1 -12.5 01/17/2005 13:40:00 11.6 2.2 16.1 7.6 10.8 2.3 15.6 7.6 0.4 0 0.4 0.4 77 9 84 305 12 0 12 0 -12.4 0.1 -12.1 -12.5 01/17/2005 13:50:00 8.2 1 13 6.1 8.1 0.9 13.3 6.1 0.4 0 0.4 0.4 66 10 62 305 12 0 12 0 -12.5 0 -12.1 -12.7 01/17/2005 14:00:00 7.9 0.6 8.8 5.7 7.8 0.6 8.8 5.7 0.4 0 0.4 0.4 71 9 62 305 12 0 12 0 -12.5 0 -12.3 -12.7 01/17/2005 14:10:00 7.5 0.9 8.8 4.2 7.4 1 8.8 4.2 0.4 0 0.4 0.4 75 13 72 305 12 0 12 0 -12.6 0 -12.3 -12.7 01/17/2005 14:20:00 7.4 1.2 13 4.2 7.2 1.2 13.7 4.6 0.4 0 0.4 0.4 77 17 93 305 12 0 12 0 -12.6 0 -12.3 -12.7 01/17/2005 14:30:00 7.5 1.2 11.5 4.6 7.4 1.3 8.8 2.6 0.4 0 0.4 0.4 75 14 75 305 12 0 12 0 -12.6 0 -12.3 -12.7 01/17/2005 14:40:00 9.5 1.7 14.5 6.8 9.1 1.7 14.1 6.5 0.4 0 0.4 0.4 77 10 82 305 12 0 12 0 -12.6 0 -12.3 -12.7 01/17/2005 14:50:00 9.3 1.5 14.9 6.8 8.7 1.1 13.3 6.8 0.4 0 0.4 0.4 79 12 62 305 12 0 12 0 -12.6 0 -12.3 -12.7 01/17/2005 15:00:00 8.1 1.1 14.1 5.7 8 1.2 13.7 4.6 0.4 0 0.4 0.4 72 9 78 305 12 0 12 0 -12.5 0 -12.3 -12.5 01/17/2005 15:10:00 7.5 0.7 8.8 5.3 7.4 0.8 8.8 5.3 0.4 0 0.4 0.4 67 11 69 305 12 0 12 0 -12.5 0 -12.3 -12.5 01/17/2005 15:20:00 7.7 0.5 8.8 6.1 7.6 0.6 8.8 5.7 0.4 0 0.4 0.4 58 7 59 305 12 0 12 0 -12.5 0 -12.1 -12.5 01/17/2005 15:30:00 7.2 0.9 8.4 4.6 7.2 0.9 8.4 4.2 0.4 0 0.4 0.4 62 11 66 305 12 0 12 0 -12.6 0 -12.3 -12.7 01/17/2005 15:40:00 7.8 0.7 8.8 5.3 7.7 0.7 8.8 5.3 0.4 0 0.4 0.4 68 9 77 305 12 0 12 0 -12.6 0 -12.3 -12.7 01/17/2005 15:50:00 8.5 0.5 11.5 7.2 8.3 0.2 8.8 7.6 0.4 0 0.4 0.4 72 5 81 305 12 0 12 0 -12.6 0 -12.5 -12.7 01/17/2005 16:00:00 8.5 0.2 8.8 7.6 8.4 0.2 8.8 7.6 0.4 0 0.4 0.4 71 4 75 305 12 0 12 0 -12.6 0 -12.5 -12.7 01/17/2005 16:10:00 8.4 0.2 8.8 7.6 8.3 0.2 8.8 7.6 0.4 0 0.4 0.4 68 5 63 305 12 0 12 0 -12.6 0 -12.5 -12.7 01/17/2005 16:20:00 8.4 0.2 8.8 8 8.3 0.2 8.8 7.6 0.4 0 0.4 0.4 69 5 73 305 12 0 12 0 -12.6 0 -12.1 -12.7 01/17/2005 16:30:00 8.5 0.2 8.8 8 8.6 0.7 11.8 8 0.4 0 0.4 0.4 70 3 69 305 12 0 12 0 -12.5 0 -12.3 -12.7 01/17/2005 16:40:00 8.3 0.2 8.8 7.6 8.3 0.2 8.8 7.6 0.4 0 0.4 0.4 67 3 70 305 12 0 12 0 -12.5 0 -12.3 -12.7 01/17/2005 16:50:00 7.7 0.4 8.4 6.5 7.6 0.5 8.4 6.1 0.4 0 0.4 0.4 71 4 70 305 12 0 12 0 -12.5 0 -12.3 -12.5 01/17/2005 17:00:00 7.6 0.6 8.8 5.7 7.5 0.7 8.4 5.3 0.4 0 0.4 0.4 66 5 61 305 12 0 12 0 -12.5 0 -12.3 -12.5 01/17/2005 17:10:00 7.5 0.7 8.4 5.3 7.5 0.7 8.4 5.3 0.4 0 0.4 0.4 65 5 66 305 12 0 12 0 -12.5 0 -12.3 -12.5 01/17/2005 17:20:00 8.1 0.4 8.8 6.1 8.1 0.4 8.8 6.8 0.4 0 0.4 0.4 61 6 56 305 12 0 12 0 -12.5 0 -12.3 -12.5 01/17/2005 17:30:00 7.9 0.7 8.8 4.9 7.8 0.7 8.8 5.3 0.4 0 0.4 0.4 60 6 59 305 12 0 12 0 -12.5 0 -12.3 -12.5 01/17/2005 17:40:00 7.3 0.9 8.8 4.9 7.3 0.8 8.4 4.2 0.4 0 0.4 0.4 62 6 64 305 12 0 12 0 -12.5 0 -12.1 -12.7 01/17/2005 17:50:00 7.7 0.7 8.8 5.3 7.6 0.8 8.8 4.9 0.4 0 0.4 0.4 58 7 56 305 12 0 12 0 -12.5 0 -12.1 -12.5 01/17/2005 18:00:00 7.5 0.8 8.8 5.3 7.4 0.8 8.4 4.9 0.4 0 0.4 0.4 59 6 50 305 12 0 12 0 -12.5 0 -12.1 -12.5 01/17/2005 18:10:00 6.3 1 8.4 3 6.2 1 8.4 3.4 0.4 0 0.4 0.4 55 10 62 305 12 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 18:20:00 7.5 0.6 8.4 5.7 7.5 0.7 8.4 5.3 0.4 0 0.4 0.4 63 5 70 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 18:30:00 7.3 1 8.8 4.2 7.2 1 8.4 3.8 0.4 0 0.4 0.4 63 5 65 305 13 0 13 0 -12.4 0.1 -12.1 -12.5 01/17/2005 18:40:00 7.1 0.6 8.4 5.7 7.1 0.7 8.4 5.3 0.4 0 0.4 0.4 62 5 62 305 13 0 13 0 -12.4 0.1 -12.1 -12.5 01/17/2005 18:50:00 7.9 0.4 8.8 5.7 7.9 0.4 8.8 6.1 0.4 0 0.4 0.4 62 5 54 305 13 0 13 0 -12.5 0.1 -12.1 -12.5 01/17/2005 19:00:00 7.4 0.8 8.8 4.9 7.4 0.7 8.8 5.3 0.4 0 0.4 0.4 56 7 55 305 13 0 13 0 -12.4 0.1 -12.1 -12.5 01/17/2005 19:10:00 7.7 0.5 8.8 6.1 7.7 0.5 8.4 6.5 0.4 0 0.4 0.4 52 7 51 305 13 0 13 0 -12.4 0.1 -12.1 -12.5 01/17/2005 19:20:00 7.7 0.5 8.4 6.1 7.7 0.5 8.4 6.1 0.4 0 0.4 0.4 54 5 52 305 13 0 13 0 -12.4 0.1 -12.1 -12.5 01/17/2005 19:30:00 7.5 0.7 8.8 5.3 7.5 0.8 8.4 4.9 0.4 0 0.4 0.4 56 7 59 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 19:40:00 7.7 0.5 8.8 5.7 7.7 0.5 8.4 5.7 0.4 0 0.4 0.4 60 7 48 305 13 0 13 0 -12.5 0.1 -12.1 -12.5 01/17/2005 19:50:00 8.4 0.3 9.1 6.8 8.3 0.3 8.8 7.2 0.4 0 0.4 0.4 65 4 64 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 20:00:00 7.2 0.8 8.8 4.9 7 0.8 8.8 4.9 0.4 0 0.4 0.4 58 7 67 305 12 0 13 0 -12.4 0.1 -12.1 -12.5 01/17/2005 20:10:00 7.1 0.7 8.4 4.9 6.9 0.8 8.4 4.6 0.4 0 0.4 0.4 63 6 59 305 13 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 20:20:00 6.9 0.9 8.8 4.2 6.8 1 8.4 4.2 0.4 0 0.4 0.4 57 8 57 305 12 0 13 0 -12.4 0.1 -12.1 -12.5 01/17/2005 20:30:00 7.1 0.9 8.8 4.9 7 0.9 8.4 4.6 0.4 0 0.4 0.4 63 8 62 305 12 0 13 0 -12.5 0 -12.1 -12.5 01/17/2005 20:40:00 7.9 0.5 8.8 6.1 7.8 0.6 8.8 6.1 0.4 0 0.4 0.4 64 5 63 305 12 0 12 0 -12.4 0.1 -12.1 -12.5 01/17/2005 20:50:00 6.1 1.3 8.8 3 5.9 1.4 8.4 3 0.4 0 0.4 0.4 60 8 59 305 12 0 12 0 -12.4 0.1 -12.1 -12.5 01/17/2005 21:00:00 7.1 1 8.8 4.6 7 1 8.4 4.6 0.4 0 0.4 0.4 61 8 64 305 12 0 13 0 -12.3 0 -12.1 -12.5 01/17/2005 21:10:00 7.2 1.1 8.8 3.8 7.1 1.2 8.8 3.8 0.4 0 0.4 0.4 58 7 49 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 21:20:00 7.9 0.6 8.8 6.1 7.8 0.6 8.8 6.1 0.4 0 0.4 0.4 60 6 69 305 12 0 13 0 -12.4 0.1 -12.1 -12.5 01/17/2005 21:30:00 8.5 0.2 8.8 7.6 8.3 0.2 8.8 7.6 0.4 0 0.4 0.4 63 3 60 305 12 0 12 0 -12.4 0.1 -12.1 -12.5 01/17/2005 21:40:00 8.2 0.4 8.8 6.8 8.1 0.5 8.8 5.3 0.4 0 0.4 0.4 64 5 64 305 12 0 12 0 -12.4 0.1 -12.1 -12.5 01/17/2005 21:50:00 8 0.6 8.8 5.3 7.9 0.6 8.8 5.7 0.4 0 0.4 0.4 67 5 70 305 12 0 12 0 -12.3 0.1 -12.1 -12.5 01/17/2005 22:00:00 7.6 1 8.8 4.6 7.6 1 8.8 4.6 0.4 0 0.4 0.4 61 7 73 305 12 0 12 0 -12.2 0 -12.1 -12.5 01/17/2005 22:10:00 8.1 0.5 8.8 6.1 8.1 0.5 8.8 6.1 0.4 0 0.4 0.4 63 5 68 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 22:20:00 8.2 0.6 8.8 5.7 8.1 0.6 8.8 5.3 0.4 0 0.4 0.4 65 5 58 305 12 0 13 0 -12.3 0 -12.1 -12.5 01/17/2005 22:30:00 8.3 0.3 8.8 7.2 8.2 0.4 8.8 6.8 0.4 0 0.4 0.4 62 6 61 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 22:40:00 7.5 0.8 8.8 5.3 7.4 0.8 8.8 4.9 0.4 0 0.4 0.4 62 8 60 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 22:50:00 7.4 0.9 8.8 4.6 7.3 0.9 8.8 4.2 0.4 0 0.4 0.4 60 8 77 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 23:00:00 7.6 0.8 8.8 4.2 7.5 0.8 8.8 4.2 0.4 0 0.4 0.4 58 8 64 305 12 0 12 0 -12.2 0 -12.1 -12.5 01/17/2005 23:10:00 7.8 1 8.8 3.4 7.7 1 8.8 3.4 0.4 0 0.4 0.4 58 7 66 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 23:20:00 7.2 1.5 8.8 3.4 7 1.5 8.8 3.4 0.4 0 0.4 0.4 57 8 55 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 23:30:00 8.3 0.4 8.8 6.8 8.2 0.4 8.8 6.5 0.4 0 0.4 0.4 60 5 64 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 23:40:00 8.2 0.6 9.1 6.1 8 0.7 11.1 5.3 0.4 0 0.4 0.4 60 6 64 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/17/2005 23:50:00 7.8 0.8 9.1 4.9 7.7 0.9 8.8 4.2 0.4 0 0.4 0.4 58 8 61 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 00:00:00 7.9 0.6 8.8 5.3 7.6 0.8 8.8 4.9 0.4 0 0.4 0.4 56 8 60 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 00:10:00 8.3 0.5 9.1 6.1 8.1 0.5 8.8 5.7 0.4 0 0.4 0.4 59 6 68 305 12 0 12 0 -12.2 0 -12.1 -12.5 01/18/2005 00:20:00 8.3 0.6 9.1 5.7 8.1 0.7 8.8 5.3 0.4 0 0.4 0.4 60 6 61 305 12 0 12 0 -12.1 0 -11.9 -12.3 01/18/2005 00:30:00 8.2 0.6 8.8 5.7 8.1 0.6 8.8 5.3 0.4 0 0.4 0.4 62 5 56 305 12 0 12 0 -12.1 0 -11.9 -12.1 01/18/2005 00:40:00 8.2 0.4 8.8 6.5 8.1 0.4 8.8 6.8 0.4 0 0.4 0.4 64 3 65 305 12 0 12 0 -12.1 0 -11.9 -12.3 01/18/2005 00:50:00 8.2 0.6 9.1 6.5 8.1 0.6 8.8 6.1 0.4 0 0.4 0.4 61 6 62 305 12 0 12 0 -12.2 0 -11.9 -12.5 01/18/2005 01:00:00 9.1 1 12.2 8 9.2 1.3 12.2 7.6 0.4 0 0.4 0.4 61 4 67 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 01:10:00 9.6 1.3 12.2 8 8.8 0.8 12.6 8 0.4 0 0.4 0.4 64 3 64 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 01:20:00 9.8 1.4 12.6 8 10.1 1.5 13 8 0.4 0 0.4 0.4 64 3 64 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 01:30:00 10.4 1.6 13.3 8.4 10.1 1.7 13.3 8 0.4 0 0.4 0.4 65 3 67 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 01:40:00 9.6 1.3 13 8 8.9 1 13.7 8.4 0.4 0 0.4 0.4 65 4 63 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 01:50:00 10.6 1.6 13.3 8.4 10.5 1.7 13.3 8 0.4 0 0.4 0.4 64 4 62 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 02:00:00 11.9 0.8 13.3 8.8 11.5 1.5 13.3 8.4 0.4 0 0.4 0.4 65 3 62 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 02:10:00 10.2 1.5 13.3 8.4 9.5 1.5 13 8 0.4 0 0.4 0.4 63 4 62 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 02:20:00 9.6 1.3 12.6 8 9.2 1.3 12.6 8 0.4 0 0.4 0.4 65 4 65 305 12 0 12 0 -12.2 0 -12.1 -12.5 01/18/2005 02:30:00 8.8 0.8 11.5 7.2 8.8 1.1 11.8 6.8 0.4 0 0.4 0.4 59 5 67 305 12 0 12 0 -12.2 0 -12.1 -12.5 01/18/2005 02:40:00 8.2 0.6 9.1 6.5 8.1 0.7 11.5 6.1 0.4 0 0.4 0.4 58 5 52 305 12 0 12 0 -12.3 0 -11.9 -12.5 01/18/2005 02:50:00 11.4 1 13 8.4 10.9 1.4 13.3 8.4 0.4 0 0.4 0.4 64 3 66 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 03:00:00 9.2 1.1 13 8 8.9 1 13.3 7.2 0.4 0 0.4 0.4 64 4 61 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 03:10:00 9.4 1.7 13.3 6.8 9.3 1.7 13.3 7.2 0.4 0 0.4 0.4 63 4 62 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 03:20:00 7.9 0.6 9.1 5.7 7.8 0.6 8.8 5.7 0.4 0 0.4 0.4 59 6 65 305 12 0 12 0 -12.4 0 -12.3 -12.5 01/18/2005 03:30:00 9.1 1.5 13.3 6.8 9.1 1.6 13.3 6.1 0.4 0 0.4 0.4 60 6 62 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 03:40:00 9.6 1.4 13 7.6 9.4 1.5 13 7.2 0.4 0 0.4 0.4 62 5 64 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 03:50:00 8.6 0.4 9.1 6.8 8.7 0.9 12.2 6.8 0.4 0 0.4 0.4 60 6 66 305 12 0 12 0 -12.2 0 -12.1 -12.5 01/18/2005 04:00:00 8.3 1.1 11.8 4.9 8.2 1.2 11.8 5.7 0.4 0 0.4 0.4 62 6 61 305 12 0 12 0 -12.1 0 -11.9 -12.3 01/18/2005 04:10:00 8.5 1.1 11.8 6.1 8.6 1.3 13 6.5 0.4 0 0.4 0.4 59 6 57 305 12 0 12 0 -12.1 0 -11.9 -12.3 01/18/2005 04:20:00 7.4 0.8 8.8 4.6 7.1 1 8.8 4.6 0.4 0 0.4 0.4 54 7 51 305 12 0 12 0 -12.1 0 -11.7 -12.3 01/18/2005 04:30:00 7.9 1.3 13 4.6 7.7 1.2 13.3 4.6 0.4 0 0.4 0.4 57 9 61 305 12 0 12 0 -12.1 0 -11.9 -12.3 01/18/2005 04:40:00 8 2.5 13.3 3.4 7.7 2.6 13.7 2.3 0.4 0 0.4 0.4 57 9 58 305 11 0 11 0 -12.1 0 -11.7 -12.3 01/18/2005 04:50:00 6.4 1.2 8.8 4.2 6.3 1.2 8.8 3.8 0.4 0 0.4 0.4 47 9 58 305 11 0 12 0 -12.2 0 -12.1 -12.5 01/18/2005 05:00:00 6.7 0.9 8.8 4.6 6.6 1 8.4 4.2 0.4 0 0.4 0.4 45 8 49 305 11 0 11 0 -12.2 0 -11.9 -12.3 01/18/2005 05:10:00 7.5 0.9 8.8 4.6 7.3 0.9 8.8 4.9 0.4 0 0.4 0.4 46 7 45 305 12 0 12 0 -12.1 0 -11.9 -12.3 01/18/2005 05:20:00 8.2 0.8 11.1 6.1 8 0.8 11.8 5.3 0.4 0 0.4 0.4 47 6 47 305 12 0 12 0 -12.1 0 -11.7 -12.3 01/18/2005 05:30:00 8.3 0.7 11.8 6.1 8.1 0.5 8.8 6.5 0.4 0 0.4 0.4 48 7 54 305 12 0 12 0 -12.1 0 -11.7 -12.3 01/18/2005 05:40:00 8 0.8 11.5 5.7 7.7 0.8 10.7 4.9 0.4 0 0.4 0.4 50 8 65 305 12 0 12 0 -12.2 0.1 -11.7 -12.5 01/18/2005 05:50:00 9.5 1.7 13.7 6.1 9 1.7 14.1 5.7 0.4 0 0.4 0.4 53 7 50 305 12 0 12 0 -12.2 0 -11.9 -12.5 01/18/2005 06:00:00 7.3 1.8 12.6 3.8 7.1 1.7 12.2 3.8 0.4 0 0.4 0.4 50 9 54 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 06:10:00 7.2 1.2 8.8 3.4 6.9 1.3 8.8 3 0.4 0 0.4 0.4 46 10 50 305 11 0 11 0 -12.2 0 -12.1 -12.5 01/18/2005 06:20:00 8.8 1.8 13 4.6 8.2 1.8 13 4.6 0.4 0 0.4 0.4 54 7 55 305 12 0 12 0 -12.4 0 -12.1 -12.5 01/18/2005 06:30:00 10 1.5 13.3 7.6 9.3 1.4 13.3 6.8 0.4 0 0.4 0.4 55 6 57 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 06:40:00 9.3 1.3 13 6.1 8.5 1.1 13 5.7 0.4 0 0.4 0.4 51 8 46 305 12 0 12 0 -12.4 0 -12.1 -12.5 01/18/2005 06:50:00 9.2 1.5 13.7 5.3 8.5 1.2 13.3 4.9 0.4 0 0.4 0.4 49 8 42 305 12 0 12 0 -12.3 0 -12.1 -12.5 01/18/2005 07:00:00 9.3 1.6 13.3 6.1 8.7 1.6 13.3 5.3 0.4 0 0.4 0.4 52 8 61 305 12 0 12 0 -12.4 0.1 -12.1 -12.5 01/18/2005 07:10:00 9.9 1.8 14.5 6.1 9.3 1.7 13.3 4.9 0.4 0 0.4 0.4 53 7 51 305 12 0 12 0 -12.6 0 -12.5 -12.7 01/18/2005 07:20:00 10.9 1.7 14.5 6.8 10.1 1.7 13.7 5.3 0.4 0 0.4 0.4 54 7 56 305 12 0 12 0 -12.6 0 -12.5 -12.7 01/18/2005 07:30:00 9.3 1.7 14.5 5.7 8.9 1.6 14.9 5.7 0.4 0 0.4 0.4 48 8 53 305 12 0 12 0 -12.6 0 -12.5 -12.9 01/18/2005 07:40:00 8.9 1.1 13.3 6.8 8.6 1 12.2 6.5 0.4 0 0.4 0.4 49 7 52 305 12 0 12 0 -12.6 0 -12.5 -12.7 01/18/2005 07:50:00 8.9 1.1 13 6.5 8.5 1 12.6 6.5 0.4 0 0.4 0.4 49 7 51 305 12 0 12 0 -12.7 0 -12.5 -12.9 01/18/2005 08:00:00 8.9 1.2 12.6 6.8 8.5 1.1 12.6 6.1 0.4 0 0.4 0.4 50 7 49 305 12 0 12 0 -12.6 0 -12.3 -12.9 01/18/2005 08:10:00 8.3 0.8 12.6 6.1 8.2 1 12.6 5.7 0.4 0 0.4 0.4 49 7 59 305 12 0 12 0 -12.7 0 -12.5 -12.9 01/18/2005 08:20:00 9.2 1.1 13 7.6 9.2 1.2 13 7.2 0.4 0 0.4 0.4 53 6 56 305 12 0 12 0 -12.6 0 -12.3 -12.9 01/18/2005 08:30:00 10.3 1.7 14.1 8.4 10 1.7 13.7 8 0.4 0 0.4 0.4 58 5 67 305 12 0 12 0 -12.6 0 -12.3 -12.7 01/18/2005 08:40:00 10 1.4 13 7.6 10 1.5 13 7.6 0.4 0 0.4 0.4 51 5 52 305 12 0 12 0 -12.6 0 -12.1 -12.7 01/18/2005 08:50:00 9.4 1.3 13.7 7.6 9.2 1.4 13.7 7.2 0.4 0 0.4 0.4 49 6 51 305 12 0 12 0 -12.5 0 -12.1 -12.5 01/18/2005 09:00:00 8.3 1.2 13.7 5.3 8.1 1.2 14.1 5.7 0.4 0 0.4 0.4 51 8 51 305 12 0 12 0 -12.5 0 -12.1 -12.7 01/18/2005 09:10:00 9 1.7 13.3 6.1 8.6 1.6 14.1 5.7 0.4 0 0.4 0.4 54 8 56 305 12 0 12 0 -12.6 0 -12.3 -12.9 01/18/2005 09:20:00 11 1.9 14.9 7.6 10.6 2 14.5 7.2 0.4 0 0.4 0.4 57 6 61 305 12 0 12 0 -12.5 0 -12.1 -12.7 01/18/2005 09:30:00 13.4 1.2 15.6 10.7 13.1 1.3 15.6 8.4 0.4 0 0.4 0.4 59 4 56 305 12 0 12 0 -12.5 0 -12.1 -12.7 01/18/2005 09:40:00 14.3 0.8 16.1 12.2 14.1 1 16.4 11.1 0.4 0 0.4 0.4 59 3 61 305 11 0 12 0 -12.5 0 -12.1 -12.5 01/18/2005 09:50:00 12.7 1.3 15.3 8.4 12.2 1.7 15.6 8 0.4 0 0.4 0.4 57 5 59 305 11 0 11 0 -12.5 0 -12.1 -12.7 01/18/2005 10:00:00 13 1.3 16.1 8.8 12.7 1.4 15.6 8.4 0.4 0 0.4 0.4 58 5 63 305 11 0 11 0 -12.5 0 -12.1 -12.5 01/18/2005 10:10:00 10.9 1.6 14.5 8 10.6 1.7 14.5 7.6 0.4 0 0.4 0.4 56 6 62 305 11 0 12 0 -12.6 0 -12.1 -12.7 01/18/2005 10:20:00 9.8 1.3 13 8 9.6 1.3 13 8 0.4 0 0.4 0.4 53 6 61 305 12 0 12 0 -12.5 0 -12.1 -12.5 01/18/2005 10:30:00 11 1.6 14.1 8.4 10.7 1.7 14.1 8.4 0.4 0 0.4 0.4 52 5 51 305 12 0 12 0 -12.4 0 -12.1 -12.5 01/18/2005 10:40:00 12 1.3 14.5 8.8 12 1.4 15.3 8.4 0.4 0 0.4 0.4 50 4 50 305 13 0 13 0 -12.3 0 -12.1 -12.5 01/18/2005 10:50:00 13.2 1 15.3 10.3 13.1 1.1 15.3 10.3 0.4 0 0.4 0.4 49 4 51 305 13 0 13 0 -12.3 0 -12.1 -12.5 01/18/2005 11:00:00 12.7 1 15.3 10.3 12.7 1.2 15.6 8.4 0.4 0 0.4 0.4 48 4 47 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/18/2005 11:10:00 13.7 1 15.6 10.7 13.5 1.1 15.6 10.7 0.4 0 0.4 0.4 49 4 48 305 14 0 14 0 -12.2 0 -12.1 -12.5 01/18/2005 11:20:00 13.4 0.8 15.3 11.1 13.2 1 15.6 10.7 0.4 0 0.4 0.4 53 4 52 305 14 0 14 0 -12.2 0 -12.1 -12.5 01/18/2005 11:30:00 13.7 1.3 17.6 11.5 13.4 1.3 17.6 11.1 0.4 0 0.4 0.4 53 5 53 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/18/2005 11:40:00 14.1 1.2 16.8 11.1 13.9 1.4 17.2 10.7 0.4 0 0.4 0.4 55 5 56 305 14 0 14 0 -12.4 0.1 -12.1 -12.5 01/18/2005 11:50:00 13.6 1.3 16.8 8.8 13.4 1.5 17.2 8.8 0.4 0 0.4 0.4 54 5 56 305 14 0 14 0 -12.4 0 -12.3 -12.5 01/18/2005 12:00:00 13.3 1.4 16.8 9.1 12.9 1.7 16.4 8.4 0.4 0 0.4 0.4 56 5 58 305 14 0 14 0 -12.4 0 -12.1 -12.5 01/18/2005 12:10:00 12 1.2 15.3 8.8 11.5 1.5 15.6 8.4 0.4 0 0.4 0.4 53 6 49 305 14 0 14 0 -12.5 0 -12.3 -12.5 01/18/2005 12:20:00 13.8 1.1 16.1 9.5 13.6 1.4 16.1 9.9 0.4 0 0.4 0.4 51 5 52 305 14 0 14 0 -12.5 0 -12.5 -12.7 01/18/2005 12:30:00 13.5 1.1 16.1 11.1 13.4 1.2 16.8 9.5 0.4 0 0.4 0.4 53 4 57 305 14 0 14 0 -12.5 0 -12.3 -12.7 01/18/2005 12:40:00 13.2 1.1 16.4 10.3 13.1 1.2 16.4 10.7 0.4 0 0.4 0.4 51 5 54 305 14 0 14 0 -12.6 0 -12.5 -12.7 01/18/2005 12:50:00 12.5 1.5 15.6 8.4 12.1 1.8 16.1 8.4 0.4 0 0.4 0.4 50 5 57 305 14 0 14 0 -12.5 0 -12.3 -12.7 01/18/2005 13:00:00 12.2 1.5 15.3 8.4 11.9 1.5 14.9 8 0.4 0 0.4 0.4 49 5 47 305 14 0 14 0 -12.5 0 -12.1 -12.7 01/18/2005 13:10:00 12.6 1 15.3 9.1 12.5 1.1 14.9 8.4 0.4 0 0.4 0.4 48 5 46 305 14 0 14 0 -12.7 0 -12.5 -12.9 01/18/2005 13:20:00 13.4 1.2 16.4 10.3 13.1 1.4 16.4 9.1 0.4 0 0.4 0.4 52 5 55 305 14 0 14 0 -12.7 0 -12.5 -12.9 01/18/2005 13:30:00 13.9 1.2 16.4 11.1 13.7 1.2 17.2 10.7 0.4 0 0.4 0.4 53 4 52 305 14 0 14 0 -12.8 0 -12.5 -12.9 01/18/2005 13:40:00 14.1 1.2 17.2 11.1 13.9 1.3 17.9 10.7 0.4 0 0.4 0.4 56 4 55 305 14 0 14 0 -12.8 0 -12.5 -12.9 01/18/2005 13:50:00 13.5 1.4 16.4 9.1 13.4 1.3 16.8 10.3 0.4 0 0.4 0.4 56 4 58 305 14 0 14 0 -12.8 0 -12.5 -12.9 01/18/2005 14:00:00 13.1 1.2 16.4 9.1 12.9 1.3 16.4 8.4 0.4 0 0.4 0.4 55 5 65 305 15 0 15 0 -12.6 0 -12.3 -12.9 01/18/2005 14:10:00 13.1 1.3 16.1 9.1 12.8 1.6 16.4 8.4 0.4 0 0.4 0.4 54 5 50 305 15 0 15 0 -12.6 0 -12.3 -12.9 01/18/2005 14:20:00 14.3 1 16.4 11.5 14 1.1 16.8 11.1 0.4 0 0.4 0.4 51 5 47 305 15 0 15 0 -12.7 0 -12.5 -12.9 01/18/2005 14:30:00 14.2 1.2 17.2 11.5 13.9 1.3 17.2 11.1 0.4 0 0.4 0.4 54 4 52 305 15 0 15 0 -12.7 0 -12.5 -12.9 01/18/2005 14:40:00 15.3 1.2 17.9 11.8 15.1 1.3 17.9 10.7 0.4 0 0.4 0.4 54 4 56 305 14 0 14 0 -12.7 0 -12.5 -12.9 01/18/2005 14:50:00 15.3 1 17.2 12.6 15 1.3 17.9 11.8 0.4 0 0.4 0.4 55 3 52 305 14 0 14 0 -12.8 0 -12.5 -12.9 01/18/2005 15:00:00 15.1 1.2 17.2 12.2 14.9 1.3 17.6 10.7 0.4 0 0.4 0.4 53 4 52 305 14 0 14 0 -12.8 0 -12.5 -12.9 01/18/2005 15:10:00 13.9 1.2 16.8 10.7 13.7 1.3 16.4 8.8 0.4 0 0.4 0.4 52 5 51 305 13 0 14 0 -12.9 0.1 -12.5 -13.1 01/18/2005 15:20:00 13.4 1.3 16.1 9.1 13.2 1.5 16.1 8.4 0.4 0 0.4 0.4 51 5 51 305 13 0 13 0 -13 0 -12.7 -13.1 01/18/2005 15:30:00 14.1 0.9 16.1 11.5 13.9 1 16.4 11.1 0.4 0 0.4 0.4 51 4 49 305 13 0 13 0 -13 0 -12.7 -13.1 01/18/2005 15:40:00 12.6 1 14.5 10.3 12.5 1.2 14.5 8.4 0.4 0 0.4 0.4 50 5 51 305 13 0 13 0 -12.9 0 -12.9 -13.1 01/18/2005 15:50:00 13.1 1.1 15.6 10.7 12.9 1.2 16.1 9.9 0.4 0 0.4 0.4 49 4 48 305 13 0 13 0 -12.9 0 -12.7 -12.9 01/18/2005 16:00:00 12.7 1.3 15.6 8.8 12.5 1.5 16.1 8.4 0.4 0 0.4 0.4 52 4 52 305 13 0 13 0 -13 0 -12.7 -13.1 01/18/2005 16:10:00 13.6 1.2 16.4 10.3 13.3 1.3 15.6 9.9 0.4 0 0.4 0.4 52 4 52 305 13 0 13 0 -13.1 0 -12.9 -13.3 01/18/2005 16:20:00 13.9 1.1 16.1 10.7 13.8 1.2 16.4 11.1 0.4 0 0.4 0.4 52 4 49 305 12 0 13 0 -13.1 0 -13.1 -13.3 01/18/2005 16:30:00 14.5 1.2 16.8 10.7 14.4 1.3 16.8 11.1 0.4 0 0.4 0.4 55 3 67 305 13 0 13 0 -13.2 0 -12.9 -13.3 01/18/2005 16:40:00 14 1 16.1 11.1 13.8 1.1 16.8 11.1 0.4 0 0.4 0.4 54 4 57 305 13 0 13 0 -13.3 0 -13.1 -13.3 01/18/2005 16:50:00 15.5 1 17.2 11.5 15.4 1.1 17.6 11.1 0.4 0 0.4 0.4 54 3 52 305 13 0 13 0 -13.4 0 -13.3 -13.5 01/18/2005 17:00:00 15 0.8 16.8 12.6 15 1 17.2 12.2 0.4 0 0.4 0.4 54 3 54 305 13 0 13 0 -13.4 0 -13.3 -13.5 01/18/2005 17:10:00 14 1 15.6 11.1 13.9 1.1 16.1 11.5 0.4 0 0.4 0.4 51 4 58 305 13 0 13 0 -13.4 0 -13.3 -13.7 01/18/2005 17:20:00 13.3 1.1 15.6 10.3 13.3 1.1 16.1 10.7 0.4 0 0.4 0.4 49 4 48 305 13 0 12 0 -13.4 0 -13.3 -13.5 01/18/2005 17:30:00 12.4 1 14.9 9.1 12.2 1.3 15.3 8.4 0.4 0 0.4 0.4 47 4 48 305 13 0 13 0 -13.4 0 -13.3 -13.5 01/18/2005 17:40:00 11.5 1.7 15.3 8.8 11.6 1.7 15.3 8.4 0.4 0 0.4 0.4 46 4 48 305 13 0 13 0 -13.4 0 -13.1 -13.7 01/18/2005 17:50:00 10.7 1.4 13.7 8.4 10.7 1.5 13.7 8.4 0.4 0 0.4 0.4 45 4 48 305 13 0 13 0 -13.5 0.1 -13.1 -13.7 01/18/2005 18:00:00 11.8 1.1 14.1 8.8 11.9 1.1 14.5 8.4 0.4 0 0.4 0.4 45 4 48 305 13 0 13 0 -13.4 0 -13.1 -13.7 01/18/2005 18:10:00 12 1.2 14.5 8.8 12.2 1 14.9 9.9 0.4 0 0.4 0.4 42 5 48 305 13 0 13 0 -13.6 0 -13.3 -13.7 01/18/2005 18:20:00 12.2 1.1 14.1 8.8 12.2 1.1 14.5 8.4 0.4 0 0.4 0.4 41 5 38 305 13 0 13 0 -13.6 0 -13.3 -13.7 01/18/2005 18:30:00 12 1.2 14.1 8.8 11.9 1.3 14.9 8.4 0.4 0 0.4 0.4 41 4 38 305 13 0 13 0 -13.6 0 -13.3 -13.7 01/18/2005 18:40:00 10.7 1.7 13.3 7.6 10.6 1.8 13.7 7.6 0.4 0 0.4 0.4 43 5 37 305 13 0 13 0 -13.6 0 -13.3 -13.7 01/18/2005 18:50:00 9.9 1.6 14.1 7.2 9.7 1.7 13.7 6.8 0.4 0 0.4 0.4 47 6 45 305 13 0 13 0 -13.7 0 -13.3 -13.7 01/18/2005 19:00:00 10.7 1.7 14.1 8.4 10.7 1.8 14.9 8 0.4 0 0.4 0.4 46 5 50 305 13 0 13 0 -13.7 0 -13.3 -13.7 01/18/2005 19:10:00 9.9 1.2 13 8 10 1.4 13.3 8 0.4 0 0.4 0.4 43 5 48 305 13 0 13 0 -13.6 0 -13.3 -13.7 01/18/2005 19:20:00 11.6 1.3 14.1 8.4 11.6 1.4 13.7 8 0.4 0 0.4 0.4 44 5 41 305 13 0 13 0 -13.7 0 -13.3 -13.7 01/18/2005 19:30:00 11.1 1.7 14.5 8.4 11.1 1.7 14.1 8 0.4 0 0.4 0.4 46 5 45 305 13 0 13 0 -13.7 0 -13.3 -13.7 01/18/2005 19:40:00 11.8 1.5 14.5 8.4 11.7 1.5 14.9 8.4 0.4 0 0.4 0.4 43 5 42 305 13 0 13 0 -13.7 0 -13.3 -13.7 01/18/2005 19:50:00 11.6 1.3 14.1 8.8 11.6 1.4 14.1 8.4 0.4 0 0.4 0.4 46 5 48 305 13 0 13 0 -13.7 0 -13.3 -13.7 01/18/2005 20:00:00 12 1.5 14.9 8.4 12 1.5 14.9 8.4 0.4 0 0.4 0.4 47 5 51 305 13 0 13 0 -13.7 0 -13.5 -13.7 01/18/2005 20:10:00 11.1 1.4 13.7 8 11 1.5 13.3 7.6 0.4 0 0.4 0.4 40 6 47 305 13 0 13 0 -13.7 0 -13.5 -13.7 01/18/2005 20:20:00 12.4 1.5 16.1 8.8 12.4 1.6 16.1 8.4 0.4 0 0.4 0.4 47 5 44 305 13 0 13 0 -13.7 0 -13.3 -13.9 01/18/2005 20:30:00 11.4 1.9 15.6 8.4 11.1 1.9 15.6 8.4 0.4 0 0.4 0.4 49 6 37 305 13 0 12 0 -13.8 0 -13.5 -13.9 01/18/2005 20:40:00 13.6 1.5 16.4 8.8 13.6 1.6 16.8 8.4 0.4 0 0.4 0.4 48 5 46 305 13 0 12 0 -13.7 0 -13.5 -13.9 01/18/2005 20:50:00 14 1.2 16.4 10.7 13.8 1.2 16.4 11.1 0.4 0 0.4 0.4 47 5 46 305 13 0 13 0 -13.8 0 -13.5 -13.9 01/18/2005 21:00:00 13.8 1.4 17.2 10.7 13.7 1.5 16.8 10.7 0.4 0 0.4 0.4 46 5 51 305 13 0 13 0 -13.9 0 -13.7 -14.1 01/18/2005 21:10:00 14 1.1 16.4 11.1 13.8 1.2 16.8 9.9 0.4 0 0.4 0.4 49 5 44 305 12 0 12 0 -14 0 -13.7 -14.3 01/18/2005 21:20:00 13.1 1.4 16.1 8.8 13.1 1.5 16.4 8.8 0.4 0 0.4 0.4 45 6 48 305 12 0 12 0 -14.1 0 -13.9 -14.3 01/18/2005 21:30:00 14.5 1.1 17.2 11.1 14.5 1.1 17.2 11.5 0.4 0 0.4 0.4 47 4 50 305 12 0 12 0 -14.1 0 -13.7 -14.3 01/18/2005 21:40:00 14 1.5 16.8 10.3 13.8 1.6 17.2 10.3 0.4 0 0.4 0.4 45 5 45 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/18/2005 21:50:00 14.7 1.1 16.8 11.5 14.7 1.2 17.2 11.1 0.4 0 0.4 0.4 43 4 42 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/18/2005 22:00:00 14.8 1 16.8 11.1 14.8 1.2 16.8 11.1 0.4 0 0.4 0.4 45 4 46 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/18/2005 22:10:00 14.8 1.3 17.6 11.5 14.8 1.4 17.6 11.1 0.4 0 0.4 0.4 44 4 45 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/18/2005 22:20:00 15.8 1.4 18.7 12.2 15.8 1.5 18.7 11.5 0.4 0 0.4 0.4 45 4 44 305 12 0 12 0 -14.2 0 -13.7 -14.3 01/18/2005 22:30:00 15 1.5 17.9 11.5 15 1.5 18.7 11.8 0.4 0 0.4 0.4 44 5 46 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/18/2005 22:40:00 14.3 1.5 17.2 11.5 14.3 1.5 17.2 11.1 0.4 0 0.4 0.4 45 5 49 305 12 0 12 0 -14.2 0 -13.9 -14.3 01/18/2005 22:50:00 15.4 1.2 17.9 11.8 15.5 1.3 17.9 11.8 0.4 0 0.4 0.4 41 4 48 305 12 0 12 0 -14.2 0 -13.9 -14.4 01/18/2005 23:00:00 14 1.3 16.8 10.7 14 1.3 17.2 10.7 0.4 0 0.4 0.4 41 5 38 305 12 0 12 0 -14.2 0 -13.9 -14.4 01/18/2005 23:10:00 15.2 1.3 17.9 11.5 15.3 1.4 18.3 11.1 0.4 0 0.4 0.4 39 5 42 305 12 0 12 0 -14.3 0 -14.1 -14.4 01/18/2005 23:20:00 14.7 1.2 17.6 11.5 14.5 1.3 17.9 11.1 0.4 0 0.4 0.4 42 5 40 305 11 0 11 0 -14.4 0 -14.3 -14.6 01/18/2005 23:30:00 13.4 1.2 17.2 11.1 13.4 1.2 17.2 9.9 0.4 0 0.4 0.4 38 5 36 305 11 0 11 0 -14.4 0 -14.3 -14.6 01/18/2005 23:40:00 14.7 1 17.2 11.1 14.8 1.1 17.2 11.5 0.4 0 0.4 0.4 38 5 36 305 11 0 11 0 -14.5 0 -14.3 -14.6 01/18/2005 23:50:00 14.6 1.7 17.6 10.3 14.6 1.9 17.9 8.4 0.4 0 0.4 0.4 38 4 40 305 11 0 11 0 -14.6 0.1 -14.3 -14.6 01/19/2005 00:00:00 14.5 1.2 16.8 10.7 14.5 1.2 17.2 11.1 0.4 0 0.4 0.4 37 4 40 305 11 0 11 0 -14.6 0 -14.3 -14.6 01/19/2005 00:10:00 15 0.9 16.8 12.6 14.9 1 17.2 12.2 0.4 0 0.4 0.4 38 4 39 305 11 0 11 0 -14.7 0 -14.4 -14.6 01/19/2005 00:20:00 15.1 1.2 17.9 12.2 15 1.3 18.3 11.8 0.4 0 0.4 0.4 41 4 39 305 11 0 11 0 -14.7 0 -14.4 -14.6 01/19/2005 00:30:00 16.5 1.1 18.3 13.3 16.4 1.1 19.1 13.7 0.4 0 0.4 0.4 44 4 43 305 11 0 11 0 -14.7 0 -14.4 -14.8 01/19/2005 00:40:00 17.3 0.9 19.1 14.5 17.3 1.1 19.5 14.1 0.4 0 0.4 0.4 41 3 37 305 11 0 11 0 -14.8 0 -14.6 -15 01/19/2005 00:50:00 17.3 1 19.5 13.7 17.2 1.2 19.9 13 0.4 0 0.4 0.4 41 4 41 305 11 0 11 0 -14.8 0 -14.6 -15 01/19/2005 01:00:00 16.3 1.5 19.1 12.2 16.1 1.7 19.5 11.8 0.4 0 0.4 0.4 43 5 40 305 11 0 11 0 -14.8 0 -14.6 -15 01/19/2005 01:10:00 16.1 1.5 19.1 11.5 15.7 1.7 19.1 11.5 0.4 0 0.4 0.4 47 6 48 305 11 0 11 0 -14.8 0 -14.6 -15 01/19/2005 01:20:00 16.3 1.3 18.7 12.2 16.1 1.4 18.7 12.2 0.4 0 0.4 0.4 49 5 48 305 11 0 11 0 -14.8 0 -14.6 -15 01/19/2005 01:30:00 17.7 1.4 20.2 13.7 17.4 1.5 20.6 13.3 0.4 0 0.4 0.4 49 3 46 305 11 0 11 0 -14.9 0 -14.6 -15 01/19/2005 01:40:00 16 1.7 20.2 11.1 15.9 1.8 20.2 11.5 0.4 0 0.4 0.4 48 6 43 305 11 0 11 0 -14.8 0 -14.6 -15 01/19/2005 01:50:00 15.8 1.5 19.1 11.5 15.7 1.5 19.1 11.1 0.4 0 0.4 0.4 48 5 31 305 11 0 11 0 -14.9 0 -14.6 -15 01/19/2005 02:00:00 16 1.3 18.7 12.6 15.9 1.3 18.7 12.6 0.4 0 0.4 0.4 47 5 50 305 11 0 11 0 -14.9 0 -14.6 -15 01/19/2005 02:10:00 16.5 1.6 20.2 12.6 16.4 1.7 20.2 12.2 0.4 0 0.4 0.4 47 5 51 305 11 0 11 0 -15 0 -14.6 -15 01/19/2005 02:20:00 14.8 1.3 18.7 12.2 14.7 1.3 18.3 11.8 0.4 0 0.4 0.4 48 6 49 305 11 0 11 0 -15 0 -14.6 -15.2 01/19/2005 02:30:00 16.2 1.2 18.7 13.3 16 1.3 19.1 12.2 0.4 0 0.4 0.4 48 4 50 305 11 0 11 0 -15 0 -14.6 -15 01/19/2005 02:40:00 15.3 1.4 18.3 11.1 15.3 1.5 18.3 11.5 0.4 0 0.4 0.4 48 5 46 305 11 0 11 0 -15.1 0 -14.8 -15.2 01/19/2005 02:50:00 15 1.2 17.9 11.8 14.8 1.2 17.6 11.5 0.4 0 0.4 0.4 46 5 45 305 11 0 11 0 -15.1 0.1 -14.8 -15.2 01/19/2005 03:00:00 16.1 1.2 18.7 12.6 16 1.3 18.7 12.2 0.4 0 0.4 0.4 47 5 45 305 11 0 11 0 -15.2 0 -14.8 -15.2 01/19/2005 03:10:00 16 1.3 18.7 11.8 15.7 1.5 19.5 11.1 0.4 0 0.4 0.4 49 4 49 305 11 0 11 0 -15.2 0 -15 -15.4 01/19/2005 03:20:00 14.4 1.8 17.9 8.8 14.2 1.7 17.9 9.1 0.4 0 0.4 0.4 46 5 50 305 11 0 11 0 -15.2 0 -15 -15.2 01/19/2005 03:30:00 14.9 1.1 17.2 10.3 14.7 1.1 17.6 11.1 0.4 0 0.4 0.4 43 5 47 305 11 0 11 0 -15.2 0 -15 -15.2 01/19/2005 03:40:00 12.5 1.2 14.9 8.8 12.4 1.2 15.3 8.4 0.4 0 0.4 0.4 44 5 40 305 11 0 11 0 -15.2 0 -15 -15.2 01/19/2005 03:50:00 14.4 1.2 16.8 10.3 14.1 1.3 16.8 9.9 0.4 0 0.4 0.4 45 5 45 305 11 0 11 0 -15.2 0 -15 -15.2 01/19/2005 04:00:00 15 1.5 17.2 11.1 14.7 1.5 17.2 10.7 0.4 0 0.4 0.4 49 5 49 305 11 0 11 0 -15.2 0 -15 -15.2 01/19/2005 04:10:00 12.8 1.9 16.1 8.4 12.7 1.9 16.1 8 0.4 0 0.4 0.4 46 5 46 305 11 0 11 0 -15.2 0 -15 -15.2 01/19/2005 04:20:00 13.4 2 16.4 8.8 13.1 2 16.4 8.4 0.4 0 0.4 0.4 46 5 49 305 11 0 11 0 -15.2 0 -15 -15.4 01/19/2005 04:30:00 13.9 1.3 16.8 10.7 13.6 1.4 16.8 9.9 0.4 0 0.4 0.4 46 5 43 305 11 0 10 0 -15.2 0 -15 -15.2 01/19/2005 04:40:00 13.1 1.8 16.4 8.8 13 1.8 17.2 8.4 0.4 0 0.4 0.4 47 5 47 305 10 0 11 0 -15.2 0 -14.8 -15.2 01/19/2005 04:50:00 14.6 1.3 16.8 11.5 14.5 1.5 17.6 10.3 0.4 0 0.4 0.4 46 4 53 305 10 0 11 0 -15.2 0 -15 -15.2 01/19/2005 05:00:00 13.4 1.4 16.4 9.1 13.2 1.5 16.4 8.4 0.4 0 0.4 0.4 45 6 49 305 10 0 10 0 -15.2 0 -15 -15.2 01/19/2005 05:10:00 14.9 1.3 17.9 11.1 14.7 1.5 17.9 10.3 0.4 0 0.4 0.4 47 4 46 305 10 0 10 0 -15.2 0 -15 -15.2 01/19/2005 05:20:00 13.9 1.5 17.2 8.8 13.8 1.6 17.2 10.3 0.4 0 0.4 0.4 47 5 45 305 10 0 10 0 -15.2 0 -15 -15.4 01/19/2005 05:30:00 12.7 1.4 16.1 8.4 12.5 1.5 16.1 8.4 0.4 0 0.4 0.4 45 6 44 305 10 0 10 0 -15.2 0 -15 -15.6 01/19/2005 05:40:00 12.8 1.9 16.4 8.4 12.8 1.7 16.8 8.4 0.4 0 0.4 0.4 46 5 42 305 10 0 10 0 -15.3 0 -15 -15.4 01/19/2005 05:50:00 13.4 1.5 16.8 8.8 13.1 1.5 16.8 8 0.4 0 0.4 0.4 48 5 48 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 06:00:00 11.9 2 16.1 7.6 11.7 2.2 16.4 8 0.4 0 0.4 0.4 46 6 49 305 10 0 10 0 -15.4 0 -15.2 -15.6 01/19/2005 06:10:00 12.4 1.3 15.3 8.8 12.1 1.4 15.3 8.4 0.4 0 0.4 0.4 49 6 41 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 06:20:00 13.3 1.7 16.4 8.8 13.2 1.7 16.1 8.4 0.4 0 0.4 0.4 45 5 40 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 06:30:00 13.6 1.4 16.4 8.8 13.6 1.3 16.4 8.8 0.4 0 0.4 0.4 44 5 45 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 06:40:00 12.3 2.2 16.4 8 12.1 2.3 15.6 8 0.4 0 0.4 0.4 42 6 33 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 06:50:00 11.4 1.7 15.6 8.4 11.1 1.7 14.9 8.4 0.4 0 0.4 0.4 42 6 43 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 07:00:00 10.8 1.7 15.3 8 10.9 1.7 15.3 8 0.4 0 0.4 0.4 39 6 47 305 10 0 10 0 -15.3 0 -15 -15.6 01/19/2005 07:10:00 11.4 1.7 14.9 8 11.2 1.9 15.3 7.6 0.4 0 0.4 0.4 44 6 46 305 10 0 10 0 -15.5 0 -15.2 -15.6 01/19/2005 07:20:00 10.6 1.9 16.1 6.8 10.3 1.9 15.6 7.2 0.4 0 0.4 0.4 43 7 48 305 10 0 10 0 -15.6 0 -15.2 -15.6 01/19/2005 07:30:00 12.6 1.7 16.1 6.8 12.3 1.7 15.6 6.8 0.4 0 0.4 0.4 43 6 46 305 10 0 10 0 -15.6 0 -15.2 -15.8 01/19/2005 07:40:00 13.2 1.8 16.4 8.4 13.1 1.9 16.8 8.4 0.4 0 0.4 0.4 43 5 51 305 10 0 10 0 -15.6 0 -15.4 -15.8 01/19/2005 07:50:00 13.4 1.3 16.4 9.1 13.3 1.5 16.4 8.8 0.4 0 0.4 0.4 43 6 40 305 10 0 9 0 -15.7 0 -15.6 -15.8 01/19/2005 08:00:00 13.3 1.3 16.1 8.8 13.2 1.4 16.4 9.5 0.4 0 0.4 0.4 45 5 49 305 10 0 9 0 -15.7 0 -15.6 -15.8 01/19/2005 08:10:00 14.3 1.3 17.6 10.7 14.2 1.3 17.2 10.7 0.4 0 0.4 0.4 47 5 44 305 9 0 9 0 -15.7 0 -15.4 -15.8 01/19/2005 08:20:00 13.8 1.2 17.2 10.3 13.7 1.4 17.2 10.3 0.4 0 0.4 0.4 48 5 48 305 9 0 9 0 -15.7 0 -15.4 -15.8 01/19/2005 08:30:00 13.7 1.7 16.8 8.4 13.5 1.9 16.4 8.4 0.4 0 0.4 0.4 43 5 40 305 10 0 9 0 -15.6 0 -15.4 -15.8 01/19/2005 08:40:00 13.1 1.3 16.1 8.8 12.9 1.5 16.4 8.4 0.4 0 0.4 0.4 45 5 43 305 10 0 9 0 -15.6 0 -15.4 -15.8 01/19/2005 08:50:00 11.9 1.1 14.9 8.8 11.7 1.2 14.5 8.4 0.4 0 0.4 0.4 45 5 45 305 10 0 9 0 -15.7 0 -15.2 -15.8 01/19/2005 09:00:00 10.3 1.5 13.7 8.4 10.1 1.7 14.1 8.4 0.4 0 0.4 0.4 38 6 47 305 10 0 9 0 -15.6 0 -15.2 -15.6 01/19/2005 09:10:00 11.9 1.1 14.5 8.8 11.9 1.2 14.9 8.4 0.4 0 0.4 0.4 41 6 45 305 10 0 9 0 -15.6 0 -15.4 -15.8 01/19/2005 09:20:00 11.5 1.4 14.5 8.4 11.5 1.4 14.9 8.4 0.4 0 0.4 0.4 39 5 27 305 10 0 10 0 -15.6 0 -15.2 -15.8 01/19/2005 09:30:00 13.3 1.3 16.4 8.8 13.3 1.3 16.4 9.1 0.4 0 0.4 0.4 41 6 49 305 10 0 10 0 -15.6 0 -15.4 -15.8 01/19/2005 09:40:00 13.8 1.1 16.1 11.1 13.8 1.2 16.4 9.9 0.4 0 0.4 0.4 35 4 32 305 10 0 9 0 -15.7 0.1 -15.4 -15.8 01/19/2005 09:50:00 14.7 1.1 17.2 11.1 14.8 1.3 17.2 11.1 0.4 0 0.4 0.4 36 3 36 305 9 0 9 0 -15.8 0 -15.6 -15.8 01/19/2005 10:00:00 14.7 1 17.2 11.5 14.8 1 17.2 11.8 0.4 0 0.4 0.4 37 4 37 305 9 0 9 0 -15.7 0 -15.4 -15.8 01/19/2005 10:10:00 14.4 1.1 16.4 11.5 14.3 1.2 17.2 11.5 0.4 0 0.4 0.4 37 4 42 305 10 0 9 0 -15.7 0 -15.4 -15.8 01/19/2005 10:20:00 14.2 1.4 17.2 11.1 14.2 1.5 17.6 10.7 0.4 0 0.4 0.4 36 3 34 305 10 0 9 0 -15.6 0.1 -15.4 -15.8 01/19/2005 10:30:00 13.9 1.1 16.4 8.8 13.9 1.1 16.4 10.7 0.4 0 0.4 0.4 37 6 36 305 10 0 9 0 -15.7 0 -15.4 -15.8 01/19/2005 10:40:00 14.6 1 16.8 12.2 14.6 1.1 16.8 11.8 0.4 0 0.4 0.4 40 4 43 305 10 0 9 0 -15.7 0 -15.2 -15.8 01/19/2005 10:50:00 13.5 1 16.4 10.7 13.6 1.2 17.2 8.8 0.4 0 0.4 0.4 41 5 45 305 10 0 9 0 -15.6 0 -15.4 -15.8 01/19/2005 11:00:00 15 1.5 18.3 11.5 14.9 1.5 18.3 11.5 0.4 0 0.4 0.4 39 5 38 305 10 0 9 0 -15.6 0 -15.2 -15.8 01/19/2005 11:10:00 15 1.2 17.6 11.8 15 1.4 17.9 11.5 0.4 0 0.4 0.4 43 4 48 305 10 0 9 0 -15.6 0 -15.2 -15.8 01/19/2005 11:20:00 15.5 1.2 18.3 12.2 15.4 1.3 18.3 12.2 0.4 0 0.4 0.4 44 4 47 305 10 0 10 0 -15.5 0 -15 -15.6 01/19/2005 11:30:00 14.9 1 17.2 11.1 14.8 1.2 17.6 11.8 0.4 0 0.4 0.4 46 4 39 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 11:40:00 12.8 1.5 16.1 8.8 12.6 1.6 16.8 8.4 0.4 0 0.4 0.4 41 5 48 305 10 0 10 0 -15.3 0 -15 -15.6 01/19/2005 11:50:00 12.3 1.5 15.6 8.8 12.1 1.6 15.6 8.4 0.4 0 0.4 0.4 38 5 34 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 12:00:00 13.2 1.3 16.8 8.8 12.9 1.4 16.8 8.4 0.4 0 0.4 0.4 41 5 40 305 10 0 10 0 -15.3 0 -15 -15.6 01/19/2005 12:10:00 13.3 1.2 16.1 9.9 13 1.5 16.1 8.4 0.4 0 0.4 0.4 37 5 34 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 12:20:00 15.2 1.2 17.6 11.8 14.9 1.4 18.3 11.5 0.4 0 0.4 0.4 41 5 40 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 12:30:00 15.8 1.4 18.7 12.2 15.8 1.5 19.1 12.6 0.4 0 0.4 0.4 44 4 42 305 10 0 10 0 -15.3 0 -15 -15.6 01/19/2005 12:40:00 14.7 1.5 17.9 11.1 14.6 1.4 17.6 10.7 0.4 0 0.4 0.4 40 5 28 305 10 0 10 0 -15.3 0 -15 -15.4 01/19/2005 12:50:00 14.5 1.2 17.9 11.8 14.4 1.4 18.3 11.5 0.4 0 0.4 0.4 40 5 42 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 13:00:00 15.4 1.2 17.9 12.2 15.3 1.3 17.9 11.1 0.4 0 0.4 0.4 40 5 36 305 10 0 10 0 -15.3 0 -15 -15.6 01/19/2005 13:10:00 13.6 1.5 16.8 9.1 13.5 1.7 16.4 8.8 0.4 0 0.4 0.4 39 5 28 305 10 0 10 0 -15.3 0 -15 -15.6 01/19/2005 13:20:00 12.7 1 14.9 9.5 12.6 1.1 15.3 9.5 0.4 0 0.4 0.4 31 5 27 305 10 0 9 0 -15.6 0 -15.2 -15.8 01/19/2005 13:30:00 13.9 1 16.1 11.1 13.8 1.1 16.1 10.7 0.4 0 0.4 0.4 33 3 35 305 9 0 9 0 -15.6 0 -15.2 -15.8 01/19/2005 13:40:00 14 0.9 15.6 11.5 13.9 1 16.4 10.3 0.4 0 0.4 0.4 35 4 32 305 10 0 10 0 -15.5 0 -15.2 -15.6 01/19/2005 13:50:00 12.7 1.5 15.6 8.8 12.6 1.5 15.6 8.4 0.4 0 0.4 0.4 34 5 31 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 14:00:00 13.2 1.5 15.6 8.4 13.2 1.5 15.6 8.4 0.4 0 0.4 0.4 35 4 38 305 10 0 10 0 -15.3 0 -15 -15.6 01/19/2005 14:10:00 13.1 1.1 16.1 8.8 13.1 1.2 15.6 8.8 0.4 0 0.4 0.4 37 5 36 305 10 0 10 0 -15.3 0 -15 -15.4 01/19/2005 14:20:00 13.6 1.4 16.4 8.8 13.3 1.3 16.8 8.8 0.4 0 0.4 0.4 33 4 33 305 10 0 10 0 -15.3 0 -15 -15.4 01/19/2005 14:30:00 13.5 1.3 16.4 9.5 13.5 1.3 16.8 10.3 0.4 0 0.4 0.4 35 5 30 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 14:40:00 11.4 1.3 14.1 8.4 11.4 1.4 14.5 8.4 0.4 0 0.4 0.4 27 5 38 305 10 0 10 0 -15.4 0 -15 -15.6 01/19/2005 14:50:00 11.1 1.2 13.7 8.4 11.2 1.3 13.7 8.4 0.4 0 0.4 0.4 28 5 27 305 10 0 10 0 -15.3 0 -15 -15.6 01/19/2005 15:00:00 10.2 1.5 13.3 7.6 10 1.5 13.7 7.6 0.4 0 0.4 0.4 28 6 29 305 10 0 9 0 -15.3 0 -15 -15.6 01/19/2005 15:10:00 12.1 1.3 14.5 8.8 12.1 1.3 14.9 8.4 0.4 0 0.4 0.4 27 5 29 305 9 0 9 0 -15.4 0 -15 -15.6 01/19/2005 15:20:00 11.7 1.3 14.1 8.4 11.6 1.3 14.1 8.4 0.4 0 0.4 0.4 27 5 37 305 9 0 9 0 -15.4 0 -15 -15.6 01/19/2005 15:30:00 10.8 1.5 13.7 8 10.8 1.7 13.7 8 0.4 0 0.4 0.4 32 5 33 305 9 0 9 0 -15.3 0 -15 -15.4 01/19/2005 15:40:00 11.2 1.6 13.7 8.4 11.2 1.6 13.7 8.4 0.4 0 0.4 0.4 24 5 27 305 9 0 9 0 -15.4 0 -15 -15.6 01/19/2005 15:50:00 10.8 1.4 13.7 8.4 10.7 1.5 13.7 8.4 0.4 0 0.4 0.4 28 6 23 305 9 0 9 0 -15.5 0 -15 -15.6 01/19/2005 16:00:00 12.6 1.1 14.9 8.8 12.6 1.2 15.3 8.8 0.4 0 0.4 0.4 34 5 36 305 9 0 9 0 -15.4 0 -15 -15.6 01/19/2005 16:10:00 12.8 1 15.6 10.3 12.6 1.1 15.3 10.3 0.4 0 0.4 0.4 37 5 37 305 8 0 8 0 -15.5 0 -15 -15.6 01/19/2005 16:20:00 11.9 1.5 14.9 8 11.8 1.6 15.3 7.6 0.4 0 0.4 0.4 37 5 42 305 8 0 8 0 -15.5 0 -15.2 -15.6 01/19/2005 16:30:00 12.2 1.3 14.5 8.8 12.1 1.4 14.5 8.4 0.4 0 0.4 0.4 36 4 40 305 8 0 8 0 -15.5 0 -15 -15.6 01/19/2005 16:40:00 12 1.2 14.1 8.8 12.2 1.2 14.5 8.4 0.4 0 0.4 0.4 37 4 31 305 9 1 8 0 -15.6 0.1 -15.2 -15.8 01/19/2005 16:50:00 11.8 1.6 14.5 8.4 11.6 1.7 14.5 8.4 0.4 0 0.4 0.4 36 5 36 305 8 0 8 0 -15.7 0 -15.2 -15.8 01/19/2005 17:00:00 11.3 1.6 15.3 8 11.3 1.6 14.9 8 0.4 0 0.4 0.4 36 5 39 305 7 0 8 0 -15.8 0 -15.4 -16 01/19/2005 17:10:00 11.5 1.5 15.3 8 11.5 1.6 14.9 8 0.4 0 0.4 0.4 37 5 38 305 7 0 7 0 -15.8 0 -15.6 -16 01/19/2005 17:20:00 10.6 1.2 13.3 8.4 10.6 1.3 13.3 8 0.4 0 0.4 0.4 37 5 48 305 7 0 7 0 -15.8 0 -15.6 -16 01/19/2005 17:30:00 10.2 1.2 12.6 7.6 10.2 1.3 13.3 7.6 0.4 0 0.4 0.4 33 5 45 305 7 0 7 0 -15.8 0 -15.6 -16 01/19/2005 17:40:00 9.4 1.2 13 6.8 9.4 1.3 13 6.8 0.4 0 0.4 0.4 36 6 41 305 8 0 8 0 -15.8 0 -15.6 -16 01/19/2005 17:50:00 10.4 1.2 13 8.4 10.3 1.3 13.3 7.6 0.4 0 0.4 0.4 39 4 39 305 8 0 8 0 -15.9 0 -15.8 -16 01/19/2005 18:00:00 9.5 1.2 13 7.2 9.4 1.3 13.3 7.2 0.4 0 0.4 0.4 36 5 31 305 8 0 8 0 -15.9 0 -15.8 -16 01/19/2005 18:10:00 9.6 1.1 12.6 7.6 9.5 1.1 12.6 6.8 0.4 0 0.4 0.4 32 5 25 305 8 0 8 0 -15.9 0 -15.8 -16 01/19/2005 18:20:00 10 1.2 12.6 8 10.1 1.3 12.6 8 0.4 0 0.4 0.4 34 5 38 305 8 0 8 0 -16 0 -15.6 -16 01/19/2005 18:30:00 9.4 1.2 12.6 7.6 9.3 1.2 13 6.8 0.4 0 0.4 0.4 32 5 36 305 8 0 8 0 -16 0 -15.8 -16 01/19/2005 18:40:00 10.1 1.3 13.3 8 9.8 1.4 13 7.6 0.4 0 0.4 0.4 34 5 30 305 8 0 8 0 -16 0 -15.8 -16 01/19/2005 18:50:00 10.2 1.2 13 8 9.9 1.3 13 7.6 0.4 0 0.4 0.4 35 5 35 305 8 0 8 0 -15.9 0 -15.6 -16 01/19/2005 19:00:00 10.6 1.5 14.1 8 10.4 1.5 13.7 8 0.4 0 0.4 0.4 32 5 26 305 8 0 8 0 -15.9 0 -15.8 -16 01/19/2005 19:10:00 11.9 1.3 14.5 8.8 11.8 1.5 14.5 8.4 0.4 0 0.4 0.4 33 5 32 305 8 0 8 0 -15.9 0 -15.6 -16 01/19/2005 19:20:00 11.7 1.3 14.5 8 11.5 1.4 14.1 8 0.4 0 0.4 0.4 33 6 35 305 8 0 8 0 -16 0 -15.8 -16.2 01/19/2005 19:30:00 11.1 1.2 14.1 8.4 10.9 1.2 14.1 8.4 0.4 0 0.4 0.4 33 5 30 305 8 0 8 0 -16.1 0 -15.8 -16.2 01/19/2005 19:40:00 11 1.7 14.9 7.6 10.9 1.7 14.9 7.6 0.4 0 0.4 0.4 34 5 36 305 8 0 8 0 -16.1 0 -15.8 -16.2 01/19/2005 19:50:00 10.7 1.6 13.7 8 10.7 1.6 13.7 7.2 0.4 0 0.4 0.4 33 5 30 305 8 0 8 0 -16.1 0 -15.8 -16.2 01/19/2005 20:00:00 12 1.5 15.3 8.8 12 1.3 15.3 8.4 0.4 0 0.4 0.4 34 4 32 305 8 0 8 0 -16.1 0 -15.8 -16.2 01/19/2005 20:10:00 11.7 1.3 14.5 8.8 11.7 1.2 14.1 8.8 0.4 0 0.4 0.4 34 5 37 305 8 0 8 0 -16.1 0 -15.8 -16.2 01/19/2005 20:20:00 12 1.5 14.9 8 11.8 1.7 14.9 7.6 0.4 0 0.4 0.4 33 5 32 305 8 0 8 0 -16 0.1 -15.8 -16.2 01/19/2005 20:30:00 11.4 1.5 14.9 8.4 11.3 1.4 14.1 8 0.4 0 0.4 0.4 33 5 28 305 8 0 8 0 -16.1 0 -15.8 -16.2 01/19/2005 20:40:00 10.4 1.6 14.1 7.6 10.3 1.5 13.3 7.6 0.4 0 0.4 0.4 32 7 24 305 8 0 8 0 -16.2 0 -16 -16.4 01/19/2005 20:50:00 11.9 1 13.7 8.8 11.6 1.2 14.1 8.4 0.4 0 0.4 0.4 31 5 30 305 8 0 8 0 -16.1 0 -15.8 -16.4 01/19/2005 21:00:00 10.9 1.3 13.7 8 10.6 1.3 13.3 8 0.4 0 0.4 0.4 30 6 22 305 8 0 8 0 -16.2 0.1 -15.8 -16.4 01/19/2005 21:10:00 12.2 1.3 14.9 8.8 12.1 1.3 14.5 8.4 0.4 0 0.4 0.4 30 4 31 305 8 0 8 0 -16.1 0 -15.8 -16.4 01/19/2005 21:20:00 10.4 1.3 13 7.6 10.3 1.4 13 7.2 0.4 0 0.4 0.4 32 5 31 305 8 0 8 0 -16.2 0.1 -16 -16.4 01/19/2005 21:30:00 10.1 1.1 12.2 8.4 10 1.1 12.6 8.4 0.4 0 0.4 0.4 34 5 35 305 8 0 8 0 -16.3 0 -16 -16.4 01/19/2005 21:40:00 11.5 1.5 14.1 8.4 11.3 1.4 14.5 8.4 0.4 0 0.4 0.4 30 5 33 305 8 0 8 0 -16.3 0 -16 -16.4 01/19/2005 21:50:00 12.1 1 14.5 8.8 11.9 1.1 13.7 8.4 0.4 0 0.4 0.4 29 5 30 305 8 0 8 0 -16.3 0 -16 -16.4 01/19/2005 22:00:00 11.2 1.3 13.3 8.4 11 1.3 13.7 8 0.4 0 0.4 0.4 31 5 31 305 8 0 8 0 -16.2 0 -16 -16.4 01/19/2005 22:10:00 10.8 1.3 13.3 8.4 10.8 1.2 13.3 8.4 0.4 0 0.4 0.4 26 5 27 305 8 0 8 0 -16.2 0.1 -16 -16.4 01/19/2005 22:20:00 12.3 1.1 14.9 8.4 12.2 1.2 14.9 8.4 0.4 0 0.4 0.4 29 4 35 305 8 0 8 0 -16.2 0 -16 -16.4 01/19/2005 22:30:00 12.2 1.5 15.6 8.4 12 1.6 15.3 8.4 0.4 0 0.4 0.4 29 4 27 305 8 0 8 0 -16.3 0 -16 -16.4 01/19/2005 22:40:00 11.7 1.5 14.9 8.8 11.5 1.5 14.9 8.4 0.4 0 0.4 0.4 28 5 24 305 8 0 8 0 -16.3 0 -16 -16.4 01/19/2005 22:50:00 11.6 1.3 14.1 8.4 11.4 1.3 14.1 8.4 0.4 0 0.4 0.4 28 6 26 305 8 0 7 0 -16.3 0 -16 -16.4 01/19/2005 23:00:00 11.4 1.7 14.5 7.2 11.2 1.7 14.5 7.6 0.4 0 0.4 0.4 27 5 23 305 8 0 8 0 -16.2 0 -16 -16.4 01/19/2005 23:10:00 11.9 1.6 14.9 8.4 11.7 1.7 14.5 8.4 0.4 0 0.4 0.4 28 5 24 305 8 0 8 0 -16.2 0 -16 -16.4 01/19/2005 23:20:00 11.8 1.5 14.9 7.6 11.6 1.5 14.5 8 0.4 0 0.4 0.4 28 6 24 305 8 0 7 0 -16.3 0 -16 -16.4 01/19/2005 23:30:00 12 1.4 14.9 8.4 11.8 1.5 14.9 8 0.4 0 0.4 0.4 29 5 33 305 8 0 8 0 -16.2 0 -16 -16.4 01/19/2005 23:40:00 11.6 1.6 14.5 8.4 11.5 1.5 14.5 8 0.4 0 0.4 0.4 29 5 22 305 8 0 8 0 -16.2 0 -16 -16.4 01/19/2005 23:50:00 11.7 1.7 15.3 8 11.6 1.7 15.3 7.6 0.4 0 0.4 0.4 26 5 21 305 8 0 7 0 -16.3 0 -16 -16.4 01/20/2005 00:00:00 12 1.6 14.9 8.4 11.8 1.5 14.9 8.4 0.4 0 0.4 0.4 27 5 29 305 7 0 7 0 -16.3 0 -16 -16.4 01/20/2005 00:10:00 11.1 1.7 14.5 8.4 10.9 1.6 14.1 8 0.4 0 0.4 0.4 31 5 28 305 7 0 7 0 -16.3 0 -16 -16.6 01/20/2005 00:20:00 10.8 1.6 14.5 8 10.6 1.6 14.5 7.6 0.4 0 0.4 0.4 32 6 35 305 7 0 7 0 -16.3 0 -16 -16.6 01/20/2005 00:30:00 13.3 1.4 16.1 8.8 13 1.4 15.6 8.8 0.4 0 0.4 0.4 31 5 30 305 7 0 7 0 -16.4 0 -16.2 -16.6 01/20/2005 00:40:00 12.2 1.7 15.3 8.8 12.1 1.7 15.3 8 0.4 0 0.4 0.4 31 6 30 305 7 0 7 0 -16.4 0 -16.2 -16.6 01/20/2005 00:50:00 12 1.4 14.9 8.4 11.7 1.5 14.5 8 0.4 0 0.4 0.4 31 5 21 305 7 0 7 0 -16.4 0 -16 -16.6 01/20/2005 01:00:00 12 1.5 14.5 8.8 11.8 1.6 14.9 8.4 0.4 0 0.4 0.4 28 6 20 305 7 0 7 0 -16.4 0 -16.2 -16.6 01/20/2005 01:10:00 12.7 1.1 14.5 8.8 12.4 1.2 14.9 8.4 0.4 0 0.4 0.4 29 5 24 305 7 0 7 0 -16.5 0 -16.4 -16.6 01/20/2005 01:20:00 11.1 1.5 14.1 8.4 11 1.5 14.5 8 0.4 0 0.4 0.4 30 5 21 305 7 0 7 0 -16.5 0 -16.4 -16.6 01/20/2005 01:30:00 11.6 1.6 14.5 8.4 11.4 1.7 15.3 7.6 0.4 0 0.4 0.4 30 6 33 305 7 0 7 0 -16.5 0 -16.4 -16.6 01/20/2005 01:40:00 12.4 1.4 14.9 8.4 12.2 1.4 15.3 8 0.4 0 0.4 0.4 31 5 26 305 7 0 7 0 -16.6 0 -16.4 -16.7 01/20/2005 01:50:00 12.8 1.1 14.9 9.1 12.5 1.1 15.3 8.8 0.4 0 0.4 0.4 31 5 32 305 7 0 7 0 -16.7 0 -16.6 -16.9 01/20/2005 02:00:00 12.2 1.4 14.1 8.4 11.9 1.4 14.1 8.4 0.4 0 0.4 0.4 31 4 31 305 7 0 7 0 -16.7 0 -16.6 -16.9 01/20/2005 02:10:00 11.9 1.4 14.5 8.4 11.8 1.5 14.5 8 0.4 0 0.4 0.4 33 4 35 305 7 0 7 0 -16.8 0 -16.6 -16.9 01/20/2005 02:20:00 11.9 1.3 14.9 8.8 11.6 1.3 14.5 8.4 0.4 0 0.4 0.4 32 5 30 305 7 0 7 0 -16.8 0 -16.6 -16.9 01/20/2005 02:30:00 10.7 1.3 13.3 8 10.5 1.3 13.7 7.6 0.4 0 0.4 0.4 34 6 38 305 7 0 7 0 -16.8 0 -16.6 -16.9 01/20/2005 02:40:00 11.1 1.4 15.3 8.4 10.9 1.4 14.5 8.4 0.4 0 0.4 0.4 37 6 39 305 7 0 7 0 -16.7 0.1 -16.6 -16.9 01/20/2005 02:50:00 13 1.2 15.3 8.8 12.9 1.3 15.6 8.4 0.4 0 0.4 0.4 39 5 35 305 7 0 7 0 -16.8 0.1 -16.6 -16.9 01/20/2005 03:00:00 13 1.2 16.4 9.1 13 1.2 16.8 10.3 0.4 0 0.4 0.4 40 5 41 305 7 0 7 0 -16.8 0 -16.6 -16.9 01/20/2005 03:10:00 12 0.9 14.9 9.1 12.1 0.9 14.1 9.9 0.4 0 0.4 0.4 38 5 40 305 7 0 7 0 -16.8 0 -16.6 -16.9 01/20/2005 03:20:00 10.8 1.3 13.7 8.4 10.6 1.3 13.3 8 0.4 0 0.4 0.4 38 5 39 305 7 0 7 0 -16.9 0 -16.6 -16.9 01/20/2005 03:30:00 11.1 1.3 14.1 8.4 10.9 1.4 13.7 8.4 0.4 0 0.4 0.4 35 5 28 305 7 0 7 0 -16.9 0 -16.6 -16.9 01/20/2005 03:40:00 11.3 1.3 14.1 8.8 11.1 1.3 14.5 8.4 0.4 0 0.4 0.4 38 5 33 305 7 0 7 0 -16.9 0 -16.6 -16.9 01/20/2005 03:50:00 11.3 1.4 13.7 8.8 11.3 1.3 14.1 8.4 0.4 0 0.4 0.4 38 5 31 305 7 0 7 0 -16.9 0 -16.6 -16.9 01/20/2005 04:00:00 10.2 1.3 13 8 10.2 1.4 13 8 0.4 0 0.4 0.4 37 5 37 305 7 0 7 0 -16.9 0 -16.7 -16.9 01/20/2005 04:10:00 10.5 1.7 14.1 7.2 10.3 1.7 14.1 6.8 0.4 0 0.4 0.4 35 5 40 305 7 0 7 0 -16.9 0 -16.9 -16.9 01/20/2005 04:20:00 11.3 1.6 14.1 8.4 11.1 1.6 14.5 8 0.4 0 0.4 0.4 38 5 40 305 7 0 7 0 -16.9 0 -16.9 -17.1 01/20/2005 04:30:00 11.6 1.6 14.9 8.8 11.5 1.7 14.9 8.4 0.4 0 0.4 0.4 37 5 38 305 7 0 7 0 -17 0 -16.9 -17.1 01/20/2005 04:40:00 11.8 1.5 15.3 8.4 11.6 1.5 15.3 8.4 0.4 0 0.4 0.4 38 5 34 305 7 0 7 0 -17 0 -16.9 -17.1 01/20/2005 04:50:00 12.2 1.3 15.6 8.8 12 1.5 15.3 8.4 0.4 0 0.4 0.4 36 5 42 305 7 0 7 0 -17 0 -16.9 -17.1 01/20/2005 05:00:00 13.2 1.2 16.1 9.9 13 1.2 16.4 8.8 0.4 0 0.4 0.4 35 5 42 305 7 0 7 0 -17 0 -16.9 -17.1 01/20/2005 05:10:00 13.4 1.1 16.1 10.3 13 1.2 15.6 9.1 0.4 0 0.4 0.4 34 5 33 305 7 0 7 0 -17.1 0 -16.9 -17.3 01/20/2005 05:20:00 12.1 1.5 16.1 8.4 12 1.5 16.1 8.4 0.4 0 0.4 0.4 36 6 32 305 7 0 7 0 -17.1 0 -16.9 -17.3 01/20/2005 05:30:00 11.8 1.1 14.5 8.4 11.7 1.2 14.1 8.4 0.4 0 0.4 0.4 35 5 35 305 7 0 7 0 -17.2 0 -16.9 -17.3 01/20/2005 05:40:00 12.3 1.1 14.5 8.8 12.1 1.2 15.3 8.4 0.4 0 0.4 0.4 36 5 32 305 7 0 7 0 -17.3 0.1 -16.9 -17.5 01/20/2005 05:50:00 12 1.3 14.5 8.8 11.8 1.5 14.9 8.4 0.4 0 0.4 0.4 35 5 35 305 7 0 7 0 -17.4 0 -17.3 -17.5 01/20/2005 06:00:00 11.9 1.6 14.9 8.4 11.7 1.6 14.9 8.4 0.4 0 0.4 0.4 37 5 33 305 7 0 7 0 -17.4 0 -17.1 -17.5 01/20/2005 06:10:00 12.4 1.2 15.6 9.1 12.2 1.3 15.6 8.4 0.4 0 0.4 0.4 37 5 37 305 7 0 7 0 -17.5 0 -17.3 -17.5 01/20/2005 06:20:00 11.7 1.7 14.9 8.4 11.5 1.7 14.9 8 0.4 0 0.4 0.4 36 6 28 305 7 0 7 0 -17.5 0 -17.3 -17.5 01/20/2005 06:30:00 11.6 1.2 15.3 8.4 11.6 1.4 14.5 8.4 0.4 0 0.4 0.4 37 5 35 305 7 0 7 0 -17.5 0 -17.5 -17.7 01/20/2005 06:40:00 11.8 1.3 14.5 8.8 11.5 1.4 14.5 8.4 0.4 0 0.4 0.4 35 5 40 305 7 0 7 0 -17.5 0 -17.5 -17.7 01/20/2005 06:50:00 12.5 1.4 15.6 8.8 12.2 1.5 15.3 8.4 0.4 0 0.4 0.4 35 5 35 305 7 0 7 0 -17.5 0 -17.5 -17.7 01/20/2005 07:00:00 11.5 1.4 15.3 8.4 11.3 1.3 14.5 8.4 0.4 0 0.4 0.4 35 5 33 305 7 0 7 0 -17.5 0 -17.5 -17.7 01/20/2005 07:10:00 12 1.4 14.5 8.4 11.6 1.5 14.9 7.6 0.4 0 0.4 0.4 35 5 37 305 7 0 7 0 -17.5 0 -17.5 -17.7 01/20/2005 07:20:00 10.9 1.5 14.9 8.4 10.7 1.4 14.1 7.6 0.4 0 0.4 0.4 36 6 35 305 7 0 7 0 -17.6 0 -17.5 -17.7 01/20/2005 07:30:00 11 1.5 14.1 8.4 10.8 1.7 14.1 8 0.4 0 0.4 0.4 38 5 40 305 7 0 7 0 -17.6 0 -17.5 -17.7 01/20/2005 07:40:00 11.1 1.7 14.5 8 11 1.9 14.9 7.6 0.4 0 0.4 0.4 37 6 35 305 7 0 7 0 -17.6 0 -17.5 -17.7 01/20/2005 07:50:00 12.4 1.1 14.9 8.8 12.3 1.1 15.3 8.4 0.4 0 0.4 0.4 36 5 40 305 7 0 7 0 -17.6 0 -17.5 -17.9 01/20/2005 08:00:00 11.2 1.7 14.5 8 10.9 1.7 14.9 8.4 0.4 0 0.4 0.4 36 6 41 305 7 0 7 0 -17.7 0 -17.5 -17.9 01/20/2005 08:10:00 11 1.7 14.9 8.4 10.8 1.6 14.5 8 0.4 0 0.4 0.4 37 5 40 305 7 0 7 0 -17.7 0 -17.5 -17.9 01/20/2005 08:20:00 10 1.3 13 8 9.9 1.3 13 7.6 0.4 0 0.4 0.4 34 6 36 305 7 0 7 0 -17.8 0 -17.5 -17.9 01/20/2005 08:30:00 9.8 1.3 13 7.6 9.6 1.4 13 7.2 0.4 0 0.4 0.4 35 6 32 305 7 0 7 0 -17.8 0 -17.7 -18.1 01/20/2005 08:40:00 9.9 1.3 13 7.6 9.9 1.4 13.3 7.2 0.4 0 0.4 0.4 37 5 33 305 7 0 7 0 -17.8 0 -17.5 -18.1 01/20/2005 08:50:00 10.6 1.3 13.3 8 10.4 1.5 14.1 8 0.4 0 0.4 0.4 36 5 30 305 7 0 7 0 -17.9 0 -17.7 -18.1 01/20/2005 09:00:00 10.3 1.2 13 8 10.1 1.3 13 8 0.4 0 0.4 0.4 37 6 35 305 7 0 7 0 -17.9 0 -17.7 -18.1 01/20/2005 09:10:00 10.7 1.3 13.3 8 10.5 1.3 12.6 7.6 0.4 0 0.4 0.4 35 5 35 305 7 0 7 0 -17.9 0 -17.7 -18.1 01/20/2005 09:20:00 9.8 1.3 13 7.2 9.8 1.3 13 7.6 0.4 0 0.4 0.4 38 6 31 305 7 0 6 0 -17.9 0 -17.7 -18.1 01/20/2005 09:30:00 9.3 1 12.6 7.6 9.1 1 11.8 7.6 0.4 0 0.4 0.4 36 6 32 305 6 0 6 0 -18 0 -17.9 -18.1 01/20/2005 09:40:00 10.9 1.2 13.3 8.8 10.8 1.3 13.3 8 0.4 0 0.4 0.4 38 6 36 305 6 0 6 0 -18 0 -17.9 -18.1 01/20/2005 09:50:00 9.4 1.3 12.6 6.8 9.3 1.4 13 6.5 0.4 0 0.4 0.4 38 7 36 305 6 0 6 0 -18 0 -17.9 -18.1 01/20/2005 10:00:00 9.3 1 12.2 7.2 9.1 1 12.2 7.2 0.4 0 0.4 0.4 37 6 30 305 6 0 6 0 -18 0 -17.9 -18.1 01/20/2005 10:10:00 9.7 1.4 13 7.6 9.5 1.3 13.3 7.2 0.4 0 0.4 0.4 38 6 38 305 6 0 6 0 -18 0 -17.9 -18.1 01/20/2005 10:20:00 10.2 1.2 13 7.6 10.1 1.3 13.3 7.2 0.4 0 0.4 0.4 36 5 37 305 6 0 6 0 -18 0 -17.9 -18.1 01/20/2005 10:30:00 9.1 1 12.2 6.8 8.9 1.1 12.2 6.8 0.4 0 0.4 0.4 31 6 36 305 6 0 6 0 -17.9 0 -17.9 -18.1 01/20/2005 10:40:00 10.5 1.5 13 7.2 10.3 1.5 13.3 6.8 0.4 0 0.4 0.4 31 5 32 305 6 0 6 0 -17.9 0 -17.5 -18.1 01/20/2005 10:50:00 9.4 1.2 12.6 6.8 9.2 1.2 13 7.2 0.4 0 0.4 0.4 30 7 27 305 6 0 6 0 -18 0 -17.5 -18.1 01/20/2005 11:00:00 9.7 1.5 13 6.5 9.5 1.6 13.3 6.5 0.4 0 0.4 0.4 31 6 41 305 6 0 6 0 -18 0 -17.9 -18.1 01/20/2005 11:10:00 9.5 1.3 13 6.8 9.4 1.3 13 6.5 0.4 0 0.4 0.4 31 6 27 305 6 0 6 0 -18 0 -17.7 -18.1 01/20/2005 11:20:00 9.1 0.9 11.8 6.8 9 1.1 12.2 7.2 0.4 0 0.4 0.4 26 6 27 305 6 0 6 0 -17.9 0.1 -17.7 -18.1 01/20/2005 11:30:00 9.4 1.3 12.2 6.1 9.1 1.4 12.2 6.1 0.4 0 0.4 0.4 26 6 26 305 7 0 6 0 -17.8 0 -17.5 -18.1 01/20/2005 11:40:00 8.9 1 11.5 6.1 8.8 1.1 11.8 6.1 0.4 0 0.4 0.4 32 6 40 305 7 0 7 0 -17.8 0 -17.5 -18.1 01/20/2005 11:50:00 9.2 1.2 12.6 7.2 9 1.2 12.6 6.5 0.4 0 0.4 0.4 35 5 37 305 7 0 7 0 -17.8 0 -17.7 -18.1 01/20/2005 12:00:00 9.4 1.2 12.6 6.8 9.2 1.3 12.6 6.1 0.4 0 0.4 0.4 33 5 38 305 7 0 7 0 -17.8 0 -17.5 -18.1 01/20/2005 12:10:00 10 1.2 13 7.6 9.9 1.3 12.6 7.6 0.4 0 0.4 0.4 32 5 30 305 7 0 7 0 -17.8 0 -17.5 -18.1 01/20/2005 12:20:00 10.1 1.3 13.3 8.4 9.9 1.3 13.3 7.6 0.4 0 0.4 0.4 34 5 30 305 7 0 7 0 -17.8 0 -17.5 -17.9 01/20/2005 12:30:00 10.4 1.2 13 8.4 10.2 1.3 13 8 0.4 0 0.4 0.4 33 5 33 305 7 0 7 0 -17.7 0 -17.5 -17.9 01/20/2005 12:40:00 9.6 1.2 12.6 7.2 9.3 1.2 12.6 7.2 0.4 0 0.4 0.4 31 5 31 305 7 0 7 0 -17.5 0 -17.3 -17.7 01/20/2005 12:50:00 9 0.9 12.2 7.2 8.9 1 11.8 7.2 0.4 0 0.4 0.4 34 5 30 305 7 0 7 0 -17.4 0 -17.1 -17.5 01/20/2005 13:00:00 10.3 1.2 13 8 10.2 1.3 13.3 8 0.4 0 0.4 0.4 33 5 31 305 7 0 7 0 -17.3 0 -16.9 -17.5 01/20/2005 13:10:00 9.9 1.2 12.6 7.6 9.9 1.3 13 7.6 0.4 0 0.4 0.4 31 5 29 305 8 0 8 0 -17.1 0 -16.9 -17.3 01/20/2005 13:20:00 10.2 1.2 13 8 10.2 1.3 13 8 0.4 0 0.4 0.4 31 5 32 305 8 0 8 0 -17 0 -16.9 -17.1 01/20/2005 13:30:00 9.3 1 12.2 7.2 9.2 1.1 11.8 6.5 0.4 0 0.4 0.4 32 5 23 305 8 0 8 0 -16.9 0 -16.6 -16.9 01/20/2005 13:40:00 9.2 0.9 11.8 7.2 9.2 1 11.8 7.2 0.4 0 0.4 0.4 32 5 36 305 8 0 8 0 -16.9 0 -16.6 -16.9 01/20/2005 13:50:00 8.8 0.7 11.5 6.5 8.7 1 11.8 6.5 0.4 0 0.4 0.4 31 5 27 305 8 0 8 0 -16.8 0 -16.4 -16.9 01/20/2005 14:00:00 8.6 0.7 11.1 6.8 8.5 0.7 10.7 6.8 0.4 0 0.4 0.4 35 6 31 305 9 0 9 0 -16.7 0.1 -16.4 -16.9 01/20/2005 14:10:00 8.5 1.1 11.8 5.3 8.3 1 11.5 6.1 0.4 0 0.4 0.4 36 6 36 305 10 0 10 0 -16.6 0 -16.2 -16.9 01/20/2005 14:20:00 8.2 0.8 11.1 6.5 8.1 0.8 11.1 6.1 0.4 0 0.4 0.4 40 6 39 305 10 0 10 0 -16.6 0.1 -16.2 -16.9 01/20/2005 14:30:00 9 1 11.8 6.8 8.9 1.1 12.2 6.5 0.4 0 0.4 0.4 43 6 44 305 10 0 10 0 -16.7 0.1 -16.4 -16.9 01/20/2005 14:40:00 8.7 0.8 11.1 6.1 8.6 1 11.8 6.1 0.4 0 0.4 0.4 40 6 42 305 9 0 9 0 -16.7 0.1 -16.4 -16.9 01/20/2005 14:50:00 8.6 0.6 11.8 6.5 8.5 0.7 11.5 6.5 0.4 0 0.4 0.4 39 5 33 305 9 0 9 0 -16.6 0.1 -16.4 -16.9 01/20/2005 15:00:00 8.9 0.9 11.8 6.8 8.8 1 11.5 6.8 0.4 0 0.4 0.4 37 6 35 305 9 0 9 0 -16.6 0.1 -16.2 -16.9 01/20/2005 15:10:00 8.6 0.9 11.5 6.1 8.4 0.9 11.8 6.1 0.4 0 0.4 0.4 37 6 41 305 9 0 9 0 -16.6 0 -16.2 -16.9 01/20/2005 15:20:00 9 1 12.2 6.5 8.8 1 11.8 6.5 0.4 0 0.4 0.4 38 6 26 305 9 0 8 0 -16.7 0.1 -16.2 -16.9 01/20/2005 15:30:00 8.5 0.5 9.1 6.8 8.3 0.6 10.7 6.8 0.4 0 0.4 0.4 38 5 39 305 8 0 8 0 -16.7 0.1 -16.4 -16.9 01/20/2005 15:40:00 8.6 0.7 11.5 6.5 8.6 1 11.5 6.5 0.4 0 0.4 0.4 39 5 40 305 8 0 8 0 -16.9 0 -16.4 -16.9 01/20/2005 15:50:00 8.8 0.8 11.1 6.1 8.7 1 11.5 6.5 0.4 0 0.4 0.4 41 6 36 305 8 0 8 0 -17 0 -16.6 -17.1 01/20/2005 16:00:00 8.7 0.6 11.1 6.8 8.6 0.8 11.5 6.5 0.4 0 0.4 0.4 42 5 41 305 7 0 7 0 -16.9 0 -16.6 -16.9 01/20/2005 16:10:00 8.4 0.8 11.5 6.1 8.3 0.8 11.1 6.1 0.4 0 0.4 0.4 41 6 37 305 7 0 7 0 -16.9 0 -16.6 -16.9 01/20/2005 16:20:00 8.7 0.7 11.5 6.1 8.6 0.8 11.5 6.5 0.4 0 0.4 0.4 42 6 39 305 7 0 7 0 -17 0 -16.7 -17.1 01/20/2005 16:30:00 8.4 0.7 10.7 6.8 8.2 0.7 10.7 6.5 0.4 0 0.4 0.4 39 6 48 305 7 0 7 0 -17 0 -16.9 -17.1 01/20/2005 16:40:00 8.1 0.7 9.5 6.5 7.9 0.7 8.8 5.7 0.4 0 0.4 0.4 41 5 32 305 7 0 7 0 -17.1 0 -16.9 -17.3 01/20/2005 16:50:00 8.2 1 9.5 5.3 8.1 1 10.7 5.3 0.4 0 0.4 0.4 40 6 40 305 7 0 7 0 -17.1 0 -16.9 -17.3 01/20/2005 17:00:00 8.2 0.7 10.7 6.5 8 0.8 9.9 5.3 0.4 0 0.4 0.4 38 6 42 305 6 0 7 0 -17.3 0.1 -16.9 -17.5 01/20/2005 17:10:00 8.1 1 10.7 5.3 8 1 10.7 5.3 0.4 0 0.4 0.4 36 6 39 305 6 0 6 0 -17.2 0.1 -16.9 -17.5 01/20/2005 17:20:00 8.5 0.6 9.5 6.8 8.3 0.8 11.1 6.1 0.4 0 0.4 0.4 36 6 41 305 6 0 6 0 -17.2 0 -16.9 -17.3 01/20/2005 17:30:00 8.4 0.8 9.5 5.7 8.4 0.9 11.1 6.1 0.4 0 0.4 0.4 34 6 38 305 6 0 6 0 -17.1 0 -16.9 -17.3 01/20/2005 17:40:00 8.3 1 11.5 5.3 8.1 1.1 11.8 5.7 0.4 0 0.4 0.4 32 7 33 305 6 0 6 0 -17 0 -16.9 -17.1 01/20/2005 17:50:00 8.1 0.7 9.5 5.7 8 0.7 10.3 5.7 0.4 0 0.4 0.4 34 6 30 305 7 0 7 0 -17 0 -16.9 -17.1 01/20/2005 18:00:00 8.1 1 11.1 5.7 8 1.2 11.5 5.7 0.4 0 0.4 0.4 32 7 28 305 7 0 7 0 -17 0 -16.9 -17.1 01/20/2005 18:10:00 8.4 0.8 11.1 6.1 8.2 0.8 10.7 5.7 0.4 0 0.4 0.4 32 6 30 305 7 0 7 0 -16.9 0 -16.7 -17.1 01/20/2005 18:20:00 8.7 0.8 11.5 6.5 8.5 1 11.8 5.7 0.4 0 0.4 0.4 36 6 37 305 7 0 7 0 -16.9 0 -16.6 -16.9 01/20/2005 18:30:00 9.2 1.3 12.2 6.5 9 1.3 13 6.1 0.4 0 0.4 0.4 34 6 32 305 7 0 7 0 -16.8 0.1 -16.6 -16.9 01/20/2005 18:40:00 9.2 0.9 11.8 6.1 9.2 1.1 12.2 6.5 0.4 0 0.4 0.4 33 6 35 305 7 0 7 0 -16.7 0 -16.4 -16.9 01/20/2005 18:50:00 9.6 1 12.2 8 9.4 1.1 11.8 7.6 0.4 0 0.4 0.4 33 5 32 305 7 0 7 0 -16.7 0 -16.4 -16.9 01/20/2005 19:00:00 8.9 1.4 12.6 6.1 8.7 1.5 12.2 5.7 0.4 0 0.4 0.4 38 6 40 305 7 0 7 0 -16.7 0.1 -16.4 -16.9 01/20/2005 19:10:00 9 1.1 11.8 5.7 8.8 1.2 12.2 5.7 0.4 0 0.4 0.4 37 6 39 305 7 0 8 0 -16.7 0 -16.4 -16.9 01/20/2005 19:20:00 7.9 1.1 11.1 4.9 7.7 1.1 10.7 4.9 0.4 0 0.4 0.4 39 7 45 305 8 0 8 0 -16.7 0 -16.4 -16.9 01/20/2005 19:30:00 8.8 0.8 11.1 6.5 8.6 0.8 11.1 6.1 0.4 0 0.4 0.4 37 7 41 305 7 0 7 0 -16.7 0.1 -16.4 -16.9 01/20/2005 19:40:00 8.7 0.7 11.1 6.1 8.5 1 11.1 6.1 0.4 0 0.4 0.4 33 6 37 305 7 0 7 0 -16.7 0 -16.4 -16.9 01/20/2005 19:50:00 9.3 1 12.2 6.5 9.1 1.1 11.8 6.5 0.4 0 0.4 0.4 33 6 34 305 8 0 7 0 -16.7 0 -16.4 -16.9 01/20/2005 20:00:00 8.9 1 11.8 6.5 8.6 1 11.8 6.5 0.4 0 0.4 0.4 33 6 32 305 8 0 8 0 -16.5 0 -16.4 -16.6 01/20/2005 20:10:00 9.8 1.1 12.2 7.6 9.7 1.2 12.6 7.6 0.4 0 0.4 0.4 33 6 32 305 8 0 8 0 -16.4 0 -16.2 -16.6 01/20/2005 20:20:00 8.8 1 11.5 6.1 8.6 1.1 11.5 5.3 0.4 0 0.4 0.4 36 6 37 305 8 0 8 0 -16.3 0 -16.2 -16.6 01/20/2005 20:30:00 9.2 1.3 11.8 5.7 9.1 1.4 12.2 6.5 0.4 0 0.4 0.4 38 6 34 305 8 0 8 0 -16.3 0 -16 -16.4 01/20/2005 20:40:00 9 1 11.5 6.5 8.9 1.1 12.2 6.1 0.4 0 0.4 0.4 38 6 36 305 8 0 8 0 -16.1 0 -16 -16.2 01/20/2005 20:50:00 9.1 0.9 11.5 7.2 8.8 0.9 11.5 6.5 0.4 0 0.4 0.4 41 6 32 305 8 0 8 0 -15.8 0 -15.6 -16 01/20/2005 21:00:00 9.9 1.3 12.2 7.2 9.6 1.2 12.2 7.2 0.4 0 0.4 0.4 38 6 37 305 8 0 8 0 -15.8 0 -15.6 -16 01/20/2005 21:10:00 9.2 0.9 12.2 7.2 9.1 1 11.8 7.2 0.4 0 0.4 0.4 38 5 36 305 9 0 8 0 -15.8 0 -15.4 -15.8 01/20/2005 21:20:00 10.9 1.3 13 8.4 10.8 1.4 13.3 8 0.4 0 0.4 0.4 40 5 38 305 9 0 8 0 -15.8 0 -15.4 -16 01/20/2005 21:30:00 10.4 1.3 13.3 8 10.1 1.4 13.3 7.2 0.4 0 0.4 0.4 42 5 40 305 9 0 9 0 -15.8 0 -15.4 -16 01/20/2005 21:40:00 10.9 1.5 13.7 8 10.6 1.5 13.7 7.6 0.4 0 0.4 0.4 44 5 42 305 9 0 9 0 -15.8 0 -15.4 -15.8 01/20/2005 21:50:00 11.7 0.9 13.3 8.8 11.7 0.9 13.3 8.4 0.4 0 0.4 0.4 45 4 46 305 9 0 9 0 -15.8 0 -15.4 -15.8 01/20/2005 22:00:00 10.6 1.2 13 8 10.5 1.3 13.3 8 0.4 0 0.4 0.4 42 5 41 305 9 0 9 0 -15.8 0 -15.2 -16 01/20/2005 22:10:00 9.6 1 12.2 7.6 9.3 1 12.2 7.2 0.4 0 0.4 0.4 36 6 32 305 9 0 9 0 -15.6 0.1 -15.2 -15.8 01/20/2005 22:20:00 9.5 0.9 11.5 8 9.6 1 11.8 7.2 0.4 0 0.4 0.4 35 5 37 305 9 0 9 0 -15.7 0.1 -15.2 -15.8 01/20/2005 22:30:00 8.8 0.8 11.5 6.5 8.7 0.8 11.5 6.8 0.4 0 0.4 0.4 34 6 28 305 9 0 9 0 -15.7 0.1 -15.2 -15.8 01/20/2005 22:40:00 9.3 1 11.8 6.5 9.3 1.1 11.8 6.5 0.4 0 0.4 0.4 34 5 35 305 9 0 9 0 -15.8 0 -15.4 -15.8 01/20/2005 22:50:00 9.1 0.8 11.8 7.2 9 1 11.1 6.5 0.4 0 0.4 0.4 36 6 24 305 9 0 9 0 -15.8 0 -15.6 -16 01/20/2005 23:00:00 9 0.7 11.5 7.2 8.9 0.8 11.5 7.2 0.4 0 0.4 0.4 35 6 44 305 9 0 8 0 -15.8 0 -15.6 -16 01/20/2005 23:10:00 9 0.8 11.8 7.2 8.9 0.9 12.2 7.6 0.4 0 0.4 0.4 36 6 46 305 9 0 9 0 -15.8 0 -15.6 -16 01/20/2005 23:20:00 9.2 1.1 11.5 6.8 9.1 1.1 11.8 6.8 0.4 0 0.4 0.4 39 5 38 305 9 0 9 0 -15.9 0 -15.6 -16 01/20/2005 23:30:00 8.5 1.3 12.2 5.7 8.4 1.2 12.6 6.1 0.4 0 0.4 0.4 39 5 32 305 9 0 9 0 -15.9 0 -15.6 -16 01/20/2005 23:40:00 8.5 0.8 11.1 6.5 8.4 0.8 11.1 6.5 0.4 0 0.4 0.4 40 6 40 305 9 0 9 0 -15.8 0 -15.6 -16 01/20/2005 23:50:00 9.7 1.2 12.6 8 9.6 1.2 12.6 7.6 0.4 0 0.4 0.4 39 6 31 305 9 0 9 0 -15.9 0 -15.6 -16 01/21/2005 00:00:00 9.1 1 12.6 6.5 9 1.1 13 6.5 0.4 0 0.4 0.4 40 7 27 305 9 0 9 0 -15.9 0 -15.6 -16 01/21/2005 00:10:00 10.5 1.3 13 6.8 10.3 1.3 13 7.2 0.4 0 0.4 0.4 37 6 27 305 9 0 9 0 -16 0 -15.6 -16 01/21/2005 00:20:00 10.1 1.4 13.3 7.2 9.9 1.5 13.7 7.2 0.4 0 0.4 0.4 36 6 43 305 9 0 9 0 -15.9 0 -15.6 -16.2 01/21/2005 00:30:00 10.9 1.5 13.7 7.6 10.6 1.5 13.7 7.6 0.4 0 0.4 0.4 40 5 42 305 9 0 8 0 -16.1 0 -15.8 -16.2 01/21/2005 00:40:00 11.3 1.5 13.7 8 11.1 1.5 14.5 7.2 0.4 0 0.4 0.4 39 5 39 305 8 0 8 0 -16.1 0.1 -15.8 -16.4 01/21/2005 00:50:00 10.1 1.2 13 8 9.9 1.2 12.6 7.6 0.4 0 0.4 0.4 32 6 33 305 8 0 8 0 -16.4 0.1 -15.8 -16.7 01/21/2005 01:00:00 10.5 1.2 13 8.4 10.5 1.2 13 8.4 0.4 0 0.4 0.4 32 4 32 305 8 0 8 0 -16.8 0.1 -16.4 -16.9 01/21/2005 01:10:00 10.1 1.2 12.6 8 10 1.3 12.6 8 0.4 0 0.4 0.4 29 5 25 305 8 0 8 0 -16.9 0 -16.6 -17.1 01/21/2005 01:20:00 10.1 1.4 13.3 8 9.9 1.4 13.3 7.6 0.4 0 0.4 0.4 31 5 29 305 8 0 8 0 -17 0 -16.9 -17.3 01/21/2005 01:30:00 10.4 1.5 13.3 7.2 10.4 1.5 13.3 7.6 0.4 0 0.4 0.4 34 6 32 305 8 0 8 0 -16.9 0 -16.6 -16.9 01/21/2005 01:40:00 9.4 1.3 13 6.8 9.3 1.4 13.3 6.5 0.4 0 0.4 0.4 34 6 33 305 8 0 8 0 -16.9 0 -16.6 -16.9 01/21/2005 01:50:00 10.2 1.2 13 8 10 1.3 13 7.6 0.4 0 0.4 0.4 29 5 31 305 8 0 8 0 -17 0 -16.9 -17.1 01/21/2005 02:00:00 11.2 1.4 13.3 8 11.2 1.4 14.1 7.6 0.4 0 0.4 0.4 34 5 35 305 8 0 8 0 -17.1 0 -16.9 -17.3 01/21/2005 02:10:00 11.5 1.1 13.7 8.4 11.6 1 13.7 8.4 0.4 0 0.4 0.4 37 5 38 305 8 0 8 0 -17 0 -16.9 -17.3 01/21/2005 02:20:00 11.5 1.6 14.1 8 11.4 1.6 14.1 8 0.4 0 0.4 0.4 36 6 33 305 8 0 8 0 -17.1 0 -16.9 -17.3 01/21/2005 02:30:00 11.9 1 14.1 8.8 11.7 1.1 14.5 8.4 0.4 0 0.4 0.4 36 5 33 305 8 0 8 0 -17 0 -16.9 -17.1 01/21/2005 02:40:00 11.9 0.9 14.1 8.8 12 1 14.1 8.4 0.4 0 0.4 0.4 35 5 37 305 8 0 8 0 -17.3 0.1 -16.9 -17.5 01/21/2005 02:50:00 11.6 1.3 14.1 8.4 11.6 1.4 14.1 8.4 0.4 0 0.4 0.4 35 5 30 305 7 0 7 0 -17.4 0 -17.1 -17.5 01/21/2005 03:00:00 11.4 1.1 13.3 8.8 11.5 1.1 13.7 8.4 0.4 0 0.4 0.4 35 5 29 305 7 0 7 0 -17.5 0 -17.3 -17.7 01/21/2005 03:10:00 10.2 1.3 13 7.6 10.3 1.3 13 7.6 0.4 0 0.4 0.4 32 6 19 305 7 0 7 0 -17.5 0.1 -17.3 -17.9 01/21/2005 03:20:00 11.1 1.2 13.3 8 11.1 1.2 13.7 8.4 0.4 0 0.4 0.4 34 5 43 305 7 0 7 0 -17.7 0 -17.5 -17.9 01/21/2005 03:30:00 9.9 1.5 13.7 6.5 9.9 1.6 13.3 6.5 0.4 0 0.4 0.4 37 6 32 305 7 0 7 0 -17.7 0 -17.5 -17.9 01/21/2005 03:40:00 8.9 0.8 11.5 7.2 9 1 11.8 6.8 0.4 0 0.4 0.4 33 7 33 305 7 0 7 0 -17.7 0 -17.5 -17.9 01/21/2005 03:50:00 9.8 1.7 13.7 7.2 9.8 1.7 13.3 6.8 0.4 0 0.4 0.4 37 6 41 305 7 0 7 0 -17.6 0 -17.5 -17.9 01/21/2005 04:00:00 9.3 1.2 12.2 6.5 9.3 1.3 12.6 6.8 0.4 0 0.4 0.4 34 6 39 305 7 0 7 0 -17.5 0 -17.3 -17.7 01/21/2005 04:10:00 9 1 12.6 6.5 8.9 1.1 13 6.8 0.4 0 0.4 0.4 35 7 46 305 7 0 7 0 -17.5 0 -17.3 -17.7 01/21/2005 04:20:00 8.9 0.9 12.2 6.8 8.7 1 13 6.5 0.4 0 0.4 0.4 33 6 32 305 7 0 7 0 -17.5 0 -17.3 -17.7 01/21/2005 04:30:00 9 1.2 12.6 6.5 8.9 1.3 13 6.5 0.4 0 0.4 0.4 33 7 36 305 7 0 7 0 -17.5 0 -17.3 -17.7 01/21/2005 04:40:00 9.2 1.3 12.2 6.1 9.2 1.3 12.2 6.1 0.4 0 0.4 0.4 33 7 39 305 7 0 7 0 -17.6 0 -17.3 -17.9 01/21/2005 04:50:00 9.2 1.3 12.2 6.1 9.2 1.3 12.6 6.5 0.4 0 0.4 0.4 31 6 29 305 7 0 7 0 -17.6 0 -17.5 -17.9 01/21/2005 05:00:00 8.6 0.8 11.1 6.5 8.6 0.9 11.5 6.1 0.4 0 0.4 0.4 26 6 26 305 7 0 7 0 -17.5 0 -17.3 -17.5 01/21/2005 05:10:00 8.2 0.7 10.3 6.5 8.1 0.6 10.7 6.5 0.4 0 0.4 0.4 23 5 33 305 7 0 7 0 -17.5 0 -17.1 -17.5 01/21/2005 05:20:00 8.3 0.8 11.5 6.5 8.2 0.8 11.1 5.7 0.4 0 0.4 0.4 24 6 26 305 7 0 7 0 -17.4 0 -16.9 -17.5 01/21/2005 05:30:00 8.3 0.6 9.1 6.8 8.2 0.5 9.9 6.5 0.4 0 0.4 0.4 19 5 18 305 7 0 7 0 -17.3 0.1 -16.9 -17.5 01/21/2005 05:40:00 8.1 0.6 9.1 6.5 8 0.6 8.8 6.1 0.4 0 0.4 0.4 18 4 18 305 7 0 7 0 -17.2 0 -16.9 -17.3 01/21/2005 05:50:00 8.1 0.6 9.5 6.5 8.1 0.5 10.3 6.5 0.4 0 0.4 0.4 19 4 17 305 7 0 7 0 -17.1 0.1 -16.9 -17.3 01/21/2005 06:00:00 9.1 1 11.8 6.5 9.1 1.1 12.2 6.8 0.4 0 0.4 0.4 24 5 22 305 7 0 7 0 -16.8 0 -16.6 -16.9 01/21/2005 06:10:00 8.7 0.5 10.7 6.8 8.7 0.7 11.1 6.8 0.4 0 0.4 0.4 25 6 28 305 8 0 8 0 -16.7 0.1 -16.2 -16.9 01/21/2005 06:20:00 8 0.6 9.1 6.1 7.9 0.6 8.8 6.1 0.4 0 0.4 0.4 18 4 18 305 8 0 8 0 -16.7 0.1 -16.4 -16.9 01/21/2005 06:30:00 7.8 0.9 11.8 5.7 7.7 0.9 11.1 5.7 0.4 0 0.4 0.4 21 6 37 305 8 0 8 0 -16.7 0.2 -16 -16.9 01/21/2005 06:40:00 9.1 0.8 11.8 7.6 9.1 1 12.2 7.2 0.4 0 0.4 0.4 33 5 38 305 8 0 8 0 -16.2 0.1 -16 -16.6 01/21/2005 06:50:00 10.3 1.2 13 7.2 10.1 1.3 13 7.2 0.4 0 0.4 0.4 30 4 33 305 8 0 8 0 -16.3 0 -16 -16.6 01/21/2005 07:00:00 10 1.3 13.3 8 9.8 1.3 13.3 8 0.4 0 0.4 0.4 33 6 36 305 8 0 8 0 -16.3 0 -16 -16.6 01/21/2005 07:10:00 8.7 0.5 11.5 6.1 8.5 0.6 11.8 6.5 0.4 0 0.4 0.4 29 5 32 305 8 0 8 0 -16.6 0 -16.4 -16.9 01/21/2005 07:20:00 8.8 0.6 11.5 6.8 8.7 0.7 11.5 7.2 0.4 0 0.4 0.4 32 5 32 305 8 0 8 0 -16.7 0.1 -16.6 -16.9 01/21/2005 07:30:00 10.1 1.1 12.6 8 10 1.2 12.6 7.6 0.4 0 0.4 0.4 38 6 43 305 8 0 8 0 -16.5 0.1 -16.2 -16.9 01/21/2005 07:40:00 10 1.1 12.2 7.2 9.9 1.1 11.8 7.2 0.4 0 0.4 0.4 32 5 34 305 8 0 8 0 -16.5 0 -16.4 -16.6 01/21/2005 07:50:00 9.5 0.9 12.2 8 9.4 1.1 11.8 7.6 0.4 0 0.4 0.4 32 5 34 305 8 0 8 0 -16.5 0 -16.4 -16.6 01/21/2005 08:00:00 10 1.1 12.2 8 9.9 1.2 12.6 7.6 0.4 0 0.4 0.4 31 5 26 305 8 0 8 0 -16.5 0 -16.2 -16.6 01/21/2005 08:10:00 9.3 1.1 11.8 6.8 9.2 1.2 11.8 6.8 0.4 0 0.4 0.4 33 5 27 305 8 0 8 0 -16.5 0 -16.2 -16.6 01/21/2005 08:20:00 9.9 1.2 12.6 7.2 9.9 1.3 13.3 7.2 0.4 0 0.4 0.4 33 5 35 305 8 0 8 0 -16.5 0 -16.2 -16.6 01/21/2005 08:30:00 9.5 1.2 13 7.2 9.3 1.2 12.6 6.8 0.4 0 0.4 0.4 32 5 31 305 8 0 8 0 -16.6 0 -16.4 -16.6 01/21/2005 08:40:00 10.3 1.3 13 7.6 10.3 1.4 13.3 7.2 0.4 0 0.4 0.4 34 5 32 305 8 0 8 0 -16.6 0 -16.4 -16.7 01/21/2005 08:50:00 9.7 1.2 12.2 7.6 9.5 1.2 12.6 7.2 0.4 0 0.4 0.4 32 6 35 305 8 0 8 0 -16.7 0 -16.4 -16.9 01/21/2005 09:00:00 10.1 1.3 13 6.8 10 1.4 13 7.2 0.4 0 0.4 0.4 34 5 37 305 8 0 8 0 -16.7 0 -16.6 -16.9 01/21/2005 09:10:00 10.6 1 12.6 8.4 10.3 1.1 12.6 8 0.4 0 0.4 0.4 37 5 42 305 8 0 8 0 -16.8 0.1 -16.6 -16.9 01/21/2005 09:20:00 9.7 1.2 12.6 7.6 9.7 1.2 13 7.2 0.4 0 0.4 0.4 36 6 40 305 8 0 8 0 -16.8 0 -16.6 -16.9 01/21/2005 09:30:00 11.1 1.3 13.7 7.2 11 1.3 14.1 7.6 0.4 0 0.4 0.4 35 5 37 305 8 0 8 0 -16.9 0 -16.6 -16.9 01/21/2005 09:40:00 11.2 1.4 13.7 7.6 11 1.4 13.7 8.4 0.4 0 0.4 0.4 38 5 45 305 8 0 8 0 -16.9 0 -16.6 -16.9 01/21/2005 09:50:00 10.8 1.7 13.7 7.6 10.6 1.8 14.1 7.2 0.4 0 0.4 0.4 38 5 34 305 8 0 7 0 -16.9 0 -16.6 -16.9 01/21/2005 10:00:00 11.1 1.2 13.3 8 10.8 1.4 13.7 8 0.4 0 0.4 0.4 37 6 44 305 8 0 8 0 -16.9 0 -16.6 -16.9 01/21/2005 10:10:00 11 1.1 13.3 8.4 10.8 1.2 13 8 0.4 0 0.4 0.4 39 5 38 305 8 0 8 0 -16.9 0 -16.9 -17.1 01/21/2005 10:20:00 10.6 1.3 13 7.2 10.3 1.4 13 6.8 0.4 0 0.4 0.4 37 5 32 305 7 0 7 0 -17 0 -16.9 -17.1 01/21/2005 10:30:00 10.1 1.7 13 7.2 9.9 1.7 13.3 7.2 0.4 0 0.4 0.4 37 6 40 305 7 0 7 0 -17 0 -16.9 -17.3 01/21/2005 10:40:00 9.5 1.1 11.8 6.8 9.4 1.1 12.2 7.2 0.4 0 0.4 0.4 32 6 29 305 7 0 7 0 -17.1 0 -16.9 -17.3 01/21/2005 10:50:00 9.1 1 11.8 7.2 8.9 1.2 12.2 6.8 0.4 0 0.4 0.4 31 5 39 305 7 0 7 0 -17.1 0 -16.9 -17.3 01/21/2005 11:00:00 9.2 1 12.6 7.2 9.2 1.1 12.2 7.2 0.4 0 0.4 0.4 33 5 33 305 7 0 7 0 -17.1 0 -16.9 -17.3 01/21/2005 11:10:00 9.1 0.9 11.8 6.8 9 1 11.5 6.8 0.4 0 0.4 0.4 29 4 27 305 7 0 7 0 -17.2 0.1 -16.9 -17.5 01/21/2005 11:20:00 9.8 1.2 13 7.6 9.7 1.3 13 7.2 0.4 0 0.4 0.4 28 5 30 305 7 0 7 0 -17.3 0.1 -16.9 -17.5 01/21/2005 11:30:00 11.8 1 14.1 9.1 11.7 0.9 14.1 8.8 0.4 0 0.4 0.4 33 4 33 305 7 0 7 0 -17.3 0.1 -16.9 -17.5 01/21/2005 11:40:00 12 1 14.1 8.4 12 1.1 14.1 8.8 0.4 0 0.4 0.4 37 5 31 305 7 0 7 0 -17.3 0.1 -16.9 -17.5 01/21/2005 11:50:00 11.3 1.1 13.3 8.8 11.2 1.2 13.3 8.4 0.4 0 0.4 0.4 36 5 42 305 7 0 7 0 -17.3 0 -17.1 -17.5 01/21/2005 12:00:00 11.5 1.2 13.7 8.4 11.4 1.3 14.1 8.4 0.4 0 0.4 0.4 36 5 38 305 7 0 7 0 -17.4 0 -17.1 -17.5 01/21/2005 12:10:00 11.8 1.2 14.1 8.4 11.8 1.3 14.1 8 0.4 0 0.4 0.4 35 5 40 305 7 0 7 0 -17.5 0 -17.3 -17.5 01/21/2005 12:20:00 10.4 1.1 12.6 8.8 10.4 1.1 13 8.4 0.4 0 0.4 0.4 33 5 27 305 7 0 7 0 -17.5 0 -17.3 -17.5 01/21/2005 12:30:00 12.8 1.1 14.9 8.8 12.7 1.3 14.9 8.4 0.4 0 0.4 0.4 36 4 35 305 7 0 7 0 -17.5 0 -17.3 -17.7 01/21/2005 12:40:00 13 1.2 15.6 9.1 13 1.3 16.1 10.3 0.4 0 0.4 0.4 39 4 38 305 7 0 7 0 -17.5 0 -17.5 -17.7 01/21/2005 12:50:00 12.2 1.2 14.1 8.8 12.1 1.3 14.5 8.4 0.4 0 0.4 0.4 35 5 33 305 7 0 7 0 -17.5 0 -17.5 -17.7 01/21/2005 13:00:00 12.8 0.9 14.5 9.5 12.8 1 14.5 8.8 0.4 0 0.4 0.4 37 4 38 305 7 0 7 0 -17.5 0 -17.5 -17.7 01/21/2005 13:10:00 12.5 0.7 14.1 10.7 12.5 0.8 14.5 9.1 0.4 0 0.4 0.4 37 4 39 305 7 0 7 0 -17.5 0 -17.5 -17.7 01/21/2005 13:20:00 12.3 0.9 14.1 9.1 12.1 1 14.5 9.5 0.4 0 0.4 0.4 37 4 36 305 7 0 7 0 -17.5 0 -17.5 -17.7 01/21/2005 13:30:00 12.6 1 14.5 8.8 12.4 1.1 14.1 8.4 0.4 0 0.4 0.4 39 5 33 305 7 0 7 0 -17.5 0 -17.5 -17.7 01/21/2005 13:40:00 11.7 1.4 13.7 8.8 11.6 1.4 14.1 8.4 0.4 0 0.4 0.4 38 5 41 305 7 0 7 0 -17.5 0 -17.3 -17.5 01/21/2005 13:50:00 11.8 1.5 14.5 8 11.7 1.5 14.5 8 0.4 0 0.4 0.4 38 5 35 305 7 0 7 0 -17.5 0 -17.3 -17.7 01/21/2005 14:00:00 12 1 14.1 8.8 11.8 1.1 14.1 8.4 0.4 0 0.4 0.4 35 4 34 305 7 0 7 0 -17.6 0 -17.3 -17.7 01/21/2005 14:10:00 11.7 1.2 13.7 8.8 11.6 1.3 13.7 8.4 0.4 0 0.4 0.4 34 4 29 305 7 0 7 0 -17.5 0 -17.3 -17.7 01/21/2005 14:20:00 11.7 0.8 13.3 8.8 11.5 1 13.3 8.4 0.4 0 0.4 0.4 36 4 43 305 7 0 7 0 -17.5 0 -17.3 -17.7 01/21/2005 14:30:00 11 1 12.6 8.4 10.9 1.1 13 8.4 0.4 0 0.4 0.4 33 4 32 305 7 0 7 0 -17.6 0 -17.3 -17.9 01/21/2005 14:40:00 11.2 0.9 12.6 8.4 11 1 12.6 8.4 0.4 0 0.4 0.4 31 3 30 305 7 0 7 0 -17.7 0 -17.5 -17.9 01/21/2005 14:50:00 10.4 1.2 12.6 8.4 10.3 1.3 13 8 0.4 0 0.4 0.4 34 4 36 305 7 0 7 0 -17.7 0 -17.5 -17.9 01/21/2005 15:00:00 11.3 1.2 13.3 8.8 11.2 1.3 13.7 8.4 0.4 0 0.4 0.4 32 4 32 305 7 0 7 0 -17.8 0 -17.5 -18.1 01/21/2005 15:10:00 11.1 1.3 13.3 8.4 10.9 1.3 13.3 8 0.4 0 0.4 0.4 30 4 33 305 7 0 7 0 -17.8 0 -17.5 -18.1 01/21/2005 15:20:00 11.9 1.1 14.1 8.8 11.9 1.1 14.5 8.4 0.4 0 0.4 0.4 32 5 36 305 7 0 7 0 -17.9 0 -17.7 -18.1 01/21/2005 15:30:00 12.4 1.1 14.5 8.8 12.5 1.1 14.9 8.8 0.4 0 0.4 0.4 37 3 38 305 7 0 7 0 -17.9 0 -17.7 -18.1 01/21/2005 15:40:00 12.5 0.7 14.1 10.3 12.5 0.8 14.5 10.7 0.4 0 0.4 0.4 33 3 36 305 7 0 7 0 -17.9 0 -17.7 -18.1 01/21/2005 15:50:00 12.9 1 14.5 9.1 12.8 1.1 14.9 9.9 0.4 0 0.4 0.4 34 3 34 305 7 0 7 0 -18 0 -17.7 -18.1 01/21/2005 16:00:00 12.4 1 14.1 8.8 12.3 1.2 14.9 8.8 0.4 0 0.4 0.4 35 4 33 305 7 0 7 0 -18 0 -17.7 -18.1 01/21/2005 16:10:00 12.4 1 14.1 8.8 12.3 1.2 14.5 8.8 0.4 0 0.4 0.4 35 3 36 305 7 0 7 0 -18 0 -17.7 -18.1 01/21/2005 16:20:00 11.8 1 14.1 8.8 11.7 1 13.7 8.8 0.4 0 0.4 0.4 36 5 37 305 7 0 7 0 -18 0 -17.9 -18.1 01/21/2005 16:30:00 12.3 1.3 14.9 8.8 12.3 1.3 15.3 8.8 0.4 0 0.4 0.4 33 4 33 305 7 0 7 0 -18 0 -17.7 -18.1 01/21/2005 16:40:00 12.6 1.3 14.9 8.8 12.7 1.3 14.9 8.4 0.4 0 0.4 0.4 34 5 33 305 7 0 7 0 -18 0 -17.9 -18.1 01/21/2005 16:50:00 13.2 0.8 14.9 10.7 13.1 0.9 14.9 10.7 0.4 0 0.4 0.4 34 4 30 305 6 0 7 0 -18.1 0 -18.1 -18.1 01/21/2005 17:00:00 12.9 1 14.9 9.5 12.8 1.1 14.9 9.1 0.4 0 0.4 0.4 35 4 36 305 6 0 6 0 -18.1 0 -18.1 -18.2 01/21/2005 17:10:00 12.4 1.3 14.5 8.8 12.2 1.5 14.9 8.4 0.4 0 0.4 0.4 31 5 27 305 6 0 6 0 -18.1 0 -17.9 -18.2 01/21/2005 17:20:00 12.3 1 14.5 8.8 12.1 1.1 14.5 8.8 0.4 0 0.4 0.4 31 6 27 305 6 0 6 0 -18.1 0 -18.1 -18.2 01/21/2005 17:30:00 12.6 0.9 14.9 9.1 12.5 1.1 14.9 8.8 0.4 0 0.4 0.4 31 5 29 305 6 0 6 0 -18.2 0 -18.1 -18.4 01/21/2005 17:40:00 12.2 1 14.5 9.1 12.1 1 14.5 8.8 0.4 0 0.4 0.4 33 5 30 305 6 0 6 0 -18.2 0 -18.1 -18.4 01/21/2005 17:50:00 12.6 0.8 14.1 9.5 12.4 0.9 14.1 9.5 0.4 0 0.4 0.4 31 5 23 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/21/2005 18:00:00 12.9 1 15.3 9.5 12.7 1.1 14.9 9.5 0.4 0 0.4 0.4 31 5 33 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/21/2005 18:10:00 12.6 0.9 14.5 9.1 12.5 1 15.3 10.3 0.4 0 0.4 0.4 32 5 34 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/21/2005 18:20:00 13.6 0.7 14.9 11.5 13.4 1 15.6 10.3 0.4 0 0.4 0.4 33 4 36 305 6 0 6 0 -18.4 0 -18.2 -18.4 01/21/2005 18:30:00 13.5 0.8 15.3 11.5 13.3 0.9 15.3 11.1 0.4 0 0.4 0.4 33 3 35 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/21/2005 18:40:00 12.5 0.9 14.5 9.1 12.4 1 14.5 9.9 0.4 0 0.4 0.4 34 5 31 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/21/2005 18:50:00 13.3 0.8 15.3 10.3 13 1 15.3 9.9 0.4 0 0.4 0.4 31 4 32 305 6 0 6 0 -18.3 0 -17.9 -18.4 01/21/2005 19:00:00 12.2 1 15.3 9.1 12.1 1.1 14.9 8.4 0.4 0 0.4 0.4 35 4 46 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/21/2005 19:10:00 12.8 1 14.9 9.1 12.6 1.1 15.3 9.1 0.4 0 0.4 0.4 32 5 35 305 6 0 6 0 -18.4 0.1 -18.1 -18.4 01/21/2005 19:20:00 13.6 1 15.3 9.9 13.4 1.2 15.3 9.9 0.4 0 0.4 0.4 34 4 33 305 6 0 6 0 -18.4 0.1 -18.1 -18.4 01/21/2005 19:30:00 13.5 0.8 15.3 10.7 13.5 1 15.3 11.1 0.4 0 0.4 0.4 34 4 33 305 6 0 6 0 -18.4 0 -18.1 -18.4 01/21/2005 19:40:00 14.1 0.8 16.1 11.5 14 1 16.1 11.5 0.4 0 0.4 0.4 35 4 44 305 6 0 6 0 -18.4 0 -18.1 -18.4 01/21/2005 19:50:00 13.1 0.9 15.3 8.8 13 1 14.9 8.8 0.4 0 0.4 0.4 36 4 39 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/21/2005 20:00:00 12 1.2 14.5 8.8 11.9 1.3 14.9 8.8 0.4 0 0.4 0.4 38 5 40 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/21/2005 20:10:00 13.7 1 16.1 11.1 13.6 1.1 16.4 10.3 0.4 0 0.4 0.4 38 4 40 305 6 0 6 0 -18.4 0 -18.1 -18.4 01/21/2005 20:20:00 13 1 15.6 9.5 12.9 1.1 15.3 9.1 0.4 0 0.4 0.4 36 5 39 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/21/2005 20:30:00 12.8 1.1 14.9 9.1 12.7 1.1 15.3 8.8 0.4 0 0.4 0.4 35 5 33 305 6 0 6 0 -18.2 0 -18.1 -18.4 01/21/2005 20:40:00 12.5 1.3 14.9 8.8 12.4 1.3 15.3 8.4 0.4 0 0.4 0.4 31 4 33 305 6 0 6 0 -18.1 0 -18.1 -18.4 01/21/2005 20:50:00 13.2 0.9 14.5 9.9 12.9 1 15.3 9.9 0.4 0 0.4 0.4 31 3 29 305 6 0 6 0 -18.2 0 -18.1 -18.4 01/21/2005 21:00:00 11 1.1 13.7 8.4 10.9 1.2 14.1 7.6 0.4 0 0.4 0.4 25 7 31 305 6 0 6 0 -18.2 0.1 -18.1 -18.4 01/21/2005 21:10:00 10.5 1.2 13 7.6 10.4 1.3 12.6 7.6 0.4 0 0.4 0.4 24 4 21 305 6 0 6 0 -18.4 0 -18.2 -18.4 01/21/2005 21:20:00 9.2 0.8 12.2 7.6 9.3 1 11.8 7.6 0.4 0 0.4 0.4 22 5 29 305 6 0 6 0 -18.4 0 -18.2 -18.4 01/21/2005 21:30:00 9.6 1 12.2 7.6 9.7 1.1 11.8 8 0.4 0 0.4 0.4 22 5 17 305 6 0 6 0 -18.5 0 -18.2 -18.4 01/21/2005 21:40:00 10.8 1.1 12.6 8 10.8 1.2 13.3 8.4 0.4 0 0.4 0.4 20 5 29 305 6 0 6 0 -18.5 0 -18.4 -18.4 01/21/2005 21:50:00 10.2 1.1 12.6 8.4 10.2 1.2 12.6 8 0.4 0 0.4 0.4 18 4 16 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/21/2005 22:00:00 11.1 1 13 8.8 11.1 1.1 13 8.4 0.4 0 0.4 0.4 21 4 21 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/21/2005 22:10:00 11.2 1 13.7 8.8 10.9 1.1 13.3 8.4 0.4 0 0.4 0.4 25 5 30 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/21/2005 22:20:00 11.9 0.9 14.1 8.8 11.8 1 14.1 8.4 0.4 0 0.4 0.4 26 4 29 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/21/2005 22:30:00 11.8 1 14.1 8.8 11.6 1.1 14.1 8.4 0.4 0 0.4 0.4 32 5 33 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/21/2005 22:40:00 11.6 1.2 13.7 8.8 11.5 1.3 13.7 8.4 0.4 0 0.4 0.4 28 5 30 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/21/2005 22:50:00 11.6 1.3 14.1 8 11.6 1.3 14.1 8 0.4 0 0.4 0.4 29 4 28 305 6 0 6 0 -18.7 0 -18.4 -18.8 01/21/2005 23:00:00 10.3 1.1 12.6 8 10.2 1.2 12.6 7.6 0.4 0 0.4 0.4 27 6 32 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/21/2005 23:10:00 11.1 1.2 13.3 8 11 1.3 13 8 0.4 0 0.4 0.4 27 5 28 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/21/2005 23:20:00 10.8 1.1 13 8.8 10.7 1.1 13 8.4 0.4 0 0.4 0.4 27 5 28 305 6 0 6 0 -18.7 0 -18.4 -18.8 01/21/2005 23:30:00 10.7 1.1 12.6 8 10.7 1.2 13 8 0.4 0 0.4 0.4 27 5 29 305 6 0 6 0 -18.7 0 -18.4 -18.8 01/21/2005 23:40:00 9.4 1.2 11.8 7.2 9.5 1.2 12.2 6.8 0.4 0 0.4 0.4 28 6 30 305 6 0 6 0 -18.7 0 -18.4 -19 01/21/2005 23:50:00 9 0.7 11.8 6.8 9 0.8 11.8 6.8 0.4 0 0.4 0.4 32 6 35 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/22/2005 00:00:00 9.4 1 12.6 7.2 9.4 1.2 12.2 6.8 0.4 0 0.4 0.4 30 6 35 305 6 0 6 0 -18.5 0 -18.1 -18.6 01/22/2005 00:10:00 8.8 0.5 11.1 7.2 8.7 0.6 11.1 7.2 0.4 0 0.4 0.4 27 7 32 305 6 0 6 0 -18.5 0 -18.2 -18.4 01/22/2005 00:20:00 9.3 0.9 12.2 6.8 9.2 1 11.8 7.2 0.4 0 0.4 0.4 26 7 18 305 6 0 6 0 -18.4 0 -18.2 -18.4 01/22/2005 00:30:00 9.4 1 11.5 6.8 9.4 1.2 12.2 6.5 0.4 0 0.4 0.4 28 5 18 305 6 0 6 0 -18.5 0 -18.2 -18.4 01/22/2005 00:40:00 9.1 0.8 11.8 7.2 9 0.9 11.5 7.2 0.4 0 0.4 0.4 25 6 18 305 6 0 6 0 -18.5 0 -18.4 -18.6 01/22/2005 00:50:00 9.5 0.9 11.8 7.2 9.5 1 12.2 7.6 0.4 0 0.4 0.4 28 5 30 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/22/2005 01:00:00 9.3 1 12.2 6.8 9.3 1.1 12.2 6.8 0.4 0 0.4 0.4 23 7 29 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/22/2005 01:10:00 9.9 1 13 8 10 1.1 12.6 7.2 0.4 0 0.4 0.4 22 5 21 305 6 0 6 0 -18.7 0 -18.4 -18.8 01/22/2005 01:20:00 9.9 1.1 12.2 7.6 9.9 1.2 13 7.2 0.4 0 0.4 0.4 25 6 27 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/22/2005 01:30:00 10.1 1.1 13 7.6 10.1 1.1 12.6 8 0.4 0 0.4 0.4 20 6 24 305 6 0 6 0 -18.6 0 -18.4 -18.6 01/22/2005 01:40:00 10.3 1.1 13 7.6 10.4 1.2 13.3 8 0.4 0 0.4 0.4 21 6 23 305 6 0 6 0 -18.6 0 -18.4 -18.8 01/22/2005 01:50:00 10.5 1 13 8 10.6 1.1 13 8.4 0.4 0 0.4 0.4 20 5 23 305 6 0 6 0 -18.7 0 -18.4 -19 01/22/2005 02:00:00 10.4 1.1 13 8 10.5 1.1 13 7.2 0.4 0 0.4 0.4 21 6 26 305 6 0 6 0 -18.7 0 -18.4 -18.8 01/22/2005 02:10:00 11.3 1 13.3 8 11.4 1 13.7 7.6 0.4 0 0.4 0.4 18 5 15 305 6 0 5 0 -18.7 0 -18.4 -19 01/22/2005 02:20:00 10.6 1.1 13 8.4 10.6 1.3 13 7.6 0.4 0 0.4 0.4 19 6 16 305 5 0 5 0 -18.9 0.1 -18.4 -19 01/22/2005 02:30:00 10.9 1 13 8.8 10.9 1.1 13.7 8.4 0.4 0 0.4 0.4 16 6 15 305 5 0 5 0 -19 0 -18.8 -19 01/22/2005 02:40:00 11 1.2 13.3 8.4 11.2 1.2 13.3 8.4 0.4 0 0.4 0.4 15 5 18 305 5 0 5 0 -19 0 -18.8 -19 01/22/2005 02:50:00 10.9 1 13 8.8 11 1.1 13.3 8.4 0.4 0 0.4 0.4 20 5 19 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 03:00:00 10.8 1.2 13 8 10.8 1.3 13.3 8.4 0.4 0 0.4 0.4 19 4 11 305 5 0 5 0 -19 0 -18.8 -19 01/22/2005 03:10:00 10.6 1.3 13.3 8 10.6 1.3 13.3 8 0.4 0 0.4 0.4 15 6 8 305 5 0 5 0 -18.9 0.1 -18.6 -19 01/22/2005 03:20:00 11.5 0.8 13.7 8.8 11.6 1 13.7 8.8 0.4 0 0.4 0.4 15 5 14 305 5 0 5 0 -19.1 0 -19 -19.3 01/22/2005 03:30:00 11.6 1 13.3 8.4 11.6 1 13.7 8.4 0.4 0 0.4 0.4 15 4 11 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 03:40:00 11.4 0.8 13.3 8.8 11.5 0.8 13.3 8.8 0.4 0 0.4 0.4 14 4 16 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 03:50:00 11.4 0.8 12.6 8.8 11.5 0.9 13 8.4 0.4 0 0.4 0.4 13 3 16 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 04:00:00 10.6 1.1 13 8 10.8 1.2 13.3 8 0.4 0 0.4 0.4 10 4 9 305 5 0 5 0 -19 0 -18.8 -19.2 01/22/2005 04:10:00 11 1.1 13 8.8 11.1 1.2 13 8.4 0.4 0 0.4 0.4 13 4 24 305 5 0 5 0 -18.8 0 -18.4 -19 01/22/2005 04:20:00 10.8 1.1 13.3 8.4 10.9 1.3 13.7 8 0.4 0 0.4 0.4 12 6 15 305 5 0 5 0 -18.7 0 -18.4 -19 01/22/2005 04:30:00 11.1 1.2 13.3 8.4 11.2 1.4 13.3 8 0.4 0 0.4 0.4 12 4 13 305 5 0 5 0 -18.8 0.1 -18.4 -19 01/22/2005 04:40:00 11.2 1 13 8.8 11.2 1.2 13.3 8.4 0.4 0 0.4 0.4 11 4 13 305 5 0 5 0 -18.9 0.1 -18.6 -19.2 01/22/2005 04:50:00 11.6 1.2 13.3 8.8 11.7 1.2 13.7 8.8 0.4 0 0.4 0.4 10 4 5 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 05:00:00 11.6 1 13.7 8.8 11.8 1 13.7 8.8 0.4 0 0.4 0.4 11 3 10 305 5 0 5 0 -19 0 -18.8 -19.2 01/22/2005 05:10:00 11.9 0.8 13.3 9.1 11.9 1 13.7 8.8 0.4 0 0.4 0.4 11 3 15 305 5 0 5 0 -19 0 -18.8 -19.2 01/22/2005 05:20:00 11.8 1 13.3 8.8 11.9 1.1 14.1 8.4 0.4 0 0.4 0.4 11 3 11 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 05:30:00 11.7 0.8 13.3 8.8 11.8 1 13.3 8.8 0.4 0 0.4 0.4 12 3 14 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 05:40:00 11.3 1 13.3 8.8 11.3 1 13.3 8.4 0.4 0 0.4 0.4 11 4 7 305 5 0 5 0 -19 0 -18.8 -19.2 01/22/2005 05:50:00 11.1 0.9 12.6 8.8 11.2 0.9 13.3 8.4 0.4 0 0.4 0.4 11 3 11 305 5 0 5 0 -19.1 0 -18.8 -19.2 01/22/2005 06:00:00 11.2 0.9 12.6 8.8 11.4 0.8 13 8.8 0.4 0 0.4 0.4 10 4 14 305 5 0 5 0 -19.1 0 -18.8 -19 01/22/2005 06:10:00 11.4 0.9 13 8.8 11.3 1 13.7 8.8 0.4 0 0.4 0.4 12 4 12 305 5 0 5 0 -19 0 -18.8 -19 01/22/2005 06:20:00 10.8 1.2 13 8 10.9 1.3 13.3 7.6 0.4 0 0.4 0.4 11 4 11 305 5 0 5 0 -19.1 0 -18.8 -19.2 01/22/2005 06:30:00 11 1 12.6 7.6 11.1 1 12.6 8 0.4 0 0.4 0.4 10 4 13 305 5 0 5 0 -19.1 0 -18.8 -19.2 01/22/2005 06:40:00 10.4 1 12.2 8.4 10.5 1 12.6 8.4 0.4 0 0.4 0.4 8 4 8 305 5 0 5 0 -19 0 -18.8 -19.2 01/22/2005 06:50:00 9.9 1 11.5 7.6 10.2 1.1 12.2 7.6 0.4 0 0.4 0.4 7 4 8 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 07:00:00 9.8 0.9 11.8 8.4 10.2 1 11.8 8.4 0.4 0 0.4 0.4 7 3 6 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 07:10:00 9.8 1 12.2 8.4 10 1 12.2 8.4 0.4 0 0.4 0.4 6 3 7 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 07:20:00 9.6 1 11.8 7.6 9.6 1.2 11.8 7.6 0.4 0 0.4 0.4 8 4 7 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 07:30:00 8.9 0.6 11.5 7.2 8.9 0.8 11.5 7.2 0.4 0 0.4 0.4 11 5 7 305 5 0 5 0 -18.9 0.1 -18.4 -19 01/22/2005 07:40:00 8.6 0.5 9.5 6.8 8.5 0.5 10.3 6.5 0.4 0 0.4 0.4 9 3 9 305 5 0 5 0 -19 0 -18.6 -19 01/22/2005 07:50:00 8.8 0.6 10.7 6.8 8.7 0.6 11.5 6.8 0.4 0 0.4 0.4 6 4 5 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 08:00:00 8.6 0.5 9.1 7.2 8.5 0.5 10.7 6.8 0.4 0 0.4 0.4 8 4 359 305 5 0 5 0 -19 0 -18.8 -19 01/22/2005 08:10:00 8.8 0.5 9.5 6.8 8.7 0.8 10.7 7.2 0.4 0 0.4 0.4 9 4 5 305 5 0 5 0 -19 0 -18.6 -19.2 01/22/2005 08:20:00 8.8 0.5 10.7 7.6 8.7 0.7 11.1 7.2 0.4 0 0.4 0.4 8 4 9 305 5 0 5 0 -19 0 -18.8 -19 01/22/2005 08:30:00 9.1 0.6 11.5 7.6 9.3 0.9 11.5 7.6 0.4 0 0.4 0.4 11 4 12 305 5 0 5 0 -18.9 0 -18.6 -19 01/22/2005 08:40:00 8.7 0.6 10.7 6.8 8.7 0.8 11.1 6.1 0.4 0 0.4 0.4 11 5 14 305 5 0 5 0 -18.7 0 -18.4 -19 01/22/2005 08:50:00 8.6 0.5 9.5 6.8 8.6 0.5 10.7 6.8 0.4 0 0.4 0.4 9 3 12 305 5 0 5 0 -18.9 0 -18.6 -19 01/22/2005 09:00:00 9.5 0.8 11.5 8 9.6 1 11.8 7.6 0.4 0 0.4 0.4 10 3 5 305 5 0 5 0 -18.9 0 -18.6 -19 01/22/2005 09:10:00 10.4 0.8 11.8 8.4 10.6 0.9 12.2 8.4 0.4 0 0.4 0.4 10 3 8 305 5 0 5 0 -19 0 -18.8 -19 01/22/2005 09:20:00 11 1 12.6 8.4 11.1 1.1 13.3 8.4 0.4 0 0.4 0.4 11 3 15 305 5 0 5 0 -18.9 0 -18.6 -19 01/22/2005 09:30:00 10.8 1 12.6 8.8 10.8 1 13 8.4 0.4 0 0.4 0.4 12 3 12 305 5 0 5 0 -19 0 -18.8 -19 01/22/2005 09:40:00 10.3 1 12.2 8.4 10.3 1.1 12.2 8 0.4 0 0.4 0.4 9 3 6 305 5 0 5 0 -19.1 0 -18.8 -19.2 01/22/2005 09:50:00 9.8 1 11.8 7.6 9.9 1.1 11.8 7.2 0.4 0 0.4 0.4 8 5 9 305 5 0 5 0 -19.1 0 -18.8 -19.2 01/22/2005 10:00:00 9.6 1 12.2 8 9.8 1.1 12.2 7.6 0.4 0 0.4 0.4 10 4 11 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 10:10:00 9.5 0.9 11.8 7.6 9.6 1 11.8 7.2 0.4 0 0.4 0.4 10 4 5 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 10:20:00 9.4 0.7 11.8 8.4 9.9 1 11.8 8.4 0.4 0 0.4 0.4 12 4 12 305 5 0 5 0 -19 0 -18.8 -19 01/22/2005 10:30:00 10.4 0.9 12.2 8.4 10.5 0.9 12.2 8.4 0.4 0 0.4 0.4 12 3 9 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 10:40:00 9.9 1.1 12.2 7.6 9.9 1.2 12.2 7.6 0.4 0 0.4 0.4 13 4 14 305 5 0 5 0 -19 0 -18.8 -19.2 01/22/2005 10:50:00 11.3 0.9 13 8.8 11.3 1 13.3 8.4 0.4 0 0.4 0.4 14 4 11 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 11:00:00 11.4 0.8 13 8.8 11.5 0.9 13.3 8.8 0.4 0 0.4 0.4 15 4 14 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 11:10:00 11.1 0.9 12.6 8.8 11.1 1 12.6 8.4 0.4 0 0.4 0.4 15 3 17 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 11:20:00 11 1 13 8.4 11 1.1 13 8 0.4 0 0.4 0.4 13 3 13 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 11:30:00 9.7 1 11.5 7.6 9.8 1 11.8 7.6 0.4 0 0.4 0.4 13 4 11 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 11:40:00 10 0.9 12.6 8.4 10.1 1 11.8 8 0.4 0 0.4 0.4 13 3 11 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 11:50:00 9.8 1 11.8 7.2 9.9 1 11.8 7.6 0.4 0 0.4 0.4 10 3 9 305 5 0 5 0 -19.1 0 -19 -19.2 01/22/2005 12:00:00 10.3 1 12.2 8 10.4 1.1 12.6 8 0.4 0 0.4 0.4 15 4 12 305 5 0 5 0 -19 0 -18.8 -19.2 01/22/2005 12:10:00 11.4 1 13.3 8.8 11.5 1.1 13.7 8.4 0.4 0 0.4 0.4 16 4 13 305 5 0 5 0 -18.9 0 -18.4 -19 01/22/2005 12:20:00 12.2 1 14.1 8.8 12.1 1.1 14.1 8.4 0.4 0 0.4 0.4 21 6 32 305 5 0 5 0 -18.8 0 -18.6 -19 01/22/2005 12:30:00 12.1 1 14.1 9.1 12 1.1 14.5 8.8 0.4 0 0.4 0.4 21 5 20 305 5 0 5 0 -18.6 0 -18.2 -18.8 01/22/2005 12:40:00 12.2 1 14.1 8.8 12.1 1.1 14.1 8.8 0.4 0 0.4 0.4 23 5 25 305 6 0 6 0 -18.4 0 -18.1 -18.4 01/22/2005 12:50:00 11.7 0.9 13.3 8.8 11.6 1 13.3 8.4 0.4 0 0.4 0.4 26 4 29 305 6 0 6 0 -18.4 0.1 -18.1 -18.4 01/22/2005 13:00:00 12.1 1 14.1 8.8 12 1.2 14.1 8.4 0.4 0 0.4 0.4 25 4 26 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/22/2005 13:10:00 10.2 1.3 13.3 7.6 10.1 1.3 13 7.6 0.4 0 0.4 0.4 31 5 26 305 6 0 6 0 -18.1 0 -17.9 -18.4 01/22/2005 13:20:00 10.1 1.1 12.6 8.4 10 1.2 13 8 0.4 0 0.4 0.4 30 6 33 305 6 0 6 0 -18.1 0 -17.7 -18.2 01/22/2005 13:30:00 10.4 1.2 12.2 7.6 10.4 1.3 12.6 7.6 0.4 0 0.4 0.4 31 4 30 305 6 0 6 0 -18.1 0.1 -17.9 -18.4 01/22/2005 13:40:00 10.8 0.9 12.6 8.8 10.6 1 12.2 8.4 0.4 0 0.4 0.4 35 3 30 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/22/2005 13:50:00 10.9 1 12.6 8.4 10.9 1.1 13 8 0.4 0 0.4 0.4 32 3 33 305 6 0 6 0 -18.3 0.1 -18.1 -18.4 01/22/2005 14:00:00 11.6 0.9 13.3 8.4 11.5 0.9 13.3 8.4 0.4 0 0.4 0.4 31 3 29 305 6 0 6 0 -18.4 0.1 -18.1 -18.4 01/22/2005 14:10:00 9.1 0.6 12.2 7.6 9.2 0.9 12.6 7.6 0.4 0 0.4 0.4 32 4 37 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/22/2005 14:20:00 9.9 1 12.6 8.8 10 1.1 12.6 8.4 0.4 0 0.4 0.4 31 4 32 305 6 0 6 0 -18.2 0 -18.1 -18.4 01/22/2005 14:30:00 9.4 1 12.2 7.2 9.4 1.1 12.6 7.2 0.4 0 0.4 0.4 30 4 29 305 6 0 6 0 -18.1 0 -17.9 -18.4 01/22/2005 14:40:00 9.6 1 11.8 7.2 9.5 1.2 12.2 6.8 0.4 0 0.4 0.4 30 4 32 305 6 0 6 0 -18.1 0 -17.9 -18.2 01/22/2005 14:50:00 9.9 1 11.8 8.4 10 1.1 11.8 8 0.4 0 0.4 0.4 32 4 34 305 6 0 6 0 -18.1 0 -17.9 -18.4 01/22/2005 15:00:00 9.1 0.5 10.7 7.6 9.1 0.8 11.1 7.6 0.4 0 0.4 0.4 30 4 35 305 6 0 6 0 -18 0.1 -17.7 -18.2 01/22/2005 15:10:00 8.8 0.6 10.7 6.1 8.7 0.8 11.1 6.5 0.4 0 0.4 0.4 24 6 22 305 6 0 6 0 -17.8 0 -17.7 -18.1 01/22/2005 15:20:00 8.2 0.6 9.1 6.5 8.1 0.6 9.1 6.1 0.4 0 0.4 0.4 27 5 19 305 6 0 6 0 -17.9 0 -17.7 -18.1 01/22/2005 15:30:00 8.5 0.5 9.5 6.8 8.2 0.6 9.1 6.5 0.4 0 0.4 0.4 29 5 33 305 6 0 6 0 -17.9 0 -17.7 -18.1 01/22/2005 15:40:00 8.4 0.6 9.1 6.5 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 29 3 30 305 6 0 6 0 -17.9 0 -17.7 -18.1 01/22/2005 15:50:00 8 0.6 9.1 6.5 8 0.5 9.1 6.5 0.4 0 0.4 0.4 26 4 31 305 6 0 6 0 -17.9 0 -17.5 -18.1 01/22/2005 16:00:00 7.5 0.7 8.8 5.7 7.4 0.7 8.8 5.7 0.4 0 0.4 0.4 28 4 25 305 6 0 6 0 -17.7 0 -17.5 -17.9 01/22/2005 16:10:00 7.6 0.8 9.1 5.3 7.4 0.8 8.8 5.3 0.4 0 0.4 0.4 26 5 29 305 6 0 6 0 -17.6 0 -17.5 -17.9 01/22/2005 16:20:00 7.7 0.6 9.1 5.7 7.7 0.6 8.8 5.7 0.4 0 0.4 0.4 21 5 13 305 6 0 6 0 -17.6 0 -17.5 -17.9 01/22/2005 16:30:00 7.9 0.7 9.1 6.1 7.7 0.7 8.8 5.7 0.4 0 0.4 0.4 15 8 13 305 6 0 7 0 -17.6 0 -17.5 -17.9 01/22/2005 16:40:00 8 0.8 9.1 6.1 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 10 5 2 305 6 0 6 0 -17.7 0 -17.5 -18.1 01/22/2005 16:50:00 8.8 0.4 9.5 6.8 8.6 0.5 10.7 6.8 0.4 0 0.4 0.4 16 3 14 305 6 0 6 0 -17.9 0 -17.7 -18.1 01/22/2005 17:00:00 8.8 0.4 9.5 7.2 8.9 0.7 10.7 7.2 0.4 0 0.4 0.4 13 3 9 305 6 0 6 0 -18.1 0 -17.9 -18.2 01/22/2005 17:10:00 9.1 0.7 11.1 7.6 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 11 4 15 305 6 0 6 0 -18.2 0 -18.1 -18.4 01/22/2005 17:20:00 9.1 0.5 11.1 7.2 9.2 0.8 11.5 7.6 0.4 0 0.4 0.4 10 3 9 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/22/2005 17:30:00 8.6 0.5 9.5 6.8 8.5 0.7 10.7 6.1 0.4 0 0.4 0.4 12 4 12 305 6 0 6 0 -18.3 0 -18.1 -18.4 01/22/2005 17:40:00 8.7 0.5 10.3 7.2 8.6 0.6 11.1 6.8 0.4 0 0.4 0.4 13 4 13 305 5 0 5 0 -18.4 0 -18.1 -18.4 01/22/2005 17:50:00 8.5 0.6 9.5 6.1 8.4 0.7 10.7 6.5 0.4 0 0.4 0.4 16 4 12 305 5 0 5 0 -18.5 0 -18.2 -18.4 01/22/2005 18:00:00 8.9 0.4 10.7 7.2 8.7 0.6 10.7 6.8 0.4 0 0.4 0.4 15 3 11 305 5 0 5 0 -18.5 0 -18.4 -18.6 01/22/2005 18:10:00 8.9 0.4 10.7 7.6 8.9 0.6 10.7 7.6 0.4 0 0.4 0.4 16 5 18 305 5 0 5 0 -18.6 0 -18.4 -18.6 01/22/2005 18:20:00 9.3 1 11.8 7.2 9.2 1.1 12.2 6.8 0.4 0 0.4 0.4 16 4 17 305 5 0 5 0 -18.6 0 -18.4 -18.8 01/22/2005 18:30:00 8.7 0.4 10.7 7.2 8.5 0.5 11.1 7.2 0.4 0 0.4 0.4 19 4 19 305 5 0 5 0 -18.8 0 -18.4 -19 01/22/2005 18:40:00 8.9 0.5 11.1 7.6 8.7 0.5 10.7 7.2 0.4 0 0.4 0.4 19 4 18 305 5 0 5 0 -18.8 0 -18.6 -19 01/22/2005 18:50:00 8.3 1.1 11.5 6.1 8.3 1.1 11.8 6.1 0.4 0 0.4 0.4 16 4 19 305 5 0 5 0 -18.8 0 -18.4 -19 01/22/2005 19:00:00 7.7 0.6 8.8 6.1 7.6 0.6 8.8 6.1 0.4 0 0.4 0.4 14 5 13 305 5 0 5 0 -18.7 0 -18.4 -18.8 01/22/2005 19:10:00 8.2 0.6 9.1 6.5 8.1 0.6 9.1 6.5 0.4 0 0.4 0.4 16 4 14 305 5 0 5 0 -18.5 0 -18.2 -18.6 01/22/2005 19:20:00 8.9 0.7 11.8 7.6 8.8 0.9 11.8 6.8 0.4 0 0.4 0.4 19 5 23 305 5 0 5 0 -18.3 0 -18.1 -18.4 01/22/2005 19:30:00 10.4 1.1 12.6 8.4 10.3 1 12.2 8.4 0.4 0 0.4 0.4 21 3 17 305 5 0 5 0 -18.1 0 -18.1 -18.4 01/22/2005 19:40:00 10.5 1.2 12.6 8 10.4 1.2 12.6 8 0.4 0 0.4 0.4 20 4 15 305 6 0 6 0 -18.1 0 -17.9 -18.1 01/22/2005 19:50:00 10.4 1 12.2 8.4 10.3 1.1 12.2 7.6 0.4 0 0.4 0.4 23 5 29 305 6 0 6 0 -18 0 -17.9 -18.1 01/22/2005 20:00:00 9.3 0.8 11.8 7.2 9.1 0.8 11.5 7.2 0.4 0 0.4 0.4 25 5 31 305 6 0 6 0 -18 0 -17.7 -18.1 01/22/2005 20:10:00 8.8 0.5 10.3 6.8 8.5 0.6 10.3 6.8 0.4 0 0.4 0.4 23 4 28 305 6 0 6 0 -18 0 -17.7 -18.1 01/22/2005 20:20:00 8.4 0.6 9.1 6.1 8.2 0.6 9.1 6.1 0.4 0 0.4 0.4 24 6 19 305 6 0 6 0 -17.9 0 -17.5 -18.1 01/22/2005 20:30:00 8.2 0.6 9.1 6.8 8 0.5 8.8 6.1 0.4 0 0.4 0.4 29 4 31 305 6 0 6 0 -17.9 0 -17.7 -18.1 01/22/2005 20:40:00 8.7 0.5 9.5 6.8 8.6 0.7 10.7 6.5 0.4 0 0.4 0.4 25 6 30 305 6 0 6 0 -17.9 0 -17.5 -18.1 01/22/2005 20:50:00 9.8 1 11.8 7.6 9.7 1.1 11.8 7.2 0.4 0 0.4 0.4 26 4 25 305 6 0 6 0 -18 0 -17.9 -18.1 01/22/2005 21:00:00 9.9 1 12.2 8 9.8 1.1 11.8 7.6 0.4 0 0.4 0.4 28 4 31 305 6 0 6 0 -18 0 -17.9 -18.1 01/22/2005 21:10:00 9.2 0.8 11.1 7.6 9.1 1 11.5 6.8 0.4 0 0.4 0.4 28 4 29 305 6 0 6 0 -18 0 -17.9 -18.1 01/22/2005 21:20:00 9.1 0.9 11.5 7.2 8.9 1 11.1 6.8 0.4 0 0.4 0.4 24 5 25 305 6 0 6 0 -17.9 0 -17.7 -18.1 01/22/2005 21:30:00 8.9 0.4 10.7 7.2 8.7 0.6 10.7 6.8 0.4 0 0.4 0.4 27 4 28 305 6 0 6 0 -17.9 0 -17.7 -18.1 01/22/2005 21:40:00 8.9 0.4 9.5 7.2 8.8 0.5 10.7 7.2 0.4 0 0.4 0.4 26 4 31 305 6 0 6 0 -18 0 -17.9 -18.1 01/22/2005 21:50:00 9.5 1 11.8 7.2 9.5 1.1 12.2 7.6 0.4 0 0.4 0.4 21 4 25 305 6 0 6 0 -17.9 0 -17.7 -18.1 01/22/2005 22:00:00 9.8 0.9 12.2 7.6 9.8 1 11.8 7.6 0.4 0 0.4 0.4 26 3 35 305 6 0 6 0 -17.9 0 -17.5 -18.1 01/22/2005 22:10:00 8.9 0.5 10.7 7.6 8.8 0.5 10.7 6.5 0.4 0 0.4 0.4 22 6 31 305 6 0 6 0 -17.9 0 -17.7 -18.1 01/22/2005 22:20:00 8.7 0.7 10.3 6.5 8.6 0.7 10.7 6.5 0.4 0 0.4 0.4 17 4 16 305 6 0 6 0 -18 0 -17.7 -18.1 01/22/2005 22:30:00 8.4 0.5 9.1 6.1 8.3 0.5 9.1 6.5 0.4 0 0.4 0.4 19 4 18 305 6 0 6 0 -17.9 0 -17.5 -18.1 01/22/2005 22:40:00 8.5 0.5 9.1 6.8 8.4 0.5 9.9 6.5 0.4 0 0.4 0.4 22 4 25 305 6 0 6 0 -18 0 -17.7 -18.1 01/22/2005 22:50:00 8.2 0.5 9.1 6.5 8.1 0.5 8.8 6.1 0.4 0 0.4 0.4 15 5 10 305 6 0 6 0 -18.1 0 -17.7 -18.2 01/22/2005 23:00:00 8.5 0.5 9.1 7.2 8.4 0.5 9.5 6.5 0.4 0 0.4 0.4 17 4 18 305 6 0 6 0 -18.1 0 -17.9 -18.2 01/22/2005 23:10:00 8.7 0.4 9.5 6.8 8.5 0.4 10.3 6.8 0.4 0 0.4 0.4 19 4 21 305 6 0 6 0 -18.2 0.1 -18.1 -18.4 01/22/2005 23:20:00 8.9 0.6 11.1 6.8 8.8 0.8 11.1 6.8 0.4 0 0.4 0.4 19 4 25 305 6 0 6 0 -18.2 0 -18.1 -18.4 01/22/2005 23:30:00 9.9 0.9 11.8 8 10.1 0.9 11.8 8.4 0.4 0 0.4 0.4 19 5 19 305 6 0 6 0 -18.2 0 -18.1 -18.4 01/22/2005 23:40:00 9.6 0.9 12.2 7.6 9.6 1 12.6 8 0.4 0 0.4 0.4 16 4 13 305 5 0 5 0 -18.3 0.1 -18.1 -18.4 01/22/2005 23:50:00 10.2 1.1 12.6 7.6 10.2 1.2 13 7.2 0.4 0 0.4 0.4 22 5 22 305 5 0 5 0 -18.5 0 -18.1 -18.4 01/23/2005 00:00:00 10.6 1.2 12.6 7.6 10.5 1.2 12.6 7.6 0.4 0 0.4 0.4 21 4 21 305 5 0 5 0 -18.6 0 -18.4 -18.8 01/23/2005 00:10:00 11.2 0.9 13 8.8 11.2 1 13 8.4 0.4 0 0.4 0.4 21 4 19 305 5 0 5 0 -18.7 0 -18.4 -18.8 01/23/2005 00:20:00 10.8 1.1 13 8.8 10.8 1.1 13 8.4 0.4 0 0.4 0.4 21 4 21 305 5 0 5 0 -18.7 0 -18.4 -19 01/23/2005 00:30:00 10.7 1 12.6 7.6 10.7 1 12.6 8 0.4 0 0.4 0.4 22 4 21 305 5 0 5 0 -18.7 0 -18.4 -18.8 01/23/2005 00:40:00 11.2 1.1 13 8 11.1 1.1 13.3 8.4 0.4 0 0.4 0.4 23 5 27 305 5 0 5 0 -18.6 0 -18.4 -18.6 01/23/2005 00:50:00 10.8 1.1 12.6 8.8 10.8 1.1 12.6 8.4 0.4 0 0.4 0.4 21 4 18 305 5 0 5 0 -18.5 0 -18.2 -18.6 01/23/2005 01:00:00 10.4 1.1 13 8 10.3 1.1 12.2 8 0.4 0 0.4 0.4 20 4 20 305 5 0 5 0 -18.5 0 -18.1 -18.6 01/23/2005 01:10:00 10.1 1 12.2 8.4 10 1.1 12.2 8 0.4 0 0.4 0.4 21 5 30 305 5 0 5 0 -18.4 0 -18.1 -18.4 01/23/2005 01:20:00 10.9 1 12.6 8.4 10.9 1 12.6 8 0.4 0 0.4 0.4 25 4 26 305 5 0 6 0 -18.5 0.1 -18.1 -18.6 01/23/2005 01:30:00 10.8 1 13 8.4 10.8 1.1 12.6 8 0.4 0 0.4 0.4 23 4 24 305 5 0 5 0 -18.6 0 -18.4 -18.8 01/23/2005 01:40:00 11 0.9 12.2 8.4 10.9 1 12.6 8.4 0.4 0 0.4 0.4 27 4 28 305 5 0 6 0 -18.5 0 -18.2 -18.6 01/23/2005 01:50:00 10.8 1 12.2 8.8 10.7 1 13 8.4 0.4 0 0.4 0.4 26 4 25 305 5 0 5 0 -18.5 0 -18.2 -18.4 01/23/2005 02:00:00 10.4 1 12.2 8.8 10.3 1 11.8 8 0.4 0 0.4 0.4 22 4 21 305 5 0 5 0 -18.5 0 -18.2 -18.4 01/23/2005 02:10:00 11.1 0.9 12.6 8.8 11 0.9 12.6 8.4 0.4 0 0.4 0.4 20 3 18 305 5 0 5 0 -18.6 0 -18.4 -18.6 01/23/2005 02:20:00 9.7 1 11.8 7.6 9.6 1.1 12.2 8 0.4 0 0.4 0.4 27 7 36 305 5 0 5 0 -18.5 0 -18.2 -18.8 01/23/2005 02:30:00 9.9 0.9 11.8 8 9.8 1 12.2 8 0.4 0 0.4 0.4 27 6 36 305 5 0 5 0 -18.6 0 -18.2 -18.6 01/23/2005 02:40:00 10.8 1 13 7.2 10.7 1.1 13 7.6 0.4 0 0.4 0.4 28 5 27 305 5 0 5 0 -18.5 0 -18.2 -18.8 01/23/2005 02:50:00 11 0.9 12.6 8.8 11 0.9 12.6 8.4 0.4 0 0.4 0.4 26 5 29 305 5 0 5 0 -18.6 0 -18.4 -18.8 01/23/2005 03:00:00 10.4 1 12.2 8 10.4 1 12.2 8 0.4 0 0.4 0.4 28 5 27 305 5 0 5 0 -18.6 0 -18.4 -18.8 01/23/2005 03:10:00 9.9 1 12.2 8.4 10 1 12.2 8 0.4 0 0.4 0.4 30 4 32 305 5 0 5 0 -18.7 0 -18.4 -18.8 01/23/2005 03:20:00 9 0.4 10.7 7.2 9.1 0.7 11.1 7.6 0.4 0 0.4 0.4 27 4 27 305 5 0 5 0 -18.7 0 -18.4 -18.8 01/23/2005 03:30:00 9.3 0.7 11.8 8 9.4 0.9 11.5 8 0.4 0 0.4 0.4 24 4 16 305 5 0 5 0 -18.7 0 -18.4 -18.8 01/23/2005 03:40:00 9.4 0.9 11.8 7.6 9.3 0.9 11.8 7.6 0.4 0 0.4 0.4 26 4 25 305 5 0 5 0 -18.6 0 -18.4 -18.8 01/23/2005 03:50:00 9.3 1 11.8 6.8 9.2 1 11.8 6.8 0.4 0 0.4 0.4 29 5 27 305 5 0 5 0 -18.7 0 -18.4 -18.8 01/23/2005 04:00:00 10.8 0.8 12.2 8.4 10.8 0.9 12.6 8.4 0.4 0 0.4 0.4 31 5 33 305 5 0 5 0 -18.8 0 -18.6 -19 01/23/2005 04:10:00 11.1 1.1 13.3 8.4 11.1 1.2 13.7 8 0.4 0 0.4 0.4 28 4 22 305 5 0 5 0 -19.1 0 -18.8 -19.3 01/23/2005 04:20:00 10.9 1.1 12.6 8.4 10.7 1.2 13 8.4 0.4 0 0.4 0.4 28 4 29 305 5 0 5 0 -19.3 0.1 -19 -19.5 01/23/2005 04:30:00 9.1 0.7 11.8 7.6 9.1 0.8 11.5 7.2 0.4 0 0.4 0.4 31 5 30 305 5 0 5 0 -19.6 0 -19 -19.5 01/23/2005 04:40:00 8.7 0.5 9.5 7.2 8.7 0.7 10.7 6.5 0.4 0 0.4 0.4 33 4 33 305 4 0 4 0 -19.7 0 -19 -19.7 01/23/2005 04:50:00 8.7 0.4 9.5 7.2 8.5 0.5 10.7 7.2 0.4 0 0.4 0.4 23 4 32 305 4 0 4 0 -19.7 0 -19 -19.9 01/23/2005 05:00:00 8.8 0.5 9.9 6.8 8.8 0.7 10.7 6.8 0.4 0 0.4 0.4 22 3 23 305 4 0 4 0 -19.6 0 -19.2 -19.7 01/23/2005 05:10:00 8.5 0.7 9.5 6.5 8.4 0.7 10.7 5.7 0.4 0 0.4 0.4 23 4 20 305 4 0 4 0 -19.5 0 -19 -19.5 01/23/2005 05:20:00 8.8 0.5 11.1 7.2 8.7 0.6 11.1 6.8 0.4 0 0.4 0.4 23 4 23 305 4 0 4 0 -19.4 0 -19.3 -19.5 01/23/2005 05:30:00 8.9 0.8 11.8 7.2 8.8 1 12.2 6.8 0.4 0 0.4 0.4 27 4 23 305 4 0 4 0 -19.6 0 -19.5 -19.5 01/23/2005 05:40:00 10.4 1.1 12.6 8 10.3 1.1 12.6 8.4 0.4 0 0.4 0.4 28 4 27 305 4 0 4 0 -19.7 0 -19.5 -19.7 01/23/2005 05:50:00 10.6 1.1 12.6 8.4 10.6 1.2 12.6 8.4 0.4 0 0.4 0.4 27 5 24 305 4 0 4 0 -19.8 0.1 -19.5 -20.1 01/23/2005 06:00:00 11.1 1 13 8.4 11 1.1 13 8.4 0.4 0 0.4 0.4 29 3 29 305 4 0 4 0 -20 0.1 -19.7 -20.1 01/23/2005 06:10:00 10.9 1.1 13 8 10.7 1.2 13 7.6 0.4 0 0.4 0.4 28 4 29 305 4 0 4 0 -20 0 -19.9 -20.1 01/23/2005 06:20:00 11.1 1 13 8.8 11 1 13 8.4 0.4 0 0.4 0.4 29 4 27 305 4 0 4 0 -20 0 -19.9 -20.1 01/23/2005 06:30:00 11.7 0.8 13.7 9.1 11.6 0.8 14.1 8.8 0.4 0 0.4 0.4 31 4 29 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 06:40:00 11.3 1 13.3 8.8 11.3 1.1 13.3 8.4 0.4 0 0.4 0.4 31 4 31 305 4 0 4 0 -20 0 -19.7 -20.1 01/23/2005 06:50:00 11.6 1 13.7 8.8 11.5 1.1 13.3 8.4 0.4 0 0.4 0.4 31 3 32 305 4 0 4 0 -20 0 -19.9 -20.1 01/23/2005 07:00:00 11 1.2 13 8.8 11.1 1.3 13.3 8.4 0.4 0 0.4 0.4 34 5 25 305 4 0 4 0 -20 0.1 -19.5 -20.1 01/23/2005 07:10:00 11.2 1 13.3 8.4 11.1 1.1 13.3 8.4 0.4 0 0.4 0.4 30 5 31 305 4 0 4 0 -20.1 0 -19.9 -20.1 01/23/2005 07:20:00 11.5 1 13 8.8 11.5 1 13.7 8.8 0.4 0 0.4 0.4 28 4 32 305 4 0 4 0 -20.2 0 -20.1 -20.2 01/23/2005 07:30:00 10.7 1.1 12.6 8 10.7 1.2 13 8 0.4 0 0.4 0.4 25 4 24 305 4 0 4 0 -20.2 0 -20.1 -20.4 01/23/2005 07:40:00 10.4 1.1 12.6 7.6 10.3 1.1 12.6 8 0.4 0 0.4 0.4 27 4 29 305 4 0 4 0 -20.3 0 -20.1 -20.4 01/23/2005 07:50:00 9.1 0.8 11.8 6.8 9 0.9 11.5 6.8 0.4 0 0.4 0.4 25 4 21 305 4 0 4 0 -20.2 0 -20.1 -20.2 01/23/2005 08:00:00 10.5 0.9 12.6 8.4 10.5 1 12.6 8.4 0.4 0 0.4 0.4 29 4 32 305 4 0 4 0 -20.2 0 -19.5 -20.2 01/23/2005 08:10:00 10.8 1 12.6 8.8 10.8 1 13 8.4 0.4 0 0.4 0.4 29 4 30 305 4 0 4 0 -20.2 0 -19.5 -20.2 01/23/2005 08:20:00 10.4 1.1 13 8.4 10.4 1.2 13.3 8 0.4 0 0.4 0.4 26 5 32 305 4 0 4 0 -20.1 0 -19.5 -20.1 01/23/2005 08:30:00 10.6 1.1 13.3 8.8 10.6 1.2 13.3 8.4 0.4 0 0.4 0.4 23 4 20 305 4 0 4 0 -20.2 0 -19.5 -20.2 01/23/2005 08:40:00 12.2 0.8 14.1 9.1 12.2 1 14.1 8.8 0.4 0 0.4 0.4 25 4 32 305 4 0 4 0 -20.2 0 -19.5 -20.2 01/23/2005 08:50:00 12.1 1 14.5 9.1 12.1 1 14.1 8.8 0.4 0 0.4 0.4 28 4 24 305 4 0 4 0 -20.1 0 -19.5 -20.1 01/23/2005 09:00:00 12.4 1.1 14.5 8.8 12.3 1.2 14.5 8.8 0.4 0 0.4 0.4 30 4 36 305 4 0 4 0 -20.2 0 -19.5 -20.2 01/23/2005 09:10:00 12 1.1 14.1 8.8 11.9 1.2 14.1 8.4 0.4 0 0.4 0.4 30 4 33 305 4 0 4 0 -20.2 0 -20.1 -20.2 01/23/2005 09:20:00 10.7 1.1 13 8.4 10.7 1.1 13 8.4 0.4 0 0.4 0.4 29 5 33 305 4 0 4 0 -20.2 0 -20.1 -20.1 01/23/2005 09:30:00 11.4 1 13.3 8.8 11.4 1 13.3 8.4 0.4 0 0.4 0.4 26 3 24 305 4 0 4 0 -20.2 0 -20.1 -20.4 01/23/2005 09:40:00 11.4 1.1 13.7 8.8 11.3 1.1 13.7 8.4 0.4 0 0.4 0.4 29 4 30 305 4 0 4 0 -20.2 0 -20.1 -20.4 01/23/2005 09:50:00 10.7 1.3 13.7 8.4 10.7 1.3 14.1 8 0.4 0 0.4 0.4 27 5 26 305 4 0 4 0 -20.2 0 -20.1 -20.2 01/23/2005 10:00:00 10 1 12.2 8 10.1 1 12.6 8.4 0.4 0 0.4 0.4 25 4 23 305 4 0 4 0 -20.2 0 -19.5 -20.2 01/23/2005 10:10:00 10.8 1.3 13.3 8 10.7 1.3 13.7 8 0.4 0 0.4 0.4 27 5 33 305 4 0 4 0 -20.2 0 -19.7 -20.4 01/23/2005 10:20:00 11.5 1.1 13.3 8.8 11.5 1.1 13.7 8.4 0.4 0 0.4 0.4 30 5 29 305 4 0 4 0 -20.2 0 -19.7 -20.4 01/23/2005 10:30:00 11 1.2 13.3 8.4 11 1.3 13.7 7.6 0.4 0 0.4 0.4 28 5 31 305 4 0 4 0 -20.3 0 -19.9 -20.4 01/23/2005 10:40:00 9.5 1 12.2 7.6 9.4 1.1 12.6 7.2 0.4 0 0.4 0.4 28 5 30 305 4 0 4 0 -20.3 0 -19.9 -20.4 01/23/2005 10:50:00 10.6 1.2 13.7 8.4 10.6 1.3 14.1 8 0.4 0 0.4 0.4 28 5 29 305 4 0 4 0 -20.3 0 -19.9 -20.6 01/23/2005 11:00:00 11.4 1.1 13.7 8.8 11.4 1.2 13.7 8.4 0.4 0 0.4 0.4 27 4 26 305 4 0 4 0 -20.3 0 -19.9 -20.4 01/23/2005 11:10:00 11.6 1.2 14.9 8.4 11.5 1.3 14.9 8.4 0.4 0 0.4 0.4 28 5 27 305 4 0 4 0 -20.2 0 -20.1 -20.2 01/23/2005 11:20:00 13 0.9 15.3 10.3 12.9 1 15.3 10.3 0.4 0 0.4 0.4 27 4 28 305 4 0 4 0 -20.2 0 -20.1 -20.2 01/23/2005 11:30:00 12.1 1.1 14.9 8.8 12 1.2 14.9 8.8 0.4 0 0.4 0.4 31 5 29 305 4 0 4 0 -20.2 0 -19.9 -20.2 01/23/2005 11:40:00 11.9 1.1 14.5 8.8 11.8 1.2 14.5 8.8 0.4 0 0.4 0.4 30 5 28 305 4 0 4 0 -20 0 -19.9 -20.1 01/23/2005 11:50:00 12.8 1.1 16.4 9.9 12.9 1.2 16.1 9.5 0.4 0 0.4 0.4 30 4 34 305 4 0 4 0 -20 0 -19.9 -20.1 01/23/2005 12:00:00 12.7 1.2 15.3 9.1 12.7 1.3 15.6 8.8 0.4 0 0.4 0.4 33 4 28 305 4 0 4 0 -19.9 0 -19.5 -20.1 01/23/2005 12:10:00 12.7 1.2 16.1 9.1 12.6 1.2 15.6 9.1 0.4 0 0.4 0.4 34 5 32 305 4 0 4 0 -19.9 0 -19.5 -20.1 01/23/2005 12:20:00 13.6 1 16.1 11.1 13.5 1.1 16.1 9.9 0.4 0 0.4 0.4 32 4 31 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 12:30:00 13.2 1 16.1 10.7 13.2 1 16.1 10.3 0.4 0 0.4 0.4 30 4 39 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 12:40:00 13.7 1.1 16.1 10.7 13.5 1.2 16.4 10.7 0.4 0 0.4 0.4 29 4 35 305 4 0 4 0 -19.8 0 -19.5 -20.1 01/23/2005 12:50:00 14.3 1 16.1 11.5 14.2 1.1 16.8 11.8 0.4 0 0.4 0.4 32 5 31 305 4 0 4 0 -19.8 0 -19.5 -20.1 01/23/2005 13:00:00 13.7 1.2 16.1 10.7 13.7 1.3 16.4 10.3 0.4 0 0.4 0.4 32 4 29 305 4 0 4 0 -19.8 0 -19.5 -19.9 01/23/2005 13:10:00 14.5 1.3 17.6 9.9 14.3 1.5 17.6 10.3 0.4 0 0.4 0.4 32 4 37 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 13:20:00 14.9 1.3 17.2 11.1 14.8 1.4 17.9 10.7 0.4 0 0.4 0.4 33 4 37 305 4 0 4 0 -19.7 0 -19.2 -19.9 01/23/2005 13:30:00 15.2 1 17.6 12.2 15.2 1.2 17.6 11.8 0.4 0 0.4 0.4 33 4 35 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 13:40:00 14.6 1.2 16.8 11.8 14.6 1.3 17.2 11.5 0.4 0 0.4 0.4 33 4 29 305 4 0 4 0 -19.6 0 -19.5 -19.7 01/23/2005 13:50:00 14.9 1.3 17.9 11.1 14.6 1.4 18.3 10.3 0.4 0 0.4 0.4 33 5 35 305 4 0 4 0 -19.6 0 -19.3 -19.5 01/23/2005 14:00:00 15.4 1.2 17.9 12.2 15.2 1.4 17.9 11.8 0.4 0 0.4 0.4 35 4 33 305 4 0 4 0 -19.6 0 -19.3 -19.5 01/23/2005 14:10:00 16.3 0.9 18.7 13.3 16.2 1.1 18.3 13 0.4 0 0.4 0.4 36 4 33 305 4 0 4 0 -19.6 0 -19.5 -19.7 01/23/2005 14:20:00 16.3 1.2 19.1 12.6 16.2 1.3 18.7 11.8 0.4 0 0.4 0.4 35 4 33 305 4 0 4 0 -19.6 0 -19.3 -19.7 01/23/2005 14:30:00 16 1.5 19.5 11.1 15.8 1.6 19.1 11.8 0.4 0 0.4 0.4 35 4 28 305 4 0 4 0 -19.6 0 -19.3 -19.7 01/23/2005 14:40:00 14.8 1.2 17.9 11.8 14.7 1.3 17.6 11.5 0.4 0 0.4 0.4 37 5 33 305 5 0 5 0 -19.5 0 -19.3 -19.5 01/23/2005 14:50:00 16.3 1.5 19.5 12.2 16.1 1.7 19.9 12.6 0.4 0 0.4 0.4 38 5 36 305 5 0 5 0 -19.5 0 -19.3 -19.5 01/23/2005 15:00:00 16.1 1.7 20.6 12.6 15.9 1.8 20.2 12.2 0.4 0 0.4 0.4 39 5 41 305 4 0 4 0 -19.4 0.1 -19.2 -19.5 01/23/2005 15:10:00 16.6 1.4 19.5 13 16.5 1.5 19.9 12.6 0.4 0 0.4 0.4 34 5 42 305 4 0 4 0 -19.4 0 -19.2 -19.5 01/23/2005 15:20:00 17 1.3 20.2 13 16.8 1.4 19.9 13.3 0.4 0 0.4 0.4 40 4 37 305 5 0 5 0 -19.3 0 -19 -19.5 01/23/2005 15:30:00 17.2 1.3 19.5 14.1 16.9 1.3 20.2 13.7 0.4 0 0.4 0.4 38 4 33 305 4 0 5 0 -19.4 0 -19.2 -19.5 01/23/2005 15:40:00 16.9 1.5 20.2 13.7 16.8 1.6 20.2 13.3 0.4 0 0.4 0.4 39 5 43 305 5 0 5 0 -19.3 0 -19 -19.5 01/23/2005 15:50:00 17.9 1.1 20.2 14.1 17.8 1.1 20.2 14.9 0.4 0 0.4 0.4 38 4 37 305 4 0 5 0 -19.4 0 -19.2 -19.5 01/23/2005 16:00:00 17.3 1.5 20.2 13 17.1 1.5 21.4 12.6 0.4 0 0.4 0.4 37 4 33 305 4 0 5 0 -19.4 0 -19.2 -19.5 01/23/2005 16:10:00 17.2 1.1 19.5 14.1 17 1.1 19.9 13.3 0.4 0 0.4 0.4 36 4 43 305 4 0 5 0 -19.4 0 -19.2 -19.5 01/23/2005 16:20:00 16.8 1.5 20.2 13 16.7 1.5 20.6 13.3 0.4 0 0.4 0.4 41 5 31 305 5 0 5 0 -19.3 0 -19.2 -19.5 01/23/2005 16:30:00 16.6 1.4 20.2 13 16.6 1.5 20.6 13 0.4 0 0.4 0.4 39 5 45 305 5 0 5 0 -19.3 0 -19 -19.5 01/23/2005 16:40:00 18 1.7 21.8 12.6 18 1.8 22.1 13 0.4 0 0.4 0.4 40 5 40 305 4 0 4 0 -19.3 0 -19 -19.5 01/23/2005 16:50:00 16.8 1.7 21 13 16.7 1.7 21 12.6 0.4 0 0.4 0.4 42 4 39 305 4 0 4 0 -19.5 0 -19.2 -19.5 01/23/2005 17:00:00 16.3 1.3 19.9 13 16.2 1.4 19.9 12.6 0.4 0 0.4 0.4 40 5 35 305 4 0 4 0 -19.5 0 -19.3 -19.5 01/23/2005 17:10:00 17 1.5 20.2 13 16.9 1.5 20.2 12.6 0.4 0 0.4 0.4 39 4 39 305 4 0 4 0 -19.5 0 -19.3 -19.5 01/23/2005 17:20:00 17.3 1.2 20.2 13.7 17.3 1.2 20.6 13.7 0.4 0 0.4 0.4 39 4 41 305 4 0 4 0 -19.6 0 -19.2 -19.7 01/23/2005 17:30:00 15.6 1.2 18.3 12.6 15.5 1.3 18.3 12.6 0.4 0 0.4 0.4 38 5 39 305 4 0 4 0 -19.6 0 -19.5 -19.7 01/23/2005 17:40:00 17.2 1.3 20.2 13.3 17.1 1.4 20.2 13 0.4 0 0.4 0.4 40 4 42 305 4 0 4 0 -19.6 0 -19.5 -19.7 01/23/2005 17:50:00 17.2 1.2 20.6 13.7 16.9 1.3 20.6 14.1 0.4 0 0.4 0.4 39 5 39 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 18:00:00 16.8 1.5 20.2 13.7 16.7 1.5 20.6 13.3 0.4 0 0.4 0.4 39 5 37 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 18:10:00 16.5 1.5 19.9 12.6 16.5 1.5 20.2 12.6 0.4 0 0.4 0.4 37 5 42 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 18:20:00 15.9 1.3 19.1 12.6 15.7 1.5 19.5 12.2 0.4 0 0.4 0.4 37 5 36 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 18:30:00 15.2 1.5 19.1 12.2 15 1.5 19.1 11.5 0.4 0 0.4 0.4 36 5 38 305 4 0 4 0 -19.6 0 -19.5 -19.7 01/23/2005 18:40:00 15.8 1.2 19.9 12.6 15.6 1.3 19.1 12.2 0.4 0 0.4 0.4 36 4 31 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 18:50:00 16 1.2 18.7 12.6 15.9 1.2 18.7 12.6 0.4 0 0.4 0.4 36 5 35 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 19:00:00 15.6 1.3 18.7 12.6 15.5 1.4 19.5 12.6 0.4 0 0.4 0.4 37 5 37 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 19:10:00 16.4 2 21.4 12.2 16.2 2.1 21 12.2 0.4 0 0.4 0.4 40 5 44 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 19:20:00 16.5 1.6 20.6 13 16.4 1.7 20.2 13 0.4 0 0.4 0.4 39 5 43 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 19:30:00 16.8 1.7 20.6 13 16.8 1.7 21.4 12.2 0.4 0 0.4 0.4 39 5 35 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/23/2005 19:40:00 17.8 1.5 21.4 14.1 17.7 1.6 21 13.7 0.4 0 0.4 0.4 40 4 43 305 4 0 4 0 -19.8 0 -19.5 -19.9 01/23/2005 19:50:00 18.3 1.3 22.6 14.1 18.1 1.5 22.6 14.1 0.4 0 0.4 0.4 39 5 34 305 4 0 4 0 -19.8 0 -19.5 -20.1 01/23/2005 20:00:00 16.6 1.5 19.9 13.3 16.4 1.5 20.2 13 0.4 0 0.4 0.4 39 5 37 305 4 0 4 0 -19.8 0 -19.3 -20.1 01/23/2005 20:10:00 16.9 1.5 20.2 12.6 16.8 1.6 20.2 13 0.4 0 0.4 0.4 38 5 41 305 4 0 4 0 -19.8 0 -19.3 -20.1 01/23/2005 20:20:00 17.2 1.5 20.6 13.3 17 1.6 20.6 13 0.4 0 0.4 0.4 40 5 35 305 4 0 4 0 -19.9 0 -19.5 -20.1 01/23/2005 20:30:00 17.6 1.4 20.6 13.3 17.4 1.5 20.2 11.8 0.4 0 0.4 0.4 39 4 43 305 4 0 4 0 -19.9 0 -19.3 -20.1 01/23/2005 20:40:00 17 1.5 20.2 13.3 16.8 1.5 21 13 0.4 0 0.4 0.4 40 4 38 305 4 0 4 0 -19.9 0 -19.3 -20.1 01/23/2005 20:50:00 17.2 1.5 20.2 12.6 17.1 1.5 19.9 13 0.4 0 0.4 0.4 38 4 39 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 21:00:00 17.2 1.5 21.4 14.1 17.1 1.5 21 13.7 0.4 0 0.4 0.4 40 5 40 305 4 0 4 0 -20 0 -19.7 -20.1 01/23/2005 21:10:00 17 1.3 19.5 13 16.8 1.3 19.9 13.3 0.4 0 0.4 0.4 41 5 39 305 4 0 4 0 -20 0 -19.9 -20.1 01/23/2005 21:20:00 16.1 1.3 19.1 12.2 15.9 1.4 19.9 12.2 0.4 0 0.4 0.4 38 5 37 305 4 0 4 0 -20 0 -19.3 -20.1 01/23/2005 21:30:00 17.4 1.4 20.6 13 17.1 1.3 20.2 13.3 0.4 0 0.4 0.4 39 5 44 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 21:40:00 17.4 1.5 21 14.1 17.3 1.5 21 14.1 0.4 0 0.4 0.4 41 4 37 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 21:50:00 16.4 1.3 19.5 13.3 16.4 1.4 19.9 13 0.4 0 0.4 0.4 41 4 35 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 22:00:00 16.5 1.8 20.6 12.2 16.3 1.9 20.2 11.5 0.4 0 0.4 0.4 40 5 43 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 22:10:00 17.3 1.3 20.2 13.3 17.2 1.4 20.2 12.6 0.4 0 0.4 0.4 41 4 39 305 4 0 4 0 -19.8 0 -19.5 -20.1 01/23/2005 22:20:00 15.7 1.1 17.9 12.6 15.6 1.2 18.3 12.6 0.4 0 0.4 0.4 44 6 40 305 4 0 4 0 -19.8 0 -19.5 -20.1 01/23/2005 22:30:00 15.4 1.5 17.9 11.5 15.1 1.6 17.9 11.1 0.4 0 0.4 0.4 37 5 33 305 4 0 4 0 -19.9 0.1 -19.5 -20.1 01/23/2005 22:40:00 17 1.5 20.6 13.7 16.9 1.5 21 13.3 0.4 0 0.4 0.4 36 5 31 305 4 0 4 0 -20 0 -19.7 -20.1 01/23/2005 22:50:00 17.1 1.9 20.6 11.1 16.9 2 21 11.5 0.4 0 0.4 0.4 39 6 42 305 4 0 4 0 -20 0 -19.7 -20.1 01/23/2005 23:00:00 15.6 1.7 19.1 11.8 15.5 1.8 19.5 11.5 0.4 0 0.4 0.4 36 6 30 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 23:10:00 17.1 1.5 20.6 13.3 17 1.6 21 13.3 0.4 0 0.4 0.4 36 4 36 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 23:20:00 16.2 1.5 20.6 12.2 16 1.7 20.6 12.2 0.4 0 0.4 0.4 40 6 44 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 23:30:00 16.5 2.1 21.4 11.8 16.4 2.3 21.8 11.5 0.4 0 0.4 0.4 40 5 39 305 4 0 4 0 -19.9 0 -19.7 -20.1 01/23/2005 23:40:00 17.5 1.5 21 13.3 17.3 1.5 21.8 13.7 0.4 0 0.4 0.4 42 5 44 305 4 0 4 0 -19.8 0 -19.3 -20.1 01/23/2005 23:50:00 17.1 1.4 21 12.6 17 1.4 20.2 13.3 0.4 0 0.4 0.4 43 5 39 305 4 0 4 0 -19.7 0 -19.5 -19.9 01/24/2005 00:00:00 17.4 1.8 21.8 12.6 17.2 1.8 21.4 12.2 0.4 0 0.4 0.4 41 5 36 305 4 0 4 0 -19.6 0 -19.3 -19.9 01/24/2005 00:10:00 17.2 1.7 21 12.6 17 1.9 21.4 11.5 0.4 0 0.4 0.4 39 5 31 305 4 0 4 0 -19.5 0 -19.3 -19.5 01/24/2005 00:20:00 16.6 1.8 21.4 12.6 16.5 1.9 21.4 11.8 0.4 0 0.4 0.4 39 6 36 305 4 0 4 0 -19.4 0 -19.2 -19.5 01/24/2005 00:30:00 16.1 1.7 19.9 11.8 15.9 1.7 19.5 11.8 0.4 0 0.4 0.4 42 5 43 305 4 0 4 0 -19.6 0 -19.3 -19.7 01/24/2005 00:40:00 16.5 1.9 22.1 12.6 16.4 2 22.9 12.2 0.4 0 0.4 0.4 40 5 32 305 4 0 4 0 -19.5 0 -19.2 -19.5 01/24/2005 00:50:00 19.8 1.5 23.3 16.1 19.7 1.5 23.3 15.6 0.4 0 0.4 0.4 41 4 44 305 4 0 4 0 -19.6 0.1 -19 -19.9 01/24/2005 01:00:00 18.6 1.3 21 14.9 18.5 1.3 21.4 13.7 0.4 0 0.4 0.4 40 4 37 305 4 0 4 0 -19.6 0 -19 -19.5 01/24/2005 01:10:00 17.9 1.2 20.6 13.7 17.7 1.5 21 14.1 0.4 0 0.4 0.4 36 5 41 305 4 0 4 0 -19.5 0 -19.3 -19.5 01/24/2005 01:20:00 18.8 1.5 22.1 14.1 18.6 1.6 22.9 14.1 0.4 0 0.4 0.4 38 5 39 305 4 0 4 0 -19.5 0 -19 -19.5 01/24/2005 01:30:00 19 1.6 22.6 14.5 18.9 1.7 22.6 14.1 0.4 0 0.4 0.4 36 5 40 305 4 0 4 0 -19.6 0 -19.3 -19.7 01/24/2005 01:40:00 19.5 1.4 22.6 16.1 19.4 1.5 22.6 15.3 0.4 0 0.4 0.4 38 4 39 305 4 0 4 0 -19.6 0 -19.3 -19.7 01/24/2005 01:50:00 19.6 1.8 22.9 14.1 19.3 1.9 22.9 13.7 0.4 0 0.4 0.4 36 5 42 305 4 0 4 0 -19.6 0 -19.3 -19.5 01/24/2005 02:00:00 19.8 1.8 23.3 14.5 19.5 1.9 24.4 14.9 0.4 0 0.4 0.4 37 5 38 305 4 0 4 0 -19.6 0 -19.3 -19.7 01/24/2005 02:10:00 19.4 1.6 22.9 15.3 19.2 1.6 23.3 14.9 0.4 0 0.4 0.4 36 5 41 305 4 0 4 0 -19.4 0 -19 -19.5 01/24/2005 02:20:00 19.7 1.5 22.9 15.3 19.4 1.6 23.3 14.9 0.4 0 0.4 0.4 34 4 33 305 4 0 4 0 -19.4 0 -19 -19.5 01/24/2005 02:30:00 19.8 2 23.7 14.5 19.6 2 24.4 14.9 0.4 0 0.4 0.4 35 5 44 305 4 0 4 0 -19.3 0 -19 -19.5 01/24/2005 02:40:00 19.1 1.7 23.3 14.9 19 1.8 22.9 14.9 0.4 0 0.4 0.4 40 5 41 305 4 0 4 0 -19.3 0.1 -19 -19.5 01/24/2005 02:50:00 18.5 1.7 22.1 14.1 18.3 1.8 22.9 13.3 0.4 0 0.4 0.4 42 5 43 305 4 0 4 0 -19.3 0 -19 -19.5 01/24/2005 03:00:00 18.7 1.6 23.3 13.7 18.5 1.7 22.9 14.1 0.4 0 0.4 0.4 44 5 40 305 4 0 4 0 -19.4 0 -19.2 -19.5 01/24/2005 03:10:00 18.9 1.5 22.6 14.9 18.7 1.5 22.6 14.5 0.4 0 0.4 0.4 45 5 47 305 4 0 4 0 -19.5 0 -19.2 -19.5 01/24/2005 03:20:00 18.3 1.7 22.1 14.1 18.2 1.6 21.8 13.7 0.4 0 0.4 0.4 45 5 46 305 4 0 4 0 -19.5 0 -19.2 -19.5 01/24/2005 03:30:00 17.6 1.7 21.8 13 17.4 1.8 22.1 13 0.4 0 0.4 0.4 40 5 37 305 4 0 4 0 -19.3 0 -19 -19.5 01/24/2005 03:40:00 17.8 1.4 21.8 14.1 17.8 1.5 21.8 13.3 0.4 0 0.4 0.4 44 4 35 305 4 0 4 0 -19.5 0.1 -19 -19.5 01/24/2005 03:50:00 19.1 1.3 21.8 14.1 18.9 1.4 21.8 14.1 0.4 0 0.4 0.4 45 5 44 305 4 0 4 0 -19.6 0 -19.3 -19.5 01/24/2005 04:00:00 18.3 1.4 21.4 14.1 18.1 1.5 21.4 13.7 0.4 0 0.4 0.4 43 5 44 305 4 0 4 0 -19.5 0 -19.2 -19.5 01/24/2005 04:10:00 18.1 1.4 21.8 14.1 17.8 1.4 21.8 14.1 0.4 0 0.4 0.4 42 5 43 305 4 0 4 0 -19.5 0 -19.2 -19.5 01/24/2005 04:20:00 17.5 1.4 20.2 14.1 17.3 1.5 21 13.3 0.4 0 0.4 0.4 43 5 40 305 4 0 4 0 -19.6 0 -19.3 -19.5 01/24/2005 04:30:00 16.6 1.5 19.9 12.2 16.4 1.5 20.2 12.2 0.4 0 0.4 0.4 43 5 38 305 4 0 4 0 -19.5 0 -19.3 -19.5 01/24/2005 04:40:00 18.1 1.3 21.4 14.5 17.9 1.4 21.4 14.5 0.4 0 0.4 0.4 44 4 51 305 4 0 4 0 -19.5 0 -19.3 -19.5 01/24/2005 04:50:00 17.9 1.3 21.4 14.5 17.6 1.4 21 14.5 0.4 0 0.4 0.4 42 5 35 305 4 0 4 0 -19.6 0 -19 -19.7 01/24/2005 05:00:00 18.6 1.7 21.8 13.7 18.4 1.7 22.1 14.5 0.4 0 0.4 0.4 43 4 44 305 4 0 4 0 -19.5 0 -19 -19.5 01/24/2005 05:10:00 18.3 1.4 21.4 14.1 18.1 1.5 21.8 14.1 0.4 0 0.4 0.4 45 4 43 305 4 0 4 0 -19.6 0 -19.3 -19.7 01/24/2005 05:20:00 17 1.5 21 13.3 16.9 1.5 21 13.3 0.4 0 0.4 0.4 44 5 51 305 4 0 4 0 -19.6 0 -19.3 -19.7 01/24/2005 05:30:00 17.4 1.3 20.6 13.7 17.1 1.5 20.2 13.3 0.4 0 0.4 0.4 44 4 44 305 4 0 4 0 -19.5 0 -19.2 -19.5 01/24/2005 05:40:00 17 1.7 20.2 12.6 16.7 1.7 20.2 12.2 0.4 0 0.4 0.4 44 5 46 305 4 0 4 0 -19.5 0 -19.2 -19.5 01/24/2005 05:50:00 18 1.2 22.1 14.9 17.8 1.3 21.8 14.5 0.4 0 0.4 0.4 45 4 50 305 4 0 4 0 -19.5 0 -19.3 -19.5 01/24/2005 06:00:00 17.8 1.4 21.4 14.5 17.7 1.5 21.4 13.7 0.4 0 0.4 0.4 46 5 50 305 4 0 4 0 -19.5 0 -19.2 -19.5 01/24/2005 06:10:00 16.4 1.3 19.9 13 16.3 1.3 19.9 13 0.4 0 0.4 0.4 45 5 45 305 4 0 4 0 -19.5 0 -19.3 -19.5 01/24/2005 06:20:00 18.2 2 22.6 13.3 17.9 2 22.6 13.3 0.4 0 0.4 0.4 42 6 40 305 4 0 4 0 -19.5 0.1 -19.2 -19.5 01/24/2005 06:30:00 18.3 1.7 23.3 13.3 18.1 1.9 23.3 13.3 0.4 0 0.4 0.4 43 5 27 305 4 0 4 0 -19.5 0 -19.2 -19.5 01/24/2005 06:40:00 17.9 1.4 21.4 13 17.7 1.4 21 12.2 0.4 0 0.4 0.4 43 5 46 305 4 0 4 0 -19.6 0 -19.3 -19.5 01/24/2005 06:50:00 16.4 1.5 19.9 12.2 16.2 1.7 19.9 12.2 0.4 0 0.4 0.4 42 5 41 305 4 0 4 0 -19.6 0 -19.5 -19.7 01/24/2005 07:00:00 16.9 1.6 20.2 12.6 16.8 1.7 20.2 12.2 0.4 0 0.4 0.4 41 5 44 305 4 0 4 0 -19.6 0 -19.3 -19.7 01/24/2005 07:10:00 15.4 1.1 17.9 13 15.2 1.2 19.1 12.2 0.4 0 0.4 0.4 46 5 46 305 4 0 4 0 -19.6 0 -19 -19.7 01/24/2005 07:20:00 15 1.2 18.3 12.2 15 1.2 17.9 12.2 0.4 0 0.4 0.4 43 5 44 305 4 0 4 0 -19.6 0 -19.3 -19.7 01/24/2005 07:30:00 17.4 1.7 21.4 13 17.2 1.8 20.6 12.6 0.4 0 0.4 0.4 43 5 38 305 4 0 4 0 -19.6 0 -19.5 -19.7 01/24/2005 07:40:00 16.5 1.7 20.2 11.5 16.3 1.8 20.6 11.1 0.4 0 0.4 0.4 44 4 40 305 4 0 4 0 -19.7 0 -19.5 -19.7 01/24/2005 07:50:00 17 1.2 19.9 14.1 17 1.3 20.2 13.3 0.4 0 0.4 0.4 41 5 42 305 4 0 4 0 -19.7 0 -19.5 -19.7 01/24/2005 08:00:00 16.1 1.3 19.5 13 16 1.3 19.5 13 0.4 0 0.4 0.4 42 4 38 305 4 0 4 0 -19.6 0 -19.5 -19.7 01/24/2005 08:10:00 16 1.3 19.9 12.6 15.7 1.3 19.5 12.6 0.4 0 0.4 0.4 43 5 38 305 4 0 4 0 -19.6 0 -19.5 -19.7 01/24/2005 08:20:00 16.9 1.4 20.2 13 16.8 1.5 20.6 13 0.4 0 0.4 0.4 44 5 45 305 4 0 4 0 -19.5 0 -19.3 -19.5 01/24/2005 08:30:00 16.4 1.7 19.9 11.8 16.3 1.8 20.6 12.2 0.4 0 0.4 0.4 42 5 44 305 4 0 4 0 -19.5 0 -19.3 -19.5 01/24/2005 08:40:00 17.1 1.3 19.5 13.7 17 1.5 20.2 13.3 0.4 0 0.4 0.4 41 4 40 305 4 0 4 0 -19.4 0 -19.2 -19.5 01/24/2005 08:50:00 17.5 2.1 21.4 12.2 17.3 2.3 21.8 11.8 0.4 0 0.4 0.4 41 4 45 305 4 0 4 0 -19.4 0 -19.2 -19.5 01/24/2005 09:00:00 17.2 1.5 19.9 13.3 17.1 1.5 20.2 13 0.4 0 0.4 0.4 43 4 45 305 4 0 4 0 -19.4 0 -19 -19.5 01/24/2005 09:10:00 16.9 1.5 19.9 13.7 16.8 1.5 19.9 13.3 0.4 0 0.4 0.4 42 4 39 305 4 0 4 0 -19.3 0 -19 -19.5 01/24/2005 09:20:00 17.2 1.6 20.6 12.6 16.9 1.7 20.6 12.6 0.4 0 0.4 0.4 41 5 40 305 4 0 4 0 -19.4 0 -19 -19.5 01/24/2005 09:30:00 18.2 1.4 21.4 14.5 17.9 1.5 21 13.7 0.4 0 0.4 0.4 42 4 43 305 4 0 4 0 -19.3 0 -19 -19.5 01/24/2005 09:40:00 17 1.6 21 13.3 16.9 1.6 21 13.3 0.4 0 0.4 0.4 42 5 40 305 4 0 4 0 -19.4 0 -19.2 -19.5 01/24/2005 09:50:00 17.3 1.3 22.1 14.1 17 1.5 21.8 13.3 0.4 0 0.4 0.4 43 5 43 305 4 0 4 0 -19.3 0 -19 -19.5 01/24/2005 10:00:00 17.6 1.5 21.8 13.7 17.5 1.5 21.4 13.7 0.4 0 0.4 0.4 42 5 41 305 4 0 4 0 -19.3 0 -19 -19.5 01/24/2005 10:10:00 17.2 1.7 21 13.7 16.9 1.8 21.4 13.3 0.4 0 0.4 0.4 43 4 45 305 4 0 4 0 -19.1 0 -19 -19.2 01/24/2005 10:20:00 17.2 1.6 21.4 13 17.1 1.7 21.4 13.3 0.4 0 0.4 0.4 44 5 50 305 4 0 4 0 -19.1 0 -19 -19.2 01/24/2005 10:30:00 18 1.6 21 14.1 17.7 1.6 21 14.1 0.4 0 0.4 0.4 43 5 37 305 4 0 4 0 -19.1 0 -19 -19.2 01/24/2005 10:40:00 18.1 1.3 21 14.9 17.8 1.5 21.4 13.7 0.4 0 0.4 0.4 45 4 40 305 4 0 4 0 -19.1 0 -18.8 -19.2 01/24/2005 10:50:00 16 1.3 19.1 13 15.8 1.3 19.1 12.6 0.4 0 0.4 0.4 41 5 36 305 4 0 4 0 -19.1 0 -18.8 -19.2 01/24/2005 11:00:00 17.4 1.6 21.4 13 17.2 1.5 21 13 0.4 0 0.4 0.4 44 5 47 305 4 0 4 0 -19 0 -18.8 -19.2 01/24/2005 11:10:00 17.2 1.5 20.6 13.7 17 1.4 21.4 13.3 0.4 0 0.4 0.4 41 5 49 305 4 0 4 0 -19 0 -18.8 -19 01/24/2005 11:20:00 16.6 1.3 19.5 13 16.4 1.5 19.5 12.2 0.4 0 0.4 0.4 42 4 46 305 4 0 4 0 -19.1 0 -18.8 -19.2 01/24/2005 11:30:00 16.9 1.2 19.9 13.3 16.8 1.2 20.2 13.3 0.4 0 0.4 0.4 42 5 35 305 4 0 4 0 -19.1 0 -19 -19.2 01/24/2005 11:40:00 16.1 1.5 20.2 12.6 15.9 1.7 20.2 11.8 0.4 0 0.4 0.4 45 5 51 305 4 0 4 0 -19.1 0 -18.8 -19.2 01/24/2005 11:50:00 16.5 1.5 20.6 12.6 16.4 1.5 19.9 13 0.4 0 0.4 0.4 44 5 43 305 4 0 4 0 -19.1 0 -19 -19.2 01/24/2005 12:00:00 17 1.6 20.6 13 16.8 1.6 20.2 12.6 0.4 0 0.4 0.4 42 5 34 305 4 0 4 0 -19 0 -18.8 -19 01/24/2005 12:10:00 16.2 1.3 19.5 13.3 16 1.5 19.9 11.8 0.4 0 0.4 0.4 43 5 43 305 4 0 4 0 -18.9 0 -18.6 -19 01/24/2005 12:20:00 15.4 1.3 19.1 12.2 15.1 1.5 19.5 11.8 0.4 0 0.4 0.4 45 5 40 305 4 0 4 0 -19 0 -18.8 -19 01/24/2005 12:30:00 14.9 1.5 19.9 11.8 14.8 1.5 20.6 10.7 0.4 0 0.4 0.4 44 5 40 305 4 0 4 0 -19 0 -18.8 -19 01/24/2005 12:40:00 16.8 1.4 19.9 12.6 16.6 1.3 20.2 12.6 0.4 0 0.4 0.4 45 5 50 305 4 0 4 0 -19 0 -18.8 -19 01/24/2005 12:50:00 14.5 1.3 18.7 11.5 14.4 1.2 17.6 11.5 0.4 0 0.4 0.4 41 5 36 305 4 0 4 0 -19 0 -18.8 -19.2 01/24/2005 13:00:00 16.1 1.3 19.5 12.2 15.9 1.4 19.5 11.1 0.4 0 0.4 0.4 44 5 46 305 4 0 4 0 -19.1 0 -18.8 -19 01/24/2005 13:10:00 16.1 1.2 19.1 13 15.9 1.2 19.1 12.6 0.4 0 0.4 0.4 42 5 42 305 4 0 4 0 -19.1 0 -18.8 -19.2 01/24/2005 13:20:00 16.4 1.4 19.9 13.3 16.1 1.5 20.2 13 0.4 0 0.4 0.4 42 5 41 305 5 0 5 0 -18.9 0 -18.4 -19 01/24/2005 13:30:00 17.1 1.2 19.9 14.1 16.9 1.3 21 13.7 0.4 0 0.4 0.4 45 5 48 305 5 0 5 0 -18.9 0 -18.4 -19 01/24/2005 13:40:00 16.3 1.4 19.5 12.6 16.2 1.5 19.5 12.2 0.4 0 0.4 0.4 42 5 40 305 5 0 5 0 -18.7 0 -18.4 -19 01/24/2005 13:50:00 17.3 1.6 21 14.1 17.2 1.7 21.4 12.6 0.4 0 0.4 0.4 41 5 37 305 5 0 5 0 -18.6 0 -18.2 -18.8 01/24/2005 14:00:00 16.2 1.5 19.9 13 16.1 1.5 20.2 11.5 0.4 0 0.4 0.4 42 5 44 305 5 0 5 0 -18.4 0.1 -18.1 -18.6 01/24/2005 14:10:00 17.2 1.8 21 12.2 17 1.8 21 11.8 0.4 0 0.4 0.4 41 6 48 305 5 0 5 0 -18.3 0 -18.1 -18.4 01/24/2005 14:20:00 16.5 1.7 21.8 12.6 16.3 1.7 21.8 12.6 0.4 0 0.4 0.4 42 6 45 305 5 0 5 0 -18.4 0.1 -18.1 -18.4 01/24/2005 14:30:00 16.8 1.8 21 12.2 16.5 1.8 21.4 11.8 0.4 0 0.4 0.4 43 6 35 305 5 0 5 0 -18.4 0.1 -18.1 -18.4 01/24/2005 14:40:00 18.2 1.2 21.8 14.9 18.1 1.3 21.8 14.9 0.4 0 0.4 0.4 43 4 37 305 5 0 5 0 -18.5 0 -18.1 -18.4 01/24/2005 14:50:00 15.8 1.2 18.3 12.6 15.5 1.2 18.3 12.2 0.4 0 0.4 0.4 43 5 35 305 5 0 5 0 -18.5 0 -18.1 -18.6 01/24/2005 15:00:00 17.7 1.2 20.6 14.1 17.5 1.3 20.2 14.1 0.4 0 0.4 0.4 45 6 46 305 5 0 5 0 -18.6 0 -18.2 -18.6 01/24/2005 15:10:00 18.1 1.6 22.1 14.1 17.9 1.5 21.8 13 0.4 0 0.4 0.4 44 4 48 305 5 0 5 0 -18.5 0 -18.2 -18.6 01/24/2005 15:20:00 18.1 1.7 22.6 14.1 17.8 1.8 23.7 13.7 0.4 0 0.4 0.4 42 5 42 305 5 0 5 0 -18.5 0 -18.2 -18.6 01/24/2005 15:30:00 19 1.8 22.9 14.9 18.8 1.8 22.9 14.5 0.4 0 0.4 0.4 45 6 48 305 5 0 5 0 -18.6 0 -18.2 -18.8 01/24/2005 15:40:00 19 1.4 21.8 14.9 18.5 1.5 21.8 13.7 0.4 0 0.4 0.4 47 5 66 305 5 0 5 0 -18.6 0 -18.4 -18.8 01/24/2005 15:50:00 20.2 1.5 22.9 15.6 20 1.5 23.3 16.1 0.4 0 0.4 0.4 45 4 43 305 5 0 5 0 -18.5 0 -18.2 -18.4 01/24/2005 16:00:00 19.1 1.4 22.1 14.5 18.9 1.5 22.1 13.7 0.4 0 0.4 0.4 44 4 45 305 5 0 5 0 -18.3 0.1 -18.1 -18.4 01/24/2005 16:10:00 18.9 1.6 22.6 14.5 18.7 1.6 21.8 14.5 0.4 0 0.4 0.4 45 5 46 305 5 0 5 0 -18.2 0 -18.1 -18.4 01/24/2005 16:20:00 18.8 1.5 21.4 14.5 18.6 1.5 22.1 14.9 0.4 0 0.4 0.4 41 5 41 305 5 0 5 0 -18.1 0 -17.7 -18.2 01/24/2005 16:30:00 18.5 1.5 22.1 14.1 18.2 1.7 21.8 13.7 0.4 0 0.4 0.4 45 5 44 305 5 0 5 0 -18.1 0 -17.9 -18.4 01/24/2005 16:40:00 18.1 1.5 22.1 14.1 17.9 1.7 22.1 14.1 0.4 0 0.4 0.4 46 4 41 305 5 0 5 0 -18.2 0 -18.1 -18.4 01/24/2005 16:50:00 18.6 1.8 24.4 14.1 18.3 1.9 24.4 13.3 0.4 0 0.4 0.4 46 5 47 305 5 0 5 0 -18.2 0 -18.1 -18.4 01/24/2005 17:00:00 20.2 1.1 22.9 16.8 20 1.3 22.9 16.1 0.4 0 0.4 0.4 45 4 49 305 5 0 5 0 -18.2 0 -18.1 -18.4 01/24/2005 17:10:00 17.8 2.2 21.8 13.3 17.6 2.2 22.1 13 0.4 0 0.4 0.4 43 5 40 305 5 0 5 0 -18.2 0 -18.1 -18.4 01/24/2005 17:20:00 17.8 2 21.4 12.6 17.5 2.1 21.4 12.6 0.4 0 0.4 0.4 48 4 48 305 5 0 5 0 -18.2 0 -18.1 -18.4 01/24/2005 17:30:00 19 1.5 22.1 14.1 18.9 1.6 21.8 13.3 0.4 0 0.4 0.4 47 4 47 305 5 0 5 0 -18.3 0 -18.1 -18.4 01/24/2005 17:40:00 16.6 1.2 19.1 13.3 16.4 1.3 19.1 12.6 0.4 0 0.4 0.4 41 5 47 305 5 0 5 0 -18.3 0 -18.1 -18.4 01/24/2005 17:50:00 17.8 1.3 20.6 13.3 17.7 1.4 21 12.6 0.4 0 0.4 0.4 43 5 40 305 5 0 5 0 -18.3 0.1 -18.1 -18.4 01/24/2005 18:00:00 17.5 1.2 20.2 13.3 17.3 1.2 20.6 13.7 0.4 0 0.4 0.4 43 5 41 305 5 0 5 0 -18.4 0.1 -18.1 -18.4 01/24/2005 18:10:00 17.9 1.3 20.2 14.1 17.7 1.4 20.2 13.7 0.4 0 0.4 0.4 39 4 41 305 5 0 5 0 -18.4 0 -18.1 -18.4 01/24/2005 18:20:00 16.6 1.2 19.9 13 16.3 1.3 18.7 12.2 0.4 0 0.4 0.4 41 5 41 305 5 0 5 0 -18.5 0 -18.1 -18.6 01/24/2005 18:30:00 16.4 1.2 19.5 13.3 16.2 1.3 19.5 13 0.4 0 0.4 0.4 39 5 42 305 5 0 5 0 -18.5 0 -18.2 -18.6 01/24/2005 18:40:00 16.7 1.3 19.1 13.3 16.4 1.5 19.9 12.6 0.4 0 0.4 0.4 36 5 32 305 5 0 5 0 -18.6 0 -18.2 -18.8 01/24/2005 18:50:00 16 1.3 19.5 12.6 16 1.5 19.5 12.2 0.4 0 0.4 0.4 39 4 39 305 5 0 5 0 -18.6 0 -18.2 -18.6 01/24/2005 19:00:00 15.4 1.5 19.1 11.5 15.2 1.6 18.7 10.3 0.4 0 0.4 0.4 39 5 41 305 5 0 5 0 -18.6 0 -18.2 -18.8 01/24/2005 19:10:00 15.9 1.6 19.9 11.8 15.8 1.6 20.2 11.5 0.4 0 0.4 0.4 41 5 41 305 5 0 5 0 -18.5 0 -18.2 -18.6 01/24/2005 19:20:00 15.9 1.3 19.5 13.3 15.6 1.5 19.5 12.6 0.4 0 0.4 0.4 45 6 38 305 5 0 5 0 -18.6 0 -18.2 -18.8 01/24/2005 19:30:00 17.6 1.2 20.2 13.7 17.5 1.3 19.9 13.3 0.4 0 0.4 0.4 44 5 50 305 5 0 5 0 -18.7 0 -18.4 -19 01/24/2005 19:40:00 16.8 1.3 19.5 12.6 16.6 1.3 19.1 13.3 0.4 0 0.4 0.4 46 5 45 305 5 0 5 0 -18.7 0 -18.4 -18.8 01/24/2005 19:50:00 18.2 1.1 20.6 15.3 18.1 1.2 21 14.1 0.4 0 0.4 0.4 42 5 48 305 4 0 5 0 -18.8 0 -18.4 -19 01/24/2005 20:00:00 17 1.4 19.5 13 16.8 1.5 19.5 12.2 0.4 0 0.4 0.4 43 4 43 305 4 0 5 0 -18.8 0 -18.4 -19 01/24/2005 20:10:00 16.9 1.1 19.5 13.3 16.6 1.2 19.1 13 0.4 0 0.4 0.4 44 4 45 305 4 0 4 0 -18.8 0 -18.6 -19 01/24/2005 20:20:00 15.7 1.3 18.7 12.2 15.6 1.4 18.3 11.5 0.4 0 0.4 0.4 41 5 47 305 4 0 5 0 -18.8 0 -18.4 -19 01/24/2005 20:30:00 15.4 1.1 17.9 12.6 15.2 1.3 17.9 11.8 0.4 0 0.4 0.4 46 4 44 305 4 0 5 0 -18.9 0.1 -18.4 -19 01/24/2005 20:40:00 16 1.1 18.3 12.2 15.9 1.1 18.3 12.6 0.4 0 0.4 0.4 43 5 40 305 4 0 4 0 -18.9 0 -18.6 -19 01/24/2005 20:50:00 15.2 1.3 17.9 11.1 15.1 1.5 17.9 11.1 0.4 0 0.4 0.4 39 4 40 305 4 0 4 0 -18.8 0 -18.4 -19 01/24/2005 21:00:00 14.7 0.9 16.8 11.8 14.7 1 16.8 11.5 0.4 0 0.4 0.4 42 4 45 305 4 0 5 0 -18.7 0 -18.4 -19 01/24/2005 21:10:00 15.1 1.1 17.2 12.2 14.9 1.2 17.6 11.5 0.4 0 0.4 0.4 40 5 42 305 5 0 5 0 -18.7 0 -18.4 -18.8 01/24/2005 21:20:00 16.3 1.2 19.1 13 16.2 1.3 19.1 12.2 0.4 0 0.4 0.4 41 4 42 305 5 0 5 0 -18.7 0 -18.4 -18.8 01/24/2005 21:30:00 15.6 1.3 18.3 12.2 15.4 1.4 18.3 11.5 0.4 0 0.4 0.4 42 5 48 305 5 0 5 0 -18.7 0 -18.4 -19 01/24/2005 21:40:00 15.5 1.6 19.5 12.2 15.2 1.7 18.7 11.1 0.4 0 0.4 0.4 44 6 47 305 5 0 5 0 -18.7 0 -18.4 -19 01/24/2005 21:50:00 16.7 1.5 19.9 12.6 16.6 1.6 20.2 12.2 0.4 0 0.4 0.4 44 6 48 305 5 0 5 0 -18.7 0.1 -18.4 -19 01/24/2005 22:00:00 16.6 1.3 19.9 13 16.4 1.4 20.2 12.6 0.4 0 0.4 0.4 46 5 54 305 4 0 5 0 -18.8 0 -18.4 -19 01/24/2005 22:10:00 14.9 1.7 18.7 10.7 14.6 1.8 19.5 10.7 0.4 0 0.4 0.4 45 5 44 305 4 0 5 0 -18.8 0 -18.4 -19 01/24/2005 22:20:00 16.4 1.4 19.5 13 16.1 1.5 19.5 12.2 0.4 0 0.4 0.4 50 5 54 305 4 0 5 0 -18.9 0.1 -18.4 -19 01/24/2005 22:30:00 16 1.4 19.5 12.2 15.7 1.5 19.5 12.2 0.4 0 0.4 0.4 47 6 53 305 4 0 4 0 -19.1 0 -19 -19.3 01/24/2005 22:40:00 16.2 1.3 19.1 12.2 16.1 1.4 19.1 11.8 0.4 0 0.4 0.4 43 4 49 305 4 0 4 0 -19.1 0 -19 -19.2 01/24/2005 22:50:00 16.4 1.3 18.7 12.6 16.2 1.5 19.1 11.5 0.4 0 0.4 0.4 44 4 50 305 4 0 4 0 -19 0 -18.8 -19 01/24/2005 23:00:00 15.2 1.3 18.3 11.5 15.1 1.3 18.7 11.5 0.4 0 0.4 0.4 43 4 43 305 4 0 5 0 -18.9 0.1 -18.6 -19 01/24/2005 23:10:00 15.7 1.1 18.3 12.6 15.7 1.3 18.7 11.8 0.4 0 0.4 0.4 44 4 45 305 4 0 4 0 -18.9 0 -18.8 -19 01/24/2005 23:20:00 15.7 1.5 19.5 11.8 15.6 1.5 19.1 11.1 0.4 0 0.4 0.4 41 5 40 305 4 0 5 0 -18.8 0 -18.4 -19 01/24/2005 23:30:00 16.3 1.1 19.1 13 16.1 1.2 18.7 12.6 0.4 0 0.4 0.4 44 4 50 305 5 0 5 0 -18.7 0.1 -18.4 -19 01/24/2005 23:40:00 15.9 1.3 19.1 12.2 15.8 1.5 19.5 12.2 0.4 0 0.4 0.4 42 5 48 305 5 0 5 0 -18.6 0 -18.4 -18.8 01/24/2005 23:50:00 16.6 1 19.1 13.3 16.4 1.1 18.7 13 0.4 0 0.4 0.4 42 5 38 305 5 0 5 0 -18.6 0 -18.4 -18.8 01/25/2005 00:00:00 17 1.3 20.6 13.7 16.9 1.5 20.2 13.3 0.4 0 0.4 0.4 40 5 45 305 5 0 5 0 -18.6 0 -18.2 -18.8 01/25/2005 00:10:00 17 1.2 20.2 13.7 16.9 1.3 20.6 13 0.4 0 0.4 0.4 42 4 39 305 5 0 5 0 -18.7 0.1 -18.4 -19 01/25/2005 00:20:00 16.7 1.4 19.9 13.3 16.5 1.4 19.9 13.3 0.4 0 0.4 0.4 42 5 29 305 5 0 5 0 -18.8 0 -18.4 -19 01/25/2005 00:30:00 16.8 1.5 19.9 13.7 16.7 1.7 19.9 13 0.4 0 0.4 0.4 42 5 43 305 5 0 5 0 -18.7 0 -18.4 -19 01/25/2005 00:40:00 17.9 1.2 20.2 14.5 17.8 1.3 20.2 14.1 0.4 0 0.4 0.4 43 4 42 305 5 0 5 0 -18.7 0 -18.4 -19 01/25/2005 00:50:00 17 1.2 20.2 13.3 17 1.2 20.2 13.7 0.4 0 0.4 0.4 42 5 48 305 5 0 5 0 -18.7 0 -18.4 -18.8 01/25/2005 01:00:00 17.9 1.7 21 13.3 17.8 1.9 21.8 13 0.4 0 0.4 0.4 41 5 36 305 5 0 5 0 -18.7 0 -18.4 -19 01/25/2005 01:10:00 17.1 1.3 19.9 13 17.1 1.5 19.9 11.8 0.4 0 0.4 0.4 40 5 48 305 5 0 5 0 -18.7 0 -18.4 -19 01/25/2005 01:20:00 17.6 1.3 21 13.3 17.7 1.3 21 14.1 0.4 0 0.4 0.4 42 5 36 305 5 0 5 0 -18.6 0 -18.2 -18.8 01/25/2005 01:30:00 18.1 1.3 21.4 14.5 18.1 1.6 21.8 14.5 0.4 0 0.4 0.4 43 5 37 305 5 0 5 0 -18.5 0 -18.2 -18.4 01/25/2005 01:40:00 16.8 1.2 19.9 13.3 16.8 1.3 20.2 12.6 0.4 0 0.4 0.4 40 6 49 305 5 0 5 0 -18.5 0 -18.1 -18.4 01/25/2005 01:50:00 17.9 1.2 20.6 14.1 18 1.3 22.1 14.9 0.4 0 0.4 0.4 40 5 38 305 5 0 5 0 -18.4 0.1 -18.1 -18.4 01/25/2005 02:00:00 17.6 1.7 21 12.6 17.5 1.8 21 12.6 0.4 0 0.4 0.4 38 5 35 305 5 0 5 0 -18.4 0.1 -18.1 -18.4 01/25/2005 02:10:00 17.2 1.3 20.6 13.3 17.2 1.4 21 13.3 0.4 0 0.4 0.4 38 5 41 305 5 0 5 0 -18.5 0 -18.2 -18.6 01/25/2005 02:20:00 17.6 1.2 20.2 14.1 17.6 1.3 20.2 13.3 0.4 0 0.4 0.4 35 4 36 305 5 0 5 0 -18.6 0 -18.2 -18.6 01/25/2005 02:30:00 16.9 1.7 20.6 13 16.8 1.8 20.6 13 0.4 0 0.4 0.4 36 5 33 305 5 0 5 0 -18.4 0.1 -18.1 -18.4 01/25/2005 02:40:00 16.9 1.4 20.2 13.3 16.8 1.5 19.9 13.3 0.4 0 0.4 0.4 41 6 35 305 5 0 5 0 -18.3 0 -18.1 -18.4 01/25/2005 02:50:00 17.3 1.5 20.6 13 17.3 1.6 21 13.3 0.4 0 0.4 0.4 42 6 39 305 5 0 5 0 -18.2 0 -17.9 -18.4 01/25/2005 03:00:00 16.8 1.3 19.9 13 16.9 1.3 20.2 13 0.4 0 0.4 0.4 39 5 39 305 5 0 5 0 -18.1 0 -17.9 -18.2 01/25/2005 03:10:00 17.6 1.5 21.8 13.3 17.6 1.6 22.1 12.6 0.4 0 0.4 0.4 40 5 40 305 5 0 5 0 -18.1 0 -18.1 -18.2 01/25/2005 03:20:00 16.4 1.3 19.9 12.6 16.5 1.4 20.6 13.3 0.4 0 0.4 0.4 40 5 42 305 5 0 5 0 -18.1 0 -18.1 -18.2 01/25/2005 03:30:00 16.6 1.3 19.5 11.8 16.7 1.3 19.9 12.6 0.4 0 0.4 0.4 39 5 37 305 5 0 5 0 -18.1 0 -18.1 -18.2 01/25/2005 03:40:00 16.2 1.6 19.5 10.7 16.2 1.7 19.9 11.5 0.4 0 0.4 0.4 38 6 41 305 5 0 5 0 -18.1 0.1 -18.1 -18.4 01/25/2005 03:50:00 17.1 1.8 21.4 12.6 17.1 1.8 21 13.3 0.4 0 0.4 0.4 38 5 45 305 5 0 5 0 -18.4 0 -18.1 -18.4 01/25/2005 04:00:00 16.5 1.6 20.2 12.6 16.5 1.7 20.6 12.6 0.4 0 0.4 0.4 37 6 38 305 5 0 5 0 -18.3 0.1 -18.1 -18.4 01/25/2005 04:10:00 17.8 1.5 20.6 13.7 17.8 1.7 21.4 12.2 0.4 0 0.4 0.4 37 4 35 305 5 0 5 0 -18.3 0 -18.1 -18.4 01/25/2005 04:20:00 16.4 1.7 20.2 12.2 16.4 1.8 20.6 11.5 0.4 0 0.4 0.4 37 6 39 305 5 0 5 0 -18.2 0 -18.1 -18.4 01/25/2005 04:30:00 16.7 1.5 19.9 13 16.7 1.6 20.2 12.6 0.4 0 0.4 0.4 40 5 38 305 5 0 5 0 -18.2 0 -18.1 -18.4 01/25/2005 04:40:00 16.9 1.5 19.9 13 16.8 1.6 20.6 12.6 0.4 0 0.4 0.4 39 5 51 305 5 0 5 0 -18.1 0 -17.9 -18.4 01/25/2005 04:50:00 17.3 1.2 20.2 14.5 17.1 1.3 21.4 14.1 0.4 0 0.4 0.4 42 5 40 305 5 0 5 0 -18.1 0 -18.1 -18.2 01/25/2005 05:00:00 17.4 1.5 21 12.2 17.4 1.6 21.4 12.6 0.4 0 0.4 0.4 38 6 36 305 5 0 5 0 -18.1 0 -17.7 -18.2 01/25/2005 05:10:00 19.1 1.6 23.3 15.3 19 1.7 23.3 14.5 0.4 0 0.4 0.4 36 5 32 305 5 0 5 0 -18 0 -17.7 -18.2 01/25/2005 05:20:00 19.5 1.8 23.7 14.1 19.4 1.9 24.4 13.7 0.4 0 0.4 0.4 36 5 36 305 5 0 5 0 -18 0 -17.7 -18.1 01/25/2005 05:30:00 17.2 1.7 20.6 12.6 17.1 1.7 21 12.6 0.4 0 0.4 0.4 39 6 41 305 5 0 5 0 -17.9 0.1 -17.5 -18.1 01/25/2005 05:40:00 17.5 1.7 21.8 13 17.3 1.7 21.8 13 0.4 0 0.4 0.4 40 5 40 305 5 0 5 0 -17.9 0 -17.5 -18.1 01/25/2005 05:50:00 16.9 1.3 19.9 13 16.8 1.3 19.9 13.3 0.4 0 0.4 0.4 41 5 34 305 5 0 5 0 -17.9 0 -17.5 -18.1 01/25/2005 06:00:00 17 1.2 19.5 13.3 16.8 1.3 19.9 13 0.4 0 0.4 0.4 40 5 33 305 5 0 5 0 -17.9 0.1 -17.5 -18.1 01/25/2005 06:10:00 17.9 2.1 23.7 12.2 17.7 2.2 24 11.5 0.4 0 0.4 0.4 42 5 39 305 5 0 5 0 -17.8 0.1 -17.5 -18.1 01/25/2005 06:20:00 17.8 1.3 21.4 14.1 17.5 1.5 21.4 14.5 0.4 0 0.4 0.4 42 6 39 305 5 0 5 0 -17.7 0 -17.5 -17.9 01/25/2005 06:30:00 18.3 1.7 22.9 14.1 18.2 1.7 23.7 14.1 0.4 0 0.4 0.4 42 5 41 305 5 0 5 0 -17.7 0 -17.5 -17.9 01/25/2005 06:40:00 18.2 1.7 21.4 14.1 18.1 1.7 21.8 13.3 0.4 0 0.4 0.4 42 5 45 305 5 0 5 0 -17.6 0.1 -17.3 -17.9 01/25/2005 06:50:00 17.5 1.5 21.8 12.6 17.4 1.6 22.9 13.7 0.4 0 0.4 0.4 42 5 38 305 5 0 5 0 -17.4 0 -16.9 -17.5 01/25/2005 07:00:00 17 1.4 19.9 13 16.8 1.4 19.9 12.6 0.4 0 0.4 0.4 41 5 44 305 6 0 6 0 -17.3 0 -16.9 -17.5 01/25/2005 07:10:00 16.2 1.7 20.6 12.2 16.1 1.7 20.2 12.2 0.4 0 0.4 0.4 39 6 39 305 6 0 6 0 -17.2 0 -16.9 -17.3 01/25/2005 07:20:00 17.7 1.7 21.8 13.7 17.5 1.8 21.8 13.3 0.4 0 0.4 0.4 39 5 40 305 6 0 6 0 -17.1 0 -16.9 -17.1 01/25/2005 07:30:00 15.9 2.1 20.2 10.7 15.7 2.1 20.2 10.7 0.4 0 0.4 0.4 37 5 38 305 6 0 6 0 -17 0 -16.9 -17.1 01/25/2005 07:40:00 17.4 1.8 20.6 12.6 17.3 1.9 21 12.2 0.4 0 0.4 0.4 37 5 35 305 6 0 6 0 -17.1 0 -16.9 -17.3 01/25/2005 07:50:00 15.8 1.5 19.1 12.2 15.5 1.5 18.7 11.8 0.4 0 0.4 0.4 37 5 37 305 6 0 6 0 -17 0 -16.9 -17.1 01/25/2005 08:00:00 15.1 1.4 18.7 11.8 15 1.3 18.7 11.8 0.4 0 0.4 0.4 39 5 37 305 6 0 6 0 -16.9 0 -16.6 -16.9 01/25/2005 08:10:00 15.5 1.4 18.3 11.8 15.4 1.5 18.3 11.1 0.4 0 0.4 0.4 41 5 39 305 6 0 6 0 -16.9 0 -16.6 -16.9 01/25/2005 08:20:00 15.7 1.3 18.7 11.8 15.6 1.4 18.3 11.5 0.4 0 0.4 0.4 36 4 30 305 6 0 6 0 -16.7 0 -16.4 -16.9 01/25/2005 08:30:00 14.6 1.3 17.9 11.5 14.5 1.3 17.9 11.1 0.4 0 0.4 0.4 34 5 26 305 6 0 6 0 -16.5 0 -16.4 -16.7 01/25/2005 08:40:00 16.5 1.5 20.2 12.6 16.3 1.5 20.6 12.2 0.4 0 0.4 0.4 37 5 40 305 6 0 6 0 -16.4 0 -16 -16.6 01/25/2005 08:50:00 17.7 1.2 20.6 14.5 17.6 1.3 20.6 14.1 0.4 0 0.4 0.4 38 5 41 305 6 0 7 0 -16.4 0 -16.2 -16.6 01/25/2005 09:00:00 18.6 1.2 21.4 15.3 18.3 1.2 21 14.9 0.4 0 0.4 0.4 33 4 37 305 6 0 6 0 -16.4 0 -16 -16.6 01/25/2005 09:10:00 17 1.2 19.9 13.7 16.8 1.3 19.9 13.3 0.4 0 0.4 0.4 36 5 33 305 6 0 6 0 -16.4 0 -16 -16.6 01/25/2005 09:20:00 15.7 1.5 20.2 12.2 15.7 1.6 20.6 12.2 0.4 0 0.4 0.4 36 5 30 305 7 0 7 0 -16.3 0.1 -15.8 -16.4 01/25/2005 09:30:00 17 1.7 21 13 16.7 1.7 21 12.6 0.4 0 0.4 0.4 35 5 28 305 7 0 7 0 -16.3 0 -15.8 -16.4 01/25/2005 09:40:00 16.1 1.5 20.6 12.2 15.9 1.5 19.5 12.2 0.4 0 0.4 0.4 40 6 47 305 7 0 7 0 -16.1 0.1 -15.6 -16.4 01/25/2005 09:50:00 15.8 1.7 20.2 12.2 15.6 1.7 20.2 11.8 0.4 0 0.4 0.4 41 5 31 305 7 0 7 0 -15.9 0 -15.6 -16 01/25/2005 10:00:00 16.9 2 21.8 12.2 16.6 2 21.8 12.2 0.4 0 0.4 0.4 39 5 41 305 7 0 7 0 -15.9 0 -15.6 -16.2 01/25/2005 10:10:00 17.9 1.7 22.6 14.1 17.8 1.7 22.9 13 0.4 0 0.4 0.4 43 5 40 305 7 0 7 0 -15.9 0.1 -15.6 -16.2 01/25/2005 10:20:00 16.4 1.9 20.6 12.2 16.1 1.9 20.6 11.5 0.4 0 0.4 0.4 44 5 48 305 7 0 7 0 -15.8 0.1 -15.2 -16 01/25/2005 10:30:00 15.4 1.7 20.6 10.7 15.2 1.7 19.9 9.9 0.4 0 0.4 0.4 43 6 46 305 7 0 7 0 -15.6 0 -15 -15.6 01/25/2005 10:40:00 16.4 1.8 20.6 11.1 16.2 1.8 20.6 11.5 0.4 0 0.4 0.4 41 5 39 305 8 0 7 0 -15.5 0.1 -15 -15.6 01/25/2005 10:50:00 16.2 1.3 20.6 13 16.2 1.4 20.2 11.8 0.4 0 0.4 0.4 43 5 40 305 7 0 7 0 -15.6 0.1 -15 -15.8 01/25/2005 11:00:00 16.1 1.2 19.9 13 16 1.3 19.5 12.2 0.4 0 0.4 0.4 43 4 41 305 7 0 8 0 -15.7 0.1 -15.2 -15.8 01/25/2005 11:10:00 14.6 1.5 17.9 10.7 14.5 1.6 17.9 9.9 0.4 0 0.4 0.4 40 4 38 305 7 0 7 0 -15.6 0.1 -15 -15.8 01/25/2005 11:20:00 14.8 1.5 18.7 11.1 14.7 1.5 18.3 11.1 0.4 0 0.4 0.4 38 5 45 305 8 0 8 0 -15.5 0 -15 -15.6 01/25/2005 11:30:00 14.8 1.2 17.9 12.2 14.7 1.3 18.7 11.8 0.4 0 0.4 0.4 39 4 39 305 8 0 7 0 -15.5 0 -15 -15.6 01/25/2005 11:40:00 13.9 1.2 17.6 10.3 13.7 1.2 17.2 10.3 0.4 0 0.4 0.4 38 6 37 305 8 0 8 0 -15.3 0 -15 -15.6 01/25/2005 11:50:00 13.8 1.5 17.2 9.9 13.8 1.5 17.2 10.3 0.4 0 0.4 0.4 39 5 42 305 8 0 8 0 -15.2 0 -14.6 -15.4 01/25/2005 12:00:00 13.8 1.7 18.3 9.5 13.7 1.7 18.3 10.3 0.4 0 0.4 0.4 40 5 39 305 8 0 8 0 -15.1 0 -14.6 -15.2 01/25/2005 12:10:00 12.9 1.2 15.6 9.5 12.8 1.2 15.6 8.8 0.4 0 0.4 0.4 39 5 41 305 8 0 8 0 -15.1 0 -14.8 -15.2 01/25/2005 12:20:00 14.1 1.6 17.6 9.5 14 1.6 17.9 9.1 0.4 0 0.4 0.4 37 6 36 305 8 0 8 0 -15 0 -14.6 -15 01/25/2005 12:30:00 13.8 1.5 17.9 11.1 13.7 1.5 18.3 10.7 0.4 0 0.4 0.4 43 5 43 305 8 0 8 0 -14.8 0 -14.6 -15 01/25/2005 12:40:00 13.6 1.3 17.9 10.3 13.6 1.3 17.2 9.9 0.4 0 0.4 0.4 43 6 46 305 8 0 8 0 -14.8 0 -14.6 -15 01/25/2005 12:50:00 13.4 1.2 16.4 10.3 13.3 1.3 16.8 10.3 0.4 0 0.4 0.4 38 5 40 305 8 0 8 0 -14.8 0 -14.6 -15 01/25/2005 13:00:00 13.2 1 16.4 10.7 13.2 1.1 16.1 10.7 0.4 0 0.4 0.4 41 5 46 305 9 0 8 0 -14.7 0 -14.3 -14.8 01/25/2005 13:10:00 13.7 1 16.8 10.7 13.6 1.1 16.4 10.3 0.4 0 0.4 0.4 42 5 43 305 9 0 9 0 -14.7 0 -14.3 -14.8 01/25/2005 13:20:00 13.7 0.8 15.6 11.5 13.5 0.9 16.4 11.1 0.4 0 0.4 0.4 43 5 42 305 9 0 9 0 -14.6 0 -14.4 -14.6 01/25/2005 13:30:00 13.9 1.2 17.6 11.1 13.8 1.2 17.6 10.7 0.4 0 0.4 0.4 43 5 46 305 9 0 9 0 -14.5 0 -14.3 -14.6 01/25/2005 13:40:00 13.5 1.3 17.2 9.1 13.3 1.3 16.8 9.9 0.4 0 0.4 0.4 46 5 45 305 9 0 9 0 -14.4 0.1 -14.1 -14.6 01/25/2005 13:50:00 14.3 1 16.8 11.5 14.2 1.1 16.8 11.1 0.4 0 0.4 0.4 45 5 41 305 9 0 9 0 -14.3 0 -13.9 -14.4 01/25/2005 14:00:00 14.4 1 17.6 12.2 14.2 1.1 16.8 12.2 0.4 0 0.4 0.4 46 5 50 305 10 0 9 0 -14.3 0 -13.9 -14.4 01/25/2005 14:10:00 14.3 1.4 17.9 11.5 14.3 1.5 17.6 11.1 0.4 0 0.4 0.4 44 6 46 305 9 0 9 0 -14.3 0.1 -13.9 -14.4 01/25/2005 14:20:00 13.7 1.2 16.8 9.9 13.7 1.3 17.9 10.3 0.4 0 0.4 0.4 45 6 53 305 9 0 9 0 -14.4 0.1 -13.9 -14.6 01/25/2005 14:30:00 15 1.3 18.7 11.8 15.1 1.3 18.3 12.2 0.4 0 0.4 0.4 43 6 41 305 9 0 9 0 -14.4 0 -14.1 -14.6 01/25/2005 14:40:00 16 1.2 19.5 12.2 16 1.3 19.5 12.6 0.4 0 0.4 0.4 44 6 44 305 9 0 9 0 -14.4 0.1 -14.1 -14.6 01/25/2005 14:50:00 13.7 1.1 16.8 11.1 13.6 1.2 17.2 11.5 0.4 0 0.4 0.4 50 5 50 305 9 0 9 0 -14.5 0.1 -14.3 -14.6 01/25/2005 15:00:00 13.9 1.1 16.8 11.1 13.8 1.1 16.4 10.7 0.4 0 0.4 0.4 49 5 44 305 9 0 9 0 -14.4 0 -14.3 -14.6 01/25/2005 15:10:00 14.9 1 18.3 13 14.9 1.1 18.3 12.6 0.4 0 0.4 0.4 47 6 53 305 9 0 9 0 -14.4 0.1 -14.1 -14.6 01/25/2005 15:20:00 15 1.3 18.3 12.2 14.9 1.3 17.9 11.5 0.4 0 0.4 0.4 47 5 41 305 9 0 9 0 -14.4 0 -13.9 -14.4 01/25/2005 15:30:00 15.8 1.5 19.1 12.2 15.7 1.6 19.1 11.8 0.4 0 0.4 0.4 47 5 45 305 10 0 9 0 -14.2 0 -13.7 -14.4 01/25/2005 15:40:00 15.3 1.1 19.1 12.2 15.2 1.1 18.7 12.2 0.4 0 0.4 0.4 46 4 49 305 10 0 10 0 -14.1 0.1 -13.7 -14.3 01/25/2005 15:50:00 15.1 1.1 18.7 11.8 14.9 1.1 18.7 12.2 0.4 0 0.4 0.4 44 5 45 305 10 0 10 0 -14.1 0.1 -13.7 -14.3 01/25/2005 16:00:00 15.5 1.2 19.5 11.8 15.3 1.2 19.1 12.6 0.4 0 0.4 0.4 46 5 48 305 10 0 10 0 -14 0 -13.7 -14.3 01/25/2005 16:10:00 15.4 1.1 17.9 13 15.4 1 18.3 13.3 0.4 0 0.4 0.4 48 5 50 305 10 0 10 0 -14 0 -13.7 -14.3 01/25/2005 16:20:00 13.8 1.1 16.4 11.1 13.8 1.1 16.4 11.1 0.4 0 0.4 0.4 50 5 53 305 10 0 10 0 -14 0 -13.7 -14.3 01/25/2005 16:30:00 12.8 1.2 16.1 10.3 12.8 1.1 16.1 9.9 0.4 0 0.4 0.4 46 7 49 305 10 0 10 0 -13.9 0 -13.7 -14.3 01/25/2005 16:40:00 12.3 1.7 16.1 8.8 12.3 1.7 16.1 8.8 0.4 0 0.4 0.4 41 6 35 305 10 0 10 0 -13.9 0 -13.7 -14.1 01/25/2005 16:50:00 11.8 1.4 16.4 8.4 11.7 1.3 15.3 8.8 0.4 0 0.4 0.4 44 7 50 305 10 0 10 0 -13.8 0 -13.7 -14.1 01/25/2005 17:00:00 13.5 1.4 16.8 9.1 13.4 1.4 16.8 9.1 0.4 0 0.4 0.4 44 5 51 305 10 0 10 0 -13.9 0 -13.5 -14.1 01/25/2005 17:10:00 13.2 1.2 16.1 10.7 13.2 1.3 16.1 10.7 0.4 0 0.4 0.4 45 5 46 305 10 0 10 0 -13.9 0 -13.5 -14.1 01/25/2005 17:20:00 13.2 1.4 17.9 10.3 13.2 1.5 17.6 9.9 0.4 0 0.4 0.4 42 6 42 305 10 0 10 0 -13.9 0 -13.7 -14.1 01/25/2005 17:30:00 13 1.1 16.4 10.7 13 1.2 16.4 10.3 0.4 0 0.4 0.4 43 5 46 305 10 0 10 0 -14 0 -13.7 -14.3 01/25/2005 17:40:00 13.1 1.3 16.1 9.5 13.1 1.3 16.4 9.5 0.4 0 0.4 0.4 41 5 44 305 10 0 10 0 -13.9 0 -13.7 -14.1 01/25/2005 17:50:00 13.2 1.4 17.6 9.5 13.1 1.3 16.4 9.1 0.4 0 0.4 0.4 44 5 45 305 10 0 10 0 -13.8 0 -13.3 -13.9 01/25/2005 18:00:00 12.2 1 14.9 9.5 12.1 1 15.6 9.1 0.4 0 0.4 0.4 44 5 47 305 10 0 10 0 -13.7 0 -13.3 -13.9 01/25/2005 18:10:00 12.9 1 15.6 10.3 12.7 1 15.3 10.3 0.4 0 0.4 0.4 48 5 43 305 10 0 10 0 -13.8 0 -13.5 -13.9 01/25/2005 18:20:00 13.1 1 15.6 10.3 13 1 15.6 9.9 0.4 0 0.4 0.4 50 5 57 305 10 0 10 0 -13.8 0 -13.3 -13.9 01/25/2005 18:30:00 13.3 1.1 16.4 11.1 13.2 1.1 16.4 10.3 0.4 0 0.4 0.4 51 5 52 305 10 0 10 0 -13.8 0 -13.3 -13.9 01/25/2005 18:40:00 12.8 1.2 15.3 10.3 12.8 1.2 15.6 9.9 0.4 0 0.4 0.4 48 5 50 305 10 0 10 0 -13.8 0 -13.3 -13.9 01/25/2005 18:50:00 14 1.5 17.9 10.7 14 1.5 18.3 10.7 0.4 0 0.4 0.4 47 4 42 305 10 0 10 0 -13.9 0 -13.5 -14.1 01/25/2005 19:00:00 13 1 15.6 10.7 13 1 14.9 10.7 0.4 0 0.4 0.4 45 5 53 305 10 0 10 0 -13.9 0.1 -13.5 -14.1 01/25/2005 19:10:00 13 1.1 15.6 10.7 12.8 1.1 15.3 10.3 0.4 0 0.4 0.4 42 5 44 305 10 0 10 0 -13.9 0.1 -13.5 -14.1 01/25/2005 19:20:00 13.6 1.1 16.8 11.1 13.5 1.1 17.2 11.1 0.4 0 0.4 0.4 43 5 44 305 10 0 10 0 -14.1 0.1 -13.7 -14.3 01/25/2005 19:30:00 14.4 0.9 16.4 12.2 14.4 1 16.4 11.8 0.4 0 0.4 0.4 45 4 51 305 10 0 10 0 -14.2 0 -13.7 -14.3 01/25/2005 19:40:00 14 0.9 16.1 12.2 13.9 0.9 16.4 11.8 0.4 0 0.4 0.4 40 4 41 305 10 0 10 0 -14.2 0 -13.7 -14.3 01/25/2005 19:50:00 14.6 1.1 16.8 12.2 14.5 1.1 17.2 12.2 0.4 0 0.4 0.4 41 3 39 305 10 0 10 0 -14.1 0 -13.7 -14.3 01/25/2005 20:00:00 14.1 1 16.8 11.8 14 1 16.4 11.5 0.4 0 0.4 0.4 41 3 39 305 10 0 10 0 -14.1 0 -13.7 -14.3 01/25/2005 20:10:00 13.4 0.6 14.9 12.2 13.5 0.7 14.9 11.1 0.4 0 0.4 0.4 40 3 50 305 10 0 10 0 -14.1 0.1 -13.7 -14.3 01/25/2005 20:20:00 13.4 0.8 15.3 11.1 13.3 0.8 14.9 11.1 0.4 0 0.4 0.4 38 4 36 305 10 0 10 0 -13.9 0 -13.5 -14.3 01/25/2005 20:30:00 14.1 0.7 15.6 11.8 13.9 0.8 15.6 11.5 0.4 0 0.4 0.4 36 3 36 305 10 0 10 0 -13.9 0 -13.5 -14.1 01/25/2005 20:40:00 13.4 0.7 15.6 11.5 13.4 0.7 15.3 11.1 0.4 0 0.4 0.4 36 4 35 305 10 0 10 0 -13.8 0 -13.3 -14.1 01/25/2005 20:50:00 13.7 0.8 15.6 11.1 13.6 0.9 15.6 11.5 0.4 0 0.4 0.4 40 5 35 305 11 0 11 0 -13.6 0 -13.1 -13.7 01/25/2005 21:00:00 13.4 1.1 16.1 10.3 13.2 1.2 16.1 9.9 0.4 0 0.4 0.4 39 6 35 305 11 0 11 0 -13.6 0 -13.3 -13.7 01/25/2005 21:10:00 13.7 0.9 15.6 11.1 13.5 1 16.1 11.1 0.4 0 0.4 0.4 45 5 40 305 11 0 11 0 -13.6 0 -13.3 -13.7 01/25/2005 21:20:00 14.1 1.3 17.2 10.7 14 1.3 17.2 10.7 0.4 0 0.4 0.4 42 5 40 305 11 0 11 0 -13.6 0 -13.3 -13.7 01/25/2005 21:30:00 13.8 1 16.1 9.9 13.8 1.1 16.4 9.9 0.4 0 0.4 0.4 40 4 39 305 11 0 11 0 -13.6 0 -13.3 -13.7 01/25/2005 21:40:00 12.7 1 15.6 10.3 12.6 1.1 15.6 10.3 0.4 0 0.4 0.4 43 6 38 305 11 0 11 0 -13.7 0 -13.5 -13.7 01/25/2005 21:50:00 12.8 0.9 14.9 9.9 12.8 1 15.3 8.8 0.4 0 0.4 0.4 53 5 58 305 11 0 11 0 -13.6 0 -13.3 -13.7 01/25/2005 22:00:00 13.9 1 17.2 11.5 13.8 1.1 17.2 11.1 0.4 0 0.4 0.4 46 5 38 305 11 0 11 0 -13.6 0 -13.5 -13.7 01/25/2005 22:10:00 13 0.8 14.9 11.1 13 0.9 15.3 10.7 0.4 0 0.4 0.4 44 5 48 305 11 0 11 0 -13.7 0 -13.5 -13.7 01/25/2005 22:20:00 14 0.8 16.1 12.2 14.1 0.8 16.1 12.2 0.4 0 0.4 0.4 42 4 39 305 11 0 11 0 -13.7 0 -13.7 -13.9 01/25/2005 22:30:00 13.7 1 15.6 11.5 13.7 1.1 16.1 11.1 0.4 0 0.4 0.4 42 4 38 305 11 0 11 0 -13.8 0 -13.7 -13.9 01/25/2005 22:40:00 13.7 0.8 15.3 11.8 13.8 0.8 15.6 11.5 0.4 0 0.4 0.4 41 4 41 305 10 0 11 0 -13.8 0 -13.3 -13.9 01/25/2005 22:50:00 13.4 1.1 16.1 10.3 13.4 1.1 15.6 10.7 0.4 0 0.4 0.4 42 4 48 305 11 0 11 0 -13.7 0 -13.3 -13.9 01/25/2005 23:00:00 13.4 0.8 15.3 11.1 13.4 0.9 16.1 11.1 0.4 0 0.4 0.4 42 4 45 305 11 0 11 0 -13.7 0 -13.3 -13.9 01/25/2005 23:10:00 13.4 0.9 15.3 10.7 13.4 1 15.6 10.7 0.4 0 0.4 0.4 39 4 39 305 11 0 11 0 -13.7 0 -13.3 -13.9 01/25/2005 23:20:00 14.2 0.8 16.4 11.8 14.1 0.9 16.1 11.1 0.4 0 0.4 0.4 38 4 47 305 10 0 10 0 -13.8 0 -13.3 -14.1 01/25/2005 23:30:00 14.7 0.8 16.8 12.6 14.8 0.9 17.2 12.6 0.4 0 0.4 0.4 41 4 48 305 11 0 11 0 -13.7 0 -13.3 -13.9 01/25/2005 23:40:00 14.4 1.2 16.8 11.5 14.3 1.2 17.2 11.1 0.4 0 0.4 0.4 43 4 45 305 11 0 11 0 -13.7 0 -13.3 -13.7 01/25/2005 23:50:00 12.8 1.2 16.1 10.7 12.7 1.2 16.4 10.3 0.4 0 0.4 0.4 42 5 38 305 11 0 11 0 -13.7 0 -13.3 -13.7 01/26/2005 00:00:00 14.2 1.2 17.6 11.1 14.2 1.3 17.6 11.1 0.4 0 0.4 0.4 43 5 46 305 11 0 11 0 -13.7 0 -13.3 -13.7 01/26/2005 00:10:00 14.7 1.2 17.2 11.8 14.7 1.3 17.2 11.8 0.4 0 0.4 0.4 43 4 37 305 11 0 11 0 -13.7 0 -13.3 -13.9 01/26/2005 00:20:00 13.9 1.2 17.2 11.8 13.8 1.2 17.2 11.5 0.4 0 0.4 0.4 43 4 41 305 11 0 11 0 -13.6 0 -13.3 -13.7 01/26/2005 00:30:00 14.3 0.7 16.4 12.6 14.4 0.8 16.1 12.2 0.4 0 0.4 0.4 43 4 47 305 11 0 11 0 -13.6 0 -13.3 -13.7 01/26/2005 00:40:00 13.8 1 16.1 11.8 13.8 1 16.4 11.5 0.4 0 0.4 0.4 44 5 47 305 11 0 11 0 -13.6 0 -13.3 -13.7 01/26/2005 00:50:00 13.1 1 16.4 10.7 13.1 1 16.1 11.1 0.4 0 0.4 0.4 43 5 40 305 11 0 11 0 -13.6 0.1 -13.1 -13.7 01/26/2005 01:00:00 14.4 1.1 16.4 11.5 14.3 1 16.8 11.8 0.4 0 0.4 0.4 45 5 42 305 11 0 11 0 -13.6 0.1 -13.1 -13.7 01/26/2005 01:10:00 14 1.3 16.8 11.1 13.8 1.3 16.4 10.3 0.4 0 0.4 0.4 44 5 49 305 11 0 11 0 -13.4 0.1 -13.1 -13.7 01/26/2005 01:20:00 13.3 1 16.8 10.3 13.2 1 16.1 10.7 0.4 0 0.4 0.4 43 5 30 305 11 0 11 0 -13.3 0.1 -12.9 -13.5 01/26/2005 01:30:00 14.3 1.2 17.6 11.1 14.2 1.3 17.6 10.7 0.4 0 0.4 0.4 42 5 47 305 11 0 11 0 -13.4 0.1 -12.9 -13.7 01/26/2005 01:40:00 13.8 0.9 16.4 11.8 13.7 1 16.8 11.5 0.4 0 0.4 0.4 46 4 39 305 11 0 11 0 -13.4 0.1 -13.1 -13.7 01/26/2005 01:50:00 14.6 1.1 17.2 11.8 14.6 1.2 17.2 11.5 0.4 0 0.4 0.4 49 5 43 305 11 0 11 0 -13.4 0.1 -12.9 -13.7 01/26/2005 02:00:00 14.3 1 17.2 11.1 14.1 1.1 17.6 11.5 0.4 0 0.4 0.4 46 5 52 305 11 0 11 0 -13.3 0.1 -12.9 -13.5 01/26/2005 02:10:00 14.7 1.2 17.9 11.8 14.6 1.2 17.6 11.1 0.4 0 0.4 0.4 46 5 49 305 11 0 11 0 -13.2 0.1 -12.9 -13.3 01/26/2005 02:20:00 15.7 0.9 17.9 13 15.6 1 18.7 13 0.4 0 0.4 0.4 49 4 48 305 11 0 11 0 -13.2 0 -12.9 -13.5 01/26/2005 02:30:00 15.1 1 19.5 12.6 14.9 1.1 17.9 11.5 0.4 0 0.4 0.4 47 4 45 305 11 0 12 0 -13.1 0 -12.9 -13.3 01/26/2005 02:40:00 16.2 1.1 18.7 13.7 16 1.1 19.1 12.6 0.4 0 0.4 0.4 46 5 43 305 11 0 12 0 -13.1 0 -12.9 -13.3 01/26/2005 02:50:00 16.2 0.8 18.7 14.1 16.1 0.9 19.1 13.3 0.4 0 0.4 0.4 48 3 46 305 11 0 11 0 -13.3 0 -12.9 -13.5 01/26/2005 03:00:00 15.7 1.1 17.9 13.3 15.5 1.2 18.3 13 0.4 0 0.4 0.4 46 3 52 305 11 0 11 0 -13.2 0 -12.9 -13.3 01/26/2005 03:10:00 16.4 1.1 19.1 12.6 16.1 1.2 18.7 11.8 0.4 0 0.4 0.4 48 5 45 305 11 0 12 0 -13.2 0 -12.9 -13.3 01/26/2005 03:20:00 15.7 0.9 18.3 13.3 15.6 1 18.3 12.6 0.4 0 0.4 0.4 49 4 43 305 12 0 12 0 -13.1 0 -12.7 -13.3 01/26/2005 03:30:00 16.1 0.8 17.9 14.1 16.1 0.8 17.9 13.7 0.4 0 0.4 0.4 50 3 51 305 12 0 12 0 -13.1 0 -12.7 -13.3 01/26/2005 03:40:00 15.7 1.1 19.1 13 15.6 1.1 19.5 13 0.4 0 0.4 0.4 51 4 48 305 12 0 12 0 -13.1 0 -12.7 -13.3 01/26/2005 03:50:00 15.6 1.3 19.1 12.6 15.5 1.3 19.1 11.8 0.4 0 0.4 0.4 46 5 41 305 12 0 12 0 -13.1 0 -12.7 -13.3 01/26/2005 04:00:00 16 1 18.3 13 15.8 1.1 18.7 12.6 0.4 0 0.4 0.4 47 5 43 305 12 0 12 0 -13.1 0 -12.9 -13.3 01/26/2005 04:10:00 15.4 0.9 17.9 13 15.3 1 17.9 12.6 0.4 0 0.4 0.4 46 4 50 305 12 0 12 0 -13.1 0 -12.7 -13.3 01/26/2005 04:20:00 15.9 0.9 18.7 13.3 15.8 0.9 18.3 13.3 0.4 0 0.4 0.4 43 4 42 305 12 0 12 0 -13.1 0 -12.5 -13.3 01/26/2005 04:30:00 16.3 0.7 18.3 14.1 16.1 0.9 17.9 13.7 0.4 0 0.4 0.4 46 4 43 305 12 0 12 0 -13.2 0 -12.9 -13.3 01/26/2005 04:40:00 15.9 0.8 19.1 13.7 15.8 0.9 18.3 13.3 0.4 0 0.4 0.4 48 4 57 305 12 0 12 0 -13.1 0 -12.7 -13.3 01/26/2005 04:50:00 16.9 1.1 19.9 14.1 16.8 1.1 19.5 13.7 0.4 0 0.4 0.4 47 4 45 305 12 0 12 0 -13.1 0 -12.9 -13.3 01/26/2005 05:00:00 17.7 0.9 19.9 14.9 17.5 1 20.2 14.9 0.4 0 0.4 0.4 48 3 53 305 12 0 12 0 -13.1 0 -12.9 -13.3 01/26/2005 05:10:00 17.4 1 19.9 14.5 17.3 1.1 19.5 14.5 0.4 0 0.4 0.4 46 4 42 305 12 0 12 0 -13.1 0 -12.9 -13.3 01/26/2005 05:20:00 15.8 0.9 18.3 13.3 15.7 1 18.3 13.3 0.4 0 0.4 0.4 46 4 45 305 12 0 12 0 -13.1 0 -12.9 -13.3 01/26/2005 05:30:00 17 0.8 19.1 14.1 16.9 0.9 19.1 14.1 0.4 0 0.4 0.4 45 3 41 305 12 0 12 0 -13.1 0 -12.9 -13.3 01/26/2005 05:40:00 16.1 0.9 17.9 13 16 1 17.9 13 0.4 0 0.4 0.4 44 4 40 305 11 0 12 0 -13.2 0 -12.9 -13.3 01/26/2005 05:50:00 16.3 0.9 18.3 13.7 16.1 1 18.3 13.7 0.4 0 0.4 0.4 46 4 46 305 11 0 11 0 -13.2 0.1 -12.9 -13.3 01/26/2005 06:00:00 15.4 0.8 17.2 13.3 15.3 1 17.2 12.6 0.4 0 0.4 0.4 45 4 45 305 12 0 12 0 -13.1 0 -12.7 -13.3 01/26/2005 06:10:00 15 1 17.6 12.6 14.7 1 16.8 12.2 0.4 0 0.4 0.4 49 5 49 305 12 0 12 0 -13 0.1 -12.5 -13.1 01/26/2005 06:20:00 15 1 17.6 12.6 14.9 1 17.2 12.6 0.4 0 0.4 0.4 45 4 45 305 12 0 12 0 -12.9 0 -12.5 -12.9 01/26/2005 06:30:00 14.9 0.9 17.6 13 14.8 1 17.2 12.2 0.4 0 0.4 0.4 42 4 39 305 12 0 12 0 -12.9 0.1 -12.5 -13.1 01/26/2005 06:40:00 15.6 1 17.6 13 15.4 1.1 17.6 13 0.4 0 0.4 0.4 44 5 41 305 12 0 12 0 -12.9 0.1 -12.5 -13.1 01/26/2005 06:50:00 15.5 1 17.6 13 15.3 1 17.6 12.2 0.4 0 0.4 0.4 43 4 41 305 12 0 12 0 -13 0.1 -12.5 -13.1 01/26/2005 07:00:00 15.9 1.2 18.7 12.6 15.7 1.3 18.7 13 0.4 0 0.4 0.4 45 4 43 305 12 0 12 0 -13 0.1 -12.5 -13.1 01/26/2005 07:10:00 15.6 1.2 18.3 11.8 15.4 1.3 18.7 11.8 0.4 0 0.4 0.4 46 5 42 305 12 0 12 0 -13 0.1 -12.5 -13.1 01/26/2005 07:20:00 15.7 0.8 17.9 13 15.5 0.9 17.9 13 0.4 0 0.4 0.4 46 4 49 305 12 0 12 0 -13 0.1 -12.5 -13.1 01/26/2005 07:30:00 14.8 1.2 17.6 11.8 14.7 1.2 17.9 11.8 0.4 0 0.4 0.4 45 5 46 305 12 0 12 0 -13.1 0 -12.7 -13.3 01/26/2005 07:40:00 14.6 1.2 17.6 12.2 14.5 1.3 17.9 11.8 0.4 0 0.4 0.4 43 4 46 305 12 0 12 0 -13.1 0 -12.7 -13.3 01/26/2005 07:50:00 15.5 1.2 18.3 12.2 15.3 1.2 18.7 11.5 0.4 0 0.4 0.4 46 4 50 305 12 0 12 0 -13.2 0 -12.9 -13.3 01/26/2005 08:00:00 15.7 1 17.9 12.6 15.5 1 17.9 12.6 0.4 0 0.4 0.4 44 6 41 305 11 0 12 0 -13.3 0 -12.9 -13.5 01/26/2005 08:10:00 16.1 1.4 19.1 12.2 16 1.5 19.5 11.8 0.4 0 0.4 0.4 46 4 47 305 11 0 11 0 -13.3 0 -12.9 -13.5 01/26/2005 08:20:00 15.2 1 17.9 12.6 15.1 1.1 18.3 12.2 0.4 0 0.4 0.4 45 5 42 305 11 0 11 0 -13.3 0 -12.9 -13.5 01/26/2005 08:30:00 14.3 1.1 17.2 11.8 14.2 1.2 17.2 11.8 0.4 0 0.4 0.4 45 5 48 305 11 0 11 0 -13.3 0 -12.9 -13.5 01/26/2005 08:40:00 14 1 16.4 11.5 13.9 1.1 16.1 11.1 0.4 0 0.4 0.4 45 5 40 305 11 0 11 0 -13.2 0 -12.9 -13.3 01/26/2005 08:50:00 13.5 0.8 15.6 11.1 13.5 0.8 15.6 11.1 0.4 0 0.4 0.4 42 5 46 305 11 0 12 0 -13.3 0.1 -12.9 -13.5 01/26/2005 09:00:00 14.2 0.9 16.4 11.8 14.1 1 16.4 11.1 0.4 0 0.4 0.4 44 3 46 305 11 0 11 0 -13.3 0 -12.9 -13.5 01/26/2005 09:10:00 14.7 0.9 17.2 11.8 14.5 1 16.8 12.2 0.4 0 0.4 0.4 45 4 39 305 11 0 11 0 -13.2 0 -12.9 -13.3 01/26/2005 09:20:00 13.7 0.8 15.6 11.8 13.6 0.8 15.6 11.1 0.4 0 0.4 0.4 42 4 50 305 12 0 12 0 -13.2 0 -12.9 -13.3 01/26/2005 09:30:00 13.9 0.8 16.4 11.8 13.7 0.9 16.1 11.5 0.4 0 0.4 0.4 43 3 42 305 11 0 12 0 -13.3 0 -12.9 -13.5 01/26/2005 09:40:00 13.8 0.7 15.6 11.1 13.6 0.8 15.6 11.1 0.4 0 0.4 0.4 44 4 51 305 11 0 11 0 -13.3 0 -12.9 -13.5 01/26/2005 09:50:00 14 0.8 16.1 11.8 14 0.9 16.1 11.8 0.4 0 0.4 0.4 45 4 41 305 11 0 11 0 -13.3 0 -12.9 -13.5 01/26/2005 10:00:00 14.1 0.8 15.6 11.8 14 0.8 15.6 11.5 0.4 0 0.4 0.4 44 4 45 305 11 0 11 0 -13.3 0 -12.9 -13.3 01/26/2005 10:10:00 14 0.8 16.1 12.2 13.8 0.9 16.1 11.1 0.4 0 0.4 0.4 46 4 52 305 11 0 11 0 -13.2 0.1 -12.9 -13.3 01/26/2005 10:20:00 14.5 0.9 16.4 11.8 14.3 1 16.8 11.1 0.4 0 0.4 0.4 43 3 44 305 11 0 11 0 -13.3 0.1 -12.9 -13.5 01/26/2005 10:30:00 14.4 0.9 16.4 12.2 14.4 1 16.4 12.2 0.4 0 0.4 0.4 48 3 46 305 11 0 11 0 -13.2 0 -12.9 -13.5 01/26/2005 10:40:00 14.8 1.1 17.6 12.2 14.8 1.1 17.6 12.2 0.4 0 0.4 0.4 49 3 46 305 11 0 12 0 -13.1 0 -12.9 -13.3 01/26/2005 10:50:00 14.5 1 17.2 11.8 14.4 1.1 17.6 11.5 0.4 0 0.4 0.4 51 3 49 305 12 0 12 0 -13.1 0 -12.7 -13.3 01/26/2005 11:00:00 13.8 0.7 15.6 11.5 13.7 0.8 15.6 11.5 0.4 0 0.4 0.4 53 4 54 305 12 0 12 0 -12.9 0.1 -12.5 -13.1 01/26/2005 11:10:00 14.1 0.8 15.6 11.5 14.1 0.8 16.1 11.5 0.4 0 0.4 0.4 54 4 48 305 12 0 12 0 -12.8 0 -12.5 -12.9 01/26/2005 11:20:00 14.8 0.9 16.4 12.2 14.7 1 16.4 11.8 0.4 0 0.4 0.4 53 3 51 305 12 0 12 0 -12.8 0 -12.5 -12.9 01/26/2005 11:30:00 15 0.7 16.8 13.3 14.8 0.7 16.8 13 0.4 0 0.4 0.4 50 3 51 305 12 0 12 0 -12.7 0 -12.3 -12.9 01/26/2005 11:40:00 13.7 1.1 16.4 11.5 13.6 1.1 16.4 11.5 0.4 0 0.4 0.4 50 4 47 305 12 0 13 0 -12.6 0 -12.1 -12.9 01/26/2005 11:50:00 14.2 0.9 16.4 11.5 14.1 0.8 16.1 11.5 0.4 0 0.4 0.4 49 4 49 305 13 0 13 0 -12.5 0 -12.1 -12.7 01/26/2005 12:00:00 14 0.9 16.4 11.8 13.9 1 16.8 11.5 0.4 0 0.4 0.4 47 4 45 305 13 0 13 0 -12.5 0.1 -12.1 -12.7 01/26/2005 12:10:00 14.2 0.8 16.8 11.8 14.2 0.9 17.2 11.5 0.4 0 0.4 0.4 50 4 51 305 13 0 13 0 -12.5 0.1 -12.1 -12.5 01/26/2005 12:20:00 13.7 0.6 15.6 11.8 13.6 0.7 15.6 11.5 0.4 0 0.4 0.4 48 4 44 305 13 0 13 0 -12.4 0.1 -12.1 -12.5 01/26/2005 12:30:00 15 1 17.6 12.2 14.9 1 17.6 12.6 0.4 0 0.4 0.4 51 3 56 305 13 0 13 0 -12.4 0.1 -11.9 -12.5 01/26/2005 12:40:00 14.5 1 16.4 11.8 14.3 1.1 16.8 11.8 0.4 0 0.4 0.4 54 4 57 305 13 0 13 0 -12.3 0 -12.1 -12.5 01/26/2005 12:50:00 14.1 0.7 15.6 11.8 14 0.8 15.6 11.8 0.4 0 0.4 0.4 53 4 57 305 13 0 13 0 -12.4 0 -12.1 -12.5 01/26/2005 13:00:00 13.7 0.8 15.6 11.8 13.5 0.9 15.6 11.5 0.4 0 0.4 0.4 55 3 57 305 14 0 14 0 -12.2 0 -11.9 -12.5 01/26/2005 13:10:00 14.3 0.8 16.4 11.8 14.1 1 16.8 11.1 0.4 0 0.4 0.4 57 4 52 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/26/2005 13:20:00 14.9 0.7 16.4 13 14.9 0.8 16.4 12.2 0.4 0 0.4 0.4 60 4 58 305 13 0 14 0 -12.4 0.1 -12.1 -12.5 01/26/2005 13:30:00 14.8 0.6 16.4 13.3 14.8 0.7 16.8 12.2 0.4 0 0.4 0.4 61 2 60 305 13 0 14 0 -12.4 0 -12.1 -12.5 01/26/2005 13:40:00 15.2 0.6 16.8 13.3 15.2 0.7 17.2 13 0.4 0 0.4 0.4 60 2 57 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/26/2005 13:50:00 16.1 0.5 17.2 14.5 16 0.6 17.6 14.5 0.4 0 0.4 0.4 60 2 60 305 14 0 14 0 -12.4 0.1 -12.1 -12.5 01/26/2005 14:00:00 15.2 0.6 16.4 13.3 15.1 0.7 16.8 13 0.4 0 0.4 0.4 59 3 60 305 14 0 14 0 -12.3 0 -11.9 -12.5 01/26/2005 14:10:00 15.2 0.7 16.8 12.6 15.2 0.8 17.6 12.2 0.4 0 0.4 0.4 57 3 53 305 14 0 13 0 -12.3 0 -12.1 -12.5 01/26/2005 14:20:00 14.8 0.7 16.8 12.6 14.8 0.8 16.8 12.2 0.4 0 0.4 0.4 56 4 54 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/26/2005 14:30:00 15 1 16.8 11.5 14.9 1.1 16.8 11.5 0.4 0 0.4 0.4 55 3 52 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/26/2005 14:40:00 14.6 0.8 16.8 11.8 14.5 1 17.2 11.5 0.4 0 0.4 0.4 56 3 51 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/26/2005 14:50:00 13.9 0.7 15.3 11.5 14 0.8 15.6 11.5 0.4 0 0.4 0.4 58 3 51 305 14 0 14 0 -12.2 0 -11.9 -12.5 01/26/2005 15:00:00 14 0.8 15.6 11.1 14 0.9 16.1 10.7 0.4 0 0.4 0.4 55 4 57 305 14 0 14 0 -12.2 0 -11.9 -12.5 01/26/2005 15:10:00 14.2 0.7 16.1 11.1 14.2 0.9 16.1 11.5 0.4 0 0.4 0.4 56 3 54 305 14 0 14 0 -12.3 0 -11.9 -12.5 01/26/2005 15:20:00 14.1 0.8 16.4 11.5 14 1 16.4 11.1 0.4 0 0.4 0.4 54 4 60 305 14 0 14 0 -12.3 0 -12.1 -12.5 01/26/2005 15:30:00 13.8 1 16.1 11.5 13.6 1.1 15.6 10.3 0.4 0 0.4 0.4 54 4 52 305 14 0 14 0 -12.3 0 -11.9 -12.5 01/26/2005 15:40:00 13.1 1.1 15.3 9.5 13 1.2 15.3 9.1 0.4 0 0.4 0.4 51 5 57 305 14 0 14 0 -12.2 0 -11.7 -12.5 01/26/2005 15:50:00 12.9 0.9 14.9 10.7 12.7 1 14.9 10.3 0.4 0 0.4 0.4 49 5 50 305 15 0 14 0 -12.1 0 -11.7 -12.3 01/26/2005 16:00:00 10.6 1.2 13.7 8.4 10.3 1.2 13.3 7.2 0.4 0 0.4 0.4 45 5 45 305 15 0 15 0 -12 0 -11.7 -12.1 01/26/2005 16:10:00 10.8 0.9 13 8.8 10.6 0.9 12.2 8.4 0.4 0 0.4 0.4 43 4 40 305 15 0 15 0 -12 0 -11.5 -12.1 01/26/2005 16:20:00 9.8 1 11.8 7.2 9.5 1.1 11.8 6.5 0.4 0 0.4 0.4 41 5 37 305 15 0 15 0 -11.9 0.1 -11.5 -12.1 01/26/2005 16:30:00 9.2 0.7 11.5 7.2 8.9 0.8 11.1 6.8 0.4 0 0.4 0.4 34 5 37 305 15 0 15 0 -11.9 0.1 -11.5 -12.1 01/26/2005 16:40:00 8.8 0.5 10.7 7.2 8.6 0.6 10.3 7.2 0.4 0 0.4 0.4 33 4 30 305 15 0 15 0 -11.8 0.1 -11.5 -12.1 01/26/2005 16:50:00 8.9 0.5 9.5 7.2 8.7 0.5 10.3 7.2 0.4 0 0.4 0.4 27 3 24 305 15 0 15 0 -12 0 -11.5 -12.1 01/26/2005 17:00:00 9.6 0.8 11.5 7.6 9.4 0.9 11.1 7.2 0.4 0 0.4 0.4 30 3 29 305 15 0 15 0 -12 0 -11.7 -12.1 01/26/2005 17:10:00 11.1 0.7 12.2 8.8 10.9 0.8 12.2 8.8 0.4 0 0.4 0.4 34 3 30 305 15 0 15 0 -12 0 -11.7 -12.1 01/26/2005 17:20:00 11.9 0.8 13.7 9.1 11.7 0.9 13.3 8.8 0.4 0 0.4 0.4 38 4 40 305 15 0 15 0 -11.9 0 -11.7 -12.1 01/26/2005 17:30:00 12.9 0.8 14.9 10.3 12.8 0.9 14.5 10.3 0.4 0 0.4 0.4 39 4 42 305 15 0 15 0 -11.9 0 -11.5 -12.1 01/26/2005 17:40:00 13.3 0.6 14.5 11.5 13.1 0.7 14.9 10.7 0.4 0 0.4 0.4 40 3 36 305 15 0 15 0 -11.9 0 -11.7 -12.1 01/26/2005 17:50:00 13.9 0.7 15.3 11.8 13.8 0.8 15.6 11.1 0.4 0 0.4 0.4 40 3 42 305 14 0 15 0 -12 0 -11.9 -12.1 01/26/2005 18:00:00 13.5 0.6 14.9 11.5 13.4 0.8 14.9 11.5 0.4 0 0.4 0.4 42 3 41 305 14 0 14 0 -11.9 0.1 -11.5 -12.1 01/26/2005 18:10:00 13.2 0.8 15.3 10.7 13.1 0.9 15.3 10.7 0.4 0 0.4 0.4 44 4 44 305 15 0 14 0 -11.8 0.1 -11.5 -12.1 01/26/2005 18:20:00 13.9 0.9 16.1 11.8 13.8 1 16.4 11.1 0.4 0 0.4 0.4 43 3 40 305 15 0 14 0 -11.8 0.1 -11.5 -12.1 01/26/2005 18:30:00 14 1 16.1 11.1 14 1.1 16.4 10.7 0.4 0 0.4 0.4 44 3 46 305 15 0 15 0 -11.8 0 -11.5 -11.9 01/26/2005 18:40:00 13.8 0.7 16.1 11.8 13.7 0.8 16.1 11.1 0.4 0 0.4 0.4 41 4 39 305 15 0 15 0 -11.7 0 -11.3 -11.9 01/26/2005 18:50:00 13 1 15.6 9.9 12.9 1 15.6 10.7 0.4 0 0.4 0.4 40 4 44 305 15 0 15 0 -11.8 0 -11.5 -11.9 01/26/2005 19:00:00 12.9 0.9 14.9 11.1 12.9 0.9 14.9 10.7 0.4 0 0.4 0.4 42 4 48 305 15 0 15 0 -11.8 0 -11.5 -11.9 01/26/2005 19:10:00 12 0.8 13.7 9.5 11.8 0.8 13.7 9.5 0.4 0 0.4 0.4 37 5 29 305 15 0 15 0 -11.8 0 -11.5 -11.9 01/26/2005 19:20:00 11.9 1 14.1 9.5 11.8 1.1 14.5 9.1 0.4 0 0.4 0.4 39 4 36 305 15 0 15 0 -11.8 0.1 -11.5 -12.1 01/26/2005 19:30:00 13.3 0.9 15.6 10.3 13.2 1 15.3 10.3 0.4 0 0.4 0.4 37 3 32 305 15 0 14 0 -11.7 0 -11.5 -11.9 01/26/2005 19:40:00 12.7 0.9 15.3 10.7 12.5 0.9 14.9 9.9 0.4 0 0.4 0.4 36 5 33 305 15 0 15 0 -11.7 0 -11.3 -11.9 01/26/2005 19:50:00 13.1 0.7 14.9 10.3 13.1 0.8 14.9 10.3 0.4 0 0.4 0.4 36 4 35 305 15 0 15 0 -11.8 0.1 -11.3 -12.1 01/26/2005 20:00:00 13.3 0.8 15.3 10.7 13.2 0.9 15.3 10.7 0.4 0 0.4 0.4 37 4 32 305 15 0 15 0 -11.8 0.1 -11.5 -12.1 01/26/2005 20:10:00 13.7 0.9 15.6 10.7 13.6 1 16.1 10.7 0.4 0 0.4 0.4 41 5 41 305 15 0 15 0 -11.8 0.1 -11.5 -12.1 01/26/2005 20:20:00 14.1 0.7 16.1 12.2 14 0.7 16.1 12.2 0.4 0 0.4 0.4 39 3 35 305 14 0 14 0 -11.9 0.1 -11.7 -12.1 01/26/2005 20:30:00 14.4 1 16.4 12.2 14.4 1 16.4 11.1 0.4 0 0.4 0.4 40 4 42 305 14 0 14 0 -12 0 -11.7 -12.3 01/26/2005 20:40:00 15 1 17.2 12.6 14.8 1.2 17.6 12.2 0.4 0 0.4 0.4 41 3 41 305 14 0 14 0 -12.2 0.1 -11.9 -12.5 01/26/2005 20:50:00 13.8 1 16.4 11.5 13.7 1 16.4 11.8 0.4 0 0.4 0.4 44 4 44 305 14 0 14 0 -12.3 0.1 -12.1 -12.5 01/26/2005 21:00:00 14.2 0.8 16.4 11.8 14.2 0.9 16.4 11.8 0.4 0 0.4 0.4 48 3 47 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/26/2005 21:10:00 14.4 0.8 16.4 11.8 14.3 1 16.1 11.8 0.4 0 0.4 0.4 48 4 46 305 13 0 13 0 -12.5 0 -12.1 -12.7 01/26/2005 21:20:00 14.4 0.8 16.1 12.6 14.2 0.9 16.4 11.8 0.4 0 0.4 0.4 47 4 53 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/26/2005 21:30:00 14.2 0.9 16.1 11.8 14.1 1 16.4 11.1 0.4 0 0.4 0.4 46 4 41 305 13 0 13 0 -12.5 0 -12.1 -12.7 01/26/2005 21:40:00 13.9 0.8 15.6 11.8 13.9 0.9 15.6 11.1 0.4 0 0.4 0.4 45 3 47 305 13 0 13 0 -12.5 0 -12.1 -12.7 01/26/2005 21:50:00 13.2 0.8 15.3 11.1 13.1 0.9 15.3 10.7 0.4 0 0.4 0.4 45 3 44 305 13 0 13 0 -12.6 0 -12.3 -12.7 01/26/2005 22:00:00 13.4 0.6 15.3 11.5 13.3 0.6 14.9 11.1 0.4 0 0.4 0.4 45 3 45 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/26/2005 22:10:00 13.1 0.7 15.3 10.7 13 0.7 14.9 10.7 0.4 0 0.4 0.4 45 3 43 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/26/2005 22:20:00 13 0.7 14.9 10.7 12.9 0.8 15.3 11.1 0.4 0 0.4 0.4 45 4 42 305 13 0 13 0 -12.5 0 -12.1 -12.5 01/26/2005 22:30:00 13.3 0.6 15.3 11.5 13.3 0.7 15.6 11.5 0.4 0 0.4 0.4 45 4 44 305 13 0 13 0 -12.5 0 -12.3 -12.5 01/26/2005 22:40:00 13.3 0.7 15.3 11.5 13.1 0.8 15.6 11.1 0.4 0 0.4 0.4 44 4 57 305 13 0 13 0 -12.5 0.1 -12.1 -12.5 01/26/2005 22:50:00 13.3 0.7 15.3 11.5 13.2 0.7 15.3 11.5 0.4 0 0.4 0.4 44 4 45 305 13 0 13 0 -12.4 0.1 -12.1 -12.5 01/26/2005 23:00:00 13.7 0.8 16.1 11.8 13.5 0.9 15.6 11.5 0.4 0 0.4 0.4 44 4 36 305 13 0 13 0 -12.3 0 -12.1 -12.5 01/26/2005 23:10:00 13.8 1 16.4 11.5 13.7 1.1 16.1 10.7 0.4 0 0.4 0.4 44 5 46 305 13 0 13 0 -12.2 0 -11.9 -12.5 01/26/2005 23:20:00 13.9 0.8 16.1 11.8 13.8 1 16.1 10.7 0.4 0 0.4 0.4 40 4 46 305 13 0 13 0 -12.1 0 -11.7 -12.3 01/26/2005 23:30:00 13.6 0.8 16.1 11.5 13.5 0.8 15.6 11.1 0.4 0 0.4 0.4 38 4 38 305 13 0 13 0 -12.2 0 -11.7 -12.5 01/26/2005 23:40:00 13.6 1 16.4 11.5 13.6 1 16.4 10.7 0.4 0 0.4 0.4 37 4 33 305 13 0 13 0 -12.3 0 -11.9 -12.5 01/26/2005 23:50:00 13.6 0.6 15.3 11.1 13.4 0.7 15.3 10.7 0.4 0 0.4 0.4 38 3 37 305 13 0 13 0 -12.4 0.1 -12.1 -12.5 01/27/2005 00:00:00 13.3 0.9 15.6 11.5 13.2 0.9 15.3 11.1 0.4 0 0.4 0.4 37 4 33 305 13 0 13 0 -12.5 0 -12.1 -12.7 01/27/2005 00:10:00 13.2 1 15.6 11.1 13.1 1 15.3 10.7 0.4 0 0.4 0.4 40 4 35 305 13 0 13 0 -12.6 0 -12.1 -12.9 01/27/2005 00:20:00 12.5 0.9 14.9 10.3 12.4 1 14.1 9.5 0.4 0 0.4 0.4 41 4 39 305 12 0 12 0 -12.8 0.1 -12.5 -12.9 01/27/2005 00:30:00 12.9 0.8 14.9 11.1 12.8 0.8 14.9 10.7 0.4 0 0.4 0.4 41 4 33 305 12 0 12 0 -12.9 0.1 -12.5 -13.1 01/27/2005 00:40:00 12.9 0.8 15.6 11.1 12.7 0.9 15.6 11.1 0.4 0 0.4 0.4 43 4 40 305 12 0 12 0 -13 0.1 -12.7 -13.1 01/27/2005 00:50:00 12.5 0.7 14.5 10.3 12.4 0.7 14.5 10.3 0.4 0 0.4 0.4 44 4 48 305 12 0 12 0 -13 0.1 -12.7 -13.1 01/27/2005 01:00:00 12.4 1 15.6 10.3 12.4 1 15.6 9.5 0.4 0 0.4 0.4 44 5 41 305 11 0 12 0 -13 0 -12.7 -13.3 01/27/2005 01:10:00 13.3 0.9 15.6 11.1 13.1 1 15.6 10.3 0.4 0 0.4 0.4 45 5 52 305 11 0 11 0 -13 0 -12.7 -13.3 01/27/2005 01:20:00 13.1 0.9 16.1 10.7 13 1 15.6 9.9 0.4 0 0.4 0.4 45 5 43 305 11 0 11 0 -13 0 -12.7 -13.3 01/27/2005 01:30:00 13.1 1 16.1 10.3 13 1.1 16.1 10.7 0.4 0 0.4 0.4 44 5 43 305 11 0 11 0 -13 0 -12.7 -13.1 01/27/2005 01:40:00 11.6 0.7 13.7 9.9 11.5 0.7 13.7 9.9 0.4 0 0.4 0.4 39 4 41 305 11 0 11 0 -13.3 0.2 -12.9 -13.7 01/27/2005 01:50:00 11.6 0.7 13.3 9.5 11.4 0.7 13.3 9.5 0.4 0 0.4 0.4 43 5 37 305 11 0 11 0 -13.7 0 -13.3 -13.9 01/27/2005 02:00:00 11 0.8 13.3 9.1 10.9 0.8 13 8.8 0.4 0 0.4 0.4 44 5 43 305 11 0 11 0 -13.7 0 -13.3 -13.9 01/27/2005 02:10:00 10.8 0.8 13 9.1 10.8 0.8 13 8.8 0.4 0 0.4 0.4 45 5 44 305 10 0 10 0 -13.9 0 -13.5 -14.1 01/27/2005 02:20:00 10.8 0.7 13 9.1 10.7 0.7 12.6 9.1 0.4 0 0.4 0.4 46 4 40 305 10 0 10 0 -13.9 0 -13.7 -14.3 01/27/2005 02:30:00 11 0.8 13.3 9.1 11.1 0.8 13.3 8.8 0.4 0 0.4 0.4 46 5 45 305 10 0 10 0 -13.9 0 -13.7 -14.1 01/27/2005 02:40:00 11.6 1 14.1 9.1 11.6 1 14.1 8.8 0.4 0 0.4 0.4 47 5 46 305 10 0 10 0 -13.9 0 -13.7 -14.1 01/27/2005 02:50:00 12.2 1 15.3 9.5 12.1 1 14.5 9.9 0.4 0 0.4 0.4 47 5 57 305 10 0 10 0 -13.7 0 -13.5 -14.1 01/27/2005 03:00:00 12.2 0.9 14.5 10.3 12.2 1 15.3 9.1 0.4 0 0.4 0.4 45 5 40 305 11 0 11 0 -13.5 0 -13.1 -13.7 01/27/2005 03:10:00 12.1 1 14.9 9.5 12 1 14.9 9.9 0.4 0 0.4 0.4 43 5 43 305 11 0 11 0 -13.4 0.1 -13.1 -13.5 01/27/2005 03:20:00 12.6 1.1 16.1 10.3 12.5 1.1 15.6 10.3 0.4 0 0.4 0.4 42 5 49 305 11 0 11 0 -13.4 0 -13.1 -13.7 01/27/2005 03:30:00 13.1 0.8 15.6 11.1 12.8 0.9 14.9 10.7 0.4 0 0.4 0.4 43 5 36 305 11 0 11 0 -13.4 0.1 -12.9 -13.7 01/27/2005 03:40:00 13.7 1 16.1 11.5 13.7 1 16.4 11.5 0.4 0 0.4 0.4 46 4 41 305 11 0 11 0 -13.4 0 -12.9 -13.5 01/27/2005 03:50:00 13.9 1.1 16.8 11.1 13.8 1.1 16.1 11.1 0.4 0 0.4 0.4 47 5 42 305 11 0 11 0 -13.4 0.1 -12.9 -13.7 01/27/2005 04:00:00 13.5 0.9 16.4 11.5 13.3 1 16.4 10.3 0.4 0 0.4 0.4 47 5 48 305 11 0 11 0 -13.4 0 -13.1 -13.5 01/27/2005 04:10:00 13.7 1 16.1 11.1 13.6 1 16.1 11.1 0.4 0 0.4 0.4 47 4 41 305 11 0 11 0 -13.4 0 -13.1 -13.7 01/27/2005 04:20:00 14 1 16.4 11.1 13.9 1.1 16.4 11.5 0.4 0 0.4 0.4 48 5 52 305 11 0 11 0 -13.4 0 -12.9 -13.5 01/27/2005 04:30:00 15 1 17.6 12.6 14.8 1.1 17.6 11.8 0.4 0 0.4 0.4 46 4 54 305 11 0 11 0 -13.4 0 -13.1 -13.7 01/27/2005 04:40:00 15.3 1 17.6 12.6 15 1 17.9 12.6 0.4 0 0.4 0.4 45 4 44 305 10 0 11 0 -13.5 0.1 -13.1 -13.7 01/27/2005 04:50:00 15.1 1.1 18.3 12.2 14.9 1.2 17.9 12.6 0.4 0 0.4 0.4 45 4 48 305 10 0 10 0 -13.6 0 -13.1 -13.7 01/27/2005 05:00:00 14.2 1 16.4 11.8 14 1.1 17.2 11.5 0.4 0 0.4 0.4 43 4 40 305 10 0 10 0 -13.7 0 -13.3 -13.9 01/27/2005 05:10:00 14.2 1 17.6 12.2 14 1 17.2 11.1 0.4 0 0.4 0.4 44 4 41 305 10 0 10 0 -13.7 0 -13.5 -13.7 01/27/2005 05:20:00 12.9 1 15.6 11.1 12.8 0.9 16.1 10.7 0.4 0 0.4 0.4 46 4 43 305 10 0 10 0 -13.7 0 -13.7 -13.9 01/27/2005 05:30:00 13.6 1.1 16.8 10.7 13.4 1.1 16.8 10.3 0.4 0 0.4 0.4 44 5 44 305 10 0 10 0 -13.8 0 -13.7 -14.1 01/27/2005 05:40:00 13.9 1 16.1 11.1 13.7 1.1 16.8 10.7 0.4 0 0.4 0.4 45 4 46 305 10 0 10 0 -13.9 0 -13.7 -14.3 01/27/2005 05:50:00 14.5 1 16.8 12.2 14.3 1 16.4 11.5 0.4 0 0.4 0.4 43 4 48 305 10 0 10 0 -14 0 -13.7 -14.3 01/27/2005 06:00:00 14.8 0.9 17.2 12.2 14.7 1 17.2 12.2 0.4 0 0.4 0.4 41 4 38 305 10 0 9 0 -14.1 0 -13.7 -14.3 01/27/2005 06:10:00 15 1 17.9 13 14.8 1 17.6 12.2 0.4 0 0.4 0.4 41 4 41 305 9 0 9 0 -14.1 0 -13.7 -14.3 01/27/2005 06:20:00 14.5 0.8 16.8 12.2 14.4 0.9 16.4 12.2 0.4 0 0.4 0.4 40 3 45 305 9 0 9 0 -14.2 0 -14.1 -14.3 01/27/2005 06:30:00 15 0.8 17.6 12.6 14.9 0.9 17.6 12.6 0.4 0 0.4 0.4 42 3 44 305 9 0 9 0 -14.2 0 -13.7 -14.3 01/27/2005 06:40:00 13.7 0.9 15.6 11.1 13.6 1 16.1 10.7 0.4 0 0.4 0.4 41 4 39 305 9 0 9 0 -14.2 0 -13.7 -14.3 01/27/2005 06:50:00 13 0.8 15.6 10.7 12.9 1 15.3 10.7 0.4 0 0.4 0.4 41 3 41 305 9 0 9 0 -14.2 0 -13.7 -14.3 01/27/2005 07:00:00 11.4 0.8 13.3 8.8 11.3 0.8 13 8.8 0.4 0 0.4 0.4 40 4 40 305 9 0 9 0 -14.3 0 -13.9 -14.4 01/27/2005 07:10:00 10.5 0.9 12.6 8.8 10.5 1 13 8 0.4 0 0.4 0.4 39 4 39 305 9 0 9 0 -14.2 0 -13.9 -14.4 01/27/2005 07:20:00 10.4 0.9 12.6 8.4 10.2 0.8 12.2 8 0.4 0 0.4 0.4 39 5 43 305 9 0 9 0 -14.2 0 -13.9 -14.4 01/27/2005 07:30:00 10.6 0.9 13 8.8 10.6 0.9 13 8.4 0.4 0 0.4 0.4 41 6 36 305 9 0 9 0 -14.3 0 -13.9 -14.4 01/27/2005 07:40:00 10.2 1.1 13 7.6 10.2 1.2 13.3 7.2 0.4 0 0.4 0.4 46 7 58 305 9 0 9 0 -14.3 0 -14.1 -14.4 01/27/2005 07:50:00 11.8 1.3 15.6 8.8 11.6 1.3 14.9 8.4 0.4 0 0.4 0.4 45 5 42 305 9 0 9 0 -14.4 0 -14.1 -14.6 01/27/2005 08:00:00 13.2 1 15.6 11.1 13.1 1.1 15.6 10.7 0.4 0 0.4 0.4 46 5 46 305 9 0 9 0 -14.4 0 -14.1 -14.6 01/27/2005 08:10:00 12.6 1 15.3 10.3 12.5 1 15.3 9.9 0.4 0 0.4 0.4 45 5 48 305 9 0 9 0 -14.5 0.1 -14.3 -14.6 01/27/2005 08:20:00 12.2 0.9 14.1 9.1 12.2 1 14.1 9.1 0.4 0 0.4 0.4 45 4 41 305 8 0 8 0 -14.5 0 -14.3 -14.6 01/27/2005 08:30:00 11.3 0.9 13.7 9.1 11.2 0.9 13.7 9.1 0.4 0 0.4 0.4 45 4 40 305 8 0 8 0 -14.5 0.1 -14.3 -14.6 01/27/2005 08:40:00 10.8 1 13.7 8 10.6 1 13.7 8.4 0.4 0 0.4 0.4 44 5 57 305 8 0 8 0 -14.5 0.1 -14.3 -14.6 01/27/2005 08:50:00 10.6 1 13.7 8.4 10.5 1.1 13.7 8 0.4 0 0.4 0.4 45 6 46 305 8 0 8 0 -14.5 0 -14.3 -14.6 01/27/2005 09:00:00 11.1 1 13.7 8.8 11 1 13.7 8.4 0.4 0 0.4 0.4 45 5 50 305 8 0 8 0 -14.5 0 -14.3 -14.6 01/27/2005 09:10:00 10.8 1.2 13.3 8.4 10.7 1.2 13.3 8 0.4 0 0.4 0.4 44 6 39 305 8 0 8 0 -14.6 0 -14.3 -14.6 01/27/2005 09:20:00 11.8 0.8 13.7 9.1 11.7 0.9 14.5 9.1 0.4 0 0.4 0.4 44 5 43 305 8 0 8 0 -14.6 0 -14.4 -14.6 01/27/2005 09:30:00 12.5 0.8 14.9 9.9 12.5 1 14.9 10.3 0.4 0 0.4 0.4 43 4 52 305 8 0 8 0 -14.7 0 -14.4 -14.6 01/27/2005 09:40:00 12.4 0.9 15.3 10.3 12.3 1 15.3 9.9 0.4 0 0.4 0.4 42 4 45 305 8 0 8 0 -14.7 0 -14.6 -14.8 01/27/2005 09:50:00 13.1 0.8 15.6 10.7 13.1 0.8 16.1 11.1 0.4 0 0.4 0.4 44 4 41 305 8 0 8 0 -14.7 0 -14.4 -14.6 01/27/2005 10:00:00 11.7 1 14.5 9.5 11.6 1 14.5 9.1 0.4 0 0.4 0.4 44 5 37 305 8 0 8 0 -14.7 0 -14.3 -14.8 01/27/2005 10:10:00 10.9 0.8 13 8.8 10.7 0.8 12.6 8.4 0.4 0 0.4 0.4 42 5 48 305 8 0 8 0 -14.7 0 -14.3 -14.8 01/27/2005 10:20:00 10.6 0.9 13.3 8.4 10.5 0.9 13 8.4 0.4 0 0.4 0.4 36 6 37 305 8 0 8 0 -14.8 0.1 -14.3 -15 01/27/2005 10:30:00 11 0.7 14.1 9.1 10.8 0.8 14.1 9.1 0.4 0 0.4 0.4 34 4 40 305 8 0 8 0 -15.2 0 -14.8 -15.2 01/27/2005 10:40:00 12.7 1 15.3 10.3 12.6 1 15.6 9.9 0.4 0 0.4 0.4 39 4 38 305 8 0 8 0 -14.8 0 -14.6 -15 01/27/2005 10:50:00 12.7 0.8 14.5 10.3 12.6 0.9 14.5 9.9 0.4 0 0.4 0.4 40 4 43 305 8 0 8 0 -14.8 0 -14.4 -14.8 01/27/2005 11:00:00 12.7 0.8 14.9 10.3 12.6 0.9 15.3 10.3 0.4 0 0.4 0.4 40 4 44 305 8 0 8 0 -14.8 0 -14.4 -15 01/27/2005 11:10:00 13.1 0.9 15.3 10.7 12.9 1 15.3 10.7 0.4 0 0.4 0.4 41 4 41 305 8 0 8 0 -14.7 0 -14.4 -14.8 01/27/2005 11:20:00 12 0.8 13.3 9.5 12 0.8 13.7 9.9 0.4 0 0.4 0.4 40 4 40 305 8 0 8 0 -14.8 0 -14.4 -15 01/27/2005 11:30:00 11 0.8 13.3 9.5 10.9 0.8 13.7 9.1 0.4 0 0.4 0.4 39 4 36 305 8 0 8 0 -14.8 0 -14.4 -15 01/27/2005 11:40:00 9.8 0.7 11.8 8 9.7 0.8 11.5 8 0.4 0 0.4 0.4 40 4 35 305 8 0 8 0 -14.7 0 -14.4 -14.8 01/27/2005 11:50:00 9 0.8 11.5 6.8 8.8 0.8 11.5 6.8 0.4 0 0.4 0.4 37 5 31 305 8 0 8 0 -14.7 0 -14.3 -15 01/27/2005 12:00:00 9.4 1 12.2 7.2 9.3 1 12.2 7.2 0.4 0 0.4 0.4 35 6 35 305 8 0 8 0 -14.6 0 -14.3 -14.6 01/27/2005 12:10:00 9 0.9 11.1 7.2 8.9 0.9 11.1 6.8 0.4 0 0.4 0.4 37 6 39 305 8 0 8 0 -14.7 0 -14.3 -14.6 01/27/2005 12:20:00 8.9 0.7 11.1 7.6 8.7 0.7 10.7 6.8 0.4 0 0.4 0.4 40 6 41 305 8 0 8 0 -14.6 0.1 -14.3 -14.6 01/27/2005 12:30:00 8.2 0.8 10.7 6.5 8 0.8 10.7 6.1 0.4 0 0.4 0.4 41 7 38 305 8 0 8 0 -14.7 0 -14.3 -14.8 01/27/2005 12:40:00 8.6 0.9 11.1 6.5 8.4 0.9 11.1 6.5 0.4 0 0.4 0.4 41 7 31 305 8 0 8 0 -14.6 0.1 -14.3 -14.6 01/27/2005 12:50:00 8.7 0.7 10.7 7.2 8.6 0.8 10.7 6.8 0.4 0 0.4 0.4 42 6 38 305 8 0 8 0 -14.6 0.1 -14.3 -14.6 01/27/2005 13:00:00 9.1 0.9 11.5 6.8 9 0.9 11.5 6.8 0.4 0 0.4 0.4 41 6 39 305 8 0 8 0 -14.5 0.1 -14.1 -14.6 01/27/2005 13:10:00 9.5 0.7 11.5 7.6 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 42 6 43 305 9 0 9 0 -14.3 0 -13.9 -14.4 01/27/2005 13:20:00 9.8 0.8 12.2 8 9.7 0.8 11.8 7.6 0.4 0 0.4 0.4 41 5 41 305 9 0 9 0 -14.2 0 -13.7 -14.4 01/27/2005 13:30:00 11 0.9 13.7 8.8 10.8 1 13.3 8 0.4 0 0.4 0.4 44 5 42 305 9 0 9 0 -14.2 0 -13.9 -14.3 01/27/2005 13:40:00 11.6 1 14.1 8.8 11.4 1.1 13.7 8.8 0.4 0 0.4 0.4 43 5 37 305 9 0 9 0 -14.1 0 -13.7 -14.3 01/27/2005 13:50:00 11.8 1.1 14.9 8.8 11.7 1.1 14.1 8.8 0.4 0 0.4 0.4 44 5 42 305 9 0 9 0 -14.2 0 -14.1 -14.3 01/27/2005 14:00:00 12.4 1 14.9 9.1 12.2 1.1 15.6 9.1 0.4 0 0.4 0.4 45 6 48 305 9 0 9 0 -14.2 0 -13.7 -14.3 01/27/2005 14:10:00 13.3 1.2 16.4 10.7 13.2 1.2 16.4 10.3 0.4 0 0.4 0.4 42 5 43 305 9 0 9 0 -14.2 0 -13.7 -14.3 01/27/2005 14:20:00 13.5 1 16.1 10.3 13.3 1.2 16.1 9.9 0.4 0 0.4 0.4 44 5 41 305 9 0 9 0 -14.2 0 -13.7 -14.3 01/27/2005 14:30:00 13.9 1.2 16.8 10.7 13.8 1.4 17.2 9.9 0.4 0 0.4 0.4 44 5 41 305 9 0 9 0 -14.1 0 -13.9 -14.3 01/27/2005 14:40:00 12.6 1 15.6 9.9 12.5 1.1 16.4 9.9 0.4 0 0.4 0.4 45 5 39 305 9 0 9 0 -14.1 0 -13.9 -14.3 01/27/2005 14:50:00 12.5 1 15.6 9.9 12.4 1.1 15.3 9.5 0.4 0 0.4 0.4 45 5 41 305 9 0 9 0 -14 0 -13.7 -14.3 01/27/2005 15:00:00 12.5 1.1 14.9 9.5 12.3 1.1 15.3 9.5 0.4 0 0.4 0.4 46 5 46 305 9 0 9 0 -14 0 -13.7 -14.3 01/27/2005 15:10:00 12.5 1 14.9 9.5 12.3 1.1 14.9 9.5 0.4 0 0.4 0.4 46 5 46 305 9 0 9 0 -13.9 0 -13.7 -14.1 01/27/2005 15:20:00 12.2 1 15.6 9.5 12.1 1 16.1 9.9 0.4 0 0.4 0.4 46 6 41 305 9 0 9 0 -13.9 0 -13.5 -14.1 01/27/2005 15:30:00 13.2 1.2 16.4 10.3 13 1.3 16.1 9.5 0.4 0 0.4 0.4 45 5 53 305 9 0 9 0 -13.9 0 -13.5 -14.1 01/27/2005 15:40:00 12.9 0.9 15.3 10.3 12.8 1 14.9 9.9 0.4 0 0.4 0.4 47 5 38 305 9 0 9 0 -13.9 0 -13.5 -14.1 01/27/2005 15:50:00 12.1 1.1 14.9 9.1 11.9 1.2 15.3 8.8 0.4 0 0.4 0.4 45 6 31 305 9 0 9 0 -13.9 0.1 -13.5 -14.1 01/27/2005 16:00:00 13.6 1.1 16.8 10.3 13.5 1.2 16.4 9.9 0.4 0 0.4 0.4 46 5 46 305 9 0 9 0 -13.8 0 -13.5 -14.1 01/27/2005 16:10:00 13 1.1 16.1 10.3 12.9 1.2 16.1 9.9 0.4 0 0.4 0.4 44 5 35 305 9 0 9 0 -13.8 0 -13.3 -14.1 01/27/2005 16:20:00 13.1 1.3 16.4 9.9 12.9 1.3 16.1 9.1 0.4 0 0.4 0.4 45 6 46 305 9 0 9 0 -13.9 0.1 -13.5 -14.1 01/27/2005 16:30:00 13 1.2 16.4 10.3 12.8 1.3 16.1 9.5 0.4 0 0.4 0.4 44 5 42 305 9 0 9 0 -14.1 0.1 -13.7 -14.3 01/27/2005 16:40:00 13.9 1.1 16.4 11.1 13.7 1.2 16.8 10.7 0.4 0 0.4 0.4 45 5 40 305 9 0 9 0 -14 0.1 -13.7 -14.3 01/27/2005 16:50:00 12.7 1.3 15.6 9.5 12.5 1.4 15.6 9.1 0.4 0 0.4 0.4 45 5 46 305 9 0 9 0 -14 0.1 -13.7 -14.3 01/27/2005 17:00:00 13.1 1.1 16.1 10.7 13 1.1 16.1 10.3 0.4 0 0.4 0.4 44 5 38 305 9 0 9 0 -14 0.1 -13.5 -14.3 01/27/2005 17:10:00 13.2 1.5 16.4 10.3 13.1 1.5 16.1 10.3 0.4 0 0.4 0.4 42 5 45 305 8 0 8 0 -14 0.1 -13.7 -14.3 01/27/2005 17:20:00 11.8 1 14.5 9.1 11.6 1 14.5 8.4 0.4 0 0.4 0.4 42 5 38 305 8 0 8 0 -14.1 0 -13.7 -14.3 01/27/2005 17:30:00 12.8 1.2 16.1 10.3 12.7 1.2 15.6 10.3 0.4 0 0.4 0.4 43 5 35 305 8 0 8 0 -14.2 0 -13.7 -14.3 01/27/2005 17:40:00 12.5 1.1 14.9 8.8 12.4 1.3 15.3 8.8 0.4 0 0.4 0.4 41 5 36 305 8 0 8 0 -14.3 0.1 -13.7 -14.6 01/27/2005 17:50:00 12.2 1 14.9 9.1 12.1 1.1 14.9 9.5 0.4 0 0.4 0.4 43 5 47 305 7 0 7 0 -14.4 0 -13.9 -14.4 01/27/2005 18:00:00 12.4 0.9 15.6 9.9 12.2 1 14.9 9.5 0.4 0 0.4 0.4 43 5 37 305 7 0 7 0 -14.2 0 -13.9 -14.4 01/27/2005 18:10:00 12.3 1 14.5 9.5 12 1.1 14.5 8.8 0.4 0 0.4 0.4 42 5 45 305 8 0 7 0 -14.3 0 -14.3 -14.4 01/27/2005 18:20:00 12.3 1 14.9 9.9 12 1 14.5 9.5 0.4 0 0.4 0.4 41 5 33 305 7 0 7 0 -14.4 0 -14.3 -14.6 01/27/2005 18:30:00 11.9 1.2 14.5 9.1 11.6 1.2 14.5 8.8 0.4 0 0.4 0.4 42 5 49 305 7 0 7 0 -14.4 0 -14.1 -14.6 01/27/2005 18:40:00 11.5 1.2 14.1 8.4 11.3 1.2 14.5 8.4 0.4 0 0.4 0.4 39 5 40 305 7 0 7 0 -14.4 0 -14.3 -14.6 01/27/2005 18:50:00 11.8 0.9 14.1 9.1 11.6 1 14.1 9.1 0.4 0 0.4 0.4 38 5 41 305 7 0 7 0 -14.4 0 -14.3 -14.6 01/27/2005 19:00:00 11.8 1.1 14.5 9.1 11.6 1.1 14.5 8.8 0.4 0 0.4 0.4 41 5 40 305 7 0 7 0 -14.6 0 -14.3 -14.6 01/27/2005 19:10:00 12.1 1 15.3 9.1 11.9 1.1 14.9 9.1 0.4 0 0.4 0.4 39 6 39 305 7 0 7 0 -14.7 0 -14.4 -14.6 01/27/2005 19:20:00 12.5 1.3 15.6 9.5 12.2 1.4 15.6 8.8 0.4 0 0.4 0.4 38 5 36 305 7 0 7 0 -14.7 0 -14.4 -14.6 01/27/2005 19:30:00 12.7 1.2 15.3 8.8 12.4 1.3 15.3 9.1 0.4 0 0.4 0.4 36 6 42 305 8 0 8 0 -14.6 0.1 -14.3 -14.6 01/27/2005 19:40:00 11.4 1.2 14.5 8.4 11.1 1.2 14.1 8.4 0.4 0 0.4 0.4 34 6 35 305 8 0 7 0 -14.7 0 -14.4 -14.6 01/27/2005 19:50:00 11.5 1.3 14.5 8 11.3 1.3 14.5 7.6 0.4 0 0.4 0.4 33 5 33 305 7 0 7 0 -14.7 0 -14.6 -14.8 01/27/2005 20:00:00 11 1.2 14.5 8.4 10.8 1.2 14.5 8.4 0.4 0 0.4 0.4 36 6 33 305 7 0 7 0 -14.8 0 -14.3 -15 01/27/2005 20:10:00 10.5 1 13 8 10.4 1 13 7.6 0.4 0 0.4 0.4 31 5 28 305 7 0 7 0 -14.8 0 -14.4 -14.8 01/27/2005 20:20:00 10.5 1.1 13 6.8 10.3 1.2 13.3 6.8 0.4 0 0.4 0.4 34 5 41 305 7 0 7 0 -14.9 0 -14.6 -15 01/27/2005 20:30:00 10.6 0.9 13 8.4 10.3 1 13 8 0.4 0 0.4 0.4 35 5 43 305 7 0 7 0 -15.1 0 -14.8 -15.2 01/27/2005 20:40:00 10 0.8 12.6 8 9.8 0.8 12.2 7.6 0.4 0 0.4 0.4 33 5 30 305 7 0 7 0 -15 0 -14.6 -15.2 01/27/2005 20:50:00 9.8 1 13 7.6 9.6 1 13 7.2 0.4 0 0.4 0.4 33 5 34 305 7 0 7 0 -14.9 0 -14.6 -15 01/27/2005 21:00:00 9.5 0.8 11.8 7.6 9.2 0.8 11.5 7.6 0.4 0 0.4 0.4 34 6 32 305 7 0 7 0 -15 0 -14.6 -15 01/27/2005 21:10:00 9.9 1 13.3 7.6 9.6 1 13 7.2 0.4 0 0.4 0.4 32 6 27 305 7 0 7 0 -15.1 0.1 -14.6 -15.2 01/27/2005 21:20:00 11.7 1.3 14.5 8.4 11.5 1.3 14.5 8 0.4 0 0.4 0.4 37 5 34 305 7 0 7 0 -15.1 0.1 -14.6 -15.2 01/27/2005 21:30:00 11.6 1.3 15.3 8.8 11.5 1.3 15.6 8.8 0.4 0 0.4 0.4 36 5 35 305 7 0 7 0 -15.1 0.1 -14.6 -15.2 01/27/2005 21:40:00 11.5 1.1 13.7 8.8 11.3 1.1 13.7 8.4 0.4 0 0.4 0.4 33 6 29 305 7 0 7 0 -15.1 0.1 -14.6 -15.2 01/27/2005 21:50:00 11.5 1.2 14.9 8.8 11.3 1.2 14.5 8.4 0.4 0 0.4 0.4 36 6 36 305 7 0 7 0 -15.2 0 -14.8 -15.4 01/27/2005 22:00:00 11.4 1 13.7 9.1 11.2 1.2 13.7 8.4 0.4 0 0.4 0.4 35 7 39 305 7 0 7 0 -15.3 0 -15 -15.6 01/27/2005 22:10:00 11.1 1.4 14.9 8 10.8 1.4 14.5 7.6 0.4 0 0.4 0.4 34 6 33 305 7 0 7 0 -15.3 0 -15 -15.6 01/27/2005 22:20:00 11.6 1.5 15.3 8.4 11.4 1.5 14.9 8.8 0.4 0 0.4 0.4 31 6 29 305 7 0 7 0 -15.4 0 -15 -15.6 01/27/2005 22:30:00 12.7 1.5 15.6 9.1 12.4 1.4 15.6 9.1 0.4 0 0.4 0.4 31 5 30 305 7 0 7 0 -15.5 0 -15 -15.6 01/27/2005 22:40:00 12 1.3 15.6 8.8 11.7 1.2 15.6 8.4 0.4 0 0.4 0.4 35 6 31 305 7 0 7 0 -15.6 0.1 -15.2 -15.8 01/27/2005 22:50:00 12.4 1.3 15.6 9.1 12.2 1.3 15.3 9.1 0.4 0 0.4 0.4 37 6 21 305 7 0 7 0 -15.8 0 -15.6 -16 01/27/2005 23:00:00 13.3 1.4 16.4 9.5 12.9 1.5 16.8 9.5 0.4 0 0.4 0.4 33 6 36 305 7 0 7 0 -15.8 0 -15.4 -16 01/27/2005 23:10:00 13.2 1.7 17.6 9.5 12.9 1.7 17.9 8.8 0.4 0 0.4 0.4 31 6 22 305 7 0 7 0 -15.8 0 -15.6 -16 01/27/2005 23:20:00 13 1.4 16.1 9.5 12.8 1.4 15.6 9.1 0.4 0 0.4 0.4 28 6 39 305 7 0 7 0 -15.9 0 -15.8 -16 01/27/2005 23:30:00 13.2 1.3 16.8 9.9 12.7 1.5 16.8 8 0.4 0 0.4 0.4 31 5 33 305 7 0 7 0 -15.9 0 -15.8 -16 01/27/2005 23:40:00 13.2 1.3 17.9 10.3 13.1 1.5 17.2 9.9 0.4 0 0.4 0.4 32 5 41 305 7 0 7 0 -15.9 0 -15.8 -16 01/27/2005 23:50:00 12.1 1.3 15.3 8.8 11.9 1.3 15.3 8.8 0.4 0 0.4 0.4 28 5 32 305 7 0 7 0 -15.9 0 -15.8 -16 01/28/2005 00:00:00 12.1 1.1 14.9 9.5 11.9 1.1 14.5 9.5 0.4 0 0.4 0.4 29 6 27 305 7 0 6 0 -16 0 -15.8 -16.2 01/28/2005 00:10:00 12.6 1.4 16.8 9.5 12.3 1.5 17.2 8.8 0.4 0 0.4 0.4 29 5 33 305 7 0 7 0 -16 0 -15.8 -16.2 01/28/2005 00:20:00 11.3 1.4 14.5 8.4 11.2 1.3 14.5 8.4 0.4 0 0.4 0.4 28 5 32 305 6 0 7 0 -16.1 0 -15.8 -16.4 01/28/2005 00:30:00 11.5 0.9 14.1 8.8 11.3 1 13.7 8 0.4 0 0.4 0.4 27 5 21 305 6 0 6 0 -16.3 0 -16.2 -16.6 01/28/2005 00:40:00 11.2 1.2 14.5 8.4 10.9 1.2 14.5 8 0.4 0 0.4 0.4 27 5 24 305 6 0 6 0 -16.4 0 -16 -16.6 01/28/2005 00:50:00 10.5 1.2 13.3 7.6 10.2 1.1 13.3 7.2 0.4 0 0.4 0.4 26 6 15 305 6 0 6 0 -16.4 0 -16.2 -16.6 01/28/2005 01:00:00 10.9 1.1 13.3 8.4 10.7 1.2 13.3 7.6 0.4 0 0.4 0.4 27 5 24 305 6 0 6 0 -16.4 0 -16.2 -16.7 01/28/2005 01:10:00 11.8 1.2 14.1 8.8 11.6 1.2 14.1 8.4 0.4 0 0.4 0.4 23 5 23 305 6 0 6 0 -16.5 0 -16.4 -16.6 01/28/2005 01:20:00 11.5 0.9 14.1 8.8 11.2 0.9 13.3 8.4 0.4 0 0.4 0.4 24 5 29 305 6 0 6 0 -16.6 0 -16.4 -16.7 01/28/2005 01:30:00 10.7 1 13 8.4 10.4 1.1 13 7.6 0.4 0 0.4 0.4 23 6 19 305 6 0 6 0 -16.7 0.1 -16.4 -16.9 01/28/2005 01:40:00 10.1 1.1 13.3 7.2 10 1.1 13.3 7.6 0.4 0 0.4 0.4 25 6 20 305 6 0 6 0 -16.7 0 -16.6 -16.9 01/28/2005 01:50:00 10.2 1 12.6 7.6 10 0.9 12.6 7.6 0.4 0 0.4 0.4 26 6 30 305 6 0 6 0 -16.7 0 -16.6 -16.9 01/28/2005 02:00:00 10.5 1.1 13.3 7.6 10.2 1.1 13 7.6 0.4 0 0.4 0.4 27 6 21 305 6 0 6 0 -16.7 0 -16.4 -16.9 01/28/2005 02:10:00 10.6 1.1 13.3 8 10.3 1.1 13.7 7.2 0.4 0 0.4 0.4 27 5 27 305 6 0 6 0 -16.7 0 -16.4 -16.9 01/28/2005 02:20:00 10.7 1 13.3 8.4 10.5 1 13.3 8.4 0.4 0 0.4 0.4 25 5 22 305 6 0 6 0 -16.8 0.1 -16.4 -16.9 01/28/2005 02:30:00 10.8 1.1 14.5 8 10.6 1.1 13.7 8 0.4 0 0.4 0.4 27 6 26 305 6 0 6 0 -16.7 0.1 -16.6 -16.9 01/28/2005 02:40:00 11.3 1 14.5 8.8 11 1 13 8.8 0.4 0 0.4 0.4 27 6 14 305 6 0 6 0 -16.7 0.1 -16.6 -16.9 01/28/2005 02:50:00 11.9 1.1 14.5 9.1 11.7 1.1 14.9 8.8 0.4 0 0.4 0.4 27 6 23 305 6 0 6 0 -16.7 0.1 -16.4 -16.9 01/28/2005 03:00:00 11.6 1.1 14.9 8.8 11.4 1.1 14.5 8.4 0.4 0 0.4 0.4 30 6 30 305 6 0 6 0 -16.7 0 -16.4 -16.9 01/28/2005 03:10:00 11.2 1.2 14.1 8.4 10.9 1.2 14.5 8 0.4 0 0.4 0.4 30 6 35 305 6 0 6 0 -16.6 0 -16.4 -16.9 01/28/2005 03:20:00 12.2 1.1 14.9 9.5 11.9 1.2 14.9 8.8 0.4 0 0.4 0.4 28 6 25 305 6 0 6 0 -16.6 0 -16.6 -16.9 01/28/2005 03:30:00 11.6 1.4 15.3 8.8 11.3 1.4 15.3 8.4 0.4 0 0.4 0.4 26 6 23 305 6 0 6 0 -16.6 0 -16.4 -16.9 01/28/2005 03:40:00 11.9 1.2 15.3 9.1 11.7 1.2 14.5 8.8 0.4 0 0.4 0.4 28 5 29 305 6 0 6 0 -16.4 0 -16.4 -16.6 01/28/2005 03:50:00 12.1 1.1 14.9 9.1 11.9 1.2 14.5 8.8 0.4 0 0.4 0.4 27 5 33 305 6 0 6 0 -16.5 0 -16.4 -16.6 01/28/2005 04:00:00 12.9 1.2 15.6 9.9 12.6 1.2 15.6 9.1 0.4 0 0.4 0.4 25 6 17 305 6 0 6 0 -16.4 0 -16 -16.6 01/28/2005 04:10:00 12 1.2 15.6 8.8 11.9 1.3 14.9 9.1 0.4 0 0.4 0.4 26 6 25 305 6 0 6 0 -16.5 0 -16.2 -16.6 01/28/2005 04:20:00 12.5 1.3 15.3 9.5 12.3 1.5 15.6 9.1 0.4 0 0.4 0.4 26 6 20 305 6 0 6 0 -16.4 0 -16.2 -16.6 01/28/2005 04:30:00 13.4 1.1 16.4 10.7 13.2 1.2 16.4 10.3 0.4 0 0.4 0.4 27 5 28 305 6 0 6 0 -16.5 0 -16.2 -16.7 01/28/2005 04:40:00 13.1 1.7 16.4 9.9 12.9 1.7 16.8 9.1 0.4 0 0.4 0.4 29 5 30 305 6 0 6 0 -16.5 0 -16.2 -16.7 01/28/2005 04:50:00 13 1.3 16.4 9.9 12.8 1.3 15.6 9.1 0.4 0 0.4 0.4 29 5 29 305 6 0 6 0 -16.5 0 -16.2 -16.6 01/28/2005 05:00:00 12.9 1.1 16.1 9.9 12.6 1.2 15.6 9.1 0.4 0 0.4 0.4 29 5 29 305 6 0 6 0 -16.5 0 -16.4 -16.6 01/28/2005 05:10:00 12.6 1.2 15.6 9.1 12.4 1.2 15.3 8.8 0.4 0 0.4 0.4 27 5 28 305 6 0 6 0 -16.5 0 -16.4 -16.6 01/28/2005 05:20:00 13.2 1.2 16.1 9.5 12.9 1.3 16.4 9.1 0.4 0 0.4 0.4 30 5 26 305 6 0 6 0 -16.6 0 -16.4 -16.7 01/28/2005 05:30:00 12.6 1.2 16.1 9.9 12.3 1.3 16.1 9.1 0.4 0 0.4 0.4 31 5 32 305 6 0 6 0 -16.5 0 -16.2 -16.6 01/28/2005 05:40:00 11.8 1 14.9 8.8 11.6 1.1 14.1 8.4 0.4 0 0.4 0.4 29 5 34 305 6 0 6 0 -16.4 0 -16.2 -16.6 01/28/2005 05:50:00 11.1 1.2 13.7 8 10.9 1.2 13.7 8 0.4 0 0.4 0.4 24 5 31 305 6 0 6 0 -16.4 0 -16 -16.6 01/28/2005 06:00:00 11.7 1.1 14.1 8.8 11.5 1.2 14.5 8 0.4 0 0.4 0.4 30 5 33 305 6 0 6 0 -16.4 0 -16 -16.6 01/28/2005 06:10:00 11.8 1.2 14.1 8.8 11.6 1.2 14.1 8.4 0.4 0 0.4 0.4 32 5 27 305 6 0 6 0 -16.4 0 -16 -16.6 01/28/2005 06:20:00 11.5 1 13.7 8.8 11.2 1 14.1 8.8 0.4 0 0.4 0.4 35 5 40 305 6 0 6 0 -16.5 0 -16.2 -16.6 01/28/2005 06:30:00 11.9 1.1 15.3 9.1 11.7 1 14.5 9.5 0.4 0 0.4 0.4 33 6 39 305 6 0 6 0 -16.4 0 -16 -16.6 01/28/2005 06:40:00 12.5 1.2 16.1 9.9 12.2 1.2 15.6 8.8 0.4 0 0.4 0.4 35 6 31 305 6 0 6 0 -16.2 0.1 -15.8 -16.4 01/28/2005 06:50:00 12.2 1.1 14.5 9.1 11.9 1.1 14.1 9.1 0.4 0 0.4 0.4 29 5 40 305 6 0 6 0 -16.3 0.1 -15.8 -16.4 01/28/2005 07:00:00 11.6 1.2 14.5 8.8 11.3 1.1 14.1 7.6 0.4 0 0.4 0.4 28 6 23 305 6 0 6 0 -16.3 0 -16 -16.6 01/28/2005 07:10:00 11.3 1.3 14.5 8.4 11 1.4 14.1 8.4 0.4 0 0.4 0.4 29 6 30 305 6 0 6 0 -16.4 0 -16 -16.6 01/28/2005 07:20:00 11.3 1.2 14.5 8.4 11.2 1.2 14.1 8 0.4 0 0.4 0.4 36 6 35 305 6 0 6 0 -16.4 0 -16 -16.6 01/28/2005 07:30:00 12.8 1.2 16.1 9.5 12.6 1.3 16.1 9.5 0.4 0 0.4 0.4 35 5 31 305 6 0 6 0 -16.5 0 -16.2 -16.6 01/28/2005 07:40:00 13.5 1.2 16.8 9.9 13.2 1.3 16.8 9.9 0.4 0 0.4 0.4 30 5 29 305 6 0 6 0 -16.5 0 -16.4 -16.6 01/28/2005 07:50:00 13.2 1.3 16.4 9.9 12.9 1.4 16.4 9.1 0.4 0 0.4 0.4 34 6 28 305 6 0 6 0 -16.5 0 -16.4 -16.6 01/28/2005 08:00:00 12.2 1 14.9 9.5 11.9 1.1 14.9 9.1 0.4 0 0.4 0.4 35 6 34 305 6 0 6 0 -16.6 0 -16.2 -16.7 01/28/2005 08:10:00 11 1.2 13.7 8 10.7 1.3 13.7 7.2 0.4 0 0.4 0.4 31 6 37 305 6 0 6 0 -16.5 0 -16.2 -16.6 01/28/2005 08:20:00 11.8 1.5 15.3 8 11.5 1.5 15.3 8.4 0.4 0 0.4 0.4 31 6 33 305 6 0 6 0 -16.4 0 -16.2 -16.6 01/28/2005 08:30:00 11.8 1.2 15.3 8.8 11.6 1.2 14.5 8.8 0.4 0 0.4 0.4 27 6 31 305 6 0 6 0 -16.4 0 -16.2 -16.6 01/28/2005 08:40:00 11.4 1.3 14.1 8.4 11.2 1.3 14.9 7.6 0.4 0 0.4 0.4 25 5 28 305 6 0 6 0 -16.5 0 -16 -16.7 01/28/2005 08:50:00 12.2 1.1 15.6 9.5 11.9 1.1 14.5 8.8 0.4 0 0.4 0.4 25 6 21 305 6 0 6 0 -16.6 0 -16.4 -16.7 01/28/2005 09:00:00 12.5 1.2 15.3 9.5 12.4 1.2 15.3 9.1 0.4 0 0.4 0.4 23 6 24 305 6 0 6 0 -16.5 0 -16.4 -16.6 01/28/2005 09:10:00 12.7 1.2 15.6 9.5 12.6 1.1 15.3 9.5 0.4 0 0.4 0.4 26 5 24 305 6 0 6 0 -16.7 0 -16.4 -16.9 01/28/2005 09:20:00 11.8 1 14.9 9.1 11.4 1.2 15.6 8.8 0.4 0 0.4 0.4 30 5 20 305 6 0 6 0 -16.8 0 -16.6 -16.9 01/28/2005 09:30:00 12.2 1.1 15.6 9.1 11.7 1.1 15.3 9.1 0.4 0 0.4 0.4 29 5 23 305 5 0 6 0 -16.8 0 -16.6 -16.9 01/28/2005 09:40:00 12.4 1 14.9 9.5 11.9 1.1 14.5 8.8 0.4 0 0.4 0.4 30 5 33 305 5 0 5 0 -16.7 0.1 -16.6 -16.9 01/28/2005 09:50:00 11.7 1.1 14.5 8.4 11.4 1.2 15.3 8.4 0.4 0 0.4 0.4 29 6 28 305 5 0 5 0 -16.7 0 -16.6 -16.9 01/28/2005 10:00:00 11.4 1.3 15.6 8.4 11.2 1.5 16.1 8 0.4 0 0.4 0.4 32 5 29 305 5 0 5 0 -16.7 0.1 -16.4 -16.9 01/28/2005 10:10:00 12.5 1.3 15.3 9.1 12.2 1.3 15.3 8.8 0.4 0 0.4 0.4 33 5 50 305 5 0 6 0 -16.5 0 -16.2 -16.6 01/28/2005 10:20:00 10.7 1.3 14.5 6.8 10.3 1.3 14.1 6.8 0.4 0 0.4 0.4 32 7 29 305 5 0 5 0 -16.7 0 -16.4 -16.9 01/28/2005 10:30:00 10.9 1.2 14.5 8 10.7 1.2 13.7 8 0.4 0 0.4 0.4 33 7 43 305 5 0 5 0 -16.7 0 -16.4 -16.9 01/28/2005 10:40:00 10.2 1.1 13.7 7.6 9.9 1.1 12.6 7.2 0.4 0 0.4 0.4 32 6 40 305 5 0 5 0 -16.8 0.1 -16.4 -16.9 01/28/2005 10:50:00 9.5 1 12.6 6.5 9.2 1 12.2 6.5 0.4 0 0.4 0.4 31 7 27 305 5 0 5 0 -16.8 0 -16.6 -16.9 01/28/2005 11:00:00 10.1 1.2 13.7 7.6 9.9 1.1 13 7.6 0.4 0 0.4 0.4 32 5 27 305 5 0 5 0 -16.8 0 -16.6 -16.9 01/28/2005 11:10:00 9.9 1.5 14.5 6.8 9.7 1.5 14.9 6.8 0.4 0 0.4 0.4 33 6 25 305 5 0 5 0 -16.8 0 -16.6 -16.9 01/28/2005 11:20:00 10.4 1.1 13 7.6 10.1 1.1 12.6 7.6 0.4 0 0.4 0.4 33 6 27 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 11:30:00 10.6 1.1 13.7 8 10.3 1.2 14.1 7.2 0.4 0 0.4 0.4 28 6 34 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 11:40:00 10.6 1.1 13.7 8 10.4 1.1 13.3 7.6 0.4 0 0.4 0.4 29 6 22 305 5 0 5 0 -17.1 0 -16.9 -17.3 01/28/2005 11:50:00 10.3 1.1 13 7.6 9.9 1.1 13 7.6 0.4 0 0.4 0.4 28 5 31 305 5 0 5 0 -17.2 0 -16.9 -17.3 01/28/2005 12:00:00 11 1.1 14.5 8.4 10.7 1.2 13.7 8.4 0.4 0 0.4 0.4 30 5 25 305 5 0 5 0 -17.2 0 -16.9 -17.5 01/28/2005 12:10:00 11.6 1 14.5 8.4 11.3 1.1 14.9 8.4 0.4 0 0.4 0.4 28 5 28 305 5 0 5 0 -17.2 0.1 -16.9 -17.5 01/28/2005 12:20:00 12.2 1.4 16.1 9.1 11.8 1.3 15.3 9.1 0.4 0 0.4 0.4 30 5 37 305 5 0 5 0 -17.1 0 -16.9 -17.3 01/28/2005 12:30:00 13.2 1.1 16.1 10.3 12.8 1.1 16.1 10.3 0.4 0 0.4 0.4 31 5 19 305 5 0 5 0 -17 0 -16.9 -17.1 01/28/2005 12:40:00 13.8 1.3 17.9 11.5 13.5 1.3 17.6 10.7 0.4 0 0.4 0.4 31 6 36 305 5 0 5 0 -17 0 -16.9 -17.1 01/28/2005 12:50:00 13.9 1.3 17.2 10.7 13.5 1.3 16.4 10.7 0.4 0 0.4 0.4 32 5 29 305 5 0 5 0 -17 0 -16.9 -17.1 01/28/2005 13:00:00 13.7 1.2 17.2 10.3 13.3 1.2 17.2 10.3 0.4 0 0.4 0.4 29 5 25 305 5 0 6 0 -16.9 0 -16.6 -16.9 01/28/2005 13:10:00 13.7 1.1 16.8 10.7 13.4 1.1 16.4 10.3 0.4 0 0.4 0.4 29 5 24 305 6 0 6 0 -16.9 0 -16.6 -16.9 01/28/2005 13:20:00 13.3 1.3 16.8 9.5 13 1.3 17.2 9.5 0.4 0 0.4 0.4 29 5 27 305 6 0 6 0 -16.9 0 -16.6 -16.9 01/28/2005 13:30:00 12.9 1.3 17.9 10.3 12.6 1.3 16.8 9.5 0.4 0 0.4 0.4 28 5 20 305 6 0 6 0 -16.9 0 -16.9 -16.9 01/28/2005 13:40:00 12.5 1.4 16.1 9.9 12.2 1.4 15.6 9.9 0.4 0 0.4 0.4 29 5 24 305 6 0 6 0 -16.9 0 -16.9 -16.9 01/28/2005 13:50:00 12.3 1.4 15.6 8 11.8 1.4 15.6 8 0.4 0 0.4 0.4 29 5 19 305 6 0 6 0 -16.9 0 -16.6 -16.9 01/28/2005 14:00:00 12.5 1.3 15.6 9.5 12.3 1.3 15.3 9.1 0.4 0 0.4 0.4 30 5 29 305 6 0 6 0 -16.9 0 -16.6 -16.9 01/28/2005 14:10:00 11.4 1 14.1 9.1 11.1 1.1 13.7 8.4 0.4 0 0.4 0.4 30 6 30 305 6 0 6 0 -16.9 0 -16.9 -16.9 01/28/2005 14:20:00 11.2 1.2 15.3 8 10.8 1.2 14.1 8 0.4 0 0.4 0.4 26 5 30 305 5 0 5 0 -16.9 0 -16.9 -16.9 01/28/2005 14:30:00 10.8 1.1 14.1 8 10.6 1 14.1 8 0.4 0 0.4 0.4 25 5 27 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 14:40:00 11.5 1.1 14.1 8.8 11.3 1.1 13.7 8.8 0.4 0 0.4 0.4 25 6 19 305 5 0 5 0 -16.9 0 -16.4 -16.9 01/28/2005 14:50:00 12.1 1.3 16.4 9.1 11.9 1.3 16.1 8.8 0.4 0 0.4 0.4 24 5 26 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 15:00:00 12.2 1.3 14.9 9.1 12 1.3 14.5 8.8 0.4 0 0.4 0.4 26 6 24 305 5 0 5 0 -16.8 0 -16.4 -16.9 01/28/2005 15:10:00 12.5 1.2 15.6 9.1 12.3 1.2 15.6 9.1 0.4 0 0.4 0.4 24 6 21 305 5 0 5 0 -16.8 0.1 -16.4 -16.9 01/28/2005 15:20:00 12.3 1.3 15.6 8.8 12.1 1.3 16.1 8.8 0.4 0 0.4 0.4 24 5 30 305 5 0 6 0 -16.7 0.1 -16.4 -16.9 01/28/2005 15:30:00 11.6 1.1 15.3 8 11.4 1.1 14.5 8 0.4 0 0.4 0.4 25 5 26 305 6 0 6 0 -16.6 0 -16.2 -16.9 01/28/2005 15:40:00 12.1 1.3 14.9 8.8 11.8 1.3 14.9 8.8 0.4 0 0.4 0.4 21 5 13 305 6 0 6 0 -16.5 0 -16 -16.6 01/28/2005 15:50:00 11.9 1.2 15.3 8.4 11.6 1.2 14.9 8.4 0.4 0 0.4 0.4 24 6 21 305 6 0 6 0 -16.4 0 -16 -16.6 01/28/2005 16:00:00 11.6 1.3 16.1 9.1 11.4 1.2 15.3 8.8 0.4 0 0.4 0.4 25 6 17 305 6 0 6 0 -16.4 0 -16 -16.6 01/28/2005 16:10:00 14 1.3 17.6 11.1 13.7 1.4 17.6 10.7 0.4 0 0.4 0.4 23 6 27 305 6 0 6 0 -16.2 0.1 -15.8 -16.4 01/28/2005 16:20:00 13.1 1.3 16.1 9.1 12.8 1.3 15.6 9.5 0.4 0 0.4 0.4 20 5 7 305 6 0 6 0 -16.3 0.1 -15.8 -16.6 01/28/2005 16:30:00 12.4 1.2 16.1 9.1 12.1 1.2 15.6 8.8 0.4 0 0.4 0.4 24 5 21 305 6 0 6 0 -16.3 0 -16 -16.6 01/28/2005 16:40:00 13.7 1.6 17.9 9.5 13.4 1.5 17.9 9.5 0.4 0 0.4 0.4 24 6 25 305 6 0 6 0 -16.3 0.1 -15.8 -16.4 01/28/2005 16:50:00 15 1.4 18.7 10.7 14.7 1.5 18.3 10.3 0.4 0 0.4 0.4 23 5 18 305 6 0 6 0 -16.3 0 -16 -16.4 01/28/2005 17:00:00 14.2 1.3 17.6 11.1 13.8 1.3 17.9 10.3 0.4 0 0.4 0.4 21 5 21 305 6 0 6 0 -16.3 0 -16 -16.4 01/28/2005 17:10:00 13.9 1.3 17.6 10.3 13.6 1.4 17.2 10.3 0.4 0 0.4 0.4 22 6 16 305 6 0 6 0 -16.3 0 -16.2 -16.4 01/28/2005 17:20:00 13.9 1.4 17.9 10.3 13.5 1.3 17.6 9.9 0.4 0 0.4 0.4 23 5 20 305 6 0 6 0 -16.4 0 -16.2 -16.6 01/28/2005 17:30:00 13.3 1.5 17.2 9.5 13.1 1.5 17.6 9.1 0.4 0 0.4 0.4 24 6 18 305 6 0 6 0 -16.4 0 -16 -16.6 01/28/2005 17:40:00 13.3 1.3 17.2 9.9 13 1.4 16.8 9.9 0.4 0 0.4 0.4 25 6 19 305 5 0 5 0 -16.3 0 -16 -16.4 01/28/2005 17:50:00 14.5 1.5 17.9 11.1 14.1 1.5 17.9 10.7 0.4 0 0.4 0.4 26 5 28 305 5 0 5 0 -16.2 0.1 -15.8 -16.4 01/28/2005 18:00:00 14.7 1.2 17.9 11.5 14.6 1.3 17.9 10.7 0.4 0 0.4 0.4 24 5 23 305 5 0 5 0 -16.1 0 -15.8 -16.2 01/28/2005 18:10:00 14.8 1.3 18.3 11.5 14.4 1.3 17.9 11.1 0.4 0 0.4 0.4 24 5 25 305 5 0 5 0 -16.2 0 -15.8 -16.2 01/28/2005 18:20:00 14.5 1.8 18.7 9.1 14.2 1.7 18.3 9.9 0.4 0 0.4 0.4 25 5 24 305 5 0 5 0 -16.2 0 -16 -16.4 01/28/2005 18:30:00 14.3 1.7 17.9 9.5 14 1.7 17.6 9.1 0.4 0 0.4 0.4 25 6 23 305 5 0 5 0 -16.3 0 -16 -16.4 01/28/2005 18:40:00 14.9 1.5 18.7 11.5 14.6 1.4 18.3 11.1 0.4 0 0.4 0.4 26 5 26 305 5 0 5 0 -16.3 0 -16 -16.4 01/28/2005 18:50:00 15.9 2 20.2 11.5 15.6 2 20.6 11.8 0.4 0 0.4 0.4 22 4 20 305 5 0 5 0 -16.3 0 -16 -16.4 01/28/2005 19:00:00 15 1.4 18.3 10.7 14.7 1.6 18.7 10.3 0.4 0 0.4 0.4 22 5 23 305 5 0 5 0 -16.3 0 -16 -16.4 01/28/2005 19:10:00 14.6 1.3 17.6 11.5 14.3 1.4 17.6 10.7 0.4 0 0.4 0.4 25 5 32 305 5 0 5 0 -16.4 0 -16 -16.6 01/28/2005 19:20:00 14.6 1.3 18.3 11.1 14.4 1.3 17.6 10.3 0.4 0 0.4 0.4 24 5 17 305 5 0 5 0 -16.4 0 -16 -16.6 01/28/2005 19:30:00 15 1.5 18.3 10.7 14.7 1.6 19.1 9.9 0.4 0 0.4 0.4 23 6 24 305 5 0 5 0 -16.5 0 -16 -16.6 01/28/2005 19:40:00 14.1 1.8 18.7 10.3 13.7 1.7 17.9 9.1 0.4 0 0.4 0.4 25 7 27 305 5 0 5 0 -16.6 0.1 -16.2 -16.9 01/28/2005 19:50:00 14.8 1.7 19.1 10.7 14.5 1.9 18.7 9.5 0.4 0 0.4 0.4 24 6 18 305 5 0 5 0 -16.7 0.1 -16.4 -16.9 01/28/2005 20:00:00 15.6 1.7 20.6 10.7 15.5 1.6 19.5 11.5 0.4 0 0.4 0.4 24 6 21 305 5 0 5 0 -16.8 0.1 -16.4 -16.9 01/28/2005 20:10:00 15.1 1.9 19.1 10.3 14.8 1.9 19.5 10.3 0.4 0 0.4 0.4 22 6 19 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 20:20:00 14.9 1.7 18.7 11.1 14.7 1.7 19.1 10.3 0.4 0 0.4 0.4 23 6 27 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 20:30:00 15.8 1.7 20.2 11.5 15.4 1.7 19.1 11.1 0.4 0 0.4 0.4 22 5 17 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 20:40:00 16.3 1.7 20.2 11.8 16 1.9 20.2 11.1 0.4 0 0.4 0.4 21 5 16 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 20:50:00 14.9 1.7 20.2 11.1 14.6 1.7 19.9 11.1 0.4 0 0.4 0.4 23 6 16 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 21:00:00 15.1 2 20.2 9.9 14.8 2.1 19.9 9.5 0.4 0 0.4 0.4 24 6 23 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 21:10:00 14.2 1.7 17.9 9.5 13.8 1.7 17.6 9.5 0.4 0 0.4 0.4 25 6 18 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 21:20:00 13.7 1.6 18.3 10.3 13.5 1.6 18.3 10.3 0.4 0 0.4 0.4 25 6 23 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 21:30:00 15.2 1.7 19.1 11.5 15 1.7 19.5 11.1 0.4 0 0.4 0.4 26 6 27 305 5 0 5 0 -16.9 0 -16.9 -16.9 01/28/2005 21:40:00 14.4 1.6 17.9 10.3 14.1 1.6 18.3 10.7 0.4 0 0.4 0.4 26 6 24 305 5 0 5 0 -16.9 0 -16.9 -16.9 01/28/2005 21:50:00 13.7 1.7 18.3 9.9 13.5 1.7 17.9 9.5 0.4 0 0.4 0.4 27 6 27 305 5 0 6 0 -16.9 0 -16.9 -16.9 01/28/2005 22:00:00 14.5 1.4 17.9 11.1 14.2 1.5 18.7 11.1 0.4 0 0.4 0.4 28 6 36 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 22:10:00 13.8 1.3 17.2 10.3 13.4 1.4 16.4 9.9 0.4 0 0.4 0.4 28 5 21 305 5 0 5 0 -16.8 0 -16.6 -16.9 01/28/2005 22:20:00 14 1.2 17.2 11.1 13.6 1.2 17.2 10.7 0.4 0 0.4 0.4 28 5 25 305 5 0 5 0 -16.7 0 -16.6 -16.9 01/28/2005 22:30:00 14.5 1.2 17.9 11.5 14.1 1.3 17.2 10.7 0.4 0 0.4 0.4 29 5 27 305 5 0 5 0 -16.6 0 -16.4 -16.9 01/28/2005 22:40:00 15.3 1.5 19.1 12.2 15 1.5 18.7 11.5 0.4 0 0.4 0.4 28 5 25 305 5 0 5 0 -16.6 0 -16.4 -16.7 01/28/2005 22:50:00 15.1 1.7 19.5 11.5 14.7 1.7 18.7 11.1 0.4 0 0.4 0.4 29 5 31 305 5 0 5 0 -16.7 0 -16.6 -16.9 01/28/2005 23:00:00 14.7 1.7 20.6 10.3 14.3 1.8 19.9 9.9 0.4 0 0.4 0.4 31 5 39 305 5 0 5 0 -16.7 0 -16.6 -16.9 01/28/2005 23:10:00 14.5 1.3 18.3 11.1 14.2 1.3 17.9 11.1 0.4 0 0.4 0.4 31 5 39 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 23:20:00 14.8 1.7 19.5 11.1 14.5 1.7 18.3 10.7 0.4 0 0.4 0.4 27 5 27 305 5 0 5 0 -16.9 0 -16.7 -16.9 01/28/2005 23:30:00 15.4 1.4 18.7 11.1 14.9 1.5 17.9 10.7 0.4 0 0.4 0.4 27 5 27 305 5 0 5 0 -16.9 0 -16.9 -16.9 01/28/2005 23:40:00 16.2 1.3 20.2 12.6 15.9 1.3 20.2 11.5 0.4 0 0.4 0.4 27 5 28 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/28/2005 23:50:00 15.3 1.3 19.1 12.6 14.8 1.3 17.9 11.8 0.4 0 0.4 0.4 28 5 38 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/29/2005 00:00:00 15.2 1.7 20.2 11.8 14.9 1.7 19.9 11.1 0.4 0 0.4 0.4 28 5 24 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/29/2005 00:10:00 16.2 1.5 20.2 12.6 15.6 1.5 19.5 12.2 0.4 0 0.4 0.4 27 5 33 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/29/2005 00:20:00 15.4 1.6 19.9 11.5 14.9 1.5 19.1 11.1 0.4 0 0.4 0.4 29 6 32 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/29/2005 00:30:00 14.6 1.6 18.7 10.3 14.2 1.5 17.9 10.7 0.4 0 0.4 0.4 30 6 21 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/29/2005 00:40:00 13.9 1.7 18.7 9.5 13.4 1.7 17.9 9.5 0.4 0 0.4 0.4 31 6 33 305 5 0 6 0 -16.9 0 -16.6 -16.9 01/29/2005 00:50:00 14.4 1.4 17.9 10.7 14 1.4 17.9 10.3 0.4 0 0.4 0.4 29 5 30 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/29/2005 01:00:00 14.6 1.7 19.5 10.3 14.2 1.7 19.1 11.1 0.4 0 0.4 0.4 29 6 25 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/29/2005 01:10:00 13.9 1.4 16.8 10.3 13.7 1.3 16.8 10.3 0.4 0 0.4 0.4 30 5 23 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/29/2005 01:20:00 14.9 1.3 19.1 11.5 14.3 1.2 18.3 11.5 0.4 0 0.4 0.4 31 5 27 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/29/2005 01:30:00 14 1.2 17.6 10.7 13.7 1.3 17.2 10.7 0.4 0 0.4 0.4 32 5 38 305 5 0 5 0 -16.9 0 -16.6 -16.9 01/29/2005 01:40:00 14.8 1.2 18.3 11.1 14.6 1.2 17.6 11.8 0.4 0 0.4 0.4 32 5 29 305 5 0 5 0 -16.8 0.1 -16.4 -16.9 01/29/2005 01:50:00 15.5 1.4 19.1 11.8 15.2 1.4 18.7 11.5 0.4 0 0.4 0.4 31 5 36 305 5 0 6 0 -16.7 0.1 -16.4 -16.9 01/29/2005 02:00:00 15.3 1.5 19.1 11.8 14.8 1.5 19.1 11.5 0.4 0 0.4 0.4 30 5 30 305 5 0 5 0 -16.7 0.1 -16.4 -16.9 01/29/2005 02:10:00 15 1.3 18.3 11.5 14.6 1.5 17.9 11.1 0.4 0 0.4 0.4 30 5 47 305 5 0 5 0 -16.8 0 -16.4 -16.9 01/29/2005 02:20:00 14.9 1.3 18.7 11.1 14.6 1.5 18.7 10.7 0.4 0 0.4 0.4 30 5 30 305 5 0 6 0 -16.8 0 -16.4 -16.9 01/29/2005 02:30:00 14.5 1.2 17.9 11.8 14.1 1.3 17.9 11.1 0.4 0 0.4 0.4 30 5 36 305 5 0 6 0 -16.9 0 -16.6 -16.9 01/29/2005 02:40:00 14.7 1.6 18.7 11.1 14.1 1.7 18.3 10.7 0.4 0 0.4 0.4 30 6 32 305 5 0 6 0 -16.9 0 -16.6 -16.9 01/29/2005 02:50:00 14.2 1.2 17.6 10.3 13.8 1.2 17.2 10.3 0.4 0 0.4 0.4 32 5 27 305 6 0 6 0 -16.7 0 -16.6 -16.9 01/29/2005 03:00:00 13.8 1.5 17.6 9.9 13.4 1.5 16.8 9.1 0.4 0 0.4 0.4 34 6 36 305 6 0 6 0 -16.7 0.1 -16.4 -16.9 01/29/2005 03:10:00 14.1 1.3 18.3 11.5 13.7 1.3 17.6 10.3 0.4 0 0.4 0.4 33 6 27 305 6 0 6 0 -16.7 0 -16.4 -16.9 01/29/2005 03:20:00 14.3 1.3 18.3 11.1 13.7 1.5 17.6 10.3 0.4 0 0.4 0.4 32 6 32 305 6 0 6 0 -16.7 0 -16.6 -16.9 01/29/2005 03:30:00 14.9 1.3 17.9 11.8 14.6 1.5 17.6 11.1 0.4 0 0.4 0.4 31 5 35 305 6 0 6 0 -16.7 0.1 -16.6 -16.9 01/29/2005 03:40:00 14.5 1.3 17.9 11.5 14.1 1.4 18.3 11.1 0.4 0 0.4 0.4 32 5 31 305 6 0 6 0 -16.7 0 -16.6 -16.9 01/29/2005 03:50:00 13.6 1.6 17.6 10.3 13.2 1.6 16.8 9.1 0.4 0 0.4 0.4 34 6 32 305 6 0 6 0 -16.7 0.1 -16.6 -16.9 01/29/2005 04:00:00 13 1.3 16.1 9.9 12.6 1.4 16.8 9.1 0.4 0 0.4 0.4 33 6 39 305 6 0 6 0 -16.6 0.1 -16.2 -16.9 01/29/2005 04:10:00 13 1.1 16.1 10.3 12.7 1.2 16.4 9.9 0.4 0 0.4 0.4 30 5 33 305 6 0 6 0 -16.5 0.1 -16 -16.9 01/29/2005 04:20:00 13.2 1 15.6 10.3 12.8 1.2 16.1 9.5 0.4 0 0.4 0.4 30 5 32 305 6 0 6 0 -16.7 0 -16.4 -16.9 01/29/2005 04:30:00 13.4 1.1 16.1 10.3 13.1 1.2 16.1 10.3 0.4 0 0.4 0.4 32 5 31 305 6 0 6 0 -16.5 0 -16.2 -16.9 01/29/2005 04:40:00 13.1 1.2 16.1 9.9 12.8 1.1 16.1 9.5 0.4 0 0.4 0.4 31 5 31 305 6 0 6 0 -16.6 0.1 -16.2 -16.9 01/29/2005 04:50:00 13.1 1.5 17.2 9.5 12.8 1.5 16.4 9.1 0.4 0 0.4 0.4 34 6 39 305 6 0 6 0 -16.6 0 -16.2 -16.7 01/29/2005 05:00:00 12.7 1.3 16.4 9.1 12.3 1.4 16.8 9.1 0.4 0 0.4 0.4 33 6 35 305 6 0 6 0 -16.6 0 -16.2 -16.9 01/29/2005 05:10:00 13.7 1.3 17.2 10.3 13.4 1.3 16.4 9.9 0.4 0 0.4 0.4 33 6 34 305 6 0 6 0 -16.6 0 -16.2 -16.9 01/29/2005 05:20:00 14.5 1.5 18.3 10.7 14.1 1.6 17.9 9.5 0.4 0 0.4 0.4 32 5 25 305 6 0 6 0 -16.6 0 -16.2 -16.9 01/29/2005 05:30:00 13.7 1.3 17.9 10.3 13.5 1.3 17.6 9.9 0.4 0 0.4 0.4 34 6 30 305 6 0 6 0 -16.5 0 -16.2 -16.6 01/29/2005 05:40:00 14.9 1.1 17.6 12.2 14.7 1.1 17.6 12.2 0.4 0 0.4 0.4 35 5 35 305 6 0 6 0 -16.5 0 -16 -16.6 01/29/2005 05:50:00 13.8 1.2 17.9 11.1 13.4 1.1 16.8 11.1 0.4 0 0.4 0.4 35 5 33 305 6 0 6 0 -16.5 0.1 -16 -16.6 01/29/2005 06:00:00 13.7 1.2 16.8 10.7 13.4 1.2 17.2 10.3 0.4 0 0.4 0.4 36 5 38 305 6 0 6 0 -16.3 0 -16 -16.6 01/29/2005 06:10:00 13.4 1 16.4 10.7 13.1 1 16.1 10.3 0.4 0 0.4 0.4 36 5 33 305 6 0 6 0 -16.2 0.1 -15.8 -16.4 01/29/2005 06:20:00 14 1.4 17.6 11.5 13.6 1.3 16.8 10.7 0.4 0 0.4 0.4 37 5 33 305 6 0 6 0 -16.2 0.1 -15.6 -16.4 01/29/2005 06:30:00 14.4 1.2 17.6 11.5 13.9 1.3 17.2 10.3 0.4 0 0.4 0.4 37 5 37 305 6 0 6 0 -16 0 -15.8 -16.2 01/29/2005 06:40:00 14.6 1.1 17.6 11.5 14 1.1 16.8 10.3 0.4 0 0.4 0.4 38 5 36 305 6 0 6 0 -16 0 -15.8 -16.2 01/29/2005 06:50:00 14.5 1 17.2 11.5 14.3 1 16.8 11.1 0.4 0 0.4 0.4 38 5 36 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 07:00:00 14.3 1.3 17.9 11.5 14 1.3 17.9 9.9 0.4 0 0.4 0.4 39 5 37 305 6 0 6 0 -15.8 0 -15.8 -16 01/29/2005 07:10:00 14.5 1.1 17.6 11.5 14.2 1.2 17.6 11.5 0.4 0 0.4 0.4 39 5 42 305 6 0 6 0 -15.8 0 -15.6 -16 01/29/2005 07:20:00 14.1 1.1 16.8 11.5 13.7 1.3 16.8 10.3 0.4 0 0.4 0.4 39 5 35 305 6 0 6 0 -15.9 0 -15.8 -16 01/29/2005 07:30:00 15 1.5 18.7 11.1 14.6 1.5 18.7 10.7 0.4 0 0.4 0.4 38 5 38 305 6 0 6 0 -16.1 0 -15.8 -16.2 01/29/2005 07:40:00 15.8 1.1 19.1 12.2 15.5 1.2 18.3 12.6 0.4 0 0.4 0.4 39 5 40 305 6 0 6 0 -16 0 -15.8 -16.2 01/29/2005 07:50:00 14.8 1 17.6 11.5 14.5 1.1 17.6 11.5 0.4 0 0.4 0.4 39 5 37 305 6 0 6 0 -16 0 -15.8 -16.2 01/29/2005 08:00:00 13.2 1.2 16.4 9.9 13 1.2 16.8 9.9 0.4 0 0.4 0.4 39 5 41 305 6 0 6 0 -15.9 0 -15.6 -16.2 01/29/2005 08:10:00 11.3 1.2 14.9 8.4 11.1 1.2 14.5 8 0.4 0 0.4 0.4 39 6 46 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 08:20:00 8.9 1.2 13.3 6.8 8.8 1.3 13.3 6.5 0.4 0 0.4 0.4 42 8 40 305 6 0 6 0 -16 0 -15.6 -16.2 01/29/2005 08:30:00 9.3 1.3 13 6.1 9.1 1.4 12.6 5.7 0.4 0 0.4 0.4 45 8 36 305 6 0 6 0 -16 0 -15.8 -16.2 01/29/2005 08:40:00 10.6 1.1 13.3 8 10.4 1.2 13.3 7.2 0.4 0 0.4 0.4 43 8 37 305 6 0 6 0 -15.9 0 -15.6 -16.2 01/29/2005 08:50:00 11.9 1.2 15.3 8 11.6 1.2 15.3 8 0.4 0 0.4 0.4 41 7 45 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 09:00:00 12.2 1.2 16.1 9.5 11.9 1.2 15.3 8.8 0.4 0 0.4 0.4 40 6 44 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 09:10:00 13.1 1.3 16.4 9.5 12.9 1.3 16.1 9.5 0.4 0 0.4 0.4 39 6 35 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 09:20:00 13.3 1.2 16.1 10.7 13 1.2 16.1 10.3 0.4 0 0.4 0.4 37 5 39 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 09:30:00 13 1 15.6 8.8 12.7 1 15.6 9.5 0.4 0 0.4 0.4 37 5 40 305 6 0 6 0 -15.9 0 -15.6 -16.2 01/29/2005 09:40:00 13.1 1.2 17.2 10.3 13 1.2 16.8 10.3 0.4 0 0.4 0.4 36 5 31 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 09:50:00 11.5 1 14.1 9.1 11.2 1 13.7 9.1 0.4 0 0.4 0.4 39 5 40 305 6 0 6 0 -15.9 0 -15.6 -16.2 01/29/2005 10:00:00 11.3 1.2 14.5 8.4 11.2 1.3 15.6 7.6 0.4 0 0.4 0.4 39 5 33 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 10:10:00 10 1 13 7.6 9.7 1 12.2 7.2 0.4 0 0.4 0.4 40 6 42 305 6 0 6 0 -16 0 -15.6 -16.2 01/29/2005 10:20:00 12 1.3 15.3 9.1 11.6 1.4 14.9 8.4 0.4 0 0.4 0.4 39 6 39 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 10:30:00 12.1 1.3 15.3 8.8 11.6 1.3 14.9 8.4 0.4 0 0.4 0.4 38 6 40 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 10:40:00 12.1 1.2 15.3 9.5 11.8 1.2 15.3 8.8 0.4 0 0.4 0.4 38 6 35 305 6 0 6 0 -15.8 0 -15.6 -16 01/29/2005 10:50:00 12.8 1.2 16.1 9.1 12.5 1.2 15.3 9.5 0.4 0 0.4 0.4 37 6 32 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 11:00:00 14.1 1 17.6 11.5 13.9 1.1 16.4 11.5 0.4 0 0.4 0.4 36 5 48 305 6 0 6 0 -15.8 0 -15.6 -16 01/29/2005 11:10:00 13.8 1 16.4 11.5 13.6 1.1 16.4 10.3 0.4 0 0.4 0.4 37 5 37 305 6 0 6 0 -15.9 0 -15.8 -16.2 01/29/2005 11:20:00 12.8 1 16.4 10.7 12.7 1 16.4 10.3 0.4 0 0.4 0.4 39 5 40 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 11:30:00 10.7 1.1 14.1 8 10.6 1.1 13.7 8 0.4 0 0.4 0.4 39 6 41 305 6 0 6 0 -15.9 0 -15.8 -16 01/29/2005 11:40:00 9.3 1.2 12.2 6.8 9.2 1.2 12.2 6.5 0.4 0 0.4 0.4 43 7 41 305 6 0 6 0 -15.9 0 -15.8 -16 01/29/2005 11:50:00 9 1 12.2 6.8 8.8 1 12.2 6.5 0.4 0 0.4 0.4 41 7 37 305 6 0 6 0 -15.9 0 -15.8 -16 01/29/2005 12:00:00 9.4 1.1 12.2 6.5 9.3 1.1 12.6 6.8 0.4 0 0.4 0.4 41 7 44 305 6 0 6 0 -15.9 0 -15.6 -16 01/29/2005 12:10:00 10.5 1 13.3 8.4 10.4 1 12.6 7.6 0.4 0 0.4 0.4 42 6 39 305 6 0 6 0 -15.8 0 -15.6 -16 01/29/2005 12:20:00 11.2 1.1 14.5 8.8 11 1 13.7 8.4 0.4 0 0.4 0.4 41 6 48 305 6 0 6 0 -15.8 0 -15.6 -16 01/29/2005 12:30:00 11.4 1 14.5 9.1 11.2 1.1 14.5 8 0.4 0 0.4 0.4 39 6 33 305 6 0 6 0 -15.8 0 -15.6 -15.8 01/29/2005 12:40:00 11.5 1 14.1 9.1 11.3 1 14.9 8.4 0.4 0 0.4 0.4 38 6 33 305 6 0 6 0 -15.7 0 -15.6 -15.8 01/29/2005 12:50:00 13 1.1 16.8 10.7 12.7 1.1 15.6 10.3 0.4 0 0.4 0.4 39 5 36 305 6 0 6 0 -15.6 0 -15.2 -15.8 01/29/2005 13:00:00 12.8 1.2 16.1 10.3 12.5 1.2 15.6 9.9 0.4 0 0.4 0.4 39 5 39 305 7 0 7 0 -15.4 0 -15 -15.6 01/29/2005 13:10:00 12.4 1 14.9 9.9 12.3 1.1 15.6 9.5 0.4 0 0.4 0.4 41 6 39 305 7 0 7 0 -15.3 0 -15 -15.6 01/29/2005 13:20:00 12.1 1.2 15.3 8.4 12 1.2 15.3 8.8 0.4 0 0.4 0.4 43 6 42 305 7 0 7 0 -15.3 0.1 -14.8 -15.6 01/29/2005 13:30:00 11.7 1.4 15.3 8.8 11.5 1.5 15.6 8.8 0.4 0 0.4 0.4 43 6 45 305 7 0 7 0 -15.3 0.1 -14.8 -15.4 01/29/2005 13:40:00 12.5 1.7 17.9 9.1 12.2 1.8 17.9 9.1 0.4 0 0.4 0.4 41 6 41 305 7 0 7 0 -15.2 0.1 -14.6 -15.2 01/29/2005 13:50:00 14 1.2 17.9 10.7 13.8 1.2 17.9 10.7 0.4 0 0.4 0.4 41 5 45 305 8 0 8 0 -15.1 0.1 -14.6 -15.2 01/29/2005 14:00:00 15.2 1.2 18.3 12.2 15.1 1.3 18.3 11.1 0.4 0 0.4 0.4 42 5 45 305 8 0 8 0 -15.1 0.1 -14.6 -15.2 01/29/2005 14:10:00 14.9 1.2 18.7 12.2 14.6 1.2 18.3 12.2 0.4 0 0.4 0.4 40 5 37 305 8 0 8 0 -15.1 0.1 -14.6 -15.2 01/29/2005 14:20:00 14.9 1.2 17.9 11.5 14.7 1.3 17.9 11.1 0.4 0 0.4 0.4 42 5 56 305 8 0 8 0 -15 0.1 -14.6 -15.2 01/29/2005 14:30:00 14.4 1.5 17.9 10.7 14.2 1.5 17.9 10.3 0.4 0 0.4 0.4 40 5 35 305 8 0 8 0 -14.9 0.1 -14.4 -15 01/29/2005 14:40:00 13.4 1 16.4 10.7 13.1 1.1 16.4 10.3 0.4 0 0.4 0.4 39 5 46 305 8 0 8 0 -15 0.1 -14.6 -15 01/29/2005 14:50:00 13.5 1.4 16.4 10.3 13.4 1.5 17.2 9.5 0.4 0 0.4 0.4 39 5 39 305 9 0 8 0 -15 0.1 -14.6 -15 01/29/2005 15:00:00 13.5 1.3 16.8 9.9 13.2 1.3 16.1 9.5 0.4 0 0.4 0.4 37 5 38 305 9 0 8 0 -15 0 -14.6 -15 01/29/2005 15:10:00 13.3 1.1 16.4 10.3 13.1 1.2 16.4 10.3 0.4 0 0.4 0.4 39 5 39 305 9 0 9 0 -15 0.1 -14.6 -15 01/29/2005 15:20:00 13.2 1.2 16.8 9.9 13 1.2 15.6 9.9 0.4 0 0.4 0.4 39 5 42 305 9 0 9 0 -14.9 0 -14.4 -15 01/29/2005 15:30:00 13.1 1.1 16.8 9.9 12.9 1.1 15.6 9.9 0.4 0 0.4 0.4 39 5 32 305 9 0 9 0 -14.9 0 -14.6 -15 01/29/2005 15:40:00 12.6 1.3 17.2 9.5 12.3 1.3 16.8 9.1 0.4 0 0.4 0.4 38 6 31 305 9 0 8 0 -14.8 0 -14.6 -15 01/29/2005 15:50:00 13.3 1.2 16.1 9.9 13 1.3 16.1 9.9 0.4 0 0.4 0.4 38 5 40 305 8 0 8 0 -14.8 0 -14.6 -15 01/29/2005 16:00:00 13.3 1 15.6 10.3 13.1 1.1 15.6 9.9 0.4 0 0.4 0.4 38 5 40 305 8 0 8 0 -14.7 0 -14.3 -15 01/29/2005 16:10:00 13 1.2 16.4 10.3 12.7 1.2 16.1 9.1 0.4 0 0.4 0.4 37 5 32 305 8 0 8 0 -14.7 0 -14.3 -14.8 01/29/2005 16:20:00 12.3 1.3 15.6 8.8 11.9 1.4 15.6 8.8 0.4 0 0.4 0.4 41 6 44 305 8 0 8 0 -14.7 0 -14.6 -14.8 01/29/2005 16:30:00 14.2 1.1 17.2 11.1 13.9 1.2 16.4 11.1 0.4 0 0.4 0.4 37 6 31 305 8 0 7 0 -14.7 0 -14.6 -14.8 01/29/2005 16:40:00 14 1.1 16.8 11.5 13.7 1.1 17.2 11.1 0.4 0 0.4 0.4 36 6 39 305 8 0 7 0 -14.7 0 -14.6 -14.8 01/29/2005 16:50:00 13.1 1.2 16.1 9.5 12.8 1.3 15.6 9.1 0.4 0 0.4 0.4 40 5 36 305 7 0 7 0 -14.7 0 -14.3 -14.8 01/29/2005 17:00:00 12.9 1.1 16.4 10.3 12.4 1.1 16.4 9.9 0.4 0 0.4 0.4 36 6 37 305 7 0 7 0 -14.7 0 -14.4 -14.8 01/29/2005 17:10:00 13.8 1 16.4 10.7 13.5 1 16.1 11.1 0.4 0 0.4 0.4 37 5 30 305 7 0 7 0 -14.7 0 -14.6 -14.8 01/29/2005 17:20:00 12.4 1.1 15.6 9.5 12.1 1.1 15.6 8.8 0.4 0 0.4 0.4 38 5 36 305 7 0 7 0 -14.8 0 -14.6 -15 01/29/2005 17:30:00 11.9 0.8 14.1 9.9 11.7 0.9 13.7 9.5 0.4 0 0.4 0.4 37 4 35 305 7 0 7 0 -14.9 0 -14.6 -15 01/29/2005 17:40:00 11.5 0.9 13.3 9.5 11.1 0.8 13.7 8.8 0.4 0 0.4 0.4 37 5 38 305 6 0 7 0 -15 0 -14.8 -15 01/29/2005 17:50:00 11.5 0.9 13.7 9.1 11.2 1 13.7 8.8 0.4 0 0.4 0.4 36 5 39 305 6 0 6 0 -15.1 0.1 -14.6 -15.2 01/29/2005 18:00:00 11.2 0.9 13.7 8.8 11 0.9 13.3 8.4 0.4 0 0.4 0.4 36 5 36 305 6 0 6 0 -15.1 0.1 -14.6 -15.2 01/29/2005 18:10:00 11 0.9 13 8.8 10.7 1 13 8 0.4 0 0.4 0.4 37 5 35 305 6 0 6 0 -15.1 0.1 -14.6 -15.2 01/29/2005 18:20:00 10.9 0.9 13.3 8.4 10.6 1 13.3 8.8 0.4 0 0.4 0.4 37 5 39 305 6 0 6 0 -15.1 0.1 -14.6 -15.2 01/29/2005 18:30:00 10.4 0.9 13.3 8 10.2 0.9 13 7.6 0.4 0 0.4 0.4 38 5 38 305 6 0 6 0 -15.1 0.1 -14.6 -15.2 01/29/2005 18:40:00 9.6 0.9 12.2 7.6 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 40 6 32 305 6 0 6 0 -15.1 0.1 -14.6 -15.2 01/29/2005 18:50:00 10.1 1.1 14.1 7.6 10 1.2 14.1 7.6 0.4 0 0.4 0.4 39 5 27 305 6 0 6 0 -15.1 0.1 -14.6 -15.2 01/29/2005 19:00:00 10.8 1.1 13.3 8.4 10.6 1.1 13.7 8.4 0.4 0 0.4 0.4 40 6 32 305 7 0 7 0 -15 0 -14.6 -15.2 01/29/2005 19:10:00 12.4 1.1 14.9 9.1 12.2 1.2 15.3 9.5 0.4 0 0.4 0.4 40 5 46 305 7 0 7 0 -14.9 0 -14.6 -15 01/29/2005 19:20:00 12.3 1 15.3 9.9 12.1 1 15.3 9.5 0.4 0 0.4 0.4 40 5 41 305 7 0 7 0 -14.9 0 -14.6 -15 01/29/2005 19:30:00 12 1 14.9 9.5 11.8 1 15.3 9.1 0.4 0 0.4 0.4 41 5 40 305 7 0 7 0 -14.9 0 -14.6 -15 01/29/2005 19:40:00 11 1 13.7 8.8 10.8 1.1 13.3 8 0.4 0 0.4 0.4 42 6 42 305 7 0 7 0 -14.9 0.1 -14.6 -15 01/29/2005 19:50:00 10.8 1.1 13.7 8 10.5 1.1 14.1 7.6 0.4 0 0.4 0.4 43 6 54 305 7 0 7 0 -15 0.1 -14.6 -15 01/29/2005 20:00:00 11 1.1 13.7 8.8 10.8 1.1 14.1 8.8 0.4 0 0.4 0.4 41 6 37 305 7 0 7 0 -14.9 0 -14.6 -15 01/29/2005 20:10:00 11 1 13.7 8.4 10.8 1.1 13.7 8 0.4 0 0.4 0.4 42 5 41 305 7 0 7 0 -14.9 0 -14.6 -15 01/29/2005 20:20:00 10.7 1 13.7 8.4 10.5 1 13.7 8.4 0.4 0 0.4 0.4 43 5 40 305 7 0 7 0 -15 0 -14.6 -15 01/29/2005 20:30:00 10.5 1 13 8 10.4 1.1 13 7.6 0.4 0 0.4 0.4 42 6 33 305 7 0 7 0 -15 0 -14.6 -15 01/29/2005 20:40:00 10.5 1 13.3 8.4 10.3 1.1 13.3 8 0.4 0 0.4 0.4 40 6 46 305 7 0 7 0 -14.9 0 -14.6 -15 01/29/2005 20:50:00 9.6 0.8 11.5 7.6 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 40 6 42 305 7 0 7 0 -15 0 -14.6 -15 01/29/2005 21:00:00 9.5 0.8 11.5 7.6 9.2 0.8 11.1 7.6 0.4 0 0.4 0.4 37 5 35 305 7 0 7 0 -15.1 0.1 -14.8 -15.2 01/29/2005 21:10:00 9.6 0.8 12.2 7.2 9.3 0.9 11.8 6.8 0.4 0 0.4 0.4 33 5 33 305 7 0 7 0 -15 0 -14.8 -15 01/29/2005 21:20:00 9.3 0.9 11.8 7.2 9.1 0.8 11.1 7.2 0.4 0 0.4 0.4 31 5 38 305 7 0 7 0 -15.1 0 -14.8 -15.2 01/29/2005 21:30:00 8.6 1 11.1 6.5 8.4 1 11.5 6.5 0.4 0 0.4 0.4 33 6 37 305 7 0 7 0 -15.1 0 -15 -15.2 01/29/2005 21:40:00 9.6 1 12.6 7.2 9.3 1 12.2 7.2 0.4 0 0.4 0.4 35 6 37 305 7 0 7 0 -15.1 0 -14.8 -15.2 01/29/2005 21:50:00 9.2 0.9 12.2 7.6 9 0.9 12.2 7.6 0.4 0 0.4 0.4 36 5 42 305 7 0 7 0 -15.1 0 -14.8 -15.2 01/29/2005 22:00:00 9.4 1 13 7.2 9.2 1 11.8 6.5 0.4 0 0.4 0.4 35 6 32 305 7 0 7 0 -15 0 -14.6 -15 01/29/2005 22:10:00 9.8 0.9 12.2 7.2 9.6 0.9 11.8 7.6 0.4 0 0.4 0.4 38 6 51 305 7 0 7 0 -14.9 0 -14.6 -15 01/29/2005 22:20:00 10.1 1.1 13 7.6 9.8 1 12.6 7.2 0.4 0 0.4 0.4 39 6 30 305 7 0 7 0 -14.8 0 -14.4 -15 01/29/2005 22:30:00 9.3 0.8 11.8 6.8 9.1 0.9 11.8 6.8 0.4 0 0.4 0.4 39 6 35 305 7 0 7 0 -14.8 0 -14.4 -15 01/29/2005 22:40:00 10 1.2 13 6.8 9.7 1.2 13.3 6.8 0.4 0 0.4 0.4 37 6 31 305 7 0 7 0 -14.7 0 -14.3 -14.8 01/29/2005 22:50:00 10.5 1.2 13 7.6 10.3 1.1 13 7.2 0.4 0 0.4 0.4 36 6 33 305 7 0 7 0 -14.7 0 -14.3 -14.8 01/29/2005 23:00:00 10 1.1 13.3 7.6 9.4 1.1 13 6.8 0.4 0 0.4 0.4 37 6 32 305 7 0 7 0 -14.7 0 -14.3 -14.8 01/29/2005 23:10:00 10.9 1.1 14.1 7.6 10.6 1.1 13.3 7.2 0.4 0 0.4 0.4 37 6 28 305 7 0 7 0 -14.7 0.1 -14.3 -14.8 01/29/2005 23:20:00 11.6 1 14.5 8.8 11.2 1.1 14.5 8.8 0.4 0 0.4 0.4 34 6 33 305 8 0 8 0 -14.6 0.1 -14.3 -14.6 01/29/2005 23:30:00 10.5 1 13 7.6 10.3 1.1 13 8 0.4 0 0.4 0.4 37 5 33 305 8 0 7 0 -14.6 0.1 -14.3 -14.6 01/29/2005 23:40:00 9.6 0.8 11.8 7.6 9.5 0.9 11.8 6.8 0.4 0 0.4 0.4 37 6 38 305 7 0 7 0 -14.7 0.1 -14.3 -14.6 01/29/2005 23:50:00 9.5 0.9 11.8 7.2 9.2 1 12.2 6.5 0.4 0 0.4 0.4 39 7 32 305 7 0 7 0 -14.7 0 -14.3 -14.8 01/30/2005 00:00:00 9.4 0.8 11.5 6.8 9.2 0.9 11.8 7.2 0.4 0 0.4 0.4 41 6 37 305 7 0 7 0 -14.7 0 -14.3 -14.6 01/30/2005 00:10:00 9.1 0.9 12.2 6.8 8.9 0.9 11.8 6.5 0.4 0 0.4 0.4 42 6 31 305 7 0 7 0 -14.7 0 -14.3 -14.8 01/30/2005 00:20:00 9.2 1 12.6 6.8 9 1 12.2 6.5 0.4 0 0.4 0.4 43 6 36 305 7 0 7 0 -14.7 0.1 -14.3 -14.8 01/30/2005 00:30:00 7.9 0.8 10.3 6.1 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 43 6 53 305 7 0 7 0 -14.7 0 -14.3 -14.8 01/30/2005 00:40:00 8.6 1.2 11.1 5.7 8.2 1.2 10.7 5.7 0.4 0 0.4 0.4 38 6 35 305 7 0 7 0 -14.6 0.1 -14.3 -14.8 01/30/2005 00:50:00 9 1.1 11.8 6.1 8.7 1.1 11.8 6.1 0.4 0 0.4 0.4 39 7 33 305 7 0 7 0 -14.6 0.1 -14.3 -14.8 01/30/2005 01:00:00 8.8 0.9 11.1 6.8 8.6 0.9 11.1 6.1 0.4 0 0.4 0.4 38 7 32 305 7 0 7 0 -14.6 0.1 -14.3 -14.8 01/30/2005 01:10:00 9.3 1 13 7.2 9 1 11.5 6.8 0.4 0 0.4 0.4 40 6 48 305 7 0 7 0 -14.5 0.1 -14.1 -14.6 01/30/2005 01:20:00 8.9 0.8 11.5 7.2 8.8 0.8 11.1 6.8 0.4 0 0.4 0.4 38 6 41 305 7 0 7 0 -14.5 0.1 -14.3 -14.6 01/30/2005 01:30:00 9 0.8 11.1 6.8 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 37 6 38 305 7 0 7 0 -14.5 0.1 -14.1 -14.6 01/30/2005 01:40:00 8.8 1 11.5 6.5 8.7 0.9 11.5 6.5 0.4 0 0.4 0.4 41 5 36 305 8 0 8 0 -14.5 0.1 -14.3 -14.6 01/30/2005 01:50:00 9.3 0.9 11.5 6.8 9.1 0.9 11.5 6.8 0.4 0 0.4 0.4 41 6 41 305 8 0 8 0 -14.4 0.1 -14.1 -14.6 01/30/2005 02:00:00 8.9 0.9 11.8 7.2 8.8 0.9 11.5 6.8 0.4 0 0.4 0.4 38 6 35 305 8 0 8 0 -14.4 0.1 -14.1 -14.6 01/30/2005 02:10:00 9.3 0.9 12.6 7.6 9.1 0.9 12.6 6.8 0.4 0 0.4 0.4 39 6 38 305 8 0 8 0 -14.4 0.1 -13.9 -14.6 01/30/2005 02:20:00 8.7 1 11.5 6.1 8.6 0.9 11.1 5.7 0.4 0 0.4 0.4 40 6 42 305 8 0 7 0 -14.5 0.2 -14.3 -14.6 01/30/2005 02:30:00 8.9 0.9 11.1 6.5 8.7 0.9 11.1 6.8 0.4 0 0.4 0.4 42 6 41 305 8 0 8 0 -14.5 0.1 -14.1 -14.6 01/30/2005 02:40:00 9 0.8 11.5 7.2 8.8 0.7 11.5 6.8 0.4 0 0.4 0.4 39 6 46 305 8 0 8 0 -14.4 0.1 -14.1 -14.6 01/30/2005 02:50:00 8.7 0.9 11.5 6.8 8.6 0.9 11.1 6.8 0.4 0 0.4 0.4 38 6 39 305 8 0 8 0 -14.4 0.1 -14.1 -14.6 01/30/2005 03:00:00 9.7 1 12.6 7.6 9.5 0.9 11.8 7.2 0.4 0 0.4 0.4 39 6 42 305 8 0 8 0 -14.4 0 -13.9 -14.6 01/30/2005 03:10:00 9.9 1 12.6 7.2 9.6 1 12.2 7.2 0.4 0 0.4 0.4 40 6 33 305 8 0 8 0 -14.3 0 -13.9 -14.6 01/30/2005 03:20:00 10 1 13 8 9.8 1 12.6 7.6 0.4 0 0.4 0.4 41 6 38 305 8 0 8 0 -14.3 0 -13.7 -14.4 01/30/2005 03:30:00 10.2 1 13.3 7.6 10 1.1 13 7.6 0.4 0 0.4 0.4 39 6 39 305 8 0 8 0 -14.3 0 -13.9 -14.4 01/30/2005 03:40:00 10.2 0.9 12.6 8.4 10.1 1 13.3 7.6 0.4 0 0.4 0.4 40 5 35 305 8 0 8 0 -14.3 0.1 -13.7 -14.4 01/30/2005 03:50:00 10.1 1.1 14.1 8 9.9 1 12.6 8 0.4 0 0.4 0.4 39 6 38 305 8 0 8 0 -14.2 0 -13.7 -14.4 01/30/2005 04:00:00 10.5 1 13 8 10.2 1 13 7.6 0.4 0 0.4 0.4 40 7 31 305 8 0 8 0 -14.3 0 -13.9 -14.4 01/30/2005 04:10:00 10.4 1.1 13 7.2 10.1 1 12.6 7.2 0.4 0 0.4 0.4 39 6 37 305 8 0 8 0 -14.3 0 -13.7 -14.4 01/30/2005 04:20:00 11 1 13.3 8.4 10.8 1 13.7 8 0.4 0 0.4 0.4 39 6 37 305 8 0 8 0 -14.3 0 -13.9 -14.4 01/30/2005 04:30:00 11.4 1 14.5 8.8 11.3 1 14.1 8.4 0.4 0 0.4 0.4 40 6 43 305 8 0 8 0 -14.3 0 -13.7 -14.4 01/30/2005 04:40:00 12.1 1 14.5 9.5 12 1.1 14.9 9.1 0.4 0 0.4 0.4 40 6 38 305 8 0 8 0 -14.3 0 -13.7 -14.4 01/30/2005 04:50:00 12.5 1.1 14.9 10.3 12.2 1.1 14.9 9.5 0.4 0 0.4 0.4 39 6 33 305 8 0 8 0 -14.2 0 -13.7 -14.3 01/30/2005 05:00:00 12.7 1.1 15.6 9.5 12.3 1.1 14.9 9.1 0.4 0 0.4 0.4 38 6 44 305 8 0 8 0 -14.2 0 -13.7 -14.3 01/30/2005 05:10:00 12.3 1 15.3 9.5 12 1 15.3 9.5 0.4 0 0.4 0.4 38 5 31 305 8 0 8 0 -14.2 0 -13.7 -14.3 01/30/2005 05:20:00 11.5 0.8 13.7 9.1 11.3 0.9 13.7 8.8 0.4 0 0.4 0.4 38 6 38 305 8 0 8 0 -14.2 0 -13.7 -14.4 01/30/2005 05:30:00 11.3 1 14.1 8.8 11.1 1.1 14.1 8.4 0.4 0 0.4 0.4 38 5 46 305 8 0 8 0 -14.3 0 -13.7 -14.4 01/30/2005 05:40:00 11.5 0.9 14.1 8 11.2 0.9 14.1 8.8 0.4 0 0.4 0.4 38 6 36 305 8 0 8 0 -14.3 0 -13.7 -14.4 01/30/2005 05:50:00 11.5 1 14.1 9.1 11.3 1.1 13.7 8.4 0.4 0 0.4 0.4 40 5 35 305 8 0 8 0 -14.3 0 -13.7 -14.4 01/30/2005 06:00:00 11.3 1 13.7 8.8 11.1 1 13.7 9.1 0.4 0 0.4 0.4 41 6 37 305 8 0 8 0 -14.3 0.1 -13.9 -14.4 01/30/2005 06:10:00 11.9 1 14.1 8.8 11.6 1.1 14.5 8 0.4 0 0.4 0.4 41 6 42 305 8 0 8 0 -14.3 0 -13.9 -14.4 01/30/2005 06:20:00 11.5 1 14.1 8.8 11.3 1 13.7 8.8 0.4 0 0.4 0.4 42 6 37 305 8 0 8 0 -14.3 0 -13.7 -14.4 01/30/2005 06:30:00 11.7 1 15.3 8.8 11.4 1.1 15.3 8.8 0.4 0 0.4 0.4 42 7 39 305 8 0 8 0 -14.3 0 -13.9 -14.4 01/30/2005 06:40:00 12.4 1 16.1 9.9 12.2 1.1 15.6 9.5 0.4 0 0.4 0.4 39 6 36 305 8 0 8 0 -14.3 0 -13.9 -14.4 01/30/2005 06:50:00 12.4 1.2 16.4 9.1 12.1 1.2 15.6 8.4 0.4 0 0.4 0.4 38 6 39 305 8 0 8 0 -14.2 0 -13.7 -14.3 01/30/2005 07:00:00 12.3 1 15.6 9.9 12 1 14.5 9.9 0.4 0 0.4 0.4 39 6 32 305 8 0 8 0 -14.2 0 -13.7 -14.4 01/30/2005 07:10:00 12.2 1 14.9 9.9 11.9 1.1 14.9 9.1 0.4 0 0.4 0.4 39 6 36 305 8 0 8 0 -14.2 0 -13.9 -14.3 01/30/2005 07:20:00 11.1 1 14.5 9.1 10.9 1 14.5 8.8 0.4 0 0.4 0.4 38 5 27 305 8 0 8 0 -14.2 0 -13.7 -14.4 01/30/2005 07:30:00 11.6 1 14.9 9.1 11.3 1 14.5 8.8 0.4 0 0.4 0.4 39 5 33 305 8 0 8 0 -14.2 0 -13.7 -14.4 01/30/2005 07:40:00 11.6 1 14.1 9.1 11.3 1 14.5 9.1 0.4 0 0.4 0.4 38 5 35 305 8 0 8 0 -14.2 0 -13.7 -14.3 01/30/2005 07:50:00 11.8 0.8 13.7 8.8 11.5 0.9 14.1 8 0.4 0 0.4 0.4 40 5 36 305 8 0 8 0 -14.1 0 -13.7 -14.3 01/30/2005 08:00:00 11.7 0.8 14.1 9.1 11.4 0.9 13.7 8.8 0.4 0 0.4 0.4 41 5 40 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 01/30/2005 08:10:00 11.8 0.9 14.1 9.5 11.5 1 14.5 9.1 0.4 0 0.4 0.4 40 5 43 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 01/30/2005 08:20:00 11.5 0.9 14.5 9.5 11.3 0.9 13.7 9.5 0.4 0 0.4 0.4 41 5 33 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 01/30/2005 08:30:00 11.5 1 14.5 9.1 11.3 1 13.7 8.8 0.4 0 0.4 0.4 42 5 44 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 01/30/2005 08:40:00 11.6 1 14.9 9.5 11.5 1 14.5 8.8 0.4 0 0.4 0.4 42 5 54 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 01/30/2005 08:50:00 11.1 0.8 13.3 8.8 10.9 0.8 13 8.8 0.4 0 0.4 0.4 42 5 41 305 8 0 8 0 -14.2 0 -13.7 -14.3 01/30/2005 09:00:00 11.4 0.9 13.7 9.1 11.1 1 14.1 8.4 0.4 0 0.4 0.4 42 5 45 305 8 0 8 0 -14.2 0 -13.7 -14.3 01/30/2005 09:10:00 11.3 1 13.7 9.1 11 1 13.3 8.8 0.4 0 0.4 0.4 43 5 43 305 8 0 8 0 -14.1 0 -13.7 -14.3 01/30/2005 09:20:00 11 0.8 13.3 8.8 10.8 0.8 13.3 8.4 0.4 0 0.4 0.4 43 5 33 305 8 0 8 0 -14.1 0 -13.7 -14.3 01/30/2005 09:30:00 10.6 0.8 13 8.4 10.3 0.9 13 8.4 0.4 0 0.4 0.4 44 5 49 305 8 0 8 0 -14.2 0 -13.7 -14.3 01/30/2005 09:40:00 10.7 0.8 13 8.8 10.4 0.9 13 8.4 0.4 0 0.4 0.4 44 5 42 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 01/30/2005 09:50:00 10.8 0.9 13.3 9.1 10.5 0.8 13 8.4 0.4 0 0.4 0.4 46 5 54 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 01/30/2005 10:00:00 10 0.8 12.2 8 9.7 0.8 11.8 8 0.4 0 0.4 0.4 48 5 46 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 01/30/2005 10:10:00 9.7 0.8 11.8 8 9.4 0.8 11.8 7.6 0.4 0 0.4 0.4 47 5 48 305 8 0 8 0 -14 0.1 -13.5 -14.3 01/30/2005 10:20:00 8.9 0.8 11.5 7.2 8.7 0.8 11.5 6.8 0.4 0 0.4 0.4 46 5 43 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 01/30/2005 10:30:00 8.5 0.7 10.7 6.8 8.4 0.7 11.5 6.8 0.4 0 0.4 0.4 46 5 51 305 8 0 8 0 -14.2 0.1 -13.7 -14.4 01/30/2005 10:40:00 8.5 0.8 11.1 6.5 8.3 0.8 10.7 6.5 0.4 0 0.4 0.4 44 5 41 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 01/30/2005 10:50:00 8.4 0.9 11.5 6.1 8.2 0.9 10.7 6.1 0.4 0 0.4 0.4 43 6 35 305 8 0 8 0 -14.3 0 -13.9 -14.4 01/30/2005 11:00:00 8.9 0.8 10.7 6.5 8.8 0.8 10.7 6.5 0.4 0 0.4 0.4 44 6 37 305 8 0 8 0 -14.4 0.1 -13.9 -14.6 01/30/2005 11:10:00 9.2 0.8 11.8 7.2 9 0.8 11.5 6.8 0.4 0 0.4 0.4 43 6 48 305 8 0 8 0 -14.5 0 -14.1 -14.6 01/30/2005 11:20:00 9.5 0.9 12.2 7.6 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 45 6 43 305 8 0 8 0 -14.5 0.1 -14.3 -14.6 01/30/2005 11:30:00 9.1 0.8 11.8 7.2 8.9 0.8 11.1 6.8 0.4 0 0.4 0.4 45 5 38 305 8 0 8 0 -14.5 0.1 -14.1 -14.6 01/30/2005 11:40:00 9.4 0.6 11.5 8 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 42 5 35 305 8 0 8 0 -14.5 0.1 -14.1 -14.6 01/30/2005 11:50:00 9 0.8 11.5 7.2 8.9 0.8 11.5 7.2 0.4 0 0.4 0.4 41 5 37 305 8 0 8 0 -14.5 0.1 -14.3 -14.6 01/30/2005 12:00:00 8.5 0.8 10.7 6.8 8.3 0.8 10.7 6.5 0.4 0 0.4 0.4 43 6 30 305 8 0 8 0 -14.4 0.1 -14.1 -14.6 01/30/2005 12:10:00 8.6 0.8 10.7 6.8 8.5 0.7 10.7 6.8 0.4 0 0.4 0.4 43 5 45 305 8 0 8 0 -14.4 0.1 -14.1 -14.6 01/30/2005 12:20:00 8.4 0.8 10.7 6.8 8.2 0.8 10.7 6.5 0.4 0 0.4 0.4 41 6 39 305 8 0 8 0 -14.4 0.1 -13.9 -14.6 01/30/2005 12:30:00 8.4 0.7 10.7 6.5 8.2 0.8 11.1 6.1 0.4 0 0.4 0.4 40 6 42 305 8 0 8 0 -14.3 0 -13.9 -14.6 01/30/2005 12:40:00 8.5 0.7 10.3 6.8 8.3 0.8 11.5 6.5 0.4 0 0.4 0.4 40 6 47 305 8 0 8 0 -14.2 0 -13.7 -14.4 01/30/2005 12:50:00 8.8 0.8 11.1 6.5 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 40 6 46 305 8 0 8 0 -14.2 0 -13.7 -14.3 01/30/2005 13:00:00 9.1 1.1 12.2 6.5 8.8 1.1 11.8 6.5 0.4 0 0.4 0.4 37 6 36 305 9 0 9 0 -13.9 0.1 -13.3 -14.1 01/30/2005 13:10:00 9.6 1 12.6 7.6 9.4 1 12.2 6.8 0.4 0 0.4 0.4 38 6 40 305 10 0 10 0 -13.8 0 -13.3 -14.1 01/30/2005 13:20:00 10.3 1 12.2 7.6 9.9 1 12.6 7.6 0.4 0 0.4 0.4 40 6 46 305 10 0 11 0 -13.6 0.1 -13.1 -13.7 01/30/2005 13:30:00 9.7 1 11.8 7.2 9.4 1 11.8 6.8 0.4 0 0.4 0.4 40 7 31 305 11 0 11 0 -13.5 0.1 -13.1 -13.7 01/30/2005 13:40:00 9.7 1 11.8 7.2 9.4 1 11.8 7.2 0.4 0 0.4 0.4 39 7 47 305 10 0 11 0 -13.5 0.1 -13.1 -13.7 01/30/2005 13:50:00 8.8 1.1 11.8 6.5 8.6 1.2 11.8 5.7 0.4 0 0.4 0.4 40 6 33 305 10 0 10 0 -13.5 0.1 -13.1 -13.7 01/30/2005 14:00:00 8.9 1 11.8 6.8 8.7 1 11.5 6.8 0.4 0 0.4 0.4 40 7 32 305 10 0 10 0 -13.4 0.1 -12.9 -13.5 01/30/2005 14:10:00 8.8 1 11.5 6.5 8.6 1 11.8 6.5 0.4 0 0.4 0.4 41 6 45 305 10 0 10 0 -13.4 0.1 -12.9 -13.7 01/30/2005 14:20:00 8.2 0.9 10.7 6.1 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 40 6 42 305 10 0 10 0 -13.4 0.1 -12.9 -13.5 01/30/2005 14:30:00 8.7 1.1 12.2 6.1 8.5 1.2 11.8 5.3 0.4 0 0.4 0.4 43 6 51 305 10 0 10 0 -13.5 0.1 -12.9 -13.7 01/30/2005 14:40:00 8.7 1.1 11.5 6.1 8.6 1.1 11.8 6.1 0.4 0 0.4 0.4 41 6 40 305 10 0 9 0 -13.5 0.1 -12.9 -13.7 01/30/2005 14:50:00 8.5 1 11.5 6.1 8.4 1 11.8 6.5 0.4 0 0.4 0.4 44 6 43 305 9 0 9 0 -13.5 0.1 -12.9 -13.7 01/30/2005 15:00:00 8.9 1.3 12.2 5.7 8.8 1.3 12.2 6.1 0.4 0 0.4 0.4 41 6 41 305 9 0 9 0 -13.4 0.1 -12.9 -13.7 01/30/2005 15:10:00 9.3 1 12.2 7.2 9.2 1 11.8 6.5 0.4 0 0.4 0.4 41 6 47 305 9 0 9 0 -13.5 0.1 -12.9 -13.7 01/30/2005 15:20:00 10 0.9 12.6 7.6 9.9 0.9 12.2 7.2 0.4 0 0.4 0.4 42 5 41 305 8 0 8 0 -13.5 0.1 -13.1 -13.7 01/30/2005 15:30:00 9.6 0.8 11.5 7.2 9.6 0.8 11.5 6.8 0.4 0 0.4 0.4 43 5 48 305 8 0 8 0 -13.6 0.1 -13.1 -13.7 01/30/2005 15:40:00 9.8 0.9 11.8 7.6 9.5 0.9 11.8 7.6 0.4 0 0.4 0.4 40 5 35 305 8 0 8 0 -13.6 0 -13.1 -13.7 01/30/2005 15:50:00 9.1 1 11.5 6.8 9 1 11.5 6.5 0.4 0 0.4 0.4 43 6 43 305 8 0 8 0 -13.6 0 -13.3 -13.7 01/30/2005 16:00:00 8.4 0.9 10.7 5.7 8.3 1 11.5 5.7 0.4 0 0.4 0.4 45 5 45 305 8 0 8 0 -13.7 0 -13.3 -13.9 01/30/2005 16:10:00 8.6 1.2 12.2 6.1 8.5 1.2 12.2 6.1 0.4 0 0.4 0.4 46 6 44 305 8 0 8 0 -13.8 0 -13.3 -13.9 01/30/2005 16:20:00 8.7 0.8 11.5 6.5 8.5 0.8 11.5 6.5 0.4 0 0.4 0.4 47 6 50 305 8 0 8 0 -13.8 0 -13.3 -13.9 01/30/2005 16:30:00 8.8 0.9 11.5 6.8 8.6 0.9 11.1 6.8 0.4 0 0.4 0.4 46 5 52 305 8 0 8 0 -13.8 0 -13.3 -14.1 01/30/2005 16:40:00 8.4 0.7 10.3 6.5 8.3 0.7 10.3 6.5 0.4 0 0.4 0.4 46 5 42 305 8 0 8 0 -13.9 0.1 -13.5 -14.3 01/30/2005 16:50:00 9 0.6 10.7 6.8 8.9 0.7 10.7 6.8 0.4 0 0.4 0.4 48 4 47 305 8 0 8 0 -14 0.1 -13.5 -14.3 01/30/2005 17:00:00 9.3 0.6 10.7 8 9.2 0.6 11.1 7.6 0.4 0 0.4 0.4 48 5 56 305 8 0 8 0 -14 0.1 -13.5 -14.3 01/30/2005 17:10:00 9.5 0.6 11.1 7.6 9.4 0.6 11.1 7.6 0.4 0 0.4 0.4 48 4 45 305 8 0 8 0 -14.1 0 -13.7 -14.3 01/30/2005 17:20:00 9.3 0.8 11.5 7.6 9.1 0.8 11.1 7.2 0.4 0 0.4 0.4 44 5 40 305 8 0 8 0 -14.1 0 -13.7 -14.3 01/30/2005 17:30:00 7.9 0.8 9.5 5.7 7.7 0.9 9.5 6.1 0.4 0 0.4 0.4 36 5 39 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 01/30/2005 17:40:00 7.6 0.7 9.1 5.7 7.3 0.7 9.1 5.3 0.4 0 0.4 0.4 39 5 33 305 7 0 8 0 -14.2 0 -13.7 -14.3 01/30/2005 17:50:00 7.3 0.7 9.1 5.7 7.1 0.6 8.8 5.7 0.4 0 0.4 0.4 34 5 28 305 7 0 7 0 -14.3 0 -13.9 -14.4 01/30/2005 18:00:00 7.5 0.5 8.8 6.1 7.2 0.5 9.1 5.7 0.4 0 0.4 0.4 33 5 35 305 7 0 7 0 -14.4 0.1 -13.9 -14.6 01/30/2005 18:10:00 7.9 0.8 9.9 6.5 7.8 0.8 9.5 6.1 0.4 0 0.4 0.4 36 5 34 305 7 0 7 0 -14.5 0 -14.1 -14.6 01/30/2005 18:20:00 8 0.6 9.9 6.5 7.9 0.7 9.5 6.5 0.4 0 0.4 0.4 38 5 29 305 7 0 7 0 -14.6 0.1 -14.3 -14.6 01/30/2005 18:30:00 8.3 0.6 9.9 6.5 8.1 0.7 9.5 6.1 0.4 0 0.4 0.4 37 5 37 305 7 0 7 0 -14.7 0 -14.4 -14.6 01/30/2005 18:40:00 8.7 0.6 10.3 7.2 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 37 4 36 305 7 0 7 0 -14.7 0 -14.4 -14.8 01/30/2005 18:50:00 8.8 0.6 10.3 7.2 8.6 0.6 10.3 6.8 0.4 0 0.4 0.4 37 4 39 305 7 0 7 0 -14.7 0 -14.3 -14.8 01/30/2005 19:00:00 9 0.7 11.1 7.2 8.7 0.7 11.1 6.8 0.4 0 0.4 0.4 36 5 38 305 7 0 7 0 -14.7 0 -14.3 -14.8 01/30/2005 19:10:00 8.6 0.7 10.3 6.5 8.2 0.8 10.3 6.1 0.4 0 0.4 0.4 33 5 32 305 7 0 7 0 -14.7 0 -14.3 -14.8 01/30/2005 19:20:00 8 0.7 9.9 6.5 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 35 5 38 305 7 0 7 0 -14.7 0 -14.3 -15 01/30/2005 19:30:00 7.7 0.6 9.1 5.7 7.5 0.7 9.1 5.3 0.4 0 0.4 0.4 35 6 36 305 7 0 7 0 -14.8 0 -14.4 -15 01/30/2005 19:40:00 8.4 0.7 10.7 6.5 8.2 0.7 9.9 6.1 0.4 0 0.4 0.4 37 5 37 305 7 0 7 0 -14.7 0 -14.4 -15 01/30/2005 19:50:00 7.9 0.7 9.9 6.1 7.6 0.8 9.9 5.7 0.4 0 0.4 0.4 33 5 32 305 7 0 7 0 -14.8 0 -14.4 -15 01/30/2005 20:00:00 7.6 0.6 9.5 6.1 7.3 0.7 8.8 5.7 0.4 0 0.4 0.4 34 6 34 305 7 0 7 0 -14.8 0 -14.4 -15 01/30/2005 20:10:00 7.5 0.8 9.5 5.3 7.4 0.8 9.1 4.9 0.4 0 0.4 0.4 35 5 36 305 7 0 7 0 -14.9 0 -14.4 -15 01/30/2005 20:20:00 7.8 0.8 9.9 6.1 7.6 0.8 9.5 5.7 0.4 0 0.4 0.4 34 6 37 305 7 0 7 0 -14.7 0 -14.4 -15 01/30/2005 20:30:00 7.7 0.7 9.9 6.1 7.5 0.8 9.1 5.7 0.4 0 0.4 0.4 33 6 26 305 7 0 7 0 -14.7 0 -14.4 -15 01/30/2005 20:40:00 7.8 0.8 9.9 6.1 7.5 0.7 9.5 6.1 0.4 0 0.4 0.4 35 6 33 305 7 0 7 0 -14.7 0.1 -14.4 -15 01/30/2005 20:50:00 7.7 0.8 9.9 5.7 7.4 0.8 9.5 5.7 0.4 0 0.4 0.4 38 5 39 305 7 0 7 0 -14.8 0 -14.6 -15 01/30/2005 21:00:00 7.3 0.8 9.1 4.9 7.1 0.8 9.1 4.9 0.4 0 0.4 0.4 41 6 35 305 7 0 7 0 -14.8 0.1 -14.4 -15 01/30/2005 21:10:00 6.7 0.7 8.8 4.9 6.5 0.7 8.4 4.9 0.4 0 0.4 0.4 42 6 41 305 7 0 7 0 -14.9 0 -14.6 -15 01/30/2005 21:20:00 6.4 0.7 8.8 4.6 6.2 0.7 8 4.6 0.4 0 0.4 0.4 40 5 39 305 7 0 7 0 -15 0 -14.6 -15 01/30/2005 21:30:00 6.5 0.6 8.4 4.9 6.3 0.7 8.4 4.9 0.4 0 0.4 0.4 40 5 45 305 7 0 7 0 -15 0.1 -14.6 -15.2 01/30/2005 21:40:00 6 0.6 7.2 4.2 5.8 0.6 7.2 3.8 0.4 0 0.4 0.4 34 5 35 305 7 0 7 0 -15.1 0 -14.6 -15.2 01/30/2005 21:50:00 5.2 0.7 7.6 3.8 4.9 0.7 6.8 3.8 0.4 0 0.4 0.4 34 6 32 305 7 0 7 0 -15.1 0.1 -14.6 -15.2 01/30/2005 22:00:00 4.6 0.5 6.1 3.4 4.4 0.5 5.7 3.4 0.4 0 0.4 0.4 41 6 27 305 7 0 7 0 -15.2 0 -14.8 -15.4 01/30/2005 22:10:00 4.7 0.7 6.5 3.4 4.3 0.7 6.8 2.6 0.4 0 0.4 0.4 41 6 48 305 7 0 7 0 -15.3 0 -15 -15.6 01/30/2005 22:20:00 4.8 0.5 6.8 3.4 4.6 0.5 6.1 3 0.4 0 0.4 0.4 37 6 23 305 7 0 7 0 -15.3 0 -14.8 -15.4 01/30/2005 22:30:00 5.3 0.5 6.8 4.2 5.1 0.5 6.8 4.2 0.4 0 0.4 0.4 34 5 29 305 7 0 7 0 -15.3 0 -15 -15.4 01/30/2005 22:40:00 5.5 0.6 7.2 4.2 5.3 0.6 6.8 4.2 0.4 0 0.4 0.4 36 6 37 305 7 0 7 0 -15.3 0 -15 -15.6 01/30/2005 22:50:00 5.3 0.5 6.8 4.2 5.1 0.6 6.8 3.8 0.4 0 0.4 0.4 39 5 49 305 7 0 7 0 -15.4 0 -15 -15.6 01/30/2005 23:00:00 6.2 0.6 8 4.6 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 36 5 37 305 7 0 7 0 -15.3 0 -14.8 -15.6 01/30/2005 23:10:00 5.9 0.5 7.2 4.9 5.7 0.5 7.2 4.6 0.4 0 0.4 0.4 39 5 41 305 7 0 7 0 -15.5 0.1 -15 -15.6 01/30/2005 23:20:00 6 0.5 7.6 4.6 5.8 0.5 7.2 4.6 0.4 0 0.4 0.4 42 5 42 305 7 0 7 0 -15.6 0.1 -15.2 -15.8 01/30/2005 23:30:00 6 0.6 8 4.6 5.8 0.7 7.6 3.8 0.4 0 0.4 0.4 42 5 44 305 7 0 7 0 -15.6 0.1 -15.2 -15.8 01/30/2005 23:40:00 6.5 0.6 8.4 4.9 6.4 0.6 8.4 4.9 0.4 0 0.4 0.4 44 5 42 305 7 0 7 0 -15.5 0.1 -15 -15.8 01/30/2005 23:50:00 6.4 0.5 8 4.9 6.2 0.5 7.6 4.9 0.4 0 0.4 0.4 42 5 26 305 7 0 7 0 -15.7 0.1 -15.2 -15.8 01/31/2005 00:00:00 6.8 0.6 8.4 5.3 6.6 0.6 8.4 4.9 0.4 0 0.4 0.4 41 5 33 305 7 0 7 0 -15.6 0.1 -15.2 -15.8 01/31/2005 00:10:00 7 0.7 8.8 5.3 6.7 0.6 8.4 4.9 0.4 0 0.4 0.4 41 5 40 305 7 0 7 0 -15.5 0 -15.2 -15.6 01/31/2005 00:20:00 6.7 0.9 9.1 4.6 6.3 0.9 8.8 4.2 0.4 0 0.4 0.4 39 6 41 305 7 0 7 0 -15.5 0 -15 -15.6 01/31/2005 00:30:00 5.5 0.7 8.4 4.2 5.1 0.7 7.6 3.4 0.4 0 0.4 0.4 38 6 30 305 7 0 7 0 -15.6 0.1 -15.2 -15.8 01/31/2005 00:40:00 5.2 0.7 7.6 3.4 4.9 0.8 6.8 3 0.4 0 0.4 0.4 39 7 24 305 7 0 7 0 -15.7 0.1 -15.2 -15.8 01/31/2005 00:50:00 5.1 0.7 8 3.4 4.7 0.8 6.8 3 0.4 0 0.4 0.4 44 7 31 305 7 0 7 0 -15.8 0 -15.4 -16 01/31/2005 01:00:00 4.8 0.6 6.1 3.4 4.5 0.7 6.1 2.6 0.4 0 0.4 0.4 43 6 33 305 7 0 7 0 -15.8 0 -15.4 -15.8 01/31/2005 01:10:00 5.3 0.5 6.8 4.2 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 43 6 45 305 7 0 7 0 -15.7 0.1 -15.2 -15.8 01/31/2005 01:20:00 5.7 0.5 7.2 4.2 5.5 0.6 6.8 4.2 0.4 0 0.4 0.4 45 5 42 305 7 0 7 0 -15.8 0 -15.4 -15.8 01/31/2005 01:30:00 5.8 0.6 7.2 4.2 5.4 0.6 7.6 3.4 0.4 0 0.4 0.4 45 6 45 305 7 0 6 0 -15.8 0 -15.6 -15.8 01/31/2005 01:40:00 6 0.6 7.6 4.6 5.6 0.6 7.2 3.8 0.4 0 0.4 0.4 46 7 53 305 7 0 7 0 -15.8 0 -15.6 -16 01/31/2005 01:50:00 5.2 0.5 7.2 3.8 4.9 0.7 7.2 3.4 0.4 0 0.4 0.4 42 6 40 305 6 0 7 0 -15.8 0 -15.4 -16 01/31/2005 02:00:00 5.1 0.4 6.1 4.2 4.8 0.5 6.1 3.4 0.4 0 0.4 0.4 41 4 36 305 6 0 6 0 -15.9 0 -15.8 -16.2 01/31/2005 02:10:00 5.6 0.4 6.8 4.6 5.3 0.4 6.8 4.2 0.4 0 0.4 0.4 42 4 39 305 6 0 6 0 -16 0.1 -15.8 -16.2 01/31/2005 02:20:00 6 0.5 7.6 4.9 5.6 0.5 7.2 4.2 0.4 0 0.4 0.4 39 5 35 305 6 0 6 0 -16 0 -15.8 -16.2 01/31/2005 02:30:00 7 0.6 9.1 5.7 6.6 0.6 8 5.3 0.4 0 0.4 0.4 37 4 47 305 6 0 6 0 -16 0 -15.8 -16.2 01/31/2005 02:40:00 7.1 0.7 8.8 5.3 6.7 0.8 8.4 4.9 0.4 0 0.4 0.4 40 4 44 305 6 0 6 0 -16 0 -15.8 -16.2 01/31/2005 02:50:00 5.8 0.7 7.6 4.2 5.4 0.7 7.6 3.8 0.4 0 0.4 0.4 44 6 48 305 6 0 6 0 -16.1 0.1 -15.8 -16.4 01/31/2005 03:00:00 5.5 0.5 6.8 3.8 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 42 6 44 305 6 0 6 0 -16.1 0 -15.8 -16.4 01/31/2005 03:10:00 5.6 0.6 8 4.2 5.2 0.6 7.6 3.8 0.4 0 0.4 0.4 38 5 30 305 6 0 6 0 -16.2 0.1 -15.8 -16.4 01/31/2005 03:20:00 4.6 0.6 6.1 2.6 4.1 0.7 6.1 1.9 0.4 0 0.4 0.4 40 7 40 305 6 0 6 0 -16.2 0.1 -16 -16.4 01/31/2005 03:30:00 5 0.8 6.5 3 4.7 0.8 6.5 3 0.4 0 0.4 0.4 42 6 39 305 6 0 6 0 -16.2 0 -15.8 -16.4 01/31/2005 03:40:00 4.8 0.6 6.5 3 4.4 0.6 5.7 2.6 0.4 0 0.4 0.4 37 6 48 305 6 0 6 0 -16.2 0 -15.8 -16.4 01/31/2005 03:50:00 5 0.6 6.8 2.6 4.6 0.6 5.7 2.3 0.4 0 0.4 0.4 35 6 21 305 6 0 6 0 -16.1 0 -15.8 -16.2 01/31/2005 04:00:00 5.1 0.4 6.5 4.2 4.9 0.4 6.1 3.8 0.4 0 0.4 0.4 32 4 35 305 6 0 6 0 -16.1 0 -15.8 -16.4 01/31/2005 04:10:00 4.9 0.6 6.5 3.8 4.7 0.6 6.1 3.4 0.4 0 0.4 0.4 33 4 34 305 6 0 6 0 -16.1 0.1 -15.8 -16.4 01/31/2005 04:20:00 5 0.4 6.5 3.8 4.8 0.5 6.1 3.8 0.4 0 0.4 0.4 36 4 33 305 6 0 6 0 -16.2 0.1 -15.8 -16.4 01/31/2005 04:30:00 5.1 0.5 6.5 4.2 4.9 0.4 6.1 3.8 0.4 0 0.4 0.4 37 4 42 305 6 0 6 0 -16.3 0 -16 -16.4 01/31/2005 04:40:00 4.6 0.5 5.7 3.4 4.4 0.5 5.7 3 0.4 0 0.4 0.4 41 5 31 305 6 0 6 0 -16.4 0 -16 -16.6 01/31/2005 04:50:00 5.8 0.5 7.2 4.6 5.7 0.4 6.8 4.6 0.4 0 0.4 0.4 45 5 50 305 6 0 6 0 -16.3 0 -16 -16.6 01/31/2005 05:00:00 6.3 0.5 8 5.3 6.1 0.6 8 4.6 0.4 0 0.4 0.4 46 4 48 305 6 0 6 0 -16.3 0 -16 -16.6 01/31/2005 05:10:00 6.9 0.5 8 5.7 6.8 0.5 8.4 5.7 0.4 0 0.4 0.4 44 4 40 305 6 0 6 0 -16.4 0 -16 -16.6 01/31/2005 05:20:00 6.8 0.3 7.6 6.1 6.7 0.3 7.6 5.7 0.4 0 0.4 0.4 41 4 42 305 6 0 6 0 -16.5 0 -16 -16.7 01/31/2005 05:30:00 7 0.5 8.4 6.1 6.8 0.5 8.4 5.7 0.4 0 0.4 0.4 39 3 44 305 6 0 6 0 -16.5 0 -16.2 -16.7 01/31/2005 05:40:00 7.2 0.6 8.8 5.7 6.9 0.7 8.4 5.3 0.4 0 0.4 0.4 37 4 38 305 6 0 6 0 -16.4 0 -16 -16.6 01/31/2005 05:50:00 6.8 0.6 8.4 5.3 6.5 0.6 8 4.6 0.4 0 0.4 0.4 38 4 38 305 6 0 6 0 -16.4 0 -16 -16.6 01/31/2005 06:00:00 7 0.6 8.8 5.7 6.7 0.7 9.1 4.9 0.4 0 0.4 0.4 40 5 42 305 6 0 6 0 -16.4 0 -16 -16.6 01/31/2005 06:10:00 6.8 0.7 9.1 5.3 6.5 0.7 9.1 4.6 0.4 0 0.4 0.4 40 5 42 305 6 0 6 0 -16.4 0 -16 -16.6 01/31/2005 06:20:00 7.2 0.6 8.8 5.3 6.9 0.6 8.8 4.9 0.4 0 0.4 0.4 41 6 41 305 6 0 6 0 -16.4 0 -16 -16.6 01/31/2005 06:30:00 7.8 0.7 9.9 5.7 7.6 0.7 9.9 5.7 0.4 0 0.4 0.4 40 5 36 305 6 0 6 0 -16.4 0 -16 -16.6 01/31/2005 06:40:00 8.2 0.5 9.5 6.8 8 0.6 9.9 6.5 0.4 0 0.4 0.4 41 4 44 305 6 0 6 0 -16.3 0 -16 -16.6 01/31/2005 06:50:00 8.7 0.6 9.9 7.2 8.6 0.6 10.3 6.8 0.4 0 0.4 0.4 42 4 36 305 6 0 6 0 -16.4 0 -16 -16.6 01/31/2005 07:00:00 9.3 0.5 10.7 8 9 0.6 10.7 7.6 0.4 0 0.4 0.4 44 4 38 305 6 0 6 0 -16.3 0 -15.8 -16.6 01/31/2005 07:10:00 9.7 0.6 11.1 8.4 9.5 0.6 11.8 8 0.4 0 0.4 0.4 45 4 39 305 6 0 6 0 -16.3 0.1 -15.8 -16.6 01/31/2005 07:20:00 10.3 0.6 12.2 8.4 10.1 0.7 12.6 8 0.4 0 0.4 0.4 46 4 43 305 6 0 6 0 -16.2 0 -15.8 -16.4 01/31/2005 07:30:00 10.4 0.6 11.8 8.8 10.3 0.7 11.8 8 0.4 0 0.4 0.4 47 4 42 305 6 0 6 0 -16.1 0.1 -15.8 -16.4 01/31/2005 07:40:00 10.4 0.7 12.2 8 10.3 0.8 12.6 8.4 0.4 0 0.4 0.4 48 4 55 305 6 0 6 0 -16.1 0 -15.6 -16.2 01/31/2005 07:50:00 10.8 0.7 13 9.1 10.7 0.8 13 8.4 0.4 0 0.4 0.4 49 4 45 305 6 0 6 0 -16 0 -15.6 -16.4 01/31/2005 08:00:00 10.5 0.6 12.6 8.8 10.5 0.6 12.2 8.8 0.4 0 0.4 0.4 49 4 42 305 6 0 6 0 -16.1 0 -15.6 -16.2 01/31/2005 08:10:00 10 0.6 11.8 8.4 9.8 0.7 11.5 8 0.4 0 0.4 0.4 46 5 38 305 6 0 6 0 -16.3 0.1 -15.8 -16.4 01/31/2005 08:20:00 10.3 0.7 12.2 8 10.1 0.7 11.8 8 0.4 0 0.4 0.4 45 4 39 305 6 0 6 0 -16.3 0 -16 -16.6 01/31/2005 08:30:00 10.7 0.7 12.2 9.1 10.5 0.7 12.6 8.8 0.4 0 0.4 0.4 46 4 46 305 6 0 6 0 -16.3 0 -16 -16.6 01/31/2005 08:40:00 10.2 0.7 11.8 8 10.1 0.8 11.8 7.6 0.4 0 0.4 0.4 45 4 56 305 6 0 6 0 -16.4 0 -16 -16.6 01/31/2005 08:50:00 9.9 0.7 11.5 8 9.8 0.8 11.5 7.6 0.4 0 0.4 0.4 43 4 38 305 6 0 6 0 -16.5 0 -16.2 -16.6 01/31/2005 09:00:00 9.8 0.7 11.8 8 9.6 0.8 11.8 7.2 0.4 0 0.4 0.4 44 4 47 305 6 0 6 0 -16.6 0.1 -16.2 -16.9 01/31/2005 09:10:00 10 0.7 11.8 8 9.8 0.8 11.5 8 0.4 0 0.4 0.4 45 5 36 305 6 0 6 0 -16.7 0 -16.4 -16.9 01/31/2005 09:20:00 9.6 0.8 12.2 7.2 9.4 0.8 11.8 7.6 0.4 0 0.4 0.4 45 4 37 305 6 0 6 0 -16.7 0.1 -16.4 -16.9 01/31/2005 09:30:00 9.9 0.6 11.5 7.6 9.7 0.6 11.5 8 0.4 0 0.4 0.4 46 4 41 305 6 0 6 0 -16.8 0.1 -16.4 -16.9 01/31/2005 09:40:00 9.8 0.5 11.5 8.8 9.6 0.6 11.5 8 0.4 0 0.4 0.4 46 4 46 305 6 0 6 0 -16.9 0 -16.6 -16.9 01/31/2005 09:50:00 9.8 0.6 11.5 8.4 9.6 0.7 11.5 8 0.4 0 0.4 0.4 46 4 47 305 6 0 6 0 -16.9 0 -16.6 -16.9 01/31/2005 10:00:00 9.8 0.6 11.5 8 9.6 0.7 11.5 7.6 0.4 0 0.4 0.4 45 5 54 305 6 0 6 0 -16.9 0 -16.6 -17.1 01/31/2005 10:10:00 9.4 0.6 10.7 7.6 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 45 4 45 305 6 0 6 0 -17 0 -16.9 -17.1 01/31/2005 10:20:00 9.6 0.6 11.5 8 9.4 0.8 11.5 7.6 0.4 0 0.4 0.4 44 4 38 305 6 0 6 0 -17 0 -16.7 -17.3 01/31/2005 10:30:00 9.4 0.6 11.5 7.6 9.4 0.7 11.8 7.6 0.4 0 0.4 0.4 41 4 36 305 6 0 6 0 -17 0 -16.9 -17.1 01/31/2005 10:40:00 9.7 0.6 11.1 8 9.6 0.7 11.8 8 0.4 0 0.4 0.4 43 4 43 305 6 0 6 0 -16.9 0 -16.6 -17.1 01/31/2005 10:50:00 9.2 0.5 11.1 8 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 45 4 48 305 6 0 6 0 -17 0 -16.9 -17.1 01/31/2005 11:00:00 9.2 0.6 10.7 7.6 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 44 4 43 305 6 0 6 0 -17 0 -16.9 -17.1 01/31/2005 11:10:00 9 0.5 10.7 6.8 8.9 0.6 10.3 6.8 0.4 0 0.4 0.4 43 4 39 305 6 0 6 0 -17 0 -16.9 -17.3 01/31/2005 11:20:00 8.6 0.7 10.3 6.8 8.4 0.7 10.3 6.8 0.4 0 0.4 0.4 42 4 34 305 6 0 6 0 -17.1 0 -16.9 -17.3 01/31/2005 11:30:00 8.4 0.4 9.9 7.2 8.3 0.5 9.5 6.8 0.4 0 0.4 0.4 44 4 37 305 6 0 6 0 -17.2 0 -16.9 -17.3 01/31/2005 11:40:00 7.8 0.4 9.1 6.8 7.7 0.4 8.8 6.5 0.4 0 0.4 0.4 42 4 43 305 6 0 6 0 -17.3 0.1 -16.9 -17.5 01/31/2005 11:50:00 7.6 0.5 9.1 6.5 7.5 0.5 9.1 6.1 0.4 0 0.4 0.4 38 3 38 305 5 0 5 0 -17.3 0 -16.9 -17.5 01/31/2005 12:00:00 7.7 0.4 9.1 6.5 7.6 0.5 8.8 6.5 0.4 0 0.4 0.4 36 3 36 305 5 0 5 0 -17.4 0 -16.9 -17.5 01/31/2005 12:10:00 7.3 0.5 8.8 6.1 7.2 0.5 8.8 5.7 0.4 0 0.4 0.4 36 3 35 305 6 0 6 0 -17.4 0 -17.1 -17.5 01/31/2005 12:20:00 7.6 0.5 9.5 6.1 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 38 4 31 305 6 0 6 0 -17.3 0.1 -16.9 -17.5 01/31/2005 12:30:00 6.8 0.4 7.6 6.1 6.7 0.5 8 5.7 0.4 0 0.4 0.4 39 4 39 305 6 0 6 0 -17.4 0 -17.1 -17.5 01/31/2005 12:40:00 6.8 0.4 7.6 5.7 6.6 0.4 7.6 5.3 0.4 0 0.4 0.4 36 3 40 305 5 0 5 0 -17.5 0 -17.1 -17.7 01/31/2005 12:50:00 6.7 0.5 7.6 5.3 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 36 3 36 305 6 0 6 0 -17.3 0.1 -16.9 -17.5 01/31/2005 13:00:00 7.5 0.6 9.1 6.1 7.3 0.7 9.1 5.3 0.4 0 0.4 0.4 36 4 38 305 6 0 7 0 -16.9 0 -16.6 -17.1 01/31/2005 13:10:00 6.8 0.5 8 5.3 6.6 0.5 8 4.9 0.4 0 0.4 0.4 31 4 27 305 6 0 7 0 -16.7 0.1 -16.2 -16.9 01/31/2005 13:20:00 6.8 0.6 8 5.3 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 31 4 31 305 7 0 7 0 -16.5 0.1 -16 -16.6 01/31/2005 13:30:00 6.6 0.6 8 5.3 6.4 0.6 8 4.9 0.4 0 0.4 0.4 32 3 30 305 7 0 7 0 -16.3 0.1 -15.8 -16.6 01/31/2005 13:40:00 6.5 0.7 8.8 4.9 6.3 0.7 8.8 4.9 0.4 0 0.4 0.4 36 4 36 305 8 0 8 0 -16.1 0 -15.8 -16.4 01/31/2005 13:50:00 6.8 0.5 8.4 5.3 6.7 0.5 8 5.3 0.4 0 0.4 0.4 35 5 30 305 7 0 8 0 -15.9 0 -15.4 -16 01/31/2005 14:00:00 7.1 0.6 8.8 5.3 7 0.6 8.8 5.3 0.4 0 0.4 0.4 32 4 34 305 7 0 7 0 -15.8 0.1 -15.2 -16 01/31/2005 14:10:00 8.2 0.5 9.9 6.8 8 0.6 9.5 6.5 0.4 0 0.4 0.4 34 4 34 305 7 0 7 0 -15.7 0.1 -15.2 -15.8 01/31/2005 14:20:00 8.7 0.6 10.3 7.2 8.6 0.6 9.9 6.8 0.4 0 0.4 0.4 29 4 34 305 7 0 7 0 -15.5 0 -15 -15.6 01/31/2005 14:30:00 8.9 0.5 10.3 7.2 9 0.6 10.3 6.8 0.4 0 0.4 0.4 21 4 26 305 7 0 7 0 -15.8 0.2 -15 -16.2 01/31/2005 14:40:00 8.9 0.6 10.3 6.5 8.8 0.7 10.3 6.5 0.4 0 0.4 0.4 24 3 27 305 6 0 7 0 -16.1 0 -15.6 -16.4 01/31/2005 14:50:00 8.2 0.6 9.9 6.5 8.1 0.7 9.9 6.5 0.4 0 0.4 0.4 23 5 25 305 6 0 6 0 -16.3 0.1 -15.8 -16.6 01/31/2005 15:00:00 8.6 0.4 9.9 7.6 8.6 0.5 9.9 7.2 0.4 0 0.4 0.4 23 4 19 305 6 0 6 0 -16.6 0.1 -16 -16.9 01/31/2005 15:10:00 8.3 0.6 9.9 6.5 8.3 0.7 9.9 6.1 0.4 0 0.4 0.4 21 4 18 305 6 0 6 0 -16.8 0.1 -16.4 -16.9 01/31/2005 15:20:00 8.7 0.6 9.9 7.2 8.7 0.6 9.9 6.8 0.4 0 0.4 0.4 22 4 17 305 6 0 6 0 -16.9 0 -16.6 -16.9 01/31/2005 15:30:00 9 0.6 10.3 7.2 8.9 0.6 10.7 7.2 0.4 0 0.4 0.4 28 3 32 305 6 0 6 0 -16.9 0 -16.4 -16.9 01/31/2005 15:40:00 9.2 0.6 10.7 7.6 9.1 0.6 10.7 7.6 0.4 0 0.4 0.4 29 4 31 305 6 0 6 0 -16.7 0.1 -16.4 -16.9 01/31/2005 15:50:00 9.1 0.8 11.1 7.2 8.9 0.9 11.5 7.2 0.4 0 0.4 0.4 29 5 26 305 6 0 6 0 -16.7 0.1 -16.4 -16.9 01/31/2005 16:00:00 9.6 0.7 11.5 7.6 9.4 0.7 11.1 7.6 0.4 0 0.4 0.4 32 5 28 305 6 0 6 0 -16.6 0 -16.2 -16.9 01/31/2005 16:10:00 9.7 0.8 11.5 7.6 9.7 0.9 12.2 7.6 0.4 0 0.4 0.4 36 6 56 305 6 0 6 0 -16.6 0 -16.2 -16.9 01/31/2005 16:20:00 10.6 0.8 13 8.4 10.5 0.9 13 8.4 0.4 0 0.4 0.4 36 6 40 305 6 0 6 0 -16.8 0.1 -16.4 -16.9 01/31/2005 16:30:00 11.4 0.7 13 9.1 11.3 0.7 13 8.8 0.4 0 0.4 0.4 37 5 33 305 6 0 6 0 -16.9 0 -16.6 -16.9 01/31/2005 16:40:00 10.2 1 11.8 7.6 10.1 1 12.2 7.6 0.4 0 0.4 0.4 39 5 42 305 6 0 6 0 -16.9 0 -16.6 -17.1 01/31/2005 16:50:00 10.7 0.7 12.6 8.4 10.6 0.8 12.2 8.4 0.4 0 0.4 0.4 36 4 37 305 6 0 6 0 -16.9 0 -16.7 -16.9 01/31/2005 17:00:00 10.1 0.8 12.2 8 10 0.9 12.2 7.6 0.4 0 0.4 0.4 33 5 32 305 6 0 6 0 -16.9 0 -16.4 -16.9 01/31/2005 17:10:00 10.3 0.6 11.8 8.4 10.1 0.7 11.8 8 0.4 0 0.4 0.4 34 5 41 305 6 0 6 0 -16.9 0 -16.4 -16.9 01/31/2005 17:20:00 8.9 1 11.5 6.5 8.8 1.1 11.5 6.1 0.4 0 0.4 0.4 37 7 37 305 6 0 6 0 -16.8 0.1 -16.4 -16.9 01/31/2005 17:30:00 8.9 0.7 10.7 6.5 8.8 0.8 10.7 6.8 0.4 0 0.4 0.4 31 6 25 305 6 0 6 0 -16.8 0.1 -16.4 -16.9 01/31/2005 17:40:00 8.9 0.9 10.7 6.5 8.8 0.9 10.7 6.5 0.4 0 0.4 0.4 26 6 24 305 6 0 6 0 -16.8 0 -16.4 -16.9 01/31/2005 17:50:00 8.8 0.6 10.3 7.2 8.8 0.7 10.3 6.8 0.4 0 0.4 0.4 32 7 27 305 6 0 6 0 -16.9 0 -16.6 -16.9 01/31/2005 18:00:00 8.8 0.7 11.1 6.8 8.8 0.7 11.1 6.8 0.4 0 0.4 0.4 30 6 27 305 6 0 6 0 -16.9 0 -16.6 -17.1 01/31/2005 18:10:00 8.3 0.7 9.9 6.5 8.3 0.7 9.9 6.1 0.4 0 0.4 0.4 29 5 30 305 6 0 6 0 -17.1 0 -16.9 -17.3 01/31/2005 18:20:00 8.3 0.8 10.7 6.5 8.2 0.8 10.7 6.5 0.4 0 0.4 0.4 28 6 21 305 6 0 6 0 -17.3 0.1 -16.9 -17.5 01/31/2005 18:30:00 8.3 0.8 10.3 6.1 8.2 0.9 10.7 6.1 0.4 0 0.4 0.4 28 6 32 305 6 0 6 0 -17.5 0 -16.9 -17.7 01/31/2005 18:40:00 8.1 0.7 9.9 6.5 8.1 0.7 10.3 6.1 0.4 0 0.4 0.4 29 5 31 305 6 0 6 0 -17.6 0 -17.3 -17.7 01/31/2005 18:50:00 7.8 0.5 8.8 6.1 7.7 0.6 9.5 6.1 0.4 0 0.4 0.4 33 6 26 305 5 0 5 0 -17.8 0.1 -17.5 -18.1 01/31/2005 19:00:00 7.5 0.7 9.1 5.3 7.5 0.8 9.1 5.3 0.4 0 0.4 0.4 27 5 30 305 5 0 5 0 -17.9 0 -17.5 -18.1 01/31/2005 19:10:00 7.7 0.8 9.1 5.7 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 28 5 29 305 5 0 5 0 -18 0 -17.7 -18.2 01/31/2005 19:20:00 7.5 0.9 9.1 5.3 7.4 0.9 9.5 5.3 0.4 0 0.4 0.4 31 5 30 305 5 0 5 0 -18.1 0 -17.9 -18.2 01/31/2005 19:30:00 8 0.8 9.5 6.1 7.9 0.9 9.9 6.1 0.4 0 0.4 0.4 35 5 36 305 5 0 5 0 -18.1 0 -18.1 -18.2 01/31/2005 19:40:00 7.6 0.7 9.1 5.7 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 36 5 36 305 5 0 5 0 -18 0 -17.9 -18.2 01/31/2005 19:50:00 8.1 0.7 9.9 6.5 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 34 6 40 305 5 0 5 0 -18 0 -17.7 -18.1 01/31/2005 20:00:00 8.1 0.8 9.9 5.7 8 0.8 9.5 5.7 0.4 0 0.4 0.4 36 5 41 305 5 0 5 0 -18 0 -17.7 -18.1 01/31/2005 20:10:00 7.7 0.7 9.1 5.3 7.7 0.8 9.1 5.7 0.4 0 0.4 0.4 37 5 33 305 5 0 5 0 -17.8 0 -17.5 -18.1 01/31/2005 20:20:00 8.2 0.6 9.1 5.7 8.2 0.6 9.5 6.1 0.4 0 0.4 0.4 41 6 44 305 5 0 5 0 -17.8 0 -17.5 -17.9 01/31/2005 20:30:00 7.5 0.9 9.1 5.3 7.5 0.9 9.5 5.3 0.4 0 0.4 0.4 37 6 40 305 5 0 5 0 -17.8 0 -17.5 -17.9 01/31/2005 20:40:00 7.8 0.6 9.1 6.1 7.8 0.6 9.1 5.7 0.4 0 0.4 0.4 36 6 38 305 5 0 5 0 -17.8 0.1 -17.5 -18.1 01/31/2005 20:50:00 7.6 0.7 9.1 6.1 7.6 0.7 9.1 5.7 0.4 0 0.4 0.4 44 4 41 305 5 0 5 0 -17.8 0.1 -17.5 -18.1 01/31/2005 21:00:00 7.7 0.6 9.1 5.7 7.7 0.7 9.5 5.7 0.4 0 0.4 0.4 36 5 32 305 5 0 5 0 -17.8 0 -17.5 -18.1 01/31/2005 21:10:00 7.6 0.7 8.8 5.3 7.5 0.8 9.5 5.3 0.4 0 0.4 0.4 39 5 40 305 5 0 5 0 -17.7 0 -17.5 -17.9 01/31/2005 21:20:00 7.2 0.5 8.8 6.1 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 32 5 43 305 5 0 5 0 -17.7 0 -17.5 -17.9 01/31/2005 21:30:00 7 0.6 8.4 5.3 7 0.7 8.8 5.3 0.4 0 0.4 0.4 29 5 27 305 5 0 5 0 -17.7 0 -17.5 -17.9 01/31/2005 21:40:00 7.2 0.6 8.8 5.7 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 30 6 37 305 5 0 5 0 -17.7 0 -17.5 -17.9 01/31/2005 21:50:00 7.4 0.6 8.8 5.7 7.4 0.6 8.4 5.7 0.4 0 0.4 0.4 27 5 34 305 5 0 5 0 -17.8 0 -17.5 -18.1 01/31/2005 22:00:00 7.5 0.7 8.8 5.3 7.6 0.7 9.1 5.3 0.4 0 0.4 0.4 33 6 34 305 5 0 5 0 -17.9 0.1 -17.5 -18.1 01/31/2005 22:10:00 7 0.6 8.4 4.9 7 0.6 8.4 4.9 0.4 0 0.4 0.4 30 7 17 305 5 0 5 0 -17.9 0 -17.5 -18.1 01/31/2005 22:20:00 6.8 0.5 8 5.3 6.7 0.6 8 4.9 0.4 0 0.4 0.4 35 4 33 305 5 0 5 0 -17.9 0 -17.7 -18.1 01/31/2005 22:30:00 7 0.5 8.8 5.3 7 0.6 8.4 5.7 0.4 0 0.4 0.4 34 5 34 305 5 0 5 0 -17.9 0 -17.5 -18.1 01/31/2005 22:40:00 7.3 0.6 8.8 5.7 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 31 6 31 305 5 0 5 0 -17.9 0 -17.5 -18.1 01/31/2005 22:50:00 7.3 0.7 8.8 5.7 7.2 0.7 8.8 5.3 0.4 0 0.4 0.4 29 8 30 305 5 0 5 0 -17.9 0 -17.5 -18.1 01/31/2005 23:00:00 7.9 0.7 9.5 6.1 8 0.7 9.5 5.7 0.4 0 0.4 0.4 27 5 26 305 5 0 5 0 -18.1 0 -17.7 -18.2 01/31/2005 23:10:00 7.1 0.8 9.1 5.7 6.9 0.8 9.5 4.6 0.4 0 0.4 0.4 25 7 23 305 5 0 5 0 -18.1 0 -18.1 -18.2 01/31/2005 23:20:00 7.9 0.8 9.5 5.7 7.9 0.8 9.5 5.7 0.4 0 0.4 0.4 33 5 35 305 5 0 5 0 -18.4 0.1 -18.1 -18.4 01/31/2005 23:30:00 7.8 1 9.5 5.3 7.8 1 9.9 4.9 0.4 0 0.4 0.4 33 6 30 305 5 0 5 0 -18.5 0 -18.2 -18.6 01/31/2005 23:40:00 8.2 1 9.9 5.7 8.1 1 9.5 5.3 0.4 0 0.4 0.4 31 5 30 305 5 0 5 0 -18.6 0 -18.4 -18.8 01/31/2005 23:50:00 8.1 0.9 10.3 5.7 8 0.9 10.3 5.7 0.4 0 0.4 0.4 34 7 41 305 5 0 5 0 -18.7 0 -18.4 -18.8 02/01/2005 00:00:00 8.4 0.8 9.9 6.1 8.3 0.8 9.9 6.1 0.4 0 0.4 0.4 35 9 50 305 4 0 3 0 -18.7 0 -18.4 -19 02/01/2005 00:10:00 8.2 0.7 9.5 6.5 8.2 0.8 9.9 6.1 0.4 0 0.4 0.4 38 5 29 305 4 0 5 0 -18.8 0 -18.4 -19 02/01/2005 00:20:00 7.6 0.8 9.1 5.3 7.5 0.8 9.9 5.7 0.4 0 0.4 0.4 32 6 44 305 4 0 5 0 -18.7 0 -18.4 -19 02/01/2005 00:30:00 7.9 1 9.9 5.7 7.7 1 9.9 5.7 0.4 0 0.4 0.4 26 6 26 305 4 0 4 0 -18.8 0.1 -18.4 -19 02/01/2005 00:40:00 8.7 1 11.1 6.1 8.5 1.1 10.7 6.1 0.4 0 0.4 0.4 33 6 31 305 4 0 4 0 -19 0 -19 -19.2 02/01/2005 00:50:00 8.7 1 10.7 6.1 8.6 1 10.7 6.1 0.4 0 0.4 0.4 31 6 32 305 4 0 4 0 -19 0 -18.8 -19 02/01/2005 01:00:00 8.6 0.8 11.1 6.5 8.6 0.8 11.5 6.8 0.4 0 0.4 0.4 27 6 27 305 4 0 4 0 -19 0 -19 -19.2 02/01/2005 01:10:00 8.9 0.9 10.7 6.1 8.8 1 11.1 6.5 0.4 0 0.4 0.4 31 6 30 305 4 0 4 0 -19.1 0 -19 -19.3 02/01/2005 01:20:00 9.2 0.8 11.1 6.5 9.1 0.8 11.1 6.5 0.4 0 0.4 0.4 30 5 29 305 4 0 4 0 -19.1 0 -19 -19.2 02/01/2005 01:30:00 8.9 1 11.1 6.5 8.7 1.1 11.1 6.5 0.4 0 0.4 0.4 34 5 36 305 4 0 4 0 -19.2 0 -19 -19.5 02/01/2005 01:40:00 8.7 0.7 9.9 6.5 8.6 0.7 9.9 6.5 0.4 0 0.4 0.4 32 4 27 305 4 0 4 0 -19.2 0 -19 -19.5 02/01/2005 01:50:00 8.8 1.1 11.1 5.7 8.8 1.1 11.1 5.7 0.4 0 0.4 0.4 33 5 31 305 4 0 4 0 -19.3 0 -19 -19.5 02/01/2005 02:00:00 8.2 0.8 9.9 6.5 8.1 0.9 9.9 5.7 0.4 0 0.4 0.4 29 5 32 305 4 0 4 0 -19.4 0 -19.2 -19.5 02/01/2005 02:10:00 8.4 0.7 9.9 6.5 8.4 0.7 9.9 6.1 0.4 0 0.4 0.4 25 5 18 305 4 0 4 0 -19.4 0.1 -19 -19.5 02/01/2005 02:20:00 7.7 1 9.5 5.3 7.5 1 9.5 5.3 0.4 0 0.4 0.4 32 5 29 305 4 0 4 0 -19.5 0 -19.3 -19.5 02/01/2005 02:30:00 7.7 0.6 9.1 6.1 7.7 0.6 9.5 5.7 0.4 0 0.4 0.4 32 4 38 305 4 0 4 0 -19.6 0 -19 -19.5 02/01/2005 02:40:00 7.7 0.5 8.8 6.1 7.6 0.6 8.8 6.1 0.4 0 0.4 0.4 30 9 27 305 3 0 4 0 -19.7 0.1 -19.5 -20.1 02/01/2005 02:50:00 7.5 0.7 9.5 5.7 7.5 0.7 9.5 5.3 0.4 0 0.4 0.4 28 4 31 305 3 0 3 0 -20.1 0.1 -19.9 -20.4 02/01/2005 03:00:00 7.5 0.5 8.8 6.1 7.5 0.6 8.8 5.7 0.4 0 0.4 0.4 26 6 20 305 3 0 3 0 -20.5 0 -20.2 -20.6 02/01/2005 03:10:00 8.2 0.4 9.5 6.8 8.2 0.5 9.9 6.8 0.4 0 0.4 0.4 30 3 26 305 3 0 3 0 -20.5 0 -20.4 -20.8 02/01/2005 03:20:00 7.9 0.8 9.5 5.3 7.9 0.7 9.5 5.7 0.4 0 0.4 0.4 28 6 23 305 3 0 3 0 -20.4 0 -20.2 -20.6 02/01/2005 03:30:00 7.9 0.7 9.1 5.3 7.9 0.8 9.5 5.7 0.4 0 0.4 0.4 25 4 28 305 3 0 3 0 -20.6 0.1 -20.2 -20.8 02/01/2005 03:40:00 7.6 0.6 9.1 5.7 7.5 0.7 8.8 5.7 0.4 0 0.4 0.4 28 5 27 305 3 0 3 0 -20.7 0 -20.6 -20.8 02/01/2005 03:50:00 7.8 0.6 9.1 6.1 7.7 0.7 9.5 6.1 0.4 0 0.4 0.4 26 5 27 305 3 0 3 0 -20.8 0 -20.6 -21.1 02/01/2005 04:00:00 7.7 0.5 9.1 6.1 7.7 0.6 8.8 5.7 0.4 0 0.4 0.4 30 5 23 305 3 0 3 0 -20.9 0 -20.8 -21 02/01/2005 04:10:00 7.2 0.6 8.8 5.7 7.2 0.7 8.8 5.3 0.4 0 0.4 0.4 27 5 18 305 3 0 2 0 -20.9 0 -20.8 -21.1 02/01/2005 04:20:00 7.7 0.7 9.1 6.1 7.7 0.7 9.5 5.7 0.4 0 0.4 0.4 23 4 33 305 3 0 2 0 -21.1 0.1 -20.8 -21.3 02/01/2005 04:30:00 7.4 0.8 9.1 5.3 7.4 0.8 9.1 5.3 0.4 0 0.4 0.4 22 5 24 305 3 0 3 0 -21.1 0 -21 -21.3 02/01/2005 04:40:00 7.6 0.6 8.8 5.3 7.6 0.6 9.1 5.3 0.4 0 0.4 0.4 25 4 27 305 2 0 2 0 -21 0 -20.8 -21.3 02/01/2005 04:50:00 7.4 0.7 8.8 5.7 7.3 0.7 9.1 5.7 0.4 0 0.4 0.4 20 6 22 305 3 0 2 0 -21 0 -20.8 -21.1 02/01/2005 05:00:00 7.7 0.8 9.1 5.3 7.6 0.9 9.5 5.7 0.4 0 0.4 0.4 25 5 33 305 2 0 2 0 -21.1 0 -20.8 -21.3 02/01/2005 05:10:00 7.7 0.6 8.8 5.7 7.7 0.6 8.8 6.5 0.4 0 0.4 0.4 23 6 27 305 2 0 2 0 -21.3 0 -21.1 -21.5 02/01/2005 05:20:00 7.8 0.9 9.5 5.7 7.8 1 9.5 5.7 0.4 0 0.4 0.4 20 4 20 305 2 0 2 0 -21.4 0.1 -21.3 -21.7 02/01/2005 05:30:00 7.9 0.4 9.1 6.5 8 0.5 9.5 6.1 0.4 0 0.4 0.4 20 4 23 305 2 0 2 0 -21.5 0 -21.3 -21.7 02/01/2005 05:40:00 7.3 0.5 8.4 5.7 7.2 0.6 8.4 5.7 0.4 0 0.4 0.4 22 5 18 305 2 0 2 0 -21.5 0 -21.3 -21.7 02/01/2005 05:50:00 7 0.6 8.4 5.3 6.9 0.7 8.4 5.3 0.4 0 0.4 0.4 23 4 17 305 2 0 2 0 -21.4 0 -21.3 -21.5 02/01/2005 06:00:00 6.7 0.7 8 4.9 6.7 0.7 8 4.9 0.4 0 0.4 0.4 20 4 21 305 2 0 2 0 -21.4 0.1 -20.8 -21.7 02/01/2005 06:10:00 7.1 0.6 8.4 5.3 7 0.6 8.4 5.3 0.4 0 0.4 0.4 21 4 18 305 2 0 2 0 -21.3 0 -21.3 -21.3 02/01/2005 06:20:00 6.9 0.9 8.8 4.2 6.8 0.9 8.4 4.6 0.4 0 0.4 0.4 22 6 30 305 2 0 2 0 -21.2 0 -21.1 -21.3 02/01/2005 06:30:00 6.3 0.8 8.4 4.9 6.3 0.8 8.4 4.6 0.4 0 0.4 0.4 16 4 17 305 2 0 2 0 -21.2 0 -21 -21.3 02/01/2005 06:40:00 6.8 0.5 8.4 5.7 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 16 5 17 305 2 0 2 0 -21.1 0 -21 -21.3 02/01/2005 06:50:00 6.7 0.7 8.4 4.6 6.6 0.7 8.4 4.9 0.4 0 0.4 0.4 11 5 9 305 2 0 2 0 -21.1 0.1 -20.8 -21.3 02/01/2005 07:00:00 7.6 0.6 9.1 6.1 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 9 3 10 305 2 0 2 0 -21.2 0 -20.8 -21.3 02/01/2005 07:10:00 7.7 0.7 9.1 6.1 7.5 0.7 9.5 5.7 0.4 0 0.4 0.4 13 5 9 305 2 0 2 0 -21.3 0 -21.1 -21.3 02/01/2005 07:20:00 7.3 0.7 8.8 5.3 7.2 0.8 8.8 4.9 0.4 0 0.4 0.4 12 4 14 305 2 0 2 0 -21.3 0 -21.1 -21.3 02/01/2005 07:30:00 7 0.6 8.4 4.9 7 0.6 8.4 4.9 0.4 0 0.4 0.4 11 4 11 305 2 0 2 0 -21.3 0 -21.1 -21.3 02/01/2005 07:40:00 7.3 0.6 9.1 5.7 7.2 0.7 9.1 5.7 0.4 0 0.4 0.4 9 3 5 305 2 0 2 0 -21.2 0 -21.1 -21.3 02/01/2005 07:50:00 7.2 0.6 8.8 5.3 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 11 4 14 305 2 0 2 0 -21.2 0 -21 -21.3 02/01/2005 08:00:00 8 0.8 9.9 6.1 7.9 0.9 9.9 5.7 0.4 0 0.4 0.4 13 3 12 305 2 0 2 0 -21.2 0 -21.1 -21.3 02/01/2005 08:10:00 7.4 0.7 9.1 5.3 7.4 0.7 8.8 5.3 0.4 0 0.4 0.4 13 5 8 305 2 0 2 0 -21.2 0 -21.1 -21.3 02/01/2005 08:20:00 8.1 0.6 9.5 6.5 8.1 0.6 9.9 6.5 0.4 0 0.4 0.4 14 4 13 305 2 0 2 0 -21.2 0 -21.1 -21.3 02/01/2005 08:30:00 7.8 1 9.5 5.3 7.8 1 9.9 5.7 0.4 0 0.4 0.4 14 4 16 305 2 0 2 0 -21.2 0 -21 -21.3 02/01/2005 08:40:00 7.4 0.9 9.9 5.7 7.3 0.8 9.5 5.7 0.4 0 0.4 0.4 13 4 12 305 2 0 2 0 -21.2 0 -21 -21.3 02/01/2005 08:50:00 7.9 0.7 10.3 6.1 7.8 0.7 10.3 6.1 0.4 0 0.4 0.4 15 5 11 305 2 0 2 0 -21.1 0 -21 -21.3 02/01/2005 09:00:00 8.5 0.7 10.3 6.5 8.5 0.8 10.3 6.5 0.4 0 0.4 0.4 15 4 15 305 2 0 2 0 -21.1 0 -21 -21.3 02/01/2005 09:10:00 7.9 1 9.9 5.3 7.8 1 9.9 5.3 0.4 0 0.4 0.4 15 4 14 305 2 0 2 0 -21 0 -20.8 -21.1 02/01/2005 09:20:00 8.8 0.6 10.3 7.2 8.6 0.7 9.9 6.5 0.4 0 0.4 0.4 15 5 13 305 2 0 2 0 -21 0 -20.8 -21.1 02/01/2005 09:30:00 8.9 0.8 10.7 6.5 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 13 4 12 305 2 0 2 0 -20.9 0 -20.8 -21 02/01/2005 09:40:00 8.2 0.7 9.5 6.1 8.2 0.7 9.9 6.1 0.4 0 0.4 0.4 11 3 10 305 2 0 2 0 -20.8 0 -20.8 -21 02/01/2005 09:50:00 8.2 0.7 9.9 6.1 8.1 0.7 9.5 6.1 0.4 0 0.4 0.4 11 3 11 305 2 0 2 0 -20.8 0 -20.8 -21 02/01/2005 10:00:00 8.7 0.9 10.7 6.1 8.6 0.9 10.7 6.1 0.4 0 0.4 0.4 10 5 10 305 2 0 2 0 -20.8 0 -20.6 -21 02/01/2005 10:10:00 7.9 0.7 9.5 6.1 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 16 4 17 305 2 0 2 0 -20.7 0 -20.1 -20.8 02/01/2005 10:20:00 7.3 0.7 9.1 5.7 7.2 0.7 8.8 5.3 0.4 0 0.4 0.4 13 4 7 305 2 0 2 0 -20.7 0 -20.8 -20.8 02/01/2005 10:30:00 8.2 0.7 9.9 6.1 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 13 4 12 305 2 0 2 0 -20.7 0 -20.1 -20.8 02/01/2005 10:40:00 7.6 0.6 9.1 6.5 7.5 0.6 9.1 6.5 0.4 0 0.4 0.4 14 4 9 305 2 0 2 0 -20.7 0 -20.2 -20.8 02/01/2005 10:50:00 7.8 0.7 9.5 6.1 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 13 5 7 305 2 0 2 0 -20.7 0 -20.8 -21 02/01/2005 11:00:00 8.6 0.6 10.3 6.8 8.5 0.6 9.9 6.5 0.4 0 0.4 0.4 12 4 6 305 2 0 2 0 -20.7 0 -20.6 -20.8 02/01/2005 11:10:00 8.3 0.6 10.3 6.5 8.3 0.6 9.9 6.8 0.4 0 0.4 0.4 13 5 10 305 2 0 3 0 -20.6 0 -20.4 -20.8 02/01/2005 11:20:00 8.7 0.9 11.1 6.1 8.6 0.9 10.7 6.1 0.4 0 0.4 0.4 10 4 5 305 2 0 2 0 -20.7 0 -20.6 -20.8 02/01/2005 11:30:00 8.4 0.7 9.9 6.5 8.3 0.7 10.3 6.1 0.4 0 0.4 0.4 10 5 1 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/01/2005 11:40:00 7.6 1 9.9 4.9 7.6 1 9.5 4.9 0.4 0 0.4 0.4 10 5 8 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/01/2005 11:50:00 8.2 0.7 9.9 6.8 8 0.7 10.3 6.1 0.4 0 0.4 0.4 15 6 8 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/01/2005 12:00:00 8 0.6 9.9 6.5 8 0.7 9.9 6.5 0.4 0 0.4 0.4 17 5 17 305 2 0 2 0 -20.5 0 -20.2 -20.8 02/01/2005 12:10:00 8.3 1 10.7 5.7 8.3 0.9 9.9 6.1 0.4 0 0.4 0.4 14 4 21 305 3 0 2 0 -20.4 0 -20.1 -20.6 02/01/2005 12:20:00 8 0.7 9.9 6.5 7.9 0.7 9.9 5.7 0.4 0 0.4 0.4 13 5 18 305 3 0 3 0 -20.3 0 -20.1 -20.6 02/01/2005 12:30:00 8.6 0.8 10.7 6.5 8.5 0.8 10.7 6.5 0.4 0 0.4 0.4 16 4 18 305 3 0 2 0 -20.3 0 -20.1 -20.4 02/01/2005 12:40:00 7.8 0.7 9.5 6.1 7.7 0.7 9.5 6.5 0.4 0 0.4 0.4 14 5 11 305 3 0 2 0 -20.2 0 -20.1 -20.4 02/01/2005 12:50:00 8 0.8 10.3 5.7 7.9 0.9 9.9 5.7 0.4 0 0.4 0.4 12 5 12 305 3 0 3 0 -20 0 -19.7 -20.1 02/01/2005 13:00:00 8.8 1.2 12.2 6.5 8.7 1.2 12.2 6.5 0.4 0 0.4 0.4 13 5 9 305 3 0 3 0 -19.7 0 -19.5 -20.1 02/01/2005 13:10:00 9.6 1 11.8 7.2 9.5 1.1 11.8 7.2 0.4 0 0.4 0.4 14 4 11 305 3 0 3 0 -19.6 0 -19.3 -19.9 02/01/2005 13:20:00 10.2 0.9 12.6 7.2 10.1 1 13 7.6 0.4 0 0.4 0.4 14 4 11 305 3 0 3 0 -19.5 0.1 -19.2 -19.5 02/01/2005 13:30:00 10.2 0.7 11.8 8.4 10.2 0.7 11.8 8.4 0.4 0 0.4 0.4 15 4 16 305 3 0 3 0 -19.4 0.1 -19 -19.5 02/01/2005 13:40:00 10.3 1 13.3 7.6 10.2 1 12.6 7.2 0.4 0 0.4 0.4 15 5 24 305 3 0 3 0 -19.4 0 -19 -19.5 02/01/2005 13:50:00 10.1 1.1 13 7.6 10.1 1.1 13.3 7.6 0.4 0 0.4 0.4 14 5 9 305 3 0 3 0 -19.4 0 -19 -19.5 02/01/2005 14:00:00 10.6 0.9 12.6 7.6 10.5 1 12.6 8 0.4 0 0.4 0.4 16 5 13 305 3 0 3 0 -19.4 0 -19 -19.5 02/01/2005 14:10:00 10.6 1 12.6 7.6 10.5 1 13 7.6 0.4 0 0.4 0.4 17 5 0 305 3 0 3 0 -19.4 0 -19 -19.5 02/01/2005 14:20:00 9.9 1 12.6 7.6 9.7 1 12.6 7.2 0.4 0 0.4 0.4 21 5 21 305 3 0 3 0 -19.3 0 -19 -19.5 02/01/2005 14:30:00 10.4 1 13 8 10.3 1.1 13 7.6 0.4 0 0.4 0.4 22 5 21 305 3 0 3 0 -19.1 0 -19 -19.2 02/01/2005 14:40:00 9.8 1.2 13 6.8 9.6 1.2 12.6 7.2 0.4 0 0.4 0.4 21 5 18 305 3 0 3 0 -19.1 0 -18.8 -19.2 02/01/2005 14:50:00 10.1 1 11.8 7.2 10 1 12.6 7.6 0.4 0 0.4 0.4 18 5 14 305 3 0 3 0 -19.1 0 -18.8 -19.2 02/01/2005 15:00:00 10.2 1 12.6 8 10.1 1 12.6 7.6 0.4 0 0.4 0.4 18 5 18 305 3 0 3 0 -19.1 0 -18.8 -19.2 02/01/2005 15:10:00 10.7 0.8 12.6 8.8 10.7 0.8 13 8.8 0.4 0 0.4 0.4 18 4 23 305 3 0 3 0 -19.1 0 -18.6 -19 02/01/2005 15:20:00 9.8 0.8 11.5 7.6 9.7 0.9 11.8 7.2 0.4 0 0.4 0.4 19 4 17 305 3 0 3 0 -19 0 -18.8 -19 02/01/2005 15:30:00 9.8 0.7 11.1 7.6 9.6 0.8 11.5 7.6 0.4 0 0.4 0.4 20 4 18 305 3 0 3 0 -19 0 -18.6 -19 02/01/2005 15:40:00 8.6 0.8 10.3 6.5 8.5 0.8 10.3 6.8 0.4 0 0.4 0.4 21 5 19 305 3 0 3 0 -18.9 0.1 -18.4 -19 02/01/2005 15:50:00 8 0.8 10.3 6.1 8 0.7 9.9 6.1 0.4 0 0.4 0.4 20 5 16 305 3 0 4 0 -18.8 0 -18.4 -19 02/01/2005 16:00:00 10.1 0.8 12.2 8 10 0.9 13 7.6 0.4 0 0.4 0.4 18 4 13 305 3 0 4 0 -18.8 0 -18.4 -19 02/01/2005 16:10:00 10.7 1 13 8.4 10.6 1 13.3 8.4 0.4 0 0.4 0.4 20 5 24 305 3 0 4 0 -18.9 0.1 -18.4 -19 02/01/2005 16:20:00 10.9 0.8 12.6 8.8 10.7 0.9 13 8.8 0.4 0 0.4 0.4 20 4 16 305 3 0 3 0 -18.9 0 -18.4 -19 02/01/2005 16:30:00 10.4 1 13.7 8.4 10.3 1 13.7 8 0.4 0 0.4 0.4 18 5 22 305 3 0 3 0 -18.8 0 -18.4 -19 02/01/2005 16:40:00 10.8 1 13.7 8.4 10.6 1 13.3 7.6 0.4 0 0.4 0.4 20 5 19 305 3 0 3 0 -18.7 0 -18.4 -18.8 02/01/2005 16:50:00 10.8 1.1 13 8.4 10.6 1 13 8 0.4 0 0.4 0.4 16 5 16 305 3 0 3 0 -18.6 0 -18.2 -18.8 02/01/2005 17:00:00 10.4 1.2 13.3 8 10.1 1.2 13 7.6 0.4 0 0.4 0.4 15 5 9 305 3 0 3 0 -18.6 0 -18.2 -18.8 02/01/2005 17:10:00 10.8 1 13 7.6 10.6 1 13 8 0.4 0 0.4 0.4 18 4 18 305 3 0 3 0 -18.7 0 -18.4 -18.8 02/01/2005 17:20:00 10.7 1.1 13 8 10.5 1.1 13.7 8 0.4 0 0.4 0.4 18 5 16 305 3 0 3 0 -18.7 0 -18.4 -18.8 02/01/2005 17:30:00 9.8 1.1 12.2 7.2 9.6 1.1 12.6 7.2 0.4 0 0.4 0.4 18 5 23 305 3 0 3 0 -18.7 0 -18.4 -18.8 02/01/2005 17:40:00 10.5 1 12.6 8 10.5 1 13.3 7.6 0.4 0 0.4 0.4 19 5 17 305 3 0 3 0 -18.7 0 -18.4 -18.8 02/01/2005 17:50:00 9.9 0.9 12.2 7.6 9.9 0.9 13 7.2 0.4 0 0.4 0.4 18 5 16 305 3 0 3 0 -18.7 0 -18.4 -19 02/01/2005 18:00:00 10.3 1 12.6 7.6 10.2 1.1 12.6 6.8 0.4 0 0.4 0.4 17 5 18 305 3 0 3 0 -18.7 0.1 -18.4 -19 02/01/2005 18:10:00 10.2 1.2 13 7.6 10 1.2 13.3 7.6 0.4 0 0.4 0.4 18 5 21 305 3 0 3 0 -19 0.1 -18.4 -19 02/01/2005 18:20:00 10.6 1 13.3 8.4 10.4 1 13.3 8.4 0.4 0 0.4 0.4 18 5 17 305 3 0 3 0 -19 0 -18.8 -19 02/01/2005 18:30:00 10.9 1 13 8 10.7 1.1 13 7.6 0.4 0 0.4 0.4 17 5 9 305 3 0 3 0 -18.9 0 -18.6 -19 02/01/2005 18:40:00 11.4 1 14.1 8.8 11.2 1 13.3 8.4 0.4 0 0.4 0.4 16 4 18 305 3 0 3 0 -19.1 0 -18.8 -19.2 02/01/2005 18:50:00 11.3 0.9 13.3 8.4 11.1 1 13.3 8.4 0.4 0 0.4 0.4 16 4 18 305 3 0 3 0 -19.2 0 -19 -19.3 02/01/2005 19:00:00 10.6 1 13 8 10.5 1.1 13.3 7.6 0.4 0 0.4 0.4 16 4 19 305 3 0 3 0 -19.2 0 -19 -19.3 02/01/2005 19:10:00 10.7 0.9 12.6 8.4 10.7 0.9 13 8.4 0.4 0 0.4 0.4 15 4 17 305 3 0 3 0 -19.2 0 -19 -19.3 02/01/2005 19:20:00 10.9 1.2 13.3 8 10.7 1.2 13.7 7.6 0.4 0 0.4 0.4 18 5 14 305 3 0 3 0 -19.1 0 -18.8 -19.2 02/01/2005 19:30:00 10.8 1 13.7 8.4 10.7 1 14.5 8.4 0.4 0 0.4 0.4 17 5 25 305 3 0 3 0 -19.1 0 -19 -19.3 02/01/2005 19:40:00 11.1 1 13.7 8.4 11.1 1.1 14.1 8 0.4 0 0.4 0.4 13 5 11 305 3 0 3 0 -19.3 0.1 -19 -19.5 02/01/2005 19:50:00 10.9 1.3 13.7 7.6 10.8 1.3 13.7 7.6 0.4 0 0.4 0.4 16 5 19 305 3 0 3 0 -19.5 0.1 -19.2 -19.5 02/01/2005 20:00:00 10.4 1 12.2 7.6 10.3 1.1 12.6 7.2 0.4 0 0.4 0.4 17 5 14 305 3 0 3 0 -19.4 0 -19.3 -19.5 02/01/2005 20:10:00 10.1 1.1 12.6 7.6 10.1 1.1 12.6 7.6 0.4 0 0.4 0.4 13 6 9 305 3 0 3 0 -19.4 0 -19.3 -19.5 02/01/2005 20:20:00 9.8 0.9 12.2 6.8 9.6 1 12.2 6.8 0.4 0 0.4 0.4 15 5 11 305 3 0 3 0 -19.5 0 -19.3 -19.5 02/01/2005 20:30:00 10.3 0.9 12.2 7.6 10.2 1 12.6 8 0.4 0 0.4 0.4 20 5 19 305 3 0 3 0 -19.5 0 -19.3 -19.5 02/01/2005 20:40:00 10.2 1 12.6 8 10 1 12.2 7.6 0.4 0 0.4 0.4 19 5 26 305 3 0 3 0 -19.6 0 -19.5 -19.5 02/01/2005 20:50:00 10.8 0.8 12.6 8.8 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 20 5 24 305 3 0 3 0 -19.6 0 -19.5 -19.7 02/01/2005 21:00:00 11.1 0.8 13 9.1 11 0.9 13 8.8 0.4 0 0.4 0.4 17 4 8 305 3 0 3 0 -19.6 0 -19.3 -19.7 02/01/2005 21:10:00 11.1 0.8 13 8.8 11 0.8 13.3 8.8 0.4 0 0.4 0.4 14 4 14 305 3 0 3 0 -19.5 0 -19.3 -19.5 02/01/2005 21:20:00 10.6 0.7 12.2 8.8 10.6 0.8 13 8.4 0.4 0 0.4 0.4 16 4 15 305 3 0 3 0 -19.6 0 -19.3 -19.7 02/01/2005 21:30:00 10.9 0.9 13 8.8 10.7 1 12.6 7.6 0.4 0 0.4 0.4 15 4 16 305 3 0 3 0 -19.6 0 -19.3 -19.5 02/01/2005 21:40:00 10.2 1.1 12.6 7.2 10.1 1.1 12.6 7.6 0.4 0 0.4 0.4 15 5 13 305 3 0 3 0 -19.4 0 -19.2 -19.5 02/01/2005 21:50:00 9.4 1 12.2 6.8 9.3 1 11.8 7.2 0.4 0 0.4 0.4 15 5 22 305 3 0 3 0 -19.5 0 -19.3 -19.5 02/01/2005 22:00:00 9.7 0.8 11.8 7.2 9.6 0.9 11.5 6.8 0.4 0 0.4 0.4 14 4 14 305 3 0 3 0 -19.7 0 -19.5 -19.9 02/01/2005 22:10:00 8.8 1.1 11.1 6.1 8.7 1.1 11.1 6.1 0.4 0 0.4 0.4 13 5 18 305 3 0 3 0 -19.8 0 -19.5 -20.1 02/01/2005 22:20:00 9.1 0.9 11.1 7.2 9 0.8 11.1 6.8 0.4 0 0.4 0.4 16 4 17 305 3 0 3 0 -19.9 0 -19.5 -20.1 02/01/2005 22:30:00 9.1 0.8 11.1 6.8 8.9 1 10.7 6.5 0.4 0 0.4 0.4 12 4 18 305 3 0 3 0 -19.8 0 -19.5 -20.1 02/01/2005 22:40:00 8.9 0.9 10.7 6.8 8.9 0.9 10.7 6.8 0.4 0 0.4 0.4 16 5 18 305 3 0 2 0 -19.9 0 -19.7 -20.1 02/01/2005 22:50:00 8.2 0.8 10.7 6.1 8 0.8 9.9 6.1 0.4 0 0.4 0.4 13 5 10 305 3 0 2 0 -20 0 -19.7 -20.1 02/01/2005 23:00:00 7.9 1 10.3 5.7 7.9 1 10.3 6.1 0.4 0 0.4 0.4 12 5 7 305 3 0 2 0 -19.9 0 -19.5 -20.1 02/01/2005 23:10:00 8.2 0.8 9.9 6.5 8.1 0.8 10.3 6.1 0.4 0 0.4 0.4 9 6 4 305 3 0 2 0 -19.9 0 -19.7 -20.1 02/01/2005 23:20:00 9.4 1 11.5 6.5 9.2 1.2 12.2 6.1 0.4 0 0.4 0.4 11 4 5 305 3 0 2 0 -20 0 -19.7 -20.1 02/01/2005 23:30:00 8.7 0.9 10.3 6.1 8.6 0.9 10.3 6.5 0.4 0 0.4 0.4 15 5 13 305 3 0 2 0 -20.1 0 -19.9 -20.1 02/01/2005 23:40:00 8.4 0.9 11.1 6.1 8.3 0.9 11.1 6.1 0.4 0 0.4 0.4 13 5 16 305 3 0 3 0 -20.1 0 -19.9 -20.1 02/01/2005 23:50:00 8.9 0.9 10.7 6.1 8.8 0.9 11.1 6.5 0.4 0 0.4 0.4 14 5 10 305 3 0 2 0 -20.1 0 -19.9 -20.1 02/02/2005 00:00:00 8.5 0.9 10.3 6.1 8.4 0.8 10.3 6.1 0.4 0 0.4 0.4 12 4 7 305 2 0 3 0 -20.1 0 -19.9 -20.1 02/02/2005 00:10:00 8.3 0.6 9.5 6.5 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 18 4 14 305 2 0 2 0 -20.1 0 -19.9 -20.1 02/02/2005 00:20:00 8.5 0.8 11.1 6.5 8.4 0.9 10.7 6.5 0.4 0 0.4 0.4 15 5 10 305 2 0 2 0 -20.2 0 -20.1 -20.1 02/02/2005 00:30:00 9 1.1 11.1 6.5 8.8 1.1 11.1 6.1 0.4 0 0.4 0.4 13 6 17 305 2 0 2 0 -20.1 0 -19.9 -20.1 02/02/2005 00:40:00 9.5 1 11.8 7.2 9.3 1 11.8 7.2 0.4 0 0.4 0.4 16 5 18 305 2 0 2 0 -20 0 -19.7 -20.1 02/02/2005 00:50:00 8.6 1.1 11.8 6.1 8.4 1.1 11.8 6.1 0.4 0 0.4 0.4 20 6 14 305 3 0 2 0 -19.8 0 -19.5 -20.1 02/02/2005 01:00:00 7.8 0.9 10.7 5.7 7.7 0.9 10.7 5.7 0.4 0 0.4 0.4 20 6 18 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/02/2005 01:10:00 8.5 1 11.5 5.7 8.2 0.9 10.7 6.1 0.4 0 0.4 0.4 17 6 5 305 2 0 2 0 -19.8 0 -19.7 -20.1 02/02/2005 01:20:00 9.5 1.2 12.2 6.5 9.3 1.2 12.2 6.1 0.4 0 0.4 0.4 15 6 11 305 2 0 2 0 -19.8 0 -19.5 -19.9 02/02/2005 01:30:00 10.3 1.1 12.6 7.6 10.2 1.1 13 7.6 0.4 0 0.4 0.4 15 5 17 305 2 0 2 0 -19.7 0 -19.5 -20.1 02/02/2005 01:40:00 9 1 11.5 6.8 8.9 1.1 11.5 6.8 0.4 0 0.4 0.4 15 6 17 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 01:50:00 8.2 0.9 10.7 5.7 8.1 1 10.3 5.7 0.4 0 0.4 0.4 15 5 16 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 02:00:00 8.4 1 11.1 6.1 8.3 1 11.1 6.1 0.4 0 0.4 0.4 13 6 19 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 02:10:00 8.6 1.2 11.1 6.1 8.3 1.2 10.7 5.3 0.4 0 0.4 0.4 10 8 15 305 2 0 2 0 -19.6 0 -19.5 -19.7 02/02/2005 02:20:00 9.6 1.2 12.2 6.8 9.6 1.1 12.2 6.8 0.4 0 0.4 0.4 6 5 4 305 3 0 3 0 -19.5 0 -19.3 -19.5 02/02/2005 02:30:00 9.6 0.9 11.5 7.2 9.5 1 11.5 6.8 0.4 0 0.4 0.4 7 5 3 305 3 0 2 0 -19.5 0 -19.3 -19.5 02/02/2005 02:40:00 9.6 0.9 11.5 6.5 9.5 0.9 12.2 6.8 0.4 0 0.4 0.4 8 5 9 305 3 0 2 0 -19.5 0 -19.2 -19.5 02/02/2005 02:50:00 9 1.2 11.8 5.7 8.8 1.3 12.2 5.3 0.4 0 0.4 0.4 7 5 7 305 2 0 2 0 -19.5 0 -19.3 -19.7 02/02/2005 03:00:00 9 0.8 11.1 6.8 9 0.8 11.1 6.8 0.4 0 0.4 0.4 6 5 9 305 2 0 3 0 -19.5 0 -19.2 -19.5 02/02/2005 03:10:00 8.2 1.2 11.1 5.7 8.2 1.2 11.5 5.7 0.4 0 0.4 0.4 7 5 359 305 2 0 2 0 -19.4 0 -19.2 -19.5 02/02/2005 03:20:00 7.8 1.1 10.3 5.3 7.8 1.1 10.3 5.3 0.4 0 0.4 0.4 9 6 12 305 2 0 2 0 -19.4 0 -19.2 -19.5 02/02/2005 03:30:00 8.3 0.8 10.3 6.5 8.3 0.8 10.7 6.1 0.4 0 0.4 0.4 7 6 6 305 2 0 2 0 -19.4 0.1 -19 -19.5 02/02/2005 03:40:00 8.9 0.9 11.1 6.1 8.8 0.9 10.7 6.5 0.4 0 0.4 0.4 7 5 5 305 2 0 2 0 -19.5 0 -19.2 -19.5 02/02/2005 03:50:00 8.3 0.8 11.1 6.5 8.3 0.8 11.1 6.1 0.4 0 0.4 0.4 9 5 6 305 2 0 2 0 -19.5 0 -19.3 -19.5 02/02/2005 04:00:00 7.3 0.6 8.8 6.1 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 11 4 11 305 2 0 2 0 -19.4 0 -19.3 -19.5 02/02/2005 04:10:00 7 0.6 8.4 5.7 7 0.6 8.8 5.3 0.4 0 0.4 0.4 12 4 11 305 2 0 2 0 -19.5 0 -19.3 -19.5 02/02/2005 04:20:00 5.8 0.6 7.2 4.2 5.8 0.7 7.6 4.2 0.4 0 0.4 0.4 11 4 7 305 2 0 2 0 -19.5 0 -19.3 -19.5 02/02/2005 04:30:00 5.3 0.6 7.6 4.2 5.1 0.5 7.6 4.2 0.4 0 0.4 0.4 1 5 358 305 2 0 2 0 -19.6 0 -19.5 -19.7 02/02/2005 04:40:00 6 0.7 8 4.2 5.8 0.8 7.6 3.8 0.4 0 0.4 0.4 3 5 4 305 2 0 2 0 -19.4 0 -19.2 -19.5 02/02/2005 04:50:00 6.1 0.7 8 4.6 5.9 0.7 8 4.2 0.4 0 0.4 0.4 7 5 9 305 2 0 2 0 -19.4 0 -19.2 -19.5 02/02/2005 05:00:00 6 0.6 7.2 4.6 5.7 0.5 7.2 4.2 0.4 0 0.4 0.4 8 5 356 305 2 0 2 0 -19.3 0 -19.2 -19.5 02/02/2005 05:10:00 5.8 0.7 7.6 4.2 5.6 0.8 7.6 3.8 0.4 0 0.4 0.4 11 5 15 305 2 0 2 0 -19.2 0 -19 -19.5 02/02/2005 05:20:00 5.8 0.6 7.2 4.2 5.6 0.7 7.2 3.8 0.4 0 0.4 0.4 10 5 9 305 2 0 2 0 -19.1 0 -19 -19.2 02/02/2005 05:30:00 5.3 0.5 6.8 3.8 5 0.5 6.5 3.8 0.4 0 0.4 0.4 7 6 12 305 2 0 2 0 -19.1 0 -19 -19.2 02/02/2005 05:40:00 5.8 0.7 8 4.2 5.7 0.7 8.4 4.2 0.4 0 0.4 0.4 4 7 341 305 2 0 2 0 -19.1 0 -19 -19.2 02/02/2005 05:50:00 6.5 0.6 8 4.9 6.3 0.6 7.6 4.9 0.4 0 0.4 0.4 6 5 356 305 2 0 2 0 -18.9 0 -18.6 -19 02/02/2005 06:00:00 6.4 0.7 8 4.6 6.2 0.7 7.6 4.6 0.4 0 0.4 0.4 6 5 11 305 2 0 2 0 -18.7 0 -18.4 -19 02/02/2005 06:10:00 5.5 0.5 6.8 4.2 5.3 0.6 6.8 3.8 0.4 0 0.4 0.4 0 5 0 305 2 0 2 0 -18.6 0.1 -18.2 -18.8 02/02/2005 06:20:00 6.6 1 9.9 4.6 6.4 1 8.8 4.6 0.4 0 0.4 0.4 351 6 358 305 3 0 2 0 -18.1 0.3 -17.5 -18.4 02/02/2005 06:30:00 7.3 0.9 10.7 5.7 7.2 0.9 10.7 5.3 0.4 0 0.4 0.4 344 6 341 305 3 0 3 0 -17.5 0.1 -17.1 -17.9 02/02/2005 06:40:00 7.4 1 9.9 5.3 7.3 0.9 9.9 5.3 0.4 0 0.4 0.4 340 7 347 305 3 0 3 0 -17.4 0 -16.9 -17.7 02/02/2005 06:50:00 8.2 1 10.7 6.1 8.2 1.1 11.1 5.7 0.4 0 0.4 0.4 347 6 347 305 3 0 3 0 -17.2 0.1 -16.9 -17.5 02/02/2005 07:00:00 8.1 1.2 10.3 4.9 8.1 1.2 10.7 4.6 0.4 0 0.4 0.4 352 7 350 305 3 0 3 0 -17.2 0 -16.9 -17.3 02/02/2005 07:10:00 6.6 0.8 8.4 4.6 6.6 0.9 9.1 4.2 0.4 0 0.4 0.4 358 6 358 305 3 0 3 0 -17.4 0 -16.9 -17.5 02/02/2005 07:20:00 7.2 1.1 9.9 4.6 7.2 1.1 9.9 4.6 0.4 0 0.4 0.4 359 8 347 305 3 0 3 0 -17.3 0.1 -16.9 -17.5 02/02/2005 07:30:00 7.7 0.9 9.9 5.3 7.6 1 9.9 5.7 0.4 0 0.4 0.4 359 7 357 305 3 0 3 0 -17.3 0.1 -16.9 -17.5 02/02/2005 07:40:00 7.5 0.8 9.9 4.9 7.4 0.8 9.5 5.3 0.4 0 0.4 0.4 4 6 7 305 3 0 3 0 -17.4 0 -16.9 -17.5 02/02/2005 07:50:00 7.8 1.3 11.8 5.3 7.7 1.4 11.8 4.6 0.4 0 0.4 0.4 357 9 343 305 3 0 3 0 -17.4 0.1 -16.9 -17.7 02/02/2005 08:00:00 8.1 1.3 11.5 4.9 8 1.2 11.5 5.3 0.4 0 0.4 0.4 357 6 347 305 3 0 3 0 -17.2 0 -16.9 -17.5 02/02/2005 08:10:00 8.8 0.9 11.5 6.5 8.7 1 11.5 5.7 0.4 0 0.4 0.4 1 6 348 305 3 0 3 0 -17.2 0 -16.9 -17.3 02/02/2005 08:20:00 8.3 0.8 10.3 6.5 8.3 0.8 10.3 6.1 0.4 0 0.4 0.4 3 5 4 305 3 0 3 0 -17.3 0.1 -16.9 -17.5 02/02/2005 08:30:00 7.9 1 10.3 5.7 7.9 0.9 9.9 5.7 0.4 0 0.4 0.4 4 6 9 305 3 0 3 0 -17.2 0 -16.9 -17.3 02/02/2005 08:40:00 7.9 0.9 9.9 4.9 7.7 0.8 9.9 5.3 0.4 0 0.4 0.4 5 6 1 305 3 0 3 0 -17.3 0 -17.1 -17.5 02/02/2005 08:50:00 7 1.1 10.3 4.9 6.9 1.2 10.7 4.9 0.4 0 0.4 0.4 9 6 10 305 3 0 3 0 -17.4 0.1 -16.9 -17.5 02/02/2005 09:00:00 6.9 0.7 9.1 4.9 6.8 0.7 9.5 4.9 0.4 0 0.4 0.4 11 5 3 305 3 0 3 0 -17.5 0 -16.9 -17.7 02/02/2005 09:10:00 6.9 0.7 8.8 5.3 6.8 0.7 8.8 5.3 0.4 0 0.4 0.4 15 5 8 305 3 0 3 0 -17.7 0.1 -17.5 -18.1 02/02/2005 09:20:00 6.4 0.9 8.4 4.2 6.3 0.9 8.8 4.2 0.4 0 0.4 0.4 14 5 15 305 3 0 3 0 -17.9 0 -17.7 -18.1 02/02/2005 09:30:00 5.7 0.5 7.2 4.2 5.7 0.5 6.8 4.2 0.4 0 0.4 0.4 23 5 23 305 3 0 3 0 -18.3 0.1 -17.9 -18.4 02/02/2005 09:40:00 6.3 0.5 8 4.9 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 21 5 14 305 3 0 3 0 -18.4 0 -18.2 -18.4 02/02/2005 09:50:00 5.8 0.6 7.6 4.6 5.7 0.6 8 4.6 0.4 0 0.4 0.4 19 5 8 305 3 0 3 0 -18.4 0 -18.2 -18.6 02/02/2005 10:00:00 6.3 0.5 7.6 4.9 6.1 0.5 7.6 4.6 0.4 0 0.4 0.4 24 5 16 305 3 0 3 0 -18.5 0 -18.4 -18.6 02/02/2005 10:10:00 6.8 0.7 9.5 5.3 6.6 0.7 9.5 4.9 0.4 0 0.4 0.4 23 5 12 305 3 0 3 0 -18.6 0 -18.4 -18.6 02/02/2005 10:20:00 6.2 0.7 8 4.6 6.1 0.7 8 4.2 0.4 0 0.4 0.4 19 5 11 305 3 0 3 0 -18.6 0 -18.4 -18.6 02/02/2005 10:30:00 6.9 0.9 9.1 4.9 6.8 0.8 9.1 4.9 0.4 0 0.4 0.4 11 7 12 305 3 0 3 0 -18.3 0.2 -18.1 -18.8 02/02/2005 10:40:00 7.6 1.1 10.7 5.3 7.7 1.2 11.1 5.3 0.4 0 0.4 0.4 4 5 4 305 3 0 3 0 -18 0 -17.9 -18.1 02/02/2005 10:50:00 9.1 0.9 11.1 6.8 9.1 1 11.5 6.5 0.4 0 0.4 0.4 2 5 358 305 3 0 3 0 -18 0 -17.7 -18.1 02/02/2005 11:00:00 9.4 0.9 11.8 6.8 9.4 0.9 11.5 6.8 0.4 0 0.4 0.4 4 5 4 305 3 0 3 0 -18.1 0 -17.9 -18.4 02/02/2005 11:10:00 9.6 0.9 11.8 7.2 9.6 0.9 11.8 7.2 0.4 0 0.4 0.4 5 5 8 305 3 0 3 0 -18.1 0 -17.9 -18.4 02/02/2005 11:20:00 9.5 1 11.8 6.5 9.5 1.1 12.2 6.8 0.4 0 0.4 0.4 6 4 9 305 3 0 3 0 -18.2 0 -18.1 -18.4 02/02/2005 11:30:00 8.4 1.1 12.2 6.1 8.4 1.1 12.2 6.1 0.4 0 0.4 0.4 14 5 16 305 3 0 3 0 -18.4 0.1 -18.1 -18.4 02/02/2005 11:40:00 9.9 1.3 12.2 6.8 9.8 1.2 12.6 6.8 0.4 0 0.4 0.4 13 5 17 305 3 0 3 0 -18.4 0.1 -18.1 -18.6 02/02/2005 11:50:00 8 0.9 10.7 6.1 8 0.9 10.7 6.1 0.4 0 0.4 0.4 20 6 19 305 3 0 4 0 -18.3 0.1 -18.1 -18.4 02/02/2005 12:00:00 10 0.7 11.8 7.6 10 0.8 11.8 7.6 0.4 0 0.4 0.4 16 4 23 305 3 0 3 0 -18.5 0 -18.1 -18.8 02/02/2005 12:10:00 9.5 0.8 11.1 7.6 9.4 0.8 11.5 6.8 0.4 0 0.4 0.4 20 6 11 305 3 0 3 0 -18.8 0.1 -18.4 -19 02/02/2005 12:20:00 9.6 1 11.8 6.8 9.4 1 11.8 6.8 0.4 0 0.4 0.4 17 4 16 305 3 0 3 0 -19 0 -18.6 -19 02/02/2005 12:30:00 9.5 0.9 11.5 7.2 9.4 0.9 11.8 7.6 0.4 0 0.4 0.4 16 4 14 305 3 0 3 0 -19.1 0 -18.8 -19.2 02/02/2005 12:40:00 9.4 0.8 11.5 7.6 9.4 0.8 11.1 7.2 0.4 0 0.4 0.4 17 4 18 305 3 0 3 0 -19.1 0 -19 -19.2 02/02/2005 12:50:00 9.7 0.9 11.5 6.8 9.6 1 11.5 6.5 0.4 0 0.4 0.4 16 4 16 305 3 0 3 0 -19.1 0 -18.8 -19.2 02/02/2005 13:00:00 9.5 0.7 11.1 7.2 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 17 5 19 305 3 0 3 0 -19.1 0 -19 -19.2 02/02/2005 13:10:00 8.7 1 11.1 6.5 8.6 1 11.1 6.1 0.4 0 0.4 0.4 20 7 15 305 3 0 3 0 -19.1 0 -19 -19.2 02/02/2005 13:20:00 9.2 0.9 10.7 6.5 9.1 0.9 10.7 6.1 0.4 0 0.4 0.4 22 4 22 305 3 0 3 0 -19.1 0 -19 -19.2 02/02/2005 13:30:00 9.2 0.5 10.3 7.6 9.1 0.6 10.7 7.2 0.4 0 0.4 0.4 21 4 22 305 3 0 3 0 -19.1 0 -19 -19.2 02/02/2005 13:40:00 8.6 0.6 9.9 6.8 8.6 0.6 9.9 6.5 0.4 0 0.4 0.4 20 7 19 305 3 0 3 0 -19.1 0 -19 -19.2 02/02/2005 13:50:00 8.3 0.8 10.3 6.1 8.2 0.8 9.9 6.5 0.4 0 0.4 0.4 21 5 29 305 3 0 3 0 -19 0 -19 -19 02/02/2005 14:00:00 8.4 0.6 9.5 6.5 8.4 0.6 9.5 6.1 0.4 0 0.4 0.4 18 5 19 305 3 0 3 0 -19.1 0 -19 -19.2 02/02/2005 14:10:00 8.4 0.6 10.3 6.5 8.4 0.6 10.3 6.8 0.4 0 0.4 0.4 17 5 22 305 3 0 3 0 -19 0 -19 -19 02/02/2005 14:20:00 8.1 0.6 9.5 6.1 8.1 0.7 9.5 6.1 0.4 0 0.4 0.4 20 5 24 305 3 0 3 0 -19 0 -18.8 -19 02/02/2005 14:30:00 8 0.7 9.9 6.1 7.9 0.8 9.9 6.1 0.4 0 0.4 0.4 19 8 14 305 3 0 3 0 -19 0 -18.8 -19 02/02/2005 14:40:00 7.8 0.7 9.1 6.1 7.8 0.8 9.5 5.7 0.4 0 0.4 0.4 20 7 13 305 3 0 3 0 -19.1 0 -19 -19.2 02/02/2005 14:50:00 8.3 1.1 10.7 5.7 8.2 1.1 10.7 5.7 0.4 0 0.4 0.4 15 6 8 305 3 0 3 0 -19.1 0 -19 -19.2 02/02/2005 15:00:00 8.7 1 10.7 6.1 8.8 0.9 11.5 6.5 0.4 0 0.4 0.4 13 5 8 305 3 0 3 0 -19.2 0 -19 -19.3 02/02/2005 15:10:00 9.4 0.6 11.1 7.2 9.4 0.7 11.1 7.6 0.4 0 0.4 0.4 16 5 18 305 3 0 3 0 -19.2 0 -19 -19.5 02/02/2005 15:20:00 8.6 1 11.5 6.5 8.7 1 11.1 6.1 0.4 0 0.4 0.4 17 6 17 305 3 0 3 0 -19.2 0 -19 -19.5 02/02/2005 15:30:00 9 0.9 10.7 6.1 8.9 1 11.1 6.5 0.4 0 0.4 0.4 16 7 23 305 3 0 3 0 -19.3 0 -19 -19.5 02/02/2005 15:40:00 8.9 0.9 11.5 6.5 8.9 0.9 11.5 6.8 0.4 0 0.4 0.4 19 5 18 305 3 0 3 0 -19.3 0 -19 -19.5 02/02/2005 15:50:00 8.6 0.8 11.1 6.1 8.6 0.8 10.3 6.5 0.4 0 0.4 0.4 14 5 7 305 3 0 3 0 -19.4 0.1 -19 -19.5 02/02/2005 16:00:00 8.6 0.9 10.3 6.1 8.6 1 10.7 6.1 0.4 0 0.4 0.4 12 4 12 305 3 0 3 0 -19.5 0 -19.2 -19.5 02/02/2005 16:10:00 9 1 10.7 6.5 9 1 11.1 6.5 0.4 0 0.4 0.4 14 4 11 305 3 0 3 0 -19.4 0 -19 -19.5 02/02/2005 16:20:00 9.1 0.7 10.7 7.6 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 16 5 13 305 3 0 3 0 -19.4 0 -19 -19.5 02/02/2005 16:30:00 8.8 0.6 9.9 6.8 8.8 0.6 10.3 6.8 0.4 0 0.4 0.4 17 4 13 305 3 0 3 0 -19.4 0 -19 -19.5 02/02/2005 16:40:00 9.2 0.6 10.7 7.2 9.3 0.6 10.7 7.6 0.4 0 0.4 0.4 13 3 15 305 3 0 3 0 -19.5 0.1 -19.2 -19.5 02/02/2005 16:50:00 9.4 0.6 10.7 7.6 9.4 0.6 10.7 7.2 0.4 0 0.4 0.4 14 3 13 305 3 0 3 0 -19.5 0 -19.2 -19.5 02/02/2005 17:00:00 8.6 0.7 9.9 6.5 8.7 0.8 10.3 5.7 0.4 0 0.4 0.4 13 4 14 305 3 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 17:10:00 8.1 0.7 9.5 6.1 8.1 0.7 9.9 6.1 0.4 0 0.4 0.4 12 4 11 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 17:20:00 7.5 0.9 9.5 5.3 7.4 0.9 9.9 5.3 0.4 0 0.4 0.4 14 5 14 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 17:30:00 7.3 0.7 9.1 5.7 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 13 4 14 305 3 0 2 0 -19.6 0 -19.5 -19.7 02/02/2005 17:40:00 7.5 0.7 9.5 6.1 7.5 0.8 9.5 5.7 0.4 0 0.4 0.4 14 5 5 305 2 0 2 0 -19.6 0 -19.5 -19.7 02/02/2005 17:50:00 8.2 0.9 9.9 5.7 8.2 0.9 10.3 6.1 0.4 0 0.4 0.4 19 5 21 305 2 0 2 0 -19.7 0 -19.5 -19.7 02/02/2005 18:00:00 8 0.7 9.5 5.7 7.9 0.7 9.5 5.7 0.4 0 0.4 0.4 16 3 12 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 18:10:00 8 0.8 9.9 5.7 7.9 0.8 9.9 5.7 0.4 0 0.4 0.4 16 4 9 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 18:20:00 8.2 0.6 9.9 6.5 8.1 0.7 9.9 6.1 0.4 0 0.4 0.4 20 5 18 305 2 0 2 0 -19.8 0 -19.5 -20.1 02/02/2005 18:30:00 8.4 0.8 10.3 6.5 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 20 4 20 305 2 0 2 0 -19.8 0 -19.7 -20.1 02/02/2005 18:40:00 8.9 0.8 11.1 6.8 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 22 4 22 305 2 0 2 0 -19.8 0 -19.5 -20.1 02/02/2005 18:50:00 8.8 0.9 10.7 6.5 8.6 0.9 10.3 6.1 0.4 0 0.4 0.4 19 4 18 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/02/2005 19:00:00 8 0.8 9.5 6.1 7.8 0.8 9.5 6.1 0.4 0 0.4 0.4 16 4 16 305 2 0 2 0 -19.9 0 -19.5 -20.1 02/02/2005 19:10:00 8.1 0.7 9.5 6.1 8 0.7 9.9 6.1 0.4 0 0.4 0.4 15 5 12 305 2 0 2 0 -19.7 0 -19.5 -20.1 02/02/2005 19:20:00 8.4 0.8 9.9 6.5 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 19 5 15 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 19:30:00 8.4 0.7 10.7 6.5 8.3 0.7 10.3 6.1 0.4 0 0.4 0.4 14 4 10 305 2 0 2 0 -19.6 0 -19.5 -19.7 02/02/2005 19:40:00 8.5 1 11.5 6.1 8.4 1 11.1 6.5 0.4 0 0.4 0.4 17 5 15 305 2 0 2 0 -19.6 0 -19.5 -19.7 02/02/2005 19:50:00 10 0.7 11.5 7.6 9.9 0.8 11.5 7.2 0.4 0 0.4 0.4 15 3 18 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 20:00:00 9.9 0.7 11.5 7.6 9.8 0.8 11.5 7.6 0.4 0 0.4 0.4 13 3 14 305 2 0 2 0 -19.8 0 -19.5 -20.1 02/02/2005 20:10:00 9.7 0.7 11.8 7.2 9.5 0.9 11.5 7.2 0.4 0 0.4 0.4 13 5 13 305 2 0 2 0 -20 0 -19.7 -20.1 02/02/2005 20:20:00 10.6 0.7 11.8 8 10.6 0.8 11.8 8 0.4 0 0.4 0.4 13 3 13 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/02/2005 20:30:00 10 0.7 11.5 7.6 10 0.8 11.8 8 0.4 0 0.4 0.4 13 3 15 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/02/2005 20:40:00 9.3 0.7 11.1 7.6 9.2 0.8 11.1 6.8 0.4 0 0.4 0.4 14 3 13 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/02/2005 20:50:00 8.6 0.8 10.7 6.5 8.5 0.9 10.7 6.5 0.4 0 0.4 0.4 12 4 16 305 2 0 2 0 -19.9 0 -19.5 -20.1 02/02/2005 21:00:00 8.8 0.5 10.3 7.2 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 10 3 15 305 2 0 2 0 -19.9 0 -19.5 -20.1 02/02/2005 21:10:00 8.3 0.8 9.9 6.5 8.3 0.8 10.3 6.1 0.4 0 0.4 0.4 10 4 12 305 2 0 2 0 -19.7 0 -19.5 -20.1 02/02/2005 21:20:00 9.1 0.7 10.3 7.2 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 8 3 17 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 21:30:00 8.4 0.9 10.3 6.5 8.4 0.9 10.7 6.5 0.4 0 0.4 0.4 10 5 17 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 21:40:00 9 0.8 10.7 6.5 8.9 0.8 10.7 6.1 0.4 0 0.4 0.4 7 4 10 305 2 0 2 0 -19.9 0 -19.5 -20.1 02/02/2005 21:50:00 8.9 0.8 10.7 6.5 8.8 0.9 11.1 6.5 0.4 0 0.4 0.4 11 5 7 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/02/2005 22:00:00 9 0.8 11.1 6.8 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 10 5 14 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/02/2005 22:10:00 8.1 1 9.9 5.7 8 1 9.9 5.3 0.4 0 0.4 0.4 9 5 7 305 2 0 2 0 -20 0 -19.7 -20.1 02/02/2005 22:20:00 8.8 0.8 10.3 6.8 8.8 0.9 11.1 6.8 0.4 0 0.4 0.4 9 4 11 305 2 0 2 0 -19.7 0.1 -19.5 -19.9 02/02/2005 22:30:00 8.4 1 10.7 6.1 8.5 1 10.3 6.1 0.4 0 0.4 0.4 3 5 6 305 2 0 2 0 -19.6 0 -19.5 -19.7 02/02/2005 22:40:00 8.2 0.8 10.3 6.1 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 5 5 8 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 22:50:00 9.1 0.8 10.7 6.8 9 0.8 11.1 6.8 0.4 0 0.4 0.4 6 4 8 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 23:00:00 9.2 0.7 10.7 7.2 9.2 0.7 10.7 7.2 0.4 0 0.4 0.4 8 5 14 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 23:10:00 8.8 0.7 10.3 6.8 8.8 0.8 10.3 6.8 0.4 0 0.4 0.4 7 4 3 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 23:20:00 9 0.7 10.7 7.2 8.9 0.7 10.7 6.8 0.4 0 0.4 0.4 8 4 4 305 2 0 2 0 -19.6 0 -19.5 -19.7 02/02/2005 23:30:00 9.8 0.7 11.8 7.6 9.7 0.8 11.8 7.6 0.4 0 0.4 0.4 8 3 7 305 2 0 2 0 -19.6 0 -19.5 -19.7 02/02/2005 23:40:00 9 0.8 10.7 6.8 9 0.8 11.1 6.8 0.4 0 0.4 0.4 11 5 17 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/02/2005 23:50:00 9.1 1 11.5 6.8 9 1.1 11.8 6.5 0.4 0 0.4 0.4 9 5 17 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/03/2005 00:00:00 8.8 0.8 10.7 6.8 8.9 0.8 10.3 6.5 0.4 0 0.4 0.4 9 4 7 305 2 0 2 0 -19.8 0 -19.3 -20.1 02/03/2005 00:10:00 8.6 0.8 10.3 6.5 8.5 0.8 10.7 6.5 0.4 0 0.4 0.4 10 4 10 305 2 0 2 0 -19.9 0 -19.5 -20.1 02/03/2005 00:20:00 8.5 0.8 10.3 6.5 8.5 0.8 10.3 6.1 0.4 0 0.4 0.4 8 5 6 305 2 0 2 0 -20 0 -19.7 -20.1 02/03/2005 00:30:00 8.3 0.8 9.9 5.7 8.3 0.8 9.9 6.1 0.4 0 0.4 0.4 3 5 4 305 2 0 2 0 -19.9 0 -19.9 -20.1 02/03/2005 00:40:00 8.3 0.8 9.9 6.1 8.3 0.9 10.3 5.7 0.4 0 0.4 0.4 1 4 359 305 2 0 2 0 -20 0 -19.7 -20.1 02/03/2005 00:50:00 8.6 0.8 9.9 6.5 8.5 0.8 10.3 5.7 0.4 0 0.4 0.4 4 4 3 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/03/2005 01:00:00 8.5 1 10.7 6.1 8.3 1 10.7 6.1 0.4 0 0.4 0.4 13 5 17 305 3 0 2 0 -19.7 0 -19.5 -19.9 02/03/2005 01:10:00 8.6 0.7 9.9 6.5 8.6 0.7 10.3 6.5 0.4 0 0.4 0.4 17 5 16 305 3 0 2 0 -19.6 0 -19.3 -19.7 02/03/2005 01:20:00 9.7 0.8 11.5 6.8 9.6 0.9 11.5 6.8 0.4 0 0.4 0.4 21 5 15 305 3 0 3 0 -19.5 0 -19.2 -19.5 02/03/2005 01:30:00 9.5 0.8 11.5 7.2 9.4 0.9 11.5 7.2 0.4 0 0.4 0.4 19 6 22 305 3 0 3 0 -19.5 0 -19.3 -19.5 02/03/2005 01:40:00 9.6 0.8 11.5 7.2 9.5 0.9 11.8 6.8 0.4 0 0.4 0.4 15 5 19 305 3 0 3 0 -19.5 0 -19 -19.5 02/03/2005 01:50:00 9.4 0.8 11.8 6.8 9.4 0.8 12.2 6.8 0.4 0 0.4 0.4 11 5 11 305 3 0 2 0 -19.6 0 -19.2 -19.5 02/03/2005 02:00:00 9.2 1 11.1 6.1 9.1 1.1 11.5 6.1 0.4 0 0.4 0.4 11 4 12 305 3 0 3 0 -19.7 0 -19.3 -19.7 02/03/2005 02:10:00 9.3 0.8 11.5 6.8 9.3 0.9 11.5 7.2 0.4 0 0.4 0.4 10 4 5 305 2 0 2 0 -19.7 0 -19.5 -19.7 02/03/2005 02:20:00 8.8 0.9 11.1 6.5 8.9 0.8 11.1 6.8 0.4 0 0.4 0.4 8 5 15 305 2 0 2 0 -19.6 0 -19.5 -19.7 02/03/2005 02:30:00 8.9 0.8 10.7 6.5 8.9 0.8 11.1 6.5 0.4 0 0.4 0.4 5 4 7 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/03/2005 02:40:00 8 0.8 9.9 6.1 8 0.9 10.3 5.7 0.4 0 0.4 0.4 4 4 1 305 2 0 2 0 -19.6 0 -19.5 -19.7 02/03/2005 02:50:00 7.7 0.7 9.5 5.7 7.6 0.7 9.1 5.3 0.4 0 0.4 0.4 6 4 6 305 2 0 2 0 -19.6 0 -19.3 -19.5 02/03/2005 03:00:00 6.9 0.5 8 5.3 6.8 0.6 8.4 4.9 0.4 0 0.4 0.4 3 5 6 305 2 0 2 0 -19.6 0 -19.3 -19.5 02/03/2005 03:10:00 7 0.7 8.8 5.3 7 0.7 8.8 4.9 0.4 0 0.4 0.4 0 4 358 305 2 0 2 0 -19.6 0 -19.2 -19.5 02/03/2005 03:20:00 7.5 0.7 8.8 5.3 7.4 0.8 9.1 5.3 0.4 0 0.4 0.4 0 4 3 305 2 0 2 0 -19.6 0 -19.2 -19.7 02/03/2005 03:30:00 7.9 0.6 9.5 6.5 7.9 0.6 9.1 6.5 0.4 0 0.4 0.4 3 4 2 305 2 0 2 0 -19.4 0 -19 -19.5 02/03/2005 03:40:00 8.5 0.7 10.3 6.8 8.4 0.7 10.3 6.8 0.4 0 0.4 0.4 8 4 4 305 2 0 2 0 -19.2 0 -19 -19.5 02/03/2005 03:50:00 8.9 0.9 10.7 6.1 8.7 1 10.7 5.7 0.4 0 0.4 0.4 10 4 9 305 2 0 2 0 -19.3 0.1 -19 -19.5 02/03/2005 04:00:00 8.5 0.8 9.9 6.5 8.4 0.7 10.3 6.5 0.4 0 0.4 0.4 10 4 15 305 2 0 2 0 -19.3 0 -19 -19.5 02/03/2005 04:10:00 8.6 0.8 10.3 6.5 8.5 0.8 10.3 6.5 0.4 0 0.4 0.4 11 5 16 305 3 0 3 0 -19.2 0 -19 -19.3 02/03/2005 04:20:00 8.8 0.8 10.3 6.8 8.7 0.8 10.3 6.5 0.4 0 0.4 0.4 12 3 16 305 3 0 2 0 -19.1 0 -18.8 -19.2 02/03/2005 04:30:00 8.5 0.8 10.3 6.5 8.5 0.8 10.3 6.5 0.4 0 0.4 0.4 9 4 13 305 3 0 3 0 -19 0 -18.8 -19.2 02/03/2005 04:40:00 8.5 0.9 10.3 6.1 8.4 1 10.3 6.1 0.4 0 0.4 0.4 8 4 13 305 3 0 3 0 -19.1 0 -18.8 -19.2 02/03/2005 04:50:00 8 0.6 9.5 6.1 8 0.7 9.9 6.5 0.4 0 0.4 0.4 8 4 7 305 3 0 3 0 -19.1 0 -18.8 -19.2 02/03/2005 05:00:00 8.3 0.9 9.9 6.1 8.3 1 10.3 5.7 0.4 0 0.4 0.4 8 4 4 305 3 0 3 0 -19.1 0 -19 -19.3 02/03/2005 05:10:00 8.8 0.7 10.7 6.5 8.7 0.8 10.3 6.5 0.4 0 0.4 0.4 9 4 4 305 3 0 3 0 -19.2 0 -19 -19.3 02/03/2005 05:20:00 8.4 1.1 11.1 5.7 8.3 1 10.7 5.7 0.4 0 0.4 0.4 10 5 11 305 3 0 3 0 -19.2 0 -19 -19.3 02/03/2005 05:30:00 8.9 1 10.7 5.7 8.8 1 10.7 6.5 0.4 0 0.4 0.4 10 5 7 305 3 0 3 0 -19.2 0 -19 -19.5 02/03/2005 05:40:00 9.2 0.8 11.1 7.2 9.1 0.8 11.1 7.2 0.4 0 0.4 0.4 9 4 9 305 3 0 2 0 -19.4 0.1 -19.2 -19.5 02/03/2005 05:50:00 8.4 0.8 10.3 6.1 8.4 0.8 9.9 6.5 0.4 0 0.4 0.4 10 5 21 305 3 0 3 0 -19.7 0 -19.5 -19.9 02/03/2005 06:00:00 8.6 1 11.1 6.1 8.6 1 11.5 6.1 0.4 0 0.4 0.4 14 5 18 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/03/2005 06:10:00 8.3 1 10.7 6.5 8.2 1 10.7 5.7 0.4 0 0.4 0.4 12 5 16 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/03/2005 06:20:00 8.4 1 10.7 6.1 8.5 1 10.3 6.1 0.4 0 0.4 0.4 11 4 9 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/03/2005 06:30:00 9.1 0.7 10.7 7.2 8.9 0.7 11.1 7.2 0.4 0 0.4 0.4 8 4 11 305 2 0 2 0 -19.8 0 -19.5 -19.9 02/03/2005 06:40:00 8.5 0.9 10.3 6.1 8.5 0.8 10.7 6.1 0.4 0 0.4 0.4 11 4 11 305 2 0 2 0 -19.7 0 -19.5 -19.7 02/03/2005 06:50:00 8.9 0.8 10.7 6.8 8.8 0.8 11.1 6.5 0.4 0 0.4 0.4 10 4 6 305 2 0 2 0 -19.6 0 -19.5 -19.7 02/03/2005 07:00:00 9.2 0.7 10.7 6.8 9.2 0.7 10.7 7.2 0.4 0 0.4 0.4 10 4 7 305 2 0 2 0 -19.6 0 -19.3 -19.7 02/03/2005 07:10:00 7.5 0.8 9.5 5.7 7.5 0.8 9.9 5.7 0.4 0 0.4 0.4 12 5 10 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/03/2005 07:20:00 8.6 0.9 10.3 6.5 8.4 0.9 10.3 6.5 0.4 0 0.4 0.4 10 4 11 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/03/2005 07:30:00 8.4 0.7 10.3 6.5 8.2 0.8 10.3 6.1 0.4 0 0.4 0.4 7 5 15 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/03/2005 07:40:00 8.2 0.6 9.5 6.1 8.1 0.7 9.5 6.1 0.4 0 0.4 0.4 6 4 6 305 2 0 2 0 -19.8 0.1 -19.5 -20.1 02/03/2005 07:50:00 7.7 0.6 8.8 5.7 7.7 0.7 9.1 5.7 0.4 0 0.4 0.4 5 4 10 305 2 0 2 0 -19.9 0 -19.5 -20.1 02/03/2005 08:00:00 7.4 0.6 9.1 6.1 7.4 0.6 9.1 6.1 0.4 0 0.4 0.4 7 4 7 305 2 0 2 0 -20 0 -19.7 -20.1 02/03/2005 08:10:00 8 0.6 9.1 5.7 8 0.7 9.1 6.1 0.4 0 0.4 0.4 6 4 10 305 2 0 2 0 -20 0 -19.9 -20.1 02/03/2005 08:20:00 8.1 0.7 9.5 6.1 8 0.7 9.9 6.1 0.4 0 0.4 0.4 7 4 5 305 2 0 2 0 -20.1 0 -19.7 -20.1 02/03/2005 08:30:00 7.8 0.6 9.1 5.7 7.6 0.7 9.1 5.7 0.4 0 0.4 0.4 7 4 2 305 2 0 2 0 -20.2 0 -19.9 -20.1 02/03/2005 08:40:00 7.4 0.8 9.1 5.7 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 9 5 14 305 2 0 2 0 -20 0 -19.7 -20.1 02/03/2005 08:50:00 7.9 0.7 9.1 5.7 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 8 4 3 305 2 0 2 0 -20 0 -19.9 -20.1 02/03/2005 09:00:00 7.7 0.6 9.1 6.1 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 8 5 351 305 2 0 2 0 -20 0 -19.7 -20.1 02/03/2005 09:10:00 6.9 0.6 8.4 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 8 5 11 305 2 0 2 0 -19.9 0 -19.5 -20.1 02/03/2005 09:20:00 7.3 0.8 9.1 4.9 7.2 0.8 9.1 5.3 0.4 0 0.4 0.4 13 5 12 305 3 0 2 0 -19.7 0 -19.5 -19.9 02/03/2005 09:30:00 7.2 0.8 8.8 5.3 7 0.9 9.5 4.6 0.4 0 0.4 0.4 15 6 355 305 3 0 2 0 -19.7 0 -19.5 -19.9 02/03/2005 09:40:00 7.4 0.8 9.1 5.3 7.3 0.9 9.1 5.3 0.4 0 0.4 0.4 12 4 11 305 3 0 2 0 -19.7 0 -19.5 -19.9 02/03/2005 09:50:00 7.2 0.7 8.8 5.7 7.1 0.7 8.8 5.3 0.4 0 0.4 0.4 14 4 16 305 2 0 2 0 -19.8 0 -19.5 -19.9 02/03/2005 10:00:00 7.2 0.6 8.8 5.7 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 17 5 18 305 2 0 2 0 -19.9 0 -19.5 -20.1 02/03/2005 10:10:00 7.2 0.7 8.8 5.7 7.1 0.7 8.8 5.3 0.4 0 0.4 0.4 20 5 21 305 2 0 2 0 -20 0 -19.7 -20.1 02/03/2005 10:20:00 7.2 0.7 9.1 5.3 7 0.7 8.8 4.9 0.4 0 0.4 0.4 25 5 24 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/03/2005 10:30:00 6.7 0.8 8.8 4.9 6.5 0.8 8.8 4.6 0.4 0 0.4 0.4 32 5 30 305 3 0 2 0 -19.8 0 -19.5 -20.1 02/03/2005 10:40:00 7.1 0.7 9.1 5.3 6.9 0.8 9.1 4.9 0.4 0 0.4 0.4 27 6 32 305 3 0 2 0 -19.6 0 -19.5 -19.7 02/03/2005 10:50:00 6.6 0.8 8.8 4.6 6.5 0.7 8.4 4.6 0.4 0 0.4 0.4 27 6 20 305 3 0 2 0 -19.5 0 -19.3 -19.5 02/03/2005 11:00:00 6.6 0.8 8.4 4.9 6.6 0.8 8.4 4.6 0.4 0 0.4 0.4 28 7 25 305 3 0 3 0 -19.4 0 -19.3 -19.5 02/03/2005 11:10:00 6.3 0.9 8.8 4.6 6.3 0.9 8.8 4.2 0.4 0 0.4 0.4 26 8 22 305 3 0 3 0 -19.4 0 -19.2 -19.5 02/03/2005 11:20:00 7.1 0.6 9.5 5.3 7 0.6 9.1 5.3 0.4 0 0.4 0.4 25 6 27 305 3 0 3 0 -19.3 0 -19.2 -19.5 02/03/2005 11:30:00 6.8 0.7 8.8 5.3 6.7 0.8 9.1 4.6 0.4 0 0.4 0.4 46 11 38 305 3 0 3 0 -19.4 0 -19.2 -19.5 02/03/2005 11:40:00 6.9 0.8 8.8 4.9 6.9 0.8 8.8 4.6 0.4 0 0.4 0.4 35 11 56 305 3 0 3 0 -19.4 0 -19 -19.5 02/03/2005 11:50:00 7.1 0.6 8.4 5.7 7.1 0.7 8.8 5.3 0.4 0 0.4 0.4 43 8 35 305 3 0 3 0 -19.5 0.1 -19 -19.5 02/03/2005 12:00:00 8 0.5 9.1 6.5 8 0.6 9.1 6.1 0.4 0 0.4 0.4 52 3 51 305 3 0 3 0 -19.7 0 -19.3 -19.9 02/03/2005 12:10:00 7.5 0.5 9.1 5.3 7.4 0.5 8.8 6.1 0.4 0 0.4 0.4 53 4 51 305 3 0 3 0 -19.7 0 -19.3 -19.9 02/03/2005 12:20:00 7.4 0.8 9.1 5.3 7.4 0.9 9.1 4.6 0.4 0 0.4 0.4 47 4 46 305 3 0 3 0 -19.6 0 -19.3 -19.7 02/03/2005 12:30:00 7.3 0.8 9.1 4.9 7.1 0.8 9.1 4.9 0.4 0 0.4 0.4 51 6 54 305 3 0 3 0 -19.6 0 -19.3 -19.7 02/03/2005 12:40:00 6.9 0.7 8.8 4.9 6.8 0.7 8.8 4.9 0.4 0 0.4 0.4 41 5 38 305 3 0 3 0 -19.6 0 -19.3 -19.7 02/03/2005 12:50:00 6.4 0.7 8 4.6 6.3 0.8 8.4 4.6 0.4 0 0.4 0.4 35 5 32 305 3 0 3 0 -19.6 0 -19.2 -19.7 02/03/2005 13:00:00 7.1 0.8 8.8 5.3 7 0.8 8.8 4.9 0.4 0 0.4 0.4 35 6 31 305 3 0 3 0 -19.6 0 -19.2 -19.9 02/03/2005 13:10:00 6.6 1 9.1 4.6 6.5 1 9.1 4.2 0.4 0 0.4 0.4 35 7 31 305 3 0 3 0 -19.7 0 -19.3 -19.9 02/03/2005 13:20:00 7 0.7 8.8 4.9 7 0.8 8.8 4.6 0.4 0 0.4 0.4 44 6 53 305 3 0 3 0 -19.7 0 -19.3 -19.9 02/03/2005 13:30:00 7.4 0.6 8.8 6.1 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 48 4 52 305 3 0 3 0 -19.7 0 -19.5 -19.9 02/03/2005 13:40:00 7.2 0.7 8.4 5.3 7.2 0.7 8.4 5.3 0.4 0 0.4 0.4 46 5 46 305 3 0 3 0 -19.7 0.1 -19.3 -19.9 02/03/2005 13:50:00 7.3 0.7 8.8 5.3 7.2 0.8 9.1 5.3 0.4 0 0.4 0.4 49 5 49 305 3 0 3 0 -19.8 0.1 -19.5 -20.1 02/03/2005 14:00:00 7.8 0.5 8.8 6.1 7.7 0.6 8.8 5.3 0.4 0 0.4 0.4 47 4 48 305 3 0 3 0 -20 0 -19.7 -20.1 02/03/2005 14:10:00 7.6 0.6 8.8 5.7 7.6 0.7 9.1 5.7 0.4 0 0.4 0.4 44 5 56 305 3 0 2 0 -20.2 0 -20.1 -20.2 02/03/2005 14:20:00 6.3 0.9 8.4 4.2 6.3 0.9 8.4 4.2 0.4 0 0.4 0.4 44 8 34 305 3 0 2 0 -19.9 0.2 -19.5 -20.1 02/03/2005 14:30:00 6.2 1.2 8.8 4.2 6.1 1.2 9.1 3.8 0.4 0 0.4 0.4 45 7 41 305 3 0 3 0 -19.8 0.1 -19.5 -20.1 02/03/2005 14:40:00 6.9 0.8 8.8 4.9 6.8 0.8 8.8 4.6 0.4 0 0.4 0.4 46 6 43 305 3 0 3 0 -20.2 0 -20.1 -20.2 02/03/2005 14:50:00 7.3 0.7 8.8 5.3 7.2 0.8 9.1 4.9 0.4 0 0.4 0.4 51 6 46 305 3 0 2 0 -20.1 0 -19.9 -20.1 02/03/2005 15:00:00 6.2 0.6 7.6 4.9 6 0.6 7.6 4.6 0.4 0 0.4 0.4 50 6 50 305 3 0 2 0 -19.8 0.1 -19.5 -20.1 02/03/2005 15:10:00 6.3 0.7 8 4.2 6.2 0.8 7.6 4.2 0.4 0 0.4 0.4 52 5 58 305 3 0 3 0 -19.8 0 -19.5 -20.1 02/03/2005 15:20:00 6.3 0.6 7.6 4.6 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 53 4 56 305 2 0 2 0 -19.8 0 -19.5 -20.1 02/03/2005 15:30:00 5 0.7 6.5 3 4.9 0.8 6.5 2.6 0.4 0 0.4 0.4 51 5 48 305 2 0 2 0 -19.7 0 -19.5 -19.9 02/03/2005 15:40:00 5.7 0.6 6.8 4.2 5.6 0.6 6.8 3.8 0.4 0 0.4 0.4 44 5 44 305 3 0 2 0 -19.6 0 -19.5 -19.7 02/03/2005 15:50:00 4.7 0.5 6.1 3.4 4.6 0.5 6.5 3.4 0.4 0 0.4 0.4 30 9 30 305 3 0 2 0 -19.5 0 -19.2 -19.5 02/03/2005 16:00:00 5.8 0.5 7.2 3.8 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 37 8 35 305 2 0 2 0 -19.5 0.1 -19.2 -19.5 02/03/2005 16:10:00 6.1 0.5 7.6 4.9 6.1 0.6 7.6 4.9 0.4 0 0.4 0.4 44 5 50 305 2 0 2 0 -19.6 0 -19.3 -19.7 02/03/2005 16:20:00 6.4 0.6 7.6 4.9 6.4 0.6 7.6 4.6 0.4 0 0.4 0.4 36 8 43 305 2 0 2 0 -19.6 0 -19.3 -19.7 02/03/2005 16:30:00 6.9 0.6 8.4 4.9 6.8 0.7 8.8 4.9 0.4 0 0.4 0.4 33 9 42 305 2 0 2 0 -19.6 0 -19.2 -19.7 02/03/2005 16:40:00 6.5 0.6 8 4.9 6.5 0.7 8 4.6 0.4 0 0.4 0.4 38 6 32 305 2 0 2 0 -19.6 0 -19.2 -19.5 02/03/2005 16:50:00 6.4 0.7 8 4.6 6.3 0.7 8 4.6 0.4 0 0.4 0.4 26 7 21 305 2 0 2 0 -19.6 0 -19.2 -19.7 02/03/2005 17:00:00 6.7 0.6 8.4 5.3 6.6 0.6 8.4 5.3 0.4 0 0.4 0.4 22 5 25 305 2 0 2 0 -19.7 0 -19.3 -19.7 02/03/2005 17:10:00 6.9 0.7 8.4 4.9 6.9 0.7 8.8 4.9 0.4 0 0.4 0.4 39 9 24 305 2 0 2 0 -19.7 0 -19.3 -19.9 02/03/2005 17:20:00 6.5 0.7 8 4.2 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 28 6 24 305 2 0 2 0 -19.7 0.1 -19.5 -19.9 02/03/2005 17:30:00 6.3 0.8 8.4 4.2 6.2 0.9 8.4 4.2 0.4 0 0.4 0.4 32 7 32 305 2 0 2 0 -19.7 0 -19.3 -19.9 02/03/2005 17:40:00 6.9 0.6 8.4 5.3 6.8 0.6 8.4 4.9 0.4 0 0.4 0.4 35 6 23 305 2 0 2 0 -19.7 0 -19.3 -19.9 02/03/2005 17:50:00 6.9 0.8 9.1 4.9 6.9 0.8 8.8 4.9 0.4 0 0.4 0.4 42 6 39 305 2 0 2 0 -19.8 0.1 -19.5 -20.1 02/03/2005 18:00:00 7.2 0.8 8.8 4.6 7.1 0.9 8.8 4.6 0.4 0 0.4 0.4 45 7 37 305 2 0 2 0 -20.2 0 -19.9 -20.4 02/03/2005 18:10:00 6.6 0.7 8.4 4.6 6.4 0.7 8.4 4.9 0.4 0 0.4 0.4 51 5 51 305 2 0 2 0 -20.4 0.1 -20.1 -20.8 02/03/2005 18:20:00 6 0.7 7.2 3.8 5.7 0.7 7.2 3.8 0.4 0 0.4 0.4 53 5 46 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/03/2005 18:30:00 5.6 0.5 6.8 4.2 5.4 0.6 7.2 4.2 0.4 0 0.4 0.4 55 4 47 305 2 0 2 0 -20.7 0 -20.4 -21 02/03/2005 18:40:00 5.8 0.6 7.2 4.2 5.6 0.6 7.2 3.8 0.4 0 0.4 0.4 53 5 51 305 2 0 2 0 -20.7 0 -20.8 -21 02/03/2005 18:50:00 5.8 0.6 7.6 4.6 5.4 0.7 6.8 4.2 0.4 0 0.4 0.4 54 5 60 305 2 0 2 0 -20.8 0.1 -20.8 -21.1 02/03/2005 19:00:00 6.2 0.6 7.6 4.6 5.9 0.6 7.6 4.6 0.4 0 0.4 0.4 56 4 45 305 2 0 2 0 -21 0 -20.8 -21.1 02/03/2005 19:10:00 6.3 0.6 8 4.9 6.2 0.6 8 4.6 0.4 0 0.4 0.4 55 4 53 305 2 0 2 0 -21 0 -20.8 -21.1 02/03/2005 19:20:00 6.3 0.7 8 4.2 6.2 0.7 8 4.6 0.4 0 0.4 0.4 53 5 48 305 2 0 2 0 -21 0 -20.8 -21.1 02/03/2005 19:30:00 5.8 0.5 6.8 4.6 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 54 5 49 305 2 0 2 0 -21 0 -20.4 -21.3 02/03/2005 19:40:00 5.7 0.5 6.8 4.6 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 53 4 57 305 2 0 2 0 -21.1 0 -21 -21.3 02/03/2005 19:50:00 6 0.6 8 4.6 5.8 0.6 8 4.6 0.4 0 0.4 0.4 51 5 46 305 2 0 2 0 -21.1 0 -20.8 -21.3 02/03/2005 20:00:00 6.5 0.7 8.8 4.6 6.4 0.7 8.8 4.6 0.4 0 0.4 0.4 49 5 44 305 2 0 2 0 -21 0 -20.8 -21.3 02/03/2005 20:10:00 5.8 0.6 7.6 4.2 5.5 0.6 7.2 4.2 0.4 0 0.4 0.4 50 5 40 305 2 0 2 0 -21.1 0 -21 -21.3 02/03/2005 20:20:00 5.4 0.6 6.8 3.8 5.2 0.6 6.8 3.8 0.4 0 0.4 0.4 53 6 46 305 2 0 2 0 -21.2 0 -21 -21.3 02/03/2005 20:30:00 5.1 0.5 6.1 3.4 4.9 0.5 6.1 3.8 0.4 0 0.4 0.4 60 4 66 305 2 0 2 0 -21.3 0.1 -21.3 -21.7 02/03/2005 20:40:00 5 0.4 6.1 4.2 4.8 0.4 5.7 3.4 0.4 0 0.4 0.4 59 4 60 305 2 0 2 0 -21.4 0 -21.3 -21.7 02/03/2005 20:50:00 5.3 0.5 6.8 4.2 5.2 0.5 6.5 4.2 0.4 0 0.4 0.4 59 4 59 305 2 0 2 0 -21.5 0 -21.3 -21.7 02/03/2005 21:00:00 5.7 0.4 6.5 4.6 5.6 0.4 6.5 4.6 0.4 0 0.4 0.4 59 3 62 305 2 0 2 0 -21.4 0 -21.3 -21.5 02/03/2005 21:10:00 5.2 0.4 6.1 4.2 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 59 5 59 305 2 0 2 0 -21.4 0.1 -21.1 -21.7 02/03/2005 21:20:00 5.6 0.6 7.6 4.2 5.4 0.6 6.8 4.2 0.4 0 0.4 0.4 59 5 57 305 2 0 2 0 -21.4 0 -21.3 -21.7 02/03/2005 21:30:00 5.7 0.4 6.8 4.9 5.6 0.4 6.8 4.6 0.4 0 0.4 0.4 60 4 63 305 2 0 2 0 -21.3 0 -21.3 -21.7 02/03/2005 21:40:00 5.5 0.4 6.8 4.6 5.4 0.5 6.8 4.2 0.4 0 0.4 0.4 61 4 61 305 2 0 2 0 -21.4 0 -21.3 -21.5 02/03/2005 21:50:00 6 0.4 7.2 4.6 5.9 0.5 7.2 4.9 0.4 0 0.4 0.4 63 5 60 305 2 0 2 0 -21.3 0 -21.1 -21.5 02/03/2005 22:00:00 5.8 0.4 7.2 4.6 5.7 0.5 7.2 4.2 0.4 0 0.4 0.4 62 5 59 305 2 0 2 0 -21.4 0 -21.3 -21.5 02/03/2005 22:10:00 5.7 0.4 6.5 4.6 5.5 0.4 6.8 4.6 0.4 0 0.4 0.4 63 3 62 305 2 0 2 0 -21.5 0.1 -21.3 -21.8 02/03/2005 22:20:00 5.5 0.4 6.8 4.6 5.3 0.5 6.8 4.2 0.4 0 0.4 0.4 63 3 51 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/03/2005 22:30:00 5.8 0.3 6.8 5.3 5.6 0.3 6.5 4.9 0.4 0 0.4 0.4 64 3 60 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/03/2005 22:40:00 5.8 0.3 6.5 5.3 5.6 0.3 6.5 4.9 0.4 0 0.4 0.4 63 2 67 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/03/2005 22:50:00 5.8 0.4 6.8 4.9 5.7 0.4 7.2 4.6 0.4 0 0.4 0.4 61 3 62 305 2 0 2 0 -21.7 0 -21.3 -21.8 02/03/2005 23:00:00 5.9 0.4 6.8 4.9 5.7 0.4 6.8 4.6 0.4 0 0.4 0.4 61 4 65 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/03/2005 23:10:00 5.7 0.4 6.5 4.2 5.4 0.5 6.5 4.2 0.4 0 0.4 0.4 62 4 64 305 2 0 2 0 -21.8 0 -21.7 -21.8 02/03/2005 23:20:00 5.6 0.3 6.5 4.9 5.4 0.4 6.1 4.6 0.4 0 0.4 0.4 60 3 62 305 2 0 2 0 -21.8 0 -21.7 -21.8 02/03/2005 23:30:00 5.8 0.4 6.5 4.6 5.6 0.4 6.5 4.2 0.4 0 0.4 0.4 60 2 62 305 2 0 1 0 -21.8 0 -21.5 -22 02/03/2005 23:40:00 6.3 0.4 7.2 4.9 6.1 0.4 7.2 4.6 0.4 0 0.4 0.4 61 3 67 305 2 0 2 0 -21.8 0 -21.7 -21.8 02/03/2005 23:50:00 6.3 0.4 6.8 4.9 6.1 0.4 6.8 4.9 0.4 0 0.4 0.4 61 2 61 305 2 0 2 0 -21.8 0 -21.7 -21.8 02/04/2005 00:00:00 6.3 0.3 6.8 5.3 6.2 0.4 6.8 4.9 0.4 0 0.4 0.4 59 3 56 305 2 0 2 0 -21.7 0.1 -21.3 -21.8 02/04/2005 00:10:00 6.4 0.4 7.2 5.7 6.2 0.4 7.2 5.3 0.4 0 0.4 0.4 57 3 51 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/04/2005 00:20:00 6.4 0.5 7.2 4.6 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 56 4 60 305 2 0 2 0 -21.8 0 -21.7 -21.8 02/04/2005 00:30:00 6.5 0.7 8 4.9 6.4 0.7 8 4.9 0.4 0 0.4 0.4 54 4 48 305 2 0 2 0 -22 0 -21.8 -22.2 02/04/2005 00:40:00 6.3 0.4 7.6 5.3 6.2 0.5 7.6 4.9 0.4 0 0.4 0.4 55 3 55 305 2 0 2 0 -22.1 0 -21.8 -22.2 02/04/2005 00:50:00 5.3 0.5 6.5 4.2 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 59 5 60 305 2 0 2 0 -22.2 0 -22 -22.4 02/04/2005 01:00:00 5.5 0.6 7.2 3.8 5.2 0.7 7.2 3.8 0.4 0 0.4 0.4 58 5 54 305 2 0 2 0 -22.2 0 -21.8 -22.4 02/04/2005 01:10:00 5.9 0.7 7.6 4.2 5.8 0.8 7.6 4.2 0.4 0 0.4 0.4 56 5 59 305 2 0 2 0 -21.9 0 -21.8 -22 02/04/2005 01:20:00 6.3 0.4 7.2 5.3 6.1 0.4 7.2 4.9 0.4 0 0.4 0.4 57 2 59 305 2 0 2 0 -21.8 0 -21.8 -22 02/04/2005 01:30:00 6 0.6 7.6 4.6 5.8 0.6 7.2 4.2 0.4 0 0.4 0.4 55 4 57 305 2 0 2 0 -21.9 0.1 -21.8 -22 02/04/2005 01:40:00 5.9 0.6 7.2 4.2 5.8 0.6 7.6 4.2 0.4 0 0.4 0.4 52 5 50 305 2 0 2 0 -21.9 0 -21.8 -22 02/04/2005 01:50:00 5.8 0.5 6.8 4.2 5.7 0.5 6.8 4.2 0.4 0 0.4 0.4 49 5 47 305 2 0 2 0 -21.9 0.1 -21.5 -22.2 02/04/2005 02:00:00 5.2 0.6 6.8 3.4 5 0.6 6.8 3.8 0.4 0 0.4 0.4 43 5 48 305 2 0 2 0 -22 0 -21.8 -22.2 02/04/2005 02:10:00 4.6 0.6 6.1 3.4 4.5 0.6 5.7 3 0.4 0 0.4 0.4 47 3 46 305 2 0 2 0 -22 0 -21.8 -22.2 02/04/2005 02:20:00 4.4 0.3 4.9 3.4 4.2 0.3 4.9 3.4 0.4 0 0.4 0.4 49 3 50 305 2 0 2 0 -22.2 0.1 -21.8 -22.4 02/04/2005 02:30:00 4.2 0.6 6.1 3 4.1 0.6 6.5 3 0.4 0 0.4 0.4 54 5 57 305 2 0 2 0 -22.1 0.1 -21.5 -22.2 02/04/2005 02:40:00 5.2 0.7 6.8 3.4 5 0.8 6.8 3 0.4 0 0.4 0.4 54 5 50 305 2 0 2 0 -21.8 0 -21.3 -22 02/04/2005 02:50:00 4.7 0.6 6.1 3 4.5 0.5 6.1 3 0.4 0 0.4 0.4 54 7 60 305 2 0 2 0 -21.7 0.1 -21.3 -21.8 02/04/2005 03:00:00 3 0.8 4.9 1.1 2.9 0.8 4.6 1.1 0.4 0 0.4 0.4 50 7 37 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/04/2005 03:10:00 2.9 1 4.9 1.5 2.6 0.9 4.6 0.7 0.4 0 0.4 0.4 60 9 62 305 2 0 2 0 -21.6 0 -21.3 -21.8 02/04/2005 03:20:00 4.4 0.5 5.7 3.4 4.1 0.5 5.7 3 0.4 0 0.4 0.4 66 7 72 305 2 0 2 0 -21.4 0.1 -21.3 -21.7 02/04/2005 03:30:00 4.8 0.4 5.7 3.8 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 68 6 62 305 2 0 2 0 -21.3 0 -21.3 -21.3 02/04/2005 03:40:00 4.4 0.5 5.7 3 4.3 0.6 5.7 2.6 0.4 0 0.4 0.4 68 6 53 305 2 0 2 0 -21.2 0 -21 -21.3 02/04/2005 03:50:00 4.2 0.4 4.9 3 4 0.4 4.9 3 0.4 0 0.4 0.4 65 4 58 305 2 0 2 0 -21.2 0 -21 -21.3 02/04/2005 04:00:00 4.6 0.7 6.5 3.4 4.4 0.7 6.5 3 0.4 0 0.4 0.4 68 7 67 305 2 0 2 0 -21.1 0 -20.8 -21.3 02/04/2005 04:10:00 4.9 0.7 6.5 3.4 4.7 0.7 6.5 3.4 0.4 0 0.4 0.4 68 8 59 305 2 0 2 0 -21 0 -20.8 -21.3 02/04/2005 04:20:00 5.5 0.5 6.8 4.2 5.2 0.5 6.5 3.8 0.4 0 0.4 0.4 66 6 70 305 2 0 2 0 -20.8 0 -20.8 -21 02/04/2005 04:30:00 5.6 0.5 7.6 4.6 5.5 0.6 6.8 4.2 0.4 0 0.4 0.4 54 6 41 305 2 0 2 0 -21 0 -20.8 -21.1 02/04/2005 04:40:00 4.9 0.5 6.5 3.4 4.7 0.5 6.1 3.8 0.4 0 0.4 0.4 69 8 62 305 2 0 2 0 -21.1 0 -20.8 -21.3 02/04/2005 04:50:00 5.2 0.5 6.5 4.2 5.1 0.6 6.5 3.8 0.4 0 0.4 0.4 56 10 56 305 2 0 2 0 -21.1 0.1 -21 -21.3 02/04/2005 05:00:00 5.7 0.6 7.2 4.2 5.6 0.6 7.2 4.2 0.4 0 0.4 0.4 63 8 68 305 2 0 2 0 -21.1 0 -20.8 -21.3 02/04/2005 05:10:00 5.5 0.7 7.2 3.8 5.3 0.7 7.2 3.8 0.4 0 0.4 0.4 63 8 62 305 2 0 2 0 -21 0 -20.8 -21.1 02/04/2005 05:20:00 4.1 0.7 5.7 2.3 3.9 0.7 5.7 2.3 0.4 0 0.4 0.4 61 5 59 305 2 0 2 0 -21 0 -20.8 -21.1 02/04/2005 05:30:00 4.6 0.5 6.1 3.4 4.6 0.5 6.1 3.4 0.4 0 0.4 0.4 56 7 60 305 2 0 2 0 -20.9 0 -20.8 -21.1 02/04/2005 05:40:00 4.3 0.6 5.7 2.6 4.1 0.5 5.7 2.6 0.4 0 0.4 0.4 61 8 71 305 2 0 2 0 -20.9 0 -20.8 -21 02/04/2005 05:50:00 3.4 0.6 4.9 2.3 3.3 0.6 4.9 1.9 0.4 0 0.4 0.4 53 11 71 305 2 0 2 0 -20.8 0 -20.8 -21 02/04/2005 06:00:00 4.1 0.6 5.3 2.6 4.1 0.6 5.3 2.6 0.4 0 0.4 0.4 51 8 57 305 2 0 2 0 -20.8 0 -20.6 -21 02/04/2005 06:10:00 3.8 0.9 6.5 2.3 3.9 0.9 6.1 2.3 0.4 0 0.4 0.4 55 6 54 305 2 0 2 0 -20.7 0 -20.6 -20.8 02/04/2005 06:20:00 3.8 0.5 5.3 2.6 3.7 0.6 5.3 2.6 0.4 0 0.4 0.4 55 11 44 305 2 0 2 0 -20.7 0 -20.4 -20.8 02/04/2005 06:30:00 4.4 0.4 5.7 3.4 4.4 0.4 5.3 3.4 0.4 0 0.4 0.4 46 5 38 305 2 0 2 0 -20.7 0 -20.4 -20.8 02/04/2005 06:40:00 4.6 0.8 7.2 3 4.4 0.8 7.2 3 0.4 0 0.4 0.4 63 8 63 305 2 0 2 0 -20.7 0 -20.4 -21 02/04/2005 06:50:00 5.2 0.5 6.5 4.2 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 61 7 62 305 2 0 2 0 -20.7 0 -20.4 -20.8 02/04/2005 07:00:00 5 0.4 6.1 3.8 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 69 4 67 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/04/2005 07:10:00 4.3 0.5 5.3 3 4.1 0.5 4.9 2.6 0.4 0 0.4 0.4 74 5 75 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/04/2005 07:20:00 4.1 0.5 5.7 2.6 3.8 0.5 5.3 2.6 0.4 0 0.4 0.4 77 6 85 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/04/2005 07:30:00 4.1 0.4 5.3 3.4 3.9 0.4 4.9 3 0.4 0 0.4 0.4 77 4 82 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/04/2005 07:40:00 3.9 0.5 4.9 2.6 3.7 0.5 4.9 2.6 0.4 0 0.4 0.4 66 8 75 305 2 0 2 0 -20.6 0 -20.2 -20.8 02/04/2005 07:50:00 3.1 0.5 4.6 1.9 2.9 0.5 4.2 1.5 0.4 0 0.4 0.4 58 8 62 305 2 0 2 0 -20.5 0 -20.2 -20.8 02/04/2005 08:00:00 2.5 0.5 3.8 1.5 2.4 0.4 3 1.5 0.4 0 0.4 0.4 49 7 58 305 2 0 2 0 -20.5 0 -20.2 -20.6 02/04/2005 08:10:00 2.3 0.4 3 1.5 2.3 0.4 3 1.5 0.4 0 0.4 0.4 48 6 51 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/04/2005 08:20:00 2.4 0.4 3.4 1.5 2.4 0.3 3.4 1.5 0.4 0 0.4 0.4 46 6 48 305 2 0 2 0 -20.3 0 -20.1 -20.4 02/04/2005 08:30:00 3.3 0.4 4.2 2.3 3.3 0.4 4.6 2.3 0.4 0 0.4 0.4 45 5 44 305 2 0 2 0 -20.2 0 -20.1 -20.2 02/04/2005 08:40:00 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 0.4 0 0.4 0.4 42 6 54 305 2 0 2 0 -20.2 0 -20.1 -20.2 02/04/2005 08:50:00 3.7 0.4 4.6 2.3 3.7 0.4 4.9 2.3 0.4 0 0.4 0.4 50 6 61 305 2 0 2 0 -20.2 0 -19.9 -20.2 02/04/2005 09:00:00 4.3 0.5 5.7 3 4.3 0.5 5.7 3.4 0.4 0 0.4 0.4 56 5 62 305 2 0 2 0 -20.2 0 -19.9 -20.1 02/04/2005 09:10:00 4.5 0.5 5.7 3.4 4.4 0.4 5.3 3.4 0.4 0 0.4 0.4 63 8 69 305 2 0 2 0 -20.1 0.1 -19.7 -20.1 02/04/2005 09:20:00 4.3 0.8 6.5 3 4.1 0.8 6.1 2.6 0.4 0 0.4 0.4 70 7 69 305 2 0 2 0 -20.1 0 -19.9 -20.1 02/04/2005 09:30:00 4.3 0.5 5.3 3.4 4.2 0.5 5.3 3.4 0.4 0 0.4 0.4 68 7 67 305 2 0 2 0 -20.1 0 -19.9 -20.1 02/04/2005 09:40:00 4.3 0.7 6.5 3 4.1 0.6 5.7 2.6 0.4 0 0.4 0.4 70 10 69 305 2 0 2 0 -20.1 0 -19.9 -20.1 02/04/2005 09:50:00 3.5 0.4 4.6 2.6 3.5 0.4 4.6 2.6 0.4 0 0.4 0.4 59 8 58 305 2 0 2 0 -20.1 0.1 -19.7 -20.1 02/04/2005 10:00:00 4.6 0.7 6.8 3 4.6 0.7 6.8 3 0.4 0 0.4 0.4 51 9 56 305 2 0 2 0 -20 0 -19.5 -20.1 02/04/2005 10:10:00 4.9 0.6 6.1 3 4.8 0.6 6.1 3 0.4 0 0.4 0.4 48 7 54 305 2 0 2 0 -19.9 0 -19.5 -20.1 02/04/2005 10:20:00 5.1 0.7 6.5 3.4 5.1 0.8 6.5 3 0.4 0 0.4 0.4 49 5 41 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/04/2005 10:30:00 4.9 0.5 6.1 3.4 4.9 0.5 6.1 3.4 0.4 0 0.4 0.4 42 5 40 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/04/2005 10:40:00 5.5 0.6 6.8 3.8 5.5 0.7 6.8 3.8 0.4 0 0.4 0.4 39 6 46 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/04/2005 10:50:00 5.7 0.6 6.8 4.2 5.8 0.5 7.6 4.6 0.4 0 0.4 0.4 41 6 35 305 2 0 2 0 -19.9 0 -19.7 -20.1 02/04/2005 11:00:00 5.7 0.7 7.2 4.2 5.7 0.8 7.2 3.4 0.4 0 0.4 0.4 41 5 39 305 2 0 2 0 -19.9 0 -19.5 -20.1 02/04/2005 11:10:00 5.9 0.7 7.6 4.2 5.8 0.7 7.6 4.2 0.4 0 0.4 0.4 43 5 44 305 2 0 2 0 -20 0 -19.5 -20.1 02/04/2005 11:20:00 7 0.7 8 4.6 6.9 0.7 8.4 4.6 0.4 0 0.4 0.4 40 4 41 305 3 0 2 0 -19.9 0 -19.5 -20.1 02/04/2005 11:30:00 7.3 0.6 8.4 5.7 7.3 0.7 8.4 5.3 0.4 0 0.4 0.4 45 4 48 305 3 0 3 0 -19.9 0 -19.5 -20.1 02/04/2005 11:40:00 7 0.6 8.4 5.3 7 0.6 8.8 4.9 0.4 0 0.4 0.4 45 6 44 305 3 0 2 0 -19.9 0 -19.5 -20.1 02/04/2005 11:50:00 6.7 0.7 7.6 4.9 6.6 0.7 8 4.9 0.4 0 0.4 0.4 41 5 32 305 3 0 2 0 -19.9 0 -19.5 -20.1 02/04/2005 12:00:00 6.4 0.6 8 4.9 6.4 0.6 8 4.9 0.4 0 0.4 0.4 43 5 43 305 3 0 2 0 -20 0 -19.5 -20.1 02/04/2005 12:10:00 6.4 0.7 8 4.9 6.4 0.7 8.4 4.9 0.4 0 0.4 0.4 46 5 42 305 3 0 2 0 -20 0 -19.5 -20.1 02/04/2005 12:20:00 7.1 0.5 8 5.7 7.1 0.5 8.4 5.3 0.4 0 0.4 0.4 44 4 44 305 3 0 2 0 -19.9 0 -19.5 -20.1 02/04/2005 12:30:00 6.8 0.6 8.8 5.7 6.8 0.7 8.8 5.3 0.4 0 0.4 0.4 45 5 43 305 3 0 2 0 -19.9 0 -19.5 -20.1 02/04/2005 12:40:00 7.3 0.5 8.4 5.7 7.3 0.6 8.4 5.7 0.4 0 0.4 0.4 42 3 42 305 3 0 2 0 -20 0 -19.5 -20.1 02/04/2005 12:50:00 6 0.7 7.6 4.2 6 0.8 7.6 4.2 0.4 0 0.4 0.4 46 7 40 305 3 0 2 0 -19.9 0 -19.5 -20.1 02/04/2005 13:00:00 5.7 0.8 7.2 3.8 5.7 0.9 7.6 4.2 0.4 0 0.4 0.4 48 6 47 305 3 0 2 0 -19.8 0 -19.5 -20.1 02/04/2005 13:10:00 5.9 0.6 7.2 4.2 6 0.6 7.2 3.8 0.4 0 0.4 0.4 45 5 46 305 3 0 3 0 -19.8 0 -19.5 -19.9 02/04/2005 13:20:00 5.8 0.5 6.8 4.6 5.7 0.6 7.2 4.6 0.4 0 0.4 0.4 46 6 41 305 3 0 2 0 -19.8 0 -19.5 -19.9 02/04/2005 13:30:00 6 0.6 7.6 4.6 6 0.6 7.6 4.2 0.4 0 0.4 0.4 43 6 41 305 3 0 3 0 -19.8 0 -19.5 -20.1 02/04/2005 13:40:00 5.6 0.7 6.8 3.8 5.6 0.7 7.2 4.2 0.4 0 0.4 0.4 50 6 54 305 3 0 3 0 -19.7 0 -19.3 -19.9 02/04/2005 13:50:00 5.6 0.8 7.2 3.8 5.6 0.8 7.2 3.8 0.4 0 0.4 0.4 49 6 45 305 3 0 3 0 -19.6 0.1 -19 -19.9 02/04/2005 14:00:00 5.4 0.4 6.8 4.2 5.4 0.5 6.5 4.2 0.4 0 0.4 0.4 53 5 52 305 3 0 3 0 -19.2 0.1 -19 -19.5 02/04/2005 14:10:00 6.3 0.5 7.2 4.9 6.2 0.5 7.2 4.2 0.4 0 0.4 0.4 56 4 58 305 3 0 3 0 -19.2 0.1 -19 -19.5 02/04/2005 14:20:00 6.3 0.5 7.6 5.3 6.2 0.6 8 4.9 0.4 0 0.4 0.4 57 4 57 305 3 0 3 0 -19.4 0.1 -19 -19.5 02/04/2005 14:30:00 6.9 0.6 8 5.3 6.8 0.6 8.4 5.3 0.4 0 0.4 0.4 55 5 52 305 3 0 3 0 -19.6 0 -19.3 -19.7 02/04/2005 14:40:00 7.3 0.6 8.4 5.3 7.2 0.7 8.8 5.3 0.4 0 0.4 0.4 53 4 54 305 3 0 2 0 -19.7 0 -19.5 -19.9 02/04/2005 14:50:00 6.5 0.9 8.8 4.6 6.5 1 8.8 4.2 0.4 0 0.4 0.4 52 6 58 305 3 0 2 0 -19.7 0 -19.3 -19.9 02/04/2005 15:00:00 7.2 0.6 8.4 5.3 7.2 0.7 8.8 4.6 0.4 0 0.4 0.4 52 5 62 305 3 0 2 0 -19.7 0.1 -19.5 -19.9 02/04/2005 15:10:00 7 0.6 8.4 5.3 7 0.7 8.8 5.3 0.4 0 0.4 0.4 48 5 47 305 3 0 2 0 -19.8 0 -19.5 -19.9 02/04/2005 15:20:00 7.6 0.6 8.8 5.7 7.6 0.8 8.8 5.3 0.4 0 0.4 0.4 53 4 54 305 3 0 3 0 -19.8 0 -19.5 -19.9 02/04/2005 15:30:00 7.3 0.5 8.4 5.7 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 47 5 47 305 3 0 2 0 -19.7 0 -19.5 -19.9 02/04/2005 15:40:00 7.6 0.6 8.8 5.3 7.7 0.7 8.8 4.9 0.4 0 0.4 0.4 45 5 39 305 3 0 3 0 -19.7 0 -19.3 -19.9 02/04/2005 15:50:00 7.5 0.7 8.8 5.3 7.5 0.8 8.8 5.3 0.4 0 0.4 0.4 40 4 41 305 3 0 2 0 -19.8 0 -19.5 -20.1 02/04/2005 16:00:00 7.2 0.8 8.8 5.3 7.1 0.8 8.8 4.9 0.4 0 0.4 0.4 42 5 43 305 2 0 2 0 -20 0.1 -19.5 -20.1 02/04/2005 16:10:00 7.4 0.7 8.8 5.3 7.4 0.8 8.8 5.3 0.4 0 0.4 0.4 44 5 47 305 2 0 2 0 -20.1 0.1 -19.7 -20.1 02/04/2005 16:20:00 7.7 0.5 8.8 5.7 7.7 0.6 8.8 5.7 0.4 0 0.4 0.4 44 4 44 305 2 0 2 0 -20.1 0 -19.7 -20.1 02/04/2005 16:30:00 7.7 0.4 8.8 6.5 7.8 0.5 9.1 6.1 0.4 0 0.4 0.4 45 5 43 305 2 0 3 0 -20.2 0 -19.9 -20.2 02/04/2005 16:40:00 7.5 0.6 8.8 5.7 7.5 0.7 8.8 5.7 0.4 0 0.4 0.4 49 5 47 305 2 0 2 0 -20.2 0 -19.9 -20.2 02/04/2005 16:50:00 7.2 0.5 8.8 5.7 7.2 0.6 8.8 6.1 0.4 0 0.4 0.4 46 5 44 305 3 0 3 0 -19.9 0 -19.5 -20.1 02/04/2005 17:00:00 7.5 0.7 8.8 5.7 7.5 0.8 9.1 5.7 0.4 0 0.4 0.4 41 5 41 305 2 0 3 0 -20.1 0 -19.5 -20.1 02/04/2005 17:10:00 7.6 0.7 9.1 5.7 7.6 0.7 8.8 5.7 0.4 0 0.4 0.4 44 4 41 305 2 0 2 0 -20.2 0 -19.9 -20.2 02/04/2005 17:20:00 7.3 0.6 8.8 5.7 7.4 0.8 8.8 5.7 0.4 0 0.4 0.4 44 5 45 305 2 0 2 0 -20.2 0 -20.1 -20.2 02/04/2005 17:30:00 7.3 0.8 8.8 4.9 7.2 0.8 9.1 5.7 0.4 0 0.4 0.4 46 6 47 305 2 0 2 0 -20.2 0 -20.1 -20.2 02/04/2005 17:40:00 7.4 0.6 8.8 6.1 7.4 0.6 8.8 5.3 0.4 0 0.4 0.4 47 4 47 305 2 0 2 0 -20.3 0 -20.1 -20.4 02/04/2005 17:50:00 7.9 0.6 9.1 5.7 7.9 0.7 9.1 5.7 0.4 0 0.4 0.4 47 4 48 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/04/2005 18:00:00 8.1 0.5 9.1 6.8 8.2 0.6 9.1 6.5 0.4 0 0.4 0.4 51 3 54 305 2 0 2 0 -20.5 0 -20.2 -20.6 02/04/2005 18:10:00 8.1 0.4 9.1 7.2 8.2 0.5 9.5 6.5 0.4 0 0.4 0.4 51 3 49 305 2 0 2 0 -20.5 0 -20.2 -20.6 02/04/2005 18:20:00 8.5 0.6 9.5 6.8 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 49 3 51 305 2 0 2 0 -20.5 0 -20.2 -20.6 02/04/2005 18:30:00 8 0.5 9.1 6.8 8 0.6 9.5 6.8 0.4 0 0.4 0.4 51 4 45 305 2 0 2 0 -20.6 0.1 -20.2 -20.8 02/04/2005 18:40:00 8.3 0.5 9.5 6.8 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 51 3 51 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/04/2005 18:50:00 7.9 0.5 9.1 6.5 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 48 5 47 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/04/2005 19:00:00 7.8 0.5 9.1 6.1 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 50 4 49 305 2 0 2 0 -20.7 0 -20.6 -20.8 02/04/2005 19:10:00 7.9 0.5 9.1 6.5 7.9 0.5 9.1 6.5 0.4 0 0.4 0.4 46 4 44 305 2 0 2 0 -20.7 0 -20.8 -20.8 02/04/2005 19:20:00 7.9 0.6 9.5 6.1 7.8 0.7 9.1 6.5 0.4 0 0.4 0.4 48 4 44 305 2 0 2 0 -20.8 0 -20.4 -21 02/04/2005 19:30:00 8.1 0.6 9.1 6.5 8 0.6 9.5 6.5 0.4 0 0.4 0.4 52 4 44 305 2 0 2 0 -20.9 0.1 -20.8 -21 02/04/2005 19:40:00 7.8 0.5 9.1 6.5 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 54 4 51 305 2 0 2 0 -21 0 -20.8 -21.1 02/04/2005 19:50:00 7.5 0.5 9.5 6.1 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 55 3 57 305 2 0 2 0 -21 0 -20.8 -21.3 02/04/2005 20:00:00 7.6 0.3 8.4 7.2 7.7 0.3 8.4 6.5 0.4 0 0.4 0.4 56 2 58 305 2 0 2 0 -21 0 -20.6 -21.3 02/04/2005 20:10:00 8.2 0.4 9.1 7.2 8.2 0.4 9.1 6.8 0.4 0 0.4 0.4 56 2 58 305 2 0 2 0 -21 0 -21 -21.3 02/04/2005 20:20:00 8.3 0.3 9.5 7.2 8.5 0.3 9.1 7.2 0.4 0 0.4 0.4 56 2 56 305 2 0 2 0 -21 0 -20.8 -21.1 02/04/2005 20:30:00 8.1 0.4 9.1 6.8 8.1 0.5 9.1 6.8 0.4 0 0.4 0.4 57 3 54 305 2 0 2 0 -20.9 0.1 -20.8 -21.1 02/04/2005 20:40:00 8 0.5 9.1 6.5 7.9 0.5 9.1 6.1 0.4 0 0.4 0.4 58 4 59 305 2 0 2 0 -20.8 0 -20.8 -21 02/04/2005 20:50:00 7.7 0.5 8.8 6.5 7.5 0.5 8.8 6.5 0.4 0 0.4 0.4 61 3 62 305 2 0 2 0 -20.9 0 -20.4 -21.1 02/04/2005 21:00:00 7.3 0.5 8.4 6.1 7.2 0.5 8.8 6.1 0.4 0 0.4 0.4 58 3 58 305 2 0 2 0 -21 0 -20.8 -21.1 02/04/2005 21:10:00 6.7 0.4 8 5.3 6.7 0.4 7.6 5.3 0.4 0 0.4 0.4 59 4 58 305 2 0 2 0 -21 0 -20.8 -21.1 02/04/2005 21:20:00 6.4 0.4 7.6 5.3 6.3 0.4 7.2 5.3 0.4 0 0.4 0.4 58 5 58 305 2 0 2 0 -21 0 -20.8 -21.3 02/04/2005 21:30:00 5.5 0.6 6.8 3.8 5.4 0.7 7.2 3.4 0.4 0 0.4 0.4 48 7 48 305 2 0 2 0 -21.1 0 -20.8 -21.3 02/04/2005 21:40:00 5.7 0.6 6.8 4.2 5.6 0.6 6.8 3.8 0.4 0 0.4 0.4 55 6 57 305 2 0 2 0 -21.1 0.1 -20.8 -21.3 02/04/2005 21:50:00 6.4 0.4 7.2 5.3 6.3 0.4 7.2 5.3 0.4 0 0.4 0.4 60 3 62 305 2 0 2 0 -21.1 0 -20.8 -21.3 02/04/2005 22:00:00 6.7 0.4 7.6 5.3 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 55 3 54 305 2 0 2 0 -21.1 0 -21 -21.3 02/04/2005 22:10:00 6.3 0.5 7.6 4.6 6 0.7 7.2 3.8 0.4 0 0.4 0.4 54 4 55 305 2 0 2 0 -21.2 0 -21.1 -21.3 02/04/2005 22:20:00 6 0.5 7.2 4.2 5.6 0.7 6.8 3.4 0.4 0 0.4 0.4 56 5 62 305 2 0 2 0 -21.3 0 -21.3 -21.5 02/04/2005 22:30:00 5.9 0.8 7.2 3.8 5.5 0.7 7.2 3.8 0.4 0 0.4 0.4 58 5 62 305 2 0 2 0 -21.3 0 -21.3 -21.3 02/04/2005 22:40:00 6.6 0.5 7.6 4.9 6.2 0.6 7.2 4.6 0.4 0 0.4 0.4 58 3 53 305 2 0 2 0 -21.3 0 -21.3 -21.3 02/04/2005 22:50:00 6.6 0.3 7.6 5.3 6.6 0.4 7.6 4.9 0.4 0 0.4 0.4 57 3 54 305 2 0 2 0 -21.2 0 -21 -21.3 02/04/2005 23:00:00 6.3 0.6 7.6 3.4 6 0.7 7.6 3.4 0.4 0 0.4 0.4 59 5 59 305 2 0 2 0 -21.2 0 -21 -21.3 02/04/2005 23:10:00 5.8 0.4 6.8 4.6 5.6 0.4 6.8 4.6 0.4 0 0.4 0.4 60 4 58 305 2 0 2 0 -21.3 0 -21.1 -21.5 02/04/2005 23:20:00 6.2 0.4 7.6 4.9 6 0.5 7.2 4.6 0.4 0 0.4 0.4 62 4 56 305 2 0 2 0 -21.3 0 -21 -21.5 02/04/2005 23:30:00 5.9 0.5 6.8 4.6 5.7 0.5 6.8 4.2 0.4 0 0.4 0.4 53 6 67 305 2 0 2 0 -21.2 0 -21 -21.3 02/04/2005 23:40:00 5.8 0.5 6.8 4.6 5.4 0.6 6.8 4.2 0.4 0 0.4 0.4 47 5 48 305 2 0 2 0 -21.3 0 -21.3 -21.3 02/04/2005 23:50:00 6.2 0.6 8 4.9 5.8 0.6 7.6 4.6 0.4 0 0.4 0.4 51 5 50 305 2 0 2 0 -21.3 0 -21.3 -21.3 02/05/2005 00:00:00 6.8 0.5 8 5.3 6.5 0.6 7.6 4.6 0.4 0 0.4 0.4 55 5 51 305 2 0 2 0 -21.2 0 -21 -21.3 02/05/2005 00:10:00 6.8 0.4 7.6 5.7 6.6 0.5 8 5.3 0.4 0 0.4 0.4 52 4 54 305 2 0 2 0 -21.2 0 -21 -21.3 02/05/2005 00:20:00 6.9 0.4 8 6.1 6.7 0.5 7.6 5.3 0.4 0 0.4 0.4 49 3 47 305 2 0 2 0 -21.2 0 -21 -21.3 02/05/2005 00:30:00 7.1 0.4 8.4 6.1 6.9 0.4 8 5.7 0.4 0 0.4 0.4 49 3 48 305 2 0 2 0 -21.3 0 -21.1 -21.3 02/05/2005 00:40:00 7.1 0.5 8 5.7 6.9 0.5 8 5.7 0.4 0 0.4 0.4 48 4 48 305 2 0 2 0 -21.3 0 -21.3 -21.5 02/05/2005 00:50:00 7 0.5 8 5.7 6.9 0.5 8.4 5.3 0.4 0 0.4 0.4 48 3 52 305 2 0 2 0 -21.3 0 -21.3 -21.5 02/05/2005 01:00:00 6.2 0.5 7.2 4.9 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 50 4 44 305 2 0 2 0 -21.3 0 -21.3 -21.5 02/05/2005 01:10:00 4.8 0.6 6.5 3.4 4.6 0.6 6.1 3 0.4 0 0.4 0.4 52 6 48 305 2 0 2 0 -21.3 0 -21.3 -21.5 02/05/2005 01:20:00 5.1 0.7 6.5 3.4 4.9 0.8 6.5 2.6 0.4 0 0.4 0.4 53 6 53 305 2 0 2 0 -21.3 0 -21.1 -21.3 02/05/2005 01:30:00 5 0.6 6.5 3 4.7 0.7 6.5 2.6 0.4 0 0.4 0.4 56 6 56 305 2 0 2 0 -21.3 0 -21.1 -21.3 02/05/2005 01:40:00 5.5 0.6 6.8 4.2 5.3 0.6 6.5 3.8 0.4 0 0.4 0.4 54 5 53 305 2 0 2 0 -21.3 0 -21.1 -21.3 02/05/2005 01:50:00 5.8 0.7 7.6 3.8 5.6 0.8 7.6 3.4 0.4 0 0.4 0.4 54 5 55 305 2 0 2 0 -21.3 0 -21.3 -21.3 02/05/2005 02:00:00 6 0.6 7.6 4.6 5.7 0.6 7.6 4.6 0.4 0 0.4 0.4 53 6 39 305 2 0 2 0 -21.3 0 -21.1 -21.3 02/05/2005 02:10:00 6.6 0.6 8 4.6 6.3 0.6 7.6 4.9 0.4 0 0.4 0.4 52 5 50 305 2 0 2 0 -21.4 0 -21.3 -21.5 02/05/2005 02:20:00 6.8 0.5 8 5.3 6.6 0.5 7.6 4.9 0.4 0 0.4 0.4 50 4 60 305 2 0 2 0 -21.4 0.1 -21.3 -21.7 02/05/2005 02:30:00 6.8 0.5 8 5.7 6.5 0.5 8 5.3 0.4 0 0.4 0.4 50 4 43 305 2 0 2 0 -21.6 0 -21.3 -21.7 02/05/2005 02:40:00 6.8 0.4 8 5.7 6.5 0.6 7.6 4.9 0.4 0 0.4 0.4 50 4 53 305 2 0 2 0 -21.6 0 -21.1 -21.7 02/05/2005 02:50:00 6.6 0.5 8 5.7 6.5 0.6 8 5.3 0.4 0 0.4 0.4 50 4 50 305 2 0 2 0 -21.6 0 -21.3 -21.8 02/05/2005 03:00:00 6.9 0.5 8.4 5.3 6.8 0.5 8.4 5.7 0.4 0 0.4 0.4 50 4 51 305 2 0 2 0 -21.5 0 -21.3 -21.7 02/05/2005 03:10:00 7.4 0.5 8.8 6.5 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 50 4 52 305 2 0 2 0 -21.5 0 -21.3 -21.7 02/05/2005 03:20:00 7.2 0.6 8.4 5.3 7 0.7 8.8 4.9 0.4 0 0.4 0.4 48 5 47 305 2 0 2 0 -21.6 0.1 -21.3 -21.8 02/05/2005 03:30:00 7.8 0.5 9.1 6.5 7.6 0.5 9.1 5.7 0.4 0 0.4 0.4 48 4 44 305 2 0 2 0 -21.6 0 -21.3 -21.7 02/05/2005 03:40:00 8.2 0.6 9.9 6.8 8 0.6 9.5 6.5 0.4 0 0.4 0.4 47 3 46 305 2 0 2 0 -21.5 0 -21.3 -21.7 02/05/2005 03:50:00 8.3 0.5 9.5 6.5 8.1 0.5 9.5 6.5 0.4 0 0.4 0.4 48 3 42 305 2 0 2 0 -21.6 0 -21.3 -21.7 02/05/2005 04:00:00 8.8 0.6 10.7 7.2 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 47 3 45 305 2 0 2 0 -21.6 0 -21.3 -21.7 02/05/2005 04:10:00 8.3 0.6 9.5 6.5 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 45 4 46 305 2 0 2 0 -21.6 0.1 -21.3 -21.8 02/05/2005 04:20:00 8.2 0.5 9.1 6.5 8 0.6 9.5 6.5 0.4 0 0.4 0.4 45 3 44 305 2 0 2 0 -21.5 0 -21.3 -21.7 02/05/2005 04:30:00 8.5 0.5 9.9 6.8 8.3 0.6 9.9 6.8 0.4 0 0.4 0.4 45 3 44 305 2 0 2 0 -21.6 0 -21.3 -21.7 02/05/2005 04:40:00 8.8 0.6 10.7 6.8 8.7 0.7 10.7 7.2 0.4 0 0.4 0.4 45 4 42 305 2 0 2 0 -21.5 0.1 -21.3 -21.8 02/05/2005 04:50:00 8.9 0.6 10.3 7.2 8.8 0.6 10.7 6.8 0.4 0 0.4 0.4 47 4 41 305 2 0 2 0 -21.4 0.1 -21.3 -21.7 02/05/2005 05:00:00 8.5 0.5 9.9 7.2 8.2 0.6 10.3 6.8 0.4 0 0.4 0.4 47 4 45 305 2 0 2 0 -21.6 0 -21.3 -21.8 02/05/2005 05:10:00 8.1 0.7 9.9 6.1 7.9 0.8 9.5 5.7 0.4 0 0.4 0.4 46 4 41 305 2 0 2 0 -21.6 0 -21.3 -21.8 02/05/2005 05:20:00 8 0.6 9.5 6.5 7.9 0.6 9.1 5.7 0.4 0 0.4 0.4 49 4 57 305 2 0 2 0 -21.6 0 -21.3 -21.7 02/05/2005 05:30:00 7.8 0.6 9.1 6.5 7.6 0.7 9.5 5.7 0.4 0 0.4 0.4 49 4 50 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/05/2005 05:40:00 7.5 0.5 9.5 6.1 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 48 4 47 305 2 0 2 0 -21.7 0 -21.7 -21.8 02/05/2005 05:50:00 8 0.6 9.9 6.5 7.8 0.7 9.9 5.7 0.4 0 0.4 0.4 46 4 50 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/05/2005 06:00:00 7.2 0.5 8.4 6.1 7 0.5 8.4 5.3 0.4 0 0.4 0.4 47 4 51 305 2 0 2 0 -21.7 0 -21.7 -21.8 02/05/2005 06:10:00 6.6 0.5 8 5.3 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 51 5 53 305 2 0 2 0 -21.8 0 -21.7 -21.8 02/05/2005 06:20:00 6.6 0.5 8 4.9 6.4 0.6 7.6 4.9 0.4 0 0.4 0.4 48 5 54 305 2 0 2 0 -21.8 0 -21.7 -21.8 02/05/2005 06:30:00 6.9 0.5 8.4 6.1 6.9 0.5 8 5.3 0.4 0 0.4 0.4 50 4 54 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/05/2005 06:40:00 7.4 0.5 8.8 6.1 7.2 0.5 8.8 6.1 0.4 0 0.4 0.4 50 4 48 305 2 0 2 0 -21.7 0 -21.3 -21.8 02/05/2005 06:50:00 7.2 0.5 8.4 5.3 7.1 0.6 8.4 4.9 0.4 0 0.4 0.4 48 4 44 305 2 0 2 0 -21.6 0 -21.5 -21.8 02/05/2005 07:00:00 6.7 0.5 8 5.3 6.6 0.6 8 4.9 0.4 0 0.4 0.4 46 5 50 305 2 0 2 0 -21.6 0 -21.3 -21.7 02/05/2005 07:10:00 6.9 0.7 8.4 5.3 6.8 0.7 8.4 4.9 0.4 0 0.4 0.4 45 4 39 305 2 0 2 0 -21.6 0 -21.3 -21.7 02/05/2005 07:20:00 7.1 0.7 8.8 5.7 6.9 0.8 9.1 4.6 0.4 0 0.4 0.4 46 4 43 305 2 0 2 0 -21.6 0 -21.3 -21.7 02/05/2005 07:30:00 6.9 0.7 8.4 4.9 6.8 0.8 8.4 4.6 0.4 0 0.4 0.4 47 5 50 305 2 0 2 0 -21.5 0 -21.3 -21.7 02/05/2005 07:40:00 6.3 0.6 8 4.6 6.3 0.7 8 4.6 0.4 0 0.4 0.4 48 5 52 305 2 0 2 0 -21.5 0 -21.3 -21.7 02/05/2005 07:50:00 6.1 0.6 8 4.6 5.9 0.7 7.6 4.2 0.4 0 0.4 0.4 50 5 50 305 2 0 2 0 -21.6 0 -21.3 -21.7 02/05/2005 08:00:00 6.2 0.6 7.6 4.9 6 0.7 7.6 4.2 0.4 0 0.4 0.4 53 5 59 305 2 0 2 0 -21.6 0 -21.5 -21.7 02/05/2005 08:10:00 6.6 0.7 8 4.9 6.6 0.8 8 4.6 0.4 0 0.4 0.4 42 7 38 305 2 0 2 0 -21.5 0.1 -21.3 -21.7 02/05/2005 08:20:00 7.5 0.6 8.8 5.7 7.3 0.7 8.8 5.3 0.4 0 0.4 0.4 41 4 41 305 2 0 2 0 -21.4 0 -21.3 -21.7 02/05/2005 08:30:00 7.6 0.6 8.8 6.1 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 43 4 40 305 2 0 2 0 -21.4 0 -21.3 -21.5 02/05/2005 08:40:00 7.6 0.7 8.8 5.7 7.4 0.8 9.1 5.3 0.4 0 0.4 0.4 43 5 46 305 2 0 2 0 -21.3 0 -21.3 -21.5 02/05/2005 08:50:00 6.9 0.6 8.4 5.3 6.7 0.6 8.4 4.9 0.4 0 0.4 0.4 43 5 46 305 2 0 2 0 -21.3 0 -21.3 -21.5 02/05/2005 09:00:00 7.7 1.1 9.5 4.9 7.5 1.1 9.1 4.9 0.4 0 0.4 0.4 41 5 48 305 2 0 2 0 -21.3 0 -21.1 -21.5 02/05/2005 09:10:00 7 0.8 9.1 4.9 6.9 0.8 9.1 4.9 0.4 0 0.4 0.4 41 5 49 305 2 0 2 0 -21.3 0 -21.1 -21.3 02/05/2005 09:20:00 6.8 0.7 8.8 5.3 6.7 0.7 8.4 5.3 0.4 0 0.4 0.4 40 6 33 305 2 0 2 0 -21.2 0 -21 -21.3 02/05/2005 09:30:00 7.4 0.7 9.1 5.3 7.3 0.9 8.8 4.6 0.4 0 0.4 0.4 38 5 42 305 2 0 2 0 -21.2 0 -21 -21.3 02/05/2005 09:40:00 7.8 0.9 10.3 6.1 7.7 1 10.3 5.7 0.4 0 0.4 0.4 35 5 32 305 2 0 2 0 -21.3 0 -21.1 -21.3 02/05/2005 09:50:00 8.7 0.8 10.7 6.1 8.7 0.9 11.1 6.5 0.4 0 0.4 0.4 38 5 39 305 2 0 2 0 -21.2 0 -21 -21.3 02/05/2005 10:00:00 8.4 0.8 10.3 6.5 8.4 0.8 10.3 6.1 0.4 0 0.4 0.4 38 6 46 305 2 0 2 0 -21 0 -20.8 -21.3 02/05/2005 10:10:00 8.3 0.7 9.9 6.5 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 41 6 44 305 2 0 2 0 -21 0 -20.8 -21.1 02/05/2005 10:20:00 8.2 1 10.3 5.3 8.2 1 9.9 5.3 0.4 0 0.4 0.4 37 6 33 305 2 0 2 0 -21 0 -20.8 -21.1 02/05/2005 10:30:00 8.9 0.9 10.7 6.5 8.7 0.9 11.1 6.5 0.4 0 0.4 0.4 34 6 29 305 2 0 2 0 -21 0 -20.8 -21.3 02/05/2005 10:40:00 8.9 0.7 10.7 6.5 8.9 0.7 10.7 6.8 0.4 0 0.4 0.4 34 6 28 305 2 0 2 0 -21.1 0 -20.8 -21.3 02/05/2005 10:50:00 8.7 0.7 10.3 6.5 8.7 0.7 10.3 6.5 0.4 0 0.4 0.4 32 4 31 305 2 0 2 0 -21.1 0 -21 -21.3 02/05/2005 11:00:00 8.3 0.9 9.9 5.7 8.2 0.9 10.3 5.7 0.4 0 0.4 0.4 33 6 31 305 2 0 2 0 -21.1 0 -21 -21.3 02/05/2005 11:10:00 8.7 0.7 9.9 6.8 8.7 0.7 10.3 6.5 0.4 0 0.4 0.4 39 4 44 305 2 0 2 0 -21.1 0 -20.8 -21.3 02/05/2005 11:20:00 8.7 0.7 10.3 6.5 8.8 0.8 10.7 6.5 0.4 0 0.4 0.4 38 5 35 305 2 0 2 0 -21.1 0 -21 -21.3 02/05/2005 11:30:00 8.2 0.8 9.9 6.1 8.2 0.8 9.9 5.7 0.4 0 0.4 0.4 42 5 34 305 2 0 2 0 -21 0 -20.8 -21.3 02/05/2005 11:40:00 7.4 0.7 9.5 5.7 7.4 0.8 9.5 5.7 0.4 0 0.4 0.4 42 6 44 305 2 0 2 0 -21 0 -20.8 -21.1 02/05/2005 11:50:00 7.3 0.6 8.8 4.9 7.3 0.7 9.1 5.3 0.4 0 0.4 0.4 42 5 33 305 2 0 2 0 -21 0 -20.8 -21.1 02/05/2005 12:00:00 7.1 0.6 8.8 5.7 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 39 5 39 305 2 0 2 0 -21 0 -20.8 -21.1 02/05/2005 12:10:00 7 0.7 8.8 5.3 7.1 0.7 9.1 5.3 0.4 0 0.4 0.4 37 6 36 305 2 0 2 0 -20.9 0 -20.8 -21.1 02/05/2005 12:20:00 8 0.6 9.1 5.7 8 0.7 9.5 6.1 0.4 0 0.4 0.4 37 5 38 305 2 0 2 0 -21 0 -20.8 -21.1 02/05/2005 12:30:00 7.6 0.9 9.1 4.9 7.7 0.9 9.5 4.9 0.4 0 0.4 0.4 38 5 46 305 2 0 2 0 -21 0 -20.8 -21.1 02/05/2005 12:40:00 7.8 0.6 9.1 5.7 8 0.6 9.1 6.1 0.4 0 0.4 0.4 38 4 41 305 2 0 2 0 -21 0 -20.8 -21.1 02/05/2005 12:50:00 8.2 0.5 9.5 6.5 8.3 0.6 9.5 6.1 0.4 0 0.4 0.4 38 3 33 305 2 0 2 0 -21 0 -20.8 -21.1 02/05/2005 13:00:00 8 0.5 9.5 6.8 8.2 0.5 9.5 6.5 0.4 0 0.4 0.4 38 5 40 305 2 0 2 0 -20.9 0 -20.8 -21.1 02/05/2005 13:10:00 8 0.6 9.1 6.1 8 0.8 9.5 6.1 0.4 0 0.4 0.4 37 5 37 305 2 0 2 0 -20.8 0 -20.8 -21 02/05/2005 13:20:00 8.4 0.6 9.9 6.1 8.4 0.7 9.9 6.5 0.4 0 0.4 0.4 38 4 37 305 2 0 2 0 -20.8 0 -20.8 -21 02/05/2005 13:30:00 8.5 0.6 9.9 6.5 8.5 0.7 9.9 6.5 0.4 0 0.4 0.4 40 4 39 305 2 0 2 0 -20.7 0 -20.6 -20.8 02/05/2005 13:40:00 8.2 0.7 9.9 6.5 8.4 0.7 10.3 6.8 0.4 0 0.4 0.4 42 5 36 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/05/2005 13:50:00 7.4 0.6 9.1 5.7 7.4 0.7 9.5 6.1 0.4 0 0.4 0.4 40 6 39 305 2 0 2 0 -20.5 0.1 -20.1 -20.8 02/05/2005 14:00:00 8 0.7 9.5 6.1 8.1 0.8 9.9 5.7 0.4 0 0.4 0.4 41 5 45 305 2 0 2 0 -20.6 0.1 -20.2 -20.8 02/05/2005 14:10:00 8.3 0.6 9.9 6.8 8.3 0.7 10.3 6.8 0.4 0 0.4 0.4 39 6 39 305 2 0 2 0 -20.6 0.1 -20.1 -20.8 02/05/2005 14:20:00 8.4 0.8 9.9 6.5 8.4 0.8 10.3 6.8 0.4 0 0.4 0.4 38 6 41 305 2 0 2 0 -20.6 0.1 -20.1 -20.8 02/05/2005 14:30:00 8.2 0.5 9.5 6.8 8.3 0.6 9.5 6.5 0.4 0 0.4 0.4 43 5 40 305 2 0 2 0 -20.5 0.1 -20.1 -20.8 02/05/2005 14:40:00 8.9 0.8 10.3 6.5 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 40 5 42 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/05/2005 14:50:00 9.7 0.7 11.8 7.6 9.7 0.7 11.5 7.6 0.4 0 0.4 0.4 39 4 43 305 2 0 2 0 -20.3 0 -20.1 -20.6 02/05/2005 15:00:00 9.9 0.6 11.5 8.4 9.8 0.7 11.5 7.6 0.4 0 0.4 0.4 38 4 37 305 2 0 2 0 -20.3 0 -20.1 -20.4 02/05/2005 15:10:00 9.9 0.8 11.8 7.6 9.9 0.9 12.2 7.6 0.4 0 0.4 0.4 38 5 45 305 2 0 2 0 -20.2 0 -19.9 -20.2 02/05/2005 15:20:00 10.3 1.2 13 7.6 10.2 1.3 13.3 6.8 0.4 0 0.4 0.4 43 6 48 305 2 0 2 0 -20.2 0 -19.9 -20.4 02/05/2005 15:30:00 11.3 0.8 13 9.1 11.4 0.9 13.3 8.4 0.4 0 0.4 0.4 46 4 53 305 2 0 2 0 -20.3 0 -20.1 -20.4 02/05/2005 15:40:00 10.5 0.9 12.2 8 10.4 1 12.6 8.4 0.4 0 0.4 0.4 44 6 49 305 2 0 2 0 -20.2 0 -19.9 -20.4 02/05/2005 15:50:00 10.6 1 12.6 8.4 10.6 1 12.6 7.6 0.4 0 0.4 0.4 41 6 35 305 2 0 2 0 -20.3 0 -20.1 -20.4 02/05/2005 16:00:00 10.6 0.8 12.6 8 10.5 1 13 8 0.4 0 0.4 0.4 43 5 50 305 2 0 2 0 -20.3 0 -20.1 -20.4 02/05/2005 16:10:00 10.6 1.2 13 7.6 10.7 1.3 13 7.6 0.4 0 0.4 0.4 44 5 43 305 2 0 2 0 -20.5 0 -20.2 -20.8 02/05/2005 16:20:00 11.2 0.8 13 8.4 11.2 1 13.7 8.8 0.4 0 0.4 0.4 44 5 50 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/05/2005 16:30:00 11 1.1 13 8 10.8 1.2 13.7 6.8 0.4 0 0.4 0.4 45 5 47 305 2 0 2 0 -20.5 0 -20.2 -20.6 02/05/2005 16:40:00 11.4 0.8 13 8.8 11.4 0.9 13 8.8 0.4 0 0.4 0.4 43 4 43 305 2 0 2 0 -20.5 0 -20.2 -20.6 02/05/2005 16:50:00 11.1 1 13.7 8.8 11 1 13.7 8.8 0.4 0 0.4 0.4 36 4 43 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/05/2005 17:00:00 10.7 1.2 13.3 8.4 10.8 1.2 13.3 8 0.4 0 0.4 0.4 38 5 29 305 2 0 2 0 -20.4 0 -20.1 -20.8 02/05/2005 17:10:00 10.5 1 13 8.4 10.4 1 12.6 8.4 0.4 0 0.4 0.4 41 5 45 305 2 0 2 0 -20.6 0 -20.2 -20.8 02/05/2005 17:20:00 11.5 0.8 13.3 9.1 11.4 1.1 13.7 8.8 0.4 0 0.4 0.4 35 5 37 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/05/2005 17:30:00 11 1.2 13.3 7.6 10.8 1.3 13.3 7.6 0.4 0 0.4 0.4 35 6 36 305 2 0 2 0 -20.5 0 -20.2 -20.8 02/05/2005 17:40:00 11.5 1 13.3 8.8 11.2 1.1 13.3 8 0.4 0 0.4 0.4 33 5 29 305 2 0 2 0 -20.5 0 -20.2 -20.8 02/05/2005 17:50:00 11.6 1.1 13.7 8.8 11.4 1.2 14.1 8.8 0.4 0 0.4 0.4 35 6 25 305 2 0 2 0 -20.5 0 -20.2 -20.6 02/05/2005 18:00:00 11.9 1 13.7 8.8 11.8 1.2 14.1 8.8 0.4 0 0.4 0.4 39 6 42 305 2 0 2 0 -20.5 0 -20.1 -20.8 02/05/2005 18:10:00 12.2 1.3 14.9 8.4 12.1 1.2 15.3 9.1 0.4 0 0.4 0.4 35 5 42 305 2 0 2 0 -20.5 0 -20.2 -20.8 02/05/2005 18:20:00 13.2 1.1 15.6 9.9 13.1 1.3 16.1 9.5 0.4 0 0.4 0.4 36 5 35 305 2 0 2 0 -20.5 0.1 -20.1 -20.8 02/05/2005 18:30:00 13.6 1.1 16.1 10.3 13.6 1.2 16.1 9.5 0.4 0 0.4 0.4 40 5 34 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/05/2005 18:40:00 13.1 1 15.3 9.9 13.1 1 15.3 10.3 0.4 0 0.4 0.4 45 5 46 305 2 0 2 0 -20.3 0 -20.1 -20.6 02/05/2005 18:50:00 12.7 1.2 15.3 9.1 12.6 1.3 15.6 9.5 0.4 0 0.4 0.4 39 5 33 305 2 0 2 0 -20.2 0 -19.9 -20.2 02/05/2005 19:00:00 12.7 1 14.9 9.9 12.6 1.1 15.3 9.9 0.4 0 0.4 0.4 40 5 43 305 2 0 2 0 -20.2 0 -19.9 -20.2 02/05/2005 19:10:00 13.1 1 15.3 9.5 13.1 1.1 15.6 9.1 0.4 0 0.4 0.4 40 4 41 305 2 0 2 0 -20.2 0 -20.1 -20.4 02/05/2005 19:20:00 13.1 1.1 15.6 9.5 13 1.2 15.6 9.5 0.4 0 0.4 0.4 39 5 39 305 2 0 2 0 -20.3 0 -20.1 -20.4 02/05/2005 19:30:00 13.4 0.9 15.3 10.3 13.3 1.1 15.3 9.5 0.4 0 0.4 0.4 38 3 37 305 2 0 2 0 -20.3 0 -20.1 -20.6 02/05/2005 19:40:00 13.5 0.9 16.4 11.1 13.6 0.9 16.8 11.5 0.4 0 0.4 0.4 47 4 46 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/05/2005 19:50:00 13.2 1.1 16.1 9.9 13.1 1.2 16.4 9.9 0.4 0 0.4 0.4 45 5 38 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/05/2005 20:00:00 13.4 1 15.3 9.9 13.3 1 15.6 9.9 0.4 0 0.4 0.4 43 4 48 305 2 0 2 0 -20.5 0 -20.1 -20.6 02/05/2005 20:10:00 12.7 1 14.9 10.3 12.6 1.1 15.6 9.9 0.4 0 0.4 0.4 39 5 45 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/05/2005 20:20:00 12.6 1 15.3 9.9 12.5 1 14.9 9.5 0.4 0 0.4 0.4 38 5 29 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/05/2005 20:30:00 12.8 1 15.3 9.5 12.7 1 15.6 9.5 0.4 0 0.4 0.4 37 5 38 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/05/2005 20:40:00 13.3 0.9 15.3 11.1 13.3 1 15.6 10.7 0.4 0 0.4 0.4 41 5 40 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/05/2005 20:50:00 13.1 1 15.6 10.3 13 1.1 15.6 9.9 0.4 0 0.4 0.4 44 4 46 305 2 0 2 0 -20.3 0 -20.1 -20.6 02/05/2005 21:00:00 13.4 1.3 16.1 9.9 13.3 1.3 16.4 10.3 0.4 0 0.4 0.4 41 5 40 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/05/2005 21:10:00 14.2 1.1 16.4 10.7 14 1.2 16.4 10.3 0.4 0 0.4 0.4 39 5 41 305 2 0 2 0 -20.5 0 -20.1 -20.6 02/05/2005 21:20:00 13.8 1 16.4 10.3 13.6 1.2 16.4 9.5 0.4 0 0.4 0.4 37 6 33 305 2 0 2 0 -20.3 0 -20.1 -20.6 02/05/2005 21:30:00 14.1 1.3 16.4 10.7 13.9 1.4 16.4 9.9 0.4 0 0.4 0.4 39 5 35 305 2 0 2 0 -20.4 0 -20.2 -20.6 02/05/2005 21:40:00 14.3 1.2 17.2 11.5 14.2 1.3 17.2 11.5 0.4 0 0.4 0.4 42 5 42 305 2 0 2 0 -20.3 0 -20.1 -20.6 02/05/2005 21:50:00 14.3 1.3 17.2 10.7 14.2 1.3 17.6 11.5 0.4 0 0.4 0.4 40 5 39 305 2 0 2 0 -20.3 0 -20.1 -20.4 02/05/2005 22:00:00 14.8 1 17.2 11.5 14.7 1.1 17.6 11.5 0.4 0 0.4 0.4 38 5 30 305 2 0 2 0 -20.2 0 -20.1 -20.4 02/05/2005 22:10:00 14.3 1.2 17.2 11.5 14.1 1.2 17.2 11.5 0.4 0 0.4 0.4 37 6 36 305 3 0 2 0 -20.2 0 -20.1 -20.2 02/05/2005 22:20:00 13.6 1.1 16.1 10.7 13.4 1.2 16.4 10.3 0.4 0 0.4 0.4 39 6 28 305 3 0 2 0 -20.2 0 -20.1 -20.2 02/05/2005 22:30:00 13.3 1.5 17.2 10.3 13.2 1.5 17.6 9.9 0.4 0 0.4 0.4 38 5 35 305 3 0 2 0 -20.2 0 -20.1 -20.4 02/05/2005 22:40:00 13.8 1.2 16.4 10.7 13.6 1.4 16.4 9.9 0.4 0 0.4 0.4 39 5 33 305 3 0 3 0 -20.4 0 -20.1 -20.6 02/05/2005 22:50:00 14.2 1.2 16.8 11.5 14 1.3 17.2 11.1 0.4 0 0.4 0.4 40 6 35 305 2 0 2 0 -20.5 0 -20.1 -20.8 02/05/2005 23:00:00 13.5 1.2 16.1 10.7 13.4 1.3 16.4 10.7 0.4 0 0.4 0.4 45 5 47 305 2 0 2 0 -20.7 0 -20.4 -20.8 02/05/2005 23:10:00 14.8 1.2 17.9 12.2 14.7 1.3 18.3 11.1 0.4 0 0.4 0.4 44 4 40 305 2 0 2 0 -20.8 0.1 -20.4 -21.1 02/05/2005 23:20:00 14 1.6 17.2 10.3 13.9 1.7 17.9 9.9 0.4 0 0.4 0.4 43 5 45 305 2 0 2 0 -20.8 0 -20.6 -21 02/05/2005 23:30:00 14.3 1.3 17.2 11.1 14.1 1.3 17.2 11.1 0.4 0 0.4 0.4 44 5 47 305 2 0 2 0 -20.8 0 -20.6 -21 02/05/2005 23:40:00 14.1 1.2 17.2 9.9 14 1.3 17.6 9.5 0.4 0 0.4 0.4 44 4 45 305 2 0 2 0 -20.9 0 -20.8 -21.1 02/05/2005 23:50:00 13.7 1 16.1 11.5 13.4 1.1 16.4 11.1 0.4 0 0.4 0.4 40 5 39 305 2 0 2 0 -20.9 0 -20.8 -21.1 02/06/2005 00:00:00 13.6 1 16.8 11.1 13.5 1.1 16.4 10.3 0.4 0 0.4 0.4 43 5 42 305 2 0 2 0 -20.9 0.1 -20.6 -21.1 02/06/2005 00:10:00 12.8 1.3 16.1 9.5 12.8 1.3 16.1 9.5 0.4 0 0.4 0.4 41 4 39 305 2 0 2 0 -20.7 0 -20.6 -20.8 02/06/2005 00:20:00 13.9 1.1 16.1 10.7 13.8 1.2 16.4 9.9 0.4 0 0.4 0.4 37 5 38 305 2 0 2 0 -20.8 0 -20.6 -21 02/06/2005 00:30:00 14.8 1.2 17.2 11.5 14.5 1.4 17.6 10.3 0.4 0 0.4 0.4 36 5 29 305 2 0 2 0 -20.8 0 -20.6 -21 02/06/2005 00:40:00 13.9 1.3 17.2 10.7 13.7 1.3 16.4 9.5 0.4 0 0.4 0.4 38 6 27 305 2 0 2 0 -20.7 0 -20.4 -20.8 02/06/2005 00:50:00 14 1.2 17.2 10.7 13.9 1.4 17.2 10.3 0.4 0 0.4 0.4 37 6 37 305 2 0 2 0 -20.7 0 -20.4 -20.8 02/06/2005 01:00:00 14.6 1 16.8 10.7 14.3 1.2 17.2 10.3 0.4 0 0.4 0.4 33 5 31 305 2 0 2 0 -20.7 0 -20.6 -21 02/06/2005 01:10:00 14.6 1.1 16.8 11.1 14.3 1.1 16.8 11.1 0.4 0 0.4 0.4 31 5 33 305 2 0 2 0 -20.7 0 -20.6 -20.8 02/06/2005 01:20:00 13.9 1.2 16.8 10.7 13.6 1.3 16.8 9.9 0.4 0 0.4 0.4 31 5 34 305 2 0 2 0 -20.7 0 -20.4 -20.8 02/06/2005 01:30:00 14.9 1.2 17.2 11.1 14.6 1.3 17.2 10.3 0.4 0 0.4 0.4 29 5 27 305 2 0 2 0 -20.7 0 -20.6 -21 02/06/2005 01:40:00 14.7 1.2 17.6 11.1 14.4 1.3 16.8 10.3 0.4 0 0.4 0.4 30 5 32 305 2 0 2 0 -20.7 0 -20.4 -21 02/06/2005 01:50:00 15.1 1.2 17.6 10.7 14.7 1.3 17.2 10.3 0.4 0 0.4 0.4 26 4 24 305 2 0 2 0 -21 0.1 -20.6 -21.3 02/06/2005 02:00:00 14.9 1.3 17.2 10.3 14.5 1.3 17.6 10.7 0.4 0 0.4 0.4 25 5 27 305 2 0 2 0 -21.1 0 -21 -21.3 02/06/2005 02:10:00 14.2 1.3 17.2 10.7 14 1.3 16.8 10.7 0.4 0 0.4 0.4 26 5 29 305 2 0 2 0 -21.2 0 -21 -21.3 02/06/2005 02:20:00 14.3 1.2 17.2 10.7 14 1.3 17.2 10.7 0.4 0 0.4 0.4 27 5 26 305 2 0 2 0 -21.4 0.1 -21 -21.7 02/06/2005 02:30:00 14.7 1.2 16.8 11.5 14.3 1.3 16.8 10.7 0.4 0 0.4 0.4 26 5 23 305 2 0 2 0 -21.5 0 -21 -21.7 02/06/2005 02:40:00 15.4 1.1 17.9 11.8 15.2 1.2 17.6 11.8 0.4 0 0.4 0.4 24 5 25 305 2 0 2 0 -21.7 0.1 -21.3 -21.8 02/06/2005 02:50:00 15.7 1.3 18.3 11.8 15.4 1.3 18.3 11.8 0.4 0 0.4 0.4 25 5 22 305 2 0 2 0 -21.8 0 -21.3 -22 02/06/2005 03:00:00 15.5 1.3 18.3 11.8 15.3 1.3 18.3 11.8 0.4 0 0.4 0.4 26 6 31 305 2 0 2 0 -21.9 0.1 -21.7 -22.2 02/06/2005 03:10:00 15.7 1.2 19.1 12.6 15.4 1.3 18.7 11.5 0.4 0 0.4 0.4 25 5 29 305 2 0 2 0 -22.1 0.1 -21.8 -22.4 02/06/2005 03:20:00 17.6 1.1 19.9 13.3 17.1 1.2 19.9 13 0.4 0 0.4 0.4 25 4 25 305 2 0 2 0 -22.3 0 -22 -22.5 02/06/2005 03:30:00 16.4 1.4 19.9 12.2 16 1.5 19.9 10.3 0.4 0 0.4 0.4 29 5 32 305 2 0 2 0 -22 0 -21.8 -22.2 02/06/2005 03:40:00 16.2 1.4 19.5 13 15.8 1.3 18.7 12.2 0.4 0 0.4 0.4 28 5 27 305 2 0 2 0 -22.2 0.1 -21.8 -22.4 02/06/2005 03:50:00 16.8 1.2 19.5 13 16.4 1.3 19.5 13 0.4 0 0.4 0.4 29 5 24 305 2 0 2 0 -22.4 0 -22.2 -22.5 02/06/2005 04:00:00 16.6 1.5 19.5 12.2 16.2 1.5 19.5 12.6 0.4 0 0.4 0.4 29 5 34 305 2 0 2 0 -22.3 0.1 -21.8 -22.5 02/06/2005 04:10:00 15.9 1.5 18.7 11.8 15.6 1.5 19.1 11.1 0.4 0 0.4 0.4 31 5 32 305 2 0 2 0 -22.3 0 -21.8 -22.5 02/06/2005 04:20:00 16.4 1.4 19.5 12.6 16 1.3 19.5 12.2 0.4 0 0.4 0.4 29 4 31 305 2 0 2 0 -22.3 0 -21.8 -22.5 02/06/2005 04:30:00 16.8 1.1 19.1 13.7 16.4 1.2 19.1 13.3 0.4 0 0.4 0.4 27 4 24 305 2 0 2 0 -22.1 0 -21.7 -22.2 02/06/2005 04:40:00 15.8 1.7 19.1 11.8 15.5 1.7 18.7 11.1 0.4 0 0.4 0.4 27 5 25 305 2 0 2 0 -22.1 0 -21.7 -22.2 02/06/2005 04:50:00 15.7 1.2 18.7 12.2 15.4 1.2 18.3 12.2 0.4 0 0.4 0.4 27 5 23 305 2 0 2 0 -22.1 0 -21.7 -22.2 02/06/2005 05:00:00 16.1 1.3 19.1 12.2 15.8 1.4 18.7 11.8 0.4 0 0.4 0.4 28 5 23 305 2 0 2 0 -22.1 0 -21.8 -22.2 02/06/2005 05:10:00 16.1 1.3 19.1 12.6 15.8 1.4 18.7 12.2 0.4 0 0.4 0.4 26 5 28 305 2 0 2 0 -22.1 0 -21.8 -22.2 02/06/2005 05:20:00 15.7 1.7 19.9 12.2 15.2 1.6 19.5 11.1 0.4 0 0.4 0.4 29 5 21 305 2 0 2 0 -21.9 0 -21.5 -22 02/06/2005 05:30:00 16.3 1.5 19.5 12.6 16 1.5 19.5 12.2 0.4 0 0.4 0.4 33 5 32 305 2 0 2 0 -21.8 0 -21.8 -22 02/06/2005 05:40:00 15.7 1.1 18.3 12.2 15.4 1.2 18.3 12.2 0.4 0 0.4 0.4 32 5 35 305 2 0 2 0 -22 0 -21.3 -22 02/06/2005 05:50:00 14.8 1.3 17.6 11.8 14.5 1.3 17.6 11.1 0.4 0 0.4 0.4 28 5 27 305 2 0 2 0 -22.2 0.1 -21.8 -22.4 02/06/2005 06:00:00 15.6 1.6 19.9 11.5 15.2 1.7 19.5 11.5 0.4 0 0.4 0.4 30 5 22 305 2 0 2 0 -22.3 0 -22 -22.5 02/06/2005 06:10:00 16.7 1.5 20.2 13 16.1 1.6 19.5 11.8 0.4 0 0.4 0.4 29 5 27 305 2 0 2 0 -22.4 0 -22.2 -22.5 02/06/2005 06:20:00 16.6 1.3 19.9 12.6 16.2 1.3 19.9 12.2 0.4 0 0.4 0.4 28 4 27 305 2 0 2 0 -22.5 0 -22.4 -22.5 02/06/2005 06:30:00 15.9 1.5 19.1 12.2 15.5 1.5 18.7 11.5 0.4 0 0.4 0.4 28 4 25 305 2 0 2 0 -22.7 0 -22.5 -22.9 02/06/2005 06:40:00 16.6 1.2 19.1 13.3 16.1 1.3 18.7 12.6 0.4 0 0.4 0.4 28 5 24 305 2 0 2 0 -22.8 0 -22.5 -22.9 02/06/2005 06:50:00 14.7 1.5 18.3 10.3 14.3 1.5 17.6 10.3 0.4 0 0.4 0.4 31 5 31 305 2 0 1 0 -22.8 0 -22.5 -22.9 02/06/2005 07:00:00 14.5 1.5 17.6 11.1 14.1 1.5 17.2 10.7 0.4 0 0.4 0.4 29 5 27 305 2 0 2 0 -22.7 0 -22.5 -22.9 02/06/2005 07:10:00 14.8 1.3 17.6 11.1 14.5 1.3 17.9 11.8 0.4 0 0.4 0.4 27 5 29 305 2 0 2 0 -22.7 0 -22.5 -22.9 02/06/2005 07:20:00 15.6 1.5 18.7 11.8 15.2 1.5 18.3 11.5 0.4 0 0.4 0.4 28 6 29 305 2 0 2 0 -22.7 0.1 -22.2 -22.9 02/06/2005 07:30:00 16.1 1.5 19.5 12.6 15.8 1.5 19.5 11.1 0.4 0 0.4 0.4 29 5 26 305 2 0 2 0 -22.7 0 -22.5 -22.9 02/06/2005 07:40:00 16.1 1.4 19.1 12.2 15.7 1.4 18.7 11.8 0.4 0 0.4 0.4 32 4 33 305 2 0 2 0 -22.7 0 -22.5 -22.9 02/06/2005 07:50:00 15.6 1.7 19.5 11.5 15.1 1.7 19.5 10.3 0.4 0 0.4 0.4 30 5 25 305 2 0 2 0 -22.8 0 -22.5 -22.9 02/06/2005 08:00:00 15.7 1.8 19.1 11.5 15.3 2 19.1 11.1 0.4 0 0.4 0.4 31 5 36 305 2 0 2 0 -22.8 0 -22.4 -22.9 02/06/2005 08:10:00 16.7 1.3 19.1 12.6 16.2 1.3 19.9 12.6 0.4 0 0.4 0.4 33 5 39 305 2 0 2 0 -22.8 0 -22.4 -22.9 02/06/2005 08:20:00 15.6 1.7 19.5 11.1 15.4 1.8 19.5 10.3 0.4 0 0.4 0.4 34 5 37 305 2 0 2 0 -22.8 0 -22.4 -23 02/06/2005 08:30:00 14.6 1.5 17.9 10.7 14.4 1.5 17.9 11.5 0.4 0 0.4 0.4 34 5 32 305 2 0 2 0 -22.9 0 -22.4 -23 02/06/2005 08:40:00 16.1 1.2 19.1 12.6 15.9 1.3 19.5 11.5 0.4 0 0.4 0.4 36 5 40 305 2 0 2 0 -22.9 0 -22.5 -23.2 02/06/2005 08:50:00 16.1 1.7 20.2 11.8 15.7 1.6 19.9 10.7 0.4 0 0.4 0.4 34 5 42 305 2 0 2 0 -22.9 0 -22.4 -22.9 02/06/2005 09:00:00 16.4 1.5 19.5 11.5 16 1.4 19.1 12.2 0.4 0 0.4 0.4 34 5 32 305 2 0 1 0 -22.9 0 -22.4 -23 02/06/2005 09:10:00 16 1.5 19.1 11.5 15.6 1.5 19.1 11.8 0.4 0 0.4 0.4 32 5 31 305 2 0 2 0 -22.8 0 -22.4 -22.9 02/06/2005 09:20:00 15.3 1.8 19.5 10.7 15 1.8 19.5 11.5 0.4 0 0.4 0.4 28 4 32 305 2 0 2 0 -22.7 0 -22.4 -22.9 02/06/2005 09:30:00 14.7 1.5 18.7 10.7 14.2 1.5 17.9 9.9 0.4 0 0.4 0.4 28 5 25 305 2 0 1 0 -22.7 0 -22.5 -22.9 02/06/2005 09:40:00 14.9 1.2 17.2 12.2 14.4 1.3 17.2 11.5 0.4 0 0.4 0.4 28 5 36 305 2 0 2 0 -22.7 0 -22.5 -22.7 02/06/2005 09:50:00 14.6 1.3 17.6 11.1 14.3 1.3 17.2 9.9 0.4 0 0.4 0.4 27 5 30 305 2 0 2 0 -22.6 0 -22.5 -22.7 02/06/2005 10:00:00 14.8 1.5 17.9 10.7 14.4 1.5 17.6 10.7 0.4 0 0.4 0.4 27 5 27 305 2 0 1 0 -22.4 0.1 -21.8 -22.5 02/06/2005 10:10:00 15.1 1.3 18.3 11.8 14.6 1.3 17.6 11.5 0.4 0 0.4 0.4 29 5 30 305 2 0 1 0 -22.4 0 -21.8 -22.5 02/06/2005 10:20:00 12.8 1.5 16.1 9.1 12.7 1.6 16.4 9.1 0.4 0 0.4 0.4 27 6 36 305 2 0 2 0 -22.3 0 -21.8 -22.5 02/06/2005 10:30:00 13.7 1.3 16.8 10.3 13.3 1.3 16.4 9.5 0.4 0 0.4 0.4 27 6 36 305 2 0 2 0 -22.3 0 -21.8 -22.5 02/06/2005 10:40:00 13.3 1 15.6 11.1 13 1 16.1 10.3 0.4 0 0.4 0.4 29 6 40 305 2 0 2 0 -22.3 0 -21.8 -22.5 02/06/2005 10:50:00 14.1 1.1 16.4 10.7 13.7 1.2 16.8 10.7 0.4 0 0.4 0.4 31 5 35 305 2 0 2 0 -22.4 0 -21.8 -22.5 02/06/2005 11:00:00 13.8 1.2 16.8 10.7 13.5 1.3 16.8 10.3 0.4 0 0.4 0.4 32 5 27 305 2 0 2 0 -22.4 0 -22.2 -22.5 02/06/2005 11:10:00 14.9 1.2 17.2 11.5 14.5 1.1 17.2 11.1 0.4 0 0.4 0.4 30 5 27 305 2 0 2 0 -22.3 0 -22.2 -22.5 02/06/2005 11:20:00 14.2 1.2 17.2 11.5 13.8 1.2 16.8 11.1 0.4 0 0.4 0.4 29 5 32 305 2 0 2 0 -22.3 0 -22 -22.4 02/06/2005 11:30:00 13.5 1.3 17.2 10.7 13.2 1.3 17.2 9.9 0.4 0 0.4 0.4 33 6 36 305 2 0 2 0 -22.3 0 -22 -22.4 02/06/2005 11:40:00 13.4 1.2 16.8 10.3 13.2 1.3 16.8 9.9 0.4 0 0.4 0.4 32 5 35 305 2 0 2 0 -22.3 0 -21.8 -22.4 02/06/2005 11:50:00 13.1 1.1 15.3 9.9 12.8 1.1 15.3 10.3 0.4 0 0.4 0.4 29 5 27 305 2 0 2 0 -22.2 0 -22 -22.4 02/06/2005 12:00:00 13.8 1.3 17.6 10.3 13.5 1.4 16.8 10.3 0.4 0 0.4 0.4 30 4 27 305 2 0 2 0 -22.1 0 -22 -22.4 02/06/2005 12:10:00 14.7 1.3 18.7 11.1 14.2 1.3 18.7 11.1 0.4 0 0.4 0.4 29 4 30 305 2 0 2 0 -22 0 -21.8 -22.2 02/06/2005 12:20:00 15.2 1.5 17.9 10.3 14.8 1.5 18.3 10.3 0.4 0 0.4 0.4 28 4 26 305 2 0 2 0 -22 0 -21.8 -22.2 02/06/2005 12:30:00 15.3 1.4 18.3 10.7 14.9 1.5 18.3 11.5 0.4 0 0.4 0.4 29 5 37 305 2 0 2 0 -22 0 -21.8 -22.2 02/06/2005 12:40:00 14.2 1.5 18.3 11.1 13.8 1.5 18.7 10.7 0.4 0 0.4 0.4 30 5 30 305 2 0 2 0 -21.9 0 -21.7 -22 02/06/2005 12:50:00 15.5 1.4 18.7 11.5 15 1.5 18.3 11.1 0.4 0 0.4 0.4 30 5 26 305 2 0 2 0 -21.8 0 -21.7 -21.8 02/06/2005 13:00:00 16.3 1.2 18.7 12.2 15.8 1.3 18.7 12.2 0.4 0 0.4 0.4 31 4 30 305 2 0 2 0 -21.8 0 -21.5 -22 02/06/2005 13:10:00 15.7 1.5 18.3 11.1 15.3 1.5 18.7 12.2 0.4 0 0.4 0.4 28 5 27 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/06/2005 13:20:00 14.8 1.5 18.3 12.2 14.5 1.5 17.9 11.5 0.4 0 0.4 0.4 26 4 26 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/06/2005 13:30:00 14.4 1.5 17.6 11.1 14.1 1.5 18.3 10.3 0.4 0 0.4 0.4 28 5 33 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/06/2005 13:40:00 15.4 1.2 17.9 11.5 15.1 1.3 17.9 11.1 0.4 0 0.4 0.4 31 4 35 305 2 0 2 0 -21.7 0 -21.3 -21.8 02/06/2005 13:50:00 15 1 16.8 11.8 14.9 1 16.8 11.8 0.4 0 0.4 0.4 33 4 30 305 2 0 2 0 -21.8 0 -21.7 -21.8 02/06/2005 14:00:00 13.7 1.3 16.8 9.9 13.5 1.3 16.4 9.9 0.4 0 0.4 0.4 30 5 25 305 2 0 2 0 -21.7 0 -21.3 -21.8 02/06/2005 14:10:00 13.4 1 16.4 11.1 13.1 1.1 16.1 10.3 0.4 0 0.4 0.4 29 5 28 305 2 0 2 0 -21.5 0 -21.3 -21.7 02/06/2005 14:20:00 13.4 1.1 16.1 11.1 13.2 1.2 16.1 10.7 0.4 0 0.4 0.4 31 5 29 305 2 0 3 0 -21.3 0 -21 -21.5 02/06/2005 14:30:00 15.4 1 18.3 12.6 15.1 1.1 17.9 12.6 0.4 0 0.4 0.4 27 5 29 305 2 0 2 0 -21.3 0 -21 -21.3 02/06/2005 14:40:00 14.1 1.5 19.1 10.7 13.8 1.5 18.3 10.3 0.4 0 0.4 0.4 25 5 24 305 2 0 2 0 -21.3 0 -21 -21.3 02/06/2005 14:50:00 13.4 1.1 16.1 10.7 13.1 1.1 15.6 9.9 0.4 0 0.4 0.4 27 5 28 305 2 0 2 0 -21.2 0 -21 -21.3 02/06/2005 15:00:00 14.2 1.3 16.4 11.5 13.9 1.3 16.4 10.7 0.4 0 0.4 0.4 24 5 24 305 3 0 3 0 -21.1 0 -21 -21.3 02/06/2005 15:10:00 13.9 1.3 16.1 9.9 13.6 1.5 16.4 9.5 0.4 0 0.4 0.4 28 5 29 305 3 0 3 0 -21.2 0 -21 -21.3 02/06/2005 15:20:00 14.1 1 17.2 11.1 13.6 1 16.4 11.1 0.4 0 0.4 0.4 28 5 27 305 3 0 3 0 -21.2 0 -21 -21.3 02/06/2005 15:30:00 14.4 1.6 17.9 9.5 14 1.7 17.9 9.5 0.4 0 0.4 0.4 25 5 27 305 3 0 2 0 -21.2 0 -20.8 -21.3 02/06/2005 15:40:00 14.1 1.2 16.1 9.9 13.7 1.3 16.1 9.5 0.4 0 0.4 0.4 27 5 27 305 3 0 3 0 -21.2 0 -20.8 -21.3 02/06/2005 15:50:00 14.5 1.1 17.2 11.5 14.3 1.1 17.6 10.7 0.4 0 0.4 0.4 24 4 24 305 3 0 3 0 -21.3 0 -21 -21.3 02/06/2005 16:00:00 12.9 1.4 16.4 9.9 12.7 1.3 15.6 9.5 0.4 0 0.4 0.4 23 5 30 305 3 0 3 0 -21.3 0 -21 -21.5 02/06/2005 16:10:00 13.5 1.2 16.4 9.9 13.3 1.2 16.1 10.7 0.4 0 0.4 0.4 22 5 26 305 3 0 2 0 -21.3 0 -21.1 -21.5 02/06/2005 16:20:00 15 1.2 17.2 10.7 14.8 1.2 17.6 10.7 0.4 0 0.4 0.4 19 4 13 305 3 0 2 0 -21.5 0 -21.3 -21.7 02/06/2005 16:30:00 14.9 1 16.8 12.2 14.7 1 16.8 11.8 0.4 0 0.4 0.4 20 4 18 305 3 0 2 0 -21.5 0 -21.3 -21.7 02/06/2005 16:40:00 13.7 1.5 16.4 10.3 13.4 1.5 16.8 9.5 0.4 0 0.4 0.4 24 5 23 305 2 0 2 0 -21.6 0 -21.3 -21.8 02/06/2005 16:50:00 13.3 1.3 16.4 9.9 13.1 1.3 16.4 9.9 0.4 0 0.4 0.4 22 4 21 305 2 0 2 0 -21.6 0 -21.3 -21.8 02/06/2005 17:00:00 13.5 1.2 16.1 9.9 13.3 1.2 16.4 10.3 0.4 0 0.4 0.4 23 5 19 305 2 0 2 0 -21.7 0.1 -21.3 -21.8 02/06/2005 17:10:00 14 1.2 16.1 9.5 13.8 1.2 16.1 9.9 0.4 0 0.4 0.4 24 5 25 305 2 0 2 0 -21.8 0 -21.7 -22 02/06/2005 17:20:00 13.4 1.3 16.8 9.1 13.1 1.3 16.4 9.1 0.4 0 0.4 0.4 26 5 24 305 2 0 2 0 -21.9 0 -21.8 -22 02/06/2005 17:30:00 13.4 1.2 15.6 9.9 13.2 1.2 16.4 9.1 0.4 0 0.4 0.4 20 5 17 305 2 0 2 0 -21.7 0 -21.5 -21.8 02/06/2005 17:40:00 13.3 1.2 15.6 9.9 13 1.2 16.1 10.3 0.4 0 0.4 0.4 24 5 23 305 2 0 2 0 -21.8 0 -21.7 -22 02/06/2005 17:50:00 13.7 1.1 16.8 10.3 13.5 1.1 16.4 10.7 0.4 0 0.4 0.4 20 5 18 305 2 0 2 0 -22 0 -21.8 -22.2 02/06/2005 18:00:00 14.1 1.1 16.4 11.5 14 1.1 16.8 11.1 0.4 0 0.4 0.4 19 5 16 305 2 0 2 0 -22.3 0 -22 -22.5 02/06/2005 18:10:00 14.4 1 16.8 11.5 14.2 1.1 16.8 10.7 0.4 0 0.4 0.4 18 5 20 305 2 0 2 0 -22.4 0 -22.2 -22.5 02/06/2005 18:20:00 14 1.3 17.2 11.5 13.7 1.2 16.4 10.7 0.4 0 0.4 0.4 23 5 28 305 2 0 2 0 -22.5 0 -22.4 -22.7 02/06/2005 18:30:00 14.4 1.3 17.2 10.7 14.1 1.3 17.2 11.1 0.4 0 0.4 0.4 24 5 17 305 2 0 2 0 -22.6 0 -22.5 -22.7 02/06/2005 18:40:00 13.5 1.2 16.1 9.9 13 1.3 16.8 9.9 0.4 0 0.4 0.4 24 6 19 305 2 0 2 0 -22.6 0.1 -22.5 -22.7 02/06/2005 18:50:00 15.7 1.2 17.9 12.2 15.4 1.2 18.3 12.6 0.4 0 0.4 0.4 20 4 18 305 2 0 2 0 -22.8 0 -22.5 -22.9 02/06/2005 19:00:00 14 1.3 17.2 10.7 13.7 1.3 16.8 9.9 0.4 0 0.4 0.4 21 5 18 305 2 0 1 0 -22.7 0 -22.5 -22.9 02/06/2005 19:10:00 13.4 1.4 17.2 9.9 13.2 1.4 16.8 9.9 0.4 0 0.4 0.4 18 6 19 305 2 0 2 0 -22.8 0 -22.4 -23 02/06/2005 19:20:00 14 1.2 17.2 9.9 13.8 1.3 16.4 9.1 0.4 0 0.4 0.4 13 5 17 305 2 0 2 0 -23 0 -22.7 -23.2 02/06/2005 19:30:00 13.3 1 16.1 11.1 13 1.1 15.6 10.3 0.4 0 0.4 0.4 13 4 9 305 1 0 1 0 -23.1 0 -22.9 -23.2 02/06/2005 19:40:00 13.3 1.4 16.1 9.1 13.1 1.4 16.1 9.9 0.4 0 0.4 0.4 15 5 10 305 1 0 2 0 -23 0 -22.9 -23.2 02/06/2005 19:50:00 13.4 1.2 16.4 10.3 13.1 1.3 16.8 9.9 0.4 0 0.4 0.4 16 5 13 305 1 0 1 0 -23.1 0 -23 -23.2 02/06/2005 20:00:00 13.1 1.1 15.3 9.9 12.9 1.1 15.6 9.5 0.4 0 0.4 0.4 16 5 22 305 1 0 1 0 -23 0.1 -22.5 -23.2 02/06/2005 20:10:00 13.3 1.2 15.6 9.1 13 1.2 15.6 9.5 0.4 0 0.4 0.4 14 5 15 305 1 0 1 0 -23.1 0 -22.5 -23.2 02/06/2005 20:20:00 12.4 1.1 14.9 9.5 12.3 1 15.3 9.9 0.4 0 0.4 0.4 14 5 17 305 1 0 1 0 -23.1 0.1 -22.5 -23.2 02/06/2005 20:30:00 12.8 1.2 16.1 8.8 12.6 1.2 15.6 9.5 0.4 0 0.4 0.4 12 5 12 305 1 0 1 0 -23.1 0 -22.5 -23.2 02/06/2005 20:40:00 13.5 1 16.1 11.1 13.2 1 16.1 10.3 0.4 0 0.4 0.4 13 4 19 305 1 0 1 0 -23.3 0.1 -22.7 -23.4 02/06/2005 20:50:00 13.9 1 16.1 11.1 13.6 1.1 16.4 10.3 0.4 0 0.4 0.4 11 5 0 305 1 0 2 0 -23.3 0.1 -22.7 -23.4 02/06/2005 21:00:00 13.1 1.3 15.6 9.1 12.9 1.2 15.6 9.5 0.4 0 0.4 0.4 12 4 12 305 1 0 1 0 -23.3 0 -22.7 -23.4 02/06/2005 21:10:00 13.7 1.1 16.1 10.3 13.5 1.1 16.1 10.7 0.4 0 0.4 0.4 11 4 15 305 1 0 1 0 -23.4 0 -22.7 -23.6 02/06/2005 21:20:00 13.3 1.5 16.4 9.9 13 1.4 17.6 9.9 0.4 0 0.4 0.4 14 4 13 305 1 0 1 0 -23.4 0 -23.4 -23.6 02/06/2005 21:30:00 13.1 1.3 16.1 9.9 12.8 1.5 16.1 9.5 0.4 0 0.4 0.4 18 6 8 305 1 0 1 0 -23.4 0 -23.2 -23.6 02/06/2005 21:40:00 13.2 1.1 15.6 10.3 13.1 1 15.3 10.7 0.4 0 0.4 0.4 18 5 8 305 1 0 1 0 -23.5 0 -23.2 -23.7 02/06/2005 21:50:00 14 1.3 16.8 9.9 13.6 1.3 16.4 10.3 0.4 0 0.4 0.4 15 4 15 305 1 0 1 0 -23.4 0 -23.2 -23.4 02/06/2005 22:00:00 13.3 1.1 16.1 10.7 13 1.2 15.6 10.3 0.4 0 0.4 0.4 12 4 12 305 1 0 1 0 -23.3 0.1 -22.5 -23.4 02/06/2005 22:10:00 13.1 1 16.1 10.7 13 1 16.4 10.3 0.4 0 0.4 0.4 15 5 17 305 1 0 2 0 -23.1 0.1 -22.5 -23.2 02/06/2005 22:20:00 12.9 1 15.3 10.3 12.7 1 14.9 10.3 0.4 0 0.4 0.4 21 5 19 305 1 0 1 0 -22.9 0 -22.7 -23.2 02/06/2005 22:30:00 13.7 1.1 16.1 10.7 13.5 1.1 16.1 10.7 0.4 0 0.4 0.4 16 4 11 305 1 0 1 0 -22.8 0.1 -22.5 -22.9 02/06/2005 22:40:00 14 1.1 16.4 10.7 13.9 1.2 16.4 10.7 0.4 0 0.4 0.4 16 5 21 305 2 0 2 0 -22.8 0 -22.5 -23 02/06/2005 22:50:00 13.2 1 15.6 10.3 12.9 1.2 15.6 9.9 0.4 0 0.4 0.4 17 5 12 305 1 0 1 0 -23 0 -22.9 -23.2 02/06/2005 23:00:00 13.2 1 15.6 10.7 13 1 15.3 9.9 0.4 0 0.4 0.4 18 4 12 305 1 0 1 0 -23 0 -22.7 -23.2 02/06/2005 23:10:00 13.8 1.1 16.4 11.1 13.6 1.2 16.1 10.7 0.4 0 0.4 0.4 14 5 14 305 1 0 2 0 -23.3 0.1 -22.9 -23.4 02/06/2005 23:20:00 14.7 1.1 16.8 11.8 14.6 1.2 16.8 10.3 0.4 0 0.4 0.4 12 4 6 305 1 0 1 0 -23.3 0 -22.9 -23.4 02/06/2005 23:30:00 14 1.5 16.8 10.7 13.9 1.5 16.8 10.7 0.4 0 0.4 0.4 15 4 18 305 1 0 1 0 -23.3 0 -23 -23.4 02/06/2005 23:40:00 14.1 1.1 16.4 10.7 13.8 1.2 16.4 10.7 0.4 0 0.4 0.4 15 5 9 305 1 0 1 0 -23.2 0 -22.7 -23.4 02/06/2005 23:50:00 13.7 1.2 16.4 10.7 13.5 1.3 16.4 9.9 0.4 0 0.4 0.4 13 5 4 305 1 0 1 0 -23.3 0 -23.2 -23.4 02/07/2005 00:00:00 12.8 1.5 16.4 9.1 12.4 1.5 16.1 8.8 0.4 0 0.4 0.4 16 5 14 305 1 0 1 0 -23.3 0 -22.9 -23.4 02/07/2005 00:10:00 13.2 1.3 16.1 9.5 13 1.2 15.6 9.1 0.4 0 0.4 0.4 14 5 8 305 1 0 1 0 -23.4 0 -22.9 -23.4 02/07/2005 00:20:00 13.4 1.2 16.1 10.7 13.2 1.2 15.6 10.3 0.4 0 0.4 0.4 14 5 15 305 1 0 1 0 -23.4 0 -22.9 -23.4 02/07/2005 00:30:00 13 1.3 15.6 9.5 12.9 1.3 16.1 9.5 0.4 0 0.4 0.4 13 4 8 305 1 0 1 0 -23.4 0 -22.9 -23.6 02/07/2005 00:40:00 13.4 1.1 16.1 10.7 13.3 1.1 15.6 10.7 0.4 0 0.4 0.4 11 4 13 305 1 0 1 0 -23.5 0 -22.9 -23.6 02/07/2005 00:50:00 13 1 15.6 10.7 12.8 1 15.6 10.3 0.4 0 0.4 0.4 13 5 11 305 1 0 1 0 -23.4 0.1 -22.5 -23.6 02/07/2005 01:00:00 13.9 1.3 16.4 9.9 13.7 1.4 16.8 9.9 0.4 0 0.4 0.4 15 5 9 305 1 0 1 0 -23.1 0 -22.5 -23.2 02/07/2005 01:10:00 14.6 1.1 16.8 11.5 14.5 1.2 17.2 10.7 0.4 0 0.4 0.4 13 4 13 305 1 0 1 0 -23 0.1 -22.4 -23.2 02/07/2005 01:20:00 14.8 1.1 16.8 11.8 14.7 1.2 16.8 10.7 0.4 0 0.4 0.4 13 4 15 305 1 0 1 0 -23 0.1 -22.5 -23.2 02/07/2005 01:30:00 13.9 1.3 16.8 11.1 13.7 1.3 16.4 10.3 0.4 0 0.4 0.4 14 4 12 305 1 0 1 0 -23 0 -22.5 -23.2 02/07/2005 01:40:00 14.4 1.2 16.4 10.3 14.2 1.2 16.4 9.5 0.4 0 0.4 0.4 15 5 12 305 1 0 1 0 -22.9 0 -22.5 -23 02/07/2005 01:50:00 13.7 1.5 17.2 10.3 13.5 1.7 16.8 9.5 0.4 0 0.4 0.4 18 6 26 305 1 0 1 0 -22.8 0 -22.4 -23 02/07/2005 02:00:00 14.5 1.2 16.8 11.1 14.3 1.2 16.8 11.1 0.4 0 0.4 0.4 15 4 10 305 1 0 1 0 -22.9 0 -22.5 -23 02/07/2005 02:10:00 14.7 1.1 17.2 11.5 14.7 1.2 17.2 10.3 0.4 0 0.4 0.4 16 3 13 305 1 0 1 0 -23 0.1 -22.5 -23.2 02/07/2005 02:20:00 13.8 1.2 16.4 9.9 13.5 1.3 16.8 9.1 0.4 0 0.4 0.4 17 4 15 305 1 0 1 0 -23.1 0 -22.7 -23.2 02/07/2005 02:30:00 13.2 1.3 16.1 9.9 13 1.3 15.3 9.5 0.4 0 0.4 0.4 17 5 20 305 1 0 1 0 -23.1 0 -22.7 -23.2 02/07/2005 02:40:00 12.9 1.1 16.1 10.3 12.9 1.2 16.1 9.9 0.4 0 0.4 0.4 16 5 13 305 1 0 1 0 -23.2 0 -22.5 -23.2 02/07/2005 02:50:00 12.6 1.2 15.3 9.1 12.5 1.3 15.3 8.4 0.4 0 0.4 0.4 15 5 9 305 1 0 1 0 -23.3 0.1 -22.7 -23.4 02/07/2005 03:00:00 12.7 1.1 14.9 8.8 12.4 1.1 15.3 9.5 0.4 0 0.4 0.4 13 4 13 305 1 0 1 0 -23.3 0 -22.7 -23.4 02/07/2005 03:10:00 12 1 14.5 9.5 11.9 1 14.5 8.8 0.4 0 0.4 0.4 16 4 18 305 1 0 1 0 -23.2 0 -23 -23.2 02/07/2005 03:20:00 11.2 1.2 15.3 8.4 11.2 1.2 15.3 8.4 0.4 0 0.4 0.4 16 4 14 305 1 0 1 0 -23.1 0 -22.9 -23.2 02/07/2005 03:30:00 12.7 1.3 15.6 9.1 12.6 1.3 15.6 9.1 0.4 0 0.4 0.4 17 4 20 305 1 0 1 0 -23 0 -22.9 -23.2 02/07/2005 03:40:00 13.7 1.2 16.1 9.9 13.5 1.2 16.1 10.7 0.4 0 0.4 0.4 15 5 13 305 1 0 1 0 -23 0.1 -22.9 -23.2 02/07/2005 03:50:00 13.6 1.3 17.2 9.5 13.4 1.3 16.1 9.5 0.4 0 0.4 0.4 15 4 19 305 1 0 1 0 -23 0 -22.9 -23.2 02/07/2005 04:00:00 13.2 1.2 15.6 9.9 13.1 1.1 15.6 9.9 0.4 0 0.4 0.4 15 4 19 305 1 0 1 0 -23 0.1 -22.5 -23.2 02/07/2005 04:10:00 13.1 1.5 17.2 9.5 12.9 1.5 17.2 9.1 0.4 0 0.4 0.4 17 5 16 305 1 0 1 0 -23 0 -22.5 -23.2 02/07/2005 04:20:00 12.4 1.2 14.9 9.1 12.3 1.1 14.9 8.8 0.4 0 0.4 0.4 19 5 31 305 1 0 2 0 -22.9 0 -22.5 -23.2 02/07/2005 04:30:00 13.3 1.2 16.1 10.7 13.2 1.1 16.1 10.3 0.4 0 0.4 0.4 23 5 28 305 1 0 1 0 -22.9 0 -22.5 -23 02/07/2005 04:40:00 13.4 1.4 16.4 9.9 13.2 1.4 16.4 8.8 0.4 0 0.4 0.4 21 5 22 305 1 0 1 0 -22.9 0 -22.5 -23 02/07/2005 04:50:00 12.8 1.2 15.6 9.5 12.6 1.2 16.4 8.8 0.4 0 0.4 0.4 19 5 14 305 1 0 1 0 -23 0.1 -22.5 -23.2 02/07/2005 05:00:00 13.9 1.3 17.2 9.9 13.7 1.3 16.8 9.5 0.4 0 0.4 0.4 19 4 17 305 1 0 2 0 -23.1 0 -22.9 -23.2 02/07/2005 05:10:00 12.7 1.4 16.1 8.8 12.7 1.4 16.1 9.1 0.4 0 0.4 0.4 19 5 25 305 1 0 1 0 -23 0.1 -22.7 -23.2 02/07/2005 05:20:00 13.4 1.2 16.4 9.9 13.2 1.2 15.6 9.5 0.4 0 0.4 0.4 18 5 18 305 1 0 1 0 -23 0 -22.5 -23.2 02/07/2005 05:30:00 12.9 1.2 16.1 9.9 12.7 1.2 16.8 9.9 0.4 0 0.4 0.4 19 5 15 305 1 0 1 0 -23.1 0 -22.9 -23.2 02/07/2005 05:40:00 12.7 1.3 15.3 8.8 12.5 1.3 15.3 8.8 0.4 0 0.4 0.4 16 4 13 305 1 0 1 0 -23 0 -22.9 -23.2 02/07/2005 05:50:00 12.9 1.3 15.6 8.8 12.7 1.2 15.6 8.8 0.4 0 0.4 0.4 16 4 16 305 1 0 1 0 -23.1 0 -22.9 -23.2 02/07/2005 06:00:00 12.1 1.1 14.9 9.5 11.9 1.2 14.9 9.1 0.4 0 0.4 0.4 13 5 12 305 1 0 1 0 -23.1 0 -22.9 -23.2 02/07/2005 06:10:00 13.4 1.2 16.4 11.1 13 1.3 15.6 10.3 0.4 0 0.4 0.4 12 4 13 305 1 0 1 0 -23 0 -22.7 -23.2 02/07/2005 06:20:00 13.2 1.1 15.6 9.9 13.1 1.2 15.6 9.9 0.4 0 0.4 0.4 12 4 11 305 1 0 1 0 -23 0 -22.5 -23.2 02/07/2005 06:30:00 13.8 1.1 16.1 11.1 13.6 1 16.1 11.5 0.4 0 0.4 0.4 13 4 15 305 1 0 1 0 -22.9 0 -22.9 -23 02/07/2005 06:40:00 12.9 1.2 15.6 9.9 12.7 1.2 16.1 9.9 0.4 0 0.4 0.4 14 5 15 305 1 0 1 0 -22.9 0 -22.7 -23 02/07/2005 06:50:00 13.4 1.3 16.4 9.9 13.2 1.3 16.1 9.9 0.4 0 0.4 0.4 14 4 14 305 1 0 1 0 -22.9 0 -22.9 -23 02/07/2005 07:00:00 13.3 1.3 16.1 9.9 13.1 1.3 16.1 9.9 0.4 0 0.4 0.4 13 5 10 305 1 0 1 0 -22.9 0 -22.7 -23 02/07/2005 07:10:00 13.1 1.4 16.1 9.1 12.7 1.5 15.6 8.8 0.4 0 0.4 0.4 13 4 13 305 1 0 2 0 -22.9 0 -22.7 -22.9 02/07/2005 07:20:00 12.8 1.1 16.1 9.9 12.6 1.1 15.6 9.9 0.4 0 0.4 0.4 13 4 10 305 1 0 1 0 -22.7 0 -22.5 -22.9 02/07/2005 07:30:00 13.7 1.2 16.4 10.7 13.4 1.2 16.1 10.7 0.4 0 0.4 0.4 13 4 14 305 1 0 1 0 -22.6 0 -22.5 -22.7 02/07/2005 07:40:00 13.5 1.4 16.4 10.3 13.2 1.3 16.8 10.3 0.4 0 0.4 0.4 14 4 11 305 2 0 1 0 -22.6 0 -22.5 -22.7 02/07/2005 07:50:00 13.9 1.3 16.8 10.3 13.9 1.5 16.8 9.9 0.4 0 0.4 0.4 14 4 20 305 2 0 2 0 -22.6 0 -22.5 -22.7 02/07/2005 08:00:00 13.8 1.2 16.1 9.5 13.6 1.3 16.1 9.9 0.4 0 0.4 0.4 11 4 8 305 2 0 1 0 -22.6 0.1 -22 -22.9 02/07/2005 08:10:00 13.9 1 16.4 11.5 13.7 1.2 16.4 10.7 0.4 0 0.4 0.4 12 4 12 305 1 0 1 0 -22.7 0.1 -22.2 -22.9 02/07/2005 08:20:00 14.5 1.3 17.6 11.5 14.2 1.3 16.8 10.7 0.4 0 0.4 0.4 12 4 10 305 2 0 2 0 -22.6 0.1 -22 -22.7 02/07/2005 08:30:00 13.6 1.2 16.8 10.7 13.4 1.2 17.2 10.7 0.4 0 0.4 0.4 12 5 10 305 2 0 1 0 -22.6 0 -22.2 -22.7 02/07/2005 08:40:00 14.7 1.4 17.6 10.3 14.4 1.4 17.6 10.3 0.4 0 0.4 0.4 12 5 14 305 1 0 1 0 -22.7 0 -22.2 -22.9 02/07/2005 08:50:00 14.1 1.3 18.3 9.9 13.9 1.4 17.2 10.7 0.4 0 0.4 0.4 11 5 13 305 1 0 1 0 -22.7 0 -22.4 -22.9 02/07/2005 09:00:00 14.1 1.2 16.8 9.9 13.9 1.3 17.2 9.5 0.4 0 0.4 0.4 13 5 15 305 1 0 2 0 -22.7 0 -22.5 -22.9 02/07/2005 09:10:00 14.9 1.6 17.9 10.3 14.6 1.5 18.7 10.7 0.4 0 0.4 0.4 13 5 13 305 1 0 1 0 -22.7 0 -22.2 -22.9 02/07/2005 09:20:00 15.1 1.3 17.6 11.5 15 1.5 17.6 11.5 0.4 0 0.4 0.4 12 4 13 305 1 0 1 0 -22.7 0 -22.5 -22.9 02/07/2005 09:30:00 13.8 1.3 16.8 9.9 13.6 1.3 16.8 10.3 0.4 0 0.4 0.4 10 5 12 305 1 0 1 0 -22.7 0 -22.5 -22.9 02/07/2005 09:40:00 13.3 1.3 16.8 10.3 13.1 1.4 16.8 9.9 0.4 0 0.4 0.4 11 5 13 305 1 0 1 0 -22.8 0 -22.5 -23 02/07/2005 09:50:00 14.8 1.7 18.7 10.3 14.6 1.7 18.3 10.3 0.4 0 0.4 0.4 13 5 7 305 1 0 1 0 -22.9 0 -22.7 -23 02/07/2005 10:00:00 15.1 1.6 19.1 11.1 14.9 1.5 19.1 11.5 0.4 0 0.4 0.4 9 5 6 305 1 0 1 0 -22.9 0 -22.5 -23 02/07/2005 10:10:00 15.5 1.7 18.7 10.7 15.2 1.7 18.3 10.3 0.4 0 0.4 0.4 11 6 12 305 1 0 1 0 -23 0 -22.5 -23.2 02/07/2005 10:20:00 15.1 1.5 18.3 11.5 14.9 1.4 18.3 11.5 0.4 0 0.4 0.4 13 5 11 305 1 0 1 0 -23.1 0.1 -22.5 -23.4 02/07/2005 10:30:00 15.5 1.5 18.7 12.2 15.2 1.4 18.3 11.8 0.4 0 0.4 0.4 12 5 11 305 1 0 1 0 -23.2 0 -22.7 -23.2 02/07/2005 10:40:00 15.5 1.2 18.3 11.8 15.4 1.3 18.3 11.1 0.4 0 0.4 0.4 13 5 23 305 1 0 1 0 -23.2 0 -22.7 -23.4 02/07/2005 10:50:00 14.5 1.7 18.3 10.3 14.2 1.7 18.7 10.3 0.4 0 0.4 0.4 13 5 7 305 1 0 1 0 -23.3 0 -22.9 -23.4 02/07/2005 11:00:00 15.8 1.2 17.9 11.5 15.3 1.3 18.3 11.1 0.4 0 0.4 0.4 10 4 11 305 1 0 1 0 -23.4 0 -23 -23.6 02/07/2005 11:10:00 14.2 1.6 17.9 10.7 13.9 1.7 17.6 9.5 0.4 0 0.4 0.4 12 5 5 305 1 0 1 0 -23.4 0 -23.2 -23.6 02/07/2005 11:20:00 15.1 1.5 18.3 10.7 14.8 1.7 17.9 9.9 0.4 0 0.4 0.4 14 4 13 305 1 0 1 0 -23.5 0 -23.4 -23.7 02/07/2005 11:30:00 14.7 1.5 17.9 11.5 14.3 1.4 17.6 11.1 0.4 0 0.4 0.4 14 4 8 305 1 0 1 0 -23.4 0 -22.9 -23.6 02/07/2005 11:40:00 14.8 1.5 17.9 10.7 14.5 1.6 18.3 10.3 0.4 0 0.4 0.4 12 5 9 305 1 0 1 0 -23.4 0 -23 -23.6 02/07/2005 11:50:00 15.2 1.4 18.7 11.8 14.9 1.5 19.1 11.5 0.4 0 0.4 0.4 12 4 13 305 1 0 1 0 -23.4 0 -23.2 -23.6 02/07/2005 12:00:00 15.1 1.4 18.3 11.8 14.8 1.5 17.9 10.7 0.4 0 0.4 0.4 13 5 12 305 1 0 1 0 -23.4 0 -22.9 -23.6 02/07/2005 12:10:00 14.2 1.5 17.9 10.7 14 1.4 17.6 10.7 0.4 0 0.4 0.4 14 5 13 305 1 0 1 0 -23.4 0 -23.2 -23.4 02/07/2005 12:20:00 15.3 1.3 18.7 11.1 15 1.3 18.3 11.5 0.4 0 0.4 0.4 13 5 9 305 1 0 1 0 -23.3 0 -23.2 -23.4 02/07/2005 12:30:00 14.9 1.6 17.9 9.5 14.6 1.6 17.9 10.7 0.4 0 0.4 0.4 13 5 10 305 2 0 2 0 -23.3 0 -23.2 -23.4 02/07/2005 12:40:00 15.2 1.5 19.1 11.1 15 1.5 19.5 11.5 0.4 0 0.4 0.4 12 5 2 305 2 0 1 0 -23.1 0 -22.7 -23.2 02/07/2005 12:50:00 14.8 1.5 17.9 11.1 14.5 1.5 17.9 10.7 0.4 0 0.4 0.4 7 5 5 305 2 0 2 0 -23 0 -22.9 -23.2 02/07/2005 13:00:00 15.3 1.5 18.7 11.8 15.2 1.5 18.7 11.5 0.4 0 0.4 0.4 5 5 10 305 2 0 1 0 -22.9 0 -22.7 -23 02/07/2005 13:10:00 16.5 1.5 20.2 12.6 16.3 1.5 20.2 12.2 0.4 0 0.4 0.4 7 5 7 305 2 0 2 0 -22.7 0.1 -22.5 -22.9 02/07/2005 13:20:00 15.7 1.6 20.2 11.8 15.6 1.7 20.2 11.5 0.4 0 0.4 0.4 6 6 12 305 2 0 2 0 -22.3 0.1 -22 -22.5 02/07/2005 13:30:00 16.1 1.6 19.9 11.5 15.9 1.6 20.2 11.8 0.4 0 0.4 0.4 359 4 0 305 2 0 2 0 -22.6 0.2 -22.2 -22.9 02/07/2005 13:40:00 16 1.5 21 11.8 15.8 1.6 20.6 12.2 0.4 0 0.4 0.4 3 6 4 305 2 0 2 0 -22.7 0.1 -22.5 -23 02/07/2005 13:50:00 15.6 1.7 19.5 11.5 15.5 1.7 19.9 11.1 0.4 0 0.4 0.4 7 6 16 305 2 0 2 0 -22.7 0.1 -22.4 -22.9 02/07/2005 14:00:00 15.1 1.9 19.5 11.1 15 2 19.1 10.3 0.4 0 0.4 0.4 8 6 7 305 2 0 2 0 -22.7 0.1 -22.4 -22.9 02/07/2005 14:10:00 15.9 1.7 19.5 11.1 15.8 1.7 19.1 11.1 0.4 0 0.4 0.4 7 5 5 305 2 0 2 0 -22.8 0 -22.5 -22.9 02/07/2005 14:20:00 16.5 1.5 19.5 11.8 16.3 1.6 19.5 11.5 0.4 0 0.4 0.4 2 5 1 305 2 0 2 0 -22.9 0.1 -22.5 -23.2 02/07/2005 14:30:00 16.7 1.4 20.2 12.2 16.4 1.3 19.5 12.2 0.4 0 0.4 0.4 4 5 8 305 2 0 2 0 -23.1 0 -22.9 -23.2 02/07/2005 14:40:00 16.2 1.5 19.1 12.2 16.1 1.4 19.5 12.2 0.4 0 0.4 0.4 8 5 7 305 2 0 2 0 -23.1 0 -22.5 -23.2 02/07/2005 14:50:00 15.1 1.5 18.3 10.7 15 1.5 18.7 10.7 0.4 0 0.4 0.4 5 5 4 305 2 0 2 0 -22.9 0 -22.9 -23.2 02/07/2005 15:00:00 15.6 1.5 18.3 11.8 15.5 1.6 19.1 11.8 0.4 0 0.4 0.4 6 6 2 305 2 0 2 0 -23.2 0.1 -22.5 -23.4 02/07/2005 15:10:00 15.5 1.5 19.9 11.1 15.6 1.5 19.5 11.1 0.4 0 0.4 0.4 3 5 4 305 2 0 2 0 -23.3 0.1 -23 -23.6 02/07/2005 15:20:00 15.5 1.3 18.7 10.3 15.3 1.3 17.9 11.1 0.4 0 0.4 0.4 7 5 3 305 2 0 2 0 -23.2 0.1 -22.9 -23.4 02/07/2005 15:30:00 16 1.6 19.5 11.1 15.9 1.6 19.9 10.7 0.4 0 0.4 0.4 2 4 1 305 2 0 2 0 -23.3 0.1 -23 -23.6 02/07/2005 15:40:00 15.6 1.7 19.1 11.1 15.4 1.7 19.1 10.7 0.4 0 0.4 0.4 5 5 6 305 2 0 2 0 -23.4 0 -23.2 -23.6 02/07/2005 15:50:00 15 1.2 17.6 11.1 14.8 1.2 17.2 11.5 0.4 0 0.4 0.4 1 5 2 305 2 0 2 0 -23.5 0 -23.2 -23.6 02/07/2005 16:00:00 15.1 1.5 18.3 11.1 14.9 1.5 19.1 11.1 0.4 0 0.4 0.4 9 5 11 305 2 0 2 0 -23.6 0.1 -22.9 -23.9 02/07/2005 16:10:00 13.4 1.6 16.8 10.3 13.2 1.5 16.8 9.1 0.4 0 0.4 0.4 9 7 8 305 2 0 2 0 -23.6 0.1 -23.4 -23.9 02/07/2005 16:20:00 15.5 1.4 18.3 11.8 15.3 1.3 18.3 11.8 0.4 0 0.4 0.4 10 4 10 305 2 0 2 0 -23.9 0 -23.7 -23.9 02/07/2005 16:30:00 15.5 1.6 18.3 11.1 15.2 1.6 17.9 9.9 0.4 0 0.4 0.4 10 4 10 305 1 0 2 0 -23.9 0.1 -23.7 -24.1 02/07/2005 16:40:00 15.1 1.5 18.3 10.7 14.7 1.5 18.3 10.3 0.4 0 0.4 0.4 9 4 9 305 1 0 1 0 -24.1 0.1 -23.9 -24.2 02/07/2005 16:50:00 15.3 1.5 18.3 11.8 15 1.5 18.3 11.5 0.4 0 0.4 0.4 7 6 358 305 1 0 1 0 -24.3 0.1 -23.6 -24.6 02/07/2005 17:00:00 15.5 1.5 18.3 10.7 15.1 1.5 18.3 11.1 0.4 0 0.4 0.4 4 6 8 305 1 0 1 0 -24.4 0.1 -23.7 -24.6 02/07/2005 17:10:00 15.9 1.5 18.7 11.8 15.4 1.3 18.7 11.8 0.4 0 0.4 0.4 7 4 9 305 1 0 1 0 -24.7 0.1 -24.1 -24.9 02/07/2005 17:20:00 14.7 1.3 17.9 11.5 14.3 1.4 18.3 10.7 0.4 0 0.4 0.4 6 5 6 305 1 0 1 0 -24.6 0 -24.6 -24.9 02/07/2005 17:30:00 14.8 1.5 18.3 11.5 14.5 1.5 18.3 10.7 0.4 0 0.4 0.4 7 5 2 305 1 0 1 0 -24.5 0 -24.2 -24.6 02/07/2005 17:40:00 15.3 1.5 18.3 10.7 15.1 1.3 17.9 11.5 0.4 0 0.4 0.4 6 5 10 305 1 0 1 0 -24.6 0.1 -24.1 -24.7 02/07/2005 17:50:00 14.9 1.6 17.9 11.1 14.6 1.7 17.9 10.7 0.4 0 0.4 0.4 4 6 359 305 1 0 1 0 -24.7 0.1 -24.6 -24.9 02/07/2005 18:00:00 14.7 1.6 18.3 10.3 14.4 1.4 19.1 9.9 0.4 0 0.4 0.4 5 5 1 305 1 0 1 0 -24.8 0.1 -24.2 -25.1 02/07/2005 18:10:00 14.4 1.3 17.9 10.7 14.3 1.2 17.2 10.7 0.4 0 0.4 0.4 6 6 357 305 1 0 1 0 -24.9 0.1 -24.2 -25.1 02/07/2005 18:20:00 15.7 1.4 18.7 11.5 15.3 1.4 18.3 11.1 0.4 0 0.4 0.4 4 5 1 305 1 0 1 0 -24.9 0.1 -24.4 -25.1 02/07/2005 18:30:00 15.8 1.4 18.3 12.2 15.6 1.2 18.7 12.2 0.4 0 0.4 0.4 2 5 350 305 1 0 1 0 -24.9 0.1 -24.4 -25.1 02/07/2005 18:40:00 14.4 1.6 17.9 11.1 14 1.5 17.9 10.3 0.4 0 0.4 0.4 5 5 10 305 1 0 1 0 -24.8 0.1 -24.2 -25.1 02/07/2005 18:50:00 14.9 1.4 17.9 11.1 14.5 1.3 17.6 11.1 0.4 0 0.4 0.4 2 5 354 305 1 0 1 0 -24.9 0.1 -24.4 -25.1 02/07/2005 19:00:00 14.7 1.5 17.6 11.1 14.4 1.5 17.2 10.7 0.4 0 0.4 0.4 3 5 0 305 1 0 1 0 -25 0.1 -24.6 -25.2 02/07/2005 19:10:00 14.8 1.2 17.2 10.7 14.4 1.2 17.2 10.7 0.4 0 0.4 0.4 1 5 359 305 1 0 1 0 -25.1 0.1 -24.6 -25.2 02/07/2005 19:20:00 14.8 1.4 17.2 10.7 14.4 1.5 17.2 10.3 0.4 0 0.4 0.4 2 5 358 305 1 0 1 0 -25.1 0.1 -24.6 -25.2 02/07/2005 19:30:00 14 1.3 17.6 10.3 14 1.3 17.9 10.7 0.4 0 0.4 0.4 2 5 0 305 1 0 1 0 -25.1 0.1 -24.6 -25.2 02/07/2005 19:40:00 14.3 1.9 17.9 9.1 14 1.7 17.2 8.8 0.4 0 0.4 0.4 357 5 353 305 1 0 1 0 -25.2 0.1 -24.6 -25.4 02/07/2005 19:50:00 14.4 1.7 17.6 9.9 14.2 1.6 17.6 10.3 0.4 0 0.4 0.4 357 5 355 305 1 0 1 0 -25.3 0.1 -24.6 -25.4 02/07/2005 20:00:00 15.7 1.3 17.9 12.6 15.3 1.2 18.3 12.6 0.4 0 0.4 0.4 357 4 355 305 1 0 1 0 -25.4 0 -24.9 -25.6 02/07/2005 20:10:00 16.4 1.7 20.2 11.5 16 1.7 19.9 11.5 0.4 0 0.4 0.4 358 5 353 305 1 0 1 0 -25.2 0.1 -24.7 -25.4 02/07/2005 20:20:00 15.6 1.5 19.5 11.5 15.2 1.5 19.1 11.1 0.4 0 0.4 0.4 0 5 5 305 1 0 1 0 -25.1 0 -24.6 -25.2 02/07/2005 20:30:00 16 1.6 19.1 11.5 15.7 1.4 19.5 11.5 0.4 0 0.4 0.4 0 5 356 305 1 0 1 0 -25.1 0.1 -24.6 -25.2 02/07/2005 20:40:00 15.4 1.7 19.5 10.7 15.2 1.5 19.1 11.1 0.4 0 0.4 0.4 2 5 358 305 1 0 1 0 -25 0.1 -24.6 -25.2 02/07/2005 20:50:00 14.7 1.8 19.1 11.1 14.6 1.7 19.5 11.1 0.4 0 0.4 0.4 0 5 357 305 1 0 1 0 -24.9 0.2 -24.2 -25.1 02/07/2005 21:00:00 15.2 1.8 19.1 10.7 14.9 1.7 18.7 11.1 0.4 0 0.4 0.4 1 5 356 305 1 0 1 0 -24.8 0.1 -24.2 -25.1 02/07/2005 21:10:00 14.7 1.5 18.3 10.3 14.6 1.5 18.3 11.1 0.4 0 0.4 0.4 3 5 3 305 1 0 1 0 -24.9 0.1 -24.2 -25.1 02/07/2005 21:20:00 15.3 1.6 18.7 9.9 15 1.6 18.3 11.1 0.4 0 0.4 0.4 4 5 11 305 1 0 1 0 -25 0.1 -24.6 -25.1 02/07/2005 21:30:00 15 1.5 19.1 10.3 14.7 1.5 18.3 10.3 0.4 0 0.4 0.4 5 5 6 305 1 0 1 0 -25 0 -24.6 -25.1 02/07/2005 21:40:00 14.9 1.5 18.7 11.1 14.6 1.5 18.7 10.7 0.4 0 0.4 0.4 6 5 4 305 1 0 1 0 -24.9 0.1 -24.4 -25.1 02/07/2005 21:50:00 16.2 1.7 19.9 11.8 15.7 1.6 19.9 11.5 0.4 0 0.4 0.4 6 5 5 305 1 0 1 0 -24.6 0 -24.1 -24.7 02/07/2005 22:00:00 15.5 1.9 19.9 11.1 15.2 1.9 20.2 10.7 0.4 0 0.4 0.4 7 5 359 305 1 0 1 0 -24.4 0.1 -23.9 -24.6 02/07/2005 22:10:00 16 1.7 20.6 11.1 15.7 1.7 19.5 11.5 0.4 0 0.4 0.4 6 5 357 305 1 0 1 0 -24.4 0 -23.9 -24.6 02/07/2005 22:20:00 15.2 1.7 18.7 11.1 15.1 1.5 18.7 11.1 0.4 0 0.4 0.4 7 5 8 305 1 0 1 0 -24.3 0.2 -23.9 -24.6 02/07/2005 22:30:00 16 1.4 19.5 12.2 15.9 1.3 19.1 12.2 0.4 0 0.4 0.4 6 5 6 305 1 0 1 0 -24.2 0.1 -23.9 -24.4 02/07/2005 22:40:00 15.2 1.6 18.3 11.5 14.8 1.6 18.3 11.5 0.4 0 0.4 0.4 5 5 8 305 1 0 1 0 -24.1 0.1 -23.9 -24.4 02/07/2005 22:50:00 15.4 1.6 19.1 11.5 15.2 1.5 19.1 11.1 0.4 0 0.4 0.4 5 6 7 305 1 0 1 0 -24.1 0.1 -23.9 -24.4 02/07/2005 23:00:00 14.7 1.5 18.3 11.1 14.5 1.4 18.3 11.1 0.4 0 0.4 0.4 6 5 5 305 1 0 1 0 -23.9 0 -23.7 -24.1 02/07/2005 23:10:00 16 1.7 19.1 11.1 15.7 1.7 18.7 11.5 0.4 0 0.4 0.4 1 5 7 305 1 0 1 0 -23.8 0.1 -23.6 -23.9 02/07/2005 23:20:00 15.2 1.7 19.1 10.3 14.9 1.7 18.7 10.3 0.4 0 0.4 0.4 3 6 2 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 02/07/2005 23:30:00 15.7 1.7 19.5 11.1 15.6 1.6 19.5 11.5 0.4 0 0.4 0.4 4 7 1 305 1 0 1 0 -23.7 0.2 -23.2 -23.9 02/07/2005 23:40:00 13.8 1.4 17.2 10.3 13.7 1.4 17.2 9.9 0.4 0 0.4 0.4 4 7 359 305 1 0 1 0 -23.7 0.1 -23.4 -23.9 02/07/2005 23:50:00 15 1.9 18.3 9.5 14.8 1.7 18.7 9.5 0.4 0 0.4 0.4 0 6 0 305 1 0 1 0 -23.7 0.1 -23.4 -23.9 02/08/2005 00:00:00 15.1 1.7 19.5 9.9 14.9 1.7 19.9 9.5 0.4 0 0.4 0.4 0 6 353 305 1 0 1 0 -23.6 0 -23.4 -23.9 02/08/2005 00:10:00 15 1.7 18.3 10.7 14.9 1.7 18.7 9.9 0.4 0 0.4 0.4 1 6 7 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 02/08/2005 00:20:00 14.9 1.7 19.1 10.3 14.7 1.6 18.7 10.7 0.4 0 0.4 0.4 0 5 1 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 02/08/2005 00:30:00 15 1.5 18.3 10.3 14.8 1.5 17.9 10.7 0.4 0 0.4 0.4 2 6 355 305 1 0 1 0 -23.9 0 -23.7 -23.9 02/08/2005 00:40:00 15.7 1.2 18.7 11.8 15.5 1.3 18.7 10.7 0.4 0 0.4 0.4 3 5 356 305 1 0 1 0 -23.8 0 -23.7 -24.1 02/08/2005 00:50:00 14.4 1.3 17.9 10.7 14.3 1.3 18.7 11.1 0.4 0 0.4 0.4 4 6 13 305 1 0 1 0 -23.8 0.1 -23.4 -24.1 02/08/2005 01:00:00 15 1.6 19.1 11.1 14.7 1.5 18.3 10.7 0.4 0 0.4 0.4 4 6 356 305 1 0 1 0 -23.9 0.1 -23.4 -23.9 02/08/2005 01:10:00 15.5 1.4 18.3 11.1 15.3 1.3 18.3 11.1 0.4 0 0.4 0.4 4 6 8 305 1 0 1 0 -23.8 0.1 -23.2 -23.9 02/08/2005 01:20:00 15.2 1.4 18.3 11.1 15.1 1.4 19.1 10.7 0.4 0 0.4 0.4 359 7 348 305 1 0 1 0 -23.8 0.1 -23.2 -23.9 02/08/2005 01:30:00 15.9 1.5 19.5 11.8 15.8 1.5 19.9 12.2 0.4 0 0.4 0.4 354 5 355 305 1 0 1 0 -23.8 0.1 -23.2 -23.9 02/08/2005 01:40:00 16.4 1.6 19.5 12.2 16.2 1.7 20.2 12.2 0.4 0 0.4 0.4 357 6 350 305 1 0 1 0 -23.7 0.1 -23.2 -23.9 02/08/2005 01:50:00 16.2 1.5 20.2 12.6 16 1.5 19.9 12.2 0.4 0 0.4 0.4 357 6 356 305 1 0 1 0 -23.7 0.1 -23.2 -23.9 02/08/2005 02:00:00 17.2 1.5 20.2 12.6 17 1.6 20.2 12.6 0.4 0 0.4 0.4 358 6 1 305 1 0 1 0 -23.6 0.1 -23 -23.9 02/08/2005 02:10:00 16 1.5 19.9 11.8 15.8 1.6 19.5 11.5 0.4 0 0.4 0.4 358 5 0 305 1 0 1 0 -23.6 0.1 -22.9 -23.9 02/08/2005 02:20:00 15.5 1.3 18.3 11.8 15.3 1.3 17.9 11.8 0.4 0 0.4 0.4 354 7 358 305 1 0 1 0 -23.5 0 -22.9 -23.7 02/08/2005 02:30:00 15.7 1.5 19.5 10.7 15.5 1.7 19.5 9.5 0.4 0 0.4 0.4 355 6 357 305 1 0 1 0 -23.5 0.1 -22.9 -23.7 02/08/2005 02:40:00 15.8 1.4 19.5 11.5 15.7 1.3 19.1 11.8 0.4 0 0.4 0.4 353 6 347 305 1 0 1 0 -23.5 0.1 -23.2 -23.9 02/08/2005 02:50:00 15 1.3 17.9 11.1 14.8 1.4 17.9 11.5 0.4 0 0.4 0.4 2 5 0 305 1 0 1 0 -23.7 0.1 -23.4 -23.9 02/08/2005 03:00:00 16.5 2.3 20.2 11.1 16.3 2.3 20.6 10.7 0.4 0 0.4 0.4 358 6 356 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 02/08/2005 03:10:00 16.7 1.6 21 12.2 16.4 1.6 20.6 11.5 0.4 0 0.4 0.4 0 5 356 305 1 0 1 0 -23.8 0.1 -23.6 -23.9 02/08/2005 03:20:00 15.6 1.5 18.3 11.1 15.5 1.4 18.7 11.8 0.4 0 0.4 0.4 357 7 356 305 1 0 1 0 -23.8 0.1 -23.6 -24.1 02/08/2005 03:30:00 15.4 1.5 19.1 10.7 15.3 1.4 19.1 11.8 0.4 0 0.4 0.4 356 5 353 305 1 0 1 0 -24.1 0.1 -23.7 -24.4 02/08/2005 03:40:00 15.4 1.3 18.3 11.5 15.1 1.5 18.3 11.5 0.4 0 0.4 0.4 356 5 351 305 1 0 1 0 -24.1 0.1 -23.9 -24.4 02/08/2005 03:50:00 15.7 1.2 18.3 11.8 15.4 1.3 18.3 11.8 0.4 0 0.4 0.4 357 5 354 305 1 0 1 0 -24.1 0.1 -23.7 -24.4 02/08/2005 04:00:00 15 1.2 17.6 11.8 14.8 1.3 17.6 10.7 0.4 0 0.4 0.4 355 4 350 305 1 0 1 0 -23.9 0 -23.6 -23.9 02/08/2005 04:10:00 14 1.6 17.6 10.3 14 1.6 17.9 10.7 0.4 0 0.4 0.4 358 6 6 305 1 0 1 0 -23.9 0 -23.7 -23.9 02/08/2005 04:20:00 13.9 1.5 17.6 10.7 13.7 1.5 17.2 10.7 0.4 0 0.4 0.4 2 7 5 305 1 0 1 0 -23.9 0.1 -23.6 -24.1 02/08/2005 04:30:00 14.8 1.4 17.9 11.1 14.6 1.5 17.9 10.3 0.4 0 0.4 0.4 356 7 359 305 1 0 1 0 -23.9 0 -23.7 -23.9 02/08/2005 04:40:00 14.7 1.5 18.3 11.1 14.5 1.5 18.7 10.7 0.4 0 0.4 0.4 2 5 350 305 1 0 1 0 -24.2 0.2 -23.9 -24.6 02/08/2005 04:50:00 14.2 1.6 18.7 10.7 14.2 1.5 17.6 10.3 0.4 0 0.4 0.4 4 5 1 305 1 0 1 0 -24.4 0 -24.2 -24.6 02/08/2005 05:00:00 14.7 1.5 17.9 10.7 14.4 1.5 17.9 10.7 0.4 0 0.4 0.4 3 5 0 305 1 0 1 0 -24.4 0 -24.2 -24.6 02/08/2005 05:10:00 14.9 1.5 18.7 10.3 14.7 1.5 18.7 9.5 0.4 0 0.4 0.4 0 5 351 305 1 0 1 0 -24.5 0 -24.2 -24.6 02/08/2005 05:20:00 14.5 1.4 17.6 10.3 14.4 1.5 17.9 10.7 0.4 0 0.4 0.4 1 6 11 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 05:30:00 14.6 1.5 18.3 10.7 14.6 1.5 18.7 10.7 0.4 0 0.4 0.4 3 5 6 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 05:40:00 13.9 1.3 16.8 10.3 13.7 1.3 16.8 9.9 0.4 0 0.4 0.4 4 5 7 305 1 0 1 0 -24.5 0 -24.2 -24.6 02/08/2005 05:50:00 12.7 1.5 17.2 8.8 12.6 1.5 16.8 8.4 0.4 0 0.4 0.4 3 6 7 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 06:00:00 14.7 1.5 17.9 10.7 14.8 1.5 18.3 10.3 0.4 0 0.4 0.4 6 5 10 305 1 0 1 0 -24.5 0 -24.1 -24.6 02/08/2005 06:10:00 14.1 1.8 18.3 10.3 13.8 1.9 17.9 9.9 0.4 0 0.4 0.4 9 6 359 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 06:20:00 13.9 1.2 16.8 10.3 13.7 1.2 16.8 9.9 0.4 0 0.4 0.4 11 6 12 305 1 0 1 0 -24.4 0 -24.2 -24.6 02/08/2005 06:30:00 13.4 1.5 16.8 9.9 13.2 1.5 16.4 9.5 0.4 0 0.4 0.4 16 5 13 305 1 0 1 0 -24.5 0 -24.2 -24.6 02/08/2005 06:40:00 14.5 1.6 18.7 11.1 14.3 1.6 17.9 11.1 0.4 0 0.4 0.4 14 6 23 305 1 0 1 0 -24.5 0 -24.2 -24.6 02/08/2005 06:50:00 14.2 1.7 17.6 10.7 14 1.6 17.2 10.3 0.4 0 0.4 0.4 16 6 13 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 07:00:00 13.8 1.7 17.2 9.9 13.7 1.8 17.6 8.8 0.4 0 0.4 0.4 14 5 12 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 07:10:00 13.8 2.2 17.9 7.6 13.6 2.2 17.6 8.4 0.4 0 0.4 0.4 10 6 16 305 1 0 1 0 -24.3 0 -24.1 -24.6 02/08/2005 07:20:00 13.1 1.5 16.1 8 13 1.4 16.1 8.4 0.4 0 0.4 0.4 12 6 10 305 1 0 1 0 -24.4 0 -24.2 -24.6 02/08/2005 07:30:00 13.9 1.8 19.5 8.4 13.7 1.9 19.5 7.6 0.4 0 0.4 0.4 10 5 9 305 1 0 1 0 -24.2 0 -24.1 -24.4 02/08/2005 07:40:00 13.6 1.5 17.6 10.3 13.4 1.5 17.2 9.5 0.4 0 0.4 0.4 11 5 13 305 1 0 1 0 -24.3 0 -24.1 -24.6 02/08/2005 07:50:00 12.5 1.7 17.9 8 12.3 1.7 17.9 8.4 0.4 0 0.4 0.4 12 6 12 305 1 0 1 0 -24.6 0 -24.2 -24.7 02/08/2005 08:00:00 13.6 1.5 17.2 9.5 13.6 1.6 17.2 9.5 0.4 0 0.4 0.4 10 5 16 305 1 0 1 0 -24.5 0 -24.1 -24.6 02/08/2005 08:10:00 12.5 1.5 16.4 8.8 12.6 1.5 16.1 8.8 0.4 0 0.4 0.4 9 6 357 305 1 0 1 0 -24.6 0 -24.4 -24.7 02/08/2005 08:20:00 13.9 1.7 18.3 10.3 13.9 1.7 17.6 9.5 0.4 0 0.4 0.4 6 6 356 305 1 0 1 0 -24.6 0.1 -24.1 -24.7 02/08/2005 08:30:00 14.9 1.6 18.3 10.7 14.9 1.5 18.7 10.3 0.4 0 0.4 0.4 2 5 2 305 1 0 1 0 -24.8 0 -24.4 -24.9 02/08/2005 08:40:00 14.9 1.6 18.7 10.7 14.7 1.5 17.9 9.9 0.4 0 0.4 0.4 3 5 0 305 1 0 1 0 -25 0 -24.6 -25.2 02/08/2005 08:50:00 13.3 1.5 17.6 9.9 13.3 1.5 17.2 9.9 0.4 0 0.4 0.4 3 6 3 305 1 0 1 0 -24.9 0.1 -24.4 -25.1 02/08/2005 09:00:00 14.8 1.7 19.1 10.7 14.7 1.6 17.9 10.3 0.4 0 0.4 0.4 4 5 359 305 1 0 1 0 -24.8 0.1 -24.2 -25.1 02/08/2005 09:10:00 14.6 1.3 17.9 10.7 14.7 1.3 17.6 11.1 0.4 0 0.4 0.4 3 5 356 305 1 0 1 0 -24.9 0.1 -24.2 -25.1 02/08/2005 09:20:00 14 1.7 17.6 9.9 13.8 1.6 17.9 9.9 0.4 0 0.4 0.4 3 5 1 305 1 0 1 0 -24.9 0.1 -24.4 -25.1 02/08/2005 09:30:00 14.1 1.5 17.6 10.3 14 1.4 17.6 9.9 0.4 0 0.4 0.4 2 5 2 305 1 0 1 0 -24.9 0.1 -24.4 -25.1 02/08/2005 09:40:00 14 1.7 17.6 9.5 13.7 1.7 17.9 9.5 0.4 0 0.4 0.4 2 5 358 305 1 0 1 0 -24.8 0.1 -24.1 -25.1 02/08/2005 09:50:00 14.1 1.5 17.2 10.3 14 1.4 16.8 9.9 0.4 0 0.4 0.4 2 5 5 305 1 0 1 0 -24.7 0.1 -24.1 -24.9 02/08/2005 10:00:00 12.2 1.5 15.3 8.4 12 1.4 14.9 8 0.4 0 0.4 0.4 4 5 4 305 1 0 1 0 -24.6 0 -24.1 -24.7 02/08/2005 10:10:00 12.5 1.6 16.8 8.4 12.4 1.6 16.8 8.4 0.4 0 0.4 0.4 2 5 0 305 1 0 1 0 -24.6 0 -24.4 -24.7 02/08/2005 10:20:00 12.2 1.4 15.3 8.4 12.1 1.4 15.6 8.8 0.4 0 0.4 0.4 2 5 7 305 1 0 1 0 -24.7 0.1 -24.2 -24.7 02/08/2005 10:30:00 12 0.9 14.1 9.5 12.1 1.1 15.3 9.1 0.4 0 0.4 0.4 357 5 357 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 10:40:00 13.3 1.2 15.6 9.5 13.2 1.2 16.1 9.5 0.4 0 0.4 0.4 351 6 350 305 1 0 1 0 -24.5 0 -24.2 -24.6 02/08/2005 10:50:00 12.9 1.3 15.6 9.1 12.9 1.3 15.6 9.1 0.4 0 0.4 0.4 351 6 355 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 11:00:00 12.1 1 14.5 9.1 12 1.1 14.9 8.4 0.4 0 0.4 0.4 356 5 341 305 1 0 1 0 -24.6 0 -24.4 -24.7 02/08/2005 11:10:00 10.8 1.2 13.7 7.6 10.9 1.1 13.7 8 0.4 0 0.4 0.4 355 5 354 305 1 0 1 0 -24.6 0 -24.6 -24.6 02/08/2005 11:20:00 11.3 1.4 14.5 7.6 11.4 1.5 14.5 7.6 0.4 0 0.4 0.4 349 7 351 305 1 0 1 0 -24.5 0 -23.9 -24.6 02/08/2005 11:30:00 10.4 1.3 13.3 6.8 10.4 1.3 13 6.8 0.4 0 0.4 0.4 350 5 351 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 11:40:00 10.4 1.3 13 6.8 10.5 1.3 13.7 7.2 0.4 0 0.4 0.4 346 9 336 305 1 0 1 0 -24.4 0 -24.2 -24.6 02/08/2005 11:50:00 9.7 1 12.2 7.2 9.8 1 12.2 7.2 0.4 0 0.4 0.4 3 8 359 305 1 0 1 0 -24.6 0 -24.4 -24.7 02/08/2005 12:00:00 9.6 1.1 11.8 7.2 9.6 1 11.8 7.2 0.4 0 0.4 0.4 6 6 11 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 12:10:00 11.3 1.3 14.5 7.6 11.3 1.3 14.1 7.6 0.4 0 0.4 0.4 7 6 8 305 1 0 1 0 -24.6 0 -24.6 -24.6 02/08/2005 12:20:00 10.9 1.5 14.9 7.6 10.8 1.5 14.5 7.6 0.4 0 0.4 0.4 6 6 0 305 1 0 1 0 -24.5 0 -24.6 -24.6 02/08/2005 12:30:00 10.8 1.2 13.3 7.6 10.8 1.2 13 8 0.4 0 0.4 0.4 5 5 11 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 12:40:00 11.5 1.2 13.7 7.6 11.5 1.2 14.1 8.4 0.4 0 0.4 0.4 3 5 5 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 12:50:00 9.8 1.3 12.6 6.1 9.8 1.4 13.3 6.1 0.4 0 0.4 0.4 5 6 6 305 1 0 1 0 -24.5 0 -24.4 -24.6 02/08/2005 13:00:00 10.3 0.8 11.8 7.6 10.3 0.9 12.6 7.6 0.4 0 0.4 0.4 0 5 354 305 1 0 1 0 -24.3 0.1 -24.1 -24.6 02/08/2005 13:10:00 9.4 1 12.2 7.2 9.5 1 12.2 6.5 0.4 0 0.4 0.4 359 7 3 305 1 0 1 0 -24.1 0 -23.9 -24.2 02/08/2005 13:20:00 10 1.1 12.2 6.8 10.1 1.2 12.6 7.2 0.4 0 0.4 0.4 3 5 3 305 1 0 1 0 -24.1 0 -23.9 -24.2 02/08/2005 13:30:00 9.8 1.1 12.6 7.2 9.8 1.1 12.2 6.8 0.4 0 0.4 0.4 4 5 5 305 1 0 1 0 -24 0.1 -23.9 -24.2 02/08/2005 13:40:00 10.6 1.1 12.6 6.5 10.7 1.1 13 6.5 0.4 0 0.4 0.4 1 6 357 305 1 0 1 0 -24.1 0.1 -23.9 -24.2 02/08/2005 13:50:00 10.2 1 12.6 6.5 10.3 1 12.2 6.5 0.4 0 0.4 0.4 1 4 357 305 1 0 1 0 -24 0 -23.9 -24.2 02/08/2005 14:00:00 8.8 0.8 10.7 6.5 8.9 0.8 10.7 6.5 0.4 0 0.4 0.4 0 6 359 305 1 0 1 0 -23.9 0 -23.9 -24.1 02/08/2005 14:10:00 9.2 1 11.1 6.8 9.3 1 11.8 6.8 0.4 0 0.4 0.4 359 6 359 305 1 0 1 0 -23.8 0 -23.7 -23.9 02/08/2005 14:20:00 9.2 0.9 11.5 6.5 9.2 1 11.8 6.8 0.4 0 0.4 0.4 358 6 352 305 1 0 1 0 -23.9 0 -23.7 -23.9 02/08/2005 14:30:00 9.4 1.1 11.8 6.1 9.5 1.2 12.6 6.1 0.4 0 0.4 0.4 1 6 359 305 1 0 1 0 -23.9 0 -23.7 -24.1 02/08/2005 14:40:00 8.8 1 10.7 6.1 8.9 1 11.1 6.1 0.4 0 0.4 0.4 357 6 5 305 1 0 1 0 -23.8 0.1 -23.6 -23.9 02/08/2005 14:50:00 7.7 0.8 10.3 5.3 7.8 0.8 11.1 4.9 0.4 0 0.4 0.4 359 9 357 305 1 0 1 0 -23.9 0 -23.6 -23.9 02/08/2005 15:00:00 7.9 0.8 9.9 5.7 8 0.8 10.3 6.1 0.4 0 0.4 0.4 356 6 1 305 1 0 1 0 -23.7 0 -23.4 -23.9 02/08/2005 15:10:00 8.5 0.8 9.9 6.5 8.6 0.8 10.7 6.5 0.4 0 0.4 0.4 350 6 340 305 1 0 1 0 -23.6 0 -23.4 -23.9 02/08/2005 15:20:00 8 0.8 9.9 6.1 8 0.8 10.3 6.1 0.4 0 0.4 0.4 351 9 345 305 1 0 1 0 -23.6 0 -23.4 -23.9 02/08/2005 15:30:00 8.5 0.6 9.9 6.1 8.7 0.7 10.3 6.5 0.4 0 0.4 0.4 342 5 347 305 1 0 1 0 -23.5 0 -23.4 -23.6 02/08/2005 15:40:00 8 0.7 9.5 5.7 8.1 0.8 10.3 5.7 0.4 0 0.4 0.4 344 6 338 305 1 0 1 0 -23.4 0 -23.2 -23.6 02/08/2005 15:50:00 8 0.6 9.1 6.1 8.2 0.6 9.9 6.8 0.4 0 0.4 0.4 340 6 348 305 1 0 1 0 -23.5 0.1 -23.4 -23.9 02/08/2005 16:00:00 7.7 0.8 10.3 5.7 7.9 0.9 11.1 5.7 0.4 0 0.4 0.4 341 5 343 305 1 0 1 0 -23.8 0 -23.7 -23.9 02/08/2005 16:10:00 6.8 0.6 8.4 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 338 8 342 305 1 0 1 0 -23.9 0 -23.7 -23.9 02/08/2005 16:20:00 6.3 0.7 8 4.6 6.4 0.7 8.4 4.6 0.4 0 0.4 0.4 342 7 332 305 1 0 1 0 -23.8 0 -23.7 -23.9 02/08/2005 16:30:00 6.3 1 8.4 3.8 6.4 1 8.4 3.8 0.4 0 0.4 0.4 342 8 339 305 1 0 1 0 -23.8 0.1 -23.4 -23.9 02/08/2005 16:40:00 7.1 0.7 9.1 4.9 7.2 0.7 9.1 5.3 0.4 0 0.4 0.4 343 7 352 305 1 0 1 0 -24 0 -23.9 -24.2 02/08/2005 16:50:00 6.9 0.7 9.5 4.9 7.1 0.7 9.1 4.9 0.4 0 0.4 0.4 343 6 339 305 1 0 1 0 -23.9 0 -23.9 -24.1 02/08/2005 17:00:00 6.2 0.8 8.4 3.8 6.4 0.9 8 3.8 0.4 0 0.4 0.4 344 7 348 305 1 0 1 0 -23.9 0 -23.7 -23.9 02/08/2005 17:10:00 6.4 0.9 8 3.4 6.5 0.9 8.4 4.2 0.4 0 0.4 0.4 340 8 348 305 1 0 1 0 -23.7 0 -23.6 -23.9 02/08/2005 17:20:00 5.6 1 8.4 3.4 5.7 1 8.8 3.4 0.4 0 0.4 0.4 335 8 339 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 02/08/2005 17:30:00 6 0.8 8 3.4 6.2 0.8 8.4 3.8 0.4 0 0.4 0.4 342 6 341 305 1 0 1 0 -23.6 0 -23.4 -23.9 02/08/2005 17:40:00 5.3 0.6 6.8 3.4 5.5 0.7 6.8 3.8 0.4 0 0.4 0.4 338 7 338 305 1 0 1 0 -23.6 0 -23.4 -23.9 02/08/2005 17:50:00 7.6 2.2 11.5 4.2 7.4 2 11.1 3.8 0.4 0 0.4 0.4 314 12 305 305 1 0 0 0 -23.4 0.1 -23.2 -23.7 02/08/2005 18:00:00 9.2 1.1 11.8 6.5 9 1 11.5 6.1 0.4 0 0.4 0.4 309 10 317 305 1 0 2 0 -23.3 0 -23.2 -23.4 02/08/2005 18:10:00 10.9 1.3 13.7 7.2 10.5 1.2 13 7.2 0.4 0 0.4 0.4 308 13 305 305 1 1 0 0 -23.4 0 -23.2 -23.6 02/08/2005 18:20:00 11.2 1 13.7 8.8 10.9 1 13 7.6 0.4 0 0.4 0.4 310 15 302 305 1 0 0 0 -23.5 0 -23.4 -23.7 02/08/2005 18:30:00 10.4 1.1 13 7.6 10.3 1.2 13.3 7.2 0.4 0 0.4 0.4 312 10 315 305 1 0 1 0 -23.5 0 -23.4 -23.7 02/08/2005 18:40:00 9.5 1.1 12.6 6.5 9.3 1.1 11.8 6.5 0.4 0 0.4 0.4 310 11 302 305 1 0 1 0 -23.6 0 -23.4 -23.7 02/08/2005 18:50:00 9.6 1 12.2 6.8 9.4 1.1 11.8 6.5 0.4 0 0.4 0.4 311 7 305 305 1 0 2 0 -23.6 0.1 -23.4 -23.9 02/08/2005 19:00:00 9.8 0.9 11.8 7.2 9.7 1 11.8 7.2 0.4 0 0.4 0.4 311 7 318 305 1 0 1 0 -23.8 0 -23.6 -23.9 02/08/2005 19:10:00 9.4 1 11.8 7.2 9.2 1 12.2 6.8 0.4 0 0.4 0.4 312 13 305 305 1 0 1 0 -23.8 0 -23.6 -23.9 02/08/2005 19:20:00 9 1 11.5 6.5 8.8 0.9 11.1 6.5 0.4 0 0.4 0.4 311 10 303 305 1 0 0 0 -23.8 0 -23.2 -23.9 02/08/2005 19:30:00 9.5 0.7 11.5 7.2 9.2 0.8 11.1 6.8 0.4 0 0.4 0.4 307 18 316 305 1 1 1 0 -23.9 0 -23.7 -23.9 02/08/2005 19:40:00 9.8 0.8 12.2 7.6 9.5 0.9 12.2 7.2 0.4 0 0.4 0.4 307 13 306 305 1 1 1 0 -23.9 0 -23.7 -23.9 02/08/2005 19:50:00 10 1.1 12.2 7.6 9.7 1.1 12.6 7.2 0.4 0 0.4 0.4 309 14 303 305 1 1 0 0 -23.9 0 -23.7 -23.9 02/08/2005 20:00:00 9.5 0.8 11.5 7.2 9.3 0.8 11.1 7.2 0.4 0 0.4 0.4 310 11 307 305 1 0 1 0 -23.8 0 -23.2 -23.9 02/08/2005 20:10:00 9.8 1.1 11.8 6.8 9.4 1.1 11.8 6.5 0.4 0 0.4 0.4 309 16 313 305 1 0 0 0 -23.7 0.1 -23.2 -23.9 02/08/2005 20:20:00 9.2 0.8 11.1 7.2 8.9 0.8 11.1 6.5 0.4 0 0.4 0.4 303 15 300 305 1 0 0 0 -23.6 0.1 -23.2 -23.7 02/08/2005 20:30:00 9.4 1 11.5 6.8 9.2 1 11.5 6.5 0.4 0 0.4 0.4 307 9 298 305 1 1 1 0 -23.5 0 -22.9 -23.7 02/08/2005 20:40:00 9.1 1 11.1 6.5 8.6 1 10.7 6.1 0.4 0 0.4 0.4 303 8 288 305 1 1 0 0 -23.6 0.1 -22.9 -23.9 02/08/2005 20:50:00 9.4 1 11.5 6.8 9 1 11.5 6.8 0.4 0 0.4 0.4 302 20 305 305 1 1 1 0 -23.6 0.1 -23 -23.7 02/08/2005 21:00:00 10.4 1 12.2 7.2 9.8 1 11.8 6.8 0.4 0 0.4 0.4 296 5 296 305 0 0 0 0 -23.6 0 -23 -23.9 02/08/2005 21:10:00 9 1 11.5 6.8 8.5 1 11.1 6.5 0.4 0 0.4 0.4 300 10 295 305 0 0 0 0 -23.6 0 -23.4 -23.7 02/08/2005 21:20:00 9.6 0.7 11.5 7.6 9 0.9 11.1 7.2 0.4 0 0.4 0.4 298 10 291 305 0 0 0 0 -23.6 0 -23.4 -23.9 02/08/2005 21:30:00 10 0.7 11.8 8 9.5 0.7 11.1 7.2 0.4 0 0.4 0.4 300 13 294 305 0 0 0 0 -23.6 0 -23.2 -23.7 02/08/2005 21:40:00 9.6 1.3 11.8 6.5 9.1 1.3 11.5 6.1 0.4 0 0.4 0.4 300 14 291 305 0 0 0 0 -23.5 0 -23.4 -23.7 02/08/2005 21:50:00 9.8 0.8 11.8 7.6 9.4 0.8 11.8 7.2 0.4 0 0.4 0.4 301 15 292 305 0 0 0 0 -23.5 0 -23.2 -23.6 02/08/2005 22:00:00 8.9 1 11.5 6.5 8.4 1 11.1 5.7 0.4 0 0.4 0.4 303 9 296 305 1 1 0 0 -23.4 0 -23.2 -23.6 02/08/2005 22:10:00 9.9 0.9 11.5 6.8 9.4 0.9 11.1 6.8 0.4 0 0.4 0.4 301 8 309 305 1 0 0 0 -23.4 0 -23.2 -23.4 02/08/2005 22:20:00 9 1 11.1 6.5 8.5 1 11.1 6.1 0.4 0 0.4 0.4 299 15 286 305 0 0 0 0 -23.3 0.1 -23.2 -23.4 02/08/2005 22:30:00 9.2 0.8 11.5 6.8 8.7 0.9 11.1 6.5 0.4 0 0.4 0.4 299 7 300 305 0 0 0 0 -23.3 0 -23.2 -23.4 02/08/2005 22:40:00 7.7 1 9.5 4.9 7.3 1 9.5 4.6 0.4 0 0.4 0.4 301 10 300 305 1 0 1 0 -23.2 0 -23 -23.4 02/08/2005 22:50:00 9.3 0.8 11.1 6.8 8.8 0.7 10.7 7.2 0.4 0 0.4 0.4 299 6 298 305 0 0 0 0 -23.2 0 -23 -23.4 02/08/2005 23:00:00 8.8 0.7 10.7 6.8 8.3 0.8 9.9 6.1 0.4 0 0.4 0.4 298 6 303 305 0 0 0 0 -23.2 0 -22.9 -23.2 02/08/2005 23:10:00 8.3 0.9 10.3 6.5 7.8 1 9.9 5.3 0.4 0 0.4 0.4 295 6 291 305 0 0 0 0 -23.1 0 -23 -23.2 02/08/2005 23:20:00 8.4 0.8 9.9 6.1 7.8 0.8 9.5 5.3 0.4 0 0.4 0.4 298 9 300 305 0 0 0 0 -23.1 0 -23 -23.2 02/08/2005 23:30:00 8.3 1 11.1 5.7 7.8 1 10.3 5.3 0.4 0 0.4 0.4 297 13 299 305 0 0 0 0 -23 0 -22.9 -23.2 02/08/2005 23:40:00 8.4 0.9 11.1 5.7 7.7 0.9 9.9 4.9 0.4 0 0.4 0.4 296 10 287 305 0 0 0 0 -23 0 -22.9 -23.2 02/08/2005 23:50:00 8.8 1 11.8 6.1 8.4 1.1 10.7 5.7 0.4 0 0.4 0.4 298 14 303 305 0 0 0 0 -22.9 0 -22.9 -23 02/09/2005 00:00:00 8 0.9 9.9 6.1 7.5 1 9.5 4.6 0.4 0 0.4 0.4 299 10 305 305 1 0 0 0 -22.9 0.1 -22.5 -23.2 02/09/2005 00:10:00 7.9 1.2 10.3 4.9 7.2 1.2 9.5 4.6 0.4 0 0.4 0.4 292 7 282 305 0 0 0 0 -22.9 0 -22.5 -23.2 02/09/2005 00:20:00 8.2 0.9 10.7 6.1 7.7 1 9.9 5.3 0.4 0 0.4 0.4 299 12 300 305 0 0 0 0 -22.9 0 -22.5 -23.2 02/09/2005 00:30:00 8.4 1.1 10.7 6.1 7.8 1.2 10.3 5.3 0.4 0 0.4 0.4 299 15 305 305 0 0 0 0 -22.9 0 -22.5 -23.2 02/09/2005 00:40:00 8 0.7 9.9 6.1 7.6 0.7 9.5 5.3 0.4 0 0.4 0.4 301 8 300 305 1 0 0 0 -22.9 0 -22.5 -23.2 02/09/2005 00:50:00 7.6 0.8 9.9 5.7 7.2 0.9 9.5 5.7 0.4 0 0.4 0.4 299 10 305 305 0 0 0 0 -22.9 0 -22.5 -23 02/09/2005 01:00:00 7.7 0.9 9.5 5.7 7.2 0.9 9.5 4.9 0.4 0 0.4 0.4 297 9 303 305 0 0 0 0 -22.9 0 -22.4 -23 02/09/2005 01:10:00 7.6 1 9.5 4.9 6.6 1.1 8.8 3.8 0.4 0 0.4 0.4 286 9 275 305 0 0 0 0 -22.7 0.1 -22.2 -22.9 02/09/2005 01:20:00 8.4 0.8 11.1 5.7 7.3 1.1 10.7 4.6 0.4 0 0.4 0.4 285 9 300 305 0 0 0 0 -22.7 0 -22.2 -22.9 02/09/2005 01:30:00 8.5 1.1 11.1 4.6 7.2 1.1 9.5 4.2 0.4 0 0.4 0.4 282 6 275 305 0 0 0 0 -22.7 0 -22 -22.9 02/09/2005 01:40:00 8.7 1.1 11.1 5.3 7 1.1 9.1 3.8 0.4 0 0.4 0.4 278 7 282 305 0 0 0 0 -22.7 0 -22.2 -22.7 02/09/2005 01:50:00 8.5 1.1 11.1 5.3 6.9 1.2 9.5 3.8 0.4 0 0.4 0.4 281 8 282 305 0 0 0 0 -22.6 0 -22.2 -22.7 02/09/2005 02:00:00 8.8 1.2 11.1 5.7 7.5 1.3 10.3 4.2 0.4 0 0.4 0.4 283 6 280 305 0 0 0 0 -22.5 0.1 -22 -22.7 02/09/2005 02:10:00 9.4 1 11.5 6.5 8.1 1.1 10.7 4.9 0.4 0 0.4 0.4 282 7 285 305 0 0 0 0 -22.6 0 -22 -22.7 02/09/2005 02:20:00 9.5 1.2 12.6 6.5 8 1.2 11.1 4.6 0.4 0 0.4 0.4 282 8 270 305 0 0 0 0 -22.5 0.1 -22 -22.7 02/09/2005 02:30:00 10 0.8 11.8 8.4 9.2 0.8 11.1 6.5 0.4 0 0.4 0.4 291 5 285 305 0 0 0 0 -22.6 0.1 -22 -22.7 02/09/2005 02:40:00 9.4 1 11.8 6.8 8.8 1.1 11.1 6.1 0.4 0 0.4 0.4 295 6 301 305 0 0 0 0 -22.5 0.1 -21.8 -22.7 02/09/2005 02:50:00 10.1 1.1 12.6 7.6 9.2 1.2 11.8 6.5 0.4 0 0.4 0.4 291 8 290 305 0 0 0 0 -22.4 0 -21.8 -22.5 02/09/2005 03:00:00 9.3 1 11.1 6.8 8.5 1 10.7 5.3 0.4 0 0.4 0.4 293 8 303 305 0 0 0 0 -22.5 0 -22.4 -22.7 02/09/2005 03:10:00 9.6 1 12.2 6.8 8.9 1.1 11.5 5.7 0.4 0 0.4 0.4 296 19 297 305 0 0 0 0 -22.5 0 -22.4 -22.5 02/09/2005 03:20:00 9.1 1.3 11.8 5.3 8.4 1.3 11.1 4.9 0.4 0 0.4 0.4 292 7 293 305 0 0 0 0 -22.4 0 -22.4 -22.5 02/09/2005 03:30:00 9.1 1.2 12.6 5.7 8 1.3 11.5 5.3 0.4 0 0.4 0.4 288 8 302 305 0 0 0 0 -22.4 0 -22.4 -22.5 02/09/2005 03:40:00 9.8 1.3 12.6 6.5 8.3 1.3 11.1 4.9 0.4 0 0.4 0.4 283 7 286 305 0 0 0 0 -22.4 0 -22.2 -22.5 02/09/2005 03:50:00 10.2 1.2 12.2 7.2 9.1 1.3 11.5 5.3 0.4 0 0.4 0.4 285 6 290 305 0 0 0 0 -22.4 0 -22.4 -22.5 02/09/2005 04:00:00 10 1.1 12.2 5.7 8.9 1.2 11.8 4.6 0.4 0 0.4 0.4 290 12 305 305 0 0 0 0 -22.4 0.1 -21.8 -22.5 02/09/2005 04:10:00 9.9 1.2 12.6 6.8 8.1 1 10.7 5.3 0.4 0 0.4 0.4 281 8 279 305 0 0 0 0 -22.4 0 -21.8 -22.5 02/09/2005 04:20:00 10.2 1.1 12.6 7.2 8.5 1.2 11.5 5.7 0.4 0 0.4 0.4 282 8 278 305 0 0 0 0 -22.4 0 -22 -22.5 02/09/2005 04:30:00 10 1.3 12.6 5.7 9 1.3 11.5 5.7 0.4 0 0.4 0.4 288 6 280 305 0 0 0 0 -22.4 0 -22 -22.5 02/09/2005 04:40:00 10.7 1.3 14.1 6.5 9.6 1.3 13 6.5 0.4 0 0.4 0.4 289 7 288 305 0 0 0 0 -22.4 0 -21.8 -22.5 02/09/2005 04:50:00 10.1 1 13 7.6 9 1.2 11.8 5.3 0.4 0 0.4 0.4 289 7 293 305 0 0 0 0 -22.4 0 -21.8 -22.5 02/09/2005 05:00:00 10 1.3 13 6.5 8.6 1.5 11.8 4.9 0.4 0 0.4 0.4 285 7 278 305 0 0 0 0 -22.3 0 -22 -22.4 02/09/2005 05:10:00 10.4 1.3 13 7.2 9.4 1.3 12.2 6.5 0.4 0 0.4 0.4 289 6 285 305 0 0 0 0 -22.2 0 -22 -22.4 02/09/2005 05:20:00 10.7 1 13 8 9.8 1 12.2 8 0.4 0 0.4 0.4 291 6 293 305 0 0 0 0 -22.2 0 -22 -22.4 02/09/2005 05:30:00 10.8 1.1 13 7.6 9.7 1.2 12.6 5.3 0.4 0 0.4 0.4 288 9 293 305 0 0 0 0 -22.1 0 -21.8 -22.2 02/09/2005 05:40:00 10.1 1.5 13.3 6.5 9.2 1.5 13 5.3 0.4 0 0.4 0.4 289 12 285 305 0 0 0 0 -22.1 0 -22 -22.4 02/09/2005 05:50:00 9.5 1.2 12.2 6.8 8.6 1.2 12.2 5.7 0.4 0 0.4 0.4 291 7 286 305 0 0 0 0 -22.1 0 -22 -22.2 02/09/2005 06:00:00 10.3 1.6 13.3 4.9 9 1.7 13 4.2 0.4 0 0.4 0.4 286 7 287 305 0 0 0 0 -22.1 0 -21.8 -22.2 02/09/2005 06:10:00 10.6 1.3 13.7 7.2 9.4 1.4 12.6 5.7 0.4 0 0.4 0.4 286 8 290 305 0 0 0 0 -22.1 0 -21.8 -22.4 02/09/2005 06:20:00 10.3 1.2 13.7 7.2 8.8 1.4 12.2 5.3 0.4 0 0.4 0.4 283 7 288 305 0 0 1 0 -22.1 0 -21.8 -22.2 02/09/2005 06:30:00 9.3 1.1 11.8 6.8 7.9 1.4 11.1 4.2 0.4 0 0.4 0.4 283 9 292 305 0 0 0 0 -22.1 0 -21.8 -22.2 02/09/2005 06:40:00 9.4 1.1 11.8 6.5 8.2 1.2 10.7 5.3 0.4 0 0.4 0.4 285 7 287 305 0 0 0 0 -22.1 0 -21.8 -22.2 02/09/2005 06:50:00 10.2 1 12.2 7.2 8.9 1 11.5 5.3 0.4 0 0.4 0.4 286 6 284 305 0 0 0 0 -22.1 0 -21.8 -22.2 02/09/2005 07:00:00 10 1.1 12.2 6.8 8.8 1.1 11.8 5.7 0.4 0 0.4 0.4 286 6 303 305 0 0 0 0 -22 0 -21.8 -22.2 02/09/2005 07:10:00 10.1 1.1 12.2 6.8 8.8 1.2 11.5 5.3 0.4 0 0.4 0.4 285 7 285 305 0 0 0 0 -21.9 0 -21.8 -22 02/09/2005 07:20:00 10.5 1 12.6 6.8 9.1 1.3 12.2 4.9 0.4 0 0.4 0.4 285 8 285 305 0 0 0 0 -21.9 0 -21.7 -22 02/09/2005 07:30:00 10 0.9 11.8 7.2 8.8 1 11.5 5.3 0.4 0 0.4 0.4 285 9 300 305 0 0 0 0 -21.9 0 -21.8 -22 02/09/2005 07:40:00 9.3 1 11.5 6.5 8 1 10.7 5.3 0.4 0 0.4 0.4 283 6 279 305 0 0 0 0 -21.9 0 -21.8 -22 02/09/2005 07:50:00 10.3 1.1 12.6 6.8 8.9 1 11.1 6.1 0.4 0 0.4 0.4 284 6 282 305 0 0 0 0 -21.9 0 -21.7 -22 02/09/2005 08:00:00 10.3 1 12.6 7.2 9.2 1.1 11.5 5.3 0.4 0 0.4 0.4 287 6 285 305 0 0 0 0 -21.9 0 -21.3 -22 02/09/2005 08:10:00 11 1 13.3 8 9.4 1.1 12.2 6.1 0.4 0 0.4 0.4 282 5 276 305 0 0 0 0 -21.8 0 -21.7 -22 02/09/2005 08:20:00 10.7 1.1 13.3 7.2 8.9 1.4 11.8 4.9 0.4 0 0.4 0.4 280 6 279 305 0 0 1 0 -21.7 0 -21.5 -21.8 02/09/2005 08:30:00 10.6 1.1 13.3 7.2 9.3 1.2 12.2 6.1 0.4 0 0.4 0.4 285 6 291 305 0 0 0 0 -21.8 0 -21.3 -21.8 02/09/2005 08:40:00 10.2 1.3 12.6 6.8 8.9 1.2 11.5 5.7 0.4 0 0.4 0.4 284 6 278 305 0 0 0 0 -21.7 0 -21.3 -21.8 02/09/2005 08:50:00 10.7 1 13.3 7.6 9.4 1.1 11.8 5.7 0.4 0 0.4 0.4 285 6 301 305 0 0 0 0 -21.7 0 -21.5 -21.8 02/09/2005 09:00:00 10.6 1.2 12.6 6.8 9.3 1.3 12.2 6.5 0.4 0 0.4 0.4 284 6 279 305 0 0 0 0 -21.7 0 -21.3 -21.8 02/09/2005 09:10:00 9.4 1 11.5 6.8 8 1.2 10.7 3.8 0.4 0 0.4 0.4 282 7 283 305 0 0 0 0 -21.7 0 -21.3 -21.8 02/09/2005 09:20:00 8.9 1 11.5 6.5 7.9 1.1 11.1 5.3 0.4 0 0.4 0.4 286 6 293 305 0 0 0 0 -21.7 0 -21.3 -21.8 02/09/2005 09:30:00 9.5 1.2 13 6.8 8.4 1.3 12.2 5.3 0.4 0 0.4 0.4 285 7 283 305 0 0 0 0 -21.7 0 -21.5 -21.8 02/09/2005 09:40:00 9.9 0.9 12.2 7.6 8.9 1 11.5 5.3 0.4 0 0.4 0.4 286 5 289 305 0 0 0 0 -21.6 0 -21.3 -21.7 02/09/2005 09:50:00 9.6 0.8 11.5 6.8 8.5 1 10.7 6.1 0.4 0 0.4 0.4 289 5 291 305 0 0 0 0 -21.6 0 -21.5 -21.7 02/09/2005 10:00:00 8.7 1 11.1 6.1 7.6 1.1 10.3 4.6 0.4 0 0.4 0.4 287 9 293 305 0 0 0 0 -21.5 0 -21.3 -21.7 02/09/2005 10:10:00 8.4 1.2 10.7 4.9 7.3 1.2 9.5 3.4 0.4 0 0.4 0.4 286 8 281 305 0 0 0 0 -21.5 0.1 -21.3 -21.7 02/09/2005 10:20:00 9.4 1 12.2 6.1 8.1 1 10.7 5.7 0.4 0 0.4 0.4 284 7 287 305 0 0 1 0 -21.3 0 -21.1 -21.5 02/09/2005 10:30:00 9.3 1.2 11.8 5.7 7.8 1.4 10.7 4.6 0.4 0 0.4 0.4 282 8 281 305 0 0 0 0 -21.3 0 -21.1 -21.3 02/09/2005 10:40:00 9 0.9 11.1 6.1 7.2 1.1 9.9 4.6 0.4 0 0.4 0.4 278 9 284 305 1 0 1 0 -21.2 0 -21 -21.3 02/09/2005 10:50:00 10.3 0.8 12.2 7.2 8.1 1.1 11.1 5.3 0.4 0 0.4 0.4 277 9 276 305 1 0 1 0 -21.2 0 -21 -21.3 02/09/2005 11:00:00 8.6 1.1 11.5 5.7 7 1.1 9.5 3.4 0.4 0 0.4 0.4 281 9 268 305 1 0 0 0 -21.2 0 -21 -21.3 02/09/2005 11:10:00 8.8 1.1 11.5 5.3 6.8 1.1 9.9 3.8 0.4 0 0.4 0.4 276 8 286 305 1 0 1 0 -21.1 0 -20.8 -21.3 02/09/2005 11:20:00 10.5 1.3 13 6.5 8.4 1.5 11.5 4.6 0.4 0 0.4 0.4 278 7 283 305 1 0 0 0 -20.9 0 -20.8 -21.1 02/09/2005 11:30:00 9.3 1.3 12.2 5.7 7.2 1.3 10.7 3.8 0.4 0 0.4 0.4 275 8 285 305 1 0 0 0 -20.8 0 -20.6 -21 02/09/2005 11:40:00 9.2 1.4 12.2 5.7 6.5 1.2 9.9 3.4 0.4 0 0.4 0.4 269 7 272 305 1 0 1 0 -20.8 0 -20.4 -21 02/09/2005 11:50:00 9.1 1.1 11.5 5.7 6.9 1.1 9.5 4.2 0.4 0 0.4 0.4 273 7 274 305 1 0 0 0 -20.7 0 -20.4 -21 02/09/2005 12:00:00 9.5 1.1 12.2 6.5 7 1 9.1 4.2 0.4 0 0.4 0.4 271 7 275 305 1 0 1 0 -20.6 0 -20.2 -20.8 02/09/2005 12:10:00 9.7 1.4 12.6 5.7 7 1.3 9.9 3.8 0.4 0 0.4 0.4 270 7 273 305 1 0 1 0 -20.6 0 -20.2 -20.8 02/09/2005 12:20:00 9.4 1.1 11.5 5.7 6.9 1.1 9.9 3.8 0.4 0 0.4 0.4 271 8 263 305 1 0 1 0 -20.5 0 -20.1 -20.8 02/09/2005 12:30:00 8.3 1.2 10.7 4.9 6.2 1.2 9.9 3.8 0.4 0 0.4 0.4 272 9 265 305 1 0 1 0 -20.5 0 -20.1 -20.8 02/09/2005 12:40:00 9.4 1 11.1 6.8 7.5 1.1 9.9 4.2 0.4 0 0.4 0.4 278 7 293 305 1 0 1 0 -20.5 0 -20.1 -20.6 02/09/2005 12:50:00 8.8 1.3 11.5 4.6 6.4 1.1 9.1 3.8 0.4 0 0.4 0.4 266 8 267 305 1 0 1 0 -20.4 0 -20.1 -20.6 02/09/2005 13:00:00 8.1 1.2 11.1 4.6 6 1 8.8 3 0.4 0 0.4 0.4 273 8 268 305 1 0 1 0 -20.4 0 -20.1 -20.6 02/09/2005 13:10:00 8.7 1 10.7 5.7 6.5 1.1 9.9 4.2 0.4 0 0.4 0.4 273 6 279 305 1 0 1 0 -20.4 0 -20.1 -20.6 02/09/2005 13:20:00 7.5 0.8 9.9 5.3 6.1 1 8.4 3.4 0.4 0 0.4 0.4 278 7 270 305 1 0 1 0 -20.3 0 -20.1 -20.4 02/09/2005 13:30:00 8.3 1.1 10.3 4.9 6.2 1 8.4 3.4 0.4 0 0.4 0.4 270 9 254 305 1 0 1 0 -20.4 0 -20.1 -20.6 02/09/2005 13:40:00 7 1.3 9.5 3.8 5.6 1.1 8.4 2.6 0.4 0 0.4 0.4 277 9 282 305 1 0 1 0 -20.4 0 -20.1 -20.6 02/09/2005 13:50:00 6.7 1.2 9.5 3.8 5.3 1.2 8.8 2.6 0.4 0 0.4 0.4 279 9 290 305 1 0 1 0 -20.4 0 -20.1 -20.6 02/09/2005 14:00:00 6.6 1 8.8 3.8 5.1 1.1 7.6 2.6 0.4 0 0.4 0.4 274 10 267 305 1 0 1 0 -20.3 0 -20.1 -20.4 02/09/2005 14:10:00 7.1 1 9.1 3.4 5.2 1 8 2.3 0.4 0 0.4 0.4 273 9 268 305 1 0 1 0 -20.2 0 -19.9 -20.6 02/09/2005 14:20:00 6.6 1 8.4 3.4 4.9 1 7.6 2.6 0.4 0 0.4 0.4 271 9 283 305 1 0 1 0 -20.2 0 -19.9 -20.2 02/09/2005 14:30:00 7.1 1.2 9.9 3.8 5.3 1.1 8 2.6 0.4 0 0.4 0.4 275 8 277 305 1 0 1 0 -20.2 0 -19.7 -20.4 02/09/2005 14:40:00 6.9 1.2 9.5 3.4 5.1 1.1 8 2.6 0.4 0 0.4 0.4 272 9 265 305 1 0 1 0 -20.1 0.1 -19.5 -20.1 02/09/2005 14:50:00 6.9 1.1 8.8 3 5.3 1.1 7.6 1.9 0.4 0 0.4 0.4 273 7 275 305 1 0 1 0 -20.1 0 -19.5 -20.1 02/09/2005 15:00:00 6.3 1.2 9.1 3 4.7 1 7.2 2.6 0.4 0 0.4 0.4 273 8 276 305 1 0 1 0 -20.2 0 -19.9 -20.4 02/09/2005 15:10:00 7 0.8 9.1 4.9 5.2 0.8 7.2 3.4 0.4 0 0.4 0.4 271 9 266 305 1 0 1 0 -20.1 0 -19.7 -20.2 02/09/2005 15:20:00 6.8 1.1 9.1 4.2 5.4 1.1 8.8 3 0.4 0 0.4 0.4 278 9 285 305 1 0 1 0 -20.2 0 -19.7 -20.1 02/09/2005 15:30:00 6.9 1 9.1 4.2 5.5 1.1 7.6 3 0.4 0 0.4 0.4 273 10 267 305 1 0 1 0 -20.2 0 -19.9 -20.2 02/09/2005 15:40:00 6.5 0.9 9.1 4.2 4.9 0.8 7.2 2.6 0.4 0 0.4 0.4 271 8 270 305 1 0 1 0 -20.1 0.1 -19.5 -20.1 02/09/2005 15:50:00 5.9 1.1 8 3 4.6 1.1 6.8 1.9 0.4 0 0.4 0.4 274 9 265 305 1 0 1 0 -20 0.1 -19.5 -20.1 02/09/2005 16:00:00 6.1 1.1 8.4 2.6 4.6 1 7.2 2.3 0.4 0 0.4 0.4 271 8 275 305 1 0 1 0 -19.9 0 -19.5 -20.1 02/09/2005 16:10:00 6.5 1 8.8 4.2 4.9 1 7.2 2.6 0.4 0 0.4 0.4 260 8 258 305 1 0 1 0 -19.8 0.1 -19.5 -19.9 02/09/2005 16:20:00 7.3 1 9.9 4.9 5.5 0.8 7.6 3.4 0.4 0 0.4 0.4 273 9 277 305 1 0 1 0 -19.7 0.1 -19.3 -19.9 02/09/2005 16:30:00 6.6 0.8 8.8 4.2 5.1 0.8 7.2 3 0.4 0 0.4 0.4 273 9 273 305 1 0 1 0 -19.8 0 -19.5 -19.9 02/09/2005 16:40:00 7.2 0.9 10.3 4.9 5.8 1 8.4 3 0.4 0 0.4 0.4 281 8 268 305 1 0 1 0 -19.8 0.1 -19.5 -20.1 02/09/2005 16:50:00 7.9 1.3 10.3 4.6 6.4 1.4 9.9 3.4 0.4 0 0.4 0.4 276 10 278 305 1 0 1 0 -19.9 0.1 -19.5 -20.1 02/09/2005 17:00:00 7.7 1.1 10.3 4.2 5.6 1 8.8 3.4 0.4 0 0.4 0.4 265 8 261 305 1 0 1 0 -19.9 0 -19.5 -20.1 02/09/2005 17:10:00 6.6 0.9 8.8 4.2 5.1 0.9 6.8 3 0.4 0 0.4 0.4 273 9 269 305 1 0 1 0 -19.8 0 -19.5 -20.1 02/09/2005 17:20:00 7.2 1 10.3 4.2 5.3 0.9 8.4 3 0.4 0 0.4 0.4 264 6 259 305 1 0 1 0 -19.8 0.1 -19.5 -20.1 02/09/2005 17:30:00 6.6 1.1 9.5 4.2 4.8 1 7.2 2.3 0.4 0 0.4 0.4 271 7 266 305 1 0 1 0 -19.7 0 -19.3 -19.9 02/09/2005 17:40:00 7.9 1 10.3 4.9 6.2 1 9.1 3.8 0.4 0 0.4 0.4 276 8 282 305 1 0 1 0 -19.7 0 -19.3 -19.9 02/09/2005 17:50:00 7.9 1.2 10.7 4.9 5.9 1 8.8 3.4 0.4 0 0.4 0.4 264 7 263 305 1 0 1 0 -19.8 0 -19.5 -19.9 02/09/2005 18:00:00 8.1 0.9 10.7 5.7 5.8 0.9 8.8 3.4 0.4 0 0.4 0.4 269 6 270 305 1 0 1 0 -19.7 0.1 -19.5 -19.9 02/09/2005 18:10:00 6.8 1.4 10.3 3.8 4.9 1.2 8 2.3 0.4 0 0.4 0.4 265 9 254 305 1 0 1 0 -19.8 0 -19.5 -20.1 02/09/2005 18:20:00 8.1 1 10.3 5.7 5.8 0.9 8 3 0.4 0 0.4 0.4 266 9 261 305 1 0 1 0 -19.7 0.1 -19.5 -19.9 02/09/2005 18:30:00 7.6 1.1 9.9 4.9 5.7 1 8.4 3.4 0.4 0 0.4 0.4 274 8 277 305 1 0 1 0 -19.7 0 -19.3 -19.9 02/09/2005 18:40:00 8 0.9 9.9 5.7 6.4 0.9 8.8 4.2 0.4 0 0.4 0.4 279 7 274 305 1 0 1 0 -19.7 0.1 -19.5 -19.9 02/09/2005 18:50:00 7.4 1.2 9.9 4.2 5.4 1 8 3 0.4 0 0.4 0.4 268 12 256 305 1 0 1 0 -19.7 0 -19.5 -19.9 02/09/2005 19:00:00 8 0.9 9.9 5.7 6.5 0.9 8.8 4.2 0.4 0 0.4 0.4 280 6 290 305 1 0 1 0 -19.7 0 -19.3 -19.9 02/09/2005 19:10:00 7.8 1.1 10.7 5.3 6.4 1.1 9.9 3.4 0.4 0 0.4 0.4 282 7 283 305 1 0 1 0 -19.6 0 -19.3 -19.7 02/09/2005 19:20:00 7.9 1 10.3 5.3 6.3 1.1 9.1 3.8 0.4 0 0.4 0.4 278 7 281 305 1 0 1 0 -19.6 0 -19.2 -19.7 02/09/2005 19:30:00 7.7 1 9.9 4.6 5.6 1 8.8 3 0.4 0 0.4 0.4 273 8 279 305 1 0 1 0 -19.6 0 -19.3 -19.7 02/09/2005 19:40:00 6.9 1.1 9.1 4.2 5.3 0.9 7.6 2.6 0.4 0 0.4 0.4 275 6 282 305 1 0 1 0 -19.6 0 -19.2 -19.7 02/09/2005 19:50:00 7.2 0.8 9.1 4.9 5.6 1 7.6 3 0.4 0 0.4 0.4 277 9 279 305 1 0 1 0 -19.6 0 -19.2 -19.5 02/09/2005 20:00:00 6.8 1 8.8 4.2 5.6 1 7.6 3 0.4 0 0.4 0.4 280 7 275 305 1 0 1 0 -19.5 0 -19.2 -19.5 02/09/2005 20:10:00 7.1 0.9 8.8 4.6 5.9 1 8 2.6 0.4 0 0.4 0.4 282 7 290 305 1 0 1 0 -19.5 0.1 -19 -19.5 02/09/2005 20:20:00 7.1 1.1 9.5 3.8 5.4 1 8.4 3 0.4 0 0.4 0.4 274 8 296 305 1 0 1 0 -19.3 0 -19 -19.5 02/09/2005 20:30:00 6.1 0.8 8.4 4.2 4.6 0.9 7.2 2.3 0.4 0 0.4 0.4 275 11 289 305 1 0 1 0 -19.3 0 -19 -19.5 02/09/2005 20:40:00 7 1 8.8 4.2 6 1 8 3 0.4 0 0.4 0.4 285 7 280 305 1 0 1 0 -19.3 0.1 -19 -19.5 02/09/2005 20:50:00 6.7 1.1 9.1 3 5.1 0.9 7.2 2.6 0.4 0 0.4 0.4 274 9 275 305 1 0 1 0 -19.3 0 -19 -19.5 02/09/2005 21:00:00 5.5 1 8.4 3.4 4.2 1 7.2 1.9 0.4 0 0.4 0.4 274 9 290 305 1 0 1 0 -19.4 0.1 -19 -19.5 02/09/2005 21:10:00 6.9 1 9.1 4.6 5.2 0.9 7.6 2.6 0.4 0 0.4 0.4 271 9 273 305 1 0 1 0 -19.2 0 -19 -19.3 02/09/2005 21:20:00 7.6 1.2 10.3 3.4 5.7 1.1 7.6 2.3 0.4 0 0.4 0.4 274 7 274 305 1 0 1 0 -19.2 0 -19 -19.3 02/09/2005 21:30:00 8 0.8 9.9 5.3 5.7 0.8 7.6 3.8 0.4 0 0.4 0.4 264 6 262 305 1 0 1 0 -19.2 0 -19 -19.3 02/09/2005 21:40:00 8.7 1 10.7 5.3 7.1 1.3 9.5 3.4 0.4 0 0.4 0.4 253 7 250 305 1 0 1 0 -19.2 0 -19 -19.5 02/09/2005 21:50:00 7.8 1.1 10.3 4.9 5.8 0.8 8 3.4 0.4 0 0.4 0.4 260 7 263 305 1 0 1 0 -19.2 0 -19 -19.5 02/09/2005 22:00:00 7.5 1.1 9.9 4.6 5.9 1 8 3 0.4 0 0.4 0.4 254 6 270 305 1 0 1 0 -19.2 0 -19 -19.5 02/09/2005 22:10:00 8.1 1 10.3 4.9 5.7 0.8 7.6 3 0.4 0 0.4 0.4 264 6 269 305 1 0 1 0 -19.3 0 -19 -19.5 02/09/2005 22:20:00 7.9 0.9 9.9 5.3 5.8 0.8 8 3.4 0.4 0 0.4 0.4 263 7 275 305 1 0 1 0 -19.3 0 -19 -19.5 02/09/2005 22:30:00 7.7 1.1 10.3 4.6 5.6 0.9 8.4 3.8 0.4 0 0.4 0.4 262 6 261 305 1 0 1 0 -19.3 0 -19 -19.5 02/09/2005 22:40:00 7.7 1.5 10.3 4.6 5.5 1.2 8 2.6 0.4 0 0.4 0.4 263 7 259 305 1 0 1 0 -19.2 0 -19 -19.5 02/09/2005 22:50:00 7.7 1 10.3 5.3 5.7 0.8 8 3.4 0.4 0 0.4 0.4 260 7 266 305 1 0 1 0 -19.2 0 -19 -19.3 02/09/2005 23:00:00 8.3 1 11.1 5.7 6.7 1.1 9.1 3.8 0.4 0 0.4 0.4 256 6 264 305 1 0 1 0 -19.2 0 -19 -19.3 02/09/2005 23:10:00 8.4 1.2 11.1 4.6 6.7 1.4 10.3 3.8 0.4 0 0.4 0.4 253 9 237 305 1 0 1 0 -19.1 0 -18.8 -19.2 02/09/2005 23:20:00 8.4 1.1 10.7 5.3 6.9 1.3 9.9 3.8 0.4 0 0.4 0.4 252 8 248 305 1 0 1 0 -19.1 0 -18.6 -19.2 02/09/2005 23:30:00 7.5 1 9.9 4.6 5.7 1.1 8.8 3 0.4 0 0.4 0.4 257 8 258 305 1 0 1 0 -19.2 0 -18.8 -19.3 02/09/2005 23:40:00 8.3 0.9 10.3 5.7 6.1 1 8.4 3.4 0.4 0 0.4 0.4 260 7 261 305 1 0 1 0 -19.1 0 -18.8 -19.3 02/09/2005 23:50:00 8.1 1.3 10.7 4.6 6.5 1.2 9.5 3.4 0.4 0 0.4 0.4 253 7 259 305 1 0 1 0 -19.3 0 -19 -19.5 02/10/2005 00:00:00 9.7 1 12.2 7.2 7.9 1 11.5 5.7 0.4 0 0.4 0.4 254 7 266 305 1 0 1 0 -19.3 0 -19 -19.5 02/10/2005 00:10:00 9.5 1.2 11.8 6.5 7.8 1.3 10.7 5.3 0.4 0 0.4 0.4 253 5 250 305 1 0 1 0 -19.3 0 -19 -19.5 02/10/2005 00:20:00 8.5 1 10.3 6.1 6.1 0.9 8.8 3.8 0.4 0 0.4 0.4 265 7 265 305 1 0 1 0 -19.4 0 -19.2 -19.5 02/10/2005 00:30:00 8.3 1.1 10.3 4.9 6.1 1 8.8 3.4 0.4 0 0.4 0.4 261 7 265 305 1 0 1 0 -19.5 0 -19.3 -19.5 02/10/2005 00:40:00 8.2 1 10.3 4.9 6.5 1.2 9.1 3 0.4 0 0.4 0.4 257 7 256 305 1 0 1 0 -19.5 0 -19.3 -19.5 02/10/2005 00:50:00 7.3 1.2 9.9 4.2 6.1 1.2 9.1 3.4 0.4 0 0.4 0.4 252 6 254 305 1 0 1 0 -19.5 0.1 -19.2 -19.5 02/10/2005 01:00:00 7.4 0.7 9.1 5.3 6.2 0.9 8.4 3.8 0.4 0 0.4 0.4 251 7 238 305 1 0 1 0 -19.5 0.1 -19.2 -19.5 02/10/2005 01:10:00 8.3 1 10.7 5.3 6.6 1 9.5 3.8 0.4 0 0.4 0.4 253 7 236 305 1 0 1 0 -19.5 0.1 -19.2 -19.5 02/10/2005 01:20:00 8 1.1 10.7 4.6 6.7 1 9.1 3.4 0.4 0 0.4 0.4 251 6 258 305 1 0 1 0 -19.5 0 -19.2 -19.5 02/10/2005 01:30:00 7.7 1.1 9.9 4.9 6.3 1.1 8.8 3.8 0.4 0 0.4 0.4 252 7 249 305 1 0 1 0 -19.5 0.1 -19.2 -19.5 02/10/2005 01:40:00 7.9 1 10.3 5.3 6.7 1.1 9.5 3.8 0.4 0 0.4 0.4 252 5 251 305 1 0 1 0 -19.5 0.1 -19.2 -19.5 02/10/2005 01:50:00 7.2 1.1 10.3 4.6 5.8 1 8.4 3 0.4 0 0.4 0.4 252 8 261 305 1 0 1 0 -19.5 0.1 -19.2 -19.5 02/10/2005 02:00:00 8.2 1.1 10.3 5.7 6.7 1.1 9.5 3.8 0.4 0 0.4 0.4 253 7 254 305 1 0 1 0 -19.5 0 -19.2 -19.7 02/10/2005 02:10:00 7.8 1.5 11.1 4.6 6.4 1.4 11.1 3 0.4 0 0.4 0.4 252 6 248 305 1 0 1 0 -19.6 0 -19.3 -19.7 02/10/2005 02:20:00 7.3 1 9.9 4.9 5.9 1.1 8.4 3 0.4 0 0.4 0.4 254 6 255 305 1 0 1 0 -19.6 0 -19.3 -19.7 02/10/2005 02:30:00 6.7 0.8 8.8 4.2 5 0.8 7.2 3.4 0.4 0 0.4 0.4 261 7 261 305 1 0 1 0 -19.6 0 -19.3 -19.7 02/10/2005 02:40:00 7.4 1 9.9 4.6 5.4 0.9 8.4 3.4 0.4 0 0.4 0.4 263 6 258 305 1 0 1 0 -19.7 0 -19.5 -19.9 02/10/2005 02:50:00 7.8 1 9.9 5.3 5.6 0.9 8 3.8 0.4 0 0.4 0.4 266 7 268 305 1 0 1 0 -19.9 0.1 -19.5 -20.1 02/10/2005 03:00:00 9.3 1.1 11.8 5.7 6.6 1 9.1 3.8 0.4 0 0.4 0.4 268 7 262 305 1 0 1 0 -20.2 0 -19.9 -20.2 02/10/2005 03:10:00 8.6 1.5 12.6 4.9 6.2 1.3 9.5 3.4 0.4 0 0.4 0.4 268 8 268 305 0 0 0 0 -20.2 0 -20.1 -20.2 02/10/2005 03:20:00 8.6 1.3 11.1 4.6 6.4 1.2 9.1 3.8 0.4 0 0.4 0.4 261 8 249 305 0 0 0 0 -20.2 0 -19.9 -20.2 02/10/2005 03:30:00 8.2 1.1 10.7 4.6 6.5 1.1 9.1 3.4 0.4 0 0.4 0.4 256 6 258 305 0 0 0 0 -20.2 0 -19.9 -20.2 02/10/2005 03:40:00 8.8 1 11.1 6.5 7.3 1.1 9.9 4.2 0.4 0 0.4 0.4 251 5 255 305 0 0 0 0 -20.2 0 -20.1 -20.2 02/10/2005 03:50:00 7.7 0.8 9.9 4.9 6.1 0.9 8.4 4.2 0.4 0 0.4 0.4 254 7 253 305 1 0 1 0 -20.3 0.1 -20.1 -20.6 02/10/2005 04:00:00 7.7 0.9 11.1 5.3 6.6 0.8 9.5 4.2 0.4 0 0.4 0.4 249 7 242 305 1 0 0 0 -20.5 0 -20.2 -20.6 02/10/2005 04:10:00 9.3 1 11.8 6.5 7.7 1.2 10.3 4.2 0.4 0 0.4 0.4 251 7 254 305 1 0 1 0 -20.4 0 -20.1 -20.6 02/10/2005 04:20:00 9.2 1.1 11.8 5.7 7.2 1 10.3 4.6 0.4 0 0.4 0.4 256 7 254 305 0 0 1 0 -20.3 0.1 -20.1 -20.6 02/10/2005 04:30:00 8.4 1 10.7 5.7 6.6 1.1 9.5 3 0.4 0 0.4 0.4 259 10 256 305 0 0 1 0 -20.5 0 -20.2 -20.8 02/10/2005 04:40:00 7.8 0.8 10.3 5.7 5.7 0.8 8.4 3.8 0.4 0 0.4 0.4 267 7 271 305 0 0 0 0 -20.6 0 -20.4 -20.8 02/10/2005 04:50:00 8.4 0.9 10.3 5.7 6.1 0.8 8.4 3.8 0.4 0 0.4 0.4 270 6 273 305 0 0 0 0 -20.7 0 -20.4 -20.8 02/10/2005 05:00:00 7.8 0.8 9.9 5.7 5.8 0.7 7.6 3.8 0.4 0 0.4 0.4 262 6 261 305 0 0 0 0 -20.7 0 -20.6 -20.8 02/10/2005 05:10:00 8.2 0.8 10.3 6.1 5.9 0.7 7.6 3.8 0.4 0 0.4 0.4 265 5 268 305 0 0 0 0 -20.8 0 -20.6 -21 02/10/2005 05:20:00 7.3 1.1 9.5 4.6 5.3 0.9 7.6 3 0.4 0 0.4 0.4 266 7 261 305 0 0 0 0 -20.8 0 -20.8 -21 02/10/2005 05:30:00 7.8 0.7 9.5 5.7 5.6 0.8 8 3.4 0.4 0 0.4 0.4 268 9 263 305 0 0 0 0 -21 0 -20.8 -21.1 02/10/2005 05:40:00 7.9 0.8 9.9 5.3 6 0.8 8 3.4 0.4 0 0.4 0.4 260 7 265 305 0 0 0 0 -21 0 -20.8 -21.1 02/10/2005 05:50:00 7.5 0.9 9.5 4.9 5.3 0.9 7.2 3 0.4 0 0.4 0.4 264 8 268 305 0 0 0 0 -21 0 -20.8 -21.1 02/10/2005 06:00:00 6.3 1 9.1 3.8 4.6 0.8 6.5 2.6 0.4 0 0.4 0.4 261 7 265 305 0 0 0 0 -21 0 -20.8 -21.1 02/10/2005 06:10:00 7.1 0.9 9.1 4.2 5.9 1 8 3.4 0.4 0 0.4 0.4 251 6 258 305 0 0 0 0 -21 0 -20.8 -21.1 02/10/2005 06:20:00 7.4 1 9.1 4.6 6 0.9 8 3.4 0.4 0 0.4 0.4 254 6 251 305 0 0 1 0 -21 0 -20.8 -21.3 02/10/2005 06:30:00 7.4 0.8 9.1 5.3 5.4 0.6 7.2 3.8 0.4 0 0.4 0.4 266 6 264 305 0 0 0 0 -21.1 0 -20.8 -21.3 02/10/2005 06:40:00 6.6 1 9.5 4.6 4.7 1 7.6 2.6 0.4 0 0.4 0.4 264 8 261 305 0 0 0 0 -21.2 0 -21 -21.3 02/10/2005 06:50:00 7 0.9 9.1 4.9 5.1 0.8 7.6 3.4 0.4 0 0.4 0.4 263 7 269 305 0 0 0 0 -21.2 0 -21 -21.3 02/10/2005 07:00:00 7.9 1 9.9 4.9 5.9 1 8 3.8 0.4 0 0.4 0.4 259 6 259 305 0 0 0 0 -21.1 0 -21 -21.3 02/10/2005 07:10:00 8 1.1 11.1 4.6 6.1 1 9.1 3 0.4 0 0.4 0.4 257 7 259 305 0 0 0 0 -21.2 0 -21 -21.3 02/10/2005 07:20:00 8.4 0.9 10.7 6.5 6.3 1 9.5 4.2 0.4 0 0.4 0.4 260 7 262 305 0 0 0 0 -21.2 0 -21 -21.3 02/10/2005 07:30:00 7.7 1 9.9 5.3 6 0.9 8.8 3.4 0.4 0 0.4 0.4 258 6 237 305 0 0 0 0 -21.3 0 -21.1 -21.3 02/10/2005 07:40:00 7.7 0.9 9.5 4.6 6.1 1 8.8 3 0.4 0 0.4 0.4 254 6 252 305 0 0 0 0 -21.3 0 -21.3 -21.5 02/10/2005 07:50:00 7.5 0.9 9.5 5.7 6.2 0.7 8 3.4 0.4 0 0.4 0.4 252 6 256 305 0 0 0 0 -21.3 0 -21.1 -21.3 02/10/2005 08:00:00 6.9 0.6 8.4 5.3 5.6 0.9 7.2 3 0.4 0 0.4 0.4 253 8 268 305 0 0 0 0 -21.3 0 -21.3 -21.3 02/10/2005 08:10:00 6 0.8 8 4.2 4.5 0.6 6.1 3 0.4 0 0.4 0.4 259 6 254 305 0 0 0 0 -21.3 0 -21.3 -21.3 02/10/2005 08:20:00 6 0.9 8 4.2 4.9 1 7.2 3 0.4 0 0.4 0.4 252 5 248 305 0 0 0 0 -21.3 0 -21.3 -21.5 02/10/2005 08:30:00 6.2 0.6 7.6 4.6 5.4 0.6 6.8 3.8 0.4 0 0.4 0.4 250 3 250 305 0 0 0 0 -21.3 0 -20.8 -21.3 02/10/2005 08:40:00 4.9 0.5 6.1 3.8 4.1 0.6 5.7 2.6 0.4 0 0.4 0.4 253 4 252 305 0 0 0 0 -21.4 0 -21.3 -21.7 02/10/2005 08:50:00 4.4 0.5 6.1 3.4 3.6 0.5 4.9 2.3 0.4 0 0.4 0.4 253 5 246 305 0 0 0 0 -21.4 0.1 -21 -21.7 02/10/2005 09:00:00 4.9 0.7 6.8 3 4 0.8 6.5 1.9 0.4 0 0.4 0.4 253 8 242 305 0 0 0 0 -21.3 0 -21.1 -21.3 02/10/2005 09:10:00 6 0.7 7.2 3.4 5.1 0.8 6.5 2.3 0.4 0 0.4 0.4 246 5 245 305 0 0 0 0 -21.2 0 -21 -21.3 02/10/2005 09:20:00 5.3 0.5 6.8 4.2 4.6 0.5 6.1 3 0.4 0 0.4 0.4 243 4 245 305 0 0 0 0 -21.3 0 -21 -21.5 02/10/2005 09:30:00 4.4 0.4 5.7 3.4 4 0.5 5.3 2.6 0.4 0 0.4 0.4 233 4 239 305 0 0 0 0 -21.5 0.1 -21.3 -21.8 02/10/2005 09:40:00 4.5 0.5 5.7 3.4 4 0.5 5.3 2.6 0.4 0 0.4 0.4 235 7 231 305 0 0 0 0 -21.5 0.1 -21.3 -21.8 02/10/2005 09:50:00 5 0.7 6.5 3.4 4.2 0.6 5.7 2.6 0.4 0 0.4 0.4 244 9 256 305 0 0 0 0 -21.3 0.1 -21 -21.5 02/10/2005 10:00:00 5 0.8 6.8 2.6 4.3 0.9 6.5 2.6 0.4 0 0.4 0.4 239 15 225 305 1 0 1 0 -20.9 0.1 -20.8 -21.1 02/10/2005 10:10:00 6.5 0.6 8.4 4.6 6.2 0.6 8.4 4.6 0.4 0 0.4 0.4 223 6 227 305 1 0 1 0 -20.8 0 -20.8 -21 02/10/2005 10:20:00 5.8 0.5 6.8 4.2 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 220 4 223 305 1 0 1 0 -21 0 -20.8 -21.1 02/10/2005 10:30:00 6 0.8 7.6 4.2 5.7 0.8 7.2 3.4 0.4 0 0.4 0.4 219 5 225 305 1 0 1 0 -20.7 0 -20.6 -21 02/10/2005 10:40:00 7 0.5 8.8 5.3 6.7 0.6 8 4.9 0.4 0 0.4 0.4 218 5 216 305 1 0 1 0 -20.7 0 -20.4 -20.8 02/10/2005 10:50:00 7.2 0.5 8 5.7 7 0.6 8.4 4.9 0.4 0 0.4 0.4 216 3 218 305 1 0 1 0 -20.7 0 -20.4 -20.8 02/10/2005 11:00:00 5.6 0.7 7.6 4.2 5.4 0.8 7.2 3.8 0.4 0 0.4 0.4 211 4 216 305 1 0 1 0 -20.7 0 -20.4 -20.8 02/10/2005 11:10:00 7.4 0.6 9.5 5.7 7 0.7 8.8 4.9 0.4 0 0.4 0.4 214 5 215 305 1 0 1 0 -20.4 0 -20.1 -20.8 02/10/2005 11:20:00 7.1 0.5 8.4 5.7 6.8 0.6 8 4.9 0.4 0 0.4 0.4 219 3 222 305 1 0 1 0 -20.5 0 -20.1 -20.8 02/10/2005 11:30:00 6.8 0.5 8 4.9 6.6 0.6 8 4.9 0.4 0 0.4 0.4 219 4 218 305 1 0 1 0 -20.6 0 -20.2 -20.8 02/10/2005 11:40:00 6.8 0.5 8.4 4.9 6.6 0.6 8 4.9 0.4 0 0.4 0.4 218 4 216 305 1 0 1 0 -20.7 0 -20.4 -20.8 02/10/2005 11:50:00 6.2 0.5 7.6 4.9 5.9 0.6 7.6 4.6 0.4 0 0.4 0.4 220 4 215 305 1 0 1 0 -20.6 0 -20.2 -20.8 02/10/2005 12:00:00 6.4 0.5 7.6 4.9 6.1 0.5 7.2 4.6 0.4 0 0.4 0.4 219 4 219 305 1 0 1 0 -20.6 0.1 -20.1 -20.8 02/10/2005 12:10:00 7.2 0.5 8.4 5.7 7 0.6 8.8 4.9 0.4 0 0.4 0.4 215 3 215 305 1 0 1 0 -20.6 0.1 -20.1 -20.8 02/10/2005 12:20:00 7.3 0.6 8.8 5.3 7.1 0.7 8.8 5.3 0.4 0 0.4 0.4 216 3 210 305 1 0 1 0 -20.5 0.1 -20.1 -20.8 02/10/2005 12:30:00 7.6 0.6 8.8 5.3 7.3 0.7 8.8 5.3 0.4 0 0.4 0.4 214 4 213 305 1 0 1 0 -20.4 0.1 -19.9 -20.6 02/10/2005 12:40:00 7.4 0.6 8.8 5.3 7.1 0.7 8.4 4.9 0.4 0 0.4 0.4 218 5 219 305 1 0 1 0 -20.2 0 -19.7 -20.2 02/10/2005 12:50:00 7 0.5 8.4 6.1 6.8 0.5 8.4 5.3 0.4 0 0.4 0.4 217 4 221 305 1 0 1 0 -20.2 0 -19.7 -20.4 02/10/2005 13:00:00 7.1 0.6 8.4 5.3 6.8 0.7 8.8 4.9 0.4 0 0.4 0.4 216 5 216 305 1 0 1 0 -20.2 0 -19.5 -20.2 02/10/2005 13:10:00 6.9 0.6 8.4 5.3 6.6 0.6 8 4.9 0.4 0 0.4 0.4 218 5 227 305 2 0 1 0 -19.8 0.1 -19.3 -20.1 02/10/2005 13:20:00 6.3 0.6 7.6 4.9 6 0.6 7.2 4.2 0.4 0 0.4 0.4 214 5 224 305 2 0 1 0 -19.9 0 -19.3 -20.1 02/10/2005 13:30:00 6.7 0.5 7.6 5.3 6.7 0.5 8 4.6 0.4 0 0.4 0.4 209 3 213 305 2 0 2 0 -19.9 0.1 -19.3 -20.1 02/10/2005 13:40:00 6.5 0.5 7.6 4.6 6.3 0.7 8 4.2 0.4 0 0.4 0.4 212 5 210 305 2 0 1 0 -20 0.1 -19.5 -20.1 02/10/2005 13:50:00 6.8 0.5 8 5.3 6.6 0.7 7.6 4.9 0.4 0 0.4 0.4 214 4 213 305 1 0 1 0 -20.1 0.1 -19.5 -20.1 02/10/2005 14:00:00 6.8 0.8 8.8 4.9 6.8 0.8 8.8 4.9 0.4 0 0.4 0.4 209 4 205 305 1 0 1 0 -19.7 0.1 -19.2 -19.9 02/10/2005 14:10:00 6.8 0.6 8.4 4.9 6.4 0.6 8.4 4.6 0.4 0 0.4 0.4 219 5 223 305 1 0 1 0 -20 0.1 -19.5 -20.1 02/10/2005 14:20:00 7.5 0.6 9.5 5.7 7.3 0.7 9.9 4.9 0.4 0 0.4 0.4 216 5 213 305 1 0 1 0 -19.7 0.1 -19.2 -19.9 02/10/2005 14:30:00 7.4 0.6 9.1 5.7 7.2 0.8 9.1 4.9 0.4 0 0.4 0.4 213 5 212 305 2 0 1 0 -19.3 0.2 -18.8 -19.7 02/10/2005 14:40:00 7.2 0.5 8.4 5.3 7 0.7 8.4 4.6 0.4 0 0.4 0.4 214 5 221 305 2 0 2 0 -19.3 0.2 -18.8 -19.7 02/10/2005 14:50:00 6.7 0.6 8.4 4.9 6.4 0.8 8.4 4.6 0.4 0 0.4 0.4 217 4 220 305 1 0 1 0 -19.6 0.1 -19 -19.9 02/10/2005 15:00:00 6.7 0.5 7.6 4.9 6.6 0.6 7.6 4.9 0.4 0 0.4 0.4 216 4 218 305 1 0 1 0 -19.7 0.1 -19.3 -19.9 02/10/2005 15:10:00 6.8 0.6 8 5.3 6.5 0.7 8 4.6 0.4 0 0.4 0.4 215 4 217 305 1 0 1 0 -19.6 0 -19.2 -19.9 02/10/2005 15:20:00 6.9 0.5 8 5.3 6.7 0.6 8 4.9 0.4 0 0.4 0.4 214 4 215 305 1 0 1 0 -19.7 0.1 -19.3 -19.9 02/10/2005 15:30:00 6.2 0.6 7.2 4.2 6.1 0.6 7.2 4.2 0.4 0 0.4 0.4 214 5 208 305 1 0 1 0 -19.7 0.1 -19.3 -20.1 02/10/2005 15:40:00 6.1 0.4 6.8 4.9 6 0.5 6.8 4.6 0.4 0 0.4 0.4 213 5 217 305 1 0 1 0 -19.8 0.1 -19.5 -20.1 02/10/2005 15:50:00 5.9 0.6 7.2 4.2 5.7 0.7 7.2 3.8 0.4 0 0.4 0.4 218 3 217 305 1 0 1 0 -20.1 0.1 -19.5 -20.2 02/10/2005 16:00:00 5.4 0.6 6.8 3.8 5.3 0.6 6.8 3.8 0.4 0 0.4 0.4 213 5 208 305 1 0 1 0 -19.7 0.1 -19.3 -20.1 02/10/2005 16:10:00 5.3 0.5 6.5 3.8 5.1 0.6 6.5 3.4 0.4 0 0.4 0.4 219 4 219 305 1 0 1 0 -19.7 0.1 -19.2 -19.9 02/10/2005 16:20:00 5.2 0.6 6.5 3 5.1 0.6 6.5 3.4 0.4 0 0.4 0.4 213 4 217 305 1 0 1 0 -19.7 0.1 -19.3 -19.9 02/10/2005 16:30:00 5.5 0.4 6.5 4.6 5.5 0.4 6.5 4.6 0.4 0 0.4 0.4 209 4 214 305 1 0 1 0 -19.9 0.1 -19.5 -20.1 02/10/2005 16:40:00 5.6 0.4 6.5 4.6 5.6 0.4 6.5 4.6 0.4 0 0.4 0.4 208 3 208 305 1 0 1 0 -19.9 0 -19.5 -20.1 02/10/2005 16:50:00 5.6 0.5 6.8 4.2 5.6 0.6 6.8 3.8 0.4 0 0.4 0.4 209 4 202 305 1 0 1 0 -20 0.1 -19.5 -20.1 02/10/2005 17:00:00 5.4 0.4 6.1 4.6 5.4 0.4 6.5 4.2 0.4 0 0.4 0.4 209 3 208 305 1 0 1 0 -20.2 0.1 -19.5 -20.4 02/10/2005 17:10:00 5.3 0.6 6.5 3 5.2 0.7 6.8 2.6 0.4 0 0.4 0.4 211 4 208 305 1 0 1 0 -20.2 0 -19.9 -20.6 02/10/2005 17:20:00 4.3 0.5 6.1 3.4 4.3 0.4 5.3 3.4 0.4 0 0.4 0.4 207 8 219 305 1 0 1 0 -20.7 0.2 -20.1 -21 02/10/2005 17:30:00 4.5 0.6 6.1 3 4.8 0.7 6.8 3 0.4 0 0.4 0.4 191 8 193 305 1 0 1 0 -20.9 0.1 -20.4 -21 02/10/2005 17:40:00 5.1 0.5 6.5 3.8 5.3 0.5 6.8 3.8 0.4 0 0.4 0.4 192 6 196 305 1 0 1 0 -21 0.2 -20.4 -21.3 02/10/2005 17:50:00 4.5 0.7 6.1 2.3 4.9 0.6 6.5 2.6 0.4 0 0.4 0.4 187 7 192 305 1 0 1 0 -21.2 0.1 -20.8 -21.3 02/10/2005 18:00:00 3.9 0.8 6.1 1.9 4.5 0.6 6.8 3 0.4 0 0.4 0.4 184 9 182 305 1 0 1 0 -21.2 0 -20.8 -21.3 02/10/2005 18:10:00 4.4 0.5 5.7 3.4 4.5 0.5 5.7 3 0.4 0 0.4 0.4 192 6 203 305 1 0 1 0 -21.4 0.1 -21.1 -21.7 02/10/2005 18:20:00 3.6 0.4 4.9 2.3 3.7 0.4 4.9 2.3 0.4 0 0.4 0.4 194 7 197 305 1 0 1 0 -21.7 0 -21.5 -21.8 02/10/2005 18:30:00 4.5 0.7 6.1 2.6 4.2 0.6 5.7 2.6 0.4 0 0.4 0.4 215 15 224 305 1 0 1 0 -21.7 0.1 -21.3 -21.8 02/10/2005 18:40:00 5.3 0.5 6.5 4.2 4.9 0.5 5.7 3.8 0.4 0 0.4 0.4 229 3 228 305 1 0 0 0 -21.3 0 -21.1 -21.3 02/10/2005 18:50:00 5.2 0.4 6.1 4.2 4.7 0.4 6.1 3.8 0.4 0 0.4 0.4 231 3 235 305 1 0 1 0 -21.3 0 -21.1 -21.3 02/10/2005 19:00:00 4.9 0.4 6.1 4.2 4.6 0.4 5.7 3.8 0.4 0 0.4 0.4 228 4 228 305 1 0 1 0 -21.3 0 -21.1 -21.3 02/10/2005 19:10:00 4.6 0.4 5.3 3.4 4.2 0.5 5.3 2.6 0.4 0 0.4 0.4 222 5 224 305 1 0 1 0 -21.5 0.1 -21.3 -21.7 02/10/2005 19:20:00 4.2 0.4 5.3 2.6 3.8 0.4 4.9 2.3 0.4 0 0.4 0.4 221 5 227 305 1 0 1 0 -21.9 0.1 -21.5 -22.2 02/10/2005 19:30:00 3.5 0.4 4.6 2.6 3.6 0.4 4.6 2.6 0.4 0 0.4 0.4 207 9 217 305 1 0 1 0 -22.1 0 -21.8 -22.4 02/10/2005 19:40:00 3.4 0.4 4.6 2.6 3.5 0.4 4.6 1.9 0.4 0 0.4 0.4 198 6 204 305 1 0 1 0 -22 0 -21.8 -22.2 02/10/2005 19:50:00 3.2 0.3 3.8 2.3 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 200 7 203 305 1 0 1 0 -22.1 0 -21.8 -22.4 02/10/2005 20:00:00 3.4 0.3 4.2 2.6 3.2 0.3 4.2 2.3 0.4 0 0.4 0.4 212 9 216 305 1 0 1 0 -22.3 0 -22.2 -22.4 02/10/2005 20:10:00 3.7 0.5 4.9 2.6 3.2 0.4 4.6 2.3 0.4 0 0.4 0.4 219 9 221 305 1 0 1 0 -22.4 0 -22.2 -22.5 02/10/2005 20:20:00 3.4 0.4 4.2 2.3 3.4 0.4 4.6 2.3 0.4 0 0.4 0.4 210 7 213 305 1 0 1 0 -22.3 0 -22 -22.5 02/10/2005 20:30:00 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.6 0.4 0 0.4 0.4 210 9 224 305 1 0 1 0 -22.3 0 -22 -22.5 02/10/2005 20:40:00 3.2 0.4 4.2 2.3 3.2 0.3 4.2 2.3 0.4 0 0.4 0.4 208 9 201 305 1 0 1 0 -22.4 0 -22.2 -22.5 02/10/2005 20:50:00 3.9 0.5 5.3 2.6 3.5 0.4 4.6 2.6 0.4 0 0.4 0.4 220 8 225 305 1 0 1 0 -22.5 0.1 -22.4 -22.9 02/10/2005 21:00:00 3.6 0.3 4.6 2.6 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 216 6 216 305 1 0 1 0 -22.7 0.1 -22.5 -22.9 02/10/2005 21:10:00 3.8 0.4 4.9 2.6 3.7 0.3 4.6 3 0.4 0 0.4 0.4 217 6 210 305 1 0 1 0 -22.5 0.1 -22.4 -22.7 02/10/2005 21:20:00 3.3 0.4 4.2 2.3 3.3 0.3 4.6 2.6 0.4 0 0.4 0.4 209 8 205 305 1 0 1 0 -22.5 0.1 -22.4 -22.7 02/10/2005 21:30:00 3.3 0.4 4.6 2.3 3.3 0.4 4.2 2.3 0.4 0 0.4 0.4 209 8 216 305 1 0 1 0 -22.5 0 -22.4 -22.5 02/10/2005 21:40:00 2.9 0.4 3.8 1.9 3 0.4 4.6 2.3 0.4 0 0.4 0.4 205 7 211 305 1 0 1 0 -22.6 0.1 -22.4 -22.9 02/10/2005 21:50:00 2.8 0.4 3.8 1.9 3.1 0.3 4.2 2.3 0.4 0 0.4 0.4 197 7 195 305 1 0 1 0 -22.7 0.1 -22.5 -22.9 02/10/2005 22:00:00 2.7 0.4 3.8 1.5 2.9 0.4 4.2 1.9 0.4 0 0.4 0.4 198 7 196 305 1 0 1 0 -22.6 0 -22 -22.7 02/10/2005 22:10:00 3.1 0.4 3.8 2.3 3.2 0.3 3.8 2.6 0.4 0 0.4 0.4 198 5 199 305 1 0 1 0 -22.6 0.1 -22.4 -22.9 02/10/2005 22:20:00 3.3 0.3 4.2 2.6 3.5 0.3 4.2 3 0.4 0 0.4 0.4 200 5 205 305 1 0 1 0 -22.6 0.1 -22.4 -22.7 02/10/2005 22:30:00 3.3 0.3 4.2 2.6 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 203 3 205 305 1 0 1 0 -22.5 0 -22.4 -22.5 02/10/2005 22:40:00 3.9 0.2 4.6 3.4 4.1 0.2 4.6 3.4 0.4 0 0.4 0.4 198 3 194 305 1 0 1 0 -22.7 0.1 -22.4 -23 02/10/2005 22:50:00 4.1 0.3 4.9 3.4 4.2 0.3 4.9 3.8 0.4 0 0.4 0.4 197 4 197 305 1 0 1 0 -22.8 0 -22.5 -22.9 02/10/2005 23:00:00 3.8 0.3 4.6 3 4 0.3 4.6 3.4 0.4 0 0.4 0.4 195 5 206 305 1 0 1 0 -22.8 0 -22.2 -22.9 02/10/2005 23:10:00 3.7 0.3 4.6 3 3.9 0.3 4.6 3.4 0.4 0 0.4 0.4 197 5 203 305 1 0 0 0 -22.8 0 -22.5 -23 02/10/2005 23:20:00 3.6 0.3 4.6 3 3.8 0.3 4.6 2.6 0.4 0 0.4 0.4 196 5 199 305 1 0 1 0 -22.9 0 -22.7 -23 02/10/2005 23:30:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 199 5 205 305 0 0 1 0 -22.7 0.1 -22.5 -22.9 02/10/2005 23:40:00 3.4 0.3 4.2 2.6 3.7 0.3 4.9 2.6 0.4 0 0.4 0.4 203 5 205 305 0 0 0 0 -22.5 0 -22.5 -22.7 02/10/2005 23:50:00 3.8 0.3 4.6 3 4 0.3 4.6 3.4 0.4 0 0.4 0.4 205 5 202 305 0 0 1 0 -22.6 0.1 -22.4 -22.9 02/11/2005 00:00:00 3.9 0.3 4.6 3.4 4.1 0.3 4.6 3.4 0.4 0 0.4 0.4 200 5 197 305 1 0 1 0 -22.8 0 -22.4 -23 02/11/2005 00:10:00 3.8 0.3 4.6 2.6 3.9 0.3 4.9 3 0.4 0 0.4 0.4 195 5 199 305 1 0 0 0 -23 0 -22.9 -23.2 02/11/2005 00:20:00 3.6 0.3 4.6 2.6 3.7 0.3 4.6 3 0.4 0 0.4 0.4 193 5 199 305 1 0 0 0 -23 0 -22.5 -23.2 02/11/2005 00:30:00 3.8 0.3 4.6 3 4.1 0.3 4.9 3.4 0.4 0 0.4 0.4 193 4 194 305 1 0 0 0 -22.8 0.1 -22.5 -23 02/11/2005 00:40:00 3.7 0.2 4.6 3 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 191 3 190 305 1 0 1 0 -22.9 0 -22.7 -23 02/11/2005 00:50:00 3.9 0.3 4.6 3 4.1 0.2 4.6 3.4 0.4 0 0.4 0.4 191 3 194 305 1 0 1 0 -22.9 0 -22.2 -23 02/11/2005 01:00:00 4 0.2 4.6 3.4 4.2 0.3 4.9 3.4 0.4 0 0.4 0.4 191 4 190 305 1 0 1 0 -22.8 0.1 -22.2 -23 02/11/2005 01:10:00 3.9 0.3 4.6 3 4.1 0.3 4.6 3.4 0.4 0 0.4 0.4 196 4 190 305 1 0 1 0 -22.8 0 -22.5 -23 02/11/2005 01:20:00 3.7 0.2 4.2 3 3.8 0.2 4.6 3.4 0.4 0 0.4 0.4 200 4 198 305 1 0 1 0 -22.8 0.1 -22.5 -23 02/11/2005 01:30:00 3.8 0.2 4.6 3 4.1 0.2 4.6 3.4 0.4 0 0.4 0.4 201 3 203 305 1 0 0 0 -23.2 0.1 -22.9 -23.4 02/11/2005 01:40:00 3.9 0.2 4.6 3.4 4.1 0.2 4.6 3.4 0.4 0 0.4 0.4 200 3 200 305 1 0 1 0 -23 0 -22.7 -23.2 02/11/2005 01:50:00 3.9 0.2 4.6 3.4 4.1 0.2 4.6 3.4 0.4 0 0.4 0.4 200 3 205 305 1 0 1 0 -22.8 0 -22.5 -22.9 02/11/2005 02:00:00 3.8 0.2 4.2 3 4 0.2 4.9 3.4 0.4 0 0.4 0.4 198 4 194 305 1 0 1 0 -22.8 0.1 -22.2 -23 02/11/2005 02:10:00 3.9 0.2 4.6 3.4 4.1 0.2 4.6 3.4 0.4 0 0.4 0.4 199 3 203 305 1 0 1 0 -22.9 0 -22.7 -23 02/11/2005 02:20:00 3.9 0.2 4.6 3.4 4.1 0.3 4.9 3.4 0.4 0 0.4 0.4 199 3 198 305 1 0 1 0 -22.8 0.1 -22.2 -22.9 02/11/2005 02:30:00 3.8 0.2 4.2 3.4 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 200 3 198 305 1 0 1 0 -22.8 0 -22.5 -22.9 02/11/2005 02:40:00 3.7 0.2 4.2 3 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 203 4 199 305 1 0 1 0 -22.9 0 -22.4 -23.2 02/11/2005 02:50:00 3.7 0.3 4.6 2.6 3.9 0.3 4.6 3 0.4 0 0.4 0.4 201 4 203 305 1 0 1 0 -22.9 0 -22.5 -23 02/11/2005 03:00:00 3.6 0.3 4.6 2.6 3.8 0.3 4.6 3 0.4 0 0.4 0.4 198 5 198 305 1 0 0 0 -22.8 0 -22.5 -23 02/11/2005 03:10:00 3.5 0.3 4.2 2.6 3.6 0.3 4.9 3 0.4 0 0.4 0.4 200 5 198 305 1 0 1 0 -22.7 0.1 -22.5 -22.9 02/11/2005 03:20:00 3.5 0.3 4.6 2.6 3.6 0.3 4.6 3 0.4 0 0.4 0.4 202 6 209 305 1 0 1 0 -22.8 0 -22.4 -23 02/11/2005 03:30:00 3.4 0.3 4.2 2.6 3.6 0.3 4.2 2.6 0.4 0 0.4 0.4 201 4 196 305 1 0 1 0 -22.8 0 -22.5 -23 02/11/2005 03:40:00 3.2 0.3 3.8 2.6 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 196 5 203 305 1 0 1 0 -22.7 0.1 -22.2 -23 02/11/2005 03:50:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 3 0.4 0 0.4 0.4 198 6 190 305 1 0 1 0 -22.8 0.2 -22.5 -23.2 02/11/2005 04:00:00 3.3 0.3 3.8 2.6 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 197 5 197 305 1 0 1 0 -22.6 0 -22.2 -22.7 02/11/2005 04:10:00 3.2 0.3 3.8 2.3 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 192 5 201 305 1 0 1 0 -22.9 0.1 -22.5 -23.2 02/11/2005 04:20:00 3.5 0.3 4.2 2.6 3.6 0.3 4.2 2.6 0.4 0 0.4 0.4 193 4 193 305 1 0 1 0 -22.9 0 -22.9 -23.2 02/11/2005 04:30:00 3.5 0.3 4.2 2.6 3.7 0.3 4.6 2.6 0.4 0 0.4 0.4 192 5 195 305 1 0 1 0 -23.2 0.1 -22.9 -23.4 02/11/2005 04:40:00 3.7 0.3 4.6 2.6 3.8 0.3 4.6 3 0.4 0 0.4 0.4 195 5 195 305 1 0 1 0 -23 0.1 -22.7 -23.4 02/11/2005 04:50:00 3.9 0.2 4.6 3.4 4.1 0.3 4.6 3.4 0.4 0 0.4 0.4 196 4 192 305 1 0 1 0 -22.9 0 -22.5 -23.2 02/11/2005 05:00:00 3.8 0.3 4.6 3 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 197 4 196 305 1 0 1 0 -22.9 0 -22.2 -23 02/11/2005 05:10:00 3.7 0.3 4.2 3 3.9 0.3 4.6 3 0.4 0 0.4 0.4 197 4 204 305 1 0 1 0 -23 0.1 -22.9 -23.2 02/11/2005 05:20:00 3.7 0.2 4.2 3 3.9 0.2 4.6 3 0.4 0 0.4 0.4 196 4 201 305 1 0 1 0 -23.3 0 -23.2 -23.4 02/11/2005 05:30:00 3.5 0.3 4.2 2.6 3.7 0.2 4.6 3 0.4 0 0.4 0.4 195 5 195 305 1 0 1 0 -23.3 0.1 -23 -23.4 02/11/2005 05:40:00 3.7 0.3 4.6 3 3.9 0.3 4.9 3.4 0.4 0 0.4 0.4 194 4 197 305 1 0 1 0 -23.4 0.1 -23 -23.7 02/11/2005 05:50:00 3.6 0.3 4.2 3 3.9 0.2 4.6 3 0.4 0 0.4 0.4 193 4 193 305 1 0 1 0 -23.5 0 -22.9 -23.7 02/11/2005 06:00:00 3.4 0.2 4.2 2.6 3.8 0.2 4.6 3 0.4 0 0.4 0.4 189 4 193 305 1 0 1 0 -23.8 0.2 -23.4 -24.2 02/11/2005 06:10:00 3.4 0.3 4.2 2.6 3.8 0.2 4.6 3 0.4 0 0.4 0.4 188 4 190 305 1 0 1 0 -24.1 0.1 -23.6 -24.4 02/11/2005 06:20:00 3.1 0.2 3.8 2.3 3.4 0.3 4.2 2.3 0.4 0 0.4 0.4 191 3 193 305 0 0 0 0 -24 0.2 -23.2 -24.2 02/11/2005 06:30:00 3.1 0.3 3.8 2.3 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 193 5 187 305 1 0 0 0 -23.6 0.1 -23.2 -23.9 02/11/2005 06:40:00 3.1 0.3 3.8 2.3 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 194 6 189 305 1 0 0 0 -23.3 0.2 -22.7 -23.9 02/11/2005 06:50:00 3 0.3 3.4 1.9 3.3 0.3 4.2 2.6 0.4 0 0.4 0.4 194 5 192 305 1 0 1 0 -23.3 0.3 -22.9 -23.9 02/11/2005 07:00:00 3 0.3 3.8 1.9 3.3 0.3 4.2 2.6 0.4 0 0.4 0.4 195 5 196 305 1 0 1 0 -23.5 0 -23.2 -23.7 02/11/2005 07:10:00 3.1 0.3 3.8 2.6 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 195 4 191 305 1 0 1 0 -23.2 0 -23 -23.4 02/11/2005 07:20:00 3 0.3 3.8 1.9 3.3 0.3 3.8 2.3 0.4 0 0.4 0.4 195 5 195 305 1 0 1 0 -23.4 0.1 -23.2 -23.7 02/11/2005 07:30:00 3.1 0.2 3.8 2.6 3.4 0.2 3.8 2.6 0.4 0 0.4 0.4 196 4 189 305 1 0 1 0 -23.3 0.1 -23 -23.4 02/11/2005 07:40:00 3.1 0.2 3.8 2.3 3.4 0.2 3.8 2.6 0.4 0 0.4 0.4 192 5 191 305 1 0 1 0 -23.7 0.2 -23.2 -23.9 02/11/2005 07:50:00 3.2 0.3 4.2 2.6 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 194 5 192 305 1 0 1 0 -23.3 0.1 -23 -23.6 02/11/2005 08:00:00 3.1 0.3 3.8 2.3 3.4 0.2 4.2 2.6 0.4 0 0.4 0.4 188 4 192 305 1 0 1 0 -23.9 0.3 -23 -24.2 02/11/2005 08:10:00 2.9 0.4 3.8 1.9 3.2 0.3 4.2 2.6 0.4 0 0.4 0.4 186 4 196 305 0 0 0 0 -24.5 0.3 -23.9 -24.7 02/11/2005 08:20:00 2.6 0.4 3.8 1.5 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 184 5 191 305 0 0 0 0 -24.4 0.1 -23.9 -24.6 02/11/2005 08:30:00 2.7 0.5 3.8 1.5 3.4 0.3 4.6 2.6 0.4 0 0.4 0.4 181 5 186 305 1 0 1 0 -24.2 0.2 -23.6 -24.6 02/11/2005 08:40:00 2.7 0.5 3.4 1.1 3.3 0.3 4.2 2.3 0.4 0 0.4 0.4 182 5 180 305 1 0 0 0 -24.4 0.2 -23.6 -24.9 02/11/2005 08:50:00 3 0.3 3.8 1.9 3.4 0.2 4.2 2.6 0.4 0 0.4 0.4 185 4 183 305 0 0 0 0 -24.7 0.1 -24.2 -24.9 02/11/2005 09:00:00 2.8 0.4 3.4 1.5 3.3 0.3 3.8 2.6 0.4 0 0.4 0.4 183 4 178 305 0 0 0 0 -25.1 0.3 -24.6 -25.6 02/11/2005 09:10:00 2.8 0.3 3.4 1.9 3.3 0.2 3.8 2.6 0.4 0 0.4 0.4 184 4 188 305 0 0 0 0 -25.4 0.1 -24.9 -25.6 02/11/2005 09:20:00 2.5 0.5 3.8 1.1 3.2 0.3 3.8 2.3 0.4 0 0.4 0.4 181 5 180 305 0 0 0 0 -25.4 0.2 -24.7 -25.6 02/11/2005 09:30:00 2.7 0.5 3.8 1.5 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 180 5 179 305 0 0 0 0 -25 0.2 -24.2 -25.2 02/11/2005 09:40:00 2.6 0.5 4.2 1.5 3.5 0.3 4.6 2.6 0.4 0 0.4 0.4 176 8 192 305 1 0 1 0 -24.5 0.1 -23.9 -24.6 02/11/2005 09:50:00 2.5 0.5 3.8 1.1 3.2 0.4 4.2 2.3 0.4 0 0.4 0.4 180 6 188 305 1 0 1 0 -24.2 0 -23.9 -24.6 02/11/2005 10:00:00 2.6 0.5 3.8 1.5 3.3 0.3 4.2 2.3 0.4 0 0.4 0.4 181 5 186 305 0 0 0 0 -24.7 0.1 -23.9 -24.9 02/11/2005 10:10:00 2.4 0.5 4.2 1.1 3.4 0.3 4.2 2.3 0.4 0 0.4 0.4 180 6 183 305 0 0 0 0 -24.9 0.1 -24.4 -25.1 02/11/2005 10:20:00 2.2 0.5 3.4 1.1 3.3 0.3 4.2 2.3 0.4 0 0.4 0.4 176 8 162 305 1 0 0 0 -24.2 0.3 -23.6 -24.7 02/11/2005 10:30:00 2.1 0.5 3.4 1.1 3.3 0.4 4.2 2.3 0.4 0 0.4 0.4 168 7 159 305 1 0 1 0 -24.6 0.2 -23.9 -24.7 02/11/2005 10:40:00 2 0.5 3.4 1.1 3.2 0.5 4.6 1.9 0.4 0 0.4 0.4 175 8 165 305 1 0 1 0 -24.5 0.1 -23.9 -24.9 02/11/2005 10:50:00 2.6 0.4 3.4 1.1 3.1 0.3 4.2 2.3 0.4 0 0.4 0.4 183 4 182 305 0 0 0 0 -24.7 0.1 -24.1 -25.1 02/11/2005 11:00:00 2.7 0.3 3.4 1.9 3.2 0.2 3.8 2.6 0.4 0 0.4 0.4 184 3 184 305 0 0 0 0 -25.1 0.1 -24.6 -25.2 02/11/2005 11:10:00 2.6 0.4 3.4 1.5 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 184 4 192 305 0 0 0 0 -25.1 0.3 -24.2 -25.6 02/11/2005 11:20:00 2.5 0.4 3.4 1.5 3 0.3 3.4 2.3 0.4 0 0.4 0.4 183 4 184 305 0 0 0 0 -24.3 0.1 -23.9 -24.6 02/11/2005 11:30:00 1.8 0.4 3 0.7 3 0.3 3.8 1.9 0.4 0 0.4 0.4 174 6 184 305 1 0 0 0 -24.3 0.2 -23.6 -24.6 02/11/2005 11:40:00 1.4 0.4 2.3 0.7 2.3 0.4 3.4 1.5 0.4 0 0.4 0.4 174 7 181 305 0 0 0 0 -24.5 0.1 -23.9 -24.6 02/11/2005 11:50:00 1 0.3 1.9 0.4 2 0.2 2.6 1.5 0.4 0 0.4 0.4 175 4 181 305 0 0 0 0 -24.5 0.1 -23.9 -24.6 02/11/2005 12:00:00 1.4 0.5 2.6 0.4 2.1 0.3 3 1.5 0.4 0 0.4 0.4 167 7 154 305 1 0 1 0 -24 0.2 -23.4 -24.4 02/11/2005 12:10:00 1.8 0.4 3 0.7 2.3 0.3 3.4 1.9 0.4 0 0.4 0.4 159 6 152 305 1 0 1 0 -23.9 0 -23.7 -23.9 02/11/2005 12:20:00 1.7 0.4 2.6 0.7 2.1 0.2 3 1.5 0.4 0 0.4 0.4 164 6 158 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 02/11/2005 12:30:00 1.7 0.4 2.6 0.7 2.2 0.2 2.6 1.5 0.4 0 0.4 0.4 167 8 155 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 02/11/2005 12:40:00 1.8 0.4 2.6 0.7 2.1 0.2 2.6 1.5 0.4 0 0.4 0.4 160 5 159 305 1 0 1 0 -23 0.4 -22.4 -23.6 02/11/2005 12:50:00 2.3 0.2 3 1.5 2.3 0.2 3 1.9 0.4 0 0.4 0.4 153 2 152 305 1 0 1 0 -22.2 0.1 -21.8 -22.5 02/11/2005 13:00:00 2.8 0.5 3.8 1.5 2.9 0.4 3.4 1.9 0.4 0 0.4 0.4 153 4 150 305 1 0 1 0 -22.1 0.2 -21.8 -22.5 02/11/2005 13:10:00 3.5 0.3 4.2 3 3.4 0.2 3.8 3 0.4 0 0.4 0.4 147 2 146 305 1 0 1 0 -22.5 0.1 -22.2 -22.7 02/11/2005 13:20:00 3.7 0.2 4.2 3.4 3.6 0.2 4.2 3 0.4 0 0.4 0.4 146 2 148 305 1 0 1 0 -22 0.1 -21.8 -22.4 02/11/2005 13:30:00 4.1 0.2 4.6 3.4 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 150 4 144 305 1 0 1 0 -22.1 0.1 -21.8 -22.4 02/11/2005 13:40:00 4.1 0.4 4.9 2.3 4.1 0.2 4.6 3.8 0.4 0 0.4 0.4 157 3 155 305 1 0 0 0 -22.2 0.1 -21.8 -22.4 02/11/2005 13:50:00 4.3 0.2 4.9 3.4 4.3 0.2 4.9 3.8 0.4 0 0.4 0.4 153 2 152 305 1 0 1 0 -21.7 0.1 -21.5 -22 02/11/2005 14:00:00 4.5 0.2 4.9 4.2 4.5 0.2 4.9 4.2 0.4 0 0.4 0.4 149 2 152 305 1 0 1 0 -21.5 0 -21.3 -21.7 02/11/2005 14:10:00 4.5 0.2 4.9 4.2 4.5 0.2 4.9 4.2 0.4 0 0.4 0.4 143 2 144 305 1 0 1 0 -21.3 0 -21.3 -21.7 02/11/2005 14:20:00 4.6 0.2 4.9 4.2 4.6 0.2 4.9 4.2 0.4 0 0.4 0.4 145 2 145 305 1 0 1 0 -21.3 0 -21.3 -21.5 02/11/2005 14:30:00 4.7 0.2 5.3 4.2 4.7 0.2 5.3 4.2 0.4 0 0.4 0.4 147 2 144 305 1 0 1 0 -21.5 0.1 -21.3 -21.8 02/11/2005 14:40:00 4.8 0.2 5.3 4.2 4.8 0.2 5.3 4.6 0.4 0 0.4 0.4 146 2 143 305 1 0 1 0 -21.7 0 -21.5 -21.8 02/11/2005 14:50:00 4.9 0.4 5.7 2.6 5.1 0.3 5.7 3.8 0.4 0 0.4 0.4 150 4 152 305 1 0 1 0 -21.8 0.1 -21.5 -22.2 02/11/2005 15:00:00 4.2 0.8 5.7 2.3 5.1 0.3 6.1 4.2 0.4 0 0.4 0.4 160 6 157 305 0 0 0 0 -22.4 0.2 -22 -22.9 02/11/2005 15:10:00 2.9 0.5 4.6 1.9 4.6 0.4 5.7 3.8 0.4 0 0.4 0.4 169 6 169 305 0 0 0 0 -23 0.1 -22.7 -23.2 02/11/2005 15:20:00 2.8 0.4 4.2 1.9 4.5 0.3 5.3 3.8 0.4 0 0.4 0.4 170 6 184 305 0 0 0 0 -22.8 0.2 -22.5 -23.2 02/11/2005 15:30:00 2.8 0.5 4.6 1.5 4.4 0.4 5.3 3.4 0.4 0 0.4 0.4 168 5 161 305 0 0 0 0 -22.5 0 -22.4 -22.7 02/11/2005 15:40:00 2.7 0.5 4.2 1.9 4 0.4 4.9 3 0.4 0 0.4 0.4 174 7 186 305 0 0 1 0 -22.4 0 -22.2 -22.5 02/11/2005 15:50:00 2.6 0.5 3.8 1.5 3.7 0.3 4.6 3 0.4 0 0.4 0.4 177 7 186 305 0 0 0 0 -22.4 0.1 -22 -22.7 02/11/2005 16:00:00 2.6 0.5 3.8 1.5 3.8 0.4 4.9 2.6 0.4 0 0.4 0.4 172 7 183 305 0 0 0 0 -22.8 0 -22.5 -23 02/11/2005 16:10:00 2.6 0.5 3.8 1.5 4 0.4 4.9 2.6 0.4 0 0.4 0.4 175 6 182 305 0 0 0 0 -22.9 0 -22.9 -23.2 02/11/2005 16:20:00 2.4 0.5 3.8 1.1 3.8 0.4 4.6 2.6 0.4 0 0.4 0.4 170 7 163 305 0 0 0 0 -22.8 0.1 -22.5 -23 02/11/2005 16:30:00 2.3 0.4 3.8 1.5 3.7 0.3 4.6 3 0.4 0 0.4 0.4 171 6 152 305 1 0 1 0 -22.4 0 -22.2 -22.5 02/11/2005 16:40:00 2 0.4 3 1.1 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 173 5 179 305 1 0 0 0 -22.1 0 -21.8 -22.4 02/11/2005 16:50:00 2 0.4 3 1.1 3.3 0.3 4.2 2.6 0.4 0 0.4 0.4 170 5 169 305 1 0 1 0 -22.2 0.1 -21.8 -22.4 02/11/2005 17:00:00 1.9 0.5 3.4 0.7 2.8 0.5 4.2 1.9 0.4 0 0.4 0.4 168 8 160 305 1 0 1 0 -22 0.2 -21.7 -22.5 02/11/2005 17:10:00 1.7 0.4 3 0.7 2.5 0.3 3.4 1.5 0.4 0 0.4 0.4 172 7 166 305 0 0 0 0 -22.7 0.1 -22.5 -23 02/11/2005 17:20:00 2.7 0.2 3.4 1.5 2.9 0.2 3.4 2.6 0.4 0 0.4 0.4 151 3 150 305 1 0 0 0 -23 0 -22.7 -23.2 02/11/2005 17:30:00 2.2 0.6 3 1.1 2.5 0.3 3 1.9 0.4 0 0.4 0.4 159 3 152 305 0 0 1 0 -22.7 0 -22.5 -22.9 02/11/2005 17:40:00 1.5 0.5 2.6 0.7 2.2 0.3 2.6 1.5 0.4 0 0.4 0.4 165 5 161 305 0 0 0 0 -23 0.2 -22.5 -23.4 02/11/2005 17:50:00 1.7 0.3 2.3 1.1 1.9 0.4 2.6 1.1 0.4 0 0.4 0.4 154 0 155 305 0 0 0 0 -23 0.1 -22.9 -23.2 02/11/2005 18:00:00 1.4 0.2 1.9 1.1 1.5 0.2 1.9 1.1 0.4 0 0.4 0.4 146 7 141 305 0 0 0 0 -23.3 0.2 -22.9 -23.9 02/11/2005 18:10:00 0.9 0.5 1.9 0.4 1.3 0.4 1.9 0.4 0.4 0 0.4 0.4 124 7 136 305 1 0 1 0 -23.4 0.1 -23.2 -23.7 02/11/2005 18:20:00 1.5 0.5 2.6 0.4 1.8 0.5 3 0.7 0.4 0 0.4 0.4 120 7 133 305 1 0 1 0 -23.4 0 -23.2 -23.6 02/11/2005 18:30:00 3 0.6 4.2 1.5 3.2 0.6 4.2 1.5 0.4 0 0.4 0.4 129 4 133 305 1 0 1 0 -23.3 0.1 -23.2 -23.6 02/11/2005 18:40:00 4 0.2 4.6 3.4 4.1 0.2 4.6 3.8 0.4 0 0.4 0.4 132 1 134 305 1 0 1 0 -23.5 0 -23.4 -23.7 02/11/2005 18:50:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3.4 0.4 0 0.4 0.4 128 3 130 305 1 0 1 0 -23.5 0 -23.2 -23.7 02/11/2005 19:00:00 4.1 0.2 4.6 3.8 4.1 0.2 4.6 3.4 0.4 0 0.4 0.4 128 2 129 305 1 0 1 0 -23.3 0.1 -22.9 -23.4 02/11/2005 19:10:00 3.3 0.5 4.6 2.6 3.3 0.4 4.6 2.6 0.4 0 0.4 0.4 127 3 124 305 1 0 1 0 -23.2 0.1 -23 -23.4 02/11/2005 19:20:00 3.5 0.8 5.3 2.3 3.3 0.7 4.9 2.3 0.4 0 0.4 0.4 113 4 112 305 1 0 1 0 -23.5 0.1 -23.2 -23.9 02/11/2005 19:30:00 3.9 0.6 4.6 2.6 3.8 0.5 4.6 2.3 0.4 0 0.4 0.4 106 3 109 305 1 0 1 0 -23.5 0 -23.4 -23.9 02/11/2005 19:40:00 4.5 0.4 5.3 3.8 4.3 0.4 5.3 3.4 0.4 0 0.4 0.4 105 3 104 305 1 0 1 0 -23.8 0.1 -23.6 -24.1 02/11/2005 19:50:00 4.8 0.4 5.7 3.8 4.5 0.3 5.3 3.8 0.4 0 0.4 0.4 103 2 102 305 1 0 0 0 -23.9 0 -23.7 -24.1 02/11/2005 20:00:00 4.7 0.3 6.5 3.4 4.4 0.3 5.7 3.8 0.4 0 0.4 0.4 101 5 105 305 1 0 1 0 -23.8 0.1 -23.6 -23.9 02/11/2005 20:10:00 4.6 0.5 5.3 3 4.4 0.4 4.9 3 0.4 0 0.4 0.4 96 4 96 305 1 0 1 0 -23.7 0.1 -23.2 -23.9 02/11/2005 20:20:00 4.6 0.4 5.3 3.4 4.3 0.4 5.3 3.4 0.4 0 0.4 0.4 98 5 98 305 1 0 1 0 -23.3 0.1 -23 -23.4 02/11/2005 20:30:00 5.3 0.4 6.5 4.6 5 0.4 5.7 4.2 0.4 0 0.4 0.4 99 3 98 305 1 0 1 0 -22.8 0.1 -22.4 -23.2 02/11/2005 20:40:00 5.9 0.3 6.5 4.9 5.6 0.3 6.8 4.9 0.4 0 0.4 0.4 100 3 98 305 1 0 1 0 -22.3 0.1 -21.8 -22.5 02/11/2005 20:50:00 5.3 0.7 6.8 3.4 5 0.7 6.8 2.6 0.4 0 0.4 0.4 97 8 112 305 1 0 1 0 -21.6 0.1 -21.3 -22 02/11/2005 21:00:00 5.5 0.8 7.6 3.4 5 0.7 7.6 3.4 0.4 0 0.4 0.4 86 9 78 305 1 0 1 0 -21.3 0 -21.3 -21.5 02/11/2005 21:10:00 6.6 0.7 8.4 4.9 6.1 0.7 8 4.2 0.4 0 0.4 0.4 75 7 71 305 1 0 1 0 -21.2 0 -21 -21.3 02/11/2005 21:20:00 6.8 0.9 9.1 4.9 6.4 0.9 8.8 4.6 0.4 0 0.4 0.4 74 8 69 305 1 0 1 0 -21.2 0 -21 -21.3 02/11/2005 21:30:00 7.1 0.6 8.4 5.3 6.7 0.6 8 4.9 0.4 0 0.4 0.4 71 6 84 305 1 0 1 0 -21.2 0 -21 -21.3 02/11/2005 21:40:00 7.3 0.5 8.4 6.1 6.9 0.5 8 5.7 0.4 0 0.4 0.4 71 4 77 305 1 0 1 0 -21.2 0 -21 -21.3 02/11/2005 21:50:00 7.5 0.5 9.1 5.7 7.1 0.6 8.4 5.3 0.4 0 0.4 0.4 74 4 73 305 1 0 1 0 -21.1 0.1 -20.8 -21.3 02/11/2005 22:00:00 8 0.5 9.1 6.5 7.6 0.6 8.8 5.3 0.4 0 0.4 0.4 68 4 70 305 1 0 1 0 -21 0 -20.8 -21.3 02/11/2005 22:10:00 8.1 0.4 9.5 6.8 7.9 0.5 9.5 6.5 0.4 0 0.4 0.4 68 4 71 305 1 0 1 0 -20.9 0.1 -20.6 -21.1 02/11/2005 22:20:00 8.3 0.5 9.1 6.8 8.1 0.6 9.1 6.5 0.4 0 0.4 0.4 66 4 65 305 1 0 2 0 -20.9 0 -20.8 -21.1 02/11/2005 22:30:00 8.2 0.6 9.5 6.8 8 0.6 9.5 6.1 0.4 0 0.4 0.4 63 5 60 305 1 0 1 0 -20.9 0 -20.8 -21 02/11/2005 22:40:00 8.3 0.6 9.5 6.8 8 0.6 9.1 6.5 0.4 0 0.4 0.4 68 4 70 305 1 0 1 0 -20.8 0 -20.8 -21 02/11/2005 22:50:00 8.5 0.8 10.3 6.1 8.1 0.9 10.3 5.3 0.4 0 0.4 0.4 67 6 70 305 2 0 1 0 -20.7 0 -20.8 -20.8 02/11/2005 23:00:00 10 1 12.6 7.2 9.7 1.1 12.6 6.5 0.4 0 0.4 0.4 63 6 57 305 2 0 1 0 -20.7 0 -20.6 -20.8 02/11/2005 23:10:00 11.9 1 13.7 8.4 11.6 1 13.7 8.4 0.4 0 0.4 0.4 67 5 70 305 2 0 2 0 -20.7 0 -20.8 -21 02/11/2005 23:20:00 12.6 0.7 14.9 10.7 11.9 0.8 14.1 9.9 0.4 0 0.4 0.4 72 5 73 305 2 0 2 0 -20.7 0 -20.6 -20.8 02/11/2005 23:30:00 11 0.9 13 8.4 10.6 0.9 12.6 8 0.4 0 0.4 0.4 70 6 67 305 2 0 2 0 -20.6 0 -20.4 -20.8 02/11/2005 23:40:00 9.8 0.9 12.2 6.8 9.5 1 11.8 6.8 0.4 0 0.4 0.4 62 5 53 305 2 0 2 0 -20.4 0 -20.1 -20.6 02/11/2005 23:50:00 9.8 0.7 11.5 7.6 9.6 0.7 11.5 7.6 0.4 0 0.4 0.4 62 4 63 305 2 0 2 0 -20.2 0 -20.1 -20.2 02/12/2005 00:00:00 9.6 0.6 11.5 8.4 9.4 0.7 10.7 7.6 0.4 0 0.4 0.4 64 5 63 305 2 0 2 0 -20.1 0.1 -19.5 -20.2 02/12/2005 00:10:00 8.9 0.8 10.7 6.5 8.7 0.9 10.7 6.8 0.4 0 0.4 0.4 60 5 57 305 2 0 2 0 -19.8 0.1 -19.5 -20.1 02/12/2005 00:20:00 9.6 0.6 11.1 7.2 9.4 0.8 11.1 7.2 0.4 0 0.4 0.4 57 5 57 305 2 0 2 0 -19.5 0.1 -19.2 -19.7 02/12/2005 00:30:00 9.7 0.7 11.5 8 9.5 0.9 11.5 7.6 0.4 0 0.4 0.4 58 5 57 305 3 0 2 0 -19.4 0 -19.2 -19.5 02/12/2005 00:40:00 10.1 0.8 11.8 7.6 10 0.9 11.8 7.2 0.4 0 0.4 0.4 61 4 65 305 3 0 2 0 -19.3 0 -19 -19.5 02/12/2005 00:50:00 10.6 0.7 11.8 8.4 10.4 0.7 12.2 8.4 0.4 0 0.4 0.4 64 4 62 305 3 0 3 0 -19.2 0 -19 -19.5 02/12/2005 01:00:00 10.7 0.8 12.2 8 10.5 0.9 12.2 7.2 0.4 0 0.4 0.4 64 4 64 305 3 0 3 0 -19.1 0 -18.6 -19.2 02/12/2005 01:10:00 9.8 1 12.6 7.6 9.5 1.2 12.2 6.5 0.4 0 0.4 0.4 60 5 62 305 3 0 3 0 -19 0.1 -18.4 -19.2 02/12/2005 01:20:00 10.3 0.8 11.8 7.6 10.2 0.9 11.8 7.2 0.4 0 0.4 0.4 59 5 63 305 3 0 3 0 -18.9 0.1 -18.4 -19 02/12/2005 01:30:00 10.4 0.8 12.6 8.4 10.1 0.9 12.2 8 0.4 0 0.4 0.4 61 5 64 305 3 0 3 0 -18.9 0.1 -18.6 -19 02/12/2005 01:40:00 11 0.7 12.6 8.8 10.7 0.8 12.6 8.4 0.4 0 0.4 0.4 63 3 59 305 3 0 3 0 -18.7 0 -18.4 -19 02/12/2005 01:50:00 10.8 0.7 12.6 8.4 10.5 0.8 12.6 8 0.4 0 0.4 0.4 64 4 61 305 3 0 4 0 -18.6 0 -18.1 -18.8 02/12/2005 02:00:00 12.6 1 14.9 9.5 12.2 1.2 14.1 8.8 0.4 0 0.4 0.4 66 4 63 305 4 0 4 0 -18.5 0 -18.1 -18.4 02/12/2005 02:10:00 12.9 0.7 14.5 10.7 12.6 0.9 14.1 9.9 0.4 0 0.4 0.4 66 4 68 305 4 0 4 0 -18.4 0.1 -18.1 -18.4 02/12/2005 02:20:00 11.1 1.3 13.7 7.6 11 1.3 13.7 7.6 0.4 0 0.4 0.4 61 6 65 305 4 0 4 0 -18.4 0.1 -18.1 -18.4 02/12/2005 02:30:00 10.9 0.9 13 8.8 10.9 1 13 8.4 0.4 0 0.4 0.4 54 5 57 305 4 0 4 0 -18.3 0.1 -17.9 -18.4 02/12/2005 02:40:00 10.9 1.2 13.3 7.2 10.8 1.4 13.3 7.2 0.4 0 0.4 0.4 52 5 49 305 4 0 4 0 -18.3 0.1 -17.9 -18.4 02/12/2005 02:50:00 10.9 1 13 7.6 10.9 1.1 13.3 7.2 0.4 0 0.4 0.4 56 5 50 305 4 0 4 0 -18.3 0.1 -18.1 -18.4 02/12/2005 03:00:00 10.7 1 13.3 7.2 10.5 1.2 13.3 7.2 0.4 0 0.4 0.4 55 6 69 305 4 0 4 0 -18.3 0 -18.1 -18.4 02/12/2005 03:10:00 11.7 1.5 14.5 8 11.5 1.7 15.6 6.8 0.4 0 0.4 0.4 58 6 60 305 4 0 4 0 -18.3 0 -18.1 -18.4 02/12/2005 03:20:00 12.2 1.2 15.3 8.4 11.9 1.3 15.3 8.4 0.4 0 0.4 0.4 62 6 60 305 4 0 4 0 -18.2 0 -18.1 -18.4 02/12/2005 03:30:00 13.9 1.2 17.6 10.7 13.9 1.2 16.8 10.7 0.4 0 0.4 0.4 61 5 62 305 4 0 4 0 -18.2 0 -18.1 -18.4 02/12/2005 03:40:00 15.4 1.2 18.7 12.6 15.3 1.3 19.1 11.8 0.4 0 0.4 0.4 60 5 60 305 4 0 4 0 -18.2 0 -18.1 -18.4 02/12/2005 03:50:00 15.8 1.1 18.7 12.6 15.7 1.2 18.3 12.2 0.4 0 0.4 0.4 61 5 62 305 4 0 4 0 -18.2 0 -18.1 -18.4 02/12/2005 04:00:00 17.2 1.2 20.2 14.1 16.9 1.3 20.2 13.3 0.4 0 0.4 0.4 63 4 62 305 4 0 4 0 -18.1 0 -17.7 -18.2 02/12/2005 04:10:00 18.2 1 19.9 15.3 18 1.2 20.2 14.1 0.4 0 0.4 0.4 63 3 65 305 4 0 4 0 -18 0 -17.7 -18.2 02/12/2005 04:20:00 18.3 1.1 21 14.9 18.1 1.2 20.6 13.7 0.4 0 0.4 0.4 64 4 64 305 4 0 4 0 -18 0 -17.5 -18.1 02/12/2005 04:30:00 19 1 21 16.1 18.7 1.3 21 15.3 0.4 0 0.4 0.4 64 3 65 305 4 0 5 0 -18 0 -17.9 -18.1 02/12/2005 04:40:00 18.5 0.9 21 16.1 18.3 1 20.6 16.1 0.4 0 0.4 0.4 63 4 65 305 4 0 4 0 -18 0 -17.5 -18.1 02/12/2005 04:50:00 18.3 1.2 21.4 15.3 18.3 1.3 21 14.9 0.4 0 0.4 0.4 61 4 62 305 4 0 4 0 -17.9 0 -17.7 -18.1 02/12/2005 05:00:00 18.3 1.1 20.6 15.3 18.3 1.2 20.6 15.3 0.4 0 0.4 0.4 60 4 59 305 4 0 4 0 -17.9 0 -17.5 -18.1 02/12/2005 05:10:00 19.3 0.9 21.4 16.4 19.2 1 21.8 16.1 0.4 0 0.4 0.4 63 3 60 305 4 0 5 0 -17.9 0.1 -17.3 -18.1 02/12/2005 05:20:00 19.5 0.9 21.4 16.4 19.3 1.1 21.4 16.4 0.4 0 0.4 0.4 64 3 64 305 5 0 5 0 -17.7 0 -17.3 -17.9 02/12/2005 05:30:00 19.3 1 21.8 16.1 19.2 1.1 21.8 15.3 0.4 0 0.4 0.4 65 3 66 305 5 0 5 0 -17.6 0.1 -17.1 -17.9 02/12/2005 05:40:00 18.2 0.9 21.4 15.6 18 1 21.4 14.9 0.4 0 0.4 0.4 64 4 59 305 5 0 5 0 -17.5 0.1 -16.9 -17.7 02/12/2005 05:50:00 18.6 1.1 21.8 16.1 18.5 1.2 21.8 15.3 0.4 0 0.4 0.4 64 4 66 305 5 0 5 0 -17.3 0.1 -16.9 -17.5 02/12/2005 06:00:00 19.2 0.8 21 16.8 19.1 1 21 16.1 0.4 0 0.4 0.4 63 3 61 305 5 0 5 0 -17.3 0.1 -16.9 -17.5 02/12/2005 06:10:00 18.9 1 21.4 15.6 18.9 1.2 21.4 15.3 0.4 0 0.4 0.4 62 4 62 305 5 0 5 0 -17.1 0 -16.6 -17.3 02/12/2005 06:20:00 18.3 1.1 21 15.3 18.2 1.2 21 14.5 0.4 0 0.4 0.4 63 3 66 305 5 0 5 0 -16.9 0.1 -16.6 -17.1 02/12/2005 06:30:00 18.7 1.2 21 15.3 18.7 1.3 21.4 14.9 0.4 0 0.4 0.4 63 3 64 305 5 0 5 0 -16.9 0 -16.4 -16.9 02/12/2005 06:40:00 17.5 1.1 19.9 14.9 17.6 1.1 20.2 15.3 0.4 0 0.4 0.4 61 4 61 305 5 0 5 0 -16.7 0.1 -16.2 -16.9 02/12/2005 06:50:00 17.5 1.3 20.6 14.1 17.5 1.5 20.6 14.1 0.4 0 0.4 0.4 60 5 58 305 5 0 5 0 -16.6 0.1 -16.2 -16.9 02/12/2005 07:00:00 17 1.1 20.2 13.7 17 1.3 20.2 13.7 0.4 0 0.4 0.4 55 4 50 305 6 0 6 0 -16.5 0.1 -16 -16.6 02/12/2005 07:10:00 15.7 1.3 18.7 12.2 15.7 1.4 19.1 12.2 0.4 0 0.4 0.4 53 5 50 305 6 0 6 0 -16.3 0.1 -15.8 -16.6 02/12/2005 07:20:00 16.1 1 18.7 13.3 16.2 1.1 19.1 12.2 0.4 0 0.4 0.4 53 5 48 305 6 0 6 0 -16.2 0.1 -15.8 -16.4 02/12/2005 07:30:00 15.5 1.3 18.7 12.2 15.7 1.3 18.7 11.8 0.4 0 0.4 0.4 55 5 55 305 6 0 6 0 -16.2 0.1 -15.8 -16.4 02/12/2005 07:40:00 15.3 1 17.9 12.2 15.3 1.1 17.9 12.6 0.4 0 0.4 0.4 56 4 62 305 6 0 6 0 -16.1 0 -15.8 -16.2 02/12/2005 07:50:00 14.8 1 17.9 12.6 14.9 1.1 18.7 12.2 0.4 0 0.4 0.4 54 5 46 305 6 0 6 0 -16 0.1 -15.8 -16.4 02/12/2005 08:00:00 15.5 0.9 17.6 13.3 15.6 1 17.9 12.6 0.4 0 0.4 0.4 52 3 52 305 6 0 6 0 -16.3 0.1 -15.8 -16.6 02/12/2005 08:10:00 14.8 0.9 16.8 12.6 15 1 17.6 11.8 0.4 0 0.4 0.4 52 4 51 305 6 0 6 0 -16.3 0 -15.8 -16.6 02/12/2005 08:20:00 14.6 0.8 17.9 12.6 14.6 0.8 17.9 12.6 0.4 0 0.4 0.4 51 4 48 305 6 0 6 0 -16.3 0 -16 -16.6 02/12/2005 08:30:00 13 0.9 15.6 10.7 13.1 1 15.6 10.3 0.4 0 0.4 0.4 50 4 52 305 6 0 6 0 -16.1 0 -15.6 -16.4 02/12/2005 08:40:00 13.4 1 15.6 11.1 13.4 1 15.6 11.1 0.4 0 0.4 0.4 50 4 53 305 6 0 6 0 -15.8 0 -15.2 -16 02/12/2005 08:50:00 12.7 0.9 14.9 10.3 12.7 1 14.5 9.5 0.4 0 0.4 0.4 47 4 45 305 6 0 6 0 -15.5 0 -15 -15.8 02/12/2005 09:00:00 12.4 0.8 14.9 9.5 12.4 0.9 14.9 9.9 0.4 0 0.4 0.4 47 6 56 305 7 0 6 0 -15.1 0.1 -14.6 -15.4 02/12/2005 09:10:00 11.5 1 13.7 8.8 11.5 1 13.7 8.8 0.4 0 0.4 0.4 45 5 43 305 7 0 7 0 -15.1 0.1 -14.6 -15.2 02/12/2005 09:20:00 11.8 0.9 14.1 9.1 11.8 1 14.1 9.1 0.4 0 0.4 0.4 51 5 48 305 7 0 7 0 -14.4 0 -14.3 -14.6 02/12/2005 09:30:00 12 0.8 14.5 9.1 12 0.9 14.1 9.1 0.4 0 0.4 0.4 48 5 51 305 7 0 7 0 -14.2 0 -13.7 -14.4 02/12/2005 09:40:00 10 0.9 12.6 8 10 1 13 7.6 0.4 0 0.4 0.4 47 5 41 305 8 0 7 0 -14 0 -13.7 -14.3 02/12/2005 09:50:00 10.3 1 13.3 8 10.2 1.1 13.7 8 0.4 0 0.4 0.4 49 5 48 305 8 0 8 0 -13.7 0.2 -12.9 -14.1 02/12/2005 10:00:00 10.6 1.2 13.3 7.6 10.6 1.3 13.3 7.2 0.4 0 0.4 0.4 55 5 56 305 8 0 8 0 -12.9 0.1 -12.3 -13.3 02/12/2005 10:10:00 10.8 1.1 13.7 8.4 10.6 1.1 13 8 0.4 0 0.4 0.4 56 6 48 305 9 0 9 0 -12.6 0 -12.1 -12.9 02/12/2005 10:20:00 9.9 0.9 12.6 7.2 9.6 1 12.2 7.6 0.4 0 0.4 0.4 58 6 59 305 9 0 9 0 -12.2 0.2 -11.7 -12.5 02/12/2005 10:30:00 10.6 1.1 13.7 8 10.3 1.2 13.3 7.2 0.4 0 0.4 0.4 62 6 67 305 10 0 9 0 -11.4 0.2 -10.9 -12.1 02/12/2005 10:40:00 11.2 1.5 14.9 8 10.7 1.5 14.1 7.6 0.4 0 0.4 0.4 64 8 64 305 11 0 11 0 -10.7 0.2 -10.2 -11.3 02/12/2005 10:50:00 13.8 1.3 17.2 8.4 13.4 1.5 17.2 9.1 0.4 0 0.4 0.4 67 6 62 305 12 0 12 0 -10.1 0 -9.6 -10.4 02/12/2005 11:00:00 14.4 1.3 17.9 11.5 13.9 1.4 17.9 10.3 0.4 0 0.4 0.4 72 5 70 305 12 0 12 0 -9.9 0.1 -9.2 -10 02/12/2005 11:10:00 12.8 1.1 16.4 10.3 12.3 1.2 16.4 9.1 0.4 0 0.4 0.4 74 6 71 305 13 0 14 0 -9.8 0 -9.2 -9.8 02/12/2005 11:20:00 14.6 1.3 18.7 11.1 13.9 1.3 17.2 10.3 0.4 0 0.4 0.4 75 6 80 305 15 0 14 0 -9.5 0 -9 -9.8 02/12/2005 11:30:00 14.6 1.1 17.2 11.8 14 1.2 17.6 10.3 0.4 0 0.4 0.4 77 5 78 305 17 0 17 0 -9.3 0 -9 -9.4 02/12/2005 11:40:00 12.4 1.7 17.6 9.1 11.9 1.7 16.8 8.8 0.4 0 0.4 0.4 73 7 82 305 18 0 18 0 -9.3 0 -8.8 -9.6 02/12/2005 11:50:00 12 0.8 14.1 8.4 11.7 0.8 14.1 8.8 0.4 0 0.4 0.4 67 4 73 305 20 0 19 0 -9.5 0 -9.2 -9.6 02/12/2005 12:00:00 12.6 1.1 16.1 10.3 12.2 1.1 15.6 9.9 0.4 0 0.4 0.4 70 6 69 305 22 1 23 0 -9.4 0 -9.2 -9.6 02/12/2005 12:10:00 13.3 1.3 18.3 8.8 12.8 1.5 16.1 9.1 0.4 0 0.4 0.4 75 7 78 305 24 1 24 0 -9.2 0 -9 -9.4 02/12/2005 12:20:00 14 2 19.9 8.8 13.4 2.3 21 8 0.4 0 0.4 0.4 78 11 59 305 26 1 27 0 -9.1 0 -8.8 -9.2 02/12/2005 12:30:00 14.7 2.4 22.9 9.5 14.1 2.4 22.1 8 0.4 0 0.4 0.4 78 10 66 305 29 1 29 0 -8.8 0 -8.8 -9 02/12/2005 12:40:00 14.5 2.3 21.8 9.1 14.2 2.4 21.8 8.4 0.4 0 0.4 0.4 80 13 87 305 32 1 33 0 -8.8 0 -8.6 -9 02/12/2005 12:50:00 15.5 2.1 21 9.9 14.9 2.3 21.8 9.1 0.4 0 0.4 0.4 80 11 71 305 35 1 33 0 -8.7 0 -8.6 -8.8 02/12/2005 13:00:00 15.6 2.1 21 10.3 15 2.2 20.6 8.4 0.4 0 0.4 0.4 81 10 93 305 38 1 39 0 -8.6 0 -8.4 -8.8 02/12/2005 13:10:00 14.5 2.3 21.8 8 14.1 2.4 21.8 9.1 0.4 0 0.4 0.4 78 11 96 305 41 1 40 0 -8.6 0 -8.4 -8.8 02/12/2005 13:20:00 13.9 2.4 20.6 8 13.4 2.4 20.2 7.6 0.4 0 0.4 0.4 79 13 76 305 43 1 45 0 -8.6 0 -8.4 -8.8 02/12/2005 13:30:00 12.5 2.1 19.9 6.5 12.2 2.2 21.4 5.3 0.4 0 0.4 0.4 78 15 79 305 46 1 46 0 -8.6 0 -8.4 -8.8 02/12/2005 13:40:00 10.5 2.9 17.9 4.6 10 2.9 16.8 4.6 0.4 0 0.4 0.4 91 19 84 305 49 1 48 0 -8.3 0.1 -8.2 -8.6 02/12/2005 13:50:00 9.6 2.4 15.6 4.6 9.3 2.5 16.4 4.6 0.4 0 0.4 0.4 94 19 92 305 51 1 51 0 -8.2 0 -7.9 -8.2 02/12/2005 14:00:00 10.2 2.6 18.7 3.4 9.6 2.5 19.1 3.8 0.4 0 0.4 0.4 101 20 121 305 54 1 54 0 -8.2 0 -7.9 -8.4 02/12/2005 14:10:00 10.6 2 16.8 6.1 10 1.9 15.6 5.7 0.4 0 0.4 0.4 107 15 108 305 57 1 57 0 -7.9 0 -7.7 -8.2 02/12/2005 14:20:00 12.1 2.5 18.3 5.3 11.7 2.4 18.3 5.7 0.4 0 0.4 0.4 111 16 120 305 59 1 59 0 -7.8 0 -7.7 -7.9 02/12/2005 14:30:00 13.3 2 17.9 8.4 12.6 2 18.7 7.2 0.4 0 0.4 0.4 108 13 109 305 62 0 62 0 -7.8 0 -7.7 -7.9 02/12/2005 14:40:00 12.8 2 21.8 8.4 12.2 1.9 18.7 8 0.4 0 0.4 0.4 108 14 116 305 64 1 63 0 -7.7 0 -7.5 -7.9 02/12/2005 14:50:00 13.4 2.2 18.3 8.4 12.9 2 17.2 8 0.4 0 0.4 0.4 109 11 114 305 66 0 66 0 -7.6 0 -7.3 -7.7 02/12/2005 15:00:00 12.7 1.7 18.3 6.8 12.1 1.7 16.8 6.8 0.4 0 0.4 0.4 109 10 97 305 68 1 69 0 -7.5 0.1 -7.3 -7.7 02/12/2005 15:10:00 13.1 1.4 17.2 9.5 12.4 1.3 16.4 8.8 0.4 0 0.4 0.4 105 8 105 305 71 1 71 0 -7.4 0 -7.1 -7.5 02/12/2005 15:20:00 12.8 1.4 17.2 9.1 12 1.5 16.8 6.8 0.4 0 0.4 0.4 108 9 118 305 73 1 73 0 -7.1 0 -6.9 -7.3 02/12/2005 15:30:00 12.4 1.3 16.1 9.1 11.8 1.3 16.4 8.4 0.4 0 0.4 0.4 110 9 118 305 76 1 75 0 -6.9 0 -6.7 -7.1 02/12/2005 15:40:00 12.4 1.5 16.4 8 11.8 1.5 15.3 7.6 0.4 0 0.4 0.4 115 10 122 305 78 1 79 0 -6.5 0.1 -6.2 -6.9 02/12/2005 15:50:00 10.6 1.5 13.7 6.8 10.2 1.5 13.7 6.8 0.4 0 0.4 0.4 122 11 116 305 81 1 81 0 -5.9 0.2 -5.3 -6.4 02/12/2005 16:00:00 11.4 1.5 15.3 7.6 11.2 1.5 16.1 7.2 0.4 0 0.4 0.4 125 10 129 305 84 1 85 0 -5 0.1 -4.7 -5.6 02/12/2005 16:10:00 10.8 1.3 14.5 8 10.6 1.3 14.1 6.8 0.4 0 0.4 0.4 126 11 136 305 87 1 87 0 -4.7 0.1 -4.5 -4.9 02/12/2005 16:20:00 11.8 1 14.5 8.8 11.5 1.1 14.9 8.8 0.4 0 0.4 0.4 129 7 151 305 89 0 88 0 -4.3 0 -4 -4.5 02/12/2005 16:30:00 11.4 0.7 13.3 8.4 11.1 0.9 13 8 0.4 0 0.4 0.4 131 5 129 305 92 1 91 0 -4.1 0 -3.8 -4.2 02/12/2005 16:40:00 11.1 0.5 12.6 9.5 10.9 0.5 12.6 9.1 0.4 0 0.4 0.4 133 3 128 305 94 0 93 0 -4.2 0.1 -4 -4.5 02/12/2005 16:50:00 10.9 0.5 12.6 9.5 10.6 0.5 11.8 9.1 0.4 0 0.4 0.4 135 3 125 305 95 0 95 0 -4.4 0 -4.2 -4.7 02/12/2005 17:00:00 11.1 0.7 12.6 9.1 10.7 0.6 12.2 9.1 0.4 0 0.4 0.4 136 3 133 305 96 0 96 0 -4.4 0 -4 -4.5 02/12/2005 17:10:00 12.1 0.4 13 11.1 11.7 0.5 12.6 10.3 0.4 0 0.4 0.4 137 3 134 305 97 0 96 0 -4.4 0 -4 -4.5 02/12/2005 17:20:00 12 0.4 13.3 10.7 11.7 0.5 13 10.3 0.4 0 0.4 0.4 139 3 140 305 98 0 97 0 -4.5 0 -4.2 -4.7 02/12/2005 17:30:00 12.2 0.5 14.1 10.3 11.8 0.6 13.7 10.3 0.4 0 0.4 0.4 141 3 141 305 98 0 98 0 -4.9 0 -4.7 -5.1 02/12/2005 17:40:00 12.3 0.6 13.7 9.9 12 0.6 13.3 10.3 0.4 0 0.4 0.4 142 3 148 305 98 0 98 0 -5.1 0.2 -4.7 -5.6 02/12/2005 17:50:00 12.1 0.6 13.7 9.9 11.6 0.6 13.3 9.9 0.4 0 0.4 0.4 142 3 146 305 97 0 97 0 -5.5 0 -5.3 -5.6 02/12/2005 18:00:00 12.1 0.8 14.5 10.3 11.7 0.8 14.1 9.5 0.4 0 0.7 0.4 143 4 145 305 97 0 97 0 -5.3 0.1 -4.9 -5.6 02/12/2005 18:10:00 11.9 1 14.9 9.5 11.6 1 14.5 9.1 0.4 0 0.4 0.4 145 5 136 305 98 0 98 0 -4.9 0.1 -4.7 -5.1 02/12/2005 18:20:00 12.2 0.7 14.9 10.7 11.7 0.7 14.1 9.9 0.4 0 0.4 0.4 143 4 147 305 98 0 98 0 -5.2 0 -5.1 -5.3 02/12/2005 18:30:00 12.9 0.8 15.3 10.7 12.5 0.8 15.3 10.3 0.4 0 0.4 0.4 138 5 137 305 98 0 97 0 -5.2 0 -5.1 -5.6 02/12/2005 18:40:00 12.7 0.8 14.5 10.3 12.4 0.9 14.5 8.8 0.4 0 0.4 0.4 132 5 133 305 98 0 99 0 -5 0 -4.7 -5.3 02/12/2005 18:50:00 12.7 0.9 14.9 10.7 12.4 0.9 14.9 9.5 0.4 0 0.4 0.4 133 5 136 305 99 0 100 0 -4.9 0 -4.7 -5.1 02/12/2005 19:00:00 12.4 0.8 14.5 10.3 11.9 0.8 14.5 9.9 0.4 0 0.4 0.4 137 4 136 305 99 0 99 0 -5.1 0 -4.9 -5.3 02/12/2005 19:10:00 12.9 0.6 14.5 11.1 12.3 0.6 13.7 10.7 0.4 0 0.4 0.4 136 3 138 305 99 0 99 0 -5.1 0 -4.9 -5.1 02/12/2005 19:20:00 12.9 0.8 14.9 9.9 12.4 0.7 14.1 10.3 0.4 0 0.4 0.4 134 4 139 305 100 0 100 0 -5 0 -4.7 -5.1 02/12/2005 19:30:00 13.1 0.7 15.3 10.7 12.6 0.7 14.9 10.7 0.4 0 0.4 0.4 137 4 136 305 100 0 100 0 -4.9 0 -4.7 -5.1 02/12/2005 19:40:00 13.1 0.8 15.6 10.7 12.6 0.8 14.5 10.3 0.4 0 0.4 0.4 136 4 141 305 101 0 101 0 -4.9 0 -4.7 -5.1 02/12/2005 19:50:00 12.6 0.7 14.5 10.7 12.1 0.7 13.7 10.3 0.4 0 0.4 0.4 135 4 135 305 101 0 101 0 -5.2 0 -4.9 -5.3 02/12/2005 20:00:00 12.9 0.7 14.5 10.3 12.6 0.7 14.1 10.3 0.4 0 0.4 0.4 132 4 134 305 101 0 101 0 -5.2 0 -5.1 -5.6 02/12/2005 20:10:00 12.7 0.7 14.1 10.7 12.4 0.7 14.5 10.7 0.4 0 0.4 0.4 131 4 139 305 101 0 101 0 -5.1 0 -4.9 -5.1 02/12/2005 20:20:00 12.9 0.6 14.5 10.7 12.5 0.7 14.5 10.3 0.4 0 0.4 0.4 131 4 133 305 102 0 102 0 -5.1 0 -4.9 -5.3 02/12/2005 20:30:00 12.8 0.8 14.9 10.7 12.4 0.8 14.5 10.3 0.4 0 0.4 0.4 132 5 129 305 102 0 102 0 -5.1 0 -4.9 -5.3 02/12/2005 20:40:00 12.8 0.8 15.3 11.1 12.4 0.7 14.1 10.3 0.4 0 0.4 0.4 136 5 144 305 102 0 102 0 -5.1 0 -4.9 -5.3 02/12/2005 20:50:00 13.1 0.9 16.1 9.5 12.7 0.8 15.3 9.5 0.4 0 0.4 0.4 136 5 143 305 102 0 103 0 -5.1 0 -4.9 -5.1 02/12/2005 21:00:00 12.6 0.8 14.9 11.1 12.2 0.8 14.5 9.9 0.4 0 0.4 0.4 136 4 135 305 103 0 103 0 -5.2 0 -4.9 -5.3 02/12/2005 21:10:00 12.3 0.9 14.9 10.3 11.9 0.8 14.1 10.3 0.4 0 0.4 0.4 136 5 140 305 103 0 103 0 -5.3 0 -5.1 -5.6 02/12/2005 21:20:00 11.9 1 14.9 9.5 11.4 1 14.9 9.1 0.4 0 0.4 0.4 138 5 137 305 103 0 103 0 -5.4 0 -5.1 -5.6 02/12/2005 21:30:00 12.5 0.8 15.3 10.7 12 0.8 14.5 9.9 0.4 0 0.4 0.4 137 5 139 305 103 0 103 0 -5.5 0 -5.1 -5.8 02/12/2005 21:40:00 12.1 0.8 14.5 9.5 11.5 0.7 13.3 9.5 0.4 0 0.4 0.4 138 4 140 305 103 0 103 0 -5.7 0 -5.6 -5.8 02/12/2005 21:50:00 12.5 1.2 16.8 8.8 12.1 1.2 15.6 8.8 0.4 0 0.4 0.4 140 6 148 305 103 0 103 0 -5.2 0.1 -4.9 -5.6 02/12/2005 22:00:00 12.6 0.9 14.5 9.9 12.1 0.9 14.9 9.9 0.4 0 0.4 0.4 139 5 131 305 104 0 103 0 -5.1 0 -4.9 -5.1 02/12/2005 22:10:00 11.9 1 14.5 8.4 11.5 1.1 15.6 8.8 0.4 0 0.4 0.4 139 6 156 305 104 0 104 0 -4.9 0 -4.7 -5.1 02/12/2005 22:20:00 12.5 1 14.9 9.5 12 1 14.9 9.5 0.4 0 0.4 0.4 138 6 136 305 104 0 104 0 -4.7 0 -4.5 -4.9 02/12/2005 22:30:00 11.3 1.1 14.9 8.8 10.8 1 13.7 8.4 0.4 0 0.4 0.4 141 7 141 305 105 0 105 0 -4.7 0 -4.2 -4.7 02/12/2005 22:40:00 12 1 14.5 9.5 11.6 0.9 14.5 9.1 0.4 0 0.4 0.4 139 5 148 305 105 0 105 0 -4.7 0 -4 -4.9 02/12/2005 22:50:00 12 0.9 14.1 8.8 11.6 0.9 13.7 8.8 0.4 0 0.4 0.4 130 4 131 305 106 0 106 0 -4.5 0 -4 -4.7 02/12/2005 23:00:00 11.6 1 14.9 8.8 11.1 1 14.1 8.4 0.4 0 0.4 0.4 131 5 129 305 107 0 107 0 -4.6 0.1 -4.5 -4.7 02/12/2005 23:10:00 11.9 1 14.1 8.8 11.4 1.1 14.1 8.8 0.4 0 0.4 0.4 130 6 127 305 107 0 107 0 -4.6 0 -4.5 -4.7 02/12/2005 23:20:00 11.4 1.4 15.3 5.7 11 1.4 14.9 6.5 0.4 0 0.4 0.4 130 9 136 305 108 0 108 0 -4.4 0 -4.2 -4.5 02/12/2005 23:30:00 11.3 1.1 14.1 8.8 10.9 1.1 13.3 7.6 0.4 0 0.4 0.4 131 6 129 305 108 0 108 0 -4.4 0 -4.2 -4.7 02/12/2005 23:40:00 11.9 0.9 14.1 9.5 11.5 0.9 13.7 9.5 0.4 0 0.4 0.4 134 5 133 305 109 0 109 0 -4.4 0 -4.5 -4.7 02/12/2005 23:50:00 12.7 1 15.3 9.5 12.3 1 14.5 9.5 0.4 0 0.4 0.4 134 5 133 305 109 0 109 0 -4.5 0 -4.5 -4.7 02/13/2005 00:00:00 12.6 0.9 15.3 10.7 12.2 0.9 14.5 10.3 0.4 0 0.4 0.4 132 4 137 305 109 0 109 0 -4.5 0 -4 -4.7 02/13/2005 00:10:00 12.3 0.9 14.5 9.5 11.9 0.8 13.7 9.1 0.4 0 0.4 0.4 134 5 135 305 109 0 109 0 -4.5 0 -4.5 -4.7 02/13/2005 00:20:00 12.3 0.9 14.9 9.5 11.9 1 14.5 9.5 0.4 0 0.4 0.4 136 5 146 305 109 0 109 0 -4.5 0 -4.5 -4.7 02/13/2005 00:30:00 11.9 0.8 13.7 9.9 11.5 0.8 13.3 9.9 0.4 0 0.4 0.4 135 5 139 305 109 0 109 0 -4.6 0 -4.5 -4.7 02/13/2005 00:40:00 12.8 1 14.9 9.9 12.3 0.9 14.9 9.9 0.4 0 0.4 0.4 132 5 135 305 109 0 109 0 -4.5 0 -4.5 -4.7 02/13/2005 00:50:00 13.3 0.9 15.3 11.1 13 1 14.9 10.7 0.4 0 0.4 0.4 135 5 134 305 109 0 109 0 -4.5 0 -4.5 -4.7 02/13/2005 01:00:00 12.6 0.9 14.9 10.7 12.3 0.8 14.5 10.3 0.4 0 0.4 0.4 135 5 132 305 109 0 109 0 -4.6 0 -4.5 -4.7 02/13/2005 01:10:00 12.6 1 14.9 8.8 12.3 1 14.5 8.8 0.4 0 0.4 0.4 135 4 136 305 109 0 109 0 -4.7 0 -4.5 -4.7 02/13/2005 01:20:00 12.3 1 14.5 9.9 12 0.8 14.1 9.5 0.4 0 0.4 0.4 134 4 136 305 109 0 109 0 -4.7 0 -4.5 -4.7 02/13/2005 01:30:00 12.7 1 14.9 9.9 12.3 0.9 14.1 9.5 0.4 0 0.4 0.4 129 5 126 305 109 0 109 0 -4.7 0 -4.5 -4.7 02/13/2005 01:40:00 12.2 1.1 14.9 8.8 11.9 1.1 14.5 8.4 0.4 0 0.4 0.4 128 6 123 305 109 0 109 0 -4.5 0 -4.5 -4.7 02/13/2005 01:50:00 11.8 1.3 15.6 7.6 11.4 1.3 14.9 7.6 0.4 0 0.4 0.4 126 9 128 305 110 0 110 0 -4.4 0 -4.2 -4.5 02/13/2005 02:00:00 11.3 1.5 14.5 7.6 11.1 1.5 14.9 7.6 0.4 0 0.4 0.4 128 9 141 305 110 0 110 0 -4.4 0 -3.8 -4.5 02/13/2005 02:10:00 11.1 1.3 15.3 8 10.9 1.3 15.6 7.2 0.4 0 0.4 0.4 132 10 139 305 110 0 111 0 -4.5 0 -4 -4.7 02/13/2005 02:20:00 10.1 1.5 15.6 6.8 9.7 1.5 14.5 5.7 0.4 0 0.4 0.4 117 12 118 305 110 0 110 0 -4.7 0 -4.2 -4.7 02/13/2005 02:30:00 10 1.6 14.1 6.5 9.5 1.5 14.1 6.1 0.4 0 0.4 0.4 116 13 130 305 110 0 110 0 -4.7 0 -4.7 -4.7 02/13/2005 02:40:00 8.7 1.3 12.2 5.7 8.2 1.2 11.8 5.3 0.4 0 0.4 0.4 120 14 129 305 110 0 110 0 -4.7 0 -4.2 -4.7 02/13/2005 02:50:00 9.5 1.6 14.1 5.7 9 1.6 14.1 5.7 0.4 0 0.4 0.4 119 13 123 305 110 0 110 0 -4.7 0 -4.7 -4.7 02/13/2005 03:00:00 9.7 1.6 13.3 5.3 9.3 1.6 13 5.3 0.4 0 0.4 0.4 115 14 124 305 110 0 110 0 -4.7 0 -4.5 -4.7 02/13/2005 03:10:00 10.2 2 14.5 4.9 9.6 2 14.9 4.2 0.4 0 0.4 0.4 118 11 125 305 110 0 110 0 -4.7 0 -4.5 -4.7 02/13/2005 03:20:00 12.7 1.7 17.2 8 12.6 1.6 17.2 8.4 0.4 0 0.4 0.4 132 10 140 305 110 0 110 0 -4.7 0 -4.5 -4.7 02/13/2005 03:30:00 14.5 1.3 18.3 8.4 14.1 1.3 17.9 10.3 0.4 0 0.4 0.4 131 7 124 305 110 0 111 0 -4.9 0 -4.7 -5.1 02/13/2005 03:40:00 14.2 1.5 19.1 8.8 13.8 1.5 17.9 9.9 0.4 0 0.4 0.4 131 6 138 305 110 0 110 0 -5.2 0 -4.9 -5.3 02/13/2005 03:50:00 12.2 1.9 16.8 8 12 1.8 17.2 7.2 0.4 0 0.4 0.4 130 11 131 305 109 0 109 0 -5.2 0 -5.1 -5.3 02/13/2005 04:00:00 11.7 1.8 17.2 7.6 11.4 1.8 17.6 6.8 0.4 0 0.4 0.4 127 13 140 305 109 0 109 0 -5.3 0.1 -4.7 -5.6 02/13/2005 04:10:00 11.1 2.1 16.4 5.7 10.7 1.9 15.3 6.5 0.4 0 0.4 0.4 114 13 119 305 108 0 108 0 -5.4 0 -5.1 -5.6 02/13/2005 04:20:00 12.4 1.8 17.6 7.2 11.8 1.8 17.2 6.8 0.4 0 0.4 0.4 117 11 118 305 108 0 108 0 -5.5 0 -5.6 -5.6 02/13/2005 04:30:00 12 1.9 17.2 7.6 11.5 1.8 16.1 7.6 0.4 0 0.4 0.4 120 10 121 305 108 0 108 0 -5.7 0.1 -5.6 -6 02/13/2005 04:40:00 11.8 1.5 16.4 7.6 11.4 1.6 16.1 7.2 0.4 0 0.4 0.4 125 12 127 305 107 0 107 0 -5.8 0 -5.6 -6 02/13/2005 04:50:00 12 1.3 15.6 8.4 11.7 1.3 16.1 7.6 0.4 0 0.4 0.4 130 7 134 305 107 0 107 0 -5.7 0 -5.6 -5.8 02/13/2005 05:00:00 12 1 14.1 9.1 11.5 1 13.7 8.8 0.4 0 0.4 0.4 130 5 126 305 106 0 106 0 -5.7 0 -5.6 -5.8 02/13/2005 05:10:00 10.3 1.6 14.1 6.8 10 1.7 13.3 6.5 0.4 0 0.4 0.4 129 9 134 305 106 0 106 0 -5.7 0 -5.6 -5.8 02/13/2005 05:20:00 10.7 0.8 12.2 7.6 10.3 0.8 11.8 7.6 0.4 0 0.4 0.4 137 5 131 305 106 0 106 0 -5.9 0 -5.8 -6 02/13/2005 05:30:00 10.8 1.5 14.5 7.2 10.4 1.4 14.1 6.8 0.4 0 0.4 0.4 132 9 131 305 105 0 105 0 -6.1 0 -6 -6.2 02/13/2005 05:40:00 10.6 1.7 14.5 6.1 10.3 1.7 14.5 5.3 0.4 0 0.4 0.4 123 12 111 305 105 0 105 0 -6.1 0 -5.8 -6.2 02/13/2005 05:50:00 11.1 1.3 14.5 7.6 11 1.4 14.5 7.2 0.4 0 0.4 0.4 123 12 140 305 104 0 105 0 -6.1 0 -6 -6.2 02/13/2005 06:00:00 10.5 0.8 12.6 8 10.2 0.8 12.6 7.2 0.4 0 0.4 0.4 133 4 147 305 104 0 104 0 -6.4 0.1 -6 -6.7 02/13/2005 06:10:00 8.3 1.5 11.8 4.9 8.1 1.4 11.5 4.9 0.4 0 0.4 0.4 135 6 136 305 103 0 103 0 -6.4 0 -6.2 -6.7 02/13/2005 06:20:00 9.4 1.2 12.6 6.8 9.1 1.1 12.2 6.5 0.4 0 0.4 0.4 128 8 120 305 103 0 103 0 -6.1 0.2 -5.6 -6.4 02/13/2005 06:30:00 10.5 1.2 14.9 6.8 10.3 1.1 13.7 6.8 0.4 0 0.4 0.4 131 7 133 305 104 0 103 0 -5.5 0 -5.3 -5.6 02/13/2005 06:40:00 8.9 1 12.6 5.7 8.7 1 11.8 4.9 0.4 0 0.4 0.4 131 6 133 305 105 0 104 0 -5.6 0 -5.6 -5.8 02/13/2005 06:50:00 8.8 0.8 11.5 7.2 8.4 0.8 10.3 6.5 0.4 0 0.4 0.4 134 5 129 305 105 0 105 0 -5.6 0 -5.6 -5.8 02/13/2005 07:00:00 9.5 0.9 12.6 6.5 9.2 0.8 12.2 7.2 0.4 0 0.4 0.4 134 7 139 305 105 0 106 0 -5.5 0 -4.9 -5.8 02/13/2005 07:10:00 10.9 1.2 13.7 7.6 10.6 1.2 13.3 7.2 0.4 0 0.4 0.4 134 7 129 305 106 0 106 0 -5.5 0 -5.3 -5.6 02/13/2005 07:20:00 8.4 1.4 11.8 4.9 8.2 1.5 11.5 4.9 0.4 0 0.4 0.4 128 12 136 305 106 0 106 0 -5.6 0 -5.1 -5.8 02/13/2005 07:30:00 7.7 1.1 10.7 4.9 7.7 1.1 11.1 5.3 0.4 0 0.4 0.4 136 9 142 305 106 0 106 0 -5.9 0.1 -5.6 -6 02/13/2005 07:40:00 10.1 1.7 14.5 5.7 9.8 1.7 14.1 6.5 0.4 0 0.4 0.4 134 7 137 305 105 0 105 0 -5.9 0 -5.8 -6 02/13/2005 07:50:00 10.9 1.7 15.3 7.2 10.7 1.7 14.9 6.5 0.4 0 0.4 0.4 129 11 124 305 105 0 105 0 -5.9 0 -5.8 -6 02/13/2005 08:00:00 8.8 1.2 12.6 5.7 8.6 1.2 12.2 5.3 0.4 0 0.4 0.4 129 14 144 305 105 0 105 0 -6 0 -5.6 -6 02/13/2005 08:10:00 9.1 1.7 13.3 5.3 8.8 1.7 13.3 3.8 0.4 0 0.4 0.4 119 13 134 305 104 0 104 0 -6 0 -5.8 -6 02/13/2005 08:20:00 7.1 1.4 10.3 4.2 6.7 1.4 9.9 3.8 0.4 0 0.4 0.4 110 18 118 305 104 0 104 0 -6 0 -5.6 -6 02/13/2005 08:30:00 7.6 1.6 11.5 4.2 7 1.5 10.7 3.8 0.4 0 0.4 0.4 105 14 137 305 104 0 104 0 -5.9 0 -5.8 -6 02/13/2005 08:40:00 6.9 1.3 11.5 4.2 6.5 1.4 10.7 2.6 0.4 0 0.4 0.4 96 17 99 305 104 0 104 0 -5.9 0 -5.8 -6 02/13/2005 08:50:00 8.8 1.5 13 5.3 8.3 1.5 12.2 4.9 0.4 0 0.4 0.4 92 13 90 305 104 0 104 0 -6 0 -5.8 -6.2 02/13/2005 09:00:00 8.3 1.5 12.2 4.9 7.7 1.6 12.2 3.8 0.4 0 0.4 0.4 103 14 105 305 104 0 104 0 -6.1 0 -6 -6.2 02/13/2005 09:10:00 7.9 1.7 12.2 4.9 7.7 1.7 11.8 4.2 0.4 0 0.4 0.4 115 17 136 305 104 0 105 0 -6.1 0 -6 -6.2 02/13/2005 09:20:00 8.5 1.7 14.5 4.2 8.1 1.8 14.1 4.6 0.4 0 0.4 0.4 94 17 74 305 104 0 104 0 -6.1 0 -6 -6.2 02/13/2005 09:30:00 10.2 1.9 16.4 5.7 9.8 1.9 15.3 6.5 0.4 0 0.4 0.4 87 13 90 305 104 0 104 0 -6 0 -5.8 -6.2 02/13/2005 09:40:00 11.9 1.5 16.4 7.6 11.4 1.6 15.6 6.8 0.4 0 0.4 0.4 87 11 99 305 104 0 104 0 -6.5 0.2 -6 -7.1 02/13/2005 09:50:00 12.6 1.3 15.3 9.1 12.1 1.3 15.6 8.4 0.4 0 0.4 0.4 84 8 79 305 102 1 102 0 -7.1 0 -6.9 -7.3 02/13/2005 10:00:00 13.4 1.5 16.8 9.1 12.8 1.5 16.8 8 0.4 0 0.4 0.4 84 8 75 305 101 0 100 0 -7.2 0 -7.1 -7.3 02/13/2005 10:10:00 13.2 1.6 19.1 8.4 12.6 1.7 18.3 8 0.4 0 0.4 0.4 87 9 87 305 100 0 100 0 -7.1 0 -6.9 -7.3 02/13/2005 10:20:00 13.3 1.5 17.2 9.5 12.7 1.5 17.2 9.1 0.4 0 0.4 0.4 86 8 82 305 99 0 99 0 -7 0 -6.9 -7.1 02/13/2005 10:30:00 13.3 1.4 17.2 9.9 12.9 1.4 16.8 9.5 0.4 0 0.4 0.4 87 8 84 305 99 0 99 0 -7.1 0 -6.9 -7.1 02/13/2005 10:40:00 13.6 1.5 17.2 8 13.2 1.6 17.6 8.4 0.4 0 0.4 0.4 89 9 82 305 99 0 98 0 -7.1 0 -6.9 -7.3 02/13/2005 10:50:00 13.1 1 16.1 9.9 12.8 1.1 15.6 9.1 0.4 0 0.4 0.4 80 7 81 305 98 0 98 0 -7.1 0 -6.9 -7.5 02/13/2005 11:00:00 13 0.9 16.1 9.5 12.7 1 16.1 9.9 0.4 0 0.4 0.4 78 6 114 305 98 0 98 0 -7.5 0 -7.3 -7.7 02/13/2005 11:10:00 13 1 16.1 10.3 12.7 1 15.3 9.5 0.4 0 0.4 0.4 77 5 77 305 97 0 97 0 -7.5 0 -7.3 -7.7 02/13/2005 11:20:00 12.1 1.1 16.1 9.9 11.7 1.1 16.1 9.1 0.4 0 0.4 0.4 77 5 70 305 97 0 97 0 -7.3 0 -7.1 -7.5 02/13/2005 11:30:00 11.7 0.6 13.3 9.9 11.5 0.7 13.7 9.1 0.4 0 0.4 0.4 74 5 67 305 97 0 97 0 -7.5 0 -7.3 -7.7 02/13/2005 11:40:00 11.1 0.8 13 8 10.8 0.9 12.6 8 0.4 0 0.4 0.4 80 6 95 305 97 0 97 0 -7.6 0 -7.3 -7.7 02/13/2005 11:50:00 11.6 1 13.7 9.1 11.3 1.1 13.7 9.1 0.4 0 0.4 0.4 78 6 78 305 97 0 97 0 -7.7 0 -7.5 -7.7 02/13/2005 12:00:00 11.3 0.8 13.3 9.1 11 0.9 13.7 8.4 0.4 0 0.4 0.4 76 6 88 305 96 0 96 0 -7.8 0 -7.7 -7.9 02/13/2005 12:10:00 10.7 0.8 13 8.4 10.5 0.8 13 8.4 0.4 0 0.4 0.4 74 5 78 305 96 0 96 0 -7.9 0 -7.7 -8.2 02/13/2005 12:20:00 11.1 0.6 12.6 9.5 10.9 0.7 12.6 8.8 0.4 0 0.4 0.4 70 4 71 305 95 0 95 0 -8.2 0 -7.9 -8.4 02/13/2005 12:30:00 11.3 0.5 12.2 9.9 11.2 0.5 12.6 9.5 0.4 0 0.4 0.4 70 3 65 305 95 0 95 0 -8.4 0 -8.2 -8.6 02/13/2005 12:40:00 12.2 0.6 13.3 9.9 12 0.6 13.3 9.9 0.4 0 0.4 0.4 63 4 64 305 94 0 94 0 -8.5 0.1 -8.4 -8.8 02/13/2005 12:50:00 12.3 0.7 14.1 9.9 12.2 0.8 14.1 9.5 0.4 0 0.4 0.4 60 5 67 305 93 0 93 0 -8.8 0.2 -8.4 -9.2 02/13/2005 13:00:00 13.5 0.6 14.9 11.8 13.4 0.7 14.9 10.7 0.4 0 0.4 0.4 60 3 60 305 92 1 91 0 -9.5 0.2 -9 -10 02/13/2005 13:10:00 13.6 0.6 15.3 11.8 13.4 0.6 14.9 11.8 0.4 0 0.4 0.4 57 5 58 305 89 0 90 0 -9.9 0 -9.8 -10.2 02/13/2005 13:20:00 13.7 0.6 14.9 11.8 13.4 0.7 15.3 11.1 0.4 0 0.4 0.4 57 4 55 305 87 1 87 0 -10.3 0 -10 -10.4 02/13/2005 13:30:00 13.7 0.5 15.3 11.8 13.6 0.6 15.3 11.5 0.4 0 0.4 0.4 63 4 58 305 85 0 86 0 -10.4 0 -10.2 -10.4 02/13/2005 13:40:00 13.1 0.8 15.6 11.1 12.9 0.9 15.3 10.7 0.4 0 0.4 0.4 62 4 64 305 84 0 84 0 -10.3 0.1 -10 -10.4 02/13/2005 13:50:00 14 0.8 16.1 12.2 13.9 0.9 16.1 11.8 0.4 0 0.4 0.4 63 3 63 305 83 0 84 0 -10.5 0 -10.2 -10.9 02/13/2005 14:00:00 13.3 0.6 15.3 11.5 13.1 0.7 14.9 11.5 0.4 0 0.4 0.4 63 3 62 305 82 0 82 0 -10.7 0 -10.4 -10.9 02/13/2005 14:10:00 13.2 0.7 14.9 10.7 12.9 0.8 14.9 10.3 0.4 0 0.4 0.4 65 4 70 305 82 0 82 0 -10.5 0 -10.4 -10.9 02/13/2005 14:20:00 12.9 0.6 14.5 11.5 12.7 0.7 14.5 10.3 0.4 0 0.4 0.4 59 4 52 305 82 0 82 0 -10.6 0 -10.4 -10.9 02/13/2005 14:30:00 12.5 0.9 14.5 9.5 12.3 1 14.5 9.5 0.4 0 0.4 0.4 56 5 55 305 82 0 82 0 -10.5 0 -10.2 -10.7 02/13/2005 14:40:00 11.9 0.7 13.7 9.5 11.7 0.9 13.3 9.1 0.4 0 0.4 0.4 51 4 50 305 83 0 83 0 -10.5 0 -10.4 -10.7 02/13/2005 14:50:00 12.1 0.6 13.7 10.3 11.8 0.8 13.3 9.5 0.4 0 0.4 0.4 51 4 46 305 83 0 84 0 -10.5 0 -10.4 -10.9 02/13/2005 15:00:00 12.6 0.7 14.5 10.3 12.4 0.8 14.9 9.5 0.4 0 0.4 0.4 54 3 54 305 83 0 84 0 -10.5 0 -10.4 -10.7 02/13/2005 15:10:00 12.2 0.7 13.7 9.9 11.8 0.8 13.7 9.5 0.4 0 0.4 0.4 53 4 56 305 84 0 84 0 -10.3 0 -10 -10.4 02/13/2005 15:20:00 12.4 0.8 14.1 10.3 12 1 14.1 9.5 0.4 0 0.4 0.4 49 4 46 305 85 0 84 0 -10.3 0 -10 -10.4 02/13/2005 15:30:00 12.4 0.7 14.1 9.9 12.2 0.9 14.1 8.8 0.4 0 0.4 0.4 48 4 48 305 86 0 86 0 -10.2 0 -10 -10.4 02/13/2005 15:40:00 11.9 0.7 13.7 9.9 11.6 0.8 13.3 9.5 0.4 0 0.4 0.4 46 5 46 305 87 0 86 0 -9.8 0 -9.6 -10 02/13/2005 15:50:00 12.2 1 14.5 9.5 12 1 14.1 9.5 0.4 0 0.4 0.4 41 7 46 305 88 0 88 0 -9.6 0.2 -9.2 -9.8 02/13/2005 16:00:00 12.5 0.9 14.5 10.3 12.3 1 14.9 8.8 0.4 0 0.4 0.4 32 5 32 305 90 0 90 0 -9.4 0 -9 -9.6 02/13/2005 16:10:00 11.8 0.8 13.7 9.1 11.6 0.9 13.3 8.4 0.4 0 0.4 0.4 38 4 47 305 91 0 91 0 -9.5 0 -9.2 -9.6 02/13/2005 16:20:00 11.6 0.7 13.7 9.5 11.4 0.8 13.3 8.4 0.4 0 0.4 0.4 32 5 25 305 91 0 91 0 -9.6 0 -9.4 -9.8 02/13/2005 16:30:00 10.8 0.7 13 8.8 10.8 0.8 13 8.4 0.4 0 0.4 0.4 31 7 24 305 92 0 92 0 -9.4 0.1 -9 -9.6 02/13/2005 16:40:00 11.1 0.8 13 8.8 11 0.8 13 8.8 0.4 0 0.4 0.4 24 5 23 305 93 0 93 0 -9.2 0 -9 -9.2 02/13/2005 16:50:00 12.3 0.8 13.7 9.1 12.3 0.9 14.1 9.5 0.4 0 0.4 0.4 19 6 17 305 94 0 94 0 -9.3 0 -9 -9.4 02/13/2005 17:00:00 12.1 0.9 14.1 9.5 12.2 1 14.1 9.1 0.4 0 0.4 0.4 20 5 15 305 94 0 94 0 -9.3 0 -9.2 -9.4 02/13/2005 17:10:00 12 1 14.9 9.5 12 1 14.9 9.1 0.4 0 0.4 0.4 24 4 25 305 94 0 94 0 -9.3 0 -9.2 -9.4 02/13/2005 17:20:00 12.5 1 14.5 9.1 12.4 1.2 15.3 8.4 0.4 0 0.4 0.4 24 5 30 305 94 0 94 0 -9.2 0 -9 -9.4 02/13/2005 17:30:00 12.4 0.9 15.3 10.3 12.4 1 14.9 9.9 0.4 0 0.4 0.4 20 5 31 305 94 0 94 0 -9.1 0 -9 -9.2 02/13/2005 17:40:00 13 0.8 14.9 10.3 13 0.8 15.3 10.7 0.4 0 0.4 0.4 22 5 22 305 94 0 94 0 -9.2 0 -8.8 -9.2 02/13/2005 17:50:00 13.1 1 15.6 10.3 12.9 1.1 15.6 9.9 0.4 0 0.4 0.4 26 5 28 305 94 0 94 0 -9.1 0 -8.8 -9.2 02/13/2005 18:00:00 12.9 0.8 16.4 10.7 12.7 0.9 15.6 9.9 0.4 0 0.4 0.4 22 4 21 305 94 0 94 0 -9.3 0 -9 -9.4 02/13/2005 18:10:00 14.9 0.8 16.8 11.8 14.7 1 16.8 11.5 0.4 0 0.4 0.4 27 4 30 305 93 1 94 0 -9.7 0.1 -9.2 -10 02/13/2005 18:20:00 13.3 1 15.6 10.3 13 1.1 15.6 10.3 0.4 0 0.4 0.4 29 5 28 305 91 0 91 0 -10 0 -9.8 -10 02/13/2005 18:30:00 13.7 1.5 16.8 10.3 13.5 1.7 17.2 9.9 0.4 0 0.4 0.4 26 5 22 305 89 0 90 0 -10.3 0.1 -10 -10.7 02/13/2005 18:40:00 11.9 1.1 14.5 9.1 11.7 1.1 14.1 8.8 0.4 0 0.4 0.4 32 5 33 305 88 0 88 0 -10.4 0 -10.4 -10.7 02/13/2005 18:50:00 11.8 1.2 14.9 8.4 11.7 1.2 14.9 8.8 0.4 0 0.4 0.4 27 5 27 305 87 0 87 0 -10.4 0 -10.2 -10.4 02/13/2005 19:00:00 11.2 1 13.3 8 11 1.2 13.7 7.2 0.4 0 0.4 0.4 30 5 21 305 86 0 87 0 -10.4 0 -10 -10.7 02/13/2005 19:10:00 12.9 1.2 15.3 9.5 12.6 1.3 15.6 9.1 0.4 0 0.4 0.4 29 6 26 305 86 0 86 0 -10.5 0.1 -10.2 -10.9 02/13/2005 19:20:00 12.8 1.1 15.3 9.9 12.5 1.2 15.3 9.5 0.4 0 0.4 0.4 30 5 30 305 85 0 84 0 -10.9 0 -10.7 -11.3 02/13/2005 19:30:00 13 1 15.3 9.9 12.9 1.1 15.3 9.5 0.4 0 0.4 0.4 36 5 27 305 83 1 84 0 -11.7 0.3 -11.3 -12.3 02/13/2005 19:40:00 12.6 1 15.3 9.5 12.4 1.1 14.5 9.1 0.4 0 0.4 0.4 31 5 48 305 81 0 82 0 -12.5 0.1 -12.1 -12.7 02/13/2005 19:50:00 11.9 1 14.5 9.1 11.8 1.1 14.1 9.1 0.4 0 0.4 0.4 35 7 31 305 79 0 80 0 -12.8 0.1 -12.5 -13.1 02/13/2005 20:00:00 11.5 0.8 13 9.1 11.2 0.9 13 8.8 0.4 0 0.4 0.4 43 5 41 305 76 0 76 0 -13.1 0 -12.5 -13.3 02/13/2005 20:10:00 10.6 1 13 7.6 10.4 1.1 12.6 8 0.4 0 0.4 0.4 37 7 29 305 75 0 76 0 -13.2 0 -12.7 -13.3 02/13/2005 20:20:00 11.8 1.2 14.5 8 11.6 1.2 14.1 9.1 0.4 0 0.4 0.4 35 5 46 305 74 0 74 0 -13.2 0.1 -12.5 -13.5 02/13/2005 20:30:00 11.4 1 13.7 8.8 11.3 1 13.7 8.4 0.4 0 0.4 0.4 34 5 33 305 73 0 73 0 -13.4 0 -12.9 -13.5 02/13/2005 20:40:00 11.7 1 13.7 9.1 11.5 1 13.7 9.1 0.4 0 0.4 0.4 28 5 24 305 73 0 73 0 -13.3 0 -12.9 -13.5 02/13/2005 20:50:00 11.5 0.8 13.3 9.1 11.3 0.9 13 9.1 0.4 0 0.4 0.4 29 5 32 305 73 0 73 0 -13.3 0 -12.9 -13.5 02/13/2005 21:00:00 11.7 1 14.1 9.1 11.6 1.1 13.7 8.8 0.4 0 0.4 0.4 28 6 27 305 73 0 73 0 -13.3 0 -12.9 -13.5 02/13/2005 21:10:00 11.8 1 13.7 9.1 11.7 1 13.7 9.1 0.4 0 0.4 0.4 28 5 30 305 73 0 73 0 -13.4 0 -13.1 -13.5 02/13/2005 21:20:00 11.1 1.1 13.7 8.4 11 1.1 13.3 8.4 0.4 0 0.4 0.4 26 6 16 305 73 0 73 0 -13.4 0 -13.1 -13.5 02/13/2005 21:30:00 11.7 0.8 13.7 9.5 11.6 0.8 13.7 9.9 0.4 0 0.4 0.4 27 4 31 305 73 0 73 0 -13.5 0 -13.3 -13.7 02/13/2005 21:40:00 11.7 1 13.7 8.8 11.5 1 14.1 8.4 0.4 0 0.4 0.4 28 4 29 305 73 0 73 0 -13.5 0 -13.3 -13.7 02/13/2005 21:50:00 11.6 0.9 13.3 9.1 11.5 1 13.7 8.8 0.4 0 0.4 0.4 26 5 27 305 73 0 73 0 -13.4 0 -13.3 -13.7 02/13/2005 22:00:00 11 0.8 13.3 8.8 11 0.9 13.7 9.1 0.4 0 0.4 0.4 25 5 25 305 73 0 74 0 -13.4 0 -13.1 -13.5 02/13/2005 22:10:00 11.1 0.9 13.3 8.8 10.8 0.9 13 8.4 0.4 0 0.4 0.4 29 5 28 305 74 0 74 0 -13.3 0 -13.3 -13.5 02/13/2005 22:20:00 10.7 1 13.3 8 10.5 1 13 8.4 0.4 0 0.4 0.4 30 5 32 305 74 0 74 0 -13.3 0 -13.1 -13.5 02/13/2005 22:30:00 11.4 0.9 13.7 8.8 11.1 1 13.7 8.8 0.4 0 0.4 0.4 26 5 26 305 75 0 74 0 -13.1 0 -12.9 -13.3 02/13/2005 22:40:00 10.3 1.1 12.6 8 10.1 1.1 12.6 7.6 0.4 0 0.4 0.4 29 5 24 305 75 0 76 0 -13 0 -12.9 -13.1 02/13/2005 22:50:00 10.6 1 13 8.4 10.4 1 13.3 8 0.4 0 0.4 0.4 33 5 41 305 76 0 76 0 -13 0 -12.9 -13.1 02/13/2005 23:00:00 11.6 1.1 14.9 9.1 11.4 1.1 14.1 8.4 0.4 0 0.4 0.4 31 6 28 305 77 0 77 0 -12.9 0 -12.7 -12.9 02/13/2005 23:10:00 10.8 1.3 14.1 7.6 10.6 1.3 13.3 6.8 0.4 0 0.4 0.4 31 5 25 305 77 0 77 0 -12.7 0 -12.5 -12.9 02/13/2005 23:20:00 9.2 0.9 11.8 6.8 9 0.9 11.8 7.2 0.4 0 0.4 0.4 31 6 26 305 78 0 78 0 -12.6 0 -12.5 -12.9 02/13/2005 23:30:00 10.1 0.8 11.8 7.6 9.9 0.8 11.8 7.6 0.4 0 0.4 0.4 27 5 37 305 79 0 79 0 -12.6 0 -12.5 -12.7 02/13/2005 23:40:00 10.6 1 13.3 8 10.5 1 13.7 8 0.4 0 0.4 0.4 30 5 19 305 79 0 79 0 -12.6 0 -12.5 -12.9 02/13/2005 23:50:00 9.7 0.9 12.2 7.2 9.4 1 12.2 7.2 0.4 0 0.4 0.4 31 5 33 305 79 0 79 0 -12.6 0 -12.5 -12.7 02/14/2005 00:00:00 9.2 0.9 11.1 7.2 9.1 1 11.5 6.5 0.4 0 0.4 0.4 27 5 30 305 80 0 80 0 -12.5 0 -12.1 -12.5 02/14/2005 00:10:00 8.9 1 11.1 6.5 8.7 1 11.1 6.5 0.4 0 0.4 0.4 27 5 31 305 80 0 81 0 -12.4 0 -12.1 -12.5 02/14/2005 00:20:00 8.8 1.2 11.5 6.1 8.6 1.3 11.5 5.7 0.4 0 0.4 0.4 27 5 28 305 81 0 81 0 -12.3 0 -12.1 -12.5 02/14/2005 00:30:00 9.5 0.8 11.1 7.2 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 29 4 29 305 81 0 81 0 -12.2 0 -12.1 -12.5 02/14/2005 00:40:00 9.4 0.9 11.8 7.2 9.1 0.9 11.5 7.2 0.4 0 0.4 0.4 27 5 32 305 82 0 82 0 -12 0 -11.9 -12.3 02/14/2005 00:50:00 9.7 0.9 12.2 7.2 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 28 5 36 305 82 0 82 0 -12 0 -11.7 -12.1 02/14/2005 01:00:00 9.6 0.7 11.8 7.6 9.4 0.7 11.5 7.2 0.4 0 0.4 0.4 25 5 23 305 83 0 83 0 -11.9 0 -11.7 -12.1 02/14/2005 01:10:00 9.6 0.9 11.5 6.8 9.4 1 11.5 6.5 0.4 0 0.4 0.4 26 5 27 305 83 0 83 0 -11.8 0 -11.7 -12.1 02/14/2005 01:20:00 8.8 1 11.1 6.1 8.7 1 11.1 6.1 0.4 0 0.4 0.4 22 7 32 305 84 0 83 0 -11.8 0 -11.7 -11.9 02/14/2005 01:30:00 8.2 0.9 10.3 5.7 8.1 0.8 10.3 6.1 0.4 0 0.4 0.4 15 5 15 305 84 0 84 0 -11.8 0 -11.7 -12.1 02/14/2005 01:40:00 8.4 0.7 10.3 6.5 8.3 0.8 9.9 6.1 0.4 0 0.4 0.4 14 4 13 305 84 0 84 0 -11.8 0 -11.7 -11.9 02/14/2005 01:50:00 8.4 0.7 9.9 6.5 8.2 0.6 10.3 6.5 0.4 0 0.4 0.4 17 4 16 305 84 0 84 0 -11.8 0 -11.7 -11.9 02/14/2005 02:00:00 7.7 0.7 9.5 5.7 7.5 0.7 9.5 5.7 0.4 0 0.4 0.4 20 5 18 305 84 0 84 0 -11.7 0 -11.5 -11.9 02/14/2005 02:10:00 7.1 0.8 9.5 5.3 7 0.8 8.8 4.9 0.4 0 0.4 0.4 22 5 13 305 84 0 84 0 -11.7 0 -11.5 -11.9 02/14/2005 02:20:00 7.5 0.9 9.9 5.7 7.4 0.9 9.9 5.3 0.4 0 0.4 0.4 21 5 23 305 84 0 84 0 -11.6 0 -11.5 -11.7 02/14/2005 02:30:00 8.1 0.7 9.9 6.1 7.9 0.8 9.9 5.7 0.4 0 0.4 0.4 22 5 23 305 85 0 85 0 -11.5 0 -11.3 -11.7 02/14/2005 02:40:00 8.2 0.8 10.3 6.1 8 0.8 10.3 6.1 0.4 0 0.4 0.4 20 5 19 305 85 0 86 0 -11.5 0 -11.3 -11.7 02/14/2005 02:50:00 8.2 0.9 10.7 5.7 8.1 0.9 10.3 5.7 0.4 0 0.4 0.4 18 5 11 305 86 0 86 0 -11.4 0 -11.3 -11.7 02/14/2005 03:00:00 8.1 0.8 10.3 5.7 8.2 0.8 9.9 5.7 0.4 0 0.4 0.4 18 5 26 305 86 0 86 0 -11.4 0 -11.1 -11.5 02/14/2005 03:10:00 8.2 0.8 10.3 6.1 8.2 0.9 10.3 5.7 0.4 0 0.4 0.4 20 5 20 305 86 0 86 0 -11.4 0 -11.1 -11.5 02/14/2005 03:20:00 8.7 0.9 10.3 6.5 8.6 0.9 10.7 6.5 0.4 0 0.4 0.4 17 5 10 305 87 0 87 0 -11.2 0 -10.9 -11.5 02/14/2005 03:30:00 9.3 1 11.1 6.5 9.1 1 11.1 6.5 0.4 0 0.4 0.4 15 4 11 305 87 0 87 0 -11.2 0 -10.9 -11.3 02/14/2005 03:40:00 9.2 0.8 11.1 6.8 9.1 0.8 11.1 6.1 0.4 0 0.4 0.4 13 6 19 305 87 0 87 0 -11.2 0 -10.9 -11.3 02/14/2005 03:50:00 9.5 1 11.5 7.2 9.4 1.1 11.5 6.8 0.4 0 0.4 0.4 11 4 13 305 87 0 87 0 -11.2 0 -10.9 -11.3 02/14/2005 04:00:00 8.6 0.8 10.3 6.5 8.4 0.8 11.1 6.1 0.4 0 0.4 0.4 13 5 9 305 87 0 87 0 -11.2 0 -10.9 -11.5 02/14/2005 04:10:00 8.2 1.1 10.3 6.1 8.1 1 10.3 6.1 0.4 0 0.4 0.4 17 4 14 305 87 0 87 0 -11.4 0 -11.1 -11.5 02/14/2005 04:20:00 7.9 0.9 9.5 5.7 7.8 0.9 9.9 5.7 0.4 0 0.4 0.4 21 4 17 305 87 0 87 0 -11.4 0 -11.3 -11.7 02/14/2005 04:30:00 8.1 0.7 9.5 6.5 8 0.7 9.5 6.5 0.4 0 0.4 0.4 20 3 20 305 86 0 86 0 -11.5 0 -11.3 -11.7 02/14/2005 04:40:00 8.2 0.7 10.3 6.5 8.1 0.8 9.9 6.5 0.4 0 0.4 0.4 20 4 18 305 86 0 86 0 -11.5 0 -11.3 -11.7 02/14/2005 04:50:00 8 0.8 9.9 6.1 7.9 0.8 9.5 5.7 0.4 0 0.4 0.4 18 5 18 305 86 0 86 0 -11.5 0 -11.3 -11.7 02/14/2005 05:00:00 8.4 0.8 10.3 6.1 8.2 0.9 10.3 5.7 0.4 0 0.4 0.4 17 4 17 305 85 0 85 0 -11.6 0 -11.3 -11.9 02/14/2005 05:10:00 8.2 0.7 9.9 6.8 8.1 0.7 9.9 6.1 0.4 0 0.4 0.4 14 4 9 305 85 0 85 0 -11.7 0 -11.5 -11.9 02/14/2005 05:20:00 8.2 0.7 9.9 6.5 8 0.8 9.5 6.1 0.4 0 0.4 0.4 17 4 20 305 85 0 85 0 -11.7 0 -11.5 -11.9 02/14/2005 05:30:00 7.8 0.9 9.9 5.7 7.6 0.9 9.5 5.7 0.4 0 0.4 0.4 18 4 14 305 84 0 85 0 -11.7 0 -11.5 -11.9 02/14/2005 05:40:00 7.9 0.7 9.1 6.1 7.7 0.7 9.1 5.7 0.4 0 0.4 0.4 17 5 18 305 84 0 84 0 -11.6 0 -11.5 -11.9 02/14/2005 05:50:00 7.6 0.7 9.1 6.1 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 12 4 15 305 84 0 84 0 -11.8 0 -11.5 -12.1 02/14/2005 06:00:00 8.4 0.8 10.3 6.5 8.2 0.8 10.7 6.1 0.4 0 0.4 0.4 14 4 11 305 84 0 85 0 -11.8 0 -11.5 -12.1 02/14/2005 06:10:00 7.7 0.7 9.9 6.1 7.6 0.8 9.9 5.7 0.4 0 0.4 0.4 15 4 16 305 84 0 84 0 -11.9 0 -11.7 -12.1 02/14/2005 06:20:00 8 0.6 9.5 6.1 7.9 0.7 9.1 5.7 0.4 0 0.4 0.4 17 5 10 305 84 0 84 0 -11.9 0 -11.7 -12.1 02/14/2005 06:30:00 8.2 0.7 9.5 6.1 8 0.7 9.9 6.1 0.4 0 0.4 0.4 21 4 21 305 84 0 84 0 -11.9 0 -11.7 -12.1 02/14/2005 06:40:00 8.5 0.6 9.9 6.8 8.3 0.7 9.9 6.8 0.4 0 0.4 0.4 20 4 19 305 84 0 84 0 -12 0 -11.7 -12.1 02/14/2005 06:50:00 8.7 0.8 9.9 6.1 8.6 0.8 9.9 6.1 0.4 0 0.4 0.4 12 4 6 305 84 0 84 0 -11.9 0 -11.7 -12.1 02/14/2005 07:00:00 8.5 0.6 9.9 6.8 8.5 0.6 9.9 7.2 0.4 0 0.4 0.4 14 3 18 305 84 0 84 0 -12 0 -11.7 -12.1 02/14/2005 07:10:00 8 0.6 9.5 5.7 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 24 9 13 305 84 0 84 0 -12.2 0.2 -11.9 -12.5 02/14/2005 07:20:00 7.8 0.7 9.5 6.1 7.7 0.7 9.5 5.7 0.4 0 0.4 0.4 28 5 38 305 83 0 83 0 -12.6 0 -12.3 -12.7 02/14/2005 07:30:00 7.9 0.6 9.5 6.5 7.9 0.6 9.5 6.1 0.4 0 0.4 0.4 23 4 33 305 82 0 82 0 -12.6 0 -12.3 -12.7 02/14/2005 07:40:00 8.1 0.7 9.5 6.1 7.9 0.7 9.1 6.1 0.4 0 0.4 0.4 35 4 36 305 82 0 82 0 -12.6 0 -12.3 -12.7 02/14/2005 07:50:00 8.5 0.7 10.7 6.5 8.4 0.7 10.3 6.8 0.4 0 0.4 0.4 31 5 38 305 81 0 82 0 -12.6 0 -12.5 -12.7 02/14/2005 08:00:00 9 0.8 10.7 6.5 9 0.9 10.7 6.5 0.4 0 0.4 0.4 22 4 19 305 81 0 82 0 -12.6 0 -12.5 -12.9 02/14/2005 08:10:00 9.6 0.8 11.1 7.2 9.5 0.9 11.1 7.2 0.4 0 0.4 0.4 21 4 21 305 81 0 82 0 -12.8 0 -12.5 -12.9 02/14/2005 08:20:00 9.5 0.9 11.5 6.8 9.5 0.9 11.8 7.2 0.4 0 0.4 0.4 19 4 19 305 81 0 81 0 -12.7 0 -12.5 -12.9 02/14/2005 08:30:00 9.9 0.8 11.1 6.8 9.8 0.9 11.5 6.8 0.4 0 0.4 0.4 20 5 14 305 81 0 82 0 -12.7 0 -12.5 -12.9 02/14/2005 08:40:00 10.6 1 12.6 8 10.6 1 12.6 7.6 0.4 0 0.4 0.4 9 6 5 305 81 0 82 0 -13 0.3 -12.5 -13.5 02/14/2005 08:50:00 11.4 0.7 12.6 9.5 11.4 0.8 13 9.1 0.4 0 0.4 0.4 10 3 8 305 80 0 80 0 -13.4 0.1 -13.1 -13.7 02/14/2005 09:00:00 12 1 13.7 8.8 12 1 13.7 8.8 0.4 0 0.4 0.4 13 4 11 305 79 0 78 0 -13.7 0 -13.3 -13.9 02/14/2005 09:10:00 11.8 0.9 13.3 9.5 11.8 0.9 13.7 9.5 0.4 0 0.4 0.4 17 5 8 305 77 0 77 0 -13.8 0 -13.7 -13.9 02/14/2005 09:20:00 11.8 1 13.7 9.1 11.8 1.1 13.7 8.8 0.4 0 0.4 0.4 27 6 16 305 77 0 77 0 -13.9 0 -13.7 -14.1 02/14/2005 09:30:00 11.8 0.7 13.3 9.5 11.5 0.8 13 9.1 0.4 0 0.4 0.4 30 3 33 305 76 0 76 0 -14.1 0 -13.7 -14.3 02/14/2005 09:40:00 10.4 1.1 12.6 7.2 10.2 1 12.6 7.2 0.4 0 0.4 0.4 28 6 42 305 75 0 76 0 -14.1 0 -13.7 -14.3 02/14/2005 09:50:00 11.3 0.8 13.3 8.8 11.3 0.9 13 9.1 0.4 0 0.4 0.4 19 4 12 305 75 0 76 0 -14.2 0 -13.9 -14.3 02/14/2005 10:00:00 11.6 0.7 13.3 9.5 11.5 0.8 13 9.1 0.4 0 0.4 0.4 23 5 25 305 75 0 75 0 -14.2 0 -14.1 -14.3 02/14/2005 10:10:00 11.4 0.8 13.3 9.1 11.3 0.9 13 9.1 0.4 0 0.4 0.4 28 5 30 305 74 0 75 0 -14.3 0 -14.3 -14.4 02/14/2005 10:20:00 10.9 1.1 12.6 8 10.7 1.1 13 7.2 0.4 0 0.4 0.4 24 5 28 305 74 0 74 0 -14.3 0 -14.3 -14.4 02/14/2005 10:30:00 11.1 1 13 8.4 11 1 13 8 0.4 0 0.4 0.4 25 5 21 305 74 0 74 0 -14.4 0 -14.3 -14.4 02/14/2005 10:40:00 11.1 0.8 13 8.4 10.9 0.9 13.3 8 0.4 0 0.4 0.4 22 5 19 305 74 0 74 0 -14.3 0 -14.3 -14.6 02/14/2005 10:50:00 10.2 1.1 12.2 6.8 10.1 1.2 12.6 6.5 0.4 0 0.4 0.4 24 5 29 305 74 0 74 0 -14.3 0 -14.3 -14.6 02/14/2005 11:00:00 9.3 1.2 11.8 6.5 9.3 1.2 11.8 6.1 0.4 0 0.4 0.4 24 5 24 305 74 0 74 0 -14.3 0 -14.1 -14.4 02/14/2005 11:10:00 10.1 1.2 12.2 6.8 9.9 1.1 12.2 7.2 0.4 0 0.4 0.4 19 5 12 305 75 0 75 0 -14.4 0 -14.1 -14.6 02/14/2005 11:20:00 9.9 1.1 11.8 6.8 9.8 1.1 11.8 6.8 0.4 0 0.4 0.4 21 5 19 305 74 0 74 0 -14.4 0 -14.3 -14.6 02/14/2005 11:30:00 10.3 1.2 12.6 7.6 10.2 1.2 12.6 7.2 0.4 0 0.4 0.4 20 5 16 305 74 0 74 0 -14.5 0 -14.3 -14.6 02/14/2005 11:40:00 11.1 1 13.3 8 11 1.1 13.7 8 0.4 0 0.4 0.4 23 5 20 305 74 0 74 0 -14.6 0 -14.3 -14.6 02/14/2005 11:50:00 10.5 1 12.6 8 10.5 1.1 12.6 8 0.4 0 0.4 0.4 22 6 18 305 74 0 74 0 -14.7 0 -14.6 -14.8 02/14/2005 12:00:00 10.3 0.8 12.2 8 10.2 0.8 12.2 7.6 0.4 0 0.4 0.4 22 5 19 305 73 0 73 0 -14.8 0 -14.6 -15 02/14/2005 12:10:00 9 1 12.2 6.5 9 1 11.5 6.8 0.4 0 0.4 0.4 19 5 21 305 73 0 73 0 -14.8 0 -14.6 -15 02/14/2005 12:20:00 10 1 12.6 7.2 9.8 1 12.2 7.6 0.4 0 0.4 0.4 20 5 13 305 73 0 74 0 -15 0 -14.6 -15 02/14/2005 12:30:00 10 1 12.6 7.6 9.9 1 12.2 7.6 0.4 0 0.4 0.4 18 5 27 305 73 0 73 0 -15.1 0 -14.8 -15.2 02/14/2005 12:40:00 11.3 1.1 14.1 8 11.3 1.1 13.7 6.8 0.4 0 0.4 0.4 20 5 19 305 73 0 72 0 -15.5 0.1 -15 -15.8 02/14/2005 12:50:00 11.6 1.3 14.1 7.6 11.4 1.3 14.5 8 0.4 0 0.4 0.4 19 5 9 305 71 0 71 0 -15.8 0 -15.6 -15.8 02/14/2005 13:00:00 11.7 1.2 14.5 8.8 11.6 1.2 14.5 8 0.4 0 0.4 0.4 19 5 17 305 70 0 71 0 -15.8 0 -15.4 -16 02/14/2005 13:10:00 11.5 1.3 14.5 8 11.4 1.3 14.1 7.6 0.4 0 0.4 0.4 16 5 14 305 70 0 70 0 -15.8 0 -15.6 -15.8 02/14/2005 13:20:00 12.2 1.2 15.6 9.1 12 1.2 14.9 8.8 0.4 0 0.4 0.4 17 5 17 305 70 0 70 0 -15.8 0 -15.6 -16 02/14/2005 13:30:00 12.1 1.3 14.5 8.4 12 1.2 14.5 8.4 0.4 0 0.4 0.4 19 5 23 305 70 0 70 0 -15.8 0 -15.6 -16 02/14/2005 13:40:00 11.9 1.2 13.7 8 11.8 1.2 14.5 8.4 0.4 0 0.4 0.4 20 6 17 305 69 0 69 0 -15.8 0 -15.6 -16 02/14/2005 13:50:00 12.7 1.3 15.6 9.1 12.6 1.3 15.3 9.5 0.4 0 0.4 0.4 22 6 20 305 69 0 69 0 -15.8 0 -15.6 -16 02/14/2005 14:00:00 13.7 1.1 16.1 9.9 13.5 1.1 16.4 10.3 0.4 0 0.4 0.4 24 6 19 305 69 0 69 0 -15.8 0 -15.6 -16 02/14/2005 14:10:00 13.3 1.3 16.4 9.9 13 1.3 16.1 9.5 0.4 0 0.4 0.4 26 5 25 305 69 0 69 0 -15.8 0 -15.6 -16 02/14/2005 14:20:00 13.3 1.4 16.1 9.5 13.1 1.4 16.1 9.9 0.4 0 0.4 0.4 26 5 23 305 69 0 69 0 -15.8 0 -15.6 -16 02/14/2005 14:30:00 13.6 1.3 16.4 9.9 13.4 1.2 16.1 9.5 0.4 0 0.4 0.4 27 5 28 305 70 0 69 0 -15.8 0 -15.6 -16 02/14/2005 14:40:00 13.2 1.7 16.1 8 13 1.7 16.1 8 0.4 0 0.4 0.4 24 6 23 305 70 0 70 0 -15.8 0 -15.6 -16 02/14/2005 14:50:00 13.2 1.5 16.8 9.1 12.9 1.5 16.1 9.1 0.4 0 0.4 0.4 22 6 17 305 70 0 70 0 -15.9 0 -15.6 -16 02/14/2005 15:00:00 12.8 1.7 16.8 8.4 12.4 1.7 16.8 9.1 0.4 0 0.4 0.4 20 5 21 305 69 0 69 0 -15.9 0 -15.8 -16.2 02/14/2005 15:10:00 13.5 1.4 16.4 9.9 13.3 1.4 16.4 9.5 0.4 0 0.4 0.4 21 5 23 305 69 0 69 0 -15.9 0 -15.6 -16 02/14/2005 15:20:00 12.7 1.7 16.1 8.4 12.7 1.6 16.4 8.4 0.4 0 0.4 0.4 20 5 20 305 69 0 69 0 -15.9 0 -15.6 -16.2 02/14/2005 15:30:00 13.6 1.1 16.1 10.7 13.5 1.2 16.4 10.3 0.4 0 0.4 0.4 21 4 23 305 69 0 69 0 -16 0 -15.8 -16.2 02/14/2005 15:40:00 13.2 1 15.6 10.7 13 1.1 16.1 10.7 0.4 0 0.4 0.4 19 6 21 305 69 0 68 0 -16 0 -15.8 -16.2 02/14/2005 15:50:00 13.3 1.2 15.6 10.3 13.1 1.1 16.1 10.3 0.4 0 0.4 0.4 22 6 22 305 69 0 68 0 -15.9 0 -15.8 -16 02/14/2005 16:00:00 13.8 1.5 17.2 9.9 13.5 1.4 16.8 10.3 0.4 0 0.4 0.4 24 5 17 305 69 0 69 0 -15.8 0 -15.6 -16 02/14/2005 16:10:00 12.1 1.5 15.3 8 11.8 1.6 15.3 8 0.4 0 0.4 0.4 23 7 29 305 69 0 69 0 -15.6 0.1 -15.2 -15.8 02/14/2005 16:20:00 11.9 1.4 14.9 8.4 11.9 1.3 14.5 8 0.4 0 0.4 0.4 19 5 18 305 70 0 70 0 -15.7 0 -15.6 -15.8 02/14/2005 16:30:00 12.9 1.2 15.3 9.9 12.8 1.1 14.9 9.9 0.4 0 0.4 0.4 18 6 15 305 70 0 70 0 -15.8 0 -15.6 -16 02/14/2005 16:40:00 12.3 1.1 14.9 9.5 12.3 1.1 14.9 9.5 0.4 0 0.4 0.4 18 7 15 305 69 0 70 0 -15.8 0 -15.6 -16 02/14/2005 16:50:00 12.7 1.2 15.6 10.3 12.7 1.3 15.6 9.1 0.4 0 0.4 0.4 17 6 18 305 69 0 69 0 -15.9 0 -15.6 -16 02/14/2005 17:00:00 12.9 1.2 15.6 9.5 12.8 1.2 15.3 9.9 0.4 0 0.4 0.4 22 5 23 305 69 0 69 0 -15.9 0 -15.8 -16 02/14/2005 17:10:00 13.5 1.2 17.6 10.3 13.4 1.1 15.6 10.7 0.4 0 0.4 0.4 20 5 22 305 68 0 68 0 -15.9 0 -15.8 -16.2 02/14/2005 17:20:00 13.8 1.3 16.8 9.9 13.7 1.4 16.4 9.9 0.4 0 0.4 0.4 20 5 16 305 68 0 68 0 -16 0 -15.8 -16.2 02/14/2005 17:30:00 12.8 1.4 16.8 9.1 12.7 1.3 16.8 8.8 0.4 0 0.4 0.4 19 5 27 305 68 0 68 0 -15.9 0 -15.6 -16.2 02/14/2005 17:40:00 12.8 1.7 16.8 9.1 12.7 1.6 16.4 9.1 0.4 0 0.4 0.4 21 5 19 305 68 0 68 0 -15.8 0 -15.6 -16 02/14/2005 17:50:00 11.7 1.1 14.5 9.5 11.6 1 14.1 9.1 0.4 0 0.4 0.4 17 6 20 305 68 0 69 0 -15.7 0.1 -15.6 -15.8 02/14/2005 18:00:00 12.4 1 14.5 9.5 12.4 1 14.9 9.9 0.4 0 0.4 0.4 9 5 4 305 69 0 69 0 -15.8 0 -15.4 -16 02/14/2005 18:10:00 11.9 1.3 14.9 8.8 11.9 1.2 14.9 8.8 0.4 0 0.4 0.4 9 5 12 305 68 0 69 0 -15.8 0 -15.6 -16 02/14/2005 18:20:00 11.8 1.2 15.3 9.1 11.8 1.3 14.9 8 0.4 0 0.4 0.4 8 5 11 305 68 0 68 0 -15.8 0 -15.6 -16 02/14/2005 18:30:00 12.3 1.2 15.6 8.4 12.2 1.1 14.9 9.1 0.4 0 0.4 0.4 12 7 8 305 68 0 68 0 -15.8 0 -15.6 -16 02/14/2005 18:40:00 11.2 1.3 13.3 7.6 11.1 1.3 13.7 7.2 0.4 0 0.4 0.4 10 7 12 305 68 0 68 0 -15.8 0 -15.6 -15.8 02/14/2005 18:50:00 10.6 1.4 14.1 7.2 10.5 1.3 13.7 7.6 0.4 0 0.4 0.4 9 6 18 305 68 0 68 0 -15.8 0 -15.6 -16 02/14/2005 19:00:00 10.8 1.4 14.1 7.6 10.8 1.3 13.7 7.6 0.4 0 0.4 0.4 9 6 6 305 68 0 68 0 -15.8 0 -15.6 -16 02/14/2005 19:10:00 11.1 1.5 14.5 6.8 10.9 1.5 14.5 7.2 0.4 0 0.4 0.4 9 5 5 305 68 0 68 0 -15.7 0.1 -15.4 -15.8 02/14/2005 19:20:00 10.4 1.3 14.1 8 10.3 1.3 14.1 7.2 0.4 0 0.4 0.4 8 6 2 305 69 0 69 0 -15.5 0 -15.2 -15.8 02/14/2005 19:30:00 11.4 1.2 14.9 8.8 11.4 1.3 15.3 8.4 0.4 0 0.4 0.4 7 5 2 305 69 0 69 0 -15.4 0 -15 -15.6 02/14/2005 19:40:00 9.8 1.2 12.6 6.8 9.9 1.3 13 6.8 0.4 0 0.4 0.4 7 6 1 305 70 0 70 0 -15.3 0 -15 -15.4 02/14/2005 19:50:00 10.7 1.2 14.1 7.6 10.7 1.2 14.1 7.2 0.4 0 0.4 0.4 5 5 10 305 70 0 70 0 -15.2 0 -14.8 -15.2 02/14/2005 20:00:00 9.6 1.3 13 6.1 9.7 1.3 13.7 6.5 0.4 0 0.4 0.4 3 6 11 305 71 0 70 0 -15 0 -14.6 -15.2 02/14/2005 20:10:00 11.1 1.5 13.7 6.8 11 1.7 13.7 6.8 0.4 0 0.4 0.4 2 5 359 305 71 0 72 0 -14.9 0 -14.6 -15 02/14/2005 20:20:00 10 0.9 12.6 7.2 9.8 1 12.6 7.2 0.4 0 0.4 0.4 6 5 5 305 72 0 72 0 -14.7 0.1 -14.4 -15 02/14/2005 20:30:00 9.3 0.9 11.1 6.8 9.2 0.9 11.5 6.5 0.4 0 0.4 0.4 8 4 7 305 73 0 73 0 -14.7 0 -14.4 -14.6 02/14/2005 20:40:00 7.9 0.6 9.1 6.1 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 8 4 10 305 73 0 73 0 -14.5 0.1 -14.3 -14.6 02/14/2005 20:50:00 7.9 1 10.7 5.3 8 1 11.1 5.7 0.4 0 0.4 0.4 2 7 1 305 74 0 75 0 -14.1 0.1 -13.7 -14.4 02/14/2005 21:00:00 9.8 1.2 12.2 6.5 9.8 1.2 12.2 6.8 0.4 0 0.4 0.4 358 9 0 305 75 0 76 0 -13.8 0 -13.5 -14.1 02/14/2005 21:10:00 9.7 1 11.8 7.2 9.7 1 11.8 7.6 0.4 0 0.4 0.4 0 4 355 305 77 0 76 0 -13.7 0 -13.5 -13.9 02/14/2005 21:20:00 8.5 0.8 10.7 6.8 8.6 0.8 11.1 6.8 0.4 0 0.4 0.4 0 5 359 305 77 0 77 0 -13.6 0 -13.3 -13.7 02/14/2005 21:30:00 8.8 0.7 10.7 6.5 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 355 5 355 305 78 0 78 0 -13.4 0 -12.9 -13.7 02/14/2005 21:40:00 7.5 0.8 9.1 5.3 7.6 0.8 9.1 5.7 0.4 0 0.4 0.4 349 6 344 305 79 0 78 0 -13.1 0 -12.9 -13.3 02/14/2005 21:50:00 8.1 1 10.7 4.9 8.2 1 10.7 5.7 0.4 0 0.4 0.4 346 6 340 305 80 0 80 0 -12.9 0 -12.5 -13.1 02/14/2005 22:00:00 8.3 0.8 9.9 5.3 8.4 0.9 9.9 5.7 0.4 0 0.4 0.4 353 4 354 305 80 0 80 0 -12.7 0 -12.5 -12.9 02/14/2005 22:10:00 6.8 1 9.1 4.6 6.9 1 9.5 4.9 0.4 0 0.4 0.4 355 5 354 305 81 0 81 0 -12.6 0 -12.1 -12.9 02/14/2005 22:20:00 6 0.8 8 3.8 6 0.8 8 4.2 0.4 0 0.4 0.4 352 5 357 305 82 0 82 0 -12.5 0 -12.1 -12.5 02/14/2005 22:30:00 5 0.6 6.5 3.8 5.1 0.6 6.5 3.4 0.4 0 0.4 0.4 352 5 356 305 82 0 82 0 -12.5 0 -12.1 -12.7 02/14/2005 22:40:00 4.1 0.5 5.3 3 4.2 0.5 5.3 3.4 0.4 0 0.4 0.4 352 4 351 305 82 0 82 0 -12.6 0 -12.3 -12.7 02/14/2005 22:50:00 3.8 0.5 4.9 2.3 3.9 0.5 4.9 2.6 0.4 0 0.4 0.4 352 4 354 305 83 0 82 0 -12.6 0 -12.1 -12.7 02/14/2005 23:00:00 2.5 0.4 3.8 1.5 2.6 0.4 3.8 1.5 0.4 0 0.4 0.4 350 5 355 305 83 0 83 0 -12.4 0.1 -12.1 -12.5 02/14/2005 23:10:00 2.4 0.6 4.2 1.5 2.4 0.4 4.2 1.9 0.4 0 0.4 0.4 333 15 307 305 83 0 82 0 -12.3 0 -11.9 -12.5 02/14/2005 23:20:00 3.5 0.5 4.6 2.3 3.3 0.5 4.6 2.3 0.4 0 0.4 0.4 310 12 306 305 83 0 83 0 -11.9 0.1 -11.5 -12.1 02/14/2005 23:30:00 3.7 0.9 5.7 2.3 3.4 0.7 5.3 2.3 0.4 0 0.4 0.4 306 20 278 305 83 0 84 0 -11.8 0.1 -11.5 -12.1 02/14/2005 23:40:00 4.7 0.6 6.1 3.4 4.2 0.6 5.7 3 0.4 0 0.4 0.4 297 12 292 305 84 0 84 0 -11.7 0 -11.5 -11.9 02/14/2005 23:50:00 4.6 0.5 5.7 3.4 4.1 0.5 5.3 2.6 0.4 0 0.4 0.4 296 8 294 305 84 0 84 0 -11.6 0 -11.3 -11.9 02/15/2005 00:00:00 4.6 0.5 6.1 3.4 4.2 0.5 5.7 2.6 0.4 0 0.4 0.4 300 15 302 305 85 0 85 0 -11.4 0 -11.1 -11.7 02/15/2005 00:10:00 5.4 0.6 6.8 3.8 4.9 0.5 6.1 3.4 0.4 0 0.4 0.4 301 15 302 305 85 0 86 0 -11.4 0 -10.9 -11.5 02/15/2005 00:20:00 5.4 0.7 6.8 3.8 4.8 0.7 6.1 3 0.4 0 0.4 0.4 294 10 305 305 86 0 86 0 -11.4 0 -10.9 -11.5 02/15/2005 00:30:00 6 0.7 7.6 3.8 5 0.7 6.5 2.6 0.4 0 0.4 0.4 284 5 291 305 86 0 86 0 -11.5 0 -10.9 -11.5 02/15/2005 00:40:00 5.8 0.9 7.2 3.4 4.8 1 6.5 2.6 0.4 0 0.4 0.4 282 9 283 305 86 0 86 0 -11.5 0 -11.3 -11.7 02/15/2005 00:50:00 5.1 0.5 6.5 3.8 3.5 0.4 4.6 2.3 0.4 0 0.4 0.4 265 5 268 305 86 0 86 0 -11.8 0.2 -11.5 -12.1 02/15/2005 01:00:00 4.5 0.5 6.1 3 3.1 0.4 4.2 2.3 0.4 0 0.4 0.4 268 6 272 305 86 0 86 0 -11.9 0.1 -11.5 -12.1 02/15/2005 01:10:00 4.3 0.6 5.7 1.9 2.9 0.5 4.2 1.5 0.4 0 0.4 0.4 265 5 264 305 86 0 86 0 -11.8 0.1 -11.5 -12.1 02/15/2005 01:20:00 4.2 0.4 5.3 3 3.3 0.5 4.6 1.5 0.4 0 0.4 0.4 258 5 254 305 86 0 86 0 -11.8 0.1 -11.5 -12.1 02/15/2005 01:30:00 4.1 0.6 5.7 2.3 3.3 0.6 4.9 1.9 0.4 0 0.4 0.4 254 7 262 305 86 0 86 0 -11.8 0 -11.5 -12.1 02/15/2005 01:40:00 4 0.6 5.3 2.6 3.6 0.6 4.9 1.9 0.4 0 0.4 0.4 248 5 249 305 86 0 86 0 -11.8 0 -11.5 -11.9 02/15/2005 01:50:00 4.9 0.6 6.1 3 4.4 0.7 6.1 2.6 0.4 0 0.4 0.4 247 5 248 305 86 0 86 0 -11.9 0 -11.7 -12.1 02/15/2005 02:00:00 4.3 0.5 5.7 3 4 0.5 5.3 3 0.4 0 0.4 0.4 238 9 247 305 86 0 86 0 -11.8 0 -11.5 -12.1 02/15/2005 02:10:00 4.4 0.4 5.3 3 4.2 0.5 5.3 3 0.4 0 0.4 0.4 228 5 227 305 86 0 86 0 -11.8 0 -11.5 -11.9 02/15/2005 02:20:00 4.4 0.5 5.7 3 4.3 0.5 5.7 3 0.4 0 0.4 0.4 225 4 227 305 86 0 86 0 -11.7 0 -11.3 -11.9 02/15/2005 02:30:00 5 0.5 5.7 3.4 4.7 0.5 5.7 3.4 0.4 0 0.4 0.4 232 6 225 305 86 0 87 0 -11.7 0 -11.5 -11.9 02/15/2005 02:40:00 5.9 0.8 7.2 4.2 5.6 0.9 7.2 3.8 0.4 0 0.4 0.4 232 6 229 305 87 0 87 0 -11.8 0.1 -11.5 -12.1 02/15/2005 02:50:00 5.3 0.5 6.5 4.2 5.1 0.4 6.1 3.8 0.4 0 0.4 0.4 233 4 237 305 86 0 86 0 -12.2 0.1 -11.7 -12.5 02/15/2005 03:00:00 5.4 0.5 6.5 4.2 5.1 0.6 6.5 3.4 0.4 0 0.4 0.4 231 4 229 305 85 0 85 0 -12.4 0.1 -12.1 -12.5 02/15/2005 03:10:00 5.2 0.5 6.5 3.4 4.9 0.6 6.5 3.4 0.4 0 0.4 0.4 227 4 227 305 84 0 85 0 -12.5 0 -12.1 -12.5 02/15/2005 03:20:00 5.1 0.3 5.7 3.8 4.9 0.4 5.7 3.8 0.4 0 0.4 0.4 221 4 225 305 84 0 84 0 -12.5 0 -12.1 -12.5 02/15/2005 03:30:00 4.8 0.5 6.1 3.4 4.7 0.5 6.1 3.4 0.4 0 0.4 0.4 222 5 223 305 83 0 83 0 -12.5 0 -12.1 -12.5 02/15/2005 03:40:00 6.5 0.6 8 4.6 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 229 5 229 305 83 0 83 0 -12.4 0.1 -12.1 -12.5 02/15/2005 03:50:00 6.4 0.7 7.6 4.2 5.9 0.8 7.6 3.8 0.4 0 0.4 0.4 234 5 227 305 83 0 83 0 -12.6 0 -12.1 -12.9 02/15/2005 04:00:00 6.3 0.6 7.6 4.2 5.9 0.7 7.2 3.8 0.4 0 0.4 0.4 234 5 231 305 83 0 83 0 -12.9 0.1 -12.5 -13.1 02/15/2005 04:10:00 6.7 0.5 8 5.3 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 237 4 229 305 82 0 81 0 -13.2 0.1 -12.7 -13.5 02/15/2005 04:20:00 6.4 0.8 8.4 4.6 6 0.8 8 4.2 0.4 0 0.4 0.4 227 5 225 305 80 0 81 0 -13.6 0 -13.1 -13.7 02/15/2005 04:30:00 6.7 0.7 8.4 4.6 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 226 5 224 305 79 0 79 0 -13.8 0 -13.5 -14.1 02/15/2005 04:40:00 7.5 0.8 9.1 5.3 6.9 0.8 9.5 4.6 0.4 0 0.4 0.4 226 5 215 305 78 0 77 0 -14.4 0.2 -13.7 -14.6 02/15/2005 04:50:00 8.5 0.6 10.3 6.8 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 232 5 248 305 76 1 76 0 -15.1 0.2 -14.6 -15.2 02/15/2005 05:00:00 7.6 0.5 9.5 6.5 6.8 0.5 8.8 5.3 0.4 0 0.4 0.4 234 4 238 305 73 1 74 0 -15.5 0.1 -15 -15.6 02/15/2005 05:10:00 7.1 0.4 8.4 6.1 6.6 0.5 7.6 4.9 0.4 0 0.4 0.4 231 4 236 305 71 1 72 0 -15.7 0 -15.6 -15.8 02/15/2005 05:20:00 6.3 0.5 7.6 4.9 5.8 0.6 7.2 4.2 0.4 0 0.4 0.4 233 4 230 305 69 0 70 0 -15.7 0 -15.6 -15.8 02/15/2005 05:30:00 7.9 1.5 11.5 5.7 7.2 1.3 10.7 4.9 0.4 0 0.4 0.4 235 5 234 305 68 0 67 0 -15.8 0 -15.6 -15.8 02/15/2005 05:40:00 9.6 0.7 11.8 7.6 8.6 0.9 11.1 6.5 0.4 0 0.4 0.4 236 5 246 305 66 0 66 0 -15.8 0 -15.6 -15.8 02/15/2005 05:50:00 9.7 0.7 11.1 8 8.8 0.8 10.7 6.8 0.4 0 0.4 0.4 236 4 235 305 66 0 66 0 -15.8 0 -15.6 -15.8 02/15/2005 06:00:00 8.3 0.8 10.3 6.5 7.5 0.8 9.9 5.3 0.4 0 0.4 0.4 236 4 245 305 65 0 65 0 -15.8 0 -15.6 -16 02/15/2005 06:10:00 9.6 0.8 11.5 7.6 8.5 0.9 11.1 6.1 0.4 0 0.4 0.4 237 4 239 305 65 0 65 0 -15.8 0 -15.6 -15.8 02/15/2005 06:20:00 9.6 1 11.8 7.2 8.6 1 10.7 6.1 0.4 0 0.4 0.4 240 5 250 305 64 0 64 0 -15.8 0 -15.6 -16 02/15/2005 06:30:00 9.8 1 11.8 6.5 8.7 1.1 11.1 5.7 0.4 0 0.4 0.4 239 5 244 305 64 0 64 0 -15.8 0 -15.6 -16 02/15/2005 06:40:00 9.7 1 12.2 7.2 8.6 1 11.5 6.1 0.4 0 0.4 0.4 235 5 241 305 64 0 64 0 -15.8 0 -15.6 -16 02/15/2005 06:50:00 10.9 0.9 13 8 9.5 1 11.8 7.2 0.4 0 0.4 0.4 236 5 232 305 64 0 64 0 -15.8 0 -15.6 -16 02/15/2005 07:00:00 9.8 1 11.8 6.8 8.7 0.9 11.1 6.1 0.4 0 0.4 0.4 235 5 242 305 64 0 64 0 -15.8 0 -15.6 -16 02/15/2005 07:10:00 8.5 0.9 10.7 6.5 7.8 0.9 9.9 5.7 0.4 0 0.4 0.4 233 5 238 305 64 0 64 0 -15.8 0 -15.6 -16 02/15/2005 07:20:00 9.8 0.9 12.2 7.2 8.9 1 11.5 5.3 0.4 0 0.4 0.4 234 5 230 305 64 0 64 0 -15.8 0 -15.6 -16 02/15/2005 07:30:00 10.3 0.9 12.6 7.6 9.4 1 11.5 6.5 0.4 0 0.4 0.4 233 4 234 305 64 0 64 0 -15.8 0 -15.6 -16 02/15/2005 07:40:00 11.3 0.8 13 8.4 10.1 1 12.2 7.2 0.4 0 0.4 0.4 235 4 237 305 64 0 64 0 -15.8 0 -15.6 -16 02/15/2005 07:50:00 11.3 0.7 13 8.8 10.1 1 12.6 7.6 0.4 0 0.4 0.4 234 4 228 305 63 0 64 0 -15.8 0 -15.6 -16 02/15/2005 08:00:00 10.1 0.8 12.2 8.4 9.1 0.9 11.1 6.8 0.4 0 0.4 0.4 234 4 237 305 63 0 64 0 -15.8 0 -15.6 -15.8 02/15/2005 08:10:00 10.5 1 12.6 8.4 9.6 1 11.8 6.8 0.4 0 0.4 0.4 233 4 234 305 63 0 63 0 -15.8 0 -15.6 -16 02/15/2005 08:20:00 11.1 0.7 13.3 9.1 9.9 0.9 11.8 7.6 0.4 0 0.4 0.4 236 4 231 305 63 0 63 0 -15.9 0 -15.6 -16 02/15/2005 08:30:00 10 0.8 12.2 8 9.1 0.8 11.5 6.8 0.4 0 0.4 0.4 234 4 229 305 63 0 63 0 -15.9 0 -15.8 -16 02/15/2005 08:40:00 10 0.6 11.5 8.4 9.4 0.7 10.7 7.2 0.4 0 0.4 0.4 231 3 225 305 63 0 63 0 -16 0 -15.8 -16.2 02/15/2005 08:50:00 9.4 0.8 11.5 6.8 8.7 0.9 10.7 6.1 0.4 0 0.4 0.4 230 3 230 305 62 0 63 0 -16.1 0.1 -15.8 -16.4 02/15/2005 09:00:00 8.8 0.6 10.3 6.5 7.9 0.7 9.5 5.3 0.4 0 0.4 0.4 227 4 233 305 62 0 62 0 -16.3 0 -16 -16.4 02/15/2005 09:10:00 8.6 0.6 9.9 6.5 7.8 0.8 9.5 5.7 0.4 0 0.4 0.4 226 4 222 305 61 0 61 0 -16.4 0 -16.4 -16.6 02/15/2005 09:20:00 8.4 0.5 10.3 6.8 7.7 0.7 9.5 6.1 0.4 0 0.4 0.4 228 3 227 305 61 0 61 0 -16.4 0 -16.4 -16.6 02/15/2005 09:30:00 8.3 0.5 10.3 6.5 7.6 0.6 9.1 5.7 0.4 0 0.4 0.4 229 3 231 305 60 0 60 0 -16.4 0 -16.4 -16.6 02/15/2005 09:40:00 8.1 0.5 9.1 6.8 7.3 0.6 8.8 5.3 0.4 0 0.4 0.4 229 3 238 305 60 0 60 0 -16.4 0 -16.2 -16.6 02/15/2005 09:50:00 8.1 0.5 9.1 6.5 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 229 4 231 305 60 0 60 0 -16.4 0 -16.2 -16.6 02/15/2005 10:00:00 8.2 0.5 9.5 6.8 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 229 4 230 305 60 0 60 0 -16.4 0 -16 -16.6 02/15/2005 10:10:00 7.9 0.5 9.1 6.5 7.2 0.6 8.4 5.3 0.4 0 0.4 0.4 227 4 224 305 59 0 59 0 -16.5 0 -16.4 -16.6 02/15/2005 10:20:00 8 0.5 9.1 6.8 7.2 0.7 8.8 5.3 0.4 0 0.4 0.4 227 3 227 305 59 0 59 0 -16.6 0 -16.4 -16.6 02/15/2005 10:30:00 7.5 0.6 8.8 5.3 6.7 0.7 8.4 4.6 0.4 0 0.4 0.4 226 4 221 305 59 0 59 0 -16.6 0 -16.6 -16.9 02/15/2005 10:40:00 7.8 0.5 8.8 6.1 7 0.6 8.4 5.3 0.4 0 0.4 0.4 224 3 228 305 59 0 59 0 -16.6 0 -16.4 -16.7 02/15/2005 10:50:00 7.6 0.5 8.8 6.1 6.8 0.5 8 5.3 0.4 0 0.4 0.4 223 4 223 305 59 0 59 0 -16.4 0 -16.4 -16.6 02/15/2005 11:00:00 7.6 0.4 8.8 6.5 6.9 0.5 8.4 5.3 0.4 0 0.4 0.4 226 3 228 305 60 0 60 0 -16.4 0 -16.2 -16.6 02/15/2005 11:10:00 8.1 0.5 9.1 6.8 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 229 3 228 305 60 0 60 0 -16.2 0.1 -16 -16.6 02/15/2005 11:20:00 7.8 0.5 8.8 5.7 7 0.6 8.4 5.3 0.4 0 0.4 0.4 230 3 232 305 61 0 61 0 -16.1 0 -15.8 -16.2 02/15/2005 11:30:00 7.5 0.4 8.4 6.1 6.9 0.5 8 5.3 0.4 0 0.4 0.4 230 3 228 305 62 0 62 0 -16 0 -15.8 -16.2 02/15/2005 11:40:00 7.3 0.5 8.4 5.7 6.5 0.6 8 4.9 0.4 0 0.4 0.4 226 4 224 305 63 1 63 0 -16.1 0 -15.8 -16.4 02/15/2005 11:50:00 7.3 0.6 8.8 5.3 6.6 0.8 8.4 4.9 0.4 0 0.4 0.4 226 4 227 305 67 1 65 0 -15.8 0 -15.6 -16 02/15/2005 12:00:00 7.9 0.6 9.5 5.7 7.1 0.8 8.8 5.3 0.4 0 0.4 0.4 227 4 234 305 71 1 72 0 -15.7 0.1 -15.2 -15.8 02/15/2005 12:10:00 8.5 0.6 9.9 6.5 7.8 0.7 9.5 5.7 0.4 0 0.4 0.4 228 3 228 305 74 1 74 0 -15.7 0.1 -15.2 -15.8 02/15/2005 12:20:00 8.2 0.6 9.5 5.7 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 227 4 231 305 75 0 75 0 -15.7 0.1 -15.4 -15.8 02/15/2005 12:30:00 8.9 0.6 10.3 7.2 8.3 0.7 9.9 6.1 0.4 0 0.4 0.4 230 4 231 305 75 0 75 0 -15.7 0.1 -15.2 -15.8 02/15/2005 12:40:00 9.3 0.6 10.7 7.6 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 231 4 234 305 72 1 71 0 -15.7 0 -15.4 -15.8 02/15/2005 12:50:00 9.4 0.6 10.7 7.6 8.6 0.8 10.3 6.1 0.4 0 0.4 0.4 230 4 231 305 69 0 69 0 -15.8 0 -15.4 -15.8 02/15/2005 13:00:00 9 0.6 10.3 6.8 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 227 4 223 305 68 0 68 0 -15.8 0 -15.4 -16 02/15/2005 13:10:00 8.8 0.6 10.3 7.2 8.1 0.8 10.3 5.7 0.4 0 0.4 0.4 229 3 228 305 68 0 68 0 -15.5 0.1 -15.2 -15.8 02/15/2005 13:20:00 9.3 0.6 10.7 7.6 8.5 0.7 9.9 6.5 0.4 0 0.4 0.4 233 4 234 305 69 0 68 0 -15.2 0.1 -15 -15.4 02/15/2005 13:30:00 8.7 0.9 10.3 6.1 7.7 1 9.9 5.3 0.4 0 0.4 0.4 239 5 241 305 71 0 71 0 -15.1 0 -14.8 -15.2 02/15/2005 13:40:00 8.7 0.7 10.7 6.8 7.7 0.8 9.9 6.1 0.4 0 0.4 0.4 241 5 240 305 71 0 71 0 -15.1 0 -15 -15.2 02/15/2005 13:50:00 9.2 0.9 11.5 6.5 8.1 1 10.3 5.3 0.4 0 0.4 0.4 242 5 239 305 73 0 72 0 -14.9 0 -14.6 -15 02/15/2005 14:00:00 9.4 0.9 11.1 6.8 8.2 1 10.3 5.7 0.4 0 0.4 0.4 242 4 239 305 75 1 76 0 -14.7 0 -14.4 -14.8 02/15/2005 14:10:00 10 0.7 11.5 7.6 8.8 0.8 10.7 6.5 0.4 0 0.4 0.4 243 4 245 305 77 0 77 0 -14.8 0 -14.6 -15 02/15/2005 14:20:00 9.6 0.9 11.5 6.1 8.4 1 10.7 5.3 0.4 0 0.4 0.4 243 5 239 305 78 0 78 0 -14.9 0 -14.6 -15 02/15/2005 14:30:00 9.3 1.1 11.5 6.1 8.1 1.1 11.1 5.3 0.4 0 0.4 0.4 243 5 243 305 78 0 77 0 -15.1 0 -14.8 -15.2 02/15/2005 14:40:00 9.4 0.9 11.5 6.8 8.2 1 9.9 4.6 0.4 0 0.4 0.4 246 6 249 305 77 0 77 0 -14.8 0 -14.6 -15 02/15/2005 14:50:00 9.8 1.1 12.2 7.6 8.3 1.1 11.1 5.7 0.4 0 0.4 0.4 250 6 254 305 77 0 78 0 -14.7 0.1 -14.4 -15 02/15/2005 15:00:00 10.4 1 12.2 7.2 9 1.1 11.5 4.9 0.4 0 0.4 0.4 249 5 251 305 78 0 78 0 -14.8 0.1 -14.6 -15 02/15/2005 15:10:00 9.7 1.2 12.2 6.5 8.2 1.3 11.1 4.9 0.4 0 0.4 0.4 251 6 265 305 77 0 78 0 -14.7 0 -14.3 -15 02/15/2005 15:20:00 10 1.1 11.8 6.5 8.4 1.2 10.7 5.3 0.4 0 0.4 0.4 251 5 251 305 78 0 78 0 -14.7 0 -14.4 -14.8 02/15/2005 15:30:00 9.4 1.2 11.8 5.7 7.9 1.5 10.3 4.6 0.4 0 0.4 0.4 251 6 257 305 78 0 78 0 -14.7 0 -14.3 -14.8 02/15/2005 15:40:00 9.2 1 11.5 5.7 7.6 1.2 9.9 3.8 0.4 0 0.4 0.4 253 5 255 305 78 0 78 0 -14.7 0 -14.3 -14.6 02/15/2005 15:50:00 8.9 1 11.1 6.1 7.7 1.1 9.9 4.6 0.4 0 0.4 0.4 248 5 247 305 79 0 79 0 -14.7 0 -14.3 -14.8 02/15/2005 16:00:00 9.6 1.2 11.8 6.1 8.3 1.1 10.3 4.9 0.4 0 0.4 0.4 246 4 246 305 79 0 79 0 -14.7 0 -14.4 -14.8 02/15/2005 16:10:00 9.6 0.9 11.5 6.5 8.2 1 10.3 4.9 0.4 0 0.4 0.4 250 5 245 305 79 0 79 0 -14.7 0 -14.3 -14.8 02/15/2005 16:20:00 8.7 1.1 11.5 5.7 7.5 1.1 9.9 4.6 0.4 0 0.4 0.4 248 5 248 305 80 0 80 0 -14.7 0 -14.3 -14.8 02/15/2005 16:30:00 8.4 1 10.3 5.3 7.1 1 9.1 4.2 0.4 0 0.4 0.4 250 6 252 305 79 0 80 0 -14.8 0 -14.4 -15 02/15/2005 16:40:00 8.7 1 10.7 5.7 7.5 1.1 9.5 4.6 0.4 0 0.4 0.4 249 5 251 305 78 0 78 0 -14.8 0 -14.4 -15 02/15/2005 16:50:00 8.7 0.9 11.5 6.1 7.3 1 9.9 4.6 0.4 0 0.4 0.4 251 7 250 305 77 0 77 0 -14.8 0 -14.4 -15 02/15/2005 17:00:00 7.7 1.1 9.9 4.6 6.4 1.1 9.1 3.4 0.4 0 0.4 0.4 253 7 251 305 76 0 76 0 -14.8 0 -14.6 -15 02/15/2005 17:10:00 8.4 0.8 9.9 6.1 7.3 0.9 8.8 4.6 0.4 0 0.4 0.4 250 5 249 305 76 0 76 0 -14.8 0 -14.4 -15 02/15/2005 17:20:00 7.4 1 9.9 4.9 5.7 0.8 8 3.8 0.4 0 0.4 0.4 259 7 261 305 75 0 75 0 -15 0.1 -14.6 -15.2 02/15/2005 17:30:00 6.9 0.9 8.4 3.8 5.7 0.8 7.6 3.4 0.4 0 0.4 0.4 254 6 261 305 74 0 74 0 -15.1 0 -14.6 -15 02/15/2005 17:40:00 6.5 0.9 8.4 3.8 5.1 1.1 7.6 2.6 0.4 0 0.4 0.4 258 6 254 305 73 0 74 0 -15.1 0.1 -14.8 -15.2 02/15/2005 17:50:00 7.2 0.5 8.4 5.7 6 0.7 7.6 3.8 0.4 0 0.4 0.4 254 4 258 305 73 0 73 0 -15.2 0 -15 -15.4 02/15/2005 18:00:00 6.8 0.7 8.8 5.3 5.5 0.8 7.2 3.4 0.4 0 0.4 0.4 254 5 252 305 73 0 73 0 -15.3 0 -15 -15.4 02/15/2005 18:10:00 7 0.8 8.8 4.6 5 0.7 6.8 2.6 0.4 0 0.4 0.4 263 6 265 305 72 0 72 0 -15.3 0 -15 -15.4 02/15/2005 18:20:00 7.2 0.7 8.8 4.9 5.1 0.7 7.6 3.8 0.4 0 0.4 0.4 263 5 263 305 71 0 72 0 -15.5 0 -15.2 -15.6 02/15/2005 18:30:00 6.4 0.6 8 4.9 4.7 0.8 6.8 2.6 0.4 0 0.4 0.4 261 5 257 305 70 0 71 0 -15.6 0 -15.4 -15.6 02/15/2005 18:40:00 6.5 0.6 8 4.6 5 0.7 6.8 2.6 0.4 0 0.4 0.4 260 5 254 305 69 0 68 0 -15.7 0 -15.6 -15.8 02/15/2005 18:50:00 7 0.6 8.4 5.3 5.3 0.7 6.8 3.4 0.4 0 0.4 0.4 260 4 261 305 67 0 67 0 -15.9 0 -15.8 -16 02/15/2005 19:00:00 6.6 0.5 8 5.3 5 0.7 7.2 3 0.4 0 0.4 0.4 260 4 261 305 65 0 66 0 -16 0 -15.8 -16.2 02/15/2005 19:10:00 6.9 0.5 8 5.7 5.5 0.7 7.6 3.8 0.4 0 0.4 0.4 258 4 261 305 64 0 65 0 -16 0 -15.8 -16.2 02/15/2005 19:20:00 6.8 0.5 8 5.3 5.2 0.6 6.8 3.4 0.4 0 0.4 0.4 259 5 256 305 63 0 63 0 -16 0 -16 -16.2 02/15/2005 19:30:00 6.3 0.5 7.6 4.9 4.8 0.7 6.5 3 0.4 0 0.4 0.4 259 4 264 305 62 0 63 0 -16 0 -16 -16.2 02/15/2005 19:40:00 6 0.6 7.2 4.6 4.6 0.7 6.1 2.6 0.4 0 0.4 0.4 258 4 261 305 61 0 61 0 -16.2 0 -16 -16.4 02/15/2005 19:50:00 5.9 0.5 6.8 3.8 4.8 0.5 6.1 3.8 0.4 0 0.4 0.4 256 4 247 305 60 0 61 0 -16.3 0 -16 -16.4 02/15/2005 20:00:00 5.7 0.5 7.2 4.6 4.5 0.6 6.1 2.6 0.4 0 0.4 0.4 258 5 258 305 60 0 60 0 -16.3 0 -16 -16.4 02/15/2005 20:10:00 5.7 0.7 7.2 3.8 4.5 0.9 6.5 2.3 0.4 0 0.4 0.4 257 5 252 305 59 0 59 0 -16.3 0 -16 -16.4 02/15/2005 20:20:00 5.7 0.7 7.6 4.2 4.1 0.6 5.7 2.3 0.4 0 0.4 0.4 262 5 268 305 58 0 59 0 -16.4 0 -16.2 -16.6 02/15/2005 20:30:00 5.7 0.6 7.2 4.2 4.1 0.7 5.7 2.6 0.4 0 0.4 0.4 261 5 269 305 58 0 58 0 -16.3 0 -16 -16.4 02/15/2005 20:40:00 6.2 0.5 7.6 4.6 4.8 0.7 6.5 2.6 0.4 0 0.4 0.4 258 5 265 305 58 0 58 0 -16.3 0 -16 -16.4 02/15/2005 20:50:00 6 0.6 7.2 4.2 4.7 0.7 6.1 2.6 0.4 0 0.4 0.4 258 5 262 305 57 0 58 0 -16.4 0 -16.2 -16.6 02/15/2005 21:00:00 5.4 0.8 7.2 3.4 4.1 0.8 6.5 2.3 0.4 0 0.4 0.4 260 5 255 305 57 0 57 0 -16.4 0 -16.2 -16.6 02/15/2005 21:10:00 5.2 0.6 6.5 3.8 3.9 0.6 5.3 2.3 0.4 0 0.4 0.4 259 6 264 305 57 0 57 0 -16.5 0 -16.4 -16.6 02/15/2005 21:20:00 5.4 0.6 6.8 3.4 4.2 0.7 5.7 2.6 0.4 0 0.4 0.4 257 5 258 305 56 0 57 0 -16.6 0 -16.4 -16.7 02/15/2005 21:30:00 5.4 0.6 6.8 3.4 4.3 0.6 6.5 2.6 0.4 0 0.4 0.4 255 5 256 305 56 0 56 0 -16.6 0 -16.4 -16.9 02/15/2005 21:40:00 5.7 0.4 6.8 4.6 4.2 0.6 6.1 3 0.4 0 0.4 0.4 261 4 254 305 56 0 56 0 -16.6 0 -16.4 -16.7 02/15/2005 21:50:00 4.5 0.8 6.1 3 3.1 0.6 4.6 1.9 0.4 0 0.4 0.4 266 6 258 305 56 0 56 0 -16.7 0.1 -16.4 -16.9 02/15/2005 22:00:00 5.2 0.5 6.5 3.8 3.4 0.5 4.9 2.3 0.4 0 0.4 0.4 266 4 268 305 55 0 55 0 -16.9 0 -16.7 -16.9 02/15/2005 22:10:00 4.5 0.3 5.3 3.8 2.9 0.4 4.2 1.9 0.4 0 0.4 0.4 266 3 266 305 54 0 55 0 -16.9 0 -16.9 -16.9 02/15/2005 22:20:00 4.6 0.3 5.3 3.4 3.1 0.4 3.8 2.3 0.4 0 0.4 0.4 268 3 269 305 54 0 54 0 -17 0 -16.9 -17.1 02/15/2005 22:30:00 4.4 0.4 5.3 3 2.9 0.3 3.8 1.9 0.4 0 0.4 0.4 269 3 266 305 53 0 53 0 -17.1 0 -16.9 -17.3 02/15/2005 22:40:00 4.2 0.4 4.9 3 2.9 0.4 3.8 1.9 0.4 0 0.4 0.4 271 4 275 305 53 0 53 0 -17.1 0 -16.9 -17.3 02/15/2005 22:50:00 3.8 0.4 4.6 2.6 2.5 0.3 3.4 1.5 0.4 0 0.4 0.4 268 4 269 305 52 0 52 0 -17.1 0 -16.9 -17.3 02/15/2005 23:00:00 4 0.4 4.9 3 2.8 0.4 3.8 1.9 0.4 0 0.4 0.4 272 3 276 305 52 0 52 0 -17.2 0 -16.9 -17.3 02/15/2005 23:10:00 3.7 0.6 4.9 2.3 2.8 0.7 4.2 0.7 0.4 0 0.4 0.4 281 9 271 305 51 0 51 0 -17.3 0 -16.9 -17.5 02/15/2005 23:20:00 3.6 0.4 4.6 2.3 3.4 0.3 4.2 2.3 0.4 0 0.4 0.4 303 8 290 305 52 1 51 0 -17.5 0 -17.5 -17.9 02/15/2005 23:30:00 3.2 0.5 4.6 2.3 3.2 0.4 4.2 2.3 0.4 0 0.4 0.4 311 8 308 305 52 0 51 0 -17.5 0.1 -17.3 -18.1 02/15/2005 23:40:00 4 0.3 4.6 3 3.8 0.3 4.6 3 0.4 0 0.4 0.4 312 10 312 305 50 0 50 0 -17.6 0.1 -17.5 -18.1 02/15/2005 23:50:00 4.1 0.3 4.6 3.4 4 0.3 4.6 3 0.4 0 0.4 0.4 312 8 316 305 49 0 50 0 -17.7 0.1 -16.9 -17.9 02/16/2005 00:00:00 4.1 0.3 4.6 3.4 4 0.3 4.6 3.4 0.4 0 0.4 0.4 311 7 313 305 49 0 46 0 -17.7 0 -17.3 -17.9 02/16/2005 00:10:00 3.7 0.3 4.2 3 3.6 0.3 4.2 2.6 0.4 0 0.4 0.4 312 6 305 305 48 0 49 0 -17.7 0 -17.3 -17.9 02/16/2005 00:20:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.6 0.4 0 0.4 0.4 310 8 308 305 48 0 48 0 -18.1 0.2 -17.3 -18.4 02/16/2005 00:30:00 3.3 0.3 3.8 2.6 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 313 5 312 305 47 0 47 0 -18.4 0.1 -18.1 -18.4 02/16/2005 00:40:00 3.3 0.2 3.8 2.6 3.5 0.2 4.2 3 0.4 0 0.4 0.4 319 5 316 305 45 0 46 0 -18.5 0 -18.1 -18.8 02/16/2005 00:50:00 3 0.2 3.4 2.3 3.2 0.3 3.8 2.6 0.4 0 0.4 0.4 328 5 329 305 44 0 44 0 -17.9 0.2 -17.5 -18.4 02/16/2005 01:00:00 2.9 0.3 3.8 1.9 3 0.3 3.8 2.3 0.4 0 0.4 0.4 333 5 337 305 44 0 43 0 -17.9 0.1 -17.5 -18.1 02/16/2005 01:10:00 2.4 0.3 3 1.5 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 348 4 344 305 44 0 43 0 -17.5 0 -17.1 -17.7 02/16/2005 01:20:00 5.9 1.3 7.6 2.3 5.9 1.3 7.6 2.6 0.4 0 0.4 0.4 40 18 52 305 44 0 45 0 -18.3 0.4 -17.1 -18.8 02/16/2005 01:30:00 7.3 0.4 8.4 6.1 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 51 5 52 305 45 0 45 0 -18.7 0 -18.1 -18.8 02/16/2005 01:40:00 7.5 0.5 8.8 6.1 7.7 0.5 8.8 6.5 0.4 0 0.4 0.4 54 4 58 305 45 0 45 0 -18.9 0.1 -18.4 -19 02/16/2005 01:50:00 7.3 0.4 8.4 5.7 7.4 0.5 8.8 5.3 0.4 0 0.4 0.4 52 3 56 305 45 0 45 0 -19.1 0 -18.4 -19.2 02/16/2005 02:00:00 7.3 0.7 8.8 5.7 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 51 4 54 305 45 0 45 0 -19.1 0 -18.6 -19.2 02/16/2005 02:10:00 7.7 0.5 9.1 6.5 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 51 4 50 305 44 0 44 0 -19.2 0 -18.8 -19.5 02/16/2005 02:20:00 8.1 0.5 9.1 6.5 8.2 0.6 9.1 6.5 0.4 0 0.4 0.4 53 5 56 305 44 0 44 0 -19.3 0.1 -18.8 -19.5 02/16/2005 02:30:00 8.2 0.6 9.1 6.1 8.3 0.7 9.5 6.1 0.4 0 0.4 0.4 53 5 48 305 44 0 44 0 -19.5 0 -19 -19.5 02/16/2005 02:40:00 8.2 0.7 9.5 6.5 8.2 0.8 9.9 6.5 0.4 0 0.4 0.4 56 4 57 305 43 0 43 0 -19.6 0 -19.2 -19.7 02/16/2005 02:50:00 8.4 0.5 9.5 6.5 8.5 0.6 9.5 6.5 0.4 0 0.4 0.4 54 3 57 305 43 0 43 0 -19.6 0 -19.2 -19.7 02/16/2005 03:00:00 8 0.6 9.5 6.1 8 0.6 9.1 6.1 0.4 0 0.4 0.4 53 5 59 305 43 0 42 0 -19.7 0 -19.2 -19.9 02/16/2005 03:10:00 8.8 0.7 10.3 6.8 8.8 0.8 10.3 6.8 0.4 0 0.4 0.4 41 5 39 305 42 0 42 0 -19.7 0 -19.5 -19.9 02/16/2005 03:20:00 9.4 0.5 10.7 7.6 9.5 0.6 11.1 7.2 0.4 0 0.4 0.4 43 4 46 305 42 0 42 0 -19.8 0 -19.5 -20.1 02/16/2005 03:30:00 9.1 0.5 10.3 7.6 9.1 0.6 10.3 7.6 0.4 0 0.4 0.4 41 3 36 305 41 0 41 0 -19.9 0 -19.7 -20.1 02/16/2005 03:40:00 9.1 0.5 10.3 7.6 9.2 0.6 10.3 7.2 0.4 0 0.4 0.4 46 4 47 305 41 0 41 0 -19.9 0 -19.5 -20.1 02/16/2005 03:50:00 8.9 0.6 10.3 7.2 8.9 0.7 10.3 6.8 0.4 0 0.4 0.4 50 4 50 305 41 0 41 0 -20 0 -19.9 -20.1 02/16/2005 04:00:00 8.8 0.6 10.3 7.2 8.8 0.7 10.7 6.8 0.4 0 0.4 0.4 51 4 50 305 41 0 41 0 -19.9 0 -19.5 -20.1 02/16/2005 04:10:00 8.7 0.5 9.9 7.2 8.7 0.6 9.9 6.5 0.4 0 0.4 0.4 45 4 40 305 41 0 41 0 -19.8 0 -19.3 -20.1 02/16/2005 04:20:00 8.8 0.5 9.9 6.8 8.9 0.6 10.3 6.8 0.4 0 0.4 0.4 46 4 45 305 41 0 41 0 -19.8 0 -19.2 -19.9 02/16/2005 04:30:00 9.2 0.6 10.7 7.6 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 49 4 52 305 41 0 41 0 -19.8 0 -19.5 -20.1 02/16/2005 04:40:00 9.3 0.7 11.1 7.6 9.2 0.8 11.1 7.2 0.4 0 0.4 0.4 45 5 42 305 41 0 41 0 -19.7 0 -19.3 -20.1 02/16/2005 04:50:00 9.2 0.8 11.5 7.2 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 45 5 46 305 41 0 41 0 -19.8 0 -19.3 -19.9 02/16/2005 05:00:00 10.1 0.6 12.2 8.8 10 0.7 11.8 8 0.4 0 0.4 0.4 42 3 42 305 41 0 41 0 -19.7 0 -19.3 -19.9 02/16/2005 05:10:00 9.2 0.7 10.7 6.8 9.1 0.7 10.7 6.8 0.4 0 0.4 0.4 46 3 46 305 41 0 41 0 -19.7 0 -19.5 -19.9 02/16/2005 05:20:00 8.9 0.8 10.7 6.5 9 0.9 10.7 6.1 0.4 0 0.4 0.4 44 5 39 305 41 0 41 0 -19.7 0 -19.5 -19.9 02/16/2005 05:30:00 9 0.7 10.3 6.8 9.1 0.7 10.3 6.5 0.4 0 0.4 0.4 40 4 32 305 41 0 41 0 -19.6 0 -19.5 -19.7 02/16/2005 05:40:00 9.5 0.6 10.7 7.6 9.5 0.7 10.7 7.6 0.4 0 0.4 0.4 43 3 43 305 41 0 41 0 -19.6 0 -19.5 -19.7 02/16/2005 05:50:00 9.3 0.7 11.1 7.2 9.2 0.8 11.1 7.2 0.4 0 0.4 0.4 41 4 34 305 42 0 42 0 -19.5 0 -19.3 -19.5 02/16/2005 06:00:00 9.7 0.7 11.5 8 9.7 0.8 11.1 7.6 0.4 0 0.4 0.4 41 4 42 305 42 0 41 0 -19.4 0 -19 -19.5 02/16/2005 06:10:00 9.8 0.7 11.1 7.6 9.7 0.8 11.1 7.6 0.4 0 0.4 0.4 42 3 42 305 42 0 42 0 -19.4 0 -19.3 -19.5 02/16/2005 06:20:00 9.6 0.6 11.1 7.6 9.6 0.7 11.1 7.2 0.4 0 0.4 0.4 43 3 40 305 42 0 42 0 -19.4 0 -19 -19.5 02/16/2005 06:30:00 9.7 0.6 11.1 8 9.7 0.7 11.1 7.6 0.4 0 0.4 0.4 46 4 47 305 42 0 42 0 -19.3 0 -19.2 -19.5 02/16/2005 06:40:00 9.9 0.8 12.6 8.4 9.7 0.8 11.8 7.2 0.4 0 0.4 0.4 45 6 34 305 43 0 43 0 -19.2 0 -19 -19.3 02/16/2005 06:50:00 9.9 0.7 11.5 8 9.8 0.7 11.5 8 0.4 0 0.4 0.4 41 5 43 305 43 0 43 0 -19.2 0 -19 -19.3 02/16/2005 07:00:00 11 0.9 13.3 8 10.9 0.9 13.3 7.6 0.4 0 0.4 0.4 38 5 41 305 43 0 43 0 -19.2 0 -19 -19.5 02/16/2005 07:10:00 11 0.8 12.6 8.4 10.9 0.9 12.6 8.4 0.4 0 0.4 0.4 38 5 37 305 43 0 43 0 -19.3 0 -19.2 -19.5 02/16/2005 07:20:00 10.5 0.7 12.6 8.8 10.4 0.8 12.2 8 0.4 0 0.4 0.4 41 4 40 305 43 0 43 0 -19.4 0 -19.2 -19.5 02/16/2005 07:30:00 11 0.8 12.6 8.4 10.9 0.9 12.6 8.4 0.4 0 0.4 0.4 39 3 41 305 43 0 43 0 -19.4 0 -19.2 -19.5 02/16/2005 07:40:00 11.1 0.8 12.6 9.1 11.1 0.8 12.6 8.8 0.4 0 0.4 0.4 41 4 41 305 43 0 43 0 -19.4 0 -19.2 -19.5 02/16/2005 07:50:00 10.5 1 12.6 8.4 10.4 1.1 12.6 8.4 0.4 0 0.4 0.4 41 4 43 305 43 0 43 0 -19.4 0 -19.2 -19.5 02/16/2005 08:00:00 10 0.7 11.8 8 9.9 0.8 11.5 7.6 0.4 0 0.4 0.4 45 5 51 305 43 0 43 0 -19.5 0.1 -19 -19.5 02/16/2005 08:10:00 9.5 0.7 11.5 7.2 9.4 0.7 11.1 7.6 0.4 0 0.4 0.4 45 4 41 305 43 0 42 0 -19.6 0 -19 -19.7 02/16/2005 08:20:00 9.4 0.6 10.7 7.6 9.3 0.7 10.7 8 0.4 0 0.4 0.4 40 5 52 305 42 0 42 0 -19.4 0 -19 -19.5 02/16/2005 08:30:00 9.9 0.9 11.8 8 9.8 0.9 12.2 7.2 0.4 0 0.4 0.4 33 5 28 305 43 0 43 0 -19.2 0 -18.4 -19.3 02/16/2005 08:40:00 9.9 1 11.8 7.6 9.8 1 12.2 7.2 0.4 0 0.4 0.4 24 6 22 305 43 0 43 0 -19 0 -18.4 -19.2 02/16/2005 08:50:00 10.6 0.8 13 8.8 10.6 0.8 13 8.8 0.4 0 0.4 0.4 20 5 10 305 44 0 44 0 -18.9 0 -18.4 -19 02/16/2005 09:00:00 10.4 0.7 11.8 8.4 10.5 0.7 12.2 8.8 0.4 0 0.4 0.4 13 4 16 305 44 0 44 0 -19.1 0 -18.8 -19.2 02/16/2005 09:10:00 10.2 0.7 11.8 8 10.2 0.8 11.8 8 0.4 0 0.4 0.4 20 5 23 305 44 0 44 0 -19.2 0 -19 -19.5 02/16/2005 09:20:00 10.1 0.9 12.2 6.8 10 1 12.2 6.8 0.4 0 0.4 0.4 32 8 34 305 44 0 43 0 -19.4 0.1 -19 -19.5 02/16/2005 09:30:00 10.5 0.7 12.2 8.4 10.4 0.8 12.2 8.4 0.4 0 0.4 0.4 31 4 39 305 43 0 43 0 -19.7 0 -19.5 -19.9 02/16/2005 09:40:00 10.1 0.7 11.5 7.6 10 0.8 11.5 7.6 0.4 0 0.4 0.4 29 4 34 305 42 0 43 0 -19.8 0 -19.5 -20.1 02/16/2005 09:50:00 10.6 0.6 11.8 8.4 10.5 0.6 12.2 8.4 0.4 0 0.4 0.4 23 6 29 305 42 0 42 0 -20 0 -19.7 -20.1 02/16/2005 10:00:00 10.5 0.8 12.2 8 10.5 0.8 12.2 8 0.4 0 0.4 0.4 21 5 23 305 41 0 41 0 -19.9 0 -19.3 -20.1 02/16/2005 10:10:00 10.6 0.7 12.6 8.8 10.6 0.8 13 8 0.4 0 0.4 0.4 27 5 29 305 41 0 41 0 -19.8 0 -19.3 -20.1 02/16/2005 10:20:00 10.5 1 12.2 7.6 10.4 1 13 8 0.4 0 0.4 0.4 29 5 27 305 42 0 42 0 -19.7 0 -19.2 -19.9 02/16/2005 10:30:00 11.4 0.8 13.3 9.1 11.3 0.8 13 8.8 0.4 0 0.4 0.4 29 4 30 305 42 0 42 0 -19.6 0 -19 -19.7 02/16/2005 10:40:00 11.5 0.8 13 9.5 11.4 0.8 13 9.1 0.4 0 0.4 0.4 32 5 31 305 42 0 42 0 -19.7 0 -19 -19.9 02/16/2005 10:50:00 11.6 0.8 13 9.1 11.5 0.9 13.3 8.8 0.4 0 0.4 0.4 37 4 32 305 42 0 42 0 -19.7 0 -19.5 -19.9 02/16/2005 11:00:00 11.1 0.6 12.6 9.1 10.9 0.8 13 8.8 0.4 0 0.4 0.4 35 4 31 305 42 0 42 0 -19.8 0 -19.2 -19.9 02/16/2005 11:10:00 12.1 0.9 13.3 9.5 12 1 13.7 9.5 0.4 0 0.4 0.4 32 3 35 305 42 0 42 0 -19.6 0 -19.5 -19.7 02/16/2005 11:20:00 12.3 0.7 14.1 10.7 12.1 0.8 14.1 9.9 0.4 0 0.4 0.4 30 3 29 305 42 0 42 0 -19.6 0 -19 -19.7 02/16/2005 11:30:00 12.8 0.6 14.5 11.1 12.6 0.7 14.5 10.7 0.4 0 0.4 0.4 30 3 36 305 43 0 43 0 -19.6 0 -19.5 -19.7 02/16/2005 11:40:00 13 0.6 14.1 11.1 12.9 0.6 14.1 11.1 0.4 0 0.4 0.4 30 3 35 305 43 0 43 0 -19.5 0 -19 -19.5 02/16/2005 11:50:00 13.6 0.7 14.9 11.5 13.5 0.8 15.3 11.1 0.4 0 0.4 0.4 30 3 30 305 45 0 46 0 -19.4 0 -19.2 -19.5 02/16/2005 12:00:00 14.4 0.7 16.4 12.2 14.2 0.8 16.4 11.1 0.4 0 0.4 0.4 34 3 40 305 46 0 47 0 -19.4 0 -19.2 -19.5 02/16/2005 12:10:00 13.9 0.7 15.6 11.8 13.7 0.9 15.6 11.1 0.4 0 0.4 0.4 35 4 35 305 48 0 47 0 -19.2 0 -19 -19.5 02/16/2005 12:20:00 13.5 1 16.1 11.1 13.2 1.1 16.1 10.7 0.4 0 0.4 0.4 33 4 27 305 50 0 50 0 -19.1 0 -18.6 -19.2 02/16/2005 12:30:00 13.8 1.2 16.8 10.7 13.5 1.2 16.1 10.7 0.4 0 0.4 0.4 35 4 34 305 51 0 52 0 -19 0 -18.8 -19 02/16/2005 12:40:00 14.6 1 16.8 11.5 14.4 1 16.4 11.5 0.4 0 0.4 0.4 34 3 33 305 52 0 52 0 -19 0 -18.8 -19 02/16/2005 12:50:00 14 0.8 15.6 11.8 13.9 0.9 15.3 11.5 0.4 0 0.4 0.4 38 4 35 305 53 0 53 0 -19 0 -18.8 -19 02/16/2005 13:00:00 13.9 0.8 15.3 11.8 13.8 0.9 15.3 11.8 0.4 0 0.4 0.4 40 3 36 305 54 0 54 0 -19 0 -18.8 -19.2 02/16/2005 13:10:00 13.6 0.9 15.6 11.1 13.3 1 15.6 10.7 0.4 0 0.4 0.4 42 4 48 305 54 0 55 0 -19.1 0 -19 -19.2 02/16/2005 13:20:00 13 1 14.9 10.7 13 1.1 15.3 9.9 0.4 0 0.4 0.4 40 4 39 305 55 0 54 0 -19.1 0 -19 -19.2 02/16/2005 13:30:00 14 0.8 15.6 11.5 14 0.9 15.6 11.8 0.4 0 0.4 0.4 39 3 39 305 55 0 55 0 -19.2 0 -19 -19.5 02/16/2005 13:40:00 14.1 0.7 15.6 11.8 14 0.8 15.6 11.8 0.4 0 0.4 0.4 38 3 36 305 54 0 54 0 -19.1 0 -19 -19.2 02/16/2005 13:50:00 13.8 0.9 16.1 11.5 13.6 1.1 16.1 10.7 0.4 0 0.4 0.4 39 3 42 305 55 0 54 0 -19 0 -18.6 -19 02/16/2005 14:00:00 14.4 0.8 16.1 11.8 14.3 0.9 16.4 11.5 0.4 0 0.4 0.4 40 3 40 305 55 0 55 0 -18.9 0 -18.6 -19 02/16/2005 14:10:00 14.5 0.5 15.6 12.2 14.4 0.6 15.6 12.6 0.4 0 0.4 0.4 39 3 43 305 55 0 55 0 -19 0 -18.8 -19 02/16/2005 14:20:00 13.7 0.8 14.9 11.5 13.6 0.9 15.3 11.5 0.4 0 0.4 0.4 42 3 45 305 55 0 56 0 -18.9 0 -18.6 -19 02/16/2005 14:30:00 14 0.9 15.6 11.1 13.9 1 15.6 10.3 0.4 0 0.4 0.4 42 3 48 305 56 0 56 0 -18.9 0 -18.6 -19 02/16/2005 14:40:00 14.3 1 16.4 11.5 14.2 1 16.4 11.1 0.4 0 0.4 0.4 39 3 39 305 56 0 56 0 -18.9 0 -18.6 -19 02/16/2005 14:50:00 14.6 1 16.8 11.8 14.5 1.1 17.2 11.5 0.4 0 0.4 0.4 41 4 37 305 55 0 55 0 -19 0 -18.8 -19 02/16/2005 15:00:00 15 0.7 16.4 13 14.8 1 17.2 11.8 0.4 0 0.4 0.4 44 3 40 305 56 0 55 0 -19 0 -18.8 -19 02/16/2005 15:10:00 14.1 1 16.1 11.8 14 1.1 16.1 11.5 0.4 0 0.4 0.4 43 4 42 305 56 0 55 0 -18.9 0.1 -18.4 -19 02/16/2005 15:20:00 14.2 0.8 16.1 11.8 14 1 16.1 11.8 0.4 0 0.4 0.4 39 5 36 305 56 0 56 0 -18.7 0 -18.4 -19 02/16/2005 15:30:00 14.5 0.9 16.4 11.8 14.5 1 16.4 11.5 0.4 0 0.4 0.4 39 3 39 305 56 0 56 0 -18.7 0 -18.4 -19 02/16/2005 15:40:00 14.3 0.8 16.1 11.1 14.1 1 16.1 11.1 0.4 0 0.4 0.4 35 4 31 305 56 0 56 0 -18.7 0 -18.4 -19 02/16/2005 15:50:00 15.2 0.6 16.4 12.6 15 0.8 16.4 12.6 0.4 0 0.4 0.4 36 3 35 305 56 0 55 0 -19 0 -18.8 -19 02/16/2005 16:00:00 14.6 0.8 16.4 12.2 14.5 0.9 16.8 11.8 0.4 0 0.4 0.4 37 3 41 305 55 0 55 0 -19 0.1 -18.8 -19 02/16/2005 16:10:00 14.9 0.8 16.8 12.6 14.8 0.8 16.8 12.2 0.4 0 0.4 0.4 37 4 32 305 55 0 55 0 -19 0 -18.8 -19 02/16/2005 16:20:00 15 0.8 16.4 12.6 14.9 0.9 16.4 12.6 0.4 0 0.4 0.4 38 3 38 305 55 0 55 0 -19.1 0 -18.8 -19.2 02/16/2005 16:30:00 14.6 0.8 16.8 12.6 14.4 0.9 16.8 11.8 0.4 0 0.4 0.4 38 4 42 305 55 0 55 0 -19.1 0 -18.8 -19.2 02/16/2005 16:40:00 14.7 0.9 16.4 11.5 14.7 0.9 16.4 11.8 0.4 0 0.4 0.4 41 4 44 305 55 0 54 0 -19.1 0 -18.8 -19.2 02/16/2005 16:50:00 14.9 0.9 17.2 12.2 14.7 1 16.8 11.8 0.4 0 0.4 0.4 42 4 38 305 54 0 54 0 -19.1 0 -19 -19.2 02/16/2005 17:00:00 15.2 1.1 17.2 12.6 15.1 1.2 17.6 12.2 0.4 0 0.4 0.4 41 4 36 305 54 0 54 0 -19.1 0 -18.8 -19.2 02/16/2005 17:10:00 13.8 0.8 15.6 11.5 13.6 0.9 15.6 11.5 0.4 0 0.4 0.4 42 4 41 305 53 0 53 0 -19.1 0 -18.8 -19.2 02/16/2005 17:20:00 14.5 1.2 17.2 11.8 14.2 1.3 17.2 11.5 0.4 0 0.4 0.4 38 4 38 305 53 0 53 0 -19 0 -18.8 -19 02/16/2005 17:30:00 14.7 0.8 16.4 12.2 14.5 1 16.8 12.2 0.4 0 0.4 0.4 39 4 43 305 53 0 53 0 -19 0 -18.8 -19.2 02/16/2005 17:40:00 15.6 1.2 17.6 12.6 15.3 1.2 17.9 11.8 0.4 0 0.4 0.4 40 4 36 305 53 0 53 0 -19 0 -18.8 -19 02/16/2005 17:50:00 16 1 18.3 13.3 15.7 1.1 18.3 12.6 0.4 0 0.4 0.4 39 4 38 305 52 0 52 0 -19.1 0 -18.8 -19.2 02/16/2005 18:00:00 15.7 1 18.3 13.3 15.6 1.2 18.3 12.6 0.4 0 0.4 0.4 38 4 36 305 51 0 52 0 -19.1 0 -19 -19.3 02/16/2005 18:10:00 15.6 0.8 17.6 13 15.4 1 17.2 13 0.4 0 0.4 0.4 42 3 40 305 50 0 51 0 -19.2 0 -19 -19.5 02/16/2005 18:20:00 15.7 0.8 17.6 13.3 15.6 0.9 17.6 12.6 0.4 0 0.4 0.4 43 3 45 305 49 0 49 0 -19.4 0 -19 -19.5 02/16/2005 18:30:00 15.6 0.8 17.2 13.3 15.5 1 17.2 12.6 0.4 0 0.4 0.4 42 3 46 305 48 0 48 0 -19.4 0 -19.2 -19.5 02/16/2005 18:40:00 15.7 1.1 18.3 13 15.5 1.2 18.3 12.6 0.4 0 0.4 0.4 39 4 36 305 46 0 46 0 -19.5 0 -19.2 -19.5 02/16/2005 18:50:00 16.2 1.1 18.7 13.3 15.9 1.2 18.3 12.6 0.4 0 0.4 0.4 41 4 43 305 45 0 45 0 -19.6 0 -19.5 -19.9 02/16/2005 19:00:00 16.3 0.9 18.3 13.7 16.2 1 18.3 13.7 0.4 0 0.4 0.4 41 3 46 305 44 0 44 0 -19.7 0 -19.5 -19.9 02/16/2005 19:10:00 16.3 1 18.7 13.3 16.1 1.1 19.1 13 0.4 0 0.4 0.4 40 3 39 305 44 0 43 0 -19.7 0 -19.5 -19.9 02/16/2005 19:20:00 16 1 17.6 13.3 15.7 1.1 17.9 13 0.4 0 0.4 0.4 42 4 42 305 43 0 43 0 -19.7 0 -19.5 -19.7 02/16/2005 19:30:00 16.7 1 18.7 14.1 16.3 1.2 18.7 13 0.4 0 0.4 0.4 44 3 43 305 43 0 43 0 -19.7 0 -19.5 -19.9 02/16/2005 19:40:00 17.3 1 19.1 14.1 17 1 19.1 13.7 0.4 0 0.4 0.4 37 4 40 305 42 0 43 0 -19.8 0.1 -19.5 -20.1 02/16/2005 19:50:00 17.2 1 19.1 14.5 17 1 19.1 14.1 0.4 0 0.4 0.4 39 4 32 305 42 0 42 0 -20 0 -19.7 -20.1 02/16/2005 20:00:00 17.7 0.9 19.5 14.9 17.5 1 19.9 14.5 0.4 0 0.4 0.4 40 3 39 305 42 0 42 0 -20 0.1 -19.5 -20.1 02/16/2005 20:10:00 18 1 19.9 14.9 17.8 1.1 20.2 14.5 0.4 0 0.4 0.4 43 3 38 305 41 0 41 0 -20 0.1 -19.5 -20.1 02/16/2005 20:20:00 17.5 1.1 19.5 13.7 17.2 1.2 19.9 13.3 0.4 0 0.4 0.4 41 5 44 305 41 0 41 0 -20 0.1 -19.5 -20.1 02/16/2005 20:30:00 18.1 1.1 20.2 14.9 18 1.2 20.6 14.5 0.4 0 0.4 0.4 42 4 40 305 42 0 41 0 -19.9 0.1 -19.3 -20.1 02/16/2005 20:40:00 17.3 1.2 19.5 14.1 17.2 1.4 19.9 13 0.4 0 0.4 0.4 43 3 43 305 42 0 42 0 -19.7 0.1 -19.2 -19.9 02/16/2005 20:50:00 17.6 1 19.5 14.5 17.6 1.1 19.9 14.1 0.4 0 0.4 0.4 40 3 41 305 43 0 43 0 -19.6 0 -19 -19.9 02/16/2005 21:00:00 18.6 0.9 20.6 14.9 18.6 1 20.6 14.9 0.4 0 0.4 0.4 41 3 41 305 43 0 42 0 -19.8 0.1 -19.5 -20.1 02/16/2005 21:10:00 19.2 0.9 21 15.6 19.1 1 21 15.6 0.4 0 0.4 0.4 43 3 41 305 42 0 42 0 -20 0 -19.7 -20.1 02/16/2005 21:20:00 19.2 1.1 21.8 16.1 19.2 1.1 21.4 15.6 0.4 0 0.4 0.4 41 3 38 305 42 0 42 0 -19.8 0.1 -19.5 -20.1 02/16/2005 21:30:00 18.5 1.1 21.4 15.6 18.4 1.2 21 15.3 0.4 0 0.4 0.4 42 4 39 305 43 0 43 0 -19.6 0 -19.3 -19.9 02/16/2005 21:40:00 18.9 1 21.8 16.1 18.9 1.1 21.4 16.1 0.4 0 0.4 0.4 45 3 46 305 43 0 43 0 -20 0.1 -19.5 -20.1 02/16/2005 21:50:00 18.6 0.8 20.6 16.8 18.5 0.9 20.2 15.6 0.4 0 0.4 0.4 44 3 46 305 42 0 42 0 -20.1 0 -19.9 -20.1 02/16/2005 22:00:00 17.7 0.9 19.5 14.5 17.6 1.1 19.9 14.5 0.4 0 0.4 0.4 41 3 38 305 41 0 41 0 -20.1 0.1 -19.5 -20.1 02/16/2005 22:10:00 16.8 1 18.7 13.7 16.6 1.1 18.7 13.7 0.4 0 0.4 0.4 37 5 36 305 41 0 42 0 -20 0.1 -19.7 -20.1 02/16/2005 22:20:00 17.9 0.8 19.5 15.6 17.8 0.9 19.5 15.3 0.4 0 0.4 0.4 34 3 36 305 41 0 41 0 -20.2 0 -19.9 -20.2 02/16/2005 22:30:00 17.7 0.7 19.5 15.6 17.5 0.7 19.1 15.3 0.4 0 0.4 0.4 37 3 38 305 41 0 41 0 -20.1 0 -19.9 -20.1 02/16/2005 22:40:00 17.7 1.1 19.9 14.9 17.6 1.2 19.9 14.5 0.4 0 0.4 0.4 41 4 41 305 41 0 41 0 -20 0.1 -19.7 -20.1 02/16/2005 22:50:00 18.4 0.9 20.6 15.6 18.3 1 20.2 14.5 0.4 0 0.4 0.4 41 5 43 305 42 0 42 0 -20.1 0 -19.9 -20.1 02/16/2005 23:00:00 18.1 0.9 19.5 14.9 17.8 1 19.9 14.5 0.4 0 0.4 0.4 38 4 33 305 41 0 41 0 -20.1 0 -19.9 -20.1 02/16/2005 23:10:00 17.8 1 19.9 14.9 17.6 1.1 19.9 14.9 0.4 0 0.4 0.4 37 4 38 305 41 0 41 0 -20.1 0 -19.9 -20.1 02/16/2005 23:20:00 17.8 1.1 20.2 14.5 17.7 1.2 19.9 14.1 0.4 0 0.4 0.4 38 4 42 305 42 0 41 0 -19.9 0.1 -19.5 -20.1 02/16/2005 23:30:00 17.2 1.2 19.5 13.7 17 1.2 19.5 14.1 0.4 0 0.4 0.4 37 5 35 305 42 0 42 0 -19.7 0 -19.5 -19.9 02/16/2005 23:40:00 17.4 1.1 19.9 14.1 17.3 1.2 19.9 14.1 0.4 0 0.4 0.4 37 5 32 305 43 0 42 0 -19.7 0 -19.3 -19.9 02/16/2005 23:50:00 17.2 1.3 20.2 13.3 17 1.2 19.5 13.3 0.4 0 0.4 0.4 33 4 30 305 43 0 43 0 -19.7 0.1 -19.3 -20.1 02/17/2005 00:00:00 17.6 1.1 19.9 14.1 17.4 1.2 19.9 14.1 0.4 0 0.4 0.4 34 5 46 305 42 0 42 0 -19.9 0 -19.5 -20.1 02/17/2005 00:10:00 16.2 1.5 19.5 12.6 16 1.6 19.5 12.2 0.4 0 0.4 0.4 34 5 35 305 42 0 42 0 -19.7 0 -19.5 -20.1 02/17/2005 00:20:00 15.2 1 17.6 12.2 15 1.2 17.9 11.5 0.4 0 0.4 0.4 29 4 22 305 42 0 42 0 -19.8 0.1 -19.5 -20.1 02/17/2005 00:30:00 15.8 1 17.9 13 15.6 1 17.6 11.8 0.4 0 0.4 0.4 30 4 33 305 42 0 42 0 -19.8 0 -19.5 -20.1 02/17/2005 00:40:00 16.7 0.9 19.1 13.7 16.5 1 18.3 13.7 0.4 0 0.4 0.4 33 5 29 305 42 0 42 0 -19.9 0 -19.7 -20.1 02/17/2005 00:50:00 17.3 1.2 19.9 13.3 17 1.2 19.5 13 0.4 0 0.4 0.4 36 4 41 305 42 0 42 0 -20.1 0 -19.9 -20.1 02/17/2005 01:00:00 15.3 1.3 17.9 12.2 15.1 1.3 17.9 11.8 0.4 0 0.4 0.4 31 6 32 305 41 0 41 0 -20 0.1 -19.7 -20.1 02/17/2005 01:10:00 16.5 1.1 18.7 13.7 16.3 1.2 18.7 13.3 0.4 0 0.4 0.4 34 3 36 305 41 0 41 0 -20.1 0 -19.9 -20.2 02/17/2005 01:20:00 16 1.2 18.3 12.2 15.9 1.3 18.3 12.6 0.4 0 0.4 0.4 32 5 23 305 41 0 41 0 -20.1 0.1 -19.9 -20.1 02/17/2005 01:30:00 17.6 1 19.5 14.5 17.4 1.1 20.2 14.1 0.4 0 0.4 0.4 37 4 39 305 41 0 41 0 -20.2 0 -20.1 -20.2 02/17/2005 01:40:00 17 1.1 19.1 14.1 16.7 1.2 19.5 13.7 0.4 0 0.4 0.4 31 5 39 305 41 0 41 0 -20.2 0 -19.9 -20.2 02/17/2005 01:50:00 18 0.9 20.2 15.6 17.7 1.2 20.2 14.9 0.4 0 0.4 0.4 34 5 29 305 41 0 41 0 -20.2 0 -20.1 -20.2 02/17/2005 02:00:00 16.6 1.5 19.5 13.3 16.4 1.5 19.5 12.6 0.4 0 0.4 0.4 35 5 40 305 41 0 41 0 -20 0.1 -19.3 -20.1 02/17/2005 02:10:00 17.8 1.3 20.2 14.1 17.4 1.3 19.9 14.1 0.4 0 0.4 0.4 34 5 37 305 41 0 41 0 -20.1 0 -19.9 -20.2 02/17/2005 02:20:00 18 1.2 20.2 13.7 17.8 1.3 20.2 13.7 0.4 0 0.4 0.4 34 4 39 305 41 0 41 0 -20.2 0 -20.1 -20.2 02/17/2005 02:30:00 16.9 1.3 20.2 14.1 16.6 1.4 20.2 13 0.4 0 0.4 0.4 35 5 32 305 41 0 41 0 -20.1 0 -19.9 -20.2 02/17/2005 02:40:00 16.5 1.2 19.5 13.3 16.2 1.2 18.7 13 0.4 0 0.4 0.4 33 6 42 305 41 0 41 0 -20.1 0 -19.7 -20.1 02/17/2005 02:50:00 17.9 1.2 20.6 14.1 17.6 1.3 20.2 13.7 0.4 0 0.4 0.4 33 5 34 305 41 0 41 0 -20.2 0 -20.1 -20.2 02/17/2005 03:00:00 17.8 1.5 21.4 13.7 17.5 1.5 21.4 13.7 0.4 0 0.4 0.4 30 6 40 305 40 0 40 0 -20.2 0 -20.1 -20.4 02/17/2005 03:10:00 17.9 1.2 20.6 13.7 17.6 1.3 20.6 13.7 0.4 0 0.4 0.4 39 4 35 305 41 0 40 0 -20.1 0.1 -19.9 -20.1 02/17/2005 03:20:00 17.4 1.7 21 13 17 1.7 21 12.6 0.4 0 0.4 0.4 36 5 40 305 41 0 41 0 -19.9 0.1 -19.5 -20.1 02/17/2005 03:30:00 18.1 1.1 20.6 14.1 17.9 1.1 20.6 14.1 0.4 0 0.4 0.4 36 5 42 305 41 0 41 0 -20 0 -19.9 -20.1 02/17/2005 03:40:00 18.5 1.3 21 14.5 18.1 1.5 21 14.5 0.4 0 0.4 0.4 33 4 30 305 41 0 41 0 -20.2 0 -19.9 -20.2 02/17/2005 03:50:00 19.2 1.2 22.6 14.9 18.8 1.4 22.1 13.3 0.4 0 0.4 0.4 37 6 34 305 40 0 41 0 -20.2 0.1 -20.1 -20.4 02/17/2005 04:00:00 18.9 1.3 22.1 14.5 18.6 1.4 22.1 14.5 0.4 0 0.4 0.4 40 4 39 305 40 0 40 0 -20.2 0 -20.1 -20.2 02/17/2005 04:10:00 17.8 1.3 20.6 14.9 17.6 1.3 21 14.5 0.4 0 0.4 0.4 42 4 39 305 41 0 40 0 -20 0.1 -19.7 -20.1 02/17/2005 04:20:00 18.5 1.4 21.4 14.1 18.2 1.4 21.4 13.7 0.4 0 0.4 0.4 37 5 39 305 41 0 41 0 -19.8 0.1 -19.5 -20.1 02/17/2005 04:30:00 18.9 1.3 21.8 15.3 18.7 1.5 21.4 14.5 0.4 0 0.4 0.4 37 4 45 305 41 0 41 0 -20.1 0 -19.5 -20.1 02/17/2005 04:40:00 20.3 1.2 22.6 17.2 20 1.2 22.6 16.4 0.4 0 0.4 0.4 36 3 35 305 41 0 40 0 -20.2 0 -19.9 -20.2 02/17/2005 04:50:00 19.9 1.1 21.8 16.8 19.5 1.1 21.8 16.1 0.4 0 0.4 0.4 37 4 36 305 40 0 40 0 -20.2 0 -20.1 -20.2 02/17/2005 05:00:00 19.8 1.2 22.1 15.6 19.5 1.3 22.1 14.9 0.4 0 0.4 0.4 42 4 44 305 40 0 40 0 -20.2 0 -19.9 -20.4 02/17/2005 05:10:00 18.5 1.1 21 15.6 18.2 1.2 21 15.3 0.4 0 0.4 0.4 42 4 41 305 40 0 40 0 -20.2 0 -20.1 -20.4 02/17/2005 05:20:00 20 1.3 22.6 15.6 19.7 1.3 22.6 14.9 0.4 0 0.4 0.4 42 4 42 305 40 0 40 0 -20.4 0.1 -20.1 -20.6 02/17/2005 05:30:00 19.7 1.2 22.6 16.1 19.4 1.5 22.9 14.1 0.4 0 0.4 0.4 40 4 40 305 39 0 39 0 -20.4 0.1 -20.1 -20.6 02/17/2005 05:40:00 20 1.3 22.6 16.8 19.8 1.4 22.9 16.4 0.4 0 0.4 0.4 41 4 46 305 39 0 39 0 -20.4 0 -20.1 -20.6 02/17/2005 05:50:00 19.3 1.5 22.1 14.5 18.9 1.6 22.1 13.7 0.4 0 0.4 0.4 41 4 38 305 39 0 39 0 -20.4 0.1 -20.1 -20.8 02/17/2005 06:00:00 19 1.3 21.8 16.1 18.6 1.3 21.4 15.6 0.4 0 0.4 0.4 40 5 33 305 39 0 39 0 -20.4 0 -20.2 -20.6 02/17/2005 06:10:00 19.2 1.3 21.8 14.9 18.8 1.5 21.4 14.9 0.4 0 0.4 0.4 36 4 35 305 39 0 39 0 -20.5 0 -20.2 -20.6 02/17/2005 06:20:00 19.1 1 21.4 15.6 18.7 1.2 21.4 15.6 0.4 0 0.4 0.4 35 4 37 305 39 0 39 0 -20.4 0 -20.2 -20.6 02/17/2005 06:30:00 19.2 1.2 22.1 15.6 18.7 1.2 22.1 14.9 0.4 0 0.4 0.4 37 4 36 305 39 0 39 0 -20.4 0 -20.1 -20.6 02/17/2005 06:40:00 18.4 1.5 22.9 14.1 18 1.6 22.1 14.1 0.4 0 0.4 0.4 37 5 41 305 39 0 39 0 -20.2 0 -20.1 -20.4 02/17/2005 06:50:00 17.4 1.3 20.6 14.1 17.1 1.4 20.2 13.3 0.4 0 0.4 0.4 36 4 31 305 39 0 39 0 -20.2 0 -20.1 -20.4 02/17/2005 07:00:00 18 1.7 22.6 13.7 17.8 1.7 22.9 13.7 0.4 0 0.4 0.4 37 5 36 305 39 0 39 0 -20.4 0 -20.1 -20.8 02/17/2005 07:10:00 17.3 1.7 21.8 13.3 16.8 1.7 21 12.6 0.4 0 0.4 0.4 34 5 30 305 39 0 39 0 -20.5 0 -20.2 -20.8 02/17/2005 07:20:00 18.3 1.2 20.2 14.1 17.8 1.3 20.6 13.3 0.4 0 0.4 0.4 33 5 30 305 39 0 39 0 -20.6 0 -20.2 -20.8 02/17/2005 07:30:00 17.3 1.4 21.4 12.6 16.9 1.4 21.4 13.3 0.4 0 0.4 0.4 34 5 39 305 39 0 39 0 -20.3 0 -20.1 -20.6 02/17/2005 07:40:00 18.2 1.4 21.4 14.5 17.9 1.5 21.4 14.1 0.4 0 0.4 0.4 35 5 36 305 39 0 39 0 -20.5 0.1 -20.1 -20.8 02/17/2005 07:50:00 17.7 1.3 21.4 14.1 17.4 1.4 20.6 14.1 0.4 0 0.4 0.4 35 4 31 305 39 0 39 0 -20.5 0 -20.1 -20.8 02/17/2005 08:00:00 18.5 1.2 21.4 15.3 18.2 1.3 21 14.5 0.4 0 0.4 0.4 36 5 39 305 39 0 39 0 -20.5 0.1 -20.1 -20.8 02/17/2005 08:10:00 18.6 1.3 21.4 14.1 18.2 1.4 21.4 13 0.4 0 0.4 0.4 38 4 39 305 39 0 39 0 -20.7 0 -20.4 -20.8 02/17/2005 08:20:00 18.4 1.1 21 15.6 18.1 1.2 21 14.5 0.4 0 0.4 0.4 37 4 40 305 38 0 38 0 -20.6 0 -20.4 -20.8 02/17/2005 08:30:00 18.6 1.5 22.1 14.1 18.3 1.4 21.8 14.1 0.4 0 0.4 0.4 37 4 33 305 38 0 38 0 -20.6 0.1 -20.2 -20.8 02/17/2005 08:40:00 19.5 1.5 22.6 15.6 19.2 1.5 22.9 14.5 0.4 0 0.4 0.4 37 4 33 305 38 0 39 0 -20.4 0.1 -20.1 -20.6 02/17/2005 08:50:00 18.9 1.3 22.6 15.3 18.8 1.3 21.8 15.3 0.4 0 0.4 0.4 39 4 34 305 39 0 39 0 -20.4 0 -20.1 -20.6 02/17/2005 09:00:00 18.9 1.3 21.4 14.5 18.6 1.4 21 14.1 0.4 0 0.4 0.4 36 3 39 305 38 0 39 0 -20.6 0.1 -20.2 -20.8 02/17/2005 09:10:00 17.7 1.2 20.2 13.3 17.3 1.3 19.9 13.3 0.4 0 0.4 0.4 32 4 32 305 38 0 38 0 -20.7 0 -20.6 -20.8 02/17/2005 09:20:00 18.1 1.5 21.4 13.7 17.8 1.6 21.4 13 0.4 0 0.4 0.4 36 4 50 305 38 0 38 0 -20.7 0 -20.6 -20.8 02/17/2005 09:30:00 18.3 1 20.6 15.3 17.8 1.1 20.2 14.5 0.4 0 0.4 0.4 34 4 33 305 38 0 38 0 -20.7 0 -20.4 -20.8 02/17/2005 09:40:00 18 1.2 20.6 14.5 17.6 1.4 20.6 13.3 0.4 0 0.4 0.4 38 5 43 305 38 0 38 0 -20.6 0.1 -20.2 -20.8 02/17/2005 09:50:00 17.7 1.4 20.6 14.1 17.4 1.4 20.2 13.3 0.4 0 0.4 0.4 38 4 35 305 38 0 38 0 -20.5 0 -20.2 -20.8 02/17/2005 10:00:00 19.4 1.7 22.6 14.5 19 1.8 22.1 14.5 0.4 0 0.4 0.4 37 4 35 305 38 0 38 0 -20.6 0.1 -20.2 -20.8 02/17/2005 10:10:00 18 1.2 20.6 14.9 17.7 1.3 21 14.1 0.4 0 0.4 0.4 36 5 32 305 38 0 38 0 -20.6 0.1 -20.2 -20.8 02/17/2005 10:20:00 18.5 1.5 21.4 14.5 18.1 1.5 21.8 14.1 0.4 0 0.4 0.4 34 4 34 305 38 0 38 0 -20.6 0 -20.4 -20.8 02/17/2005 10:30:00 18.8 1.3 22.9 15.6 18.4 1.5 22.1 13.7 0.4 0 0.4 0.4 38 5 40 305 38 0 38 0 -20.5 0 -20.2 -20.8 02/17/2005 10:40:00 19.1 1.4 22.1 15.3 19 1.5 22.9 14.5 0.4 0 0.4 0.4 38 5 42 305 38 0 39 0 -20.4 0 -20.1 -20.6 02/17/2005 10:50:00 18.8 1.7 22.6 14.5 18.6 1.7 22.6 14.1 0.4 0 0.4 0.4 37 5 34 305 39 0 39 0 -20.3 0 -20.1 -20.6 02/17/2005 11:00:00 18.3 1.3 22.1 14.9 18.1 1.5 22.9 14.9 0.4 0 0.4 0.4 38 5 42 305 39 0 39 0 -20.3 0.1 -20.1 -20.6 02/17/2005 11:10:00 17.6 1.7 21 13.3 17.3 1.8 20.6 13 0.4 0 0.4 0.4 37 5 35 305 39 0 39 0 -20.2 0.1 -19.9 -20.4 02/17/2005 11:20:00 18.7 1.4 22.6 14.5 18.5 1.4 22.1 13.7 0.4 0 0.4 0.4 37 4 39 305 39 0 40 0 -20.4 0.1 -20.1 -20.6 02/17/2005 11:30:00 18.1 1.5 21.4 13.7 17.8 1.5 21 14.1 0.4 0 0.4 0.4 35 5 39 305 39 0 39 0 -20.3 0.1 -19.9 -20.6 02/17/2005 11:40:00 17.5 1.7 21 12.6 17.3 1.7 20.6 13 0.4 0 0.4 0.4 36 6 31 305 40 0 40 0 -20.2 0.1 -19.9 -20.6 02/17/2005 11:50:00 19.5 1.2 22.6 15.6 19.2 1.2 22.6 15.6 0.4 0 0.4 0.4 37 4 35 305 40 0 40 0 -20.2 0 -20.1 -20.4 02/17/2005 12:00:00 18.7 1.5 22.6 14.9 18.4 1.7 22.1 14.5 0.4 0 0.4 0.4 37 5 38 305 40 0 40 0 -20.2 0 -19.9 -20.4 02/17/2005 12:10:00 19.3 1.5 22.6 15.3 19 1.5 22.1 14.5 0.4 0 0.4 0.4 39 5 36 305 40 0 40 0 -20.1 0 -19.9 -20.1 02/17/2005 12:20:00 18.6 1.7 22.1 14.1 18.3 1.7 22.6 13.7 0.4 0 0.4 0.4 37 5 40 305 41 0 40 0 -20 0.1 -19.9 -20.1 02/17/2005 12:30:00 18.6 1.4 22.1 14.9 18.4 1.5 21.8 14.5 0.4 0 0.4 0.4 35 5 39 305 41 0 41 0 -19.9 0 -19.7 -20.1 02/17/2005 12:40:00 17.8 1.7 21 13.3 17.6 1.7 21.4 13 0.4 0 0.4 0.4 38 5 40 305 42 0 42 0 -19.8 0.1 -19.3 -20.1 02/17/2005 12:50:00 18.6 1.8 22.6 14.5 18.2 1.8 22.1 14.1 0.4 0 0.4 0.4 31 5 30 305 42 0 42 0 -19.6 0 -19.3 -19.9 02/17/2005 13:00:00 19 1.8 22.6 13.3 18.5 1.9 22.6 14.5 0.4 0 0.4 0.4 33 6 36 305 43 0 43 0 -19.6 0.1 -19.2 -19.9 02/17/2005 13:10:00 20.1 2 23.7 15.3 19.6 1.9 23.7 15.3 0.4 0 0.4 0.4 34 5 33 305 43 0 43 0 -19.6 0 -19.3 -19.7 02/17/2005 13:20:00 18.5 1.8 22.6 14.5 18.2 2 22.1 14.5 0.4 0 0.4 0.4 35 5 36 305 44 0 43 0 -19.4 0.1 -19 -19.5 02/17/2005 13:30:00 18.5 1.8 22.9 13.7 18.1 1.8 22.9 13.7 0.4 0 0.4 0.4 35 6 35 305 44 0 45 0 -19.3 0.1 -19 -19.5 02/17/2005 13:40:00 18.8 1.6 22.9 14.5 18.4 1.7 22.1 13.7 0.4 0 0.4 0.4 38 5 37 305 45 0 45 0 -19.4 0 -19 -19.5 02/17/2005 13:50:00 19.6 1.6 22.6 15.3 19.3 1.7 22.9 14.1 0.4 0 0.4 0.4 37 5 40 305 45 0 45 0 -19.4 0 -19 -19.5 02/17/2005 14:00:00 19.2 1.9 23.3 13.7 18.8 1.8 22.9 14.5 0.4 0 0.4 0.4 38 5 36 305 45 0 45 0 -19.3 0.1 -19 -19.5 02/17/2005 14:10:00 18.5 1.4 21.8 14.1 18.2 1.5 21.8 14.1 0.4 0 0.4 0.4 36 5 40 305 45 0 45 0 -19.2 0.1 -19 -19.5 02/17/2005 14:20:00 19.7 1.5 22.6 15.6 19.4 1.6 22.6 14.5 0.4 0 0.4 0.4 35 5 28 305 45 0 45 0 -19.4 0.1 -19 -19.5 02/17/2005 14:30:00 19.7 1.7 23.3 15.3 19.2 1.7 23.3 14.5 0.4 0 0.4 0.4 34 5 31 305 45 0 45 0 -19.4 0 -19 -19.5 02/17/2005 14:40:00 18.5 1.7 22.9 14.1 18.2 1.7 22.6 14.1 0.4 0 0.4 0.4 38 5 35 305 45 0 45 0 -19.2 0 -19 -19.5 02/17/2005 14:50:00 19.7 1.5 23.3 15.6 19.3 1.5 23.3 15.3 0.4 0 0.4 0.4 36 6 26 305 45 0 45 0 -19.3 0.1 -19 -19.5 02/17/2005 15:00:00 19.8 1.4 22.6 15.6 19.5 1.5 22.9 15.6 0.4 0 0.4 0.4 36 5 36 305 45 0 45 0 -19.3 0 -19 -19.5 02/17/2005 15:10:00 18.4 1.5 22.1 14.9 18 1.5 21.8 14.1 0.4 0 0.4 0.4 33 5 30 305 45 0 45 0 -19.1 0 -19 -19.2 02/17/2005 15:20:00 18.6 1.6 22.6 14.5 18.2 1.7 22.1 13.7 0.4 0 0.4 0.4 35 4 42 305 46 0 46 0 -19 0 -18.8 -19 02/17/2005 15:30:00 17.6 1.5 21.4 14.1 17.3 1.6 21 13 0.4 0 0.4 0.4 34 5 37 305 46 0 46 0 -18.9 0 -18.8 -19 02/17/2005 15:40:00 17.4 1.6 21 13.7 17.1 1.7 21 12.6 0.4 0 0.4 0.4 32 5 35 305 46 0 47 0 -18.8 0 -18.4 -19 02/17/2005 15:50:00 18.5 1.5 22.1 13.7 17.9 1.5 21.4 13.3 0.4 0 0.4 0.4 31 4 32 305 47 0 47 0 -18.9 0 -18.8 -19 02/17/2005 16:00:00 19.1 1.5 22.1 14.9 18.7 1.5 22.1 14.1 0.4 0 0.4 0.4 32 4 36 305 47 0 47 0 -18.9 0 -18.6 -19 02/17/2005 16:10:00 19.7 1.7 23.3 14.5 19.2 1.7 22.9 13.7 0.4 0 0.4 0.4 33 5 33 305 47 0 47 0 -18.8 0 -18.6 -19 02/17/2005 16:20:00 20.4 1.4 24 16.8 19.9 1.5 24 15.6 0.4 0 0.4 0.4 34 4 32 305 47 0 47 0 -18.8 0 -18.4 -19 02/17/2005 16:30:00 19.1 1.6 23.3 15.3 18.6 1.6 22.9 14.5 0.4 0 0.4 0.4 35 4 40 305 47 0 47 0 -18.6 0 -18.4 -18.8 02/17/2005 16:40:00 18.1 1.2 20.6 14.1 17.7 1.3 20.6 13.7 0.4 0 0.4 0.4 34 5 38 305 48 0 48 0 -18.5 0 -18.4 -18.4 02/17/2005 16:50:00 18 1.4 21.8 14.9 17.7 1.5 21.4 14.1 0.4 0 0.4 0.4 36 4 33 305 48 0 48 0 -18.5 0 -18.2 -18.6 02/17/2005 17:00:00 19.2 1.4 22.6 15.6 19 1.5 22.6 14.1 0.4 0 0.4 0.4 36 4 39 305 49 0 49 0 -18.5 0 -18.2 -18.4 02/17/2005 17:10:00 18.8 1.2 22.9 15.3 18.6 1.3 22.6 14.5 0.4 0 0.4 0.4 37 5 35 305 49 0 49 0 -18.3 0 -18.1 -18.4 02/17/2005 17:20:00 20.2 1.6 23.3 14.9 19.9 1.7 23.3 14.5 0.4 0 0.4 0.4 41 5 44 305 49 0 49 0 -18.2 0 -17.9 -18.4 02/17/2005 17:30:00 20.9 1.7 24.4 16.4 20.4 1.7 24 16.1 0.4 0 0.4 0.4 37 4 38 305 50 0 50 0 -18.2 0.1 -17.9 -18.4 02/17/2005 17:40:00 20.3 1.5 23.7 15.6 19.9 1.5 23.7 16.1 0.4 0 0.4 0.4 36 5 35 305 50 0 50 0 -18.1 0 -17.9 -18.4 02/17/2005 17:50:00 19.3 1.8 22.9 14.9 19 1.9 23.7 14.9 0.4 0 0.4 0.4 37 5 30 305 50 0 50 0 -18 0 -17.7 -18.2 02/17/2005 18:00:00 18.6 1.3 21.4 14.5 18.3 1.5 21.8 14.5 0.4 0 0.4 0.4 35 5 35 305 50 0 51 0 -18 0 -17.7 -18.1 02/17/2005 18:10:00 19.1 1.4 22.6 15.3 18.9 1.4 22.1 14.9 0.4 0 0.4 0.4 37 5 31 305 51 0 51 0 -17.9 0.1 -17.5 -18.1 02/17/2005 18:20:00 19.3 1.4 22.9 15.3 18.9 1.5 22.1 14.5 0.4 0 0.4 0.4 35 5 26 305 51 0 51 0 -17.9 0.1 -17.5 -18.1 02/17/2005 18:30:00 17.7 1.3 20.2 14.5 17.5 1.4 20.6 14.1 0.4 0 0.4 0.4 38 5 44 305 51 0 52 0 -17.7 0 -17.5 -17.9 02/17/2005 18:40:00 18.9 1.8 22.1 13.7 18.6 1.9 22.1 13 0.4 0 0.4 0.4 36 4 39 305 52 0 52 0 -17.7 0 -17.3 -17.9 02/17/2005 18:50:00 19.2 1.6 23.3 14.5 18.7 1.7 22.6 14.5 0.4 0 0.4 0.4 34 4 31 305 52 0 52 0 -17.6 0 -17.3 -17.9 02/17/2005 19:00:00 19.8 1.4 22.9 16.1 19.4 1.5 23.7 15.3 0.4 0 0.4 0.4 35 4 31 305 52 0 52 0 -17.6 0.1 -17.3 -17.7 02/17/2005 19:10:00 19.2 1.5 22.1 15.3 18.7 1.5 22.1 14.9 0.4 0 0.4 0.4 34 5 35 305 52 0 52 0 -17.5 0 -17.1 -17.7 02/17/2005 19:20:00 19.1 1.3 21.8 14.9 18.7 1.4 21.4 14.9 0.4 0 0.4 0.4 35 4 43 305 52 0 52 0 -17.4 0 -16.9 -17.5 02/17/2005 19:30:00 19.4 1.4 22.9 15.6 19.2 1.5 22.6 15.6 0.4 0 0.4 0.4 36 4 39 305 53 0 53 0 -17.3 0.1 -16.9 -17.5 02/17/2005 19:40:00 19.4 1.5 24 15.3 19 1.5 22.9 14.9 0.4 0 0.4 0.4 38 5 40 305 54 0 54 0 -17.1 0 -16.9 -17.3 02/17/2005 19:50:00 20.9 1.6 24.8 16.8 20.7 1.7 24.4 16.4 0.4 0 0.4 0.4 40 4 40 305 54 0 54 0 -17 0 -16.9 -17.3 02/17/2005 20:00:00 21.7 1.7 25.6 17.2 21.3 1.7 25.2 16.8 0.4 0 0.4 0.4 39 4 40 305 55 0 55 0 -16.9 0 -16.6 -16.9 02/17/2005 20:10:00 19.9 2.2 24.8 14.9 19.6 2.2 24.4 14.5 0.4 0 0.4 0.4 40 5 49 305 55 0 55 0 -16.8 0 -16.4 -16.9 02/17/2005 20:20:00 18.9 1.8 22.9 14.5 18.5 1.9 22.9 13.3 0.4 0 0.4 0.4 38 5 39 305 56 0 56 0 -16.7 0.1 -16.4 -16.9 02/17/2005 20:30:00 19.6 1.7 22.9 14.1 19.2 1.7 22.6 14.5 0.4 0 0.4 0.4 35 5 31 305 56 0 56 0 -16.8 0.1 -16.6 -16.9 02/17/2005 20:40:00 19.8 1.7 22.9 14.5 19.5 1.7 22.6 14.1 0.4 0 0.4 0.4 36 5 31 305 57 0 57 0 -16.8 0 -16.4 -16.9 02/17/2005 20:50:00 20.9 1.5 23.7 16.1 20.6 1.6 24 16.4 0.4 0 0.4 0.4 38 4 38 305 57 0 57 0 -16.8 0 -16.4 -16.9 02/17/2005 21:00:00 19.7 1.3 23.3 14.9 19.4 1.4 22.6 14.5 0.4 0 0.4 0.4 36 4 31 305 57 0 57 0 -16.9 0 -16.4 -16.9 02/17/2005 21:10:00 19.3 1.5 22.6 15.3 18.7 1.5 22.6 14.5 0.4 0 0.4 0.4 35 5 30 305 57 0 57 0 -16.9 0 -16.6 -16.9 02/17/2005 21:20:00 20.7 1.1 23.7 17.2 20.3 1.2 23.3 16.8 0.4 0 0.4 0.4 36 4 32 305 57 0 57 0 -16.9 0 -16.9 -16.9 02/17/2005 21:30:00 19.4 1.5 22.9 15.3 19 1.5 22.6 14.9 0.4 0 0.4 0.4 37 5 30 305 57 0 57 0 -16.8 0.1 -16.6 -16.9 02/17/2005 21:40:00 18.8 1.7 23.7 15.3 18.5 1.8 23.7 14.5 0.4 0 0.4 0.4 37 5 36 305 57 0 57 0 -16.6 0 -16.4 -16.9 02/17/2005 21:50:00 20.5 1.5 23.3 16.8 20.3 1.5 23.3 16.4 0.4 0 0.4 0.4 39 4 41 305 57 0 58 0 -16.6 0 -16.2 -16.9 02/17/2005 22:00:00 20.5 1.4 24.4 16.8 20.1 1.5 24.8 16.4 0.4 0 0.4 0.4 41 5 38 305 58 0 58 0 -16.6 0 -16.2 -16.9 02/17/2005 22:10:00 21.3 1.6 25.2 17.2 21 1.7 25.2 16.4 0.4 0 0.4 0.4 40 4 39 305 58 0 58 0 -16.6 0.1 -16.2 -16.9 02/17/2005 22:20:00 20.5 1.3 23.7 16.4 20 1.5 23.3 14.9 0.4 0 0.4 0.4 39 4 41 305 58 0 58 0 -16.6 0.1 -16 -16.9 02/17/2005 22:30:00 20.5 1.5 24.4 17.2 20.1 1.6 24 16.4 0.4 0 0.4 0.4 36 4 41 305 58 0 58 0 -16.4 0 -16 -16.6 02/17/2005 22:40:00 20.1 1.5 23.7 15.3 19.8 1.6 23.3 15.6 0.4 0 0.4 0.4 36 4 39 305 58 0 58 0 -16.4 0 -16 -16.6 02/17/2005 22:50:00 20.9 1.4 23.7 17.2 20.5 1.5 23.7 16.8 0.4 0 0.4 0.4 35 4 33 305 58 0 58 0 -16.4 0 -16 -16.6 02/17/2005 23:00:00 20.4 1.9 24 15.6 19.8 2 24.4 14.5 0.4 0 0.4 0.4 35 4 36 305 58 0 59 0 -16.4 0 -16 -16.6 02/17/2005 23:10:00 19.5 1.3 22.6 16.1 19.2 1.4 22.6 15.3 0.4 0 0.4 0.4 37 4 32 305 59 0 59 0 -16.4 0 -16 -16.6 02/17/2005 23:20:00 20.7 1.5 23.7 15.6 20.1 1.7 24 15.3 0.4 0 0.4 0.4 33 4 33 305 59 0 59 0 -16.4 0.1 -16 -16.6 02/17/2005 23:30:00 19.9 1.4 23.7 16.8 19.4 1.5 23.3 15.6 0.4 0 0.4 0.4 36 5 37 305 59 0 59 0 -16.2 0.1 -15.8 -16.4 02/17/2005 23:40:00 20.3 1.6 24.4 16.4 19.9 1.7 24 16.1 0.4 0 0.4 0.4 37 5 37 305 59 0 59 0 -16.3 0.1 -15.8 -16.4 02/17/2005 23:50:00 18.9 1.3 22.6 14.5 18.6 1.4 22.6 14.1 0.4 0 0.4 0.4 37 4 37 305 59 0 60 0 -16.2 0.1 -15.8 -16.4 02/18/2005 00:00:00 18.8 1.5 22.6 15.3 18.6 1.5 21.4 14.9 0.4 0 0.4 0.4 38 5 43 305 59 0 59 0 -16.1 0.1 -15.8 -16.4 02/18/2005 00:10:00 19.4 1.5 22.6 15.6 18.9 1.5 22.6 15.3 0.4 0 0.4 0.4 35 5 38 305 60 0 60 0 -16.2 0.1 -15.8 -16.4 02/18/2005 00:20:00 18.8 1.6 22.6 14.5 18.5 1.7 22.1 14.1 0.4 0 0.4 0.4 37 5 41 305 60 0 60 0 -16.3 0 -16 -16.4 02/18/2005 00:30:00 18 1.2 20.6 13.7 17.6 1.3 20.2 13.3 0.4 0 0.4 0.4 34 4 41 305 59 0 60 0 -16.3 0 -16 -16.6 02/18/2005 00:40:00 17.5 1.7 22.1 12.6 17.1 1.7 21 12.6 0.4 0 0.4 0.4 37 5 39 305 59 0 59 0 -16.2 0 -15.8 -16.4 02/18/2005 00:50:00 18.3 2 22.6 14.5 18 2 22.6 13.7 0.4 0 0.4 0.4 36 5 40 305 59 0 60 0 -16.1 0 -15.8 -16.4 02/18/2005 01:00:00 19.7 1.4 22.9 15.3 19.4 1.5 22.9 15.6 0.4 0 0.4 0.4 38 4 38 305 60 0 60 0 -16.1 0.1 -15.8 -16.4 02/18/2005 01:10:00 18.9 1.5 21.8 15.6 18.7 1.7 21.8 14.9 0.4 0 0.4 0.4 39 5 43 305 60 0 60 0 -16.1 0 -15.8 -16.4 02/18/2005 01:20:00 18.5 1.3 22.1 15.3 18.3 1.3 21.8 15.3 0.4 0 0.4 0.4 39 5 42 305 60 0 60 0 -16.1 0 -15.8 -16.4 02/18/2005 01:30:00 18.4 1.4 21.4 14.5 18 1.4 21 14.9 0.4 0 0.4 0.4 35 4 30 305 60 0 60 0 -16.1 0 -16 -16.2 02/18/2005 01:40:00 17.8 1.3 21.4 14.5 17.5 1.4 21.4 13.7 0.4 0 0.4 0.4 37 4 33 305 60 0 60 0 -16.1 0 -15.8 -16.2 02/18/2005 01:50:00 16.5 1.4 20.6 13 16.2 1.5 19.9 12.6 0.4 0 0.4 0.4 35 5 45 305 60 0 60 0 -16 0 -15.8 -16.2 02/18/2005 02:00:00 16.7 1.7 20.6 13.3 16.4 1.7 20.6 13 0.4 0 0.4 0.4 35 4 40 305 60 0 60 0 -15.9 0 -15.6 -16.2 02/18/2005 02:10:00 17.6 1.5 21.4 13.3 17.3 1.5 20.6 13.7 0.4 0 0.4 0.4 35 4 42 305 60 0 61 0 -15.8 0 -15.6 -16 02/18/2005 02:20:00 16.5 1.5 19.9 13 16.3 1.4 20.2 13 0.4 0 0.4 0.4 37 5 36 305 61 0 61 0 -15.8 0 -15.4 -15.8 02/18/2005 02:30:00 17.8 1.3 21.4 14.1 17.5 1.5 21 13.3 0.4 0 0.4 0.4 35 5 39 305 62 0 62 0 -15.7 0.1 -15.2 -15.8 02/18/2005 02:40:00 17.5 1.7 21.4 13.7 17.2 1.6 20.6 13.7 0.4 0 0.4 0.4 34 5 33 305 62 0 62 0 -15.7 0.1 -15.2 -15.8 02/18/2005 02:50:00 17.4 1.6 22.1 13.7 17 1.5 21.4 13.3 0.4 0 0.4 0.4 34 5 33 305 62 0 62 0 -15.7 0.1 -15.2 -15.8 02/18/2005 03:00:00 18 1.5 21.8 14.1 17.7 1.5 22.1 13.7 0.4 0 0.4 0.4 34 5 33 305 62 0 63 0 -15.7 0.1 -15.2 -15.8 02/18/2005 03:10:00 19 1.5 23.7 14.9 18.5 1.6 22.9 14.1 0.4 0 0.4 0.4 32 5 30 305 63 0 63 0 -15.8 0.1 -15.2 -15.8 02/18/2005 03:20:00 18.1 1.6 22.6 14.1 17.8 1.5 21.4 13.7 0.4 0 0.4 0.4 30 5 35 305 63 0 63 0 -15.8 0 -15.2 -16 02/18/2005 03:30:00 17.1 2 22.9 11.5 16.7 1.9 22.1 11.8 0.4 0 0.4 0.4 32 5 25 305 63 0 63 0 -15.8 0 -15.4 -16 02/18/2005 03:40:00 17.3 1.7 21.4 13.3 17 1.7 20.6 13.7 0.4 0 0.4 0.4 34 6 35 305 62 0 63 0 -15.8 0 -15.2 -16 02/18/2005 03:50:00 17.6 1.9 22.1 13 17.4 1.8 22.1 13.3 0.4 0 0.4 0.4 34 6 30 305 62 0 63 0 -15.8 0 -15.2 -16 02/18/2005 04:00:00 16.6 1.8 22.6 12.6 16.3 1.7 22.1 12.2 0.4 0 0.4 0.4 32 6 35 305 62 0 62 0 -15.8 0 -15.2 -15.8 02/18/2005 04:10:00 17.2 1.6 21 13.7 16.9 1.5 20.2 13 0.4 0 0.4 0.4 32 5 31 305 62 0 62 0 -15.8 0 -15.2 -16 02/18/2005 04:20:00 18.3 1.8 22.9 13.7 17.8 1.8 22.1 13 0.4 0 0.4 0.4 29 5 22 305 62 0 63 0 -15.8 0 -15.4 -16 02/18/2005 04:30:00 16.3 2.2 22.6 12.2 16 2.1 21.8 12.2 0.4 0 0.4 0.4 32 6 40 305 62 0 62 0 -15.8 0 -15.2 -15.8 02/18/2005 04:40:00 18.3 1.8 22.6 13 18 1.8 22.1 13 0.4 0 0.4 0.4 35 5 26 305 62 0 62 0 -15.8 0.1 -15.2 -16 02/18/2005 04:50:00 18.4 1.7 22.6 14.5 18.3 1.7 23.7 14.1 0.4 0 0.4 0.4 35 5 34 305 62 0 63 0 -15.7 0.1 -15 -15.8 02/18/2005 05:00:00 19.2 1.9 23.7 14.1 19.1 1.9 23.3 14.1 0.4 0 0.4 0.4 36 5 34 305 63 0 63 0 -15.6 0 -15.2 -15.8 02/18/2005 05:10:00 18.4 1.7 22.6 14.1 18.3 1.7 22.6 13.7 0.4 0 0.4 0.4 36 5 38 305 63 0 63 0 -15.6 0 -15.4 -15.8 02/18/2005 05:20:00 19.1 1.6 24 15.6 19 1.7 23.3 14.9 0.4 0 0.4 0.4 36 6 30 305 63 0 63 0 -15.7 0 -15.6 -15.8 02/18/2005 05:30:00 18.5 1.7 22.1 14.1 18.4 1.7 22.1 13.7 0.4 0 0.4 0.4 36 5 32 305 63 0 63 0 -15.8 0 -15.6 -16 02/18/2005 05:40:00 18.7 1.5 22.1 14.9 18.7 1.5 22.6 14.5 0.4 0 0.4 0.4 37 5 40 305 62 0 63 0 -15.8 0 -15.6 -15.8 02/18/2005 05:50:00 17.9 1.5 21.8 13.3 17.9 1.6 22.1 13.7 0.4 0 0.4 0.4 37 6 26 305 62 0 63 0 -15.8 0 -15.6 -16 02/18/2005 06:00:00 18.2 1.5 21.8 14.9 18.2 1.6 22.1 15.3 0.4 0 0.4 0.4 33 5 36 305 62 0 63 0 -15.8 0 -15.6 -16 02/18/2005 06:10:00 16.9 1.5 20.2 13.3 16.8 1.6 21 13 0.4 0 0.4 0.4 32 5 31 305 62 0 63 0 -15.8 0 -15.6 -16 02/18/2005 06:20:00 16.7 1.5 20.6 12.6 16.7 1.7 21 11.5 0.4 0 0.4 0.4 33 6 33 305 62 0 63 0 -15.9 0 -15.6 -16 02/18/2005 06:30:00 16.5 1.7 20.6 12.6 16.4 1.7 21 12.2 0.4 0 0.4 0.4 29 5 32 305 62 0 63 0 -16 0 -15.8 -16.2 02/18/2005 06:40:00 15.1 1.5 19.9 11.5 15 1.6 19.5 11.1 0.4 0 0.4 0.4 31 6 32 305 62 0 62 0 -16.2 0 -16 -16.4 02/18/2005 06:50:00 15.8 2.1 21 11.8 15.6 2 20.6 11.8 0.4 0 0.4 0.4 30 6 23 305 61 0 62 0 -16.2 0 -16 -16.4 02/18/2005 07:00:00 15.5 1.4 20.2 12.2 15.4 1.4 18.7 11.8 0.4 0 0.4 0.4 31 6 25 305 61 0 61 0 -16.2 0.1 -15.8 -16.4 02/18/2005 07:10:00 15.6 1.7 19.9 11.8 15.6 1.7 20.2 11.1 0.4 0 0.4 0.4 33 6 37 305 60 0 60 0 -16.2 0.1 -15.8 -16.4 02/18/2005 07:20:00 16.9 1.5 20.6 13.7 16.8 1.5 20.6 13 0.4 0 0.4 0.4 32 4 33 305 60 0 60 0 -16.1 0.1 -15.8 -16.4 02/18/2005 07:30:00 16.7 1.5 20.2 12.6 16.6 1.6 19.9 11.8 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -16.2 0.1 -15.8 -16.4 02/18/2005 07:40:00 15.4 1.7 20.2 11.5 15.2 1.7 20.2 11.5 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -16.2 0.1 -15.8 -16.4 02/18/2005 07:50:00 15.9 1.8 21 12.2 15.9 1.7 19.9 12.2 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -16.2 0.1 -15.8 -16.4 02/18/2005 08:00:00 15.9 1.7 20.6 12.2 15.7 1.7 20.2 12.2 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -16.2 0.1 -15.6 -16.4 02/18/2005 08:10:00 15.7 1.7 20.2 11.8 15.5 1.6 19.5 11.5 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -16.3 0 -16 -16.6 02/18/2005 08:20:00 16.3 1.4 19.9 12.2 16.1 1.3 19.5 12.6 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.4 0 -16 -16.6 02/18/2005 08:30:00 16 1.9 21 11.5 15.8 1.9 21.8 11.1 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.3 0 -15.8 -16.6 02/18/2005 08:40:00 16.4 2 22.1 11.8 16.1 2 22.1 11.8 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.2 0.1 -15.8 -16.4 02/18/2005 08:50:00 15 1.6 19.1 11.1 14.8 1.7 19.1 10.3 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.2 0.1 -15.8 -16.4 02/18/2005 09:00:00 15.8 2 20.6 10.7 15.6 2 20.6 10.7 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.2 0.1 -15.8 -16.4 02/18/2005 09:10:00 15.8 2 21.8 11.1 15.6 2 21.8 11.5 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.3 0 -16 -16.6 02/18/2005 09:20:00 16.3 1.5 21 13 16.1 1.7 21 12.6 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.5 0 -16.4 -16.6 02/18/2005 09:30:00 17.1 1.7 21 12.6 16.8 1.7 21.4 13 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.5 0 -16.4 -16.6 02/18/2005 09:40:00 15.9 2.1 21.8 11.5 15.6 2.1 21 10.7 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.5 0 -16.4 -16.6 02/18/2005 09:50:00 16.4 1.8 20.2 11.8 16.3 2 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.6 0 -16.4 -16.9 02/18/2005 10:00:00 16.5 1.7 21.4 12.2 16.4 1.7 19.9 11.8 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.7 0.1 -16.4 -16.9 02/18/2005 10:10:00 16.7 1.7 21 11.8 16.5 1.8 21 11.5 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.7 0.1 -16.4 -16.9 02/18/2005 10:20:00 16.8 1.7 20.6 11.8 16.6 1.6 20.6 11.8 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.7 0 -16.4 -16.9 02/18/2005 10:30:00 17.3 1.7 21 13.3 16.9 1.7 21 12.6 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.6 0 -16.4 -16.7 02/18/2005 10:40:00 16 1.6 20.2 11.8 15.7 1.6 19.9 11.8 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.6 0.1 -16.2 -16.7 02/18/2005 10:50:00 17.4 1.7 21.4 11.8 16.9 1.8 21.8 12.2 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.7 0.1 -16.4 -16.9 02/18/2005 11:00:00 16.2 1.5 20.2 12.6 16.1 1.5 19.9 12.2 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.7 0.1 -16.4 -16.9 02/18/2005 11:10:00 15.3 1.5 19.5 11.8 15.2 1.6 19.5 11.5 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.7 0 -16.6 -16.9 02/18/2005 11:20:00 15.1 2.3 19.9 10.3 14.9 2.3 20.2 10.3 0.4 0 0.4 0.4 31 0 31 305 57 0 58 0 -16.7 0 -16.6 -16.9 02/18/2005 11:30:00 15.8 1.9 20.6 11.5 15.6 1.8 20.6 10.7 0.4 0 0.4 0.4 31 0 31 305 57 0 58 0 -16.7 0 -16.2 -16.9 02/18/2005 11:40:00 15.9 1.7 19.9 10.7 15.7 1.6 19.9 11.1 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.4 0.1 -16 -16.6 02/18/2005 11:50:00 16.6 2 22.9 12.6 16.6 1.9 22.6 11.8 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.4 0 -16 -16.6 02/18/2005 12:00:00 17 1.5 21 13.7 17 1.6 21.4 13 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.5 0 -16.2 -16.7 02/18/2005 12:10:00 17.4 1.7 21 13.3 17.4 1.7 21.8 12.6 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.6 0 -16.4 -16.9 02/18/2005 12:20:00 16 1.4 19.5 12.6 16 1.5 19.9 13 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.4 0 -16 -16.6 02/18/2005 12:30:00 16.8 1.5 21 12.6 16.7 1.6 21 12.2 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.5 0 -16.2 -16.6 02/18/2005 12:40:00 17.9 2 22.6 12.2 17.7 2 22.6 13 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.7 0.1 -16.2 -16.9 02/18/2005 12:50:00 17.7 1.9 24.4 13.7 17.5 1.8 23.3 13 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.6 0 -16.2 -16.9 02/18/2005 13:00:00 17.8 1.7 22.1 12.6 17.8 1.7 22.1 13.3 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.6 0 -16.2 -16.9 02/18/2005 13:10:00 17.6 2.2 22.6 13.3 17.5 2.1 23.3 12.6 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.6 0 -16.2 -16.9 02/18/2005 13:20:00 17.9 1.5 22.1 14.1 17.8 1.7 22.6 13.7 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.6 0 -16.2 -16.7 02/18/2005 13:30:00 16.8 1.9 21 12.6 16.9 1.8 21.4 12.6 0.4 0 0.4 0.4 31 0 31 305 57 0 58 0 -16.4 0 -16 -16.6 02/18/2005 13:40:00 17.6 2.1 22.6 13 17.4 2.2 22.6 13 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.4 0 -16 -16.6 02/18/2005 13:50:00 19 1.8 23.3 13.3 18.7 1.8 23.3 13.7 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.6 0 -16.4 -16.7 02/18/2005 14:00:00 18.4 2.2 24 14.1 18.2 2.3 24.4 14.1 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.6 0 -16.4 -16.7 02/18/2005 14:10:00 17.5 2.3 22.9 11.5 17.5 2.3 22.9 11.8 0.4 0 0.4 0.4 31 0 31 305 59 0 58 0 -16.5 0 -16.4 -16.6 02/18/2005 14:20:00 17.8 1.8 22.9 12.6 17.6 1.8 22.6 13 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.5 0 -16.4 -16.6 02/18/2005 14:30:00 18.3 2.2 23.7 12.6 18.1 2.2 24 12.6 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.5 0 -16 -16.6 02/18/2005 14:40:00 18.1 2.4 24 12.6 18 2.4 24 12.6 0.4 0 0.4 0.4 31 0 31 305 58 0 59 0 -16.5 0 -16.4 -16.6 02/18/2005 14:50:00 17.3 1.7 21.8 13.3 17.1 1.7 21.8 13 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.4 0 -16.2 -16.6 02/18/2005 15:00:00 17.7 1.9 22.9 11.8 17.6 2 22.6 12.6 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.6 0 -16.4 -16.7 02/18/2005 15:10:00 16.6 2.1 22.1 12.6 16.5 2.1 21.8 11.8 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.5 0 -16.4 -16.6 02/18/2005 15:20:00 15.2 2.2 19.5 10.3 15.3 2.3 19.5 10.3 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.4 0 -16.2 -16.6 02/18/2005 15:30:00 16.2 1.7 21.8 12.6 16.1 1.7 21.8 11.5 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -16.4 0 -16.4 -16.6 02/18/2005 15:40:00 17.1 2.4 22.6 11.5 17.1 2.5 22.6 11.1 0.4 0 0.4 0.4 31 0 31 305 58 0 59 0 -16.5 0 -16.4 -16.6 02/18/2005 15:50:00 17.3 1.9 22.6 12.6 17.2 1.8 22.1 13 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.5 0 -16.4 -16.7 02/18/2005 16:00:00 15.9 2.1 21.8 11.1 15.7 2.1 22.1 11.5 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16.6 0 -16.2 -16.7 02/18/2005 16:10:00 14.8 1.8 19.5 10.7 14.9 1.7 19.9 11.1 0.4 0 0.4 0.4 31 0 31 305 57 0 58 0 -16.7 0.1 -16.2 -16.9 02/18/2005 16:20:00 15.6 2.4 21.8 10.7 15.4 2.5 21.4 10.7 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.7 0.1 -16.4 -16.9 02/18/2005 16:30:00 14.9 2 19.5 9.5 14.8 2.1 19.9 9.9 0.4 0 0.4 0.4 31 0 31 305 56 0 57 0 -16.7 0.1 -16.4 -16.9 02/18/2005 16:40:00 13.4 2.4 17.9 7.6 13.5 2.4 18.3 7.2 0.4 0 0.4 0.4 31 0 31 305 56 0 56 0 -16.8 0.1 -16.4 -16.9 02/18/2005 16:50:00 12.5 2.2 18.7 8.4 12.6 2.2 18.3 8.8 0.4 0 0.4 0.4 31 0 31 305 56 0 56 0 -16.8 0.1 -16.4 -16.9 02/18/2005 17:00:00 12 1.6 16.8 8.4 12.1 1.7 18.3 8.4 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -16.9 0 -16.4 -16.9 02/18/2005 17:10:00 14.1 2 19.9 10.3 14.3 2 20.2 10.7 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -16.8 0 -16.4 -16.9 02/18/2005 17:20:00 16.4 1.7 20.2 11.8 16.5 1.7 20.2 11.8 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -16.9 0 -16.4 -16.9 02/18/2005 17:30:00 13.6 1.4 17.6 10.3 13.5 1.4 17.9 9.9 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -16.8 0.1 -16.4 -16.9 02/18/2005 17:40:00 14.1 1.7 18.3 10.7 14.2 1.7 18.3 10.3 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -16.7 0.1 -16.4 -16.9 02/18/2005 17:50:00 12.2 1.3 16.1 8.8 12.3 1.5 16.8 8.4 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -16.7 0.1 -16.4 -16.9 02/18/2005 18:00:00 14.8 1.3 18.3 10.7 14.8 1.3 17.9 11.8 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -16.8 0.1 -16.4 -16.9 02/18/2005 18:10:00 15.3 1.3 19.1 10.7 15.2 1.3 18.7 11.5 0.4 0 0.4 0.4 31 0 31 305 55 0 54 0 -16.9 0 -16.6 -16.9 02/18/2005 18:20:00 16.1 1.7 20.2 12.2 16 1.7 20.6 11.5 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -16.9 0 -16.6 -16.9 02/18/2005 18:30:00 15.9 1.7 20.2 12.2 15.8 1.7 20.2 11.8 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -16.9 0 -16.9 -17.1 02/18/2005 18:40:00 15.8 1.9 21 11.1 15.8 1.8 20.6 11.5 0.4 0 0.4 0.4 31 0 31 305 53 0 54 0 -17.1 0 -16.9 -17.3 02/18/2005 18:50:00 16.1 1.7 20.2 11.8 16 1.7 20.6 11.5 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -17.1 0.1 -16.9 -17.5 02/18/2005 19:00:00 16.4 1.7 20.6 12.2 16.3 1.7 21 12.2 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -17.2 0 -16.9 -17.5 02/18/2005 19:10:00 17 2 21.4 11.5 16.9 2 21.8 11.1 0.4 0 0.4 0.4 31 0 31 305 52 0 52 0 -17.5 0 -17.1 -17.5 02/18/2005 19:20:00 14.8 2.2 20.2 8.8 14.8 2.1 20.2 8.8 0.4 0 0.4 0.4 31 0 31 305 51 0 52 0 -17.4 0 -17.1 -17.5 02/18/2005 19:30:00 15.2 1.4 18.7 11.5 15.1 1.5 18.7 11.1 0.4 0 0.4 0.4 31 0 31 305 51 0 52 0 -17.5 0 -17.3 -17.7 02/18/2005 19:40:00 15.2 1.7 20.2 10.3 15.2 1.7 19.9 10.3 0.4 0 0.4 0.4 31 0 31 305 51 0 51 0 -17.5 0 -17.3 -17.7 02/18/2005 19:50:00 13.9 1.5 17.2 10.3 13.9 1.5 17.9 10.3 0.4 0 0.4 0.4 31 0 31 305 51 0 51 0 -17.5 0 -17.3 -17.7 02/18/2005 20:00:00 15.1 1.7 19.9 11.5 14.9 1.6 19.1 11.5 0.4 0 0.4 0.4 31 0 31 305 51 0 51 0 -17.5 0 -17.3 -17.7 02/18/2005 20:10:00 16.3 1.5 19.9 12.2 16.1 1.5 19.9 11.8 0.4 0 0.4 0.4 31 0 31 305 50 0 51 0 -17.6 0 -17.3 -17.9 02/18/2005 20:20:00 15.3 1.6 19.5 11.1 15.2 1.7 19.1 11.1 0.4 0 0.4 0.4 31 0 31 305 50 0 50 0 -17.6 0 -17.5 -17.9 02/18/2005 20:30:00 13.1 1.9 19.5 9.9 13 1.9 19.9 9.9 0.4 0 0.4 0.4 31 0 31 305 50 0 50 0 -17.5 0 -17.3 -17.7 02/18/2005 20:40:00 15 1.8 19.1 10.7 15.1 1.8 19.5 11.1 0.4 0 0.4 0.4 31 0 31 305 50 0 50 0 -17.5 0 -17.1 -17.7 02/18/2005 20:50:00 13.5 1.7 17.9 9.1 13.6 1.7 17.9 9.9 0.4 0 0.4 0.4 31 0 31 305 50 0 51 0 -17.4 0 -16.9 -17.5 02/18/2005 21:00:00 13.8 1.6 17.6 10.3 13.9 1.7 17.9 10.3 0.4 0 0.4 0.4 31 0 31 305 51 0 51 0 -17.2 0.1 -16.9 -17.5 02/18/2005 21:10:00 14.5 1.8 19.5 9.9 14.6 1.8 18.7 10.3 0.4 0 0.4 0.4 31 0 31 305 52 0 51 0 -17 0 -16.9 -17.1 02/18/2005 21:20:00 13.4 1.7 17.9 10.7 13.5 1.7 18.3 10.3 0.4 0 0.4 0.4 31 0 31 305 52 0 52 0 -17 0 -16.6 -17.1 02/18/2005 21:30:00 14.7 2 20.6 11.1 14.8 1.9 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 52 0 53 0 -17 0 -16.6 -17.1 02/18/2005 21:40:00 14.2 1.5 18.3 10.7 14.2 1.5 18.7 10.7 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -16.9 0 -16.6 -16.9 02/18/2005 21:50:00 15.3 1.7 20.2 11.8 15.4 1.7 20.2 12.6 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -16.9 0 -16.6 -16.9 02/18/2005 22:00:00 15.4 1.6 18.7 11.1 15.4 1.7 19.5 11.1 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -16.9 0 -16.6 -16.9 02/18/2005 22:10:00 13.2 1.3 16.4 10.3 13.4 1.3 16.8 10.3 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -16.7 0.1 -16.2 -16.9 02/18/2005 22:20:00 14.1 1.5 18.7 11.5 14.1 1.5 19.1 11.1 0.4 0 0.4 0.4 31 0 31 305 54 0 53 0 -16.7 0.1 -16.4 -16.9 02/18/2005 22:30:00 12.6 1.3 16.1 9.5 12.8 1.3 16.4 9.5 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -16.6 0.1 -16 -16.9 02/18/2005 22:40:00 14.1 2.3 20.2 10.3 14.2 2.4 21 10.3 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -16.5 0.1 -16 -16.6 02/18/2005 22:50:00 14.3 1.9 19.5 11.1 14.5 2 19.5 11.5 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -16.4 0 -16 -16.6 02/18/2005 23:00:00 14.6 1.6 18.7 11.1 14.6 1.7 19.1 10.7 0.4 0 0.4 0.4 31 0 31 305 56 0 55 0 -16.4 0 -16 -16.6 02/18/2005 23:10:00 15.8 1.7 21 11.8 15.8 1.7 21.4 11.8 0.4 0 0.4 0.4 31 0 31 305 56 0 56 0 -16.3 0 -16 -16.4 02/18/2005 23:20:00 15.6 1.7 19.9 11.1 15.6 1.9 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 56 0 56 0 -16.3 0 -16 -16.4 02/18/2005 23:30:00 13.7 1.5 17.9 10.3 13.8 1.5 19.1 11.1 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.2 0.1 -16 -16.4 02/18/2005 23:40:00 16.1 1.6 19.9 12.2 16.3 1.6 20.2 11.8 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16 0 -15.8 -16.2 02/18/2005 23:50:00 15.8 1.7 20.2 11.1 15.7 1.7 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16 0 -15.8 -16.2 02/19/2005 00:00:00 15.1 1.6 18.7 11.1 15.2 1.7 19.9 10.7 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16 0 -15.6 -16.2 02/19/2005 00:10:00 14.5 1.7 18.7 10.7 14.6 1.7 18.7 10.7 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16 0 -15.6 -16.2 02/19/2005 00:20:00 14.6 1.4 19.1 11.8 14.6 1.5 19.1 11.5 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -16 0 -15.6 -16.2 02/19/2005 00:30:00 14.6 1.3 18.3 12.2 14.7 1.3 19.1 11.8 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -15.9 0 -15.6 -16.2 02/19/2005 00:40:00 14.9 2 20.2 11.1 15 2 19.9 11.1 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -15.9 0 -15.6 -16 02/19/2005 00:50:00 13.6 1 17.2 11.5 13.8 1.1 16.4 11.1 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -15.8 0 -15.4 -16 02/19/2005 01:00:00 16 1.8 20.2 10.7 16.2 1.8 21 11.8 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -15.8 0 -15.4 -16 02/19/2005 01:10:00 13.6 1.5 17.9 10.3 13.7 1.5 17.9 11.1 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -15.7 0.1 -15.2 -15.8 02/19/2005 01:20:00 13.2 1.1 16.8 11.5 13.3 1.1 16.8 11.1 0.4 0 0.4 0.4 31 0 31 305 59 0 60 0 -15.7 0.1 -15.2 -15.8 02/19/2005 01:30:00 14.4 2 19.5 10.7 14.5 2 19.1 10.3 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -15.6 0 -15 -15.8 02/19/2005 01:40:00 15 1.4 19.1 11.5 15.2 1.4 18.7 11.5 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -15.6 0.1 -15 -15.8 02/19/2005 01:50:00 13.5 1.4 17.2 10.7 13.4 1.4 17.9 10.3 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -15.5 0 -15 -15.6 02/19/2005 02:00:00 14 1.4 17.9 10.7 14.1 1.5 17.9 11.1 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -15.5 0.1 -15 -15.8 02/19/2005 02:10:00 15.8 1.5 19.5 11.8 15.8 1.4 19.1 11.8 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -15.5 0 -15 -15.6 02/19/2005 02:20:00 15.5 1.2 18.7 13 15.6 1.2 18.7 13 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -15.5 0.1 -15 -15.6 02/19/2005 02:30:00 16.1 1.8 21 11.8 16.1 1.7 19.9 11.8 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -15.5 0.1 -15 -15.8 02/19/2005 02:40:00 16.4 1.5 21 13.3 16.4 1.4 21 13.3 0.4 0 0.4 0.4 31 0 31 305 61 0 60 0 -15.5 0.1 -15 -15.8 02/19/2005 02:50:00 15.3 1.5 21 10.7 15.4 1.4 19.5 11.5 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -15.6 0 -15.2 -15.8 02/19/2005 03:00:00 15.2 1.9 19.9 10.7 15.4 2 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 61 0 60 0 -15.4 0.1 -15 -15.6 02/19/2005 03:10:00 14.9 1.9 18.3 10.3 14.9 1.9 18.7 9.9 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -15.4 0.1 -15 -15.6 02/19/2005 03:20:00 14.7 1.7 20.2 10.7 14.8 1.6 19.9 10.7 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -15.4 0.1 -14.8 -15.6 02/19/2005 03:30:00 14.1 1.7 18.3 10.3 14 1.7 18.3 10.7 0.4 0 0.4 0.4 31 0 31 305 61 0 62 0 -15.2 0 -15 -15.4 02/19/2005 03:40:00 14.2 1.7 19.5 10.7 14.2 1.7 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -15.1 0 -14.8 -15.2 02/19/2005 03:50:00 14.1 1.4 17.6 9.9 14.1 1.4 17.6 10.7 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -15.1 0 -14.8 -15.2 02/19/2005 04:00:00 13.8 1.8 18.7 9.9 13.7 1.8 19.9 10.3 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -15 0.1 -14.6 -15 02/19/2005 04:10:00 15 1.7 20.2 11.1 15 1.7 19.9 9.9 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -15 0 -14.6 -15 02/19/2005 04:20:00 14.6 1.7 19.5 10.3 14.4 1.8 19.5 9.9 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.9 0.1 -14.4 -15 02/19/2005 04:30:00 14.6 1.8 18.3 10.7 14.5 1.8 19.9 9.9 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.9 0 -14.6 -15 02/19/2005 04:40:00 15.2 2 19.9 10.7 14.9 1.9 20.6 10.7 0.4 0 0.4 0.4 31 0 31 305 64 0 63 0 -14.9 0 -14.4 -15 02/19/2005 04:50:00 15.9 1.9 21 11.8 16 1.9 21.4 11.1 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.9 0 -14.6 -15 02/19/2005 05:00:00 16.1 1.8 20.6 12.2 16 1.8 21 11.8 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.8 0 -14.6 -15 02/19/2005 05:10:00 15.8 1.7 19.5 11.5 15.9 1.7 19.9 11.8 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.8 0 -14.6 -15 02/19/2005 05:20:00 15.7 1.8 21.4 11.1 15.7 1.7 21 11.8 0.4 0 0.4 0.4 31 0 31 305 64 0 65 0 -14.8 0 -14.6 -15 02/19/2005 05:30:00 15.2 1.7 19.9 11.5 15.2 1.6 19.9 11.8 0.4 0 0.4 0.4 31 0 31 305 64 0 65 0 -14.8 0 -14.6 -15 02/19/2005 05:40:00 14.4 1.5 18.7 10.7 14.4 1.6 18.7 10.7 0.4 0 0.4 0.4 31 0 31 305 64 0 65 0 -14.8 0 -14.4 -15 02/19/2005 05:50:00 14 1.5 19.1 9.9 13.9 1.5 17.9 9.9 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.9 0.1 -14.4 -15 02/19/2005 06:00:00 13.7 1.6 18.7 10.7 13.5 1.7 17.9 10.3 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.8 0 -14.4 -15 02/19/2005 06:10:00 13.7 1.7 18.3 9.5 13.8 1.7 18.3 9.9 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.9 0.1 -14.6 -15 02/19/2005 06:20:00 14.9 1.7 19.5 10.3 15 1.7 19.9 9.9 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.9 0 -14.4 -15 02/19/2005 06:30:00 14.5 1.7 19.1 10.7 14.5 1.5 18.7 11.1 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.9 0 -14.4 -15 02/19/2005 06:40:00 14.3 1.6 19.1 10.3 14.1 1.5 18.7 10.7 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.8 0 -14.4 -15 02/19/2005 06:50:00 15.1 1.9 19.1 10.3 15 2 19.5 10.7 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.7 0 -14.3 -14.8 02/19/2005 07:00:00 14.7 1.4 18.7 10.3 14.7 1.5 18.7 10.7 0.4 0 0.4 0.4 31 0 31 305 64 0 65 0 -14.7 0 -14.3 -14.8 02/19/2005 07:10:00 15.7 1.6 20.2 12.2 15.6 1.5 19.5 12.2 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.6 0.1 -14.3 -14.6 02/19/2005 07:20:00 15 1.5 19.1 11.5 15.1 1.5 19.1 11.5 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.5 0.1 -14.1 -14.6 02/19/2005 07:30:00 14.9 1.6 18.3 11.8 14.6 1.5 18.7 11.8 0.4 0 0.4 0.4 31 0 31 305 65 0 66 0 -14.4 0 -14.1 -14.6 02/19/2005 07:40:00 14.1 1.7 18.3 9.5 14.1 1.8 18.7 9.9 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.3 0 -13.7 -14.4 02/19/2005 07:50:00 13.5 1.5 17.9 9.9 13.4 1.6 17.9 9.1 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.1 0 -13.7 -14.3 02/19/2005 08:00:00 12.6 1.8 18.3 9.1 12.5 1.8 18.3 8.8 0.4 0 0.4 0.4 31 0 31 305 67 0 67 0 -14 0.1 -13.5 -14.3 02/19/2005 08:10:00 13.2 1.9 18.3 9.1 13 1.9 17.9 8.4 0.4 0 0.4 0.4 31 0 31 305 67 0 68 0 -13.9 0 -13.5 -14.1 02/19/2005 08:20:00 13.3 1.5 17.2 9.5 13.3 1.5 17.2 9.1 0.4 0 0.4 0.4 31 0 31 305 68 0 68 0 -14 0.1 -13.5 -14.3 02/19/2005 08:30:00 13.8 1.8 18.7 9.9 13.7 1.8 19.1 9.5 0.4 0 0.4 0.4 31 0 31 305 68 0 68 0 -13.9 0 -13.5 -14.1 02/19/2005 08:40:00 13.6 1.9 19.5 9.5 13.6 1.9 18.7 9.5 0.4 0 0.4 0.4 31 0 31 305 68 0 68 0 -13.9 0 -13.5 -14.1 02/19/2005 08:50:00 14.7 2.1 20.2 9.9 14.5 2 19.9 9.9 0.4 0 0.4 0.4 31 0 31 305 69 0 69 0 -13.9 0 -13.7 -14.1 02/19/2005 09:00:00 14.9 2.7 21.8 8.8 14.8 2.6 20.6 8.4 0.4 0 0.4 0.4 31 0 31 305 69 0 69 0 -13.8 0 -13.3 -14.1 02/19/2005 09:10:00 14.4 1.9 19.1 9.9 14 1.9 19.1 10.3 0.4 0 0.4 0.4 31 0 31 305 69 0 69 0 -13.8 0 -13.7 -14.1 02/19/2005 09:20:00 16.3 1.9 20.6 11.8 16.3 1.9 21 12.2 0.4 0 0.4 0.4 31 0 31 305 69 0 69 0 -13.8 0 -13.7 -14.1 02/19/2005 09:30:00 15.1 1.7 20.2 11.5 15.1 1.6 19.9 11.5 0.4 0 0.4 0.4 31 0 31 305 70 0 70 0 -13.7 0 -13.3 -13.9 02/19/2005 09:40:00 15.1 2.2 21 9.9 15 2.1 20.6 9.9 0.4 0 0.4 0.4 31 0 31 305 70 0 70 0 -13.7 0 -13.5 -13.7 02/19/2005 09:50:00 16.4 1.9 22.1 11.5 16.2 1.9 22.1 11.5 0.4 0 0.4 0.4 31 0 31 305 70 0 70 0 -13.6 0 -13.3 -13.7 02/19/2005 10:00:00 15.9 2.2 21.8 11.1 15.9 2.2 21.8 11.1 0.4 0 0.4 0.4 31 0 31 305 70 0 71 0 -13.5 0.1 -13.1 -13.7 02/19/2005 10:10:00 15.2 2.6 21 9.1 15.1 2.4 21 9.9 0.4 0 0.4 0.4 31 0 31 305 71 0 71 0 -13.5 0.1 -13.1 -13.7 02/19/2005 10:20:00 14.5 2 20.2 10.3 14.7 2 21 10.7 0.4 0 0.4 0.4 31 0 31 305 71 0 71 0 -13.4 0.1 -13.1 -13.7 02/19/2005 10:30:00 14.8 2.2 20.6 9.5 14.8 2.2 21 8.8 0.4 0 0.4 0.4 31 0 31 305 71 0 72 0 -13.4 0 -13.1 -13.5 02/19/2005 10:40:00 13.9 1.7 18.7 9.5 14 1.7 18.7 9.9 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.4 0 -12.9 -13.5 02/19/2005 10:50:00 13.9 1.8 18.7 9.5 13.8 1.9 18.3 9.5 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.4 0 -12.9 -13.5 02/19/2005 11:00:00 13.6 1.7 17.6 10.3 13.7 1.7 18.3 9.9 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.4 0 -12.9 -13.5 02/19/2005 11:10:00 13.3 1 16.4 9.5 13.2 1.1 16.1 9.5 0.4 0 0.4 0.4 31 0 31 305 73 0 73 0 -13.3 0.1 -12.9 -13.5 02/19/2005 11:20:00 14 1.3 17.2 11.5 14.1 1.3 17.6 11.1 0.4 0 0.4 0.4 31 0 31 305 73 0 73 0 -13.3 0 -12.9 -13.3 02/19/2005 11:30:00 15.6 1.5 19.1 12.2 15.7 1.5 19.5 12.2 0.4 0 0.4 0.4 31 0 31 305 73 0 73 0 -13.3 0 -12.9 -13.5 02/19/2005 11:40:00 16.4 1.7 20.6 11.8 16.5 1.7 21.4 11.5 0.4 0 0.4 0.4 31 0 31 305 73 0 73 0 -13.2 0.1 -12.9 -13.3 02/19/2005 11:50:00 15.2 1.6 19.1 11.1 15.1 1.7 19.5 10.3 0.4 0 0.4 0.4 31 0 31 305 74 0 73 0 -13.2 0 -12.9 -13.3 02/19/2005 12:00:00 15.8 1.7 19.9 11.8 15.9 1.7 19.9 11.5 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -13.2 0 -12.9 -13.3 02/19/2005 12:10:00 15.2 1.4 19.1 12.2 15.1 1.5 19.5 11.5 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -13.2 0 -12.7 -13.3 02/19/2005 12:20:00 15.8 1.6 19.9 11.8 15.8 1.7 19.9 11.8 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -13.3 0 -12.9 -13.5 02/19/2005 12:30:00 15.2 1.5 19.5 11.5 15.3 1.5 20.2 11.5 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -13.2 0 -12.9 -13.3 02/19/2005 12:40:00 14.4 1.3 18.3 11.5 14.4 1.4 18.3 11.8 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -13.2 0 -12.9 -13.3 02/19/2005 12:50:00 16.7 1.3 20.6 13 16.7 1.3 20.2 13 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -13.3 0 -13.1 -13.5 02/19/2005 13:00:00 15.4 1.5 21.4 12.6 15.5 1.5 21.8 11.8 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -13.2 0 -12.9 -13.3 02/19/2005 13:10:00 15.4 1.1 18.3 12.2 15.4 1.1 18.3 12.6 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -13.1 0 -12.9 -13.3 02/19/2005 13:20:00 15.8 1.3 19.5 13 15.9 1.3 20.2 13 0.4 0 0.4 0.4 31 0 31 305 76 0 76 0 -13.1 0 -12.9 -13.1 02/19/2005 13:30:00 14.6 1.2 18.3 11.8 14.7 1.2 18.3 12.2 0.4 0 0.4 0.4 31 0 31 305 76 0 76 0 -13 0 -12.9 -13.1 02/19/2005 13:40:00 14.4 1 16.8 11.5 14.6 1 16.8 11.8 0.4 0 0.4 0.4 31 0 31 305 76 0 76 0 -13 0 -12.9 -13.1 02/19/2005 13:50:00 15.9 1.3 19.1 12.6 16 1.4 19.1 13 0.4 0 0.4 0.4 31 0 31 305 76 0 77 0 -13 0 -12.9 -13.1 02/19/2005 14:00:00 16.4 1 19.5 13.7 16.5 1.1 19.9 14.1 0.4 0 0.4 0.4 31 0 31 305 77 0 77 0 -13 0 -12.5 -13.1 02/19/2005 14:10:00 16.2 1.1 19.1 13 16.2 1.1 19.5 13 0.4 0 0.4 0.4 31 0 31 305 77 0 77 0 -12.9 0 -12.7 -12.9 02/19/2005 14:20:00 15.6 1.4 19.1 12.2 15.8 1.5 19.5 12.2 0.4 0 0.4 0.4 31 0 31 305 77 0 77 0 -12.9 0 -12.7 -13.1 02/19/2005 14:30:00 15.4 1.2 17.9 13 15.5 1.3 18.3 12.6 0.4 0 0.4 0.4 31 0 31 305 77 0 77 0 -12.9 0 -12.7 -12.9 02/19/2005 14:40:00 15.2 1.1 17.9 12.2 15.2 1.2 17.9 12.6 0.4 0 0.4 0.4 31 0 31 305 78 0 78 0 -12.8 0 -12.5 -12.9 02/19/2005 14:50:00 15.1 1.3 19.1 12.2 15.2 1.4 19.5 12.6 0.4 0 0.4 0.4 31 0 31 305 78 0 78 0 -12.6 0 -12.1 -12.9 02/19/2005 15:00:00 15.2 1.2 18.7 12.6 15.3 1.3 18.3 12.6 0.4 0 0.4 0.4 31 0 31 305 79 0 79 0 -12.5 0.1 -12.1 -12.7 02/19/2005 15:10:00 14.9 1 18.3 12.2 15 1.1 17.9 12.6 0.4 0 0.4 0.4 31 0 31 305 79 0 80 0 -12.3 0.1 -11.9 -12.5 02/19/2005 15:20:00 15.1 1.2 17.9 12.2 15.2 1.2 17.9 12.2 0.4 0 0.4 0.4 31 0 31 305 80 0 80 0 -12.3 0 -11.9 -12.5 02/19/2005 15:30:00 15.5 1.3 19.9 12.6 15.6 1.3 19.5 13 0.4 0 0.4 0.4 31 0 31 305 80 0 80 0 -12.3 0 -11.9 -12.5 02/19/2005 15:40:00 15.2 1.1 18.7 12.6 15.3 1.1 19.1 13 0.4 0 0.4 0.4 31 0 31 305 80 0 80 0 -12.3 0 -11.9 -12.5 02/19/2005 15:50:00 15.2 1 18.7 13 15.2 1.1 18.7 13 0.4 0 0.4 0.4 31 0 31 305 80 0 80 0 -12.2 0 -11.9 -12.5 02/19/2005 16:00:00 13.8 1.2 17.9 11.8 13.9 1.3 17.6 11.5 0.4 0 0.4 0.4 31 0 31 305 81 0 81 0 -12.1 0 -11.7 -12.3 02/19/2005 16:10:00 14.4 1.3 17.2 11.1 14.5 1.3 17.2 11.5 0.4 0 0.4 0.4 31 0 31 305 81 0 81 0 -12.2 0.2 -11.7 -12.5 02/19/2005 16:20:00 13.8 1.2 17.2 11.5 13.9 1.2 17.2 11.5 0.4 0 0.4 0.4 31 0 31 305 81 0 82 0 -12.2 0.1 -11.9 -12.5 02/19/2005 16:30:00 14.6 0.9 17.6 12.2 14.7 1 17.9 11.8 0.4 0 0.4 0.4 31 0 31 305 82 0 82 0 -12.4 0.1 -11.9 -12.5 02/19/2005 16:40:00 14.1 0.9 16.8 12.2 14.2 1 16.8 11.8 0.4 0 0.4 0.4 31 0 31 305 81 0 82 0 -12.5 0.1 -12.1 -12.7 02/19/2005 16:50:00 14.1 1 16.4 11.8 14.2 1 16.8 11.8 0.4 0 0.4 0.4 31 0 31 305 81 0 82 0 -12.6 0 -12.3 -12.7 02/19/2005 17:00:00 14.7 1.4 18.7 11.5 14.7 1.4 18.3 11.1 0.4 0 0.4 0.4 31 0 31 305 81 0 81 0 -12.6 0 -12.1 -12.9 02/19/2005 17:10:00 14.5 1.2 18.3 12.2 14.6 1.2 18.3 12.2 0.4 0 0.4 0.4 31 0 31 305 80 0 80 0 -12.8 0 -12.5 -12.9 02/19/2005 17:20:00 14.3 1 17.2 11.8 14.4 1.1 17.6 11.8 0.4 0 0.4 0.4 31 0 31 305 79 0 79 0 -12.8 0 -12.5 -12.9 02/19/2005 17:30:00 15.2 1 17.9 12.2 15.1 1 17.6 12.2 0.4 0 0.4 0.4 31 0 31 305 79 0 79 0 -12.8 0 -12.7 -12.9 02/19/2005 17:40:00 14.3 1 16.8 11.5 14.3 1 16.8 11.8 0.4 0 0.4 0.4 31 0 31 305 79 0 79 0 -12.7 0 -12.5 -12.9 02/19/2005 17:50:00 14.9 1.1 17.9 12.2 15.1 1.2 18.3 11.8 0.4 0 0.4 0.4 31 0 31 305 78 0 78 0 -12.6 0 -12.5 -12.9 02/19/2005 18:00:00 14 1 16.8 11.1 14.1 1.1 16.8 11.5 0.4 0 0.4 0.4 31 0 31 305 78 0 78 0 -12.6 0 -12.5 -12.9 02/19/2005 18:10:00 15.1 1.1 18.3 12.2 15.1 1.1 18.3 12.6 0.4 0 0.4 0.4 31 0 31 305 78 0 78 0 -12.6 0 -12.5 -12.9 02/19/2005 18:20:00 15.2 1 17.6 11.8 15.3 1.1 17.6 12.2 0.4 0 0.4 0.4 31 0 31 305 77 0 78 0 -12.6 0 -12.5 -12.7 02/19/2005 18:30:00 14.4 0.9 17.2 12.2 14.4 0.9 16.8 12.2 0.4 0 0.4 0.4 31 0 31 305 77 0 78 0 -12.7 0 -12.5 -12.9 02/19/2005 18:40:00 14.6 1.1 17.2 12.2 14.7 1.1 16.8 12.2 0.4 0 0.4 0.4 31 0 31 305 77 0 77 0 -12.8 0 -12.5 -12.9 02/19/2005 18:50:00 13.7 0.9 16.4 11.5 13.8 1 16.4 11.8 0.4 0 0.4 0.4 31 0 31 305 77 0 77 0 -12.7 0 -12.3 -12.9 02/19/2005 19:00:00 14.5 1 17.2 11.8 14.6 1 17.2 12.6 0.4 0 0.4 0.4 31 0 31 305 76 0 77 0 -12.9 0 -12.5 -12.9 02/19/2005 19:10:00 14.3 1.1 16.4 11.5 14.3 1.1 16.8 11.5 0.4 0 0.4 0.4 31 0 31 305 76 0 76 0 -12.9 0 -12.5 -12.9 02/19/2005 19:20:00 13.1 1 15.6 11.1 13 1 16.1 11.1 0.4 0 0.4 0.4 31 0 31 305 76 0 76 0 -12.9 0 -12.5 -13.1 02/19/2005 19:30:00 14.8 1.1 18.3 12.2 14.9 1.3 18.3 11.5 0.4 0 0.4 0.4 31 0 31 305 76 0 76 0 -12.8 0 -12.5 -12.9 02/19/2005 19:40:00 13.1 1.2 16.1 10.3 13.2 1.2 16.1 10.7 0.4 0 0.4 0.4 31 0 31 305 75 0 76 0 -12.8 0 -12.5 -12.9 02/19/2005 19:50:00 14.5 1.4 18.3 11.1 14.6 1.3 18.3 10.7 0.4 0 0.4 0.4 31 0 31 305 75 0 76 0 -12.7 0 -12.5 -12.9 02/19/2005 20:00:00 16.5 1.2 19.9 13 16.7 1.2 19.9 13.7 0.4 0 0.4 0.4 31 0 31 305 75 0 76 0 -12.8 0 -12.5 -12.9 02/19/2005 20:10:00 15.1 1.2 18.3 12.2 15.3 1.3 18.3 12.2 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -12.8 0 -12.5 -12.9 02/19/2005 20:20:00 14.9 1.4 19.1 12.2 14.9 1.5 19.5 11.8 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -12.8 0 -12.5 -12.9 02/19/2005 20:30:00 15.8 1.5 21.8 12.2 15.8 1.5 21 12.6 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -12.9 0.1 -12.5 -13.1 02/19/2005 20:40:00 14.8 1.4 18.3 11.1 14.8 1.5 18.7 11.5 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -12.9 0 -12.5 -13.1 02/19/2005 20:50:00 15.4 1.3 19.1 12.6 15.3 1.3 18.7 12.6 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -12.9 0 -12.5 -13.1 02/19/2005 21:00:00 14.7 1.3 17.9 11.5 14.8 1.4 18.7 11.5 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -12.9 0.1 -12.5 -13.1 02/19/2005 21:10:00 13.7 1.3 17.2 10.3 13.7 1.3 17.6 9.9 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -12.8 0 -12.5 -12.9 02/19/2005 21:20:00 13.7 1.3 17.2 10.7 13.8 1.3 17.2 11.1 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -12.9 0.1 -12.5 -12.9 02/19/2005 21:30:00 14 1.2 17.6 11.5 14 1.2 17.6 11.8 0.4 0 0.4 0.4 31 0 31 305 75 0 74 0 -12.8 0 -12.5 -12.9 02/19/2005 21:40:00 12.7 1.2 15.3 9.5 12.6 1.2 15.3 9.5 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -12.8 0 -12.5 -12.9 02/19/2005 21:50:00 12.7 1.2 16.4 9.5 12.7 1.2 16.8 10.3 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -12.8 0 -12.5 -12.9 02/19/2005 22:00:00 13.9 1.3 17.2 10.3 13.7 1.3 17.2 9.9 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -12.8 0 -12.5 -12.9 02/19/2005 22:10:00 11.8 1.4 16.1 9.1 11.7 1.5 16.4 8.8 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -12.8 0 -12.5 -12.9 02/19/2005 22:20:00 15.1 1.2 17.9 11.8 14.9 1.2 17.9 11.1 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -12.9 0 -12.7 -12.9 02/19/2005 22:30:00 13.5 1.1 16.8 11.1 13.4 1.1 16.4 11.1 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -12.9 0 -12.5 -12.9 02/19/2005 22:40:00 14.4 1.4 17.9 11.8 14.2 1.4 17.9 10.3 0.4 0 0.4 0.4 31 0 31 305 75 0 75 0 -12.9 0 -12.7 -12.9 02/19/2005 22:50:00 13.6 1.1 17.2 11.1 13.6 1.1 16.4 11.1 0.4 0 0.4 0.4 31 0 31 305 75 0 74 0 -12.9 0 -12.7 -12.9 02/19/2005 23:00:00 13.4 1.4 16.8 10.3 13.4 1.5 17.2 10.3 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -12.9 0 -12.5 -13.1 02/19/2005 23:10:00 15 1.4 19.1 11.8 15.1 1.4 18.3 11.8 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -13 0 -12.9 -13.1 02/19/2005 23:20:00 15.1 1.3 18.7 11.8 15.2 1.3 18.7 12.2 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -13 0 -12.9 -13.1 02/19/2005 23:30:00 15.1 1.4 18.3 11.8 15 1.3 18.3 11.8 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -13 0 -12.9 -13.1 02/19/2005 23:40:00 15.7 1.3 19.1 13 15.8 1.4 19.5 12.6 0.4 0 0.4 0.4 31 0 31 305 74 0 74 0 -13.1 0 -12.9 -13.3 02/19/2005 23:50:00 16.1 1.6 20.2 11.5 15.9 1.7 20.2 11.5 0.4 0 0.4 0.4 31 0 31 305 74 0 73 0 -13.1 0 -12.9 -13.3 02/20/2005 00:00:00 14.9 1.3 18.7 11.8 14.8 1.2 18.3 11.8 0.4 0 0.4 0.4 31 0 31 305 73 0 73 0 -13.1 0 -13.1 -13.3 02/20/2005 00:10:00 16.1 1.1 19.1 13.3 16 1.2 19.9 13.3 0.4 0 0.4 0.4 31 0 31 305 73 0 73 0 -13.1 0 -13.1 -13.3 02/20/2005 00:20:00 16.4 1.9 21 12.6 16.3 1.9 21 12.2 0.4 0 0.4 0.4 31 0 31 305 73 0 73 0 -13.2 0 -13.1 -13.3 02/20/2005 00:30:00 15.3 1.3 19.5 12.6 15.2 1.3 19.5 12.6 0.4 0 0.4 0.4 31 0 31 305 73 0 73 0 -13.1 0 -13.1 -13.3 02/20/2005 00:40:00 15.1 1.3 18.7 12.2 15 1.3 18.7 12.2 0.4 0 0.4 0.4 31 0 31 305 73 0 73 0 -13.2 0 -13.1 -13.3 02/20/2005 00:50:00 14.7 1.5 18.7 11.5 14.5 1.4 18.7 11.1 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.2 0 -13.1 -13.3 02/20/2005 01:00:00 13.4 1.5 17.2 9.9 13.4 1.5 16.8 9.9 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.1 0 -13.1 -13.3 02/20/2005 01:10:00 14.4 1.5 17.9 10.7 14.4 1.5 18.3 10.7 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.2 0 -13.1 -13.3 02/20/2005 01:20:00 13 1.2 16.1 9.9 12.9 1.2 16.8 10.7 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.1 0 -13.1 -13.3 02/20/2005 01:30:00 13.9 2.5 18.7 8.8 13.8 2.4 18.7 9.1 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.2 0 -13.1 -13.3 02/20/2005 01:40:00 13.1 1.3 16.4 9.9 13.2 1.3 17.2 8.8 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.2 0 -13.1 -13.5 02/20/2005 01:50:00 13.5 1.2 16.1 10.7 13.5 1.2 16.4 10.3 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.4 0 -13.3 -13.5 02/20/2005 02:00:00 12.6 1.2 15.6 9.5 12.7 1.2 15.6 9.9 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.4 0 -13.3 -13.5 02/20/2005 02:10:00 12.2 1.6 16.8 9.1 12.1 1.6 17.2 9.1 0.4 0 0.4 0.4 31 0 31 305 72 0 72 0 -13.4 0 -12.9 -13.5 02/20/2005 02:20:00 12.3 1.3 16.1 9.1 12 1.3 16.1 9.1 0.4 0 0.4 0.4 31 0 31 305 71 0 71 0 -13.4 0.1 -12.9 -13.7 02/20/2005 02:30:00 13.6 1.5 17.2 10.3 13.5 1.3 16.8 10.3 0.4 0 0.4 0.4 31 0 31 305 71 0 71 0 -13.5 0.1 -13.1 -13.7 02/20/2005 02:40:00 13.1 1.4 16.8 9.9 12.8 1.4 16.8 9.5 0.4 0 0.4 0.4 31 0 31 305 71 0 71 0 -13.6 0 -13.3 -13.7 02/20/2005 02:50:00 12.6 1.1 14.9 9.5 12.5 1.1 15.3 9.9 0.4 0 0.4 0.4 31 0 31 305 70 0 71 0 -13.8 0.1 -13.3 -13.9 02/20/2005 03:00:00 11.8 1.3 15.3 8.8 11.7 1.3 14.9 8.8 0.4 0 0.4 0.4 31 0 31 305 70 0 70 0 -13.7 0 -13.3 -14.1 02/20/2005 03:10:00 12.6 1.3 15.6 9.1 12.6 1.2 15.6 9.5 0.4 0 0.4 0.4 31 0 31 305 69 0 69 0 -13.9 0.1 -13.7 -14.3 02/20/2005 03:20:00 13.1 1.5 16.4 9.5 12.9 1.5 16.8 9.5 0.4 0 0.4 0.4 31 0 31 305 69 0 69 0 -13.9 0.1 -13.7 -14.3 02/20/2005 03:30:00 13 1.7 16.8 8 12.7 1.7 16.8 8 0.4 0 0.4 0.4 31 0 31 305 68 0 68 0 -14 0.1 -13.7 -14.3 02/20/2005 03:40:00 12.6 1.5 15.6 9.1 12.3 1.4 15.3 8.8 0.4 0 0.4 0.4 31 0 31 305 68 0 68 0 -13.9 0.1 -13.5 -14.3 02/20/2005 03:50:00 12.3 1.3 15.6 9.1 12.1 1.3 15.3 9.1 0.4 0 0.4 0.4 31 0 31 305 68 0 68 0 -13.9 0.1 -13.7 -14.3 02/20/2005 04:00:00 13.6 2.1 20.2 9.5 13.4 2 19.9 9.5 0.4 0 0.4 0.4 31 0 31 305 68 0 67 0 -13.9 0 -13.5 -14.1 02/20/2005 04:10:00 14.3 2.2 19.9 9.1 14 2.1 19.9 9.1 0.4 0 0.4 0.4 31 0 31 305 67 0 68 0 -13.8 0 -13.5 -14.1 02/20/2005 04:20:00 15 2.1 20.6 9.5 14.9 2 20.2 9.9 0.4 0 0.4 0.4 31 0 31 305 67 0 67 0 -13.8 0 -13.5 -14.1 02/20/2005 04:30:00 14.1 2.4 20.6 9.9 13.9 2.3 20.2 8.4 0.4 0 0.4 0.4 31 0 31 305 67 0 67 0 -13.8 0 -13.5 -14.1 02/20/2005 04:40:00 15.3 1.9 21 10.7 15.1 1.8 20.6 10.3 0.4 0 0.4 0.4 31 0 31 305 67 0 67 0 -13.9 0 -13.7 -14.3 02/20/2005 04:50:00 15.2 2.2 20.6 10.7 15 2.1 21 10.7 0.4 0 0.4 0.4 31 0 31 305 67 0 67 0 -14.1 0.1 -13.7 -14.3 02/20/2005 05:00:00 15.2 1.9 20.6 11.1 14.9 1.8 20.6 10.3 0.4 0 0.4 0.4 31 0 31 305 67 0 67 0 -14.1 0 -13.9 -14.3 02/20/2005 05:10:00 14.6 1.7 19.5 10.3 14.5 2 19.5 10.3 0.4 0 0.4 0.4 31 0 31 305 67 0 67 0 -14.1 0 -13.9 -14.3 02/20/2005 05:20:00 14 2.1 19.1 9.1 13.8 2.1 18.7 9.5 0.4 0 0.4 0.4 31 0 31 305 67 0 67 0 -14.1 0 -13.9 -14.3 02/20/2005 05:30:00 14.8 2 22.6 10.7 14.6 2.1 20.2 9.5 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.1 0 -13.9 -14.3 02/20/2005 05:40:00 16.1 1.6 19.5 11.8 16.1 1.6 19.9 11.8 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.2 0 -14.1 -14.3 02/20/2005 05:50:00 14 1.7 19.5 9.1 14 1.8 19.1 9.1 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.2 0 -14.1 -14.3 02/20/2005 06:00:00 15.5 2.2 21.8 10.7 15.5 2.2 21.4 10.7 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.2 0 -14.1 -14.3 02/20/2005 06:10:00 16.3 1.9 21 11.1 15.9 1.9 20.6 11.1 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.2 0 -14.1 -14.3 02/20/2005 06:20:00 15.8 1.7 21.4 12.2 15.6 1.5 20.2 11.8 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.2 0 -14.1 -14.3 02/20/2005 06:30:00 15.4 2.2 21.8 10.7 15.2 2.1 21.8 11.1 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.2 0 -14.1 -14.3 02/20/2005 06:40:00 16.2 1.7 20.2 11.8 15.9 1.7 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.3 0 -14.1 -14.4 02/20/2005 06:50:00 17.1 2 21.8 11.1 16.9 2 22.1 11.1 0.4 0 0.4 0.4 31 0 31 305 65 0 66 0 -14.3 0.1 -13.9 -14.4 02/20/2005 07:00:00 16.6 2.4 22.6 9.5 16.1 2.3 21.4 10.3 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.3 0 -14.1 -14.6 02/20/2005 07:10:00 18.1 2.1 24 13.3 17.7 2.1 24 12.2 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.4 0 -14.1 -14.6 02/20/2005 07:20:00 17 2.1 22.1 12.6 16.6 2 21.8 11.1 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.4 0 -13.9 -14.6 02/20/2005 07:30:00 17.5 2.3 22.6 12.6 17.1 2.3 22.1 11.5 0.4 0 0.4 0.4 31 0 31 305 64 0 65 0 -14.4 0 -14.1 -14.6 02/20/2005 07:40:00 17.4 2 21.8 11.8 17.1 2 21.8 12.2 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.5 0.1 -14.3 -14.6 02/20/2005 07:50:00 16.9 1.7 21.4 12.6 16.7 1.7 21.4 12.2 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.6 0.1 -14.3 -14.6 02/20/2005 08:00:00 17.7 2.5 24 10.7 17.2 2.3 23.7 10.7 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.7 0 -14.4 -14.8 02/20/2005 08:10:00 17.4 2.5 23.3 11.5 17 2.4 22.9 11.1 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.7 0 -14.3 -14.8 02/20/2005 08:20:00 18 1.9 22.6 13.7 17.6 1.8 22.9 13.7 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.7 0 -14.3 -14.8 02/20/2005 08:30:00 17 2.3 22.6 11.1 16.5 2.2 22.1 11.5 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.7 0 -14.3 -14.8 02/20/2005 08:40:00 17.2 1.9 21.4 12.6 16.9 1.8 21.4 11.1 0.4 0 0.4 0.4 31 0 31 305 62 0 63 0 -14.7 0 -14.4 -14.8 02/20/2005 08:50:00 17.9 2.4 24.4 12.6 17.6 2.2 24 13 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.4 -14.8 02/20/2005 09:00:00 17.8 2.5 23.7 12.6 17.5 2.5 23.3 11.8 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.4 -15 02/20/2005 09:10:00 17 2.6 22.6 11.1 16.7 2.5 22.9 11.5 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.6 -14.8 02/20/2005 09:20:00 17.6 2 22.6 12.2 17.4 1.8 22.1 12.6 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.6 -14.8 02/20/2005 09:30:00 17.9 1.8 22.6 13.3 17.7 1.7 21.8 12.6 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.6 -14.8 02/20/2005 09:40:00 16.9 1.7 21 12.6 16.7 1.7 20.6 12.6 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.6 -14.6 02/20/2005 09:50:00 18 2 22.9 13 17.6 1.9 22.1 11.5 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.6 -14.8 02/20/2005 10:00:00 17.5 1.8 21.8 13 17.3 1.8 21.4 12.6 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.6 0 -14.4 -14.6 02/20/2005 10:10:00 16.7 1.7 21.4 12.6 16.5 1.7 20.6 11.5 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.6 -14.6 02/20/2005 10:20:00 16.2 1.9 20.6 11.8 16 1.9 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.4 -14.6 02/20/2005 10:30:00 17.2 1.9 21.8 13 16.8 1.8 21 13 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.4 -14.8 02/20/2005 10:40:00 17.2 2.1 22.1 11.8 16.8 2 22.1 11.1 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.6 -14.6 02/20/2005 10:50:00 16.4 1.9 21.4 12.2 16.1 1.8 20.6 12.2 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.6 -14.6 02/20/2005 11:00:00 18 2.3 23.3 13 17.8 2.3 23.3 12.6 0.4 0 0.4 0.4 31 0 31 305 62 0 63 0 -14.7 0 -14.4 -14.8 02/20/2005 11:10:00 17.5 2 22.9 12.6 17.2 1.9 21.4 12.2 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.7 0 -14.4 -14.6 02/20/2005 11:20:00 17.2 2.4 22.9 11.8 16.9 2.4 22.6 11.5 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.6 0.1 -14.3 -14.6 02/20/2005 11:30:00 18 1.6 22.6 13.7 17.8 1.5 21.8 13.3 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.7 0.1 -14.3 -14.6 02/20/2005 11:40:00 17.3 1.9 23.3 12.6 17 1.7 22.1 12.6 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.6 0.1 -14.3 -14.8 02/20/2005 11:50:00 17.3 2.4 24.4 12.2 17.1 2.3 22.9 12.6 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.6 0.1 -14.3 -14.6 02/20/2005 12:00:00 17.5 1.7 22.6 13.3 17.3 1.8 23.3 12.6 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.6 0.1 -14.3 -14.6 02/20/2005 12:10:00 17.7 2.1 22.9 10.7 17.3 2 22.6 11.8 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.5 0.1 -14.3 -14.6 02/20/2005 12:20:00 18.2 2.2 23.7 13.3 17.9 2.1 22.9 13 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.5 0.1 -14.3 -14.6 02/20/2005 12:30:00 18.4 1.8 23.3 14.1 18.1 1.8 22.6 14.1 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.5 0.1 -14.3 -14.6 02/20/2005 12:40:00 18 1.7 22.6 13.7 17.7 1.7 21.8 12.6 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.6 0.1 -14.3 -14.6 02/20/2005 12:50:00 17.7 1.7 23.7 13.7 17.4 1.7 22.1 13 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.6 0.1 -14.3 -14.6 02/20/2005 13:00:00 17.9 1.8 23.3 13.7 17.4 1.8 22.6 13.3 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.7 0 -14.3 -14.6 02/20/2005 13:10:00 17.7 1.9 22.9 13.3 17.4 2 23.7 11.8 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.7 0 -14.3 -14.6 02/20/2005 13:20:00 18.6 2.1 23.7 13 18.3 2 23.3 13.7 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.7 0.1 -14.3 -14.8 02/20/2005 13:30:00 17.4 2.2 22.9 12.6 17.2 2.1 22.6 12.6 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.6 0.1 -14.3 -14.6 02/20/2005 13:40:00 19.3 2.2 24 13.3 19 2.3 24 12.6 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.7 0 -14.4 -14.6 02/20/2005 13:50:00 19.3 2.5 25.2 14.1 19.1 2.5 25.2 13.3 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.5 0 -14.3 -14.6 02/20/2005 14:00:00 18.2 2.1 23.3 12.6 18 2.1 22.9 12.6 0.4 0 0.4 0.4 31 0 31 305 66 0 65 0 -14.5 0 -14.3 -14.6 02/20/2005 14:10:00 18.5 2.4 24.4 12.6 18.2 2.4 24 12.2 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.5 0 -14.3 -14.6 02/20/2005 14:20:00 18.9 2.1 24.8 12.2 18.6 2.1 24 11.8 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.6 0 -14.4 -14.6 02/20/2005 14:30:00 18.6 2.3 22.6 12.6 18.2 2.2 22.9 12.6 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.5 0 -14.4 -14.6 02/20/2005 14:40:00 20.1 2 25.2 14.9 19.8 2 25.6 14.9 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.6 0 -14.4 -14.6 02/20/2005 14:50:00 17.9 2.1 23.7 12.6 17.9 2 23.3 13 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.5 0 -14.3 -14.6 02/20/2005 15:00:00 18.3 2.1 22.9 12.6 17.9 2 22.6 12.6 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.6 0 -14.4 -14.6 02/20/2005 15:10:00 18.6 2 23.7 14.1 18.2 1.8 23.3 13.3 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.6 0 -14.4 -14.6 02/20/2005 15:20:00 18.8 1.8 23.7 14.5 18.5 1.9 23.3 13.7 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.6 0 -14.4 -14.6 02/20/2005 15:30:00 17.8 2.3 23.3 12.2 17.4 2.3 23.3 12.6 0.4 0 0.4 0.4 31 0 31 305 65 0 66 0 -14.6 0 -14.4 -14.6 02/20/2005 15:40:00 17.6 2.1 23.3 11.8 17.3 2.1 23.3 13 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.5 0 -14.3 -14.6 02/20/2005 15:50:00 17.4 2 22.9 13 16.9 2.1 21.8 12.6 0.4 0 0.4 0.4 31 0 31 305 65 0 66 0 -14.5 0.1 -14.1 -14.6 02/20/2005 16:00:00 18.1 2.3 22.9 12.2 17.6 2.2 22.1 12.6 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.4 0 -14.1 -14.6 02/20/2005 16:10:00 17.6 2.3 22.9 11.8 17.4 2.1 21.8 12.6 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.4 0.1 -14.1 -14.6 02/20/2005 16:20:00 19.2 2.5 25.2 13.3 18.8 2.4 24.8 12.6 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.4 0 -14.1 -14.6 02/20/2005 16:30:00 20 2.3 24.8 13 19.5 2.4 24.8 12.2 0.4 0 0.4 0.4 31 0 31 305 65 0 66 0 -14.4 0.1 -14.1 -14.6 02/20/2005 16:40:00 19.3 2.1 24.8 14.1 18.8 2.2 23.7 13.3 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.4 0 -14.1 -14.6 02/20/2005 16:50:00 19.6 2.2 24.4 13 18.9 2.2 24 12.2 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.4 0.1 -14.1 -14.6 02/20/2005 17:00:00 19.3 2.1 24 14.5 18.9 2.2 23.7 14.1 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.5 0.1 -14.1 -14.6 02/20/2005 17:10:00 19.6 1.8 24.4 14.9 19.2 1.8 24 13.3 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.4 0.1 -14.1 -14.6 02/20/2005 17:20:00 18.7 2 22.9 13.7 18.3 2 23.7 13 0.4 0 0.4 0.4 31 0 31 305 65 0 65 0 -14.5 0.1 -14.3 -14.6 02/20/2005 17:30:00 16.8 1.8 21.8 13 16.4 1.7 20.6 11.5 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.5 0.1 -14.3 -14.6 02/20/2005 17:40:00 18.2 2 23.7 14.1 17.7 2.1 22.9 13 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.4 0 -14.1 -14.6 02/20/2005 17:50:00 18.1 2.2 24.8 12.6 17.6 2.1 24.4 12.2 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.5 0 -14.3 -14.6 02/20/2005 18:00:00 18.3 2 23.7 13.3 17.9 2 22.9 13 0.4 0 0.4 0.4 31 0 31 305 64 0 64 0 -14.5 0.1 -14.3 -14.6 02/20/2005 18:10:00 18.2 2.1 25.2 13.3 17.7 2 24 13.7 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.5 0 -14.3 -14.6 02/20/2005 18:20:00 18.5 2.9 25.2 12.2 18.2 2.9 24.4 12.2 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.5 0 -14.3 -14.6 02/20/2005 18:30:00 17.9 2.4 24.4 13 17.4 2.3 22.9 12.2 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.5 0 -14.3 -14.6 02/20/2005 18:40:00 17.3 2.1 23.3 12.6 17 2.1 24 11.8 0.4 0 0.4 0.4 31 0 31 305 62 0 63 0 -14.6 0 -14.4 -14.6 02/20/2005 18:50:00 17.1 2 21.4 12.2 16.6 1.8 21.8 12.2 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.4 -14.8 02/20/2005 19:00:00 17.7 2.2 22.9 13 17.3 2.1 22.1 13.3 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.7 0 -14.4 -14.6 02/20/2005 19:10:00 16.9 2 23.3 12.6 16.5 2 21.8 12.2 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -14.7 0 -14.6 -14.8 02/20/2005 19:20:00 17.1 1.8 20.6 11.8 16.7 2 21 11.1 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -14.7 0 -14.6 -15 02/20/2005 19:30:00 17.1 2.1 21.4 11.8 16.7 2.1 21.4 12.2 0.4 0 0.4 0.4 31 0 31 305 60 0 61 0 -14.7 0 -14.6 -14.8 02/20/2005 19:40:00 16.6 2.1 22.6 12.2 16.4 2.2 21.8 11.5 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.7 0 -14.6 -14.8 02/20/2005 19:50:00 17.5 1.5 21.4 13.3 17.1 1.6 21.8 12.6 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.7 0 -14.6 -14.8 02/20/2005 20:00:00 16.6 1.7 20.6 12.6 16.2 1.7 20.6 11.8 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.7 0 -14.6 -14.8 02/20/2005 20:10:00 17.6 1.7 22.1 13.3 17.1 1.7 22.1 12.2 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.7 0 -14.6 -14.8 02/20/2005 20:20:00 16.9 1.7 21 13 16.5 1.7 21.4 12.6 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.7 0 -14.3 -14.6 02/20/2005 20:30:00 16.8 2 21.8 12.2 16.2 1.8 21.4 11.8 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.6 0.1 -14.3 -14.6 02/20/2005 20:40:00 16.8 1.9 22.9 12.6 16.4 2 22.1 11.8 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.5 0.1 -14.3 -14.6 02/20/2005 20:50:00 17.9 2.1 22.6 12.6 17.5 2.1 21.8 12.2 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.5 0.1 -14.3 -14.6 02/20/2005 21:00:00 18.2 2 23.7 13.3 17.6 1.9 23.7 12.6 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.6 0.1 -14.3 -14.6 02/20/2005 21:10:00 17.5 2 22.9 12.6 17.1 2 22.6 11.8 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.6 0.1 -14.3 -14.6 02/20/2005 21:20:00 16.6 2.2 21 11.5 16.1 2.1 20.6 11.1 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.5 0.1 -14.3 -14.6 02/20/2005 21:30:00 16.2 1.7 21 12.2 15.8 1.9 20.6 11.1 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.4 0 -13.9 -14.6 02/20/2005 21:40:00 17.2 1.8 22.1 12.2 16.8 1.9 22.1 12.2 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.4 0 -14.1 -14.6 02/20/2005 21:50:00 17.5 2.1 24.4 13.3 17.1 2.1 24 13 0.4 0 0.4 0.4 31 0 31 305 61 0 60 0 -14.4 0.1 -13.9 -14.6 02/20/2005 22:00:00 16.5 1.9 21.8 11.5 16.2 2 21 11.8 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -14.5 0.1 -14.3 -14.6 02/20/2005 22:10:00 17.4 2 22.6 12.2 16.9 2.1 22.1 12.6 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -14.6 0.1 -14.3 -14.6 02/20/2005 22:20:00 18.4 1.8 22.9 13.7 18 1.7 22.9 13.7 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.7 0 -14.3 -14.6 02/20/2005 22:30:00 18.5 1.8 22.6 13.7 18.1 2 23.3 13 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.6 0 -14.3 -14.6 02/20/2005 22:40:00 18 2.2 23.3 12.6 17.6 2.1 22.9 11.8 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.7 0 -14.3 -14.8 02/20/2005 22:50:00 17.5 1.8 22.6 13 17 1.7 21.4 13 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.7 0 -14.6 -14.8 02/20/2005 23:00:00 17.4 2.2 22.1 12.2 17 2.1 21.4 12.2 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.8 0 -14.6 -15 02/20/2005 23:10:00 17.5 1.9 22.9 13.3 17 1.9 22.6 12.2 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.8 0 -14.6 -15 02/20/2005 23:20:00 17.2 1.7 21.4 13 16.8 1.7 21 13 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.8 0 -14.6 -15 02/20/2005 23:30:00 16.6 2.1 21.4 11.8 16.1 2.2 21 11.8 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.7 0 -14.4 -14.8 02/20/2005 23:40:00 17.7 2.2 24.4 13 17.4 2.3 23.7 13 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.7 0 -14.4 -14.8 02/20/2005 23:50:00 17.2 2.2 22.6 10.7 16.8 2.2 21.8 10.3 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.6 0 -14.3 -14.6 02/21/2005 00:00:00 16.2 2.1 22.9 11.8 15.8 2.1 23.3 11.1 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.7 0 -14.3 -14.6 02/21/2005 00:10:00 16.4 2.4 22.6 12.2 16.1 2.4 22.9 11.5 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.6 0.1 -14.3 -14.6 02/21/2005 00:20:00 15.1 1.6 20.2 11.8 14.6 1.8 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.6 0.1 -14.3 -14.6 02/21/2005 00:30:00 16.7 2.6 22.9 11.5 16.4 2.5 21.8 11.5 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.6 0.1 -14.3 -14.6 02/21/2005 00:40:00 17.6 2.5 23.7 13.7 17.3 2.5 23.7 12.6 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.6 0.1 -14.3 -14.6 02/21/2005 00:50:00 17.8 1.7 22.6 13.7 17.5 1.7 22.1 13.7 0.4 0 0.4 0.4 31 1 31 305 59 0 59 0 -14.7 0 -14.3 -14.6 02/21/2005 01:00:00 16.9 1.9 21.8 12.2 16.6 1.9 22.1 12.6 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.6 0.1 -14.3 -14.6 02/21/2005 01:10:00 17.6 2 23.3 12.2 17.3 1.9 22.6 11.8 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.6 0.1 -14.3 -14.6 02/21/2005 01:20:00 17.5 2.3 23.3 11.8 17.2 2.3 22.6 12.2 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.6 0.1 -14.3 -14.8 02/21/2005 01:30:00 17.6 2 22.6 13 17.4 2 22.6 13 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.7 0 -14.3 -14.6 02/21/2005 01:40:00 17 1.8 21.8 12.6 16.7 1.8 21.8 13 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.7 0.1 -14.3 -14.8 02/21/2005 01:50:00 17 2 21.8 13 16.5 2 21.4 12.6 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.7 0 -14.3 -14.8 02/21/2005 02:00:00 17.2 1.6 21 13 16.8 1.7 21 11.8 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -14.6 0.1 -14.3 -14.6 02/21/2005 02:10:00 16.6 2.1 22.6 11.8 16 2 21.4 11.5 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -14.6 0.1 -14.3 -14.6 02/21/2005 02:20:00 16.2 2.4 22.1 11.5 15.7 2.4 21.8 11.1 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -14.6 0.1 -14.3 -14.6 02/21/2005 02:30:00 16.4 1.5 19.5 13 16 1.5 19.5 12.2 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -14.6 0.1 -14.3 -14.8 02/21/2005 02:40:00 16.1 1.9 21.8 11.5 15.7 2 21.8 11.1 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -14.6 0.1 -14.3 -14.6 02/21/2005 02:50:00 17.1 2.2 22.9 12.6 16.9 2.1 22.1 12.6 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -14.6 0.1 -14.3 -14.6 02/21/2005 03:00:00 15.7 1.5 19.5 10.3 15.2 1.5 19.1 11.1 0.4 0 0.4 0.4 31 0 31 305 58 0 59 0 -14.5 0.1 -14.3 -14.6 02/21/2005 03:10:00 14.9 1.6 19.1 10.7 14.5 1.5 19.5 10.7 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.5 0.1 -14.3 -14.6 02/21/2005 03:20:00 16.2 2 21.8 11.5 15.8 2.1 21.4 10.7 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.4 0 -14.1 -14.6 02/21/2005 03:30:00 15.6 1.7 20.2 10.7 15.1 1.9 19.5 10.7 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.4 0 -14.1 -14.6 02/21/2005 03:40:00 16.4 2 21 11.8 15.8 2 21 11.1 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.3 0 -13.9 -14.4 02/21/2005 03:50:00 16 1.9 21 11.8 15.6 1.9 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.2 0 -13.9 -14.4 02/21/2005 04:00:00 16 2.2 23.7 10.7 15.7 2.2 23.3 10.7 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.2 0 -13.7 -14.3 02/21/2005 04:10:00 15.8 1.6 19.9 12.2 15.6 1.6 19.9 11.8 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.2 0 -13.7 -14.3 02/21/2005 04:20:00 17 1.5 20.6 13.3 16.5 1.5 20.2 12.6 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -14.2 0 -13.7 -14.4 02/21/2005 04:30:00 16.4 2.3 22.1 10.7 15.9 2.3 22.1 11.5 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -14.2 0 -13.9 -14.4 02/21/2005 04:40:00 17 1.5 21 13 16.7 1.6 20.6 13 0.4 0 0.4 0.4 31 0 31 305 61 0 60 0 -14.2 0 -13.9 -14.4 02/21/2005 04:50:00 16.9 1.9 22.6 11.1 16.6 1.9 22.6 11.1 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -14.2 0 -13.7 -14.4 02/21/2005 05:00:00 16.1 1.8 21.8 11.8 15.7 1.9 20.6 11.5 0.4 0 0.4 0.4 31 0 31 305 61 0 60 0 -14.2 0 -13.7 -14.3 02/21/2005 05:10:00 15.2 2.1 21.4 11.1 14.7 2.2 21 10.3 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -14.2 0 -13.7 -14.3 02/21/2005 05:20:00 16.8 1.8 20.6 11.8 16.2 1.8 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -14.3 0 -13.9 -14.4 02/21/2005 05:30:00 17.5 1.7 21.8 13 17.1 1.7 22.1 12.6 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.3 0 -13.9 -14.4 02/21/2005 05:40:00 17.2 1.9 21.8 12.2 16.9 1.8 22.1 12.6 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.2 0 -13.9 -14.4 02/21/2005 05:50:00 17.1 1.6 20.6 13.3 16.7 1.7 20.6 12.6 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.3 0 -13.9 -14.4 02/21/2005 06:00:00 16 1.7 21 11.8 15.7 1.7 21 11.5 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.3 0.1 -13.9 -14.4 02/21/2005 06:10:00 17.4 1.7 21.4 11.8 16.9 1.7 21.4 11.1 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -14.3 0 -13.9 -14.4 02/21/2005 06:20:00 17.5 1.5 21.8 13.3 17.1 1.7 21 11.8 0.4 0 0.4 0.4 31 0 31 305 59 0 60 0 -14.4 0 -14.1 -14.6 02/21/2005 06:30:00 17.8 1.7 22.1 13.7 17.4 1.7 22.1 13.3 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.4 0 -14.1 -14.6 02/21/2005 06:40:00 16.5 1.4 20.6 12.6 16.1 1.5 20.2 12.2 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -14.6 0.1 -14.3 -14.6 02/21/2005 06:50:00 17.2 1.6 21 13 16.5 1.7 20.2 12.2 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -14.7 0 -14.4 -15 02/21/2005 07:00:00 17 1.8 21.4 13 16.6 1.7 21 12.6 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -14.7 0 -14.4 -14.8 02/21/2005 07:10:00 15 1.5 18.7 11.1 14.5 1.5 18.3 9.9 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -14.8 0 -14.4 -15 02/21/2005 07:20:00 16.2 1.7 21 13 15.8 1.7 21.4 12.2 0.4 0 0.4 0.4 31 0 31 305 56 0 56 0 -14.9 0 -14.6 -15 02/21/2005 07:30:00 16.9 1.7 21.8 12.6 16.3 1.8 21.4 12.2 0.4 0 0.4 0.4 31 0 31 305 56 0 56 0 -15 0 -14.6 -15 02/21/2005 07:40:00 16.1 2.3 22.1 12.2 15.6 2.3 21.4 11.8 0.4 0 0.4 0.4 31 0 31 305 56 0 55 0 -15 0.1 -14.6 -15.2 02/21/2005 07:50:00 15.5 1.7 20.2 11.5 15 1.6 19.9 11.1 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -15.2 0 -14.8 -15.4 02/21/2005 08:00:00 16.4 1.7 21 12.6 15.8 1.7 21 12.2 0.4 0 0.4 0.4 31 0 31 305 54 0 55 0 -15.3 0 -14.8 -15.4 02/21/2005 08:10:00 15.5 1.7 19.9 11.8 15 1.8 18.7 10.7 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -15.3 0 -15 -15.4 02/21/2005 08:20:00 15 1.5 19.1 11.1 14.4 1.6 19.5 10.3 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -15.3 0 -15 -15.4 02/21/2005 08:30:00 15.3 1.6 19.1 11.5 14.9 1.7 19.1 11.8 0.4 0 0.4 0.4 31 1 31 305 54 0 53 0 -15.3 0 -14.8 -15.4 02/21/2005 08:40:00 14.7 1.5 17.9 11.1 14.1 1.6 18.3 10.7 0.4 0 0.4 0.4 31 0 31 305 53 0 54 0 -15.3 0 -15 -15.6 02/21/2005 08:50:00 15.4 1.5 19.5 10.7 15 1.5 18.7 10.7 0.4 0 0.4 0.4 31 1 31 305 54 0 54 0 -15.2 0 -14.8 -15.4 02/21/2005 09:00:00 14.4 1.8 19.1 11.1 14 1.8 18.7 10.3 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -15.2 0 -14.8 -15.2 02/21/2005 09:10:00 14.1 1.8 19.5 10.3 13.5 1.8 19.1 9.5 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -15.3 0 -15 -15.6 02/21/2005 09:20:00 16.2 1.3 19.9 13 15.7 1.3 19.1 13 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -15.3 0 -15 -15.6 02/21/2005 09:30:00 14.8 1.6 19.9 10.7 14.3 1.7 19.1 10.7 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -15.4 0 -15 -15.6 02/21/2005 09:40:00 15.2 1.5 19.1 11.8 14.8 1.5 18.7 11.1 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -15.5 0 -15 -15.8 02/21/2005 09:50:00 15.5 1.8 20.2 10.7 15 1.8 19.5 10.7 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -15.6 0 -15.2 -15.6 02/21/2005 10:00:00 15.8 2.1 20.6 11.1 15.2 2.1 20.6 9.9 0.4 0 0.4 0.4 31 0 31 305 52 0 52 0 -15.6 0 -15.2 -15.8 02/21/2005 10:10:00 16.6 1.9 21 10.3 15.9 1.8 19.5 10.3 0.4 0 0.4 0.4 31 0 31 305 52 0 52 0 -15.5 0.1 -15.2 -15.8 02/21/2005 10:20:00 17.6 1.6 21 11.8 16.8 1.7 20.6 11.8 0.4 0 0.4 0.4 31 0 31 305 52 0 52 0 -15.6 0.1 -15.2 -15.8 02/21/2005 10:30:00 15.1 1.9 19.5 11.1 14.7 1.9 19.1 10.7 0.4 0 0.4 0.4 31 0 31 305 52 0 52 0 -15.6 0.1 -15.2 -15.8 02/21/2005 10:40:00 15.6 1.7 20.2 11.5 15.1 1.7 20.2 10.7 0.4 0 0.4 0.4 31 0 31 305 52 0 52 0 -15.5 0.1 -15 -15.8 02/21/2005 10:50:00 15.3 1.3 19.1 12.6 15 1.3 19.1 11.8 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -15.5 0 -15 -15.6 02/21/2005 11:00:00 15.9 1.5 19.9 12.2 15.3 1.4 19.1 11.8 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -15.4 0.1 -15 -15.6 02/21/2005 11:10:00 16.1 1.7 20.2 11.5 15.6 1.8 20.2 11.1 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -15.3 0 -14.8 -15.6 02/21/2005 11:20:00 16.8 1.7 21 12.6 16.1 1.7 21 12.2 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -15.3 0 -14.8 -15.4 02/21/2005 11:30:00 16 1.6 19.9 11.8 15.2 1.5 19.5 11.5 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -15.2 0 -14.8 -15.4 02/21/2005 11:40:00 16.2 1.7 21 12.2 15.5 1.7 19.9 10.7 0.4 0 0.4 0.4 31 0 31 305 56 0 56 0 -15.2 0 -14.8 -15.4 02/21/2005 11:50:00 14.9 1.6 18.7 10.7 14.3 1.6 18.3 9.5 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -15.1 0.1 -14.6 -15.2 02/21/2005 12:00:00 14.8 1.9 19.5 10.7 14.2 2 19.1 9.5 0.4 0 0.4 0.4 31 0 31 305 57 0 58 0 -15.1 0.1 -14.6 -15.2 02/21/2005 12:10:00 16 1.7 19.9 11.5 15.4 1.7 19.5 10.3 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -15 0.1 -14.4 -15 02/21/2005 12:20:00 15.3 1.8 20.2 11.1 14.8 1.7 19.5 10.3 0.4 0 0.4 0.4 31 0 31 305 60 0 61 0 -14.9 0 -14.4 -15 02/21/2005 12:30:00 15.2 1.7 19.5 10.7 14.6 1.7 18.7 10.7 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -14.8 0 -14.4 -15 02/21/2005 12:40:00 15.6 2 19.9 11.1 14.9 1.9 20.2 9.9 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.8 0 -14.4 -15 02/21/2005 12:50:00 17.5 1.3 21.8 13.7 16.8 1.4 20.2 13 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.9 0 -14.4 -15 02/21/2005 13:00:00 16.6 1.7 20.6 12.2 16 1.5 20.2 12.2 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.9 0 -14.4 -15 02/21/2005 13:10:00 18.2 2.1 22.6 13.3 17.3 2 21.8 12.2 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.9 0 -14.4 -15 02/21/2005 13:20:00 16.8 1.6 20.2 12.6 16 1.5 19.9 12.2 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -14.8 0 -14.4 -15 02/21/2005 13:30:00 15.3 1.7 19.1 11.1 14.7 1.7 18.7 10.7 0.4 0 0.4 0.4 31 0 31 305 63 0 63 0 -14.7 0 -14.3 -14.8 02/21/2005 13:40:00 14.1 1.7 17.6 10.7 13.6 1.5 16.8 10.3 0.4 0 0.4 0.4 31 0 31 305 64 1 64 0 -14.8 0 -14.4 -15 02/21/2005 13:50:00 14.6 1.3 17.6 11.1 14.1 1.4 17.2 10.3 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -14.9 0 -14.4 -15 02/21/2005 14:00:00 14.4 1.1 17.9 12.2 13.8 1.1 16.4 11.1 0.4 0 0.4 0.4 31 0 31 305 66 0 66 0 -15 0.1 -14.6 -15.2 02/21/2005 14:10:00 14.9 1.5 18.3 11.5 14.4 1.6 17.9 11.1 0.4 0 0.4 0.4 31 0 31 305 65 0 66 0 -15.3 0.1 -14.6 -15.6 02/21/2005 14:20:00 15.2 1.7 18.7 10.3 14.6 1.5 18.7 11.1 0.4 0 0.4 0.4 31 0 31 305 63 1 64 0 -15.4 0 -15 -15.6 02/21/2005 14:30:00 15.1 1.6 18.7 10.7 14.5 1.5 18.3 10.3 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -15.5 0 -15 -15.6 02/21/2005 14:40:00 15.6 1.5 19.1 12.2 14.9 1.5 19.1 11.1 0.4 0 0.4 0.4 31 0 31 305 60 0 60 0 -15.5 0 -15 -15.6 02/21/2005 14:50:00 15.9 1.5 19.1 12.6 15.3 1.4 18.7 11.8 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -15.5 0 -15 -15.6 02/21/2005 15:00:00 15 1.2 17.9 11.8 14.5 1.2 17.6 11.1 0.4 0 0.4 0.4 31 0 31 305 59 0 59 0 -15.3 0.1 -15 -15.6 02/21/2005 15:10:00 14.9 1.3 17.6 11.8 14.3 1.2 17.2 11.1 0.4 0 0.4 0.4 31 0 31 305 61 0 60 0 -15.4 0.1 -15 -15.6 02/21/2005 15:20:00 14.6 1.4 17.9 10.7 14.2 1.3 17.6 11.1 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -15.4 0 -15 -15.6 02/21/2005 15:30:00 15.1 1.3 19.1 11.5 14.5 1.3 19.9 10.3 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -15.4 0.1 -15 -15.6 02/21/2005 15:40:00 14.3 1.3 17.9 11.1 13.7 1.3 16.4 9.5 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -15.5 0 -15 -15.6 02/21/2005 15:50:00 14.9 1.3 17.6 10.7 14.6 1.3 17.6 11.1 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -15.4 0 -15 -15.6 02/21/2005 16:00:00 14.7 1.9 19.1 10.7 14.3 1.8 18.7 10.7 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -15.3 0.1 -15 -15.6 02/21/2005 16:10:00 15.2 1.4 18.7 10.7 14.7 1.5 18.3 10.3 0.4 0 0.4 0.4 31 0 31 305 62 0 63 0 -15.5 0.1 -15 -15.6 02/21/2005 16:20:00 14.2 1.2 17.6 11.5 13.8 1.2 17.2 11.1 0.4 0 0.4 0.4 31 0 31 305 62 0 62 0 -15.5 0 -15 -15.6 02/21/2005 16:30:00 13.8 1.4 17.6 9.9 13.3 1.5 17.2 9.9 0.4 0 0.4 0.4 31 0 31 305 61 0 61 0 -15.5 0 -15 -15.6 02/21/2005 16:40:00 13.4 1.5 17.6 9.9 13 1.5 17.2 9.9 0.4 0 0.4 0.4 31 0 31 305 60 0 59 0 -15.5 0.1 -15 -15.6 02/21/2005 16:50:00 14 1.5 17.9 10.7 13.6 1.5 17.6 9.9 0.4 0 0.4 0.4 31 0 31 305 59 0 58 0 -15.5 0 -15 -15.6 02/21/2005 17:00:00 13.1 1.2 16.8 10.3 12.8 1.3 16.4 9.9 0.4 0 0.4 0.4 31 0 31 305 58 0 58 0 -15.4 0 -15 -15.6 02/21/2005 17:10:00 13.1 1 15.6 10.3 12.8 1 15.6 10.3 0.4 0 0.4 0.4 31 0 31 305 57 0 58 0 -15.4 0 -15 -15.6 02/21/2005 17:20:00 13.3 1.4 17.2 9.9 13 1.5 16.8 9.9 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -15.4 0 -15 -15.6 02/21/2005 17:30:00 13.5 1.2 16.4 10.7 13 1.2 16.1 9.9 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -15.5 0 -15 -15.6 02/21/2005 17:40:00 12.5 1.6 16.4 9.5 12.2 1.6 16.4 9.1 0.4 0 0.4 0.4 31 0 31 305 56 0 57 0 -15.4 0 -15 -15.6 02/21/2005 17:50:00 14.3 1.7 17.9 10.7 14 1.7 18.3 10.7 0.4 0 0.4 0.4 31 0 31 305 56 0 57 0 -15.5 0.1 -15 -15.6 02/21/2005 18:00:00 14.4 1.6 17.9 10.3 13.9 1.5 17.6 9.1 0.4 0 0.4 0.4 31 0 31 305 56 0 57 0 -15.7 0.1 -15.2 -15.8 02/21/2005 18:10:00 13.5 1.5 17.2 9.9 13.1 1.4 16.8 10.7 0.4 0 0.4 0.4 31 0 31 305 56 0 56 0 -15.7 0.1 -15.2 -15.8 02/21/2005 18:20:00 13.5 1.5 18.3 9.5 13.1 1.5 17.6 8.8 0.4 0 0.4 0.4 31 0 31 305 56 0 56 0 -15.8 0 -15.4 -16 02/21/2005 18:30:00 15.7 1.5 19.5 11.8 15.1 1.5 18.7 10.7 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -15.9 0 -15.6 -16.2 02/21/2005 18:40:00 14.1 1.1 16.8 11.5 13.8 1.2 17.2 10.3 0.4 0 0.4 0.4 31 0 31 305 54 0 55 0 -16.2 0.1 -15.8 -16.4 02/21/2005 18:50:00 14.2 1.5 17.6 10.3 13.8 1.4 17.2 10.7 0.4 0 0.4 0.4 31 0 31 305 53 0 52 0 -16.3 0 -16 -16.4 02/21/2005 19:00:00 13.7 1.5 17.9 10.7 13.4 1.5 17.2 10.3 0.4 0 0.4 0.4 31 0 31 305 51 0 51 0 -16.2 0.1 -15.8 -16.4 02/21/2005 19:10:00 14.5 1.3 17.2 11.5 14.2 1.3 17.2 10.7 0.4 0 0.4 0.4 31 0 31 305 50 0 50 0 -16.3 0 -16 -16.4 02/21/2005 19:20:00 14.3 1.2 16.8 10.3 13.8 1.1 16.4 11.5 0.4 0 0.4 0.4 31 0 31 305 49 0 49 0 -16.4 0 -16 -16.6 02/21/2005 19:30:00 14.2 1.3 17.9 11.1 13.9 1.3 17.2 10.3 0.4 0 0.4 0.4 31 0 31 305 48 0 48 0 -16.4 0 -16 -16.6 02/21/2005 19:40:00 13.7 1 16.4 11.1 13.4 1.1 16.8 10.7 0.4 0 0.4 0.4 31 0 31 305 48 0 48 0 -16.4 0 -16 -16.6 02/21/2005 19:50:00 14.9 1.2 17.6 11.5 14.5 1.3 17.2 11.1 0.4 0 0.4 0.4 31 0 31 305 47 0 47 0 -16.4 0 -16 -16.6 02/21/2005 20:00:00 14.8 1.3 17.6 11.5 14.4 1.4 17.6 10.7 0.4 0 0.4 0.4 31 0 31 305 47 0 47 0 -16.3 0 -16 -16.6 02/21/2005 20:10:00 15.4 1.1 17.6 12.2 14.8 1.2 17.6 11.8 0.4 0 0.4 0.4 31 0 31 305 47 0 47 0 -16.4 0 -16 -16.6 02/21/2005 20:20:00 14 1.2 17.2 11.1 13.7 1.2 17.2 10.3 0.4 0 0.4 0.4 31 0 31 305 47 0 47 0 -16.4 0 -16 -16.6 02/21/2005 20:30:00 14.6 1.2 17.2 11.8 14.3 1.1 17.2 11.5 0.4 0 0.4 0.4 31 0 31 305 47 0 47 0 -16.4 0 -16 -16.6 02/21/2005 20:40:00 13.6 1.2 16.8 11.1 13.3 1.2 16.4 9.9 0.4 0 0.4 0.4 31 0 31 305 47 0 47 0 -16.5 0.1 -16.2 -16.7 02/21/2005 20:50:00 13.9 1.4 17.6 10.7 13.5 1.5 17.2 9.9 0.4 0 0.4 0.4 31 0 31 305 47 0 46 0 -16.6 0 -16.4 -16.9 02/21/2005 21:00:00 12.8 1.1 14.9 9.5 12.6 1.2 15.3 9.1 0.4 0 0.4 0.4 31 0 31 305 46 0 46 0 -16.9 0 -16.4 -16.9 02/21/2005 21:10:00 13.1 1 15.3 10.3 12.9 1 15.3 10.3 0.4 0 0.4 0.4 31 0 31 305 46 0 46 0 -16.9 0 -16.6 -16.9 02/21/2005 21:20:00 13.1 1 15.3 10.3 12.8 1 15.6 9.9 0.4 0 0.4 0.4 31 0 31 305 45 0 45 0 -16.9 0 -16.7 -16.9 02/21/2005 21:30:00 12.6 1.1 15.3 10.3 12.4 1.1 15.3 9.9 0.4 0 0.4 0.4 31 0 31 305 45 0 45 0 -17.1 0 -16.9 -17.3 02/21/2005 21:40:00 13.3 1.1 16.1 10.3 13 1.1 16.1 9.9 0.4 0 0.4 0.4 31 0 31 305 44 0 44 0 -17.1 0 -16.9 -17.3 02/21/2005 21:50:00 12.8 1 15.3 9.9 12.6 1.1 15.3 10.3 0.4 0 0.4 0.4 31 0 31 305 44 0 43 0 -17.2 0 -16.9 -17.5 02/21/2005 22:00:00 12.7 0.9 15.6 10.3 12.5 1.1 15.6 9.1 0.4 0 0.4 0.4 31 0 31 305 43 0 43 0 -17.3 0.1 -16.9 -17.5 02/21/2005 22:10:00 11.9 1 15.3 9.5 11.6 1.1 14.5 9.5 0.4 0 0.4 0.4 31 0 31 305 43 0 43 0 -17.3 0 -16.9 -17.5 02/21/2005 22:20:00 12.7 1.1 15.6 9.9 12.5 1.2 15.6 9.5 0.4 0 0.4 0.4 31 0 31 305 43 0 42 0 -17.3 0 -16.9 -17.5 02/21/2005 22:30:00 14.7 1.2 17.6 11.5 14.4 1.3 17.6 10.7 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.3 0 -16.9 -17.5 02/21/2005 22:40:00 13.9 1.2 16.8 11.1 13.6 1.2 16.4 10.3 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.3 0.1 -16.9 -17.5 02/21/2005 22:50:00 13.9 1 16.4 11.1 13.6 1 15.6 10.3 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.3 0 -16.9 -17.3 02/21/2005 23:00:00 13.5 1.2 16.1 10.7 13.4 1.2 16.1 10.3 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0 -16.9 -17.3 02/21/2005 23:10:00 12.9 1.1 15.6 10.3 12.6 1.1 15.3 9.9 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0 -16.9 -17.3 02/21/2005 23:20:00 13.1 1 16.1 10.7 12.9 1 15.6 10.3 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.1 0 -16.9 -17.3 02/21/2005 23:30:00 13.7 1 16.1 11.5 13.4 1 16.4 11.1 0.4 0 0.4 0.4 31 0 31 305 43 0 42 0 -16.9 0 -16.6 -17.1 02/21/2005 23:40:00 14.7 1.1 17.2 11.8 14.3 1.1 16.8 11.8 0.4 0 0.4 0.4 31 0 31 305 43 0 43 0 -16.7 0.1 -16.4 -16.9 02/21/2005 23:50:00 13.9 1.2 16.8 10.7 13.6 1.3 17.2 9.5 0.4 0 0.4 0.4 31 0 31 305 43 0 44 0 -16.7 0 -16.4 -16.9 02/22/2005 00:00:00 13.9 1.3 16.8 10.7 13.6 1.3 16.8 10.7 0.4 0 0.4 0.4 31 0 31 305 44 0 44 0 -16.6 0 -16.2 -16.9 02/22/2005 00:10:00 13.8 1.6 17.6 10.7 13.4 1.5 17.2 9.9 0.4 0 0.4 0.4 31 0 31 305 45 0 45 0 -16.6 0 -16.4 -16.7 02/22/2005 00:20:00 13.7 1.3 17.6 10.7 13.4 1.4 16.8 9.9 0.4 0 0.4 0.4 31 0 31 305 45 0 45 0 -16.6 0.1 -16.2 -16.9 02/22/2005 00:30:00 14.3 1 16.8 11.5 14 1.1 16.4 11.1 0.4 0 0.4 0.4 31 0 31 305 45 0 45 0 -16.7 0.1 -16.4 -16.9 02/22/2005 00:40:00 13.5 0.9 15.3 10.7 13.3 1 15.6 10.7 0.4 0 0.4 0.4 31 0 31 305 45 0 45 0 -16.9 0 -16.4 -16.9 02/22/2005 00:50:00 13.9 1.2 16.8 11.5 13.6 1.2 16.8 10.7 0.4 0 0.4 0.4 31 0 31 305 44 0 44 0 -16.9 0 -16.9 -16.9 02/22/2005 01:00:00 13 1.5 16.4 9.9 12.7 1.6 16.4 9.5 0.4 0 0.4 0.4 31 0 31 305 44 0 44 0 -16.9 0 -16.6 -16.9 02/22/2005 01:10:00 14 1.2 17.6 10.7 13.7 1.3 17.2 10.3 0.4 0 0.4 0.4 31 0 31 305 43 0 43 0 -16.9 0 -16.9 -17.1 02/22/2005 01:20:00 13.5 1.4 16.8 10.7 13.2 1.4 16.1 10.3 0.4 0 0.4 0.4 31 0 31 305 43 0 43 0 -17.1 0 -16.9 -17.3 02/22/2005 01:30:00 13.1 1.1 15.6 9.9 12.8 1.1 15.3 9.9 0.4 0 0.4 0.4 31 0 31 305 43 0 42 0 -17.1 0 -16.9 -17.3 02/22/2005 01:40:00 13.2 1 16.4 9.9 13 1.1 16.1 9.9 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0 -16.9 -17.3 02/22/2005 01:50:00 13.3 1.4 16.4 9.5 13 1.5 16.4 9.9 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.3 0 -17.1 -17.5 02/22/2005 02:00:00 13.4 1.1 16.4 10.7 13.2 1.1 16.1 9.9 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.4 0 -16.9 -17.5 02/22/2005 02:10:00 12.3 1 14.9 9.5 12 1 14.9 9.5 0.4 0 0.4 0.4 31 0 31 305 41 0 41 0 -17.5 0 -17.1 -17.5 02/22/2005 02:20:00 12.2 1.1 14.9 9.5 11.9 1.1 14.5 9.1 0.4 0 0.4 0.4 31 0 31 305 41 0 41 0 -17.4 0 -17.1 -17.5 02/22/2005 02:30:00 12.7 0.9 14.9 9.9 12.4 1 14.5 9.9 0.4 0 0.4 0.4 31 0 31 305 41 0 41 0 -17.4 0 -16.9 -17.5 02/22/2005 02:40:00 12.3 1 14.5 9.9 12 1 14.5 9.5 0.4 0 0.4 0.4 31 0 31 305 41 0 41 0 -17.4 0 -17.1 -17.5 02/22/2005 02:50:00 12.2 0.9 14.1 9.9 11.8 1 14.1 9.1 0.4 0 0.4 0.4 31 0 31 305 41 0 41 0 -17.4 0 -17.1 -17.5 02/22/2005 03:00:00 12.6 0.9 15.3 9.9 12.4 1 14.9 9.9 0.4 0 0.4 0.4 31 0 31 305 41 0 41 0 -17.4 0 -17.1 -17.5 02/22/2005 03:10:00 12.8 1 15.6 10.3 12.6 1 15.3 10.3 0.4 0 0.4 0.4 31 0 31 305 41 0 41 0 -17.4 0 -17.1 -17.5 02/22/2005 03:20:00 12.6 0.9 14.9 9.5 12.4 1 14.9 9.5 0.4 0 0.4 0.4 31 0 31 305 41 0 40 0 -17.5 0 -17.1 -17.7 02/22/2005 03:30:00 13 1 15.6 10.7 12.7 1.1 15.6 9.9 0.4 0 0.4 0.4 31 0 31 305 40 0 40 0 -17.5 0 -17.1 -17.5 02/22/2005 03:40:00 13.5 1.2 16.4 11.1 13.2 1.3 16.4 10.3 0.4 0 0.4 0.4 31 0 31 305 40 0 40 0 -17.5 0 -17.1 -17.5 02/22/2005 03:50:00 14.7 1 16.8 12.2 14.4 1 16.4 11.8 0.4 0 0.4 0.4 31 0 31 305 40 0 40 0 -17.5 0 -17.1 -17.5 02/22/2005 04:00:00 14.8 1 16.8 12.2 14.6 1 16.8 11.8 0.4 0 0.4 0.4 31 0 31 305 40 0 40 0 -17.4 0 -17.1 -17.5 02/22/2005 04:10:00 14.4 1.2 17.9 11.8 14 1.2 16.8 11.1 0.4 0 0.4 0.4 31 0 31 305 40 0 40 0 -17.4 0 -17.1 -17.5 02/22/2005 04:20:00 13.4 1 16.8 11.8 13.1 1 16.4 11.1 0.4 0 0.4 0.4 31 0 31 305 40 0 40 0 -17.4 0 -17.1 -17.5 02/22/2005 04:30:00 14 1.3 17.2 11.1 13.6 1.3 16.8 10.3 0.4 0 0.4 0.4 31 0 31 305 40 0 40 0 -17.4 0 -16.9 -17.5 02/22/2005 04:40:00 14.5 1.2 17.6 11.8 14.1 1.3 16.8 11.1 0.4 0 0.4 0.4 31 0 31 305 40 0 40 0 -17.3 0 -16.9 -17.5 02/22/2005 04:50:00 15.2 1.1 17.9 12.6 14.8 1.3 17.9 11.8 0.4 0 0.4 0.4 31 0 31 305 41 0 41 0 -17.2 0 -16.9 -17.3 02/22/2005 05:00:00 15 1.2 17.6 11.5 14.8 1.3 17.6 11.5 0.4 0 0.4 0.4 31 0 31 305 41 0 41 0 -17.2 0 -17.1 -17.3 02/22/2005 05:10:00 14.9 1 17.2 11.5 14.8 1.1 17.2 11.8 0.4 0 0.4 0.4 31 0 31 305 41 0 41 0 -17.2 0 -16.9 -17.3 02/22/2005 05:20:00 13.3 1.2 16.1 10.3 13 1.2 16.4 9.9 0.4 0 0.4 0.4 31 0 31 305 41 0 41 0 -17.1 0 -16.9 -17.3 02/22/2005 05:30:00 13.1 1 15.6 10.7 12.9 1 15.3 10.3 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0 -16.9 -17.3 02/22/2005 05:40:00 12.7 1 15.3 10.3 12.5 1 14.9 9.9 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.1 0 -16.9 -17.3 02/22/2005 05:50:00 11.8 0.9 14.5 9.1 11.5 1 14.1 9.1 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.1 0 -16.9 -17.1 02/22/2005 06:00:00 11.5 1 14.1 9.1 11.3 1.1 14.1 8.8 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.1 0 -16.9 -17.3 02/22/2005 06:10:00 12.7 1.7 16.1 9.5 12.4 1.7 16.4 9.5 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.1 0 -16.9 -17.3 02/22/2005 06:20:00 14.1 1 16.4 11.5 13.8 1 16.1 11.1 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.1 0 -16.9 -17.3 02/22/2005 06:30:00 13.6 1 16.1 10.3 13.3 1 16.1 10.7 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.1 0 -16.9 -17.3 02/22/2005 06:40:00 12.4 1 14.5 9.5 12.1 1.1 14.5 9.1 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0 -16.9 -17.3 02/22/2005 06:50:00 12.4 0.8 14.5 9.9 12 0.9 14.5 9.5 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.3 0.1 -16.9 -17.5 02/22/2005 07:00:00 12.1 1.1 14.9 9.1 11.8 1.2 14.5 8.4 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.3 0 -16.9 -17.3 02/22/2005 07:10:00 12.2 0.8 13.7 9.9 11.9 0.9 13.7 9.5 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0 -16.9 -17.3 02/22/2005 07:20:00 11.4 1 13.3 8.4 11.1 1 13.3 8 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0.1 -16.9 -17.3 02/22/2005 07:30:00 12.9 1.4 15.6 9.1 12.6 1.5 15.6 9.5 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0 -16.9 -17.3 02/22/2005 07:40:00 13.8 1.1 16.1 10.7 13.6 1.2 16.1 9.9 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0.1 -16.9 -17.3 02/22/2005 07:50:00 12.8 1.3 16.4 9.9 12.4 1.3 16.4 9.5 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0 -16.9 -17.3 02/22/2005 08:00:00 13 1.3 16.8 10.3 12.7 1.5 16.8 9.5 0.4 0 0.4 0.4 31 0 31 305 42 0 41 0 -17.1 0 -16.9 -17.3 02/22/2005 08:10:00 11.4 1 14.1 8.8 11.1 1 13.7 8.4 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0 -16.9 -17.5 02/22/2005 08:20:00 11 1.3 13.7 8.4 10.6 1.4 13.7 7.6 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0 -16.9 -17.3 02/22/2005 08:30:00 11.8 0.9 14.1 9.5 11.5 1 13.7 9.1 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.1 0 -16.9 -17.3 02/22/2005 08:40:00 10.9 1.2 14.5 8 10.6 1.2 14.1 8 0.4 0 0.4 0.4 31 0 31 305 42 0 41 0 -17.2 0 -16.9 -17.3 02/22/2005 08:50:00 12 1 14.5 9.5 11.6 1 13.7 8.8 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.3 0 -16.9 -17.3 02/22/2005 09:00:00 12 1.2 14.9 8.8 11.6 1.3 14.9 8 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.2 0 -16.9 -17.3 02/22/2005 09:10:00 11.3 1.2 14.1 8.4 11 1.2 13.3 8.8 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17.1 0 -16.9 -17.3 02/22/2005 09:20:00 11.3 1.2 14.9 8.8 11 1.2 14.9 8.4 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -17 0 -16.9 -17.1 02/22/2005 09:30:00 13 0.8 14.5 10.3 12.6 1 14.5 9.5 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -16.9 0 -16.9 -16.9 02/22/2005 09:40:00 12.2 1.1 15.3 9.5 11.9 1.1 14.5 9.5 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -16.9 0 -16.9 -16.9 02/22/2005 09:50:00 12.1 1.1 14.9 9.1 11.8 1.2 14.5 8.8 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -16.9 0 -16.9 -16.9 02/22/2005 10:00:00 10.8 1.1 13 8.4 10.6 1.2 14.1 8 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -16.9 0 -16.6 -16.9 02/22/2005 10:10:00 11.4 1.1 14.1 7.2 11.2 1.1 14.1 8 0.4 0 0.4 0.4 31 0 31 305 42 0 42 0 -16.9 0 -16.6 -16.9 02/22/2005 10:20:00 11.5 1 14.1 9.1 11.2 1 14.1 9.1 0.4 0 0.4 0.4 31 0 31 305 43 0 42 0 -17 0 -16.6 -17.1 02/22/2005 10:30:00 11.3 1 13.7 8.8 10.9 1.1 13.7 8 0.4 0 0.4 0.4 31 0 31 305 43 0 43 0 -17.1 0 -16.9 -17.3 02/22/2005 10:40:00 11.9 1 14.1 9.5 11.6 1 13.7 9.1 0.4 0 0.4 0.4 31 0 31 305 43 0 43 0 -17.1 0 -16.9 -17.3 02/22/2005 10:50:00 11.4 1.1 14.5 8.8 11.1 1.2 14.9 8.8 0.4 0 0.4 0.4 31 0 31 305 43 0 43 0 -17 0 -16.9 -17.3 02/22/2005 11:00:00 11.7 1 14.1 9.1 11.4 1 13.7 8.8 0.4 0 0.4 0.4 31 0 31 305 43 0 43 0 -17 0 -16.6 -17.3 02/22/2005 11:10:00 11.7 1.2 14.9 8.8 11.4 1.2 14.9 8.8 0.4 0 0.4 0.4 31 0 31 305 43 0 43 0 -17 0 -16.6 -17.1 02/22/2005 11:20:00 11.6 1 14.1 9.1 11.2 1 13.7 8.4 0.4 0 0.4 0.4 31 0 31 305 44 0 43 0 -16.9 0 -16.6 -16.9 02/22/2005 11:30:00 10.5 1 14.5 8 10.3 1 13.7 8 0.4 0 0.4 0.4 31 0 31 305 46 0 45 0 -16.9 0 -16.6 -17.1 02/22/2005 11:40:00 13 1.1 15.3 9.5 12.6 1.2 15.3 9.5 0.4 0 0.4 0.4 31 0 31 305 46 0 46 0 -16.9 0 -16.6 -16.9 02/22/2005 11:50:00 12.8 1 15.3 10.3 12.6 1 14.9 9.9 0.4 0 0.4 0.4 31 0 31 305 48 0 47 0 -16.9 0 -16.6 -16.9 02/22/2005 12:00:00 13.6 1.1 16.1 9.9 13.3 1.2 16.1 9.9 0.4 0 0.4 0.4 31 0 31 305 49 0 49 0 -16.9 0 -16.6 -17.1 02/22/2005 12:10:00 13.5 1.3 17.2 9.9 13.1 1.4 16.4 9.1 0.4 0 0.4 0.4 31 0 31 305 49 0 49 0 -17 0 -16.6 -17.1 02/22/2005 12:20:00 13.9 1 16.8 11.5 13.6 1.1 16.4 11.1 0.4 0 0.4 0.4 31 0 31 305 49 0 49 0 -17 0 -16.6 -17.1 02/22/2005 12:30:00 13.6 1.2 16.4 10.3 13.2 1.2 16.1 10.3 0.4 0 0.4 0.4 31 0 31 305 49 0 49 0 -16.9 0 -16.6 -17.1 02/22/2005 12:40:00 13.1 1.2 16.1 9.9 12.8 1.2 16.1 9.9 0.4 0 0.4 0.4 31 0 31 305 50 0 50 0 -16.9 0 -16.6 -16.9 02/22/2005 12:50:00 12.8 1 15.6 10.7 12.5 1 14.9 9.9 0.4 0 0.4 0.4 31 0 31 305 50 0 50 0 -16.9 0 -16.6 -16.9 02/22/2005 13:00:00 13 1.3 16.1 9.9 12.7 1.3 16.1 9.5 0.4 0 0.4 0.4 31 0 31 305 51 0 51 0 -16.8 0 -16.4 -16.9 02/22/2005 13:10:00 13.5 1.2 16.1 10.7 13.2 1.2 16.1 9.9 0.4 0 0.4 0.4 31 0 31 305 52 0 52 0 -16.8 0.1 -16.4 -16.9 02/22/2005 13:20:00 12.8 1.2 15.6 9.9 12.6 1.2 15.6 9.5 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -16.7 0.1 -16.2 -16.9 02/22/2005 13:30:00 13 1.3 16.1 9.5 12.6 1.3 16.1 9.5 0.4 0 0.4 0.4 31 0 31 305 53 0 53 0 -16.7 0 -16.6 -16.9 02/22/2005 13:40:00 13.3 1 16.1 9.9 12.9 1.1 16.1 9.5 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -16.7 0 -16.4 -16.9 02/22/2005 13:50:00 12.8 1 15.6 9.5 12.5 1 15.6 9.1 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -16.6 0 -16 -16.9 02/22/2005 14:00:00 12 1.2 14.5 9.1 11.8 1.2 14.1 8.8 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -16.5 0 -16 -16.6 02/22/2005 14:10:00 12.5 1.6 16.1 8.4 12.1 1.5 15.3 8.8 0.4 0 0.4 0.4 31 0 31 305 54 0 54 0 -16.6 0 -16.2 -16.9 02/22/2005 14:20:00 13.4 1.1 16.1 10.3 12.9 1.1 15.6 9.5 0.4 0 0.4 0.4 31 0 32 305 54 0 54 0 -16.5 0 -16.4 -16.7 02/22/2005 14:30:00 12.1 1.2 14.9 9.5 11.8 1.2 14.5 8.8 0.4 0 0.4 0.4 31 0 31 305 54 0 53 0 -16.5 0 -16.4 -16.6 02/22/2005 14:40:00 11.7 1.5 15.3 8.4 11.4 1.4 15.3 8 0.4 0 0.4 0.4 31 0 32 305 53 0 53 0 -16.4 0 -16 -16.6 02/22/2005 14:50:00 12.8 1 14.9 9.9 12.4 1 14.5 9.5 0.4 0 0.4 0.4 31 0 32 305 55 1 54 0 -16.5 0 -16.4 -16.7 02/22/2005 15:00:00 11.7 1.2 14.1 8.4 11.3 1.2 14.5 7.6 0.4 0 0.4 0.4 31 0 31 305 56 0 55 0 -16.4 0 -16 -16.6 02/22/2005 15:10:00 11.9 1.5 14.9 7.6 11.6 1.5 14.5 7.2 0.4 0 0.4 0.4 31 0 31 305 57 0 57 0 -16.5 0.1 -16.2 -16.9 02/22/2005 15:20:00 12.1 1.3 14.5 8.4 11.7 1.3 14.5 8.4 0.4 0 0.4 0.4 31 0 31 305 56 0 57 0 -16.6 0 -16.4 -16.9 02/22/2005 15:30:00 10.8 1.2 14.1 7.6 10.6 1.1 14.1 7.6 0.4 0 0.4 0.4 31 0 31 305 54 0 55 0 -16.5 0 -16.4 -16.6 02/22/2005 15:40:00 9.8 1.2 13 7.2 9.6 1.3 13 7.2 0.4 0 0.4 0.4 31 0 31 305 55 0 55 0 -16.4 0 -16 -16.6 02/22/2005 15:50:00 11.2 1.5 14.9 8 10.8 1.5 14.1 8 0.4 0 0.4 0.4 31 5 29 305 56 1 57 0 -16.5 0.1 -16 -16.7 02/22/2005 16:00:00 11.5 1.4 14.1 8 11.2 1.4 14.1 8 0.4 0 0.4 0.4 31 5 24 305 57 0 57 0 -16.6 0 -16.2 -16.9 02/22/2005 16:10:00 12.2 1 14.5 9.5 11.8 1.1 14.5 8.8 0.4 0 0.4 0.4 34 5 32 305 55 1 55 0 -16.6 0 -16 -16.7 02/22/2005 16:20:00 11.9 1 13.7 9.1 11.7 1 13.7 9.1 0.4 0 0.4 0.4 38 6 33 305 53 0 52 0 -16.5 0.1 -16 -16.6 02/22/2005 16:30:00 12.1 1.2 14.5 9.1 11.8 1.2 14.5 9.1 0.4 0 0.4 0.4 40 5 34 305 51 0 51 0 -16.5 0 -16 -16.6 02/22/2005 16:40:00 12.3 1.2 15.3 9.1 12 1.2 15.3 9.1 0.4 0 0.4 0.4 35 5 35 305 51 0 52 0 -16.5 0.1 -16 -16.7 02/22/2005 16:50:00 11.1 1.2 13.3 7.6 10.8 1.2 13.7 7.2 0.4 0 0.4 0.4 35 5 32 305 52 0 52 0 -16.5 0.1 -16 -16.6 02/22/2005 17:00:00 11 1.1 14.1 8.4 10.8 1.2 13.7 8 0.4 0 0.4 0.4 37 6 33 305 51 0 51 0 -16.5 0 -16 -16.6 02/22/2005 17:10:00 11.5 1 14.1 9.1 11.3 1 13.7 8.8 0.4 0 0.4 0.4 36 5 33 305 51 0 51 0 -16.5 0.1 -16 -16.7 02/22/2005 17:20:00 10.3 1 12.2 7.6 10 1.1 12.6 6.8 0.4 0 0.4 0.4 35 6 40 305 51 0 51 0 -16.6 0 -16 -16.7 02/22/2005 17:30:00 11.7 1.2 14.5 8.8 11.4 1.2 14.5 8.8 0.4 0 0.4 0.4 33 5 38 305 51 0 51 0 -16.6 0.1 -16.2 -16.9 02/22/2005 17:40:00 11.6 1 14.5 9.1 11.4 1.1 14.1 8.4 0.4 0 0.4 0.4 33 6 38 305 50 0 51 0 -16.7 0.1 -16.2 -16.9 02/22/2005 17:50:00 11.3 1.2 13.7 8 11.1 1.3 13.7 7.2 0.4 0 0.4 0.4 35 5 40 305 49 0 50 0 -16.8 0.1 -16.4 -16.9 02/22/2005 18:00:00 11.8 1.2 14.5 8.8 11.4 1.2 14.5 8.4 0.4 0 0.4 0.4 35 5 27 305 48 0 48 0 -16.9 0 -16.4 -16.9 02/22/2005 18:10:00 10.8 1 13.3 8.4 10.6 1 13.3 8.4 0.4 0 0.4 0.4 34 5 32 305 47 0 47 0 -16.9 0 -16.6 -16.9 02/22/2005 18:20:00 10.8 0.8 12.6 8.4 10.6 0.8 12.2 8.4 0.4 0 0.4 0.4 31 5 26 305 47 0 46 0 -16.9 0 -16.6 -16.9 02/22/2005 18:30:00 11.3 0.9 13.3 8.8 11 1 13 8.4 0.4 0 0.4 0.4 34 5 28 305 46 0 46 0 -16.9 0 -16.6 -16.9 02/22/2005 18:40:00 12 1.2 15.3 8.8 11.8 1.2 15.6 9.1 0.4 0 0.4 0.4 36 6 31 305 45 0 45 0 -16.9 0 -16.6 -16.9 02/22/2005 18:50:00 12 0.9 13.7 9.5 11.8 0.9 13.7 9.1 0.4 0 0.4 0.4 37 5 40 305 45 0 45 0 -16.9 0 -16.7 -16.9 02/22/2005 19:00:00 11.6 1 14.5 9.1 11.3 1 14.5 8.4 0.4 0 0.4 0.4 35 5 31 305 44 0 44 0 -16.9 0 -16.6 -16.9 02/22/2005 19:10:00 10.6 0.8 12.2 8.4 10.3 0.9 12.2 8 0.4 0 0.4 0.4 38 5 42 305 43 0 43 0 -16.9 0 -16.9 -17.1 02/22/2005 19:20:00 11.3 1 13.3 8.4 11 1 13.7 8.4 0.4 0 0.4 0.4 38 5 33 305 43 0 43 0 -16.9 0 -16.9 -17.1 02/22/2005 19:30:00 10.8 0.9 13 8 10.5 1 13.3 8 0.4 0 0.4 0.4 37 6 46 305 42 0 42 0 -17 0 -16.9 -17.1 02/22/2005 19:40:00 11.2 0.9 14.1 9.1 10.9 0.8 13.3 8.4 0.4 0 0.4 0.4 37 5 43 305 42 0 42 0 -17 0 -16.9 -17.1 02/22/2005 19:50:00 11 1.1 13.7 8 10.7 1.1 13.7 8 0.4 0 0.4 0.4 36 5 31 305 41 0 41 0 -17.1 0 -16.9 -17.3 02/22/2005 20:00:00 11.3 1.1 13.7 8.4 11 1.1 13.7 8.4 0.4 0 0.4 0.4 35 5 32 305 41 0 40 0 -17.1 0 -16.9 -17.3 02/22/2005 20:10:00 11.8 1 14.1 9.1 11.5 1 13.7 8.4 0.4 0 0.4 0.4 36 5 44 305 40 0 41 0 -17.2 0 -16.9 -17.3 02/22/2005 20:20:00 11.5 1 13.7 8.8 11.2 1.1 14.1 8.4 0.4 0 0.4 0.4 37 5 38 305 40 0 40 0 -17.3 0 -16.9 -17.5 02/22/2005 20:30:00 11 0.8 13.3 8.8 10.7 0.8 13 8.8 0.4 0 0.4 0.4 36 5 32 305 40 0 40 0 -17.3 0 -16.9 -17.5 02/22/2005 20:40:00 11.4 0.9 14.1 8.8 11.2 1 13.7 8.8 0.4 0 0.4 0.4 37 5 38 305 39 0 39 0 -17.3 0 -16.9 -17.5 02/22/2005 20:50:00 11.7 0.9 14.5 9.5 11.4 1 14.9 8.8 0.4 0 0.4 0.4 37 5 37 305 39 0 39 0 -17.3 0 -16.9 -17.5 02/22/2005 21:00:00 11.4 1.1 14.5 8.8 11.1 1.2 14.5 8 0.4 0 0.4 0.4 39 5 33 305 39 0 39 0 -17.4 0 -16.9 -17.5 02/22/2005 21:10:00 10.6 1 13.3 8.4 10.3 1 13.3 8 0.4 0 0.4 0.4 38 5 41 305 39 0 39 0 -17.4 0 -16.9 -17.5 02/22/2005 21:20:00 10.1 0.9 12.2 7.6 9.7 0.8 12.2 8 0.4 0 0.4 0.4 38 5 43 305 39 0 39 0 -17.4 0 -16.9 -17.5 02/22/2005 21:30:00 10.9 1 13.7 8.4 10.7 1 13.3 8.4 0.4 0 0.4 0.4 36 5 41 305 39 0 39 0 -17.4 0 -16.9 -17.5 02/22/2005 21:40:00 11.1 0.9 13.3 8.8 10.8 0.9 13 8 0.4 0 0.4 0.4 36 6 37 305 38 0 38 0 -17.3 0.1 -16.9 -17.5 02/22/2005 21:50:00 11.3 1.1 14.1 8.4 11.1 1.2 14.5 7.6 0.4 0 0.4 0.4 37 6 35 305 38 0 38 0 -17.3 0.1 -16.9 -17.5 02/22/2005 22:00:00 11 0.9 13.3 8.8 10.6 0.9 13.7 8 0.4 0 0.4 0.4 37 5 40 305 38 0 38 0 -17.3 0.1 -16.9 -17.5 02/22/2005 22:10:00 9.6 1.2 12.6 6.8 9.2 1.2 13 6.8 0.4 0 0.4 0.4 34 5 27 305 38 0 38 0 -17.4 0 -16.9 -17.5 02/22/2005 22:20:00 10.1 1.1 13.3 7.6 9.8 1.2 13.3 7.2 0.4 0 0.4 0.4 33 6 40 305 38 0 38 0 -17.4 0 -16.9 -17.5 02/22/2005 22:30:00 10.8 1.2 13.7 8.4 10.6 1.2 13.7 8 0.4 0 0.4 0.4 37 6 35 305 38 0 38 0 -17.4 0 -16.9 -17.5 02/22/2005 22:40:00 11.3 1.4 14.5 8 10.9 1.4 14.9 8 0.4 0 0.4 0.4 36 6 29 305 38 0 38 0 -17.4 0 -17.3 -17.5 02/22/2005 22:50:00 10.2 1 12.6 7.6 9.9 1 12.6 7.6 0.4 0 0.4 0.4 36 6 27 305 38 0 38 0 -17.4 0 -17.3 -17.5 02/22/2005 23:00:00 10.4 1 13.3 8 10.2 1 12.2 7.6 0.4 0 0.4 0.4 36 5 32 305 38 0 38 0 -17.4 0 -16.9 -17.5 02/22/2005 23:10:00 10.2 0.9 12.2 8 9.9 1 12.6 7.6 0.4 0 0.4 0.4 37 5 39 305 38 0 38 0 -17.5 0 -17.3 -17.5 02/22/2005 23:20:00 10.3 1 12.6 7.6 10 1 12.6 7.6 0.4 0 0.4 0.4 36 6 28 305 38 0 38 0 -17.5 0 -17.3 -17.5 02/22/2005 23:30:00 9.8 1.1 12.6 7.2 9.6 1.1 13.3 6.8 0.4 0 0.4 0.4 35 5 38 305 38 0 38 0 -17.5 0 -17.1 -17.5 02/22/2005 23:40:00 9.5 0.8 11.5 7.6 9.2 0.8 11.5 7.6 0.4 0 0.4 0.4 33 5 34 305 37 0 38 0 -17.5 0 -17.3 -17.5 02/22/2005 23:50:00 9 1 11.8 6.5 8.8 1 11.5 6.5 0.4 0 0.4 0.4 33 5 35 305 37 0 38 0 -17.5 0 -17.5 -17.7 02/23/2005 00:00:00 8 0.7 9.9 5.7 7.7 0.7 9.5 5.3 0.4 0 0.4 0.4 31 5 35 305 37 0 37 0 -17.6 0 -17.1 -17.7 02/23/2005 00:10:00 8 0.8 9.9 6.1 7.8 0.9 10.3 5.7 0.4 0 0.4 0.4 28 5 21 305 37 0 37 0 -17.6 0 -17.3 -17.9 02/23/2005 00:20:00 8.3 0.9 10.7 6.5 8 0.9 10.3 5.7 0.4 0 0.4 0.4 31 6 27 305 36 0 36 0 -17.6 0 -17.3 -17.9 02/23/2005 00:30:00 9 0.9 11.1 6.5 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 32 6 30 305 36 0 36 0 -17.6 0 -17.3 -17.9 02/23/2005 00:40:00 10.2 1.3 14.1 6.8 9.9 1.3 14.1 7.2 0.4 0 0.4 0.4 34 6 39 305 36 0 36 0 -17.6 0 -17.3 -17.9 02/23/2005 00:50:00 11.1 1.3 14.1 7.6 10.8 1.2 14.1 7.6 0.4 0 0.4 0.4 35 5 41 305 36 0 36 0 -17.5 0 -17.3 -17.7 02/23/2005 01:00:00 11 0.9 13 8.4 10.6 1 12.6 8.4 0.4 0 0.4 0.4 35 5 28 305 36 0 36 0 -17.6 0 -17.3 -17.7 02/23/2005 01:10:00 10.7 1 13 8 10.4 1 13.3 7.6 0.4 0 0.4 0.4 35 5 38 305 36 0 36 0 -17.6 0 -17.3 -17.9 02/23/2005 01:20:00 10.3 1.1 12.6 7.2 10 1.1 12.2 7.2 0.4 0 0.4 0.4 35 5 34 305 36 0 36 0 -17.6 0 -17.3 -17.9 02/23/2005 01:30:00 9.7 1 12.2 7.2 9.5 0.9 11.8 6.8 0.4 0 0.4 0.4 33 5 27 305 36 0 36 0 -17.7 0 -17.5 -17.9 02/23/2005 01:40:00 10.1 1 13 8 9.8 1 12.6 7.6 0.4 0 0.4 0.4 36 6 32 305 36 0 36 0 -17.7 0 -17.5 -17.9 02/23/2005 01:50:00 10.5 1 13 7.6 10.2 1 12.6 7.6 0.4 0 0.4 0.4 37 5 38 305 36 0 36 0 -17.7 0 -17.3 -17.9 02/23/2005 02:00:00 10.9 1.1 13.3 8 10.7 1.1 13.7 8 0.4 0 0.4 0.4 40 5 32 305 36 0 36 0 -17.7 0 -17.5 -17.9 02/23/2005 02:10:00 10.7 0.9 13.3 8.4 10.5 0.9 12.6 8.4 0.4 0 0.4 0.4 40 5 41 305 36 0 36 0 -17.6 0 -17.5 -17.9 02/23/2005 02:20:00 9.5 1 12.2 7.2 9.2 1.1 12.2 6.8 0.4 0 0.4 0.4 39 6 37 305 37 0 36 0 -17.7 0 -17.5 -18.1 02/23/2005 02:30:00 10.1 1.1 12.2 7.2 9.9 1.1 12.6 6.8 0.4 0 0.4 0.4 39 6 36 305 36 0 36 0 -17.8 0 -17.5 -18.1 02/23/2005 02:40:00 9.6 1 12.2 6.8 9.3 1 11.8 6.5 0.4 0 0.4 0.4 41 6 35 305 36 0 36 0 -17.8 0.1 -17.5 -18.1 02/23/2005 02:50:00 11 1.2 14.1 8.4 10.7 1.3 14.1 8 0.4 0 0.4 0.4 44 6 53 305 36 0 36 0 -17.7 0.1 -17.5 -18.1 02/23/2005 03:00:00 12.1 1.1 15.3 9.5 11.9 1.1 15.3 9.1 0.4 0 0.4 0.4 42 5 48 305 36 0 36 0 -17.6 0 -17.3 -17.9 02/23/2005 03:10:00 12.3 1.2 14.9 9.1 11.9 1.2 14.9 9.1 0.4 0 0.4 0.4 43 5 43 305 36 0 36 0 -17.8 0.1 -17.5 -18.1 02/23/2005 03:20:00 11.1 1 14.1 8.8 10.9 1 13 8.8 0.4 0 0.4 0.4 43 5 43 305 36 0 36 0 -17.8 0 -17.5 -18.1 02/23/2005 03:30:00 10.3 0.9 13 8 10 1 13.3 8 0.4 0 0.4 0.4 36 6 42 305 36 0 36 0 -17.8 0.1 -17.5 -18.1 02/23/2005 03:40:00 9.6 1.3 12.6 7.2 9.3 1.3 12.2 6.5 0.4 0 0.4 0.4 31 5 31 305 36 0 36 0 -17.9 0.1 -17.5 -18.1 02/23/2005 03:50:00 8.3 0.7 9.9 6.1 8.1 0.7 9.9 6.1 0.4 0 0.4 0.4 25 4 27 305 35 0 35 0 -18.1 0 -18.1 -18.2 02/23/2005 04:00:00 8.5 0.9 10.3 6.5 8.2 0.9 10.7 6.1 0.4 0 0.4 0.4 26 5 26 305 35 0 35 0 -18.2 0 -18.1 -18.4 02/23/2005 04:10:00 8.5 0.7 10.3 6.8 8.2 0.7 9.9 6.8 0.4 0 0.4 0.4 34 6 44 305 35 0 34 0 -18.1 0 -17.7 -18.4 02/23/2005 04:20:00 9.7 1.2 12.6 6.8 9.5 1.3 12.6 6.8 0.4 0 0.4 0.4 41 5 46 305 35 0 35 0 -18 0 -17.7 -18.2 02/23/2005 04:30:00 10.8 1.1 13.3 8.4 10.5 1.1 13.3 8 0.4 0 0.4 0.4 38 6 46 305 35 0 35 0 -17.9 0.1 -17.5 -18.1 02/23/2005 04:40:00 11.1 1 13.7 8.8 10.7 1 13.3 8.4 0.4 0 0.4 0.4 39 5 41 305 35 0 35 0 -17.9 0 -17.5 -18.1 02/23/2005 04:50:00 10.3 0.9 13.7 8.4 10 0.9 12.6 7.6 0.4 0 0.4 0.4 39 5 40 305 35 0 35 0 -18 0 -17.7 -18.1 02/23/2005 05:00:00 10.9 1.4 14.5 8 10.6 1.4 14.1 8 0.4 0 0.4 0.4 38 6 42 305 35 0 35 0 -17.9 0 -17.7 -18.1 02/23/2005 05:10:00 12.3 1.3 15.6 9.1 12 1.2 14.9 8.8 0.4 0 0.4 0.4 36 6 30 305 35 0 35 0 -17.9 0.1 -17.5 -18.1 02/23/2005 05:20:00 11.8 1 14.5 9.5 11.4 1 14.1 8.8 0.4 0 0.4 0.4 36 5 36 305 35 0 35 0 -17.9 0 -17.7 -18.1 02/23/2005 05:30:00 10.8 1 13 8 10.5 1 13 7.6 0.4 0 0.4 0.4 36 5 41 305 35 0 35 0 -18 0 -17.7 -18.1 02/23/2005 05:40:00 10.3 1 12.2 7.6 10.2 1 12.2 7.2 0.4 0 0.4 0.4 32 4 32 305 35 0 35 0 -18 0 -17.7 -18.1 02/23/2005 05:50:00 9.8 0.9 11.8 7.6 9.5 1 11.5 7.2 0.4 0 0.4 0.4 34 4 32 305 35 0 35 0 -18.1 0 -18.1 -18.4 02/23/2005 06:00:00 10.1 0.8 11.8 8 9.9 0.8 11.8 7.6 0.4 0 0.4 0.4 35 5 44 305 35 0 35 0 -18.1 0 -18.1 -18.4 02/23/2005 06:10:00 10.4 0.8 12.6 8 10.1 0.8 12.2 8.4 0.4 0 0.4 0.4 37 5 30 305 35 0 34 0 -18.1 0 -17.9 -18.2 02/23/2005 06:20:00 11.1 1.1 13.7 8 11 1.1 13.3 8 0.4 0 0.4 0.4 38 5 37 305 35 0 34 0 -18 0 -17.7 -18.1 02/23/2005 06:30:00 10.8 1.2 13.3 8 10.6 1.2 13.7 7.2 0.4 0 0.4 0.4 38 6 37 305 35 0 35 0 -17.9 0 -17.7 -18.1 02/23/2005 06:40:00 10 1 13 7.6 9.8 1 12.6 7.2 0.4 0 0.4 0.4 37 5 35 305 35 0 35 0 -18 0 -17.7 -18.1 02/23/2005 06:50:00 9.2 1.2 12.6 6.8 8.9 1.2 12.2 6.5 0.4 0 0.4 0.4 29 6 41 305 35 0 35 0 -18 0 -17.7 -18.2 02/23/2005 07:00:00 9.1 0.6 10.7 7.6 8.8 0.6 11.1 6.8 0.4 0 0.4 0.4 28 5 32 305 34 0 34 0 -18.2 0 -17.9 -18.4 02/23/2005 07:10:00 8.5 0.7 10.3 6.8 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 31 4 35 305 34 0 34 0 -18.2 0 -18.1 -18.4 02/23/2005 07:20:00 8.9 0.6 10.7 7.6 8.6 0.6 10.7 7.2 0.4 0 0.4 0.4 34 5 37 305 34 0 34 0 -18.2 0 -18.1 -18.4 02/23/2005 07:30:00 8.3 0.7 10.3 6.8 8 0.7 9.9 6.1 0.4 0 0.4 0.4 33 5 35 305 34 0 34 0 -18.2 0 -18.1 -18.4 02/23/2005 07:40:00 8.2 0.6 9.9 6.5 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 33 4 32 305 34 0 34 0 -18.2 0 -18.1 -18.4 02/23/2005 07:50:00 7.8 0.8 9.5 5.7 7.6 0.8 9.5 5.7 0.4 0 0.4 0.4 29 5 42 305 33 0 34 0 -18.1 0.1 -17.9 -18.4 02/23/2005 08:00:00 7.6 0.7 9.5 5.7 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 25 4 24 305 33 0 33 0 -18.4 0.1 -18.1 -18.4 02/23/2005 08:10:00 8.3 0.6 9.9 6.8 8.1 0.7 9.5 6.1 0.4 0 0.4 0.4 25 4 35 305 33 0 33 0 -18.4 0.1 -18.1 -18.4 02/23/2005 08:20:00 7.4 0.6 8.8 6.1 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 28 4 30 305 33 0 33 0 -18.5 0 -18.2 -18.6 02/23/2005 08:30:00 7.4 0.5 8.8 6.1 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 29 5 34 305 33 0 33 0 -18.5 0 -18.2 -18.6 02/23/2005 08:40:00 8.3 0.8 10.3 6.5 8 0.9 9.9 6.1 0.4 0 0.4 0.4 31 5 31 305 33 0 33 0 -18.5 0 -18.2 -18.6 02/23/2005 08:50:00 8.4 0.5 9.9 7.2 8.1 0.6 9.5 6.1 0.4 0 0.4 0.4 35 5 36 305 33 0 33 0 -18.5 0 -18.1 -18.6 02/23/2005 09:00:00 8.5 0.7 10.3 6.5 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 34 5 34 305 33 0 33 0 -18.4 0.1 -18.1 -18.4 02/23/2005 09:10:00 8.2 0.7 9.9 6.5 7.9 0.6 9.9 6.5 0.4 0 0.4 0.4 33 5 28 305 33 0 33 0 -18.3 0 -18.1 -18.4 02/23/2005 09:20:00 8.5 0.7 9.9 6.1 8.1 0.8 10.3 6.1 0.4 0 0.4 0.4 33 4 27 305 33 0 33 0 -18.3 0 -18.1 -18.4 02/23/2005 09:30:00 8.8 0.6 10.3 7.2 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 35 4 38 305 33 0 33 0 -18.3 0 -18.1 -18.4 02/23/2005 09:40:00 9.7 0.8 11.5 7.6 9.4 0.8 11.5 7.6 0.4 0 0.4 0.4 32 4 33 305 33 0 33 0 -18.3 0 -18.1 -18.4 02/23/2005 09:50:00 10.3 0.7 11.8 8.8 10.1 0.7 11.8 8.4 0.4 0 0.4 0.4 32 3 30 305 33 0 33 0 -18.2 0 -18.1 -18.4 02/23/2005 10:00:00 10.3 0.9 11.8 7.6 10 0.9 11.8 6.8 0.4 0 0.4 0.4 34 4 29 305 33 0 33 0 -18.2 0 -18.1 -18.4 02/23/2005 10:10:00 9.6 0.6 11.5 8 9.4 0.6 10.7 7.6 0.4 0 0.4 0.4 38 4 37 305 34 0 33 0 -18.2 0 -17.9 -18.4 02/23/2005 10:20:00 9.6 0.7 11.8 8 9.4 0.8 11.1 7.2 0.4 0 0.4 0.4 34 4 29 305 34 0 34 0 -18.1 0 -17.9 -18.4 02/23/2005 10:30:00 9.5 0.6 11.1 8 9.3 0.6 10.7 7.2 0.4 0 0.4 0.4 33 4 36 305 34 0 34 0 -18.1 0 -17.9 -18.2 02/23/2005 10:40:00 10.4 0.6 12.6 9.1 10.3 0.7 12.2 8.4 0.4 0 0.4 0.4 37 4 44 305 35 0 35 0 -17.9 0 -17.5 -18.1 02/23/2005 10:50:00 11 0.7 13 9.5 10.9 0.7 12.6 9.1 0.4 0 0.4 0.4 38 4 34 305 36 0 36 0 -17.8 0 -17.5 -17.9 02/23/2005 11:00:00 11.2 0.7 12.6 9.5 11.1 0.7 12.6 8.8 0.4 0 0.4 0.4 39 4 45 305 37 0 37 0 -17.7 0 -17.3 -17.9 02/23/2005 11:10:00 11.4 0.7 13 9.1 11.3 0.8 13 8.8 0.4 0 0.4 0.4 41 4 46 305 38 0 38 0 -17.7 0 -17.3 -17.9 02/23/2005 11:20:00 11.5 0.6 13 10.3 11.5 0.6 13.3 9.5 0.4 0 0.4 0.4 43 3 43 305 38 0 38 0 -17.6 0 -17.3 -17.9 02/23/2005 11:30:00 11.8 0.7 13.3 9.5 11.7 0.8 13.3 9.1 0.4 0 0.4 0.4 42 4 39 305 39 0 39 0 -17.6 0 -17.3 -17.7 02/23/2005 11:40:00 11.2 0.6 13 9.5 11.1 0.7 13 9.1 0.4 0 0.4 0.4 40 4 37 305 39 0 39 0 -17.5 0 -17.1 -17.7 02/23/2005 11:50:00 10.7 0.9 13 8.8 10.5 1 13.3 8.4 0.4 0 0.4 0.4 43 4 42 305 40 0 40 0 -17.5 0 -17.1 -17.7 02/23/2005 12:00:00 10.7 0.7 12.2 8.8 10.5 0.7 11.8 8.8 0.4 0 0.4 0.4 39 3 38 305 42 1 41 0 -17.4 0.1 -16.9 -17.5 02/23/2005 12:10:00 10.6 0.5 11.8 8.8 10.4 0.6 12.2 8.8 0.4 0 0.4 0.4 39 4 38 305 46 1 44 0 -17.3 0.1 -16.9 -17.5 02/23/2005 12:20:00 10.9 0.6 12.6 9.5 10.7 0.7 12.2 8.8 0.4 0 0.4 0.4 41 3 44 305 48 1 49 0 -17.2 0 -16.9 -17.3 02/23/2005 12:30:00 11.3 0.8 13 9.1 11 0.9 13.3 8.8 0.4 0 0.4 0.4 43 4 54 305 50 0 50 0 -16.9 0 -16.4 -17.1 02/23/2005 12:40:00 11 0.8 13.3 8.8 10.8 1 13.3 8.8 0.4 0 0.4 0.4 44 5 50 305 51 0 51 0 -16.8 0.1 -16.4 -16.9 02/23/2005 12:50:00 10.4 0.8 12.6 8.4 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 40 5 49 305 50 0 50 0 -16.5 0.1 -16 -16.7 02/23/2005 13:00:00 10.8 1 12.6 8 10.5 1.1 12.6 7.6 0.4 0 0.4 0.4 39 4 41 305 49 0 50 0 -16.4 0.1 -16 -16.6 02/23/2005 13:10:00 8.4 0.8 10.3 6.1 8.2 0.8 10.3 6.5 0.4 0 0.4 0.4 42 5 36 305 49 0 49 0 -16.4 0 -16 -16.6 02/23/2005 13:20:00 8.4 0.8 10.7 6.5 8.3 0.9 10.3 6.5 0.4 0 0.4 0.4 37 5 40 305 49 0 48 0 -16.3 0.1 -15.8 -16.4 02/23/2005 13:30:00 9.1 0.7 10.3 7.6 9 0.8 10.3 7.2 0.4 0 0.4 0.4 40 4 39 305 50 0 50 0 -16.1 0.1 -15.6 -16.2 02/23/2005 13:40:00 9.8 0.7 11.1 7.6 9.8 0.7 11.1 7.2 0.4 0 0.4 0.4 36 4 39 305 51 0 51 0 -15.9 0 -15.6 -16.2 02/23/2005 13:50:00 9.6 0.6 11.1 8 9.5 0.6 11.1 8 0.4 0 0.4 0.4 39 4 41 305 52 0 52 0 -15.8 0.1 -15.2 -16 02/23/2005 14:00:00 10.6 1.2 13.7 8.4 10.5 1.2 13.3 8 0.4 0 0.4 0.4 46 5 46 305 52 0 52 0 -15.8 0.1 -15.2 -16 02/23/2005 14:10:00 11.3 1 13.3 8.8 11.1 1 13.3 8.8 0.4 0 0.4 0.4 43 5 33 305 52 0 52 0 -15.8 0 -15.2 -16 02/23/2005 14:20:00 11.8 0.8 13.7 9.1 11.6 0.9 13.7 8.8 0.4 0 0.4 0.4 43 5 51 305 52 0 52 0 -15.8 0 -15.2 -16 02/23/2005 14:30:00 11.7 0.8 13.7 9.5 11.6 0.8 13.7 8.8 0.4 0 0.4 0.4 42 5 42 305 53 0 53 0 -15.8 0 -15.2 -15.8 02/23/2005 14:40:00 10.8 0.9 13 8.4 10.6 0.9 12.6 8 0.4 0 0.4 0.4 44 5 44 305 52 0 52 0 -15.7 0.1 -15.2 -15.8 02/23/2005 14:50:00 11 0.9 13 8.8 10.7 1 13 8.4 0.4 0 0.4 0.4 39 5 39 305 52 0 52 0 -15.6 0.1 -15 -15.8 02/23/2005 15:00:00 9.7 0.7 11.8 7.6 9.4 0.7 11.5 7.6 0.4 0 0.4 0.4 41 5 42 305 54 0 54 0 -15.5 0 -15 -15.6 02/23/2005 15:10:00 10.8 1 13 8 10.5 1 13 8 0.4 0 0.4 0.4 43 5 41 305 55 0 55 0 -15.5 0 -15 -15.6 02/23/2005 15:20:00 11.3 1 13.3 8.4 11.1 1 13.3 8.8 0.4 0 0.4 0.4 43 5 46 305 55 0 55 0 -15.6 0.1 -15 -15.8 02/23/2005 15:30:00 11.8 1 14.5 9.5 11.6 1 14.5 9.1 0.4 0 0.4 0.4 42 5 41 305 55 0 55 0 -15.6 0 -15 -15.8 02/23/2005 15:40:00 11.7 1.1 14.1 8.4 11.4 1.1 13.7 8 0.4 0 0.4 0.4 41 5 38 305 55 0 55 0 -15.5 0 -15 -15.6 02/23/2005 15:50:00 11.6 0.8 13 9.1 11.4 0.8 13.3 9.1 0.4 0 0.4 0.4 43 4 45 305 55 0 55 0 -15.5 0 -15 -15.6 02/23/2005 16:00:00 11.6 0.6 13 9.5 11.2 0.7 13 9.1 0.4 0 0.4 0.4 43 4 46 305 54 0 54 0 -15.5 0 -15 -15.6 02/23/2005 16:10:00 10.8 0.7 12.6 8.8 10.5 0.8 12.6 8.4 0.4 0 0.4 0.4 41 5 41 305 54 0 55 0 -15.5 0.1 -15 -15.6 02/23/2005 16:20:00 10.1 0.8 12.2 8 9.8 1 12.2 7.6 0.4 0 0.4 0.4 43 6 56 305 55 0 55 0 -15.4 0 -15 -15.6 02/23/2005 16:30:00 9.8 0.7 11.5 8 9.4 0.7 11.5 7.6 0.4 0 0.4 0.4 44 4 34 305 56 0 55 0 -15.4 0 -15 -15.6 02/23/2005 16:40:00 9.8 0.8 11.8 7.6 9.6 0.9 11.8 7.6 0.4 0 0.4 0.4 45 4 45 305 55 0 55 0 -15.3 0 -14.8 -15.6 02/23/2005 16:50:00 10.2 0.6 11.8 8.8 10 0.6 11.8 8.4 0.4 0 0.4 0.4 44 4 43 305 55 0 55 0 -15.3 0 -14.8 -15.6 02/23/2005 17:00:00 10.2 0.9 12.6 7.2 10 0.9 12.6 7.6 0.4 0 0.4 0.4 43 5 46 305 55 0 55 0 -15.2 0 -14.6 -15.4 02/23/2005 17:10:00 11 0.8 12.6 8.4 10.7 0.8 12.2 8.4 0.4 0 0.4 0.4 44 5 41 305 55 0 55 0 -15.2 0.1 -14.6 -15.2 02/23/2005 17:20:00 11.6 1 13.7 9.1 11.3 1 13.7 8.8 0.4 0 0.4 0.4 38 5 37 305 55 0 55 0 -15.1 0.1 -14.6 -15.2 02/23/2005 17:30:00 10.9 1 13.3 8.4 10.6 1 13.7 7.6 0.4 0 0.4 0.4 39 4 39 305 56 0 56 0 -15.1 0.1 -14.6 -15.2 02/23/2005 17:40:00 11.1 1.1 13.7 8.8 10.9 1.1 13.7 8.8 0.4 0 0.4 0.4 40 5 40 305 55 0 55 0 -15.1 0.1 -14.6 -15.2 02/23/2005 17:50:00 10.6 1 13 8 10.3 1 12.6 8 0.4 0 0.4 0.4 39 5 38 305 55 0 55 0 -14.9 0 -14.4 -15.2 02/23/2005 18:00:00 11.6 1.1 14.1 9.1 11.3 1.2 13.7 8.4 0.4 0 0.4 0.4 42 5 45 305 55 0 54 0 -14.8 0.1 -14.4 -15 02/23/2005 18:10:00 12.1 1 14.1 9.5 11.7 1 14.1 9.5 0.4 0 0.4 0.4 44 5 51 305 54 0 54 0 -15 0 -14.4 -15 02/23/2005 18:20:00 11.9 0.9 14.1 9.9 11.7 1 13.7 9.1 0.4 0 0.4 0.4 41 4 44 305 53 0 53 0 -15 0 -14.6 -15 02/23/2005 18:30:00 11.1 0.8 13 8.8 10.9 0.9 13.3 8 0.4 0 0.4 0.4 43 5 44 305 53 0 53 0 -15 0 -14.6 -15 02/23/2005 18:40:00 11.5 1.1 13.7 9.1 11.2 1.1 13.3 8.8 0.4 0 0.4 0.4 42 5 38 305 52 0 52 0 -15 0 -14.6 -15 02/23/2005 18:50:00 11.4 1.2 13.7 8.8 11.1 1.2 13.7 8.4 0.4 0 0.4 0.4 45 4 49 305 52 0 52 0 -14.9 0 -14.4 -15 02/23/2005 19:00:00 10.9 0.7 12.2 8.4 10.7 0.8 12.6 8.4 0.4 0 0.4 0.4 45 4 41 305 52 0 52 0 -14.9 0.1 -14.4 -15 02/23/2005 19:10:00 10.3 0.8 11.8 8.4 10 0.8 12.2 7.6 0.4 0 0.4 0.4 45 4 43 305 52 0 52 0 -14.9 0.1 -14.4 -15 02/23/2005 19:20:00 11.4 0.9 13.7 8.8 11.1 1 13.3 8.8 0.4 0 0.4 0.4 42 5 38 305 51 0 51 0 -14.9 0 -14.4 -15 02/23/2005 19:30:00 11.2 1 13.7 9.1 10.9 1 13.7 8.4 0.4 0 0.4 0.4 44 5 44 305 51 0 51 0 -15 0 -14.6 -15 02/23/2005 19:40:00 11 0.8 13.3 9.1 10.6 0.9 13 8.4 0.4 0 0.4 0.4 43 4 46 305 51 0 51 0 -15.1 0.1 -14.6 -15.2 02/23/2005 19:50:00 11 0.7 12.6 9.1 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 43 4 43 305 50 0 50 0 -15.1 0.1 -14.6 -15.2 02/23/2005 20:00:00 10.9 0.8 13 8.8 10.5 0.8 12.6 8.4 0.4 0 0.4 0.4 44 5 42 305 50 0 50 0 -15.1 0.1 -14.6 -15.2 02/23/2005 20:10:00 12.6 1.3 15.6 9.1 12.3 1.5 15.6 8.8 0.4 0 0.4 0.4 44 4 48 305 49 0 49 0 -15 0.1 -14.6 -15.2 02/23/2005 20:20:00 12.4 1 15.3 9.9 12.1 1.2 15.3 9.1 0.4 0 0.4 0.4 47 5 46 305 49 0 50 0 -14.9 0.1 -14.4 -15 02/23/2005 20:30:00 12.7 1 14.9 10.3 12.4 1 14.9 9.5 0.4 0 0.4 0.4 47 4 46 305 49 0 49 0 -15.1 0.1 -14.6 -15.2 02/23/2005 20:40:00 13.4 0.9 15.6 11.1 13.1 1 15.6 10.3 0.4 0 0.4 0.4 49 4 50 305 49 0 49 0 -15.2 0.1 -14.6 -15.4 02/23/2005 20:50:00 12.5 0.9 14.5 10.3 12.1 1 14.5 9.5 0.4 0 0.4 0.4 49 4 50 305 49 0 49 0 -15.3 0 -14.8 -15.4 02/23/2005 21:00:00 12.5 0.8 14.5 9.9 12.2 0.9 14.1 9.5 0.4 0 0.4 0.4 49 4 48 305 48 0 48 0 -15.3 0 -14.8 -15.6 02/23/2005 21:10:00 12.4 0.8 14.1 10.3 12.1 0.9 14.1 9.5 0.4 0 0.4 0.4 49 5 54 305 48 0 48 0 -15.4 0 -15 -15.6 02/23/2005 21:20:00 12.1 0.9 14.1 9.5 11.7 0.9 13.7 9.1 0.4 0 0.4 0.4 50 4 52 305 48 0 48 0 -15.4 0 -15 -15.6 02/23/2005 21:30:00 11.9 0.7 14.1 10.3 11.6 0.8 13.7 9.5 0.4 0 0.4 0.4 50 5 48 305 48 0 48 0 -15.4 0 -14.8 -15.6 02/23/2005 21:40:00 12.1 0.9 15.6 9.9 11.7 1 14.9 9.1 0.4 0 0.4 0.4 49 5 46 305 48 0 48 0 -15.3 0 -15 -15.6 02/23/2005 21:50:00 12.6 0.8 14.9 10.3 12.4 1 14.9 9.9 0.4 0 0.4 0.4 47 4 50 305 48 0 48 0 -15.2 0 -14.6 -15.4 02/23/2005 22:00:00 12.8 0.7 14.5 11.1 12.5 0.9 14.5 10.3 0.4 0 0.4 0.4 48 4 56 305 48 0 48 0 -15.2 0.1 -14.6 -15.2 02/23/2005 22:10:00 11.6 1.1 15.3 9.1 11.4 1.2 14.9 8.4 0.4 0 0.4 0.4 49 5 47 305 48 0 48 0 -15.2 0 -14.8 -15.2 02/23/2005 22:20:00 12.5 1.1 15.3 9.9 12.2 1.2 15.6 9.5 0.4 0 0.4 0.4 48 5 54 305 48 0 48 0 -15.3 0 -14.8 -15.4 02/23/2005 22:30:00 11.3 1 14.5 8.8 11 1.1 15.3 8.8 0.4 0 0.4 0.4 49 7 50 305 48 0 48 0 -15.4 0.1 -15 -15.6 02/23/2005 22:40:00 11.2 0.8 13 8.4 10.9 0.8 13 8.4 0.4 0 0.4 0.4 49 4 54 305 47 0 47 0 -15.5 0 -15 -15.6 02/23/2005 22:50:00 10.4 0.8 12.6 8 10 0.9 12.6 6.8 0.4 0 0.4 0.4 46 5 42 305 47 0 47 0 -15.5 0.1 -15 -15.6 02/23/2005 23:00:00 10.6 0.9 13 7.6 10.4 1 12.6 8 0.4 0 0.4 0.4 42 5 45 305 47 0 47 0 -15.5 0.1 -15 -15.6 02/23/2005 23:10:00 9.6 0.9 11.5 8 9.3 1 11.5 7.2 0.4 0 0.4 0.4 44 4 44 305 47 0 47 0 -15.6 0.1 -15 -15.8 02/23/2005 23:20:00 8.6 1 11.1 6.5 8.3 1 10.7 6.5 0.4 0 0.4 0.4 50 7 57 305 47 0 46 0 -15.8 0.1 -15.2 -16 02/23/2005 23:30:00 9.9 0.8 11.8 8 9.7 0.8 11.8 7.6 0.4 0 0.4 0.4 52 5 53 305 45 0 45 0 -16.1 0 -15.6 -16.4 02/23/2005 23:40:00 9.9 0.6 11.5 8 9.6 0.7 11.5 7.6 0.4 0 0.4 0.4 49 5 49 305 44 0 45 0 -16.2 0.1 -15.8 -16.4 02/23/2005 23:50:00 9.8 0.8 11.8 8 9.5 0.9 11.8 7.6 0.4 0 0.4 0.4 43 6 32 305 44 0 44 0 -16.3 0 -15.8 -16.4 02/24/2005 00:00:00 9 0.7 10.7 7.2 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 47 5 48 305 44 0 43 0 -16.4 0.1 -16 -16.7 02/24/2005 00:10:00 10.1 1 11.8 8 9.9 1 12.2 8 0.4 0 0.4 0.4 46 4 48 305 43 0 43 0 -16.6 0 -16.2 -16.7 02/24/2005 00:20:00 10.5 0.7 11.8 8.8 10.3 0.7 11.8 8.4 0.4 0 0.4 0.4 40 5 42 305 43 0 43 0 -16.6 0 -16.2 -16.7 02/24/2005 00:30:00 10.4 0.6 12.2 8.8 10.1 0.7 12.2 8.4 0.4 0 0.4 0.4 40 4 43 305 42 0 42 0 -16.6 0 -16.4 -16.9 02/24/2005 00:40:00 10.5 0.8 12.2 8 10.3 0.8 12.2 7.6 0.4 0 0.4 0.4 41 5 46 305 42 0 42 0 -16.7 0.1 -16.4 -16.9 02/24/2005 00:50:00 10.6 0.7 12.2 8.4 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 41 6 32 305 42 0 42 0 -16.8 0 -16.4 -16.9 02/24/2005 01:00:00 10.3 0.9 12.6 8.4 10 1 12.2 7.6 0.4 0 0.4 0.4 44 4 41 305 41 0 41 0 -16.9 0 -16.6 -16.9 02/24/2005 01:10:00 10.3 0.8 12.2 8.8 10.1 0.8 12.2 8.4 0.4 0 0.4 0.4 43 4 42 305 41 0 41 0 -16.9 0 -16.6 -16.9 02/24/2005 01:20:00 10.1 0.8 11.8 8 9.8 0.8 11.8 7.6 0.4 0 0.4 0.4 44 4 45 305 40 0 40 0 -17.1 0.1 -16.9 -17.3 02/24/2005 01:30:00 10.6 0.5 11.8 8.8 10.3 0.6 11.8 8 0.4 0 0.4 0.4 50 3 52 305 39 0 40 0 -17.4 0 -16.9 -17.5 02/24/2005 01:40:00 10.3 0.5 11.5 8.8 9.9 0.6 11.5 8.4 0.4 0 0.4 0.4 49 3 47 305 39 0 39 0 -17.4 0 -17.1 -17.5 02/24/2005 01:50:00 9.6 0.7 11.1 8 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 48 3 48 305 38 0 38 0 -17.5 0 -17.3 -17.5 02/24/2005 02:00:00 8.5 0.5 9.5 6.8 8.2 0.6 9.5 6.1 0.4 0 0.4 0.4 49 4 48 305 38 0 38 0 -17.5 0 -17.1 -17.7 02/24/2005 02:10:00 8.8 0.9 11.5 7.2 8.5 0.8 10.7 6.5 0.4 0 0.4 0.4 40 6 36 305 38 0 38 0 -17.5 0 -17.3 -17.5 02/24/2005 02:20:00 8.7 0.6 10.3 6.8 8.5 0.6 9.9 6.5 0.4 0 0.4 0.4 43 4 47 305 38 0 38 0 -17.5 0 -17.3 -17.7 02/24/2005 02:30:00 9.5 1 12.6 7.2 9.2 1 11.8 7.2 0.4 0 0.4 0.4 40 5 32 305 37 0 38 0 -17.5 0 -17.5 -17.7 02/24/2005 02:40:00 10.9 0.9 12.6 8.4 10.6 0.9 12.6 8 0.4 0 0.4 0.4 39 4 37 305 37 0 37 0 -17.5 0 -17.1 -17.7 02/24/2005 02:50:00 10.1 0.7 11.8 8.4 9.9 0.7 11.8 8.4 0.4 0 0.4 0.4 42 4 42 305 37 0 36 0 -17.7 0 -17.5 -17.9 02/24/2005 03:00:00 9.7 0.8 12.6 7.6 9.4 0.9 12.2 7.2 0.4 0 0.4 0.4 39 5 39 305 37 0 37 0 -17.8 0 -17.5 -17.9 02/24/2005 03:10:00 9.7 0.8 11.8 7.6 9.4 0.9 11.5 7.2 0.4 0 0.4 0.4 39 5 30 305 36 0 36 0 -17.8 0 -17.5 -17.9 02/24/2005 03:20:00 9 1 11.8 7.2 8.8 1 11.1 6.8 0.4 0 0.4 0.4 40 6 36 305 36 0 36 0 -17.8 0 -17.5 -18.1 02/24/2005 03:30:00 8.2 0.6 9.5 6.5 7.9 0.7 9.1 6.1 0.4 0 0.4 0.4 45 4 49 305 36 0 36 0 -18 0 -17.9 -18.1 02/24/2005 03:40:00 8 0.9 9.9 5.7 7.6 0.9 9.9 5.3 0.4 0 0.4 0.4 42 7 45 305 36 0 36 0 -18 0 -17.9 -18.1 02/24/2005 03:50:00 8.6 0.8 10.3 6.1 8.2 0.9 10.3 5.7 0.4 0 0.4 0.4 38 6 41 305 36 0 35 0 -18.1 0 -18.1 -18.1 02/24/2005 04:00:00 8 0.9 10.3 5.7 7.8 1 9.9 5.7 0.4 0 0.4 0.4 36 5 32 305 35 0 35 0 -18 0 -17.9 -18.1 02/24/2005 04:10:00 8.2 0.9 10.3 6.1 8 1 9.9 5.7 0.4 0 0.4 0.4 37 5 39 305 35 0 35 0 -18.1 0 -17.9 -18.4 02/24/2005 04:20:00 7.9 1 9.9 5.7 7.6 1 9.5 5.3 0.4 0 0.4 0.4 39 6 36 305 35 0 35 0 -18.2 0 -18.1 -18.4 02/24/2005 04:30:00 7.6 0.8 9.5 5.7 7.3 0.8 9.1 5.7 0.4 0 0.4 0.4 40 7 43 305 35 0 34 0 -18.2 0 -18.1 -18.4 02/24/2005 04:40:00 8.3 0.7 9.9 6.1 8 0.8 9.9 6.1 0.4 0 0.4 0.4 44 5 42 305 34 0 34 0 -18.4 0.1 -18.1 -18.4 02/24/2005 04:50:00 9.3 0.8 11.5 7.2 9 0.9 11.1 6.8 0.4 0 0.4 0.4 45 4 48 305 34 0 34 0 -18.4 0 -18.1 -18.4 02/24/2005 05:00:00 10.1 0.6 11.5 8 9.8 0.7 11.1 8 0.4 0 0.4 0.4 46 4 51 305 34 0 34 0 -18.4 0.1 -18.1 -18.4 02/24/2005 05:10:00 9.5 0.6 10.7 7.6 9.3 0.7 10.7 7.2 0.4 0 0.4 0.4 46 4 41 305 34 0 34 0 -18.5 0 -18.1 -18.4 02/24/2005 05:20:00 9 0.8 11.5 6.5 8.7 0.9 10.7 6.5 0.4 0 0.4 0.4 46 4 48 305 33 0 33 0 -18.5 0 -18.2 -18.6 02/24/2005 05:30:00 8.7 0.6 10.3 6.8 8.4 0.6 10.3 6.8 0.4 0 0.4 0.4 48 4 51 305 33 0 33 0 -18.5 0 -18.2 -18.6 02/24/2005 05:40:00 9.4 0.9 11.5 6.8 9.1 1 11.5 6.5 0.4 0 0.4 0.4 45 4 46 305 33 0 33 0 -18.5 0 -18.2 -18.6 02/24/2005 05:50:00 9.4 1 12.2 6.8 8.9 1 11.8 6.8 0.4 0 0.4 0.4 43 6 46 305 33 0 33 0 -18.6 0 -18.2 -18.8 02/24/2005 06:00:00 9.4 0.9 11.8 7.2 9.1 1 11.8 6.8 0.4 0 0.4 0.4 45 5 51 305 32 0 32 0 -18.6 0 -18.4 -18.8 02/24/2005 06:10:00 9.5 0.9 11.8 6.8 9.2 1 11.5 5.7 0.4 0 0.4 0.4 45 5 52 305 32 0 32 0 -18.6 0 -18.4 -18.8 02/24/2005 06:20:00 8.3 0.6 9.5 6.8 8.1 0.7 9.5 5.7 0.4 0 0.4 0.4 45 5 43 305 32 0 32 0 -18.7 0 -18.4 -18.8 02/24/2005 06:30:00 8.3 1 11.5 6.1 8 1 11.1 5.7 0.4 0 0.4 0.4 45 6 45 305 32 0 32 0 -18.7 0 -18.4 -18.8 02/24/2005 06:40:00 8.4 1 11.1 5.3 8.1 1.1 11.1 5.3 0.4 0 0.4 0.4 43 5 42 305 32 0 32 0 -18.7 0 -18.4 -18.8 02/24/2005 06:50:00 7.8 1 10.3 5.7 7.4 1 9.9 4.9 0.4 0 0.4 0.4 37 6 32 305 32 0 32 0 -18.7 0 -18.4 -18.8 02/24/2005 07:00:00 8.6 0.8 11.1 6.5 8.1 0.8 11.1 6.1 0.4 0 0.4 0.4 38 6 40 305 31 0 32 0 -18.7 0 -18.4 -18.8 02/24/2005 07:10:00 7.8 0.7 9.5 6.1 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 41 4 31 305 31 0 31 0 -18.8 0 -18.4 -19 02/24/2005 07:20:00 6.8 0.7 8.4 5.3 6.5 0.7 8 4.9 0.4 0 0.4 0.4 38 5 43 305 31 0 31 0 -18.8 0 -18.6 -19 02/24/2005 07:30:00 6.9 0.7 8.4 5.3 6.6 0.8 8.4 4.9 0.4 0 0.4 0.4 37 4 35 305 31 0 31 0 -18.9 0 -18.6 -19 02/24/2005 07:40:00 6.7 1.2 10.3 4.6 6.4 1.2 9.9 4.6 0.4 0 0.4 0.4 36 6 39 305 31 0 31 0 -19 0 -18.8 -19 02/24/2005 07:50:00 7.5 0.8 9.5 5.3 7.2 0.9 9.9 4.9 0.4 0 0.4 0.4 33 5 37 305 30 0 31 0 -19 0 -18.8 -19 02/24/2005 08:00:00 8.8 1 10.7 6.8 8.4 1 11.1 6.5 0.4 0 0.4 0.4 39 5 34 305 30 0 30 0 -19 0 -18.8 -19.2 02/24/2005 08:10:00 7.4 0.6 9.1 5.7 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 38 5 36 305 30 0 30 0 -19.1 0 -19 -19.2 02/24/2005 08:20:00 7.3 0.7 9.5 6.1 7 0.6 9.1 5.7 0.4 0 0.4 0.4 37 5 40 305 30 0 29 0 -19.1 0 -19 -19.2 02/24/2005 08:30:00 7.7 0.7 9.5 6.1 7.3 0.7 9.1 5.7 0.4 0 0.4 0.4 39 5 41 305 30 0 29 0 -19.1 0 -19 -19.2 02/24/2005 08:40:00 7 0.7 8.8 5.3 6.7 0.7 8.8 4.9 0.4 0 0.4 0.4 38 6 47 305 29 0 29 0 -19.1 0 -19 -19.2 02/24/2005 08:50:00 6.6 0.6 8.4 4.6 6.2 0.6 7.6 4.9 0.4 0 0.4 0.4 42 5 35 305 29 0 29 0 -19.1 0 -19 -19.2 02/24/2005 09:00:00 6.5 0.5 7.6 4.9 6.2 0.5 7.6 4.9 0.4 0 0.4 0.4 41 5 43 305 29 0 29 0 -19.2 0 -19 -19.3 02/24/2005 09:10:00 7.1 0.6 8.8 5.7 6.8 0.6 8.4 4.9 0.4 0 0.4 0.4 41 4 36 305 29 0 29 0 -19.1 0 -19 -19.2 02/24/2005 09:20:00 7.2 0.6 8.8 5.7 7 0.7 9.1 5.3 0.4 0 0.4 0.4 38 4 32 305 29 0 29 0 -19.1 0 -19 -19.3 02/24/2005 09:30:00 6.3 0.5 7.6 4.9 6 0.5 7.6 4.9 0.4 0 0.4 0.4 41 5 38 305 29 0 29 0 -19.1 0 -19 -19.3 02/24/2005 09:40:00 6.4 0.5 7.6 4.9 6.1 0.5 7.2 4.6 0.4 0 0.4 0.4 44 3 43 305 29 0 29 0 -19.2 0 -19 -19.5 02/24/2005 09:50:00 6.1 0.5 7.2 4.9 5.8 0.5 7.2 4.6 0.4 0 0.4 0.4 41 4 41 305 29 0 29 0 -19.3 0 -19 -19.5 02/24/2005 10:00:00 6.4 0.6 8 4.9 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 41 5 36 305 29 0 29 0 -19.2 0.1 -19 -19.5 02/24/2005 10:10:00 6.7 0.5 8 5.3 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 43 3 37 305 29 0 29 0 -19.2 0 -19 -19.3 02/24/2005 10:20:00 7 0.5 8 5.7 6.7 0.5 8 5.3 0.4 0 0.4 0.4 43 4 46 305 29 0 29 0 -19.3 0 -19 -19.5 02/24/2005 10:30:00 7.7 0.6 9.1 6.1 7.5 0.6 8.8 5.7 0.4 0 0.4 0.4 40 5 32 305 29 0 29 0 -19.2 0 -19 -19.3 02/24/2005 10:40:00 8.6 0.6 10.3 7.2 8.3 0.6 10.3 6.8 0.4 0 0.4 0.4 36 4 42 305 29 0 29 0 -19.1 0 -19 -19.3 02/24/2005 10:50:00 8.4 0.7 9.9 6.1 8.2 0.7 9.5 6.5 0.4 0 0.4 0.4 38 4 44 305 29 0 29 0 -19.2 0 -19 -19.3 02/24/2005 11:00:00 9.3 0.6 11.1 7.6 9.1 0.6 10.7 7.2 0.4 0 0.4 0.4 40 4 43 305 29 0 29 0 -19.2 0 -19 -19.3 02/24/2005 11:10:00 8.4 0.6 10.3 6.8 8.2 0.6 9.5 6.5 0.4 0 0.4 0.4 38 4 40 305 30 0 29 0 -19.2 0 -19 -19.3 02/24/2005 11:20:00 7.9 0.6 9.1 6.5 7.6 0.6 9.5 6.1 0.4 0 0.4 0.4 40 4 39 305 31 1 32 0 -19.1 0 -19 -19.2 02/24/2005 11:30:00 7.5 0.5 8.8 5.7 7.1 0.5 8.8 5.3 0.4 0 0.4 0.4 39 4 45 305 34 1 34 0 -19.1 0 -19 -19.2 02/24/2005 11:40:00 6.8 0.9 8.8 4.9 6.5 0.9 8.4 4.6 0.4 0 0.4 0.4 39 5 37 305 36 1 35 0 -19.1 0 -19 -19.2 02/24/2005 11:50:00 6.1 0.7 8 4.6 5.8 0.7 7.6 4.2 0.4 0 0.4 0.4 41 5 39 305 39 1 39 0 -19.1 0 -19 -19.2 02/24/2005 12:00:00 6.8 0.7 8.4 4.6 6.4 0.8 8 4.6 0.4 0 0.4 0.4 39 5 40 305 41 0 41 0 -18.9 0 -18.4 -19 02/24/2005 12:10:00 7.5 0.8 9.5 5.7 7.2 0.9 9.5 4.9 0.4 0 0.4 0.4 36 6 37 305 42 0 42 0 -18.9 0 -18.6 -19 02/24/2005 12:20:00 7.2 0.8 9.1 5.3 6.9 0.8 8.8 4.9 0.4 0 0.4 0.4 38 6 46 305 43 0 42 0 -18.7 0 -18.4 -18.8 02/24/2005 12:30:00 6.5 0.7 8.8 4.6 6.4 0.7 8.4 4.2 0.4 0 0.4 0.4 39 5 35 305 44 0 43 0 -18.7 0 -18.4 -19 02/24/2005 12:40:00 6.5 0.5 8 4.9 6.2 0.6 7.6 4.9 0.4 0 0.4 0.4 42 5 45 305 46 0 45 0 -18.7 0 -18.4 -19 02/24/2005 12:50:00 6.9 0.5 8 5.3 6.6 0.6 8 4.6 0.4 0 0.4 0.4 44 4 37 305 47 0 48 0 -18.7 0 -18.4 -18.8 02/24/2005 13:00:00 6.7 0.5 8 5.3 6.4 0.6 7.6 4.6 0.4 0 0.4 0.4 44 5 47 305 49 0 48 0 -18.6 0 -18.4 -18.8 02/24/2005 13:10:00 8.2 0.7 9.9 5.7 8 0.7 9.5 6.1 0.4 0 0.4 0.4 39 4 42 305 49 0 49 0 -18.6 0.1 -18.1 -18.8 02/24/2005 13:20:00 7.9 0.6 9.1 6.1 7.6 0.6 8.8 6.1 0.4 0 0.4 0.4 45 4 47 305 48 0 49 0 -18.4 0.1 -18.1 -18.6 02/24/2005 13:30:00 8.3 0.8 9.5 6.5 8 0.8 9.5 5.7 0.4 0 0.4 0.4 45 4 47 305 47 0 48 0 -18.5 0 -18.1 -18.6 02/24/2005 13:40:00 8.2 0.6 9.1 6.5 7.9 0.7 9.1 6.1 0.4 0 0.4 0.4 46 4 45 305 46 0 46 0 -18.4 0.1 -18.1 -18.4 02/24/2005 13:50:00 7.9 0.7 9.9 5.7 7.7 0.7 9.9 5.7 0.4 0 0.4 0.4 42 5 44 305 46 0 46 0 -18.2 0.1 -17.9 -18.4 02/24/2005 14:00:00 8.1 0.8 9.5 6.5 7.9 0.8 9.5 5.7 0.4 0 0.4 0.4 46 3 53 305 47 0 47 0 -18.2 0 -17.9 -18.4 02/24/2005 14:10:00 7.6 0.7 9.5 6.1 7.4 0.8 9.5 5.7 0.4 0 0.4 0.4 44 5 45 305 47 0 47 0 -18.1 0 -17.7 -18.4 02/24/2005 14:20:00 8.3 0.6 9.9 6.8 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 42 4 42 305 48 0 47 0 -18.1 0.1 -17.7 -18.2 02/24/2005 14:30:00 8.2 0.5 9.5 7.2 8 0.5 9.5 6.5 0.4 0 0.4 0.4 41 4 40 305 48 0 48 0 -18.1 0 -17.7 -18.2 02/24/2005 14:40:00 8.2 0.5 9.5 6.8 8 0.6 9.5 6.5 0.4 0 0.4 0.4 42 4 45 305 49 0 49 0 -18.1 0 -17.7 -18.2 02/24/2005 14:50:00 7.8 0.6 9.1 6.1 7.6 0.6 9.1 5.3 0.4 0 0.4 0.4 41 4 42 305 49 0 49 0 -18 0 -17.7 -18.2 02/24/2005 15:00:00 8 0.5 9.5 6.5 7.7 0.6 9.5 6.1 0.4 0 0.4 0.4 34 5 33 305 51 1 50 0 -18 0 -17.5 -18.1 02/24/2005 15:10:00 7.7 0.7 9.1 6.1 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 36 5 39 305 53 0 53 0 -18 0 -17.5 -18.1 02/24/2005 15:20:00 7.9 0.5 9.1 6.5 7.8 0.6 9.1 6.5 0.4 0 0.4 0.4 37 4 42 305 54 0 54 0 -18 0 -17.5 -18.1 02/24/2005 15:30:00 6.4 0.8 8.4 4.6 6.3 0.9 8 3.8 0.4 0 0.4 0.4 32 5 36 305 55 1 54 0 -17.9 0.1 -17.5 -18.1 02/24/2005 15:40:00 6.7 0.7 8.4 4.6 6.6 0.7 8.4 4.2 0.4 0 0.4 0.4 34 5 39 305 58 1 59 0 -17.8 0 -17.5 -18.1 02/24/2005 15:50:00 6.7 0.6 8 4.9 6.6 0.6 7.6 4.9 0.4 0 0.4 0.4 36 4 36 305 60 0 60 0 -17.9 0 -17.5 -18.1 02/24/2005 16:00:00 6.7 0.6 8 4.9 6.5 0.6 8 4.9 0.4 0 0.4 0.4 35 5 41 305 60 1 60 0 -17.8 0 -17.5 -18.1 02/24/2005 16:10:00 6.4 0.8 8 4.6 6.2 0.8 8 4.6 0.4 0 0.4 0.4 31 5 23 305 64 2 65 0 -17.8 0 -17.3 -18.1 02/24/2005 16:20:00 6.3 0.6 7.6 4.9 6.2 0.6 7.6 4.9 0.4 0 0.4 0.4 29 5 35 305 69 1 70 0 -17.8 0.1 -17.5 -18.1 02/24/2005 16:30:00 7.2 0.7 8.8 5.3 7.1 0.7 8.8 4.9 0.4 0 0.4 0.4 24 5 29 305 73 1 73 0 -18 0 -17.9 -18.2 02/24/2005 16:40:00 7.1 0.7 8.4 4.9 6.9 0.8 8.4 4.6 0.4 0 0.4 0.4 29 5 33 305 74 0 74 0 -18.1 0 -17.9 -18.2 02/24/2005 16:50:00 7.1 0.6 8.4 5.7 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 31 6 37 305 71 1 73 0 -18 0 -17.7 -18.2 02/24/2005 17:00:00 6.6 0.8 8.4 4.6 6.4 0.8 8 4.6 0.4 0 0.4 0.4 28 5 30 305 72 0 72 0 -18.1 0 -17.7 -18.2 02/24/2005 17:10:00 6.4 0.5 7.6 5.3 6.4 0.6 8 4.9 0.4 0 0.4 0.4 27 5 26 305 73 0 74 0 -18.1 0 -18.1 -18.4 02/24/2005 17:20:00 7.1 0.8 8.8 4.9 7 0.8 8.4 4.9 0.4 0 0.4 0.4 27 4 21 305 74 0 73 0 -18.2 0 -18.1 -18.4 02/24/2005 17:30:00 7 0.6 8.8 4.9 6.8 0.6 8.4 5.3 0.4 0 0.4 0.4 29 4 33 305 73 0 73 0 -18.3 0 -18.1 -18.4 02/24/2005 17:40:00 7.1 0.6 8.4 5.3 7 0.7 8.4 4.9 0.4 0 0.4 0.4 31 5 27 305 70 1 68 0 -18.3 0 -18.1 -18.4 02/24/2005 17:50:00 7.7 0.6 9.1 5.7 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 36 4 36 305 66 2 68 0 -18.4 0.1 -18.1 -18.4 02/24/2005 18:00:00 8.4 0.6 9.5 6.5 8.3 0.6 9.9 6.5 0.4 0 0.4 0.4 34 4 35 305 62 1 62 0 -18.5 0 -18.1 -18.6 02/24/2005 18:10:00 7.8 0.7 9.1 5.7 7.8 0.6 8.8 5.7 0.4 0 0.4 0.4 31 3 29 305 64 0 64 0 -18.6 0 -18.2 -18.8 02/24/2005 18:20:00 7.4 0.8 9.1 5.7 7.3 0.8 8.8 5.3 0.4 0 0.4 0.4 33 3 33 305 61 1 63 0 -18.6 0 -18.2 -18.8 02/24/2005 18:30:00 7.1 0.5 8.4 5.7 6.9 0.6 8 5.3 0.4 0 0.4 0.4 28 4 29 305 59 0 59 0 -18.7 0.1 -18.4 -19 02/24/2005 18:40:00 7 0.9 8.4 4.9 6.9 0.9 8.4 4.9 0.4 0 0.4 0.4 36 5 36 305 56 2 56 0 -18.8 0 -18.4 -19 02/24/2005 18:50:00 6.9 0.7 8.4 4.9 6.8 0.6 8.4 4.9 0.4 0 0.4 0.4 30 6 32 305 51 0 52 0 -18.9 0.1 -18.4 -19 02/24/2005 19:00:00 8.1 0.6 9.5 6.1 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 29 4 33 305 50 0 51 0 -19 0 -18.6 -19.2 02/24/2005 19:10:00 7.6 0.6 9.1 5.7 7.4 0.6 9.1 5.7 0.4 0 0.4 0.4 34 5 33 305 46 2 46 0 -19.2 0.1 -18.8 -19.5 02/24/2005 19:20:00 8.3 0.7 9.9 6.5 8.2 0.7 10.3 6.5 0.4 0 0.4 0.4 27 5 27 305 41 1 39 0 -19.4 0 -19 -19.5 02/24/2005 19:30:00 8.7 0.6 9.9 6.5 8.6 0.6 9.9 7.2 0.4 0 0.4 0.4 25 4 31 305 36 1 38 0 -19.4 0.1 -19 -19.5 02/24/2005 19:40:00 9.4 0.7 11.5 7.2 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 30 4 34 305 33 1 32 0 -19.5 0.1 -19.2 -19.5 02/24/2005 19:50:00 8 0.8 10.3 5.7 7.7 0.8 9.5 6.1 0.4 0 0.4 0.4 30 5 33 305 31 0 32 0 -19.5 0 -19.2 -19.7 02/24/2005 20:00:00 8.9 0.9 10.7 6.5 8.8 0.9 10.7 6.1 0.4 0 0.4 0.4 29 5 27 305 30 0 30 0 -19.5 0 -19.3 -19.5 02/24/2005 20:10:00 8.1 0.8 9.9 6.1 7.9 0.8 9.9 6.1 0.4 0 0.4 0.4 29 5 22 305 29 0 29 0 -19.6 0 -19.5 -19.7 02/24/2005 20:20:00 8.5 0.5 9.9 6.8 8.3 0.6 9.5 6.8 0.4 0 0.4 0.4 29 4 30 305 28 0 28 0 -19.6 0 -19.5 -19.7 02/24/2005 20:30:00 8.4 0.6 9.5 6.5 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 28 3 25 305 28 0 28 0 -19.6 0 -19.5 -19.5 02/24/2005 20:40:00 7.5 0.8 9.5 5.3 7.4 0.9 9.1 5.3 0.4 0 0.4 0.4 27 4 26 305 28 0 28 0 -19.7 0 -19.5 -19.9 02/24/2005 20:50:00 7.3 0.9 9.1 5.3 7.1 0.9 9.1 5.3 0.4 0 0.4 0.4 25 5 22 305 27 0 27 0 -19.7 0 -19.5 -19.9 02/24/2005 21:00:00 8.2 0.6 9.5 6.5 8 0.6 9.5 6.1 0.4 0 0.4 0.4 27 3 28 305 27 0 27 0 -19.7 0 -19.5 -19.9 02/24/2005 21:10:00 8.7 0.6 10.3 6.8 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 28 4 23 305 27 0 27 0 -19.7 0 -19.5 -19.7 02/24/2005 21:20:00 8.8 0.7 10.3 6.8 8.6 0.8 10.3 6.5 0.4 0 0.4 0.4 26 4 28 305 27 0 27 0 -19.7 0 -19.5 -19.9 02/24/2005 21:30:00 8 0.7 9.9 6.1 7.8 0.8 9.9 6.1 0.4 0 0.4 0.4 27 4 28 305 27 0 27 0 -19.7 0 -19.5 -19.9 02/24/2005 21:40:00 7.9 0.9 10.3 5.7 7.8 0.8 9.9 6.1 0.4 0 0.4 0.4 27 5 28 305 27 0 27 0 -19.6 0 -19.5 -19.7 02/24/2005 21:50:00 8.5 0.8 10.3 6.5 8.4 0.8 10.3 6.5 0.4 0 0.4 0.4 29 4 22 305 27 0 27 0 -19.5 0 -19.3 -19.5 02/24/2005 22:00:00 7.6 0.8 9.5 5.7 7.6 0.8 9.5 5.7 0.4 0 0.4 0.4 21 5 27 305 27 0 27 0 -19.6 0 -19.3 -19.7 02/24/2005 22:10:00 7.6 0.8 9.1 5.7 7.6 0.8 9.5 5.3 0.4 0 0.4 0.4 26 5 30 305 27 0 28 0 -19.7 0 -19.5 -19.7 02/24/2005 22:20:00 7.5 0.8 9.5 5.7 7.3 0.8 9.5 5.3 0.4 0 0.4 0.4 28 6 30 305 28 0 28 0 -19.6 0 -19.3 -19.7 02/24/2005 22:30:00 7.4 1.1 9.5 5.3 7.3 1.1 9.5 5.3 0.4 0 0.4 0.4 30 5 30 305 28 0 28 0 -19.6 0 -19.3 -19.7 02/24/2005 22:40:00 7.6 0.9 9.5 5.7 7.5 1 9.5 5.3 0.4 0 0.4 0.4 29 6 29 305 28 0 28 0 -19.6 0 -19.3 -19.7 02/24/2005 22:50:00 7.9 0.8 9.5 6.5 7.8 0.7 9.5 6.1 0.4 0 0.4 0.4 33 6 29 305 28 0 28 0 -19.5 0.1 -19.2 -19.5 02/24/2005 23:00:00 8.1 0.7 9.9 6.1 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 31 5 29 305 28 0 28 0 -19.4 0 -19.2 -19.5 02/24/2005 23:10:00 7.7 0.9 9.1 5.3 7.5 0.8 9.1 4.9 0.4 0 0.4 0.4 32 5 28 305 28 0 28 0 -19.3 0 -19 -19.5 02/24/2005 23:20:00 7.7 0.8 9.1 5.7 7.6 0.8 9.1 5.7 0.4 0 0.4 0.4 30 5 30 305 28 0 28 0 -19.4 0 -19 -19.5 02/24/2005 23:30:00 7.6 0.7 8.8 5.7 7.5 0.7 8.8 5.7 0.4 0 0.4 0.4 32 5 37 305 29 0 29 0 -19.2 0 -19 -19.5 02/24/2005 23:40:00 7.7 0.7 9.1 5.7 7.6 0.8 9.5 5.3 0.4 0 0.4 0.4 30 5 18 305 29 0 29 0 -19.2 0 -19 -19.3 02/24/2005 23:50:00 7 0.8 8.8 5.3 7 0.9 8.8 4.9 0.4 0 0.4 0.4 31 6 32 305 29 0 29 0 -19.1 0 -18.8 -19.2 02/25/2005 00:00:00 7.2 0.8 9.1 5.3 7.2 0.8 9.1 4.9 0.4 0 0.4 0.4 27 5 27 305 29 0 29 0 -19 0 -18.6 -19 02/25/2005 00:10:00 7.2 0.8 8.8 4.9 7.3 0.8 8.8 4.6 0.4 0 0.4 0.4 32 5 27 305 29 0 29 0 -19 0 -18.8 -19 02/25/2005 00:20:00 6.8 0.8 8.8 4.6 6.8 0.9 8.8 4.6 0.4 0 0.4 0.4 30 6 32 305 29 0 29 0 -19 0.1 -18.6 -19 02/25/2005 00:30:00 7 1 8.8 4.9 6.9 1.1 9.1 4.2 0.4 0 0.4 0.4 34 6 31 305 30 0 29 0 -19 0 -18.8 -19 02/25/2005 00:40:00 7.1 0.6 8.4 5.3 7 0.7 8.8 5.3 0.4 0 0.4 0.4 29 5 37 305 30 0 29 0 -19 0 -18.6 -19 02/25/2005 00:50:00 7.4 0.7 8.8 5.7 7.4 0.7 8.8 5.7 0.4 0 0.4 0.4 24 5 29 305 30 0 30 0 -19.1 0 -19 -19.3 02/25/2005 01:00:00 7.2 0.8 8.8 4.9 7.1 0.8 8.8 4.9 0.4 0 0.4 0.4 26 5 29 305 29 0 29 0 -19.2 0 -19 -19.3 02/25/2005 01:10:00 7.2 0.9 8.8 4.6 7.2 0.8 9.1 4.9 0.4 0 0.4 0.4 27 4 27 305 29 0 29 0 -19.1 0 -19 -19.3 02/25/2005 01:20:00 7.4 0.6 8.8 6.1 7.4 0.7 9.1 5.3 0.4 0 0.4 0.4 28 6 23 305 29 0 29 0 -19.1 0 -18.8 -19.2 02/25/2005 01:30:00 6.8 0.8 8.4 4.9 6.9 0.8 8.8 4.9 0.4 0 0.4 0.4 26 5 22 305 29 0 29 0 -19.1 0 -18.8 -19.2 02/25/2005 01:40:00 7.2 0.9 9.1 4.6 7.1 1 9.5 4.9 0.4 0 0.4 0.4 27 6 26 305 29 0 29 0 -19.1 0 -18.8 -19.2 02/25/2005 01:50:00 7.6 0.7 9.1 5.7 7.6 0.7 9.1 5.7 0.4 0 0.4 0.4 31 5 24 305 29 0 29 0 -19.2 0 -19 -19.3 02/25/2005 02:00:00 7.5 0.8 9.1 5.7 7.5 0.9 9.1 4.9 0.4 0 0.4 0.4 27 5 22 305 29 0 29 0 -19.2 0 -19 -19.3 02/25/2005 02:10:00 7.4 0.7 9.1 5.3 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 35 6 30 305 29 0 28 0 -19.2 0 -19 -19.3 02/25/2005 02:20:00 6.9 0.8 8.8 5.3 6.9 0.7 8.4 5.3 0.4 0 0.4 0.4 30 7 45 305 29 0 29 0 -19.2 0 -19 -19.3 02/25/2005 02:30:00 6.4 0.8 8 4.2 6.4 0.8 8 4.6 0.4 0 0.4 0.4 29 5 30 305 29 0 29 0 -19.2 0 -19 -19.3 02/25/2005 02:40:00 7.2 0.6 8.4 4.9 7.1 0.6 8.4 4.9 0.4 0 0.4 0.4 29 6 33 305 29 0 29 0 -19.1 0 -19 -19.3 02/25/2005 02:50:00 7.5 0.5 8.8 5.7 7.5 0.6 8.8 6.1 0.4 0 0.4 0.4 29 5 35 305 29 0 29 0 -19.2 0 -19 -19.3 02/25/2005 03:00:00 7.1 0.6 8.4 5.3 7.1 0.5 8 5.3 0.4 0 0.4 0.4 32 4 32 305 29 0 29 0 -19.2 0 -19 -19.3 02/25/2005 03:10:00 6.6 0.6 8 5.3 6.7 0.6 8.4 4.9 0.4 0 0.4 0.4 29 5 25 305 29 0 29 0 -19.3 0.1 -19 -19.5 02/25/2005 03:20:00 6.2 0.7 7.6 4.6 6.2 0.7 7.6 4.6 0.4 0 0.4 0.4 27 6 27 305 29 0 29 0 -19.5 0 -19.2 -19.5 02/25/2005 03:30:00 6.9 0.5 8 5.3 6.9 0.5 8 5.3 0.4 0 0.4 0.4 25 5 29 305 28 0 28 0 -19.7 0 -19.3 -19.9 02/25/2005 03:40:00 6.3 0.7 8 4.6 6.3 0.8 8 4.2 0.4 0 0.4 0.4 29 6 27 305 28 0 28 0 -19.7 0 -19.5 -19.9 02/25/2005 03:50:00 6.7 0.5 7.6 5.3 6.7 0.6 8 5.3 0.4 0 0.4 0.4 28 5 29 305 28 0 28 0 -19.7 0 -19.5 -19.9 02/25/2005 04:00:00 6.5 0.8 8 4.2 6.5 0.9 8.4 4.6 0.4 0 0.4 0.4 29 6 35 305 28 0 28 0 -19.7 0 -19.5 -19.9 02/25/2005 04:10:00 6.9 0.6 8 5.3 7 0.6 8.4 5.3 0.4 0 0.4 0.4 24 5 21 305 28 0 28 0 -19.7 0 -19.3 -19.9 02/25/2005 04:20:00 6.5 0.6 7.6 4.9 6.5 0.6 8 4.6 0.4 0 0.4 0.4 23 5 22 305 28 0 27 0 -19.8 0 -19.5 -20.1 02/25/2005 04:30:00 5.8 0.7 7.6 4.2 5.7 0.6 7.6 4.6 0.4 0 0.4 0.4 26 6 29 305 27 0 27 0 -19.8 0 -19.5 -20.1 02/25/2005 04:40:00 6.3 0.6 7.2 4.9 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 28 8 24 305 27 0 27 0 -19.9 0 -19.5 -20.1 02/25/2005 04:50:00 6.8 0.7 8 4.2 6.9 0.7 8.4 4.2 0.4 0 0.4 0.4 23 5 20 305 27 0 27 0 -20 0 -19.7 -20.1 02/25/2005 05:00:00 6.9 0.8 8.8 4.9 6.8 0.7 8.8 5.3 0.4 0 0.4 0.4 33 6 36 305 27 0 27 0 -19.9 0 -19.5 -20.1 02/25/2005 05:10:00 7.2 0.6 8.4 5.3 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 37 5 40 305 27 0 27 0 -19.8 0 -19.5 -19.9 02/25/2005 05:20:00 7.4 0.7 9.1 5.7 7.5 0.7 9.1 5.3 0.4 0 0.4 0.4 25 5 20 305 27 0 27 0 -19.9 0.1 -19.5 -20.1 02/25/2005 05:30:00 7.1 0.9 9.5 5.3 7.1 0.9 9.1 4.9 0.4 0 0.4 0.4 27 6 35 305 27 0 27 0 -20.1 0 -19.9 -20.1 02/25/2005 05:40:00 7.8 0.7 9.5 6.1 7.8 0.6 9.5 5.7 0.4 0 0.4 0.4 31 4 32 305 27 0 27 0 -20.2 0 -19.9 -20.1 02/25/2005 05:50:00 7.9 0.9 9.5 5.3 7.9 1 10.3 5.3 0.4 0 0.4 0.4 26 5 22 305 27 0 27 0 -20.1 0 -19.9 -20.1 02/25/2005 06:00:00 7.5 0.8 8.8 5.3 7.5 0.8 9.1 5.3 0.4 0 0.4 0.4 29 5 26 305 27 0 27 0 -20.1 0 -19.9 -20.1 02/25/2005 06:10:00 7.2 0.8 8.8 5.3 7.2 0.8 8.8 4.9 0.4 0 0.4 0.4 29 6 30 305 27 0 27 0 -20.1 0 -19.9 -20.1 02/25/2005 06:20:00 8.1 0.9 9.9 6.1 8 0.8 10.3 6.1 0.4 0 0.4 0.4 32 5 33 305 27 0 27 0 -20.2 0 -19.9 -20.1 02/25/2005 06:30:00 7.5 0.8 9.5 5.7 7.4 0.8 9.5 5.7 0.4 0 0.4 0.4 29 6 29 305 26 0 26 0 -20 0 -19.9 -20.1 02/25/2005 06:40:00 8.3 0.9 10.3 6.1 8.2 1 10.7 6.1 0.4 0 0.4 0.4 30 4 31 305 26 0 26 0 -20 0 -19.9 -20.1 02/25/2005 06:50:00 8.1 0.7 9.5 5.7 8 0.8 9.9 5.7 0.4 0 0.4 0.4 33 5 33 305 26 0 26 0 -20.2 0 -19.9 -20.2 02/25/2005 07:00:00 8.4 0.8 10.3 6.5 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 29 5 33 305 26 0 26 0 -20.4 0.1 -20.1 -20.6 02/25/2005 07:10:00 7.9 0.9 9.5 5.7 7.8 0.9 9.5 5.7 0.4 0 0.4 0.4 34 5 37 305 25 0 25 0 -20.5 0 -20.2 -20.6 02/25/2005 07:20:00 8.2 0.9 9.9 5.3 8 0.9 9.9 5.7 0.4 0 0.4 0.4 31 5 25 305 25 0 25 0 -20.4 0 -20.2 -20.6 02/25/2005 07:30:00 7.8 1.1 9.9 5.3 7.7 1 9.9 4.9 0.4 0 0.4 0.4 27 5 31 305 25 0 25 0 -20.4 0 -20.1 -20.6 02/25/2005 07:40:00 8.4 0.8 10.3 5.7 8.5 0.9 10.3 5.7 0.4 0 0.4 0.4 23 5 21 305 25 0 25 0 -20.6 0 -20.4 -20.8 02/25/2005 07:50:00 8.4 0.8 10.3 6.1 8.2 0.8 10.3 5.7 0.4 0 0.4 0.4 30 5 32 305 24 0 24 0 -20.7 0 -20.6 -20.8 02/25/2005 08:00:00 7.9 0.9 10.3 6.1 7.7 0.9 10.7 5.7 0.4 0 0.4 0.4 29 6 24 305 24 0 24 0 -20.7 0 -20.8 -20.8 02/25/2005 08:10:00 8.4 0.8 10.3 6.5 8.2 0.8 9.9 6.5 0.4 0 0.4 0.4 27 6 33 305 24 0 24 0 -20.8 0.1 -20.6 -21.1 02/25/2005 08:20:00 8.6 0.7 10.3 6.8 8.5 0.7 9.9 6.5 0.4 0 0.4 0.4 28 5 30 305 23 0 24 0 -21.1 0 -20.8 -21.3 02/25/2005 08:30:00 8.9 0.8 10.7 6.5 8.6 0.9 10.7 5.7 0.4 0 0.4 0.4 31 4 33 305 23 0 23 0 -21.2 0 -21 -21.3 02/25/2005 08:40:00 8.6 0.8 10.7 6.8 8.4 0.8 10.3 6.5 0.4 0 0.4 0.4 34 6 28 305 23 0 22 0 -21.3 0 -21.3 -21.3 02/25/2005 08:50:00 8.8 0.8 10.7 6.8 8.6 0.9 10.7 6.8 0.4 0 0.4 0.4 36 5 27 305 22 0 22 0 -21.3 0 -21.3 -21.5 02/25/2005 09:00:00 8.3 0.6 9.9 6.5 8.1 0.7 9.9 6.5 0.4 0 0.4 0.4 38 5 39 305 22 0 22 0 -21.3 0 -21.1 -21.3 02/25/2005 09:10:00 7.8 0.6 9.5 6.5 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 34 6 21 305 22 0 22 0 -21.1 0.1 -20.8 -21.3 02/25/2005 09:20:00 8.5 0.8 10.7 6.1 8.3 0.9 10.3 6.1 0.4 0 0.4 0.4 29 5 24 305 22 0 22 0 -20.9 0 -20.8 -21.1 02/25/2005 09:30:00 9.4 1.1 11.8 6.5 9.2 1.2 11.5 6.1 0.4 0 0.4 0.4 27 5 27 305 22 0 22 0 -21 0.1 -20.8 -21.3 02/25/2005 09:40:00 9.1 0.8 11.1 7.2 8.9 0.8 11.1 7.2 0.4 0 0.4 0.4 32 5 29 305 22 0 22 0 -21.1 0 -20.8 -21.3 02/25/2005 09:50:00 9.2 1 11.8 6.8 9.1 1 12.6 6.5 0.4 0 0.4 0.4 29 6 18 305 22 0 22 0 -21 0.1 -20.8 -21.3 02/25/2005 10:00:00 8.4 1 11.5 6.5 8.3 1 11.8 6.1 0.4 0 0.4 0.4 28 5 23 305 22 0 22 0 -20.9 0 -20.4 -21.1 02/25/2005 10:10:00 9.1 0.9 11.5 6.8 8.8 0.9 11.5 6.5 0.4 0 0.4 0.4 26 5 20 305 22 0 22 0 -21.1 0.1 -20.8 -21.3 02/25/2005 10:20:00 8.8 0.8 10.7 6.5 8.6 0.7 10.7 6.5 0.4 0 0.4 0.4 27 5 19 305 22 0 22 0 -21.1 0 -21 -21.3 02/25/2005 10:30:00 8.4 0.7 9.9 6.8 8.1 0.7 9.9 6.1 0.4 0 0.4 0.4 32 5 26 305 22 0 22 0 -21.3 0 -21.1 -21.3 02/25/2005 10:40:00 8 0.7 9.9 6.1 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 35 4 38 305 22 0 22 0 -21.3 0 -21.1 -21.3 02/25/2005 10:50:00 7.5 0.8 9.1 5.3 7.4 0.8 8.8 4.9 0.4 0 0.4 0.4 33 5 37 305 22 0 22 0 -21.3 0 -21.1 -21.3 02/25/2005 11:00:00 7.5 0.8 9.9 6.1 7.3 0.8 9.9 5.3 0.4 0 0.4 0.4 27 6 23 305 22 0 22 0 -21.3 0 -21.1 -21.3 02/25/2005 11:10:00 8.2 1 9.9 5.3 8 1 9.9 5.3 0.4 0 0.4 0.4 29 5 24 305 23 0 22 0 -21.2 0 -21.1 -21.3 02/25/2005 11:20:00 7.3 0.7 8.8 5.7 7.1 0.8 9.1 5.3 0.4 0 0.4 0.4 28 5 34 305 24 0 24 0 -21.2 0.1 -21 -21.3 02/25/2005 11:30:00 8.4 1 10.3 5.7 8.2 1 9.9 5.7 0.4 0 0.4 0.4 29 4 26 305 26 1 26 0 -21 0 -20.8 -21.1 02/25/2005 11:40:00 8.2 0.7 9.9 6.5 8 0.7 9.9 6.1 0.4 0 0.4 0.4 31 5 33 305 28 0 27 0 -20.9 0 -20.8 -21.1 02/25/2005 11:50:00 8.3 0.8 9.9 6.5 8.1 0.7 9.9 6.5 0.4 0 0.4 0.4 31 5 30 305 29 0 28 0 -20.7 0 -20.4 -21 02/25/2005 12:00:00 8.3 0.9 10.7 6.5 8.2 0.9 10.7 6.1 0.4 0 0.4 0.4 26 6 15 305 30 0 31 0 -20.5 0.1 -20.1 -20.8 02/25/2005 12:10:00 7.7 0.8 10.3 6.1 7.5 0.9 10.7 6.1 0.4 0 0.4 0.4 32 7 18 305 31 0 30 0 -20.5 0 -20.1 -20.6 02/25/2005 12:20:00 8.2 0.7 10.7 6.5 8.1 0.7 10.7 6.5 0.4 0 0.4 0.4 35 5 27 305 32 0 33 0 -20.3 0.1 -20.1 -20.6 02/25/2005 12:30:00 8.6 1 10.7 6.1 8.4 0.9 10.7 5.7 0.4 0 0.4 0.4 30 5 31 305 34 0 34 0 -20.1 0.1 -19.5 -20.2 02/25/2005 12:40:00 8.6 1 11.1 6.8 8.4 0.9 11.1 6.5 0.4 0 0.4 0.4 31 5 36 305 34 0 35 0 -20 0.1 -19.5 -20.1 02/25/2005 12:50:00 9.2 1.1 11.8 6.8 9 1.2 11.8 6.1 0.4 0 0.4 0.4 31 7 43 305 35 0 35 0 -19.9 0 -19.5 -20.1 02/25/2005 13:00:00 8.6 1 11.1 6.1 8.4 1 11.5 6.5 0.4 0 0.4 0.4 30 6 22 305 36 0 36 0 -19.7 0 -19.3 -19.9 02/25/2005 13:10:00 9.7 0.8 11.5 7.2 9.5 0.9 11.5 7.2 0.4 0 0.4 0.4 33 5 32 305 36 0 36 0 -19.8 0.1 -19.5 -19.9 02/25/2005 13:20:00 8.7 1 11.1 6.1 8.5 1 11.5 5.7 0.4 0 0.4 0.4 28 6 22 305 36 0 36 0 -19.7 0.1 -19.2 -19.9 02/25/2005 13:30:00 10 1.1 12.2 7.2 9.8 1.1 12.6 6.8 0.4 0 0.4 0.4 22 5 22 305 36 0 36 0 -19.6 0 -19.2 -19.7 02/25/2005 13:40:00 9 1 11.1 6.8 8.9 1 11.5 6.5 0.4 0 0.4 0.4 22 6 14 305 36 0 36 0 -19.5 0.1 -19 -19.5 02/25/2005 13:50:00 8.9 0.6 10.3 7.2 8.7 0.6 10.3 7.2 0.4 0 0.4 0.4 28 4 24 305 36 0 36 0 -19.5 0.1 -19 -19.5 02/25/2005 14:00:00 8.1 0.8 10.3 6.1 8 0.8 10.7 6.5 0.4 0 0.4 0.4 26 6 26 305 37 0 38 0 -19.4 0 -19 -19.5 02/25/2005 14:10:00 8.8 1 10.7 6.1 8.7 1 11.1 6.5 0.4 0 0.4 0.4 20 5 24 305 38 0 38 0 -19.3 0 -18.8 -19.5 02/25/2005 14:20:00 8.1 0.7 9.5 6.1 8.1 0.8 9.9 5.7 0.4 0 0.4 0.4 19 5 23 305 38 0 38 0 -19.2 0 -19 -19.3 02/25/2005 14:30:00 7.2 0.9 9.5 5.3 7.1 1 9.5 4.9 0.4 0 0.4 0.4 22 6 27 305 39 0 38 0 -19.1 0 -19 -19.3 02/25/2005 14:40:00 7.5 0.6 8.8 5.7 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 22 6 19 305 40 0 40 0 -19.1 0 -19 -19.2 02/25/2005 14:50:00 7.8 0.6 9.1 6.5 7.8 0.7 9.5 6.1 0.4 0 0.4 0.4 21 5 18 305 41 0 41 0 -19.1 0 -19 -19.3 02/25/2005 15:00:00 6.9 0.8 8.8 4.9 7 0.8 9.1 4.9 0.4 0 0.4 0.4 25 6 27 305 42 0 43 0 -19.1 0 -18.8 -19.2 02/25/2005 15:10:00 7.3 0.6 8.8 5.7 7.1 0.7 8.8 4.9 0.4 0 0.4 0.4 25 6 21 305 44 0 44 0 -19.1 0 -19 -19.2 02/25/2005 15:20:00 7.3 0.7 8.4 5.3 7.2 0.6 8.4 5.3 0.4 0 0.4 0.4 22 6 16 305 45 0 45 0 -19 0 -18.8 -19 02/25/2005 15:30:00 6.5 0.8 8.8 4.6 6.4 0.9 8.8 4.6 0.4 0 0.4 0.4 18 7 9 305 47 0 47 0 -18.8 0 -18.4 -19 02/25/2005 15:40:00 7 0.8 8.8 4.6 7 0.9 9.5 4.9 0.4 0 0.4 0.4 17 7 15 305 48 0 49 0 -18.9 0 -18.6 -19 02/25/2005 15:50:00 7.9 0.7 9.9 5.7 7.9 0.8 9.9 5.3 0.4 0 0.4 0.4 17 4 14 305 49 0 50 0 -19 0 -18.8 -19.2 02/25/2005 16:00:00 8.4 0.5 9.5 6.5 8.3 0.6 9.5 6.1 0.4 0 0.4 0.4 19 4 21 305 50 0 50 0 -19.1 0 -19 -19.2 02/25/2005 16:10:00 6.8 0.8 8.4 4.6 6.7 0.8 8.8 4.2 0.4 0 0.4 0.4 23 7 19 305 49 0 49 0 -19 0.1 -18.8 -19.2 02/25/2005 16:20:00 7.6 1.1 9.9 4.9 7.5 1.2 9.9 4.9 0.4 0 0.4 0.4 20 6 16 305 51 0 51 0 -18.9 0 -18.6 -19 02/25/2005 16:30:00 7.7 0.8 9.5 6.1 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 20 5 14 305 52 0 52 0 -19 0.1 -18.4 -19 02/25/2005 16:40:00 7.2 0.9 8.8 4.6 7.2 0.9 8.8 4.9 0.4 0 0.4 0.4 14 6 15 305 52 0 52 0 -18.9 0.1 -18.4 -19 02/25/2005 16:50:00 7.4 0.7 8.8 5.3 7.4 0.8 8.8 5.3 0.4 0 0.4 0.4 12 4 10 305 52 0 52 0 -19 0.1 -18.4 -19 02/25/2005 17:00:00 7.7 0.8 9.1 4.9 7.7 0.8 9.1 4.9 0.4 0 0.4 0.4 17 5 17 305 52 0 52 0 -19 0.1 -18.4 -19 02/25/2005 17:10:00 7.2 0.8 8.4 4.6 7.1 0.8 8.8 4.9 0.4 0 0.4 0.4 20 6 16 305 52 0 52 0 -19.1 0 -18.6 -19.2 02/25/2005 17:20:00 8.5 0.5 9.9 6.8 8.5 0.5 9.9 6.8 0.4 0 0.4 0.4 18 4 16 305 52 0 52 0 -19.2 0.1 -18.8 -19.5 02/25/2005 17:30:00 7.7 1 9.9 5.3 7.6 1 9.9 5.3 0.4 0 0.4 0.4 22 6 24 305 51 0 51 0 -19.2 0.1 -18.8 -19.5 02/25/2005 17:40:00 7.7 1 9.9 5.7 7.6 1 9.5 5.3 0.4 0 0.4 0.4 25 6 29 305 50 0 50 0 -19.3 0 -19 -19.5 02/25/2005 17:50:00 8.3 0.7 10.3 6.1 8.2 0.8 9.9 6.1 0.4 0 0.4 0.4 26 5 17 305 49 0 49 0 -19.4 0.1 -19 -19.5 02/25/2005 18:00:00 8.6 0.7 10.3 6.8 8.4 0.7 9.9 6.8 0.4 0 0.4 0.4 26 4 28 305 48 0 48 0 -19.4 0.1 -19 -19.5 02/25/2005 18:10:00 7.7 0.9 9.5 4.9 7.6 0.9 9.5 5.3 0.4 0 0.4 0.4 25 4 27 305 47 0 47 0 -19.4 0.1 -19 -19.5 02/25/2005 18:20:00 7.5 0.8 9.1 5.3 7.3 0.8 9.1 5.7 0.4 0 0.4 0.4 22 6 22 305 46 0 46 0 -19.4 0.1 -19 -19.5 02/25/2005 18:30:00 7.5 0.7 9.1 6.1 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 22 5 23 305 45 0 46 0 -19.6 0 -19 -19.7 02/25/2005 18:40:00 8 0.7 9.9 6.1 7.8 0.8 9.9 6.1 0.4 0 0.4 0.4 22 6 24 305 44 1 44 0 -19.7 0 -19.3 -19.9 02/25/2005 18:50:00 8.1 0.4 9.1 6.8 8 0.5 9.5 6.5 0.4 0 0.4 0.4 26 3 27 305 41 1 40 0 -19.8 0 -19.5 -20.1 02/25/2005 19:00:00 8.2 0.9 10.3 5.7 8.1 0.9 9.9 5.3 0.4 0 0.4 0.4 23 5 22 305 39 1 38 0 -19.9 0 -19.5 -20.1 02/25/2005 19:10:00 8.2 0.7 9.5 6.1 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 20 4 21 305 36 1 34 0 -20 0.1 -19.7 -20.1 02/25/2005 19:20:00 8 0.7 9.9 6.1 7.8 0.8 9.5 6.1 0.4 0 0.4 0.4 19 5 15 305 32 1 34 0 -20.2 0 -20.1 -20.2 02/25/2005 19:30:00 8 0.6 9.5 5.7 7.7 0.7 9.1 5.3 0.4 0 0.4 0.4 24 4 27 305 30 1 30 0 -20.2 0 -20.1 -20.4 02/25/2005 19:40:00 6.4 0.6 8 4.9 6.2 0.6 8.4 4.9 0.4 0 0.4 0.4 24 4 24 305 28 0 28 0 -20.3 0 -20.1 -20.6 02/25/2005 19:50:00 6.6 0.7 8.8 4.9 6.2 0.7 8 4.6 0.4 0 0.4 0.4 26 6 30 305 27 0 26 0 -20.4 0.1 -20.1 -20.6 02/25/2005 20:00:00 8 0.6 9.1 6.5 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 27 4 33 305 26 0 26 0 -20.5 0 -20.1 -20.8 02/25/2005 20:10:00 8.6 0.5 9.9 6.8 8.3 0.6 9.9 6.8 0.4 0 0.4 0.4 25 4 26 305 25 0 25 0 -20.5 0 -20.2 -20.6 02/25/2005 20:20:00 7.5 0.9 9.9 5.3 7.4 0.9 9.5 5.3 0.4 0 0.4 0.4 21 5 23 305 25 0 25 0 -20.5 0 -20.2 -20.8 02/25/2005 20:30:00 7.5 0.8 9.5 4.9 7.2 0.9 8.8 4.6 0.4 0 0.4 0.4 25 5 25 305 24 0 24 0 -20.6 0 -20.4 -20.8 02/25/2005 20:40:00 7.7 0.8 9.9 5.7 7.4 0.8 9.1 5.7 0.4 0 0.4 0.4 25 5 30 305 24 0 24 0 -20.6 0 -20.4 -20.8 02/25/2005 20:50:00 7.5 1 9.5 5.3 7.3 1 9.5 5.3 0.4 0 0.4 0.4 19 5 20 305 24 0 24 0 -20.6 0 -20.4 -20.8 02/25/2005 21:00:00 8.2 0.7 10.3 6.5 8.1 0.7 9.9 6.5 0.4 0 0.4 0.4 19 4 22 305 23 0 24 0 -20.6 0 -20.4 -20.8 02/25/2005 21:10:00 7.3 1 9.5 5.3 7.2 1 9.5 5.3 0.4 0 0.4 0.4 24 5 22 305 23 0 24 0 -20.7 0 -20.4 -20.8 02/25/2005 21:20:00 6.7 0.7 8 4.9 6.5 0.7 8.4 4.6 0.4 0 0.4 0.4 26 5 31 305 23 0 23 0 -20.7 0 -20.6 -21 02/25/2005 21:30:00 6.9 0.7 8.4 4.9 6.6 0.7 8.4 4.6 0.4 0 0.4 0.4 23 5 23 305 23 0 23 0 -20.7 0 -20.6 -21 02/25/2005 21:40:00 7.6 0.8 9.5 4.9 7.5 0.7 9.5 5.3 0.4 0 0.4 0.4 23 6 25 305 23 0 23 0 -20.6 0 -20.4 -20.8 02/25/2005 21:50:00 7.9 0.8 9.9 5.7 7.8 0.9 10.3 5.7 0.4 0 0.4 0.4 23 5 29 305 23 0 22 0 -20.6 0.1 -20.1 -20.8 02/25/2005 22:00:00 6.9 1 9.1 4.9 6.7 1 9.1 4.6 0.4 0 0.4 0.4 25 5 33 305 23 0 23 0 -20.6 0.1 -20.2 -20.8 02/25/2005 22:10:00 7.9 0.7 10.3 6.5 7.7 0.8 9.9 6.1 0.4 0 0.4 0.4 23 5 23 305 23 0 23 0 -20.4 0 -20.2 -20.6 02/25/2005 22:20:00 7.2 0.8 8.8 5.3 7 0.7 8.8 5.3 0.4 0 0.4 0.4 23 6 20 305 23 0 23 0 -20.4 0 -20.1 -20.6 02/25/2005 22:30:00 7.6 0.8 9.5 5.7 7.4 0.9 9.9 5.3 0.4 0 0.4 0.4 23 5 26 305 23 0 23 0 -20.3 0 -20.1 -20.6 02/25/2005 22:40:00 7.4 0.8 9.1 5.3 7.1 0.9 9.1 5.3 0.4 0 0.4 0.4 23 5 24 305 23 0 23 0 -20.2 0 -19.9 -20.4 02/25/2005 22:50:00 7.6 1 9.9 5.3 7.4 1 9.9 5.3 0.4 0 0.4 0.4 23 5 20 305 23 0 24 0 -20 0.1 -19.5 -20.1 02/25/2005 23:00:00 7.6 0.8 9.9 6.1 7.4 0.8 10.3 5.3 0.4 0 0.4 0.4 22 5 24 305 24 0 24 0 -19.9 0 -19.5 -20.1 02/25/2005 23:10:00 8.4 0.8 10.7 6.5 8.1 0.9 10.3 6.1 0.4 0 0.4 0.4 20 4 10 305 24 0 24 0 -19.8 0 -19.5 -20.1 02/25/2005 23:20:00 8.3 0.8 10.7 5.7 8.1 0.9 9.9 5.7 0.4 0 0.4 0.4 18 5 19 305 24 0 24 0 -19.6 0 -19.5 -19.7 02/25/2005 23:30:00 8.9 0.7 10.7 6.8 8.7 0.8 10.3 6.8 0.4 0 0.4 0.4 23 5 27 305 25 0 25 0 -19.6 0 -19.5 -19.7 02/25/2005 23:40:00 8.2 1 10.7 5.7 8 1 9.9 5.3 0.4 0 0.4 0.4 23 6 23 305 25 0 25 0 -19.5 0 -19.3 -19.5 02/25/2005 23:50:00 8.1 1 10.7 5.7 8 1.2 10.7 4.9 0.4 0 0.4 0.4 20 6 31 305 25 0 25 0 -19.6 0 -19.5 -19.5 02/26/2005 00:00:00 8.5 0.8 10.3 6.5 8.4 0.9 10.3 6.1 0.4 0 0.4 0.4 21 5 25 305 26 0 26 0 -19.5 0 -19.3 -19.5 02/26/2005 00:10:00 8.6 1 10.7 6.1 8.5 1 11.1 6.5 0.4 0 0.4 0.4 18 4 17 305 26 0 26 0 -19.5 0 -19.2 -19.5 02/26/2005 00:20:00 9 0.7 10.3 6.8 8.9 0.7 10.3 6.8 0.4 0 0.4 0.4 19 4 17 305 26 0 26 0 -19.5 0 -19.2 -19.5 02/26/2005 00:30:00 8 0.8 9.9 6.5 7.9 0.8 9.9 6.1 0.4 0 0.4 0.4 19 5 15 305 26 0 26 0 -19.6 0 -19.5 -19.7 02/26/2005 00:40:00 7.8 0.8 9.5 5.7 7.5 0.8 9.1 5.3 0.4 0 0.4 0.4 18 5 21 305 26 0 26 0 -19.7 0 -19.3 -19.7 02/26/2005 00:50:00 8.2 0.9 10.3 6.1 8.2 1 10.3 5.7 0.4 0 0.4 0.4 18 5 25 305 25 0 25 0 -19.7 0 -19.5 -19.9 02/26/2005 01:00:00 9.1 0.9 10.7 6.8 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 18 5 21 305 25 0 25 0 -19.7 0 -19.5 -19.9 02/26/2005 01:10:00 9.3 0.9 11.1 6.5 9.1 0.9 11.1 6.5 0.4 0 0.4 0.4 17 4 16 305 25 0 25 0 -19.8 0 -19.5 -20.1 02/26/2005 01:20:00 8.1 1.2 10.3 5.7 7.9 1.1 10.7 5.3 0.4 0 0.4 0.4 16 5 15 305 25 0 25 0 -19.9 0 -19.5 -20.1 02/26/2005 01:30:00 8.6 0.7 10.3 6.8 8.5 0.7 9.9 6.8 0.4 0 0.4 0.4 15 5 18 305 25 0 25 0 -19.8 0 -19.5 -20.1 02/26/2005 01:40:00 7.8 1 9.9 5.7 7.6 1 9.9 5.7 0.4 0 0.4 0.4 17 5 17 305 25 0 25 0 -19.9 0 -19.5 -20.1 02/26/2005 01:50:00 8.3 0.7 9.9 6.1 8.2 0.8 9.9 5.7 0.4 0 0.4 0.4 15 4 14 305 25 0 25 0 -19.9 0 -19.5 -20.1 02/26/2005 02:00:00 8.1 0.8 9.5 5.7 8 0.8 9.9 5.7 0.4 0 0.4 0.4 12 4 14 305 25 0 25 0 -19.9 0 -19.5 -20.1 02/26/2005 02:10:00 7.9 0.9 9.9 5.7 7.8 0.9 9.9 5.3 0.4 0 0.4 0.4 13 5 9 305 25 0 25 0 -19.9 0 -19.5 -20.1 02/26/2005 02:20:00 8 0.7 9.5 6.5 7.9 0.7 9.5 6.5 0.4 0 0.4 0.4 19 4 18 305 25 0 25 0 -19.9 0 -19.5 -20.1 02/26/2005 02:30:00 7.4 0.6 8.8 5.7 7.2 0.7 8.8 5.7 0.4 0 0.4 0.4 24 5 31 305 25 0 25 0 -19.8 0 -19.5 -19.9 02/26/2005 02:40:00 6.5 0.7 8 4.6 6.4 0.7 8 4.9 0.4 0 0.4 0.4 17 6 11 305 25 0 25 0 -19.8 0 -19.5 -20.1 02/26/2005 02:50:00 6.7 0.8 8.4 4.6 6.6 0.8 8.4 4.6 0.4 0 0.4 0.4 15 4 21 305 25 0 25 0 -19.9 0 -19.5 -20.1 02/26/2005 03:00:00 7.2 0.8 8.8 5.3 7.1 0.8 8.8 5.3 0.4 0 0.4 0.4 14 4 13 305 24 0 25 0 -20 0.1 -19.7 -20.1 02/26/2005 03:10:00 7.8 0.6 9.1 6.5 7.7 0.6 9.1 5.7 0.4 0 0.4 0.4 19 4 21 305 24 0 24 0 -19.9 0 -19.7 -20.1 02/26/2005 03:20:00 7.3 0.7 8.8 5.7 7.2 0.8 8.8 5.3 0.4 0 0.4 0.4 17 5 20 305 24 0 24 0 -19.9 0 -19.5 -20.1 02/26/2005 03:30:00 7.1 0.8 8.8 4.9 7 0.7 9.1 5.3 0.4 0 0.4 0.4 22 6 21 305 25 0 25 0 -19.9 0.1 -19.5 -20.1 02/26/2005 03:40:00 7.3 0.7 8.8 5.3 7.2 0.7 8.8 5.7 0.4 0 0.4 0.4 16 5 12 305 25 0 25 0 -19.7 0 -19.5 -19.9 02/26/2005 03:50:00 7.8 0.9 9.5 5.3 7.6 0.9 9.5 5.3 0.4 0 0.4 0.4 16 4 15 305 25 0 25 0 -19.7 0 -19.5 -19.9 02/26/2005 04:00:00 8.4 0.8 9.9 6.8 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 14 5 23 305 25 0 25 0 -19.7 0 -19.5 -19.9 02/26/2005 04:10:00 8.2 1 10.3 5.7 8.1 1 10.3 5.7 0.4 0 0.4 0.4 17 4 14 305 25 0 25 0 -19.8 0.1 -19.5 -20.1 02/26/2005 04:20:00 7.5 0.7 9.1 6.1 7.4 0.8 9.5 5.7 0.4 0 0.4 0.4 17 5 27 305 25 0 25 0 -19.7 0 -19.5 -19.9 02/26/2005 04:30:00 7.7 0.6 8.8 6.1 7.6 0.7 9.1 5.3 0.4 0 0.4 0.4 14 5 18 305 25 0 25 0 -19.7 0 -19.5 -19.9 02/26/2005 04:40:00 7 0.8 8.8 4.9 6.9 0.8 8.4 4.9 0.4 0 0.4 0.4 18 5 18 305 25 0 25 0 -19.9 0 -19.5 -20.1 02/26/2005 04:50:00 7.3 0.8 8.8 5.7 7.1 0.7 8.4 5.7 0.4 0 0.4 0.4 20 5 17 305 25 0 25 0 -20 0.1 -19.7 -20.1 02/26/2005 05:00:00 7.5 0.8 9.1 5.3 7.4 0.8 9.1 5.3 0.4 0 0.4 0.4 18 6 14 305 24 0 25 0 -20.1 0 -19.9 -20.1 02/26/2005 05:10:00 8 0.9 10.3 6.1 7.8 0.9 9.9 5.3 0.4 0 0.4 0.4 21 5 19 305 24 0 24 0 -20.2 0 -20.1 -20.4 02/26/2005 05:20:00 7.9 0.7 9.5 6.5 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 23 5 22 305 24 0 24 0 -20.4 0 -20.1 -20.6 02/26/2005 05:30:00 6.9 0.8 8.4 4.6 6.8 0.7 8.4 4.9 0.4 0 0.4 0.4 22 5 35 305 24 0 24 0 -20.4 0 -20.2 -20.6 02/26/2005 05:40:00 8.1 0.7 9.9 6.1 7.9 0.8 9.9 6.1 0.4 0 0.4 0.4 13 6 12 305 23 0 23 0 -20.2 0 -20.1 -20.4 02/26/2005 05:50:00 7.6 0.6 9.1 6.1 7.6 0.6 8.8 6.1 0.4 0 0.4 0.4 19 5 23 305 23 0 23 0 -20.2 0 -20.1 -20.4 02/26/2005 06:00:00 7.6 0.8 9.1 5.7 7.4 0.9 9.5 5.3 0.4 0 0.4 0.4 22 5 19 305 23 0 23 0 -20.3 0 -20.1 -20.6 02/26/2005 06:10:00 7.3 0.6 8.8 5.7 7.1 0.7 8.8 5.3 0.4 0 0.4 0.4 24 5 26 305 23 0 23 0 -20.4 0 -20.1 -20.6 02/26/2005 06:20:00 7.5 0.6 8.8 5.7 7.3 0.7 8.8 5.7 0.4 0 0.4 0.4 23 5 16 305 23 0 23 0 -20.3 0 -20.1 -20.6 02/26/2005 06:30:00 8.1 0.9 10.3 6.1 7.9 0.8 10.3 6.1 0.4 0 0.4 0.4 20 5 16 305 23 0 23 0 -20.5 0 -20.2 -20.8 02/26/2005 06:40:00 8.9 0.8 11.1 6.8 8.8 1 11.1 6.5 0.4 0 0.4 0.4 21 5 21 305 23 0 23 0 -20.6 0.1 -20.2 -20.8 02/26/2005 06:50:00 7.8 0.9 10.3 6.1 7.6 0.9 10.3 5.7 0.4 0 0.4 0.4 21 6 19 305 23 0 22 0 -20.6 0 -20.4 -20.8 02/26/2005 07:00:00 9.1 1 11.5 6.5 8.9 1.1 11.8 6.1 0.4 0 0.4 0.4 20 5 19 305 22 0 22 0 -20.6 0 -20.4 -20.8 02/26/2005 07:10:00 8.6 1 10.7 6.5 8.4 1 10.7 6.1 0.4 0 0.4 0.4 24 5 18 305 22 0 22 0 -20.6 0 -20.4 -20.8 02/26/2005 07:20:00 9.5 1.2 12.2 6.8 9.3 1.2 12.2 6.5 0.4 0 0.4 0.4 19 6 14 305 22 0 22 0 -20.6 0 -20.4 -20.8 02/26/2005 07:30:00 9.3 1.1 11.8 6.8 9.1 1 11.5 6.5 0.4 0 0.4 0.4 19 6 26 305 22 0 22 0 -20.6 0 -20.4 -20.8 02/26/2005 07:40:00 8.7 1.1 11.8 6.1 8.5 1.1 11.8 6.1 0.4 0 0.4 0.4 19 6 15 305 22 0 22 0 -20.6 0 -20.4 -20.8 02/26/2005 07:50:00 9.3 1 12.2 6.8 9.2 1 11.8 7.2 0.4 0 0.4 0.4 21 5 29 305 22 0 22 0 -20.7 0 -20.6 -20.8 02/26/2005 08:00:00 9.9 0.9 12.2 7.6 9.7 0.9 11.8 7.2 0.4 0 0.4 0.4 21 5 24 305 22 0 22 0 -20.7 0 -20.6 -20.8 02/26/2005 08:10:00 8.9 1 11.5 6.5 8.6 1.1 11.5 6.1 0.4 0 0.4 0.4 22 6 18 305 22 0 22 0 -20.8 0 -20.8 -21 02/26/2005 08:20:00 8.8 1.1 11.5 6.5 8.7 1.2 11.5 5.7 0.4 0 0.4 0.4 23 6 13 305 22 0 22 0 -20.8 0 -20.8 -21 02/26/2005 08:30:00 9 1.1 11.8 6.1 8.8 1.1 11.5 6.1 0.4 0 0.4 0.4 21 6 22 305 22 0 22 0 -20.7 0 -20.6 -21 02/26/2005 08:40:00 9.3 1 11.8 6.5 9 1.1 12.2 6.5 0.4 0 0.4 0.4 24 5 33 305 22 0 22 0 -20.8 0 -20.8 -21 02/26/2005 08:50:00 9.6 1 12.2 6.8 9.4 1 12.2 7.2 0.4 0 0.4 0.4 21 6 19 305 22 0 22 0 -20.9 0 -20.8 -21.1 02/26/2005 09:00:00 9.5 1 11.8 6.8 9.3 1 12.2 6.8 0.4 0 0.4 0.4 21 5 21 305 22 0 22 0 -21 0 -20.8 -21.1 02/26/2005 09:10:00 8.8 0.8 10.7 6.1 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 20 5 23 305 22 0 22 0 -21 0 -20.8 -21.1 02/26/2005 09:20:00 9.4 0.9 11.8 6.8 9.3 0.9 11.8 6.8 0.4 0 0.4 0.4 19 6 14 305 21 0 21 0 -21 0 -20.8 -21.3 02/26/2005 09:30:00 9.4 0.8 11.5 7.2 9.3 0.8 11.1 6.8 0.4 0 0.4 0.4 20 6 18 305 21 0 21 0 -21 0 -21 -21.3 02/26/2005 09:40:00 8.9 0.8 10.7 6.8 8.7 0.7 11.1 7.2 0.4 0 0.4 0.4 21 5 15 305 21 0 21 0 -21.1 0.1 -21 -21.3 02/26/2005 09:50:00 9.2 0.9 11.5 7.2 9.1 0.9 11.8 7.2 0.4 0 0.4 0.4 19 5 27 305 21 0 21 0 -21 0 -20.8 -21.3 02/26/2005 10:00:00 8.1 0.8 10.3 6.1 7.9 0.9 9.9 5.3 0.4 0 0.4 0.4 22 6 33 305 21 0 21 0 -21.1 0.1 -21 -21.3 02/26/2005 10:10:00 9 1 11.1 6.8 9 1 11.5 6.8 0.4 0 0.4 0.4 18 6 22 305 21 0 21 0 -21 0 -20.8 -21.3 02/26/2005 10:20:00 8.8 1 11.5 6.5 8.7 1 11.5 6.1 0.4 0 0.4 0.4 15 5 13 305 21 0 21 0 -20.9 0 -20.8 -21.1 02/26/2005 10:30:00 7.7 0.8 11.1 6.1 7.7 0.8 10.3 6.1 0.4 0 0.4 0.4 16 5 7 305 22 0 21 0 -21 0 -20.8 -21.1 02/26/2005 10:40:00 9.1 0.8 10.7 6.5 9 0.8 10.7 6.8 0.4 0 0.4 0.4 19 5 17 305 22 0 22 0 -21 0 -20.8 -21.1 02/26/2005 10:50:00 8.3 0.8 10.7 6.5 8.2 0.9 10.7 6.1 0.4 0 0.4 0.4 19 5 21 305 22 0 22 0 -21 0 -20.8 -21.3 02/26/2005 11:00:00 7.8 1 10.3 5.7 7.7 1 10.3 5.7 0.4 0 0.4 0.4 18 5 18 305 22 0 22 0 -20.9 0 -20.8 -21.1 02/26/2005 11:10:00 8 0.9 10.3 5.7 7.9 1 10.7 5.7 0.4 0 0.4 0.4 20 5 18 305 23 0 22 0 -20.8 0 -20.6 -21 02/26/2005 11:20:00 8.3 0.8 9.9 5.7 8.2 0.7 9.9 5.7 0.4 0 0.4 0.4 21 5 22 305 24 0 24 0 -20.7 0 -20.4 -21 02/26/2005 11:30:00 7.9 0.9 9.9 6.1 7.8 1 9.9 5.3 0.4 0 0.4 0.4 16 5 16 305 25 0 25 0 -20.6 0.1 -20.1 -20.8 02/26/2005 11:40:00 8.5 0.8 10.7 6.1 8.5 0.8 10.7 6.5 0.4 0 0.4 0.4 22 4 21 305 26 0 27 0 -20.6 0.1 -20.2 -20.8 02/26/2005 11:50:00 9 0.7 10.7 6.8 8.9 0.7 10.7 6.8 0.4 0 0.4 0.4 21 4 24 305 27 0 27 0 -20.4 0 -20.1 -20.8 02/26/2005 12:00:00 8.6 1 10.3 6.1 8.4 1 10.7 6.1 0.4 0 0.4 0.4 20 6 19 305 28 0 28 0 -20.2 0 -19.7 -20.4 02/26/2005 12:10:00 8.9 0.8 10.7 6.8 8.9 0.7 10.3 6.5 0.4 0 0.4 0.4 19 4 18 305 28 0 28 0 -20.1 0.1 -19.7 -20.1 02/26/2005 12:20:00 9.1 0.6 10.7 7.2 8.9 0.7 10.7 6.5 0.4 0 0.4 0.4 18 4 15 305 29 0 29 0 -20 0.1 -19.5 -20.1 02/26/2005 12:30:00 8.4 1 10.3 5.3 8.3 1 10.3 5.3 0.4 0 0.4 0.4 19 6 15 305 30 0 29 0 -19.8 0 -19.5 -20.1 02/26/2005 12:40:00 8.5 0.9 10.3 6.5 8.3 1 10.3 5.3 0.4 0 0.4 0.4 24 4 25 305 31 0 31 0 -19.8 0.1 -19.3 -20.1 02/26/2005 12:50:00 8 0.9 9.9 5.7 7.9 0.8 9.9 6.1 0.4 0 0.4 0.4 26 4 29 305 32 0 32 0 -19.7 0 -19.3 -19.9 02/26/2005 13:00:00 8 0.8 9.9 5.7 7.9 0.7 9.9 5.7 0.4 0 0.4 0.4 25 5 19 305 33 0 33 0 -19.5 0.1 -19 -19.7 02/26/2005 13:10:00 8 0.7 9.5 6.5 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 24 4 27 305 34 0 34 0 -19.3 0.1 -19 -19.5 02/26/2005 13:20:00 8.4 0.8 9.9 6.5 8.3 0.9 10.7 6.1 0.4 0 0.4 0.4 22 6 24 305 35 0 35 0 -19.1 0 -19 -19.2 02/26/2005 13:30:00 7.9 0.9 10.3 5.7 7.9 0.9 9.9 6.1 0.4 0 0.4 0.4 20 6 27 305 35 0 34 0 -19 0 -18.8 -19.2 02/26/2005 13:40:00 8.7 0.7 10.3 6.5 8.5 0.7 9.9 6.5 0.4 0 0.4 0.4 18 5 17 305 35 0 35 0 -18.7 0.1 -18.4 -19 02/26/2005 13:50:00 8.8 0.9 11.1 6.5 8.7 0.9 11.1 6.1 0.4 0 0.4 0.4 20 7 13 305 35 0 35 0 -18.7 0 -18.4 -19 02/26/2005 14:00:00 9.5 1.1 11.5 6.5 9.4 1.1 11.5 6.5 0.4 0 0.4 0.4 17 4 14 305 35 0 35 0 -18.7 0 -18.4 -19 02/26/2005 14:10:00 9.6 1.2 12.2 6.8 9.6 1.1 12.2 6.8 0.4 0 0.4 0.4 17 5 25 305 35 0 35 0 -18.7 0.1 -18.4 -19 02/26/2005 14:20:00 10.5 0.9 12.2 8 10.4 1 12.6 8 0.4 0 0.4 0.4 17 4 18 305 35 0 35 0 -18.6 0 -18.4 -18.8 02/26/2005 14:30:00 9.4 0.9 12.2 6.8 9.4 0.9 11.5 6.5 0.4 0 0.4 0.4 18 6 11 305 35 0 35 0 -18.6 0 -18.4 -18.8 02/26/2005 14:40:00 9.2 1 11.1 6.5 9.2 1 11.1 6.5 0.4 0 0.4 0.4 16 5 17 305 35 0 35 0 -18.6 0 -18.4 -18.8 02/26/2005 14:50:00 9.5 1 11.8 6.5 9.4 1 11.5 6.8 0.4 0 0.4 0.4 14 5 22 305 34 0 34 0 -18.5 0 -18.2 -18.4 02/26/2005 15:00:00 9.1 0.9 11.5 7.2 9 0.9 11.1 6.8 0.4 0 0.4 0.4 13 5 12 305 34 0 34 0 -18.3 0 -18.1 -18.4 02/26/2005 15:10:00 9.2 1 11.5 6.1 9.1 1 11.1 5.7 0.4 0 0.4 0.4 12 5 11 305 35 0 34 0 -18.3 0 -18.1 -18.4 02/26/2005 15:20:00 8.6 0.9 10.7 6.5 8.7 0.9 10.7 6.5 0.4 0 0.4 0.4 9 6 18 305 35 0 35 0 -18.3 0 -17.9 -18.4 02/26/2005 15:30:00 8.7 1.1 10.7 6.1 8.7 1.1 10.7 6.1 0.4 0 0.4 0.4 6 6 2 305 35 0 35 0 -18.3 0.1 -17.9 -18.4 02/26/2005 15:40:00 8.8 1 11.1 6.5 8.7 1 11.1 6.5 0.4 0 0.4 0.4 13 9 356 305 35 0 35 0 -18.3 0.1 -17.9 -18.4 02/26/2005 15:50:00 10 1 12.2 7.2 9.9 1.1 12.6 7.2 0.4 0 0.4 0.4 21 4 25 305 35 0 35 0 -18.6 0.1 -18.1 -18.8 02/26/2005 16:00:00 9.8 0.9 11.8 7.2 9.8 0.9 11.8 6.8 0.4 0 0.4 0.4 18 5 23 305 35 0 34 0 -18.5 0 -18.1 -18.8 02/26/2005 16:10:00 9 0.9 11.5 6.8 9 1 11.1 6.1 0.4 0 0.4 0.4 17 5 14 305 35 0 35 0 -18.4 0.1 -18.1 -18.6 02/26/2005 16:20:00 9.1 1 11.1 6.5 9.1 1 11.1 6.1 0.4 0 0.4 0.4 15 4 15 305 36 0 35 0 -18.3 0.1 -17.9 -18.4 02/26/2005 16:30:00 9 1.1 11.5 6.1 8.9 1.2 11.1 5.7 0.4 0 0.4 0.4 20 6 26 305 37 0 37 0 -18.3 0.2 -17.9 -18.4 02/26/2005 16:40:00 8.4 0.8 9.9 6.5 8.2 0.9 10.3 6.5 0.4 0 0.4 0.4 22 7 22 305 38 0 38 0 -18.2 0.1 -17.9 -18.4 02/26/2005 16:50:00 8.8 0.9 10.7 6.1 8.7 1 11.5 6.1 0.4 0 0.4 0.4 22 6 25 305 39 0 39 0 -18.2 0.1 -17.9 -18.4 02/26/2005 17:00:00 8.4 0.8 10.3 6.1 8.2 1 10.3 6.1 0.4 0 0.4 0.4 18 6 16 305 38 0 38 0 -18.1 0 -17.7 -18.4 02/26/2005 17:10:00 9.4 1 11.1 6.5 9.3 1 11.5 6.8 0.4 0 0.4 0.4 17 6 10 305 37 0 37 0 -18.1 0.1 -17.7 -18.2 02/26/2005 17:20:00 8.5 0.9 10.7 6.1 8.3 0.9 10.3 5.7 0.4 0 0.4 0.4 19 6 21 305 35 0 36 0 -18 0.1 -17.5 -18.2 02/26/2005 17:30:00 9 0.7 10.3 6.8 9 0.7 10.7 7.2 0.4 0 0.4 0.4 14 4 17 305 35 0 35 0 -18 0 -17.5 -18.1 02/26/2005 17:40:00 8.7 1.1 10.7 6.1 8.7 1.1 11.1 6.1 0.4 0 0.4 0.4 16 6 22 305 34 0 34 0 -17.9 0.1 -17.5 -18.1 02/26/2005 17:50:00 9.1 1 11.5 6.8 9 1 11.5 6.8 0.4 0 0.4 0.4 17 6 19 305 34 0 34 0 -17.9 0 -17.7 -18.1 02/26/2005 18:00:00 9 0.8 11.1 6.5 8.9 0.8 11.1 6.8 0.4 0 0.4 0.4 20 5 22 305 34 0 34 0 -18 0 -17.5 -18.1 02/26/2005 18:10:00 9.2 0.9 10.7 6.8 9.1 1 11.1 6.5 0.4 0 0.4 0.4 19 5 20 305 34 0 34 0 -18 0 -17.9 -18.1 02/26/2005 18:20:00 9.2 0.8 11.1 6.8 9.1 0.8 11.1 6.8 0.4 0 0.4 0.4 20 5 17 305 33 0 33 0 -17.9 0 -17.7 -18.1 02/26/2005 18:30:00 9.5 1 11.8 6.8 9.4 1.1 12.2 6.8 0.4 0 0.4 0.4 18 5 16 305 33 0 33 0 -17.9 0 -17.5 -18.1 02/26/2005 18:40:00 8.8 0.9 11.1 6.1 8.7 0.9 10.7 6.5 0.4 0 0.4 0.4 17 6 22 305 33 0 33 0 -17.9 0.1 -17.5 -18.1 02/26/2005 18:50:00 8.3 1 10.7 5.7 8.3 0.9 10.7 6.1 0.4 0 0.4 0.4 16 6 14 305 33 0 33 0 -17.8 0 -17.5 -18.1 02/26/2005 19:00:00 9.9 1.2 12.2 6.8 9.9 1.2 12.2 6.8 0.4 0 0.4 0.4 18 4 17 305 33 0 33 0 -17.9 0.1 -17.3 -18.1 02/26/2005 19:10:00 9 1 11.5 7.2 8.9 1 11.5 6.8 0.4 0 0.4 0.4 21 5 22 305 32 0 32 0 -18.1 0 -17.9 -18.2 02/26/2005 19:20:00 9.9 0.9 11.8 7.2 9.9 0.9 11.5 7.2 0.4 0 0.4 0.4 20 5 14 305 32 0 32 0 -18.3 0.1 -18.1 -18.4 02/26/2005 19:30:00 9.1 1.1 11.8 6.1 9.1 1.1 12.2 6.5 0.4 0 0.4 0.4 19 6 18 305 31 0 32 0 -18.5 0 -18.2 -18.4 02/26/2005 19:40:00 10.4 1 12.2 6.8 10.2 1 12.2 7.2 0.4 0 0.4 0.4 21 5 27 305 31 0 31 0 -18.4 0 -18.2 -18.4 02/26/2005 19:50:00 10.6 0.9 12.6 8 10.2 1 12.6 7.6 0.4 0 0.4 0.4 25 5 23 305 30 0 30 0 -18.5 0 -18.1 -18.6 02/26/2005 20:00:00 10.6 0.9 13 8.4 10.4 1 13 8 0.4 0 0.4 0.4 24 5 22 305 30 0 30 0 -18.5 0 -18.1 -18.6 02/26/2005 20:10:00 10.4 1.1 12.6 6.8 10.2 1.1 12.6 7.6 0.4 0 0.4 0.4 25 5 19 305 30 0 29 0 -18.6 0 -18.2 -18.6 02/26/2005 20:20:00 9.5 1.1 12.2 7.2 9.3 1.1 12.6 6.8 0.4 0 0.4 0.4 22 6 20 305 29 0 29 0 -18.5 0 -18.1 -18.6 02/26/2005 20:30:00 10 1 12.6 8 9.9 1 12.2 7.6 0.4 0 0.4 0.4 24 5 19 305 29 0 29 0 -18.6 0 -18.2 -18.8 02/26/2005 20:40:00 10.1 1 12.2 7.2 9.8 1 11.8 6.8 0.4 0 0.4 0.4 25 5 27 305 29 0 29 0 -18.7 0 -18.4 -19 02/26/2005 20:50:00 10.3 0.8 12.2 8 10.1 0.8 12.2 8 0.4 0 0.4 0.4 24 5 18 305 29 0 29 0 -18.8 0 -18.4 -19 02/26/2005 21:00:00 10.1 0.9 12.2 7.2 9.9 0.9 11.8 7.6 0.4 0 0.4 0.4 23 5 22 305 29 0 29 0 -18.7 0 -18.4 -19 02/26/2005 21:10:00 10.3 0.9 12.2 7.2 10.1 1 11.8 7.2 0.4 0 0.4 0.4 22 5 23 305 29 0 29 0 -18.7 0 -18.4 -19 02/26/2005 21:20:00 9.2 1 11.5 6.8 9.1 1 11.5 6.8 0.4 0 0.4 0.4 21 6 12 305 29 0 28 0 -18.7 0 -18.4 -19 02/26/2005 21:30:00 10.2 0.8 11.8 8.4 9.9 0.8 12.2 8 0.4 0 0.4 0.4 24 4 17 305 28 0 28 0 -18.8 0 -18.4 -19 02/26/2005 21:40:00 9.6 0.7 11.1 6.8 9.3 0.8 10.7 6.8 0.4 0 0.4 0.4 24 4 26 305 28 0 28 0 -18.8 0 -18.4 -19 02/26/2005 21:50:00 9 0.7 11.1 6.8 8.9 0.9 11.1 6.5 0.4 0 0.4 0.4 20 5 16 305 28 0 28 0 -18.8 0 -18.4 -19 02/26/2005 22:00:00 8.7 0.8 10.3 5.7 8.5 0.8 10.3 6.1 0.4 0 0.4 0.4 23 5 18 305 28 0 28 0 -18.6 0 -18.2 -18.8 02/26/2005 22:10:00 9.1 0.7 10.7 6.8 8.9 0.7 10.7 6.5 0.4 0 0.4 0.4 22 6 23 305 28 0 28 0 -18.6 0 -18.4 -18.8 02/26/2005 22:20:00 8.8 0.9 11.1 6.8 8.6 0.9 10.7 6.5 0.4 0 0.4 0.4 22 6 25 305 29 0 28 0 -18.6 0 -18.4 -18.8 02/26/2005 22:30:00 9.1 0.9 10.7 5.7 9 0.9 11.1 5.7 0.4 0 0.4 0.4 20 5 18 305 29 0 28 0 -18.6 0 -18.4 -18.8 02/26/2005 22:40:00 8.5 1 10.3 5.7 8.4 1.1 10.3 5.3 0.4 0 0.4 0.4 22 5 23 305 29 0 28 0 -18.7 0 -18.4 -19 02/26/2005 22:50:00 9.3 0.7 11.1 6.8 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 24 5 22 305 29 0 29 0 -18.8 0 -18.6 -19 02/26/2005 23:00:00 8.7 0.8 10.3 6.1 8.5 0.8 9.9 6.5 0.4 0 0.4 0.4 24 4 24 305 28 0 28 0 -18.8 0 -18.6 -19 02/26/2005 23:10:00 8.3 1 10.7 6.1 8.1 1 10.3 6.1 0.4 0 0.4 0.4 25 5 23 305 28 0 28 0 -18.7 0 -18.4 -18.8 02/26/2005 23:20:00 8.6 0.8 10.3 6.5 8.3 0.8 9.9 6.5 0.4 0 0.4 0.4 29 5 29 305 28 0 28 0 -18.8 0 -18.6 -19 02/26/2005 23:30:00 8 0.8 9.9 6.1 7.8 0.8 9.9 5.7 0.4 0 0.4 0.4 26 7 32 305 28 0 28 0 -18.8 0 -18.4 -19 02/26/2005 23:40:00 8 0.8 10.3 6.1 7.9 0.9 10.7 6.1 0.4 0 0.4 0.4 20 6 13 305 28 0 28 0 -18.8 0 -18.6 -19 02/26/2005 23:50:00 8 1 10.3 5.7 8 1 10.3 4.9 0.4 0 0.4 0.4 18 6 16 305 28 0 28 0 -18.9 0 -18.6 -19 02/27/2005 00:00:00 8 0.7 9.9 6.1 8.1 0.8 9.9 5.7 0.4 0 0.4 0.4 15 6 18 305 28 0 28 0 -18.8 0 -18.4 -19 02/27/2005 00:10:00 7.3 0.7 9.1 5.7 7.2 0.7 9.1 5.3 0.4 0 0.4 0.4 12 5 7 305 28 0 28 0 -18.9 0.1 -18.6 -19 02/27/2005 00:20:00 8.1 1 10.3 5.7 8 1 10.3 5.7 0.4 0 0.4 0.4 15 5 14 305 28 0 28 0 -19 0.1 -18.6 -19 02/27/2005 00:30:00 8.5 0.8 10.3 6.1 8.5 0.8 10.3 6.5 0.4 0 0.4 0.4 15 4 6 305 28 0 28 0 -19 0 -18.6 -19 02/27/2005 00:40:00 8.5 0.9 10.7 6.1 8.4 0.9 10.3 6.1 0.4 0 0.4 0.4 17 5 19 305 27 0 27 0 -19.1 0 -18.8 -19.2 02/27/2005 00:50:00 7.8 1.2 9.9 4.6 7.7 1.3 10.7 5.3 0.4 0 0.4 0.4 23 5 27 305 27 0 27 0 -19.2 0 -19 -19.3 02/27/2005 01:00:00 8 1 10.3 6.1 7.9 1 10.3 5.3 0.4 0 0.4 0.4 18 6 16 305 27 0 27 0 -19.2 0 -19 -19.3 02/27/2005 01:10:00 7.8 0.9 9.9 6.1 7.7 0.9 9.9 5.7 0.4 0 0.4 0.4 19 6 21 305 27 0 27 0 -19.3 0 -19 -19.5 02/27/2005 01:20:00 8.8 0.8 11.1 6.5 8.8 0.9 11.1 6.1 0.4 0 0.4 0.4 13 4 12 305 27 0 27 0 -19.4 0.1 -19 -19.5 02/27/2005 01:30:00 8.3 0.8 9.9 6.1 8.3 0.8 10.3 6.1 0.4 0 0.4 0.4 12 4 13 305 26 0 26 0 -19.4 0.1 -19 -19.5 02/27/2005 01:40:00 8.3 0.8 9.9 6.1 8.3 0.9 10.3 6.5 0.4 0 0.4 0.4 20 5 17 305 26 0 26 0 -19.5 0.1 -19 -19.5 02/27/2005 01:50:00 8.4 0.8 10.3 6.5 8.2 0.8 10.3 6.1 0.4 0 0.4 0.4 17 5 15 305 26 0 26 0 -19.5 0.1 -19.2 -19.5 02/27/2005 02:00:00 7.8 1 9.9 5.7 7.7 0.9 9.9 5.7 0.4 0 0.4 0.4 17 5 18 305 26 0 26 0 -19.5 0 -19.2 -19.5 02/27/2005 02:10:00 7.5 0.8 9.1 5.7 7.4 0.8 9.1 5.3 0.4 0 0.4 0.4 14 5 13 305 26 0 26 0 -19.6 0 -19.2 -19.7 02/27/2005 02:20:00 8.2 0.7 9.9 6.5 8.2 0.7 10.3 6.1 0.4 0 0.4 0.4 13 4 9 305 25 0 25 0 -19.5 0 -19.2 -19.5 02/27/2005 02:30:00 8.1 0.8 9.9 6.1 8.1 0.9 9.9 5.7 0.4 0 0.4 0.4 16 5 15 305 25 0 25 0 -19.6 0 -19.3 -19.5 02/27/2005 02:40:00 8.5 0.9 10.3 6.5 8.4 0.9 10.3 6.1 0.4 0 0.4 0.4 18 5 11 305 25 0 25 0 -19.6 0 -19.3 -19.7 02/27/2005 02:50:00 8.1 1 10.3 5.7 8 1 10.3 4.9 0.4 0 0.4 0.4 16 4 27 305 25 0 25 0 -19.6 0 -19.3 -19.9 02/27/2005 03:00:00 8 0.7 9.9 6.1 7.9 0.8 10.3 6.1 0.4 0 0.4 0.4 17 5 17 305 25 0 25 0 -19.8 0 -19.5 -19.9 02/27/2005 03:10:00 8.5 0.7 9.9 6.8 8.3 0.7 9.5 6.5 0.4 0 0.4 0.4 19 4 15 305 25 0 25 0 -19.9 0 -19.5 -20.1 02/27/2005 03:20:00 8.6 1 10.7 6.1 8.4 1 10.7 6.1 0.4 0 0.4 0.4 16 5 16 305 24 0 24 0 -20 0.1 -19.5 -20.1 02/27/2005 03:30:00 9.8 1 11.8 7.6 9.6 1 11.8 6.8 0.4 0 0.4 0.4 18 5 22 305 24 0 24 0 -20.2 0 -20.1 -20.4 02/27/2005 03:40:00 8.5 1 10.7 5.7 8.4 1 10.7 5.7 0.4 0 0.4 0.4 18 5 22 305 23 0 24 0 -20.3 0 -20.1 -20.4 02/27/2005 03:50:00 8.9 0.8 10.7 6.5 8.8 0.9 11.1 6.5 0.4 0 0.4 0.4 15 5 18 305 23 0 23 0 -20.3 0 -20.1 -20.4 02/27/2005 04:00:00 8.7 1 10.7 6.1 8.7 1 10.7 6.1 0.4 0 0.4 0.4 14 5 12 305 23 0 23 0 -20.2 0 -20.1 -20.4 02/27/2005 04:10:00 8.8 0.7 10.3 6.5 8.5 0.8 10.3 6.5 0.4 0 0.4 0.4 17 5 16 305 23 0 23 0 -20.2 0 -20.1 -20.4 02/27/2005 04:20:00 8.7 0.8 10.3 6.5 8.6 0.8 10.3 6.5 0.4 0 0.4 0.4 17 5 11 305 23 0 23 0 -20.3 0 -20.1 -20.6 02/27/2005 04:30:00 9.6 1 12.2 6.8 9.6 1 11.8 7.2 0.4 0 0.4 0.4 14 5 16 305 22 0 22 0 -20.5 0.1 -20.2 -20.8 02/27/2005 04:40:00 9.9 0.9 11.8 8 9.7 0.9 11.8 7.6 0.4 0 0.4 0.4 17 6 18 305 22 0 22 0 -20.6 0.1 -20.2 -20.8 02/27/2005 04:50:00 9.9 0.7 11.8 7.6 9.8 0.7 11.5 7.6 0.4 0 0.4 0.4 21 4 17 305 22 0 22 0 -20.6 0 -20.4 -20.8 02/27/2005 05:00:00 9.4 1.2 12.6 6.5 9.2 1.2 12.2 6.8 0.4 0 0.4 0.4 21 5 16 305 22 0 22 0 -20.6 0 -20.4 -20.8 02/27/2005 05:10:00 10.7 1.5 14.1 6.8 10.5 1.5 15.3 7.2 0.4 0 0.4 0.4 25 6 18 305 22 0 22 0 -20.4 0.1 -20.1 -20.6 02/27/2005 05:20:00 10.7 1.2 13.7 7.6 10.6 1.2 13 7.6 0.4 0 0.4 0.4 22 6 25 305 22 0 22 0 -20.2 0 -20.1 -20.2 02/27/2005 05:30:00 10.7 1.1 14.1 8 10.5 1.1 13 8 0.4 0 0.4 0.4 25 6 17 305 22 0 22 0 -20.3 0 -20.1 -20.6 02/27/2005 05:40:00 10 1.2 13 7.6 9.9 1.2 13 7.2 0.4 0 0.4 0.4 22 6 29 305 22 0 22 0 -20.2 0 -20.1 -20.4 02/27/2005 05:50:00 10.6 1.2 13.3 7.6 10.4 1.3 13.3 7.6 0.4 0 0.4 0.4 21 5 15 305 22 0 22 0 -20.2 0 -20.1 -20.2 02/27/2005 06:00:00 11.2 0.9 13.3 8.8 11 1 13.7 8.8 0.4 0 0.4 0.4 21 5 20 305 22 0 22 0 -20.2 0 -20.1 -20.4 02/27/2005 06:10:00 10.8 0.9 13.7 8 10.6 1 13.3 8 0.4 0 0.4 0.4 19 5 16 305 22 0 22 0 -20.2 0 -20.1 -20.2 02/27/2005 06:20:00 10.9 1.1 13.7 8.4 10.7 1.1 13 7.6 0.4 0 0.4 0.4 19 5 21 305 22 0 22 0 -20.3 0 -20.1 -20.6 02/27/2005 06:30:00 11.1 1.1 13.3 8 11 1.1 13.3 8 0.4 0 0.4 0.4 18 4 15 305 22 0 22 0 -20.3 0 -20.1 -20.6 02/27/2005 06:40:00 10.3 1.1 13 7.2 10.2 1 12.6 7.6 0.4 0 0.4 0.4 21 6 20 305 22 0 22 0 -20.4 0 -20.1 -20.6 02/27/2005 06:50:00 10.3 1.2 12.6 6.8 10.2 1.3 13.3 6.8 0.4 0 0.4 0.4 17 5 14 305 22 0 22 0 -20.3 0 -20.1 -20.4 02/27/2005 07:00:00 10 1 12.6 8 9.9 1 12.6 7.2 0.4 0 0.4 0.4 17 5 21 305 22 0 22 0 -20.2 0 -20.1 -20.2 02/27/2005 07:10:00 10.4 1.3 14.1 7.6 10.2 1.3 14.1 7.6 0.4 0 0.4 0.4 18 6 13 305 22 0 22 0 -20.2 0 -19.9 -20.4 02/27/2005 07:20:00 10.9 1.1 13.3 8.8 10.8 1.2 13.3 8 0.4 0 0.4 0.4 17 5 21 305 22 0 22 0 -20.2 0 -19.9 -20.2 02/27/2005 07:30:00 10.8 1 13.3 8.4 10.7 1 13.3 8 0.4 0 0.4 0.4 17 4 15 305 22 0 22 0 -20.2 0 -20.1 -20.4 02/27/2005 07:40:00 10.3 1 12.6 8 10.2 1 13 7.2 0.4 0 0.4 0.4 18 6 10 305 22 0 22 0 -20.3 0 -20.1 -20.4 02/27/2005 07:50:00 10.1 0.8 12.6 8 9.9 0.8 12.6 8 0.4 0 0.4 0.4 20 5 17 305 22 0 22 0 -20.3 0 -20.1 -20.6 02/27/2005 08:00:00 11.4 1 13.7 8.8 11.4 1 14.1 9.1 0.4 0 0.4 0.4 17 5 18 305 22 0 22 0 -20.4 0 -20.1 -20.6 02/27/2005 08:10:00 11.1 1 14.1 8.8 11 1.1 14.1 8.4 0.4 0 0.4 0.4 18 6 24 305 22 0 22 0 -20.4 0 -20.1 -20.6 02/27/2005 08:20:00 12.1 1.2 14.9 8.4 11.9 1.3 14.5 8 0.4 0 0.4 0.4 21 5 16 305 22 0 22 0 -20.3 0 -20.1 -20.6 02/27/2005 08:30:00 10.7 1.3 13.3 7.6 10.6 1.3 13 7.2 0.4 0 0.4 0.4 26 5 26 305 22 0 22 0 -20.3 0 -20.1 -20.6 02/27/2005 08:40:00 10.8 1.2 14.1 7.6 10.7 1.2 14.1 8 0.4 0 0.4 0.4 23 6 26 305 22 0 22 0 -20.4 0 -20.1 -20.6 02/27/2005 08:50:00 11.9 1.5 15.6 8.4 11.7 1.4 14.9 8.4 0.4 0 0.4 0.4 14 6 10 305 22 0 22 0 -20.4 0 -20.1 -20.6 02/27/2005 09:00:00 11.5 1.2 14.5 8.8 11.4 1.2 14.5 8.4 0.4 0 0.4 0.4 16 5 15 305 22 0 22 0 -20.5 0 -20.1 -20.8 02/27/2005 09:10:00 11.1 1.2 13.7 7.6 11 1.2 14.1 8 0.4 0 0.4 0.4 18 5 21 305 22 0 22 0 -20.5 0 -20.2 -20.8 02/27/2005 09:20:00 9.7 1.4 13.3 6.8 9.5 1.4 13.7 6.5 0.4 0 0.4 0.4 23 8 29 305 22 0 22 0 -20.5 0 -20.2 -20.6 02/27/2005 09:30:00 10.4 1.4 13.7 7.2 10.1 1.5 13.7 6.8 0.4 0 0.4 0.4 26 7 26 305 22 0 22 0 -20.6 0.1 -20.2 -20.8 02/27/2005 09:40:00 11.4 1 13.7 9.1 11.3 1.1 13.7 8.8 0.4 0 0.4 0.4 21 5 25 305 22 0 22 0 -20.7 0 -20.6 -20.8 02/27/2005 09:50:00 11.3 1.1 14.1 8.8 11.2 1.2 14.1 8.8 0.4 0 0.4 0.4 19 5 16 305 21 0 21 0 -20.8 0 -20.8 -21 02/27/2005 10:00:00 10.4 1.1 13 6.8 10.2 1.1 13.3 7.2 0.4 0 0.4 0.4 23 6 23 305 21 0 21 0 -20.7 0 -20.6 -21 02/27/2005 10:10:00 9.7 1.1 12.6 7.2 9.5 1.2 12.6 6.8 0.4 0 0.4 0.4 20 5 24 305 21 0 21 0 -20.9 0 -20.6 -21 02/27/2005 10:20:00 10.2 1 12.2 7.2 10 1 12.6 7.2 0.4 0 0.4 0.4 20 6 24 305 21 0 21 0 -20.8 0 -20.8 -21 02/27/2005 10:30:00 9.5 1.3 13 6.5 9.5 1.3 13 6.5 0.4 0 0.4 0.4 14 6 27 305 21 0 21 0 -20.7 0 -20.6 -21 02/27/2005 10:40:00 13 1.1 15.6 9.1 13 1.2 15.6 9.1 0.4 0 0.4 0.4 4 5 2 305 21 0 21 0 -20.5 0.1 -20.1 -20.8 02/27/2005 10:50:00 12.3 1 14.9 9.5 12.2 1.1 14.9 9.9 0.4 0 0.4 0.4 3 5 1 305 22 0 22 0 -20.3 0 -20.1 -20.6 02/27/2005 11:00:00 8.9 1.9 12.6 5.3 8.8 2 12.2 5.3 0.4 0 0.4 0.4 19 12 13 305 22 0 22 0 -20.3 0 -20.1 -20.6 02/27/2005 11:10:00 7.9 1.3 10.7 4.9 7.7 1.5 11.1 4.2 0.4 0 0.4 0.4 21 10 7 305 24 0 25 0 -20.3 0 -20.1 -20.6 02/27/2005 11:20:00 9.2 1.1 11.1 6.1 9.1 1.1 11.1 6.1 0.4 0 0.4 0.4 10 6 6 305 25 0 25 0 -20.3 0 -20.1 -20.4 02/27/2005 11:30:00 8.9 0.8 10.7 6.5 8.8 0.9 10.7 6.5 0.4 0 0.4 0.4 12 5 15 305 25 0 25 0 -20.2 0 -19.9 -20.4 02/27/2005 11:40:00 9 1 11.1 6.8 8.9 1 11.5 6.8 0.4 0 0.4 0.4 13 5 8 305 26 0 26 0 -20.2 0 -19.9 -20.4 02/27/2005 11:50:00 9.1 0.9 11.1 6.5 9 1 11.5 6.5 0.4 0 0.4 0.4 14 6 11 305 26 0 25 0 -20.2 0 -20.1 -20.4 02/27/2005 12:00:00 8.5 0.9 11.1 6.1 8.4 0.8 10.7 6.5 0.4 0 0.4 0.4 12 5 16 305 26 0 26 0 -20.2 0 -19.9 -20.4 02/27/2005 12:10:00 7 0.8 9.1 4.9 6.9 0.8 9.1 5.3 0.4 0 0.4 0.4 13 6 8 305 27 0 26 0 -20.2 0 -19.7 -20.2 02/27/2005 12:20:00 8.4 0.9 10.7 6.1 8.3 1 10.3 5.7 0.4 0 0.4 0.4 10 5 17 305 28 0 28 0 -20.1 0.1 -19.5 -20.1 02/27/2005 12:30:00 7.3 0.8 9.1 5.3 7.1 0.9 9.1 4.9 0.4 0 0.4 0.4 20 5 23 305 28 0 28 0 -20 0.1 -19.5 -20.1 02/27/2005 12:40:00 7.1 0.9 9.1 4.9 7 0.8 9.1 5.3 0.4 0 0.4 0.4 17 5 16 305 29 0 29 0 -19.8 0 -19.5 -20.1 02/27/2005 12:50:00 7.5 0.7 9.1 5.3 7.3 0.8 9.1 4.9 0.4 0 0.4 0.4 16 7 23 305 30 0 31 0 -19.7 0.1 -19.3 -20.1 02/27/2005 13:00:00 7.6 1 9.5 4.6 7.6 1 9.5 4.6 0.4 0 0.4 0.4 3 5 3 305 31 0 31 0 -19.6 0 -19 -19.5 02/27/2005 13:10:00 7 0.8 8.8 4.9 6.8 0.8 8.8 4.6 0.4 0 0.4 0.4 14 6 12 305 31 0 31 0 -19.4 0.1 -19 -19.5 02/27/2005 13:20:00 7.9 0.9 9.5 5.3 7.8 0.9 9.5 5.7 0.4 0 0.4 0.4 8 5 11 305 32 0 32 0 -19.4 0.1 -19 -19.5 02/27/2005 13:30:00 8.6 0.9 10.7 6.5 8.6 0.9 10.7 6.1 0.4 0 0.4 0.4 6 5 9 305 31 0 31 0 -19.4 0.1 -19 -19.5 02/27/2005 13:40:00 9.1 0.7 10.7 7.2 9 0.7 10.7 7.2 0.4 0 0.4 0.4 7 4 6 305 31 0 31 0 -19.3 0 -19 -19.5 02/27/2005 13:50:00 7.9 0.8 9.9 5.7 7.8 0.9 9.9 5.7 0.4 0 0.4 0.4 10 5 10 305 31 0 31 0 -19.2 0 -18.6 -19.3 02/27/2005 14:00:00 8.3 0.7 9.9 6.1 8.2 0.8 9.9 5.7 0.4 0 0.4 0.4 9 5 8 305 31 0 31 0 -19.1 0 -18.6 -19.2 02/27/2005 14:10:00 6.9 1.1 9.1 4.6 6.9 1.1 9.5 4.6 0.4 0 0.4 0.4 14 7 13 305 32 0 32 0 -18.9 0.1 -18.4 -19 02/27/2005 14:20:00 6.6 0.9 8.8 4.6 6.6 0.8 9.1 4.9 0.4 0 0.4 0.4 17 6 14 305 33 0 34 0 -18.7 0.1 -18.2 -19 02/27/2005 14:30:00 7.8 0.9 9.9 4.6 7.7 0.9 9.9 4.9 0.4 0 0.4 0.4 15 5 7 305 35 0 35 0 -18.7 0 -18.4 -19 02/27/2005 14:40:00 8.1 1.1 10.7 5.3 8 1.1 10.3 5.3 0.4 0 0.4 0.4 16 5 14 305 35 0 35 0 -18.6 0 -18.1 -18.8 02/27/2005 14:50:00 8 1 10.3 5.7 8 1.1 10.7 5.3 0.4 0 0.4 0.4 14 7 22 305 35 0 35 0 -18.5 0.1 -18.1 -18.6 02/27/2005 15:00:00 8.5 0.8 9.9 6.5 8.4 0.8 10.3 6.5 0.4 0 0.4 0.4 21 4 18 305 36 0 37 0 -18.4 0.1 -17.9 -18.4 02/27/2005 15:10:00 8.6 1.1 11.1 6.1 8.4 1 11.1 6.1 0.4 0 0.4 0.4 17 6 9 305 38 0 38 0 -18.3 0.1 -17.9 -18.6 02/27/2005 15:20:00 8.3 1 11.8 6.5 8.1 1 10.7 5.7 0.4 0 0.4 0.4 15 7 5 305 39 0 38 0 -18.1 0 -17.7 -18.4 02/27/2005 15:30:00 7.8 0.9 9.5 5.7 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 14 7 22 305 39 0 39 0 -18.1 0.1 -17.5 -18.4 02/27/2005 15:40:00 9.5 1.4 12.6 5.7 9.4 1.4 13 6.1 0.4 0 0.4 0.4 8 7 7 305 40 0 40 0 -17.9 0.1 -17.5 -18.1 02/27/2005 15:50:00 9.8 0.9 12.2 7.2 9.7 1 12.6 6.8 0.4 0 0.4 0.4 10 6 8 305 40 0 40 0 -18.3 0.2 -17.7 -18.4 02/27/2005 16:00:00 9.8 1 12.2 7.6 9.9 1.1 13 7.2 0.4 0 0.4 0.4 7 5 359 305 38 1 36 0 -18.1 0.2 -17.5 -18.4 02/27/2005 16:10:00 11.2 1 13 8.4 11.3 1.1 13.7 8.4 0.4 0 0.4 0.4 7 4 7 305 37 0 36 0 -18 0 -17.5 -18.1 02/27/2005 16:20:00 8.9 1.2 11.1 6.1 8.9 1.2 11.1 6.1 0.4 0 0.4 0.4 7 5 5 305 39 0 38 0 -17.9 0.1 -17.5 -18.1 02/27/2005 16:30:00 9 0.9 11.8 6.8 9 1 11.5 6.5 0.4 0 0.4 0.4 8 6 17 305 40 0 40 0 -17.9 0.1 -17.5 -18.1 02/27/2005 16:40:00 8.5 0.9 10.7 6.5 8.4 1 11.1 6.5 0.4 0 0.4 0.4 16 5 20 305 42 0 41 0 -17.8 0.1 -17.3 -18.1 02/27/2005 16:50:00 7.1 1.2 9.5 3.8 7.1 1.2 9.9 4.2 0.4 0 0.4 0.4 16 7 25 305 43 0 43 0 -17.7 0.1 -17.3 -17.9 02/27/2005 17:00:00 7 1.3 11.1 4.6 7 1.3 11.1 4.9 0.4 0 0.4 0.4 9 9 354 305 45 0 45 0 -17.7 0.1 -17.1 -17.9 02/27/2005 17:10:00 9.1 0.8 11.5 6.8 9.1 0.8 11.5 6.5 0.4 0 0.4 0.4 13 6 18 305 46 0 46 0 -17.8 0.1 -17.3 -18.1 02/27/2005 17:20:00 7.6 0.9 10.7 5.7 7.6 0.9 11.1 6.1 0.4 0 0.4 0.4 12 8 7 305 46 0 46 0 -17.8 0.1 -17.3 -18.1 02/27/2005 17:30:00 6.7 0.8 9.1 4.6 6.7 0.8 8.4 4.6 0.4 0 0.4 0.4 23 13 22 305 46 0 46 0 -17.7 0.1 -17.1 -17.9 02/27/2005 17:40:00 7.9 0.8 9.9 6.1 7.9 0.8 9.9 5.7 0.4 0 0.4 0.4 13 6 12 305 47 0 47 0 -17.6 0.1 -17.1 -18.1 02/27/2005 17:50:00 7.7 0.7 9.5 6.1 7.7 0.6 9.5 5.7 0.4 0 0.4 0.4 17 8 19 305 47 0 47 0 -17.7 0.1 -17.1 -17.9 02/27/2005 18:00:00 7.6 1 10.3 4.9 7.5 0.9 9.5 5.3 0.4 0 0.4 0.4 16 6 3 305 46 0 46 0 -17.8 0.1 -17.3 -18.1 02/27/2005 18:10:00 7.8 0.7 10.3 6.1 7.6 0.8 9.1 5.3 0.4 0 0.4 0.4 27 8 29 305 45 1 45 0 -17.8 0.1 -17.3 -18.1 02/27/2005 18:20:00 8 1.5 11.8 4.9 7.9 1.6 11.5 4.6 0.4 0 0.4 0.4 13 15 357 305 42 0 42 0 -17.5 0.2 -16.9 -17.9 02/27/2005 18:30:00 7.2 1 10.7 5.3 7.2 1 10.7 5.3 0.4 0 0.4 0.4 8 7 358 305 43 0 43 0 -17.5 0.1 -16.9 -17.7 02/27/2005 18:40:00 7.1 0.8 9.1 5.3 6.9 0.8 9.1 4.9 0.4 0 0.4 0.4 23 6 21 305 42 0 42 0 -17.6 0 -17.1 -17.9 02/27/2005 18:50:00 8.3 1.2 11.8 5.7 8.2 1.2 11.8 5.7 0.4 0 0.4 0.4 24 12 4 305 41 0 40 0 -17.6 0 -17.3 -17.9 02/27/2005 19:00:00 9.4 1.1 11.8 7.2 9.4 1 11.8 6.5 0.4 0 0.4 0.4 12 7 23 305 40 0 41 0 -17.6 0.1 -17.1 -17.9 02/27/2005 19:10:00 10.8 0.9 13.3 8.4 10.8 0.9 13.3 8.8 0.4 0 0.4 0.4 10 5 8 305 39 1 39 0 -17.5 0.1 -16.9 -17.9 02/27/2005 19:20:00 10.1 1.5 13.3 6.8 10 1.5 13.7 6.8 0.4 0 0.4 0.4 16 13 0 305 36 1 37 0 -17.8 0.2 -17.3 -18.2 02/27/2005 19:30:00 9.5 1.3 13 6.8 9.1 1.1 12.2 6.5 0.4 0 0.4 0.4 27 8 35 305 33 0 33 0 -18.1 0.1 -17.5 -18.2 02/27/2005 19:40:00 9.4 1.1 11.8 6.8 9.1 1.1 11.8 6.5 0.4 0 0.4 0.4 28 8 27 305 32 0 32 0 -18.1 0 -17.5 -18.2 02/27/2005 19:50:00 8.5 1 10.7 5.3 8.4 1 10.7 5.7 0.4 0 0.4 0.4 32 6 30 305 31 0 31 0 -18.3 0.1 -17.9 -18.4 02/27/2005 20:00:00 8.9 0.8 11.1 6.8 8.6 0.8 11.1 6.8 0.4 0 0.4 0.4 30 6 32 305 30 0 30 0 -18.6 0 -18.2 -18.8 02/27/2005 20:10:00 9.1 0.9 11.1 6.1 9 0.9 11.1 6.8 0.4 0 0.4 0.4 23 6 30 305 29 0 29 0 -18.7 0.1 -18.4 -19 02/27/2005 20:20:00 10 1.2 12.6 6.5 10 1.3 12.6 6.5 0.4 0 0.4 0.4 16 7 16 305 29 0 29 0 -18.7 0 -18.4 -19 02/27/2005 20:30:00 9.6 1.3 13 5.7 9.5 1.3 13.3 5.7 0.4 0 0.4 0.4 15 8 7 305 28 0 28 0 -18.8 0 -18.4 -19 02/27/2005 20:40:00 9.6 1.3 12.2 6.1 9.4 1.3 13 6.1 0.4 0 0.4 0.4 19 7 14 305 28 0 27 0 -18.9 0.1 -18.4 -19 02/27/2005 20:50:00 11 1.2 13.3 7.6 10.9 1.1 13.7 8.4 0.4 0 0.4 0.4 11 5 4 305 27 0 27 0 -18.9 0.1 -18.4 -19 02/27/2005 21:00:00 9.5 1.2 12.2 6.8 9.4 1.1 11.8 6.5 0.4 0 0.4 0.4 18 6 22 305 27 0 27 0 -19 0.1 -18.4 -19 02/27/2005 21:10:00 10.5 1 13.3 8 10.5 1 13.3 7.6 0.4 0 0.4 0.4 14 5 9 305 27 0 26 0 -19.2 0 -18.8 -19.3 02/27/2005 21:20:00 10.7 0.8 13 8.4 10.6 0.8 12.2 8.8 0.4 0 0.4 0.4 14 4 8 305 26 0 26 0 -19.4 0 -19 -19.5 02/27/2005 21:30:00 11.1 0.9 13 8.4 11.1 1 13 8 0.4 0 0.4 0.4 10 4 11 305 25 0 25 0 -19.5 0.1 -19.2 -19.5 02/27/2005 21:40:00 11.2 0.8 13 8.8 11 0.9 13 8.4 0.4 0 0.4 0.4 13 4 14 305 25 0 25 0 -19.5 0 -19.2 -19.5 02/27/2005 21:50:00 11.1 1 13 7.6 11.2 1 13 8.4 0.4 0 0.4 0.4 13 4 14 305 25 0 25 0 -19.5 0.1 -19.2 -19.5 02/27/2005 22:00:00 9.6 1.3 12.2 6.5 9.5 1.3 11.8 6.8 0.4 0 0.4 0.4 13 5 9 305 25 0 24 0 -19.5 0 -19.2 -19.7 02/27/2005 22:10:00 9.2 1 11.5 7.2 9.1 1 11.8 7.2 0.4 0 0.4 0.4 13 4 14 305 25 0 25 0 -19.6 0 -19.3 -19.5 02/27/2005 22:20:00 8.5 1 10.7 6.1 8.4 1 10.7 6.1 0.4 0 0.4 0.4 15 6 14 305 24 0 24 0 -19.6 0 -19.3 -19.7 02/27/2005 22:30:00 8.4 0.9 10.7 5.7 8.3 1 10.7 5.7 0.4 0 0.4 0.4 13 5 15 305 24 0 24 0 -19.6 0 -19.3 -19.7 02/27/2005 22:40:00 8.1 1 10.7 5.7 8 0.9 11.5 6.1 0.4 0 0.4 0.4 12 5 14 305 24 0 24 0 -19.7 0 -19.3 -19.9 02/27/2005 22:50:00 7.9 1 10.3 5.7 7.9 1 9.9 5.7 0.4 0 0.4 0.4 18 5 23 305 24 0 24 0 -19.7 0 -19.5 -19.9 02/27/2005 23:00:00 8.4 0.8 9.9 6.1 8.2 0.9 9.9 6.5 0.4 0 0.4 0.4 18 5 17 305 24 0 24 0 -19.7 0 -19.5 -19.9 02/27/2005 23:10:00 7.9 0.9 10.3 5.3 7.6 1 10.3 4.9 0.4 0 0.4 0.4 18 5 18 305 24 0 24 0 -19.7 0 -19.5 -19.9 02/27/2005 23:20:00 7.1 1.1 9.1 4.6 7 1.1 9.5 4.6 0.4 0 0.4 0.4 14 5 17 305 24 0 24 0 -19.7 0 -19.5 -19.9 02/27/2005 23:30:00 8 0.9 9.9 5.3 7.9 0.8 9.5 6.1 0.4 0 0.4 0.4 16 5 17 305 24 0 24 0 -19.7 0 -19.5 -19.9 02/27/2005 23:40:00 8.5 0.6 9.5 6.8 8.3 0.6 10.3 6.8 0.4 0 0.4 0.4 13 5 14 305 23 0 24 0 -19.7 0 -19.5 -19.9 02/27/2005 23:50:00 7.2 0.9 9.9 5.3 7.1 0.8 9.5 5.7 0.4 0 0.4 0.4 16 5 14 305 23 0 24 0 -19.7 0 -19.5 -19.9 02/28/2005 00:00:00 7.4 0.9 9.5 4.9 7.4 0.8 9.5 5.3 0.4 0 0.4 0.4 12 5 17 305 23 0 23 0 -19.7 0 -19.3 -19.9 02/28/2005 00:10:00 6.4 0.8 8.4 4.2 6.3 0.8 8 3.8 0.4 0 0.4 0.4 12 5 10 305 23 0 23 0 -19.7 0 -19.5 -19.9 02/28/2005 00:20:00 7.7 0.7 9.1 5.7 7.6 0.7 9.1 5.7 0.4 0 0.4 0.4 14 4 12 305 23 0 24 0 -19.5 0.1 -19.2 -19.7 02/28/2005 00:30:00 7.2 1 9.1 4.9 7.1 1 9.5 4.9 0.4 0 0.4 0.4 12 5 18 305 23 0 23 0 -19.4 0 -19 -19.5 02/28/2005 00:40:00 5.4 0.6 7.2 3.8 5.3 0.6 6.8 3.8 0.4 0 0.4 0.4 7 7 3 305 24 0 24 0 -19.4 0 -19.2 -19.5 02/28/2005 00:50:00 5.8 0.7 8.4 3.8 5.7 0.7 7.6 4.2 0.4 0 0.4 0.4 15 5 9 305 24 0 24 0 -19.5 0.1 -19.2 -19.5 02/28/2005 01:00:00 7 0.9 8.8 4.9 6.9 0.8 8.8 4.9 0.4 0 0.4 0.4 22 6 29 305 24 0 24 0 -19.3 0 -19 -19.5 02/28/2005 01:10:00 7.8 0.8 9.9 5.7 7.6 0.8 9.9 5.3 0.4 0 0.4 0.4 22 6 19 305 24 0 24 0 -19.2 0 -19 -19.5 02/28/2005 01:20:00 7.8 1.1 11.1 5.3 7.5 1.1 10.3 4.9 0.4 0 0.4 0.4 23 7 24 305 24 0 24 0 -19.2 0 -19 -19.3 02/28/2005 01:30:00 8.2 0.9 10.7 5.7 8 0.9 10.7 5.7 0.4 0 0.4 0.4 24 5 31 305 24 0 24 0 -19.1 0 -18.8 -19.2 02/28/2005 01:40:00 7.7 1 10.3 5.3 7.7 1 9.9 5.3 0.4 0 0.4 0.4 19 5 16 305 24 0 24 0 -19.1 0 -18.8 -19.3 02/28/2005 01:50:00 8.7 1.1 11.8 6.5 8.7 1.1 11.5 6.1 0.4 0 0.4 0.4 13 5 13 305 24 0 24 0 -19 0.1 -18.6 -19.2 02/28/2005 02:00:00 9.5 1 11.8 7.2 9.5 1 11.8 6.8 0.4 0 0.4 0.4 15 5 14 305 24 0 24 0 -19 0 -18.6 -19 02/28/2005 02:10:00 9.8 1.2 12.6 6.5 9.6 1.2 12.2 6.5 0.4 0 0.4 0.4 13 5 14 305 25 0 25 0 -19 0 -18.6 -19.2 02/28/2005 02:20:00 9.2 1 11.8 6.8 9.1 1.1 11.8 6.5 0.4 0 0.4 0.4 17 5 17 305 25 0 25 0 -19 0.1 -18.4 -19 02/28/2005 02:30:00 9.8 1.5 13 6.5 9.8 1.5 13.7 6.5 0.4 0 0.4 0.4 17 5 12 305 25 0 25 0 -19.1 0 -18.8 -19.2 02/28/2005 02:40:00 7.8 0.7 9.5 6.5 7.6 0.7 9.9 6.1 0.4 0 0.4 0.4 31 8 24 305 25 0 25 0 -19.3 0.1 -19 -19.5 02/28/2005 02:50:00 7.5 0.6 9.5 5.3 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 30 9 28 305 24 0 25 0 -19.5 0.1 -19.2 -19.5 02/28/2005 03:00:00 9.1 1 12.2 6.8 9.1 1 11.5 6.8 0.4 0 0.4 0.4 19 5 19 305 24 0 24 0 -19.2 0.1 -18.8 -19.5 02/28/2005 03:10:00 10.1 1.2 12.6 7.2 10 1.3 13 7.2 0.4 0 0.4 0.4 17 5 15 305 24 0 25 0 -19.1 0 -18.8 -19.2 02/28/2005 03:20:00 7.5 1.2 11.1 5.3 7.3 1.3 11.1 5.3 0.4 0 0.4 0.4 24 7 8 305 25 0 25 0 -19.2 0.1 -18.8 -19.5 02/28/2005 03:30:00 9 1.6 12.2 5.3 8.7 1.6 11.8 4.9 0.4 0 0.4 0.4 21 8 22 305 25 0 25 0 -19.2 0 -18.8 -19.5 02/28/2005 03:40:00 9.9 1.1 13 7.2 9.9 1.2 13 6.5 0.4 0 0.4 0.4 17 6 17 305 25 0 25 0 -19 0 -18.6 -19 02/28/2005 03:50:00 10.3 1.2 12.6 7.2 10.2 1.2 13 6.8 0.4 0 0.4 0.4 15 5 17 305 25 0 25 0 -19.1 0 -18.6 -19.2 02/28/2005 04:00:00 10.4 1.3 13 7.2 10.2 1.3 13 7.2 0.4 0 0.4 0.4 17 7 17 305 25 0 25 0 -19.2 0.1 -19 -19.5 02/28/2005 04:10:00 8.9 1 11.5 6.5 8.7 0.9 11.1 6.5 0.4 0 0.4 0.4 21 6 23 305 25 0 25 0 -19.4 0.1 -19 -19.5 02/28/2005 04:20:00 9.9 1 12.6 7.2 9.8 1 12.2 7.2 0.4 0 0.4 0.4 20 5 18 305 25 0 25 0 -19.4 0.1 -19 -19.5 02/28/2005 04:30:00 10.4 1 12.6 7.2 10.3 1.1 12.6 7.2 0.4 0 0.4 0.4 13 4 9 305 24 0 24 0 -19.5 0.1 -19.2 -19.5 02/28/2005 04:40:00 9.7 1.2 11.8 6.5 9.4 1.1 11.5 5.7 0.4 0 0.4 0.4 16 5 17 305 24 0 24 0 -19.6 0 -19.2 -19.7 02/28/2005 04:50:00 10.2 0.8 12.2 8 10 1 12.2 7.2 0.4 0 0.4 0.4 15 5 12 305 24 0 24 0 -19.6 0 -19.2 -19.7 02/28/2005 05:00:00 10.2 1.4 13 7.2 10 1.3 13.3 7.2 0.4 0 0.4 0.4 16 5 17 305 24 0 24 0 -19.6 0 -19.3 -19.7 02/28/2005 05:10:00 10 0.9 12.2 7.2 9.8 1 12.2 7.6 0.4 0 0.4 0.4 15 5 13 305 24 0 24 0 -19.6 0 -19.3 -19.7 02/28/2005 05:20:00 10.3 1.2 12.6 6.8 10.2 1.2 12.6 6.8 0.4 0 0.4 0.4 16 5 15 305 24 0 24 0 -19.6 0 -19.3 -19.5 02/28/2005 05:30:00 9.7 1.5 12.6 6.5 9.6 1.6 13 6.5 0.4 0 0.4 0.4 14 6 19 305 24 0 24 0 -19.7 0 -19.3 -19.9 02/28/2005 05:40:00 10.1 1 12.2 7.2 9.9 1 13 6.8 0.4 0 0.4 0.4 18 5 18 305 24 0 24 0 -19.7 0 -19.3 -19.9 02/28/2005 05:50:00 10.2 1.1 12.6 7.6 10 1.1 12.6 7.6 0.4 0 0.4 0.4 18 6 17 305 24 0 24 0 -19.9 0 -19.5 -20.1 02/28/2005 06:00:00 9.8 1 12.6 7.2 9.6 1 12.2 7.2 0.4 0 0.4 0.4 21 5 27 305 23 0 24 0 -20 0.1 -19.5 -20.1 02/28/2005 06:10:00 10.1 0.8 12.2 7.2 10.1 0.9 12.2 7.6 0.4 0 0.4 0.4 21 5 25 305 23 0 23 0 -20.1 0 -19.7 -20.1 02/28/2005 06:20:00 10.7 1 12.6 7.6 10.5 1 13 8 0.4 0 0.4 0.4 19 6 24 305 23 0 23 0 -20.2 0 -19.9 -20.2 02/28/2005 06:30:00 10.4 1.1 13 7.2 10.3 1.2 12.6 7.6 0.4 0 0.4 0.4 19 4 18 305 22 0 22 0 -20.2 0 -19.9 -20.2 02/28/2005 06:40:00 10 1.2 12.6 7.2 9.9 1.2 13 6.8 0.4 0 0.4 0.4 19 5 15 305 22 0 22 0 -20.2 0 -20.1 -20.2 02/28/2005 06:50:00 11.3 0.7 13 8.4 11.1 0.8 13 8.4 0.4 0 0.4 0.4 19 4 22 305 22 0 22 0 -20.2 0 -20.1 -20.2 02/28/2005 07:00:00 10 1.1 12.2 7.6 9.8 1.2 12.2 6.8 0.4 0 0.4 0.4 19 5 20 305 22 0 22 0 -20.2 0 -19.7 -20.2 02/28/2005 07:10:00 8.6 1.1 11.5 5.7 8.4 1 11.1 5.7 0.4 0 0.4 0.4 14 6 5 305 22 0 22 0 -20.1 0 -19.7 -20.1 02/28/2005 07:20:00 9.9 1 11.8 7.2 9.8 1 11.8 7.2 0.4 0 0.4 0.4 20 6 29 305 22 0 22 0 -20.1 0 -19.7 -20.1 02/28/2005 07:30:00 10.6 1 12.6 8 10.5 1 13 7.6 0.4 0 0.4 0.4 17 5 17 305 22 0 22 0 -20.1 0 -19.7 -20.1 02/28/2005 07:40:00 9.1 1.5 12.6 6.5 9 1.5 13 6.5 0.4 0 0.4 0.4 16 6 11 305 22 0 22 0 -20.2 0 -19.9 -20.2 02/28/2005 07:50:00 9.8 1 11.5 7.2 9.7 1 11.8 6.8 0.4 0 0.4 0.4 12 6 11 305 22 0 22 0 -20.2 0 -19.9 -20.2 02/28/2005 08:00:00 8.6 1 10.7 6.5 8.5 1 10.7 5.7 0.4 0 0.4 0.4 15 6 8 305 22 0 22 0 -20.2 0 -19.9 -20.2 02/28/2005 08:10:00 8.7 1 10.7 6.1 8.5 0.9 10.7 6.5 0.4 0 0.4 0.4 14 9 18 305 22 0 22 0 -20.2 0 -19.9 -20.2 02/28/2005 08:20:00 8.8 1.3 11.1 5.7 8.7 1.2 11.5 6.1 0.4 0 0.4 0.4 12 6 11 305 22 0 22 0 -20.2 0 -19.9 -20.2 02/28/2005 08:30:00 8.9 1 11.8 6.5 8.7 1.1 11.1 6.1 0.4 0 0.4 0.4 16 6 23 305 22 0 22 0 -20 0.1 -19.5 -20.1 02/28/2005 08:40:00 9.1 1 12.2 6.8 9 1 12.2 6.8 0.4 0 0.4 0.4 14 6 7 305 22 0 22 0 -19.7 0.1 -19.5 -19.9 02/28/2005 08:50:00 8.7 1.2 11.1 5.7 8.6 1.2 11.1 5.7 0.4 0 0.4 0.4 12 7 5 305 23 0 22 0 -19.6 0 -19.3 -19.7 02/28/2005 09:00:00 8.4 0.9 10.3 6.5 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 9 5 3 305 23 0 23 0 -19.6 0 -19.3 -19.7 02/28/2005 09:10:00 8.7 1.1 11.1 6.5 8.6 1.1 11.1 6.5 0.4 0 0.4 0.4 10 6 10 305 23 0 24 0 -19.7 0 -19.3 -19.9 02/28/2005 09:20:00 9.5 0.9 11.5 6.8 9.4 0.9 11.1 6.8 0.4 0 0.4 0.4 9 5 15 305 24 0 24 0 -19.8 0 -19.5 -20.1 02/28/2005 09:30:00 9.1 0.7 10.3 6.5 8.9 0.8 10.3 6.5 0.4 0 0.4 0.4 12 5 12 305 24 0 24 0 -19.7 0 -19.5 -19.9 02/28/2005 09:40:00 8.7 0.8 10.7 6.5 8.6 0.8 10.3 6.5 0.4 0 0.4 0.4 11 6 16 305 24 0 24 0 -19.7 0 -19.3 -19.9 02/28/2005 09:50:00 8.7 0.7 11.1 6.8 8.7 0.7 10.7 6.8 0.4 0 0.4 0.4 9 5 3 305 24 0 24 0 -19.7 0 -19.5 -19.9 02/28/2005 10:00:00 8.1 1 10.3 5.7 8.1 0.9 10.3 5.7 0.4 0 0.4 0.4 12 5 13 305 24 0 24 0 -19.6 0 -19.3 -19.7 02/28/2005 10:10:00 8.6 1 10.7 6.1 8.3 1 10.7 6.1 0.4 0 0.4 0.4 23 6 20 305 24 0 24 0 -19.5 0 -19.2 -19.5 02/28/2005 10:20:00 9.3 1.1 11.5 6.5 9.1 1.2 11.5 6.1 0.4 0 0.4 0.4 21 6 17 305 24 0 24 0 -19.5 0.1 -19 -19.5 02/28/2005 10:30:00 9.5 1.3 12.2 5.7 9.3 1.2 12.6 6.1 0.4 0 0.4 0.4 16 5 19 305 25 0 25 0 -19.4 0.1 -19 -19.5 02/28/2005 10:40:00 8.4 1 10.7 6.1 8.3 1 10.7 6.1 0.4 0 0.4 0.4 19 6 23 305 25 0 25 0 -19.2 0 -19 -19.5 02/28/2005 10:50:00 8.8 1 11.5 6.5 8.7 1 11.5 6.5 0.4 0 0.4 0.4 17 6 13 305 25 0 25 0 -19.2 0 -19 -19.5 02/28/2005 11:00:00 9.9 1 11.8 7.2 9.9 1.1 11.8 6.8 0.4 0 0.4 0.4 15 4 13 305 25 0 25 0 -19.3 0 -19 -19.5 02/28/2005 11:10:00 9.6 1 11.8 6.5 9.4 1 12.2 6.5 0.4 0 0.4 0.4 20 5 20 305 26 0 26 0 -19.3 0 -19 -19.5 02/28/2005 11:20:00 9.7 0.8 11.8 7.2 9.5 0.8 11.8 7.6 0.4 0 0.4 0.4 23 5 23 305 26 0 26 0 -19.4 0.1 -19 -19.5 02/28/2005 11:30:00 9.4 1 11.1 6.8 9.3 1.1 11.5 6.5 0.4 0 0.4 0.4 24 6 32 305 26 0 26 0 -19.4 0.1 -19 -19.5 02/28/2005 11:40:00 9 1 10.7 6.5 8.9 1 11.5 6.5 0.4 0 0.4 0.4 20 5 21 305 26 0 26 0 -19.4 0.1 -19 -19.5 02/28/2005 11:50:00 9.3 0.9 11.5 6.8 9 1 11.5 6.8 0.4 0 0.4 0.4 28 5 27 305 26 0 27 0 -19.5 0.1 -19 -19.7 02/28/2005 12:00:00 9.3 0.9 11.5 6.8 9 0.9 11.1 6.5 0.4 0 0.4 0.4 27 5 29 305 27 0 26 0 -19.6 0 -19.2 -19.7 02/28/2005 12:10:00 8.6 0.9 11.1 6.5 8.4 1 10.7 6.5 0.4 0 0.4 0.4 32 4 32 305 27 0 27 0 -19.8 0.1 -19.3 -20.1 02/28/2005 12:20:00 7.1 0.8 8.8 4.9 7 0.8 9.1 4.9 0.4 0 0.4 0.4 24 6 34 305 28 0 28 0 -19.7 0 -19.2 -19.9 02/28/2005 12:30:00 7.4 1.3 10.3 5.3 7.4 1.3 9.9 4.9 0.4 0 0.4 0.4 30 8 36 305 30 0 30 0 -19.7 0.1 -19.2 -20.1 02/28/2005 12:40:00 7.6 0.8 9.9 5.3 7.3 0.8 9.5 5.7 0.4 0 0.4 0.4 31 6 35 305 31 0 31 0 -19.7 0.1 -19.3 -19.9 02/28/2005 12:50:00 8.1 0.9 10.3 5.3 8 0.9 9.9 5.3 0.4 0 0.4 0.4 26 7 33 305 32 0 32 0 -19.7 0.1 -19.2 -20.1 02/28/2005 13:00:00 8.2 0.8 9.5 5.3 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 23 6 11 305 31 0 32 0 -19.9 0 -19.3 -20.1 02/28/2005 13:10:00 8 0.8 9.9 6.1 7.7 0.9 9.5 5.7 0.4 0 0.4 0.4 27 7 35 305 31 0 31 0 -19.7 0 -19.3 -19.9 02/28/2005 13:20:00 8.4 0.8 11.1 5.7 8.2 0.8 9.9 5.7 0.4 0 0.4 0.4 34 5 35 305 32 0 32 0 -19.7 0.1 -19.2 -19.9 02/28/2005 13:30:00 8.2 0.8 10.7 6.5 8.2 0.9 10.7 6.5 0.4 0 0.4 0.4 21 6 22 305 32 0 32 0 -19.6 0 -19.2 -19.7 02/28/2005 13:40:00 7.6 0.8 9.5 5.7 7.4 0.9 9.9 5.3 0.4 0 0.4 0.4 18 6 19 305 32 0 32 0 -19.7 0.1 -19.3 -20.1 02/28/2005 13:50:00 8 0.6 9.5 6.5 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 28 6 23 305 32 0 32 0 -19.7 0 -19.2 -19.9 02/28/2005 14:00:00 7.6 0.9 9.5 5.3 7.5 0.9 9.1 5.3 0.4 0 0.4 0.4 30 6 30 305 33 0 32 0 -19.6 0.1 -19.2 -19.7 02/28/2005 14:10:00 7.8 0.7 9.5 6.1 7.6 0.7 9.5 5.7 0.4 0 0.4 0.4 32 5 31 305 34 0 33 0 -19.6 0 -19.2 -19.9 02/28/2005 14:20:00 7.9 0.9 10.3 5.7 7.6 0.8 9.5 5.7 0.4 0 0.4 0.4 30 6 36 305 34 0 35 0 -19.5 0.1 -19 -19.7 02/28/2005 14:30:00 8.2 1 10.7 6.1 8 1 9.9 6.1 0.4 0 0.4 0.4 31 6 32 305 35 0 35 0 -19.5 0 -19 -19.5 02/28/2005 14:40:00 7.6 0.9 9.9 5.3 7.4 0.9 9.9 5.3 0.4 0 0.4 0.4 27 5 29 305 35 0 36 0 -19.4 0.1 -19 -19.5 02/28/2005 14:50:00 7.7 0.8 9.1 6.1 7.6 0.8 9.9 5.3 0.4 0 0.4 0.4 30 5 25 305 35 0 35 0 -19.5 0.1 -19 -19.7 02/28/2005 15:00:00 7.8 0.8 9.5 6.1 7.6 0.8 9.5 5.7 0.4 0 0.4 0.4 26 5 17 305 35 0 35 0 -19.6 0.1 -19 -19.7 02/28/2005 15:10:00 7.5 0.7 9.1 5.7 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 23 7 33 305 34 0 34 0 -19.6 0 -19.2 -19.7 02/28/2005 15:20:00 6.9 1 9.5 4.2 6.9 1 9.9 4.9 0.4 0 0.4 0.4 15 5 13 305 33 0 33 0 -19.4 0.1 -19 -19.7 02/28/2005 15:30:00 8 0.8 9.5 5.7 8 0.8 9.5 5.7 0.4 0 0.4 0.4 17 5 13 305 34 0 34 0 -19.5 0.1 -19 -19.5 02/28/2005 15:40:00 8.8 0.9 11.1 5.7 8.7 0.8 10.7 6.1 0.4 0 0.4 0.4 22 6 29 305 34 0 34 0 -19.3 0 -18.8 -19.5 02/28/2005 15:50:00 8.2 0.7 9.9 5.7 8.1 0.7 9.5 5.7 0.4 0 0.4 0.4 26 5 25 305 35 0 35 0 -19.2 0 -18.8 -19.3 02/28/2005 16:00:00 7.8 0.6 9.1 5.7 7.8 0.7 9.5 6.1 0.4 0 0.4 0.4 14 6 7 305 35 0 35 0 -19.2 0.1 -18.8 -19.5 02/28/2005 16:10:00 8.2 0.8 9.9 5.7 8.2 0.8 9.9 5.7 0.4 0 0.4 0.4 18 8 10 305 35 0 35 0 -19.3 0.1 -18.8 -19.5 02/28/2005 16:20:00 8.9 1.1 11.1 4.9 8.9 1.1 11.1 5.3 0.4 0 0.4 0.4 15 4 18 305 34 0 34 0 -19.4 0 -19 -19.5 02/28/2005 16:30:00 8.8 0.7 10.7 7.2 8.7 0.7 10.7 6.8 0.4 0 0.4 0.4 22 5 27 305 33 0 33 0 -19.4 0.1 -19 -19.5 02/28/2005 16:40:00 9.3 0.8 11.5 7.2 9.1 0.8 11.1 6.8 0.4 0 0.4 0.4 24 6 31 305 33 0 33 0 -19.6 0 -19.2 -19.7 02/28/2005 16:50:00 9 1 11.1 6.1 8.8 1 10.7 6.1 0.4 0 0.4 0.4 22 6 21 305 32 0 32 0 -19.5 0.1 -19.2 -19.5 02/28/2005 17:00:00 9.1 1.2 11.8 6.1 8.9 1.1 11.8 6.5 0.4 0 0.4 0.4 21 6 14 305 32 0 32 0 -19.6 0.1 -19.2 -19.9 02/28/2005 17:10:00 9.7 0.8 11.8 7.2 9.6 0.9 11.8 7.2 0.4 0 0.4 0.4 20 7 14 305 31 0 31 0 -19.7 0.1 -19.2 -19.9 02/28/2005 17:20:00 10.7 0.9 13 8.4 10.6 0.9 12.6 8 0.4 0 0.4 0.4 23 5 17 305 31 0 31 0 -19.7 0.1 -19.3 -19.9 02/28/2005 17:30:00 10.6 1.1 13 8 10.5 1 13 8 0.4 0 0.4 0.4 22 6 29 305 30 0 30 0 -19.7 0.1 -19.2 -19.9 02/28/2005 17:40:00 10.6 1.2 13 7.2 10.6 1.2 13.3 7.2 0.4 0 0.4 0.4 21 5 21 305 31 0 31 0 -19.6 0 -19.2 -19.7 02/28/2005 17:50:00 11.1 1 13 8.4 10.9 1 13 8 0.4 0 0.4 0.4 28 5 33 305 32 0 32 0 -19.6 0 -19.2 -19.7 02/28/2005 18:00:00 11.2 1.2 13.3 8 10.9 1.3 13.3 8 0.4 0 0.4 0.4 27 5 23 305 32 0 32 0 -19.7 0 -19.3 -20.1 02/28/2005 18:10:00 10.6 1.2 14.1 7.6 10.3 1.1 13.3 8 0.4 0 0.4 0.4 28 6 30 305 31 0 31 0 -19.8 0 -19.5 -20.1 02/28/2005 18:20:00 12 1 14.1 8.8 11.7 1 14.1 8.8 0.4 0 0.4 0.4 26 5 25 305 30 0 30 0 -19.9 0 -19.5 -20.1 02/28/2005 18:30:00 12.4 1.1 14.9 9.5 12.2 1.1 15.3 9.5 0.4 0 0.4 0.4 27 5 25 305 29 0 28 0 -19.8 0.1 -19.5 -20.1 02/28/2005 18:40:00 12 1.3 14.5 9.1 11.8 1.3 14.5 8.8 0.4 0 0.4 0.4 27 5 30 305 28 0 28 0 -19.8 0 -19.5 -20.1 02/28/2005 18:50:00 12.1 1 14.5 9.5 11.8 1.1 14.5 9.5 0.4 0 0.4 0.4 29 6 27 305 27 0 28 0 -19.8 0.1 -19.5 -20.1 02/28/2005 19:00:00 11.6 1.3 14.1 7.2 11.3 1.3 14.1 7.2 0.4 0 0.4 0.4 26 5 26 305 26 0 27 0 -19.7 0 -19.3 -19.9 02/28/2005 19:10:00 11 0.9 13 8 10.9 1 13.3 8 0.4 0 0.4 0.4 27 6 30 305 25 0 26 0 -19.6 0 -19.2 -19.7 02/28/2005 19:20:00 10.4 1.3 13.3 6.8 10.2 1.4 13.3 7.2 0.4 0 0.4 0.4 24 6 33 305 25 0 25 0 -19.6 0 -19.2 -19.7 02/28/2005 19:30:00 11.4 1 13.3 8.8 11.1 1 13.7 8 0.4 0 0.4 0.4 20 5 18 305 25 0 25 0 -19.6 0 -19.3 -19.7 02/28/2005 19:40:00 11.3 1 13.3 8.4 11 1.1 13.3 8.4 0.4 0 0.4 0.4 22 5 26 305 25 0 25 0 -19.5 0 -19.2 -19.5 02/28/2005 19:50:00 11.6 1.1 14.5 8.4 11.3 1.2 14.5 8.4 0.4 0 0.4 0.4 21 5 21 305 24 0 25 0 -19.6 0 -19.2 -19.7 02/28/2005 20:00:00 12.1 1 14.1 9.1 11.8 1 14.1 8.4 0.4 0 0.4 0.4 21 6 25 305 24 0 24 0 -19.5 0.1 -19.2 -19.5 02/28/2005 20:10:00 12.2 1 14.5 8.8 12 1.1 14.1 8.4 0.4 0 0.4 0.4 22 5 17 305 24 0 24 0 -19.4 0.1 -19 -19.5 02/28/2005 20:20:00 12 1.3 14.5 8.4 11.7 1.3 14.5 8 0.4 0 0.4 0.4 22 6 19 305 24 0 24 0 -19.3 0 -19 -19.5 02/28/2005 20:30:00 12.2 1 14.5 9.1 11.9 1 14.1 8.8 0.4 0 0.4 0.4 23 5 24 305 25 0 25 0 -19.2 0 -19 -19.5 02/28/2005 20:40:00 11.4 1.4 14.5 8.4 11.2 1.3 14.1 8.4 0.4 0 0.4 0.4 25 5 32 305 25 0 25 0 -19.2 0 -18.8 -19.3 02/28/2005 20:50:00 11.7 0.9 13.7 9.1 11.4 1 13.3 8.8 0.4 0 0.4 0.4 26 5 26 305 25 0 25 0 -19.1 0 -18.8 -19.2 02/28/2005 21:00:00 10.7 1.5 14.5 7.6 10.6 1.5 14.5 7.2 0.4 0 0.4 0.4 25 6 22 305 25 0 25 0 -19 0.1 -18.4 -19 02/28/2005 21:10:00 11.7 1.2 13.7 8.4 11.3 1.2 14.1 8 0.4 0 0.4 0.4 26 5 22 305 25 0 25 0 -18.9 0 -18.4 -19 02/28/2005 21:20:00 11.9 1.1 14.5 8.4 11.6 1.1 14.1 9.1 0.4 0 0.4 0.4 29 5 29 305 25 0 25 0 -18.7 0 -18.4 -19 02/28/2005 21:30:00 11.1 1 13.7 8.8 10.9 1 13.3 8.4 0.4 0 0.4 0.4 31 5 21 305 26 0 26 0 -18.6 0 -18.2 -18.8 02/28/2005 21:40:00 11.4 1.2 14.5 8.4 11.1 1.3 14.5 8 0.4 0 0.4 0.4 25 6 21 305 26 0 26 0 -18.5 0 -18.1 -18.6 02/28/2005 21:50:00 10.5 1.4 13.7 7.6 10.3 1.3 13.3 7.2 0.4 0 0.4 0.4 25 7 25 305 26 0 26 0 -18.5 0.1 -18.1 -18.4 02/28/2005 22:00:00 10.4 1.4 13.7 7.2 10.2 1.5 13.7 6.5 0.4 0 0.4 0.4 22 7 26 305 27 0 27 0 -18.3 0.1 -18.1 -18.4 02/28/2005 22:10:00 12.1 1.3 15.3 9.1 12 1.5 15.3 8.4 0.4 0 0.4 0.4 19 5 14 305 27 0 27 0 -18.2 0 -17.9 -18.4 02/28/2005 22:20:00 11.2 1.2 13.7 8.4 10.9 1.3 14.5 7.6 0.4 0 0.4 0.4 23 6 31 305 27 0 27 0 -18.2 0 -17.7 -18.4 02/28/2005 22:30:00 12.1 1.1 14.9 9.1 11.8 1.2 14.5 8.4 0.4 0 0.4 0.4 23 7 10 305 27 0 28 0 -18.1 0 -17.7 -18.2 02/28/2005 22:40:00 12.7 1.1 15.3 9.1 12.4 1.1 15.3 8.4 0.4 0 0.4 0.4 24 5 31 305 28 0 28 0 -18.2 0.1 -17.7 -18.4 02/28/2005 22:50:00 13.8 1.1 16.4 10.7 13.5 1.3 17.2 10.3 0.4 0 0.4 0.4 23 4 23 305 28 0 28 0 -18.3 0 -17.9 -18.4 02/28/2005 23:00:00 13.6 1.1 16.1 10.7 13.3 1.2 16.4 9.9 0.4 0 0.4 0.4 21 5 16 305 28 0 28 0 -18.1 0.1 -17.7 -18.4 02/28/2005 23:10:00 13.2 1.1 15.6 9.9 12.9 1.1 15.3 9.5 0.4 0 0.4 0.4 23 5 21 305 28 0 27 0 -18.1 0 -17.7 -18.4 02/28/2005 23:20:00 11.6 1.1 14.5 8.8 11.5 1.2 14.5 8.4 0.4 0 0.4 0.4 22 6 32 305 28 0 28 0 -18.1 0 -17.7 -18.2 02/28/2005 23:30:00 11.3 1.2 14.5 7.6 11.1 1.2 14.5 8.4 0.4 0 0.4 0.4 19 7 10 305 28 0 28 0 -18.1 0 -17.7 -18.2 02/28/2005 23:40:00 11.8 1.5 14.9 7.6 11.6 1.5 14.9 7.6 0.4 0 0.4 0.4 17 7 17 305 28 0 28 0 -18.2 0.1 -17.7 -18.4 02/28/2005 23:50:00 10.8 1.2 13.7 8 10.8 1.3 13.3 7.6 0.4 0 0.4 0.4 20 6 11 305 28 0 28 0 -18.2 0 -17.7 -18.4 03/01/2005 00:00:00 10.7 1.3 14.5 8 10.6 1.3 14.1 8 0.4 0 0.4 0.4 11 6 12 305 28 0 28 0 -18.1 0 -17.7 -18.4 03/01/2005 00:10:00 11.7 0.9 13.7 9.1 11.6 1 14.5 9.1 0.4 0 0.4 0.4 12 5 9 305 28 0 28 0 -18.2 0.1 -17.9 -18.4 03/01/2005 00:20:00 11.8 1.2 14.5 9.1 11.8 1.2 14.9 8 0.4 0 0.4 0.4 12 5 10 305 28 0 28 0 -18.5 0 -18.1 -18.6 03/01/2005 00:30:00 11.1 1.3 14.5 7.6 11.1 1.3 14.1 8 0.4 0 0.4 0.4 11 6 16 305 27 0 27 0 -18.6 0 -18.1 -18.8 03/01/2005 00:40:00 11.8 1.3 14.5 7.2 11.7 1.4 14.1 8.4 0.4 0 0.4 0.4 13 6 14 305 27 0 27 0 -18.8 0 -18.4 -19 03/01/2005 00:50:00 11.8 1.2 14.5 9.1 11.7 1.2 14.5 8.4 0.4 0 0.4 0.4 12 6 12 305 27 0 27 0 -18.7 0 -18.4 -19 03/01/2005 01:00:00 12.4 1 15.3 9.5 12.3 1.1 15.3 8.8 0.4 0 0.4 0.4 12 5 13 305 26 0 26 0 -18.8 0.1 -18.4 -19 03/01/2005 01:10:00 11.9 1.1 14.1 8.4 11.8 1.1 14.1 8.8 0.4 0 0.4 0.4 13 4 9 305 26 0 26 0 -18.9 0.1 -18.4 -19 03/01/2005 01:20:00 12.2 1.5 14.9 8 12.2 1.4 15.3 8.8 0.4 0 0.4 0.4 15 5 20 305 26 0 26 0 -19.1 0.2 -18.4 -19.5 03/01/2005 01:30:00 12.2 1.3 14.5 8.4 12 1.4 14.9 8 0.4 0 0.4 0.4 16 5 10 305 25 0 25 0 -19.4 0 -19 -19.5 03/01/2005 01:40:00 10.6 1.5 14.1 7.6 10.5 1.5 14.5 8 0.4 0 0.4 0.4 13 6 11 305 25 0 25 0 -19.3 0 -19 -19.5 03/01/2005 01:50:00 12.1 1 14.9 9.1 12 1.1 14.1 8.8 0.4 0 0.4 0.4 7 5 11 305 24 0 24 0 -19.3 0.1 -19 -19.5 03/01/2005 02:00:00 12.2 1.2 15.6 9.1 12.1 1.2 15.3 8.8 0.4 0 0.4 0.4 10 5 14 305 24 0 24 0 -19.3 0.1 -19 -19.5 03/01/2005 02:10:00 11.5 1.3 14.1 7.6 11.4 1.2 14.1 8.4 0.4 0 0.4 0.4 8 5 5 305 24 0 24 0 -19.5 0.1 -19.2 -19.5 03/01/2005 02:20:00 12.1 1.1 15.3 9.1 12.1 1.1 14.9 9.1 0.4 0 0.4 0.4 10 5 3 305 24 0 24 0 -19.5 0.1 -19 -19.5 03/01/2005 02:30:00 11.8 1.5 14.5 8.4 11.8 1.4 14.5 8 0.4 0 0.4 0.4 10 5 2 305 24 0 24 0 -19.5 0.1 -19 -19.5 03/01/2005 02:40:00 11.9 1.2 14.5 9.1 11.8 1.2 14.1 9.1 0.4 0 0.4 0.4 7 5 3 305 24 0 24 0 -19.6 0 -19.2 -19.7 03/01/2005 02:50:00 11.4 1.7 14.9 7.6 11.3 1.6 14.9 6.8 0.4 0 0.4 0.4 9 5 12 305 23 0 24 0 -19.6 0 -19.3 -19.7 03/01/2005 03:00:00 11.4 1.1 14.5 8.4 11.4 1.1 14.5 8.8 0.4 0 0.4 0.4 10 5 9 305 23 0 24 0 -19.6 0 -19.3 -19.7 03/01/2005 03:10:00 10.5 1 13 8 10.5 1 13 7.6 0.4 0 0.4 0.4 11 5 12 305 23 0 23 0 -19.6 0 -19.2 -19.7 03/01/2005 03:20:00 9.7 1.1 12.6 7.2 9.6 1.1 12.2 7.2 0.4 0 0.4 0.4 9 5 0 305 23 0 23 0 -19.5 0.1 -19.2 -19.5 03/01/2005 03:30:00 9.7 1 12.2 7.2 9.6 1 12.6 6.8 0.4 0 0.4 0.4 10 5 14 305 23 0 23 0 -19.5 0 -19.2 -19.5 03/01/2005 03:40:00 10 1.1 12.6 7.2 9.9 1.1 12.6 7.2 0.4 0 0.4 0.4 9 5 9 305 23 0 23 0 -19.5 0.1 -19.2 -19.5 03/01/2005 03:50:00 9.7 1 11.8 7.6 9.7 1 12.2 7.2 0.4 0 0.4 0.4 10 5 5 305 23 0 23 0 -19.4 0 -19 -19.5 03/01/2005 04:00:00 9.8 1.5 13.7 6.5 9.8 1.5 13.7 6.8 0.4 0 0.4 0.4 16 5 14 305 23 0 24 0 -19.3 0 -19 -19.5 03/01/2005 04:10:00 11.6 0.9 13.7 9.5 11.5 1 13.7 9.1 0.4 0 0.4 0.4 17 4 18 305 24 0 24 0 -19.2 0 -19 -19.3 03/01/2005 04:20:00 11.5 1.1 14.1 8.4 11.4 1.2 14.1 8.8 0.4 0 0.4 0.4 15 5 11 305 24 0 24 0 -19.3 0 -19 -19.5 03/01/2005 04:30:00 11.7 1 13.7 8.8 11.5 1 14.1 8.8 0.4 0 0.4 0.4 15 5 16 305 24 0 24 0 -19.4 0 -19 -19.5 03/01/2005 04:40:00 11.1 1 13.7 8.4 11 1.1 14.1 8.4 0.4 0 0.4 0.4 16 4 17 305 24 0 24 0 -19.6 0 -19.3 -19.7 03/01/2005 04:50:00 9.8 1.5 12.6 6.5 9.8 1.6 13 6.5 0.4 0 0.4 0.4 16 6 23 305 23 0 24 0 -19.6 0 -19.3 -19.7 03/01/2005 05:00:00 8.1 1.4 12.6 5.7 8 1.3 12.6 5.7 0.4 0 0.4 0.4 19 7 12 305 23 0 23 0 -19.8 0.1 -19.5 -20.1 03/01/2005 05:10:00 10.5 1.5 13.3 6.5 10.4 1.5 13.3 6.1 0.4 0 0.4 0.4 16 6 5 305 23 0 23 0 -19.7 0 -19.3 -19.9 03/01/2005 05:20:00 11 1.1 13.3 7.6 10.8 1.1 13.3 8.4 0.4 0 0.4 0.4 18 6 7 305 23 0 23 0 -19.6 0 -19.3 -19.7 03/01/2005 05:30:00 9.6 1.1 13 7.2 9.5 1 13 6.5 0.4 0 0.4 0.4 17 7 23 305 23 0 23 0 -19.6 0 -19.2 -19.7 03/01/2005 05:40:00 10.8 1.1 13.3 8.4 10.8 1.1 13.7 8 0.4 0 0.4 0.4 16 5 13 305 23 0 22 0 -19.4 0.1 -19 -19.5 03/01/2005 05:50:00 13.2 0.9 15.3 10.7 12.9 1 15.6 9.9 0.4 0 0.4 0.4 24 5 24 305 23 0 23 0 -19.4 0.1 -19 -19.5 03/01/2005 06:00:00 11.9 1.5 14.5 8 11.7 1.4 14.5 8 0.4 0 0.4 0.4 20 5 24 305 23 0 23 0 -19.5 0.1 -19.2 -19.5 03/01/2005 06:10:00 12.5 1.7 15.6 8.4 12.2 1.7 15.6 7.6 0.4 0 0.4 0.4 16 5 8 305 23 0 22 0 -19.6 0 -19.2 -19.7 03/01/2005 06:20:00 12.5 1.2 15.3 9.1 12.3 1.3 15.3 8.8 0.4 0 0.4 0.4 17 5 14 305 23 0 23 0 -19.6 0 -19.3 -19.7 03/01/2005 06:30:00 9.9 1.2 13.3 6.8 9.8 1.2 13 6.8 0.4 0 0.4 0.4 21 8 8 305 23 0 23 0 -19.7 0.1 -19.3 -20.1 03/01/2005 06:40:00 9.2 0.9 11.5 6.5 8.8 0.9 11.1 6.8 0.4 0 0.4 0.4 30 6 30 305 23 0 22 0 -20.1 0 -19.7 -20.1 03/01/2005 06:50:00 9.1 1.5 13 6.5 9 1.5 12.6 6.1 0.4 0 0.4 0.4 17 7 16 305 22 0 22 0 -20 0.1 -19.5 -20.1 03/01/2005 07:00:00 11.3 1.5 14.9 7.6 11.3 1.5 14.9 7.2 0.4 0 0.4 0.4 15 5 17 305 22 0 22 0 -19.7 0 -19.5 -19.9 03/01/2005 07:10:00 12.1 1.5 15.3 7.2 12 1.5 15.3 8 0.4 0 0.4 0.4 15 6 10 305 22 0 22 0 -19.6 0 -19.3 -19.7 03/01/2005 07:20:00 12 1.3 15.3 8.8 12 1.3 15.3 8.8 0.4 0 0.4 0.4 12 6 9 305 23 0 23 0 -19.6 0 -19.3 -19.7 03/01/2005 07:30:00 11.8 1.6 14.9 7.6 11.6 1.6 14.9 7.6 0.4 0 0.4 0.4 16 6 16 305 23 0 23 0 -19.6 0 -19.2 -19.7 03/01/2005 07:40:00 13.3 1.2 15.6 9.9 13 1.2 15.6 9.9 0.4 0 0.4 0.4 18 5 16 305 23 0 23 0 -19.9 0.2 -19.5 -20.1 03/01/2005 07:50:00 12.9 1.5 16.1 9.1 12.9 1.5 16.1 8.4 0.4 0 0.4 0.4 16 5 16 305 22 0 23 0 -20 0.1 -19.7 -20.1 03/01/2005 08:00:00 11.6 1.7 14.9 8.4 11.4 1.6 14.9 8 0.4 0 0.4 0.4 18 6 12 305 22 0 22 0 -20 0 -19.5 -20.1 03/01/2005 08:10:00 12.4 1.3 15.6 9.1 12.1 1.5 16.1 8.4 0.4 0 0.4 0.4 24 6 29 305 22 0 22 0 -20 0 -19.7 -20.1 03/01/2005 08:20:00 11.4 1.2 13.3 8.4 11.2 1.2 13.7 8 0.4 0 0.4 0.4 29 6 27 305 22 0 22 0 -20.2 0 -19.9 -20.2 03/01/2005 08:30:00 12.4 1.5 15.6 8.8 12.2 1.6 15.3 8.4 0.4 0 0.4 0.4 26 6 27 305 22 0 22 0 -20.4 0.1 -20.1 -20.6 03/01/2005 08:40:00 12.6 1.2 15.6 9.5 12.4 1.2 15.3 9.1 0.4 0 0.4 0.4 25 6 32 305 21 0 21 0 -20.5 0.1 -20.1 -20.8 03/01/2005 08:50:00 12.7 1.6 15.6 8.8 12.5 1.7 15.6 8.8 0.4 0 0.4 0.4 21 6 15 305 21 0 21 0 -20.3 0 -20.1 -20.6 03/01/2005 09:00:00 10.8 1.5 14.9 7.6 10.7 1.5 14.5 7.2 0.4 0 0.4 0.4 22 7 24 305 21 0 21 0 -20.4 0 -20.1 -20.6 03/01/2005 09:10:00 12.6 1.7 16.8 8.4 12.4 1.7 16.1 8.4 0.4 0 0.4 0.4 16 6 18 305 21 0 21 0 -20.3 0 -20.1 -20.4 03/01/2005 09:20:00 12.9 1.7 16.8 9.1 12.8 1.7 16.8 9.1 0.4 0 0.4 0.4 17 5 18 305 21 0 21 0 -20.5 0.1 -20.1 -20.8 03/01/2005 09:30:00 12.9 1.5 16.4 8.8 12.8 1.5 17.2 8.8 0.4 0 0.4 0.4 21 8 17 305 21 0 21 0 -20.6 0.1 -20.2 -20.8 03/01/2005 09:40:00 11.7 1.7 16.1 8 11.5 1.7 16.1 7.6 0.4 0 0.4 0.4 20 7 17 305 21 0 21 0 -20.6 0 -20.2 -20.8 03/01/2005 09:50:00 12.6 1.3 16.1 8.8 12.5 1.4 16.4 8.4 0.4 0 0.4 0.4 19 7 17 305 21 0 21 0 -20.7 0 -20.4 -20.8 03/01/2005 10:00:00 12 1.4 15.3 9.1 11.9 1.5 15.3 8.8 0.4 0 0.4 0.4 23 7 20 305 20 0 21 0 -20.9 0.1 -20.6 -21.1 03/01/2005 10:10:00 13.7 1.7 17.6 9.1 13.5 1.7 18.3 9.1 0.4 0 0.4 0.4 17 6 19 305 20 0 20 0 -20.7 0 -20.6 -20.8 03/01/2005 10:20:00 14 2 17.2 8.4 13.8 2 17.6 8 0.4 0 0.4 0.4 11 5 10 305 20 0 20 0 -20.7 0 -20.6 -20.8 03/01/2005 10:30:00 13.6 1.7 17.6 9.5 13.6 1.7 17.6 9.9 0.4 0 0.4 0.4 14 7 23 305 21 0 20 0 -20.7 0 -20.4 -20.8 03/01/2005 10:40:00 14.4 1.4 17.6 10.7 14.1 1.5 17.9 10.7 0.4 0 0.4 0.4 16 6 16 305 21 0 21 0 -20.7 0 -20.6 -21 03/01/2005 10:50:00 14.1 1.7 17.6 9.1 14 1.7 17.6 9.5 0.4 0 0.4 0.4 16 5 15 305 21 0 21 0 -20.8 0 -20.6 -21 03/01/2005 11:00:00 13.6 1.5 16.8 9.5 13.5 1.5 17.2 9.5 0.4 0 0.4 0.4 11 6 15 305 21 0 20 0 -20.7 0 -20.4 -21 03/01/2005 11:10:00 13.5 1.5 18.3 8.8 13.4 1.4 17.6 8.8 0.4 0 0.4 0.4 15 6 14 305 22 0 22 0 -20.5 0.1 -20.1 -20.8 03/01/2005 11:20:00 14 1.2 17.6 11.1 13.8 1.2 16.8 11.1 0.4 0 0.4 0.4 11 4 12 305 22 0 22 0 -20.5 0.1 -20.1 -20.8 03/01/2005 11:30:00 14.2 1.6 17.9 9.9 14 1.5 17.9 10.3 0.4 0 0.4 0.4 12 5 18 305 23 0 22 0 -20.7 0.1 -20.1 -21 03/01/2005 11:40:00 13.7 1.4 17.2 9.5 13.6 1.5 17.6 10.3 0.4 0 0.4 0.4 12 6 12 305 23 0 22 0 -20.6 0 -20.2 -20.8 03/01/2005 11:50:00 13 1.5 17.2 9.5 12.8 1.5 17.2 9.1 0.4 0 0.4 0.4 11 6 9 305 23 0 23 0 -20.4 0.1 -20.1 -20.8 03/01/2005 12:00:00 12.7 1.7 16.8 8.4 12.7 1.7 17.2 8.4 0.4 0 0.4 0.4 12 6 21 305 24 0 24 0 -20.2 0 -19.9 -20.4 03/01/2005 12:10:00 14.3 1.7 18.3 9.9 14.2 1.7 18.7 10.3 0.4 0 0.4 0.4 12 5 12 305 24 0 24 0 -20.2 0 -19.9 -20.2 03/01/2005 12:20:00 16 1.7 19.9 11.5 15.8 1.7 19.9 10.7 0.4 0 0.4 0.4 12 5 14 305 24 0 24 0 -20.2 0 -19.9 -20.2 03/01/2005 12:30:00 14.7 1.9 18.3 9.9 14.5 1.9 17.9 9.9 0.4 0 0.4 0.4 10 5 19 305 24 0 24 0 -20.2 0 -19.9 -20.2 03/01/2005 12:40:00 14.4 1.6 17.9 10.7 14.1 1.5 17.9 10.3 0.4 0 0.4 0.4 11 5 18 305 24 0 24 0 -20.1 0.1 -19.5 -20.4 03/01/2005 12:50:00 12.9 1.9 18.3 9.1 12.9 1.9 17.2 8.8 0.4 0 0.4 0.4 14 6 16 305 24 0 24 0 -19.5 0.2 -19 -20.1 03/01/2005 13:00:00 14.8 1.7 19.5 9.9 14.7 1.7 19.9 10.3 0.4 0 0.4 0.4 16 7 25 305 26 0 25 0 -19.3 0.1 -19 -19.5 03/01/2005 13:10:00 15.3 1.2 17.6 11.5 15.1 1.2 17.9 11.1 0.4 0 0.4 0.4 9 5 5 305 27 0 27 0 -19.5 0.1 -19 -19.7 03/01/2005 13:20:00 14.1 1.4 17.9 10.3 14 1.5 17.9 9.9 0.4 0 0.4 0.4 11 5 10 305 26 0 26 0 -19.6 0.1 -19.2 -19.5 03/01/2005 13:30:00 14.9 1.5 18.7 11.1 14.7 1.3 17.9 11.8 0.4 0 0.4 0.4 9 5 24 305 26 0 26 0 -19.5 0.1 -19 -19.5 03/01/2005 13:40:00 13.7 1.5 17.6 9.9 13.5 1.4 17.2 9.5 0.4 0 0.4 0.4 12 6 14 305 26 0 26 0 -19.2 0.1 -18.8 -19.5 03/01/2005 13:50:00 14.2 1.2 16.8 11.5 14.1 1.2 17.2 11.1 0.4 0 0.4 0.4 10 6 12 305 27 0 27 0 -19.3 0.1 -18.8 -19.5 03/01/2005 14:00:00 13.7 1.6 17.9 9.5 13.7 1.6 17.6 9.1 0.4 0 0.4 0.4 13 5 17 305 27 0 27 0 -19.3 0.1 -19 -19.5 03/01/2005 14:10:00 14.9 1.5 18.3 10.7 14.7 1.4 17.9 11.1 0.4 0 0.4 0.4 14 6 15 305 27 0 27 0 -19.2 0.1 -18.8 -19.5 03/01/2005 14:20:00 15 1.7 18.3 9.9 14.6 1.8 17.9 10.7 0.4 0 0.4 0.4 12 6 27 305 27 0 27 0 -19.1 0.1 -18.6 -19.3 03/01/2005 14:30:00 13.8 1.4 17.6 10.3 13.7 1.5 17.9 9.9 0.4 0 0.4 0.4 14 5 18 305 28 0 27 0 -19.1 0 -18.6 -19.3 03/01/2005 14:40:00 12.8 1.5 16.4 9.5 12.9 1.4 16.1 9.9 0.4 0 0.4 0.4 15 5 16 305 28 0 28 0 -19 0.1 -18.4 -19.2 03/01/2005 14:50:00 14.2 1.4 17.9 9.9 14 1.4 17.9 9.9 0.4 0 0.4 0.4 15 6 9 305 29 0 29 0 -18.8 0.1 -18.4 -19 03/01/2005 15:00:00 15.4 1.7 19.5 11.1 15.1 1.7 19.1 10.3 0.4 0 0.4 0.4 13 5 22 305 29 0 29 0 -18.9 0.1 -18.4 -19 03/01/2005 15:10:00 14.7 1.9 19.5 9.9 14.5 1.8 19.1 9.9 0.4 0 0.4 0.4 13 5 8 305 29 0 29 0 -18.7 0.2 -18.1 -19 03/01/2005 15:20:00 15.7 1.9 21 11.8 15.5 1.9 21.4 11.5 0.4 0 0.4 0.4 15 6 13 305 29 0 29 0 -18.8 0.1 -18.4 -19 03/01/2005 15:30:00 16.1 1.7 20.6 11.8 15.8 1.7 21 12.2 0.4 0 0.4 0.4 17 6 22 305 29 0 29 0 -19 0.1 -18.4 -19 03/01/2005 15:40:00 15.3 2.3 19.9 9.5 15 2.2 19.5 9.5 0.4 0 0.4 0.4 13 5 11 305 30 0 30 0 -18.8 0.1 -18.4 -19 03/01/2005 15:50:00 15 2 20.2 9.9 14.9 2 20.2 10.3 0.4 0 0.4 0.4 18 6 19 305 30 0 30 0 -18.7 0.1 -18.2 -19 03/01/2005 16:00:00 15.4 1.6 19.1 11.1 15.1 1.6 19.1 11.1 0.4 0 0.4 0.4 19 7 10 305 30 0 29 0 -18.7 0.1 -18.2 -19 03/01/2005 16:10:00 16.1 1.5 20.2 13 15.7 1.5 19.9 12.2 0.4 0 0.4 0.4 21 5 21 305 30 0 30 0 -18.7 0.1 -18.2 -19 03/01/2005 16:20:00 15.1 1.7 19.1 11.1 14.8 1.7 19.1 10.3 0.4 0 0.4 0.4 19 6 18 305 30 0 29 0 -18.5 0.2 -17.7 -18.8 03/01/2005 16:30:00 14.9 1.7 19.9 11.5 14.7 1.7 21 10.7 0.4 0 0.4 0.4 21 7 25 305 31 0 31 0 -18.2 0.2 -17.7 -18.4 03/01/2005 16:40:00 15.3 1.7 19.1 11.1 15 1.7 19.1 9.9 0.4 0 0.4 0.4 26 6 25 305 31 0 31 0 -18.5 0.1 -18.1 -18.6 03/01/2005 16:50:00 15.6 2 19.9 10.3 15.3 2 19.5 10.3 0.4 0 0.4 0.4 20 6 29 305 31 0 31 0 -18.3 0.1 -17.9 -18.4 03/01/2005 17:00:00 14.7 2 20.6 8 14.5 2 19.5 8.4 0.4 0 0.4 0.4 20 6 15 305 30 0 31 0 -18.3 0.1 -17.9 -18.4 03/01/2005 17:10:00 14.8 1.9 19.9 10.3 14.4 1.9 19.9 9.5 0.4 0 0.4 0.4 20 6 14 305 31 0 30 0 -18.3 0.1 -17.9 -18.4 03/01/2005 17:20:00 14.9 1.5 17.9 11.1 14.7 1.5 17.6 10.7 0.4 0 0.4 0.4 24 6 37 305 32 0 32 0 -18.2 0.2 -17.5 -18.6 03/01/2005 17:30:00 16.4 1.7 20.2 11.8 16.1 1.7 19.9 12.2 0.4 0 0.4 0.4 19 7 14 305 32 0 32 0 -18.5 0.1 -18.1 -18.6 03/01/2005 17:40:00 16.2 2.2 21.8 11.1 15.9 2.1 21.8 10.7 0.4 0 0.4 0.4 21 5 21 305 32 0 31 0 -18.5 0.1 -18.1 -18.6 03/01/2005 17:50:00 16 1.6 19.9 11.8 15.8 1.5 19.5 11.8 0.4 0 0.4 0.4 23 6 26 305 31 0 31 0 -18.3 0.1 -17.9 -18.4 03/01/2005 18:00:00 14.8 1.7 19.1 11.1 14.7 1.7 19.1 11.1 0.4 0 0.4 0.4 18 6 16 305 31 0 31 0 -18.2 0.1 -17.7 -18.4 03/01/2005 18:10:00 16 2.3 20.2 9.5 15.8 2.4 20.6 9.9 0.4 0 0.4 0.4 15 6 22 305 30 0 31 0 -18.4 0.1 -17.9 -18.6 03/01/2005 18:20:00 15.5 1.7 19.9 11.5 15.2 1.7 18.7 10.7 0.4 0 0.4 0.4 20 6 32 305 29 0 29 0 -18.6 0.1 -18.1 -18.8 03/01/2005 18:30:00 16.3 2.5 21 9.5 16.1 2.5 21 10.3 0.4 0 0.4 0.4 16 6 13 305 29 0 29 0 -18.5 0.1 -18.1 -18.6 03/01/2005 18:40:00 15.9 2.4 21.4 10.7 15.7 2.3 21.4 10.7 0.4 0 0.4 0.4 14 6 13 305 29 0 29 0 -18.4 0.1 -18.1 -18.4 03/01/2005 18:50:00 17.3 1.8 21.8 13 17.1 1.8 21.8 13 0.4 0 0.4 0.4 14 5 16 305 29 0 29 0 -18.7 0.1 -18.1 -19 03/01/2005 19:00:00 15.9 2 20.2 11.5 15.8 1.9 20.2 11.1 0.4 0 0.4 0.4 14 6 17 305 28 0 28 0 -18.8 0 -18.4 -19 03/01/2005 19:10:00 17.2 1.5 20.6 12.6 17.1 1.4 20.2 13 0.4 0 0.4 0.4 18 5 16 305 26 0 26 0 -19 0.1 -18.4 -19.2 03/01/2005 19:20:00 14.6 1.8 18.3 9.5 14.4 1.7 18.7 10.3 0.4 0 0.4 0.4 18 6 12 305 25 0 26 0 -19.2 0.1 -18.8 -19.3 03/01/2005 19:30:00 14.6 1.8 18.7 10.3 14.5 1.8 18.7 10.3 0.4 0 0.4 0.4 15 5 12 305 25 0 25 0 -19.1 0.1 -18.8 -19.3 03/01/2005 19:40:00 14.5 1.5 17.9 10.7 14.2 1.6 17.9 10.3 0.4 0 0.4 0.4 18 6 22 305 24 0 24 0 -19.2 0.1 -18.8 -19.5 03/01/2005 19:50:00 14.8 1.3 17.6 10.3 14.5 1.3 18.3 10.7 0.4 0 0.4 0.4 17 5 14 305 24 0 24 0 -19.1 0 -18.8 -19.2 03/01/2005 20:00:00 17.3 2.1 21 10.3 16.9 2.1 21 10.7 0.4 0 0.4 0.4 17 6 23 305 24 0 24 0 -19.1 0 -18.8 -19.2 03/01/2005 20:10:00 15.9 1.8 20.6 12.2 15.7 1.7 20.2 11.8 0.4 0 0.4 0.4 19 5 22 305 24 0 24 0 -19.1 0 -18.6 -19.2 03/01/2005 20:20:00 16.4 1.9 20.6 12.2 16.2 1.9 20.6 12.2 0.4 0 0.4 0.4 16 5 20 305 24 0 24 0 -19 0 -18.6 -19 03/01/2005 20:30:00 16.6 1.9 21 12.2 16.4 2 20.6 11.5 0.4 0 0.4 0.4 15 5 12 305 24 0 24 0 -18.8 0 -18.4 -19 03/01/2005 20:40:00 16.8 2 21 11.8 16.7 2 21 11.8 0.4 0 0.4 0.4 15 6 19 305 25 0 25 0 -18.7 0 -18.2 -19 03/01/2005 20:50:00 17.2 1.7 20.6 13 16.9 1.7 20.2 12.6 0.4 0 0.4 0.4 17 6 19 305 25 0 25 0 -18.8 0 -18.4 -19 03/01/2005 21:00:00 16.9 1.7 20.6 12.6 16.6 1.7 21 12.6 0.4 0 0.4 0.4 17 5 15 305 25 0 25 0 -18.8 0 -18.4 -19 03/01/2005 21:10:00 15.7 1.9 19.9 11.1 15.6 1.8 19.9 10.7 0.4 0 0.4 0.4 16 5 12 305 25 0 25 0 -18.7 0.1 -18.2 -19 03/01/2005 21:20:00 18.4 2.1 22.9 13.3 18.1 2.2 23.3 13 0.4 0 0.4 0.4 16 5 18 305 25 0 25 0 -18.7 0 -18.4 -19 03/01/2005 21:30:00 16.5 2.2 22.1 11.5 16.1 2.1 21.8 11.5 0.4 0 0.4 0.4 17 6 17 305 25 0 25 0 -18.8 0 -18.4 -19 03/01/2005 21:40:00 15.4 2 21 10.7 15.2 1.9 20.6 9.9 0.4 0 0.4 0.4 21 6 14 305 25 0 25 0 -18.8 0 -18.4 -19 03/01/2005 21:50:00 17.3 1.9 22.9 13 16.9 1.8 22.9 12.2 0.4 0 0.4 0.4 25 5 22 305 25 0 25 0 -18.9 0.1 -18.4 -19 03/01/2005 22:00:00 17.4 1.8 21 13 17.1 1.7 20.6 13.3 0.4 0 0.4 0.4 19 6 25 305 25 0 25 0 -18.9 0.1 -18.4 -19 03/01/2005 22:10:00 16.1 1.5 19.5 11.1 15.9 1.5 19.5 12.2 0.4 0 0.4 0.4 18 6 11 305 25 0 25 0 -19 0.1 -18.4 -19 03/01/2005 22:20:00 16.7 2.3 21.8 11.5 16.5 2.3 22.1 11.5 0.4 0 0.4 0.4 16 5 18 305 25 0 25 0 -19.1 0 -18.6 -19.3 03/01/2005 22:30:00 16.5 1.7 21.4 12.2 16.2 1.7 20.2 11.8 0.4 0 0.4 0.4 17 6 18 305 24 0 24 0 -19.2 0 -19 -19.3 03/01/2005 22:40:00 15.1 2 21.4 10.7 14.9 2 20.6 10.3 0.4 0 0.4 0.4 18 6 14 305 24 0 24 0 -19.2 0 -19 -19.5 03/01/2005 22:50:00 15.4 2.3 20.2 9.9 15.3 2.3 21 9.9 0.4 0 0.4 0.4 22 6 21 305 24 0 24 0 -19.4 0.1 -19 -19.5 03/01/2005 23:00:00 14.7 1.8 20.2 10.7 14.5 1.7 19.5 10.7 0.4 0 0.4 0.4 22 6 27 305 24 0 24 0 -19.2 0.1 -19 -19.5 03/01/2005 23:10:00 13.6 1.4 18.3 8.8 13.4 1.3 18.7 9.1 0.4 0 0.4 0.4 22 6 21 305 24 0 24 0 -19.2 0.1 -18.8 -19.3 03/01/2005 23:20:00 14.4 1.9 19.1 10.7 14.1 1.9 19.5 9.9 0.4 0 0.4 0.4 14 6 13 305 24 0 24 0 -19.1 0 -18.6 -19.2 03/01/2005 23:30:00 14 2.3 19.9 9.1 13.8 2.2 19.1 8.4 0.4 0 0.4 0.4 11 6 13 305 24 0 24 0 -19.2 0.1 -18.8 -19.5 03/01/2005 23:40:00 14.3 1.9 18.7 10.3 14 1.8 19.1 9.5 0.4 0 0.4 0.4 12 6 9 305 24 0 24 0 -19.3 0 -19 -19.5 03/01/2005 23:50:00 15.2 1.9 19.9 10.3 15.1 1.9 19.5 10.7 0.4 0 0.4 0.4 14 5 12 305 24 0 24 0 -19.4 0.1 -19 -19.5 03/02/2005 00:00:00 14.3 1.8 18.3 9.1 14.1 1.8 18.3 9.1 0.4 0 0.4 0.4 10 6 12 305 24 0 24 0 -19.5 0.1 -19 -19.5 03/02/2005 00:10:00 15.9 1.5 19.5 11.5 15.6 1.5 19.1 11.5 0.4 0 0.4 0.4 12 5 10 305 23 0 24 0 -19.6 0 -19.3 -19.9 03/02/2005 00:20:00 12.6 1.7 17.2 9.1 12.5 1.7 17.2 9.5 0.4 0 0.4 0.4 12 5 12 305 23 0 23 0 -19.7 0.1 -19.5 -19.9 03/02/2005 00:30:00 12.1 1.3 16.1 8.4 12 1.3 16.4 8.4 0.4 0 0.4 0.4 13 5 17 305 23 0 23 0 -19.8 0 -19.5 -19.9 03/02/2005 00:40:00 13 1.8 17.6 8.8 13 1.8 17.6 8.4 0.4 0 0.4 0.4 12 8 15 305 22 0 22 0 -19.8 0.1 -19.5 -20.1 03/02/2005 00:50:00 10.9 1.2 13.7 8 11 1.2 14.5 8 0.4 0 0.4 0.4 352 6 351 305 22 0 22 0 -20.5 0.2 -19.7 -20.8 03/02/2005 01:00:00 10.2 1.1 13.3 7.2 10.3 1.1 13.7 7.2 0.4 0 0.4 0.4 358 6 9 305 21 0 21 0 -20.6 0.1 -20.1 -20.8 03/02/2005 01:10:00 11.3 1.4 14.5 8 11.3 1.4 14.5 8 0.4 0 0.4 0.4 1 5 3 305 21 0 21 0 -20.5 0.2 -20.1 -20.8 03/02/2005 01:20:00 12 1.1 14.5 8.8 11.9 1.1 14.5 9.1 0.4 0 0.4 0.4 4 6 356 305 21 0 21 0 -20.8 0.1 -20.6 -21 03/02/2005 01:30:00 11.6 1.9 16.1 7.2 11.6 1.9 15.6 8 0.4 0 0.4 0.4 16 7 21 305 21 0 21 0 -20.5 0.3 -19.9 -20.8 03/02/2005 01:40:00 10.6 1.5 14.9 7.6 10.7 1.5 14.9 8 0.4 0 0.4 0.4 6 7 13 305 21 0 21 0 -20.3 0.2 -19.7 -20.8 03/02/2005 01:50:00 10.4 1 13.3 8.4 10.4 1.1 13.3 8 0.4 0 0.4 0.4 1 5 10 305 21 0 21 0 -20.6 0 -20.4 -20.8 03/02/2005 02:00:00 10.4 0.9 12.6 7.6 10.4 1 12.6 8 0.4 0 0.4 0.4 355 4 348 305 21 0 21 0 -20.8 0.1 -20.6 -21.1 03/02/2005 02:10:00 10 1 12.2 6.8 10.1 1.1 13 7.2 0.4 0 0.4 0.4 357 5 348 305 20 0 21 0 -20.8 0 -20.6 -21.1 03/02/2005 02:20:00 11.2 2.3 17.9 7.2 11.2 2.2 17.6 8 0.4 0 0.4 0.4 5 7 9 305 21 0 21 0 -20.3 0.3 -19.5 -20.8 03/02/2005 02:30:00 14.1 1.7 17.9 9.5 13.9 1.7 18.3 9.9 0.4 0 0.4 0.4 13 6 18 305 21 0 21 0 -19.8 0 -19.5 -19.9 03/02/2005 02:40:00 13.6 1.7 18.3 9.5 13.5 1.7 17.9 9.1 0.4 0 0.4 0.4 17 7 33 305 22 0 22 0 -19.7 0 -19.3 -19.9 03/02/2005 02:50:00 12.9 1.6 17.2 9.1 12.8 1.7 17.2 9.5 0.4 0 0.4 0.4 15 7 10 305 22 0 22 0 -19.7 0 -19.3 -19.9 03/02/2005 03:00:00 13.3 1.4 16.4 9.9 13.1 1.4 16.8 9.5 0.4 0 0.4 0.4 22 6 25 305 22 0 22 0 -19.8 0 -19.5 -20.1 03/02/2005 03:10:00 14.4 1.1 17.6 11.8 14.3 1.2 17.6 11.5 0.4 0 0.4 0.4 22 5 21 305 22 0 22 0 -19.7 0 -19.5 -19.9 03/02/2005 03:20:00 12.2 1.9 17.2 8.4 12.3 1.8 17.2 8.8 0.4 0 0.4 0.4 15 7 22 305 22 0 22 0 -19.7 0 -19.3 -19.9 03/02/2005 03:30:00 11.9 1.5 15.3 8.4 11.7 1.4 15.3 8.8 0.4 0 0.4 0.4 10 5 7 305 22 0 22 0 -19.8 0 -19.5 -19.9 03/02/2005 03:40:00 12.1 1.4 16.8 8.8 12.1 1.4 16.4 8.4 0.4 0 0.4 0.4 8 5 10 305 22 0 22 0 -20 0.1 -19.5 -20.1 03/02/2005 03:50:00 13.2 1.5 17.2 9.5 13.1 1.4 17.2 9.9 0.4 0 0.4 0.4 13 6 16 305 22 0 22 0 -19.9 0.1 -19.5 -20.1 03/02/2005 04:00:00 14.6 1.6 18.3 10.3 14.3 1.7 18.7 10.3 0.4 0 0.4 0.4 19 6 21 305 22 0 22 0 -19.7 0 -19.3 -19.9 03/02/2005 04:10:00 14.8 1.5 18.3 11.1 14.5 1.6 18.3 10.7 0.4 0 0.4 0.4 22 5 20 305 22 0 22 0 -19.8 0 -19.5 -20.1 03/02/2005 04:20:00 14.5 2.1 18.3 9.1 14.3 2.1 18.3 9.5 0.4 0 0.4 0.4 19 6 16 305 22 0 22 0 -19.9 0.1 -19.5 -20.1 03/02/2005 04:30:00 12.5 1.5 15.6 8.4 12.4 1.5 15.6 8.4 0.4 0 0.4 0.4 22 6 18 305 22 0 22 0 -20 0.1 -19.5 -20.1 03/02/2005 04:40:00 13.2 1.5 17.2 9.9 13 1.4 17.2 9.5 0.4 0 0.4 0.4 21 6 22 305 22 0 22 0 -19.9 0.1 -19.5 -20.1 03/02/2005 04:50:00 14.2 1.5 18.3 10.7 14 1.5 18.3 9.9 0.4 0 0.4 0.4 18 5 19 305 22 0 22 0 -20.1 0.1 -19.7 -20.1 03/02/2005 05:00:00 13.4 1.9 18.7 9.1 13.2 1.9 18.7 8.8 0.4 0 0.4 0.4 19 7 17 305 22 0 22 0 -20.2 0 -19.7 -20.2 03/02/2005 05:10:00 14 1.7 17.9 9.5 13.8 1.7 18.3 9.9 0.4 0 0.4 0.4 13 6 12 305 22 0 22 0 -20.2 0 -19.9 -20.4 03/02/2005 05:20:00 14.6 2.3 19.5 9.5 14.5 2.3 18.7 9.5 0.4 0 0.4 0.4 15 7 16 305 21 0 21 0 -20.3 0.1 -19.9 -20.6 03/02/2005 05:30:00 15 1.7 19.5 10.7 14.8 1.7 19.5 9.9 0.4 0 0.4 0.4 17 6 14 305 21 0 21 0 -20.6 0.1 -20.1 -20.8 03/02/2005 05:40:00 15.1 1.8 19.1 10.7 14.9 1.8 19.5 10.7 0.4 0 0.4 0.4 21 6 15 305 21 0 20 0 -20.8 0 -20.4 -21 03/02/2005 05:50:00 15.5 2 20.6 10.7 15.2 1.9 21 10.7 0.4 0 0.4 0.4 20 5 27 305 20 0 20 0 -20.9 0 -20.8 -21.1 03/02/2005 06:00:00 12.1 1.7 17.2 8.8 11.8 1.7 16.4 8 0.4 0 0.4 0.4 14 9 19 305 20 0 20 0 -21 0 -20.8 -21.3 03/02/2005 06:10:00 12.7 1.3 16.1 9.5 12.5 1.3 16.1 9.5 0.4 0 0.4 0.4 22 8 31 305 20 0 20 0 -21.4 0 -21.3 -21.7 03/02/2005 06:20:00 12.3 1.4 16.1 8.4 12.1 1.5 15.6 8.4 0.4 0 0.4 0.4 13 8 12 305 19 0 19 0 -21.6 0 -21.3 -21.8 03/02/2005 06:30:00 11.2 1.5 14.5 7.6 11.1 1.3 15.3 7.6 0.4 0 0.4 0.4 3 8 357 305 19 0 19 0 -21.9 0.1 -21.5 -22 03/02/2005 06:40:00 12.8 1.5 16.8 8.8 12.6 1.3 17.2 9.5 0.4 0 0.4 0.4 9 6 12 305 18 0 18 0 -22 0.2 -21.7 -22.4 03/02/2005 06:50:00 14 2.2 18.7 7.6 13.7 2.2 17.9 7.6 0.4 0 0.4 0.4 19 6 21 305 18 0 18 0 -22.3 0 -22 -22.5 03/02/2005 07:00:00 11.5 1.5 16.1 7.6 11.2 1.5 16.4 8 0.4 0 0.4 0.4 14 7 8 305 17 0 18 0 -22.5 0.1 -22.4 -22.7 03/02/2005 07:10:00 14 1.6 18.3 9.9 13.7 1.6 17.2 9.9 0.4 0 0.4 0.4 22 5 35 305 17 0 17 0 -22.6 0 -22.2 -22.9 03/02/2005 07:20:00 14.1 1.2 17.6 10.7 13.7 1.3 17.2 10.3 0.4 0 0.4 0.4 25 6 21 305 17 0 17 0 -22.8 0 -22.5 -22.9 03/02/2005 07:30:00 11.8 2 16.8 6.8 11.7 1.8 16.8 7.2 0.4 0 0.4 0.4 11 9 23 305 16 0 16 0 -22.9 0 -22.7 -23 03/02/2005 07:40:00 12.5 1.8 16.1 8.4 12.4 1.8 16.1 8.8 0.4 0 0.4 0.4 13 6 9 305 16 0 16 0 -22.9 0 -22.7 -23.2 03/02/2005 07:50:00 14.1 1.4 17.2 10.3 13.9 1.5 17.6 9.9 0.4 0 0.4 0.4 21 6 23 305 16 0 15 0 -23.1 0 -22.9 -23.2 03/02/2005 08:00:00 15.6 1.7 18.7 10.7 15.1 1.7 18.7 10.3 0.4 0 0.4 0.4 24 5 22 305 15 0 15 0 -23.2 0 -22.9 -23.2 03/02/2005 08:10:00 12.2 1.6 16.8 8 12 1.6 16.4 8 0.4 0 0.4 0.4 15 6 23 305 15 0 15 0 -23.2 0 -22.9 -23.2 03/02/2005 08:20:00 11.8 1.7 17.2 7.6 11.6 1.8 17.2 7.6 0.4 0 0.4 0.4 16 6 12 305 15 0 15 0 -23.2 0.1 -23 -23.4 03/02/2005 08:30:00 13.9 1.4 18.3 9.9 13.4 1.5 17.9 9.9 0.4 0 0.4 0.4 20 5 15 305 15 0 15 0 -23.4 0 -23.2 -23.4 03/02/2005 08:40:00 14.8 1.7 17.9 10.3 14.5 1.7 17.9 10.7 0.4 0 0.4 0.4 19 5 15 305 15 0 15 0 -23.4 0 -23.2 -23.4 03/02/2005 08:50:00 15.8 1.7 19.5 10.7 15.5 1.7 19.9 10.7 0.4 0 0.4 0.4 17 5 11 305 15 0 15 0 -23.4 0 -22.9 -23.6 03/02/2005 09:00:00 16.1 1.8 20.2 11.1 15.8 1.8 19.9 10.7 0.4 0 0.4 0.4 17 5 19 305 15 0 15 0 -23.4 0 -23.2 -23.6 03/02/2005 09:10:00 14.4 1.6 17.9 10.7 14 1.5 18.3 9.9 0.4 0 0.4 0.4 12 6 12 305 15 0 15 0 -23.3 0 -23.2 -23.4 03/02/2005 09:20:00 14.3 1.7 17.6 9.9 14.1 1.7 17.9 10.3 0.4 0 0.4 0.4 12 6 9 305 15 0 15 0 -23.4 0 -22.9 -23.6 03/02/2005 09:30:00 14.7 1.7 18.3 10.3 14.5 1.7 18.7 10.3 0.4 0 0.4 0.4 12 5 5 305 15 0 15 0 -23.4 0 -23.2 -23.4 03/02/2005 09:40:00 14.4 1.5 17.9 10.7 14.1 1.5 17.6 11.1 0.4 0 0.4 0.4 13 5 13 305 15 0 15 0 -23.4 0 -23.2 -23.6 03/02/2005 09:50:00 14.1 1.7 17.9 10.3 13.9 1.7 17.9 9.9 0.4 0 0.4 0.4 11 5 4 305 15 0 15 0 -23.4 0 -23.2 -23.4 03/02/2005 10:00:00 14.5 1.6 19.1 10.7 14.6 1.5 18.7 10.3 0.4 0 0.4 0.4 12 6 14 305 15 0 15 0 -23.1 0.1 -22.9 -23.4 03/02/2005 10:10:00 13.6 1.9 17.9 8.8 13.4 1.7 17.6 8 0.4 0 0.4 0.4 12 6 4 305 15 0 15 0 -23.1 0 -23 -23.4 03/02/2005 10:20:00 15 1.9 19.9 11.1 14.8 1.8 19.9 10.7 0.4 0 0.4 0.4 13 6 18 305 15 0 15 0 -23.3 0 -23.2 -23.4 03/02/2005 10:30:00 14 1.9 18.3 9.5 13.8 1.8 18.3 9.9 0.4 0 0.4 0.4 11 6 8 305 15 0 15 0 -23.4 0.1 -23 -23.7 03/02/2005 10:40:00 12.7 1.6 16.4 9.5 12.6 1.5 17.2 9.5 0.4 0 0.4 0.4 6 6 11 305 15 0 15 0 -23.7 0.2 -23.2 -23.9 03/02/2005 10:50:00 13.1 1.3 16.4 9.9 13.1 1.3 16.8 9.9 0.4 0 0.4 0.4 9 6 9 305 15 0 15 0 -23.7 0.1 -23.4 -23.9 03/02/2005 11:00:00 13.1 1.3 16.8 9.9 12.9 1.3 16.8 9.9 0.4 0 0.4 0.4 11 5 2 305 15 0 15 0 -23.8 0 -23.6 -23.9 03/02/2005 11:10:00 13.3 2.1 17.9 9.1 13.1 2 17.6 9.1 0.4 0 0.4 0.4 11 6 16 305 15 0 15 0 -23.6 0.1 -23.4 -23.9 03/02/2005 11:20:00 12 1.5 15.6 9.1 11.9 1.5 16.1 8.8 0.4 0 0.4 0.4 8 5 7 305 15 0 15 0 -23.5 0 -23.4 -23.6 03/02/2005 11:30:00 13.4 1.3 16.1 10.3 13.1 1.3 16.4 10.3 0.4 0 0.4 0.4 12 6 5 305 15 0 15 0 -23.5 0 -22.9 -23.6 03/02/2005 11:40:00 12.8 1.1 15.6 9.5 12.7 1.1 15.3 9.9 0.4 0 0.4 0.4 14 6 9 305 16 0 15 0 -23.4 0 -23.2 -23.6 03/02/2005 11:50:00 12.8 1.4 16.1 9.9 12.6 1.4 15.6 9.1 0.4 0 0.4 0.4 12 5 8 305 16 0 16 0 -23.3 0 -23.2 -23.4 03/02/2005 12:00:00 12.3 1.5 16.4 9.1 12.1 1.5 16.1 9.1 0.4 0 0.4 0.4 18 6 22 305 17 0 16 0 -22.9 0 -22.7 -23.2 03/02/2005 12:10:00 12 1.5 15.6 8.8 11.7 1.5 16.1 7.6 0.4 0 0.4 0.4 17 6 13 305 17 0 18 0 -22.6 0.1 -22.4 -22.9 03/02/2005 12:20:00 11.4 1.3 14.5 8 11.3 1.3 14.1 8 0.4 0 0.4 0.4 16 6 15 305 18 0 18 0 -22.4 0 -22.2 -22.5 03/02/2005 12:30:00 12.3 1.3 15.6 8.8 12.2 1.4 16.1 8.4 0.4 0 0.4 0.4 13 7 24 305 18 0 19 0 -22.8 0.4 -22.2 -23.4 03/02/2005 12:40:00 11.5 1.5 14.5 7.6 11.4 1.5 14.9 8 0.4 0 0.4 0.4 15 6 11 305 18 0 18 0 -23.1 0.1 -22.9 -23.4 03/02/2005 12:50:00 11.7 1.7 17.2 7.6 11.5 1.7 17.2 7.2 0.4 0 0.4 0.4 19 7 16 305 18 0 19 0 -22.9 0 -22.5 -23 03/02/2005 13:00:00 11.8 1.2 14.5 7.6 11.8 1.2 14.5 7.6 0.4 0 0.4 0.4 12 6 20 305 19 0 19 0 -22.8 0 -22.5 -22.9 03/02/2005 13:10:00 10.2 1.2 14.1 7.6 10.2 1.2 13.3 7.6 0.4 0 0.4 0.4 11 6 8 305 19 0 19 0 -22.7 0 -22.5 -22.9 03/02/2005 13:20:00 9.9 1.4 13 6.8 9.7 1.4 12.6 6.5 0.4 0 0.4 0.4 12 6 13 305 19 0 19 0 -22.5 0.1 -22.4 -22.7 03/02/2005 13:30:00 10.1 1.1 13.3 7.6 10 1.2 13 7.6 0.4 0 0.4 0.4 11 6 10 305 19 0 19 0 -22.3 0 -22 -22.5 03/02/2005 13:40:00 10.7 1.3 13.7 8 10.6 1.3 13.7 8 0.4 0 0.4 0.4 11 6 8 305 20 0 20 0 -22.1 0 -21.8 -22.4 03/02/2005 13:50:00 11.7 1.3 15.6 8 11.7 1.4 14.9 7.6 0.4 0 0.4 0.4 11 6 12 305 20 0 20 0 -22.1 0.1 -21.8 -22.4 03/02/2005 14:00:00 12.7 1.3 15.6 9.1 12.8 1.3 16.4 9.1 0.4 0 0.4 0.4 15 5 11 305 20 0 20 0 -22.2 0 -21.8 -22.4 03/02/2005 14:10:00 11.4 1.5 15.3 8.4 11.4 1.3 14.5 8.4 0.4 0 0.4 0.4 13 6 16 305 20 0 20 0 -22 0 -21.7 -22.2 03/02/2005 14:20:00 10.7 1.2 13.3 8 10.6 1.2 13.7 7.6 0.4 0 0.4 0.4 9 6 9 305 20 0 20 0 -21.9 0.1 -21.7 -22 03/02/2005 14:30:00 11.2 1.2 14.1 7.6 11.1 1.3 14.1 8 0.4 0 0.4 0.4 13 6 8 305 20 0 21 0 -21.7 0 -21.5 -21.8 03/02/2005 14:40:00 12.4 1.3 15.3 8 12.4 1.3 15.3 8 0.4 0 0.4 0.4 13 5 9 305 21 0 21 0 -21.6 0 -21.3 -21.8 03/02/2005 14:50:00 12.4 1.7 16.8 8 12.6 1.7 17.2 8.8 0.4 0 0.4 0.4 14 6 18 305 21 0 21 0 -21.4 0.1 -21 -21.7 03/02/2005 15:00:00 12.5 1.7 16.1 8.4 12.4 1.7 15.6 8.4 0.4 0 0.4 0.4 11 8 5 305 21 0 22 0 -21.5 0.2 -20.8 -21.8 03/02/2005 15:10:00 12.9 1.9 18.3 8.8 12.8 1.9 17.6 8.8 0.4 0 0.4 0.4 17 6 18 305 21 0 21 0 -21.9 0.1 -21.7 -22 03/02/2005 15:20:00 11.6 1.5 14.5 8.4 11.5 1.6 15.6 8 0.4 0 0.4 0.4 18 6 13 305 21 0 21 0 -21.7 0.1 -21.3 -22 03/02/2005 15:30:00 10.8 1.2 13.7 7.6 10.8 1.2 14.1 7.2 0.4 0 0.4 0.4 17 5 21 305 21 0 20 0 -21.7 0.2 -21.3 -22 03/02/2005 15:40:00 11 1.2 14.5 8.4 11 1.2 15.3 8.4 0.4 0 0.4 0.4 19 7 24 305 21 0 22 0 -21.3 0 -21 -21.3 03/02/2005 15:50:00 11.6 1.3 15.3 8.4 11.5 1.3 14.9 8.4 0.4 0 0.4 0.4 17 6 19 305 22 0 22 0 -21.3 0 -21 -21.3 03/02/2005 16:00:00 10.8 1.5 15.6 7.2 10.8 1.4 14.9 7.6 0.4 0 0.4 0.4 19 7 27 305 23 0 23 0 -21.1 0.1 -20.8 -21.3 03/02/2005 16:10:00 11.5 1.4 15.6 8.4 11.4 1.3 15.3 8.8 0.4 0 0.4 0.4 19 7 21 305 24 0 24 0 -21.1 0.1 -20.8 -21.3 03/02/2005 16:20:00 11.8 1.5 15.6 8.4 11.8 1.5 14.9 7.6 0.4 0 0.4 0.4 21 6 15 305 25 0 25 0 -21.2 0 -20.8 -21.3 03/02/2005 16:30:00 11.8 1.5 15.6 8 11.7 1.6 15.6 8.4 0.4 0 0.4 0.4 22 7 17 305 25 0 26 0 -21.3 0 -21 -21.3 03/02/2005 16:40:00 10.2 1.3 13.7 6.8 10.1 1.3 14.1 6.5 0.4 0 0.4 0.4 18 6 23 305 26 0 26 0 -21.2 0 -20.8 -21.3 03/02/2005 16:50:00 10.7 1.2 14.1 7.6 10.6 1.3 14.1 6.8 0.4 0 0.4 0.4 14 6 8 305 26 0 26 0 -21.3 0.1 -21 -21.8 03/02/2005 17:00:00 11.3 1.3 14.1 7.6 11.2 1.2 14.1 8.4 0.4 0 0.4 0.4 14 5 12 305 25 0 26 0 -21.7 0 -21.3 -21.8 03/02/2005 17:10:00 10.7 1.3 14.1 7.2 10.7 1.3 14.1 7.6 0.4 0 0.4 0.4 18 6 20 305 24 0 25 0 -21.9 0 -21.7 -22 03/02/2005 17:20:00 10.3 1.3 13.7 6.8 10.3 1.3 13.7 6.8 0.4 0 0.4 0.4 11 6 16 305 23 0 23 0 -21.7 0.2 -21.3 -22 03/02/2005 17:30:00 11.4 1.5 15.6 8 11.4 1.5 16.1 7.6 0.4 0 0.4 0.4 16 6 12 305 22 0 22 0 -21.6 0.1 -21.3 -21.8 03/02/2005 17:40:00 13.7 1.3 16.8 9.5 13.7 1.2 16.4 9.5 0.4 0 0.4 0.4 18 5 20 305 22 0 22 0 -21.8 0 -21.5 -21.8 03/02/2005 17:50:00 13.6 1.2 16.8 10.3 13.4 1.3 16.8 9.9 0.4 0 0.4 0.4 19 5 17 305 21 0 21 0 -21.7 0 -21.5 -21.8 03/02/2005 18:00:00 14.5 1.4 18.7 10.7 14.2 1.5 17.9 9.5 0.4 0 0.4 0.4 19 6 22 305 21 0 21 0 -21.8 0 -21.5 -21.8 03/02/2005 18:10:00 13.1 1.3 16.1 9.1 12.9 1.3 16.8 9.1 0.4 0 0.4 0.4 16 7 14 305 20 0 20 0 -21.8 0 -21.5 -21.8 03/02/2005 18:20:00 11.7 1.7 15.3 8 11.6 1.7 14.9 7.6 0.4 0 0.4 0.4 8 6 4 305 19 0 19 0 -21.8 0 -21.5 -22 03/02/2005 18:30:00 11.7 1.2 14.5 8.4 11.6 1.2 14.1 8.4 0.4 0 0.4 0.4 6 5 5 305 19 0 19 0 -21.9 0 -21.7 -22 03/02/2005 18:40:00 11.3 1.5 14.9 6.8 11.3 1.4 14.1 7.2 0.4 0 0.4 0.4 5 5 5 305 19 0 19 0 -21.9 0 -21.8 -22 03/02/2005 18:50:00 12.2 1.1 14.1 9.1 12.1 1.1 14.1 9.1 0.4 0 0.4 0.4 4 5 5 305 19 0 19 0 -22.1 0.1 -21.8 -22.4 03/02/2005 19:00:00 11.6 1.2 14.5 8.4 11.6 1.2 14.5 8.4 0.4 0 0.4 0.4 1 5 4 305 18 0 18 0 -22.3 0 -22 -22.5 03/02/2005 19:10:00 11.2 0.9 13.3 8.4 11.1 1 13.3 8.8 0.4 0 0.4 0.4 3 5 10 305 18 0 18 0 -22.4 0 -21.8 -22.5 03/02/2005 19:20:00 10.3 1 12.2 7.6 10.4 1 12.6 7.6 0.4 0 0.4 0.4 358 5 355 305 17 0 17 0 -22.4 0 -22.2 -22.5 03/02/2005 19:30:00 10.8 0.9 13 8.4 10.9 1 13.3 8.4 0.4 0 0.4 0.4 357 4 352 305 17 0 17 0 -22.4 0 -22.4 -22.5 03/02/2005 19:40:00 11.1 1.2 13.7 7.2 11.1 1.2 14.1 8.4 0.4 0 0.4 0.4 359 5 355 305 17 0 17 0 -22.4 0 -22.2 -22.5 03/02/2005 19:50:00 11.5 1.2 13.7 8 11.5 1.1 14.1 8.8 0.4 0 0.4 0.4 2 5 3 305 17 0 17 0 -22.4 0 -22.2 -22.5 03/02/2005 20:00:00 11.6 0.9 13.3 8.4 11.8 0.9 13.7 9.5 0.4 0 0.4 0.4 2 4 2 305 17 0 16 0 -22.4 0 -21.8 -22.5 03/02/2005 20:10:00 11.5 1.1 14.1 9.1 11.5 1.1 14.1 8.8 0.4 0 0.4 0.4 2 5 3 305 16 0 16 0 -22.4 0 -22.2 -22.5 03/02/2005 20:20:00 10.8 1.1 13.7 8 10.9 1.1 13.7 8.4 0.4 0 0.4 0.4 2 5 2 305 16 0 16 0 -22.3 0 -22 -22.5 03/02/2005 20:30:00 10.7 1.3 13.3 7.6 10.9 1.3 14.1 7.6 0.4 0 0.4 0.4 0 5 3 305 16 0 16 0 -22.4 0 -22.2 -22.5 03/02/2005 20:40:00 10.3 1.3 12.6 6.8 10.4 1.3 13.3 7.2 0.4 0 0.4 0.4 3 5 357 305 16 0 16 0 -22.3 0.1 -21.8 -22.5 03/02/2005 20:50:00 10.7 1 13.3 8 10.9 1 13.7 8.4 0.4 0 0.4 0.4 2 5 3 305 16 0 16 0 -22.1 0 -21.8 -22.2 03/02/2005 21:00:00 11.4 1.2 14.5 8.4 11.4 1.3 14.9 8.4 0.4 0 0.4 0.4 8 5 11 305 17 0 17 0 -21.8 0.1 -21.5 -22 03/02/2005 21:10:00 10.7 1.2 13.3 6.8 10.6 1.2 14.1 6.8 0.4 0 0.4 0.4 9 5 18 305 17 0 17 0 -21.6 0 -21.1 -21.7 03/02/2005 21:20:00 9.6 1.1 12.2 7.2 9.5 1.2 13 6.8 0.4 0 0.4 0.4 11 7 4 305 17 0 17 0 -21.6 0 -21.1 -21.8 03/02/2005 21:30:00 11.4 1.1 14.5 8.4 11.3 1 14.1 8.4 0.4 0 0.4 0.4 11 5 18 305 17 0 17 0 -21.6 0 -21.5 -21.8 03/02/2005 21:40:00 11.3 1.1 13.7 8.4 11.3 1.1 14.1 8 0.4 0 0.4 0.4 13 5 17 305 17 0 17 0 -21.7 0 -21.5 -21.8 03/02/2005 21:50:00 9.9 1.1 12.6 6.8 9.9 1.2 12.6 7.2 0.4 0 0.4 0.4 12 5 9 305 17 0 17 0 -21.7 0 -21.3 -21.8 03/02/2005 22:00:00 11.1 1.1 14.5 8.4 11.2 1.1 13.7 8.4 0.4 0 0.4 0.4 10 5 10 305 17 0 17 0 -21.8 0 -21.7 -21.8 03/02/2005 22:10:00 11.5 1.2 14.9 8 11.4 1.2 14.9 8 0.4 0 0.4 0.4 9 5 11 305 17 0 17 0 -21.8 0 -21.8 -22 03/02/2005 22:20:00 11.2 1.2 14.1 8 11 1.3 14.1 7.6 0.4 0 0.4 0.4 9 5 10 305 17 0 17 0 -21.8 0 -21.7 -22 03/02/2005 22:30:00 12.3 1.2 15.3 8.8 12.1 1.2 15.3 9.1 0.4 0 0.4 0.4 9 5 16 305 17 0 17 0 -21.7 0 -21.5 -21.8 03/02/2005 22:40:00 12.9 1.1 16.1 9.9 12.7 1.2 15.6 9.5 0.4 0 0.4 0.4 9 5 10 305 17 0 17 0 -21.6 0 -21.3 -21.8 03/02/2005 22:50:00 12.1 1.4 15.3 8.4 11.9 1.3 15.3 8.4 0.4 0 0.4 0.4 9 5 11 305 17 0 17 0 -21.6 0 -21.3 -21.7 03/02/2005 23:00:00 10.6 1.2 13.7 7.6 10.6 1.2 14.1 8 0.4 0 0.4 0.4 7 5 14 305 17 0 17 0 -21.4 0 -21.3 -21.5 03/02/2005 23:10:00 11.1 1.2 14.1 8 11.1 1.2 13.7 8 0.4 0 0.4 0.4 7 5 8 305 17 0 17 0 -21.3 0 -21.1 -21.5 03/02/2005 23:20:00 11.6 1.3 14.5 8.4 11.5 1.5 14.9 8.4 0.4 0 0.4 0.4 8 5 12 305 18 0 18 0 -21.3 0 -21.1 -21.5 03/02/2005 23:30:00 10.3 1.6 14.5 6.1 10.1 1.5 13.7 6.5 0.4 0 0.4 0.4 8 6 5 305 18 0 18 0 -21.3 0 -21.3 -21.5 03/02/2005 23:40:00 9.8 1 11.8 7.6 9.8 1.1 12.6 7.2 0.4 0 0.4 0.4 5 6 10 305 18 0 18 0 -21.5 0.1 -21.3 -21.7 03/02/2005 23:50:00 9.3 1.1 11.8 6.5 9.1 1.1 11.8 6.5 0.4 0 0.4 0.4 5 5 4 305 17 0 18 0 -21.6 0 -21.3 -21.7 03/03/2005 00:00:00 10.2 1.1 13.7 7.2 10.2 1.1 13.3 7.2 0.4 0 0.4 0.4 10 5 5 305 18 0 18 0 -21.3 0 -21.1 -21.7 03/03/2005 00:10:00 11 1.2 13.7 8 10.9 1.1 13.7 8.4 0.4 0 0.4 0.4 8 5 3 305 18 0 18 0 -21.4 0 -21.3 -21.5 03/03/2005 00:20:00 10.7 1.5 14.5 7.6 10.5 1.4 14.1 7.2 0.4 0 0.4 0.4 4 5 0 305 18 0 18 0 -21.4 0 -21.3 -21.7 03/03/2005 00:30:00 10.4 1.3 13.7 7.6 10.4 1.3 13.3 7.6 0.4 0 0.4 0.4 4 5 7 305 18 0 18 0 -21.6 0.1 -21.3 -21.8 03/03/2005 00:40:00 10.7 1.3 13.3 7.6 10.7 1.3 14.5 7.6 0.4 0 0.4 0.4 4 5 0 305 17 0 18 0 -21.6 0 -21.3 -21.7 03/03/2005 00:50:00 10.5 1.5 14.9 7.6 10.4 1.5 14.9 7.6 0.4 0 0.4 0.4 4 6 4 305 17 0 17 0 -21.5 0 -21.3 -21.7 03/03/2005 01:00:00 11 1.1 13.3 8.4 11 1.1 13.7 8.4 0.4 0 0.4 0.4 3 5 10 305 17 0 18 0 -21.5 0 -21.3 -21.7 03/03/2005 01:10:00 11 1.2 14.1 7.6 11 1.2 13.7 8 0.4 0 0.4 0.4 2 5 10 305 17 0 17 0 -21.6 0 -21.3 -21.7 03/03/2005 01:20:00 10.5 1.2 14.1 7.6 10.5 1.2 13.7 7.6 0.4 0 0.4 0.4 1 6 356 305 17 0 17 0 -21.6 0 -21.5 -21.7 03/03/2005 01:30:00 10.4 1 13.3 8 10.3 1.1 13.3 8.4 0.4 0 0.4 0.4 2 6 5 305 17 0 17 0 -21.7 0 -21.5 -21.8 03/03/2005 01:40:00 10.3 1 13 8 10.3 1 13 7.6 0.4 0 0.4 0.4 4 5 2 305 17 0 17 0 -21.6 0 -21.3 -21.7 03/03/2005 01:50:00 11.1 1.2 13.7 7.2 11 1.2 14.1 8 0.4 0 0.4 0.4 4 5 7 305 17 0 17 0 -21.5 0 -21.3 -21.7 03/03/2005 02:00:00 10.1 1.1 13.3 7.6 10.1 1.1 13.3 7.2 0.4 0 0.4 0.4 2 6 359 305 18 0 18 0 -21.3 0 -21.3 -21.5 03/03/2005 02:10:00 9 1.3 13.3 6.1 9 1.3 13 6.5 0.4 0 0.4 0.4 5 6 7 305 18 0 18 0 -21.2 0.1 -21 -21.5 03/03/2005 02:20:00 11.8 1.7 15.6 6.5 11.8 1.7 16.1 7.6 0.4 0 0.4 0.4 8 5 2 305 18 0 18 0 -20.8 0.1 -20.4 -21.1 03/03/2005 02:30:00 12.4 1.3 15.3 9.5 12.3 1.3 15.3 8.4 0.4 0 0.4 0.4 7 6 9 305 18 0 18 0 -20.7 0 -20.4 -21 03/03/2005 02:40:00 11.7 1.2 14.9 8.8 11.7 1.2 14.5 8.4 0.4 0 0.4 0.4 4 5 9 305 19 0 19 0 -21 0.1 -20.8 -21.3 03/03/2005 02:50:00 11.7 1.1 14.9 9.1 11.6 1.1 14.9 8.4 0.4 0 0.4 0.4 5 5 11 305 18 0 19 0 -21.2 0 -21 -21.3 03/03/2005 03:00:00 11.2 1 13.7 8.4 11.1 1 13.3 8.4 0.4 0 0.4 0.4 6 5 7 305 18 0 18 0 -21.3 0 -21 -21.3 03/03/2005 03:10:00 10.8 1.3 14.5 7.6 10.7 1.3 14.5 8 0.4 0 0.4 0.4 8 5 11 305 18 0 18 0 -21.3 0 -21 -21.3 03/03/2005 03:20:00 10.9 1.7 14.5 7.2 10.8 1.7 15.3 7.2 0.4 0 0.4 0.4 9 6 5 305 18 0 18 0 -21.3 0 -21 -21.3 03/03/2005 03:30:00 11.4 1.3 15.6 8 11.5 1.2 14.9 8 0.4 0 0.4 0.4 10 5 9 305 18 0 18 0 -21.2 0 -20.8 -21.3 03/03/2005 03:40:00 11.1 1.5 14.9 7.6 11 1.3 14.1 8 0.4 0 0.4 0.4 10 5 11 305 18 0 18 0 -21.2 0 -21 -21.3 03/03/2005 03:50:00 11.2 1.2 13.7 8.4 11.1 1.3 14.5 7.6 0.4 0 0.4 0.4 10 5 7 305 18 0 18 0 -21.2 0 -21 -21.3 03/03/2005 04:00:00 11.6 1 14.1 8.8 11.5 1.1 14.5 8.8 0.4 0 0.4 0.4 9 5 8 305 18 0 18 0 -21.2 0 -21 -21.3 03/03/2005 04:10:00 11.5 1.6 14.9 8 11.5 1.5 15.6 8 0.4 0 0.4 0.4 9 5 11 305 18 0 18 0 -21.3 0 -21 -21.5 03/03/2005 04:20:00 12.6 1.3 16.1 9.9 12.4 1.4 16.1 9.1 0.4 0 0.4 0.4 11 4 8 305 18 0 18 0 -21.3 0 -21.3 -21.7 03/03/2005 04:30:00 12.4 1.5 15.6 8.8 12.2 1.5 15.6 8.4 0.4 0 0.4 0.4 12 6 12 305 18 0 18 0 -21.4 0.1 -21.3 -21.7 03/03/2005 04:40:00 12.6 1.1 15.6 8.8 12.4 1.2 15.6 9.1 0.4 0 0.4 0.4 10 5 12 305 18 0 18 0 -21.6 0 -21.3 -21.7 03/03/2005 04:50:00 13.4 1.7 17.6 9.1 13.3 1.7 17.6 8.8 0.4 0 0.4 0.4 12 5 11 305 17 0 17 0 -21.6 0 -21.5 -21.8 03/03/2005 05:00:00 14.1 1.5 17.6 9.5 13.8 1.6 17.6 8.8 0.4 0 0.4 0.4 12 5 14 305 17 0 17 0 -21.7 0 -21.5 -21.8 03/03/2005 05:10:00 13.2 1.5 16.4 10.3 13.2 1.4 16.8 9.9 0.4 0 0.4 0.4 13 5 18 305 17 0 17 0 -21.7 0 -21.5 -21.8 03/03/2005 05:20:00 13.7 1.6 17.6 9.9 13.6 1.5 17.6 10.3 0.4 0 0.4 0.4 14 5 14 305 17 0 17 0 -21.7 0 -21.7 -21.8 03/03/2005 05:30:00 13 1.6 17.6 9.1 13 1.5 16.8 8.4 0.4 0 0.4 0.4 12 5 12 305 17 0 17 0 -21.7 0 -21.5 -21.8 03/03/2005 05:40:00 12.9 1.3 16.1 9.1 12.8 1.3 16.4 9.5 0.4 0 0.4 0.4 12 5 10 305 17 0 17 0 -21.8 0 -21.7 -21.8 03/03/2005 05:50:00 12.3 1.5 15.6 8.8 12.1 1.5 16.4 9.1 0.4 0 0.4 0.4 13 6 12 305 17 0 17 0 -21.7 0 -21.5 -21.8 03/03/2005 06:00:00 12.5 1.5 16.4 8.4 12.5 1.5 16.1 8.8 0.4 0 0.4 0.4 12 5 5 305 17 0 17 0 -21.7 0.1 -21.5 -21.8 03/03/2005 06:10:00 12.4 1.2 16.1 9.5 12.3 1.3 16.1 9.1 0.4 0 0.4 0.4 12 5 13 305 17 0 17 0 -21.6 0 -21.3 -21.7 03/03/2005 06:20:00 12.7 1.5 16.4 9.1 12.5 1.5 16.1 9.5 0.4 0 0.4 0.4 12 6 13 305 17 0 17 0 -21.5 0 -21.3 -21.7 03/03/2005 06:30:00 12.3 1.2 15.6 9.1 12.2 1.2 14.9 9.1 0.4 0 0.4 0.4 12 5 20 305 17 0 17 0 -21.5 0 -21.3 -21.7 03/03/2005 06:40:00 13.3 1.3 16.4 8.4 12.9 1.5 16.4 8.8 0.4 0 0.4 0.4 15 6 10 305 17 0 17 0 -21.6 0 -21.3 -21.7 03/03/2005 06:50:00 13.7 1.5 17.2 10.3 13.5 1.5 17.2 9.5 0.4 0 0.4 0.4 15 5 8 305 17 0 17 0 -21.4 0 -21.3 -21.7 03/03/2005 07:00:00 13.7 1.9 17.6 9.1 13.5 1.9 17.6 9.1 0.4 0 0.4 0.4 15 5 18 305 18 0 18 0 -21.3 0 -21.1 -21.3 03/03/2005 07:10:00 13.8 1.6 17.9 9.9 13.6 1.6 17.6 9.9 0.4 0 0.4 0.4 14 5 16 305 18 0 18 0 -21.2 0 -21 -21.3 03/03/2005 07:20:00 12.6 1.3 16.1 9.5 12.4 1.3 16.1 9.9 0.4 0 0.4 0.4 14 6 13 305 18 0 18 0 -21 0 -20.8 -21.3 03/03/2005 07:30:00 12.7 1.3 15.6 9.5 12.6 1.3 16.1 8.8 0.4 0 0.4 0.4 14 6 9 305 18 0 18 0 -20.9 0 -20.8 -21.1 03/03/2005 07:40:00 13.4 1.5 17.2 9.1 13.3 1.6 16.8 8.4 0.4 0 0.4 0.4 13 5 12 305 18 0 18 0 -20.9 0 -20.8 -21 03/03/2005 07:50:00 13 1.3 16.4 9.5 13.1 1.3 16.4 9.1 0.4 0 0.4 0.4 14 5 18 305 19 0 19 0 -20.8 0 -20.6 -21 03/03/2005 08:00:00 13.3 1.4 16.8 9.1 13.2 1.3 16.8 9.9 0.4 0 0.4 0.4 16 5 11 305 19 0 19 0 -20.8 0.1 -20.6 -21.1 03/03/2005 08:10:00 13.3 1.4 16.4 10.3 13.2 1.4 17.2 9.9 0.4 0 0.4 0.4 15 5 13 305 19 0 19 0 -20.8 0 -20.6 -21 03/03/2005 08:20:00 13.1 1.5 16.8 9.1 13 1.7 16.8 9.1 0.4 0 0.4 0.4 16 5 11 305 19 0 19 0 -20.7 0 -20.4 -21 03/03/2005 08:30:00 12.9 1.7 16.8 8.4 12.8 1.7 16.8 8.8 0.4 0 0.4 0.4 16 5 19 305 19 0 19 0 -20.6 0.1 -20.1 -20.8 03/03/2005 08:40:00 12.3 1.2 14.9 8.8 12.3 1.2 15.3 9.5 0.4 0 0.4 0.4 16 5 14 305 19 0 19 0 -20.5 0.1 -20.1 -20.8 03/03/2005 08:50:00 12.3 1.2 15.3 8.8 12.3 1.2 15.6 9.1 0.4 0 0.4 0.4 14 5 9 305 20 0 19 0 -20.4 0.1 -20.1 -20.8 03/03/2005 09:00:00 13.1 1.9 16.4 8.8 13 1.9 16.8 8.8 0.4 0 0.4 0.4 13 5 11 305 20 0 20 0 -20.5 0.1 -20.1 -20.8 03/03/2005 09:10:00 13.4 1.7 17.2 9.9 13.3 1.8 17.2 9.1 0.4 0 0.4 0.4 14 5 13 305 20 0 20 0 -20.6 0.1 -20.1 -20.8 03/03/2005 09:20:00 13 1.7 16.8 9.1 13 1.7 16.4 8.4 0.4 0 0.4 0.4 14 5 19 305 20 0 20 0 -20.5 0 -20.1 -20.6 03/03/2005 09:30:00 12.8 1.5 16.4 8.8 12.8 1.4 16.8 9.5 0.4 0 0.4 0.4 15 6 11 305 20 0 20 0 -20.5 0 -20.1 -20.6 03/03/2005 09:40:00 13.3 1.5 17.2 9.9 13.2 1.5 16.8 9.9 0.4 0 0.4 0.4 15 5 9 305 20 0 20 0 -20.4 0 -20.1 -20.6 03/03/2005 09:50:00 13.5 1.3 17.2 9.9 13.5 1.3 16.4 9.9 0.4 0 0.4 0.4 14 4 11 305 20 0 20 0 -20.5 0 -20.1 -20.6 03/03/2005 10:00:00 13.7 1.3 17.2 10.3 13.6 1.4 16.8 9.9 0.4 0 0.4 0.4 11 5 11 305 20 0 20 0 -20.6 0 -20.2 -20.8 03/03/2005 10:10:00 12.7 1.2 16.1 9.9 12.7 1.4 16.8 9.5 0.4 0 0.4 0.4 13 6 11 305 20 0 20 0 -20.6 0 -20.2 -20.8 03/03/2005 10:20:00 13.6 1.3 16.4 9.9 13.7 1.4 17.2 10.3 0.4 0 0.4 0.4 13 5 8 305 20 0 20 0 -20.5 0 -20.1 -20.8 03/03/2005 10:30:00 13.4 1.3 16.1 10.3 13.4 1.4 16.8 10.3 0.4 0 0.4 0.4 16 5 11 305 20 0 20 0 -20.3 0.1 -20.1 -20.6 03/03/2005 10:40:00 12.5 1.3 15.6 9.1 12.5 1.2 15.3 9.5 0.4 0 0.4 0.4 15 5 18 305 20 0 20 0 -20.2 0 -19.9 -20.1 03/03/2005 10:50:00 12.9 1.6 16.8 9.1 12.8 1.6 16.8 9.5 0.4 0 0.4 0.4 13 5 12 305 21 0 21 0 -20.1 0 -19.9 -20.1 03/03/2005 11:00:00 12.5 1.3 15.3 9.1 12.6 1.3 16.1 8.8 0.4 0 0.4 0.4 15 5 17 305 21 0 21 0 -20.1 0.1 -19.5 -20.1 03/03/2005 11:10:00 12.8 1.3 16.1 8.8 12.8 1.4 16.1 9.1 0.4 0 0.4 0.4 18 5 16 305 21 0 21 0 -20.1 0.1 -19.5 -20.1 03/03/2005 11:20:00 12.1 1.4 15.3 9.1 12.1 1.4 15.3 8.8 0.4 0 0.4 0.4 18 6 7 305 21 0 21 0 -20 0.1 -19.5 -20.1 03/03/2005 11:30:00 12.3 1.6 16.4 8 12.1 1.5 15.6 8.8 0.4 0 0.4 0.4 17 6 15 305 22 0 22 0 -19.9 0.1 -19.5 -20.1 03/03/2005 11:40:00 12.3 1.8 16.4 8.4 12 1.7 16.1 8 0.4 0 0.4 0.4 17 6 14 305 22 0 22 0 -19.9 0.1 -19.5 -20.1 03/03/2005 11:50:00 11.7 1.3 15.6 8.4 11.5 1.4 16.4 8.8 0.4 0 0.4 0.4 20 6 18 305 22 0 22 0 -19.7 0.1 -19.2 -19.9 03/03/2005 12:00:00 10.7 1.3 13.3 7.2 10.6 1.2 13.7 6.8 0.4 0 0.4 0.4 21 7 17 305 23 0 22 0 -19.6 0 -19.2 -19.7 03/03/2005 12:10:00 10.6 1.3 14.1 6.8 10.6 1.3 14.1 6.8 0.4 0 0.4 0.4 20 6 12 305 23 0 23 0 -19.6 0 -19.2 -19.7 03/03/2005 12:20:00 10.4 1.5 14.5 6.8 10.4 1.6 14.5 7.2 0.4 0 0.4 0.4 17 7 18 305 23 0 24 0 -19.6 0 -19.2 -19.7 03/03/2005 12:30:00 10.2 1.5 13.3 6.5 10.2 1.4 13 6.8 0.4 0 0.4 0.4 15 6 18 305 24 0 24 0 -19.7 0 -19.3 -19.9 03/03/2005 12:40:00 9.9 1.4 15.3 6.5 9.7 1.3 13.7 6.8 0.4 0 0.4 0.4 18 8 12 305 24 0 24 0 -19.6 0 -19 -19.9 03/03/2005 12:50:00 9.5 1.5 13.7 6.8 9.4 1.4 13.7 6.5 0.4 0 0.4 0.4 17 7 16 305 24 0 24 0 -19.5 0.1 -19 -19.5 03/03/2005 13:00:00 9.6 1.7 14.1 6.1 9.5 1.6 13.3 5.7 0.4 0 0.4 0.4 21 7 11 305 25 0 25 0 -19.4 0.1 -19 -19.5 03/03/2005 13:10:00 9.6 1.6 13.3 5.7 9.4 1.5 13 6.5 0.4 0 0.4 0.4 16 7 22 305 25 0 25 0 -19.4 0.1 -19 -19.5 03/03/2005 13:20:00 10 1.6 13.7 6.1 9.8 1.7 14.1 5.3 0.4 0 0.4 0.4 16 6 16 305 25 0 25 0 -19.4 0.1 -19 -19.5 03/03/2005 13:30:00 10.4 1.7 14.5 6.1 10.2 1.7 14.5 6.8 0.4 0 0.4 0.4 17 6 19 305 25 0 25 0 -19.5 0.1 -19 -19.5 03/03/2005 13:40:00 10.7 1.3 14.1 6.8 10.5 1.3 13.7 6.8 0.4 0 0.4 0.4 20 6 19 305 25 0 25 0 -19.3 0.1 -19 -19.5 03/03/2005 13:50:00 10.4 1.1 13.3 8 10.2 1.2 13.7 7.2 0.4 0 0.4 0.4 17 6 18 305 25 0 25 0 -19.3 0 -19 -19.5 03/03/2005 14:00:00 10.4 1.5 14.5 6.8 10.4 1.6 15.3 6.5 0.4 0 0.4 0.4 14 7 28 305 26 0 26 0 -19.2 0.1 -18.8 -19.5 03/03/2005 14:10:00 9.7 1.3 13.7 6.8 9.7 1.3 13.3 6.5 0.4 0 0.4 0.4 16 7 18 305 26 0 26 0 -19.1 0 -18.6 -19.3 03/03/2005 14:20:00 10.3 1.5 14.1 6.8 10.1 1.5 13.7 6.5 0.4 0 0.4 0.4 17 7 23 305 27 0 27 0 -19.1 0 -18.4 -19.2 03/03/2005 14:30:00 10.3 1.2 13.3 8 10.3 1.2 13.3 7.2 0.4 0 0.4 0.4 19 7 23 305 27 0 27 0 -19 0.1 -18.4 -19 03/03/2005 14:40:00 10.3 1.4 13.3 6.8 10.1 1.3 13.7 6.5 0.4 0 0.4 0.4 16 6 13 305 28 0 28 0 -19 0.1 -18.4 -19 03/03/2005 14:50:00 10.4 1.7 14.5 5.7 10.2 1.7 15.3 6.5 0.4 0 0.4 0.4 20 6 12 305 28 0 28 0 -19 0.1 -18.4 -19 03/03/2005 15:00:00 9.9 1.7 14.5 6.5 9.7 1.7 14.1 6.5 0.4 0 0.4 0.4 20 7 25 305 28 0 28 0 -18.8 0.1 -18.2 -19 03/03/2005 15:10:00 10 1.2 14.1 7.6 9.9 1.2 14.1 7.2 0.4 0 0.4 0.4 18 7 13 305 28 0 28 0 -18.8 0 -18.2 -19 03/03/2005 15:20:00 11.5 1.4 15.3 6.8 11.4 1.5 15.3 6.8 0.4 0 0.4 0.4 19 6 17 305 28 0 28 0 -18.8 0 -18.2 -19 03/03/2005 15:30:00 10.8 2.1 16.8 7.2 10.7 2.1 16.4 6.8 0.4 0 0.4 0.4 18 6 21 305 28 0 28 0 -18.7 0.1 -18.1 -19 03/03/2005 15:40:00 10.3 1.5 14.1 7.2 10.1 1.5 13.7 6.8 0.4 0 0.4 0.4 16 7 17 305 28 0 28 0 -18.6 0.1 -18.1 -18.8 03/03/2005 15:50:00 10.7 1.3 14.1 8 10.7 1.4 14.1 7.6 0.4 0 0.4 0.4 19 7 24 305 28 0 28 0 -18.6 0 -18.1 -18.8 03/03/2005 16:00:00 10.9 1.3 13.7 8.4 10.7 1.4 13.7 8 0.4 0 0.4 0.4 18 7 15 305 28 0 28 0 -18.5 0.1 -18.1 -18.6 03/03/2005 16:10:00 12.2 1.4 16.1 8.8 12 1.5 16.8 8.4 0.4 0 0.4 0.4 18 6 20 305 28 0 28 0 -18.6 0.1 -18.1 -18.8 03/03/2005 16:20:00 11.8 1.7 16.4 8 11.6 1.7 16.1 7.6 0.4 0 0.4 0.4 18 6 12 305 28 0 28 0 -18.5 0.1 -18.1 -18.6 03/03/2005 16:30:00 12.5 1.3 15.6 9.5 12.2 1.3 15.3 8.8 0.4 0 0.4 0.4 20 6 21 305 28 0 28 0 -18.5 0 -18.1 -18.6 03/03/2005 16:40:00 12 1.3 15.3 8.8 11.8 1.4 15.3 8.8 0.4 0 0.4 0.4 23 6 21 305 28 0 28 0 -18.4 0.1 -17.9 -18.6 03/03/2005 16:50:00 12.9 1.6 16.4 9.1 12.7 1.7 16.8 8.8 0.4 0 0.4 0.4 21 6 25 305 28 0 29 0 -18.1 0.1 -17.7 -18.2 03/03/2005 17:00:00 12.3 1.3 16.1 9.1 12.4 1.3 15.6 9.1 0.4 0 0.4 0.4 20 6 19 305 29 0 29 0 -18.2 0.1 -17.7 -18.4 03/03/2005 17:10:00 12.7 1.7 16.8 8.8 12.4 1.7 16.4 9.1 0.4 0 0.4 0.4 18 6 19 305 29 0 29 0 -18.2 0.1 -17.9 -18.4 03/03/2005 17:20:00 11.8 1.8 16.1 8.4 11.5 1.8 16.1 7.6 0.4 0 0.4 0.4 16 7 24 305 28 0 28 0 -18.1 0.1 -17.7 -18.4 03/03/2005 17:30:00 11.6 1.9 16.1 7.6 11.6 1.8 16.1 7.2 0.4 0 0.4 0.4 16 7 16 305 28 0 28 0 -18.2 0.1 -17.9 -18.4 03/03/2005 17:40:00 12.7 1.4 16.4 9.1 12.5 1.4 16.4 8.8 0.4 0 0.4 0.4 18 6 22 305 28 0 28 0 -18.2 0 -17.7 -18.4 03/03/2005 17:50:00 12 1.2 15.3 9.1 11.7 1.2 14.9 8.4 0.4 0 0.4 0.4 15 6 19 305 28 0 28 0 -18.1 0.1 -17.7 -18.2 03/03/2005 18:00:00 11.9 1.5 14.9 7.6 11.7 1.5 15.3 7.2 0.4 0 0.4 0.4 15 5 18 305 28 0 28 0 -18.1 0 -17.9 -18.4 03/03/2005 18:10:00 11.2 1.7 16.4 8 11.1 1.7 16.8 7.6 0.4 0 0.4 0.4 17 6 12 305 28 0 28 0 -18 0 -17.7 -18.2 03/03/2005 18:20:00 11 1.8 15.6 6.8 10.9 1.7 16.4 7.2 0.4 0 0.4 0.4 18 6 24 305 28 0 28 0 -18 0 -17.5 -18.1 03/03/2005 18:30:00 12.1 1.5 16.1 8.4 11.9 1.5 15.6 8 0.4 0 0.4 0.4 17 7 13 305 28 0 28 0 -18 0 -17.5 -18.1 03/03/2005 18:40:00 11.5 1.7 16.1 7.6 11.4 1.7 15.6 7.2 0.4 0 0.4 0.4 18 7 19 305 28 0 28 0 -18 0 -17.5 -18.1 03/03/2005 18:50:00 11.5 1.4 15.3 8 11.4 1.3 15.3 7.6 0.4 0 0.4 0.4 18 7 10 305 28 0 28 0 -18.1 0.1 -17.5 -18.4 03/03/2005 19:00:00 12.3 1.3 16.1 9.1 12.1 1.3 15.6 9.1 0.4 0 0.4 0.4 20 7 33 305 27 0 27 0 -18.1 0 -17.7 -18.2 03/03/2005 19:10:00 11.7 1.5 15.3 8 11.5 1.5 15.6 7.6 0.4 0 0.4 0.4 18 6 17 305 27 0 27 0 -18.1 0 -17.7 -18.2 03/03/2005 19:20:00 11.1 1.5 14.9 7.6 10.8 1.5 14.9 7.2 0.4 0 0.4 0.4 19 6 15 305 27 0 27 0 -18.1 0 -17.7 -18.2 03/03/2005 19:30:00 11.4 1.3 15.3 8 11.1 1.4 14.5 8 0.4 0 0.4 0.4 21 7 16 305 27 0 27 0 -17.9 0.1 -17.5 -18.1 03/03/2005 19:40:00 12.6 1.5 16.4 9.1 12.3 1.6 16.1 8.8 0.4 0 0.4 0.4 25 6 29 305 27 0 27 0 -17.9 0.1 -17.5 -18.1 03/03/2005 19:50:00 13 1.4 16.1 8.4 12.7 1.5 16.1 8.8 0.4 0 0.4 0.4 24 6 31 305 27 0 27 0 -17.8 0.1 -17.3 -18.1 03/03/2005 20:00:00 11.7 1.7 15.6 8 11.4 1.6 15.6 7.2 0.4 0 0.4 0.4 23 6 24 305 27 0 27 0 -17.9 0 -17.5 -18.1 03/03/2005 20:10:00 11.6 1.4 15.3 8.4 11.4 1.4 15.6 8.4 0.4 0 0.4 0.4 23 6 24 305 27 0 27 0 -17.8 0.1 -17.5 -18.1 03/03/2005 20:20:00 11.6 1.2 14.9 8.8 11.5 1.2 14.9 8.8 0.4 0 0.4 0.4 21 5 23 305 28 0 28 0 -17.5 0 -17.1 -17.7 03/03/2005 20:30:00 10.9 1.2 14.1 7.6 10.8 1.2 13.3 8 0.4 0 0.4 0.4 20 6 22 305 28 0 28 0 -17.4 0 -16.9 -17.5 03/03/2005 20:40:00 10 1.1 13 7.6 9.8 1.1 12.6 7.2 0.4 0 0.4 0.4 25 6 30 305 28 0 28 0 -16.9 0.2 -16.4 -17.3 03/03/2005 20:50:00 11.9 1.3 15.3 8.8 11.6 1.3 14.9 8.8 0.4 0 0.4 0.4 28 7 28 305 29 0 29 0 -16.7 0.2 -16 -16.9 03/03/2005 21:00:00 12.7 1.5 16.4 9.1 12.3 1.5 16.1 9.1 0.4 0 0.4 0.4 31 6 33 305 30 0 30 0 -16.5 0.1 -16 -16.6 03/03/2005 21:10:00 12.8 1.5 16.1 9.1 12.4 1.5 16.8 8.8 0.4 0 0.4 0.4 32 6 25 305 31 0 31 0 -16.5 0.1 -16 -16.7 03/03/2005 21:20:00 12.5 1.7 17.2 9.5 12.1 1.7 17.2 8.8 0.4 0 0.4 0.4 33 7 27 305 31 0 31 0 -16.5 0.1 -16 -16.7 03/03/2005 21:30:00 12 1.1 14.5 9.1 11.7 1.1 14.1 8.8 0.4 0 0.4 0.4 30 7 31 305 31 0 31 0 -16.6 0.1 -16 -16.9 03/03/2005 21:40:00 12.6 1.3 16.4 9.1 12.4 1.3 15.3 9.1 0.4 0 0.4 0.4 29 6 30 305 31 0 31 0 -16.6 0.1 -16 -16.9 03/03/2005 21:50:00 12.7 1.4 15.6 9.5 12.5 1.4 15.6 8.8 0.4 0 0.4 0.4 28 6 25 305 31 0 31 0 -16.6 0.1 -16.2 -16.9 03/03/2005 22:00:00 13.5 1.5 16.8 10.3 13.2 1.5 16.8 9.9 0.4 0 0.4 0.4 29 5 39 305 31 0 31 0 -16.7 0.2 -16.2 -16.9 03/03/2005 22:10:00 13.5 1.4 17.2 10.3 13.3 1.5 16.8 9.5 0.4 0 0.4 0.4 28 5 33 305 31 0 31 0 -16.8 0.1 -16.2 -16.9 03/03/2005 22:20:00 11.7 1.2 14.9 8.8 11.5 1.1 14.9 9.1 0.4 0 0.4 0.4 28 6 23 305 31 0 31 0 -16.8 0.1 -16.4 -16.9 03/03/2005 22:30:00 11.7 1.2 15.3 8.8 11.6 1.2 14.9 9.1 0.4 0 0.4 0.4 26 6 25 305 31 0 31 0 -16.7 0.1 -16.4 -16.9 03/03/2005 22:40:00 13.1 1.1 16.1 9.9 12.8 1.1 16.1 9.1 0.4 0 0.4 0.4 28 5 32 305 31 0 31 0 -16.7 0.1 -16.2 -16.9 03/03/2005 22:50:00 12.9 1.2 16.1 10.3 12.6 1.3 16.4 9.9 0.4 0 0.4 0.4 29 5 27 305 31 0 31 0 -16.7 0.1 -16.2 -16.9 03/03/2005 23:00:00 13.3 1.3 16.4 9.9 12.9 1.3 16.1 9.5 0.4 0 0.4 0.4 30 5 27 305 31 0 32 0 -16.8 0.1 -16.2 -16.9 03/03/2005 23:10:00 14.1 1.2 17.2 11.1 13.8 1.2 16.8 10.7 0.4 0 0.4 0.4 32 5 35 305 32 0 32 0 -16.8 0 -16.4 -16.9 03/03/2005 23:20:00 14.4 1.4 18.3 11.1 14.1 1.5 17.6 10.3 0.4 0 0.4 0.4 37 5 31 305 32 0 32 0 -16.8 0.1 -16.2 -16.9 03/03/2005 23:30:00 14.9 1.2 17.9 12.2 14.5 1.2 18.7 11.5 0.4 0 0.4 0.4 37 5 31 305 32 0 32 0 -16.8 0.1 -16.2 -16.9 03/03/2005 23:40:00 15.9 1.3 20.2 13 15.6 1.3 20.2 13 0.4 0 0.4 0.4 38 5 35 305 32 0 32 0 -16.7 0.1 -16.2 -16.9 03/03/2005 23:50:00 15.7 1.3 20.2 12.2 15.6 1.4 19.9 12.2 0.4 0 0.4 0.4 40 5 39 305 32 0 32 0 -16.7 0.1 -16 -16.9 03/04/2005 00:00:00 16 1.5 19.5 13 15.8 1.5 19.5 11.8 0.4 0 0.4 0.4 40 5 39 305 32 0 32 0 -16.6 0 -16 -16.9 03/04/2005 00:10:00 15.8 1.3 19.1 12.2 15.6 1.3 19.1 11.5 0.4 0 0.4 0.4 42 5 42 305 32 0 32 0 -16.5 0 -16 -16.6 03/04/2005 00:20:00 16.4 1.2 19.5 13 16.1 1.2 19.5 12.6 0.4 0 0.4 0.4 41 5 46 305 32 0 32 0 -16.6 0 -16 -16.7 03/04/2005 00:30:00 15.8 1.3 19.5 12.2 15.6 1.4 18.7 11.5 0.4 0 0.4 0.4 44 5 45 305 32 0 32 0 -16.6 0 -16 -16.7 03/04/2005 00:40:00 14.6 1.4 18.7 11.8 14.3 1.3 18.3 11.1 0.4 0 0.4 0.4 43 5 41 305 32 0 32 0 -16.5 0 -16 -16.6 03/04/2005 00:50:00 14.4 1.2 17.9 11.1 14.2 1.2 18.3 11.1 0.4 0 0.4 0.4 40 6 43 305 32 0 32 0 -16.5 0 -16 -16.6 03/04/2005 01:00:00 13.7 1.3 17.6 10.3 13.4 1.3 17.2 10.7 0.4 0 0.4 0.4 40 5 41 305 32 0 32 0 -16.4 0.1 -16 -16.6 03/04/2005 01:10:00 13 1.3 16.1 9.1 12.7 1.4 16.4 9.5 0.4 0 0.4 0.4 34 6 39 305 32 0 32 0 -16.4 0 -16 -16.6 03/04/2005 01:20:00 13.2 1.6 16.4 8.4 12.8 1.6 16.4 8.4 0.4 0 0.4 0.4 33 6 39 305 32 0 32 0 -16.5 0.1 -16 -16.6 03/04/2005 01:30:00 12.5 1.5 16.1 8.8 12.2 1.5 16.1 8 0.4 0 0.4 0.4 33 6 38 305 32 0 32 0 -16.4 0.1 -16 -16.6 03/04/2005 01:40:00 11.5 1.5 15.3 9.1 11.3 1.4 15.6 8.8 0.4 0 0.4 0.4 32 6 27 305 32 0 32 0 -16.4 0 -16 -16.6 03/04/2005 01:50:00 12.6 1.2 16.1 9.5 12.4 1.2 15.6 9.9 0.4 0 0.4 0.4 32 5 27 305 32 0 32 0 -16.5 0.1 -16 -16.7 03/04/2005 02:00:00 11.9 1.4 15.3 9.1 11.7 1.5 15.6 8.8 0.4 0 0.4 0.4 30 5 28 305 32 0 32 0 -16.6 0.1 -16 -16.7 03/04/2005 02:10:00 11.1 1.2 14.5 8 10.9 1.2 14.1 7.2 0.4 0 0.4 0.4 29 6 29 305 32 0 32 0 -16.6 0.1 -16 -16.9 03/04/2005 02:20:00 11.2 1.2 14.9 8.8 10.9 1.3 15.6 8.4 0.4 0 0.4 0.4 30 5 21 305 32 0 32 0 -16.6 0.1 -16.2 -16.9 03/04/2005 02:30:00 11.6 1.6 15.6 8 11.6 1.7 15.6 8.4 0.4 0 0.4 0.4 29 6 32 305 32 0 32 0 -16.6 0.1 -16 -16.9 03/04/2005 02:40:00 11.4 1.2 14.5 8.8 11.2 1.2 14.9 8.8 0.4 0 0.4 0.4 30 6 23 305 32 0 32 0 -16.6 0 -16 -16.7 03/04/2005 02:50:00 12.8 1.3 16.4 9.5 12.5 1.3 16.4 9.1 0.4 0 0.4 0.4 30 7 38 305 32 0 32 0 -16.6 0.1 -16 -16.7 03/04/2005 03:00:00 12.8 1.3 16.8 9.9 12.6 1.4 16.8 9.5 0.4 0 0.4 0.4 32 6 23 305 32 0 32 0 -16.5 0.1 -16 -16.7 03/04/2005 03:10:00 13 1.5 17.2 9.1 12.6 1.4 16.1 9.1 0.4 0 0.4 0.4 33 7 29 305 32 0 32 0 -16.5 0.1 -16 -16.6 03/04/2005 03:20:00 14.4 1.2 16.8 10.3 14.2 1.2 17.2 10.3 0.4 0 0.4 0.4 34 5 38 305 32 0 32 0 -16.5 0.1 -16 -16.6 03/04/2005 03:30:00 13.3 1.2 16.4 9.9 13 1.2 16.1 9.9 0.4 0 0.4 0.4 35 6 46 305 32 0 32 0 -16.5 0.1 -16 -16.6 03/04/2005 03:40:00 12.8 1.6 16.4 9.5 12.5 1.5 16.1 9.1 0.4 0 0.4 0.4 36 6 37 305 32 0 32 0 -16.4 0.1 -16 -16.6 03/04/2005 03:50:00 14.1 1.3 17.9 11.1 13.9 1.3 17.2 11.1 0.4 0 0.4 0.4 39 6 39 305 32 0 32 0 -16.5 0.1 -16 -16.6 03/04/2005 04:00:00 14 1.4 18.3 10.7 13.8 1.5 18.3 10.7 0.4 0 0.4 0.4 39 5 40 305 32 0 32 0 -16.4 0.1 -16 -16.6 03/04/2005 04:10:00 13.7 1.7 17.6 9.1 13.4 1.7 19.1 9.1 0.4 0 0.4 0.4 36 6 24 305 32 0 32 0 -16.4 0 -16 -16.6 03/04/2005 04:20:00 12.5 1.5 16.8 9.1 12.2 1.5 16.4 8.8 0.4 0 0.4 0.4 37 6 33 305 32 0 32 0 -16.4 0 -16 -16.6 03/04/2005 04:30:00 13 1.6 17.2 9.5 12.7 1.5 16.8 9.5 0.4 0 0.4 0.4 38 5 33 305 33 0 33 0 -16.4 0 -16 -16.6 03/04/2005 04:40:00 12.9 1.3 16.4 9.9 12.7 1.3 16.4 9.5 0.4 0 0.4 0.4 41 6 52 305 33 0 33 0 -16.3 0.1 -15.8 -16.6 03/04/2005 04:50:00 14.1 1.4 17.9 10.3 13.9 1.4 17.6 10.7 0.4 0 0.4 0.4 40 6 45 305 33 0 33 0 -16.3 0 -15.8 -16.6 03/04/2005 05:00:00 14.3 1.4 18.7 10.7 14 1.3 17.9 10.7 0.4 0 0.4 0.4 39 5 37 305 33 0 33 0 -16.3 0.1 -15.8 -16.4 03/04/2005 05:10:00 14.6 1.4 18.3 10.3 14.4 1.4 17.9 11.1 0.4 0 0.4 0.4 41 5 51 305 33 0 33 0 -16.2 0.1 -15.8 -16.4 03/04/2005 05:20:00 15.3 1.1 18.7 12.6 15.1 1.2 18.3 12.2 0.4 0 0.4 0.4 39 5 39 305 33 0 33 0 -16.3 0.1 -15.8 -16.4 03/04/2005 05:30:00 16.1 1.2 19.5 13.3 15.9 1.2 19.5 13.3 0.4 0 0.4 0.4 38 5 35 305 33 0 33 0 -16.3 0.1 -15.8 -16.6 03/04/2005 05:40:00 16 1.3 18.7 13 15.8 1.4 18.7 12.6 0.4 0 0.4 0.4 37 5 30 305 33 0 33 0 -16.2 0.1 -15.8 -16.4 03/04/2005 05:50:00 14.8 1.3 18.3 11.8 14.5 1.3 18.7 11.5 0.4 0 0.4 0.4 39 5 38 305 33 0 33 0 -16.2 0.2 -15.6 -16.4 03/04/2005 06:00:00 15.6 1.2 19.1 12.6 15.4 1.3 18.7 12.6 0.4 0 0.4 0.4 40 5 40 305 33 0 33 0 -16.1 0.1 -15.6 -16.4 03/04/2005 06:10:00 15.2 1.3 18.3 12.2 14.9 1.3 18.7 11.5 0.4 0 0.4 0.4 40 5 44 305 34 0 34 0 -16 0.1 -15.6 -16.4 03/04/2005 06:20:00 14.1 1.1 16.8 11.8 14 1.1 16.8 11.1 0.4 0 0.4 0.4 39 5 43 305 34 0 34 0 -15.9 0.1 -15.6 -16 03/04/2005 06:30:00 14.1 1.2 18.3 11.5 13.8 1.1 16.8 11.1 0.4 0 0.4 0.4 38 5 37 305 34 0 34 0 -15.9 0.1 -15.6 -16 03/04/2005 06:40:00 15.2 1.3 17.9 11.8 14.9 1.4 18.3 11.5 0.4 0 0.4 0.4 37 5 26 305 34 0 34 0 -15.8 0.1 -15.4 -16 03/04/2005 06:50:00 14.7 1.5 17.9 10.7 14.3 1.5 17.9 10.3 0.4 0 0.4 0.4 37 5 41 305 34 0 34 0 -15.8 0.1 -15.2 -16 03/04/2005 07:00:00 15.3 1.7 19.5 11.1 15.1 1.7 18.7 10.3 0.4 0 0.4 0.4 36 5 35 305 34 0 34 0 -15.8 0.1 -15.2 -16 03/04/2005 07:10:00 15.1 1.4 17.9 11.8 14.7 1.3 17.9 11.5 0.4 0 0.4 0.4 36 5 32 305 35 0 35 0 -15.7 0.2 -15.2 -15.8 03/04/2005 07:20:00 14.9 1.4 18.7 11.5 14.6 1.5 18.3 10.3 0.4 0 0.4 0.4 35 6 33 305 35 0 35 0 -15.7 0.2 -15.2 -15.8 03/04/2005 07:30:00 15 1.5 19.1 11.5 14.8 1.5 18.7 11.5 0.4 0 0.4 0.4 31 5 25 305 35 0 35 0 -15.8 0.1 -15.2 -16 03/04/2005 07:40:00 14.8 1.3 17.9 11.8 14.4 1.2 17.6 11.8 0.4 0 0.4 0.4 31 5 34 305 35 0 35 0 -15.8 0.1 -15.4 -16 03/04/2005 07:50:00 14.5 1.4 17.6 10.7 14.1 1.4 17.2 11.1 0.4 0 0.4 0.4 31 5 25 305 35 0 35 0 -15.8 0.1 -15.4 -16 03/04/2005 08:00:00 14.4 1.5 17.6 11.5 14.1 1.5 17.2 10.3 0.4 0 0.4 0.4 32 5 38 305 35 0 35 0 -15.9 0.1 -15.4 -16 03/04/2005 08:10:00 14.2 1.3 17.9 11.1 14 1.5 17.6 10.7 0.4 0 0.4 0.4 33 5 37 305 35 0 35 0 -16 0.1 -15.6 -16.2 03/04/2005 08:20:00 14.2 1.5 17.6 11.1 13.9 1.5 17.6 10.7 0.4 0 0.4 0.4 34 5 41 305 34 0 34 0 -16.1 0.1 -15.6 -16.2 03/04/2005 08:30:00 13.9 1.5 17.2 10.3 13.7 1.4 17.6 10.3 0.4 0 0.4 0.4 32 5 31 305 34 0 34 0 -16.1 0 -15.8 -16.4 03/04/2005 08:40:00 13.8 1.5 17.6 10.3 13.5 1.4 16.8 10.3 0.4 0 0.4 0.4 30 5 38 305 34 0 34 0 -16.3 0.1 -15.8 -16.4 03/04/2005 08:50:00 13.1 1.3 16.4 10.3 12.9 1.2 16.4 10.3 0.4 0 0.4 0.4 32 5 27 305 34 0 34 0 -16.3 0 -15.8 -16.6 03/04/2005 09:00:00 12.6 1.1 15.3 9.9 12.4 1.1 14.9 9.1 0.4 0 0.4 0.4 32 5 40 305 33 0 33 0 -16.3 0.1 -15.8 -16.6 03/04/2005 09:10:00 13.4 1.2 16.4 9.5 13.2 1.2 16.1 9.9 0.4 0 0.4 0.4 30 5 34 305 33 0 33 0 -16.3 0.1 -15.8 -16.6 03/04/2005 09:20:00 13.2 1.2 16.4 9.9 13 1.1 16.1 9.5 0.4 0 0.4 0.4 30 5 27 305 33 0 33 0 -16.3 0.1 -15.8 -16.6 03/04/2005 09:30:00 13.4 1.3 16.8 9.1 13 1.4 16.1 9.5 0.4 0 0.4 0.4 32 6 36 305 33 0 33 0 -16.3 0.1 -15.8 -16.6 03/04/2005 09:40:00 12.9 1.3 16.4 9.9 12.6 1.3 15.3 9.1 0.4 0 0.4 0.4 32 6 33 305 33 0 33 0 -16.2 0.1 -15.8 -16.4 03/04/2005 09:50:00 12.7 1.2 16.1 9.9 12.4 1.3 16.8 9.5 0.4 0 0.4 0.4 33 5 40 305 33 0 33 0 -16.2 0.1 -15.8 -16.4 03/04/2005 10:00:00 12.7 1.3 16.1 8.8 12.4 1.3 15.6 8.4 0.4 0 0.4 0.4 30 5 27 305 33 0 33 0 -16.2 0.1 -15.8 -16.4 03/04/2005 10:10:00 11.4 1.1 16.1 8.8 11.1 1.2 15.3 8.4 0.4 0 0.4 0.4 32 5 34 305 34 0 33 0 -16.3 0.1 -15.8 -16.4 03/04/2005 10:20:00 12.4 1.1 15.3 9.1 12.2 1.3 15.3 8.8 0.4 0 0.4 0.4 32 5 32 305 34 0 34 0 -16.2 0.1 -15.8 -16.4 03/04/2005 10:30:00 13.1 1.2 16.4 10.3 12.9 1.2 16.4 9.9 0.4 0 0.4 0.4 33 5 34 305 34 0 34 0 -16.1 0 -15.6 -16.2 03/04/2005 10:40:00 13.5 1.3 16.4 10.7 13.2 1.2 16.1 10.3 0.4 0 0.4 0.4 31 5 32 305 34 0 34 0 -16 0 -15.6 -16.2 03/04/2005 10:50:00 12.8 1.2 16.1 9.5 12.5 1.2 16.1 9.5 0.4 0 0.4 0.4 29 5 32 305 35 0 35 0 -15.8 0 -15.4 -16.2 03/04/2005 11:00:00 14 1.2 17.2 10.7 13.6 1.3 16.4 9.9 0.4 0 0.4 0.4 29 5 21 305 36 0 36 0 -15.8 0.1 -15.2 -16 03/04/2005 11:10:00 13.5 1.1 16.8 10.7 13.3 1.1 16.1 10.3 0.4 0 0.4 0.4 29 5 27 305 36 0 36 0 -15.7 0.2 -15.2 -15.8 03/04/2005 11:20:00 13.4 1.4 16.8 10.3 13.2 1.3 16.4 10.3 0.4 0 0.4 0.4 28 5 33 305 37 0 36 0 -15.7 0.2 -15.2 -15.8 03/04/2005 11:30:00 14 1.4 16.8 10.7 13.7 1.5 17.2 10.3 0.4 0 0.4 0.4 28 5 26 305 38 0 38 0 -15.7 0.2 -15 -15.8 03/04/2005 11:40:00 13.4 1.3 16.8 9.9 13.1 1.3 16.4 9.1 0.4 0 0.4 0.4 27 5 25 305 38 0 38 0 -15.7 0.2 -15.2 -15.8 03/04/2005 11:50:00 13.5 1.1 16.1 10.3 13.2 1.1 15.6 10.3 0.4 0 0.4 0.4 27 5 25 305 39 0 39 0 -15.8 0.1 -15.2 -15.8 03/04/2005 12:00:00 13.6 1.3 16.4 9.9 13.4 1.3 16.4 9.1 0.4 0 0.4 0.4 26 5 21 305 39 0 39 0 -15.8 0.1 -15.2 -16 03/04/2005 12:10:00 14.1 1.1 16.4 10.3 13.8 1.1 16.8 10.3 0.4 0 0.4 0.4 28 5 27 305 39 0 39 0 -15.7 0.2 -15.2 -16 03/04/2005 12:20:00 13.7 1.3 16.8 10.3 13.3 1.3 16.4 10.3 0.4 0 0.4 0.4 28 5 32 305 39 0 39 0 -15.8 0.1 -15.2 -16 03/04/2005 12:30:00 13.3 1.1 15.6 9.9 12.9 1.2 15.6 9.5 0.4 0 0.4 0.4 26 5 25 305 40 0 39 0 -15.8 0.1 -15 -16 03/04/2005 12:40:00 13.6 1.1 16.8 10.7 13.3 1.1 16.4 10.3 0.4 0 0.4 0.4 28 5 27 305 40 0 40 0 -15.6 0.2 -15 -15.8 03/04/2005 12:50:00 13.1 1.5 16.1 9.5 12.8 1.5 16.1 8.8 0.4 0 0.4 0.4 28 5 30 305 41 0 41 0 -15.5 0.1 -15 -15.6 03/04/2005 13:00:00 12.4 1.7 15.6 7.6 12 1.7 15.6 7.6 0.4 0 0.4 0.4 28 6 25 305 43 0 42 0 -15.5 0.1 -14.8 -15.6 03/04/2005 13:10:00 11.8 1.2 14.9 9.1 11.4 1.2 14.5 8.4 0.4 0 0.4 0.4 29 6 29 305 44 0 43 0 -15.4 0.1 -14.8 -15.6 03/04/2005 13:20:00 11 1 13.3 8.4 10.8 1 13.3 8 0.4 0 0.4 0.4 26 6 23 305 45 0 45 0 -15.3 0.1 -14.6 -15.6 03/04/2005 13:30:00 10.7 1.3 14.5 7.6 10.3 1.3 14.1 7.6 0.4 0 0.4 0.4 29 6 37 305 45 0 45 0 -15.3 0.1 -14.6 -15.6 03/04/2005 13:40:00 11 1.3 14.1 8 10.8 1.3 13.3 7.6 0.4 0 0.4 0.4 27 7 19 305 46 0 46 0 -15.2 0.1 -14.6 -15.6 03/04/2005 13:50:00 10.2 1.3 13.3 7.2 9.9 1.3 13.3 6.8 0.4 0 0.4 0.4 31 8 33 305 46 0 46 0 -15.1 0.1 -14.6 -15.6 03/04/2005 14:00:00 10.4 1.5 14.1 7.2 10.2 1.5 14.5 7.2 0.4 0 0.4 0.4 27 6 30 305 47 0 47 0 -15.3 0.1 -14.6 -15.6 03/04/2005 14:10:00 10.6 1.1 13 7.6 10.5 1.1 13.7 7.6 0.4 0 0.4 0.4 28 7 15 305 48 0 48 0 -15.2 0.1 -14.6 -15.6 03/04/2005 14:20:00 11.4 1.3 13.7 7.6 11.1 1.3 13.7 7.6 0.4 0 0.4 0.4 29 6 20 305 49 0 48 0 -15.5 0.1 -15 -15.8 03/04/2005 14:30:00 11.1 1.2 13.7 8.4 10.8 1.1 14.1 8.4 0.4 0 0.4 0.4 30 6 33 305 48 0 48 0 -15.7 0.1 -15 -15.8 03/04/2005 14:40:00 10.7 1.2 14.5 6.8 10.5 1.2 14.5 7.2 0.4 0 0.4 0.4 25 6 18 305 47 0 47 0 -15.7 0.1 -15 -15.8 03/04/2005 14:50:00 11.3 1.3 13.7 8 11 1.5 13.7 7.6 0.4 0 0.4 0.4 28 6 31 305 47 0 47 0 -15.7 0.2 -15 -15.8 03/04/2005 15:00:00 11.1 1.6 14.5 8 10.9 1.6 14.9 6.8 0.4 0 0.4 0.4 30 6 30 305 47 0 47 0 -15.6 0.1 -15 -15.8 03/04/2005 15:10:00 9.8 1.1 13.3 7.6 9.6 1 13 7.2 0.4 0 0.4 0.4 32 6 35 305 47 0 47 0 -15.5 0.2 -15 -15.8 03/04/2005 15:20:00 9.9 1 12.6 6.8 9.6 1 12.2 7.2 0.4 0 0.4 0.4 30 7 29 305 47 0 47 0 -15.5 0.2 -15 -15.8 03/04/2005 15:30:00 11.8 1.1 14.9 8.8 11.4 1.1 14.5 8.4 0.4 0 0.4 0.4 26 6 30 305 49 0 48 0 -15.7 0.1 -15 -15.8 03/04/2005 15:40:00 12.2 1.2 15.3 8.8 11.9 1.2 15.3 8 0.4 0 0.4 0.4 28 7 27 305 49 0 49 0 -15.7 0.2 -15 -16 03/04/2005 15:50:00 11.7 1.2 14.5 8.4 11.4 1.2 14.5 7.6 0.4 0 0.4 0.4 28 6 25 305 49 0 49 0 -15.8 0.1 -15.2 -16 03/04/2005 16:00:00 11.3 1.2 14.5 8.4 11 1.2 14.5 8 0.4 0 0.4 0.4 29 6 26 305 50 0 50 0 -15.7 0.2 -15.2 -16 03/04/2005 16:10:00 11.9 1.4 14.5 7.6 11.5 1.4 14.5 7.6 0.4 0 0.4 0.4 27 5 32 305 51 1 51 0 -15.7 0.1 -15.2 -16 03/04/2005 16:20:00 11.7 1.1 13.7 8 11.5 1.1 14.1 8.4 0.4 0 0.4 0.4 28 5 27 305 52 0 52 0 -15.8 0.1 -15.2 -16 03/04/2005 16:30:00 10.3 1.1 13.3 7.6 10.1 1.1 13 7.6 0.4 0 0.4 0.4 29 6 36 305 52 0 52 0 -15.8 0.1 -15.2 -16 03/04/2005 16:40:00 11.2 1 13.7 8.8 11 1 13.3 8 0.4 0 0.4 0.4 28 5 34 305 54 1 53 0 -15.7 0.2 -15.2 -15.8 03/04/2005 16:50:00 11.3 1.2 13.7 8 11 1.3 14.1 8 0.4 0 0.4 0.4 29 5 26 305 55 0 55 0 -15.8 0.1 -15.2 -16 03/04/2005 17:00:00 11.5 0.9 13.3 9.1 11.2 1 13.3 8.4 0.4 0 0.4 0.4 28 5 24 305 55 0 55 0 -15.8 0.1 -15.2 -16 03/04/2005 17:10:00 11.3 1.2 13.7 8 11.1 1.2 13.7 8 0.4 0 0.4 0.4 28 5 28 305 54 0 54 0 -15.8 0 -15.4 -16 03/04/2005 17:20:00 10.9 1 13.3 8.4 10.7 1.1 13.7 8.4 0.4 0 0.4 0.4 27 5 22 305 53 0 54 0 -15.9 0.1 -15.4 -16 03/04/2005 17:30:00 11.1 1 13.7 8.4 10.9 1.1 13.7 8 0.4 0 0.4 0.4 30 5 34 305 53 0 53 0 -15.9 0.1 -15.2 -16.2 03/04/2005 17:40:00 10.9 1.3 14.1 8.4 10.6 1.3 13.7 8 0.4 0 0.4 0.4 29 6 32 305 52 0 52 0 -15.8 0.1 -15.2 -16 03/04/2005 17:50:00 9.9 1 13 7.6 9.8 1.1 13 7.6 0.4 0 0.4 0.4 28 6 35 305 53 1 53 0 -15.8 0.1 -15.2 -16 03/04/2005 18:00:00 10.2 0.9 12.6 8 10 0.9 12.2 7.6 0.4 0 0.4 0.4 28 5 38 305 54 0 54 0 -15.8 0.1 -15.2 -16 03/04/2005 18:10:00 10.7 1 13.3 8.4 10.5 1 13 8.4 0.4 0 0.4 0.4 26 5 29 305 55 0 54 0 -15.8 0 -15.4 -16 03/04/2005 18:20:00 11.3 1 14.5 8.8 11.1 1 14.1 8.4 0.4 0 0.4 0.4 28 5 17 305 54 1 53 0 -15.9 0.1 -15.6 -16.2 03/04/2005 18:30:00 11.4 1.3 14.1 8.4 11.1 1.3 13.7 8.4 0.4 0 0.4 0.4 28 5 27 305 52 1 53 0 -16 0.1 -15.6 -16.4 03/04/2005 18:40:00 11 1 13.3 8.8 10.6 1 13.7 8.4 0.4 0 0.4 0.4 29 5 28 305 49 1 48 0 -16.1 0.1 -15.6 -16.2 03/04/2005 18:50:00 10.6 1.1 13.3 7.6 10.3 1.2 13.3 7.6 0.4 0 0.4 0.4 32 6 33 305 47 0 48 0 -16.1 0.1 -15.6 -16.4 03/04/2005 19:00:00 10.1 1.2 13.3 7.6 9.9 1.2 13.3 7.2 0.4 0 0.4 0.4 32 5 32 305 46 0 46 0 -16.3 0.1 -15.8 -16.6 03/04/2005 19:10:00 9.8 1.2 12.6 7.2 9.5 1.1 13 6.8 0.4 0 0.4 0.4 28 6 28 305 44 1 43 0 -16.3 0 -15.8 -16.6 03/04/2005 19:20:00 9.6 1.3 12.6 6.1 9.4 1.3 12.6 6.5 0.4 0 0.4 0.4 29 6 34 305 41 1 40 0 -16.5 0.1 -16 -16.7 03/04/2005 19:30:00 10.4 1.1 13.3 8 10.1 1.1 13.3 7.6 0.4 0 0.4 0.4 32 6 27 305 38 1 39 0 -16.7 0.2 -16 -16.9 03/04/2005 19:40:00 10.7 1.3 14.1 7.2 10.5 1.2 13.7 7.6 0.4 0 0.4 0.4 30 6 21 305 35 1 35 0 -16.7 0.2 -16.2 -16.9 03/04/2005 19:50:00 10.4 1.3 13.7 7.6 10.2 1.3 13.7 7.6 0.4 0 0.4 0.4 30 6 31 305 34 0 33 0 -16.7 0.1 -16.2 -16.9 03/04/2005 20:00:00 11.1 1.1 13.7 8 10.7 1.1 13.3 8 0.4 0 0.4 0.4 35 5 29 305 32 0 32 0 -16.7 0.1 -16.4 -16.9 03/04/2005 20:10:00 11.2 1.1 13.7 8.4 10.8 1.1 13.7 7.6 0.4 0 0.4 0.4 33 5 29 305 32 0 32 0 -16.7 0.1 -16.2 -16.9 03/04/2005 20:20:00 10.7 1 13.7 8.4 10.4 1 13.3 8 0.4 0 0.4 0.4 33 6 30 305 31 0 31 0 -16.7 0.1 -16.4 -16.9 03/04/2005 20:30:00 10.4 1.2 13.3 7.6 10.1 1.3 13.3 7.6 0.4 0 0.4 0.4 35 6 34 305 31 0 31 0 -16.8 0.1 -16.4 -16.9 03/04/2005 20:40:00 9.6 0.9 11.8 7.2 9.2 1 11.5 6.8 0.4 0 0.4 0.4 33 5 38 305 31 0 31 0 -16.9 0 -16.4 -16.9 03/04/2005 20:50:00 9.5 0.9 11.8 6.8 9.1 0.9 11.8 6.8 0.4 0 0.4 0.4 33 5 15 305 30 0 30 0 -16.9 0 -16.4 -16.9 03/04/2005 21:00:00 9.2 1.1 11.8 6.8 8.8 1 11.1 6.5 0.4 0 0.4 0.4 33 6 33 305 30 0 30 0 -16.9 0 -16.6 -16.9 03/04/2005 21:10:00 8.9 1.1 11.8 6.8 8.6 1 11.5 6.5 0.4 0 0.4 0.4 33 5 31 305 30 0 30 0 -16.9 0 -16.6 -16.9 03/04/2005 21:20:00 8.2 0.9 10.7 6.1 7.8 0.8 10.7 6.1 0.4 0 0.4 0.4 31 6 23 305 30 0 29 0 -16.9 0 -16.6 -16.9 03/04/2005 21:30:00 8.3 1 11.1 6.1 8 1 10.7 5.7 0.4 0 0.4 0.4 32 6 25 305 29 0 29 0 -16.9 0 -16.6 -17.1 03/04/2005 21:40:00 9.5 0.8 11.5 7.6 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 34 6 27 305 29 0 29 0 -16.9 0 -16.6 -17.1 03/04/2005 21:50:00 8.6 0.8 10.7 6.1 8.3 0.9 10.7 6.1 0.4 0 0.4 0.4 33 5 37 305 29 0 29 0 -17.1 0 -16.6 -17.3 03/04/2005 22:00:00 9.2 1 11.8 6.8 8.8 1.1 11.5 6.1 0.4 0 0.4 0.4 31 6 32 305 29 0 29 0 -17.2 0 -16.9 -17.3 03/04/2005 22:10:00 9 0.8 10.7 7.2 8.8 0.8 10.7 6.5 0.4 0 0.4 0.4 31 5 36 305 29 0 29 0 -17.2 0.1 -16.9 -17.3 03/04/2005 22:20:00 10 1 12.2 6.8 9.6 1 11.8 6.8 0.4 0 0.4 0.4 28 4 22 305 28 0 28 0 -17.3 0.1 -16.9 -17.5 03/04/2005 22:30:00 9.9 1 11.8 7.2 9.6 1 11.5 7.2 0.4 0 0.4 0.4 26 4 19 305 28 0 28 0 -17.3 0.1 -16.9 -17.5 03/04/2005 22:40:00 10.1 1 12.2 7.6 9.8 1 12.2 6.8 0.4 0 0.4 0.4 25 5 21 305 28 0 28 0 -17.4 0.1 -16.9 -17.5 03/04/2005 22:50:00 10 1 12.6 7.6 9.7 1 12.6 7.2 0.4 0 0.4 0.4 24 5 20 305 28 0 28 0 -17.5 0 -16.9 -17.5 03/04/2005 23:00:00 9.6 1 12.2 7.2 9.4 1 11.8 7.2 0.4 0 0.4 0.4 24 5 17 305 28 0 27 0 -17.5 0 -17.1 -17.5 03/04/2005 23:10:00 9.5 0.9 12.2 7.6 9.3 0.9 11.8 7.6 0.4 0 0.4 0.4 27 6 29 305 27 0 27 0 -17.5 0 -17.1 -17.5 03/04/2005 23:20:00 9.7 1 12.2 7.6 9.5 1 12.2 7.2 0.4 0 0.4 0.4 31 5 34 305 27 0 27 0 -17.5 0 -16.9 -17.5 03/04/2005 23:30:00 9.8 1 13 7.2 9.4 1 13 7.2 0.4 0 0.4 0.4 31 5 29 305 27 0 27 0 -17.5 0 -16.9 -17.5 03/04/2005 23:40:00 9.6 1.1 13 7.2 9.2 1.1 12.2 6.8 0.4 0 0.4 0.4 29 6 30 305 27 0 27 0 -17.5 0 -17.1 -17.7 03/04/2005 23:50:00 9.4 0.7 11.1 7.2 9.1 0.8 10.7 7.2 0.4 0 0.4 0.4 30 5 35 305 27 0 27 0 -17.5 0 -17.1 -17.7 03/05/2005 00:00:00 10.6 1 13.3 8 10.3 1 13.3 7.6 0.4 0 0.4 0.4 28 6 21 305 27 0 27 0 -17.5 0.1 -17.1 -17.7 03/05/2005 00:10:00 11 0.9 13 8.8 10.7 1 13.3 8.4 0.4 0 0.4 0.4 31 5 29 305 27 0 27 0 -17.6 0.1 -17.3 -17.9 03/05/2005 00:20:00 12.3 1 15.3 9.9 12 1 15.3 9.1 0.4 0 0.4 0.4 31 4 24 305 27 0 27 0 -17.7 0.1 -17.5 -17.9 03/05/2005 00:30:00 11.8 1 14.5 9.5 11.4 0.9 13.7 9.1 0.4 0 0.4 0.4 33 5 30 305 27 0 27 0 -17.7 0.1 -17.5 -18.1 03/05/2005 00:40:00 11.6 0.9 13.7 8.8 11.2 1 13.7 8.4 0.4 0 0.4 0.4 35 5 29 305 27 0 26 0 -17.7 0.1 -17.5 -18.1 03/05/2005 00:50:00 11.1 0.9 13.7 8.8 10.7 1 13 8.8 0.4 0 0.4 0.4 35 5 35 305 26 0 27 0 -17.8 0.1 -17.5 -18.1 03/05/2005 01:00:00 11.3 1 13.7 9.1 11 1 13.3 8.8 0.4 0 0.4 0.4 32 4 34 305 26 0 26 0 -17.8 0.1 -17.5 -18.1 03/05/2005 01:10:00 10.6 0.9 13.3 8.4 10.3 0.9 13 8.8 0.4 0 0.4 0.4 32 5 41 305 26 0 26 0 -17.9 0.1 -17.5 -18.1 03/05/2005 01:20:00 11.7 1 13.7 9.1 11.5 1.1 13.7 8.8 0.4 0 0.4 0.4 35 5 27 305 26 0 26 0 -17.8 0.1 -17.5 -18.1 03/05/2005 01:30:00 11.1 1 13.7 9.1 10.8 1 13.3 8.8 0.4 0 0.4 0.4 33 5 42 305 26 0 26 0 -17.8 0.1 -17.5 -18.1 03/05/2005 01:40:00 10.7 1 13.3 8.4 10.4 1 13.7 8 0.4 0 0.4 0.4 34 5 35 305 26 0 26 0 -17.8 0.1 -17.5 -18.1 03/05/2005 01:50:00 11.2 0.9 13.7 8.8 10.9 0.9 13.3 8.8 0.4 0 0.4 0.4 34 5 38 305 26 0 26 0 -17.7 0.1 -17.5 -18.1 03/05/2005 02:00:00 10.2 0.9 12.6 8 10 1 13.3 8 0.4 0 0.4 0.4 35 5 33 305 26 0 26 0 -17.8 0.1 -17.5 -18.1 03/05/2005 02:10:00 10.3 0.9 12.6 8.4 10 0.9 12.6 8.4 0.4 0 0.4 0.4 35 5 37 305 26 0 26 0 -17.9 0.1 -17.5 -18.1 03/05/2005 02:20:00 9.3 1 12.6 7.2 9 1 12.2 7.2 0.4 0 0.4 0.4 33 5 35 305 26 0 26 0 -17.9 0 -17.7 -18.1 03/05/2005 02:30:00 10.1 0.8 12.2 8.4 9.9 0.9 11.8 8 0.4 0 0.4 0.4 35 5 34 305 26 0 26 0 -18 0 -17.7 -18.1 03/05/2005 02:40:00 9.1 0.8 11.8 7.2 8.9 0.8 11.5 6.8 0.4 0 0.4 0.4 34 5 26 305 26 0 26 0 -18 0 -18.1 -18.2 03/05/2005 02:50:00 10.3 0.8 12.6 8 9.9 0.9 12.2 7.2 0.4 0 0.4 0.4 36 5 37 305 26 0 26 0 -18 0 -17.7 -18.1 03/05/2005 03:00:00 9.7 0.8 11.5 7.6 9.4 0.8 11.1 7.2 0.4 0 0.4 0.4 37 5 36 305 26 0 26 0 -17.9 0 -17.5 -18.1 03/05/2005 03:10:00 9.7 0.9 11.8 7.2 9.4 0.9 11.8 6.8 0.4 0 0.4 0.4 35 5 37 305 26 0 25 0 -18 0 -17.5 -18.1 03/05/2005 03:20:00 9.4 0.8 11.5 7.6 9.1 0.8 11.1 7.2 0.4 0 0.4 0.4 33 5 24 305 26 0 25 0 -17.9 0 -17.5 -18.1 03/05/2005 03:30:00 9.2 1.1 11.8 6.8 8.9 1.1 11.8 6.8 0.4 0 0.4 0.4 27 5 32 305 26 0 26 0 -17.9 0.1 -17.5 -18.1 03/05/2005 03:40:00 10.2 1 13 7.6 10 1 13 7.6 0.4 0 0.4 0.4 26 5 25 305 26 0 26 0 -17.9 0 -17.5 -18.1 03/05/2005 03:50:00 11 1.1 13.3 7.6 10.7 1.1 13 7.6 0.4 0 0.4 0.4 31 5 31 305 26 0 26 0 -17.8 0.1 -17.5 -18.1 03/05/2005 04:00:00 10.7 1.2 14.5 8 10.6 1.2 14.5 7.6 0.4 0 0.4 0.4 31 6 25 305 26 0 26 0 -17.9 0 -17.5 -18.1 03/05/2005 04:10:00 10.9 1 13.7 7.6 10.6 1 13 8 0.4 0 0.4 0.4 30 5 28 305 26 0 26 0 -18 0 -17.9 -18.1 03/05/2005 04:20:00 8.5 1 11.5 6.1 8.3 1 10.3 5.7 0.4 0 0.4 0.4 30 5 32 305 26 0 26 0 -18.1 0 -18.1 -18.2 03/05/2005 04:30:00 8.3 0.8 11.1 6.1 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 29 5 27 305 26 0 26 0 -18.1 0.1 -17.9 -18.4 03/05/2005 04:40:00 7.9 0.8 9.9 6.1 7.7 0.9 9.9 5.7 0.4 0 0.4 0.4 28 5 27 305 25 0 25 0 -18.3 0.1 -18.1 -18.4 03/05/2005 04:50:00 8.4 0.9 10.7 6.1 8.1 0.9 9.9 5.7 0.4 0 0.4 0.4 29 6 32 305 25 0 25 0 -18.5 0 -18.1 -18.6 03/05/2005 05:00:00 7.7 0.9 9.9 5.7 7.5 0.9 9.9 5.7 0.4 0 0.4 0.4 31 5 32 305 25 0 25 0 -18.5 0 -18.1 -18.6 03/05/2005 05:10:00 8.3 0.7 10.3 6.5 8.1 0.7 9.9 6.1 0.4 0 0.4 0.4 29 5 27 305 24 0 25 0 -18.5 0 -18.2 -18.6 03/05/2005 05:20:00 8.5 0.8 10.7 6.8 8.3 0.8 10.7 6.5 0.4 0 0.4 0.4 29 5 31 305 24 0 24 0 -18.6 0 -18.1 -18.8 03/05/2005 05:30:00 8.2 0.9 11.1 6.1 8 0.8 10.3 6.5 0.4 0 0.4 0.4 30 5 29 305 24 0 24 0 -18.6 0 -18.2 -18.8 03/05/2005 05:40:00 8.2 1 11.1 6.1 8.2 1 10.7 5.7 0.4 0 0.4 0.4 27 5 28 305 24 0 24 0 -18.6 0 -18.2 -18.6 03/05/2005 05:50:00 7.5 1 9.9 5.3 7.2 1 10.3 5.3 0.4 0 0.4 0.4 26 5 23 305 24 0 24 0 -18.7 0 -18.4 -19 03/05/2005 06:00:00 7.4 0.8 9.5 5.7 7.1 0.7 9.1 5.3 0.4 0 0.4 0.4 28 6 23 305 24 0 24 0 -18.8 0 -18.4 -19 03/05/2005 06:10:00 7.1 0.7 8.8 5.3 6.9 0.7 8.8 5.7 0.4 0 0.4 0.4 32 6 43 305 23 0 24 0 -18.8 0 -18.4 -19 03/05/2005 06:20:00 8.1 0.7 9.9 6.5 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 33 6 40 305 23 0 23 0 -18.7 0 -18.4 -19 03/05/2005 06:30:00 7.7 0.8 9.9 5.7 7.6 0.8 9.5 5.7 0.4 0 0.4 0.4 35 5 37 305 23 0 23 0 -18.8 0 -18.4 -19 03/05/2005 06:40:00 8.4 0.6 9.9 6.8 8.1 0.6 9.5 6.1 0.4 0 0.4 0.4 35 5 37 305 23 0 23 0 -18.8 0 -18.4 -19 03/05/2005 06:50:00 8.6 0.8 10.3 6.1 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 34 5 40 305 23 0 23 0 -18.8 0 -18.4 -19 03/05/2005 07:00:00 7.5 0.6 9.5 6.1 7.2 0.6 9.1 5.7 0.4 0 0.4 0.4 35 5 29 305 23 0 23 0 -18.9 0.1 -18.6 -19 03/05/2005 07:10:00 7 0.5 8.8 5.3 6.7 0.5 8.4 5.3 0.4 0 0.4 0.4 36 4 33 305 23 0 23 0 -19 0 -18.6 -19 03/05/2005 07:20:00 8.4 0.8 10.7 6.1 8.2 0.8 10.3 6.1 0.4 0 0.4 0.4 41 5 44 305 23 0 23 0 -18.8 0 -18.4 -19 03/05/2005 07:30:00 8.5 0.8 11.1 6.8 8.2 0.8 10.7 6.5 0.4 0 0.4 0.4 38 5 41 305 23 0 23 0 -18.8 0 -18.4 -19 03/05/2005 07:40:00 8.8 0.9 11.1 6.8 8.6 0.9 11.1 6.5 0.4 0 0.4 0.4 37 6 36 305 23 0 23 0 -18.8 0 -18.4 -19 03/05/2005 07:50:00 10.1 1 12.6 6.8 9.9 1 12.2 6.8 0.4 0 0.4 0.4 37 5 44 305 23 0 23 0 -18.8 0 -18.4 -19 03/05/2005 08:00:00 9.8 0.9 11.8 7.2 9.6 0.9 11.5 6.8 0.4 0 0.4 0.4 34 5 30 305 23 0 23 0 -19 0 -18.6 -19 03/05/2005 08:10:00 9.4 0.9 11.5 7.2 9.1 1 11.5 6.5 0.4 0 0.4 0.4 36 5 31 305 23 0 22 0 -19.1 0 -19 -19.2 03/05/2005 08:20:00 9.4 0.9 11.8 7.6 9.2 1 11.1 7.2 0.4 0 0.4 0.4 37 5 35 305 22 0 22 0 -19.1 0 -19 -19.3 03/05/2005 08:30:00 8.5 0.9 10.7 6.5 8.3 0.9 10.7 6.5 0.4 0 0.4 0.4 38 5 32 305 22 0 22 0 -19.2 0.1 -19 -19.5 03/05/2005 08:40:00 7.9 0.6 9.5 6.1 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 39 4 33 305 22 0 22 0 -19.3 0 -19 -19.5 03/05/2005 08:50:00 8 0.5 9.5 6.8 7.6 0.5 9.1 6.1 0.4 0 0.4 0.4 41 4 40 305 22 0 22 0 -19.4 0 -19 -19.5 03/05/2005 09:00:00 7.6 0.6 9.1 6.1 7.4 0.6 9.1 5.3 0.4 0 0.4 0.4 41 4 40 305 22 0 22 0 -19.4 0 -19 -19.5 03/05/2005 09:10:00 7.9 0.6 9.5 6.5 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 44 4 37 305 22 0 22 0 -19.5 0.1 -19.2 -19.5 03/05/2005 09:20:00 8.3 0.7 10.7 6.5 8.1 0.6 10.3 6.5 0.4 0 0.4 0.4 43 5 40 305 22 0 22 0 -19.4 0 -19 -19.5 03/05/2005 09:30:00 8.2 0.5 9.5 6.8 8 0.6 9.1 6.5 0.4 0 0.4 0.4 41 4 37 305 22 0 22 0 -19.4 0 -19 -19.5 03/05/2005 09:40:00 7.8 0.5 9.1 6.8 7.5 0.5 9.1 6.5 0.4 0 0.4 0.4 39 4 32 305 22 0 22 0 -19.4 0 -19.2 -19.5 03/05/2005 09:50:00 8.2 0.6 9.5 6.8 7.9 0.6 9.5 6.5 0.4 0 0.4 0.4 41 4 43 305 22 0 22 0 -19.4 0.1 -19 -19.5 03/05/2005 10:00:00 9.1 0.9 11.5 6.8 8.9 1 11.5 6.8 0.4 0 0.4 0.4 40 5 35 305 22 0 22 0 -19.4 0.1 -19 -19.5 03/05/2005 10:10:00 8.9 0.6 10.3 7.6 8.7 0.7 10.3 6.8 0.4 0 0.4 0.4 38 5 38 305 22 0 22 0 -19.4 0.1 -19 -19.5 03/05/2005 10:20:00 8.9 0.7 10.3 6.8 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 36 4 35 305 22 0 22 0 -19.4 0.1 -19.2 -19.5 03/05/2005 10:30:00 9.1 0.6 10.7 7.2 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 35 4 36 305 22 0 22 0 -19.4 0.1 -19.2 -19.5 03/05/2005 10:40:00 9.1 0.7 10.7 7.2 8.8 0.8 10.3 6.8 0.4 0 0.4 0.4 36 4 27 305 22 0 22 0 -19.4 0.1 -19 -19.5 03/05/2005 10:50:00 8.6 0.6 9.9 7.2 8.4 0.7 9.9 6.8 0.4 0 0.4 0.4 36 4 43 305 23 0 22 0 -19.3 0.1 -19 -19.5 03/05/2005 11:00:00 8.2 0.5 9.5 6.8 8 0.5 9.5 6.1 0.4 0 0.4 0.4 37 4 40 305 24 0 24 0 -19.3 0 -19 -19.5 03/05/2005 11:10:00 8.2 0.7 10.3 6.5 8 0.7 9.9 6.5 0.4 0 0.4 0.4 38 5 40 305 25 0 25 0 -19.2 0 -18.8 -19.3 03/05/2005 11:20:00 8.3 0.6 10.7 6.8 8.1 0.6 9.9 6.8 0.4 0 0.4 0.4 38 5 33 305 25 0 25 0 -19.1 0 -18.6 -19.2 03/05/2005 11:30:00 8.6 1 11.1 6.1 8.4 1 11.5 6.5 0.4 0 0.4 0.4 35 5 40 305 26 0 26 0 -19 0.1 -18.4 -19 03/05/2005 11:40:00 9 0.8 11.1 6.8 8.7 0.9 10.7 6.5 0.4 0 0.4 0.4 34 5 29 305 27 0 27 0 -18.7 0.1 -18.2 -19 03/05/2005 11:50:00 9.7 1 11.8 7.2 9.4 1 11.8 6.8 0.4 0 0.4 0.4 34 6 27 305 27 0 27 0 -18.6 0.1 -18.1 -18.8 03/05/2005 12:00:00 9.4 1.1 13 7.6 9.1 1.1 13 6.8 0.4 0 0.4 0.4 32 5 39 305 28 0 28 0 -18.6 0 -18.1 -18.8 03/05/2005 12:10:00 10 0.7 11.8 8 9.7 0.8 11.8 7.6 0.4 0 0.4 0.4 35 5 40 305 28 0 28 0 -18.6 0 -18.1 -18.8 03/05/2005 12:20:00 10.4 1 12.6 7.2 10.1 1 12.2 7.6 0.4 0 0.4 0.4 37 5 39 305 28 0 28 0 -18.6 0.1 -18.1 -18.8 03/05/2005 12:30:00 10 1 11.8 7.2 9.7 1 11.8 7.2 0.4 0 0.4 0.4 35 5 44 305 28 0 28 0 -18.6 0 -18.1 -18.8 03/05/2005 12:40:00 10.1 1.1 12.6 7.2 10 1.2 13 7.2 0.4 0 0.4 0.4 34 5 35 305 29 0 29 0 -18.6 0 -18.1 -18.6 03/05/2005 12:50:00 10.6 1 12.6 8 10.3 1.1 12.6 7.6 0.4 0 0.4 0.4 35 5 33 305 29 0 29 0 -18.5 0 -18.1 -18.6 03/05/2005 13:00:00 10.3 1.1 13.3 8 10.1 1.1 13.3 7.6 0.4 0 0.4 0.4 36 5 36 305 29 0 29 0 -18.3 0.1 -17.9 -18.4 03/05/2005 13:10:00 10 0.9 12.6 7.6 9.7 1 13 7.6 0.4 0 0.4 0.4 36 5 31 305 30 0 29 0 -18.2 0 -17.7 -18.4 03/05/2005 13:20:00 9.8 0.8 11.8 8 9.6 0.9 11.8 8 0.4 0 0.4 0.4 37 5 36 305 30 0 30 0 -18.1 0.1 -17.5 -18.4 03/05/2005 13:30:00 10.7 1 12.6 7.6 10.4 1 12.6 7.2 0.4 0 0.4 0.4 34 4 32 305 31 0 31 0 -18.1 0.1 -17.5 -18.2 03/05/2005 13:40:00 11.8 1.1 14.5 9.1 11.5 1.2 14.9 8.4 0.4 0 0.4 0.4 35 5 35 305 31 0 31 0 -18.1 0 -17.5 -18.2 03/05/2005 13:50:00 11.2 0.9 13 8.8 11.1 0.9 13.3 8.8 0.4 0 0.4 0.4 35 5 36 305 30 0 31 0 -18 0.1 -17.5 -18.1 03/05/2005 14:00:00 10.6 0.8 13 8 10.4 0.9 12.2 8.4 0.4 0 0.4 0.4 37 5 40 305 30 0 30 0 -17.9 0.1 -17.5 -18.1 03/05/2005 14:10:00 10 0.7 12.2 8.4 9.8 0.7 11.8 7.6 0.4 0 0.4 0.4 34 6 31 305 31 0 31 0 -17.8 0.1 -17.5 -18.1 03/05/2005 14:20:00 10.9 1.1 13.3 8.8 10.7 1.1 13.3 8.8 0.4 0 0.4 0.4 34 5 30 305 31 0 32 0 -17.8 0.1 -17.5 -18.1 03/05/2005 14:30:00 10.8 1.2 13.3 8 10.5 1.2 13 7.6 0.4 0 0.4 0.4 34 5 37 305 31 0 32 0 -17.8 0.1 -17.3 -18.1 03/05/2005 14:40:00 10.6 1.2 13.7 8 10.4 1.2 13.7 8 0.4 0 0.4 0.4 35 5 33 305 32 0 32 0 -17.9 0.1 -17.5 -18.1 03/05/2005 14:50:00 10.8 1 13.3 8.4 10.5 1 13 8 0.4 0 0.4 0.4 34 4 38 305 32 0 33 0 -17.7 0.1 -17.3 -18.1 03/05/2005 15:00:00 11.4 0.9 13.7 8.8 11.1 1 13.7 8 0.4 0 0.4 0.4 37 5 41 305 33 0 33 0 -17.8 0.1 -17.3 -18.1 03/05/2005 15:10:00 11.5 0.9 13.3 9.1 11.3 0.9 13.3 9.1 0.4 0 0.4 0.4 35 4 36 305 33 0 33 0 -17.7 0 -17.3 -17.9 03/05/2005 15:20:00 11.1 0.7 13 9.1 10.8 0.8 12.6 9.1 0.4 0 0.4 0.4 36 4 35 305 34 0 34 0 -17.5 0.1 -16.9 -17.9 03/05/2005 15:30:00 10.8 0.9 12.6 8.4 10.5 0.9 12.6 7.6 0.4 0 0.4 0.4 36 5 35 305 35 0 34 0 -17.4 0.1 -16.9 -17.5 03/05/2005 15:40:00 9.9 0.9 11.8 8 9.7 1 11.8 7.2 0.4 0 0.4 0.4 35 6 35 305 36 0 35 0 -17.3 0.1 -16.9 -17.5 03/05/2005 15:50:00 11.6 0.9 13 8.4 11.4 1 13 8.4 0.4 0 0.4 0.4 31 4 33 305 38 1 37 0 -17.5 0.1 -16.9 -17.7 03/05/2005 16:00:00 11.1 1 13.3 8.8 11 1 13.7 8.8 0.4 0 0.4 0.4 34 5 31 305 38 0 38 0 -17.5 0 -16.9 -17.5 03/05/2005 16:10:00 11.7 0.8 13.7 9.1 11.4 0.9 13.7 9.1 0.4 0 0.4 0.4 34 4 31 305 38 0 38 0 -17.5 0 -16.9 -17.7 03/05/2005 16:20:00 10.8 1 12.6 8.8 10.6 1 12.6 8.4 0.4 0 0.4 0.4 37 5 38 305 38 0 39 0 -17.5 0 -16.9 -17.5 03/05/2005 16:30:00 10.8 0.9 12.6 8.4 10.5 1 13 7.2 0.4 0 0.4 0.4 32 5 32 305 39 0 39 0 -17.4 0.1 -16.9 -17.5 03/05/2005 16:40:00 11 0.9 13 8.8 10.8 1 13 8 0.4 0 0.4 0.4 34 4 33 305 40 0 40 0 -17.4 0.1 -16.9 -17.5 03/05/2005 16:50:00 10.9 0.8 13 9.1 10.7 0.8 12.6 8.4 0.4 0 0.4 0.4 37 5 36 305 40 0 40 0 -17.4 0 -16.9 -17.5 03/05/2005 17:00:00 10.3 0.7 12.2 8.4 10 0.8 12.2 8 0.4 0 0.4 0.4 35 5 35 305 40 0 40 0 -17.5 0 -16.9 -17.7 03/05/2005 17:10:00 10.6 1.1 13.3 7.6 10.4 1.2 13.3 7.2 0.4 0 0.4 0.4 35 4 38 305 40 0 40 0 -17.5 0.1 -16.9 -17.7 03/05/2005 17:20:00 12 0.8 14.5 9.5 11.8 1 14.5 8.8 0.4 0 0.4 0.4 38 4 40 305 40 0 41 0 -17.5 0.1 -16.9 -17.7 03/05/2005 17:30:00 11.3 0.8 13 8.8 11.1 0.9 13.3 8.8 0.4 0 0.4 0.4 37 5 31 305 40 0 40 0 -17.5 0.1 -16.9 -17.7 03/05/2005 17:40:00 11 0.9 13.3 8.4 10.8 0.9 13.3 8.4 0.4 0 0.4 0.4 40 5 41 305 40 0 39 0 -17.6 0.1 -17.1 -17.9 03/05/2005 17:50:00 12.2 0.8 14.1 9.5 11.9 1 14.1 9.5 0.4 0 0.4 0.4 41 5 41 305 39 0 39 0 -17.8 0.1 -17.5 -18.1 03/05/2005 18:00:00 12 0.9 14.1 9.5 11.8 1 14.1 9.5 0.4 0 0.4 0.4 39 4 45 305 38 0 39 0 -17.9 0.1 -17.5 -18.1 03/05/2005 18:10:00 11 0.7 13 9.1 10.8 0.8 13 8.8 0.4 0 0.4 0.4 39 4 40 305 37 0 38 0 -17.9 0.1 -17.5 -18.1 03/05/2005 18:20:00 10.6 0.6 12.2 9.1 10.3 0.7 12.2 8.4 0.4 0 0.4 0.4 38 5 32 305 36 0 36 0 -17.9 0.1 -17.5 -18.1 03/05/2005 18:30:00 10.8 0.8 12.2 8.8 10.5 0.8 12.2 8.4 0.4 0 0.4 0.4 39 4 43 305 36 0 36 0 -18 0 -17.5 -18.1 03/05/2005 18:40:00 11.6 0.7 13.3 9.9 11.4 0.7 13 9.5 0.4 0 0.4 0.4 41 4 59 305 35 0 35 0 -18 0 -17.5 -18.2 03/05/2005 18:50:00 11.6 0.6 13.3 9.9 11.3 0.7 13.3 9.1 0.4 0 0.4 0.4 39 5 47 305 34 0 34 0 -18.1 0 -17.7 -18.1 03/05/2005 19:00:00 12.5 0.8 14.9 10.3 12.3 0.9 15.3 9.9 0.4 0 0.4 0.4 35 5 37 305 33 0 34 0 -18.1 0.1 -17.7 -18.4 03/05/2005 19:10:00 12.5 1 14.9 10.3 12.2 1 15.6 10.3 0.4 0 0.4 0.4 37 5 31 305 32 1 32 0 -18.2 0 -17.9 -18.4 03/05/2005 19:20:00 12.4 1 14.9 10.3 12.3 1 14.9 9.5 0.4 0 0.4 0.4 38 5 41 305 30 0 29 0 -18.3 0.1 -18.1 -18.4 03/05/2005 19:30:00 12.8 0.9 15.6 10.3 12.6 0.9 15.3 10.3 0.4 0 0.4 0.4 40 4 41 305 28 0 29 0 -18.4 0.1 -18.1 -18.4 03/05/2005 19:40:00 11.8 0.7 13.7 9.9 11.5 0.7 13.7 9.9 0.4 0 0.4 0.4 40 4 37 305 27 0 27 0 -18.5 0 -18.1 -18.6 03/05/2005 19:50:00 11.8 0.8 14.1 9.5 11.5 0.9 14.1 9.1 0.4 0 0.4 0.4 38 5 40 305 26 0 26 0 -18.6 0 -18.2 -18.8 03/05/2005 20:00:00 11.9 0.9 14.1 9.5 11.8 1 14.1 9.5 0.4 0 0.4 0.4 40 4 35 305 25 0 25 0 -18.6 0.1 -18.2 -18.8 03/05/2005 20:10:00 12 0.7 13.3 9.9 11.7 0.8 13.7 9.1 0.4 0 0.4 0.4 42 4 44 305 25 0 25 0 -18.7 0.1 -18.2 -19 03/05/2005 20:20:00 12.5 0.8 14.1 10.3 12.2 0.9 14.5 10.3 0.4 0 0.4 0.4 40 5 39 305 24 0 24 0 -18.7 0.1 -18.4 -19 03/05/2005 20:30:00 11.9 0.8 14.1 9.9 11.7 0.9 14.1 9.5 0.4 0 0.4 0.4 40 4 44 305 24 0 24 0 -18.8 0 -18.4 -19 03/05/2005 20:40:00 11.5 0.9 13.7 9.5 11.2 0.9 13.7 9.1 0.4 0 0.4 0.4 35 4 33 305 24 0 24 0 -18.8 0 -18.6 -19 03/05/2005 20:50:00 12.8 0.9 15.6 10.7 12.4 1 14.9 10.3 0.4 0 0.4 0.4 40 4 37 305 24 0 24 0 -18.9 0 -18.4 -19 03/05/2005 21:00:00 13.1 0.7 14.9 10.7 12.9 0.8 14.9 9.9 0.4 0 0.4 0.4 41 4 42 305 23 0 24 0 -18.9 0.1 -18.4 -19 03/05/2005 21:10:00 13.6 0.8 15.6 11.5 13.4 0.8 15.3 11.5 0.4 0 0.4 0.4 40 4 44 305 23 0 23 0 -18.9 0 -18.4 -19 03/05/2005 21:20:00 13.4 0.9 16.1 11.1 13.2 1 16.4 11.1 0.4 0 0.4 0.4 40 4 36 305 23 0 23 0 -19 0.1 -18.4 -19 03/05/2005 21:30:00 14 1.5 17.6 10.7 13.7 1.6 17.2 10.7 0.4 0 0.4 0.4 37 5 35 305 23 0 23 0 -18.9 0.1 -18.4 -19 03/05/2005 21:40:00 15 1 17.2 12.6 14.8 1 17.6 12.2 0.4 0 0.4 0.4 40 5 38 305 23 0 23 0 -19 0 -18.6 -19.2 03/05/2005 21:50:00 15.5 1 17.9 12.2 15.3 1.1 18.3 12.6 0.4 0 0.4 0.4 41 4 41 305 23 0 23 0 -19.1 0 -18.8 -19.2 03/05/2005 22:00:00 14.8 1.4 18.3 11.8 14.5 1.4 18.3 10.7 0.4 0 0.4 0.4 40 5 38 305 23 0 22 0 -19.1 0 -18.8 -19.2 03/05/2005 22:10:00 16.2 1.3 18.7 12.2 15.8 1.3 18.7 11.8 0.4 0 0.4 0.4 39 5 42 305 22 0 22 0 -19 0 -18.6 -19.2 03/05/2005 22:20:00 15.9 1 18.7 13.3 15.7 1.1 18.3 13 0.4 0 0.4 0.4 38 4 39 305 22 0 22 0 -19 0.1 -18.6 -19 03/05/2005 22:30:00 15.1 1 17.6 11.8 14.8 1.1 17.6 11.8 0.4 0 0.4 0.4 41 4 48 305 23 0 23 0 -19.1 0 -18.6 -19.2 03/05/2005 22:40:00 15.1 1 17.6 12.6 14.9 1 17.2 12.2 0.4 0 0.4 0.4 45 4 45 305 23 0 22 0 -19.2 0 -19 -19.3 03/05/2005 22:50:00 14.9 0.8 16.8 13 14.8 0.8 16.8 12.6 0.4 0 0.4 0.4 44 3 44 305 22 0 22 0 -19.2 0 -19 -19.5 03/05/2005 23:00:00 14.7 1.3 17.9 11.8 14.3 1.4 17.9 11.5 0.4 0 0.4 0.4 43 4 40 305 22 0 22 0 -19.2 0.1 -19 -19.5 03/05/2005 23:10:00 15.4 1 17.6 13 15.2 1.1 17.6 12.6 0.4 0 0.4 0.4 43 5 41 305 22 0 22 0 -19.5 0.1 -19 -19.5 03/05/2005 23:20:00 14 1.1 16.8 10.7 13.8 1.1 16.8 10.7 0.4 0 0.4 0.4 44 4 42 305 22 0 22 0 -19.6 0 -19.2 -19.5 03/05/2005 23:30:00 15 1.2 17.6 11.5 14.7 1.3 17.2 11.8 0.4 0 0.4 0.4 41 4 40 305 22 0 22 0 -19.6 0 -19.3 -19.7 03/05/2005 23:40:00 14.4 0.9 16.4 12.2 14.2 1 16.8 11.8 0.4 0 0.4 0.4 43 4 36 305 21 0 21 0 -19.6 0 -19.3 -19.7 03/05/2005 23:50:00 14.3 1 16.4 11.8 14 1 16.8 10.7 0.4 0 0.4 0.4 44 5 36 305 21 0 21 0 -19.7 0 -19.5 -19.9 03/06/2005 00:00:00 14 1 17.2 11.8 13.8 1.1 17.2 11.1 0.4 0 0.4 0.4 47 3 47 305 21 0 21 0 -20 0.1 -19.5 -20.1 03/06/2005 00:10:00 15 0.9 17.2 13 14.9 1 17.6 12.2 0.4 0 0.4 0.4 46 4 46 305 21 0 21 0 -20 0.1 -19.7 -20.1 03/06/2005 00:20:00 14.6 1 16.8 12.2 14.3 1 16.8 11.8 0.4 0 0.4 0.4 47 4 57 305 21 0 21 0 -20 0.1 -19.7 -20.1 03/06/2005 00:30:00 12.9 0.9 16.4 11.1 12.6 0.9 15.3 10.7 0.4 0 0.4 0.4 47 5 51 305 21 0 20 0 -20.2 0 -19.9 -20.2 03/06/2005 00:40:00 13.6 1.2 17.2 11.1 13.4 1.2 16.8 10.7 0.4 0 0.4 0.4 47 6 50 305 20 0 20 0 -20 0 -19.7 -20.1 03/06/2005 00:50:00 13.5 0.9 16.1 10.7 13.3 1 15.6 11.1 0.4 0 0.4 0.4 50 4 50 305 20 0 20 0 -20.2 0 -19.9 -20.1 03/06/2005 01:00:00 13.2 1 15.3 10.7 12.9 1 16.1 10.7 0.4 0 0.4 0.4 47 6 56 305 20 0 20 0 -20.1 0 -19.9 -20.2 03/06/2005 01:10:00 14 1 16.4 11.5 13.9 1.1 16.4 10.7 0.4 0 0.4 0.4 51 5 45 305 20 0 20 0 -20.2 0 -19.7 -20.2 03/06/2005 01:20:00 13.3 1 16.4 11.1 13 1.1 16.1 10.3 0.4 0 0.4 0.4 51 5 46 305 20 0 20 0 -20.2 0 -19.9 -20.4 03/06/2005 01:30:00 13.7 1 16.1 11.5 13.4 1.1 16.1 11.1 0.4 0 0.4 0.4 49 5 54 305 20 0 20 0 -20.2 0 -20.1 -20.2 03/06/2005 01:40:00 14 1 16.1 11.5 13.8 1 16.4 11.1 0.4 0 0.4 0.4 41 5 36 305 20 0 20 0 -20.2 0 -19.9 -20.1 03/06/2005 01:50:00 12.9 1.1 15.6 9.5 12.7 1.2 15.6 9.1 0.4 0 0.4 0.4 45 5 40 305 20 0 20 0 -20.2 0 -20.1 -20.2 03/06/2005 02:00:00 13.9 1.3 16.8 10.7 13.7 1.5 17.2 10.3 0.4 0 0.4 0.4 43 5 40 305 20 0 20 0 -20.2 0 -19.9 -20.2 03/06/2005 02:10:00 14.5 1.1 17.2 11.5 14.4 1.1 17.2 11.5 0.4 0 0.4 0.4 49 4 44 305 20 0 20 0 -20.2 0 -19.9 -20.4 03/06/2005 02:20:00 14.5 1.1 17.2 12.2 14.3 1.2 17.2 11.5 0.4 0 0.4 0.4 45 4 42 305 20 0 20 0 -20.2 0 -20.1 -20.4 03/06/2005 02:30:00 15.1 0.7 17.2 13 15 0.8 17.6 12.6 0.4 0 0.4 0.4 45 3 50 305 20 0 20 0 -20.3 0 -20.1 -20.4 03/06/2005 02:40:00 14.2 0.8 16.1 12.2 14 0.9 16.4 11.5 0.4 0 0.4 0.4 47 4 45 305 20 0 20 0 -20.3 0 -20.1 -20.4 03/06/2005 02:50:00 13.9 1 16.1 11.5 13.7 1 16.1 10.7 0.4 0 0.4 0.4 45 5 41 305 20 0 20 0 -20.3 0 -20.1 -20.6 03/06/2005 03:00:00 14.3 1 16.8 11.5 14.1 1.1 17.2 11.1 0.4 0 0.4 0.4 41 5 43 305 20 0 20 0 -20.2 0 -20.1 -20.4 03/06/2005 03:10:00 13.5 0.9 16.8 11.5 13.4 1 16.8 11.1 0.4 0 0.4 0.4 46 4 48 305 20 0 20 0 -20.5 0.1 -20.2 -20.8 03/06/2005 03:20:00 14.7 1.1 17.6 11.8 14.5 1.2 17.6 11.8 0.4 0 0.4 0.4 41 5 41 305 20 0 20 0 -20.4 0 -20.1 -20.6 03/06/2005 03:30:00 14.1 1.1 17.9 11.1 13.8 1.1 16.4 11.1 0.4 0 0.4 0.4 41 5 36 305 20 0 20 0 -20.3 0.1 -20.1 -20.6 03/06/2005 03:40:00 14.7 0.8 16.8 12.2 14.5 0.9 17.2 12.2 0.4 0 0.4 0.4 36 5 42 305 20 0 20 0 -20.2 0 -20.1 -20.4 03/06/2005 03:50:00 14.4 1 17.2 11.1 14.2 1.1 17.2 11.5 0.4 0 0.4 0.4 42 5 36 305 20 0 20 0 -20.2 0 -20.1 -20.4 03/06/2005 04:00:00 14.6 1.3 17.2 11.5 14.5 1.3 17.2 11.1 0.4 0 0.4 0.4 44 5 48 305 20 0 20 0 -20.3 0.1 -20.1 -20.8 03/06/2005 04:10:00 15.2 1 17.2 12.6 15 1 16.8 11.5 0.4 0 0.4 0.4 44 3 43 305 20 0 20 0 -20.5 0.1 -20.2 -20.6 03/06/2005 04:20:00 14.4 1 16.4 11.5 14.2 1.1 16.1 10.3 0.4 0 0.4 0.4 47 3 48 305 19 0 20 0 -20.6 0 -20.2 -20.8 03/06/2005 04:30:00 13.5 1 15.6 11.5 13.3 1 16.1 10.7 0.4 0 0.4 0.4 48 4 48 305 19 0 19 0 -20.6 0 -20.4 -20.8 03/06/2005 04:40:00 14.1 0.8 16.4 11.8 13.9 0.8 16.1 11.8 0.4 0 0.4 0.4 47 5 45 305 19 0 19 0 -20.6 0 -20.2 -20.8 03/06/2005 04:50:00 14.2 1.3 17.9 11.8 14.1 1.4 17.6 11.1 0.4 0 0.4 0.4 41 4 38 305 19 0 19 0 -20.4 0.1 -20.1 -20.8 03/06/2005 05:00:00 15.6 1.2 18.7 13 15.4 1.1 17.9 12.6 0.4 0 0.4 0.4 45 5 44 305 19 0 19 0 -20.2 0 -19.9 -20.4 03/06/2005 05:10:00 14 1 17.2 11.8 13.8 1 16.4 11.5 0.4 0 0.4 0.4 45 5 45 305 20 0 19 0 -20.1 0 -19.7 -20.2 03/06/2005 05:20:00 16 1 18.7 13 15.8 1 18.3 13.3 0.4 0 0.4 0.4 46 5 50 305 20 0 20 0 -20.1 0.1 -19.7 -20.1 03/06/2005 05:30:00 15.8 1.1 18.3 13.3 15.6 1.1 18.7 12.6 0.4 0 0.4 0.4 44 4 44 305 20 0 20 0 -19.9 0.1 -19.5 -20.1 03/06/2005 05:40:00 15.7 1 18.3 13 15.6 1.1 17.9 12.6 0.4 0 0.4 0.4 44 3 46 305 20 0 20 0 -19.9 0 -19.7 -20.1 03/06/2005 05:50:00 15.4 0.9 18.3 13.3 15.2 0.9 18.3 13 0.4 0 0.4 0.4 46 4 49 305 21 0 21 0 -19.7 0 -19.5 -19.9 03/06/2005 06:00:00 15.8 1.2 18.3 13 15.4 1.3 18.3 12.2 0.4 0 0.4 0.4 46 4 48 305 21 0 21 0 -19.7 0 -19.3 -19.9 03/06/2005 06:10:00 14 1.3 16.8 11.1 13.6 1.4 16.8 10.7 0.4 0 0.4 0.4 45 5 43 305 21 0 21 0 -19.7 0 -19.5 -19.9 03/06/2005 06:20:00 14.2 1.2 17.9 11.5 14 1.3 17.6 11.1 0.4 0 0.4 0.4 46 4 48 305 21 0 21 0 -19.6 0 -19.5 -19.7 03/06/2005 06:30:00 13.6 1.1 15.6 10.7 13.3 1.2 15.6 10.3 0.4 0 0.4 0.4 41 5 45 305 21 0 21 0 -19.6 0 -19.5 -19.5 03/06/2005 06:40:00 14.1 1 16.4 11.5 14 1 16.4 11.5 0.4 0 0.4 0.4 42 4 40 305 21 0 21 0 -19.5 0 -19.3 -19.5 03/06/2005 06:50:00 15.3 1.1 17.9 12.2 15.2 1.1 17.9 11.8 0.4 0 0.4 0.4 45 4 46 305 21 0 21 0 -19.4 0 -19.2 -19.5 03/06/2005 07:00:00 14 1 16.4 11.1 13.7 1.1 16.8 11.1 0.4 0 0.4 0.4 43 4 41 305 22 0 22 0 -19.3 0 -19 -19.5 03/06/2005 07:10:00 14.1 0.9 16.1 11.8 13.9 1 16.4 11.5 0.4 0 0.4 0.4 42 5 45 305 22 0 22 0 -19.2 0 -19 -19.5 03/06/2005 07:20:00 15.5 1.1 18.3 12.6 15.4 1.2 18.7 12.6 0.4 0 0.4 0.4 43 4 44 305 22 0 22 0 -19.2 0 -19 -19.3 03/06/2005 07:30:00 14.4 1 17.6 12.2 14.2 1.1 17.2 11.8 0.4 0 0.4 0.4 45 4 46 305 22 0 22 0 -19.1 0 -19 -19.3 03/06/2005 07:40:00 14.2 0.8 16.4 12.2 14.1 0.9 16.8 11.8 0.4 0 0.4 0.4 45 4 48 305 22 0 22 0 -19.1 0 -18.8 -19 03/06/2005 07:50:00 14.4 0.9 16.4 12.2 14.2 1 16.4 11.8 0.4 0 0.4 0.4 46 5 40 305 22 0 22 0 -18.9 0.1 -18.4 -19 03/06/2005 08:00:00 14.7 0.9 16.8 12.6 14.6 1 17.2 11.8 0.4 0 0.4 0.4 45 4 43 305 23 0 23 0 -18.7 0 -18.4 -19 03/06/2005 08:10:00 16 0.9 17.9 13.3 15.9 1 18.7 13.3 0.4 0 0.4 0.4 45 4 48 305 23 0 23 0 -18.7 0 -18.4 -18.8 03/06/2005 08:20:00 16 1.1 18.3 13.3 15.9 1.1 17.9 13 0.4 0 0.4 0.4 45 4 44 305 23 0 23 0 -18.7 0 -18.2 -18.8 03/06/2005 08:30:00 16 1.1 18.7 12.6 15.9 1.2 18.7 12.6 0.4 0 0.4 0.4 48 4 45 305 23 0 23 0 -18.7 0.1 -18.2 -18.8 03/06/2005 08:40:00 15.5 0.9 17.6 13 15.2 1 17.6 13 0.4 0 0.4 0.4 50 4 43 305 23 0 24 0 -18.6 0 -18.2 -18.8 03/06/2005 08:50:00 15.4 0.8 17.2 13 15.2 0.9 17.2 12.6 0.4 0 0.4 0.4 47 4 47 305 23 0 24 0 -18.5 0 -18.1 -18.8 03/06/2005 09:00:00 16.5 1 19.1 13.3 16.4 1.2 18.7 13.3 0.4 0 0.4 0.4 51 5 56 305 24 0 24 0 -18.6 0.1 -18.1 -18.8 03/06/2005 09:10:00 15.8 1.1 18.7 12.6 15.6 1.2 18.3 12.6 0.4 0 0.4 0.4 51 4 51 305 24 0 24 0 -18.5 0.1 -18.1 -18.8 03/06/2005 09:20:00 15.6 1.2 18.7 12.2 15.3 1.3 18.3 11.8 0.4 0 0.4 0.4 49 5 51 305 24 0 24 0 -18.5 0.1 -18.1 -18.6 03/06/2005 09:30:00 15.9 1 18.3 13.3 15.8 1.1 18.3 12.6 0.4 0 0.4 0.4 48 4 43 305 24 0 24 0 -18.5 0.1 -18.1 -18.6 03/06/2005 09:40:00 16 1.2 18.7 13 15.8 1.2 19.1 13.3 0.4 0 0.4 0.4 47 4 44 305 24 0 24 0 -18.5 0.1 -18.1 -18.8 03/06/2005 09:50:00 16.2 0.8 18.3 13.7 16.1 0.9 18.3 13 0.4 0 0.4 0.4 49 5 40 305 24 0 24 0 -18.5 0.1 -18.1 -18.8 03/06/2005 10:00:00 15.8 0.9 17.6 13.3 15.7 1 17.9 12.6 0.4 0 0.4 0.4 51 4 50 305 24 0 24 0 -18.5 0.1 -18.1 -18.4 03/06/2005 10:10:00 15 1 17.2 12.2 14.8 1.2 17.6 11.5 0.4 0 0.4 0.4 48 4 46 305 24 0 24 0 -18.4 0.1 -18.1 -18.4 03/06/2005 10:20:00 15 1.2 17.9 12.6 14.8 1.2 17.9 11.5 0.4 0 0.4 0.4 46 4 41 305 24 0 24 0 -18.5 0 -18.1 -18.6 03/06/2005 10:30:00 15.4 1 18.3 12.2 15.2 1.1 17.6 12.2 0.4 0 0.4 0.4 46 4 39 305 24 0 24 0 -18.6 0 -18.1 -18.6 03/06/2005 10:40:00 14.3 1.2 17.6 11.1 14 1.3 17.6 10.7 0.4 0 0.4 0.4 47 5 47 305 24 0 24 0 -18.5 0 -18.1 -18.6 03/06/2005 10:50:00 14.1 1 17.2 12.2 13.9 1 17.2 11.8 0.4 0 0.4 0.4 48 4 49 305 24 0 24 0 -18.4 0.1 -18.1 -18.4 03/06/2005 11:00:00 15.7 1 17.9 12.6 15.4 1.1 17.6 12.6 0.4 0 0.4 0.4 48 4 51 305 24 0 25 0 -18.3 0 -17.9 -18.4 03/06/2005 11:10:00 15.9 1.3 18.7 12.6 15.6 1.4 18.7 11.8 0.4 0 0.4 0.4 49 4 46 305 25 0 25 0 -18.2 0 -18.1 -18.4 03/06/2005 11:20:00 16.5 1.2 19.1 13.3 16.1 1.3 19.1 12.2 0.4 0 0.4 0.4 47 3 51 305 25 0 25 0 -18.2 0 -18.1 -18.4 03/06/2005 11:30:00 16.6 1.3 19.1 13 16.3 1.3 19.1 12.2 0.4 0 0.4 0.4 52 4 57 305 25 0 25 0 -18.1 0 -17.9 -18.4 03/06/2005 11:40:00 15.1 1.1 17.9 12.2 14.8 1.3 17.9 11.8 0.4 0 0.4 0.4 49 6 48 305 25 0 25 0 -18.1 0 -17.7 -18.2 03/06/2005 11:50:00 14.8 1.1 17.6 11.8 14.6 1.2 17.6 10.7 0.4 0 0.4 0.4 48 5 47 305 26 0 26 0 -18.1 0 -17.9 -18.2 03/06/2005 12:00:00 15.9 1 18.7 13.3 15.7 1.1 18.3 12.6 0.4 0 0.4 0.4 51 4 42 305 26 0 26 0 -18 0 -17.5 -18.1 03/06/2005 12:10:00 14.4 1 16.8 11.5 14.1 1.2 16.8 11.1 0.4 0 0.4 0.4 51 5 58 305 26 0 26 0 -17.9 0.1 -17.5 -18.1 03/06/2005 12:20:00 14.8 1.1 17.6 11.5 14.5 1.2 17.6 11.5 0.4 0 0.4 0.4 47 5 44 305 26 0 26 0 -17.8 0.1 -17.5 -18.1 03/06/2005 12:30:00 14.2 1.2 16.8 11.1 13.8 1.3 16.8 10.7 0.4 0 0.4 0.4 46 5 42 305 26 0 26 0 -17.7 0.2 -17.3 -18.1 03/06/2005 12:40:00 13.4 1.3 16.8 10.3 13 1.4 16.4 9.9 0.4 0 0.4 0.4 51 5 50 305 27 0 27 0 -17.6 0.2 -17.1 -17.9 03/06/2005 12:50:00 13.3 1.3 16.8 9.9 12.9 1.5 16.8 9.9 0.4 0 0.4 0.4 47 5 46 305 27 0 27 0 -17.6 0.2 -17.1 -17.9 03/06/2005 13:00:00 13.1 1.3 15.6 10.3 12.7 1.5 16.1 9.5 0.4 0 0.4 0.4 46 5 48 305 27 0 27 0 -17.6 0.2 -17.1 -17.9 03/06/2005 13:10:00 13.4 1.3 16.4 9.9 13.1 1.3 16.1 9.9 0.4 0 0.4 0.4 45 8 37 305 27 0 27 0 -17.7 0.2 -17.1 -18.1 03/06/2005 13:20:00 14.3 1 16.4 11.5 14 1 16.4 10.7 0.4 0 0.4 0.4 45 5 46 305 27 0 27 0 -17.8 0.2 -17.5 -18.1 03/06/2005 13:30:00 14.3 1.1 16.8 11.1 13.9 1.2 16.4 9.5 0.4 0 0.4 0.4 45 5 45 305 27 0 27 0 -17.8 0.1 -17.3 -18.1 03/06/2005 13:40:00 13.3 0.8 16.1 10.7 13.2 0.9 16.1 9.9 0.4 0 0.4 0.4 48 4 54 305 27 0 27 0 -17.7 0.2 -17.3 -18.1 03/06/2005 13:50:00 14.4 1 16.8 11.8 14.2 1.1 16.8 11.8 0.4 0 0.4 0.4 49 4 48 305 27 0 27 0 -17.6 0.2 -17.1 -17.9 03/06/2005 14:00:00 14.2 0.9 16.4 11.5 14 1 16.4 11.1 0.4 0 0.4 0.4 50 4 51 305 27 0 27 0 -17.6 0.2 -17.1 -17.9 03/06/2005 14:10:00 12.5 1 14.9 9.1 12.2 1.1 14.5 8.8 0.4 0 0.4 0.4 46 6 40 305 27 0 27 0 -17.5 0.2 -17.1 -17.9 03/06/2005 14:20:00 12.7 1 16.1 9.9 12.4 1.2 15.6 9.9 0.4 0 0.4 0.4 40 5 42 305 27 0 27 0 -17.6 0.1 -17.1 -17.9 03/06/2005 14:30:00 13.1 1 16.4 10.7 12.9 1.1 16.1 10.3 0.4 0 0.4 0.4 45 5 40 305 28 0 28 0 -17.7 0.2 -17.1 -17.9 03/06/2005 14:40:00 15 1.1 17.6 11.8 14.7 1.2 17.9 11.8 0.4 0 0.4 0.4 48 6 52 305 28 0 28 0 -17.8 0.1 -17.3 -18.1 03/06/2005 14:50:00 13.6 1.1 16.1 10.7 13.3 1.2 16.1 9.9 0.4 0 0.4 0.4 49 5 54 305 27 0 27 0 -17.8 0 -17.5 -18.1 03/06/2005 15:00:00 13.9 1.1 16.4 11.5 13.6 1.2 16.1 10.3 0.4 0 0.4 0.4 45 4 45 305 28 0 28 0 -17.7 0 -17.1 -17.9 03/06/2005 15:10:00 13.5 1.1 17.2 11.5 13.2 1.2 16.8 10.7 0.4 0 0.4 0.4 44 4 40 305 28 0 28 0 -17.7 0 -17.5 -17.9 03/06/2005 15:20:00 14.9 1 17.9 11.8 14.7 1.1 17.2 11.8 0.4 0 0.4 0.4 48 4 49 305 28 0 28 0 -17.7 0 -17.1 -17.9 03/06/2005 15:30:00 14.3 0.9 16.4 11.5 14 1 15.6 11.5 0.4 0 0.4 0.4 47 4 47 305 28 0 28 0 -17.7 0 -17.5 -17.9 03/06/2005 15:40:00 13.7 0.9 16.4 10.7 13.5 1 16.1 9.9 0.4 0 0.4 0.4 45 4 38 305 28 0 28 0 -17.6 0 -17.3 -17.9 03/06/2005 15:50:00 14.2 0.9 16.8 12.2 13.9 1 16.8 11.1 0.4 0 0.4 0.4 46 4 39 305 28 0 28 0 -17.6 0 -17.3 -17.7 03/06/2005 16:00:00 13.1 0.8 14.9 10.7 12.8 0.9 14.9 10.3 0.4 0 0.4 0.4 46 5 45 305 28 0 28 0 -17.5 0.1 -16.9 -17.7 03/06/2005 16:10:00 13.9 1.1 16.1 11.1 13.7 1.3 16.1 9.9 0.4 0 0.4 0.4 44 4 46 305 28 0 28 0 -17.3 0.1 -16.9 -17.5 03/06/2005 16:20:00 14.4 0.8 16.4 10.7 14.1 1 16.4 10.7 0.4 0 0.4 0.4 46 4 50 305 29 0 29 0 -17.3 0.1 -16.9 -17.5 03/06/2005 16:30:00 13.9 0.8 16.1 11.5 13.6 0.9 16.1 10.7 0.4 0 0.4 0.4 44 4 49 305 29 0 29 0 -17.2 0 -16.9 -17.3 03/06/2005 16:40:00 14.8 1 17.2 11.8 14.5 1 16.8 11.8 0.4 0 0.4 0.4 44 4 44 305 29 0 29 0 -17.2 0 -16.7 -17.3 03/06/2005 16:50:00 13.9 0.9 16.1 11.5 13.6 1 15.6 11.1 0.4 0 0.4 0.4 43 4 50 305 30 0 29 0 -17 0.1 -16.4 -17.3 03/06/2005 17:00:00 14.3 0.8 16.4 12.2 14 0.8 16.1 11.1 0.4 0 0.4 0.4 43 4 45 305 30 0 30 0 -16.8 0.2 -16.4 -16.9 03/06/2005 17:10:00 13.9 1.3 17.2 10.7 13.5 1.3 16.8 11.1 0.4 0 0.4 0.4 39 5 37 305 31 0 31 0 -16.8 0.2 -16.4 -16.9 03/06/2005 17:20:00 14.3 1 16.8 12.2 13.9 1 17.2 11.5 0.4 0 0.4 0.4 43 4 38 305 31 0 31 0 -16.8 0.2 -16.4 -16.9 03/06/2005 17:30:00 14.7 1 17.2 12.2 14.3 1.1 17.2 11.8 0.4 0 0.4 0.4 37 4 41 305 31 0 31 0 -16.7 0.2 -16.4 -16.9 03/06/2005 17:40:00 15.3 0.8 17.2 12.2 15.1 0.8 16.8 12.6 0.4 0 0.4 0.4 40 4 38 305 31 0 31 0 -16.8 0.2 -16.4 -16.9 03/06/2005 17:50:00 15 0.8 17.6 13 14.7 1 16.8 11.5 0.4 0 0.4 0.4 43 4 43 305 31 0 31 0 -16.8 0.2 -16.4 -16.9 03/06/2005 18:00:00 14.5 1 16.4 11.8 14.2 1.1 16.4 11.5 0.4 0 0.4 0.4 43 5 43 305 30 0 31 0 -16.7 0.2 -16.2 -16.9 03/06/2005 18:10:00 15.7 1.1 18.3 12.6 15.4 1.2 17.9 11.8 0.4 0 0.4 0.4 42 5 41 305 30 0 31 0 -16.7 0.2 -16.4 -16.9 03/06/2005 18:20:00 16.1 1.1 19.1 13.7 15.8 1.1 18.7 13 0.4 0 0.4 0.4 44 5 46 305 30 0 31 0 -16.8 0.2 -16.4 -16.9 03/06/2005 18:30:00 15.8 1.1 18.3 12.6 15.5 1.1 17.9 12.6 0.4 0 0.4 0.4 42 5 41 305 30 0 30 0 -16.8 0.1 -16.4 -16.9 03/06/2005 18:40:00 15.3 1 17.9 12.6 15.1 1 17.6 12.6 0.4 0 0.4 0.4 44 4 41 305 30 0 30 0 -16.8 0.2 -16.4 -16.9 03/06/2005 18:50:00 15.8 1.2 18.3 13.3 15.6 1.3 18.7 13 0.4 0 0.4 0.4 43 5 35 305 30 0 29 0 -16.8 0.2 -16.4 -16.9 03/06/2005 19:00:00 15.7 0.9 17.9 13.3 15.5 1 17.6 12.2 0.4 0 0.4 0.4 45 4 44 305 29 0 29 0 -16.8 0.2 -16.4 -16.9 03/06/2005 19:10:00 14.9 0.9 16.8 12.2 14.6 1 16.8 12.2 0.4 0 0.4 0.4 41 4 41 305 29 0 29 0 -16.8 0.1 -16.4 -16.9 03/06/2005 19:20:00 15.5 1 17.9 12.6 15.3 1.1 17.6 12.2 0.4 0 0.4 0.4 41 4 41 305 29 0 29 0 -16.9 0 -16.6 -16.9 03/06/2005 19:30:00 16.3 1.1 18.3 13.3 16.1 1.2 17.9 12.6 0.4 0 0.4 0.4 40 4 40 305 29 0 29 0 -16.9 0 -16.9 -16.9 03/06/2005 19:40:00 15.3 1.2 18.3 12.2 15 1.3 18.3 12.2 0.4 0 0.4 0.4 39 5 39 305 29 0 29 0 -16.9 0 -16.7 -16.9 03/06/2005 19:50:00 16.1 1 18.7 13.3 15.9 1 18.7 13.3 0.4 0 0.4 0.4 40 5 36 305 29 0 29 0 -16.9 0 -16.9 -16.9 03/06/2005 20:00:00 16.8 0.9 18.7 14.5 16.6 0.9 18.7 14.1 0.4 0 0.4 0.4 42 4 44 305 29 0 29 0 -17 0.1 -16.6 -17.3 03/06/2005 20:10:00 16.5 1 18.7 14.1 16.2 1.1 18.7 13 0.4 0 0.4 0.4 41 5 36 305 28 0 28 0 -17.2 0 -16.6 -17.3 03/06/2005 20:20:00 16.1 1.2 18.3 13.3 15.8 1.2 18.7 12.2 0.4 0 0.4 0.4 41 5 44 305 28 0 28 0 -17.2 0 -16.7 -17.3 03/06/2005 20:30:00 16 1.2 18.7 12.6 15.7 1.2 18.3 11.8 0.4 0 0.4 0.4 43 4 48 305 28 0 28 0 -17.2 0 -16.6 -17.3 03/06/2005 20:40:00 15.1 1 17.6 11.8 14.9 1.1 17.6 12.2 0.4 0 0.4 0.4 46 4 44 305 28 0 28 0 -17.1 0 -16.7 -17.3 03/06/2005 20:50:00 15.2 1.2 18.3 12.2 15 1.2 17.9 11.5 0.4 0 0.4 0.4 41 4 42 305 28 0 28 0 -17.1 0 -16.6 -17.3 03/06/2005 21:00:00 16.6 0.9 18.7 14.1 16.3 1 19.1 13 0.4 0 0.4 0.4 43 3 44 305 28 0 28 0 -17.2 0 -16.9 -17.5 03/06/2005 21:10:00 15.7 1.3 19.1 12.2 15.5 1.3 18.7 12.2 0.4 0 0.4 0.4 46 5 42 305 28 0 28 0 -17.2 0 -16.9 -17.3 03/06/2005 21:20:00 15.6 1 18.3 13.3 15.4 1.1 18.7 12.6 0.4 0 0.4 0.4 45 5 44 305 28 0 28 0 -17.1 0 -16.9 -17.3 03/06/2005 21:30:00 16.3 1 18.7 13.3 16 1.1 18.7 12.6 0.4 0 0.4 0.4 44 4 46 305 28 0 28 0 -17.1 0.1 -16.6 -17.3 03/06/2005 21:40:00 15.3 1 17.6 12.6 15.2 1 17.6 12.6 0.4 0 0.4 0.4 43 4 46 305 28 0 28 0 -16.9 0.1 -16.6 -17.1 03/06/2005 21:50:00 15.5 1.3 18.7 12.2 15.2 1.4 17.9 12.2 0.4 0 0.4 0.4 39 5 33 305 28 0 28 0 -16.9 0.1 -16.4 -17.1 03/06/2005 22:00:00 16.1 1.1 18.7 13.7 16 1.1 19.1 12.6 0.4 0 0.4 0.4 41 4 34 305 28 0 28 0 -16.8 0.1 -16.4 -16.9 03/06/2005 22:10:00 16.2 1.1 19.5 13 15.9 1.2 19.5 13 0.4 0 0.4 0.4 39 5 36 305 28 0 28 0 -16.8 0.2 -16.4 -16.9 03/06/2005 22:20:00 15.9 1.1 18.3 13 15.6 1.1 18.3 12.6 0.4 0 0.4 0.4 40 4 43 305 28 0 28 0 -16.8 0.1 -16.4 -16.9 03/06/2005 22:30:00 16.1 1.2 19.1 12.6 15.9 1.2 18.7 13 0.4 0 0.4 0.4 40 4 39 305 28 0 28 0 -16.8 0.1 -16.4 -17.1 03/06/2005 22:40:00 16.5 1 18.7 13.3 16.3 1 18.7 13.3 0.4 0 0.4 0.4 40 5 35 305 28 0 28 0 -16.8 0.2 -16.4 -16.9 03/06/2005 22:50:00 16.5 1.7 19.9 13.3 16.3 1.7 19.9 12.2 0.4 0 0.4 0.4 43 4 45 305 29 0 28 0 -16.8 0.1 -16.4 -16.9 03/06/2005 23:00:00 17.4 1.1 20.2 14.1 17.1 1.2 20.2 13.7 0.4 0 0.4 0.4 39 6 41 305 28 0 28 0 -16.9 0.1 -16.6 -16.9 03/06/2005 23:10:00 17.2 1 19.5 14.1 16.9 1.1 19.9 13.3 0.4 0 0.4 0.4 42 3 39 305 28 0 28 0 -16.8 0.1 -16.4 -16.9 03/06/2005 23:20:00 16.8 1.1 19.5 13.7 16.5 1.2 19.1 13.3 0.4 0 0.4 0.4 40 5 41 305 28 0 28 0 -16.8 0.2 -16.4 -16.9 03/06/2005 23:30:00 17.1 1.6 20.6 13.3 16.8 1.5 20.6 13 0.4 0 0.4 0.4 37 6 33 305 28 0 28 0 -16.9 0.1 -16.4 -17.1 03/06/2005 23:40:00 15.7 1.2 19.1 12.6 15.5 1.3 19.1 12.2 0.4 0 0.4 0.4 41 4 35 305 28 0 28 0 -16.8 0.1 -16.4 -16.9 03/06/2005 23:50:00 15.2 1.1 17.6 12.2 15 1.1 17.9 11.8 0.4 0 0.4 0.4 43 4 42 305 29 0 28 0 -16.9 0 -16.6 -16.9 03/07/2005 00:00:00 16.1 1.4 19.5 12.6 15.9 1.5 19.5 12.2 0.4 0 0.4 0.4 42 5 33 305 29 0 28 0 -16.9 0 -16.4 -17.1 03/07/2005 00:10:00 15.3 1.1 18.3 13 15.1 1.1 17.9 12.6 0.4 0 0.4 0.4 42 4 40 305 29 0 29 0 -17 0 -16.6 -17.3 03/07/2005 00:20:00 15.3 1.6 18.7 11.1 15.1 1.6 18.7 10.7 0.4 0 0.4 0.4 35 5 33 305 28 0 28 0 -16.9 0 -16.6 -16.9 03/07/2005 00:30:00 15.2 1.5 17.9 12.2 14.9 1.5 17.9 11.8 0.4 0 0.4 0.4 31 5 26 305 28 0 28 0 -16.9 0 -16.6 -16.9 03/07/2005 00:40:00 13.8 1.1 16.4 10.7 13.5 1.1 15.6 10.7 0.4 0 0.4 0.4 33 6 31 305 28 0 28 0 -16.9 0 -16.4 -16.9 03/07/2005 00:50:00 13.5 1.2 16.4 10.3 13.3 1.2 16.1 10.7 0.4 0 0.4 0.4 36 6 31 305 28 0 28 0 -16.9 0 -16.4 -16.9 03/07/2005 01:00:00 15.3 1.7 19.1 11.5 15.1 1.7 19.1 11.5 0.4 0 0.4 0.4 38 5 36 305 28 0 28 0 -16.9 0.1 -16.4 -16.9 03/07/2005 01:10:00 14.5 1.5 17.9 10.7 14.3 1.5 17.6 10.7 0.4 0 0.4 0.4 37 6 36 305 29 0 28 0 -16.9 0 -16.4 -16.9 03/07/2005 01:20:00 14.9 1.3 18.3 11.1 14.7 1.4 17.9 11.1 0.4 0 0.4 0.4 40 5 37 305 29 0 28 0 -16.9 0 -16.4 -16.9 03/07/2005 01:30:00 14.9 1.6 18.3 10.3 14.8 1.7 18.7 11.1 0.4 0 0.4 0.4 37 5 36 305 29 0 28 0 -16.8 0.1 -16.2 -16.9 03/07/2005 01:40:00 14.5 1.3 17.2 10.7 14.1 1.3 16.8 10.3 0.4 0 0.4 0.4 36 5 40 305 29 0 29 0 -16.8 0.1 -16.2 -16.9 03/07/2005 01:50:00 14.3 1.3 17.2 10.3 14 1.4 17.6 9.5 0.4 0 0.4 0.4 32 5 29 305 29 0 29 0 -16.7 0 -16 -16.9 03/07/2005 02:00:00 15.1 1.4 18.3 11.5 14.8 1.4 18.3 11.1 0.4 0 0.4 0.4 34 5 40 305 29 0 29 0 -16.5 0.1 -16 -16.6 03/07/2005 02:10:00 15 1.6 18.3 10.7 14.6 1.5 18.3 10.7 0.4 0 0.4 0.4 32 5 32 305 29 0 29 0 -16.4 0.1 -16 -16.7 03/07/2005 02:20:00 15.8 1.7 19.5 11.5 15.5 1.7 19.1 11.5 0.4 0 0.4 0.4 34 5 32 305 29 0 29 0 -16.4 0.1 -16 -16.6 03/07/2005 02:30:00 14.4 1.7 18.3 10.7 14.1 1.8 18.3 9.9 0.4 0 0.4 0.4 34 5 35 305 29 0 29 0 -16.2 0.1 -15.8 -16.6 03/07/2005 02:40:00 14.9 1.5 18.3 11.1 14.6 1.5 17.9 11.1 0.4 0 0.4 0.4 33 5 30 305 30 0 30 0 -16.2 0.1 -15.8 -16.4 03/07/2005 02:50:00 13.9 1.5 17.2 10.7 13.8 1.5 17.2 10.3 0.4 0 0.4 0.4 34 5 35 305 30 0 30 0 -16.1 0.2 -15.6 -16.4 03/07/2005 03:00:00 14.8 1 17.2 11.8 14.5 1.1 17.2 11.5 0.4 0 0.4 0.4 34 6 27 305 30 0 30 0 -16.1 0.2 -15.8 -16.4 03/07/2005 03:10:00 14.5 1.2 18.7 11.8 14.2 1.2 18.3 11.5 0.4 0 0.4 0.4 40 5 36 305 30 0 31 0 -16.1 0.2 -15.6 -16.4 03/07/2005 03:20:00 15.7 1 19.1 13 15.4 1.1 17.9 13 0.4 0 0.4 0.4 41 5 37 305 31 0 31 0 -16.2 0.2 -15.8 -16.6 03/07/2005 03:30:00 14.8 1.4 19.1 11.5 14.6 1.5 18.7 10.7 0.4 0 0.4 0.4 36 6 31 305 31 0 31 0 -16.2 0.2 -15.8 -16.6 03/07/2005 03:40:00 15.9 1.2 19.1 12.2 15.6 1.3 19.1 11.8 0.4 0 0.4 0.4 35 5 30 305 31 0 31 0 -16.1 0.2 -15.6 -16.4 03/07/2005 03:50:00 15.3 1.3 18.3 12.2 15 1.3 18.3 12.2 0.4 0 0.4 0.4 32 5 26 305 31 0 31 0 -16.1 0.1 -15.6 -16.4 03/07/2005 04:00:00 15.4 1.5 18.7 11.5 15.1 1.4 18.7 11.8 0.4 0 0.4 0.4 34 5 39 305 31 0 31 0 -16 0.1 -15.6 -16.4 03/07/2005 04:10:00 14.3 1.5 17.2 10.3 14 1.4 17.6 10.7 0.4 0 0.4 0.4 34 5 32 305 31 0 31 0 -16 0.1 -15.6 -16.2 03/07/2005 04:20:00 14.6 1.5 19.1 11.1 14.3 1.5 18.7 11.1 0.4 0 0.4 0.4 35 5 40 305 31 0 31 0 -16 0 -15.6 -16.2 03/07/2005 04:30:00 13.7 1.1 16.4 11.1 13.5 1.1 16.4 11.1 0.4 0 0.4 0.4 40 5 38 305 31 0 31 0 -16 0 -15.4 -16.2 03/07/2005 04:40:00 14.7 1.8 19.5 11.5 14.3 1.8 19.5 11.5 0.4 0 0.4 0.4 36 6 27 305 31 0 31 0 -16.1 0.1 -15.6 -16.4 03/07/2005 04:50:00 16.3 1.3 19.5 13 15.9 1.3 19.1 12.6 0.4 0 0.4 0.4 34 5 31 305 31 0 31 0 -16.2 0 -15.6 -16.4 03/07/2005 05:00:00 15.2 1.5 18.7 11.8 15 1.5 18.7 11.8 0.4 0 0.4 0.4 37 5 32 305 31 0 31 0 -16.1 0.1 -15.6 -16.4 03/07/2005 05:10:00 16.1 1.3 19.1 12.6 15.9 1.4 19.1 12.2 0.4 0 0.4 0.4 39 5 36 305 31 0 31 0 -16 0 -15.8 -16.2 03/07/2005 05:20:00 14.2 1.1 17.2 11.5 13.9 1.2 16.8 11.5 0.4 0 0.4 0.4 40 5 48 305 31 0 31 0 -16 0 -15.6 -16.2 03/07/2005 05:30:00 14.8 1.4 18.7 11.5 14.6 1.4 17.9 11.5 0.4 0 0.4 0.4 37 5 41 305 31 0 32 0 -16 0 -15.6 -16.2 03/07/2005 05:40:00 16.5 1.3 19.5 12.6 16.3 1.3 19.5 11.8 0.4 0 0.4 0.4 41 5 36 305 32 0 32 0 -16 0 -15.6 -16 03/07/2005 05:50:00 16.2 1.3 19.1 13 16 1.2 19.1 13 0.4 0 0.4 0.4 41 5 38 305 32 0 32 0 -15.9 0 -15.6 -16 03/07/2005 06:00:00 15.3 1.2 18.3 12.6 15.1 1.2 18.3 11.8 0.4 0 0.4 0.4 41 5 38 305 32 0 32 0 -16 0 -15.6 -16.2 03/07/2005 06:10:00 12.9 1 15.6 10.7 12.7 1 15.3 10.3 0.4 0 0.4 0.4 35 5 35 305 32 0 32 0 -15.9 0 -15.6 -16.2 03/07/2005 06:20:00 13.9 1.3 18.3 11.5 13.7 1.3 18.7 10.3 0.4 0 0.4 0.4 38 5 45 305 32 0 32 0 -16.1 0 -15.6 -16.2 03/07/2005 06:30:00 14.1 0.9 17.2 12.2 14 1 17.2 11.5 0.4 0 0.4 0.4 38 5 39 305 32 0 32 0 -16 0.1 -15.6 -16.2 03/07/2005 06:40:00 14.6 1.6 19.1 11.1 14.4 1.6 19.5 10.7 0.4 0 0.4 0.4 38 6 44 305 32 0 32 0 -15.9 0.1 -15.6 -16.2 03/07/2005 06:50:00 14.1 1.3 17.2 10.7 14 1.3 17.6 11.1 0.4 0 0.4 0.4 37 6 43 305 32 0 32 0 -15.9 0.1 -15.6 -16.2 03/07/2005 07:00:00 14.3 1.2 17.6 10.7 14 1.3 17.2 10.7 0.4 0 0.4 0.4 39 6 38 305 32 0 32 0 -16 0.2 -15.6 -16.2 03/07/2005 07:10:00 12.8 1.1 16.1 9.9 12.5 1.2 16.1 9.5 0.4 0 0.4 0.4 37 6 33 305 32 0 32 0 -15.9 0.1 -15.6 -16.2 03/07/2005 07:20:00 14.2 2.2 18.7 9.9 13.9 2.1 18.7 9.9 0.4 0 0.4 0.4 37 6 31 305 32 0 32 0 -15.9 0.2 -15.6 -16.2 03/07/2005 07:30:00 15.4 1.4 19.5 11.5 15.1 1.4 19.1 10.7 0.4 0 0.4 0.4 37 6 32 305 32 0 32 0 -16 0.1 -15.6 -16.2 03/07/2005 07:40:00 14 1.2 17.2 11.1 13.8 1.3 17.2 10.7 0.4 0 0.4 0.4 40 6 33 305 32 0 32 0 -16 0.1 -15.6 -16.2 03/07/2005 07:50:00 14.3 1.3 17.6 10.7 14 1.4 17.6 10.7 0.4 0 0.4 0.4 36 6 40 305 32 0 32 0 -15.9 0.1 -15.6 -16.2 03/07/2005 08:00:00 13.6 1.4 17.9 10.3 13.5 1.4 18.3 10.3 0.4 0 0.4 0.4 36 6 31 305 32 0 32 0 -15.9 0.1 -15.4 -16 03/07/2005 08:10:00 14.4 1.7 18.7 10.3 14.2 1.7 18.7 10.3 0.4 0 0.4 0.4 37 5 38 305 32 0 32 0 -15.9 0.1 -15.6 -16.2 03/07/2005 08:20:00 13.3 1.5 17.6 9.5 13.1 1.6 16.8 9.9 0.4 0 0.4 0.4 34 6 29 305 32 0 32 0 -16 0.1 -15.6 -16.2 03/07/2005 08:30:00 14.3 1.3 17.6 11.1 14.1 1.2 17.2 11.1 0.4 0 0.4 0.4 33 6 28 305 32 0 32 0 -16 0.1 -15.6 -16.4 03/07/2005 08:40:00 13.8 1.7 17.6 9.9 13.5 1.7 17.6 9.9 0.4 0 0.4 0.4 35 6 33 305 32 0 32 0 -15.9 0.1 -15.6 -16.2 03/07/2005 08:50:00 13.7 1.5 17.6 10.3 13.4 1.5 17.2 9.9 0.4 0 0.4 0.4 37 6 42 305 32 0 32 0 -16 0.1 -15.6 -16.2 03/07/2005 09:00:00 12.7 1.1 15.3 9.5 12.6 1.2 16.1 9.5 0.4 0 0.4 0.4 37 6 44 305 32 0 32 0 -16.2 0.1 -15.6 -16.4 03/07/2005 09:10:00 13.8 1.4 17.6 10.3 13.6 1.5 17.6 10.3 0.4 0 0.4 0.4 38 6 46 305 32 0 32 0 -16.2 0 -16 -16.4 03/07/2005 09:20:00 14.3 1.3 17.2 9.9 14.1 1.3 17.2 10.3 0.4 0 0.4 0.4 39 5 44 305 31 0 32 0 -16 0 -15.6 -16.2 03/07/2005 09:30:00 14.6 1.3 17.9 11.8 14.4 1.3 18.3 11.1 0.4 0 0.4 0.4 35 5 39 305 31 0 32 0 -16 0 -15.8 -16 03/07/2005 09:40:00 15.1 1.4 18.7 11.1 14.9 1.4 18.3 11.8 0.4 0 0.4 0.4 35 4 31 305 32 0 32 0 -16 0 -15.8 -16 03/07/2005 09:50:00 12.8 1.4 16.8 9.5 12.7 1.3 17.6 9.9 0.4 0 0.4 0.4 35 6 35 305 32 0 32 0 -15.9 0 -15.6 -16 03/07/2005 10:00:00 15.3 1.6 18.3 11.1 15 1.5 18.7 10.7 0.4 0 0.4 0.4 32 5 27 305 32 0 32 0 -15.9 0 -15.4 -16 03/07/2005 10:10:00 15.6 1.9 21 11.8 15.2 1.9 20.2 11.1 0.4 0 0.4 0.4 31 6 28 305 32 0 32 0 -16 0 -15.4 -16.2 03/07/2005 10:20:00 15.8 1.8 21 11.5 15.6 1.7 20.2 12.2 0.4 0 0.4 0.4 37 5 38 305 32 0 32 0 -16.1 0 -15.6 -16.2 03/07/2005 10:30:00 15.1 1.5 19.1 11.8 14.8 1.5 19.1 11.8 0.4 0 0.4 0.4 34 5 32 305 32 0 32 0 -16.1 0.1 -15.6 -16.4 03/07/2005 10:40:00 15.4 1.7 19.5 11.8 15 1.6 19.9 11.5 0.4 0 0.4 0.4 36 5 35 305 32 0 32 0 -16.1 0 -15.6 -16.4 03/07/2005 10:50:00 16.5 1.3 19.9 13.7 16 1.2 19.1 13.3 0.4 0 0.4 0.4 38 5 35 305 32 0 32 0 -16.3 0 -15.8 -16.4 03/07/2005 11:00:00 15.9 1.3 19.1 12.2 15.7 1.3 19.1 12.2 0.4 0 0.4 0.4 40 5 46 305 32 0 32 0 -16.3 0.1 -15.8 -16.4 03/07/2005 11:10:00 16.6 1.3 20.2 12.6 16.3 1.3 19.9 13 0.4 0 0.4 0.4 42 5 44 305 32 0 32 0 -16.2 0.2 -15.8 -16.4 03/07/2005 11:20:00 16.9 1.1 19.9 14.5 16.6 1.2 20.2 13.7 0.4 0 0.4 0.4 42 5 51 305 32 0 32 0 -16.1 0.2 -15.6 -16.4 03/07/2005 11:30:00 16.7 1.5 20.6 12.6 16.4 1.5 20.6 13 0.4 0 0.4 0.4 38 5 41 305 33 0 33 0 -16.1 0.2 -15.6 -16.4 03/07/2005 11:40:00 17.2 1.7 21.8 13.3 16.8 1.7 20.6 13.3 0.4 0 0.4 0.4 39 5 40 305 33 0 33 0 -16.1 0.2 -15.6 -16.4 03/07/2005 11:50:00 15 1.3 18.3 11.8 14.8 1.3 17.9 11.5 0.4 0 0.4 0.4 37 5 47 305 34 0 34 0 -16.1 0.1 -15.6 -16.4 03/07/2005 12:00:00 15.3 1.4 18.3 12.2 15.1 1.3 17.9 11.8 0.4 0 0.4 0.4 31 5 29 305 35 0 35 0 -16.1 0.2 -15.6 -16.4 03/07/2005 12:10:00 15.2 1.2 17.9 12.2 15 1.2 17.6 12.2 0.4 0 0.4 0.4 35 5 28 305 35 0 35 0 -15.9 0.2 -15.6 -16.2 03/07/2005 12:20:00 16.6 1.4 20.2 12.6 16.3 1.3 20.2 12.6 0.4 0 0.4 0.4 37 5 30 305 36 0 36 0 -16 0.2 -15.6 -16.4 03/07/2005 12:30:00 15.4 1.5 19.1 12.2 15.2 1.4 19.1 12.2 0.4 0 0.4 0.4 39 5 35 305 36 0 36 0 -15.9 0.2 -15.4 -16.2 03/07/2005 12:40:00 15.5 1.2 18.3 12.6 15.2 1.2 18.7 12.2 0.4 0 0.4 0.4 40 5 44 305 37 0 37 0 -15.8 0.2 -15.2 -16 03/07/2005 12:50:00 15.2 1.1 18.7 13 15 1.2 18.3 12.6 0.4 0 0.4 0.4 40 5 36 305 38 0 38 0 -15.7 0.1 -15.2 -16 03/07/2005 13:00:00 15.5 1.2 17.9 12.2 15.3 1.2 18.3 12.2 0.4 0 0.4 0.4 41 5 41 305 38 0 38 0 -15.7 0.1 -15.2 -16 03/07/2005 13:10:00 16.1 1.2 18.7 12.6 15.9 1.2 18.3 12.6 0.4 0 0.4 0.4 41 5 42 305 39 0 39 0 -15.7 0.2 -15.2 -16 03/07/2005 13:20:00 16.7 1 18.7 13.3 16.3 1 18.7 13.3 0.4 0 0.4 0.4 37 3 36 305 39 0 39 0 -15.8 0.1 -15.4 -16.2 03/07/2005 13:30:00 14.8 1.6 18.7 11.5 14.5 1.5 18.3 11.5 0.4 0 0.4 0.4 39 5 34 305 39 0 39 0 -15.8 0 -15.6 -16 03/07/2005 13:40:00 14.1 1.1 17.2 11.1 13.7 1.2 17.2 11.5 0.4 0 0.4 0.4 38 5 36 305 39 0 39 0 -15.8 0 -15.4 -15.8 03/07/2005 13:50:00 14.1 1.3 16.8 10.7 13.7 1.3 16.8 10.7 0.4 0 0.4 0.4 34 6 29 305 39 0 38 0 -15.8 0 -15.6 -16 03/07/2005 14:00:00 13.2 1.3 16.4 10.3 13 1.3 16.1 9.9 0.4 0 0.4 0.4 39 6 38 305 38 0 38 0 -15.8 0 -15.2 -16 03/07/2005 14:10:00 14.7 1 16.8 11.8 14.4 1.1 16.4 11.1 0.4 0 0.4 0.4 37 5 39 305 37 0 37 0 -15.8 0 -15.6 -16 03/07/2005 14:20:00 14.3 1.1 17.2 11.8 14.1 1.1 16.8 11.1 0.4 0 0.4 0.4 33 4 33 305 38 0 38 0 -15.8 0 -15.6 -15.8 03/07/2005 14:30:00 14.5 1 16.4 11.8 14.3 1 16.4 11.8 0.4 0 0.4 0.4 37 4 41 305 39 0 39 0 -15.8 0 -15.4 -15.8 03/07/2005 14:40:00 13.7 1.2 16.4 10.3 13.6 1.3 17.2 10.7 0.4 0 0.4 0.4 37 4 41 305 39 0 39 0 -15.6 0 -15.2 -15.8 03/07/2005 14:50:00 12.7 1.1 15.3 10.3 12.5 1.2 15.3 10.3 0.4 0 0.4 0.4 39 5 44 305 40 0 40 0 -15.4 0 -15 -15.6 03/07/2005 15:00:00 13.2 1 15.3 10.3 12.9 1.1 15.3 9.9 0.4 0 0.4 0.4 42 4 43 305 40 0 40 0 -15.3 0.1 -14.8 -15.6 03/07/2005 15:10:00 13.2 1 15.6 11.1 12.9 1 15.6 10.3 0.4 0 0.4 0.4 42 5 51 305 41 0 41 0 -15.1 0.1 -14.6 -15.2 03/07/2005 15:20:00 13.8 1.2 16.1 10.7 13.7 1.3 16.4 10.7 0.4 0 0.4 0.4 44 4 39 305 41 0 41 0 -15.1 0.1 -14.8 -15.2 03/07/2005 15:30:00 12.9 1.4 16.1 9.9 12.7 1.4 16.1 9.1 0.4 0 0.4 0.4 42 5 33 305 41 0 41 0 -15.2 0.1 -14.8 -15.2 03/07/2005 15:40:00 12.3 1 14.5 9.5 12.2 1 14.1 9.5 0.4 0 0.4 0.4 42 6 42 305 41 0 41 0 -15.1 0.2 -14.6 -15.4 03/07/2005 15:50:00 13.3 1.2 16.1 9.5 13 1.3 16.1 9.5 0.4 0 0.4 0.4 36 7 33 305 42 0 42 0 -14.9 0.1 -14.3 -15 03/07/2005 16:00:00 12.3 1.1 14.9 9.5 12.1 1.1 14.9 9.5 0.4 0 0.4 0.4 40 6 29 305 42 0 42 0 -14.7 0.1 -14.3 -15 03/07/2005 16:10:00 13.2 1.3 16.4 9.5 13 1.3 16.1 9.5 0.4 0 0.4 0.4 41 5 39 305 43 0 42 0 -14.8 0.2 -14.4 -15 03/07/2005 16:20:00 14.8 1.4 17.9 10.7 14.6 1.5 17.6 10.3 0.4 0 0.4 0.4 43 5 45 305 43 0 43 0 -15 0.2 -14.6 -15.4 03/07/2005 16:30:00 15 1.5 19.5 11.5 14.7 1.5 18.7 11.5 0.4 0 0.4 0.4 40 6 44 305 42 0 42 0 -15.1 0.2 -14.6 -15.4 03/07/2005 16:40:00 15.1 1.5 18.7 11.1 14.9 1.5 18.3 10.7 0.4 0 0.4 0.4 36 5 34 305 42 0 42 0 -14.9 0.2 -14.3 -15.2 03/07/2005 16:50:00 15.4 1.2 18.3 11.8 15.1 1.3 19.1 11.5 0.4 0 0.4 0.4 33 5 33 305 42 0 42 0 -14.9 0.2 -14.4 -15.2 03/07/2005 17:00:00 15.4 1.3 17.9 11.5 15 1.2 17.9 11.8 0.4 0 0.4 0.4 35 5 33 305 42 0 42 0 -15 0.1 -14.6 -15.2 03/07/2005 17:10:00 15.2 1.4 18.3 11.1 14.9 1.4 18.3 11.8 0.4 0 0.4 0.4 36 5 35 305 42 0 42 0 -15 0.1 -14.4 -15 03/07/2005 17:20:00 15.9 1.5 19.1 13 15.6 1.5 19.1 11.5 0.4 0 0.4 0.4 39 6 40 305 41 0 41 0 -14.9 0.2 -14.4 -15 03/07/2005 17:30:00 14.5 1.7 19.1 10.7 14.2 1.6 19.1 10.7 0.4 0 0.4 0.4 36 6 34 305 41 0 41 0 -15.1 0.2 -14.6 -15.2 03/07/2005 17:40:00 14.2 1.5 18.7 10.3 14 1.5 17.9 10.3 0.4 0 0.4 0.4 38 6 38 305 40 0 40 0 -15.2 0.1 -14.6 -15.4 03/07/2005 17:50:00 14.4 1.4 17.6 10.7 14.2 1.3 17.2 10.7 0.4 0 0.4 0.4 38 5 37 305 40 0 40 0 -15.4 0.2 -14.8 -15.6 03/07/2005 18:00:00 13.7 1.4 16.8 9.5 13.4 1.3 16.8 8.8 0.4 0 0.4 0.4 34 6 37 305 40 0 40 0 -15.5 0 -15 -15.6 03/07/2005 18:10:00 14.5 1.2 17.2 11.5 14.1 1.3 17.2 10.3 0.4 0 0.4 0.4 34 5 29 305 39 0 39 0 -15.7 0.1 -15.2 -15.8 03/07/2005 18:20:00 13.8 1.1 16.4 11.5 13.4 1.2 16.4 10.3 0.4 0 0.4 0.4 29 4 28 305 38 0 38 0 -15.6 0 -15 -15.8 03/07/2005 18:30:00 13.5 1.3 17.2 10.7 13.3 1.4 17.2 9.9 0.4 0 0.4 0.4 30 5 22 305 37 0 37 0 -15.5 0 -15.2 -15.6 03/07/2005 18:40:00 14.6 1.3 17.2 11.5 14.3 1.2 16.8 10.3 0.4 0 0.4 0.4 28 5 25 305 37 0 37 0 -15.6 0 -15.2 -15.8 03/07/2005 18:50:00 15 1.4 17.9 11.5 14.6 1.3 18.7 11.5 0.4 0 0.4 0.4 32 5 35 305 37 0 36 0 -15.6 0 -15 -15.8 03/07/2005 19:00:00 14.8 1.6 18.3 11.1 14.5 1.5 18.3 11.1 0.4 0 0.4 0.4 35 5 45 305 36 0 36 0 -15.5 0 -15 -15.6 03/07/2005 19:10:00 14.8 1.5 18.3 11.1 14.6 1.3 17.9 11.5 0.4 0 0.4 0.4 37 6 44 305 36 0 36 0 -15.5 0 -15 -15.6 03/07/2005 19:20:00 15.2 1.5 18.3 11.5 14.9 1.6 18.3 10.7 0.4 0 0.4 0.4 36 5 39 305 35 0 35 0 -15.5 0 -15.2 -15.6 03/07/2005 19:30:00 14 1.2 16.8 10.7 13.8 1.2 16.4 10.7 0.4 0 0.4 0.4 36 5 32 305 35 0 35 0 -15.4 0 -15 -15.6 03/07/2005 19:40:00 15.3 1.1 17.9 12.2 14.9 1.2 18.3 12.2 0.4 0 0.4 0.4 37 5 43 305 35 0 35 0 -15.3 0 -15 -15.6 03/07/2005 19:50:00 13.5 1.3 16.4 10.3 13.2 1.4 16.4 9.5 0.4 0 0.4 0.4 37 5 42 305 35 0 35 0 -15.3 0 -15 -15.6 03/07/2005 20:00:00 15.9 1.6 19.9 11.1 15.6 1.7 19.5 11.1 0.4 0 0.4 0.4 36 5 35 305 35 0 35 0 -15.3 0 -14.8 -15.6 03/07/2005 20:10:00 15.9 1.5 19.9 11.8 15.5 1.6 19.5 11.5 0.4 0 0.4 0.4 35 5 32 305 35 0 35 0 -15.4 0 -14.8 -15.6 03/07/2005 20:20:00 15.7 1.2 18.7 11.8 15.2 1.2 19.1 11.5 0.4 0 0.4 0.4 36 6 33 305 35 0 35 0 -15.3 0.1 -14.8 -15.6 03/07/2005 20:30:00 16.2 1.5 19.5 12.2 15.8 1.5 19.5 11.8 0.4 0 0.4 0.4 35 5 27 305 35 0 35 0 -15.4 0.1 -15 -15.6 03/07/2005 20:40:00 14.6 1.7 19.5 11.1 14.2 1.7 19.1 10.7 0.4 0 0.4 0.4 33 6 34 305 34 0 34 0 -15.3 0.1 -14.8 -15.6 03/07/2005 20:50:00 13.7 1.3 17.2 9.9 13.7 1.3 17.2 10.3 0.4 0 0.4 0.4 35 6 27 305 34 0 34 0 -15.2 0.1 -14.8 -15.6 03/07/2005 21:00:00 14.6 1.7 17.9 10.3 14.2 1.6 17.9 9.9 0.4 0 0.4 0.4 34 6 31 305 34 0 34 0 -15.3 0.1 -14.8 -15.6 03/07/2005 21:10:00 15.8 2 20.6 11.5 15.4 2 20.2 10.7 0.4 0 0.4 0.4 36 6 31 305 34 0 34 0 -15.3 0.2 -14.8 -15.6 03/07/2005 21:20:00 14.6 1.6 18.7 10.7 14.4 1.7 18.7 10.7 0.4 0 0.4 0.4 39 6 43 305 34 0 34 0 -15.3 0.2 -14.8 -15.6 03/07/2005 21:30:00 15.8 1.8 19.9 11.1 15.4 1.9 19.9 11.5 0.4 0 0.4 0.4 37 5 31 305 34 0 34 0 -15.3 0.1 -14.8 -15.6 03/07/2005 21:40:00 16 1.4 19.9 12.2 15.6 1.4 19.9 12.2 0.4 0 0.4 0.4 39 5 48 305 34 0 34 0 -15.3 0.2 -14.8 -15.6 03/07/2005 21:50:00 13.7 1.3 16.8 9.9 13.5 1.3 16.1 10.3 0.4 0 0.4 0.4 31 6 28 305 34 0 34 0 -15.4 0.2 -14.8 -15.8 03/07/2005 22:00:00 14.7 1.3 17.6 11.1 14.6 1.3 17.6 11.5 0.4 0 0.4 0.4 33 5 29 305 34 0 34 0 -15.7 0.2 -15 -15.8 03/07/2005 22:10:00 13.2 1 16.1 10.7 13.1 1 16.4 10.3 0.4 0 0.4 0.4 30 5 24 305 33 0 33 0 -15.8 0.1 -15.2 -16.2 03/07/2005 22:20:00 12.4 1.1 14.9 9.1 12.2 1.2 14.9 9.1 0.4 0 0.4 0.4 27 5 31 305 33 0 33 0 -16.4 0.2 -15.8 -16.9 03/07/2005 22:30:00 12.9 1.3 15.6 9.5 12.7 1.3 16.1 9.5 0.4 0 0.4 0.4 27 6 32 305 32 0 32 0 -16.6 0.2 -16 -16.9 03/07/2005 22:40:00 12.1 1.2 15.3 8.8 11.9 1.2 15.6 7.6 0.4 0 0.4 0.4 26 6 27 305 31 0 31 0 -16.8 0.1 -16.6 -16.9 03/07/2005 22:50:00 12.8 1.3 16.4 9.5 12.6 1.3 16.1 9.5 0.4 0 0.4 0.4 25 5 26 305 30 0 29 0 -16.9 0 -16.7 -16.9 03/07/2005 23:00:00 13.5 1.5 17.6 9.9 13.3 1.5 17.2 9.5 0.4 0 0.4 0.4 28 5 24 305 29 0 29 0 -16.9 0 -16.4 -16.9 03/07/2005 23:10:00 13.1 1.7 17.2 9.5 13 1.7 16.8 9.1 0.4 0 0.4 0.4 29 7 29 305 29 0 29 0 -17.1 0 -16.6 -17.3 03/07/2005 23:20:00 14.2 1.5 17.6 9.9 13.9 1.5 17.2 9.5 0.4 0 0.4 0.4 33 5 33 305 28 0 28 0 -17.1 0 -16.9 -17.3 03/07/2005 23:30:00 13.8 1.2 17.2 11.1 13.6 1.3 16.8 10.7 0.4 0 0.4 0.4 33 5 30 305 28 0 28 0 -17 0 -16.9 -17.3 03/07/2005 23:40:00 13.5 1.3 17.2 10.7 13.2 1.3 16.8 9.9 0.4 0 0.4 0.4 33 6 27 305 28 0 28 0 -17.1 0 -16.9 -17.1 03/07/2005 23:50:00 13.6 1.3 16.4 9.9 13.4 1.2 16.4 10.3 0.4 0 0.4 0.4 32 5 30 305 27 0 28 0 -17 0 -16.9 -17.1 03/08/2005 00:00:00 14.4 1.2 17.6 11.1 14.1 1.2 17.6 10.7 0.4 0 0.4 0.4 27 5 22 305 27 0 27 0 -17.3 0.1 -16.6 -17.5 03/08/2005 00:10:00 13.4 1.2 16.8 9.9 13.3 1.2 16.4 10.3 0.4 0 0.4 0.4 29 6 30 305 27 0 27 0 -17.5 0 -17.1 -17.5 03/08/2005 00:20:00 14.1 1.3 17.6 11.5 13.8 1.3 17.6 10.3 0.4 0 0.4 0.4 30 5 32 305 27 0 27 0 -17.3 0.1 -16.9 -17.5 03/08/2005 00:30:00 13 1.1 16.4 10.3 13 1.2 17.2 10.7 0.4 0 0.4 0.4 28 5 31 305 27 0 27 0 -17.3 0 -16.9 -17.3 03/08/2005 00:40:00 12.3 1 15.6 9.5 12.2 1 15.3 9.9 0.4 0 0.4 0.4 26 5 31 305 27 0 27 0 -17.2 0 -16.9 -17.5 03/08/2005 00:50:00 13.1 1.3 17.2 10.3 13 1.3 16.8 9.9 0.4 0 0.4 0.4 26 6 29 305 27 0 27 0 -17.3 0.1 -16.9 -17.5 03/08/2005 01:00:00 14.2 1.3 17.2 11.5 14 1.4 17.2 11.1 0.4 0 0.4 0.4 24 5 20 305 27 0 27 0 -17.5 0.1 -16.9 -17.7 03/08/2005 01:10:00 13.8 1.3 16.8 10.7 13.7 1.3 17.2 10.3 0.4 0 0.4 0.4 26 5 25 305 26 0 26 0 -17.5 0 -16.9 -17.7 03/08/2005 01:20:00 14.3 1.5 18.3 10.3 13.9 1.5 17.9 10.7 0.4 0 0.4 0.4 28 6 30 305 26 0 26 0 -17.3 0.1 -16.9 -17.5 03/08/2005 01:30:00 13.9 1.3 17.2 11.1 13.6 1.4 16.8 10.7 0.4 0 0.4 0.4 28 6 31 305 26 0 26 0 -17.2 0.1 -16.9 -17.5 03/08/2005 01:40:00 14.3 1.3 18.3 11.1 14.1 1.3 17.9 10.7 0.4 0 0.4 0.4 31 6 31 305 26 0 26 0 -17.3 0.1 -16.9 -17.5 03/08/2005 01:50:00 13.3 1.3 16.8 9.5 13.1 1.4 16.4 9.9 0.4 0 0.4 0.4 26 5 24 305 26 0 27 0 -17.3 0.1 -16.9 -17.5 03/08/2005 02:00:00 13.7 1.5 17.2 10.7 13.5 1.5 17.2 10.7 0.4 0 0.4 0.4 28 5 25 305 27 0 27 0 -17.2 0.1 -16.9 -17.5 03/08/2005 02:10:00 13.2 1.3 16.8 10.3 13 1.3 17.2 9.9 0.4 0 0.4 0.4 28 5 24 305 27 0 27 0 -16.9 0 -16.6 -17.1 03/08/2005 02:20:00 12.8 1.1 15.6 9.1 12.5 1 15.3 9.5 0.4 0 0.4 0.4 29 6 27 305 27 0 27 0 -16.9 0 -16.4 -16.9 03/08/2005 02:30:00 13.7 1.7 17.6 9.9 13.5 1.6 17.2 9.9 0.4 0 0.4 0.4 28 6 31 305 27 0 27 0 -16.8 0.1 -16.4 -16.9 03/08/2005 02:40:00 14.6 1.1 17.2 11.8 14.5 1.1 17.2 11.5 0.4 0 0.4 0.4 34 5 25 305 28 0 28 0 -16.7 0.1 -16.2 -16.9 03/08/2005 02:50:00 14.5 1.4 17.9 10.7 14.2 1.5 17.6 10.7 0.4 0 0.4 0.4 30 5 43 305 28 0 28 0 -16.5 0 -16 -16.7 03/08/2005 03:00:00 13.4 1.3 16.4 9.5 13.2 1.3 16.4 9.5 0.4 0 0.4 0.4 29 6 40 305 28 0 28 0 -16.4 0.1 -16 -16.6 03/08/2005 03:10:00 12.6 0.9 14.9 10.3 12.5 1 14.9 10.3 0.4 0 0.4 0.4 25 5 18 305 28 0 28 0 -16.5 0.1 -16 -16.9 03/08/2005 03:20:00 13.8 1.1 16.1 10.7 13.6 1.2 16.4 10.3 0.4 0 0.4 0.4 24 5 31 305 28 0 28 0 -16.7 0.1 -16.2 -16.9 03/08/2005 03:30:00 13.7 1.3 17.2 9.9 13.5 1.3 16.8 9.9 0.4 0 0.4 0.4 25 6 28 305 28 0 28 0 -16.7 0.1 -16.2 -16.9 03/08/2005 03:40:00 13.3 1 15.3 10.3 13.2 1.1 15.3 10.3 0.4 0 0.4 0.4 24 5 24 305 28 0 28 0 -16.8 0.1 -16.2 -16.9 03/08/2005 03:50:00 12.7 1.4 16.4 9.5 12.6 1.4 16.4 9.9 0.4 0 0.4 0.4 24 5 21 305 28 0 28 0 -16.6 0.1 -16 -16.9 03/08/2005 04:00:00 13.1 1.3 16.1 9.9 13.1 1.2 16.1 9.9 0.4 0 0.4 0.4 25 5 21 305 28 0 28 0 -16.6 0 -16.2 -16.9 03/08/2005 04:10:00 12.7 1.4 16.8 9.9 12.6 1.5 16.4 9.5 0.4 0 0.4 0.4 25 5 28 305 28 0 28 0 -16.6 0 -16 -16.7 03/08/2005 04:20:00 12.7 1.2 16.1 9.9 12.6 1.2 16.1 9.1 0.4 0 0.4 0.4 25 5 22 305 28 0 28 0 -16.6 0 -16 -16.9 03/08/2005 04:30:00 12.3 1 15.3 9.5 12 1 15.3 9.5 0.4 0 0.4 0.4 28 5 24 305 29 0 28 0 -16.4 0 -16 -16.6 03/08/2005 04:40:00 12.4 1.5 15.3 8.8 12.3 1.5 15.3 8.4 0.4 0 0.4 0.4 27 5 24 305 29 0 29 0 -16.3 0 -15.8 -16.6 03/08/2005 04:50:00 11.1 1.5 14.9 7.6 10.9 1.4 14.9 7.2 0.4 0 0.4 0.4 26 5 19 305 29 0 29 0 -16.4 0 -16 -16.6 03/08/2005 05:00:00 12 1 14.1 8.8 11.8 1 14.1 8.4 0.4 0 0.4 0.4 26 6 27 305 29 0 29 0 -16.5 0.1 -16 -16.9 03/08/2005 05:10:00 11.9 1 15.3 9.1 11.7 1 14.5 9.1 0.4 0 0.4 0.4 26 6 25 305 29 0 29 0 -16.8 0.1 -16.4 -17.1 03/08/2005 05:20:00 12.5 1.5 16.1 9.1 12.3 1.3 15.3 9.1 0.4 0 0.4 0.4 27 5 23 305 28 0 28 0 -17 0.1 -16.6 -17.1 03/08/2005 05:30:00 12.2 1 14.5 9.9 11.9 1.1 14.5 9.1 0.4 0 0.4 0.4 27 5 18 305 28 0 28 0 -17 0 -16.6 -17.1 03/08/2005 05:40:00 11.4 1 13.7 9.1 11.1 1 13.7 9.1 0.4 0 0.4 0.4 31 6 33 305 27 0 27 0 -16.9 0 -16.6 -17.1 03/08/2005 05:50:00 10.1 1 13 7.6 9.8 1 13 7.6 0.4 0 0.4 0.4 30 5 25 305 27 0 27 0 -16.9 0 -16.6 -16.9 03/08/2005 06:00:00 11.1 1.2 14.1 8.8 10.9 1.3 13.7 8 0.4 0 0.4 0.4 31 6 38 305 27 0 27 0 -16.9 0 -16.6 -16.9 03/08/2005 06:10:00 11.8 1.5 15.6 8.4 11.6 1.6 16.1 8.4 0.4 0 0.4 0.4 32 6 30 305 27 0 27 0 -17 0.1 -16.6 -17.1 03/08/2005 06:20:00 12.3 1.3 16.1 8.8 12 1.2 15.6 8.4 0.4 0 0.4 0.4 34 6 35 305 27 0 27 0 -17.1 0 -16.6 -17.3 03/08/2005 06:30:00 13.5 1.5 16.4 10.3 13.2 1.5 16.8 9.5 0.4 0 0.4 0.4 32 6 27 305 27 0 27 0 -17 0 -16.6 -17.3 03/08/2005 06:40:00 12 1.2 15.6 9.1 11.5 1.2 15.3 9.1 0.4 0 0.4 0.4 32 6 35 305 26 0 27 0 -17.2 0.1 -16.9 -17.5 03/08/2005 06:50:00 10.9 1.2 14.1 8 10.7 1.2 14.5 7.6 0.4 0 0.4 0.4 33 6 27 305 26 0 26 0 -17.3 0.1 -16.9 -17.5 03/08/2005 07:00:00 11.7 1.3 14.9 8.4 11.4 1.3 14.5 8.8 0.4 0 0.4 0.4 30 7 33 305 26 0 26 0 -17.3 0.1 -16.9 -17.5 03/08/2005 07:10:00 11.3 1.2 14.5 8.4 11.1 1.3 14.5 8.4 0.4 0 0.4 0.4 34 6 28 305 26 0 26 0 -17.3 0.1 -16.9 -17.5 03/08/2005 07:20:00 11.9 1.2 14.5 8.8 11.7 1.2 14.5 8.4 0.4 0 0.4 0.4 30 6 36 305 26 0 26 0 -17.4 0 -16.9 -17.5 03/08/2005 07:30:00 11.7 1.2 15.3 9.1 11.4 1.2 14.1 9.1 0.4 0 0.4 0.4 28 5 21 305 25 0 26 0 -17.5 0 -16.9 -17.7 03/08/2005 07:40:00 12.6 1.2 15.6 9.5 12.3 1.1 15.3 9.9 0.4 0 0.4 0.4 27 5 24 305 25 0 25 0 -17.5 0 -16.9 -17.7 03/08/2005 07:50:00 12.2 1.2 15.3 9.1 11.9 1.2 14.9 8.4 0.4 0 0.4 0.4 28 5 22 305 25 0 25 0 -17.5 0 -16.9 -17.5 03/08/2005 08:00:00 11.9 1.3 16.1 9.1 11.8 1.3 16.1 9.1 0.4 0 0.4 0.4 29 5 26 305 25 0 25 0 -17.5 0 -16.9 -17.5 03/08/2005 08:10:00 12 1.2 15.3 8.8 11.8 1.2 15.3 8.4 0.4 0 0.4 0.4 30 6 31 305 25 0 25 0 -17.4 0 -16.9 -17.5 03/08/2005 08:20:00 12.5 1.8 17.6 8.8 12.2 1.8 17.2 8.4 0.4 0 0.4 0.4 27 6 27 305 25 0 25 0 -17.5 0 -17.1 -17.7 03/08/2005 08:30:00 12.7 1.2 16.1 9.1 12.5 1.2 15.6 9.1 0.4 0 0.4 0.4 30 6 31 305 25 0 25 0 -17.5 0 -17.1 -17.9 03/08/2005 08:40:00 12.6 1.2 15.6 9.5 12.3 1.3 16.1 9.5 0.4 0 0.4 0.4 26 5 31 305 25 0 25 0 -17.6 0 -17.3 -17.9 03/08/2005 08:50:00 12.3 1.3 16.8 9.9 12.1 1.3 16.1 8.4 0.4 0 0.4 0.4 27 5 32 305 25 0 25 0 -17.5 0 -17.1 -17.7 03/08/2005 09:00:00 12.9 1.5 16.4 9.9 12.6 1.5 16.8 9.1 0.4 0 0.4 0.4 30 6 33 305 25 0 25 0 -17.6 0 -17.1 -17.9 03/08/2005 09:10:00 12.6 1.5 16.4 9.5 12.3 1.6 15.6 8.8 0.4 0 0.4 0.4 27 6 25 305 25 0 25 0 -17.7 0.2 -17.1 -18.1 03/08/2005 09:20:00 13.3 1.1 16.1 9.5 13.2 1.1 15.6 9.9 0.4 0 0.4 0.4 27 6 35 305 25 0 25 0 -18 0 -17.5 -18.1 03/08/2005 09:30:00 12.9 1.1 15.3 9.9 12.7 1.1 15.3 9.5 0.4 0 0.4 0.4 28 6 29 305 25 0 25 0 -17.8 0.1 -17.3 -18.1 03/08/2005 09:40:00 13.3 1.3 16.8 10.3 13.1 1.2 16.8 9.9 0.4 0 0.4 0.4 26 6 17 305 25 0 25 0 -17.5 0 -16.9 -17.7 03/08/2005 09:50:00 14.5 1.7 17.9 10.7 14.2 1.7 18.3 10.7 0.4 0 0.4 0.4 26 5 24 305 25 0 25 0 -17.7 0 -17.3 -17.9 03/08/2005 10:00:00 14.1 1.7 17.9 9.9 13.8 1.6 18.3 9.1 0.4 0 0.4 0.4 27 6 18 305 25 0 25 0 -17.6 0.1 -17.1 -17.7 03/08/2005 10:10:00 14.3 1.5 17.9 10.7 14 1.5 18.3 9.9 0.4 0 0.4 0.4 29 5 27 305 26 0 26 0 -17.7 0.1 -17.1 -17.9 03/08/2005 10:20:00 13.5 1.6 17.2 9.9 13.4 1.6 17.6 9.9 0.4 0 0.4 0.4 25 6 27 305 26 0 26 0 -17.7 0 -17.3 -17.9 03/08/2005 10:30:00 14.3 1.4 17.9 10.3 14.2 1.3 17.6 10.7 0.4 0 0.4 0.4 22 5 18 305 26 0 26 0 -17.6 0 -17.1 -17.9 03/08/2005 10:40:00 13.9 1.2 17.2 9.5 13.8 1.3 16.8 10.3 0.4 0 0.4 0.4 22 6 30 305 26 0 26 0 -17.4 0.1 -16.9 -17.5 03/08/2005 10:50:00 13.5 1.3 16.8 9.9 13.3 1.4 17.6 9.5 0.4 0 0.4 0.4 23 6 17 305 27 0 27 0 -17.3 0.1 -16.9 -17.5 03/08/2005 11:00:00 13.7 1.7 17.6 9.1 13.6 1.7 17.2 8.8 0.4 0 0.4 0.4 24 6 23 305 27 0 27 0 -17.2 0.1 -16.6 -17.5 03/08/2005 11:10:00 14 1.5 17.6 10.3 13.7 1.4 17.6 9.9 0.4 0 0.4 0.4 24 6 22 305 28 0 27 0 -17.2 0.1 -16.7 -17.5 03/08/2005 11:20:00 14.1 1.2 16.8 10.7 13.9 1.2 16.8 11.1 0.4 0 0.4 0.4 23 6 19 305 29 0 29 0 -17.5 0.1 -16.9 -17.7 03/08/2005 11:30:00 13.8 1.3 17.2 9.5 13.7 1.3 16.8 9.9 0.4 0 0.4 0.4 22 6 19 305 29 0 29 0 -17.6 0.1 -17.1 -17.9 03/08/2005 11:40:00 14.1 1.3 17.2 10.3 13.8 1.3 17.6 10.7 0.4 0 0.4 0.4 23 6 29 305 29 0 29 0 -17.7 0.1 -17.3 -17.9 03/08/2005 11:50:00 12.7 1.5 16.4 8.8 12.7 1.5 17.2 8.8 0.4 0 0.4 0.4 21 6 29 305 29 0 29 0 -17.7 0.1 -17.1 -17.9 03/08/2005 12:00:00 14.1 1.4 17.2 10.7 14 1.5 16.8 9.9 0.4 0 0.4 0.4 20 5 20 305 29 0 29 0 -17.7 0.1 -17.3 -17.9 03/08/2005 12:10:00 13.9 1.3 16.8 10.7 13.7 1.3 16.8 10.3 0.4 0 0.4 0.4 20 6 23 305 29 0 28 0 -17.8 0.1 -17.3 -18.1 03/08/2005 12:20:00 13.5 1.3 16.4 10.3 13.5 1.3 16.4 10.3 0.4 0 0.4 0.4 18 5 13 305 28 0 28 0 -17.7 0 -17.1 -17.9 03/08/2005 12:30:00 11.9 1.1 14.5 9.1 11.7 1.1 14.9 9.1 0.4 0 0.4 0.4 17 5 14 305 29 0 28 0 -17.5 0 -16.9 -17.7 03/08/2005 12:40:00 12.5 1 15.3 10.3 12.6 1 15.6 9.9 0.4 0 0.4 0.4 17 5 12 305 29 0 29 0 -17.5 0.1 -16.9 -17.7 03/08/2005 12:50:00 12.5 1.1 14.9 9.5 12.5 1.2 14.9 9.1 0.4 0 0.4 0.4 17 5 12 305 29 0 29 0 -17.5 0.1 -16.9 -17.5 03/08/2005 13:00:00 12.5 1.1 14.9 9.5 12.5 1.2 14.5 9.5 0.4 0 0.4 0.4 18 5 17 305 30 0 29 0 -17.3 0.1 -16.9 -17.5 03/08/2005 13:10:00 11.8 1 14.1 8.8 11.6 1.1 14.5 8 0.4 0 0.4 0.4 20 5 18 305 30 0 31 0 -16.9 0.1 -16.2 -17.3 03/08/2005 13:20:00 12.4 1.2 14.9 9.5 12.4 1.2 14.5 8.8 0.4 0 0.4 0.4 17 5 18 305 31 0 31 0 -16.8 0.1 -16.2 -16.9 03/08/2005 13:30:00 12.2 1.1 14.9 9.9 12 1.1 14.5 9.5 0.4 0 0.4 0.4 16 5 8 305 31 0 32 0 -16.8 0.1 -16.4 -16.9 03/08/2005 13:40:00 12.1 0.9 13.7 9.1 12 1 14.1 8.4 0.4 0 0.4 0.4 16 5 19 305 32 0 32 0 -16.9 0.1 -16.4 -17.1 03/08/2005 13:50:00 12.9 0.9 15.3 10.3 12.8 1 15.3 10.3 0.4 0 0.4 0.4 17 4 18 305 32 0 32 0 -16.8 0.1 -16.2 -16.9 03/08/2005 14:00:00 12.4 1.3 14.9 8.4 12.4 1.4 15.3 8.8 0.4 0 0.4 0.4 17 5 18 305 32 0 32 0 -16.7 0.2 -16 -16.9 03/08/2005 14:10:00 12.8 1.3 16.1 9.5 12.7 1.3 15.6 9.1 0.4 0 0.4 0.4 16 5 18 305 33 0 33 0 -16.5 0.1 -16 -16.7 03/08/2005 14:20:00 11.7 1.1 14.1 8.8 11.6 1.2 14.5 9.1 0.4 0 0.4 0.4 19 5 19 305 33 0 33 0 -16.3 0.1 -15.6 -16.6 03/08/2005 14:30:00 12.3 1.2 16.4 8.8 12.2 1.2 16.4 9.1 0.4 0 0.4 0.4 25 6 27 305 34 0 34 0 -16 0.1 -15.6 -16.4 03/08/2005 14:40:00 13.4 1.4 16.4 9.5 13.1 1.4 16.1 8.8 0.4 0 0.4 0.4 25 5 20 305 35 0 35 0 -15.9 0.1 -15.4 -16.2 03/08/2005 14:50:00 13.2 1.5 17.6 9.9 13.1 1.5 17.6 9.1 0.4 0 0.4 0.4 21 5 21 305 36 0 36 0 -15.8 0.1 -15.2 -16 03/08/2005 15:00:00 13 1.5 17.2 9.5 12.8 1.6 17.2 8.8 0.4 0 0.4 0.4 21 6 19 305 37 0 37 0 -15.8 0.1 -15.2 -16 03/08/2005 15:10:00 11.8 1.6 16.1 8.8 11.6 1.7 16.1 8 0.4 0 0.4 0.4 20 6 20 305 38 0 38 0 -15.8 0.2 -15 -16 03/08/2005 15:20:00 13.5 1.7 17.9 9.5 13.3 1.7 17.9 9.5 0.4 0 0.4 0.4 24 6 22 305 39 0 40 0 -15.7 0.2 -15 -16 03/08/2005 15:30:00 14.3 1.4 18.7 11.1 14 1.4 18.3 10.7 0.4 0 0.4 0.4 27 6 31 305 40 0 40 0 -15.6 0.2 -15 -15.8 03/08/2005 15:40:00 15.8 1.7 19.9 11.1 15.5 1.7 19.5 10.7 0.4 0 0.4 0.4 25 6 24 305 41 0 41 0 -15.5 0.2 -15 -15.8 03/08/2005 15:50:00 15.7 1.7 19.9 10.7 15.3 1.7 19.5 10.7 0.4 0 0.4 0.4 29 6 33 305 41 0 41 0 -15.8 0.2 -15.2 -16 03/08/2005 16:00:00 15 2.1 19.1 10.3 14.7 2.1 19.1 9.9 0.4 0 0.4 0.4 30 6 26 305 42 0 42 0 -15.8 0.2 -15 -16 03/08/2005 16:10:00 15.9 1.6 20.2 12.2 15.7 1.6 19.5 11.8 0.4 0 0.4 0.4 26 6 18 305 42 0 42 0 -15.7 0.2 -15.2 -16 03/08/2005 16:20:00 14.6 1.5 18.7 11.5 14.3 1.5 17.9 11.1 0.4 0 0.4 0.4 25 6 22 305 42 0 42 0 -15.7 0.2 -15 -16 03/08/2005 16:30:00 15.2 1.4 19.1 11.5 14.9 1.3 18.3 11.8 0.4 0 0.4 0.4 28 5 27 305 43 0 43 0 -15.8 0.1 -15.2 -16 03/08/2005 16:40:00 15.4 1.5 19.1 11.5 15.1 1.5 19.1 11.1 0.4 0 0.4 0.4 26 5 31 305 43 0 43 0 -15.9 0.2 -15.4 -16.2 03/08/2005 16:50:00 15 1.7 18.3 9.9 14.8 1.8 18.3 9.9 0.4 0 0.4 0.4 25 7 17 305 43 0 43 0 -16.2 0.2 -15.6 -16.6 03/08/2005 17:00:00 14.5 1.9 18.7 10.3 14.2 1.8 18.7 9.9 0.4 0 0.4 0.4 23 6 30 305 43 0 43 0 -16.5 0.2 -15.8 -16.9 03/08/2005 17:10:00 15.2 1.6 19.1 11.1 15 1.7 19.1 11.5 0.4 0 0.4 0.4 19 5 18 305 42 0 41 0 -17 0.1 -16.4 -17.3 03/08/2005 17:20:00 14.8 1.7 19.1 10.3 14.6 1.6 18.7 9.9 0.4 0 0.4 0.4 23 6 19 305 40 1 40 0 -17.4 0.1 -16.9 -17.7 03/08/2005 17:30:00 14.5 1.7 18.7 10.7 14.3 1.7 18.3 10.3 0.4 0 0.4 0.4 22 7 11 305 38 0 39 0 -17.7 0.1 -17.1 -18.1 03/08/2005 17:40:00 15.7 1.9 19.9 11.5 15.4 1.8 19.9 11.5 0.4 0 0.4 0.4 23 5 25 305 37 0 37 0 -18.1 0.1 -17.5 -18.4 03/08/2005 17:50:00 15.2 1.4 18.3 11.8 15 1.3 17.9 11.5 0.4 0 0.4 0.4 20 8 25 305 35 1 36 0 -18.2 0.1 -17.7 -18.4 03/08/2005 18:00:00 15.3 1.9 19.1 10.3 15 1.8 19.5 10.7 0.4 0 0.4 0.4 12 5 13 305 31 1 30 0 -18.5 0 -18.1 -18.8 03/08/2005 18:10:00 14.8 1.7 19.1 10.3 14.5 1.7 18.7 9.9 0.4 0 0.4 0.4 13 6 10 305 29 1 29 0 -18.4 0.1 -18.1 -18.6 03/08/2005 18:20:00 13.7 1.7 17.9 9.1 13.7 1.7 18.3 8.8 0.4 0 0.4 0.4 10 7 11 305 27 0 28 0 -18.4 0.1 -18.1 -18.4 03/08/2005 18:30:00 14.7 1.7 19.5 10.3 14.5 1.7 18.7 9.9 0.4 0 0.4 0.4 11 5 12 305 28 0 27 0 -18.4 0.1 -18.1 -18.4 03/08/2005 18:40:00 14.5 1.3 17.6 10.7 14.5 1.3 17.6 10.7 0.4 0 0.4 0.4 15 5 17 305 27 0 27 0 -18.4 0.1 -18.1 -18.4 03/08/2005 18:50:00 13.9 1.5 17.6 9.9 13.7 1.5 17.2 9.5 0.4 0 0.4 0.4 12 6 13 305 27 0 27 0 -18.3 0 -18.1 -18.4 03/08/2005 19:00:00 14.9 1.4 18.3 11.1 14.7 1.4 18.3 11.1 0.4 0 0.4 0.4 11 5 5 305 27 0 26 0 -18.3 0.1 -18.1 -18.4 03/08/2005 19:10:00 13.5 1.2 16.4 10.3 13.5 1.2 16.4 10.3 0.4 0 0.4 0.4 11 5 8 305 26 0 26 0 -18.2 0.1 -17.9 -18.4 03/08/2005 19:20:00 14.1 1.6 18.3 10.3 14.1 1.7 18.7 10.7 0.4 0 0.4 0.4 13 6 9 305 25 0 25 0 -18.3 0.1 -18.1 -18.4 03/08/2005 19:30:00 14.5 1.7 17.9 9.9 14.2 1.7 17.9 9.9 0.4 0 0.4 0.4 13 5 10 305 25 0 25 0 -18.6 0 -18.2 -18.8 03/08/2005 19:40:00 15.2 1.5 18.7 10.7 15 1.5 18.7 10.3 0.4 0 0.4 0.4 14 5 18 305 24 0 24 0 -18.8 0.1 -18.4 -19 03/08/2005 19:50:00 13.4 1.7 17.9 9.1 13.4 1.7 17.6 8.8 0.4 0 0.4 0.4 17 5 17 305 23 0 23 0 -19.1 0.1 -18.8 -19.3 03/08/2005 20:00:00 12.8 1.5 16.4 9.1 12.6 1.4 16.1 9.1 0.4 0 0.4 0.4 10 6 5 305 22 0 22 0 -19.2 0.1 -19 -19.5 03/08/2005 20:10:00 13.3 1.5 16.8 10.3 13.2 1.5 17.2 9.1 0.4 0 0.4 0.4 11 6 3 305 21 0 21 0 -19.5 0 -19.2 -19.5 03/08/2005 20:20:00 13.2 1.2 16.8 9.5 12.9 1.2 16.4 9.5 0.4 0 0.4 0.4 14 6 19 305 21 0 21 0 -19.5 0 -19.2 -19.5 03/08/2005 20:30:00 12.1 1.3 15.6 8.4 11.9 1.4 16.1 8.4 0.4 0 0.4 0.4 8 6 9 305 21 0 20 0 -19.5 0 -19.3 -19.5 03/08/2005 20:40:00 11.7 1.2 15.6 8.4 11.6 1.2 15.3 8.4 0.4 0 0.4 0.4 8 5 1 305 20 0 20 0 -19.2 0 -19 -19.5 03/08/2005 20:50:00 12.5 1.5 16.8 9.1 12.4 1.5 17.2 8.8 0.4 0 0.4 0.4 14 6 12 305 20 0 20 0 -19 0.2 -18.4 -19.5 03/08/2005 21:00:00 15 2.2 19.9 10.7 14.8 2.2 19.5 10.3 0.4 0 0.4 0.4 20 6 15 305 21 0 21 0 -18.6 0 -18.4 -18.8 03/08/2005 21:10:00 15.1 1.9 18.7 10.7 14.8 1.9 18.3 10.3 0.4 0 0.4 0.4 19 6 16 305 21 0 21 0 -18.7 0.1 -18.4 -19 03/08/2005 21:20:00 13.2 1.7 17.9 9.9 13.1 1.7 17.9 9.5 0.4 0 0.4 0.4 18 7 18 305 21 0 21 0 -18.9 0.1 -18.4 -19 03/08/2005 21:30:00 14.1 2.1 19.1 9.1 14 2.3 19.5 9.1 0.4 0 0.4 0.4 16 5 16 305 21 0 21 0 -19 0 -18.6 -19 03/08/2005 21:40:00 15.4 1.6 18.7 10.7 15.2 1.6 18.3 10.7 0.4 0 0.4 0.4 20 6 29 305 21 0 21 0 -19 0 -18.6 -19.2 03/08/2005 21:50:00 14.9 1.8 19.1 9.9 14.7 1.8 19.1 10.7 0.4 0 0.4 0.4 19 6 25 305 21 0 21 0 -19.1 0 -18.6 -19.3 03/08/2005 22:00:00 14.7 1.4 17.9 11.1 14.5 1.5 17.9 10.3 0.4 0 0.4 0.4 9 5 9 305 21 0 20 0 -19.5 0.1 -19 -19.5 03/08/2005 22:10:00 14.3 1.4 17.9 11.5 14.3 1.3 17.6 11.5 0.4 0 0.4 0.4 13 6 7 305 20 0 21 0 -19.4 0.1 -19 -19.5 03/08/2005 22:20:00 14.7 1.4 17.9 11.5 14.7 1.3 17.9 11.5 0.4 0 0.4 0.4 13 5 11 305 20 0 20 0 -19.3 0 -19 -19.5 03/08/2005 22:30:00 14.8 1.3 17.9 11.1 14.7 1.5 17.9 11.5 0.4 0 0.4 0.4 15 5 15 305 20 0 20 0 -19.2 0 -19 -19.5 03/08/2005 22:40:00 14.2 2 19.1 9.9 14 1.9 19.1 9.5 0.4 0 0.4 0.4 15 6 12 305 20 0 20 0 -19.2 0 -19 -19.5 03/08/2005 22:50:00 14.8 1.4 18.7 11.1 14.5 1.3 18.7 11.1 0.4 0 0.4 0.4 14 5 14 305 20 0 20 0 -19.3 0 -19 -19.5 03/08/2005 23:00:00 13.8 1.7 17.6 9.1 13.5 1.8 17.2 9.1 0.4 0 0.4 0.4 15 6 8 305 20 0 20 0 -19.4 0 -19 -19.5 03/08/2005 23:10:00 14.5 1.7 19.1 11.5 14.4 1.6 18.3 11.5 0.4 0 0.4 0.4 20 6 29 305 20 0 20 0 -19.4 0 -19 -19.5 03/08/2005 23:20:00 15.2 1.6 18.7 10.7 15 1.6 18.7 9.9 0.4 0 0.4 0.4 20 5 13 305 20 0 20 0 -19.2 0.1 -19 -19.5 03/08/2005 23:30:00 15.9 1.7 19.5 11.1 15.6 1.7 19.5 11.1 0.4 0 0.4 0.4 20 5 12 305 20 0 20 0 -19.3 0.1 -19 -19.5 03/08/2005 23:40:00 17.1 1.4 21.8 13.3 16.6 1.6 21.4 13.3 0.4 0 0.4 0.4 19 6 25 305 20 0 20 0 -19.5 0 -19.2 -19.5 03/08/2005 23:50:00 16.1 1.5 19.5 11.8 15.8 1.4 19.5 11.8 0.4 0 0.4 0.4 18 5 22 305 20 0 20 0 -19.6 0 -19.3 -19.7 03/09/2005 00:00:00 15.7 1.7 19.9 11.8 15.5 1.7 19.9 11.5 0.4 0 0.4 0.4 17 5 13 305 20 0 20 0 -19.5 0 -19 -19.5 03/09/2005 00:10:00 15.5 1.7 19.1 10.7 15.4 1.7 19.1 11.5 0.4 0 0.4 0.4 18 6 15 305 20 0 20 0 -19.7 0.1 -19.3 -19.9 03/09/2005 00:20:00 14.6 1.7 18.7 9.9 14.4 1.8 18.7 9.9 0.4 0 0.4 0.4 17 5 14 305 19 0 19 0 -19.8 0.1 -19.5 -20.1 03/09/2005 00:30:00 13.1 1.5 16.8 8.4 13 1.5 16.8 9.5 0.4 0 0.4 0.4 16 5 12 305 19 0 19 0 -19.7 0.1 -19.5 -20.1 03/09/2005 00:40:00 14.6 1.5 18.3 10.3 14.4 1.5 17.6 10.3 0.4 0 0.4 0.4 16 5 12 305 19 0 19 0 -20 0 -19.7 -20.1 03/09/2005 00:50:00 13 1.4 16.4 9.1 12.8 1.4 16.4 9.5 0.4 0 0.4 0.4 18 6 16 305 19 0 19 0 -19.7 0 -19.5 -20.1 03/09/2005 01:00:00 13.2 1.7 16.4 9.1 13.1 1.7 17.6 8.8 0.4 0 0.4 0.4 24 7 32 305 19 0 19 0 -19.7 0 -19.3 -19.9 03/09/2005 01:10:00 13.8 1.7 17.9 10.3 13.5 1.7 17.9 10.3 0.4 0 0.4 0.4 21 7 22 305 19 0 19 0 -19.8 0 -19.5 -20.1 03/09/2005 01:20:00 14.7 1.5 18.7 10.7 14.5 1.5 17.9 11.1 0.4 0 0.4 0.4 22 5 22 305 19 0 19 0 -19.7 0 -19.5 -19.9 03/09/2005 01:30:00 13.3 1.8 17.6 8.4 13.2 1.9 17.6 8.4 0.4 0 0.4 0.4 20 7 18 305 19 0 19 0 -19.7 0 -19.5 -19.9 03/09/2005 01:40:00 12.1 1.5 16.1 8 11.9 1.5 16.1 8 0.4 0 0.4 0.4 23 6 16 305 19 0 19 0 -19.8 0 -19.5 -19.9 03/09/2005 01:50:00 13.3 1.7 17.6 8.8 13.2 1.8 18.3 9.5 0.4 0 0.4 0.4 16 6 9 305 19 0 19 0 -20 0.1 -19.5 -20.1 03/09/2005 02:00:00 13.4 2.3 18.3 8.4 13.3 2.3 18.3 8 0.4 0 0.4 0.4 15 6 11 305 19 0 19 0 -20.2 0 -19.9 -20.2 03/09/2005 02:10:00 11.3 1.2 14.1 8 11 1.2 14.5 7.6 0.4 0 0.4 0.4 19 6 22 305 19 0 19 0 -20.2 0 -19.9 -20.2 03/09/2005 02:20:00 11.6 1.3 16.1 8.4 11.4 1.2 16.1 8.4 0.4 0 0.4 0.4 16 6 23 305 18 0 18 0 -20.2 0 -19.9 -20.1 03/09/2005 02:30:00 10.9 2 16.1 7.2 10.7 2 15.3 6.8 0.4 0 0.4 0.4 18 7 28 305 18 0 18 0 -20 0 -19.9 -20.1 03/09/2005 02:40:00 11.9 1.7 16.8 7.6 11.7 1.7 16.8 7.6 0.4 0 0.4 0.4 19 6 20 305 18 0 18 0 -20.1 0 -19.7 -20.2 03/09/2005 02:50:00 12.2 1.3 15.6 8.8 12.2 1.4 15.6 8 0.4 0 0.4 0.4 17 7 13 305 18 0 18 0 -20.2 0 -20.1 -20.2 03/09/2005 03:00:00 11.3 1.2 14.5 8.4 11.3 1.2 14.1 8.4 0.4 0 0.4 0.4 21 5 19 305 18 0 18 0 -20.2 0 -20.1 -20.2 03/09/2005 03:10:00 11.3 1.4 14.9 7.2 11.1 1.3 14.9 7.6 0.4 0 0.4 0.4 19 6 20 305 18 0 18 0 -20.3 0 -20.1 -20.6 03/09/2005 03:20:00 10.2 1.3 13.7 7.2 10 1.3 13.7 7.2 0.4 0 0.4 0.4 20 7 20 305 18 0 18 0 -20.5 0.1 -20.2 -20.8 03/09/2005 03:30:00 10.3 1.1 13.3 7.6 10.3 1 13 8 0.4 0 0.4 0.4 18 7 22 305 18 0 18 0 -20.7 0 -20.6 -20.8 03/09/2005 03:40:00 13.5 1.3 16.4 9.5 13.5 1.4 16.4 9.9 0.4 0 0.4 0.4 13 4 12 305 18 0 18 0 -20.8 0 -20.8 -21.1 03/09/2005 03:50:00 11 1.3 14.1 7.6 10.9 1.3 14.1 7.2 0.4 0 0.4 0.4 19 5 21 305 17 0 18 0 -20.9 0 -20.8 -21.1 03/09/2005 04:00:00 12.7 1.7 16.1 8.4 12.6 1.8 16.4 8.4 0.4 0 0.4 0.4 17 6 18 305 17 0 17 0 -20.7 0 -20.4 -21 03/09/2005 04:10:00 11.2 1.5 14.1 8 11 1.5 14.5 8 0.4 0 0.4 0.4 19 6 10 305 17 0 17 0 -20.6 0 -20.4 -20.8 03/09/2005 04:20:00 11 1.5 14.5 6.8 11 1.5 14.9 7.2 0.4 0 0.4 0.4 22 5 16 305 17 0 17 0 -20.6 0 -20.4 -20.8 03/09/2005 04:30:00 11.1 1.7 14.5 6.5 10.9 1.7 14.5 6.8 0.4 0 0.4 0.4 21 7 21 305 17 0 17 0 -20.7 0 -20.4 -21 03/09/2005 04:40:00 13.8 1.4 17.6 9.1 13.3 1.3 16.8 9.9 0.4 0 0.4 0.4 21 6 19 305 17 0 17 0 -21 0 -20.8 -21.1 03/09/2005 04:50:00 13.4 1.5 17.2 9.9 13.1 1.5 17.2 9.9 0.4 0 0.4 0.4 23 6 35 305 17 0 17 0 -21 0 -20.8 -21.1 03/09/2005 05:00:00 14 1.3 17.6 11.1 13.9 1.4 17.6 10.3 0.4 0 0.4 0.4 22 5 20 305 17 0 17 0 -21 0 -20.8 -21.3 03/09/2005 05:10:00 13.7 1.1 16.1 9.9 13.5 1.2 15.6 9.9 0.4 0 0.4 0.4 25 5 27 305 17 0 17 0 -21 0 -20.8 -21.1 03/09/2005 05:20:00 12.2 1.1 15.3 9.9 12.1 1.1 15.6 9.5 0.4 0 0.4 0.4 27 6 25 305 17 0 16 0 -21 0 -20.8 -21.3 03/09/2005 05:30:00 11.5 1.3 15.6 8.4 11.4 1.4 14.9 8 0.4 0 0.4 0.4 22 6 18 305 17 0 16 0 -21 0 -20.8 -21.1 03/09/2005 05:40:00 11.3 1.1 14.9 9.1 11.2 1.1 14.9 8.4 0.4 0 0.4 0.4 19 5 20 305 16 0 16 0 -20.9 0.1 -20.8 -21.1 03/09/2005 05:50:00 11.2 1.5 14.9 7.6 11 1.5 15.3 7.6 0.4 0 0.4 0.4 18 6 19 305 17 0 16 0 -20.8 0 -20.6 -21 03/09/2005 06:00:00 9.3 1.6 13 5.3 9.1 1.6 12.2 5.7 0.4 0 0.4 0.4 19 8 30 305 17 0 16 0 -20.7 0 -20.4 -21 03/09/2005 06:10:00 9.4 1.7 13.7 5.3 9.2 1.7 13.3 5.3 0.4 0 0.4 0.4 21 7 20 305 17 0 16 0 -20.7 0 -20.8 -21 03/09/2005 06:20:00 11.2 1.8 15.6 8 11 1.7 15.6 6.8 0.4 0 0.4 0.4 20 6 19 305 17 0 17 0 -20.7 0 -20.6 -21 03/09/2005 06:30:00 11.5 1.3 14.9 8.8 11.2 1.4 14.5 8.4 0.4 0 0.4 0.4 20 6 24 305 17 0 17 0 -20.7 0 -20.6 -20.8 03/09/2005 06:40:00 10.6 1.2 13.3 7.2 10.5 1.3 13 7.2 0.4 0 0.4 0.4 20 7 15 305 17 0 17 0 -20.6 0 -20.4 -20.8 03/09/2005 06:50:00 9.7 1.5 13.3 6.1 9.6 1.5 13.3 6.5 0.4 0 0.4 0.4 19 6 13 305 17 0 17 0 -20.6 0 -20.4 -20.8 03/09/2005 07:00:00 10.7 1.1 13 6.8 10.7 1.1 13.3 6.8 0.4 0 0.4 0.4 13 6 21 305 17 0 17 0 -20.7 0 -20.6 -20.8 03/09/2005 07:10:00 9 1.5 13 6.5 9 1.5 13 5.7 0.4 0 0.4 0.4 18 6 18 305 17 0 17 0 -20.7 0 -20.6 -20.8 03/09/2005 07:20:00 10.5 1.1 13.3 7.6 10.4 1.1 13.3 7.6 0.4 0 0.4 0.4 20 6 13 305 17 0 17 0 -20.6 0 -20.4 -20.8 03/09/2005 07:30:00 8.4 1.5 12.6 5.3 8.2 1.5 12.6 5.3 0.4 0 0.4 0.4 21 6 21 305 17 0 17 0 -20.5 0 -20.2 -20.8 03/09/2005 07:40:00 8.5 1 10.7 6.1 8.3 1.1 10.7 4.9 0.4 0 0.4 0.4 14 6 9 305 17 0 17 0 -20.4 0 -20.1 -20.6 03/09/2005 07:50:00 8.3 1 10.3 5.7 8.2 0.9 11.1 6.1 0.4 0 0.4 0.4 12 5 13 305 17 0 17 0 -20.4 0 -20.1 -20.6 03/09/2005 08:00:00 9.9 1 12.6 7.6 9.8 1 13 7.2 0.4 0 0.4 0.4 16 5 22 305 17 0 17 0 -20.2 0 -20.1 -20.4 03/09/2005 08:10:00 10.7 1.1 14.1 8 10.4 1.2 13.7 8 0.4 0 0.4 0.4 22 6 15 305 17 0 17 0 -20.2 0 -20.1 -20.4 03/09/2005 08:20:00 9.9 1 12.2 7.6 9.7 1 12.2 7.6 0.4 0 0.4 0.4 26 6 26 305 17 0 17 0 -20.2 0 -19.9 -20.2 03/09/2005 08:30:00 10.4 1 12.2 7.2 10.3 1 12.6 7.6 0.4 0 0.4 0.4 28 5 14 305 17 0 17 0 -20.2 0 -20.1 -20.2 03/09/2005 08:40:00 10.6 1.2 14.1 8 10.4 1.3 13.7 7.6 0.4 0 0.4 0.4 24 6 20 305 17 0 17 0 -20.4 0 -20.1 -20.6 03/09/2005 08:50:00 10.5 1.1 13.7 7.6 10.4 1.1 13.7 7.6 0.4 0 0.4 0.4 26 5 22 305 17 0 17 0 -20.3 0 -20.1 -20.6 03/09/2005 09:00:00 7.9 1.1 10.7 5.7 7.7 1 10.3 5.7 0.4 0 0.4 0.4 24 6 26 305 17 0 17 0 -20.3 0 -20.1 -20.6 03/09/2005 09:10:00 8 1 11.5 4.9 7.9 1.1 10.7 4.9 0.4 0 0.4 0.4 26 6 33 305 17 0 17 0 -20.2 0 -19.9 -20.4 03/09/2005 09:20:00 8.5 1.2 11.1 5.7 8.4 1.2 10.7 5.3 0.4 0 0.4 0.4 20 8 18 305 17 0 18 0 -20.1 0 -19.9 -20.1 03/09/2005 09:30:00 8 1.2 11.1 5.3 7.9 1.3 11.8 4.9 0.4 0 0.4 0.4 18 6 25 305 18 0 18 0 -19.9 0 -19.5 -20.1 03/09/2005 09:40:00 8.5 0.9 10.7 6.1 8.5 0.9 11.1 6.1 0.4 0 0.4 0.4 23 6 29 305 18 0 18 0 -19.6 0.1 -19.3 -19.9 03/09/2005 09:50:00 8.6 1.4 12.2 5.3 8.5 1.5 12.2 5.3 0.4 0 0.4 0.4 21 8 16 305 18 0 18 0 -19.6 0 -19.2 -19.7 03/09/2005 10:00:00 7.9 1.2 11.5 4.9 7.8 1.2 11.5 4.9 0.4 0 0.4 0.4 26 8 19 305 19 0 19 0 -19.5 0.1 -19.2 -19.7 03/09/2005 10:10:00 8.6 1 10.7 6.5 8.5 0.8 10.7 6.8 0.4 0 0.4 0.4 26 6 30 305 19 0 19 0 -19.3 0.1 -19 -19.5 03/09/2005 10:20:00 8.8 0.9 11.5 6.1 8.8 1 11.8 6.1 0.4 0 0.4 0.4 27 7 21 305 19 0 20 0 -18.9 0.1 -18.4 -19.2 03/09/2005 10:30:00 8.9 1.1 11.5 6.1 8.7 1.1 11.5 5.3 0.4 0 0.4 0.4 27 8 18 305 20 0 20 0 -18.6 0.1 -18.1 -18.8 03/09/2005 10:40:00 9 1.3 12.6 6.5 8.8 1.3 12.6 6.5 0.4 0 0.4 0.4 23 7 32 305 21 0 20 0 -18.3 0.1 -17.9 -18.4 03/09/2005 10:50:00 8.9 1.4 11.8 5.7 8.8 1.3 11.8 5.7 0.4 0 0.4 0.4 19 6 17 305 21 0 21 0 -18 0.1 -17.7 -18.2 03/09/2005 11:00:00 10 1.3 13.3 7.2 9.9 1.3 13 6.8 0.4 0 0.4 0.4 16 5 12 305 22 0 22 0 -18 0 -17.5 -18.1 03/09/2005 11:10:00 9.6 1.2 13.3 7.2 9.5 1.2 12.6 7.2 0.4 0 0.4 0.4 19 5 25 305 23 0 23 0 -17.9 0.1 -17.5 -18.1 03/09/2005 11:20:00 10.5 1.1 13.3 7.2 10.4 1.1 13 7.6 0.4 0 0.4 0.4 20 6 20 305 24 0 24 0 -17.7 0 -17.5 -17.9 03/09/2005 11:30:00 11.1 1.1 13.3 8.4 10.9 1.1 13.7 8.4 0.4 0 0.4 0.4 22 6 23 305 25 0 24 0 -17.6 0 -17.3 -17.9 03/09/2005 11:40:00 11 1.2 14.1 8 10.8 1.3 14.1 8 0.4 0 0.4 0.4 18 6 14 305 25 0 26 0 -17.5 0 -17.1 -17.7 03/09/2005 11:50:00 12.1 1.2 15.6 8.8 12 1.3 16.1 8 0.4 0 0.4 0.4 23 5 24 305 27 0 27 0 -17.4 0.1 -16.9 -17.5 03/09/2005 12:00:00 12.1 1.7 16.1 8 11.8 1.8 15.6 7.2 0.4 0 0.4 0.4 26 6 19 305 27 0 27 0 -17.3 0.1 -16.9 -17.5 03/09/2005 12:10:00 13 1.3 16.1 9.5 12.7 1.5 15.6 8.4 0.4 0 0.4 0.4 24 6 27 305 28 0 28 0 -17.2 0 -16.9 -17.5 03/09/2005 12:20:00 13.2 1.1 15.6 10.3 12.9 1.2 15.6 9.5 0.4 0 0.4 0.4 27 5 25 305 28 0 28 0 -17.2 0 -16.9 -17.3 03/09/2005 12:30:00 12.2 1.4 14.9 8.4 12 1.4 14.9 8.4 0.4 0 0.4 0.4 24 5 26 305 28 0 28 0 -17.1 0 -16.9 -17.3 03/09/2005 12:40:00 11.6 1.1 13.7 8.8 11.4 1.1 14.1 8.4 0.4 0 0.4 0.4 23 6 19 305 29 0 28 0 -16.9 0 -16.6 -16.9 03/09/2005 12:50:00 13.3 1 15.6 10.3 13.1 1.2 16.1 9.5 0.4 0 0.4 0.4 22 6 21 305 29 0 29 0 -16.9 0 -16.6 -16.9 03/09/2005 13:00:00 10.7 1.2 14.5 8 10.5 1.2 13.7 7.6 0.4 0 0.4 0.4 23 7 21 305 30 0 29 0 -16.9 0 -16.4 -16.9 03/09/2005 13:10:00 13 1.8 16.1 8.8 12.6 1.7 16.4 8.4 0.4 0 0.4 0.4 19 7 18 305 30 0 30 0 -16.9 0 -16.6 -17.1 03/09/2005 13:20:00 13.1 1.5 16.4 9.5 12.8 1.5 16.4 8.4 0.4 0 0.4 0.4 23 6 19 305 31 0 31 0 -16.8 0.2 -16.4 -17.1 03/09/2005 13:30:00 13.1 1.4 16.4 9.5 13 1.4 16.1 9.5 0.4 0 0.4 0.4 20 5 13 305 31 0 31 0 -16.8 0.2 -16.4 -16.9 03/09/2005 13:40:00 13.5 1.3 16.4 10.3 13.4 1.3 16.4 10.3 0.4 0 0.4 0.4 22 6 13 305 31 0 31 0 -16.7 0.2 -16.2 -16.9 03/09/2005 13:50:00 13.1 1.5 16.4 9.5 13 1.5 16.8 9.1 0.4 0 0.4 0.4 20 5 27 305 31 0 31 0 -16.7 0.2 -16 -16.9 03/09/2005 14:00:00 12.2 1.5 16.1 8 12.2 1.5 16.1 8.4 0.4 0 0.4 0.4 19 6 22 305 31 0 31 0 -16.7 0.2 -16.2 -16.9 03/09/2005 14:10:00 11.1 1.2 13.7 8 10.9 1.3 14.1 7.6 0.4 0 0.4 0.4 22 6 18 305 32 0 32 0 -16.7 0.2 -16 -16.9 03/09/2005 14:20:00 12.8 1.8 16.8 7.6 12.4 1.8 16.4 7.2 0.4 0 0.4 0.4 26 6 23 305 32 0 32 0 -16.6 0.2 -16 -16.9 03/09/2005 14:30:00 12.5 1.8 16.1 8.4 12.2 1.8 16.1 8.4 0.4 0 0.4 0.4 28 6 30 305 32 0 32 0 -16.4 0.2 -15.8 -16.7 03/09/2005 14:40:00 12.6 1.3 15.3 8.8 12.4 1.3 15.6 8.8 0.4 0 0.4 0.4 26 6 31 305 33 0 33 0 -16.3 0.2 -16 -16.6 03/09/2005 14:50:00 12.2 1.3 14.9 8.8 11.9 1.3 15.3 8.4 0.4 0 0.4 0.4 22 5 22 305 33 0 33 0 -16.2 0.2 -15.8 -16.6 03/09/2005 15:00:00 13.9 1.3 17.2 9.9 13.5 1.4 17.6 9.1 0.4 0 0.4 0.4 22 5 18 305 34 0 34 0 -16.3 0.2 -15.8 -16.6 03/09/2005 15:10:00 12.3 1.6 16.1 8.4 12.1 1.6 16.1 7.6 0.4 0 0.4 0.4 24 5 18 305 34 0 34 0 -16.2 0.2 -15.6 -16.6 03/09/2005 15:20:00 14.4 1.3 17.6 11.5 14.2 1.3 17.6 10.7 0.4 0 0.4 0.4 23 5 25 305 34 0 34 0 -16.1 0.2 -15.6 -16.4 03/09/2005 15:30:00 13.7 1.2 17.2 10.7 13.4 1.3 17.2 9.9 0.4 0 0.4 0.4 25 6 23 305 34 0 34 0 -16.1 0.1 -15.6 -16.4 03/09/2005 15:40:00 13.3 1.2 16.8 9.9 13.1 1.3 16.8 9.1 0.4 0 0.4 0.4 20 6 18 305 34 0 34 0 -16.1 0 -15.8 -16.2 03/09/2005 15:50:00 13.1 1.5 16.4 8.8 12.9 1.7 16.4 8.4 0.4 0 0.4 0.4 21 5 21 305 34 0 34 0 -16 0 -15.6 -16.2 03/09/2005 16:00:00 13.6 1.3 17.9 10.7 13.2 1.4 17.2 9.5 0.4 0 0.4 0.4 22 6 21 305 35 0 35 0 -15.9 0 -15.4 -16 03/09/2005 16:10:00 13.9 1.5 17.2 10.3 13.6 1.6 16.8 10.3 0.4 0 0.4 0.4 23 5 14 305 35 0 35 0 -15.8 0 -15.2 -16 03/09/2005 16:20:00 13.4 1.5 17.6 10.3 13.2 1.4 16.1 9.9 0.4 0 0.4 0.4 22 6 27 305 35 0 35 0 -15.8 0 -15.4 -15.8 03/09/2005 16:30:00 13.7 1.7 17.6 9.9 13.5 1.7 17.6 9.5 0.4 0 0.4 0.4 21 6 15 305 35 0 35 0 -15.8 0 -15.4 -16 03/09/2005 16:40:00 13.3 1.5 16.8 9.1 13 1.5 16.8 9.9 0.4 0 0.4 0.4 19 5 23 305 35 0 36 0 -15.7 0.1 -15 -15.8 03/09/2005 16:50:00 14.1 1.3 16.8 10.7 13.9 1.4 16.8 10.7 0.4 0 0.4 0.4 19 5 15 305 36 0 35 0 -15.8 0 -15.4 -15.8 03/09/2005 17:00:00 13.3 1.3 16.1 9.9 13.1 1.3 16.1 9.9 0.4 0 0.4 0.4 20 6 23 305 36 0 36 0 -15.6 0.1 -15 -15.8 03/09/2005 17:10:00 13.8 1.3 16.4 10.3 13.6 1.3 17.2 10.3 0.4 0 0.4 0.4 21 6 26 305 36 0 35 0 -15.8 0 -15.4 -16 03/09/2005 17:20:00 14 1.5 17.6 9.9 13.8 1.3 17.9 10.3 0.4 0 0.4 0.4 20 5 19 305 35 0 35 0 -15.8 0 -15.4 -16 03/09/2005 17:30:00 13.7 1.3 17.2 10.3 13.5 1.3 16.8 9.1 0.4 0 0.4 0.4 20 6 10 305 34 0 35 0 -15.8 0 -15.6 -16 03/09/2005 17:40:00 14.8 1.5 19.1 10.7 14.7 1.5 19.1 10.7 0.4 0 0.4 0.4 19 5 16 305 34 0 34 0 -16.2 0.1 -15.8 -16.4 03/09/2005 17:50:00 14.5 1.7 18.3 11.1 14.2 1.7 17.9 10.7 0.4 0 0.4 0.4 19 5 25 305 33 0 32 0 -16.1 0.2 -15.6 -16.4 03/09/2005 18:00:00 14.2 1.6 17.6 10.7 14 1.7 17.9 10.7 0.4 0 0.4 0.4 20 5 19 305 32 0 32 0 -16.3 0.1 -15.8 -16.6 03/09/2005 18:10:00 14.6 1.7 19.1 10.3 14.3 1.8 18.7 9.5 0.4 0 0.4 0.4 15 5 21 305 31 0 31 0 -16.6 0.3 -15.8 -16.9 03/09/2005 18:20:00 14.8 1.7 19.1 11.1 14.6 1.7 18.7 11.1 0.4 0 0.4 0.4 20 5 22 305 31 0 31 0 -16.7 0.2 -16.4 -16.9 03/09/2005 18:30:00 15.3 1.2 18.3 11.8 15.1 1.3 18.3 11.8 0.4 0 0.4 0.4 20 5 24 305 30 0 29 0 -16.7 0.1 -16 -16.9 03/09/2005 18:40:00 15.4 1.4 19.1 11.5 15 1.5 19.5 11.1 0.4 0 0.4 0.4 20 5 15 305 29 0 29 0 -16.6 0.2 -16 -16.9 03/09/2005 18:50:00 15.7 1.3 19.1 12.6 15.6 1.3 19.1 11.8 0.4 0 0.4 0.4 19 5 14 305 29 0 29 0 -16.8 0.2 -16.4 -16.9 03/09/2005 19:00:00 14.6 1.6 17.9 10.7 14.5 1.6 17.9 11.1 0.4 0 0.4 0.4 20 6 25 305 29 0 29 0 -16.7 0.2 -16.2 -16.9 03/09/2005 19:10:00 14.8 1.3 18.3 11.1 14.6 1.5 17.6 11.1 0.4 0 0.4 0.4 19 5 17 305 28 0 28 0 -16.7 0.2 -16.4 -16.9 03/09/2005 19:20:00 14.5 1.5 18.7 11.1 14.4 1.5 18.7 11.1 0.4 0 0.4 0.4 22 5 22 305 28 0 28 0 -16.7 0.2 -16.2 -16.9 03/09/2005 19:30:00 15.7 1.7 19.1 11.1 15.5 1.8 19.1 10.7 0.4 0 0.4 0.4 22 5 24 305 28 0 28 0 -16.8 0.2 -16.4 -16.9 03/09/2005 19:40:00 16.3 1.6 19.9 11.5 16 1.6 19.5 11.8 0.4 0 0.4 0.4 23 5 23 305 28 0 28 0 -16.7 0.2 -16.4 -16.9 03/09/2005 19:50:00 14.6 1.4 17.9 9.5 14.4 1.5 17.9 8.8 0.4 0 0.4 0.4 24 5 31 305 28 0 28 0 -16.7 0.2 -16.2 -16.9 03/09/2005 20:00:00 14.6 1.3 18.7 10.7 14.3 1.4 18.3 10.7 0.4 0 0.4 0.4 26 5 26 305 28 0 28 0 -16.7 0.1 -16.2 -16.9 03/09/2005 20:10:00 15.8 1.3 18.7 11.8 15.4 1.3 17.9 11.5 0.4 0 0.4 0.4 24 5 30 305 28 0 28 0 -16.9 0 -16.4 -16.9 03/09/2005 20:20:00 14.5 1.4 18.3 11.1 14.2 1.5 18.3 11.1 0.4 0 0.4 0.4 24 6 16 305 28 0 28 0 -16.9 0 -16.4 -16.9 03/09/2005 20:30:00 15.3 1.5 18.7 11.8 15 1.5 18.7 12.2 0.4 0 0.4 0.4 26 5 29 305 27 0 27 0 -16.9 0 -16.6 -16.9 03/09/2005 20:40:00 15.1 1.7 18.3 11.5 14.9 1.7 17.9 10.7 0.4 0 0.4 0.4 28 5 30 305 27 0 27 0 -16.9 0 -16.4 -16.9 03/09/2005 20:50:00 16.1 1.5 19.5 11.8 15.8 1.5 19.5 11.5 0.4 0 0.4 0.4 26 5 23 305 27 0 27 0 -16.7 0.1 -16.2 -16.9 03/09/2005 21:00:00 16.8 1.5 19.5 12.6 16.4 1.4 19.5 11.8 0.4 0 0.4 0.4 27 4 31 305 27 0 27 0 -16.9 0 -16.4 -16.9 03/09/2005 21:10:00 15.6 1.6 19.5 11.5 15.2 1.5 18.7 11.8 0.4 0 0.4 0.4 28 5 24 305 27 0 27 0 -16.8 0 -16.6 -16.9 03/09/2005 21:20:00 15.3 1.3 18.3 11.5 15 1.3 17.9 11.5 0.4 0 0.4 0.4 29 5 31 305 27 0 27 0 -16.8 0 -16.4 -16.9 03/09/2005 21:30:00 15.1 1.2 18.3 12.2 14.6 1.2 18.3 11.5 0.4 0 0.4 0.4 28 4 30 305 27 0 27 0 -16.8 0 -16.6 -16.9 03/09/2005 21:40:00 15.8 1.3 19.5 12.6 15.4 1.4 19.1 11.8 0.4 0 0.4 0.4 27 4 29 305 27 0 27 0 -16.7 0.1 -16.6 -16.9 03/09/2005 21:50:00 15 1.3 18.7 11.5 14.6 1.3 17.9 11.5 0.4 0 0.4 0.4 28 5 30 305 27 0 27 0 -16.6 0 -16.4 -16.9 03/09/2005 22:00:00 15.6 1.3 18.7 12.6 15.2 1.3 18.3 12.2 0.4 0 0.4 0.4 27 5 29 305 27 0 27 0 -16.6 0 -16 -16.9 03/09/2005 22:10:00 15.4 1.4 18.3 11.8 15 1.3 17.9 11.5 0.4 0 0.4 0.4 29 5 29 305 28 0 27 0 -16.6 0.1 -16.4 -16.9 03/09/2005 22:20:00 15.9 1.3 19.1 12.2 15.6 1.4 18.7 11.1 0.4 0 0.4 0.4 28 5 30 305 28 0 28 0 -16.6 0.2 -16 -16.9 03/09/2005 22:30:00 15.7 1.4 19.5 12.6 15.2 1.4 18.7 11.8 0.4 0 0.4 0.4 29 5 27 305 28 0 28 0 -16.6 0.2 -16.2 -16.9 03/09/2005 22:40:00 15 1.4 18.3 11.5 14.8 1.4 17.9 11.1 0.4 0 0.4 0.4 29 5 27 305 28 0 28 0 -16.6 0.2 -16 -16.9 03/09/2005 22:50:00 15.3 1.4 18.3 11.1 15 1.3 17.9 11.1 0.4 0 0.4 0.4 27 5 29 305 28 0 28 0 -16.6 0.1 -16 -16.9 03/09/2005 23:00:00 15.9 1.5 19.1 11.8 15.5 1.5 18.7 12.6 0.4 0 0.4 0.4 28 5 29 305 28 0 27 0 -16.6 0.2 -16.2 -16.9 03/09/2005 23:10:00 15.4 1.3 18.7 12.2 15.1 1.3 18.7 12.2 0.4 0 0.4 0.4 27 5 23 305 28 0 27 0 -16.7 0.2 -16.4 -16.9 03/09/2005 23:20:00 15.3 1.4 19.1 11.8 14.9 1.5 17.9 11.5 0.4 0 0.4 0.4 25 5 19 305 27 0 27 0 -16.7 0.2 -16.2 -16.9 03/09/2005 23:30:00 15.7 1.3 18.7 11.5 15.2 1.5 18.7 10.7 0.4 0 0.4 0.4 24 5 23 305 27 0 27 0 -16.8 0.2 -16.4 -16.9 03/09/2005 23:40:00 16 1.3 19.1 11.5 15.6 1.3 19.5 12.2 0.4 0 0.4 0.4 25 5 21 305 27 0 27 0 -16.7 0.2 -16.4 -16.9 03/09/2005 23:50:00 15.1 1.2 18.7 12.2 14.8 1.2 17.6 11.8 0.4 0 0.4 0.4 27 5 22 305 27 0 27 0 -16.6 0.2 -16 -16.9 03/10/2005 00:00:00 14.5 1.3 17.6 11.8 14.3 1.3 17.9 11.1 0.4 0 0.4 0.4 25 4 20 305 27 0 27 0 -16.5 0.1 -16 -16.9 03/10/2005 00:10:00 15.8 1.2 18.3 12.6 15.4 1.3 17.9 11.8 0.4 0 0.4 0.4 27 5 33 305 27 0 28 0 -16.6 0 -16 -16.7 03/10/2005 00:20:00 15 1.3 17.9 11.5 14.5 1.3 17.6 10.3 0.4 0 0.4 0.4 28 5 19 305 28 0 27 0 -16.4 0 -15.8 -16.6 03/10/2005 00:30:00 14.6 1.3 17.9 11.5 14.3 1.2 17.2 11.1 0.4 0 0.4 0.4 29 5 31 305 28 0 28 0 -16.3 0.1 -15.8 -16.4 03/10/2005 00:40:00 14.8 1.2 17.6 11.8 14.5 1.2 17.6 11.1 0.4 0 0.4 0.4 26 5 30 305 28 0 28 0 -16.3 0.1 -15.8 -16.6 03/10/2005 00:50:00 14.7 1.2 19.1 12.2 14.3 1.2 18.7 11.5 0.4 0 0.4 0.4 28 5 32 305 28 0 28 0 -16.2 0.1 -15.8 -16.4 03/10/2005 01:00:00 15.5 1.7 19.9 11.1 15.1 1.8 19.5 11.5 0.4 0 0.4 0.4 33 6 36 305 29 0 28 0 -15.8 0.1 -15.2 -16 03/10/2005 01:10:00 15.6 2 19.9 10.7 15.2 1.9 19.1 9.9 0.4 0 0.4 0.4 32 6 44 305 29 0 29 0 -15.6 0.1 -15 -15.8 03/10/2005 01:20:00 16.9 1.7 21.8 12.6 16.6 1.8 21.4 12.2 0.4 0 0.4 0.4 35 5 39 305 30 0 30 0 -15.6 0.1 -15 -15.8 03/10/2005 01:30:00 13.8 1.2 17.6 11.1 13.4 1.2 16.4 10.7 0.4 0 0.4 0.4 27 5 21 305 30 0 30 0 -15.7 0.1 -15 -15.8 03/10/2005 01:40:00 14.2 1.4 17.2 11.1 13.9 1.3 16.8 11.1 0.4 0 0.4 0.4 25 5 29 305 30 0 30 0 -15.8 0 -15.2 -16 03/10/2005 01:50:00 14.3 1.2 17.9 11.1 13.9 1.2 17.6 11.1 0.4 0 0.4 0.4 26 5 29 305 30 0 30 0 -15.8 0 -15.4 -16 03/10/2005 02:00:00 14.3 1.2 17.2 10.7 14.1 1.3 17.6 11.1 0.4 0 0.4 0.4 24 5 13 305 30 0 30 0 -15.8 0 -15.4 -16 03/10/2005 02:10:00 15 1.2 18.7 12.2 14.7 1.2 17.6 11.8 0.4 0 0.4 0.4 29 5 28 305 30 0 30 0 -15.8 0 -15.2 -16 03/10/2005 02:20:00 14.5 1.3 17.2 11.5 14.2 1.2 17.2 11.1 0.4 0 0.4 0.4 29 5 32 305 30 0 30 0 -15.6 0.1 -15 -15.8 03/10/2005 02:30:00 16.5 1.7 20.6 12.2 16.1 1.7 19.9 12.2 0.4 0 0.4 0.4 31 5 29 305 30 0 31 0 -15.5 0.1 -14.8 -15.8 03/10/2005 02:40:00 17.9 1.6 22.1 13.7 17.5 1.6 22.6 13.7 0.4 0 0.4 0.4 35 5 35 305 31 0 31 0 -15.3 0.1 -14.8 -15.6 03/10/2005 02:50:00 17.3 1.4 21.4 14.5 16.9 1.4 21.8 13.3 0.4 0 0.4 0.4 34 5 36 305 31 0 31 0 -15.3 0 -14.6 -15.6 03/10/2005 03:00:00 17.9 1.5 22.1 13.7 17.5 1.5 21.4 13.3 0.4 0 0.4 0.4 35 5 37 305 32 0 32 0 -15.2 0.2 -14.6 -15.4 03/10/2005 03:10:00 17.5 1.6 21.4 13.7 17.2 1.7 20.6 13 0.4 0 0.4 0.4 36 5 31 305 32 0 32 0 -15.1 0.2 -14.6 -15.4 03/10/2005 03:20:00 17 1.3 19.9 13.7 16.8 1.3 19.9 13.3 0.4 0 0.4 0.4 36 5 39 305 32 0 32 0 -15.1 0.2 -14.6 -15.2 03/10/2005 03:30:00 17.9 1.7 21.4 13.3 17.6 1.7 21.4 12.6 0.4 0 0.4 0.4 33 5 39 305 32 0 32 0 -15.1 0.1 -14.6 -15.2 03/10/2005 03:40:00 17.2 1.9 21 13.3 16.7 1.9 21.8 12.2 0.4 0 0.4 0.4 32 6 38 305 33 0 33 0 -15 0.2 -14.6 -15.2 03/10/2005 03:50:00 16.7 1.6 20.6 12.6 16.1 1.7 20.2 11.8 0.4 0 0.4 0.4 33 6 23 305 33 0 33 0 -14.9 0.1 -14.4 -15 03/10/2005 04:00:00 17 1.8 21 11.5 16.5 1.7 20.2 11.8 0.4 0 0.4 0.4 33 5 35 305 33 0 33 0 -14.9 0.1 -14.4 -15 03/10/2005 04:10:00 16.4 1.6 19.9 12.2 16 1.6 20.2 11.8 0.4 0 0.4 0.4 36 6 40 305 33 0 33 0 -15 0.1 -14.4 -15.2 03/10/2005 04:20:00 17.2 1.6 21.8 13.3 16.8 1.6 21.4 13 0.4 0 0.4 0.4 34 6 30 305 33 0 33 0 -15.1 0.1 -14.6 -15.2 03/10/2005 04:30:00 16.5 1.7 21 12.6 16.2 1.7 20.6 12.2 0.4 0 0.4 0.4 34 6 33 305 33 0 33 0 -15.2 0.1 -14.6 -15.4 03/10/2005 04:40:00 16.8 1.7 22.1 13.3 16.4 1.8 21.8 12.6 0.4 0 0.4 0.4 37 6 30 305 33 0 33 0 -15.3 0 -14.6 -15.6 03/10/2005 04:50:00 18.9 1.7 22.9 13 18.6 1.8 22.6 13.3 0.4 0 0.4 0.4 36 5 36 305 33 0 33 0 -15.4 0.1 -14.8 -15.6 03/10/2005 05:00:00 18.3 1.6 21.8 14.1 17.8 1.5 21.4 13.3 0.4 0 0.4 0.4 34 5 28 305 32 0 32 0 -15.5 0.1 -15 -15.6 03/10/2005 05:10:00 18.3 1.7 22.6 14.1 17.8 1.7 22.1 13.7 0.4 0 0.4 0.4 34 6 37 305 32 0 32 0 -15.5 0.1 -15 -15.6 03/10/2005 05:20:00 17.7 1.6 21.4 13.7 17.3 1.6 21.4 13 0.4 0 0.4 0.4 34 5 31 305 32 0 32 0 -15.5 0.1 -15 -15.6 03/10/2005 05:30:00 18.8 1.5 22.6 14.9 18.3 1.4 22.1 14.5 0.4 0 0.4 0.4 34 5 35 305 32 0 32 0 -15.6 0.1 -15 -15.8 03/10/2005 05:40:00 18 1.7 22.1 13.7 17.5 1.7 21.4 13.3 0.4 0 0.4 0.4 32 5 26 305 32 0 32 0 -15.7 0.1 -15 -15.8 03/10/2005 05:50:00 17.2 1.7 20.6 13.3 16.9 1.7 20.2 13 0.4 0 0.4 0.4 34 4 30 305 31 0 32 0 -15.6 0.1 -15 -15.8 03/10/2005 06:00:00 17.3 1.2 20.2 13.7 16.9 1.3 20.2 13 0.4 0 0.4 0.4 34 5 29 305 31 0 31 0 -15.7 0.1 -15.2 -16 03/10/2005 06:10:00 17.5 1.4 20.6 14.1 17.1 1.4 20.2 13.3 0.4 0 0.4 0.4 34 4 32 305 31 0 31 0 -15.8 0.1 -15.2 -16 03/10/2005 06:20:00 16.8 1.4 20.6 13.7 16.3 1.4 21 13 0.4 0 0.4 0.4 34 5 29 305 31 0 31 0 -15.8 0.1 -15.2 -16 03/10/2005 06:30:00 16.5 1.5 19.9 13.3 16.4 1.5 20.2 13 0.4 0 0.4 0.4 40 5 42 305 31 0 31 0 -15.7 0.1 -15 -15.8 03/10/2005 06:40:00 15 1.2 17.9 11.8 14.7 1.2 17.6 12.2 0.4 0 0.4 0.4 37 5 27 305 31 0 31 0 -15.8 0.1 -15.2 -15.8 03/10/2005 06:50:00 15 1.1 17.6 12.2 14.7 1 17.2 12.2 0.4 0 0.4 0.4 37 6 48 305 31 0 31 0 -15.8 0.1 -15.2 -15.8 03/10/2005 07:00:00 17.1 1.7 20.6 13 16.7 1.8 20.6 11.5 0.4 0 0.4 0.4 35 4 36 305 31 0 31 0 -15.8 0.1 -15.2 -16 03/10/2005 07:10:00 18.4 1.7 21.8 13 18 1.6 22.1 13.7 0.4 0 0.4 0.4 38 6 35 305 31 0 31 0 -15.8 0.1 -15.2 -16 03/10/2005 07:20:00 16 1.3 19.5 13.3 15.7 1.3 20.2 13 0.4 0 0.4 0.4 35 6 32 305 31 0 31 0 -15.8 0.1 -15.2 -16 03/10/2005 07:30:00 16.4 1.8 20.2 12.2 16 1.7 19.9 12.2 0.4 0 0.4 0.4 34 6 34 305 31 0 31 0 -15.8 0.1 -15.2 -16 03/10/2005 07:40:00 16.9 1.3 19.9 13.7 16.6 1.4 19.9 13 0.4 0 0.4 0.4 34 4 35 305 31 0 31 0 -15.7 0.2 -15.2 -16 03/10/2005 07:50:00 17.8 1.5 22.1 14.5 17.5 1.5 21.8 14.5 0.4 0 0.4 0.4 38 6 27 305 31 0 31 0 -15.8 0.1 -15.2 -16 03/10/2005 08:00:00 15.5 1.2 18.3 12.6 15.2 1.3 17.9 11.5 0.4 0 0.4 0.4 32 5 26 305 30 0 31 0 -15.8 0.1 -15.2 -16 03/10/2005 08:10:00 16.9 1.7 21.4 13 16.5 1.7 21.4 12.2 0.4 0 0.4 0.4 33 5 29 305 30 0 31 0 -15.8 0 -15.4 -16 03/10/2005 08:20:00 16.5 1.6 20.2 13 16.2 1.6 19.9 12.2 0.4 0 0.4 0.4 36 5 36 305 30 0 31 0 -15.8 0.1 -15.2 -15.8 03/10/2005 08:30:00 15.7 1.5 19.9 12.6 15.4 1.6 19.1 11.8 0.4 0 0.4 0.4 35 5 27 305 30 0 31 0 -15.8 0 -15.2 -16 03/10/2005 08:40:00 16.8 1.7 21.8 13.3 16.5 1.7 21.4 13 0.4 0 0.4 0.4 37 5 33 305 31 0 31 0 -15.8 0.1 -15.2 -15.8 03/10/2005 08:50:00 16.5 1.7 20.6 12.2 16.3 1.7 21 11.8 0.4 0 0.4 0.4 37 5 41 305 31 0 31 0 -15.8 0.1 -15.2 -15.8 03/10/2005 09:00:00 16.4 1.1 19.5 12.2 15.9 1.2 19.1 12.6 0.4 0 0.4 0.4 34 4 34 305 31 0 31 0 -15.8 0.1 -15.2 -16 03/10/2005 09:10:00 16.5 1.2 19.5 13.7 16.1 1.3 19.5 13 0.4 0 0.4 0.4 33 4 38 305 31 0 31 0 -15.8 0.1 -15.2 -16 03/10/2005 09:20:00 16.9 1.2 19.5 13.7 16.6 1.2 19.5 13.7 0.4 0 0.4 0.4 33 4 28 305 30 0 31 0 -15.7 0.2 -15.2 -16 03/10/2005 09:30:00 16.6 1.3 19.5 13 16.4 1.4 19.9 12.6 0.4 0 0.4 0.4 34 4 34 305 31 0 31 0 -15.8 0.1 -15.2 -16 03/10/2005 09:40:00 16.9 1.2 19.9 14.1 16.7 1.1 19.1 12.6 0.4 0 0.4 0.4 36 5 32 305 31 0 31 0 -15.7 0.2 -15 -15.8 03/10/2005 09:50:00 16.2 1.4 21 12.2 16 1.4 20.6 12.6 0.4 0 0.4 0.4 39 5 48 305 31 0 31 0 -15.7 0.1 -15.2 -15.8 03/10/2005 10:00:00 17.2 1.4 20.2 13.7 16.9 1.4 20.2 13.3 0.4 0 0.4 0.4 40 5 39 305 31 0 31 0 -15.6 0.1 -15 -15.8 03/10/2005 10:10:00 17.7 1.4 21.4 14.1 17.3 1.4 21.4 14.1 0.4 0 0.4 0.4 39 5 42 305 31 0 31 0 -15.6 0.1 -15 -15.8 03/10/2005 10:20:00 17.4 1.3 20.6 13.7 17.2 1.5 21 13.3 0.4 0 0.4 0.4 42 5 39 305 31 0 31 0 -15.6 0.1 -15 -15.8 03/10/2005 10:30:00 18.1 1.5 21.8 14.1 17.9 1.5 21.4 14.1 0.4 0 0.4 0.4 41 5 40 305 32 0 32 0 -15.6 0.1 -15 -15.8 03/10/2005 10:40:00 18.1 1.6 23.7 14.5 17.8 1.6 23.3 14.1 0.4 0 0.4 0.4 40 6 41 305 32 0 32 0 -15.5 0.1 -15 -15.6 03/10/2005 10:50:00 17.6 1.7 21.8 14.5 17.3 1.6 21.4 14.1 0.4 0 0.4 0.4 40 5 39 305 32 0 32 0 -15.5 0 -15 -15.6 03/10/2005 11:00:00 17.7 1.5 22.6 14.1 17.4 1.5 22.9 14.1 0.4 0 0.4 0.4 41 5 40 305 32 0 32 0 -15.4 0.1 -14.8 -15.6 03/10/2005 11:10:00 17.4 1.2 20.2 14.5 17 1.2 19.9 13.7 0.4 0 0.4 0.4 40 4 40 305 33 0 32 0 -15.3 0.1 -14.6 -15.6 03/10/2005 11:20:00 16.2 1.5 19.5 13 15.9 1.5 19.5 12.2 0.4 0 0.4 0.4 38 5 37 305 33 0 33 0 -15.2 0.1 -14.6 -15.4 03/10/2005 11:30:00 15.4 1.1 18.3 12.6 15.2 1.1 17.9 12.2 0.4 0 0.4 0.4 38 5 38 305 34 0 33 0 -15.2 0.1 -14.6 -15.4 03/10/2005 11:40:00 15.1 1.1 17.6 11.5 14.9 1.2 17.6 10.7 0.4 0 0.4 0.4 39 5 38 305 34 0 34 0 -15.1 0.1 -14.6 -15.2 03/10/2005 11:50:00 16.9 1.6 21.4 13.3 16.7 1.7 21.8 13 0.4 0 0.4 0.4 38 5 39 305 35 0 35 0 -15 0.1 -14.4 -15 03/10/2005 12:00:00 16.8 1.6 20.6 13.7 16.6 1.6 20.2 13.3 0.4 0 0.4 0.4 40 6 32 305 36 0 36 0 -14.8 0.2 -14.3 -15 03/10/2005 12:10:00 16.9 1.5 21.4 12.6 16.7 1.6 21 13 0.4 0 0.4 0.4 44 5 30 305 39 1 38 0 -14.7 0.1 -14.3 -15 03/10/2005 12:20:00 17.3 1.3 20.6 14.1 17.1 1.3 20.6 13.7 0.4 0 0.4 0.4 42 5 56 305 42 1 42 0 -14.6 0.2 -14.3 -14.6 03/10/2005 12:30:00 17.1 1.7 21.4 13.3 16.8 1.7 21 13.3 0.4 0 0.4 0.4 45 5 37 305 44 1 45 0 -14.5 0.2 -14.1 -14.6 03/10/2005 12:40:00 17.6 1.6 21.4 13.3 17.3 1.6 21.4 13 0.4 0 0.4 0.4 46 6 40 305 45 0 45 0 -14.6 0.2 -14.3 -14.8 03/10/2005 12:50:00 15.3 1.3 19.1 13 15 1.3 18.7 11.8 0.4 0 0.4 0.4 47 5 47 305 44 0 45 0 -14.6 0.1 -14.3 -14.8 03/10/2005 13:00:00 16 1.4 21.4 13.3 15.7 1.5 20.2 12.6 0.4 0 0.4 0.4 48 4 46 305 44 0 43 0 -14.6 0.2 -14.3 -14.8 03/10/2005 13:10:00 17.8 1.5 21.4 14.1 17.5 1.6 21.8 13.3 0.4 0 0.4 0.4 46 5 45 305 43 0 42 0 -14.6 0.2 -14.3 -14.8 03/10/2005 13:20:00 17.3 1.6 22.6 13.7 17 1.7 21.4 13.7 0.4 0 0.4 0.4 48 4 46 305 42 0 42 0 -14.6 0.2 -14.3 -14.8 03/10/2005 13:30:00 16.4 1.2 19.9 13.3 16.2 1.3 19.5 13.3 0.4 0 0.4 0.4 49 5 40 305 41 0 41 0 -14.6 0.1 -14.3 -14.6 03/10/2005 13:40:00 16.9 1.2 20.2 13.3 16.6 1.3 19.9 12.6 0.4 0 0.4 0.4 48 5 48 305 41 0 41 0 -14.5 0.2 -13.9 -14.6 03/10/2005 13:50:00 17 1.1 19.9 14.1 16.7 1.2 19.5 13.3 0.4 0 0.4 0.4 49 5 50 305 42 0 42 0 -14.5 0.2 -14.1 -14.6 03/10/2005 14:00:00 17.9 1.5 21.4 14.9 17.6 1.5 21.4 14.5 0.4 0 0.4 0.4 49 5 43 305 42 0 42 0 -14.4 0.2 -13.9 -14.6 03/10/2005 14:10:00 17.3 1.3 21 13.7 16.9 1.4 21.4 13.3 0.4 0 0.4 0.4 49 4 50 305 42 0 42 0 -14.4 0.2 -13.9 -14.6 03/10/2005 14:20:00 16.6 1.7 20.6 13.3 16.2 1.7 20.6 13 0.4 0 0.4 0.4 50 5 48 305 41 0 41 0 -14.4 0.1 -13.7 -14.6 03/10/2005 14:30:00 12.8 1 16.4 10.7 12.5 1 16.1 10.3 0.4 0 0.4 0.4 34 5 42 305 42 0 41 0 -14.8 0.2 -13.9 -15 03/10/2005 14:40:00 12.5 0.9 14.5 9.9 12.2 1 14.1 9.5 0.4 0 0.4 0.4 31 5 27 305 42 0 42 0 -15.3 0.2 -14.6 -15.6 03/10/2005 14:50:00 12.6 0.9 14.5 9.5 12.5 0.9 14.5 9.5 0.4 0 0.4 0.4 29 4 33 305 42 0 42 0 -15.5 0.1 -15 -15.6 03/10/2005 15:00:00 12.5 1 14.5 9.9 12.3 1 14.5 9.9 0.4 0 0.4 0.4 31 4 32 305 42 0 42 0 -15.5 0.1 -14.8 -15.6 03/10/2005 15:10:00 13.1 0.8 14.5 10.3 12.9 0.9 15.3 10.3 0.4 0 0.4 0.4 26 3 24 305 43 0 42 0 -15.4 0.1 -14.6 -15.6 03/10/2005 15:20:00 12.9 1.2 16.1 9.5 12.7 1.2 16.1 9.9 0.4 0 0.4 0.4 28 4 26 305 43 0 43 0 -15.4 0.1 -14.8 -15.6 03/10/2005 15:30:00 13.5 0.9 15.3 10.7 13.4 0.9 15.6 10.7 0.4 0 0.4 0.4 28 5 35 305 43 0 43 0 -15.3 0.1 -14.8 -15.6 03/10/2005 15:40:00 14.6 1.4 17.2 11.1 14.4 1.3 17.2 11.1 0.4 0 0.4 0.4 25 4 30 305 42 0 42 0 -15.6 0.1 -15 -15.8 03/10/2005 15:50:00 14.6 1.3 17.2 10.3 14.3 1.3 16.8 10.7 0.4 0 0.4 0.4 26 4 26 305 42 0 42 0 -15.6 0.1 -15 -15.8 03/10/2005 16:00:00 14.4 1.2 16.8 11.1 14.1 1.3 17.2 9.9 0.4 0 0.4 0.4 25 4 22 305 41 0 41 0 -15.5 0.1 -14.8 -15.6 03/10/2005 16:10:00 14.4 1.2 16.8 11.5 14.2 1.3 17.2 11.5 0.4 0 0.4 0.4 24 5 20 305 40 0 40 0 -15.5 0.1 -15 -15.8 03/10/2005 16:20:00 14.1 1.1 16.4 10.3 13.9 1.2 16.4 10.3 0.4 0 0.4 0.4 27 5 27 305 40 0 40 0 -15.5 0.1 -15 -15.6 03/10/2005 16:30:00 14.5 1.3 17.2 11.1 14.2 1.3 17.6 11.1 0.4 0 0.4 0.4 26 5 26 305 41 0 41 0 -15.5 0.1 -15 -15.8 03/10/2005 16:40:00 13.6 1.2 16.4 10.3 13.4 1.2 16.4 10.3 0.4 0 0.4 0.4 26 5 24 305 41 0 41 0 -15.3 0.2 -14.8 -15.6 03/10/2005 16:50:00 13.6 1.2 16.4 10.3 13.5 1.1 16.4 10.7 0.4 0 0.4 0.4 22 5 24 305 41 0 41 0 -15.5 0.2 -14.8 -15.6 03/10/2005 17:00:00 14.8 1.1 17.9 11.1 14.5 1.3 17.9 11.1 0.4 0 0.4 0.4 25 5 25 305 40 0 40 0 -15.5 0.1 -15 -15.8 03/10/2005 17:10:00 14.6 1.2 17.6 11.5 14.3 1.1 17.2 11.8 0.4 0 0.4 0.4 30 5 36 305 39 0 39 0 -15.3 0.1 -14.8 -15.6 03/10/2005 17:20:00 12.9 1.5 15.6 9.5 12.7 1.5 16.1 9.1 0.4 0 0.4 0.4 29 5 27 305 39 0 39 0 -15.1 0.2 -14.6 -15.4 03/10/2005 17:30:00 12.6 1.3 15.6 8.8 12.3 1.5 14.9 8.4 0.4 0 0.4 0.4 26 6 28 305 39 0 39 0 -15.1 0.1 -14.6 -15.2 03/10/2005 17:40:00 13 1.4 17.2 9.5 12.7 1.4 16.8 9.1 0.4 0 0.4 0.4 24 5 25 305 40 0 40 0 -15.3 0.1 -14.6 -15.6 03/10/2005 17:50:00 12.4 1.4 16.8 9.5 12.2 1.5 16.1 9.1 0.4 0 0.4 0.4 29 6 25 305 40 0 40 0 -15.1 0.1 -14.6 -15.4 03/10/2005 18:00:00 12.9 1.2 16.4 9.9 12.7 1.2 16.8 9.9 0.4 0 0.4 0.4 30 5 29 305 40 0 40 0 -15.1 0.1 -14.4 -15.2 03/10/2005 18:10:00 14.3 1.3 17.2 11.1 14 1.3 17.6 10.3 0.4 0 0.4 0.4 27 6 24 305 39 0 39 0 -15.1 0.2 -14.6 -15.2 03/10/2005 18:20:00 13.5 1.7 17.2 9.9 13.2 1.7 16.8 9.9 0.4 0 0.4 0.4 29 5 22 305 38 0 38 0 -15.2 0.2 -14.6 -15.6 03/10/2005 18:30:00 12.9 1.2 16.1 9.9 12.7 1.2 15.6 9.9 0.4 0 0.4 0.4 29 5 38 305 37 0 38 0 -15.3 0.1 -14.8 -15.6 03/10/2005 18:40:00 13 1.1 15.3 9.1 12.7 1.2 15.6 9.1 0.4 0 0.4 0.4 27 6 21 305 36 0 37 0 -15.2 0.1 -14.6 -15.4 03/10/2005 18:50:00 13.1 1.5 17.2 9.9 12.9 1.5 16.1 9.9 0.4 0 0.4 0.4 31 5 29 305 36 0 36 0 -15.1 0.1 -14.6 -15.2 03/10/2005 19:00:00 13.8 1.3 16.4 9.9 13.6 1.5 16.8 9.9 0.4 0 0.4 0.4 30 5 35 305 36 0 35 0 -15.1 0.1 -14.4 -15.4 03/10/2005 19:10:00 13.1 1.2 16.8 9.5 12.8 1.3 17.6 9.5 0.4 0 0.4 0.4 26 6 29 305 35 0 35 0 -15.2 0.1 -14.6 -15.4 03/10/2005 19:20:00 12.6 1.3 15.6 9.1 12.4 1.3 15.6 9.1 0.4 0 0.4 0.4 29 6 29 305 35 0 35 0 -15 0.1 -14.6 -15.2 03/10/2005 19:30:00 12.6 1.6 17.6 9.1 12.3 1.6 16.4 9.1 0.4 0 0.4 0.4 26 7 22 305 35 0 35 0 -15.2 0.1 -14.6 -15.6 03/10/2005 19:40:00 13.7 1.4 16.4 10.3 13.4 1.5 16.8 9.9 0.4 0 0.4 0.4 27 5 23 305 35 0 35 0 -15.3 0 -14.8 -15.6 03/10/2005 19:50:00 13.5 1.6 16.8 9.5 13.2 1.5 16.8 9.5 0.4 0 0.4 0.4 27 5 19 305 34 0 34 0 -15.4 0 -15 -15.6 03/10/2005 20:00:00 11.8 1 14.9 9.1 11.6 1 14.5 9.1 0.4 0 0.4 0.4 27 5 33 305 34 0 34 0 -15.4 0.1 -15 -15.6 03/10/2005 20:10:00 12.4 1.2 14.9 9.5 12.2 1.2 14.5 9.1 0.4 0 0.4 0.4 26 5 25 305 33 0 34 0 -15.6 0.1 -15 -15.8 03/10/2005 20:20:00 13.3 2 17.9 8.8 13.1 2.1 17.9 8.8 0.4 0 0.4 0.4 28 6 22 305 33 0 32 0 -15.7 0.1 -15 -15.8 03/10/2005 20:30:00 13.2 1.7 17.6 9.5 13 1.7 17.2 9.5 0.4 0 0.4 0.4 27 5 20 305 32 0 32 0 -15.8 0 -15.2 -16 03/10/2005 20:40:00 13 1.1 17.6 10.3 12.8 1.2 16.4 9.9 0.4 0 0.4 0.4 24 5 23 305 32 0 32 0 -16 0.1 -15.6 -16.2 03/10/2005 20:50:00 11.4 1.1 14.1 8 11.2 1.1 14.1 8.4 0.4 0 0.4 0.4 25 6 25 305 31 0 31 0 -16.1 0 -15.8 -16.4 03/10/2005 21:00:00 10.6 1.1 14.1 8 10.5 1.1 13.3 8 0.4 0 0.4 0.4 24 6 12 305 30 0 30 0 -16.1 0.1 -15.8 -16.4 03/10/2005 21:10:00 11.4 1.5 14.5 8.4 11.2 1.4 14.9 7.2 0.4 0 0.4 0.4 26 5 30 305 30 0 30 0 -16.2 0.1 -15.8 -16.4 03/10/2005 21:20:00 11.9 1.1 14.5 9.1 11.8 1.2 14.5 8.4 0.4 0 0.4 0.4 26 6 22 305 29 0 29 0 -16.3 0.1 -15.8 -16.4 03/10/2005 21:30:00 10.9 1.3 14.9 8.4 10.8 1.4 14.9 8 0.4 0 0.4 0.4 27 6 31 305 29 0 29 0 -16.3 0.1 -16 -16.6 03/10/2005 21:40:00 9.8 1.1 13 6.5 9.6 1.2 13 6.5 0.4 0 0.4 0.4 26 6 30 305 29 0 28 0 -16.2 0.1 -15.8 -16.6 03/10/2005 21:50:00 11 1.2 14.5 8.4 10.8 1.2 14.5 8.4 0.4 0 0.4 0.4 27 6 24 305 28 0 28 0 -16.2 0.1 -15.8 -16.4 03/10/2005 22:00:00 12 1.3 16.8 8.8 11.7 1.3 16.8 8.4 0.4 0 0.4 0.4 29 6 18 305 28 0 28 0 -16.2 0.1 -15.8 -16.4 03/10/2005 22:10:00 12.5 1.2 16.1 8.8 12.3 1.3 16.4 8.8 0.4 0 0.4 0.4 27 6 17 305 28 0 28 0 -16.2 0.1 -15.8 -16.6 03/10/2005 22:20:00 10.9 1.2 15.3 8 10.6 1.2 14.5 8 0.4 0 0.4 0.4 27 5 39 305 28 0 28 0 -16.2 0.2 -15.8 -16.4 03/10/2005 22:30:00 12.2 1.4 16.8 9.1 12 1.4 16.8 8.8 0.4 0 0.4 0.4 25 6 22 305 28 0 28 0 -16 0.1 -15.6 -16.2 03/10/2005 22:40:00 12.5 1.4 17.2 9.5 12.4 1.5 17.2 9.5 0.4 0 0.4 0.4 24 5 18 305 28 0 28 0 -15.8 0.1 -15.4 -16 03/10/2005 22:50:00 12.3 1.6 16.8 8.4 12.2 1.6 17.6 8.4 0.4 0 0.4 0.4 23 6 14 305 28 0 28 0 -15.8 0.1 -15.2 -16 03/10/2005 23:00:00 12.2 1.2 14.9 8.8 12.1 1.1 14.9 9.5 0.4 0 0.4 0.4 25 6 30 305 29 0 29 0 -15.7 0.2 -15.2 -15.8 03/10/2005 23:10:00 13.4 1.5 16.4 9.5 13.3 1.5 16.4 9.5 0.4 0 0.4 0.4 26 5 38 305 29 0 29 0 -15.7 0.1 -15.2 -16 03/10/2005 23:20:00 12.4 1 15.3 9.5 12.2 1 14.9 9.5 0.4 0 0.4 0.4 27 6 32 305 29 0 29 0 -15.8 0.1 -15.2 -16 03/10/2005 23:30:00 12.2 1.2 14.5 9.1 12.1 1.2 15.3 8.8 0.4 0 0.4 0.4 28 5 31 305 30 0 30 0 -15.8 0 -15.4 -16 03/10/2005 23:40:00 11.6 1.1 14.5 8.8 11.4 1.2 14.1 8.4 0.4 0 0.4 0.4 27 5 29 305 30 0 30 0 -15.8 0.1 -15.2 -16 03/10/2005 23:50:00 11.5 1.2 14.5 8.8 11.3 1.1 14.5 8 0.4 0 0.4 0.4 28 6 27 305 30 0 30 0 -15.8 0.1 -15.2 -16 03/11/2005 00:00:00 12.8 1.4 17.6 9.5 12.6 1.4 16.8 9.5 0.4 0 0.4 0.4 30 5 24 305 30 0 30 0 -15.9 0 -15.2 -16.2 03/11/2005 00:10:00 12.7 1.4 16.8 8.4 12.6 1.4 15.6 8.4 0.4 0 0.4 0.4 29 6 33 305 30 0 30 0 -16 0 -15.8 -16.2 03/11/2005 00:20:00 13.9 1.1 16.4 10.7 13.6 1.1 16.4 10.7 0.4 0 0.4 0.4 26 5 31 305 30 0 29 0 -16 0 -15.6 -16.2 03/11/2005 00:30:00 13.5 1.2 16.8 10.3 13.3 1.3 16.4 10.3 0.4 0 0.4 0.4 25 5 27 305 29 0 29 0 -16.1 0.1 -15.6 -16.4 03/11/2005 00:40:00 13.2 1.4 16.4 9.9 13 1.5 16.4 9.5 0.4 0 0.4 0.4 25 5 19 305 29 0 29 0 -16.3 0 -16 -16.4 03/11/2005 00:50:00 13.7 1.2 16.1 9.9 13.5 1.2 16.4 9.9 0.4 0 0.4 0.4 25 5 23 305 29 0 29 0 -16.4 0 -16 -16.6 03/11/2005 01:00:00 13 1.4 16.8 9.5 12.8 1.4 16.8 9.5 0.4 0 0.4 0.4 24 5 19 305 29 0 29 0 -16.4 0 -15.8 -16.6 03/11/2005 01:10:00 12.8 1.4 17.2 9.9 12.8 1.5 17.9 8.8 0.4 0 0.4 0.4 26 5 29 305 28 0 28 0 -16.4 0 -16 -16.6 03/11/2005 01:20:00 13.5 1.4 17.2 9.5 13.3 1.5 17.2 9.5 0.4 0 0.4 0.4 26 5 29 305 28 0 28 0 -16.2 0.1 -16 -16.4 03/11/2005 01:30:00 13.7 1.4 17.6 9.9 13.4 1.4 17.2 10.3 0.4 0 0.4 0.4 24 5 24 305 28 0 28 0 -16.1 0 -15.6 -16.4 03/11/2005 01:40:00 13.7 1.4 17.2 9.9 13.6 1.4 16.8 9.9 0.4 0 0.4 0.4 26 5 28 305 28 0 28 0 -15.9 0.1 -15.6 -16.2 03/11/2005 01:50:00 13.5 1.4 17.2 9.9 13.2 1.3 16.1 9.9 0.4 0 0.4 0.4 25 6 29 305 29 0 28 0 -15.8 0.1 -15.4 -16 03/11/2005 02:00:00 14.6 1.6 17.9 10.7 14.3 1.6 18.7 9.9 0.4 0 0.4 0.4 24 5 21 305 29 0 28 0 -16.1 0.2 -15.6 -16.6 03/11/2005 02:10:00 14.8 1.4 18.7 11.1 14.7 1.4 17.9 11.1 0.4 0 0.4 0.4 23 5 23 305 29 0 29 0 -16.3 0.1 -15.8 -16.6 03/11/2005 02:20:00 14.1 1.5 17.9 10.3 14 1.5 17.6 10.3 0.4 0 0.4 0.4 23 6 17 305 28 0 28 0 -16.5 0.2 -16 -16.9 03/11/2005 02:30:00 14 1.6 17.6 10.3 13.9 1.7 17.6 10.3 0.4 0 0.4 0.4 22 5 29 305 28 0 28 0 -16.7 0.2 -16.2 -16.9 03/11/2005 02:40:00 14 1 16.4 10.7 13.8 1.1 16.8 10.3 0.4 0 0.4 0.4 25 5 25 305 28 0 28 0 -16.6 0.1 -16.2 -16.9 03/11/2005 02:50:00 15.1 1.6 19.5 11.1 14.9 1.7 19.5 10.7 0.4 0 0.4 0.4 23 5 27 305 27 0 27 0 -16.7 0.2 -16.2 -16.9 03/11/2005 03:00:00 15 1.5 19.1 10.3 14.8 1.4 18.3 10.7 0.4 0 0.4 0.4 21 5 25 305 27 0 27 0 -16.8 0.1 -16.4 -16.9 03/11/2005 03:10:00 14.1 1.5 18.7 10.7 14 1.6 17.9 10.3 0.4 0 0.4 0.4 18 6 18 305 27 0 27 0 -16.9 0 -16.6 -16.9 03/11/2005 03:20:00 13.3 1.4 16.8 10.3 13.2 1.4 17.2 10.3 0.4 0 0.4 0.4 18 6 17 305 27 0 27 0 -16.8 0.1 -16.4 -16.9 03/11/2005 03:30:00 14.7 1.4 17.6 11.1 14.7 1.5 17.6 10.3 0.4 0 0.4 0.4 18 5 15 305 27 0 26 0 -16.8 0.1 -16.4 -16.9 03/11/2005 03:40:00 15.1 1.5 18.3 10.7 14.9 1.6 18.7 10.3 0.4 0 0.4 0.4 19 5 13 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/11/2005 03:50:00 14.9 1.3 18.3 11.1 14.8 1.3 17.6 11.1 0.4 0 0.4 0.4 21 5 23 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/11/2005 04:00:00 14.9 1.6 19.5 11.1 14.8 1.5 19.1 11.1 0.4 0 0.4 0.4 20 5 15 305 26 0 26 0 -16.9 0 -16.4 -16.9 03/11/2005 04:10:00 13.5 1.5 17.9 9.9 13.3 1.5 17.9 9.9 0.4 0 0.4 0.4 18 6 26 305 26 0 26 0 -16.8 0 -16.4 -16.9 03/11/2005 04:20:00 15.3 1.5 17.9 11.5 15 1.6 18.3 10.7 0.4 0 0.4 0.4 19 5 20 305 26 0 27 0 -16.9 0 -16.6 -16.9 03/11/2005 04:30:00 13.6 1.2 16.8 10.7 13.6 1.2 17.2 10.3 0.4 0 0.4 0.4 18 5 18 305 26 0 26 0 -16.7 0.1 -16.4 -16.9 03/11/2005 04:40:00 14.1 1.3 17.2 10.3 14 1.3 17.2 9.9 0.4 0 0.4 0.4 20 5 22 305 26 0 26 0 -16.6 0 -16.4 -16.9 03/11/2005 04:50:00 14.5 1.7 17.9 10.3 14.5 1.6 18.3 10.7 0.4 0 0.4 0.4 18 5 20 305 27 0 27 0 -16.6 0 -16.2 -16.9 03/11/2005 05:00:00 14.2 1.7 17.9 9.9 14.1 1.7 17.6 9.5 0.4 0 0.4 0.4 19 5 25 305 27 0 27 0 -16.7 0.1 -16.2 -16.9 03/11/2005 05:10:00 15.1 1.5 17.9 10.3 15 1.5 17.9 9.9 0.4 0 0.4 0.4 16 4 19 305 27 0 27 0 -16.9 0 -16.4 -16.9 03/11/2005 05:20:00 13 1.2 16.4 9.5 13 1.2 16.8 9.5 0.4 0 0.4 0.4 20 5 19 305 27 0 27 0 -16.9 0 -16.4 -16.9 03/11/2005 05:30:00 14.2 1.3 17.2 10.7 14 1.3 17.2 10.7 0.4 0 0.4 0.4 19 4 20 305 26 0 26 0 -16.9 0 -16.4 -16.9 03/11/2005 05:40:00 13.6 1.2 16.4 11.1 13.4 1.3 16.1 10.3 0.4 0 0.4 0.4 20 5 25 305 26 0 27 0 -16.9 0 -16.4 -16.9 03/11/2005 05:50:00 13 1.2 15.6 9.9 12.8 1.2 16.4 8.8 0.4 0 0.4 0.4 19 5 12 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/11/2005 06:00:00 13.4 1.2 16.4 10.3 13.3 1.3 16.8 9.5 0.4 0 0.4 0.4 18 5 16 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/11/2005 06:10:00 13.1 1.5 16.8 8.8 13.1 1.5 16.4 8.8 0.4 0 0.4 0.4 20 5 22 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/11/2005 06:20:00 13 1.2 17.6 9.9 12.8 1.3 16.4 9.1 0.4 0 0.4 0.4 20 6 24 305 26 0 26 0 -16.8 0 -16.4 -16.9 03/11/2005 06:30:00 12.4 1.2 14.9 8.4 12.3 1.2 14.9 8.8 0.4 0 0.4 0.4 20 5 14 305 26 0 26 0 -17 0.1 -16.6 -17.3 03/11/2005 06:40:00 12.8 1.1 16.1 9.9 12.6 1.2 15.6 9.5 0.4 0 0.4 0.4 17 5 13 305 26 0 26 0 -17.3 0.1 -16.9 -17.5 03/11/2005 06:50:00 13.6 1.3 16.4 9.5 13.5 1.3 16.4 9.1 0.4 0 0.4 0.4 21 4 18 305 26 0 26 0 -17.4 0 -16.9 -17.5 03/11/2005 07:00:00 12.6 1.2 16.1 9.1 12.4 1.3 15.6 9.1 0.4 0 0.4 0.4 21 5 19 305 25 0 25 0 -17.4 0.1 -16.9 -17.5 03/11/2005 07:10:00 12.4 1.2 15.3 8.8 12.3 1.2 15.3 8.8 0.4 0 0.4 0.4 23 5 27 305 25 0 25 0 -17.3 0.1 -16.9 -17.5 03/11/2005 07:20:00 11.3 1.2 14.5 8 11.2 1.3 14.1 8.4 0.4 0 0.4 0.4 21 5 26 305 25 0 25 0 -17.3 0.1 -16.9 -17.5 03/11/2005 07:30:00 11.9 1 14.1 9.5 11.9 1 14.5 9.5 0.4 0 0.4 0.4 19 5 23 305 25 0 25 0 -17.3 0.1 -16.9 -17.5 03/11/2005 07:40:00 12.2 1.2 14.5 9.1 12.2 1.2 14.9 9.1 0.4 0 0.4 0.4 17 5 14 305 25 0 25 0 -17.2 0.1 -16.9 -17.3 03/11/2005 07:50:00 12 1.2 14.9 9.1 12 1.3 14.9 8.8 0.4 0 0.4 0.4 16 5 14 305 25 0 25 0 -17.2 0.1 -16.9 -17.3 03/11/2005 08:00:00 12.6 1.1 14.9 9.9 12.5 1.1 15.3 9.9 0.4 0 0.4 0.4 17 5 25 305 25 0 25 0 -17.2 0.1 -16.9 -17.5 03/11/2005 08:10:00 12.6 1.1 15.6 8.8 12.5 1.2 15.3 9.5 0.4 0 0.4 0.4 16 5 17 305 25 0 25 0 -17.2 0.2 -16.9 -17.5 03/11/2005 08:20:00 13 1.3 16.4 9.5 12.9 1.3 16.8 9.5 0.4 0 0.4 0.4 19 5 21 305 25 0 25 0 -17.3 0.2 -16.9 -17.5 03/11/2005 08:30:00 13.4 1.1 16.1 10.7 13.2 1.2 16.1 10.3 0.4 0 0.4 0.4 16 5 18 305 25 0 25 0 -17.5 0.2 -16.9 -17.9 03/11/2005 08:40:00 13.2 1.3 16.4 9.1 13.1 1.2 16.1 9.1 0.4 0 0.4 0.4 19 5 21 305 24 0 24 0 -17.9 0.1 -17.3 -18.1 03/11/2005 08:50:00 13.9 1.3 17.6 10.7 13.8 1.3 17.9 10.7 0.4 0 0.4 0.4 20 5 25 305 24 0 24 0 -18.1 0 -18.1 -18.2 03/11/2005 09:00:00 14.2 1.6 17.6 9.9 14 1.7 18.3 9.9 0.4 0 0.4 0.4 21 5 23 305 24 0 24 0 -18.2 0.1 -17.9 -18.4 03/11/2005 09:10:00 13.3 1.3 16.4 10.3 13.2 1.4 17.2 9.5 0.4 0 0.4 0.4 18 5 18 305 23 0 24 0 -18.4 0.1 -18.1 -18.4 03/11/2005 09:20:00 11.1 1.3 14.5 8 10.9 1.3 14.9 7.2 0.4 0 0.4 0.4 16 5 14 305 23 0 23 0 -18.2 0 -17.9 -18.4 03/11/2005 09:30:00 11.9 1.5 14.9 7.6 11.8 1.5 15.3 8.8 0.4 0 0.4 0.4 18 5 17 305 23 0 23 0 -18.1 0 -17.7 -18.2 03/11/2005 09:40:00 12.2 1.3 15.3 9.5 12.1 1.3 15.6 9.1 0.4 0 0.4 0.4 20 5 23 305 23 0 23 0 -18 0 -17.5 -18.1 03/11/2005 09:50:00 12.1 1.2 15.3 8.8 12 1.3 15.6 8 0.4 0 0.4 0.4 20 6 19 305 23 0 23 0 -17.8 0.1 -17.3 -18.1 03/11/2005 10:00:00 11.3 1 13.7 7.6 11.4 1.1 13.7 8.4 0.4 0 0.4 0.4 21 5 18 305 23 0 24 0 -17.5 0 -17.1 -17.7 03/11/2005 10:10:00 11.4 1.1 14.1 9.1 11.3 1.2 14.5 8.4 0.4 0 0.4 0.4 19 5 17 305 24 0 24 0 -17.5 0 -17.3 -17.7 03/11/2005 10:20:00 10.7 1 13 8.4 10.7 1 13.3 8.8 0.4 0 0.4 0.4 17 4 19 305 24 0 24 0 -17.4 0 -17.1 -17.5 03/11/2005 10:30:00 11.7 1.8 17.9 8.4 11.5 1.7 16.8 8.8 0.4 0 0.4 0.4 15 7 18 305 24 0 24 0 -17.4 0.2 -16.9 -17.9 03/11/2005 10:40:00 12.5 1.2 15.3 9.1 12.4 1.2 16.1 8.8 0.4 0 0.4 0.4 13 5 10 305 25 0 25 0 -17.8 0.1 -17.5 -18.1 03/11/2005 10:50:00 11.8 1.1 14.9 8.8 11.7 1.2 15.3 8.4 0.4 0 0.4 0.4 17 5 17 305 25 0 25 0 -17.9 0.1 -17.5 -18.1 03/11/2005 11:00:00 12.9 1.2 15.6 9.5 12.8 1.2 15.6 9.5 0.4 0 0.4 0.4 19 5 17 305 24 0 24 0 -18 0 -17.7 -18.1 03/11/2005 11:10:00 13.4 1.1 16.1 10.3 13.2 1.2 16.1 9.5 0.4 0 0.4 0.4 18 5 14 305 24 0 24 0 -18 0 -17.7 -18.1 03/11/2005 11:20:00 12.4 1.3 15.6 8.8 12.3 1.3 15.6 8.8 0.4 0 0.4 0.4 18 5 11 305 24 0 24 0 -18.1 0 -17.7 -18.2 03/11/2005 11:30:00 11.9 1.3 15.6 8.8 11.8 1.3 14.9 9.1 0.4 0 0.4 0.4 19 5 30 305 24 0 25 0 -18.1 0 -17.7 -18.2 03/11/2005 11:40:00 13 1.5 16.4 9.1 12.9 1.5 16.1 9.5 0.4 0 0.4 0.4 19 5 17 305 25 0 25 0 -18.1 0 -17.7 -18.2 03/11/2005 11:50:00 11.3 1.3 14.1 8 11.3 1.4 14.5 7.2 0.4 0 0.4 0.4 21 5 15 305 25 0 25 0 -18 0 -17.5 -18.1 03/11/2005 12:00:00 12 1.1 14.9 9.1 11.9 1.2 14.9 8.4 0.4 0 0.4 0.4 20 5 21 305 25 0 25 0 -17.9 0.1 -17.5 -18.1 03/11/2005 12:10:00 11.8 1.1 14.5 9.1 11.8 1.1 14.9 9.1 0.4 0 0.4 0.4 20 5 23 305 25 0 25 0 -17.7 0.1 -17.1 -17.9 03/11/2005 12:20:00 11.7 1.1 14.5 9.1 11.7 1.2 14.9 9.1 0.4 0 0.4 0.4 24 5 23 305 26 0 26 0 -17.5 0.1 -16.9 -17.7 03/11/2005 12:30:00 13.2 1.1 15.6 10.3 12.9 1.2 15.6 9.5 0.4 0 0.4 0.4 24 5 20 305 27 0 27 0 -17.3 0.1 -16.9 -17.5 03/11/2005 12:40:00 12.9 1 15.3 10.3 12.8 1.2 15.6 9.1 0.4 0 0.4 0.4 26 4 25 305 27 0 27 0 -17 0.1 -16.6 -17.3 03/11/2005 12:50:00 12.1 1.3 15.6 8.4 11.9 1.4 14.9 8.4 0.4 0 0.4 0.4 23 5 24 305 28 0 28 0 -16.9 0.1 -16.4 -16.9 03/11/2005 13:00:00 11.4 1.1 13.7 8.4 11.2 1.1 13.7 8.8 0.4 0 0.4 0.4 19 6 15 305 29 0 28 0 -16.9 0.1 -16.4 -17.3 03/11/2005 13:10:00 11.5 1.2 14.5 9.1 11.3 1.3 14.1 8.4 0.4 0 0.4 0.4 19 5 24 305 29 0 29 0 -16.9 0 -16.4 -16.9 03/11/2005 13:20:00 11.8 1.2 14.5 8.8 11.6 1.2 14.1 9.1 0.4 0 0.4 0.4 18 5 20 305 30 0 30 0 -17.1 0.2 -16.6 -17.5 03/11/2005 13:30:00 12 1 14.5 9.5 12 1 14.9 9.1 0.4 0 0.4 0.4 18 5 18 305 30 0 29 0 -17.4 0.1 -16.9 -17.7 03/11/2005 13:40:00 12.4 1 14.9 9.5 12.3 1.1 15.3 9.5 0.4 0 0.4 0.4 20 5 18 305 29 0 30 0 -17.6 0.1 -16.9 -17.9 03/11/2005 13:50:00 11.9 0.9 14.5 9.5 11.8 1 14.5 9.1 0.4 0 0.4 0.4 20 5 19 305 29 0 29 0 -17.5 0.1 -16.9 -17.9 03/11/2005 14:00:00 11.5 1.1 14.5 9.1 11.3 1.1 14.5 8.8 0.4 0 0.4 0.4 20 5 25 305 29 0 29 0 -17.6 0.1 -17.1 -17.9 03/11/2005 14:10:00 12.3 1.2 16.1 9.5 12.1 1.3 15.6 8.8 0.4 0 0.4 0.4 20 4 21 305 29 0 29 0 -17.6 0.1 -16.9 -17.9 03/11/2005 14:20:00 12.5 1.1 14.9 9.1 12.4 1.1 15.3 9.1 0.4 0 0.4 0.4 19 5 22 305 28 0 28 0 -17.5 0 -16.9 -17.5 03/11/2005 14:30:00 12.7 1.1 15.3 9.9 12.7 1.1 15.3 9.9 0.4 0 0.4 0.4 19 4 16 305 28 0 28 0 -17.4 0.1 -16.9 -17.5 03/11/2005 14:40:00 12.7 1.1 15.3 10.3 12.7 1.1 15.6 9.9 0.4 0 0.4 0.4 18 5 22 305 29 0 28 0 -17.2 0.1 -16.6 -17.5 03/11/2005 14:50:00 12.6 1 14.9 9.9 12.5 1 14.9 9.5 0.4 0 0.4 0.4 18 4 13 305 29 0 29 0 -17 0.1 -16.6 -17.3 03/11/2005 15:00:00 13.3 1 15.6 10.3 13.1 1 15.3 10.3 0.4 0 0.4 0.4 18 4 16 305 30 0 29 0 -16.9 0 -16.4 -16.9 03/11/2005 15:10:00 13.1 1.1 14.9 9.1 13 1.1 15.6 9.1 0.4 0 0.4 0.4 17 4 14 305 30 0 30 0 -16.9 0 -16.4 -16.9 03/11/2005 15:20:00 12.3 1 14.9 9.5 12.2 1.1 14.5 9.5 0.4 0 0.4 0.4 16 4 15 305 30 0 30 0 -16.8 0.1 -16.4 -16.9 03/11/2005 15:30:00 11.9 1 14.5 9.5 11.7 1 14.9 9.1 0.4 0 0.4 0.4 18 4 14 305 31 0 31 0 -16.7 0.2 -16.2 -16.9 03/11/2005 15:40:00 13 1.2 15.6 9.5 12.9 1.3 15.6 9.1 0.4 0 0.4 0.4 17 5 15 305 31 0 31 0 -16.6 0.1 -16 -16.9 03/11/2005 15:50:00 13 1 15.3 10.3 12.9 1.1 15.3 9.9 0.4 0 0.4 0.4 18 4 14 305 31 0 32 0 -16.6 0.2 -16 -16.9 03/11/2005 16:00:00 11.8 1 14.5 8.8 11.7 1 13.7 9.1 0.4 0 0.4 0.4 20 5 22 305 32 0 31 0 -16.6 0.2 -16 -16.9 03/11/2005 16:10:00 12.6 1 15.3 9.5 12.4 1.1 15.3 9.5 0.4 0 0.4 0.4 25 4 15 305 32 0 32 0 -16.5 0.1 -16 -16.9 03/11/2005 16:20:00 12 0.8 14.1 9.9 11.8 0.9 14.5 9.5 0.4 0 0.4 0.4 26 5 19 305 32 0 32 0 -16.3 0.1 -15.8 -16.6 03/11/2005 16:30:00 12.8 0.9 14.9 10.3 12.5 1 14.9 9.9 0.4 0 0.4 0.4 27 4 27 305 33 0 33 0 -16.3 0.1 -15.8 -16.6 03/11/2005 16:40:00 14.5 1.5 17.9 10.7 14.2 1.5 17.9 10.7 0.4 0 0.4 0.4 35 5 33 305 33 0 33 0 -16 0.2 -15.6 -16.4 03/11/2005 16:50:00 14.2 1.1 17.6 10.3 13.9 1.1 16.4 11.1 0.4 0 0.4 0.4 36 6 39 305 33 0 33 0 -16 0.2 -15.6 -16.4 03/11/2005 17:00:00 14.3 1.2 17.2 11.5 14 1.2 16.8 10.7 0.4 0 0.4 0.4 38 5 42 305 33 0 33 0 -16.1 0.2 -15.6 -16.4 03/11/2005 17:10:00 14.2 1.3 17.6 11.1 13.9 1.3 17.2 10.3 0.4 0 0.4 0.4 34 4 29 305 32 0 32 0 -16.1 0.1 -15.6 -16.4 03/11/2005 17:20:00 13.4 1.2 16.4 9.5 13.1 1.2 15.6 10.3 0.4 0 0.4 0.4 35 5 26 305 32 0 32 0 -16 0.1 -15.6 -16.2 03/11/2005 17:30:00 12.7 1.2 15.3 9.5 12.4 1.2 15.3 9.5 0.4 0 0.4 0.4 35 5 27 305 32 0 32 0 -15.9 0.1 -15.6 -16.2 03/11/2005 17:40:00 14.2 1.1 16.8 11.1 14 1.2 16.4 10.3 0.4 0 0.4 0.4 36 5 36 305 32 0 32 0 -16.1 0.1 -15.6 -16.4 03/11/2005 17:50:00 12.9 1.2 15.6 9.9 12.6 1.2 15.3 9.9 0.4 0 0.4 0.4 33 5 42 305 32 0 32 0 -16.2 0.1 -15.6 -16.4 03/11/2005 18:00:00 12.4 1 14.5 9.1 12.3 1 14.9 9.5 0.4 0 0.4 0.4 19 7 23 305 32 0 32 0 -16.6 0.3 -15.6 -16.9 03/11/2005 18:10:00 12.8 1 15.3 10.3 12.7 1 15.3 10.3 0.4 0 0.4 0.4 18 4 19 305 32 0 32 0 -17 0 -16.6 -17.1 03/11/2005 18:20:00 13.5 1 16.1 10.7 13.3 1 16.4 10.7 0.4 0 0.4 0.4 24 5 24 305 31 0 31 0 -17 0 -16.6 -17.3 03/11/2005 18:30:00 13.1 1.2 16.1 9.9 12.8 1.2 15.6 9.5 0.4 0 0.4 0.4 26 4 29 305 30 0 31 0 -16.9 0 -16.4 -17.1 03/11/2005 18:40:00 11.8 1 13.7 9.1 11.7 1 13.7 8.4 0.4 0 0.4 0.4 24 5 24 305 29 0 29 0 -16.9 0 -16.4 -16.9 03/11/2005 18:50:00 11.9 1 14.1 9.9 11.8 1 14.1 9.5 0.4 0 0.4 0.4 26 5 29 305 29 0 29 0 -16.7 0.1 -16 -16.9 03/11/2005 19:00:00 12.2 1.4 16.8 8.8 12 1.4 15.6 8.4 0.4 0 0.4 0.4 32 5 44 305 29 0 29 0 -16.4 0.1 -15.8 -16.6 03/11/2005 19:10:00 13.6 1.3 17.2 10.3 13.3 1.4 17.2 9.5 0.4 0 0.4 0.4 32 5 30 305 29 0 29 0 -16.4 0 -15.8 -16.6 03/11/2005 19:20:00 13.3 1.3 16.1 9.9 13 1.3 16.4 9.5 0.4 0 0.4 0.4 32 5 27 305 28 0 28 0 -16.4 0 -16 -16.6 03/11/2005 19:30:00 13.2 1 16.1 11.1 13 1.1 16.4 10.7 0.4 0 0.4 0.4 32 5 28 305 28 0 28 0 -16.4 0 -16 -16.6 03/11/2005 19:40:00 13.8 0.9 16.1 10.7 13.5 1 15.6 10.3 0.4 0 0.4 0.4 30 4 33 305 28 0 28 0 -16.5 0.1 -16 -16.9 03/11/2005 19:50:00 12.8 1 15.3 9.5 12.5 1 15.6 9.9 0.4 0 0.4 0.4 31 5 31 305 28 0 28 0 -16.6 0.1 -16 -16.9 03/11/2005 20:00:00 12.3 1 14.5 9.9 12.1 1 14.9 9.5 0.4 0 0.4 0.4 33 4 38 305 28 0 28 0 -16.4 0.1 -16 -16.7 03/11/2005 20:10:00 11.9 1 14.5 9.1 11.7 1.1 14.5 9.1 0.4 0 0.4 0.4 29 5 29 305 27 0 27 0 -16.5 0.2 -16 -16.9 03/11/2005 20:20:00 12.1 1 14.5 9.9 11.8 1 14.5 9.5 0.4 0 0.4 0.4 29 5 30 305 27 0 27 0 -16.7 0.2 -16.2 -16.9 03/11/2005 20:30:00 12.2 0.9 14.5 10.3 12 1 14.1 9.5 0.4 0 0.4 0.4 31 4 31 305 27 0 27 0 -16.7 0.2 -16.2 -16.9 03/11/2005 20:40:00 11.6 1 14.5 8.8 11.3 1 13.7 8 0.4 0 0.4 0.4 31 5 35 305 27 0 27 0 -16.6 0.2 -16 -16.9 03/11/2005 20:50:00 11.3 1 13.7 8.8 11.1 1 13.7 8.8 0.4 0 0.4 0.4 33 4 30 305 27 0 27 0 -16.6 0.1 -16 -16.9 03/11/2005 21:00:00 10.9 1 13 8 10.8 0.9 13 8 0.4 0 0.4 0.4 29 4 32 305 27 0 27 0 -16.6 0.1 -16.2 -16.9 03/11/2005 21:10:00 11.2 0.7 13.3 9.1 11 0.7 13.3 9.1 0.4 0 0.4 0.4 30 3 33 305 27 0 27 0 -16.7 0.1 -16.2 -16.9 03/11/2005 21:20:00 9.6 1.1 12.2 6.8 9.5 1.2 12.6 6.5 0.4 0 0.4 0.4 30 5 30 305 26 0 27 0 -16.6 0.1 -16.2 -16.9 03/11/2005 21:30:00 10.1 1.1 12.2 7.2 9.9 1.1 12.6 7.2 0.4 0 0.4 0.4 30 5 29 305 26 0 26 0 -16.6 0.1 -16.2 -16.9 03/11/2005 21:40:00 11.4 0.8 13.3 9.5 11.1 0.9 13.7 8.8 0.4 0 0.4 0.4 29 4 27 305 26 0 26 0 -16.6 0.1 -16.2 -16.9 03/11/2005 21:50:00 10.5 1.1 13.3 7.6 10.3 1 13 8 0.4 0 0.4 0.4 32 5 33 305 26 0 26 0 -16.6 0.1 -16.2 -16.9 03/11/2005 22:00:00 10.2 1.1 13 7.2 10.1 1.1 13 7.2 0.4 0 0.4 0.4 33 5 29 305 26 0 26 0 -16.7 0.1 -16.2 -16.9 03/11/2005 22:10:00 10.5 1.1 12.6 7.2 10.3 1 12.2 7.2 0.4 0 0.4 0.4 31 4 29 305 26 0 26 0 -16.7 0.1 -16.2 -16.9 03/11/2005 22:20:00 9.8 1.1 13 7.2 9.6 1.1 13 6.8 0.4 0 0.4 0.4 32 5 27 305 26 0 26 0 -16.8 0.1 -16.2 -16.9 03/11/2005 22:30:00 10 1 11.8 7.2 9.7 1 12.2 6.8 0.4 0 0.4 0.4 32 5 33 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/11/2005 22:40:00 9.9 1.1 12.6 7.2 9.5 1.2 12.2 6.5 0.4 0 0.4 0.4 31 5 35 305 26 0 26 0 -16.7 0.1 -16.2 -16.9 03/11/2005 22:50:00 10.5 0.9 12.6 7.6 10.3 1 12.6 7.2 0.4 0 0.4 0.4 26 5 26 305 26 0 26 0 -16.7 0.1 -16.2 -16.9 03/11/2005 23:00:00 9.7 1 11.8 7.2 9.5 1 11.5 6.8 0.4 0 0.4 0.4 26 5 22 305 26 0 26 0 -16.7 0.1 -16.2 -16.9 03/11/2005 23:10:00 9.8 1.1 13 7.2 9.6 1.2 12.2 6.5 0.4 0 0.4 0.4 27 5 25 305 26 0 26 0 -16.7 0.1 -16.2 -16.9 03/11/2005 23:20:00 9.6 1 12.2 7.2 9.3 1 11.8 6.8 0.4 0 0.4 0.4 28 6 39 305 26 0 26 0 -16.7 0.1 -16.2 -16.9 03/11/2005 23:30:00 10.4 1 12.6 7.6 10.2 1.1 12.6 7.6 0.4 0 0.4 0.4 28 5 27 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/11/2005 23:40:00 10.8 1.1 13.3 8 10.6 1.2 13 8 0.4 0 0.4 0.4 29 5 27 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/11/2005 23:50:00 11.4 0.9 13.3 9.1 11.3 1 13.3 9.1 0.4 0 0.4 0.4 27 5 22 305 26 0 26 0 -16.9 0 -16.4 -16.9 03/12/2005 00:00:00 11.5 1.1 14.1 8 11.3 1.2 13.7 8.4 0.4 0 0.4 0.4 31 5 27 305 26 0 26 0 -16.9 0 -16.4 -16.9 03/12/2005 00:10:00 10.6 1.3 13.3 7.6 10.4 1.3 13.3 6.8 0.4 0 0.4 0.4 28 6 36 305 26 0 26 0 -16.9 0 -16.6 -17.1 03/12/2005 00:20:00 10.8 1.1 13 7.2 10.6 1.1 13 7.2 0.4 0 0.4 0.4 30 5 30 305 26 0 26 0 -16.9 0 -16.4 -16.9 03/12/2005 00:30:00 10.3 0.9 12.6 7.6 10.1 1 12.6 8 0.4 0 0.4 0.4 31 5 33 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/12/2005 00:40:00 10 0.9 12.2 7.6 9.8 0.9 12.6 7.6 0.4 0 0.4 0.4 28 5 22 305 26 0 26 0 -16.8 0.2 -16.4 -16.9 03/12/2005 00:50:00 10.3 0.8 12.6 7.6 10.3 0.9 12.2 8.4 0.4 0 0.4 0.4 27 6 39 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/12/2005 01:00:00 10.1 1.1 13 7.6 9.9 1.1 12.2 7.6 0.4 0 0.4 0.4 28 5 35 305 26 0 26 0 -16.8 0.2 -16.4 -16.9 03/12/2005 01:10:00 9.7 0.9 11.5 7.2 9.6 0.9 11.8 7.2 0.4 0 0.4 0.4 28 6 28 305 26 0 26 0 -16.8 0.2 -16.4 -16.9 03/12/2005 01:20:00 10.3 0.8 12.2 7.6 10 0.8 11.8 7.2 0.4 0 0.4 0.4 28 6 27 305 26 0 26 0 -16.7 0.2 -16.4 -16.9 03/12/2005 01:30:00 8.9 0.8 11.1 6.5 8.7 0.9 10.7 6.5 0.4 0 0.4 0.4 29 6 24 305 26 0 26 0 -16.8 0.2 -16.4 -16.9 03/12/2005 01:40:00 9.3 1.1 11.8 6.8 9 1.2 12.2 6.5 0.4 0 0.4 0.4 27 6 29 305 26 0 26 0 -16.7 0.2 -16.4 -16.9 03/12/2005 01:50:00 9.4 1 11.8 6.8 9.4 1.1 11.8 6.5 0.4 0 0.4 0.4 24 5 21 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/12/2005 02:00:00 9.7 1 11.8 6.5 9.5 1 11.8 6.8 0.4 0 0.4 0.4 25 5 22 305 26 0 26 0 -16.8 0.2 -16.4 -16.9 03/12/2005 02:10:00 9.4 1 11.8 6.8 9.2 1 12.2 6.8 0.4 0 0.4 0.4 26 6 28 305 26 0 26 0 -16.8 0.2 -16.4 -16.9 03/12/2005 02:20:00 9.4 0.9 11.5 7.2 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 30 6 31 305 26 0 26 0 -16.8 0.2 -16.4 -16.9 03/12/2005 02:30:00 9.9 1 11.8 6.8 9.6 1 11.8 6.5 0.4 0 0.4 0.4 31 5 31 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/12/2005 02:40:00 10 1.2 12.2 6.8 9.7 1.2 12.2 6.8 0.4 0 0.4 0.4 34 6 35 305 26 0 26 0 -16.8 0.1 -16.4 -16.9 03/12/2005 02:50:00 10.5 1.5 13.3 7.2 10.2 1.4 13 7.2 0.4 0 0.4 0.4 31 5 27 305 26 0 26 0 -16.9 0 -16.4 -16.9 03/12/2005 03:00:00 10.3 1 12.6 7.6 10 1 12.2 7.2 0.4 0 0.4 0.4 29 6 25 305 25 0 26 0 -16.9 0 -16.6 -16.9 03/12/2005 03:10:00 9.9 1 13 6.5 9.8 1.1 13 6.8 0.4 0 0.4 0.4 30 6 25 305 25 0 25 0 -16.9 0 -16.6 -17.1 03/12/2005 03:20:00 10.7 1.3 13.3 6.8 10.5 1.4 13 6.8 0.4 0 0.4 0.4 29 6 29 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 03:30:00 11 1.3 13.7 8 10.8 1.3 13.3 7.6 0.4 0 0.4 0.4 32 5 29 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 03:40:00 11.1 1.3 14.1 8.4 10.8 1.3 14.1 8 0.4 0 0.4 0.4 29 5 33 305 25 0 25 0 -17.1 0.1 -16.6 -17.3 03/12/2005 03:50:00 11.9 0.8 13.7 9.5 11.6 0.9 13.7 9.5 0.4 0 0.4 0.4 34 5 32 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 04:00:00 12 0.9 14.5 9.1 11.7 1 14.5 9.1 0.4 0 0.4 0.4 33 4 32 305 25 0 25 0 -17.1 0 -16.9 -17.3 03/12/2005 04:10:00 12.1 1.1 14.9 9.1 11.8 1.1 14.5 9.1 0.4 0 0.4 0.4 31 5 30 305 25 0 25 0 -17.1 0 -16.9 -17.3 03/12/2005 04:20:00 11.6 1 14.1 8.4 11.4 1.1 13.7 8.4 0.4 0 0.4 0.4 35 5 39 305 25 0 25 0 -17.1 0 -16.9 -17.3 03/12/2005 04:30:00 12.1 1 14.5 9.5 11.9 1.1 14.1 8.8 0.4 0 0.4 0.4 41 5 43 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 04:40:00 12.4 0.9 14.1 9.1 12 1 14.1 9.1 0.4 0 0.4 0.4 39 4 38 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 04:50:00 12.8 1.2 16.1 9.5 12.5 1.2 15.6 9.1 0.4 0 0.4 0.4 37 5 37 305 25 0 25 0 -17.2 0 -16.9 -17.3 03/12/2005 05:00:00 11.6 1.3 14.1 8.4 11.3 1.4 14.9 8 0.4 0 0.4 0.4 35 5 38 305 25 0 25 0 -17.2 0.1 -16.9 -17.3 03/12/2005 05:10:00 11 1.1 14.1 8.4 10.7 1.1 13.7 8.4 0.4 0 0.4 0.4 37 6 33 305 25 0 25 0 -17.2 0 -16.9 -17.3 03/12/2005 05:20:00 11.5 1 14.1 8.4 11.1 1 14.1 8 0.4 0 0.4 0.4 31 5 32 305 25 0 25 0 -17.1 0 -16.9 -17.3 03/12/2005 05:30:00 11.6 1.1 14.5 9.1 11.3 1.1 14.1 8.4 0.4 0 0.4 0.4 33 5 35 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 05:40:00 11.3 1.2 14.1 8.4 11.1 1 13.3 8 0.4 0 0.4 0.4 32 6 34 305 25 0 25 0 -17.1 0 -16.9 -17.3 03/12/2005 05:50:00 11.9 1.3 14.1 8.4 11.5 1.3 14.1 8.4 0.4 0 0.4 0.4 30 4 29 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 06:00:00 12.2 1 14.5 9.5 11.8 1.1 14.1 9.1 0.4 0 0.4 0.4 34 4 32 305 25 0 25 0 -17.2 0.1 -16.9 -17.5 03/12/2005 06:10:00 11.6 1.2 14.1 8.4 11.3 1.2 14.1 8.4 0.4 0 0.4 0.4 35 5 38 305 25 0 25 0 -17.2 0.1 -16.9 -17.3 03/12/2005 06:20:00 12.4 1.1 15.6 9.1 12.1 1.1 14.9 9.1 0.4 0 0.4 0.4 33 5 25 305 24 0 25 0 -17.2 0.1 -16.9 -17.5 03/12/2005 06:30:00 11.9 1.1 14.1 9.1 11.6 1.2 14.1 8.8 0.4 0 0.4 0.4 34 4 31 305 24 0 25 0 -17.3 0.1 -16.9 -17.3 03/12/2005 06:40:00 11 1.2 13.7 8 10.7 1.2 13.3 7.6 0.4 0 0.4 0.4 28 5 27 305 24 0 25 0 -17.2 0.1 -16.9 -17.5 03/12/2005 06:50:00 12 1 14.5 8.8 11.7 1.1 14.9 8.4 0.4 0 0.4 0.4 31 4 27 305 24 0 24 0 -17.2 0.1 -16.9 -17.5 03/12/2005 07:00:00 12.2 1.1 14.5 9.5 11.9 1.1 14.5 8.8 0.4 0 0.4 0.4 32 5 29 305 24 0 25 0 -17.2 0.1 -16.9 -17.3 03/12/2005 07:10:00 11.8 1 13.7 9.1 11.5 1.1 13.7 8.8 0.4 0 0.4 0.4 38 5 31 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 07:20:00 11.9 1.4 15.3 8.8 11.5 1.5 14.9 8.4 0.4 0 0.4 0.4 37 6 47 305 25 0 25 0 -17.1 0.1 -16.6 -17.3 03/12/2005 07:30:00 12 1.3 14.9 8.8 11.7 1.4 15.3 8.4 0.4 0 0.4 0.4 34 6 44 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 07:40:00 11.3 1.2 14.1 8 10.9 1.3 13.7 7.6 0.4 0 0.4 0.4 34 5 33 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 07:50:00 12.4 1.3 14.9 9.1 12.1 1.3 15.3 8.8 0.4 0 0.4 0.4 31 5 32 305 25 0 25 0 -17.2 0.1 -16.6 -17.3 03/12/2005 08:00:00 11 1.2 13.3 7.2 10.6 1.3 13.3 7.2 0.4 0 0.4 0.4 31 6 31 305 25 0 25 0 -17.2 0 -16.9 -17.3 03/12/2005 08:10:00 11 1 13.3 8.4 10.7 1 13.3 7.6 0.4 0 0.4 0.4 29 6 36 305 25 0 25 0 -17.2 0 -16.9 -17.3 03/12/2005 08:20:00 10.6 1 12.6 8 10.3 1 12.6 7.2 0.4 0 0.4 0.4 30 6 28 305 25 0 25 0 -17.2 0 -16.9 -17.5 03/12/2005 08:30:00 10.5 1 13.3 7.6 10.2 1 13.7 7.2 0.4 0 0.4 0.4 30 6 38 305 25 0 25 0 -17.2 0 -16.9 -17.3 03/12/2005 08:40:00 11 1.2 13.7 8 10.8 1.2 13.7 8 0.4 0 0.4 0.4 26 5 22 305 25 0 25 0 -17.2 0 -16.9 -17.3 03/12/2005 08:50:00 11.8 1 14.1 9.5 11.5 1 13.7 8.8 0.4 0 0.4 0.4 34 6 45 305 25 0 25 0 -17.2 0 -16.9 -17.3 03/12/2005 09:00:00 11.2 1.2 14.1 8.4 10.9 1.2 14.1 8 0.4 0 0.4 0.4 31 6 38 305 25 0 25 0 -17.2 0 -16.6 -17.3 03/12/2005 09:10:00 12.6 1 14.5 9.9 12.4 1 14.9 9.5 0.4 0 0.4 0.4 32 5 31 305 25 0 25 0 -17.2 0 -16.6 -17.5 03/12/2005 09:20:00 12.9 1.1 15.3 9.5 12.6 1.2 14.9 8.8 0.4 0 0.4 0.4 33 5 29 305 25 0 25 0 -17.2 0 -16.9 -17.3 03/12/2005 09:30:00 12.4 0.9 14.1 9.9 12.1 1 14.9 9.1 0.4 0 0.4 0.4 29 4 29 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 09:40:00 13.3 1 15.6 10.3 13 1.1 15.6 10.3 0.4 0 0.4 0.4 33 5 29 305 25 0 25 0 -17.1 0 -16.6 -17.3 03/12/2005 09:50:00 14.6 1 17.2 12.2 14.3 1 16.4 11.5 0.4 0 0.4 0.4 35 4 36 305 25 0 25 0 -17.2 0.1 -16.9 -17.3 03/12/2005 10:00:00 14.7 1.1 17.6 10.7 14.3 1.2 16.8 11.1 0.4 0 0.4 0.4 33 4 34 305 25 0 25 0 -17.2 0.1 -16.9 -17.3 03/12/2005 10:10:00 12.3 1.5 16.1 9.1 12.1 1.6 15.6 8.8 0.4 0 0.4 0.4 34 5 31 305 25 0 25 0 -17.1 0.1 -16.6 -17.3 03/12/2005 10:20:00 11.7 1.3 15.3 8 11.3 1.3 14.1 8 0.4 0 0.4 0.4 29 5 32 305 25 0 25 0 -17 0.1 -16.6 -17.3 03/12/2005 10:30:00 12.3 1.2 15.3 9.5 12.1 1.2 14.9 9.1 0.4 0 0.4 0.4 27 5 30 305 25 0 25 0 -17.2 0.1 -16.9 -17.5 03/12/2005 10:40:00 11.8 1 14.1 9.1 11.5 1 14.1 9.1 0.4 0 0.4 0.4 35 5 29 305 25 0 25 0 -17.1 0.1 -16.6 -17.3 03/12/2005 10:50:00 12 1.3 14.5 8.8 11.7 1.3 14.5 8.4 0.4 0 0.4 0.4 31 5 31 305 25 0 26 0 -17 0.1 -16.6 -17.3 03/12/2005 11:00:00 12.3 1 15.3 9.9 12.1 1 14.5 9.9 0.4 0 0.4 0.4 31 4 30 305 26 0 26 0 -17 0.1 -16.6 -17.1 03/12/2005 11:10:00 12.6 1.4 15.3 9.1 12.3 1.4 15.3 8 0.4 0 0.4 0.4 31 5 34 305 26 0 26 0 -17 0 -16.6 -17.3 03/12/2005 11:20:00 12.8 1.2 16.4 9.9 12.6 1.2 15.3 9.5 0.4 0 0.4 0.4 34 5 30 305 26 0 26 0 -17 0.1 -16.6 -17.3 03/12/2005 11:30:00 12.9 1 15.3 9.5 12.5 1.2 15.3 9.5 0.4 0 0.4 0.4 31 5 31 305 26 0 26 0 -17.2 0 -16.9 -17.3 03/12/2005 11:40:00 13 1.1 15.6 10.3 12.7 1.2 15.6 9.5 0.4 0 0.4 0.4 28 5 32 305 26 0 26 0 -17.1 0 -16.9 -17.3 03/12/2005 11:50:00 13.1 1.1 15.6 10.3 12.8 1.1 15.6 10.3 0.4 0 0.4 0.4 30 5 35 305 26 0 27 0 -17.1 0.1 -16.6 -17.3 03/12/2005 12:00:00 12.8 1.2 15.6 9.9 12.5 1.2 15.3 9.1 0.4 0 0.4 0.4 29 4 31 305 27 0 27 0 -17.1 0.1 -16.6 -17.3 03/12/2005 12:10:00 13.7 1.2 16.1 10.3 13.3 1.2 16.1 9.9 0.4 0 0.4 0.4 31 6 20 305 27 0 27 0 -17.3 0.1 -16.9 -17.5 03/12/2005 12:20:00 12.7 1.5 16.4 9.9 12.4 1.4 16.4 9.9 0.4 0 0.4 0.4 33 6 31 305 27 0 27 0 -17 0 -16.6 -17.3 03/12/2005 12:30:00 13.9 1.5 18.3 9.9 13.6 1.5 17.2 10.3 0.4 0 0.4 0.4 36 5 41 305 28 0 27 0 -17 0.1 -16.4 -17.1 03/12/2005 12:40:00 14.8 1.3 17.6 10.7 14.5 1.4 17.6 10.3 0.4 0 0.4 0.4 32 5 33 305 28 0 28 0 -17 0 -16.6 -17.1 03/12/2005 12:50:00 14.7 1.7 18.3 10.3 14.3 1.8 18.3 10.3 0.4 0 0.4 0.4 33 5 33 305 28 0 28 0 -17.1 0.1 -16.6 -17.3 03/12/2005 13:00:00 14.1 1 16.4 10.7 13.8 1.1 16.8 9.5 0.4 0 0.4 0.4 34 5 31 305 28 0 28 0 -17.1 0.1 -16.6 -17.3 03/12/2005 13:10:00 14.8 1.1 17.2 11.8 14.7 1.1 17.2 11.1 0.4 0 0.4 0.4 34 5 30 305 28 0 28 0 -17 0 -16.6 -17.3 03/12/2005 13:20:00 12.9 1.3 16.1 9.1 12.7 1.2 16.1 9.5 0.4 0 0.4 0.4 30 6 29 305 28 0 28 0 -16.9 0 -16.4 -17.1 03/12/2005 13:30:00 14.3 1 16.8 11.5 14 1.1 16.8 10.3 0.4 0 0.4 0.4 27 5 25 305 28 0 28 0 -17.1 0.1 -16.6 -17.3 03/12/2005 13:40:00 13.5 1.5 16.4 9.9 13.2 1.3 16.4 9.9 0.4 0 0.4 0.4 30 5 29 305 28 0 28 0 -17.1 0 -16.6 -17.3 03/12/2005 13:50:00 14.1 1.2 16.8 10.7 13.8 1.3 16.4 9.9 0.4 0 0.4 0.4 28 5 33 305 28 0 28 0 -17.1 0.1 -16.6 -17.3 03/12/2005 14:00:00 14.2 1.1 16.8 10.3 13.9 1.2 16.8 10.3 0.4 0 0.4 0.4 28 5 20 305 28 0 28 0 -17.1 0.1 -16.6 -17.3 03/12/2005 14:10:00 14.8 1.2 17.6 11.1 14.4 1.2 17.6 11.1 0.4 0 0.4 0.4 28 5 34 305 28 0 28 0 -17.2 0.1 -16.9 -17.3 03/12/2005 14:20:00 14.6 1.1 17.6 11.1 14.4 1.2 17.9 11.1 0.4 0 0.4 0.4 25 5 22 305 28 0 28 0 -17 0 -16.6 -17.3 03/12/2005 14:30:00 14.2 1.1 16.8 11.8 13.9 1.1 17.6 10.7 0.4 0 0.4 0.4 31 5 31 305 28 0 28 0 -16.9 0.1 -16.6 -17.1 03/12/2005 14:40:00 14.8 1.1 17.2 11.8 14.5 1.2 17.6 11.5 0.4 0 0.4 0.4 34 4 33 305 28 0 28 0 -16.9 0.1 -16.4 -16.9 03/12/2005 14:50:00 13.7 1.1 16.8 11.1 13.5 1.1 16.4 11.1 0.4 0 0.4 0.4 35 5 33 305 28 0 28 0 -16.8 0.1 -16.4 -16.9 03/12/2005 15:00:00 13.4 1.1 16.1 10.3 13.1 1.1 16.1 10.3 0.4 0 0.4 0.4 33 5 36 305 28 0 28 0 -16.8 0.1 -16.4 -16.9 03/12/2005 15:10:00 13.1 1.3 16.4 9.9 12.8 1.4 16.8 9.5 0.4 0 0.4 0.4 29 6 29 305 28 0 28 0 -16.9 0.1 -16.4 -17.1 03/12/2005 15:20:00 12.1 1 15.3 9.5 11.9 1.1 15.3 9.5 0.4 0 0.4 0.4 30 5 28 305 28 0 28 0 -16.9 0.1 -16.4 -16.9 03/12/2005 15:30:00 14.2 1.1 16.8 11.5 13.9 1.1 16.8 11.1 0.4 0 0.4 0.4 31 6 32 305 28 0 28 0 -16.9 0.1 -16.4 -17.1 03/12/2005 15:40:00 13.6 1.2 16.4 9.9 13.4 1.2 15.6 10.3 0.4 0 0.4 0.4 34 5 30 305 29 0 29 0 -16.8 0.1 -16.4 -16.9 03/12/2005 15:50:00 12.9 1.1 15.3 9.5 12.6 1.2 15.3 9.1 0.4 0 0.4 0.4 32 6 38 305 29 0 29 0 -16.7 0.2 -16.2 -16.9 03/12/2005 16:00:00 12.7 1.2 16.4 9.9 12.4 1.2 15.3 9.5 0.4 0 0.4 0.4 27 5 29 305 29 0 29 0 -16.7 0.2 -16.2 -16.9 03/12/2005 16:10:00 12.8 1.1 16.1 10.3 12.5 1.1 15.6 10.3 0.4 0 0.4 0.4 28 5 28 305 29 0 29 0 -16.8 0.1 -16.2 -16.9 03/12/2005 16:20:00 12.7 1.1 15.6 9.5 12.4 1.2 15.3 9.1 0.4 0 0.4 0.4 28 6 26 305 29 0 29 0 -16.8 0.1 -16.2 -16.9 03/12/2005 16:30:00 12.1 0.9 14.1 9.9 11.9 1 14.1 9.1 0.4 0 0.4 0.4 27 6 30 305 29 0 29 0 -16.9 0.1 -16.4 -16.9 03/12/2005 16:40:00 14 1.3 16.8 10.3 13.7 1.3 16.8 9.9 0.4 0 0.4 0.4 26 5 25 305 29 0 29 0 -16.9 0 -16.4 -16.9 03/12/2005 16:50:00 14.1 1.2 17.6 10.3 13.8 1.3 16.4 10.3 0.4 0 0.4 0.4 31 5 28 305 29 0 29 0 -16.9 0 -16.4 -16.9 03/12/2005 17:00:00 13.7 1.3 16.4 10.7 13.3 1.4 16.8 10.3 0.4 0 0.4 0.4 31 5 26 305 29 0 29 0 -16.9 0 -16.4 -16.9 03/12/2005 17:10:00 13.4 1.5 16.8 9.9 13 1.4 16.8 10.3 0.4 0 0.4 0.4 30 5 32 305 29 0 29 0 -16.8 0.1 -16.2 -16.9 03/12/2005 17:20:00 14.6 1.2 17.2 11.1 14.2 1.2 17.2 10.3 0.4 0 0.4 0.4 29 5 25 305 29 0 28 0 -16.9 0 -16.4 -16.9 03/12/2005 17:30:00 13.3 0.9 15.6 10.3 12.9 1 15.6 10.3 0.4 0 0.4 0.4 30 5 27 305 28 0 29 0 -16.9 0 -16.2 -16.9 03/12/2005 17:40:00 12.8 1.2 16.4 9.5 12.6 1.2 16.1 9.5 0.4 0 0.4 0.4 32 5 29 305 28 0 28 0 -16.8 0.1 -16.2 -16.9 03/12/2005 17:50:00 13.6 1.1 15.6 9.9 13.3 1.2 16.1 9.5 0.4 0 0.4 0.4 27 4 36 305 28 0 28 0 -16.7 0.2 -16.2 -16.9 03/12/2005 18:00:00 13.2 1 15.3 9.9 13 1 15.6 10.7 0.4 0 0.4 0.4 30 5 21 305 28 0 28 0 -16.6 0.1 -16 -16.9 03/12/2005 18:10:00 12.7 1.2 16.4 9.1 12.4 1.3 15.6 9.5 0.4 0 0.4 0.4 29 6 24 305 28 0 28 0 -16.5 0.1 -16 -16.9 03/12/2005 18:20:00 13.6 1.3 16.4 10.7 13.5 1.4 16.8 9.9 0.4 0 0.4 0.4 25 4 27 305 28 0 28 0 -16.8 0.1 -16.2 -16.9 03/12/2005 18:30:00 12.3 1 14.5 9.1 12.1 1 14.5 9.1 0.4 0 0.4 0.4 26 5 30 305 28 0 28 0 -16.7 0.1 -16.2 -16.9 03/12/2005 18:40:00 12.3 1.1 15.3 9.1 12.1 1.2 15.3 9.1 0.4 0 0.4 0.4 27 5 22 305 27 0 27 0 -16.7 0.1 -16.2 -16.9 03/12/2005 18:50:00 12.7 1.1 15.3 9.5 12.4 1.1 15.3 9.1 0.4 0 0.4 0.4 30 4 33 305 27 0 27 0 -16.6 0.2 -16 -16.9 03/12/2005 19:00:00 12.2 1.4 15.6 8.8 12 1.3 15.3 8.8 0.4 0 0.4 0.4 31 6 32 305 27 0 27 0 -16.7 0.2 -16.2 -16.9 03/12/2005 19:10:00 12.7 1.5 15.6 9.5 12.4 1.5 15.6 9.1 0.4 0 0.4 0.4 30 6 29 305 27 0 27 0 -16.7 0.2 -16.2 -16.9 03/12/2005 19:20:00 12.6 1 15.3 10.3 12.4 1 14.9 9.9 0.4 0 0.4 0.4 34 5 30 305 27 0 27 0 -16.7 0.2 -16.2 -16.9 03/12/2005 19:30:00 13.1 1.1 15.6 9.9 12.9 1.1 15.3 9.5 0.4 0 0.4 0.4 38 5 39 305 27 0 27 0 -16.6 0.1 -16.2 -16.9 03/12/2005 19:40:00 11.9 1 14.9 9.5 11.7 1.1 14.5 9.1 0.4 0 0.4 0.4 36 5 39 305 27 0 27 0 -16.6 0.1 -16 -16.9 03/12/2005 19:50:00 11.5 1 14.1 9.1 11.3 1 14.1 9.1 0.4 0 0.4 0.4 33 5 38 305 26 0 26 0 -16.5 0.1 -16 -16.7 03/12/2005 20:00:00 13 1.4 16.4 9.9 12.8 1.4 16.1 9.5 0.4 0 0.4 0.4 34 5 38 305 26 0 26 0 -16.4 0.1 -16 -16.7 03/12/2005 20:10:00 13 1.3 16.4 9.9 12.8 1.4 16.8 9.5 0.4 0 0.4 0.4 34 5 36 305 26 0 26 0 -16.3 0.2 -15.8 -16.6 03/12/2005 20:20:00 12.2 1.2 14.9 9.1 12.1 1.3 15.3 9.5 0.4 0 0.4 0.4 34 6 29 305 26 0 26 0 -16.2 0.2 -15.8 -16.6 03/12/2005 20:30:00 12.7 1.3 15.3 9.5 12.5 1.3 15.3 8.8 0.4 0 0.4 0.4 31 7 32 305 26 0 26 0 -16.3 0.1 -15.8 -16.6 03/12/2005 20:40:00 13 1.1 16.1 9.5 12.8 1 15.6 9.5 0.4 0 0.4 0.4 36 5 37 305 26 0 26 0 -16.3 0.2 -15.8 -16.6 03/12/2005 20:50:00 13.2 1.1 15.6 10.3 13 1.2 16.1 10.3 0.4 0 0.4 0.4 32 6 23 305 26 0 26 0 -16.3 0.1 -15.8 -16.6 03/12/2005 21:00:00 11.8 0.8 14.1 9.5 11.7 0.9 14.1 8.8 0.4 0 0.4 0.4 33 5 28 305 26 0 27 0 -16.3 0 -15.8 -16.6 03/12/2005 21:10:00 12.1 1 15.3 9.5 11.9 1.1 15.3 9.5 0.4 0 0.4 0.4 32 5 19 305 26 0 26 0 -16.3 0.1 -15.8 -16.4 03/12/2005 21:20:00 11.7 1 13.7 8.4 11.4 1 13.7 8.8 0.4 0 0.4 0.4 32 5 27 305 27 0 26 0 -16.1 0.1 -15.6 -16.4 03/12/2005 21:30:00 11.3 1.2 14.9 8.4 11 1.2 15.3 8.4 0.4 0 0.4 0.4 27 6 27 305 27 0 27 0 -15.9 0 -15.4 -16.2 03/12/2005 21:40:00 12.2 1.1 14.5 8.8 11.9 1.2 14.5 8.8 0.4 0 0.4 0.4 30 5 36 305 27 0 27 0 -16 0.1 -15.6 -16.2 03/12/2005 21:50:00 11.6 1.4 15.3 9.1 11.4 1.4 15.6 8.8 0.4 0 0.4 0.4 29 5 25 305 27 0 27 0 -16 0.1 -15.6 -16.2 03/12/2005 22:00:00 11.6 1.2 14.9 8 11.4 1.3 14.5 8.4 0.4 0 0.4 0.4 27 6 25 305 27 0 27 0 -16 0 -15.6 -16.2 03/12/2005 22:10:00 11.8 1.1 14.9 8.8 11.4 1 14.1 8.8 0.4 0 0.4 0.4 27 5 19 305 27 0 27 0 -16 0 -15.4 -16.2 03/12/2005 22:20:00 11 1.2 13.3 7.6 10.8 1.3 13.3 7.2 0.4 0 0.4 0.4 27 5 32 305 27 0 27 0 -15.9 0 -15.4 -16 03/12/2005 22:30:00 9.8 1 13 7.6 9.6 1 13.3 7.6 0.4 0 0.4 0.4 29 4 28 305 27 0 27 0 -15.8 0 -15.2 -16 03/12/2005 22:40:00 9.2 0.8 11.1 7.2 9 0.8 11.1 6.5 0.4 0 0.4 0.4 27 6 35 305 27 0 27 0 -15.8 0 -15.2 -16 03/12/2005 22:50:00 9.2 0.9 11.5 7.2 9.1 0.9 11.5 7.2 0.4 0 0.4 0.4 29 5 23 305 28 0 28 0 -15.8 0 -15.2 -16 03/12/2005 23:00:00 9.7 1.3 14.5 7.2 9.5 1.3 13.7 6.8 0.4 0 0.4 0.4 30 6 27 305 28 0 28 0 -15.8 0.1 -15.2 -16 03/12/2005 23:10:00 11.7 1.8 15.6 8 11.5 1.8 16.1 8.4 0.4 0 0.4 0.4 29 6 22 305 28 0 28 0 -15.7 0.1 -15.2 -15.8 03/12/2005 23:20:00 11.7 1.5 16.4 8.4 11.5 1.6 16.1 8.8 0.4 0 0.4 0.4 23 5 23 305 28 0 28 0 -15.7 0.1 -15.2 -15.8 03/12/2005 23:30:00 10.6 1.2 13.3 7.6 10.5 1.1 13.3 8 0.4 0 0.4 0.4 25 5 25 305 28 0 28 0 -15.7 0.1 -15.2 -15.8 03/12/2005 23:40:00 10.5 1.1 13 7.2 10.3 1.2 13.3 7.6 0.4 0 0.4 0.4 27 6 27 305 28 0 28 0 -15.7 0.1 -15 -15.8 03/12/2005 23:50:00 10.1 1.1 13.3 8 9.9 1 12.6 7.2 0.4 0 0.4 0.4 29 5 45 305 28 0 28 0 -15.5 0.2 -15 -15.8 03/13/2005 00:00:00 10.6 1.4 13.7 8 10.5 1.4 13.7 7.2 0.4 0 0.4 0.4 23 6 24 305 28 0 28 0 -15.2 0.2 -14.6 -15.6 03/13/2005 00:10:00 11.3 1 14.1 8.8 11.2 1 13.3 8.8 0.4 0 0.4 0.4 23 5 23 305 29 0 28 0 -15.1 0.1 -14.6 -15.4 03/13/2005 00:20:00 11.4 1.3 14.9 7.6 11.2 1.3 14.9 8.8 0.4 0 0.4 0.4 29 6 24 305 29 0 29 0 -15.1 0.2 -14.6 -15.4 03/13/2005 00:30:00 11.5 1.2 13.7 8.8 11.2 1.2 13.7 8 0.4 0 0.4 0.4 33 5 35 305 29 0 29 0 -15.2 0.2 -14.6 -15.6 03/13/2005 00:40:00 11.8 1 14.1 8.8 11.5 1 14.1 9.1 0.4 0 0.4 0.4 35 5 30 305 29 0 29 0 -15.1 0.1 -14.6 -15.2 03/13/2005 00:50:00 11.5 1 14.5 9.5 11.4 1 13.7 8.8 0.4 0 0.4 0.4 34 5 33 305 30 0 29 0 -15 0.2 -14.6 -15.2 03/13/2005 01:00:00 10.3 1 13 8 10.1 1 13.3 8 0.4 0 0.4 0.4 33 6 38 305 30 0 30 0 -14.9 0.1 -14.4 -15 03/13/2005 01:10:00 11.4 1.2 14.1 8.8 11.2 1.2 14.5 8.8 0.4 0 0.4 0.4 29 5 28 305 30 0 30 0 -14.7 0.1 -14.3 -15 03/13/2005 01:20:00 10.7 1 13.3 8.4 10.5 1 13.7 8.8 0.4 0 0.4 0.4 29 5 27 305 31 0 30 0 -14.6 0.1 -14.3 -14.8 03/13/2005 01:30:00 11.8 0.9 14.5 9.5 11.7 0.9 14.1 9.1 0.4 0 0.4 0.4 31 4 27 305 31 0 31 0 -14.7 0 -14.3 -14.8 03/13/2005 01:40:00 10.7 0.9 13 8.8 10.4 1 12.6 7.6 0.4 0 0.4 0.4 29 5 32 305 31 0 31 0 -14.7 0 -14.3 -14.8 03/13/2005 01:50:00 10.8 1 13.3 8.4 10.5 1 13 8 0.4 0 0.4 0.4 33 4 33 305 32 0 32 0 -14.7 0 -14.1 -14.6 03/13/2005 02:00:00 11.2 0.9 13.3 9.1 11.1 1 13.7 8.8 0.4 0 0.4 0.4 30 5 31 305 32 0 32 0 -14.6 0.1 -14.1 -14.6 03/13/2005 02:10:00 11.3 1 13.7 8.4 11.1 1 13.3 8 0.4 0 0.4 0.4 29 5 30 305 32 0 32 0 -14.6 0.1 -14.1 -14.6 03/13/2005 02:20:00 10.9 0.9 13.3 8.8 10.7 1 13.3 8.4 0.4 0 0.4 0.4 29 5 30 305 32 0 32 0 -14.6 0.1 -14.1 -14.6 03/13/2005 02:30:00 10.5 0.9 12.6 8.4 10.4 0.9 12.6 8 0.4 0 0.4 0.4 27 6 32 305 32 0 32 0 -14.6 0 -14.3 -14.6 03/13/2005 02:40:00 11 0.9 13.3 8.8 10.9 1 13.7 8.8 0.4 0 0.4 0.4 23 5 23 305 32 0 32 0 -14.7 0 -14.3 -14.8 03/13/2005 02:50:00 11.7 0.9 14.1 8.8 11.5 1 13.3 9.1 0.4 0 0.4 0.4 26 5 28 305 32 0 32 0 -14.7 0 -14.3 -14.8 03/13/2005 03:00:00 11.2 1.1 13.3 8 11 1.2 13.3 8 0.4 0 0.4 0.4 23 5 23 305 32 0 32 0 -14.7 0 -14.3 -14.8 03/13/2005 03:10:00 10.7 1.3 13.3 8 10.5 1.3 13.7 8 0.4 0 0.4 0.4 24 5 23 305 32 0 32 0 -14.7 0 -14.4 -14.8 03/13/2005 03:20:00 9.1 0.9 11.5 6.8 8.9 0.9 11.5 6.8 0.4 0 0.4 0.4 25 5 23 305 32 0 32 0 -14.7 0 -14.3 -14.8 03/13/2005 03:30:00 9.5 0.9 11.8 7.2 9.4 0.9 11.5 7.2 0.4 0 0.4 0.4 21 5 23 305 32 0 33 0 -14.6 0.1 -14.3 -14.6 03/13/2005 03:40:00 8.9 1 11.1 6.1 8.8 1 11.5 6.5 0.4 0 0.4 0.4 22 5 23 305 33 0 33 0 -14.6 0.1 -14.1 -14.6 03/13/2005 03:50:00 10.2 1.3 13 7.2 10 1.3 12.6 6.8 0.4 0 0.4 0.4 20 6 21 305 33 0 33 0 -14.4 0.2 -13.9 -14.6 03/13/2005 04:00:00 10.2 0.9 12.2 8 10.1 0.9 12.2 8 0.4 0 0.4 0.4 21 5 25 305 33 0 33 0 -14.4 0.2 -13.9 -14.6 03/13/2005 04:10:00 10.3 0.9 11.8 8 10.1 0.9 12.2 7.6 0.4 0 0.4 0.4 19 4 23 305 33 0 33 0 -14.5 0.2 -14.1 -14.6 03/13/2005 04:20:00 9.7 0.9 11.8 7.2 9.4 0.9 11.5 7.2 0.4 0 0.4 0.4 19 4 18 305 33 0 33 0 -14.6 0.1 -14.1 -14.6 03/13/2005 04:30:00 9.5 1 11.1 6.8 9.4 0.9 11.1 6.8 0.4 0 0.4 0.4 18 4 17 305 33 0 33 0 -14.4 0.2 -14.1 -14.6 03/13/2005 04:40:00 8.8 0.8 10.7 6.5 8.7 0.8 11.1 6.1 0.4 0 0.4 0.4 15 5 11 305 33 0 33 0 -14.4 0.2 -13.9 -14.6 03/13/2005 04:50:00 9.1 0.7 10.7 6.8 8.9 0.7 10.3 6.5 0.4 0 0.4 0.4 20 5 18 305 33 0 33 0 -14.4 0.2 -13.9 -14.6 03/13/2005 05:00:00 7.3 0.7 9.1 5.3 7.2 0.7 9.1 5.7 0.4 0 0.4 0.4 14 6 18 305 33 0 33 0 -14.4 0.2 -13.9 -14.6 03/13/2005 05:10:00 7.2 0.7 8.8 4.9 7.2 0.6 8.8 4.9 0.4 0 0.4 0.4 8 4 7 305 33 0 33 0 -14.4 0.2 -13.9 -14.6 03/13/2005 05:20:00 6.8 0.7 8.8 4.6 6.8 0.7 8.4 4.9 0.4 0 0.4 0.4 8 5 8 305 33 0 33 0 -14.4 0.2 -13.9 -14.6 03/13/2005 05:30:00 7.5 0.8 9.1 4.6 7.5 0.8 8.8 4.9 0.4 0 0.4 0.4 5 4 4 305 33 0 33 0 -14.4 0.2 -13.9 -14.6 03/13/2005 05:40:00 7.5 0.8 9.1 4.9 7.5 0.8 9.1 5.3 0.4 0 0.4 0.4 10 6 17 305 33 0 33 0 -14.5 0.2 -13.9 -14.6 03/13/2005 05:50:00 7.3 0.7 8.8 5.7 7.2 0.7 8.8 5.3 0.4 0 0.4 0.4 11 6 9 305 33 0 33 0 -14.5 0.2 -14.1 -14.6 03/13/2005 06:00:00 7.5 0.7 9.1 5.3 7.4 0.7 9.1 5.3 0.4 0 0.4 0.4 12 5 17 305 33 0 33 0 -14.5 0.1 -13.9 -14.6 03/13/2005 06:10:00 7.4 0.7 9.1 5.7 7.3 0.7 9.1 5.3 0.4 0 0.4 0.4 16 5 12 305 33 0 33 0 -14.6 0.1 -14.1 -14.6 03/13/2005 06:20:00 7.6 0.7 8.8 5.3 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 15 4 19 305 33 0 33 0 -14.6 0.1 -14.1 -14.6 03/13/2005 06:30:00 7 0.8 8.8 5.3 6.8 0.8 8.4 4.9 0.4 0 0.4 0.4 18 5 12 305 33 0 33 0 -14.5 0 -14.3 -14.6 03/13/2005 06:40:00 7 0.7 8.4 4.9 6.7 0.8 8.4 4.9 0.4 0 0.4 0.4 22 6 12 305 33 0 33 0 -14.5 0.1 -14.3 -14.6 03/13/2005 06:50:00 6.9 0.7 8.4 4.9 6.7 0.7 8 4.6 0.4 0 0.4 0.4 18 4 14 305 33 0 33 0 -14.5 0.1 -14.3 -14.6 03/13/2005 07:00:00 6.8 0.6 8 4.9 6.7 0.6 8 5.3 0.4 0 0.4 0.4 15 5 19 305 33 0 33 0 -14.6 0.1 -14.1 -14.6 03/13/2005 07:10:00 6.7 0.6 8 5.3 6.5 0.6 7.6 4.9 0.4 0 0.4 0.4 20 4 25 305 33 0 33 0 -14.6 0.1 -14.3 -14.6 03/13/2005 07:20:00 6.6 0.4 7.6 5.3 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 24 3 28 305 33 0 33 0 -14.5 0 -14.3 -14.6 03/13/2005 07:30:00 5.9 0.6 7.2 4.6 5.8 0.5 7.2 4.6 0.4 0 0.4 0.4 21 4 21 305 33 0 33 0 -14.5 0 -14.3 -14.6 03/13/2005 07:40:00 5.9 0.5 6.8 4.2 5.7 0.5 6.5 4.2 0.4 0 0.4 0.4 24 5 22 305 33 0 33 0 -14.5 0.1 -13.9 -14.6 03/13/2005 07:50:00 6.2 0.4 7.2 4.6 6 0.5 7.2 4.6 0.4 0 0.4 0.4 25 4 31 305 33 0 34 0 -14.6 0.1 -14.3 -14.6 03/13/2005 08:00:00 5.7 0.5 6.8 3.8 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 25 6 22 305 33 0 33 0 -14.5 0.1 -14.1 -14.6 03/13/2005 08:10:00 6 0.5 7.2 4.6 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 33 5 38 305 34 0 34 0 -14.6 0.1 -14.1 -14.6 03/13/2005 08:20:00 5.7 0.7 7.2 4.2 5.6 0.7 7.2 3.8 0.4 0 0.4 0.4 30 4 27 305 34 0 34 0 -14.5 0.2 -14.1 -14.6 03/13/2005 08:30:00 5.1 0.6 6.5 3.4 5 0.6 6.5 3.4 0.4 0 0.4 0.4 29 5 26 305 34 0 34 0 -14.4 0.2 -13.9 -14.6 03/13/2005 08:40:00 5.4 0.6 6.5 3.4 5.3 0.6 6.5 3.4 0.4 0 0.4 0.4 36 4 36 305 34 0 34 0 -14.4 0.2 -13.9 -14.6 03/13/2005 08:50:00 5.2 0.5 6.5 4.2 5 0.5 6.1 3.8 0.4 0 0.4 0.4 34 5 35 305 34 0 34 0 -14.4 0.2 -13.9 -14.6 03/13/2005 09:00:00 6 0.5 7.2 4.6 5.8 0.5 7.2 4.6 0.4 0 0.4 0.4 32 4 35 305 34 0 34 0 -14.4 0.2 -13.9 -14.6 03/13/2005 09:10:00 5.6 0.5 6.8 4.2 5.3 0.5 6.5 3.8 0.4 0 0.4 0.4 33 5 31 305 34 0 34 0 -14.3 0.2 -13.9 -14.6 03/13/2005 09:20:00 5.7 0.4 6.5 4.6 5.5 0.4 6.5 4.2 0.4 0 0.4 0.4 34 4 35 305 34 0 34 0 -14.4 0.2 -13.9 -14.6 03/13/2005 09:30:00 5.1 0.5 6.5 3.8 5 0.5 6.1 3.8 0.4 0 0.4 0.4 32 4 36 305 34 0 34 0 -14.3 0.1 -13.9 -14.6 03/13/2005 09:40:00 4.9 0.6 6.1 3.4 4.8 0.6 5.7 3 0.4 0 0.4 0.4 34 5 33 305 35 0 34 0 -14.3 0.2 -13.9 -14.6 03/13/2005 09:50:00 4.4 0.4 5.3 3 4.3 0.4 5.3 3 0.4 0 0.4 0.4 34 6 30 305 35 0 35 0 -14.3 0.1 -13.7 -14.4 03/13/2005 10:00:00 3.7 0.5 4.6 1.9 3.5 0.5 4.6 2.3 0.4 0 0.4 0.4 33 5 36 305 35 0 35 0 -14.2 0.1 -13.7 -14.4 03/13/2005 10:10:00 3.1 0.3 3.8 2.3 2.9 0.4 3.8 1.9 0.4 0 0.4 0.4 28 8 32 305 36 0 35 0 -14.1 0.1 -13.7 -14.3 03/13/2005 10:20:00 2.7 0.4 3.4 1.9 2.6 0.4 3.4 1.9 0.4 0 0.4 0.4 32 5 33 305 36 0 36 0 -14.1 0.2 -13.7 -14.3 03/13/2005 10:30:00 2.9 0.3 3.4 1.9 2.8 0.3 3.4 1.5 0.4 0 0.4 0.4 47 6 52 305 37 0 36 0 -14 0.2 -13.5 -14.3 03/13/2005 10:40:00 2.8 0.4 3.8 1.9 2.7 0.4 3.4 1.9 0.4 0 0.4 0.4 40 6 39 305 38 0 38 0 -14.1 0.1 -13.7 -14.3 03/13/2005 10:50:00 2.4 0.4 3 1.5 2.2 0.4 3 1.5 0.4 0 0.4 0.4 46 10 42 305 39 0 38 0 -14 0 -13.3 -14.3 03/13/2005 11:00:00 3.2 0.4 3.8 1.9 3 0.4 3.8 1.9 0.4 0 0.4 0.4 60 6 62 305 40 0 40 0 -13.7 0 -13.3 -13.9 03/13/2005 11:10:00 3.3 0.4 4.2 2.6 3.3 0.4 4.2 2.3 0.4 0 0.4 0.4 56 4 51 305 40 0 40 0 -13.8 0 -13.5 -14.1 03/13/2005 11:20:00 3.2 0.3 3.8 2.3 3 0.3 3.8 1.5 0.4 0 0.4 0.4 56 6 50 305 41 0 41 0 -13.8 0 -13.5 -14.1 03/13/2005 11:30:00 2.9 0.3 3.8 1.9 2.8 0.4 3.8 1.9 0.4 0 0.4 0.4 53 9 47 305 42 0 41 0 -13.7 0 -13.3 -13.7 03/13/2005 11:40:00 2.8 0.4 3.8 1.9 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 53 6 56 305 42 0 42 0 -13.7 0 -13.3 -13.7 03/13/2005 11:50:00 3.6 0.5 4.9 2.6 3.5 0.6 4.9 2.3 0.4 0 0.4 0.4 56 7 58 305 44 0 44 0 -13.6 0 -13.3 -13.7 03/13/2005 12:00:00 4.6 0.4 5.3 3.4 4.4 0.4 5.3 3 0.4 0 0.4 0.4 56 5 59 305 44 0 44 0 -13.6 0 -13.1 -13.7 03/13/2005 12:10:00 5.1 0.3 5.7 4.2 4.9 0.4 5.7 3.8 0.4 0 0.4 0.4 51 3 53 305 45 0 45 0 -13.7 0 -13.3 -13.7 03/13/2005 12:20:00 5 0.4 6.1 3.8 4.8 0.5 5.7 3.8 0.4 0 0.4 0.4 49 5 53 305 46 0 46 0 -13.7 0 -13.3 -13.7 03/13/2005 12:30:00 5.3 0.4 6.1 4.2 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 50 5 60 305 47 0 47 0 -13.6 0 -13.3 -13.7 03/13/2005 12:40:00 5.3 0.7 6.8 3.4 5.1 0.9 6.8 3.4 0.4 0 0.4 0.4 52 5 49 305 48 0 48 0 -13.6 0 -13.1 -13.7 03/13/2005 12:50:00 6.5 0.5 7.2 4.9 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 60 4 59 305 48 0 48 0 -13.6 0.1 -13.1 -13.7 03/13/2005 13:00:00 6.6 0.5 8 4.9 6.5 0.6 8 5.3 0.4 0 0.4 0.4 65 4 66 305 46 1 47 0 -13.4 0.2 -12.9 -13.7 03/13/2005 13:10:00 6.6 0.8 8.4 4.2 6.4 0.8 8 3.4 0.4 0 0.4 0.4 61 6 69 305 45 0 45 0 -13.3 0.2 -12.9 -13.7 03/13/2005 13:20:00 6.1 1.3 9.5 3.4 5.9 1.4 9.5 3 0.4 0 0.4 0.4 58 8 62 305 45 0 45 0 -13.3 0.2 -12.9 -13.7 03/13/2005 13:30:00 4.3 0.8 6.1 1.9 4.2 0.7 6.1 2.3 0.4 0 0.4 0.4 47 16 54 305 47 0 47 0 -13.2 0.2 -12.7 -13.5 03/13/2005 13:40:00 4.4 0.8 7.2 2.3 4.3 0.8 6.8 2.3 0.4 0 0.4 0.4 35 12 32 305 48 1 49 0 -13.2 0.1 -12.7 -13.3 03/13/2005 13:50:00 5.1 0.8 7.2 3.4 5.2 0.8 7.2 3.4 0.4 0 0.4 0.4 40 11 46 305 50 0 50 0 -13.2 0.1 -12.7 -13.3 03/13/2005 14:00:00 6.5 1.2 8.8 3.8 6.1 1.1 8.4 3.4 0.4 0 0.4 0.4 59 13 72 305 52 0 52 0 -13.1 0.1 -12.7 -13.3 03/13/2005 14:10:00 8.1 0.7 9.9 6.1 7.5 0.7 9.5 5.7 0.4 0 0.4 0.4 78 9 87 305 51 1 53 0 -13 0.2 -12.5 -13.3 03/13/2005 14:20:00 8.8 0.7 10.3 6.5 7.9 0.7 9.5 5.7 0.4 0 0.4 0.4 88 6 99 305 48 1 46 0 -12.8 0.1 -12.3 -13.1 03/13/2005 14:30:00 9.8 0.5 11.1 8.4 9 0.5 10.3 7.6 0.4 0 0.4 0.4 97 3 98 305 45 0 44 0 -12.9 0.2 -12.5 -13.1 03/13/2005 14:40:00 10.6 0.5 11.8 8.8 9.8 0.5 10.7 8.4 0.4 0 0.4 0.4 102 2 102 305 43 0 43 0 -12.9 0.2 -12.5 -13.1 03/13/2005 14:50:00 10.6 0.4 11.5 9.5 9.8 0.4 10.7 8.8 0.4 0 0.4 0.4 103 3 102 305 43 0 43 0 -12.9 0.1 -12.5 -13.1 03/13/2005 15:00:00 10 0.7 12.2 8 9.4 0.6 11.5 7.6 0.4 0 0.4 0.4 101 5 93 305 42 0 42 0 -12.9 0.1 -12.5 -13.1 03/13/2005 15:10:00 9 1.1 11.5 5.7 8.6 0.9 11.1 5.7 0.4 0 0.4 0.4 94 8 97 305 42 0 42 0 -12.9 0.1 -12.5 -13.1 03/13/2005 15:20:00 7 1.3 11.1 4.2 6.7 1.3 10.3 3.8 0.4 0 0.4 0.4 82 15 87 305 42 0 42 0 -12.8 0 -12.5 -12.9 03/13/2005 15:30:00 5.7 1.1 9.9 3.4 5.5 1.1 10.3 3.4 0.4 0 0.4 0.4 64 16 84 305 44 0 43 0 -12.9 0.1 -12.5 -13.1 03/13/2005 15:40:00 5.2 1.1 8.4 2.6 5 1 7.6 2.6 0.4 0 0.4 0.4 52 19 77 305 46 1 46 0 -13 0 -12.7 -13.1 03/13/2005 15:50:00 4.4 1.2 7.6 1.9 4.3 1 7.6 1.9 0.4 0 0.4 0.4 51 22 75 305 49 1 48 0 -12.9 0 -12.7 -13.1 03/13/2005 16:00:00 4.9 0.8 7.6 2.3 5 0.9 7.2 1.9 0.4 0 0.4 0.4 30 19 19 305 51 1 50 0 -12.9 0.1 -12.5 -13.1 03/13/2005 16:10:00 4.1 1.2 7.6 1.1 3.6 1.1 6.8 1.1 0.4 0 0.4 0.4 65 33 81 305 53 0 53 0 -12.8 0 -12.5 -12.9 03/13/2005 16:20:00 7.2 1.1 10.3 3.4 6.8 1.1 9.5 3.4 0.4 0 0.4 0.4 104 9 113 305 54 1 52 0 -12.4 0.1 -12.1 -12.7 03/13/2005 16:30:00 9.4 0.7 11.5 7.2 9.1 0.7 11.1 6.8 0.4 0 0.4 0.4 115 5 119 305 49 1 48 0 -12.5 0 -12.3 -12.5 03/13/2005 16:40:00 9.8 0.8 12.2 7.6 9.3 0.8 11.5 6.8 0.4 0 0.4 0.4 115 5 117 305 46 0 46 0 -12.4 0.1 -12.1 -12.5 03/13/2005 16:50:00 9 0.8 10.7 6.5 8.7 0.7 10.3 6.5 0.4 0 0.4 0.4 114 5 113 305 47 0 46 0 -11.6 0.2 -10.9 -12.1 03/13/2005 17:00:00 9.3 0.7 11.5 6.8 8.9 0.7 11.1 6.5 0.4 0 0.4 0.4 115 6 109 305 48 0 48 0 -11.8 0.3 -11.3 -12.5 03/13/2005 17:10:00 10.3 0.8 13 8.4 10 0.7 11.8 8.4 0.4 0 0.4 0.4 120 5 116 305 46 0 46 0 -12.3 0.1 -11.7 -12.5 03/13/2005 17:20:00 11.6 0.7 13.3 9.5 11.1 0.7 13 9.1 0.4 0 0.4 0.4 117 4 123 305 46 0 46 0 -12.5 0.1 -12.1 -12.5 03/13/2005 17:30:00 11.5 0.6 13 9.5 11 0.6 13 9.1 0.4 0 0.4 0.4 118 5 124 305 45 0 45 0 -12.4 0.1 -12.1 -12.5 03/13/2005 17:40:00 11.4 0.6 13 9.5 11 0.7 12.6 9.1 0.4 0 0.4 0.4 117 5 119 305 45 0 45 0 -12.4 0.2 -11.9 -12.5 03/13/2005 17:50:00 11.1 0.6 13 9.5 10.7 0.6 12.2 8.8 0.4 0 0.4 0.4 118 5 118 305 45 0 45 0 -12.2 0.1 -11.7 -12.5 03/13/2005 18:00:00 11 0.6 12.6 9.5 10.7 0.5 11.8 9.5 0.4 0 0.4 0.4 117 4 111 305 46 0 46 0 -12.2 0.1 -11.7 -12.5 03/13/2005 18:10:00 10.6 0.5 12.2 9.1 10.4 0.5 11.8 8.8 0.4 0 0.4 0.4 120 4 123 305 46 0 46 0 -12 0.1 -11.7 -12.3 03/13/2005 18:20:00 11 0.6 12.6 9.1 10.6 0.6 12.2 9.1 0.4 0 0.4 0.4 112 6 106 305 46 0 46 0 -12.1 0.1 -11.7 -12.5 03/13/2005 18:30:00 11.4 0.7 13 9.5 10.8 0.7 13 8.8 0.4 0 0.4 0.4 111 5 112 305 46 0 46 0 -12.1 0.1 -11.7 -12.5 03/13/2005 18:40:00 11.5 0.7 13 9.5 10.9 0.6 13 9.5 0.4 0 0.4 0.4 111 5 107 305 46 0 46 0 -12 0.1 -11.5 -12.3 03/13/2005 18:50:00 11.3 0.6 13 9.5 10.8 0.6 12.2 9.1 0.4 0 0.4 0.4 108 5 119 305 47 0 47 0 -12.1 0.1 -11.7 -12.5 03/13/2005 19:00:00 11.7 0.5 13 10.7 10.9 0.5 12.2 9.1 0.4 0 0.4 0.4 105 4 105 305 47 0 47 0 -12.1 0.1 -11.7 -12.5 03/13/2005 19:10:00 11.7 0.5 13 10.3 11.1 0.5 12.2 9.9 0.4 0 0.4 0.4 107 3 108 305 47 0 47 0 -12 0.1 -11.7 -12.3 03/13/2005 19:20:00 12 0.5 13.3 10.3 11.3 0.5 12.6 9.5 0.4 0 0.4 0.4 107 3 105 305 47 0 47 0 -11.9 0.2 -11.5 -12.3 03/13/2005 19:30:00 12 0.4 13.3 11.1 11.3 0.4 12.6 10.3 0.4 0 0.4 0.4 106 2 103 305 48 0 49 0 -11.8 0.1 -11.3 -12.1 03/13/2005 19:40:00 11.7 0.5 13 9.9 11 0.5 12.2 9.5 0.4 0 0.4 0.4 105 3 108 305 49 0 49 0 -11.6 0.1 -11.3 -12.1 03/13/2005 19:50:00 11.8 0.5 13 9.1 11.1 0.4 12.6 9.9 0.4 0 0.4 0.4 106 3 110 305 51 0 52 0 -11.3 0.2 -10.7 -11.7 03/13/2005 20:00:00 12 0.7 14.9 9.1 11.2 0.7 13.3 8.8 0.4 0 0.4 0.4 105 5 107 305 53 0 53 0 -11.1 0.1 -10.4 -11.3 03/13/2005 20:10:00 10.1 1.1 13 7.2 9.5 1.1 12.6 6.5 0.4 0 0.4 0.4 100 8 106 305 54 1 54 0 -10.9 0.2 -10.4 -11.3 03/13/2005 20:20:00 10.1 1.5 13.7 6.1 9.6 1.5 13.3 6.1 0.4 0 0.4 0.4 96 13 109 305 56 1 57 0 -10.4 0.2 -9.8 -10.9 03/13/2005 20:30:00 11.3 1.6 15.3 7.2 10.6 1.4 14.5 7.2 0.4 0 0.4 0.4 98 9 106 305 59 1 59 0 -9.9 0.2 -9.2 -10.4 03/13/2005 20:40:00 12.4 1.3 15.3 8.8 11.8 1.4 15.3 8.8 0.4 0 0.4 0.4 98 10 99 305 62 0 62 0 -9.8 0.2 -9 -10.4 03/13/2005 20:50:00 12 1.5 15.3 8 11.3 1.3 14.1 8 0.4 0 0.4 0.4 98 9 93 305 61 0 61 0 -10.2 0.1 -9.6 -10.4 03/13/2005 21:00:00 12.1 1.6 17.2 7.6 11.5 1.5 15.6 7.2 0.4 0 0.4 0.4 100 12 102 305 62 0 61 0 -9.9 0.1 -9.6 -10.2 03/13/2005 21:10:00 11.3 1.7 17.2 7.6 10.7 1.7 15.6 6.8 0.4 0 0.4 0.4 97 11 94 305 63 0 64 0 -9.5 0.2 -9 -10 03/13/2005 21:20:00 9.8 1.6 14.1 5.3 9.4 1.6 14.1 5.7 0.4 0 0.4 0.4 101 13 118 305 66 1 66 0 -9.1 0.1 -8.8 -9.4 03/13/2005 21:30:00 9.6 1.7 14.9 5.3 9.2 1.5 13 4.6 0.4 0 0.4 0.4 93 14 108 305 68 1 68 0 -8.7 0.3 -8.2 -9.2 03/13/2005 21:40:00 10 1.6 13.7 5.7 9.5 1.5 14.1 5.7 0.4 0 0.4 0.4 86 13 80 305 71 1 73 0 -7.9 0.2 -7.3 -8.4 03/13/2005 21:50:00 10.4 1.3 14.9 6.8 10.1 1.3 14.5 6.8 0.4 0 0.4 0.4 83 9 86 305 73 0 73 0 -7.9 0.2 -7.3 -8.4 03/13/2005 22:00:00 10.6 1.7 16.4 6.5 10.2 1.7 15.3 7.2 0.4 0 0.4 0.4 84 12 83 305 75 1 74 0 -7.4 0.2 -6.7 -7.7 03/13/2005 22:10:00 9.6 1.8 14.5 4.6 9.3 1.7 13.7 4.6 0.4 0 0.4 0.4 90 17 71 305 78 1 77 0 -6.9 0.1 -6.4 -7.1 03/13/2005 22:20:00 10.1 2.2 15.6 4.6 9.8 2.2 16.1 4.9 0.4 0 0.4 0.4 83 15 94 305 80 0 80 0 -7 0.2 -6.4 -7.5 03/13/2005 22:30:00 9.4 1.8 13.7 3 9.1 1.8 14.1 4.6 0.4 0 0.4 0.4 85 16 57 305 80 0 80 0 -7.4 0.1 -6.9 -7.7 03/13/2005 22:40:00 8.9 1.7 13.3 4.2 8.7 1.7 13.3 4.2 0.4 0 0.4 0.4 72 13 59 305 79 0 79 0 -7.6 0.1 -7.1 -7.7 03/13/2005 22:50:00 7.5 1.5 11.5 3.8 7.3 1.6 11.5 3.4 0.4 0 0.4 0.4 74 15 71 305 79 0 79 0 -7.6 0.1 -7.1 -7.7 03/13/2005 23:00:00 6.7 1.4 11.5 3.4 6.4 1.3 11.1 2.6 0.4 0 0.4 0.4 72 15 63 305 80 0 80 0 -7.3 0 -6.9 -7.7 03/13/2005 23:10:00 5.5 1.3 8.8 2.3 5.1 1.4 9.1 2.6 0.4 0 0.4 0.4 87 21 89 305 81 0 82 0 -6.8 0.2 -6.2 -7.3 03/13/2005 23:20:00 5 1.4 8.4 2.3 4.5 1.5 8 1.5 0.4 0 0.4 0.4 86 18 103 305 83 0 82 0 -6.5 0.1 -6 -6.9 03/13/2005 23:30:00 3.3 1 7.2 0.4 2.7 1.2 5.7 0.4 0.4 0 0.4 0.4 83 30 109 305 85 0 85 0 -5.9 0.1 -5.6 -6.2 03/13/2005 23:40:00 4.5 1 7.2 2.3 4.3 1.1 7.6 1.9 0.4 0 0.4 0.4 73 15 76 305 86 0 87 0 -6 0.1 -5.6 -6.2 03/13/2005 23:50:00 7.6 1.7 13.7 4.2 7.1 1.6 13 3.8 0.4 0 0.4 0.4 91 18 95 305 89 1 91 0 -4.7 0.5 -3.8 -5.6 03/14/2005 00:00:00 8.4 2 14.1 4.2 7.8 1.8 13.7 3.4 0.4 0 0.4 0.4 98 20 96 305 92 1 89 0 -3.7 0.1 -3.3 -3.8 03/14/2005 00:10:00 7.2 1.6 12.6 3.4 6.9 1.7 13 3 0.4 0 0.4 0.4 92 20 70 305 93 0 93 0 -3.7 0 -3.3 -3.8 03/14/2005 00:20:00 6.5 1.5 9.9 1.9 6.3 1.5 10.3 2.3 0.4 0 0.4 0.4 74 17 72 305 93 0 93 0 -3.9 0.2 -3.3 -4.2 03/14/2005 00:30:00 7.1 1.6 11.5 2.6 6.7 1.5 10.3 3 0.4 0 0.4 0.4 77 20 96 305 94 0 94 0 -4.2 0 -4 -4.5 03/14/2005 00:40:00 7.4 1.7 12.2 3.4 7.4 1.8 12.2 3 0.4 0 0.4 0.4 69 17 69 305 93 0 93 0 -3.9 0 -3.8 -4 03/14/2005 00:50:00 7.3 2.1 12.6 1.9 6.9 2.1 11.8 1.9 0.4 0 0.4 0.4 80 21 43 305 94 0 94 0 -3.7 0.1 -3.1 -4 03/14/2005 01:00:00 6.7 1.6 12.2 3 6.2 1.7 11.5 2.6 0.4 0 0.4 0.4 87 17 90 305 95 0 95 0 -3.1 0.2 -2.7 -3.6 03/14/2005 01:10:00 6.3 1.6 11.5 3 6.1 1.7 11.1 2.3 0.4 0 0.4 0.4 98 21 120 305 96 0 96 0 -2.7 0 -2.4 -2.9 03/14/2005 01:20:00 6 1.8 11.1 1.9 5.6 1.7 11.5 1.9 0.4 0 0.4 0.4 103 19 91 305 97 0 96 0 -2.6 0 -2.4 -2.7 03/14/2005 01:30:00 6.9 1.9 12.2 3.4 6.5 1.9 11.8 3 0.4 0 0.4 0.4 111 20 101 305 98 0 97 0 -2.6 0 -2.4 -2.7 03/14/2005 01:40:00 12.4 3.3 18.3 2.6 11.9 3.2 17.6 3.4 0.4 0 0.4 0.4 136 8 136 305 99 1 99 0 -1.6 0.5 -1.1 -2.4 03/14/2005 01:50:00 13.7 1.3 16.4 9.9 13.3 1.3 16.4 9.5 0.4 0 0.4 0.4 132 6 136 305 101 0 101 0 -1.2 0 -1.1 -1.5 03/14/2005 02:00:00 10.5 1.8 14.5 4.9 10.3 1.8 14.9 4.6 0.4 0 0.4 0.4 129 13 128 305 102 0 102 0 -1.5 0 -0.8 -1.8 03/14/2005 02:10:00 10.2 2 15.3 6.1 9.9 2 15.3 5.7 0.4 0 0.4 0.4 121 15 122 305 103 0 103 0 -1.5 0 -1.3 -1.8 03/14/2005 02:20:00 9.6 1.9 14.5 5.3 9.1 1.9 14.5 4.6 0.4 0 0.4 0.4 126 17 115 305 103 0 103 0 -1.5 0 -1.3 -1.8 03/14/2005 02:30:00 10.4 2.1 15.6 6.1 10.3 2 16.4 5.7 0.4 0 0.4 0.4 131 16 123 305 104 0 104 0 -1.5 0 -1.3 -1.5 03/14/2005 02:40:00 10.9 1.9 15.6 5.3 10.6 2.1 16.4 4.9 0.4 0 0.4 0.4 130 15 135 305 104 0 104 0 -1.3 0 -1.1 -1.3 03/14/2005 02:50:00 10 2.3 16.8 5.7 9.5 2.3 16.4 4.9 0.4 0 0.4 0.4 128 15 123 305 104 0 104 0 -1.2 0 -1.1 -1.3 03/14/2005 03:00:00 10.2 2 16.1 5.7 9.8 1.8 15.6 5.3 0.4 0 0.4 0.4 126 15 116 305 105 0 105 0 -1.2 0 -1.1 -1.3 03/14/2005 03:10:00 11 2 15.3 4.9 10.7 1.9 14.9 4.9 0.4 0 0.4 0.4 130 15 141 305 105 0 105 0 -1.2 0 -1.1 -1.3 03/14/2005 03:20:00 12.9 2.3 19.1 7.2 12.6 2.3 18.3 6.5 0.4 0 0.4 0.4 132 12 138 305 106 0 106 0 -1.1 0 -0.8 -1.3 03/14/2005 03:30:00 13.7 2.1 19.1 8.4 13.4 2 19.9 8.4 0.4 0 0.4 0.4 133 11 127 305 106 0 106 0 -0.9 0 -0.6 -1.1 03/14/2005 03:40:00 15 1.7 19.1 10.7 14.6 1.6 18.3 10.7 0.4 0 0.4 0.4 133 8 137 305 106 0 106 0 -0.8 0 -0.6 -1.1 03/14/2005 03:50:00 15 1.7 20.6 9.9 14.6 1.7 20.2 10.7 0.4 0 0.4 0.4 134 7 151 305 106 0 107 0 -0.7 0 -0.4 -0.8 03/14/2005 04:00:00 15 1.7 20.6 9.5 14.5 1.7 20.2 9.5 0.4 0 0.4 0.4 134 8 146 305 107 1 107 0 -0.7 0 0.1 -0.8 03/14/2005 04:10:00 15.3 1.7 19.5 10.7 14.9 1.6 19.5 10.7 0.4 0 0.4 0.4 135 7 129 305 111 1 110 0 -0.6 0.1 0.1 -0.6 03/14/2005 04:20:00 15.1 2.2 21 9.9 14.6 2.3 21 8.8 0.4 0.1 0.7 0.4 135 9 136 305 113 0 113 0 -0.5 0.1 0.1 -0.6 03/14/2005 04:30:00 15.7 2 20.2 10.3 15.2 2 20.2 9.9 0.4 0.1 0.7 0.4 134 9 124 305 114 1 113 0 -0.4 0.1 0.1 -0.4 03/14/2005 04:40:00 16 1.7 20.2 10.7 15.6 1.6 19.1 10.7 0.4 0.1 0.7 0.4 134 8 106 305 115 0 116 0 -0.3 0.1 0.1 -0.4 03/14/2005 04:50:00 15.8 1.6 19.5 11.5 15.4 1.5 19.1 11.1 0.4 0.1 0.7 0.4 134 6 124 305 116 0 116 0 -0.4 0.1 0.1 -0.6 03/14/2005 05:00:00 16.4 2 21.4 12.2 15.9 1.8 20.6 11.5 0.4 0.1 1.1 0.4 133 8 135 305 116 0 116 0 -0.4 0.1 0.1 -0.6 03/14/2005 05:10:00 16.1 1.7 19.9 11.5 15.6 1.5 19.1 10.3 0.8 1 8.4 0.4 133 7 146 305 116 1 117 0 -0.4 0 0.1 -0.6 03/14/2005 05:20:00 16 1.9 21.4 10.7 15.5 2 21.4 11.1 0.4 0 0.4 0.4 134 8 138 305 114 1 113 0 -0.5 0 0.1 -0.6 03/14/2005 05:30:00 15.8 2.1 21.4 10.7 15.2 2 20.6 9.5 0.4 0 0.4 0.4 134 8 132 305 114 0 114 0 -0.5 0 0.1 -0.6 03/14/2005 05:40:00 16.6 2.2 20.6 10.7 16 2.1 20.2 9.9 0.4 0 0.4 0.4 134 7 137 305 112 1 112 0 -0.4 0.1 0.1 -0.6 03/14/2005 05:50:00 16.8 1.7 20.6 12.2 16.2 1.7 21 12.2 0.4 0 0.4 0.4 135 7 143 305 112 1 112 0 -0.3 0 0.1 -0.4 03/14/2005 06:00:00 16.2 1.9 21.4 10.7 16 2 21.4 10.3 0.4 0 0.4 0.4 136 8 142 305 112 1 113 0 -0.3 0 0.1 -0.4 03/14/2005 06:10:00 15.6 2.2 22.1 10.3 15.3 2.1 20.2 10.3 0.4 0 0.4 0.4 137 10 140 305 112 1 114 0 -0.3 0 0.1 -0.4 03/14/2005 06:20:00 14.4 2.3 21.4 9.5 14.2 2.2 20.6 9.1 0.4 0 0.4 0.4 141 11 138 305 113 1 113 0 -0.4 0 0.1 -0.4 03/14/2005 06:30:00 15.5 2.4 20.6 9.1 15.2 2.2 20.2 9.5 0.4 0 0.4 0.4 137 9 133 305 114 1 114 0 -0.4 0.1 0.1 -0.6 03/14/2005 06:40:00 15.7 2.1 21 10.7 15.6 2.1 21 11.1 0.4 0 0.4 0.4 136 9 131 305 116 0 116 0 -0.5 0 -0.1 -0.6 03/14/2005 06:50:00 17 1.9 21.4 10.3 16.6 1.9 21 10.3 0.4 0 0.4 0.4 134 7 129 305 116 0 116 0 -0.6 0 -0.1 -0.6 03/14/2005 07:00:00 17.1 2.1 23.7 12.6 16.7 2.1 22.6 9.9 0.4 0 0.4 0.4 134 7 141 305 116 1 116 0 -0.6 0 -0.4 -0.6 03/14/2005 07:10:00 17.1 1.6 21 11.8 16.6 1.6 20.2 12.2 0.4 0 0.4 0.4 133 7 139 305 116 0 116 0 -0.7 0 -0.6 -0.8 03/14/2005 07:20:00 15.9 1.6 19.9 11.8 15.5 1.5 19.5 11.5 0.4 0 0.4 0.4 134 7 131 305 116 0 116 0 -0.7 0 -0.6 -0.8 03/14/2005 07:30:00 16 1.7 20.6 10.7 15.5 1.8 19.5 10.3 0.4 0 0.4 0.4 133 7 125 305 116 1 115 0 -0.7 0 -0.6 -0.8 03/14/2005 07:40:00 15.3 1.7 21 11.1 14.9 1.7 19.5 10.7 0.4 0 0.4 0.4 134 7 130 305 117 1 117 0 -0.7 0 -0.6 -0.8 03/14/2005 07:50:00 16.5 2 21.4 9.5 15.8 2.1 20.6 8.8 0.4 0 0.4 0.4 134 8 127 305 115 0 114 0 -0.6 0 -0.1 -0.6 03/14/2005 08:00:00 16.5 1.9 20.6 11.5 16.1 1.9 21 11.8 0.4 0 0.4 0.4 134 7 131 305 115 1 113 0 -0.5 0.1 0.1 -0.6 03/14/2005 08:10:00 16.3 1.9 21 11.1 16 1.8 20.2 10.7 0.4 0 0.4 0.4 134 8 127 305 113 1 113 0 -0.4 0.1 0.1 -0.6 03/14/2005 08:20:00 15.9 2.5 21.8 9.9 15.5 2.4 21.4 10.3 0.4 0 0.4 0.4 134 8 138 305 111 0 111 0 -0.4 0.1 0.1 -0.6 03/14/2005 08:30:00 15.9 2.1 20.2 9.1 15.5 1.9 19.9 10.3 0.4 0 0.4 0.4 136 8 140 305 112 0 112 0 -0.4 0.1 0.1 -0.6 03/14/2005 08:40:00 15.3 2.2 21.8 8.8 14.9 2.2 21.4 9.1 0.4 0 0.4 0.4 137 9 140 305 113 0 113 0 -0.3 0 0.1 -0.4 03/14/2005 08:50:00 15.5 2.5 22.6 8 15.3 2.4 22.1 9.5 0.4 0 0.4 0.4 136 9 120 305 112 0 112 0 -0.3 0 0.1 -0.4 03/14/2005 09:00:00 16.4 2.2 21.8 9.5 16.1 2 21.8 10.7 0.4 0 0.4 0.4 135 8 135 305 112 0 112 0 -0.3 0 -0.1 -0.4 03/14/2005 09:10:00 16.9 1.9 21.4 11.5 16.5 1.8 20.6 11.5 0.4 0 0.4 0.4 134 8 136 305 112 0 112 0 -0.3 0 -0.1 -0.4 03/14/2005 09:20:00 16.4 2.4 21.8 9.5 16.2 2.1 21.4 9.9 0.4 0 0.4 0.4 134 9 140 305 112 0 112 0 -0.2 0 0.3 -0.4 03/14/2005 09:30:00 17.8 1.6 21.4 13.3 17.2 1.6 21 13.3 0.4 0 0.4 0.4 133 6 139 305 110 1 109 0 -0.1 0 0.3 -0.4 03/14/2005 09:40:00 18.6 1.5 22.9 13.3 18 1.6 22.6 13.7 0.4 0 0.4 0.4 135 6 138 305 109 0 109 0 -0.1 0 0.3 -0.1 03/14/2005 09:50:00 18.1 1.8 23.7 13.7 17.7 1.9 24.4 13 0.4 0 0.4 0.4 135 8 136 305 109 0 109 0 0 0 0.3 -0.1 03/14/2005 10:00:00 16.5 2.3 21.4 10.3 16.2 2.3 21.8 9.5 0.4 0 0.4 0.4 137 9 137 305 109 0 109 0 0 0 0.6 -0.1 03/14/2005 10:10:00 15.7 2.1 21.4 11.1 15.3 2.1 21 11.1 0.4 0 0.4 0.4 139 10 124 305 108 0 108 0 0 0 0.3 -0.1 03/14/2005 10:20:00 15.7 2 21.8 11.1 15.3 1.9 20.6 10.7 0.4 0 0.4 0.4 140 9 145 305 109 1 108 0 0 0 0.6 -0.1 03/14/2005 10:30:00 16 2 21.8 11.1 15.5 2.1 22.1 10.7 0.4 0 0.4 0.4 139 10 137 305 108 0 108 0 0 0 0.6 -0.1 03/14/2005 10:40:00 15 2.2 20.2 9.5 14.5 2.1 21.8 9.5 0.4 0 0.4 0.4 141 10 140 305 109 1 108 0 0 0 0.3 -0.1 03/14/2005 10:50:00 14.9 2.1 21 9.9 14.5 2 19.9 9.9 0.4 0 0.4 0.4 141 10 130 305 110 0 111 0 0 0 0.3 -0.1 03/14/2005 11:00:00 14.8 2 19.5 9.1 14.4 1.8 19.1 9.5 0.4 0 0.4 0.4 143 10 151 305 110 1 111 0 0 0 0.6 0.1 03/14/2005 11:10:00 15.2 2 20.2 9.9 14.7 1.9 19.1 10.3 0.4 0 0.4 0.4 145 9 150 305 111 0 111 0 0 0 0.3 0.1 03/14/2005 11:20:00 15.9 1.7 20.2 11.5 15.2 1.7 19.1 11.1 0.4 0 0.4 0.4 145 8 152 305 111 0 112 0 0 0 0.6 0.1 03/14/2005 11:30:00 15.1 1.8 19.1 8.8 14.5 1.8 19.9 10.3 0.4 0 0.4 0.4 146 8 150 305 110 1 110 0 0 0 0.6 0.1 03/14/2005 11:40:00 14.7 2.3 19.1 6.8 14.4 1.7 18.7 9.9 0.4 0 0.4 0.4 148 10 152 305 111 1 110 0 0 0 0.6 0.1 03/14/2005 11:50:00 14.2 2.6 20.2 8 14.2 2.2 19.1 9.5 0.4 0 0.4 0.4 150 10 145 305 111 1 111 0 0 0 0.6 0.1 03/14/2005 12:00:00 13.7 2.3 19.1 6.8 13.6 2.1 19.1 8.4 0.4 0.2 2.6 0.4 149 9 144 305 111 1 111 0 0.1 0 0.6 0.1 03/14/2005 12:10:00 13.9 2.2 19.9 7.6 14.1 1.8 19.5 8 8.9 6.4 17.9 0.4 150 11 152 305 110 0 110 0 0.1 0 0.6 0.1 03/14/2005 12:20:00 13.6 2.5 19.9 7.6 13.7 2 19.5 8.4 10.9 3.1 17.6 0.4 150 10 162 305 109 0 109 0 0.1 0 0.6 0.1 03/14/2005 12:30:00 13.8 2.5 20.2 8 13.9 2 19.1 8.8 5.8 3.3 14.9 0.4 152 9 141 305 109 0 109 0 0.2 0 0.6 0.1 03/14/2005 12:40:00 13.1 2.1 18.7 6.5 13 1.7 17.9 8.8 4.6 2.9 13 0.4 150 9 140 305 109 0 108 0 0.4 0 0.8 0.3 03/14/2005 12:50:00 13 2.3 18.3 7.6 13.2 1.8 18.3 8.4 10.4 3.6 16.8 0.4 151 10 143 305 108 0 108 0 0.4 0 0.8 0.3 03/14/2005 13:00:00 12.6 1.9 17.2 7.2 12.8 1.8 18.7 8.4 12.8 1.8 18.7 8.4 153 10 144 305 108 1 109 0 0.4 0 0.8 0.3 03/14/2005 13:10:00 12.1 2.1 16.4 6.1 12.6 1.7 16.1 8 12.6 1.7 16.1 8 153 11 151 305 107 0 107 0 0.4 0 0.8 0.3 03/14/2005 13:20:00 11.9 1.8 16.4 7.2 12.5 1.6 16.8 8.4 12.5 1.6 16.8 8 154 11 150 305 106 1 106 0 0.4 0 1 0.3 03/14/2005 13:30:00 11.4 1.9 18.3 6.8 12.4 1.7 17.2 8.8 12.4 1.7 17.2 8.8 157 9 148 305 142 13 109 0 0.4 0 0.8 0.3 03/14/2005 13:40:00 10.9 1.9 16.8 6.5 12.4 1.5 19.5 8 12.4 1.5 19.5 8 161 9 152 305 154 1 154 0 0.4 0 0.8 0.3 03/14/2005 13:50:00 10.9 1.9 16.1 6.5 12.1 1.7 17.9 8 12.1 1.7 17.9 8 160 9 156 305 154 0 154 0 0.4 0 0.8 0.3 03/14/2005 14:00:00 11 1.8 16.1 6.1 12.2 1.5 17.2 8.4 12.2 1.5 17.2 8 160 8 152 305 153 0 153 0 0.3 0 0.8 0.3 03/14/2005 14:10:00 10.4 1.6 15.3 7.2 11.9 1.2 14.5 8.8 11.9 1.2 14.5 8.8 159 8 147 305 153 0 152 0 0.3 0 0.8 0.3 03/14/2005 14:20:00 10.8 1.7 15.6 6.8 11.6 1.3 16.4 8.4 11.6 1.4 16.4 8.4 158 7 154 305 152 0 152 0 0.3 0 0.8 0.3 03/14/2005 14:30:00 10.2 1.6 14.9 6.5 11.2 1.3 14.9 8.4 11.2 1.3 14.9 8 158 7 158 305 151 0 151 0 0.3 0 0.8 0.3 03/14/2005 14:40:00 9.9 1.7 14.5 6.1 10.8 1.3 15.6 7.6 10.8 1.4 15.3 6.8 157 8 153 305 149 0 149 0 0.3 0 0.6 0.3 03/14/2005 14:50:00 10 1.6 14.1 5.7 10.6 1.1 13.3 6.8 10.4 1.3 13.3 5.7 156 7 152 305 148 0 148 0 0.3 0 0.6 0.3 03/14/2005 15:00:00 10.1 1.7 13.7 5.7 10.6 1.1 14.1 7.6 10.2 1.4 13.7 6.5 156 7 164 305 147 0 147 0 0.3 0 0.6 0.1 03/14/2005 15:10:00 9.5 1.7 13.7 5.7 10.4 1.1 13.7 7.6 6.9 4 13.7 0.4 157 7 150 305 145 1 145 0 0.3 0 0.6 0.1 03/14/2005 15:20:00 9.6 1.5 14.1 5.7 10.7 1.1 14.5 7.6 3.7 3.5 13.3 0.4 159 6 152 305 145 0 145 0 0.3 0 0.6 0.1 03/14/2005 15:30:00 9 1.5 13.7 5.7 10.4 1.1 14.1 8 8.4 3.2 12.6 0.4 160 5 150 305 147 2 147 0 0.3 0 0.6 0.1 03/14/2005 15:40:00 8.9 1.5 12.6 6.1 10.6 0.8 12.6 8.4 10.4 1 12.6 7.6 160 4 152 305 146 1 147 0 0.3 0 0.6 0.1 03/14/2005 15:50:00 8.4 1.5 11.8 5.3 10.3 0.9 12.6 7.6 10.3 1 12.6 7.6 161 4 152 305 144 0 144 0 0.3 0 0.6 0.1 03/14/2005 16:00:00 8.4 1.3 12.2 5.7 10.3 0.7 11.8 8 10.1 0.9 11.8 7.2 161 4 152 305 145 0 145 0 0.2 0 0.6 0.1 03/14/2005 16:10:00 7.9 1.2 12.6 4.9 10 0.7 11.5 7.6 8.2 1.8 10.7 0.4 162 4 156 305 148 3 145 0 0.2 0.1 0.6 0.1 03/14/2005 16:20:00 7.1 1.1 10.7 4.6 9.4 0.7 11.1 7.2 1 1.7 8.4 0.4 163 3 155 305 149 0 148 0 0.1 0.1 0.6 0.1 03/14/2005 16:30:00 6.6 0.9 10.3 4.6 9 0.6 10.7 7.2 0.4 0 0.4 0.4 163 3 161 305 149 0 148 0 0.1 0.1 0.6 0.1 03/14/2005 16:40:00 6.4 1 9.5 4.2 8.7 0.6 10.3 7.2 0.4 0.1 1.9 0.4 163 3 154 305 150 1 149 0 0.1 0.1 0.6 0.1 03/14/2005 16:50:00 6.1 1 9.9 4.2 8.2 0.7 9.9 6.5 5.9 2 8.4 0.4 163 3 159 305 151 0 151 0 0.2 0.1 0.6 0.1 03/14/2005 17:00:00 6.2 1 9.1 3.8 7.7 0.6 9.1 5.7 6.8 0.7 8.4 4.6 162 4 155 305 149 1 150 0 0.1 0.1 0.6 0.1 03/14/2005 17:10:00 6.4 1 9.5 3.4 7.3 0.6 8.8 5.3 6.5 0.6 8 4.2 159 4 157 305 147 2 146 0 0.1 0.1 0.6 0.1 03/14/2005 17:20:00 6.1 1.1 9.1 3.8 6.8 0.6 8.4 4.9 6.5 0.6 8 4.6 159 4 160 305 155 1 156 0 0 0 0.6 0.1 03/14/2005 17:30:00 5.8 1 8.4 3 6.5 0.6 8 4.9 6.1 0.6 8 4.2 160 4 151 305 152 1 154 0 0 0 0.6 0.1 03/14/2005 17:40:00 4.9 0.9 7.2 3 6.2 0.5 7.2 4.9 5.7 0.6 7.2 3 162 4 158 305 150 0 151 0 0 0 0.6 -0.1 03/14/2005 17:50:00 4.5 0.7 7.2 3 6.4 0.6 8 4.9 4.6 1.5 6.8 0.4 165 4 155 305 149 0 149 0 0 0 0.3 -0.1 03/14/2005 18:00:00 4.3 0.7 6.8 2.6 5.9 0.6 7.6 4.6 0.4 0.5 4.6 0.4 164 4 166 305 150 0 149 0 -0.1 0 0.3 -0.1 03/14/2005 18:10:00 4.7 0.8 6.8 3 6.1 0.5 7.6 4.6 0.8 1 5.3 0.4 162 4 156 305 148 1 148 0 -0.1 0 0.3 -0.4 03/14/2005 18:20:00 5.4 0.9 7.6 3.4 6 0.4 7.2 4.9 0.8 0.8 4.2 0.4 158 3 158 305 148 1 150 0 -0.2 0 0.3 -0.4 03/14/2005 18:30:00 5.5 0.9 7.6 3.4 6.2 0.4 7.2 5.3 0.4 0.5 5.3 0.4 158 3 161 305 150 0 150 0 -0.2 0 0.3 -0.4 03/14/2005 18:40:00 6.3 0.9 8 3.8 6.5 0.4 7.6 5.3 4.6 2.7 7.6 0.4 157 3 155 305 150 0 150 0 -0.3 0 0.3 -0.4 03/14/2005 18:50:00 7.2 0.8 8.8 3.8 6.8 0.5 8 5.3 6.2 1.1 7.6 1.9 154 2 154 305 149 1 150 0 -0.3 0 0.3 -0.4 03/14/2005 19:00:00 7.5 0.7 8.8 4.9 6.9 0.5 8 5.3 6.2 0.5 7.2 3.8 154 1 154 305 147 0 148 0 -0.3 0 0.1 -0.4 03/14/2005 19:10:00 7.4 0.8 8.8 4.6 6.9 0.4 7.6 6.1 5.7 0.7 6.8 1.9 154 0 154 305 146 0 147 0 -0.3 0.1 0.1 -0.4 03/14/2005 19:20:00 7.5 0.6 8.8 4.9 7 0.4 8.4 5.7 1.9 2.4 6.8 0.4 154 0 154 305 148 1 148 0 -0.4 0.1 0.1 -0.4 03/14/2005 19:30:00 7.4 0.6 8.8 4.6 6.9 0.5 8.4 5.7 5 1.4 7.6 0.4 154 0 154 305 148 0 147 0 -0.4 0.1 0.1 -0.6 03/14/2005 19:40:00 7.2 0.7 8.4 4.6 6.7 0.5 8 5.3 2.9 2.5 7.6 0.7 154 0 154 305 146 0 146 0 -0.4 0.1 0.1 -0.6 03/14/2005 19:50:00 7.1 0.7 8.8 4.6 6.7 0.5 8 5.3 1.3 1.4 7.2 0.7 154 0 154 305 145 0 145 0 -0.5 0.1 0.1 -0.6 03/14/2005 20:00:00 6.9 0.8 8.4 4.2 6.4 0.5 8 5.3 0.8 0.2 1.1 0.4 154 0 154 305 144 0 144 0 -0.5 0 0.1 -0.6 03/14/2005 20:10:00 6.3 0.9 8.4 3.8 6.4 0.5 7.6 4.9 0.6 0.2 1.1 0.4 154 0 154 305 143 0 144 0 -0.6 0 0.1 -0.6 03/14/2005 20:20:00 6 0.9 8.4 3.4 6.1 0.4 7.2 4.9 0.6 0.2 0.7 0.4 154 0 154 305 143 0 143 0 -0.6 0 0.1 -0.6 03/14/2005 20:30:00 6.3 0.8 8.4 4.2 6.1 0.5 7.6 4.9 0.6 0.2 1.1 0.4 154 0 154 305 142 0 142 0 -0.6 0 -0.1 -0.6 03/14/2005 20:40:00 6.9 0.8 8.4 4.6 6.5 0.5 7.6 4.9 0.7 0.1 1.1 0.4 154 0 154 305 142 0 142 0 -0.6 0 -0.1 -0.6 03/14/2005 20:50:00 6.5 0.9 8.4 4.6 6.3 0.6 7.6 4.2 0.7 0.2 1.1 0.4 154 0 154 305 141 0 142 0 -0.6 0 -0.1 -0.6 03/14/2005 21:00:00 5.5 1.1 7.6 2.6 5.7 0.5 6.8 4.2 0.7 0.2 1.1 0.4 154 0 154 305 140 0 141 0 -0.7 0 -0.1 -0.8 03/14/2005 21:10:00 4.6 0.9 6.8 2.6 5.3 0.5 6.5 4.2 0.5 0.2 0.7 0.4 154 0 154 305 139 0 139 0 -0.7 0 -0.4 -0.8 03/14/2005 21:20:00 5 1 7.2 2.6 5.7 0.5 6.8 4.6 0.6 0.2 0.7 0.4 154 0 154 305 139 0 139 0 -0.7 0 -0.1 -0.8 03/14/2005 21:30:00 5.3 0.8 7.2 3.4 5.9 0.5 6.8 4.9 0.7 0.2 1.1 0.4 154 0 154 305 138 0 138 0 -0.7 0 -0.1 -0.6 03/14/2005 21:40:00 4.7 0.8 6.5 2.6 5.7 0.4 6.5 4.6 0.7 0.1 1.1 0.4 154 0 154 305 138 0 138 0 -0.7 0 -0.1 -0.8 03/14/2005 21:50:00 4.1 0.6 5.7 2.6 5.5 0.4 6.5 4.6 1.1 1.3 6.5 0.4 154 0 155 305 137 0 137 0 -0.7 0 -0.4 -0.8 03/14/2005 22:00:00 3.9 0.6 5.7 2.6 5.2 0.4 6.1 4.2 0.7 0.1 1.1 0.4 154 0 155 305 137 0 137 0 -0.7 0 -0.4 -0.8 03/14/2005 22:10:00 3.2 0.5 4.9 2.3 4.5 0.4 5.3 3.4 0.8 0.2 1.1 0.4 154 0 155 305 136 0 136 0 -0.8 0 -0.4 -1.1 03/14/2005 22:20:00 2.7 0.4 3.8 1.5 4.4 0.6 5.3 3 0.9 0.2 1.5 0.4 155 0 155 305 135 0 136 0 -0.7 0 -0.4 -0.8 03/14/2005 22:30:00 3.4 0.6 4.6 1.9 3.9 0.4 4.9 2.6 1.6 1.3 4.9 0.7 155 0 155 305 135 0 135 0 -0.8 0 -0.4 -0.8 03/14/2005 22:40:00 3.7 0.5 4.6 2.6 4.2 0.3 4.9 3.4 4 0.6 4.9 1.1 155 0 155 305 134 0 135 0 -0.7 0 -0.4 -0.8 03/14/2005 22:50:00 3.7 0.4 4.9 2.6 3.9 0.4 4.9 3 2.5 1.2 4.6 0.7 155 0 155 305 132 1 132 0 -0.8 0 -0.4 -1.1 03/14/2005 23:00:00 3.2 0.3 3.8 2.3 2.9 0.3 3.8 1.9 1.4 0.8 3.4 0.4 155 0 156 305 130 0 131 0 -0.9 0.1 -0.4 -1.1 03/14/2005 23:10:00 2.7 0.3 3.4 1.9 2.5 0.3 3.4 1.9 1.1 0.6 3 0.7 155 0 156 305 130 0 130 0 -0.9 0.1 -0.4 -1.1 03/14/2005 23:20:00 2.7 0.4 3.4 1.9 2.4 0.4 3.4 1.5 1.3 0.7 3.4 0.4 155 0 156 305 129 0 129 0 -0.8 0.1 -0.4 -1.1 03/14/2005 23:30:00 3 0.4 3.8 2.3 2.8 0.4 3.8 1.9 1.6 0.8 3.4 0.7 156 0 156 305 129 0 129 0 -0.8 0 -0.4 -1.1 03/14/2005 23:40:00 3.1 0.3 4.2 2.3 2.9 0.3 3.8 1.9 1.2 0.8 3.4 0.4 156 0 156 305 128 0 128 0 -1 0.1 -0.4 -1.1 03/14/2005 23:50:00 2.7 0.4 3.8 1.9 2.5 0.4 3.8 1.5 0.7 0.1 1.1 0.4 156 0 156 305 128 0 129 0 -1 0.1 -0.4 -1.1 03/15/2005 00:00:00 2.7 0.4 3.4 1.5 2.4 0.4 3.4 1.5 0.6 0.2 0.7 0.4 156 0 156 305 128 0 128 0 -1.1 0.1 -0.6 -1.1 03/15/2005 00:10:00 2.8 0.4 3.4 1.9 2.5 0.3 3.4 1.5 0.7 0.1 0.7 0.4 156 0 156 305 127 0 127 0 -1.1 0 -0.6 -1.1 03/15/2005 00:20:00 2.3 0.3 3 1.5 2.1 0.3 3 1.5 0.7 0.1 0.7 0.4 156 0 156 305 126 0 127 0 -1.1 0 -0.6 -1.3 03/15/2005 00:30:00 2.8 0.3 3.4 1.9 2.6 0.3 3.4 1.5 0.7 0.1 1.1 0.4 156 0 156 305 126 0 126 0 -1.1 0 -0.6 -1.3 03/15/2005 00:40:00 2.7 0.3 3.4 2.3 2.5 0.3 3 1.9 0.8 0.2 3 0.4 156 0 156 305 125 0 125 0 -1.2 0 -0.6 -1.3 03/15/2005 00:50:00 2.5 0.3 3.4 1.9 2.4 0.2 3 1.9 0.9 0.4 2.6 0.4 156 0 156 305 124 0 124 0 -1.3 0 -0.6 -1.3 03/15/2005 01:00:00 2.6 0.3 3.4 1.9 2.2 0.3 3 1.5 1.3 0.7 2.6 0.4 156 0 156 305 123 0 124 0 -1.3 0 -0.8 -1.3 03/15/2005 01:10:00 2.3 0.3 3 1.5 2.1 0.3 3 1.1 0.4 0.2 1.9 0.4 156 0 156 305 122 0 122 0 -1.4 0 -0.8 -1.3 03/15/2005 01:20:00 1.6 0.3 2.6 0.4 1.4 0.4 2.3 0.4 0.4 0 0.4 0.4 156 0 156 305 124 1 121 0 -1.4 0 -0.8 -1.5 03/15/2005 01:30:00 1.8 0.3 2.3 1.1 1.5 0.3 2.3 0.7 0.4 0 0.4 0.4 156 0 156 305 124 0 125 0 -1.3 0 -0.8 -1.3 03/15/2005 01:40:00 1.9 0.2 2.6 1.5 1.6 0.2 2.3 0.7 0.4 0 0.4 0.4 156 0 156 305 123 0 124 0 -1.4 0 -1.1 -1.5 03/15/2005 01:50:00 2 0.2 2.6 1.5 1.8 0.2 2.3 1.1 0.8 0.5 2.3 0.4 156 0 156 305 123 0 123 0 -1.5 0.1 -1.1 -1.8 03/15/2005 02:00:00 2.1 0.3 3 1.5 1.9 0.2 2.6 1.1 0.8 0.5 2.3 0.4 156 0 156 305 123 0 122 0 -1.5 0.1 -1.1 -1.8 03/15/2005 02:10:00 2.1 0.3 2.6 1.5 1.9 0.3 2.6 1.1 0.6 0.2 0.7 0.4 156 0 156 305 123 0 123 0 -1.6 0.1 -1.1 -1.8 03/15/2005 02:20:00 2.1 0.2 2.6 1.5 2 0.3 2.6 1.1 0.6 0.2 0.7 0.4 156 0 156 305 122 0 122 0 -1.6 0 -1.1 -1.8 03/15/2005 02:30:00 2.4 0.3 3 1.9 2.2 0.3 2.6 1.5 0.4 0.2 0.7 0.4 156 0 156 305 122 0 122 0 -1.7 0 -1.1 -1.8 03/15/2005 02:40:00 2.4 0.3 3 1.5 2.2 0.3 2.6 1.1 0.4 0 0.4 0.4 156 0 156 305 121 0 121 0 -1.6 0 -1.1 -1.8 03/15/2005 02:50:00 2.3 0.3 3 1.5 2.1 0.3 3 1.5 0.4 0 0.4 0.4 156 0 156 305 120 0 120 0 -1.6 0.1 -1.1 -1.8 03/15/2005 03:00:00 2.5 0.3 3 1.5 2.3 0.2 3 1.9 0.4 0 0.4 0.4 156 0 156 305 119 0 119 0 -1.6 0.1 -1.1 -1.8 03/15/2005 03:10:00 2.1 0.3 3 1.5 1.9 0.3 2.6 1.1 0.4 0 0.4 0.4 156 0 156 305 119 0 119 0 -1.6 0.1 -1.1 -1.8 03/15/2005 03:20:00 2.8 0.3 3.8 2.3 2.4 0.3 3.4 1.5 0.4 0 0.4 0.4 156 0 156 305 119 0 119 0 -1.6 0.2 -1.1 -1.8 03/15/2005 03:30:00 3 0.2 3.4 2.6 2.9 0.3 3.4 2.3 0.4 0 0.4 0.4 156 0 156 305 119 0 119 0 -1.5 0.1 -1.1 -1.8 03/15/2005 03:40:00 3 0.3 3.8 2.3 2.8 0.3 3.4 1.9 0.4 0 0.4 0.4 156 0 156 305 119 0 118 0 -1.7 0 -1.1 -1.8 03/15/2005 03:50:00 3.6 0.3 4.2 2.6 3.5 0.3 4.2 3 0.4 0 0.4 0.4 156 0 156 305 118 0 117 0 -1.8 0 -1.3 -2 03/15/2005 04:00:00 3.6 0.3 4.2 2.6 3.5 0.4 4.6 2.6 0.4 0 0.4 0.4 156 0 156 305 117 0 117 0 -1.9 0.1 -1.3 -2 03/15/2005 04:10:00 3.4 0.3 4.2 2.3 3.5 0.4 4.2 2.6 0.4 0 0.4 0.4 157 0 156 305 117 0 117 0 -2.1 0.1 -1.5 -2.2 03/15/2005 04:20:00 3.5 0.4 4.6 2.6 3.6 0.5 4.9 2.6 0.4 0 0.4 0.4 157 0 156 305 116 0 116 0 -2.3 0 -1.8 -2.4 03/15/2005 04:30:00 4.2 0.4 4.9 3 4.5 0.5 5.3 3 0.4 0 0.4 0.4 157 0 156 305 115 0 116 0 -2.4 0 -2 -2.7 03/15/2005 04:40:00 4 0.2 4.6 3.4 4.3 0.2 4.9 3.4 0.4 0 0.4 0.4 157 0 156 305 114 0 114 0 -2.6 0.1 -2 -2.7 03/15/2005 04:50:00 4 0.4 4.9 3.4 4.3 0.4 4.9 3.4 0.4 0 0.4 0.4 157 0 156 305 114 0 114 0 -3 0.1 -2.7 -3.3 03/15/2005 05:00:00 4 0.3 4.6 3.4 4.3 0.3 4.9 3.4 0.4 0 0.4 0.4 157 0 156 305 113 0 113 0 -3.1 0.1 -2.4 -3.3 03/15/2005 05:10:00 3.6 0.3 4.2 3 3.9 0.3 4.6 3.4 0.4 0 0.4 0.4 157 0 157 305 112 0 112 0 -3 0.1 -2.4 -3.1 03/15/2005 05:20:00 3 0.2 3.8 2.6 3.2 0.2 3.8 2.6 0.4 0 0.4 0.4 157 0 156 305 112 0 112 0 -3.1 0.1 -2.7 -3.3 03/15/2005 05:30:00 3.7 0.4 4.6 2.6 3.6 0.4 4.6 2.3 0.4 0 0.4 0.4 157 0 156 305 112 0 112 0 -3 0 -2.4 -3.1 03/15/2005 05:40:00 4 0.3 4.9 3 4 0.4 4.9 3 0.4 0 0.4 0.4 157 0 156 305 112 0 112 0 -2.8 0 -2.4 -2.9 03/15/2005 05:50:00 3.8 0.3 4.6 3 4 0.3 4.9 3 0.4 0 0.4 0.4 157 0 156 305 112 0 112 0 -3.1 0.1 -2.4 -3.3 03/15/2005 06:00:00 3.7 0.2 4.2 3 3.7 0.3 4.6 3 0.4 0 0.4 0.4 157 0 157 305 112 0 112 0 -3.3 0 -3.1 -3.3 03/15/2005 06:10:00 3.9 0.2 4.6 3.4 4.1 0.2 4.9 3.4 0.4 0 0.4 0.4 157 0 157 305 111 0 111 0 -3.6 0.1 -3.1 -3.8 03/15/2005 06:20:00 3.8 0.3 4.2 3 3.8 0.3 4.6 2.6 0.4 0 0.7 0.4 157 0 157 305 111 0 111 0 -3.9 0 -3.8 -4.2 03/15/2005 06:30:00 3.9 0.3 4.6 3 3.8 0.3 4.6 2.6 0.4 0 0.4 0.4 157 0 157 305 110 0 110 0 -4.2 0 -4 -4.5 03/15/2005 06:40:00 4.1 0.3 4.6 3.4 4 0.3 4.6 3 0.5 0.2 1.1 0.4 157 0 157 305 109 0 109 0 -4.3 0 -4 -4.5 03/15/2005 06:50:00 4.4 0.3 4.9 3.4 4.3 0.3 4.9 3.4 0.8 0.3 1.5 0.4 157 0 157 305 108 1 109 0 -4.3 0 -3.8 -4.5 03/15/2005 07:00:00 4.5 0.2 4.9 3.8 4.4 0.3 4.9 3.4 1 0.2 1.9 0.4 157 0 157 305 106 0 106 0 -4.4 0 -4 -4.5 03/15/2005 07:10:00 4.4 0.3 5.3 3.4 4.3 0.5 5.3 2.3 0.9 0.2 1.5 0.4 157 0 157 305 106 0 106 0 -4.4 0 -3.8 -4.5 03/15/2005 07:20:00 4.1 0.3 4.6 3.4 4 0.3 4.9 3.4 0.8 0.2 1.1 0.4 157 0 157 305 105 0 105 0 -4.4 0 -4 -4.7 03/15/2005 07:30:00 4.2 0.2 4.9 3.4 4 0.3 4.9 3.4 0.7 0.2 1.1 0.4 157 0 157 305 105 0 105 0 -4.6 0.1 -4 -4.7 03/15/2005 07:40:00 4.3 0.3 4.9 3.8 4.1 0.3 4.6 3 0.5 0.2 0.7 0.4 157 0 157 305 105 0 105 0 -4.7 0 -4.2 -4.7 03/15/2005 07:50:00 3.9 0.3 4.6 3 3.8 0.3 4.6 3 0.4 0.1 0.7 0.4 157 0 157 305 105 0 105 0 -4.8 0 -4.7 -4.9 03/15/2005 08:00:00 3.8 0.3 4.6 3 3.5 0.4 4.6 2.6 0.4 0 0.4 0.4 157 0 157 305 104 0 105 0 -4.7 0 -4.5 -4.7 03/15/2005 08:10:00 3.6 0.5 4.6 2.3 3.3 0.6 4.6 1.9 0.4 0 0.4 0.4 157 0 157 305 104 0 104 0 -4.7 0 -4.7 -4.9 03/15/2005 08:20:00 3.5 0.4 4.6 2.6 3.2 0.5 4.6 2.3 0.4 0 0.4 0.4 157 0 157 305 104 0 104 0 -4.7 0 -4.5 -4.7 03/15/2005 08:30:00 3 0.3 3.8 2.3 2.6 0.4 3.4 1.9 0.4 0 0.4 0.4 157 0 157 305 105 0 104 0 -4.6 0 -4.5 -4.7 03/15/2005 08:40:00 3.2 0.3 4.2 2.6 2.6 0.4 3.4 1.9 0.4 0 0.4 0.4 157 0 157 305 105 0 105 0 -4.5 0 -4.5 -4.7 03/15/2005 08:50:00 2.7 0.3 3.4 1.9 1.4 0.9 2.6 0.4 0.4 0 0.4 0.4 157 0 157 305 105 0 105 0 -4.6 0 -4.5 -4.7 03/15/2005 09:00:00 2.4 0.4 3.4 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 106 0 0 0 -4.5 0 -4.5 -4.7 03/15/2005 09:10:00 2.5 0.4 3.4 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 106 0 0 0 -4.5 0 -4.5 -4.7 03/15/2005 09:20:00 2.3 0.5 3.4 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 106 0 0 0 -4.5 0 -4.2 -4.7 03/15/2005 09:30:00 2.8 0.3 3.8 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 107 0 0 0 -4.6 0 -4.5 -4.7 03/15/2005 09:40:00 3 0.4 4.2 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 107 0 0 0 -4.7 0 -4.5 -4.7 03/15/2005 09:50:00 3 0.3 3.8 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 107 0 0 0 -4.6 0 -4.5 -4.7 03/15/2005 10:00:00 2.9 0.5 3.8 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 107 0 0 0 -4.6 0 -4.5 -4.7 03/15/2005 10:10:00 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 108 0 0 0 -4.6 0 -4.5 -4.7 03/15/2005 10:20:00 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 107 0 0 0 -4.6 0 -4.5 -4.7 03/15/2005 10:30:00 3.5 0.3 4.2 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 107 0 0 0 -4.4 0 -4 -4.7 03/15/2005 10:40:00 3.7 0.2 4.6 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 108 0 0 0 -4.4 0 -4.2 -4.7 03/15/2005 10:50:00 3.9 0.3 4.9 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 108 0 0 0 -4.5 0 -4 -4.7 03/15/2005 11:00:00 3.7 0.3 4.6 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -4.5 0 -4.5 -4.7 03/15/2005 11:10:00 3.8 0.2 4.6 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -4.5 0 -4.5 -4.7 03/15/2005 11:20:00 3.7 0.3 4.6 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 110 0 0 0 -4.5 0 -4.5 -4.7 03/15/2005 11:30:00 3.9 0.3 4.6 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 110 0 0 0 -4.7 0 -4.5 -4.7 03/15/2005 11:40:00 3.8 0.4 4.6 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 111 0 0 0 -4.5 0 -4.5 -4.7 03/15/2005 11:50:00 3.5 0.4 4.6 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 111 0 0 0 -4.5 0 -4.5 -4.7 03/15/2005 12:00:00 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 112 0 0 0 -4.2 0 -4 -4.5 03/15/2005 12:10:00 4 0.4 4.9 3.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 157 0 157 305 113 0 0 0 -4.1 0.1 -3.8 -4.2 03/15/2005 12:20:00 3.9 0.4 4.9 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 114 0 0 0 -4.2 0 -3.8 -4.5 03/15/2005 12:30:00 4 0.4 4.9 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 114 0 0 0 -4.2 0 -4 -4.5 03/15/2005 12:40:00 3.7 0.3 4.6 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 114 0 0 0 -4 0.1 -3.8 -4 03/15/2005 12:50:00 3.4 0.4 4.9 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 116 1 0 0 -3.1 0.3 -2.7 -3.8 03/15/2005 13:00:00 3 0.4 3.8 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 118 0 0 0 -2.7 0.1 -2.4 -2.9 03/15/2005 13:10:00 2.8 0.3 3.8 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 118 0 0 0 -2.8 0 -2.2 -3.1 03/15/2005 13:20:00 3.2 0.3 3.8 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 118 0 0 0 -3 0 -2.4 -3.1 03/15/2005 13:30:00 3.2 0.3 4.2 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 118 0 0 0 -3 0.1 -2.7 -3.3 03/15/2005 13:40:00 3.5 0.2 4.2 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 118 0 0 0 -3.4 0 -3.3 -3.6 03/15/2005 13:50:00 3.7 0.3 4.2 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 118 0 0 0 -3.7 0.1 -3.3 -3.8 03/15/2005 14:00:00 3.1 0.4 4.2 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 117 0 0 0 -3.7 0 -3.3 -3.8 03/15/2005 14:10:00 2.8 0.2 3.4 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 118 0 0 0 -3.2 0.1 -3.1 -3.6 03/15/2005 14:20:00 3.2 0.3 3.8 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 118 0 0 0 -3 0 -2.4 -3.1 03/15/2005 14:30:00 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 119 0 0 0 -3 0 -2.4 -3.1 03/15/2005 14:40:00 2.6 0.4 3.4 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 119 0 0 0 -2.8 0 -2.2 -3.1 03/15/2005 14:50:00 2.7 0.2 3.4 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 119 0 0 0 -2.6 0 -2 -2.7 03/15/2005 15:00:00 2.3 0.2 3 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 119 0 0 0 -2.4 0 -2 -2.7 03/15/2005 15:10:00 2.2 0.2 2.6 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 119 0 0 0 -2.4 0 -2 -2.4 03/15/2005 15:20:00 2.1 0.3 2.6 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 119 0 0 0 -2.6 0.1 -2 -2.7 03/15/2005 15:30:00 2.2 0.4 3 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 118 0 0 0 -2.6 0.2 -2 -2.7 03/15/2005 15:40:00 1.8 0.4 3 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 118 0 0 0 -2.6 0.2 -2 -2.7 03/15/2005 15:50:00 1.5 0.4 2.6 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 117 0 0 0 -2.6 0.2 -1.8 -2.9 03/15/2005 16:00:00 2.2 0.3 3 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 117 0 0 0 -2.2 0.1 -1.8 -2.4 03/15/2005 16:10:00 2.2 0.4 3 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 117 0 0 0 -2.3 0.1 -1.8 -2.4 03/15/2005 16:20:00 2.2 0.4 3 0.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 116 0 0 0 -2.2 0.1 -1.8 -2.4 03/15/2005 16:30:00 1.6 0.4 2.6 0.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 116 1 0 0 -2.2 0 -1.8 -2.4 03/15/2005 16:40:00 2.7 0.8 3.8 0.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 116 0 0 0 -2.3 0 -1.8 -2.4 03/15/2005 16:50:00 2.9 0.5 4.2 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 116 0 0 0 -2.4 0 -2 -2.4 03/15/2005 17:00:00 2.1 0.5 3.4 0.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 114 0 0 0 -2.4 0 -2 -2.7 03/15/2005 17:10:00 3 0.3 3.4 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 114 0 0 0 -2.3 0 -1.8 -2.4 03/15/2005 17:20:00 1.9 0.7 3.8 0.7 0.4 0 0.4 0.4 0.5 0.2 0.7 0.4 157 0 156 305 113 0 0 0 -2.3 0 -1.8 -2.4 03/15/2005 17:30:00 2.1 0.5 3.4 1.1 0.4 0 0.4 0.4 0.7 0.1 0.7 0.4 157 0 156 305 113 0 0 0 -2.5 0.1 -2 -2.7 03/15/2005 17:40:00 2.4 0.7 3.8 0.7 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 157 0 156 305 112 0 0 0 -2.4 0 -1.8 -2.7 03/15/2005 17:50:00 2 0.7 3.4 0.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 112 0 0 0 -2.4 0.1 -1.8 -2.7 03/15/2005 18:00:00 2.2 0.8 4.2 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 111 0 0 0 -2.6 0.1 -1.8 -2.7 03/15/2005 18:10:00 3.4 0.4 4.2 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 111 0 0 0 -2.1 0.1 -1.3 -2.4 03/15/2005 18:20:00 3.6 0.4 4.2 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 111 0 0 0 -2.3 0 -1.8 -2.4 03/15/2005 18:30:00 2.6 0.6 4.2 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 1 0 0 -2.9 0.3 -2 -3.3 03/15/2005 18:40:00 2.2 0.4 3.4 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -3.5 0.1 -3.1 -3.8 03/15/2005 18:50:00 2.8 0.6 4.6 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 110 0 0 0 -3.6 0 -3.1 -3.8 03/15/2005 19:00:00 2.5 0.6 4.6 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 0 0 0 -3.6 0.1 -3.1 -3.8 03/15/2005 19:10:00 2.7 0.5 4.6 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 108 0 0 0 -3.9 0 -3.3 -4 03/15/2005 19:20:00 3 0.8 5.3 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 108 0 0 0 -3.9 0 -3.3 -4 03/15/2005 19:30:00 4.9 0.4 6.1 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 107 0 0 0 -4.1 0 -3.8 -4.2 03/15/2005 19:40:00 5 0.5 6.5 3.8 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 107 0 0 0 -4 0 -3.8 -4.2 03/15/2005 19:50:00 4.8 0.4 6.1 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 107 0 0 0 -3.9 0 -3.8 -4 03/15/2005 20:00:00 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 107 0 0 0 -3.8 0 -3.6 -3.8 03/15/2005 20:10:00 4.9 0.5 6.1 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 108 0 0 0 -3.5 0 -3.3 -3.8 03/15/2005 20:20:00 4.8 0.4 5.7 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 108 0 0 0 -3.3 0 -3.3 -3.6 03/15/2005 20:30:00 3.9 0.8 6.1 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -3.2 0 -2.9 -3.3 03/15/2005 20:40:00 4.8 0.7 6.5 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -3.1 0 -3.1 -3.3 03/15/2005 20:50:00 4.7 1 6.8 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -3.1 0 -2.7 -3.3 03/15/2005 21:00:00 5.2 0.6 6.8 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -3.1 0 -3.1 -3.3 03/15/2005 21:10:00 5.2 0.5 6.5 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -3.2 0 -3.1 -3.3 03/15/2005 21:20:00 5.4 0.5 6.8 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -3.2 0 -3.1 -3.3 03/15/2005 21:30:00 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -3.1 0 -3.1 -3.3 03/15/2005 21:40:00 5.6 0.4 6.8 4.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -3.1 0 -2.7 -3.1 03/15/2005 21:50:00 5.6 0.4 6.8 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -3 0 -2.9 -3.1 03/15/2005 22:00:00 5.6 0.5 7.6 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -3 0 -2.7 -3.1 03/15/2005 22:10:00 5.6 0.5 7.2 4.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 0 0 0 -2.8 0 -2.7 -2.9 03/15/2005 22:20:00 5.7 0.6 6.8 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 0 0 0 -3 0 -2.7 -3.1 03/15/2005 22:30:00 6.1 0.7 7.6 3.8 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 0 0 0 -3 0 -2.9 -3.1 03/15/2005 22:40:00 5.8 0.8 7.6 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 110 0 0 0 -3 0 -2.7 -3.1 03/15/2005 22:50:00 5 1 6.8 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -2.9 0 -2.7 -3.1 03/15/2005 23:00:00 4.6 1 6.5 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -2.8 0 -2.7 -3.1 03/15/2005 23:10:00 5.9 0.5 6.8 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -2.8 0 -2.4 -3.1 03/15/2005 23:20:00 5.1 0.8 6.5 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -2.8 0 -2.7 -2.9 03/15/2005 23:30:00 5.1 0.6 6.5 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 110 0 0 0 -2.8 0 -2.7 -2.7 03/15/2005 23:40:00 3.8 0.7 5.3 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 0 0 0 -2.7 0 -2.7 -2.7 03/15/2005 23:50:00 3.8 1 5.7 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 0 0 0 -2.7 0 -2.4 -2.7 03/16/2005 00:00:00 2.9 0.7 5.3 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 110 0 0 0 -2.7 0 -2 -2.7 03/16/2005 00:10:00 4 0.4 4.9 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 0 0 0 -2.7 0 -2 -2.9 03/16/2005 00:20:00 3.8 0.7 5.3 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 110 0 0 0 -2.7 0 -2.7 -2.7 03/16/2005 00:30:00 3.8 0.7 5.3 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -2.7 0 -2.7 -2.7 03/16/2005 00:40:00 3.5 0.7 4.9 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -2.7 0 -2.2 -2.7 03/16/2005 00:50:00 2.9 0.7 5.7 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -2.7 0 -2.7 -2.7 03/16/2005 01:00:00 3.8 1.3 6.8 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 109 0 0 0 -2.5 0.4 -1.8 -2.7 03/16/2005 01:10:00 5.5 0.8 6.8 2.6 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 157 0 157 305 110 0 0 0 -1.6 0 -1.3 -1.8 03/16/2005 01:20:00 5.2 0.9 6.5 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 0 0 0 -1.6 0 -1.1 -1.8 03/16/2005 01:30:00 5.6 0.7 6.8 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 0 0 0 -1.6 0 -1.5 -1.8 03/16/2005 01:40:00 5.7 0.7 6.8 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 0 0 0 -1.6 0 -1.1 -1.8 03/16/2005 01:50:00 5.8 0.6 6.8 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 110 0 0 0 -1.6 0 -1.3 -1.8 03/16/2005 02:00:00 6.1 0.5 7.2 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -1.5 0 -1.1 -1.5 03/16/2005 02:10:00 5.5 0.8 6.8 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -1.5 0 -1.3 -1.8 03/16/2005 02:20:00 4.7 1.1 6.8 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -1.5 0 -1.1 -1.8 03/16/2005 02:30:00 5.2 1.1 7.2 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 109 0 0 0 -1.5 0 -1.3 -1.5 03/16/2005 02:40:00 6.6 0.8 8 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 108 0 0 0 -1.4 0 -1.1 -1.8 03/16/2005 02:50:00 6.9 0.5 8 4.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 108 0 0 0 -1.6 0 -1.3 -1.8 03/16/2005 03:00:00 6.8 0.5 7.6 4.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 108 0 0 0 -1.6 0 -1.5 -1.8 03/16/2005 03:10:00 6.2 0.8 7.6 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 108 0 0 0 -1.6 0 -1.3 -1.8 03/16/2005 03:20:00 5.6 1.1 7.6 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 107 0 0 0 -1.6 0 -1.3 -1.8 03/16/2005 03:30:00 6.4 0.9 8.4 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 107 0 0 0 -1.6 0 -1.3 -1.8 03/16/2005 03:40:00 6.1 0.7 7.6 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 107 0 0 0 -1.7 0 -1.8 -2 03/16/2005 03:50:00 5.4 0.9 7.2 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 107 0 0 0 -1.8 0 -1.3 -2 03/16/2005 04:00:00 6.6 0.6 8 4.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 107 0 0 0 -2 0 -1.5 -2 03/16/2005 04:10:00 6.4 0.5 7.6 5.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 107 0 0 0 -2 0 -1.8 -2.2 03/16/2005 04:20:00 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 107 0 0 0 -2.3 0 -2 -2.7 03/16/2005 04:30:00 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 106 0 0 0 -2.4 0 -2.2 -2.7 03/16/2005 04:40:00 7.8 0.5 9.1 6.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 106 0 0 0 -2.2 0 -2 -2.4 03/16/2005 04:50:00 7.7 0.7 9.9 6.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 106 0 0 0 -2.1 0 -2 -2.2 03/16/2005 05:00:00 7.2 0.6 9.1 5.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 106 0 0 0 -2.1 0 -2 -2.2 03/16/2005 05:10:00 7.6 0.7 9.5 6.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 106 0 0 0 -2 0 -1.8 -2 03/16/2005 05:20:00 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 106 0 0 0 -1.9 0 -1.8 -2 03/16/2005 05:30:00 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 106 0 0 0 -2 0 -1.3 -2 03/16/2005 05:40:00 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 106 0 0 0 -2 0 -1.8 -2 03/16/2005 05:50:00 7.5 0.6 9.5 6.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 106 0 0 0 -2 0 -1.5 -2.2 03/16/2005 06:00:00 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 106 0 0 0 -2.2 0 -2 -2.4 03/16/2005 06:10:00 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 106 0 0 0 -2.7 0.1 -2.4 -2.7 03/16/2005 06:20:00 6.2 0.5 7.6 4.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 156 305 105 0 0 0 -2.8 0 -2.7 -3.1 03/16/2005 06:30:00 5.9 0.4 7.2 4.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 104 0 0 0 -3 0 -2.4 -3.1 03/16/2005 06:40:00 5.9 0.3 6.8 5.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 104 0 0 0 -2.9 0 -2.7 -3.1 03/16/2005 06:50:00 6.4 0.4 7.2 5.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 104 0 0 0 -3 0 -2.7 -3.1 03/16/2005 07:00:00 7.3 0.3 8 6.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 104 0 0 0 -3.2 0 -2.7 -3.3 03/16/2005 07:10:00 7.1 0.4 8.4 6.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 103 0 0 0 -3.4 0.1 -3.1 -3.8 03/16/2005 07:20:00 6.6 0.9 8 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 103 0 0 0 -3.6 0 -3.3 -3.8 03/16/2005 07:30:00 6.8 0.7 8 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 102 0 0 0 -3.6 0 -3.1 -3.8 03/16/2005 07:40:00 4.6 1.6 7.2 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 102 0 0 0 -4 0.3 -3.3 -4.5 03/16/2005 07:50:00 4.4 1.2 7.2 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 101 0 0 0 -4.2 0.1 -3.8 -4.5 03/16/2005 08:00:00 4.2 1 6.5 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 101 0 0 0 -4.1 0 -3.3 -4.2 03/16/2005 08:10:00 5.5 0.7 6.8 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 101 0 0 0 -3.7 0 -3.6 -3.8 03/16/2005 08:20:00 5.3 0.6 6.5 3.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 157 0 157 305 102 0 0 0 -3.6 0 -3.1 -3.8 03/16/2005 08:30:00 5.8 0.7 6.8 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 102 0 0 0 -3.3 0 -3.3 -3.6 03/16/2005 08:40:00 5.8 0.7 7.2 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 102 0 0 0 -3.4 0 -3.3 -3.6 03/16/2005 08:50:00 6.2 0.5 7.2 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 102 0 0 0 -3.3 0 -3.1 -3.3 03/16/2005 09:00:00 5.6 0.4 6.5 3.8 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 103 0 0 0 -3.3 0 -3.1 -3.3 03/16/2005 09:10:00 5.7 0.5 6.8 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 103 0 0 0 -3 0 -2.7 -3.1 03/16/2005 09:20:00 6.2 0.5 7.2 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 103 0 0 0 -2.7 0 -2.4 -2.9 03/16/2005 09:30:00 5.4 1.1 7.6 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 104 0 0 0 -2.6 0 -2.4 -2.7 03/16/2005 09:40:00 4.5 0.9 6.5 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 104 0 0 0 -2.7 0 -2.4 -2.7 03/16/2005 09:50:00 6 1.5 8.4 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 104 0 0 0 -2.5 0.1 -2.2 -2.7 03/16/2005 10:00:00 7.7 0.6 8.8 4.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 104 0 0 0 -2.3 0 -2.2 -2.7 03/16/2005 10:10:00 7.5 0.6 8.4 5.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 105 0 0 0 -2.7 0 -2.4 -2.9 03/16/2005 10:20:00 7.5 0.5 8.8 5.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 105 0 0 0 -3 0.1 -2.7 -3.3 03/16/2005 10:30:00 7.9 0.4 8.8 5.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 104 0 0 0 -3.2 0 -3.1 -3.3 03/16/2005 10:40:00 8 0.4 8.8 6.8 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 157 305 104 0 0 0 -3 0 -2.7 -3.1 03/16/2005 10:50:00 7.5 0.3 8.4 6.8 7.5 1.4 8.8 0.4 0.4 0 0.4 0.4 157 0 157 305 105 0 105 0 -2.7 0 -2.7 -2.9 03/16/2005 11:00:00 7.4 0.4 8.8 6.1 7.6 0.4 8.8 6.5 0.4 0 0.4 0.4 157 0 157 305 106 0 106 0 -2.8 0 -2.7 -3.1 03/16/2005 11:10:00 7.3 0.4 8.4 6.1 7.6 0.4 8.8 6.5 0.4 0 0.4 0.4 157 0 157 305 106 0 106 0 -2.7 0 -2.4 -2.9 03/16/2005 11:20:00 7.6 0.4 8.4 6.5 7.8 0.4 8.8 6.5 0.4 0 0.4 0.4 157 0 157 305 107 0 107 0 -2.8 0 -2.7 -3.1 03/16/2005 11:30:00 7.3 0.4 8.4 6.5 7.5 0.4 8.8 6.5 0.4 0 0.4 0.4 157 0 158 305 107 0 107 0 -2.7 0 -2.4 -2.9 03/16/2005 11:40:00 7 0.3 7.6 6.5 7.4 0.3 8 6.5 0.4 0 0.4 0.4 157 0 157 305 107 0 107 0 -2.8 0 -2.7 -2.9 03/16/2005 11:50:00 7.2 0.3 8 6.5 7.5 0.3 8.4 6.5 0.4 0 0.4 0.4 157 0 158 305 106 0 107 0 -2.8 0 -2.7 -2.7 03/16/2005 12:00:00 7.4 0.3 8 6.5 7.6 0.3 8.4 6.5 0.4 0 0.4 0.4 157 0 158 305 105 0 105 0 -2.7 0 -2.4 -2.7 03/16/2005 12:10:00 7.4 0.3 8.4 6.5 7.7 0.3 8.4 6.8 0.4 0 0.4 0.4 157 0 158 305 105 0 105 0 -2.4 0 -2.2 -2.7 03/16/2005 12:20:00 7.1 0.3 8 6.5 7.3 0.3 8 6.5 0.4 0 0.4 0.4 157 0 158 305 105 0 106 0 -2.4 0 -2 -2.7 03/16/2005 12:30:00 6.8 0.4 8 5.3 7 0.4 8 6.1 0.4 0 0.4 0.4 157 0 158 305 104 0 104 0 -2.3 0 -2 -2.4 03/16/2005 12:40:00 6.4 0.4 7.2 5.7 6.3 0.5 7.2 3.8 0.4 0 0.4 0.4 157 0 158 305 104 0 105 0 -2.1 0.1 -1.8 -2.4 03/16/2005 12:50:00 6.9 0.5 8 5.7 6.7 0.6 8.4 4.6 0.4 0 0.4 0.4 157 0 158 305 104 0 104 0 -1.7 0.1 -1.3 -2 03/16/2005 13:00:00 7.3 0.5 8.8 6.1 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 157 0 158 305 104 0 104 0 -1.5 0 -1.3 -1.8 03/16/2005 13:10:00 7.1 0.5 8.4 5.7 6.9 0.6 8.8 5.3 0.4 0 0.4 0.4 157 0 158 305 103 0 103 0 -1.4 0 -1.3 -1.3 03/16/2005 13:20:00 6.8 0.5 8 5.7 6.6 0.5 8 4.9 0.4 0 0.4 0.4 157 0 158 305 102 0 102 0 -1.4 0 -0.8 -1.3 03/16/2005 13:30:00 6.7 0.4 8 5.3 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 157 0 158 305 102 0 102 0 -1.4 0 -0.8 -1.5 03/16/2005 13:40:00 6.9 0.4 8 5.7 6.6 0.5 8 5.3 0.4 0 0.4 0.4 158 0 158 305 104 2 103 0 -1.4 0.1 -0.6 -1.5 03/16/2005 13:50:00 6.7 0.4 7.6 5.3 6.5 0.4 7.2 4.9 0.4 0 0.4 0.4 158 0 158 305 110 2 108 0 -1.4 0.1 -1.1 -1.8 03/16/2005 14:00:00 7 0.3 8 6.1 7.1 0.4 8 5.7 0.4 0 0.4 0.4 159 0 159 305 123 9 120 0 -1.6 0 -1.3 -1.8 03/16/2005 14:10:00 7.4 0.4 8 6.5 7.5 0.4 8.4 6.8 0.4 0 0.4 0.4 162 5 159 305 142 1 142 0 -1.4 0 -1.1 -1.5 03/16/2005 14:20:00 7.4 0.4 8.8 6.5 7.3 0.4 8.4 6.1 0.4 0 0.4 0.4 181 6 186 305 147 2 149 0 -1.1 0 -1.1 -1.3 03/16/2005 14:30:00 6.9 0.5 8.4 5.3 6.6 0.5 8.8 4.9 0.4 0 0.4 0.4 191 0 192 305 150 0 150 0 -1.2 0 -1.1 -1.3 03/16/2005 14:40:00 7.2 0.4 8.4 6.1 7 0.5 8.4 4.9 0.4 0 0.4 0.4 192 1 192 305 151 0 151 0 -1.4 0 -1.1 -1.5 03/16/2005 14:50:00 7.6 0.4 9.1 6.5 7.6 0.5 8.8 5.3 0.4 0.4 3.8 0.4 196 0 196 305 151 0 151 0 -0.8 0.2 -0.6 -1.3 03/16/2005 15:00:00 7 0.5 8.4 6.1 7 0.5 8.4 5.7 5.6 1.2 8 0.4 198 2 199 305 152 2 152 0 -0.6 0 0.1 -0.8 03/16/2005 15:10:00 7.5 0.5 9.1 6.5 7.4 0.5 9.1 5.3 6.5 0.8 9.1 3.4 199 2 205 305 157 1 158 0 -0.7 0 -0.4 -0.8 03/16/2005 15:20:00 6.5 0.4 7.2 5.3 6.6 0.5 7.6 4.9 6.6 0.5 7.6 4.2 192 2 194 305 153 4 150 0 -1 0.1 -0.4 -1.1 03/16/2005 15:30:00 6.3 0.5 7.2 4.9 6.5 0.6 7.2 4.2 5 2.6 7.6 0.4 192 2 192 305 138 12 154 0 -1 0 -0.6 -1.1 03/16/2005 15:40:00 6.4 0.4 7.6 5.7 6.7 0.3 7.6 5.7 6.3 1.6 7.6 0.4 192 2 192 305 124 1 124 0 -1 0.1 -0.4 -1.1 03/16/2005 15:50:00 6.6 0.3 7.6 5.7 6.9 0.3 8 6.1 2 2.6 7.6 0.4 191 2 194 305 129 2 130 0 -1.1 0 -0.6 -1.1 03/16/2005 16:00:00 6.8 0.3 7.6 6.1 7.1 0.3 8 6.5 0.4 0 0.4 0.4 189 2 190 305 134 1 135 0 -1.1 0 -0.6 -1.3 03/16/2005 16:10:00 7.1 0.2 7.6 6.5 7.4 0.2 8 6.5 0.4 0 0.4 0.4 190 2 189 305 136 0 136 0 -1.1 0 -0.6 -1.3 03/16/2005 16:20:00 6.6 0.2 7.2 6.1 6.8 0.3 7.6 6.1 0.4 0 0.4 0.4 193 2 192 305 135 1 136 0 -1.1 0 -0.6 -1.3 03/16/2005 16:30:00 6.7 0.2 7.2 6.5 7 0.2 7.6 6.5 1.1 2.1 7.2 0.4 190 2 191 305 145 35 133 0 -1.1 0 -0.6 -1.3 03/16/2005 16:40:00 6.9 0.2 7.6 6.5 7.1 0.2 7.6 6.5 2.8 3.2 7.6 0.4 191 3 191 305 185 32 214 0 -1.3 0.1 -0.8 -1.5 03/16/2005 16:50:00 6.8 0.2 7.2 6.1 7 0.2 7.6 6.5 0.4 0 0.4 0.4 190 1 191 305 194 1 194 0 -1.5 0 -1.1 -1.5 03/16/2005 17:00:00 6.9 0.2 7.6 6.5 7.1 0.2 7.6 6.1 0.4 0 0.4 0.4 190 0 190 305 196 0 196 0 -1.5 0.1 -1.1 -1.8 03/16/2005 17:10:00 6.5 0.2 6.8 6.1 6.7 0.2 7.2 6.1 0.4 0 0.4 0.4 191 0 190 305 195 1 196 0 -1.5 0 -1.1 -1.8 03/16/2005 17:20:00 6.3 0.2 6.8 5.7 6.5 0.3 7.2 5.7 2.9 2.9 7.2 0.4 191 0 192 305 194 1 194 0 -1.4 0 -1.1 -1.5 03/16/2005 17:30:00 6.7 0.5 8 4.2 7.1 0.4 8.4 6.5 5.1 2.6 8.8 0.4 187 4 186 305 192 3 186 0 -1.4 0 -1.1 -1.5 03/16/2005 17:40:00 7.2 0.3 8 6.1 7.6 0.3 8.4 6.8 6.5 2.1 8.4 0.4 185 2 183 305 190 1 188 0 -1.5 0.1 -1.1 -1.5 03/16/2005 17:50:00 7.5 0.3 8 6.8 7.8 0.2 8.4 7.2 7.8 0.3 8.4 6.8 188 2 188 305 191 1 191 0 -1.4 0 -1.1 -1.5 03/16/2005 18:00:00 6.7 0.6 8 3.8 7.4 0.4 8.4 6.5 7.4 0.4 8.4 5.3 182 3 181 305 186 2 186 0 -1.2 0 -0.6 -1.5 03/16/2005 18:10:00 6.9 0.8 8 3.4 7.5 0.5 8.4 5.3 7.4 0.8 8.4 1.9 184 3 186 305 187 2 185 0 -1.3 0.2 -0.6 -1.8 03/16/2005 18:20:00 7 0.3 7.6 6.1 7.4 0.3 8 6.5 7.3 0.4 8 4.6 187 2 186 305 189 1 188 0 -1.5 0 -1.1 -1.8 03/16/2005 18:30:00 6.7 0.3 7.2 6.1 7.1 0.3 8 6.5 7.1 0.3 8 6.1 187 1 188 305 188 1 187 0 -1.7 0 -1.3 -2 03/16/2005 18:40:00 5.9 1 7.2 2.6 6.7 0.7 8 4.6 6.1 1.6 8 0.7 181 3 185 305 185 2 186 0 -1.9 0 -1.8 -2 03/16/2005 18:50:00 4.7 1 6.8 2.6 5.6 0.6 6.8 3.8 3.1 2.1 6.8 0.4 177 6 183 305 182 3 185 0 -2 0.1 -1.5 -2.2 03/16/2005 19:00:00 4.7 1 6.5 2.3 5.4 0.5 7.2 4.2 3 2.1 6.5 0.4 180 4 183 305 182 2 181 0 -1.9 0 -1.8 -2 03/16/2005 19:10:00 6.4 0.5 7.2 3.8 6.8 0.4 7.6 5.3 5 2.1 7.6 0.4 183 1 184 305 184 1 184 0 -1.9 0 -1.3 -2 03/16/2005 19:20:00 4.7 1.1 7.2 2.6 5.5 0.7 7.6 4.2 2.4 2.3 7.6 0.4 180 5 184 305 154 16 182 0 -1.9 0.1 -1.3 -2 03/16/2005 19:30:00 6.6 0.4 7.6 5.3 7 0.4 8 6.1 2.8 2.9 8 0.4 189 2 188 305 142 0 142 0 -1.8 0 -1.8 -2 03/16/2005 19:40:00 6.4 0.5 7.6 4.9 6.7 0.5 8 5.3 5.8 2.3 8 0.4 189 1 190 305 135 12 141 0 -1.8 0 -1.3 -2 03/16/2005 19:50:00 5.1 1 6.5 2.3 5.6 0.7 6.8 3.8 1.4 2.2 6.8 0.4 188 2 191 305 105 2 109 0 -2 0 -1.8 -2 03/16/2005 20:00:00 4.5 0.7 5.7 2.3 5.1 0.5 6.1 3.4 0.4 0 0.4 0.4 183 0 183 305 100 1 101 0 -2 0.1 -1.5 -2.2 03/16/2005 20:10:00 3.6 0.7 5.3 1.9 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 179 2 179 305 97 1 97 0 -2 0.1 -1.5 -2.2 03/16/2005 20:20:00 3.7 0.7 5.3 2.3 5.3 0.5 6.5 3.8 0.4 0 0.4 0.4 176 1 177 305 95 0 95 0 -2 0.2 -1.3 -2 03/16/2005 20:30:00 3.3 0.8 5.3 1.9 4.6 0.5 5.7 3.4 0.4 0 0.4 0.4 176 0 177 305 94 0 95 0 -2 0.1 -1.3 -2.2 03/16/2005 20:40:00 3.3 0.7 4.9 1.9 4.6 0.4 5.7 3.8 0.4 0 0.4 0.4 177 0 177 305 93 0 92 0 -1.8 0.1 -1.3 -2 03/16/2005 20:50:00 4.7 1.3 7.6 2.3 5.7 0.9 7.6 3.8 0.4 0 0.4 0.4 168 8 161 305 91 1 90 0 -1.9 0.2 -1.1 -2.4 03/16/2005 21:00:00 4.8 1 6.8 2.6 6.1 0.5 7.2 3.4 0.4 0 0.4 0.4 163 5 160 305 88 1 90 0 -2.7 0.2 -2 -3.1 03/16/2005 21:10:00 4.5 0.8 6.1 2.6 5.9 0.4 7.2 4.9 0.4 0 0.4 0.4 165 4 163 305 87 0 86 0 -2.8 0.1 -2.2 -3.1 03/16/2005 21:20:00 4.4 0.8 6.5 2.6 5.7 0.5 7.2 4.6 0.4 0 0.4 0.4 165 6 159 305 85 1 86 0 -2.8 0 -2.2 -2.9 03/16/2005 21:30:00 4.4 0.8 6.5 2.6 5.8 0.4 6.8 4.6 0.4 0 0.4 0.4 165 6 159 305 85 0 85 0 -2.7 0 -2.4 -2.9 03/16/2005 21:40:00 5 0.9 7.6 2.3 6.1 0.5 7.6 4.6 0.4 0 0.4 0.4 161 7 152 305 84 0 85 0 -2.4 0.2 -2 -2.7 03/16/2005 21:50:00 6.4 1 9.5 3.4 6.9 0.7 9.5 5.3 0.4 0 0.4 0.4 156 6 154 305 83 1 82 0 -2.5 0.2 -2 -2.7 03/16/2005 22:00:00 7.2 1 9.1 4.2 7.8 0.5 9.1 6.1 0.4 0 0.4 0.4 155 7 152 305 82 1 83 0 -3 0.1 -2.7 -3.1 03/16/2005 22:10:00 9.4 0.8 11.5 7.2 9.2 0.7 11.1 7.6 0.4 0 0.4 0.4 146 2 152 305 80 0 80 0 -3.3 0 -3.1 -3.6 03/16/2005 22:20:00 9.7 0.6 11.1 6.5 9.5 0.6 11.1 7.6 0.4 0 0.4 0.4 145 2 152 305 79 0 79 0 -3.5 0 -3.3 -3.8 03/16/2005 22:30:00 9.5 0.9 11.5 6.5 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 146 4 144 305 79 0 79 0 -3.6 0 -3.3 -3.8 03/16/2005 22:40:00 9.4 1 11.5 4.9 9.4 0.8 11.1 6.8 0.4 0 0.4 0.4 145 5 141 305 78 0 78 0 -3.8 0 -3.3 -3.8 03/16/2005 22:50:00 9.1 1 11.5 5.7 9.3 0.9 11.8 6.1 0.4 0 0.4 0.4 145 7 151 305 77 1 78 0 -3.7 0.1 -3.3 -4 03/16/2005 23:00:00 8.9 1.2 11.5 4.6 9 1 11.1 5.7 0.4 0 0.4 0.4 150 7 156 305 76 1 77 0 -3.9 0 -3.8 -4.2 03/16/2005 23:10:00 9.4 1 11.5 4.9 9.6 0.8 11.5 6.8 0.4 0 0.4 0.4 145 6 142 305 74 0 75 0 -4.1 0.1 -3.8 -4.5 03/16/2005 23:20:00 9.6 1 12.2 6.8 9.7 0.9 11.8 7.2 0.4 0 0.4 0.4 143 8 136 305 73 1 74 0 -4.3 0 -4 -4.5 03/16/2005 23:30:00 10 1.1 14.1 6.8 10.1 1 12.6 6.8 0.4 0 0.4 0.4 142 7 139 305 73 0 74 0 -4.3 0.1 -4 -4.5 03/16/2005 23:40:00 10 1 13 7.2 10 0.9 12.2 7.6 0.4 0 0.4 0.4 152 6 152 305 74 0 73 0 -4.1 0 -3.8 -4.5 03/16/2005 23:50:00 8.6 1.4 12.2 5.3 9.8 0.8 11.8 7.2 0.4 0 0.4 0.4 159 5 160 305 74 0 74 0 -4.1 0 -4 -4.2 03/17/2005 00:00:00 9.4 1.2 11.5 5.7 9.7 0.7 11.1 7.6 0.4 0 0.4 0.4 156 5 156 305 74 0 73 0 -4.3 0 -3.8 -4.5 03/17/2005 00:10:00 10.1 0.7 11.8 8 9.9 0.7 11.5 7.6 0.4 0 0.4 0.4 152 3 148 305 73 0 73 0 -4.4 0 -4.2 -4.5 03/17/2005 00:20:00 10.3 0.7 12.2 8 10 0.8 11.5 8 0.4 0 0.4 0.4 149 3 150 305 72 0 72 0 -4.5 0 -3.8 -4.7 03/17/2005 00:30:00 10.8 0.5 12.2 9.1 10.6 0.5 11.8 8.8 0.4 0 0.4 0.4 142 2 140 305 70 1 71 0 -4.8 0.1 -4.5 -5.1 03/17/2005 00:40:00 11.8 0.5 13 9.1 11.4 0.5 12.6 9.5 0.4 0 0.4 0.4 141 1 141 305 66 1 67 0 -5.3 0.1 -4.9 -5.6 03/17/2005 00:50:00 12.5 0.4 13.3 11.1 11.9 0.5 13 10.3 0.4 0 0.4 0.4 142 2 140 305 63 0 63 0 -5.5 0 -5.3 -5.6 03/17/2005 01:00:00 12 0.5 13.3 10.3 11.6 0.6 13 9.5 0.4 0 0.4 0.4 145 1 145 305 63 0 63 0 -5.3 0 -4.9 -5.6 03/17/2005 01:10:00 12 0.6 14.1 10.3 11.5 0.7 13.3 9.5 0.4 0 0.4 0.4 144 2 143 305 65 0 64 0 -5 0 -4.9 -5.1 03/17/2005 01:20:00 11.4 0.5 13 9.9 11 0.6 12.2 9.5 0.4 0 0.4 0.4 143 2 141 305 65 0 65 0 -5.1 0 -4.9 -5.3 03/17/2005 01:30:00 11.6 0.6 12.6 9.5 11.3 0.5 12.6 9.9 0.4 0 0.4 0.4 143 2 144 305 66 0 66 0 -5 0 -4.7 -5.1 03/17/2005 01:40:00 10.7 0.6 12.2 8.8 10.5 0.6 12.2 8.4 0.4 0 0.4 0.4 146 3 143 305 67 0 67 0 -4.9 0.1 -4.7 -4.9 03/17/2005 01:50:00 10 1 12.6 6.8 10.2 0.9 12.2 7.2 0.4 0 0.4 0.4 146 5 142 305 69 0 67 0 -4.5 0 -4.5 -4.7 03/17/2005 02:00:00 10.2 1.1 12.2 5.3 10.3 1 12.6 6.5 0.4 0 0.4 0.4 144 6 150 305 69 0 69 0 -4.6 0 -4.5 -4.7 03/17/2005 02:10:00 9.8 0.8 11.5 6.8 9.9 0.7 11.8 7.6 0.4 0 0.4 0.4 143 4 143 305 69 0 69 0 -4.6 0 -4.5 -4.7 03/17/2005 02:20:00 9.5 0.8 11.1 6.5 9.4 0.8 11.1 7.2 0.4 0 0.4 0.4 147 5 146 305 68 0 69 0 -4.6 0 -4.5 -4.7 03/17/2005 02:30:00 9.4 0.8 11.8 6.8 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 150 4 154 305 68 0 68 0 -4.7 0 -4.5 -4.7 03/17/2005 02:40:00 9.1 0.9 10.7 5.7 9.3 0.7 10.7 7.2 0.4 0 0.4 0.4 147 5 147 305 69 0 68 0 -4.5 0 -4.2 -4.7 03/17/2005 02:50:00 7.7 1.1 10.3 4.6 8.3 0.9 10.3 6.1 0.4 0 0.4 0.4 151 7 141 305 68 0 69 0 -4.7 0 -4.5 -4.9 03/17/2005 03:00:00 6.6 1.3 8.8 3.4 7.7 0.6 8.8 5.7 0.4 0 0.4 0.4 158 7 152 305 67 1 68 0 -5 0 -4.7 -5.1 03/17/2005 03:10:00 7 1.2 9.1 3.4 8 0.6 9.1 4.9 0.4 0 0.4 0.4 157 6 155 305 64 1 64 0 -5.3 0.1 -5.1 -5.6 03/17/2005 03:20:00 6.7 1.2 9.5 3.4 7.9 0.7 9.1 4.9 0.4 0 0.4 0.4 156 7 151 305 62 0 62 0 -5.5 0 -5.3 -5.6 03/17/2005 03:30:00 8.1 1.2 10.3 4.2 8.4 1 10.7 5.7 0.4 0 0.4 0.4 150 7 147 305 61 0 60 0 -5.5 0 -5.1 -5.8 03/17/2005 03:40:00 9.9 1 11.8 4.9 9.7 0.7 11.1 6.8 0.4 0 0.4 0.4 145 5 144 305 60 0 60 0 -5.6 0 -5.6 -5.8 03/17/2005 03:50:00 10.8 0.3 11.5 9.1 10.1 0.4 11.1 8.8 0.4 0 0.4 0.4 143 0 144 305 60 0 60 0 -5.5 0 -5.3 -5.6 03/17/2005 04:00:00 11 0.4 12.2 9.9 10.3 0.5 11.5 9.1 0.4 0 0.4 0.4 142 1 140 305 61 1 62 0 -5.2 0 -4.9 -5.6 03/17/2005 04:10:00 10.5 0.6 12.2 7.2 10.1 0.5 11.5 8.8 0.4 0 0.4 0.4 142 2 139 305 63 0 63 0 -5.1 0 -4.9 -5.3 03/17/2005 04:20:00 10.3 0.6 11.5 8.4 9.9 0.5 11.1 8.4 0.4 0 0.4 0.4 143 3 137 305 63 0 63 0 -5.1 0 -4.9 -5.3 03/17/2005 04:30:00 9.8 1 11.8 6.5 9.7 0.7 11.1 6.5 0.4 0 0.4 0.4 145 5 147 305 63 0 63 0 -5.1 0 -4.9 -5.3 03/17/2005 04:40:00 10.3 0.8 12.2 7.2 9.9 0.5 11.1 8 0.4 0 0.4 0.4 143 3 142 305 63 0 62 0 -5.1 0 -5.1 -5.3 03/17/2005 04:50:00 10.7 0.5 11.8 8.8 10 0.4 11.1 8.8 0.4 0 0.4 0.4 143 1 142 305 62 0 62 0 -5.3 0 -5.1 -5.6 03/17/2005 05:00:00 10.7 0.4 11.5 8.4 10.1 0.4 10.7 8.8 0.4 0 0.4 0.4 141 1 141 305 61 0 62 0 -5.4 0 -5.1 -5.6 03/17/2005 05:10:00 10.4 0.5 11.5 8 9.8 0.4 10.7 8.8 0.4 0 0.4 0.4 142 1 141 305 60 0 60 0 -5.4 0 -5.1 -5.6 03/17/2005 05:20:00 10.3 0.7 11.5 7.6 10 0.4 11.1 8.4 0.4 0 0.4 0.4 142 2 142 305 60 0 60 0 -5.5 0 -5.1 -5.8 03/17/2005 05:30:00 10.4 0.6 11.5 6.5 10 0.4 11.1 8.4 0.4 0 0.4 0.4 141 3 143 305 58 1 58 0 -5.8 0.1 -5.6 -6 03/17/2005 05:40:00 11.6 0.5 13 10.7 10.9 0.4 11.8 9.9 0.4 0 0.4 0.4 141 0 141 305 56 0 55 0 -6.1 0 -5.8 -6.2 03/17/2005 05:50:00 12.1 0.4 13 11.1 11.4 0.3 12.2 10.3 0.4 0 0.4 0.4 142 1 141 305 55 0 55 0 -6.1 0 -6 -6.2 03/17/2005 06:00:00 11.9 0.4 13 10.3 11.2 0.4 12.2 9.9 0.4 0 0.4 0.4 144 1 143 305 55 0 54 0 -6.1 0 -6 -6.2 03/17/2005 06:10:00 11.6 0.3 12.2 11.1 10.8 0.3 11.5 9.9 0.4 0 0.4 0.4 142 1 143 305 53 0 54 0 -6.4 0.1 -6.2 -6.7 03/17/2005 06:20:00 11.6 0.3 12.2 10.7 10.7 0.3 11.5 9.9 0.4 0 0.4 0.4 140 0 140 305 52 0 52 0 -6.5 0 -6.4 -6.7 03/17/2005 06:30:00 11.5 0.5 13 9.9 10.7 0.4 11.8 9.5 0.4 0 0.4 0.4 140 1 140 305 52 0 51 0 -6.4 0 -6.2 -6.7 03/17/2005 06:40:00 10.6 0.5 11.8 9.1 10.2 0.3 11.1 9.5 0.4 0 0.4 0.4 142 2 141 305 51 0 51 0 -6.5 0 -6.4 -6.7 03/17/2005 06:50:00 10.2 0.6 11.5 8.8 10.1 0.3 10.7 9.1 0.4 0 0.4 0.4 144 3 142 305 51 0 51 0 -6.4 0 -6.2 -6.7 03/17/2005 07:00:00 11.2 0.3 11.8 9.9 10.3 0.3 11.1 9.5 0.4 0 0.4 0.4 142 1 143 305 52 0 52 0 -6.2 0 -6 -6.4 03/17/2005 07:10:00 11.1 0.3 11.8 9.9 10.1 0.4 11.1 8.8 0.4 0 0.4 0.4 141 1 141 305 52 0 53 0 -6.4 0 -6.2 -6.7 03/17/2005 07:20:00 11.3 0.3 12.2 10.3 10.2 0.4 11.1 9.1 0.4 0 0.4 0.4 140 1 141 305 53 0 52 0 -6.2 0 -6 -6.4 03/17/2005 07:30:00 11.1 0.4 11.8 9.5 10.4 0.3 11.1 9.1 0.4 0 0.4 0.4 144 1 143 305 54 0 54 0 -6.1 0 -6 -6.2 03/17/2005 07:40:00 11 0.4 11.8 9.9 10.2 0.4 11.1 9.1 0.4 0 0.4 0.4 143 2 143 305 54 0 54 0 -6.1 0 -6 -6.2 03/17/2005 07:50:00 10.5 0.5 11.8 9.5 9.9 0.3 10.7 9.1 0.4 0 0.4 0.4 144 3 140 305 54 0 53 0 -6.1 0 -6 -6.2 03/17/2005 08:00:00 11.3 0.3 12.2 10.3 10.1 0.4 11.1 8.8 0.4 0 0.4 0.4 142 1 143 305 54 0 54 0 -6.2 0 -6 -6.2 03/17/2005 08:10:00 11.2 0.6 12.2 9.5 10.2 0.4 10.7 8.8 0.4 0 0.4 0.4 143 2 141 305 54 0 53 0 -6.1 0 -6 -6.2 03/17/2005 08:20:00 11 0.6 12.2 9.5 10 0.4 10.7 8.8 0.4 0 0.4 0.4 143 1 143 305 54 0 54 0 -6.1 0 -6 -6.2 03/17/2005 08:30:00 11.9 0.4 13 10.7 10.2 0.5 11.1 8.8 0.4 0 0.4 0.4 143 1 143 305 54 0 53 0 -6.1 0 -6 -6.2 03/17/2005 08:40:00 12.3 0.4 13 11.1 10.4 0.4 11.5 9.1 0.4 0 0.4 0.4 142 1 142 305 53 0 53 0 -6.2 0 -5.6 -6.4 03/17/2005 08:50:00 11.7 0.6 13 10.3 10 0.5 11.1 8.8 0.4 0 0.4 0.4 145 3 143 305 55 0 54 0 -5.9 0.1 -5.6 -6 03/17/2005 09:00:00 11 0.5 12.2 9.5 9.6 0.5 10.7 7.6 0.4 0 0.4 0.4 147 3 148 305 56 1 55 0 -5.6 0.1 -5.6 -6 03/17/2005 09:10:00 9.9 0.8 11.8 8 8.5 0.6 10.3 6.8 0.4 0 0.4 0.4 145 3 143 305 58 0 58 0 -5.5 0 -5.6 -5.6 03/17/2005 09:20:00 9.6 0.6 11.5 8 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 147 3 146 305 59 0 59 0 -5.6 0 -5.6 -5.8 03/17/2005 09:30:00 9.6 0.6 11.5 7.6 8.4 0.5 9.9 6.5 0.4 0 0.4 0.4 147 3 145 305 60 0 60 0 -5.5 0 -5.3 -5.6 03/17/2005 09:40:00 9.1 0.7 10.7 5.3 7.9 0.6 9.9 6.5 0.4 0 0.4 0.4 147 5 145 305 59 0 59 0 -5.6 0 -5.6 -5.8 03/17/2005 09:50:00 9.6 0.5 10.7 6.8 8.4 0.5 9.5 6.5 0.4 0 0.4 0.4 147 2 146 305 60 0 59 0 -5.5 0 -5.3 -5.6 03/17/2005 10:00:00 9.5 0.5 10.7 7.6 8.4 0.4 9.5 6.8 0.4 0 0.4 0.4 148 2 149 305 61 0 60 0 -5.3 0 -5.1 -5.6 03/17/2005 10:10:00 8.9 0.5 10.7 7.6 7.9 0.5 8.8 6.5 0.4 0 0.4 0.4 150 3 152 305 62 0 62 0 -5.1 0 -4.9 -5.3 03/17/2005 10:20:00 9.1 0.3 9.9 8 8 0.4 8.8 6.8 0.4 0 0.4 0.4 146 2 150 305 63 0 63 0 -5 0 -4.9 -5.1 03/17/2005 10:30:00 9.1 0.6 10.3 7.2 8 0.4 8.8 6.1 0.4 0 0.4 0.4 146 1 145 305 64 0 64 0 -5 0 -4.7 -5.1 03/17/2005 10:40:00 8.3 0.5 9.5 6.1 7.4 0.4 8.4 5.7 0.4 0 0.4 0.4 145 1 145 305 66 0 66 0 -4.9 0 -4.7 -4.9 03/17/2005 10:50:00 7.9 0.6 9.5 5.3 7.1 0.4 8 5.3 0.4 0 0.4 0.4 146 1 145 305 67 0 67 0 -4.9 0 -4.7 -4.9 03/17/2005 11:00:00 7.3 0.8 8.8 4.2 7 0.4 8 5.3 0.4 0 0.4 0.4 145 0 145 305 68 0 68 0 -4.9 0 -4.7 -5.1 03/17/2005 11:10:00 8 0.6 9.1 5.3 7.2 0.4 8 5.7 0.4 0 0.4 0.4 145 0 145 305 67 0 67 0 -5 0 -4.9 -5.1 03/17/2005 11:20:00 6.4 1 8.4 3.4 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 145 0 145 305 68 0 67 0 -5 0 -4.7 -5.1 03/17/2005 11:30:00 5.9 0.9 8.4 3.4 5.8 0.6 7.2 4.6 0.4 0 0.4 0.4 149 7 145 305 69 0 69 0 -4.9 0 -4.7 -5.1 03/17/2005 11:40:00 5.6 1 8.4 3.4 5.6 0.8 7.2 3 0.4 0 0.4 0.4 153 9 146 305 70 0 71 0 -5 0 -4.7 -5.1 03/17/2005 11:50:00 5.4 1 7.2 3 5.7 0.7 7.2 3.4 0.4 0 0.4 0.4 147 9 140 305 71 0 71 0 -4.9 0 -4.7 -4.9 03/17/2005 12:00:00 5.9 1 8 2.6 6 0.7 7.2 3.4 0.4 0 0.4 0.4 144 9 150 305 71 0 71 0 -5 0 -4.7 -5.1 03/17/2005 12:10:00 4.8 1.1 7.2 1.5 4.9 0.9 7.6 2.6 0.4 0 0.4 0.4 141 13 138 305 71 1 71 0 -4.7 0.1 -4.2 -5.1 03/17/2005 12:20:00 5.3 1 7.2 2.6 5.2 0.7 6.8 3 0.4 0 0.4 0.4 132 9 134 305 75 1 76 0 -4.2 0 -4 -4.5 03/17/2005 12:30:00 6 1.2 8.4 2.6 5.5 1 8.4 2.6 0.4 0 0.4 0.4 136 12 129 305 79 1 79 0 -4.1 0 -4 -4.2 03/17/2005 12:40:00 6.1 1.4 8.8 2.3 5.6 1 7.6 2.6 0.4 0 0.4 0.4 140 13 139 305 84 2 84 0 -3.9 0 -3.6 -4 03/17/2005 12:50:00 5.8 1.7 9.9 1.9 5.3 1.3 8 0.7 0.4 0 0.4 0.4 140 13 142 305 95 4 99 0 -3.4 0 -3.3 -3.8 03/17/2005 13:00:00 6 1.5 9.5 2.6 5.3 1.1 7.6 2.6 0.4 0 0.4 0.4 139 13 140 305 105 5 100 0 -3.3 0.2 -3.1 -3.8 03/17/2005 13:10:00 7.3 1.3 9.9 4.2 6.2 0.8 8 3.4 0.4 0 0.4 0.4 139 9 140 305 119 3 122 0 -3.2 0 -3.1 -3.3 03/17/2005 13:20:00 4.7 1.6 8.4 0.4 4.1 1.4 6.8 0.4 0.4 0 0.4 0.4 136 17 129 305 127 3 127 0 -2.4 0.5 -1.5 -3.1 03/17/2005 13:30:00 3.8 1.1 6.5 1.1 3.2 1 5.3 0.7 0.4 0 0.4 0.4 135 17 144 305 136 5 135 0 -1.1 0.2 -0.6 -1.5 03/17/2005 13:40:00 3.9 0.9 6.5 1.5 3.2 0.7 5.3 1.9 0.4 0 0.4 0.4 126 15 130 305 153 7 156 0 -1.4 0.4 -0.8 -2.2 03/17/2005 13:50:00 1.8 1 4.6 0.4 1.8 0.7 3.8 0.4 0.4 0 0.4 0.4 150 15 144 305 169 8 168 0 -1.6 0.2 -1.1 -2.2 03/17/2005 14:00:00 1.1 0.6 3 0.4 1.2 0.4 2.3 0.4 0.4 0 0.4 0.4 26 38 118 305 104 15 156 0 -1.3 0.1 -0.6 -1.5 03/17/2005 14:10:00 1.3 0.6 2.3 0.4 1.4 0.5 2.3 0.4 0.4 0 0.4 0.4 20 32 7 305 98 17 87 0 -1.6 0 -1.1 -2 03/17/2005 14:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 93 112 103 305 137 58 134 0 -0.9 0.3 -0.1 -1.8 03/17/2005 14:30:00 1 0.6 2.6 0.4 1.4 0.6 3 0.4 0.4 0 0.4 0.4 19 27 54 305 99 14 107 0 -1.3 0.3 -0.4 -1.8 03/17/2005 14:40:00 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 14 36 303 305 138 58 108 0 -1.4 0.3 -0.4 -1.8 03/17/2005 14:50:00 1.1 0.3 1.9 0.4 1.5 0.3 2.3 1.1 0.4 0 0.4 0.4 303 0 302 305 254 0 255 0 -1.2 0.2 -0.6 -1.5 03/17/2005 15:00:00 1.5 1 3.8 0.4 1.7 1 4.2 0.4 0.4 0 0.4 0.4 215 64 147 305 206 36 169 0 -0.8 0.2 -0.1 -1.3 03/17/2005 15:10:00 0.9 0.7 3 0.4 1.1 0.8 3 0.4 0.4 0 0.4 0.4 107 32 135 305 149 16 174 0 -0.3 0.3 0.3 -0.6 03/17/2005 15:20:00 1.4 0.8 3.4 0.4 1.9 0.7 3.8 0.4 0.4 0 0.4 0.4 200 17 196 305 194 9 192 0 -0.9 0.4 0.6 -1.3 03/17/2005 15:30:00 1.3 0.7 3 0.4 1.6 0.8 3.4 0.4 0.4 0 0.4 0.4 106 94 181 305 147 45 181 0 -1.2 0.2 -0.6 -1.5 03/17/2005 15:40:00 1.3 0.4 2.6 0.4 1.6 0.4 2.6 1.1 0.4 0 0.4 0.4 289 24 309 305 221 47 249 0 -1.4 0.2 -0.6 -1.8 03/17/2005 15:50:00 0.8 0.4 1.9 0.4 1.3 0.4 2.3 0.7 0.4 0 0.4 0.4 311 4 319 305 77 2 80 0 -1.1 0.2 -0.4 -1.3 03/17/2005 16:00:00 1.5 0.4 2.3 0.4 1.8 0.3 2.6 1.1 0.4 0 0.4 0.4 309 13 313 305 31 82 76 0 -1.5 0.2 -1.1 -2 03/17/2005 16:10:00 1 0.8 2.6 0.4 1.4 0.6 2.6 0.4 0.4 0 0.4 0.4 325 26 303 305 107 56 247 0 -2.2 0.1 -1.5 -2.4 03/17/2005 16:20:00 0.6 0.4 2.3 0.4 0.9 0.6 2.3 0.4 0.4 0 0.4 0.4 295 82 208 305 146 49 206 0 -1.8 0.1 -1.1 -2 03/17/2005 16:30:00 0.7 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 243 45 266 305 208 35 244 0 -0.9 0.5 0.1 -1.8 03/17/2005 16:40:00 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 0.4 0 0.4 0.4 237 56 194 305 170 56 188 0 0.3 0.2 1 0.1 03/17/2005 16:50:00 1 0.4 1.9 0.4 1.2 0.4 2.3 0.4 0.4 0 0.4 0.4 218 26 188 305 202 13 191 0 -0.5 0.2 0.3 -1.1 03/17/2005 17:00:00 0.8 0.6 2.3 0.4 1.2 0.5 2.3 0.4 0.4 0 0.4 0.4 216 13 202 305 201 8 197 0 -0.8 0.2 0.1 -1.1 03/17/2005 17:10:00 0.8 0.6 2.3 0.4 1.1 0.7 2.6 0.4 0.4 0 0.4 0.4 103 72 47 305 140 36 114 0 -0.8 0.3 -0.4 -1.5 03/17/2005 17:20:00 1.6 0.8 3.4 0.4 1.8 0.8 3.4 0.4 0.4 0 0.4 0.4 77 22 66 305 121 11 116 0 -1.4 0.4 -0.4 -2 03/17/2005 17:30:00 1.1 1 3.8 0.4 1.1 1 4.2 0.4 0.4 0 0.4 0.4 122 58 62 305 144 32 113 0 -0.4 0.1 0.1 -0.8 03/17/2005 17:40:00 1.9 1.2 4.6 0.4 2.2 1.1 4.9 0.4 0.4 0 0.4 0.4 60 39 80 305 102 23 108 0 -1.5 0.3 -0.6 -1.8 03/17/2005 17:50:00 1.9 1.3 4.9 0.4 2.4 1.2 4.9 0.4 0.4 0 0.4 0.4 34 22 56 305 84 12 78 0 -2.2 0.4 -1.8 -2.9 03/17/2005 18:00:00 3.1 0.9 4.9 1.1 3.2 0.9 4.9 1.1 0.4 0 0.4 0.4 47 20 57 305 91 11 79 0 -2.8 0.1 -2 -3.1 03/17/2005 18:10:00 3.7 0.7 5.3 2.3 3.8 0.8 5.7 2.3 0.4 0 0.4 0.4 48 17 35 305 89 9 86 0 -3.1 0.3 -2 -3.3 03/17/2005 18:20:00 3 1 6.1 0.7 3.2 1 6.8 1.5 0.4 0 0.4 0.4 50 27 45 305 88 16 85 0 -3.3 0.2 -2.7 -3.8 03/17/2005 18:30:00 4.2 1.1 6.1 2.3 4.2 1.1 6.5 1.9 0.4 0 0.4 0.4 43 2 42 305 83 1 83 0 -3.7 0.2 -3.1 -3.8 03/17/2005 18:40:00 5 0.5 6.5 3.8 5.1 0.6 6.5 3 0.4 0 0.4 0.4 43 0 43 305 82 0 82 0 -3.6 0.2 -3.1 -3.8 03/17/2005 18:50:00 5.2 0.6 6.8 3.4 5.4 0.7 7.2 3.8 0.4 0 0.4 0.4 43 0 43 305 81 0 81 0 -3.8 0.1 -3.3 -4 03/17/2005 19:00:00 5.1 0.5 6.5 3.8 5.3 0.6 6.8 4.2 0.4 0 0.4 0.4 43 0 43 305 80 0 81 0 -4.2 0.1 -3.8 -4.5 03/17/2005 19:10:00 4.8 0.5 5.7 3.4 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 43 0 43 305 80 0 80 0 -4.4 0 -3.8 -4.7 03/17/2005 19:20:00 4.1 0.4 5.3 3.4 4.4 0.4 5.7 3.4 0.4 0 0.4 0.4 43 0 42 305 74 7 80 0 -4.6 0.1 -4 -4.7 03/17/2005 19:30:00 4.4 0.4 5.3 3.4 4.6 0.4 5.3 3.8 0.4 0 0.4 0.4 43 0 43 305 64 0 64 0 -4.9 0 -4.2 -5.1 03/17/2005 19:40:00 4.3 0.4 4.9 3.4 4.5 0.3 5.7 3.8 0.4 0 0.4 0.4 43 0 43 305 65 1 66 0 -4.9 0.1 -4.5 -5.1 03/17/2005 19:50:00 3.8 0.5 4.9 2.6 4 0.6 5.3 2.6 0.4 0 0.4 0.4 43 0 43 305 68 1 67 0 -5 0 -4.5 -5.1 03/17/2005 20:00:00 4 0.4 4.9 2.6 3.9 0.4 4.9 2.6 0.4 0 0.4 0.4 43 0 43 305 71 1 71 0 -4.9 0.1 -4.5 -4.9 03/17/2005 20:10:00 4.6 0.5 6.1 3.4 4.5 0.5 5.7 3 0.4 0 0.4 0.4 43 0 43 305 75 1 77 0 -4.9 0 -4.5 -5.1 03/17/2005 20:20:00 4.6 0.6 6.1 3.4 4.6 0.7 6.5 3.4 0.4 0 0.4 0.4 43 0 43 305 79 1 80 0 -4.9 0.1 -4.5 -5.1 03/17/2005 20:30:00 5.7 0.4 6.5 4.6 5.9 0.4 6.8 4.6 0.4 0 0.4 0.4 43 0 43 305 83 1 84 0 -4.9 0.1 -4.5 -5.1 03/17/2005 20:40:00 5.3 0.6 6.8 4.2 5.4 0.6 7.2 4.2 0.4 0 0.4 0.4 43 0 43 305 87 1 85 0 -4.6 0.1 -4 -4.7 03/17/2005 20:50:00 5.1 0.5 6.1 4.2 5.2 0.6 6.5 3.8 0.4 0 0.4 0.4 43 0 43 305 90 1 91 0 -4.3 0.1 -3.8 -4.5 03/17/2005 21:00:00 5.4 0.3 6.1 4.6 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 43 0 43 305 93 1 93 0 -4.2 0 -4 -4.5 03/17/2005 21:10:00 5.5 0.3 6.5 4.6 5.8 0.4 6.8 4.9 0.4 0 0.4 0.4 43 0 43 305 96 1 95 0 -4.1 0 -4 -4.2 03/17/2005 21:20:00 5.2 0.4 5.7 4.2 5.5 0.5 6.5 4.2 0.4 0 0.4 0.4 43 0 43 305 98 0 98 0 -4 0 -3.8 -4.2 03/17/2005 21:30:00 5.3 0.6 6.5 3.8 5.4 0.7 7.2 3.4 0.4 0 0.4 0.4 43 0 43 305 99 0 100 0 -3.9 0 -3.8 -4 03/17/2005 21:40:00 5.5 0.5 6.5 4.2 5.6 0.6 7.2 3.8 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.9 0 -3.3 -4 03/17/2005 21:50:00 5 0.4 5.7 3.8 5.1 0.5 6.1 3.4 0.4 0 0.4 0.4 43 0 43 305 101 0 101 0 -3.9 0 -3.8 -3.8 03/17/2005 22:00:00 4.6 0.7 6.5 3 4.7 0.8 6.5 3 0.4 0 0.4 0.4 43 0 43 305 101 0 101 0 -3.9 0 -3.3 -3.8 03/17/2005 22:10:00 5.4 0.5 6.5 3.8 5.6 0.6 6.8 3.8 0.4 0 0.4 0.4 43 0 43 305 101 0 101 0 -3.9 0 -3.3 -4 03/17/2005 22:20:00 6.2 0.5 7.2 4.6 6.4 0.6 7.2 4.6 0.4 0 0.4 0.4 43 0 43 305 101 0 101 0 -4 0 -3.8 -4 03/17/2005 22:30:00 5.9 0.4 6.8 4.9 6.2 0.4 7.2 5.3 0.4 0 0.4 0.4 43 0 44 305 102 0 101 0 -3.9 0 -3.8 -4 03/17/2005 22:40:00 6.5 0.4 7.2 5.3 6.7 0.5 8 5.3 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.9 0 -3.6 -4 03/17/2005 22:50:00 6.3 0.4 7.2 5.3 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.7 0 -3.6 -3.8 03/17/2005 23:00:00 6.3 0.4 6.8 4.9 6.6 0.4 7.2 5.3 0.4 0 0.4 0.4 44 0 44 305 102 0 103 0 -3.6 0 -3.3 -3.8 03/17/2005 23:10:00 6.6 0.3 7.6 5.3 6.8 0.4 8 5.7 0.4 0 0.4 0.4 44 0 44 305 103 0 103 0 -3.7 0 -3.6 -3.8 03/17/2005 23:20:00 6.3 0.4 6.8 4.9 6.5 0.4 7.2 5.3 0.4 0 0.4 0.4 44 0 44 305 103 0 103 0 -3.6 0 -3.3 -3.8 03/17/2005 23:30:00 6 0.4 7.2 4.9 6.3 0.4 7.2 5.3 0.4 0 0.4 0.4 44 0 44 305 103 0 103 0 -3.6 0 -3.3 -3.8 03/17/2005 23:40:00 5.5 0.5 6.5 4.2 5.7 0.5 6.8 4.2 0.4 0 0.4 0.4 44 0 44 305 103 0 103 0 -3.6 0 -3.3 -3.8 03/17/2005 23:50:00 5.2 0.4 6.1 4.2 5.5 0.4 6.5 4.6 0.4 0 0.4 0.4 44 0 44 305 103 0 103 0 -3.7 0 -3.6 -3.8 03/18/2005 00:00:00 4.9 0.4 6.1 3.8 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 44 0 44 305 103 0 103 0 -3.9 0 -3.3 -3.8 03/18/2005 00:10:00 5.1 0.5 6.5 3.4 5.2 0.6 6.5 3.8 0.4 0 0.4 0.4 44 0 44 305 103 0 103 0 -3.7 0 -3.6 -3.8 03/18/2005 00:20:00 5.6 0.7 7.2 4.2 5.7 0.6 7.2 4.2 0.4 0 0.4 0.4 44 0 44 305 103 0 103 0 -3.9 0 -3.6 -4 03/18/2005 00:30:00 6.1 0.5 6.8 4.6 6.1 0.5 6.8 4.9 0.4 0 0.4 0.4 44 0 44 305 102 0 103 0 -3.9 0 -3.8 -4 03/18/2005 00:40:00 5.8 0.4 6.8 4.9 6 0.4 7.2 4.9 0.4 0 0.4 0.4 44 0 44 305 102 0 103 0 -3.9 0 -3.8 -4 03/18/2005 00:50:00 5.7 0.4 6.8 4.6 5.9 0.4 6.8 4.6 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.9 0 -3.8 -4 03/18/2005 01:00:00 4.8 0.4 5.7 3.8 5 0.4 6.1 3.8 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.9 0 -3.8 -4 03/18/2005 01:10:00 4.6 0.3 5.3 3.8 4.8 0.4 5.7 3.4 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.9 0 -3.8 -4 03/18/2005 01:20:00 4.9 0.6 6.1 3.4 5.1 0.7 6.1 3.4 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.9 0 -3.8 -4 03/18/2005 01:30:00 5.1 0.5 6.1 3.8 5.3 0.5 6.5 4.2 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.9 0 -3.8 -4 03/18/2005 01:40:00 5.2 0.5 6.5 3.4 5.4 0.5 6.8 3.8 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.9 0 -3.8 -3.8 03/18/2005 01:50:00 5.1 0.6 6.5 3.8 5.2 0.6 6.8 3.8 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.8 0 -3.6 -4 03/18/2005 02:00:00 4.7 0.5 6.1 3.4 4.8 0.6 6.1 3 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.9 0 -3.8 -4 03/18/2005 02:10:00 5.3 0.5 6.1 4.2 5.3 0.5 6.5 4.2 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.9 0 -3.8 -4 03/18/2005 02:20:00 4.6 0.5 6.1 3.8 4.8 0.5 6.5 3.4 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.9 0 -3.8 -4 03/18/2005 02:30:00 5.3 0.5 6.8 3.8 5.4 0.5 6.8 3.8 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.9 0 -3.3 -4 03/18/2005 02:40:00 4.9 0.5 6.1 3.8 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.8 0 -3.6 -3.8 03/18/2005 02:50:00 5.1 0.8 6.5 3.4 5.2 0.8 6.8 3.4 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.7 0 -3.6 -3.8 03/18/2005 03:00:00 5.9 0.6 7.2 4.2 5.9 0.6 7.2 4.6 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.6 0 -3.3 -3.8 03/18/2005 03:10:00 5.8 0.5 6.8 4.6 5.8 0.5 7.2 4.6 0.4 0 0.4 0.4 44 0 44 305 102 0 102 0 -3.5 0 -3.1 -3.8 03/18/2005 03:20:00 5.7 0.5 7.2 4.6 5.6 0.5 7.2 4.2 0.4 0 0.4 0.4 44 0 44 305 103 0 103 0 -3.3 0 -3.3 -3.6 03/18/2005 03:30:00 6.4 0.5 7.6 4.9 6.3 0.5 7.6 4.9 0.4 0 0.4 0.4 43 0 43 305 103 0 103 0 -3.4 0 -3.3 -3.6 03/18/2005 03:40:00 6.3 0.6 7.6 4.9 6.3 0.6 7.6 4.9 0.4 0 0.4 0.4 43 0 43 305 103 0 103 0 -3.7 0.1 -3.3 -3.8 03/18/2005 03:50:00 6.8 0.5 8 5.3 6.8 0.5 8 5.3 0.4 0 0.4 0.4 43 0 43 305 102 0 102 0 -3.7 0 -3.6 -3.8 03/18/2005 04:00:00 6.8 0.6 8 4.9 6.8 0.6 8 4.9 0.4 0 0.4 0.4 43 0 43 305 102 0 102 0 -3.7 0 -3.8 -3.8 03/18/2005 04:10:00 6.6 0.6 8.4 4.9 6.5 0.7 8 4.9 0.4 0 0.4 0.4 43 0 43 305 102 0 102 0 -3.9 0 -3.8 -3.8 03/18/2005 04:20:00 6.8 0.5 8 5.7 6.9 0.5 8 5.7 0.4 0 0.4 0.4 43 0 43 305 101 0 101 0 -3.9 0 -3.8 -4 03/18/2005 04:30:00 6.6 0.6 7.6 4.9 6.6 0.6 8 4.9 0.4 0 0.4 0.4 43 0 43 305 101 0 101 0 -3.9 0 -3.6 -4 03/18/2005 04:40:00 6.4 0.6 7.6 4.6 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 43 0 43 305 101 0 101 0 -3.9 0 -3.8 -4 03/18/2005 04:50:00 6.2 0.7 7.6 4.6 6.2 0.6 7.6 4.2 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.9 0 -3.8 -4 03/18/2005 05:00:00 6.2 0.7 7.6 4.2 6.1 0.7 8 4.6 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.9 0 -3.8 -4 03/18/2005 05:10:00 6.1 0.5 7.2 4.6 6.1 0.5 7.6 4.6 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.9 0 -3.3 -4 03/18/2005 05:20:00 7.5 0.5 8.4 6.1 7.4 0.6 8.8 6.1 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.9 0 -3.8 -4 03/18/2005 05:30:00 7 0.8 8.8 5.3 7 0.7 9.1 5.3 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.9 0 -3.8 -4 03/18/2005 05:40:00 7.5 0.7 9.1 5.7 7.5 0.6 9.1 5.7 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.8 0 -3.6 -3.8 03/18/2005 05:50:00 7.5 0.7 9.1 5.7 7.5 0.6 9.5 6.1 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.7 0 -3.6 -3.8 03/18/2005 06:00:00 7.8 0.5 9.1 6.1 7.8 0.5 9.1 6.1 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.7 0 -3.6 -3.8 03/18/2005 06:10:00 7.6 0.8 9.5 5.7 7.5 0.8 9.1 5.3 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.7 0 -3.6 -3.8 03/18/2005 06:20:00 7.8 0.6 9.5 6.5 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.8 0 -3.6 -3.8 03/18/2005 06:30:00 6.3 0.7 8 4.6 6.4 0.7 8.4 4.6 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.7 0 -3.6 -3.8 03/18/2005 06:40:00 6.6 0.6 8 4.9 6.7 0.7 8 4.6 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.6 0 -3.3 -3.8 03/18/2005 06:50:00 6.6 0.6 8 4.9 6.4 0.6 8 4.9 0.4 0 0.4 0.4 43 0 43 305 100 0 100 0 -3.7 0 -3.6 -3.8 03/18/2005 07:00:00 7.1 0.8 8.8 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 43 0 43 305 99 0 99 0 -3.9 0 -3.8 -4 03/18/2005 07:10:00 6.9 0.8 8.4 5.3 6.9 0.8 9.1 4.6 0.4 0 0.4 0.4 43 0 43 305 99 0 99 0 -4.1 0 -3.8 -4.2 03/18/2005 07:20:00 6.6 0.6 8 4.9 6.6 0.6 8 4.9 0.4 0 0.4 0.4 43 0 43 305 98 0 99 0 -4.2 0 -4 -4.5 03/18/2005 07:30:00 7.2 0.7 8.4 4.9 7.1 0.7 9.1 5.3 0.4 0 0.4 0.4 43 0 42 305 97 0 97 0 -4.4 0 -4.2 -4.5 03/18/2005 07:40:00 7.7 0.8 9.5 5.7 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 43 0 42 305 97 0 96 0 -4.4 0 -4 -4.5 03/18/2005 07:50:00 7.7 0.7 9.1 5.3 7.4 0.6 9.1 5.7 0.4 0 0.4 0.4 43 0 42 305 96 0 96 0 -4.4 0 -4.5 -4.5 03/18/2005 08:00:00 7.6 0.7 8.8 6.1 7.4 0.7 9.1 5.3 0.4 0 0.4 0.4 42 0 42 305 96 0 96 0 -4.4 0 -4.2 -4.5 03/18/2005 08:10:00 7.6 0.7 8.8 5.7 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 42 0 42 305 96 0 96 0 -4.4 0 -4.5 -4.7 03/18/2005 08:20:00 7.8 0.6 8.8 6.1 7.8 0.7 9.1 6.1 0.4 0 0.4 0.4 42 0 42 305 95 0 95 0 -4.6 0 -4.5 -4.7 03/18/2005 08:30:00 7.5 0.7 8.8 5.7 7.2 0.7 9.1 5.7 0.4 0 0.4 0.4 42 0 42 305 95 0 95 0 -4.6 0 -4.5 -4.7 03/18/2005 08:40:00 6.9 0.7 8.4 4.9 6.8 0.7 8.8 4.9 0.4 0 0.4 0.4 42 0 42 305 95 0 95 0 -4.6 0 -4.5 -4.7 03/18/2005 08:50:00 7.1 0.6 8.4 5.3 6.9 0.7 8.8 4.9 0.4 0 0.4 0.4 42 0 42 305 95 0 95 0 -4.7 0 -4.5 -4.7 03/18/2005 09:00:00 6.4 0.6 7.6 4.6 6.5 0.6 8 4.6 0.4 0 0.4 0.4 42 0 42 305 94 0 94 0 -4.7 0 -4.5 -4.7 03/18/2005 09:10:00 6.4 0.6 7.6 4.6 6.4 0.7 7.6 4.6 0.4 0 0.4 0.4 42 0 42 305 94 0 94 0 -4.7 0 -4.5 -4.9 03/18/2005 09:20:00 6.6 0.6 8 4.6 6.5 0.6 8 4.9 0.4 0 0.4 0.4 42 0 42 305 94 0 94 0 -4.9 0 -4.7 -4.9 03/18/2005 09:30:00 6 0.6 7.2 4.6 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 42 0 42 305 93 0 93 0 -4.9 0 -4.7 -4.9 03/18/2005 09:40:00 6.2 0.5 7.2 4.6 6.3 0.6 8 4.9 0.4 0 0.4 0.4 42 0 42 305 93 0 93 0 -4.8 0 -4.7 -4.9 03/18/2005 09:50:00 6 0.5 7.2 4.6 6.2 0.6 7.6 4.9 0.4 0 0.4 0.4 42 0 42 305 93 0 93 0 -4.7 0 -4.5 -4.7 03/18/2005 10:00:00 6.1 0.6 7.6 4.6 6.1 0.6 8 4.6 0.4 0 0.4 0.4 42 0 42 305 93 0 93 0 -4.6 0 -4.5 -4.7 03/18/2005 10:10:00 6.1 0.7 7.6 4.2 6.2 0.7 8 4.2 0.4 0 0.4 0.4 42 0 42 305 94 0 93 0 -4.4 0 -4.2 -4.7 03/18/2005 10:20:00 5.9 0.6 7.2 4.6 6.1 0.6 7.2 4.6 0.4 0 0.4 0.4 42 0 42 305 94 0 94 0 -4.3 0 -4 -4.5 03/18/2005 10:30:00 6.2 0.6 7.6 4.9 6.3 0.6 7.6 4.9 0.4 0 0.4 0.4 42 0 42 305 94 0 94 0 -4.2 0 -4 -4.5 03/18/2005 10:40:00 6.4 0.6 7.6 4.9 6.6 0.6 8 5.3 0.4 0 0.4 0.4 42 0 42 305 95 0 95 0 -4 0 -3.8 -4 03/18/2005 10:50:00 6.9 0.7 8.8 4.9 7 0.7 8.8 4.9 0.4 0 0.4 0.4 42 0 42 305 95 0 95 0 -3.9 0 -3.8 -4 03/18/2005 11:00:00 7.3 0.5 8.4 5.3 7.4 0.5 8.8 6.1 0.4 0 0.4 0.4 42 0 42 305 95 0 95 0 -3.7 0 -3.6 -3.8 03/18/2005 11:10:00 7.7 0.6 9.1 5.7 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 42 0 42 305 95 0 95 0 -3.6 0 -3.3 -3.8 03/18/2005 11:20:00 7.6 0.5 8.8 6.1 7.5 0.6 8.8 6.1 0.4 0 0.4 0.4 42 0 42 305 95 0 95 0 -3.5 0 -3.1 -3.6 03/18/2005 11:30:00 7.8 0.7 9.5 6.1 7.8 0.7 9.5 6.1 0.4 0 0.4 0.4 42 0 42 305 94 0 94 0 -3.5 0 -3.3 -3.6 03/18/2005 11:40:00 8 0.8 9.5 5.7 8.1 0.8 9.5 5.7 0.4 0 0.4 0.4 43 0 42 305 93 0 93 0 -3.5 0 -3.1 -3.8 03/18/2005 11:50:00 7.6 0.6 9.1 6.1 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 43 0 42 305 92 0 92 0 -3.4 0 -3.3 -3.6 03/18/2005 12:00:00 7.1 0.6 8.4 5.7 7.3 0.6 8.8 5.3 0.4 0 0.4 0.4 43 0 42 305 91 0 91 0 -3.3 0 -3.3 -3.6 03/18/2005 12:10:00 7.2 0.5 8.8 5.7 7.4 0.6 9.1 5.7 0.4 0 0.4 0.4 43 0 42 305 90 0 90 0 -3.3 0 -3.1 -3.6 03/18/2005 12:20:00 7.1 0.6 8.4 5.3 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 43 0 42 305 89 0 89 0 -3.2 0 -3.1 -3.3 03/18/2005 12:30:00 6.9 0.5 8.4 5.7 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 43 0 43 305 88 0 89 0 -3 0 -2.9 -3.3 03/18/2005 12:40:00 7.6 0.5 9.1 6.5 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 43 0 43 305 88 0 88 0 -3 0 -2.4 -3.1 03/18/2005 12:50:00 7.6 0.6 8.8 6.1 7.9 0.6 9.9 6.1 0.4 0 0.4 0.4 43 0 43 305 87 0 87 0 -3 0 -2.7 -3.1 03/18/2005 13:00:00 8 0.6 9.5 6.1 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 43 0 43 305 86 0 86 0 -3 0 -2.9 -3.1 03/18/2005 13:10:00 8 0.7 9.9 6.1 8.6 0.7 10.7 6.8 0.4 0 0.4 0.4 43 0 43 305 85 0 85 0 -3.1 0 -2.9 -3.1 03/18/2005 13:20:00 7.8 0.7 9.9 6.1 8.1 0.7 10.3 6.5 0.4 0 0.4 0.4 43 0 43 305 84 0 84 0 -3 0 -2.9 -3.1 03/18/2005 13:30:00 8.3 0.7 9.9 6.5 8.7 0.8 11.1 6.5 0.4 0 0.4 0.4 43 0 43 305 83 0 84 0 -3 0 -2.9 -3.1 03/18/2005 13:40:00 7.9 0.8 9.9 6.1 8.4 0.9 10.3 6.5 0.4 0 0.4 0.4 43 0 43 305 82 0 82 0 -3 0 -2.9 -3.1 03/18/2005 13:50:00 7.4 0.7 9.1 5.7 7.8 0.8 9.9 6.1 0.4 0 0.4 0.4 43 0 42 305 81 0 82 0 -3 0 -2.9 -3.1 03/18/2005 14:00:00 7.3 0.7 9.1 4.9 7.8 0.8 9.5 5.7 0.4 0 0.4 0.4 43 0 43 305 79 1 79 0 -3.1 0 -2.9 -3.3 03/18/2005 14:10:00 8.2 0.8 9.5 6.1 8.8 1 10.7 6.5 0.4 0 0.4 0.4 43 0 43 305 77 0 77 0 -3.2 0 -2.9 -3.3 03/18/2005 14:20:00 8.6 0.8 10.3 6.8 9.3 0.9 11.5 6.8 0.4 0 0.4 0.4 42 2 42 305 76 0 74 0 -3.1 0 -2.7 -3.3 03/18/2005 14:30:00 8.8 0.7 10.3 7.2 9.4 0.9 11.5 6.8 0.4 0 0.4 0.4 39 4 36 305 74 1 74 0 -3.2 0 -3.1 -3.3 03/18/2005 14:40:00 8.9 1 10.7 6.1 9.8 1.1 12.2 7.2 0.4 0 0.4 0.4 38 4 37 305 72 0 72 0 -3.2 0 -3.1 -3.3 03/18/2005 14:50:00 8.7 0.8 10.3 6.5 9.6 0.9 12.2 6.8 0.4 0 0.4 0.4 40 5 34 305 70 1 71 0 -3.2 0 -3.1 -3.3 03/18/2005 15:00:00 7.8 0.9 9.9 5.7 8.7 1 11.5 6.5 0.4 0 0.4 0.4 41 5 37 305 69 0 69 0 -3.1 0 -2.9 -3.3 03/18/2005 15:10:00 7.8 1.2 10.3 5.3 8.6 1.3 11.5 5.7 0.4 0 0.4 0.4 40 5 40 305 68 0 69 0 -3.1 0 -2.9 -3.3 03/18/2005 15:20:00 8 0.8 9.5 5.3 8.7 0.9 10.7 6.8 0.4 0 0.4 0.4 41 5 41 305 67 0 68 0 -3.1 0 -2.9 -3.1 03/18/2005 15:30:00 8.6 0.9 10.7 5.3 9.3 1 11.5 6.5 0.4 0 0.4 0.4 40 5 37 305 65 1 66 0 -3.1 0 -2.9 -3.1 03/18/2005 15:40:00 9.4 0.9 11.8 7.2 10 1 12.6 7.6 0.4 0 0.4 0.4 42 5 44 305 62 1 63 0 -3.1 0 -3.1 -3.3 03/18/2005 15:50:00 9.9 1.1 13 6.8 10.6 1.2 13.7 7.6 0.4 0 0.4 0.4 42 6 46 305 60 1 59 0 -3.2 0 -2.9 -3.3 03/18/2005 16:00:00 10.4 1.2 13.3 7.2 11 1.3 14.5 7.6 0.4 0 0.4 0.4 41 5 40 305 58 1 59 0 -3.2 0 -2.7 -3.3 03/18/2005 16:10:00 10 1.2 13 7.2 10.5 1.2 13.7 7.6 0.4 0 0.4 0.4 40 5 35 305 57 0 57 0 -3.3 0 -2.7 -3.3 03/18/2005 16:20:00 9.5 1.1 11.8 6.8 10 1.2 12.6 7.2 0.4 0 0.4 0.4 42 6 30 305 57 0 57 0 -3.3 0 -2.7 -3.3 03/18/2005 16:30:00 10.1 1.1 13 7.6 10.7 1.1 13.3 8.4 0.4 0 0.4 0.4 42 5 32 305 56 1 55 0 -3.3 0 -3.1 -3.3 03/18/2005 16:40:00 10.5 1.1 13.3 7.6 10.8 1.1 13.3 8 0.4 0 0.4 0.4 40 5 42 305 53 0 53 0 -3.3 0 -2.7 -3.3 03/18/2005 16:50:00 10.6 1 13 8 11 1 13.7 8.4 0.4 0 0.4 0.4 40 5 41 305 52 0 53 0 -3.3 0 -3.1 -3.3 03/18/2005 17:00:00 11 1.2 14.1 8.4 11.2 1.3 14.9 8.8 0.4 0 0.4 0.4 41 5 40 305 51 0 51 0 -3.3 0 -3.1 -3.3 03/18/2005 17:10:00 11.4 1.6 14.5 7.6 11.6 1.6 15.3 8 0.4 0 0.4 0.4 41 5 49 305 49 1 49 0 -3.3 0 -3.3 -3.3 03/18/2005 17:20:00 11.4 1.6 15.3 7.6 11.5 1.7 16.1 8 0.4 0 0.4 0.4 41 5 39 305 48 0 48 0 -3.3 0 -3.1 -3.3 03/18/2005 17:30:00 11.8 1 14.1 9.1 11.8 1 14.5 9.5 0.4 0 0.4 0.4 40 5 48 305 48 0 49 0 -3.3 0 -3.1 -3.3 03/18/2005 17:40:00 11.7 1.3 14.9 8.8 11.7 1.3 14.9 9.1 0.4 0 0.4 0.4 41 5 39 305 48 0 48 0 -3.3 0 -3.1 -3.3 03/18/2005 17:50:00 12.1 1 14.1 9.1 12.1 1 14.5 9.5 0.4 0 0.4 0.4 38 4 41 305 47 0 48 0 -3.3 0 -2.9 -3.3 03/18/2005 18:00:00 12.3 1.2 14.9 9.5 12.2 1.2 15.3 8.8 0.4 0 0.4 0.4 38 5 32 305 47 0 47 0 -3.3 0 -3.1 -3.3 03/18/2005 18:10:00 11.3 1.1 13.3 8.4 11.3 1.2 13.7 8.4 0.4 0 0.4 0.4 40 5 41 305 47 0 47 0 -3.2 0 -2.7 -3.3 03/18/2005 18:20:00 10.6 1.2 13 7.6 10.6 1.2 13.7 7.2 0.4 0 0.4 0.4 45 6 42 305 48 0 48 0 -3.1 0 -2.7 -3.3 03/18/2005 18:30:00 9.8 1.3 13.7 6.8 9.6 1.2 14.1 7.6 0.4 0 0.4 0.4 45 5 53 305 48 0 48 0 -3.1 0 -3.1 -3.3 03/18/2005 18:40:00 11.6 1.2 14.1 8.4 11.3 1.2 13.7 8 0.4 0 0.4 0.4 45 6 41 305 47 0 48 0 -3.2 0 -3.1 -3.3 03/18/2005 18:50:00 11 1.2 13.3 8 10.8 1.2 14.1 7.6 0.4 0 0.4 0.4 49 6 45 305 47 0 47 0 -3.1 0 -3.1 -3.3 03/18/2005 19:00:00 10.6 1 13.3 8 10.5 1.1 13.3 7.2 0.4 0 0.4 0.4 49 5 49 305 48 0 47 0 -3.1 0 -2.9 -3.3 03/18/2005 19:10:00 12 1.3 15.6 8.8 11.8 1.4 15.3 9.1 0.4 0 0.4 0.4 50 5 56 305 48 0 48 0 -3.1 0 -3.1 -3.1 03/18/2005 19:20:00 12.3 1.3 15.6 9.1 12.1 1.3 15.3 8.8 0.4 0 0.4 0.4 50 6 47 305 47 0 46 0 -3.2 0 -3.1 -3.3 03/18/2005 19:30:00 11.4 1 14.1 9.1 11.2 1 14.1 8.8 0.4 0 0.4 0.4 54 5 46 305 47 0 47 0 -3.2 0 -3.1 -3.3 03/18/2005 19:40:00 13.2 1.3 16.4 9.5 12.8 1.3 16.4 9.1 0.4 0 0.4 0.4 55 5 65 305 47 0 47 0 -3.2 0 -3.1 -3.3 03/18/2005 19:50:00 12.5 1.3 15.6 9.5 12.1 1.3 14.9 9.1 0.4 0 0.4 0.4 52 5 56 305 47 0 47 0 -3.2 0 -3.1 -3.3 03/18/2005 20:00:00 13.7 1.2 16.4 10.7 13.4 1.2 16.1 10.7 0.4 0 0.4 0.4 50 4 53 305 46 0 46 0 -3.2 0 -3.1 -3.3 03/18/2005 20:10:00 11.7 1 14.1 9.1 11.5 1 13.7 9.1 0.4 0 0.4 0.4 51 5 57 305 45 0 45 0 -3.2 0 -3.1 -3.3 03/18/2005 20:20:00 11.6 1.5 15.3 8 11.2 1.5 15.6 8.4 0.4 0 0.4 0.4 53 5 51 305 45 0 45 0 -3.2 0 -3.1 -3.3 03/18/2005 20:30:00 11.6 1.5 15.3 7.6 11.3 1.5 14.5 7.2 0.4 0 0.4 0.4 58 6 54 305 44 0 44 0 -3.3 0 -3.1 -3.3 03/18/2005 20:40:00 11.8 1.4 14.9 8.4 11.5 1.4 14.9 7.6 0.4 0 0.4 0.4 58 6 57 305 43 0 43 0 -3.3 0 -3.1 -3.3 03/18/2005 20:50:00 10 1.5 13.3 6.5 9.8 1.5 13 6.5 0.4 0 0.4 0.4 57 6 63 305 42 0 42 0 -3.3 0 -3.1 -3.3 03/18/2005 21:00:00 9.6 1.3 13.3 6.5 9.5 1.3 13.3 6.8 0.4 0 0.4 0.4 60 8 57 305 42 0 42 0 -3.3 0 -3.1 -3.3 03/18/2005 21:10:00 10.5 1 13.3 8.4 10.4 1.1 13 7.2 0.4 0 0.4 0.4 61 7 50 305 42 0 41 0 -3.3 0 -3.3 -3.3 03/18/2005 21:20:00 12 1.2 16.1 8.8 11.8 1.3 14.9 9.1 0.4 0 0.4 0.4 57 6 42 305 41 0 40 0 -3.3 0 -3.3 -3.3 03/18/2005 21:30:00 12.7 1 15.3 10.3 12.3 1 15.3 9.5 0.4 0 0.4 0.4 50 5 48 305 40 0 40 0 -3.3 0 -3.3 -3.3 03/18/2005 21:40:00 11.7 1.2 14.5 9.1 11.4 1.2 14.5 8.8 0.4 0 0.4 0.4 54 6 62 305 41 0 40 0 -3.3 0 -3.1 -3.3 03/18/2005 21:50:00 9.8 1.3 13.7 6.5 9.7 1.2 14.1 6.5 0.4 0 0.4 0.4 59 6 54 305 41 0 41 0 -3.3 0 -3.1 -3.3 03/18/2005 22:00:00 10.7 1.2 13.7 7.2 10.6 1.2 13.7 7.2 0.4 0 0.4 0.4 61 5 58 305 41 0 41 0 -3.3 0 -2.9 -3.3 03/18/2005 22:10:00 11.9 1 14.5 8.8 11.6 1.2 14.5 8.4 0.4 0 0.4 0.4 61 6 57 305 41 0 40 0 -3.3 0 -3.1 -3.3 03/18/2005 22:20:00 11.6 1.2 15.3 9.1 11.4 1.2 15.3 9.1 0.4 0 0.4 0.4 62 6 62 305 40 0 40 0 -3.3 0 -3.1 -3.3 03/18/2005 22:30:00 12.5 1 15.3 10.3 12.3 1.1 15.3 9.9 0.4 0 0.4 0.4 62 5 64 305 39 1 37 0 -3.3 0 -3.1 -3.3 03/18/2005 22:40:00 11.6 1.4 14.9 8 11.3 1.3 14.5 8 0.4 0 0.4 0.4 62 5 59 305 39 0 39 0 -3.3 0 -3.1 -3.3 03/18/2005 22:50:00 11.4 1.1 14.1 8.8 11.1 1.1 14.1 8.4 0.4 0 0.4 0.4 62 6 55 305 39 0 39 0 -3.3 0 -3.1 -3.3 03/18/2005 23:00:00 12.2 1 15.6 9.9 12 1 15.3 9.5 0.4 0 0.4 0.4 62 5 61 305 39 0 39 0 -3.3 0 -3.1 -3.3 03/18/2005 23:10:00 12.5 1.1 15.6 9.5 12.3 1.2 15.3 8.8 0.4 0 0.4 0.4 61 5 64 305 39 0 39 0 -3.2 0 -3.1 -3.3 03/18/2005 23:20:00 11.7 1.1 14.5 9.1 11.4 1.1 14.1 8.8 0.4 0 0.4 0.4 58 5 48 305 39 0 39 0 -3.2 0 -3.1 -3.3 03/18/2005 23:30:00 11.4 1.1 13.7 9.1 11.2 1.2 13.7 8.4 0.4 0 0.4 0.4 59 5 65 305 40 0 40 0 -3.2 0 -3.1 -3.3 03/18/2005 23:40:00 10.7 1.3 14.1 7.6 10.6 1.3 14.1 7.6 0.4 0 0.4 0.4 61 5 58 305 40 0 40 0 -3.2 0 -3.1 -3.3 03/18/2005 23:50:00 9.9 1.2 13.3 7.2 9.7 1.2 12.6 7.2 0.4 0 0.4 0.4 60 5 57 305 40 0 40 0 -3.2 0 -3.1 -3.3 03/19/2005 00:00:00 9.4 1.1 12.2 7.2 9.4 1.1 11.8 6.8 0.4 0 0.4 0.4 57 5 63 305 40 0 41 0 -3.2 0 -2.7 -3.3 03/19/2005 00:10:00 10 1.1 13 7.2 9.9 1.1 13.3 7.2 0.4 0 0.4 0.4 54 5 51 305 41 0 41 0 -3.3 0 -3.1 -3.3 03/19/2005 00:20:00 9.8 0.9 11.8 8 9.7 0.9 11.8 7.6 0.4 0 0.4 0.4 54 5 56 305 41 0 40 0 -3.3 0 -3.1 -3.3 03/19/2005 00:30:00 10.1 0.9 12.2 8 9.9 1 12.2 7.6 0.4 0 0.4 0.4 53 5 57 305 41 0 41 0 -3.3 0 -2.7 -3.3 03/19/2005 00:40:00 10.7 1 13.3 8.4 10.5 1 13 8 0.4 0 0.4 0.4 54 5 52 305 41 0 41 0 -3.3 0 -3.1 -3.3 03/19/2005 00:50:00 10 1 13 8 9.9 1 12.6 7.6 0.4 0 0.4 0.4 57 5 52 305 41 0 40 0 -3.3 0 -3.1 -3.3 03/19/2005 01:00:00 10.9 1.1 13.7 8 10.7 1.2 13.7 8 0.4 0 0.4 0.4 56 5 58 305 41 0 40 0 -3.2 0 -2.9 -3.3 03/19/2005 01:10:00 11.9 0.9 13.7 8.8 11.7 0.9 13.7 8.8 0.4 0 0.4 0.4 57 5 54 305 40 0 40 0 -3.2 0 -3.1 -3.3 03/19/2005 01:20:00 11.2 1.1 14.1 8.4 11 1.1 13.7 7.6 0.4 0 0.4 0.4 57 5 57 305 40 0 40 0 -3.2 0 -3.1 -3.3 03/19/2005 01:30:00 10.6 1 13.3 8.8 10.4 1 13 8.4 0.4 0 0.4 0.4 59 5 58 305 40 0 40 0 -3.2 0 -3.1 -3.3 03/19/2005 01:40:00 10.4 1.1 13 8 10.2 1 13.3 8 0.4 0 0.4 0.4 61 5 54 305 40 0 40 0 -3.3 0 -3.1 -3.3 03/19/2005 01:50:00 11 1.2 13.7 8.4 10.7 1.2 13.7 8.4 0.4 0 0.4 0.4 58 5 56 305 40 0 40 0 -3.3 0 -3.1 -3.3 03/19/2005 02:00:00 11.4 0.9 13.7 8.8 11.1 1 13.7 8.8 0.4 0 0.4 0.4 59 5 62 305 40 0 40 0 -3.3 0 -3.1 -3.3 03/19/2005 02:10:00 11.3 1.2 14.5 8.4 11.1 1.2 14.1 7.6 0.4 0 0.4 0.4 58 5 55 305 39 0 39 0 -3.3 0 -3.1 -3.3 03/19/2005 02:20:00 12 1.1 14.5 9.1 11.7 1.1 14.5 8.8 0.4 0 0.4 0.4 59 5 56 305 39 0 39 0 -3.3 0 -3.1 -3.3 03/19/2005 02:30:00 11.6 1 14.1 8.8 11.3 1 14.1 9.1 0.4 0 0.4 0.4 62 4 60 305 39 0 39 0 -3.3 0 -3.1 -3.3 03/19/2005 02:40:00 11.3 0.9 13.7 9.1 11 0.9 14.1 9.1 0.4 0 0.4 0.4 63 5 64 305 39 0 39 0 -3.3 0 -3.1 -3.3 03/19/2005 02:50:00 11.4 0.8 13.7 9.1 11.3 0.8 13.7 9.5 0.4 0 0.4 0.4 62 4 62 305 38 0 38 0 -3.3 0 -3.1 -3.3 03/19/2005 03:00:00 11.3 0.8 13 9.5 11.2 0.7 13.3 9.5 0.4 0 0.4 0.4 62 4 60 305 38 0 38 0 -3.3 0 -3.1 -3.3 03/19/2005 03:10:00 11.7 0.9 13.7 9.5 11.5 0.9 13.3 8.8 0.4 0 0.4 0.4 62 4 59 305 38 0 38 0 -3.3 0 -2.9 -3.3 03/19/2005 03:20:00 11.5 0.8 13.3 9.1 11.3 0.9 13.3 8.8 0.4 0 0.4 0.4 60 4 61 305 39 0 39 0 -3.3 0 -3.1 -3.3 03/19/2005 03:30:00 11 0.9 13.7 9.1 10.9 0.9 13.7 8.8 0.4 0 0.4 0.4 62 4 63 305 39 0 39 0 -3.3 0 -3.1 -3.3 03/19/2005 03:40:00 9.6 0.6 11.5 8 9.5 0.6 11.1 8 0.4 0 0.4 0.4 62 4 62 305 39 0 39 0 -3.3 0 -3.1 -3.3 03/19/2005 03:50:00 9.6 0.6 11.5 8 9.6 0.6 11.5 8 0.4 0 0.4 0.4 63 3 58 305 40 0 40 0 -3.2 0 -3.1 -3.3 03/19/2005 04:00:00 11 0.6 12.2 9.1 10.9 0.6 12.6 8.8 0.4 0 0.4 0.4 65 3 63 305 40 0 40 0 -3.1 0 -2.7 -3.3 03/19/2005 04:10:00 11.6 0.7 14.1 9.9 11.5 0.8 14.1 9.5 0.4 0 0.4 0.4 67 3 68 305 39 0 39 0 -3.1 0 -2.9 -3.1 03/19/2005 04:20:00 12.8 0.6 14.1 11.5 12.6 0.6 14.5 10.7 0.4 0 0.4 0.4 70 3 72 305 38 0 39 0 -3 0 -2.7 -3.1 03/19/2005 04:30:00 13 0.7 14.5 11.5 12.9 0.7 14.9 10.7 0.4 0 0.4 0.4 71 3 74 305 38 0 38 0 -3 0 -2.7 -3.1 03/19/2005 04:40:00 13.1 0.6 14.9 11.5 12.8 0.7 14.9 10.7 0.4 0 0.4 0.4 71 3 67 305 37 0 37 0 -3 0 -2.7 -4 03/19/2005 04:50:00 12.2 0.6 14.1 9.9 12.1 0.6 14.1 10.3 0.4 0 0.4 0.4 72 3 76 305 36 0 36 0 -2.8 0 -2.7 -3.1 03/19/2005 05:00:00 12.2 0.6 13.7 10.3 12 0.7 13.7 10.3 0.4 0 0.4 0.4 74 4 70 305 36 0 36 0 -2.8 0 -2.7 -2.9 03/19/2005 05:10:00 12.9 0.7 14.9 11.1 12.7 0.8 14.5 10.7 0.4 0 0.4 0.4 74 3 68 305 35 0 35 0 -2.8 0 -2.7 -2.9 03/19/2005 05:20:00 12.8 1 15.3 10.7 12.6 1 15.3 9.9 0.4 0 0.4 0.4 75 4 73 305 35 0 35 0 -2.8 0 -2.7 -2.9 03/19/2005 05:30:00 12 0.8 14.9 9.5 11.8 0.9 14.5 9.5 0.4 0 0.4 0.4 76 5 87 305 35 0 34 0 -2.8 0 -2.7 -3.1 03/19/2005 05:40:00 11.6 0.7 13.3 9.5 11.3 0.8 13.7 9.5 0.4 0 0.4 0.4 76 4 71 305 35 0 35 0 -2.8 0 -2.4 -3.1 03/19/2005 05:50:00 11.4 0.7 13.3 9.1 11.2 0.8 13.3 8.8 0.4 0 0.4 0.4 76 4 77 305 34 0 34 0 -2.8 0 -2.7 -3.1 03/19/2005 06:00:00 11.2 0.6 12.6 9.5 11 0.6 12.6 8.4 0.4 0 0.4 0.4 76 4 81 305 34 0 34 0 -2.9 0 -2.4 -3.1 03/19/2005 06:10:00 10.6 0.7 12.2 8.8 10.4 0.8 12.2 8.4 0.4 0 0.4 0.4 74 4 76 305 34 0 34 0 -2.9 0 -2.7 -3.1 03/19/2005 06:20:00 10.6 0.6 13 8.8 10.5 0.7 12.6 8.4 0.4 0 0.4 0.4 73 4 72 305 33 0 33 0 -3 0 -2.9 -3.1 03/19/2005 06:30:00 10.5 0.7 12.2 8.8 10.4 0.7 12.2 8 0.4 0 0.4 0.4 73 4 73 305 31 1 31 0 -3.1 0 -2.9 -3.1 03/19/2005 06:40:00 10.2 0.7 12.2 8.4 10.1 0.7 11.8 7.6 0.4 0 0.4 0.4 72 4 77 305 31 0 31 0 -3.1 0 -3.1 -3.3 03/19/2005 06:50:00 10.4 0.7 12.2 8.8 10.4 0.7 12.6 8.8 0.4 0 0.4 0.4 71 3 69 305 30 0 30 0 -3 0 -2.9 -3.1 03/19/2005 07:00:00 10.2 0.6 11.8 8.8 10.1 0.6 11.8 8.4 0.4 0 0.4 0.4 70 4 74 305 30 0 30 0 -3 0 -2.9 -3.1 03/19/2005 07:10:00 10.1 0.6 11.8 8 10.1 0.7 11.8 8.4 0.4 0 0.4 0.4 69 4 69 305 30 0 29 0 -3 0 -2.9 -3.1 03/19/2005 07:20:00 10.2 0.8 11.8 8 10 0.8 11.8 8 0.4 0 0.4 0.4 70 4 78 305 29 0 29 0 -3 0 -2.9 -3.1 03/19/2005 07:30:00 10.2 0.9 12.2 8 10.1 1 12.2 8 0.4 0 0.4 0.4 68 5 70 305 29 0 29 0 -2.9 0 -2.7 -3.1 03/19/2005 07:40:00 9.7 0.7 11.5 8 9.6 0.8 11.1 7.6 0.4 0 0.4 0.4 67 4 77 305 29 0 29 0 -3 0 -2.7 -3.1 03/19/2005 07:50:00 9.7 0.7 11.8 8 9.6 0.8 12.2 7.6 0.4 0 0.4 0.4 66 4 61 305 30 0 29 0 -3 0 -2.9 -3.1 03/19/2005 08:00:00 9.1 0.8 11.1 6.8 9.1 0.7 11.1 6.8 0.4 0 0.4 0.4 67 4 71 305 30 0 30 0 -3 0 -2.9 -3.1 03/19/2005 08:10:00 9.4 0.7 11.1 7.2 9.4 0.8 11.1 6.8 0.4 0 0.4 0.4 65 5 62 305 30 0 30 0 -3 0 -2.9 -3.1 03/19/2005 08:20:00 9.9 0.6 11.5 8 9.8 0.6 11.1 8 0.4 0 0.4 0.4 68 3 70 305 30 0 30 0 -3 0 -2.9 -3.1 03/19/2005 08:30:00 10 0.6 11.5 8.4 9.9 0.6 11.5 8 0.4 0 0.4 0.4 68 4 65 305 30 0 30 0 -3 0 -2.9 -3.1 03/19/2005 08:40:00 9.3 0.6 10.7 7.6 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 67 4 68 305 30 0 30 0 -3 0 -2.9 -3.1 03/19/2005 08:50:00 9.2 0.7 11.5 7.2 9.1 0.7 11.5 6.8 0.4 0 0.4 0.4 68 4 71 305 30 0 31 0 -3.1 0 -2.9 -3.1 03/19/2005 09:00:00 9.3 0.5 10.3 8 9.3 0.5 10.3 8 0.4 0 0.4 0.4 69 3 72 305 30 0 31 0 -3 0 -2.9 -3.1 03/19/2005 09:10:00 9 0.5 10.7 7.6 8.9 0.5 10.7 7.6 0.4 0 0.4 0.4 68 3 67 305 30 0 30 0 -3.1 0 -2.9 -3.1 03/19/2005 09:20:00 8.7 0.7 10.7 7.2 8.7 0.7 10.3 6.8 0.4 0 0.4 0.4 66 4 65 305 30 0 30 0 -3.1 0 -3.1 -3.3 03/19/2005 09:30:00 8.1 0.5 9.5 6.8 8.2 0.5 9.9 6.8 0.4 0 0.4 0.4 64 4 71 305 30 0 30 0 -3.1 0 -3.1 -3.3 03/19/2005 09:40:00 8.3 0.6 9.9 6.8 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 66 4 63 305 30 0 30 0 -3.1 0 -2.7 -3.3 03/19/2005 09:50:00 9 0.6 10.3 7.2 9 0.6 10.7 6.8 0.4 0 0.4 0.4 67 4 63 305 30 0 30 0 -3.1 0 -3.1 -3.1 03/19/2005 10:00:00 8.9 0.5 10.3 8 8.9 0.5 9.9 7.6 0.4 0 0.4 0.4 69 3 72 305 30 0 30 0 -3.1 0 -2.7 -3.1 03/19/2005 10:10:00 8.7 0.7 10.3 7.2 8.7 0.7 10.3 6.8 0.4 0 0.4 0.4 70 4 70 305 30 0 30 0 -3 0 -2.7 -3.1 03/19/2005 10:20:00 8.3 0.8 10.3 6.5 8.4 0.7 10.3 6.8 0.4 0 0.4 0.4 69 5 61 305 30 0 30 0 -3 0 -2.7 -3.1 03/19/2005 10:30:00 9.3 0.7 10.7 6.8 9.3 0.7 11.1 7.2 0.4 0 0.4 0.4 69 3 66 305 30 0 29 0 -3.1 0 -3.1 -3.3 03/19/2005 10:40:00 8.9 0.6 9.9 7.2 8.9 0.6 10.3 7.2 0.4 0 0.4 0.4 68 3 74 305 30 0 30 0 -3.2 0 -2.7 -3.3 03/19/2005 10:50:00 9.1 0.6 10.3 6.8 9 0.7 10.3 6.5 0.4 0 0.4 0.4 65 3 66 305 31 0 31 0 -3.2 0 -3.1 -3.3 03/19/2005 11:00:00 8.4 0.5 9.5 7.2 8.4 0.5 9.5 6.8 0.4 0 0.4 0.4 67 3 69 305 31 0 31 0 -3.1 0 -2.9 -3.3 03/19/2005 11:10:00 8 0.6 9.5 6.8 8.1 0.6 9.5 6.8 0.4 0 0.4 0.4 69 4 70 305 32 0 32 0 -3 0 -2.7 -3.1 03/19/2005 11:20:00 9.2 0.5 10.3 8 9.1 0.6 10.3 7.6 0.4 0 0.4 0.4 69 3 71 305 31 0 32 0 -3 0 -2.7 -3.1 03/19/2005 11:30:00 9.3 0.5 10.7 7.6 9.2 0.5 10.7 8 0.4 0 0.4 0.4 66 3 74 305 31 0 31 0 -3.2 0 -2.7 -3.3 03/19/2005 11:40:00 8.7 0.7 10.3 6.8 8.7 0.7 10.3 6.5 0.4 0 0.4 0.4 66 3 65 305 32 0 32 0 -3.1 0 -3.1 -3.3 03/19/2005 11:50:00 8.8 0.6 9.9 7.2 8.8 0.6 10.3 6.8 0.4 0 0.4 0.4 66 3 67 305 32 0 32 0 -3.1 0 -2.9 -3.3 03/19/2005 12:00:00 8.9 0.5 9.9 7.6 8.9 0.5 9.9 7.2 0.4 0 0.4 0.4 66 3 65 305 32 0 32 0 -3.1 0 -2.7 -3.1 03/19/2005 12:10:00 9.5 0.5 10.7 8.4 9.5 0.6 10.7 8 0.4 0 0.4 0.4 66 3 62 305 32 0 32 0 -3.1 0 -2.9 -3.1 03/19/2005 12:20:00 10.6 0.6 11.8 9.5 10.7 0.6 11.8 9.5 0.4 0 0.4 0.4 69 2 72 305 32 0 32 0 -3.1 0 -2.7 -3.1 03/19/2005 12:30:00 11.3 0.5 12.6 9.9 11.2 0.6 12.2 9.9 0.4 0 0.4 0.4 73 3 76 305 32 0 32 0 -3 0 -2.7 -3.1 03/19/2005 12:40:00 11.6 0.6 12.6 9.5 11.4 0.6 12.6 9.1 0.4 0 0.4 0.4 77 3 76 305 33 0 33 0 -3 0 -2.7 -3.1 03/19/2005 12:50:00 11.1 0.5 12.2 9.5 11 0.6 12.2 9.1 0.4 0 0.4 0.4 77 3 80 305 33 0 33 0 -3 0 -2.7 -3.1 03/19/2005 13:00:00 10.9 0.5 12.2 9.5 10.8 0.6 11.8 9.1 0.4 0 0.4 0.4 72 3 73 305 33 0 33 0 -3 0 -2.7 -3.1 03/19/2005 13:10:00 11.4 0.5 12.2 10.3 11.3 0.5 12.2 9.9 0.4 0 0.4 0.4 70 3 70 305 33 0 33 0 -3 0 -2.4 -3.1 03/19/2005 13:20:00 10.4 0.7 11.5 8 10.3 0.7 11.5 8.4 0.4 0 0.4 0.4 67 4 68 305 33 0 33 0 -2.8 0 -2.7 -3.1 03/19/2005 13:30:00 9.8 0.5 11.5 8 9.8 0.6 11.5 8.4 0.4 0 0.4 0.4 66 4 68 305 32 0 32 0 -2.8 0 -2.7 -2.9 03/19/2005 13:40:00 10.2 0.6 11.5 8.8 10.1 0.7 11.8 8.4 0.4 0 0.4 0.4 65 3 63 305 32 0 32 0 -2.8 0 -2.7 -3.1 03/19/2005 13:50:00 10.1 0.6 11.5 8.4 10 0.6 11.5 8 0.4 0 0.4 0.4 66 3 70 305 31 0 31 0 -2.8 0 -2.7 -2.9 03/19/2005 14:00:00 9.8 0.6 11.5 8.4 9.7 0.6 11.1 8 0.4 0 0.4 0.4 65 3 62 305 31 0 31 0 -2.7 0 -2.4 -2.7 03/19/2005 14:10:00 9.9 0.6 11.5 8 9.8 0.7 11.5 8 0.4 0 0.4 0.4 65 3 65 305 31 0 31 0 -2.7 0 -2.4 -2.7 03/19/2005 14:20:00 9.4 0.6 10.7 7.6 9.4 0.7 11.1 7.2 0.4 0 0.4 0.4 66 4 65 305 31 0 31 0 -2.7 0 -2.4 -2.7 03/19/2005 14:30:00 9.2 0.6 11.1 7.2 9.1 0.7 10.7 6.8 0.4 0 0.4 0.4 68 5 71 305 31 0 31 0 -2.7 0 -2.4 -2.7 03/19/2005 14:40:00 9.8 0.7 11.5 8 9.6 0.8 11.8 7.2 0.4 0 0.4 0.4 69 4 67 305 31 0 31 0 -2.6 0 -2.4 -2.7 03/19/2005 14:50:00 10.3 0.7 11.8 8.4 10.1 0.8 11.8 8 0.4 0 0.4 0.4 72 3 67 305 31 0 31 0 -2.4 0 -2.2 -2.7 03/19/2005 15:00:00 10 0.6 11.8 8 10 0.7 11.5 8 0.4 0 0.4 0.4 69 4 67 305 31 0 31 0 -2.6 0.1 -2.2 -2.7 03/19/2005 15:10:00 9 0.7 11.8 7.2 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 68 5 70 305 30 0 30 0 -2.5 0 -2 -2.7 03/19/2005 15:20:00 9 0.8 11.1 7.2 8.9 0.8 11.1 6.8 0.4 0 0.4 0.4 67 6 70 305 30 0 31 0 -2.4 0 -2 -2.7 03/19/2005 15:30:00 8.5 0.8 9.9 6.8 8.5 0.7 10.3 6.8 0.4 0 0.4 0.4 64 4 65 305 30 0 30 0 -2.5 0 -2.2 -2.7 03/19/2005 15:40:00 8.3 0.8 10.3 6.1 8.2 0.8 10.3 6.5 0.4 0 0.4 0.4 64 5 62 305 30 0 30 0 -2.4 0 -2 -2.7 03/19/2005 15:50:00 8.2 0.8 9.9 6.1 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 66 5 65 305 30 0 30 0 -2.3 0 -2 -2.4 03/19/2005 16:00:00 8.4 0.7 11.1 6.8 8.3 0.7 10.7 6.5 0.4 0 0.4 0.4 66 6 67 305 30 0 30 0 -2.2 0 -1.8 -2.4 03/19/2005 16:10:00 8.3 0.6 10.3 6.5 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 66 5 66 305 30 0 30 0 -2.2 0 -1.8 -2.2 03/19/2005 16:20:00 7.7 0.8 10.3 6.1 7.7 0.8 9.9 5.7 0.4 0 0.4 0.4 64 6 72 305 29 0 29 0 -2.3 0 -1.8 -2.4 03/19/2005 16:30:00 8.2 1 10.7 5.7 8.2 1 10.3 5.3 0.4 0 0.4 0.4 65 6 67 305 29 0 29 0 -2.3 0 -2 -2.4 03/19/2005 16:40:00 7.2 0.8 9.1 5.3 7.1 0.8 9.5 4.9 0.4 0 0.4 0.4 61 7 75 305 29 0 29 0 -2.3 0 -2.2 -2.4 03/19/2005 16:50:00 6.3 0.8 8.4 4.6 6.4 0.8 8.8 4.6 0.4 0 0.4 0.4 56 6 52 305 29 0 29 0 -2.3 0 -2.2 -2.4 03/19/2005 17:00:00 6 0.6 7.6 4.2 6.1 0.7 8 4.2 0.4 0 0.4 0.4 53 6 63 305 29 0 29 0 -2.2 0 -1.8 -2.4 03/19/2005 17:10:00 5.5 0.5 6.8 4.2 5.6 0.6 6.8 4.2 0.4 0 0.4 0.4 49 6 52 305 29 0 29 0 -2.2 0 -2.2 -2.4 03/19/2005 17:20:00 5.2 0.5 6.5 3.8 5.3 0.5 6.5 4.2 0.4 0 0.4 0.4 48 6 46 305 29 0 29 0 -2.2 0 -2.2 -2.4 03/19/2005 17:30:00 6.1 0.7 8 4.9 6.2 0.6 8 4.9 0.4 0 0.4 0.4 53 5 58 305 29 0 29 0 -2.2 0 -2 -2.4 03/19/2005 17:40:00 6.5 0.6 8.4 4.9 6.6 0.6 8 5.3 0.4 0 0.4 0.4 54 5 58 305 29 0 29 0 -2.3 0 -2.2 -2.4 03/19/2005 17:50:00 8.4 0.6 9.5 6.5 8.4 0.6 9.9 6.5 0.4 0 0.4 0.4 60 3 62 305 29 0 29 0 -2.3 0 -1.8 -2.4 03/19/2005 18:00:00 8.8 0.5 9.9 7.2 8.8 0.6 10.3 6.8 0.4 0 0.4 0.4 61 3 62 305 29 0 29 0 -2.3 0 -2.2 -2.4 03/19/2005 18:10:00 8.6 0.6 9.9 6.8 8.5 0.6 9.9 6.1 0.4 0 0.4 0.4 61 4 69 305 30 0 30 0 -2.4 0 -2.2 -2.4 03/19/2005 18:20:00 9.2 0.7 10.7 7.6 9.3 0.7 11.1 7.6 0.4 0 0.4 0.4 64 4 71 305 30 0 31 0 -2.4 0 -2.4 -2.7 03/19/2005 18:30:00 9.7 0.7 11.1 7.6 9.7 0.7 11.5 8 0.4 0 0.4 0.4 65 4 67 305 31 0 31 0 -2.5 0 -2.4 -2.7 03/19/2005 18:40:00 9.9 0.7 11.5 8.4 10 0.8 11.5 7.6 0.4 0 0.4 0.4 67 4 64 305 31 0 31 0 -2.5 0 -2.2 -2.7 03/19/2005 18:50:00 10.5 0.7 11.8 8.4 10.5 0.7 11.8 8.4 0.4 0 0.4 0.4 69 4 71 305 31 0 31 0 -2.4 0 -2.4 -2.7 03/19/2005 19:00:00 10.1 1 12.2 7.2 10 1 12.2 7.2 0.4 0 0.4 0.4 68 4 65 305 32 0 32 0 -2.4 0 -2.4 -2.7 03/19/2005 19:10:00 10 0.9 11.8 7.2 9.9 1 11.8 7.6 0.4 0 0.4 0.4 68 4 64 305 32 0 32 0 -2.4 0 -2.2 -2.4 03/19/2005 19:20:00 10.1 0.7 11.8 8.4 10 0.8 11.8 8 0.4 0 0.4 0.4 69 5 71 305 32 0 32 0 -2.4 0 -2.2 -2.4 03/19/2005 19:30:00 9.7 0.8 11.5 7.2 9.6 0.9 11.8 7.6 0.4 0 0.4 0.4 68 5 67 305 33 0 33 0 -2.4 0 -2.2 -2.7 03/19/2005 19:40:00 9.8 0.7 12.2 8 9.7 0.8 11.8 7.6 0.4 0 0.4 0.4 69 5 79 305 33 0 33 0 -2.5 0 -2.4 -2.7 03/19/2005 19:50:00 10.2 0.7 11.8 8.4 10.1 0.7 11.5 8 0.4 0 0.4 0.4 68 5 67 305 33 0 33 0 -2.5 0 -2.4 -2.7 03/19/2005 20:00:00 11.2 0.7 13 8.8 10.9 0.8 13 8 0.4 0 0.4 0.4 69 4 71 305 34 0 34 0 -2.5 0 -2.4 -2.7 03/19/2005 20:10:00 11.1 0.7 13.3 9.1 10.9 0.8 13 9.1 0.4 0 0.4 0.4 72 4 73 305 34 0 34 0 -2.5 0 -2.4 -2.7 03/19/2005 20:20:00 12 0.9 14.5 9.5 11.7 1 14.1 9.1 0.4 0 0.4 0.4 74 5 76 305 34 0 34 0 -2.6 0 -2.4 -2.7 03/19/2005 20:30:00 12.1 1.1 14.9 7.6 11.7 1.1 14.9 8.8 0.4 0 0.4 0.4 78 6 81 305 35 0 34 0 -2.6 0 -2 -2.7 03/19/2005 20:40:00 12.3 1 15.3 9.9 12.1 1 14.5 9.5 0.4 0 0.4 0.4 75 6 73 305 35 0 34 0 -2.6 0 -2.4 -2.7 03/19/2005 20:50:00 11.9 1 14.9 9.5 11.5 1 14.5 9.1 0.4 0 0.4 0.4 79 8 77 305 35 0 35 0 -2.6 0 -2.4 -2.7 03/19/2005 21:00:00 11.9 1 14.1 9.1 11.4 1.1 13.7 8.8 0.4 0 0.4 0.4 82 6 83 305 35 0 35 0 -2.7 0 -2.4 -2.7 03/19/2005 21:10:00 11.1 1.2 13.7 8.4 10.7 1.2 13.7 7.2 0.4 0 0.4 0.4 79 7 78 305 36 0 35 0 -2.6 0 -2.2 -2.7 03/19/2005 21:20:00 11.1 1.1 13.7 8.8 10.7 1.1 13.7 8.4 0.4 0 0.4 0.4 78 7 70 305 36 0 36 0 -2.7 0.1 -2 -2.7 03/19/2005 21:30:00 11.5 0.8 13.3 8.8 11.3 0.9 13.3 8.4 0.4 0 0.4 0.4 75 6 77 305 36 0 36 0 -2.7 0 -2.4 -2.7 03/19/2005 21:40:00 11.6 1 13.7 9.1 11.4 1 14.1 9.5 0.4 0 0.4 0.4 73 5 71 305 36 0 36 0 -2.7 0 -2.4 -2.7 03/19/2005 21:50:00 11.2 0.8 13.3 9.1 10.9 0.8 13.3 9.1 0.4 0 0.4 0.4 73 4 75 305 37 0 36 0 -2.7 0 -2.4 -2.7 03/19/2005 22:00:00 11.4 0.8 13.3 9.1 11.2 0.8 13.3 8.8 0.4 0 0.4 0.4 73 5 76 305 37 0 37 0 -2.6 0 -2.4 -2.7 03/19/2005 22:10:00 11.1 1 13.7 8 10.8 1 13.7 6.8 0.4 0 0.4 0.4 75 7 66 305 37 0 37 0 -2.6 0 -2 -2.7 03/19/2005 22:20:00 10.3 1.1 14.9 7.2 10 1 13.7 7.2 0.4 0 0.4 0.4 76 9 92 305 37 0 38 0 -2.6 0 -2.4 -2.7 03/19/2005 22:30:00 9.8 0.9 12.6 7.6 9.6 1 12.6 7.6 0.4 0 0.4 0.4 73 7 77 305 38 0 38 0 -2.6 0 -2.4 -2.7 03/19/2005 22:40:00 9.4 0.7 11.5 8 9.3 0.8 11.5 6.8 0.4 0 0.4 0.4 68 4 71 305 38 0 38 0 -2.6 0 -2.4 -2.7 03/19/2005 22:50:00 8.5 0.8 10.7 6.8 8.4 0.8 10.7 6.8 0.4 0 0.4 0.4 67 5 75 305 37 0 38 0 -2.6 0 -2.4 -2.7 03/19/2005 23:00:00 8.1 0.8 10.3 6.1 8 0.8 9.9 5.7 0.4 0 0.4 0.4 66 6 66 305 38 0 38 0 -2.6 0 -2.4 -2.7 03/19/2005 23:10:00 8.1 0.8 10.7 5.7 8.1 0.8 10.3 5.7 0.4 0 0.4 0.4 65 7 81 305 37 0 38 0 -2.6 0 -2.4 -2.7 03/19/2005 23:20:00 8.2 1 11.5 5.7 8 1 11.1 5.7 0.4 0 0.4 0.4 70 8 65 305 37 0 37 0 -2.6 0 -2.2 -2.7 03/19/2005 23:30:00 8.8 0.8 11.8 6.8 8.7 0.8 11.8 6.8 0.4 0 0.4 0.4 70 7 60 305 37 0 37 0 -2.6 0 -2.4 -2.7 03/19/2005 23:40:00 9.6 0.8 12.6 7.2 9.5 0.9 12.6 7.2 0.4 0 0.4 0.4 71 6 74 305 37 0 37 0 -2.6 0 -2.4 -2.7 03/19/2005 23:50:00 9.3 0.9 11.8 7.2 9.1 0.9 11.5 6.8 0.4 0 0.4 0.4 71 6 80 305 37 0 37 0 -2.6 0 -2.4 -2.7 03/20/2005 00:00:00 10 1.2 12.6 7.2 9.6 1.1 12.6 6.8 0.4 0 0.4 0.4 79 6 82 305 37 0 37 0 -2.6 0 -2.2 -2.7 03/20/2005 00:10:00 10.4 0.9 12.6 7.6 10 0.8 11.8 7.2 0.4 0 0.4 0.4 79 6 84 305 37 0 37 0 -2.6 0 -2.2 -2.7 03/20/2005 00:20:00 11.1 0.8 13 8 10.8 0.9 13 8 0.4 0 0.4 0.4 79 5 82 305 37 0 36 0 -2.6 0 -2.4 -2.7 03/20/2005 00:30:00 10.2 0.8 12.2 8 9.9 0.9 12.6 7.2 0.4 0 0.4 0.4 72 7 72 305 36 0 36 0 -2.6 0 -2 -2.7 03/20/2005 00:40:00 10.6 0.7 12.2 8.4 10.6 0.8 12.2 8 0.4 0 0.4 0.4 68 6 68 305 36 0 36 0 -2.6 0 -2.4 -2.7 03/20/2005 00:50:00 10.3 0.6 11.8 8.4 10.3 0.7 11.8 8.4 0.4 0 0.4 0.4 66 3 67 305 35 0 35 0 -2.6 0 -2 -2.7 03/20/2005 01:00:00 8.8 0.8 10.7 6.8 8.8 0.8 10.7 6.8 0.4 0 0.4 0.4 65 5 70 305 35 0 35 0 -2.7 0 -2.4 -2.7 03/20/2005 01:10:00 8.2 0.6 9.9 6.5 8.2 0.6 10.3 6.1 0.4 0 0.4 0.4 65 5 60 305 35 0 35 0 -2.7 0 -2.4 -2.7 03/20/2005 01:20:00 6.4 0.7 7.6 4.9 6.5 0.7 8 4.9 0.4 0 0.4 0.4 56 6 55 305 35 0 35 0 -2.7 0 -2.4 -2.7 03/20/2005 01:30:00 5.6 0.6 7.6 4.2 5.8 0.6 7.6 4.2 0.4 0 0.4 0.4 52 6 50 305 35 0 35 0 -2.8 0 -2.7 -2.7 03/20/2005 01:40:00 6.7 0.7 8.4 4.9 6.8 0.9 8.8 4.9 0.4 0 0.4 0.4 56 5 60 305 36 0 36 0 -2.7 0 -2.7 -2.7 03/20/2005 01:50:00 7.1 0.5 8.4 5.7 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 57 5 66 305 36 0 36 0 -2.7 0 -2.7 -2.7 03/20/2005 02:00:00 7.8 0.5 9.1 6.5 8 0.5 9.1 6.8 0.4 0 0.4 0.4 60 4 54 305 36 0 36 0 -2.7 0 -2 -2.7 03/20/2005 02:10:00 8.6 0.6 9.9 7.2 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 60 3 62 305 36 0 36 0 -2.6 0 -2.4 -2.7 03/20/2005 02:20:00 8.9 0.5 10.3 7.6 8.9 0.5 10.7 7.6 0.4 0 0.4 0.4 58 3 50 305 35 0 35 0 -2.6 0 -2.4 -2.7 03/20/2005 02:30:00 9 0.5 10.7 7.6 9 0.5 10.7 7.6 0.4 0 0.4 0.4 59 3 54 305 34 0 34 0 -2.7 0 -2.4 -2.7 03/20/2005 02:40:00 8.4 0.6 9.5 6.8 8.5 0.5 9.9 7.2 0.4 0 0.4 0.4 58 3 58 305 33 0 33 0 -2.7 0 -2 -2.7 03/20/2005 02:50:00 7.8 0.5 9.1 6.5 8 0.5 9.5 6.8 0.4 0 0.4 0.4 54 4 53 305 33 0 33 0 -2.7 0 -2.4 -2.7 03/20/2005 03:00:00 7.3 0.6 9.1 6.1 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 52 5 48 305 33 0 33 0 -2.7 0 -2.4 -2.7 03/20/2005 03:10:00 7.3 0.7 9.1 5.7 7.4 0.7 9.5 5.7 0.4 0 0.4 0.4 48 6 55 305 33 0 33 0 -2.7 0 -2 -2.7 03/20/2005 03:20:00 7.1 0.8 9.1 5.7 7.2 0.7 9.1 5.3 0.4 0 0.4 0.4 45 4 39 305 34 0 34 0 -2.7 0 -2.7 -2.9 03/20/2005 03:30:00 8.2 0.6 9.9 6.8 8.1 0.6 9.9 6.5 0.4 0 0.4 0.4 45 4 45 305 34 0 34 0 -2.8 0 -2.7 -2.9 03/20/2005 03:40:00 8.5 0.5 9.5 6.8 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 47 4 44 305 34 0 34 0 -2.8 0 -2.7 -2.9 03/20/2005 03:50:00 8.8 0.6 10.3 7.6 8.6 0.6 9.9 7.2 0.4 0 0.4 0.4 48 3 51 305 34 0 34 0 -2.8 0 -2.7 -2.9 03/20/2005 04:00:00 9.5 0.6 11.1 8 9.3 0.7 11.5 7.6 0.4 0 0.4 0.4 50 4 51 305 34 0 34 0 -2.8 0 -2.2 -3.1 03/20/2005 04:10:00 9.1 0.6 10.7 7.6 9 0.6 10.7 8 0.4 0 0.4 0.4 52 4 56 305 35 0 35 0 -2.9 0 -2.7 -3.1 03/20/2005 04:20:00 9.5 0.6 11.1 8 9.3 0.6 10.7 7.6 0.4 0 0.4 0.4 51 4 51 305 35 0 35 0 -2.9 0 -2.7 -3.1 03/20/2005 04:30:00 9.1 0.6 10.3 7.6 8.9 0.6 10.7 7.6 0.4 0 0.4 0.4 51 4 54 305 35 0 35 0 -2.9 0 -2.7 -3.1 03/20/2005 04:40:00 8.8 0.4 9.9 7.6 8.7 0.4 9.9 7.6 0.4 0 0.4 0.4 52 3 56 305 35 0 35 0 -2.9 0 -2.7 -3.1 03/20/2005 04:50:00 9.3 0.6 11.1 8 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 53 3 55 305 35 0 35 0 -3 0 -2.7 -3.1 03/20/2005 05:00:00 9.3 0.7 11.1 7.6 9.2 0.8 11.1 7.6 0.4 0 0.4 0.4 54 4 51 305 35 0 35 0 -3.1 0 -2.9 -3.1 03/20/2005 05:10:00 8.4 0.8 10.7 6.5 8.4 0.8 10.7 6.5 0.4 0 0.4 0.4 49 5 47 305 35 0 35 0 -3 0 -2.4 -3.1 03/20/2005 05:20:00 8.3 0.7 10.3 6.8 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 45 4 48 305 35 0 35 0 -3 0 -2.7 -3.1 03/20/2005 05:30:00 8.7 0.6 10.7 7.2 8.6 0.7 10.3 7.2 0.4 0 0.4 0.4 49 3 47 305 35 0 35 0 -3 0 -2.9 -3.1 03/20/2005 05:40:00 7.7 0.5 9.1 6.5 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 47 4 46 305 35 0 35 0 -3 0 -2.9 -3.1 03/20/2005 05:50:00 7.5 0.6 8.8 6.1 7.6 0.5 8.8 5.7 0.4 0 0.4 0.4 48 4 48 305 35 0 35 0 -3 0 -2.9 -3.1 03/20/2005 06:00:00 7.9 0.6 9.5 6.1 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 48 4 50 305 35 0 35 0 -3.1 0 -2.7 -3.1 03/20/2005 06:10:00 9.3 0.5 10.3 7.6 9.1 0.6 10.7 7.2 0.4 0 0.4 0.4 47 3 47 305 35 0 35 0 -3.1 0 -2.7 -3.1 03/20/2005 06:20:00 9.4 0.6 11.1 8 9.4 0.6 11.8 8 0.4 0 0.4 0.4 47 3 47 305 34 0 34 0 -3.1 0 -2.9 -3.1 03/20/2005 06:30:00 9.6 0.6 11.1 8 9.5 0.6 11.1 7.6 0.4 0 0.4 0.4 47 3 45 305 34 0 34 0 -3.2 0 -3.1 -3.3 03/20/2005 06:40:00 9.2 0.5 10.3 7.6 9.1 0.5 10.7 8 0.4 0 0.4 0.4 46 3 46 305 34 0 34 0 -3.2 0 -3.1 -3.3 03/20/2005 06:50:00 9.8 0.6 11.1 8 9.8 0.6 11.1 8.4 0.4 0 0.4 0.4 45 3 47 305 34 0 34 0 -3.3 0 -3.1 -3.3 03/20/2005 07:00:00 10.1 0.7 11.8 8.4 9.9 0.7 11.8 8.4 0.4 0 0.4 0.4 47 3 44 305 34 0 34 0 -3.3 0 -3.1 -3.3 03/20/2005 07:10:00 9.4 0.6 10.7 8 9.3 0.6 10.7 7.6 0.4 0 0.4 0.4 42 3 44 305 33 0 33 0 -3.3 0 -2.9 -3.6 03/20/2005 07:20:00 10.3 0.6 11.8 8.8 10.2 0.7 12.2 8.4 0.4 0 0.4 0.4 43 4 48 305 33 0 33 0 -3.5 0 -2.9 -3.8 03/20/2005 07:30:00 9.4 0.7 11.1 7.2 9.3 0.7 10.7 7.2 0.4 0 0.4 0.4 47 4 46 305 32 0 32 0 -3.6 0 -3.3 -3.8 03/20/2005 07:40:00 9.5 0.6 11.5 8 9.4 0.7 11.1 7.6 0.4 0 0.4 0.4 44 3 45 305 32 0 32 0 -3.7 0 -3.6 -3.8 03/20/2005 07:50:00 9.2 0.6 10.7 7.6 9.1 0.6 10.3 7.6 0.4 0 0.4 0.4 45 4 39 305 31 0 31 0 -3.9 0 -3.8 -3.8 03/20/2005 08:00:00 9.1 0.5 10.3 8 9 0.5 10.3 7.6 0.4 0 0.4 0.4 46 4 49 305 31 0 31 0 -3.9 0 -3.8 -4 03/20/2005 08:10:00 8.4 0.5 9.5 7.2 8.5 0.6 9.5 6.8 0.4 0 0.4 0.4 44 4 48 305 31 0 31 0 -4 0 -3.8 -4.2 03/20/2005 08:20:00 8.7 0.5 9.9 6.8 8.7 0.5 9.9 7.2 0.4 0 0.4 0.4 43 3 48 305 31 0 31 0 -4.1 0 -4 -4.2 03/20/2005 08:30:00 9.5 0.8 11.1 7.2 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 42 4 39 305 30 0 31 0 -4.1 0 -4 -4.2 03/20/2005 08:40:00 9.9 0.6 11.8 8 9.9 0.6 11.8 8.4 0.4 0 0.4 0.4 42 3 37 305 30 0 30 0 -4.2 0 -3.8 -4.5 03/20/2005 08:50:00 10.4 0.6 11.8 8.8 10.4 0.6 11.8 8.4 0.4 0 0.4 0.4 44 4 41 305 29 0 29 0 -4.3 0 -4 -4.5 03/20/2005 09:00:00 9.3 0.5 10.7 7.6 9.2 0.5 10.7 7.6 0.4 0 0.4 0.4 45 5 40 305 29 0 29 0 -4.4 0 -4.2 -4.5 03/20/2005 09:10:00 9.3 0.6 11.1 7.6 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 49 4 54 305 29 0 29 0 -4.4 0 -4.2 -4.5 03/20/2005 09:20:00 8.4 0.8 10.7 6.8 8.4 0.7 10.3 6.8 0.4 0 0.4 0.4 54 5 56 305 28 0 28 0 -4.4 0 -4.2 -4.7 03/20/2005 09:30:00 9.2 0.8 11.1 6.8 9.1 0.8 11.1 6.8 0.4 0 0.4 0.4 53 4 57 305 28 0 27 0 -4.5 0 -4.2 -4.7 03/20/2005 09:40:00 9.9 0.8 12.2 8 9.7 0.8 11.8 7.6 0.4 0 0.4 0.4 54 4 50 305 26 0 27 0 -4.6 0 -4.5 -4.7 03/20/2005 09:50:00 9.9 1 12.2 7.6 9.8 1 11.8 7.6 0.4 0 0.4 0.4 54 6 48 305 26 0 26 0 -4.5 0 -4.5 -4.7 03/20/2005 10:00:00 8.9 1 11.8 7.2 8.8 1 12.2 6.8 0.4 0 0.4 0.4 53 5 55 305 24 0 25 0 -4.6 0 -4 -4.7 03/20/2005 10:10:00 9.5 0.8 11.5 7.6 9.4 0.9 11.5 7.6 0.4 0 0.4 0.4 51 5 55 305 23 0 23 0 -4.6 0 -4.5 -4.7 03/20/2005 10:20:00 10 0.8 11.8 8 9.9 0.8 11.8 8 0.4 0 0.4 0.4 49 5 46 305 21 0 21 0 -4.5 0 -4 -4.7 03/20/2005 10:30:00 10.6 0.7 12.2 8.4 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 47 4 45 305 20 0 19 0 -4.5 0 -4.5 -4.7 03/20/2005 10:40:00 11.4 0.8 13 9.5 11.3 0.8 13 9.1 0.4 0 0.4 0.4 47 4 48 305 18 0 18 0 -4.6 0 -4.5 -4.7 03/20/2005 10:50:00 12.1 0.7 13.3 9.9 12 0.8 13.7 9.9 0.4 0 0.4 0.4 46 4 48 305 17 0 17 0 -4.6 0 -4.5 -4.7 03/20/2005 11:00:00 12.3 0.5 13.3 10.7 12.2 0.6 13.7 9.9 0.4 0 0.4 0.4 40 3 46 305 16 0 16 0 -4.9 0 -4.7 -5.1 03/20/2005 11:10:00 12.5 0.7 14.1 10.7 12.4 0.8 13.7 9.9 0.4 0 0.4 0.4 38 4 30 305 15 0 15 0 -5 0 -4.9 -5.1 03/20/2005 11:20:00 12.8 0.6 14.1 10.3 12.7 0.7 14.1 10.7 0.4 0 0.4 0.4 38 4 35 305 15 0 15 0 -5.2 0 -5.1 -5.6 03/20/2005 11:30:00 12.2 0.8 14.1 9.9 12.2 0.8 13.7 9.9 0.4 0 0.4 0.4 38 3 40 305 14 0 14 0 -5.4 0 -5.1 -5.6 03/20/2005 11:40:00 12.6 0.6 13.7 10.3 12.4 0.6 13.7 10.7 0.4 0 0.4 0.4 37 3 37 305 13 0 13 0 -5.6 0 -5.6 -5.8 03/20/2005 11:50:00 12.8 0.5 14.1 11.8 12.9 0.5 14.5 11.5 0.4 0 0.4 0.4 39 3 35 305 12 0 12 0 -5.7 0 -5.6 -5.8 03/20/2005 12:00:00 12.6 0.7 14.1 10.7 12.6 0.8 14.5 10.3 0.4 0 0.4 0.4 42 5 43 305 11 0 12 0 -5.7 0 -5.6 -5.8 03/20/2005 12:10:00 12.4 0.7 14.1 9.5 12.3 0.9 14.1 9.1 0.4 0 0.4 0.4 39 3 39 305 11 0 11 0 -5.8 0 -5.6 -5.8 03/20/2005 12:20:00 12.7 0.7 14.1 10.3 12.6 0.8 14.1 10.3 0.4 0 0.4 0.4 42 4 39 305 10 0 11 0 -5.8 0 -5.8 -6 03/20/2005 12:30:00 12.7 0.8 14.5 9.9 12.5 0.9 14.5 9.9 0.4 0 0.4 0.4 42 4 48 305 9 0 9 0 -5.9 0 -5.8 -6 03/20/2005 12:40:00 12.6 1 15.3 9.5 12.4 1.1 14.9 9.1 0.4 0 0.4 0.4 45 4 44 305 9 0 9 0 -5.9 0 -5.8 -6 03/20/2005 12:50:00 12.4 0.9 14.5 9.9 12.4 1 14.5 9.5 0.4 0 0.4 0.4 45 4 45 305 8 0 8 0 -5.9 0 -5.8 -6 03/20/2005 13:00:00 12.5 0.7 14.1 10.3 12.4 0.8 14.1 10.3 0.4 0 0.4 0.4 44 5 54 305 8 0 8 0 -6.1 0 -5.8 -6.2 03/20/2005 13:10:00 12.2 0.7 13.7 9.9 12.1 0.8 14.1 9.9 0.4 0 0.4 0.4 42 4 51 305 8 0 8 0 -6 0 -5.8 -6.2 03/20/2005 13:20:00 11.4 0.9 13 8.8 11.3 1 13 8.4 0.4 0 0.4 0.4 44 4 39 305 8 0 8 0 -5.8 0.1 -5.6 -6 03/20/2005 13:30:00 11.5 1 13.7 8.8 11.3 1.1 13.7 8.8 0.4 0 0.4 0.4 53 5 51 305 7 0 8 0 -5.5 0 -5.1 -5.6 03/20/2005 13:40:00 11.4 0.9 13 8.4 11.2 1 13 8.8 0.4 0 0.4 0.4 53 5 54 305 7 0 7 0 -5.5 0 -5.3 -5.6 03/20/2005 13:50:00 10.8 1.1 13 7.6 10.7 1.2 12.6 7.6 0.4 0 0.4 0.4 59 5 61 305 7 0 7 0 -5.3 0 -5.1 -5.6 03/20/2005 14:00:00 10.5 0.8 12.6 8.4 10.3 1 12.6 8 0.4 0 0.4 0.4 61 5 64 305 7 0 7 0 -5.2 0 -5.1 -5.6 03/20/2005 14:10:00 10.3 0.8 11.8 8.4 10.3 0.8 11.8 8.8 0.4 0 0.4 0.4 62 5 65 305 7 0 7 0 -5.1 0 -4.7 -5.3 03/20/2005 14:20:00 10.6 0.7 12.2 8.8 10.5 0.8 12.2 7.6 0.4 0 0.4 0.4 65 3 66 305 6 0 7 0 -4.9 0 -4.7 -5.1 03/20/2005 14:30:00 9.6 1 11.5 7.2 9.6 1 11.8 7.6 0.4 0 0.4 0.4 66 5 72 305 6 0 7 0 -4.6 0.1 -4 -4.7 03/20/2005 14:40:00 10.9 0.7 12.6 8.8 10.8 0.7 13 8.8 0.4 0 0.4 0.4 64 3 68 305 6 0 6 0 -4.7 0 -4.5 -4.9 03/20/2005 14:50:00 9.6 0.8 11.8 7.6 9.6 0.8 11.8 7.6 0.4 0 0.4 0.4 66 5 68 305 6 0 6 0 -4.5 0.1 -4.2 -4.7 03/20/2005 15:00:00 10.1 0.6 11.5 8 10 0.7 11.5 8 0.4 0 0.4 0.4 64 4 62 305 6 0 6 0 -4.5 0 -4.2 -4.7 03/20/2005 15:10:00 10.2 0.7 11.8 8.4 10.1 0.8 11.8 8.4 0.4 0 0.4 0.4 64 3 65 305 6 0 6 0 -4.6 0 -4.5 -4.7 03/20/2005 15:20:00 10.5 0.8 12.6 8.4 10.4 0.9 12.2 8 0.4 0 0.4 0.4 60 4 62 305 6 0 6 0 -4.9 0 -4.7 -5.1 03/20/2005 15:30:00 10.8 1.1 13 7.2 10.7 1.1 12.6 8 0.4 0 0.4 0.4 62 4 64 305 6 0 6 0 -4.9 0 -4.7 -5.1 03/20/2005 15:40:00 10 0.8 12.6 8.4 9.9 0.8 12.6 8 0.4 0 0.4 0.4 64 4 63 305 5 0 5 0 -4.8 0 -4.7 -4.9 03/20/2005 15:50:00 10.5 0.8 12.2 8 10.3 0.9 12.2 8 0.4 0 0.4 0.4 64 4 65 305 5 0 5 0 -4.9 0 -4.5 -5.1 03/20/2005 16:00:00 11.3 0.6 13 9.1 11.3 0.7 12.6 9.1 0.4 0 0.4 0.4 64 3 62 305 5 0 5 0 -5 0 -4.7 -5.1 03/20/2005 16:10:00 10.5 0.7 12.2 8.4 10.4 0.8 12.2 8.4 0.4 0 0.4 0.4 67 5 71 305 5 0 5 0 -4.9 0 -4.7 -5.1 03/20/2005 16:20:00 11.2 0.8 13 8.8 11.1 0.8 13 8.8 0.4 0 0.4 0.4 66 4 67 305 5 0 5 0 -5 0 -4.7 -5.1 03/20/2005 16:30:00 11.2 0.8 13 9.1 11.1 0.8 13 9.1 0.4 0 0.4 0.4 68 3 71 305 4 0 5 0 -5 0 -4.9 -5.1 03/20/2005 16:40:00 11.4 0.6 13 9.9 11.2 0.7 13 9.1 0.4 0 0.4 0.4 69 4 68 305 4 0 4 0 -5 0 -4.9 -5.1 03/20/2005 16:50:00 11.7 0.6 13.3 9.9 11.5 0.7 13.3 9.5 0.4 0 0.4 0.4 67 3 67 305 4 0 4 0 -5.2 0 -4.9 -5.3 03/20/2005 17:00:00 10.4 0.7 11.8 8 10.2 0.7 12.2 8 0.4 0 0.4 0.4 69 4 67 305 4 0 4 0 -5.1 0 -4.9 -5.3 03/20/2005 17:10:00 9.8 0.6 11.1 8 9.6 0.7 11.5 8 0.4 0 0.4 0.4 73 4 77 305 4 0 4 0 -5 0 -4.7 -5.1 03/20/2005 17:20:00 10 0.8 11.8 7.6 9.8 0.9 12.2 7.6 0.4 0 0.4 0.4 70 5 65 305 4 0 4 0 -5 0 -4.7 -5.1 03/20/2005 17:30:00 10.3 0.5 11.8 8.4 10.2 0.6 11.8 8 0.4 0 0.4 0.4 71 3 72 305 4 0 4 0 -5 0 -4.7 -5.1 03/20/2005 17:40:00 10.2 0.8 11.5 8 10.1 0.8 11.8 8 0.4 0 0.4 0.4 68 3 65 305 4 0 4 0 -5 0 -4.9 -5.1 03/20/2005 17:50:00 9.7 0.6 11.1 8 9.6 0.7 11.1 8 0.4 0 0.4 0.4 68 4 64 305 4 0 4 0 -5 0 -4.7 -5.1 03/20/2005 18:00:00 9.7 0.7 11.1 7.6 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 69 4 66 305 3 0 4 0 -5 0 -4.7 -5.1 03/20/2005 18:10:00 9.7 0.7 11.1 8 9.6 0.8 11.5 7.6 0.4 0 0.4 0.4 68 4 72 305 3 0 4 0 -5 0 -4.7 -5.1 03/20/2005 18:20:00 9.3 0.8 11.1 7.6 9.2 0.8 11.1 6.8 0.4 0 0.4 0.4 69 3 69 305 3 0 4 0 -5 0 -4.7 -5.1 03/20/2005 18:30:00 9.3 0.6 11.1 7.6 9.2 0.7 11.1 6.8 0.4 0 0.4 0.4 68 4 65 305 3 0 3 0 -5 0 -4.7 -5.1 03/20/2005 18:40:00 9.3 0.6 10.7 7.6 9.2 0.7 10.7 7.6 0.4 0 0.4 0.4 69 4 72 305 3 0 3 0 -5 0 -4.9 -5.1 03/20/2005 18:50:00 8.9 0.5 10.3 7.6 8.7 0.5 9.9 6.8 0.4 0 0.4 0.4 70 4 68 305 3 0 3 0 -5 0 -4.7 -5.1 03/20/2005 19:00:00 8.5 0.7 10.3 6.8 8.4 0.7 10.3 6.8 0.4 0 0.4 0.4 69 5 74 305 3 0 3 0 -4.9 0 -4.7 -5.1 03/20/2005 19:10:00 7.3 0.6 9.1 5.7 7.3 0.5 8.4 6.1 0.4 0 0.4 0.4 65 4 66 305 3 0 3 0 -4.9 0 -4.7 -5.1 03/20/2005 19:20:00 7.6 0.6 9.1 5.7 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 68 5 69 305 3 0 3 0 -5 0 -4.9 -5.1 03/20/2005 19:30:00 7.4 0.6 9.1 5.7 7.4 0.6 9.1 5.7 0.4 0 0.4 0.4 63 4 63 305 3 0 3 0 -5.2 0.1 -4.9 -5.6 03/20/2005 19:40:00 7.6 0.6 9.5 6.1 7.6 0.6 9.5 6.1 0.4 0 0.4 0.4 63 4 71 305 3 0 3 0 -5.3 0 -5.1 -5.6 03/20/2005 19:50:00 7.8 0.7 9.9 5.3 7.7 0.8 9.5 5.7 0.4 0 0.4 0.4 63 5 65 305 3 0 3 0 -5.5 0 -5.3 -5.6 03/20/2005 20:00:00 8.4 0.8 9.9 6.1 8.3 0.8 9.9 6.1 0.4 0 0.4 0.4 63 5 58 305 4 0 4 0 -5.5 0 -5.1 -5.8 03/20/2005 20:10:00 8.4 0.9 10.3 5.7 8.2 0.8 10.3 6.1 0.4 0 0.4 0.4 63 5 61 305 4 0 4 0 -5.8 0.1 -5.6 -6 03/20/2005 20:20:00 8.5 0.9 11.8 6.5 8.2 0.8 10.7 6.5 0.4 0 0.4 0.4 60 6 67 305 4 0 4 0 -6 0 -5.8 -6 03/20/2005 20:30:00 9.1 0.8 11.8 7.2 9 0.8 11.8 7.6 0.4 0 0.4 0.4 63 5 61 305 4 0 4 0 -6 0 -5.8 -6 03/20/2005 20:40:00 9.2 0.7 10.7 7.2 9.1 0.8 11.1 7.2 0.4 0 0.4 0.4 62 4 63 305 4 0 4 0 -6 0 -5.8 -6.2 03/20/2005 20:50:00 7.4 1.2 10.7 5.7 7.3 1.1 9.9 5.7 0.4 0 0.4 0.4 57 5 60 305 4 0 4 0 -6.1 0 -5.8 -6.2 03/20/2005 21:00:00 9.3 1.1 11.8 6.5 9.1 1.1 11.8 6.8 0.4 0 0.4 0.4 55 6 52 305 5 0 5 0 -5.9 0 -5.6 -6 03/20/2005 21:10:00 8.8 0.7 11.1 6.8 8.7 0.7 10.3 6.5 0.4 0 0.4 0.4 61 5 53 305 5 0 5 0 -6.1 0 -5.8 -6.4 03/20/2005 21:20:00 7 0.9 9.1 4.9 7 0.9 9.1 4.9 0.4 0 0.4 0.4 58 6 63 305 5 0 5 0 -6.4 0.1 -6.2 -6.7 03/20/2005 21:30:00 8.3 0.9 10.3 6.1 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 52 5 58 305 5 0 5 0 -6.2 0.1 -6 -6.4 03/20/2005 21:40:00 8.3 0.6 9.9 6.8 8.2 0.7 9.9 6.8 0.4 0 0.4 0.4 48 5 48 305 5 0 6 0 -6 0 -5.8 -6.2 03/20/2005 21:50:00 9.9 0.8 11.5 7.6 9.8 0.9 12.2 6.8 0.4 0 0.4 0.4 48 5 48 305 6 0 6 0 -5.9 0 -5.8 -6 03/20/2005 22:00:00 10.2 0.8 11.8 8.4 10.1 0.8 12.2 8 0.4 0 0.4 0.4 48 4 46 305 6 0 6 0 -6 0 -5.8 -6 03/20/2005 22:10:00 11 1 13 8.4 10.8 1 13 8 0.4 0 0.4 0.4 46 6 56 305 6 0 6 0 -6.1 0 -5.8 -6.2 03/20/2005 22:20:00 11.4 1 14.1 8.8 11.3 1.1 14.1 8.8 0.4 0 0.4 0.4 44 5 42 305 6 0 6 0 -6.2 0 -6 -6.4 03/20/2005 22:30:00 11.9 0.9 14.1 9.9 11.7 1 14.1 9.1 0.4 0 0.4 0.4 47 5 51 305 6 0 6 0 -6.3 0.1 -6 -6.7 03/20/2005 22:40:00 11 1.1 14.1 8.4 10.9 1.1 13.7 8.4 0.4 0 0.4 0.4 49 5 44 305 6 0 6 0 -6.5 0 -6.4 -6.7 03/20/2005 22:50:00 10.9 1.1 14.1 8 10.6 1.2 13.7 7.6 0.4 0 0.4 0.4 53 6 53 305 6 0 6 0 -6.8 0 -6.7 -6.9 03/20/2005 23:00:00 10.2 1.1 13 8 10 1.1 12.6 8 0.4 0 0.4 0.4 49 5 43 305 6 0 6 0 -6.8 0 -6.7 -6.9 03/20/2005 23:10:00 11.4 0.8 13.3 8.8 11.2 0.9 13.3 8.4 0.4 0 0.4 0.4 50 5 48 305 6 0 6 0 -6.9 0 -6.4 -7.1 03/20/2005 23:20:00 11.7 0.9 14.5 9.1 11.6 0.9 14.1 9.1 0.4 0 0.4 0.4 52 5 55 305 6 0 6 0 -7 0 -6.9 -7.1 03/20/2005 23:30:00 10.4 0.9 12.6 8.4 10.3 1 12.6 7.6 0.4 0 0.4 0.4 53 5 57 305 6 0 6 0 -7.1 0 -6.7 -7.3 03/20/2005 23:40:00 10.3 0.9 12.2 7.2 10.2 0.9 12.6 7.6 0.4 0 0.4 0.4 55 5 54 305 6 0 6 0 -7.1 0 -6.9 -7.3 03/20/2005 23:50:00 8.8 1.1 11.5 6.8 8.7 1.1 11.8 6.1 0.4 0 0.4 0.4 58 6 57 305 6 0 6 0 -7.3 0 -6.9 -7.5 03/21/2005 00:00:00 9.2 1.1 12.2 6.8 9.1 1.1 11.8 6.8 0.4 0 0.4 0.4 60 6 68 305 6 0 6 0 -7.4 0 -7.1 -7.5 03/21/2005 00:10:00 9.3 0.9 11.8 7.2 9.3 0.9 11.8 7.2 0.4 0 0.4 0.4 56 6 62 305 6 0 6 0 -7.2 0 -7.1 -7.5 03/21/2005 00:20:00 9.4 0.7 11.1 7.6 9.4 0.8 11.5 6.8 0.4 0 0.4 0.4 51 5 42 305 7 0 7 0 -7.1 0 -7.1 -7.3 03/21/2005 00:30:00 9.5 0.9 11.5 7.2 9.5 0.8 11.5 7.6 0.4 0 0.4 0.4 50 5 46 305 7 0 7 0 -7.1 0 -7.1 -7.3 03/21/2005 00:40:00 9.5 0.8 11.5 7.6 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 49 5 48 305 7 0 7 0 -7.1 0 -6.7 -7.3 03/21/2005 00:50:00 9.5 0.7 11.8 7.6 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 46 5 45 305 7 0 7 0 -7.1 0 -6.9 -7.3 03/21/2005 01:00:00 9 1 11.5 6.8 8.8 1 11.5 6.5 0.4 0 0.4 0.4 46 5 51 305 7 0 7 0 -7.1 0 -6.9 -7.3 03/21/2005 01:10:00 9.3 0.7 11.1 7.2 9.1 0.8 11.8 7.2 0.4 0 0.4 0.4 47 5 52 305 7 0 7 0 -7.1 0 -6.9 -7.3 03/21/2005 01:20:00 9.8 0.8 11.5 7.2 9.8 0.9 11.5 7.2 0.4 0 0.4 0.4 44 5 50 305 7 0 7 0 -7 0 -6.9 -7.1 03/21/2005 01:30:00 10.6 0.6 12.2 8.8 10.4 0.7 12.2 8.4 0.4 0 0.4 0.4 47 4 53 305 7 0 7 0 -6.9 0 -6.9 -7.1 03/21/2005 01:40:00 9.9 1 11.8 8 9.7 1 12.2 7.6 0.4 0 0.4 0.4 46 5 48 305 7 0 7 0 -6.9 0 -6.7 -7.1 03/21/2005 01:50:00 10.1 0.9 11.8 7.6 9.8 0.9 12.2 8 0.4 0 0.4 0.4 53 6 45 305 7 0 7 0 -7 0 -6.9 -7.3 03/21/2005 02:00:00 10.2 1 12.6 8 9.9 1.1 12.6 6.8 0.4 0 0.4 0.4 51 5 57 305 7 0 7 0 -7.2 0 -7.1 -7.3 03/21/2005 02:10:00 11.1 1 13 8.4 10.8 1 13 8.4 0.4 0 0.4 0.4 47 5 47 305 7 0 7 0 -7.1 0 -7.1 -7.3 03/21/2005 02:20:00 10.6 0.9 13 8.8 10.5 0.8 12.6 8.4 0.4 0 0.4 0.4 46 5 41 305 7 0 7 0 -7.1 0 -7.1 -7.3 03/21/2005 02:30:00 10.8 0.9 13 8.4 10.7 0.9 13 8 0.4 0 0.4 0.4 47 4 46 305 8 0 8 0 -7.1 0 -7.1 -7.3 03/21/2005 02:40:00 11.3 1 13.3 8.8 11 1 13.3 8.8 0.4 0 0.4 0.4 47 4 39 305 8 0 8 0 -7.1 0 -6.9 -7.3 03/21/2005 02:50:00 10.9 1 13.3 8 10.5 1 13.3 7.6 0.4 0 0.4 0.4 44 5 46 305 8 0 8 0 -7.1 0 -6.9 -7.3 03/21/2005 03:00:00 11.6 0.9 13.3 8.8 11.2 1 13.3 8.8 0.4 0 0.4 0.4 48 5 50 305 8 0 8 0 -7.1 0 -6.9 -7.3 03/21/2005 03:10:00 11.4 1 13 8.8 11 1 13 8.4 0.4 0 0.4 0.4 45 4 45 305 8 0 8 0 -7 0 -6.9 -7.3 03/21/2005 03:20:00 10.7 1.1 13 8 10.5 1.2 13 8 0.4 0 0.4 0.4 46 4 48 305 7 0 7 0 -7 0 -6.9 -7.1 03/21/2005 03:30:00 10.1 1 12.2 7.6 9.8 1 11.8 7.6 0.4 0 0.4 0.4 40 7 47 305 7 0 7 0 -6.8 0 -6.7 -7.1 03/21/2005 03:40:00 10.5 1.1 12.6 8 10.3 1.1 12.2 7.6 0.4 0 0.4 0.4 34 5 31 305 8 0 8 0 -6.8 0 -6.7 -6.9 03/21/2005 03:50:00 10 0.8 11.8 7.6 9.8 0.8 11.8 8 0.4 0 0.4 0.4 32 5 28 305 8 0 8 0 -6.8 0 -6.7 -6.9 03/21/2005 04:00:00 11 0.6 12.2 9.1 10.7 0.8 12.2 8.8 0.4 0 0.4 0.4 30 4 29 305 8 0 8 0 -6.9 0 -6.7 -7.1 03/21/2005 04:10:00 10.6 0.8 12.2 8.4 10.3 0.9 12.6 7.6 0.4 0 0.4 0.4 31 4 32 305 8 0 7 0 -6.8 0 -6.7 -6.9 03/21/2005 04:20:00 9.6 1 11.8 6.8 9.5 1 11.8 6.8 0.4 0 0.4 0.4 33 6 33 305 8 0 8 0 -6.7 0 -6.7 -6.9 03/21/2005 04:30:00 9.6 0.8 11.5 6.8 9.5 0.9 11.5 6.8 0.4 0 0.4 0.4 32 5 29 305 8 0 8 0 -6.7 0 -6.2 -6.9 03/21/2005 04:40:00 9.5 1 11.5 6.5 9.5 1 11.8 6.5 0.4 0 0.4 0.4 26 5 22 305 8 0 8 0 -6.7 0 -6.7 -6.9 03/21/2005 04:50:00 10.8 0.8 12.2 8.8 10.8 0.9 12.2 8 0.4 0 0.4 0.4 24 5 18 305 8 0 8 0 -6.7 0 -6.7 -6.9 03/21/2005 05:00:00 11.2 0.7 13 8.4 11.2 0.9 13 8.4 0.4 0 0.4 0.4 21 4 21 305 8 0 8 0 -6.8 0 -6.7 -6.9 03/21/2005 05:10:00 11.8 0.9 13.7 9.5 11.8 1 14.5 8.4 0.4 0 0.4 0.4 20 5 19 305 8 0 8 0 -6.9 0 -6.7 -7.1 03/21/2005 05:20:00 11.9 0.8 13.7 8.8 11.9 0.9 14.1 8.8 0.4 0 0.4 0.4 20 5 25 305 8 0 8 0 -7 0 -6.9 -7.1 03/21/2005 05:30:00 12.8 0.8 14.5 9.5 12.8 0.9 14.5 9.9 0.4 0 0.4 0.4 19 5 18 305 8 0 8 0 -6.9 0 -6.7 -7.1 03/21/2005 05:40:00 12.8 1 15.6 9.5 12.9 1.1 15.3 9.5 0.4 0 0.4 0.4 15 5 17 305 8 0 8 0 -6.9 0 -6.7 -7.1 03/21/2005 05:50:00 12.7 0.8 14.5 10.7 12.7 0.8 14.5 10.7 0.4 0 0.4 0.4 14 4 13 305 8 0 8 0 -7 0 -6.9 -7.1 03/21/2005 06:00:00 13.4 1 15.6 10.7 13.4 1 16.1 10.7 0.4 0 0.4 0.4 13 3 16 305 8 0 8 0 -7.1 0 -6.9 -7.3 03/21/2005 06:10:00 13.1 1 14.9 10.3 13.1 1 15.3 9.5 0.4 0 0.4 0.4 14 4 12 305 9 0 8 0 -7.1 0 -6.9 -7.3 03/21/2005 06:20:00 12.9 1 15.3 10.3 12.9 1 15.3 9.9 0.4 0 0.4 0.4 16 4 17 305 9 0 9 0 -7 0 -6.7 -7.1 03/21/2005 06:30:00 12.2 0.9 14.1 9.9 12.2 1 14.5 9.1 0.4 0 0.4 0.4 16 4 7 305 9 0 9 0 -6.9 0 -6.7 -7.1 03/21/2005 06:40:00 12.9 1 14.9 9.5 12.8 1 15.3 9.1 0.4 0 0.4 0.4 21 5 21 305 9 0 9 0 -6.9 0 -6.7 -7.1 03/21/2005 06:50:00 12.7 0.8 14.5 10.3 12.6 1 14.5 9.9 0.4 0 0.4 0.4 26 6 25 305 9 0 9 0 -6.8 0 -6.7 -6.9 03/21/2005 07:00:00 12.7 0.8 14.5 10.3 12.7 1 15.3 9.1 0.4 0 0.4 0.4 20 5 12 305 9 0 9 0 -6.7 0 -6.7 -6.9 03/21/2005 07:10:00 12.4 0.9 14.1 9.9 12.4 1 14.9 9.9 0.4 0 0.4 0.4 19 4 19 305 8 0 8 0 -6.6 0 -6.4 -6.9 03/21/2005 07:20:00 12.8 1.2 15.6 9.9 12.8 1.2 15.6 9.9 0.4 0 0.4 0.4 17 5 14 305 8 0 8 0 -6.7 0 -6.7 -6.9 03/21/2005 07:30:00 13.2 1 15.3 10.7 13.2 1.1 15.3 10.7 0.4 0 0.4 0.4 16 5 16 305 8 0 8 0 -6.7 0 -6.7 -6.9 03/21/2005 07:40:00 13 1.2 15.6 9.5 12.9 1.4 15.6 9.5 0.4 0 0.4 0.4 18 5 14 305 8 0 8 0 -6.8 0 -6.7 -6.9 03/21/2005 07:50:00 12.1 0.9 14.1 8.8 12.2 0.9 14.1 9.9 0.4 0 0.4 0.4 14 5 22 305 8 0 8 0 -6.8 0 -6.7 -6.9 03/21/2005 08:00:00 13.2 1.2 15.6 10.3 13.2 1.2 15.6 10.3 0.4 0 0.4 0.4 15 5 8 305 8 0 8 0 -6.9 0 -6.7 -7.1 03/21/2005 08:10:00 12.6 0.9 14.5 10.3 12.6 1 14.5 9.5 0.4 0 0.4 0.4 5 4 9 305 8 0 7 0 -7.4 0.2 -6.9 -7.7 03/21/2005 08:20:00 12.6 1 14.5 9.5 12.6 1 14.9 9.5 0.4 0 0.4 0.4 7 4 9 305 8 0 8 0 -7.7 0 -7.5 -7.9 03/21/2005 08:30:00 12.9 1.2 14.9 9.1 13 1.1 15.3 9.5 0.4 0 0.4 0.4 11 4 14 305 8 0 8 0 -7.7 0 -7.7 -7.9 03/21/2005 08:40:00 13.2 1.2 16.4 9.9 13.2 1.3 16.1 9.9 0.4 0 0.4 0.4 14 4 9 305 8 0 8 0 -7.8 0 -7.7 -7.9 03/21/2005 08:50:00 13.5 1.3 16.1 9.1 13.5 1.3 16.4 9.9 0.4 0 0.4 0.4 15 4 10 305 8 0 8 0 -7.9 0 -7.5 -7.9 03/21/2005 09:00:00 13.3 1.4 16.1 9.9 13.4 1.5 16.1 9.9 0.4 0 0.4 0.4 13 5 13 305 8 0 7 0 -7.9 0 -7.7 -8.2 03/21/2005 09:10:00 13.6 0.9 15.6 10.3 13.7 1 15.6 10.3 0.4 0 0.4 0.4 14 4 15 305 7 0 7 0 -8.2 0 -7.9 -8.4 03/21/2005 09:20:00 13.4 1.1 15.6 9.9 13.3 1.2 15.6 9.1 0.4 0 0.4 0.4 15 5 10 305 7 0 7 0 -8.2 0 -7.9 -8.4 03/21/2005 09:30:00 13.3 1.2 15.6 9.9 13.2 1.3 16.1 9.5 0.4 0 0.4 0.4 15 4 19 305 7 0 7 0 -8.2 0 -7.9 -8.2 03/21/2005 09:40:00 13.3 1 15.3 10.7 13.3 1 15.6 10.7 0.4 0 0.4 0.4 17 4 17 305 7 0 7 0 -8.2 0 -8.2 -8.4 03/21/2005 09:50:00 13.1 1 15.3 9.9 13 1.1 15.6 10.3 0.4 0 0.4 0.4 17 4 14 305 7 0 7 0 -8.2 0 -7.9 -8.2 03/21/2005 10:00:00 14 1.2 16.4 11.1 13.8 1.2 16.8 10.7 0.4 0 0.4 0.4 12 4 9 305 7 0 7 0 -8 0 -7.9 -8.2 03/21/2005 10:10:00 14.3 1 16.8 11.5 14.2 1.1 17.2 11.1 0.4 0 0.4 0.4 10 3 7 305 7 0 7 0 -7.9 0 -7.7 -8.2 03/21/2005 10:20:00 15.1 1.1 17.2 11.8 15 1.3 17.6 9.9 0.4 0 0.4 0.4 9 4 12 305 7 0 6 0 -7.7 0 -7.7 -7.9 03/21/2005 10:30:00 13.6 1.3 16.4 10.3 13.6 1.3 16.8 10.7 0.4 0 0.4 0.4 8 5 11 305 7 0 7 0 -7.7 0 -7.5 -7.9 03/21/2005 10:40:00 13.4 1.2 15.6 9.9 13.4 1.3 16.1 9.9 0.4 0 0.4 0.4 12 5 11 305 6 0 6 0 -7.7 0 -7.7 -7.9 03/21/2005 10:50:00 13.3 1.2 15.6 9.9 13.2 1.3 15.6 9.9 0.4 0 0.4 0.4 13 3 12 305 6 0 6 0 -7.7 0 -7.5 -7.7 03/21/2005 11:00:00 14.4 1 16.8 12.2 14.4 1 17.2 11.8 0.4 0 0.4 0.4 15 4 14 305 6 0 6 0 -7.5 0 -7.3 -7.7 03/21/2005 11:10:00 13.3 1.5 16.8 9.5 13.1 1.6 16.8 9.9 0.4 0 0.4 0.4 17 5 15 305 6 0 6 0 -7.3 0 -7.1 -7.7 03/21/2005 11:20:00 15.7 1.3 18.3 11.5 15.5 1.3 17.9 11.5 0.4 0 0.4 0.4 18 3 19 305 6 0 6 0 -7.2 0 -7.1 -7.5 03/21/2005 11:30:00 14.4 1.3 17.2 10.7 14.3 1.5 17.2 9.5 0.4 0 0.4 0.4 20 5 21 305 5 0 6 0 -7.4 0.1 -7.1 -7.7 03/21/2005 11:40:00 14 1 16.4 11.5 14 1.1 16.4 11.1 0.4 0 0.4 0.4 20 4 17 305 5 0 5 0 -7.4 0 -7.3 -7.5 03/21/2005 11:50:00 13.5 1.1 16.1 10.3 13.4 1.2 16.1 10.3 0.4 0 0.4 0.4 24 5 21 305 5 0 5 0 -7.1 0 -7.1 -7.3 03/21/2005 12:00:00 14.8 1.1 17.2 11.5 14.6 1.2 17.2 11.1 0.4 0 0.4 0.4 23 4 21 305 5 0 5 0 -7.2 0 -7.1 -7.5 03/21/2005 12:10:00 14.1 1.4 17.2 9.5 14.1 1.5 17.2 9.5 0.4 0 0.4 0.4 18 4 20 305 5 0 5 0 -7.1 0 -7.1 -7.3 03/21/2005 12:20:00 14.7 1.4 17.6 11.1 14.5 1.5 17.6 10.7 0.4 0 0.4 0.4 22 5 28 305 5 0 5 0 -7.1 0 -6.9 -7.3 03/21/2005 12:30:00 13.3 1.3 16.1 9.9 13.2 1.3 16.4 8.8 0.4 0 0.4 0.4 20 5 22 305 5 0 5 0 -7.1 0.1 -6.9 -7.5 03/21/2005 12:40:00 14 1 16.1 11.1 13.9 1 16.1 11.1 0.4 0 0.4 0.4 17 5 17 305 5 0 5 0 -7.4 0 -7.1 -7.5 03/21/2005 12:50:00 13.8 1.1 16.1 10.3 13.5 1.2 16.4 9.9 0.4 0 0.4 0.4 18 5 13 305 5 0 5 0 -7.3 0.1 -7.1 -7.7 03/21/2005 13:00:00 13.2 1.2 15.6 10.3 13 1.3 15.6 9.9 0.4 0 0.4 0.4 20 6 18 305 5 0 5 0 -7.2 0 -7.1 -7.5 03/21/2005 13:10:00 13.1 1.2 16.1 9.9 12.9 1.2 15.6 9.5 0.4 0 0.4 0.4 25 5 24 305 5 0 5 0 -7.1 0 -6.9 -7.3 03/21/2005 13:20:00 13.7 1.4 16.8 9.5 13.6 1.5 16.4 9.5 0.4 0 0.4 0.4 28 5 28 305 5 0 5 0 -7 0 -6.9 -7.1 03/21/2005 13:30:00 13.9 1.2 17.6 10.7 13.6 1.2 16.8 10.7 0.4 0 0.4 0.4 26 6 31 305 4 0 5 0 -6.8 0 -6.7 -7.1 03/21/2005 13:40:00 13.9 1.3 16.8 9.9 13.6 1.3 17.2 10.3 0.4 0 0.4 0.4 26 5 35 305 4 0 5 0 -6.8 0 -6.7 -6.9 03/21/2005 13:50:00 13.7 1.2 16.1 9.5 13.6 1.2 16.1 9.5 0.4 0 0.4 0.4 23 5 21 305 4 0 4 0 -6.7 0 -6.7 -6.9 03/21/2005 14:00:00 14.8 1.5 17.6 11.5 14.5 1.5 17.9 11.1 0.4 0 0.4 0.4 22 5 37 305 4 0 4 0 -6.6 0 -6.7 -6.9 03/21/2005 14:10:00 14.6 1.2 17.2 10.7 14.3 1.2 16.8 11.1 0.4 0 0.4 0.4 21 5 23 305 4 0 4 0 -6.7 0 -6.7 -6.9 03/21/2005 14:20:00 14 1.1 17.2 11.1 13.9 1.2 16.4 10.3 0.4 0 0.4 0.4 21 6 22 305 4 0 4 0 -6.6 0 -6.7 -6.9 03/21/2005 14:30:00 14.7 1.3 17.9 10.7 14.6 1.4 17.6 10.3 0.4 0 0.4 0.4 19 5 18 305 4 0 4 0 -6.7 0 -6.7 -6.9 03/21/2005 14:40:00 15.9 1 18.3 13 15.7 1 17.9 12.6 0.4 0 0.4 0.4 21 4 17 305 4 0 4 0 -6.9 0 -6.7 -7.1 03/21/2005 14:50:00 15.2 1.3 18.3 11.8 15.1 1.3 18.3 11.1 0.4 0 0.4 0.4 22 5 18 305 4 0 4 0 -6.9 0 -6.7 -7.1 03/21/2005 15:00:00 15.8 1.5 18.3 11.8 15.7 1.5 18.3 11.1 0.4 0 0.4 0.4 20 5 17 305 4 0 4 0 -7 0.1 -6.7 -7.3 03/21/2005 15:10:00 16.6 1.3 19.5 13 16.4 1.5 19.5 12.2 0.4 0 0.4 0.4 19 4 22 305 4 0 5 0 -7.2 0 -7.1 -7.5 03/21/2005 15:20:00 16.9 1.1 19.1 13.7 16.6 1.2 19.1 13.3 0.4 0 0.4 0.4 21 5 19 305 6 0 6 0 -7.2 0 -6.9 -7.5 03/21/2005 15:30:00 16.3 1.6 18.7 11.1 16.1 1.6 18.7 10.7 0.4 0 0.4 0.4 17 4 15 305 7 0 7 0 -7.1 0 -6.9 -7.3 03/21/2005 15:40:00 15.3 1.6 18.3 10.7 15.1 1.7 18.3 11.1 0.4 0 0.4 0.4 18 5 23 305 7 0 7 0 -7 0 -6.7 -7.1 03/21/2005 15:50:00 15.5 1.5 17.9 11.5 15.4 1.5 18.3 11.1 0.4 0 0.4 0.4 18 5 21 305 6 0 5 0 -6.9 0 -6.7 -7.1 03/21/2005 16:00:00 16.8 1.4 19.5 11.8 16.6 1.5 19.5 12.2 0.4 0 0.4 0.4 19 4 23 305 6 0 6 0 -7 0 -6.9 -7.1 03/21/2005 16:10:00 16.2 1.6 19.5 11.8 15.9 1.7 19.5 11.8 0.4 0 0.4 0.4 22 6 22 305 8 1 7 0 -6.9 0 -6.7 -7.1 03/21/2005 16:20:00 16.8 1.6 19.9 12.2 16.6 1.7 20.2 12.6 0.4 0 0.4 0.4 23 5 19 305 10 0 9 0 -7 0.1 -6.7 -7.1 03/21/2005 16:30:00 16 1.5 19.5 12.6 15.6 1.6 19.5 12.2 0.4 0 0.4 0.4 20 4 15 305 10 0 10 0 -7 0 -6.9 -7.1 03/21/2005 16:40:00 15.9 1.7 19.1 11.5 15.7 1.8 19.1 10.7 0.4 0 0.4 0.4 20 5 22 305 9 0 10 0 -6.8 0 -6.7 -6.9 03/21/2005 16:50:00 16 1.5 18.3 10.3 15.8 1.6 18.7 10.7 0.4 0 0.4 0.4 18 3 19 305 7 0 8 0 -6.8 0.1 -6.4 -7.1 03/21/2005 17:00:00 14.9 1.2 17.6 11.1 14.7 1.3 18.7 11.1 0.4 0 0.4 0.4 18 4 17 305 6 0 6 0 -6.5 0 -6.4 -6.9 03/21/2005 17:10:00 15.4 1.5 18.7 11.5 15.2 1.5 18.3 11.1 0.4 0 0.4 0.4 18 4 18 305 5 0 5 0 -6.4 0 -6.2 -6.7 03/21/2005 17:20:00 15.6 1.4 18.7 11.5 15.3 1.5 18.7 11.5 0.4 0 0.4 0.4 19 4 17 305 5 0 5 0 -6.2 0 -6 -6.4 03/21/2005 17:30:00 16.5 1.5 19.1 11.8 16.4 1.6 19.5 11.8 0.4 0 0.4 0.4 17 4 21 305 5 0 4 0 -6.5 0 -6.2 -6.7 03/21/2005 17:40:00 15.9 1.3 18.7 12.2 15.8 1.5 18.7 11.8 0.4 0 0.4 0.4 15 4 13 305 5 0 5 0 -6.5 0 -6.4 -6.9 03/21/2005 17:50:00 15.7 1.3 18.7 11.1 15.6 1.3 18.7 11.8 0.4 0 0.4 0.4 18 4 17 305 5 0 5 0 -6.7 0 -6.7 -6.9 03/21/2005 18:00:00 16.5 1.2 19.1 12.2 16.2 1.3 18.7 12.6 0.4 0 0.4 0.4 16 3 17 305 5 0 6 0 -6.9 0.1 -6.7 -7.1 03/21/2005 18:10:00 16 1.2 18.3 12.2 15.8 1.3 18.3 11.8 0.4 0 0.4 0.4 20 4 21 305 5 0 5 0 -7 0 -6.9 -7.1 03/21/2005 18:20:00 16 1.3 19.1 13 15.8 1.4 19.1 11.5 0.4 0 0.4 0.4 23 4 23 305 5 0 5 0 -7.1 0 -6.9 -7.3 03/21/2005 18:30:00 16.3 1.5 19.1 11.8 15.9 1.5 19.1 11.1 0.4 0 0.4 0.4 25 5 23 305 5 0 5 0 -7.1 0 -6.9 -7.3 03/21/2005 18:40:00 16.4 1.3 18.7 12.6 16.1 1.3 19.1 12.2 0.4 0 0.4 0.4 24 4 25 305 4 0 5 0 -7 0 -6.9 -7.1 03/21/2005 18:50:00 16.7 1.3 19.5 13 16.4 1.3 19.1 13 0.4 0 0.4 0.4 30 5 29 305 4 0 4 0 -7.1 0 -6.9 -7.1 03/21/2005 19:00:00 15.8 1.1 18.3 12.2 15.4 1.3 17.9 11.8 0.4 0 0.4 0.4 24 4 24 305 4 0 4 0 -7.1 0 -6.9 -7.1 03/21/2005 19:10:00 16.1 1.5 19.1 11.5 15.8 1.5 18.7 10.7 0.4 0 0.4 0.4 27 5 28 305 4 0 4 0 -7.1 0 -6.9 -7.3 03/21/2005 19:20:00 16 1.3 18.7 12.2 15.7 1.3 18.7 12.6 0.4 0 0.4 0.4 25 5 30 305 4 0 4 0 -7.1 0 -6.9 -7.3 03/21/2005 19:30:00 15.3 1.5 18.3 11.1 15 1.5 18.7 10.3 0.4 0 0.4 0.4 21 5 23 305 4 0 4 0 -6.9 0 -6.9 -7.1 03/21/2005 19:40:00 14.9 1.4 17.6 10.3 14.6 1.6 17.6 9.9 0.4 0 0.4 0.4 19 5 17 305 4 0 4 0 -6.9 0 -6.7 -7.1 03/21/2005 19:50:00 15 1.3 18.3 11.8 14.8 1.4 18.3 11.5 0.4 0 0.4 0.4 19 5 16 305 4 0 4 0 -6.8 0 -6.7 -6.9 03/21/2005 20:00:00 15.2 1.3 17.9 11.5 14.9 1.5 17.9 10.7 0.4 0 0.4 0.4 18 5 23 305 4 0 4 0 -6.8 0 -6.7 -6.9 03/21/2005 20:10:00 15.6 1.2 18.7 12.2 15.4 1.2 19.1 12.2 0.4 0 0.4 0.4 16 4 21 305 4 0 4 0 -6.9 0 -6.7 -7.1 03/21/2005 20:20:00 15.8 1.3 18.7 11.8 15.6 1.3 18.7 12.2 0.4 0 0.4 0.4 17 4 17 305 4 0 4 0 -7 0 -6.9 -7.1 03/21/2005 20:30:00 15.3 1.4 18.3 11.1 15.2 1.4 18.3 11.1 0.4 0 0.4 0.4 17 4 24 305 4 0 4 0 -7.1 0 -6.9 -7.3 03/21/2005 20:40:00 15.7 1.3 19.5 12.6 15.4 1.3 19.5 12.2 0.4 0 0.4 0.4 15 4 18 305 4 0 5 0 -7.3 0 -7.1 -7.5 03/21/2005 20:50:00 15.6 1.7 18.7 11.1 15.3 1.7 19.1 10.7 0.4 0 0.4 0.4 13 5 12 305 5 0 5 0 -7.6 0 -7.3 -7.7 03/21/2005 21:00:00 15.2 1.5 18.7 11.1 15 1.5 18.7 11.5 0.4 0 0.4 0.4 18 5 18 305 5 0 5 0 -7.6 0 -7.3 -7.7 03/21/2005 21:10:00 15.8 1.7 19.5 11.5 15.4 1.7 19.5 11.5 0.4 0 0.4 0.4 15 4 12 305 5 0 5 0 -7.7 0 -7.7 -7.9 03/21/2005 21:20:00 17.7 1.5 21.4 13.3 17.4 1.7 21 12.6 0.4 0 0.4 0.4 15 4 14 305 5 0 6 0 -7.9 0 -7.7 -8.2 03/21/2005 21:30:00 17.4 1.5 20.2 13 17 1.5 20.2 12.6 0.4 0 0.4 0.4 14 4 12 305 6 0 6 0 -7.9 0 -7.7 -8.2 03/21/2005 21:40:00 16 1.6 19.5 12.2 15.6 1.6 19.5 12.2 0.4 0 0.4 0.4 16 5 9 305 7 0 7 0 -8 0 -7.7 -8.2 03/21/2005 21:50:00 18.9 2.1 22.6 12.6 18.5 2 23.3 12.2 0.4 0 0.4 0.4 18 4 18 305 8 0 8 0 -8 0.1 -7.7 -8.2 03/21/2005 22:00:00 20.1 1.6 23.7 14.9 19.6 1.7 23.3 13.7 0.4 0 0.4 0.4 18 3 14 305 9 0 8 0 -8 0.1 -7.7 -8.2 03/21/2005 22:10:00 17.5 2 22.6 13.3 17 2 22.6 13 0.4 0 0.4 0.4 18 5 18 305 9 0 9 0 -8.2 0 -7.9 -8.2 03/21/2005 22:20:00 17.3 1.6 21 13.3 16.9 1.7 21 13.3 0.4 0 0.4 0.4 20 5 21 305 10 0 10 0 -8.2 0 -8.2 -8.4 03/21/2005 22:30:00 15.5 1.7 19.1 10.3 15.2 1.8 19.9 9.9 0.4 0 0.4 0.4 16 5 13 305 11 0 11 0 -8.3 0 -8.2 -8.4 03/21/2005 22:40:00 16.9 1.5 20.2 13 16.6 1.7 20.6 12.6 0.4 0 0.4 0.4 15 4 8 305 11 0 11 0 -8.4 0 -8.4 -8.6 03/21/2005 22:50:00 16.1 1.2 19.1 13 15.8 1.4 19.1 12.2 0.4 0 0.4 0.4 15 5 21 305 11 0 11 0 -8.4 0 -8.2 -8.8 03/21/2005 23:00:00 16.7 1.6 20.2 13 16.5 1.6 20.6 11.8 0.4 0 0.4 0.4 15 4 17 305 12 0 12 0 -8.2 0 -8.2 -8.4 03/21/2005 23:10:00 15.8 1.5 19.1 11.8 15.5 1.6 19.5 11.1 0.4 0 0.4 0.4 14 5 16 305 12 0 12 0 -8.3 0 -8.2 -8.6 03/21/2005 23:20:00 16.7 1.6 19.5 11.8 16.4 1.7 19.5 10.3 0.4 0 0.4 0.4 16 5 16 305 12 0 12 0 -8.3 0 -8.2 -8.6 03/21/2005 23:30:00 16.9 2 21.8 11.8 16.6 2 21.8 12.2 0.4 0 0.4 0.4 19 5 20 305 13 0 13 0 -8.3 0 -8.2 -8.4 03/21/2005 23:40:00 16.6 1.8 20.6 12.2 16.3 1.8 20.2 11.8 0.4 0 0.4 0.4 21 5 18 305 13 0 13 0 -8.4 0 -8.2 -8.6 03/21/2005 23:50:00 15.7 1.6 19.5 11.5 15.5 1.6 19.5 11.5 0.4 0 0.4 0.4 17 5 21 305 13 0 13 0 -8.5 0 -8.2 -8.8 03/22/2005 00:00:00 16.1 1.5 19.9 12.2 15.8 1.5 18.7 12.6 0.4 0 0.4 0.4 15 4 13 305 14 0 13 0 -8.4 0 -7.9 -8.6 03/22/2005 00:10:00 15.9 1.7 19.1 10.7 15.5 1.7 19.1 9.9 0.4 0 0.4 0.4 16 5 12 305 14 0 14 0 -8.5 0 -8.2 -8.6 03/22/2005 00:20:00 15.9 1.3 19.1 12.2 15.6 1.3 19.1 10.7 0.4 0 0.4 0.4 17 4 16 305 14 0 14 0 -8.3 0 -8.2 -8.4 03/22/2005 00:30:00 16.9 1.4 19.9 12.6 16.5 1.5 20.6 13 0.4 0 0.4 0.4 15 4 16 305 14 0 14 0 -8.4 0 -8.2 -8.6 03/22/2005 00:40:00 15.6 1.4 18.3 11.8 15.3 1.5 18.7 11.5 0.4 0 0.4 0.4 16 4 22 305 14 0 14 0 -8.4 0 -8.4 -8.6 03/22/2005 00:50:00 14.6 1.5 17.9 10.7 14.3 1.6 17.9 9.5 0.4 0 0.4 0.4 17 5 22 305 15 0 14 0 -8.5 0 -8.4 -8.6 03/22/2005 01:00:00 15.7 1.5 19.1 11.5 15.4 1.5 19.1 10.7 0.4 0 0.4 0.4 15 4 21 305 15 0 15 0 -8.5 0 -8.4 -8.8 03/22/2005 01:10:00 16 1.5 19.5 12.6 15.7 1.5 19.1 12.2 0.4 0 0.4 0.4 14 4 17 305 15 0 15 0 -8.6 0 -8.4 -8.8 03/22/2005 01:20:00 15 1.3 18.3 11.1 14.8 1.3 17.6 11.1 0.4 0 0.4 0.4 12 4 13 305 15 0 15 0 -8.7 0 -8.4 -8.8 03/22/2005 01:30:00 15.6 1.5 18.3 10.7 15.3 1.5 18.7 11.1 0.4 0 0.4 0.4 10 5 6 305 15 0 15 0 -8.8 0 -8.6 -9 03/22/2005 01:40:00 15.8 1.3 18.7 11.8 15.4 1.3 17.9 11.8 0.4 0 0.4 0.4 14 4 13 305 15 0 15 0 -8.8 0 -8.6 -8.8 03/22/2005 01:50:00 15.2 1.5 18.7 11.1 14.9 1.6 19.1 10.7 0.4 0 0.4 0.4 16 5 11 305 15 0 15 0 -8.9 0 -8.8 -9.2 03/22/2005 02:00:00 15.3 1.6 18.3 11.1 14.9 1.7 18.3 10.3 0.4 0 0.4 0.4 13 5 15 305 15 0 15 0 -9.1 0.1 -8.8 -9.2 03/22/2005 02:10:00 17 1.6 19.9 12.2 16.5 1.5 19.5 12.2 0.4 0 0.4 0.4 14 4 10 305 15 0 15 0 -9.1 0 -9 -9.2 03/22/2005 02:20:00 17 1.5 19.5 10.7 16.6 1.6 19.5 11.1 0.4 0 0.4 0.4 13 4 11 305 15 0 15 0 -9 0 -8.8 -9.2 03/22/2005 02:30:00 16.1 1.4 18.7 12.2 15.7 1.5 18.7 12.2 0.4 0 0.4 0.4 15 5 17 305 15 0 15 0 -9 0 -8.8 -9.2 03/22/2005 02:40:00 16.4 1.7 19.1 12.6 16.1 1.7 19.5 12.2 0.4 0 0.4 0.4 11 5 10 305 15 0 15 0 -9 0 -8.8 -9.2 03/22/2005 02:50:00 16.6 1.6 19.5 11.1 16.2 1.7 19.1 11.5 0.4 0 0.4 0.4 12 4 12 305 15 0 15 0 -8.8 0 -8.6 -9 03/22/2005 03:00:00 16.4 1.4 19.5 12.6 16 1.4 19.1 11.8 0.4 0 0.4 0.4 11 4 14 305 15 0 15 0 -9 0 -8.8 -9.2 03/22/2005 03:10:00 16 1.6 19.1 11.1 15.6 1.7 19.1 11.5 0.4 0 0.4 0.4 11 4 11 305 16 0 15 0 -8.9 0 -8.8 -9.2 03/22/2005 03:20:00 15.8 1.8 19.9 10.7 15.5 1.8 19.9 10.3 0.4 0 0.4 0.4 12 5 9 305 16 0 15 0 -8.9 0 -8.8 -9.2 03/22/2005 03:30:00 16.9 1.1 19.5 13.3 16.7 1.3 19.5 13.3 0.4 0 0.4 0.4 11 3 12 305 16 0 16 0 -9 0 -8.8 -9.2 03/22/2005 03:40:00 15.2 1.7 19.1 11.5 15 1.7 19.5 10.7 0.4 0 0.4 0.4 9 5 10 305 16 0 16 0 -8.8 0 -8.8 -9 03/22/2005 03:50:00 16.1 1.5 19.1 12.2 15.9 1.6 19.1 11.8 0.4 0 0.4 0.4 10 5 9 305 16 0 16 0 -9 0 -8.8 -9.2 03/22/2005 04:00:00 15.8 1.4 19.1 12.2 15.6 1.4 19.1 12.2 0.4 0 0.4 0.4 12 5 10 305 16 0 16 0 -9.1 0 -9 -9.2 03/22/2005 04:10:00 15.6 1.5 19.1 12.2 15.5 1.5 18.7 11.8 0.4 0 0.4 0.4 11 5 8 305 16 0 15 0 -9.3 0 -9.2 -9.4 03/22/2005 04:20:00 16.4 1.4 19.1 11.8 16.1 1.5 19.5 11.5 0.4 0 0.4 0.4 11 4 12 305 16 0 15 0 -9.3 0 -9.2 -9.4 03/22/2005 04:30:00 17 1.7 20.2 11.1 16.6 1.7 20.2 11.8 0.4 0 0.4 0.4 13 4 15 305 15 0 15 0 -9.3 0 -9.2 -9.6 03/22/2005 04:40:00 16.2 1.5 19.1 12.2 15.8 1.5 19.1 11.8 0.4 0 0.4 0.4 14 6 10 305 16 0 15 0 -9.3 0 -9.2 -9.4 03/22/2005 04:50:00 15.9 2 19.1 9.9 15.5 2 18.7 10.7 0.4 0 0.4 0.4 16 6 21 305 15 0 15 0 -9.4 0 -9.2 -9.6 03/22/2005 05:00:00 16.8 2.2 21 10.3 16.4 2.1 20.6 11.1 0.4 0 0.4 0.4 14 5 11 305 15 0 15 0 -9.4 0 -9.2 -9.6 03/22/2005 05:10:00 15.4 1.9 20.2 11.5 15.2 1.9 19.9 10.7 0.4 0 0.4 0.4 14 6 22 305 15 0 15 0 -9.4 0 -9.2 -9.6 03/22/2005 05:20:00 15.6 1.9 19.9 11.8 15.4 1.8 19.9 11.1 0.4 0 0.4 0.4 12 6 14 305 15 0 15 0 -9.5 0 -9.2 -9.6 03/22/2005 05:30:00 16.6 1.7 20.2 11.8 16.2 1.7 20.2 11.5 0.4 0 0.4 0.4 17 5 16 305 15 0 15 0 -9.5 0 -9.2 -9.8 03/22/2005 05:40:00 16.9 1.3 20.2 12.6 16.6 1.4 19.5 12.6 0.4 0 0.4 0.4 15 4 12 305 15 0 15 0 -9.4 0 -9.2 -9.6 03/22/2005 05:50:00 15.8 1.5 19.5 11.5 15.4 1.5 18.7 11.8 0.4 0 0.4 0.4 13 5 9 305 15 0 15 0 -9.5 0 -9.2 -9.6 03/22/2005 06:00:00 16.4 1.3 19.5 12.2 16.2 1.3 19.1 12.6 0.4 0 0.4 0.4 13 4 18 305 15 0 15 0 -9.3 0 -9.2 -9.4 03/22/2005 06:10:00 15.7 1.7 19.5 11.8 15.4 1.9 19.1 11.1 0.4 0 0.4 0.4 16 5 12 305 14 0 14 0 -9.4 0 -9.2 -9.6 03/22/2005 06:20:00 16.2 1.6 19.9 12.6 16 1.7 20.2 12.6 0.4 0 0.4 0.4 13 4 16 305 14 0 14 0 -9.6 0.1 -9.2 -9.8 03/22/2005 06:30:00 17.5 1.5 21 13.3 17.1 1.5 21.4 13.7 0.4 0 0.4 0.4 15 4 13 305 14 0 14 0 -9.7 0 -9.6 -9.8 03/22/2005 06:40:00 16.7 1.6 19.9 12.6 16.3 1.7 20.6 12.2 0.4 0 0.4 0.4 19 4 15 305 14 0 14 0 -9.8 0 -9.6 -9.8 03/22/2005 06:50:00 17.4 1.3 20.6 13.7 17.2 1.4 20.6 13.7 0.4 0 0.4 0.4 17 5 13 305 13 0 13 0 -9.8 0 -9.6 -9.8 03/22/2005 07:00:00 17.1 1.6 20.6 12.6 16.7 1.7 20.6 12.6 0.4 0 0.4 0.4 17 5 13 305 13 0 13 0 -9.9 0 -9.8 -10 03/22/2005 07:10:00 16.9 1.5 20.2 13.3 16.4 1.6 20.2 12.2 0.4 0 0.4 0.4 18 5 19 305 12 0 12 0 -10 0 -9.8 -10.2 03/22/2005 07:20:00 15.6 1.8 19.1 11.1 15.3 1.7 19.1 11.5 0.4 0 0.4 0.4 17 5 14 305 11 0 11 0 -10 0 -9.8 -10.2 03/22/2005 07:30:00 15.9 2.3 21.4 11.5 15.6 2.2 20.2 10.7 0.4 0 0.4 0.4 18 5 19 305 11 0 11 0 -10 0 -9.8 -10.2 03/22/2005 07:40:00 15.6 1.9 20.2 11.8 15.2 1.9 20.6 11.5 0.4 0 0.4 0.4 19 6 19 305 10 0 10 0 -10.1 0 -10 -10.2 03/22/2005 07:50:00 15.6 1.9 20.2 10.3 15.3 1.9 19.9 9.9 0.4 0 0.4 0.4 17 5 20 305 10 0 10 0 -10.1 0 -9.8 -10.2 03/22/2005 08:00:00 15.7 1.8 19.5 10.7 15.4 1.8 19.5 10.7 0.4 0 0.4 0.4 17 5 18 305 10 0 9 0 -10.1 0 -9.8 -10.4 03/22/2005 08:10:00 16 1.3 19.1 11.5 15.6 1.3 18.7 10.7 0.4 0 0.4 0.4 13 5 21 305 9 0 9 0 -10 0 -9.8 -10.2 03/22/2005 08:20:00 17.2 1.5 20.2 13 16.9 1.6 20.2 13.3 0.4 0 0.4 0.4 15 5 8 305 9 0 9 0 -10.1 0.1 -9.8 -10.4 03/22/2005 08:30:00 17 1.7 21 12.6 16.7 1.7 20.2 11.8 0.4 0 0.4 0.4 14 5 15 305 9 0 9 0 -10.4 0 -10 -10.4 03/22/2005 08:40:00 16.9 1.5 19.9 13.3 16.5 1.6 19.5 12.2 0.4 0 0.4 0.4 15 5 11 305 9 0 9 0 -10.4 0 -10.2 -10.7 03/22/2005 08:50:00 16.1 1.7 19.9 11.5 15.8 1.7 19.9 11.1 0.4 0 0.4 0.4 16 5 14 305 9 0 9 0 -10.3 0 -10 -10.4 03/22/2005 09:00:00 16.1 1.6 19.5 11.5 15.9 1.6 19.5 11.8 0.4 0 0.4 0.4 13 5 15 305 9 0 9 0 -10.4 0 -10.4 -10.7 03/22/2005 09:10:00 17.2 1.5 20.6 13.3 16.9 1.6 20.6 12.6 0.4 0 0.4 0.4 15 4 13 305 9 0 9 0 -10.5 0 -10.4 -10.9 03/22/2005 09:20:00 17.2 1.5 20.2 11.8 16.9 1.6 19.9 11.5 0.4 0 0.4 0.4 15 4 9 305 9 0 9 0 -10.5 0 -10.4 -10.9 03/22/2005 09:30:00 17.2 1.5 20.6 13.7 16.9 1.5 21 13.3 0.4 0 0.4 0.4 15 4 18 305 9 0 9 0 -10.5 0 -10.4 -10.7 03/22/2005 09:40:00 16.4 1.5 19.9 12.6 16.1 1.5 20.2 11.8 0.4 0 0.4 0.4 16 5 13 305 9 0 9 0 -10.4 0 -10.2 -10.7 03/22/2005 09:50:00 16.2 1.6 19.5 11.8 15.9 1.6 19.5 11.5 0.4 0 0.4 0.4 17 5 18 305 9 0 9 0 -10.5 0.1 -10.4 -10.9 03/22/2005 10:00:00 16.1 1.5 18.7 11.1 15.9 1.4 18.7 11.8 0.4 0 0.4 0.4 15 5 21 305 9 0 9 0 -10.6 0 -10.4 -10.9 03/22/2005 10:10:00 15.6 1.9 18.7 9.9 15.4 2 18.3 10.3 0.4 0 0.4 0.4 17 5 16 305 9 0 9 0 -10.5 0 -10.4 -10.9 03/22/2005 10:20:00 15.2 1.8 18.7 10.7 15 1.9 19.1 11.1 0.4 0 0.4 0.4 17 5 19 305 9 0 9 0 -10.4 0 -10.2 -10.7 03/22/2005 10:30:00 16 1.5 19.1 11.5 15.8 1.5 19.1 10.7 0.4 0 0.4 0.4 15 5 15 305 8 0 8 0 -10.5 0 -10.2 -10.7 03/22/2005 10:40:00 15.7 1.5 18.7 11.1 15.5 1.5 18.3 11.1 0.4 0 0.4 0.4 18 5 18 305 8 0 8 0 -10.4 0 -10.2 -10.4 03/22/2005 10:50:00 14.5 1.7 17.6 10.7 14.3 1.6 17.6 10.3 0.4 0 0.4 0.4 19 5 16 305 8 0 8 0 -10.3 0 -10 -10.4 03/22/2005 11:00:00 15.1 1.3 17.9 12.2 14.9 1.3 18.3 11.1 0.4 0 0.4 0.4 15 5 14 305 8 0 8 0 -10.3 0 -10 -10.4 03/22/2005 11:10:00 13.7 1.4 17.2 10.3 13.6 1.4 17.2 9.1 0.4 0 0.4 0.4 17 5 25 305 8 0 8 0 -10.2 0 -10 -10.4 03/22/2005 11:20:00 14.2 1.5 16.8 10.3 14.1 1.5 17.6 10.3 0.4 0 0.4 0.4 17 5 13 305 8 0 8 0 -10.2 0 -10 -10.4 03/22/2005 11:30:00 14.7 1.1 17.2 11.5 14.6 1.2 17.2 10.7 0.4 0 0.4 0.4 17 5 10 305 7 0 7 0 -10.2 0 -10 -10.4 03/22/2005 11:40:00 13.5 1.3 16.4 9.9 13.3 1.3 16.4 9.1 0.4 0 0.4 0.4 17 5 17 305 7 0 7 0 -10.2 0 -9.8 -10.4 03/22/2005 11:50:00 13.2 1.5 16.4 9.1 13.1 1.5 16.8 9.5 0.4 0 0.4 0.4 17 5 21 305 7 0 7 0 -10.1 0 -9.8 -10.2 03/22/2005 12:00:00 13.8 1.2 16.1 9.9 13.6 1.2 16.4 9.5 0.4 0 0.4 0.4 16 5 20 305 7 0 7 0 -10.1 0 -9.8 -10.2 03/22/2005 12:10:00 13.5 1.7 16.8 9.5 13.4 1.7 16.8 8.8 0.4 0 0.4 0.4 18 5 11 305 7 0 7 0 -10.2 0 -9.8 -10.4 03/22/2005 12:20:00 14.2 1.3 17.2 10.3 14.1 1.3 17.6 10.3 0.4 0 0.4 0.4 16 5 15 305 7 0 7 0 -10.1 0 -9.8 -10.2 03/22/2005 12:30:00 13.7 1.5 17.2 9.9 13.6 1.5 17.6 9.5 0.4 0 0.4 0.4 19 5 16 305 7 0 7 0 -10 0 -9.8 -10.2 03/22/2005 12:40:00 15.1 1.2 17.2 11.8 15 1.3 17.6 11.1 0.4 0 0.4 0.4 15 5 16 305 7 0 7 0 -10.2 0 -10 -10.4 03/22/2005 12:50:00 13.3 1.3 16.4 10.3 13.2 1.3 16.4 9.5 0.4 0 0.4 0.4 19 5 18 305 7 0 7 0 -10.1 0 -9.8 -10.4 03/22/2005 13:00:00 13.6 1.5 16.4 9.9 13.5 1.5 16.8 9.5 0.4 0 0.4 0.4 18 4 14 305 7 0 7 0 -10 0 -9.8 -10.2 03/22/2005 13:10:00 13.4 1.3 17.2 9.9 13.2 1.3 17.6 9.5 0.4 0 0.4 0.4 20 5 19 305 7 0 7 0 -9.9 0 -9.6 -10 03/22/2005 13:20:00 13.9 1 16.1 10.7 13.8 1 16.1 10.7 0.4 0 0.4 0.4 20 5 21 305 7 0 7 0 -10 0 -9.8 -10 03/22/2005 13:30:00 13.6 1.3 16.4 9.9 13.4 1.4 16.8 9.9 0.4 0 0.4 0.4 21 5 23 305 9 0 8 0 -9.8 0 -9.6 -9.8 03/22/2005 13:40:00 13.9 1.1 16.8 11.1 13.7 1.2 16.4 9.9 0.4 0 0.4 0.4 19 5 14 305 9 0 9 0 -9.9 0 -9.6 -10 03/22/2005 13:50:00 13 1.3 15.6 9.1 12.9 1.3 16.1 9.5 0.4 0 0.4 0.4 17 5 16 305 11 0 11 0 -9.8 0 -9.4 -10 03/22/2005 14:00:00 12 1.2 14.9 9.1 12 1.2 15.3 8.8 0.4 0 0.4 0.4 22 6 23 305 12 0 13 0 -9.6 0 -9.2 -9.8 03/22/2005 14:10:00 12.4 1 14.5 9.5 12.2 1 14.1 9.5 0.4 0 0.4 0.4 25 5 31 305 13 0 13 0 -9.5 0 -9.2 -9.6 03/22/2005 14:20:00 12.6 1 14.9 9.1 12.4 1 14.9 9.9 0.4 0 0.4 0.4 23 5 29 305 14 0 14 0 -9.4 0 -9.2 -9.6 03/22/2005 14:30:00 12.4 1 14.5 9.1 12.3 1 14.5 8.8 0.4 0 0.4 0.4 22 6 23 305 14 0 14 0 -9.4 0 -9.2 -9.6 03/22/2005 14:40:00 11.9 1.7 15.6 8 11.7 1.7 15.3 8.4 0.4 0 0.4 0.4 20 6 21 305 15 0 14 0 -9.3 0.1 -8.8 -9.6 03/22/2005 14:50:00 11.5 1.2 13.7 7.6 11.3 1.3 14.1 7.6 0.4 0 0.4 0.4 27 5 25 305 15 0 15 0 -9.1 0.1 -8.8 -9.2 03/22/2005 15:00:00 11.5 1 13.7 8.8 11.3 1 13.7 8.4 0.4 0 0.4 0.4 31 6 33 305 16 0 16 0 -8.9 0.1 -8.6 -9.2 03/22/2005 15:10:00 11.3 1.1 13.7 8 11.1 1.1 13.7 8 0.4 0 0.4 0.4 31 5 31 305 17 0 17 0 -8.8 0 -8.4 -9 03/22/2005 15:20:00 12 0.8 13.7 9.1 11.8 0.9 13.7 9.1 0.4 0 0.4 0.4 40 5 32 305 18 0 18 0 -8.7 0 -8.4 -8.8 03/22/2005 15:30:00 12.4 1 14.9 9.5 12.2 1 14.1 9.1 0.4 0 0.4 0.4 34 5 37 305 19 0 19 0 -8.6 0.1 -8.4 -8.8 03/22/2005 15:40:00 12.1 1.2 14.9 8.8 12 1.2 14.9 8.8 0.4 0 0.4 0.4 34 5 41 305 19 0 19 0 -8.7 0 -8.4 -8.8 03/22/2005 15:50:00 12.1 1 14.5 8.8 11.9 1 14.1 8.8 0.4 0 0.4 0.4 31 5 36 305 19 0 19 0 -8.7 0 -8.6 -8.8 03/22/2005 16:00:00 12.2 1.3 15.3 8.8 11.9 1.3 14.5 8.8 0.4 0 0.4 0.4 28 6 30 305 19 0 20 0 -8.7 0 -8.6 -9 03/22/2005 16:10:00 12.4 1.1 14.9 9.1 12.2 1.2 14.9 9.1 0.4 0 0.4 0.4 33 5 29 305 20 0 20 0 -8.9 0 -8.6 -9.2 03/22/2005 16:20:00 11.8 1.2 14.5 8.4 11.7 1.3 14.1 8.4 0.4 0 0.4 0.4 41 6 36 305 20 0 19 0 -8.9 0 -8.8 -9 03/22/2005 16:30:00 11.2 1.5 14.1 7.2 11 1.5 13.7 6.8 0.4 0 0.4 0.4 43 6 40 305 20 0 20 0 -8.9 0 -8.8 -9.2 03/22/2005 16:40:00 8.7 1.5 12.6 6.1 8.7 1.5 12.2 5.7 0.4 0 0.4 0.4 57 9 40 305 19 0 20 0 -9.1 0.1 -8.8 -9.2 03/22/2005 16:50:00 8.3 1.2 10.7 5.7 8.1 1.1 10.7 5.3 0.4 0 0.4 0.4 52 7 44 305 20 0 20 0 -9.1 0.1 -8.8 -9.2 03/22/2005 17:00:00 7.5 0.8 9.1 5.3 7.4 0.8 9.1 5.7 0.4 0 0.4 0.4 46 4 50 305 21 1 20 0 -8.9 0.3 -8.4 -9.2 03/22/2005 17:10:00 7.8 0.7 9.1 5.7 7.7 0.8 9.5 6.1 0.4 0 0.4 0.4 46 5 47 305 24 1 25 0 -8.4 0 -8.2 -8.6 03/22/2005 17:20:00 7.6 0.7 9.5 6.1 7.5 0.7 9.9 5.7 0.4 0 0.4 0.4 49 5 56 305 27 1 29 0 -8.2 0 -7.9 -8.4 03/22/2005 17:30:00 8 0.7 9.5 6.1 8 0.7 9.9 6.1 0.4 0 0.4 0.4 52 7 62 305 29 0 29 0 -8.2 0.1 -7.7 -8.6 03/22/2005 17:40:00 8.2 1 10.7 5.7 8.1 1.1 10.3 5.7 0.4 0 0.4 0.4 50 5 53 305 29 0 29 0 -8.4 0.1 -8.2 -8.8 03/22/2005 17:50:00 8.5 0.7 9.9 6.5 8.4 0.7 10.3 6.1 0.4 0 0.4 0.4 54 4 50 305 27 1 27 0 -8.6 0 -8.4 -8.8 03/22/2005 18:00:00 7.4 0.9 9.5 4.9 7.4 0.9 9.5 5.3 0.4 0 0.4 0.4 49 7 59 305 26 0 26 0 -8.5 0 -8.4 -8.8 03/22/2005 18:10:00 8.6 0.8 10.3 6.5 8.4 0.8 10.3 6.1 0.4 0 0.4 0.4 43 6 44 305 24 0 25 0 -8.7 0 -8.6 -9 03/22/2005 18:20:00 8.8 0.7 10.7 6.8 8.8 0.8 11.1 6.8 0.4 0 0.4 0.4 40 5 41 305 23 0 23 0 -8.9 0 -8.8 -9.2 03/22/2005 18:30:00 7.9 0.9 9.9 5.7 7.9 1 9.9 4.9 0.4 0 0.4 0.4 45 5 42 305 23 0 22 0 -9 0 -8.8 -9.2 03/22/2005 18:40:00 7.3 0.7 9.1 5.7 7.4 0.7 9.5 5.7 0.4 0 0.4 0.4 54 6 50 305 22 0 22 0 -8.9 0 -8.8 -9.2 03/22/2005 18:50:00 6.5 1 8.8 4.2 6.6 1 9.1 4.6 0.4 0 0.4 0.4 59 7 53 305 22 0 22 0 -9 0 -8.8 -9.2 03/22/2005 19:00:00 6.6 1 9.1 4.6 6.6 1 9.1 4.6 0.4 0 0.4 0.4 60 6 53 305 22 0 22 0 -9.1 0.1 -8.8 -9.2 03/22/2005 19:10:00 5.5 0.5 7.2 4.2 5.4 0.5 6.8 4.6 0.4 0 0.4 0.4 66 5 66 305 21 0 21 0 -9.6 0.1 -9.2 -9.8 03/22/2005 19:20:00 6.2 0.5 7.2 4.9 6.2 0.5 7.2 4.9 0.4 0 0.4 0.4 63 3 65 305 21 0 21 0 -9.6 0.1 -9.4 -9.8 03/22/2005 19:30:00 6 0.5 7.2 4.9 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 59 4 52 305 21 0 20 0 -9.8 0 -9.6 -10 03/22/2005 19:40:00 6.3 0.5 8 4.9 6.2 0.5 8 4.9 0.4 0 0.4 0.4 59 5 60 305 20 0 20 0 -9.8 0 -9.6 -10 03/22/2005 19:50:00 6.3 0.5 8 4.9 6.1 0.6 8.4 5.3 0.4 0 0.4 0.4 62 5 54 305 20 0 20 0 -9.8 0 -9.6 -10 03/22/2005 20:00:00 6 0.5 7.6 4.9 5.8 0.4 7.2 4.6 0.4 0 0.4 0.4 60 5 59 305 19 0 19 0 -9.9 0 -9.6 -10 03/22/2005 20:10:00 5.5 0.6 6.8 3.8 5.4 0.5 6.8 3.8 0.4 0 0.4 0.4 58 5 57 305 19 0 19 0 -9.8 0 -9.6 -10 03/22/2005 20:20:00 5.8 0.5 7.2 4.6 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 66 5 62 305 19 0 19 0 -10.1 0 -9.8 -10.2 03/22/2005 20:30:00 6.2 0.5 7.6 4.9 5.9 0.5 7.2 4.9 0.4 0 0.4 0.4 66 5 69 305 18 0 19 0 -10 0 -9.8 -10.2 03/22/2005 20:40:00 6.3 0.4 7.2 5.3 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 68 3 68 305 19 0 18 0 -9.8 0 -9.6 -10 03/22/2005 20:50:00 6 0.8 8.4 3.8 5.7 0.8 8 3.8 0.4 0 0.4 0.4 63 5 63 305 18 0 18 0 -10 0 -9.6 -10.2 03/22/2005 21:00:00 5.7 0.6 7.2 4.2 5.5 0.7 7.2 4.2 0.4 0 0.4 0.4 60 5 68 305 18 0 18 0 -10.1 0.1 -9.8 -10.4 03/22/2005 21:10:00 5.8 0.6 7.2 4.2 5.6 0.7 7.2 3.8 0.4 0 0.4 0.4 56 6 58 305 18 0 18 0 -10.1 0 -10 -10.4 03/22/2005 21:20:00 5.7 0.5 6.8 4.2 5.5 0.4 6.8 4.2 0.4 0 0.4 0.4 61 4 60 305 18 0 18 0 -10.1 0 -10 -10.2 03/22/2005 21:30:00 5.7 0.6 7.2 4.2 5.4 0.6 7.2 3.8 0.4 0 0.4 0.4 60 5 68 305 17 0 18 0 -10 0 -9.8 -10.2 03/22/2005 21:40:00 4.9 0.7 7.2 3.4 4.8 0.7 7.2 3 0.4 0 0.4 0.4 55 6 53 305 17 0 18 0 -9.9 0 -9.8 -10 03/22/2005 21:50:00 4.9 0.7 6.5 3.4 4.8 0.6 6.5 3.4 0.4 0 0.4 0.4 51 7 43 305 17 0 17 0 -9.9 0 -9.6 -10 03/22/2005 22:00:00 5 0.9 7.2 3 4.7 0.8 6.5 3 0.4 0 0.4 0.4 54 6 53 305 17 0 17 0 -9.8 0 -9.6 -10 03/22/2005 22:10:00 5.7 0.9 8 3.4 5.6 1 8 3.4 0.4 0 0.4 0.4 55 7 61 305 17 0 18 0 -9.7 0.1 -9.2 -10 03/22/2005 22:20:00 5.2 0.7 7.2 2.6 5 0.7 6.8 3 0.4 0 0.4 0.4 54 8 46 305 18 0 18 0 -9.6 0.1 -9.2 -9.8 03/22/2005 22:30:00 5.2 0.5 7.2 3.8 5 0.5 6.5 3.8 0.4 0 0.4 0.4 55 7 41 305 18 0 18 0 -9.9 0 -9.6 -10.2 03/22/2005 22:40:00 5.5 0.8 8 3.8 5.4 0.8 8 3.8 0.4 0 0.4 0.4 56 7 59 305 17 0 18 0 -9.8 0.1 -9.6 -10.2 03/22/2005 22:50:00 5.8 0.6 7.6 4.6 5.6 0.6 7.6 4.6 0.4 0 0.4 0.4 59 6 62 305 17 0 17 0 -9.8 0 -9.4 -10 03/22/2005 23:00:00 6 1 8.4 4.2 5.8 1.1 8.8 3.8 0.4 0 0.4 0.4 56 7 56 305 17 0 18 0 -9.7 0 -9.4 -9.8 03/22/2005 23:10:00 6.1 1.1 8.8 3.8 6 1.1 8.8 3.8 0.4 0 0.4 0.4 58 6 66 305 18 0 18 0 -9.4 0 -9.2 -9.6 03/22/2005 23:20:00 6.5 0.7 8.4 4.9 6.4 0.7 8.4 4.6 0.4 0 0.4 0.4 59 7 50 305 18 0 18 0 -9.3 0.1 -9.2 -9.6 03/22/2005 23:30:00 5.4 0.7 7.2 3.8 5.2 0.7 7.6 3.8 0.4 0 0.4 0.4 59 7 49 305 18 0 18 0 -9.6 0.1 -9.2 -9.8 03/22/2005 23:40:00 5.2 0.6 6.8 3.8 5 0.6 6.8 3.4 0.4 0 0.4 0.4 60 8 54 305 17 0 18 0 -9.6 0 -9.4 -9.8 03/22/2005 23:50:00 7.3 0.9 9.5 4.2 7.2 1 9.1 3.8 0.4 0 0.4 0.4 59 5 60 305 18 0 18 0 -9.1 0.2 -8.8 -9.6 03/23/2005 00:00:00 5.8 0.8 8.4 4.2 5.8 0.8 8 4.2 0.4 0 0.4 0.4 57 6 64 305 18 0 18 0 -9.1 0.2 -8.6 -9.6 03/23/2005 00:10:00 5.3 0.5 6.8 4.2 5.1 0.5 7.2 3.8 0.4 0 0.4 0.4 59 5 57 305 17 0 18 0 -9.7 0 -9.4 -9.8 03/23/2005 00:20:00 5.9 0.6 8 4.6 5.8 0.6 7.6 4.2 0.4 0 0.4 0.4 57 6 61 305 17 0 17 0 -9.4 0.1 -9 -9.8 03/23/2005 00:30:00 7.1 1 9.9 4.9 7 1 9.1 4.2 0.4 0 0.4 0.4 44 5 35 305 18 0 18 0 -9 0.1 -8.8 -9.4 03/23/2005 00:40:00 8.2 0.8 9.9 6.5 8 0.8 9.9 6.1 0.4 0 0.4 0.4 40 5 31 305 18 0 18 0 -8.8 0.1 -8.4 -9.2 03/23/2005 00:50:00 7.6 0.5 8.8 6.1 7.3 0.5 8.8 6.1 0.4 0 0.4 0.4 39 4 43 305 18 0 18 0 -9.2 0 -9 -9.4 03/23/2005 01:00:00 7.3 0.7 9.1 5.7 7.1 0.6 9.1 5.3 0.4 0 0.4 0.4 46 7 47 305 18 0 18 0 -9.3 0 -9 -9.4 03/23/2005 01:10:00 7.2 0.8 8.8 5.3 7.1 0.8 8.8 5.7 0.4 0 0.4 0.4 48 6 53 305 18 0 18 0 -9.4 0 -9.2 -9.6 03/23/2005 01:20:00 7.1 0.7 8.8 5.7 7 0.7 8.8 5.3 0.4 0 0.4 0.4 45 7 37 305 18 0 18 0 -9.4 0 -9.2 -9.6 03/23/2005 01:30:00 7.2 0.6 8.4 5.7 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 44 6 50 305 18 0 18 0 -9.5 0 -9.2 -9.6 03/23/2005 01:40:00 7.8 0.6 9.1 6.1 7.7 0.6 9.1 5.7 0.4 0 0.4 0.4 45 5 35 305 18 0 18 0 -9.5 0 -9.2 -9.8 03/23/2005 01:50:00 7.8 0.5 9.1 6.5 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 46 5 44 305 18 0 18 0 -9.6 0 -9.4 -9.8 03/23/2005 02:00:00 7.6 0.6 8.8 6.1 7.5 0.6 8.8 5.7 0.4 0 0.4 0.4 44 4 45 305 18 0 18 0 -9.6 0 -9.4 -9.8 03/23/2005 02:10:00 7.3 0.6 8.8 5.3 7.2 0.7 8.8 5.3 0.4 0 0.4 0.4 40 5 44 305 19 0 19 0 -9.6 0 -9.4 -9.8 03/23/2005 02:20:00 7 0.6 8.4 5.3 7 0.7 8.4 5.3 0.4 0 0.4 0.4 42 4 41 305 19 0 19 0 -9.6 0 -9.4 -9.8 03/23/2005 02:30:00 6.5 0.5 7.6 4.9 6.3 0.5 7.6 4.9 0.4 0 0.4 0.4 39 5 42 305 18 0 19 0 -9.8 0 -9.4 -10 03/23/2005 02:40:00 7.1 0.6 8.8 5.3 6.8 0.7 9.1 4.9 0.4 0 0.4 0.4 38 4 31 305 18 0 18 0 -9.8 0 -9.6 -10 03/23/2005 02:50:00 7.8 0.5 8.8 5.7 7.7 0.5 9.1 5.7 0.4 0 0.4 0.4 35 5 31 305 19 0 18 0 -9.4 0.1 -9.2 -9.8 03/23/2005 03:00:00 8 0.6 9.1 6.5 7.9 0.6 9.5 6.5 0.4 0 0.4 0.4 31 5 27 305 19 0 19 0 -9.5 0 -9.2 -9.6 03/23/2005 03:10:00 7.6 0.6 9.5 6.1 7.6 0.7 9.5 5.7 0.4 0 0.4 0.4 29 6 38 305 19 0 19 0 -9.7 0.1 -9.4 -9.8 03/23/2005 03:20:00 7.3 0.6 9.1 5.3 7.2 0.6 9.1 5.3 0.4 0 0.4 0.4 36 6 36 305 19 0 19 0 -9.9 0 -9.6 -10 03/23/2005 03:30:00 6.7 0.5 8 5.3 6.5 0.6 8 4.9 0.4 0 0.4 0.4 28 4 34 305 19 0 18 0 -9.8 0 -9.6 -10 03/23/2005 03:40:00 6.6 0.6 8 4.9 6.4 0.7 8.4 4.6 0.4 0 0.4 0.4 21 6 26 305 19 0 19 0 -9.8 0 -9.6 -9.8 03/23/2005 03:50:00 7 0.4 8 5.7 7 0.5 8 5.7 0.4 0 0.4 0.4 28 5 22 305 19 0 19 0 -9.8 0 -9.6 -9.8 03/23/2005 04:00:00 7 0.7 8.4 5.3 6.9 0.8 8.8 4.9 0.4 0 0.4 0.4 18 4 22 305 19 0 19 0 -9.7 0 -9.4 -9.8 03/23/2005 04:10:00 7.6 0.6 8.8 5.7 7.6 0.7 9.1 5.7 0.4 0 0.4 0.4 15 5 14 305 19 0 19 0 -9.7 0 -9.4 -9.8 03/23/2005 04:20:00 7.7 0.6 9.1 6.1 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 16 4 15 305 19 0 19 0 -9.8 0 -9.6 -10 03/23/2005 04:30:00 7.7 0.6 8.8 6.1 7.6 0.6 8.8 5.7 0.4 0 0.4 0.4 19 4 17 305 19 0 19 0 -10 0 -9.8 -10 03/23/2005 04:40:00 8.1 0.7 9.9 6.1 8.1 0.6 9.9 6.5 0.4 0 0.4 0.4 16 4 16 305 19 0 19 0 -10.1 0 -9.8 -10.2 03/23/2005 04:50:00 7.4 0.7 9.5 5.7 7.3 0.7 9.5 5.3 0.4 0 0.4 0.4 28 5 21 305 18 0 18 0 -10.1 0 -9.8 -10.2 03/23/2005 05:00:00 7.4 0.5 8.4 5.7 7.4 0.6 9.1 5.7 0.4 0 0.4 0.4 24 5 28 305 18 0 18 0 -10.3 0 -10 -10.4 03/23/2005 05:10:00 7.7 0.6 9.5 6.1 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 19 3 17 305 18 0 18 0 -10.3 0 -10 -10.4 03/23/2005 05:20:00 7.6 0.6 9.1 5.7 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 26 6 27 305 18 0 18 0 -10.3 0 -10 -10.4 03/23/2005 05:30:00 8 0.7 9.5 5.7 8 0.7 9.5 6.1 0.4 0 0.4 0.4 27 5 33 305 18 0 18 0 -10.3 0 -10 -10.4 03/23/2005 05:40:00 7.5 0.7 9.5 5.3 7.4 0.8 9.1 5.3 0.4 0 0.4 0.4 31 9 12 305 18 0 18 0 -10.3 0 -10 -10.4 03/23/2005 05:50:00 8.1 0.8 9.9 5.7 8 0.9 9.9 5.7 0.4 0 0.4 0.4 29 6 35 305 18 0 18 0 -10.3 0 -10 -10.4 03/23/2005 06:00:00 8.1 0.9 9.9 5.7 8 1 10.3 5.7 0.4 0 0.4 0.4 20 5 23 305 18 0 18 0 -10.3 0 -10 -10.4 03/23/2005 06:10:00 7.9 0.7 10.3 6.1 7.8 0.8 10.3 6.1 0.4 0 0.4 0.4 25 5 21 305 18 0 18 0 -10.3 0 -10 -10.7 03/23/2005 06:20:00 7.6 0.6 9.1 6.1 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 28 9 44 305 18 0 18 0 -10.4 0 -10.2 -10.7 03/23/2005 06:30:00 8.4 0.7 10.3 6.1 8.3 0.8 10.3 6.1 0.4 0 0.4 0.4 35 4 39 305 18 0 18 0 -10.3 0 -10.2 -10.4 03/23/2005 06:40:00 8 0.7 9.5 5.7 7.9 0.7 9.5 6.5 0.4 0 0.4 0.4 28 5 37 305 18 0 18 0 -10.4 0 -10.2 -10.7 03/23/2005 06:50:00 7.6 0.8 9.5 5.3 7.6 0.8 9.5 5.7 0.4 0 0.4 0.4 30 6 32 305 18 0 18 0 -10.4 0 -10.2 -10.7 03/23/2005 07:00:00 7.9 0.9 9.9 5.7 7.7 1 9.9 5.7 0.4 0 0.4 0.4 32 6 31 305 18 0 18 0 -10.4 0 -10.2 -10.4 03/23/2005 07:10:00 8.7 0.6 9.9 6.5 8.5 0.7 9.9 6.1 0.4 0 0.4 0.4 29 5 22 305 18 0 18 0 -10.4 0 -10.2 -10.7 03/23/2005 07:20:00 8.4 0.8 10.3 6.1 8.2 0.8 9.9 6.5 0.4 0 0.4 0.4 27 5 28 305 18 0 18 0 -10.4 0 -10.2 -10.7 03/23/2005 07:30:00 7.6 0.8 9.5 5.7 7.6 0.8 9.9 5.3 0.4 0 0.4 0.4 23 5 24 305 18 0 18 0 -10.4 0 -10.4 -10.7 03/23/2005 07:40:00 7.9 0.6 9.5 6.5 7.9 0.6 9.9 6.1 0.4 0 0.4 0.4 25 7 26 305 18 0 18 0 -10.5 0 -10.4 -10.9 03/23/2005 07:50:00 8.9 0.5 10.3 6.8 8.8 0.7 9.9 6.8 0.4 0 0.4 0.4 28 5 19 305 18 0 18 0 -10.7 0 -10.4 -10.9 03/23/2005 08:00:00 8.2 0.7 9.9 6.5 8.2 0.8 9.9 6.5 0.4 0 0.4 0.4 30 5 29 305 17 0 18 0 -10.7 0 -10.4 -10.9 03/23/2005 08:10:00 9.1 0.6 10.7 7.2 9 0.7 10.7 6.8 0.4 0 0.4 0.4 23 4 23 305 17 0 18 0 -10.6 0 -10.4 -10.9 03/23/2005 08:20:00 8.5 0.8 10.7 6.5 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 26 6 35 305 18 0 18 0 -10.5 0 -10.2 -10.7 03/23/2005 08:30:00 9 0.8 10.7 6.5 8.9 0.9 10.7 6.8 0.4 0 0.4 0.4 30 5 31 305 18 0 18 0 -10.5 0 -10.4 -10.7 03/23/2005 08:40:00 8.9 0.8 11.1 6.5 8.9 0.8 11.1 6.8 0.4 0 0.4 0.4 30 5 29 305 18 0 18 0 -10.4 0 -10.2 -10.7 03/23/2005 08:50:00 9.4 0.6 11.1 8 9.3 0.6 11.1 7.6 0.4 0 0.4 0.4 27 5 22 305 18 0 18 0 -10.5 0 -10.4 -10.7 03/23/2005 09:00:00 9.3 0.6 11.1 7.6 9.3 0.6 11.5 7.2 0.4 0 0.4 0.4 25 4 22 305 18 0 18 0 -10.6 0 -10.4 -10.9 03/23/2005 09:10:00 9.3 0.8 11.1 7.2 9.2 0.8 11.1 7.2 0.4 0 0.4 0.4 30 5 36 305 18 0 18 0 -10.6 0 -10.4 -10.9 03/23/2005 09:20:00 9.4 0.8 11.1 6.8 9.3 0.8 11.1 6.8 0.4 0 0.4 0.4 29 4 27 305 17 0 18 0 -10.7 0 -10.4 -10.9 03/23/2005 09:30:00 9 0.7 11.1 7.2 8.9 0.8 11.5 6.8 0.4 0 0.4 0.4 29 5 25 305 17 0 18 0 -10.6 0 -10.4 -10.9 03/23/2005 09:40:00 9.5 0.9 11.5 6.8 9.3 0.9 11.8 7.2 0.4 0 0.4 0.4 27 5 26 305 17 0 17 0 -10.7 0 -10.4 -10.9 03/23/2005 09:50:00 9.5 0.8 11.1 7.6 9.3 0.8 11.5 7.6 0.4 0 0.4 0.4 32 3 31 305 17 0 17 0 -10.6 0.1 -10.4 -10.9 03/23/2005 10:00:00 9.7 0.6 10.7 7.6 9.6 0.6 11.1 7.2 0.4 0 0.4 0.4 32 3 31 305 17 0 17 0 -10.7 0 -10.4 -10.9 03/23/2005 10:10:00 9.8 0.7 11.5 7.6 9.6 0.8 11.5 7.2 0.4 0 0.4 0.4 34 4 29 305 17 0 17 0 -10.5 0 -10.2 -10.9 03/23/2005 10:20:00 9.3 0.8 11.1 6.8 9.1 0.8 11.1 6.5 0.4 0 0.4 0.4 34 6 31 305 17 0 17 0 -10.4 0 -10.2 -10.7 03/23/2005 10:30:00 8.9 0.8 10.7 6.1 8.7 0.8 10.3 6.5 0.4 0 0.4 0.4 32 6 39 305 17 0 17 0 -10.4 0 -10.2 -10.4 03/23/2005 10:40:00 8.5 0.7 10.3 6.5 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 30 5 24 305 17 0 17 0 -10.3 0 -10 -10.4 03/23/2005 10:50:00 8.3 0.9 10.3 5.7 8.1 0.9 9.9 6.1 0.4 0 0.4 0.4 34 5 31 305 17 0 16 0 -10.4 0 -10 -10.4 03/23/2005 11:00:00 7.9 0.8 9.9 5.7 7.8 0.9 9.5 5.3 0.4 0 0.4 0.4 36 5 26 305 17 0 16 0 -10.2 0.1 -9.8 -10.4 03/23/2005 11:10:00 8.4 0.8 10.3 5.7 8.2 0.8 9.9 5.7 0.4 0 0.4 0.4 30 4 33 305 17 0 16 0 -10.1 0.1 -9.8 -10.4 03/23/2005 11:20:00 8.2 0.8 10.3 6.5 8 0.8 9.5 5.7 0.4 0 0.4 0.4 30 4 31 305 16 0 16 0 -10.1 0.1 -9.8 -10.4 03/23/2005 11:30:00 8 0.7 9.9 5.7 7.9 0.8 9.9 5.7 0.4 0 0.4 0.4 29 5 32 305 15 0 15 0 -10.1 0 -9.8 -10.4 03/23/2005 11:40:00 7.8 0.8 9.9 6.1 7.6 1 9.9 5.3 0.4 0 0.4 0.4 29 5 25 305 16 0 16 0 -9.8 0.1 -9.4 -10.2 03/23/2005 11:50:00 8.5 0.7 9.9 6.5 8.4 0.8 9.9 6.5 0.4 0 0.4 0.4 25 5 31 305 16 0 16 0 -9.7 0.1 -9.2 -10 03/23/2005 12:00:00 8.8 0.7 10.3 6.8 8.7 0.7 10.3 6.8 0.4 0 0.4 0.4 30 3 31 305 15 0 15 0 -9.7 0 -9.6 -10 03/23/2005 12:10:00 8.6 0.7 10.3 6.8 8.4 0.8 10.3 6.5 0.4 0 0.4 0.4 34 4 31 305 15 0 15 0 -9.7 0 -9.6 -9.8 03/23/2005 12:20:00 8.8 0.7 10.3 6.8 8.7 0.8 10.3 6.5 0.4 0 0.4 0.4 33 5 40 305 14 0 14 0 -9.5 0 -9.2 -9.8 03/23/2005 12:30:00 9.1 0.8 10.7 6.8 9 0.9 10.7 6.5 0.4 0 0.4 0.4 36 4 34 305 13 0 14 0 -9.5 0.1 -9.2 -9.6 03/23/2005 12:40:00 9.3 0.7 11.1 7.2 9.1 0.7 11.1 6.8 0.4 0 0.4 0.4 32 6 35 305 12 0 13 0 -9.5 0 -9.2 -9.8 03/23/2005 12:50:00 9 0.6 10.3 6.8 8.9 0.7 10.3 6.5 0.4 0 0.4 0.4 34 5 35 305 11 0 12 0 -9.5 0.1 -9.2 -9.8 03/23/2005 13:00:00 8.9 0.8 10.3 6.5 8.7 0.7 9.9 6.5 0.4 0 0.4 0.4 32 5 29 305 10 0 10 0 -9.6 0 -9.4 -9.8 03/23/2005 13:10:00 8.6 0.6 10.3 6.8 8.5 0.6 9.9 7.2 0.4 0 0.4 0.4 33 5 39 305 10 0 10 0 -9.4 0 -9.2 -9.6 03/23/2005 13:20:00 8.8 0.9 10.7 6.8 8.7 0.9 10.3 6.8 0.4 0 0.4 0.4 35 5 37 305 9 0 9 0 -9.3 0 -9.2 -9.4 03/23/2005 13:30:00 8.7 0.8 10.3 6.8 8.5 0.9 10.3 6.5 0.4 0 0.4 0.4 33 6 20 305 9 0 9 0 -9.2 0 -9 -9.4 03/23/2005 13:40:00 8.3 0.8 10.3 6.5 8.2 0.8 10.3 6.1 0.4 0 0.4 0.4 32 5 33 305 8 0 9 0 -9.2 0 -9 -9.2 03/23/2005 13:50:00 8.5 1 10.7 6.5 8.2 1 10.7 5.7 0.4 0 0.4 0.4 32 5 35 305 8 0 8 0 -9 0 -8.8 -9.2 03/23/2005 14:00:00 8.8 0.8 10.3 6.5 8.7 0.8 10.3 6.5 0.4 0 0.4 0.4 35 5 35 305 8 0 8 0 -8.8 0.2 -8.4 -9 03/23/2005 14:10:00 8.6 0.8 10.7 6.8 8.5 0.8 10.7 6.5 0.4 0 0.4 0.4 30 6 33 305 8 0 8 0 -8.7 0.1 -8.4 -9 03/23/2005 14:20:00 8.9 0.8 10.7 6.8 8.9 0.8 10.3 6.5 0.4 0 0.4 0.4 34 7 36 305 7 0 7 0 -8.6 0.1 -8.2 -8.8 03/23/2005 14:30:00 8.8 0.6 10.7 7.2 8.8 0.6 10.3 6.8 0.4 0 0.4 0.4 27 4 28 305 7 0 7 0 -8.6 0.1 -8.4 -8.8 03/23/2005 14:40:00 8.8 0.7 10.3 6.8 8.8 0.7 10.7 6.8 0.4 0 0.4 0.4 27 5 25 305 7 0 7 0 -8.6 0 -8.4 -8.8 03/23/2005 14:50:00 8.9 0.9 11.1 6.8 8.9 0.9 11.1 6.5 0.4 0 0.4 0.4 28 6 22 305 7 0 7 0 -8.5 0.1 -8.2 -8.6 03/23/2005 15:00:00 8.7 0.6 10.3 6.8 8.6 0.7 10.3 6.5 0.4 0 0.4 0.4 29 6 29 305 6 0 6 0 -8.4 0 -8.2 -8.6 03/23/2005 15:10:00 8 0.8 9.9 6.1 8 0.8 9.9 6.5 0.4 0 0.4 0.4 29 6 23 305 6 0 6 0 -8.4 0 -8.2 -8.6 03/23/2005 15:20:00 8.8 0.7 10.7 6.8 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 32 5 27 305 6 0 6 0 -8.5 0.1 -8.2 -8.8 03/23/2005 15:30:00 8.4 0.6 9.9 6.8 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 30 5 29 305 5 0 6 0 -8.6 0.1 -8.4 -8.8 03/23/2005 15:40:00 8.7 0.6 9.9 6.8 8.6 0.7 9.9 6.8 0.4 0 0.4 0.4 30 5 33 305 5 0 5 0 -8.7 0 -8.4 -8.8 03/23/2005 15:50:00 8.5 0.8 10.3 6.8 8.4 0.8 10.3 6.5 0.4 0 0.4 0.4 29 7 24 305 5 0 5 0 -8.7 0 -8.4 -9.2 03/23/2005 16:00:00 8.5 0.8 10.7 6.1 8.3 0.9 10.7 6.1 0.4 0 0.4 0.4 28 6 37 305 5 0 5 0 -8.8 0 -8.6 -9 03/23/2005 16:10:00 8.7 0.8 10.7 6.8 8.6 0.8 10.7 6.5 0.4 0 0.4 0.4 29 7 37 305 5 0 5 0 -8.9 0 -8.8 -9 03/23/2005 16:20:00 9 0.6 10.7 6.8 8.9 0.7 10.3 6.8 0.4 0 0.4 0.4 27 4 29 305 5 0 5 0 -9 0 -8.8 -9.2 03/23/2005 16:30:00 9 0.7 10.7 7.2 8.9 0.7 10.7 6.8 0.4 0 0.4 0.4 28 8 18 305 5 0 5 0 -9 0 -8.8 -9.2 03/23/2005 16:40:00 9.1 0.7 10.7 6.8 9 0.8 11.1 6.8 0.4 0 0.4 0.4 26 4 27 305 5 0 5 0 -8.9 0 -8.6 -9.2 03/23/2005 16:50:00 8.5 0.8 10.3 6.5 8.4 0.8 10.7 6.1 0.4 0 0.4 0.4 28 7 19 305 5 0 5 0 -8.8 0 -8.6 -9 03/23/2005 17:00:00 8.5 0.8 10.3 6.1 8.3 0.8 9.9 5.7 0.4 0 0.4 0.4 32 6 23 305 5 0 5 0 -8.8 0 -8.6 -9 03/23/2005 17:10:00 8.7 0.7 11.1 6.5 8.5 0.8 9.9 6.1 0.4 0 0.4 0.4 24 5 20 305 5 0 5 0 -9 0 -8.8 -9.2 03/23/2005 17:20:00 8.4 0.7 9.9 6.5 8.4 0.8 9.9 6.1 0.4 0 0.4 0.4 30 5 27 305 5 0 5 0 -9.1 0 -8.8 -9.2 03/23/2005 17:30:00 8.4 0.6 9.9 6.8 8.3 0.7 9.5 6.5 0.4 0 0.4 0.4 28 6 25 305 5 0 5 0 -9 0 -8.8 -9.2 03/23/2005 17:40:00 8.6 0.8 10.7 6.8 8.4 0.8 11.1 6.8 0.4 0 0.4 0.4 24 5 22 305 5 0 5 0 -9 0 -8.8 -9.2 03/23/2005 17:50:00 8.5 0.7 10.3 6.8 8.4 0.7 10.3 6.5 0.4 0 0.4 0.4 29 7 37 305 5 0 5 0 -9.1 0 -8.8 -9.2 03/23/2005 18:00:00 8.8 0.9 10.7 6.1 8.7 0.9 10.7 6.1 0.4 0 0.4 0.4 27 5 31 305 5 0 5 0 -9.2 0 -9 -9.2 03/23/2005 18:10:00 8.2 0.9 10.7 6.5 8 0.9 10.3 6.1 0.4 0 0.4 0.4 33 6 39 305 5 0 5 0 -9.1 0.1 -8.8 -9.2 03/23/2005 18:20:00 8.2 0.8 10.3 6.5 8.1 0.7 9.5 6.5 0.4 0 0.4 0.4 26 5 32 305 5 0 5 0 -9.3 0 -9 -9.6 03/23/2005 18:30:00 8.3 0.8 9.9 6.5 8.2 0.8 9.9 6.1 0.4 0 0.4 0.4 27 4 20 305 5 0 5 0 -9.3 0 -9 -9.4 03/23/2005 18:40:00 8 0.7 9.9 5.3 8 0.7 9.9 6.1 0.4 0 0.4 0.4 28 5 36 305 5 0 5 0 -9.1 0.1 -8.8 -9.2 03/23/2005 18:50:00 8.7 1 10.7 6.1 8.6 1.1 10.7 5.7 0.4 0 0.4 0.4 27 6 21 305 5 0 5 0 -9.2 0 -8.8 -9.4 03/23/2005 19:00:00 9.3 0.5 10.3 7.6 9.1 0.6 10.7 7.6 0.4 0 0.4 0.4 29 4 26 305 5 0 5 0 -9.5 0 -9.2 -9.6 03/23/2005 19:10:00 9 0.7 10.3 7.2 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 28 5 33 305 5 0 5 0 -9.5 0 -9.2 -9.6 03/23/2005 19:20:00 8.3 0.8 10.3 6.1 8.3 0.8 10.3 5.7 0.4 0 0.4 0.4 27 5 23 305 5 0 5 0 -9.7 0.1 -9.4 -9.8 03/23/2005 19:30:00 8 0.8 9.9 6.1 7.8 0.8 9.9 5.7 0.4 0 0.4 0.4 28 6 22 305 5 0 5 0 -9.7 0 -9.4 -9.8 03/23/2005 19:40:00 8.9 0.8 10.7 6.5 8.7 0.8 10.7 6.5 0.4 0 0.4 0.4 29 6 32 305 5 0 5 0 -9.7 0.1 -9.4 -10 03/23/2005 19:50:00 9.1 0.7 11.1 6.5 8.9 0.8 10.7 6.5 0.4 0 0.4 0.4 26 5 22 305 5 0 5 0 -9.8 0 -9.6 -10 03/23/2005 20:00:00 9.2 0.8 11.5 7.6 9 0.8 11.1 7.2 0.4 0 0.4 0.4 28 5 25 305 5 0 6 0 -9.9 0 -9.8 -10 03/23/2005 20:10:00 9.7 0.7 11.5 8.4 9.5 0.8 11.8 7.2 0.4 0 0.4 0.4 30 4 27 305 6 0 6 0 -9.9 0 -9.8 -10 03/23/2005 20:20:00 10.2 1 12.2 7.6 9.9 1 12.2 6.8 0.4 0 0.4 0.4 32 4 32 305 6 0 6 0 -9.9 0 -9.6 -10 03/23/2005 20:30:00 10.4 0.9 12.2 7.2 10.2 1 11.8 6.8 0.4 0 0.4 0.4 33 4 33 305 6 0 6 0 -10 0 -9.8 -10.2 03/23/2005 20:40:00 9.5 0.8 11.1 7.2 9.3 0.8 10.7 7.6 0.4 0 0.4 0.4 40 5 40 305 7 0 6 0 -10 0 -9.8 -10 03/23/2005 20:50:00 9.7 0.8 11.1 7.6 9.4 0.7 11.1 7.6 0.4 0 0.4 0.4 38 4 26 305 7 0 7 0 -10.1 0 -10 -10.2 03/23/2005 21:00:00 9.5 1 11.8 7.2 9.2 1 12.2 6.8 0.4 0 0.4 0.4 39 5 40 305 7 0 7 0 -10.2 0 -10 -10.4 03/23/2005 21:10:00 9.9 0.7 11.8 7.6 9.7 0.8 11.5 7.6 0.4 0 0.4 0.4 40 6 46 305 7 0 7 0 -10.3 0 -10 -10.4 03/23/2005 21:20:00 9.9 0.8 11.8 8 9.7 0.9 11.5 7.6 0.4 0 0.4 0.4 39 5 32 305 7 0 7 0 -10.3 0 -10 -10.4 03/23/2005 21:30:00 10.4 0.8 13 8.4 10.2 0.9 12.6 8 0.4 0 0.4 0.4 41 5 37 305 8 0 7 0 -10.3 0 -10.2 -10.4 03/23/2005 21:40:00 10.5 0.6 12.6 8.4 10.3 0.7 12.2 8.4 0.4 0 0.4 0.4 36 5 29 305 8 0 8 0 -10.3 0 -10 -10.4 03/23/2005 21:50:00 10.6 1.1 13 8 10.4 1.1 13 8 0.4 0 0.4 0.4 40 4 41 305 8 0 8 0 -10.3 0 -10 -10.4 03/23/2005 22:00:00 10.7 1 12.6 8.4 10.5 1.1 13 8 0.4 0 0.4 0.4 34 5 37 305 8 0 8 0 -10.2 0 -10 -10.4 03/23/2005 22:10:00 10.9 1 12.6 8 10.5 1.1 12.6 8 0.4 0 0.4 0.4 33 5 37 305 8 0 8 0 -10.3 0 -10.2 -10.4 03/23/2005 22:20:00 11.3 0.8 13 8 11 1 12.6 8 0.4 0 0.4 0.4 35 5 35 305 8 0 8 0 -10.3 0 -10.2 -10.4 03/23/2005 22:30:00 10.8 0.9 13 8.4 10.5 0.9 12.6 8.4 0.4 0 0.4 0.4 30 5 22 305 8 0 8 0 -10.3 0 -10.2 -10.4 03/23/2005 22:40:00 10.7 0.9 13 8.4 10.4 0.9 12.6 8 0.4 0 0.4 0.4 31 5 32 305 8 0 8 0 -10.4 0 -10.2 -10.4 03/23/2005 22:50:00 10.3 0.8 12.2 8.4 10.1 1 12.2 7.2 0.4 0 0.4 0.4 27 5 27 305 8 0 8 0 -10.4 0 -10.2 -10.4 03/23/2005 23:00:00 10.4 1.1 12.6 7.2 10.2 1.1 13 7.2 0.4 0 0.4 0.4 28 5 24 305 8 0 8 0 -10.4 0 -10.2 -10.4 03/23/2005 23:10:00 9.7 1.3 12.6 6.8 9.6 1.3 12.2 6.8 0.4 0 0.4 0.4 29 7 22 305 8 0 8 0 -10.4 0 -10.4 -10.7 03/23/2005 23:20:00 10.4 1.2 13.3 8 10.2 1.2 13.3 8 0.4 0 0.4 0.4 33 5 32 305 8 0 8 0 -10.4 0 -10.2 -10.7 03/23/2005 23:30:00 11.8 1 13.7 9.1 11.6 1.1 13.7 8.8 0.4 0 0.4 0.4 31 3 30 305 8 0 8 0 -10.4 0 -10.4 -10.7 03/23/2005 23:40:00 10.3 1.1 13 6.5 10 1.2 12.6 6.5 0.4 0 0.4 0.4 28 6 27 305 8 0 8 0 -10.5 0 -10.4 -10.9 03/23/2005 23:50:00 10.4 1 12.6 7.6 10.2 1 12.6 7.6 0.4 0 0.4 0.4 28 5 31 305 8 0 8 0 -10.5 0 -10.4 -10.9 03/24/2005 00:00:00 10.1 1.1 12.2 7.2 9.9 1.2 12.2 7.2 0.4 0 0.4 0.4 31 4 34 305 8 0 8 0 -10.5 0 -10.2 -10.9 03/24/2005 00:10:00 10.2 0.7 11.8 8 9.9 0.8 11.8 7.6 0.4 0 0.4 0.4 32 5 38 305 8 0 8 0 -10.6 0 -10.4 -10.9 03/24/2005 00:20:00 9.5 0.8 11.5 7.6 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 36 6 31 305 8 0 8 0 -10.7 0.1 -10.4 -10.9 03/24/2005 00:30:00 9.5 0.8 11.5 7.2 9.4 0.9 11.1 6.8 0.4 0 0.4 0.4 34 4 33 305 8 0 8 0 -10.7 0 -10.4 -10.9 03/24/2005 00:40:00 9 0.7 10.3 6.8 8.7 0.7 10.3 6.5 0.4 0 0.4 0.4 38 5 29 305 8 0 8 0 -10.7 0 -10.4 -10.9 03/24/2005 00:50:00 8.6 0.7 9.5 6.8 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 35 5 43 305 8 0 8 0 -10.6 0 -10.4 -10.9 03/24/2005 01:00:00 8.8 0.6 10.3 6.5 8.8 0.7 10.3 6.5 0.4 0 0.4 0.4 27 4 30 305 8 0 8 0 -10.5 0 -10.4 -10.7 03/24/2005 01:10:00 8.1 0.8 9.5 6.1 8 0.7 9.9 5.7 0.4 0 0.4 0.4 27 5 29 305 8 0 8 0 -10.5 0 -10.4 -10.9 03/24/2005 01:20:00 8 0.7 9.5 5.7 8 0.8 9.9 6.1 0.4 0 0.4 0.4 26 6 27 305 8 0 8 0 -10.5 0 -10.4 -10.7 03/24/2005 01:30:00 8.6 0.9 10.3 6.1 8.5 1 10.7 5.7 0.4 0 0.4 0.4 26 5 29 305 8 0 8 0 -10.6 0 -10.4 -10.9 03/24/2005 01:40:00 8.3 0.8 9.9 6.5 8.3 0.8 9.9 6.1 0.4 0 0.4 0.4 22 6 23 305 8 0 8 0 -10.7 0 -10.4 -10.9 03/24/2005 01:50:00 8.4 0.7 9.9 6.1 8.4 0.7 9.9 5.7 0.4 0 0.4 0.4 24 5 27 305 8 0 8 0 -10.9 0 -10.7 -11.1 03/24/2005 02:00:00 8.3 0.7 10.3 6.8 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 28 5 24 305 8 0 8 0 -10.9 0 -10.9 -11.1 03/24/2005 02:10:00 8.4 0.6 9.9 6.5 8.4 0.7 9.9 6.5 0.4 0 0.4 0.4 25 6 23 305 8 0 8 0 -11 0 -10.9 -11.3 03/24/2005 02:20:00 8 1 10.7 5.3 8 1 10.3 5.7 0.4 0 0.4 0.4 25 7 26 305 8 0 8 0 -11 0 -10.9 -11.3 03/24/2005 02:30:00 8.3 1 10.3 6.1 8.2 1 10.7 5.3 0.4 0 0.4 0.4 25 5 28 305 8 0 8 0 -11 0 -10.9 -11.1 03/24/2005 02:40:00 8.9 0.8 10.7 6.8 8.8 0.8 10.7 6.8 0.4 0 0.4 0.4 29 5 28 305 8 0 8 0 -11 0 -10.9 -11.3 03/24/2005 02:50:00 8.9 0.9 10.7 6.1 8.7 0.8 10.3 6.1 0.4 0 0.4 0.4 28 5 30 305 8 0 8 0 -11 0 -10.9 -11.3 03/24/2005 03:00:00 9.3 0.7 10.7 6.5 9.1 0.7 10.7 6.8 0.4 0 0.4 0.4 26 3 23 305 8 0 8 0 -11.1 0 -10.9 -11.3 03/24/2005 03:10:00 8.7 0.6 9.9 6.5 8.7 0.7 10.3 6.8 0.4 0 0.4 0.4 23 4 25 305 8 0 8 0 -11.1 0 -10.9 -11.3 03/24/2005 03:20:00 8.2 0.7 9.5 6.1 8.1 0.7 9.5 6.1 0.4 0 0.4 0.4 21 4 20 305 9 0 9 0 -11.1 0 -10.9 -11.3 03/24/2005 03:30:00 7.8 0.5 9.1 6.1 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 23 4 22 305 9 0 9 0 -11.1 0 -10.9 -11.3 03/24/2005 03:40:00 7.9 0.6 9.1 6.1 7.8 0.8 9.5 5.3 0.4 0 0.4 0.4 20 7 26 305 9 0 9 0 -11.1 0 -10.9 -11.3 03/24/2005 03:50:00 7.2 0.6 8.4 5.3 7.1 0.7 8.4 5.3 0.4 0 0.4 0.4 16 4 13 305 9 0 9 0 -11.1 0 -10.9 -11.3 03/24/2005 04:00:00 7.2 0.6 8.4 5.3 7.1 0.7 8.4 5.3 0.4 0 0.4 0.4 26 6 29 305 9 0 9 0 -11.1 0 -10.9 -11.3 03/24/2005 04:10:00 7.1 0.5 8.4 5.3 6.9 0.6 8.4 4.9 0.4 0 0.4 0.4 30 3 30 305 9 0 9 0 -11.2 0 -10.9 -11.3 03/24/2005 04:20:00 6.3 0.6 7.6 4.6 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 25 6 32 305 9 0 9 0 -11.1 0 -10.9 -11.3 03/24/2005 04:30:00 6.5 0.6 7.6 4.6 6.5 0.6 7.6 4.9 0.4 0 0.4 0.4 25 5 30 305 9 0 9 0 -11.2 0 -10.9 -11.3 03/24/2005 04:40:00 6.4 0.6 8 4.6 6.5 0.6 8 4.6 0.4 0 0.4 0.4 23 4 27 305 9 0 9 0 -11.2 0 -10.9 -11.3 03/24/2005 04:50:00 6.5 0.5 7.6 4.9 6.6 0.5 7.6 4.9 0.4 0 0.4 0.4 21 4 14 305 9 0 9 0 -11.3 0.1 -11.1 -11.5 03/24/2005 05:00:00 6.5 0.6 8 4.9 6.6 0.6 8 5.3 0.4 0 0.4 0.4 22 5 26 305 9 0 9 0 -11.4 0 -11.1 -11.5 03/24/2005 05:10:00 6.5 0.5 8 5.3 6.6 0.5 8 5.3 0.4 0 0.4 0.4 24 5 22 305 9 0 9 0 -11.4 0 -11.3 -11.5 03/24/2005 05:20:00 5.9 0.5 6.8 4.6 6 0.5 7.2 4.6 0.4 0 0.4 0.4 16 6 25 305 9 0 9 0 -11.4 0 -11.3 -11.5 03/24/2005 05:30:00 5.9 0.5 7.6 4.2 6 0.5 7.2 4.2 0.4 0 0.4 0.4 19 6 12 305 9 0 9 0 -11.5 0 -11.3 -11.7 03/24/2005 05:40:00 6.1 0.5 6.8 4.2 6.2 0.5 7.2 4.6 0.4 0 0.4 0.4 20 5 22 305 9 0 9 0 -11.5 0 -11.3 -11.7 03/24/2005 05:50:00 5.8 0.5 6.8 4.6 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 18 5 15 305 9 0 9 0 -11.5 0 -11.3 -11.7 03/24/2005 06:00:00 5.7 0.5 6.8 4.6 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 15 7 20 305 9 0 9 0 -11.5 0 -11.3 -11.7 03/24/2005 06:10:00 5.3 0.4 6.5 4.2 5.4 0.4 6.5 4.6 0.4 0 0.4 0.4 13 5 7 305 9 0 9 0 -11.5 0 -11.3 -11.7 03/24/2005 06:20:00 5.6 0.5 6.8 4.2 5.7 0.6 6.8 4.2 0.4 0 0.4 0.4 17 5 22 305 8 0 9 0 -11.5 0 -11.3 -11.7 03/24/2005 06:30:00 6.2 0.4 6.8 4.9 6.3 0.4 7.2 4.9 0.4 0 0.4 0.4 19 3 21 305 8 0 8 0 -11.5 0 -11.5 -11.7 03/24/2005 06:40:00 5.6 0.5 6.8 4.2 5.7 0.5 7.2 3.8 0.4 0 0.4 0.4 18 5 12 305 8 0 8 0 -11.5 0 -11.3 -11.7 03/24/2005 06:50:00 5.5 0.5 6.5 3.8 5.6 0.6 6.8 3.8 0.4 0 0.4 0.4 20 5 27 305 8 0 8 0 -11.5 0 -11.3 -11.7 03/24/2005 07:00:00 5.2 0.5 6.1 4.2 5.3 0.5 6.5 4.2 0.4 0 0.4 0.4 21 5 17 305 9 0 9 0 -11.5 0 -11.3 -11.7 03/24/2005 07:10:00 5.4 0.5 6.5 3.8 5.5 0.5 6.5 4.2 0.4 0 0.4 0.4 25 4 31 305 8 0 8 0 -11.5 0 -11.3 -11.7 03/24/2005 07:20:00 5.2 0.4 6.1 3.8 5.3 0.4 6.1 3.8 0.4 0 0.4 0.4 17 5 12 305 8 0 8 0 -11.5 0 -11.3 -11.7 03/24/2005 07:30:00 4.9 0.6 6.5 3.8 5 0.6 6.5 3.8 0.4 0 0.4 0.4 18 4 20 305 9 0 9 0 -11.5 0 -11.3 -11.7 03/24/2005 07:40:00 5.4 0.5 6.5 3.8 5.4 0.5 6.8 3.8 0.4 0 0.4 0.4 16 4 15 305 9 0 9 0 -11.3 0 -11.1 -11.5 03/24/2005 07:50:00 5.4 0.4 6.5 4.6 5.6 0.4 6.5 4.6 0.4 0 0.4 0.4 20 3 24 305 9 0 9 0 -11.3 0 -11.1 -11.5 03/24/2005 08:00:00 5.3 0.4 6.1 3.8 5.4 0.5 6.5 4.2 0.4 0 0.4 0.4 21 5 16 305 9 0 9 0 -11.3 0 -11.1 -11.3 03/24/2005 08:10:00 5.1 0.4 6.1 3.8 5.2 0.5 6.1 3.8 0.4 0 0.4 0.4 19 4 17 305 9 0 9 0 -11.3 0 -11.3 -11.5 03/24/2005 08:20:00 4.5 0.4 5.3 3.4 4.7 0.4 5.7 3.4 0.4 0 0.4 0.4 21 3 18 305 9 0 9 0 -11.4 0 -11.3 -11.5 03/24/2005 08:30:00 4.9 0.4 5.7 3.8 5 0.5 6.1 3.8 0.4 0 0.4 0.4 17 5 11 305 9 0 9 0 -11.4 0 -11.1 -11.5 03/24/2005 08:40:00 5.3 0.3 6.1 4.2 5.4 0.4 6.1 4.2 0.4 0 0.4 0.4 13 4 8 305 9 0 9 0 -11.4 0 -11.3 -11.5 03/24/2005 08:50:00 5 0.4 5.7 3.8 5.2 0.4 6.1 4.2 0.4 0 0.4 0.4 12 4 12 305 9 0 9 0 -11.4 0 -11.1 -11.5 03/24/2005 09:00:00 4.7 0.4 5.7 3.8 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 14 4 20 305 9 0 9 0 -11.3 0 -11.1 -11.5 03/24/2005 09:10:00 5 0.4 6.1 3.8 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 6 5 6 305 9 0 9 0 -11.2 0 -10.9 -11.5 03/24/2005 09:20:00 4.3 0.5 5.7 3.4 4.4 0.5 5.7 3.4 0.4 0 0.4 0.4 9 5 359 305 9 0 9 0 -11.2 0 -10.9 -11.3 03/24/2005 09:30:00 5 0.4 6.1 3.8 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 14 3 13 305 9 0 9 0 -11.2 0 -10.9 -11.3 03/24/2005 09:40:00 5 0.5 5.7 3.8 5 0.5 6.1 3.4 0.4 0 0.4 0.4 15 5 14 305 9 0 9 0 -10.9 0.1 -10.4 -11.3 03/24/2005 09:50:00 5.2 0.4 6.1 4.2 5.3 0.4 6.1 4.2 0.4 0 0.4 0.4 12 3 12 305 10 0 9 0 -10.6 0 -10.4 -10.9 03/24/2005 10:00:00 5.1 0.6 6.5 3.8 5.2 0.5 6.5 3.8 0.4 0 0.4 0.4 13 4 10 305 9 0 10 0 -10.5 0 -10.2 -10.9 03/24/2005 10:10:00 5.2 0.6 6.8 3.8 5.2 0.6 6.8 3.8 0.4 0 0.4 0.4 13 4 14 305 9 0 8 0 -10.5 0 -10.2 -10.9 03/24/2005 10:20:00 5.1 0.5 6.1 3.4 5.2 0.6 6.5 3.8 0.4 0 0.4 0.4 13 5 8 305 8 0 8 0 -10.5 0 -10.2 -10.7 03/24/2005 10:30:00 5.1 0.5 6.5 3.8 5.1 0.5 6.8 4.2 0.4 0 0.4 0.4 7 5 7 305 7 0 8 0 -10.5 0 -10.2 -10.9 03/24/2005 10:40:00 5.1 0.6 6.5 3.8 5.3 0.6 6.5 3.4 0.4 0 0.4 0.4 3 5 358 305 7 0 7 0 -10.5 0 -10.2 -10.9 03/24/2005 10:50:00 5 0.4 5.7 4.2 5.1 0.4 6.1 4.2 0.4 0 0.4 0.4 9 3 8 305 7 0 7 0 -10.5 0 -10.2 -10.9 03/24/2005 11:00:00 5.1 0.3 6.1 3.8 5.2 0.4 6.1 3.8 0.4 0 0.4 0.4 7 3 3 305 6 0 6 0 -10.4 0 -10 -10.7 03/24/2005 11:10:00 5 0.5 6.5 3.8 5.1 0.5 6.5 3.4 0.4 0 0.4 0.4 13 4 14 305 6 0 6 0 -10.4 0 -10 -10.4 03/24/2005 11:20:00 4.6 0.5 5.7 3.4 4.6 0.4 5.7 3.4 0.4 0 0.4 0.4 8 5 10 305 6 0 6 0 -10.4 0 -10 -10.7 03/24/2005 11:30:00 4.8 0.4 5.7 3.8 4.9 0.4 6.1 3.4 0.4 0 0.4 0.4 1 5 1 305 5 0 5 0 -10.4 0 -10 -10.7 03/24/2005 11:40:00 4.7 0.6 6.1 3.4 4.8 0.5 6.1 3 0.4 0 0.4 0.4 7 6 10 305 5 0 5 0 -10.2 0.1 -9.8 -10.4 03/24/2005 11:50:00 5.2 0.4 6.1 3.8 5.3 0.4 6.1 4.2 0.4 0 0.4 0.4 9 3 9 305 5 0 5 0 -10.1 0 -9.8 -10.4 03/24/2005 12:00:00 4.7 0.4 5.7 3.4 4.8 0.4 6.1 3.8 0.4 0 0.4 0.4 7 6 9 305 5 0 5 0 -10 0 -9.6 -10 03/24/2005 12:10:00 4.4 0.4 5.3 3 4.5 0.5 5.3 3.4 0.4 0 0.4 0.4 11 4 10 305 5 0 5 0 -9.9 0.1 -9.6 -10.2 03/24/2005 12:20:00 4 0.5 5.3 3 4.1 0.5 5.3 3 0.4 0 0.4 0.4 6 7 16 305 5 0 5 0 -9.8 0 -9.4 -10 03/24/2005 12:30:00 3.8 0.4 5.3 2.6 3.9 0.4 5.3 3 0.4 0 0.4 0.4 11 8 8 305 4 0 4 0 -9.8 0 -9.4 -10 03/24/2005 12:40:00 4.1 0.5 4.9 2.6 4.2 0.5 5.3 3 0.4 0 0.4 0.4 7 6 2 305 4 0 4 0 -9.7 0.1 -9.2 -9.8 03/24/2005 12:50:00 3.8 0.5 4.9 2.6 3.9 0.5 5.3 2.6 0.4 0 0.4 0.4 8 5 3 305 4 0 4 0 -9.6 0.1 -9.2 -9.8 03/24/2005 13:00:00 3.7 0.4 4.6 2.6 3.7 0.5 4.6 2.3 0.4 0 0.4 0.4 11 5 11 305 4 0 4 0 -9.4 0.1 -9 -9.6 03/24/2005 13:10:00 3.4 0.4 4.2 2.3 3.4 0.4 4.2 2.6 0.4 0 0.4 0.4 7 6 0 305 4 0 4 0 -9.1 0 -8.8 -9.2 03/24/2005 13:20:00 3 0.4 3.8 1.9 3.1 0.4 4.2 1.9 0.4 0 0.4 0.4 4 7 357 305 4 0 4 0 -8.8 0.1 -8.4 -9.2 03/24/2005 13:30:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 0.4 0 0.4 0.4 356 6 348 305 3 0 3 0 -8.8 0 -8.4 -9 03/24/2005 13:40:00 3.3 0.4 4.2 2.3 3.5 0.4 4.6 2.6 0.4 0 0.4 0.4 352 8 357 305 3 0 3 0 -8.6 0.2 -8.2 -9 03/24/2005 13:50:00 3.9 0.4 5.3 3 4 0.5 4.9 2.6 0.4 0 0.4 0.4 344 7 354 305 2 0 2 0 -8.8 0.1 -8.6 -9.2 03/24/2005 14:00:00 4.3 0.4 5.3 2.6 4.5 0.4 5.3 3.4 0.4 0 0.4 0.4 348 6 341 305 2 0 2 0 -9.1 0 -9 -9.2 03/24/2005 14:10:00 3.9 0.5 4.9 2.3 4.1 0.5 5.3 2.6 0.4 0 0.4 0.4 350 6 347 305 2 0 2 0 -9 0 -8.8 -9.2 03/24/2005 14:20:00 4.6 0.5 5.7 3.4 4.7 0.5 6.1 3.4 0.4 0 0.4 0.4 354 5 355 305 2 0 2 0 -9 0 -8.8 -9.2 03/24/2005 14:30:00 3.9 0.6 5.3 2.6 4 0.6 5.7 3 0.4 0 0.4 0.4 344 7 347 305 3 0 2 0 -8.7 0 -8.4 -9 03/24/2005 14:40:00 4.3 0.4 5.3 3 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 348 5 344 305 3 0 2 0 -8.6 0.1 -8.4 -8.8 03/24/2005 14:50:00 4.3 0.6 5.7 3 4.4 0.6 6.1 3 0.4 0 0.4 0.4 350 7 3 305 2 0 2 0 -8.7 0 -8.4 -8.8 03/24/2005 15:00:00 4.5 0.5 5.7 3.4 4.7 0.5 5.7 3.4 0.4 0 0.4 0.4 354 6 8 305 2 0 2 0 -8.6 0 -8.4 -8.8 03/24/2005 15:10:00 4.6 0.6 5.7 3 4.8 0.6 6.1 3.4 0.4 0 0.4 0.4 353 6 353 305 3 0 2 0 -8.5 0 -8.4 -8.8 03/24/2005 15:20:00 4.5 0.4 5.3 3.4 4.6 0.4 6.1 3.8 0.4 0 0.4 0.4 353 5 354 305 3 0 2 0 -8.5 0 -8.2 -8.6 03/24/2005 15:30:00 4.3 0.6 6.1 3 4.5 0.7 6.1 3 0.4 0 0.4 0.4 355 6 353 305 3 0 3 0 -8.2 0 -7.9 -8.4 03/24/2005 15:40:00 5 0.6 6.5 3 5.1 0.7 6.5 3.4 0.4 0 0.4 0.4 352 5 352 305 3 0 3 0 -8.2 0 -7.9 -8.4 03/24/2005 15:50:00 4.7 0.5 5.7 3.8 4.9 0.5 6.1 3.8 0.4 0 0.4 0.4 352 6 352 305 3 0 3 0 -7.9 0.1 -7.7 -8.2 03/24/2005 16:00:00 4.2 0.5 5.3 3 4.4 0.5 5.3 3 0.4 0 0.4 0.4 355 6 355 305 3 0 3 0 -7.9 0.2 -7.3 -8.2 03/24/2005 16:10:00 4.3 0.4 5.3 3 4.5 0.4 5.7 3.4 0.4 0 0.4 0.4 355 6 353 305 3 0 3 0 -8 0.2 -7.3 -8.4 03/24/2005 16:20:00 3.9 0.7 7.6 2.6 4.1 0.6 8 3 0.4 0 0.4 0.4 349 9 318 305 3 0 3 0 -8.3 0 -8.2 -8.4 03/24/2005 16:30:00 6.2 0.5 7.2 4.9 6 0.5 8.4 4.6 0.4 0 0.4 0.4 306 15 324 305 3 1 3 0 -8.3 0 -8.2 -8.4 03/24/2005 16:40:00 6.1 0.5 7.6 4.6 5.8 0.5 7.2 4.2 0.4 0 0.4 0.4 306 11 303 305 3 1 4 0 -8.1 0.1 -7.7 -8.4 03/24/2005 16:50:00 6 0.4 7.2 4.9 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 306 10 303 305 3 1 2 0 -8.1 0 -7.7 -8.2 03/24/2005 17:00:00 5.9 0.5 7.2 4.6 5.6 0.4 6.8 4.2 0.4 0 0.4 0.4 304 12 292 305 3 1 2 0 -8.2 0 -7.7 -8.4 03/24/2005 17:10:00 6.6 0.6 8 5.3 6.2 0.5 7.6 4.9 0.4 0 0.4 0.4 305 11 305 305 2 1 4 0 -8.3 0 -7.9 -8.4 03/24/2005 17:20:00 6.7 0.5 8 5.3 6.2 0.5 7.6 4.9 0.4 0 0.4 0.4 304 7 305 305 2 1 4 0 -8.2 0 -7.9 -8.4 03/24/2005 17:30:00 6.1 0.6 7.2 4.2 5.6 0.6 6.8 4.2 0.4 0 0.4 0.4 303 9 302 305 2 1 1 0 -8.4 0 -8.2 -8.6 03/24/2005 17:40:00 6.2 0.5 7.6 4.9 5.8 0.6 7.2 4.2 0.4 0 0.4 0.4 302 7 303 305 2 1 3 0 -8.4 0 -8.2 -8.6 03/24/2005 17:50:00 5.9 0.9 7.6 3.4 5.6 0.9 7.2 3 0.4 0 0.4 0.4 297 8 305 305 2 1 3 0 -8.3 0 -8.2 -8.4 03/24/2005 18:00:00 5.3 0.6 6.8 3.8 4.6 0.6 5.7 2.6 0.4 0 0.4 0.4 287 10 275 305 2 0 2 0 -8.3 0 -8.2 -8.6 03/24/2005 18:10:00 6.4 0.6 7.6 4.2 5.8 0.7 7.2 3.8 0.4 0 0.4 0.4 289 7 293 305 2 0 2 0 -8.7 0 -8.4 -8.8 03/24/2005 18:20:00 6.2 0.6 8 4.6 5.7 0.6 6.8 4.2 0.4 0 0.4 0.4 291 6 291 305 2 0 2 0 -8.6 0 -8.4 -8.8 03/24/2005 18:30:00 6.1 0.6 7.6 4.6 5.4 0.6 6.8 3.8 0.4 0 0.4 0.4 291 6 298 305 3 0 5 0 -8.6 0 -8.4 -8.8 03/24/2005 18:40:00 6.3 0.7 7.6 4.6 5.8 0.7 7.6 4.2 0.4 0 0.4 0.4 301 8 305 305 4 1 3 0 -8.6 0 -8.4 -8.8 03/24/2005 18:50:00 5.9 0.7 7.6 4.2 5.9 0.7 7.6 3.8 0.4 0 0.4 0.4 329 9 333 305 5 0 5 0 -8.7 0 -8.4 -9 03/24/2005 19:00:00 5 0.8 6.8 3 4.9 0.8 6.8 3.4 0.4 0 0.4 0.4 329 5 327 305 5 0 5 0 -8.9 0 -8.8 -9 03/24/2005 19:10:00 4.2 0.6 6.1 2.6 4.3 0.6 6.1 3 0.4 0 0.4 0.4 334 6 330 305 5 0 5 0 -8.9 0 -8.8 -9.2 03/24/2005 19:20:00 4.4 0.5 5.7 3 4.2 0.5 5.3 3 0.4 0 0.4 0.4 330 4 331 305 5 0 5 0 -9.2 0 -9 -9.4 03/24/2005 19:30:00 4.6 0.5 5.7 3.4 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 331 3 331 305 5 0 6 0 -9.4 0 -9.2 -9.6 03/24/2005 19:40:00 3.8 0.4 4.9 2.6 3.7 0.4 5.3 2.6 0.4 0 0.4 0.4 336 7 324 305 5 0 6 0 -9.4 0 -9.2 -9.6 03/24/2005 19:50:00 3.3 0.3 4.2 2.3 3.2 0.4 4.2 2.3 0.4 0 0.4 0.4 341 3 346 305 6 0 6 0 -9.5 0.1 -9.2 -9.8 03/24/2005 20:00:00 2.4 0.4 3 1.1 2 0.6 3 0.4 0.4 0 0.4 0.4 341 5 341 305 5 0 6 0 -9.7 0.1 -9.4 -10 03/24/2005 20:10:00 2 0.7 3.4 0.4 1.9 0.7 3.4 0.4 0.4 0 0.4 0.4 348 13 336 305 5 0 5 0 -9.8 0 -9.6 -10 03/24/2005 20:20:00 2.9 0.4 4.2 2.3 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 333 5 343 305 5 0 5 0 -9.3 0.2 -9 -9.8 03/24/2005 20:30:00 3.3 0.5 4.2 2.3 3.5 0.5 4.6 2.3 0.4 0 0.4 0.4 346 5 346 305 6 0 6 0 -8.9 0 -8.8 -9.2 03/24/2005 20:40:00 4 0.3 4.9 3 4.1 0.4 4.9 3 0.4 0 0.4 0.4 353 4 352 305 6 0 6 0 -8.8 0 -8.8 -9 03/24/2005 20:50:00 4.1 0.6 5.7 3 4.1 0.5 5.7 3 0.4 0 0.4 0.4 9 8 19 305 6 0 6 0 -9.3 0.1 -8.8 -9.6 03/24/2005 21:00:00 4.9 0.4 5.7 3.8 4.6 0.4 5.7 3.8 0.4 0 0.4 0.4 20 4 20 305 6 0 6 0 -9.7 0 -9.4 -9.8 03/24/2005 21:10:00 5.4 0.5 6.5 4.2 5.2 0.6 6.8 3.8 0.4 0 0.4 0.4 29 5 33 305 6 0 6 0 -9.7 0 -9.4 -9.8 03/24/2005 21:20:00 5.5 0.4 6.5 4.6 5.4 0.4 6.1 4.6 0.4 0 0.4 0.4 22 4 27 305 7 0 6 0 -9.4 0 -9.2 -9.6 03/24/2005 21:30:00 6.2 0.5 7.6 4.9 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 32 9 24 305 7 0 7 0 -9.7 0.1 -9.2 -10 03/24/2005 21:40:00 6 0.4 7.2 4.9 5.9 0.4 7.2 4.9 0.4 0 0.4 0.4 41 3 37 305 7 0 7 0 -10.2 0.2 -9.6 -10.7 03/24/2005 21:50:00 4.9 0.4 6.1 4.2 4.9 0.4 6.1 3.8 0.4 0 0.4 0.4 49 3 42 305 7 0 7 0 -11 0.2 -10.4 -11.3 03/24/2005 22:00:00 5.3 0.5 6.5 4.2 5.3 0.5 6.8 4.2 0.4 0 0.4 0.4 51 5 56 305 7 0 7 0 -11 0.2 -10.4 -11.3 03/24/2005 22:10:00 5.8 0.7 8 4.2 5.8 0.8 7.6 4.2 0.4 0 0.4 0.4 42 8 37 305 7 0 7 0 -10.1 0.2 -9.8 -10.4 03/24/2005 22:20:00 5.4 0.4 6.5 4.6 5.4 0.5 6.8 4.6 0.4 0 0.4 0.4 44 4 42 305 8 0 8 0 -9.9 0 -9.6 -10 03/24/2005 22:30:00 5.4 0.5 6.5 4.2 5.4 0.5 6.5 4.2 0.4 0 0.4 0.4 45 4 40 305 8 0 8 0 -10.2 0.1 -9.8 -10.7 03/24/2005 22:40:00 4.9 0.4 5.7 3.8 4.9 0.4 5.7 4.2 0.4 0 0.4 0.4 53 4 51 305 8 0 8 0 -10.8 0.1 -10.4 -11.1 03/24/2005 22:50:00 5 0.5 6.5 3.8 5 0.6 6.5 3.8 0.4 0 0.4 0.4 52 5 49 305 8 0 8 0 -10.9 0.1 -10.4 -11.3 03/24/2005 23:00:00 5 0.5 6.1 3.8 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 53 5 54 305 8 0 8 0 -10.5 0.1 -10.2 -10.9 03/24/2005 23:10:00 4 0.5 5.3 2.6 4 0.6 5.3 3 0.4 0 0.4 0.4 52 6 57 305 8 0 8 0 -10.4 0 -10.4 -10.7 03/24/2005 23:20:00 3.4 0.3 4.2 2.3 3.6 0.4 4.2 2.3 0.4 0 0.4 0.4 45 5 44 305 8 0 8 0 -10.5 0 -10.4 -10.9 03/24/2005 23:30:00 3 0.3 3.8 2.3 3.2 0.3 4.2 2.3 0.4 0 0.4 0.4 36 5 38 305 8 0 8 0 -10.8 0.1 -10.4 -11.1 03/24/2005 23:40:00 2.5 0.3 3 1.9 2.7 0.2 3.4 2.3 0.4 0 0.4 0.4 35 3 32 305 8 0 8 0 -11.1 0 -10.9 -11.3 03/24/2005 23:50:00 1.7 0.4 2.6 0.7 1.9 0.3 2.6 1.1 0.4 0 0.4 0.4 36 3 31 305 8 0 8 0 -11.1 0 -10.9 -11.3 03/25/2005 00:00:00 1 0.2 1.5 0.7 1.4 0.2 1.9 1.1 0.4 0 0.4 0.4 35 0 36 305 8 0 8 0 -11 0.1 -10.4 -11.3 03/25/2005 00:10:00 0.8 0.3 1.5 0.4 1.2 0.3 1.9 0.4 0.4 0 0.4 0.4 45 4 36 305 8 0 8 0 -10.8 0 -10.7 -10.9 03/25/2005 00:20:00 0.7 0.2 1.1 0.4 1.1 0.2 1.5 0.7 0.4 0 0.4 0.4 43 7 47 305 8 0 8 0 -10.7 0 -10.4 -10.9 03/25/2005 00:30:00 0.4 0.1 1.1 0.4 1 0.2 1.5 0.4 0.4 0 0.4 0.4 33 2 30 305 9 0 8 0 -10.5 0 -10.4 -10.7 03/25/2005 00:40:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 34 0 305 305 9 0 9 0 -10.5 0 -10.4 -10.7 03/25/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 9 0 0 0 -10.5 0 -10.4 -10.7 03/25/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 10 0 0 0 -10.4 0 -10 -10.7 03/25/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 10 0 0 0 -10.4 0 -10 -10.4 03/25/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 305 305 10 0 0 0 -10.3 0 -10 -10.4 03/25/2005 01:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 14 39 305 305 10 0 11 0 -10 0.1 -9.6 -10.2 03/25/2005 01:40:00 0.4 0.2 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 14 28 352 305 11 0 11 0 -9.8 0 -9.4 -10 03/25/2005 01:50:00 0.6 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 33 18 25 305 11 0 12 0 -9.4 0.1 -9.2 -9.6 03/25/2005 02:00:00 1.2 0.7 3 0.4 1.1 0.5 2.3 0.4 0.4 0 0.4 0.4 36 15 56 305 12 0 12 0 -9.1 0.1 -8.8 -9.4 03/25/2005 02:10:00 2.3 1 4.6 0.4 2.2 0.9 4.9 0.4 0.4 0 0.4 0.4 42 13 42 305 12 0 13 0 -8.5 0.1 -7.9 -8.8 03/25/2005 02:20:00 7.7 1.3 10.7 4.2 7.6 1.4 10.3 3.8 0.4 0 0.4 0.4 33 6 32 305 13 0 14 0 -7.6 0.2 -7.3 -8.2 03/25/2005 02:30:00 9.3 0.7 11.1 7.6 9.2 0.7 10.7 6.8 0.4 0 0.4 0.4 28 5 28 305 14 0 14 0 -7.7 0 -7.3 -7.9 03/25/2005 02:40:00 9.4 0.8 11.5 6.5 9.2 1 11.5 6.8 0.4 0 0.4 0.4 26 4 22 305 14 0 14 0 -7.8 0 -7.5 -8.2 03/25/2005 02:50:00 8.3 0.7 9.9 6.1 8.2 0.6 9.9 6.8 0.4 0 0.4 0.4 30 5 27 305 14 0 14 0 -7.9 0.1 -7.7 -8.2 03/25/2005 03:00:00 7.7 0.8 9.5 5.7 7.6 0.8 9.5 5.7 0.4 0 0.4 0.4 29 5 31 305 14 0 14 0 -8 0.1 -7.7 -8.2 03/25/2005 03:10:00 7.7 0.6 9.1 6.1 7.6 0.6 9.1 5.7 0.4 0 0.4 0.4 27 5 31 305 14 0 14 0 -8.2 0 -7.7 -8.2 03/25/2005 03:20:00 8.6 0.5 9.9 7.2 8.6 0.6 9.9 6.8 0.4 0 0.4 0.4 24 3 16 305 14 0 14 0 -8.3 0 -7.9 -8.6 03/25/2005 03:30:00 8.1 0.6 9.5 6.5 8.1 0.6 9.5 6.1 0.4 0 0.4 0.4 26 3 28 305 14 0 14 0 -8.4 0 -8.2 -8.6 03/25/2005 03:40:00 8.7 0.6 9.9 6.5 8.7 0.7 9.9 6.1 0.4 0 0.4 0.4 25 3 29 305 14 0 14 0 -8.6 0.1 -8.2 -8.8 03/25/2005 03:50:00 9 0.6 10.3 7.2 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 29 5 29 305 14 0 14 0 -8.6 0 -8.4 -8.8 03/25/2005 04:00:00 9.2 0.8 11.1 7.2 9.1 0.9 10.7 6.5 0.4 0 0.4 0.4 27 4 28 305 14 0 14 0 -8.8 0 -8.4 -9 03/25/2005 04:10:00 8.6 0.8 10.3 6.5 8.4 0.8 10.3 6.1 0.4 0 0.4 0.4 31 6 23 305 14 0 14 0 -8.9 0 -8.8 -9.2 03/25/2005 04:20:00 8.3 0.8 9.5 5.7 8.2 0.7 9.5 6.1 0.4 0 0.4 0.4 32 4 33 305 13 0 14 0 -9 0 -8.8 -9.2 03/25/2005 04:30:00 8.9 0.5 10.3 7.2 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 32 4 29 305 13 0 13 0 -9.1 0.1 -8.8 -9.2 03/25/2005 04:40:00 9 0.7 10.7 6.5 8.8 0.8 10.3 6.5 0.4 0 0.4 0.4 31 4 35 305 13 0 13 0 -9.1 0.1 -8.8 -9.2 03/25/2005 04:50:00 9.2 1 11.1 6.5 9.1 1 11.1 5.7 0.4 0 0.4 0.4 28 6 34 305 13 0 13 0 -9.1 0.1 -8.8 -9.2 03/25/2005 05:00:00 9.7 0.8 11.5 7.2 9.5 0.8 11.5 7.6 0.4 0 0.4 0.4 31 4 28 305 13 0 13 0 -9.3 0 -8.8 -9.4 03/25/2005 05:10:00 9.6 0.7 11.5 7.2 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 30 4 30 305 13 0 13 0 -9.3 0 -9.2 -9.4 03/25/2005 05:20:00 9.2 0.9 11.5 6.8 9 0.9 11.1 6.8 0.4 0 0.4 0.4 30 5 31 305 13 0 13 0 -9.4 0 -9.2 -9.6 03/25/2005 05:30:00 9.9 0.7 11.8 7.6 9.6 0.8 11.5 7.6 0.4 0 0.4 0.4 29 5 26 305 13 0 13 0 -9.5 0 -9.2 -9.6 03/25/2005 05:40:00 9 1 11.1 6.5 8.8 1 11.5 6.5 0.4 0 0.4 0.4 32 7 35 305 13 0 13 0 -9.7 0.1 -9.2 -9.8 03/25/2005 05:50:00 9.9 0.9 12.6 7.6 9.8 0.9 12.6 7.2 0.4 0 0.4 0.4 25 6 29 305 13 0 13 0 -9.8 0 -9.4 -10 03/25/2005 06:00:00 10.9 0.8 12.6 9.1 10.8 0.8 12.2 8 0.4 0 0.4 0.4 24 4 17 305 12 0 13 0 -10.1 0 -9.8 -10.2 03/25/2005 06:10:00 10 1.3 12.6 7.2 9.7 1.2 12.2 7.2 0.4 0 0.4 0.4 31 6 27 305 12 0 12 0 -10.1 0 -9.8 -10.4 03/25/2005 06:20:00 9.9 1.1 12.6 6.8 9.7 1.1 12.2 7.2 0.4 0 0.4 0.4 32 6 27 305 12 0 12 0 -10.1 0.1 -9.8 -10.4 03/25/2005 06:30:00 9.7 1 12.2 7.2 9.6 1 12.2 6.8 0.4 0 0.4 0.4 34 6 23 305 12 0 12 0 -10.3 0 -10 -10.4 03/25/2005 06:40:00 8.8 0.8 10.3 6.8 8.6 0.8 10.3 6.8 0.4 0 0.4 0.4 38 5 42 305 12 0 12 0 -10.5 0 -10.2 -10.9 03/25/2005 06:50:00 8.3 0.8 10.7 6.1 8.1 0.8 10.3 6.1 0.4 0 0.4 0.4 38 6 35 305 11 0 11 0 -10.8 0.1 -10.4 -10.9 03/25/2005 07:00:00 8.1 0.9 10.3 5.7 7.9 0.9 9.9 5.7 0.4 0 0.4 0.4 36 6 42 305 11 0 11 0 -10.9 0 -10.7 -11.1 03/25/2005 07:10:00 8.1 0.9 10.3 6.1 7.9 0.9 9.9 6.1 0.4 0 0.4 0.4 37 5 29 305 11 0 11 0 -10.9 0 -10.7 -10.9 03/25/2005 07:20:00 7.5 0.7 9.1 5.7 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 38 5 46 305 11 0 11 0 -11 0 -10.9 -11.1 03/25/2005 07:30:00 6.7 0.7 8.8 5.3 6.6 0.6 8.4 4.9 0.4 0 0.4 0.4 37 4 37 305 11 0 11 0 -11.1 0 -10.9 -11.3 03/25/2005 07:40:00 6.6 0.6 8.4 5.3 6.5 0.6 8.4 5.3 0.4 0 0.4 0.4 39 5 51 305 11 0 11 0 -10.9 0 -10.4 -11.3 03/25/2005 07:50:00 7.7 0.7 9.1 5.3 7.7 0.7 9.1 5.3 0.4 0 0.4 0.4 37 4 33 305 11 0 11 0 -10.7 0 -10.4 -10.9 03/25/2005 08:00:00 7.6 0.5 8.8 6.5 7.5 0.6 8.8 5.7 0.4 0 0.4 0.4 39 4 42 305 12 0 12 0 -10.4 0 -10.2 -10.7 03/25/2005 08:10:00 8 0.8 11.1 6.1 7.9 0.9 10.7 5.7 0.4 0 0.4 0.4 31 9 13 305 12 0 12 0 -10.2 0.1 -9.8 -10.4 03/25/2005 08:20:00 9.5 0.9 11.5 7.2 9.4 0.9 11.5 7.6 0.4 0 0.4 0.4 13 5 14 305 12 0 12 0 -10 0 -9.8 -10.2 03/25/2005 08:30:00 8.9 1 10.7 6.1 9 1 11.1 6.1 0.4 0 0.4 0.4 21 9 17 305 12 0 12 0 -10.1 0.1 -9.8 -10.4 03/25/2005 08:40:00 8.5 0.8 10.7 6.5 8.4 0.8 10.7 6.5 0.4 0 0.4 0.4 44 5 45 305 12 0 12 0 -10.7 0.2 -10 -10.9 03/25/2005 08:50:00 9 0.7 10.3 7.2 9 0.7 10.7 7.2 0.4 0 0.4 0.4 47 3 45 305 12 0 12 0 -10.9 0 -10.7 -11.3 03/25/2005 09:00:00 8.9 0.8 10.3 6.5 8.9 0.8 10.3 6.8 0.4 0 0.4 0.4 45 4 45 305 12 0 12 0 -10.9 0 -10.9 -11.3 03/25/2005 09:10:00 9.1 0.8 11.1 7.2 9.2 0.8 11.1 6.8 0.4 0 0.4 0.4 44 4 50 305 12 0 12 0 -11 0 -10.7 -11.3 03/25/2005 09:20:00 9.2 0.6 10.3 7.2 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 44 5 50 305 11 0 11 0 -11.2 0 -10.9 -11.5 03/25/2005 09:30:00 9.6 0.5 10.7 8 9.7 0.6 11.1 7.6 0.4 0 0.4 0.4 44 3 36 305 11 0 11 0 -11.4 0 -11.1 -11.5 03/25/2005 09:40:00 8.5 0.6 10.3 7.2 8.5 0.6 10.3 6.8 0.4 0 0.4 0.4 44 4 48 305 11 0 11 0 -11.3 0.1 -11.1 -11.5 03/25/2005 09:50:00 8.3 0.8 10.7 6.5 8.2 0.8 9.9 6.5 0.4 0 0.4 0.4 40 5 40 305 11 0 11 0 -11.3 0 -11.1 -11.5 03/25/2005 10:00:00 8.7 0.8 10.3 6.5 8.6 0.8 9.9 6.1 0.4 0 0.4 0.4 34 5 32 305 11 0 11 0 -11.2 0 -10.9 -11.5 03/25/2005 10:10:00 9 0.6 10.7 7.2 8.8 0.7 11.1 6.8 0.4 0 0.4 0.4 32 6 16 305 11 0 11 0 -11.1 0 -10.9 -11.3 03/25/2005 10:20:00 8.1 0.6 9.5 6.5 8 0.7 9.5 6.1 0.4 0 0.4 0.4 36 5 39 305 11 0 11 0 -11 0 -10.9 -11.3 03/25/2005 10:30:00 8 0.7 9.5 6.1 8 0.7 9.5 6.1 0.4 0 0.4 0.4 31 6 33 305 10 0 11 0 -11 0 -10.9 -11.3 03/25/2005 10:40:00 8.1 0.9 10.7 6.1 8 1 10.7 6.1 0.4 0 0.4 0.4 22 7 18 305 10 0 10 0 -11.2 0.1 -10.9 -11.5 03/25/2005 10:50:00 7.6 0.7 9.1 5.3 7.7 0.8 9.1 5.7 0.4 0 0.4 0.4 16 4 11 305 9 0 9 0 -11.3 0.1 -10.9 -11.7 03/25/2005 11:00:00 7.9 0.7 9.5 5.7 7.8 0.7 9.5 6.1 0.4 0 0.4 0.4 19 4 22 305 9 0 9 0 -11.7 0.1 -11.5 -11.9 03/25/2005 11:10:00 8.5 0.5 9.5 6.8 8.3 0.6 9.5 6.5 0.4 0 0.4 0.4 19 3 21 305 9 0 9 0 -11.7 0.1 -11.5 -11.9 03/25/2005 11:20:00 8.5 0.6 9.5 6.8 8.4 0.6 9.5 6.8 0.4 0 0.4 0.4 18 3 16 305 9 0 9 0 -11.7 0.1 -11.5 -12.1 03/25/2005 11:30:00 7.4 0.8 9.1 5.3 7.4 0.9 9.1 4.9 0.4 0 0.4 0.4 25 4 29 305 8 0 8 0 -11.7 0.1 -11.5 -11.9 03/25/2005 11:40:00 7.2 0.6 8.4 5.3 7.1 0.6 8.4 4.9 0.4 0 0.4 0.4 26 4 28 305 8 0 8 0 -11.6 0.1 -11.3 -11.9 03/25/2005 11:50:00 8.1 1 9.9 5.7 8 1.1 10.3 5.7 0.4 0 0.4 0.4 25 5 26 305 8 0 8 0 -11.2 0 -10.9 -11.5 03/25/2005 12:00:00 8.4 0.7 9.9 6.5 8.5 0.7 9.9 6.1 0.4 0 0.4 0.4 25 4 27 305 7 0 7 0 -11 0 -10.9 -11.3 03/25/2005 12:10:00 9.2 0.8 10.7 6.8 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 20 5 22 305 6 0 7 0 -11 0 -10.7 -11.1 03/25/2005 12:20:00 9.1 0.9 11.1 7.2 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 16 6 18 305 6 0 6 0 -10.9 0 -10.7 -11.3 03/25/2005 12:30:00 8.8 0.7 10.3 6.8 8.9 0.8 10.3 6.5 0.4 0 0.4 0.4 12 4 10 305 6 0 6 0 -11 0.2 -10.4 -11.5 03/25/2005 12:40:00 9.6 1 11.8 7.6 9.6 0.9 12.2 7.2 0.4 0 0.4 0.4 20 6 29 305 6 0 6 0 -11.1 0 -10.9 -11.5 03/25/2005 12:50:00 9.6 0.9 12.2 7.6 9.6 0.9 11.8 7.2 0.4 0 0.4 0.4 15 5 15 305 6 0 6 0 -11 0 -10.7 -11.3 03/25/2005 13:00:00 9.2 1 11.5 7.2 9.2 1 11.8 6.8 0.4 0 0.4 0.4 20 6 19 305 6 0 6 0 -10.8 0.1 -10.4 -11.3 03/25/2005 13:10:00 9.8 1.1 12.2 6.8 9.7 1.2 11.8 6.1 0.4 0 0.4 0.4 25 6 24 305 6 0 6 0 -10.7 0.1 -10.4 -10.9 03/25/2005 13:20:00 9.9 0.8 11.8 7.6 9.8 0.8 12.2 7.6 0.4 0 0.4 0.4 28 5 29 305 6 0 6 0 -10.9 0 -10.4 -11.1 03/25/2005 13:30:00 9.2 0.7 10.7 7.2 9.1 0.7 11.1 7.6 0.4 0 0.4 0.4 24 6 28 305 6 0 6 0 -10.8 0.1 -10.4 -10.9 03/25/2005 13:40:00 10.2 0.7 11.8 8.4 10.2 0.8 12.2 8.4 0.4 0 0.4 0.4 21 5 19 305 5 0 5 0 -10.9 0 -10.4 -11.1 03/25/2005 13:50:00 9.3 1 12.6 7.2 9.2 0.9 12.2 7.2 0.4 0 0.4 0.4 18 12 25 305 5 0 5 0 -10.8 0 -10.4 -10.9 03/25/2005 14:00:00 9.7 0.8 11.5 7.2 9.7 0.8 11.5 7.6 0.4 0 0.4 0.4 5 5 5 305 5 0 5 0 -10.9 0 -10.4 -11.3 03/25/2005 14:10:00 9.8 0.7 11.8 8 9.8 0.8 11.8 7.2 0.4 0 0.4 0.4 7 5 8 305 5 0 5 0 -11.1 0.1 -10.7 -11.3 03/25/2005 14:20:00 9.3 0.8 11.1 6.8 9.4 0.7 11.1 7.2 0.4 0 0.4 0.4 11 5 7 305 5 0 5 0 -11.1 0.1 -10.7 -11.3 03/25/2005 14:30:00 9.2 0.8 11.1 6.8 9.3 0.9 11.8 6.5 0.4 0 0.4 0.4 12 5 7 305 5 0 5 0 -10.9 0 -10.7 -11.1 03/25/2005 14:40:00 10.1 0.9 11.8 7.6 10.1 0.9 11.8 7.6 0.4 0 0.4 0.4 12 4 16 305 5 0 5 0 -10.7 0.1 -10.2 -10.9 03/25/2005 14:50:00 9.8 0.8 11.1 7.2 9.8 0.8 11.5 7.2 0.4 0 0.4 0.4 13 5 9 305 5 0 6 0 -10.4 0.1 -9.8 -10.7 03/25/2005 15:00:00 8.9 0.8 11.1 6.1 8.9 0.8 11.1 6.8 0.4 0 0.4 0.4 11 5 2 305 5 0 6 0 -10.3 0 -10 -10.4 03/25/2005 15:10:00 8.6 0.7 9.9 6.8 8.5 0.8 9.9 6.5 0.4 0 0.4 0.4 8 6 5 305 5 0 5 0 -10.3 0.1 -9.8 -10.4 03/25/2005 15:20:00 8.7 0.6 10.7 6.8 8.8 0.7 10.7 6.5 0.4 0 0.4 0.4 8 5 11 305 5 0 5 0 -10.2 0.1 -9.8 -10.4 03/25/2005 15:30:00 8.4 0.8 10.7 6.5 8.4 0.9 11.1 6.1 0.4 0 0.4 0.4 11 5 17 305 5 0 5 0 -10.1 0 -9.8 -10.2 03/25/2005 15:40:00 9.1 0.8 10.7 6.5 9.1 0.8 11.1 7.2 0.4 0 0.4 0.4 18 5 25 305 4 0 4 0 -10.1 0 -9.8 -10.4 03/25/2005 15:50:00 8.6 0.6 10.3 6.8 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 14 4 15 305 4 0 4 0 -10.1 0 -9.8 -10.2 03/25/2005 16:00:00 8.1 0.7 9.9 6.1 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 14 5 15 305 4 0 4 0 -10 0 -9.6 -10.2 03/25/2005 16:10:00 8.2 0.8 9.5 5.7 8.2 0.8 9.9 5.7 0.4 0 0.4 0.4 11 4 8 305 4 0 4 0 -10 0.1 -9.6 -10.4 03/25/2005 16:20:00 8.6 0.7 10.3 6.5 8.6 0.8 10.7 6.1 0.4 0 0.4 0.4 7 4 1 305 4 0 4 0 -10.2 0.1 -9.8 -10.4 03/25/2005 16:30:00 8.9 0.9 11.5 6.8 8.9 1 11.8 6.8 0.4 0 0.4 0.4 7 4 5 305 5 0 5 0 -9.7 0.1 -9.2 -10 03/25/2005 16:40:00 9.6 0.8 11.8 7.6 9.6 0.9 11.8 7.6 0.4 0 0.4 0.4 8 4 8 305 5 0 5 0 -10 0 -9.6 -10.2 03/25/2005 16:50:00 9.6 0.6 10.7 8 9.7 0.6 11.5 7.6 0.4 0 0.4 0.4 1 4 358 305 4 0 4 0 -10.1 0 -9.8 -10.2 03/25/2005 17:00:00 9.1 0.9 10.7 6.8 9.1 1 11.1 6.5 0.4 0 0.4 0.4 9 4 6 305 4 0 4 0 -10.1 0.1 -9.8 -10.4 03/25/2005 17:10:00 9.1 1 11.1 6.5 9.1 1 11.1 6.5 0.4 0 0.4 0.4 8 7 22 305 5 0 5 0 -10.1 0 -9.8 -10.4 03/25/2005 17:20:00 9.3 0.9 11.1 6.5 9.1 1 11.5 6.8 0.4 0 0.4 0.4 16 5 13 305 5 0 5 0 -10.2 0 -10 -10.4 03/25/2005 17:30:00 9.2 0.8 11.1 6.5 9.1 0.8 11.1 6.8 0.4 0 0.4 0.4 21 5 29 305 6 0 6 0 -10.3 0 -10 -10.4 03/25/2005 17:40:00 9.9 1 11.8 7.6 9.9 1 12.2 7.6 0.4 0 0.4 0.4 15 5 19 305 6 0 6 0 -10.3 0 -10 -10.4 03/25/2005 17:50:00 9.3 0.8 10.7 6.8 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 19 5 18 305 6 0 6 0 -10.3 0 -10 -10.4 03/25/2005 18:00:00 9.7 0.7 11.1 8 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 17 5 13 305 7 0 7 0 -10.4 0 -10 -10.7 03/25/2005 18:10:00 10.5 0.7 11.8 8.4 10.4 0.8 12.2 8.4 0.4 0 0.4 0.4 16 3 20 305 7 0 7 0 -10.5 0 -10.4 -10.9 03/25/2005 18:20:00 9.6 0.8 11.8 7.2 9.6 0.8 11.8 7.6 0.4 0 0.4 0.4 16 5 15 305 7 0 7 0 -10.5 0 -10.4 -10.9 03/25/2005 18:30:00 8.8 0.7 10.7 6.1 8.8 0.8 10.7 6.5 0.4 0 0.4 0.4 19 5 23 305 8 0 8 0 -10.5 0 -10.2 -10.7 03/25/2005 18:40:00 8.8 1 11.5 6.5 8.7 1 11.5 6.5 0.4 0 0.4 0.4 14 6 10 305 8 0 8 0 -10.4 0 -10.2 -10.7 03/25/2005 18:50:00 8.7 1.1 10.7 6.1 8.6 1.2 10.7 5.7 0.4 0 0.4 0.4 15 5 19 305 8 0 8 0 -10.5 0 -10.4 -10.9 03/25/2005 19:00:00 9.8 1 11.8 7.2 9.7 1 11.8 7.6 0.4 0 0.4 0.4 14 5 13 305 8 0 8 0 -10.7 0.1 -10.4 -10.9 03/25/2005 19:10:00 9.7 0.8 11.8 6.8 9.6 1 11.8 6.8 0.4 0 0.4 0.4 21 5 23 305 8 0 8 0 -10.8 0 -10.4 -10.9 03/25/2005 19:20:00 9.5 0.9 11.5 7.2 9.4 0.9 11.5 6.8 0.4 0 0.4 0.4 18 6 21 305 9 0 8 0 -10.8 0.1 -10.4 -11.1 03/25/2005 19:30:00 9.3 1 11.5 6.1 9.2 1.1 11.5 6.1 0.4 0 0.4 0.4 14 5 13 305 8 0 8 0 -11.1 0.1 -10.9 -11.3 03/25/2005 19:40:00 9.6 0.8 11.8 7.2 9.6 0.9 11.5 7.2 0.4 0 0.4 0.4 12 5 17 305 8 0 8 0 -11.2 0 -10.9 -11.3 03/25/2005 19:50:00 9.6 1 11.8 7.2 9.4 1 11.8 7.2 0.4 0 0.4 0.4 14 5 14 305 8 0 8 0 -11.1 0 -10.9 -11.3 03/25/2005 20:00:00 9.5 0.9 11.8 7.2 9.5 1 11.8 6.8 0.4 0 0.4 0.4 11 4 10 305 8 0 8 0 -11.1 0 -10.9 -11.3 03/25/2005 20:10:00 9.3 0.7 11.1 6.8 9.3 0.8 11.1 7.2 0.4 0 0.4 0.4 12 5 11 305 8 0 8 0 -11 0 -10.9 -11.3 03/25/2005 20:20:00 9.8 0.8 11.5 7.6 9.7 0.8 11.5 7.6 0.4 0 0.4 0.4 18 4 21 305 9 0 8 0 -11.1 0 -10.9 -11.3 03/25/2005 20:30:00 9.2 0.9 11.5 6.5 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 17 4 19 305 9 0 8 0 -11 0 -10.9 -11.3 03/25/2005 20:40:00 9.1 1 11.1 6.5 9 1 11.1 6.5 0.4 0 0.4 0.4 14 5 20 305 9 0 9 0 -11 0 -10.9 -11.3 03/25/2005 20:50:00 8.6 0.8 10.3 6.8 8.6 0.8 10.3 6.5 0.4 0 0.4 0.4 13 5 14 305 9 0 9 0 -11 0 -10.9 -11.3 03/25/2005 21:00:00 9.2 0.7 10.7 7.2 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 15 3 18 305 9 0 9 0 -11 0 -10.9 -11.3 03/25/2005 21:10:00 8.4 0.8 10.3 6.1 8.4 0.9 10.3 6.1 0.4 0 0.4 0.4 16 4 17 305 9 0 9 0 -11 0 -10.9 -11.3 03/25/2005 21:20:00 8.7 0.6 9.9 6.8 8.7 0.6 9.9 6.8 0.4 0 0.4 0.4 16 4 19 305 9 0 9 0 -11 0 -10.9 -11.1 03/25/2005 21:30:00 8.2 0.7 9.5 6.5 8.1 0.8 9.5 6.1 0.4 0 0.4 0.4 9 5 8 305 9 0 9 0 -10.9 0 -10.7 -11.1 03/25/2005 21:40:00 7.8 0.7 9.1 6.1 7.8 0.7 9.1 6.1 0.4 0 0.4 0.4 7 4 4 305 9 0 9 0 -10.7 0 -10.4 -10.9 03/25/2005 21:50:00 8.6 0.8 10.3 6.5 8.5 0.8 9.9 6.5 0.4 0 0.4 0.4 10 4 7 305 9 0 9 0 -10.7 0 -10.4 -10.9 03/25/2005 22:00:00 8.7 0.8 10.7 6.5 8.6 0.8 10.7 6.5 0.4 0 0.4 0.4 13 5 10 305 9 0 9 0 -10.8 0 -10.4 -10.9 03/25/2005 22:10:00 7.9 0.8 9.9 6.1 8 0.9 9.9 6.1 0.4 0 0.4 0.4 16 4 12 305 10 0 9 0 -10.7 0 -10.4 -10.9 03/25/2005 22:20:00 8.7 0.9 10.7 6.1 8.5 0.9 11.1 6.1 0.4 0 0.4 0.4 13 4 16 305 10 0 10 0 -10.5 0 -10.4 -10.9 03/25/2005 22:30:00 9.2 0.7 11.1 6.8 9.2 0.8 11.1 6.8 0.4 0 0.4 0.4 13 4 18 305 10 0 10 0 -10.8 0 -10.4 -10.9 03/25/2005 22:40:00 9.1 0.7 10.7 6.8 9 0.8 10.7 6.5 0.4 0 0.4 0.4 9 3 8 305 10 0 10 0 -10.6 0 -10.4 -10.9 03/25/2005 22:50:00 9.7 0.8 11.5 7.2 9.7 0.8 11.5 7.2 0.4 0 0.4 0.4 13 3 11 305 10 0 10 0 -10.7 0 -10.4 -10.9 03/25/2005 23:00:00 9.7 0.7 11.1 7.6 9.6 0.8 11.5 7.6 0.4 0 0.4 0.4 11 4 13 305 10 0 10 0 -10.6 0 -10.4 -10.9 03/25/2005 23:10:00 9.7 0.9 11.5 6.5 9.7 1 11.8 7.2 0.4 0 0.4 0.4 11 4 10 305 10 0 10 0 -10.7 0 -10.4 -10.9 03/25/2005 23:20:00 9.2 1 11.8 7.2 9.1 1 11.8 6.8 0.4 0 0.4 0.4 12 4 13 305 10 0 11 0 -10.7 0 -10.4 -10.9 03/25/2005 23:30:00 9.4 0.8 11.1 7.2 9.4 0.8 11.1 7.2 0.4 0 0.4 0.4 10 5 12 305 11 0 10 0 -10.5 0 -10.4 -10.9 03/25/2005 23:40:00 9.3 0.8 11.1 7.2 9.1 0.9 10.7 7.2 0.4 0 0.4 0.4 11 5 13 305 11 0 11 0 -10.7 0.1 -10.4 -10.9 03/25/2005 23:50:00 9.6 0.9 11.1 7.2 9.6 0.9 11.5 7.6 0.4 0 0.4 0.4 10 4 13 305 11 0 11 0 -10.7 0 -10.4 -10.9 03/26/2005 00:00:00 9.3 1 11.1 6.8 9.2 1 11.1 6.8 0.4 0 0.4 0.4 6 4 12 305 11 0 11 0 -10.6 0 -10.4 -10.9 03/26/2005 00:10:00 9.6 0.7 11.1 6.8 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 9 3 8 305 11 0 11 0 -10.5 0 -10.4 -10.9 03/26/2005 00:20:00 9.3 0.9 11.1 6.8 9.3 0.9 11.1 7.2 0.4 0 0.4 0.4 12 4 11 305 11 0 11 0 -10.5 0 -10.2 -10.7 03/26/2005 00:30:00 9 0.8 10.7 7.6 9.1 0.8 10.7 7.2 0.4 0 0.4 0.4 13 4 3 305 11 0 11 0 -10.4 0 -10 -10.7 03/26/2005 00:40:00 9.3 0.9 11.1 7.2 9.3 0.9 11.5 6.8 0.4 0 0.4 0.4 12 5 8 305 11 0 11 0 -10.4 0 -10.2 -10.4 03/26/2005 00:50:00 9.1 0.8 10.7 6.8 9.1 0.8 11.1 6.8 0.4 0 0.4 0.4 9 5 6 305 11 0 11 0 -10.4 0 -10 -10.4 03/26/2005 01:00:00 9.8 0.8 11.5 7.2 9.8 0.9 11.8 7.2 0.4 0 0.4 0.4 11 3 12 305 11 0 11 0 -10.4 0 -10.4 -10.4 03/26/2005 01:10:00 9.2 0.8 11.1 6.5 9.1 0.8 11.1 6.5 0.4 0 0.4 0.4 13 4 9 305 11 0 11 0 -10.4 0 -10 -10.7 03/26/2005 01:20:00 9.2 0.9 12.2 7.2 9.2 1 11.8 6.8 0.4 0 0.4 0.4 11 4 7 305 11 0 11 0 -10.3 0 -10 -10.4 03/26/2005 01:30:00 9.5 0.8 11.5 7.6 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 11 3 8 305 11 0 11 0 -10.3 0 -10 -10.4 03/26/2005 01:40:00 9.2 0.9 11.1 6.8 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 12 4 14 305 11 0 11 0 -10.2 0.1 -9.8 -10.4 03/26/2005 01:50:00 9 0.9 10.7 6.5 8.9 0.8 11.1 6.8 0.4 0 0.4 0.4 10 4 9 305 11 0 11 0 -10.1 0.1 -9.8 -10.4 03/26/2005 02:00:00 9.4 0.8 11.5 6.8 9.3 0.9 11.8 7.2 0.4 0 0.4 0.4 10 5 7 305 11 0 11 0 -10.1 0.1 -9.8 -10.4 03/26/2005 02:10:00 9.6 0.6 11.1 7.6 9.6 0.6 11.1 8 0.4 0 0.4 0.4 9 3 9 305 11 0 11 0 -10.1 0.1 -9.8 -10.4 03/26/2005 02:20:00 9 0.8 10.7 6.5 9 0.8 10.7 6.1 0.4 0 0.4 0.4 8 3 8 305 11 0 11 0 -10 0 -9.6 -10.2 03/26/2005 02:30:00 9.2 0.8 10.7 7.2 9.2 0.8 11.1 7.2 0.4 0 0.4 0.4 9 3 5 305 12 0 12 0 -10 0 -9.6 -10 03/26/2005 02:40:00 8.6 0.9 10.7 6.8 8.7 0.9 10.7 6.8 0.4 0 0.4 0.4 9 4 11 305 12 0 12 0 -9.9 0 -9.6 -10 03/26/2005 02:50:00 9.6 0.9 11.5 7.2 9.6 0.9 11.8 7.2 0.4 0 0.4 0.4 15 6 9 305 12 0 12 0 -9.8 0 -9.4 -10 03/26/2005 03:00:00 10.7 0.9 12.6 8.4 10.7 1 13 8.8 0.4 0 0.4 0.4 21 4 21 305 12 0 12 0 -9.8 0 -9.4 -10 03/26/2005 03:10:00 10.3 1.1 12.6 8 10.1 1 12.6 7.6 0.4 0 0.4 0.4 21 5 18 305 12 0 12 0 -9.8 0 -9.6 -10 03/26/2005 03:20:00 10.4 1.1 12.6 7.6 10.4 1.1 12.2 7.6 0.4 0 0.4 0.4 21 4 22 305 12 0 12 0 -9.8 0 -9.6 -10 03/26/2005 03:30:00 10 0.9 12.2 7.6 10 0.9 12.2 7.2 0.4 0 0.4 0.4 20 5 17 305 12 0 12 0 -9.8 0 -9.6 -10 03/26/2005 03:40:00 10.6 1 12.6 8 10.5 1 13 8 0.4 0 0.4 0.4 20 5 20 305 12 0 12 0 -9.9 0 -9.6 -10 03/26/2005 03:50:00 9.9 1.1 12.2 7.6 9.8 1.1 12.2 7.2 0.4 0 0.4 0.4 20 4 23 305 12 0 12 0 -9.9 0 -9.6 -10 03/26/2005 04:00:00 10.7 0.8 12.2 8 10.6 0.8 12.2 8.4 0.4 0 0.4 0.4 19 4 22 305 12 0 12 0 -9.9 0 -9.6 -10 03/26/2005 04:10:00 10.4 1 12.2 8 10.3 1 12.6 7.6 0.4 0 0.4 0.4 17 4 21 305 12 0 12 0 -9.9 0 -9.6 -10 03/26/2005 04:20:00 10.2 1 12.6 8 10.2 1.1 13 7.6 0.4 0 0.4 0.4 20 5 18 305 12 0 12 0 -9.9 0 -9.6 -10 03/26/2005 04:30:00 11.5 0.7 13 9.5 11.3 0.8 13 9.1 0.4 0 0.4 0.4 21 4 22 305 12 0 12 0 -9.8 0 -9.6 -10 03/26/2005 04:40:00 11.3 0.9 13.7 8.8 11.2 0.9 13.7 8.4 0.4 0 0.4 0.4 21 5 21 305 12 0 12 0 -9.8 0 -9.6 -10 03/26/2005 04:50:00 11.2 1.1 13 7.6 11 1.1 13.3 8.4 0.4 0 0.4 0.4 21 5 16 305 12 0 12 0 -9.8 0 -9.4 -9.8 03/26/2005 05:00:00 11.3 1 13 8.8 11.1 1 13 8.4 0.4 0 0.4 0.4 20 5 16 305 12 0 12 0 -9.8 0 -9.4 -9.8 03/26/2005 05:10:00 11.6 0.9 13.3 8.4 11.5 0.9 13.3 8.8 0.4 0 0.4 0.4 19 4 19 305 12 0 12 0 -9.8 0 -9.6 -10 03/26/2005 05:20:00 11.8 1.1 14.1 8.8 11.5 1.1 14.1 8.4 0.4 0 0.4 0.4 19 4 21 305 12 0 12 0 -9.8 0 -9.4 -10 03/26/2005 05:30:00 11.3 1 13.3 8.8 11.2 1.1 13.7 8 0.4 0 0.4 0.4 17 4 17 305 12 0 12 0 -9.8 0.1 -9.4 -10 03/26/2005 05:40:00 12 1 14.1 9.1 11.8 1 14.5 8.8 0.4 0 0.4 0.4 19 5 21 305 12 0 12 0 -9.8 0 -9.4 -10 03/26/2005 05:50:00 12.2 1 14.1 9.1 12.1 1 14.1 9.5 0.4 0 0.4 0.4 21 4 24 305 12 0 13 0 -9.8 0 -9.6 -10 03/26/2005 06:00:00 12.4 0.8 14.5 9.9 12.2 0.9 14.5 9.9 0.4 0 0.4 0.4 18 4 18 305 12 0 12 0 -9.8 0 -9.6 -10 03/26/2005 06:10:00 12.2 0.7 13.3 9.5 12 0.8 14.1 9.1 0.4 0 0.4 0.4 21 4 22 305 12 0 13 0 -9.8 0 -9.4 -9.8 03/26/2005 06:20:00 10.9 1 13 7.6 10.7 1.1 13.3 7.6 0.4 0 0.4 0.4 21 5 24 305 13 0 13 0 -9.7 0 -9.4 -9.8 03/26/2005 06:30:00 10.5 1 12.6 7.6 10.3 1 12.6 7.6 0.4 0 0.4 0.4 19 5 21 305 13 0 13 0 -9.7 0.1 -9.2 -9.8 03/26/2005 06:40:00 10.3 1 13 8 10.1 1 13 8 0.4 0 0.4 0.4 21 5 24 305 13 0 13 0 -9.6 0 -9.2 -9.8 03/26/2005 06:50:00 9.8 1 11.8 7.6 9.8 1.1 12.2 7.2 0.4 0 0.4 0.4 21 4 23 305 13 0 13 0 -9.5 0 -9.2 -9.6 03/26/2005 07:00:00 9.6 1 12.2 7.2 9.5 1 11.5 7.2 0.4 0 0.4 0.4 21 4 25 305 13 0 13 0 -9.3 0 -9 -9.6 03/26/2005 07:10:00 10 0.8 11.5 7.6 9.9 0.9 11.8 7.2 0.4 0 0.4 0.4 25 6 21 305 14 0 13 0 -9.3 0 -8.8 -9.4 03/26/2005 07:20:00 9.5 0.7 11.1 7.6 9.3 0.7 11.5 7.6 0.4 0 0.4 0.4 33 4 35 305 14 0 14 0 -9.1 0.1 -8.8 -9.2 03/26/2005 07:30:00 9 0.7 10.7 6.5 8.9 0.7 10.7 6.8 0.4 0 0.4 0.4 34 4 39 305 14 0 14 0 -9 0 -8.8 -9.2 03/26/2005 07:40:00 8.2 1 10.3 5.7 8.1 1 10.3 5.3 0.4 0 0.4 0.4 35 5 39 305 14 0 14 0 -9 0 -8.8 -9.2 03/26/2005 07:50:00 8.4 0.8 9.5 6.1 8.2 0.8 9.9 6.1 0.4 0 0.4 0.4 32 5 33 305 14 0 14 0 -9 0 -8.8 -9.2 03/26/2005 08:00:00 8.4 0.7 9.9 6.5 8.2 0.6 9.5 6.8 0.4 0 0.4 0.4 30 4 25 305 14 0 14 0 -9.1 0.1 -8.8 -9.2 03/26/2005 08:10:00 8.7 0.8 10.3 6.1 8.5 0.8 10.3 6.1 0.4 0 0.4 0.4 30 3 30 305 14 0 14 0 -9.1 0.1 -8.8 -9.2 03/26/2005 08:20:00 8.6 0.8 10.3 6.8 8.4 0.8 9.9 6.1 0.4 0 0.4 0.4 32 3 40 305 15 0 14 0 -9.1 0.1 -8.8 -9.2 03/26/2005 08:30:00 8.1 0.7 9.9 6.1 8.1 0.7 9.5 6.5 0.4 0 0.4 0.4 32 4 31 305 15 0 15 0 -9.1 0.1 -8.8 -9.2 03/26/2005 08:40:00 8.7 0.6 10.3 7.2 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 32 4 32 305 15 0 15 0 -9.1 0 -8.8 -9.2 03/26/2005 08:50:00 8.1 0.8 9.9 5.7 7.9 0.8 9.9 5.7 0.4 0 0.4 0.4 31 5 29 305 15 0 15 0 -9.1 0 -8.8 -9.2 03/26/2005 09:00:00 8.1 0.8 9.9 6.1 7.9 0.8 9.5 6.1 0.4 0 0.4 0.4 32 5 33 305 15 0 15 0 -9 0 -8.8 -9.2 03/26/2005 09:10:00 9.6 0.8 11.5 6.8 9.4 0.9 11.1 6.1 0.4 0 0.4 0.4 31 3 33 305 15 0 15 0 -9 0 -8.8 -9.2 03/26/2005 09:20:00 9.9 0.8 11.5 7.2 9.7 0.8 11.5 7.2 0.4 0 0.4 0.4 34 4 27 305 15 0 15 0 -9.1 0.1 -8.8 -9.2 03/26/2005 09:30:00 9.4 0.7 11.1 7.6 9.1 0.7 11.1 7.2 0.4 0 0.4 0.4 35 6 29 305 15 0 15 0 -9.2 0 -8.8 -9.2 03/26/2005 09:40:00 9.6 0.8 11.5 7.6 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 31 4 37 305 15 0 15 0 -9.3 0 -9 -9.4 03/26/2005 09:50:00 9.2 0.7 10.7 7.6 9 0.7 11.1 6.8 0.4 0 0.4 0.4 34 4 33 305 15 0 15 0 -9.5 0 -9.2 -9.6 03/26/2005 10:00:00 9.6 0.8 11.5 7.6 9.3 0.8 11.5 7.6 0.4 0 0.4 0.4 33 4 33 305 15 0 15 0 -9.6 0 -9.4 -9.6 03/26/2005 10:10:00 9.3 0.7 11.1 7.2 9 0.7 11.1 7.2 0.4 0 0.4 0.4 36 4 37 305 15 0 15 0 -9.5 0 -9.2 -9.6 03/26/2005 10:20:00 9.4 0.8 11.5 7.6 9.1 0.8 11.1 7.2 0.4 0 0.4 0.4 36 5 37 305 15 0 15 0 -9.7 0.1 -9.2 -9.8 03/26/2005 10:30:00 9 0.8 10.7 6.8 8.8 0.8 10.7 6.8 0.4 0 0.4 0.4 35 4 40 305 15 0 15 0 -9.7 0 -9.4 -9.8 03/26/2005 10:40:00 8.6 0.7 9.9 6.8 8.4 0.7 10.7 6.8 0.4 0 0.4 0.4 37 5 31 305 15 0 15 0 -9.8 0 -9.4 -10 03/26/2005 10:50:00 9 0.7 10.7 7.2 8.7 0.7 10.7 7.2 0.4 0 0.4 0.4 39 4 38 305 14 0 14 0 -9.9 0 -9.6 -10 03/26/2005 11:00:00 9.4 0.6 11.1 8 9.1 0.6 10.7 7.6 0.4 0 0.4 0.4 35 5 37 305 14 0 14 0 -9.7 0.1 -9.2 -10 03/26/2005 11:10:00 9.4 0.7 10.7 7.6 9.2 0.7 10.7 7.2 0.4 0 0.4 0.4 31 4 27 305 15 0 15 0 -9.3 0.1 -8.8 -9.6 03/26/2005 11:20:00 8.6 0.7 10.7 6.8 8.3 0.9 10.3 6.1 0.4 0 0.4 0.4 26 4 27 305 15 0 15 0 -9.5 0.2 -9 -9.8 03/26/2005 11:30:00 8.8 0.6 10.3 6.8 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 24 3 22 305 15 0 14 0 -9.8 0 -9.4 -10 03/26/2005 11:40:00 9.2 0.7 10.7 7.6 9 0.8 10.7 7.2 0.4 0 0.4 0.4 25 3 25 305 14 0 14 0 -9.8 0 -9.6 -10 03/26/2005 11:50:00 8.5 0.9 10.7 6.1 8.3 0.9 10.7 6.1 0.4 0 0.4 0.4 27 4 31 305 16 0 16 0 -9.7 0.1 -9.2 -9.8 03/26/2005 12:00:00 9.3 0.7 11.1 7.2 9 0.7 10.7 7.2 0.4 0 0.4 0.4 28 4 29 305 16 0 16 0 -9.7 0.1 -9.2 -9.8 03/26/2005 12:10:00 9.1 0.6 10.3 7.2 8.9 0.6 10.7 7.2 0.4 0 0.4 0.4 26 3 26 305 15 0 15 0 -9.4 0.1 -8.8 -9.6 03/26/2005 12:20:00 8.2 0.8 10.3 6.5 8 0.8 10.3 6.1 0.4 0 0.4 0.4 29 5 24 305 16 0 16 0 -9.1 0.1 -8.8 -9.2 03/26/2005 12:30:00 8.1 0.6 9.1 6.5 8 0.6 9.1 6.5 0.4 0 0.4 0.4 33 4 34 305 15 0 15 0 -9.3 0 -8.8 -9.4 03/26/2005 12:40:00 8.1 0.8 9.9 6.1 7.9 0.8 9.9 6.1 0.4 0 0.4 0.4 30 4 30 305 15 0 15 0 -9.1 0.1 -8.8 -9.4 03/26/2005 12:50:00 8.9 1 11.1 6.8 8.7 1.1 11.1 6.1 0.4 0 0.4 0.4 27 5 27 305 14 0 14 0 -9.3 0 -8.8 -9.6 03/26/2005 13:00:00 9.4 0.7 11.1 7.2 9.3 0.8 11.1 7.2 0.4 0 0.4 0.4 25 4 27 305 13 0 14 0 -9.4 0 -9.2 -9.6 03/26/2005 13:10:00 9.3 0.7 10.7 7.2 9.1 0.8 10.7 6.8 0.4 0 0.4 0.4 29 4 36 305 13 0 13 0 -9.3 0 -9 -9.4 03/26/2005 13:20:00 9.4 0.6 10.7 7.6 9.2 0.7 11.1 7.6 0.4 0 0.4 0.4 29 4 30 305 13 0 13 0 -9.3 0 -9 -9.4 03/26/2005 13:30:00 9.1 0.8 10.7 6.5 9 0.8 10.7 6.5 0.4 0 0.4 0.4 29 4 38 305 13 0 13 0 -9.1 0.1 -8.8 -9.4 03/26/2005 13:40:00 9.1 1.1 10.7 6.5 9 1.1 11.1 6.5 0.4 0 0.4 0.4 29 5 27 305 13 0 13 0 -9 0.1 -8.6 -9.2 03/26/2005 13:50:00 9.2 0.8 11.1 7.2 9 0.8 10.7 6.8 0.4 0 0.4 0.4 27 4 21 305 13 0 13 0 -9 0 -8.6 -9.2 03/26/2005 14:00:00 8.8 0.9 10.7 6.5 8.6 1 11.1 6.1 0.4 0 0.4 0.4 32 5 37 305 12 0 12 0 -8.8 0 -8.4 -9.2 03/26/2005 14:10:00 8.9 0.8 10.7 6.1 8.8 0.8 10.7 6.1 0.4 0 0.4 0.4 33 4 31 305 12 1 12 0 -9.1 0.2 -8.4 -9.4 03/26/2005 14:20:00 8.6 0.7 9.9 6.5 8.5 0.7 9.9 6.5 0.4 0 0.4 0.4 32 4 33 305 10 0 10 0 -9.4 0 -9 -9.6 03/26/2005 14:30:00 8.9 0.8 10.3 6.8 8.9 0.8 10.7 6.5 0.4 0 0.4 0.4 24 4 22 305 10 0 9 0 -9.4 0 -9 -9.6 03/26/2005 14:40:00 9.1 0.7 10.7 6.8 8.9 0.7 11.1 6.8 0.4 0 0.4 0.4 25 5 30 305 9 0 9 0 -9.6 0 -9.2 -9.8 03/26/2005 14:50:00 8.7 0.8 10.3 6.1 8.6 0.8 10.7 6.1 0.4 0 0.4 0.4 28 5 21 305 9 0 9 0 -9.3 0.2 -8.8 -9.6 03/26/2005 15:00:00 8.4 0.5 9.9 6.8 8.3 0.6 9.5 6.8 0.4 0 0.4 0.4 29 4 31 305 10 0 10 0 -8.9 0 -8.6 -9.2 03/26/2005 15:10:00 8.6 0.6 9.5 6.8 8.6 0.6 9.5 6.1 0.4 0 0.4 0.4 19 4 17 305 9 1 9 0 -9.1 0.2 -8.6 -9.4 03/26/2005 15:20:00 8.3 0.7 9.5 5.7 8.2 0.8 9.5 6.1 0.4 0 0.4 0.4 18 5 19 305 8 0 8 0 -9.1 0.1 -8.8 -9.4 03/26/2005 15:30:00 7.6 0.8 9.5 5.7 7.5 0.8 9.5 5.7 0.4 0 0.4 0.4 21 5 21 305 8 0 8 0 -9.1 0.1 -8.8 -9.2 03/26/2005 15:40:00 7.9 0.7 9.5 6.5 7.8 0.7 9.5 6.1 0.4 0 0.4 0.4 31 7 30 305 8 0 8 0 -9.2 0 -8.8 -9.4 03/26/2005 15:50:00 8.2 0.6 9.5 6.5 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 37 4 40 305 8 0 8 0 -9.4 0 -9.2 -9.6 03/26/2005 16:00:00 8.5 0.5 9.5 7.2 8.4 0.6 9.5 6.8 0.4 0 0.4 0.4 36 4 35 305 7 0 7 0 -9.4 0 -9.2 -9.6 03/26/2005 16:10:00 8.6 0.7 10.7 6.8 8.4 0.8 10.7 6.5 0.4 0 0.4 0.4 29 8 21 305 7 0 7 0 -9.4 0 -9.2 -9.4 03/26/2005 16:20:00 8.8 0.8 10.7 6.8 8.7 0.8 10.7 6.5 0.4 0 0.4 0.4 29 4 25 305 7 0 7 0 -9.3 0 -9 -9.6 03/26/2005 16:30:00 9.1 0.5 10.3 7.2 9.1 0.6 10.7 7.2 0.4 0 0.4 0.4 32 5 30 305 7 0 7 0 -9.3 0 -9 -9.4 03/26/2005 16:40:00 8.7 0.7 10.3 6.8 8.6 0.7 10.3 6.5 0.4 0 0.4 0.4 36 4 34 305 7 0 7 0 -9.3 0 -8.8 -9.6 03/26/2005 16:50:00 8.4 0.5 9.5 7.2 8.3 0.6 9.5 6.8 0.4 0 0.4 0.4 37 3 36 305 7 0 7 0 -9.3 0 -9 -9.4 03/26/2005 17:00:00 8.2 0.8 9.9 6.5 8.1 0.8 9.9 6.5 0.4 0 0.4 0.4 30 7 27 305 7 0 7 0 -9.2 0 -9 -9.4 03/26/2005 17:10:00 9.9 0.7 11.5 7.6 9.7 0.7 11.5 7.6 0.4 0 0.4 0.4 35 4 36 305 7 0 7 0 -9.5 0 -9.2 -9.6 03/26/2005 17:20:00 8.9 0.7 10.3 6.8 8.8 0.8 10.7 6.5 0.4 0 0.4 0.4 38 4 32 305 7 0 7 0 -9.4 0 -9.2 -9.6 03/26/2005 17:30:00 8.5 0.8 10.3 6.5 8.4 0.9 10.3 6.5 0.4 0 0.4 0.4 36 5 33 305 7 0 7 0 -9.3 0 -9 -9.4 03/26/2005 17:40:00 9 0.7 10.7 7.2 8.9 0.7 10.7 7.2 0.4 0 0.4 0.4 38 4 40 305 7 0 7 0 -9.4 0 -9.2 -9.6 03/26/2005 17:50:00 8.8 0.6 9.9 7.2 8.8 0.7 10.3 6.8 0.4 0 0.4 0.4 38 4 37 305 6 0 6 0 -9.4 0 -9.2 -9.6 03/26/2005 18:00:00 8.2 0.7 9.9 6.5 8.1 0.7 9.9 6.1 0.4 0 0.4 0.4 34 4 35 305 6 0 6 0 -9.3 0 -9 -9.6 03/26/2005 18:10:00 7.8 0.7 9.5 6.1 7.7 0.8 9.9 6.1 0.4 0 0.4 0.4 32 4 35 305 6 0 6 0 -9.4 0 -9.2 -9.6 03/26/2005 18:20:00 8.1 0.6 9.1 6.5 8 0.6 9.1 6.1 0.4 0 0.4 0.4 24 4 16 305 6 0 6 0 -9.4 0 -9 -9.4 03/26/2005 18:30:00 7.8 0.8 9.9 6.1 7.7 0.8 9.5 6.1 0.4 0 0.4 0.4 23 5 17 305 6 0 6 0 -9.3 0 -9 -9.4 03/26/2005 18:40:00 8.8 0.6 9.9 7.2 8.6 0.6 9.9 6.5 0.4 0 0.4 0.4 19 3 18 305 6 0 6 0 -9.4 0 -9 -9.6 03/26/2005 18:50:00 9 0.7 10.3 6.8 8.9 0.8 10.7 6.5 0.4 0 0.4 0.4 18 3 17 305 7 0 7 0 -9.3 0 -9 -9.4 03/26/2005 19:00:00 9.4 1 11.5 6.8 9.3 0.9 11.5 6.8 0.4 0 0.4 0.4 15 4 18 305 7 0 7 0 -9.2 0 -8.8 -9.2 03/26/2005 19:10:00 8.6 0.8 10.7 6.1 8.6 0.8 11.1 6.1 0.4 0 0.4 0.4 18 4 12 305 7 0 7 0 -9.1 0 -8.8 -9.2 03/26/2005 19:20:00 8.9 0.8 11.1 6.8 8.9 0.8 11.5 6.8 0.4 0 0.4 0.4 16 4 18 305 7 0 8 0 -9.1 0 -8.8 -9.2 03/26/2005 19:30:00 9.8 0.7 11.1 7.6 9.8 0.8 11.5 7.6 0.4 0 0.4 0.4 13 3 15 305 8 0 8 0 -9 0 -8.8 -9.2 03/26/2005 19:40:00 9.5 0.8 11.5 7.2 9.4 0.9 11.8 7.2 0.4 0 0.4 0.4 13 4 12 305 8 0 8 0 -9 0 -8.8 -9.2 03/26/2005 19:50:00 9.9 1 12.2 7.2 9.8 1 12.6 7.6 0.4 0 0.4 0.4 21 6 15 305 8 0 8 0 -8.9 0 -8.6 -9 03/26/2005 20:00:00 11 1.3 13.3 8 10.9 1.3 13.3 7.6 0.4 0 0.4 0.4 20 5 29 305 9 0 9 0 -8.9 0 -8.6 -9.2 03/26/2005 20:10:00 11 1.5 14.1 8 10.9 1.5 13.7 8 0.4 0 0.4 0.4 18 4 16 305 9 0 9 0 -8.9 0 -8.6 -9.2 03/26/2005 20:20:00 11 0.9 13 8.4 10.8 1 13.3 8.4 0.4 0 0.4 0.4 18 4 19 305 9 0 9 0 -9.1 0.1 -8.8 -9.2 03/26/2005 20:30:00 10.1 1.1 12.6 7.6 10.1 1.1 13 7.6 0.4 0 0.4 0.4 15 6 22 305 9 0 9 0 -9.1 0.1 -8.8 -9.2 03/26/2005 20:40:00 10.7 1 13 8.4 10.7 1 13.3 8.4 0.4 0 0.4 0.4 14 6 23 305 9 0 9 0 -9.2 0.1 -8.8 -9.2 03/26/2005 20:50:00 10.1 0.8 12.6 8.4 10.1 0.9 12.6 7.6 0.4 0 0.4 0.4 9 5 9 305 10 0 9 0 -9.3 0 -9 -9.4 03/26/2005 21:00:00 10.1 1.2 12.6 7.6 10.1 1.1 13 7.6 0.4 0 0.4 0.4 7 4 0 305 10 0 10 0 -9.5 0 -9.2 -9.6 03/26/2005 21:10:00 10.8 1 12.6 8.4 10.7 1 13 7.6 0.4 0 0.4 0.4 6 4 8 305 10 0 10 0 -9.5 0 -9.2 -9.6 03/26/2005 21:20:00 10.8 0.9 13 8.4 10.8 0.9 12.2 8.4 0.4 0 0.4 0.4 5 4 7 305 10 0 10 0 -9.5 0 -9.2 -9.6 03/26/2005 21:30:00 10.5 1 12.6 8 10.5 1.1 12.6 7.6 0.4 0 0.4 0.4 8 4 4 305 10 0 10 0 -9.6 0 -9.2 -9.6 03/26/2005 21:40:00 10 1 12.6 7.6 9.9 1 12.6 8 0.4 0 0.4 0.4 11 5 14 305 10 0 10 0 -9.5 0 -9.2 -9.6 03/26/2005 21:50:00 10.9 1.3 13.7 7.6 10.9 1.3 14.1 8 0.4 0 0.4 0.4 13 5 12 305 10 0 10 0 -9.5 0 -9.2 -9.6 03/26/2005 22:00:00 10.9 1.2 13.3 8 10.7 1.3 13.7 8 0.4 0 0.4 0.4 11 4 12 305 10 0 11 0 -9.6 0 -9 -9.6 03/26/2005 22:10:00 11.1 1.2 13.7 7.2 11 1.2 14.5 8 0.4 0 0.4 0.4 13 5 17 305 10 0 11 0 -9.5 0 -9.2 -9.6 03/26/2005 22:20:00 12.1 1.1 14.9 9.1 11.9 1.1 14.5 9.1 0.4 0 0.4 0.4 14 4 10 305 10 0 10 0 -9.7 0.1 -9.2 -9.8 03/26/2005 22:30:00 12.2 1.1 14.9 9.9 12 1.1 15.3 9.1 0.4 0 0.4 0.4 15 5 14 305 10 0 10 0 -9.8 0 -9.6 -10 03/26/2005 22:40:00 12 1.1 15.3 8 11.8 1.2 14.9 8.4 0.4 0 0.4 0.4 14 6 9 305 10 0 10 0 -9.8 0 -9.6 -10 03/26/2005 22:50:00 12.1 1.5 15.3 8.4 12 1.5 14.9 8.8 0.4 0 0.4 0.4 10 5 10 305 10 0 10 0 -9.9 0 -9.6 -10 03/26/2005 23:00:00 12.3 1.1 14.9 8.8 12.2 1.2 15.3 8.4 0.4 0 0.4 0.4 13 5 10 305 10 0 10 0 -9.9 0 -9.6 -10 03/26/2005 23:10:00 13.4 1.8 17.9 9.9 13.2 1.9 17.2 9.1 0.4 0 0.4 0.4 14 5 9 305 10 0 10 0 -10 0 -9.8 -10.2 03/26/2005 23:20:00 13.4 1.1 15.6 10.3 13.2 1.1 16.4 9.9 0.4 0 0.4 0.4 14 5 12 305 10 0 10 0 -10 0 -9.6 -10 03/26/2005 23:30:00 13.2 1.2 15.6 9.5 13.2 1.2 16.1 9.9 0.4 0 0.4 0.4 13 5 11 305 10 0 9 0 -10 0 -9.8 -10.2 03/26/2005 23:40:00 12.9 1.2 15.6 9.9 12.8 1.3 15.6 9.1 0.4 0 0.4 0.4 15 5 19 305 10 0 10 0 -10.1 0 -9.8 -10.2 03/26/2005 23:50:00 13.7 1.4 17.9 9.9 13.5 1.5 17.2 9.9 0.4 0 0.4 0.4 15 5 14 305 10 0 9 0 -10.1 0.1 -9.8 -10.2 03/27/2005 00:00:00 14.2 1.2 17.6 11.1 14 1.3 17.6 10.3 0.4 0 0.4 0.4 17 5 15 305 10 0 10 0 -10.2 0.1 -9.6 -10.4 03/27/2005 00:10:00 13.5 1.3 16.4 9.5 13.3 1.3 16.4 9.5 0.4 0 0.4 0.4 17 5 16 305 9 0 9 0 -10.2 0 -9.8 -10.4 03/27/2005 00:20:00 13.5 1.2 16.4 10.3 13.4 1.3 16.4 10.3 0.4 0 0.4 0.4 18 5 21 305 10 0 9 0 -10.2 0.1 -10 -10.4 03/27/2005 00:30:00 13.4 1.8 17.6 8.8 13.2 1.7 17.6 8.8 0.4 0 0.4 0.4 16 5 14 305 10 0 10 0 -10.1 0.1 -9.8 -10.4 03/27/2005 00:40:00 14.7 1.3 17.9 10.7 14.4 1.4 18.3 9.9 0.4 0 0.4 0.4 16 4 17 305 10 0 10 0 -10.1 0 -9.8 -10.2 03/27/2005 00:50:00 13.9 1.4 16.8 9.9 13.7 1.3 16.8 9.9 0.4 0 0.4 0.4 15 5 14 305 10 0 10 0 -9.9 0 -9.6 -10 03/27/2005 01:00:00 11.5 1.4 14.9 8.4 11.5 1.4 14.9 8 0.4 0 0.4 0.4 3 6 353 305 10 0 10 0 -10.2 0.1 -9.8 -10.4 03/27/2005 01:10:00 12.3 1.3 15.6 9.1 12.4 1.3 15.6 8.8 0.4 0 0.4 0.4 6 4 7 305 10 0 10 0 -10.5 0.1 -10 -10.9 03/27/2005 01:20:00 11.6 1.1 15.6 8.4 11.5 1.3 15.3 8.4 0.4 0 0.4 0.4 6 5 1 305 9 0 9 0 -10.7 0.1 -10.4 -10.9 03/27/2005 01:30:00 10.8 1.5 14.9 7.6 10.7 1.5 15.3 7.6 0.4 0 0.4 0.4 4 5 9 305 10 0 10 0 -10.7 0.1 -10.4 -10.9 03/27/2005 01:40:00 11.7 1 15.3 8.8 11.7 1.1 14.9 8.8 0.4 0 0.4 0.4 7 5 9 305 10 0 10 0 -10.7 0 -10.4 -10.9 03/27/2005 01:50:00 11.6 1.3 14.5 8.4 11.6 1.3 14.9 8.8 0.4 0 0.4 0.4 4 5 10 305 10 0 10 0 -10.7 0 -10.4 -10.9 03/27/2005 02:00:00 12 1.2 14.5 8.8 11.9 1.3 14.9 8.4 0.4 0 0.4 0.4 5 5 2 305 10 0 10 0 -10.8 0 -10.4 -10.9 03/27/2005 02:10:00 12.2 1.4 15.3 8.8 12 1.5 15.6 8.4 0.4 0 0.4 0.4 11 6 12 305 10 0 10 0 -10.7 0 -10.4 -10.9 03/27/2005 02:20:00 13.7 1.3 17.6 10.3 13.4 1.4 17.6 9.9 0.4 0 0.4 0.4 13 5 12 305 10 0 10 0 -10.7 0.1 -10.4 -10.9 03/27/2005 02:30:00 13.4 1.5 16.8 8.8 13.3 1.5 16.4 9.1 0.4 0 0.4 0.4 11 5 11 305 10 0 10 0 -10.9 0 -10.7 -11.1 03/27/2005 02:40:00 13.4 1.6 16.8 9.9 13.3 1.7 17.6 9.5 0.4 0 0.4 0.4 13 5 5 305 10 0 10 0 -11 0 -10.9 -11.3 03/27/2005 02:50:00 13.2 1.4 17.2 9.9 13.1 1.4 16.4 10.3 0.4 0 0.4 0.4 11 5 19 305 10 0 10 0 -11.1 0.1 -10.7 -11.3 03/27/2005 03:00:00 13.7 1.5 17.6 10.7 13.5 1.5 16.8 9.9 0.4 0 0.4 0.4 10 5 12 305 10 0 10 0 -11.3 0.1 -11.1 -11.5 03/27/2005 03:10:00 13.5 1.6 16.8 9.9 13.3 1.6 16.8 9.5 0.4 0 0.4 0.4 13 5 12 305 10 0 10 0 -11.4 0 -11.1 -11.5 03/27/2005 03:20:00 14.8 1.3 17.9 11.5 14.5 1.3 17.6 11.1 0.4 0 0.4 0.4 13 5 11 305 10 0 10 0 -11.5 0 -11.3 -11.7 03/27/2005 03:30:00 15 1.5 18.3 10.7 14.8 1.5 17.9 11.1 0.4 0 0.4 0.4 16 5 18 305 9 0 9 0 -11.5 0 -11.3 -11.7 03/27/2005 03:40:00 13.4 1.5 17.2 9.9 13.4 1.6 17.6 9.9 0.4 0 0.4 0.4 14 5 18 305 9 0 9 0 -11.6 0 -11.3 -11.9 03/27/2005 03:50:00 13.6 1.7 18.7 9.9 13.4 1.7 18.3 9.1 0.4 0 0.4 0.4 13 5 13 305 9 0 9 0 -11.9 0.1 -11.7 -12.1 03/27/2005 04:00:00 14.5 1.5 17.6 10.7 14.3 1.6 17.6 10.7 0.4 0 0.4 0.4 11 5 13 305 9 0 9 0 -12.1 0 -11.9 -12.3 03/27/2005 04:10:00 15.2 1.5 18.7 11.5 14.9 1.6 18.7 11.1 0.4 0 0.4 0.4 12 5 9 305 9 0 9 0 -12.4 0.1 -12.1 -12.5 03/27/2005 04:20:00 13.1 1.3 16.4 9.5 13 1.3 16.4 8.8 0.4 0 0.4 0.4 10 6 7 305 9 0 9 0 -12.6 0 -12.3 -12.9 03/27/2005 04:30:00 14.7 1.7 18.7 10.3 14.5 1.8 17.9 9.1 0.4 0 0.4 0.4 14 5 16 305 9 0 9 0 -12.7 0 -12.5 -12.9 03/27/2005 04:40:00 12.7 1.5 16.4 8.8 12.7 1.6 16.4 9.1 0.4 0 0.4 0.4 12 6 25 305 8 0 8 0 -12.7 0 -12.5 -12.9 03/27/2005 04:50:00 13.7 1.2 17.6 11.1 13.5 1.2 16.8 10.7 0.4 0 0.4 0.4 15 6 18 305 8 0 8 0 -12.9 0 -12.7 -12.9 03/27/2005 05:00:00 14.9 1.4 18.3 10.7 14.7 1.4 17.9 10.3 0.4 0 0.4 0.4 17 5 23 305 8 0 8 0 -12.8 0 -12.5 -12.9 03/27/2005 05:10:00 14.8 1.4 18.7 11.1 14.7 1.5 18.3 11.5 0.4 0 0.4 0.4 15 5 16 305 8 0 8 0 -13 0 -12.9 -13.1 03/27/2005 05:20:00 13.3 1.7 16.8 9.5 13.3 1.6 17.2 9.5 0.4 0 0.4 0.4 14 6 13 305 8 0 8 0 -12.9 0 -12.7 -13.1 03/27/2005 05:30:00 13.9 1.8 18.3 9.5 13.7 1.8 17.9 8.8 0.4 0 0.4 0.4 12 6 14 305 8 0 8 0 -12.8 0 -12.5 -12.9 03/27/2005 05:40:00 13.3 1.7 17.9 8.4 13.1 1.7 17.6 8.4 0.4 0 0.4 0.4 17 6 12 305 8 0 8 0 -12.8 0 -12.5 -13.1 03/27/2005 05:50:00 14 1.6 17.9 10.3 13.9 1.6 18.3 9.9 0.4 0 0.4 0.4 13 5 18 305 8 0 8 0 -12.6 0 -12.5 -12.9 03/27/2005 06:00:00 15.1 1.3 17.6 11.1 15 1.3 18.3 10.7 0.4 0 0.4 0.4 10 4 13 305 8 0 8 0 -12.6 0 -12.5 -12.9 03/27/2005 06:10:00 14 1.4 17.6 10.7 13.9 1.4 17.6 10.3 0.4 0 0.4 0.4 8 5 7 305 8 0 8 0 -12.8 0.1 -12.5 -12.9 03/27/2005 06:20:00 14.7 1.5 17.6 10.3 14.5 1.5 18.7 10.3 0.4 0 0.4 0.4 8 5 4 305 8 0 8 0 -12.9 0 -12.7 -13.1 03/27/2005 06:30:00 14.2 1.3 17.6 11.1 14.2 1.3 17.2 11.1 0.4 0 0.4 0.4 11 6 12 305 8 0 8 0 -12.9 0 -12.7 -12.9 03/27/2005 06:40:00 15.1 1.3 17.6 11.1 15 1.4 18.3 11.5 0.4 0 0.4 0.4 11 5 2 305 8 0 8 0 -12.9 0 -12.7 -13.1 03/27/2005 06:50:00 13.8 1.2 16.8 10.7 13.7 1.3 17.6 10.3 0.4 0 0.4 0.4 16 5 4 305 8 0 8 0 -12.8 0 -12.5 -12.9 03/27/2005 07:00:00 14.7 1.9 19.9 10.3 14.6 1.8 20.2 10.7 0.4 0 0.4 0.4 15 5 14 305 8 0 8 0 -12.7 0 -12.5 -12.9 03/27/2005 07:10:00 14.7 1.7 18.7 10.7 14.5 1.7 19.5 11.1 0.4 0 0.4 0.4 16 6 12 305 8 0 8 0 -13 0.1 -12.7 -13.1 03/27/2005 07:20:00 14.4 1.2 17.6 11.5 14.3 1.2 17.2 11.5 0.4 0 0.4 0.4 11 5 5 305 8 0 8 0 -13.2 0.1 -12.9 -13.5 03/27/2005 07:30:00 13.9 1.6 17.2 9.5 13.8 1.5 17.2 9.9 0.4 0 0.4 0.4 13 5 17 305 8 0 8 0 -13.2 0 -12.9 -13.5 03/27/2005 07:40:00 14.6 1.2 17.6 11.8 14.5 1.2 17.2 11.8 0.4 0 0.4 0.4 12 5 12 305 8 0 8 0 -13.3 0.1 -13.1 -13.5 03/27/2005 07:50:00 14.7 1.5 17.9 10.3 14.5 1.5 18.3 10.7 0.4 0 0.4 0.4 11 5 9 305 8 0 8 0 -13.3 0 -13.1 -13.5 03/27/2005 08:00:00 13.9 1.6 17.6 10.3 13.8 1.7 17.2 9.9 0.4 0 0.4 0.4 9 5 11 305 8 0 8 0 -13.5 0.1 -13.3 -13.7 03/27/2005 08:10:00 13.9 1.4 17.9 10.3 13.9 1.4 17.6 9.1 0.4 0 0.4 0.4 9 5 13 305 8 0 8 0 -13.5 0.1 -13.3 -13.7 03/27/2005 08:20:00 13.3 1.3 16.4 10.3 13.3 1.3 16.4 9.9 0.4 0 0.4 0.4 4 5 5 305 8 0 8 0 -13.8 0 -13.3 -14.1 03/27/2005 08:30:00 14 1.5 17.6 10.7 13.9 1.5 17.2 10.3 0.4 0 0.4 0.4 2 5 2 305 8 0 8 0 -14 0.2 -13.7 -14.4 03/27/2005 08:40:00 15.4 1.2 17.9 11.5 15.4 1.2 17.9 11.8 0.4 0 0.4 0.4 2 4 2 305 8 0 8 0 -14.3 0 -14.3 -14.6 03/27/2005 08:50:00 14.1 1.2 17.9 10.3 14 1.1 16.4 11.1 0.4 0 0.4 0.4 6 5 2 305 8 0 8 0 -14.3 0 -14.3 -14.4 03/27/2005 09:00:00 14.2 1.3 17.2 10.7 14.2 1.2 17.6 10.7 0.4 0 0.4 0.4 5 4 5 305 8 0 8 0 -14.2 0 -14.1 -14.3 03/27/2005 09:10:00 14.8 1.7 19.1 11.5 14.7 1.7 19.1 10.7 0.4 0 0.4 0.4 8 5 10 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 03/27/2005 09:20:00 14.2 1.2 17.2 10.7 14.1 1.2 17.6 10.7 0.4 0 0.4 0.4 7 5 7 305 8 0 8 0 -14 0.1 -13.7 -14.3 03/27/2005 09:30:00 14.1 1.1 17.2 10.3 14 1.2 16.4 9.9 0.4 0 0.4 0.4 8 6 6 305 8 0 8 0 -14 0.1 -13.7 -14.3 03/27/2005 09:40:00 15.4 1.9 19.1 10.7 15.3 1.9 19.5 10.7 0.4 0 0.4 0.4 9 6 16 305 8 0 8 0 -13.8 0 -13.7 -14.1 03/27/2005 09:50:00 13.5 1.3 16.8 10.7 13.4 1.4 16.8 10.3 0.4 0 0.4 0.4 5 6 3 305 8 0 8 0 -14.2 0.1 -13.7 -14.4 03/27/2005 10:00:00 14.6 1.6 18.3 10.7 14.5 1.6 18.3 11.1 0.4 0 0.4 0.4 359 6 12 305 8 0 8 0 -14.6 0.2 -14.1 -14.8 03/27/2005 10:10:00 15.6 1.5 19.1 11.5 15.4 1.6 18.7 11.1 0.4 0 0.4 0.4 4 5 5 305 8 0 8 0 -14.8 0 -14.6 -14.8 03/27/2005 10:20:00 14.8 1.6 17.9 11.5 14.8 1.5 18.3 11.1 0.4 0 0.4 0.4 5 5 4 305 8 0 8 0 -14.7 0 -14.4 -14.8 03/27/2005 10:30:00 14.2 1.6 17.9 10.7 14.1 1.6 17.6 10.3 0.4 0 0.4 0.4 4 5 4 305 8 0 8 0 -14.7 0 -14.4 -14.8 03/27/2005 10:40:00 15.1 1 17.2 11.8 15.1 1 17.6 12.6 0.4 0 0.4 0.4 7 5 2 305 8 0 8 0 -14.7 0 -14.4 -14.8 03/27/2005 10:50:00 15.3 1.5 18.3 10.7 15.1 1.6 18.3 11.1 0.4 0 0.4 0.4 9 5 9 305 8 0 8 0 -14.6 0 -14.3 -14.6 03/27/2005 11:00:00 15.4 1.4 18.3 11.8 15.3 1.4 18.3 11.8 0.4 0 0.4 0.4 7 4 3 305 8 0 8 0 -14.7 0 -14.4 -14.8 03/27/2005 11:10:00 15.2 1.2 17.9 12.2 15.2 1.1 17.6 11.8 0.4 0 0.4 0.4 8 4 359 305 8 0 8 0 -14.6 0 -14.4 -14.8 03/27/2005 11:20:00 14.2 1.5 18.3 10.3 14 1.5 18.3 10.7 0.4 0 0.4 0.4 14 6 21 305 8 0 8 0 -14.4 0.1 -14.1 -14.6 03/27/2005 11:30:00 15.4 1.5 19.1 10.7 15.2 1.5 19.1 11.8 0.4 0 0.4 0.4 15 5 13 305 8 0 8 0 -14.2 0 -14.1 -14.3 03/27/2005 11:40:00 15.1 1.7 18.3 10.3 14.9 1.7 18.3 11.1 0.4 0 0.4 0.4 17 5 11 305 8 0 8 0 -14.2 0 -13.9 -14.3 03/27/2005 11:50:00 15.5 1.7 19.1 10.7 15.3 1.7 19.1 10.7 0.4 0 0.4 0.4 16 6 22 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 03/27/2005 12:00:00 15.9 1.5 19.5 11.8 15.6 1.5 19.5 11.5 0.4 0 0.4 0.4 13 5 9 305 8 0 8 0 -14.1 0 -13.7 -14.3 03/27/2005 12:10:00 15.5 1.3 18.7 11.8 15.3 1.4 18.3 11.8 0.4 0 0.4 0.4 13 5 15 305 8 0 8 0 -14.1 0 -13.7 -14.3 03/27/2005 12:20:00 15.6 1.6 19.1 12.2 15.4 1.6 18.7 11.5 0.4 0 0.4 0.4 13 5 6 305 8 0 8 0 -14.1 0 -13.7 -14.3 03/27/2005 12:30:00 15.4 1.5 18.7 11.1 15.2 1.5 19.5 11.1 0.4 0 0.4 0.4 12 5 14 305 8 0 8 0 -14.1 0.1 -13.7 -14.3 03/27/2005 12:40:00 15.3 1.4 19.1 11.1 15.1 1.5 19.5 10.7 0.4 0 0.4 0.4 13 5 10 305 8 0 8 0 -13.9 0.1 -13.7 -14.3 03/27/2005 12:50:00 15.9 1.3 19.1 12.2 15.8 1.4 19.1 12.2 0.4 0 0.4 0.4 13 5 8 305 8 0 8 0 -13.8 0.1 -13.3 -14.1 03/27/2005 13:00:00 15.8 1.5 19.9 11.5 15.6 1.5 20.2 11.8 0.4 0 0.4 0.4 11 5 3 305 8 0 8 0 -13.7 0 -13.5 -13.9 03/27/2005 13:10:00 15.8 1.8 19.9 11.1 15.7 1.8 19.9 11.5 0.4 0 0.4 0.4 11 5 5 305 8 0 8 0 -13.7 0 -13.3 -13.9 03/27/2005 13:20:00 16.3 1.3 19.1 12.2 16.3 1.3 19.1 12.2 0.4 0 0.4 0.4 9 4 8 305 8 0 8 0 -13.7 0.1 -13.3 -13.9 03/27/2005 13:30:00 15.9 1.5 19.5 12.2 15.9 1.5 19.5 11.8 0.4 0 0.4 0.4 8 5 11 305 8 0 8 0 -13.6 0 -13.3 -13.9 03/27/2005 13:40:00 16 1.5 19.9 11.8 15.9 1.5 19.9 11.5 0.4 0 0.4 0.4 5 5 6 305 7 0 7 0 -13.8 0 -13.5 -14.3 03/27/2005 13:50:00 15 1.7 18.3 10.7 14.8 1.7 18.7 11.1 0.4 0 0.4 0.4 8 6 4 305 8 0 7 0 -13.6 0.1 -13.1 -13.9 03/27/2005 14:00:00 15.5 1.5 18.3 11.1 15.3 1.6 18.7 11.5 0.4 0 0.4 0.4 4 5 3 305 7 0 7 0 -14.1 0.1 -13.7 -14.3 03/27/2005 14:10:00 15.7 1.2 18.3 12.2 15.6 1.2 17.9 12.2 0.4 0 0.4 0.4 5 5 358 305 7 0 7 0 -14.2 0 -14.1 -14.4 03/27/2005 14:20:00 14.9 1.6 18.3 11.1 14.9 1.6 18.3 11.1 0.4 0 0.4 0.4 5 6 359 305 7 0 7 0 -14.2 0.1 -13.7 -14.4 03/27/2005 14:30:00 15.6 1.6 19.5 11.1 15.5 1.7 19.1 11.1 0.4 0 0.4 0.4 4 5 359 305 7 0 7 0 -14.3 0 -14.3 -14.6 03/27/2005 14:40:00 15.7 1.4 19.1 11.1 15.5 1.3 19.5 11.1 0.4 0 0.4 0.4 6 5 8 305 7 0 7 0 -14.4 0 -14.3 -14.6 03/27/2005 14:50:00 15.3 1.4 18.3 11.5 15.2 1.4 18.7 11.1 0.4 0 0.4 0.4 7 6 4 305 7 0 7 0 -14.4 0.1 -14.1 -14.6 03/27/2005 15:00:00 15.1 1.2 18.3 11.5 15 1.2 17.9 11.8 0.4 0 0.4 0.4 6 5 7 305 7 0 7 0 -14.2 0 -14.1 -14.4 03/27/2005 15:10:00 14.8 1.5 17.9 10.3 14.7 1.5 17.9 10.7 0.4 0 0.4 0.4 7 5 9 305 7 0 7 0 -14.2 0.1 -13.7 -14.4 03/27/2005 15:20:00 15.6 1.4 19.5 12.2 15.6 1.4 19.1 12.6 0.4 0 0.4 0.4 7 5 7 305 7 0 7 0 -14.2 0 -13.9 -14.4 03/27/2005 15:30:00 15.5 1.2 18.7 12.2 15.5 1.3 18.7 11.8 0.4 0 0.4 0.4 9 5 2 305 7 0 7 0 -14.2 0 -13.9 -14.4 03/27/2005 15:40:00 15.6 1.4 18.7 11.5 15.6 1.5 19.1 11.5 0.4 0 0.4 0.4 6 4 358 305 7 0 7 0 -14.4 0.1 -13.9 -14.6 03/27/2005 15:50:00 15.4 1.5 19.5 11.8 15.3 1.6 19.5 11.8 0.4 0 0.4 0.4 8 5 4 305 7 0 6 0 -14.4 0.1 -14.3 -14.6 03/27/2005 16:00:00 14.4 1.5 18.3 10.7 14.3 1.5 17.9 10.7 0.4 0 0.4 0.4 5 6 1 305 6 0 6 0 -14.4 0 -14.3 -14.6 03/27/2005 16:10:00 14.7 1.5 18.7 10.7 14.6 1.5 18.7 11.1 0.4 0 0.4 0.4 5 6 5 305 7 0 7 0 -14.4 0.1 -14.1 -14.6 03/27/2005 16:20:00 14.7 1.8 18.7 10.3 14.7 1.7 18.7 9.9 0.4 0 0.4 0.4 7 5 7 305 7 0 7 0 -14.4 0 -14.1 -14.6 03/27/2005 16:30:00 14.8 1.6 19.1 11.5 14.8 1.7 19.1 10.7 0.4 0 0.4 0.4 6 5 14 305 7 0 6 0 -14.4 0 -14.1 -14.6 03/27/2005 16:40:00 15.4 1.5 18.7 11.5 15.3 1.5 19.1 11.8 0.4 0 0.4 0.4 5 5 10 305 7 0 7 0 -14.4 0 -14.3 -14.6 03/27/2005 16:50:00 15.9 1.2 18.7 12.6 15.7 1.2 18.7 12.2 0.4 0 0.4 0.4 5 5 0 305 6 0 6 0 -14.5 0 -14.3 -14.6 03/27/2005 17:00:00 16.8 1.3 19.5 13 16.7 1.4 19.5 12.2 0.4 0 0.4 0.4 7 4 10 305 6 0 6 0 -14.4 0 -14.1 -14.6 03/27/2005 17:10:00 15.9 1.7 19.9 10.7 15.8 1.7 19.9 10.7 0.4 0 0.4 0.4 7 5 7 305 6 0 6 0 -14.3 0 -13.9 -14.4 03/27/2005 17:20:00 15.4 1.6 19.1 10.7 15.5 1.6 18.3 10.3 0.4 0 0.4 0.4 4 5 5 305 6 0 6 0 -14.4 0 -14.1 -14.6 03/27/2005 17:30:00 15.5 1.9 19.1 11.1 15.4 1.9 19.5 10.7 0.4 0 0.4 0.4 3 5 1 305 6 0 6 0 -14.6 0.1 -14.3 -14.8 03/27/2005 17:40:00 15.7 1.4 19.1 12.2 15.6 1.5 19.1 12.2 0.4 0 0.4 0.4 2 5 3 305 6 0 6 0 -14.8 0 -14.4 -15 03/27/2005 17:50:00 15.6 1.5 18.7 11.1 15.6 1.5 19.9 10.7 0.4 0 0.4 0.4 3 5 1 305 6 0 6 0 -14.8 0 -14.4 -15 03/27/2005 18:00:00 14.1 1.5 17.6 10.3 14.1 1.5 17.9 9.9 0.4 0 0.4 0.4 4 5 9 305 5 0 6 0 -14.6 0.1 -14.3 -15 03/27/2005 18:10:00 15.3 1.4 18.3 11.1 15.3 1.4 18.7 11.5 0.4 0 0.4 0.4 5 5 6 305 6 0 6 0 -14.7 0 -14.4 -15 03/27/2005 18:20:00 15.3 1.5 19.1 10.3 15.1 1.5 18.7 11.5 0.4 0 0.4 0.4 5 5 10 305 5 0 5 0 -15 0.1 -14.6 -15.2 03/27/2005 18:30:00 16 1.6 18.7 11.5 15.9 1.6 19.1 12.2 0.4 0 0.4 0.4 3 4 0 305 5 0 5 0 -15.1 0 -14.8 -15.2 03/27/2005 18:40:00 16 1.2 18.7 12.2 15.9 1.3 19.1 13 0.4 0 0.4 0.4 3 4 5 305 5 0 5 0 -15.3 0 -15 -15.6 03/27/2005 18:50:00 16 1.5 19.1 12.2 15.8 1.5 18.7 11.5 0.4 0 0.4 0.4 4 4 5 305 5 0 5 0 -15.6 0.1 -15.2 -15.8 03/27/2005 19:00:00 16 1.2 18.3 12.6 15.8 1.3 18.3 11.8 0.4 0 0.4 0.4 6 4 358 305 5 0 5 0 -15.7 0 -15.4 -15.8 03/27/2005 19:10:00 15.1 1.6 18.7 10.7 14.9 1.6 18.3 11.1 0.4 0 0.4 0.4 6 6 8 305 5 0 5 0 -15.5 0 -15.2 -15.6 03/27/2005 19:20:00 15.1 1.2 17.9 11.5 15 1.3 17.9 11.5 0.4 0 0.4 0.4 7 5 0 305 5 0 5 0 -15.4 0.1 -15 -15.6 03/27/2005 19:30:00 15.2 1.2 17.9 12.2 15 1.2 18.3 11.1 0.4 0 0.4 0.4 7 4 8 305 5 0 5 0 -15.6 0 -15.2 -15.8 03/27/2005 19:40:00 16.1 1.5 19.9 11.5 16 1.6 19.9 11.8 0.4 0 0.4 0.4 7 5 4 305 5 0 5 0 -15.6 0.1 -15.4 -15.8 03/27/2005 19:50:00 16.1 1.3 19.1 11.8 15.9 1.4 19.5 12.6 0.4 0 0.4 0.4 6 5 1 305 5 0 5 0 -15.8 0 -15.6 -16 03/27/2005 20:00:00 16.5 1.5 19.1 12.2 16.3 1.5 19.9 11.1 0.4 0 0.4 0.4 4 4 0 305 5 0 5 0 -16 0.1 -15.8 -16.4 03/27/2005 20:10:00 16.3 1.5 19.1 11.8 16.2 1.5 19.9 12.2 0.4 0 0.4 0.4 3 5 6 305 5 0 5 0 -16.2 0.1 -16 -16.4 03/27/2005 20:20:00 16.1 1.6 19.5 12.2 15.9 1.6 19.1 11.8 0.4 0 0.4 0.4 4 5 4 305 5 0 5 0 -16.3 0 -16.2 -16.4 03/27/2005 20:30:00 16 1.6 19.9 10.7 15.7 1.6 19.1 11.1 0.4 0 0.4 0.4 5 5 10 305 5 0 5 0 -16.3 0 -16 -16.4 03/27/2005 20:40:00 15.2 1.5 18.7 11.5 15.1 1.5 19.5 11.1 0.4 0 0.4 0.4 6 6 3 305 5 0 5 0 -16.2 0.1 -16 -16.6 03/27/2005 20:50:00 15.3 1.5 18.3 9.9 15.2 1.5 18.3 11.1 0.4 0 0.4 0.4 8 5 9 305 5 0 5 0 -16.2 0 -16 -16.4 03/27/2005 21:00:00 15.9 1.5 19.5 11.8 15.7 1.6 19.5 10.3 0.4 0 0.4 0.4 8 5 9 305 5 0 5 0 -16.3 0 -16 -16.6 03/27/2005 21:10:00 16.5 1.4 19.5 12.2 16.3 1.5 19.1 12.2 0.4 0 0.4 0.4 7 5 10 305 5 0 5 0 -16.7 0.1 -16.4 -16.9 03/27/2005 21:20:00 15.1 1.6 19.1 10.3 14.9 1.6 19.5 11.1 0.4 0 0.4 0.4 7 5 6 305 5 0 5 0 -16.7 0.1 -16.4 -16.9 03/27/2005 21:30:00 16.1 1.6 19.9 12.2 16 1.5 19.5 12.2 0.4 0 0.4 0.4 7 5 10 305 5 0 5 0 -16.9 0 -16.6 -16.9 03/27/2005 21:40:00 15.8 1.2 19.5 12.6 15.6 1.3 19.1 12.6 0.4 0 0.4 0.4 8 5 10 305 5 0 6 0 -16.9 0 -16.9 -16.9 03/27/2005 21:50:00 16 1.4 19.5 11.8 15.9 1.4 19.1 12.6 0.4 0 0.4 0.4 8 4 4 305 5 0 6 0 -17 0.1 -16.9 -17.3 03/27/2005 22:00:00 15.9 1.4 18.7 12.2 15.8 1.5 18.7 11.5 0.4 0 0.4 0.4 7 5 10 305 5 0 5 0 -17.3 0 -17.1 -17.5 03/27/2005 22:10:00 15.7 1.3 18.7 11.1 15.5 1.5 18.7 10.7 0.4 0 0.4 0.4 6 5 8 305 5 0 5 0 -17.4 0 -17.1 -17.5 03/27/2005 22:20:00 14.8 1.5 17.9 11.1 14.7 1.3 18.3 11.1 0.4 0 0.4 0.4 6 4 5 305 5 0 5 0 -17.4 0.1 -17.1 -17.5 03/27/2005 22:30:00 14.7 1.3 18.3 10.7 14.7 1.4 18.3 10.7 0.4 0 0.4 0.4 6 5 13 305 5 0 5 0 -17.4 0 -17.1 -17.5 03/27/2005 22:40:00 14.4 1.3 17.6 10.7 14.3 1.4 16.8 10.3 0.4 0 0.4 0.4 5 5 0 305 5 0 5 0 -17.5 0 -17.3 -17.7 03/27/2005 22:50:00 15.3 1.5 18.3 11.1 15.1 1.5 18.3 11.1 0.4 0 0.4 0.4 5 5 1 305 5 0 5 0 -17.7 0.1 -17.5 -18.1 03/27/2005 23:00:00 14.3 1.6 17.6 10.3 14.3 1.6 17.6 10.7 0.4 0 0.4 0.4 4 5 2 305 5 0 5 0 -17.8 0 -17.5 -18.1 03/27/2005 23:10:00 14.6 1.3 17.6 11.1 14.6 1.3 17.6 11.5 0.4 0 0.4 0.4 3 5 3 305 5 0 5 0 -18 0 -17.9 -18.2 03/27/2005 23:20:00 14.9 1.3 17.6 11.1 14.9 1.3 18.3 11.5 0.4 0 0.4 0.4 5 4 5 305 5 0 5 0 -18.3 0.1 -18.1 -18.4 03/27/2005 23:30:00 14.7 1.5 17.2 10.7 14.6 1.4 17.2 11.1 0.4 0 0.4 0.4 2 5 6 305 5 0 5 0 -18.5 0 -18.2 -18.4 03/27/2005 23:40:00 14.1 1.4 17.2 10.3 14.1 1.5 17.6 10.3 0.4 0 0.4 0.4 2 5 1 305 5 0 5 0 -18.5 0 -18.2 -18.4 03/27/2005 23:50:00 14.6 1.4 17.2 10.7 14.5 1.4 17.2 10.7 0.4 0 0.4 0.4 2 4 1 305 5 0 5 0 -18.5 0 -18.4 -18.6 03/28/2005 00:00:00 14.7 1.1 17.2 11.8 14.6 1.1 17.6 11.1 0.4 0 0.4 0.4 3 4 1 305 5 0 5 0 -18.6 0 -18.2 -18.8 03/28/2005 00:10:00 13.5 1.3 16.8 10.3 13.4 1.3 16.8 10.3 0.4 0 0.4 0.4 3 5 3 305 5 0 5 0 -18.6 0 -18.1 -18.6 03/28/2005 00:20:00 14.1 1.5 17.2 9.9 14.1 1.7 17.6 9.5 0.4 0 0.4 0.4 6 5 5 305 5 0 5 0 -18.6 0 -18.4 -18.6 03/28/2005 00:30:00 14 1.7 16.8 9.1 13.9 1.7 17.2 9.1 0.4 0 0.4 0.4 4 5 1 305 5 0 5 0 -18.6 0.1 -18.2 -18.8 03/28/2005 00:40:00 14.5 1.2 16.8 11.1 14.4 1.2 16.8 10.3 0.4 0 0.4 0.4 6 4 8 305 5 0 5 0 -18.6 0 -18.4 -18.8 03/28/2005 00:50:00 14.8 1.3 17.2 10.3 14.7 1.4 17.2 10.7 0.4 0 0.4 0.4 6 4 10 305 5 0 5 0 -18.6 0 -18.4 -18.8 03/28/2005 01:00:00 14.1 1.4 16.8 10.3 14 1.4 16.8 10.3 0.4 0 0.4 0.4 2 5 5 305 5 0 5 0 -18.7 0 -18.4 -19 03/28/2005 01:10:00 13.9 1.5 17.2 9.9 13.9 1.5 17.6 9.9 0.4 0 0.4 0.4 1 5 0 305 5 0 5 0 -18.9 0.1 -18.4 -19 03/28/2005 01:20:00 12.8 1.3 16.4 9.5 12.8 1.4 15.6 9.9 0.4 0 0.4 0.4 6 5 0 305 5 0 5 0 -18.9 0 -18.6 -19 03/28/2005 01:30:00 13.6 1.3 16.8 9.9 13.5 1.4 16.4 10.3 0.4 0 0.4 0.4 6 5 11 305 5 0 5 0 -19.1 0 -19 -19.2 03/28/2005 01:40:00 12.7 1.1 14.9 8.8 12.7 1.1 15.6 9.5 0.4 0 0.4 0.4 11 5 13 305 5 0 5 0 -19.1 0 -18.4 -19.2 03/28/2005 01:50:00 13.2 1.5 16.4 8.8 13 1.4 16.8 9.1 0.4 0 0.4 0.4 8 5 5 305 5 0 5 0 -19.1 0 -19 -19.2 03/28/2005 02:00:00 13.6 1.1 16.1 9.9 13.6 1.1 16.1 10.7 0.4 0 0.4 0.4 7 4 8 305 5 0 5 0 -19.1 0 -18.4 -19.2 03/28/2005 02:10:00 13.2 1.1 15.3 10.3 13.1 1.2 16.1 9.5 0.4 0 0.4 0.4 8 5 8 305 5 0 5 0 -19 0 -18.8 -19 03/28/2005 02:20:00 13 1.3 16.4 9.9 12.9 1.3 16.1 8.8 0.4 0 0.4 0.4 11 5 5 305 5 0 5 0 -19.1 0 -18.8 -19.2 03/28/2005 02:30:00 13.6 1.1 16.8 10.3 13.5 1.2 16.1 10.7 0.4 0 0.4 0.4 8 5 0 305 5 0 5 0 -19.2 0 -19 -19.3 03/28/2005 02:40:00 12.8 1.3 15.3 9.1 12.8 1.3 15.3 9.1 0.4 0 0.4 0.4 7 5 3 305 5 0 5 0 -19.2 0.1 -19 -19.5 03/28/2005 02:50:00 12.3 1.3 15.3 9.1 12.3 1.3 15.3 8.4 0.4 0 0.4 0.4 4 5 12 305 4 0 5 0 -19.4 0 -19.2 -19.5 03/28/2005 03:00:00 13.8 1.2 16.1 9.9 13.8 1.2 16.1 10.3 0.4 0 0.4 0.4 5 5 11 305 4 0 5 0 -19.4 0.1 -19.2 -19.5 03/28/2005 03:10:00 13.7 1.2 16.4 9.9 13.6 1.2 16.4 10.3 0.4 0 0.4 0.4 2 4 4 305 4 0 4 0 -19.6 0 -19.3 -19.9 03/28/2005 03:20:00 13.4 1 15.6 9.9 13.3 1.1 15.6 10.7 0.4 0 0.4 0.4 9 4 3 305 4 0 4 0 -19.7 0 -19.5 -19.9 03/28/2005 03:30:00 14.3 1 16.1 10.7 14.4 1.1 16.4 10.3 0.4 0 0.4 0.4 8 3 7 305 4 0 4 0 -19.7 0 -19.5 -19.7 03/28/2005 03:40:00 13.1 0.9 15.3 10.7 13.2 1 15.3 9.9 0.4 0 0.4 0.4 9 4 10 305 4 0 5 0 -19.7 0 -19.5 -19.9 03/28/2005 03:50:00 12.8 1.2 15.6 8.8 12.7 1.3 15.3 9.5 0.4 0 0.4 0.4 8 5 10 305 4 0 4 0 -19.7 0 -19.5 -19.9 03/28/2005 04:00:00 13.3 1.1 16.1 10.3 13.3 1.2 16.4 10.7 0.4 0 0.4 0.4 8 5 7 305 4 0 4 0 -19.7 0 -19.5 -19.9 03/28/2005 04:10:00 13 1.5 15.6 9.9 13 1.5 16.1 9.5 0.4 0 0.4 0.4 9 4 7 305 4 0 4 0 -19.9 0.1 -19.5 -20.1 03/28/2005 04:20:00 13.8 1 16.1 11.1 13.7 1.1 16.1 10.7 0.4 0 0.4 0.4 8 4 9 305 4 0 4 0 -20 0.1 -19.5 -20.1 03/28/2005 04:30:00 13.4 1.1 15.6 10.3 13.3 1.2 15.6 9.5 0.4 0 0.4 0.4 7 5 13 305 4 0 4 0 -20.2 0 -19.9 -20.2 03/28/2005 04:40:00 13 1.2 15.6 8.4 13 1.2 15.6 9.5 0.4 0 0.4 0.4 10 4 5 305 4 0 4 0 -20.3 0 -20.1 -20.4 03/28/2005 04:50:00 13 1.1 15.3 10.3 13 1.1 15.6 9.9 0.4 0 0.4 0.4 7 4 11 305 4 0 4 0 -20.3 0.1 -19.5 -20.6 03/28/2005 05:00:00 11.9 1 14.1 9.1 11.8 1.1 14.5 8.8 0.4 0 0.4 0.4 8 5 0 305 4 0 4 0 -20.4 0 -20.1 -20.6 03/28/2005 05:10:00 13.1 1.2 15.3 9.1 13 1.3 15.6 9.5 0.4 0 0.4 0.4 6 4 7 305 4 0 4 0 -20.6 0.1 -20.2 -20.8 03/28/2005 05:20:00 13.4 1.1 15.6 9.9 13.3 1.2 16.1 10.3 0.4 0 0.4 0.4 7 4 7 305 4 0 4 0 -20.7 0 -20.6 -20.8 03/28/2005 05:30:00 11.8 1.1 14.1 8.8 11.9 1.2 14.5 8.8 0.4 0 0.4 0.4 4 5 2 305 4 0 4 0 -20.6 0 -20.4 -20.8 03/28/2005 05:40:00 13.1 1.1 15.6 9.9 13 1.2 15.6 9.9 0.4 0 0.4 0.4 5 5 10 305 4 0 4 0 -20.8 0.1 -20.4 -21.1 03/28/2005 05:50:00 13 1.2 15.6 9.1 12.9 1.3 15.6 9.5 0.4 0 0.4 0.4 2 5 359 305 4 0 4 0 -21 0.1 -20.4 -21.3 03/28/2005 06:00:00 12.7 1.2 14.9 9.1 12.6 1.2 15.3 9.5 0.4 0 0.4 0.4 6 3 8 305 4 0 4 0 -21 0.1 -20.4 -21.3 03/28/2005 06:10:00 12.6 1.1 14.9 9.5 12.7 1.1 15.6 9.1 0.4 0 0.4 0.4 3 5 357 305 4 0 4 0 -20.9 0.1 -20.4 -21.1 03/28/2005 06:20:00 12.4 1 14.5 9.5 12.4 1 14.5 9.5 0.4 0 0.4 0.4 5 4 5 305 4 0 4 0 -21 0.1 -20.4 -21.1 03/28/2005 06:30:00 12.2 1 14.1 9.5 12.2 1.1 14.5 8.8 0.4 0 0.4 0.4 4 4 0 305 4 0 4 0 -21 0.1 -20.4 -21.3 03/28/2005 06:40:00 11.9 1.1 14.5 8.8 12 1.1 14.9 8.8 0.4 0 0.4 0.4 3 4 6 305 4 0 4 0 -21 0.1 -20.4 -21.1 03/28/2005 06:50:00 11.8 1.1 14.1 8.8 11.8 1.2 14.5 9.1 0.4 0 0.4 0.4 3 5 1 305 4 0 4 0 -21.1 0.1 -20.4 -21.3 03/28/2005 07:00:00 11.7 1.3 14.1 8 11.6 1.3 14.1 7.6 0.4 0 0.4 0.4 5 5 8 305 4 0 4 0 -21.2 0 -20.8 -21.3 03/28/2005 07:10:00 11.7 1 13.7 8.4 11.8 1 13.7 9.1 0.4 0 0.4 0.4 3 4 7 305 4 0 4 0 -21.3 0.1 -20.8 -21.3 03/28/2005 07:20:00 11.8 1.1 14.1 8.8 11.7 1.1 14.1 8.8 0.4 0 0.4 0.4 6 4 8 305 4 0 4 0 -21.3 0.1 -20.8 -21.7 03/28/2005 07:30:00 11.6 0.8 13.3 9.5 11.4 0.9 13.3 9.1 0.4 0 0.4 0.4 3 4 2 305 4 0 4 0 -21.4 0.1 -21 -21.5 03/28/2005 07:40:00 11.1 1.1 13.7 7.6 11 1 13.3 8 0.4 0 0.4 0.4 3 4 5 305 4 0 4 0 -21.3 0.1 -20.8 -21.5 03/28/2005 07:50:00 11.2 1 13.3 8.8 11.2 1 13.3 8.4 0.4 0 0.4 0.4 3 4 5 305 4 0 4 0 -21.1 0.1 -20.8 -21.3 03/28/2005 08:00:00 11.7 0.8 13.3 9.1 11.7 1 13.7 8.4 0.4 0 0.4 0.4 5 5 7 305 4 0 4 0 -21.1 0.1 -20.8 -21.3 03/28/2005 08:10:00 11.1 1.2 13.3 7.6 11.1 1.3 13.3 8 0.4 0 0.4 0.4 5 4 0 305 4 0 4 0 -21 0 -20.4 -21.3 03/28/2005 08:20:00 10.8 1.2 13.7 8 10.8 1.2 13.3 7.6 0.4 0 0.4 0.4 1 6 5 305 4 0 4 0 -21 0 -20.4 -21.3 03/28/2005 08:30:00 11.8 1.2 14.1 8.4 11.5 1.2 14.5 7.6 0.4 0 0.4 0.4 6 5 4 305 4 0 4 0 -21.1 0.1 -20.6 -21.3 03/28/2005 08:40:00 11.1 1.2 14.1 7.6 11.2 1.2 14.5 7.2 0.4 0 0.4 0.4 3 5 4 305 4 0 4 0 -21.1 0.1 -20.6 -21.3 03/28/2005 08:50:00 11.1 1.3 13.7 8 11.1 1.3 13.7 7.6 0.4 0 0.4 0.4 4 4 3 305 4 0 4 0 -21.1 0.1 -20.4 -21.3 03/28/2005 09:00:00 11.3 1.1 13.7 8.4 11.4 1.1 13.7 8.8 0.4 0 0.4 0.4 3 5 4 305 4 0 4 0 -21.3 0 -21.1 -21.3 03/28/2005 09:10:00 11.3 1 13.3 8 11.3 1.1 13.7 8 0.4 0 0.4 0.4 1 5 1 305 4 0 4 0 -21.2 0 -21 -21.3 03/28/2005 09:20:00 10.8 1.2 13.3 8 10.8 1.2 13.3 8 0.4 0 0.4 0.4 0 5 8 305 4 0 4 0 -21.1 0 -21 -21.3 03/28/2005 09:30:00 10.6 1.1 13 7.6 10.6 1.1 12.6 7.6 0.4 0 0.4 0.4 1 5 7 305 4 0 4 0 -21 0 -20.8 -21.3 03/28/2005 09:40:00 11.1 1.4 13.3 7.2 11.2 1.4 13.3 7.6 0.4 0 0.4 0.4 2 5 2 305 4 0 4 0 -21.1 0.1 -20.8 -21.3 03/28/2005 09:50:00 10.4 1.2 13 6.8 10.4 1.2 13 7.2 0.4 0 0.4 0.4 0 5 354 305 4 0 4 0 -21.1 0.1 -20.8 -21.3 03/28/2005 10:00:00 11.1 1.2 13.7 7.2 11.1 1.3 14.1 7.6 0.4 0 0.4 0.4 3 5 359 305 4 0 4 0 -21.2 0 -21 -21.3 03/28/2005 10:10:00 11.6 0.7 13.3 9.5 11.5 0.8 13.3 8.8 0.4 0 0.4 0.4 6 4 10 305 4 0 4 0 -21.2 0 -21 -21.3 03/28/2005 10:20:00 11.1 1 13.3 7.6 11.1 1 13.7 8 0.4 0 0.4 0.4 3 5 5 305 4 0 4 0 -21.1 0 -21 -21.3 03/28/2005 10:30:00 11.4 0.9 13.3 8.4 11.3 1 13.3 8.4 0.4 0 0.4 0.4 5 4 8 305 4 0 4 0 -21 0 -20.8 -21.3 03/28/2005 10:40:00 11.1 0.8 12.6 8.4 11 0.9 13 8.8 0.4 0 0.4 0.4 5 4 4 305 4 0 4 0 -20.9 0.1 -20.8 -21.1 03/28/2005 10:50:00 10.8 1.2 13.3 6.8 10.9 1 13.3 8 0.4 0 0.4 0.4 6 4 3 305 4 0 4 0 -20.8 0.1 -20.4 -21 03/28/2005 11:00:00 10.2 0.9 13 8 10.1 1 12.2 7.6 0.4 0 0.4 0.4 4 4 2 305 4 0 4 0 -20.6 0 -20.4 -20.8 03/28/2005 11:10:00 11.1 0.7 13 8.4 11.1 0.8 13 8.4 0.4 0 0.4 0.4 2 4 1 305 4 0 4 0 -20.7 0 -20.6 -20.8 03/28/2005 11:20:00 11 1.1 13 8 10.9 1.2 13.3 8 0.4 0 0.4 0.4 3 5 2 305 4 0 4 0 -20.7 0.1 -20.4 -21 03/28/2005 11:30:00 10.6 1.1 12.6 7.2 10.6 1.1 12.6 7.2 0.4 0 0.4 0.4 2 4 2 305 4 0 4 0 -20.8 0.1 -20.6 -21.3 03/28/2005 11:40:00 10.7 1 12.6 7.6 10.6 1.1 12.6 8 0.4 0 0.4 0.4 2 5 4 305 4 0 4 0 -20.8 0 -20.6 -21 03/28/2005 11:50:00 11 1.1 13 7.2 11 1.2 13.7 7.6 0.4 0 0.4 0.4 3 4 4 305 4 0 4 0 -20.8 0.1 -20.6 -21.1 03/28/2005 12:00:00 10.4 1 13 8 10.4 1 12.6 8 0.4 0 0.4 0.4 2 5 359 305 3 0 4 0 -21.1 0 -20.8 -21.3 03/28/2005 12:10:00 10.4 0.9 12.2 7.6 10.5 1 12.6 7.6 0.4 0 0.4 0.4 3 5 8 305 3 0 4 0 -20.9 0 -20.6 -21.1 03/28/2005 12:20:00 10.4 1 12.6 7.6 10.4 1 12.6 7.2 0.4 0 0.4 0.4 1 5 0 305 3 0 4 0 -20.8 0 -20.8 -21 03/28/2005 12:30:00 10.9 0.9 12.6 8.8 10.8 1 12.6 8 0.4 0 0.4 0.4 0 4 4 305 3 0 3 0 -20.7 0 -20.6 -21 03/28/2005 12:40:00 10.5 1 13 8 10.5 1 13 7.6 0.4 0 0.4 0.4 0 5 0 305 3 0 4 0 -20.7 0 -20.4 -21 03/28/2005 12:50:00 10.4 0.8 11.8 8.4 10.5 0.9 12.6 8 0.4 0 0.4 0.4 359 5 356 305 3 0 3 0 -20.5 0.1 -20.1 -20.8 03/28/2005 13:00:00 10.5 1 12.6 7.2 10.5 1 12.6 7.6 0.4 0 0.4 0.4 1 5 0 305 3 0 3 0 -20.3 0.1 -20.1 -20.6 03/28/2005 13:10:00 10.1 1.1 12.2 7.2 10.1 1.1 12.6 7.6 0.4 0 0.4 0.4 0 5 2 305 3 0 3 0 -20.2 0 -20.1 -20.4 03/28/2005 13:20:00 10.9 1 12.6 7.2 11 1 13 8 0.4 0 0.4 0.4 1 4 0 305 3 0 3 0 -20.2 0 -20.1 -20.4 03/28/2005 13:30:00 11.1 0.8 12.6 8 11.2 0.8 13 8.4 0.4 0 0.4 0.4 2 5 353 305 3 0 3 0 -20.4 0.2 -20.1 -20.8 03/28/2005 13:40:00 10.6 1.1 12.6 6.8 10.7 1.2 13 6.8 0.4 0 0.4 0.4 5 5 3 305 3 0 3 0 -20.2 0.1 -20.1 -20.6 03/28/2005 13:50:00 10 1 12.2 7.2 10 1.1 12.2 7.2 0.4 0 0.4 0.4 3 6 358 305 3 0 3 0 -20.3 0.1 -20.1 -20.6 03/28/2005 14:00:00 10.7 1.1 13 7.6 10.6 1.1 13 7.6 0.4 0 0.4 0.4 3 5 358 305 3 0 3 0 -20.4 0.1 -20.1 -20.8 03/28/2005 14:10:00 11.3 1.1 13.3 8 11.3 1.1 13.3 7.6 0.4 0 0.4 0.4 4 5 3 305 3 0 3 0 -20.3 0.1 -20.1 -20.6 03/28/2005 14:20:00 11.3 0.9 13 8 11.2 0.9 13.7 8.8 0.4 0 0.4 0.4 6 5 7 305 3 0 3 0 -20.2 0 -20.1 -20.6 03/28/2005 14:30:00 11 1 13.3 8.4 11.1 1 13.3 8.4 0.4 0 0.4 0.4 7 5 0 305 3 0 3 0 -20.2 0 -20.1 -20.2 03/28/2005 14:40:00 11.4 0.9 13.3 9.1 11.4 0.9 13.3 8.8 0.4 0 0.4 0.4 7 5 7 305 3 0 3 0 -20.1 0 -19.9 -20.2 03/28/2005 14:50:00 11.5 0.8 13 9.1 11.6 0.9 13.3 8.8 0.4 0 0.4 0.4 5 5 4 305 3 0 3 0 -20.1 0 -19.9 -20.2 03/28/2005 15:00:00 11.2 1 13.3 8.4 11.2 1 13.3 8.4 0.4 0 0.4 0.4 8 4 10 305 3 0 2 0 -20.2 0 -19.9 -20.2 03/28/2005 15:10:00 11.5 0.9 13 9.1 11.6 1 13.3 8.4 0.4 0 0.4 0.4 8 5 7 305 3 0 2 0 -20.2 0.1 -19.9 -20.4 03/28/2005 15:20:00 10.9 0.9 13 8 11 1 13.3 8 0.4 0 0.4 0.4 6 5 7 305 3 0 2 0 -20.1 0.1 -19.9 -20.2 03/28/2005 15:30:00 11.4 0.8 13 9.1 11.3 0.9 13.3 9.1 0.4 0 0.4 0.4 6 4 4 305 2 0 2 0 -20.3 0.1 -20.1 -20.6 03/28/2005 15:40:00 11.3 1 13.3 8.8 11.3 1 13.7 8.4 0.4 0 0.4 0.4 12 5 16 305 2 0 2 0 -20.5 0.1 -20.1 -20.8 03/28/2005 15:50:00 11.1 0.9 13 8.4 11.2 1 13 8.4 0.4 0 0.4 0.4 13 4 21 305 2 0 2 0 -20.6 0.1 -20.2 -20.8 03/28/2005 16:00:00 11.3 1 13.7 8 11.4 1 13.3 8.4 0.4 0 0.4 0.4 13 5 9 305 2 0 2 0 -20.6 0.1 -20.2 -20.8 03/28/2005 16:10:00 11.5 0.9 13.3 8.8 11.6 0.9 13.7 8.8 0.4 0 0.4 0.4 14 6 1 305 2 0 2 0 -20.7 0 -20.4 -21 03/28/2005 16:20:00 12.1 0.9 13.7 8.8 12.1 1 14.1 8.8 0.4 0 0.4 0.4 14 4 19 305 2 0 2 0 -20.8 0 -20.6 -21 03/28/2005 16:30:00 12.3 0.8 14.1 8.8 12.3 1 14.1 8.8 0.4 0 0.4 0.4 15 4 16 305 2 0 2 0 -20.8 0 -20.8 -21 03/28/2005 16:40:00 12.1 1 14.1 9.1 12.2 1 14.9 8.8 0.4 0 0.4 0.4 13 4 12 305 2 0 2 0 -20.7 0 -20.4 -21 03/28/2005 16:50:00 12.6 1 14.5 9.9 12.7 1 14.5 9.9 0.4 0 0.4 0.4 12 4 11 305 2 0 2 0 -20.8 0.1 -20.6 -21.1 03/28/2005 17:00:00 12.3 1 14.1 8.8 12.3 1 14.5 9.1 0.4 0 0.4 0.4 11 5 11 305 2 0 2 0 -20.8 0 -20.6 -21 03/28/2005 17:10:00 12.4 1.1 14.9 9.1 12.5 1.1 14.9 9.1 0.4 0 0.4 0.4 17 4 17 305 2 0 2 0 -20.8 0.1 -20.4 -21 03/28/2005 17:20:00 12.6 1 14.9 9.1 12.7 1 14.5 9.5 0.4 0 0.4 0.4 15 5 13 305 2 0 2 0 -21 0 -20.8 -21.3 03/28/2005 17:30:00 12.3 0.9 14.5 9.1 12.3 1 14.9 9.5 0.4 0 0.4 0.4 20 5 11 305 2 0 2 0 -21 0 -20.8 -21.1 03/28/2005 17:40:00 12 0.9 14.1 9.5 12 1 14.5 9.5 0.4 0 0.4 0.4 15 6 3 305 2 0 2 0 -20.9 0 -20.8 -21.1 03/28/2005 17:50:00 11.9 0.9 14.5 9.1 11.8 1 14.5 8.8 0.4 0 0.4 0.4 18 5 17 305 2 0 2 0 -20.9 0.1 -20.8 -21.1 03/28/2005 18:00:00 11.4 1.1 13.7 8 11.3 1.1 13.7 8.8 0.4 0 0.4 0.4 20 6 23 305 2 0 2 0 -20.8 0 -20.6 -21 03/28/2005 18:10:00 12.1 0.9 14.5 9.9 12 1 14.5 9.5 0.4 0 0.4 0.4 21 6 25 305 2 0 2 0 -20.9 0.1 -20.8 -21.1 03/28/2005 18:20:00 12.4 1 14.9 9.5 12.5 1 15.3 9.1 0.4 0 0.4 0.4 16 5 7 305 2 0 2 0 -21.2 0 -21 -21.3 03/28/2005 18:30:00 11.6 0.9 14.1 8.4 11.7 1.1 14.1 8.4 0.4 0 0.4 0.4 17 5 8 305 2 0 2 0 -21.1 0.1 -20.8 -21.3 03/28/2005 18:40:00 11.2 1 13.3 8.4 11.2 1 13.7 8.4 0.4 0 0.4 0.4 19 5 18 305 2 0 2 0 -21.2 0 -21 -21.3 03/28/2005 18:50:00 11.2 1 13.3 8 11.1 1 13.7 8 0.4 0 0.4 0.4 14 6 13 305 2 0 2 0 -21.3 0 -21 -21.5 03/28/2005 19:00:00 11.6 1.1 13.7 8.8 11.6 1.2 14.1 8.8 0.4 0 0.4 0.4 12 4 15 305 2 0 2 0 -21.3 0 -21 -21.3 03/28/2005 19:10:00 11.2 1.5 14.1 7.2 11.2 1.5 14.1 7.6 0.4 0 0.4 0.4 14 5 14 305 2 0 1 0 -21.4 0.1 -21.3 -21.7 03/28/2005 19:20:00 11.6 1.1 13.7 8.4 11.6 1.1 14.1 8.4 0.4 0 0.4 0.4 12 5 13 305 2 0 2 0 -21.6 0.1 -21.3 -21.8 03/28/2005 19:30:00 12 1.1 13.7 8 11.9 1.1 14.1 9.1 0.4 0 0.4 0.4 14 4 11 305 2 0 2 0 -21.8 0.1 -21.5 -22.2 03/28/2005 19:40:00 11.8 1 14.1 8.4 11.5 1.1 14.5 8.8 0.4 0 0.4 0.4 11 6 15 305 1 0 1 0 -22.2 0 -21.8 -22.4 03/28/2005 19:50:00 12.1 0.9 14.1 9.5 12 1 14.1 9.1 0.4 0 0.4 0.4 15 4 14 305 1 0 1 0 -22.3 0 -22 -22.5 03/28/2005 20:00:00 11.7 0.8 13.3 9.1 11.7 0.8 13.3 9.5 0.4 0 0.4 0.4 12 4 11 305 1 0 1 0 -22.5 0.1 -22 -22.7 03/28/2005 20:10:00 11.1 1 13 8.8 11.1 1 13 8.4 0.4 0 0.4 0.4 12 5 17 305 1 0 1 0 -22.6 0 -22.5 -22.7 03/28/2005 20:20:00 9.9 1 12.6 7.2 9.9 1 12.2 7.2 0.4 0 0.4 0.4 13 6 19 305 1 0 1 0 -22.5 0.1 -22.4 -22.7 03/28/2005 20:30:00 9.8 1 11.8 6.8 9.7 1.1 11.8 6.1 0.4 0 0.4 0.4 14 6 21 305 1 0 1 0 -22.6 0 -22.4 -22.7 03/28/2005 20:40:00 10.6 0.9 12.6 7.6 10.7 0.9 12.6 8 0.4 0 0.4 0.4 10 5 12 305 1 0 1 0 -22.7 0.1 -22 -22.9 03/28/2005 20:50:00 10.2 1 13 7.2 10.2 1.1 12.6 7.2 0.4 0 0.4 0.4 12 6 9 305 1 0 1 0 -22.9 0 -22.5 -23 03/28/2005 21:00:00 9.7 1 11.8 6.1 9.7 1.1 11.8 6.1 0.4 0 0.4 0.4 14 7 11 305 1 0 1 0 -22.9 0 -22.5 -23 03/28/2005 21:10:00 10.5 0.9 11.8 7.6 10.4 1 12.2 7.2 0.4 0 0.4 0.4 14 6 7 305 1 0 1 0 -22.9 0.2 -22.5 -23.2 03/28/2005 21:20:00 9.9 0.8 11.8 7.2 9.9 0.8 12.2 7.2 0.4 0 0.4 0.4 22 5 20 305 2 0 1 0 -23 0.2 -22.4 -23.2 03/28/2005 21:30:00 10.4 0.8 12.2 8 10.3 0.9 12.2 8 0.4 0 0.4 0.4 21 6 30 305 2 0 2 0 -23.1 0.2 -22.5 -23.4 03/28/2005 21:40:00 9.8 1 11.8 7.2 9.8 1.1 11.5 7.2 0.4 0 0.4 0.4 22 5 19 305 2 0 2 0 -23.2 0.2 -22.7 -23.4 03/28/2005 21:50:00 9.6 0.9 11.8 7.6 9.5 0.9 11.8 7.2 0.4 0 0.4 0.4 23 6 37 305 2 0 2 0 -23.3 0 -22.9 -23.4 03/28/2005 22:00:00 9.5 0.8 11.1 7.6 9.3 0.8 11.5 6.8 0.4 0 0.4 0.4 26 6 27 305 2 0 2 0 -23.4 0 -22.9 -23.4 03/28/2005 22:10:00 9.1 0.8 10.7 7.2 9.2 0.8 11.1 6.8 0.4 0 0.4 0.4 23 6 17 305 2 0 2 0 -23.4 0 -23.4 -23.6 03/28/2005 22:20:00 9.3 0.8 11.1 7.6 9.3 0.8 11.1 7.2 0.4 0 0.4 0.4 24 6 18 305 2 0 2 0 -23.5 0 -23.4 -23.7 03/28/2005 22:30:00 9.1 0.9 11.1 6.8 9 0.9 11.1 6.8 0.4 0 0.4 0.4 26 8 15 305 2 0 1 0 -23.5 0 -23.4 -23.7 03/28/2005 22:40:00 8.9 1 10.7 6.5 8.8 1 11.1 5.7 0.4 0 0.4 0.4 37 6 31 305 2 0 2 0 -23.6 0.1 -23.4 -23.7 03/28/2005 22:50:00 8.2 0.8 9.9 6.1 8.1 0.8 9.9 5.7 0.4 0 0.4 0.4 31 6 34 305 2 0 2 0 -23.6 0 -23.2 -23.7 03/28/2005 23:00:00 8.3 0.6 9.9 6.8 8.2 0.7 9.5 6.5 0.4 0 0.4 0.4 32 6 28 305 2 0 2 0 -23.6 0 -23.2 -23.9 03/28/2005 23:10:00 8.6 0.5 10.3 6.8 8.5 0.6 9.9 7.2 0.4 0 0.4 0.4 42 4 41 305 2 0 2 0 -23.7 0 -23.4 -23.9 03/28/2005 23:20:00 8.5 0.9 10.7 6.1 8.4 1 10.7 5.7 0.4 0 0.4 0.4 32 6 25 305 2 0 2 0 -23.7 0.1 -23.4 -23.9 03/28/2005 23:30:00 8.8 0.7 10.7 6.8 8.7 0.7 10.7 6.8 0.4 0 0.4 0.4 34 6 35 305 2 0 2 0 -23.9 0 -23.9 -24.1 03/28/2005 23:40:00 9 0.7 10.7 6.8 9 0.8 11.1 6.8 0.4 0 0.4 0.4 33 6 33 305 2 0 2 0 -24 0 -23.4 -24.2 03/28/2005 23:50:00 8.7 0.7 10.3 6.8 8.6 0.6 9.9 6.8 0.4 0 0.4 0.4 35 4 41 305 2 0 2 0 -24.2 0.1 -23.9 -24.4 03/29/2005 00:00:00 8.8 0.6 9.9 7.2 8.7 0.7 10.3 6.8 0.4 0 0.4 0.4 34 5 39 305 2 0 2 0 -24.2 0.2 -23.9 -24.6 03/29/2005 00:10:00 8.5 0.7 10.3 6.8 8.3 0.7 10.3 6.5 0.4 0 0.4 0.4 35 6 35 305 2 0 2 0 -24.4 0.2 -23.9 -24.6 03/29/2005 00:20:00 8.7 0.6 9.9 6.8 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 35 4 31 305 2 0 2 0 -24.4 0.1 -23.9 -24.6 03/29/2005 00:30:00 8 0.6 9.5 6.1 8 0.6 9.5 6.1 0.4 0 0.4 0.4 27 8 21 305 2 0 1 0 -24.5 0.2 -24.1 -24.7 03/29/2005 00:40:00 8.2 0.8 9.5 6.1 8.2 0.8 9.9 6.1 0.4 0 0.4 0.4 29 5 32 305 2 0 2 0 -24.7 0.1 -24.2 -24.9 03/29/2005 00:50:00 8.3 0.8 10.7 6.5 8.3 0.8 10.3 6.1 0.4 0 0.4 0.4 30 5 30 305 2 0 2 0 -24.9 0.2 -24.6 -25.1 03/29/2005 01:00:00 7.8 0.6 9.5 6.1 7.8 0.7 9.1 5.7 0.4 0 0.4 0.4 33 6 36 305 2 0 1 0 -24.9 0.2 -24.6 -25.1 03/29/2005 01:10:00 8.4 0.8 10.3 6.1 8.3 0.9 10.3 6.1 0.4 0 0.4 0.4 31 5 34 305 2 0 1 0 -24.9 0.1 -24.6 -25.2 03/29/2005 01:20:00 8.7 0.6 10.3 7.2 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 32 5 27 305 2 0 2 0 -25 0.1 -24.6 -25.2 03/29/2005 01:30:00 8.5 0.9 10.3 6.1 8.4 1 9.9 5.7 0.4 0 0.4 0.4 35 3 39 305 2 0 1 0 -25.1 0.1 -24.7 -25.2 03/29/2005 01:40:00 8.2 0.6 9.5 6.5 8.1 0.7 10.3 6.5 0.4 0 0.4 0.4 33 5 40 305 2 0 1 0 -25.1 0.1 -24.7 -25.2 03/29/2005 01:50:00 8.4 0.6 9.5 6.8 8.2 0.7 9.5 6.8 0.4 0 0.4 0.4 32 5 30 305 1 0 1 0 -25.2 0.1 -24.7 -25.2 03/29/2005 02:00:00 8.8 0.5 10.3 7.6 8.8 0.6 10.3 7.6 0.4 0 0.4 0.4 34 4 42 305 1 0 2 0 -25.2 0.2 -24.7 -25.4 03/29/2005 02:10:00 8.5 0.7 10.3 6.5 8.4 0.8 10.7 6.5 0.4 0 0.4 0.4 35 5 31 305 1 0 1 0 -25.2 0.2 -24.7 -25.4 03/29/2005 02:20:00 9.1 0.7 11.1 7.6 9 0.7 11.1 7.6 0.4 0 0.4 0.4 33 4 31 305 1 0 2 0 -25.2 0.2 -24.7 -25.6 03/29/2005 02:30:00 7.9 0.6 9.1 6.5 7.8 0.7 9.5 6.1 0.4 0 0.4 0.4 35 4 29 305 1 0 1 0 -25.3 0.2 -24.7 -25.6 03/29/2005 02:40:00 8.5 0.5 9.5 6.8 8.4 0.5 9.9 6.8 0.4 0 0.4 0.4 29 6 32 305 1 0 1 0 -25.4 0.2 -25.1 -25.7 03/29/2005 02:50:00 8.4 0.7 10.3 6.8 8.3 0.7 10.3 6.5 0.4 0 0.4 0.4 27 4 25 305 1 0 1 0 -25.5 0.1 -25.1 -25.7 03/29/2005 03:00:00 9.6 0.7 11.1 7.6 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 32 3 37 305 1 0 1 0 -25.5 0.1 -25.1 -25.7 03/29/2005 03:10:00 9.3 0.6 10.7 7.2 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 34 4 37 305 1 0 1 0 -25.6 0.1 -25.2 -25.9 03/29/2005 03:20:00 8.8 0.7 10.3 6.5 8.7 0.7 10.3 6.8 0.4 0 0.4 0.4 31 6 26 305 1 0 2 0 -25.6 0.1 -25.2 -25.9 03/29/2005 03:30:00 9.3 0.6 10.7 7.6 9.2 0.6 11.1 7.2 0.4 0 0.4 0.4 38 5 33 305 1 0 1 0 -25.6 0.1 -25.1 -25.7 03/29/2005 03:40:00 8.9 0.6 10.3 7.2 8.9 0.7 10.3 6.8 0.4 0 0.4 0.4 40 5 50 305 1 0 1 0 -25.6 0.1 -25.1 -25.7 03/29/2005 03:50:00 8.4 0.7 9.9 6.5 8.4 0.8 9.9 6.1 0.4 0 0.4 0.4 35 7 51 305 1 0 1 0 -25.6 0.2 -25.1 -25.7 03/29/2005 04:00:00 8.2 0.8 9.9 6.5 8.1 0.8 9.9 5.7 0.4 0 0.4 0.4 34 7 27 305 1 0 1 0 -25.6 0.1 -25.1 -25.9 03/29/2005 04:10:00 8.2 1 10.3 5.7 8.2 1 10.7 5.7 0.4 0 0.4 0.4 34 7 44 305 1 0 1 0 -25.6 0.1 -25.1 -25.9 03/29/2005 04:20:00 8.2 0.7 9.9 6.1 8.2 0.7 9.9 6.1 0.4 0 0.4 0.4 39 6 39 305 1 0 1 0 -25.6 0.1 -25.2 -25.9 03/29/2005 04:30:00 8 0.7 9.5 6.5 8 0.7 9.5 6.5 0.4 0 0.4 0.4 32 7 41 305 1 0 2 0 -25.6 0.1 -25.2 -25.9 03/29/2005 04:40:00 8.1 0.7 9.5 6.5 8.1 0.7 9.9 6.5 0.4 0 0.4 0.4 35 5 35 305 1 0 1 0 -25.7 0.2 -25.2 -25.9 03/29/2005 04:50:00 7.8 0.5 9.5 6.1 7.7 0.6 9.5 6.1 0.4 0 0.4 0.4 36 7 38 305 1 0 2 0 -25.8 0.2 -25.2 -26.1 03/29/2005 05:00:00 7.6 0.8 9.1 5.3 7.5 0.8 9.5 5.3 0.4 0 0.4 0.4 33 7 41 305 1 0 1 0 -25.9 0.2 -25.2 -26.1 03/29/2005 05:10:00 7.2 0.8 9.1 5.3 7.1 0.9 9.5 4.9 0.4 0 0.4 0.4 41 7 40 305 1 0 1 0 -26 0.1 -25.6 -26.1 03/29/2005 05:20:00 6.9 0.6 8.4 5.3 6.8 0.6 8.8 5.3 0.4 0 0.4 0.4 36 8 27 305 1 0 2 0 -25.9 0.1 -25.6 -26.1 03/29/2005 05:30:00 7.4 0.9 9.5 4.6 7.2 1 9.5 4.6 0.4 0 0.4 0.4 31 8 27 305 1 0 1 0 -25.9 0.1 -25.6 -26.1 03/29/2005 05:40:00 7.7 0.9 9.9 4.9 7.5 0.9 9.5 4.6 0.4 0 0.4 0.4 32 7 36 305 1 0 2 0 -25.9 0.1 -25.6 -26.1 03/29/2005 05:50:00 8 0.9 10.7 5.7 7.8 0.9 9.9 5.7 0.4 0 0.4 0.4 33 8 36 305 1 0 1 0 -25.9 0.2 -25.6 -26.1 03/29/2005 06:00:00 8.9 0.8 10.7 6.8 8.8 0.8 10.7 6.8 0.4 0 0.4 0.4 34 5 30 305 1 0 1 0 -26 0.1 -25.6 -26.2 03/29/2005 06:10:00 7.4 0.8 9.9 5.3 7.2 0.8 9.9 5.3 0.4 0 0.4 0.4 31 7 30 305 1 0 1 0 -26 0.1 -25.6 -26.2 03/29/2005 06:20:00 7.7 0.7 9.5 5.3 7.5 0.7 9.1 4.9 0.4 0 0.4 0.4 28 6 29 305 1 0 1 0 -26 0.1 -25.6 -26.1 03/29/2005 06:30:00 7.7 1 9.5 4.6 7.6 1 9.5 4.9 0.4 0 0.4 0.4 30 6 29 305 1 0 1 0 -26 0.1 -25.6 -26.1 03/29/2005 06:40:00 7.9 0.6 9.5 6.1 7.7 0.7 8.8 5.7 0.4 0 0.4 0.4 33 5 35 305 1 0 1 0 -26 0.2 -25.6 -26.1 03/29/2005 06:50:00 7.9 0.8 9.9 5.7 7.8 0.8 9.9 5.3 0.4 0 0.4 0.4 32 5 35 305 1 0 2 0 -26 0.2 -25.6 -26.1 03/29/2005 07:00:00 7.8 0.8 9.1 5.7 7.6 0.8 9.1 4.9 0.4 0 0.4 0.4 32 5 31 305 1 0 2 0 -25.9 0.1 -25.4 -26.1 03/29/2005 07:10:00 7.9 0.6 9.1 6.1 7.8 0.6 8.8 5.7 0.4 0 0.4 0.4 30 6 33 305 1 0 1 0 -25.9 0.1 -25.4 -26.1 03/29/2005 07:20:00 7.9 0.8 9.9 5.7 7.8 1 9.5 5.3 0.4 0 0.4 0.4 33 6 33 305 1 0 1 0 -26 0.1 -25.6 -26.1 03/29/2005 07:30:00 8.3 0.8 9.9 6.1 8.1 0.8 9.9 6.1 0.4 0 0.4 0.4 35 5 30 305 1 0 1 0 -26 0.1 -25.6 -26.1 03/29/2005 07:40:00 7.9 0.5 9.1 6.5 7.7 0.6 8.8 6.1 0.4 0 0.4 0.4 34 4 35 305 1 0 1 0 -26 0.1 -25.6 -26.1 03/29/2005 07:50:00 7.1 0.5 8 5.7 7 0.6 8.4 5.3 0.4 0 0.4 0.4 36 6 36 305 1 0 1 0 -26 0.1 -25.6 -26.1 03/29/2005 08:00:00 6.8 0.6 8 4.9 6.7 0.6 8 5.3 0.4 0 0.4 0.4 32 5 35 305 1 0 1 0 -25.9 0.1 -25.4 -26.1 03/29/2005 08:10:00 6.3 0.8 8 4.6 6.3 0.8 8 4.2 0.4 0 0.4 0.4 31 7 41 305 1 0 1 0 -25.9 0.2 -25.4 -26.1 03/29/2005 08:20:00 6.8 0.8 8.8 4.6 6.7 0.8 8.4 4.2 0.4 0 0.4 0.4 32 8 35 305 2 0 1 0 -25.9 0.2 -25.4 -26.1 03/29/2005 08:30:00 7 0.6 8 5.3 6.9 0.6 8.4 4.9 0.4 0 0.4 0.4 33 6 35 305 2 0 2 0 -25.9 0.2 -25.2 -26.1 03/29/2005 08:40:00 7.2 0.8 8.8 4.9 7.1 0.8 8.8 4.9 0.4 0 0.4 0.4 31 6 18 305 2 0 2 0 -25.8 0.2 -25.2 -26.1 03/29/2005 08:50:00 7.2 0.8 8.8 5.3 7.1 0.8 8.8 4.9 0.4 0 0.4 0.4 32 5 32 305 2 0 2 0 -25.9 0.2 -25.2 -26.1 03/29/2005 09:00:00 6.5 0.7 8 4.9 6.5 0.7 8 4.9 0.4 0 0.4 0.4 26 7 27 305 2 0 1 0 -25.9 0.1 -25.4 -26.1 03/29/2005 09:10:00 6.3 0.6 7.6 4.9 6.2 0.7 7.6 4.6 0.4 0 0.4 0.4 30 6 25 305 2 0 1 0 -25.7 0.1 -25.2 -26.1 03/29/2005 09:20:00 6.1 0.6 7.6 4.6 5.9 0.6 7.6 4.6 0.4 0 0.4 0.4 32 7 36 305 2 0 2 0 -25.6 0.2 -25.2 -25.9 03/29/2005 09:30:00 6.7 0.8 8.4 3.8 6.6 0.8 8.4 4.6 0.4 0 0.4 0.4 23 6 25 305 2 0 2 0 -25.6 0.2 -25.1 -25.9 03/29/2005 09:40:00 7 0.9 8.8 4.6 7 1 8.8 4.6 0.4 0 0.4 0.4 23 5 27 305 2 0 2 0 -25.7 0.1 -25.2 -25.9 03/29/2005 09:50:00 7.1 0.8 9.1 4.9 6.9 0.9 9.1 4.6 0.4 0 0.4 0.4 22 6 23 305 2 0 2 0 -25.5 0.1 -25.1 -25.7 03/29/2005 10:00:00 8.1 0.8 10.3 5.3 8 0.8 9.9 5.7 0.4 0 0.4 0.4 19 6 21 305 2 0 1 0 -25.6 0.1 -25.2 -25.7 03/29/2005 10:10:00 8 0.8 9.5 5.7 8 0.9 9.5 5.3 0.4 0 0.4 0.4 18 6 25 305 2 0 2 0 -25.6 0.1 -25.1 -25.7 03/29/2005 10:20:00 8 0.9 9.9 5.3 8 0.9 9.9 5.7 0.4 0 0.4 0.4 18 6 21 305 2 0 1 0 -25.5 0.2 -24.7 -25.6 03/29/2005 10:30:00 8.5 0.6 9.9 6.5 8.4 0.7 9.9 6.5 0.4 0 0.4 0.4 16 5 13 305 2 0 1 0 -25.3 0.1 -24.7 -25.6 03/29/2005 10:40:00 8.9 0.7 10.7 6.5 8.9 0.7 10.3 6.5 0.4 0 0.4 0.4 15 5 13 305 2 0 2 0 -25.2 0.1 -24.6 -25.4 03/29/2005 10:50:00 8.5 0.8 10.3 6.1 8.4 0.9 10.3 6.1 0.4 0 0.4 0.4 16 5 19 305 2 0 1 0 -25.1 0.1 -24.6 -25.2 03/29/2005 11:00:00 8.5 0.8 10.3 6.5 8.5 0.8 10.3 6.1 0.4 0 0.4 0.4 17 6 9 305 2 0 1 0 -25 0 -24.9 -25.2 03/29/2005 11:10:00 8.8 0.8 10.7 6.5 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 17 5 19 305 1 0 1 0 -25 0 -24.7 -25.2 03/29/2005 11:20:00 9 0.6 10.7 7.2 9.1 0.7 10.3 7.2 0.4 0 0.4 0.4 12 5 7 305 1 0 2 0 -25 0 -24.6 -25.1 03/29/2005 11:30:00 8.8 0.8 10.7 6.1 8.8 0.9 10.3 6.5 0.4 0 0.4 0.4 17 5 17 305 1 0 1 0 -24.9 0.1 -24.4 -25.1 03/29/2005 11:40:00 8.6 1 10.3 5.3 8.6 1 10.7 5.3 0.4 0 0.4 0.4 14 7 20 305 1 0 1 0 -24.8 0.1 -23.9 -25.1 03/29/2005 11:50:00 9 0.7 10.7 7.2 9 0.8 11.1 6.5 0.4 0 0.4 0.4 16 5 17 305 1 0 1 0 -24.7 0.1 -23.9 -24.9 03/29/2005 12:00:00 8.5 0.7 10.3 6.5 8.5 0.8 10.3 6.1 0.4 0 0.4 0.4 15 6 16 305 1 0 1 0 -24.5 0.1 -24.2 -24.7 03/29/2005 12:10:00 8.6 0.8 10.3 6.1 8.6 0.8 10.3 5.7 0.4 0 0.4 0.4 12 6 7 305 1 0 1 0 -24.4 0.1 -23.9 -24.6 03/29/2005 12:20:00 8.5 0.6 9.9 6.5 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 4 6 4 305 1 0 1 0 -24.4 0 -24.2 -24.6 03/29/2005 12:30:00 8.6 0.6 9.9 6.8 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 9 4 7 305 1 0 1 0 -24.4 0 -24.1 -24.6 03/29/2005 12:40:00 8.3 0.7 10.3 5.7 8.4 0.7 10.3 6.1 0.4 0 0.4 0.4 3 6 2 305 1 0 1 0 -24.3 0.1 -23.9 -24.6 03/29/2005 12:50:00 8.4 0.7 10.3 6.1 8.4 0.8 10.3 5.7 0.4 0 0.4 0.4 6 5 359 305 1 0 1 0 -24.1 0.1 -23.9 -24.4 03/29/2005 13:00:00 8.9 0.6 10.3 6.5 9 0.7 10.7 6.5 0.4 0 0.4 0.4 1 5 5 305 1 0 1 0 -24.3 0 -24.2 -24.6 03/29/2005 13:10:00 8.9 0.8 10.7 6.5 9 0.8 10.7 6.1 0.4 0 0.4 0.4 2 5 4 305 1 0 1 0 -24.1 0.1 -23.9 -24.6 03/29/2005 13:20:00 8.4 0.9 10.7 6.1 8.4 0.9 10.7 6.5 0.4 0 0.4 0.4 3 5 4 305 1 0 1 0 -23.9 0.1 -23.7 -24.2 03/29/2005 13:30:00 8.5 0.7 10.3 6.5 8.5 0.8 10.3 6.1 0.4 0 0.4 0.4 7 6 9 305 1 0 1 0 -23.8 0.1 -23.4 -23.9 03/29/2005 13:40:00 8.9 0.8 10.3 6.5 9.1 0.8 11.1 6.5 0.4 0 0.4 0.4 2 4 4 305 1 0 1 0 -23.8 0.1 -23.6 -23.9 03/29/2005 13:50:00 8.9 0.9 11.1 6.8 9 0.9 11.1 7.2 0.4 0 0.4 0.4 5 7 10 305 1 0 1 0 -23.7 0.1 -23.4 -23.9 03/29/2005 14:00:00 8.8 1 11.1 6.1 8.8 1 10.7 6.1 0.4 0 0.4 0.4 2 5 5 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 03/29/2005 14:10:00 8.8 0.9 11.5 6.8 8.8 0.9 11.1 6.5 0.4 0 0.4 0.4 0 6 3 305 1 0 1 0 -23.5 0 -23.2 -23.9 03/29/2005 14:20:00 9.2 0.8 10.7 7.2 9.2 0.9 11.5 6.5 0.4 0 0.4 0.4 4 7 5 305 1 0 1 0 -23.6 0.1 -23.2 -23.9 03/29/2005 14:30:00 9.1 0.9 11.1 6.5 9.2 0.9 11.5 6.5 0.4 0 0.4 0.4 3 6 3 305 1 0 1 0 -23.4 0.1 -22.9 -23.7 03/29/2005 14:40:00 8.9 0.9 11.1 6.8 8.9 1 11.1 6.1 0.4 0 0.4 0.4 9 6 9 305 1 0 1 0 -23.5 0 -23.2 -23.7 03/29/2005 14:50:00 9.1 0.7 11.1 7.2 9.1 0.8 11.1 7.2 0.4 0 0.4 0.4 5 6 10 305 1 0 1 0 -23.4 0 -23.2 -23.6 03/29/2005 15:00:00 9 1 11.1 6.1 9.1 1.1 11.5 6.1 0.4 0 0.4 0.4 3 6 11 305 1 0 1 0 -23.4 0 -23.2 -23.6 03/29/2005 15:10:00 9 1 11.1 6.5 9 1 11.1 6.5 0.4 0 0.4 0.4 4 5 3 305 1 0 1 0 -23.5 0 -23.4 -23.7 03/29/2005 15:20:00 8.6 0.8 10.3 6.5 8.7 0.8 10.3 6.5 0.4 0 0.4 0.4 1 7 356 305 1 0 1 0 -23.3 0.1 -23 -23.6 03/29/2005 15:30:00 9.1 0.8 10.7 6.8 9.2 0.8 11.1 6.8 0.4 0 0.4 0.4 3 6 9 305 1 0 1 0 -23.5 0.1 -23 -23.9 03/29/2005 15:40:00 9.7 0.6 11.1 7.6 9.7 0.7 11.5 7.6 0.4 0 0.4 0.4 1 7 352 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 03/29/2005 15:50:00 9.1 0.8 11.5 6.8 9.1 0.9 11.5 6.8 0.4 0 0.4 0.4 5 7 3 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 03/29/2005 16:00:00 9 0.8 11.1 7.2 9.1 0.8 11.1 7.2 0.4 0 0.4 0.4 357 6 358 305 1 0 1 0 -23.5 0 -23.2 -23.7 03/29/2005 16:10:00 9.3 0.9 11.1 7.2 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 357 6 1 305 1 0 1 0 -23.4 0 -23.2 -23.7 03/29/2005 16:20:00 9.4 0.8 11.5 7.2 9.5 0.8 11.8 7.2 0.4 0 0.4 0.4 352 5 348 305 1 0 1 0 -23.3 0 -23.2 -23.4 03/29/2005 16:30:00 9.4 0.8 11.5 7.2 9.5 0.8 11.8 7.2 0.4 0 0.4 0.4 357 5 356 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 03/29/2005 16:40:00 9.6 0.6 11.1 7.6 9.8 0.7 11.5 7.6 0.4 0 0.4 0.4 356 5 350 305 1 0 1 0 -23.4 0 -23.2 -23.6 03/29/2005 16:50:00 9.1 0.8 11.5 6.8 9.2 0.9 11.5 6.1 0.4 0 0.4 0.4 354 6 353 305 1 0 1 0 -23.4 0 -23.2 -23.6 03/29/2005 17:00:00 9.4 0.8 11.5 7.2 9.5 1 11.8 6.8 0.4 0 0.4 0.4 0 8 0 305 1 0 1 0 -23.5 0 -23.2 -23.7 03/29/2005 17:10:00 9.5 0.8 11.5 7.6 9.7 0.8 11.8 7.2 0.4 0 0.4 0.4 356 6 3 305 1 0 1 0 -23.4 0 -23.2 -23.6 03/29/2005 17:20:00 9.8 1 11.8 7.2 9.8 1 12.2 7.6 0.4 0 0.4 0.4 1 7 0 305 1 0 1 0 -23.5 0 -23.2 -23.9 03/29/2005 17:30:00 10.2 1 11.8 7.2 10.3 1 12.2 7.2 0.4 0 0.4 0.4 353 6 357 305 1 0 1 0 -23.5 0.1 -23.2 -23.9 03/29/2005 17:40:00 10.1 0.9 12.2 7.6 10.2 0.9 12.6 8 0.4 0 0.4 0.4 356 6 353 305 1 0 1 0 -23.4 0 -23.2 -23.6 03/29/2005 17:50:00 10.3 1 12.2 8 10.5 1 12.6 8.4 0.4 0 0.4 0.4 355 5 346 305 1 0 1 0 -23.5 0 -23.2 -23.7 03/29/2005 18:00:00 10.2 1 13.7 7.6 10.3 1.1 13.7 6.8 0.4 0 0.4 0.4 353 6 352 305 1 0 1 0 -23.4 0 -23.2 -23.6 03/29/2005 18:10:00 10.1 1 12.6 7.6 10.2 1 12.6 8 0.4 0 0.4 0.4 357 7 347 305 1 0 1 0 -23.5 0 -23.2 -23.6 03/29/2005 18:20:00 10.4 0.9 13 8.4 10.4 1 13.3 8 0.4 0 0.4 0.4 357 8 359 305 1 0 1 0 -23.6 0.1 -23.4 -23.7 03/29/2005 18:30:00 10.9 0.8 13 8.8 11 0.9 13.7 8.8 0.4 0 0.4 0.4 1 6 355 305 1 0 1 0 -23.7 0.1 -23.4 -23.9 03/29/2005 18:40:00 10.7 0.9 13 8 10.7 1 13.3 8 0.4 0 0.4 0.4 3 5 5 305 1 0 1 0 -23.8 0 -23.6 -23.9 03/29/2005 18:50:00 10.7 1 13 8 10.8 1 13.3 8.4 0.4 0 0.4 0.4 0 6 8 305 1 0 1 0 -24 0.1 -23.7 -24.2 03/29/2005 19:00:00 11 0.8 12.6 8.4 11 1 13.3 8.4 0.4 0 0.4 0.4 359 5 8 305 1 0 1 0 -24 0 -23.9 -24.2 03/29/2005 19:10:00 10.8 1.2 13 8.4 10.8 1.3 13.3 8 0.4 0 0.4 0.4 357 6 1 305 1 0 1 0 -23.9 0 -23.7 -24.1 03/29/2005 19:20:00 10.9 1 13 8 11 1.1 13.3 7.6 0.4 0 0.4 0.4 1 6 1 305 1 0 1 0 -24 0 -23.9 -24.2 03/29/2005 19:30:00 11.4 1 13.3 9.1 11.4 1.1 13.7 8 0.4 0 0.4 0.4 0 6 347 305 1 0 1 0 -24.2 0 -23.9 -24.4 03/29/2005 19:40:00 11.5 1.2 14.1 8 11.6 1.3 14.5 8.4 0.4 0 0.4 0.4 2 6 0 305 1 0 1 0 -24.1 0.1 -23.9 -24.6 03/29/2005 19:50:00 11.7 1.1 14.1 8.8 11.6 1.2 14.1 8.4 0.4 0 0.4 0.4 0 5 0 305 1 0 1 0 -24.4 0.1 -24.2 -24.6 03/29/2005 20:00:00 11.7 1.2 14.1 7.6 11.8 1.3 14.9 8.4 0.4 0 0.4 0.4 2 5 0 305 1 0 1 0 -24.5 0 -24.1 -24.6 03/29/2005 20:10:00 11.7 1 13.7 8 11.9 1.1 14.1 8 0.4 0 0.4 0.4 2 5 359 305 1 0 1 0 -24.6 0.2 -24.1 -24.9 03/29/2005 20:20:00 11.6 1 14.1 8.4 11.7 1.1 14.1 8.8 0.4 0 0.4 0.4 2 6 4 305 1 0 1 0 -24.5 0.2 -24.1 -24.7 03/29/2005 20:30:00 11.8 1.1 14.5 8.8 11.8 1.1 15.3 8.8 0.4 0 0.4 0.4 3 5 3 305 1 0 1 0 -24.7 0.1 -24.2 -24.9 03/29/2005 20:40:00 11.5 1.2 14.1 8 11.5 1.3 14.1 8.4 0.4 0 0.4 0.4 3 5 8 305 1 0 1 0 -24.8 0.1 -24.2 -24.9 03/29/2005 20:50:00 11.5 1 13.3 8.8 11.5 1 13.7 9.1 0.4 0 0.4 0.4 0 4 0 305 1 0 1 0 -24.8 0.1 -24.4 -25.1 03/29/2005 21:00:00 11.6 1 14.1 8.8 11.5 1 14.1 9.1 0.4 0 0.4 0.4 0 5 357 305 1 0 1 0 -24.9 0.1 -24.6 -25.1 03/29/2005 21:10:00 11 1.1 13.7 8.8 11.2 1.1 14.1 8.8 0.4 0 0.4 0.4 357 5 1 305 1 0 1 0 -24.9 0.1 -24.6 -25.1 03/29/2005 21:20:00 10.8 1.1 13 7.6 10.7 1.1 13.3 8 0.4 0 0.4 0.4 357 5 358 305 1 0 1 0 -24.9 0.1 -24.6 -25.1 03/29/2005 21:30:00 10.6 1.1 13 7.6 10.5 1 13 7.6 0.4 0 0.4 0.4 354 5 353 305 1 0 1 0 -24.9 0.1 -24.6 -25.1 03/29/2005 21:40:00 10.2 1 12.2 8 10.2 1 12.6 8 0.4 0 0.4 0.4 354 5 356 305 1 0 1 0 -24.9 0.1 -24.6 -25.1 03/29/2005 21:50:00 10.3 1 12.2 7.6 10.5 1 12.6 7.6 0.4 0 0.4 0.4 352 4 356 305 1 0 1 0 -24.9 0.1 -24.6 -25.2 03/29/2005 22:00:00 10.8 0.9 13 8.8 10.8 1 13.3 8.8 0.4 0 0.4 0.4 352 4 354 305 1 0 1 0 -24.9 0.1 -24.6 -25.2 03/29/2005 22:10:00 10.8 1 13 8 10.9 1.1 13.3 8.4 0.4 0 0.4 0.4 350 4 348 305 1 0 1 0 -24.9 0.1 -24.6 -25.2 03/29/2005 22:20:00 10.4 1 12.6 7.6 10.7 1 13 8.4 0.4 0 0.4 0.4 350 5 345 305 1 0 1 0 -25 0.1 -24.6 -25.1 03/29/2005 22:30:00 10.3 0.9 12.6 8 10.5 0.9 13 8.4 0.4 0 0.4 0.4 349 5 345 305 1 0 1 0 -24.9 0.1 -24.6 -25.1 03/29/2005 22:40:00 11.2 0.8 13 8.8 10.9 0.9 12.6 8.8 0.4 0 0.4 0.4 347 3 345 305 1 0 1 0 -24.9 0.1 -24.4 -25.1 03/29/2005 22:50:00 10.4 1.1 13 7.2 10.5 1.2 13 6.8 0.4 0 0.4 0.4 350 5 343 305 1 0 1 0 -24.8 0.1 -24.6 -25.1 03/29/2005 23:00:00 10.5 1.1 13 7.6 10.6 1.1 13.3 7.6 0.4 0 0.4 0.4 349 6 355 305 1 0 1 0 -24.9 0.1 -24.6 -25.1 03/29/2005 23:10:00 11.5 1 13.7 8.4 11.5 1.1 14.1 8.4 0.4 0 0.4 0.4 347 5 350 305 1 0 1 0 -24.9 0.1 -24.6 -25.1 03/29/2005 23:20:00 10.5 1.2 13.3 7.6 10.6 1.3 13.3 7.2 0.4 0 0.4 0.4 350 5 348 305 1 0 1 0 -24.9 0.1 -24.6 -25.1 03/29/2005 23:30:00 11.1 1 13.3 8 10.9 1 13.3 8 0.4 0 0.4 0.4 350 4 348 305 1 0 1 0 -25 0.1 -24.6 -25.2 03/29/2005 23:40:00 11.4 1 13.3 8.8 11.1 1.2 14.5 8.8 0.4 0 0.4 0.4 350 4 351 305 1 0 1 0 -25 0.1 -24.6 -25.2 03/29/2005 23:50:00 11.1 1.1 13.3 8 11.1 1.2 13.7 8.4 0.4 0 0.4 0.4 348 5 346 305 1 0 1 0 -25.2 0.1 -24.7 -25.4 03/30/2005 00:00:00 11.2 0.9 13 8.8 11.2 1 13.3 8.8 0.4 0 0.4 0.4 347 5 345 305 1 0 1 0 -25.1 0.2 -24.6 -25.2 03/30/2005 00:10:00 11 1 13 8.4 11.1 1 13.3 8.4 0.4 0 0.4 0.4 347 5 351 305 1 0 1 0 -25.2 0.2 -24.7 -25.4 03/30/2005 00:20:00 10.7 1 13.3 7.6 10.4 1 13 7.6 0.4 0 0.4 0.4 344 5 347 305 1 0 1 0 -25.2 0.2 -24.7 -25.4 03/30/2005 00:30:00 10.1 1 12.6 8 10.1 1 12.6 7.6 0.4 0 0.4 0.4 346 5 352 305 1 0 1 0 -25.2 0.2 -24.7 -25.4 03/30/2005 00:40:00 11 0.9 13.3 8.8 10.9 1 13.3 8.4 0.4 0 0.4 0.4 344 4 346 305 1 0 1 0 -25.2 0.1 -24.7 -25.4 03/30/2005 00:50:00 10.6 0.8 13 8.4 10.5 0.9 12.6 8.8 0.4 0 0.4 0.4 345 4 341 305 1 0 1 0 -25.2 0.1 -24.6 -25.4 03/30/2005 01:00:00 10.1 0.9 12.2 8 10.2 1 12.6 8 0.4 0 0.4 0.4 349 6 348 305 1 0 1 0 -25.2 0.2 -24.6 -25.2 03/30/2005 01:10:00 10.6 1 12.6 8 10.5 1 13 8 0.4 0 0.4 0.4 354 5 359 305 1 0 1 0 -25.1 0.1 -24.6 -25.2 03/30/2005 01:20:00 9.8 1.1 12.6 7.2 9.9 1.1 12.6 6.8 0.4 0 0.4 0.4 354 5 355 305 1 0 1 0 -25.1 0.1 -24.6 -25.2 03/30/2005 01:30:00 9.9 0.8 11.8 7.2 10.1 0.9 12.2 8 0.4 0 0.4 0.4 347 5 351 305 1 0 1 0 -25.2 0.1 -24.7 -25.4 03/30/2005 01:40:00 9.1 1.1 11.5 6.5 9.2 1.1 12.2 6.5 0.4 0 0.4 0.4 349 5 347 305 1 0 1 0 -25.2 0.1 -24.7 -25.4 03/30/2005 01:50:00 8.7 1 11.1 6.5 8.8 1.1 11.5 6.1 0.4 0 0.4 0.4 353 5 354 305 1 0 1 0 -25.2 0.1 -24.7 -25.2 03/30/2005 02:00:00 8.8 0.9 11.1 6.8 8.9 0.9 11.1 6.8 0.4 0 0.4 0.4 351 4 354 305 1 0 1 0 -25.2 0.1 -24.6 -25.2 03/30/2005 02:10:00 9.6 1 11.5 6.5 9.7 1.1 11.8 6.8 0.4 0 0.4 0.4 352 5 358 305 1 0 1 0 -25.3 0.1 -24.7 -25.4 03/30/2005 02:20:00 9.9 1 11.8 7.2 10 1 12.2 6.8 0.4 0 0.4 0.4 354 4 353 305 1 0 1 0 -25.3 0.1 -24.7 -25.4 03/30/2005 02:30:00 10 0.9 11.8 8 9.9 1 11.8 7.6 0.4 0 0.4 0.4 357 5 355 305 1 0 1 0 -25.3 0.1 -24.7 -25.6 03/30/2005 02:40:00 9.6 1 12.2 6.8 9.6 1 11.8 6.8 0.4 0 0.4 0.4 358 5 359 305 1 0 1 0 -25.3 0.1 -24.9 -25.6 03/30/2005 02:50:00 9.3 0.8 11.8 7.2 9.3 0.8 11.5 7.2 0.4 0 0.4 0.4 356 4 4 305 1 0 1 0 -25.3 0.1 -24.9 -25.4 03/30/2005 03:00:00 9.4 1 11.5 6.8 9.5 1 11.8 6.5 0.4 0 0.4 0.4 354 5 354 305 1 0 1 0 -25.2 0.1 -24.7 -25.4 03/30/2005 03:10:00 9.2 0.9 11.1 6.8 9.3 0.9 11.8 6.5 0.4 0 0.4 0.4 359 5 5 305 1 0 1 0 -25.2 0.1 -24.9 -25.4 03/30/2005 03:20:00 9.6 1.1 12.2 7.6 9.5 1.1 12.6 7.2 0.4 0 0.4 0.4 359 5 4 305 1 0 1 0 -25.2 0.1 -24.9 -25.2 03/30/2005 03:30:00 9.6 0.9 11.8 7.2 9.6 0.9 11.8 7.6 0.4 0 0.4 0.4 359 5 357 305 1 0 1 0 -25.2 0.1 -24.7 -25.4 03/30/2005 03:40:00 9.5 1 11.8 6.5 9.6 0.9 11.8 6.5 0.4 0 0.4 0.4 359 5 1 305 1 0 1 0 -25.2 0.1 -24.7 -25.4 03/30/2005 03:50:00 9.6 0.9 11.8 7.6 9.7 0.8 12.2 8 0.4 0 0.4 0.4 1 5 7 305 1 0 1 0 -25.2 0.1 -24.7 -25.4 03/30/2005 04:00:00 9.2 0.9 11.5 7.2 9.2 0.8 11.5 6.8 0.4 0 0.4 0.4 1 5 0 305 1 0 1 0 -25.1 0 -24.6 -25.2 03/30/2005 04:10:00 9 1 11.5 6.5 9.1 1 11.8 6.8 0.4 0 0.4 0.4 359 5 0 305 1 0 1 0 -25 0 -24.6 -25.2 03/30/2005 04:20:00 8.8 0.8 10.7 6.8 8.8 0.9 11.1 6.5 0.4 0 0.4 0.4 359 5 352 305 1 0 1 0 -25 0.1 -24.6 -25.2 03/30/2005 04:30:00 9.1 1 11.5 6.8 9.1 1 11.5 6.8 0.4 0 0.4 0.4 359 5 353 305 1 0 1 0 -25.1 0.1 -24.6 -25.2 03/30/2005 04:40:00 9.1 0.8 10.7 7.2 9.1 0.8 10.7 6.8 0.4 0 0.4 0.4 356 4 352 305 1 0 1 0 -25 0.1 -24.6 -25.2 03/30/2005 04:50:00 8.9 0.9 11.1 6.5 9 0.9 11.1 6.5 0.4 0 0.4 0.4 356 4 356 305 1 0 1 0 -25 0.1 -24.6 -25.2 03/30/2005 05:00:00 8.9 0.9 11.1 6.5 8.9 0.9 11.5 6.1 0.4 0 0.4 0.4 355 4 358 305 1 0 1 0 -25.1 0 -24.6 -25.2 03/30/2005 05:10:00 8.7 0.7 10.3 6.5 8.8 0.7 10.3 7.2 0.4 0 0.4 0.4 355 4 4 305 1 0 1 0 -25.1 0 -24.6 -25.2 03/30/2005 05:20:00 9.1 0.7 10.7 6.8 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 353 4 1 305 1 0 1 0 -25 0 -24.6 -25.1 03/30/2005 05:30:00 8.8 0.6 10.3 7.2 8.9 0.7 10.3 7.2 0.4 0 0.4 0.4 353 4 352 305 1 0 1 0 -25 0 -24.6 -25.1 03/30/2005 05:40:00 8.8 0.6 9.9 7.2 9 0.6 10.3 7.6 0.4 0 0.4 0.4 354 4 350 305 1 0 1 0 -25 0 -24.6 -25.1 03/30/2005 05:50:00 8.2 0.8 9.9 6.1 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 356 5 355 305 1 0 1 0 -24.9 0.1 -24.6 -25.1 03/30/2005 06:00:00 8.4 0.8 10.7 6.5 8.5 0.8 10.7 6.5 0.4 0 0.4 0.4 358 6 5 305 1 0 1 0 -24.8 0.1 -24.4 -25.1 03/30/2005 06:10:00 7.6 0.8 9.5 5.3 7.6 0.9 9.9 5.3 0.4 0 0.4 0.4 2 6 359 305 1 0 1 0 -24.9 0.1 -24.4 -25.1 03/30/2005 06:20:00 7.8 1.1 9.9 4.9 7.8 1.1 10.3 4.9 0.4 0 0.4 0.4 7 6 16 305 1 0 1 0 -25 0.1 -24.4 -25.2 03/30/2005 06:30:00 8.3 0.7 10.3 6.5 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 9 4 9 305 1 0 1 0 -25 0.1 -24.6 -25.2 03/30/2005 06:40:00 8.4 0.7 9.9 6.5 8.4 0.7 9.9 6.8 0.4 0 0.4 0.4 8 4 8 305 1 0 1 0 -25.1 0 -24.6 -25.2 03/30/2005 06:50:00 8 0.8 9.9 6.1 8 0.8 9.9 6.1 0.4 0 0.4 0.4 8 4 11 305 1 0 1 0 -25 0 -24.6 -25.1 03/30/2005 07:00:00 8.4 0.9 10.3 6.5 8.4 0.9 10.7 6.1 0.4 0 0.4 0.4 8 4 16 305 1 0 1 0 -25 0.1 -24.6 -25.2 03/30/2005 07:10:00 8.7 0.6 9.9 6.8 8.7 0.7 10.3 6.8 0.4 0 0.4 0.4 9 5 6 305 1 0 1 0 -25 0 -24.6 -25.1 03/30/2005 07:20:00 9.1 0.7 10.7 7.2 9.2 0.7 11.5 7.2 0.4 0 0.4 0.4 6 4 8 305 1 0 1 0 -24.9 0.1 -24.6 -25.1 03/30/2005 07:30:00 8.9 1 11.1 6.5 8.9 1 10.7 6.1 0.4 0 0.4 0.4 4 5 1 305 1 0 1 0 -24.9 0.1 -24.4 -25.1 03/30/2005 07:40:00 9.6 0.9 11.8 6.5 9.6 1 11.5 6.8 0.4 0 0.4 0.4 2 4 3 305 1 0 1 0 -24.8 0 -24.2 -24.9 03/30/2005 07:50:00 8.3 0.8 10.7 5.7 8.4 0.9 11.1 6.1 0.4 0 0.4 0.4 8 5 5 305 1 0 1 0 -24.7 0.1 -24.2 -24.9 03/30/2005 08:00:00 9.2 0.7 11.1 7.2 9.2 0.8 11.1 7.2 0.4 0 0.4 0.4 6 5 2 305 1 0 1 0 -24.7 0.1 -24.2 -24.7 03/30/2005 08:10:00 9.7 1 11.8 7.2 9.8 1 11.8 6.8 0.4 0 0.4 0.4 6 4 9 305 1 0 1 0 -24.6 0.2 -24.1 -24.7 03/30/2005 08:20:00 9.6 0.7 11.5 8 9.6 0.8 11.5 7.6 0.4 0 0.4 0.4 4 4 359 305 1 0 1 0 -24.5 0.2 -23.9 -24.7 03/30/2005 08:30:00 8.3 1 10.7 6.1 8.4 1 11.1 6.1 0.4 0 0.4 0.4 4 5 3 305 1 0 1 0 -24.4 0.2 -23.9 -24.6 03/30/2005 08:40:00 9.2 0.8 11.1 6.8 9.2 0.9 11.8 7.2 0.4 0 0.4 0.4 7 5 4 305 1 0 1 0 -24.4 0.2 -23.9 -24.6 03/30/2005 08:50:00 9.7 1 11.8 6.5 9.7 1 11.8 6.8 0.4 0 0.4 0.4 7 5 10 305 1 0 1 0 -24.4 0 -24.1 -24.6 03/30/2005 09:00:00 9.4 0.7 11.5 7.6 9.4 0.7 11.5 7.6 0.4 0 0.4 0.4 8 5 9 305 1 0 1 0 -24.4 0.1 -23.9 -24.6 03/30/2005 09:10:00 10.1 0.8 11.8 7.6 10.1 0.8 12.2 8 0.4 0 0.4 0.4 6 3 7 305 1 0 1 0 -24.2 0.1 -23.7 -24.4 03/30/2005 09:20:00 8.9 1 11.5 6.1 8.9 1 11.5 6.1 0.4 0 0.4 0.4 5 5 1 305 1 0 2 0 -24 0.1 -23.4 -24.2 03/30/2005 09:30:00 9.1 1.1 11.5 6.8 9.2 1.1 11.8 6.8 0.4 0 0.4 0.4 5 5 356 305 2 0 1 0 -23.9 0.1 -23.4 -23.9 03/30/2005 09:40:00 9.2 0.8 11.5 6.8 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 4 5 10 305 1 0 1 0 -23.8 0 -23.4 -23.9 03/30/2005 09:50:00 8.5 0.9 10.7 6.1 8.6 1 11.1 6.5 0.4 0 0.4 0.4 3 5 3 305 1 0 1 0 -23.6 0.1 -23.4 -23.9 03/30/2005 10:00:00 10.1 0.8 11.8 8 10.2 0.9 11.8 7.6 0.4 0 0.4 0.4 6 4 9 305 1 0 1 0 -23.6 0 -23.4 -23.9 03/30/2005 10:10:00 9.3 1 11.8 6.5 9.3 1 11.8 6.8 0.4 0 0.4 0.4 5 4 5 305 1 0 1 0 -23.5 0 -23.4 -23.7 03/30/2005 10:20:00 10.2 0.9 11.8 7.6 10.1 0.9 12.2 8 0.4 0 0.4 0.4 5 5 5 305 1 0 1 0 -23.5 0 -23 -23.6 03/30/2005 10:30:00 10.1 1.1 12.2 7.2 10.1 1.1 11.8 6.8 0.4 0 0.4 0.4 5 4 9 305 1 0 1 0 -23.4 0 -23 -23.6 03/30/2005 10:40:00 9.8 0.8 11.5 7.2 9.8 0.9 11.8 7.2 0.4 0 0.4 0.4 1 4 3 305 2 0 1 0 -23.2 0 -22.9 -23.4 03/30/2005 10:50:00 9.1 0.8 11.5 6.8 9.2 0.8 11.8 7.2 0.4 0 0.4 0.4 1 4 2 305 1 0 1 0 -23.1 0 -22.9 -23.2 03/30/2005 11:00:00 8.8 0.8 10.7 6.5 8.9 0.8 10.7 6.5 0.4 0 0.4 0.4 3 6 2 305 1 0 1 0 -23.1 0 -22.9 -23.2 03/30/2005 11:10:00 8.9 0.8 11.1 6.1 9.1 0.9 11.1 6.1 0.4 0 0.4 0.4 3 5 4 305 1 0 1 0 -23 0 -22.9 -23.2 03/30/2005 11:20:00 9.2 1 11.5 6.1 9.4 0.8 11.1 6.8 0.4 0 0.4 0.4 3 5 7 305 1 0 1 0 -22.9 0 -22.7 -23 03/30/2005 11:30:00 9.1 1 11.1 6.5 9.1 1 11.5 6.5 0.4 0 0.4 0.4 1 5 2 305 1 0 1 0 -22.8 0 -22.5 -23 03/30/2005 11:40:00 9.5 0.9 11.5 7.2 9.5 1 11.5 7.2 0.4 0 0.4 0.4 1 4 6 305 1 0 1 0 -22.8 0 -22.5 -22.9 03/30/2005 11:50:00 9.2 0.9 11.1 6.8 9.2 0.9 11.5 6.8 0.4 0 0.4 0.4 4 6 359 305 1 0 1 0 -22.7 0 -22.5 -22.9 03/30/2005 12:00:00 9.4 0.8 11.5 7.2 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 2 5 4 305 1 0 1 0 -22.7 0 -22.5 -22.9 03/30/2005 12:10:00 9.6 0.8 11.5 7.2 9.6 0.9 11.8 6.8 0.4 0 0.4 0.4 3 5 357 305 1 0 1 0 -22.5 0 -22.4 -22.7 03/30/2005 12:20:00 8.9 0.8 11.1 6.8 9 0.9 11.5 6.5 0.4 0 0.4 0.4 3 6 359 305 1 0 1 0 -22.4 0 -22.2 -22.5 03/30/2005 12:30:00 9.2 1 11.1 6.5 9.2 1 11.5 6.5 0.4 0 0.4 0.4 1 5 3 305 1 0 1 0 -22.3 0 -22.2 -22.5 03/30/2005 12:40:00 9.4 1 11.5 6.5 9.5 1 11.8 6.8 0.4 0 0.4 0.4 0 5 355 305 1 0 1 0 -22.3 0 -22 -22.5 03/30/2005 12:50:00 9.1 1 11.5 6.8 9.2 0.9 11.5 7.2 0.4 0 0.4 0.4 1 5 4 305 1 0 1 0 -22.2 0 -22 -22.4 03/30/2005 13:00:00 9.3 0.9 11.1 6.5 9.4 0.9 11.5 7.2 0.4 0 0.4 0.4 3 5 11 305 1 0 1 0 -22.1 0 -21.8 -22.4 03/30/2005 13:10:00 9.5 1.1 11.8 6.5 9.5 1.2 12.6 6.5 0.4 0 0.4 0.4 0 5 0 305 1 0 1 0 -22 0.1 -21.8 -22.2 03/30/2005 13:20:00 9.5 1 11.5 6.8 9.6 1 11.8 6.5 0.4 0 0.4 0.4 2 5 0 305 1 0 1 0 -22 0 -21.8 -22.2 03/30/2005 13:30:00 9.1 0.8 11.5 7.2 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 4 5 3 305 1 0 1 0 -21.9 0 -21.8 -22 03/30/2005 13:40:00 8.4 0.8 10.3 6.1 8.5 0.8 10.7 6.5 0.4 0 0.4 0.4 1 5 357 305 1 0 1 0 -21.8 0 -21.7 -21.8 03/30/2005 13:50:00 8 0.8 10.7 6.1 8 0.8 10.3 5.7 0.4 0 0.4 0.4 359 7 4 305 1 0 1 0 -21.5 0.1 -21.3 -21.8 03/30/2005 14:00:00 8.7 0.9 10.7 6.1 8.8 0.9 10.7 6.1 0.4 0 0.4 0.4 2 6 2 305 1 0 1 0 -21.6 0.1 -21.3 -21.8 03/30/2005 14:10:00 9.3 0.8 11.1 6.1 9.4 0.8 11.5 6.5 0.4 0 0.4 0.4 6 5 1 305 1 0 1 0 -21.5 0 -21.3 -21.7 03/30/2005 14:20:00 8.5 0.8 10.3 6.5 8.5 0.8 10.3 6.1 0.4 0 0.4 0.4 3 7 9 305 1 0 1 0 -21.4 0.1 -21.3 -21.7 03/30/2005 14:30:00 8.6 1.1 11.1 5.7 8.5 1.2 11.1 5.7 0.4 0 0.4 0.4 5 6 7 305 1 0 1 0 -21.3 0 -21 -21.5 03/30/2005 14:40:00 8.7 0.9 10.7 5.7 8.7 0.9 10.7 5.7 0.4 0 0.4 0.4 4 6 0 305 1 0 1 0 -21.3 0 -21.1 -21.5 03/30/2005 14:50:00 8.6 0.8 11.1 6.5 8.7 0.9 11.1 6.1 0.4 0 0.4 0.4 4 6 8 305 1 0 1 0 -21.1 0.1 -20.8 -21.3 03/30/2005 15:00:00 9 0.9 10.7 6.5 9 1 11.1 6.5 0.4 0 0.4 0.4 4 5 7 305 1 0 1 0 -21.2 0 -20.8 -21.3 03/30/2005 15:10:00 8.7 0.8 10.7 6.5 8.8 0.8 10.7 6.5 0.4 0 0.4 0.4 3 5 1 305 1 0 1 0 -21 0 -20.8 -21.3 03/30/2005 15:20:00 7.8 1.2 10.7 4.9 7.9 1.2 11.1 5.3 0.4 0 0.4 0.4 359 6 1 305 1 0 1 0 -20.8 0.1 -20.6 -21.3 03/30/2005 15:30:00 7.9 0.8 9.9 5.7 7.9 0.8 9.9 5.3 0.4 0 0.4 0.4 0 6 353 305 1 0 1 0 -20.7 0 -20.4 -21 03/30/2005 15:40:00 8.7 0.9 10.3 6.1 8.7 1 10.7 6.1 0.4 0 0.4 0.4 357 5 1 305 1 0 1 0 -20.7 0 -20.4 -21 03/30/2005 15:50:00 7.8 1 10.7 5.7 7.9 1 10.7 5.3 0.4 0 0.4 0.4 359 6 12 305 1 0 1 0 -20.7 0 -20.4 -21 03/30/2005 16:00:00 8.3 0.7 9.9 6.5 8.3 0.7 9.9 6.1 0.4 0 0.4 0.4 5 5 8 305 1 0 1 0 -20.6 0 -20.4 -20.8 03/30/2005 16:10:00 8.4 0.8 10.3 6.5 8.5 0.8 10.7 6.5 0.4 0 0.4 0.4 5 6 359 305 1 0 1 0 -20.6 0 -20.4 -20.8 03/30/2005 16:20:00 8.8 0.8 10.3 6.1 8.8 0.8 10.7 6.5 0.4 0 0.4 0.4 3 5 7 305 1 0 1 0 -20.6 0.1 -20.2 -20.8 03/30/2005 16:30:00 9.1 0.7 10.7 6.8 9 0.7 10.7 6.8 0.4 0 0.4 0.4 3 5 3 305 1 0 1 0 -20.5 0 -20.2 -20.8 03/30/2005 16:40:00 8.6 0.8 10.7 6.5 8.7 0.9 11.1 6.5 0.4 0 0.4 0.4 0 5 0 305 1 0 1 0 -20.4 0 -20.2 -20.8 03/30/2005 16:50:00 9 0.7 10.7 6.8 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 7 5 11 305 1 0 1 0 -20.5 0.1 -20.1 -20.8 03/30/2005 17:00:00 9 0.9 10.7 6.5 9.1 0.9 11.1 6.5 0.4 0 0.4 0.4 4 5 4 305 1 0 1 0 -20.5 0 -20.1 -20.6 03/30/2005 17:10:00 8.6 0.8 10.3 6.5 8.7 0.8 10.3 6.8 0.4 0 0.4 0.4 0 5 359 305 1 0 1 0 -20.4 0 -20.1 -20.6 03/30/2005 17:20:00 8.8 1 11.5 6.5 8.9 1 11.1 6.8 0.4 0 0.4 0.4 357 6 350 305 1 0 1 0 -20.2 0 -20.1 -20.4 03/30/2005 17:30:00 7.9 1 9.9 5.3 8 1 10.3 4.9 0.4 0 0.4 0.4 0 7 6 305 1 0 1 0 -20.1 0 -19.9 -20.1 03/30/2005 17:40:00 8.5 0.9 10.3 6.1 8.4 0.9 10.7 5.7 0.4 0 0.4 0.4 0 6 2 305 1 0 1 0 -20.1 0 -19.9 -20.2 03/30/2005 17:50:00 8.4 0.8 10.3 6.1 8.4 0.9 10.7 5.7 0.4 0 0.4 0.4 357 5 356 305 1 0 1 0 -20.2 0 -19.9 -20.1 03/30/2005 18:00:00 7.7 1 9.9 5.3 7.7 1 9.9 4.9 0.4 0 0.4 0.4 357 7 0 305 1 0 1 0 -19.9 0.1 -19.5 -20.1 03/30/2005 18:10:00 7.4 0.9 9.5 4.6 7.5 0.9 9.9 4.9 0.4 0 0.4 0.4 2 7 8 305 1 0 1 0 -19.9 0 -19.5 -20.1 03/30/2005 18:20:00 8.4 0.8 10.3 6.5 8.4 0.8 10.3 6.5 0.4 0 0.4 0.4 7 4 6 305 1 0 1 0 -20 0 -19.9 -20.1 03/30/2005 18:30:00 8.2 1 10.3 5.7 8.3 1.1 10.7 5.7 0.4 0 0.4 0.4 1 6 10 305 1 0 1 0 -19.9 0 -19.5 -20.1 03/30/2005 18:40:00 8.7 0.9 10.3 5.7 8.7 0.9 10.3 6.5 0.4 0 0.4 0.4 7 5 357 305 1 0 1 0 -19.9 0.1 -19.5 -20.1 03/30/2005 18:50:00 7.9 0.7 9.5 6.1 7.9 0.8 9.9 6.1 0.4 0 0.4 0.4 10 6 11 305 1 0 1 0 -19.9 0 -19.7 -20.1 03/30/2005 19:00:00 8 0.8 9.5 6.1 7.9 0.8 9.9 5.3 0.4 0 0.4 0.4 8 5 7 305 1 0 1 0 -19.9 0 -19.7 -20.1 03/30/2005 19:10:00 8.8 0.6 10.3 7.2 8.8 0.7 10.3 6.1 0.4 0 0.4 0.4 7 5 15 305 1 0 1 0 -20 0 -19.9 -20.1 03/30/2005 19:20:00 8.6 0.8 10.7 6.5 8.7 0.8 10.7 6.5 0.4 0 0.4 0.4 5 5 8 305 1 0 1 0 -19.9 0 -19.5 -20.1 03/30/2005 19:30:00 8.3 0.8 10.3 6.1 8.4 0.9 10.7 6.1 0.4 0 0.4 0.4 2 5 0 305 1 0 1 0 -19.8 0 -19.5 -20.1 03/30/2005 19:40:00 8.2 0.9 10.3 5.7 8.3 1 10.7 6.1 0.4 0 0.4 0.4 8 6 3 305 1 0 1 0 -20 0 -19.7 -20.1 03/30/2005 19:50:00 8.5 0.8 9.9 6.1 8.5 0.8 9.9 6.5 0.4 0 0.4 0.4 12 5 7 305 1 0 1 0 -20.2 0 -19.9 -20.2 03/30/2005 20:00:00 8.9 0.6 11.1 6.8 8.8 0.7 10.3 7.2 0.4 0 0.4 0.4 12 5 18 305 1 0 1 0 -20.2 0 -20.1 -20.1 03/30/2005 20:10:00 8.8 1 11.1 6.5 8.8 1 11.1 6.8 0.4 0 0.4 0.4 12 6 2 305 1 0 1 0 -20.1 0 -19.9 -20.1 03/30/2005 20:20:00 8.7 0.9 10.3 6.1 8.7 0.8 10.7 6.5 0.4 0 0.4 0.4 18 5 22 305 1 0 1 0 -20.2 0 -20.1 -20.2 03/30/2005 20:30:00 8.4 1 10.3 5.7 8.3 0.9 10.3 6.1 0.4 0 0.4 0.4 18 5 21 305 1 0 1 0 -20.3 0 -20.1 -20.6 03/30/2005 20:40:00 8.8 0.8 10.7 6.5 8.8 0.8 10.7 6.8 0.4 0 0.4 0.4 17 6 15 305 1 0 1 0 -20.4 0 -20.1 -20.6 03/30/2005 20:50:00 9.3 0.7 11.1 7.2 9.3 0.8 11.1 6.8 0.4 0 0.4 0.4 12 3 15 305 1 0 1 0 -20.6 0 -20.4 -20.8 03/30/2005 21:00:00 9.5 0.8 11.5 7.6 9.5 0.8 11.5 7.6 0.4 0 0.4 0.4 9 5 8 305 1 0 1 0 -20.6 0 -20.4 -20.8 03/30/2005 21:10:00 8.7 1 11.1 6.1 8.7 1 10.7 6.1 0.4 0 0.4 0.4 12 6 7 305 1 0 1 0 -20.6 0 -20.4 -20.8 03/30/2005 21:20:00 9.1 0.7 10.7 6.8 9 0.7 10.7 6.8 0.4 0 0.4 0.4 20 4 22 305 1 0 1 0 -20.7 0 -20.6 -20.8 03/30/2005 21:30:00 9 0.6 10.7 7.2 8.9 0.6 11.1 7.2 0.4 0 0.4 0.4 19 3 16 305 1 0 1 0 -20.8 0 -20.8 -21 03/30/2005 21:40:00 8.6 0.7 10.7 6.8 8.3 0.8 9.9 5.7 0.4 0 0.4 0.4 18 4 16 305 1 0 1 0 -20.8 0 -20.2 -21 03/30/2005 21:50:00 8.8 0.6 10.3 7.2 8.6 0.7 9.9 6.8 0.4 0 0.4 0.4 18 5 10 305 1 0 1 0 -20.8 0 -20.8 -21 03/30/2005 22:00:00 8.9 0.8 10.7 6.8 8.8 0.9 11.1 6.5 0.4 0 0.4 0.4 20 4 19 305 1 0 1 0 -20.9 0 -20.8 -21.1 03/30/2005 22:10:00 9.4 0.8 10.7 7.2 9.3 0.9 11.1 6.5 0.4 0 0.4 0.4 20 5 22 305 1 0 1 0 -21 0 -20.8 -21.3 03/30/2005 22:20:00 9.3 0.8 10.7 6.8 9.3 0.9 11.1 6.5 0.4 0 0.4 0.4 20 4 33 305 1 0 1 0 -21 0 -20.6 -21.3 03/30/2005 22:30:00 9.2 0.6 10.7 7.2 9 0.7 10.7 6.8 0.4 0 0.4 0.4 17 4 17 305 1 0 1 0 -21.1 0 -21 -21.3 03/30/2005 22:40:00 8.7 0.8 10.3 6.5 8.5 0.9 10.3 6.5 0.4 0 0.4 0.4 14 4 15 305 1 0 1 0 -21.1 0 -21 -21.3 03/30/2005 22:50:00 8.1 0.7 9.9 6.1 8 0.8 9.9 6.1 0.4 0 0.4 0.4 9 4 12 305 1 0 1 0 -21.2 0 -21 -21.3 03/30/2005 23:00:00 6.9 0.6 8.4 5.3 6.9 0.6 8.8 5.3 0.4 0 0.4 0.4 13 6 6 305 1 0 1 0 -21.2 0 -21.1 -21.3 03/30/2005 23:10:00 6.7 0.8 8 4.9 6.7 0.8 8.4 4.6 0.4 0 0.4 0.4 12 5 8 305 1 0 1 0 -21.3 0 -21 -21.3 03/30/2005 23:20:00 6.5 0.8 8.4 4.6 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 14 6 19 305 1 0 1 0 -21.3 0 -20.8 -21.3 03/30/2005 23:30:00 6.6 0.5 8 4.9 6.6 0.5 8.4 5.3 0.4 0 0.4 0.4 13 5 11 305 1 0 1 0 -21.3 0 -21.1 -21.3 03/30/2005 23:40:00 6.2 0.6 7.2 4.6 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 19 4 16 305 2 0 1 0 -21.3 0 -21.1 -21.5 03/30/2005 23:50:00 6 0.6 7.2 4.6 5.9 0.6 7.2 4.6 0.4 0 0.4 0.4 12 7 17 305 2 0 2 0 -21.3 0 -21.3 -21.5 03/31/2005 00:00:00 6.8 0.5 8.4 5.3 6.7 0.6 8 5.3 0.4 0 0.4 0.4 11 3 13 305 2 0 1 0 -21.3 0 -21 -21.5 03/31/2005 00:10:00 6.6 0.6 8 4.9 6.6 0.6 8 4.9 0.4 0 0.4 0.4 18 5 20 305 2 0 2 0 -21.3 0 -21.3 -21.5 03/31/2005 00:20:00 6.5 0.7 8 4.9 6.5 0.7 8 4.6 0.4 0 0.4 0.4 21 4 20 305 2 0 2 0 -21.3 0 -21.3 -21.5 03/31/2005 00:30:00 6.2 0.7 7.6 4.2 6.1 0.7 8 4.2 0.4 0 0.4 0.4 20 5 20 305 2 0 2 0 -21.4 0 -21.3 -21.7 03/31/2005 00:40:00 6 0.7 7.6 4.2 5.9 0.7 7.6 4.2 0.4 0 0.4 0.4 22 6 16 305 2 0 2 0 -21.4 0.1 -21.3 -21.7 03/31/2005 00:50:00 5.8 0.5 6.8 4.6 5.7 0.6 6.8 4.2 0.4 0 0.4 0.4 22 5 22 305 2 0 2 0 -21.6 0 -21.3 -21.7 03/31/2005 01:00:00 6.2 0.5 7.6 4.9 6.1 0.6 7.2 4.6 0.4 0 0.4 0.4 20 3 23 305 2 0 2 0 -21.7 0 -21.5 -21.8 03/31/2005 01:10:00 5.8 0.4 6.8 4.6 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 20 3 21 305 2 0 2 0 -21.7 0 -21.5 -21.8 03/31/2005 01:20:00 5.5 0.4 6.1 4.6 5.5 0.4 6.1 4.2 0.4 0 0.4 0.4 22 3 21 305 2 0 2 0 -21.7 0 -21.5 -21.8 03/31/2005 01:30:00 5.7 0.5 6.8 4.6 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 25 5 21 305 2 0 2 0 -21.8 0 -21.7 -22 03/31/2005 01:40:00 6.2 0.4 7.2 4.9 6.1 0.5 7.2 4.9 0.4 0 0.4 0.4 30 4 27 305 2 0 2 0 -21.8 0 -21.7 -21.8 03/31/2005 01:50:00 5.6 0.4 6.5 4.6 5.5 0.4 6.8 4.6 0.4 0 0.4 0.4 30 3 35 305 2 0 2 0 -21.8 0 -21.7 -21.8 03/31/2005 02:00:00 5.2 0.5 6.1 4.2 5 0.4 6.1 3.8 0.4 0 0.4 0.4 32 4 31 305 2 0 2 0 -21.8 0 -21.7 -22 03/31/2005 02:10:00 5.1 0.4 6.1 4.2 4.9 0.4 6.1 3.8 0.4 0 0.4 0.4 27 5 31 305 2 0 2 0 -21.8 0 -21.7 -21.8 03/31/2005 02:20:00 5.3 0.4 6.1 4.2 5.2 0.5 6.1 3.8 0.4 0 0.4 0.4 26 4 26 305 2 0 2 0 -21.9 0 -21.8 -22 03/31/2005 02:30:00 5.3 0.3 6.1 4.2 5.2 0.4 6.1 3.8 0.4 0 0.4 0.4 20 4 21 305 2 0 2 0 -22 0 -21.8 -22 03/31/2005 02:40:00 4.8 0.4 5.7 3.8 4.8 0.5 5.7 3.4 0.4 0 0.4 0.4 18 3 18 305 2 0 2 0 -22 0 -21.5 -22.2 03/31/2005 02:50:00 4.4 0.5 5.3 3.4 4.4 0.5 5.3 3 0.4 0 0.4 0.4 19 2 18 305 2 0 2 0 -22.1 0 -21.8 -22.2 03/31/2005 03:00:00 4.1 0.3 4.9 3 4 0.3 4.9 3 0.4 0 0.4 0.4 23 2 25 305 2 0 2 0 -22.1 0 -21.8 -22.2 03/31/2005 03:10:00 4.5 0.5 5.7 3.4 4.3 0.5 5.7 3.4 0.4 0 0.4 0.4 30 4 27 305 2 0 2 0 -22.1 0 -21.8 -22.2 03/31/2005 03:20:00 5.5 0.4 6.5 4.2 5.3 0.4 6.5 4.2 0.4 0 0.4 0.4 31 3 33 305 2 0 2 0 -22 0 -21.8 -22.2 03/31/2005 03:30:00 4.9 0.5 6.1 3.4 4.7 0.5 6.1 3.4 0.4 0 0.4 0.4 34 4 32 305 2 0 2 0 -22 0 -21.7 -22.2 03/31/2005 03:40:00 4.2 0.4 5.3 3 4 0.5 4.9 3 0.4 0 0.4 0.4 39 4 37 305 2 0 2 0 -22 0 -21.8 -22.2 03/31/2005 03:50:00 4.2 0.4 5.3 3 4 0.5 5.3 3 0.4 0 0.4 0.4 37 5 32 305 2 0 2 0 -22.1 0 -21.8 -22.2 03/31/2005 04:00:00 5.2 0.6 6.5 3.8 5 0.7 6.1 3.8 0.4 0 0.4 0.4 30 6 22 305 2 0 2 0 -22.1 0 -21.8 -22.2 03/31/2005 04:10:00 5.3 0.3 6.1 4.2 5.2 0.4 6.1 4.2 0.4 0 0.4 0.4 21 2 25 305 2 0 2 0 -22 0 -21.7 -22.2 03/31/2005 04:20:00 5.3 0.4 6.1 4.6 5.2 0.4 6.1 4.2 0.4 0 0.4 0.4 23 3 22 305 2 0 2 0 -22.1 0 -21.8 -22.2 03/31/2005 04:30:00 5.3 0.4 6.5 4.2 5.2 0.5 6.5 4.2 0.4 0 0.4 0.4 24 3 27 305 2 0 2 0 -22.1 0 -21.8 -22.2 03/31/2005 04:40:00 5.4 0.4 6.5 4.2 5.2 0.5 6.5 4.2 0.4 0 0.4 0.4 26 3 25 305 2 0 2 0 -22.1 0 -21.8 -22.2 03/31/2005 04:50:00 5.3 0.5 6.5 3.8 5.2 0.5 6.5 3.8 0.4 0 0.4 0.4 34 6 33 305 2 0 2 0 -22 0.1 -21.8 -22.2 03/31/2005 05:00:00 5.4 0.4 6.5 3.8 5.2 0.4 6.5 3.8 0.4 0 0.4 0.4 43 4 41 305 2 0 2 0 -22 0 -21.8 -22.2 03/31/2005 05:10:00 5.7 0.3 6.5 4.9 5.6 0.3 6.5 4.6 0.4 0 0.4 0.4 36 5 44 305 2 0 2 0 -22 0 -21.8 -22.2 03/31/2005 05:20:00 5 0.4 5.7 3.8 4.8 0.4 6.1 3.8 0.4 0 0.4 0.4 36 4 35 305 2 0 2 0 -22.1 0 -21.8 -22.2 03/31/2005 05:30:00 4.8 0.4 5.7 3.8 4.6 0.4 5.7 3.4 0.4 0 0.4 0.4 40 4 45 305 2 0 2 0 -22.1 0 -22 -22.4 03/31/2005 05:40:00 4.9 0.3 5.7 4.2 4.8 0.3 5.7 3.8 0.4 0 0.4 0.4 46 5 43 305 2 0 2 0 -22.1 0 -21.8 -22.2 03/31/2005 05:50:00 4.8 0.4 5.7 3.8 4.7 0.4 5.7 3.8 0.4 0 0.4 0.4 45 3 50 305 2 0 2 0 -22.1 0 -21.8 -22.4 03/31/2005 06:00:00 4.7 0.4 5.3 3.4 4.6 0.4 5.7 3.4 0.4 0 0.4 0.4 43 3 46 305 2 0 2 0 -22.1 0 -21.8 -22.4 03/31/2005 06:10:00 4.1 0.3 4.9 3.4 4.1 0.4 4.9 3 0.4 0 0.4 0.4 44 3 46 305 2 0 2 0 -22.2 0.1 -21.7 -22.4 03/31/2005 06:20:00 4.2 0.3 4.9 3.4 4.1 0.3 4.9 3.4 0.4 0 0.4 0.4 46 3 46 305 2 0 2 0 -22.2 0 -21.8 -22.4 03/31/2005 06:30:00 4 0.4 4.9 3.4 3.9 0.3 4.6 3 0.4 0 0.4 0.4 44 3 46 305 2 0 2 0 -22.2 0 -21.8 -22.4 03/31/2005 06:40:00 4.2 0.4 4.9 3 4.1 0.4 4.9 3 0.4 0 0.4 0.4 43 4 45 305 2 0 2 0 -22.3 0 -21.8 -22.4 03/31/2005 06:50:00 4.4 0.3 5.3 3.8 4.3 0.4 4.9 3.4 0.4 0 0.4 0.4 43 3 41 305 2 0 2 0 -22.2 0 -21.8 -22.4 03/31/2005 07:00:00 3.9 0.3 4.6 3 3.8 0.3 4.6 2.6 0.4 0 0.4 0.4 43 4 45 305 2 0 2 0 -22.2 0.1 -21.8 -22.4 03/31/2005 07:10:00 3.6 0.4 4.2 2.6 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 45 4 41 305 2 0 2 0 -22.2 0 -22 -22.4 03/31/2005 07:20:00 4.1 0.3 4.6 3.4 4 0.3 4.6 3 0.4 0 0.4 0.4 48 3 48 305 2 0 2 0 -22.3 0 -22 -22.5 03/31/2005 07:30:00 3.8 0.3 4.6 3 3.6 0.4 4.6 2.6 0.4 0 0.4 0.4 46 4 43 305 2 0 2 0 -22.3 0 -21.8 -22.5 03/31/2005 07:40:00 3.8 0.4 4.9 2.6 3.7 0.4 4.6 2.6 0.4 0 0.4 0.4 46 3 49 305 2 0 2 0 -22.3 0 -22.2 -22.4 03/31/2005 07:50:00 2.9 0.3 3.8 2.3 2.8 0.3 3.4 2.3 0.4 0 0.4 0.4 37 6 35 305 2 0 2 0 -22.2 0 -22 -22.4 03/31/2005 08:00:00 3.1 0.5 4.2 2.3 2.9 0.5 3.8 1.9 0.4 0 0.4 0.4 36 4 44 305 2 0 2 0 -22.2 0 -21.7 -22.4 03/31/2005 08:10:00 4 0.3 4.9 3 3.9 0.3 4.9 3 0.4 0 0.4 0.4 38 4 32 305 2 0 2 0 -22.3 0 -22 -22.4 03/31/2005 08:20:00 3.9 0.4 4.6 3 3.8 0.3 4.6 3 0.4 0 0.4 0.4 44 5 45 305 2 0 2 0 -22.2 0 -22 -22.4 03/31/2005 08:30:00 3.9 0.4 4.9 3 3.8 0.4 4.9 2.6 0.4 0 0.4 0.4 39 5 48 305 3 0 2 0 -22.1 0 -21.8 -22.2 03/31/2005 08:40:00 4.1 0.4 5.3 3 4 0.5 4.9 2.6 0.4 0 0.4 0.4 35 5 22 305 3 0 2 0 -22 0 -21.8 -22.2 03/31/2005 08:50:00 4.6 0.6 5.7 3 4.4 0.7 5.7 3 0.4 0 0.4 0.4 24 5 21 305 3 0 3 0 -22 0 -21.8 -22.2 03/31/2005 09:00:00 5 0.3 5.7 4.2 4.9 0.4 5.7 3.8 0.4 0 0.4 0.4 25 3 27 305 3 0 3 0 -21.9 0 -21.8 -22 03/31/2005 09:10:00 4.4 0.4 5.3 3.4 4.3 0.5 5.3 3 0.4 0 0.4 0.4 27 4 28 305 3 0 3 0 -21.7 0 -21.5 -21.8 03/31/2005 09:20:00 4.2 0.4 5.3 3.4 4.1 0.4 5.3 3 0.4 0 0.4 0.4 35 6 29 305 3 0 3 0 -21.7 0 -21.5 -21.8 03/31/2005 09:30:00 4.8 0.4 5.3 3.8 4.7 0.4 5.3 3.4 0.4 0 0.4 0.4 29 3 32 305 3 0 3 0 -21.5 0 -21.3 -21.8 03/31/2005 09:40:00 4.7 0.5 5.7 3.4 4.6 0.5 5.7 3.8 0.4 0 0.4 0.4 39 5 32 305 3 0 4 0 -21.3 0 -21.3 -21.7 03/31/2005 09:50:00 4.4 0.5 5.7 3 4.3 0.5 5.3 3 0.4 0 0.4 0.4 42 6 46 305 4 0 4 0 -21.2 0 -21 -21.3 03/31/2005 10:00:00 5.3 0.4 6.5 4.2 5.2 0.5 6.5 4.2 0.4 0 0.4 0.4 32 7 33 305 3 0 4 0 -21.1 0 -21 -21.3 03/31/2005 10:10:00 5.5 0.5 6.5 4.2 5.4 0.5 6.5 3.8 0.4 0 0.4 0.4 29 5 23 305 3 0 3 0 -21 0 -20.8 -21.3 03/31/2005 10:20:00 5.8 0.6 6.8 4.2 5.7 0.6 7.2 3.8 0.4 0 0.4 0.4 33 6 42 305 3 0 3 0 -21 0 -20.8 -21.1 03/31/2005 10:30:00 6.1 0.5 7.2 4.6 6 0.6 7.2 4.6 0.4 0 0.4 0.4 33 5 38 305 3 0 3 0 -20.9 0 -20.8 -21.1 03/31/2005 10:40:00 5.8 0.4 6.8 4.6 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 30 3 27 305 3 0 2 0 -20.8 0 -20.6 -21 03/31/2005 10:50:00 5.8 0.3 6.5 4.9 5.6 0.4 6.5 4.6 0.4 0 0.4 0.4 28 3 28 305 2 0 2 0 -20.7 0 -20.6 -21 03/31/2005 11:00:00 5.4 0.4 6.1 4.2 5.3 0.4 6.5 4.2 0.4 0 0.4 0.4 32 4 25 305 2 0 2 0 -20.7 0 -20.4 -20.8 03/31/2005 11:10:00 5.3 0.4 6.5 4.2 5.1 0.4 6.5 4.2 0.4 0 0.4 0.4 32 5 31 305 2 0 2 0 -20.6 0 -20.4 -20.8 03/31/2005 11:20:00 5.1 0.4 6.1 3.8 5 0.5 6.5 3.4 0.4 0 0.4 0.4 30 9 22 305 2 0 2 0 -20.5 0.1 -20.1 -20.8 03/31/2005 11:30:00 5.4 0.5 6.5 3.8 5.3 0.6 6.5 3.8 0.4 0 0.4 0.4 26 5 35 305 2 0 2 0 -20.3 0.1 -20.1 -20.6 03/31/2005 11:40:00 5.1 0.5 6.5 3.8 5.1 0.5 6.5 3.4 0.4 0 0.4 0.4 26 6 38 305 2 0 2 0 -20.2 0 -19.9 -20.2 03/31/2005 11:50:00 5.1 0.4 6.1 4.2 5.1 0.4 6.1 4.2 0.4 0 0.4 0.4 30 6 24 305 2 0 2 0 -20.2 0 -19.9 -20.2 03/31/2005 12:00:00 5.3 0.6 6.5 3.8 5.2 0.6 6.5 3 0.4 0 0.4 0.4 30 5 27 305 2 0 1 0 -20.1 0.1 -19.5 -20.1 03/31/2005 12:10:00 4.8 0.4 5.7 3.4 4.7 0.5 5.7 3.4 0.4 0 0.4 0.4 26 8 32 305 1 0 1 0 -19.9 0 -19.5 -20.1 03/31/2005 12:20:00 5.3 0.5 6.5 4.2 5.2 0.5 6.5 4.2 0.4 0 0.4 0.4 31 5 30 305 1 0 1 0 -19.9 0 -19.5 -20.1 03/31/2005 12:30:00 5.5 0.6 6.8 3.8 5.5 0.6 6.8 3.8 0.4 0 0.4 0.4 31 5 35 305 1 0 1 0 -19.7 0.1 -19.3 -20.1 03/31/2005 12:40:00 5.2 0.5 6.1 4.2 5.2 0.5 6.5 4.2 0.4 0 0.4 0.4 34 5 34 305 1 0 1 0 -19.6 0 -19.2 -19.7 03/31/2005 12:50:00 5.1 0.4 6.1 3.8 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 25 5 23 305 1 0 1 0 -19.5 0.1 -19 -19.7 03/31/2005 13:00:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 3.8 0.4 0 0.4 0.4 31 5 25 305 1 0 1 0 -19.5 0.1 -19.2 -19.5 03/31/2005 13:10:00 6.2 0.5 7.2 4.9 6.1 0.5 7.2 4.6 0.4 0 0.4 0.4 31 4 22 305 1 0 1 0 -19.5 0.1 -19 -19.5 03/31/2005 13:20:00 5.5 0.5 6.8 3.8 5.5 0.5 6.8 3.8 0.4 0 0.4 0.4 32 5 28 305 1 0 1 0 -19.3 0 -19 -19.5 03/31/2005 13:30:00 5.1 0.5 6.5 3.4 5.1 0.5 6.5 3.4 0.4 0 0.4 0.4 36 5 40 305 1 0 1 0 -19.2 0.1 -19 -19.5 03/31/2005 13:40:00 4.9 0.4 6.1 3.8 4.8 0.5 6.1 3.4 0.4 0 0.4 0.4 34 6 32 305 1 0 1 0 -19 0 -18.6 -19.2 03/31/2005 13:50:00 4.9 0.4 6.1 3.8 4.9 0.5 6.1 3.8 0.4 0 0.4 0.4 31 5 28 305 1 0 1 0 -19 0.1 -18.6 -19.2 03/31/2005 14:00:00 4.4 0.6 6.5 3.4 4.3 0.6 6.5 3 0.4 0 0.4 0.4 30 6 35 305 1 0 1 0 -18.8 0.1 -18.4 -19 03/31/2005 14:10:00 3.8 0.4 4.6 3 3.7 0.4 4.9 2.6 0.4 0 0.4 0.4 33 6 37 305 1 0 1 0 -18.6 0 -18.2 -18.8 03/31/2005 14:20:00 4.3 0.4 5.3 3.4 4.2 0.4 5.7 3.4 0.4 0 0.4 0.4 35 6 38 305 1 0 0 0 -18.5 0 -18.1 -18.8 03/31/2005 14:30:00 5 0.3 6.1 4.2 5 0.4 6.1 4.2 0.4 0 0.4 0.4 39 4 40 305 1 0 1 0 -18.7 0.1 -18.2 -18.8 03/31/2005 14:40:00 5.2 0.4 6.5 4.2 5.2 0.5 6.5 3.4 0.4 0 0.4 0.4 40 6 45 305 0 0 1 0 -18.6 0.1 -18.2 -18.8 03/31/2005 14:50:00 5.4 0.6 6.8 3.8 5.2 0.6 6.8 3.8 0.4 0 0.4 0.4 34 6 33 305 1 0 1 0 -18.4 0.1 -18.1 -18.4 03/31/2005 15:00:00 5.2 0.5 7.2 4.2 5.1 0.5 7.6 3.8 0.4 0 0.4 0.4 32 7 42 305 1 0 1 0 -18.2 0.1 -17.9 -18.4 03/31/2005 15:10:00 5.4 0.6 6.5 3.4 5.4 0.6 6.5 3.4 0.4 0 0.4 0.4 34 6 41 305 1 0 0 0 -18.2 0.1 -17.7 -18.4 03/31/2005 15:20:00 5.9 0.5 7.2 4.6 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 36 6 32 305 0 0 0 0 -18.1 0 -18.1 -18.4 03/31/2005 15:30:00 6.4 0.6 8 4.9 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 37 7 44 305 0 0 0 0 -18.1 0 -17.7 -18.2 03/31/2005 15:40:00 6.7 0.6 7.6 4.9 6.7 0.6 8 4.9 0.4 0 0.4 0.4 40 5 42 305 0 0 1 0 -18.2 0.1 -17.9 -18.4 03/31/2005 15:50:00 7.3 0.6 9.1 5.3 7.2 0.6 9.1 5.7 0.4 0 0.4 0.4 36 5 36 305 0 0 0 0 -18.1 0 -17.9 -18.4 03/31/2005 16:00:00 7.2 0.6 8.8 5.3 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 34 6 41 305 0 0 0 0 -18.1 0 -17.9 -18.4 03/31/2005 16:10:00 7.4 0.6 8.8 5.7 7.3 0.7 8.8 5.7 0.4 0 0.4 0.4 29 5 32 305 0 0 0 0 -18.2 0.1 -17.9 -18.4 03/31/2005 16:20:00 7.3 0.6 8.4 5.7 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 31 4 32 305 0 0 0 0 -18.2 0 -18.1 -18.4 03/31/2005 16:30:00 7.2 0.5 8.4 6.1 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 34 7 29 305 0 0 0 0 -18.1 0 -17.9 -18.2 03/31/2005 16:40:00 6.5 0.7 8.4 4.6 6.5 0.7 8.4 4.2 0.4 0 0.4 0.4 37 8 27 305 0 0 1 0 -18.1 0 -17.7 -18.4 03/31/2005 16:50:00 6.6 0.6 8 4.6 6.5 0.6 8 4.9 0.4 0 0.4 0.4 30 5 35 305 0 0 0 0 -18 0 -17.5 -18.2 03/31/2005 17:00:00 6.9 0.6 8.8 5.3 6.8 0.6 8.4 5.7 0.4 0 0.4 0.4 36 7 21 305 0 0 1 0 -17.9 0.1 -17.5 -18.1 03/31/2005 17:10:00 7.3 0.7 9.1 5.3 7.3 0.8 9.1 4.9 0.4 0 0.4 0.4 28 6 27 305 0 0 0 0 -18 0 -17.7 -18.1 03/31/2005 17:20:00 7.2 0.5 8.8 5.7 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 32 5 33 305 0 0 0 0 -18 0 -17.7 -18.1 03/31/2005 17:30:00 7 0.6 8.4 5.3 6.9 0.6 8.8 5.3 0.4 0 0.4 0.4 34 6 22 305 0 0 0 0 -17.9 0.1 -17.5 -18.1 03/31/2005 17:40:00 7.1 0.6 8.8 5.3 7 0.6 8.8 5.3 0.4 0 0.4 0.4 33 7 35 305 0 0 1 0 -17.9 0 -17.5 -18.1 03/31/2005 17:50:00 6.9 0.8 8.4 5.3 6.9 0.8 8.4 5.3 0.4 0 0.4 0.4 31 6 32 305 0 0 0 0 -17.9 0 -17.5 -18.1 03/31/2005 18:00:00 7.1 0.5 8.4 5.3 7 0.5 8 6.1 0.4 0 0.4 0.4 34 5 41 305 0 0 1 0 -17.9 0.1 -17.5 -18.1 03/31/2005 18:10:00 6.4 0.7 7.6 4.6 6.3 0.7 8 4.2 0.4 0 0.4 0.4 39 7 51 305 0 0 0 0 -17.9 0.1 -17.5 -18.1 03/31/2005 18:20:00 6.5 0.6 8 4.6 6.5 0.6 8 4.6 0.4 0 0.4 0.4 45 7 35 305 0 0 0 0 -17.9 0.1 -17.5 -18.1 03/31/2005 18:30:00 6.3 0.6 7.6 4.6 6.1 0.7 7.6 4.2 0.4 0 0.4 0.4 46 7 46 305 0 0 1 0 -18.1 0 -17.9 -18.4 03/31/2005 18:40:00 6.8 0.7 8.4 5.3 6.8 0.7 8.4 4.9 0.4 0 0.4 0.4 49 5 54 305 1 0 1 0 -18.1 0 -17.9 -18.4 03/31/2005 18:50:00 6.8 0.5 8 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 48 3 48 305 0 0 1 0 -18.3 0.1 -18.1 -18.4 03/31/2005 19:00:00 6.7 0.6 8 4.9 6.7 0.6 8 4.9 0.4 0 0.4 0.4 45 5 44 305 0 0 0 0 -18.4 0 -18.1 -18.6 03/31/2005 19:10:00 6.3 0.5 7.6 4.9 6.3 0.5 7.2 4.9 0.4 0 0.4 0.4 44 5 45 305 1 0 0 0 -18.3 0.1 -18.1 -18.4 03/31/2005 19:20:00 6.4 0.6 7.6 4.6 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 46 5 40 305 1 0 1 0 -18.3 0 -18.1 -18.4 03/31/2005 19:30:00 6 0.5 7.2 4.6 6 0.6 7.2 4.2 0.4 0 0.4 0.4 42 5 47 305 1 0 1 0 -18.2 0.1 -18.1 -18.4 03/31/2005 19:40:00 6.2 0.6 7.6 4.6 6.1 0.7 7.6 4.6 0.4 0 0.4 0.4 32 5 33 305 1 0 1 0 -18.4 0 -18.1 -18.4 03/31/2005 19:50:00 6.6 0.5 8 5.3 6.5 0.6 8 4.9 0.4 0 0.4 0.4 34 5 40 305 1 0 1 0 -18.5 0 -18.2 -18.6 03/31/2005 20:00:00 6.5 0.6 7.6 4.9 6.4 0.6 7.6 4.6 0.4 0 0.4 0.4 35 5 35 305 1 0 1 0 -18.6 0 -18.4 -18.8 03/31/2005 20:10:00 6.7 0.6 8 4.9 6.5 0.6 8 4.9 0.4 0 0.4 0.4 31 4 27 305 1 0 1 0 -18.4 0 -18.2 -18.4 03/31/2005 20:20:00 6.7 0.8 8 4.9 6.6 0.8 8 4.9 0.4 0 0.4 0.4 30 4 33 305 1 0 1 0 -18.7 0.1 -18.4 -19 03/31/2005 20:30:00 6.6 0.6 8 4.6 6.4 0.6 8 4.6 0.4 0 0.4 0.4 32 5 30 305 1 0 1 0 -18.8 0 -18.6 -19 03/31/2005 20:40:00 6.4 0.6 7.6 4.6 6.1 0.6 7.2 4.6 0.4 0 0.4 0.4 31 4 29 305 1 0 1 0 -18.8 0 -18.6 -19 03/31/2005 20:50:00 5.9 0.5 7.2 4.9 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 29 4 30 305 1 0 1 0 -18.8 0 -18.6 -19 03/31/2005 21:00:00 7 0.5 8 5.3 6.8 0.6 8 5.3 0.4 0 0.4 0.4 32 4 33 305 1 0 1 0 -19 0 -18.8 -19 03/31/2005 21:10:00 6.9 0.4 7.6 5.7 6.6 0.4 7.6 5.7 0.4 0 0.4 0.4 32 3 33 305 1 0 1 0 -19 0 -18.8 -19 03/31/2005 21:20:00 6.2 0.5 7.2 4.9 6.1 0.5 7.2 4.6 0.4 0 0.4 0.4 33 4 35 305 1 0 1 0 -19 0 -18.8 -19 03/31/2005 21:30:00 6.1 0.6 7.6 4.6 5.9 0.7 7.2 4.2 0.4 0 0.4 0.4 31 4 31 305 1 0 1 0 -19.1 0 -19 -19.2 03/31/2005 21:40:00 6.5 0.5 8 4.9 6.3 0.5 7.6 4.9 0.4 0 0.4 0.4 31 4 27 305 1 0 1 0 -19.1 0 -19 -19.2 03/31/2005 21:50:00 6.8 0.6 8 4.6 6.6 0.6 7.6 4.6 0.4 0 0.4 0.4 30 4 28 305 1 0 1 0 -19.1 0 -19 -19.2 03/31/2005 22:00:00 7.1 0.4 8.4 5.7 6.9 0.5 8.4 5.7 0.4 0 0.4 0.4 29 3 33 305 2 0 1 0 -19.1 0 -19 -19.2 03/31/2005 22:10:00 7.1 0.5 8 5.7 6.9 0.6 8 5.3 0.4 0 0.4 0.4 29 3 24 305 2 0 1 0 -19.1 0 -19 -19.2 03/31/2005 22:20:00 7.2 0.5 8.4 6.1 7 0.5 8.4 6.1 0.4 0 0.4 0.4 31 3 33 305 2 0 2 0 -19.1 0 -19 -19.2 03/31/2005 22:30:00 7.4 0.6 8.8 5.7 7.2 0.6 8.4 5.7 0.4 0 0.4 0.4 30 3 36 305 2 0 2 0 -19.2 0 -19 -19.3 03/31/2005 22:40:00 7 0.5 8 5.7 6.7 0.6 8 5.3 0.4 0 0.4 0.4 32 4 31 305 2 0 2 0 -19.2 0 -19 -19.3 03/31/2005 22:50:00 7.2 0.6 8.8 5.7 7 0.6 8.8 5.3 0.4 0 0.4 0.4 33 4 35 305 2 0 2 0 -19.2 0 -19 -19.3 03/31/2005 23:00:00 7.9 0.8 9.1 5.7 7.6 0.9 9.1 5.7 0.4 0 0.4 0.4 31 4 36 305 2 0 2 0 -19.2 0 -19 -19.5 03/31/2005 23:10:00 7.8 0.8 9.1 6.1 7.6 0.8 9.1 5.7 0.4 0 0.4 0.4 31 4 31 305 2 0 2 0 -19.1 0 -19 -19.2 03/31/2005 23:20:00 8.4 0.6 9.5 6.5 8.1 0.7 9.5 6.5 0.4 0 0.4 0.4 37 4 42 305 2 0 2 0 -19.2 0 -19 -19.3 03/31/2005 23:30:00 7.8 0.6 9.1 6.1 7.6 0.7 9.1 6.1 0.4 0 0.4 0.4 36 4 37 305 2 0 2 0 -19.2 0 -19 -19.3 03/31/2005 23:40:00 7.6 0.5 8.8 6.1 7.4 0.5 8.8 6.1 0.4 0 0.4 0.4 35 4 34 305 2 0 2 0 -19.2 0 -19 -19.3 03/31/2005 23:50:00 8.1 0.7 9.9 6.5 7.9 0.7 9.9 6.5 0.4 0 0.4 0.4 34 4 35 305 2 0 2 0 -19.2 0 -19 -19.3 04/01/2005 00:00:00 8.5 0.6 9.9 6.8 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 34 3 29 305 2 0 3 0 -19.1 0 -18.6 -19.2 04/01/2005 00:10:00 8.4 0.7 9.9 6.8 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 32 4 35 305 2 0 2 0 -19.2 0 -19 -19.3 04/01/2005 00:20:00 8.6 0.5 9.9 7.2 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 33 4 36 305 2 0 2 0 -19.2 0 -19 -19.3 04/01/2005 00:30:00 8.6 0.6 10.3 7.2 8.4 0.6 9.9 6.5 0.4 0 0.4 0.4 31 4 32 305 2 0 3 0 -19.1 0 -19 -19.3 04/01/2005 00:40:00 8.7 0.5 10.3 7.2 8.5 0.6 10.3 6.8 0.4 0 0.4 0.4 31 3 26 305 2 0 2 0 -19.2 0 -19 -19.3 04/01/2005 00:50:00 7.5 0.7 9.5 5.3 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 32 4 33 305 3 0 2 0 -19.2 0 -19 -19.3 04/01/2005 01:00:00 7.7 0.6 9.5 6.1 7.6 0.6 8.8 5.7 0.4 0 0.4 0.4 33 5 28 305 3 0 3 0 -19.2 0 -19 -19.5 04/01/2005 01:10:00 7.9 0.5 8.8 6.8 7.8 0.5 9.1 6.5 0.4 0 0.4 0.4 36 5 33 305 3 0 2 0 -19.3 0 -19.2 -19.5 04/01/2005 01:20:00 7.7 0.7 9.5 6.1 7.7 0.7 9.9 6.1 0.4 0 0.4 0.4 35 5 39 305 3 0 2 0 -19.3 0 -19.2 -19.5 04/01/2005 01:30:00 7.8 0.6 9.5 6.1 7.6 0.7 9.1 6.1 0.4 0 0.4 0.4 39 5 29 305 3 0 2 0 -19.4 0 -19 -19.5 04/01/2005 01:40:00 8.6 0.7 10.3 6.8 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 33 5 30 305 3 0 3 0 -19.3 0 -18.8 -19.5 04/01/2005 01:50:00 9.3 0.5 10.7 7.6 9.2 0.6 10.3 7.6 0.4 0 0.4 0.4 30 3 30 305 3 0 3 0 -19.4 0 -18.8 -19.5 04/01/2005 02:00:00 9.7 0.6 11.5 7.6 9.5 0.6 11.5 7.6 0.4 0 0.4 0.4 31 3 32 305 3 0 3 0 -19.3 0 -19.2 -19.5 04/01/2005 02:10:00 9.7 0.6 11.1 8 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 32 4 32 305 3 0 3 0 -19.4 0 -18.8 -19.5 04/01/2005 02:20:00 9.4 0.8 11.1 7.6 9.3 0.9 11.5 7.2 0.4 0 0.4 0.4 33 5 34 305 3 0 3 0 -19.5 0 -19 -19.5 04/01/2005 02:30:00 9.1 0.7 11.1 7.2 8.8 0.8 10.7 6.8 0.4 0 0.4 0.4 33 5 32 305 3 0 3 0 -19.5 0 -19 -19.5 04/01/2005 02:40:00 9.5 0.6 11.1 7.6 9.3 0.7 10.7 7.6 0.4 0 0.4 0.4 32 3 35 305 3 0 3 0 -19.6 0 -19 -19.5 04/01/2005 02:50:00 9.5 0.5 10.7 7.6 9.4 0.6 10.7 7.2 0.4 0 0.4 0.4 32 3 35 305 3 0 3 0 -19.6 0 -19 -19.7 04/01/2005 03:00:00 9 0.7 10.7 7.2 8.8 0.9 10.3 6.8 0.4 0 0.4 0.4 36 4 38 305 3 0 0 0 -19.7 0 -19.5 -20.1 04/01/2005 03:10:00 9.1 0.7 10.3 7.2 9 0.8 10.3 6.5 0.4 0 0.4 0.4 37 5 37 305 3 0 3 0 -19.8 0 -19.5 -20.1 04/01/2005 03:20:00 8.2 0.8 10.3 6.1 8 0.9 10.3 5.7 0.4 0 0.4 0.4 33 5 33 305 3 0 3 0 -19.8 0 -19.5 -20.1 04/01/2005 03:30:00 9.2 0.6 10.7 6.8 9.2 0.7 10.7 7.2 0.4 0 0.4 0.4 35 4 37 305 3 0 3 0 -19.9 0 -19.7 -20.1 04/01/2005 03:40:00 8.9 0.5 9.9 7.6 8.8 0.5 9.9 6.8 0.4 0 0.4 0.4 35 3 32 305 3 0 3 0 -19.9 0 -19.7 -20.1 04/01/2005 03:50:00 7.9 0.7 9.5 5.7 7.7 0.7 9.5 5.7 0.4 0 0.4 0.4 41 5 40 305 3 0 3 0 -20.1 0 -19.9 -20.1 04/01/2005 04:00:00 7.7 0.8 9.5 5.7 7.6 0.9 9.5 5.7 0.4 0 0.4 0.4 37 5 36 305 3 0 3 0 -20.1 0 -19.9 -20.1 04/01/2005 04:10:00 8.1 0.7 9.5 6.5 7.9 0.8 9.9 5.7 0.4 0 0.4 0.4 38 4 33 305 3 0 3 0 -20.1 0 -19.9 -20.1 04/01/2005 04:20:00 8.5 0.6 9.9 6.5 8.4 0.6 9.9 6.1 0.4 0 0.4 0.4 38 4 36 305 3 0 3 0 -20.1 0 -19.9 -20.2 04/01/2005 04:30:00 8.6 0.6 9.9 6.8 8.5 0.6 10.3 6.8 0.4 0 0.4 0.4 37 4 36 305 3 0 3 0 -20.2 0 -20.1 -20.1 04/01/2005 04:40:00 7.7 0.7 9.5 5.7 7.5 0.8 9.1 5.7 0.4 0 0.4 0.4 38 6 43 305 3 0 3 0 -20.2 0 -20.1 -20.2 04/01/2005 04:50:00 7.7 0.8 9.5 5.7 7.6 0.9 9.5 5.7 0.4 0 0.4 0.4 41 5 46 305 3 0 3 0 -20.2 0 -20.1 -20.4 04/01/2005 05:00:00 8 0.6 9.1 6.1 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 45 4 42 305 3 0 3 0 -20.3 0 -20.1 -20.4 04/01/2005 05:10:00 8 0.6 9.5 6.1 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 46 3 47 305 3 0 3 0 -20.4 0 -20.1 -20.6 04/01/2005 05:20:00 7.7 0.4 8.8 6.5 7.6 0.5 8.8 6.1 0.4 0 0.4 0.4 47 4 40 305 3 0 3 0 -20.4 0 -19.9 -20.6 04/01/2005 05:30:00 7.9 0.5 8.8 6.5 7.8 0.5 8.8 6.5 0.4 0 0.4 0.4 46 3 46 305 3 0 3 0 -20.4 0 -20.2 -20.6 04/01/2005 05:40:00 7 0.6 8.4 5.7 6.9 0.5 8.4 5.3 0.4 0 0.4 0.4 47 5 43 305 3 0 3 0 -20.5 0 -20.2 -20.6 04/01/2005 05:50:00 7.6 0.4 8.4 6.1 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 47 4 48 305 3 0 3 0 -20.6 0 -20.4 -20.8 04/01/2005 06:00:00 6.7 0.6 8 5.3 6.6 0.6 8 4.9 0.4 0 0.4 0.4 43 4 44 305 3 0 3 0 -20.5 0 -20.2 -20.8 04/01/2005 06:10:00 6.6 0.7 8 4.9 6.5 0.7 8 4.6 0.4 0 0.4 0.4 41 5 45 305 3 0 3 0 -20.6 0.1 -20.2 -20.8 04/01/2005 06:20:00 7.1 0.7 8.4 5.3 7 0.7 8.4 4.9 0.4 0 0.4 0.4 39 4 39 305 3 0 3 0 -20.5 0 -20.2 -20.8 04/01/2005 06:30:00 7.1 0.6 8.4 5.7 6.9 0.6 8.4 5.7 0.4 0 0.4 0.4 38 4 29 305 3 0 3 0 -20.6 0 -20.2 -20.8 04/01/2005 06:40:00 7.5 0.7 8.8 6.1 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 34 5 33 305 3 0 3 0 -20.5 0 -20.2 -20.8 04/01/2005 06:50:00 7.2 0.6 8.8 5.7 7.1 0.7 8.8 4.9 0.4 0 0.4 0.4 41 4 43 305 3 0 3 0 -20.6 0.1 -19.9 -20.8 04/01/2005 07:00:00 6.8 0.6 8.4 5.7 6.7 0.7 8.4 5.3 0.4 0 0.4 0.4 40 4 40 305 3 0 3 0 -20.6 0 -20.4 -20.8 04/01/2005 07:10:00 7.7 0.5 8.8 6.5 7.6 0.5 8.8 6.5 0.4 0 0.4 0.4 39 3 39 305 3 0 3 0 -20.6 0 -20.4 -20.8 04/01/2005 07:20:00 6.8 0.6 8 5.3 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 38 3 42 305 3 0 3 0 -20.6 0 -20.4 -20.8 04/01/2005 07:30:00 6.8 0.5 8 5.3 6.6 0.6 7.6 4.9 0.4 0 0.4 0.4 36 4 30 305 3 0 3 0 -20.6 0 -20.4 -20.8 04/01/2005 07:40:00 6.6 0.4 7.6 5.7 6.5 0.4 7.6 5.3 0.4 0 0.4 0.4 38 4 44 305 3 0 3 0 -20.6 0 -20.4 -20.8 04/01/2005 07:50:00 6.5 0.5 7.2 5.3 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 41 4 41 305 3 0 3 0 -20.6 0 -20.4 -20.8 04/01/2005 08:00:00 6.7 0.5 7.6 4.9 6.6 0.6 7.6 4.6 0.4 0 0.4 0.4 39 3 32 305 3 0 3 0 -20.6 0.1 -20.4 -20.8 04/01/2005 08:10:00 6.6 0.7 8 4.6 6.5 0.7 8.4 4.9 0.4 0 0.4 0.4 41 4 44 305 3 0 3 0 -20.6 0.1 -20.4 -20.8 04/01/2005 08:20:00 7 0.4 8 6.1 6.8 0.5 8 5.7 0.4 0 0.4 0.4 42 3 41 305 3 0 3 0 -20.6 0 -20.4 -20.8 04/01/2005 08:30:00 6.9 0.5 8 5.7 6.8 0.5 8 4.9 0.4 0 0.4 0.4 42 3 47 305 3 0 3 0 -20.5 0 -20.4 -20.8 04/01/2005 08:40:00 6.3 0.5 7.2 5.3 6.3 0.5 7.2 5.3 0.4 0 0.4 0.4 39 4 44 305 3 0 3 0 -20.5 0 -20.2 -20.8 04/01/2005 08:50:00 6.5 0.5 7.6 5.3 6.5 0.6 8 4.9 0.4 0 0.4 0.4 37 4 41 305 3 0 3 0 -20.3 0 -20.1 -20.6 04/01/2005 09:00:00 6.7 0.5 8 5.3 6.6 0.6 8 5.3 0.4 0 0.4 0.4 35 5 33 305 3 0 3 0 -20.2 0 -20.1 -20.2 04/01/2005 09:10:00 6.5 0.6 8 5.3 6.4 0.6 8 4.9 0.4 0 0.4 0.4 33 5 26 305 3 0 3 0 -20.2 0 -20.1 -20.2 04/01/2005 09:20:00 7 0.7 8.4 5.3 6.8 0.8 8.8 4.9 0.4 0 0.4 0.4 35 5 42 305 3 0 3 0 -20.2 0 -19.9 -20.2 04/01/2005 09:30:00 7.4 0.5 8.8 6.1 7.4 0.5 8.8 6.1 0.4 0 0.4 0.4 38 3 41 305 3 0 4 0 -20.1 0.1 -19.7 -20.1 04/01/2005 09:40:00 6.3 0.6 8.4 4.9 6.1 0.6 8.4 4.9 0.4 0 0.4 0.4 37 5 38 305 4 0 4 0 -19.9 0 -19.5 -20.1 04/01/2005 09:50:00 7.4 0.5 8.4 5.7 7.3 0.5 8.4 5.3 0.4 0 0.4 0.4 37 3 36 305 4 0 4 0 -19.7 0.1 -19.5 -20.1 04/01/2005 10:00:00 6.7 0.6 8 4.9 6.6 0.7 8 4.9 0.4 0 0.4 0.4 34 7 37 305 4 0 4 0 -19.7 0 -19.5 -19.9 04/01/2005 10:10:00 6.9 0.6 8.4 4.9 6.9 0.7 8.4 4.9 0.4 0 0.4 0.4 24 5 23 305 3 0 4 0 -19.6 0 -19.5 -19.7 04/01/2005 10:20:00 6.6 0.8 8 4.9 6.5 0.7 8 4.6 0.4 0 0.4 0.4 22 5 22 305 3 0 3 0 -19.6 0 -19.3 -19.7 04/01/2005 10:30:00 6.1 0.6 7.2 4.2 6.1 0.6 7.2 4.6 0.4 0 0.4 0.4 26 5 36 305 3 0 3 0 -19.4 0 -19 -19.5 04/01/2005 10:40:00 6.4 0.4 7.2 4.9 6.5 0.5 7.2 5.3 0.4 0 0.4 0.4 23 3 22 305 3 0 3 0 -19.4 0 -19.2 -19.5 04/01/2005 10:50:00 6.4 0.4 7.2 5.3 6.3 0.5 7.2 4.9 0.4 0 0.4 0.4 26 4 25 305 3 0 3 0 -19.3 0 -19 -19.5 04/01/2005 11:00:00 6.5 0.5 8 5.3 6.4 0.5 8 5.3 0.4 0 0.4 0.4 27 4 27 305 3 0 2 0 -19.2 0.1 -19 -19.5 04/01/2005 11:10:00 6.4 0.5 7.6 4.9 6.4 0.6 7.6 4.6 0.4 0 0.4 0.4 26 5 23 305 2 0 2 0 -19.2 0 -19 -19.3 04/01/2005 11:20:00 6.3 0.5 7.2 4.9 6.2 0.5 7.2 4.9 0.4 0 0.4 0.4 24 4 27 305 2 0 2 0 -19.1 0 -18.4 -19.2 04/01/2005 11:30:00 6.2 0.4 7.2 4.6 6.2 0.5 7.2 4.6 0.4 0 0.4 0.4 26 4 25 305 2 0 2 0 -19 0 -18.4 -19.2 04/01/2005 11:40:00 6 0.6 7.2 4.6 6 0.6 7.6 4.6 0.4 0 0.4 0.4 29 4 30 305 2 0 2 0 -18.9 0.1 -18.4 -19 04/01/2005 11:50:00 5.9 0.5 7.2 4.2 5.9 0.5 7.2 4.2 0.4 0 0.4 0.4 25 6 33 305 2 0 2 0 -18.8 0.1 -18.4 -19 04/01/2005 12:00:00 6.2 0.5 7.2 4.9 6.2 0.6 7.6 4.9 0.4 0 0.4 0.4 25 6 11 305 2 0 2 0 -18.7 0 -18.4 -19 04/01/2005 12:10:00 6.2 0.4 7.2 4.9 6.1 0.5 7.2 4.9 0.4 0 0.4 0.4 26 6 20 305 2 0 2 0 -18.6 0 -18.2 -18.8 04/01/2005 12:20:00 5.9 0.5 6.8 4.2 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 30 5 29 305 2 0 2 0 -18.4 0.1 -18.1 -18.6 04/01/2005 12:30:00 6 0.5 7.2 4.6 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 32 4 25 305 2 0 2 0 -18.3 0.1 -18.1 -18.4 04/01/2005 12:40:00 5.7 0.7 7.2 4.2 5.6 0.8 7.2 3.8 0.4 0 0.4 0.4 30 6 27 305 1 0 2 0 -18.1 0.1 -17.5 -18.4 04/01/2005 12:50:00 6.1 0.5 7.2 4.6 6 0.5 7.2 4.2 0.4 0 0.4 0.4 29 5 33 305 1 0 1 0 -18.1 0.1 -17.5 -18.2 04/01/2005 13:00:00 6.3 0.5 7.6 4.6 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 30 5 34 305 1 0 1 0 -18 0 -17.7 -18.2 04/01/2005 13:10:00 6.2 0.5 7.6 4.9 6.1 0.5 7.2 4.9 0.4 0 0.4 0.4 29 6 26 305 1 0 1 0 -17.9 0.1 -17.5 -18.1 04/01/2005 13:20:00 6.3 0.5 7.6 4.9 6.2 0.5 7.6 4.9 0.4 0 0.4 0.4 30 5 25 305 1 0 1 0 -17.7 0 -17.5 -17.9 04/01/2005 13:30:00 6.1 0.6 8 4.2 6 0.6 8 4.2 0.4 0 0.4 0.4 28 6 30 305 1 0 1 0 -17.5 0.1 -17.1 -17.9 04/01/2005 13:40:00 6.2 0.6 7.6 4.9 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 29 5 30 305 1 0 1 0 -17.4 0.1 -16.9 -17.5 04/01/2005 13:50:00 6.9 0.6 8 5.3 6.8 0.5 8 5.3 0.4 0 0.4 0.4 26 5 31 305 1 0 1 0 -17.4 0.1 -16.9 -17.5 04/01/2005 14:00:00 6.7 0.5 8 5.3 6.6 0.5 8 4.9 0.4 0 0.4 0.4 26 4 20 305 1 0 1 0 -17.3 0.1 -16.9 -17.5 04/01/2005 14:10:00 6.2 0.6 7.6 4.6 6.2 0.7 8 4.6 0.4 0 0.4 0.4 27 5 32 305 1 0 1 0 -17.2 0.1 -16.9 -17.5 04/01/2005 14:20:00 6.1 0.6 8 4.2 6.1 0.6 8 4.6 0.4 0 0.4 0.4 26 5 31 305 1 0 1 0 -17.1 0.1 -16.9 -17.3 04/01/2005 14:30:00 5.8 0.6 7.6 4.6 5.7 0.7 7.6 4.2 0.4 0 0.4 0.4 23 6 24 305 1 0 1 0 -17 0.1 -16.6 -17.3 04/01/2005 14:40:00 6.3 0.5 7.2 4.6 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 29 5 31 305 1 0 1 0 -17.1 0 -16.7 -17.3 04/01/2005 14:50:00 6.4 0.6 7.6 4.6 6.4 0.6 8 4.6 0.4 0 0.4 0.4 28 5 35 305 1 0 1 0 -17 0 -16.6 -17.3 04/01/2005 15:00:00 6.4 0.4 7.6 4.9 6.3 0.5 7.6 4.6 0.4 0 0.4 0.4 27 6 26 305 1 0 1 0 -17 0 -16.6 -17.3 04/01/2005 15:10:00 6.4 0.6 7.6 4.9 6.4 0.6 7.6 4.9 0.4 0 0.4 0.4 26 6 25 305 1 0 1 0 -17 0 -16.6 -17.1 04/01/2005 15:20:00 6.3 0.7 8.4 4.6 6.2 0.7 8 4.6 0.4 0 0.4 0.4 24 7 359 305 1 0 1 0 -17 0.1 -16.4 -17.3 04/01/2005 15:30:00 6.4 0.5 8 4.9 6.4 0.6 8 4.9 0.4 0 0.4 0.4 13 6 17 305 1 0 1 0 -16.8 0.1 -16.4 -16.9 04/01/2005 15:40:00 6.6 0.7 8 4.6 6.6 0.7 8 4.6 0.4 0 0.4 0.4 10 6 21 305 1 0 1 0 -16.8 0.1 -16.2 -16.9 04/01/2005 15:50:00 6.5 0.7 8.4 4.6 6.5 0.7 8.8 4.6 0.4 0 0.4 0.4 17 6 8 305 1 0 1 0 -16.9 0 -16.4 -16.9 04/01/2005 16:00:00 6.8 0.6 8.8 5.3 6.8 0.7 8.8 5.3 0.4 0 0.4 0.4 14 7 18 305 1 0 1 0 -16.9 0 -16.6 -16.9 04/01/2005 16:10:00 7 0.7 9.1 4.9 7 0.7 9.1 4.9 0.4 0 0.4 0.4 12 6 24 305 1 0 1 0 -16.9 0 -16.4 -16.9 04/01/2005 16:20:00 6.4 0.6 7.6 4.6 6.4 0.6 7.6 4.6 0.4 0 0.4 0.4 15 5 20 305 1 0 1 0 -16.9 0 -16.4 -16.9 04/01/2005 16:30:00 6.4 0.6 7.6 4.9 6.4 0.7 8 4.9 0.4 0 0.4 0.4 15 7 12 305 1 0 1 0 -16.8 0 -16.4 -16.9 04/01/2005 16:40:00 6.2 0.7 8.4 4.6 6.1 0.7 8.4 4.9 0.4 0 0.4 0.4 20 7 11 305 1 0 1 0 -16.8 0.1 -16.4 -16.9 04/01/2005 16:50:00 6.7 0.6 8.4 4.9 6.7 0.7 8.8 4.9 0.4 0 0.4 0.4 14 4 10 305 1 0 1 0 -16.9 0 -16.4 -16.9 04/01/2005 17:00:00 6.9 0.7 8.4 5.3 7 0.8 8.4 4.6 0.4 0 0.4 0.4 17 5 22 305 1 0 1 0 -16.7 0.1 -16.2 -16.9 04/01/2005 17:10:00 7.1 0.5 8.4 5.7 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 15 4 12 305 1 0 1 0 -16.7 0.1 -16.4 -16.9 04/01/2005 17:20:00 6.7 0.6 8 4.9 6.9 0.6 8.4 5.7 0.4 0 0.4 0.4 11 5 10 305 1 0 1 0 -16.7 0.1 -16.4 -16.9 04/01/2005 17:30:00 6.7 0.7 8 4.9 6.8 0.7 8.4 5.3 0.4 0 0.4 0.4 13 4 12 305 1 0 1 0 -16.7 0.1 -16.4 -16.9 04/01/2005 17:40:00 6.8 0.7 8.8 5.3 7 0.7 8.8 5.3 0.4 0 0.4 0.4 12 5 14 305 1 0 1 0 -16.7 0.1 -16.2 -16.9 04/01/2005 17:50:00 6.7 0.6 8 4.9 6.8 0.6 8 4.6 0.4 0 0.4 0.4 13 5 8 305 1 0 1 0 -16.6 0.2 -16.2 -16.9 04/01/2005 18:00:00 7.2 0.7 8.8 4.9 7.4 0.7 9.1 4.9 0.4 0 0.4 0.4 10 5 0 305 1 0 1 0 -16.7 0.1 -16.4 -16.9 04/01/2005 18:10:00 6.9 0.6 8.4 5.3 7 0.6 8.4 5.3 0.4 0 0.4 0.4 15 5 17 305 1 0 1 0 -16.7 0.1 -16.4 -16.9 04/01/2005 18:20:00 6.7 0.7 8.4 4.9 6.7 0.7 8.4 4.9 0.4 0 0.4 0.4 16 5 12 305 1 0 1 0 -16.8 0.1 -16.4 -16.9 04/01/2005 18:30:00 6.7 0.7 8.8 5.3 6.9 0.7 8.8 4.9 0.4 0 0.4 0.4 16 5 16 305 1 0 1 0 -16.7 0.1 -16.4 -16.9 04/01/2005 18:40:00 6.6 0.6 7.6 4.9 6.6 0.6 8 4.9 0.4 0 0.4 0.4 20 6 16 305 1 0 1 0 -16.7 0.1 -16.4 -16.9 04/01/2005 18:50:00 7 0.8 8.8 5.3 7 0.8 9.1 5.3 0.4 0 0.4 0.4 17 6 18 305 1 0 1 0 -16.7 0.1 -16.4 -16.9 04/01/2005 19:00:00 7 0.5 8.8 5.7 7 0.5 8.4 5.7 0.4 0 0.4 0.4 17 6 16 305 1 0 1 0 -16.7 0.1 -16.4 -16.9 04/01/2005 19:10:00 7.3 0.8 8.8 5.7 7.2 0.8 8.8 4.9 0.4 0 0.4 0.4 23 5 25 305 1 0 1 0 -16.8 0.1 -16.4 -16.9 04/01/2005 19:20:00 6.8 0.7 8.4 5.3 6.8 0.7 8.8 4.9 0.4 0 0.4 0.4 22 5 24 305 1 0 1 0 -16.9 0 -16.6 -16.9 04/01/2005 19:30:00 6.3 0.8 8.4 4.6 6.3 0.8 8.4 4.2 0.4 0 0.4 0.4 20 5 18 305 1 0 1 0 -16.9 0 -16.6 -16.9 04/01/2005 19:40:00 7 1.1 9.1 4.6 7 1.1 9.5 4.2 0.4 0 0.4 0.4 18 5 18 305 1 0 0 0 -16.9 0 -16.6 -17.1 04/01/2005 19:50:00 7.7 0.7 9.5 5.7 7.7 0.7 9.5 6.1 0.4 0 0.4 0.4 20 5 24 305 1 0 1 0 -17 0 -16.7 -17.3 04/01/2005 20:00:00 7.5 0.7 9.1 5.7 7.5 0.7 9.5 5.7 0.4 0 0.4 0.4 20 5 13 305 1 0 1 0 -17.2 0 -16.9 -17.3 04/01/2005 20:10:00 7.5 0.7 8.8 6.1 7.4 0.7 9.1 6.1 0.4 0 0.4 0.4 22 5 19 305 1 0 1 0 -17.2 0 -16.9 -17.3 04/01/2005 20:20:00 7.3 0.8 9.1 4.9 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 23 5 19 305 1 0 1 0 -17.3 0 -17.1 -17.5 04/01/2005 20:30:00 7.2 0.6 8.4 6.1 7 0.5 8.8 6.1 0.4 0 0.4 0.4 28 5 26 305 1 0 1 0 -17.5 0.1 -17.3 -17.9 04/01/2005 20:40:00 7.8 0.6 9.5 5.7 7.8 0.6 9.5 6.5 0.4 0 0.4 0.4 29 5 26 305 1 0 1 0 -17.8 0 -17.5 -18.1 04/01/2005 20:50:00 7.2 0.6 9.1 5.7 7.1 0.6 9.1 5.7 0.4 0 0.4 0.4 30 5 20 305 1 0 1 0 -17.9 0 -17.7 -18.1 04/01/2005 21:00:00 7.7 0.6 9.1 6.1 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 28 5 32 305 1 0 1 0 -18 0 -17.9 -18.1 04/01/2005 21:10:00 7.6 0.6 9.1 6.1 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 31 5 27 305 1 0 1 0 -18.2 0.1 -18.1 -18.4 04/01/2005 21:20:00 7.6 0.7 9.1 6.1 7.5 0.7 8.8 5.7 0.4 0 0.4 0.4 32 4 35 305 1 0 1 0 -18.2 0 -18.1 -18.4 04/01/2005 21:30:00 7.8 0.6 9.5 6.5 7.6 0.6 9.5 6.5 0.4 0 0.4 0.4 33 5 36 305 1 0 1 0 -18.3 0 -18.2 -18.4 04/01/2005 21:40:00 7.7 0.6 9.1 6.1 7.5 0.6 8.8 5.7 0.4 0 0.4 0.4 31 5 41 305 1 0 1 0 -18.5 0 -18.2 -18.4 04/01/2005 21:50:00 7.8 0.5 9.1 6.5 7.6 0.5 8.8 6.5 0.4 0 0.4 0.4 30 5 21 305 1 0 1 0 -18.5 0 -18.4 -18.6 04/01/2005 22:00:00 7.6 0.7 9.5 5.7 7.4 0.8 9.5 5.7 0.4 0 0.4 0.4 26 5 22 305 1 0 1 0 -18.6 0 -18.4 -18.6 04/01/2005 22:10:00 7.8 0.7 9.9 6.1 7.7 0.7 10.3 5.7 0.4 0 0.4 0.4 28 5 24 305 1 0 1 0 -18.6 0 -18.4 -18.8 04/01/2005 22:20:00 8 0.6 9.5 6.5 7.9 0.6 9.5 6.1 0.4 0 0.4 0.4 26 5 27 305 1 0 1 0 -18.7 0 -18.4 -19 04/01/2005 22:30:00 8.2 0.6 9.9 6.5 8 0.7 10.3 6.5 0.4 0 0.4 0.4 27 5 29 305 2 0 1 0 -18.7 0 -18.4 -19 04/01/2005 22:40:00 8.3 0.8 10.3 6.1 8.2 0.8 9.9 6.5 0.4 0 0.4 0.4 27 5 26 305 2 0 2 0 -18.8 0 -18.6 -19 04/01/2005 22:50:00 8.1 0.7 9.5 6.1 7.8 0.7 9.5 5.7 0.4 0 0.4 0.4 27 5 30 305 2 0 2 0 -18.9 0 -18.8 -19 04/01/2005 23:00:00 8 0.6 9.5 6.5 7.8 0.6 9.9 6.5 0.4 0 0.4 0.4 29 4 34 305 2 0 2 0 -18.9 0 -18.8 -19 04/01/2005 23:10:00 8 0.6 9.5 6.5 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 30 4 26 305 2 0 2 0 -18.8 0 -18.6 -19 04/01/2005 23:20:00 8 0.8 11.1 6.5 7.8 0.8 10.3 6.1 0.4 0 0.4 0.4 23 5 19 305 2 0 2 0 -18.9 0 -18.6 -19 04/01/2005 23:30:00 7.8 0.6 9.5 6.1 7.6 0.6 9.5 6.1 0.4 0 0.4 0.4 23 5 16 305 2 0 2 0 -19 0 -18.8 -19 04/01/2005 23:40:00 7.6 0.7 9.5 5.3 7.4 0.7 9.5 5.3 0.4 0 0.4 0.4 24 6 27 305 2 0 2 0 -19.1 0 -19 -19.2 04/01/2005 23:50:00 8.2 0.7 10.7 6.5 8 0.8 10.3 6.1 0.4 0 0.4 0.4 25 5 27 305 2 0 2 0 -19.2 0 -19 -19.3 04/02/2005 00:00:00 8.4 0.6 10.3 6.5 8.1 0.7 9.9 6.5 0.4 0 0.4 0.4 27 5 18 305 2 0 2 0 -19.3 0 -18.8 -19.5 04/02/2005 00:10:00 8.5 0.8 10.3 6.5 8.1 0.7 10.3 6.5 0.4 0 0.4 0.4 27 4 23 305 2 0 2 0 -19.4 0 -19 -19.5 04/02/2005 00:20:00 7 0.5 8.4 5.7 6.8 0.5 8 5.7 0.4 0 0.4 0.4 27 4 25 305 2 0 2 0 -19.4 0 -19.2 -19.5 04/02/2005 00:30:00 6.6 0.6 8.8 4.9 6.3 0.6 8.8 4.9 0.4 0 0.4 0.4 25 5 23 305 2 0 2 0 -19.4 0 -19 -19.5 04/02/2005 00:40:00 7.2 0.6 8.8 6.1 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 25 4 24 305 2 0 2 0 -19.5 0 -19.3 -19.5 04/02/2005 00:50:00 7.3 0.6 8.8 5.7 7.1 0.7 9.1 5.3 0.4 0 0.4 0.4 22 5 19 305 2 0 2 0 -19.5 0 -19 -19.5 04/02/2005 01:00:00 7 0.5 8.4 5.7 6.8 0.5 8 5.3 0.4 0 0.4 0.4 25 4 24 305 2 0 2 0 -19.6 0 -19.5 -19.7 04/02/2005 01:10:00 7.6 0.6 9.1 6.1 7.3 0.6 9.1 5.7 0.4 0 0.4 0.4 29 3 32 305 2 0 2 0 -19.5 0 -19 -19.5 04/02/2005 01:20:00 8.3 0.6 9.5 6.8 8 0.6 9.5 6.1 0.4 0 0.4 0.4 24 5 33 305 2 0 2 0 -19.4 0 -19 -19.5 04/02/2005 01:30:00 7.7 0.5 8.8 6.5 7.6 0.5 8.8 6.5 0.4 0 0.4 0.4 29 6 19 305 2 0 2 0 -19.5 0.1 -19 -19.5 04/02/2005 01:40:00 7.9 0.5 9.5 6.5 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 26 5 46 305 2 0 2 0 -19.7 0 -19.3 -19.7 04/02/2005 01:50:00 8 0.6 9.5 6.5 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 26 5 22 305 2 0 2 0 -19.8 0 -19.3 -20.1 04/02/2005 02:00:00 7.1 0.5 8.8 5.3 7 0.6 8.4 5.3 0.4 0 0.4 0.4 27 5 24 305 2 0 2 0 -20 0 -19.7 -20.1 04/02/2005 02:10:00 7.7 0.5 9.1 6.5 7.4 0.5 9.1 6.1 0.4 0 0.4 0.4 25 5 23 305 2 0 2 0 -20 0 -19.9 -20.1 04/02/2005 02:20:00 7.6 0.6 9.1 5.7 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 29 4 19 305 2 0 2 0 -20 0 -19.9 -20.1 04/02/2005 02:30:00 7.9 0.5 9.1 6.8 7.7 0.5 9.1 6.5 0.4 0 0.4 0.4 28 4 24 305 2 0 2 0 -20.2 0 -20.1 -20.2 04/02/2005 02:40:00 7.4 0.5 9.1 6.5 7.3 0.5 9.1 6.1 0.4 0 0.4 0.4 35 5 42 305 2 0 2 0 -20.1 0 -19.9 -20.1 04/02/2005 02:50:00 7.3 0.6 8.8 6.1 7.3 0.6 9.1 5.7 0.4 0 0.4 0.4 40 4 30 305 2 0 2 0 -20.1 0 -19.9 -20.1 04/02/2005 03:00:00 7.8 0.5 9.1 6.5 7.6 0.5 8.8 6.1 0.4 0 0.4 0.4 36 4 32 305 2 0 2 0 -20.1 0 -19.7 -20.1 04/02/2005 03:10:00 8.5 0.5 9.5 7.2 8.3 0.5 9.5 6.8 0.4 0 0.4 0.4 33 4 35 305 2 0 2 0 -20.1 0 -19.9 -20.2 04/02/2005 03:20:00 8.2 0.5 9.5 6.8 8 0.5 9.5 6.8 0.4 0 0.4 0.4 32 4 30 305 2 0 2 0 -20.2 0 -19.5 -20.2 04/02/2005 03:30:00 7.8 0.5 9.1 6.5 7.6 0.5 8.8 6.1 0.4 0 0.4 0.4 37 4 37 305 2 0 2 0 -20.2 0 -20.1 -20.2 04/02/2005 03:40:00 7.8 0.5 9.1 6.5 7.6 0.5 8.8 6.1 0.4 0 0.4 0.4 42 4 42 305 2 0 2 0 -20.2 0 -20.1 -20.2 04/02/2005 03:50:00 8 0.6 9.1 6.5 7.9 0.6 9.1 6.5 0.4 0 0.4 0.4 41 4 44 305 2 0 2 0 -20.2 0 -20.1 -20.2 04/02/2005 04:00:00 7.6 0.6 9.1 6.1 7.5 0.6 8.8 5.3 0.4 0 0.4 0.4 43 4 42 305 2 0 2 0 -20.2 0 -20.1 -20.2 04/02/2005 04:10:00 6.9 0.5 8.4 6.1 6.8 0.5 8 5.7 0.4 0 0.4 0.4 48 5 44 305 2 0 2 0 -20.2 0 -20.1 -20.2 04/02/2005 04:20:00 6.7 0.5 8 5.3 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 52 5 62 305 2 0 2 0 -20.2 0 -19.7 -20.2 04/02/2005 04:30:00 6.3 0.5 7.6 4.9 6.3 0.5 7.6 4.9 0.4 0 0.4 0.4 45 5 43 305 2 0 2 0 -20.2 0 -20.1 -20.4 04/02/2005 04:40:00 6.3 0.5 8 4.9 6.3 0.5 7.6 5.3 0.4 0 0.4 0.4 48 6 51 305 2 0 2 0 -20.4 0 -20.1 -20.6 04/02/2005 04:50:00 5.9 0.5 7.2 4.6 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 51 5 48 305 2 0 2 0 -20.4 0 -20.1 -20.6 04/02/2005 05:00:00 5.7 0.5 7.2 4.6 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 52 6 48 305 2 0 2 0 -20.3 0 -20.1 -20.4 04/02/2005 05:10:00 6 0.6 7.6 4.6 6.1 0.7 8 4.6 0.4 0 0.4 0.4 50 6 54 305 2 0 2 0 -20.3 0 -20.1 -20.6 04/02/2005 05:20:00 6 0.6 7.6 4.6 6.1 0.6 7.6 4.9 0.4 0 0.4 0.4 46 6 56 305 2 0 2 0 -20.2 0 -20.1 -20.4 04/02/2005 05:30:00 5.9 0.5 7.2 4.6 6 0.5 6.8 4.9 0.4 0 0.4 0.4 44 5 44 305 3 0 3 0 -20.2 0 -20.1 -20.2 04/02/2005 05:40:00 5.8 0.5 6.8 4.6 5.8 0.5 7.2 4.6 0.4 0 0.4 0.4 41 6 43 305 3 0 3 0 -20.2 0 -19.9 -20.1 04/02/2005 05:50:00 5.5 0.4 6.5 4.6 5.4 0.4 6.5 4.6 0.4 0 0.4 0.4 43 5 41 305 3 0 2 0 -20.1 0 -19.9 -20.2 04/02/2005 06:00:00 5.4 0.5 6.8 4.2 5.4 0.5 6.5 3.8 0.4 0 0.4 0.4 44 5 40 305 3 0 2 0 -20.2 0 -20.1 -20.1 04/02/2005 06:10:00 5.1 0.5 6.1 3.8 5 0.5 6.5 3.8 0.4 0 0.4 0.4 42 4 42 305 3 0 2 0 -20.2 0 -19.9 -20.1 04/02/2005 06:20:00 5.2 0.4 6.1 4.2 5.2 0.5 6.1 4.2 0.4 0 0.4 0.4 43 5 36 305 2 0 3 0 -20.2 0 -20.1 -20.2 04/02/2005 06:30:00 5.4 0.5 7.2 4.2 5.4 0.4 6.5 4.2 0.4 0 0.4 0.4 43 6 23 305 2 0 2 0 -20.2 0 -20.1 -20.4 04/02/2005 06:40:00 5.5 0.5 7.2 4.2 5.5 0.6 6.8 3.8 0.4 0 0.4 0.4 33 6 29 305 2 0 2 0 -20.2 0 -20.1 -20.4 04/02/2005 06:50:00 5.7 0.5 7.2 4.6 5.7 0.5 7.2 4.6 0.4 0 0.4 0.4 25 5 33 305 2 0 2 0 -20.2 0 -20.1 -20.4 04/02/2005 07:00:00 6.1 0.5 7.2 4.9 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 21 5 15 305 2 0 2 0 -20.4 0.1 -20.1 -20.6 04/02/2005 07:10:00 5.5 0.4 6.5 4.6 5.4 0.5 6.8 4.2 0.4 0 0.4 0.4 30 9 17 305 2 0 2 0 -20.5 0 -20.2 -20.8 04/02/2005 07:20:00 5.4 0.5 6.8 4.2 5.3 0.4 6.5 4.2 0.4 0 0.4 0.4 30 5 29 305 2 0 2 0 -20.5 0 -20.1 -20.8 04/02/2005 07:30:00 5.2 0.4 6.5 4.2 5.2 0.4 6.5 4.2 0.4 0 0.4 0.4 37 5 33 305 2 0 2 0 -20.5 0 -20.2 -20.8 04/02/2005 07:40:00 6 0.5 7.2 4.9 5.8 0.4 6.8 4.9 0.4 0 0.4 0.4 29 4 37 305 2 0 2 0 -20.5 0 -20.2 -20.8 04/02/2005 07:50:00 5.7 0.5 6.8 4.6 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 40 6 44 305 2 0 2 0 -20.4 0 -20.1 -20.6 04/02/2005 08:00:00 5.7 0.4 6.8 4.6 5.7 0.4 6.8 4.6 0.4 0 0.4 0.4 41 4 44 305 3 0 2 0 -20.2 0 -20.1 -20.2 04/02/2005 08:10:00 5.9 0.5 7.2 4.6 5.8 0.5 7.2 4.9 0.4 0 0.4 0.4 33 6 32 305 3 0 3 0 -20.2 0 -20.1 -20.2 04/02/2005 08:20:00 5.7 0.4 6.8 4.9 5.7 0.4 6.8 4.6 0.4 0 0.4 0.4 30 5 26 305 3 0 3 0 -20.1 0.1 -19.9 -20.1 04/02/2005 08:30:00 5.7 0.5 6.8 4.6 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 37 8 27 305 3 0 3 0 -20.1 0 -19.9 -20.1 04/02/2005 08:40:00 5.9 0.5 6.8 4.2 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 43 5 41 305 3 0 3 0 -20.1 0 -19.9 -20.1 04/02/2005 08:50:00 5.4 0.5 6.5 4.2 5.3 0.5 6.5 4.2 0.4 0 0.4 0.4 53 5 58 305 3 0 3 0 -20.2 0 -19.5 -20.1 04/02/2005 09:00:00 5.8 0.5 6.8 4.6 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 52 6 58 305 3 0 3 0 -20.1 0 -19.9 -20.2 04/02/2005 09:10:00 5.3 0.5 6.8 4.2 5.2 0.5 6.8 4.2 0.4 0 0.4 0.4 47 5 46 305 3 0 3 0 -20 0.1 -19.7 -20.1 04/02/2005 09:20:00 5.2 0.4 6.1 4.2 5.1 0.5 6.5 4.2 0.4 0 0.4 0.4 53 5 61 305 3 0 3 0 -19.9 0 -19.5 -20.1 04/02/2005 09:30:00 5.6 0.5 7.2 4.6 5.6 0.5 6.8 4.6 0.4 0 0.4 0.4 52 7 57 305 3 0 3 0 -19.7 0.1 -19.5 -20.1 04/02/2005 09:40:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 4.6 0.4 0 0.4 0.4 48 5 51 305 3 0 3 0 -19.7 0 -19.3 -19.9 04/02/2005 09:50:00 5.6 0.4 6.8 4.6 5.6 0.5 6.8 4.6 0.4 0 0.4 0.4 52 6 57 305 3 0 3 0 -19.5 0.1 -19 -19.5 04/02/2005 10:00:00 5.6 0.7 7.2 3.8 5.5 0.7 6.8 3.8 0.4 0 0.4 0.4 61 7 68 305 3 0 3 0 -19.3 0.1 -19 -19.5 04/02/2005 10:10:00 6.3 0.6 8 4.9 6.1 0.5 7.6 4.6 0.4 0 0.4 0.4 66 5 69 305 2 0 2 0 -19 0 -19 -19.2 04/02/2005 10:20:00 6.7 0.6 8.4 5.3 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 60 5 66 305 2 0 2 0 -19 0 -18.8 -19.2 04/02/2005 10:30:00 6.4 0.6 7.6 4.9 6.4 0.7 8 4.6 0.4 0 0.4 0.4 60 5 61 305 2 0 2 0 -19.1 0 -18.8 -19.2 04/02/2005 10:40:00 6.6 0.5 8 5.3 6.5 0.5 8 4.9 0.4 0 0.4 0.4 63 4 64 305 2 0 2 0 -19.2 0 -19 -19.3 04/02/2005 10:50:00 6.4 0.5 7.6 5.3 6.4 0.5 7.6 5.3 0.4 0 0.4 0.4 63 4 68 305 2 0 2 0 -19 0.1 -18.6 -19.2 04/02/2005 11:00:00 6 0.4 7.2 4.9 6 0.5 7.2 4.9 0.4 0 0.4 0.4 63 6 70 305 2 0 2 0 -19 0.2 -18.4 -19.3 04/02/2005 11:10:00 5.9 0.6 7.6 4.6 5.9 0.6 7.2 4.6 0.4 0 0.4 0.4 58 5 66 305 2 0 2 0 -18.8 0.1 -18.4 -19 04/02/2005 11:20:00 6.6 0.5 8 5.3 6.6 0.5 7.6 4.9 0.4 0 0.4 0.4 63 5 60 305 2 0 2 0 -18.5 0.1 -18.1 -18.8 04/02/2005 11:30:00 6 0.5 7.2 4.6 5.9 0.5 7.2 4.2 0.4 0 0.4 0.4 64 5 70 305 2 0 2 0 -18.1 0.1 -17.7 -18.4 04/02/2005 11:40:00 5.8 0.5 7.2 4.6 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 62 5 60 305 2 0 2 0 -18.1 0.1 -17.7 -18.4 04/02/2005 11:50:00 5.5 0.5 6.8 4.6 5.4 0.5 6.8 4.2 0.4 0 0.4 0.4 61 7 48 305 2 0 1 0 -17.9 0.1 -17.5 -18.2 04/02/2005 12:00:00 5.5 0.5 6.8 4.2 5.5 0.5 6.8 4.6 0.4 0 0.4 0.4 63 5 61 305 2 0 2 0 -17.6 0.1 -16.9 -18.1 04/02/2005 12:10:00 5.1 0.6 6.5 3.8 5 0.5 6.5 3.8 0.4 0 0.4 0.4 67 5 66 305 1 0 2 0 -17.2 0.1 -16.9 -17.5 04/02/2005 12:20:00 4.1 0.5 5.3 3 4 0.5 4.9 3 0.4 0 0.4 0.4 63 6 62 305 1 0 1 0 -17.2 0.1 -16.6 -17.5 04/02/2005 12:30:00 4 0.5 4.9 2.6 3.9 0.5 4.9 3 0.4 0 0.4 0.4 69 8 62 305 1 0 1 0 -16.6 0.2 -16 -16.9 04/02/2005 12:40:00 3.7 0.5 4.9 2.6 3.5 0.5 4.9 2.6 0.4 0 0.4 0.4 74 6 69 305 1 0 1 0 -15.7 0.4 -14.8 -16.6 04/02/2005 12:50:00 3.5 0.3 4.2 2.6 3.4 0.3 4.2 2.3 0.4 0 0.4 0.4 71 11 56 305 1 0 1 0 -15.8 0.2 -15 -16.4 04/02/2005 13:00:00 3.2 0.5 4.6 1.9 3.1 0.4 3.8 1.9 0.4 0 0.4 0.4 76 8 82 305 1 0 1 0 -14.7 0.2 -14.3 -15.4 04/02/2005 13:10:00 3.5 0.5 4.9 2.3 3.3 0.5 4.6 2.3 0.4 0 0.4 0.4 78 8 92 305 1 0 1 0 -14.4 0.3 -13.7 -14.6 04/02/2005 13:20:00 2.5 0.4 3.4 1.9 2.4 0.4 3.8 1.5 0.4 0 0.4 0.4 76 9 75 305 1 0 1 0 -13.6 0.1 -13.1 -14.1 04/02/2005 13:30:00 2.2 0.4 3 1.1 2.1 0.3 3 1.5 0.4 0 0.4 0.4 74 12 67 305 1 0 1 0 -13.6 0.5 -12.5 -14.4 04/02/2005 13:40:00 2.4 0.4 3.4 1.1 2.2 0.4 3 1.1 0.4 0 0.4 0.4 82 13 83 305 1 0 1 0 -13.5 0.5 -12.5 -14.4 04/02/2005 13:50:00 2.4 0.3 3 1.5 2.3 0.3 3 1.5 0.4 0 0.4 0.4 66 9 47 305 1 0 1 0 -14.6 0.5 -13.1 -15 04/02/2005 14:00:00 2.1 0.5 3 1.1 2 0.5 3 1.1 0.4 0 0.4 0.4 69 9 60 305 1 0 1 0 -14 0.2 -13.5 -14.6 04/02/2005 14:10:00 1.6 0.4 2.6 0.7 1.5 0.3 2.3 0.7 0.4 0 0.4 0.4 73 15 100 305 1 0 1 0 -13.4 0.6 -12.1 -14.4 04/02/2005 14:20:00 2.6 0.3 3.4 1.9 2.4 0.3 3 1.5 0.4 0 0.4 0.4 97 7 103 305 1 0 1 0 -11.9 0.4 -11.3 -12.9 04/02/2005 14:30:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 0.4 0 0.4 0.4 110 7 107 305 1 0 1 0 -11.5 0.1 -10.9 -11.7 04/02/2005 14:40:00 1.4 0.5 2.6 0.4 1.5 0.4 3 0.4 0.4 0 0.4 0.4 87 22 100 305 1 0 1 0 -11 0.3 -10.2 -11.5 04/02/2005 14:50:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0 0.4 0.4 97 66 238 305 1 0 1 0 -10.5 0.3 -9.8 -11.9 04/02/2005 15:00:00 1.7 0.6 3 0.4 2 0.6 3 0.4 0.4 0 0.4 0.4 163 17 147 305 1 0 1 0 -12.6 0.3 -11.9 -13.3 04/02/2005 15:10:00 2 0.5 3 0.4 2.2 0.5 3.4 1.1 0.4 0 0.4 0.4 146 24 138 305 0 0 0 0 -13.6 0.4 -12.9 -14.3 04/02/2005 15:20:00 1.6 0.7 3.4 0.4 1.6 0.7 3 0.4 0.4 0 0.4 0.4 131 38 123 305 0 0 0 0 -13.7 0.5 -12.9 -14.4 04/02/2005 15:30:00 1.9 0.5 3.4 0.7 2.4 0.5 3.8 0.7 0.4 0 0.4 0.4 161 17 135 305 0 0 0 0 -13.5 0.6 -12.7 -14.8 04/02/2005 15:40:00 2.1 0.5 3.4 0.7 2.6 0.4 3.4 1.5 0.4 0 0.4 0.4 156 9 153 305 0 0 0 0 -15.2 0.2 -14.8 -15.6 04/02/2005 15:50:00 1.6 0.9 3.8 0.4 1.9 0.8 3.8 0.4 0.4 0 0.4 0.4 194 38 155 305 0 0 0 0 -15.1 0.3 -14.6 -15.8 04/02/2005 16:00:00 3.2 0.5 4.2 1.9 3.2 0.4 4.2 1.9 0.4 0 0.4 0.4 217 9 211 305 0 0 0 0 -16.2 0.2 -15.8 -16.6 04/02/2005 16:10:00 2.2 0.8 4.2 0.4 2.4 0.7 4.2 0.7 0.4 0 0.4 0.4 196 27 216 305 0 0 0 0 -15.8 0.5 -14.6 -16.4 04/02/2005 16:20:00 2.1 0.8 3.8 0.4 2.4 0.6 3.8 0.7 0.4 0 0.4 0.4 163 28 186 305 0 0 0 0 -15.1 0.2 -14.6 -15.6 04/02/2005 16:30:00 2.3 0.6 3.8 0.7 2.6 0.6 4.2 1.5 0.4 0 0.4 0.4 164 27 141 305 0 0 0 0 -14.7 0.3 -14.3 -15.4 04/02/2005 16:40:00 2.8 0.7 4.2 0.7 3.2 0.6 4.6 1.5 0.4 0 0.4 0.4 141 12 142 305 0 0 0 0 -14.8 0.2 -14.4 -15.6 04/02/2005 16:50:00 2.4 1 4.9 0.4 2.7 0.9 4.9 0.7 0.4 0 0.4 0.4 171 33 213 305 0 0 0 0 -15.2 0.6 -14.3 -15.8 04/02/2005 17:00:00 2.6 1 4.6 0.7 2.9 0.9 4.9 1.1 0.4 0 0.4 0.4 182 17 188 305 0 0 0 0 -15.7 0.1 -15.2 -16 04/02/2005 17:10:00 2.8 0.8 4.6 1.1 3.1 0.8 4.9 1.5 0.4 0 0.4 0.4 157 23 192 305 0 0 0 0 -15.7 0.6 -14.6 -16.6 04/02/2005 17:20:00 3.2 0.6 4.6 1.5 3.7 0.6 4.9 2.3 0.4 0 0.4 0.4 143 8 140 305 0 0 0 0 -14.9 0.1 -14.6 -15.2 04/02/2005 17:30:00 2.7 0.7 4.2 0.7 3.2 0.7 4.6 1.1 0.4 0 0.4 0.4 133 17 110 305 0 0 0 0 -14.9 0.2 -14.3 -15 04/02/2005 17:40:00 2.9 1 4.6 0.7 3.2 0.8 4.6 1.1 0.4 0 0.4 0.4 137 15 142 305 0 0 0 0 -14.8 0.2 -14.3 -15.2 04/02/2005 17:50:00 2.6 1 4.9 0.7 3.1 0.9 4.9 1.1 0.4 0 0.4 0.4 132 15 134 305 0 0 0 0 -14.8 0.2 -14.4 -15 04/02/2005 18:00:00 2.6 0.7 4.2 1.1 3.2 0.7 4.6 1.5 0.4 0 0.4 0.4 150 19 164 305 0 0 0 0 -15.2 0.2 -14.8 -15.8 04/02/2005 18:10:00 3.8 0.7 4.9 1.5 4.3 0.8 5.3 1.1 0.4 0 0.4 0.4 138 9 139 305 0 0 0 0 -15.7 0 -15.6 -15.8 04/02/2005 18:20:00 3 0.7 4.6 0.7 3.7 0.7 5.3 2.3 0.4 0 0.4 0.4 135 15 138 305 0 0 0 0 -15.6 0.1 -15.2 -15.8 04/02/2005 18:30:00 2.9 0.8 4.6 0.7 3.5 0.8 4.9 1.9 0.4 0 0.4 0.4 148 12 151 305 0 0 0 0 -15.5 0.1 -15 -15.8 04/02/2005 18:40:00 3.4 0.8 4.9 1.5 3.9 0.7 5.3 1.9 0.4 0 0.4 0.4 138 11 162 305 0 0 0 0 -15.7 0.1 -15.2 -15.8 04/02/2005 18:50:00 2.5 0.8 4.2 0.7 3.1 0.6 4.9 1.5 0.4 0 0.4 0.4 138 15 143 305 0 0 0 0 -15.6 0 -15.2 -15.8 04/02/2005 19:00:00 2.1 0.6 3.4 0.4 2.5 0.6 3.8 1.1 0.4 0 0.4 0.4 133 11 136 305 0 0 0 0 -15.6 0.1 -15 -15.8 04/02/2005 19:10:00 1.5 0.5 2.6 0.4 2 0.5 3.4 1.1 0.4 0 0.4 0.4 146 9 145 305 0 0 0 0 -14.9 0.1 -14.4 -15.2 04/02/2005 19:20:00 1.6 0.5 2.6 0.4 2.1 0.4 3 1.1 0.4 0 0.4 0.4 156 15 124 305 0 0 0 0 -15.1 0 -14.8 -15.2 04/02/2005 19:30:00 3.4 0.6 5.3 2.3 3.9 0.5 5.3 2.6 0.4 0 0.4 0.4 138 8 138 305 0 0 0 0 -15.7 0.3 -15 -16.2 04/02/2005 19:40:00 3.9 0.6 4.9 1.9 4.5 0.4 5.3 2.6 0.4 0 0.4 0.4 137 8 133 305 0 0 0 0 -16.4 0 -16 -16.6 04/02/2005 19:50:00 3.6 0.7 4.9 1.9 4.1 0.6 5.3 2.6 0.4 0 0.4 0.4 142 9 129 305 0 0 0 0 -16.6 0.1 -16.4 -16.9 04/02/2005 20:00:00 3.3 0.7 4.9 1.5 3.8 0.7 5.7 2.3 0.4 0 0.4 0.4 134 11 144 305 0 0 0 0 -16.6 0 -16.4 -16.9 04/02/2005 20:10:00 2.3 0.9 4.6 0.4 3 0.9 5.3 1.5 0.4 0 0.4 0.4 136 14 128 305 0 0 0 0 -16.5 0.2 -16.2 -16.9 04/02/2005 20:20:00 3.2 0.7 4.6 1.5 3.6 0.6 4.9 1.5 0.4 0 0.4 0.4 127 13 130 305 0 0 0 0 -16.8 0 -16.6 -16.9 04/02/2005 20:30:00 3.6 0.5 4.9 2.3 3.8 0.5 4.9 2.3 0.4 0 0.4 0.4 131 12 145 305 0 0 0 0 -17.1 0 -16.9 -17.3 04/02/2005 20:40:00 4.4 0.5 5.3 2.3 4.7 0.4 5.7 3 0.4 0 0.4 0.4 133 7 138 305 0 0 0 0 -17.5 0.1 -16.9 -17.9 04/02/2005 20:50:00 4.7 0.7 6.1 2.3 5.1 0.6 6.5 3 0.4 0 0.4 0.4 137 11 131 305 0 0 0 0 -18 0.1 -17.7 -18.4 04/02/2005 21:00:00 5.3 0.9 7.2 2.6 5.5 0.9 6.8 2.6 0.4 0 0.4 0.4 135 9 153 305 0 0 0 0 -18.6 0.1 -18.1 -18.8 04/02/2005 21:10:00 4.4 1.1 6.5 1.9 5 0.9 6.8 2.6 0.4 0 0.4 0.4 132 12 132 305 0 0 0 0 -18.7 0 -18.4 -19 04/02/2005 21:20:00 4.8 1 6.8 2.3 5.3 1 6.8 2.3 0.4 0 0.4 0.4 136 10 135 305 0 0 0 0 -18.7 0.1 -18.4 -19 04/02/2005 21:30:00 4.3 1 6.1 1.9 4.9 0.9 6.8 2.6 0.4 0 0.4 0.4 136 10 143 305 0 0 0 0 -18.8 0 -18.2 -19 04/02/2005 21:40:00 5.9 0.8 7.2 3.4 6.3 0.6 7.6 4.2 0.4 0 0.4 0.4 129 6 128 305 1 0 0 0 -18.9 0 -18.4 -19 04/02/2005 21:50:00 6.7 0.6 8 4.9 6.7 0.6 8 5.3 0.4 0 0.4 0.4 127 4 127 305 1 0 1 0 -18.8 0 -18.6 -19 04/02/2005 22:00:00 6.8 0.7 8.8 5.3 6.8 0.7 9.1 5.7 0.4 0 0.4 0.4 123 6 119 305 1 0 1 0 -18.8 0 -18.6 -19 04/02/2005 22:10:00 6.7 1 8.4 4.2 6.5 1 8 4.2 0.4 0 0.4 0.4 113 4 108 305 1 0 1 0 -18.8 0 -18.6 -19 04/02/2005 22:20:00 6.4 0.5 7.6 4.6 6.2 0.5 7.6 4.9 0.4 0 0.4 0.4 109 5 110 305 1 0 1 0 -18.7 0 -18.4 -19 04/02/2005 22:30:00 5.3 0.4 6.5 4.2 5.2 0.4 6.1 4.2 0.4 0 0.4 0.4 107 4 105 305 1 0 1 0 -19 0.1 -18.6 -19.2 04/02/2005 22:40:00 4.5 0.6 5.7 3 4.3 0.5 5.7 3 0.4 0 0.4 0.4 99 6 98 305 1 0 1 0 -19.2 0 -19 -19.5 04/02/2005 22:50:00 4.3 0.4 5.7 3 4.1 0.4 4.9 3.4 0.4 0 0.4 0.4 89 11 42 305 1 0 1 0 -19.4 0 -19.2 -19.5 04/02/2005 23:00:00 4.7 0.8 6.5 2.6 4.5 0.7 6.5 3 0.4 0 0.4 0.4 73 11 69 305 1 0 1 0 -19.1 0.1 -18.8 -19.5 04/02/2005 23:10:00 4 0.5 5.3 2.6 4 0.5 5.3 3 0.4 0 0.4 0.4 54 11 54 305 1 0 1 0 -18.7 0 -18.4 -19 04/02/2005 23:20:00 6.5 0.7 8 3.8 6.4 0.8 8 3.4 0.4 0 0.4 0.4 29 6 20 305 1 0 1 0 -18.5 0.1 -18.2 -18.8 04/02/2005 23:30:00 7 0.5 8.4 5.7 7 0.5 8.4 5.7 0.4 0 0.4 0.4 32 5 34 305 2 0 2 0 -18.5 0 -18.2 -18.8 04/02/2005 23:40:00 7.2 0.6 8.8 5.3 7.2 0.6 8.8 5.3 0.4 0 0.4 0.4 32 4 29 305 2 0 2 0 -18.7 0 -18.4 -19 04/02/2005 23:50:00 7.8 0.6 9.1 6.1 7.7 0.6 9.5 6.1 0.4 0 0.4 0.4 32 4 33 305 2 0 2 0 -18.8 0 -18.6 -19 04/03/2005 00:00:00 8 0.6 9.5 6.5 8 0.7 9.9 6.5 0.4 0 0.4 0.4 34 5 36 305 2 0 2 0 -18.9 0.1 -18.2 -19 04/03/2005 00:10:00 8.2 0.5 9.5 6.8 8.2 0.6 9.9 7.2 0.4 0 0.4 0.4 33 4 40 305 2 0 1 0 -19 0 -18.4 -19.2 04/03/2005 00:20:00 8.1 0.6 9.9 6.5 8.2 0.7 9.5 6.1 0.4 0 0.4 0.4 34 4 35 305 2 0 2 0 -19.2 0 -18.4 -19.3 04/03/2005 00:30:00 8.6 0.7 9.9 6.8 8.7 0.8 10.3 6.8 0.4 0 0.4 0.4 32 5 33 305 2 0 2 0 -19.3 0.1 -19 -19.5 04/03/2005 00:40:00 8.3 0.6 9.9 6.8 8.2 0.7 9.9 6.1 0.4 0 0.4 0.4 34 5 33 305 2 0 2 0 -19.7 0 -19 -19.9 04/03/2005 00:50:00 7.1 0.5 8.8 5.7 7 0.6 8.8 5.3 0.4 0 0.4 0.4 34 5 31 305 2 0 2 0 -19.7 0 -19 -19.9 04/03/2005 01:00:00 6.3 0.6 8 4.9 6.3 0.6 8 5.3 0.4 0 0.4 0.4 29 4 32 305 2 0 2 0 -19.6 0 -19 -19.7 04/03/2005 01:10:00 7.1 0.7 9.1 5.3 7.1 0.6 8.4 5.3 0.4 0 0.4 0.4 23 5 19 305 2 0 1 0 -19.7 0 -19.2 -19.9 04/03/2005 01:20:00 7.5 0.6 8.8 5.7 7.4 0.6 8.8 5.3 0.4 0 0.4 0.4 22 4 20 305 2 0 1 0 -19.8 0 -19.3 -20.1 04/03/2005 01:30:00 6.9 0.6 8.4 5.7 6.8 0.5 8.4 5.7 0.4 0 0.4 0.4 25 5 22 305 1 0 1 0 -20.1 0.1 -19.5 -20.1 04/03/2005 01:40:00 6.9 0.5 8 5.3 6.8 0.6 8.4 5.3 0.4 0 0.4 0.4 21 4 24 305 1 0 1 0 -20.2 0 -19.5 -20.4 04/03/2005 01:50:00 6.9 0.6 8.4 5.7 6.8 0.6 8.8 5.3 0.4 0 0.4 0.4 20 4 17 305 1 0 2 0 -20.3 0.1 -19.7 -20.6 04/03/2005 02:00:00 6.5 0.6 8 4.9 6.5 0.6 7.6 4.9 0.4 0 0.4 0.4 20 5 17 305 1 0 1 0 -20.5 0 -20.1 -20.8 04/03/2005 02:10:00 6 0.5 7.6 4.6 6 0.5 7.2 4.9 0.4 0 0.4 0.4 21 5 14 305 1 0 1 0 -20.6 0.1 -20.1 -20.8 04/03/2005 02:20:00 5.8 0.6 7.6 4.2 5.7 0.5 7.2 4.6 0.4 0 0.4 0.4 21 4 17 305 1 0 2 0 -20.6 0.1 -20.1 -20.8 04/03/2005 02:30:00 6.2 0.6 7.6 4.6 6.1 0.6 7.2 4.6 0.4 0 0.4 0.4 22 4 23 305 1 0 1 0 -20.6 0.1 -20.1 -20.8 04/03/2005 02:40:00 6.4 0.6 8.4 4.9 6.3 0.6 8.4 4.9 0.4 0 0.4 0.4 17 5 18 305 2 0 2 0 -20.5 0 -20.1 -20.8 04/03/2005 02:50:00 6.3 0.6 8.4 4.9 6.2 0.6 8 4.9 0.4 0 0.4 0.4 16 5 11 305 2 0 2 0 -20.3 0 -19.9 -20.6 04/03/2005 03:00:00 6.9 0.7 9.1 5.3 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 13 5 8 305 2 0 2 0 -20.3 0 -20.1 -20.4 04/03/2005 03:10:00 6.8 0.7 8.4 5.3 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 12 5 12 305 2 0 2 0 -20.3 0 -20.1 -20.4 04/03/2005 03:20:00 7.3 0.7 9.1 5.3 7.2 0.7 9.1 5.3 0.4 0 0.4 0.4 12 6 19 305 2 0 1 0 -20.2 0 -20.1 -20.6 04/03/2005 03:30:00 7.1 0.5 8.4 5.7 7 0.5 8.8 5.7 0.4 0 0.4 0.4 10 4 11 305 2 0 2 0 -20.2 0 -20.1 -20.2 04/03/2005 03:40:00 7.3 0.7 9.1 5.7 7.1 0.7 9.5 5.3 0.4 0 0.4 0.4 11 5 15 305 2 0 2 0 -20.1 0 -19.5 -20.1 04/03/2005 03:50:00 7.8 0.6 9.1 6.1 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 9 4 8 305 2 0 2 0 -19.9 0 -19.7 -20.1 04/03/2005 04:00:00 6.9 0.6 8.8 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 10 5 10 305 2 0 2 0 -19.8 0 -19.5 -20.1 04/03/2005 04:10:00 7.3 0.7 8.8 5.3 7.3 0.7 9.5 5.3 0.4 0 0.4 0.4 8 5 12 305 2 0 2 0 -19.9 0 -19.3 -20.1 04/03/2005 04:20:00 7.9 0.7 10.3 6.5 7.9 0.8 10.3 5.3 0.4 0 0.4 0.4 7 5 0 305 2 0 2 0 -20 0.1 -19.3 -20.1 04/03/2005 04:30:00 8.6 0.7 10.7 6.8 8.6 0.8 10.7 6.5 0.4 0 0.4 0.4 5 5 4 305 2 0 2 0 -20.2 0 -19.5 -20.4 04/03/2005 04:40:00 8.5 0.8 10.7 6.5 8.4 0.8 11.1 6.5 0.4 0 0.4 0.4 6 7 0 305 2 0 2 0 -20.3 0.1 -19.9 -20.6 04/03/2005 04:50:00 9.4 0.8 11.5 6.8 9.4 0.9 11.8 6.8 0.4 0 0.4 0.4 11 5 9 305 2 0 2 0 -20.4 0 -19.9 -20.6 04/03/2005 05:00:00 9.6 0.7 11.1 7.2 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 13 6 21 305 2 0 2 0 -20.5 0 -20.1 -20.6 04/03/2005 05:10:00 8.4 0.8 10.3 6.1 8.3 0.8 9.9 6.1 0.4 0 0.4 0.4 13 4 23 305 2 0 2 0 -20.4 0 -19.9 -20.6 04/03/2005 05:20:00 8.3 1.1 10.7 5.7 8.2 1.1 10.7 5.7 0.4 0 0.4 0.4 11 5 17 305 2 0 2 0 -20.5 0 -20.1 -20.8 04/03/2005 05:30:00 7.6 0.7 9.5 5.7 7.6 0.7 9.5 6.1 0.4 0 0.4 0.4 13 5 12 305 2 0 2 0 -20.5 0 -20.2 -20.6 04/03/2005 05:40:00 8.1 0.7 9.5 6.1 8 0.7 9.9 6.1 0.4 0 0.4 0.4 11 4 14 305 2 0 1 0 -20.3 0 -20.1 -20.6 04/03/2005 05:50:00 7.4 0.6 8.4 5.7 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 9 5 16 305 1 0 1 0 -20.4 0 -20.2 -20.6 04/03/2005 06:00:00 7.2 0.7 9.1 5.3 7.2 0.7 9.1 5.7 0.4 0 0.4 0.4 11 5 21 305 1 0 1 0 -20.4 0 -19.9 -20.6 04/03/2005 06:10:00 7.7 0.7 9.1 5.7 7.6 0.7 9.1 6.1 0.4 0 0.4 0.4 12 5 14 305 1 0 1 0 -20.3 0 -19.9 -20.4 04/03/2005 06:20:00 7.1 0.7 8.8 5.3 7 0.7 8.8 5.3 0.4 0 0.4 0.4 12 5 4 305 2 0 1 0 -20.2 0 -20.1 -20.4 04/03/2005 06:30:00 8 0.7 9.5 6.5 8 0.7 9.5 6.1 0.4 0 0.4 0.4 11 4 1 305 2 0 1 0 -20.1 0 -19.9 -20.2 04/03/2005 06:40:00 7.7 0.6 9.1 6.1 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 11 5 14 305 2 0 2 0 -20.1 0 -19.9 -20.1 04/03/2005 06:50:00 7.5 0.7 9.1 5.7 7.4 0.8 9.5 5.3 0.4 0 0.4 0.4 11 4 11 305 2 0 1 0 -20.1 0 -19.9 -20.1 04/03/2005 07:00:00 7.1 0.7 9.1 5.7 7 0.7 9.1 5.3 0.4 0 0.4 0.4 10 5 11 305 2 0 2 0 -20.2 0 -19.9 -20.1 04/03/2005 07:10:00 6.6 0.6 8 5.3 6.6 0.6 8.4 4.9 0.4 0 0.4 0.4 9 4 9 305 2 0 2 0 -20.2 0 -19.9 -20.2 04/03/2005 07:20:00 6.5 0.6 8.4 4.6 6.4 0.6 7.6 4.6 0.4 0 0.4 0.4 6 5 8 305 2 0 1 0 -20.2 0 -20.1 -20.1 04/03/2005 07:30:00 7.1 0.7 8.8 5.3 7.1 0.8 8.8 5.3 0.4 0 0.4 0.4 3 4 1 305 2 0 2 0 -20.2 0 -20.1 -20.2 04/03/2005 07:40:00 6.8 0.6 8.4 5.3 6.8 0.6 8.8 4.9 0.4 0 0.4 0.4 358 4 0 305 2 0 2 0 -20.2 0 -19.7 -20.2 04/03/2005 07:50:00 6.5 0.5 8.4 4.9 6.4 0.6 8.4 4.6 0.4 0 0.4 0.4 359 4 0 305 2 0 1 0 -20.2 0 -20.1 -20.4 04/03/2005 08:00:00 6.3 0.6 7.6 4.6 6.3 0.6 8.4 4.6 0.4 0 0.4 0.4 359 4 357 305 2 0 2 0 -20.2 0 -19.9 -20.2 04/03/2005 08:10:00 5.9 0.5 7.6 4.6 5.8 0.6 7.6 4.2 0.4 0 0.4 0.4 1 5 0 305 2 0 2 0 -20.2 0 -20.1 -20.2 04/03/2005 08:20:00 6.7 0.8 8.8 4.9 6.6 0.9 8.4 4.9 0.4 0 0.4 0.4 2 5 0 305 2 0 2 0 -20.2 0 -19.5 -20.1 04/03/2005 08:30:00 7 0.6 8.8 5.7 6.9 0.7 8.4 5.7 0.4 0 0.4 0.4 0 5 355 305 2 0 2 0 -20 0 -19.5 -20.1 04/03/2005 08:40:00 6.7 0.6 8.8 5.3 6.5 0.6 8.4 4.6 0.4 0 0.4 0.4 2 5 3 305 2 0 2 0 -19.9 0 -19.5 -20.1 04/03/2005 08:50:00 6.9 0.6 8.4 5.3 6.8 0.6 8 5.3 0.4 0 0.4 0.4 2 4 5 305 2 0 2 0 -19.9 0 -19.5 -20.1 04/03/2005 09:00:00 6.4 0.5 8 5.3 6.3 0.5 8 4.9 0.4 0 0.4 0.4 0 4 0 305 2 0 2 0 -19.7 0 -19.2 -20.1 04/03/2005 09:10:00 6.5 0.7 8.8 4.9 6.4 0.7 8.4 4.6 0.4 0 0.4 0.4 358 5 0 305 2 0 2 0 -19.7 0 -19.5 -19.9 04/03/2005 09:20:00 7 0.7 8.8 4.9 7 0.7 9.1 5.3 0.4 0 0.4 0.4 354 5 5 305 2 0 2 0 -19.4 0.1 -19.2 -19.5 04/03/2005 09:30:00 6.4 0.7 8.8 4.9 6.4 0.6 8.8 5.3 0.4 0 0.4 0.4 6 9 357 305 2 0 2 0 -19 0.1 -18.6 -19.3 04/03/2005 09:40:00 5.2 0.5 6.5 4.2 5.1 0.5 6.5 4.2 0.4 0 0.4 0.4 24 5 18 305 2 0 2 0 -18.8 0 -18.4 -19 04/03/2005 09:50:00 5 0.5 6.1 3.8 4.9 0.5 6.5 3.8 0.4 0 0.4 0.4 25 4 22 305 2 0 2 0 -18.7 0 -18.4 -18.8 04/03/2005 10:00:00 4.7 0.5 5.7 3.4 4.6 0.5 5.7 3.4 0.4 0 0.4 0.4 30 5 37 305 2 0 2 0 -18.7 0 -18.4 -18.8 04/03/2005 10:10:00 4.8 0.5 5.7 3.4 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 26 4 27 305 2 0 2 0 -18.6 0.1 -18.2 -18.8 04/03/2005 10:20:00 4.3 0.5 5.7 3.4 4.4 0.5 5.7 3.4 0.4 0 0.4 0.4 19 5 25 305 1 0 2 0 -18.4 0.1 -18.1 -18.6 04/03/2005 10:30:00 4.3 0.4 5.3 3.4 4.4 0.4 5.7 3.4 0.4 0 0.4 0.4 21 5 19 305 1 0 1 0 -18.4 0.1 -18.1 -18.4 04/03/2005 10:40:00 4.5 0.5 6.1 3.4 4.5 0.4 6.1 3.4 0.4 0 0.4 0.4 20 6 8 305 1 0 1 0 -18.3 0.1 -17.9 -18.4 04/03/2005 10:50:00 5.6 0.8 7.6 3.8 5.7 0.8 7.6 4.2 0.4 0 0.4 0.4 4 8 8 305 1 0 1 0 -18.1 0 -17.9 -18.4 04/03/2005 11:00:00 5.1 0.7 6.8 3.4 5.2 0.7 6.8 3.4 0.4 0 0.4 0.4 12 4 11 305 1 0 1 0 -18.1 0 -17.9 -18.4 04/03/2005 11:10:00 4.5 0.4 5.7 3.4 4.6 0.4 5.7 3.4 0.4 0 0.4 0.4 10 5 8 305 1 0 1 0 -18 0 -17.7 -18.1 04/03/2005 11:20:00 4.2 0.5 5.3 3 4.3 0.5 5.3 3 0.4 0 0.4 0.4 14 4 14 305 1 0 1 0 -17.9 0.1 -17.5 -18.1 04/03/2005 11:30:00 5.1 0.6 6.8 3.8 5.2 0.7 6.8 3.8 0.4 0 0.4 0.4 9 5 8 305 1 0 1 0 -17.8 0.1 -17.5 -18.1 04/03/2005 11:40:00 6 0.8 8.4 3.8 6.1 0.8 8 4.6 0.4 0 0.4 0.4 3 6 358 305 1 0 1 0 -17.8 0.1 -17.3 -18.1 04/03/2005 11:50:00 7.7 0.8 9.5 5.7 7.7 0.8 9.9 5.3 0.4 0 0.4 0.4 359 5 358 305 1 0 1 0 -17.9 0.1 -17.5 -18.1 04/03/2005 12:00:00 8.2 0.6 9.5 6.8 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 357 4 352 305 1 0 0 0 -17.9 0.1 -17.5 -18.1 04/03/2005 12:10:00 7.7 0.7 9.9 6.1 7.8 0.8 9.9 6.1 0.4 0 0.4 0.4 357 4 356 305 1 0 1 0 -17.8 0 -17.5 -18.1 04/03/2005 12:20:00 7.4 0.9 9.9 5.3 7.5 0.9 9.9 5.3 0.4 0 0.4 0.4 354 5 357 305 1 0 0 0 -17.7 0 -17.5 -17.9 04/03/2005 12:30:00 7.5 0.7 9.1 5.3 7.5 0.8 9.5 5.7 0.4 0 0.4 0.4 352 5 348 305 1 0 1 0 -17.6 0 -17.5 -17.9 04/03/2005 12:40:00 7.7 0.7 9.1 5.7 7.8 0.7 9.1 5.7 0.4 0 0.4 0.4 352 4 357 305 1 0 1 0 -17.7 0.1 -17.3 -18.1 04/03/2005 12:50:00 7.3 0.7 9.1 5.3 7.3 0.7 9.1 5.3 0.4 0 0.4 0.4 357 4 354 305 1 0 1 0 -17.5 0 -17.1 -17.7 04/03/2005 13:00:00 7 0.7 9.1 4.9 7.1 0.7 8.8 5.3 0.4 0 0.4 0.4 356 5 356 305 1 0 1 0 -17.3 0 -16.9 -17.5 04/03/2005 13:10:00 6.9 0.7 8.4 5.3 7 0.7 8.8 5.3 0.4 0 0.4 0.4 354 5 353 305 1 0 1 0 -17 0 -16.7 -17.3 04/03/2005 13:20:00 6.4 0.9 8.8 4.6 6.4 1 8.8 4.6 0.4 0 0.4 0.4 358 5 2 305 1 0 0 0 -16.9 0 -16.6 -17.1 04/03/2005 13:30:00 7.1 0.7 8.8 4.9 7 0.7 9.1 4.9 0.4 0 0.4 0.4 1 5 359 305 1 0 1 0 -16.9 0 -16.4 -16.9 04/03/2005 13:40:00 7.1 0.8 9.1 4.9 7.2 0.9 9.1 4.9 0.4 0 0.4 0.4 358 6 353 305 0 0 0 0 -16.9 0 -16.6 -17.3 04/03/2005 13:50:00 6.7 0.8 8.8 4.9 6.7 0.8 8.4 4.9 0.4 0 0.4 0.4 0 5 358 305 1 0 1 0 -16.8 0.1 -16.4 -16.9 04/03/2005 14:00:00 7.4 0.7 8.8 5.7 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 1 5 359 305 0 0 0 0 -16.7 0.1 -16.2 -16.9 04/03/2005 14:10:00 6.9 0.7 8.8 5.3 6.9 0.8 9.1 4.6 0.4 0 0.4 0.4 359 6 2 305 1 0 0 0 -16.2 0.1 -15.8 -16.4 04/03/2005 14:20:00 7.4 0.8 9.1 5.3 7.5 0.8 9.9 5.3 0.4 0 0.4 0.4 357 5 350 305 1 0 1 0 -15.9 0.1 -15.6 -16.2 04/03/2005 14:30:00 7.7 1 10.3 5.3 7.8 1 10.7 5.3 0.4 0 0.4 0.4 356 6 355 305 1 0 1 0 -15.6 0.1 -15 -15.8 04/03/2005 14:40:00 9.1 0.9 11.1 6.5 9.3 0.9 11.5 6.8 0.4 0 0.4 0.4 357 3 353 305 1 0 1 0 -15.7 0.1 -15.2 -15.8 04/03/2005 14:50:00 8.2 1 10.3 5.7 8.2 1 10.7 6.1 0.4 0 0.4 0.4 4 6 10 305 1 0 1 0 -15.5 0.1 -14.8 -15.8 04/03/2005 15:00:00 8.5 0.7 9.9 6.5 8.4 0.7 10.3 6.8 0.4 0 0.4 0.4 8 5 12 305 1 0 1 0 -15.6 0.2 -15 -16 04/03/2005 15:10:00 7.4 0.8 9.5 5.3 7.4 0.8 9.1 5.7 0.4 0 0.4 0.4 4 7 0 305 1 0 1 0 -15.5 0.2 -15 -15.8 04/03/2005 15:20:00 7.5 0.6 8.8 5.7 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 2 5 4 305 1 0 0 0 -15.4 0.1 -14.8 -15.6 04/03/2005 15:30:00 7.5 0.8 9.1 5.7 7.7 0.7 9.5 5.7 0.4 0 0.4 0.4 358 5 356 305 1 0 1 0 -15.3 0 -14.8 -15.6 04/03/2005 15:40:00 7.8 0.7 9.5 5.7 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 359 4 359 305 1 0 1 0 -15.1 0.1 -14.6 -15.2 04/03/2005 15:50:00 7.4 0.6 8.8 6.1 7.6 0.7 8.8 6.1 0.4 0 0.4 0.4 357 5 0 305 1 0 1 0 -15.2 0.1 -14.6 -15.4 04/03/2005 16:00:00 7.8 0.8 9.5 6.1 7.9 0.8 9.5 6.1 0.4 0 0.4 0.4 353 5 357 305 1 0 0 0 -15.2 0.1 -14.6 -15.4 04/03/2005 16:10:00 7.7 0.7 9.1 5.7 7.8 0.7 9.1 6.1 0.4 0 0.4 0.4 351 5 353 305 1 0 0 0 -15.2 0.1 -14.6 -15.2 04/03/2005 16:20:00 7.3 0.7 9.1 5.3 7.4 0.7 8.8 5.7 0.4 0 0.4 0.4 351 5 357 305 0 0 0 0 -15.1 0.1 -14.6 -15.4 04/03/2005 16:30:00 7.1 0.6 8.8 5.3 7.2 0.7 9.1 5.7 0.4 0 0.4 0.4 8 6 359 305 0 0 1 0 -15.4 0.2 -14.6 -15.8 04/03/2005 16:40:00 6.7 0.5 8.4 5.3 6.7 0.6 8.4 5.3 0.4 0 0.4 0.4 11 5 12 305 1 0 0 0 -15.3 0.1 -14.6 -15.6 04/03/2005 16:50:00 6.9 1 9.1 4.9 6.9 1 9.1 4.6 0.4 0 0.4 0.4 6 6 9 305 0 0 0 0 -15.1 0.1 -14.6 -15.2 04/03/2005 17:00:00 6.8 0.6 8 5.3 6.9 0.7 8.4 5.3 0.4 0 0.4 0.4 8 6 10 305 0 0 0 0 -15.2 0.1 -14.6 -15.4 04/03/2005 17:10:00 7.4 0.8 9.1 5.7 7.5 0.8 9.1 5.7 0.4 0 0.4 0.4 6 5 2 305 0 0 1 0 -14.9 0.2 -14.3 -15.2 04/03/2005 17:20:00 7.5 0.6 8.8 5.7 7.5 0.6 8.8 6.1 0.4 0 0.4 0.4 6 5 4 305 1 0 0 0 -14.7 0.1 -14.4 -15 04/03/2005 17:30:00 7 0.6 8.4 5.3 7.1 0.6 8.8 5.3 0.4 0 0.4 0.4 4 5 16 305 0 0 0 0 -14.8 0 -14.6 -15 04/03/2005 17:40:00 7.1 0.6 8.8 5.7 7.1 0.6 9.1 5.3 0.4 0 0.4 0.4 4 5 7 305 0 0 0 0 -15.1 0.1 -14.6 -15.2 04/03/2005 17:50:00 7.3 0.6 8.8 5.7 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 359 5 1 305 0 0 0 0 -14.8 0.1 -14.3 -15 04/03/2005 18:00:00 7.6 0.9 9.5 5.7 7.7 1 10.3 5.7 0.4 0 0.4 0.4 356 5 0 305 1 0 1 0 -14.5 0.1 -14.1 -14.6 04/03/2005 18:10:00 6.6 0.7 8.4 4.6 6.6 0.7 8.4 4.9 0.4 0 0.4 0.4 353 5 352 305 1 0 1 0 -14.4 0.1 -14.1 -14.6 04/03/2005 18:20:00 7.4 0.8 9.1 5.3 7.4 0.8 9.5 5.7 0.4 0 0.4 0.4 353 6 357 305 1 0 1 0 -14.2 0 -13.7 -14.4 04/03/2005 18:30:00 7.1 0.9 9.1 4.9 7.1 0.9 9.1 4.9 0.4 0 0.4 0.4 354 6 355 305 1 0 1 0 -14.3 0.1 -13.7 -14.6 04/03/2005 18:40:00 7.2 0.8 8.8 4.6 7.1 0.9 9.1 4.9 0.4 0 0.4 0.4 0 5 358 305 1 0 0 0 -14.6 0.1 -14.3 -14.8 04/03/2005 18:50:00 7.5 0.9 9.5 5.3 7.3 0.9 9.5 5.7 0.4 0 0.4 0.4 359 5 356 305 1 0 0 0 -14.5 0.1 -14.3 -14.8 04/03/2005 19:00:00 7.5 0.9 9.5 5.7 7.4 0.8 9.5 5.7 0.4 0 0.4 0.4 0 5 4 305 1 0 0 0 -14.4 0.2 -14.1 -14.8 04/03/2005 19:10:00 6.9 0.8 8.8 4.9 6.8 0.7 8.8 4.9 0.4 0 0.4 0.4 357 5 356 305 1 0 1 0 -14.2 0 -13.9 -14.4 04/03/2005 19:20:00 6.9 0.6 8.4 5.3 6.9 0.6 8.4 5.7 0.4 0 0.4 0.4 355 4 355 305 1 0 1 0 -14.1 0.1 -13.7 -14.3 04/03/2005 19:30:00 7.7 1 10.7 5.7 7.7 0.9 10.7 6.1 0.4 0 0.4 0.4 359 5 355 305 1 0 1 0 -14.1 0.1 -13.7 -14.3 04/03/2005 19:40:00 7.5 0.7 9.5 5.7 7.5 0.7 9.1 6.1 0.4 0 0.4 0.4 2 5 4 305 1 0 1 0 -14.2 0 -13.7 -14.3 04/03/2005 19:50:00 7.4 0.8 9.1 5.7 7.3 0.7 9.1 5.3 0.4 0 0.4 0.4 355 5 346 305 1 0 1 0 -14.2 0 -13.9 -14.4 04/03/2005 20:00:00 7.3 0.9 9.5 5.3 7.2 0.8 9.1 5.3 0.4 0 0.4 0.4 3 5 356 305 1 0 1 0 -14.1 0 -13.7 -14.3 04/03/2005 20:10:00 8.2 1 10.7 5.7 8.1 1.1 10.3 4.9 0.4 0 0.4 0.4 8 6 359 305 1 0 1 0 -14.2 0 -13.9 -14.3 04/03/2005 20:20:00 6.7 1.2 9.1 3.8 6.6 1.2 9.9 3.8 0.4 0 0.4 0.4 4 7 13 305 1 0 1 0 -14.2 0 -13.9 -14.4 04/03/2005 20:30:00 5.9 0.7 7.6 3.8 5.8 0.7 8 3.8 0.4 0 0.4 0.4 2 6 358 305 1 0 1 0 -14.3 0 -14.1 -14.4 04/03/2005 20:40:00 6.1 0.5 7.2 4.6 6 0.5 7.2 4.6 0.4 0 0.4 0.4 8 4 2 305 1 0 1 0 -14.4 0.1 -14.3 -14.6 04/03/2005 20:50:00 5.7 0.6 8 4.6 5.5 0.6 7.6 4.2 0.4 0 0.4 0.4 5 5 7 305 1 0 1 0 -14.7 0 -14.3 -14.8 04/03/2005 21:00:00 5.7 0.4 7.2 4.6 5.5 0.4 6.5 4.6 0.4 0 0.4 0.4 2 5 6 305 1 0 1 0 -14.7 0 -14.4 -15 04/03/2005 21:10:00 5.3 0.6 6.8 4.2 5.2 0.6 6.5 3.4 0.4 0 0.4 0.4 356 5 354 305 1 0 1 0 -14.9 0.1 -14.6 -15 04/03/2005 21:20:00 4.9 0.6 6.1 3.4 4.7 0.5 6.1 3.4 0.4 0 0.4 0.4 8 4 2 305 1 0 1 0 -15.2 0 -14.8 -15.4 04/03/2005 21:30:00 5.4 0.4 6.1 4.2 5 0.4 6.1 3.8 0.4 0 0.4 0.4 4 4 7 305 1 0 1 0 -15.4 0 -15.2 -15.6 04/03/2005 21:40:00 4.6 0.5 6.1 3.4 4.4 0.4 5.7 3.4 0.4 0 0.4 0.4 356 5 355 305 1 0 1 0 -15.5 0 -15.2 -15.6 04/03/2005 21:50:00 4.9 0.4 6.1 3.8 4.7 0.4 5.7 3.8 0.4 0 0.4 0.4 357 3 356 305 1 0 1 0 -15.5 0 -15.2 -15.6 04/03/2005 22:00:00 4.6 0.4 5.3 3.4 4.4 0.4 5.3 3.4 0.4 0 0.4 0.4 8 3 3 305 1 0 1 0 -15.6 0.1 -15.2 -15.8 04/03/2005 22:10:00 4.4 0.4 5.7 3.4 4.2 0.4 5.3 3.4 0.4 0 0.4 0.4 6 5 357 305 2 0 1 0 -15.7 0 -15.6 -15.8 04/03/2005 22:20:00 5.4 0.5 6.8 4.2 5.1 0.5 6.5 3.8 0.4 0 0.4 0.4 5 6 14 305 2 0 2 0 -15.7 0.1 -15.2 -15.8 04/03/2005 22:30:00 4.8 0.8 6.8 3 4.5 0.8 6.5 2.3 0.4 0 0.4 0.4 14 7 9 305 2 0 2 0 -15.7 0.1 -15.4 -15.8 04/03/2005 22:40:00 2.8 0.7 4.6 1.1 2.7 0.5 4.2 1.5 0.4 0 0.4 0.4 12 9 5 305 2 0 2 0 -15.9 0 -15.6 -16 04/03/2005 22:50:00 3.5 0.7 4.9 1.5 3.3 0.7 4.9 1.5 0.4 0 0.4 0.4 17 7 31 305 2 0 2 0 -15.8 0 -15.6 -16 04/03/2005 23:00:00 3.5 0.7 5.7 1.9 3.6 0.7 5.7 1.9 0.4 0 0.4 0.4 30 11 18 305 2 0 2 0 -15.6 0.1 -15.2 -15.8 04/03/2005 23:10:00 4.8 0.9 6.5 2.6 4.6 0.8 6.1 2.6 0.4 0 0.4 0.4 15 5 12 305 2 0 2 0 -15.8 0 -15.4 -16 04/03/2005 23:20:00 3.8 0.7 5.7 2.6 3.8 0.6 5.3 2.6 0.4 0 0.4 0.4 7 4 8 305 2 0 2 0 -15.7 0 -15.6 -15.8 04/03/2005 23:30:00 4.7 0.7 6.5 3 4.4 0.6 5.7 3 0.4 0 0.4 0.4 12 2 9 305 2 0 2 0 -15.9 0.1 -15.6 -16.2 04/03/2005 23:40:00 4.8 0.7 6.5 3 4.6 0.6 6.5 3 0.4 0 0.4 0.4 9 3 7 305 2 0 2 0 -16.1 0 -16 -16.4 04/03/2005 23:50:00 2.5 0.6 3.8 1.5 2.6 0.5 3.8 1.5 0.4 0 0.4 0.4 16 7 10 305 2 0 2 0 -16.1 0.1 -15.8 -16.4 04/04/2005 00:00:00 2.4 0.5 3.4 1.1 2.5 0.4 3.8 1.5 0.4 0 0.4 0.4 27 9 31 305 2 0 2 0 -15.7 0.1 -15.4 -16 04/04/2005 00:10:00 2.5 0.5 3.8 1.5 2.6 0.4 3.8 1.5 0.4 0 0.4 0.4 22 9 14 305 2 0 2 0 -15.8 0 -15.6 -16 04/04/2005 00:20:00 2.9 0.6 4.2 1.5 2.9 0.5 3.8 1.5 0.4 0 0.4 0.4 26 6 18 305 2 0 2 0 -15.8 0 -15.6 -16 04/04/2005 00:30:00 3 0.3 4.2 2.3 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 25 6 14 305 2 0 2 0 -15.5 0 -15.2 -15.8 04/04/2005 00:40:00 2.8 0.5 3.8 1.5 2.8 0.5 3.8 1.9 0.4 0 0.4 0.4 15 6 13 305 2 0 2 0 -15.5 0 -15.2 -15.6 04/04/2005 00:50:00 2.5 0.2 3 1.5 2.8 0.3 3.4 1.9 0.4 0 0.4 0.4 13 9 36 305 2 0 2 0 -15.4 0 -15 -15.6 04/04/2005 01:00:00 3 0.4 3.8 2.3 3 0.4 4.2 2.3 0.4 0 0.4 0.4 13 4 15 305 2 0 2 0 -15.3 0 -15 -15.6 04/04/2005 01:10:00 3.4 0.4 4.9 2.3 3.4 0.4 4.6 2.3 0.4 0 0.4 0.4 13 4 11 305 2 0 2 0 -15.6 0 -15.4 -15.8 04/04/2005 01:20:00 2.8 0.3 3.4 1.9 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 14 4 19 305 2 0 2 0 -15.8 0 -15.6 -16 04/04/2005 01:30:00 2.5 0.4 3.8 1.9 2.4 0.4 3.4 1.5 0.4 0 0.4 0.4 19 6 22 305 3 0 2 0 -15.6 0 -15.2 -15.8 04/04/2005 01:40:00 2.7 0.5 4.2 1.5 2.7 0.4 4.6 1.5 0.4 0 0.4 0.4 19 8 14 305 3 0 2 0 -15.6 0 -15.2 -15.8 04/04/2005 01:50:00 3.4 0.4 4.2 2.6 3.3 0.3 4.2 2.6 0.4 0 0.4 0.4 23 6 19 305 3 0 3 0 -15.4 0 -15.2 -15.6 04/04/2005 02:00:00 3.4 0.4 4.6 2.6 3.3 0.4 4.6 2.6 0.4 0 0.4 0.4 21 3 20 305 3 0 3 0 -15.3 0 -15 -15.4 04/04/2005 02:10:00 3.4 0.2 3.8 3 3.3 0.2 3.8 2.6 0.4 0 0.4 0.4 18 1 18 305 3 0 2 0 -15.3 0 -15 -15.6 04/04/2005 02:20:00 3.2 0.3 3.8 2.3 3.1 0.2 3.8 2.6 0.4 0 0.4 0.4 19 2 14 305 3 0 2 0 -15.1 0 -15 -15.2 04/04/2005 02:30:00 2.5 0.3 3.4 1.9 2.8 0.2 3.4 2.3 0.4 0 0.4 0.4 28 6 18 305 3 0 2 0 -15.2 0 -15 -15.4 04/04/2005 02:40:00 3.4 0.3 4.2 2.6 3.6 0.3 4.2 2.6 0.4 0 0.4 0.4 29 5 26 305 3 0 2 0 -15.3 0.1 -15 -15.6 04/04/2005 02:50:00 3.9 0.3 4.6 3 3.9 0.3 4.6 3 0.4 0 0.4 0.4 29 3 28 305 3 0 3 0 -15.8 0 -15.6 -16 04/04/2005 03:00:00 4 0.3 4.9 3 3.9 0.3 4.6 3 0.4 0 0.4 0.4 26 4 23 305 3 0 3 0 -15.7 0.1 -15.4 -16 04/04/2005 03:10:00 3.5 0.5 4.6 2.3 3.5 0.3 4.6 2.6 0.4 0 0.4 0.4 27 6 17 305 3 0 2 0 -15.7 0 -15.6 -15.8 04/04/2005 03:20:00 2.9 0.4 3.8 2.3 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 31 7 18 305 3 0 2 0 -16 0.1 -15.6 -16.4 04/04/2005 03:30:00 3.2 0.3 4.2 2.3 3.3 0.3 4.2 2.6 0.4 0 0.4 0.4 27 5 25 305 2 0 2 0 -15.9 0 -15.8 -16 04/04/2005 03:40:00 4 0.8 5.7 2.3 4.2 0.7 6.1 2.6 0.4 0 0.4 0.4 30 6 43 305 2 0 2 0 -15.8 0 -15.6 -16 04/04/2005 03:50:00 4.8 0.4 6.1 3.4 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 23 6 22 305 2 0 3 0 -15.9 0.1 -15.6 -16.4 04/04/2005 04:00:00 3.9 0.6 5.7 3 3.9 0.5 4.9 3 0.4 0 0.4 0.4 19 5 13 305 2 0 2 0 -16.5 0.1 -16.2 -16.9 04/04/2005 04:10:00 4.1 0.5 5.3 3 4.3 0.5 5.3 3 0.4 0 0.4 0.4 37 5 38 305 2 0 2 0 -16.3 0.2 -16 -16.6 04/04/2005 04:20:00 4.3 0.4 5.3 3 4.2 0.4 5.3 3.4 0.4 0 0.4 0.4 23 5 25 305 2 0 2 0 -16.3 0.2 -15.8 -16.9 04/04/2005 04:30:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3.4 0.4 0 0.4 0.4 27 7 37 305 2 0 2 0 -16.7 0.2 -16 -16.9 04/04/2005 04:40:00 4.2 0.5 5.3 2.6 4.2 0.4 5.3 3.4 0.4 0 0.4 0.4 23 8 29 305 2 0 2 0 -16.2 0.1 -16 -16.6 04/04/2005 04:50:00 5 0.3 5.7 3.8 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 12 2 12 305 2 0 2 0 -16.3 0.1 -16 -16.6 04/04/2005 05:00:00 3.5 1 4.9 1.5 3.1 0.7 4.2 1.5 0.4 0 0.4 0.4 22 17 10 305 2 0 2 0 -16.8 0.1 -16.4 -16.9 04/04/2005 05:10:00 3.5 0.5 5.3 1.9 3.6 0.5 5.3 2.6 0.4 0 0.4 0.4 48 6 39 305 2 0 2 0 -16 0.2 -15.6 -16.6 04/04/2005 05:20:00 4.5 0.5 5.7 3.4 4.6 0.5 5.7 3.4 0.4 0 0.4 0.4 38 6 39 305 3 0 2 0 -15.6 0.1 -15.2 -16 04/04/2005 05:30:00 4.2 0.7 5.7 2.6 4.2 0.6 5.7 2.6 0.4 0 0.4 0.4 35 5 27 305 2 0 2 0 -16 0.2 -15.8 -16.6 04/04/2005 05:40:00 3.6 0.5 5.3 2.3 3.7 0.5 5.3 2.6 0.4 0 0.4 0.4 46 10 57 305 2 0 2 0 -16.1 0.2 -15.6 -16.6 04/04/2005 05:50:00 4 0.4 4.9 3 4.2 0.4 5.3 3 0.4 0 0.4 0.4 30 8 33 305 3 0 2 0 -15.5 0 -15.2 -15.8 04/04/2005 06:00:00 4.2 0.3 4.9 3.4 4.4 0.3 5.3 3.8 0.4 0 0.4 0.4 18 4 17 305 2 0 2 0 -15.8 0.1 -15.4 -16 04/04/2005 06:10:00 3.2 0.9 4.9 1.1 3.4 0.9 4.9 1.5 0.4 0 0.4 0.4 16 3 13 305 2 0 2 0 -16.4 0.1 -16 -16.9 04/04/2005 06:20:00 0.6 0.4 1.9 0.4 1 0.5 1.9 0.4 0.4 0 0.4 0.4 42 11 21 305 2 0 2 0 -16.9 0 -16.6 -17.1 04/04/2005 06:30:00 2.1 1 3.8 0.4 2.4 0.8 3.8 0.7 0.4 0 0.4 0.4 22 10 11 305 2 0 2 0 -15.9 0.3 -15.6 -16.9 04/04/2005 06:40:00 2.9 0.4 3.8 1.9 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 20 9 13 305 2 0 2 0 -16 0.2 -15.6 -16.4 04/04/2005 06:50:00 2 0.3 3 1.5 2.3 0.2 3 1.5 0.4 0 0.4 0.4 54 9 40 305 2 0 2 0 -16.6 0.2 -16 -16.9 04/04/2005 07:00:00 3.3 0.3 4.2 2.3 3.6 0.4 4.2 1.9 0.4 0 0.4 0.4 24 5 25 305 2 0 2 0 -15.9 0.1 -15.6 -16.4 04/04/2005 07:10:00 2.1 0.5 3 1.5 2.5 0.5 3.4 1.5 0.4 0 0.4 0.4 49 17 25 305 3 0 2 0 -16.4 0.1 -16.2 -16.9 04/04/2005 07:20:00 2.7 0.7 4.6 1.5 2.9 0.6 4.6 1.9 0.4 0 0.4 0.4 50 16 29 305 3 0 2 0 -16.3 0.5 -15.4 -16.9 04/04/2005 07:30:00 3.9 0.4 4.9 3 4.1 0.4 5.3 3 0.4 0 0.4 0.4 23 4 32 305 3 0 3 0 -15.8 0.3 -15.2 -16.4 04/04/2005 07:40:00 2.6 0.3 3 1.9 2.9 0.3 3.4 2.3 0.4 0 0.4 0.4 53 10 31 305 3 0 2 0 -16.4 0 -16 -16.6 04/04/2005 07:50:00 2.9 0.6 3.8 1.9 3.2 0.5 4.2 2.3 0.4 0 0.4 0.4 33 9 26 305 3 0 2 0 -15.8 0 -15.6 -16 04/04/2005 08:00:00 2.3 0.5 3.4 1.1 2.6 0.6 3.8 1.5 0.4 0 0.4 0.4 45 11 31 305 3 0 3 0 -16.1 0.2 -15.8 -16.6 04/04/2005 08:10:00 2 0.5 3.4 1.1 2.3 0.5 3.4 1.5 0.4 0 0.4 0.4 44 13 22 305 3 0 2 0 -16.4 0 -16 -16.6 04/04/2005 08:20:00 2.5 0.4 3.8 1.5 2.8 0.4 3.8 1.9 0.4 0 0.4 0.4 33 6 28 305 3 0 2 0 -15.7 0.1 -15.6 -16 04/04/2005 08:30:00 1.8 0.4 2.6 1.1 2.1 0.3 3 1.5 0.4 0 0.4 0.4 45 5 25 305 3 0 3 0 -15.8 0 -15.6 -15.8 04/04/2005 08:40:00 2 0.4 3 1.1 2.4 0.4 3.4 1.5 0.4 0 0.4 0.4 34 11 38 305 3 0 3 0 -15.5 0.1 -15 -15.8 04/04/2005 08:50:00 2.5 0.4 3.4 1.5 2.6 0.4 3.8 1.9 0.4 0 0.4 0.4 48 9 50 305 3 0 3 0 -15.7 0.2 -15 -16.2 04/04/2005 09:00:00 2.6 0.4 3.4 1.5 2.8 0.3 3.8 1.9 0.4 0 0.4 0.4 39 7 43 305 4 0 4 0 -15.4 0.2 -14.8 -15.8 04/04/2005 09:10:00 2.5 0.4 3.8 1.5 2.6 0.3 3.4 1.9 0.4 0 0.4 0.4 41 8 51 305 3 0 4 0 -15.2 0.1 -14.8 -15.4 04/04/2005 09:20:00 2.7 0.3 3.4 1.5 2.8 0.3 3.4 1.9 0.4 0 0.4 0.4 46 5 42 305 3 0 3 0 -15 0.1 -14.4 -15.2 04/04/2005 09:30:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 0.7 0.4 0 0.4 0.4 49 9 53 305 3 0 3 0 -14.7 0.2 -14.3 -15 04/04/2005 09:40:00 1.7 0.5 3 0.7 1.7 0.4 2.6 1.1 0.4 0 0.4 0.4 46 7 41 305 3 0 3 0 -14.4 0.2 -13.7 -14.6 04/04/2005 09:50:00 1.3 0.7 3 0.4 1.2 0.5 2.3 0.4 0.4 0 0.4 0.4 35 13 48 305 3 0 3 0 -13.9 0.2 -13.3 -14.3 04/04/2005 10:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 29 12 44 305 3 0 3 0 -13.9 0.3 -13.5 -14.6 04/04/2005 10:10:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 358 43 337 305 2 0 2 0 -14.4 0.1 -13.9 -14.6 04/04/2005 10:20:00 0.4 0.1 1.1 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 238 38 203 305 0 0 0 0 -14.4 0.1 -14.1 -14.6 04/04/2005 10:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 91 90 305 305 1 0 0 0 -13.7 0.2 -13.1 -14.3 04/04/2005 10:40:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 43 19 29 305 1 0 1 0 -13.7 0.3 -13.1 -14.3 04/04/2005 10:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 50 28 26 305 1 0 1 0 -13.5 0.1 -13.1 -13.9 04/04/2005 11:00:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 18 27 40 305 1 0 1 0 -13.4 0.2 -12.9 -13.7 04/04/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 0 305 305 1 0 0 0 -13 0.1 -12.5 -13.1 04/04/2005 11:20:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 6 17 305 305 1 0 1 0 -12.2 0.5 -11.3 -13.1 04/04/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 9 0 305 305 0 0 0 0 -12.6 0.6 -10.9 -13.3 04/04/2005 11:40:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 9 0 9 305 1 0 0 0 -12.6 0.2 -11.7 -12.9 04/04/2005 11:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 9 1 305 305 0 0 0 0 -13 0 -12.5 -13.3 04/04/2005 12:00:00 0.5 0.3 1.5 0.4 1.1 0.4 1.9 0.4 0.4 0 0.4 0.4 235 43 210 305 0 0 0 0 -13.4 0.1 -12.7 -13.7 04/04/2005 12:10:00 0.4 0.1 1.1 0.4 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 204 18 169 305 0 0 0 0 -12.4 0.3 -12.1 -13.1 04/04/2005 12:20:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 95 82 8 305 0 0 0 0 -11.4 0.3 -10.7 -12.1 04/04/2005 12:30:00 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 16 5 20 305 0 0 0 0 -10.2 0.4 -9.4 -11.1 04/04/2005 12:40:00 1.1 0.3 1.5 0.4 1.1 0.2 1.5 0.7 0.4 0 0.4 0.4 43 17 19 305 0 0 0 0 -11 0.4 -9.8 -11.5 04/04/2005 12:50:00 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 62 22 65 305 0 0 0 0 -9 0.4 -8.2 -10 04/04/2005 13:00:00 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.4 0.4 0 0.4 0.4 50 15 48 305 0 0 0 0 -8.4 0.6 -7.3 -9.2 04/04/2005 13:10:00 1.3 0.4 2.3 0.4 1.5 0.4 2.6 0.7 0.4 0 0.4 0.4 31 7 25 305 0 0 0 0 -9.2 1.5 -6.9 -11.3 04/04/2005 13:20:00 1 0.5 1.9 0.4 1.3 0.4 2.3 0.7 0.4 0 0.4 0.4 60 12 60 305 0 0 0 0 -10 0.4 -9.2 -11.3 04/04/2005 13:30:00 0.7 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0 0.4 0.4 29 5 41 305 0 0 0 0 -10.2 0.7 -8.6 -10.9 04/04/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 27 0 305 305 0 0 0 0 -8.4 0.4 -7.3 -9 04/04/2005 13:50:00 0.5 0.2 1.1 0.4 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 121 66 189 305 0 0 0 0 -8 0.6 -6.9 -9 04/04/2005 14:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 178 6 305 305 0 0 0 0 -8.4 0.5 -7.5 -9.2 04/04/2005 14:10:00 0.6 0.5 2.3 0.4 0.7 0.6 2.6 0.4 0.4 0 0.4 0.4 114 53 148 305 0 0 0 0 -8.2 0.8 -6.4 -9.2 04/04/2005 14:20:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 46 0 305 305 0 0 0 0 -7.4 1.4 -5.6 -10 04/04/2005 14:30:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 46 0 305 305 0 0 0 0 -9.2 0.3 -8.4 -9.8 04/04/2005 14:40:00 1 0.5 2.3 0.4 1.5 0.4 2.3 0.4 0.4 0 0.4 0.4 205 38 218 305 0 0 0 0 -10.5 0.3 -9.2 -11.1 04/04/2005 14:50:00 1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.4 0 0.4 0.4 172 36 194 305 0 0 0 0 -10.7 0.3 -9.8 -11.3 04/04/2005 15:00:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 107 22 151 305 0 0 0 0 -8 0.8 -6.9 -10 04/04/2005 15:10:00 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 65 20 53 305 0 0 0 0 -5.9 0.5 -5.1 -6.9 04/04/2005 15:20:00 0.6 0.3 1.5 0.4 1 0.3 1.5 0.4 0.4 0 0.4 0.4 52 0 52 305 0 0 0 0 -9 0.8 -6.9 -9.8 04/04/2005 15:30:00 0.4 0.1 0.7 0.4 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 52 0 52 305 0 0 0 0 -8.4 0.9 -6.9 -9.6 04/04/2005 15:40:00 0.9 0.5 2.3 0.4 1.2 0.4 2.3 0.4 0.4 0 0.4 0.4 57 5 50 305 0 0 0 0 -8.6 0.4 -7.7 -9.4 04/04/2005 15:50:00 1.9 0.4 2.6 0.7 2 0.3 2.6 1.1 0.4 0 0.4 0.4 55 11 40 305 0 0 0 0 -10.2 0.4 -8.8 -10.7 04/04/2005 16:00:00 2.5 0.3 3.4 1.9 2.6 0.3 3 1.9 0.4 0 0.4 0.4 49 7 56 305 0 0 0 0 -11 0.1 -10.4 -11.3 04/04/2005 16:10:00 1.8 0.3 2.6 1.1 2 0.3 2.6 1.1 0.4 0 0.4 0.4 45 8 47 305 0 0 0 0 -10.8 0.2 -10 -11.3 04/04/2005 16:20:00 1.6 0.8 2.6 0.4 1.8 0.7 3 0.4 0.4 0 0.4 0.4 54 18 43 305 0 0 0 0 -10.6 0.5 -9.2 -11.3 04/04/2005 16:30:00 1.8 0.4 2.6 0.7 1.9 0.4 3 0.7 0.4 0 0.4 0.4 69 17 80 305 0 0 0 0 -8.5 0.4 -7.7 -9.2 04/04/2005 16:40:00 2.1 0.3 2.6 1.5 2.2 0.2 2.6 1.5 0.4 0 0.4 0.4 41 5 38 305 0 0 0 0 -10.4 0.4 -9.2 -11.1 04/04/2005 16:50:00 2.4 0.4 3 1.5 2.4 0.4 3 1.5 0.4 0 0.4 0.4 63 11 53 305 0 0 0 0 -10.9 0.1 -10.4 -11.1 04/04/2005 17:00:00 2.7 0.3 3.8 2.3 2.8 0.3 3.8 2.3 0.4 0 0.4 0.4 56 6 52 305 0 0 0 0 -10.9 0.1 -10.4 -11.3 04/04/2005 17:10:00 2.6 0.4 3.8 1.5 2.8 0.4 3.8 1.9 0.4 0 0.4 0.4 53 11 67 305 0 0 0 0 -11.1 0.1 -10.7 -11.3 04/04/2005 17:20:00 2.7 0.5 3.8 1.5 2.7 0.4 3.4 1.5 0.4 0 0.4 0.4 70 10 67 305 0 0 0 0 -9.8 0.6 -8.8 -11.1 04/04/2005 17:30:00 2.2 0.5 3.8 1.1 2.2 0.4 3.8 1.5 0.4 0 0.4 0.4 81 19 85 305 0 0 0 0 -9 0.4 -8.2 -9.8 04/04/2005 17:40:00 2.2 0.3 3 1.1 2.3 0.3 3 1.5 0.4 0 0.4 0.4 50 7 49 305 0 0 0 0 -10.4 0.5 -9 -11.1 04/04/2005 17:50:00 2.5 0.4 3.8 1.5 2.6 0.3 3.4 1.9 0.4 0 0.4 0.4 59 15 79 305 0 0 0 0 -11 0.3 -10 -11.3 04/04/2005 18:00:00 2.1 0.5 3.4 1.1 2.2 0.5 3.4 1.1 0.4 0 0.4 0.4 74 10 85 305 0 0 0 0 -9.4 0.3 -8.6 -10 04/04/2005 18:10:00 2 0.5 3.4 1.1 2.1 0.5 3.4 1.1 0.4 0 0.4 0.4 63 8 69 305 0 0 0 0 -10 0.4 -8.8 -10.4 04/04/2005 18:20:00 2.4 0.3 3 1.5 2.4 0.3 3 1.9 0.4 0 0.4 0.4 67 7 80 305 0 0 0 0 -10.3 0.2 -9.6 -10.7 04/04/2005 18:30:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 0.4 0 0.4 0.4 57 5 52 305 0 0 0 0 -10.4 0.2 -9.6 -10.9 04/04/2005 18:40:00 2.5 0.3 3 1.5 2.3 0.3 3.4 1.5 0.4 0 0.4 0.4 59 5 57 305 0 0 0 0 -11 0.1 -10.4 -11.3 04/04/2005 18:50:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 2.3 0.4 0 0.4 0.4 58 6 59 305 0 0 0 0 -11.2 0.2 -10.9 -11.5 04/04/2005 19:00:00 3.4 0.4 4.2 2.6 3.3 0.3 4.2 2.6 0.4 0 0.4 0.4 75 8 86 305 0 0 0 0 -10.9 0.4 -9.6 -11.3 04/04/2005 19:10:00 3.7 0.3 4.6 2.6 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 80 5 90 305 0 0 0 0 -9.8 0.1 -9.2 -10.2 04/04/2005 19:20:00 3.2 0.5 4.6 2.3 3.1 0.5 4.2 1.9 0.4 0 0.4 0.4 73 7 78 305 0 0 0 0 -11.1 0.4 -10 -11.5 04/04/2005 19:30:00 3.5 0.3 4.6 2.6 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 63 6 71 305 0 0 0 0 -11.5 0.1 -10.9 -11.9 04/04/2005 19:40:00 3.3 0.4 4.2 2.6 3.3 0.4 4.2 2.3 0.4 0 0.4 0.4 59 5 62 305 0 0 0 0 -11.5 0 -11.3 -11.7 04/04/2005 19:50:00 3.6 0.4 4.6 2.6 3.5 0.3 4.6 2.6 0.4 0 0.4 0.4 66 7 73 305 0 0 0 0 -11.9 0.2 -11.3 -12.1 04/04/2005 20:00:00 3.4 0.4 4.2 2.3 3.3 0.4 4.2 2.6 0.4 0 0.4 0.4 62 7 55 305 0 0 0 0 -12 0 -11.7 -12.1 04/04/2005 20:10:00 3 0.3 3.8 2.3 2.9 0.3 3.8 2.3 0.4 0 0.4 0.4 58 5 67 305 0 0 0 0 -12 0 -11.9 -12.3 04/04/2005 20:20:00 3 0.4 3.8 2.3 2.9 0.5 3.8 1.9 0.4 0 0.4 0.4 56 5 55 305 0 0 0 0 -12.1 0 -12.1 -12.5 04/04/2005 20:30:00 2.5 0.3 3 1.9 2.4 0.3 3 1.9 0.4 0 0.4 0.4 62 4 60 305 0 0 0 0 -12.2 0 -12.1 -12.5 04/04/2005 20:40:00 2.3 0.5 3.4 1.1 2.1 0.4 3 1.1 0.4 0 0.4 0.4 63 4 63 305 0 0 0 0 -12 0 -11.9 -12.1 04/04/2005 20:50:00 2.3 0.4 3 1.5 1.9 0.4 2.6 0.4 0.4 0 0.4 0.4 67 5 69 305 0 0 0 0 -12 0 -12.1 -12.3 04/04/2005 21:00:00 1.4 0.7 3 0.4 1.1 0.6 2.6 0.4 0.4 0 0.4 0.4 68 16 61 305 0 0 0 0 -12.5 0.1 -11.9 -12.7 04/04/2005 21:10:00 0.7 0.4 1.9 0.4 0.9 0.4 2.3 0.4 0.4 0 0.4 0.4 70 20 53 305 0 0 0 0 -13 0.1 -12.7 -13.3 04/04/2005 21:20:00 0.8 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0 0.4 0.4 88 9 70 305 0 0 0 0 -13.6 0 -13.3 -13.7 04/04/2005 21:30:00 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 92 21 101 305 0 0 0 0 -13.9 0.1 -13.3 -14.3 04/04/2005 21:40:00 1.3 0.8 2.6 0.4 1.6 0.6 3 0.4 0.4 0 0.4 0.4 100 10 100 305 0 0 0 0 -14.2 0 -13.7 -14.3 04/04/2005 21:50:00 1.2 0.5 2.6 0.4 1.4 0.4 2.6 0.7 0.4 0 0.4 0.4 103 12 96 305 0 0 0 0 -14.1 0 -13.7 -14.3 04/04/2005 22:00:00 1.4 0.7 3.4 0.4 1.7 0.6 3 0.4 0.4 0 0.4 0.4 101 23 101 305 0 0 0 0 -14.4 0 -13.9 -14.6 04/04/2005 22:10:00 2 0.5 3 0.7 2.2 0.4 3 1.1 0.4 0 0.4 0.4 96 11 93 305 0 0 0 0 -14.2 0 -13.7 -14.4 04/04/2005 22:20:00 1.3 0.7 2.6 0.4 1.2 0.5 2.3 0.4 0.4 0 0.4 0.4 103 21 102 305 0 0 0 0 -14.2 0 -13.7 -14.4 04/04/2005 22:30:00 2 0.5 3.4 0.7 1.9 0.5 3 0.7 0.4 0 0.4 0.4 84 11 97 305 0 0 0 0 -14.3 0 -13.7 -14.4 04/04/2005 22:40:00 2.2 0.8 3.8 0.4 2.3 0.6 3.8 0.4 0.4 0 0.4 0.4 94 15 89 305 0 0 0 0 -14.1 0.1 -13.7 -14.3 04/04/2005 22:50:00 1 0.8 3 0.4 1.2 0.7 2.6 0.4 0.4 0 0.4 0.4 111 64 71 305 0 0 0 0 -13.7 0 -13.3 -14.1 04/04/2005 23:00:00 0.7 0.5 2.6 0.4 0.9 0.6 2.3 0.4 0.4 0 0.4 0.4 144 58 199 305 0 0 0 0 -13.8 0.1 -13.1 -14.1 04/04/2005 23:10:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 264 82 129 305 0 0 0 0 -14.1 0.4 -13.1 -14.6 04/04/2005 23:20:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 194 26 232 305 0 0 0 0 -14.8 0.1 -14.3 -15 04/04/2005 23:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 173 58 305 305 0 0 0 0 -14.9 0.1 -14.3 -15 04/04/2005 23:40:00 0.5 0.4 1.9 0.4 0.6 0.5 1.9 0.4 0.4 0 0.4 0.4 20 26 49 305 0 0 0 0 -14.9 0.1 -14.4 -15.2 04/04/2005 23:50:00 0.5 0.2 1.5 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 69 32 104 305 0 0 0 0 -15 0.2 -14.3 -15.4 04/05/2005 00:00:00 1.3 1 4.2 0.4 1.3 0.8 4.2 0.4 0.4 0 0.4 0.4 87 39 108 305 0 0 0 0 -14.8 0.3 -14.1 -15.2 04/05/2005 00:10:00 1.6 1 4.6 0.4 1.6 0.9 4.6 0.4 0.4 0 0.4 0.4 99 41 89 305 0 0 0 0 -14.8 0.1 -14.3 -15 04/05/2005 00:20:00 2.6 1.3 4.6 0.4 2.4 1.1 4.2 0.4 0.4 0 0.4 0.4 116 17 118 305 0 0 0 0 -15.2 0.3 -14.3 -15.6 04/05/2005 00:30:00 2.8 0.8 4.6 0.4 2.5 0.5 3.8 1.5 0.4 0 0.4 0.4 97 23 101 305 1 0 0 0 -14.9 0 -14.6 -15.2 04/05/2005 00:40:00 1.6 1 4.2 0.4 1.5 0.8 3.4 0.4 0.4 0 0.4 0.4 89 30 106 305 1 0 1 0 -14.6 0.1 -14.3 -14.8 04/05/2005 00:50:00 2.7 0.7 4.2 1.1 2.2 0.6 3.8 0.4 0.4 0 0.4 0.4 90 11 105 305 1 0 1 0 -14.4 0.2 -14.1 -14.6 04/05/2005 01:00:00 2.1 1.2 4.2 0.4 1.6 1.1 4.2 0.4 0.4 0 0.4 0.4 115 22 90 305 1 0 1 0 -14.5 0.1 -14.1 -14.6 04/05/2005 01:10:00 0.8 0.6 3.4 0.4 0.8 0.6 2.6 0.4 0.4 0 0.4 0.4 111 94 127 305 1 0 1 0 -14.7 0 -14.3 -14.8 04/05/2005 01:20:00 1.4 0.6 3.4 0.4 1.9 0.6 4.2 0.4 0.4 0 0.4 0.4 10 29 39 305 1 0 1 0 -13.8 0.2 -13.5 -14.3 04/05/2005 01:30:00 1.1 0.6 3.4 0.4 1.7 0.7 4.2 0.4 0.4 0 0.4 0.4 345 36 354 305 1 0 1 0 -13.6 0 -13.3 -13.7 04/05/2005 01:40:00 1 0.6 2.6 0.4 1.5 0.6 3 0.4 0.4 0 0.4 0.4 13 23 30 305 1 0 1 0 -13.5 0.1 -13.3 -13.7 04/05/2005 01:50:00 1.4 0.8 3.4 0.4 1.7 0.7 3.4 0.4 0.4 0 0.4 0.4 6 39 17 305 1 0 1 0 -13.1 0 -12.9 -13.3 04/05/2005 02:00:00 1.4 0.9 3.4 0.4 1.4 0.7 3 0.4 0.4 0 0.4 0.4 51 35 75 305 1 0 1 0 -13.2 0.1 -12.5 -13.5 04/05/2005 02:10:00 1.1 0.6 3 0.4 1.3 0.6 3 0.4 0.4 0 0.4 0.4 56 36 56 305 1 0 1 0 -13.6 0 -12.9 -13.7 04/05/2005 02:20:00 1 0.7 3 0.4 1.3 0.7 3.4 0.4 0.4 0 0.4 0.4 17 49 12 305 1 0 1 0 -13.7 0.1 -13.1 -14.3 04/05/2005 02:30:00 1 0.5 2.3 0.4 1.8 0.5 3 0.7 0.4 0 0.4 0.4 354 24 1 305 1 0 1 0 -13.7 0.2 -13.3 -14.3 04/05/2005 02:40:00 0.6 0.4 1.9 0.4 0.8 0.6 3 0.4 0.4 0 0.4 0.4 307 69 14 305 1 0 1 0 -13.9 0.3 -13.3 -14.6 04/05/2005 02:50:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 275 22 268 305 0 0 0 0 -14.7 0 -14.4 -14.8 04/05/2005 03:00:00 0.5 0.4 2.3 0.4 0.8 0.5 2.6 0.4 0.4 0 0.4 0.4 257 45 297 305 0 0 0 0 -14.8 0 -14.3 -15 04/05/2005 03:10:00 0.6 0.5 2.3 0.4 0.9 0.6 2.6 0.4 0.4 0 0.4 0.4 235 22 281 305 0 0 0 0 -15.1 0.2 -14.6 -15.8 04/05/2005 03:20:00 0.5 0.3 1.5 0.4 0.9 0.4 1.5 0.4 0.4 0 0.4 0.4 215 23 257 305 0 0 0 0 -15.3 0.3 -14.8 -15.8 04/05/2005 03:30:00 0.4 0.2 1.5 0.4 0.8 0.5 2.3 0.4 0.4 0 0.4 0.4 183 7 191 305 1 0 1 0 -15.2 0.2 -14.6 -15.8 04/05/2005 03:40:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 103 51 59 305 1 0 1 0 -16.2 0.2 -15.8 -16.6 04/05/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 45 0 305 305 1 0 1 0 -16.6 0.1 -16 -16.9 04/05/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 0 305 305 1 0 0 0 -16.9 0 -16.4 -17.1 04/05/2005 04:10:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 59 12 82 305 1 0 1 0 -17.4 0.3 -16.6 -18.1 04/05/2005 04:20:00 0.5 0.2 1.1 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 90 10 93 305 1 0 1 0 -17.7 0.2 -17.3 -18.1 04/05/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 99 0 305 305 1 0 0 0 -17.8 0.1 -17.5 -18.1 04/05/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 99 0 305 305 1 0 0 0 -17.7 0.2 -16.9 -18.1 04/05/2005 04:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 88 12 305 305 1 0 1 0 -17.2 0.2 -16.6 -17.7 04/05/2005 05:00:00 0.4 0.2 1.1 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 88 12 100 305 1 0 1 0 -18 0.2 -17.1 -18.4 04/05/2005 05:10:00 1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.4 0 0.4 0.4 75 10 84 305 1 0 1 0 -17.7 0.1 -17.1 -18.1 04/05/2005 05:20:00 1.6 0.3 2.3 1.1 1.7 0.3 2.3 0.7 0.4 0 0.4 0.4 74 7 80 305 1 0 1 0 -17.9 0.3 -16.9 -18.4 04/05/2005 05:30:00 1.5 0.6 3.4 0.4 1.7 0.4 3.4 0.7 0.4 0 0.4 0.4 71 13 87 305 1 0 1 0 -18 0.4 -17.1 -18.8 04/05/2005 05:40:00 0.7 0.4 1.5 0.4 1.2 0.3 1.9 0.4 0.4 0 0.4 0.4 59 10 64 305 1 0 1 0 -18.1 0.3 -17.3 -18.6 04/05/2005 05:50:00 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0 0.4 0.4 85 22 71 305 1 0 1 0 -18.1 0.5 -16.9 -18.8 04/05/2005 06:00:00 1.9 0.5 3.4 0.7 2.2 0.5 3.4 1.1 0.4 0 0.4 0.4 69 15 83 305 1 0 1 0 -17 0.2 -16.6 -17.5 04/05/2005 06:10:00 1.8 0.5 3.4 0.7 2.2 0.4 3.4 1.1 0.4 0 0.4 0.4 74 17 99 305 2 0 2 0 -16.2 0.4 -15 -16.9 04/05/2005 06:20:00 2 0.7 3.4 0.4 2.5 0.6 3.8 1.1 0.4 0 0.4 0.4 52 15 50 305 2 0 2 0 -16.1 0.3 -15.2 -16.9 04/05/2005 06:30:00 2 1.2 4.2 0.4 2.5 1.1 4.6 0.4 0.4 0 0.4 0.4 67 33 54 305 2 0 2 0 -15.8 0.4 -15 -16.6 04/05/2005 06:40:00 0.7 0.5 2.6 0.4 1.4 0.5 3 0.7 0.4 0 0.4 0.4 71 27 70 305 2 0 2 0 -16.4 0.4 -15.6 -16.9 04/05/2005 06:50:00 1 0.7 3 0.4 1.7 0.6 3 0.4 0.4 0 0.4 0.4 63 35 96 305 2 0 2 0 -16 0.2 -15.6 -16.4 04/05/2005 07:00:00 3.1 0.7 4.9 1.1 3.1 0.6 4.2 1.1 0.4 0 0.4 0.4 84 15 106 305 2 0 2 0 -16.1 0.1 -15.8 -16.4 04/05/2005 07:10:00 2.7 1.1 4.9 0.4 2.9 1 4.9 0.7 0.4 0 0.4 0.4 83 17 89 305 2 0 2 0 -15.9 0 -15.6 -16.2 04/05/2005 07:20:00 2.8 1 5.3 0.4 3.1 0.8 4.9 0.7 0.4 0 0.4 0.4 59 35 100 305 2 0 2 0 -15.8 0 -15.6 -16 04/05/2005 07:30:00 1.5 1 4.2 0.4 2 1.1 4.6 0.4 0.4 0 0.4 0.4 24 69 29 305 2 0 2 0 -15.9 0.2 -15.6 -16.4 04/05/2005 07:40:00 0.8 0.6 3 0.4 1 0.6 3.4 0.4 0.4 0 0.4 0.4 330 72 90 305 2 0 2 0 -16.3 0 -16 -16.4 04/05/2005 07:50:00 1.9 1.5 6.1 0.4 1.8 1.3 6.1 0.4 0.4 0 0.4 0.4 306 112 111 305 2 0 2 0 -16.9 0.3 -16.4 -17.5 04/05/2005 08:00:00 5.6 0.5 6.8 4.2 5.4 0.7 6.8 3 0.4 0 0.4 0.4 119 6 133 305 2 0 2 0 -17.5 0 -17.3 -17.7 04/05/2005 08:10:00 5.5 0.6 6.8 3.4 5.2 1 6.8 1.9 0.4 0 0.4 0.4 119 6 121 305 2 0 2 0 -17.4 0 -17.1 -17.5 04/05/2005 08:20:00 6.5 0.5 7.6 4.9 6.6 0.7 8.4 3.8 0.4 0 0.4 0.4 115 3 113 305 2 0 2 0 -17.1 0.1 -16.9 -17.5 04/05/2005 08:30:00 7.1 0.6 8.4 5.3 7.2 0.7 8.4 5.3 0.4 0 0.4 0.4 119 4 117 305 2 0 2 0 -17 0 -16.9 -17.1 04/05/2005 08:40:00 7.3 0.5 8.4 5.3 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 123 3 118 305 2 0 2 0 -16.9 0 -16.6 -17.1 04/05/2005 08:50:00 6.6 1 8.8 2.6 6.9 0.9 9.1 4.6 0.4 0 0.4 0.4 124 12 107 305 2 0 2 0 -16.6 0.2 -16.4 -16.9 04/05/2005 09:00:00 6 1.2 9.1 3 6.4 1.1 8.8 3.4 0.4 0 0.4 0.4 124 12 142 305 2 0 1 0 -16.4 0.1 -16 -16.6 04/05/2005 09:10:00 4.9 1.7 8 1.5 5.4 1.6 8.4 1.9 0.4 0 0.4 0.4 127 15 120 305 1 0 1 0 -15.8 0.3 -15.2 -16.4 04/05/2005 09:20:00 6.1 1.3 8.4 2.3 6.5 1.2 8.8 3 0.4 0 0.4 0.4 121 11 118 305 1 0 1 0 -15.8 0 -15.4 -16 04/05/2005 09:30:00 7.3 0.5 8.8 4.6 7.5 0.4 9.1 6.5 0.4 0 0.4 0.4 120 3 119 305 1 0 1 0 -16.2 0 -16 -16.4 04/05/2005 09:40:00 6.7 0.5 8 4.9 6.9 0.5 8.4 5.3 0.4 0 0.4 0.4 125 5 120 305 1 0 1 0 -16 0 -15.8 -16.2 04/05/2005 09:50:00 5.6 1 6.8 1.9 6 0.8 8 2.3 0.4 0 0.4 0.4 123 12 125 305 1 0 1 0 -15.8 0 -15.6 -16 04/05/2005 10:00:00 5.1 0.8 6.8 3 5.6 0.6 6.8 3.4 0.4 0 0.4 0.4 118 12 123 305 1 0 1 0 -15.7 0 -15.6 -15.8 04/05/2005 10:10:00 4.9 1 7.2 1.9 5.2 0.9 7.2 2.3 0.4 0 0.4 0.4 116 15 95 305 1 0 1 0 -15.3 0.1 -15 -15.6 04/05/2005 10:20:00 4.7 1.1 6.8 0.7 5.3 0.9 6.8 2.6 0.4 0 0.4 0.4 122 16 120 305 0 0 0 0 -15.2 0 -15 -15.4 04/05/2005 10:30:00 6.2 0.5 7.2 3.8 6.4 0.4 7.2 4.9 0.4 0 0.4 0.4 128 5 131 305 0 0 0 0 -15.4 0 -15 -15.6 04/05/2005 10:40:00 6.1 0.6 7.2 3.8 6.6 0.4 7.2 4.6 0.4 0 0.4 0.4 121 4 123 305 0 0 0 0 -15.5 0 -15.2 -15.6 04/05/2005 10:50:00 6 0.5 7.2 3.8 6.6 0.3 7.2 5.3 0.4 0 0.4 0.4 122 4 124 305 0 0 0 0 -15.4 0 -15.2 -15.6 04/05/2005 11:00:00 5.7 0.6 7.2 3.4 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 123 5 123 305 0 0 0 0 -15.2 0 -15 -15.4 04/05/2005 11:10:00 5.9 0.5 7.2 4.2 6.3 0.5 7.6 3.8 0.4 0 0.4 0.4 118 8 87 305 0 0 0 0 -15.1 0 -14.8 -15.2 04/05/2005 11:20:00 5.5 0.8 7.2 2.3 5.9 0.5 7.2 3.8 0.4 0 0.4 0.4 111 8 111 305 0 0 0 0 -14.9 0.1 -14.6 -15 04/05/2005 11:30:00 5.5 1 7.6 2.6 6 0.8 7.6 3.8 0.4 0 0.4 0.4 109 11 111 305 0 0 0 0 -14.8 0 -14.6 -15 04/05/2005 11:40:00 5.6 0.7 7.2 3.8 6.1 0.7 7.6 3.8 0.4 0 0.4 0.4 107 10 105 305 0 0 0 0 -14.7 0 -14.6 -14.8 04/05/2005 11:50:00 5.5 0.9 7.6 1.9 6.1 0.7 7.6 3.4 0.4 0 0.4 0.4 111 10 102 305 0 0 0 0 -14.6 0.1 -14.3 -14.6 04/05/2005 12:00:00 6 0.9 8.4 3.4 6.5 0.7 8 4.2 0.4 0 0.4 0.4 110 9 103 305 0 0 0 0 -14.4 0 -14.3 -14.4 04/05/2005 12:10:00 6.1 0.9 7.6 2.3 6.5 0.6 8 4.2 0.4 0 0.4 0.4 108 9 108 305 0 0 0 0 -14.4 0 -14.3 -14.4 04/05/2005 12:20:00 6.3 1 8.8 3.8 6.8 0.8 8.8 3.8 0.4 0 0.4 0.4 112 8 93 305 0 0 0 0 -14.4 0 -14.3 -14.6 04/05/2005 12:30:00 6.1 0.9 8 3.4 6.6 0.8 8 4.2 0.4 0 0.4 0.4 110 8 113 305 0 0 0 0 -14.3 0 -14.3 -14.4 04/05/2005 12:40:00 6.1 0.6 7.2 3.8 6.4 0.6 8 4.6 0.4 0 0.4 0.4 114 7 119 305 0 0 0 0 -14.1 0.1 -13.9 -14.3 04/05/2005 12:50:00 5.5 0.5 6.8 3.8 5.4 0.6 6.5 3.8 0.4 0 0.4 0.4 113 5 108 305 0 0 0 0 -13.7 0.2 -13.3 -14.1 04/05/2005 13:00:00 5.8 0.6 7.2 3.8 5.8 0.6 7.2 4.2 0.4 0 0.4 0.4 110 5 111 305 0 0 0 0 -13.5 0 -13.3 -13.7 04/05/2005 13:10:00 5.3 0.5 6.5 3.4 5.4 0.5 6.8 3.4 0.4 0 0.4 0.4 119 6 112 305 0 0 0 0 -13.2 0.1 -12.9 -13.5 04/05/2005 13:20:00 5.6 0.6 6.8 4.2 5.6 0.6 7.2 3.8 0.4 0 0.4 0.4 118 7 121 305 0 0 0 0 -13 0 -12.9 -13.3 04/05/2005 13:30:00 5.9 0.5 7.6 4.6 6 0.5 7.2 4.2 0.4 0 0.4 0.4 118 6 116 305 0 0 0 0 -13 0 -12.9 -13.3 04/05/2005 13:40:00 6.1 0.5 6.8 4.9 6.1 0.5 6.8 4.9 0.4 0 0.4 0.4 121 4 123 305 0 0 0 0 -13 0 -12.9 -13.3 04/05/2005 13:50:00 6 0.4 6.8 4.9 6 0.4 7.2 4.9 0.4 0 0.4 0.4 121 4 122 305 0 0 0 0 -12.9 0 -12.7 -13.1 04/05/2005 14:00:00 5.2 0.5 6.1 3.8 5.2 0.5 6.5 4.2 0.4 0 0.4 0.4 111 7 118 305 0 0 0 0 -12.6 0 -12.3 -12.9 04/05/2005 14:10:00 4.9 0.4 5.7 3.8 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 104 7 116 305 0 0 0 0 -12.2 0.1 -12.1 -12.5 04/05/2005 14:20:00 4.9 0.5 6.1 3.8 4.8 0.5 6.1 3.4 0.4 0 0.4 0.4 97 5 104 305 0 0 0 0 -12 0 -11.9 -12.3 04/05/2005 14:30:00 4.8 0.5 6.1 3.4 4.7 0.5 5.7 3 0.4 0 0.4 0.4 95 6 91 305 0 0 0 0 -11.9 0.1 -11.7 -12.1 04/05/2005 14:40:00 4.1 0.6 5.3 2.6 4 0.6 5.3 2.6 0.4 0 0.4 0.4 93 8 99 305 0 0 0 0 -11.6 0.1 -11.1 -11.9 04/05/2005 14:50:00 3.6 0.5 4.9 1.9 3.5 0.5 4.6 2.3 0.4 0 0.4 0.4 79 11 98 305 0 0 0 0 -11.5 0.4 -10.9 -12.5 04/05/2005 15:00:00 3.6 0.6 4.9 1.9 3.6 0.5 4.9 2.3 0.4 0 0.4 0.4 67 9 75 305 0 0 0 0 -13 0.2 -12.5 -13.7 04/05/2005 15:10:00 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.6 0.4 0 0.4 0.4 70 8 76 305 0 0 0 0 -12.7 0.1 -12.5 -13.3 04/05/2005 15:20:00 3.9 0.5 4.9 2.6 3.8 0.4 4.6 2.6 0.4 0 0.4 0.4 67 6 69 305 0 0 0 0 -12.8 0.2 -12.3 -13.3 04/05/2005 15:30:00 3.7 0.4 4.9 2.6 3.6 0.4 4.6 2.6 0.4 0 0.4 0.4 65 5 68 305 0 0 0 0 -13 0.1 -12.7 -13.3 04/05/2005 15:40:00 3.3 0.4 4.6 2.3 3.4 0.4 4.6 2.3 0.4 0 0.4 0.4 69 7 67 305 0 0 0 0 -12.3 0.2 -12.1 -12.9 04/05/2005 15:50:00 4 0.5 4.9 2.3 4 0.5 4.9 2.6 0.4 0 0.4 0.4 50 8 49 305 0 0 0 0 -13.6 0.4 -12.5 -14.3 04/05/2005 16:00:00 4.1 0.5 5.3 3 4.1 0.4 5.3 3 0.4 0 0.4 0.4 60 7 67 305 0 0 0 0 -13.7 0.1 -13.3 -14.1 04/05/2005 16:10:00 4.2 0.4 4.9 3 4.2 0.4 5.3 3 0.4 0 0.4 0.4 61 7 66 305 0 0 0 0 -13.7 0.2 -13.3 -14.3 04/05/2005 16:20:00 4.2 0.5 5.3 3 4 0.5 5.3 3 0.4 0 0.4 0.4 64 6 77 305 0 0 0 0 -13.3 0.2 -12.9 -13.7 04/05/2005 16:30:00 4.2 0.5 6.1 3.4 4.2 0.5 6.1 3.4 0.4 0 0.4 0.4 65 5 62 305 0 0 0 0 -13.3 0.1 -12.9 -13.7 04/05/2005 16:40:00 4.7 0.5 5.7 3.8 4.7 0.5 6.1 3.8 0.4 0 0.4 0.4 56 7 56 305 0 0 0 0 -13.8 0.2 -13.1 -14.3 04/05/2005 16:50:00 4.4 0.4 5.7 3.4 4.4 0.4 5.3 3.4 0.4 0 0.4 0.4 60 6 50 305 0 0 0 0 -13.6 0.1 -13.3 -14.1 04/05/2005 17:00:00 4.8 0.5 6.5 3.8 4.7 0.5 6.1 3.8 0.4 0 0.4 0.4 56 7 58 305 0 0 0 0 -13.6 0.2 -13.3 -14.3 04/05/2005 17:10:00 5.1 0.6 6.5 3.8 5.1 0.6 6.5 3.8 0.4 0 0.4 0.4 54 8 62 305 0 0 0 0 -13.9 0.1 -13.7 -14.3 04/05/2005 17:20:00 5.2 0.4 6.5 3.8 5.3 0.4 6.1 4.2 0.4 0 0.4 0.4 53 5 57 305 0 0 0 0 -14.2 0 -13.9 -14.3 04/05/2005 17:30:00 5.2 0.4 6.1 3.8 5.2 0.5 6.5 3.8 0.4 0 0.4 0.4 52 4 54 305 0 0 0 0 -14 0.1 -13.7 -14.3 04/05/2005 17:40:00 5.5 0.4 6.5 4.2 5.5 0.5 6.5 4.2 0.4 0 0.4 0.4 46 3 48 305 0 0 0 0 -14.2 0 -13.9 -14.3 04/05/2005 17:50:00 5.7 0.4 6.5 4.2 5.8 0.5 6.5 4.2 0.4 0 0.4 0.4 49 4 48 305 0 0 0 0 -14.3 0 -14.1 -14.4 04/05/2005 18:00:00 6 0.4 6.8 4.9 5.9 0.4 7.2 4.9 0.4 0 0.4 0.4 46 5 41 305 0 0 0 0 -14.5 0.1 -14.3 -14.8 04/05/2005 18:10:00 6 0.4 6.8 5.3 6.1 0.4 6.8 4.9 0.4 0 0.4 0.4 48 3 50 305 0 0 0 0 -14.6 0.1 -14.3 -14.8 04/05/2005 18:20:00 5.3 0.4 6.5 4.2 5.3 0.5 6.5 4.2 0.4 0 0.4 0.4 43 6 39 305 0 0 0 0 -14.7 0.1 -14.3 -14.8 04/05/2005 18:30:00 5.5 0.5 6.8 4.2 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 45 5 43 305 0 0 0 0 -14.4 0 -14.3 -14.6 04/05/2005 18:40:00 5.5 0.6 6.5 4.2 5.5 0.6 6.8 4.2 0.4 0 0.4 0.4 49 5 59 305 0 0 0 0 -14.8 0.1 -14.4 -15 04/05/2005 18:50:00 5.8 0.4 6.8 4.6 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 49 4 55 305 0 0 0 0 -15 0 -14.6 -15 04/05/2005 19:00:00 5.5 0.5 7.2 4.6 5.5 0.5 6.8 4.6 0.4 0 0.4 0.4 52 4 51 305 0 0 0 0 -15.1 0 -14.8 -15.2 04/05/2005 19:10:00 6.2 0.5 7.6 4.6 6.2 0.5 7.2 4.9 0.4 0 0.4 0.4 52 3 55 305 0 0 0 0 -15.2 0 -15 -15.2 04/05/2005 19:20:00 6.3 0.5 7.6 4.9 6.2 0.6 7.6 4.9 0.4 0 0.4 0.4 53 3 52 305 0 0 0 0 -15.2 0.1 -15 -15.6 04/05/2005 19:30:00 7 0.5 8 5.7 6.9 0.5 8 5.7 0.4 0 0.4 0.4 51 3 61 305 0 0 0 0 -15.6 0.1 -15.2 -15.8 04/05/2005 19:40:00 7.4 0.5 8.4 6.1 7.3 0.5 8.4 6.1 0.4 0 0.4 0.4 51 3 54 305 0 0 0 0 -15.6 0 -15.4 -15.8 04/05/2005 19:50:00 7.3 0.4 8 6.1 7.2 0.5 8.4 6.1 0.4 0 0.4 0.4 52 3 54 305 0 0 0 0 -15.8 0 -15.6 -15.8 04/05/2005 20:00:00 7.3 0.4 8 6.1 7.2 0.5 8 5.7 0.4 0 0.4 0.4 52 3 56 305 0 0 0 0 -15.7 0.1 -15.6 -15.8 04/05/2005 20:10:00 6.6 0.5 7.6 5.3 6.5 0.6 7.6 4.9 0.4 0 0.4 0.4 52 3 54 305 0 0 0 0 -15.8 0 -15.6 -16 04/05/2005 20:20:00 6.9 0.5 8 5.3 6.8 0.5 8 5.3 0.4 0 0.4 0.4 52 3 52 305 0 0 0 0 -15.8 0 -15.6 -16 04/05/2005 20:30:00 7.1 0.5 8 5.7 7 0.5 8 5.7 0.4 0 0.4 0.4 52 3 56 305 0 0 0 0 -15.9 0 -15.8 -16 04/05/2005 20:40:00 7.2 0.6 8.4 5.7 7.1 0.6 8 5.7 0.4 0 0.4 0.4 51 3 50 305 0 0 0 0 -16 0 -16 -16.2 04/05/2005 20:50:00 7.3 0.4 8 6.1 7.2 0.4 8.4 6.1 0.4 0 0.4 0.4 51 3 54 305 0 0 0 0 -16.1 0 -16 -16.2 04/05/2005 21:00:00 7.3 0.5 8.4 6.1 7.2 0.6 8.4 6.1 0.4 0 0.4 0.4 50 4 49 305 0 0 0 0 -16.1 0 -16 -16.2 04/05/2005 21:10:00 7.6 0.6 9.1 6.1 7.4 0.6 8.8 6.1 0.4 0 0.4 0.4 49 4 45 305 0 0 0 0 -16.2 0 -16 -16.4 04/05/2005 21:20:00 7.4 0.5 8.8 6.1 7.3 0.6 8.8 5.7 0.4 0 0.4 0.4 50 4 48 305 0 0 0 0 -16.3 0 -16 -16.4 04/05/2005 21:30:00 7.2 0.5 8.4 6.1 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 53 4 51 305 1 0 0 0 -16.3 0 -16.2 -16.4 04/05/2005 21:40:00 6.9 0.5 8.4 5.3 6.8 0.5 8.4 5.3 0.4 0 0.4 0.4 50 4 51 305 1 0 1 0 -16.3 0 -16.2 -16.6 04/05/2005 21:50:00 6.9 0.4 8 5.7 6.7 0.4 7.6 5.7 0.4 0 0.4 0.4 54 4 54 305 1 0 1 0 -16.4 0 -16 -16.6 04/05/2005 22:00:00 7 0.5 8 5.7 6.8 0.5 8 5.3 0.4 0 0.4 0.4 53 3 48 305 1 0 1 0 -16.5 0 -16.4 -16.6 04/05/2005 22:10:00 6.9 0.5 8 5.7 6.7 0.5 8 5.3 0.4 0 0.4 0.4 52 4 51 305 1 0 1 0 -16.6 0 -16.4 -16.7 04/05/2005 22:20:00 6.7 0.5 7.6 5.7 6.6 0.5 7.6 5.3 0.4 0 0.4 0.4 52 4 48 305 1 0 1 0 -16.5 0 -16.4 -16.7 04/05/2005 22:30:00 6.7 0.5 7.6 4.6 6.6 0.5 7.6 4.9 0.4 0 0.4 0.4 52 3 52 305 1 0 1 0 -16.5 0 -16.4 -16.6 04/05/2005 22:40:00 6.8 0.6 8 5.3 6.6 0.5 7.6 5.3 0.4 0 0.4 0.4 51 4 47 305 1 0 1 0 -16.6 0 -16.4 -16.7 04/05/2005 22:50:00 6.7 0.4 7.6 5.7 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 52 4 45 305 1 0 1 0 -16.7 0 -16.6 -16.9 04/05/2005 23:00:00 6.2 0.4 7.2 4.9 6.1 0.4 7.2 5.3 0.4 0 0.4 0.4 53 4 54 305 1 0 1 0 -16.8 0 -16.6 -16.9 04/05/2005 23:10:00 5.3 0.5 6.5 3.8 5.1 0.5 6.1 4.2 0.4 0 0.4 0.4 55 5 58 305 1 0 1 0 -16.9 0 -16.7 -16.9 04/05/2005 23:20:00 6 0.6 7.6 4.6 5.9 0.6 7.6 4.2 0.4 0 0.4 0.4 52 5 55 305 1 0 1 0 -16.9 0 -16.9 -16.9 04/05/2005 23:30:00 6.4 0.5 7.2 5.3 6.3 0.5 7.6 4.9 0.4 0 0.4 0.4 52 4 47 305 1 0 1 0 -16.9 0 -16.9 -16.9 04/05/2005 23:40:00 6.6 0.4 7.6 5.3 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 53 3 52 305 1 0 1 0 -16.9 0 -16.9 -16.9 04/05/2005 23:50:00 7 0.4 7.6 5.7 6.8 0.4 8 5.3 0.4 0 0.4 0.4 51 3 53 305 2 0 2 0 -17 0 -16.9 -17.1 04/06/2005 00:00:00 7.1 0.4 8.4 5.7 6.9 0.4 8 5.7 0.4 0 0.4 0.4 52 3 52 305 2 0 1 0 -17.1 0.1 -16.6 -17.3 04/06/2005 00:10:00 6.7 0.6 8 5.3 6.6 0.5 8 4.9 0.4 0 0.4 0.4 51 4 52 305 2 0 2 0 -17.2 0 -16.9 -17.3 04/06/2005 00:20:00 6.9 0.5 8 5.7 6.8 0.5 8 5.3 0.4 0 0.4 0.4 52 3 48 305 2 0 2 0 -17.3 0.1 -16.9 -17.5 04/06/2005 00:30:00 7 0.4 8 5.7 6.9 0.5 8 5.3 0.4 0 0.4 0.4 53 4 50 305 2 0 2 0 -17.4 0 -16.9 -17.5 04/06/2005 00:40:00 6.7 0.5 8 5.3 6.6 0.6 7.6 5.3 0.4 0 0.4 0.4 54 3 54 305 2 0 2 0 -17.5 0 -16.9 -17.7 04/06/2005 00:50:00 6.7 0.7 8.4 4.9 6.6 0.7 8 4.9 0.4 0 0.4 0.4 51 4 50 305 2 0 2 0 -17.5 0 -16.9 -17.7 04/06/2005 01:00:00 6.6 0.4 7.6 5.3 6.4 0.4 7.6 4.9 0.4 0 0.4 0.4 50 3 53 305 2 0 2 0 -17.5 0 -16.9 -17.7 04/06/2005 01:10:00 6.8 0.5 7.6 5.3 6.7 0.5 7.6 4.9 0.4 0 0.4 0.4 50 4 48 305 2 0 2 0 -17.6 0 -16.9 -17.9 04/06/2005 01:20:00 6.9 0.5 8 5.7 6.8 0.5 8 5.7 0.4 0 0.4 0.4 48 4 46 305 2 0 2 0 -17.6 0 -16.9 -17.7 04/06/2005 01:30:00 7.5 1.1 9.5 5.7 7.5 1.1 9.5 5.3 0.4 0 0.4 0.4 37 5 37 305 2 0 2 0 -17.5 0.1 -16.9 -17.7 04/06/2005 01:40:00 8.2 0.6 9.9 6.5 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 34 5 34 305 2 0 2 0 -17.4 0 -16.9 -17.5 04/06/2005 01:50:00 8 0.9 9.9 5.7 7.8 1 9.9 5.7 0.4 0 0.4 0.4 38 7 38 305 2 0 2 0 -17.5 0.1 -16.9 -17.9 04/06/2005 02:00:00 7.9 0.8 10.3 6.1 7.9 0.8 10.3 6.5 0.4 0 0.4 0.4 43 5 33 305 2 0 2 0 -17.8 0 -17.1 -18.1 04/06/2005 02:10:00 7.7 0.9 10.3 6.1 7.7 1 9.9 5.3 0.4 0 0.4 0.4 35 7 46 305 2 0 2 0 -17.7 0 -16.9 -17.9 04/06/2005 02:20:00 8.6 1.1 11.5 6.5 8.5 1.2 11.5 6.1 0.4 0 0.4 0.4 32 6 27 305 2 0 2 0 -17.6 0 -16.9 -17.9 04/06/2005 02:30:00 9.6 0.8 11.1 7.2 9.4 1 11.5 6.8 0.4 0 0.4 0.4 31 5 28 305 2 0 2 0 -17.6 0 -17.1 -17.7 04/06/2005 02:40:00 9.8 0.8 11.5 7.6 9.7 0.9 11.5 6.8 0.4 0 0.4 0.4 32 6 30 305 2 0 2 0 -17.6 0 -17.1 -17.9 04/06/2005 02:50:00 10.3 0.6 11.8 8.4 10.2 0.7 12.2 8.4 0.4 0 0.4 0.4 33 4 38 305 2 0 2 0 -17.8 0 -17.3 -17.9 04/06/2005 03:00:00 10.3 0.8 12.2 8 10.2 0.9 12.2 7.6 0.4 0 0.4 0.4 32 4 33 305 2 0 2 0 -17.8 0.1 -17.5 -18.1 04/06/2005 03:10:00 10 0.8 11.8 7.6 9.9 0.9 11.8 7.6 0.4 0 0.4 0.4 31 5 33 305 2 0 2 0 -17.9 0 -17.7 -18.1 04/06/2005 03:20:00 10.6 0.8 12.6 8 10.6 0.9 12.6 8.4 0.4 0 0.4 0.4 32 5 36 305 2 0 2 0 -17.9 0 -17.7 -18.1 04/06/2005 03:30:00 10.2 0.9 12.6 7.6 10.1 1 12.2 7.6 0.4 0 0.4 0.4 33 5 33 305 2 0 2 0 -17.9 0 -17.7 -18.1 04/06/2005 03:40:00 10.3 0.8 11.8 8 10.3 0.9 12.6 7.6 0.4 0 0.4 0.4 35 5 40 305 2 0 2 0 -18 0 -17.9 -18.1 04/06/2005 03:50:00 10.7 1.1 13 7.6 10.6 1.1 13.3 7.6 0.4 0 0.4 0.4 31 6 27 305 2 0 2 0 -18 0 -17.9 -18.1 04/06/2005 04:00:00 11.5 1 13.3 8.4 11.2 1.1 13.3 7.6 0.4 0 0.4 0.4 30 4 35 305 2 0 2 0 -18.1 0 -17.7 -18.1 04/06/2005 04:10:00 10.5 1.3 13.7 7.2 10.3 1.4 14.1 7.2 0.4 0 0.4 0.4 32 4 29 305 2 0 2 0 -18.1 0.1 -17.5 -18.4 04/06/2005 04:20:00 11.4 0.9 13.3 9.5 11.3 1 14.5 8.8 0.4 0 0.4 0.4 33 4 34 305 2 0 2 0 -18.4 0.1 -17.9 -18.4 04/06/2005 04:30:00 11 1.1 13.3 7.6 11 1.1 13 8 0.4 0 0.4 0.4 33 5 31 305 2 0 2 0 -18.5 0 -18.1 -18.4 04/06/2005 04:40:00 10.7 0.7 12.6 8.4 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 34 4 36 305 2 0 2 0 -18.5 0 -18.1 -18.4 04/06/2005 04:50:00 11.1 1.1 13.3 8.4 11 1.2 13.3 8 0.4 0 0.4 0.4 34 4 35 305 2 0 2 0 -18.6 0 -18.1 -18.6 04/06/2005 05:00:00 11.4 0.7 13 9.5 11.4 0.8 13.3 9.1 0.4 0 0.4 0.4 32 4 29 305 2 0 2 0 -18.6 0 -18.1 -18.8 04/06/2005 05:10:00 11.3 1.2 13.7 8.8 11.1 1.2 13.7 8.4 0.4 0 0.4 0.4 29 5 25 305 2 0 2 0 -18.6 0 -18.4 -18.8 04/06/2005 05:20:00 10.8 1 13.3 8 10.7 1.1 13 7.2 0.4 0 0.4 0.4 32 5 28 305 2 0 2 0 -18.7 0 -18.4 -19 04/06/2005 05:30:00 10.7 0.9 13 8.4 10.6 1 12.6 8 0.4 0 0.4 0.4 34 5 39 305 2 0 1 0 -18.8 0 -18.4 -19 04/06/2005 05:40:00 11.3 1.2 14.1 8.8 11.2 1.2 14.1 8.4 0.4 0 0.4 0.4 30 6 27 305 2 0 2 0 -18.7 0.1 -18.4 -19 04/06/2005 05:50:00 11.1 1 13.7 8.4 10.9 1.1 13.7 8 0.4 0 0.4 0.4 29 6 25 305 2 0 2 0 -18.8 0.1 -18.6 -19 04/06/2005 06:00:00 11.2 1 13.7 8.4 11 1.1 14.5 8 0.4 0 0.4 0.4 35 5 31 305 2 0 2 0 -18.9 0.1 -18.2 -19 04/06/2005 06:10:00 10.7 0.8 12.6 8.8 10.6 1 13 8 0.4 0 0.4 0.4 35 5 40 305 2 0 2 0 -19.1 0 -18.8 -19.2 04/06/2005 06:20:00 11.5 0.9 13.7 8.8 11.5 1 13.3 8.4 0.4 0 0.4 0.4 38 4 40 305 2 0 2 0 -19.1 0 -19 -19.2 04/06/2005 06:30:00 11.7 0.7 13.3 9.5 11.7 0.8 13.3 9.5 0.4 0 0.4 0.4 37 3 32 305 2 0 2 0 -19.2 0 -19 -19.3 04/06/2005 06:40:00 11.9 0.9 14.1 9.1 11.9 1 13.7 9.1 0.4 0 0.4 0.4 36 5 38 305 2 0 2 0 -19.2 0 -19 -19.3 04/06/2005 06:50:00 11.8 0.9 14.1 9.1 11.8 1 13.7 9.1 0.4 0 0.4 0.4 37 5 41 305 2 0 2 0 -19.2 0 -19 -19.5 04/06/2005 07:00:00 11.5 0.8 13.3 9.5 11.4 0.9 13.7 9.1 0.4 0 0.4 0.4 38 4 42 305 2 0 2 0 -19.2 0 -19 -19.3 04/06/2005 07:10:00 10.7 1.1 13.3 8 10.6 1.2 13.7 7.6 0.4 0 0.4 0.4 32 5 23 305 2 0 2 0 -19.1 0.1 -18.8 -19.3 04/06/2005 07:20:00 11.9 1.2 14.5 8.4 11.8 1.2 14.9 8.8 0.4 0 0.4 0.4 31 6 33 305 2 0 2 0 -19 0.1 -18.8 -19 04/06/2005 07:30:00 11.8 0.8 14.5 9.9 11.8 0.9 14.1 8.8 0.4 0 0.4 0.4 37 6 17 305 2 0 2 0 -19.1 0 -18.8 -19.2 04/06/2005 07:40:00 13.5 1.5 16.1 9.1 13.4 1.7 16.4 9.1 0.4 0 0.4 0.4 33 5 31 305 2 0 2 0 -19 0 -18.8 -19.2 04/06/2005 07:50:00 13.3 1.2 16.1 9.5 13.3 1.2 16.4 9.9 0.4 0 0.4 0.4 34 5 35 305 2 0 2 0 -19.1 0 -19 -19.2 04/06/2005 08:00:00 13.1 1 15.3 9.9 13 1.2 15.3 9.1 0.4 0 0.4 0.4 37 4 36 305 2 0 2 0 -19.1 0 -18.6 -19.3 04/06/2005 08:10:00 13.3 1.4 16.4 9.9 13.2 1.4 16.4 9.5 0.4 0 0.4 0.4 31 6 24 305 2 0 2 0 -19 0.1 -18.4 -19.2 04/06/2005 08:20:00 12.4 1.2 15.6 9.1 12.2 1.2 16.1 9.5 0.4 0 0.4 0.4 33 6 41 305 2 0 2 0 -19 0.1 -18.4 -19 04/06/2005 08:30:00 12.5 1 14.9 9.5 12.5 1.1 15.3 9.5 0.4 0 0.4 0.4 38 5 45 305 2 0 2 0 -19 0.1 -18.4 -19.2 04/06/2005 08:40:00 13.7 1.2 16.4 10.3 13.7 1.3 16.4 9.9 0.4 0 0.4 0.4 38 4 36 305 2 0 2 0 -19.1 0 -18.4 -19.2 04/06/2005 08:50:00 13.7 1 16.4 10.7 13.8 1.2 16.8 10.3 0.4 0 0.4 0.4 38 4 39 305 2 0 2 0 -19.1 0 -18.8 -19.2 04/06/2005 09:00:00 14.3 1 17.2 11.8 14.2 1.1 17.2 9.9 0.4 0 0.4 0.4 38 5 34 305 2 0 2 0 -19.1 0 -18.6 -19.2 04/06/2005 09:10:00 14.2 0.8 15.6 11.8 14.3 0.9 16.4 11.5 0.4 0 0.4 0.4 38 3 36 305 2 0 2 0 -19.1 0 -18.8 -19.2 04/06/2005 09:20:00 13 1.1 15.3 9.9 13.1 1.2 15.6 9.9 0.4 0 0.4 0.4 39 4 39 305 2 0 2 0 -19 0.1 -18.8 -19 04/06/2005 09:30:00 12.9 0.8 14.5 10.3 13 1 14.9 9.5 0.4 0 0.4 0.4 39 4 33 305 3 0 2 0 -19 0 -18.8 -19 04/06/2005 09:40:00 13.1 1 15.6 10.7 13.1 1.1 16.1 9.9 0.4 0 0.4 0.4 36 5 37 305 3 0 3 0 -18.8 0 -18.6 -19 04/06/2005 09:50:00 12.9 1 15.3 10.3 12.9 1.1 15.6 9.9 0.4 0 0.4 0.4 39 5 35 305 3 0 2 0 -18.8 0 -18.6 -19 04/06/2005 10:00:00 12.6 1 15.6 10.3 12.7 1.1 15.3 9.9 0.4 0 0.4 0.4 38 5 35 305 3 0 3 0 -18.7 0.1 -18.1 -18.8 04/06/2005 10:10:00 12.6 1.1 14.9 9.5 12.5 1.1 15.3 9.1 0.4 0 0.4 0.4 36 5 36 305 3 0 3 0 -18.6 0 -18.1 -18.6 04/06/2005 10:20:00 11.8 1 14.5 9.1 11.8 1.2 14.5 8.8 0.4 0 0.4 0.4 37 5 42 305 3 0 3 0 -18.5 0 -17.9 -18.6 04/06/2005 10:30:00 12.3 0.9 14.9 9.9 12.3 1 14.9 9.9 0.4 0 0.4 0.4 35 6 27 305 3 0 3 0 -18.4 0.1 -17.9 -18.4 04/06/2005 10:40:00 12.5 1.2 14.9 9.1 12.5 1.3 15.6 9.9 0.4 0 0.4 0.4 33 4 30 305 3 0 3 0 -18.2 0 -17.7 -18.4 04/06/2005 10:50:00 12.1 1 14.1 9.5 12.2 1 14.5 9.5 0.4 0 0.4 0.4 37 5 32 305 3 0 3 0 -18.2 0.1 -18.1 -18.4 04/06/2005 11:00:00 12.8 0.9 14.5 9.9 12.9 1 14.9 10.3 0.4 0 0.4 0.4 35 4 35 305 3 0 3 0 -18.1 0 -18.1 -18.2 04/06/2005 11:10:00 12.8 1.1 15.6 9.5 12.7 1.1 14.9 9.5 0.4 0 0.4 0.4 31 6 31 305 3 0 3 0 -18.1 0 -17.9 -18.2 04/06/2005 11:20:00 12.2 1.1 14.1 9.1 12 1.2 14.5 9.1 0.4 0 0.4 0.4 28 4 25 305 3 0 3 0 -18 0 -17.9 -18.2 04/06/2005 11:30:00 11.3 1.2 13.7 8.8 11.1 1.2 13.7 8.8 0.4 0 0.4 0.4 29 6 32 305 3 0 3 0 -17.7 0 -17.5 -18.1 04/06/2005 11:40:00 11.7 1.1 14.9 8.4 11.6 1.2 15.3 8.4 0.4 0 0.4 0.4 29 5 31 305 2 0 2 0 -17.6 0.1 -17.3 -17.9 04/06/2005 11:50:00 11.4 1 13.7 9.1 11.2 1 13.7 8.8 0.4 0 0.4 0.4 27 5 32 305 2 0 2 0 -17.5 0.1 -16.9 -17.7 04/06/2005 12:00:00 11.2 1.1 13.7 8 11.1 1.1 13.3 8.4 0.4 0 0.4 0.4 27 6 32 305 2 0 2 0 -17.2 0 -16.9 -17.3 04/06/2005 12:10:00 10.9 0.9 13 8.8 10.9 1 13.3 8.8 0.4 0 0.4 0.4 25 5 26 305 2 0 2 0 -17.2 0.1 -16.9 -17.5 04/06/2005 12:20:00 11.9 1.3 14.5 8.8 11.9 1.3 14.9 9.1 0.4 0 0.4 0.4 20 5 20 305 1 0 1 0 -17.1 0.1 -16.6 -17.3 04/06/2005 12:30:00 13.3 1.1 15.6 9.9 13.2 1.3 15.6 9.1 0.4 0 0.4 0.4 23 4 18 305 1 0 1 0 -17.4 0 -16.9 -17.5 04/06/2005 12:40:00 13.1 0.8 14.9 9.9 13 0.9 14.9 9.9 0.4 0 0.4 0.4 23 5 23 305 1 0 1 0 -17.3 0.1 -16.9 -17.5 04/06/2005 12:50:00 13.3 1.1 16.1 10.7 13.2 1.2 16.4 9.9 0.4 0 0.4 0.4 22 5 26 305 1 0 1 0 -17.2 0.1 -16.9 -17.5 04/06/2005 13:00:00 13.1 0.9 15.3 9.9 13 1 15.6 9.9 0.4 0 0.4 0.4 24 5 32 305 1 0 1 0 -17.1 0.1 -16.9 -17.5 04/06/2005 13:10:00 12.1 1.1 14.1 9.1 12 1.2 14.5 8.8 0.4 0 0.4 0.4 22 5 26 305 1 0 1 0 -16.7 0.2 -16.4 -17.1 04/06/2005 13:20:00 12.6 1.1 15.3 9.5 12.5 1.1 15.3 9.5 0.4 0 0.4 0.4 22 5 26 305 1 0 1 0 -17 0.1 -16.6 -17.3 04/06/2005 13:30:00 13.2 1.1 15.6 9.9 13.1 1.1 16.1 10.3 0.4 0 0.4 0.4 20 5 15 305 1 0 1 0 -17.1 0 -16.9 -17.3 04/06/2005 13:40:00 13.5 1.1 15.6 10.7 13.4 1.1 15.6 10.3 0.4 0 0.4 0.4 21 4 19 305 1 0 1 0 -17.1 0.1 -16.9 -17.3 04/06/2005 13:50:00 12.7 1.2 14.9 8.4 12.7 1.2 15.3 8.4 0.4 0 0.4 0.4 21 4 18 305 1 0 1 0 -17.1 0.1 -16.6 -17.3 04/06/2005 14:00:00 13.6 1.1 15.6 9.5 13.5 1.2 16.1 9.5 0.4 0 0.4 0.4 21 4 18 305 1 0 1 0 -16.8 0 -16.6 -16.9 04/06/2005 14:10:00 13.5 1.3 16.4 10.7 13.4 1.3 16.4 10.7 0.4 0 0.4 0.4 24 5 27 305 1 0 1 0 -16.9 0 -16.6 -17.1 04/06/2005 14:20:00 12.6 1 14.5 9.1 12.4 1 14.5 9.1 0.4 0 0.4 0.4 26 6 21 305 1 0 1 0 -16.7 0.1 -16.4 -16.9 04/06/2005 14:30:00 12.1 1.2 14.5 9.1 12 1.3 14.9 8.8 0.4 0 0.4 0.4 23 5 30 305 1 0 1 0 -16.5 0.1 -16.2 -16.9 04/06/2005 14:40:00 12.5 1 14.5 9.9 12.4 1 14.9 9.5 0.4 0 0.4 0.4 22 5 25 305 1 0 1 0 -16.6 0 -16.4 -16.9 04/06/2005 14:50:00 11.6 1.1 13.7 8.4 11.5 1.1 14.1 8.8 0.4 0 0.4 0.4 22 5 22 305 1 0 1 0 -16.4 0 -16 -16.7 04/06/2005 15:00:00 11.1 1 13.3 8.4 11 1.1 13.7 8 0.4 0 0.4 0.4 25 6 29 305 1 0 1 0 -16.1 0 -15.8 -16.2 04/06/2005 15:10:00 11.2 1.1 13.3 7.6 11.1 1.2 13.7 7.6 0.4 0 0.4 0.4 22 5 17 305 1 0 1 0 -16 0.1 -15.6 -16.4 04/06/2005 15:20:00 11.7 1 13.7 8.4 11.7 1 14.1 8.8 0.4 0 0.4 0.4 22 6 24 305 1 0 1 0 -15.9 0 -15.6 -16.2 04/06/2005 15:30:00 11 1.2 13.3 7.6 10.8 1.2 13.3 8 0.4 0 0.4 0.4 21 6 25 305 1 0 1 0 -15.8 0.1 -15.4 -16 04/06/2005 15:40:00 10.8 1 13 8 10.8 1 12.6 8 0.4 0 0.4 0.4 24 5 24 305 1 0 0 0 -15.8 0 -15.4 -16 04/06/2005 15:50:00 11 1 13 8.4 10.9 1 13 8.4 0.4 0 0.4 0.4 23 7 20 305 1 0 1 0 -15.7 0.1 -15 -15.8 04/06/2005 16:00:00 11.6 1.2 13.7 8 11.6 1.2 14.5 7.6 0.4 0 0.4 0.4 20 5 27 305 1 0 0 0 -15.6 0.1 -15.2 -15.8 04/06/2005 16:10:00 11.9 1.2 14.9 8.8 11.9 1.2 14.9 8.8 0.4 0 0.4 0.4 19 5 29 305 1 0 1 0 -15.7 0.1 -15.2 -15.8 04/06/2005 16:20:00 11.9 0.9 14.1 8.4 11.8 1 14.5 9.1 0.4 0 0.4 0.4 17 6 16 305 1 0 1 0 -15.7 0.1 -15.2 -15.8 04/06/2005 16:30:00 11.3 0.9 13.3 8.4 11.2 1 13.3 8.8 0.4 0 0.4 0.4 21 5 24 305 1 0 1 0 -15.6 0.1 -15 -15.8 04/06/2005 16:40:00 11 1 13 8.4 10.9 1 13 8.4 0.4 0 0.4 0.4 18 5 16 305 1 0 1 0 -15.4 0 -15 -15.6 04/06/2005 16:50:00 11.9 1.1 14.5 8.8 11.8 1.2 14.1 8.4 0.4 0 0.4 0.4 16 6 14 305 1 0 1 0 -15.3 0 -14.8 -15.6 04/06/2005 17:00:00 11.6 1 13.7 9.1 11.5 1.1 13.7 8.8 0.4 0 0.4 0.4 14 5 12 305 1 0 1 0 -15.4 0 -15 -15.6 04/06/2005 17:10:00 12.3 1 14.9 9.5 12.4 1 14.5 9.1 0.4 0 0.4 0.4 8 4 9 305 1 0 1 0 -15.7 0.1 -15.2 -15.8 04/06/2005 17:20:00 12.5 0.9 14.5 9.5 12.5 1 14.9 10.3 0.4 0 0.4 0.4 8 4 6 305 1 0 1 0 -15.8 0 -15.6 -16 04/06/2005 17:30:00 11.8 1 14.1 8.8 11.9 1 14.1 8.4 0.4 0 0.4 0.4 7 5 1 305 1 0 1 0 -15.9 0 -15.6 -16 04/06/2005 17:40:00 11.9 1.2 14.5 8.8 12 1.2 14.9 8.4 0.4 0 0.4 0.4 9 4 1 305 1 0 1 0 -16 0 -15.8 -16.2 04/06/2005 17:50:00 11.3 1.2 14.1 7.6 11.3 1.2 14.1 8 0.4 0 0.4 0.4 10 5 12 305 1 0 1 0 -15.9 0 -15.8 -16 04/06/2005 18:00:00 11.9 1.2 14.5 8.4 11.8 1.2 14.1 8.4 0.4 0 0.4 0.4 8 5 358 305 2 0 2 0 -15.8 0 -15.6 -16 04/06/2005 18:10:00 11.7 1 13.7 9.1 11.8 1.1 14.5 9.1 0.4 0 0.4 0.4 8 5 5 305 2 0 2 0 -15.8 0 -15.6 -16 04/06/2005 18:20:00 12.1 1 14.5 9.5 12.1 1 15.3 9.9 0.4 0 0.4 0.4 8 5 9 305 2 0 2 0 -15.9 0 -15.6 -16.2 04/06/2005 18:30:00 12.2 1 14.5 9.1 12.2 1.1 14.5 9.1 0.4 0 0.4 0.4 7 5 4 305 2 0 2 0 -16 0 -15.8 -16.2 04/06/2005 18:40:00 12.2 1 14.9 9.5 12.2 1 15.3 9.9 0.4 0 0.4 0.4 8 5 4 305 3 0 3 0 -16 0 -15.8 -16.2 04/06/2005 18:50:00 12.3 1.1 14.9 9.1 12.3 1.2 14.5 9.1 0.4 0 0.4 0.4 8 5 6 305 3 0 3 0 -16.1 0.1 -15.8 -16.4 04/06/2005 19:00:00 10.9 1.1 13.7 8.4 10.9 1.2 14.1 7.6 0.4 0 0.4 0.4 10 5 10 305 3 0 3 0 -16.3 0 -16 -16.6 04/06/2005 19:10:00 11.8 1.2 14.5 8 11.8 1.3 14.9 8 0.4 0 0.4 0.4 8 5 9 305 3 0 3 0 -16.4 0 -16.2 -16.6 04/06/2005 19:20:00 12.1 1.2 14.5 9.1 12 1.1 14.9 8.8 0.4 0 0.4 0.4 11 5 12 305 3 0 3 0 -16.6 0 -16.4 -16.9 04/06/2005 19:30:00 11.8 1.3 14.9 8.4 11.8 1.3 14.1 8 0.4 0 0.4 0.4 10 5 4 305 3 0 3 0 -16.7 0.1 -16.4 -16.9 04/06/2005 19:40:00 12.3 1 14.9 9.5 12.2 1 14.9 9.5 0.4 0 0.4 0.4 9 4 5 305 3 0 3 0 -16.8 0 -16.6 -16.9 04/06/2005 19:50:00 12.3 0.9 14.5 9.5 12.3 1 15.3 9.1 0.4 0 0.4 0.4 10 5 9 305 3 0 3 0 -16.9 0 -16.9 -16.9 04/06/2005 20:00:00 11.9 1.3 14.9 9.1 11.9 1.3 14.9 8.4 0.4 0 0.4 0.4 9 5 12 305 3 0 3 0 -16.9 0 -16.4 -16.9 04/06/2005 20:10:00 11.9 1.1 14.1 9.5 11.9 1.1 14.5 9.1 0.4 0 0.4 0.4 8 5 11 305 3 0 3 0 -16.9 0 -16.4 -16.9 04/06/2005 20:20:00 12 1.2 14.5 8.4 11.9 1.2 14.9 8.8 0.4 0 0.4 0.4 9 5 4 305 3 0 3 0 -17 0 -16.6 -17.3 04/06/2005 20:30:00 12.2 1.1 14.1 8.8 12.1 1.2 14.9 8.8 0.4 0 0.4 0.4 13 5 10 305 3 0 3 0 -17.3 0.1 -16.9 -17.5 04/06/2005 20:40:00 11.9 1 13.7 9.1 11.9 1.1 14.5 9.5 0.4 0 0.4 0.4 10 5 13 305 3 0 3 0 -17.2 0 -16.9 -17.3 04/06/2005 20:50:00 12.2 1 14.5 9.5 12.2 1 14.9 8.8 0.4 0 0.4 0.4 9 4 8 305 3 0 3 0 -17.2 0 -16.9 -17.3 04/06/2005 21:00:00 11.2 1.2 14.9 7.6 11.1 1.3 14.5 7.2 0.4 0 0.4 0.4 10 5 13 305 3 0 3 0 -17.1 0 -16.9 -17.3 04/06/2005 21:10:00 12.1 1 14.9 9.5 12.1 1.1 14.9 9.5 0.4 0 0.4 0.4 9 6 9 305 3 0 3 0 -17.2 0 -16.6 -17.3 04/06/2005 21:20:00 11.7 1.2 14.1 8.4 11.7 1.2 14.1 8.4 0.4 0 0.4 0.4 8 6 8 305 3 0 3 0 -17.2 0 -16.9 -17.3 04/06/2005 21:30:00 11.9 1 14.1 9.1 11.8 1 14.5 9.1 0.4 0 0.4 0.4 9 5 8 305 3 0 3 0 -17.3 0.1 -17.1 -17.5 04/06/2005 21:40:00 11.3 1 13.7 8.4 11.4 1 14.1 9.1 0.4 0 0.4 0.4 7 6 359 305 3 0 3 0 -17.4 0 -17.1 -17.5 04/06/2005 21:50:00 11.5 1 13.7 8.4 11.5 1 13.7 8.8 0.4 0 0.4 0.4 7 5 11 305 3 0 3 0 -17.4 0 -17.3 -17.5 04/06/2005 22:00:00 11.4 1.1 14.1 8 11.3 1.1 14.1 8.4 0.4 0 0.4 0.4 8 5 12 305 3 0 3 0 -17.3 0 -16.9 -17.5 04/06/2005 22:10:00 12.3 1 14.5 9.5 12.2 1 14.5 9.9 0.4 0 0.4 0.4 12 4 12 305 3 0 3 0 -17.4 0 -17.1 -17.5 04/06/2005 22:20:00 11.4 1 13.7 8.4 11.3 1.1 13.3 8.8 0.4 0 0.4 0.4 10 5 5 305 3 0 3 0 -17.3 0 -17.1 -17.5 04/06/2005 22:30:00 11.7 1 13.7 8.8 11.6 1 13.7 8.8 0.4 0 0.4 0.4 9 4 10 305 3 0 3 0 -17.3 0 -17.1 -17.3 04/06/2005 22:40:00 12.3 0.9 14.1 9.1 12.3 1 14.9 9.9 0.4 0 0.4 0.4 8 4 3 305 3 0 3 0 -17.3 0.1 -16.9 -17.5 04/06/2005 22:50:00 12 0.8 13.7 9.9 12.1 0.8 13.7 9.5 0.4 0 0.4 0.4 10 4 7 305 3 0 3 0 -17.4 0 -17.1 -17.5 04/06/2005 23:00:00 11.6 1 14.1 8.8 11.4 1 14.9 8.8 0.4 0 0.4 0.4 12 5 14 305 3 0 3 0 -17.4 0 -16.9 -17.5 04/06/2005 23:10:00 12 1.1 14.5 8.8 11.8 1.1 14.5 9.1 0.4 0 0.4 0.4 14 5 9 305 3 0 3 0 -17.5 0 -17.3 -17.5 04/06/2005 23:20:00 11.8 1 13.7 9.1 11.6 1.1 14.1 8.8 0.4 0 0.4 0.4 15 4 11 305 3 0 3 0 -17.5 0 -17.5 -17.7 04/06/2005 23:30:00 11.3 1 13 8.8 11.1 1 13.3 8.4 0.4 0 0.4 0.4 15 4 24 305 3 0 3 0 -17.5 0 -17.5 -17.7 04/06/2005 23:40:00 11.3 1.2 13.3 8 11.1 1.2 13.3 8 0.4 0 0.4 0.4 12 5 8 305 3 0 3 0 -17.5 0 -17.1 -17.7 04/06/2005 23:50:00 11.5 0.8 13.3 9.1 11.4 1 13.7 8.8 0.4 0 0.4 0.4 10 4 11 305 3 0 3 0 -17.5 0 -17.3 -17.5 04/07/2005 00:00:00 10.3 1.2 13 8 10.2 1.2 13.3 7.6 0.4 0 0.4 0.4 18 7 9 305 3 0 3 0 -17.4 0 -17.1 -17.5 04/07/2005 00:10:00 10 1.1 13 7.6 10 1.1 13.3 7.6 0.4 0 0.4 0.4 24 6 23 305 3 0 3 0 -17.4 0 -17.3 -17.5 04/07/2005 00:20:00 10.2 1 12.6 7.6 10.1 1 12.6 8 0.4 0 0.4 0.4 25 5 21 305 3 0 3 0 -17.5 0 -17.5 -17.7 04/07/2005 00:30:00 10.3 1 13 7.6 10.2 1 12.6 7.2 0.4 0 0.4 0.4 25 5 25 305 3 0 4 0 -17.6 0 -17.5 -17.7 04/07/2005 00:40:00 9.1 1 12.6 7.2 9 1 12.2 6.5 0.4 0 0.4 0.4 22 5 14 305 3 0 3 0 -17.4 0 -17.1 -17.7 04/07/2005 00:50:00 10.3 1.5 13.7 6.8 10.2 1.6 14.1 6.8 0.4 0 0.4 0.4 16 8 7 305 3 0 4 0 -17.2 0 -16.9 -17.5 04/07/2005 01:00:00 10 1.2 12.6 7.6 9.9 1.2 13 7.6 0.4 0 0.4 0.4 29 6 32 305 3 0 3 0 -17.5 0 -16.9 -17.9 04/07/2005 01:10:00 10.5 0.9 12.6 8 10.5 1 13.3 8 0.4 0 0.4 0.4 28 5 22 305 3 0 3 0 -17.6 0 -17.5 -17.9 04/07/2005 01:20:00 9.7 0.7 11.5 8 9.6 0.7 11.5 8 0.4 0 0.4 0.4 33 4 27 305 3 0 4 0 -17.8 0.1 -17.5 -18.1 04/07/2005 01:30:00 9.8 0.8 11.5 8 9.7 1 11.8 7.2 0.4 0 0.4 0.4 32 5 35 305 3 0 3 0 -17.8 0 -17.5 -18.1 04/07/2005 01:40:00 9.3 0.9 11.5 6.8 9.2 1 11.5 6.8 0.4 0 0.4 0.4 30 6 32 305 3 0 3 0 -17.8 0 -17.5 -18.1 04/07/2005 01:50:00 10.2 1 12.6 8 10.2 1.2 13 7.2 0.4 0 0.4 0.4 24 7 29 305 3 0 4 0 -17.5 0 -17.3 -17.7 04/07/2005 02:00:00 10.4 1.3 13 7.6 10.4 1.3 12.6 6.8 0.4 0 0.4 0.4 16 7 21 305 3 0 4 0 -17.4 0 -16.9 -17.5 04/07/2005 02:10:00 12.2 1.1 14.9 9.5 12.3 1.1 14.9 9.5 0.4 0 0.4 0.4 5 5 5 305 3 0 3 0 -17.5 0 -17.3 -17.5 04/07/2005 02:20:00 12.1 1.1 14.5 8.8 12.1 1.2 14.5 8.8 0.4 0 0.4 0.4 5 5 359 305 3 0 4 0 -17.5 0 -16.9 -17.5 04/07/2005 02:30:00 12.6 1 14.5 9.5 12.5 1.1 14.9 9.9 0.4 0 0.4 0.4 8 4 8 305 3 0 4 0 -17.5 0 -17.3 -17.7 04/07/2005 02:40:00 12.3 1 14.9 9.1 12.2 1.1 14.5 9.1 0.4 0 0.4 0.4 10 5 6 305 3 0 4 0 -17.6 0 -17.5 -17.7 04/07/2005 02:50:00 11.7 1.2 14.1 9.1 11.7 1.2 14.1 8.8 0.4 0 0.4 0.4 8 5 6 305 3 0 4 0 -17.6 0 -17.5 -17.9 04/07/2005 03:00:00 11.9 1.1 14.5 9.1 11.8 1.2 15.3 9.1 0.4 0 0.4 0.4 10 5 6 305 3 0 4 0 -17.5 0 -17.5 -17.7 04/07/2005 03:10:00 12.1 1.1 14.5 8.8 12 1.2 14.9 9.1 0.4 0 0.4 0.4 10 5 9 305 3 0 4 0 -17.5 0 -17.5 -17.7 04/07/2005 03:20:00 10.7 1.3 13.7 7.6 10.7 1.3 13.7 7.6 0.4 0 0.4 0.4 14 7 6 305 3 0 4 0 -17.5 0 -17.5 -17.7 04/07/2005 03:30:00 10.2 1 12.6 8 10.2 1 12.6 7.6 0.4 0 0.4 0.4 28 5 24 305 4 0 4 0 -17.7 0 -17.5 -18.1 04/07/2005 03:40:00 10.2 0.8 12.2 8.4 10.1 0.9 12.2 8 0.4 0 0.4 0.4 28 5 23 305 3 0 4 0 -17.8 0 -17.7 -18.1 04/07/2005 03:50:00 9.4 0.8 11.1 7.6 9.3 0.8 11.1 7.2 0.4 0 0.4 0.4 28 5 24 305 3 0 4 0 -17.9 0 -17.7 -18.1 04/07/2005 04:00:00 10 1.2 13.3 7.6 9.9 1.3 13.3 7.6 0.4 0 0.4 0.4 21 9 10 305 3 0 4 0 -17.8 0.1 -17.5 -18.1 04/07/2005 04:10:00 12 0.9 14.5 9.5 11.9 1 14.5 8.8 0.4 0 0.4 0.4 10 4 8 305 3 0 4 0 -17.6 0 -17.5 -17.7 04/07/2005 04:20:00 12.4 1 14.5 9.1 12.3 1 15.3 9.1 0.4 0 0.4 0.4 6 5 9 305 3 0 4 0 -17.7 0 -17.5 -17.9 04/07/2005 04:30:00 12.1 1.2 14.9 9.1 12 1.2 14.9 9.1 0.4 0 0.4 0.4 7 5 3 305 3 0 4 0 -17.7 0 -17.5 -18.1 04/07/2005 04:40:00 12.3 1 14.5 9.5 12.3 1.1 14.5 8.8 0.4 0 0.4 0.4 6 4 4 305 3 0 4 0 -17.8 0 -17.7 -18.1 04/07/2005 04:50:00 12.7 1 14.9 9.9 12.6 1 15.3 10.3 0.4 0 0.4 0.4 4 5 5 305 3 0 4 0 -18 0 -17.9 -18.1 04/07/2005 05:00:00 11.8 1.1 14.1 8.8 11.8 1.1 14.1 8.8 0.4 0 0.4 0.4 6 5 8 305 3 0 4 0 -17.9 0 -17.7 -18.1 04/07/2005 05:10:00 11.9 1.1 14.1 8.8 11.8 1 14.5 8.4 0.4 0 0.4 0.4 7 4 7 305 3 0 4 0 -17.9 0 -17.7 -18.1 04/07/2005 05:20:00 12.1 1.1 14.5 9.5 12.2 1.2 14.9 8.4 0.4 0 0.4 0.4 6 5 8 305 3 0 3 0 -17.9 0 -17.7 -18.1 04/07/2005 05:30:00 12.1 1 14.5 9.1 12.2 1 14.5 9.1 0.4 0 0.4 0.4 6 5 7 305 3 0 4 0 -17.8 0 -17.5 -18.1 04/07/2005 05:40:00 12.6 0.9 14.5 10.3 12.5 0.9 14.9 9.9 0.4 0 0.4 0.4 5 4 12 305 3 0 4 0 -17.7 0 -17.5 -17.9 04/07/2005 05:50:00 12.3 1.1 14.9 9.5 12.2 1.1 14.9 9.5 0.4 0 0.4 0.4 5 4 0 305 3 0 4 0 -17.7 0 -17.5 -17.9 04/07/2005 06:00:00 11.8 1.1 14.5 9.1 11.7 1.1 14.5 9.1 0.4 0 0.4 0.4 7 5 7 305 4 0 4 0 -17.5 0 -17.5 -17.7 04/07/2005 06:10:00 12.6 1.2 14.5 8.8 12.5 1.2 14.9 8.8 0.4 0 0.4 0.4 6 5 7 305 4 0 4 0 -17.5 0 -17.3 -17.7 04/07/2005 06:20:00 11.8 1 14.5 8.8 11.7 1 14.1 9.1 0.4 0 0.4 0.4 6 5 7 305 4 0 4 0 -17.4 0 -17.3 -17.5 04/07/2005 06:30:00 12 1.1 14.1 8.8 11.9 1.1 14.5 9.1 0.4 0 0.4 0.4 5 5 5 305 4 0 4 0 -17.5 0 -17.3 -17.5 04/07/2005 06:40:00 12.1 1.1 14.5 9.1 11.8 1 14.5 9.1 0.4 0 0.4 0.4 5 5 0 305 4 0 4 0 -17.5 0 -17.3 -17.5 04/07/2005 06:50:00 12.3 1 14.9 9.5 12.3 1 14.9 9.1 0.4 0 0.4 0.4 5 5 2 305 4 0 4 0 -17.5 0 -16.9 -17.7 04/07/2005 07:00:00 11.5 1.2 14.1 8.4 11.4 1.2 13.7 8.8 0.4 0 0.4 0.4 8 5 7 305 4 0 4 0 -17.4 0 -17.1 -17.5 04/07/2005 07:10:00 12.1 1.5 15.3 8 12 1.6 15.3 8 0.4 0 0.4 0.4 10 5 11 305 4 0 4 0 -17.3 0 -16.9 -17.5 04/07/2005 07:20:00 12.7 1 15.3 9.9 12.6 1 14.9 9.9 0.4 0 0.4 0.4 10 4 12 305 4 0 4 0 -17.2 0 -16.9 -17.3 04/07/2005 07:30:00 12.7 1 14.9 9.5 12.6 1 14.9 9.5 0.4 0 0.4 0.4 8 5 4 305 4 0 4 0 -17.2 0 -16.9 -17.3 04/07/2005 07:40:00 12.7 1 15.6 9.5 12.7 1 15.6 9.9 0.4 0 0.4 0.4 9 4 10 305 4 0 4 0 -17.1 0 -16.9 -17.3 04/07/2005 07:50:00 13.2 0.9 14.9 10.7 13.1 1 15.3 10.7 0.4 0 0.4 0.4 7 4 11 305 4 0 4 0 -17.1 0 -16.9 -17.1 04/07/2005 08:00:00 12.5 0.8 14.5 10.3 12.3 1 14.5 9.9 0.4 0 0.4 0.4 7 4 4 305 4 0 4 0 -16.9 0 -16.9 -17.1 04/07/2005 08:10:00 12 1 14.5 9.5 12 1.1 14.9 9.1 0.4 0 0.4 0.4 13 6 12 305 4 0 4 0 -16.9 0 -16.6 -16.9 04/07/2005 08:20:00 12.4 1.2 14.5 8.8 12.3 1.2 14.5 9.1 0.4 0 0.4 0.4 12 4 9 305 4 0 4 0 -16.9 0 -16.6 -16.9 04/07/2005 08:30:00 11.3 1 13.7 8.4 11.1 1 13.3 8.4 0.4 0 0.4 0.4 12 5 16 305 4 0 4 0 -16.8 0.1 -16.4 -16.9 04/07/2005 08:40:00 11.8 1 13.7 8.8 11.7 1 14.1 8.8 0.4 0 0.4 0.4 11 4 12 305 4 0 4 0 -16.9 0 -16.6 -16.9 04/07/2005 08:50:00 12 1.1 14.5 9.5 12 1.1 14.9 8.8 0.4 0 0.4 0.4 8 5 6 305 4 0 4 0 -16.8 0 -16.6 -16.9 04/07/2005 09:00:00 12.4 1.1 14.9 9.5 12.3 1 14.9 9.5 0.4 0 0.4 0.4 7 5 8 305 4 0 4 0 -16.8 0.1 -16.6 -16.9 04/07/2005 09:10:00 11.7 1.3 14.9 8 11.6 1.4 15.3 8.4 0.4 0 0.4 0.4 9 5 2 305 4 0 4 0 -16.8 0.1 -16.6 -16.9 04/07/2005 09:20:00 12.2 0.9 14.5 9.5 12.1 1 14.5 9.5 0.4 0 0.4 0.4 7 5 1 305 4 0 4 0 -16.7 0.1 -16.4 -16.9 04/07/2005 09:30:00 11.2 1.1 14.1 8.8 11.2 1.1 14.1 8.4 0.4 0 0.4 0.4 10 5 11 305 4 0 4 0 -16.7 0.1 -16.4 -16.9 04/07/2005 09:40:00 10.7 0.9 13 8 10.6 0.9 12.6 8 0.4 0 0.4 0.4 17 5 15 305 4 0 4 0 -16.4 0.1 -16 -16.6 04/07/2005 09:50:00 10.7 1.1 13.7 8.4 10.6 1.2 13.3 8 0.4 0 0.4 0.4 13 6 6 305 5 0 5 0 -16.3 0 -16 -16.6 04/07/2005 10:00:00 10.5 1.3 13.3 7.6 10.3 1.3 13.3 7.6 0.4 0 0.4 0.4 15 6 12 305 5 0 5 0 -16.3 0 -16 -16.6 04/07/2005 10:10:00 10.6 0.9 12.6 8 10.5 1 12.6 7.2 0.4 0 0.4 0.4 24 5 33 305 5 0 5 0 -16.3 0 -16 -16.6 04/07/2005 10:20:00 10.6 1 13.3 8.4 10.5 1 13 8 0.4 0 0.4 0.4 25 5 21 305 5 0 5 0 -16.2 0.1 -16 -16.4 04/07/2005 10:30:00 11.8 1 14.1 8.8 11.7 1.1 14.1 8 0.4 0 0.4 0.4 26 4 25 305 5 0 5 0 -16.1 0 -15.8 -16.2 04/07/2005 10:40:00 11.7 0.8 13.7 9.5 11.6 0.8 13.7 9.5 0.4 0 0.4 0.4 25 4 32 305 5 0 5 0 -16 0 -15.8 -16.2 04/07/2005 10:50:00 12.4 1.1 14.5 9.1 12.3 1.1 14.5 9.1 0.4 0 0.4 0.4 23 4 30 305 5 0 5 0 -16.1 0 -15.8 -16.2 04/07/2005 11:00:00 13.1 1 15.3 10.7 12.9 1.1 15.3 10.3 0.4 0 0.4 0.4 21 5 21 305 5 0 5 0 -15.9 0 -15.6 -16.2 04/07/2005 11:10:00 14.1 1.3 17.2 11.1 13.9 1.4 16.8 10.3 0.4 0 0.4 0.4 22 5 23 305 5 0 5 0 -15.8 0 -15.6 -16 04/07/2005 11:20:00 13.5 1.3 16.1 9.5 13.4 1.5 16.4 9.5 0.4 0 0.4 0.4 21 4 16 305 5 0 5 0 -15.8 0 -15.6 -16 04/07/2005 11:30:00 12.9 1 15.3 9.9 12.9 1 15.3 9.9 0.4 0 0.4 0.4 21 5 17 305 5 0 5 0 -15.7 0.1 -15.4 -15.8 04/07/2005 11:40:00 12.5 0.9 14.5 9.9 12.3 1 14.5 9.5 0.4 0 0.4 0.4 22 5 22 305 6 0 6 0 -15.5 0 -15.2 -15.6 04/07/2005 11:50:00 12.2 0.7 13.7 9.1 12.1 0.8 13.7 9.5 0.4 0 0.4 0.4 27 4 27 305 6 0 6 0 -15.5 0 -15 -15.6 04/07/2005 12:00:00 11.5 0.8 13.3 9.1 11.5 1 13.7 8.4 0.4 0 0.4 0.4 25 4 26 305 6 0 6 0 -15.3 0 -14.8 -15.6 04/07/2005 12:10:00 12.5 1 14.5 9.1 12.4 1.2 15.3 9.5 0.4 0 0.4 0.4 25 4 26 305 6 0 6 0 -15.2 0.1 -14.6 -15.4 04/07/2005 12:20:00 12.3 1.1 14.9 9.1 12.2 1.1 14.9 9.5 0.4 0 0.4 0.4 27 4 29 305 6 0 6 0 -15.2 0 -14.8 -15.4 04/07/2005 12:30:00 13.2 1.2 16.1 10.3 13 1.2 15.6 9.9 0.4 0 0.4 0.4 22 6 18 305 6 0 6 0 -15.2 0.1 -14.6 -15.2 04/07/2005 12:40:00 14.1 1 16.1 11.1 14.1 1 16.4 11.1 0.4 0 0.4 0.4 21 3 19 305 6 0 6 0 -15.2 0.1 -14.6 -15.2 04/07/2005 12:50:00 12.4 1.1 16.1 9.9 12.3 1.2 16.1 9.5 0.4 0 0.4 0.4 25 6 21 305 6 0 6 0 -15.1 0 -14.8 -15.2 04/07/2005 13:00:00 11.7 1 13.3 8.8 11.8 1 13.7 8.8 0.4 0 0.4 0.4 30 4 26 305 6 0 6 0 -15.2 0 -14.8 -15.4 04/07/2005 13:10:00 11 1.1 14.5 8.4 10.9 1.1 14.1 8.4 0.4 0 0.4 0.4 27 5 28 305 6 0 7 0 -15.2 0.1 -14.8 -15.4 04/07/2005 13:20:00 13 1.1 15.3 10.3 12.9 1.3 15.6 9.5 0.4 0 0.4 0.4 28 5 31 305 7 0 7 0 -15.1 0.1 -14.6 -15.2 04/07/2005 13:30:00 12.5 1 14.5 9.5 12.3 1.1 14.9 8.8 0.4 0 0.4 0.4 29 5 30 305 7 0 7 0 -15.2 0 -14.8 -15.4 04/07/2005 13:40:00 11.9 1 13.7 9.1 11.9 1.1 14.1 8.4 0.4 0 0.4 0.4 28 5 32 305 6 0 6 0 -15.3 0 -14.8 -15.4 04/07/2005 13:50:00 12.5 1 14.5 9.5 12.3 1 14.5 9.5 0.4 0 0.4 0.4 30 5 27 305 6 0 6 0 -15.2 0 -14.6 -15.2 04/07/2005 14:00:00 11.9 1 14.1 8.8 11.8 1.1 14.5 8.4 0.4 0 0.4 0.4 29 5 31 305 6 0 6 0 -15.1 0 -14.8 -15.2 04/07/2005 14:10:00 11.4 1.1 13.7 8.8 11.3 1.2 13.7 8 0.4 0 0.4 0.4 30 5 30 305 7 0 6 0 -15 0 -14.8 -15 04/07/2005 14:20:00 12.4 1.2 14.9 8.8 12.3 1.3 15.6 8.4 0.4 0 0.4 0.4 29 5 30 305 7 0 7 0 -14.9 0 -14.6 -15 04/07/2005 14:30:00 11.9 1.2 14.5 9.1 11.8 1.3 14.9 8 0.4 0 0.4 0.4 29 5 30 305 7 0 7 0 -14.8 0 -14.4 -15 04/07/2005 14:40:00 11.7 1.1 14.1 9.1 11.7 1.1 14.1 9.1 0.4 0 0.4 0.4 30 5 38 305 7 0 7 0 -14.7 0 -14.4 -14.6 04/07/2005 14:50:00 12.7 1 15.3 8.8 12.5 1.1 14.9 8.8 0.4 0 0.4 0.4 27 5 27 305 7 0 7 0 -14.7 0 -14.4 -14.8 04/07/2005 15:00:00 12 1 14.1 8.8 11.9 1.1 14.1 8.8 0.4 0 0.4 0.4 26 5 27 305 7 0 7 0 -14.7 0 -14.4 -14.8 04/07/2005 15:10:00 11.3 1 13.3 8.4 11.2 1 13.3 8.8 0.4 0 0.4 0.4 24 5 18 305 7 0 7 0 -14.7 0 -14.4 -14.8 04/07/2005 15:20:00 11.6 1 14.1 9.1 11.6 1.1 14.5 9.1 0.4 0 0.4 0.4 28 5 29 305 7 0 7 0 -14.6 0 -14.4 -14.6 04/07/2005 15:30:00 11.9 1.2 14.5 8.8 11.7 1.3 14.5 8.8 0.4 0 0.4 0.4 28 5 36 305 8 0 8 0 -14.5 0.1 -14.3 -14.6 04/07/2005 15:40:00 12.5 1 14.9 9.9 12.4 1.1 14.9 9.5 0.4 0 0.4 0.4 31 5 32 305 8 0 8 0 -14.5 0 -14.3 -14.6 04/07/2005 15:50:00 12.4 1.1 14.9 8.8 12.3 1.2 15.3 8.8 0.4 0 0.4 0.4 31 5 29 305 8 0 8 0 -14.5 0 -14.3 -14.6 04/07/2005 16:00:00 11.5 1 13.7 9.1 11.5 1 14.1 9.1 0.4 0 0.4 0.4 33 5 38 305 8 0 8 0 -14.4 0 -14.3 -14.6 04/07/2005 16:10:00 12.6 0.8 14.5 9.9 12.6 1 14.5 9.9 0.4 0 0.4 0.4 37 5 32 305 8 0 8 0 -14.6 0.1 -14.3 -14.6 04/07/2005 16:20:00 12.9 1 15.6 10.3 12.9 1.1 16.1 10.3 0.4 0 0.4 0.4 35 4 33 305 8 0 8 0 -14.5 0.1 -14.3 -14.6 04/07/2005 16:30:00 11.8 1.2 14.9 9.1 11.8 1.3 14.5 8.8 0.4 0 0.4 0.4 35 5 37 305 8 0 8 0 -14.4 0 -14.1 -14.6 04/07/2005 16:40:00 12.5 1.1 14.5 9.9 12.4 1.2 16.1 9.5 0.4 0 0.4 0.4 32 5 33 305 8 0 8 0 -14.4 0 -14.1 -14.4 04/07/2005 16:50:00 12 1.1 14.9 9.1 11.9 1.2 14.9 9.1 0.4 0 0.4 0.4 34 5 37 305 8 0 8 0 -14.4 0.1 -13.9 -14.6 04/07/2005 17:00:00 12 1.1 14.9 9.5 12 1.1 14.5 9.1 0.4 0 0.4 0.4 33 5 26 305 8 0 8 0 -14.4 0 -14.3 -14.6 04/07/2005 17:10:00 13.2 1.2 16.1 9.9 13.1 1.2 16.1 9.9 0.4 0 0.4 0.4 31 5 30 305 8 0 7 0 -14.6 0.1 -14.3 -14.6 04/07/2005 17:20:00 13.7 1.3 17.6 11.1 13.6 1.3 16.8 9.9 0.4 0 0.4 0.4 32 5 27 305 7 0 7 0 -14.5 0.1 -14.3 -14.6 04/07/2005 17:30:00 13.1 1.3 16.8 10.3 12.8 1.5 16.8 9.1 0.4 0 0.4 0.4 30 5 32 305 7 0 7 0 -14.4 0.1 -14.1 -14.6 04/07/2005 17:40:00 13.8 1.1 16.8 10.3 13.6 1.2 16.1 10.3 0.4 0 0.4 0.4 32 5 43 305 7 0 7 0 -14.4 0 -14.1 -14.6 04/07/2005 17:50:00 13.2 1.3 16.4 9.5 13.2 1.3 17.6 9.5 0.4 0 0.4 0.4 35 4 36 305 7 0 7 0 -14.4 0 -14.1 -14.6 04/07/2005 18:00:00 12.8 1.1 16.1 10.3 12.7 1.2 16.1 10.3 0.4 0 0.4 0.4 34 5 28 305 7 0 7 0 -14.2 0 -14.1 -14.4 04/07/2005 18:10:00 13.2 1 15.3 10.3 13.1 1.1 15.6 10.3 0.4 0 0.4 0.4 33 4 36 305 7 0 7 0 -14.2 0 -13.9 -14.3 04/07/2005 18:20:00 13.2 1.1 16.1 10.7 13.1 1.1 16.1 10.7 0.4 0 0.4 0.4 29 5 27 305 7 0 7 0 -14.2 0 -13.9 -14.3 04/07/2005 18:30:00 12.6 1 14.9 9.5 12.6 1.2 14.9 9.5 0.4 0 0.4 0.4 30 5 31 305 7 0 7 0 -14.2 0 -13.9 -14.3 04/07/2005 18:40:00 13 1.1 16.4 10.7 13 1.2 16.4 9.5 0.4 0 0.4 0.4 30 5 31 305 7 0 7 0 -14.2 0 -14.1 -14.3 04/07/2005 18:50:00 13.3 1.2 16.4 10.3 13.2 1.3 16.4 9.5 0.4 0 0.4 0.4 31 5 33 305 7 0 7 0 -14.2 0 -14.1 -14.3 04/07/2005 19:00:00 13.1 1 16.1 10.7 13 1.3 16.1 9.9 0.4 0 0.4 0.4 31 5 37 305 7 0 7 0 -14.2 0 -13.9 -14.3 04/07/2005 19:10:00 13 1.2 16.1 10.3 12.8 1.3 16.4 9.5 0.4 0 0.4 0.4 28 5 27 305 7 0 7 0 -14.2 0 -13.9 -14.3 04/07/2005 19:20:00 14.2 1.1 17.2 11.5 14.1 1.1 16.8 11.1 0.4 0 0.4 0.4 30 4 30 305 7 0 7 0 -14.2 0 -14.1 -14.3 04/07/2005 19:30:00 12.3 1.6 16.1 8.4 12 1.6 16.4 8.4 0.4 0 0.4 0.4 27 5 27 305 7 0 7 0 -14.1 0 -13.9 -14.3 04/07/2005 19:40:00 13.4 1.1 16.1 10.7 13.3 1.1 15.6 10.3 0.4 0 0.4 0.4 31 4 35 305 7 0 7 0 -14.2 0 -14.1 -14.3 04/07/2005 19:50:00 13.3 1.2 16.8 10.3 13 1.1 15.6 10.3 0.4 0 0.4 0.4 27 5 26 305 7 0 7 0 -14.1 0 -13.9 -14.3 04/07/2005 20:00:00 13.1 1.3 16.4 9.9 12.8 1.4 16.1 9.5 0.4 0 0.4 0.4 28 5 30 305 7 0 7 0 -14.1 0 -13.7 -14.3 04/07/2005 20:10:00 12.3 1.2 15.3 9.5 12.1 1.2 16.1 9.5 0.4 0 0.4 0.4 29 5 35 305 7 0 7 0 -14.1 0.1 -13.7 -14.3 04/07/2005 20:20:00 13 1 15.3 10.7 12.9 1 15.3 9.9 0.4 0 0.4 0.4 29 5 26 305 7 0 7 0 -14.1 0 -13.7 -14.3 04/07/2005 20:30:00 12.5 1.2 16.1 9.5 12.4 1.3 16.4 9.5 0.4 0 0.4 0.4 31 5 39 305 7 0 7 0 -14.1 0 -13.9 -14.3 04/07/2005 20:40:00 12.3 1 14.9 9.1 12.3 1.1 14.9 9.5 0.4 0 0.4 0.4 33 5 40 305 7 0 7 0 -14.1 0.1 -13.7 -14.3 04/07/2005 20:50:00 12.2 1 15.3 9.5 12.1 1 14.9 9.5 0.4 0 0.4 0.4 30 5 36 305 7 0 7 0 -14.1 0 -13.7 -14.3 04/07/2005 21:00:00 13.1 1 15.3 10.7 13 1 15.6 10.7 0.4 0 0.4 0.4 31 4 35 305 7 0 7 0 -14 0.1 -13.7 -14.3 04/07/2005 21:10:00 12.1 1.1 15.3 9.5 11.9 1.2 15.3 8.4 0.4 0 0.4 0.4 32 5 32 305 7 0 7 0 -14 0.1 -13.7 -14.3 04/07/2005 21:20:00 12.7 1.1 15.6 9.5 12.6 1.1 16.4 9.1 0.4 0 0.4 0.4 32 5 32 305 7 0 7 0 -13.9 0 -13.7 -14.1 04/07/2005 21:30:00 12.8 0.9 15.3 10.7 12.7 1 15.6 9.9 0.4 0 0.4 0.4 31 5 31 305 7 0 7 0 -13.9 0 -13.7 -14.1 04/07/2005 21:40:00 11.9 1 14.5 9.5 11.8 1.1 14.9 9.1 0.4 0 0.4 0.4 32 5 36 305 7 0 7 0 -13.8 0 -13.7 -14.1 04/07/2005 21:50:00 12.2 1.1 14.9 9.5 12.1 1.2 14.9 9.5 0.4 0 0.4 0.4 31 4 31 305 7 0 7 0 -13.7 0 -13.5 -13.9 04/07/2005 22:00:00 13.1 1 15.6 11.1 13.1 1.2 16.1 10.7 0.4 0 0.4 0.4 33 5 37 305 8 0 8 0 -13.7 0 -13.3 -13.9 04/07/2005 22:10:00 13.2 1.2 16.1 9.5 13.1 1.3 16.1 9.9 0.4 0 0.4 0.4 33 4 37 305 8 0 8 0 -13.7 0 -13.3 -13.7 04/07/2005 22:20:00 12.5 1 14.9 10.3 12.5 1.1 15.3 9.5 0.4 0 0.4 0.4 33 4 29 305 8 0 8 0 -13.6 0 -13.3 -13.7 04/07/2005 22:30:00 13 1 15.6 10.7 13 1 16.4 10.7 0.4 0 0.4 0.4 33 5 34 305 8 0 8 0 -13.6 0 -13.3 -13.7 04/07/2005 22:40:00 13.1 1 16.8 10.7 13.1 1 15.6 10.7 0.4 0 0.4 0.4 34 5 30 305 8 0 8 0 -13.6 0 -13.3 -13.7 04/07/2005 22:50:00 12.5 0.8 14.9 9.9 12.5 0.9 14.9 9.9 0.4 0 0.4 0.4 33 5 42 305 8 0 8 0 -13.6 0 -13.3 -13.7 04/07/2005 23:00:00 13.5 1.1 16.1 10.7 13.5 1.2 15.6 10.3 0.4 0 0.4 0.4 36 4 33 305 8 0 8 0 -13.5 0.1 -13.3 -13.7 04/07/2005 23:10:00 14.2 1.5 17.6 9.9 14.3 1.5 17.9 9.9 0.4 0 0.4 0.4 37 5 32 305 8 0 8 0 -13.4 0 -13.1 -13.7 04/07/2005 23:20:00 14.7 1.1 17.2 11.8 14.8 1.2 17.9 11.5 0.4 0 0.4 0.4 36 4 33 305 8 0 8 0 -13.4 0 -13.3 -13.5 04/07/2005 23:30:00 14.8 1 17.6 11.8 14.8 1.1 17.6 11.5 0.4 0 0.4 0.4 37 4 37 305 8 0 8 0 -13.4 0 -13.3 -13.5 04/07/2005 23:40:00 14.5 1.1 17.2 12.2 14.4 1.1 17.2 11.8 0.4 0 0.4 0.4 38 5 39 305 8 0 8 0 -13.3 0 -13.3 -13.5 04/07/2005 23:50:00 14.3 1 16.8 11.8 14.2 1 17.2 11.1 0.4 0 0.4 0.4 37 5 33 305 8 0 8 0 -13.3 0 -13.1 -13.5 04/08/2005 00:00:00 13.5 1.2 16.4 11.1 13.5 1.3 16.8 10.3 0.4 0 0.4 0.4 39 5 39 305 8 0 8 0 -13.2 0 -12.9 -13.3 04/08/2005 00:10:00 14 1.1 17.2 11.1 14 1.3 17.6 11.1 0.4 0 0.4 0.4 36 4 39 305 8 0 8 0 -13.1 0 -12.9 -13.3 04/08/2005 00:20:00 14 1.1 16.8 11.5 14 1.1 17.6 11.1 0.4 0 0.4 0.4 36 5 32 305 8 0 8 0 -13.1 0 -12.7 -13.3 04/08/2005 00:30:00 13.1 0.9 14.9 10.7 13.1 1 15.3 10.7 0.4 0 0.4 0.4 35 4 31 305 8 0 8 0 -13 0 -12.7 -13.3 04/08/2005 00:40:00 13.5 1.1 16.1 10.3 13.5 1 16.1 11.1 0.4 0 0.4 0.4 37 5 38 305 8 0 8 0 -13 0 -12.7 -13.1 04/08/2005 00:50:00 13.1 1 15.3 10.3 13 1.1 15.3 10.3 0.4 0 0.4 0.4 37 5 42 305 8 0 8 0 -13 0 -12.9 -13.3 04/08/2005 01:00:00 14.2 1.1 17.2 11.5 14.1 1.3 17.2 10.7 0.4 0 0.4 0.4 36 5 33 305 8 0 8 0 -13.1 0 -12.9 -13.3 04/08/2005 01:10:00 14.3 1.2 16.8 11.5 14.1 1.3 17.2 10.3 0.4 0 0.4 0.4 34 5 43 305 8 0 8 0 -13.1 0 -12.7 -13.3 04/08/2005 01:20:00 14.1 1 16.8 11.5 14 1.2 16.8 10.3 0.4 0 0.4 0.4 36 5 35 305 8 0 8 0 -13 0.1 -12.7 -13.1 04/08/2005 01:30:00 13.7 1.4 17.2 10.7 13.6 1.5 17.6 10.3 0.4 0 0.4 0.4 36 5 35 305 8 0 8 0 -13 0 -12.7 -13.1 04/08/2005 01:40:00 14.6 1.1 17.2 11.8 14.5 1.2 17.2 11.1 0.4 0 0.4 0.4 37 5 32 305 8 0 8 0 -13 0 -12.9 -13.1 04/08/2005 01:50:00 13.8 1.2 16.4 10.7 13.8 1.3 16.8 10.3 0.4 0 0.4 0.4 39 5 39 305 8 0 9 0 -12.9 0 -12.9 -12.9 04/08/2005 02:00:00 14.1 1.1 16.8 11.8 14.2 1.1 17.2 11.8 0.4 0 0.4 0.4 39 5 32 305 9 0 8 0 -12.9 0 -12.9 -12.9 04/08/2005 02:10:00 13.3 1 16.1 11.1 13.4 1.1 16.8 11.1 0.4 0 0.4 0.4 39 5 41 305 9 0 8 0 -12.9 0 -12.7 -12.9 04/08/2005 02:20:00 13.9 1 16.1 11.5 13.9 1.1 16.8 11.1 0.4 0 0.4 0.4 36 5 42 305 9 0 9 0 -12.9 0 -12.7 -12.9 04/08/2005 02:30:00 14.3 1.2 17.2 11.5 14.2 1.2 17.2 11.1 0.4 0 0.4 0.4 35 4 31 305 9 0 9 0 -12.9 0 -12.7 -13.1 04/08/2005 02:40:00 14.3 1.2 17.6 11.1 14.2 1.3 17.6 10.7 0.4 0 0.4 0.4 35 5 33 305 9 0 9 0 -12.9 0 -12.9 -13.1 04/08/2005 02:50:00 14 1.3 17.2 11.1 14 1.4 17.6 10.7 0.4 0 0.4 0.4 35 5 26 305 9 0 9 0 -12.9 0 -12.5 -13.1 04/08/2005 03:00:00 15.2 1.2 18.3 11.1 15.1 1.2 18.3 11.8 0.4 0 0.4 0.4 38 5 34 305 9 0 9 0 -12.9 0.1 -12.5 -13.1 04/08/2005 03:10:00 15.9 1.3 18.7 12.6 15.7 1.2 18.7 12.6 0.4 0 0.4 0.4 36 4 37 305 9 0 9 0 -13 0.1 -12.5 -13.1 04/08/2005 03:20:00 15.2 1.3 18.7 12.2 15 1.4 19.1 11.8 0.4 0 0.4 0.4 37 5 30 305 9 0 9 0 -12.9 0.1 -12.5 -13.1 04/08/2005 03:30:00 16 1.4 19.9 12.2 15.7 1.5 19.1 11.8 0.4 0 0.4 0.4 35 5 36 305 9 0 9 0 -12.9 0.1 -12.5 -12.9 04/08/2005 03:40:00 15.2 1.3 18.3 11.1 15.2 1.4 18.7 11.1 0.4 0 0.4 0.4 39 5 42 305 9 0 9 0 -12.9 0 -12.5 -13.1 04/08/2005 03:50:00 15.6 1.1 18.3 12.6 15.4 1.1 18.3 12.6 0.4 0 0.4 0.4 36 4 35 305 9 0 9 0 -12.8 0.1 -12.5 -13.1 04/08/2005 04:00:00 14.9 1.5 18.3 9.9 14.9 1.5 18.3 9.9 0.4 0 0.4 0.4 37 5 33 305 9 0 9 0 -12.8 0 -12.5 -12.9 04/08/2005 04:10:00 14 1.3 17.6 10.3 13.8 1.3 17.6 10.3 0.4 0 0.4 0.4 34 6 32 305 9 0 9 0 -12.7 0 -12.5 -12.9 04/08/2005 04:20:00 13.9 1.6 18.7 10.7 14 1.6 18.3 10.7 0.4 0 0.4 0.4 38 5 36 305 9 0 9 0 -12.7 0 -12.5 -12.9 04/08/2005 04:30:00 12.9 1.3 16.4 9.5 12.7 1.2 15.6 9.5 0.4 0 0.4 0.4 34 5 27 305 9 0 9 0 -12.6 0 -12.3 -12.9 04/08/2005 04:40:00 12.8 1.1 16.1 10.3 12.7 1.2 15.3 9.9 0.4 0 0.4 0.4 33 5 32 305 9 0 9 0 -12.7 0 -12.5 -12.9 04/08/2005 04:50:00 13.9 1.2 17.2 10.3 13.9 1.3 17.6 9.9 0.4 0 0.4 0.4 38 6 34 305 9 0 9 0 -12.7 0 -12.3 -12.9 04/08/2005 05:00:00 15.7 1.7 19.9 10.7 15.6 1.6 19.1 11.8 0.4 0 0.4 0.4 36 5 34 305 9 0 9 0 -12.7 0.1 -12.5 -12.9 04/08/2005 05:10:00 15.9 1.5 19.1 11.8 15.7 1.5 19.9 11.8 0.4 0 0.4 0.4 35 5 40 305 9 0 9 0 -12.8 0 -12.5 -12.9 04/08/2005 05:20:00 15 1.5 19.5 11.5 14.8 1.7 19.5 10.7 0.4 0 0.4 0.4 37 5 31 305 9 0 9 0 -12.7 0 -12.5 -12.9 04/08/2005 05:30:00 13 1.1 15.6 9.9 13.1 1.2 15.3 9.9 0.4 0 0.4 0.4 38 5 30 305 9 0 9 0 -12.7 0 -12.5 -12.9 04/08/2005 05:40:00 13.7 1.3 18.3 11.5 13.6 1.3 18.7 10.7 0.4 0 0.4 0.4 38 5 33 305 9 0 9 0 -12.8 0.1 -12.5 -12.9 04/08/2005 05:50:00 14.6 1 16.8 11.8 14.6 1 16.8 11.5 0.4 0 0.4 0.4 42 4 43 305 9 0 9 0 -12.9 0.1 -12.5 -13.1 04/08/2005 06:00:00 14.3 1.2 17.9 11.5 14.4 1.2 17.2 11.1 0.4 0 0.4 0.4 39 5 36 305 9 0 9 0 -12.9 0.1 -12.5 -13.1 04/08/2005 06:10:00 14.1 1.1 16.4 11.5 14 1.2 16.4 10.3 0.4 0 0.4 0.4 41 5 42 305 9 0 9 0 -13 0 -12.7 -13.1 04/08/2005 06:20:00 12.8 1 15.3 10.3 12.9 1 15.3 9.9 0.4 0 0.4 0.4 39 4 39 305 9 0 9 0 -12.9 0.1 -12.5 -13.1 04/08/2005 06:30:00 12.5 1.6 16.1 9.1 12.3 1.5 16.4 9.5 0.4 0 0.4 0.4 33 5 24 305 9 0 9 0 -12.9 0 -12.5 -12.9 04/08/2005 06:40:00 14.1 1.3 17.2 10.7 13.8 1.3 17.2 10.7 0.4 0 0.4 0.4 31 5 30 305 9 0 9 0 -12.9 0.1 -12.5 -13.1 04/08/2005 06:50:00 14.5 1.3 17.6 11.1 14.4 1.4 17.9 10.7 0.4 0 0.4 0.4 39 5 39 305 9 0 9 0 -12.9 0.1 -12.5 -13.1 04/08/2005 07:00:00 12.5 1 15.6 9.5 12.3 1 14.9 9.1 0.4 0 0.4 0.4 39 5 36 305 9 0 9 0 -12.9 0 -12.5 -12.9 04/08/2005 07:10:00 13.9 1.8 17.9 9.9 13.8 1.8 18.3 10.3 0.4 0 0.4 0.4 38 6 38 305 9 0 9 0 -12.9 0.1 -12.5 -12.9 04/08/2005 07:20:00 15.7 1.3 19.9 12.6 15.6 1.3 19.1 11.8 0.4 0 0.4 0.4 37 5 37 305 9 0 9 0 -13 0.1 -12.5 -13.1 04/08/2005 07:30:00 14.3 1.3 18.7 11.5 14.2 1.3 17.9 11.5 0.4 0 0.4 0.4 38 5 32 305 9 0 9 0 -12.9 0.1 -12.5 -13.1 04/08/2005 07:40:00 14.2 1.2 17.2 10.3 14.2 1.3 17.2 10.3 0.4 0 0.4 0.4 38 5 32 305 9 0 9 0 -12.8 0 -12.5 -12.9 04/08/2005 07:50:00 14.5 1.3 17.6 10.7 14.5 1.3 17.9 10.7 0.4 0 0.4 0.4 38 5 33 305 9 0 9 0 -12.9 0.1 -12.5 -12.9 04/08/2005 08:00:00 14.8 1.2 17.6 11.8 14.7 1.3 17.9 11.1 0.4 0 0.4 0.4 40 5 41 305 9 0 9 0 -12.9 0 -12.9 -13.1 04/08/2005 08:10:00 14 1 16.4 11.5 13.8 1.1 16.4 11.5 0.4 0 0.4 0.4 38 4 33 305 9 0 9 0 -12.8 0 -12.7 -12.9 04/08/2005 08:20:00 14.2 1.2 17.2 11.5 14.3 1.3 17.6 10.7 0.4 0 0.4 0.4 39 4 42 305 10 0 9 0 -12.8 0 -12.5 -12.9 04/08/2005 08:30:00 14.5 1.5 17.9 11.1 14.6 1.5 18.3 11.1 0.4 0 0.4 0.4 39 5 37 305 10 0 10 0 -12.9 0.1 -12.5 -13.1 04/08/2005 08:40:00 14.6 1.1 17.2 11.8 14.6 1.1 17.2 11.5 0.4 0 0.4 0.4 40 4 35 305 10 0 10 0 -13 0.1 -12.5 -13.1 04/08/2005 08:50:00 13.9 1.3 17.2 10.7 13.9 1.4 17.2 10.7 0.4 0 0.4 0.4 38 4 43 305 10 0 10 0 -12.9 0.1 -12.5 -13.1 04/08/2005 09:00:00 14.4 1 16.8 11.5 14.4 1.1 17.2 11.8 0.4 0 0.4 0.4 40 5 39 305 10 0 9 0 -12.9 0.1 -12.5 -12.9 04/08/2005 09:10:00 13.4 1 16.4 11.1 13.3 1.2 16.1 10.3 0.4 0 0.4 0.4 38 5 28 305 10 0 10 0 -12.8 0 -12.5 -12.9 04/08/2005 09:20:00 14.2 1.1 17.2 11.5 14.1 1.1 16.8 11.5 0.4 0 0.4 0.4 37 4 28 305 10 0 10 0 -12.8 0.1 -12.5 -13.1 04/08/2005 09:30:00 13.9 1.3 16.4 10.7 13.7 1.3 16.8 10.7 0.4 0 0.4 0.4 37 4 33 305 10 0 10 0 -12.9 0.1 -12.5 -13.1 04/08/2005 09:40:00 13.1 1 16.1 10.3 12.9 1.1 16.1 10.3 0.4 0 0.4 0.4 34 5 37 305 10 0 10 0 -12.9 0.1 -12.5 -13.1 04/08/2005 09:50:00 15.2 1.5 18.7 11.5 15.1 1.6 18.3 11.5 0.4 0 0.4 0.4 36 5 28 305 10 0 10 0 -13 0.1 -12.5 -13.3 04/08/2005 10:00:00 13.9 1.3 17.2 11.1 13.9 1.4 17.6 11.1 0.4 0 0.4 0.4 37 5 35 305 10 0 10 0 -13 0.1 -12.7 -13.1 04/08/2005 10:10:00 14.6 1.1 17.2 11.8 14.4 1.2 17.2 11.1 0.4 0 0.4 0.4 35 4 39 305 10 0 10 0 -13 0 -12.7 -13.3 04/08/2005 10:20:00 13.7 1.3 16.8 9.9 13.6 1.5 16.8 10.3 0.4 0 0.4 0.4 37 5 35 305 10 0 10 0 -13 0.1 -12.7 -13.1 04/08/2005 10:30:00 13.8 1.1 17.2 10.7 13.7 1.2 16.4 10.7 0.4 0 0.4 0.4 34 5 26 305 10 0 10 0 -13 0.1 -12.5 -13.1 04/08/2005 10:40:00 13.6 1.2 17.2 10.7 13.5 1.3 17.2 9.9 0.4 0 0.4 0.4 37 4 39 305 10 0 10 0 -13 0 -12.7 -13.1 04/08/2005 10:50:00 14 1.5 17.2 9.9 14 1.6 17.2 9.9 0.4 0 0.4 0.4 40 5 38 305 10 0 10 0 -13 0 -12.7 -13.1 04/08/2005 11:00:00 15.4 1.1 18.3 12.2 15.2 1.2 17.9 11.8 0.4 0 0.4 0.4 36 4 33 305 10 0 10 0 -13 0.1 -12.5 -13.1 04/08/2005 11:10:00 15.6 1.1 18.3 12.6 15.3 1.2 17.6 11.8 0.4 0 0.4 0.4 34 4 33 305 10 0 10 0 -13.1 0 -12.7 -13.3 04/08/2005 11:20:00 15.2 1 17.9 12.2 15.2 1.1 17.9 11.8 0.4 0 0.4 0.4 38 4 37 305 10 0 10 0 -13.1 0 -12.9 -13.3 04/08/2005 11:30:00 14.7 1 17.2 12.6 14.6 1.1 17.9 11.5 0.4 0 0.4 0.4 40 4 38 305 10 0 10 0 -13.1 0 -12.9 -13.3 04/08/2005 11:40:00 14 1 16.4 11.1 14 1.1 17.2 11.1 0.4 0 0.4 0.4 39 4 40 305 10 0 10 0 -13.2 0 -12.9 -13.3 04/08/2005 11:50:00 13.7 1.3 17.2 10.7 13.6 1.3 16.8 10.7 0.4 0 0.4 0.4 40 5 41 305 10 0 10 0 -13.3 0 -12.9 -13.3 04/08/2005 12:00:00 13.5 1.3 17.2 10.7 13.3 1.3 16.4 10.3 0.4 0 0.4 0.4 36 6 32 305 10 0 10 0 -13.2 0 -12.9 -13.3 04/08/2005 12:10:00 13.5 1 15.6 11.1 13.5 1 15.6 10.7 0.4 0 0.4 0.4 39 5 35 305 10 0 10 0 -13.2 0 -12.9 -13.3 04/08/2005 12:20:00 14.4 1.2 16.8 11.5 14.2 1.2 16.8 11.1 0.4 0 0.4 0.4 40 5 49 305 10 0 10 0 -13.3 0 -12.9 -13.3 04/08/2005 12:30:00 13.7 1.2 16.8 10.7 13.5 1.3 16.8 10.7 0.4 0 0.4 0.4 39 5 42 305 10 0 10 0 -13.3 0 -12.9 -13.5 04/08/2005 12:40:00 13.7 0.9 16.4 11.5 13.7 1 15.6 11.5 0.4 0 0.4 0.4 38 5 45 305 10 0 10 0 -13.2 0 -12.9 -13.3 04/08/2005 12:50:00 13.6 1.1 16.4 10.7 13.5 1.1 16.4 10.7 0.4 0 0.4 0.4 39 5 31 305 10 0 10 0 -13.1 0.1 -12.9 -13.3 04/08/2005 13:00:00 13.6 1 15.6 11.1 13.5 1.1 16.1 10.3 0.4 0 0.4 0.4 38 4 40 305 10 0 10 0 -13.1 0 -12.9 -13.3 04/08/2005 13:10:00 14.3 0.8 16.4 12.2 14.1 0.9 16.4 12.2 0.4 0 0.4 0.4 38 4 37 305 10 0 10 0 -13.2 0 -12.9 -13.3 04/08/2005 13:20:00 13 1.1 15.3 10.3 12.9 1.1 15.3 10.3 0.4 0 0.4 0.4 38 5 43 305 10 0 10 0 -13.1 0 -12.9 -13.3 04/08/2005 13:30:00 12.9 1.2 15.3 10.3 12.9 1.2 15.3 9.9 0.4 0 0.4 0.4 37 4 36 305 10 0 10 0 -13 0 -12.7 -13.3 04/08/2005 13:40:00 11.7 1 14.1 9.1 11.7 1 14.1 9.5 0.4 0 0.4 0.4 36 4 31 305 10 0 11 0 -12.9 0.1 -12.5 -13.1 04/08/2005 13:50:00 13 0.7 14.5 9.9 12.9 0.8 14.5 10.3 0.4 0 0.4 0.4 35 3 37 305 10 0 11 0 -13 0.1 -12.7 -13.3 04/08/2005 14:00:00 11.8 1.1 14.1 9.1 11.7 1.2 14.5 9.1 0.4 0 0.4 0.4 36 5 40 305 10 0 11 0 -12.9 0.1 -12.5 -13.1 04/08/2005 14:10:00 11.9 0.8 13.7 9.5 11.8 0.9 14.1 9.1 0.4 0 0.4 0.4 34 4 37 305 11 0 11 0 -13 0.1 -12.5 -13.1 04/08/2005 14:20:00 11.8 0.8 14.1 9.5 11.7 1 14.5 9.1 0.4 0 0.4 0.4 34 4 33 305 11 0 11 0 -12.9 0.1 -12.5 -13.1 04/08/2005 14:30:00 12.4 0.9 14.5 9.9 12.4 1 14.9 9.9 0.4 0 0.4 0.4 35 5 30 305 11 0 11 0 -12.9 0.1 -12.5 -13.1 04/08/2005 14:40:00 12.3 0.7 13.7 10.3 12.3 0.8 14.1 10.3 0.4 0 0.4 0.4 33 4 29 305 11 0 11 0 -12.8 0.1 -12.5 -12.9 04/08/2005 14:50:00 12.4 1 14.9 10.3 12.5 1 15.3 10.3 0.4 0 0.4 0.4 35 5 40 305 11 0 11 0 -12.8 0 -12.5 -12.9 04/08/2005 15:00:00 11.5 0.8 13 9.1 11.4 0.9 13.3 9.1 0.4 0 0.4 0.4 34 4 37 305 11 0 11 0 -12.8 0.1 -12.5 -13.1 04/08/2005 15:10:00 11.8 1 13.7 8.8 11.7 1 14.1 8.8 0.4 0 0.4 0.4 34 5 37 305 11 0 11 0 -12.8 0 -12.5 -12.9 04/08/2005 15:20:00 12.2 1.3 15.6 9.5 12.2 1.3 15.6 9.1 0.4 0 0.4 0.4 43 5 41 305 11 0 11 0 -12.8 0 -12.5 -12.9 04/08/2005 15:30:00 10.5 0.9 13 8.4 10.5 1 13.3 8.4 0.4 0 0.4 0.4 38 6 39 305 11 0 11 0 -12.6 0 -12.1 -12.9 04/08/2005 15:40:00 11.8 1.2 14.5 9.1 11.7 1.3 14.5 8 0.4 0 0.4 0.4 41 7 45 305 11 0 11 0 -12.6 0 -12.1 -12.9 04/08/2005 15:50:00 11.7 0.9 13.7 8.8 11.8 1 14.1 8.8 0.4 0 0.4 0.4 42 6 45 305 11 0 11 0 -12.6 0 -12.3 -12.9 04/08/2005 16:00:00 12 1.1 14.1 8.8 12.1 1.1 14.5 8.8 0.4 0 0.4 0.4 33 5 32 305 11 0 11 0 -12.6 0 -12.1 -12.9 04/08/2005 16:10:00 12.9 0.9 14.9 10.3 12.8 1.1 15.3 9.5 0.4 0 0.4 0.4 33 5 27 305 11 0 12 0 -12.7 0 -12.3 -12.9 04/08/2005 16:20:00 13.1 0.9 15.3 10.3 13.2 1 15.3 9.9 0.4 0 0.4 0.4 39 4 41 305 11 0 12 0 -12.7 0 -12.3 -12.9 04/08/2005 16:30:00 11.8 0.8 13.7 9.9 11.8 0.8 14.1 9.5 0.4 0 0.4 0.4 32 5 35 305 11 0 11 0 -12.7 0 -12.3 -12.9 04/08/2005 16:40:00 12 0.9 13.7 9.9 12 1 14.5 9.9 0.4 0 0.4 0.4 35 6 44 305 12 0 12 0 -12.8 0.1 -12.3 -12.9 04/08/2005 16:50:00 12.5 0.8 13.7 9.9 12.5 0.8 14.1 9.5 0.4 0 0.4 0.4 36 4 33 305 11 0 12 0 -12.8 0 -12.5 -12.9 04/08/2005 17:00:00 11.9 1 13.7 9.9 11.9 1.1 14.5 9.1 0.4 0 0.4 0.4 31 5 33 305 11 0 11 0 -12.8 0 -12.5 -12.9 04/08/2005 17:10:00 12.6 0.9 14.9 9.5 12.5 1 14.9 9.9 0.4 0 0.4 0.4 27 4 24 305 11 0 11 0 -13 0.1 -12.5 -13.1 04/08/2005 17:20:00 12.8 1 15.3 10.3 12.7 1.1 15.3 10.3 0.4 0 0.4 0.4 31 5 31 305 11 0 11 0 -13 0.1 -12.5 -13.3 04/08/2005 17:30:00 12.8 1 14.9 10.7 12.7 1 15.3 10.7 0.4 0 0.4 0.4 29 5 27 305 11 0 11 0 -13 0.1 -12.7 -13.1 04/08/2005 17:40:00 11.8 1.1 14.5 8 11.7 1.1 14.1 8.8 0.4 0 0.4 0.4 29 5 37 305 11 0 11 0 -13 0.1 -12.5 -13.3 04/08/2005 17:50:00 12.3 0.9 14.5 9.5 12.3 1 14.5 9.5 0.4 0 0.4 0.4 32 4 32 305 11 0 11 0 -13 0.1 -12.7 -13.3 04/08/2005 18:00:00 13.1 0.9 14.9 10.3 12.8 0.9 14.9 10.7 0.4 0 0.4 0.4 31 5 28 305 11 0 11 0 -13.1 0 -12.7 -13.3 04/08/2005 18:10:00 12.2 1.2 15.3 9.1 12 1.3 15.3 8.8 0.4 0 0.4 0.4 30 5 32 305 11 0 11 0 -13.1 0 -12.9 -13.3 04/08/2005 18:20:00 11.4 0.9 13.3 8.8 11.2 1 13.3 8.4 0.4 0 0.4 0.4 28 5 37 305 11 0 11 0 -13 0.1 -12.5 -13.1 04/08/2005 18:30:00 11.9 0.8 13.7 9.5 11.8 0.9 14.1 9.9 0.4 0 0.4 0.4 29 5 27 305 11 0 11 0 -12.9 0.1 -12.5 -13.1 04/08/2005 18:40:00 12.6 1.3 14.9 9.5 12.5 1.3 15.6 9.9 0.4 0 0.4 0.4 33 5 40 305 11 0 11 0 -12.9 0.1 -12.5 -13.1 04/08/2005 18:50:00 12.3 0.8 14.1 9.9 12.1 0.9 14.5 9.5 0.4 0 0.4 0.4 33 5 39 305 11 0 11 0 -12.7 0 -12.5 -12.9 04/08/2005 19:00:00 14 1.1 16.4 10.7 14 1.2 16.4 10.3 0.4 0 0.4 0.4 34 4 30 305 11 0 11 0 -12.8 0.1 -12.5 -12.9 04/08/2005 19:10:00 14.2 1 16.4 11.5 14.1 1 16.4 10.7 0.4 0 0.4 0.4 34 5 31 305 11 0 11 0 -12.8 0 -12.5 -12.9 04/08/2005 19:20:00 13.2 1 15.3 10.7 13.2 1.1 15.3 10.3 0.4 0 0.4 0.4 36 5 35 305 11 0 11 0 -12.7 0 -12.5 -12.9 04/08/2005 19:30:00 13.4 1 15.6 11.1 13.5 1.2 16.4 10.3 0.4 0 0.4 0.4 38 4 39 305 11 0 11 0 -12.8 0.1 -12.5 -13.1 04/08/2005 19:40:00 14.1 1.1 16.4 11.5 13.9 1.1 16.4 11.5 0.4 0 0.4 0.4 35 4 32 305 11 0 11 0 -12.9 0.1 -12.5 -13.1 04/08/2005 19:50:00 13.5 0.9 15.6 11.5 13.6 1 15.6 11.5 0.4 0 0.4 0.4 37 4 33 305 11 0 11 0 -12.9 0 -12.5 -13.1 04/08/2005 20:00:00 13.3 0.9 16.1 11.1 13.3 1 15.6 10.3 0.4 0 0.4 0.4 37 5 29 305 11 0 11 0 -12.9 0 -12.9 -13.1 04/08/2005 20:10:00 13.2 1 15.6 10.7 13.1 1 15.6 10.7 0.4 0 0.4 0.4 36 4 33 305 11 0 11 0 -13 0 -12.9 -13.1 04/08/2005 20:20:00 12.9 1 16.1 10.3 12.8 1.1 16.1 9.9 0.4 0 0.4 0.4 38 5 45 305 11 0 11 0 -13 0 -12.9 -13.1 04/08/2005 20:30:00 13.2 1.1 16.1 10.3 13.1 1 15.6 10.3 0.4 0 0.4 0.4 36 4 37 305 11 0 11 0 -13.1 0 -12.9 -13.3 04/08/2005 20:40:00 12.6 1 15.3 10.3 12.6 1 15.6 10.3 0.4 0 0.4 0.4 38 4 36 305 11 0 11 0 -13.1 0 -12.9 -13.3 04/08/2005 20:50:00 11.1 0.9 13.7 8.8 10.9 0.9 13.7 8.4 0.4 0 0.4 0.4 38 6 35 305 11 0 11 0 -13 0 -12.7 -13.1 04/08/2005 21:00:00 11.8 1 14.1 9.5 11.6 1.1 14.1 9.1 0.4 0 0.4 0.4 36 5 39 305 11 0 11 0 -13 0 -12.7 -13.3 04/08/2005 21:10:00 11.8 1 14.1 9.1 11.7 1 14.1 9.1 0.4 0 0.4 0.4 36 5 32 305 11 0 11 0 -13.1 0 -12.9 -13.3 04/08/2005 21:20:00 11.4 1.2 14.1 8.4 11.3 1.3 14.5 8.8 0.4 0 0.4 0.4 37 5 38 305 11 0 11 0 -13.2 0 -12.9 -13.3 04/08/2005 21:30:00 12.3 1.1 15.3 9.9 12.3 1.1 15.3 9.9 0.4 0 0.4 0.4 39 5 32 305 11 0 11 0 -13.3 0 -12.9 -13.5 04/08/2005 21:40:00 11.9 1 14.5 8.8 11.8 1.1 14.1 8.8 0.4 0 0.4 0.4 39 5 38 305 11 0 11 0 -13.2 0 -12.9 -13.3 04/08/2005 21:50:00 11.2 1 13.7 9.1 11.1 1.1 13.7 8.4 0.4 0 0.4 0.4 39 5 40 305 11 0 11 0 -13.3 0 -12.9 -13.5 04/08/2005 22:00:00 10.6 1 13 7.6 10.5 1 13 7.6 0.4 0 0.4 0.4 38 5 36 305 11 0 11 0 -13.2 0 -12.9 -13.3 04/08/2005 22:10:00 10.2 0.8 12.6 7.6 10.3 0.9 12.2 7.6 0.4 0 0.4 0.4 36 5 35 305 11 0 11 0 -13.3 0 -13.1 -13.5 04/08/2005 22:20:00 10.9 1 13 8.4 10.9 1 13.3 8.8 0.4 0 0.4 0.4 40 5 36 305 11 0 11 0 -13.3 0 -12.9 -13.3 04/08/2005 22:30:00 10.1 1.2 13 7.6 10.1 1.2 13.7 8 0.4 0 0.4 0.4 40 6 35 305 11 0 11 0 -13.3 0 -12.9 -13.5 04/08/2005 22:40:00 10.4 0.8 12.2 8 10.2 1 12.6 8 0.4 0 0.4 0.4 36 5 31 305 10 0 10 0 -13.4 0 -12.9 -13.5 04/08/2005 22:50:00 11 0.9 13.3 8.8 11 0.9 13.3 8.4 0.4 0 0.4 0.4 41 5 40 305 10 0 11 0 -13.3 0 -13.1 -13.5 04/08/2005 23:00:00 10.9 1.1 13 8 10.8 1.2 13.3 8 0.4 0 0.4 0.4 40 5 46 305 10 0 11 0 -13.3 0.1 -12.9 -13.5 04/08/2005 23:10:00 10.7 1 13 8 10.5 1 12.6 7.2 0.4 0 0.4 0.4 35 6 28 305 10 0 11 0 -13.4 0.1 -13.1 -13.7 04/08/2005 23:20:00 10.3 1 12.6 7.6 10.3 1 12.6 7.2 0.4 0 0.4 0.4 33 5 32 305 10 0 11 0 -13.4 0 -13.1 -13.7 04/08/2005 23:30:00 9.2 1 11.5 6.8 9.1 1.1 11.8 6.8 0.4 0 0.4 0.4 35 5 30 305 10 0 11 0 -13.3 0 -12.9 -13.5 04/08/2005 23:40:00 10.4 1 12.6 8 10.4 1 12.2 7.6 0.4 0 0.4 0.4 37 5 46 305 10 0 11 0 -13.4 0.1 -13.1 -13.7 04/08/2005 23:50:00 11.1 1 13.7 8.4 11.1 1.1 13.7 7.6 0.4 0 0.4 0.4 34 5 36 305 10 0 11 0 -13.5 0.1 -13.1 -13.7 04/09/2005 00:00:00 11.5 0.9 13.7 9.5 11.4 1 13.7 9.1 0.4 0 0.4 0.4 36 5 39 305 10 0 11 0 -13.5 0.1 -13.1 -13.7 04/09/2005 00:10:00 11.4 0.9 13.3 8.8 11.3 1 13.3 9.1 0.4 0 0.4 0.4 38 4 35 305 10 0 11 0 -13.5 0 -13.1 -13.7 04/09/2005 00:20:00 11.8 0.8 13.7 9.5 11.9 0.9 14.1 9.9 0.4 0 0.4 0.4 38 5 35 305 10 0 10 0 -13.4 0 -13.1 -13.7 04/09/2005 00:30:00 11.7 1 14.5 8.8 11.4 1.1 14.1 8.8 0.4 0 0.4 0.4 37 5 33 305 10 0 10 0 -13.5 0 -13.1 -13.7 04/09/2005 00:40:00 10.8 1.2 13.3 8 10.8 1.2 13.3 8 0.4 0 0.4 0.4 36 4 35 305 10 0 10 0 -13.4 0 -13.1 -13.5 04/09/2005 00:50:00 11.5 1 13.3 8.4 11.3 1.1 13.7 8 0.4 0 0.4 0.4 35 5 36 305 10 0 10 0 -13.4 0 -13.1 -13.7 04/09/2005 01:00:00 10.4 1.1 13 8 10.3 1.2 13 7.6 0.4 0 0.4 0.4 33 5 36 305 10 0 10 0 -13.5 0 -13.3 -13.7 04/09/2005 01:10:00 10.4 1.1 12.6 7.6 10.3 1.1 13 7.2 0.4 0 0.4 0.4 33 5 28 305 10 0 10 0 -13.5 0 -13.3 -13.7 04/09/2005 01:20:00 10.9 0.9 13.3 8 10.8 1 13.3 8 0.4 0 0.4 0.4 34 5 33 305 10 0 10 0 -13.5 0 -13.1 -13.7 04/09/2005 01:30:00 10.6 1 13 8 10.5 1 13 8 0.4 0 0.4 0.4 35 5 39 305 10 0 10 0 -13.4 0 -13.1 -13.7 04/09/2005 01:40:00 11.3 1.2 14.1 8 11.3 1.2 14.1 8 0.4 0 0.4 0.4 38 5 32 305 10 0 10 0 -13.4 0 -12.9 -13.5 04/09/2005 01:50:00 11.4 1.3 14.9 8 11.4 1.3 15.3 8.4 0.4 0 0.4 0.4 39 5 35 305 10 0 11 0 -13.3 0 -12.9 -13.5 04/09/2005 02:00:00 12 1.5 15.3 8.4 11.8 1.3 15.3 8 0.4 0 0.4 0.4 36 5 30 305 10 0 11 0 -13.2 0 -12.9 -13.5 04/09/2005 02:10:00 12.7 1.1 15.3 9.9 12.6 1.2 15.3 9.5 0.4 0 0.4 0.4 37 5 38 305 10 0 11 0 -13.3 0 -12.9 -13.5 04/09/2005 02:20:00 12.2 1.1 14.5 9.5 12.2 1.3 14.5 9.1 0.4 0 0.4 0.4 39 5 35 305 10 0 10 0 -13.2 0 -12.9 -13.3 04/09/2005 02:30:00 12.6 0.8 14.1 9.5 12.7 0.9 14.9 9.5 0.4 0 0.4 0.4 40 5 46 305 10 0 11 0 -13.3 0 -12.9 -13.3 04/09/2005 02:40:00 11.9 1 13.7 9.9 11.9 1.1 14.1 9.1 0.4 0 0.4 0.4 38 4 38 305 10 0 11 0 -13.3 0 -12.9 -13.5 04/09/2005 02:50:00 11.6 1.1 13.7 8.8 11.5 1.2 13.7 8.4 0.4 0 0.4 0.4 37 5 40 305 11 0 11 0 -13.2 0 -12.9 -13.3 04/09/2005 03:00:00 11 1 13 8 10.8 1.1 13.3 7.6 0.4 0 0.4 0.4 34 6 35 305 10 0 11 0 -13.2 0 -12.9 -13.3 04/09/2005 03:10:00 11.7 1.1 13.7 8.8 11.6 1.2 14.1 8.4 0.4 0 0.4 0.4 34 5 37 305 10 0 11 0 -13.3 0 -13.1 -13.3 04/09/2005 03:20:00 11.9 0.6 13.3 9.9 11.9 0.7 13.7 9.5 0.4 0 0.4 0.4 36 4 38 305 11 0 11 0 -13.2 0 -13.1 -13.3 04/09/2005 03:30:00 12 0.7 13.3 9.9 12 0.8 13.7 9.5 0.4 0 0.4 0.4 36 4 34 305 11 0 11 0 -13.2 0 -13.1 -13.3 04/09/2005 03:40:00 10 1 12.6 7.6 9.9 1 12.6 7.2 0.4 0 0.4 0.4 32 6 30 305 11 0 11 0 -13.2 0 -13.1 -13.3 04/09/2005 03:50:00 10.5 1 13.7 8 10.3 1 13.7 8 0.4 0 0.4 0.4 37 6 39 305 11 0 11 0 -13.2 0 -13.1 -13.3 04/09/2005 04:00:00 11.7 0.9 13.7 9.5 11.6 1.1 14.5 8.8 0.4 0 0.4 0.4 35 5 32 305 11 0 10 0 -13.2 0 -12.9 -13.3 04/09/2005 04:10:00 10.9 1 13 7.6 10.7 1.1 13 7.2 0.4 0 0.4 0.4 35 5 33 305 11 0 11 0 -13.2 0 -12.9 -13.3 04/09/2005 04:20:00 11.6 0.9 13.7 8.4 11.5 1 13.7 8.8 0.4 0 0.4 0.4 35 5 37 305 11 0 11 0 -13.3 0 -12.9 -13.3 04/09/2005 04:30:00 11.3 1.1 13.3 8.8 11.1 1.1 14.1 8 0.4 0 0.4 0.4 36 5 36 305 11 0 11 0 -13.2 0 -12.9 -13.5 04/09/2005 04:40:00 11.5 1.2 14.1 8 11.4 1.3 13.7 7.6 0.4 0 0.4 0.4 36 5 37 305 11 0 11 0 -13.1 0 -12.9 -13.3 04/09/2005 04:50:00 11.8 1 13.7 9.1 11.7 1 14.1 9.5 0.4 0 0.4 0.4 34 4 38 305 11 0 11 0 -13.1 0 -12.7 -13.3 04/09/2005 05:00:00 11.7 1.1 13.7 9.1 11.5 1.2 14.1 8.8 0.4 0 0.4 0.4 37 6 35 305 11 0 11 0 -13.1 0 -12.7 -13.3 04/09/2005 05:10:00 12.1 1.2 14.5 9.1 12 1.2 14.5 9.1 0.4 0 0.4 0.4 39 5 43 305 11 0 11 0 -13 0 -12.5 -13.3 04/09/2005 05:20:00 12.2 0.9 14.9 9.5 12 1 14.5 8.8 0.4 0 0.4 0.4 38 5 37 305 11 0 11 0 -13 0.1 -12.5 -13.1 04/09/2005 05:30:00 13 0.9 14.9 10.3 12.9 1 14.9 9.9 0.4 0 0.4 0.4 37 4 37 305 11 0 11 0 -13.1 0 -12.7 -13.3 04/09/2005 05:40:00 11.1 0.9 13.7 8.8 11.1 1 14.5 8.8 0.4 0 0.4 0.4 37 5 40 305 11 0 11 0 -13 0.1 -12.5 -13.1 04/09/2005 05:50:00 11.6 1.2 14.9 8.8 11.6 1.2 14.5 9.1 0.4 0 0.4 0.4 36 5 33 305 11 0 11 0 -13.1 0 -12.7 -13.3 04/09/2005 06:00:00 11.6 1.3 14.1 7.2 11.5 1.5 14.1 6.8 0.4 0 0.4 0.4 38 4 43 305 11 0 11 0 -13 0 -12.7 -13.3 04/09/2005 06:10:00 11.5 1.3 14.5 8.4 11.4 1.5 14.1 7.2 0.4 0 0.4 0.4 36 5 38 305 11 0 11 0 -13.1 0 -12.5 -13.3 04/09/2005 06:20:00 12.7 1 14.9 9.5 12.6 1.1 14.9 9.1 0.4 0 0.4 0.4 36 5 40 305 11 0 11 0 -13.1 0 -12.9 -13.3 04/09/2005 06:30:00 12.2 0.9 13.7 9.5 12.1 1 14.1 8.8 0.4 0 0.4 0.4 39 5 37 305 11 0 11 0 -13.1 0 -12.7 -13.3 04/09/2005 06:40:00 12.1 0.9 14.1 9.5 11.9 1 14.1 9.1 0.4 0 0.4 0.4 34 4 31 305 11 0 11 0 -13.1 0 -12.9 -13.3 04/09/2005 06:50:00 12 1 13.7 9.5 11.8 1 14.1 8.8 0.4 0 0.4 0.4 37 5 38 305 11 0 11 0 -13.1 0 -12.9 -13.3 04/09/2005 07:00:00 11 1 13 8.8 10.9 1.1 13.3 7.6 0.4 0 0.4 0.4 37 5 44 305 11 0 11 0 -13.1 0 -12.7 -13.3 04/09/2005 07:10:00 11.6 1 13.7 9.1 11.5 1.1 14.1 9.1 0.4 0 0.4 0.4 38 4 37 305 11 0 11 0 -13.2 0 -12.9 -13.3 04/09/2005 07:20:00 11.9 0.8 13.3 8.8 11.8 1 13.7 8.8 0.4 0 0.4 0.4 41 4 45 305 11 0 11 0 -13.1 0 -12.9 -13.3 04/09/2005 07:30:00 11.7 0.9 13.7 9.5 11.6 1 13.7 8.8 0.4 0 0.4 0.4 39 4 41 305 11 0 11 0 -13.1 0 -12.9 -13.3 04/09/2005 07:40:00 11.7 0.7 13.3 9.5 11.6 0.8 13.3 9.5 0.4 0 0.4 0.4 37 5 42 305 11 0 11 0 -13.1 0 -12.9 -13.1 04/09/2005 07:50:00 11.8 1.2 13.7 8.4 11.7 1.3 13.7 8 0.4 0 0.4 0.4 34 4 40 305 11 0 11 0 -13 0 -12.9 -13.3 04/09/2005 08:00:00 12.1 0.8 14.1 9.9 12 1 14.5 9.5 0.4 0 0.4 0.4 36 4 32 305 11 0 11 0 -13 0.1 -12.5 -13.3 04/09/2005 08:10:00 12.8 1.1 15.3 9.9 12.8 1.3 15.3 9.5 0.4 0 0.4 0.4 41 4 43 305 11 0 11 0 -13 0 -12.7 -13.1 04/09/2005 08:20:00 11.9 0.8 13.7 9.5 11.8 0.9 13.7 9.5 0.4 0 0.4 0.4 36 4 33 305 11 0 11 0 -12.9 0.1 -12.5 -13.1 04/09/2005 08:30:00 12.7 0.8 14.1 10.3 12.6 0.8 14.1 9.9 0.4 0 0.4 0.4 35 4 33 305 11 0 11 0 -13 0 -12.7 -13.1 04/09/2005 08:40:00 12.1 0.8 13.7 9.9 12.1 0.9 14.5 9.9 0.4 0 0.4 0.4 43 5 39 305 11 0 11 0 -13 0.1 -12.5 -13.1 04/09/2005 08:50:00 12.4 1 14.5 9.9 12.3 1.1 14.5 9.1 0.4 0 0.4 0.4 39 5 36 305 11 0 11 0 -13 0 -12.5 -13.1 04/09/2005 09:00:00 13.5 0.8 15.3 11.5 13.4 1 15.6 10.7 0.4 0 0.4 0.4 36 4 33 305 11 0 11 0 -13 0 -12.5 -13.1 04/09/2005 09:10:00 12.7 0.7 14.1 10.7 12.5 0.8 14.1 9.9 0.4 0 0.4 0.4 35 3 35 305 11 0 11 0 -13 0 -12.9 -13.1 04/09/2005 09:20:00 12.3 0.5 13.7 10.7 12.2 0.6 13.7 11.1 0.4 0 0.4 0.4 34 2 35 305 11 0 11 0 -13 0 -12.5 -13.3 04/09/2005 09:30:00 11.6 0.6 13 9.5 11.4 0.7 13.3 9.1 0.4 0 0.4 0.4 34 3 35 305 11 0 12 0 -13 0 -12.7 -13.3 04/09/2005 09:40:00 11.7 0.7 13.3 9.5 11.7 0.8 13.3 8.8 0.4 0 0.4 0.4 34 3 29 305 12 0 12 0 -13 0.1 -12.5 -13.1 04/09/2005 09:50:00 12 0.8 13.3 9.9 11.9 0.9 13.3 9.1 0.4 0 0.4 0.4 33 3 29 305 12 0 12 0 -13.1 0 -12.7 -13.3 04/09/2005 10:00:00 12.2 0.9 13.7 9.9 12.1 1 13.7 9.5 0.4 0 0.4 0.4 35 3 38 305 12 0 12 0 -13 0 -12.5 -13.1 04/09/2005 10:10:00 12.7 0.8 14.5 10.7 12.6 0.9 14.9 10.7 0.4 0 0.4 0.4 34 5 39 305 12 0 12 0 -12.9 0.1 -12.5 -13.1 04/09/2005 10:20:00 12.4 0.8 14.5 9.9 12.4 0.9 14.1 9.9 0.4 0 0.4 0.4 35 4 33 305 12 0 12 0 -13 0 -12.5 -13.3 04/09/2005 10:30:00 12.9 0.8 14.9 10.7 12.6 0.9 14.9 10.7 0.4 0 0.4 0.4 28 4 24 305 13 0 13 0 -12.9 0.1 -12.5 -13.1 04/09/2005 10:40:00 12.5 0.8 14.1 10.3 12.3 0.8 14.1 9.9 0.4 0 0.4 0.4 27 4 28 305 13 0 13 0 -13 0 -12.5 -13.1 04/09/2005 10:50:00 12.5 0.8 14.5 9.9 12.3 0.9 14.5 9.5 0.4 0 0.4 0.4 27 3 33 305 13 0 13 0 -13.1 0 -12.7 -13.3 04/09/2005 11:00:00 12.9 1.2 15.6 9.9 12.8 1.2 15.6 9.5 0.4 0 0.4 0.4 27 4 29 305 13 0 13 0 -13 0 -12.5 -13.3 04/09/2005 11:10:00 12.8 1 15.6 10.7 12.6 1 15.3 9.9 0.4 0 0.4 0.4 28 5 31 305 13 0 13 0 -12.8 0 -12.5 -13.1 04/09/2005 11:20:00 12.4 1.1 14.5 9.5 12.3 1.2 14.9 9.1 0.4 0 0.4 0.4 27 5 31 305 13 0 13 0 -12.6 0 -12.1 -12.9 04/09/2005 11:30:00 12.5 1 14.5 8.8 12.4 1 14.5 9.5 0.4 0 0.4 0.4 22 4 25 305 14 0 14 0 -12.8 0.1 -12.3 -12.9 04/09/2005 11:40:00 12 0.9 13.7 9.5 11.9 1 13.7 9.1 0.4 0 0.4 0.4 14 4 22 305 14 0 14 0 -12.9 0.2 -12.5 -13.3 04/09/2005 11:50:00 12.5 0.7 13.7 10.3 12.5 0.7 14.5 10.3 0.4 0 0.4 0.4 14 3 13 305 14 0 14 0 -13.3 0 -13.1 -13.5 04/09/2005 12:00:00 11.8 0.8 13.3 9.1 11.7 0.8 13.3 9.5 0.4 0 0.4 0.4 14 4 28 305 14 0 14 0 -13.1 0.1 -12.7 -13.5 04/09/2005 12:10:00 12.1 0.8 14.1 9.9 12.1 0.8 14.1 9.9 0.4 0 0.4 0.4 15 4 19 305 14 0 14 0 -13.1 0 -12.9 -13.3 04/09/2005 12:20:00 12 1 14.1 9.5 12 1 13.7 9.1 0.4 0 0.4 0.4 15 4 23 305 14 0 14 0 -13.1 0.1 -12.9 -13.5 04/09/2005 12:30:00 12 0.8 13.7 10.3 12 0.9 14.1 9.5 0.4 0 0.4 0.4 14 3 14 305 14 0 14 0 -13.2 0 -13.1 -13.3 04/09/2005 12:40:00 12 0.7 13.3 9.9 11.9 0.7 13.3 9.9 0.4 0 0.4 0.4 16 3 18 305 14 0 14 0 -13.2 0.1 -12.9 -13.5 04/09/2005 12:50:00 12.2 0.6 13.3 10.3 12.2 0.7 13.7 9.9 0.4 0 0.4 0.4 13 3 15 305 14 0 14 0 -13.3 0 -13.1 -13.5 04/09/2005 13:00:00 11.7 0.6 13 9.9 11.8 0.6 13.3 9.5 0.4 0 0.4 0.4 13 3 11 305 14 0 14 0 -13.2 0 -13.1 -13.3 04/09/2005 13:10:00 11.4 0.7 13.3 9.5 11.5 0.6 13.3 9.5 0.4 0 0.4 0.4 15 4 13 305 14 0 14 0 -13.2 0 -12.9 -13.3 04/09/2005 13:20:00 11.8 0.9 13.3 8.8 11.8 1 13.7 9.1 0.4 0 0.4 0.4 13 3 14 305 14 0 14 0 -13.3 0 -13.1 -13.5 04/09/2005 13:30:00 11.7 0.8 13.3 9.1 11.7 0.8 13.7 9.9 0.4 0 0.4 0.4 12 3 10 305 14 0 14 0 -13.2 0 -12.9 -13.5 04/09/2005 13:40:00 11.6 0.9 13.3 9.1 11.6 0.9 13.7 9.1 0.4 0 0.4 0.4 11 5 9 305 14 0 14 0 -13.2 0.1 -12.9 -13.5 04/09/2005 13:50:00 12.3 0.7 13.3 9.5 12.3 0.7 13.7 10.3 0.4 0 0.4 0.4 9 3 9 305 14 0 14 0 -13.5 0 -13.1 -13.7 04/09/2005 14:00:00 12.7 0.7 14.1 9.9 12.6 0.8 14.1 9.5 0.4 0 0.4 0.4 11 3 8 305 13 0 14 0 -13.5 0.1 -12.9 -13.7 04/09/2005 14:10:00 12.4 0.9 14.1 9.9 12.3 1 14.5 8.8 0.4 0 0.4 0.4 13 4 17 305 13 0 13 0 -13.3 0 -12.9 -13.5 04/09/2005 14:20:00 11.8 1.1 13.7 9.1 11.8 1.1 13.7 8.8 0.4 0 0.4 0.4 13 5 11 305 13 0 13 0 -13.3 0 -12.9 -13.5 04/09/2005 14:30:00 11.9 0.8 13.3 9.5 11.8 0.9 13.7 9.1 0.4 0 0.4 0.4 9 4 10 305 14 0 14 0 -13.3 0 -12.9 -13.5 04/09/2005 14:40:00 11.2 0.8 13.3 9.1 11.1 0.9 13.7 9.1 0.4 0 0.4 0.4 11 5 23 305 14 0 14 0 -13.3 0.1 -12.9 -13.5 04/09/2005 14:50:00 11.9 1 13.7 8.4 11.9 1 14.1 9.1 0.4 0 0.4 0.4 7 4 6 305 14 0 14 0 -13.6 0 -13.3 -13.7 04/09/2005 15:00:00 11.5 1 13.3 8.8 11.5 1.1 13.3 8.4 0.4 0 0.4 0.4 10 5 8 305 13 0 13 0 -13.5 0.1 -12.9 -13.7 04/09/2005 15:10:00 12.3 1 14.1 9.5 12.3 1 14.9 9.1 0.4 0 0.4 0.4 11 5 8 305 13 0 13 0 -13.6 0.1 -13.1 -13.7 04/09/2005 15:20:00 11.3 1 13.7 8.8 11.2 1 13.3 8.8 0.4 0 0.4 0.4 13 5 13 305 13 0 13 0 -13.5 0.1 -13.1 -13.7 04/09/2005 15:30:00 12 1.1 14.1 8.8 11.9 1.1 14.1 8.4 0.4 0 0.4 0.4 12 4 10 305 13 0 13 0 -13.5 0.1 -13.1 -13.7 04/09/2005 15:40:00 11.9 0.8 13.7 9.1 11.8 0.9 13.7 9.5 0.4 0 0.4 0.4 11 4 10 305 13 0 13 0 -13.6 0 -13.3 -13.7 04/09/2005 15:50:00 12 0.7 13.7 9.5 12 0.8 13.7 9.9 0.4 0 0.4 0.4 9 3 9 305 13 0 13 0 -13.6 0 -13.3 -13.7 04/09/2005 16:00:00 11.7 0.9 14.1 9.1 11.7 0.9 14.1 9.5 0.4 0 0.4 0.4 6 4 4 305 13 0 13 0 -13.5 0.1 -13.1 -13.7 04/09/2005 16:10:00 11 1.1 13.3 8.4 11 1.2 13.7 8.4 0.4 0 0.4 0.4 6 5 2 305 13 0 13 0 -13.5 0.1 -13.1 -13.7 04/09/2005 16:20:00 10.8 1 13.3 8 10.8 1.1 13.3 8 0.4 0 0.4 0.4 9 5 12 305 13 0 13 0 -13.4 0 -13.1 -13.5 04/09/2005 16:30:00 10.5 1 12.6 8 10.5 1 13 7.6 0.4 0 0.4 0.4 8 5 3 305 13 0 13 0 -13.3 0 -12.9 -13.5 04/09/2005 16:40:00 10.9 1.1 13.7 8.8 10.8 1.1 13.7 8.8 0.4 0 0.4 0.4 14 5 18 305 13 0 13 0 -13.3 0 -13.1 -13.5 04/09/2005 16:50:00 11.8 0.9 13.7 9.5 11.7 1 13.7 8.8 0.4 0 0.4 0.4 16 4 14 305 13 0 13 0 -13.2 0 -13.1 -13.3 04/09/2005 17:00:00 11.4 1.1 13.7 8.4 11.3 1.1 13.3 8.8 0.4 0 0.4 0.4 12 3 17 305 13 0 13 0 -13.2 0 -12.9 -13.5 04/09/2005 17:10:00 11.4 0.7 13 8.4 11.4 0.8 13.3 8.8 0.4 0 0.4 0.4 9 3 7 305 13 0 13 0 -13.1 0 -12.9 -13.3 04/09/2005 17:20:00 10.8 0.8 12.6 8.4 10.8 0.9 13 8.4 0.4 0 0.4 0.4 13 5 16 305 14 0 14 0 -13 0 -12.9 -13.3 04/09/2005 17:30:00 10.9 1.2 13.3 7.2 10.8 1.2 13 7.6 0.4 0 0.4 0.4 11 5 8 305 14 0 13 0 -13 0 -12.7 -13.3 04/09/2005 17:40:00 11.4 1 13.3 8.4 11.4 1.2 13.3 8 0.4 0 0.4 0.4 11 5 10 305 14 0 13 0 -13 0 -12.7 -13.1 04/09/2005 17:50:00 11.2 1 13 8.4 11.1 1 13.3 8.8 0.4 0 0.4 0.4 13 4 10 305 14 0 14 0 -12.9 0 -12.7 -13.1 04/09/2005 18:00:00 10.9 0.9 13 8.4 10.8 1 13 8 0.4 0 0.4 0.4 12 4 11 305 14 0 14 0 -13 0 -12.7 -13.1 04/09/2005 18:10:00 11.7 0.8 13.3 9.5 11.7 0.9 13.7 9.1 0.4 0 0.4 0.4 12 4 11 305 14 0 14 0 -13 0 -12.9 -13.3 04/09/2005 18:20:00 11.5 1 13.7 9.1 11.5 1 13.7 8.8 0.4 0 0.4 0.4 12 4 10 305 14 0 13 0 -13 0 -12.9 -13.3 04/09/2005 18:30:00 11.8 0.9 13.7 8.8 11.6 1 14.1 8.8 0.4 0 0.4 0.4 12 4 11 305 13 0 13 0 -13.1 0 -12.7 -13.3 04/09/2005 18:40:00 12.1 1.1 14.5 9.5 12 1.2 14.5 9.1 0.4 0 0.4 0.4 10 4 8 305 13 0 13 0 -13.1 0 -12.7 -13.3 04/09/2005 18:50:00 12.3 1 14.5 9.1 12.3 1 14.5 9.1 0.4 0 0.4 0.4 12 4 14 305 13 0 13 0 -13.1 0 -12.7 -13.3 04/09/2005 19:00:00 11.6 1 13.7 9.1 11.5 1 13.7 8.8 0.4 0 0.4 0.4 11 5 14 305 13 0 13 0 -13.1 0 -12.7 -13.3 04/09/2005 19:10:00 12 1 14.1 9.1 11.8 1 14.1 8.8 0.4 0 0.4 0.4 12 4 15 305 13 0 13 0 -13.1 0 -12.7 -13.3 04/09/2005 19:20:00 11.6 1.1 14.5 9.1 11.6 1.1 14.5 8.8 0.4 0 0.4 0.4 14 4 14 305 13 0 13 0 -13.1 0 -12.7 -13.3 04/09/2005 19:30:00 11.8 0.9 14.1 9.5 11.7 0.9 14.1 9.5 0.4 0 0.4 0.4 15 4 13 305 13 0 13 0 -13.1 0 -12.7 -13.3 04/09/2005 19:40:00 11.8 1 13.7 8.4 11.7 1 14.1 9.1 0.4 0 0.4 0.4 12 4 9 305 13 0 13 0 -13 0 -12.7 -13.3 04/09/2005 19:50:00 11.4 1.1 13.7 8.4 11.3 1.1 13.7 8.4 0.4 0 0.4 0.4 13 3 14 305 13 0 13 0 -13.1 0 -12.7 -13.3 04/09/2005 20:00:00 11.3 0.9 13.3 8.8 11.2 0.9 13 8.8 0.4 0 0.4 0.4 13 4 14 305 13 0 13 0 -13 0 -12.7 -13.3 04/09/2005 20:10:00 11.1 0.8 13 9.1 11 0.9 13 8.4 0.4 0 0.4 0.4 12 4 7 305 12 0 13 0 -13 0.1 -12.7 -13.1 04/09/2005 20:20:00 10.4 0.8 12.2 8 10.3 0.8 12.2 8 0.4 0 0.4 0.4 11 4 7 305 12 0 12 0 -13 0 -12.7 -13.1 04/09/2005 20:30:00 11.3 1 13.7 8.4 11.2 1.1 13.7 8.4 0.4 0 0.4 0.4 14 5 12 305 12 0 12 0 -13 0 -12.7 -13.1 04/09/2005 20:40:00 10.6 0.7 12.2 8 10.6 0.8 12.6 8 0.4 0 0.4 0.4 12 4 16 305 12 0 12 0 -13.1 0 -12.7 -13.1 04/09/2005 20:50:00 11.9 1 13.7 9.5 11.8 1 13.7 9.5 0.4 0 0.4 0.4 11 4 9 305 12 0 12 0 -13.1 0 -12.9 -13.3 04/09/2005 21:00:00 11.9 1.1 14.1 8.4 11.8 1.1 14.1 8.4 0.4 0 0.4 0.4 11 4 12 305 12 0 12 0 -13.1 0 -12.9 -13.3 04/09/2005 21:10:00 11.8 1 14.1 9.1 11.6 1.1 14.5 8.4 0.4 0 0.4 0.4 11 4 11 305 12 0 12 0 -13.2 0 -12.9 -13.3 04/09/2005 21:20:00 12 0.9 13.7 9.9 12 0.9 14.1 9.5 0.4 0 0.4 0.4 11 4 13 305 12 0 12 0 -13.2 0 -13.1 -13.3 04/09/2005 21:30:00 11.9 1 14.1 9.1 11.7 1.1 14.1 8.4 0.4 0 0.4 0.4 12 4 12 305 12 0 12 0 -13.3 0 -13.1 -13.5 04/09/2005 21:40:00 11.7 1 13.7 8.8 11.6 1.1 13.7 8 0.4 0 0.4 0.4 11 4 14 305 12 0 12 0 -13.4 0 -13.3 -13.5 04/09/2005 21:50:00 11.1 1 13 8.4 10.9 1.1 13.3 8 0.4 0 0.4 0.4 12 4 9 305 12 0 12 0 -13.4 0 -13.3 -13.5 04/09/2005 22:00:00 11.7 1.2 14.9 8.8 11.5 1.3 14.9 8 0.4 0 0.4 0.4 12 5 10 305 12 0 12 0 -13.4 0 -12.9 -13.5 04/09/2005 22:10:00 12.6 1.1 14.5 9.5 12.5 1.1 14.9 9.9 0.4 0 0.4 0.4 13 4 12 305 11 0 11 0 -13.5 0 -13.3 -13.7 04/09/2005 22:20:00 11.5 1 13.7 8.4 11.4 1 13.7 8.8 0.4 0 0.4 0.4 11 4 7 305 11 0 11 0 -13.5 0 -13.3 -13.7 04/09/2005 22:30:00 11.5 1 13.7 9.1 11.4 1 13.7 8.8 0.4 0 0.4 0.4 12 5 12 305 11 0 11 0 -13.4 0 -13.3 -13.7 04/09/2005 22:40:00 12 1.1 14.5 8.8 11.9 1.2 14.9 8.8 0.4 0 0.4 0.4 11 4 12 305 11 0 11 0 -13.4 0 -13.3 -13.7 04/09/2005 22:50:00 13 0.8 15.3 10.3 13 0.9 15.3 10.7 0.4 0 0.4 0.4 9 3 10 305 11 0 11 0 -13.5 0 -13.3 -13.7 04/09/2005 23:00:00 12 1.2 14.5 9.1 11.9 1.3 14.5 9.5 0.4 0 0.4 0.4 10 4 13 305 11 0 11 0 -13.4 0 -12.9 -13.5 04/09/2005 23:10:00 12.5 1 14.9 9.5 12.4 1 14.9 9.5 0.4 0 0.4 0.4 9 3 4 305 11 0 11 0 -13.4 0 -13.1 -13.5 04/09/2005 23:20:00 11.8 1.1 14.1 8.8 11.7 1.1 14.1 9.1 0.4 0 0.4 0.4 7 5 13 305 11 0 11 0 -13.3 0.1 -12.9 -13.7 04/09/2005 23:30:00 10.9 1 13.3 8 10.8 1 14.1 8.4 0.4 0 0.4 0.4 3 4 5 305 11 0 11 0 -13.6 0 -13.1 -13.7 04/09/2005 23:40:00 11.7 1 13.7 8.8 11.7 1 13.7 8.8 0.4 0 0.4 0.4 6 3 7 305 11 0 11 0 -13.6 0 -13.3 -13.7 04/09/2005 23:50:00 11.7 0.8 13.3 9.5 11.6 0.9 13.7 8.8 0.4 0 0.4 0.4 7 5 12 305 11 0 11 0 -13.6 0 -13.3 -13.7 04/10/2005 00:00:00 11.6 0.9 13.7 9.5 11.6 0.9 14.1 9.5 0.4 0 0.4 0.4 6 3 8 305 11 0 11 0 -13.7 0 -13.3 -13.7 04/10/2005 00:10:00 11.5 1 13.7 9.1 11.4 1 13.7 8.8 0.4 0 0.4 0.4 8 4 7 305 11 0 11 0 -13.6 0 -13.3 -13.7 04/10/2005 00:20:00 11.8 0.8 14.1 9.5 11.8 0.9 14.5 9.5 0.4 0 0.4 0.4 7 3 5 305 11 0 11 0 -13.5 0 -13.3 -13.7 04/10/2005 00:30:00 12.7 0.9 14.9 9.9 12.5 0.9 14.9 10.3 0.4 0 0.4 0.4 9 3 12 305 11 0 11 0 -13.6 0 -13.3 -13.7 04/10/2005 00:40:00 13 1 15.3 9.5 12.9 1 15.3 10.7 0.4 0 0.4 0.4 11 4 8 305 11 0 11 0 -13.6 0 -13.3 -13.7 04/10/2005 00:50:00 12.2 0.9 14.5 9.5 12.2 0.9 14.5 9.9 0.4 0 0.4 0.4 9 4 7 305 11 0 11 0 -13.5 0 -13.3 -13.7 04/10/2005 01:00:00 11.9 0.9 14.1 9.5 11.9 1 15.3 9.5 0.4 0 0.4 0.4 9 4 14 305 11 0 11 0 -13.7 0 -13.5 -13.7 04/10/2005 01:10:00 12.4 1 14.5 9.1 12.4 1.2 14.9 9.5 0.4 0 0.4 0.4 8 3 5 305 11 0 11 0 -13.6 0 -13.5 -13.7 04/10/2005 01:20:00 12.5 0.9 14.9 9.5 12.5 0.9 14.9 9.9 0.4 0 0.4 0.4 7 4 11 305 11 0 11 0 -13.5 0.1 -13.1 -13.7 04/10/2005 01:30:00 12.3 1.1 14.5 9.1 12.3 1.2 14.5 9.5 0.4 0 0.4 0.4 7 4 10 305 11 0 11 0 -13.3 0 -12.9 -13.5 04/10/2005 01:40:00 13 0.8 14.5 11.1 12.9 1 14.9 10.3 0.4 0 0.4 0.4 9 3 9 305 11 0 11 0 -13.4 0 -12.9 -13.5 04/10/2005 01:50:00 13 0.9 14.5 9.9 13 1 14.9 9.9 0.4 0 0.4 0.4 8 5 12 305 11 0 11 0 -13.4 0.1 -13.1 -13.7 04/10/2005 02:00:00 12.1 1.2 14.5 8.4 12.2 1.3 14.5 8.4 0.4 0 0.4 0.4 7 4 5 305 11 0 11 0 -13.4 0 -13.1 -13.7 04/10/2005 02:10:00 11.6 1.1 13.7 8.8 11.6 1 14.1 8.8 0.4 0 0.4 0.4 9 5 11 305 11 0 11 0 -13.3 0 -12.9 -13.5 04/10/2005 02:20:00 12 0.9 13.7 9.1 11.9 1 14.1 9.1 0.4 0 0.4 0.4 12 3 11 305 11 0 11 0 -13.2 0.1 -12.9 -13.5 04/10/2005 02:30:00 12.2 0.8 13.7 9.9 12 0.9 14.1 9.5 0.4 0 0.4 0.4 11 4 12 305 11 0 11 0 -13.1 0.1 -12.9 -13.3 04/10/2005 02:40:00 12.2 1 14.1 9.5 12.3 1 14.1 9.1 0.4 0 0.4 0.4 10 4 6 305 11 0 11 0 -13.1 0 -12.7 -13.3 04/10/2005 02:50:00 12.4 1 14.1 9.9 12.3 1 14.1 9.5 0.4 0 0.4 0.4 16 4 11 305 11 0 11 0 -13 0.1 -12.5 -13.3 04/10/2005 03:00:00 11.3 1 13.3 8.4 11.1 1 13.7 8.4 0.4 0 0.4 0.4 17 4 17 305 11 0 11 0 -12.9 0.1 -12.5 -13.1 04/10/2005 03:10:00 11.9 0.8 13.7 9.5 11.9 1 14.1 9.1 0.4 0 0.4 0.4 15 4 18 305 11 0 11 0 -12.8 0 -12.5 -12.9 04/10/2005 03:20:00 13 1.1 15.3 10.3 12.9 1.2 15.6 10.3 0.4 0 0.4 0.4 16 5 16 305 12 0 12 0 -12.8 0.1 -12.5 -13.1 04/10/2005 03:30:00 12.5 1.3 15.3 9.5 12.5 1.2 15.3 9.5 0.4 0 0.4 0.4 16 4 17 305 12 0 12 0 -12.8 0 -12.5 -12.9 04/10/2005 03:40:00 13.1 0.9 15.3 10.3 12.9 1 15.3 10.3 0.4 0 0.4 0.4 16 4 18 305 12 0 12 0 -12.9 0 -12.7 -12.9 04/10/2005 03:50:00 12.7 1.1 15.3 10.3 12.6 1.1 15.6 9.9 0.4 0 0.4 0.4 14 4 14 305 12 0 12 0 -12.8 0 -12.5 -12.9 04/10/2005 04:00:00 12.9 1 14.9 9.5 12.7 1.1 14.9 9.1 0.4 0 0.4 0.4 10 4 11 305 12 0 12 0 -12.9 0 -12.7 -12.9 04/10/2005 04:10:00 11.6 1 13.7 8.8 11.5 1 14.1 8 0.4 0 0.4 0.4 11 4 7 305 12 0 11 0 -12.9 0 -12.7 -13.1 04/10/2005 04:20:00 11.6 0.9 13.3 8.4 11.4 1 14.1 8.4 0.4 0 0.4 0.4 9 3 9 305 12 0 12 0 -12.8 0 -12.5 -12.9 04/10/2005 04:30:00 11.9 0.9 13.7 9.5 11.9 1 13.7 9.1 0.4 0 0.4 0.4 12 5 8 305 12 0 12 0 -12.8 0 -12.5 -12.9 04/10/2005 04:40:00 12.1 0.8 13.7 9.9 12 0.9 14.1 9.5 0.4 0 0.4 0.4 15 4 19 305 12 0 12 0 -12.8 0 -12.7 -12.9 04/10/2005 04:50:00 11.6 1 14.1 8.8 11.5 1.1 14.1 8.4 0.4 0 0.4 0.4 13 4 16 305 12 0 12 0 -12.9 0 -12.7 -12.9 04/10/2005 05:00:00 11.7 0.8 14.1 9.5 11.6 1 14.1 9.1 0.4 0 0.4 0.4 18 4 13 305 12 0 12 0 -13 0 -12.9 -13.1 04/10/2005 05:10:00 11.7 0.9 13.3 8.8 11.7 1 13.7 8.8 0.4 0 0.4 0.4 20 4 16 305 12 0 12 0 -13.1 0 -12.9 -13.3 04/10/2005 05:20:00 10.6 1.2 13 8.4 10.5 1.3 13.3 7.2 0.4 0 0.4 0.4 17 5 20 305 12 0 12 0 -13.1 0 -12.9 -13.3 04/10/2005 05:30:00 11.4 1 13.7 8.4 11.3 0.9 13.3 8.8 0.4 0 0.4 0.4 19 4 21 305 12 0 12 0 -13 0 -12.9 -13.1 04/10/2005 05:40:00 10.3 1.2 13 7.6 10.3 1.2 12.6 7.6 0.4 0 0.4 0.4 20 4 21 305 12 0 12 0 -12.8 0 -12.7 -12.9 04/10/2005 05:50:00 9.6 1 11.8 7.2 9.5 1 12.2 7.6 0.4 0 0.4 0.4 19 5 23 305 12 0 12 0 -12.6 0 -12.3 -12.9 04/10/2005 06:00:00 9.9 0.8 11.8 7.6 9.8 0.9 11.8 8 0.4 0 0.4 0.4 17 5 14 305 12 0 12 0 -12.7 0 -12.3 -12.9 04/10/2005 06:10:00 10.4 0.9 12.2 8 10.3 0.9 12.2 8 0.4 0 0.4 0.4 17 4 15 305 12 0 12 0 -12.7 0 -12.5 -12.9 04/10/2005 06:20:00 10.4 1.1 12.2 7.2 10.4 1.2 12.6 7.2 0.4 0 0.4 0.4 14 5 15 305 12 0 12 0 -12.7 0 -12.3 -12.9 04/10/2005 06:30:00 9.8 0.8 12.2 7.6 9.6 0.9 11.8 7.6 0.4 0 0.4 0.4 16 4 14 305 12 0 12 0 -12.8 0.1 -12.5 -12.9 04/10/2005 06:40:00 10.5 0.8 12.2 8.4 10.3 0.8 11.8 7.6 0.4 0 0.4 0.4 15 4 13 305 12 0 12 0 -12.9 0.1 -12.5 -13.1 04/10/2005 06:50:00 10.7 1 13 8.4 10.5 1 13 8.4 0.4 0 0.4 0.4 15 4 13 305 12 0 12 0 -13.1 0 -12.7 -13.3 04/10/2005 07:00:00 9.1 0.8 11.1 6.8 8.9 0.7 10.7 7.2 0.4 0 0.4 0.4 18 5 25 305 12 0 12 0 -13 0 -12.7 -13.3 04/10/2005 07:10:00 9.4 0.8 11.1 7.2 9.3 0.8 11.5 7.2 0.4 0 0.4 0.4 17 4 17 305 12 0 12 0 -13 0.1 -12.5 -13.1 04/10/2005 07:20:00 9.2 0.8 11.1 6.8 9 0.9 11.1 6.5 0.4 0 0.4 0.4 15 3 15 305 12 0 12 0 -13 0 -12.7 -13.3 04/10/2005 07:30:00 9.6 0.8 11.1 6.8 9.4 0.8 11.5 6.8 0.4 0 0.4 0.4 16 3 17 305 12 0 12 0 -13.1 0 -12.9 -13.3 04/10/2005 07:40:00 9.4 0.8 11.5 7.2 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 17 4 18 305 12 0 12 0 -13.3 0 -12.9 -13.5 04/10/2005 07:50:00 9.6 0.9 11.8 7.2 9.5 0.9 11.8 7.2 0.4 0 0.4 0.4 21 4 19 305 12 0 12 0 -13.3 0.1 -12.9 -13.5 04/10/2005 08:00:00 8.9 0.7 10.7 7.2 8.6 0.7 11.1 6.5 0.4 0 0.4 0.4 20 4 22 305 12 0 12 0 -13.3 0 -12.9 -13.5 04/10/2005 08:10:00 8.2 0.8 10.3 6.1 8 0.8 10.3 6.1 0.4 0 0.4 0.4 16 4 16 305 12 0 12 0 -13.2 0 -13.1 -13.3 04/10/2005 08:20:00 8.5 0.9 10.7 6.1 8.3 0.9 10.7 6.1 0.4 0 0.4 0.4 16 5 10 305 12 0 12 0 -13 0 -12.9 -13.3 04/10/2005 08:30:00 9 0.8 10.3 6.5 8.9 0.8 10.3 6.5 0.4 0 0.4 0.4 20 4 16 305 12 0 12 0 -13.1 0 -12.9 -13.3 04/10/2005 08:40:00 8.5 1 11.1 6.1 8.5 0.9 11.1 6.1 0.4 0 0.4 0.4 20 4 25 305 12 0 12 0 -13.1 0 -12.9 -13.3 04/10/2005 08:50:00 8.9 0.7 10.3 6.5 8.7 0.7 10.3 6.8 0.4 0 0.4 0.4 19 4 21 305 12 0 12 0 -13.1 0 -12.9 -13.3 04/10/2005 09:00:00 8.7 0.7 10.3 6.5 8.6 0.7 9.9 6.8 0.4 0 0.4 0.4 18 4 18 305 12 0 12 0 -13 0 -12.9 -13.1 04/10/2005 09:10:00 8.6 0.6 9.9 6.8 8.5 0.6 10.7 6.8 0.4 0 0.4 0.4 19 4 16 305 12 0 12 0 -13 0 -12.9 -13.1 04/10/2005 09:20:00 8.6 0.7 9.9 6.5 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 20 3 20 305 12 0 12 0 -12.9 0 -12.7 -13.1 04/10/2005 09:30:00 7.9 0.7 9.5 6.5 7.8 0.7 9.5 6.5 0.4 0 0.4 0.4 22 5 16 305 12 0 12 0 -12.7 0 -12.5 -12.9 04/10/2005 09:40:00 7.9 0.8 9.9 6.1 7.8 0.8 9.9 6.1 0.4 0 0.4 0.4 23 5 24 305 13 0 13 0 -12.6 0 -12.5 -12.9 04/10/2005 09:50:00 8.9 0.8 10.7 6.8 8.7 0.8 11.1 6.5 0.4 0 0.4 0.4 24 5 24 305 13 0 13 0 -12.6 0 -12.3 -12.7 04/10/2005 10:00:00 9.1 0.7 11.1 6.8 9 0.8 10.7 7.2 0.4 0 0.4 0.4 25 4 25 305 13 0 13 0 -12.6 0 -12.5 -12.7 04/10/2005 10:10:00 8.5 0.7 10.3 6.5 8.5 0.7 9.9 6.5 0.4 0 0.4 0.4 25 5 31 305 14 0 13 0 -12.5 0 -12.3 -12.5 04/10/2005 10:20:00 9.1 0.6 10.7 7.6 9 0.6 10.7 7.2 0.4 0 0.4 0.4 19 4 14 305 14 0 14 0 -12.3 0 -11.7 -12.5 04/10/2005 10:30:00 9 0.6 10.3 7.2 8.9 0.5 10.3 7.2 0.4 0 0.4 0.4 21 5 17 305 14 0 14 0 -12.1 0.1 -11.7 -12.3 04/10/2005 10:40:00 9 0.6 10.3 7.6 9 0.7 10.3 7.2 0.4 0 0.4 0.4 25 4 16 305 14 0 14 0 -12 0 -11.7 -12.1 04/10/2005 10:50:00 9.6 0.6 11.1 8 9.5 0.7 11.5 7.6 0.4 0 0.4 0.4 25 4 26 305 15 0 15 0 -11.9 0.1 -11.5 -12.1 04/10/2005 11:00:00 8.9 0.8 10.7 6.8 8.8 0.8 10.7 6.5 0.4 0 0.4 0.4 23 4 23 305 16 0 15 0 -11.8 0.1 -11.5 -12.1 04/10/2005 11:10:00 9.2 1.1 11.5 6.8 9.2 1 11.1 6.8 0.4 0 0.4 0.4 22 4 16 305 16 0 16 0 -11.7 0.1 -11.3 -11.9 04/10/2005 11:20:00 9.4 0.7 10.7 7.2 9.3 0.8 11.1 6.8 0.4 0 0.4 0.4 19 4 17 305 17 0 16 0 -11.6 0.1 -11.3 -11.9 04/10/2005 11:30:00 8.8 0.9 11.1 6.5 8.8 0.9 10.7 6.8 0.4 0 0.4 0.4 22 4 21 305 17 0 17 0 -11.5 0.1 -11.1 -11.7 04/10/2005 11:40:00 8 0.6 9.9 6.5 7.9 0.7 9.9 6.1 0.4 0 0.4 0.4 21 5 17 305 18 0 18 0 -11.4 0.1 -10.9 -11.5 04/10/2005 11:50:00 8.5 0.6 9.9 6.5 8.4 0.7 9.9 5.7 0.4 0 0.4 0.4 24 5 30 305 18 0 18 0 -11.5 0 -11.1 -11.7 04/10/2005 12:00:00 7.9 0.6 9.5 6.1 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 18 4 15 305 18 0 18 0 -11.6 0 -11.3 -11.7 04/10/2005 12:10:00 7.9 0.5 9.1 6.5 7.8 0.6 8.8 6.1 0.4 0 0.4 0.4 21 3 17 305 19 0 19 0 -11.5 0 -11.3 -11.7 04/10/2005 12:20:00 7.9 0.6 9.1 6.1 7.8 0.6 9.1 6.5 0.4 0 0.4 0.4 23 3 22 305 19 0 19 0 -11.5 0 -11.3 -11.7 04/10/2005 12:30:00 6.9 0.6 8.4 5.7 6.9 0.6 8 5.7 0.4 0 0.4 0.4 16 4 12 305 20 0 20 0 -11.4 0.1 -10.9 -11.7 04/10/2005 12:40:00 7.3 0.6 8.8 5.7 7.2 0.7 8.4 5.7 0.4 0 0.4 0.4 19 4 18 305 20 0 20 0 -11.3 0 -10.9 -11.5 04/10/2005 12:50:00 7 0.6 8.4 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 22 4 18 305 21 0 20 0 -11.2 0 -10.9 -11.5 04/10/2005 13:00:00 6.5 0.6 8 4.6 6.5 0.7 8.4 4.6 0.4 0 0.4 0.4 21 6 23 305 21 0 21 0 -11 0.1 -10.9 -11.3 04/10/2005 13:10:00 7.1 0.5 8 5.7 7 0.5 8.4 5.7 0.4 0 0.4 0.4 22 4 24 305 22 0 22 0 -11.1 0 -10.9 -11.3 04/10/2005 13:20:00 7.2 0.5 8.4 5.7 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 21 4 18 305 23 0 22 0 -11 0 -10.9 -11.3 04/10/2005 13:30:00 7.2 0.6 8.4 5.7 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 23 4 26 305 23 0 23 0 -10.9 0 -10.7 -11.3 04/10/2005 13:40:00 7.3 0.7 8.4 5.7 7.3 0.7 8.4 5.7 0.4 0 0.4 0.4 22 4 18 305 23 0 24 0 -10.9 0 -10.7 -11.1 04/10/2005 13:50:00 7.1 0.6 8.4 5.3 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 24 5 22 305 24 0 24 0 -10.9 0 -10.7 -11.1 04/10/2005 14:00:00 6.9 0.5 8 5.3 6.8 0.6 8 5.3 0.4 0 0.4 0.4 21 6 17 305 24 0 24 0 -10.9 0 -10.7 -11.1 04/10/2005 14:10:00 6.9 0.6 8 5.3 6.9 0.6 8 5.3 0.4 0 0.4 0.4 19 5 19 305 25 0 25 0 -10.8 0 -10.4 -10.9 04/10/2005 14:20:00 7.2 0.6 8.8 5.7 7.2 0.6 8.4 5.3 0.4 0 0.4 0.4 22 5 24 305 25 0 25 0 -10.7 0 -10.4 -10.9 04/10/2005 14:30:00 7.4 0.4 8.4 6.1 7.4 0.5 8.4 5.7 0.4 0 0.4 0.4 21 3 20 305 25 0 25 0 -10.8 0 -10.4 -10.9 04/10/2005 14:40:00 7.1 0.6 8.4 5.7 7 0.6 8.8 5.3 0.4 0 0.4 0.4 23 4 23 305 26 0 26 0 -10.5 0 -10.4 -10.9 04/10/2005 14:50:00 7.2 0.6 8.8 5.7 7.1 0.6 8.4 5.3 0.4 0 0.4 0.4 24 5 26 305 26 0 26 0 -10.6 0 -10.4 -10.9 04/10/2005 15:00:00 6.7 0.5 8 5.3 6.6 0.5 8 5.3 0.4 0 0.4 0.4 22 5 29 305 27 0 26 0 -10.5 0 -10.2 -10.9 04/10/2005 15:10:00 6.6 0.5 8 4.9 6.6 0.6 8 4.9 0.4 0 0.4 0.4 24 5 21 305 28 0 27 0 -10.5 0 -10.2 -10.7 04/10/2005 15:20:00 6.8 0.4 8 5.3 6.7 0.5 8 5.3 0.4 0 0.4 0.4 24 4 26 305 29 0 28 0 -10.4 0 -10 -10.7 04/10/2005 15:30:00 6.5 0.6 8 4.9 6.5 0.6 7.6 4.6 0.4 0 0.4 0.4 16 5 13 305 30 0 29 0 -10.3 0.1 -9.8 -10.4 04/10/2005 15:40:00 6.4 0.5 7.2 4.9 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 14 4 12 305 31 0 30 0 -10.3 0.1 -9.8 -10.4 04/10/2005 15:50:00 6.1 0.5 7.6 4.6 6 0.5 7.2 4.6 0.4 0 0.4 0.4 15 5 10 305 31 0 31 0 -10.2 0.1 -9.8 -10.4 04/10/2005 16:00:00 6.1 0.5 7.2 4.6 6.1 0.5 7.2 4.9 0.4 0 0.4 0.4 13 4 9 305 32 0 32 0 -10.2 0.1 -9.8 -10.4 04/10/2005 16:10:00 6.2 0.5 7.2 4.9 6.1 0.6 7.2 4.6 0.4 0 0.4 0.4 11 4 12 305 33 0 33 0 -10.1 0 -9.6 -10.4 04/10/2005 16:20:00 6.3 0.6 7.6 4.6 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 14 4 13 305 34 0 34 0 -10.1 0 -9.8 -10.4 04/10/2005 16:30:00 6 0.6 7.2 4.2 6 0.5 7.2 4.2 0.4 0 0.4 0.4 13 5 22 305 35 0 36 0 -10 0.1 -9.6 -10.2 04/10/2005 16:40:00 6.1 0.6 7.2 4.9 6 0.6 7.2 4.2 0.4 0 0.4 0.4 8 5 7 305 36 0 36 0 -9.9 0 -9.6 -10 04/10/2005 16:50:00 6.1 0.6 7.2 3.8 6 0.6 7.6 4.6 0.4 0 0.4 0.4 13 4 8 305 37 0 36 0 -9.9 0 -9.6 -10 04/10/2005 17:00:00 5.8 0.5 6.8 4.6 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 14 5 12 305 38 0 37 0 -9.9 0 -9.6 -10 04/10/2005 17:10:00 5.4 0.5 6.5 4.2 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 17 6 27 305 39 0 39 0 -9.7 0.1 -9.4 -10 04/10/2005 17:20:00 6.2 0.4 7.2 5.3 6.3 0.4 7.2 4.9 0.4 0 0.4 0.4 21 4 22 305 39 0 40 0 -9.9 0 -9.6 -10 04/10/2005 17:30:00 6.5 0.5 7.2 4.9 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 24 6 21 305 40 0 40 0 -9.9 0 -9.6 -10.2 04/10/2005 17:40:00 6.2 0.6 7.6 4.9 6.2 0.6 7.2 4.6 0.4 0 0.4 0.4 28 6 27 305 41 0 40 0 -10 0 -9.8 -10.2 04/10/2005 17:50:00 6.4 0.4 7.6 5.3 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 29 6 33 305 41 0 41 0 -10 0 -9.8 -10.2 04/10/2005 18:00:00 6.4 0.5 7.6 5.3 6.4 0.6 7.6 4.9 0.4 0 0.4 0.4 31 6 26 305 41 0 41 0 -10.1 0 -9.8 -10.2 04/10/2005 18:10:00 6.2 0.5 7.6 4.9 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 32 6 34 305 42 0 41 0 -10 0 -9.8 -10.2 04/10/2005 18:20:00 6.1 0.5 7.2 4.9 6 0.6 7.2 4.6 0.4 0 0.4 0.4 38 5 42 305 41 0 41 0 -10.1 0 -10 -10.4 04/10/2005 18:30:00 6.2 0.5 7.2 4.9 6.2 0.5 7.2 4.6 0.4 0 0.4 0.4 33 5 36 305 41 0 41 0 -10.2 0 -10 -10.4 04/10/2005 18:40:00 5.9 0.5 6.8 4.6 5.9 0.5 6.8 4.2 0.4 0 0.4 0.4 33 5 28 305 42 0 41 0 -10.2 0 -10 -10.4 04/10/2005 18:50:00 5.7 0.4 6.5 4.2 5.6 0.5 6.5 4.2 0.4 0 0.4 0.4 28 4 40 305 42 0 42 0 -10.3 0 -10 -10.4 04/10/2005 19:00:00 6.1 0.5 7.2 4.6 6 0.6 7.2 4.6 0.4 0 0.4 0.4 29 4 36 305 42 0 42 0 -10.4 0 -10.2 -10.7 04/10/2005 19:10:00 5.7 0.5 6.8 4.6 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 29 6 24 305 42 0 42 0 -10.4 0 -10.4 -10.7 04/10/2005 19:20:00 6 0.4 6.8 4.9 5.9 0.4 6.8 4.9 0.4 0 0.4 0.4 27 3 28 305 42 0 42 0 -10.5 0 -10.4 -10.7 04/10/2005 19:30:00 6 0.3 6.5 4.9 5.8 0.4 6.8 4.9 0.4 0 0.4 0.4 27 5 30 305 42 0 42 0 -10.4 0 -10.2 -10.7 04/10/2005 19:40:00 5.8 0.3 6.5 4.6 5.7 0.4 6.5 4.9 0.4 0 0.4 0.4 26 3 25 305 42 0 42 0 -10.6 0 -10.4 -10.9 04/10/2005 19:50:00 5.7 0.4 6.5 4.6 5.6 0.5 6.5 4.2 0.4 0 0.4 0.4 25 5 29 305 42 0 42 0 -10.7 0 -10.4 -10.9 04/10/2005 20:00:00 5.6 0.4 6.5 4.6 5.5 0.4 6.5 4.6 0.4 0 0.4 0.4 24 3 31 305 42 0 42 0 -10.9 0 -10.7 -10.9 04/10/2005 20:10:00 5.4 0.4 6.5 4.2 5.2 0.4 6.1 4.2 0.4 0 0.4 0.4 23 5 20 305 41 0 41 0 -10.9 0 -10.9 -11.1 04/10/2005 20:20:00 5.4 0.4 6.5 4.6 5.3 0.4 6.5 4.2 0.4 0 0.4 0.4 25 4 26 305 40 0 40 0 -10.9 0 -10.7 -11.1 04/10/2005 20:30:00 5.4 0.4 6.5 4.6 5.3 0.5 6.5 3.8 0.4 0 0.4 0.4 24 3 22 305 40 0 40 0 -11.1 0 -10.9 -11.3 04/10/2005 20:40:00 6 0.5 6.8 4.6 5.9 0.5 6.8 4.6 0.4 0 0.4 0.4 27 4 29 305 39 0 39 0 -11.2 0 -10.9 -11.5 04/10/2005 20:50:00 5.5 0.5 6.5 4.2 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 25 3 24 305 38 0 39 0 -11.3 0 -11.1 -11.5 04/10/2005 21:00:00 5.7 0.4 6.5 4.6 5.6 0.5 6.5 4.2 0.4 0 0.4 0.4 26 3 25 305 37 0 37 0 -11.4 0 -11.3 -11.5 04/10/2005 21:10:00 6 0.5 6.8 4.9 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 27 5 22 305 36 0 36 0 -11.5 0 -11.3 -11.7 04/10/2005 21:20:00 6.1 0.5 7.2 4.9 6 0.5 6.8 4.6 0.4 0 0.4 0.4 33 4 35 305 34 0 35 0 -11.6 0 -11.3 -11.9 04/10/2005 21:30:00 6.3 0.4 7.2 5.3 6.3 0.4 7.2 5.3 0.4 0 0.4 0.4 38 4 42 305 33 0 33 0 -11.8 0 -11.5 -12.1 04/10/2005 21:40:00 6.1 0.5 7.2 4.9 6 0.5 7.2 4.6 0.4 0 0.4 0.4 37 4 30 305 31 0 32 0 -11.9 0.1 -11.7 -12.1 04/10/2005 21:50:00 5.5 0.4 6.5 4.2 5.3 0.4 6.5 3.8 0.4 0 0.4 0.4 31 4 37 305 30 0 31 0 -12 0 -11.7 -12.1 04/10/2005 22:00:00 4.9 0.4 5.7 3.8 4.7 0.4 5.7 3.8 0.4 0 0.4 0.4 32 3 35 305 29 0 29 0 -12 0 -11.9 -12.3 04/10/2005 22:10:00 4.4 0.4 5.7 3.8 4.3 0.4 5.3 3.4 0.4 0 0.4 0.4 34 4 35 305 28 0 28 0 -12.1 0 -12.1 -12.5 04/10/2005 22:20:00 4.5 0.4 5.3 3.4 4.3 0.5 5.3 3 0.4 0 0.4 0.4 41 6 48 305 27 0 26 0 -12.2 0 -12.1 -12.5 04/10/2005 22:30:00 4.6 0.3 5.3 3.8 4.5 0.3 5.3 3.8 0.4 0 0.4 0.4 48 3 48 305 26 0 26 0 -12.3 0 -12.1 -12.5 04/10/2005 22:40:00 4.8 0.3 5.7 4.2 4.6 0.4 5.7 3.8 0.4 0 0.4 0.4 45 4 42 305 25 0 25 0 -12.4 0 -12.1 -12.5 04/10/2005 22:50:00 4.8 0.4 5.7 4.2 4.7 0.4 5.7 3.8 0.4 0 0.4 0.4 41 4 46 305 24 0 24 0 -12.4 0 -12.1 -12.5 04/10/2005 23:00:00 4.7 0.3 5.3 4.2 4.6 0.4 5.3 3.8 0.4 0 0.4 0.4 41 3 41 305 24 0 24 0 -12.3 0 -12.1 -12.5 04/10/2005 23:10:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.8 0.4 0 0.4 0.4 39 3 35 305 23 0 22 0 -12.5 0 -12.3 -12.5 04/10/2005 23:20:00 4.7 0.2 5.3 4.2 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 38 2 36 305 22 0 22 0 -12.6 0 -12.3 -12.7 04/10/2005 23:30:00 4.6 0.3 5.3 3.8 4.5 0.3 5.3 3.8 0.4 0 0.4 0.4 41 3 38 305 22 0 22 0 -12.7 0.1 -12.5 -13.1 04/10/2005 23:40:00 4.3 0.2 4.9 3.8 4.1 0.2 4.6 3.8 0.4 0 0.4 0.4 45 3 42 305 21 0 21 0 -12.8 0 -12.5 -12.9 04/10/2005 23:50:00 4.7 0.3 5.3 3.8 4.5 0.3 4.9 3.8 0.4 0 0.4 0.4 48 3 48 305 20 0 21 0 -12.8 0.1 -12.5 -13.1 04/11/2005 00:00:00 4.8 0.2 5.3 4.2 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 48 3 51 305 20 0 20 0 -12.8 0 -12.5 -12.9 04/11/2005 00:10:00 4.7 0.2 5.3 4.2 4.5 0.3 5.3 3.8 0.4 0 0.4 0.4 44 3 45 305 19 0 19 0 -12.9 0 -12.7 -13.1 04/11/2005 00:20:00 5 0.5 6.1 3.8 4.9 0.6 6.1 3.8 0.4 0 0.4 0.4 44 3 39 305 19 0 19 0 -12.9 0 -12.5 -13.1 04/11/2005 00:30:00 5 0.3 5.7 4.2 5 0.3 5.7 4.6 0.4 0 0.4 0.4 43 3 41 305 18 0 19 0 -12.8 0 -12.5 -13.1 04/11/2005 00:40:00 5.1 0.3 5.7 4.6 5.1 0.3 5.7 4.2 0.4 0 0.4 0.4 42 3 47 305 18 0 18 0 -13 0 -12.9 -13.1 04/11/2005 00:50:00 5.1 0.4 6.1 4.2 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 42 3 43 305 18 0 18 0 -12.9 0 -12.5 -13.1 04/11/2005 01:00:00 4.9 0.3 5.7 4.2 4.8 0.4 5.7 4.2 0.4 0 0.4 0.4 42 3 40 305 18 0 18 0 -13 0 -12.7 -13.1 04/11/2005 01:10:00 4.4 0.4 5.3 3.4 4.2 0.5 5.3 3 0.4 0 0.4 0.4 43 3 39 305 17 0 18 0 -12.9 0.1 -12.7 -13.1 04/11/2005 01:20:00 4 0.3 4.9 3 3.7 0.4 4.6 2.6 0.4 0 0.4 0.4 47 3 49 305 17 0 17 0 -13 0.1 -12.7 -13.1 04/11/2005 01:30:00 4.1 0.3 4.9 3.4 3.8 0.3 4.6 3.4 0.4 0 0.4 0.4 53 2 51 305 17 0 17 0 -13.1 0 -12.9 -13.3 04/11/2005 01:40:00 3.8 0.3 4.6 3.4 3.6 0.3 4.2 2.6 0.4 0 0.4 0.4 53 2 56 305 17 0 17 0 -13.4 0 -13.1 -13.5 04/11/2005 01:50:00 3.7 0.2 4.2 3.4 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 51 3 52 305 16 0 16 0 -13.3 0 -13.1 -13.5 04/11/2005 02:00:00 3.8 0.2 4.2 3.4 3.6 0.2 4.2 3 0.4 0 0.4 0.4 52 2 46 305 16 0 16 0 -13.1 0 -12.9 -13.3 04/11/2005 02:10:00 3.9 0.2 4.6 3.4 3.7 0.3 4.6 3 0.4 0 0.4 0.4 55 3 56 305 16 0 16 0 -13 0 -12.7 -13.3 04/11/2005 02:20:00 3.2 0.6 4.2 1.9 3 0.5 4.2 1.9 0.4 0 0.4 0.4 61 7 61 305 16 0 16 0 -13 0 -12.7 -13.3 04/11/2005 02:30:00 2.7 0.6 4.2 1.1 2.4 0.6 4.2 1.1 0.4 0 0.4 0.4 93 15 104 305 16 0 16 0 -13.4 0.2 -12.9 -13.7 04/11/2005 02:40:00 4.4 0.8 5.7 2.3 3.7 1 5.3 0.7 0.4 0 0.4 0.4 103 8 101 305 16 0 16 0 -13.6 0.1 -13.3 -13.9 04/11/2005 02:50:00 4.6 0.7 6.5 2.6 4.2 0.9 6.5 1.5 0.4 0 0.4 0.4 106 8 93 305 16 0 15 0 -13.8 0 -13.5 -14.1 04/11/2005 03:00:00 4.9 0.8 6.8 2.6 5 0.7 6.8 3 0.4 0 0.4 0.4 105 11 110 305 16 0 15 0 -13.3 0.2 -12.9 -13.7 04/11/2005 03:10:00 3.9 1.1 7.2 1.1 3.9 1.1 6.8 0.4 0.4 0 0.4 0.4 92 17 103 305 16 0 16 0 -12.9 0.1 -12.5 -13.1 04/11/2005 03:20:00 3.5 1 5.7 1.1 3.3 0.9 5.3 1.1 0.4 0 0.4 0.4 89 18 113 305 16 0 16 0 -12.6 0 -12.3 -12.9 04/11/2005 03:30:00 3.5 0.8 5.7 1.1 3.4 0.8 5.7 1.1 0.4 0 0.4 0.4 88 17 93 305 16 0 16 0 -12.7 0 -12.5 -12.9 04/11/2005 03:40:00 3.7 1.4 6.1 0.4 3.8 1.2 6.5 0.7 0.4 0 0.4 0.4 96 19 114 305 16 0 16 0 -12.6 0.1 -12.3 -12.9 04/11/2005 03:50:00 3.8 0.8 6.1 1.9 3.8 0.9 6.1 1.1 0.4 0 0.4 0.4 95 14 103 305 16 0 16 0 -12.7 0 -12.5 -12.9 04/11/2005 04:00:00 5.6 1.2 7.6 1.9 5.8 0.9 7.6 3 0.4 0 0.4 0.4 104 10 103 305 16 0 16 0 -12.9 0.2 -12.5 -13.3 04/11/2005 04:10:00 6.7 0.7 8 4.2 6.6 0.6 8 4.6 0.4 0 0.4 0.4 103 6 105 305 16 0 16 0 -13.4 0 -13.1 -13.5 04/11/2005 04:20:00 6.7 0.8 8 3.8 7.1 0.6 8.4 4.6 0.4 0 0.4 0.4 106 7 109 305 16 0 16 0 -13.3 0 -12.9 -13.5 04/11/2005 04:30:00 6.7 1 8.4 3.8 7.3 0.8 8.8 4.6 0.4 0 0.4 0.4 111 6 107 305 16 0 16 0 -13.2 0 -12.9 -13.3 04/11/2005 04:40:00 6.1 1 8 3 6.7 0.9 8.8 3.8 0.4 0 0.4 0.4 112 9 110 305 16 0 16 0 -13 0 -12.7 -13.3 04/11/2005 04:50:00 4.4 1.2 7.2 1.9 4.7 1.4 7.6 0.7 0.4 0 0.4 0.4 107 18 118 305 16 0 16 0 -13.1 0 -12.7 -13.3 04/11/2005 05:00:00 4.6 1.3 8 1.5 4.4 1.3 7.6 1.5 0.4 0 0.4 0.4 111 15 106 305 16 0 16 0 -12.9 0.1 -12.5 -13.1 04/11/2005 05:10:00 5.8 1.3 8 1.9 5.6 1.3 8 0.7 0.4 0 0.4 0.4 108 10 112 305 16 0 16 0 -13.2 0 -12.7 -13.3 04/11/2005 05:20:00 6.5 0.7 8.4 3.8 6.5 0.8 8.8 3.8 0.4 0 0.4 0.4 109 6 108 305 16 0 16 0 -13.3 0 -12.9 -13.5 04/11/2005 05:30:00 6 0.6 7.6 4.2 5.9 0.6 8.4 4.2 0.4 0 0.4 0.4 114 7 114 305 16 0 16 0 -13.3 0 -12.9 -13.5 04/11/2005 05:40:00 5.5 0.7 6.8 3 5.1 1 6.5 1.9 0.4 0 0.4 0.4 109 8 107 305 16 0 16 0 -13.2 0.1 -12.9 -13.7 04/11/2005 05:50:00 4.4 0.5 5.7 3 3.7 0.6 4.9 2.3 0.4 0 0.4 0.4 90 8 108 305 16 0 16 0 -13.5 0.1 -12.9 -13.7 04/11/2005 06:00:00 4.7 0.5 5.7 3.4 4.2 0.5 5.3 2.6 0.4 0 0.4 0.4 94 5 90 305 15 0 15 0 -13.5 0.1 -13.1 -13.7 04/11/2005 06:10:00 5.2 0.3 6.1 4.6 4.6 0.4 5.7 3.4 0.4 0 0.4 0.4 89 4 95 305 15 0 15 0 -13.7 0 -13.3 -13.7 04/11/2005 06:20:00 5.6 0.4 6.5 4.2 5.1 0.4 6.1 3.8 0.4 0 0.4 0.4 91 5 89 305 15 0 15 0 -13.8 0 -13.5 -13.9 04/11/2005 06:30:00 5.3 0.6 6.8 3.8 5 0.6 6.5 3.4 0.4 0 0.4 0.4 92 6 98 305 15 0 15 0 -13.9 0 -13.7 -14.1 04/11/2005 06:40:00 4.8 0.6 6.1 3.4 4.2 0.5 5.3 2.3 0.4 0 0.4 0.4 85 9 95 305 15 0 15 0 -13.9 0 -13.7 -14.3 04/11/2005 06:50:00 3.9 1 6.1 1.9 3.7 0.9 5.3 1.5 0.4 0 0.4 0.4 61 15 88 305 15 0 15 0 -13.7 0 -13.3 -13.7 04/11/2005 07:00:00 2.9 0.8 4.9 0.7 2.8 0.8 4.6 0.7 0.4 0 0.4 0.4 51 13 52 305 15 0 14 0 -13.5 0.1 -13.1 -13.7 04/11/2005 07:10:00 1.4 0.8 3.4 0.4 1.3 0.8 3.4 0.4 0.4 0 0.4 0.4 33 28 52 305 15 0 14 0 -13.3 0 -13.1 -13.5 04/11/2005 07:20:00 2.7 1.2 5.7 0.4 2.5 1.1 5.7 0.4 0.4 0 0.4 0.4 65 24 96 305 15 0 15 0 -13.2 0 -12.9 -13.3 04/11/2005 07:30:00 3.3 0.6 4.9 1.1 3.1 0.6 4.6 1.5 0.4 0 0.4 0.4 54 17 40 305 15 0 15 0 -13.3 0.1 -12.9 -13.5 04/11/2005 07:40:00 3.7 0.9 6.1 1.5 3.5 0.8 5.3 1.5 0.4 0 0.4 0.4 61 18 83 305 15 0 14 0 -13.4 0.1 -12.9 -13.5 04/11/2005 07:50:00 3.1 0.5 4.6 1.5 2.9 0.6 4.2 1.1 0.4 0 0.4 0.4 61 9 57 305 15 0 15 0 -13.5 0.1 -12.9 -13.7 04/11/2005 08:00:00 3.6 0.6 5.3 2.3 3.2 0.6 4.9 1.5 0.4 0 0.4 0.4 62 11 64 305 15 0 15 0 -13.4 0 -13.1 -13.7 04/11/2005 08:10:00 3.7 0.6 5.7 1.5 3.5 0.5 4.9 1.9 0.4 0 0.4 0.4 67 13 72 305 15 0 15 0 -13.4 0.1 -12.9 -13.7 04/11/2005 08:20:00 3.7 0.7 4.9 1.5 3.7 0.6 5.7 2.3 0.4 0 0.4 0.4 59 17 65 305 15 0 15 0 -13.6 0 -13.3 -13.7 04/11/2005 08:30:00 3.4 0.8 6.8 1.5 3.5 1 6.5 1.5 0.4 0 0.4 0.4 29 29 7 305 15 0 15 0 -13.2 0.2 -12.5 -13.7 04/11/2005 08:40:00 2.7 0.7 4.6 1.1 2.9 0.7 4.9 1.5 0.4 0 0.4 0.4 50 26 90 305 16 0 15 0 -13.2 0.1 -12.7 -13.5 04/11/2005 08:50:00 3.2 0.9 5.7 1.1 2.6 0.7 4.9 0.7 0.4 0 0.4 0.4 73 27 95 305 17 0 17 0 -13.4 0.1 -12.9 -13.5 04/11/2005 09:00:00 4.9 1 7.2 2.3 3.9 0.9 6.5 1.1 0.4 0 0.4 0.4 94 11 90 305 17 0 18 0 -13.3 0.1 -12.9 -13.5 04/11/2005 09:10:00 6.1 0.8 7.6 4.2 5.2 0.8 7.2 3 0.4 0 0.4 0.4 96 7 99 305 18 0 18 0 -13.2 0.2 -12.5 -13.5 04/11/2005 09:20:00 7.1 0.5 8.4 5.3 6.2 0.7 7.6 3.4 0.4 0 0.4 0.4 100 4 98 305 18 0 18 0 -12.8 0 -12.3 -13.1 04/11/2005 09:30:00 7.6 0.7 9.1 5.3 6.8 0.7 8.4 4.6 0.4 0 0.4 0.4 100 4 95 305 18 0 18 0 -12.6 0.1 -12.1 -12.9 04/11/2005 09:40:00 7.3 0.6 8.8 4.9 6.3 0.9 8 3 0.4 0 0.4 0.4 103 6 100 305 18 0 18 0 -12.4 0.2 -11.7 -12.9 04/11/2005 09:50:00 6.5 1 8.4 3.4 5.9 1 8 2.3 0.4 0 0.4 0.4 109 8 95 305 18 0 18 0 -11.7 0.2 -11.1 -12.3 04/11/2005 10:00:00 5.7 1.1 7.6 2.3 5.3 1.3 8 1.1 0.4 0 0.4 0.4 113 10 98 305 19 0 19 0 -11 0.1 -10.4 -11.5 04/11/2005 10:10:00 6.5 1.3 8.8 2.6 6.4 1.3 9.1 1.9 0.4 0 0.4 0.4 118 11 115 305 20 0 20 0 -11.2 0.1 -10.7 -11.7 04/11/2005 10:20:00 6.7 1.4 10.7 2.6 6.6 1.4 9.9 3.4 0.4 0 0.4 0.4 115 11 105 305 20 0 20 0 -11.5 0 -10.9 -11.7 04/11/2005 10:30:00 7.4 1.3 9.9 2.6 7.3 1.4 9.9 2.6 0.4 0 0.4 0.4 115 8 116 305 20 0 20 0 -11.7 0.1 -11.3 -12.1 04/11/2005 10:40:00 8.1 1.1 10.7 4.6 7.9 1.3 9.9 4.6 0.4 0 0.4 0.4 115 9 146 305 19 0 19 0 -11.6 0 -11.3 -11.9 04/11/2005 10:50:00 8.8 0.9 10.3 5.7 8.6 1 11.1 5.3 0.4 0 0.4 0.4 113 6 116 305 19 0 19 0 -11.6 0 -11.3 -11.9 04/11/2005 11:00:00 8.8 1.1 11.8 4.9 8.7 1.2 11.8 4.9 0.4 0 0.4 0.4 116 6 121 305 19 0 19 0 -11.4 0 -10.9 -11.7 04/11/2005 11:10:00 9.7 0.8 11.5 6.5 9.5 0.9 11.1 6.5 0.4 0 0.4 0.4 115 3 112 305 19 0 19 0 -11.6 0 -11.3 -11.9 04/11/2005 11:20:00 9.2 0.8 11.8 6.8 9 0.8 11.5 6.5 0.4 0 0.4 0.4 114 3 113 305 19 0 19 0 -11.6 0 -11.3 -11.7 04/11/2005 11:30:00 9.1 0.5 10.3 7.6 8.9 0.6 10.3 7.2 0.4 0 0.4 0.4 113 2 116 305 19 0 19 0 -11.4 0.1 -11.1 -11.7 04/11/2005 11:40:00 9.3 0.4 10.3 8 9 0.4 9.9 7.6 0.4 0 0.4 0.4 112 2 113 305 19 0 19 0 -11.3 0.2 -10.9 -11.5 04/11/2005 11:50:00 9.9 0.6 11.1 8 9.5 0.6 10.7 7.6 0.4 0 0.4 0.4 111 2 109 305 19 0 19 0 -11.3 0.2 -10.7 -11.5 04/11/2005 12:00:00 9.8 0.5 11.1 8.4 9.3 0.5 10.3 7.6 0.4 0 0.4 0.4 108 3 107 305 19 0 19 0 -11.4 0 -11.1 -11.7 04/11/2005 12:10:00 10.3 0.8 11.8 8.4 9.7 0.8 11.5 7.2 0.4 0 0.4 0.4 107 3 105 305 19 0 19 0 -11.1 0.1 -10.9 -11.5 04/11/2005 12:20:00 11 0.3 11.8 9.9 10.2 0.4 11.1 9.1 0.4 0 0.4 0.4 103 2 103 305 19 0 19 0 -11.1 0.1 -10.7 -11.5 04/11/2005 12:30:00 11.1 0.5 12.6 9.5 10.2 0.6 11.5 8.4 0.4 0 0.4 0.4 103 2 102 305 19 0 19 0 -10.9 0.1 -10.4 -11.3 04/11/2005 12:40:00 11.5 0.7 13 9.5 10.4 0.7 11.8 8.4 0.4 0 0.4 0.4 102 2 102 305 19 0 19 0 -10.7 0.1 -10.4 -10.9 04/11/2005 12:50:00 11.3 0.7 12.6 9.1 10.2 0.7 11.8 8.4 0.4 0 0.4 0.4 101 3 101 305 20 0 19 0 -10.8 0.1 -10.4 -10.9 04/11/2005 13:00:00 11.6 0.8 13.3 9.1 10.7 0.8 13 8.8 0.4 0 0.4 0.4 104 3 103 305 20 0 20 0 -10.4 0.2 -9.8 -10.9 04/11/2005 13:10:00 11.6 0.7 13 9.1 10.7 0.7 12.2 8.8 0.4 0 0.4 0.4 104 3 103 305 20 0 20 0 -10.1 0.1 -9.8 -10.4 04/11/2005 13:20:00 11.2 0.7 13 9.5 10.2 0.6 11.8 8.4 0.4 0 0.4 0.4 100 3 102 305 20 0 20 0 -10.2 0.1 -9.8 -10.4 04/11/2005 13:30:00 10.2 0.8 11.8 8.4 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 105 4 98 305 20 0 20 0 -10.3 0.1 -9.8 -10.7 04/11/2005 13:40:00 9.5 0.7 11.1 7.6 9 0.7 11.1 7.2 0.4 0 0.4 0.4 108 5 112 305 20 0 20 0 -10.2 0.1 -9.8 -10.4 04/11/2005 13:50:00 9.6 1 12.2 7.2 9.2 1 11.5 6.8 0.4 0 0.4 0.4 110 5 108 305 20 0 20 0 -10.3 0.2 -9.8 -10.7 04/11/2005 14:00:00 10.5 0.7 12.6 8.8 10 0.6 11.8 8 0.4 0 0.4 0.4 109 4 106 305 20 0 20 0 -10.7 0 -10.4 -10.9 04/11/2005 14:10:00 10.8 0.7 12.2 8.8 10.1 0.6 11.5 8.4 0.4 0 0.4 0.4 107 4 103 305 20 0 20 0 -10.5 0.1 -10 -10.9 04/11/2005 14:20:00 10.4 0.8 12.2 8.4 9.8 0.7 11.1 7.6 0.4 0 0.4 0.4 108 5 113 305 20 0 20 0 -10.3 0 -10 -10.4 04/11/2005 14:30:00 10.2 0.9 12.2 7.6 9.8 0.9 11.8 7.2 0.4 0 0.4 0.4 110 5 113 305 20 0 20 0 -10.4 0 -10 -10.4 04/11/2005 14:40:00 10.6 0.7 11.8 8 10.1 0.6 11.5 8 0.4 0 0.4 0.4 110 4 109 305 20 0 20 0 -10.2 0.1 -9.8 -10.4 04/11/2005 14:50:00 9.9 0.6 11.5 8.4 9.5 0.6 11.1 7.6 0.4 0 0.4 0.4 110 4 110 305 20 0 20 0 -9.6 0.2 -9.2 -10 04/11/2005 15:00:00 9.7 0.6 10.7 8.4 9.3 0.6 10.7 7.2 0.4 0 0.4 0.4 108 3 106 305 21 0 20 0 -9.4 0.2 -8.8 -9.6 04/11/2005 15:10:00 9 0.8 10.7 6.8 8.7 0.8 10.3 6.1 0.4 0 0.4 0.4 109 4 109 305 21 0 21 0 -9.3 0 -8.8 -9.4 04/11/2005 15:20:00 9.4 0.4 10.3 8 9.1 0.4 9.9 7.6 0.4 0 0.4 0.4 113 3 112 305 21 0 21 0 -9.6 0.1 -9.2 -9.8 04/11/2005 15:30:00 8.5 0.6 10.3 6.8 8.4 0.7 9.9 6.8 0.4 0 0.4 0.4 116 3 113 305 21 0 21 0 -9.4 0.2 -8.8 -9.8 04/11/2005 15:40:00 8.7 0.7 10.3 6.8 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 115 3 113 305 21 0 21 0 -9.3 0 -8.8 -9.4 04/11/2005 15:50:00 8.8 0.5 9.9 7.6 8.7 0.4 9.5 7.6 0.4 0 0.4 0.4 119 3 118 305 22 0 21 0 -9.1 0.1 -8.8 -9.2 04/11/2005 16:00:00 8.9 0.4 9.9 8 8.8 0.4 9.9 7.6 0.4 0 0.4 0.4 120 3 123 305 22 0 22 0 -9.1 0.1 -8.8 -9.2 04/11/2005 16:10:00 9.3 0.4 9.9 8 9.2 0.4 10.3 8 0.4 0 0.4 0.4 117 2 113 305 22 0 22 0 -9.3 0 -8.8 -9.6 04/11/2005 16:20:00 9.3 0.6 10.3 7.6 9 0.7 10.3 6.5 0.4 0 0.4 0.4 114 3 114 305 22 0 22 0 -9.6 0.1 -9.2 -9.8 04/11/2005 16:30:00 8.8 0.5 9.9 7.2 8.7 0.5 9.9 7.2 0.4 0 0.4 0.4 120 2 117 305 22 0 22 0 -9.3 0.2 -8.8 -9.8 04/11/2005 16:40:00 8.8 0.4 9.9 7.6 8.6 0.4 9.5 7.2 0.4 0 0.4 0.4 118 3 118 305 22 0 22 0 -9.3 0 -8.8 -9.4 04/11/2005 16:50:00 8.6 0.5 9.9 7.2 8.5 0.5 9.9 7.2 0.4 0 0.4 0.4 118 2 119 305 22 0 22 0 -9.4 0 -9 -9.6 04/11/2005 17:00:00 8.8 0.5 9.9 7.6 8.7 0.5 9.5 7.2 0.4 0 0.4 0.4 118 2 118 305 22 0 22 0 -9.5 0 -9.2 -9.6 04/11/2005 17:10:00 9 0.4 9.9 7.6 9 0.4 9.9 7.6 0.4 0 0.4 0.4 117 2 119 305 22 0 22 0 -9.5 0 -9.2 -9.6 04/11/2005 17:20:00 8.9 0.5 9.9 7.2 8.8 0.5 9.9 7.2 0.4 0 0.4 0.4 116 3 116 305 22 0 22 0 -9.5 0 -9.2 -9.6 04/11/2005 17:30:00 9 0.5 9.9 7.2 8.9 0.6 10.3 7.6 0.4 0 0.4 0.4 115 3 113 305 22 0 22 0 -9.6 0.1 -9.2 -9.8 04/11/2005 17:40:00 8.6 0.5 9.5 7.2 8.2 0.5 9.1 6.5 0.4 0 0.4 0.4 112 3 113 305 22 0 22 0 -9.7 0 -9.2 -9.8 04/11/2005 17:50:00 8.1 0.5 9.1 6.5 7.8 0.5 9.1 6.5 0.4 0 0.4 0.4 111 2 112 305 22 0 22 0 -9.8 0 -9.4 -10 04/11/2005 18:00:00 7.6 0.5 9.1 6.1 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 111 3 109 305 22 0 22 0 -9.6 0.1 -9.2 -9.8 04/11/2005 18:10:00 8.1 0.5 9.5 6.8 7.7 0.5 9.1 6.1 0.4 0 0.4 0.4 110 3 108 305 22 0 22 0 -9.4 0 -9.2 -9.6 04/11/2005 18:20:00 8.7 0.5 9.9 7.6 8.2 0.5 9.1 6.8 0.4 0 0.4 0.4 108 2 108 305 22 0 22 0 -9.5 0 -9.2 -9.6 04/11/2005 18:30:00 9.6 0.4 10.3 8.4 8.9 0.4 9.9 8 0.4 0 0.4 0.4 107 2 109 305 22 0 22 0 -9.7 0.1 -9.2 -9.8 04/11/2005 18:40:00 9.7 0.5 10.7 8.4 9 0.4 9.9 8 0.4 0 0.4 0.4 107 3 105 305 22 0 22 0 -9.8 0 -9.4 -9.8 04/11/2005 18:50:00 9.2 0.5 10.3 8 8.8 0.4 9.9 7.6 0.4 0 0.4 0.4 109 3 110 305 22 0 22 0 -9.9 0 -9.4 -10 04/11/2005 19:00:00 9.4 0.4 10.3 8.4 8.9 0.4 9.9 8 0.4 0 0.4 0.4 109 3 110 305 22 0 22 0 -9.9 0 -9.6 -10 04/11/2005 19:10:00 9.4 0.5 10.7 8 8.8 0.4 9.9 7.6 0.4 0 0.4 0.4 107 3 108 305 22 0 22 0 -9.9 0 -9.6 -10 04/11/2005 19:20:00 9.1 0.7 10.3 7.2 8.2 0.7 9.9 6.5 0.4 0 0.4 0.4 99 5 101 305 22 0 22 0 -10.1 0 -9.6 -10.2 04/11/2005 19:30:00 7.4 0.6 9.1 5.7 6.7 0.6 8.4 4.9 0.4 0 0.4 0.4 87 5 82 305 22 0 22 0 -10.1 0 -9.8 -10.2 04/11/2005 19:40:00 7.1 0.7 8.4 4.9 6.3 0.6 8 4.2 0.4 0 0.4 0.4 85 5 84 305 22 0 22 0 -10.3 0 -9.8 -10.4 04/11/2005 19:50:00 6.3 0.6 8 4.9 5.6 0.6 7.2 4.2 0.4 0 0.4 0.4 83 6 85 305 22 0 22 0 -10.4 0 -10 -10.7 04/11/2005 20:00:00 6.1 0.8 8.8 4.2 5.4 0.8 7.6 3 0.4 0 0.4 0.4 80 8 86 305 22 0 22 0 -10.6 0.1 -10.2 -10.9 04/11/2005 20:10:00 6.2 0.7 7.6 3.8 5.5 0.7 6.8 3.4 0.4 0 0.4 0.4 84 8 82 305 22 0 22 0 -10.8 0.1 -10.4 -10.9 04/11/2005 20:20:00 6.6 0.7 8 4.2 5.8 0.7 8 3.4 0.4 0 0.4 0.4 84 9 84 305 22 0 22 0 -10.8 0.1 -10.4 -10.9 04/11/2005 20:30:00 6.5 0.8 8.4 3.8 5.8 0.8 7.6 3 0.4 0 0.4 0.4 74 9 75 305 22 0 21 0 -10.9 0 -10.4 -11.1 04/11/2005 20:40:00 6.2 0.9 8.4 3.4 5.5 0.8 7.2 3.4 0.4 0 0.4 0.4 87 9 92 305 21 0 22 0 -10.9 0 -10.7 -11.1 04/11/2005 20:50:00 7.3 0.7 8.8 4.9 6.6 0.7 8 4.6 0.4 0 0.4 0.4 96 6 100 305 21 0 21 0 -10.9 0 -10.4 -10.9 04/11/2005 21:00:00 6.2 1.5 9.1 1.9 5.4 1.2 8.4 1.9 0.4 0 0.4 0.4 81 22 98 305 21 0 21 0 -10.9 0 -10.7 -11.1 04/11/2005 21:10:00 4 1.8 8.4 0.4 3.5 1.3 6.8 0.4 0.4 0 0.4 0.4 76 49 106 305 21 0 21 0 -11 0 -10.7 -11.3 04/11/2005 21:20:00 2.7 1.3 6.5 0.4 2.5 1.1 6.1 0.4 0.4 0 0.4 0.4 86 49 121 305 21 0 21 0 -10.9 0 -10.4 -11.3 04/11/2005 21:30:00 2.9 1.4 7.2 0.4 2.4 1.4 7.2 0.4 0.4 0 0.4 0.4 118 41 120 305 21 0 21 0 -10.7 0.1 -10.2 -10.9 04/11/2005 21:40:00 4.3 1.4 7.2 0.4 3.8 1.2 6.5 0.7 0.4 0 0.4 0.4 67 45 108 305 21 0 21 0 -10.7 0.1 -10.4 -11.1 04/11/2005 21:50:00 3.6 1.3 6.5 0.4 3 1.3 6.1 0.4 0.4 0 0.4 0.4 87 51 61 305 21 0 21 0 -10.9 0 -10.4 -11.3 04/11/2005 22:00:00 5.7 1.5 8 0.7 5 1.3 7.2 1.5 0.4 0 0.4 0.4 96 27 93 305 21 0 21 0 -11.2 0.1 -10.9 -11.5 04/11/2005 22:10:00 6.4 0.9 9.5 4.6 5.8 0.8 8.4 3.4 0.4 0 0.4 0.4 77 11 81 305 21 0 21 0 -11.3 0.1 -10.9 -11.5 04/11/2005 22:20:00 5.4 1 7.6 2.6 5 1 7.6 2.3 0.4 0 0.4 0.4 69 15 77 305 20 0 21 0 -11.3 0.1 -10.9 -11.5 04/11/2005 22:30:00 4.7 1 8 2.6 4.5 0.9 7.6 2.6 0.4 0 0.4 0.4 56 17 64 305 20 0 20 0 -11.3 0.1 -10.9 -11.5 04/11/2005 22:40:00 4.2 0.9 6.5 1.9 4 1 6.5 1.5 0.4 0 0.4 0.4 45 16 61 305 20 0 20 0 -11.4 0.1 -11.1 -11.5 04/11/2005 22:50:00 4.2 1 6.5 1.9 3.9 1 6.5 1.1 0.4 0 0.4 0.4 48 15 62 305 20 0 20 0 -11.4 0.1 -11.1 -11.5 04/11/2005 23:00:00 5.1 0.8 7.2 2.3 4.9 0.9 6.8 1.5 0.4 0 0.4 0.4 48 12 54 305 20 0 20 0 -11.4 0 -11.1 -11.5 04/11/2005 23:10:00 3.6 1.1 6.5 1.1 3.3 1.1 6.5 0.7 0.4 0 0.4 0.4 56 18 53 305 20 0 20 0 -11.4 0.1 -10.9 -11.5 04/11/2005 23:20:00 3.6 1.1 6.8 1.9 3.1 1 6.5 1.1 0.4 0 0.4 0.4 57 18 66 305 20 0 20 0 -11.3 0.1 -10.9 -11.5 04/11/2005 23:30:00 2.3 1.1 4.6 0.4 1.9 1.1 4.6 0.4 0.4 0 0.4 0.4 66 47 63 305 20 0 20 0 -11.3 0.1 -11.1 -11.5 04/11/2005 23:40:00 3.8 1.5 7.6 1.1 3.5 1.4 7.2 0.7 0.4 0 0.4 0.4 67 23 88 305 20 0 20 0 -11.3 0 -10.9 -11.5 04/11/2005 23:50:00 3.9 1.2 6.8 1.5 3.6 1.2 6.8 1.5 0.4 0 0.4 0.4 75 24 75 305 20 0 20 0 -11.3 0.1 -10.9 -11.5 04/12/2005 00:00:00 3.4 1.3 6.5 0.7 3.1 1.3 6.1 0.4 0.4 0 0.4 0.4 69 30 86 305 20 0 20 0 -11.3 0 -10.9 -11.5 04/12/2005 00:10:00 4.5 1.3 8 1.5 4 1.2 7.2 0.4 0.4 0 0.4 0.4 70 27 60 305 20 0 20 0 -11.2 0 -10.9 -11.3 04/12/2005 00:20:00 4.4 1.2 8.4 1.5 3.9 1.3 7.2 0.7 0.4 0 0.4 0.4 83 18 98 305 20 0 20 0 -11.2 0 -10.9 -11.3 04/12/2005 00:30:00 4.5 1.3 7.6 1.1 4.1 1.3 8 0.7 0.4 0 0.4 0.4 80 18 102 305 20 0 20 0 -11.2 0 -10.9 -11.3 04/12/2005 00:40:00 3.4 1.3 6.5 0.4 3 1.3 5.7 0.4 0.4 0 0.4 0.4 64 27 84 305 20 0 20 0 -11.2 0 -10.9 -11.3 04/12/2005 00:50:00 3 1.2 5.7 0.4 2.8 1.1 5.3 0.4 0.4 0 0.4 0.4 68 27 82 305 20 0 20 0 -11.2 0 -10.9 -11.3 04/12/2005 01:00:00 4.1 1.6 7.6 1.1 3.8 1.6 6.8 0.4 0.4 0 0.4 0.4 65 26 82 305 20 0 20 0 -11.2 0 -10.9 -11.3 04/12/2005 01:10:00 4.4 1.1 7.2 1.9 4.1 1 6.8 1.9 0.4 0 0.4 0.4 61 26 72 305 20 0 20 0 -11.1 0.1 -10.9 -11.3 04/12/2005 01:20:00 3.3 1.2 7.2 0.7 3.2 1.2 5.7 0.4 0.4 0 0.4 0.4 40 32 59 305 20 0 20 0 -11.2 0.1 -10.9 -11.5 04/12/2005 01:30:00 3.5 1 6.1 1.1 3.6 0.8 6.1 1.5 0.4 0 0.4 0.4 23 27 83 305 19 0 20 0 -11.2 0.1 -10.9 -11.5 04/12/2005 01:40:00 2.7 1 6.1 0.4 2.5 1 5.7 0.4 0.4 0 0.4 0.4 51 27 51 305 20 0 20 0 -11.3 0.1 -10.9 -11.5 04/12/2005 01:50:00 3.6 1.4 8 0.4 3.1 1.2 7.6 0.4 0.4 0 0.4 0.4 64 27 55 305 20 0 20 0 -11.2 0.1 -10.9 -11.5 04/12/2005 02:00:00 3.9 1.2 6.8 0.7 3.5 1.1 6.1 0.7 0.4 0 0.4 0.4 68 22 82 305 20 0 20 0 -11.2 0.1 -10.9 -11.5 04/12/2005 02:10:00 4.3 1.2 7.2 1.5 3.9 1.1 6.1 1.5 0.4 0 0.4 0.4 74 18 87 305 20 0 20 0 -11.2 0.1 -10.9 -11.5 04/12/2005 02:20:00 5.2 0.9 7.6 3.4 4.8 0.9 7.6 2.6 0.4 0 0.4 0.4 74 13 54 305 20 0 20 0 -11.3 0.1 -10.9 -11.5 04/12/2005 02:30:00 6.4 0.8 8.8 4.2 5.9 0.8 8.8 3.4 0.4 0 0.4 0.4 78 11 65 305 20 0 20 0 -11.3 0.1 -10.9 -11.5 04/12/2005 02:40:00 6.4 0.8 9.1 4.6 6 0.7 8 3.8 0.4 0 0.4 0.4 73 10 70 305 20 0 20 0 -11.3 0.1 -10.9 -11.5 04/12/2005 02:50:00 5.6 0.9 7.6 3.4 5.1 0.9 7.2 2.6 0.4 0 0.4 0.4 78 13 68 305 20 0 20 0 -11.2 0 -10.9 -11.3 04/12/2005 03:00:00 5.8 0.9 8 3.8 5.4 0.9 7.6 3 0.4 0 0.4 0.4 77 12 69 305 20 0 20 0 -11.2 0 -10.9 -11.3 04/12/2005 03:10:00 5.8 1 9.1 2.3 5.5 1 8.4 2.6 0.4 0 0.4 0.4 74 11 83 305 20 0 20 0 -11.2 0 -10.9 -11.3 04/12/2005 03:20:00 6.1 0.9 8 3.8 5.6 0.8 8 3.8 0.4 0 0.4 0.4 86 13 71 305 20 0 19 0 -11 0 -10.7 -11.3 04/12/2005 03:30:00 6.4 1 9.1 3.4 6 0.8 7.6 3.8 0.4 0 0.4 0.4 91 10 85 305 20 0 20 0 -11.1 0 -10.9 -11.3 04/12/2005 03:40:00 7.3 0.9 9.1 4.9 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 86 8 92 305 20 0 20 0 -11.1 0 -10.9 -11.3 04/12/2005 03:50:00 7.4 0.8 9.5 5.3 6.8 0.8 8.8 4.6 0.4 0 0.4 0.4 86 8 98 305 20 0 20 0 -11.1 0 -10.9 -11.3 04/12/2005 04:00:00 7.2 0.9 9.5 4.2 6.4 0.8 8.4 4.6 0.4 0 0.4 0.4 87 9 85 305 20 0 20 0 -11 0 -10.7 -11.3 04/12/2005 04:10:00 7.3 1.1 10.3 4.9 6.6 1 8.8 3.8 0.4 0 0.4 0.4 91 8 87 305 20 0 20 0 -11 0 -10.7 -11.1 04/12/2005 04:20:00 6.9 1 9.5 4.2 6.3 1 9.1 3.8 0.4 0 0.4 0.4 87 11 92 305 20 0 20 0 -10.8 0 -10.4 -10.9 04/12/2005 04:30:00 7.4 1.3 11.1 3.8 6.8 1.2 10.3 3.8 0.4 0 0.4 0.4 94 9 100 305 20 0 20 0 -10.8 0.1 -10.4 -10.9 04/12/2005 04:40:00 8 1.2 11.1 4.6 7.4 1.1 9.9 4.6 0.4 0 0.4 0.4 94 8 97 305 20 0 20 0 -10.8 0.1 -10.4 -10.9 04/12/2005 04:50:00 7.2 1 9.5 4.6 6.6 0.9 8.8 4.6 0.4 0 0.4 0.4 93 9 97 305 20 0 20 0 -10.7 0 -10.4 -10.9 04/12/2005 05:00:00 6.8 0.9 9.5 4.6 6.4 0.9 8.8 4.2 0.4 0 0.4 0.4 93 10 78 305 20 0 20 0 -10.5 0 -10.4 -10.9 04/12/2005 05:10:00 6.9 0.8 9.1 4.9 6.4 0.8 8.4 4.2 0.4 0 0.4 0.4 93 8 102 305 20 0 21 0 -10.4 0 -10.4 -10.7 04/12/2005 05:20:00 7.2 0.8 9.5 5.3 6.7 0.7 9.1 4.6 0.4 0 0.4 0.4 98 7 99 305 21 0 21 0 -10.4 0 -10.2 -10.4 04/12/2005 05:30:00 7.6 0.9 10.7 4.6 7 0.8 9.1 4.6 0.4 0 0.4 0.4 94 7 99 305 21 0 21 0 -10.4 0 -10.2 -10.4 04/12/2005 05:40:00 7.6 0.9 9.9 4.9 7 0.9 9.1 4.6 0.4 0 0.4 0.4 88 8 89 305 21 0 21 0 -10.4 0 -10 -10.4 04/12/2005 05:50:00 7.6 1.1 10.7 4.6 7 1.1 10.3 4.6 0.4 0 0.4 0.4 92 8 82 305 21 0 21 0 -10.2 0.1 -9.8 -10.4 04/12/2005 06:00:00 8.4 1 10.7 5.7 7.9 0.9 9.9 5.7 0.4 0 0.4 0.4 88 8 95 305 21 0 21 0 -10.2 0.1 -9.8 -10.4 04/12/2005 06:10:00 9.2 0.8 11.1 6.5 8.6 0.7 10.3 6.5 0.4 0 0.4 0.4 87 7 84 305 21 0 21 0 -10.3 0 -9.8 -10.4 04/12/2005 06:20:00 8.7 0.8 10.3 6.5 8.1 0.8 10.3 5.3 0.4 0 0.4 0.4 84 6 87 305 21 0 21 0 -10.3 0 -9.8 -10.4 04/12/2005 06:30:00 8.8 0.8 11.1 6.8 8.2 0.7 10.3 6.1 0.4 0 0.4 0.4 84 8 83 305 21 0 21 0 -10.2 0.1 -9.8 -10.4 04/12/2005 06:40:00 7.4 0.7 9.1 5.3 7 0.7 8.8 5.3 0.4 0 0.4 0.4 71 7 69 305 21 0 21 0 -10.4 0 -10 -10.4 04/12/2005 06:50:00 7.1 0.9 9.9 4.9 6.6 0.8 9.1 4.6 0.4 0 0.4 0.4 71 10 73 305 21 0 21 0 -10.4 0 -10 -10.4 04/12/2005 07:00:00 7.2 0.9 10.3 4.6 6.8 1 10.3 3.8 0.4 0 0.4 0.4 82 9 70 305 21 0 21 0 -10.2 0.1 -9.8 -10.4 04/12/2005 07:10:00 6.5 1 8.8 3.4 6 1 9.1 3.4 0.4 0 0.4 0.4 81 11 96 305 21 0 21 0 -10.2 0.1 -9.8 -10.4 04/12/2005 07:20:00 6.8 1.2 9.9 4.2 6.4 1.2 9.1 3.4 0.4 0 0.4 0.4 84 10 91 305 21 0 21 0 -10.2 0.1 -9.6 -10.4 04/12/2005 07:30:00 6.6 1.2 9.1 3.8 6.1 1.2 8.4 3 0.4 0 0.4 0.4 95 13 89 305 21 0 21 0 -10.1 0.2 -9.6 -10.4 04/12/2005 07:40:00 4.3 1.1 7.6 1.1 4 1 7.2 1.9 0.4 0 0.4 0.4 84 17 101 305 22 0 21 0 -9.9 0.1 -9.6 -10.2 04/12/2005 07:50:00 4.8 1.3 8 1.1 4.5 1.4 7.6 0.4 0.4 0 0.4 0.4 69 22 63 305 22 0 21 0 -10.1 0 -9.6 -10.2 04/12/2005 08:00:00 5 1.2 9.1 1.9 4.7 1.2 8.8 1.5 0.4 0 0.4 0.4 66 13 56 305 22 0 22 0 -10.1 0 -9.6 -10.2 04/12/2005 08:10:00 4.7 1.3 7.6 1.9 4.3 1.3 8.4 1.5 0.4 0 0.4 0.4 76 18 51 305 22 0 22 0 -9.8 0 -9.2 -10 04/12/2005 08:20:00 4 1.1 6.5 1.5 3.5 1.1 6.5 1.5 0.4 0 0.4 0.4 80 15 58 305 22 0 22 0 -9.7 0.1 -9.2 -9.8 04/12/2005 08:30:00 3.9 1.2 7.6 1.5 4 1.2 8 1.1 0.4 0 0.4 0.4 65 22 62 305 22 0 22 0 -9.8 0 -9.2 -10 04/12/2005 08:40:00 3.2 1.3 7.2 0.4 3 1.3 7.6 0.4 0.4 0 0.4 0.4 68 35 71 305 22 0 22 0 -9.9 0.1 -9.2 -10 04/12/2005 08:50:00 2 1.5 6.5 0.4 2 1.4 7.2 0.4 0.4 0 0.4 0.4 70 66 96 305 23 0 22 0 -9.5 0.1 -9.2 -9.8 04/12/2005 09:00:00 1.8 1.1 3.8 0.4 1.7 1.1 3.4 0.4 0.4 0 0.4 0.4 358 66 28 305 23 1 23 0 -9.5 0.1 -9.2 -9.6 04/12/2005 09:10:00 3.3 1 5.7 0.4 2.9 1 5.3 0.4 0.4 0 0.4 0.4 79 22 75 305 24 0 24 0 -9.4 0 -9.2 -9.6 04/12/2005 09:20:00 2.7 1.7 6.8 0.4 2.4 1.7 6.5 0.4 0.4 0 0.4 0.4 85 38 78 305 24 0 24 0 -9.4 0 -9.2 -9.6 04/12/2005 09:30:00 3 1.5 6.1 0.4 2.8 1.5 6.1 0.4 0.4 0 0.4 0.4 71 39 57 305 24 0 24 0 -9.4 0 -9.2 -9.6 04/12/2005 09:40:00 4.5 0.8 6.8 1.9 4.5 0.8 6.5 2.3 0.4 0 0.4 0.4 39 15 42 305 25 0 25 0 -9.8 0 -9.4 -10 04/12/2005 09:50:00 6.1 1.2 9.5 3.4 6.1 1.2 8.8 3 0.4 0 0.4 0.4 55 13 60 305 25 0 25 0 -9.8 0 -9.6 -9.8 04/12/2005 10:00:00 4.7 1.8 9.1 0.4 4.4 1.9 8.8 0.4 0.4 0 0.4 0.4 82 22 87 305 25 0 25 0 -9.2 0.2 -8.6 -9.6 04/12/2005 10:10:00 2.5 1.5 6.5 0.4 2.5 1.4 6.1 0.4 0.4 0 0.4 0.4 103 69 70 305 25 0 25 0 -8.7 0.1 -8.2 -8.8 04/12/2005 10:20:00 2.2 1.6 8 0.4 2.2 1.5 6.5 0.4 0.4 0 0.4 0.4 88 82 85 305 26 1 27 0 -8.5 0.1 -7.9 -8.8 04/12/2005 10:30:00 2.7 1.3 6.8 0.4 2.5 1.2 6.5 0.4 0.4 0 0.4 0.4 121 58 176 305 27 0 26 0 -8.2 0.1 -7.7 -8.6 04/12/2005 10:40:00 4.1 1.7 8 0.4 3.8 1.5 7.6 0.4 0.4 0 0.4 0.4 83 27 88 305 28 0 28 0 -8.4 0.1 -7.9 -8.8 04/12/2005 10:50:00 5.9 1.4 9.9 2.3 5.7 1.4 9.5 2.3 0.4 0 0.4 0.4 71 15 62 305 28 0 28 0 -8.8 0 -8.4 -9.2 04/12/2005 11:00:00 5.4 1.3 9.5 1.5 5.2 1.2 8.8 1.9 0.4 0 0.4 0.4 62 12 70 305 28 0 28 0 -8.9 0 -8.6 -9.2 04/12/2005 11:10:00 3.7 1.3 7.6 0.4 3.4 1.3 6.8 0.7 0.4 0 0.4 0.4 61 28 50 305 29 0 28 0 -8.5 0.2 -7.9 -8.8 04/12/2005 11:20:00 3.1 1 5.3 0.4 2.9 1.2 5.3 0.4 0.4 0 0.4 0.4 57 21 64 305 29 0 29 0 -8.1 0.2 -7.7 -8.4 04/12/2005 11:30:00 3.2 1.2 6.1 0.4 2.9 1.3 6.5 0.4 0.4 0 0.4 0.4 72 29 67 305 31 0 31 0 -7.9 0.1 -7.5 -8.2 04/12/2005 11:40:00 3.5 1.9 7.2 0.4 3.4 1.9 7.2 0.4 0.4 0 0.4 0.4 97 53 132 305 32 1 31 0 -7.5 0.2 -6.9 -7.7 04/12/2005 11:50:00 3.2 1.3 6.8 0.4 2.9 1.3 6.8 0.4 0.4 0 0.4 0.4 85 36 152 305 33 0 32 0 -7.4 0.2 -6.9 -7.7 04/12/2005 12:00:00 3.6 1.2 6.5 0.7 3.3 1.2 6.1 0.4 0.4 0 0.4 0.4 79 30 151 305 34 0 34 0 -7.2 0.1 -6.9 -7.7 04/12/2005 12:10:00 4.4 1.4 7.6 1.9 4 1.4 8 1.1 0.4 0 0.4 0.4 85 19 65 305 35 0 35 0 -7.2 0 -7.1 -7.5 04/12/2005 12:20:00 5 1.3 8.8 1.1 4.8 1.2 8.8 1.9 0.4 0 0.4 0.4 77 19 71 305 35 0 35 0 -7.3 0.1 -6.9 -7.7 04/12/2005 12:30:00 4 1.3 9.1 1.1 3.8 1.3 8.4 1.5 0.4 0 0.4 0.4 97 24 103 305 35 0 34 0 -7.4 0.2 -7.1 -7.7 04/12/2005 12:40:00 4.6 1.5 8.4 1.1 4.1 1.4 8.4 0.4 0.4 0 0.4 0.4 109 22 123 305 35 0 35 0 -7.1 0 -6.9 -7.3 04/12/2005 12:50:00 6.6 1.7 11.1 3 6.3 1.7 10.7 2.3 0.4 0 0.4 0.4 109 17 121 305 35 0 34 0 -7.3 0.1 -7.1 -7.5 04/12/2005 13:00:00 8.8 1.4 12.6 5.3 8.5 1.5 12.2 5.3 0.4 0 0.4 0.4 109 11 116 305 34 0 34 0 -7.6 0 -7.3 -7.7 04/12/2005 13:10:00 9.1 1.5 13 5.7 8.8 1.6 14.1 5.3 0.4 0 0.4 0.4 110 13 119 305 34 0 34 0 -7.5 0 -7.3 -7.7 04/12/2005 13:20:00 9.5 1.4 13 5.3 9.1 1.3 12.6 4.9 0.4 0 0.4 0.4 111 11 97 305 33 0 33 0 -7.5 0 -7.3 -7.7 04/12/2005 13:30:00 7.4 1.5 11.5 3 7.2 1.6 11.8 3 0.4 0 0.4 0.4 107 17 93 305 33 0 33 0 -7.2 0 -7.1 -7.5 04/12/2005 13:40:00 6.6 1.8 10.3 1.9 6.1 1.7 9.9 2.3 0.4 0 0.4 0.4 97 18 132 305 34 0 34 0 -7.1 0 -6.9 -7.3 04/12/2005 13:50:00 6.9 1.7 12.6 3.4 6.5 1.7 10.7 1.5 0.4 0 0.4 0.4 91 24 73 305 34 0 34 0 -7.1 0 -6.9 -7.3 04/12/2005 14:00:00 5 2.3 11.1 0.4 4.7 2.3 10.7 0.4 0.4 0 0.4 0.4 82 39 51 305 34 0 34 0 -7 0 -6.7 -7.3 04/12/2005 14:10:00 6.3 2.1 11.5 1.5 5.8 2.1 11.8 0.4 0.4 0 0.4 0.4 71 22 82 305 35 0 35 0 -6.9 0.1 -6.7 -7.3 04/12/2005 14:20:00 5.2 1.7 9.9 1.5 4.8 1.7 9.1 1.5 0.4 0 0.4 0.4 90 24 77 305 35 0 35 0 -6.7 0.3 -6.2 -7.1 04/12/2005 14:30:00 2.2 1.2 4.9 0.4 2.2 1.1 5.3 0.4 0.4 0 0.4 0.4 71 47 129 305 36 1 38 0 -6.3 0 -6 -6.7 04/12/2005 14:40:00 3.7 1.7 9.1 0.7 3.3 1.5 8.4 0.4 0.4 0 0.4 0.4 73 58 83 305 38 0 38 0 -5.9 0.1 -5.8 -6.4 04/12/2005 14:50:00 2.9 1 5.3 0.4 2.9 1.1 5.3 0.4 0.4 0 0.4 0.4 20 56 35 305 40 1 39 0 -6.5 0.2 -6.2 -6.9 04/12/2005 15:00:00 4.2 1.2 7.6 1.5 4.2 1.3 7.6 1.5 0.4 0 0.4 0.4 43 21 46 305 42 0 42 0 -7.1 0.1 -6.7 -7.3 04/12/2005 15:10:00 5.7 1.7 9.5 0.7 5.3 1.6 9.5 1.1 0.4 0 0.4 0.4 62 20 56 305 43 0 43 0 -7.1 0 -6.7 -7.3 04/12/2005 15:20:00 8 1.8 12.2 3.4 7.6 1.7 12.6 3.4 0.4 0 0.4 0.4 71 13 72 305 43 0 43 0 -7.1 0 -6.9 -7.3 04/12/2005 15:30:00 8.5 1.5 12.2 4.9 7.9 1.5 11.8 4.9 0.4 0 0.4 0.4 78 11 91 305 42 0 42 0 -7 0 -6.9 -7.3 04/12/2005 15:40:00 8.7 1.9 13.3 3.8 8.3 1.7 12.2 4.6 0.4 0 0.4 0.4 97 13 92 305 42 0 42 0 -6.8 0 -6.7 -7.1 04/12/2005 15:50:00 11.1 1.2 14.1 6.8 10.3 1.3 14.1 6.8 0.4 0 0.4 0.4 101 10 105 305 41 0 41 0 -6.9 0 -6.7 -7.1 04/12/2005 16:00:00 10.3 1.5 16.1 6.5 9.6 1.5 13.7 6.1 0.4 0 0.4 0.4 101 12 99 305 40 0 40 0 -6.9 0 -6.9 -7.1 04/12/2005 16:10:00 11.6 1.5 15.6 7.6 10.9 1.3 14.5 7.2 0.4 0 0.4 0.4 103 9 90 305 40 0 40 0 -7 0 -6.9 -7.1 04/12/2005 16:20:00 10.5 1.7 14.1 6.1 9.9 1.7 14.1 4.9 0.4 0 0.4 0.4 101 13 116 305 40 0 39 0 -7 0 -6.7 -7.1 04/12/2005 16:30:00 11.9 1.5 15.3 7.2 11.1 1.5 14.1 6.5 0.4 0 0.4 0.4 106 8 109 305 39 0 39 0 -7 0.1 -6.7 -7.1 04/12/2005 16:40:00 13.3 1 16.1 10.3 12.7 0.9 15.6 10.3 0.4 0 0.4 0.4 109 6 94 305 39 0 39 0 -7.1 0 -6.9 -7.1 04/12/2005 16:50:00 13.2 0.8 15.3 10.7 12.4 0.7 14.5 10.3 0.4 0 0.4 0.4 107 5 116 305 39 0 39 0 -7.1 0 -6.9 -7.3 04/12/2005 17:00:00 11.1 1.2 13.7 8 10.4 1.2 13 6.8 0.4 0 0.4 0.4 108 7 114 305 39 0 39 0 -7 0 -6.9 -7.3 04/12/2005 17:10:00 11.9 1 14.1 9.5 11.3 0.9 13.7 9.1 0.4 0 0.4 0.4 107 6 116 305 39 0 39 0 -7.1 0 -6.9 -7.1 04/12/2005 17:20:00 12.7 0.9 15.6 10.3 12.1 0.9 14.9 10.3 0.4 0 0.4 0.4 106 6 109 305 38 0 38 0 -7.1 0 -6.9 -7.3 04/12/2005 17:30:00 13.1 0.6 14.5 11.1 12.3 0.7 14.1 9.9 0.4 0 0.4 0.4 104 4 105 305 38 0 38 0 -7.2 0 -7.1 -7.3 04/12/2005 17:40:00 13.3 0.6 14.9 11.1 12.5 0.7 14.5 10.3 0.4 0 0.4 0.4 104 4 108 305 38 0 38 0 -7.3 0 -7.1 -7.5 04/12/2005 17:50:00 13.7 0.7 15.3 11.5 12.9 0.7 14.9 10.3 0.4 0 0.4 0.4 105 3 106 305 38 0 38 0 -7.5 0 -7.3 -7.5 04/12/2005 18:00:00 13.3 0.7 14.9 10.3 12.5 0.8 14.5 9.9 0.4 0 0.4 0.4 102 4 103 305 38 0 38 0 -7.5 0 -7.3 -7.7 04/12/2005 18:10:00 11.4 1.4 14.5 8 10.7 1.3 13.3 7.2 0.4 0 0.4 0.4 102 8 109 305 38 0 38 0 -7.4 0 -7.1 -7.7 04/12/2005 18:20:00 11.4 1.1 13.7 8 10.7 1.1 13.7 7.6 0.4 0 0.4 0.4 102 7 103 305 38 0 38 0 -7.4 0 -7.3 -7.7 04/12/2005 18:30:00 13.1 1 15.6 9.5 12.3 0.9 14.5 9.1 0.4 0 0.4 0.4 102 5 99 305 38 0 38 0 -7.6 0 -7.3 -7.7 04/12/2005 18:40:00 12.9 1.2 15.6 8.8 12.2 1.1 14.9 8.4 0.4 0 0.4 0.4 101 6 104 305 38 0 38 0 -7.6 0 -7.3 -7.7 04/12/2005 18:50:00 13.4 1 15.6 9.5 12.6 1.1 15.3 9.5 0.4 0 0.4 0.4 102 6 109 305 38 0 38 0 -7.5 0 -7.3 -7.7 04/12/2005 19:00:00 13.7 1.1 16.1 9.9 13 1.1 15.3 9.9 0.4 0 0.4 0.4 104 6 113 305 38 0 38 0 -7.4 0 -7.3 -7.5 04/12/2005 19:10:00 13.5 1 16.1 9.5 12.7 1 14.9 10.3 0.4 0 0.4 0.4 104 5 101 305 38 0 38 0 -7.4 0 -7.3 -7.5 04/12/2005 19:20:00 12.9 0.9 15.3 10.3 12.1 0.8 14.1 9.5 0.4 0 0.4 0.4 104 5 99 305 38 0 38 0 -7.4 0 -7.1 -7.5 04/12/2005 19:30:00 12 1.1 15.3 8.8 11.3 1 14.5 8.4 0.4 0 0.4 0.4 102 5 99 305 38 0 38 0 -7.4 0 -7.1 -7.5 04/12/2005 19:40:00 12.4 1.2 14.9 8 11.7 1.2 14.9 7.6 0.4 0 0.4 0.4 103 5 111 305 38 0 38 0 -7.2 0 -7.1 -7.5 04/12/2005 19:50:00 12.8 1 14.9 9.9 12.2 1.1 14.5 8.8 0.4 0 0.4 0.4 101 6 105 305 38 0 38 0 -7.1 0 -6.9 -7.3 04/12/2005 20:00:00 10.9 1.2 13.3 6.5 10.3 1.1 13 7.6 0.4 0 0.4 0.4 102 9 106 305 38 0 39 0 -7.1 0 -6.9 -7.3 04/12/2005 20:10:00 12.3 1.3 16.4 8.8 11.7 1.3 14.9 8.4 0.4 0 0.4 0.4 103 6 98 305 39 0 39 0 -7.1 0 -6.9 -7.3 04/12/2005 20:20:00 12.2 1.3 15.3 8.8 11.6 1.3 15.6 8.4 0.4 0 0.4 0.4 104 7 121 305 39 0 39 0 -7.1 0 -6.9 -7.3 04/12/2005 20:30:00 11.9 1.4 14.9 8.4 11.2 1.4 14.1 6.8 0.4 0 0.4 0.4 104 9 118 305 39 0 39 0 -7 0.1 -6.7 -7.1 04/12/2005 20:40:00 12.1 1.2 16.4 6.8 11.4 1.2 15.3 6.8 0.4 0 0.4 0.4 103 7 114 305 39 0 39 0 -6.8 0 -6.7 -6.9 04/12/2005 20:50:00 9.8 1.5 14.5 5.3 9.4 1.5 14.1 5.3 0.4 0 0.4 0.4 101 12 116 305 39 0 39 0 -6.8 0 -6.4 -6.9 04/12/2005 21:00:00 9.3 1.5 13 5.7 8.7 1.5 13 4.9 0.4 0 0.4 0.4 98 12 101 305 40 0 40 0 -6.8 0 -6.7 -6.9 04/12/2005 21:10:00 9.7 1.3 12.6 5.7 9.1 1.2 12.2 5.7 0.4 0 0.4 0.4 98 10 98 305 40 0 40 0 -6.8 0 -6.7 -7.1 04/12/2005 21:20:00 9.8 1.5 14.1 6.1 9.3 1.6 14.5 5.3 0.4 0 0.4 0.4 91 11 77 305 40 0 40 0 -6.8 0.1 -6.4 -6.9 04/12/2005 21:30:00 10.4 1.5 14.9 5.7 9.8 1.5 13 6.1 0.4 0 0.4 0.4 96 11 103 305 40 0 40 0 -7 0 -6.7 -7.1 04/12/2005 21:40:00 10.8 1.3 14.1 7.6 10.2 1.2 13.7 7.2 0.4 0 0.4 0.4 98 11 122 305 40 0 40 0 -6.9 0 -6.7 -6.9 04/12/2005 21:50:00 11.3 1.3 15.6 8 10.7 1.3 14.5 7.2 0.4 0 0.4 0.4 98 9 103 305 40 0 40 0 -6.9 0 -6.7 -7.1 04/12/2005 22:00:00 12.1 1.3 15.3 8.8 11.6 1.2 14.9 8 0.4 0 0.4 0.4 99 8 97 305 40 0 40 0 -7 0 -6.9 -7.1 04/12/2005 22:10:00 12.4 1.4 15.6 8 11.8 1.3 15.6 8 0.4 0 0.4 0.4 100 8 96 305 40 0 40 0 -7 0 -6.9 -7.3 04/12/2005 22:20:00 12.2 1.5 16.8 8.8 11.5 1.3 14.9 8.4 0.4 0 0.4 0.4 101 8 104 305 40 0 40 0 -7.1 0 -7.1 -7.3 04/12/2005 22:30:00 11.2 1.3 14.5 8 10.6 1.2 13.3 7.6 0.4 0 0.4 0.4 99 7 100 305 39 0 40 0 -7.1 0 -6.9 -7.3 04/12/2005 22:40:00 11 1.2 13.7 6.8 10.6 1.1 13.3 7.2 0.4 0 0.4 0.4 91 9 99 305 39 0 39 0 -7.1 0 -6.9 -7.1 04/12/2005 22:50:00 11 1.7 15.3 4.9 10.4 1.6 14.9 6.1 0.4 0 0.4 0.4 91 12 62 305 39 0 39 0 -7.2 0 -6.9 -7.5 04/12/2005 23:00:00 10.9 1.5 14.5 6.8 10.3 1.4 13.7 7.2 0.4 0 0.4 0.4 91 10 92 305 39 0 39 0 -7.1 0 -7.1 -7.3 04/12/2005 23:10:00 11 1.5 14.5 6.8 10.4 1.4 14.1 7.2 0.4 0 0.4 0.4 90 9 89 305 39 0 39 0 -7.1 0 -6.9 -7.3 04/12/2005 23:20:00 11 1.3 14.5 7.6 10.5 1.4 14.5 6.8 0.4 0 0.4 0.4 93 10 92 305 39 0 39 0 -7.1 0 -6.9 -7.3 04/12/2005 23:30:00 11.3 1.1 14.1 8.8 10.7 1.1 13.7 8.4 0.4 0 0.4 0.4 96 9 89 305 39 0 39 0 -7 0.1 -6.7 -7.3 04/12/2005 23:40:00 11.3 1.1 14.9 8 10.7 1.2 15.3 7.6 0.4 0 0.4 0.4 94 9 75 305 39 0 39 0 -7 0.1 -6.9 -7.1 04/12/2005 23:50:00 11.8 1.3 16.1 8.4 11.2 1.2 13.7 8 0.4 0 0.4 0.4 91 8 90 305 39 0 39 0 -7.1 0 -6.9 -7.3 04/13/2005 00:00:00 12.2 0.9 16.1 9.5 11.6 1 14.5 9.1 0.4 0 0.4 0.4 87 7 109 305 39 0 39 0 -7.3 0.1 -6.9 -7.5 04/13/2005 00:10:00 12 1.1 14.9 8 11.5 1.2 15.3 8 0.4 0 0.4 0.4 88 7 85 305 39 0 39 0 -7.5 0 -7.3 -7.7 04/13/2005 00:20:00 11.9 1 14.9 8.8 11.4 1.1 14.5 8.8 0.4 0 0.4 0.4 88 7 89 305 38 0 39 0 -7.6 0 -7.3 -7.7 04/13/2005 00:30:00 11.6 1 14.5 8.4 11 1 13.3 8 0.4 0 0.4 0.4 88 6 90 305 38 0 38 0 -7.6 0 -7.3 -7.7 04/13/2005 00:40:00 11.1 1.1 13.3 7.6 10.5 1 12.6 7.2 0.4 0 0.4 0.4 89 6 87 305 38 0 38 0 -7.6 0 -7.3 -7.7 04/13/2005 00:50:00 9.6 1 13 6.5 9.1 1.1 13 5.7 0.4 0 0.4 0.4 88 7 89 305 38 0 38 0 -7.3 0 -7.1 -7.7 04/13/2005 01:00:00 8.5 1 11.1 6.1 8.1 1.1 10.3 5.7 0.4 0 0.4 0.4 82 9 89 305 38 0 38 0 -7.3 0 -7.1 -7.5 04/13/2005 01:10:00 8.1 0.9 10.3 5.7 7.8 0.9 9.9 5.3 0.4 0 0.4 0.4 75 9 60 305 38 0 38 0 -7.4 0 -7.3 -7.7 04/13/2005 01:20:00 8 0.7 10.3 6.5 7.6 0.8 9.9 6.1 0.4 0 0.4 0.4 70 5 73 305 38 0 38 0 -7.6 0 -7.3 -7.7 04/13/2005 01:30:00 8.1 0.6 9.9 6.5 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 69 5 72 305 38 0 38 0 -7.7 0 -7.7 -7.9 04/13/2005 01:40:00 9 0.7 10.7 7.2 8.5 0.7 10.7 6.5 0.4 0 0.4 0.4 76 6 79 305 38 0 38 0 -7.7 0 -7.7 -7.9 04/13/2005 01:50:00 9.4 0.9 11.8 6.8 8.8 0.9 11.1 6.5 0.4 0 0.4 0.4 78 6 78 305 38 0 38 0 -7.8 0 -7.7 -7.9 04/13/2005 02:00:00 9.2 0.7 11.5 7.6 8.6 0.8 10.7 6.5 0.4 0 0.4 0.4 76 6 71 305 37 0 38 0 -7.8 0 -7.7 -7.9 04/13/2005 02:10:00 9.1 0.8 11.1 6.8 8.5 0.8 11.1 6.1 0.4 0 0.4 0.4 75 6 70 305 37 0 37 0 -7.7 0 -7.5 -7.9 04/13/2005 02:20:00 8.8 0.8 11.1 6.5 8.4 0.8 10.7 6.5 0.4 0 0.4 0.4 73 7 77 305 37 0 37 0 -7.8 0 -7.7 -7.9 04/13/2005 02:30:00 8.7 0.8 10.7 6.8 8.3 0.8 10.7 6.1 0.4 0 0.4 0.4 69 6 65 305 37 0 37 0 -7.8 0 -7.7 -7.9 04/13/2005 02:40:00 8.5 0.8 10.7 6.1 8.1 0.9 9.9 6.1 0.4 0 0.4 0.4 68 7 69 305 37 0 37 0 -7.9 0 -7.7 -8.2 04/13/2005 02:50:00 7.8 1 10.3 5.3 7.4 1 10.3 4.9 0.4 0 0.4 0.4 70 10 80 305 37 0 37 0 -8 0.1 -7.7 -8.2 04/13/2005 03:00:00 7 1 9.5 4.6 6.6 1 8.8 4.2 0.4 0 0.4 0.4 64 11 71 305 36 0 36 0 -8.1 0 -7.7 -8.2 04/13/2005 03:10:00 6.3 1.3 9.5 3.4 5.9 1.4 9.1 2.6 0.4 0 0.4 0.4 51 12 66 305 36 0 36 0 -8.2 0 -7.7 -8.4 04/13/2005 03:20:00 6.5 1.1 9.1 4.2 5.9 1.1 8.8 3 0.4 0 0.4 0.4 55 13 67 305 36 0 36 0 -8.2 0 -7.9 -8.4 04/13/2005 03:30:00 6.8 1.1 9.5 4.2 6.3 1.1 9.1 3.8 0.4 0 0.4 0.4 62 12 91 305 36 0 36 0 -8.3 0 -7.9 -8.4 04/13/2005 03:40:00 6.6 1.1 9.5 3.8 5.9 1.2 9.1 3 0.4 0 0.4 0.4 62 13 68 305 36 0 36 0 -8.4 0 -8.2 -8.6 04/13/2005 03:50:00 6.2 1.1 9.1 3 5.6 1.1 8.8 3 0.4 0 0.4 0.4 57 16 51 305 35 0 35 0 -8.6 0.1 -8.2 -8.8 04/13/2005 04:00:00 5.9 1 8.4 3.4 5.4 1 7.6 3 0.4 0 0.4 0.4 53 15 72 305 35 0 35 0 -8.7 0 -8.4 -8.8 04/13/2005 04:10:00 6.7 1.1 9.1 3 6.2 1 8.8 2.6 0.4 0 0.4 0.4 55 11 82 305 35 0 35 0 -8.8 0 -8.6 -9 04/13/2005 04:20:00 6.1 1 8.8 3.4 5.7 1 8.8 3.4 0.4 0 0.4 0.4 53 13 57 305 34 0 34 0 -8.8 0 -8.6 -9.2 04/13/2005 04:30:00 7 1.1 9.5 4.6 6.4 1.1 8.8 3.4 0.4 0 0.4 0.4 59 13 75 305 34 0 34 0 -8.9 0 -8.6 -9 04/13/2005 04:40:00 7.8 0.9 10.7 5.7 7.5 0.9 9.9 5.3 0.4 0 0.4 0.4 56 10 59 305 34 0 34 0 -8.8 0 -8.6 -9 04/13/2005 04:50:00 7.9 0.8 10.3 5.7 7.7 0.9 9.9 5.3 0.4 0 0.4 0.4 55 9 68 305 34 0 34 0 -8.8 0 -8.8 -9 04/13/2005 05:00:00 8.1 0.7 10.7 6.5 7.8 0.8 9.9 5.7 0.4 0 0.4 0.4 58 8 70 305 33 0 33 0 -8.9 0 -8.6 -9 04/13/2005 05:10:00 7.6 0.9 9.9 5.3 7.3 0.9 9.9 4.9 0.4 0 0.4 0.4 56 9 66 305 33 0 33 0 -8.8 0 -8.6 -9 04/13/2005 05:20:00 7.6 1 10.3 4.9 7.4 1 10.3 4.6 0.4 0 0.4 0.4 55 9 71 305 33 0 33 0 -8.8 0 -8.6 -9 04/13/2005 05:30:00 7.9 0.7 9.9 5.7 7.7 0.8 10.3 5.7 0.4 0 0.4 0.4 53 7 76 305 33 0 33 0 -8.8 0 -8.6 -9 04/13/2005 05:40:00 9 0.8 11.5 7.2 8.8 0.8 11.1 6.5 0.4 0 0.4 0.4 54 6 60 305 33 0 33 0 -8.8 0 -8.6 -8.8 04/13/2005 05:50:00 9.5 1 11.8 6.8 9.1 1 11.8 5.7 0.4 0 0.4 0.4 63 9 56 305 33 0 33 0 -8.8 0 -8.4 -9 04/13/2005 06:00:00 10.6 1.1 13.3 7.6 9.9 1.1 12.6 6.8 0.4 0 0.4 0.4 73 7 85 305 33 0 33 0 -8.6 0.1 -8.2 -8.8 04/13/2005 06:10:00 12.1 1.1 14.9 9.1 11.3 1.1 14.1 8 0.4 0 0.4 0.4 81 6 85 305 33 0 33 0 -8.5 0.1 -8.2 -8.8 04/13/2005 06:20:00 13.2 0.8 15.3 11.5 12.4 0.8 14.5 10.7 0.4 0 0.4 0.4 85 4 84 305 33 0 33 0 -8.4 0 -7.9 -8.8 04/13/2005 06:30:00 13.1 0.8 15.3 11.1 12.4 0.8 14.5 10.3 0.4 0 0.4 0.4 84 5 81 305 33 0 33 0 -8.2 0 -7.7 -8.4 04/13/2005 06:40:00 12.3 0.9 14.9 9.1 11.8 0.8 13.7 9.1 0.4 0 0.4 0.4 80 6 78 305 33 0 33 0 -8 0.1 -7.7 -8.2 04/13/2005 06:50:00 12 0.9 14.1 9.1 11.4 0.9 14.1 9.1 0.4 0 0.4 0.4 78 6 76 305 34 0 34 0 -8.2 0 -7.7 -8.4 04/13/2005 07:00:00 11.6 0.8 13.3 9.1 11.1 0.8 13.3 8.8 0.4 0 0.4 0.4 74 6 82 305 34 0 33 0 -8.3 0 -7.9 -8.4 04/13/2005 07:10:00 11.7 0.6 13 9.5 11.6 0.7 13 9.5 0.4 0 0.4 0.4 64 5 67 305 34 0 34 0 -8.3 0 -7.9 -8.4 04/13/2005 07:20:00 11 0.7 12.2 9.1 10.8 0.7 12.2 8.8 0.4 0 0.4 0.4 62 4 69 305 33 0 34 0 -8.3 0 -8.2 -8.6 04/13/2005 07:30:00 11.2 0.6 13 9.1 10.9 0.7 12.6 8.4 0.4 0 0.4 0.4 63 4 70 305 33 0 33 0 -8.3 0 -7.9 -8.6 04/13/2005 07:40:00 11.4 0.6 13 9.5 11.2 0.7 13 9.1 0.4 0 0.4 0.4 67 5 67 305 33 0 34 0 -8.2 0 -7.7 -8.4 04/13/2005 07:50:00 11.5 0.7 13.3 9.5 11.3 0.8 13.3 9.1 0.4 0 0.4 0.4 68 5 64 305 34 0 34 0 -8 0 -7.7 -8.2 04/13/2005 08:00:00 11.8 0.6 13.7 9.9 11.5 0.7 13.3 9.5 0.4 0 0.4 0.4 71 5 72 305 34 0 34 0 -7.9 0 -7.5 -8.2 04/13/2005 08:10:00 11.6 0.6 13.3 9.9 11.5 0.6 13 9.9 0.4 0 0.4 0.4 66 4 64 305 34 0 34 0 -7.8 0 -7.5 -7.9 04/13/2005 08:20:00 11.3 0.5 12.6 9.9 11.2 0.6 12.6 9.9 0.4 0 0.4 0.4 64 3 70 305 34 0 34 0 -7.9 0 -7.7 -8.2 04/13/2005 08:30:00 10.7 0.4 11.5 9.5 10.5 0.5 11.5 9.1 0.4 0 0.4 0.4 63 3 62 305 34 0 34 0 -7.8 0 -7.5 -7.9 04/13/2005 08:40:00 10.6 0.4 11.5 9.5 10.4 0.4 11.5 9.5 0.4 0 0.4 0.4 62 3 62 305 35 0 34 0 -7.7 0 -7.3 -7.7 04/13/2005 08:50:00 10.4 0.4 11.5 8.8 10.3 0.5 11.5 8.4 0.4 0 0.4 0.4 61 3 59 305 35 0 35 0 -7.5 0.1 -7.1 -7.7 04/13/2005 09:00:00 10.7 0.5 11.8 9.5 10.6 0.5 11.8 9.1 0.4 0 0.4 0.4 61 2 64 305 35 0 35 0 -7.3 0 -6.9 -7.5 04/13/2005 09:10:00 10.2 0.4 11.5 9.1 10.1 0.5 11.5 8.8 0.4 0 0.4 0.4 61 3 62 305 36 0 35 0 -7.1 0 -6.9 -7.3 04/13/2005 09:20:00 9.9 0.5 11.1 8.4 9.8 0.5 11.1 8.4 0.4 0 0.4 0.4 59 3 64 305 36 0 36 0 -7.1 0 -6.9 -7.3 04/13/2005 09:30:00 10.1 0.5 11.5 8.8 10 0.6 11.5 8.4 0.4 0 0.4 0.4 59 3 59 305 37 0 37 0 -7 0.1 -6.7 -7.1 04/13/2005 09:40:00 9.9 0.5 11.5 8.4 9.8 0.6 11.5 8.4 0.4 0 0.4 0.4 59 3 64 305 37 0 37 0 -6.8 0 -6.7 -6.9 04/13/2005 09:50:00 10.3 0.6 11.5 8.8 10.2 0.7 11.5 8 0.4 0 0.4 0.4 59 3 62 305 38 0 38 0 -6.8 0 -6.4 -6.9 04/13/2005 10:00:00 10 0.5 11.5 8.8 9.9 0.5 11.5 8.8 0.4 0 0.4 0.4 59 3 61 305 38 0 38 0 -6.6 0 -6.4 -6.9 04/13/2005 10:10:00 9.8 0.4 10.7 8.4 9.7 0.5 11.1 8.4 0.4 0 0.4 0.4 57 3 55 305 39 0 39 0 -6.5 0 -6.2 -6.7 04/13/2005 10:20:00 9.5 0.5 10.3 8 9.3 0.6 10.7 7.6 0.4 0 0.4 0.4 56 4 57 305 40 0 40 0 -6.4 0 -6.2 -6.7 04/13/2005 10:30:00 9.7 0.5 11.1 8.4 9.6 0.6 11.1 8 0.4 0 0.4 0.4 53 4 56 305 41 0 41 0 -6.4 0 -6.2 -6.7 04/13/2005 10:40:00 9.8 0.5 10.7 8.4 9.7 0.6 11.1 8 0.4 0 0.4 0.4 53 5 45 305 42 0 41 0 -6.3 0 -6 -6.4 04/13/2005 10:50:00 9.9 0.6 11.5 8 9.8 0.6 11.1 8 0.4 0 0.4 0.4 51 3 53 305 42 0 42 0 -6.3 0 -6.2 -6.4 04/13/2005 11:00:00 9.9 0.5 11.1 8.4 9.9 0.5 11.1 8.4 0.4 0 0.4 0.4 53 3 54 305 43 0 43 0 -6.2 0 -6 -6.2 04/13/2005 11:10:00 9.8 0.6 11.5 8 9.7 0.7 11.1 7.6 0.4 0 0.4 0.4 50 5 53 305 44 0 43 0 -6.1 0 -6 -6.2 04/13/2005 11:20:00 9.5 0.3 10.3 8.8 9.4 0.4 10.7 8.4 0.4 0 0.4 0.4 44 3 42 305 45 0 45 0 -6.1 0 -5.8 -6.2 04/13/2005 11:30:00 9.9 0.4 10.7 8.8 9.8 0.4 10.7 8.4 0.4 0 0.4 0.4 44 2 42 305 45 0 46 0 -6.1 0 -6 -6.2 04/13/2005 11:40:00 10.3 0.4 11.1 9.1 10.3 0.4 11.5 9.1 0.4 0 0.4 0.4 50 3 49 305 46 0 46 0 -6.1 0 -6 -6.2 04/13/2005 11:50:00 10 0.5 11.1 8.4 9.9 0.6 11.1 8 0.4 0 0.4 0.4 51 4 52 305 47 0 47 0 -6 0 -5.8 -6 04/13/2005 12:00:00 10.4 0.4 11.5 9.1 10.3 0.5 11.5 8.8 0.4 0 0.4 0.4 48 4 53 305 47 0 47 0 -6 0 -5.8 -6 04/13/2005 12:10:00 10.6 0.4 11.5 9.1 10.4 0.5 11.5 8.4 0.4 0 0.4 0.4 46 3 43 305 48 0 47 0 -5.9 0 -5.8 -6 04/13/2005 12:20:00 10.7 0.4 11.8 9.1 10.7 0.5 11.8 8.8 0.4 0 0.4 0.4 49 4 46 305 48 0 48 0 -5.8 0 -5.8 -6 04/13/2005 12:30:00 10.9 0.5 12.2 9.1 10.8 0.6 12.2 9.1 0.4 0 0.4 0.4 49 4 54 305 49 0 49 0 -5.8 0 -5.6 -6 04/13/2005 12:40:00 10.8 0.5 12.2 9.5 10.6 0.6 11.8 9.1 0.4 0 0.4 0.4 48 3 54 305 50 0 49 0 -5.7 0 -5.6 -5.8 04/13/2005 12:50:00 11.4 0.5 12.6 10.3 11.3 0.6 12.6 9.1 0.4 0 0.4 0.4 47 3 46 305 50 0 50 0 -5.9 0.1 -5.6 -6 04/13/2005 13:00:00 11.7 0.5 13.3 10.3 11.6 0.6 13 9.9 0.4 0 0.4 0.4 45 3 40 305 51 0 51 0 -5.8 0 -5.8 -6 04/13/2005 13:10:00 11.9 0.6 13 10.3 11.9 0.6 13.3 9.9 0.4 0 0.4 0.4 46 3 43 305 51 0 51 0 -6 0 -5.8 -6 04/13/2005 13:20:00 11.7 0.5 12.6 9.9 11.6 0.6 12.6 9.5 0.4 0 0.4 0.4 44 3 49 305 52 0 52 0 -5.8 0 -5.8 -6 04/13/2005 13:30:00 11.7 0.6 13.3 9.5 11.7 0.6 13.3 9.5 0.4 0 0.4 0.4 46 4 46 305 52 0 52 0 -5.9 0 -5.8 -6 04/13/2005 13:40:00 11.5 0.6 13 9.5 11.4 0.8 13.3 9.5 0.4 0 0.4 0.4 43 4 44 305 52 0 53 0 -6 0 -5.8 -6 04/13/2005 13:50:00 11.6 0.7 13.3 9.5 11.6 0.7 13.3 9.1 0.4 0 0.4 0.4 47 3 48 305 53 0 53 0 -6.1 0 -5.8 -6.2 04/13/2005 14:00:00 11.5 0.7 12.6 9.5 11.4 0.8 12.6 9.1 0.4 0 0.4 0.4 46 4 52 305 53 0 53 0 -6 0 -5.8 -6.2 04/13/2005 14:10:00 11.4 0.5 12.6 9.9 11.4 0.5 12.6 9.5 0.4 0 0.4 0.4 44 3 43 305 53 0 53 0 -6.1 0 -6 -6.2 04/13/2005 14:20:00 11.5 0.5 12.6 10.3 11.6 0.5 13 9.9 0.4 0 0.4 0.4 46 3 49 305 54 0 54 0 -6.1 0 -5.8 -6.2 04/13/2005 14:30:00 11.5 0.5 12.6 9.9 11.4 0.5 12.6 9.9 0.4 0 0.4 0.4 43 4 41 305 54 0 54 0 -6.1 0 -5.8 -6.2 04/13/2005 14:40:00 11.6 0.5 12.6 9.5 11.5 0.6 12.6 9.5 0.4 0 0.4 0.4 41 3 44 305 54 0 54 0 -6.1 0 -5.8 -6.2 04/13/2005 14:50:00 11.7 0.5 13 9.9 11.7 0.6 13 9.5 0.4 0 0.4 0.4 45 3 41 305 55 0 55 0 -6.1 0 -6 -6.4 04/13/2005 15:00:00 11.7 0.5 12.6 9.9 11.6 0.6 13 9.9 0.4 0 0.4 0.4 43 4 48 305 55 0 55 0 -6.2 0 -5.8 -6.4 04/13/2005 15:10:00 12.1 0.5 13.3 10.7 12.1 0.6 13.7 10.7 0.4 0 0.4 0.4 44 4 43 305 55 0 55 0 -6.2 0.1 -6 -6.4 04/13/2005 15:20:00 11.6 0.5 13 10.3 11.5 0.6 13 9.5 0.4 0 0.4 0.4 43 4 39 305 55 0 55 0 -6.3 0 -6.2 -6.7 04/13/2005 15:30:00 12.2 0.5 13.3 10.3 12.1 0.6 13.3 10.3 0.4 0 0.4 0.4 42 4 46 305 55 0 55 0 -6.4 0 -6.2 -6.7 04/13/2005 15:40:00 12.7 0.5 14.1 11.1 12.6 0.6 13.7 10.7 0.4 0 0.4 0.4 43 2 43 305 55 0 55 0 -6.5 0 -6.4 -6.7 04/13/2005 15:50:00 12.6 0.5 14.1 10.7 12.6 0.6 13.7 10.7 0.4 0 0.4 0.4 46 3 45 305 55 0 55 0 -6.5 0 -6.2 -6.7 04/13/2005 16:00:00 12.2 0.5 13.3 10.3 12.1 0.6 13.3 10.3 0.4 0 0.4 0.4 41 4 44 305 55 0 55 0 -6.5 0 -6.4 -6.7 04/13/2005 16:10:00 12.8 0.5 13.7 10.3 12.7 0.6 14.1 9.9 0.4 0 0.4 0.4 39 3 36 305 55 0 55 0 -6.7 0 -6.7 -6.9 04/13/2005 16:20:00 12.4 0.6 14.1 10.7 12.3 0.7 14.1 10.3 0.4 0 0.4 0.4 42 4 42 305 55 0 55 0 -6.7 0 -6.7 -6.9 04/13/2005 16:30:00 12.2 0.6 13.7 10.7 12 0.8 13.7 9.9 0.4 0 0.4 0.4 41 4 46 305 55 0 55 0 -6.7 0 -6.7 -6.9 04/13/2005 16:40:00 12.4 0.7 14.1 10.7 12.2 0.8 14.1 9.9 0.4 0 0.4 0.4 42 4 45 305 55 0 55 0 -6.6 0 -6.4 -6.9 04/13/2005 16:50:00 12.4 0.6 13.7 10.3 12.2 0.7 13.7 9.9 0.4 0 0.4 0.4 45 5 43 305 55 0 55 0 -6.6 0 -6.4 -6.9 04/13/2005 17:00:00 12.1 0.8 13.7 10.3 12.1 0.8 14.1 9.9 0.4 0 0.4 0.4 45 5 43 305 55 0 55 0 -6.7 0 -6.7 -6.9 04/13/2005 17:10:00 11.8 0.6 13.7 9.9 11.6 0.7 14.1 9.9 0.4 0 0.4 0.4 43 5 48 305 55 0 55 0 -6.7 0 -6.7 -6.9 04/13/2005 17:20:00 11.4 0.6 13 9.9 11.3 0.7 13 9.5 0.4 0 0.4 0.4 42 4 44 305 55 0 55 0 -6.7 0 -6.7 -6.9 04/13/2005 17:30:00 10.8 0.7 13 9.1 10.6 0.8 13 8 0.4 0 0.4 0.4 42 5 54 305 55 0 55 0 -6.7 0 -6.7 -6.9 04/13/2005 17:40:00 11.8 0.8 13.3 9.5 11.8 0.9 13.3 8.8 0.4 0 0.4 0.4 44 4 43 305 55 0 55 0 -6.9 0 -6.7 -7.1 04/13/2005 17:50:00 12 0.6 13.3 9.9 11.9 0.7 13.3 9.5 0.4 0 0.4 0.4 44 4 47 305 55 0 55 0 -6.9 0.1 -6.7 -7.1 04/13/2005 18:00:00 12.2 0.6 13.7 10.3 12.1 0.6 13.7 9.9 0.4 0 0.4 0.4 41 4 46 305 55 0 55 0 -6.9 0 -6.9 -7.1 04/13/2005 18:10:00 12.1 0.6 13.3 9.9 12.1 0.6 13.3 9.9 0.4 0 0.4 0.4 40 3 36 305 55 0 55 0 -6.9 0 -6.9 -7.1 04/13/2005 18:20:00 12 0.7 13.3 9.9 12 0.8 13.3 9.5 0.4 0 0.4 0.4 38 4 40 305 55 0 55 0 -7 0 -6.7 -7.1 04/13/2005 18:30:00 11.8 0.6 13.3 10.3 11.7 0.6 13.3 9.9 0.4 0 0.4 0.4 38 3 33 305 55 0 54 0 -6.9 0 -6.7 -6.9 04/13/2005 18:40:00 11.5 0.6 13 9.9 11.4 0.7 13 9.5 0.4 0 0.4 0.4 40 4 47 305 55 0 55 0 -6.9 0 -6.7 -6.9 04/13/2005 18:50:00 11.8 0.7 13.3 9.9 11.7 0.8 13.7 9.5 0.4 0 0.4 0.4 43 3 37 305 55 0 55 0 -6.9 0 -6.7 -6.9 04/13/2005 19:00:00 11.9 0.6 13.3 10.3 11.8 0.7 13.3 9.5 0.4 0 0.4 0.4 39 3 36 305 54 0 54 0 -6.9 0 -6.7 -7.1 04/13/2005 19:10:00 11.5 0.6 13 9.9 11.4 0.6 12.6 9.1 0.4 0 0.4 0.4 38 3 39 305 54 0 54 0 -7 0 -6.9 -7.1 04/13/2005 19:20:00 10.9 0.6 12.6 9.5 10.8 0.7 12.6 8.4 0.4 0 0.4 0.4 44 5 49 305 54 0 54 0 -6.9 0 -6.7 -7.1 04/13/2005 19:30:00 11.3 0.6 13 9.1 11.1 0.7 12.6 9.1 0.4 0 0.4 0.4 43 5 44 305 54 0 54 0 -6.9 0 -6.9 -7.1 04/13/2005 19:40:00 11 0.5 12.2 9.5 10.8 0.6 12.2 9.1 0.4 0 0.4 0.4 37 3 40 305 54 0 54 0 -7 0 -6.9 -7.1 04/13/2005 19:50:00 10.9 0.6 12.2 9.5 10.8 0.7 12.6 9.1 0.4 0 0.4 0.4 37 4 34 305 54 0 54 0 -7.1 0 -6.9 -7.1 04/13/2005 20:00:00 11 0.6 12.2 9.1 10.9 0.7 12.6 8.8 0.4 0 0.4 0.4 36 3 40 305 54 0 54 0 -7.1 0 -6.9 -7.1 04/13/2005 20:10:00 11 0.7 12.6 9.1 10.9 0.8 13 8.4 0.4 0 0.4 0.4 37 4 35 305 53 0 53 0 -7.1 0 -6.9 -7.1 04/13/2005 20:20:00 11.5 0.7 13.3 9.5 11.3 0.8 13 8.8 0.4 0 0.4 0.4 38 4 41 305 53 0 53 0 -7.1 0 -6.9 -7.1 04/13/2005 20:30:00 11.7 0.6 13.3 10.3 11.6 0.6 13 9.5 0.4 0 0.4 0.4 39 3 40 305 53 0 53 0 -7.1 0 -6.9 -7.3 04/13/2005 20:40:00 12 0.6 13.3 10.3 11.9 0.7 13.3 9.9 0.4 0 0.4 0.4 40 3 40 305 52 0 53 0 -7.1 0 -7.1 -7.3 04/13/2005 20:50:00 11.7 0.5 13.3 10.3 11.5 0.6 13 9.9 0.4 0 0.4 0.4 39 4 40 305 52 0 52 0 -7.2 0 -7.1 -7.3 04/13/2005 21:00:00 11.7 0.7 13.7 9.5 11.6 0.8 14.1 9.1 0.4 0 0.4 0.4 43 4 44 305 51 0 52 0 -7.2 0 -7.1 -7.5 04/13/2005 21:10:00 11.2 0.7 13 9.1 11 0.7 13 9.1 0.4 0 0.4 0.4 42 4 41 305 51 0 51 0 -7.3 0 -7.1 -7.5 04/13/2005 21:20:00 11 0.7 12.6 9.1 10.9 0.8 12.6 9.1 0.4 0 0.4 0.4 43 4 42 305 50 0 51 0 -7.5 0 -7.3 -7.7 04/13/2005 21:30:00 10.5 0.7 12.6 8.8 10.3 0.8 12.6 8 0.4 0 0.4 0.4 42 4 39 305 50 0 50 0 -7.6 0 -7.3 -7.7 04/13/2005 21:40:00 11.1 0.7 13 9.1 11 0.8 13 8.8 0.4 0 0.4 0.4 43 3 46 305 49 0 50 0 -7.6 0 -7.3 -7.7 04/13/2005 21:50:00 10.5 0.8 12.6 8.8 10.3 0.8 12.2 8 0.4 0 0.4 0.4 41 5 44 305 49 0 49 0 -7.7 0 -7.5 -7.7 04/13/2005 22:00:00 10.2 0.7 12.6 8.8 10 0.8 12.2 8.4 0.4 0 0.4 0.4 42 4 44 305 48 0 48 0 -7.7 0 -7.5 -7.9 04/13/2005 22:10:00 10.9 0.5 12.6 9.5 10.6 0.6 12.2 9.1 0.4 0 0.4 0.4 44 3 42 305 47 0 48 0 -7.8 0 -7.7 -7.9 04/13/2005 22:20:00 11.1 0.7 12.6 9.1 11 0.8 12.6 8.8 0.4 0 0.4 0.4 44 3 49 305 47 0 47 0 -7.9 0 -7.7 -7.9 04/13/2005 22:30:00 11.2 0.6 12.6 9.5 10.9 0.7 12.6 8.8 0.4 0 0.4 0.4 45 4 46 305 46 0 46 0 -7.9 0 -7.7 -8.2 04/13/2005 22:40:00 11 0.7 13 9.5 10.7 0.7 12.6 8.8 0.4 0 0.4 0.4 45 3 46 305 46 0 46 0 -8.1 0.1 -7.7 -8.2 04/13/2005 22:50:00 10.8 0.7 12.6 8.8 10.5 0.7 12.2 8.8 0.4 0 0.4 0.4 46 4 44 305 45 0 45 0 -8.2 0 -7.9 -8.2 04/13/2005 23:00:00 10.5 0.7 12.2 8.8 10.2 0.7 12.2 8.8 0.4 0 0.4 0.4 45 3 41 305 45 0 45 0 -8.2 0 -7.9 -8.4 04/13/2005 23:10:00 10.8 0.6 12.2 9.1 10.4 0.6 11.8 8.4 0.4 0 0.4 0.4 45 3 48 305 44 0 44 0 -8.3 0 -7.9 -8.4 04/13/2005 23:20:00 10.9 0.7 12.6 9.1 10.5 0.8 12.2 8.4 0.4 0 0.4 0.4 46 3 45 305 43 0 43 0 -8.3 0 -8.2 -8.4 04/13/2005 23:30:00 10.1 0.6 11.8 8.4 9.8 0.6 11.8 8.4 0.4 0 0.4 0.4 46 3 46 305 43 0 43 0 -8.4 0 -8.2 -8.6 04/13/2005 23:40:00 10.1 0.7 12.2 8.4 9.8 0.7 11.8 8 0.4 0 0.4 0.4 41 4 39 305 42 0 42 0 -8.3 0 -7.9 -8.6 04/13/2005 23:50:00 9.8 0.9 12.2 8 9.5 1 11.8 7.6 0.4 0 0.4 0.4 37 5 41 305 41 0 42 0 -8.3 0 -7.9 -8.4 04/14/2005 00:00:00 9.9 0.9 12.2 7.6 9.7 0.9 12.2 7.6 0.4 0 0.4 0.4 36 4 33 305 40 0 40 0 -8.3 0 -7.5 -8.4 04/14/2005 00:10:00 9.7 0.6 11.5 8 9.4 0.6 11.1 8 0.4 0 0.4 0.4 34 3 40 305 40 0 40 0 -8.4 0.1 -8.2 -8.6 04/14/2005 00:20:00 10.6 0.7 12.6 8.8 10.3 0.7 12.2 8.4 0.4 0 0.4 0.4 35 4 38 305 39 0 39 0 -8.5 0 -8.2 -8.6 04/14/2005 00:30:00 11 0.7 13.3 9.5 10.8 0.8 12.6 9.1 0.4 0 0.4 0.4 37 4 35 305 39 0 39 0 -8.5 0 -8.2 -8.6 04/14/2005 00:40:00 11 0.7 12.6 9.1 10.7 0.8 12.6 8.8 0.4 0 0.4 0.4 39 4 36 305 39 0 39 0 -8.5 0 -8.2 -8.8 04/14/2005 00:50:00 10.5 0.6 12.2 8.8 10.2 0.6 12.6 8.8 0.4 0 0.4 0.4 40 4 41 305 38 0 38 0 -8.7 0 -8.4 -8.8 04/14/2005 01:00:00 9.6 0.5 11.1 8.4 9.3 0.5 11.1 8 0.4 0 0.4 0.4 35 3 37 305 38 0 38 0 -8.7 0 -8.4 -9 04/14/2005 01:10:00 9.9 0.7 11.5 7.6 9.7 0.7 11.8 7.2 0.4 0 0.4 0.4 38 4 37 305 37 0 37 0 -8.8 0 -8.6 -9 04/14/2005 01:20:00 10.2 0.6 11.8 8.8 9.9 0.6 11.5 8.4 0.4 0 0.4 0.4 39 4 35 305 37 0 37 0 -8.7 0 -8.6 -8.8 04/14/2005 01:30:00 9.7 0.6 11.5 8.4 9.4 0.6 11.5 7.6 0.4 0 0.4 0.4 35 4 28 305 37 0 36 0 -8.9 0 -8.6 -9.2 04/14/2005 01:40:00 9.9 0.6 11.5 8.8 9.7 0.7 11.5 8.4 0.4 0 0.4 0.4 32 3 27 305 36 0 36 0 -9 0 -8.8 -9.2 04/14/2005 01:50:00 10.3 0.5 11.5 9.1 10 0.5 11.5 8.4 0.4 0 0.4 0.4 32 3 35 305 36 0 36 0 -9 0 -8.8 -9.2 04/14/2005 02:00:00 10.6 0.6 12.2 8.8 10.3 0.6 12.2 8.4 0.4 0 0.4 0.4 32 3 30 305 35 0 35 0 -9.1 0 -8.8 -9.2 04/14/2005 02:10:00 10.7 0.6 11.8 9.1 10.4 0.6 11.8 8.8 0.4 0 0.4 0.4 32 3 29 305 35 0 35 0 -9.1 0 -8.8 -9.2 04/14/2005 02:20:00 10.8 0.6 12.6 9.1 10.5 0.7 12.2 9.1 0.4 0 0.4 0.4 31 4 29 305 35 0 34 0 -9.3 0 -9 -9.2 04/14/2005 02:30:00 10.9 0.6 13 9.5 10.6 0.7 12.6 9.1 0.4 0 0.4 0.4 32 4 23 305 34 0 34 0 -9.2 0 -9 -9.2 04/14/2005 02:40:00 10.7 0.7 12.6 8.8 10.4 0.8 12.2 8.8 0.4 0 0.4 0.4 33 4 32 305 34 0 34 0 -9.3 0 -9 -9.4 04/14/2005 02:50:00 10.8 0.6 12.2 8.8 10.6 0.7 12.2 8.8 0.4 0 0.4 0.4 33 3 32 305 34 0 34 0 -9.3 0 -9 -9.4 04/14/2005 03:00:00 11.3 0.8 13 9.1 10.9 0.8 12.6 8.8 0.4 0 0.4 0.4 34 4 33 305 33 0 33 0 -9.4 0 -9.2 -9.6 04/14/2005 03:10:00 11.2 0.7 12.6 9.1 10.9 0.7 12.6 9.1 0.4 0 0.4 0.4 37 4 34 305 33 0 33 0 -9.4 0 -9.2 -9.6 04/14/2005 03:20:00 10.9 0.7 13 9.1 10.6 0.7 12.2 8.8 0.4 0 0.4 0.4 37 4 42 305 33 0 33 0 -9.5 0 -9.2 -9.6 04/14/2005 03:30:00 11 0.8 13 9.1 10.7 0.9 13.3 9.1 0.4 0 0.4 0.4 38 4 34 305 32 0 32 0 -9.5 0 -9.2 -9.8 04/14/2005 03:40:00 10.6 0.8 12.6 8.4 10.2 0.8 12.2 8.4 0.4 0 0.4 0.4 38 4 39 305 32 0 32 0 -9.7 0.1 -9.4 -9.8 04/14/2005 03:50:00 10.4 0.8 13.3 8.8 10 0.8 13 8.4 0.4 0 0.4 0.4 40 4 36 305 32 0 32 0 -9.8 0 -9.4 -9.8 04/14/2005 04:00:00 10.8 0.6 13 9.5 10.5 0.7 12.2 9.1 0.4 0 0.4 0.4 42 4 39 305 31 0 32 0 -9.7 0.1 -9.4 -9.8 04/14/2005 04:10:00 11 0.6 12.6 9.5 10.7 0.7 12.2 8.8 0.4 0 0.4 0.4 42 4 38 305 31 0 31 0 -9.7 0 -9.4 -9.8 04/14/2005 04:20:00 11 0.5 12.2 9.9 10.8 0.6 12.6 9.1 0.4 0 0.4 0.4 43 3 45 305 31 0 31 0 -9.8 0 -9.6 -10 04/14/2005 04:30:00 10.9 0.6 12.6 9.5 10.6 0.6 12.6 9.1 0.4 0 0.4 0.4 45 4 40 305 31 0 31 0 -9.8 0 -9.6 -10 04/14/2005 04:40:00 10.7 0.6 12.2 9.5 10.4 0.6 12.2 9.1 0.4 0 0.4 0.4 45 3 43 305 30 0 31 0 -9.9 0 -9.6 -10 04/14/2005 04:50:00 10.9 0.5 12.2 9.5 10.6 0.5 11.8 9.1 0.4 0 0.4 0.4 46 3 41 305 30 0 30 0 -9.9 0 -9.6 -10 04/14/2005 05:00:00 11 0.7 13.3 9.5 10.7 0.7 13 9.1 0.4 0 0.4 0.4 45 3 45 305 30 0 30 0 -10 0 -9.6 -10.2 04/14/2005 05:10:00 11.5 0.7 14.5 9.9 11.1 0.7 13.3 9.5 0.4 0 0.4 0.4 43 5 43 305 30 0 29 0 -9.8 0 -9.6 -10 04/14/2005 05:20:00 11.1 0.7 13 9.5 10.8 0.7 12.6 9.1 0.4 0 0.4 0.4 44 4 36 305 29 0 29 0 -9.9 0 -9.6 -10 04/14/2005 05:30:00 11.3 0.6 13 9.5 11 0.7 13.3 9.1 0.4 0 0.4 0.4 42 4 39 305 29 0 29 0 -9.8 0 -9.4 -10 04/14/2005 05:40:00 11 0.7 12.6 9.1 10.7 0.6 12.2 8.8 0.4 0 0.4 0.4 43 3 43 305 29 0 29 0 -9.9 0 -9.8 -10 04/14/2005 05:50:00 11.2 0.7 13 9.5 10.8 0.8 13 9.1 0.4 0 0.4 0.4 43 4 38 305 29 0 29 0 -9.9 0 -9.8 -10 04/14/2005 06:00:00 11.6 0.7 13.7 9.9 11.3 0.7 13.3 9.5 0.4 0 0.4 0.4 43 4 37 305 29 0 29 0 -9.9 0 -9.6 -10 04/14/2005 06:10:00 10.7 0.5 12.2 9.5 10.4 0.6 11.8 8.8 0.4 0 0.4 0.4 43 3 42 305 29 0 29 0 -9.9 0 -9.8 -10 04/14/2005 06:20:00 10.2 0.6 11.8 8.8 9.9 0.6 11.5 8.4 0.4 0 0.4 0.4 42 3 39 305 29 0 29 0 -10 0 -9.8 -10 04/14/2005 06:30:00 9.8 0.4 11.1 8.8 9.6 0.4 11.1 8.4 0.4 0 0.4 0.4 43 3 40 305 28 0 28 0 -10 0 -9.8 -10 04/14/2005 06:40:00 9.8 0.5 11.1 8.8 9.6 0.5 11.1 8.4 0.4 0 0.4 0.4 42 3 46 305 28 0 28 0 -10 0 -9.8 -10 04/14/2005 06:50:00 9.8 0.6 11.8 8.4 9.5 0.5 11.1 8 0.4 0 0.4 0.4 39 4 35 305 28 0 28 0 -9.9 0 -9.8 -10 04/14/2005 07:00:00 11.1 0.7 13 9.5 10.8 0.7 12.6 9.1 0.4 0 0.4 0.4 36 4 34 305 28 0 28 0 -9.9 0 -9.8 -10 04/14/2005 07:10:00 11.4 0.8 13 9.1 11.1 0.9 13 9.1 0.4 0 0.4 0.4 35 4 33 305 28 0 28 0 -9.8 0 -9.6 -10 04/14/2005 07:20:00 11 0.7 13 9.1 10.7 0.8 13 8.8 0.4 0 0.4 0.4 37 4 29 305 28 0 28 0 -9.8 0 -9.6 -10 04/14/2005 07:30:00 11.2 0.7 13 9.1 11 0.9 13.3 8.8 0.4 0 0.4 0.4 39 4 35 305 28 0 28 0 -9.8 0 -9.6 -10 04/14/2005 07:40:00 11.7 0.8 13.7 9.9 11.4 0.8 13.7 9.5 0.4 0 0.4 0.4 41 5 44 305 28 0 28 0 -9.8 0 -9.6 -10 04/14/2005 07:50:00 11.9 0.8 13.7 9.5 11.6 0.8 13.7 9.1 0.4 0 0.4 0.4 40 4 45 305 28 0 28 0 -9.8 0 -9.4 -10 04/14/2005 08:00:00 12.1 0.8 14.1 9.9 11.9 0.8 13.7 9.5 0.4 0 0.4 0.4 40 4 34 305 29 0 28 0 -9.8 0 -9.6 -10 04/14/2005 08:10:00 11.8 0.8 13.7 9.5 11.7 0.9 13.7 9.5 0.4 0 0.4 0.4 40 4 46 305 29 0 29 0 -9.7 0.1 -9.4 -9.8 04/14/2005 08:20:00 11.2 0.8 13 9.1 10.9 0.8 13 9.1 0.4 0 0.4 0.4 39 4 42 305 29 0 29 0 -9.7 0.1 -9.4 -9.8 04/14/2005 08:30:00 10.6 1 12.6 8.4 10.4 0.9 12.2 8.4 0.4 0 0.4 0.4 39 4 39 305 29 0 29 0 -9.7 0.1 -9.2 -9.8 04/14/2005 08:40:00 11.1 1 13.7 8.8 11 1.1 13.3 8.4 0.4 0 0.4 0.4 38 4 37 305 30 0 29 0 -9.6 0.1 -9.2 -9.8 04/14/2005 08:50:00 10.9 1 13.3 8.8 10.7 1.2 13 8 0.4 0 0.4 0.4 38 5 33 305 30 0 30 0 -9.6 0.1 -9.2 -9.8 04/14/2005 09:00:00 11.2 0.9 13.7 9.1 11.1 0.9 13.3 8.8 0.4 0 0.4 0.4 37 5 34 305 31 0 31 0 -9.7 0 -9.2 -9.8 04/14/2005 09:10:00 11.7 0.8 13.7 9.5 11.5 0.9 13.3 9.5 0.4 0 0.4 0.4 39 4 39 305 31 0 31 0 -9.7 0 -9.2 -9.8 04/14/2005 09:20:00 11.6 0.8 13.3 9.5 11.5 0.9 13.7 9.1 0.4 0 0.4 0.4 39 5 42 305 31 0 31 0 -9.7 0.1 -9.2 -9.8 04/14/2005 09:30:00 12 0.8 14.5 9.5 11.8 0.9 13.7 9.5 0.4 0 0.4 0.4 39 4 37 305 32 0 32 0 -9.7 0 -9.4 -9.8 04/14/2005 09:40:00 11.5 0.8 13.3 9.1 11.3 0.9 13.7 8.8 0.4 0 0.4 0.4 37 4 31 305 32 0 32 0 -9.6 0 -9.2 -9.8 04/14/2005 09:50:00 12.3 0.9 14.5 9.9 12.2 1 14.5 9.5 0.4 0 0.4 0.4 38 4 39 305 33 0 33 0 -9.5 0 -9.2 -9.6 04/14/2005 10:00:00 11.6 0.8 13.3 8.8 11.5 1 13.3 8.4 0.4 0 0.4 0.4 38 5 39 305 33 0 33 0 -9.5 0 -9.2 -9.6 04/14/2005 10:10:00 11.9 0.8 14.1 9.5 11.8 0.9 13.7 9.1 0.4 0 0.4 0.4 39 4 36 305 34 0 34 0 -9.5 0 -9.2 -9.6 04/14/2005 10:20:00 11.3 0.8 13 8.8 11.1 0.9 13 8.8 0.4 0 0.4 0.4 40 5 37 305 35 0 35 0 -9.4 0 -9 -9.6 04/14/2005 10:30:00 11.3 0.7 13 9.1 11.1 0.8 13 9.1 0.4 0 0.4 0.4 42 4 37 305 36 0 35 0 -9.4 0 -9 -9.4 04/14/2005 10:40:00 11.2 0.8 13 9.1 11.1 0.8 13 9.1 0.4 0 0.4 0.4 42 4 42 305 36 0 36 0 -9.3 0 -9 -9.6 04/14/2005 10:50:00 11.7 0.7 13 9.5 11.5 0.8 13.3 9.1 0.4 0 0.4 0.4 41 4 39 305 37 0 37 0 -9.3 0 -8.8 -9.4 04/14/2005 11:00:00 11.4 0.6 13.3 9.9 11.3 0.7 13 9.5 0.4 0 0.4 0.4 41 4 39 305 38 0 38 0 -9.2 0 -9 -9.2 04/14/2005 11:10:00 11.7 0.8 13 9.1 11.6 0.9 13.3 9.1 0.4 0 0.4 0.4 41 3 41 305 39 0 39 0 -9.1 0 -8.8 -9.2 04/14/2005 11:20:00 11.8 0.6 13 9.9 11.7 0.7 13 9.9 0.4 0 0.4 0.4 42 3 44 305 40 0 39 0 -9 0 -8.8 -9.2 04/14/2005 11:30:00 11.7 0.7 13 9.1 11.6 0.8 13 8.8 0.4 0 0.4 0.4 41 4 45 305 40 0 40 0 -9 0 -8.8 -9.2 04/14/2005 11:40:00 11.3 0.8 13.3 8.8 11.1 0.9 13 8.8 0.4 0 0.4 0.4 41 3 39 305 41 0 41 0 -8.9 0 -8.8 -9 04/14/2005 11:50:00 11 0.7 12.6 9.1 10.8 0.8 13 8.8 0.4 0 0.4 0.4 42 4 45 305 42 0 42 0 -8.8 0 -8.6 -9 04/14/2005 12:00:00 10.4 0.6 11.8 8.4 10.3 0.6 11.8 8.4 0.4 0 0.4 0.4 39 4 45 305 43 0 43 0 -8.7 0 -8.4 -8.8 04/14/2005 12:10:00 11.6 0.8 13.3 9.5 11.2 0.9 13.3 8.8 0.4 0 0.4 0.4 34 4 30 305 44 0 44 0 -8.6 0 -8.4 -8.8 04/14/2005 12:20:00 11.3 0.9 13 8.8 11.2 0.9 12.6 8.4 0.4 0 0.4 0.4 37 3 37 305 45 0 44 0 -8.5 0 -8.2 -8.8 04/14/2005 12:30:00 11.1 1 13 8.4 11 1 12.6 8 0.4 0 0.4 0.4 36 4 35 305 45 0 45 0 -8.4 0 -8.2 -8.6 04/14/2005 12:40:00 11 0.7 12.6 8.4 10.9 0.8 12.6 8.4 0.4 0 0.4 0.4 35 4 41 305 46 0 46 0 -8.4 0 -7.9 -8.4 04/14/2005 12:50:00 11.2 0.7 12.6 9.1 10.9 0.8 12.6 8.8 0.4 0 0.4 0.4 34 4 37 305 46 0 46 0 -8.4 0 -8.2 -8.4 04/14/2005 13:00:00 11.3 0.6 12.6 9.1 11.1 0.7 12.6 9.1 0.4 0 0.4 0.4 32 3 31 305 47 0 46 0 -8.3 0 -8.2 -8.4 04/14/2005 13:10:00 10.8 0.9 13 8.4 10.7 0.9 13 8 0.4 0 0.4 0.4 33 4 30 305 47 0 47 0 -8.2 0 -7.9 -8.4 04/14/2005 13:20:00 10.9 0.8 12.2 8.4 10.7 0.8 12.2 8.4 0.4 0 0.4 0.4 32 4 31 305 48 0 48 0 -8.2 0 -7.9 -8.4 04/14/2005 13:30:00 11.3 0.7 13 8.8 11.1 0.8 13 8.8 0.4 0 0.4 0.4 31 4 28 305 48 0 48 0 -8.2 0 -7.9 -8.4 04/14/2005 13:40:00 11.2 0.7 12.6 8.8 11 0.8 12.6 8 0.4 0 0.4 0.4 34 4 30 305 48 0 48 0 -8.2 0 -7.9 -8.2 04/14/2005 13:50:00 11.2 1 13.3 8.8 10.9 1 13.3 8.4 0.4 0 0.4 0.4 32 3 34 305 49 0 49 0 -8.1 0 -7.7 -8.2 04/14/2005 14:00:00 10.5 0.9 12.6 8 10.4 0.9 13 8 0.4 0 0.4 0.4 36 4 32 305 49 0 49 0 -7.9 0 -7.7 -8.2 04/14/2005 14:10:00 10.9 0.6 12.2 9.1 10.6 0.7 12.2 8.8 0.4 0 0.4 0.4 34 3 34 305 50 0 50 0 -7.9 0 -7.7 -7.9 04/14/2005 14:20:00 10.5 0.8 11.8 7.6 10.4 0.9 11.8 7.2 0.4 0 0.4 0.4 35 4 36 305 50 0 50 0 -7.8 0 -7.5 -7.9 04/14/2005 14:30:00 10.6 1 12.6 8.4 10.4 1 12.6 8 0.4 0 0.4 0.4 33 4 33 305 50 0 51 0 -7.9 0 -7.5 -8.2 04/14/2005 14:40:00 11.1 0.7 12.6 9.1 11 0.7 12.6 8.4 0.4 0 0.4 0.4 32 4 30 305 51 0 51 0 -7.9 0 -7.7 -8.2 04/14/2005 14:50:00 11 0.7 13 9.1 10.8 0.8 13 8.8 0.4 0 0.4 0.4 33 4 36 305 51 0 51 0 -7.8 0 -7.7 -7.9 04/14/2005 15:00:00 10.5 0.9 12.6 8.4 10.3 0.9 12.6 7.6 0.4 0 0.4 0.4 32 4 32 305 51 0 51 0 -7.7 0 -7.7 -7.9 04/14/2005 15:10:00 11.1 0.8 13 8.8 10.9 0.8 13 8.8 0.4 0 0.4 0.4 35 3 38 305 52 0 52 0 -7.7 0 -7.7 -7.9 04/14/2005 15:20:00 11.1 0.8 12.6 8.8 10.9 0.8 13 8 0.4 0 0.4 0.4 38 4 33 305 52 0 52 0 -7.7 0 -7.5 -7.9 04/14/2005 15:30:00 10.7 0.7 12.2 8.8 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 36 5 37 305 52 0 52 0 -7.7 0 -7.5 -7.9 04/14/2005 15:40:00 10.3 0.8 11.8 8 10.2 0.8 12.2 7.6 0.4 0 0.4 0.4 34 5 43 305 52 0 52 0 -7.7 0 -7.5 -7.9 04/14/2005 15:50:00 10.7 0.8 12.2 8.8 10.6 0.8 12.6 8.8 0.4 0 0.4 0.4 34 4 32 305 52 0 52 0 -7.7 0 -7.7 -7.9 04/14/2005 16:00:00 11.4 0.7 13 9.1 11.2 0.8 13 8.8 0.4 0 0.4 0.4 33 3 31 305 52 0 52 0 -7.7 0 -7.7 -7.9 04/14/2005 16:10:00 11.2 0.6 12.6 9.5 11 0.7 12.6 9.1 0.4 0 0.4 0.4 33 4 35 305 52 0 52 0 -7.7 0 -7.7 -7.9 04/14/2005 16:20:00 11 0.9 12.6 8.4 10.8 0.9 13 8.8 0.4 0 0.4 0.4 35 5 33 305 52 0 52 0 -7.7 0 -7.5 -7.9 04/14/2005 16:30:00 10.9 0.7 12.2 8.8 10.7 0.8 12.6 8.4 0.4 0 0.4 0.4 31 4 33 305 53 0 53 0 -7.7 0 -7.5 -7.7 04/14/2005 16:40:00 11 0.8 12.2 8.4 10.8 0.8 12.6 8.4 0.4 0 0.4 0.4 32 3 31 305 53 0 53 0 -7.6 0 -7.3 -7.7 04/14/2005 16:50:00 10.9 0.7 12.6 8.8 10.7 0.7 12.2 9.1 0.4 0 0.4 0.4 31 3 32 305 53 0 53 0 -7.5 0 -7.3 -7.7 04/14/2005 17:00:00 10.8 0.9 12.6 8.4 10.6 0.9 12.2 8 0.4 0 0.4 0.4 32 5 27 305 54 0 53 0 -7.5 0 -7.3 -7.7 04/14/2005 17:10:00 10.9 0.7 12.6 9.1 10.7 0.6 12.2 8.8 0.4 0 0.4 0.4 31 4 33 305 54 0 54 0 -7.5 0 -7.3 -7.7 04/14/2005 17:20:00 10.5 0.7 11.8 8.8 10.4 0.7 11.8 8.4 0.4 0 0.4 0.4 33 4 36 305 54 0 54 0 -7.5 0 -7.3 -7.7 04/14/2005 17:30:00 9.7 0.8 11.5 7.2 9.5 0.8 11.5 7.6 0.4 0 0.4 0.4 29 4 32 305 55 0 54 0 -7.4 0 -7.1 -7.7 04/14/2005 17:40:00 9.5 0.9 11.5 7.2 9.4 0.9 11.5 6.8 0.4 0 0.4 0.4 30 6 22 305 55 0 55 0 -7.4 0 -7.1 -7.5 04/14/2005 17:50:00 10.1 0.9 11.8 8 10 0.9 11.8 8 0.4 0 0.4 0.4 33 6 37 305 55 0 55 0 -7.3 0 -7.1 -7.5 04/14/2005 18:00:00 10.1 0.8 11.8 7.6 9.9 0.8 11.8 7.6 0.4 0 0.4 0.4 38 5 37 305 55 0 55 0 -7.4 0 -7.1 -7.7 04/14/2005 18:10:00 10.1 0.7 12.2 8 10 0.8 11.8 8 0.4 0 0.4 0.4 38 5 47 305 54 0 54 0 -7.5 0 -7.3 -7.7 04/14/2005 18:20:00 10.6 0.7 11.8 8.8 10.5 0.7 11.8 8 0.4 0 0.4 0.4 39 4 40 305 54 0 54 0 -7.5 0.1 -7.3 -7.7 04/14/2005 18:30:00 9.3 0.8 11.5 7.6 9.1 0.8 11.5 7.2 0.4 0 0.4 0.4 35 6 30 305 54 0 54 0 -7.4 0 -7.1 -7.7 04/14/2005 18:40:00 10.1 0.9 11.8 7.6 9.9 0.9 11.8 7.2 0.4 0 0.4 0.4 32 4 34 305 54 0 54 0 -7.5 0.1 -7.3 -7.7 04/14/2005 18:50:00 10.2 0.9 11.8 8 10 1 12.2 7.2 0.4 0 0.4 0.4 36 5 37 305 54 0 54 0 -7.6 0 -7.3 -7.7 04/14/2005 19:00:00 9.8 0.7 11.8 8 9.7 0.7 11.8 8 0.4 0 0.4 0.4 38 4 35 305 53 0 53 0 -7.7 0 -7.5 -7.9 04/14/2005 19:10:00 9.6 0.9 11.5 7.2 9.5 0.9 11.1 7.2 0.4 0 0.4 0.4 38 6 37 305 53 0 53 0 -7.8 0 -7.7 -7.9 04/14/2005 19:20:00 9.2 0.7 10.7 7.2 9.1 0.7 10.7 7.6 0.4 0 0.4 0.4 38 5 32 305 53 0 53 0 -7.8 0 -7.7 -7.9 04/14/2005 19:30:00 9.1 0.7 11.1 7.2 8.9 0.7 10.7 7.2 0.4 0 0.4 0.4 35 4 33 305 52 0 52 0 -8 0 -7.7 -8.2 04/14/2005 19:40:00 9.4 0.8 11.5 7.2 9.1 0.9 11.1 6.8 0.4 0 0.4 0.4 37 4 31 305 52 0 52 0 -8 0 -7.7 -8.2 04/14/2005 19:50:00 9.6 0.8 11.1 7.6 9.5 0.8 11.1 7.6 0.4 0 0.4 0.4 40 5 48 305 51 0 52 0 -8 0 -7.7 -8.2 04/14/2005 20:00:00 9.5 0.8 11.1 7.2 9.3 0.8 11.5 6.8 0.4 0 0.4 0.4 43 5 40 305 51 0 51 0 -8.2 0 -7.9 -8.2 04/14/2005 20:10:00 9.4 0.8 11.1 7.2 9.2 0.9 11.1 7.2 0.4 0 0.4 0.4 44 5 42 305 50 0 50 0 -8.3 0 -8.2 -8.4 04/14/2005 20:20:00 9 0.8 11.5 6.8 8.9 0.8 11.1 6.5 0.4 0 0.4 0.4 45 4 42 305 50 0 50 0 -8.4 0 -8.2 -8.6 04/14/2005 20:30:00 8.9 0.8 10.7 6.5 8.7 0.8 10.3 6.5 0.4 0 0.4 0.4 45 4 45 305 49 0 49 0 -8.6 0 -8.4 -8.8 04/14/2005 20:40:00 8.6 0.6 9.9 7.2 8.4 0.6 9.9 7.2 0.4 0 0.4 0.4 44 4 42 305 48 0 48 0 -8.6 0 -8.4 -8.8 04/14/2005 20:50:00 8.4 0.7 9.9 6.5 8.2 0.7 10.3 5.7 0.4 0 0.4 0.4 45 4 47 305 47 0 47 0 -8.8 0 -8.6 -9 04/14/2005 21:00:00 8.5 0.7 10.7 6.8 8.4 0.7 10.3 6.8 0.4 0 0.4 0.4 41 5 37 305 46 0 46 0 -8.9 0 -8.8 -9.2 04/14/2005 21:10:00 9 0.6 10.3 7.6 8.8 0.6 10.3 7.6 0.4 0 0.4 0.4 38 4 31 305 45 0 45 0 -9.1 0 -8.8 -9.2 04/14/2005 21:20:00 9.1 0.7 11.1 7.2 8.9 0.7 11.1 7.2 0.4 0 0.4 0.4 36 4 33 305 44 0 44 0 -9.2 0 -9 -9.2 04/14/2005 21:30:00 8.3 0.6 9.5 6.5 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 38 4 35 305 43 0 43 0 -9.3 0 -9 -9.4 04/14/2005 21:40:00 8.7 0.6 9.9 7.2 8.5 0.6 9.5 6.8 0.4 0 0.4 0.4 41 3 42 305 41 2 42 0 -9.3 0 -9 -9.4 04/14/2005 21:50:00 8.7 0.4 9.5 7.2 8.6 0.5 9.5 6.8 0.4 0 0.4 0.4 42 3 44 305 36 1 36 0 -9.4 0 -9.2 -9.6 04/14/2005 22:00:00 7.7 0.6 9.1 6.1 7.4 0.6 8.8 6.1 0.4 0 0.4 0.4 43 4 46 305 34 0 35 0 -9.5 0.1 -9.2 -9.6 04/14/2005 22:10:00 7.8 0.6 9.5 6.5 7.6 0.6 9.1 6.5 0.4 0 0.4 0.4 42 5 40 305 33 0 33 0 -9.6 0 -9.4 -9.8 04/14/2005 22:20:00 8.3 0.7 9.9 6.5 8.1 0.7 9.9 6.5 0.4 0 0.4 0.4 39 4 39 305 32 0 32 0 -9.6 0 -9.4 -9.6 04/14/2005 22:30:00 8.8 0.5 9.9 7.6 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 40 3 41 305 31 0 32 0 -9.7 0 -9.4 -9.8 04/14/2005 22:40:00 8.3 0.5 9.9 7.2 8.1 0.6 9.9 6.8 0.4 0 0.4 0.4 40 3 37 305 31 0 31 0 -9.7 0 -9.4 -9.8 04/14/2005 22:50:00 8.5 0.5 9.5 7.2 8.2 0.5 9.5 6.8 0.4 0 0.4 0.4 40 3 43 305 30 0 30 0 -9.8 0 -9.6 -10 04/14/2005 23:00:00 8.8 0.7 10.3 6.8 8.6 0.7 9.9 6.5 0.4 0 0.4 0.4 40 4 41 305 30 0 30 0 -9.7 0 -9.4 -9.8 04/14/2005 23:10:00 8 0.8 9.5 6.1 7.9 1 9.5 6.1 0.4 0 0.4 0.4 44 4 44 305 30 0 29 0 -9.8 0 -9.6 -10 04/14/2005 23:20:00 7.7 0.6 9.5 6.1 7.5 0.6 9.5 6.1 0.4 0 0.4 0.4 41 5 39 305 29 0 29 0 -9.8 0 -9.6 -10 04/14/2005 23:30:00 8.7 0.6 9.9 6.8 8.5 0.7 9.5 6.1 0.4 0 0.4 0.4 37 4 37 305 29 0 29 0 -9.7 0 -9.6 -9.8 04/14/2005 23:40:00 8.7 0.7 10.3 6.5 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 37 4 43 305 29 0 29 0 -9.7 0 -9.4 -9.8 04/14/2005 23:50:00 8.9 0.6 10.3 7.6 8.6 0.6 10.3 6.8 0.4 0 0.4 0.4 39 4 36 305 29 0 29 0 -9.8 0 -9.6 -9.8 04/15/2005 00:00:00 9 0.6 10.3 7.2 8.8 0.7 10.3 6.8 0.4 0 0.4 0.4 39 3 40 305 29 0 29 0 -9.8 0 -9.2 -9.8 04/15/2005 00:10:00 8.9 0.5 9.9 7.2 8.7 0.5 10.3 7.2 0.4 0 0.4 0.4 35 3 38 305 29 0 29 0 -9.8 0 -9.6 -10 04/15/2005 00:20:00 8.8 0.6 10.3 6.8 8.7 0.7 9.9 6.8 0.4 0 0.4 0.4 37 3 35 305 29 0 29 0 -9.8 0 -9.6 -10 04/15/2005 00:30:00 8.5 0.5 9.5 6.8 8.3 0.6 9.5 6.1 0.4 0 0.4 0.4 38 4 37 305 29 0 29 0 -9.8 0 -9.6 -10 04/15/2005 00:40:00 8.9 0.5 9.9 6.8 8.8 0.7 9.9 6.5 0.4 0 0.4 0.4 37 4 34 305 29 0 29 0 -9.9 0 -9.6 -10 04/15/2005 00:50:00 8.9 0.6 10.3 7.2 8.7 0.6 10.3 7.2 0.4 0 0.4 0.4 38 4 42 305 29 0 28 0 -10 0 -9.8 -10.2 04/15/2005 01:00:00 9 0.5 10.3 7.6 8.9 0.5 10.3 7.6 0.4 0 0.4 0.4 38 3 37 305 28 0 28 0 -10 0 -9.8 -10.2 04/15/2005 01:10:00 9.3 0.5 10.7 7.6 9.1 0.6 10.3 7.2 0.4 0 0.4 0.4 37 3 35 305 28 0 28 0 -10.1 0 -9.8 -10.2 04/15/2005 01:20:00 9.7 0.6 11.1 7.6 9.5 0.6 11.1 8 0.4 0 0.4 0.4 35 3 37 305 28 0 28 0 -10.1 0 -9.8 -10.2 04/15/2005 01:30:00 9.6 0.6 11.1 8 9.4 0.6 10.7 7.6 0.4 0 0.4 0.4 38 4 37 305 28 0 28 0 -10.2 0 -9.8 -10.4 04/15/2005 01:40:00 9.1 0.8 11.1 7.2 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 38 4 40 305 28 0 28 0 -10.2 0 -10 -10.4 04/15/2005 01:50:00 9.4 0.7 10.7 7.6 9.2 0.7 10.7 6.8 0.4 0 0.4 0.4 35 4 39 305 27 0 27 0 -10.3 0 -10 -10.4 04/15/2005 02:00:00 9.1 0.6 10.7 6.8 9 0.7 10.7 6.8 0.4 0 0.4 0.4 37 5 34 305 27 0 27 0 -10.3 0 -10 -10.4 04/15/2005 02:10:00 8.9 0.5 10.3 7.6 8.8 0.6 9.9 7.2 0.4 0 0.4 0.4 40 4 47 305 27 0 27 0 -10.3 0 -10 -10.4 04/15/2005 02:20:00 9.4 0.6 10.7 8 9.2 0.7 10.7 7.6 0.4 0 0.4 0.4 38 4 42 305 27 0 27 0 -10.4 0 -10 -10.7 04/15/2005 02:30:00 9.4 0.6 10.7 7.6 9.2 0.7 10.7 7.2 0.4 0 0.4 0.4 36 5 41 305 27 0 27 0 -10.4 0 -10.2 -10.4 04/15/2005 02:40:00 9.3 0.8 11.1 6.8 9.2 0.7 10.7 6.5 0.4 0 0.4 0.4 40 4 44 305 26 0 26 0 -10.4 0 -10 -10.4 04/15/2005 02:50:00 9 0.6 10.7 7.2 8.8 0.7 10.3 6.8 0.4 0 0.4 0.4 41 4 35 305 26 0 26 0 -10.4 0 -10.2 -10.4 04/15/2005 03:00:00 8.8 0.6 10.3 6.5 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 41 4 43 305 26 0 26 0 -10.4 0 -10.2 -10.7 04/15/2005 03:10:00 8.7 0.7 10.7 6.8 8.5 0.7 10.3 6.5 0.4 0 0.4 0.4 37 4 39 305 26 0 26 0 -10.5 0 -10.2 -10.7 04/15/2005 03:20:00 8.3 0.8 9.9 6.5 8.2 0.8 9.9 6.5 0.4 0 0.4 0.4 34 5 33 305 26 0 26 0 -10.4 0 -10.2 -10.7 04/15/2005 03:30:00 9.2 0.5 10.7 7.6 9.1 0.6 10.7 7.2 0.4 0 0.4 0.4 32 4 29 305 26 0 26 0 -10.5 0 -10.4 -10.9 04/15/2005 03:40:00 9 0.6 10.3 6.8 8.8 0.6 10.3 6.8 0.4 0 0.4 0.4 36 4 33 305 26 0 25 0 -10.6 0 -10.4 -10.9 04/15/2005 03:50:00 9.3 0.7 10.7 7.2 9.1 0.8 10.7 6.8 0.4 0 0.4 0.4 35 3 37 305 25 0 26 0 -10.6 0 -10.4 -10.9 04/15/2005 04:00:00 8.3 0.9 9.9 6.1 8.2 0.9 9.9 6.1 0.4 0 0.4 0.4 31 5 40 305 25 0 25 0 -10.5 0 -10.4 -10.9 04/15/2005 04:10:00 8.3 0.8 9.9 6.5 8 0.8 9.5 6.5 0.4 0 0.4 0.4 34 5 35 305 25 0 25 0 -10.6 0 -10.4 -10.9 04/15/2005 04:20:00 8.3 0.7 9.5 6.1 8.1 0.7 9.5 6.1 0.4 0 0.4 0.4 29 4 31 305 25 0 25 0 -10.7 0 -10.4 -10.9 04/15/2005 04:30:00 7.8 0.6 9.1 6.1 7.6 0.7 9.1 5.7 0.4 0 0.4 0.4 31 4 26 305 25 0 25 0 -10.7 0 -10.4 -10.9 04/15/2005 04:40:00 8.2 0.7 9.9 6.5 8.1 0.7 9.5 6.1 0.4 0 0.4 0.4 33 5 24 305 25 0 25 0 -10.7 0 -10.4 -10.9 04/15/2005 04:50:00 7.9 0.7 9.5 6.1 7.8 0.7 9.5 6.1 0.4 0 0.4 0.4 35 4 43 305 25 0 25 0 -10.7 0 -10.4 -10.9 04/15/2005 05:00:00 7.8 0.6 9.1 6.1 7.7 0.7 9.5 6.1 0.4 0 0.4 0.4 33 5 37 305 25 0 25 0 -10.7 0 -10.4 -10.9 04/15/2005 05:10:00 8.3 0.6 9.5 6.5 8.1 0.6 9.1 6.5 0.4 0 0.4 0.4 39 4 38 305 25 0 25 0 -10.8 0 -10.7 -10.9 04/15/2005 05:20:00 8.1 0.6 9.1 6.5 8.1 0.6 9.1 6.1 0.4 0 0.4 0.4 39 3 41 305 25 0 25 0 -10.8 0 -10.7 -10.9 04/15/2005 05:30:00 8.2 0.6 9.5 6.5 8.1 0.7 9.5 6.5 0.4 0 0.4 0.4 38 4 35 305 24 0 24 0 -10.8 0 -10.7 -10.9 04/15/2005 05:40:00 7.9 0.6 9.5 6.1 7.7 0.7 9.1 6.1 0.4 0 0.4 0.4 39 6 33 305 24 0 24 0 -10.9 0 -10.7 -10.9 04/15/2005 05:50:00 7.3 0.5 8.8 6.1 7.2 0.6 8.4 5.7 0.4 0 0.4 0.4 47 4 49 305 24 0 24 0 -11 0 -10.9 -11.3 04/15/2005 06:00:00 7.3 0.6 8.8 5.7 7.2 0.6 8.8 5.7 0.4 0 0.4 0.4 46 5 45 305 24 0 24 0 -11 0 -10.9 -11.3 04/15/2005 06:10:00 7.5 0.6 8.8 6.1 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 48 5 49 305 24 0 24 0 -11 0 -10.9 -11.3 04/15/2005 06:20:00 7.4 0.7 8.8 5.7 7.4 0.7 8.8 5.7 0.4 0 0.4 0.4 50 4 50 305 24 0 24 0 -11.1 0 -10.9 -11.3 04/15/2005 06:30:00 7.6 0.5 8.8 6.5 7.6 0.5 8.8 6.1 0.4 0 0.4 0.4 50 4 50 305 23 0 24 0 -11.1 0 -10.9 -11.3 04/15/2005 06:40:00 7.4 0.5 8.8 5.7 7.3 0.6 8.8 6.1 0.4 0 0.4 0.4 49 4 56 305 23 0 24 0 -11.1 0 -10.9 -11.3 04/15/2005 06:50:00 7.1 0.6 8.4 5.7 7 0.7 8.8 5.3 0.4 0 0.4 0.4 48 5 50 305 23 0 23 0 -11.2 0 -10.9 -11.3 04/15/2005 07:00:00 7.4 0.7 8.8 5.3 7.4 0.8 8.8 5.3 0.4 0 0.4 0.4 49 4 55 305 23 0 23 0 -11.2 0 -10.9 -11.3 04/15/2005 07:10:00 7.4 0.4 8.4 6.1 7.4 0.5 8.4 6.1 0.4 0 0.4 0.4 50 4 38 305 23 0 23 0 -11.2 0 -10.9 -11.5 04/15/2005 07:20:00 7.2 0.5 9.1 5.7 7.1 0.6 8.8 5.7 0.4 0 0.4 0.4 48 4 50 305 23 0 23 0 -11.3 0 -10.9 -11.5 04/15/2005 07:30:00 7.4 0.4 8.4 6.1 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 46 4 50 305 23 0 23 0 -11.3 0 -10.9 -11.5 04/15/2005 07:40:00 7.4 0.5 8.8 5.7 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 48 6 58 305 23 0 23 0 -11.3 0.1 -10.9 -11.5 04/15/2005 07:50:00 7.5 0.5 8.4 5.7 7.5 0.5 8.8 5.7 0.4 0 0.4 0.4 49 5 58 305 23 0 23 0 -11.4 0 -11.1 -11.5 04/15/2005 08:00:00 7.8 0.5 8.8 6.5 7.8 0.5 8.8 6.5 0.4 0 0.4 0.4 46 3 44 305 22 0 22 0 -11.5 0 -11.3 -11.7 04/15/2005 08:10:00 7.7 0.5 9.1 6.1 7.6 0.6 9.5 5.7 0.4 0 0.4 0.4 45 5 45 305 22 0 22 0 -11.5 0 -11.3 -11.7 04/15/2005 08:20:00 7.7 0.5 8.8 6.1 7.6 0.6 8.8 5.3 0.4 0 0.4 0.4 47 4 48 305 22 0 22 0 -11.5 0 -11.3 -11.7 04/15/2005 08:30:00 7.9 0.5 9.5 6.5 7.8 0.6 9.1 5.7 0.4 0 0.4 0.4 43 4 42 305 22 0 22 0 -11.5 0 -11.3 -11.7 04/15/2005 08:40:00 8 0.6 9.1 6.5 7.9 0.7 9.1 5.7 0.4 0 0.4 0.4 41 4 39 305 22 0 22 0 -11.6 0 -11.3 -11.9 04/15/2005 08:50:00 7.8 0.5 9.1 6.5 7.7 0.6 8.8 6.1 0.4 0 0.4 0.4 41 4 37 305 22 0 22 0 -11.7 0 -11.5 -11.9 04/15/2005 09:00:00 7.6 0.5 8.8 6.1 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 41 4 42 305 22 0 22 0 -11.8 0 -11.5 -12.1 04/15/2005 09:10:00 7.7 0.5 9.1 6.5 7.6 0.6 9.1 6.1 0.4 0 0.4 0.4 41 4 46 305 23 0 22 0 -11.8 0 -11.7 -12.1 04/15/2005 09:20:00 7.8 0.6 8.8 6.1 7.7 0.6 8.8 6.1 0.4 0 0.4 0.4 37 4 45 305 23 0 23 0 -11.9 0 -11.7 -12.1 04/15/2005 09:30:00 7.5 0.7 8.8 5.7 7.4 0.6 8.8 5.3 0.4 0 0.4 0.4 35 4 35 305 24 0 24 0 -11.8 0 -11.7 -12.1 04/15/2005 09:40:00 7.5 0.5 8.8 6.1 7.4 0.5 8.4 6.1 0.4 0 0.4 0.4 35 4 36 305 24 0 24 0 -11.8 0 -11.7 -12.1 04/15/2005 09:50:00 7.1 0.6 8.8 5.7 6.9 0.7 8.4 5.3 0.4 0 0.4 0.4 34 4 38 305 25 0 25 0 -11.7 0 -11.5 -12.1 04/15/2005 10:00:00 7.3 0.5 8.4 5.7 7.2 0.5 8 5.7 0.4 0 0.4 0.4 31 4 33 305 27 0 26 0 -11.6 0 -11.3 -11.7 04/15/2005 10:10:00 7.3 0.5 8.8 6.1 7.3 0.5 8.4 6.1 0.4 0 0.4 0.4 37 6 30 305 28 0 28 0 -11.6 0 -11.3 -11.7 04/15/2005 10:20:00 7.2 0.4 8 5.7 7.1 0.5 8 5.7 0.4 0 0.4 0.4 40 4 41 305 28 0 28 0 -11.6 0 -11.3 -11.7 04/15/2005 10:30:00 7 0.6 8.4 4.9 7 0.7 8.4 4.9 0.4 0 0.4 0.4 40 6 44 305 28 0 28 0 -11.6 0 -11.5 -11.9 04/15/2005 10:40:00 7.3 0.5 8.4 5.7 7.3 0.6 8.4 5.3 0.4 0 0.4 0.4 42 4 45 305 29 0 28 0 -11.6 0 -11.3 -11.9 04/15/2005 10:50:00 7.2 0.5 8.4 5.7 7.3 0.5 8.8 5.7 0.4 0 0.4 0.4 43 5 42 305 30 0 30 0 -11.5 0 -11.3 -11.7 04/15/2005 11:00:00 7.2 0.5 8.8 6.1 7.2 0.5 9.1 6.1 0.4 0 0.4 0.4 37 4 40 305 31 0 31 0 -11.6 0 -11.3 -11.7 04/15/2005 11:10:00 7.1 0.4 8 5.7 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 43 5 40 305 31 0 31 0 -11.5 0 -11.3 -11.7 04/15/2005 11:20:00 7.1 0.6 8.4 5.3 7.1 0.6 8.8 5.7 0.4 0 0.4 0.4 41 5 39 305 32 0 32 0 -11.5 0 -11.3 -11.7 04/15/2005 11:30:00 7 0.4 8 6.1 7.1 0.4 8 5.7 0.4 0 0.4 0.4 41 5 43 305 32 0 32 0 -11.6 0 -11.3 -11.7 04/15/2005 11:40:00 6.5 0.7 8 4.6 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 35 7 30 305 32 0 32 0 -11.5 0 -11.1 -11.7 04/15/2005 11:50:00 6.6 0.6 8 5.3 6.6 0.6 8 4.9 0.4 0 0.4 0.4 29 5 33 305 33 0 33 0 -11.6 0 -11.3 -11.7 04/15/2005 12:00:00 6.9 0.4 8 5.7 7 0.5 8 5.3 0.4 0 0.4 0.4 37 4 34 305 33 0 33 0 -11.7 0 -11.3 -11.9 04/15/2005 12:10:00 6.8 0.4 8 5.7 6.9 0.5 8 5.3 0.4 0 0.4 0.4 37 6 40 305 34 0 33 0 -11.6 0 -11.3 -11.9 04/15/2005 12:20:00 6.3 0.6 7.6 4.9 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 32 6 25 305 36 1 36 0 -11.5 0 -11.1 -11.7 04/15/2005 12:30:00 6.8 0.4 8 5.3 6.8 0.5 8 4.9 0.4 0 0.4 0.4 35 5 34 305 39 0 39 0 -11.5 0 -11.1 -11.7 04/15/2005 12:40:00 6.7 0.4 7.6 5.7 6.8 0.5 8 5.7 0.4 0 0.4 0.4 38 5 40 305 41 1 40 0 -11.5 0 -11.3 -11.7 04/15/2005 12:50:00 6.8 0.5 8 5.3 6.8 0.5 7.6 5.3 0.4 0 0.4 0.4 39 6 36 305 42 0 42 0 -11.5 0 -11.1 -11.7 04/15/2005 13:00:00 6.9 0.5 8.4 5.7 7 0.6 8 5.3 0.4 0 0.4 0.4 41 7 48 305 41 0 42 0 -11.5 0 -11.3 -11.7 04/15/2005 13:10:00 7.1 0.5 8.4 5.3 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 37 5 41 305 41 0 41 0 -11.5 0 -10.9 -11.7 04/15/2005 13:20:00 7.1 0.4 8.4 5.7 7.2 0.4 8 5.7 0.4 0 0.4 0.4 41 5 42 305 40 0 40 0 -11.5 0 -11.3 -11.7 04/15/2005 13:30:00 7.2 0.4 8.4 6.1 7.3 0.4 8.4 6.1 0.4 0 0.4 0.4 41 4 41 305 40 0 40 0 -11.6 0 -11.5 -11.9 04/15/2005 13:40:00 6.9 0.5 8 5.3 6.9 0.6 8 5.3 0.4 0 0.4 0.4 41 6 37 305 39 0 39 0 -11.6 0 -11.5 -11.7 04/15/2005 13:50:00 6.9 0.5 8 5.3 6.9 0.5 8.4 5.3 0.4 0 0.4 0.4 38 5 42 305 40 0 40 0 -11.6 0 -11.5 -11.9 04/15/2005 14:00:00 6.9 0.5 8 5.7 7 0.5 8 5.7 0.4 0 0.4 0.4 46 6 42 305 39 0 40 0 -11.5 0 -11.5 -11.7 04/15/2005 14:10:00 6.7 0.5 8 4.9 6.8 0.6 8 5.3 0.4 0 0.4 0.4 43 6 36 305 40 0 39 0 -11.5 0 -11.3 -11.7 04/15/2005 14:20:00 6.8 0.6 8 4.9 6.9 0.6 8.4 4.9 0.4 0 0.4 0.4 49 5 56 305 40 0 40 0 -11.5 0 -11.5 -11.7 04/15/2005 14:30:00 6.5 0.5 7.6 5.3 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 40 6 39 305 40 0 41 0 -11.5 0 -11.3 -11.7 04/15/2005 14:40:00 6.5 0.5 7.6 4.9 6.5 0.6 7.6 4.6 0.4 0 0.4 0.4 38 5 36 305 42 1 42 0 -11.5 0 -11.3 -11.7 04/15/2005 14:50:00 6.7 0.4 7.6 5.7 6.7 0.4 8 5.7 0.4 0 0.4 0.4 39 4 41 305 43 0 43 0 -11.6 0 -11.5 -11.9 04/15/2005 15:00:00 6.4 0.5 7.2 4.2 6.4 0.6 7.6 4.2 0.4 0 0.4 0.4 46 5 46 305 44 0 45 0 -11.5 0 -11.3 -11.9 04/15/2005 15:10:00 6.5 0.5 7.6 4.9 6.6 0.5 7.6 4.9 0.4 0 0.4 0.4 38 4 29 305 44 0 44 0 -11.6 0 -11.5 -11.7 04/15/2005 15:20:00 6.5 0.4 7.2 5.3 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 44 3 45 305 45 0 45 0 -11.5 0 -11.3 -11.7 04/15/2005 15:30:00 6.2 0.6 8.4 4.6 6.2 0.6 8 4.6 0.4 0 0.4 0.4 40 7 46 305 45 0 45 0 -11.5 0 -11.3 -11.7 04/15/2005 15:40:00 6.4 0.4 7.6 5.3 6.5 0.5 8 4.9 0.4 0 0.4 0.4 42 5 40 305 45 0 46 0 -11.5 0 -11.1 -11.7 04/15/2005 15:50:00 6.5 0.5 7.6 4.9 6.5 0.5 7.6 4.6 0.4 0 0.4 0.4 46 6 50 305 45 0 45 0 -11.6 0 -11.3 -11.9 04/15/2005 16:00:00 6.8 0.5 8 5.7 6.8 0.5 8 5.3 0.4 0 0.4 0.4 49 6 48 305 45 0 45 0 -11.6 0 -11.3 -11.9 04/15/2005 16:10:00 6.8 0.6 8 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 45 4 43 305 44 0 44 0 -11.9 0.1 -11.5 -12.1 04/15/2005 16:20:00 6.9 0.4 8 5.3 6.8 0.5 7.6 5.3 0.4 0 0.4 0.4 46 4 46 305 44 0 44 0 -11.9 0.1 -11.5 -12.1 04/15/2005 16:30:00 6.6 0.5 8 5.3 6.7 0.5 8 4.9 0.4 0 0.4 0.4 43 6 50 305 44 0 44 0 -11.9 0.1 -11.5 -12.1 04/15/2005 16:40:00 6.3 0.4 7.6 4.9 6.4 0.5 7.6 4.9 0.4 0 0.4 0.4 41 6 43 305 44 0 44 0 -11.8 0 -11.5 -12.1 04/15/2005 16:50:00 6.2 0.5 7.2 4.9 6.2 0.5 7.2 4.9 0.4 0 0.4 0.4 44 7 35 305 44 0 44 0 -11.9 0 -11.5 -12.1 04/15/2005 17:00:00 6.6 0.4 7.6 5.7 6.7 0.4 7.6 5.3 0.4 0 0.4 0.4 44 5 46 305 44 0 44 0 -12 0 -11.7 -12.3 04/15/2005 17:10:00 6.2 0.5 7.6 4.9 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 47 6 46 305 44 0 44 0 -11.9 0.1 -11.5 -12.1 04/15/2005 17:20:00 6.2 0.5 7.2 4.9 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 45 5 44 305 44 0 44 0 -12.1 0.2 -11.5 -12.5 04/15/2005 17:30:00 6.2 0.5 7.6 4.6 6.2 0.6 8 4.6 0.4 0 0.4 0.4 47 4 48 305 42 0 41 0 -12.3 0.1 -12.1 -12.5 04/15/2005 17:40:00 6.5 0.4 7.6 5.3 6.5 0.4 7.6 5.7 0.4 0 0.4 0.4 46 5 39 305 41 0 40 0 -12.3 0 -12.1 -12.5 04/15/2005 17:50:00 6.9 0.5 8 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 50 4 55 305 40 0 40 0 -12.2 0 -11.9 -12.5 04/15/2005 18:00:00 7.1 0.4 8 6.1 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 52 4 55 305 40 0 39 0 -12.4 0.1 -12.1 -12.5 04/15/2005 18:10:00 6.9 0.5 8 5.7 6.9 0.5 8 5.7 0.4 0 0.4 0.4 50 6 46 305 38 0 38 0 -12.6 0 -12.5 -12.7 04/15/2005 18:20:00 6.8 0.5 8.4 5.3 6.7 0.6 8 4.9 0.4 0 0.4 0.4 50 6 46 305 36 0 36 0 -12.6 0 -12.5 -12.9 04/15/2005 18:30:00 6.6 0.4 8 5.7 6.5 0.5 7.6 4.9 0.4 0 0.4 0.4 49 6 54 305 35 0 35 0 -12.6 0 -12.5 -12.9 04/15/2005 18:40:00 6.4 0.6 8 4.6 6.3 0.6 8 4.6 0.4 0 0.4 0.4 50 7 50 305 33 1 33 0 -12.6 0 -12.5 -12.9 04/15/2005 18:50:00 6.3 0.5 7.2 4.9 6.3 0.6 7.2 4.2 0.4 0 0.4 0.4 50 5 53 305 29 1 31 0 -12.6 0 -12.5 -12.9 04/15/2005 19:00:00 6.2 0.5 7.6 4.9 6.2 0.6 7.6 4.2 0.4 0 0.4 0.4 50 5 45 305 28 0 28 0 -12.6 0 -12.5 -12.9 04/15/2005 19:10:00 6.2 0.4 7.2 4.6 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 49 6 50 305 27 0 27 0 -12.7 0 -12.5 -12.9 04/15/2005 19:20:00 6.1 0.5 8 4.6 6.1 0.6 8.4 4.6 0.4 0 0.4 0.4 52 6 51 305 26 0 26 0 -12.8 0 -12.5 -12.9 04/15/2005 19:30:00 5.7 0.6 7.2 4.2 5.7 0.7 7.6 3.8 0.4 0 0.4 0.4 50 8 47 305 25 0 25 0 -12.8 0 -12.5 -12.9 04/15/2005 19:40:00 6 0.5 6.8 4.9 5.9 0.6 6.8 4.2 0.4 0 0.4 0.4 51 7 64 305 24 0 24 0 -12.9 0.1 -12.7 -13.1 04/15/2005 19:50:00 5.9 0.4 6.8 4.6 5.9 0.5 7.2 4.2 0.4 0 0.4 0.4 54 5 60 305 23 0 23 0 -12.9 0 -12.7 -13.1 04/15/2005 20:00:00 5.9 0.6 7.2 4.2 5.8 0.7 7.6 4.2 0.4 0 0.4 0.4 48 6 54 305 22 0 22 0 -13 0 -12.7 -13.1 04/15/2005 20:10:00 6.3 0.4 7.6 5.3 6.2 0.4 7.6 5.3 0.4 0 0.4 0.4 52 5 56 305 22 0 22 0 -13.1 0 -12.9 -13.3 04/15/2005 20:20:00 6 0.4 7.2 4.9 6 0.4 7.2 4.9 0.4 0 0.4 0.4 50 5 54 305 21 0 21 0 -13.2 0 -12.9 -13.3 04/15/2005 20:30:00 5.8 0.4 6.8 4.9 5.8 0.4 6.8 4.9 0.4 0 0.4 0.4 48 5 49 305 20 0 20 0 -13.2 0 -12.9 -13.3 04/15/2005 20:40:00 5.8 0.5 7.2 4.9 5.8 0.5 7.2 4.6 0.4 0 0.4 0.4 52 7 53 305 20 0 20 0 -13.2 0 -12.9 -13.3 04/15/2005 20:50:00 6 0.5 7.2 4.9 5.9 0.6 6.8 4.6 0.4 0 0.4 0.4 56 6 62 305 19 0 19 0 -13.3 0 -13.1 -13.5 04/15/2005 21:00:00 6 0.5 7.6 4.6 6 0.5 7.2 4.6 0.4 0 0.4 0.4 54 8 48 305 19 0 19 0 -13.4 0 -13.1 -13.5 04/15/2005 21:10:00 5.7 0.4 6.5 4.6 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 53 5 44 305 18 0 18 0 -13.4 0 -13.1 -13.5 04/15/2005 21:20:00 5.4 0.5 6.8 4.2 5.3 0.6 6.8 4.2 0.4 0 0.4 0.4 53 5 52 305 18 0 18 0 -13.5 0 -13.3 -13.7 04/15/2005 21:30:00 5.4 0.5 6.8 4.6 5.4 0.5 7.2 4.2 0.4 0 0.4 0.4 52 5 60 305 18 0 18 0 -13.5 0 -13.3 -13.7 04/15/2005 21:40:00 4.8 0.6 6.5 3.8 4.6 0.6 6.1 3.4 0.4 0 0.4 0.4 56 7 59 305 17 0 17 0 -13.5 0 -13.3 -13.7 04/15/2005 21:50:00 4.9 0.5 6.1 3.8 4.8 0.5 6.1 3.8 0.4 0 0.4 0.4 58 8 51 305 17 0 17 0 -13.6 0 -13.3 -13.7 04/15/2005 22:00:00 5.6 0.5 7.2 3.8 5.3 0.5 6.8 3.8 0.4 0 0.4 0.4 68 7 68 305 17 0 17 0 -13.6 0 -13.3 -13.7 04/15/2005 22:10:00 5.3 0.5 6.5 3.8 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 66 8 70 305 16 0 16 0 -13.7 0 -13.5 -13.9 04/15/2005 22:20:00 5.9 0.5 7.2 4.6 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 74 7 69 305 16 0 16 0 -13.7 0 -13.5 -14.1 04/15/2005 22:30:00 5.7 0.5 6.8 4.6 5.3 0.5 6.5 3.8 0.4 0 0.4 0.4 75 6 72 305 16 0 16 0 -14 0 -13.7 -14.1 04/15/2005 22:40:00 5.6 0.5 6.8 4.2 5.2 0.5 6.5 3.8 0.4 0 0.4 0.4 83 7 82 305 15 0 15 0 -14.1 0 -13.9 -14.3 04/15/2005 22:50:00 6.1 0.4 7.2 4.9 5.5 0.4 6.8 4.6 0.4 0 0.4 0.4 92 4 87 305 15 0 15 0 -14.3 0 -14.3 -14.4 04/15/2005 23:00:00 6.1 0.5 7.2 4.9 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 88 7 92 305 15 0 15 0 -14.4 0 -14.3 -14.6 04/15/2005 23:10:00 6.3 0.5 7.6 4.9 5.9 0.5 7.6 4.6 0.4 0 0.4 0.4 81 6 87 305 14 0 14 0 -14.6 0.1 -14.3 -14.6 04/15/2005 23:20:00 6.2 0.5 7.6 4.6 5.8 0.5 7.2 4.6 0.4 0 0.4 0.4 81 6 84 305 14 0 14 0 -14.7 0 -14.6 -14.8 04/15/2005 23:30:00 6.5 0.5 8 5.3 6 0.5 7.6 4.9 0.4 0 0.4 0.4 82 4 77 305 14 0 14 0 -14.9 0.1 -14.3 -15 04/15/2005 23:40:00 6.4 0.5 7.6 5.3 6 0.5 7.2 4.9 0.4 0 0.4 0.4 82 4 82 305 13 0 13 0 -15.1 0 -15 -15.2 04/15/2005 23:50:00 6.1 0.6 7.6 4.9 5.6 0.7 7.2 4.2 0.4 0 0.4 0.4 76 5 71 305 13 0 13 0 -15.2 0 -15 -15.2 04/16/2005 00:00:00 6.3 0.5 7.6 4.6 5.9 0.5 7.2 4.2 0.4 0 0.4 0.4 78 7 73 305 13 0 13 0 -15.1 0 -14.8 -15.4 04/16/2005 00:10:00 6.5 0.5 7.6 5.3 6 0.5 7.2 4.9 0.4 0 0.4 0.4 78 5 73 305 13 0 13 0 -15.4 0 -15.2 -15.6 04/16/2005 00:20:00 6.7 0.5 8 5.3 6.4 0.6 8 4.9 0.4 0 0.4 0.4 74 4 70 305 12 0 12 0 -15.6 0 -15.4 -15.8 04/16/2005 00:30:00 7 0.5 8 5.7 6.7 0.5 8 5.3 0.4 0 0.4 0.4 72 4 73 305 12 0 12 0 -15.7 0 -15.6 -15.8 04/16/2005 00:40:00 6.6 0.5 7.6 4.9 6.2 0.5 7.6 4.6 0.4 0 0.4 0.4 72 4 72 305 12 0 12 0 -15.8 0 -15.6 -16 04/16/2005 00:50:00 6.1 0.5 7.2 4.9 5.8 0.5 7.2 4.6 0.4 0 0.4 0.4 73 4 72 305 11 0 12 0 -15.9 0 -15.8 -16 04/16/2005 01:00:00 6.1 0.5 7.2 4.9 5.7 0.5 7.2 4.6 0.4 0 0.4 0.4 75 5 72 305 11 0 11 0 -16.2 0.1 -16 -16.4 04/16/2005 01:10:00 6.2 0.4 7.2 4.9 5.7 0.4 6.8 4.6 0.4 0 0.4 0.4 76 4 78 305 11 0 11 0 -16.4 0 -16.2 -16.6 04/16/2005 01:20:00 5.9 0.5 7.2 4.6 5.5 0.5 6.8 4.2 0.4 0 0.4 0.4 74 6 80 305 11 0 11 0 -16.5 0 -16.4 -16.6 04/16/2005 01:30:00 5.5 0.4 6.8 4.6 5.1 0.4 6.5 4.2 0.4 0 0.4 0.4 77 6 74 305 11 0 11 0 -16.5 0 -16.2 -16.6 04/16/2005 01:40:00 5.6 0.4 6.5 4.6 5.1 0.4 6.1 3.8 0.4 0 0.4 0.4 81 5 78 305 10 0 10 0 -16.8 0 -16.6 -16.9 04/16/2005 01:50:00 5.7 0.4 6.8 4.6 5.1 0.4 6.1 4.2 0.4 0 0.4 0.4 82 4 78 305 10 0 10 0 -16.9 0 -16.9 -17.1 04/16/2005 02:00:00 5.4 0.4 6.1 4.2 4.9 0.4 5.7 3.8 0.4 0 0.4 0.4 78 5 80 305 10 0 10 0 -16.9 0 -16.9 -16.9 04/16/2005 02:10:00 5.2 0.4 6.1 4.2 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 78 5 75 305 10 0 10 0 -17.1 0 -16.9 -17.3 04/16/2005 02:20:00 5.1 0.4 6.1 4.2 4.7 0.5 5.7 3.8 0.4 0 0.4 0.4 75 5 82 305 9 0 9 0 -17 0 -16.9 -17.3 04/16/2005 02:30:00 5.2 0.4 6.5 4.2 4.8 0.4 5.7 3.8 0.4 0 0.4 0.4 75 5 74 305 9 0 9 0 -17.1 0 -16.9 -17.3 04/16/2005 02:40:00 4.8 0.4 6.1 3.8 4.5 0.4 5.7 3.8 0.4 0 0.4 0.4 76 5 74 305 9 0 9 0 -17.2 0 -16.9 -17.3 04/16/2005 02:50:00 5.1 0.4 6.1 4.2 4.7 0.4 5.7 3.8 0.4 0 0.4 0.4 79 5 86 305 9 0 9 0 -17.2 0 -16.9 -17.3 04/16/2005 03:00:00 5.6 0.4 6.5 4.6 5.2 0.3 6.1 4.6 0.4 0 0.4 0.4 81 4 90 305 9 0 9 0 -17.1 0 -16.9 -17.3 04/16/2005 03:10:00 5.5 0.4 6.5 4.6 5 0.4 6.1 4.2 0.4 0 0.4 0.4 84 4 86 305 9 0 9 0 -17.3 0.1 -16.9 -17.5 04/16/2005 03:20:00 5.3 0.3 6.1 4.6 4.8 0.3 5.7 4.2 0.4 0 0.4 0.4 87 5 84 305 9 0 9 0 -17.5 0 -17.3 -17.7 04/16/2005 03:30:00 5.5 0.4 6.5 4.6 4.9 0.3 5.7 4.2 0.4 0 0.4 0.4 92 3 93 305 9 0 9 0 -17.7 0 -17.5 -17.9 04/16/2005 03:40:00 5.4 0.4 6.5 4.6 4.9 0.4 5.7 3.8 0.4 0 0.4 0.4 95 5 95 305 9 0 9 0 -17.8 0 -17.5 -17.9 04/16/2005 03:50:00 5.5 0.3 6.5 4.6 5 0.3 5.7 3.8 0.4 0 0.4 0.4 98 4 96 305 8 0 8 0 -17.8 0 -17.7 -18.1 04/16/2005 04:00:00 5.8 0.4 6.5 4.9 5.3 0.4 6.1 4.2 0.4 0 0.4 0.4 100 3 102 305 8 0 8 0 -17.7 0 -17.5 -17.9 04/16/2005 04:10:00 5.7 0.4 6.5 4.2 5.2 0.3 6.1 4.2 0.4 0 0.4 0.4 97 5 99 305 8 0 8 0 -17.8 0 -17.5 -18.1 04/16/2005 04:20:00 5.1 0.5 6.5 3.8 4.6 0.4 5.7 3.4 0.4 0 0.4 0.4 88 6 82 305 8 0 8 0 -17.9 0 -17.7 -18.1 04/16/2005 04:30:00 4.7 0.4 5.7 3.8 4.3 0.4 5.3 3 0.4 0 0.4 0.4 79 7 78 305 8 0 8 0 -18 0 -17.9 -18.1 04/16/2005 04:40:00 4.9 0.5 6.1 3.8 4.5 0.4 5.7 3.4 0.4 0 0.4 0.4 83 7 75 305 8 0 8 0 -18.1 0 -17.9 -18.4 04/16/2005 04:50:00 4.6 0.3 5.7 3.8 4.3 0.3 5.7 3.4 0.4 0 0.4 0.4 71 8 63 305 8 0 8 0 -18.2 0 -18.1 -18.4 04/16/2005 05:00:00 4.5 0.4 5.3 3.4 4.4 0.4 5.3 3.4 0.4 0 0.4 0.4 59 7 64 305 8 0 8 0 -17.8 0.3 -17.3 -18.2 04/16/2005 05:10:00 4.9 0.3 6.1 4.2 4.9 0.4 6.1 3.8 0.4 0 0.4 0.4 55 4 60 305 8 0 8 0 -17.3 0.1 -17.1 -17.5 04/16/2005 05:20:00 3.9 0.4 4.6 3 4 0.4 4.9 3 0.4 0 0.4 0.4 55 6 58 305 8 0 8 0 -17.2 0 -16.9 -17.3 04/16/2005 05:30:00 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 0.4 0 0.4 0.4 53 6 61 305 8 0 8 0 -17.2 0 -16.9 -17.3 04/16/2005 05:40:00 2.8 0.5 3.8 1.9 2.8 0.5 4.2 1.9 0.4 0 0.4 0.4 54 7 50 305 8 0 8 0 -17.1 0 -16.9 -17.1 04/16/2005 05:50:00 2.4 0.4 3.4 1.1 2.4 0.4 3 1.5 0.4 0 0.4 0.4 52 5 59 305 8 0 8 0 -17 0 -16.9 -17.1 04/16/2005 06:00:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 0.4 0 0.4 0.4 56 8 58 305 8 0 8 0 -16.9 0 -16.6 -17.1 04/16/2005 06:10:00 2.8 0.3 3.4 1.9 2.8 0.4 3.8 1.9 0.4 0 0.4 0.4 59 9 60 305 8 0 8 0 -16.9 0 -16.9 -17.1 04/16/2005 06:20:00 2.6 0.4 3.8 1.5 2.6 0.3 3.4 1.9 0.4 0 0.4 0.4 52 7 40 305 8 0 8 0 -16.9 0 -16.6 -16.9 04/16/2005 06:30:00 3 0.4 4.2 1.9 3 0.5 4.2 1.5 0.4 0 0.4 0.4 53 11 25 305 8 0 8 0 -16.7 0.1 -16.6 -16.9 04/16/2005 06:40:00 3 0.4 3.8 1.9 2.9 0.3 3.8 1.9 0.4 0 0.4 0.4 48 7 40 305 8 0 8 0 -16.9 0 -16.6 -16.9 04/16/2005 06:50:00 3.2 0.5 4.6 1.9 3.1 0.5 4.6 1.9 0.4 0 0.4 0.4 47 8 43 305 8 0 8 0 -16.8 0 -16.6 -16.9 04/16/2005 07:00:00 3.8 0.5 4.9 2.6 3.7 0.5 4.9 2.6 0.4 0 0.4 0.4 45 9 60 305 8 0 8 0 -16.9 0 -16.6 -16.9 04/16/2005 07:10:00 4.4 0.9 8.4 2.6 4.3 0.9 7.6 2.6 0.4 0 0.4 0.4 39 10 22 305 8 0 8 0 -16.7 0.2 -16.4 -16.9 04/16/2005 07:20:00 7.6 0.9 9.5 4.9 7.6 1 9.1 4.9 0.4 0 0.4 0.4 33 9 35 305 8 0 8 0 -16.1 0.2 -15.8 -16.6 04/16/2005 07:30:00 6.9 0.6 8 5.3 6.8 0.7 8.4 5.3 0.4 0 0.4 0.4 32 6 31 305 9 0 8 0 -15.9 0 -15.8 -16.2 04/16/2005 07:40:00 7.1 0.6 8.8 5.3 7.1 0.6 9.1 5.3 0.4 0 0.4 0.4 37 6 42 305 9 0 9 0 -15.9 0 -15.8 -16 04/16/2005 07:50:00 7.3 0.7 9.1 5.3 7.5 0.7 9.1 5.3 0.4 0 0.4 0.4 28 6 26 305 9 0 9 0 -15.8 0 -15.6 -16 04/16/2005 08:00:00 8.1 0.6 9.5 6.1 8.4 0.7 9.9 6.1 0.4 0 0.4 0.4 19 6 17 305 9 0 9 0 -15.7 0 -15.4 -15.8 04/16/2005 08:10:00 7.9 0.6 9.1 6.1 8.2 0.7 9.5 6.1 0.4 0 0.4 0.4 24 5 26 305 10 0 10 0 -15.7 0 -15.4 -15.8 04/16/2005 08:20:00 7.4 0.7 9.1 5.3 7.7 0.9 9.5 5.3 0.4 0 0.4 0.4 17 7 20 305 10 0 10 0 -15.6 0 -15.2 -15.6 04/16/2005 08:30:00 9 0.7 10.3 6.8 9 0.7 10.7 6.8 0.4 0 0.4 0.4 22 4 23 305 11 0 11 0 -15.6 0 -15.4 -15.8 04/16/2005 08:40:00 8.4 0.6 10.3 6.5 8.5 0.6 10.7 6.8 0.4 0 0.4 0.4 15 5 20 305 11 0 11 0 -15.6 0 -15.2 -15.8 04/16/2005 08:50:00 8.3 0.8 10.3 6.1 8.3 0.9 10.3 6.1 0.4 0 0.4 0.4 11 5 12 305 11 0 11 0 -15.4 0.1 -15 -15.6 04/16/2005 09:00:00 9.6 0.7 11.8 7.6 9.7 0.8 12.2 7.6 0.4 0 0.4 0.4 1 5 13 305 11 0 11 0 -15.2 0 -15 -15.2 04/16/2005 09:10:00 10.2 1.1 12.6 7.6 10.4 1.2 12.6 7.6 0.4 0 0.4 0.4 4 5 7 305 12 0 12 0 -15 0 -14.6 -15 04/16/2005 09:20:00 10.9 0.9 13 8.8 11 1 13.3 8.4 0.4 0 0.4 0.4 4 6 3 305 12 0 12 0 -14.9 0 -14.6 -15 04/16/2005 09:30:00 10.7 0.9 12.6 7.6 10.7 0.9 13 8 0.4 0 0.4 0.4 8 5 12 305 12 0 12 0 -15 0 -14.6 -15 04/16/2005 09:40:00 11 0.8 13 7.6 11.1 0.9 13.7 8.8 0.4 0 0.4 0.4 358 4 9 305 12 0 12 0 -15.1 0.1 -14.8 -15.2 04/16/2005 09:50:00 11 1 13.3 8 11.1 1 13.3 8.4 0.4 0 0.4 0.4 5 6 8 305 12 0 12 0 -15.2 0 -14.8 -15.2 04/16/2005 10:00:00 11.6 1 13.3 8.8 11.5 1.1 13.7 8.8 0.4 0 0.4 0.4 6 5 8 305 13 0 13 0 -15.2 0 -14.8 -15.4 04/16/2005 10:10:00 11.1 1.1 13 8.4 11.2 1.1 13.7 8.8 0.4 0 0.4 0.4 8 5 12 305 13 0 13 0 -15.3 0 -15 -15.6 04/16/2005 10:20:00 11 1.1 13 8 11 1.1 13.7 8.8 0.4 0 0.4 0.4 7 5 15 305 13 0 13 0 -15.2 0 -14.8 -15.4 04/16/2005 10:30:00 11.2 1 13 8.4 11.3 1.1 13.3 8 0.4 0 0.4 0.4 4 5 1 305 13 0 13 0 -15.1 0.1 -14.6 -15.2 04/16/2005 10:40:00 10.8 1 13 8.4 10.8 1 13.3 7.6 0.4 0 0.4 0.4 9 5 9 305 13 0 13 0 -15 0 -14.6 -15.2 04/16/2005 10:50:00 11.2 0.9 13.3 8.8 11.3 1 13 8.4 0.4 0 0.4 0.4 8 5 11 305 14 0 14 0 -15 0 -14.6 -15 04/16/2005 11:00:00 11.2 0.9 13 8.8 11.3 0.9 13.7 8.8 0.4 0 0.4 0.4 8 6 12 305 14 0 14 0 -14.9 0 -14.4 -15 04/16/2005 11:10:00 11.1 1.1 13.3 8.8 11.3 1.2 14.1 8.4 0.4 0 0.4 0.4 3 7 16 305 14 0 14 0 -14.8 0 -14.4 -15 04/16/2005 11:20:00 11.4 1 14.1 8.4 11.5 1 14.1 8.8 0.4 0 0.4 0.4 1 4 359 305 14 0 14 0 -14.8 0 -14.4 -15 04/16/2005 11:30:00 11.6 1.1 14.1 8.8 11.7 1.2 14.1 8 0.4 0 0.4 0.4 6 4 4 305 14 0 14 0 -14.8 0 -14.4 -15 04/16/2005 11:40:00 11.1 0.9 13.3 9.1 11.1 1 13.7 8.4 0.4 0 0.4 0.4 8 4 12 305 15 0 15 0 -14.7 0 -14.3 -15 04/16/2005 11:50:00 10.9 1.1 13.7 8 10.9 1.2 13.7 7.6 0.4 0 0.4 0.4 9 5 11 305 15 0 15 0 -14.7 0 -14.3 -14.8 04/16/2005 12:00:00 10.8 0.9 13.3 8 10.9 1 13 8.4 0.4 0 0.4 0.4 10 4 7 305 15 0 15 0 -14.6 0.1 -14.3 -14.6 04/16/2005 12:10:00 10.2 1.2 13.3 7.2 10.2 1.3 13.3 7.6 0.4 0 0.4 0.4 6 5 4 305 16 0 15 0 -14.5 0 -14.3 -14.6 04/16/2005 12:20:00 10 0.9 11.8 7.6 10.1 1 12.2 7.6 0.4 0 0.4 0.4 6 5 11 305 16 0 16 0 -14.3 0 -14.3 -14.6 04/16/2005 12:30:00 9.6 0.9 11.8 7.6 9.7 1 11.8 6.8 0.4 0 0.4 0.4 1 7 2 305 17 0 16 0 -14.2 0 -13.9 -14.4 04/16/2005 12:40:00 10.1 1 12.2 7.2 10.2 1 12.6 8 0.4 0 0.4 0.4 358 4 358 305 17 0 17 0 -14.2 0 -13.9 -14.3 04/16/2005 12:50:00 9.2 0.9 11.5 6.8 9.3 0.9 11.5 7.2 0.4 0 0.4 0.4 357 5 357 305 17 0 18 0 -14 0 -13.7 -14.3 04/16/2005 13:00:00 8.9 1 11.1 6.1 9.1 1 11.5 6.1 0.4 0 0.4 0.4 354 5 354 305 18 0 18 0 -13.9 0 -13.3 -14.1 04/16/2005 13:10:00 8.9 0.7 10.3 6.8 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 357 6 0 305 18 0 18 0 -13.8 0 -13.3 -14.1 04/16/2005 13:20:00 9.2 0.9 11.5 6.8 9.4 0.8 11.5 7.2 0.4 0 0.4 0.4 357 5 359 305 18 0 18 0 -13.8 0 -13.7 -14.1 04/16/2005 13:30:00 9 0.7 11.5 7.2 9.1 0.7 11.8 6.8 0.4 0 0.4 0.4 355 5 356 305 18 0 18 0 -13.8 0 -13.7 -13.9 04/16/2005 13:40:00 9.5 0.9 11.5 6.8 9.7 1 11.5 7.2 0.4 0 0.4 0.4 358 4 3 305 18 0 18 0 -13.9 0 -13.7 -14.3 04/16/2005 13:50:00 9.5 0.9 11.8 7.2 9.6 0.9 11.8 7.6 0.4 0 0.4 0.4 358 5 0 305 18 0 18 0 -13.9 0.1 -13.7 -14.1 04/16/2005 14:00:00 8.7 1.1 11.1 5.7 8.8 1.1 11.5 5.7 0.4 0 0.4 0.4 6 6 13 305 18 0 18 0 -13.9 0 -13.7 -14.1 04/16/2005 14:10:00 9.2 0.9 11.5 6.8 9.4 1 11.8 6.8 0.4 0 0.4 0.4 9 5 11 305 19 0 19 0 -14 0 -13.7 -14.3 04/16/2005 14:20:00 8.5 0.8 10.3 6.5 8.6 0.8 10.7 6.8 0.4 0 0.4 0.4 9 5 9 305 19 0 19 0 -13.9 0 -13.5 -14.1 04/16/2005 14:30:00 8.9 1 11.1 6.1 9 1 11.1 6.5 0.4 0 0.4 0.4 5 5 8 305 19 0 20 0 -13.8 0.1 -13.3 -14.1 04/16/2005 14:40:00 7.9 0.9 10.3 5.7 8 0.9 10.7 5.7 0.4 0 0.4 0.4 2 6 3 305 20 0 19 0 -13.6 0 -13.3 -13.7 04/16/2005 14:50:00 8.8 0.8 11.1 6.5 8.9 0.8 10.7 6.5 0.4 0 0.4 0.4 6 5 9 305 20 0 20 0 -13.7 0.1 -13.3 -13.9 04/16/2005 15:00:00 8.4 0.9 10.3 6.1 8.5 0.9 10.7 6.1 0.4 0 0.4 0.4 5 7 356 305 20 0 21 0 -13.6 0.1 -13.1 -13.9 04/16/2005 15:10:00 7.7 1 10.3 5.3 7.9 1 10.3 5.7 0.4 0 0.4 0.4 359 4 358 305 21 0 21 0 -13.5 0.1 -13.1 -13.7 04/16/2005 15:20:00 7.4 0.7 9.1 5.7 7.5 0.7 9.9 5.3 0.4 0 0.4 0.4 353 9 345 305 22 0 22 0 -13.4 0.1 -12.9 -13.7 04/16/2005 15:30:00 8.2 1.1 10.7 5.7 8.4 1 11.1 5.7 0.4 0 0.4 0.4 353 7 350 305 22 0 22 0 -13.3 0 -12.9 -13.5 04/16/2005 15:40:00 9.4 1 11.5 6.8 9.5 1 12.2 6.5 0.4 0 0.4 0.4 349 4 349 305 21 0 21 0 -13.5 0.1 -13.1 -13.7 04/16/2005 15:50:00 8.4 1 10.7 6.1 8.6 1.1 11.1 5.3 0.4 0 0.4 0.4 354 5 357 305 21 0 21 0 -13.4 0.1 -13.1 -13.7 04/16/2005 16:00:00 8.6 0.9 10.7 6.1 8.8 0.9 11.1 6.8 0.4 0 0.4 0.4 352 6 358 305 21 0 22 0 -13.5 0.1 -12.9 -13.7 04/16/2005 16:10:00 8 1.1 11.1 5.3 8.1 1.1 11.1 5.3 0.4 0 0.4 0.4 354 6 349 305 21 0 21 0 -13.5 0.1 -13.1 -13.9 04/16/2005 16:20:00 7 0.7 8.8 4.9 7.2 0.8 9.1 5.3 0.4 0 0.4 0.4 354 7 14 305 21 0 21 0 -13.4 0.2 -12.9 -13.7 04/16/2005 16:30:00 7.4 1 9.9 4.9 7.5 1.1 10.3 4.9 0.4 0 0.4 0.4 357 9 355 305 24 1 24 0 -13.2 0.1 -12.7 -13.5 04/16/2005 16:40:00 8.7 0.8 10.3 6.5 8.9 0.8 11.1 6.5 0.4 0 0.4 0.4 347 5 341 305 23 1 23 0 -13.5 0.1 -12.9 -13.7 04/16/2005 16:50:00 8.5 1 11.5 5.7 8.6 1 10.7 6.1 0.4 0 0.4 0.4 349 7 334 305 22 0 22 0 -13.6 0.1 -13.3 -14.1 04/16/2005 17:00:00 7.1 1.1 9.5 4.6 7.3 1.1 10.3 4.6 0.4 0 0.4 0.4 353 7 350 305 21 0 21 0 -13.6 0.2 -13.1 -13.9 04/16/2005 17:10:00 8.6 0.8 10.3 6.5 8.9 0.8 10.7 6.5 0.4 0 0.4 0.4 352 4 350 305 20 1 21 0 -13.8 0.1 -13.3 -14.3 04/16/2005 17:20:00 7.5 1 9.5 4.6 7.6 1 9.9 4.6 0.4 0 0.4 0.4 357 6 4 305 20 1 20 0 -13.4 0.2 -12.9 -13.7 04/16/2005 17:30:00 6.6 0.8 8.4 4.2 6.7 0.8 8.8 4.6 0.4 0 0.4 0.4 356 8 354 305 22 0 22 0 -13.3 0.2 -12.9 -13.7 04/16/2005 17:40:00 7.7 0.9 9.9 5.3 7.8 0.9 9.5 5.3 0.4 0 0.4 0.4 355 6 3 305 22 0 22 0 -13.2 0.1 -12.9 -13.5 04/16/2005 17:50:00 8.5 0.9 11.1 5.7 8.7 1 11.5 6.5 0.4 0 0.4 0.4 357 6 352 305 22 0 22 0 -13.3 0.1 -12.9 -13.5 04/16/2005 18:00:00 8.4 0.9 10.3 6.5 8.5 0.9 10.7 6.5 0.4 0 0.4 0.4 355 6 355 305 22 0 22 0 -13.3 0 -12.9 -13.5 04/16/2005 18:10:00 9.6 1.1 11.8 6.5 9.6 1.2 12.2 6.5 0.4 0 0.4 0.4 0 5 5 305 22 0 22 0 -13.3 0.2 -12.9 -13.9 04/16/2005 18:20:00 9.4 1.2 11.8 6.1 9.5 1.2 12.2 6.1 0.4 0 0.4 0.4 355 7 350 305 20 0 20 0 -13.6 0.1 -13.3 -14.1 04/16/2005 18:30:00 8.6 0.8 10.3 5.7 8.7 0.9 10.7 6.1 0.4 0 0.4 0.4 356 6 0 305 19 0 19 0 -13.5 0.2 -13.1 -13.7 04/16/2005 18:40:00 8.8 1 11.5 6.5 9.1 1 11.8 6.8 0.4 0 0.4 0.4 353 6 351 305 19 0 19 0 -13.5 0 -13.3 -13.7 04/16/2005 18:50:00 9.1 1.1 12.2 6.5 9.2 1.1 12.2 6.8 0.4 0 0.4 0.4 353 6 357 305 19 0 18 0 -13.6 0.1 -13.3 -13.7 04/16/2005 19:00:00 9.9 0.9 12.2 7.6 10 0.9 12.2 7.6 0.4 0 0.4 0.4 353 6 357 305 18 1 18 0 -13.8 0.2 -13.3 -14.3 04/16/2005 19:10:00 10.4 1 12.6 7.6 10.5 1.1 13 7.6 0.4 0 0.4 0.4 353 5 357 305 16 0 16 0 -13.8 0.1 -13.5 -14.3 04/16/2005 19:20:00 10.3 0.9 12.6 7.6 10.3 0.9 12.6 7.6 0.4 0 0.4 0.4 355 7 358 305 17 0 17 0 -13.6 0.1 -13.3 -13.9 04/16/2005 19:30:00 11 1.1 13.3 8.4 11.2 1.1 13.7 8.4 0.4 0 0.4 0.4 353 5 358 305 17 0 17 0 -13.9 0.2 -13.3 -14.3 04/16/2005 19:40:00 10.6 1 13 7.2 10.8 1.1 13.7 8 0.4 0 0.4 0.4 353 5 3 305 15 0 15 0 -14.2 0 -13.7 -14.3 04/16/2005 19:50:00 10.7 0.9 12.6 8 10.7 1 13 8 0.4 0 0.4 0.4 352 6 345 305 15 0 15 0 -14.2 0 -13.7 -14.3 04/16/2005 20:00:00 9.3 1.1 13 6.5 9.5 1.1 11.8 6.8 0.4 0 0.4 0.4 354 6 353 305 14 0 14 0 -14.1 0.1 -13.7 -14.4 04/16/2005 20:10:00 11.2 1.1 13.7 8.4 11.4 1.1 14.1 8.8 0.4 0 0.4 0.4 357 7 353 305 14 0 14 0 -14 0.1 -13.7 -14.3 04/16/2005 20:20:00 12.4 0.9 14.9 9.9 12.5 0.9 14.9 9.5 0.4 0 0.4 0.4 357 5 350 305 14 0 13 0 -14.2 0 -13.9 -14.4 04/16/2005 20:30:00 13.2 1.1 15.6 9.5 13.2 1.2 15.6 9.9 0.4 0 0.4 0.4 358 6 5 305 13 0 13 0 -14.3 0 -14.3 -14.4 04/16/2005 20:40:00 12 1.3 15.3 8 12 1.2 14.9 8.4 0.4 0 0.4 0.4 359 6 2 305 13 0 13 0 -14.3 0 -13.9 -14.6 04/16/2005 20:50:00 13 1.5 16.1 9.1 13.1 1.5 16.8 9.1 0.4 0 0.4 0.4 354 5 353 305 13 0 13 0 -14.4 0.1 -14.3 -14.6 04/16/2005 21:00:00 14.1 1.4 17.2 9.9 14 1.5 17.2 10.7 0.4 0 0.4 0.4 356 5 0 305 13 0 13 0 -14.5 0.1 -14.3 -14.6 04/16/2005 21:10:00 12.6 1.3 15.3 8.4 12.7 1.3 15.3 8.8 0.4 0 0.4 0.4 352 5 346 305 12 0 12 0 -14.6 0 -14.3 -14.6 04/16/2005 21:20:00 12.7 1.3 16.1 9.1 12.6 1.3 16.1 9.5 0.4 0 0.4 0.4 354 5 352 305 12 0 12 0 -14.8 0 -14.6 -14.8 04/16/2005 21:30:00 12.1 1.4 15.3 9.1 11.9 1.3 15.3 9.1 0.4 0 0.4 0.4 357 7 351 305 11 0 12 0 -14.8 0 -14.6 -15 04/16/2005 21:40:00 12.2 1.1 14.9 8 12.3 1.2 15.3 8 0.4 0 0.4 0.4 356 6 358 305 11 0 11 0 -14.9 0 -14.6 -15 04/16/2005 21:50:00 13.2 1.3 16.1 9.5 13.3 1.5 16.1 9.9 0.4 0 0.4 0.4 352 6 350 305 11 0 11 0 -14.9 0.1 -14.6 -15 04/16/2005 22:00:00 13.2 1.1 15.6 9.9 13.2 1.2 15.6 9.9 0.4 0 0.4 0.4 355 6 352 305 11 0 11 0 -15 0 -14.8 -15 04/16/2005 22:10:00 14.6 1.3 16.8 10.3 14.6 1.3 17.6 10.3 0.4 0 0.4 0.4 354 4 352 305 11 0 11 0 -15.1 0.1 -14.8 -15.4 04/16/2005 22:20:00 12.4 2.2 17.2 7.6 12.3 2.1 16.1 8.4 0.4 0 0.4 0.4 0 6 355 305 11 0 11 0 -15.1 0.1 -14.6 -15.2 04/16/2005 22:30:00 13.2 1.5 16.4 9.9 13.3 1.5 16.4 9.9 0.4 0 0.4 0.4 358 6 359 305 11 0 11 0 -15.1 0 -14.8 -15.2 04/16/2005 22:40:00 11.9 1.3 15.3 9.1 11.8 1.4 15.3 8.4 0.4 0 0.4 0.4 0 6 351 305 11 0 11 0 -14.8 0 -14.6 -15 04/16/2005 22:50:00 10.6 1.4 14.1 7.2 10.5 1.5 14.1 6.8 0.4 0 0.4 0.4 9 7 12 305 11 0 11 0 -14.9 0.1 -14.6 -15 04/16/2005 23:00:00 12 1.5 15.3 7.6 11.9 1.5 15.3 8 0.4 0 0.4 0.4 5 8 359 305 11 0 11 0 -15 0 -14.8 -15 04/16/2005 23:10:00 11.4 1.3 14.1 8.4 11.3 1.2 14.5 8.4 0.4 0 0.4 0.4 7 6 6 305 11 0 11 0 -14.9 0 -14.6 -15 04/16/2005 23:20:00 12.8 1 15.3 9.1 12.7 1.1 15.3 9.5 0.4 0 0.4 0.4 2 6 358 305 11 0 11 0 -14.9 0 -14.6 -15 04/16/2005 23:30:00 13.9 1.1 16.1 11.1 13.9 1 16.4 10.3 0.4 0 0.4 0.4 0 5 353 305 11 0 11 0 -14.8 0 -14.6 -15 04/16/2005 23:40:00 13 1.3 16.4 9.5 13.1 1.4 16.1 9.9 0.4 0 0.4 0.4 4 5 8 305 11 0 11 0 -14.8 0 -14.6 -15 04/16/2005 23:50:00 12 1.1 14.1 9.5 12 1.1 14.1 9.1 0.4 0 0.4 0.4 9 5 7 305 11 0 11 0 -14.9 0 -14.6 -15 04/17/2005 00:00:00 10.9 1 13 8 10.7 1 13 8 0.4 0 0.4 0.4 11 5 12 305 11 0 11 0 -14.9 0 -14.4 -15 04/17/2005 00:10:00 10.6 1.1 12.6 7.2 10.4 1.2 12.6 7.2 0.4 0 0.4 0.4 11 5 14 305 11 0 11 0 -14.8 0 -14.6 -15 04/17/2005 00:20:00 11.4 0.9 13.3 9.1 11.2 1 13.7 8.4 0.4 0 0.4 0.4 8 4 6 305 11 0 11 0 -14.7 0 -14.4 -14.8 04/17/2005 00:30:00 10.1 1.3 13 6.8 10.1 1.2 12.6 7.2 0.4 0 0.4 0.4 5 5 4 305 11 0 11 0 -14.7 0 -14.4 -14.8 04/17/2005 00:40:00 11 1.1 13.3 8 11 1 13.7 8.4 0.4 0 0.4 0.4 4 5 15 305 11 0 11 0 -14.6 0 -14.3 -14.6 04/17/2005 00:50:00 11.2 1.2 13.7 7.6 11.1 1.2 13.3 7.6 0.4 0 0.4 0.4 5 6 0 305 11 0 11 0 -14.7 0 -14.3 -14.6 04/17/2005 01:00:00 10.7 1.2 13.7 7.2 10.6 1.2 13.7 7.6 0.4 0 0.4 0.4 11 5 5 305 11 0 11 0 -14.7 0 -14.4 -14.6 04/17/2005 01:10:00 9.2 1.1 11.5 6.5 9.1 1.1 11.5 6.8 0.4 0 0.4 0.4 14 8 17 305 11 0 11 0 -14.7 0 -14.4 -14.8 04/17/2005 01:20:00 8.3 0.7 9.9 6.5 8.2 0.7 10.3 6.5 0.4 0 0.4 0.4 16 5 22 305 11 0 11 0 -14.9 0.1 -14.6 -15 04/17/2005 01:30:00 7.9 0.7 9.5 6.5 7.8 0.8 9.5 5.7 0.4 0 0.4 0.4 24 5 23 305 11 0 11 0 -15.1 0 -14.6 -15 04/17/2005 01:40:00 7.6 0.7 9.1 6.1 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 28 5 26 305 11 0 11 0 -15.1 0.1 -14.6 -15.2 04/17/2005 01:50:00 6.7 0.6 8.4 5.3 6.6 0.7 8 5.3 0.4 0 0.4 0.4 37 6 39 305 11 0 11 0 -15.2 0 -15 -15.4 04/17/2005 02:00:00 6.3 0.6 7.6 4.9 6.3 0.6 7.6 4.9 0.4 0 0.4 0.4 36 4 37 305 11 0 11 0 -15.3 0 -15 -15.4 04/17/2005 02:10:00 5.7 0.4 6.8 4.9 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 40 5 39 305 11 0 11 0 -15.3 0 -15 -15.6 04/17/2005 02:20:00 5.6 0.5 6.5 4.2 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 41 5 38 305 11 0 11 0 -15.3 0 -15 -15.4 04/17/2005 02:30:00 6.4 0.9 8.4 4.6 6.4 0.9 8 4.6 0.4 0 0.4 0.4 40 5 44 305 11 0 11 0 -15.3 0 -15 -15.4 04/17/2005 02:40:00 6.4 0.6 8 4.9 6.4 0.7 8 4.6 0.4 0 0.4 0.4 37 6 32 305 10 0 11 0 -15.4 0.1 -15 -15.6 04/17/2005 02:50:00 5.7 0.6 7.2 4.6 5.7 0.6 7.2 4.6 0.4 0 0.4 0.4 38 5 41 305 10 0 10 0 -15.7 0.1 -15.2 -15.8 04/17/2005 03:00:00 4.8 0.4 6.1 3.8 4.7 0.4 5.7 3.8 0.4 0 0.4 0.4 32 5 32 305 10 0 10 0 -15.8 0 -15.6 -16 04/17/2005 03:10:00 4.6 0.4 5.7 3.8 4.5 0.4 5.7 3.8 0.4 0 0.4 0.4 31 6 34 305 9 0 9 0 -15.8 0 -15.6 -15.8 04/17/2005 03:20:00 4.5 0.4 6.1 3.4 4.4 0.4 5.3 3 0.4 0 0.4 0.4 34 6 31 305 9 0 9 0 -15.8 0 -15.4 -16 04/17/2005 03:30:00 5.1 0.6 7.2 3.8 4.8 0.6 6.8 3.4 0.4 0 0.4 0.4 27 5 19 305 9 0 9 0 -15.6 0 -15.4 -15.8 04/17/2005 03:40:00 6.3 0.4 7.6 5.3 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 20 3 18 305 9 0 9 0 -15.1 0.1 -14.8 -15.6 04/17/2005 03:50:00 6.3 0.5 7.6 4.9 6.2 0.5 7.6 4.9 0.4 0 0.4 0.4 20 3 18 305 9 0 9 0 -15 0 -14.6 -15 04/17/2005 04:00:00 5.3 0.5 6.5 4.2 5.2 0.6 6.5 3.8 0.4 0 0.4 0.4 17 4 13 305 9 0 9 0 -14.9 0 -14.6 -15 04/17/2005 04:10:00 5 1 6.5 3 4.9 0.9 6.5 3 0.4 0 0.4 0.4 20 8 15 305 10 0 9 0 -14.9 0 -14.6 -15 04/17/2005 04:20:00 4.6 0.7 6.1 3 4.6 0.8 6.1 3 0.4 0 0.4 0.4 24 9 23 305 10 0 10 0 -14.9 0 -14.6 -15 04/17/2005 04:30:00 4.6 0.4 5.7 3.8 4.6 0.4 5.7 3.8 0.4 0 0.4 0.4 16 4 10 305 10 0 10 0 -14.8 0 -14.6 -15 04/17/2005 04:40:00 3.4 1 5.3 1.9 3.5 0.9 5.3 1.9 0.4 0 0.4 0.4 31 9 25 305 10 0 10 0 -14.8 0 -14.6 -14.8 04/17/2005 04:50:00 5.8 1.9 9.9 2.3 5.9 1.8 9.9 2.6 0.4 0 0.4 0.4 358 9 354 305 10 0 11 0 -14.4 0.3 -13.7 -15 04/17/2005 05:00:00 9.8 0.9 11.8 7.6 9.8 1 12.2 7.2 0.4 0 0.4 0.4 351 3 351 305 11 0 11 0 -13.9 0 -13.5 -14.1 04/17/2005 05:10:00 10.4 1 11.8 7.6 10.5 1 12.2 8 0.4 0 0.4 0.4 352 3 350 305 11 0 11 0 -14 0.1 -13.7 -14.3 04/17/2005 05:20:00 9.8 1 11.8 7.2 9.8 1 11.8 7.6 0.4 0 0.4 0.4 353 4 353 305 11 0 11 0 -14 0 -13.7 -14.3 04/17/2005 05:30:00 9.2 0.9 11.1 6.5 9.2 1 11.5 6.5 0.4 0 0.4 0.4 351 3 344 305 11 0 11 0 -14.1 0 -13.7 -14.3 04/17/2005 05:40:00 9.9 0.8 11.8 8.4 9.8 0.8 11.5 7.6 0.4 0 0.4 0.4 353 4 355 305 11 0 11 0 -14.2 0 -13.7 -14.3 04/17/2005 05:50:00 9.1 1.2 11.5 5.7 9 1.2 11.1 5.7 0.4 0 0.4 0.4 352 4 353 305 11 0 11 0 -14.3 0 -14.1 -14.4 04/17/2005 06:00:00 9.1 1.2 11.1 5.7 9 1.2 11.1 6.1 0.4 0 0.4 0.4 354 5 355 305 11 0 11 0 -14.3 0 -14.1 -14.6 04/17/2005 06:10:00 8.9 0.8 11.5 6.8 8.8 0.8 11.5 6.8 0.4 0 0.4 0.4 355 4 351 305 11 0 11 0 -14.4 0 -14.1 -14.6 04/17/2005 06:20:00 9.9 0.8 11.8 7.6 10 0.8 11.8 7.2 0.4 0 0.4 0.4 353 3 352 305 11 0 11 0 -14.3 0 -13.9 -14.4 04/17/2005 06:30:00 10.3 0.9 12.6 7.6 10.2 1 12.2 7.6 0.4 0 0.4 0.4 355 3 0 305 11 0 11 0 -14.3 0 -13.9 -14.4 04/17/2005 06:40:00 10.1 1.1 12.2 7.6 10 1.1 12.2 6.8 0.4 0 0.4 0.4 358 5 359 305 11 0 11 0 -14.3 0 -13.9 -14.4 04/17/2005 06:50:00 10 0.8 11.8 7.6 9.8 0.9 11.8 6.8 0.4 0 0.4 0.4 359 5 356 305 11 0 11 0 -14.3 0 -14.1 -14.4 04/17/2005 07:00:00 9.1 1 11.1 6.8 9.1 1 11.1 6.5 0.4 0 0.4 0.4 8 6 12 305 11 0 11 0 -14.2 0 -13.7 -14.3 04/17/2005 07:10:00 9.4 0.9 11.8 7.2 9.2 1 11.5 6.8 0.4 0 0.4 0.4 11 5 15 305 11 0 11 0 -14.2 0 -13.7 -14.4 04/17/2005 07:20:00 8.4 1.2 11.1 5.7 8.3 1.3 11.5 5.7 0.4 0 0.4 0.4 8 6 0 305 11 0 11 0 -14.2 0 -13.9 -14.4 04/17/2005 07:30:00 8.5 1.2 11.1 5.7 8.5 1.2 11.1 6.1 0.4 0 0.4 0.4 9 5 14 305 11 0 11 0 -14.2 0 -13.7 -14.3 04/17/2005 07:40:00 8.9 1 11.1 6.5 8.9 1.1 11.1 6.5 0.4 0 0.4 0.4 6 5 2 305 11 0 11 0 -14.1 0 -13.7 -14.3 04/17/2005 07:50:00 9.8 1 12.2 7.2 9.8 1 12.2 7.6 0.4 0 0.4 0.4 5 5 17 305 11 0 11 0 -14.1 0.1 -13.7 -14.3 04/17/2005 08:00:00 9.7 1.2 12.6 6.5 9.6 1.1 12.2 6.8 0.4 0 0.4 0.4 5 6 359 305 11 0 11 0 -14 0.1 -13.7 -14.3 04/17/2005 08:10:00 10.3 0.9 12.2 7.2 10.4 1 12.6 6.8 0.4 0 0.4 0.4 3 6 7 305 12 0 12 0 -14 0.1 -13.7 -14.3 04/17/2005 08:20:00 9.9 1 12.2 6.8 10 1.1 12.6 7.2 0.4 0 0.4 0.4 7 5 2 305 12 0 12 0 -14 0.1 -13.7 -14.3 04/17/2005 08:30:00 10 1.1 12.6 7.2 10 1.1 13 7.6 0.4 0 0.4 0.4 8 5 5 305 12 0 12 0 -13.8 0.1 -13.3 -14.3 04/17/2005 08:40:00 10.9 1 13.3 8.4 10.9 1 13 8.8 0.4 0 0.4 0.4 5 5 6 305 12 0 12 0 -13.7 0 -13.3 -13.9 04/17/2005 08:50:00 10.1 1.3 12.6 7.2 10 1.3 13 6.8 0.4 0 0.4 0.4 7 6 6 305 12 0 12 0 -13.7 0 -13.3 -13.7 04/17/2005 09:00:00 10.4 1 12.2 7.2 10.3 1 12.2 7.6 0.4 0 0.4 0.4 9 4 7 305 13 0 13 0 -13.5 0.1 -13.1 -13.7 04/17/2005 09:10:00 10.5 1.1 13.3 6.8 10.5 1.1 13 7.6 0.4 0 0.4 0.4 357 8 354 305 13 0 13 0 -13.4 0.1 -12.9 -13.7 04/17/2005 09:20:00 10.5 1 13 7.6 10.4 1 13 7.6 0.4 0 0.4 0.4 357 5 358 305 12 0 12 0 -13.6 0 -13.3 -13.7 04/17/2005 09:30:00 10.5 1.1 12.6 7.2 10.6 1.1 13 6.5 0.4 0 0.4 0.4 0 6 359 305 13 0 13 0 -13.5 0.1 -13.1 -13.7 04/17/2005 09:40:00 10.1 1.4 13.3 6.8 10.2 1.4 12.6 7.2 0.4 0 0.4 0.4 0 5 359 305 13 0 13 0 -13.5 0.1 -12.9 -13.7 04/17/2005 09:50:00 10.8 1.2 13.3 8 10.7 1.2 13.3 7.6 0.4 0 0.4 0.4 3 5 1 305 14 0 14 0 -13.3 0 -12.9 -13.7 04/17/2005 10:00:00 10.2 1.3 12.6 7.2 10.2 1.2 12.6 7.6 0.4 0 0.4 0.4 2 6 1 305 14 0 14 0 -13.4 0.1 -12.9 -13.5 04/17/2005 10:10:00 11.1 1 13 8.8 11 1.1 13.3 8.8 0.4 0 0.4 0.4 7 4 3 305 13 0 13 0 -13.5 0.1 -12.9 -13.7 04/17/2005 10:20:00 11 1 13.3 8.8 11 1 14.1 8.4 0.4 0 0.4 0.4 6 5 5 305 14 0 14 0 -13.2 0.1 -12.7 -13.3 04/17/2005 10:30:00 11.1 1 14.1 8.4 11 1.1 14.5 8.4 0.4 0 0.4 0.4 3 6 6 305 15 0 15 0 -13.2 0.1 -12.7 -13.5 04/17/2005 10:40:00 10.8 1.3 13.3 6.8 10.6 1.4 13.3 6.8 0.4 0 0.4 0.4 6 5 14 305 15 0 15 0 -13.1 0.1 -12.5 -13.3 04/17/2005 10:50:00 11.1 1.4 13.7 8.4 11.1 1.5 14.1 7.6 0.4 0 0.4 0.4 5 6 356 305 15 0 15 0 -13 0.1 -12.5 -13.3 04/17/2005 11:00:00 11.5 1.2 13.7 8.4 11.5 1.2 14.1 8 0.4 0 0.4 0.4 3 5 358 305 16 0 16 0 -12.9 0.2 -12.5 -13.3 04/17/2005 11:10:00 10.6 1.2 13.3 7.6 10.6 1.2 13.7 7.2 0.4 0 0.4 0.4 7 6 1 305 16 0 16 0 -12.8 0.1 -12.5 -13.1 04/17/2005 11:20:00 13 1 15.3 10.3 13 1.2 15.3 9.5 0.4 0 0.4 0.4 5 3 8 305 17 0 17 0 -12.9 0.1 -12.5 -13.1 04/17/2005 11:30:00 12.6 1 14.5 9.5 12.5 1.1 14.5 9.1 0.4 0 0.4 0.4 6 4 2 305 16 0 16 0 -12.9 0.1 -12.5 -13.1 04/17/2005 11:40:00 11.9 0.9 13.7 9.1 11.9 1 14.1 8.8 0.4 0 0.4 0.4 4 5 8 305 17 0 16 0 -12.9 0.1 -12.5 -13.1 04/17/2005 11:50:00 10.9 1.1 13 8 10.9 1.1 13.3 8 0.4 0 0.4 0.4 3 6 9 305 17 0 18 0 -12.7 0.1 -12.3 -13.1 04/17/2005 12:00:00 11.8 0.7 13.7 9.9 11.8 0.8 13.7 9.9 0.4 0 0.4 0.4 3 5 11 305 17 0 18 0 -12.8 0.1 -12.3 -13.1 04/17/2005 12:10:00 11.7 0.8 13.3 8.8 11.7 0.8 13.7 9.1 0.4 0 0.4 0.4 2 5 6 305 17 0 18 0 -12.8 0.1 -12.3 -12.9 04/17/2005 12:20:00 11.1 0.9 13.3 8.4 11.1 1 13.3 8 0.4 0 0.4 0.4 0 4 0 305 17 0 17 0 -12.6 0.1 -12.3 -12.9 04/17/2005 12:30:00 10.7 1 12.6 7.6 10.7 1.1 13 8 0.4 0 0.4 0.4 358 5 358 305 17 0 17 0 -12.6 0.1 -12.1 -12.9 04/17/2005 12:40:00 10.4 1.2 12.6 6.8 10.5 1.3 13 6.8 0.4 0 0.4 0.4 3 5 3 305 17 0 17 0 -12.4 0.2 -11.9 -12.7 04/17/2005 12:50:00 10.9 0.7 12.2 8.4 11 0.8 12.6 8.8 0.4 0 0.4 0.4 3 4 2 305 18 0 18 0 -12.2 0.1 -11.7 -12.5 04/17/2005 13:00:00 10.3 1.1 12.6 7.6 10.3 1 13 7.2 0.4 0 0.4 0.4 2 5 1 305 19 0 19 0 -12 0.1 -11.5 -12.3 04/17/2005 13:10:00 11.1 1 13 8.4 11.1 1 13.3 8 0.4 0 0.4 0.4 3 5 4 305 20 0 20 0 -12 0 -11.7 -12.3 04/17/2005 13:20:00 11.3 0.9 13.3 8.4 11.3 1 13.3 8.8 0.4 0 0.4 0.4 3 4 6 305 20 0 20 0 -12.1 0 -11.7 -12.5 04/17/2005 13:30:00 10.9 1.1 13.3 7.2 11 1.1 13.3 7.6 0.4 0 0.4 0.4 1 4 1 305 20 0 20 0 -12 0.1 -11.5 -12.1 04/17/2005 13:40:00 11.3 0.9 13 8.4 11.3 0.9 13 8.8 0.4 0 0.4 0.4 1 5 0 305 20 0 20 0 -12 0 -11.7 -12.1 04/17/2005 13:50:00 10.5 1 12.6 7.2 10.4 1 12.6 8 0.4 0 0.4 0.4 7 6 16 305 20 0 21 0 -11.7 0.1 -11.3 -12.1 04/17/2005 14:00:00 10.8 0.9 12.6 7.6 10.9 1 13 7.6 0.4 0 0.4 0.4 4 5 356 305 21 0 21 0 -11.6 0 -11.3 -11.7 04/17/2005 14:10:00 11.4 0.9 13 8.8 11.6 1 13.7 8.8 0.4 0 0.4 0.4 2 4 4 305 21 0 21 0 -11.5 0 -11.3 -11.7 04/17/2005 14:20:00 11 0.9 13 8.4 11 1 13 8.8 0.4 0 0.4 0.4 1 4 4 305 21 0 21 0 -11.4 0 -10.9 -11.5 04/17/2005 14:30:00 10.9 0.8 12.6 8.4 11 0.8 13 8.8 0.4 0 0.4 0.4 4 4 11 305 22 0 22 0 -11.2 0.1 -10.7 -11.5 04/17/2005 14:40:00 10 0.8 11.8 7.6 10.1 0.8 11.8 7.6 0.4 0 0.4 0.4 3 6 357 305 23 0 22 0 -11 0.1 -10.4 -11.3 04/17/2005 14:50:00 10.2 0.9 12.2 7.2 10.1 1 12.2 7.2 0.4 0 0.4 0.4 1 5 359 305 23 0 24 0 -11 0.1 -10.4 -11.3 04/17/2005 15:00:00 10 0.8 11.8 8 10.1 0.8 12.6 8.4 0.4 0 0.4 0.4 4 4 12 305 24 0 24 0 -10.9 0 -10.4 -11.1 04/17/2005 15:10:00 10 1.1 12.2 7.2 10 1.1 13 7.2 0.4 0 0.4 0.4 1 5 354 305 24 0 24 0 -10.9 0.1 -10.4 -11.3 04/17/2005 15:20:00 9.9 1 13 7.6 10 1 12.2 7.6 0.4 0 0.4 0.4 1 5 9 305 24 0 24 0 -10.9 0 -10.4 -11.3 04/17/2005 15:30:00 10.4 0.9 12.2 7.6 10.5 1 12.2 7.6 0.4 0 0.4 0.4 356 4 355 305 23 0 23 0 -10.9 0.1 -10.4 -11.3 04/17/2005 15:40:00 10.8 0.8 12.6 8.4 10.7 0.9 13 7.6 0.4 0 0.4 0.4 0 4 358 305 23 0 24 0 -10.8 0.1 -10.2 -11.1 04/17/2005 15:50:00 10.6 1.1 12.6 7.2 10.6 1.1 13 7.6 0.4 0 0.4 0.4 4 5 10 305 25 0 25 0 -10.6 0.1 -10.2 -10.9 04/17/2005 16:00:00 10.9 1 13.3 8.4 11.1 1 13 8.4 0.4 0 0.4 0.4 0 5 355 305 25 0 25 0 -10.5 0.1 -10 -10.9 04/17/2005 16:10:00 11 0.9 13 8 11 0.9 13 8 0.4 0 0.4 0.4 2 5 17 305 25 0 25 0 -10.4 0.1 -10 -10.9 04/17/2005 16:20:00 10.8 1.1 13 8 10.8 1.2 13.3 8 0.4 0 0.4 0.4 358 5 354 305 25 0 25 0 -10.4 0.1 -9.8 -10.9 04/17/2005 16:30:00 11.4 1.2 13.7 8.8 11.4 1.3 14.1 8.4 0.4 0 0.4 0.4 5 5 2 305 24 0 25 0 -10.8 0.1 -10.4 -10.9 04/17/2005 16:40:00 10.7 1 12.6 8 10.6 1 12.6 8 0.4 0 0.4 0.4 3 5 5 305 24 0 24 0 -10.5 0.1 -10 -10.9 04/17/2005 16:50:00 10.5 1.2 13 7.6 10.3 1.2 13 7.6 0.4 0 0.4 0.4 8 5 8 305 24 0 24 0 -10.9 0.1 -10 -11.3 04/17/2005 17:00:00 11.1 0.9 13 8.8 11.1 1 13.3 8.8 0.4 0 0.4 0.4 3 5 357 305 23 0 23 0 -11 0 -10.4 -11.3 04/17/2005 17:10:00 10.4 1.2 13 7.2 10.4 1.2 13 7.6 0.4 0 0.4 0.4 5 5 8 305 22 0 22 0 -11.2 0.2 -10.4 -11.5 04/17/2005 17:20:00 10.9 1 13.3 8.8 10.9 0.9 13.3 8.8 0.4 0 0.4 0.4 2 5 358 305 22 0 22 0 -11 0.1 -10.4 -11.3 04/17/2005 17:30:00 10.8 1.1 13 7.6 10.9 1.2 13 7.6 0.4 0 0.4 0.4 1 4 3 305 22 0 22 0 -11 0.1 -10.4 -11.3 04/17/2005 17:40:00 10.5 1 12.6 7.6 10.6 1.1 13 8 0.4 0 0.4 0.4 1 5 2 305 22 0 21 0 -11.1 0.2 -10.4 -11.5 04/17/2005 17:50:00 10.9 1.2 13.3 7.2 10.9 1.3 13.7 7.6 0.4 0 0.4 0.4 2 5 5 305 22 0 22 0 -10.9 0.1 -10.4 -11.3 04/17/2005 18:00:00 10.7 1.3 13.3 7.2 10.8 1.2 13.3 7.6 0.4 0 0.4 0.4 1 5 356 305 21 0 22 0 -11.1 0 -10.9 -11.3 04/17/2005 18:10:00 10.2 1 12.6 7.2 10.3 1 12.6 7.6 0.4 0 0.4 0.4 1 6 6 305 21 0 21 0 -10.9 0 -10.4 -11.1 04/17/2005 18:20:00 9.4 0.9 11.8 7.6 9.3 0.9 11.8 7.6 0.4 0 0.4 0.4 8 8 357 305 21 0 21 0 -11.1 0 -10.7 -11.3 04/17/2005 18:30:00 9.7 1 11.8 6.8 9.7 1 12.6 6.8 0.4 0 0.4 0.4 6 5 357 305 20 0 20 0 -11.2 0 -10.9 -11.3 04/17/2005 18:40:00 10.4 1 13 7.6 10.3 1.1 13 8 0.4 0 0.4 0.4 6 5 9 305 20 0 19 0 -11.1 0.1 -10.9 -11.5 04/17/2005 18:50:00 9.9 1.3 12.6 6.8 9.8 1.3 13 6.8 0.4 0 0.4 0.4 10 5 3 305 19 0 19 0 -11.3 0.1 -10.9 -11.5 04/17/2005 19:00:00 10.2 1.5 13 6.5 9.9 1.5 12.6 5.7 0.4 0 0.4 0.4 14 5 18 305 19 0 19 0 -11.4 0 -11.1 -11.5 04/17/2005 19:10:00 11.6 1.2 13.7 7.6 11.5 1.3 13.7 8 0.4 0 0.4 0.4 12 4 8 305 19 0 19 0 -11.3 0.1 -10.9 -11.5 04/17/2005 19:20:00 10.4 1.2 13 7.6 10.2 1.2 12.6 7.6 0.4 0 0.4 0.4 10 8 16 305 19 0 19 0 -11.1 0.1 -10.7 -11.5 04/17/2005 19:30:00 10.5 1.1 13 8 10.4 1.1 13.3 7.6 0.4 0 0.4 0.4 13 5 13 305 19 0 18 0 -11.4 0.1 -10.9 -11.5 04/17/2005 19:40:00 10.9 0.8 13 8.8 10.9 0.8 13 8.8 0.4 0 0.4 0.4 11 5 10 305 18 0 18 0 -11.5 0 -11.3 -11.7 04/17/2005 19:50:00 10.2 1 13 7.6 10.1 1.1 13 7.2 0.4 0 0.4 0.4 18 5 22 305 18 0 18 0 -11.5 0 -11.3 -11.7 04/17/2005 20:00:00 9.6 1 12.6 7.2 9.5 1 12.2 7.2 0.4 0 0.4 0.4 15 5 19 305 17 0 17 0 -11.5 0 -11.3 -11.7 04/17/2005 20:10:00 10.6 1 12.6 7.2 10.6 1.1 13 7.2 0.4 0 0.4 0.4 9 6 11 305 17 0 17 0 -11.5 0 -11.3 -11.7 04/17/2005 20:20:00 10.5 0.9 12.6 7.6 10.5 1 13 7.6 0.4 0 0.4 0.4 8 6 8 305 17 0 17 0 -11.5 0 -11.3 -11.7 04/17/2005 20:30:00 10.8 0.9 13 8 10.8 0.9 12.6 8 0.4 0 0.4 0.4 11 5 16 305 17 0 17 0 -11.6 0 -11.3 -11.7 04/17/2005 20:40:00 9.9 1 13 7.6 9.8 0.9 11.8 8 0.4 0 0.4 0.4 19 7 22 305 16 0 16 0 -11.6 0 -11.3 -11.9 04/17/2005 20:50:00 9.9 1 12.2 7.6 9.8 1 12.2 6.8 0.4 0 0.4 0.4 13 5 21 305 16 0 16 0 -11.7 0 -11.3 -11.9 04/17/2005 21:00:00 10.2 1 13 7.2 10 1.1 12.6 6.8 0.4 0 0.4 0.4 16 7 6 305 16 0 16 0 -11.6 0 -11.3 -11.9 04/17/2005 21:10:00 10.3 1 12.6 7.6 10.2 1 12.6 7.2 0.4 0 0.4 0.4 15 6 11 305 16 0 16 0 -11.6 0 -11.3 -11.7 04/17/2005 21:20:00 10.6 0.9 12.2 8 10.4 1 12.2 8.4 0.4 0 0.4 0.4 19 5 10 305 16 0 16 0 -11.7 0 -11.5 -11.9 04/17/2005 21:30:00 10.7 1 13.3 8 10.5 1 13 8 0.4 0 0.4 0.4 19 5 12 305 16 0 16 0 -11.6 0 -11.3 -11.7 04/17/2005 21:40:00 10.8 1 13 8 10.6 1 13.3 8 0.4 0 0.4 0.4 18 5 22 305 16 0 15 0 -11.6 0 -11.3 -11.9 04/17/2005 21:50:00 11.3 0.9 13.7 9.1 11.1 1 13.3 8.8 0.4 0 0.4 0.4 12 6 22 305 16 0 15 0 -11.4 0.1 -10.9 -11.7 04/17/2005 22:00:00 11.4 1.1 14.1 7.6 11.2 1.1 14.1 8 0.4 0 0.4 0.4 17 5 21 305 16 0 16 0 -11.4 0 -11.1 -11.5 04/17/2005 22:10:00 11.2 1.2 13.7 8 11.1 1.3 13.7 7.6 0.4 0 0.4 0.4 17 5 17 305 16 0 15 0 -11.4 0.1 -10.9 -11.5 04/17/2005 22:20:00 10.9 1 13.7 7.6 10.8 1.1 13.3 7.6 0.4 0 0.4 0.4 12 6 18 305 16 0 16 0 -11.5 0 -11.3 -11.7 04/17/2005 22:30:00 11.2 1 14.1 8.8 11.1 1 14.1 8.4 0.4 0 0.4 0.4 11 6 21 305 15 0 15 0 -11.5 0 -11.3 -11.7 04/17/2005 22:40:00 10.4 1 13 8 10.3 1 13 8 0.4 0 0.4 0.4 10 6 9 305 15 0 15 0 -11.5 0 -11.3 -11.7 04/17/2005 22:50:00 11.3 1.3 14.1 7.6 11.2 1.3 13.7 7.6 0.4 0 0.4 0.4 13 5 16 305 15 0 16 0 -11.4 0 -11.1 -11.7 04/17/2005 23:00:00 11.2 1.2 13.7 8 11 1.2 13.7 8 0.4 0 0.4 0.4 12 7 21 305 16 0 15 0 -11.4 0 -10.9 -11.5 04/17/2005 23:10:00 10.6 1.3 13.7 7.6 10.5 1.2 13.3 7.6 0.4 0 0.4 0.4 13 7 12 305 16 0 15 0 -11.3 0.1 -10.9 -11.5 04/17/2005 23:20:00 11 1.1 13.3 8 10.9 1.1 13 8 0.4 0 0.4 0.4 13 5 18 305 16 0 15 0 -11.2 0 -10.9 -11.5 04/17/2005 23:30:00 9.9 1.1 12.6 6.8 9.8 1.1 13 7.2 0.4 0 0.4 0.4 9 6 12 305 16 0 15 0 -11.2 0 -10.9 -11.3 04/17/2005 23:40:00 10.2 0.9 12.2 7.6 10.1 1 12.2 7.6 0.4 0 0.4 0.4 7 5 9 305 16 0 16 0 -11.1 0 -10.9 -11.3 04/17/2005 23:50:00 10.8 1 13.7 8 10.7 1.1 13.3 7.6 0.4 0 0.4 0.4 6 5 13 305 16 0 16 0 -11.1 0 -10.7 -11.3 04/18/2005 00:00:00 8.1 1 11.8 6.1 8 1.1 12.6 6.1 0.4 0 0.4 0.4 43 15 1 305 16 0 16 0 -11.7 0.4 -10.7 -12.3 04/18/2005 00:10:00 6.9 0.6 8.4 4.9 6.7 0.6 8.4 4.9 0.4 0 0.4 0.4 45 6 53 305 15 0 15 0 -12.3 0.1 -11.9 -12.5 04/18/2005 00:20:00 6.3 0.6 7.6 5.3 6.2 0.6 7.6 4.6 0.4 0 0.4 0.4 48 6 50 305 15 0 15 0 -12.5 0 -12.1 -12.5 04/18/2005 00:30:00 6.9 0.9 8.8 4.6 6.8 0.8 8.8 4.6 0.4 0 0.4 0.4 36 8 22 305 15 0 14 0 -12.3 0.2 -11.7 -12.5 04/18/2005 00:40:00 7.2 0.7 8.8 5.7 7.1 0.8 8.8 5.3 0.4 0 0.4 0.4 34 5 32 305 15 0 15 0 -12 0 -11.7 -12.1 04/18/2005 00:50:00 6.9 0.9 11.1 5.3 6.6 1 10.7 4.9 0.4 0 0.4 0.4 34 9 17 305 15 0 14 0 -12.1 0.1 -11.7 -12.3 04/18/2005 01:00:00 7.4 0.9 9.5 4.6 7.2 0.9 9.5 4.6 0.4 0 0.4 0.4 30 8 23 305 15 0 15 0 -11.7 0.1 -11.5 -12.1 04/18/2005 01:10:00 7.2 1.8 12.2 4.6 7 1.8 11.8 4.6 0.4 0 0.4 0.4 39 12 22 305 15 0 14 0 -12.2 0.2 -11.5 -12.5 04/18/2005 01:20:00 10 1.1 11.8 6.1 9.8 1.1 12.2 6.8 0.4 0 0.4 0.4 21 8 23 305 15 0 15 0 -11.5 0 -11.1 -11.7 04/18/2005 01:30:00 9.1 1.2 11.8 6.5 9 1.2 11.8 6.5 0.4 0 0.4 0.4 11 6 13 305 15 0 15 0 -11.4 0 -10.9 -11.7 04/18/2005 01:40:00 9.5 1 11.8 7.2 9.5 1 11.8 6.8 0.4 0 0.4 0.4 12 5 13 305 15 0 15 0 -11.5 0 -11.1 -11.7 04/18/2005 01:50:00 10 0.9 11.8 7.2 9.9 0.9 12.6 8 0.4 0 0.4 0.4 9 4 16 305 15 0 15 0 -11.5 0 -11.3 -11.7 04/18/2005 02:00:00 10.2 1 12.2 7.6 10.1 1 12.6 7.6 0.4 0 0.4 0.4 9 4 10 305 15 0 15 0 -11.6 0 -11.3 -11.9 04/18/2005 02:10:00 10.3 1 12.6 7.2 10.1 1.1 13 6.8 0.4 0 0.4 0.4 12 4 12 305 15 0 15 0 -11.6 0.1 -11.3 -12.1 04/18/2005 02:20:00 9.7 0.8 11.8 7.6 9.5 0.8 11.8 6.8 0.4 0 0.4 0.4 9 4 10 305 14 0 15 0 -11.8 0.1 -11.5 -12.1 04/18/2005 02:30:00 9.9 1 11.8 7.2 9.8 1 11.8 7.2 0.4 0 0.4 0.4 9 7 5 305 14 0 14 0 -11.7 0 -11.3 -12.1 04/18/2005 02:40:00 8 0.6 9.5 6.5 7.9 0.6 9.5 5.7 0.4 0 0.4 0.4 33 4 20 305 15 0 14 0 -12.1 0.1 -11.7 -12.5 04/18/2005 02:50:00 7.1 0.6 8.4 5.3 7 0.6 8.4 5.3 0.4 0 0.4 0.4 38 5 38 305 14 0 14 0 -12.4 0.2 -11.7 -12.5 04/18/2005 03:00:00 7.4 0.5 8.4 6.5 7.3 0.5 8.8 6.1 0.4 0 0.4 0.4 39 4 40 305 14 0 14 0 -12.6 0 -12.3 -12.9 04/18/2005 03:10:00 7.1 0.6 8.8 5.3 7 0.6 8.8 5.3 0.4 0 0.4 0.4 33 4 28 305 14 0 14 0 -12.6 0 -12.1 -12.7 04/18/2005 03:20:00 8.2 0.8 10.7 6.5 8 0.8 10.3 5.7 0.4 0 0.4 0.4 33 6 20 305 14 0 14 0 -12.5 0 -12.1 -12.7 04/18/2005 03:30:00 8.1 1.1 11.5 5.7 7.9 1.2 11.5 5.7 0.4 0 0.4 0.4 25 7 15 305 14 0 14 0 -12.5 0 -12.1 -12.5 04/18/2005 03:40:00 9.5 1.3 12.6 6.5 9.3 1.3 12.2 6.1 0.4 0 0.4 0.4 21 8 13 305 14 0 14 0 -12 0 -11.7 -12.3 04/18/2005 03:50:00 9.6 0.9 12.2 7.2 9.5 1 11.5 7.2 0.4 0 0.4 0.4 21 7 23 305 14 0 14 0 -11.9 0 -11.5 -12.1 04/18/2005 04:00:00 9.1 1.3 11.8 6.1 9 1.3 12.6 6.1 0.4 0 0.4 0.4 24 7 31 305 14 0 14 0 -12.1 0.1 -11.5 -12.5 04/18/2005 04:10:00 10.4 1.1 13 6.5 10.2 1.1 13 6.5 0.4 0 0.4 0.4 21 5 20 305 14 0 14 0 -11.9 0.1 -11.5 -12.1 04/18/2005 04:20:00 10 1.2 12.2 6.1 9.9 1.2 11.8 6.5 0.4 0 0.4 0.4 22 5 21 305 14 0 14 0 -11.9 0 -11.5 -12.1 04/18/2005 04:30:00 9.7 0.7 11.5 8 9.5 0.8 11.5 7.6 0.4 0 0.4 0.4 27 5 27 305 14 0 14 0 -12 0 -11.5 -12.1 04/18/2005 04:40:00 9.3 1 11.1 6.8 9.1 1 11.5 6.5 0.4 0 0.4 0.4 27 5 25 305 14 0 14 0 -12 0 -11.7 -12.1 04/18/2005 04:50:00 9.4 1 11.8 7.2 9.3 1 12.6 6.8 0.4 0 0.4 0.4 18 9 10 305 14 0 14 0 -11.9 0.1 -11.5 -12.1 04/18/2005 05:00:00 10.2 0.9 12.2 7.6 10.1 1 12.2 7.2 0.4 0 0.4 0.4 18 7 14 305 14 0 14 0 -11.7 0.1 -11.3 -12.1 04/18/2005 05:10:00 8.9 1 10.7 6.8 8.9 1 11.1 6.5 0.4 0 0.4 0.4 22 5 24 305 14 0 14 0 -11.9 0 -11.5 -12.1 04/18/2005 05:20:00 9.7 1.1 12.6 7.2 9.6 1 12.6 7.2 0.4 0 0.4 0.4 16 6 0 305 14 0 14 0 -11.8 0.1 -11.5 -12.1 04/18/2005 05:30:00 10.7 1 13 7.6 10.6 1 13 8 0.4 0 0.4 0.4 8 5 16 305 14 0 14 0 -11.8 0.1 -11.5 -12.1 04/18/2005 05:40:00 11.8 0.7 13.3 9.1 11.7 0.8 13.7 9.1 0.4 0 0.4 0.4 3 4 6 305 14 0 14 0 -11.9 0.1 -11.5 -12.1 04/18/2005 05:50:00 11.1 0.9 13.7 9.1 11.1 0.9 13.7 8.8 0.4 0 0.4 0.4 4 5 8 305 14 0 14 0 -11.9 0.1 -11.5 -12.1 04/18/2005 06:00:00 11.1 1 13.3 8.8 10.9 1.1 13.3 8 0.4 0 0.4 0.4 8 4 8 305 14 0 14 0 -11.8 0.1 -11.5 -12.1 04/18/2005 06:10:00 9.9 1.2 13.3 7.2 9.8 1.2 13.3 7.2 0.4 0 0.4 0.4 13 6 9 305 14 0 14 0 -11.7 0 -11.3 -11.9 04/18/2005 06:20:00 10.2 1 13 7.6 10.1 1 13 7.6 0.4 0 0.4 0.4 22 6 23 305 14 0 14 0 -11.8 0.1 -11.3 -12.1 04/18/2005 06:30:00 10.9 1.2 13.3 8 10.9 1.3 13.7 7.6 0.4 0 0.4 0.4 12 5 12 305 14 0 14 0 -11.8 0.1 -11.5 -12.1 04/18/2005 06:40:00 10.4 1.1 12.6 7.2 10.4 1.1 12.6 7.6 0.4 0 0.4 0.4 13 6 10 305 14 0 14 0 -11.8 0.1 -11.5 -12.1 04/18/2005 06:50:00 11.2 1 13 8.4 11.1 1 13.3 8.4 0.4 0 0.4 0.4 22 5 26 305 14 0 14 0 -12 0 -11.5 -12.1 04/18/2005 07:00:00 11.2 1 13.7 9.1 10.9 1.1 13.3 8.4 0.4 0 0.4 0.4 24 4 21 305 14 0 14 0 -12.1 0 -11.7 -12.5 04/18/2005 07:10:00 10.7 1 13.3 8.4 10.5 1 13 8.4 0.4 0 0.4 0.4 26 4 22 305 14 0 14 0 -12.2 0 -11.9 -12.5 04/18/2005 07:20:00 11.1 1.1 13.7 8.4 10.8 1.1 13 8 0.4 0 0.4 0.4 26 5 23 305 14 0 14 0 -12.1 0 -11.7 -12.3 04/18/2005 07:30:00 11.4 1 13.7 9.1 11.2 1 13.7 8.8 0.4 0 0.4 0.4 25 4 24 305 14 0 14 0 -12.1 0 -11.7 -12.3 04/18/2005 07:40:00 10.7 1 13.3 8.8 10.4 1 13 8 0.4 0 0.4 0.4 20 5 19 305 14 0 14 0 -12 0 -11.7 -12.3 04/18/2005 07:50:00 10.8 1 13.3 8.4 10.5 1.1 13.3 8 0.4 0 0.4 0.4 19 5 16 305 14 0 14 0 -12.1 0 -11.7 -12.3 04/18/2005 08:00:00 11 1 13.3 8 10.7 1 13 8.4 0.4 0 0.4 0.4 19 5 16 305 14 0 14 0 -12.1 0 -11.7 -12.3 04/18/2005 08:10:00 9.6 1 12.6 6.8 9.4 1 12.2 6.8 0.4 0 0.4 0.4 20 5 18 305 14 0 14 0 -12.1 0 -11.7 -12.3 04/18/2005 08:20:00 10.2 1 12.2 8 10.2 1 12.6 7.6 0.4 0 0.4 0.4 17 5 29 305 14 0 15 0 -11.9 0.1 -11.3 -12.1 04/18/2005 08:30:00 10.3 1.2 12.6 7.2 10.1 1.1 13 6.8 0.4 0 0.4 0.4 16 5 14 305 15 0 15 0 -11.7 0 -11.3 -11.9 04/18/2005 08:40:00 11 1 13.7 8.4 10.8 1 13 8 0.4 0 0.4 0.4 15 5 12 305 15 0 15 0 -11.6 0 -11.1 -11.9 04/18/2005 08:50:00 10.2 1.1 13 7.6 10.1 1.1 13 7.6 0.4 0 0.4 0.4 11 5 5 305 15 0 15 0 -11.5 0 -11.1 -11.7 04/18/2005 09:00:00 10.2 1.2 13 7.2 10.1 1.2 12.6 7.2 0.4 0 0.4 0.4 12 5 10 305 16 0 15 0 -11.4 0.1 -10.9 -11.7 04/18/2005 09:10:00 10.6 1 13 7.6 10.3 1 12.6 8 0.4 0 0.4 0.4 10 5 8 305 16 0 16 0 -11.4 0.1 -10.9 -11.7 04/18/2005 09:20:00 10.6 1 12.6 8 10.5 1 12.6 7.2 0.4 0 0.4 0.4 12 5 1 305 16 0 16 0 -11.3 0.1 -10.9 -11.5 04/18/2005 09:30:00 10.7 0.8 12.6 8.8 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 11 4 13 305 16 0 16 0 -11.2 0.1 -10.9 -11.5 04/18/2005 09:40:00 10.6 1.1 13 8 10.5 1.2 13.3 8 0.4 0 0.4 0.4 15 4 14 305 17 0 16 0 -11.2 0.1 -10.9 -11.5 04/18/2005 09:50:00 10.8 0.9 13 8 10.7 0.9 13 8 0.4 0 0.4 0.4 12 4 9 305 17 0 16 0 -11.2 0.1 -10.7 -11.3 04/18/2005 10:00:00 10.4 0.9 11.8 6.8 10.3 0.9 11.8 7.6 0.4 0 0.4 0.4 14 5 9 305 17 0 16 0 -11 0 -10.4 -11.3 04/18/2005 10:10:00 10.5 0.9 12.2 8 10.4 0.9 12.6 8.4 0.4 0 0.4 0.4 12 5 12 305 17 0 17 0 -10.9 0 -10.4 -11.1 04/18/2005 10:20:00 10.3 1.1 12.6 7.6 10.3 1.1 12.6 7.6 0.4 0 0.4 0.4 12 4 5 305 17 0 18 0 -10.9 0.1 -10.4 -11.3 04/18/2005 10:30:00 10.9 0.8 13 8.4 10.8 0.8 12.6 8 0.4 0 0.4 0.4 13 5 17 305 18 0 18 0 -10.8 0.1 -10.4 -10.9 04/18/2005 10:40:00 10.4 1.1 12.6 7.6 10.3 1.1 12.6 8 0.4 0 0.4 0.4 10 5 7 305 18 0 18 0 -10.7 0.1 -10 -10.9 04/18/2005 10:50:00 10.7 1.2 13 8 10.6 1.2 13.7 8 0.4 0 0.4 0.4 12 5 11 305 18 0 18 0 -10.7 0.1 -10.2 -10.9 04/18/2005 11:00:00 11.4 0.9 13.3 8.8 11.1 1 13.3 8.8 0.4 0 0.4 0.4 15 4 16 305 19 0 19 0 -10.6 0 -10 -10.9 04/18/2005 11:10:00 11.3 0.9 13.3 8.8 11.3 1 13.3 8.4 0.4 0 0.4 0.4 17 5 17 305 19 0 19 0 -10.5 0 -10 -10.9 04/18/2005 11:20:00 11.1 1 13 8 11 1 13 8 0.4 0 0.4 0.4 20 5 22 305 19 0 19 0 -10.4 0 -10 -10.4 04/18/2005 11:30:00 11.1 1.3 14.1 7.6 11.1 1.3 13.7 8 0.4 0 0.4 0.4 17 5 14 305 20 0 19 0 -10.3 0.1 -9.8 -10.4 04/18/2005 11:40:00 11.7 0.9 13.7 9.1 11.4 0.9 13.7 8.8 0.4 0 0.4 0.4 17 4 12 305 20 0 20 0 -10.3 0 -9.8 -10.4 04/18/2005 11:50:00 11.3 1.1 13.3 8.4 11.2 1.1 13.7 8.8 0.4 0 0.4 0.4 17 5 18 305 20 0 20 0 -10.2 0.1 -9.8 -10.4 04/18/2005 12:00:00 11.1 1 13 8.4 11.1 1 13 8 0.4 0 0.4 0.4 16 4 15 305 20 0 20 0 -10.1 0.1 -9.6 -10.4 04/18/2005 12:10:00 10.9 1 13 8 10.7 1.1 13 8 0.4 0 0.4 0.4 18 5 13 305 20 0 20 0 -10 0 -9.6 -10.2 04/18/2005 12:20:00 9.8 1.3 12.6 6.5 9.8 1.3 12.6 6.5 0.4 0 0.4 0.4 16 5 15 305 20 0 20 0 -9.9 0.1 -9.2 -10.2 04/18/2005 12:30:00 10.1 1.1 13 7.6 10.1 1.2 13.3 6.8 0.4 0 0.4 0.4 14 5 18 305 21 0 21 0 -9.8 0 -9.2 -10 04/18/2005 12:40:00 10.5 1 13 7.6 10.4 0.9 13 8.4 0.4 0 0.4 0.4 14 5 10 305 21 0 21 0 -9.8 0.1 -9.2 -10 04/18/2005 12:50:00 10.8 1 12.6 8 10.6 1 12.6 8.4 0.4 0 0.4 0.4 19 6 18 305 21 0 21 0 -9.7 0.1 -9.2 -9.8 04/18/2005 13:00:00 11 1 13.3 8 10.9 1 13.7 8.4 0.4 0 0.4 0.4 21 5 15 305 21 0 21 0 -9.7 0.1 -9.2 -9.8 04/18/2005 13:10:00 11.3 0.9 13.3 8.8 11.3 1 13.7 8.4 0.4 0 0.4 0.4 18 5 18 305 21 0 21 0 -9.5 0.1 -9 -9.8 04/18/2005 13:20:00 11.1 1 13 8 11 1.1 13 7.6 0.4 0 0.4 0.4 21 5 26 305 21 0 21 0 -9.5 0 -9.2 -9.6 04/18/2005 13:30:00 10.5 1.1 12.6 7.6 10.3 1.1 13 8 0.4 0 0.4 0.4 23 5 27 305 21 0 21 0 -9.4 0 -9 -9.6 04/18/2005 13:40:00 10.9 0.8 12.6 8.4 10.9 0.9 12.6 8 0.4 0 0.4 0.4 18 4 17 305 21 0 21 0 -9.4 0 -8.8 -9.6 04/18/2005 13:50:00 10 1.3 12.6 6.8 10 1.3 12.6 7.2 0.4 0 0.4 0.4 16 5 17 305 21 0 21 0 -9.3 0.1 -8.8 -9.6 04/18/2005 14:00:00 9.1 1 11.5 6.8 9.2 0.9 11.1 6.8 0.4 0 0.4 0.4 16 5 16 305 22 0 21 0 -9 0 -8.6 -9.2 04/18/2005 14:10:00 9.8 1 12.2 6.8 9.8 1 12.6 6.8 0.4 0 0.4 0.4 18 5 12 305 22 0 22 0 -9 0 -8.6 -9.2 04/18/2005 14:20:00 10 0.8 11.8 7.6 10 0.8 11.8 8 0.4 0 0.4 0.4 18 5 16 305 22 0 22 0 -9 0 -8.6 -9.2 04/18/2005 14:30:00 10.9 1 13 8.8 10.8 1.1 13.3 8.4 0.4 0 0.4 0.4 15 5 17 305 22 0 22 0 -9 0 -8.6 -9.2 04/18/2005 14:40:00 11.3 1 13.7 9.1 11.3 1 13.3 8.8 0.4 0 0.4 0.4 19 5 21 305 21 0 21 0 -9 0 -8.6 -9.2 04/18/2005 14:50:00 10.4 0.8 12.6 8.4 10.3 0.9 12.6 7.2 0.4 0 0.4 0.4 20 6 26 305 22 0 22 0 -8.9 0 -8.6 -9 04/18/2005 15:00:00 10.6 0.9 13 8.4 10.6 1 13.3 8 0.4 0 0.4 0.4 18 5 10 305 22 0 22 0 -8.8 0 -8.4 -9 04/18/2005 15:10:00 11.3 1 13.3 8.8 11.2 0.9 13.3 8.8 0.4 0 0.4 0.4 20 5 8 305 22 0 22 0 -8.7 0 -8.4 -9 04/18/2005 15:20:00 11.2 1.1 13.7 8.4 11 1.1 13.7 8.4 0.4 0 0.4 0.4 19 5 15 305 22 0 22 0 -8.7 0 -8.4 -8.8 04/18/2005 15:30:00 10.7 1.3 13.7 7.6 10.5 1.3 14.5 7.6 0.4 0 0.4 0.4 15 6 11 305 22 0 22 0 -8.7 0 -8.4 -8.8 04/18/2005 15:40:00 9.9 1.1 12.6 7.2 9.8 1.1 13 7.2 0.4 0 0.4 0.4 17 6 24 305 22 0 22 0 -8.6 0.1 -8.2 -8.8 04/18/2005 15:50:00 9.7 1.2 13 7.2 9.7 1.2 13 6.8 0.4 0 0.4 0.4 16 6 13 305 22 0 22 0 -8.4 0 -8.2 -8.6 04/18/2005 16:00:00 11.6 1.1 13.7 8.8 11.6 1.1 14.1 8.4 0.4 0 0.4 0.4 18 6 16 305 22 0 22 0 -8.6 0.1 -8.2 -8.8 04/18/2005 16:10:00 11.6 0.8 14.1 8.8 11.5 0.9 13.7 9.1 0.4 0 0.4 0.4 22 4 17 305 22 0 22 0 -8.5 0.1 -8.2 -8.6 04/18/2005 16:20:00 10.7 0.9 12.6 8 10.6 0.9 12.6 8 0.4 0 0.4 0.4 17 6 13 305 22 0 22 0 -8.4 0 -7.9 -8.6 04/18/2005 16:30:00 10.7 1.1 13 7.6 10.6 1.1 13.3 7.6 0.4 0 0.4 0.4 17 6 11 305 22 0 22 0 -8.4 0 -7.9 -8.6 04/18/2005 16:40:00 10.4 1.2 13.7 7.2 10.2 1.2 13 6.8 0.4 0 0.4 0.4 21 5 17 305 22 0 22 0 -8.4 0 -7.9 -8.6 04/18/2005 16:50:00 10.6 1.1 13 8 10.6 1.1 13.3 8 0.4 0 0.4 0.4 17 5 14 305 22 0 22 0 -8.3 0 -7.9 -8.4 04/18/2005 17:00:00 10.2 1.1 13.3 7.2 10.3 1.2 13.3 7.2 0.4 0 0.4 0.4 12 6 14 305 22 0 22 0 -8.3 0 -8.2 -8.4 04/18/2005 17:10:00 10.2 1 12.6 7.6 10.2 1 13 8 0.4 0 0.4 0.4 13 5 8 305 21 0 21 0 -8.2 0 -7.9 -8.4 04/18/2005 17:20:00 10.5 1 13 7.6 10.5 1 13 8 0.4 0 0.4 0.4 12 5 8 305 21 0 21 0 -8.2 0 -7.9 -8.4 04/18/2005 17:30:00 10.3 1.1 13 7.2 10.4 1.1 13 7.6 0.4 0 0.4 0.4 15 6 0 305 21 0 21 0 -8.2 0 -7.7 -8.4 04/18/2005 17:40:00 10.3 0.9 12.2 7.6 10.2 1 12.2 7.6 0.4 0 0.4 0.4 14 5 9 305 21 0 21 0 -8.2 0 -7.7 -8.2 04/18/2005 17:50:00 10.6 1 12.6 8.4 10.7 1.1 13 7.6 0.4 0 0.4 0.4 15 5 14 305 21 0 21 0 -8.2 0 -7.7 -8.4 04/18/2005 18:00:00 10.7 1.1 13 8 10.7 1.2 13.3 8 0.4 0 0.4 0.4 12 5 6 305 21 0 21 0 -8.2 0 -7.7 -8.2 04/18/2005 18:10:00 10.6 1.1 13 7.2 10.5 1.1 12.6 7.6 0.4 0 0.4 0.4 16 6 4 305 21 0 21 0 -8.2 0 -7.9 -8.4 04/18/2005 18:20:00 10.7 0.9 12.6 8 10.6 0.9 13 8.4 0.4 0 0.4 0.4 19 5 18 305 20 0 20 0 -8.2 0 -7.9 -8.4 04/18/2005 18:30:00 10.3 1.2 12.6 7.2 10.3 1.3 13 7.2 0.4 0 0.4 0.4 14 6 10 305 20 0 20 0 -8.2 0 -7.7 -8.4 04/18/2005 18:40:00 10.5 1 13 7.6 10.5 1 13.3 7.6 0.4 0 0.4 0.4 11 5 8 305 20 0 19 0 -8.2 0 -7.7 -8.4 04/18/2005 18:50:00 10.6 1.3 13.7 7.6 10.5 1.3 13.7 8 0.4 0 0.4 0.4 12 5 12 305 19 0 19 0 -8.2 0 -7.9 -8.4 04/18/2005 19:00:00 10.7 1 13 8 10.7 1 13 8 0.4 0 0.4 0.4 17 5 18 305 19 0 19 0 -8.2 0 -7.9 -8.4 04/18/2005 19:10:00 10.4 1.1 12.6 7.6 10.4 1.2 13 7.6 0.4 0 0.4 0.4 17 5 18 305 19 0 19 0 -8.2 0 -7.9 -8.4 04/18/2005 19:20:00 10.3 1.3 13.3 7.2 10.3 1.3 13.3 7.2 0.4 0 0.4 0.4 15 5 19 305 19 0 19 0 -8.2 0 -7.9 -8.4 04/18/2005 19:30:00 10.5 1.1 13.3 8 10.4 1.1 13 8 0.4 0 0.4 0.4 19 4 15 305 18 0 18 0 -8.3 0 -7.9 -8.4 04/18/2005 19:40:00 10.3 1.2 12.6 6.8 10.1 1.2 13 7.2 0.4 0 0.4 0.4 19 6 17 305 18 0 18 0 -8.4 0 -8.2 -8.4 04/18/2005 19:50:00 10.8 0.9 13 7.6 10.6 0.9 13.3 8.4 0.4 0 0.4 0.4 20 5 17 305 18 0 18 0 -8.4 0 -8.2 -8.4 04/18/2005 20:00:00 10.6 1 12.6 8 10.4 1 13 8 0.4 0 0.4 0.4 21 5 16 305 18 0 18 0 -8.4 0 -8.2 -8.6 04/18/2005 20:10:00 10.6 1 13 8 10.6 1 12.6 8 0.4 0 0.4 0.4 20 5 23 305 18 0 18 0 -8.4 0 -8.2 -8.6 04/18/2005 20:20:00 10.5 0.9 12.6 8 10.3 1 12.6 7.6 0.4 0 0.4 0.4 20 5 25 305 17 0 17 0 -8.5 0 -8.2 -8.8 04/18/2005 20:30:00 10.7 1 12.6 7.6 10.6 1 12.6 8 0.4 0 0.4 0.4 20 4 22 305 17 0 17 0 -8.6 0 -8.4 -8.8 04/18/2005 20:40:00 10.3 0.9 12.6 8 10.2 0.9 12.6 8 0.4 0 0.4 0.4 21 5 24 305 16 0 16 0 -8.7 0 -8.4 -8.8 04/18/2005 20:50:00 10.7 0.9 12.6 8.4 10.5 1 12.6 8 0.4 0 0.4 0.4 20 4 19 305 16 0 16 0 -8.7 0 -8.4 -9 04/18/2005 21:00:00 11.1 0.7 12.6 9.5 10.9 0.8 12.6 9.1 0.4 0 0.4 0.4 19 4 16 305 16 0 16 0 -8.9 0.1 -8.6 -9.2 04/18/2005 21:10:00 10.7 0.8 13 8.4 10.4 0.9 13 8.4 0.4 0 0.4 0.4 20 4 25 305 15 0 15 0 -9 0 -8.8 -9.2 04/18/2005 21:20:00 10 1 12.2 7.2 9.7 1 12.2 7.2 0.4 0 0.4 0.4 20 5 14 305 15 0 15 0 -9 0 -8.8 -9.2 04/18/2005 21:30:00 10.9 0.7 12.6 8.8 10.6 0.8 12.2 8.4 0.4 0 0.4 0.4 18 4 17 305 14 0 14 0 -9.1 0.1 -8.8 -9.2 04/18/2005 21:40:00 10.6 0.9 13 8 10.4 0.8 12.6 8 0.4 0 0.4 0.4 18 4 15 305 14 0 14 0 -9.1 0 -8.8 -9.2 04/18/2005 21:50:00 10.5 0.7 12.6 9.1 10.4 0.8 12.2 8 0.4 0 0.4 0.4 18 4 22 305 14 0 14 0 -9.1 0.1 -8.8 -9.2 04/18/2005 22:00:00 10.6 0.8 12.6 8.4 10.4 0.8 12.6 8.4 0.4 0 0.4 0.4 20 4 17 305 14 0 14 0 -9.3 0 -9 -9.4 04/18/2005 22:10:00 10.3 0.8 12.2 8 10 0.8 12.2 7.2 0.4 0 0.4 0.4 20 4 24 305 14 0 14 0 -9.3 0 -9 -9.4 04/18/2005 22:20:00 10.4 0.8 12.2 8.4 10.2 0.8 12.2 8.4 0.4 0 0.4 0.4 18 4 22 305 13 0 13 0 -9.3 0 -9 -9.4 04/18/2005 22:30:00 9.8 1 12.2 7.6 9.7 1 11.8 7.2 0.4 0 0.4 0.4 23 5 25 305 13 0 13 0 -9.3 0 -9 -9.4 04/18/2005 22:40:00 9.5 0.7 11.5 8 9.3 0.7 11.5 7.6 0.4 0 0.4 0.4 30 4 27 305 13 0 13 0 -9.5 0 -9.2 -9.6 04/18/2005 22:50:00 9.5 0.8 11.5 7.2 9.3 0.7 11.5 7.6 0.4 0 0.4 0.4 29 5 28 305 13 0 13 0 -9.4 0 -9.2 -9.6 04/18/2005 23:00:00 9.5 0.7 11.5 8 9.3 0.7 11.8 8 0.4 0 0.4 0.4 33 4 27 305 13 0 13 0 -9.5 0 -9.2 -9.6 04/18/2005 23:10:00 10.7 1 13 8.4 10.4 1 13 8.4 0.4 0 0.4 0.4 33 4 32 305 13 0 13 0 -9.5 0 -9.2 -9.6 04/18/2005 23:20:00 11.6 0.8 13.3 9.5 11.3 0.9 13.3 8.8 0.4 0 0.4 0.4 33 4 35 305 13 0 13 0 -9.5 0 -9.2 -9.6 04/18/2005 23:30:00 11.8 0.9 13.7 9.5 11.4 0.9 13.3 9.1 0.4 0 0.4 0.4 29 4 28 305 13 0 13 0 -9.4 0 -9.2 -9.6 04/18/2005 23:40:00 11.7 1.1 14.1 9.1 11.4 1.1 14.1 8.8 0.4 0 0.4 0.4 29 4 27 305 13 0 13 0 -9.4 0 -9.2 -9.6 04/18/2005 23:50:00 11.2 1.1 14.1 8.8 11 1.1 14.1 8.4 0.4 0 0.4 0.4 30 5 27 305 13 0 13 0 -9.5 0 -9.2 -9.6 04/19/2005 00:00:00 11.9 1.2 14.9 8.4 11.6 1.2 14.5 8.8 0.4 0 0.4 0.4 30 4 27 305 13 0 13 0 -9.5 0 -9.2 -9.6 04/19/2005 00:10:00 11.9 1 14.5 9.1 11.6 1 14.1 9.5 0.4 0 0.4 0.4 30 5 31 305 13 0 13 0 -9.6 0 -9.2 -9.8 04/19/2005 00:20:00 12.1 0.8 14.1 9.9 11.9 0.9 14.1 9.5 0.4 0 0.4 0.4 31 5 28 305 12 0 12 0 -9.6 0 -9.2 -9.8 04/19/2005 00:30:00 12.6 0.9 14.9 9.9 12.3 1 14.9 9.5 0.4 0 0.4 0.4 33 5 37 305 12 0 13 0 -9.6 0 -9.2 -9.8 04/19/2005 00:40:00 12.3 1 14.5 9.1 12 1.1 14.5 8.8 0.4 0 0.4 0.4 33 5 34 305 12 0 12 0 -9.7 0.1 -9.2 -9.8 04/19/2005 00:50:00 13 0.9 15.3 9.9 12.6 0.9 14.9 10.7 0.4 0 0.4 0.4 34 4 32 305 12 0 12 0 -9.8 0 -9.4 -10 04/19/2005 01:00:00 12.9 1 14.9 10.3 12.5 1 14.9 9.9 0.4 0 0.4 0.4 33 4 30 305 12 0 12 0 -9.8 0 -9.6 -10 04/19/2005 01:10:00 11.3 1.1 14.5 8.4 11 1.1 13.7 8 0.4 0 0.4 0.4 35 5 32 305 12 0 12 0 -10.1 0.1 -9.6 -10.4 04/19/2005 01:20:00 10.4 0.8 12.6 8 10.2 0.9 12.2 8.4 0.4 0 0.4 0.4 38 5 37 305 12 0 12 0 -10.3 0.1 -9.8 -10.4 04/19/2005 01:30:00 11.9 0.8 13.3 9.1 11.8 0.8 13.7 9.1 0.4 0 0.4 0.4 39 4 42 305 12 0 12 0 -10.3 0 -10 -10.4 04/19/2005 01:40:00 10.9 0.8 13 8.8 10.6 0.9 12.6 8.4 0.4 0 0.4 0.4 38 5 37 305 12 0 12 0 -10.3 0 -10 -10.4 04/19/2005 01:50:00 10.1 0.8 12.2 7.2 9.8 0.8 12.2 7.2 0.4 0 0.4 0.4 34 4 36 305 12 0 12 0 -10.4 0 -10 -10.7 04/19/2005 02:00:00 10.6 0.9 12.6 8.8 10.3 0.9 12.6 8 0.4 0 0.4 0.4 34 5 34 305 11 0 11 0 -10.4 0 -10.2 -10.7 04/19/2005 02:10:00 10.2 0.7 12.6 8.4 9.9 0.7 11.8 8 0.4 0 0.4 0.4 35 5 26 305 11 0 11 0 -10.4 0 -10.2 -10.7 04/19/2005 02:20:00 10.8 0.8 12.6 8.4 10.5 0.9 12.6 8 0.4 0 0.4 0.4 34 5 34 305 11 0 11 0 -10.4 0 -10 -10.9 04/19/2005 02:30:00 11.4 0.9 13.3 8.8 11.1 1 13.3 8 0.4 0 0.4 0.4 37 3 36 305 11 0 11 0 -10.5 0 -10.2 -10.9 04/19/2005 02:40:00 10.4 0.8 13 8.4 10.2 0.9 12.6 8 0.4 0 0.4 0.4 36 4 35 305 11 0 11 0 -10.7 0.1 -10.2 -10.9 04/19/2005 02:50:00 10.7 1.3 13.3 8 10.4 1.3 12.6 7.2 0.4 0 0.4 0.4 39 5 39 305 11 0 11 0 -10.7 0.1 -10.4 -10.9 04/19/2005 03:00:00 8.9 1 11.8 6.8 8.6 1 11.5 6.8 0.4 0 0.4 0.4 49 6 40 305 10 0 11 0 -11.1 0.2 -10.7 -11.5 04/19/2005 03:10:00 9.4 0.6 11.1 7.6 9.1 0.7 11.1 6.8 0.4 0 0.4 0.4 51 4 50 305 10 0 10 0 -11.4 0 -11.3 -11.5 04/19/2005 03:20:00 9.5 0.9 11.5 6.8 9.2 0.9 11.5 6.5 0.4 0 0.4 0.4 49 5 55 305 10 0 10 0 -11.5 0 -11.3 -11.7 04/19/2005 03:30:00 9.5 0.8 11.5 6.8 9.2 0.8 11.1 6.8 0.4 0 0.4 0.4 45 5 41 305 10 0 10 0 -11.5 0 -11.3 -11.7 04/19/2005 03:40:00 8.6 0.6 10.3 7.2 8.4 0.6 9.9 6.5 0.4 0 0.4 0.4 49 4 41 305 9 0 9 0 -11.6 0 -11.3 -11.7 04/19/2005 03:50:00 7.8 0.6 9.9 6.1 7.6 0.6 9.5 6.5 0.4 0 0.4 0.4 45 5 43 305 9 0 9 0 -11.8 0.1 -11.5 -12.1 04/19/2005 04:00:00 9 1 11.5 6.5 8.6 1 11.1 6.1 0.4 0 0.4 0.4 44 6 38 305 9 0 9 0 -11.6 0 -11.3 -11.9 04/19/2005 04:10:00 8.3 0.6 9.9 6.8 8 0.5 9.5 6.8 0.4 0 0.4 0.4 45 4 41 305 9 0 9 0 -11.8 0 -11.5 -12.1 04/19/2005 04:20:00 8.1 0.6 9.9 6.5 7.9 0.6 9.5 6.5 0.4 0 0.4 0.4 39 5 36 305 9 0 9 0 -11.8 0 -11.5 -12.1 04/19/2005 04:30:00 7.5 0.8 10.7 6.1 7.2 0.8 10.3 5.7 0.4 0 0.4 0.4 47 5 37 305 9 0 9 0 -11.9 0.1 -11.7 -12.1 04/19/2005 04:40:00 7.5 0.6 9.5 6.1 7.1 0.7 9.1 5.7 0.4 0 0.4 0.4 47 5 45 305 9 0 9 0 -12 0 -11.7 -12.1 04/19/2005 04:50:00 8.1 0.5 9.1 6.8 7.8 0.6 9.1 6.5 0.4 0 0.4 0.4 45 3 40 305 9 0 9 0 -12 0 -11.9 -12.1 04/19/2005 05:00:00 7.5 0.7 9.1 5.7 7.3 0.7 8.8 5.3 0.4 0 0.4 0.4 51 6 48 305 9 0 9 0 -12 0 -11.7 -12.3 04/19/2005 05:10:00 7.2 0.6 8.8 5.7 7.1 0.7 8.8 5.3 0.4 0 0.4 0.4 54 7 59 305 9 0 9 0 -12.1 0 -11.9 -12.5 04/19/2005 05:20:00 6.9 0.4 8 5.7 6.8 0.4 8 5.3 0.4 0 0.4 0.4 47 4 41 305 9 0 9 0 -12.2 0 -12.1 -12.5 04/19/2005 05:30:00 7 0.4 8.4 6.1 6.8 0.4 8 5.7 0.4 0 0.4 0.4 45 4 46 305 9 0 8 0 -12.4 0.1 -12.1 -12.5 04/19/2005 05:40:00 7.5 0.5 9.1 6.1 7.3 0.5 8.8 6.1 0.4 0 0.4 0.4 45 4 48 305 8 0 8 0 -12.4 0.1 -12.3 -12.5 04/19/2005 05:50:00 7.7 0.5 9.1 6.8 7.4 0.5 9.1 6.5 0.4 0 0.4 0.4 48 5 40 305 8 0 8 0 -12.5 0 -12.3 -12.5 04/19/2005 06:00:00 7.7 0.4 9.1 6.8 7.4 0.4 8.8 6.5 0.4 0 0.4 0.4 45 4 46 305 8 0 8 0 -12.5 0 -12.3 -12.5 04/19/2005 06:10:00 8.4 0.6 9.9 6.8 8.1 0.6 9.9 6.5 0.4 0 0.4 0.4 44 4 48 305 8 0 8 0 -12.4 0.1 -12.1 -12.5 04/19/2005 06:20:00 8 0.5 9.1 6.8 7.7 0.5 8.8 6.5 0.4 0 0.4 0.4 46 4 44 305 8 0 8 0 -12.5 0 -12.1 -12.5 04/19/2005 06:30:00 7.8 0.5 9.1 6.8 7.6 0.5 8.8 6.1 0.4 0 0.4 0.4 47 4 43 305 8 0 8 0 -12.5 0 -12.3 -12.7 04/19/2005 06:40:00 7.9 0.5 9.1 6.1 7.6 0.5 8.8 6.1 0.4 0 0.4 0.4 47 4 46 305 8 0 8 0 -12.5 0 -12.1 -12.5 04/19/2005 06:50:00 7.7 0.5 8.8 6.5 7.5 0.5 9.1 6.1 0.4 0 0.4 0.4 49 3 51 305 8 0 8 0 -12.5 0 -12.1 -12.7 04/19/2005 07:00:00 8.2 0.5 9.9 6.8 8 0.5 9.5 6.5 0.4 0 0.4 0.4 47 4 50 305 8 0 8 0 -12.5 0 -12.1 -12.5 04/19/2005 07:10:00 7.9 0.5 9.1 6.8 7.6 0.5 9.1 6.5 0.4 0 0.4 0.4 41 5 43 305 8 0 8 0 -12.4 0.1 -12.1 -12.5 04/19/2005 07:20:00 8.9 0.8 10.7 7.2 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 39 4 38 305 9 0 9 0 -12.2 0.1 -11.9 -12.5 04/19/2005 07:30:00 9 0.5 10.3 7.6 8.8 0.5 10.3 7.6 0.4 0 0.4 0.4 43 4 36 305 9 0 9 0 -12.3 0 -12.1 -12.5 04/19/2005 07:40:00 8.9 0.5 10.3 7.6 8.7 0.5 10.3 7.6 0.4 0 0.4 0.4 46 3 48 305 9 0 9 0 -12.4 0.1 -12.1 -12.5 04/19/2005 07:50:00 8.3 0.5 9.9 6.8 8.1 0.5 9.9 6.8 0.4 0 0.4 0.4 46 3 44 305 9 0 9 0 -12.5 0.1 -12.1 -12.5 04/19/2005 08:00:00 8.5 0.5 9.9 7.2 8.2 0.5 9.5 6.8 0.4 0 0.4 0.4 46 4 46 305 9 0 9 0 -12.3 0 -12.1 -12.5 04/19/2005 08:10:00 8.3 0.5 9.9 7.2 8.1 0.5 9.1 6.8 0.4 0 0.4 0.4 46 4 52 305 9 0 9 0 -12.3 0 -12.1 -12.5 04/19/2005 08:20:00 8.2 0.5 9.5 6.8 8 0.6 9.9 6.1 0.4 0 0.4 0.4 48 4 39 305 10 0 9 0 -12.2 0 -11.9 -12.5 04/19/2005 08:30:00 8.5 0.5 9.9 7.2 8.3 0.5 9.9 6.8 0.4 0 0.4 0.4 46 3 42 305 10 0 10 0 -12.2 0 -11.9 -12.3 04/19/2005 08:40:00 9.5 0.6 11.1 8 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 44 4 44 305 10 0 10 0 -12.1 0 -11.7 -12.3 04/19/2005 08:50:00 9 0.5 10.3 7.6 8.9 0.6 10.3 7.2 0.4 0 0.4 0.4 44 3 49 305 10 0 10 0 -12.1 0 -11.7 -12.3 04/19/2005 09:00:00 8.7 0.6 9.9 7.2 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 45 3 41 305 10 0 10 0 -12 0 -11.7 -12.3 04/19/2005 09:10:00 8.7 0.5 9.9 7.6 8.6 0.5 9.9 7.2 0.4 0 0.4 0.4 45 3 44 305 10 0 10 0 -12.1 0 -11.9 -12.3 04/19/2005 09:20:00 8.1 0.6 9.5 6.8 7.9 0.6 9.1 6.5 0.4 0 0.4 0.4 44 4 37 305 10 0 10 0 -12 0 -12.1 -12.3 04/19/2005 09:30:00 9.1 0.6 10.7 7.2 8.9 0.6 10.3 7.2 0.4 0 0.4 0.4 43 4 40 305 11 0 11 0 -12 0 -11.7 -12.1 04/19/2005 09:40:00 9 0.5 10.7 8 8.8 0.6 10.7 7.2 0.4 0 0.4 0.4 45 4 49 305 11 0 11 0 -11.9 0 -11.7 -12.1 04/19/2005 09:50:00 9.1 0.7 11.1 7.2 9 0.7 11.1 7.2 0.4 0 0.4 0.4 45 4 49 305 11 0 11 0 -11.9 0 -11.7 -12.1 04/19/2005 10:00:00 9.4 0.6 10.7 7.6 9.3 0.7 10.7 7.6 0.4 0 0.4 0.4 46 4 46 305 11 0 11 0 -11.8 0 -11.5 -11.9 04/19/2005 10:10:00 8.9 0.6 10.3 7.6 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 44 3 48 305 11 0 11 0 -11.7 0 -11.3 -11.9 04/19/2005 10:20:00 8.5 0.6 10.3 7.2 8.3 0.6 9.9 6.8 0.4 0 0.4 0.4 43 4 39 305 12 0 12 0 -11.5 0 -10.9 -11.7 04/19/2005 10:30:00 8.9 0.7 10.7 7.2 8.8 0.7 11.1 6.8 0.4 0 0.4 0.4 44 5 48 305 12 0 12 0 -11.4 0 -10.9 -11.5 04/19/2005 10:40:00 8.9 0.7 10.7 7.2 8.7 0.7 10.7 6.8 0.4 0 0.4 0.4 42 4 43 305 12 0 12 0 -11.3 0.1 -10.9 -11.5 04/19/2005 10:50:00 9.5 0.8 11.1 6.8 9.4 0.8 10.7 6.8 0.4 0 0.4 0.4 41 5 40 305 12 0 12 0 -11.1 0 -10.7 -11.3 04/19/2005 11:00:00 9.5 0.6 11.1 7.6 9.3 0.7 11.1 7.2 0.4 0 0.4 0.4 44 4 45 305 13 0 13 0 -11 0 -10.7 -11.3 04/19/2005 11:10:00 9.7 0.7 11.5 8 9.5 0.8 11.5 7.2 0.4 0 0.4 0.4 36 6 35 305 13 0 12 0 -10.9 0.1 -10.4 -11.3 04/19/2005 11:20:00 9.9 0.8 11.5 7.2 9.7 0.8 11.8 6.5 0.4 0 0.4 0.4 36 6 30 305 13 0 13 0 -10.9 0.1 -10.4 -11.3 04/19/2005 11:30:00 9.7 0.6 11.1 7.6 9.6 0.7 11.5 7.2 0.4 0 0.4 0.4 41 4 45 305 13 0 12 0 -11.2 0 -10.9 -11.3 04/19/2005 11:40:00 9.4 0.7 11.1 7.2 9.3 0.7 10.7 6.5 0.4 0 0.4 0.4 45 4 45 305 13 0 13 0 -11.1 0 -10.7 -11.3 04/19/2005 11:50:00 9 0.7 10.7 7.2 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 44 4 46 305 13 0 13 0 -11 0 -10.4 -11.3 04/19/2005 12:00:00 9.2 0.8 10.7 7.2 9.1 0.9 10.7 6.5 0.4 0 0.4 0.4 43 4 43 305 13 0 13 0 -11.1 0 -10.7 -11.3 04/19/2005 12:10:00 8.7 0.6 9.9 7.2 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 47 4 47 305 13 0 13 0 -11 0 -10.4 -11.1 04/19/2005 12:20:00 8.9 0.6 10.3 7.2 8.8 0.6 10.3 6.8 0.4 0 0.4 0.4 44 5 47 305 13 0 13 0 -10.9 0 -10.4 -10.9 04/19/2005 12:30:00 8.8 0.6 10.3 7.2 8.6 0.6 10.3 7.2 0.4 0 0.4 0.4 46 5 40 305 13 0 13 0 -10.8 0.1 -10.4 -10.9 04/19/2005 12:40:00 8.8 0.7 10.7 7.2 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 46 5 49 305 13 0 13 0 -10.8 0 -10.4 -10.9 04/19/2005 12:50:00 8.8 0.7 10.3 7.2 8.7 0.7 9.9 6.8 0.4 0 0.4 0.4 46 3 46 305 12 0 12 0 -10.8 0.1 -10.4 -10.9 04/19/2005 13:00:00 8.4 0.6 9.9 6.8 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 46 4 43 305 12 0 12 0 -10.6 0 -10.2 -10.9 04/19/2005 13:10:00 8.3 0.7 9.5 6.5 8.3 0.8 9.9 6.5 0.4 0 0.4 0.4 44 4 44 305 12 0 12 0 -10.4 0 -10 -10.7 04/19/2005 13:20:00 8.7 0.6 10.3 7.2 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 42 5 46 305 12 0 12 0 -10.3 0 -10 -10.4 04/19/2005 13:30:00 8.4 0.6 9.5 6.8 8.4 0.6 9.5 6.8 0.4 0 0.4 0.4 43 3 45 305 12 0 12 0 -10.2 0 -10 -10.4 04/19/2005 13:40:00 7.9 0.8 9.9 5.3 7.9 0.8 9.9 6.1 0.4 0 0.4 0.4 39 6 36 305 12 0 12 0 -10.1 0.1 -9.8 -10.4 04/19/2005 13:50:00 8.1 0.8 9.5 6.1 8 0.8 9.5 5.7 0.4 0 0.4 0.4 44 5 48 305 11 0 12 0 -10.1 0 -9.8 -10.4 04/19/2005 14:00:00 7.9 0.5 9.1 6.1 7.9 0.5 9.1 6.5 0.4 0 0.4 0.4 39 5 43 305 11 0 11 0 -10 0 -9.8 -10.2 04/19/2005 14:10:00 7.6 0.7 9.1 5.7 7.5 0.7 9.1 5.3 0.4 0 0.4 0.4 35 6 38 305 11 0 11 0 -9.9 0.1 -9.6 -10 04/19/2005 14:20:00 7.7 0.7 9.5 6.1 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 32 6 27 305 11 0 11 0 -9.8 0 -9.6 -10 04/19/2005 14:30:00 7.5 0.5 9.1 5.7 7.4 0.6 9.1 5.7 0.4 0 0.4 0.4 32 6 27 305 11 0 11 0 -9.7 0 -9.4 -9.8 04/19/2005 14:40:00 7.7 0.5 8.8 6.5 7.6 0.6 8.8 5.7 0.4 0 0.4 0.4 33 6 22 305 11 0 11 0 -9.6 0.1 -9.2 -9.8 04/19/2005 14:50:00 7.4 0.6 8.8 5.7 7.4 0.5 8.8 5.3 0.4 0 0.4 0.4 32 5 31 305 11 0 11 0 -9.6 0 -9.2 -9.6 04/19/2005 15:00:00 7.4 0.7 9.1 5.3 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 37 6 28 305 11 0 11 0 -9.6 0 -9.2 -9.6 04/19/2005 15:10:00 7.7 0.6 9.1 6.1 7.7 0.7 9.1 5.7 0.4 0 0.4 0.4 41 5 42 305 11 0 11 0 -9.6 0 -9.4 -9.8 04/19/2005 15:20:00 7.7 0.5 9.1 6.1 7.6 0.6 8.8 6.1 0.4 0 0.4 0.4 37 5 40 305 11 0 11 0 -9.4 0 -9 -9.6 04/19/2005 15:30:00 8 0.5 9.5 6.8 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 35 5 41 305 10 0 11 0 -9.4 0 -9 -9.6 04/19/2005 15:40:00 7.9 0.8 9.5 5.7 7.9 0.8 9.9 6.1 0.4 0 0.4 0.4 34 5 41 305 10 0 10 0 -9.3 0 -8.8 -9.6 04/19/2005 15:50:00 7.9 0.6 9.1 6.1 7.9 0.6 9.1 6.5 0.4 0 0.4 0.4 37 5 43 305 10 0 10 0 -9.3 0 -9 -9.4 04/19/2005 16:00:00 7.6 0.7 8.8 5.7 7.6 0.8 9.1 5.7 0.4 0 0.4 0.4 33 7 37 305 9 0 9 0 -9.3 0.1 -8.8 -9.4 04/19/2005 16:10:00 7.8 0.7 9.5 6.1 7.8 0.7 9.5 5.7 0.4 0 0.4 0.4 34 6 35 305 9 0 9 0 -9.2 0 -8.8 -9.4 04/19/2005 16:20:00 7.8 0.6 9.1 6.1 7.9 0.7 9.1 6.1 0.4 0 0.4 0.4 35 5 38 305 9 0 9 0 -9.3 0 -8.8 -9.4 04/19/2005 16:30:00 8.2 0.5 9.5 6.5 8.2 0.6 9.1 5.7 0.4 0 0.4 0.4 37 4 38 305 8 0 9 0 -9.4 0 -9 -9.6 04/19/2005 16:40:00 8 0.6 9.5 6.5 8 0.7 9.5 6.1 0.4 0 0.4 0.4 36 5 35 305 8 0 8 0 -9.3 0 -9 -9.4 04/19/2005 16:50:00 8.1 0.6 9.5 6.5 8.1 0.6 9.1 6.1 0.4 0 0.4 0.4 36 4 37 305 8 0 8 0 -9.3 0 -9 -9.4 04/19/2005 17:00:00 7.8 0.6 9.1 6.1 7.8 0.7 9.5 5.7 0.4 0 0.4 0.4 35 4 35 305 8 0 8 0 -9.3 0 -8.8 -9.4 04/19/2005 17:10:00 7.8 0.6 8.8 6.1 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 33 4 33 305 7 0 7 0 -9.3 0 -8.8 -9.4 04/19/2005 17:20:00 7.4 0.5 8.8 6.1 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 32 5 34 305 7 0 7 0 -9.2 0 -8.8 -9.2 04/19/2005 17:30:00 7.4 0.5 8.8 5.7 7.4 0.5 8.8 5.7 0.4 0 0.4 0.4 37 5 39 305 7 0 7 0 -9.1 0 -8.8 -9.2 04/19/2005 17:40:00 7.4 0.6 9.1 5.7 7.4 0.7 9.1 5.7 0.4 0 0.4 0.4 37 4 42 305 7 0 7 0 -9.1 0 -9 -9.2 04/19/2005 17:50:00 7 0.5 8.8 5.3 7 0.6 8.4 5.7 0.4 0 0.4 0.4 35 5 35 305 7 0 7 0 -9.1 0 -8.8 -9.2 04/19/2005 18:00:00 7.1 0.6 8.4 5.3 7.1 0.6 8.4 5.3 0.4 0 0.4 0.4 40 4 42 305 7 0 7 0 -9.1 0.1 -8.8 -9.2 04/19/2005 18:10:00 7 0.6 8.4 5.3 7 0.7 8.4 5.3 0.4 0 0.4 0.4 35 4 42 305 6 0 6 0 -9 0 -8.8 -9.2 04/19/2005 18:20:00 6.8 0.6 8 5.3 6.7 0.6 8 4.6 0.4 0 0.4 0.4 36 5 39 305 6 0 6 0 -9 0 -8.8 -9.2 04/19/2005 18:30:00 7 0.5 8.4 5.7 7 0.5 8.4 5.7 0.4 0 0.4 0.4 39 5 42 305 6 0 6 0 -9 0 -8.8 -9.2 04/19/2005 18:40:00 6.9 0.6 8.4 5.3 6.9 0.6 8.4 5.3 0.4 0 0.4 0.4 40 4 45 305 6 0 6 0 -9 0 -8.8 -9.2 04/19/2005 18:50:00 7.2 0.5 8 5.7 7.2 0.5 8.4 6.1 0.4 0 0.4 0.4 39 4 44 305 6 0 6 0 -9 0 -8.8 -9.2 04/19/2005 19:00:00 7.3 0.6 8.4 5.7 7.3 0.6 8.4 5.3 0.4 0 0.4 0.4 39 4 39 305 6 0 6 0 -9.1 0 -9 -9.2 04/19/2005 19:10:00 6.8 0.5 8.4 5.7 6.7 0.5 8.4 5.3 0.4 0 0.4 0.4 41 5 46 305 5 0 5 0 -9.3 0 -9 -9.4 04/19/2005 19:20:00 7.2 0.6 8.8 6.1 7.2 0.6 9.1 5.7 0.4 0 0.4 0.4 37 3 37 305 5 0 5 0 -9.3 0 -9.2 -9.4 04/19/2005 19:30:00 7.1 0.6 8.4 5.3 7.2 0.6 8.4 5.7 0.4 0 0.4 0.4 38 3 35 305 5 0 5 0 -9.3 0 -9.2 -9.6 04/19/2005 19:40:00 6.8 0.5 8.4 5.7 6.7 0.6 8 5.3 0.4 0 0.4 0.4 40 4 47 305 5 0 5 0 -9.3 0 -9.2 -9.4 04/19/2005 19:50:00 6.9 0.4 8 5.7 6.8 0.4 8 5.7 0.4 0 0.4 0.4 41 3 37 305 5 0 5 0 -9.6 0.2 -9.2 -10 04/19/2005 20:00:00 6.2 0.6 7.6 4.9 6.2 0.5 7.2 4.9 0.4 0 0.4 0.4 39 3 40 305 4 0 4 0 -9.8 0 -9.4 -10 04/19/2005 20:10:00 6.1 0.5 7.2 4.6 6 0.5 7.6 4.9 0.4 0 0.4 0.4 39 4 42 305 4 0 4 0 -9.8 0.1 -9.4 -10 04/19/2005 20:20:00 5.8 0.4 6.8 4.6 5.7 0.4 6.5 4.6 0.4 0 0.4 0.4 39 4 41 305 4 0 4 0 -10.1 0.1 -9.6 -10.4 04/19/2005 20:30:00 5.7 0.5 6.8 4.6 5.6 0.5 7.2 4.6 0.4 0 0.4 0.4 41 4 44 305 4 0 4 0 -10.2 0.1 -9.8 -10.4 04/19/2005 20:40:00 5.4 0.4 6.5 4.6 5.3 0.4 6.5 4.6 0.4 0 0.4 0.4 40 3 44 305 4 0 4 0 -10.1 0 -9.8 -10.2 04/19/2005 20:50:00 5.5 0.4 6.5 4.6 5.3 0.4 6.5 4.6 0.4 0 0.4 0.4 40 3 40 305 4 0 5 0 -10.2 0.1 -9.8 -10.4 04/19/2005 21:00:00 5.5 0.3 6.5 4.6 5.3 0.3 6.5 4.6 0.4 0 0.4 0.4 41 3 41 305 4 0 4 0 -10.4 0 -10.2 -10.4 04/19/2005 21:10:00 5.4 0.5 6.8 4.6 5.2 0.4 6.5 4.2 0.4 0 0.4 0.4 41 3 37 305 4 0 4 0 -10.4 0 -10.2 -10.9 04/19/2005 21:20:00 5.4 0.4 6.5 4.6 5.3 0.3 6.1 4.6 0.4 0 0.4 0.4 42 3 43 305 4 0 4 0 -10.8 0.1 -10.4 -10.9 04/19/2005 21:30:00 5.1 0.4 6.5 4.6 5 0.4 6.1 4.2 0.4 0 0.4 0.4 41 3 46 305 4 0 4 0 -10.9 0 -10.7 -11.1 04/19/2005 21:40:00 5.2 0.2 6.1 4.6 5 0.3 5.7 4.2 0.4 0 0.4 0.4 40 3 39 305 4 0 4 0 -11.2 0.1 -10.9 -11.5 04/19/2005 21:50:00 4.8 0.4 5.7 3.8 4.7 0.3 5.3 3.8 0.4 0 0.4 0.4 39 3 43 305 4 0 4 0 -11.2 0 -10.9 -11.3 04/19/2005 22:00:00 4.8 0.2 5.3 4.2 4.7 0.2 5.3 4.2 0.4 0 0.4 0.4 44 3 43 305 4 0 4 0 -11.4 0 -11.1 -11.5 04/19/2005 22:10:00 4.8 0.3 5.3 4.2 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 42 4 36 305 4 0 4 0 -11.3 0 -11.1 -11.5 04/19/2005 22:20:00 4.6 0.3 5.3 3.8 4.4 0.3 4.9 3.8 0.4 0 0.4 0.4 42 4 32 305 4 0 4 0 -11.4 0 -11.3 -11.5 04/19/2005 22:30:00 4.4 0.3 5.3 3.4 4.3 0.3 5.3 3.4 0.4 0 0.4 0.4 43 3 46 305 4 0 4 0 -11.4 0 -11.1 -11.5 04/19/2005 22:40:00 4.4 0.3 5.3 3.8 4.3 0.3 4.9 3.4 0.4 0 0.4 0.4 45 3 38 305 4 0 4 0 -11.3 0.1 -11.1 -11.5 04/19/2005 22:50:00 4.8 0.3 5.3 4.2 4.6 0.2 5.3 4.2 0.4 0 0.4 0.4 45 3 42 305 4 0 4 0 -11.4 0 -11.3 -11.7 04/19/2005 23:00:00 4.9 0.3 5.7 4.2 4.7 0.3 5.7 4.2 0.4 0 0.4 0.4 50 3 48 305 4 0 4 0 -11.5 0.1 -11.3 -11.7 04/19/2005 23:10:00 4.8 0.3 5.7 4.2 4.6 0.3 5.7 3.8 0.4 0 0.4 0.4 51 4 49 305 4 0 4 0 -11.4 0 -11.3 -11.7 04/19/2005 23:20:00 5.1 0.4 5.7 4.2 5 0.4 6.1 4.2 0.4 0 0.4 0.4 52 3 55 305 4 0 4 0 -11.6 0.1 -11.3 -11.9 04/19/2005 23:30:00 4.9 0.3 5.7 3.8 4.8 0.3 5.7 4.2 0.4 0 0.4 0.4 50 3 55 305 4 0 5 0 -11.2 0 -10.9 -11.5 04/19/2005 23:40:00 4.6 0.4 5.3 3.4 4.5 0.4 5.7 3.4 0.4 0 0.4 0.4 53 3 49 305 5 0 5 0 -11.2 0 -11.1 -11.5 04/19/2005 23:50:00 4.9 0.4 5.7 3.4 4.8 0.4 5.7 3.4 0.4 0 0.4 0.4 50 4 51 305 5 0 5 0 -11.1 0.1 -10.9 -11.3 04/20/2005 00:00:00 4.6 0.4 5.7 3.8 4.5 0.4 5.3 3.8 0.4 0 0.4 0.4 51 4 48 305 5 0 5 0 -11 0 -10.7 -11.3 04/20/2005 00:10:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3.4 0.4 0 0.4 0.4 53 4 55 305 5 0 5 0 -11.2 0 -10.9 -11.5 04/20/2005 00:20:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3.4 0.4 0 0.4 0.4 55 4 52 305 5 0 5 0 -11.2 0 -10.9 -11.3 04/20/2005 00:30:00 4.3 0.3 5.7 3.8 4.3 0.3 4.9 3.4 0.4 0 0.4 0.4 54 4 39 305 5 0 5 0 -11.2 0.1 -10.9 -11.3 04/20/2005 00:40:00 4.2 0.4 5.3 3.4 4.2 0.3 5.3 3.4 0.4 0 0.4 0.4 52 4 51 305 5 0 5 0 -11.2 0 -10.9 -11.3 04/20/2005 00:50:00 4.1 0.3 4.9 3.4 4.2 0.3 4.9 3.4 0.4 0 0.4 0.4 54 4 57 305 5 0 5 0 -11.2 0.1 -10.9 -11.5 04/20/2005 01:00:00 4 0.3 4.9 3 4 0.3 4.9 3.4 0.4 0 0.4 0.4 56 5 50 305 5 0 5 0 -11.2 0 -10.9 -11.3 04/20/2005 01:10:00 4 0.3 4.6 3 4 0.3 4.9 3.4 0.4 0 0.4 0.4 56 4 57 305 5 0 5 0 -11.1 0 -10.9 -11.3 04/20/2005 01:20:00 3.8 0.3 4.6 3 3.6 0.3 4.2 3 0.4 0 0.4 0.4 58 3 59 305 5 0 5 0 -11.5 0.3 -11.1 -12.1 04/20/2005 01:30:00 3.7 0.3 4.6 3 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 59 3 58 305 5 0 5 0 -11.8 0 -11.7 -12.1 04/20/2005 01:40:00 3.7 0.2 4.6 3 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 58 3 56 305 5 0 5 0 -11.5 0 -11.3 -11.7 04/20/2005 01:50:00 3.8 0.3 4.6 3 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 56 3 58 305 5 0 5 0 -12 0.3 -11.5 -12.5 04/20/2005 02:00:00 3.9 0.3 4.6 3 3.9 0.3 4.6 3.4 0.4 0 0.4 0.4 52 3 57 305 5 0 5 0 -11.9 0.1 -11.7 -12.1 04/20/2005 02:10:00 3.9 0.2 4.6 3.4 3.8 0.2 4.2 3 0.4 0 0.4 0.4 55 2 57 305 5 0 5 0 -11.6 0.1 -11.3 -12.1 04/20/2005 02:20:00 3.7 0.2 4.2 3 3.7 0.3 4.2 3 0.4 0 0.4 0.4 55 3 54 305 5 0 5 0 -11.4 0 -11.3 -11.5 04/20/2005 02:30:00 3.5 0.3 4.2 2.6 3.5 0.2 4.2 2.6 0.4 0 0.4 0.4 53 3 52 305 5 0 5 0 -11.3 0 -11.1 -11.5 04/20/2005 02:40:00 3.8 0.2 4.2 3 3.8 0.2 4.2 3.4 0.4 0 0.4 0.4 49 3 48 305 5 0 5 0 -11.5 0 -11.3 -11.9 04/20/2005 02:50:00 3.4 0.2 4.2 2.6 3.5 0.2 3.8 3 0.4 0 0.4 0.4 54 3 49 305 5 0 5 0 -11.3 0.1 -10.9 -11.7 04/20/2005 03:00:00 3.5 0.3 4.2 3 3.4 0.3 3.8 2.6 0.4 0 0.4 0.4 58 4 56 305 5 0 5 0 -11.1 0 -10.9 -11.3 04/20/2005 03:10:00 3.2 0.3 3.8 2.6 3.2 0.3 3.8 2.6 0.4 0 0.4 0.4 61 5 61 305 5 0 5 0 -11.4 0.1 -10.9 -11.7 04/20/2005 03:20:00 3.1 0.2 3.8 2.6 3.1 0.2 3.8 2.6 0.4 0 0.4 0.4 63 4 68 305 5 0 5 0 -11.6 0.1 -10.9 -11.9 04/20/2005 03:30:00 3.3 0.3 4.2 2.6 3.1 0.3 4.2 2.6 0.4 0 0.4 0.4 58 5 64 305 5 0 5 0 -11.3 0.1 -10.9 -11.5 04/20/2005 03:40:00 3.9 0.4 4.9 3 3.8 0.4 4.9 2.6 0.4 0 0.4 0.4 61 3 61 305 5 0 5 0 -11.3 0.1 -10.9 -11.7 04/20/2005 03:50:00 4.1 0.4 4.9 3.4 4.2 0.3 4.9 3.4 0.4 0 0.4 0.4 56 4 60 305 5 0 6 0 -11.1 0.2 -10.7 -11.5 04/20/2005 04:00:00 3.9 0.4 4.9 3 3.9 0.4 4.6 3 0.4 0 0.4 0.4 55 4 55 305 5 0 5 0 -11.1 0 -10.9 -11.3 04/20/2005 04:10:00 3.5 0.4 4.2 2.3 3.6 0.4 4.6 2.3 0.4 0 0.4 0.4 54 6 47 305 6 0 6 0 -10.9 0 -10.4 -11.3 04/20/2005 04:20:00 3.1 0.4 4.2 2.3 3.2 0.3 4.2 2.3 0.4 0 0.4 0.4 51 6 61 305 6 0 6 0 -10.8 0.1 -10.4 -11.1 04/20/2005 04:30:00 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 0.4 0 0.4 0.4 50 4 49 305 6 0 6 0 -10.7 0.1 -10.4 -10.9 04/20/2005 04:40:00 3.6 0.3 4.2 2.6 3.7 0.3 4.6 3 0.4 0 0.4 0.4 49 3 53 305 6 0 6 0 -10.9 0.2 -10 -11.3 04/20/2005 04:50:00 3.3 0.3 4.2 2.6 3.3 0.3 4.2 2.6 0.4 0 0.4 0.4 52 5 51 305 6 0 6 0 -10.4 0 -10 -10.7 04/20/2005 05:00:00 3 0.2 3.8 2.3 3 0.2 3.4 2.6 0.4 0 0.4 0.4 52 4 49 305 6 0 7 0 -10.8 0 -10.4 -10.9 04/20/2005 05:10:00 3 0.2 3.8 2.3 3.1 0.2 3.8 2.6 0.4 0 0.4 0.4 50 4 55 305 6 0 6 0 -10.9 0.1 -10.7 -11.3 04/20/2005 05:20:00 2.8 0.3 3.4 2.3 2.9 0.3 3.4 1.9 0.4 0 0.4 0.4 55 4 57 305 6 0 6 0 -10.7 0 -10.4 -10.9 04/20/2005 05:30:00 2.6 0.4 3.8 1.9 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 50 5 50 305 6 0 6 0 -10.4 0 -10.4 -10.7 04/20/2005 05:40:00 2.3 0.2 3 1.5 2.3 0.2 3 1.5 0.4 0 0.4 0.4 48 8 41 305 6 0 6 0 -10.4 0 -10.2 -10.4 04/20/2005 05:50:00 2.4 0.3 3 1.5 2.4 0.3 3 1.9 0.4 0 0.4 0.4 48 7 51 305 6 0 6 0 -10.4 0.1 -10.2 -10.9 04/20/2005 06:00:00 2.6 0.3 3 1.9 2.6 0.3 3.4 1.9 0.4 0 0.4 0.4 56 5 62 305 6 0 6 0 -10.8 0 -10.7 -10.9 04/20/2005 06:10:00 2.6 0.2 3 1.9 2.7 0.2 3.4 1.9 0.4 0 0.4 0.4 47 4 52 305 6 0 6 0 -11 0.1 -10.7 -11.3 04/20/2005 06:20:00 2.6 0.3 3 1.9 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 48 4 48 305 6 0 6 0 -11.1 0.2 -10.7 -11.5 04/20/2005 06:30:00 2.2 0.3 2.6 1.5 2.3 0.3 2.6 1.9 0.4 0 0.4 0.4 46 4 47 305 6 0 6 0 -10.8 0.1 -10.4 -11.1 04/20/2005 06:40:00 2.3 0.3 3 1.5 2.4 0.3 3.4 1.9 0.4 0 0.4 0.4 41 4 42 305 6 0 6 0 -10.7 0 -10.4 -10.9 04/20/2005 06:50:00 2.5 0.2 3 1.9 2.5 0.2 3 1.9 0.4 0 0.4 0.4 38 5 42 305 6 0 6 0 -10.6 0.1 -10.4 -10.9 04/20/2005 07:00:00 2.9 0.3 3.8 1.9 2.9 0.3 3.8 1.9 0.4 0 0.4 0.4 40 6 48 305 6 0 6 0 -10.6 0 -10.4 -10.9 04/20/2005 07:10:00 2.9 0.4 3.8 2.3 3 0.3 3.8 2.3 0.4 0 0.4 0.4 39 6 40 305 6 0 6 0 -10.3 0.2 -9.6 -10.9 04/20/2005 07:20:00 2.9 0.3 3.8 1.9 2.9 0.3 4.2 2.3 0.4 0 0.4 0.4 39 6 39 305 7 0 6 0 -10 0 -9.6 -10.2 04/20/2005 07:30:00 2.8 0.3 3.8 2.3 2.8 0.3 3.8 2.3 0.4 0 0.4 0.4 41 7 53 305 7 0 7 0 -9.9 0.1 -9.6 -10.2 04/20/2005 07:40:00 2.8 0.4 4.2 1.9 3 0.4 4.2 2.3 0.4 0 0.4 0.4 42 5 51 305 7 0 7 0 -9.7 0.1 -9.2 -10 04/20/2005 07:50:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 43 6 53 305 7 0 7 0 -9.8 0.1 -9.4 -10 04/20/2005 08:00:00 2.4 0.3 3.4 1.9 2.5 0.3 3.4 1.9 0.4 0 0.4 0.4 42 5 39 305 8 0 8 0 -9.9 0 -9.6 -10.2 04/20/2005 08:10:00 2.2 0.2 2.6 1.5 2.3 0.2 3 1.9 0.4 0 0.4 0.4 39 3 40 305 8 0 8 0 -9.8 0 -9.4 -10 04/20/2005 08:20:00 2.2 0.2 2.6 1.5 2.3 0.2 2.6 1.9 0.4 0 0.4 0.4 42 5 35 305 8 0 8 0 -9.9 0 -9.4 -10 04/20/2005 08:30:00 2.3 0.3 3 1.5 2.4 0.2 3 1.9 0.4 0 0.4 0.4 47 4 35 305 9 0 9 0 -9.7 0.1 -9.2 -10 04/20/2005 08:40:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 49 4 56 305 10 0 10 0 -9.6 0 -9.2 -9.8 04/20/2005 08:50:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 51 4 54 305 10 0 10 0 -9.8 0.1 -9.2 -10 04/20/2005 09:00:00 3.2 0.4 4.2 2.3 3.2 0.3 4.2 2.3 0.4 0 0.4 0.4 59 4 64 305 11 0 11 0 -9.6 0.1 -9.2 -10 04/20/2005 09:10:00 3.5 0.3 4.6 2.6 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 56 5 56 305 11 0 11 0 -9.5 0.1 -9 -9.8 04/20/2005 09:20:00 3.6 0.3 4.6 2.6 3.7 0.3 4.6 2.6 0.4 0 0.4 0.4 55 3 55 305 12 0 12 0 -9.5 0.2 -8.8 -9.8 04/20/2005 09:30:00 3.6 0.3 4.6 3 3.7 0.3 4.6 3 0.4 0 0.4 0.4 56 3 56 305 11 0 11 0 -9.1 0.1 -8.8 -9.2 04/20/2005 09:40:00 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 0.4 0 0.4 0.4 53 4 45 305 11 0 11 0 -8.9 0.1 -8.6 -9.2 04/20/2005 09:50:00 3.2 0.3 3.8 2.6 3.2 0.2 3.8 2.6 0.4 0 0.4 0.4 57 3 56 305 12 0 12 0 -8.7 0 -8.4 -9 04/20/2005 10:00:00 3 0.2 3.4 2.6 3.1 0.2 3.4 2.6 0.4 0 0.4 0.4 55 3 54 305 12 0 12 0 -8.6 0.2 -8.2 -9.2 04/20/2005 10:10:00 2.9 0.3 3.8 2.3 3 0.2 3.4 2.3 0.4 0 0.4 0.4 53 3 51 305 12 0 12 0 -8.5 0 -8.4 -8.8 04/20/2005 10:20:00 2.8 0.4 3.8 1.9 2.9 0.3 3.8 2.3 0.4 0 0.4 0.4 55 5 51 305 12 0 13 0 -8 0.2 -7.7 -8.4 04/20/2005 10:30:00 2.9 0.3 3.4 2.3 3 0.2 3.4 2.3 0.4 0 0.4 0.4 52 4 57 305 12 0 12 0 -8.1 0.1 -7.7 -8.6 04/20/2005 10:40:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 54 4 58 305 12 0 12 0 -8.2 0.2 -7.7 -8.6 04/20/2005 10:50:00 3 0.3 3.8 2.3 3 0.3 3.8 2.3 0.4 0 0.4 0.4 50 5 49 305 11 0 12 0 -7.7 0 -7.7 -7.9 04/20/2005 11:00:00 2.8 0.3 3.4 1.9 2.9 0.2 3.4 2.3 0.4 0 0.4 0.4 53 5 49 305 11 0 11 0 -7.9 0.2 -7.7 -8.2 04/20/2005 11:10:00 2.7 0.3 3.4 2.3 2.8 0.2 3.4 2.3 0.4 0 0.4 0.4 53 3 60 305 11 0 11 0 -7.6 0 -7.3 -7.7 04/20/2005 11:20:00 2.5 0.3 3 1.9 2.5 0.3 3 1.9 0.4 0 0.4 0.4 54 4 53 305 12 0 11 0 -7.7 0 -7.3 -7.9 04/20/2005 11:30:00 2.3 0.2 3 1.5 2.4 0.2 3 1.9 0.4 0 0.4 0.4 57 4 55 305 12 0 12 0 -7.5 0.1 -7.3 -7.9 04/20/2005 11:40:00 2.3 0.2 3 1.5 2.3 0.2 3 1.5 0.4 0 0.4 0.4 51 4 50 305 12 0 12 0 -7.5 0 -7.1 -7.7 04/20/2005 11:50:00 2.5 0.5 3.8 1.5 2.4 0.4 3.8 1.9 0.4 0 0.4 0.4 51 5 38 305 12 0 11 0 -7.1 0 -6.7 -7.3 04/20/2005 12:00:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.9 0.4 0 0.4 0.4 57 5 50 305 9 1 10 0 -6.8 0.4 -5.8 -7.3 04/20/2005 12:10:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 60 5 64 305 6 1 7 0 -6.1 0.1 -5.6 -6.4 04/20/2005 12:20:00 2.4 0.3 3 1.5 2.4 0.3 3 1.5 0.4 0 0.4 0.4 62 6 60 305 4 0 5 0 -5.3 0.2 -4.9 -5.6 04/20/2005 12:30:00 2.9 0.7 4.2 1.9 3 0.6 4.6 1.9 0.4 0 0.4 0.4 48 8 49 305 3 0 3 0 -6.4 0.4 -5.6 -7.1 04/20/2005 12:40:00 3.5 0.3 4.2 2.6 3.6 0.4 4.6 2.6 0.4 0 0.4 0.4 41 5 45 305 2 0 3 0 -7.1 0 -6.7 -7.1 04/20/2005 12:50:00 3.7 0.3 4.2 3 3.7 0.3 4.6 3 0.4 0 0.4 0.4 40 6 36 305 1 0 2 0 -7 0 -6.7 -7.1 04/20/2005 13:00:00 3.2 0.4 4.2 1.9 3.4 0.4 4.6 2.6 0.4 0 0.4 0.4 44 5 39 305 1 0 1 0 -6.8 0 -6.4 -7.1 04/20/2005 13:10:00 3.5 0.3 4.6 2.6 3.6 0.3 4.6 2.6 0.4 0 0.4 0.4 45 6 49 305 1 0 1 0 -6.6 0 -6.2 -6.9 04/20/2005 13:20:00 3.9 0.4 4.9 2.6 4.1 0.4 4.9 3 0.4 0 0.4 0.4 48 5 47 305 0 0 0 0 -6.5 0 -6.2 -6.7 04/20/2005 13:30:00 3.8 0.4 4.9 3 3.9 0.4 4.9 3 0.4 0 0.4 0.4 49 4 47 305 0 0 0 0 -6.6 0 -6.4 -6.9 04/20/2005 13:40:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 46 4 46 305 0 0 0 0 -6.4 0 -6 -6.7 04/20/2005 13:50:00 3.4 0.3 4.6 2.6 3.4 0.4 4.2 2.6 0.4 0 0.4 0.4 42 6 38 305 0 0 0 0 -6.4 0 -6 -6.7 04/20/2005 14:00:00 3.5 0.5 4.6 2.3 3.5 0.5 4.9 2.3 0.4 0 0.4 0.4 43 8 61 305 0 0 0 0 -6.2 0 -5.8 -6.4 04/20/2005 14:10:00 3.4 0.4 4.6 2.3 3.5 0.4 4.6 2.6 0.4 0 0.4 0.4 48 5 55 305 0 0 0 0 -6.2 0 -5.8 -6.2 04/20/2005 14:20:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 0.4 0 0.4 0.4 51 6 53 305 0 0 0 0 -6.1 0.1 -5.6 -6.2 04/20/2005 14:30:00 3.3 0.3 4.2 2.6 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 52 4 54 305 0 0 0 0 -5.9 0.1 -5.3 -6.2 04/20/2005 14:40:00 3.4 0.4 4.2 2.3 3.4 0.4 4.2 2.3 0.4 0 0.4 0.4 53 4 54 305 0 0 0 0 -5.8 0.1 -5.1 -6 04/20/2005 14:50:00 3.8 0.3 4.6 3 3.9 0.3 4.6 3 0.4 0 0.4 0.4 45 4 41 305 0 0 0 0 -5.9 0 -5.3 -6.2 04/20/2005 15:00:00 4.2 0.4 5.3 3.4 4.3 0.4 5.3 3.4 0.4 0 0.4 0.4 47 5 43 305 0 0 0 0 -5.9 0.1 -5.6 -6 04/20/2005 15:10:00 3.6 0.5 4.6 2.6 3.8 0.5 4.9 2.6 0.4 0 0.4 0.4 39 5 50 305 0 0 0 0 -6.1 0 -5.6 -6.2 04/20/2005 15:20:00 3.7 0.3 4.6 3 3.9 0.3 4.6 3 0.4 0 0.4 0.4 40 4 40 305 0 0 0 0 -6 0 -5.6 -6 04/20/2005 15:30:00 3.6 0.3 4.6 3 3.7 0.3 4.6 3 0.4 0 0.4 0.4 40 5 47 305 0 0 0 0 -6 0 -5.6 -6.2 04/20/2005 15:40:00 3.7 0.4 4.6 2.6 3.8 0.4 4.9 3 0.4 0 0.4 0.4 36 4 37 305 0 0 0 0 -5.9 0 -5.6 -6 04/20/2005 15:50:00 3.5 0.3 4.2 2.6 3.6 0.3 4.6 3 0.4 0 0.4 0.4 31 5 27 305 0 0 0 0 -5.8 0 -5.3 -6 04/20/2005 16:00:00 3.4 0.3 4.2 2.6 3.5 0.4 4.6 3 0.4 0 0.4 0.4 37 5 43 305 0 0 0 0 -5.7 0 -5.1 -5.8 04/20/2005 16:10:00 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.3 0.4 0 0.4 0.4 31 7 29 305 0 0 0 0 -5.7 0 -5.1 -5.8 04/20/2005 16:20:00 3.2 0.3 3.8 2.6 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 30 6 31 305 0 0 0 0 -5.7 0 -5.1 -5.8 04/20/2005 16:30:00 3.4 0.6 4.6 1.9 3.5 0.7 4.9 2.3 0.4 0 0.4 0.4 26 6 25 305 0 0 0 0 -5.7 0.2 -5.1 -6 04/20/2005 16:40:00 3.6 0.4 4.6 2.6 3.7 0.5 4.6 2.6 0.4 0 0.4 0.4 31 7 26 305 0 0 0 0 -5.8 0 -5.3 -6 04/20/2005 16:50:00 3.7 0.4 4.2 2.3 3.7 0.4 4.6 2.6 0.4 0 0.4 0.4 25 4 27 305 0 0 0 0 -5.7 0 -5.3 -5.8 04/20/2005 17:00:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 0.4 0 0.4 0.4 31 4 32 305 0 0 0 0 -5.8 0 -5.3 -5.8 04/20/2005 17:10:00 3.4 0.4 4.6 2.6 3.5 0.4 4.6 2.6 0.4 0 0.4 0.4 32 6 24 305 0 0 0 0 -5.6 0.1 -5.1 -5.8 04/20/2005 17:20:00 4.1 0.3 4.9 3.4 4.1 0.4 4.9 3.4 0.4 0 0.4 0.4 30 2 29 305 0 0 0 0 -5.8 0.2 -5.1 -6.2 04/20/2005 17:30:00 3.9 0.3 4.6 3 4 0.3 4.6 3 0.4 0 0.4 0.4 34 5 33 305 0 0 0 0 -6 0 -5.6 -6.2 04/20/2005 17:40:00 2.8 0.3 3.4 2.3 2.9 0.4 3.8 2.3 0.4 0 0.4 0.4 46 6 43 305 0 0 0 0 -5.6 0.2 -4.9 -6 04/20/2005 17:50:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 0.4 0 0.4 0.4 45 6 40 305 0 0 0 0 -5.4 0 -4.9 -5.8 04/20/2005 18:00:00 3.6 0.4 4.9 2.6 3.7 0.4 4.9 2.6 0.4 0 0.4 0.4 36 5 30 305 0 0 0 0 -5.9 0.1 -5.6 -6 04/20/2005 18:10:00 4.4 0.4 5.3 3 4.4 0.5 5.7 3.4 0.4 0 0.4 0.4 29 5 29 305 0 0 0 0 -5.9 0 -5.6 -6 04/20/2005 18:20:00 4.5 0.4 5.3 3.8 4.5 0.4 5.7 3.4 0.4 0 0.4 0.4 33 4 37 305 0 0 0 0 -5.9 0.1 -5.3 -6 04/20/2005 18:30:00 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.6 0.4 0 0.4 0.4 35 3 31 305 0 0 0 0 -5.9 0 -5.6 -6 04/20/2005 18:40:00 3.9 0.3 4.6 3 4 0.3 4.6 3.4 0.4 0 0.4 0.4 38 4 32 305 0 0 0 0 -6 0 -5.6 -6.2 04/20/2005 18:50:00 3.3 0.3 4.2 2.6 3.3 0.3 4.2 2.6 0.4 0 0.4 0.4 43 4 46 305 0 0 0 0 -5.8 0.1 -5.1 -6.2 04/20/2005 19:00:00 3 0.4 4.2 2.3 3 0.4 4.2 2.3 0.4 0 0.4 0.4 39 6 31 305 0 0 0 0 -5.5 0 -4.9 -5.6 04/20/2005 19:10:00 3.6 0.4 4.6 2.6 3.5 0.5 4.6 2.6 0.4 0 0.4 0.4 38 6 35 305 0 0 0 0 -5.6 0.3 -4.9 -6.2 04/20/2005 19:20:00 4.2 0.3 4.9 3.4 4.4 0.3 4.9 3.4 0.4 0 0.4 0.4 38 3 39 305 0 0 0 0 -6.4 0.1 -5.8 -6.7 04/20/2005 19:30:00 3.8 0.2 4.6 3.4 3.9 0.3 4.6 3 0.4 0 0.4 0.4 38 3 37 305 0 0 0 0 -6.5 0 -6 -6.7 04/20/2005 19:40:00 3.5 0.4 4.2 2.6 3.6 0.4 4.6 2.6 0.4 0 0.4 0.4 42 7 35 305 0 0 0 0 -6.7 0 -6.2 -6.9 04/20/2005 19:50:00 3.3 0.2 3.8 2.6 3.3 0.2 3.8 2.6 0.4 0 0.4 0.4 48 4 50 305 0 0 0 0 -7 0.1 -6.4 -7.1 04/20/2005 20:00:00 3.3 0.2 3.8 2.6 3.3 0.2 3.8 2.6 0.4 0 0.4 0.4 50 4 43 305 0 0 0 0 -7.2 0 -7.1 -7.3 04/20/2005 20:10:00 3.1 0.3 3.8 2.6 3.1 0.2 3.8 2.6 0.4 0 0.4 0.4 54 3 55 305 0 0 0 0 -7.1 0 -7.1 -7.3 04/20/2005 20:20:00 3.3 0.3 3.8 2.6 3.2 0.3 3.8 2.3 0.4 0 0.4 0.4 60 4 53 305 0 0 0 0 -7.2 0 -7.1 -7.3 04/20/2005 20:30:00 3.5 0.3 4.2 2.3 3.3 0.3 4.2 2.6 0.4 0 0.4 0.4 57 4 49 305 0 0 0 0 -7.1 0 -6.9 -7.3 04/20/2005 20:40:00 3.1 0.3 3.8 2.3 3 0.3 3.8 2.3 0.4 0 0.4 0.4 56 4 67 305 0 0 0 0 -7.1 0 -6.9 -7.1 04/20/2005 20:50:00 2.9 0.3 3.8 2.3 3 0.3 3.8 2.3 0.4 0 0.4 0.4 54 3 54 305 0 0 0 0 -7.1 0 -6.9 -7.3 04/20/2005 21:00:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 54 4 51 305 0 0 0 0 -7.1 0 -6.4 -7.3 04/20/2005 21:10:00 3.3 0.2 3.8 2.6 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 50 3 51 305 0 0 0 0 -7.5 0.2 -6.9 -7.7 04/20/2005 21:20:00 3.2 0.2 3.8 2.6 3.4 0.2 4.2 2.6 0.4 0 0.4 0.4 50 3 54 305 0 0 0 0 -7.8 0 -7.3 -7.9 04/20/2005 21:30:00 3.6 0.2 4.2 3 3.7 0.3 4.6 3 0.4 0 0.4 0.4 46 3 43 305 0 0 0 0 -7.9 0 -7.3 -8.2 04/20/2005 21:40:00 3.6 0.2 4.2 3 3.8 0.2 4.2 3.4 0.4 0 0.4 0.4 43 3 43 305 0 0 0 0 -8.2 0 -7.7 -8.4 04/20/2005 21:50:00 3.8 0.2 4.6 3 3.9 0.2 4.6 3 0.4 0 0.4 0.4 44 3 45 305 0 0 0 0 -8.5 0 -7.9 -8.6 04/20/2005 22:00:00 3.8 0.2 4.6 3.4 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 48 4 50 305 0 0 0 0 -8.6 0.1 -7.9 -8.8 04/20/2005 22:10:00 3.8 0.2 4.2 3.4 3.9 0.2 4.2 3.4 0.4 0 0.4 0.4 50 3 50 305 0 0 0 0 -8.6 0 -8.4 -8.8 04/20/2005 22:20:00 4 0.2 4.6 3.4 4.1 0.2 4.6 3.4 0.4 0 0.4 0.4 47 2 46 305 0 0 0 0 -8.6 0.1 -8.2 -8.8 04/20/2005 22:30:00 3.9 0.2 4.2 3.4 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 51 2 47 305 0 0 0 0 -8.9 0.1 -8.2 -9.2 04/20/2005 22:40:00 4 0.3 4.6 3.4 4 0.3 4.9 3 0.4 0 0.4 0.4 53 3 54 305 0 0 0 0 -8.9 0.2 -8.2 -9.2 04/20/2005 22:50:00 3.9 0.3 4.6 3.4 4 0.3 4.9 3.4 0.4 0 0.4 0.4 56 3 51 305 0 0 0 0 -8.4 0 -7.9 -8.6 04/20/2005 23:00:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 0.4 0 0.4 0.4 55 4 55 305 0 0 0 0 -8.5 0.1 -7.9 -8.8 04/20/2005 23:10:00 4.2 0.4 4.9 3.4 4.2 0.4 4.9 3.4 0.4 0 0.4 0.4 55 4 60 305 1 0 0 0 -8.3 0 -7.9 -8.6 04/20/2005 23:20:00 4.5 0.3 5.3 3.4 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 54 3 56 305 1 0 1 0 -8.3 0.1 -7.9 -8.8 04/20/2005 23:30:00 4.3 0.3 4.9 3.4 4.4 0.3 5.3 3.8 0.4 0 0.4 0.4 52 5 45 305 1 0 1 0 -8.5 0 -8.2 -8.8 04/20/2005 23:40:00 4 0.2 4.6 3.4 4.1 0.2 4.6 3.4 0.4 0 0.4 0.4 51 3 52 305 1 0 1 0 -8.3 0.1 -7.9 -8.6 04/20/2005 23:50:00 4.1 0.3 4.6 3.4 4.2 0.3 4.9 3.4 0.4 0 0.4 0.4 50 3 51 305 1 0 1 0 -8.6 0 -8.2 -8.8 04/21/2005 00:00:00 3.8 0.2 4.6 3 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 51 3 45 305 1 0 1 0 -9 0 -8.4 -9.2 04/21/2005 00:10:00 3.7 0.3 4.6 3 3.7 0.3 4.6 3 0.4 0 0.4 0.4 52 4 60 305 1 0 1 0 -8.9 0.2 -8.6 -9.2 04/21/2005 00:20:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 0.4 0 0.4 0.4 52 4 50 305 1 0 1 0 -8.5 0 -8.4 -8.8 04/21/2005 00:30:00 3.5 0.3 4.6 2.6 3.5 0.3 4.6 3 0.4 0 0.4 0.4 51 4 48 305 1 0 1 0 -8.4 0 -8.2 -8.6 04/21/2005 00:40:00 3.4 0.3 4.2 3 3.5 0.2 4.2 3 0.4 0 0.4 0.4 53 3 52 305 1 0 1 0 -8.6 0 -8.4 -8.8 04/21/2005 00:50:00 3.5 0.2 4.2 3 3.5 0.2 4.2 2.6 0.4 0 0.4 0.4 55 4 49 305 1 0 1 0 -8.8 0 -8.8 -9 04/21/2005 01:00:00 3.6 0.3 4.2 3 3.7 0.3 4.6 3 0.4 0 0.4 0.4 55 3 56 305 1 0 1 0 -8.7 0 -8.6 -8.8 04/21/2005 01:10:00 3.6 0.2 4.2 3 3.6 0.3 4.2 3 0.4 0 0.4 0.4 56 4 56 305 1 0 1 0 -8.7 0 -8.4 -8.8 04/21/2005 01:20:00 3.3 0.3 4.2 2.6 3.3 0.3 4.2 2.6 0.4 0 0.4 0.4 57 4 58 305 1 0 1 0 -8.7 0.2 -8.2 -9.2 04/21/2005 01:30:00 3.2 0.3 3.8 2.6 3.4 0.2 4.2 2.6 0.4 0 0.4 0.4 53 4 54 305 2 0 2 0 -8.2 0 -7.9 -8.2 04/21/2005 01:40:00 3.2 0.3 4.2 2.3 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 46 5 49 305 1 0 1 0 -8.4 0.1 -7.9 -8.8 04/21/2005 01:50:00 3.4 0.2 4.2 3 3.5 0.2 4.2 3 0.4 0 0.4 0.4 42 4 26 305 1 0 1 0 -8.5 0.1 -8.4 -8.8 04/21/2005 02:00:00 3.8 0.5 4.9 3 3.9 0.3 4.9 3 0.4 0 0.4 0.4 43 4 35 305 1 0 1 0 -8.6 0.3 -8.2 -9.2 04/21/2005 02:10:00 3.7 0.2 4.2 3 3.8 0.2 4.2 3 0.4 0 0.4 0.4 46 3 46 305 1 0 1 0 -8.9 0.2 -8.6 -9.2 04/21/2005 02:20:00 4.1 0.3 4.9 3.4 4.2 0.4 5.3 3.4 0.4 0 0.4 0.4 45 5 40 305 1 0 1 0 -8.8 0 -8.6 -9 04/21/2005 02:30:00 4.3 0.3 4.9 3.8 4.4 0.3 5.3 3.8 0.4 0 0.4 0.4 42 4 36 305 2 0 2 0 -8.7 0 -8.4 -9 04/21/2005 02:40:00 3.9 0.2 4.6 3.4 4 0.2 4.6 3.4 0.4 0 0.4 0.4 46 5 44 305 2 0 2 0 -8.6 0.2 -8.2 -9 04/21/2005 02:50:00 4.5 0.4 5.7 3.4 4.5 0.4 5.3 3.4 0.4 0 0.4 0.4 48 5 48 305 2 0 2 0 -8.5 0.1 -8.2 -8.8 04/21/2005 03:00:00 4.6 0.4 5.7 3.8 4.7 0.4 5.7 3.4 0.4 0 0.4 0.4 46 5 49 305 2 0 2 0 -8.3 0 -8.2 -8.4 04/21/2005 03:10:00 4.8 0.4 6.1 3.8 4.8 0.4 5.7 4.2 0.4 0 0.4 0.4 44 4 46 305 2 0 2 0 -8.6 0.1 -8.2 -8.8 04/21/2005 03:20:00 4.3 0.3 4.9 3.4 4.4 0.3 4.9 3.8 0.4 0 0.4 0.4 46 4 49 305 2 0 2 0 -8.6 0 -8.4 -8.8 04/21/2005 03:30:00 4.6 0.3 5.7 3.8 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 49 4 46 305 2 0 2 0 -8.7 0.1 -8.4 -9 04/21/2005 03:40:00 4.7 0.5 6.1 3.8 4.7 0.5 6.5 3.8 0.4 0 0.4 0.4 50 5 49 305 2 0 2 0 -8.5 0.1 -8.2 -8.8 04/21/2005 03:50:00 4.8 0.4 6.1 3.8 4.8 0.4 6.1 3.8 0.4 0 0.4 0.4 51 5 51 305 2 0 2 0 -8.6 0.1 -8.2 -8.8 04/21/2005 04:00:00 4.9 0.5 6.1 3.8 4.9 0.5 6.1 3.8 0.4 0 0.4 0.4 53 5 56 305 2 0 2 0 -8.6 0 -8.4 -8.8 04/21/2005 04:10:00 4.9 0.4 6.1 3.8 4.9 0.5 6.1 3.8 0.4 0 0.4 0.4 52 5 46 305 2 0 2 0 -8.4 0 -8.2 -8.6 04/21/2005 04:20:00 5.1 0.3 5.7 4.2 5.1 0.4 6.1 4.2 0.4 0 0.4 0.4 50 4 48 305 2 0 2 0 -8.5 0.1 -8.2 -8.8 04/21/2005 04:30:00 4.9 0.3 5.7 4.2 5 0.3 5.7 4.6 0.4 0 0.4 0.4 47 3 48 305 2 0 2 0 -8.9 0.1 -8.4 -9.2 04/21/2005 04:40:00 5.1 0.3 6.1 4.6 5 0.3 6.1 4.2 0.4 0 0.4 0.4 41 4 38 305 2 0 2 0 -9.3 0 -8.8 -9.4 04/21/2005 04:50:00 5.8 0.4 6.8 4.9 5.7 0.4 6.8 4.6 0.4 0 0.4 0.4 41 3 38 305 2 0 2 0 -9.3 0.1 -9 -9.6 04/21/2005 05:00:00 6 0.3 6.8 5.3 5.8 0.3 6.8 4.9 0.4 0 0.4 0.4 40 3 40 305 2 0 2 0 -9.4 0 -9 -9.6 04/21/2005 05:10:00 5.7 0.3 6.5 4.6 5.6 0.3 6.5 4.6 0.4 0 0.4 0.4 47 4 39 305 2 0 2 0 -9.5 0 -9.2 -9.6 04/21/2005 05:20:00 5.6 0.3 6.8 4.9 5.6 0.4 6.5 4.9 0.4 0 0.4 0.4 48 4 36 305 2 0 2 0 -9.1 0 -8.8 -9.2 04/21/2005 05:30:00 5.4 0.3 6.5 4.6 5.4 0.3 6.5 4.9 0.4 0 0.4 0.4 50 4 53 305 2 0 2 0 -9.3 0 -9 -9.4 04/21/2005 05:40:00 5.6 0.5 6.8 4.2 5.5 0.5 7.2 3.8 0.4 0 0.4 0.4 55 6 38 305 3 0 2 0 -8.9 0.1 -8.8 -9.2 04/21/2005 05:50:00 6.1 0.5 7.6 4.9 6 0.5 7.6 4.9 0.4 0 0.4 0.4 52 5 41 305 3 0 3 0 -8.9 0.1 -8.6 -9.2 04/21/2005 06:00:00 5.9 0.4 6.8 4.9 5.8 0.3 6.5 4.9 0.4 0 0.4 0.4 47 4 49 305 3 0 3 0 -9.1 0.2 -8.8 -9.6 04/21/2005 06:10:00 5.5 0.6 7.2 4.2 5.4 0.5 6.8 4.2 0.4 0 0.4 0.4 53 6 53 305 2 0 2 0 -9.5 0.1 -9.2 -9.8 04/21/2005 06:20:00 6.1 0.5 7.2 4.9 6.1 0.5 7.6 4.6 0.4 0 0.4 0.4 59 4 58 305 3 0 2 0 -9.3 0.1 -8.8 -9.6 04/21/2005 06:30:00 6.2 0.5 7.6 4.9 6.3 0.4 7.6 5.3 0.4 0 0.4 0.4 59 5 57 305 3 0 2 0 -9.1 0.1 -8.8 -9.2 04/21/2005 06:40:00 5.4 0.5 6.8 4.2 5.4 0.4 6.5 4.6 0.4 0 0.4 0.4 57 5 60 305 3 0 3 0 -9.2 0 -8.8 -9.2 04/21/2005 06:50:00 5.8 0.6 7.2 4.6 5.8 0.6 6.8 4.2 0.4 0 0.4 0.4 59 5 67 305 3 0 3 0 -9.3 0 -9.2 -9.4 04/21/2005 07:00:00 5.9 0.5 7.2 4.6 5.7 0.5 7.6 4.2 0.4 0 0.4 0.4 51 4 48 305 2 0 2 0 -9.7 0.1 -9.2 -10 04/21/2005 07:10:00 6.2 0.4 6.8 5.3 6 0.4 6.8 4.9 0.4 0 0.4 0.4 50 3 53 305 2 0 2 0 -10 0 -9.8 -10.2 04/21/2005 07:20:00 5.7 0.4 6.5 4.6 5.5 0.4 6.5 4.6 0.4 0 0.4 0.4 49 3 50 305 2 0 2 0 -10.1 0 -9.8 -10.4 04/21/2005 07:30:00 6.1 0.5 7.6 4.6 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 45 5 40 305 2 0 2 0 -9.9 0 -9.8 -10.2 04/21/2005 07:40:00 6.8 0.6 8 5.3 6.5 0.6 8 5.3 0.4 0 0.4 0.4 42 3 46 305 2 0 2 0 -9.7 0.1 -9.4 -9.8 04/21/2005 07:50:00 7.4 0.5 8.4 6.1 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 43 4 43 305 2 0 2 0 -9.4 0 -9.2 -9.6 04/21/2005 08:00:00 7.5 0.6 9.5 6.1 7.2 0.6 9.5 5.7 0.4 0 0.4 0.4 44 4 37 305 2 0 2 0 -9.5 0 -9.2 -9.6 04/21/2005 08:10:00 7.2 0.6 9.1 6.1 7 0.5 8.8 5.7 0.4 0 0.4 0.4 42 3 47 305 2 0 2 0 -9.5 0 -9.2 -9.6 04/21/2005 08:20:00 8.3 0.7 9.9 6.5 8 0.7 9.9 6.5 0.4 0 0.4 0.4 42 4 45 305 2 0 1 0 -9.3 0 -8.8 -9.6 04/21/2005 08:30:00 8.4 0.6 9.9 6.8 8.1 0.6 9.9 6.5 0.4 0 0.4 0.4 42 4 44 305 1 0 1 0 -9.2 0.1 -8.8 -9.2 04/21/2005 08:40:00 8.3 0.6 9.9 6.8 8.1 0.6 9.9 6.8 0.4 0 0.4 0.4 39 4 36 305 1 0 1 0 -9 0 -8.8 -9.2 04/21/2005 08:50:00 8.6 0.7 10.3 6.8 8.3 0.8 10.7 6.1 0.4 0 0.4 0.4 42 5 42 305 1 0 1 0 -9 0 -8.8 -9.2 04/21/2005 09:00:00 9.7 0.6 11.1 8 9.4 0.7 11.1 7.6 0.4 0 0.4 0.4 43 4 46 305 1 0 1 0 -9 0 -8.8 -9.2 04/21/2005 09:10:00 9.4 0.6 11.5 7.6 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 43 4 40 305 1 0 1 0 -8.9 0 -8.8 -9.2 04/21/2005 09:20:00 9.5 0.5 10.7 8 9.4 0.6 11.1 8 0.4 0 0.4 0.4 41 4 56 305 1 0 1 0 -8.9 0 -8.8 -9 04/21/2005 09:30:00 9.3 0.8 11.5 7.2 9 0.8 10.7 6.8 0.4 0 0.4 0.4 41 5 46 305 1 0 1 0 -8.9 0 -8.6 -9.2 04/21/2005 09:40:00 9.7 0.6 11.5 8 9.5 0.6 11.1 8 0.4 0 0.4 0.4 47 4 46 305 1 0 1 0 -8.9 0 -8.6 -9.2 04/21/2005 09:50:00 8.8 0.7 10.3 7.2 8.5 0.7 10.7 6.5 0.4 0 0.4 0.4 45 4 42 305 1 0 1 0 -8.8 0 -8.6 -9 04/21/2005 10:00:00 9 0.8 11.1 6.8 8.8 0.9 10.7 6.5 0.4 0 0.4 0.4 43 5 44 305 1 0 1 0 -8.7 0 -8.4 -8.8 04/21/2005 10:10:00 9.2 0.7 11.1 6.8 9 0.7 11.1 7.2 0.4 0 0.4 0.4 44 5 41 305 1 0 1 0 -8.7 0 -8.4 -8.8 04/21/2005 10:20:00 9.4 0.8 11.1 7.6 9.2 0.9 11.1 7.6 0.4 0 0.4 0.4 44 4 47 305 0 0 1 0 -8.8 0 -8.4 -8.8 04/21/2005 10:30:00 9.3 0.9 11.5 7.6 9.1 0.9 11.1 7.2 0.4 0 0.4 0.4 40 5 39 305 0 0 0 0 -8.7 0 -8.6 -8.8 04/21/2005 10:40:00 9.2 0.8 11.1 7.2 9 0.8 11.1 6.5 0.4 0 0.4 0.4 38 5 34 305 0 0 0 0 -8.7 0 -8.4 -8.8 04/21/2005 10:50:00 9.1 0.8 11.1 6.8 8.8 0.8 10.7 6.8 0.4 0 0.4 0.4 34 5 29 305 0 0 0 0 -8.6 0 -8.4 -8.8 04/21/2005 11:00:00 9.1 0.8 11.5 7.2 9 0.8 11.1 6.8 0.4 0 0.4 0.4 35 5 38 305 0 0 0 0 -8.6 0 -8.4 -8.8 04/21/2005 11:10:00 9.8 0.8 11.5 7.2 9.7 0.8 11.5 7.2 0.4 0 0.4 0.4 36 5 40 305 0 0 0 0 -8.6 0 -8.4 -8.8 04/21/2005 11:20:00 10.7 0.5 12.2 9.1 10.6 0.7 11.8 8 0.4 0 0.4 0.4 40 3 39 305 0 0 0 0 -8.6 0 -8.4 -8.8 04/21/2005 11:30:00 10.3 0.8 11.8 8 10.2 0.8 11.8 8 0.4 0 0.4 0.4 38 5 32 305 0 0 0 0 -8.5 0 -8.4 -8.8 04/21/2005 11:40:00 10 1.2 12.2 7.2 9.8 1.2 12.2 6.8 0.4 0 0.4 0.4 37 5 34 305 0 0 0 0 -8.4 0 -8.2 -8.6 04/21/2005 11:50:00 11 0.6 12.2 9.1 10.9 0.7 12.6 9.1 0.4 0 0.4 0.4 40 4 49 305 0 0 0 0 -8.5 0 -8.4 -8.8 04/21/2005 12:00:00 10.4 0.8 12.6 8 10.2 0.9 12.6 8 0.4 0 0.4 0.4 40 6 35 305 0 0 0 0 -8.4 0 -8.2 -8.6 04/21/2005 12:10:00 10.8 0.8 12.6 8 10.6 0.9 12.2 8 0.4 0 0.4 0.4 40 5 35 305 0 0 0 0 -8.4 0 -8.2 -8.6 04/21/2005 12:20:00 10.4 1.1 12.6 7.6 10.2 1.1 12.6 7.2 0.4 0 0.4 0.4 43 5 47 305 0 0 0 0 -8.3 0 -8.2 -8.4 04/21/2005 12:30:00 10.9 0.9 12.6 8.8 10.8 1 13 8 0.4 0 0.4 0.4 45 6 45 305 0 0 0 0 -8.3 0 -8.2 -8.4 04/21/2005 12:40:00 11.3 0.8 13 8.8 11.2 0.9 13 8.8 0.4 0 0.4 0.4 39 4 35 305 0 0 0 0 -8.3 0 -8.2 -8.4 04/21/2005 12:50:00 11.5 0.9 13.3 9.1 11.4 1 13.3 8 0.4 0 0.4 0.4 39 4 34 305 0 0 0 0 -8.3 0 -8.2 -8.4 04/21/2005 13:00:00 10.9 0.7 12.2 9.1 10.7 0.8 12.6 8.4 0.4 0 0.4 0.4 36 5 36 305 0 0 0 0 -8.2 0 -7.9 -8.4 04/21/2005 13:10:00 11.3 0.7 13 9.5 11.3 0.8 13 9.1 0.4 0 0.4 0.4 36 5 29 305 0 0 0 0 -8.2 0 -7.9 -8.4 04/21/2005 13:20:00 11.1 0.8 13 8.8 10.9 0.8 12.6 8.4 0.4 0 0.4 0.4 38 5 37 305 0 0 0 0 -8.2 0 -7.9 -8.4 04/21/2005 13:30:00 11.7 0.9 13.7 9.1 11.6 1 13.7 8.8 0.4 0 0.4 0.4 36 6 36 305 0 0 0 0 -8.2 0 -7.9 -8.2 04/21/2005 13:40:00 12 0.7 13.3 9.9 11.8 0.7 13.3 9.5 0.4 0 0.4 0.4 35 5 38 305 0 0 0 0 -8.2 0 -7.9 -8.2 04/21/2005 13:50:00 11.2 1.2 13.3 8.4 11.1 1.2 13.7 8 0.4 0 0.4 0.4 35 5 35 305 0 0 0 0 -8 0.1 -7.7 -8.2 04/21/2005 14:00:00 11.8 0.9 13.7 9.5 11.6 1 14.1 8.4 0.4 0 0.4 0.4 33 6 32 305 0 0 0 0 -8 0.1 -7.7 -8.2 04/21/2005 14:10:00 12 0.8 13.7 10.3 11.8 0.9 13.3 9.1 0.4 0 0.4 0.4 31 5 29 305 0 0 0 0 -8 0 -7.7 -8.2 04/21/2005 14:20:00 11.9 0.9 14.1 9.9 11.7 0.9 14.5 9.5 0.4 0 0.4 0.4 32 5 23 305 0 0 0 0 -7.9 0 -7.7 -8.2 04/21/2005 14:30:00 12.1 1.1 14.5 9.1 11.9 1.2 14.5 8.8 0.4 0 0.4 0.4 32 5 33 305 0 0 0 0 -7.8 0 -7.7 -8.2 04/21/2005 14:40:00 12.5 0.8 14.5 9.9 12.3 0.9 14.5 10.3 0.4 0 0.4 0.4 32 5 39 305 0 0 0 0 -7.8 0 -7.7 -7.9 04/21/2005 14:50:00 12.2 1.1 14.9 9.1 12 1.1 14.5 9.5 0.4 0 0.4 0.4 34 5 33 305 0 0 0 0 -7.7 0 -7.5 -7.9 04/21/2005 15:00:00 12.3 1.4 14.9 8.8 12.2 1.4 15.3 8.4 0.4 0 0.4 0.4 30 5 29 305 0 0 0 0 -7.7 0 -7.3 -7.9 04/21/2005 15:10:00 12.5 1 14.9 10.3 12.2 1.1 14.9 9.5 0.4 0 0.4 0.4 28 6 41 305 0 0 0 0 -7.6 0 -7.3 -7.7 04/21/2005 15:20:00 13.2 1.1 15.3 10.3 12.8 1.1 15.3 10.3 0.4 0 0.4 0.4 28 5 30 305 0 0 0 0 -7.7 0 -7.5 -7.7 04/21/2005 15:30:00 13 1 15.3 9.9 12.8 1 15.6 10.7 0.4 0 0.4 0.4 31 5 31 305 0 0 0 0 -7.6 0 -7.5 -7.7 04/21/2005 15:40:00 12.9 1.1 15.6 9.9 12.7 1.1 16.1 9.9 0.4 0 0.4 0.4 28 6 25 305 0 0 0 0 -7.6 0 -7.3 -7.9 04/21/2005 15:50:00 13.2 1.3 15.6 9.1 13 1.2 15.6 8.8 0.4 0 0.4 0.4 27 5 23 305 0 0 0 0 -7.7 0 -7.5 -7.9 04/21/2005 16:00:00 13 1.1 15.3 9.5 12.7 1.2 15.6 9.5 0.4 0 0.4 0.4 26 5 27 305 0 0 0 0 -7.7 0 -7.5 -7.7 04/21/2005 16:10:00 12.9 1.1 15.3 9.5 12.6 1.2 15.3 9.1 0.4 0 0.4 0.4 28 6 25 305 0 0 0 0 -7.6 0 -7.3 -7.7 04/21/2005 16:20:00 12.4 1.2 15.6 9.9 12.2 1.3 15.6 8.8 0.4 0 0.4 0.4 29 6 24 305 0 0 0 0 -7.5 0 -7.3 -7.7 04/21/2005 16:30:00 13.3 1.3 16.1 9.1 13 1.3 15.6 9.1 0.4 0 0.4 0.4 28 5 29 305 0 0 0 0 -7.6 0 -7.3 -7.7 04/21/2005 16:40:00 13.2 1.1 16.1 10.3 13 1.1 15.6 9.5 0.4 0 0.4 0.4 26 5 25 305 0 0 0 0 -7.6 0 -7.3 -7.7 04/21/2005 16:50:00 13.7 1.1 16.4 10.3 13.4 1.1 16.4 10.3 0.4 0 0.4 0.4 27 5 31 305 0 0 0 0 -7.7 0 -7.5 -7.7 04/21/2005 17:00:00 13.8 1.1 16.4 11.1 13.5 1.2 16.4 9.9 0.4 0 0.4 0.4 26 5 22 305 0 0 0 0 -7.6 0 -7.3 -7.7 04/21/2005 17:10:00 12.7 1.4 16.4 9.1 12.3 1.5 15.6 9.1 0.4 0 0.4 0.4 27 5 31 305 0 0 0 0 -7.5 0 -7.3 -7.7 04/21/2005 17:20:00 13.5 1.4 16.4 9.9 13.2 1.3 16.1 10.3 0.4 0 0.4 0.4 29 5 34 305 0 0 0 0 -7.6 0 -7.3 -7.7 04/21/2005 17:30:00 14.7 1 16.8 11.8 14.3 1.1 16.8 10.7 0.4 0 0.4 0.4 30 4 29 305 0 0 0 0 -7.6 0 -7.5 -7.7 04/21/2005 17:40:00 15 1 17.2 11.8 14.5 1.1 17.2 11.5 0.4 0 0.4 0.4 28 5 31 305 0 0 0 0 -7.6 0 -7.5 -7.7 04/21/2005 17:50:00 14.2 1.2 16.8 10.7 13.8 1.2 16.8 10.7 0.4 0 0.4 0.4 29 5 29 305 0 0 0 0 -7.6 0 -7.5 -7.7 04/21/2005 18:00:00 14.4 1.3 17.6 11.1 14 1.3 17.6 10.3 0.4 0 0.4 0.4 28 6 35 305 0 0 0 0 -7.5 0 -7.3 -7.7 04/21/2005 18:10:00 15 1.4 17.9 11.1 14.8 1.3 17.9 10.7 0.4 0 0.4 0.4 29 5 32 305 0 0 0 0 -7.6 0 -7.3 -7.7 04/21/2005 18:20:00 14.8 1.5 17.9 10.3 14.4 1.5 17.2 10.7 0.4 0 0.4 0.4 28 4 29 305 0 0 0 0 -7.5 0 -7.3 -7.7 04/21/2005 18:30:00 14.6 1 17.2 11.5 14.3 1.1 16.8 11.5 0.4 0 0.4 0.4 25 5 25 305 0 0 0 0 -7.5 0 -7.3 -7.7 04/21/2005 18:40:00 14.3 1.3 17.6 10.7 13.9 1.4 17.6 9.5 0.4 0 0.4 0.4 28 5 30 305 0 0 0 0 -7.5 0 -7.3 -7.7 04/21/2005 18:50:00 14.3 1.5 17.2 10.3 13.9 1.5 17.2 9.5 0.4 0 0.4 0.4 26 5 21 305 0 0 0 0 -7.7 0 -7.5 -7.9 04/21/2005 19:00:00 13.8 1.2 16.8 10.7 13.5 1.3 16.8 10.3 0.4 0 0.4 0.4 26 5 24 305 0 0 0 0 -7.7 0 -7.7 -7.9 04/21/2005 19:10:00 14.3 1.2 16.8 9.9 14.1 1.3 16.8 10.3 0.4 0 0.4 0.4 25 6 23 305 0 0 0 0 -7.7 0 -7.5 -7.9 04/21/2005 19:20:00 14.2 1.3 17.2 10.3 13.8 1.4 16.4 10.3 0.4 0 0.4 0.4 24 5 27 305 0 0 0 0 -7.7 0 -7.7 -7.9 04/21/2005 19:30:00 14.2 1.6 17.2 10.3 13.9 1.6 17.6 9.1 0.4 0 0.4 0.4 24 5 22 305 0 0 0 0 -7.7 0 -7.5 -7.9 04/21/2005 19:40:00 14.2 1.2 17.2 10.3 13.9 1.3 17.2 10.3 0.4 0 0.4 0.4 22 5 27 305 0 0 0 0 -7.9 0.1 -7.7 -8.2 04/21/2005 19:50:00 14.4 1.3 17.2 10.7 14.3 1.3 17.2 10.7 0.4 0 0.4 0.4 21 5 18 305 0 0 1 0 -8 0 -7.7 -8.2 04/21/2005 20:00:00 15 1.6 17.9 10.7 14.7 1.7 17.9 10.7 0.4 0 0.4 0.4 24 5 29 305 1 0 1 0 -7.9 0 -7.7 -8.2 04/21/2005 20:10:00 15.6 1.3 18.7 12.6 15.2 1.3 18.7 12.2 0.4 0 0.4 0.4 24 5 21 305 1 0 1 0 -8 0 -7.7 -8.2 04/21/2005 20:20:00 15.1 1.3 18.3 11.5 14.6 1.5 17.9 10.7 0.4 0 0.4 0.4 25 5 24 305 1 0 1 0 -8.2 0 -7.9 -8.2 04/21/2005 20:30:00 15.9 1.3 19.1 11.8 15.5 1.4 17.9 11.1 0.4 0 0.4 0.4 22 5 10 305 1 0 1 0 -8.3 0 -7.9 -8.4 04/21/2005 20:40:00 15.7 1.3 18.7 12.6 15.2 1.5 19.1 11.8 0.4 0 0.4 0.4 25 5 24 305 1 0 1 0 -8.3 0 -8.2 -8.4 04/21/2005 20:50:00 15.2 1.7 18.3 10.3 14.8 1.7 18.7 9.9 0.4 0 0.4 0.4 23 5 12 305 1 0 1 0 -8.3 0 -8.2 -8.6 04/21/2005 21:00:00 14.5 1.7 18.3 10.7 14.1 1.7 17.6 9.9 0.4 0 0.4 0.4 22 5 32 305 1 0 2 0 -8.3 0 -8.2 -8.4 04/21/2005 21:10:00 15.5 1.6 18.7 10.7 15.2 1.6 18.3 10.7 0.4 0 0.4 0.4 22 5 24 305 2 0 2 0 -8.4 0 -8.2 -8.6 04/21/2005 21:20:00 14.6 1.7 18.3 10.7 14.3 1.7 17.9 10.3 0.4 0 0.4 0.4 26 5 27 305 2 0 2 0 -8.3 0 -8.2 -8.4 04/21/2005 21:30:00 15.9 1.6 19.5 12.2 15.5 1.5 19.1 11.8 0.4 0 0.4 0.4 24 5 22 305 2 0 2 0 -8.4 0 -8.2 -8.6 04/21/2005 21:40:00 15.5 1.8 19.5 10.7 15.3 1.9 19.1 10.7 0.4 0 0.4 0.4 24 5 23 305 2 0 2 0 -8.4 0 -8.2 -8.6 04/21/2005 21:50:00 15.6 1.7 19.9 11.1 15 1.6 19.1 10.7 0.4 0 0.4 0.4 23 6 18 305 2 0 2 0 -8.4 0 -8.4 -8.6 04/21/2005 22:00:00 17 1.7 20.2 12.2 16.7 1.7 20.2 11.5 0.4 0 0.4 0.4 25 5 23 305 2 0 2 0 -8.6 0 -8.4 -8.8 04/21/2005 22:10:00 17.5 1.5 20.2 13 17.1 1.5 20.2 11.8 0.4 0 0.4 0.4 23 4 21 305 3 0 2 0 -8.6 0 -8.4 -8.8 04/21/2005 22:20:00 15.8 1.7 19.1 11.5 15.5 1.7 18.7 11.1 0.4 0 0.4 0.4 21 5 11 305 3 0 3 0 -8.6 0 -8.4 -8.8 04/21/2005 22:30:00 16 1.5 19.5 12.2 15.7 1.5 19.1 11.8 0.4 0 0.4 0.4 21 5 19 305 3 0 3 0 -8.6 0 -8.4 -8.8 04/21/2005 22:40:00 15.7 1.5 18.7 12.2 15.5 1.5 18.7 11.8 0.4 0 0.4 0.4 22 5 16 305 4 0 4 0 -8.6 0 -8.4 -8.6 04/21/2005 22:50:00 16.5 1.5 19.5 12.2 16.2 1.6 20.2 11.1 0.4 0 0.4 0.4 21 5 19 305 4 0 4 0 -8.5 0 -8.2 -8.6 04/21/2005 23:00:00 15.2 1.7 19.5 10.3 15 1.7 19.5 10.3 0.4 0 0.4 0.4 22 6 24 305 4 0 4 0 -8.5 0 -8.2 -8.8 04/21/2005 23:10:00 16.4 1.9 20.6 11.5 16 1.8 20.2 11.8 0.4 0 0.4 0.4 23 5 22 305 4 0 4 0 -8.6 0 -8.4 -8.8 04/21/2005 23:20:00 18 1.6 21.4 13 17.6 1.6 21.4 13.7 0.4 0 0.4 0.4 23 5 20 305 4 0 4 0 -8.7 0 -8.4 -8.8 04/21/2005 23:30:00 17.9 1.5 21.4 13.3 17.5 1.5 20.6 13.3 0.4 0 0.4 0.4 23 5 19 305 4 0 4 0 -8.7 0 -8.6 -8.8 04/21/2005 23:40:00 17.3 1.6 21.4 13.3 17 1.6 21.8 12.6 0.4 0 0.4 0.4 23 5 25 305 4 0 4 0 -8.7 0 -8.6 -8.8 04/21/2005 23:50:00 16.6 1.8 20.6 12.2 16.2 1.8 21 11.8 0.4 0 0.4 0.4 22 5 17 305 4 0 4 0 -8.7 0 -8.6 -8.8 04/22/2005 00:00:00 17.4 1.7 21 13.3 16.9 1.7 20.6 13 0.4 0 0.4 0.4 22 5 21 305 4 0 4 0 -8.8 0 -8.4 -9 04/22/2005 00:10:00 17.6 1.7 21.4 12.6 17.2 1.7 21.4 11.8 0.4 0 0.4 0.4 20 5 18 305 4 0 4 0 -8.8 0 -8.6 -9 04/22/2005 00:20:00 16.9 1.6 20.6 13 16.5 1.7 20.6 12.6 0.4 0 0.4 0.4 20 5 21 305 4 0 5 0 -8.7 0 -8.4 -8.8 04/22/2005 00:30:00 16.8 1.7 21.4 13 16.5 1.7 21 11.8 0.4 0 0.4 0.4 19 5 18 305 4 0 5 0 -8.7 0 -8.6 -8.8 04/22/2005 00:40:00 17.9 1.6 21 13.3 17.6 1.7 21 11.8 0.4 0 0.4 0.4 20 5 20 305 4 0 4 0 -8.7 0 -8.4 -8.8 04/22/2005 00:50:00 17.4 1.6 21.4 12.6 16.9 1.5 20.2 13 0.4 0 0.4 0.4 22 5 18 305 4 0 4 0 -8.6 0 -8.4 -8.8 04/22/2005 01:00:00 16.8 1.7 20.6 12.6 16.4 1.6 19.9 11.8 0.4 0 0.4 0.4 23 6 21 305 4 0 4 0 -8.5 0 -8.2 -8.8 04/22/2005 01:10:00 16.9 1.9 21.4 12.6 16.6 1.8 21 12.6 0.4 0 0.4 0.4 24 5 25 305 4 0 4 0 -8.3 0 -7.9 -8.4 04/22/2005 01:20:00 17.3 1.9 21.8 13.3 16.8 2 23.3 12.6 0.4 0 0.4 0.4 24 6 21 305 4 0 4 0 -8.2 0 -7.9 -8.4 04/22/2005 01:30:00 16.2 1.9 20.2 11.5 15.8 1.7 19.9 11.1 0.4 0 0.4 0.4 25 5 27 305 4 0 4 0 -8 0.1 -7.7 -8.2 04/22/2005 01:40:00 16.3 1.7 19.9 11.1 15.9 1.7 19.9 10.7 0.4 0 0.4 0.4 22 6 19 305 4 0 4 0 -7.9 0 -7.7 -8.2 04/22/2005 01:50:00 15.5 1.8 19.5 11.5 15.4 1.7 19.5 11.1 0.4 0 0.4 0.4 21 5 22 305 4 0 4 0 -7.9 0 -7.7 -7.9 04/22/2005 02:00:00 17 1.7 20.6 12.6 16.6 1.7 20.2 11.8 0.4 0 0.4 0.4 20 5 24 305 4 0 4 0 -7.9 0 -7.7 -8.2 04/22/2005 02:10:00 17.3 1.7 20.6 12.2 16.9 1.5 20.6 13 0.4 0 0.4 0.4 22 5 18 305 4 0 4 0 -8 0.1 -7.7 -8.2 04/22/2005 02:20:00 18.3 1.5 21.4 13 17.8 1.6 21.4 13.3 0.4 0 0.4 0.4 18 5 16 305 4 0 4 0 -8.2 0 -7.7 -8.4 04/22/2005 02:30:00 16.8 1.7 20.6 12.2 16.4 1.7 20.2 11.8 0.4 0 0.4 0.4 20 6 23 305 5 0 5 0 -8.1 0 -7.7 -8.2 04/22/2005 02:40:00 16 1.7 19.9 11.8 15.7 1.7 20.6 11.5 0.4 0 0.4 0.4 19 6 18 305 5 0 5 0 -8 0 -7.7 -8.2 04/22/2005 02:50:00 16.2 1.8 21 12.2 15.8 1.8 20.6 11.5 0.4 0 0.4 0.4 19 5 19 305 5 0 5 0 -7.9 0 -7.7 -7.9 04/22/2005 03:00:00 16.8 1.8 21.8 11.8 16.5 1.7 21 12.6 0.4 0 0.4 0.4 19 5 13 305 6 0 6 0 -7.9 0 -7.5 -7.9 04/22/2005 03:10:00 17.6 2.1 22.1 12.6 17.2 2 22.1 12.6 0.4 0 0.4 0.4 18 5 21 305 6 0 6 0 -7.8 0 -7.5 -7.9 04/22/2005 03:20:00 17.2 2.3 21.8 12.6 16.9 2.3 22.1 11.8 0.4 0 0.4 0.4 18 6 22 305 6 0 6 0 -7.7 0 -7.3 -7.9 04/22/2005 03:30:00 17 2 22.1 11.8 16.7 2 21.8 11.8 0.4 0 0.4 0.4 19 5 22 305 7 0 7 0 -7.6 0 -7.3 -7.7 04/22/2005 03:40:00 16.8 2.1 21.4 12.2 16.5 2 21 11.1 0.4 0 0.4 0.4 17 5 12 305 7 0 7 0 -7.4 0 -7.1 -7.5 04/22/2005 03:50:00 16.7 1.9 21 11.5 16.5 1.8 20.6 11.8 0.4 0 0.4 0.4 17 5 12 305 7 0 7 0 -7.4 0 -7.1 -7.5 04/22/2005 04:00:00 17 1.9 21 12.6 16.7 1.9 21.4 12.2 0.4 0 0.4 0.4 17 5 22 305 7 0 7 0 -7.2 0 -6.9 -7.3 04/22/2005 04:10:00 17.8 1.7 22.1 13.3 17.5 1.8 22.1 12.6 0.4 0 0.4 0.4 17 5 11 305 8 0 8 0 -7.1 0 -6.9 -7.3 04/22/2005 04:20:00 17 1.8 21.8 11.8 16.6 1.8 22.1 12.6 0.4 0 0.4 0.4 17 5 14 305 8 0 8 0 -7.1 0 -6.9 -7.3 04/22/2005 04:30:00 17.3 1.6 21 13 17.1 1.5 21.4 13 0.4 0 0.4 0.4 15 5 13 305 8 0 8 0 -7 0 -6.7 -7.3 04/22/2005 04:40:00 17.3 1.7 21.4 13 16.9 1.8 21.4 12.2 0.4 0 0.4 0.4 15 5 23 305 8 0 8 0 -7 0 -6.7 -7.1 04/22/2005 04:50:00 16.6 1.8 21 12.2 16.4 1.9 20.2 11.8 0.4 0 0.4 0.4 16 5 18 305 8 0 8 0 -6.9 0 -6.7 -7.1 04/22/2005 05:00:00 15.9 1.8 20.6 11.8 15.6 1.7 19.5 11.1 0.4 0 0.4 0.4 13 5 7 305 9 0 9 0 -6.9 0 -6.7 -7.1 04/22/2005 05:10:00 16 1.8 20.6 12.2 15.8 1.8 19.9 11.8 0.4 0 0.4 0.4 12 5 9 305 9 0 9 0 -7 0 -6.9 -7.1 04/22/2005 05:20:00 16.5 1.7 20.6 10.7 16 1.8 19.9 11.1 0.4 0 0.4 0.4 12 5 11 305 9 0 9 0 -7.1 0 -6.9 -7.1 04/22/2005 05:30:00 15.7 1.7 19.9 11.5 15.5 1.5 19.1 11.5 0.4 0 0.4 0.4 12 5 17 305 9 0 9 0 -7 0 -6.9 -7.1 04/22/2005 05:40:00 16.6 1.5 20.2 11.8 16.3 1.5 19.5 12.2 0.4 0 0.4 0.4 12 5 11 305 9 0 9 0 -7 0 -6.9 -7.1 04/22/2005 05:50:00 16.9 1.7 21 12.6 16.7 1.7 21 12.2 0.4 0 0.4 0.4 13 5 11 305 10 0 9 0 -6.9 0 -6.9 -7.1 04/22/2005 06:00:00 17.1 1.8 21 12.2 16.7 1.7 20.6 12.2 0.4 0 0.4 0.4 12 5 12 305 10 0 10 0 -6.8 0 -6.7 -6.9 04/22/2005 06:10:00 16.1 2.1 21.8 11.1 15.8 2.1 22.1 11.1 0.4 0 0.4 0.4 12 5 8 305 10 0 10 0 -6.7 0 -6.4 -6.9 04/22/2005 06:20:00 17 1.9 22.6 12.2 16.7 1.9 22.6 11.5 0.4 0 0.4 0.4 12 5 16 305 10 0 11 0 -6.6 0 -6.4 -6.9 04/22/2005 06:30:00 16.6 1.9 21 11.5 16.3 1.9 20.6 12.6 0.4 0 0.4 0.4 13 5 14 305 11 0 11 0 -6.7 0 -6.7 -6.9 04/22/2005 06:40:00 16.4 1.7 19.9 12.2 16.1 1.7 19.9 11.1 0.4 0 0.4 0.4 12 5 14 305 11 0 11 0 -6.6 0 -6.4 -6.9 04/22/2005 06:50:00 17 1.5 20.6 13.7 16.6 1.4 20.2 13 0.4 0 0.4 0.4 12 5 14 305 11 0 11 0 -6.6 0 -6.4 -6.9 04/22/2005 07:00:00 17.3 1.8 21 13 17.1 1.8 21 13 0.4 0 0.4 0.4 11 5 9 305 11 0 11 0 -6.5 0 -6.2 -6.7 04/22/2005 07:10:00 17.3 1.5 21.4 13 17 1.6 21.4 13 0.4 0 0.4 0.4 11 4 8 305 11 0 11 0 -6.4 0 -6.2 -6.7 04/22/2005 07:20:00 16.8 1.5 19.9 12.2 16.4 1.4 19.9 12.6 0.4 0 0.4 0.4 9 5 5 305 12 0 12 0 -6.4 0 -6.2 -6.7 04/22/2005 07:30:00 15.6 1.9 19.5 10.7 15.3 1.8 19.5 11.5 0.4 0 0.4 0.4 12 5 15 305 12 0 12 0 -6.3 0 -6 -6.4 04/22/2005 07:40:00 15.5 1.5 19.1 11.8 15.2 1.4 18.7 12.2 0.4 0 0.4 0.4 9 5 4 305 12 0 12 0 -6.3 0 -6 -6.4 04/22/2005 07:50:00 14.6 1.8 18.3 9.5 14.5 1.8 19.1 9.9 0.4 0 0.4 0.4 10 6 8 305 13 0 13 0 -6.3 0 -6 -6.4 04/22/2005 08:00:00 14.7 1.6 18.3 10.3 14.7 1.5 18.7 11.1 0.4 0 0.4 0.4 5 5 5 305 13 0 12 0 -6.8 0.2 -6.4 -7.1 04/22/2005 08:10:00 15.4 1.3 19.1 10.3 15.2 1.4 18.3 10.3 0.4 0 0.4 0.4 5 5 355 305 12 0 12 0 -7 0 -6.9 -7.1 04/22/2005 08:20:00 14.2 1.6 17.9 10.3 14 1.5 18.3 10.3 0.4 0 0.4 0.4 5 5 7 305 13 0 13 0 -7 0 -6.7 -7.1 04/22/2005 08:30:00 13.7 1.5 17.2 9.9 13.6 1.5 17.6 9.5 0.4 0 0.4 0.4 5 6 358 305 13 0 13 0 -6.9 0 -6.7 -7.1 04/22/2005 08:40:00 13.4 1.3 17.2 10.3 13.3 1.4 16.8 9.5 0.4 0 0.4 0.4 1 5 3 305 13 0 13 0 -7.1 0 -6.9 -7.3 04/22/2005 08:50:00 13.5 1.5 16.8 9.9 13.3 1.6 17.2 9.9 0.4 0 0.4 0.4 2 5 2 305 13 0 13 0 -7.1 0 -6.9 -7.3 04/22/2005 09:00:00 13 1.5 16.4 10.3 12.9 1.5 16.8 9.9 0.4 0 0.4 0.4 1 5 0 305 13 0 13 0 -7.1 0 -6.9 -7.3 04/22/2005 09:10:00 13.8 1.3 16.4 10.7 13.7 1.3 16.4 10.3 0.4 0 0.4 0.4 1 5 9 305 14 0 14 0 -7 0 -6.7 -7.1 04/22/2005 09:20:00 13.1 1.3 16.4 9.5 13 1.3 16.4 9.9 0.4 0 0.4 0.4 1 5 1 305 14 0 14 0 -6.9 0 -6.7 -7.1 04/22/2005 09:30:00 13.3 1.1 16.1 9.9 13.1 1.1 15.6 9.9 0.4 0 0.4 0.4 1 5 8 305 14 0 14 0 -6.8 0 -6.7 -6.9 04/22/2005 09:40:00 12.4 1.2 15.6 9.5 12.2 1.2 15.6 9.5 0.4 0 0.4 0.4 0 5 350 305 15 0 15 0 -6.7 0 -6.7 -6.9 04/22/2005 09:50:00 12.6 1.3 15.6 9.5 12.4 1.3 16.4 9.1 0.4 0 0.4 0.4 0 5 1 305 15 0 15 0 -6.6 0 -6.4 -6.9 04/22/2005 10:00:00 12.5 1.3 15.3 9.1 12.3 1.3 16.1 8.8 0.4 0 0.4 0.4 359 5 355 305 16 0 16 0 -6.4 0 -6.2 -6.7 04/22/2005 10:10:00 12.3 1 14.5 9.1 12.3 1 15.3 9.1 0.4 0 0.4 0.4 356 5 350 305 16 0 16 0 -6.5 0 -6.2 -6.7 04/22/2005 10:20:00 12.8 1.4 15.6 9.1 12.7 1.4 15.3 9.1 0.4 0 0.4 0.4 354 5 352 305 17 0 16 0 -6.5 0 -6.2 -6.7 04/22/2005 10:30:00 12 1.4 15.3 8 12 1.4 15.3 7.6 0.4 0 0.4 0.4 359 5 359 305 17 0 17 0 -6.4 0 -6.2 -6.7 04/22/2005 10:40:00 13 1.1 15.3 9.9 13 1 15.6 10.3 0.4 0 0.4 0.4 356 4 351 305 18 0 18 0 -6.4 0 -6.2 -6.7 04/22/2005 10:50:00 12.5 1.3 15.3 9.1 12.5 1.3 16.1 9.5 0.4 0 0.4 0.4 355 5 352 305 18 0 18 0 -6.4 0 -6.2 -6.7 04/22/2005 11:00:00 12.7 1 14.9 9.5 12.7 1 14.9 9.1 0.4 0 0.4 0.4 353 4 355 305 19 0 19 0 -6.4 0 -6.2 -6.7 04/22/2005 11:10:00 12.4 1 14.9 9.5 12.3 1 14.5 9.5 0.4 0 0.4 0.4 353 4 357 305 19 0 19 0 -6.4 0 -6.2 -6.7 04/22/2005 11:20:00 12.4 1.1 14.5 9.1 12.3 1.2 14.5 9.5 0.4 0 0.4 0.4 352 4 350 305 20 0 20 0 -6.3 0 -6.2 -6.4 04/22/2005 11:30:00 11.9 1.2 14.5 8.4 11.9 1.3 14.5 8 0.4 0 0.4 0.4 351 4 344 305 20 0 20 0 -6.3 0 -6 -6.4 04/22/2005 11:40:00 11.8 1 14.5 8.8 11.9 1 14.5 8.8 0.4 0 0.4 0.4 351 4 354 305 21 0 21 0 -6.2 0 -6 -6.4 04/22/2005 11:50:00 11.7 1.1 14.1 8.8 11.8 1.1 14.5 8.8 0.4 0 0.4 0.4 353 5 348 305 22 0 22 0 -6.1 0 -6 -6.2 04/22/2005 12:00:00 11.2 1 13.3 8.8 11.3 1 13.7 8.8 0.4 0 0.4 0.4 352 5 353 305 23 0 24 0 -6 0 -5.8 -6.2 04/22/2005 12:10:00 10.9 1 13.3 8.4 10.9 1 13 8 0.4 0 0.4 0.4 350 5 347 305 24 0 24 0 -5.9 0 -5.8 -6 04/22/2005 12:20:00 10.7 1 13 8.4 10.7 1 13.3 8.4 0.4 0 0.4 0.4 351 5 347 305 26 0 25 0 -5.8 0 -5.6 -6 04/22/2005 12:30:00 10.6 1 13 8 10.7 1 13 8.4 0.4 0 0.4 0.4 351 5 354 305 27 0 26 0 -5.8 0 -5.6 -6 04/22/2005 12:40:00 9.9 1 12.2 7.6 10 1 12.2 7.6 0.4 0 0.4 0.4 350 5 353 305 28 0 28 0 -5.7 0 -5.6 -5.8 04/22/2005 12:50:00 9.9 1 12.6 7.2 10.1 1 12.2 7.2 0.4 0 0.4 0.4 349 5 340 305 29 0 28 0 -5.6 0 -5.6 -5.8 04/22/2005 13:00:00 9.6 1 11.5 7.2 9.7 1.1 12.2 6.8 0.4 0 0.4 0.4 351 5 353 305 29 0 29 0 -5.6 0 -5.6 -5.8 04/22/2005 13:10:00 9.6 0.8 11.5 7.2 9.7 0.9 11.8 7.2 0.4 0 0.4 0.4 350 4 349 305 29 0 29 0 -5.6 0 -5.6 -5.8 04/22/2005 13:20:00 9.3 0.8 11.1 6.8 9.4 0.8 11.1 6.8 0.4 0 0.4 0.4 351 4 347 305 29 0 29 0 -5.5 0 -5.6 -5.6 04/22/2005 13:30:00 8.5 1.1 11.1 5.7 8.5 1.1 11.1 5.7 0.4 0 0.4 0.4 351 5 352 305 30 0 29 0 -5.4 0 -5.1 -5.6 04/22/2005 13:40:00 9.2 0.8 10.7 7.2 9.2 0.8 11.1 6.8 0.4 0 0.4 0.4 350 5 351 305 30 0 30 0 -5.3 0 -5.1 -5.6 04/22/2005 13:50:00 8.8 0.7 10.7 6.8 8.9 0.8 10.7 6.8 0.4 0 0.4 0.4 353 4 353 305 31 0 31 0 -5.3 0 -5.1 -5.6 04/22/2005 14:00:00 8.2 0.6 10.3 6.8 8.4 0.7 10.3 6.5 0.4 0 0.4 0.4 355 3 353 305 32 0 32 0 -5.2 0 -4.7 -5.6 04/22/2005 14:10:00 7.7 0.7 9.1 6.1 7.8 0.7 9.1 6.1 0.4 0 0.4 0.4 356 4 351 305 33 0 33 0 -5.2 0.1 -4.9 -5.6 04/22/2005 14:20:00 7.2 0.6 8.4 5.3 7.2 0.7 8.8 5.3 0.4 0 0.4 0.4 354 6 359 305 35 0 35 0 -5.1 0 -4.5 -5.3 04/22/2005 14:30:00 7.1 1 9.1 5.3 7.1 1 9.5 4.9 0.4 0 0.4 0.4 351 7 350 305 37 1 38 0 -4.9 0 -4.5 -5.1 04/22/2005 14:40:00 7.9 1 9.9 5.3 8 0.9 9.9 5.3 0.4 0 0.4 0.4 354 5 355 305 38 0 38 0 -4.9 0 -4.2 -5.1 04/22/2005 14:50:00 7.3 0.7 8.8 5.7 7.4 0.7 8.8 5.3 0.4 0 0.4 0.4 355 5 357 305 40 1 39 0 -4.7 0 -4 -4.9 04/22/2005 15:00:00 7 0.8 8.4 4.9 7.1 0.8 8.8 4.6 0.4 0 0.4 0.4 354 4 353 305 42 1 42 0 -4.6 0 -4 -4.9 04/22/2005 15:10:00 6.4 0.7 8 4.9 6.4 0.8 8 4.6 0.4 0 0.4 0.4 358 5 358 305 44 1 43 0 -4.6 0 -4.5 -4.7 04/22/2005 15:20:00 6.6 0.6 7.6 4.9 6.6 0.6 8 4.6 0.4 0 0.4 0.4 356 4 1 305 48 1 48 0 -4.6 0 -4.5 -4.7 04/22/2005 15:30:00 6.2 0.6 7.6 4.6 6.3 0.6 7.6 4.9 0.4 0 0.4 0.4 353 3 356 305 51 1 49 0 -4.5 0 -4.5 -4.7 04/22/2005 15:40:00 5 0.6 6.1 3.4 5.1 0.6 6.5 3.8 0.4 0 0.4 0.4 351 4 347 305 54 1 53 0 -4.4 0 -4 -4.5 04/22/2005 15:50:00 4.4 0.5 5.7 3 4.5 0.6 5.7 3 0.4 0 0.4 0.4 355 6 343 305 57 1 56 0 -4.3 0.1 -4 -4.5 04/22/2005 16:00:00 4 0.5 4.9 2.6 4.1 0.5 5.3 3 0.4 0 0.4 0.4 1 5 1 305 60 1 60 0 -4.3 0.1 -3.8 -4.5 04/22/2005 16:10:00 4.2 0.4 4.9 3 4.2 0.4 4.9 3 0.4 0 0.4 0.4 7 4 4 305 67 4 62 0 -4.2 0 -4 -4.5 04/22/2005 16:20:00 3.6 0.3 4.2 2.6 3.5 0.3 4.6 2.6 0.4 0 0.4 0.4 6 5 13 305 72 1 72 0 -4.1 0 -4 -4.2 04/22/2005 16:30:00 2.8 0.5 4.2 1.9 2.8 0.5 4.2 1.9 0.4 0 0.4 0.4 22 9 10 305 89 15 74 0 -3.9 0 -3.8 -4 04/22/2005 16:40:00 3 0.5 4.2 2.3 3 0.6 4.6 2.3 0.4 0 0.4 0.4 49 7 51 305 99 11 90 0 -3.7 0 -3.1 -3.8 04/22/2005 16:50:00 3.7 0.2 4.2 3 3.7 0.3 4.2 3 0.4 0 0.4 0.4 50 4 48 305 90 1 89 0 -4 0 -3.3 -4 04/22/2005 17:00:00 4.4 0.4 4.9 3.4 4.3 0.4 4.9 3 0.4 0 0.4 0.4 60 4 58 305 94 2 92 0 -3.9 0 -3.3 -4 04/22/2005 17:10:00 4.3 0.3 4.9 3.4 4.3 0.3 4.9 3.4 0.4 0 0.4 0.4 61 3 62 305 98 1 98 0 -4.1 0.2 -3.3 -4.5 04/22/2005 17:20:00 3.9 0.4 4.9 2.6 3.9 0.4 4.9 2.3 0.4 0 0.4 0.4 59 9 59 305 97 1 96 0 -4.6 0 -3.8 -4.7 04/22/2005 17:30:00 3 1 4.9 0.4 2.9 0.9 4.6 0.4 0.4 0 0.4 0.4 99 28 118 305 98 6 100 0 -4 0.5 -3.1 -4.7 04/22/2005 17:40:00 3 0.8 4.6 0.4 3.3 0.6 4.6 1.9 0.4 0 0.4 0.4 116 14 116 305 79 3 86 0 -3 0.1 -2.7 -3.3 04/22/2005 17:50:00 3.2 0.7 4.6 1.5 3.5 0.7 4.9 1.1 0.4 0 0.4 0.4 113 12 106 305 75 0 75 0 -2.8 0 -2.4 -3.1 04/22/2005 18:00:00 3.1 0.8 4.9 1.5 3.5 0.8 4.9 1.1 0.4 0 0.4 0.4 117 15 123 305 75 0 75 0 -2.9 0 -2.7 -3.1 04/22/2005 18:10:00 3.7 0.9 5.3 1.1 4 0.7 5.7 1.9 0.4 0 0.4 0.4 112 9 114 305 75 0 75 0 -2.8 0 -2.7 -2.9 04/22/2005 18:20:00 3.7 0.8 5.3 1.1 4 0.6 5.3 1.9 0.4 0 0.4 0.4 120 13 122 305 75 0 75 0 -2.7 0 -2 -3.1 04/22/2005 18:30:00 3.3 0.9 5.3 0.7 3.4 0.9 5.3 1.1 0.4 0 0.4 0.4 131 16 112 305 76 1 77 0 -2.2 0.1 -2 -2.7 04/22/2005 18:40:00 4.6 0.6 5.7 3 4.7 0.5 5.7 3.4 0.4 0 0.4 0.4 120 8 118 305 75 0 75 0 -2.9 0.3 -2.2 -3.6 04/22/2005 18:50:00 5.3 0.7 6.8 3.4 5.4 0.6 6.5 3.4 0.4 0 0.4 0.4 117 8 116 305 74 0 75 0 -3.9 0.2 -3.3 -4.5 04/22/2005 19:00:00 6.1 0.7 7.6 3.8 6.2 0.6 8 3.8 0.4 0 0.4 0.4 115 5 113 305 74 0 74 0 -4.6 0.2 -4.2 -4.9 04/22/2005 19:10:00 5.8 0.5 7.2 4.2 5.8 0.5 6.8 4.6 0.4 0 0.4 0.4 125 8 105 305 74 0 74 0 -5 0 -4.7 -5.1 04/22/2005 19:20:00 5.7 0.7 7.2 3.8 5.8 0.7 7.2 4.2 0.4 0 0.4 0.4 127 7 132 305 74 0 74 0 -5.1 0 -4.7 -5.3 04/22/2005 19:30:00 6.1 0.5 6.8 4.6 6.1 0.5 6.8 4.6 0.4 0 0.4 0.4 131 6 132 305 74 0 74 0 -5.3 0 -5.1 -5.6 04/22/2005 19:40:00 6.2 0.6 7.2 4.2 6.2 0.5 7.2 4.6 0.4 0 0.4 0.4 126 8 131 305 73 0 73 0 -5.5 0 -5.1 -5.6 04/22/2005 19:50:00 6.2 0.6 8 4.6 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 114 7 103 305 74 0 74 0 -5.5 0 -5.1 -5.6 04/22/2005 20:00:00 5.7 0.6 7.6 3.8 5.7 0.6 7.6 4.2 0.4 0 0.4 0.4 127 8 134 305 75 0 76 0 -5.5 0 -5.3 -5.6 04/22/2005 20:10:00 5.8 0.5 6.8 4.2 5.9 0.5 6.8 4.2 0.4 0 0.4 0.4 128 5 114 305 76 0 76 0 -5.4 0 -5.3 -5.6 04/22/2005 20:20:00 5.8 0.6 7.2 3.8 5.7 0.7 7.2 4.2 0.4 0 0.4 0.4 125 6 133 305 77 0 77 0 -5.5 0 -5.3 -5.6 04/22/2005 20:30:00 5.9 0.6 7.2 3.4 5.9 0.5 7.2 4.2 0.4 0 0.4 0.4 130 6 134 305 77 0 78 0 -5.5 0 -5.3 -5.6 04/22/2005 20:40:00 5.8 0.6 7.2 3.4 5.9 0.6 7.2 4.2 0.4 0 0.4 0.4 135 9 134 305 78 0 78 0 -5.3 0 -5.1 -5.6 04/22/2005 20:50:00 5 0.5 6.5 3.4 5 0.5 6.1 3.4 0.4 0 0.4 0.4 142 7 146 305 79 0 79 0 -5.5 0 -5.3 -5.6 04/22/2005 21:00:00 4.5 0.7 6.1 2.6 4.7 0.7 6.8 3 0.4 0 0.4 0.4 149 15 137 305 80 0 80 0 -5.3 0 -5.1 -5.6 04/22/2005 21:10:00 5.4 0.8 7.2 2.6 5.4 0.7 7.2 3.4 0.4 0 0.4 0.4 206 14 219 305 82 1 82 0 -4.5 0.2 -4 -5.1 04/22/2005 21:20:00 6.3 0.5 7.6 4.9 5.9 0.6 7.2 3.8 0.4 0 0.4 0.4 222 4 221 305 83 0 83 0 -4.2 0 -4 -4.5 04/22/2005 21:30:00 6.5 0.6 8 4.9 5.8 0.7 7.6 4.2 0.4 0 0.4 0.4 224 4 225 305 83 0 84 0 -4.4 0 -4.2 -4.5 04/22/2005 21:40:00 6 0.4 7.2 4.9 5.6 0.4 6.5 4.2 0.4 0 0.4 0.4 221 4 223 305 84 0 84 0 -4.4 0 -4.2 -4.5 04/22/2005 21:50:00 6.8 1 9.1 4.9 6.2 1 9.9 4.2 0.4 0 0.4 0.4 236 14 254 305 84 0 84 0 -4.3 0 -4 -4.5 04/22/2005 22:00:00 8 0.7 9.5 5.7 7.3 0.9 9.1 4.6 0.4 0 0.4 0.4 246 5 247 305 84 0 84 0 -4.4 0 -4.2 -4.7 04/22/2005 22:10:00 7.5 0.8 9.1 5.3 6.8 0.9 8.8 4.9 0.4 0 0.4 0.4 248 5 251 305 83 0 82 0 -4.6 0 -4.5 -4.7 04/22/2005 22:20:00 7.5 0.6 9.1 6.1 6.9 0.8 9.1 4.6 0.4 0 0.4 0.4 249 5 250 305 82 0 82 0 -4.8 0 -4.7 -4.9 04/22/2005 22:30:00 7.4 0.7 9.1 5.3 6.6 0.8 8.4 4.6 0.4 0 0.4 0.4 246 5 250 305 81 0 82 0 -4.9 0 -4.7 -5.1 04/22/2005 22:40:00 6.9 0.6 8.4 5.3 6 0.7 7.6 4.2 0.4 0 0.4 0.4 247 5 236 305 82 0 82 0 -5 0 -4.9 -5.1 04/22/2005 22:50:00 7.5 0.6 9.1 5.7 6.7 0.8 8.4 4.2 0.4 0 0.4 0.4 247 5 246 305 82 0 82 0 -5 0 -4.9 -5.1 04/22/2005 23:00:00 7.4 0.6 9.5 5.7 6.6 0.8 9.1 4.2 0.4 0 0.4 0.4 248 5 250 305 83 0 83 0 -5 0 -4.9 -5.1 04/22/2005 23:10:00 7.6 0.5 9.1 5.7 6.8 0.7 8.4 4.6 0.4 0 0.4 0.4 242 5 237 305 83 0 83 0 -5.1 0 -4.9 -5.1 04/22/2005 23:20:00 7.4 0.6 8.8 5.7 6.7 0.8 8.8 4.6 0.4 0 0.4 0.4 247 4 250 305 83 0 83 0 -5.1 0 -4.9 -5.3 04/22/2005 23:30:00 6.8 0.6 8.4 5.3 6.1 0.7 8 4.2 0.4 0 0.4 0.4 247 6 248 305 83 0 84 0 -5.1 0 -4.9 -5.1 04/22/2005 23:40:00 6.7 0.6 8 4.9 5.9 0.8 7.6 3.8 0.4 0 0.4 0.4 248 5 246 305 84 0 84 0 -5.1 0 -4.9 -5.1 04/22/2005 23:50:00 6.9 0.6 8.4 5.3 6 0.7 7.6 4.2 0.4 0 0.4 0.4 246 5 249 305 84 0 84 0 -5 0 -4.9 -5.1 04/23/2005 00:00:00 7.1 0.6 8.4 5.3 6.4 0.7 8.4 4.2 0.4 0 0.4 0.4 249 5 252 305 84 0 84 0 -5 0 -4.7 -5.1 04/23/2005 00:10:00 6.8 0.7 8.8 5.3 6 0.9 8 3.4 0.4 0 0.4 0.4 249 6 261 305 83 0 84 0 -5 0 -4.9 -5.1 04/23/2005 00:20:00 6.6 0.5 8 4.6 5.9 0.6 7.2 3.8 0.4 0 0.4 0.4 244 4 242 305 82 0 82 0 -5.1 0 -4.9 -5.3 04/23/2005 00:30:00 6.8 0.5 8 5.3 6.1 0.6 7.6 4.2 0.4 0 0.4 0.4 244 5 250 305 82 0 82 0 -5.1 0 -5.1 -5.3 04/23/2005 00:40:00 6.6 0.6 7.6 4.9 5.8 0.7 7.6 4.2 0.4 0 0.4 0.4 243 5 250 305 82 0 82 0 -5.2 0 -4.9 -5.3 04/23/2005 00:50:00 6.6 0.8 8.4 4.6 5.9 0.8 8 4.2 0.4 0 0.4 0.4 242 4 237 305 82 0 82 0 -5.2 0 -5.1 -5.3 04/23/2005 01:00:00 6.3 0.7 7.6 4.6 5.6 0.7 7.2 3.8 0.4 0 0.4 0.4 244 4 244 305 82 0 82 0 -5.2 0 -5.1 -5.3 04/23/2005 01:10:00 6.5 0.5 8 4.9 5.7 0.6 7.6 4.2 0.4 0 0.4 0.4 243 5 248 305 83 0 83 0 -5.1 0 -4.9 -5.3 04/23/2005 01:20:00 6.3 0.7 8.4 4.2 5.6 0.8 7.6 3.8 0.4 0 0.4 0.4 242 5 236 305 83 0 83 0 -5.1 0 -4.9 -5.3 04/23/2005 01:30:00 6.5 0.9 8.4 4.2 5.8 0.9 7.6 3.8 0.4 0 0.4 0.4 238 5 238 305 83 0 84 0 -5 0 -4.9 -5.1 04/23/2005 01:40:00 6.6 0.7 8.4 4.9 6 0.8 7.6 4.2 0.4 0 0.4 0.4 235 4 242 305 84 0 84 0 -5 0 -4.9 -5.1 04/23/2005 01:50:00 7.4 0.6 8.8 5.7 6.7 0.7 8.4 4.9 0.4 0 0.4 0.4 236 6 238 305 83 0 84 0 -5.1 0 -4.9 -5.1 04/23/2005 02:00:00 7.4 0.5 8.4 5.7 6.7 0.6 8.4 4.9 0.4 0 0.4 0.4 230 3 234 305 83 0 83 0 -5.1 0 -4.9 -5.1 04/23/2005 02:10:00 7.4 0.6 8.8 6.1 6.7 0.7 8.4 4.9 0.4 0 0.4 0.4 235 4 232 305 83 0 84 0 -5 0 -4.9 -5.1 04/23/2005 02:20:00 7.4 0.6 9.1 5.7 6.7 0.8 8.4 4.2 0.4 0 0.4 0.4 239 4 239 305 83 0 83 0 -5.1 0 -4.9 -5.1 04/23/2005 02:30:00 8.2 0.8 10.3 6.1 7.6 1 9.9 5.3 0.4 0 0.4 0.4 239 6 236 305 84 0 84 0 -5 0 -4.9 -5.1 04/23/2005 02:40:00 8.4 1 10.3 5.7 7.9 1 9.9 5.3 0.4 0 0.4 0.4 235 4 238 305 84 0 84 0 -5 0 -4.9 -5.1 04/23/2005 02:50:00 8.5 0.8 11.1 6.1 7.9 0.8 10.3 5.7 0.4 0 0.4 0.4 235 5 238 305 84 0 84 0 -5.1 0 -4.9 -5.1 04/23/2005 03:00:00 8.7 1 10.7 6.5 8 1 10.3 5.7 0.4 0 0.4 0.4 239 5 240 305 84 0 85 0 -5.1 0 -4.9 -5.3 04/23/2005 03:10:00 7.8 0.6 9.9 6.1 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 237 5 232 305 84 0 85 0 -5.2 0 -4.9 -5.3 04/23/2005 03:20:00 9.1 0.9 11.8 6.5 8.4 1 11.1 5.7 0.4 0 0.4 0.4 237 5 232 305 85 0 85 0 -5.1 0 -4.9 -5.3 04/23/2005 03:30:00 9.2 1 11.5 7.2 8.6 1 10.7 6.5 0.4 0 0.4 0.4 240 5 234 305 86 0 86 0 -5 0 -4.9 -5.1 04/23/2005 03:40:00 9.9 1.1 12.6 6.5 9.1 1 11.1 6.5 0.4 0 0.4 0.4 243 5 241 305 87 0 86 0 -5 0 -4.7 -5.1 04/23/2005 03:50:00 9.7 0.9 11.8 6.8 9 1.1 11.8 5.7 0.4 0 0.4 0.4 247 5 242 305 87 0 87 0 -4.9 0 -4.7 -4.9 04/23/2005 04:00:00 9.5 1 12.2 6.8 8.7 1 11.1 5.7 0.4 0 0.4 0.4 244 6 239 305 87 0 87 0 -4.9 0 -4.7 -5.1 04/23/2005 04:10:00 9.4 1 11.5 6.5 8.5 1.1 11.1 4.9 0.4 0 0.4 0.4 252 6 259 305 87 0 88 0 -4.9 0 -4.7 -5.1 04/23/2005 04:20:00 9.4 1 11.8 6.5 8.4 1 11.1 5.7 0.4 0 0.4 0.4 254 6 256 305 87 0 87 0 -4.9 0 -4.7 -5.1 04/23/2005 04:30:00 9.4 0.9 11.5 6.5 7.9 1 11.1 5.7 0.4 0 0.4 0.4 257 6 259 305 87 0 87 0 -5 0 -4.7 -5.1 04/23/2005 04:40:00 9.4 1 11.5 6.1 7.8 1.1 10.7 4.9 0.4 0 0.4 0.4 259 5 258 305 87 0 87 0 -5 0 -4.9 -5.1 04/23/2005 04:50:00 9.1 0.9 11.1 6.1 7.3 1 9.5 4.2 0.4 0 0.4 0.4 261 5 263 305 86 0 86 0 -5 0 -4.9 -5.1 04/23/2005 05:00:00 8.5 1.2 11.1 5.3 6.9 1.2 11.1 4.2 0.4 0 0.4 0.4 260 6 251 305 87 0 87 0 -5 0 -4.9 -5.1 04/23/2005 05:10:00 8.2 0.9 10.3 5.3 6.9 1.1 9.9 4.6 0.4 0 0.4 0.4 257 6 253 305 87 0 87 0 -5 0 -4.9 -5.1 04/23/2005 05:20:00 9 1 11.1 6.1 8.1 1 10.7 5.3 0.4 0 0.4 0.4 250 6 251 305 87 0 86 0 -5.2 0 -4.9 -5.3 04/23/2005 05:30:00 8.3 0.9 11.1 5.7 7.2 1.2 9.9 4.2 0.4 0 0.4 0.4 254 7 244 305 87 0 87 0 -5.2 0 -5.1 -5.3 04/23/2005 05:40:00 8.9 0.9 11.1 6.5 7.9 1.1 10.7 5.7 0.4 0 0.4 0.4 253 6 244 305 87 0 87 0 -5.2 0 -5.1 -5.3 04/23/2005 05:50:00 9.6 0.9 11.8 6.5 8.8 1.2 11.1 5.7 0.4 0 0.4 0.4 250 5 246 305 88 0 88 0 -5.3 0 -5.1 -5.6 04/23/2005 06:00:00 9.8 0.9 11.8 6.8 9 1.1 11.5 5.7 0.4 0 0.4 0.4 249 5 246 305 86 0 87 0 -5.6 0 -5.3 -5.8 04/23/2005 06:10:00 8.4 0.6 9.9 6.1 7.5 0.9 9.5 5.7 0.4 0 0.4 0.4 253 6 247 305 85 0 86 0 -5.7 0 -5.6 -5.8 04/23/2005 06:20:00 7.6 1 10.3 5.3 6.5 1.1 9.5 3.4 0.4 0 0.4 0.4 256 6 261 305 85 0 85 0 -5.7 0 -5.6 -5.8 04/23/2005 06:30:00 7.3 1 9.9 4.2 6 1 8.4 3.4 0.4 0 0.4 0.4 259 7 259 305 85 0 85 0 -5.7 0 -5.6 -5.8 04/23/2005 06:40:00 7.6 1.1 9.5 4.9 7 1.1 9.1 4.2 0.4 0 0.4 0.4 248 5 246 305 85 0 85 0 -5.7 0 -5.6 -5.8 04/23/2005 06:50:00 8.1 0.9 10.3 5.7 7.1 1 9.9 4.2 0.4 0 0.4 0.4 251 6 252 305 85 0 85 0 -5.8 0 -5.6 -5.8 04/23/2005 07:00:00 7.8 0.7 9.9 5.7 6.7 0.9 10.7 4.6 0.4 0 0.4 0.4 257 8 251 305 84 0 84 0 -5.8 0 -5.8 -6 04/23/2005 07:10:00 7.6 0.8 9.5 5.7 6.3 0.9 8.8 3.8 0.4 0 0.4 0.4 259 6 260 305 84 0 84 0 -5.8 0 -5.6 -6 04/23/2005 07:20:00 7.9 0.8 9.5 4.6 6.9 1 9.1 4.2 0.4 0 0.4 0.4 255 6 256 305 84 0 84 0 -5.8 0 -5.6 -6 04/23/2005 07:30:00 7.3 1 9.5 4.6 6.4 1.2 8.8 2.6 0.4 0 0.4 0.4 255 5 247 305 83 0 83 0 -6 0 -5.8 -6 04/23/2005 07:40:00 7.3 0.9 9.5 4.9 6.6 1.1 9.1 3.8 0.4 0 0.4 0.4 249 6 255 305 83 0 83 0 -5.9 0 -5.8 -6 04/23/2005 07:50:00 7.4 0.8 8.8 5.3 6.5 1 9.1 4.2 0.4 0 0.4 0.4 248 6 245 305 83 0 83 0 -5.9 0 -5.8 -6 04/23/2005 08:00:00 7.3 0.8 9.1 4.9 6.5 0.9 8.8 3.8 0.4 0 0.4 0.4 252 5 256 305 83 0 83 0 -5.9 0 -5.8 -6 04/23/2005 08:10:00 7.6 0.7 9.1 5.3 6.6 1 8.8 4.2 0.4 0 0.4 0.4 256 4 252 305 83 0 83 0 -5.9 0 -5.8 -6 04/23/2005 08:20:00 6.8 0.8 8.8 4.6 6.1 1 8 3.4 0.4 0 0.4 0.4 246 8 238 305 83 0 83 0 -5.9 0 -5.8 -6 04/23/2005 08:30:00 7.4 0.6 9.1 5.7 6.7 0.7 8.4 4.6 0.4 0 0.4 0.4 238 4 240 305 83 0 83 0 -6 0 -5.8 -6.2 04/23/2005 08:40:00 6.9 0.8 8.8 4.9 6.3 0.8 8 4.2 0.4 0 0.4 0.4 242 5 237 305 83 0 83 0 -6 0 -5.8 -6.2 04/23/2005 08:50:00 7 0.7 8.8 5.3 6.5 0.8 8.4 4.6 0.4 0 0.4 0.4 240 5 241 305 83 0 84 0 -5.9 0 -5.8 -6 04/23/2005 09:00:00 7.2 0.5 8.8 5.7 6.6 0.6 8 4.9 0.4 0 0.4 0.4 236 5 234 305 83 0 84 0 -6 0 -5.8 -6.2 04/23/2005 09:10:00 7.1 0.7 8.8 4.9 6.5 0.8 8.4 4.2 0.4 0 0.4 0.4 241 4 238 305 82 0 82 0 -6.1 0 -5.8 -6.2 04/23/2005 09:20:00 8.1 0.6 9.5 5.7 7.5 0.8 8.8 4.9 0.4 0 0.4 0.4 233 5 234 305 82 0 82 0 -5.9 0 -5.6 -6 04/23/2005 09:30:00 7.6 0.6 9.1 5.7 7.1 0.6 8.8 5.3 0.4 0 0.4 0.4 231 4 227 305 83 0 83 0 -5.9 0 -5.8 -6 04/23/2005 09:40:00 7.6 0.6 9.1 6.1 6.9 0.8 8.8 4.9 0.4 0 0.4 0.4 234 5 234 305 83 0 83 0 -5.8 0 -5.6 -6 04/23/2005 09:50:00 7.3 0.6 8.8 5.3 6.8 0.6 8.4 4.9 0.4 0 0.4 0.4 236 4 238 305 83 1 82 0 -5.7 0 -5.6 -5.8 04/23/2005 10:00:00 7.4 0.8 8.8 4.9 6.6 0.9 8.8 4.6 0.4 0 0.4 0.4 241 5 244 305 81 1 80 0 -5.8 0 -5.6 -6 04/23/2005 10:10:00 7.5 0.6 8.8 5.7 6.8 0.7 8.4 4.6 0.4 0 0.4 0.4 238 4 233 305 79 0 80 0 -5.7 0 -5.6 -5.8 04/23/2005 10:20:00 7.2 0.7 8.8 4.9 6.6 0.8 8.4 4.6 0.4 0 0.4 0.4 238 4 239 305 79 1 77 0 -5.6 0.1 -5.1 -5.8 04/23/2005 10:30:00 7.5 0.5 8.4 5.7 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 235 6 231 305 81 0 81 0 -5.5 0 -4.9 -5.6 04/23/2005 10:40:00 7.9 0.5 9.1 6.5 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 231 4 231 305 87 2 84 0 -5.3 0 -4.7 -5.6 04/23/2005 10:50:00 7.6 0.5 8.8 6.1 7.2 0.6 8.4 5.3 0.4 0 0.4 0.4 231 4 234 305 92 3 91 0 -5.5 0 -5.1 -5.8 04/23/2005 11:00:00 7.8 0.6 9.1 6.1 7.4 0.7 8.8 5.3 0.4 0 0.4 0.4 228 4 230 305 90 3 86 0 -5.5 0 -5.3 -5.6 04/23/2005 11:10:00 7.3 0.7 8.8 4.9 6.9 0.8 8.4 4.2 0.4 0 0.4 0.4 230 5 235 305 92 1 94 0 -5.4 0 -5.1 -5.6 04/23/2005 11:20:00 7.3 0.6 8.8 5.3 6.8 0.7 8 4.9 0.4 0 0.4 0.4 227 5 224 305 89 4 84 0 -5.3 0 -5.1 -5.6 04/23/2005 11:30:00 7.5 0.5 8.8 5.7 7 0.6 8.4 5.3 0.4 0 0.4 0.4 228 4 231 305 98 2 99 0 -5.5 0 -5.1 -5.6 04/23/2005 11:40:00 7.4 0.7 8.8 5.3 7.1 0.8 8.4 4.9 0.4 0 0.4 0.4 230 4 231 305 100 0 100 0 -5.5 0 -5.1 -5.6 04/23/2005 11:50:00 7.6 0.5 8.8 6.1 7.3 0.6 8.4 5.3 0.4 0 0.4 0.4 232 3 228 305 97 1 98 0 -5.5 0 -5.3 -5.6 04/23/2005 12:00:00 7.3 0.5 8.4 4.9 6.9 0.7 8.4 4.9 0.4 0 0.4 0.4 233 4 232 305 91 6 94 0 -5.4 0 -5.1 -5.6 04/23/2005 12:10:00 7.6 0.8 9.5 5.3 7.2 0.8 8.8 4.9 0.4 0 0.4 0.4 233 4 238 305 75 5 68 0 -5.3 0 -5.1 -5.6 04/23/2005 12:20:00 8.3 0.5 9.5 6.5 7.8 0.6 9.1 5.7 0.4 0 0.4 0.4 234 4 234 305 70 2 67 0 -5.3 0 -5.1 -5.6 04/23/2005 12:30:00 7.8 0.6 9.5 6.1 7.5 0.7 9.1 5.7 0.4 0 0.4 0.4 231 5 237 305 73 0 73 0 -5.3 0 -5.1 -5.6 04/23/2005 12:40:00 7.5 0.8 9.1 5.3 7.1 0.8 8.8 4.9 0.4 0 0.4 0.4 233 6 234 305 69 3 72 0 -5.2 0 -5.1 -5.3 04/23/2005 12:50:00 7.9 0.5 8.8 6.1 7.4 0.6 8.8 5.3 0.4 0 0.4 0.4 235 4 236 305 61 1 60 0 -5.1 0 -4.7 -5.3 04/23/2005 13:00:00 7.4 0.6 8.4 4.9 7.1 0.6 8.4 5.3 0.4 0 0.4 0.4 233 4 225 305 59 1 60 0 -5.1 0 -4.5 -5.3 04/23/2005 13:10:00 6.9 0.6 8 4.6 6.6 0.7 8 4.6 0.4 0 0.4 0.4 230 5 231 305 61 1 61 0 -5 0 -4.5 -5.1 04/23/2005 13:20:00 6.8 0.5 8 4.6 6.5 0.6 7.6 4.6 0.4 0 0.4 0.4 229 5 229 305 69 9 62 0 -4.8 0.1 -4.7 -5.1 04/23/2005 13:30:00 6.5 0.6 8 4.6 6.2 0.7 7.6 4.2 0.4 0 0.4 0.4 228 5 228 305 106 7 108 0 -4.7 0 -4 -4.7 04/23/2005 13:40:00 6.5 0.7 8 4.6 6.1 0.7 7.6 4.6 0.4 0 0.4 0.4 225 5 224 305 107 0 107 0 -4.5 0 -4.5 -4.7 04/23/2005 13:50:00 6.9 0.5 8 5.3 6.6 0.6 7.6 4.9 0.4 0 0.4 0.4 228 4 231 305 107 0 107 0 -4.5 0 -3.8 -4.7 04/23/2005 14:00:00 6.8 0.5 8 5.3 6.5 0.6 8 4.6 0.4 0 0.4 0.4 231 4 224 305 111 1 109 0 -4.5 0 -4 -4.7 04/23/2005 14:10:00 6.5 0.5 7.2 4.9 6.2 0.6 7.2 4.6 0.4 0 0.4 0.4 230 5 229 305 114 1 113 0 -4.4 0 -4 -4.7 04/23/2005 14:20:00 6.5 0.5 7.6 4.9 6.2 0.6 7.6 4.9 0.4 0 0.4 0.4 225 4 225 305 115 0 115 0 -4.3 0 -3.8 -4.5 04/23/2005 14:30:00 6.4 0.7 7.6 4.2 6.2 0.7 7.6 4.6 0.4 0 0.4 0.4 225 4 227 305 113 2 114 0 -4.4 0 -3.8 -4.5 04/23/2005 14:40:00 6.1 0.6 7.6 4.6 5.9 0.6 7.2 4.2 0.4 0 0.4 0.4 223 5 225 305 110 1 111 0 -4.2 0.1 -3.8 -4.5 04/23/2005 14:50:00 6.3 0.6 7.6 4.2 6 0.7 7.2 4.2 0.4 0 0.4 0.4 224 4 227 305 110 1 111 0 -4.3 0.1 -3.8 -4.5 04/23/2005 15:00:00 6.5 0.5 7.6 4.9 6.2 0.6 7.2 4.2 0.4 0 0.4 0.4 222 3 226 305 108 1 107 0 -4.3 0 -3.8 -4.5 04/23/2005 15:10:00 5.9 0.4 7.2 4.6 5.5 0.6 7.2 3.8 0.4 0 0.4 0.4 222 5 228 305 110 0 111 0 -4.1 0 -3.8 -4.2 04/23/2005 15:20:00 5.8 0.5 7.2 4.2 5.6 0.6 7.2 3.8 0.4 0 0.4 0.4 215 7 208 305 110 0 111 0 -4 0 -3.6 -4.2 04/23/2005 15:30:00 6 0.5 7.2 4.2 5.9 0.6 7.2 4.2 0.4 0 0.4 0.4 211 5 208 305 111 1 112 0 -4.1 0 -3.3 -4.2 04/23/2005 15:40:00 5.6 0.6 6.8 4.2 5.5 0.6 6.8 3.8 0.4 0 0.4 0.4 211 6 213 305 108 1 109 0 -4 0 -3.8 -4.2 04/23/2005 15:50:00 6 0.4 6.8 4.9 5.9 0.5 7.2 4.6 0.4 0 0.4 0.4 209 5 208 305 106 1 107 0 -4 0 -3.8 -4.2 04/23/2005 16:00:00 5.8 0.6 6.8 4.2 5.7 0.7 6.8 3.8 0.4 0 0.4 0.4 210 5 208 305 106 1 105 0 -4.1 0 -3.8 -4.2 04/23/2005 16:10:00 5.8 0.4 6.5 4.2 5.7 0.5 6.8 3.8 0.4 0 0.4 0.4 208 5 210 305 106 0 106 0 -4 0 -3.8 -4 04/23/2005 16:20:00 6.3 0.4 7.2 5.3 6.3 0.5 7.2 5.3 0.4 0 0.4 0.4 199 4 205 305 109 1 109 0 -4 0 -3.8 -4 04/23/2005 16:30:00 5.7 0.4 6.5 4.2 5.6 0.5 6.5 4.2 0.4 0 0.4 0.4 194 3 194 305 107 1 108 0 -3.9 0 -3.6 -4 04/23/2005 16:40:00 5.8 0.4 6.8 4.6 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 193 3 195 305 105 1 103 0 -3.9 0 -3.3 -4 04/23/2005 16:50:00 5.6 0.3 6.5 4.9 5.6 0.4 6.5 4.2 0.4 0 0.4 0.4 192 2 196 305 95 3 101 0 -4.4 0.1 -3.8 -4.7 04/23/2005 17:00:00 5.3 0.4 6.1 4.2 5.4 0.5 6.5 3.8 0.4 0 0.4 0.4 191 2 191 305 80 5 78 0 -4.5 0 -4 -4.7 04/23/2005 17:10:00 4.9 0.4 5.7 3.8 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 189 4 181 305 72 2 71 0 -4.2 0.1 -3.8 -4.5 04/23/2005 17:20:00 4.9 0.4 5.7 3.8 5 0.4 5.7 3.8 0.4 0 0.4 0.4 193 4 200 305 65 4 68 0 -4.1 0 -3.6 -4.2 04/23/2005 17:30:00 5 0.4 6.1 3.4 5.1 0.5 6.1 3.4 0.4 0 0.4 0.4 189 4 194 305 40 8 46 0 -3.8 0.1 -3.3 -4 04/23/2005 17:40:00 5.2 0.5 6.5 3.4 5.6 0.4 6.8 4.2 0.4 0 0.4 0.4 186 4 184 305 35 0 35 0 -3.9 0.2 -3.1 -4.2 04/23/2005 17:50:00 5.6 0.4 6.5 4.2 5.9 0.4 6.8 4.6 0.4 0 0.4 0.4 186 3 186 305 34 0 34 0 -3.9 0.1 -3.3 -4.2 04/23/2005 18:00:00 5.2 0.5 6.1 3.8 5.5 0.5 6.5 4.2 0.4 0 0.4 0.4 187 2 191 305 32 0 32 0 -3.9 0.1 -3.1 -4.2 04/23/2005 18:10:00 4.3 0.8 5.7 1.9 5 0.5 6.1 3.8 0.4 0 0.4 0.4 182 5 189 305 31 0 32 0 -3.6 0.1 -2.9 -3.8 04/23/2005 18:20:00 3.2 0.6 4.9 1.9 4.5 0.6 6.1 3.4 0.4 0 0.4 0.4 171 7 164 305 29 0 29 0 -3.1 0.2 -2.4 -3.6 04/23/2005 18:30:00 3.3 0.8 5.3 1.5 3.9 0.6 5.7 2.6 0.4 0 0.4 0.4 159 11 149 305 29 0 29 0 -2.5 0.3 -1.8 -3.1 04/23/2005 18:40:00 4.3 0.6 5.7 2.3 4.4 0.5 5.7 3 0.4 0 0.4 0.4 144 9 149 305 26 1 25 0 -2.2 0 -1.8 -2.4 04/23/2005 18:50:00 5.5 0.4 6.5 4.6 5.4 0.4 6.5 4.2 0.4 0 0.4 0.4 139 4 141 305 24 0 24 0 -2.3 0.1 -1.8 -2.7 04/23/2005 19:00:00 6.2 0.5 7.2 4.6 6.1 0.5 7.6 4.6 0.4 0 0.4 0.4 138 4 137 305 22 1 21 0 -2.8 0 -2.2 -2.9 04/23/2005 19:10:00 7 0.4 8 6.1 6.9 0.4 8 5.7 0.4 0 0.4 0.4 139 3 142 305 19 1 17 0 -2.8 0 -2.4 -3.1 04/23/2005 19:20:00 7.5 0.4 8.4 6.5 7.3 0.3 8 6.5 0.4 0 0.4 0.4 142 3 148 305 15 1 14 0 -3.1 0.1 -2.7 -3.3 04/23/2005 19:30:00 7.9 0.5 9.5 6.8 7.7 0.4 9.1 6.5 0.4 0 0.4 0.4 142 4 154 305 12 1 11 0 -3.5 0.2 -3.3 -4 04/23/2005 19:40:00 8.1 0.9 10.3 6.1 7.8 0.8 10.3 6.1 0.4 0 0.4 0.4 147 6 145 305 11 0 11 0 -3.6 0.2 -3.3 -4 04/23/2005 19:50:00 8.7 0.9 10.7 6.5 8.3 0.8 10.3 6.1 0.4 0 0.4 0.4 148 6 150 305 10 0 10 0 -3.3 0 -3.1 -3.3 04/23/2005 20:00:00 8.8 0.9 11.1 5.7 8.4 0.7 10.3 6.1 0.4 0 0.4 0.4 148 6 151 305 8 0 9 0 -3.5 0 -2.9 -3.8 04/23/2005 20:10:00 8 0.8 10.3 6.1 7.8 0.7 9.9 6.1 0.4 0 0.4 0.4 147 7 143 305 7 0 8 0 -3.7 0 -3.3 -3.8 04/23/2005 20:20:00 7.9 0.9 10.3 5.3 7.7 0.8 10.3 5.7 0.4 0 0.4 0.4 147 6 156 305 7 0 7 0 -3.6 0.1 -3.3 -4 04/23/2005 20:30:00 8 0.8 11.5 6.1 7.8 0.8 10.3 6.1 0.4 0 0.4 0.4 148 7 147 305 6 0 6 0 -4 0.1 -3.8 -4.2 04/23/2005 20:40:00 7.9 0.8 11.1 6.1 7.7 0.7 9.9 5.7 0.4 0 0.4 0.4 146 7 154 305 6 0 6 0 -4.1 0.1 -3.8 -4.2 04/23/2005 20:50:00 8.8 0.8 11.1 5.7 8.5 0.7 10.7 6.8 0.4 0 0.4 0.4 144 7 158 305 7 0 6 0 -3.9 0 -3.8 -4 04/23/2005 21:00:00 8.7 0.8 11.1 6.1 8.4 0.7 10.7 6.1 0.4 0 0.4 0.4 143 5 146 305 6 0 6 0 -4.4 0.2 -3.8 -4.7 04/23/2005 21:10:00 8.6 0.7 10.7 6.8 8.4 0.7 11.1 6.1 0.4 0 0.4 0.4 143 6 133 305 6 0 6 0 -4.9 0 -4.7 -5.1 04/23/2005 21:20:00 8.7 0.5 10.3 7.2 8.4 0.5 9.9 6.8 0.4 0 0.4 0.4 143 4 145 305 6 0 6 0 -5.2 0.1 -4.9 -5.6 04/23/2005 21:30:00 8.8 0.7 11.1 6.8 8.5 0.7 10.7 6.5 0.4 0 0.4 0.4 144 5 155 305 6 0 6 0 -5.3 0 -5.1 -5.6 04/23/2005 21:40:00 8.8 0.6 10.7 7.2 8.5 0.6 10.7 6.8 0.4 0 0.4 0.4 143 5 137 305 7 0 7 0 -5.3 0 -5.1 -5.6 04/23/2005 21:50:00 8.9 0.8 11.1 5.7 8.7 0.7 11.1 6.8 0.4 0 0.4 0.4 144 5 137 305 7 0 8 0 -5.2 0 -4.9 -5.3 04/23/2005 22:00:00 8.5 0.9 11.1 6.5 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 144 6 154 305 9 1 8 0 -5 0 -4.9 -5.1 04/23/2005 22:10:00 9 0.7 11.1 6.8 8.7 0.7 10.7 7.2 0.4 0 0.4 0.4 142 5 147 305 13 1 12 0 -5.2 0.1 -4.9 -5.6 04/23/2005 22:20:00 9.1 0.6 11.1 7.6 8.9 0.6 10.7 7.2 0.4 0 0.4 0.4 142 5 143 305 19 2 20 0 -5.4 0 -5.1 -5.6 04/23/2005 22:30:00 9.5 1 12.6 6.8 9.2 1 11.8 6.8 0.4 0 0.4 0.4 145 6 163 305 27 2 27 0 -5.2 0 -4.9 -5.6 04/23/2005 22:40:00 10.1 0.9 12.6 8 9.9 0.8 12.6 8 0.4 0 0.4 0.4 143 6 136 305 34 2 36 0 -5.4 0.1 -5.1 -5.8 04/23/2005 22:50:00 10 0.9 12.6 7.6 9.7 0.7 12.6 8 0.4 0 0.4 0.4 143 6 134 305 41 2 39 0 -5.8 0 -5.6 -6 04/23/2005 23:00:00 10 0.6 11.5 8.4 9.6 0.5 11.1 8 0.4 0 0.4 0.4 139 4 142 305 46 1 44 0 -6 0 -5.6 -6.2 04/23/2005 23:10:00 10.6 0.5 11.8 8.4 10.3 0.6 11.8 8.8 0.4 0 0.4 0.4 134 3 135 305 51 1 53 0 -5.5 0.2 -5.1 -6 04/23/2005 23:20:00 10.8 0.6 11.8 8.4 10.4 0.6 11.8 8.4 0.4 0 0.4 0.4 136 3 138 305 54 1 55 0 -5.3 0.1 -5.1 -5.6 04/23/2005 23:30:00 10.6 0.7 12.2 8.4 10.3 0.7 12.2 8.8 0.4 0 0.4 0.4 140 4 141 305 56 0 56 0 -5.6 0 -5.3 -5.8 04/23/2005 23:40:00 10.5 0.7 12.2 8.4 10.1 0.7 11.8 8 0.4 0 0.4 0.4 140 4 141 305 58 0 59 0 -5.7 0 -5.6 -5.8 04/23/2005 23:50:00 10.7 0.7 12.6 8.8 10.3 0.7 12.2 8.4 0.4 0 0.4 0.4 142 5 149 305 60 1 61 0 -5.8 0 -5.6 -6 04/24/2005 00:00:00 10.3 1 13 7.6 10 1 12.2 7.2 0.4 0 0.4 0.4 145 7 153 305 63 1 62 0 -5.6 0.1 -5.1 -5.8 04/24/2005 00:10:00 10.2 0.9 12.2 7.6 9.9 0.8 12.2 7.6 0.4 0 0.4 0.4 144 6 147 305 65 1 66 0 -5.8 0.1 -5.6 -6 04/24/2005 00:20:00 10.9 1.2 13.7 8 10.3 1 12.6 8 0.4 0 0.4 0.4 149 6 156 305 67 0 66 0 -5.6 0.1 -5.6 -6 04/24/2005 00:30:00 11.2 1.2 13.7 8.4 10.6 1 13.3 8 0.4 0 0.4 0.4 149 6 152 305 68 0 68 0 -5.6 0 -5.3 -5.8 04/24/2005 00:40:00 10.6 1.1 14.1 8.4 10 1 13.3 8 0.4 0 0.4 0.4 147 6 145 305 69 0 68 0 -5.8 0.1 -5.6 -6.2 04/24/2005 00:50:00 10.2 0.7 13 8 9.7 0.6 11.8 7.6 0.4 0 0.4 0.4 143 5 149 305 69 0 69 0 -6.3 0.2 -5.8 -6.7 04/24/2005 01:00:00 10.1 0.6 11.8 8.4 9.7 0.5 11.5 8 0.4 0 0.4 0.4 144 4 144 305 69 0 69 0 -6.4 0 -6.2 -6.7 04/24/2005 01:10:00 9.9 0.9 13.3 7.6 9.5 0.8 11.8 7.2 0.4 0 0.4 0.4 146 5 144 305 69 0 69 0 -6.2 0 -6 -6.4 04/24/2005 01:20:00 9.5 1 12.6 6.8 9 0.9 11.5 6.8 0.4 0 0.4 0.4 146 6 152 305 70 0 70 0 -6.1 0 -5.8 -6.2 04/24/2005 01:30:00 9.6 0.9 11.8 6.8 9.2 0.8 11.5 7.2 0.4 0 0.4 0.4 144 6 138 305 70 0 70 0 -6.2 0.1 -5.8 -6.4 04/24/2005 01:40:00 10 0.6 11.8 8 9.6 0.7 11.8 8 0.4 0 0.4 0.4 142 5 146 305 70 0 70 0 -6.4 0 -6.2 -6.7 04/24/2005 01:50:00 9.9 0.7 12.6 7.6 9.5 0.7 11.5 7.2 0.4 0 0.4 0.4 142 4 147 305 70 0 70 0 -6.5 0 -6.2 -6.7 04/24/2005 02:00:00 10.4 0.6 11.8 8.4 10.2 0.6 11.5 8.4 0.4 0 0.4 0.4 139 3 145 305 70 0 71 0 -6.6 0 -6.4 -6.9 04/24/2005 02:10:00 11 0.5 12.6 9.1 10.7 0.5 11.8 9.1 0.4 0 0.4 0.4 140 3 143 305 70 0 71 0 -6.7 0 -6.7 -6.9 04/24/2005 02:20:00 11.5 0.5 12.6 9.9 11.2 0.5 12.2 9.5 0.4 0 0.4 0.4 138 2 142 305 70 0 70 0 -6.7 0 -6.7 -6.9 04/24/2005 02:30:00 11.8 0.4 12.6 10.3 11.4 0.5 12.2 9.9 0.4 0 0.4 0.4 136 2 134 305 71 0 72 0 -6.4 0.1 -6 -6.7 04/24/2005 02:40:00 12.1 0.5 13 10.3 11.7 0.5 12.6 9.9 0.4 0 0.4 0.4 134 2 135 305 72 0 72 0 -5.9 0.1 -5.6 -6.2 04/24/2005 02:50:00 11.2 0.8 12.6 8.8 10.9 0.8 12.6 8.4 0.4 0 0.4 0.4 132 4 131 305 73 0 73 0 -5.6 0 -5.6 -5.8 04/24/2005 03:00:00 11.4 0.8 13 8.8 11.1 0.8 12.6 8.4 0.4 0 0.4 0.4 135 5 139 305 74 0 74 0 -5.8 0.1 -5.6 -6 04/24/2005 03:10:00 12.1 0.5 13 10.7 11.7 0.5 13 9.9 0.4 0 0.4 0.4 137 2 134 305 73 0 74 0 -6 0 -5.6 -6.2 04/24/2005 03:20:00 11.6 0.7 13 9.5 11.2 0.7 13 9.1 0.4 0 0.4 0.4 135 4 134 305 74 0 73 0 -5.6 0.1 -5.1 -6 04/24/2005 03:30:00 11.7 0.8 13.7 8.8 11.3 0.8 13 8.8 0.4 0 0.4 0.4 134 5 131 305 74 0 74 0 -5.3 0 -5.1 -5.6 04/24/2005 03:40:00 11.3 1.3 15.3 7.2 11 1.2 13.3 7.2 0.4 0 0.4 0.4 132 8 137 305 74 0 74 0 -5.1 0 -4.9 -5.3 04/24/2005 03:50:00 10.2 1.4 13.7 7.2 10 1.2 13 7.2 0.4 0 0.4 0.4 126 10 137 305 73 0 73 0 -5.3 0.1 -4.9 -5.6 04/24/2005 04:00:00 11.7 1.5 14.9 7.6 11.6 1.5 14.9 8 0.4 0 0.4 0.4 133 9 128 305 72 0 72 0 -5.2 0 -4.5 -5.3 04/24/2005 04:10:00 13.4 1 15.6 9.5 13 1 15.3 9.1 0.4 0 0.4 0.4 133 5 131 305 71 0 71 0 -5.6 0.1 -4.7 -5.8 04/24/2005 04:20:00 13.1 0.8 14.9 10.3 12.7 0.9 15.3 9.9 0.4 0 0.4 0.4 132 5 127 305 70 0 71 0 -5.7 0.2 -5.1 -6 04/24/2005 04:30:00 11.5 1.7 14.9 7.6 11.3 1.5 14.9 7.2 0.4 0 0.4 0.4 127 8 129 305 70 0 70 0 -5.5 0.1 -5.1 -6 04/24/2005 04:40:00 10.3 1.3 14.1 6.1 10.2 1.3 13.3 6.5 0.4 0 0.4 0.4 122 9 128 305 69 0 69 0 -5.7 0 -5.6 -5.8 04/24/2005 04:50:00 10.7 1.8 14.5 6.5 10.6 1.7 14.5 6.5 0.4 0 0.4 0.4 127 9 130 305 68 0 68 0 -5.6 0.1 -5.1 -5.8 04/24/2005 05:00:00 11.7 1.5 15.6 8 11.5 1.5 15.3 7.2 0.4 0 0.4 0.4 127 8 134 305 68 0 67 0 -5.5 0 -5.1 -5.8 04/24/2005 05:10:00 11.3 1.5 15.3 7.6 11.1 1.5 15.6 8 0.4 0 0.4 0.4 126 9 161 305 67 0 66 0 -5.5 0 -5.3 -5.8 04/24/2005 05:20:00 10.6 1.3 13.7 6.8 10.4 1.3 15.6 7.6 0.4 0 0.4 0.4 124 10 127 305 66 0 66 0 -5.6 0 -5.6 -5.8 04/24/2005 05:30:00 12.2 1.7 17.2 7.6 11.9 1.8 16.8 8 0.4 0 0.4 0.4 130 10 136 305 66 0 66 0 -5.5 0.2 -5.1 -5.8 04/24/2005 05:40:00 13.4 1.1 16.1 9.9 13 1.2 16.8 9.5 0.4 0 0.4 0.4 129 6 134 305 66 0 66 0 -5 0 -4.7 -5.1 04/24/2005 05:50:00 12.3 1.6 15.3 8.8 11.9 1.6 15.6 7.6 0.4 0 0.4 0.4 128 8 128 305 66 0 66 0 -4.9 0 -4.7 -5.1 04/24/2005 06:00:00 10.6 1.4 14.5 7.6 10.3 1.5 14.1 6.8 0.4 0 0.4 0.4 121 10 117 305 66 0 66 0 -5 0 -4.7 -5.1 04/24/2005 06:10:00 9.4 1.5 13.3 5.7 9 1.5 13.3 4.9 0.4 0 0.4 0.4 110 13 105 305 64 0 65 0 -5.2 0.1 -4.9 -5.6 04/24/2005 06:20:00 9.8 1.8 15.3 6.1 9.4 1.7 13.7 5.7 0.4 0 0.4 0.4 115 13 146 305 63 0 63 0 -5.5 0 -5.1 -5.8 04/24/2005 06:30:00 9.8 1.7 13.3 5.3 9.2 1.7 13 5.7 0.4 0 0.4 0.4 112 15 124 305 62 0 62 0 -5.2 0 -5.1 -5.3 04/24/2005 06:40:00 9.7 1.9 14.9 5.3 9.2 1.7 13.3 4.2 0.4 0 0.4 0.4 110 14 93 305 61 0 62 0 -5.1 0 -4.9 -5.6 04/24/2005 06:50:00 8.6 1.7 13.3 5.3 8.1 1.7 13 4.2 0.4 0 0.4 0.4 107 14 126 305 61 0 62 0 -5.1 0 -4.9 -5.3 04/24/2005 07:00:00 7.4 1.5 12.2 3.4 6.9 1.7 12.2 2.6 0.4 0 0.4 0.4 101 15 118 305 61 0 61 0 -5.2 0 -5.1 -5.3 04/24/2005 07:10:00 7 1.6 11.8 3.4 6.6 1.5 11.5 3 0.4 0 0.4 0.4 99 16 82 305 61 0 62 0 -4.9 0 -4.7 -5.1 04/24/2005 07:20:00 6.6 1.8 10.7 3 6.3 1.7 10.3 2.3 0.4 0 0.4 0.4 91 17 73 305 62 0 62 0 -4.7 0 -4.5 -4.7 04/24/2005 07:30:00 6.7 1.5 9.9 3.4 6.2 1.3 9.5 3 0.4 0 0.4 0.4 86 19 63 305 62 0 62 0 -4.5 0 -4.5 -4.7 04/24/2005 07:40:00 6 1.6 10.3 1.9 5.6 1.5 9.1 1.5 0.4 0 0.4 0.4 95 19 114 305 63 0 63 0 -4.4 0 -4.2 -4.7 04/24/2005 07:50:00 5.3 1.5 11.1 1.5 5 1.5 11.1 1.5 0.4 0 0.4 0.4 103 22 121 305 64 0 64 0 -4.3 0 -4 -4.5 04/24/2005 08:00:00 5.8 1.7 12.2 1.5 5.4 1.6 10.7 1.9 0.4 0 0.4 0.4 90 20 108 305 65 0 65 0 -4.1 0 -3.6 -4.2 04/24/2005 08:10:00 5.7 1.7 10.7 2.6 5.4 1.7 9.9 1.9 0.4 0 0.4 0.4 94 24 78 305 65 0 65 0 -4 0 -4 -4.2 04/24/2005 08:20:00 6.2 1.7 10.7 1.9 5.7 1.5 9.9 2.3 0.4 0 0.4 0.4 99 23 96 305 66 0 66 0 -4 0 -3.8 -4.2 04/24/2005 08:30:00 6.9 1.5 11.8 2.3 6.5 1.3 10.3 2.6 0.4 0 0.4 0.4 101 19 105 305 66 0 66 0 -4 0 -3.8 -4 04/24/2005 08:40:00 5.7 1.5 9.5 2.3 5.5 1.5 9.5 1.5 0.4 0 0.4 0.4 101 22 96 305 66 0 66 0 -4.1 0 -3.3 -4.2 04/24/2005 08:50:00 6.3 1.8 11.5 2.3 6 1.7 11.1 1.1 0.4 0 0.4 0.4 95 22 123 305 66 0 66 0 -3.9 0 -3.8 -4 04/24/2005 09:00:00 7 1.8 11.8 3 6.7 1.6 11.1 3.4 0.4 0 0.4 0.4 100 21 106 305 66 0 66 0 -3.7 0 -3.6 -4 04/24/2005 09:10:00 7.2 1.9 12.6 3.4 6.8 1.8 12.6 3 0.4 0 0.4 0.4 103 17 103 305 66 0 66 0 -3.6 0 -3.1 -3.8 04/24/2005 09:20:00 6.4 1.5 10.7 2.6 6.1 1.7 10.7 1.5 0.4 0 0.4 0.4 102 22 135 305 66 0 66 0 -3.7 0 -3.3 -4 04/24/2005 09:30:00 6.9 1.5 11.5 3.4 6.5 1.5 11.5 3.4 0.4 0 0.4 0.4 101 17 123 305 65 0 65 0 -4.1 0.1 -3.8 -4.2 04/24/2005 09:40:00 7.2 1.3 11.5 3.8 6.8 1.3 10.7 3.4 0.4 0 0.4 0.4 101 20 99 305 65 0 66 0 -4.1 0 -4 -4.5 04/24/2005 09:50:00 6.7 1.7 12.2 3 6.4 1.4 10.7 3.4 0.4 0 0.4 0.4 102 22 107 305 66 0 66 0 -4.2 0 -4 -4.5 04/24/2005 10:00:00 6.5 1.6 11.1 3 6 1.4 9.9 2.6 0.4 0 0.4 0.4 98 19 149 305 66 0 66 0 -4.1 0 -4 -4.2 04/24/2005 10:10:00 6.1 1.8 11.1 1.5 5.5 1.7 11.1 1.5 0.4 0 0.4 0.4 87 22 93 305 66 0 66 0 -4 0 -3.8 -4 04/24/2005 10:20:00 5.7 1.7 10.3 1.9 5.2 1.7 10.7 1.5 0.4 0 0.4 0.4 74 19 111 305 65 0 66 0 -4 0 -3.8 -4 04/24/2005 10:30:00 6 1.7 11.1 2.3 5.5 1.7 11.1 1.5 0.4 0 0.4 0.4 85 27 49 305 65 0 65 0 -3.9 0 -3.8 -4 04/24/2005 10:40:00 5.4 1.9 11.1 1.1 5.2 1.7 9.9 0.7 0.4 0 0.4 0.4 86 35 111 305 64 0 64 0 -3.9 0 -3.8 -4 04/24/2005 10:50:00 6.6 1.8 13 2.6 6.1 1.7 11.1 2.3 0.4 0 0.4 0.4 83 27 67 305 62 0 63 0 -3.9 0 -3.8 -4 04/24/2005 11:00:00 7.7 2.2 14.9 3 7.2 2.2 14.5 3 0.4 0 0.4 0.4 78 21 99 305 61 0 61 0 -3.7 0 -3.1 -3.8 04/24/2005 11:10:00 8.2 1.9 14.1 4.9 8 2 14.1 3.4 0.4 0 0.4 0.4 82 22 77 305 60 0 60 0 -3.6 0 -3.3 -3.8 04/24/2005 11:20:00 8.4 2.5 16.1 2.6 7.9 2.5 15.3 3 0.4 0 0.4 0.4 86 23 69 305 60 0 59 0 -3.3 0 -3.1 -3.6 04/24/2005 11:30:00 9.9 2.5 19.1 4.6 9.6 2.6 19.5 4.2 0.4 0 0.4 0.4 73 17 82 305 58 0 58 0 -3.5 0.1 -3.3 -3.8 04/24/2005 11:40:00 10.1 2.3 15.6 4.9 9.9 2.3 15.3 4.6 0.4 0 0.4 0.4 72 17 69 305 57 0 57 0 -3.6 0 -3.3 -3.8 04/24/2005 11:50:00 9.8 2.7 17.9 4.2 9.2 2.7 17.6 3.4 0.4 0 0.4 0.4 75 18 47 305 56 0 56 0 -3.5 0 -2.9 -3.8 04/24/2005 12:00:00 9.4 2.8 18.3 3.8 9.1 2.8 18.3 3 0.4 0 0.4 0.4 73 21 82 305 56 0 56 0 -3.6 0.1 -3.3 -3.8 04/24/2005 12:10:00 9.2 2.7 16.1 2.6 8.9 2.7 16.1 2.3 0.4 0 0.4 0.4 72 19 84 305 55 0 55 0 -3.5 0 -2.9 -3.8 04/24/2005 12:20:00 8.7 2.6 15.6 3.8 8.1 2.6 15.3 3.4 0.4 0 0.4 0.4 79 22 71 305 57 1 56 0 -3.3 0 -2.7 -3.6 04/24/2005 12:30:00 9.7 2.6 17.2 4.2 9.3 2.5 16.8 4.2 0.4 0 0.4 0.4 83 21 78 305 58 0 58 0 -3.5 0 -3.3 -3.8 04/24/2005 12:40:00 9.5 2.9 16.8 3.4 9.2 3.1 17.6 3.4 0.4 0 0.4 0.4 87 22 114 305 57 0 58 0 -3.4 0.1 -3.1 -3.8 04/24/2005 12:50:00 9.3 2.5 16.4 3.8 8.9 2.5 16.1 4.2 0.4 0 0.4 0.4 87 18 58 305 56 0 57 0 -3.3 0 -3.1 -3.6 04/24/2005 13:00:00 10 2.3 16.4 4.6 9.5 2.2 15.6 4.9 0.4 0 0.4 0.4 92 19 84 305 56 0 56 0 -3.3 0 -3.1 -3.6 04/24/2005 13:10:00 8.9 2 14.5 4.2 8.4 1.8 13.3 3 0.4 0 0.4 0.4 95 19 82 305 55 0 54 0 -3.2 0 -2.9 -3.3 04/24/2005 13:20:00 8.2 2.1 14.1 4.2 7.8 2 13.7 3.8 0.4 0 0.4 0.4 93 21 108 305 53 0 53 0 -3.3 0 -3.1 -3.3 04/24/2005 13:30:00 8.7 2.3 14.5 3.8 8 2.2 13.7 3.4 0.4 0 0.4 0.4 97 21 93 305 52 0 53 0 -3.1 0 -2.7 -3.3 04/24/2005 13:40:00 9.7 2.4 16.8 4.9 9.3 2.5 15.6 4.6 0.4 0 0.4 0.4 86 21 79 305 51 1 52 0 -3.2 0.1 -2.9 -3.3 04/24/2005 13:50:00 10 2.4 17.6 5.7 9.7 2.5 16.8 4.9 0.4 0 0.4 0.4 82 18 77 305 50 0 49 0 -3.2 0 -3.1 -3.3 04/24/2005 14:00:00 11 2.4 17.9 5.3 10.8 2.5 18.7 4.6 0.4 0 0.4 0.4 77 15 82 305 48 0 48 0 -3.3 0 -3.1 -3.3 04/24/2005 14:10:00 11.4 1.8 16.4 7.2 11.1 1.8 15.6 6.5 0.4 0 0.4 0.4 75 11 59 305 46 1 46 0 -3.3 0 -3.1 -3.3 04/24/2005 14:20:00 12 1.5 16.4 6.8 11.6 1.5 15.6 7.2 0.4 0 0.4 0.4 76 9 80 305 45 0 45 0 -3.3 0 -3.3 -3.3 04/24/2005 14:30:00 12.4 1.4 16.4 8.8 12 1.5 15.6 8 0.4 0 0.4 0.4 76 8 70 305 44 0 44 0 -3.4 0 -3.3 -3.8 04/24/2005 14:40:00 12.5 1.6 17.6 8.8 12.2 1.7 17.6 8 0.4 0 0.4 0.4 77 9 87 305 43 0 43 0 -3.6 0 -3.3 -3.8 04/24/2005 14:50:00 12.6 1.7 18.3 8.8 12.3 1.8 16.8 8.4 0.4 0 0.4 0.4 78 10 74 305 42 0 42 0 -3.6 0 -3.3 -3.8 04/24/2005 15:00:00 13 1.6 17.6 8.8 12.5 1.7 16.8 8 0.4 0 0.4 0.4 81 9 89 305 41 0 40 0 -3.6 0 -3.3 -3.8 04/24/2005 15:10:00 13.1 1.5 17.9 9.9 12.6 1.5 16.8 8.8 0.4 0 0.4 0.4 79 8 72 305 39 1 39 0 -3.5 0 -3.3 -3.8 04/24/2005 15:20:00 13.4 1.2 17.2 8.8 13.1 1.3 17.2 9.5 0.4 0 0.4 0.4 79 6 81 305 38 0 38 0 -3.6 0 -3.3 -3.8 04/24/2005 15:30:00 12.5 1 16.4 9.9 12.2 1.2 16.1 9.5 0.4 0 0.4 0.4 76 6 69 305 38 0 38 0 -3.7 0 -3.6 -3.8 04/24/2005 15:40:00 11.7 1 14.5 9.1 11.4 1.1 14.5 8.8 0.4 0 0.4 0.4 73 7 74 305 39 0 39 0 -3.8 0 -3.6 -3.8 04/24/2005 15:50:00 11 0.9 13.7 8.8 10.8 1 14.1 8 0.4 0 0.4 0.4 71 6 70 305 40 0 40 0 -3.8 0 -3.8 -3.8 04/24/2005 16:00:00 10.5 1 13.3 8 10.3 1 13 8 0.4 0 0.4 0.4 68 6 70 305 41 0 41 0 -3.9 0 -3.8 -4 04/24/2005 16:10:00 10.5 1.1 13 4.9 10.2 1.1 13 4.9 0.4 0 0.4 0.4 71 8 64 305 43 0 43 0 -3.8 0 -3.6 -4 04/24/2005 16:20:00 11 1.5 14.9 5.3 10.7 1.7 14.1 5.3 0.4 0 0.4 0.4 70 9 73 305 44 0 43 0 -3.7 0 -3.6 -3.8 04/24/2005 16:30:00 11.1 2.1 16.4 5.3 11 2.2 16.8 4.6 0.4 0 0.4 0.4 67 12 52 305 45 0 46 0 -3.7 0 -3.6 -3.8 04/24/2005 16:40:00 11.4 2.5 17.2 4.9 11.2 2.5 17.2 6.1 0.4 0 0.4 0.4 67 15 84 305 49 2 52 0 -3.9 0 -3.8 -4 04/24/2005 16:50:00 11.3 2.6 18.7 6.5 10.9 2.6 18.3 5.7 0.4 0 0.4 0.4 69 15 95 305 56 2 57 0 -3.8 0 -3.6 -4 04/24/2005 17:00:00 10.3 3.2 17.9 4.2 9.8 3.5 19.1 3.8 0.4 0 0.4 0.4 77 21 68 305 63 2 65 0 -3.6 0 -3.3 -3.8 04/24/2005 17:10:00 10.3 2.7 16.4 4.6 10 2.7 17.6 4.6 0.4 0 0.4 0.4 68 15 54 305 68 1 67 0 -3.5 0 -3.3 -3.8 04/24/2005 17:20:00 11.2 2.5 18.3 5.7 10.9 2.7 18.7 4.9 0.4 0 0.4 0.4 71 15 61 305 72 1 73 0 -3.5 0 -3.1 -3.8 04/24/2005 17:30:00 10.8 2.5 19.1 5.7 10.7 2.7 20.6 5.3 0.4 0 0.4 0.4 72 17 68 305 75 1 76 0 -3.5 0 -3.3 -3.8 04/24/2005 17:40:00 11.8 2.4 19.9 6.5 11.7 2.4 18.7 5.7 0.4 0 0.4 0.4 73 15 68 305 77 0 77 0 -3.4 0 -3.3 -3.6 04/24/2005 17:50:00 12.1 2.7 19.9 6.1 11.9 2.8 20.2 6.1 0.4 0 0.4 0.4 74 17 76 305 79 0 79 0 -3.3 0 -2.7 -3.3 04/24/2005 18:00:00 12.5 2.6 21 6.1 12.1 2.6 18.7 5.7 0.4 0 0.4 0.4 76 14 87 305 80 0 79 0 -3.2 0 -3.1 -3.3 04/24/2005 18:10:00 12.9 2.2 18.3 8 12.6 2.2 19.5 8 0.4 0 0.4 0.4 75 12 61 305 80 0 81 0 -3.3 0 -3.1 -3.3 04/24/2005 18:20:00 12.6 2.3 19.1 7.2 12.5 2.3 19.9 7.6 0.4 0 0.4 0.4 77 12 64 305 81 0 81 0 -3.3 0 -3.1 -3.3 04/24/2005 18:30:00 12.6 2.5 20.2 7.2 12.3 2.7 20.2 7.2 0.4 0 0.4 0.4 75 15 84 305 82 0 83 0 -3.3 0 -3.3 -3.3 04/24/2005 18:40:00 12 2.6 19.1 6.8 11.5 2.9 19.9 5.7 0.4 0 0.4 0.4 78 17 67 305 83 0 83 0 -3.3 0 -3.3 -3.6 04/24/2005 18:50:00 11.1 3.1 19.5 3.8 10.6 3.1 20.2 4.6 0.4 0 0.4 0.4 85 20 67 305 84 0 84 0 -3.3 0 -3.1 -3.3 04/24/2005 19:00:00 11.1 2.3 17.9 5.3 10.7 2.5 18.3 5.7 0.4 0 0.4 0.4 82 20 86 305 85 0 85 0 -3.3 0 -3.1 -3.3 04/24/2005 19:10:00 10.7 2.8 19.9 4.2 10.5 2.9 19.1 4.9 0.4 0 0.4 0.4 75 20 68 305 86 0 86 0 -3.2 0 -3.1 -3.3 04/24/2005 19:20:00 11.9 2.6 18.3 5.7 11.6 2.7 18.7 4.2 0.4 0 0.4 0.4 76 17 95 305 87 0 87 0 -3.1 0 -2.9 -3.3 04/24/2005 19:30:00 11.9 2.5 18.3 5.7 11.5 2.6 19.5 5.3 0.4 0 0.4 0.4 76 17 79 305 88 0 87 0 -3 0 -2.7 -3.1 04/24/2005 19:40:00 11.7 2.5 17.6 4.9 11.3 2.6 17.9 5.3 0.4 0 0.4 0.4 77 19 75 305 89 0 88 0 -2.8 0 -2.7 -3.1 04/24/2005 19:50:00 10.6 2.3 19.1 5.3 10 2.6 17.9 4.2 0.4 0 0.4 0.4 85 22 78 305 89 0 89 0 -2.8 0 -2.7 -2.9 04/24/2005 20:00:00 9.3 2.4 16.8 3.8 8.9 2.5 16.1 4.2 0.4 0 0.4 0.4 90 22 84 305 90 0 90 0 -2.7 0 -2.7 -2.7 04/24/2005 20:10:00 9 2.2 15.6 3.8 8.3 2.2 16.1 3 0.4 0 0.4 0.4 103 20 131 305 91 1 91 0 -2.6 0 -2.4 -2.7 04/24/2005 20:20:00 8.7 2.1 14.5 4.2 8 2 15.3 3.8 0.4 0 0.4 0.4 100 23 99 305 93 1 93 0 -2.5 0 -2.4 -2.7 04/24/2005 20:30:00 7.7 1.8 13 4.2 7.3 1.8 14.1 3.4 0.4 0 0.4 0.4 96 22 53 305 94 0 93 0 -2.4 0 -2.2 -2.4 04/24/2005 20:40:00 8.1 2.1 13.7 3.8 7.8 2.2 14.1 3 0.4 0 0.4 0.4 100 24 128 305 95 0 94 0 -2.4 0 -2 -2.7 04/24/2005 20:50:00 8.1 2.4 18.3 3.4 7.8 2.2 17.2 3 0.4 0 0.4 0.4 85 22 88 305 95 0 94 0 -2.3 0 -2 -2.4 04/24/2005 21:00:00 9.1 2.4 16.4 3.4 8.8 2.6 16.4 3 0.4 0 0.4 0.4 72 19 70 305 95 0 95 0 -2 0 -1.5 -2.2 04/24/2005 21:10:00 9.3 2.6 17.2 4.9 9 2.7 19.1 3 0.4 0 0.4 0.4 66 18 68 305 95 0 95 0 -1.8 0 -1.3 -2 04/24/2005 21:20:00 7.8 2.1 16.8 3 7.5 2.2 14.9 2.3 0.4 0 0.4 0.4 74 24 74 305 95 0 95 0 -1.6 0 -1.1 -1.8 04/24/2005 21:30:00 7.8 2.4 14.9 3 7.5 2.5 15.6 2.3 0.4 0 0.4 0.4 102 23 78 305 95 0 94 0 -1.5 0 -1.3 -1.8 04/24/2005 21:40:00 9.4 2.4 16.1 3.4 8.9 2.4 17.9 2.6 0.4 0 0.4 0.4 109 20 123 305 94 0 94 0 -1.6 0 -1.3 -1.8 04/24/2005 21:50:00 8.6 2.4 15.3 3.4 8.2 2.5 15.6 1.9 0.4 0 0.4 0.4 105 22 108 305 94 0 94 0 -1.6 0 -1.3 -1.8 04/24/2005 22:00:00 10.4 2.4 17.6 4.9 10.1 2.3 16.4 5.3 0.4 0 0.4 0.4 112 19 106 305 94 0 94 0 -1.6 0 -1.3 -1.8 04/24/2005 22:10:00 10.3 2.7 18.7 5.3 9.7 2.7 19.9 3.4 0.4 0 0.4 0.4 110 17 90 305 94 0 94 0 -1.8 0 -1.8 -2 04/24/2005 22:20:00 9.8 2.4 16.8 5.7 9.4 2.4 16.4 4.6 0.4 0 0.4 0.4 101 18 96 305 94 0 94 0 -1.8 0 -1.8 -2 04/24/2005 22:30:00 9.9 2.4 18.3 4.9 9.4 2.5 18.3 4.6 0.4 0 0.4 0.4 88 21 112 305 95 0 95 0 -1.8 0 -1.8 -2 04/24/2005 22:40:00 10.3 2.5 18.3 4.6 9.9 2.5 16.1 4.2 0.4 0 0.4 0.4 82 18 90 305 95 0 95 0 -1.7 0 -1.3 -2 04/24/2005 22:50:00 11 2 17.6 6.5 10.8 2.1 16.1 5.7 0.4 0 0.4 0.4 72 13 66 305 95 0 95 0 -1.7 0 -1.8 -1.8 04/24/2005 23:00:00 11.8 1.8 16.8 5.7 11.7 1.9 17.9 6.1 0.4 0 0.4 0.4 68 9 77 305 96 0 95 0 -1.7 0 -1.8 -1.8 04/24/2005 23:10:00 11.9 1.7 20.6 7.6 11.8 1.7 17.2 6.5 0.4 0 0.4 0.4 68 10 56 305 96 0 96 0 -1.7 0 -1.8 -1.8 04/24/2005 23:20:00 11.8 1.9 17.6 6.8 11.6 2 16.8 7.2 0.4 0 0.4 0.4 66 12 62 305 97 0 97 0 -1.7 0 -1.8 -1.8 04/24/2005 23:30:00 11.5 2.6 19.1 5.3 11.3 2.8 19.1 3 0.4 0 0.4 0.4 69 17 70 305 97 0 97 0 -1.7 0 -1.8 -1.8 04/24/2005 23:40:00 11.5 2.4 18.3 5.3 11.3 2.6 17.9 5.3 0.4 0 0.4 0.4 67 13 72 305 98 0 97 0 -1.6 0 -1.1 -1.8 04/24/2005 23:50:00 11.4 1.9 17.9 6.8 11.3 2 17.2 7.2 0.4 0 0.4 0.4 64 10 66 305 97 0 97 0 -1.4 0 -1.3 -1.8 04/25/2005 00:00:00 11.2 2.3 18.3 5.3 11 2.4 19.9 5.3 0.4 0 0.4 0.4 66 12 66 305 97 0 97 0 -1.1 0 -0.6 -1.3 04/25/2005 00:10:00 10.5 1.9 14.9 6.5 10.3 2 14.9 5.7 0.4 0 0.4 0.4 65 12 75 305 98 0 97 0 -1.1 0 -0.6 -1.1 04/25/2005 00:20:00 9.9 1.9 15.6 6.1 9.7 2 16.4 4.9 0.4 0 0.4 0.4 64 11 65 305 98 0 97 0 -0.9 0 -0.4 -1.1 04/25/2005 00:30:00 10.5 1.6 15.3 5.7 10.4 1.6 14.5 4.9 0.4 0 0.4 0.4 66 9 73 305 98 0 97 0 -0.7 0 -0.4 -0.8 04/25/2005 00:40:00 9.9 2 16.4 4.9 9.7 2.1 16.1 4.9 0.4 0 0.4 0.4 68 15 84 305 97 0 98 0 -0.7 0 -0.1 -0.8 04/25/2005 00:50:00 9.5 1.9 14.1 4.6 9 2 13.3 4.6 0.4 0 0.4 0.4 70 15 51 305 97 0 97 0 -0.7 0 -0.4 -1.1 04/25/2005 01:00:00 9.7 2.5 16.1 3.8 9.3 2.5 15.6 3.8 0.4 0 0.4 0.4 71 18 84 305 97 0 97 0 -0.7 0 -0.1 -0.8 04/25/2005 01:10:00 9 2.4 15.3 3 8.6 2.2 14.9 3 0.4 0 0.4 0.4 77 18 84 305 97 0 97 0 -0.6 0 0.1 -0.6 04/25/2005 01:20:00 8.9 2.3 15.6 3.4 8.3 2.2 13.7 3.4 0.4 0 0.4 0.4 107 22 108 305 97 0 96 0 -0.6 0 0.1 -0.6 04/25/2005 01:30:00 7.5 2.3 14.9 2.6 7.2 2.3 13.7 2.6 0.4 0 0.4 0.4 106 21 123 305 97 0 97 0 -0.5 0.1 0.1 -0.6 04/25/2005 01:40:00 8.2 1.9 13.7 2.3 7.8 2 13.3 1.5 0.4 0 0.4 0.4 109 23 116 305 97 0 97 0 -0.2 0 0.3 -0.4 04/25/2005 01:50:00 8.5 2.7 20.6 3.4 8.2 2.6 17.9 3 0.4 0 0.4 0.4 107 23 120 305 97 0 97 0 -0.4 0.1 0.1 -0.6 04/25/2005 02:00:00 9.6 2.3 16.8 4.6 9.1 2.2 15.6 3.8 0.4 0 0.4 0.4 112 20 129 305 97 0 96 0 -0.6 0 0.1 -0.6 04/25/2005 02:10:00 11 2.2 16.8 4.2 10.6 2.2 17.9 4.9 0.4 0 0.4 0.4 119 17 129 305 97 0 97 0 -0.7 0 -0.1 -0.8 04/25/2005 02:20:00 14.3 2.7 20.2 6.5 13.8 2.7 19.9 6.5 0.4 0 0.4 0.4 121 14 135 305 98 0 98 0 -0.8 0 -0.4 -1.1 04/25/2005 02:30:00 14.4 2.4 22.6 8.8 14 2.5 20.2 7.2 0.4 0 0.4 0.4 121 11 124 305 99 0 99 0 -0.8 0 -0.4 -1.1 04/25/2005 02:40:00 13.4 2.5 19.9 8 13 2.5 19.9 7.6 0.4 0 0.4 0.4 123 15 130 305 99 0 100 0 -0.8 0 -0.4 -1.1 04/25/2005 02:50:00 14 2.3 20.6 8.8 13.7 2.3 20.6 8.8 0.4 0 0.4 0.4 124 13 123 305 100 0 100 0 -0.8 0 -0.4 -1.1 04/25/2005 03:00:00 14 2.2 19.9 9.1 13.5 2.2 19.1 8 0.4 0 0.4 0.4 123 12 116 305 100 0 100 0 -0.8 0 -0.4 -0.8 04/25/2005 03:10:00 14.1 2.4 22.6 8 14 2.3 23.7 8.4 0.4 0 0.4 0.4 124 14 122 305 100 0 101 0 -0.6 0 -0.1 -0.6 04/25/2005 03:20:00 13.8 2.2 19.9 9.1 13.6 2.2 19.9 8.8 0.4 0 0.4 0.4 127 14 118 305 101 0 101 0 -0.6 0 -0.1 -0.6 04/25/2005 03:30:00 13.6 1.8 18.3 8.8 13.4 1.8 19.1 8.8 0.4 0 0.4 0.4 126 14 138 305 101 0 101 0 -0.5 0 0.1 -0.6 04/25/2005 03:40:00 14.2 1.8 19.9 9.1 13.9 1.9 20.2 8.4 0.4 0 0.4 0.4 129 12 136 305 101 0 101 0 -0.5 0 0.1 -0.6 04/25/2005 03:50:00 14.6 2 21.4 9.1 14.5 2.2 21.4 8.4 0.4 0 0.4 0.4 131 13 133 305 101 0 101 0 -0.5 0.1 0.1 -0.6 04/25/2005 04:00:00 15.1 2.1 21.8 9.9 14.8 2.2 22.1 9.5 0.4 0 0.4 0.4 130 13 136 305 101 0 101 0 -0.5 0 0.1 -0.6 04/25/2005 04:10:00 15 2.1 22.1 10.3 14.8 2.2 22.1 9.9 0.4 0 0.4 0.4 131 12 139 305 100 1 100 0 -0.5 0 0.1 -0.6 04/25/2005 04:20:00 14.7 2.2 21.4 9.5 14.6 2.3 21.4 7.6 0.4 0 0.4 0.4 130 12 134 305 101 1 99 0 -0.5 0 0.1 -0.6 04/25/2005 04:30:00 14.9 2.1 22.1 9.1 14.7 2.1 21.4 9.5 0.4 0 0.4 0.4 128 11 140 305 102 0 102 0 -0.5 0 0.1 -0.6 04/25/2005 04:40:00 14.4 2.1 21 10.3 14.1 2 21 9.9 0.4 0 0.4 0.4 126 14 129 305 102 0 101 0 -0.5 0 -0.1 -0.6 04/25/2005 04:50:00 14.7 2.2 20.6 8.8 14.6 2.2 21.8 8 0.4 0 0.4 0.4 131 13 120 305 103 1 103 0 -0.5 0 0.1 -0.6 04/25/2005 05:00:00 14.5 2.2 22.6 8 14.3 2.2 21.4 9.5 0.4 0 0.4 0.4 131 13 112 305 103 0 103 0 -0.5 0 0.1 -0.6 04/25/2005 05:10:00 15.2 2.2 20.6 9.9 14.9 2.1 21 9.5 0.4 0 0.4 0.4 129 12 132 305 104 0 103 0 -0.5 0.1 0.1 -0.6 04/25/2005 05:20:00 13.8 1.8 19.9 9.5 13.5 1.8 19.5 6.8 0.4 0 0.4 0.4 129 11 139 305 103 2 100 0 -0.5 0.1 0.1 -0.6 04/25/2005 05:30:00 13.7 2 21.4 9.5 13.4 2.1 21.4 9.5 0.4 0 0.4 0.4 127 13 129 305 101 1 101 0 -0.4 0.1 0.1 -0.6 04/25/2005 05:40:00 13.1 2.2 19.1 7.6 12.8 2.2 18.3 7.6 0.4 0 0.4 0.4 123 13 113 305 100 1 103 0 -0.3 0.1 0.1 -0.4 04/25/2005 05:50:00 13.6 2 20.2 7.2 13.4 2 19.9 8.4 0.4 0 0.4 0.4 130 13 142 305 100 1 100 0 -0.3 0.1 0.1 -0.4 04/25/2005 06:00:00 13.8 2.3 20.2 8.4 13.5 2.3 19.1 7.6 0.4 0 0.4 0.4 130 12 148 305 99 1 98 0 -0.4 0.2 0.1 -0.4 04/25/2005 06:10:00 14.6 2.1 19.5 8.4 14.3 1.9 19.5 8.4 0.4 0 0.4 0.4 130 11 143 305 98 1 98 0 -0.3 0.1 0.3 -0.4 04/25/2005 06:20:00 12.5 2 17.9 6.5 12.4 2 17.6 6.8 0.4 0 0.4 0.4 129 13 132 305 99 1 99 0 -0.3 0.1 0.1 -0.4 04/25/2005 06:30:00 12.8 1.9 18.3 8 12.6 1.9 18.7 6.8 0.4 0 0.4 0.4 128 12 130 305 99 1 98 0 -0.3 0.1 0.3 -0.4 04/25/2005 06:40:00 14.5 1.7 21 10.3 14 1.8 19.9 9.9 0.4 0 0.4 0.4 132 11 140 305 99 1 101 0 -0.1 0 0.3 -0.4 04/25/2005 06:50:00 13.4 1.7 18.3 9.1 13.2 1.7 17.6 8.4 0.4 0 0.4 0.4 130 10 147 305 99 1 99 0 0 0 0.6 -0.4 04/25/2005 07:00:00 12.2 1.9 19.5 7.6 12 1.9 17.9 7.6 0.4 0 0.4 0.4 130 11 135 305 99 1 99 0 0 0 0.6 -0.1 04/25/2005 07:10:00 12.5 1.9 17.9 8.4 12.2 2 17.6 7.6 0.4 0 0.4 0.4 130 12 128 305 99 1 100 0 0 0 0.6 -0.1 04/25/2005 07:20:00 12.4 1.9 17.6 7.6 12.3 1.9 18.3 6.5 0.4 0 0.4 0.4 130 11 137 305 99 1 98 0 0 0 0.6 -0.1 04/25/2005 07:30:00 12.4 1.9 18.3 7.2 12.2 1.9 18.3 7.2 0.4 0 0.4 0.4 128 13 133 305 99 1 100 0 -0.1 0 0.6 -0.4 04/25/2005 07:40:00 12.4 1.7 17.6 8 12.1 1.7 17.2 6.8 0.4 0 0.4 0.4 123 13 123 305 100 1 101 0 -0.1 0 0.3 -0.4 04/25/2005 07:50:00 12.8 1.7 17.6 7.6 12.6 1.9 18.3 7.6 0.4 0 0.4 0.4 127 12 129 305 100 1 99 0 -0.1 0 0.3 -0.4 04/25/2005 08:00:00 13 1.8 19.1 8.4 12.8 1.9 18.3 8.8 0.4 0 0.4 0.4 130 11 147 305 100 1 99 0 -0.2 0 0.1 -0.4 04/25/2005 08:10:00 11.8 2 17.9 7.2 11.5 2 16.8 7.2 0.4 0 0.4 0.4 128 13 105 305 99 1 101 0 -0.1 0 0.3 -0.4 04/25/2005 08:20:00 12.5 1.9 16.8 7.6 12.3 1.9 17.6 6.5 0.4 0 0.4 0.4 127 13 145 305 100 1 102 0 -0.1 0 0.3 -0.1 04/25/2005 08:30:00 12.7 2 19.1 8 12.5 1.9 18.3 7.6 0.4 0 0.4 0.4 130 12 130 305 100 1 99 0 0 0 0.6 -0.1 04/25/2005 08:40:00 11.9 2 20.6 7.2 11.5 2 17.9 7.2 0.4 0 0.4 0.4 127 13 160 305 99 1 102 0 0 0 0.3 0.1 04/25/2005 08:50:00 11 1.8 16.8 6.8 10.8 1.8 17.2 7.2 0.4 0 0.4 0.4 129 13 151 305 98 1 97 0 0 0.1 0.6 0.1 04/25/2005 09:00:00 10.5 2 16.1 6.1 10.4 2 16.4 6.1 0.4 0 0.4 0.4 131 12 128 305 98 1 97 0 0.2 0.1 0.6 0.1 04/25/2005 09:10:00 11.2 1.9 17.6 6.5 11 1.9 17.2 6.5 0.4 0 0.4 0.4 132 11 150 305 98 1 97 0 0.4 0 1 0.3 04/25/2005 09:20:00 10.7 1.7 16.4 6.8 10.5 1.7 16.1 6.1 0.4 0 0.4 0.4 130 13 138 305 99 1 99 0 0.5 0 1 0.3 04/25/2005 09:30:00 10.9 1.7 15.3 6.1 10.6 1.7 15.6 5.7 0.4 0 0.4 0.4 133 13 139 305 100 1 101 0 0.5 0 1 0.6 04/25/2005 09:40:00 10.4 1.6 14.5 6.5 10.1 1.5 13.3 5.7 0.4 0 0.4 0.4 133 11 123 305 100 1 99 0 0.5 0 1 0.6 04/25/2005 09:50:00 10.8 1.3 14.1 7.2 10.3 1.3 14.5 7.2 0.4 0 0.4 0.4 131 8 149 305 101 1 101 0 0.5 0 1 0.6 04/25/2005 10:00:00 11.3 1.3 15.6 8.4 11.2 1.3 15.3 8.4 0.4 0 0.4 0.4 130 11 147 305 101 1 101 0 0.7 0.1 1.3 0.6 04/25/2005 10:10:00 11.9 1.5 17.2 7.6 11.6 1.5 16.1 7.2 0.4 0 0.4 0.4 131 9 154 305 102 1 103 0 0.8 0 1.3 0.6 04/25/2005 10:20:00 11.9 1.5 15.6 7.6 11.8 1.6 15.3 7.2 0.4 0 0.4 0.4 131 9 135 305 103 1 103 0 0.8 0 1.3 0.6 04/25/2005 10:30:00 12.9 1.3 16.4 9.9 12.6 1.4 16.8 8.4 0.4 0 0.4 0.4 130 8 122 305 103 1 103 0 0.7 0 1.3 0.6 04/25/2005 10:40:00 12.3 1.7 16.4 6.8 12.1 1.7 16.4 6.8 0.4 0 0.4 0.4 130 12 143 305 102 0 102 0 0.8 0 1.3 0.6 04/25/2005 10:50:00 13.2 1.6 16.8 8.4 12.9 1.7 17.2 8 0.4 0 0.4 0.4 131 7 140 305 102 0 103 0 0.9 0 1.3 0.6 04/25/2005 11:00:00 12.6 1.3 16.4 9.1 12.2 1.2 16.1 8.8 0.4 0 0.4 0.4 133 6 130 305 103 0 103 0 1 0 1.5 0.8 04/25/2005 11:10:00 11.9 1.2 14.5 7.6 11.6 1.3 14.9 8 0.4 0 0.4 0.4 134 6 130 305 103 1 102 0 1.3 0.1 1.7 1 04/25/2005 11:20:00 12.4 1.1 14.9 8.8 11.9 1.1 14.5 9.1 0.4 0 0.4 0.4 134 5 137 305 99 1 99 0 1.4 0 2 1.3 04/25/2005 11:30:00 11.8 1.2 14.5 8.8 11.5 1.2 14.1 8.4 0.4 0 0.4 0.4 132 5 128 305 97 0 97 0 1.5 0 2 1.3 04/25/2005 11:40:00 12.1 1.1 14.5 9.1 11.9 1.2 15.6 8.8 0.4 0 0.4 0.4 131 8 131 305 91 3 89 0 1.4 0 2 1.3 04/25/2005 11:50:00 10.4 1.7 14.9 6.5 10.2 1.6 15.3 6.5 0.4 0 0.4 0.4 128 12 147 305 87 1 87 0 1.5 0 2 1.3 04/25/2005 12:00:00 9.1 1.3 12.6 6.1 9 1.3 13 5.7 0.4 0 0.4 0.4 124 13 116 305 84 1 84 0 1.6 0.1 2.2 1.3 04/25/2005 12:10:00 8.5 1.3 11.5 4.6 8.4 1.3 11.8 4.6 0.4 0 0.4 0.4 129 13 137 305 81 0 82 0 1.7 0.1 2.2 1.5 04/25/2005 12:20:00 9.1 1.6 13 4.9 8.8 1.5 12.2 5.3 0.4 0 0.4 0.4 120 12 123 305 80 0 80 0 1.9 0.1 2.5 1.7 04/25/2005 12:30:00 9.2 1.3 12.2 5.3 8.9 1.4 12.2 4.6 0.4 0 0.4 0.4 120 12 119 305 79 0 79 0 1.9 0.2 2.5 1.5 04/25/2005 12:40:00 8.2 1.5 13 4.6 8.1 1.5 12.2 4.6 0.4 0 0.4 0.4 121 12 112 305 78 0 78 0 1.7 0.1 2.2 1.5 04/25/2005 12:50:00 8.8 1.9 14.1 4.6 8.8 1.8 13.7 4.9 0.4 0 0.4 0.4 129 13 143 305 78 0 78 0 1.7 0.2 2.2 1.5 04/25/2005 13:00:00 9.7 1.2 13.3 6.5 9.5 1.1 13 7.2 0.4 0 0.4 0.4 133 6 127 305 78 0 78 0 1.7 0.2 2.2 1.5 04/25/2005 13:10:00 9.8 0.9 11.8 7.2 9.5 1 11.8 7.2 0.4 0 0.4 0.4 131 6 137 305 78 0 78 0 1.6 0.1 2.2 1.5 04/25/2005 13:20:00 9.9 1.1 12.6 6.8 9.7 1.1 13 6.8 0.4 0 0.4 0.4 129 6 122 305 79 0 79 0 1.7 0.1 2.2 1.5 04/25/2005 13:30:00 8.7 0.9 11.5 5.7 8.5 0.9 11.1 5.3 0.4 0 0.4 0.4 132 7 129 305 79 0 79 0 1.7 0.2 2.2 1.5 04/25/2005 13:40:00 8.2 1.2 11.5 4.9 8.1 1.1 11.1 4.9 0.4 0 0.4 0.4 131 9 124 305 80 0 80 0 1.6 0.1 2.2 1.5 04/25/2005 13:50:00 6.4 1 9.1 3.8 6.4 1 8.8 3.8 0.4 0 0.4 0.4 122 14 108 305 81 0 81 0 1.7 0.1 2.2 1.5 04/25/2005 14:00:00 5.5 1.2 9.9 3 5.3 1.2 8.8 2.6 0.4 0 0.4 0.4 116 19 150 305 81 0 82 0 1.8 0.2 2.5 1.5 04/25/2005 14:10:00 6.1 1.5 9.9 2.6 5.8 1.3 10.3 2.6 0.4 0 0.4 0.4 111 15 114 305 81 0 82 0 1.8 0.1 2.5 1.5 04/25/2005 14:20:00 6.6 1.3 11.1 3.8 6.4 1.3 10.7 3.4 0.4 0 0.4 0.4 112 14 109 305 81 0 82 0 1.7 0.1 2.2 1.5 04/25/2005 14:30:00 6.8 1.4 10.7 3 6.6 1.4 10.3 3.4 0.4 0 0.4 0.4 111 15 98 305 81 0 81 0 1.4 0.2 2 1.3 04/25/2005 14:40:00 7.6 1.3 11.1 4.2 7.4 1.3 11.5 3.8 0.4 0 0.4 0.4 107 15 141 305 83 0 83 0 1.2 0.1 2 1 04/25/2005 14:50:00 8.2 1.5 11.8 3.8 7.9 1.4 11.5 4.2 0.4 0 0.4 0.4 102 15 121 305 84 0 84 0 1.2 0.2 2 1 04/25/2005 15:00:00 8.5 1.3 12.6 5.3 8.2 1.3 14.1 4.9 0.4 0 0.4 0.4 107 12 108 305 86 0 86 0 1.2 0.2 1.7 1 04/25/2005 15:10:00 8.2 1.2 11.1 5.7 8 1.1 10.7 5.3 0.4 0 0.4 0.4 116 12 108 305 88 0 87 0 1.2 0.2 1.7 1 04/25/2005 15:20:00 8.4 1.2 12.2 5.3 8.3 1.3 11.5 4.9 0.4 0 0.4 0.4 121 11 110 305 89 0 89 0 1.2 0.2 1.7 1 04/25/2005 15:30:00 8.5 1.2 11.8 5.7 8.3 1.2 11.5 5.3 0.4 0 0.4 0.4 122 12 118 305 90 1 90 0 1.2 0.1 1.5 1 04/25/2005 15:40:00 8.7 1.2 12.6 4.9 8.6 1.1 11.1 5.3 0.4 0 0.4 0.4 135 10 141 305 92 0 91 0 1.1 0.1 1.5 1 04/25/2005 15:50:00 8.8 0.9 11.1 5.3 8.7 0.8 10.7 5.7 0.4 0 0.4 0.4 130 6 136 305 92 0 92 0 1.1 0 1.5 1 04/25/2005 16:00:00 9.9 0.8 11.8 8 9.8 0.8 11.5 7.6 0.4 0 0.4 0.4 131 5 136 305 93 0 93 0 1.1 0.1 1.5 1 04/25/2005 16:10:00 10.7 1 13.7 8 10.6 1 16.1 8 0.4 0 0.4 0.4 127 6 120 305 93 0 93 0 1.2 0.1 1.7 1 04/25/2005 16:20:00 10.1 1.2 14.1 6.8 9.9 1.3 13.7 6.8 0.4 0 0.4 0.4 123 11 141 305 92 0 92 0 1.2 0.1 1.5 1 04/25/2005 16:30:00 11.1 1.3 14.9 7.2 10.9 1.3 14.9 6.8 0.4 0 0.4 0.4 118 9 124 305 92 0 92 0 1.1 0 1.5 1 04/25/2005 16:40:00 10.5 1.3 13.3 7.2 10.4 1.3 13.3 6.8 0.4 0 0.4 0.4 123 11 121 305 91 0 92 0 1.1 0 1.5 1 04/25/2005 16:50:00 10.1 1.2 14.5 6.8 10 1.2 14.5 6.8 0.4 0 0.4 0.4 127 9 127 305 91 0 91 0 1.2 0.1 1.5 1 04/25/2005 17:00:00 10.2 1.1 12.6 6.1 10.1 1.1 12.6 5.3 0.4 0 0.4 0.4 129 9 135 305 92 0 92 0 1.1 0 1.5 1 04/25/2005 17:10:00 10.5 1.1 13 6.5 10.4 1.2 13.7 6.5 0.4 0 0.4 0.4 128 6 129 305 92 0 92 0 1.1 0 1.5 1 04/25/2005 17:20:00 10.4 1.5 16.4 6.5 10.1 1.6 16.4 6.5 0.4 0 0.4 0.4 123 11 127 305 92 0 92 0 1.2 0 1.7 1 04/25/2005 17:30:00 11.3 1.3 14.9 7.6 11.2 1.3 14.9 8 0.4 0 0.4 0.4 120 9 129 305 92 0 92 0 1.2 0 1.7 1 04/25/2005 17:40:00 11.1 1.4 14.5 6.8 11 1.4 14.5 6.5 0.4 0 0.4 0.4 119 9 116 305 92 0 92 0 1.1 0 1.5 1 04/25/2005 17:50:00 10 1.3 13 6.8 9.8 1.3 12.6 6.8 0.4 0 0.4 0.4 117 8 116 305 92 0 92 0 1.1 0 1.5 1 04/25/2005 18:00:00 10.1 1.3 13.7 7.2 9.9 1.3 14.1 6.8 0.4 0 0.4 0.4 117 9 127 305 92 0 92 0 1 0 1.3 0.8 04/25/2005 18:10:00 9.4 1.1 12.6 6.1 9.2 1.1 12.6 6.5 0.4 0 0.4 0.4 117 9 114 305 92 0 92 0 1 0 1.3 1 04/25/2005 18:20:00 8.9 1.3 12.6 5.7 8.7 1.3 12.2 5.7 0.4 0 0.4 0.4 118 11 120 305 93 0 93 0 1 0 1.3 1 04/25/2005 18:30:00 9 1 11.8 6.1 8.8 1 11.1 6.1 0.4 0 0.4 0.4 118 10 105 305 93 0 93 0 1.1 0 1.5 1 04/25/2005 18:40:00 9.5 1.1 13.3 6.5 9.3 1.1 13 6.5 0.4 0 0.4 0.4 118 8 117 305 93 0 93 0 1 0 1.5 1 04/25/2005 18:50:00 9.8 1.1 13 6.1 9.5 1.1 12.2 6.1 0.4 0 0.4 0.4 121 8 116 305 92 0 93 0 1 0 1.3 1 04/25/2005 19:00:00 10.3 1.1 13.7 7.2 10.1 1.1 13.7 6.8 0.4 0 0.4 0.4 121 8 118 305 92 0 93 0 1 0 1.5 0.8 04/25/2005 19:10:00 10 1.3 14.5 6.1 10 1.2 14.1 6.8 0.4 0 0.4 0.4 126 9 130 305 93 0 94 0 0.9 0 1.5 0.8 04/25/2005 19:20:00 11.1 1.2 13.3 7.2 10.9 1.1 14.1 7.6 0.4 0 0.4 0.4 129 6 129 305 94 0 94 0 0.9 0 1.3 0.8 04/25/2005 19:30:00 11.4 0.8 13.3 9.1 11.2 0.8 13 8.8 0.4 0 0.4 0.4 131 4 134 305 94 0 95 0 0.9 0 1.3 0.8 04/25/2005 19:40:00 11.6 0.7 13.3 8.4 11.4 0.7 13 9.1 0.4 0 0.4 0.4 130 3 129 305 95 0 95 0 0.9 0.1 1.3 0.6 04/25/2005 19:50:00 12 0.7 13.3 8.8 11.8 0.8 13.7 8.8 0.4 0 0.4 0.4 130 3 125 305 96 0 96 0 0.8 0.1 1.3 0.6 04/25/2005 20:00:00 11.8 0.8 13.7 8.4 11.5 0.8 13.3 7.6 0.4 0 0.4 0.4 130 4 119 305 97 0 97 0 0.7 0.1 1.3 0.6 04/25/2005 20:10:00 11.9 0.8 13.7 9.5 11.7 0.9 13.7 8.8 0.4 0 0.4 0.4 130 3 129 305 98 0 97 0 0.6 0 1 0.6 04/25/2005 20:20:00 11.5 0.5 12.6 9.9 11.2 0.6 12.6 9.5 0.4 0 0.4 0.4 130 3 131 305 98 0 98 0 0.5 0 1 0.6 04/25/2005 20:30:00 11.4 0.6 12.6 9.5 11.2 0.6 12.6 9.1 0.4 0 0.4 0.4 132 3 129 305 99 0 99 0 0.5 0 1 0.6 04/25/2005 20:40:00 11.8 0.6 14.1 9.9 11.5 0.7 13 9.5 0.4 0 0.4 0.4 129 3 118 305 100 0 100 0 0.5 0 1 0.6 04/25/2005 20:50:00 12.3 0.6 13.7 9.9 12 0.7 13.3 9.5 0.4 0 0.4 0.4 129 3 128 305 100 0 100 0 0.5 0 0.8 0.3 04/25/2005 21:00:00 12 0.6 13.7 10.7 11.7 0.6 13.3 9.9 0.4 0 0.4 0.4 130 3 130 305 101 0 101 0 0.5 0 0.8 0.3 04/25/2005 21:10:00 12 0.5 13.3 10.3 11.7 0.5 13 10.3 0.4 0 0.4 0.4 130 2 130 305 101 0 101 0 0.5 0 0.8 0.3 04/25/2005 21:20:00 11.9 0.5 13.3 10.3 11.6 0.5 13 9.5 0.4 0 0.4 0.4 131 2 131 305 101 0 101 0 0.4 0 0.8 0.3 04/25/2005 21:30:00 11.8 0.5 13 9.9 11.6 0.5 13 9.5 0.4 0 0.4 0.4 130 2 126 305 101 0 101 0 0.4 0 0.8 0.3 04/25/2005 21:40:00 12 0.5 13 10.3 11.8 0.6 13 10.3 0.4 0 0.4 0.4 130 2 130 305 101 0 102 0 0.4 0 0.8 0.3 04/25/2005 21:50:00 11.7 0.4 12.6 9.9 11.5 0.5 12.6 9.5 0.4 0 0.4 0.4 131 2 130 305 102 0 102 0 0.4 0 0.8 0.3 04/25/2005 22:00:00 11.6 0.5 12.6 10.3 11.4 0.5 12.6 9.9 0.4 0 0.4 0.4 132 2 130 305 102 0 102 0 0.4 0 0.8 0.3 04/25/2005 22:10:00 11.5 0.5 13 9.9 11.3 0.5 12.6 9.9 0.4 0 0.4 0.4 130 2 130 305 102 0 102 0 0.3 0 0.8 0.1 04/25/2005 22:20:00 11.6 0.5 12.6 10.3 11.5 0.5 12.6 9.9 0.4 0 0.4 0.4 132 2 130 305 102 0 101 0 0.3 0 0.6 0.1 04/25/2005 22:30:00 10.9 0.8 12.6 8.8 10.7 0.8 13 8.4 0.4 0 0.4 0.4 136 3 135 305 102 0 101 0 0.3 0 0.6 0.1 04/25/2005 22:40:00 7.5 1.5 10.3 3.8 7.8 1 10.3 4.9 0.4 0 0.4 0.4 154 12 140 305 102 0 102 0 0.3 0 0.8 0.3 04/25/2005 22:50:00 6.4 1.2 9.1 3.4 6.9 0.8 9.1 5.3 0.4 0 0.4 0.4 156 9 150 305 102 0 102 0 0.3 0 0.8 0.3 04/25/2005 23:00:00 7.1 1.6 9.9 3 7.3 1 9.1 4.6 0.4 0 0.4 0.4 154 9 152 305 102 0 101 0 0.3 0 0.8 0.3 04/25/2005 23:10:00 8.5 0.7 10.7 6.5 8.3 0.7 9.9 6.5 0.4 0 0.4 0.4 149 5 151 305 102 0 102 0 0.3 0 0.8 0.3 04/25/2005 23:20:00 10.7 0.7 11.8 8 10.5 0.6 11.8 7.6 0.4 0 0.4 0.4 143 3 144 305 102 0 102 0 0.3 0 0.6 0.1 04/25/2005 23:30:00 10.7 0.6 12.6 9.1 10.6 0.5 12.2 9.1 0.4 0 0.4 0.4 145 3 147 305 102 0 102 0 0.2 0 0.6 0.1 04/25/2005 23:40:00 10.8 0.5 12.2 9.1 10.7 0.5 11.5 8.4 0.4 0 0.4 0.4 143 3 141 305 102 0 102 0 0.2 0 0.6 0.1 04/25/2005 23:50:00 10.6 0.6 11.8 8.4 10.5 0.6 12.2 8.8 0.4 0 0.4 0.4 142 3 143 305 102 0 102 0 0.2 0.1 0.6 0.1 04/26/2005 00:00:00 9.6 0.6 11.1 8 9.5 0.6 10.7 8 0.4 0 0.4 0.4 142 2 140 305 102 0 101 0 0.2 0 0.6 0.1 04/26/2005 00:10:00 8.7 0.5 9.9 7.2 8.6 0.5 9.9 6.8 0.4 0 0.4 0.4 143 3 150 305 118 35 63 0 0.3 0.5 7.4 0.1 04/26/2005 00:20:00 9.3 0.7 10.7 7.6 9.2 0.7 10.7 6.8 0.4 0 0.4 0.4 138 3 137 305 105 8 105 0 0.3 0 0.8 0.1 04/26/2005 00:30:00 10.1 0.4 11.1 8.8 10.1 0.5 11.1 8.4 0.4 0.6 9.5 0.4 135 2 131 305 113 2 114 0 0.3 0 0.8 0.3 04/26/2005 00:40:00 10 0.4 11.1 8.8 10 0.4 11.1 8.4 0.4 0 0.4 0.4 135 2 135 305 114 3 122 0 0.3 0 0.8 0.3 04/26/2005 00:50:00 9.7 0.4 10.7 8.8 9.6 0.5 10.7 8 0.4 0 0.4 0.4 133 2 134 305 119 2 114 0 0.3 0 0.8 0.3 04/26/2005 01:00:00 10.1 0.4 11.1 8.8 10 0.4 11.1 8.8 0.4 0 0.4 0.4 134 2 138 305 123 1 124 0 0.3 0 0.8 0.3 04/26/2005 01:10:00 9.9 0.4 11.1 8.4 9.8 0.5 11.1 8.8 0.4 0 0.4 0.4 133 2 134 305 125 0 125 0 0.3 0 0.8 0.3 04/26/2005 01:20:00 9.3 0.4 10.3 8.4 9.3 0.5 10.3 8 0.4 0 0.4 0.4 133 0 133 305 126 0 126 0 0.3 0 0.8 0.3 04/26/2005 01:30:00 9.6 0.4 10.3 8.4 9.6 0.4 10.7 8.4 0.4 0 0.4 0.4 133 0 133 305 127 0 127 0 0.3 0 0.8 0.3 04/26/2005 01:40:00 8.9 0.6 10.3 7.2 8.9 0.6 10.3 7.2 0.4 0 0.4 0.4 133 0 133 305 128 0 128 0 0.3 0 0.6 0.3 04/26/2005 01:50:00 7.9 0.5 9.1 6.5 8 0.5 9.1 6.8 0.4 0 0.4 0.4 133 0 133 305 128 0 128 0 0.3 0 0.6 0.1 04/26/2005 02:00:00 7.4 0.6 8.8 5.7 7.7 0.5 9.1 5.7 0.4 0 0.4 0.4 133 0 133 305 129 0 129 0 0.2 0 0.6 0.1 04/26/2005 02:10:00 7.2 0.6 8.8 4.9 7.4 0.5 8.8 5.3 0.4 0 0.4 0.4 143 5 134 305 129 0 129 0 0.3 0 0.6 0.1 04/26/2005 02:20:00 6.5 1.9 9.9 2.6 6.9 1.5 9.9 4.6 0.4 0 0.4 0.4 147 11 133 305 129 0 129 0 0.6 0.2 1.3 0.3 04/26/2005 02:30:00 7.8 1.7 10.7 3 8 1 10.7 4.2 0.4 0 0.4 0.4 152 10 140 305 129 0 129 0 0.4 0 1 0.3 04/26/2005 02:40:00 7.8 2.2 11.1 3.8 8.7 1.1 11.1 6.1 0.4 0 0.4 0.4 157 13 147 305 130 0 129 0 0.3 0 0.8 0.1 04/26/2005 02:50:00 8.8 1 11.1 4.9 8.9 0.9 11.1 6.5 0.4 0 0.4 0.4 147 5 146 305 130 0 129 0 0.1 0.1 0.6 0.1 04/26/2005 03:00:00 7.9 1.4 10.3 3.4 7.9 1.2 10.3 4.9 0.4 0 0.4 0.4 145 8 138 305 131 1 130 0 0 0 0.6 -0.1 04/26/2005 03:10:00 9.3 0.8 10.7 6.8 9.1 0.8 11.1 6.5 0.4 0 0.4 0.4 139 1 138 305 133 0 133 0 -0.1 0 0.3 -0.4 04/26/2005 03:20:00 8.8 0.8 10.7 6.8 8.7 0.8 10.7 6.8 0.4 0 0.4 0.4 141 0 141 305 133 0 133 0 -0.1 0 0.3 -0.4 04/26/2005 03:30:00 8.7 0.7 11.1 6.5 8.7 0.7 10.7 5.3 0.4 0 0.4 0.4 144 4 149 305 134 0 134 0 -0.3 0 0.3 -0.4 04/26/2005 03:40:00 8.3 0.8 10.3 5.3 8.4 0.6 10.3 5.7 0.4 0 0.4 0.4 144 3 143 305 134 0 134 0 -0.3 0 0.3 -0.4 04/26/2005 03:50:00 6.5 1.4 9.5 3 7.2 0.8 9.1 4.6 0.4 0 0.4 0.4 156 4 152 305 134 0 134 0 -0.3 0 0.1 -0.4 04/26/2005 04:00:00 6 1.2 8 2.6 6.7 0.7 8.4 4.2 0.4 0 0.4 0.4 156 7 155 305 134 0 135 0 -0.3 0 0.3 -0.4 04/26/2005 04:10:00 6.6 2.1 10.3 2.6 7.4 1.2 9.9 5.3 0.4 0 0.4 0.4 159 12 142 305 135 0 135 0 0.1 0.1 0.8 -0.4 04/26/2005 04:20:00 8.8 1.3 11.8 4.2 8.7 1 11.1 5.7 0.4 0 0.4 0.4 142 8 138 305 135 0 135 0 -0.2 0 0.6 -0.4 04/26/2005 04:30:00 7.2 1.2 9.5 4.2 7.6 1 10.3 4.6 0.4 0 0.4 0.4 153 7 147 305 135 0 135 0 0 0 0.6 -0.1 04/26/2005 04:40:00 5.5 1.1 8 3 6.4 0.6 8 4.6 0.4 0 0.4 0.4 160 7 163 305 135 0 136 0 0.3 0.2 1.3 -0.1 04/26/2005 04:50:00 5.2 1 8.8 3 6.2 0.6 7.6 3.8 0.4 0 0.4 0.4 160 7 148 305 134 0 134 0 0.1 0.2 0.8 0.1 04/26/2005 05:00:00 5.8 1.5 8.4 2.3 6.5 0.8 8 4.2 0.4 0 0.4 0.4 156 11 146 305 134 0 134 0 0 0 0.6 -0.1 04/26/2005 05:10:00 7.7 0.8 9.9 5.7 7.5 0.9 9.5 5.7 0.4 0 0.4 0.4 141 3 138 305 134 0 133 0 -0.2 0 0.3 -0.4 04/26/2005 05:20:00 7.9 1.5 11.5 3.8 8.3 1.2 11.1 5.3 0.4 0 0.4 0.4 145 8 156 305 135 0 135 0 -0.2 0 0.3 -0.4 04/26/2005 05:30:00 7.1 1.1 9.9 4.2 7.4 1 10.7 4.9 0.4 0 0.4 0.4 141 10 151 305 135 1 136 0 0 0.2 0.6 -0.4 04/26/2005 05:40:00 8.1 0.7 10.7 4.6 7.7 0.7 9.5 5.7 0.4 0 0.4 0.4 147 5 151 305 133 0 133 0 0 0 0.6 -0.4 04/26/2005 05:50:00 8.8 0.8 10.7 6.8 8.5 0.8 9.9 6.5 0.4 0 0.4 0.4 145 3 147 305 132 0 131 0 -0.2 0 0.3 -0.4 04/26/2005 06:00:00 9.4 0.4 10.7 8 9.1 0.5 10.3 8 0.4 0 0.4 0.4 143 1 143 305 131 0 132 0 -0.3 0 0.3 -0.4 04/26/2005 06:10:00 8.9 0.5 10.3 7.6 8.6 0.5 9.9 7.2 0.4 0 0.4 0.4 140 2 138 305 130 0 131 0 -0.1 0 0.3 -0.4 04/26/2005 06:20:00 8.3 0.8 10.3 5.7 8.2 0.8 10.3 5.7 0.4 0 0.4 0.4 145 3 144 305 131 0 132 0 0 0 0.6 -0.1 04/26/2005 06:30:00 7.9 0.8 9.5 5.3 8 0.5 9.5 6.5 0.4 0 0.4 0.4 144 5 144 305 132 0 132 0 0 0 0.6 0.1 04/26/2005 06:40:00 8 0.6 9.5 5.3 7.8 0.6 8.8 6.1 0.4 0 0.4 0.4 146 2 148 305 132 0 132 0 0 0 0.1 0.1 04/26/2005 06:50:00 8.1 0.6 9.1 5.7 8.2 0.4 9.1 6.8 0.4 0 0.4 0.4 147 3 147 305 132 0 132 0 0 0 0.3 -0.1 04/26/2005 07:00:00 7.9 0.8 9.1 4.2 7.7 0.7 9.1 5.7 0.4 0 0.4 0.4 141 5 145 305 132 0 133 0 -0.1 0 0.3 -0.4 04/26/2005 07:10:00 7.2 1.1 9.1 2.6 7.3 0.7 8.8 4.2 0.4 0 0.4 0.4 144 7 142 305 133 0 132 0 -0.1 0 0.6 -0.1 04/26/2005 07:20:00 7.8 0.7 9.9 5.3 7.8 0.6 9.1 5.7 0.4 0 0.4 0.4 140 5 151 305 133 0 132 0 -0.1 0 0.6 -0.1 04/26/2005 07:30:00 6.8 1.5 8.8 1.9 7.4 1.1 8.8 1.5 0.4 0 0.4 0.4 146 9 146 305 132 0 133 0 0 0 0.6 -0.1 04/26/2005 07:40:00 6 1.5 8.8 2.3 6.5 1.1 9.1 3 0.4 0 0.4 0.4 148 12 147 305 132 0 132 0 0.2 0 0.8 0.1 04/26/2005 07:50:00 6.4 1.3 8.8 2.3 6.7 1.1 8.8 3.4 0.4 0 0.4 0.4 143 9 138 305 133 0 132 0 0.3 0 1 0.1 04/26/2005 08:00:00 5.3 1.7 7.6 0.4 5.8 1.4 8 1.9 0.4 0 0.4 0.4 140 15 143 305 133 0 133 0 0.6 0.1 1.3 0.3 04/26/2005 08:10:00 5.4 1.6 8 0.7 5.4 1.6 7.6 1.5 0.4 0 0.4 0.4 126 20 128 305 133 0 133 0 0.9 0.2 1.5 0.6 04/26/2005 08:20:00 2.4 1.7 6.5 0.4 2.8 1.5 6.5 0.4 0.4 0 0.4 0.4 90 49 131 305 133 1 133 0 1.4 0.1 1.5 1 04/26/2005 08:30:00 0.9 0.4 1.9 0.4 1.2 0.5 2.3 0.4 0.4 0 0.4 0.4 5 33 3 305 132 1 132 0 1.3 0.1 1.5 1.3 04/26/2005 08:40:00 0.6 0.5 1.9 0.4 0.9 0.7 2.3 0.4 0.4 0 0.4 0.4 3 53 350 305 132 2 131 0 1 0 1.5 1 04/26/2005 08:50:00 2.5 1.4 5.7 0.4 2.7 1.1 5.7 0.7 0.4 0 0.4 0.4 146 29 126 305 135 0 135 0 1.4 0 1.7 1 04/26/2005 09:00:00 4.8 1.2 7.2 2.3 4.7 1.1 7.2 2.3 0.4 0 0.4 0.4 147 13 137 305 134 0 135 0 0.9 0.3 1.5 0.6 04/26/2005 09:10:00 6 1 8.8 2.6 5.8 1.1 8.8 2.3 0.4 0 0.4 0.4 130 5 88 305 134 0 133 0 0.8 0.2 1.5 0.6 04/26/2005 09:20:00 1.1 1.1 4.9 0.4 1.1 0.8 4.2 0.4 0.4 0 0.4 0.4 352 69 112 305 133 2 135 0 1.6 0.2 2.2 1.3 04/26/2005 09:30:00 2.1 0.8 3.8 0.4 2.2 0.8 4.2 0.4 0.4 0 0.4 0.4 40 17 36 305 133 1 134 0 1.9 0.2 2.7 1.5 04/26/2005 09:40:00 3.8 3.2 9.5 0.4 3.6 3.1 9.5 0.4 0.4 0.1 1.5 0.4 93 58 136 305 129 1 128 0 2.2 0.3 3.2 1.5 04/26/2005 09:50:00 8.7 0.5 9.9 6.8 8.5 0.5 9.9 7.2 0.4 0 0.4 0.4 135 3 137 305 125 2 127 0 1.7 0.3 2.5 1.3 04/26/2005 10:00:00 8.7 0.4 9.5 7.6 8.6 0.4 9.5 7.6 0.4 0 0.4 0.4 131 3 134 305 122 0 122 0 1 0.1 1.5 0.8 04/26/2005 10:10:00 8.8 0.4 9.9 7.6 8.7 0.4 9.5 7.6 0.4 0 0.4 0.4 133 2 136 305 120 1 120 0 1 0.1 1.5 0.8 04/26/2005 10:20:00 9.4 0.4 9.9 8 9.1 0.4 9.9 7.2 0.4 0 0.4 0.4 135 2 136 305 119 1 119 0 1.2 0.1 1.5 0.8 04/26/2005 10:30:00 10.8 0.9 12.6 9.1 10.6 0.9 12.2 8.4 0.4 0 0.4 0.4 135 2 136 305 117 0 116 0 1 0 1.3 1 04/26/2005 10:40:00 11.6 0.4 12.2 10.3 11.3 0.5 12.2 9.9 0.4 0 0.4 0.4 134 2 136 305 116 0 116 0 1 0 1.5 0.8 04/26/2005 10:50:00 11 0.3 11.8 9.9 10.6 0.3 11.5 9.5 0.4 0 0.4 0.4 133 2 134 305 115 0 116 0 1.1 0 1.5 1 04/26/2005 11:00:00 10.9 0.4 11.8 9.1 10.5 0.4 11.5 8.8 0.4 0 0.4 0.4 134 2 133 305 115 0 115 0 1.3 0.1 2 1.3 04/26/2005 11:10:00 10 0.5 11.1 8.4 9.6 0.5 10.7 8 0.4 0 0.4 0.4 132 2 135 305 115 0 115 0 1.6 0.1 2.2 1.3 04/26/2005 11:20:00 9.6 0.5 10.7 8 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 129 4 133 305 115 0 115 0 1.9 0.1 2.5 1.5 04/26/2005 11:30:00 9.3 1 11.1 6.5 9.1 0.9 10.7 6.8 0.4 0 0.4 0.4 126 5 130 305 114 0 114 0 1.9 0.1 2.2 1.5 04/26/2005 11:40:00 10.6 0.5 11.5 8.8 10.4 0.5 11.8 8.8 0.4 0 0.4 0.4 129 3 130 305 114 0 114 0 1.6 0.1 2.2 1.3 04/26/2005 11:50:00 10.9 0.6 12.6 9.1 10.7 0.6 11.8 9.1 0.4 0 0.4 0.4 130 2 130 305 114 0 114 0 1.3 0.1 1.7 1.3 04/26/2005 12:00:00 11.1 0.5 12.2 9.9 10.8 0.5 11.8 9.5 0.4 0 0.4 0.4 131 3 130 305 114 0 114 0 1.3 0.2 1.7 1 04/26/2005 12:10:00 10.6 0.4 11.8 9.1 10.2 0.4 11.8 8.8 0.4 0 0.4 0.4 133 2 133 305 115 0 114 0 1.2 0.2 1.5 1 04/26/2005 12:20:00 9.8 0.6 11.1 8.4 9.5 0.7 11.1 8 0.4 0 0.4 0.4 133 2 137 305 115 0 115 0 1.3 0.2 2 1 04/26/2005 12:30:00 9.5 0.4 10.3 8 9.1 0.4 10.3 7.6 0.4 0 0.4 0.4 133 2 135 305 115 0 115 0 1.4 0 2 1.3 04/26/2005 12:40:00 10.6 0.8 12.2 8.4 10.2 0.9 12.2 8.4 0.4 0 0.4 0.4 133 3 129 305 114 0 114 0 1.6 0.2 2.2 1.5 04/26/2005 12:50:00 10.8 0.6 12.6 9.1 10.6 0.7 12.2 8.8 0.4 0 0.4 0.4 135 2 137 305 114 0 114 0 1.7 0.2 2.2 1.5 04/26/2005 13:00:00 11.7 0.5 13 9.9 11.5 0.5 12.6 9.9 0.4 0 0.4 0.4 133 2 133 305 114 0 113 0 1.6 0 2.2 1.3 04/26/2005 13:10:00 11.2 0.4 12.2 9.9 11 0.5 11.8 9.1 0.4 0 0.4 0.4 133 2 134 305 113 0 113 0 1.4 0.1 2 1.3 04/26/2005 13:20:00 9.9 0.6 11.5 7.6 9.9 0.6 11.5 7.6 0.4 0 0.4 0.4 127 4 132 305 113 0 113 0 2 0.3 2.7 1.3 04/26/2005 13:30:00 8.9 1 10.7 6.5 9 1 10.7 6.8 0.4 0 0.4 0.4 123 7 129 305 113 0 113 0 2.5 0 3.2 2.2 04/26/2005 13:40:00 8.4 1.1 10.7 4.9 8.4 1 10.3 5.3 0.4 0 0.4 0.4 118 7 112 305 113 0 114 0 2.9 0.2 3.7 2.7 04/26/2005 13:50:00 7.5 0.9 9.5 5.7 7.6 0.8 9.5 5.3 0.4 0 0.4 0.4 114 6 112 305 114 0 114 0 3.5 0.1 3.9 3.2 04/26/2005 14:00:00 8.4 1 10.3 5.7 8.5 1 10.7 5.7 0.4 0 0.4 0.4 119 6 118 305 114 0 114 0 3.4 0.1 3.9 3.2 04/26/2005 14:10:00 6.6 1 8.4 4.2 6.7 1 9.1 4.2 0.4 0 0.4 0.4 110 8 116 305 115 0 116 0 3.7 0.1 4.2 3.4 04/26/2005 14:20:00 6.9 0.8 8.8 4.9 7.1 0.7 8.8 4.9 0.4 0 0.4 0.4 115 8 120 305 117 1 117 0 3.7 0 4.4 3.4 04/26/2005 14:30:00 6 0.8 8 3.8 6 0.7 8 4.2 0.4 0 0.4 0.4 98 9 114 305 120 1 119 0 3.3 0.2 4.2 2.9 04/26/2005 14:40:00 5.5 0.6 7.2 4.2 5.4 0.6 7.2 4.2 0.4 0 0.4 0.4 96 8 88 305 122 0 121 0 2.8 0.2 3.4 2.7 04/26/2005 14:50:00 5.7 0.8 8 3.8 5.6 0.7 7.6 4.2 0.4 0 0.4 0.4 92 9 87 305 123 0 123 0 3.5 0.2 4.2 2.9 04/26/2005 15:00:00 5.9 0.6 7.6 4.2 5.8 0.7 8 4.2 0.4 0 0.4 0.4 91 8 89 305 124 0 124 0 3.6 0.1 4.2 3.4 04/26/2005 15:10:00 6.7 0.7 8.8 4.9 6.5 0.5 8 4.9 0.4 0 0.4 0.4 94 5 96 305 125 0 125 0 3.3 0.2 3.9 2.9 04/26/2005 15:20:00 7.2 0.5 8.4 5.3 7 0.5 8.4 5.7 0.4 0 0.4 0.4 93 6 89 305 126 1 125 0 3.3 0.3 3.9 2.7 04/26/2005 15:30:00 6.7 0.6 8 4.6 6.6 0.6 8.4 4.9 0.4 0 0.4 0.4 96 7 99 305 128 1 128 0 2.9 0.3 4.2 2.5 04/26/2005 15:40:00 6.5 0.6 8 4.9 6.4 0.5 8 4.6 0.4 0 0.4 0.4 95 6 94 305 131 0 130 0 3.6 0.2 4.2 3.2 04/26/2005 15:50:00 6.1 0.6 7.2 4.9 6 0.5 7.2 4.9 0.4 0 0.4 0.4 96 7 85 305 131 0 131 0 3.6 0.2 4.2 3.4 04/26/2005 16:00:00 7.2 0.7 8.8 4.9 6.9 0.7 8.4 4.9 0.4 0 0.4 0.4 100 6 102 305 131 2 129 0 3.3 0.2 3.9 2.7 04/26/2005 16:10:00 6.7 1 8.4 4.2 6.7 0.9 8.8 4.2 0.4 0 0.4 0.4 105 7 110 305 130 1 129 0 2.8 0.1 3.2 2.5 04/26/2005 16:20:00 4.8 1.2 7.6 1.1 4.7 1 7.2 2.3 0.4 0 0.4 0.4 99 14 112 305 131 0 131 0 2.8 0.1 3.2 2.5 04/26/2005 16:30:00 4.8 0.9 7.2 3 4.6 0.7 6.8 3 0.4 0 0.4 0.4 92 12 73 305 131 0 131 0 2.5 0.2 3.2 2.2 04/26/2005 16:40:00 4.1 1.2 6.8 1.5 3.9 1.3 7.2 1.5 0.4 0 0.4 0.4 86 17 66 305 131 1 130 0 1.9 0.2 2.7 1.5 04/26/2005 16:50:00 3.3 1 5.3 1.1 3.2 1 4.9 1.1 0.4 0 0.4 0.4 76 19 83 305 132 0 132 0 2.2 0.2 2.9 2 04/26/2005 17:00:00 4.3 0.8 6.5 2.6 4 0.7 6.1 2.6 0.4 0 0.4 0.4 97 11 92 305 132 0 132 0 2.8 0.2 3.4 2.5 04/26/2005 17:10:00 4.1 1 6.1 1.5 4 1 6.1 0.4 0.4 0 0.4 0.4 103 13 108 305 132 0 132 0 2.9 0.2 3.4 2.7 04/26/2005 17:20:00 3.5 1.2 6.5 0.4 3.5 1.1 6.1 1.1 0.4 0 0.4 0.4 107 21 112 305 134 1 135 0 3.2 0.2 3.9 2.9 04/26/2005 17:30:00 2.6 1 5.3 0.4 2.8 0.8 5.3 1.1 0.4 0 0.4 0.4 86 21 97 305 134 0 135 0 3.4 0.2 4.2 3.2 04/26/2005 17:40:00 3.8 1 6.5 0.7 3.7 0.9 6.5 0.7 0.4 0 0.4 0.4 96 17 126 305 134 0 133 0 3.4 0.2 3.7 3.2 04/26/2005 17:50:00 3.4 0.8 5.3 1.5 3.3 0.8 4.9 1.5 0.4 0 0.4 0.4 85 17 79 305 134 0 134 0 3.4 0.2 3.7 3.2 04/26/2005 18:00:00 4 1.2 7.2 1.1 3.9 1.2 7.2 0.7 0.4 0 0.4 0.4 80 17 95 305 134 0 134 0 3.3 0.1 3.7 2.9 04/26/2005 18:10:00 4.4 0.8 7.2 1.9 4.3 0.9 6.8 2.6 0.4 0 0.4 0.4 77 17 77 305 134 0 135 0 3.3 0 3.7 3.2 04/26/2005 18:20:00 5 1.3 9.1 2.3 4.9 1.2 8 2.3 0.4 0 0.4 0.4 85 15 90 305 133 0 133 0 3.4 0.1 3.9 3.2 04/26/2005 18:30:00 6.5 1.1 8.8 3 6.1 1 8.8 3.4 0.4 0 0.4 0.4 92 8 88 305 133 0 133 0 3.1 0.1 3.7 2.9 04/26/2005 18:40:00 6.6 0.6 8.4 4.6 6.4 0.6 8 4.6 0.4 0 0.4 0.4 93 8 85 305 133 0 133 0 3.3 0.1 3.7 2.9 04/26/2005 18:50:00 7.7 0.9 9.9 4.6 7.4 0.8 9.1 5.3 0.4 0 0.4 0.4 94 6 98 305 133 0 133 0 2.9 0.2 3.7 2.7 04/26/2005 19:00:00 8.9 1 11.1 5.7 8.7 0.9 10.7 6.5 0.4 0 0.4 0.4 93 7 93 305 134 0 134 0 3.3 0.2 3.9 2.9 04/26/2005 19:10:00 9.4 1.1 11.8 6.1 9 1 11.1 6.5 0.4 0 0.4 0.4 96 7 90 305 134 0 134 0 3.1 0.2 3.7 2.7 04/26/2005 19:20:00 9.2 1.2 11.8 5.7 8.7 1 11.1 5.7 0.4 0 0.4 0.4 97 8 84 305 135 0 135 0 2.7 0.1 3.2 2.5 04/26/2005 19:30:00 8.8 1.3 11.5 5.7 8.5 1.1 11.5 6.1 0.4 0 0.4 0.4 94 9 90 305 135 0 135 0 2.6 0 3.2 2.5 04/26/2005 19:40:00 10 1.3 13.7 6.1 9.5 1.3 14.1 6.1 0.4 0 0.4 0.4 89 10 71 305 134 0 135 0 2.6 0 3.2 2.5 04/26/2005 19:50:00 10.1 1.3 14.5 7.2 9.6 1.3 13.7 6.5 0.4 0 0.4 0.4 91 9 87 305 134 0 135 0 2.6 0.1 3.2 2.5 04/26/2005 20:00:00 10.5 1.4 14.9 6.1 9.9 1.4 14.1 5.7 0.4 0 0.4 0.4 87 8 78 305 134 0 135 0 2.7 0 3.2 2.5 04/26/2005 20:10:00 11.6 1.4 14.9 8 11 1.5 15.3 7.2 0.4 0 0.4 0.4 88 8 90 305 134 0 134 0 2.6 0 3.2 2.5 04/26/2005 20:20:00 10.6 1.4 14.5 7.2 10 1.5 16.4 6.1 0.4 0 0.4 0.4 87 8 84 305 134 0 134 0 2.3 0.1 2.9 2.2 04/26/2005 20:30:00 10.2 1.3 14.5 7.2 9.6 1.3 13.3 6.5 0.4 0 0.4 0.4 85 9 79 305 133 0 133 0 2.2 0 2.5 2 04/26/2005 20:40:00 10.2 1.3 13.3 6.8 9.8 1.2 13.3 7.2 0.4 0 0.4 0.4 85 9 94 305 133 0 133 0 2 0 2.5 2 04/26/2005 20:50:00 9.9 1.5 14.1 6.5 9.3 1.6 14.1 5.7 0.4 0 0.4 0.4 87 12 82 305 133 0 133 0 2 0 2.5 2 04/26/2005 21:00:00 10.6 1.7 16.1 5.7 10 1.7 14.5 5.7 0.4 0 0.4 0.4 89 11 106 305 132 0 132 0 2.2 0.1 2.7 2 04/26/2005 21:10:00 10 2 15.3 4.9 9.4 2 14.9 3.8 0.4 0 0.4 0.4 87 12 90 305 132 0 132 0 2.3 0.2 3.2 2.2 04/26/2005 21:20:00 10 1.7 14.5 5.7 9.5 1.6 14.1 5.7 0.4 0 0.4 0.4 86 10 86 305 131 0 131 0 2.3 0.2 3.2 2 04/26/2005 21:30:00 9.7 1.5 14.5 6.1 9.2 1.5 15.3 6.1 0.4 0 0.4 0.4 83 10 71 305 130 0 130 0 2 0.1 2.5 1.7 04/26/2005 21:40:00 10.3 1.2 14.9 7.2 9.9 1.3 14.5 6.8 0.4 0 0.4 0.4 82 8 95 305 131 0 131 0 1.9 0.1 2.5 1.7 04/26/2005 21:50:00 10.2 1.2 13.7 7.6 9.9 1.3 14.5 6.8 0.4 0 0.4 0.4 82 9 68 305 131 0 131 0 2.1 0 2.5 2 04/26/2005 22:00:00 10.4 1.3 14.1 7.2 9.9 1.3 14.1 6.8 0.4 0 0.4 0.4 84 9 85 305 130 0 131 0 2 0.1 2.5 2 04/26/2005 22:10:00 10.6 1.1 13.3 8 10.1 1.1 13 7.6 0.4 0 0.4 0.4 80 8 82 305 131 0 131 0 2 0.1 2.5 1.7 04/26/2005 22:20:00 10.4 1.3 14.1 7.6 10.1 1.2 14.9 7.6 0.4 0 0.4 0.4 80 7 75 305 130 0 130 0 1.9 0.1 2.5 1.7 04/26/2005 22:30:00 11.9 1.3 15.6 8.8 11.3 1.2 15.6 8.4 0.4 0 0.4 0.4 79 8 81 305 131 0 131 0 2.2 0.1 2.7 2 04/26/2005 22:40:00 12.4 1.2 17.2 9.9 11.9 1.2 16.4 9.1 0.4 0 0.4 0.4 75 6 82 305 130 0 131 0 1.9 0.2 2.5 1.5 04/26/2005 22:50:00 11.4 1.1 14.5 8.8 10.6 1 13.3 8 0.4 0 0.4 0.4 73 5 62 305 129 0 128 0 1 0.2 2 0.8 04/26/2005 23:00:00 12.4 0.9 15.3 9.9 11.7 0.9 15.3 9.5 0.4 0 0.4 0.4 71 5 74 305 128 0 128 0 1 0.1 1.5 0.6 04/26/2005 23:10:00 11.3 0.9 13.7 8.8 10.9 0.9 13.3 8 0.4 0 0.4 0.4 66 5 69 305 128 0 128 0 0.6 0.1 1 0.6 04/26/2005 23:20:00 9.6 1 12.6 7.2 9.1 1 12.2 6.8 0.4 0 0.4 0.4 62 6 56 305 127 0 128 0 0.5 0 1 0.3 04/26/2005 23:30:00 8 0.9 11.1 5.7 7.6 0.9 10.3 5.3 0.4 0 0.4 0.4 58 7 70 305 126 0 127 0 0.3 0.1 0.8 0.1 04/26/2005 23:40:00 7.6 0.7 10.3 5.7 7.3 0.8 9.1 5.3 0.4 0 0.4 0.4 56 8 69 305 127 0 127 0 0.2 0.1 0.6 0.1 04/26/2005 23:50:00 8 0.9 10.3 6.1 7.7 1 10.3 5.7 0.4 0 0.4 0.4 58 8 61 305 127 0 127 0 0.1 0.1 0.6 0.1 04/27/2005 00:00:00 9.1 0.9 11.1 6.8 8.7 0.9 11.1 6.5 0.4 0 0.4 0.4 62 6 64 305 126 0 126 0 0.2 0.2 0.8 0.1 04/27/2005 00:10:00 9.7 0.8 12.2 7.6 9.3 0.9 11.5 7.2 0.4 0 0.4 0.4 61 6 62 305 125 0 126 0 0.3 0.1 1 0.1 04/27/2005 00:20:00 9.4 1 12.2 6.8 9 1 11.1 6.5 0.4 0 0.4 0.4 60 7 59 305 124 1 125 0 0.4 0.1 1 0.1 04/27/2005 00:30:00 9.8 1 12.6 7.6 9.3 1.1 12.2 6.8 0.4 0 0.4 0.4 62 6 62 305 122 1 122 0 0.3 0.1 0.8 0.1 04/27/2005 00:40:00 9.2 0.9 11.5 6.8 8.7 0.9 11.5 6.8 0.4 0 0.4 0.4 60 8 59 305 121 1 121 0 0.2 0.2 0.8 0.1 04/27/2005 00:50:00 8.7 1 11.5 6.1 8.4 1.1 11.1 6.1 0.4 0 0.4 0.4 60 7 58 305 124 0 125 0 0.1 0.1 0.6 0.1 04/27/2005 01:00:00 7.6 0.8 9.5 5.7 7.2 0.8 9.1 5.3 0.4 0 0.4 0.4 57 5 54 305 124 0 124 0 0 0 0.6 -0.1 04/27/2005 01:10:00 7.6 0.9 11.1 6.1 7.3 0.9 9.9 5.3 0.4 0 0.4 0.4 56 7 63 305 123 0 123 0 0 0 0.3 -0.1 04/27/2005 01:20:00 8 0.8 10.3 5.7 7.7 0.9 9.9 5.7 0.4 0 0.4 0.4 56 7 57 305 123 0 122 0 0.1 0.1 0.6 0.1 04/27/2005 01:30:00 9.8 1.3 11.8 6.8 9.5 1.2 11.8 6.1 0.4 0 0.4 0.4 63 6 71 305 124 0 124 0 0.2 0.1 0.6 0.1 04/27/2005 01:40:00 12.2 0.8 14.1 9.9 11.7 0.9 14.1 9.5 0.4 0 0.4 0.4 67 3 63 305 123 0 122 0 0.3 0 0.8 0.1 04/27/2005 01:50:00 12.6 0.8 14.5 10.7 12.4 0.8 14.5 9.9 0.4 0 0.4 0.4 67 4 66 305 122 1 123 0 0.5 0 0.8 0.3 04/27/2005 02:00:00 11.8 0.7 13.7 9.5 11.7 0.7 13.3 9.5 0.4 0 0.4 0.4 69 4 68 305 122 1 122 0 0.5 0 0.8 0.3 04/27/2005 02:10:00 11.1 0.8 13.3 9.1 10.9 0.9 13 8.8 0.4 0 0.4 0.4 70 4 67 305 121 0 121 0 0.5 0 0.8 0.3 04/27/2005 02:20:00 11.3 0.7 13 9.1 11.2 0.8 13.3 9.1 4.2 5.1 12.2 0.4 70 4 76 305 117 7 120 0 0.5 0 1 0.6 04/27/2005 02:30:00 11 1 14.1 8.8 10.9 1.1 14.1 8 10.7 1.7 14.1 0.4 72 5 75 305 118 2 120 0 0.6 0.1 1 0.6 04/27/2005 02:40:00 11.3 1.2 15.6 8 11 1.3 16.1 7.6 11 1.3 16.1 7.6 73 7 65 305 120 0 120 0 0.9 0 1.3 0.6 04/27/2005 02:50:00 11.5 1.1 15.6 8.8 11.3 1.1 14.1 8.4 11.3 1.1 14.1 8.4 73 6 66 305 120 0 120 0 1 0 1.5 0.8 04/27/2005 03:00:00 11.3 1 14.1 8.4 11.1 1.1 14.1 8.4 11.1 1.1 14.1 8.4 74 6 74 305 120 0 120 0 1 0 1.5 0.8 04/27/2005 03:10:00 10.7 0.9 13 8 10.7 0.9 13.3 8 10.7 0.9 13.3 8 73 6 68 305 121 1 121 0 0.7 0.1 1.3 0.6 04/27/2005 03:20:00 10.6 0.7 13 8.8 10.5 0.7 13 8.8 10.5 0.7 13 8.8 74 4 74 305 122 0 122 0 0.7 0.1 1 0.6 04/27/2005 03:30:00 10.9 1 14.1 8 10.7 1 13.3 8 10.7 1 13.3 8 76 6 70 305 122 1 121 0 0.9 0 1.3 0.6 04/27/2005 03:40:00 10.4 1.2 15.3 6.8 10.2 1.2 13.3 6.5 10.2 1.2 13.3 6.5 77 9 90 305 122 0 122 0 1.1 0 1.5 1 04/27/2005 03:50:00 10.7 1.1 14.1 8 10.6 1.2 13.7 8.4 10.6 1.2 13.7 8.4 77 8 80 305 122 0 122 0 1.4 0 2 1.3 04/27/2005 04:00:00 11 1.1 14.1 8.4 10.7 1.1 14.1 8 10.7 1.1 14.1 8 78 8 80 305 122 0 122 0 1.6 0 2 1.3 04/27/2005 04:10:00 11.1 1.2 14.5 7.6 10.7 1.3 14.9 8 10.7 1.3 14.9 8 78 8 70 305 122 0 122 0 1.6 0 2 1.5 04/27/2005 04:20:00 10.1 1.5 17.6 6.5 9.8 1.5 15.3 6.1 9.8 1.5 15.3 6.1 73 9 78 305 121 0 121 0 1.3 0.1 2 1 04/27/2005 04:30:00 9.8 1.7 14.1 6.1 9.6 1.7 15.3 6.1 9.6 1.7 15.3 6.1 72 11 90 305 121 0 121 0 1.3 0.2 1.7 1 04/27/2005 04:40:00 10 2.2 16.8 4.6 9.7 2.3 15.3 4.6 9.7 2.3 15.6 4.6 69 13 74 305 121 0 121 0 1.3 0.1 2 1.3 04/27/2005 04:50:00 8.4 2.1 14.5 4.2 8.2 2.3 13.3 4.2 8.2 2.3 13.3 4.2 77 19 48 305 121 0 121 0 1.5 0 2 1.3 04/27/2005 05:00:00 8.5 2.2 15.6 3.8 8.1 2.3 14.5 3.8 8.1 2.3 14.5 3.4 80 21 70 305 121 0 121 0 1.7 0.1 2.2 1.5 04/27/2005 05:10:00 7.4 1.9 14.5 3.4 7.2 1.8 12.2 2.6 7.2 1.8 12.2 1.9 80 22 92 305 121 0 121 0 1.7 0.1 2.2 1.5 04/27/2005 05:20:00 8.2 2.3 14.1 3.4 7.9 2.4 14.5 3.4 7.9 2.4 14.5 3 78 20 67 305 120 0 120 0 1.7 0.1 2.5 1.5 04/27/2005 05:30:00 9.2 2.4 16.4 4.6 8.8 2.6 16.4 4.2 8.8 2.6 16.4 4.2 73 18 75 305 119 0 119 0 1.6 0 2.2 1.5 04/27/2005 05:40:00 8.8 2.3 17.2 4.2 8.4 2.5 17.2 3 8.4 2.5 17.2 3 72 18 60 305 119 0 118 0 1.7 0.1 2.2 1.5 04/27/2005 05:50:00 9.1 2.1 14.5 4.9 9 2.5 14.9 3.8 9 2.5 14.9 3.4 71 18 80 305 118 0 118 0 1.7 0.1 2.2 1.5 04/27/2005 06:00:00 8.8 2.3 14.1 3.4 8.6 2.4 14.1 3.4 8.6 2.4 14.1 1.5 69 15 64 305 118 0 118 0 1.7 0.1 2.2 1.5 04/27/2005 06:10:00 8.4 2.1 14.1 4.2 7.9 2.2 14.1 2.6 7.9 2.4 14.1 0.4 76 22 105 305 118 0 118 0 1.8 0.2 2.5 1.5 04/27/2005 06:20:00 5.5 2.3 9.9 0.4 5.1 1.9 10.3 0.7 3.9 3.1 10.3 0.4 97 30 106 305 116 1 118 0 2 0.2 2.5 1.7 04/27/2005 06:30:00 7.4 2 12.2 2.6 7.1 1.9 11.8 2.6 6.6 2.7 11.8 0.4 101 23 134 305 116 1 117 0 2.2 0.2 2.7 2 04/27/2005 06:40:00 7.2 2 13 1.9 6.6 1.8 11.8 3 5.9 2.8 11.8 0.4 102 21 74 305 116 1 115 0 2.2 0.2 2.7 2.2 04/27/2005 06:50:00 7.2 1.7 13.3 3 6.7 1.6 11.1 2.6 6 2.6 11.1 0.4 102 18 105 305 116 0 116 0 2.2 0.1 2.7 2 04/27/2005 07:00:00 6.2 1.6 9.9 1.5 5.8 1.5 10.3 1.5 4.6 2.7 10.3 0.4 107 22 156 305 115 1 117 0 2.2 0 2.7 2 04/27/2005 07:10:00 7.9 2 14.1 3 7.5 1.9 15.3 3.4 7.1 2.6 15.3 0.4 108 18 119 305 116 0 116 0 2.3 0.2 2.7 2.2 04/27/2005 07:20:00 8.3 1.9 15.6 4.6 7.7 1.9 14.1 3.8 7.5 2.4 14.1 0.4 109 15 108 305 116 0 115 0 2.3 0.2 2.7 2.2 04/27/2005 07:30:00 9.7 2.2 16.1 4.9 9.2 2.3 15.6 4.6 9.2 2.4 15.6 0.4 120 13 136 305 116 0 116 0 2.5 0.2 2.9 2.2 04/27/2005 07:40:00 10.6 1.7 15.3 6.5 10.1 1.6 14.1 6.5 10.1 1.6 14.1 5.7 124 12 121 305 116 0 116 0 2.5 0.1 2.9 2.5 04/27/2005 07:50:00 11 1.8 16.1 6.8 10.6 1.8 15.3 6.1 10.6 1.8 15.3 5.7 122 12 127 305 115 0 115 0 2.4 0.1 2.9 2.2 04/27/2005 08:00:00 11.2 2.2 17.2 5.7 10.9 2.2 16.8 6.1 10.9 2.3 16.8 3.8 121 14 129 305 115 0 115 0 2.3 0.1 2.7 2.2 04/27/2005 08:10:00 11.8 2.2 17.9 6.8 11.2 2.1 17.6 6.5 11.2 2.2 17.6 5.3 122 12 120 305 115 0 115 0 2.3 0.2 2.7 2.2 04/27/2005 08:20:00 11.1 1.9 16.8 6.1 10.9 1.9 16.8 6.1 10.8 2.1 16.8 2.6 125 13 123 305 104 3 103 0 2.2 0.1 2.7 2 04/27/2005 08:30:00 10.9 1.6 16.1 7.2 10.5 1.7 16.1 6.8 10.5 1.8 16.1 4.6 128 13 146 305 104 1 104 0 2.2 0.1 2.5 2 04/27/2005 08:40:00 11.5 1.7 17.2 6.1 11.2 1.7 15.3 6.8 11.2 1.8 15.3 5.3 132 11 144 305 105 0 105 0 2.2 0.1 2.7 2 04/27/2005 08:50:00 11 1.7 16.1 6.1 10.7 1.7 14.5 6.5 10.6 2 14.5 2.6 130 13 143 305 104 0 105 0 2.2 0.1 2.7 2 04/27/2005 09:00:00 11 1.6 16.1 7.2 10.5 1.6 15.3 5.7 10.4 1.8 15.3 0.4 128 13 139 305 104 1 104 0 2.2 0.1 2.7 2 04/27/2005 09:10:00 11.7 1.5 16.1 7.6 11.3 1.7 16.1 6.8 11.3 1.7 16.1 5.3 130 11 140 305 105 0 105 0 2.2 0 2.7 2 04/27/2005 09:20:00 10.9 1.8 15.3 6.5 10.5 1.7 15.3 6.1 10.5 1.8 15.3 6.1 127 13 140 305 105 0 105 0 2.2 0.1 2.7 2 04/27/2005 09:30:00 11.4 1.8 16.8 7.2 11.1 1.7 16.1 7.2 11.1 1.7 16.1 7.2 127 15 116 305 105 0 105 0 2.1 0.1 2.7 2 04/27/2005 09:40:00 11.5 1.8 16.8 7.2 11.1 1.9 17.2 7.2 11.1 1.9 17.2 7.2 132 12 148 305 105 0 106 0 2.2 0.1 2.7 2 04/27/2005 09:50:00 11 1.9 16.8 5.7 10.8 1.9 17.6 6.5 10.8 1.9 17.6 6.5 132 15 143 305 104 0 105 0 2.2 0.1 2.7 2 04/27/2005 10:00:00 11.9 1.9 16.8 6.1 11.5 1.9 16.1 6.5 11.5 2 16.1 6.1 131 12 116 305 104 0 104 0 2.2 0.1 2.7 2.2 04/27/2005 10:10:00 13.5 1.2 16.8 10.3 13.1 1.2 16.8 9.5 13.1 1.2 16.8 9.5 132 7 138 305 104 0 104 0 2.2 0.1 2.7 2.2 04/27/2005 10:20:00 13.8 1.2 17.2 10.3 13.3 1.2 17.2 10.3 13.3 1.2 17.2 10.3 132 5 133 305 104 0 105 0 2.2 0.1 2.7 2.2 04/27/2005 10:30:00 14.1 1.3 17.2 9.9 13.6 1.2 16.8 9.5 13.6 1.2 16.8 9.5 132 6 135 305 105 0 106 0 2.2 0.1 2.7 2.2 04/27/2005 10:40:00 14 1.1 16.4 10.7 13.6 1.1 16.1 10.7 13.6 1.1 16.1 10.7 131 5 125 305 105 0 105 0 2.2 0.1 2.7 2.2 04/27/2005 10:50:00 13.8 1.1 16.8 11.1 13.5 1.1 16.8 10.3 13.5 1.1 16.8 10.3 132 5 146 305 105 0 105 0 2.2 0 2.5 2 04/27/2005 11:00:00 13.8 0.8 15.6 11.1 13.5 0.9 15.6 11.1 13.5 0.9 15.6 11.1 133 5 131 305 105 0 105 0 2.1 0.1 2.5 2 04/27/2005 11:10:00 13.9 1 16.1 9.9 13.4 1 15.3 10.3 13.4 1 15.3 10.3 131 4 135 305 102 2 103 0 2.1 0.1 2.5 2 04/27/2005 11:20:00 13.9 1.1 16.4 10.7 13.4 1.1 16.4 10.7 13.4 1.1 16.4 10.7 132 5 137 305 100 0 100 0 2 0.1 2.5 2 04/27/2005 11:30:00 14.5 1 16.8 11.8 14.1 1 16.4 11.5 14.1 1 16.4 11.5 131 5 126 305 100 0 100 0 2 0.1 2.5 2 04/27/2005 11:40:00 14.1 1 16.1 11.8 13.7 1 16.1 10.7 13.7 1 16.1 10.7 132 5 132 305 99 0 99 0 2 0.1 2.5 2 04/27/2005 11:50:00 14.5 1 17.6 11.8 14.1 1 17.6 10.7 14.1 1 17.6 10.7 130 5 126 305 99 0 99 0 2.1 0.1 2.7 2 04/27/2005 12:00:00 14.4 1.1 17.2 10.7 13.9 1.2 16.8 10.7 13.9 1.2 16.8 10.3 131 5 132 305 98 0 98 0 2.1 0 2.5 2 04/27/2005 12:10:00 14 1.1 17.2 10.7 13.5 1.2 17.2 10.7 13.5 1.2 17.2 10.7 131 5 131 305 98 0 98 0 2 0.1 2.5 2 04/27/2005 12:20:00 13.3 1.4 17.2 9.5 12.9 1.3 16.8 8.8 12.9 1.4 16.8 8 128 8 126 305 97 0 98 0 2 0.1 2.5 2 04/27/2005 12:30:00 12.4 1.5 16.1 7.2 12 1.4 14.9 6.8 12 1.6 14.9 2.6 128 7 131 305 96 0 97 0 2 0 2.5 2 04/27/2005 12:40:00 12.4 1.5 17.6 8.8 12.2 1.5 17.2 8.4 12.2 1.6 17.2 7.6 133 11 127 305 96 0 96 0 2 0 2.5 1.7 04/27/2005 12:50:00 11.4 1.5 16.1 7.6 11 1.5 16.4 7.2 10.8 1.7 16.4 5.7 132 12 154 305 97 0 97 0 2 0.1 2.5 2 04/27/2005 13:00:00 10.8 1.7 16.8 6.8 10.4 1.7 16.8 6.8 10.2 1.9 16.4 4.9 131 14 146 305 97 0 97 0 2 0.1 2.5 2 04/27/2005 13:10:00 10.6 1.6 15.3 6.1 10.2 1.6 14.5 6.1 9.9 1.9 14.5 1.9 129 13 140 305 96 0 96 0 1.9 0.1 2.5 1.7 04/27/2005 13:20:00 10.2 1.6 15.3 6.1 9.9 1.6 15.3 4.9 9.5 2 15.3 0.4 129 13 120 305 96 0 96 0 1.9 0.1 2.5 1.5 04/27/2005 13:30:00 10.9 1.8 17.6 6.5 10.5 1.7 17.2 6.5 10.2 2 17.2 3 134 12 146 305 96 0 97 0 2 0.1 2.7 1.7 04/27/2005 13:40:00 10 1.6 14.1 5.7 9.6 1.7 13.7 5.7 9.3 2.1 13.7 1.1 128 13 121 305 95 1 94 0 2.2 0.1 2.7 2 04/27/2005 13:50:00 9.7 2 14.9 4.6 9.2 2 14.9 4.9 8.5 2.8 14.9 0.4 123 16 135 305 94 1 94 0 2.2 0.1 2.7 2 04/27/2005 14:00:00 10.2 2 17.9 5.3 9.9 1.9 16.4 4.6 9.5 2.4 16.4 0.4 127 17 114 305 93 1 92 0 2.3 0.1 2.7 2.2 04/27/2005 14:10:00 10.8 2.4 18.3 5.7 10.5 2.4 18.7 5.3 10 3.1 18.7 0.4 123 16 132 305 92 1 92 0 2.2 0.1 2.7 2 04/27/2005 14:20:00 10.1 2.5 16.8 4.6 9.5 2.5 16.4 4.6 8.4 3.8 16.4 0.4 126 17 113 305 90 1 90 0 2.3 0.2 2.9 2.2 04/27/2005 14:30:00 10.7 2.6 17.2 6.1 10.3 2.5 17.6 5.3 9.4 3.5 17.6 0.4 124 15 116 305 87 1 88 0 2.2 0.1 2.7 2.2 04/27/2005 14:40:00 10 2.2 15.3 4.6 9.6 2.2 15.3 3.8 8.3 3.5 15.3 0.4 123 16 118 305 85 1 86 0 2.2 0.1 2.7 2.2 04/27/2005 14:50:00 12.1 2.4 18.3 6.5 11.5 2.3 17.2 6.8 11.1 2.8 17.2 1.9 123 13 113 305 83 0 83 0 2.2 0.1 2.7 2 04/27/2005 15:00:00 11.9 2.1 17.6 7.2 11.5 2.2 17.2 6.8 10.7 2.9 17.2 1.5 123 15 127 305 83 0 83 0 2.1 0 2.5 2 04/27/2005 15:10:00 12.1 2.1 17.6 7.6 11.6 2.1 17.6 6.8 10.8 2.8 17.6 0.4 122 14 141 305 84 1 83 0 2 0.1 2.5 2 04/27/2005 15:20:00 12.5 2.3 18.3 6.5 12.1 2.4 18.7 5.7 11.3 3.1 18.3 0.4 122 12 154 305 85 0 86 0 2 0.1 2.5 2 04/27/2005 15:30:00 13.1 2.2 19.5 8.4 12.7 2.3 19.9 8 0.4 0 0.4 0.4 121 12 124 305 86 0 86 0 1.9 0.1 2.5 1.7 04/27/2005 15:40:00 13.8 2.1 18.7 9.5 13.4 2.1 18.7 8.8 0.4 0 0.4 0.4 123 11 133 305 86 0 86 0 1.8 0.2 2.2 1.5 04/27/2005 15:50:00 13.9 1.8 18.3 8.8 13.5 2 18.3 8 0.4 0 0.4 0.4 120 12 121 305 89 1 90 0 1.7 0.2 2.2 1.5 04/27/2005 16:00:00 12.8 2.3 17.9 8 12.4 2.3 18.7 7.2 0.4 0 0.4 0.4 121 12 113 305 90 0 90 0 1.7 0.1 2.2 1.5 04/27/2005 16:10:00 12.6 2 17.9 6.5 12.2 2.1 16.8 5.3 0.4 0 0.4 0.4 121 13 121 305 90 0 90 0 1.8 0.2 2.2 1.5 04/27/2005 16:20:00 11.7 2 16.8 6.8 11.2 1.9 17.2 6.8 0.4 0 0.4 0.4 121 12 116 305 91 0 90 0 1.7 0.2 2.2 1.5 04/27/2005 16:30:00 11.7 2.1 16.8 6.5 11.6 2.1 17.2 6.5 0.4 0 0.4 0.4 121 16 125 305 91 0 91 0 1.7 0.2 2.2 1.5 04/27/2005 16:40:00 12.1 2.2 18.7 7.2 11.7 2.3 17.6 6.5 0.4 0 0.4 0.4 119 13 128 305 91 0 91 0 1.7 0.2 2.2 1.5 04/27/2005 16:50:00 13.1 2.2 19.5 7.2 12.4 2.2 19.5 6.8 0.4 0 0.4 0.4 120 14 116 305 91 0 91 0 1.7 0.2 2.2 1.5 04/27/2005 17:00:00 13.5 2.2 23.7 8 13.3 2.2 21.4 8 0.4 0 0.4 0.4 122 13 131 305 91 0 91 0 1.7 0.2 2.2 1.5 04/27/2005 17:10:00 14.8 2.3 22.6 8.4 14.7 2.4 21.4 8.4 0.4 0 0.4 0.4 129 11 121 305 93 3 92 0 1.7 0.2 2.2 1.5 04/27/2005 17:20:00 14.5 2.6 21.8 8.8 14.2 2.5 21.4 8 0.4 0 0.4 0.4 131 12 134 305 99 0 99 0 1.7 0.2 2.2 1.5 04/27/2005 17:30:00 14.7 2.6 20.6 7.6 14.3 2.5 19.5 7.6 0.4 0 0.4 0.4 131 11 140 305 100 1 100 0 1.7 0.1 2.2 1.5 04/27/2005 17:40:00 15.9 2 20.2 9.5 15.5 2.1 20.2 8.8 0.4 0 0.4 0.4 132 9 142 305 102 1 101 0 1.7 0.2 2.2 1.5 04/27/2005 17:50:00 15.6 1.7 19.5 11.1 15.1 1.7 19.9 9.1 0.4 0 0.4 0.4 132 9 128 305 104 0 103 0 1.6 0.1 2.2 1.5 04/27/2005 18:00:00 16.8 1.5 20.6 13 16.2 1.6 20.6 11.5 0.4 0 0.4 0.4 133 6 133 305 104 0 103 0 1.7 0.1 2.2 1.5 04/27/2005 18:10:00 16.5 1.5 19.9 11.8 15.9 1.4 19.9 11.5 0.4 0 0.4 0.4 133 6 130 305 104 1 103 0 1.7 0.2 2.2 1.5 04/27/2005 18:20:00 17.3 1.5 21.4 11.8 16.9 1.5 21 11.8 0.4 0 0.4 0.4 134 6 132 305 103 0 103 0 1.7 0.2 2.2 1.5 04/27/2005 18:30:00 16.7 1.6 20.2 12.2 16.3 1.6 19.9 11.5 0.4 0 0.4 0.4 134 6 119 305 101 1 101 0 1.7 0.1 2.2 1.5 04/27/2005 18:40:00 16.8 1.5 20.6 12.6 16.2 1.5 20.2 13 0.4 0 0.4 0.4 134 6 135 305 100 0 99 0 1.7 0.1 2.2 1.5 04/27/2005 18:50:00 16.6 1.5 19.9 11.5 16.1 1.5 19.9 11.5 0.4 0 0.4 0.4 133 6 130 305 99 0 99 0 1.6 0.1 2.2 1.5 04/27/2005 19:00:00 16.5 1.5 20.6 13 16 1.5 20.6 11.1 0.4 0 0.4 0.4 134 6 131 305 98 0 97 0 1.6 0.1 2.2 1.3 04/27/2005 19:10:00 17 1.5 20.6 11.8 16.5 1.4 20.2 11.8 0.4 0 0.4 0.4 135 6 131 305 97 0 97 0 1.6 0.1 2.2 1.5 04/27/2005 19:20:00 16.7 1.3 20.2 11.8 16.1 1.3 19.1 11.5 0.4 0 0.4 0.4 133 5 138 305 94 1 95 0 1.4 0.2 2 1.3 04/27/2005 19:30:00 16.4 1.7 21.4 10.3 15.9 1.7 21 11.1 0.4 0 0.4 0.4 131 6 131 305 92 0 92 0 1.4 0.2 2 1.3 04/27/2005 19:40:00 17.7 1.3 21.8 14.1 17.1 1.5 21 13.3 0.4 0 0.4 0.4 131 5 141 305 91 0 90 0 1.4 0.2 2 1.3 04/27/2005 19:50:00 15.3 2.2 21.4 10.3 15 2.2 22.1 9.9 0.4 0 0.4 0.4 125 12 118 305 90 0 90 0 1.4 0.2 2 1.3 04/27/2005 20:00:00 14.2 2 21 9.5 14 2 20.2 9.5 0.4 0 0.4 0.4 123 13 123 305 89 0 90 0 1.3 0.2 2 1.3 04/27/2005 20:10:00 14.6 2.1 18.7 8 14.1 2.3 19.1 6.8 0.4 0 0.4 0.4 122 12 106 305 89 0 89 0 1.3 0.2 1.7 1 04/27/2005 20:20:00 14.8 2.1 21 8.4 14.6 1.9 21.4 9.5 0.4 0 0.4 0.4 131 11 135 305 89 0 89 0 1.2 0.1 1.5 1 04/27/2005 20:30:00 13.4 2.2 20.2 6.8 13.3 2.2 18.7 7.6 0.4 0 0.4 0.4 126 12 120 305 88 0 88 0 1.1 0.1 1.5 1 04/27/2005 20:40:00 16 1.6 19.5 10.7 15.6 1.6 20.2 10.3 0.4 0 0.4 0.4 134 6 131 305 89 0 88 0 1 0 1.5 0.8 04/27/2005 20:50:00 17.1 1.5 20.6 13 16.7 1.5 20.2 12.2 0.4 0 0.4 0.4 135 5 134 305 93 3 91 0 0.9 0.1 1.5 0.8 04/27/2005 21:00:00 17.5 1.4 20.2 13 17.1 1.5 20.2 13 0.4 0 0.4 0.4 132 6 134 305 96 0 95 0 0.9 0.1 1.5 0.6 04/27/2005 21:10:00 17.5 1.4 20.2 13.3 17.2 1.5 20.2 12.6 0.4 0 0.4 0.4 135 5 140 305 98 1 98 0 0.7 0.2 1.3 0.6 04/27/2005 21:20:00 17.3 1.1 19.9 13.7 16.9 1.1 19.5 13.3 0.4 0 0.4 0.4 133 4 137 305 99 0 99 0 0.6 0.1 1 0.3 04/27/2005 21:30:00 16.7 1.2 19.5 12.2 16.3 1.3 19.5 12.6 0.4 0 0.4 0.4 135 5 138 305 100 1 101 0 0.5 0 1 0.3 04/27/2005 21:40:00 17.1 1.2 19.9 13 16.7 1.2 19.9 12.6 0.4 0 0.4 0.4 135 4 135 305 100 0 100 0 0.6 0 1 0.3 04/27/2005 21:50:00 15.6 1.3 18.3 11.1 15.1 1.3 17.9 11.5 0.4 0 0.4 0.4 134 5 131 305 100 0 100 0 0.6 0 1 0.6 04/27/2005 22:00:00 14.8 1.1 17.2 11.5 14.4 1.1 16.8 11.8 0.4 0 0.4 0.4 134 5 130 305 100 0 100 0 0.5 0 1 0.6 04/27/2005 22:10:00 13.9 1.3 17.2 9.9 13.4 1.2 16.4 9.5 0.4 0 0.4 0.4 133 5 131 305 100 0 100 0 0.5 0 1 0.3 04/27/2005 22:20:00 13 1.3 15.6 9.5 12.7 1.3 15.6 9.5 0.4 0 0.4 0.4 133 6 134 305 100 0 100 0 0.4 0 0.8 0.3 04/27/2005 22:30:00 11.8 1.9 16.1 6.5 11.8 1.7 15.3 6.8 0.4 0 0.4 0.4 139 9 134 305 100 0 100 0 0.3 0 0.6 0.3 04/27/2005 22:40:00 12 1.5 16.8 7.2 12 1.5 17.6 6.1 0.4 0 0.4 0.4 135 9 142 305 100 0 100 0 0.3 0 0.6 0.1 04/27/2005 22:50:00 10.4 1.7 14.5 6.1 10.5 1.7 15.6 6.5 0.4 0 0.4 0.4 141 11 136 305 100 0 100 0 0.3 0 0.6 0.1 04/27/2005 23:00:00 9.9 1.7 14.1 5.7 9.9 1.8 14.1 5.7 0.4 0 0.4 0.4 144 11 147 305 99 0 100 0 0.2 0.1 0.6 0.1 04/27/2005 23:10:00 9 1.5 12.6 4.6 9.1 1.5 13.3 5.3 0.4 0 0.4 0.4 144 12 142 305 102 2 100 0 0.2 0 0.6 0.1 04/27/2005 23:20:00 9.7 1.7 14.1 5.3 10 1.7 14.1 5.7 0.4 0 0.4 0.4 145 9 152 305 102 0 103 0 0.2 0.1 0.6 0.1 04/27/2005 23:30:00 8.8 1.5 12.2 5.3 9 1.5 13.3 5.7 0.4 0 0.4 0.4 144 12 147 305 102 0 102 0 0.1 0 0.6 0.1 04/27/2005 23:40:00 8.4 1.3 11.8 4.9 8.4 1.2 12.2 5.3 0.4 0 0.4 0.4 139 10 156 305 102 0 102 0 0 0 0.6 0.1 04/27/2005 23:50:00 10.2 1.3 13.3 6.1 10.3 1.4 13.3 6.5 0.4 0 0.4 0.4 133 7 145 305 101 0 101 0 0 0 0.3 0.1 04/28/2005 00:00:00 9.6 1.4 13.3 6.1 9.7 1.5 13.3 5.3 0.4 0 0.4 0.4 132 8 134 305 101 0 101 0 0 0.1 0.6 0.1 04/28/2005 00:10:00 9.5 1 12.6 6.1 9.7 1.1 12.6 6.1 0.4 0 0.4 0.4 133 7 145 305 101 0 101 0 0.2 0.1 0.6 0.1 04/28/2005 00:20:00 9.7 1.2 12.2 6.5 9.8 1.3 13.3 6.5 0.4 0 0.4 0.4 134 7 124 305 101 0 101 0 0.3 0 0.6 0.1 04/28/2005 00:30:00 10.1 1.1 12.6 6.8 10.3 1 13 7.2 0.4 0 0.4 0.4 134 7 124 305 102 0 101 0 0.4 0 0.8 0.3 04/28/2005 00:40:00 9.1 1.6 13 4.6 9.4 1.7 12.6 5.7 0.4 0 0.4 0.4 142 12 145 305 102 0 101 0 0.5 0 1 0.3 04/28/2005 00:50:00 10.2 1.2 13.7 7.2 10.3 1.3 13.3 6.8 0.4 0 0.4 0.4 136 8 147 305 102 0 103 0 0.5 0 1 0.3 04/28/2005 01:00:00 10.9 1.3 13.7 7.2 11.2 1.4 14.1 8 0.4 0 0.4 0.4 137 9 138 305 102 0 103 0 0.5 0 1 0.6 04/28/2005 01:10:00 12.4 1.1 15.3 9.1 12.5 1.1 15.3 9.1 0.4 0 0.4 0.4 134 5 132 305 102 0 102 0 0.5 0 1 0.6 04/28/2005 01:20:00 12.6 0.9 14.9 9.9 12.4 0.9 14.9 9.9 0.4 0 0.4 0.4 134 6 134 305 102 0 101 0 0.5 0 1 0.6 04/28/2005 01:30:00 12.7 1 15.3 9.9 12.4 1.1 14.9 9.9 0.4 0 0.4 0.4 130 6 136 305 101 0 101 0 0.5 0 1 0.6 04/28/2005 01:40:00 12.8 1.6 17.2 7.6 12.5 1.5 16.8 7.2 0.4 0 0.4 0.4 129 7 130 305 101 0 101 0 0.7 0 1 0.6 04/28/2005 01:50:00 12.3 1.4 16.4 9.1 12 1.4 16.4 8.8 0.4 0 0.4 0.4 132 8 129 305 100 1 100 0 0.8 0 1.3 0.6 04/28/2005 02:00:00 13.2 1.3 16.8 9.5 12.9 1.3 15.6 9.5 0.4 0 0.4 0.4 133 6 131 305 100 0 100 0 0.9 0 1.3 0.8 04/28/2005 02:10:00 13.1 1.4 16.8 9.9 12.8 1.3 16.8 9.5 0.4 0 0.4 0.4 132 6 135 305 100 0 100 0 1 0 1.5 1 04/28/2005 02:20:00 11.9 1.1 14.9 8.8 11.6 1 14.5 8.8 0.4 0 0.4 0.4 134 6 141 305 99 0 99 0 1 0 1.5 1 04/28/2005 02:30:00 12.4 1.1 15.3 8.8 12.1 1.1 15.3 8.8 0.4 0 0.4 0.4 134 6 137 305 100 0 100 0 1 0 1.5 1 04/28/2005 02:40:00 12.3 1.2 15.6 9.1 12.1 1.1 15.3 9.1 0.4 0 0.4 0.4 135 6 133 305 101 0 101 0 1 0 1.5 1 04/28/2005 02:50:00 12.3 1.2 16.1 9.1 12 1.2 16.1 9.1 0.4 0 0.4 0.4 136 6 133 305 101 0 101 0 1.1 0 1.5 1 04/28/2005 03:00:00 12.5 1.3 15.6 8.4 12.2 1.2 15.3 8.4 0.4 0 0.4 0.4 137 6 135 305 101 0 101 0 1.2 0.1 1.5 1 04/28/2005 03:10:00 11.7 1.2 14.9 8.8 11.5 1.2 15.6 8.4 0.4 0 0.4 0.4 139 9 131 305 101 0 102 0 1.2 0.1 1.5 1 04/28/2005 03:20:00 11.8 1.4 16.4 8.4 11.6 1.3 16.1 8 0.4 0 0.4 0.4 138 9 124 305 101 0 101 0 1.2 0.1 1.5 1 04/28/2005 03:30:00 11.9 1.4 15.6 8.4 11.6 1.4 15.6 8.4 0.4 0 0.4 0.4 138 9 139 305 100 0 100 0 1.2 0.1 1.5 1 04/28/2005 03:40:00 12.1 1.3 16.1 8 11.9 1.3 16.1 7.2 0.4 0 0.4 0.4 138 8 144 305 100 0 101 0 1.2 0.1 1.5 1 04/28/2005 03:50:00 11.6 1.5 15.6 7.2 11.2 1.3 15.6 7.6 0.4 0 0.4 0.4 147 9 141 305 97 2 99 0 1.2 0.1 1.5 1 04/28/2005 04:00:00 11.8 1.5 15.6 6.8 11.5 1.3 14.5 6.8 0.4 0 0.4 0.4 148 8 157 305 95 1 94 0 1.2 0.1 1.5 1 04/28/2005 04:10:00 13.2 1.4 16.4 8.8 12.7 1.2 15.6 9.1 0.4 0 0.4 0.4 148 6 150 305 92 0 92 0 1.2 0.1 1.7 1 04/28/2005 04:20:00 13.1 1.3 17.2 9.1 12.6 1.3 16.4 8.8 0.4 0 0.4 0.4 146 7 150 305 92 0 92 0 1.2 0 1.5 1 04/28/2005 04:30:00 12.8 1.6 16.8 9.9 12.5 1.5 17.6 9.5 0.4 0 0.4 0.4 146 8 154 305 91 0 91 0 1.2 0 1.5 1 04/28/2005 04:40:00 13.9 1.5 17.6 9.1 13.3 1.5 16.8 9.5 0.4 0 0.4 0.4 147 6 148 305 90 0 91 0 1.2 0 1.5 1 04/28/2005 04:50:00 13.2 1.5 17.2 9.5 12.8 1.4 17.2 9.1 0.4 0 0.4 0.4 145 8 148 305 89 0 89 0 1.2 0 1.5 1 04/28/2005 05:00:00 14 1.6 17.9 9.9 13.7 1.5 18.3 9.5 0.4 0 0.4 0.4 146 7 150 305 88 0 88 0 1.2 0 1.5 1 04/28/2005 05:10:00 14.1 1.6 18.3 9.5 13.8 1.5 18.3 9.9 0.4 0 0.4 0.4 146 8 152 305 85 1 85 0 1.3 0 1.7 1 04/28/2005 05:20:00 14.2 1.6 18.7 9.5 13.7 1.5 17.6 10.3 0.4 0 0.4 0.4 145 7 143 305 83 0 84 0 1.2 0 1.7 1 04/28/2005 05:30:00 13.8 1.5 18.7 9.5 13.4 1.4 17.6 9.5 0.4 0 0.4 0.4 145 8 124 305 81 0 82 0 1.2 0 1.5 1 04/28/2005 05:40:00 14.5 1.5 18.3 9.9 14 1.4 17.6 9.9 0.4 0 0.4 0.4 146 7 139 305 79 0 79 0 1.2 0 1.5 1 04/28/2005 05:50:00 14.4 1.6 18.3 10.3 14 1.5 17.6 10.3 0.4 0 0.4 0.4 146 7 136 305 75 3 79 0 1.1 0.1 1.5 1 04/28/2005 06:00:00 13.9 1.7 17.9 9.9 13.5 1.5 18.3 9.9 0.4 0 0.4 0.4 146 8 155 305 69 1 68 0 1.2 0.1 1.5 1 04/28/2005 06:10:00 13.8 1.7 17.9 9.9 13.3 1.5 17.2 9.1 0.4 0 0.4 0.4 147 8 158 305 71 0 71 0 1.2 0.1 1.5 1 04/28/2005 06:20:00 14.3 1.6 17.9 8.8 13.8 1.4 17.6 10.3 0.4 0 0.4 0.4 147 7 144 305 72 0 72 0 1.2 0.1 1.7 1 04/28/2005 06:30:00 14.3 1.5 17.9 9.9 13.7 1.5 16.8 10.3 0.4 0 0.4 0.4 146 8 145 305 72 0 72 0 1.3 0.1 1.5 1 04/28/2005 06:40:00 13.9 1.7 17.6 8 13.5 1.5 16.8 9.9 0.4 0 0.4 0.4 147 7 141 305 74 1 72 0 1.2 0.1 1.5 1 04/28/2005 06:50:00 13.4 1.8 17.9 8 12.9 1.5 16.8 9.5 0.4 0 0.4 0.4 148 7 154 305 75 0 75 0 1.2 0.1 1.5 1 04/28/2005 07:00:00 12.8 1.7 17.2 8 12.6 1.5 16.4 9.1 0.4 0 0.4 0.4 149 8 149 305 75 0 75 0 1.2 0.1 1.5 1 04/28/2005 07:10:00 12.4 1.8 16.1 6.5 12.2 1.5 16.8 8.4 0.4 0 0.4 0.4 149 8 160 305 75 0 76 0 1 0 1.5 1 04/28/2005 07:20:00 12.9 1.6 16.1 8.4 12.5 1.5 16.1 8.8 0.4 0 0.4 0.4 148 7 150 305 76 0 76 0 1 0 1.5 1 04/28/2005 07:30:00 13.4 1.3 16.4 9.5 12.8 1.2 16.1 9.5 0.4 0 0.4 0.4 147 6 147 305 77 0 76 0 1 0 1.5 1 04/28/2005 07:40:00 12.8 1.5 16.1 7.6 12.3 1.3 15.6 9.1 0.4 0 0.4 0.4 147 8 144 305 77 0 77 0 1.1 0 1.5 1 04/28/2005 07:50:00 11.9 1.5 15.3 5.3 11.4 1.2 14.5 7.6 0.4 0 0.4 0.4 149 7 151 305 77 0 77 0 1.1 0 1.5 1 04/28/2005 08:00:00 11.8 1.5 15.3 7.6 11.5 1.2 14.5 8.4 0.4 0 0.4 0.4 149 7 150 305 77 0 78 0 1.1 0 1.5 1 04/28/2005 08:10:00 12 1.3 15.3 7.6 11.6 1.2 14.9 8.4 0.4 0 0.4 0.4 148 8 153 305 77 0 77 0 1.1 0 1.5 1 04/28/2005 08:20:00 11.6 1.3 14.5 8 11.1 1.2 13.7 8 0.4 0 0.4 0.4 149 7 150 305 77 0 77 0 1.1 0 1.5 1 04/28/2005 08:30:00 12.1 1.2 15.6 8.8 11.6 1.2 15.6 8.4 0.4 0 0.4 0.4 148 7 150 305 77 0 77 0 1.1 0 1.5 1 04/28/2005 08:40:00 12.1 1.3 15.6 8.4 11.7 1.2 15.6 8 0.4 0 0.4 0.4 149 7 149 305 77 0 78 0 1.1 0 1.5 1 04/28/2005 08:50:00 12.1 1.3 15.6 8.8 11.7 1.2 15.3 8.4 0.4 0 0.4 0.4 149 6 151 305 78 0 78 0 1.1 0 1.3 1 04/28/2005 09:00:00 11.4 1.3 14.5 6.5 11.1 1.2 13.7 8 0.4 0 0.4 0.4 149 7 145 305 78 0 78 0 1 0 1.3 1 04/28/2005 09:10:00 11.9 1.3 15.3 8.4 11.6 1.1 14.5 8.8 0.4 0 0.4 0.4 150 6 147 305 78 0 78 0 1 0 1.3 1 04/28/2005 09:20:00 12.6 1.3 15.6 8.8 11.9 1.2 14.9 8.4 0.4 0 0.4 0.4 150 5 149 305 78 0 78 0 1 0 1.3 1 04/28/2005 09:30:00 12.8 1.3 15.6 8.8 12.3 1.1 14.9 9.1 0.4 0 0.4 0.4 150 5 148 305 78 0 78 0 1 0 1.3 1 04/28/2005 09:40:00 12.7 1.4 15.6 7.6 12.4 1.1 14.9 8.8 0.4 0 0.4 0.4 150 6 157 305 78 0 78 0 1 0 1.3 1 04/28/2005 09:50:00 13.1 1.3 16.4 8.8 12.7 1.1 15.3 10.3 0.4 0 0.4 0.4 151 6 151 305 78 0 78 0 1.1 0 1.3 1 04/28/2005 10:00:00 12.7 1.3 15.6 8.8 12.4 1.1 14.9 9.1 0.4 0 0.4 0.4 152 6 149 305 78 0 78 0 1.2 0 1.5 1 04/28/2005 10:10:00 12.3 1.5 15.3 8 12.1 1.3 14.9 8.8 0.4 0 0.4 0.4 152 7 154 305 78 0 77 0 1.2 0 1.3 1 04/28/2005 10:20:00 13.1 1.5 16.1 8 12.9 1.1 16.1 9.5 0.4 0 0.4 0.4 152 6 157 305 77 0 78 0 1.1 0 1.3 1 04/28/2005 10:30:00 12.4 1.5 15.6 7.6 12.3 1.2 15.6 9.5 0.4 0 0.4 0.4 152 6 144 305 77 0 78 0 1.1 0 1.5 1 04/28/2005 10:40:00 12.6 1.5 15.6 8 12.4 1.2 16.1 9.1 0.4 0 0.4 0.4 151 6 154 305 77 0 77 0 1.2 0 1.3 1 04/28/2005 10:50:00 11.4 1.6 14.5 7.2 11.5 1.1 14.1 8.4 0.4 0 0.4 0.4 154 7 150 305 77 0 77 0 1.2 0 1.7 1 04/28/2005 11:00:00 11.4 1.7 14.9 7.2 11.2 1.3 13.7 7.6 0.4 0 0.4 0.4 153 6 151 305 77 0 77 0 1.3 0 2 1.3 04/28/2005 11:10:00 10.3 1.3 13.7 6.8 10.3 1.2 13 7.2 0.4 0 0.4 0.4 153 7 157 305 75 1 76 0 1.3 0.1 1.7 1.3 04/28/2005 11:20:00 9.4 1.5 14.1 5.7 9.7 1.2 12.6 6.8 0.4 0 0.4 0.4 154 7 156 305 73 0 73 0 1.4 0 2 1.3 04/28/2005 11:30:00 9.2 1.3 13 4.6 9.5 1.1 12.2 7.2 0.4 0 0.4 0.4 154 8 156 305 72 1 72 0 1.5 0 2 1.3 04/28/2005 11:40:00 9.2 1.3 12.2 4.2 9.2 1.1 13 6.1 0.4 0 0.4 0.4 153 8 154 305 70 0 71 0 1.5 0 2 1.3 04/28/2005 11:50:00 10.3 1.3 13 6.5 9.9 1 12.2 6.8 0.4 0 0.4 0.4 150 6 148 305 70 0 70 0 1.4 0 2 1.3 04/28/2005 12:00:00 10 1.1 12.6 5.7 9.6 0.8 11.8 6.8 0.4 0 0.4 0.4 149 6 144 305 70 0 70 0 1.5 0 2 1.3 04/28/2005 12:10:00 9.4 1.2 11.8 5.7 9.2 1 11.5 6.8 0.4 0 0.4 0.4 150 5 154 305 70 0 71 0 1.6 0 2 1.5 04/28/2005 12:20:00 10.5 1 13.3 8 10 0.8 11.8 7.6 0.4 0 0.4 0.4 150 5 152 305 70 0 70 0 1.6 0 2 1.5 04/28/2005 12:30:00 10.3 1 13 7.6 9.9 0.9 11.8 7.2 0.4 0 0.4 0.4 149 6 156 305 70 0 71 0 1.6 0 2 1.5 04/28/2005 12:40:00 9.7 1 11.8 6.8 9.3 0.8 11.5 6.8 0.4 0 0.4 0.4 148 6 156 305 70 0 71 0 1.6 0 2.2 1.5 04/28/2005 12:50:00 11.5 1 13.7 8 10.9 0.8 13.7 8.8 0.4 0 0.4 0.4 150 5 146 305 70 1 73 0 1.6 0 2.2 1.5 04/28/2005 13:00:00 12 1 14.5 8.4 11.4 0.8 13.7 9.1 0.4 0 0.4 0.4 152 4 152 305 73 0 73 0 1.4 0 2 1.3 04/28/2005 13:10:00 10.3 1.5 13 6.1 11 0.8 12.6 8.8 0.4 0 0.4 0.4 158 5 158 305 74 0 74 0 1.5 0 2 1.3 04/28/2005 13:20:00 11.6 1.4 14.5 7.2 11.7 0.8 13.3 9.9 0.4 0 0.4 0.4 156 4 152 305 73 0 74 0 1.4 0 2 1.3 04/28/2005 13:30:00 11.2 1.7 14.9 6.8 12 0.9 14.5 9.5 0.4 0 0.4 0.4 158 5 156 305 73 0 73 0 1.5 0 2 1.3 04/28/2005 13:40:00 13.2 1.4 15.3 8.4 13 0.7 14.9 10.7 0.4 0 0.4 0.4 155 4 152 305 76 1 76 0 1.6 0.2 2.2 1.3 04/28/2005 13:50:00 9.8 1.7 14.1 6.1 12 0.8 14.1 9.1 0.4 0 0.4 0.4 162 5 155 305 76 0 75 0 1.7 0.2 2.5 1.5 04/28/2005 14:00:00 12.7 0.9 14.9 9.9 12.2 0.8 14.1 9.5 0.4 0 0.4 0.4 151 4 153 305 75 1 75 0 1.9 0.2 2.5 1.5 04/28/2005 14:10:00 11.4 1.2 13.7 8 10.9 1.1 13.3 7.2 0.4 0 0.4 0.4 151 4 146 305 77 0 77 0 2.2 0.2 2.9 1.7 04/28/2005 14:20:00 8.4 1.9 11.8 3.8 8 1.7 11.5 3.8 0.4 0 0.4 0.4 145 9 151 305 76 0 76 0 2.9 0.2 3.7 2.5 04/28/2005 14:30:00 7.1 1.2 11.1 3.8 6.9 1 10.7 3.8 0.4 0 0.4 0.4 128 11 147 305 76 0 76 0 3.6 0.2 4.2 3.2 04/28/2005 14:40:00 6.9 0.8 8.8 4.2 6.9 0.8 9.1 4.6 0.4 0 0.4 0.4 137 10 144 305 75 0 76 0 3.1 0.4 3.9 2.5 04/28/2005 14:50:00 6.1 1.2 9.1 2.6 6.3 0.8 9.1 3.8 0.4 0 0.4 0.4 146 13 131 305 76 0 77 0 2.3 0.1 2.9 2.2 04/28/2005 15:00:00 7.4 0.8 10.7 5.7 7.3 0.8 10.3 5.3 0.4 0 0.4 0.4 136 7 145 305 78 1 79 0 2.3 0.1 2.7 2.2 04/28/2005 15:10:00 9.3 0.7 11.1 6.8 9.2 0.6 11.1 6.8 0.4 0 0.4 0.4 132 5 133 305 80 0 80 0 2.2 0.2 2.7 2 04/28/2005 15:20:00 9.2 0.7 10.7 6.8 9 0.6 10.7 6.8 0.4 0 0.4 0.4 139 4 133 305 81 0 81 0 1.8 0.1 2.2 1.5 04/28/2005 15:30:00 9.8 0.7 11.5 7.6 9.6 0.7 11.5 7.6 0.4 0 0.4 0.4 140 5 136 305 83 0 83 0 1.7 0.1 2.2 1.5 04/28/2005 15:40:00 10.4 0.7 12.2 8.4 10.1 0.7 11.8 8.4 0.4 0 0.4 0.4 140 4 149 305 84 0 84 0 1.6 0 2 1.5 04/28/2005 15:50:00 9.5 1 11.8 6.5 9.4 0.9 11.8 7.2 0.4 0 0.4 0.4 142 7 142 305 85 0 85 0 1.5 0 2 1.3 04/28/2005 16:00:00 8.7 1 11.1 5.7 8.6 1 11.5 5.7 0.4 0 0.4 0.4 146 8 135 305 85 0 85 0 1.6 0 2 1.5 04/28/2005 16:10:00 7.5 0.8 9.1 4.6 7.4 0.7 9.5 5.3 0.4 0 0.4 0.4 149 7 151 305 85 0 85 0 1.4 0 2 1.3 04/28/2005 16:20:00 7.3 1.1 10.3 4.9 7.2 1 9.5 4.9 0.4 0 0.4 0.4 147 7 154 305 86 0 86 0 1.4 0 2 1.3 04/28/2005 16:30:00 8.8 0.7 11.1 6.5 8.6 0.6 10.3 7.2 0.4 0 0.4 0.4 149 5 154 305 86 0 86 0 1.3 0.1 1.7 1 04/28/2005 16:40:00 9.9 0.9 11.8 7.6 9.4 0.7 11.1 6.5 0.4 0 0.4 0.4 155 3 155 305 87 0 87 0 1.2 0.1 1.7 1 04/28/2005 16:50:00 7.6 1.7 11.1 4.6 10.3 0.7 11.8 8 0.4 0 0.4 0.4 165 6 156 305 88 0 88 0 1.5 0.1 2.2 1.3 04/28/2005 17:00:00 7.2 1.7 13 4.9 10.7 0.6 12.6 9.1 0.4 0 0.4 0.4 167 5 156 305 88 0 87 0 2 0 2.5 1.7 04/28/2005 17:10:00 7.4 2.2 13 3.8 8.7 1.5 12.2 5.3 0.4 0 0.4 0.4 162 6 156 305 87 0 87 0 1.9 0 2.5 1.7 04/28/2005 17:20:00 5.7 1 8 3 6.4 0.7 8.8 4.6 0.4 0 0.4 0.4 160 7 155 305 86 0 86 0 1.7 0.1 2.2 1.5 04/28/2005 17:30:00 7.9 0.8 9.9 5.3 7.6 0.7 9.1 5.3 0.4 0 0.4 0.4 152 5 158 305 86 0 86 0 1.4 0 2 1.3 04/28/2005 17:40:00 7.5 1.1 9.1 4.2 8 0.5 9.9 6.5 0.4 0 0.4 0.4 158 4 164 305 87 0 87 0 1.3 0 1.7 1.3 04/28/2005 17:50:00 6.1 1 8.8 3.8 9.1 1.1 11.8 6.8 0.4 0 0.4 0.4 167 5 165 305 88 0 88 0 1.4 0.1 2.2 1.3 04/28/2005 18:00:00 7.2 1.1 10.3 4.6 10 0.7 11.8 7.6 0.4 0 0.4 0.4 176 5 189 305 88 0 88 0 1.9 0.1 2.5 1.5 04/28/2005 18:10:00 6.7 1.2 9.9 4.2 9.3 1 11.8 6.8 0.4 0 0.4 0.4 174 6 174 305 89 0 88 0 2.1 0.2 2.7 2 04/28/2005 18:20:00 5.8 1 9.1 3 8.1 0.9 10.7 5.3 0.4 0 0.4 0.4 170 7 186 305 88 0 88 0 2.3 0.1 2.7 2.2 04/28/2005 18:30:00 5.4 1.1 9.1 2.6 7.3 1.1 10.3 4.6 0.4 0 0.4 0.4 174 6 183 305 87 0 87 0 2.3 0.1 2.7 2 04/28/2005 18:40:00 5.3 1.1 8.4 2.6 7.2 1.2 10.3 4.2 0.4 0 0.4 0.4 174 7 187 305 86 0 86 0 2.1 0.2 2.7 2 04/28/2005 18:50:00 5.5 1.1 8.8 3 7.1 1 9.1 4.9 0.4 0 0.4 0.4 173 8 181 305 85 0 86 0 2.3 0.1 2.9 2.2 04/28/2005 19:00:00 5.1 1.2 8.8 2.3 6.1 1 8.8 3.8 0.4 0 0.4 0.4 170 10 160 305 84 0 84 0 2.3 0.1 2.7 2 04/28/2005 19:10:00 4.9 1 7.2 2.3 5.1 0.9 7.2 3.4 0.4 0 0.4 0.4 155 11 160 305 83 0 83 0 1.6 0.2 2.5 1.3 04/28/2005 19:20:00 6.3 0.6 7.6 4.9 6.2 0.6 7.2 4.6 0.4 0 0.4 0.4 144 5 143 305 83 0 82 0 1 0 1.5 0.8 04/28/2005 19:30:00 5.9 0.8 8 3.8 5.9 0.6 7.2 4.2 0.4 0 0.4 0.4 148 7 155 305 84 0 84 0 0.9 0.1 1.3 0.8 04/28/2005 19:40:00 6.7 0.8 8.4 4.2 6.5 0.7 8 4.6 0.4 0 0.4 0.4 153 4 150 305 85 0 86 0 0.8 0.2 1.3 0.6 04/28/2005 19:50:00 6.6 0.9 8.4 3.4 6.7 0.5 8 4.9 0.4 0 0.4 0.4 157 4 152 305 87 0 87 0 0.6 0.2 1 0.6 04/28/2005 20:00:00 7.1 0.8 8.4 4.9 7.1 0.5 8 5.7 0.4 0 0.4 0.4 157 4 154 305 89 0 88 0 0.6 0.2 1.3 0.6 04/28/2005 20:10:00 6.8 0.8 8.8 4.2 6.7 0.6 8.4 4.9 0.4 0 0.4 0.4 156 4 156 305 90 1 91 0 0.6 0.1 1.3 0.6 04/28/2005 20:20:00 6.9 0.9 9.1 4.6 7 0.5 8.4 5.7 0.4 0 0.4 0.4 157 5 158 305 92 0 93 0 0.7 0.1 1.3 0.6 04/28/2005 20:30:00 5.5 1.1 8.4 3.4 7.3 0.6 8.4 5.3 0.4 0 0.4 0.4 166 5 161 305 94 0 93 0 0.8 0 1.3 0.6 04/28/2005 20:40:00 4.9 1 8 3 6.7 0.6 8.4 4.9 0.4 0 0.4 0.4 173 7 190 305 94 0 94 0 1.2 0.2 2 0.8 04/28/2005 20:50:00 6.2 1 8 3.4 7.1 0.7 8.8 4.9 0.4 0 0.4 0.4 181 5 183 305 95 0 95 0 1.6 0.1 2.2 1.5 04/28/2005 21:00:00 7.9 0.6 8.8 5.7 8.3 0.5 9.1 6.8 0.4 0 0.4 0.4 186 3 183 305 94 0 94 0 1.6 0 2.2 1.3 04/28/2005 21:10:00 7.5 0.4 8.4 6.1 7.8 0.5 8.8 6.5 0.4 0 0.4 0.4 186 3 188 305 93 0 93 0 1.5 0 2.2 1.3 04/28/2005 21:20:00 7.7 0.5 9.1 4.6 8 0.5 9.1 6.5 0.4 0 0.4 0.4 187 3 188 305 92 0 92 0 1.6 0 2.2 1.5 04/28/2005 21:30:00 7.9 0.4 8.8 6.5 8.2 0.4 9.5 7.2 0.4 0 0.4 0.4 187 3 187 305 91 0 91 0 1.6 0.1 2.2 1.5 04/28/2005 21:40:00 7.6 0.7 8.8 4.9 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 186 3 188 305 90 0 90 0 1.6 0 2.2 1.5 04/28/2005 21:50:00 6.7 0.8 8.8 4.2 7.4 0.6 9.1 5.3 0.4 0 0.4 0.4 182 3 187 305 89 0 90 0 1.7 0.1 2.2 1.5 04/28/2005 22:00:00 5.7 1.2 7.6 3 6.9 0.8 8.4 5.3 0.4 0 0.4 0.4 180 5 187 305 88 0 88 0 1.8 0.1 2.2 1.5 04/28/2005 22:10:00 6.2 0.8 8 3.4 6.7 0.6 8 4.9 0.4 0 0.4 0.4 184 5 191 305 88 0 88 0 1.5 0.1 2.2 1.3 04/28/2005 22:20:00 5.3 0.8 6.8 3 6 0.6 7.2 4.6 0.4 0 0.4 0.4 182 4 186 305 88 0 88 0 1.3 0.1 2 1.3 04/28/2005 22:30:00 4.1 1 6.1 1.5 5.3 0.7 6.8 3.8 0.4 0 0.4 0.4 176 7 179 305 88 0 88 0 1.3 0.1 2 1.3 04/28/2005 22:40:00 3.9 0.6 6.1 2.3 5.8 0.6 7.2 4.2 0.4 0 0.4 0.4 171 6 177 305 89 0 89 0 1.4 0.2 2 1.3 04/28/2005 22:50:00 4.9 1.2 8 2.6 6 0.9 7.6 3.8 0.4 0 0.4 0.4 177 8 187 305 90 0 91 0 1.5 0 2 1.3 04/28/2005 23:00:00 6.4 0.9 8.4 3.8 6.9 0.5 8 5.3 0.4 0 0.4 0.4 183 5 187 305 91 0 91 0 1.6 0.2 2.2 1.5 04/28/2005 23:10:00 4.5 1 6.8 1.9 5.6 0.7 7.2 3.8 0.4 0 0.4 0.4 179 5 184 305 91 0 91 0 1.7 0.2 2.2 1.5 04/28/2005 23:20:00 3.5 0.9 5.7 1.5 4.4 0.6 6.1 3 0.4 0 0.4 0.4 177 6 183 305 90 0 89 0 1.7 0.2 2.2 1.5 04/28/2005 23:30:00 5.3 0.5 6.5 3.4 5.6 0.4 6.8 4.6 0.4 0 0.4 0.4 187 5 184 305 89 0 88 0 1.7 0.2 2.2 1.5 04/28/2005 23:40:00 5.1 0.6 6.1 2.6 5.5 0.4 6.5 4.2 0.4 0 0.4 0.4 183 4 183 305 88 0 88 0 1.6 0.1 2.2 1.3 04/28/2005 23:50:00 5.3 0.9 6.8 3 5.9 0.6 7.2 4.6 0.4 0 0.4 0.4 183 5 188 305 87 0 87 0 1.6 0 2 1.3 04/29/2005 00:00:00 5.9 0.4 7.2 4.9 6 0.4 6.8 5.3 0.4 0 0.4 0.4 190 5 186 305 87 0 87 0 1.6 0.1 2.2 1.3 04/29/2005 00:10:00 5.3 0.9 7.2 2.6 5.7 0.6 7.2 4.2 0.4 0 0.4 0.4 187 6 186 305 86 0 86 0 1.5 0.1 2 1.3 04/29/2005 00:20:00 5.7 0.8 8 3.4 5.9 0.7 7.6 3.8 0.4 0 0.4 0.4 188 4 188 305 86 0 86 0 1.5 0.1 2.2 1.3 04/29/2005 00:30:00 5.9 0.6 7.2 4.2 6.2 0.5 7.2 4.9 0.4 0 0.4 0.4 187 5 189 305 85 0 86 0 1.5 0 2.2 1.3 04/29/2005 00:40:00 6.3 0.7 8.8 4.2 6.4 0.6 8 4.9 0.4 0 0.4 0.4 188 5 191 305 85 0 85 0 1.4 0 2 1.3 04/29/2005 00:50:00 6.6 0.6 8 4.2 6.5 0.5 8 5.3 0.4 0 0.4 0.4 192 5 188 305 85 0 85 0 1.6 0 2.2 1.3 04/29/2005 01:00:00 6 0.8 8.4 3.8 6 0.8 8.8 3.8 0.4 0 0.4 0.4 192 7 193 305 85 0 85 0 1.6 0 2.2 1.3 04/29/2005 01:10:00 6.1 0.6 8 4.2 5.9 0.6 7.6 4.2 0.4 0 0.4 0.4 196 6 191 305 84 0 85 0 1.4 0 2 1.3 04/29/2005 01:20:00 5.9 0.5 6.8 4.9 5.7 0.5 6.8 4.2 0.4 0 0.4 0.4 199 4 197 305 84 0 84 0 1.1 0 2 1 04/29/2005 01:30:00 6.8 0.4 8 5.7 6.6 0.4 8 5.3 0.4 0 0.4 0.4 198 3 199 305 84 0 84 0 0.9 0 1.3 0.8 04/29/2005 01:40:00 6.6 0.4 7.2 5.3 6.3 0.4 7.2 5.3 0.4 0 0.4 0.4 199 3 195 305 84 0 84 0 0.7 0.1 1.3 0.6 04/29/2005 01:50:00 6.7 0.3 7.6 6.1 6.4 0.4 7.2 5.3 0.4 0 0.4 0.4 199 2 198 305 84 0 85 0 0.6 0 1 0.6 04/29/2005 02:00:00 6.9 0.4 8 6.1 6.6 0.5 7.6 5.3 0.4 0 0.4 0.4 198 2 203 305 85 0 85 0 0.5 0 1 0.3 04/29/2005 02:10:00 7.4 0.3 8.4 6.5 7.2 0.4 8.4 5.7 0.4 0 0.4 0.4 200 2 200 305 86 0 86 0 0.4 0 1 0.3 04/29/2005 02:20:00 7 0.3 7.6 5.7 6.7 0.4 7.6 5.3 0.4 0 0.4 0.4 198 2 200 305 86 0 86 0 0.3 0 0.6 0.3 04/29/2005 02:30:00 6.5 0.4 7.2 4.9 6.1 0.5 7.6 4.6 0.4 0 0.4 0.4 197 3 198 305 87 0 87 0 0.2 0 0.6 0.1 04/29/2005 02:40:00 5.9 0.4 6.8 4.9 5.6 0.4 6.5 4.6 0.4 0 0.4 0.4 196 3 197 305 88 0 87 0 0.2 0.1 0.6 0.1 04/29/2005 02:50:00 6.1 0.3 6.8 4.9 5.8 0.4 6.8 4.6 0.4 0 0.4 0.4 198 3 200 305 88 0 88 0 0.1 0.1 0.6 0.1 04/29/2005 03:00:00 6.4 0.7 8.4 4.6 6.1 0.8 8 4.2 0.4 0 0.4 0.4 202 6 204 305 89 0 89 0 -0.1 0.1 0.6 -0.4 04/29/2005 03:10:00 6.5 0.6 7.6 4.2 6.2 0.7 7.6 4.2 0.4 0 0.4 0.4 209 5 199 305 89 0 90 0 -0.6 0 0.1 -0.8 04/29/2005 03:20:00 5.8 0.5 6.8 3.8 5.8 0.5 6.8 4.2 0.4 0 0.4 0.4 205 4 203 305 90 0 90 0 -0.8 0 -0.4 -0.8 04/29/2005 03:30:00 5.4 0.6 6.8 3.8 5.3 0.6 7.2 3.8 0.4 0 0.4 0.4 204 5 202 305 90 0 91 0 -0.8 0 -0.6 -1.1 04/29/2005 03:40:00 5.5 0.5 6.5 3.8 5.4 0.5 6.5 4.2 0.4 0 0.4 0.4 207 4 205 305 91 0 91 0 -1.1 0 -0.8 -1.3 04/29/2005 03:50:00 4.6 0.6 6.1 2.6 4.5 0.6 5.7 2.6 0.4 0 0.4 0.4 204 5 198 305 91 0 91 0 -1.3 0 -1.1 -1.3 04/29/2005 04:00:00 4.9 0.3 5.7 4.2 4.9 0.4 5.7 3.4 0.4 0 0.4 0.4 206 6 213 305 92 0 92 0 -1.3 0 -0.6 -1.5 04/29/2005 04:10:00 4.2 0.5 5.7 3 4.3 0.5 5.7 3 0.4 0 0.4 0.4 202 4 203 305 93 0 92 0 -1.5 0.1 -0.6 -1.8 04/29/2005 04:20:00 4 0.3 4.6 3.4 4.2 0.3 4.9 3 0.4 0 0.4 0.4 199 5 205 305 93 0 93 0 -1.6 0.1 -1.1 -1.8 04/29/2005 04:30:00 3.4 0.4 4.6 2.6 3.6 0.4 4.6 2.6 0.4 0 0.4 0.4 194 5 191 305 94 0 93 0 -1.4 0.1 -0.6 -1.8 04/29/2005 04:40:00 3.3 0.4 4.2 1.9 3.6 0.4 4.6 2.3 0.4 0 0.4 0.4 190 6 194 305 94 0 94 0 -1 0.2 -0.1 -1.1 04/29/2005 04:50:00 3.5 0.5 5.3 2.3 3.7 0.5 5.3 2.6 0.4 0 0.4 0.4 198 8 198 305 95 0 95 0 -0.3 0.1 0.3 -0.6 04/29/2005 05:00:00 4.2 0.4 5.7 3 4.3 0.5 5.3 2.6 0.4 0 0.4 0.4 202 6 198 305 96 0 95 0 -0.3 0 0.1 -0.4 04/29/2005 05:10:00 3.7 0.6 4.9 1.9 3.9 0.6 5.3 2.3 0.4 0 0.4 0.4 197 7 196 305 97 0 96 0 -0.4 0 0.1 -0.4 04/29/2005 05:20:00 3.9 0.4 4.9 2.3 4 0.5 4.9 2.6 0.4 0 0.4 0.4 200 7 203 305 97 0 97 0 -0.5 0 0.1 -0.6 04/29/2005 05:30:00 4.5 0.4 6.1 3.8 4.6 0.4 5.7 3.4 0.4 0 0.4 0.4 199 4 196 305 98 0 98 0 -0.6 0 -0.1 -0.6 04/29/2005 05:40:00 4.6 0.3 5.7 3.8 4.6 0.4 5.7 3.4 0.4 0 0.4 0.4 197 5 181 305 99 0 99 0 -0.8 0 -0.4 -1.1 04/29/2005 05:50:00 4.6 0.3 5.3 3.8 4.7 0.4 5.7 3.8 0.4 0 0.4 0.4 197 4 193 305 99 0 99 0 -0.8 0 -0.4 -1.1 04/29/2005 06:00:00 4.5 0.3 5.3 3.4 4.5 0.4 5.3 3.4 0.4 0 0.4 0.4 198 4 198 305 99 0 99 0 -0.8 0 -0.4 -1.1 04/29/2005 06:10:00 4.3 0.3 4.9 3.4 4.3 0.3 4.9 3 0.4 0 0.4 0.4 196 5 201 305 99 0 99 0 -0.9 0 -0.4 -1.1 04/29/2005 06:20:00 3.8 0.3 4.6 3 3.9 0.4 4.9 2.6 0.4 0 0.4 0.4 194 4 192 305 100 0 100 0 -0.8 0 -0.4 -0.8 04/29/2005 06:30:00 3.3 0.6 4.6 1.9 3.5 0.6 4.6 1.5 0.4 0 0.4 0.4 201 3 192 305 100 0 100 0 -0.7 0 -0.1 -0.8 04/29/2005 06:40:00 3.6 0.5 4.6 2.3 3.7 0.5 4.9 1.9 0.4 0 0.4 0.4 202 0 202 305 100 0 100 0 -0.6 0 0.1 -0.6 04/29/2005 06:50:00 3.4 0.4 4.6 2.3 3.5 0.5 4.6 2.3 0.4 0 0.4 0.4 202 0 202 305 101 0 101 0 -0.6 0 -0.1 -0.6 04/29/2005 07:00:00 4 0.3 4.9 3.4 4.1 0.3 4.9 3 0.4 0 0.4 0.4 202 0 202 305 101 0 101 0 -0.6 0 -0.1 -0.6 04/29/2005 07:10:00 3.9 0.5 4.9 2.6 3.8 0.5 4.9 2.3 0.4 0 0.4 0.4 202 0 202 305 102 0 101 0 -0.6 0 -0.1 -0.6 04/29/2005 07:20:00 3.5 0.5 4.6 2.3 3.5 0.4 4.6 2.6 0.4 0 0.4 0.4 202 0 202 305 102 0 102 0 -0.6 0 -0.1 -0.6 04/29/2005 07:30:00 3.1 0.4 4.2 1.9 3 0.5 4.2 1.9 0.4 0 0.4 0.4 202 0 202 305 102 0 102 0 -0.6 0 -0.1 -0.6 04/29/2005 07:40:00 2.5 0.4 3 1.5 2.5 0.4 3.4 1.5 0.4 0 0.4 0.4 202 0 202 305 102 0 102 0 -0.6 0 -0.1 -0.6 04/29/2005 07:50:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.5 0.4 0 0.4 0.4 202 0 202 305 102 0 103 0 -0.6 0 -0.1 -0.6 04/29/2005 08:00:00 2.2 0.4 3 1.1 2.1 0.4 3 1.1 0.4 0 0.4 0.4 202 0 202 305 102 0 103 0 -0.7 0 -0.1 -0.8 04/29/2005 08:10:00 2.5 0.5 3.4 1.1 2.4 0.5 3.4 1.1 0.4 0 0.4 0.4 202 0 202 305 103 0 103 0 -0.7 0 -0.4 -0.8 04/29/2005 08:20:00 2.5 0.4 3.4 1.5 2.3 0.4 3 1.1 0.4 0 0.4 0.4 202 0 202 305 102 0 103 0 -0.7 0 -0.4 -0.8 04/29/2005 08:30:00 1.8 0.3 2.6 0.7 1.8 0.3 2.6 1.1 0.4 0 0.4 0.4 202 0 202 305 102 0 103 0 -0.7 0 -0.4 -0.8 04/29/2005 08:40:00 0.5 0.3 1.9 0.4 1.4 0.3 2.3 0.7 0.4 0 0.4 0.4 202 0 202 305 102 0 102 0 -0.7 0 -0.1 -0.8 04/29/2005 08:50:00 0.4 0 0.4 0.4 1.9 0.4 3 0.7 0.4 0 0.4 0.4 202 0 305 305 102 0 102 0 -0.7 0 0.1 -1.1 04/29/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 202 0 305 305 102 0 99 0 -0.8 0.1 -0.4 -1.1 04/29/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 101 0 0 0 -1 0.1 -0.4 -1.1 04/29/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 101 0 0 0 -1 0 -0.6 -1.1 04/29/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 100 0 0 0 -1.1 0 -0.6 -1.1 04/29/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 100 0 0 0 -1.1 0 -0.6 -1.1 04/29/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 98 0 0 0 -1.1 0 -0.6 -1.3 04/29/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 97 1 0 0 -1.1 0 -0.6 -1.3 04/29/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 94 1 0 0 -1.1 0 -0.6 -1.3 04/29/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 92 1 0 0 -1.2 0 -0.6 -1.3 04/29/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 89 0 0 0 -1.4 0.1 -0.8 -1.5 04/29/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 87 0 0 0 -1.5 0.2 -1.1 -1.8 04/29/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 85 1 0 0 -1.6 0 -1.1 -1.8 04/29/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 82 1 0 0 -1.6 0 -1.1 -1.8 04/29/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 79 1 0 0 -1.6 0 -1.3 -1.8 04/29/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 74 1 0 0 -1.8 0 -1.1 -2 04/29/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 305 305 70 1 0 0 -1.9 0.1 -1.3 -2.2 04/29/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 66 1 0 0 -1.9 0.1 -1.3 -2 04/29/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 60 2 0 0 -1.8 0.1 -1.3 -2 04/29/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 53 2 0 0 -1.7 0.1 -1.1 -2 04/29/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 41 4 0 0 -1.7 0 -1.1 -2 04/29/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 32 2 0 0 -1.6 0 -1.1 -2 04/29/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 26 2 0 0 -1.6 0.1 -1.1 -2 04/29/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 20 1 0 0 -1.8 0.1 -1.1 -2 04/29/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 16 1 0 0 -1.7 0 -1.3 -2 04/29/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 14 0 0 0 -1.6 0 -1.1 -1.8 04/29/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 1 305 305 12 0 0 0 -1.6 0.1 -1.3 -2 04/29/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 11 0 0 0 -1.6 0.1 -1.3 -1.8 04/29/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 9 0 0 0 -1.6 0.1 -1.1 -2 04/29/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 8 0 0 0 -1.6 0.1 -1.1 -2 04/29/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 7 0 0 0 -1.7 0.1 -1.1 -2 04/29/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 7 0 0 0 -1.6 0.1 -1.1 -1.8 04/29/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 7 0 0 0 -1.5 0.2 -1.1 -1.8 04/29/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 6 0 0 0 -1.4 0.2 -0.8 -1.8 04/29/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 6 0 0 0 -1.4 0.1 -0.8 -1.8 04/29/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 305 305 6 0 0 0 -1.2 0.1 -0.6 -1.8 04/29/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 204 0 305 305 5 0 0 0 -1.2 0.1 -0.8 -1.5 04/29/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 204 1 305 305 5 0 0 0 -1.3 0 -0.8 -1.5 04/29/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 204 1 305 305 5 0 0 0 -1.4 0 -1.1 -1.5 04/29/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 204 0 305 305 5 0 0 0 -1.1 0 -0.6 -1.3 04/29/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 206 2 305 305 4 0 0 0 -1.1 0.1 -0.6 -1.3 04/29/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 210 1 305 305 4 0 0 0 -1.2 0 -0.8 -1.3 04/29/2005 15:50:00 0.4 0 0.4 0.4 0.5 0.5 3.4 0.4 0.4 0 0.4 0.4 237 24 305 305 3 0 3 0 -1 0 -0.6 -1.1 04/29/2005 16:00:00 0.4 0 0.4 0.4 1.8 0.6 3 0.4 0.4 0 0.4 0.4 274 16 305 305 3 0 3 0 -0.7 0.2 -0.4 -1.1 04/29/2005 16:10:00 0.4 0 0.4 0.4 2.5 0.6 3.8 1.1 0.4 0 0.4 0.4 288 9 305 305 2 0 2 0 -0.5 0 -0.4 -0.6 04/29/2005 16:20:00 0.4 0 0.4 0.4 2.1 0.6 3.8 0.7 0.4 0 0.4 0.4 296 12 305 305 2 1 4 0 -0.4 0.1 0.3 -0.6 04/29/2005 16:30:00 0.4 0 0.4 0.4 2.5 0.5 3.8 1.5 0.4 0 0.4 0.4 296 10 305 305 2 1 4 0 -0.3 0 0.3 -0.4 04/29/2005 16:40:00 2.1 1.1 4.2 0.4 2.5 0.8 3.8 0.7 0.4 0 0.4 0.4 295 11 302 305 2 1 4 0 -0.4 0.1 0.1 -0.6 04/29/2005 16:50:00 2.6 0.8 4.2 0.7 2.8 0.7 4.2 1.1 0.4 0 0.4 0.4 298 12 310 305 2 1 4 0 -0.7 0 -0.1 -0.8 04/29/2005 17:00:00 2.4 0.7 3.8 0.4 2.7 0.6 4.2 0.7 0.4 0 0.4 0.4 294 9 287 305 2 1 1 0 -0.7 0 -0.6 -0.8 04/29/2005 17:10:00 2.5 0.7 4.6 1.1 2.6 0.8 4.6 1.1 0.4 0 0.4 0.4 288 16 298 305 2 1 2 0 -0.5 0 -0.4 -0.6 04/29/2005 17:20:00 3 0.6 4.6 1.5 3.2 0.5 4.6 1.5 0.4 0 0.4 0.4 296 10 301 305 2 1 2 0 -0.5 0 -0.4 -0.6 04/29/2005 17:30:00 1.9 0.8 3.4 0.4 2.1 0.7 3.4 0.7 0.4 0 0.4 0.4 289 12 296 305 2 0 4 0 -0.5 0.1 -0.4 -0.8 04/29/2005 17:40:00 1.7 0.7 3.4 0.4 1.9 0.6 3.4 0.4 0.4 0 0.4 0.4 290 18 317 305 2 1 2 0 -0.1 0 0.1 -0.4 04/29/2005 17:50:00 2.6 0.5 3.8 1.1 2.7 0.5 3.8 1.1 0.4 0 0.4 0.4 301 16 302 305 2 1 4 0 -0.4 0.1 0.1 -0.6 04/29/2005 18:00:00 1.1 0.6 3 0.4 1.5 0.5 3 0.7 0.4 0 0.4 0.4 288 17 296 305 2 1 1 0 -0.2 0.1 0.1 -0.6 04/29/2005 18:10:00 1.8 0.7 3.4 0.4 2 0.5 3.4 0.4 0.4 0 0.4 0.4 313 11 316 305 3 1 4 0 0 0 0.3 -0.1 04/29/2005 18:20:00 1.1 0.6 2.6 0.4 1.5 0.5 2.6 0.4 0.4 0 0.4 0.4 332 11 337 305 3 0 2 0 -0.3 0.1 0.1 -0.4 04/29/2005 18:30:00 0.4 0.2 1.5 0.4 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 338 12 341 305 3 0 3 0 -0.3 0 0.1 -0.4 04/29/2005 18:40:00 0.6 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.4 0 0.4 0.4 337 36 327 305 3 1 4 0 0.3 0.2 0.6 -0.1 04/29/2005 18:50:00 0.8 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.4 0 0.4 0.4 309 15 304 305 2 1 3 0 0.2 0 0.6 0.1 04/29/2005 19:00:00 0.5 0.4 2.3 0.4 0.7 0.5 2.6 0.4 0.4 0 0.4 0.4 308 13 308 305 3 1 3 0 0.4 0 1 0.3 04/29/2005 19:10:00 1.4 0.6 2.6 0.4 1.7 0.5 2.6 0.4 0.4 0 0.4 0.4 315 15 333 305 2 1 3 0 0 0.1 0.8 -0.1 04/29/2005 19:20:00 0.7 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0 0.4 0.4 314 30 284 305 2 1 1 0 0 0 0.3 -0.4 04/29/2005 19:30:00 0.8 0.6 2.3 0.4 1.3 0.5 2.3 0.4 0.4 0 0.4 0.4 316 15 310 305 3 1 1 0 -0.2 0 0.1 -0.4 04/29/2005 19:40:00 1.5 0.6 3 0.4 1.8 0.5 3 0.4 0.4 0 0.4 0.4 333 15 339 305 3 0 4 0 -0.1 0 0.1 -0.4 04/29/2005 19:50:00 1.3 0.6 2.6 0.4 1.8 0.5 3 0.7 0.4 0 0.4 0.4 329 13 336 305 4 0 4 0 -0.1 0 0.1 -0.1 04/29/2005 20:00:00 1.1 0.4 1.9 0.4 1.4 0.4 2.3 0.4 0.4 0 0.4 0.4 344 19 340 305 4 0 4 0 -0.1 0 0.3 -0.4 04/29/2005 20:10:00 0.8 0.5 2.3 0.4 1.2 0.5 2.6 0.4 0.4 0 0.4 0.4 2 17 335 305 4 0 4 0 -0.3 0 0.1 -0.4 04/29/2005 20:20:00 0.9 0.6 2.6 0.4 1.2 0.5 2.6 0.4 0.4 0 0.4 0.4 2 22 2 305 4 0 4 0 -0.2 0 0.1 -0.4 04/29/2005 20:30:00 1.5 0.6 2.6 0.4 1.7 0.5 3 0.4 0.4 0 0.4 0.4 3 17 351 305 4 0 4 0 -0.1 0 0.3 -0.4 04/29/2005 20:40:00 2 0.5 3.4 0.4 2.1 0.5 4.2 0.7 0.4 0 0.4 0.4 358 13 14 305 4 0 4 0 -0.3 0.1 0.1 -0.4 04/29/2005 20:50:00 1.1 0.6 2.6 0.4 1.3 0.5 2.3 0.4 0.4 0 0.4 0.4 11 23 28 305 4 0 4 0 -0.1 0.1 0.3 -0.4 04/29/2005 21:00:00 1.5 0.6 3 0.4 1.7 0.5 2.6 0.4 0.4 0 0.4 0.4 35 18 40 305 4 0 4 0 0.2 0 0.3 0.1 04/29/2005 21:10:00 1.6 0.6 3 0.4 1.8 0.5 3 0.4 0.4 0 0.4 0.4 40 17 48 305 4 0 4 0 0 0 0.1 -0.1 04/29/2005 21:20:00 1.6 0.7 3.4 0.4 1.7 0.5 2.6 0.4 0.4 0 0.4 0.4 52 18 57 305 4 0 4 0 0 0 0.3 -0.1 04/29/2005 21:30:00 1.7 0.5 3 0.4 1.9 0.4 3 0.7 0.4 0 0.4 0.4 27 15 25 305 4 0 4 0 -0.1 0 0.1 -0.4 04/29/2005 21:40:00 2.2 0.6 3.4 0.4 2.3 0.4 3.4 1.1 0.4 0 0.4 0.4 37 14 40 305 4 0 4 0 -0.3 0 -0.1 -0.6 04/29/2005 21:50:00 2.3 0.4 3.4 1.5 2.4 0.4 3.4 1.5 0.4 0 0.4 0.4 33 12 20 305 5 0 5 0 -0.4 0.1 0.1 -0.6 04/29/2005 22:00:00 2.2 0.4 3.4 1.1 2.3 0.3 3.4 1.5 0.4 0 0.4 0.4 22 11 33 305 5 0 5 0 -0.5 0.1 0.1 -0.6 04/29/2005 22:10:00 2.1 0.4 3 1.1 2.3 0.4 3.4 1.1 0.4 0 0.4 0.4 21 9 22 305 6 0 6 0 -0.6 0 -0.1 -0.8 04/29/2005 22:20:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.1 0.4 0 0.4 0.4 20 9 22 305 7 0 7 0 -0.7 0.1 -0.4 -1.1 04/29/2005 22:30:00 2.8 0.4 3.8 1.5 2.7 0.5 3.8 1.1 0.4 0 0.4 0.4 18 11 17 305 8 0 8 0 -0.9 0.1 -0.6 -1.1 04/29/2005 22:40:00 3.3 0.6 4.6 1.9 3 0.5 4.6 1.9 0.4 0 0.4 0.4 358 10 341 305 10 0 10 0 -1 0.1 -0.6 -1.3 04/29/2005 22:50:00 3.1 0.4 3.8 1.9 3 0.4 4.2 1.9 0.4 0 0.4 0.4 20 11 6 305 12 1 12 0 -1 0.2 -0.4 -1.3 04/29/2005 23:00:00 3.7 0.4 4.6 3 3.3 0.3 4.2 2.6 0.4 0 0.7 0.4 17 5 19 305 14 0 14 0 -0.7 0.1 -0.1 -0.8 04/29/2005 23:10:00 3.9 0.3 4.6 3.4 3.9 0.3 4.6 3 0.4 0 0.4 0.4 30 6 29 305 16 1 16 0 -0.5 0.2 0.1 -0.8 04/29/2005 23:20:00 4.4 0.3 5.3 3.8 4.1 0.3 4.6 3.4 0.4 0 0.4 0.4 27 6 26 305 18 1 17 0 -0.5 0.1 0.1 -0.6 04/29/2005 23:30:00 4.5 0.3 5.3 3.8 4.4 0.3 5.3 3.8 0.4 0 0.4 0.4 31 3 24 305 21 1 21 0 -0.5 0.1 0.1 -0.6 04/29/2005 23:40:00 4.5 0.3 5.7 3.8 4.6 0.2 4.9 3.8 0.4 0 0.4 0.4 37 4 42 305 23 1 22 0 -0.5 0.1 0.1 -0.6 04/29/2005 23:50:00 4.4 0.2 4.9 3.8 4.4 0.3 4.9 3.8 0.4 0 0.4 0.4 32 3 39 305 26 1 25 0 -0.5 0 0.1 -0.6 04/30/2005 00:00:00 4 0.2 4.6 3.4 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 27 3 30 305 28 1 28 0 -0.6 0 -0.4 -0.6 04/30/2005 00:10:00 4 0.2 4.6 3.4 4 0.2 4.6 3.4 0.4 0 0.4 0.4 28 3 36 305 31 1 30 0 -0.7 0 -0.4 -1.1 04/30/2005 00:20:00 4.1 0.3 4.6 3.4 4 0.2 4.6 3.4 0.4 0 0.4 0.4 25 3 21 305 34 1 34 0 -0.8 0 -0.4 -1.1 04/30/2005 00:30:00 4.2 0.2 4.9 3.8 4.3 0.2 4.9 3.8 0.4 0 0.4 0.4 32 4 36 305 37 1 36 0 -0.8 0 -0.4 -1.1 04/30/2005 00:40:00 4.1 0.2 4.6 3.4 4.1 0.3 4.9 3.4 0.4 0 0.4 0.4 27 5 32 305 41 1 40 0 -0.8 0 -0.4 -1.1 04/30/2005 00:50:00 4.1 0.2 4.6 3.4 3.9 0.2 4.6 3.4 0.4 0 0.4 0.4 26 4 23 305 44 1 45 0 -0.9 0.1 -0.4 -1.1 04/30/2005 01:00:00 4.3 0.3 4.9 3.4 4.4 0.3 5.3 3.4 0.4 0 0.4 0.4 37 5 43 305 48 1 49 0 -0.7 0 -0.1 -1.1 04/30/2005 01:10:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.8 0.4 0 0.4 0.4 36 4 32 305 51 1 52 0 -0.5 0 0.1 -0.6 04/30/2005 01:20:00 4.5 0.3 5.3 3.8 4.6 0.3 5.7 3.8 0.4 0 0.4 0.4 35 5 32 305 55 1 55 0 -0.5 0 0.1 -0.6 04/30/2005 01:30:00 4.8 0.2 5.3 4.2 4.8 0.2 5.3 4.2 0.4 0 0.4 0.4 34 3 36 305 57 1 56 0 -0.5 0 0.1 -0.6 04/30/2005 01:40:00 4.6 0.2 5.3 3.8 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 30 3 36 305 60 1 59 0 -0.6 0 0.1 -0.6 04/30/2005 01:50:00 4.6 0.3 5.3 4.2 4.4 0.2 4.9 3.8 0.4 0 0.4 0.4 30 3 30 305 62 0 62 0 -0.7 0.1 -0.1 -1.1 04/30/2005 02:00:00 5.1 0.3 5.7 4.6 4.9 0.3 5.7 4.2 0.4 0 0.4 0.4 30 3 28 305 64 1 64 0 -0.7 0.1 -0.4 -1.1 04/30/2005 02:10:00 5.3 0.2 5.7 4.9 5.1 0.2 5.7 4.6 0.4 0 0.4 0.4 32 3 32 305 66 0 65 0 -0.7 0.1 -0.4 -1.1 04/30/2005 02:20:00 5.4 0.2 6.1 4.9 5.1 0.3 5.7 4.6 0.4 0 0.4 0.4 27 3 35 305 68 0 67 0 -0.8 0.2 -0.4 -1.1 04/30/2005 02:30:00 5.5 0.2 6.1 4.9 5.2 0.3 5.7 4.6 0.4 0 0.4 0.4 28 6 21 305 69 0 69 0 -1 0.1 -0.4 -1.1 04/30/2005 02:40:00 6.4 0.4 7.2 5.3 6 0.4 6.8 4.9 0.4 0 0.4 0.4 23 4 23 305 71 1 71 0 -0.8 0 -0.4 -1.1 04/30/2005 02:50:00 7 0.3 7.6 6.1 6.6 0.3 7.6 5.7 0.4 0 0.4 0.4 14 3 17 305 73 0 74 0 -0.8 0 -0.4 -1.1 04/30/2005 03:00:00 6.6 0.3 7.2 5.7 6.2 0.3 6.8 5.3 0.4 0 0.4 0.4 14 2 12 305 75 0 74 0 -0.8 0 -0.6 -1.1 04/30/2005 03:10:00 6.8 0.3 7.6 6.1 6.4 0.3 7.2 5.3 0.4 0 0.4 0.4 15 3 14 305 76 0 77 0 -0.8 0 -0.6 -1.1 04/30/2005 03:20:00 6.9 0.3 7.6 6.1 6.5 0.3 7.2 5.3 0.4 0 0.4 0.4 15 3 21 305 78 0 77 0 -0.7 0 -0.6 -0.8 04/30/2005 03:30:00 6.9 0.3 7.6 6.1 6.4 0.3 7.2 5.7 0.4 0 0.4 0.4 16 2 19 305 79 0 79 0 -0.7 0 -0.4 -0.8 04/30/2005 03:40:00 6.9 0.3 7.6 5.7 6.4 0.3 7.2 5.3 0.4 0 0.4 0.4 18 2 17 305 81 0 81 0 -0.8 0 -0.6 -1.1 04/30/2005 03:50:00 7.3 0.4 8.4 6.1 6.9 0.4 7.6 5.7 0.4 0 0.4 0.4 18 2 18 305 82 0 82 0 -0.8 0 -0.6 -0.8 04/30/2005 04:00:00 7.8 0.3 8.4 6.8 7.3 0.3 8.4 6.5 0.4 0 0.4 0.4 17 2 18 305 83 0 83 0 -0.7 0 -0.4 -0.8 04/30/2005 04:10:00 7.7 0.3 8.4 6.8 7.3 0.3 8.4 6.5 0.4 0 0.4 0.4 14 2 13 305 85 0 85 0 -0.7 0 -0.4 -0.6 04/30/2005 04:20:00 7.7 0.3 8.4 6.8 7.3 0.3 8 6.5 0.4 0 0.4 0.4 11 2 11 305 86 0 85 0 -0.7 0 -0.4 -0.8 04/30/2005 04:30:00 7.5 0.4 8.4 6.1 7.1 0.4 8 6.1 0.4 0 0.4 0.4 11 2 12 305 87 0 86 0 -0.8 0 -0.4 -1.1 04/30/2005 04:40:00 7.1 0.4 8 6.1 6.6 0.4 7.6 5.7 0.4 0 0.4 0.4 16 3 14 305 88 0 87 0 -0.8 0.1 -0.4 -1.1 04/30/2005 04:50:00 6.8 0.3 8 6.1 6.3 0.3 7.2 5.3 0.4 0 0.4 0.4 19 3 18 305 88 0 88 0 -0.9 0.1 -0.4 -1.1 04/30/2005 05:00:00 6.6 0.4 7.6 5.7 6.2 0.4 7.2 5.3 0.4 0 0.4 0.4 20 3 19 305 89 0 89 0 -1 0.1 -0.6 -1.1 04/30/2005 05:10:00 7.3 0.4 8.4 6.5 6.9 0.5 8 5.3 0.4 0 0.4 0.4 15 3 15 305 89 0 90 0 -0.9 0 -0.4 -1.1 04/30/2005 05:20:00 7.7 0.4 9.1 6.8 7.4 0.4 8.8 6.1 0.4 0 0.4 0.4 13 2 10 305 90 0 90 0 -0.8 0 -0.4 -1.1 04/30/2005 05:30:00 8.3 0.4 9.5 6.8 7.8 0.5 9.1 6.5 0.4 0 0.4 0.4 14 3 11 305 91 0 91 0 -0.7 0 -0.4 -0.8 04/30/2005 05:40:00 8.2 0.4 9.9 7.6 7.7 0.4 9.1 6.8 0.4 0 0.4 0.4 17 2 19 305 91 0 91 0 -0.6 0 -0.1 -0.6 04/30/2005 05:50:00 7.9 0.4 8.8 6.8 7.3 0.4 8.4 6.1 0.4 0 0.4 0.4 19 2 18 305 92 0 91 0 -0.6 0 -0.1 -0.6 04/30/2005 06:00:00 7.7 0.5 8.8 6.5 7.1 0.5 8.8 5.7 0.4 0 0.4 0.4 18 3 16 305 92 0 92 0 -0.7 0 -0.4 -0.8 04/30/2005 06:10:00 8.5 0.5 9.5 6.8 8 0.6 9.5 6.5 0.4 0 0.4 0.4 16 3 15 305 92 0 93 0 -0.5 0 0.1 -0.6 04/30/2005 06:20:00 9.1 0.4 10.3 8 8.6 0.5 9.9 7.2 0.4 0 0.4 0.4 15 3 16 305 93 0 93 0 -0.3 0 0.1 -0.4 04/30/2005 06:30:00 9.3 0.4 10.3 8 8.7 0.5 9.9 7.2 0.4 0 0.4 0.4 15 2 15 305 93 0 93 0 -0.3 0 0.3 -0.4 04/30/2005 06:40:00 9.1 0.4 10.3 7.6 8.6 0.5 9.9 7.2 0.4 0 0.4 0.4 16 2 15 305 92 0 92 0 -0.1 0 0.1 -0.4 04/30/2005 06:50:00 9.2 0.4 10.3 7.6 8.7 0.4 9.9 7.6 0.4 0 0.4 0.4 15 3 17 305 91 0 92 0 -0.1 0 0.1 -0.1 04/30/2005 07:00:00 8.6 0.5 9.9 7.2 8.1 0.5 9.5 6.8 0.4 0 0.4 0.4 15 3 17 305 90 0 91 0 0 0 0.3 -0.1 04/30/2005 07:10:00 8.6 0.4 9.9 7.2 8.1 0.5 9.1 6.8 0.4 0 0.4 0.4 18 3 11 305 89 0 90 0 0 0 0.3 0.1 04/30/2005 07:20:00 8.7 0.5 9.9 7.2 8.3 0.5 9.5 6.8 0.4 0 0.4 0.4 19 3 21 305 88 0 88 0 0 0 0.6 0.1 04/30/2005 07:30:00 9.1 0.6 11.1 7.6 8.5 0.6 11.1 7.2 0.4 0 0.4 0.4 20 3 21 305 86 0 86 0 0 0 0.6 0.1 04/30/2005 07:40:00 9.3 0.5 10.7 8.4 8.9 0.5 10.7 7.6 0.4 0 0.4 0.4 20 3 24 305 85 0 86 0 0.2 0 0.6 0.1 04/30/2005 07:50:00 8.7 0.5 9.9 7.6 8.2 0.5 9.5 6.8 0.4 0 0.4 0.4 17 3 14 305 84 0 84 0 0 0 0.6 -0.1 04/30/2005 08:00:00 9.3 0.6 11.1 7.6 8.8 0.6 10.3 7.2 0.4 0 0.4 0.4 19 3 24 305 82 0 82 0 0 0.1 0.6 0.1 04/30/2005 08:10:00 9.2 0.6 10.7 7.6 8.8 0.6 10.7 7.2 0.4 0 0.4 0.4 22 3 21 305 81 0 81 0 0.2 0 0.6 0.1 04/30/2005 08:20:00 8.4 0.4 9.1 7.6 8 0.4 8.8 6.5 0.4 0 0.4 0.4 19 3 25 305 79 0 80 0 0 0.1 0.6 -0.1 04/30/2005 08:30:00 8.6 0.5 10.3 7.2 8.1 0.5 9.9 6.8 0.4 0 0.4 0.4 17 3 17 305 78 0 77 0 -0.1 0 0.3 -0.1 04/30/2005 08:40:00 8.7 0.4 9.9 7.2 8.3 0.5 9.5 6.8 0.4 0 0.4 0.4 18 3 21 305 76 0 77 0 0 0 0.6 0.1 04/30/2005 08:50:00 8.5 0.5 9.9 7.2 8.1 0.5 9.1 6.8 0.4 0 0.4 0.4 16 3 13 305 74 1 75 0 0.1 0.1 0.6 0.1 04/30/2005 09:00:00 9 0.6 10.3 7.2 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 18 4 19 305 71 1 72 0 0.2 0 0.6 0.1 04/30/2005 09:10:00 9.4 0.5 10.7 8 9 0.5 10.7 7.2 0.4 0 0.4 0.4 18 3 14 305 67 1 67 0 0.3 0 0.6 0.1 04/30/2005 09:20:00 8.9 0.6 10.7 7.6 8.5 0.6 10.3 6.5 0.4 0 0.4 0.4 21 3 21 305 64 1 65 0 0.3 0 0.8 0.3 04/30/2005 09:30:00 8.1 0.5 9.5 6.8 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 21 3 27 305 60 1 62 0 0.3 0.1 0.8 0.1 04/30/2005 09:40:00 7.5 0.5 8.4 6.1 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 19 3 18 305 55 1 57 0 0.2 0.1 0.6 0.1 04/30/2005 09:50:00 7.7 0.5 9.1 6.1 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 20 3 21 305 51 1 51 0 0.2 0.1 0.8 0.1 04/30/2005 10:00:00 8.6 0.5 10.3 6.8 8.2 0.6 9.9 6.8 0.4 0 0.4 0.4 20 4 22 305 47 1 45 0 0.3 0 1 0.1 04/30/2005 10:10:00 8.7 0.5 9.9 7.2 8.5 0.5 9.9 6.8 0.4 0 0.4 0.4 21 3 26 305 43 1 43 0 0.5 0 1 0.3 04/30/2005 10:20:00 8.7 0.5 10.3 7.2 8.4 0.6 9.9 6.5 0.4 0 0.7 0.4 18 3 17 305 39 1 41 0 0.4 0 1 0.3 04/30/2005 10:30:00 8.8 0.6 10.7 7.6 8.5 0.6 10.3 6.8 0.4 0 0.4 0.4 15 3 17 305 36 1 36 0 0.4 0 1 0.3 04/30/2005 10:40:00 8.5 0.5 9.9 6.8 8.3 0.6 9.9 6.5 0.4 0 0.4 0.4 16 3 14 305 33 0 34 0 0.4 0 1 0.3 04/30/2005 10:50:00 8.9 0.7 10.7 6.8 8.6 0.7 10.7 6.8 0.4 0 0.4 0.4 18 4 16 305 31 1 31 0 0.4 0.1 1 0.3 04/30/2005 11:00:00 8.9 0.6 10.7 7.2 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 19 4 16 305 29 0 29 0 0.6 0.1 1 0.3 04/30/2005 11:10:00 8.9 0.6 10.7 7.2 8.7 0.6 10.7 6.8 0.4 0 0.4 0.4 19 4 17 305 28 0 27 0 0.6 0.2 1 0.3 04/30/2005 11:20:00 9.3 0.6 10.7 7.6 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 21 3 19 305 26 0 27 0 0.6 0.2 1 0.3 04/30/2005 11:30:00 8.5 0.6 9.9 6.8 8.3 0.6 9.5 6.5 0.4 0 0.4 0.4 21 4 20 305 25 0 25 0 0.5 0 1 0.3 04/30/2005 11:40:00 8.5 0.6 9.9 6.8 8.2 0.7 9.9 6.8 0.4 0 0.4 0.4 23 3 26 305 23 0 24 0 0.6 0.1 1 0.3 04/30/2005 11:50:00 8.4 0.5 9.9 6.8 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 23 3 22 305 22 0 22 0 0.5 0.1 1 0.3 04/30/2005 12:00:00 7.9 0.5 9.1 6.5 7.7 0.6 9.1 6.1 0.4 0 0.4 0.4 23 3 17 305 21 0 21 0 0.6 0.1 1 0.3 04/30/2005 12:10:00 7.8 0.4 9.1 6.5 7.5 0.5 8.4 5.7 0.4 0 0.4 0.4 23 3 18 305 20 0 21 0 0.5 0.1 1 0.3 04/30/2005 12:20:00 7.4 0.4 8.4 6.1 7.3 0.5 8.4 5.7 0.4 0 0.4 0.4 20 3 23 305 19 0 19 0 0.4 0.1 1 0.3 04/30/2005 12:30:00 7.2 0.5 8.8 6.1 6.9 0.5 8.4 5.3 0.4 0 0.4 0.4 23 4 23 305 18 0 19 0 0.5 0.1 1 0.3 04/30/2005 12:40:00 6.6 0.5 7.6 5.3 6.4 0.5 7.6 4.6 0.4 0 0.4 0.4 26 4 21 305 18 0 18 0 0.6 0.1 1 0.3 04/30/2005 12:50:00 6.3 0.4 7.6 5.3 6 0.5 7.2 4.2 0.4 0 0.4 0.4 29 4 32 305 17 0 17 0 0.6 0 1 0.3 04/30/2005 13:00:00 6.5 0.4 8 5.7 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 29 3 21 305 16 0 16 0 0.7 0.2 1.3 0.6 04/30/2005 13:10:00 6.4 0.3 7.2 5.7 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 31 3 27 305 15 0 15 0 0.9 0 1.3 0.6 04/30/2005 13:20:00 6.7 0.4 7.6 5.7 6.5 0.4 7.6 5.3 0.4 0 0.4 0.4 28 3 26 305 14 0 14 0 0.9 0.1 1.3 0.6 04/30/2005 13:30:00 6.5 0.4 7.2 5.3 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 30 3 33 305 13 0 14 0 1 0 1.5 0.6 04/30/2005 13:40:00 6.7 0.5 7.6 5.7 6.5 0.5 7.6 5.3 0.4 0 0.4 0.4 30 3 33 305 13 0 13 0 1.2 0.1 1.5 1 04/30/2005 13:50:00 7 0.4 8.4 6.1 6.8 0.4 8 5.7 0.4 0 0.4 0.4 28 4 22 305 12 0 12 0 1.2 0.1 1.5 1 04/30/2005 14:00:00 6.7 0.4 8.4 5.7 6.5 0.5 8 4.9 0.4 0 0.4 0.4 29 4 25 305 12 0 11 0 1.2 0.1 1.5 1 04/30/2005 14:10:00 7 0.5 8.4 5.7 6.6 0.5 8 4.9 0.4 0 0.4 0.4 25 4 21 305 11 0 11 0 1.3 0.1 1.7 1 04/30/2005 14:20:00 7 0.4 8 6.1 6.8 0.5 8 5.7 0.4 0 0.4 0.4 26 3 23 305 11 0 11 0 1.4 0 2 1.3 04/30/2005 14:30:00 7.3 0.5 8.8 6.1 7.1 0.5 8.4 5.3 0.4 0 0.4 0.4 25 3 22 305 10 0 10 0 1.6 0 2.2 1.5 04/30/2005 14:40:00 7.6 0.5 8.8 6.1 7.2 0.6 8.8 6.1 0.4 0 0.4 0.4 24 4 21 305 10 0 10 0 1.6 0 2.2 1.3 04/30/2005 14:50:00 7.8 0.5 9.1 6.5 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 25 4 18 305 9 0 9 0 1.6 0.1 2.2 1.3 04/30/2005 15:00:00 8.4 0.6 9.9 6.5 8 0.7 9.9 5.7 0.4 0 0.4 0.4 23 4 15 305 9 0 8 0 1.7 0.2 2.2 1.5 04/30/2005 15:10:00 8.9 0.5 10.7 7.6 8.6 0.5 9.9 6.8 0.4 0 0.4 0.4 22 3 21 305 8 0 8 0 1.7 0.2 2.2 1.5 04/30/2005 15:20:00 8.6 0.5 9.9 7.2 8.2 0.5 9.5 6.5 0.4 0 0.4 0.4 26 3 26 305 8 0 8 0 1.6 0.1 2.2 1.5 04/30/2005 15:30:00 8.7 0.5 9.9 7.2 8.3 0.5 9.5 6.8 0.4 0 0.4 0.4 27 3 24 305 8 0 8 0 1.6 0.1 2.2 1.3 04/30/2005 15:40:00 9.1 0.5 10.3 8 8.7 0.6 10.3 7.2 0.4 0 0.4 0.4 26 4 18 305 7 0 7 0 1.6 0.1 2.2 1.5 04/30/2005 15:50:00 8.5 0.5 9.9 6.8 8.1 0.5 9.5 6.5 0.4 0 0.4 0.4 25 3 25 305 7 0 7 0 1.6 0.1 2.2 1.3 04/30/2005 16:00:00 8.6 0.5 9.9 7.6 8.2 0.5 9.5 6.8 0.4 0 0.4 0.4 25 4 29 305 7 0 7 0 1.7 0.1 2.2 1.5 04/30/2005 16:10:00 8.5 0.5 9.9 6.8 8 0.5 9.5 6.5 0.4 0 0.4 0.4 24 4 22 305 7 0 7 0 1.7 0.1 2.2 1.5 04/30/2005 16:20:00 8.4 0.6 9.9 6.8 8.1 0.6 9.5 6.5 0.4 0 0.4 0.4 24 4 25 305 6 0 6 0 1.7 0.1 2.2 1.5 04/30/2005 16:30:00 8.2 0.5 9.5 6.8 7.9 0.5 9.1 6.8 0.4 0 0.4 0.4 25 4 24 305 6 0 6 0 1.6 0.1 2.2 1.5 04/30/2005 16:40:00 8.9 0.6 10.3 7.6 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 25 4 23 305 5 0 6 0 1.6 0.1 2.2 1.5 04/30/2005 16:50:00 9.2 0.5 10.7 8 8.9 0.5 10.3 7.6 0.4 0 0.4 0.4 28 3 23 305 5 0 5 0 1.7 0.1 2.2 1.5 04/30/2005 17:00:00 9.4 0.5 11.1 8 9.1 0.5 10.7 7.6 0.4 0 0.4 0.4 29 3 30 305 5 0 5 0 1.7 0.1 2.2 1.5 04/30/2005 17:10:00 9.9 0.6 11.5 8 9.6 0.7 11.8 8 0.4 0 0.4 0.4 28 4 25 305 5 0 5 0 1.7 0.1 2.2 1.5 04/30/2005 17:20:00 9.7 0.5 11.1 8.4 9.3 0.5 10.7 8 0.4 0 0.4 0.4 27 3 30 305 4 0 4 0 1.7 0.1 2.2 1.5 04/30/2005 17:30:00 9.2 0.5 10.7 7.6 8.9 0.5 10.3 7.6 0.4 0 0.4 0.4 29 4 27 305 4 0 4 0 1.6 0.1 2.2 1.5 04/30/2005 17:40:00 8.7 0.5 10.3 7.6 8.4 0.5 9.5 7.2 0.4 0 0.4 0.4 28 3 27 305 4 0 4 0 1.7 0.1 2.2 1.5 04/30/2005 17:50:00 9.1 0.6 10.7 7.2 8.8 0.6 10.7 6.5 0.4 0 0.4 0.4 27 3 25 305 4 0 4 0 1.7 0.1 2.2 1.5 04/30/2005 18:00:00 9.4 0.6 11.1 8 9 0.6 10.7 7.6 0.4 0 0.4 0.4 27 4 33 305 3 0 3 0 1.7 0.1 2.2 1.5 04/30/2005 18:10:00 9.7 0.6 11.1 8 9.4 0.6 11.1 7.6 0.4 0 0.4 0.4 28 4 22 305 3 0 3 0 1.7 0.1 2.2 1.5 04/30/2005 18:20:00 9.8 0.6 11.8 8.4 9.5 0.6 11.1 8 0.4 0 0.4 0.4 26 4 24 305 3 0 3 0 1.7 0.1 2.2 1.5 04/30/2005 18:30:00 9.6 0.6 11.1 8 9.2 0.6 11.1 7.2 0.4 0 0.4 0.4 28 4 31 305 3 0 3 0 1.7 0.1 2.2 1.5 04/30/2005 18:40:00 10.8 0.8 12.6 8.4 10.6 0.8 13 8.4 0.4 0 0.4 0.4 27 3 26 305 3 0 3 0 1.7 0.1 2.2 1.5 04/30/2005 18:50:00 11.5 0.8 13.3 9.1 11.1 0.9 13.7 9.1 0.4 0 0.4 0.4 25 4 19 305 3 0 2 0 1.7 0 2 1.5 04/30/2005 19:00:00 11.4 0.7 13.3 9.5 11 0.7 13 9.1 0.4 0 0.4 0.4 26 4 27 305 3 0 3 0 1.7 0.1 2 1.5 04/30/2005 19:10:00 11.2 0.7 13.3 9.1 11 0.7 13.3 9.1 0.4 0 0.4 0.4 26 4 29 305 3 0 3 0 1.7 0.1 2.2 1.5 04/30/2005 19:20:00 11.8 0.8 14.5 9.1 11.4 0.8 13.7 9.1 0.4 0 0.4 0.4 26 4 21 305 3 0 3 0 1.6 0.1 2.2 1.5 04/30/2005 19:30:00 11.9 0.6 13.7 9.9 11.6 0.7 14.1 9.5 0.4 0 0.4 0.4 27 4 32 305 3 0 3 0 1.6 0 2 1.5 04/30/2005 19:40:00 11.4 0.8 13.3 9.5 11.1 0.7 13.3 9.1 0.4 0 0.4 0.4 28 4 27 305 3 0 3 0 1.6 0 2 1.5 04/30/2005 19:50:00 11.4 0.7 13 9.1 11.1 0.8 13 8.4 0.4 0 0.4 0.4 26 4 23 305 3 0 3 0 1.5 0 2 1.3 04/30/2005 20:00:00 11.3 0.7 13 9.5 11.1 0.8 13.3 8.8 0.4 0 0.4 0.4 27 4 23 305 3 0 3 0 1.5 0 2 1.3 04/30/2005 20:10:00 11.2 0.7 13.3 8.8 11 0.8 13 8.8 0.4 0 0.4 0.4 27 4 30 305 3 0 4 0 1.3 0.1 2 1.3 04/30/2005 20:20:00 11.3 0.8 13.3 9.1 11.1 0.9 14.1 8.8 0.4 0 0.4 0.4 26 4 30 305 3 0 4 0 1.3 0.1 1.7 1 04/30/2005 20:30:00 12.1 0.7 14.9 10.3 11.9 0.8 14.1 9.9 0.4 0 0.4 0.4 24 4 22 305 4 0 4 0 1.3 0.1 1.7 1 04/30/2005 20:40:00 12.3 0.8 14.9 10.3 12.1 0.8 14.5 9.9 0.4 0 0.4 0.4 21 4 24 305 4 0 4 0 1.3 0.2 1.7 1 04/30/2005 20:50:00 12.7 0.9 15.3 10.7 12.6 0.9 15.3 10.3 0.4 0 0.4 0.4 20 4 22 305 4 0 4 0 1.3 0.2 1.7 1 04/30/2005 21:00:00 12.6 0.8 14.9 10.7 12.4 0.9 14.9 10.3 0.4 0 0.4 0.4 19 4 19 305 4 0 4 0 1.2 0.2 1.7 1 04/30/2005 21:10:00 12.6 0.8 14.9 10.7 12.4 0.8 14.5 10.7 0.4 0 0.4 0.4 19 4 18 305 4 0 5 0 1.2 0.1 1.5 1 04/30/2005 21:20:00 12.5 0.8 14.5 10.3 12.4 0.8 14.1 10.3 0.4 0 0.4 0.4 20 4 24 305 5 0 5 0 1.1 0.1 1.5 1 04/30/2005 21:30:00 11.9 0.7 13.7 9.9 11.8 0.8 13.7 9.5 0.4 0 0.4 0.4 22 4 21 305 5 0 5 0 0.9 0.1 1.5 0.8 04/30/2005 21:40:00 11.6 0.6 13 9.9 11.5 0.7 13 9.5 0.4 0 0.4 0.4 22 3 23 305 6 0 6 0 0.8 0.1 1.3 0.6 04/30/2005 21:50:00 10.7 0.7 13 8.4 10.8 0.7 13 9.1 0.4 0 0.4 0.4 22 4 28 305 7 0 8 0 0.7 0.2 1 0.6 04/30/2005 22:00:00 11 0.8 13 9.1 11 0.8 13.7 9.1 0.4 0 0.4 0.4 22 4 21 305 8 0 9 0 0.6 0.1 1 0.6 04/30/2005 22:10:00 11.6 0.7 13.7 9.9 11.7 0.7 13.3 9.9 0.4 0 0.4 0.4 22 4 17 305 10 0 9 0 0.6 0 1 0.6 04/30/2005 22:20:00 12.1 0.8 14.5 10.3 12.2 0.9 14.9 9.9 0.4 0 0.4 0.4 24 4 24 305 12 0 12 0 0.6 0 1 0.6 04/30/2005 22:30:00 12.1 0.9 14.5 9.9 12.2 1 14.9 9.5 0.4 0 0.4 0.4 23 3 21 305 13 0 13 0 0.5 0 1 0.6 04/30/2005 22:40:00 12.3 0.7 14.5 10.7 12.5 0.7 14.1 9.9 0.4 0 0.4 0.4 23 4 26 305 15 0 14 0 0.6 0.1 1 0.6 04/30/2005 22:50:00 12.5 0.8 14.5 10.7 12.6 0.8 14.9 10.3 0.4 0 0.4 0.4 22 4 18 305 16 0 16 0 0.6 0.1 1 0.6 04/30/2005 23:00:00 12.3 0.8 14.9 10.3 12.4 1 15.6 10.3 0.4 0 0.4 0.4 21 4 25 305 17 0 17 0 0.5 0 1 0.6 04/30/2005 23:10:00 12.2 0.8 14.5 9.9 12.3 0.8 14.5 9.5 0.4 0 0.4 0.4 20 4 17 305 17 0 17 0 0.6 0 1 0.6 04/30/2005 23:20:00 12.2 0.7 14.1 9.9 12.1 0.8 13.7 9.5 0.4 0 0.4 0.4 19 4 21 305 18 0 18 0 0.6 0.1 1 0.3 04/30/2005 23:30:00 11.9 0.8 14.5 10.3 11.7 0.8 14.1 9.9 0.4 0 0.4 0.4 22 4 16 305 18 0 18 0 0.6 0.1 1 0.6 04/30/2005 23:40:00 12.2 0.7 14.5 10.3 12.2 0.7 14.5 9.9 0.4 0 0.4 0.4 22 4 17 305 19 0 19 0 0.6 0.1 1.3 0.6 04/30/2005 23:50:00 12.8 1 15.3 9.9 12.4 1 16.1 9.9 0.4 0 0.4 0.4 23 4 17 305 19 0 19 0 0.7 0.1 1.3 0.6 05/01/2005 00:00:00 12.1 0.8 14.9 9.9 11.9 0.9 14.1 9.5 0.4 0 0.4 0.4 24 4 29 305 19 0 19 0 0.9 0 1.3 0.6 05/01/2005 00:10:00 11.2 0.8 13 9.1 11.1 0.8 13.7 9.1 0.4 0 0.4 0.4 23 3 26 305 19 0 19 0 0.8 0.1 1.3 0.6 05/01/2005 00:20:00 11.1 0.7 13 9.1 11 0.8 13.7 9.1 0.4 0 0.4 0.4 23 4 22 305 19 0 19 0 0.8 0.1 1.3 0.6 05/01/2005 00:30:00 11.5 0.7 13.3 9.5 11.3 0.8 13.3 9.1 0.4 0 0.4 0.4 24 4 23 305 19 0 19 0 0.8 0.1 1.3 0.6 05/01/2005 00:40:00 11.9 0.8 14.1 9.9 11.7 0.9 14.5 9.5 0.4 0 0.4 0.4 22 4 19 305 19 0 19 0 0.9 0.2 1.3 0.6 05/01/2005 00:50:00 12.4 1 14.5 9.9 12.2 1 15.3 9.9 0.4 0 0.4 0.4 23 4 26 305 19 0 19 0 0.9 0.2 1.3 0.6 05/01/2005 01:00:00 12.5 0.8 14.5 10.7 12.4 0.8 14.5 10.3 0.4 0 0.4 0.4 23 4 25 305 19 0 19 0 0.9 0.2 1.3 0.6 05/01/2005 01:10:00 12.4 0.8 14.9 10.3 12.3 0.9 14.5 9.9 0.4 0 0.4 0.4 23 4 25 305 19 0 19 0 0.9 0.2 1.3 0.6 05/01/2005 01:20:00 12.4 0.8 14.5 10.7 12.1 0.9 14.9 9.9 0.4 0 0.4 0.4 23 4 26 305 18 0 18 0 0.7 0.2 1.3 0.6 05/01/2005 01:30:00 11.8 0.7 14.5 9.9 11.6 0.8 14.1 9.1 0.4 0 0.4 0.4 22 4 18 305 18 0 18 0 0.6 0.2 1 0.6 05/01/2005 01:40:00 11.3 0.7 13 9.5 11.1 0.7 13.3 9.1 0.4 0 0.4 0.4 19 4 20 305 19 0 19 0 0.6 0.2 1 0.3 05/01/2005 01:50:00 11.4 0.7 13.7 9.1 11.2 0.8 13.3 9.5 0.4 0 0.4 0.4 18 4 14 305 19 0 19 0 0.6 0.1 1 0.3 05/01/2005 02:00:00 11 0.8 13 9.1 10.9 0.8 13 8.8 0.4 0 0.4 0.4 18 3 12 305 19 0 19 0 0.4 0.1 1 0.3 05/01/2005 02:10:00 10.3 0.8 12.2 8.8 10.1 0.7 11.8 8 0.4 0 0.4 0.4 16 4 11 305 19 0 19 0 0.2 0.1 0.8 0.1 05/01/2005 02:20:00 9.7 0.7 11.8 7.6 9.6 0.7 11.5 7.6 0.4 0 0.4 0.4 15 4 16 305 20 0 20 0 0 0 0.6 0.1 05/01/2005 02:30:00 9.6 0.7 11.8 8 9.4 0.7 11.5 8 0.4 0 0.4 0.4 16 4 17 305 21 0 21 0 0 0 0.6 0.1 05/01/2005 02:40:00 9.8 0.7 11.8 8 9.7 0.6 11.5 7.2 0.4 0 0.4 0.4 17 4 16 305 21 0 21 0 0 0 0.6 0.1 05/01/2005 02:50:00 9.8 0.7 11.5 8 9.6 0.6 11.5 7.6 0.4 0 0.4 0.4 18 4 18 305 22 0 22 0 0 0 0.3 -0.1 05/01/2005 03:00:00 10 0.7 12.2 8 9.8 0.8 12.2 7.6 0.4 0 0.4 0.4 18 4 23 305 22 0 22 0 0 0 0.6 0.1 05/01/2005 03:10:00 10.4 0.7 13 8.4 10.1 0.8 13.3 8 0.4 0 0.4 0.4 18 4 15 305 23 0 23 0 0 0 0.6 -0.1 05/01/2005 03:20:00 10.5 0.7 12.2 8.8 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 16 4 18 305 23 0 23 0 0 0 0.3 -0.1 05/01/2005 03:30:00 10.7 0.7 12.2 8.8 10.6 0.7 12.6 8.8 0.4 0 0.4 0.4 15 3 17 305 23 0 23 0 0 0 0.3 -0.1 05/01/2005 03:40:00 9.8 0.8 12.2 8 9.7 0.8 12.2 7.6 0.4 0 0.4 0.4 16 4 16 305 24 0 24 0 0 0 0.3 -0.1 05/01/2005 03:50:00 9.1 0.7 11.5 7.6 9 0.7 10.3 7.2 0.4 0 0.4 0.4 16 4 15 305 24 0 24 0 -0.1 0 0.3 -0.4 05/01/2005 04:00:00 8.6 0.6 10.3 7.2 8.5 0.6 9.9 6.8 0.4 0 0.4 0.4 15 4 22 305 24 0 24 0 -0.2 0 0.3 -0.4 05/01/2005 04:10:00 8.5 0.7 11.1 6.8 8.4 0.8 10.3 6.8 0.4 0 0.4 0.4 13 4 12 305 24 0 24 0 -0.2 0 0.3 -0.4 05/01/2005 04:20:00 9.7 0.8 12.2 7.6 9.6 0.8 11.8 8 0.4 0 0.4 0.4 14 4 17 305 25 0 25 0 -0.1 0 0.3 -0.4 05/01/2005 04:30:00 9.6 0.7 11.5 7.6 9.5 0.7 11.5 7.6 0.4 0 0.4 0.4 17 4 16 305 25 0 25 0 -0.3 0 0.3 -0.4 05/01/2005 04:40:00 9.8 0.6 11.8 8 9.8 0.6 11.5 8 0.4 0 0.4 0.4 16 4 19 305 25 0 25 0 -0.3 0 0.1 -0.4 05/01/2005 04:50:00 9.8 0.8 11.5 8 9.6 0.8 11.8 8 0.4 0 0.4 0.4 14 4 15 305 25 0 25 0 -0.3 0 0.1 -0.4 05/01/2005 05:00:00 9 0.6 11.1 7.2 8.9 0.7 10.7 6.8 0.4 0 0.4 0.4 16 4 17 305 26 0 26 0 -0.3 0.1 0.1 -0.6 05/01/2005 05:10:00 8.7 0.6 10.3 7.2 8.6 0.6 10.7 7.2 0.4 0 0.4 0.4 16 4 12 305 26 0 26 0 -0.4 0 0.1 -0.4 05/01/2005 05:20:00 8.8 0.7 10.7 6.8 8.5 0.8 10.3 6.5 0.4 0 0.4 0.4 19 5 15 305 26 0 26 0 -0.3 0 0.3 -0.4 05/01/2005 05:30:00 8.3 0.7 9.5 6.5 8 0.6 9.5 6.5 0.4 0 0.4 0.4 24 5 14 305 27 0 27 0 -0.3 0 0.3 -0.4 05/01/2005 05:40:00 7.5 0.6 9.5 6.1 7.4 0.6 9.5 6.1 0.4 0 0.4 0.4 31 5 30 305 27 0 27 0 -0.3 0 0.1 -0.4 05/01/2005 05:50:00 6.7 0.5 8 5.3 6.7 0.5 8 5.3 0.4 0 0.4 0.4 36 5 35 305 27 0 27 0 -0.4 0.1 0.1 -0.6 05/01/2005 06:00:00 6.7 0.7 8.8 4.9 6.5 0.6 8.4 4.9 0.4 0 0.4 0.4 35 6 37 305 27 0 27 0 -0.5 0.1 0.1 -0.6 05/01/2005 06:10:00 7.6 0.6 9.1 6.5 7.5 0.6 9.5 6.1 0.4 0 0.4 0.4 29 5 20 305 28 0 28 0 -0.4 0.1 0.1 -0.6 05/01/2005 06:20:00 7.7 0.6 9.9 6.1 7.6 0.6 9.5 6.1 0.4 0 0.4 0.4 30 4 27 305 29 0 29 0 -0.3 0 0.1 -0.4 05/01/2005 06:30:00 8 0.6 10.3 6.8 7.9 0.7 10.3 6.5 0.4 0 0.4 0.4 32 5 29 305 29 0 29 0 -0.3 0 0.1 -0.4 05/01/2005 06:40:00 8.1 0.7 9.5 6.5 8.1 0.7 9.5 6.1 0.4 0 0.4 0.4 34 4 26 305 29 0 29 0 -0.3 0 0.1 -0.4 05/01/2005 06:50:00 8.1 0.7 9.9 6.5 8.1 0.6 9.5 6.1 0.4 0 0.4 0.4 34 4 33 305 29 0 28 0 -0.4 0 0.1 -0.4 05/01/2005 07:00:00 8.2 0.5 9.9 6.8 8.3 0.5 9.9 6.5 0.4 0 0.4 0.4 35 4 33 305 29 0 29 0 -0.4 0 0.1 -0.6 05/01/2005 07:10:00 8.6 0.6 10.3 7.2 8.7 0.6 10.7 6.8 0.4 0 0.4 0.4 37 3 35 305 29 0 29 0 -0.4 0.1 0.1 -0.6 05/01/2005 07:20:00 10.2 1 13 8 10.3 1 13 8.4 0.4 0 0.4 0.4 38 4 41 305 29 0 29 0 -0.5 0 0.1 -0.6 05/01/2005 07:30:00 9.8 0.8 12.2 8.4 9.8 0.9 11.8 8 0.4 0 0.4 0.4 35 4 36 305 29 0 29 0 -0.5 0 0.1 -0.6 05/01/2005 07:40:00 9.7 1.2 13 6.8 9.7 1.3 13 6.8 0.4 0 0.4 0.4 37 9 32 305 30 0 29 0 -0.8 0.2 -0.4 -1.1 05/01/2005 07:50:00 9.7 0.7 11.5 8 9.6 0.7 11.8 8 0.4 0 0.4 0.4 36 4 40 305 31 0 31 0 -1.1 0.1 -0.6 -1.1 05/01/2005 08:00:00 11.2 2.2 15.6 6.5 11.2 2.2 16.1 6.8 0.4 0 0.4 0.4 38 6 38 305 32 0 32 0 -1.1 0 -0.6 -1.3 05/01/2005 08:10:00 12.8 1.2 15.6 9.5 12.7 1.3 15.6 8.8 0.4 0 0.4 0.4 39 4 36 305 32 0 32 0 -1.2 0 -0.6 -1.5 05/01/2005 08:20:00 13.6 1 15.6 11.5 13.4 1 16.1 11.5 0.4 0 0.4 0.4 36 4 33 305 33 0 33 0 -1.4 0 -0.8 -1.5 05/01/2005 08:30:00 12.8 1.1 15.6 9.9 12.6 1.2 15.6 9.9 0.4 0 0.4 0.4 36 5 37 305 34 0 34 0 -1.4 0 -0.8 -1.5 05/01/2005 08:40:00 12.1 0.8 14.5 9.9 12 0.9 14.1 9.9 0.4 0 0.4 0.4 35 3 34 305 35 0 36 0 -1.4 0 -1.1 -1.5 05/01/2005 08:50:00 12.9 1 14.9 10.7 12.7 1 14.9 9.5 0.4 0 0.4 0.4 34 4 41 305 37 0 37 0 -1.5 0.1 -1.1 -1.5 05/01/2005 09:00:00 13.4 1 16.1 11.1 13.3 1 16.1 10.7 0.4 0 0.4 0.4 32 5 25 305 38 0 38 0 -1.4 0.1 -1.1 -1.5 05/01/2005 09:10:00 12.8 1.1 16.8 10.7 12.7 1.2 16.8 10.3 0.4 0 0.4 0.4 32 5 39 305 39 0 39 0 -1.4 0.1 -0.8 -1.5 05/01/2005 09:20:00 12.8 1.3 15.6 9.9 12.6 1.2 15.6 9.9 0.4 0 0.4 0.4 31 4 35 305 40 0 40 0 -1.4 0.1 -0.8 -1.5 05/01/2005 09:30:00 12.5 0.7 14.1 10.3 12.3 0.8 14.1 9.9 0.4 0 0.4 0.4 29 4 25 305 41 0 42 0 -1.2 0 -0.6 -1.3 05/01/2005 09:40:00 14 1.2 17.2 11.5 13.7 1.4 17.6 10.7 0.4 0 0.4 0.4 28 4 26 305 42 0 42 0 -1.4 0.2 -0.6 -1.8 05/01/2005 09:50:00 14.2 1.2 17.2 11.1 14 1.4 17.2 9.9 0.4 0 0.4 0.4 27 5 29 305 42 0 42 0 -1.4 0 -0.8 -1.5 05/01/2005 10:00:00 14 1.1 16.8 11.1 13.8 1.2 17.2 11.1 0.4 0 0.4 0.4 30 4 26 305 42 0 42 0 -1.4 0 -1.1 -1.5 05/01/2005 10:10:00 13.9 1.3 17.2 11.1 13.6 1.4 16.8 10.7 0.4 0 0.4 0.4 30 4 31 305 43 0 43 0 -1.4 0 -1.1 -1.5 05/01/2005 10:20:00 14.3 1.1 17.6 11.8 14.1 1.1 16.8 10.7 0.4 0 0.4 0.4 29 5 23 305 43 0 42 0 -1.4 0 -1.1 -1.5 05/01/2005 10:30:00 15.2 1 17.2 12.6 14.9 1.1 17.9 11.8 0.4 0 0.4 0.4 31 4 27 305 42 0 42 0 -1.3 0 -1.1 -1.3 05/01/2005 10:40:00 14.7 1 16.8 11.8 14.3 1.2 17.2 11.5 0.4 0 0.4 0.4 33 5 29 305 42 0 42 0 -1.2 0 -1.1 -1.3 05/01/2005 10:50:00 14.1 1.2 16.8 10.7 13.8 1.3 16.8 9.5 0.4 0 0.4 0.4 35 4 29 305 41 0 41 0 -1.1 0 -0.6 -1.3 05/01/2005 11:00:00 15.4 1.1 17.9 12.2 15.1 1.2 17.9 11.5 0.4 0 0.4 0.4 34 5 33 305 40 0 41 0 -1.1 0 -0.6 -1.3 05/01/2005 11:10:00 16.2 1.3 18.7 12.2 15.9 1.3 18.7 12.2 0.4 0 0.4 0.4 37 4 36 305 39 0 39 0 -1.1 0 -0.6 -1.3 05/01/2005 11:20:00 15.7 1.1 17.9 12.6 15.4 1.2 17.9 11.8 0.4 0 0.4 0.4 38 4 36 305 38 0 39 0 -1.1 0 -0.6 -1.3 05/01/2005 11:30:00 15.9 1.2 19.1 12.6 15.6 1.3 19.1 11.1 0.4 0 0.4 0.4 35 4 33 305 38 0 38 0 -1.1 0 -0.6 -1.3 05/01/2005 11:40:00 15.8 1.3 19.5 12.2 15.5 1.4 19.9 12.2 0.4 0 0.4 0.4 35 4 38 305 37 0 37 0 -1.1 0 -0.6 -1.3 05/01/2005 11:50:00 16.2 1.3 19.1 12.2 15.7 1.3 18.7 11.8 0.4 0 0.4 0.4 34 5 40 305 36 0 36 0 -1.1 0 -0.6 -1.1 05/01/2005 12:00:00 15.2 1.5 18.3 11.5 14.8 1.6 18.3 10.7 0.4 0 0.4 0.4 36 4 40 305 35 0 36 0 -1.1 0 -0.6 -1.3 05/01/2005 12:10:00 15 1.3 19.1 11.5 14.7 1.3 19.5 11.1 0.4 0 0.4 0.4 34 6 33 305 34 0 34 0 -1.1 0 -0.6 -1.3 05/01/2005 12:20:00 14.8 1.3 17.9 11.8 14.5 1.4 17.9 11.1 0.4 0 0.4 0.4 37 5 39 305 34 0 34 0 -1.1 0.1 -0.6 -1.3 05/01/2005 12:30:00 13.7 1 16.1 11.1 13.5 1 16.1 10.7 0.4 0 0.4 0.4 35 5 36 305 35 0 35 0 -1.1 0.1 -0.6 -1.1 05/01/2005 12:40:00 14.2 1.3 17.6 11.8 14 1.3 17.6 11.1 0.4 0 0.4 0.4 35 4 38 305 35 0 35 0 -1.1 0.1 -0.6 -1.1 05/01/2005 12:50:00 14.8 1.2 17.6 11.1 14.6 1.3 17.6 11.5 0.4 0 0.4 0.4 38 4 43 305 35 0 35 0 -1.1 0.1 -0.6 -1.1 05/01/2005 13:00:00 15.6 1.1 17.9 12.6 15.3 1.2 17.9 11.8 0.4 0 0.4 0.4 36 4 33 305 34 0 34 0 -1.1 0.1 -0.6 -1.3 05/01/2005 13:10:00 14.8 1.2 17.9 12.2 14.5 1.3 17.6 11.8 0.4 0 0.4 0.4 38 5 40 305 35 0 35 0 -1 0.1 -0.4 -1.1 05/01/2005 13:20:00 15.8 1.3 18.7 12.2 15.3 1.3 18.3 11.5 0.4 0 0.4 0.4 34 4 35 305 35 0 35 0 -1 0.1 -0.4 -1.1 05/01/2005 13:30:00 16.3 1.2 19.5 12.2 15.9 1.2 19.1 11.8 0.4 0 0.4 0.4 35 4 34 305 34 0 34 0 -1 0.1 -0.4 -1.1 05/01/2005 13:40:00 16.3 1.2 19.5 13.3 16.1 1.3 19.5 13.3 0.4 0 0.4 0.4 35 4 35 305 34 0 34 0 -1 0.1 -0.4 -1.1 05/01/2005 13:50:00 16.1 1.1 18.3 13.3 15.7 1.1 18.3 13 0.4 0 0.4 0.4 35 5 29 305 34 0 34 0 -0.9 0 -0.4 -1.1 05/01/2005 14:00:00 16.3 1.2 20.2 12.6 16.1 1.3 19.9 12.6 0.4 0 0.4 0.4 38 4 37 305 34 0 34 0 -0.9 0 -0.4 -1.1 05/01/2005 14:10:00 16.1 1.5 20.2 11.8 15.7 1.5 19.9 11.1 0.4 0 0.4 0.4 35 4 36 305 34 0 34 0 -0.8 0 -0.4 -1.1 05/01/2005 14:20:00 16.5 1.1 19.5 12.6 16.2 1.2 19.9 12.6 0.4 0 0.4 0.4 36 4 41 305 33 0 33 0 -0.8 0 -0.4 -1.1 05/01/2005 14:30:00 15.2 1.5 18.3 11.8 14.9 1.5 19.1 11.5 0.4 0 0.4 0.4 35 5 33 305 33 0 33 0 -0.8 0 -0.4 -1.1 05/01/2005 14:40:00 15.6 1.3 19.1 12.6 15.2 1.3 18.7 12.2 0.4 0 0.4 0.4 37 4 36 305 33 0 33 0 -0.8 0 -0.6 -1.1 05/01/2005 14:50:00 15.2 1.2 18.3 12.2 15 1.2 18.7 11.5 0.4 0 0.4 0.4 38 4 45 305 33 0 33 0 -0.8 0 -0.4 -0.8 05/01/2005 15:00:00 15.1 1.4 18.7 11.8 14.8 1.5 18.3 11.5 0.4 0 0.4 0.4 38 5 37 305 33 0 33 0 -0.8 0 -0.6 -1.1 05/01/2005 15:10:00 13.1 1.1 16.4 10.7 12.9 1.1 16.1 10.3 0.4 0 0.4 0.4 40 4 38 305 33 0 33 0 -0.7 0 -0.6 -0.8 05/01/2005 15:20:00 13.4 0.9 15.6 11.5 13.1 1 15.3 10.7 0.4 0 0.4 0.4 38 4 40 305 33 0 33 0 -0.7 0 -0.6 -0.8 05/01/2005 15:30:00 13.7 0.8 16.4 11.5 13.5 1 16.1 11.1 0.4 0 0.4 0.4 36 4 33 305 33 0 33 0 -0.7 0 -0.6 -0.8 05/01/2005 15:40:00 13.1 1 15.6 11.1 12.9 1 14.9 10.7 0.4 0 0.4 0.4 38 5 40 305 33 0 33 0 -0.7 0 -0.6 -0.8 05/01/2005 15:50:00 13 1 15.3 11.1 12.7 1.1 15.6 10.3 0.4 0 0.4 0.4 40 4 41 305 33 0 33 0 -0.7 0 -0.6 -0.8 05/01/2005 16:00:00 13.4 1 16.1 10.7 13.2 1 15.6 10.7 0.4 0 0.4 0.4 38 5 42 305 33 0 32 0 -0.7 0 -0.6 -0.8 05/01/2005 16:10:00 13.8 0.8 16.4 11.5 13.7 1 16.1 11.1 0.4 0 0.4 0.4 43 4 46 305 33 0 33 0 -0.7 0 -0.4 -0.8 05/01/2005 16:20:00 13.3 1.4 16.8 11.1 13.1 1.4 16.8 10.7 0.4 0 0.4 0.4 40 4 37 305 33 0 33 0 -0.7 0 -0.6 -0.8 05/01/2005 16:30:00 14.2 0.8 16.1 11.8 14 1 16.1 11.1 0.4 0 0.4 0.4 44 4 40 305 32 0 33 0 -0.6 0 0.1 -0.8 05/01/2005 16:40:00 14.1 1 16.1 11.1 13.9 1.1 16.1 10.3 0.4 0 0.4 0.4 40 4 41 305 32 0 32 0 -0.8 0 -0.1 -1.1 05/01/2005 16:50:00 15.5 1.1 17.2 12.2 15.1 1.2 17.2 10.7 0.4 0 0.4 0.4 39 5 32 305 33 0 33 0 -0.8 0 -0.4 -1.1 05/01/2005 17:00:00 14 0.8 16.1 11.8 13.7 1 16.1 11.1 0.4 0 0.4 0.4 46 4 46 305 33 0 33 0 -0.7 0 -0.4 -0.8 05/01/2005 17:10:00 15.6 1 17.6 13 15.4 1 17.2 12.2 0.4 0 0.4 0.4 38 5 35 305 34 0 34 0 -0.8 0 -0.4 -0.8 05/01/2005 17:20:00 13.6 0.7 15.3 11.8 13.4 0.8 15.3 11.1 0.4 0 0.4 0.4 40 4 39 305 34 0 34 0 -0.7 0 -0.4 -0.8 05/01/2005 17:30:00 14.4 0.7 16.4 12.6 14.2 0.9 16.1 11.8 0.4 0 0.4 0.4 38 3 38 305 35 0 34 0 -0.8 0 -0.4 -0.8 05/01/2005 17:40:00 14.3 1 16.8 11.5 14.2 1.1 16.4 11.5 0.4 0 0.4 0.4 38 3 35 305 35 0 35 0 -0.8 0 -0.4 -1.1 05/01/2005 17:50:00 14.5 0.9 16.8 12.2 14.2 1 16.8 11.8 0.4 0 0.4 0.4 41 4 42 305 36 0 35 0 -0.8 0 -0.4 -0.8 05/01/2005 18:00:00 13.3 0.7 14.9 11.1 13 0.9 15.6 10.3 0.4 0 0.4 0.4 37 4 36 305 36 0 36 0 -0.8 0 -0.4 -1.1 05/01/2005 18:10:00 13.2 1 15.3 10.7 13.1 1.1 15.3 10.3 0.4 0 0.4 0.4 41 4 30 305 37 0 36 0 -0.8 0 -0.4 -1.1 05/01/2005 18:20:00 12.5 0.6 14.1 10.7 12.3 0.7 14.1 10.3 0.4 0 0.4 0.4 43 3 39 305 37 0 37 0 -0.8 0 -0.4 -1.1 05/01/2005 18:30:00 12.7 1 14.9 9.9 12.5 1.1 15.3 9.9 0.4 0 0.4 0.4 42 4 38 305 38 0 38 0 -0.8 0.1 -0.4 -1.1 05/01/2005 18:40:00 13.7 0.9 15.6 11.5 13.4 1 15.6 10.7 0.4 0 0.4 0.4 44 4 49 305 39 0 39 0 -0.8 0.1 -0.4 -1.1 05/01/2005 18:50:00 13.7 0.8 15.6 11.1 13.6 0.8 15.3 10.7 0.4 0 0.4 0.4 39 5 36 305 39 0 39 0 -0.9 0 -0.4 -1.1 05/01/2005 19:00:00 13.2 0.9 15.6 11.1 13.1 1 15.6 9.9 0.4 0 0.4 0.4 40 4 35 305 40 0 40 0 -1 0.1 -0.4 -1.1 05/01/2005 19:10:00 13 0.8 16.1 11.5 12.8 0.9 15.3 10.7 0.4 0 0.4 0.4 37 4 40 305 41 0 41 0 -1 0.1 -0.4 -1.1 05/01/2005 19:20:00 13.1 0.9 15.3 11.1 13 1 15.6 10.3 0.4 0 0.4 0.4 39 4 42 305 42 0 41 0 -1 0.1 -0.6 -1.1 05/01/2005 19:30:00 13.4 1 15.6 10.7 13.3 1.1 15.6 10.7 0.4 0 0.4 0.4 39 3 33 305 43 0 43 0 -1 0.1 -0.6 -1.1 05/01/2005 19:40:00 13.9 0.8 15.3 11.8 13.8 0.9 15.6 11.5 0.4 0 0.4 0.4 42 3 45 305 43 0 43 0 -1.1 0.1 -0.6 -1.1 05/01/2005 19:50:00 13.3 0.6 15.3 11.8 13.2 0.7 15.3 11.5 0.4 0 0.4 0.4 42 3 36 305 44 0 44 0 -1.1 0 -0.6 -1.1 05/01/2005 20:00:00 13.4 0.9 15.3 10.7 13.1 1 15.3 10.7 0.4 0 0.4 0.4 38 5 33 305 45 0 45 0 -1.1 0 -0.6 -1.1 05/01/2005 20:10:00 14 0.7 15.3 11.5 13.7 0.8 15.3 11.5 0.4 0 0.4 0.4 42 3 40 305 46 0 46 0 -1.1 0 -0.6 -1.1 05/01/2005 20:20:00 13.7 0.8 15.6 11.5 13.5 0.9 16.1 10.7 0.4 0 0.4 0.4 41 3 39 305 47 0 47 0 -1.1 0 -0.6 -1.1 05/01/2005 20:30:00 13 1.2 15.6 10.3 12.7 1.3 15.3 9.9 0.4 0 0.4 0.4 39 4 35 305 49 0 49 0 -1.1 0 -1.1 -1.3 05/01/2005 20:40:00 13.2 1 15.3 10.7 13 1 15.3 9.9 0.4 0 0.4 0.4 35 4 35 305 50 0 50 0 -1.1 0 -0.8 -1.3 05/01/2005 20:50:00 14 0.7 16.1 11.5 13.7 0.8 15.6 11.5 0.4 0 0.4 0.4 38 4 39 305 51 0 51 0 -1.1 0 -0.8 -1.3 05/01/2005 21:00:00 12.9 0.8 14.9 11.1 12.6 0.9 14.9 10.3 0.4 0 0.4 0.4 39 4 39 305 52 0 53 0 -1.1 0 -0.6 -1.3 05/01/2005 21:10:00 13.2 1 15.6 11.5 13.1 1 15.6 10.3 0.4 0 0.4 0.4 39 3 46 305 53 0 53 0 -1.1 0.1 -0.6 -1.3 05/01/2005 21:20:00 13.6 1 15.6 10.3 13.5 1.1 15.6 9.9 0.4 0 0.4 0.4 38 3 35 305 55 0 54 0 -1.1 0.1 -0.6 -1.3 05/01/2005 21:30:00 14 0.8 15.6 11.5 13.8 0.8 15.6 11.8 0.4 0 0.4 0.4 35 3 36 305 56 0 56 0 -1.1 0.1 -0.6 -1.3 05/01/2005 21:40:00 13.6 0.9 16.1 11.8 13.4 1 16.1 11.1 0.4 0 0.4 0.4 38 4 40 305 57 0 57 0 -1.1 0.1 -0.6 -1.3 05/01/2005 21:50:00 13.7 1 16.1 11.1 13.5 1 15.6 10.7 0.4 0 0.4 0.4 38 4 37 305 58 0 58 0 -1.2 0 -0.6 -1.3 05/01/2005 22:00:00 13.8 1 16.1 11.1 13.6 1.2 16.1 9.9 0.4 0 0.4 0.4 36 3 37 305 59 0 59 0 -1.1 0 -0.6 -1.3 05/01/2005 22:10:00 13.1 1.1 16.1 10.7 12.8 1.2 16.1 10.3 0.4 0 0.4 0.4 39 4 39 305 61 0 62 0 -1.1 0 -0.6 -1.3 05/01/2005 22:20:00 14 0.9 15.6 11.1 13.9 1 15.6 10.7 0.4 0 0.4 0.4 40 3 38 305 62 0 62 0 -1.2 0.1 -0.6 -1.3 05/01/2005 22:30:00 14 1 15.6 11.5 13.8 1 16.1 11.5 0.4 0 0.4 0.4 39 4 36 305 63 0 63 0 -1.3 0.1 -0.6 -1.3 05/01/2005 22:40:00 13.3 1.1 15.6 10.7 13.2 1.1 16.1 10.3 0.4 0 0.4 0.4 38 5 43 305 65 0 64 0 -1.3 0 -0.6 -1.3 05/01/2005 22:50:00 13.3 0.8 15.3 11.5 13.2 0.9 15.3 10.7 0.4 0 0.4 0.4 41 4 45 305 66 1 65 0 -1.3 0 -0.8 -1.3 05/01/2005 23:00:00 13.2 0.9 15.3 10.7 13.1 1 15.3 9.5 0.4 0 0.4 0.4 41 4 40 305 68 0 68 0 -1.4 0 -0.8 -1.5 05/01/2005 23:10:00 13.3 0.7 14.9 11.5 13.1 0.8 14.9 10.7 0.4 0 0.4 0.4 42 3 38 305 70 0 69 0 -1.4 0.1 -0.8 -1.5 05/01/2005 23:20:00 13.2 1 14.9 9.9 13 1 14.9 9.9 0.4 0 0.4 0.4 37 4 38 305 72 0 72 0 -1.4 0.1 -1.1 -1.8 05/01/2005 23:30:00 13.3 0.8 14.9 10.7 13.1 0.9 15.3 10.3 0.4 0 0.4 0.4 39 4 35 305 73 0 74 0 -1.4 0 -1.1 -1.5 05/01/2005 23:40:00 12.9 0.9 15.3 10.3 12.7 1 15.3 10.3 0.4 0 0.4 0.4 40 4 40 305 75 0 74 0 -1.4 0 -0.8 -1.5 05/01/2005 23:50:00 11.7 0.9 13.7 9.1 11.6 1 14.1 9.1 0.4 0 0.4 0.4 40 5 41 305 76 0 77 0 -1.4 0 -1.1 -1.5 05/02/2005 00:00:00 12.3 1.1 14.5 8.8 12.1 1.1 14.1 8.8 0.4 0 0.4 0.4 35 4 31 305 77 0 77 0 -1.4 0 -1.1 -1.5 05/02/2005 00:10:00 11.4 0.9 13.3 8.8 11.3 0.9 14.1 9.1 0.4 0 0.4 0.4 41 4 43 305 78 0 79 0 -1.4 0 -1.1 -1.5 05/02/2005 00:20:00 11.3 1.2 13.3 8 11.2 1.2 13.3 8 0.4 0 0.4 0.4 37 4 36 305 80 0 80 0 -1.4 0 -1.1 -1.5 05/02/2005 00:30:00 11.8 0.6 13.3 9.5 11.7 0.7 13.7 9.1 0.4 0 0.4 0.4 38 4 41 305 81 0 80 0 -1.5 0 -1.1 -1.5 05/02/2005 00:40:00 11.2 0.8 13 9.1 11.1 0.8 13.3 8.8 0.4 0 0.4 0.4 38 4 33 305 82 0 81 0 -1.5 0 -1.1 -1.5 05/02/2005 00:50:00 10.9 0.7 13 8.8 10.7 0.8 12.6 8.4 0.4 0 0.4 0.4 39 4 36 305 82 0 83 0 -1.4 0 -1.1 -1.5 05/02/2005 01:00:00 10.9 0.7 12.2 8.4 10.8 0.7 12.6 7.6 0.4 0 0.4 0.4 33 4 31 305 83 0 83 0 -1.4 0 -1.1 -1.5 05/02/2005 01:10:00 11.1 0.8 13 8.4 11 1 13.3 8.8 0.4 0 0.4 0.4 34 5 30 305 84 0 84 0 -1.4 0 -1.1 -1.5 05/02/2005 01:20:00 10.7 0.8 11.8 8.4 10.7 0.9 12.2 8.4 0.4 0 0.4 0.4 39 4 45 305 85 0 84 0 -1.4 0 -1.1 -1.5 05/02/2005 01:30:00 11.7 0.6 13 9.5 11.6 0.8 13.3 8.8 0.4 0 0.4 0.4 35 5 35 305 85 0 85 0 -1.5 0.1 -1.1 -1.8 05/02/2005 01:40:00 10.9 0.8 12.6 8.8 10.9 0.9 13 8.8 0.4 0 0.4 0.4 38 5 37 305 85 0 85 0 -1.6 0 -1.1 -1.8 05/02/2005 01:50:00 10.4 0.7 12.2 8.8 10.4 0.7 12.2 8.4 0.4 0 0.4 0.4 41 5 47 305 86 0 85 0 -1.6 0.1 -1.1 -1.8 05/02/2005 02:00:00 11 0.7 12.6 8.8 11 0.8 13 8.8 0.4 0 0.4 0.4 39 5 36 305 86 0 86 0 -1.6 0.1 -1.1 -1.8 05/02/2005 02:10:00 11.1 0.7 12.6 8.4 11.2 0.8 13 9.1 0.4 0 0.4 0.4 37 3 37 305 86 0 86 0 -1.6 0 -1.1 -1.8 05/02/2005 02:20:00 10.2 0.7 11.8 7.6 10.3 0.8 12.2 7.6 0.4 0 0.4 0.4 37 9 40 305 86 0 86 0 -1.6 0 -1.1 -1.8 05/02/2005 02:30:00 9.4 1 11.8 6.1 9.5 1 11.8 6.5 0.4 0 0.4 0.4 49 0 48 305 87 0 87 0 -1.6 0 -1.1 -1.8 05/02/2005 02:40:00 9.5 1 11.8 7.2 9.6 1 12.2 7.2 0.4 0 0.4 0.4 49 0 48 305 87 0 87 0 -1.7 0 -1.1 -1.8 05/02/2005 02:50:00 10.2 0.8 12.2 7.2 10.2 1 12.2 7.2 0.4 0 0.4 0.4 49 0 48 305 87 0 87 0 -1.8 0 -1.3 -2 05/02/2005 03:00:00 9.9 0.7 12.2 8 9.9 0.8 12.6 7.6 0.4 0 0.4 0.4 49 0 48 305 88 0 87 0 -1.6 0 -1.3 -2 05/02/2005 03:10:00 10.3 0.7 11.8 8.4 10.4 0.8 12.6 8.4 0.4 0 0.4 0.4 49 0 48 305 88 0 88 0 -1.7 0 -1.3 -2 05/02/2005 03:20:00 9.8 0.8 11.8 7.6 9.9 0.8 11.8 7.2 0.4 0 0.4 0.4 49 0 48 305 88 0 88 0 -1.6 0 -1.3 -1.8 05/02/2005 03:30:00 9.9 0.8 11.8 8.4 10.1 0.9 11.8 8 0.4 0 0.4 0.4 48 0 48 305 88 0 88 0 -1.7 0 -1.3 -2 05/02/2005 03:40:00 10.4 0.7 11.8 8.4 10.3 0.7 12.2 8 0.4 0 0.4 0.4 48 0 48 305 89 0 89 0 -1.8 0 -1.3 -2 05/02/2005 03:50:00 10.2 0.7 11.8 8 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 49 0 48 305 89 0 89 0 -1.8 0 -1.3 -2 05/02/2005 04:00:00 10.3 0.8 11.8 8.4 10.4 0.8 12.2 7.6 0.4 0 0.4 0.4 49 0 48 305 89 0 89 0 -1.8 0 -1.3 -2 05/02/2005 04:10:00 10 0.7 11.8 8.4 10.1 0.7 11.8 8 0.4 0 0.4 0.4 49 0 48 305 89 0 90 0 -1.8 0 -1.5 -2 05/02/2005 04:20:00 9.9 0.6 11.1 8 9.8 0.6 11.5 8 0.4 0 0.4 0.4 48 0 48 305 89 0 90 0 -1.8 0 -1.5 -2 05/02/2005 04:30:00 9.7 0.6 11.1 8 9.8 0.7 11.5 7.6 0.4 0 0.4 0.4 48 0 48 305 89 0 90 0 -1.8 0 -1.8 -2 05/02/2005 04:40:00 8.9 0.8 11.1 6.5 9 0.9 10.7 6.5 0.4 0 0.4 0.4 48 0 48 305 89 0 90 0 -1.8 0 -1.3 -2 05/02/2005 04:50:00 10.1 0.8 11.8 7.6 10.3 0.7 11.8 8.4 0.4 0 0.4 0.4 48 0 48 305 89 0 90 0 -1.9 0 -1.3 -2 05/02/2005 05:00:00 8.7 0.9 11.1 6.1 8.8 0.9 10.7 6.5 0.4 0 0.4 0.4 48 0 48 305 89 0 90 0 -1.9 0 -1.8 -2 05/02/2005 05:10:00 8.5 1.2 11.1 6.1 8.6 1.1 11.1 6.5 0.4 0 0.4 0.4 48 0 48 305 90 0 90 0 -1.8 0 -1.3 -2 05/02/2005 05:20:00 8.9 0.8 11.5 7.2 9 0.8 11.1 6.8 0.4 0 0.4 0.4 48 0 48 305 90 0 90 0 -1.8 0 -1.3 -2 05/02/2005 05:30:00 9.6 0.9 11.5 7.6 9.6 0.9 11.5 6.8 0.4 0 0.4 0.4 48 0 48 305 90 0 90 0 -1.7 0 -1.3 -2 05/02/2005 05:40:00 9.4 0.6 11.1 7.6 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 48 0 48 305 90 0 91 0 -1.7 0 -1.3 -2 05/02/2005 05:50:00 9.8 0.7 11.5 8.4 10 0.8 11.8 8 0.4 0 0.4 0.4 48 0 48 305 90 0 91 0 -1.7 0 -1.8 -1.8 05/02/2005 06:00:00 10.5 0.9 12.6 8 10.6 1 13 8 0.4 0 0.4 0.4 48 0 48 305 90 0 90 0 -1.7 0 -1.3 -2 05/02/2005 06:10:00 9.4 0.6 11.1 7.6 9.5 0.7 11.5 8 0.4 0 0.4 0.4 48 0 48 305 90 0 90 0 -1.7 0 -1.3 -1.8 05/02/2005 06:20:00 9.4 0.7 11.1 8 9.4 0.8 11.1 7.2 0.4 0 0.4 0.4 48 0 48 305 90 0 90 0 -1.7 0 -1.3 -1.8 05/02/2005 06:30:00 9.8 0.7 11.1 8 9.9 0.7 11.5 7.6 0.4 0 0.4 0.4 48 0 48 305 89 0 90 0 -1.7 0 -1.3 -1.8 05/02/2005 06:40:00 9.5 0.6 11.1 8 9.6 0.7 11.1 7.6 0.4 0 0.4 0.4 49 0 48 305 89 0 90 0 -1.7 0 -1.3 -1.8 05/02/2005 06:50:00 8.5 0.4 9.5 7.2 8.6 0.5 9.9 6.8 0.4 0 0.4 0.4 48 0 48 305 89 0 89 0 -1.6 0 -1.3 -1.8 05/02/2005 07:00:00 7.9 0.6 9.5 6.5 7.9 0.7 9.5 6.5 0.4 0 0.4 0.4 48 0 48 305 88 0 88 0 -1.5 0 -1.3 -1.8 05/02/2005 07:10:00 8.9 0.5 9.9 7.6 8.9 0.6 10.7 7.2 0.4 0 0.4 0.4 48 0 48 305 88 0 88 0 -1.5 0 -1.3 -1.8 05/02/2005 07:20:00 9.3 0.3 9.9 8.4 9.5 0.4 10.7 8.4 0.4 0 0.4 0.4 48 0 48 305 87 0 87 0 -1.7 0 -1.5 -1.8 05/02/2005 07:30:00 9.1 0.5 10.3 7.6 9.2 0.6 10.7 6.8 0.4 0 0.4 0.4 48 0 48 305 86 0 86 0 -1.7 0 -1.3 -1.8 05/02/2005 07:40:00 8.7 0.6 10.3 7.2 8.8 0.7 10.3 6.8 0.4 0 0.4 0.4 48 0 48 305 86 0 86 0 -1.7 0 -1.5 -2 05/02/2005 07:50:00 7.6 0.4 8.4 6.5 7.8 0.5 8.8 6.1 0.4 0 0.4 0.4 48 0 48 305 85 0 86 0 -1.7 0 -1.5 -2 05/02/2005 08:00:00 8.4 0.5 9.5 7.2 8.5 0.5 9.9 6.5 0.4 0 0.4 0.4 48 0 48 305 85 0 85 0 -1.7 0 -1.8 -2 05/02/2005 08:10:00 8.7 0.5 9.9 7.2 8.7 0.6 9.9 6.8 0.4 0 0.4 0.4 48 0 48 305 85 0 85 0 -1.7 0 -1.5 -1.8 05/02/2005 08:20:00 8.8 0.4 9.5 7.6 8.9 0.4 9.9 7.6 0.4 0 0.4 0.4 48 0 48 305 84 0 84 0 -1.7 0 -1.8 -1.8 05/02/2005 08:30:00 8.9 0.8 10.7 6.8 9 0.9 11.1 6.8 0.4 0 0.4 0.4 48 0 48 305 83 0 83 0 -1.7 0 -1.8 -1.8 05/02/2005 08:40:00 7.6 0.6 8.8 5.7 7.7 0.7 9.1 4.9 0.4 0 0.4 0.4 48 0 48 305 82 0 82 0 -1.7 0 -1.3 -1.8 05/02/2005 08:50:00 8 0.5 9.1 6.5 8.1 0.5 9.5 6.5 0.4 0 0.4 0.4 48 0 48 305 81 0 82 0 -1.7 0 -1.8 -2 05/02/2005 09:00:00 7.8 0.6 9.1 6.5 7.9 0.6 9.5 6.5 0.4 0 0.4 0.4 48 0 48 305 80 0 80 0 -1.7 0 -1.8 -2 05/02/2005 09:10:00 8.7 0.5 9.9 6.8 8.8 0.6 10.3 6.5 0.4 0 0.7 0.4 48 0 48 305 80 0 79 0 -1.7 0 -1.8 -2 05/02/2005 09:20:00 8.6 0.7 9.9 6.5 8.7 0.7 10.3 6.8 0.4 0 0.4 0.4 48 0 48 305 78 0 79 0 -1.9 0 -1.8 -2 05/02/2005 09:30:00 7.9 0.4 8.8 6.5 8 0.4 8.8 6.8 0.4 0 0.4 0.4 48 0 48 305 78 0 78 0 -1.8 0 -1.8 -2 05/02/2005 09:40:00 8.2 0.7 9.5 6.5 8.4 0.7 9.9 6.5 0.4 0 0.4 0.4 48 0 48 305 77 0 77 0 -1.7 0 -1.5 -2 05/02/2005 09:50:00 7.8 0.5 8.8 6.5 7.8 0.6 9.1 5.7 0.4 0 0.4 0.4 48 0 48 305 76 0 77 0 -1.7 0 -1.5 -2 05/02/2005 10:00:00 8.3 0.9 10.3 6.5 8.3 0.9 10.3 6.5 0.4 0 0.4 0.4 48 0 48 305 76 0 76 0 -1.6 0 -1.1 -1.8 05/02/2005 10:10:00 8.3 0.7 9.5 6.1 8.4 0.7 9.5 6.1 0.4 0 0.4 0.4 48 0 48 305 75 0 76 0 -1.6 0 -1.5 -1.8 05/02/2005 10:20:00 7.8 0.5 9.1 6.1 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 48 0 48 305 75 0 75 0 -1.6 0 -1.1 -1.8 05/02/2005 10:30:00 9.1 0.4 9.9 8 9.2 0.5 10.3 7.6 0.4 0 0.4 0.4 48 0 48 305 74 0 74 0 -1.6 0 -1.5 -1.8 05/02/2005 10:40:00 9 0.5 10.3 8 9.1 0.6 10.7 8 0.4 0 0.4 0.4 48 0 48 305 73 0 73 0 -1.6 0 -1.1 -1.8 05/02/2005 10:50:00 9.1 0.5 10.3 7.6 9.2 0.5 10.3 7.6 0.4 0 0.4 0.4 48 0 48 305 72 0 73 0 -1.5 0 -1.1 -1.8 05/02/2005 11:00:00 8.5 0.6 9.9 6.8 8.7 0.6 9.9 6.5 0.4 0 0.4 0.4 48 0 48 305 71 0 71 0 -1.5 0.1 -1.1 -1.8 05/02/2005 11:10:00 8.7 0.6 10.3 7.6 8.7 0.6 10.7 7.2 0.4 0 0.4 0.4 48 0 48 305 70 0 70 0 -1.5 0 -1.1 -1.8 05/02/2005 11:20:00 8.9 0.5 9.9 7.2 9 0.7 10.3 6.8 0.4 0 0.4 0.4 48 0 48 305 69 0 69 0 -1.5 0.1 -1.1 -1.8 05/02/2005 11:30:00 8.7 0.5 9.9 7.6 8.8 0.5 9.9 7.6 0.4 0 0.4 0.4 48 0 48 305 68 0 69 0 -1.4 0 -0.6 -1.5 05/02/2005 11:40:00 8.1 0.4 9.1 7.2 8.2 0.6 9.9 6.5 0.4 0 0.4 0.4 48 0 48 305 66 1 67 0 -1.2 0.1 -0.6 -1.5 05/02/2005 11:50:00 8.4 0.8 10.7 6.8 8.5 0.8 11.1 6.5 0.4 0 0.4 0.4 48 0 48 305 63 1 63 0 -1.2 0 -0.6 -1.3 05/02/2005 12:00:00 8.9 0.6 10.7 7.2 9 0.6 10.7 7.2 0.4 0 0.4 0.4 48 0 48 305 61 1 62 0 -1.1 0.1 -0.6 -1.3 05/02/2005 12:10:00 8 0.5 8.8 6.5 8 0.6 9.1 6.1 0.4 0 0.4 0.4 48 0 48 305 58 1 59 0 -1.1 0 -0.6 -1.3 05/02/2005 12:20:00 8.1 0.4 9.1 7.2 8.2 0.5 9.1 6.5 0.4 0 0.4 0.4 48 0 48 305 55 1 56 0 -1 0.1 -0.4 -1.1 05/02/2005 12:30:00 8.7 0.6 10.3 6.8 8.9 0.7 10.3 6.1 0.4 0 0.4 0.4 48 0 48 305 52 1 53 0 -0.9 0.1 -0.4 -1.1 05/02/2005 12:40:00 8.5 0.4 9.5 7.6 8.6 0.5 9.9 6.8 0.4 0 0.4 0.4 48 0 48 305 49 1 48 0 -0.7 0 -0.1 -1.1 05/02/2005 12:50:00 8.5 0.5 9.5 6.8 8.5 0.6 9.5 6.5 0.4 0 0.4 0.4 48 0 48 305 47 0 47 0 -0.6 0.1 0.1 -1.1 05/02/2005 13:00:00 8.6 0.4 9.5 7.6 8.6 0.5 9.9 7.2 0.4 0 0.4 0.4 48 0 48 305 43 1 45 0 -0.5 0 0.1 -0.6 05/02/2005 13:10:00 8.1 0.4 9.1 7.2 8.1 0.4 9.1 6.8 0.4 0 0.4 0.4 48 0 48 305 38 2 40 0 -0.5 0 -0.4 -0.6 05/02/2005 13:20:00 8.5 0.5 9.9 7.2 8.4 0.6 9.9 6.8 0.4 0 0.4 0.4 48 0 48 305 34 1 35 0 -0.3 0 0.3 -0.6 05/02/2005 13:30:00 8.4 0.4 9.5 7.6 8.2 0.5 9.5 6.8 0.4 0 0.4 0.4 48 0 48 305 31 1 29 0 -0.4 0 0.1 -0.6 05/02/2005 13:40:00 8.5 0.5 9.9 6.8 8.3 0.5 9.9 6.5 0.4 0 0.4 0.4 48 0 48 305 28 0 27 0 -0.3 0.1 0.1 -0.6 05/02/2005 13:50:00 8.4 0.5 9.5 6.8 8.3 0.5 9.5 6.8 0.4 0 0.4 0.4 48 0 48 305 26 0 27 0 0 0 0.3 -0.4 05/02/2005 14:00:00 8.6 0.5 9.9 7.2 8.5 0.5 9.9 7.2 0.4 0 0.4 0.4 48 0 48 305 24 1 25 0 0 0 0.3 -0.1 05/02/2005 14:10:00 8.3 0.4 9.5 7.2 8.3 0.4 9.5 6.5 0.4 0 0.4 0.4 48 0 48 305 23 0 23 0 0 0.1 0.3 -0.4 05/02/2005 14:20:00 7.5 0.5 8.4 6.1 7.4 0.6 8.8 5.7 0.4 0 0.4 0.4 48 0 48 305 21 0 22 0 0 0 0.6 -0.4 05/02/2005 14:30:00 7.3 0.5 8.8 6.1 7.5 0.7 9.1 5.3 0.4 0 0.4 0.4 48 0 48 305 20 0 20 0 0 0 0.3 -0.1 05/02/2005 14:40:00 7.5 0.4 8.4 6.5 7.9 0.5 8.8 6.1 0.4 0 0.4 0.4 48 0 48 305 19 0 19 0 0.1 0.1 0.8 0.1 05/02/2005 14:50:00 7.6 0.5 8.8 6.5 8.3 0.6 9.9 6.5 0.4 0 0.4 0.4 48 0 48 305 18 0 18 0 0.1 0.1 0.8 -0.1 05/02/2005 15:00:00 7.3 0.5 8.8 6.1 8.1 0.6 9.5 6.1 0.4 0 0.4 0.4 48 0 48 305 17 0 17 0 0.1 0.1 0.6 0.1 05/02/2005 15:10:00 6.4 0.4 7.2 5.3 7.3 0.4 8.4 6.1 0.4 0 0.4 0.4 48 0 48 305 16 0 16 0 0.2 0.1 0.8 0.1 05/02/2005 15:20:00 6.5 0.4 8 5.7 7.5 0.5 8.8 6.1 0.4 0 0.4 0.4 48 0 48 305 15 0 15 0 0.3 0.1 0.8 0.1 05/02/2005 15:30:00 7.3 0.4 8 6.5 8.1 0.5 9.1 6.5 0.4 0 0.4 0.4 48 0 48 305 14 0 15 0 0.3 0 1 0.1 05/02/2005 15:40:00 7.1 0.4 8.4 5.7 7.9 0.6 9.1 6.5 0.4 0 0.4 0.4 48 0 48 305 13 0 14 0 0.4 0.1 1 0.1 05/02/2005 15:50:00 7.2 0.4 8 5.7 7.9 0.5 8.8 6.1 0.4 0 0.4 0.4 48 0 48 305 13 0 13 0 0.4 0.1 1 0.1 05/02/2005 16:00:00 6.9 0.3 8 6.1 7.7 0.4 8.4 6.8 0.4 0 0.4 0.4 48 0 48 305 12 0 12 0 0.3 0.1 1 0.1 05/02/2005 16:10:00 7.2 0.3 8.4 6.5 7.6 0.4 8.8 6.1 0.4 0 0.4 0.4 48 0 48 305 12 0 11 0 0.3 0.1 0.8 0.1 05/02/2005 16:20:00 6.8 0.4 7.6 5.7 6.9 0.5 8 5.7 0.4 0 0.4 0.4 48 0 48 305 11 0 11 0 0.4 0 1 0.1 05/02/2005 16:30:00 7 0.5 8 5.7 6.9 0.5 8 5.3 0.4 0 0.4 0.4 48 0 48 305 11 0 11 0 0.4 0.1 1 0.1 05/02/2005 16:40:00 6.7 0.4 7.6 5.7 6.6 0.4 7.6 5.3 0.4 0 0.4 0.4 48 0 48 305 10 0 10 0 0.6 0.1 1.3 0.1 05/02/2005 16:50:00 6.4 0.4 7.6 5.7 6.3 0.5 7.2 4.9 0.4 0 0.4 0.4 48 0 48 305 9 0 10 0 0.6 0.1 1 0.3 05/02/2005 17:00:00 6.6 0.3 7.6 5.7 6.5 0.4 7.2 5.7 0.4 0 0.4 0.4 48 0 48 305 9 0 9 0 0.5 0 1 0.3 05/02/2005 17:10:00 6.8 0.3 7.6 5.7 6.8 0.4 7.6 5.3 0.4 0 0.4 0.4 48 0 48 305 8 0 8 0 0.4 0.1 1 0.1 05/02/2005 17:20:00 6.6 0.4 7.6 5.7 6.5 0.4 7.6 5.3 0.4 0 0.4 0.4 48 0 48 305 8 0 8 0 0.4 0 0.8 0.3 05/02/2005 17:30:00 6.6 0.4 7.6 5.7 6.6 0.5 7.6 5.3 0.4 0 0.4 0.4 48 0 48 305 8 0 8 0 0.2 0.1 0.8 0.1 05/02/2005 17:40:00 6.2 0.4 6.8 5.3 6.1 0.5 7.2 4.6 0.4 0 0.4 0.4 48 0 48 305 8 0 8 0 0.4 0 1 0.3 05/02/2005 17:50:00 6.3 0.5 7.6 5.3 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 48 0 48 305 7 0 7 0 0.4 0 1 0.3 05/02/2005 18:00:00 6.7 0.4 7.6 5.7 6.6 0.4 7.6 5.3 0.4 0 0.4 0.4 48 0 48 305 7 0 7 0 0.4 0.1 1 0.1 05/02/2005 18:10:00 6.7 0.3 7.2 5.7 6.6 0.4 7.6 5.3 0.4 0 0.4 0.4 48 0 48 305 6 0 6 0 0.5 0.1 1 0.1 05/02/2005 18:20:00 6.3 0.3 7.2 5.3 6.2 0.4 7.2 4.9 0.4 0 0.4 0.4 48 0 48 305 6 0 6 0 0.4 0.1 1 0.1 05/02/2005 18:30:00 6.3 0.3 6.8 5.3 6.3 0.3 7.2 4.6 0.4 0 0.4 0.4 48 0 48 305 6 0 6 0 0.4 0.2 1 0.1 05/02/2005 18:40:00 6.5 0.4 7.6 4.9 6.4 0.5 7.2 4.6 0.4 0 0.4 0.4 48 0 48 305 6 0 6 0 0.3 0.1 0.8 0.1 05/02/2005 18:50:00 6.3 0.3 6.8 5.7 6.3 0.3 6.8 5.3 0.4 0 0.4 0.4 48 0 48 305 6 0 6 0 0.2 0.1 0.6 0.1 05/02/2005 19:00:00 6.7 0.4 7.6 5.3 6.5 0.4 7.6 5.3 0.4 0 0.4 0.4 48 0 48 305 6 0 6 0 0.3 0.1 0.8 0.1 05/02/2005 19:10:00 7 0.5 8.4 5.7 6.9 0.5 8 4.9 0.4 0 0.4 0.4 48 0 48 305 6 0 6 0 0.2 0.1 0.8 0.1 05/02/2005 19:20:00 7.4 0.4 8.4 6.5 7.2 0.5 8.4 5.7 0.4 0 0.4 0.4 48 0 48 305 6 0 6 0 0.2 0.1 0.6 0.1 05/02/2005 19:30:00 7.3 0.4 8.8 6.1 7.1 0.4 8.4 6.1 0.4 0 0.4 0.4 48 0 48 305 6 0 5 0 0.1 0.1 0.6 -0.1 05/02/2005 19:40:00 7 0.4 8.4 6.1 6.9 0.5 8.4 5.7 0.4 0 0.4 0.4 48 0 48 305 6 0 6 0 0 0.2 0.6 -0.4 05/02/2005 19:50:00 7.1 0.4 9.1 6.1 7 0.5 8.8 5.7 0.4 0 0.4 0.4 48 0 48 305 7 0 7 0 0 0 0.6 -0.4 05/02/2005 20:00:00 6.8 0.4 7.6 5.7 6.7 0.5 7.6 5.7 0.4 0 0.4 0.4 47 0 48 305 7 0 7 0 0 0.1 0.6 -0.1 05/02/2005 20:10:00 6.1 0.3 7.2 5.3 6.1 0.3 7.2 5.3 0.4 0 0.4 0.4 47 0 48 305 7 0 7 0 -0.1 0 0.3 -0.4 05/02/2005 20:20:00 5.7 0.3 6.5 4.9 5.7 0.3 6.5 4.9 0.4 0 0.4 0.4 47 0 48 305 7 0 7 0 0 0 0.3 -0.4 05/02/2005 20:30:00 5.7 0.3 6.8 4.9 5.7 0.4 7.2 4.6 0.4 0 0.4 0.4 48 0 48 305 7 0 7 0 -0.3 0 0.3 -0.4 05/02/2005 20:40:00 5.8 0.3 6.8 4.9 5.7 0.4 6.8 4.6 0.4 0 0.4 0.4 47 0 48 305 7 0 7 0 -0.3 0 0.3 -0.4 05/02/2005 20:50:00 5.6 0.3 6.8 4.9 5.6 0.4 6.8 4.6 0.4 0 0.4 0.4 47 0 48 305 8 0 8 0 -0.3 0.1 0.3 -0.4 05/02/2005 21:00:00 6.2 0.3 6.8 5.3 6.2 0.4 6.8 5.3 0.4 0 0.4 0.4 47 0 48 305 8 0 8 0 -0.4 0.1 0.1 -0.6 05/02/2005 21:10:00 6.7 0.3 7.6 6.1 6.7 0.4 7.6 5.7 0.4 0 0.4 0.4 47 0 48 305 9 0 9 0 -0.5 0.1 0.1 -0.6 05/02/2005 21:20:00 7.1 0.3 8 6.5 7 0.4 8 6.1 0.4 0 0.4 0.4 47 0 48 305 10 0 10 0 -0.7 0 -0.4 -0.8 05/02/2005 21:30:00 7 0.3 8 6.1 6.9 0.4 8 6.1 0.4 0 0.4 0.4 48 0 48 305 12 1 13 0 -0.8 0 -0.4 -1.1 05/02/2005 21:40:00 6.7 0.4 7.6 5.7 6.6 0.4 7.6 5.3 0.4 0 0.7 0.4 48 0 48 305 15 1 14 0 -0.8 0.1 -0.4 -1.1 05/02/2005 21:50:00 6.9 0.4 7.6 6.1 6.9 0.4 8 5.7 0.4 0 0.4 0.4 48 0 48 305 17 1 17 0 -0.8 0.1 -0.4 -1.1 05/02/2005 22:00:00 7.2 0.4 8.4 6.1 7.1 0.5 8.4 5.7 0.4 0 0.4 0.4 48 0 48 305 19 1 19 0 -0.8 0.1 -0.4 -1.1 05/02/2005 22:10:00 7.1 0.4 8.4 6.1 7.1 0.4 8 6.1 0.4 0 0.4 0.4 48 0 48 305 21 0 21 0 -0.7 0.1 -0.4 -1.1 05/02/2005 22:20:00 7.4 0.5 8.8 6.1 7.3 0.5 8.8 5.7 0.4 0 0.4 0.4 48 0 48 305 23 0 24 0 -0.7 0 -0.4 -0.8 05/02/2005 22:30:00 8.2 0.9 10.7 6.5 7.9 0.9 11.1 6.1 0.4 0 0.4 0.4 47 0 47 305 25 0 26 0 -0.5 0.1 0.1 -0.6 05/02/2005 22:40:00 10 0.6 12.2 8.8 9.8 0.6 11.5 8.4 0.4 0 0.4 0.4 30 9 18 305 27 0 27 0 -0.1 0 0.3 -0.4 05/02/2005 22:50:00 10.5 0.7 12.6 9.1 10.3 0.8 13.3 8.4 0.4 0 0.4 0.4 24 4 24 305 28 0 28 0 0 0 0.3 -0.1 05/02/2005 23:00:00 11.3 0.7 13.3 9.5 11.3 0.8 13 9.1 0.4 0 0.4 0.4 20 3 18 305 29 0 29 0 0 0 0.3 -0.1 05/02/2005 23:10:00 11.8 0.7 13.3 9.9 11.6 0.8 13.7 9.5 0.4 0 0.4 0.4 15 4 24 305 31 0 31 0 0 0 0.3 -0.1 05/02/2005 23:20:00 11.8 0.8 13.7 9.5 11.6 0.8 13.7 8.8 0.4 0 0.4 0.4 14 4 11 305 32 0 32 0 0 0 0.3 -0.1 05/02/2005 23:30:00 12.1 0.7 14.1 10.3 11.9 0.8 14.5 9.9 0.4 0 0.4 0.4 13 3 9 305 34 0 34 0 0 0 0.3 -0.1 05/02/2005 23:40:00 12 1 14.9 9.1 11.9 1 14.5 9.1 0.4 0 0.4 0.4 11 4 12 305 35 0 35 0 0 0 0.3 -0.1 05/02/2005 23:50:00 12.5 0.8 14.9 10.3 12.4 0.9 14.9 9.5 0.4 0 0.4 0.4 12 3 9 305 36 0 35 0 0 0 0.6 -0.1 05/03/2005 00:00:00 12.6 0.9 14.5 10.3 12.4 1 14.5 9.5 0.4 0 0.4 0.4 14 4 7 305 37 0 37 0 -0.1 0 0.3 -0.4 05/03/2005 00:10:00 12.6 1 15.6 10.7 12.4 1 15.3 9.5 0.4 0 0.4 0.4 13 4 8 305 38 0 38 0 -0.2 0 0.3 -0.4 05/03/2005 00:20:00 12.5 0.9 14.9 9.9 12.4 1 14.9 10.3 0.4 0 0.4 0.4 12 4 8 305 38 0 38 0 -0.3 0 0.3 -0.4 05/03/2005 00:30:00 13.3 1 16.1 10.3 13 1.1 15.6 10.7 0.4 0 0.4 0.4 10 5 13 305 38 0 38 0 -0.4 0 0.1 -0.4 05/03/2005 00:40:00 13.6 1 16.4 10.3 13.6 1.1 16.4 10.7 0.4 0 0.4 0.4 7 4 4 305 38 0 38 0 -0.4 0.1 0.1 -0.6 05/03/2005 00:50:00 13.8 1 16.4 10.7 13.8 1.1 16.4 10.3 0.4 0 0.4 0.4 6 3 7 305 38 0 38 0 -0.4 0.1 0.1 -0.6 05/03/2005 01:00:00 13.2 1.1 16.4 10.3 13.1 1.2 16.4 9.9 0.4 0 0.4 0.4 7 4 10 305 37 0 37 0 -0.4 0 0.1 -0.6 05/03/2005 01:10:00 13.9 1.1 16.8 10.7 13.8 1.2 17.2 10.7 0.4 0 0.4 0.4 6 4 6 305 37 0 37 0 -0.4 0.1 0.1 -0.6 05/03/2005 01:20:00 14.1 1.3 17.6 11.1 14.1 1.4 17.6 10.3 0.4 0 0.4 0.4 4 4 2 305 36 0 36 0 -0.5 0 0.1 -0.6 05/03/2005 01:30:00 14.9 1.3 18.3 11.8 15 1.3 18.7 11.8 0.4 0 0.4 0.4 5 4 1 305 36 0 36 0 -0.5 0 0.1 -0.6 05/03/2005 01:40:00 14.8 1.3 18.3 11.8 14.7 1.3 18.3 10.7 0.4 0 0.4 0.4 6 4 0 305 36 0 36 0 -0.5 0 0.1 -0.6 05/03/2005 01:50:00 14.9 1.1 18.3 11.8 14.9 1.2 18.3 11.8 0.4 0 0.4 0.4 6 4 1 305 36 0 36 0 -0.6 0 0.1 -0.6 05/03/2005 02:00:00 14.3 1.2 17.2 11.5 14.2 1.2 17.2 10.7 0.4 0 0.4 0.4 5 4 11 305 37 0 36 0 -0.6 0 0.1 -0.6 05/03/2005 02:10:00 13.7 1 16.4 10.7 13.7 1.1 16.8 11.1 0.4 0 0.4 0.4 7 4 9 305 37 0 37 0 -0.6 0 0.1 -0.6 05/03/2005 02:20:00 14.2 1.3 17.9 11.5 14.3 1.3 17.9 10.3 0.4 0 0.4 0.4 8 4 9 305 37 0 37 0 -0.6 0 -0.1 -0.8 05/03/2005 02:30:00 15 1.2 17.9 12.2 15.1 1.3 18.3 11.5 0.4 0 0.4 0.4 6 4 5 305 37 0 37 0 -0.7 0 -0.1 -0.8 05/03/2005 02:40:00 15.5 1.5 19.5 11.8 15.6 1.4 20.2 12.2 0.4 0 0.4 0.4 6 4 2 305 37 0 37 0 -0.8 0 -0.4 -0.8 05/03/2005 02:50:00 15.5 1.4 19.1 11.8 15.6 1.5 19.9 11.5 0.4 0 0.4 0.4 6 4 8 305 37 0 37 0 -0.8 0 -0.4 -1.1 05/03/2005 03:00:00 15.6 1.3 19.1 12.6 15.5 1.5 19.1 11.8 0.4 0 0.4 0.4 4 4 7 305 36 0 36 0 -0.9 0 -0.4 -1.1 05/03/2005 03:10:00 16.1 1.4 19.1 11.8 16.2 1.5 19.1 11.8 0.4 0 0.4 0.4 3 3 4 305 36 0 36 0 -1 0.1 -0.4 -1.1 05/03/2005 03:20:00 14.6 1.2 17.9 11.1 14.6 1.3 17.9 10.7 0.4 0 0.4 0.4 5 4 7 305 36 0 36 0 -1.1 0.1 -0.6 -1.3 05/03/2005 03:30:00 15.9 1.1 19.5 12.6 15.9 1.2 19.5 12.2 0.4 0 0.4 0.4 4 4 6 305 36 0 36 0 -1.1 0 -0.6 -1.3 05/03/2005 03:40:00 14.6 1.1 16.8 11.1 14.5 1.3 17.2 10.3 0.4 0 0.4 0.4 6 4 3 305 36 0 36 0 -1.1 0 -0.6 -1.3 05/03/2005 03:50:00 15.2 1.3 18.3 12.2 15.2 1.3 18.3 11.1 0.4 0 0.4 0.4 5 4 4 305 36 0 36 0 -1.1 0 -0.6 -1.3 05/03/2005 04:00:00 14.8 1.2 17.6 11.1 15 1.2 18.3 12.2 0.4 0 0.4 0.4 7 3 2 305 36 0 36 0 -1.1 0 -0.6 -1.1 05/03/2005 04:10:00 14.4 1.3 17.6 11.5 14.5 1.2 17.2 11.5 0.4 0 0.4 0.4 8 4 5 305 35 0 35 0 -1.1 0 -0.6 -1.1 05/03/2005 04:20:00 14.6 1.3 18.7 11.5 14.6 1.5 18.7 11.1 0.4 0 0.4 0.4 5 4 4 305 35 0 35 0 -1.1 0 -0.6 -1.1 05/03/2005 04:30:00 15.7 1.3 18.7 11.8 15.8 1.3 19.1 11.8 0.4 0 0.4 0.4 5 4 5 305 36 0 36 0 -1.1 0.1 -0.6 -1.1 05/03/2005 04:40:00 14 1.1 17.2 10.7 14.1 1.2 16.4 11.1 0.4 0 0.4 0.4 7 4 3 305 37 0 36 0 -1 0.1 -0.4 -1.1 05/03/2005 04:50:00 13.8 1.1 16.4 11.1 13.8 1.3 16.8 10.3 0.4 0 0.4 0.4 6 4 10 305 37 0 38 0 -0.9 0 -0.4 -1.1 05/03/2005 05:00:00 13.6 1.4 16.8 10.3 13.6 1.5 17.2 10.3 0.4 0 0.4 0.4 8 4 8 305 37 0 38 0 -0.8 0.1 -0.4 -1.1 05/03/2005 05:10:00 15.2 1.1 17.9 12.2 15.1 1.2 17.9 11.1 0.4 0 0.4 0.4 6 3 2 305 37 0 37 0 -0.8 0.1 -0.4 -1.1 05/03/2005 05:20:00 14 1.3 17.6 10.7 14.2 1.3 17.2 11.1 0.4 0 0.4 0.4 6 3 6 305 37 0 36 0 -0.9 0.2 -0.4 -1.1 05/03/2005 05:30:00 14.9 1.6 18.7 11.5 14.9 1.6 18.3 11.1 0.4 0 0.4 0.4 5 4 9 305 36 0 36 0 -1 0.2 -0.4 -1.1 05/03/2005 05:40:00 14.3 1.6 17.9 11.1 14.2 1.7 18.3 10.3 0.4 0 0.4 0.4 5 4 359 305 36 0 36 0 -1 0.1 -0.4 -1.1 05/03/2005 05:50:00 14.5 1.2 17.6 11.5 14.6 1.2 17.6 11.5 0.4 0 0.4 0.4 4 4 6 305 35 0 35 0 -1.1 0.1 -0.6 -1.3 05/03/2005 06:00:00 14.3 1.2 17.2 10.7 14.3 1.2 17.2 10.3 0.4 0 0.4 0.4 5 4 4 305 35 0 35 0 -1.1 0.1 -0.6 -1.3 05/03/2005 06:10:00 13.5 1.3 17.6 11.1 13.6 1.5 17.9 10.7 0.4 0 0.4 0.4 9 4 7 305 35 0 34 0 -1.2 0 -0.6 -1.3 05/03/2005 06:20:00 15.4 1.3 18.7 12.2 15.4 1.4 19.1 11.8 0.4 0 0.4 0.4 1 4 358 305 34 0 34 0 -1.2 0 -0.6 -1.3 05/03/2005 06:30:00 13.4 1.3 17.6 9.9 13.4 1.4 17.9 10.3 0.4 0 0.4 0.4 7 4 6 305 33 0 32 0 -1.3 0.1 -0.6 -1.3 05/03/2005 06:40:00 14.8 1.1 17.9 11.8 15 1.2 18.3 11.8 0.4 0 0.4 0.4 2 4 358 305 32 0 32 0 -1.4 0 -0.8 -1.5 05/03/2005 06:50:00 15.1 1 17.9 12.6 15.1 1.1 17.9 12.6 0.4 0 0.4 0.4 1 4 350 305 32 0 32 0 -1.3 0 -0.6 -1.5 05/03/2005 07:00:00 14.2 1.5 17.2 10.3 14.2 1.7 17.2 9.9 0.4 0 0.4 0.4 359 5 358 305 31 0 31 0 -1.4 0.1 -0.8 -1.8 05/03/2005 07:10:00 15.6 1.1 17.9 12.2 15.7 1.3 18.3 11.8 0.4 0 0.4 0.4 358 3 359 305 31 0 31 0 -1.5 0.1 -1.1 -1.8 05/03/2005 07:20:00 16.1 1.2 18.7 12.2 16.2 1.2 19.5 12.6 0.4 0 0.4 0.4 357 5 356 305 30 0 29 0 -1.7 0 -1.1 -2 05/03/2005 07:30:00 15.2 1.5 17.9 11.5 15.3 1.6 18.3 11.1 0.4 0 0.4 0.4 0 4 0 305 29 0 29 0 -1.8 0 -1.3 -2 05/03/2005 07:40:00 15.6 1.3 18.3 11.8 15.5 1.3 18.7 12.6 0.4 0 0.4 0.4 0 4 1 305 28 0 28 0 -1.9 0 -1.3 -2 05/03/2005 07:50:00 15.4 1.5 19.1 12.2 15.3 1.7 18.7 11.5 0.4 0 0.4 0.4 2 4 1 305 28 0 28 0 -2 0.1 -1.3 -2 05/03/2005 08:00:00 15.7 1.5 19.5 12.2 15.8 1.5 19.9 11.5 0.4 0 0.4 0.4 1 4 1 305 27 0 27 0 -2.1 0 -1.8 -2.2 05/03/2005 08:10:00 15.6 1.3 19.1 11.8 15.5 1.5 20.2 10.7 0.4 0 0.4 0.4 2 4 2 305 27 0 27 0 -2.2 0 -2 -2.2 05/03/2005 08:20:00 16.6 1.7 19.9 11.5 16.6 1.7 20.6 11.5 0.4 0 0.4 0.4 0 4 4 305 27 0 26 0 -2.2 0 -1.8 -2.2 05/03/2005 08:30:00 17.9 1.4 20.6 13.3 18 1.5 21 13.3 0.4 0 0.4 0.4 358 4 356 305 26 0 26 0 -2.3 0 -1.8 -2.4 05/03/2005 08:40:00 16.6 1.6 19.5 12.6 16.6 1.7 19.9 11.8 0.4 0 0.4 0.4 1 4 356 305 26 0 26 0 -2.3 0 -2.2 -2.4 05/03/2005 08:50:00 15.6 1.5 19.5 11.8 15.7 1.6 19.5 11.5 0.4 0 0.4 0.4 1 4 358 305 25 0 25 0 -2.3 0 -2.2 -2.4 05/03/2005 09:00:00 13.9 1.1 17.2 11.1 14.1 1.2 17.6 11.5 0.4 0 0.4 0.4 3 5 2 305 25 0 25 0 -2.2 0 -2 -2.4 05/03/2005 09:10:00 15.2 1.3 18.7 11.5 15.2 1.2 18.3 11.5 0.4 0 0.4 0.4 4 5 359 305 25 0 25 0 -2.4 0 -2.2 -2.7 05/03/2005 09:20:00 16.2 1.4 19.1 11.8 16.3 1.4 19.5 12.2 0.4 0 0.4 0.4 0 5 358 305 25 0 25 0 -2.5 0 -2.2 -2.7 05/03/2005 09:30:00 17 1.6 20.2 11.8 17.1 1.7 20.2 11.8 0.4 0 0.4 0.4 2 4 359 305 24 0 24 0 -2.6 0 -2.4 -2.7 05/03/2005 09:40:00 16.6 1.5 19.9 13.3 16.6 1.5 20.2 12.6 0.4 0 0.4 0.4 1 4 0 305 24 0 24 0 -2.6 0 -2.4 -2.7 05/03/2005 09:50:00 15.1 1.3 17.9 11.1 15.2 1.5 18.7 11.1 0.4 0 0.4 0.4 2 5 0 305 24 0 24 0 -2.6 0 -2.4 -2.7 05/03/2005 10:00:00 16.8 1.3 19.5 12.6 16.7 1.5 19.9 12.2 0.4 0 0.4 0.4 2 4 4 305 24 0 24 0 -2.7 0 -2.4 -2.7 05/03/2005 10:10:00 15.4 1.7 19.5 11.5 15.5 1.7 19.9 11.1 0.4 0 0.4 0.4 3 5 3 305 23 0 23 0 -2.6 0 -2.4 -2.7 05/03/2005 10:20:00 18.1 1.7 21.4 13.7 18 1.7 22.1 13.7 0.4 0 0.4 0.4 1 5 354 305 23 0 22 0 -2.6 0 -2.4 -2.7 05/03/2005 10:30:00 19.7 1.5 22.9 15.6 19.6 1.6 22.9 14.5 0.4 0 0.4 0.4 359 4 355 305 21 0 21 0 -2.8 0 -2.2 -3.1 05/03/2005 10:40:00 17.9 1.8 21.8 13.3 18 1.8 22.1 14.1 0.4 0 0.4 0.4 358 4 0 305 21 0 21 0 -2.9 0 -2.7 -3.1 05/03/2005 10:50:00 18.1 1.5 21 13.7 18.1 1.5 21 13 0.4 0 0.4 0.4 358 4 356 305 20 0 20 0 -3.2 0 -2.9 -3.3 05/03/2005 11:00:00 16.7 1.6 19.9 11.5 16.8 1.6 20.2 12.6 0.4 0 0.4 0.4 0 4 3 305 19 0 19 0 -3.1 0 -2.9 -3.3 05/03/2005 11:10:00 17.2 1.3 20.2 13 17.2 1.4 20.2 13.7 0.4 0 0.4 0.4 358 5 357 305 19 0 19 0 -3.2 0 -2.7 -3.3 05/03/2005 11:20:00 16.5 1.3 19.9 13.7 16.5 1.4 19.9 12.6 0.4 0 0.4 0.4 3 5 7 305 19 0 19 0 -3.1 0 -2.7 -3.3 05/03/2005 11:30:00 17.2 1.5 20.2 13 17.1 1.5 20.6 13 0.4 0 0.4 0.4 2 4 8 305 19 0 19 0 -3 0 -2.7 -3.1 05/03/2005 11:40:00 17.4 1.4 20.2 12.6 17.3 1.5 20.2 13 0.4 0 0.4 0.4 1 4 355 305 18 0 19 0 -2.8 0 -2.7 -3.1 05/03/2005 11:50:00 17.3 1.8 20.6 13 17.3 2 21 12.6 0.4 0 0.4 0.4 2 4 358 305 17 0 18 0 -3 0 -2.7 -3.1 05/03/2005 12:00:00 18.5 1.4 21.4 13.7 18.4 1.5 21.4 13.7 0.4 0 0.4 0.4 0 4 359 305 17 0 18 0 -2.9 0 -2.7 -3.1 05/03/2005 12:10:00 18.7 1.6 23.3 14.9 18.6 1.7 23.7 14.9 0.4 0 0.4 0.4 0 5 1 305 16 0 17 0 -2.9 0 -2.7 -3.1 05/03/2005 12:20:00 18.7 1.7 22.9 14.5 18.5 1.8 22.6 13.7 0.4 0 0.4 0.4 3 5 1 305 16 0 16 0 -2.8 0 -2.7 -3.1 05/03/2005 12:30:00 18.8 1.5 22.6 14.9 18.7 1.6 22.6 13.7 0.4 0 0.4 0.4 359 5 358 305 15 1 15 0 -3 0 -2.7 -3.1 05/03/2005 12:40:00 17.4 2 21.4 12.2 17.3 2 21.8 11.1 0.4 0 0.4 0.4 359 5 354 305 14 0 14 0 -2.9 0 -2.7 -3.1 05/03/2005 12:50:00 17.4 1.5 20.2 12.6 17.3 1.5 20.2 13.7 0.4 0 0.4 0.4 357 4 3 305 15 0 14 0 -2.8 0 -2.7 -3.1 05/03/2005 13:00:00 17.3 1.5 21.4 13.3 17.2 1.5 21 12.6 0.4 0 0.4 0.4 356 5 353 305 14 0 14 0 -2.8 0 -2.7 -3.1 05/03/2005 13:10:00 17 1.2 19.9 14.1 16.9 1.3 19.9 13.3 0.4 0 0.4 0.4 359 5 2 305 14 0 14 0 -2.8 0 -2.7 -3.1 05/03/2005 13:20:00 17.2 1.5 20.6 12.6 17.2 1.5 20.6 12.6 0.4 0 0.4 0.4 0 4 0 305 14 0 14 0 -2.8 0 -2.4 -3.1 05/03/2005 13:30:00 16.8 1.3 19.5 13 16.8 1.4 19.9 12.6 0.4 0 0.4 0.4 357 5 4 305 14 0 14 0 -2.7 0 -2.4 -2.7 05/03/2005 13:40:00 17.3 1.7 20.6 12.2 17.3 1.7 21 12.2 0.4 0 0.4 0.4 358 4 357 305 14 0 14 0 -2.6 0 -2.4 -2.7 05/03/2005 13:50:00 17.3 1.6 21 13 17.3 1.6 20.6 13.3 0.4 0 0.4 0.4 0 5 0 305 13 0 13 0 -2.5 0 -2.2 -2.7 05/03/2005 14:00:00 16.4 1.7 19.5 11.5 16.4 1.8 20.2 11.5 0.4 0 0.4 0.4 1 5 355 305 13 0 13 0 -2.3 0 -2 -2.7 05/03/2005 14:10:00 16.8 1.4 20.6 12.2 16.8 1.3 19.5 13 0.4 0 0.4 0.4 359 4 355 305 12 0 12 0 -2.6 0.1 -2.2 -2.7 05/03/2005 14:20:00 16.7 1.5 19.9 13 16.6 1.6 20.2 12.2 0.4 0 0.4 0.4 2 5 353 305 11 0 12 0 -2.4 0 -2.2 -2.7 05/03/2005 14:30:00 16.5 1.5 19.5 12.6 16.6 1.5 19.5 12.6 0.4 0 0.4 0.4 2 3 4 305 11 0 11 0 -2.4 0 -2.4 -2.7 05/03/2005 14:40:00 16.8 1.5 20.2 13 16.8 1.6 20.2 11.8 0.4 0 0.4 0.4 3 4 4 305 11 0 11 0 -2.3 0 -2.2 -2.7 05/03/2005 14:50:00 17.1 1.5 20.6 12.6 17.2 1.6 21.4 13 0.4 0 0.4 0.4 2 5 1 305 11 0 11 0 -2.4 0 -2.2 -2.7 05/03/2005 15:00:00 17.4 1.6 20.6 13 17.5 1.7 21 11.8 0.4 0 0.4 0.4 358 5 359 305 10 0 10 0 -2.5 0.1 -2.2 -2.7 05/03/2005 15:10:00 16 1.7 19.9 12.2 16.2 1.8 20.2 11.8 0.4 0 0.4 0.4 358 4 358 305 10 0 10 0 -2.3 0.1 -2 -2.7 05/03/2005 15:20:00 17.3 1.9 20.6 12.2 17.3 2 20.6 11.5 0.4 0 0.4 0.4 357 4 357 305 10 0 10 0 -2.3 0 -1.8 -2.4 05/03/2005 15:30:00 16.9 1.3 19.9 13.7 16.9 1.3 19.9 13 0.4 0 0.4 0.4 356 4 358 305 10 0 9 0 -2.4 0 -1.8 -2.7 05/03/2005 15:40:00 17.7 1.4 20.2 13.3 17.7 1.5 20.2 13.3 0.4 0 0.4 0.4 355 4 354 305 9 0 9 0 -2.4 0 -1.8 -2.7 05/03/2005 15:50:00 15.9 1.5 19.1 11.8 16 1.4 19.5 12.6 0.4 0 0.4 0.4 359 4 1 305 9 0 9 0 -2.4 0 -2 -2.7 05/03/2005 16:00:00 16.6 1.7 20.2 11.8 16.6 1.6 21 12.2 0.4 0 0.4 0.4 356 4 355 305 10 0 9 0 -2.3 0 -2 -2.4 05/03/2005 16:10:00 17.2 1.6 20.6 13.3 17.2 1.7 20.6 13 0.4 0 0.4 0.4 353 4 355 305 9 0 9 0 -2.4 0 -2 -2.7 05/03/2005 16:20:00 16.8 1.5 20.2 12.6 16.9 1.6 20.6 12.6 0.4 0 0.4 0.4 357 4 358 305 9 0 9 0 -2.3 0 -2 -2.4 05/03/2005 16:30:00 17 1.4 20.2 13 16.9 1.3 20.2 13 0.4 0 0.4 0.4 353 4 352 305 9 0 9 0 -2.3 0.1 -2 -2.7 05/03/2005 16:40:00 16.6 1.4 19.5 11.8 16.7 1.5 19.9 11.8 0.4 0 0.4 0.4 354 4 357 305 9 0 8 0 -2.2 0 -1.8 -2.4 05/03/2005 16:50:00 17.4 1.4 20.2 13.7 17.4 1.4 20.6 13.3 0.4 0 0.4 0.4 356 3 356 305 8 0 8 0 -2.4 0 -2.2 -2.7 05/03/2005 17:00:00 15.9 1.7 19.9 11.8 16 1.7 19.9 11.5 0.4 0 0.4 0.4 358 5 353 305 8 0 9 0 -2.3 0 -2 -2.4 05/03/2005 17:10:00 15.7 1.5 19.5 12.2 15.8 1.7 20.2 11.5 0.4 0 0.4 0.4 358 4 348 305 8 0 8 0 -2.3 0 -1.8 -2.4 05/03/2005 17:20:00 17 1.4 20.6 13.3 17.1 1.5 20.2 13 0.4 0 0.4 0.4 355 5 353 305 8 0 8 0 -2.5 0.1 -2.2 -2.7 05/03/2005 17:30:00 17 1.3 20.2 13 17.1 1.3 20.2 13 0.4 0 0.4 0.4 357 5 356 305 8 0 8 0 -2.4 0 -2 -2.7 05/03/2005 17:40:00 15.8 1 18.3 12.6 15.9 1.1 18.3 12.6 0.4 0 0.4 0.4 355 5 354 305 8 0 8 0 -2.3 0 -2 -2.4 05/03/2005 17:50:00 15.5 1.4 19.1 11.8 15.6 1.4 19.1 12.2 0.4 0 0.4 0.4 359 5 353 305 8 0 8 0 -2.3 0 -1.8 -2.4 05/03/2005 18:00:00 15.4 1.6 18.3 11.1 15.5 1.6 18.7 11.1 0.4 0 0.4 0.4 359 5 359 305 8 0 8 0 -2.2 0 -1.8 -2.4 05/03/2005 18:10:00 15.9 1.7 19.1 10.7 16 1.7 19.1 11.5 0.4 0 0.4 0.4 357 4 358 305 8 0 8 0 -2.4 0.1 -2 -2.7 05/03/2005 18:20:00 15.7 1.5 18.3 10.7 15.8 1.5 19.1 11.5 0.4 0 0.4 0.4 356 4 355 305 8 0 8 0 -2.4 0.2 -2 -2.7 05/03/2005 18:30:00 15.9 1.5 19.5 12.6 15.9 1.7 19.5 11.5 0.4 0 0.4 0.4 354 4 355 305 9 0 9 0 -2.3 0 -2 -2.7 05/03/2005 18:40:00 15.4 1.3 18.7 11.5 15.5 1.5 18.7 11.8 0.4 0 0.4 0.4 358 5 1 305 8 0 8 0 -2.4 0 -2 -2.4 05/03/2005 18:50:00 16.1 1.3 19.1 11.8 16.1 1.5 19.1 11.8 0.4 0 0.4 0.4 357 4 357 305 9 0 8 0 -2.4 0 -2.2 -2.7 05/03/2005 19:00:00 16.1 1.1 18.3 12.6 16.1 1.2 19.1 12.6 0.4 0 0.4 0.4 354 4 352 305 8 0 8 0 -2.6 0.1 -2.2 -2.7 05/03/2005 19:10:00 15.9 1.2 18.3 12.2 16.1 1.4 18.7 11.8 0.4 0 0.4 0.4 356 5 357 305 9 0 8 0 -2.4 0.1 -2 -2.7 05/03/2005 19:20:00 15.7 1.2 18.3 12.2 15.9 1.3 18.7 12.2 0.4 0 0.4 0.4 354 3 354 305 8 0 8 0 -2.3 0 -2 -2.7 05/03/2005 19:30:00 15.1 1.3 17.6 11.1 15.3 1.4 17.9 11.1 0.4 0 0.4 0.4 356 5 0 305 8 0 8 0 -2.7 0 -2.2 -2.7 05/03/2005 19:40:00 15 1.3 17.9 11.1 15.1 1.4 18.3 10.7 0.4 0 0.4 0.4 359 5 353 305 9 0 8 0 -2.7 0 -2.4 -2.9 05/03/2005 19:50:00 16.1 1.3 19.1 12.2 16.2 1.5 19.5 12.6 0.4 0 0.4 0.4 359 4 356 305 9 0 9 0 -2.9 0 -2.4 -3.1 05/03/2005 20:00:00 16.6 1.3 19.5 13.3 16.6 1.4 20.2 12.2 0.4 0 0.4 0.4 0 4 358 305 10 0 10 0 -3.1 0.1 -2.9 -3.3 05/03/2005 20:10:00 16.2 1.1 19.1 13.3 16.2 1.2 18.7 12.6 0.4 0 0.4 0.4 0 4 359 305 10 0 10 0 -3.2 0 -3.1 -3.3 05/03/2005 20:20:00 16.4 1.2 19.1 13 16.4 1.2 19.1 13 0.4 0 0.4 0.4 357 4 2 305 11 0 11 0 -3.3 0 -2.7 -3.3 05/03/2005 20:30:00 15.6 1.2 17.9 11.8 15.6 1.3 17.9 11.8 0.4 0 0.4 0.4 355 4 354 305 11 0 11 0 -3.2 0 -3.1 -3.3 05/03/2005 20:40:00 14.9 1.4 17.6 10.7 15 1.4 18.3 11.1 0.4 0 0.4 0.4 354 5 351 305 12 0 12 0 -3.3 0 -3.1 -3.3 05/03/2005 20:50:00 16 1.3 19.5 11.5 16.2 1.3 19.5 12.2 0.4 0 0.4 0.4 356 5 353 305 12 0 12 0 -3.3 0 -3.3 -3.6 05/03/2005 21:00:00 16 1.5 19.1 10.7 16.1 1.6 19.5 12.2 0.4 0 0.4 0.4 356 4 357 305 12 0 12 0 -3.4 0 -3.3 -3.6 05/03/2005 21:10:00 15.6 1.3 17.9 11.5 15.5 1.3 18.7 11.5 0.4 0 0.4 0.4 354 5 346 305 12 0 12 0 -3.4 0 -3.3 -3.6 05/03/2005 21:20:00 16.5 1.6 19.9 11.8 16.5 1.7 20.2 11.5 0.4 0 0.4 0.4 355 4 355 305 13 0 13 0 -3.5 0 -3.3 -3.6 05/03/2005 21:30:00 17.3 1.6 21 13 17.3 1.7 21 13 0.4 0 0.4 0.4 357 4 0 305 13 0 13 0 -3.6 0 -3.3 -3.8 05/03/2005 21:40:00 16.4 1.6 19.5 11.8 16.4 1.7 19.9 12.6 0.4 0 0.4 0.4 355 5 357 305 13 0 13 0 -3.5 0 -3.3 -3.6 05/03/2005 21:50:00 15.6 1.5 19.1 12.2 15.8 1.5 19.5 12.2 0.4 0 0.4 0.4 353 5 349 305 13 0 13 0 -3.4 0 -3.3 -3.8 05/03/2005 22:00:00 17.1 1.3 19.5 13.3 17.2 1.3 20.2 13 0.4 0 0.4 0.4 349 4 352 305 14 0 14 0 -3.6 0.1 -3.3 -3.8 05/03/2005 22:10:00 16.2 1.5 18.7 12.2 16.5 1.6 19.9 12.6 0.4 0 0.4 0.4 347 3 347 305 14 0 14 0 -3.7 0 -3.6 -3.8 05/03/2005 22:20:00 14.6 1.4 17.2 10.7 14.7 1.5 17.6 11.1 0.4 0 0.4 0.4 343 4 338 305 14 0 14 0 -3.7 0.1 -3.3 -3.8 05/03/2005 22:30:00 15.8 1.2 18.7 12.2 15.9 1.3 18.7 11.1 0.4 0 0.4 0.4 351 4 350 305 14 0 14 0 -3.8 0 -3.6 -3.8 05/03/2005 22:40:00 16.2 1.4 19.5 11.5 16.3 1.5 19.5 11.8 0.4 0 0.4 0.4 356 5 359 305 14 0 14 0 -3.9 0 -3.8 -4 05/03/2005 22:50:00 15.1 1.5 18.3 11.8 15.2 1.5 18.7 12.2 0.4 0 0.4 0.4 355 6 356 305 15 0 14 0 -3.9 0 -3.8 -4 05/03/2005 23:00:00 15.5 1.1 18.3 11.8 15.5 1.2 18.3 11.8 0.4 0 0.4 0.4 351 4 354 305 15 0 15 0 -4 0 -3.8 -4.2 05/03/2005 23:10:00 14.9 1.2 17.9 11.8 15 1.3 18.3 11.1 0.4 0 0.4 0.4 354 4 354 305 15 0 15 0 -4 0 -3.8 -4.2 05/03/2005 23:20:00 15.1 1.4 17.6 11.1 15.1 1.4 17.6 11.1 0.4 0 0.4 0.4 354 5 350 305 15 0 15 0 -3.9 0 -3.8 -4 05/03/2005 23:30:00 15.6 1.2 17.9 11.1 15.6 1.3 18.3 11.8 0.4 0 0.4 0.4 358 4 1 305 15 0 15 0 -4 0 -3.8 -4 05/03/2005 23:40:00 15.8 1.1 17.6 12.2 15.9 1.3 18.3 11.8 0.4 0 0.4 0.4 354 4 350 305 15 0 15 0 -4 0 -3.6 -4.2 05/03/2005 23:50:00 14.3 1.5 17.6 10.3 14.3 1.5 17.6 9.9 0.4 0 0.4 0.4 353 5 356 305 16 0 15 0 -4 0 -3.8 -4 05/04/2005 00:00:00 15.2 1.1 17.9 12.2 15.4 1.2 17.9 12.2 0.4 0 0.4 0.4 354 5 352 305 16 0 16 0 -4 0 -3.6 -4 05/04/2005 00:10:00 15.5 1.5 18.3 11.8 15.6 1.6 18.7 11.1 0.4 0 0.4 0.4 349 4 349 305 16 0 16 0 -4.1 0.1 -3.8 -4.5 05/04/2005 00:20:00 15 1.3 17.6 11.5 15 1.4 18.3 11.8 0.4 0 0.4 0.4 350 5 347 305 16 0 16 0 -4.2 0 -4 -4.5 05/04/2005 00:30:00 14.8 1.5 17.6 10.7 14.8 1.5 17.9 10.7 0.4 0 0.4 0.4 353 5 351 305 16 0 16 0 -4.2 0 -3.8 -4.5 05/04/2005 00:40:00 15.6 1.2 17.9 12.2 15.7 1.3 17.9 11.8 0.4 0 0.4 0.4 355 4 357 305 17 0 16 0 -4.2 0 -4 -4.5 05/04/2005 00:50:00 14.5 1.1 16.8 11.5 14.5 1.2 16.8 11.5 0.4 0 0.4 0.4 356 5 4 305 17 0 17 0 -4.2 0 -4 -4.5 05/04/2005 01:00:00 14.7 1.2 16.8 9.9 14.9 1.3 17.6 9.9 0.4 0 0.4 0.4 353 4 355 305 17 0 17 0 -4.3 0 -4 -4.5 05/04/2005 01:10:00 14.9 1.2 17.2 11.5 15.1 1.3 17.6 11.5 0.4 0 0.4 0.4 353 4 354 305 17 0 17 0 -4.2 0 -4 -4.5 05/04/2005 01:20:00 15.1 1.3 17.6 11.5 15.4 1.3 18.3 11.5 0.4 0 0.4 0.4 352 4 352 305 17 0 17 0 -4.2 0 -4 -4.5 05/04/2005 01:30:00 15 1.3 17.6 11.5 15.1 1.5 18.3 10.3 0.4 0 0.4 0.4 356 4 1 305 18 0 18 0 -4.2 0 -4 -4.5 05/04/2005 01:40:00 14.9 1.4 17.6 10.7 14.9 1.5 18.7 9.9 0.4 0 0.4 0.4 353 5 358 305 18 0 18 0 -4.1 0 -3.6 -4.2 05/04/2005 01:50:00 16.2 1 18.7 11.5 16.3 1 18.7 12.6 0.4 0 0.4 0.4 351 4 345 305 18 0 18 0 -4.2 0 -4 -4.5 05/04/2005 02:00:00 15.3 1.3 17.6 11.5 15.4 1.4 18.3 11.8 0.4 0 0.4 0.4 352 4 350 305 18 0 18 0 -4.2 0.1 -3.8 -4.5 05/04/2005 02:10:00 15.9 1.4 18.7 11.5 15.9 1.5 18.7 11.1 0.4 0 0.4 0.4 352 4 351 305 17 0 18 0 -4.2 0 -4 -4.5 05/04/2005 02:20:00 14.6 1.7 17.9 10.7 14.8 1.8 18.3 10.3 0.4 0 0.4 0.4 354 5 358 305 18 0 18 0 -4.1 0 -3.8 -4.2 05/04/2005 02:30:00 15 1.2 17.6 11.8 15.1 1.4 18.3 11.1 0.4 0 0.4 0.4 356 4 355 305 18 0 18 0 -4.2 0 -3.8 -4.5 05/04/2005 02:40:00 15.4 1 17.6 12.6 15.5 1.1 17.6 11.8 0.4 0 0.4 0.4 355 4 357 305 18 0 18 0 -4.2 0 -4 -4.2 05/04/2005 02:50:00 14.6 1.1 17.2 11.8 14.7 1.2 17.2 11.1 0.4 0 0.4 0.4 357 4 1 305 17 0 18 0 -4.1 0 -4 -4.2 05/04/2005 03:00:00 13.9 1.2 16.4 10.3 14 1.3 16.8 10.7 0.4 0 0.4 0.4 353 5 357 305 17 0 18 0 -4.2 0 -4 -4.5 05/04/2005 03:10:00 13.4 1.3 16.1 9.5 13.5 1.4 16.4 9.9 0.4 0 0.4 0.4 351 4 353 305 17 0 18 0 -4.3 0 -4 -4.5 05/04/2005 03:20:00 13.3 1.1 15.6 10.7 13.5 1.1 16.1 10.3 0.4 0 0.4 0.4 348 6 353 305 18 0 18 0 -4.2 0 -4 -4.5 05/04/2005 03:30:00 13.5 1 15.6 10.3 13.8 1.1 16.4 11.1 0.4 0 0.4 0.4 349 5 345 305 18 0 18 0 -4.4 0 -4.2 -4.7 05/04/2005 03:40:00 13.3 1.2 15.6 9.5 13.5 1.2 16.1 9.9 0.4 0 0.4 0.4 354 4 350 305 18 0 18 0 -4.4 0 -4 -4.5 05/04/2005 03:50:00 13.3 1.1 15.6 9.9 13.5 1.2 16.1 9.9 0.4 0 0.4 0.4 355 3 356 305 18 0 18 0 -4.3 0 -4 -4.5 05/04/2005 04:00:00 13.4 0.8 15.3 11.1 13.6 0.8 15.6 11.1 0.4 0 0.4 0.4 353 3 350 305 18 0 18 0 -4.3 0 -3.8 -4.5 05/04/2005 04:10:00 13.1 1 14.9 10.3 13.2 1.1 15.6 9.9 0.4 0 0.4 0.4 356 4 356 305 18 0 18 0 -4.2 0 -4 -4.5 05/04/2005 04:20:00 14.3 0.7 16.1 11.8 14.5 0.8 16.1 11.5 0.4 0 0.4 0.4 356 3 356 305 18 0 18 0 -4.2 0 -4 -4.5 05/04/2005 04:30:00 14.2 1 16.1 10.7 14.4 1 16.4 11.5 0.4 0 0.4 0.4 358 4 359 305 18 0 18 0 -4.2 0 -4 -4.5 05/04/2005 04:40:00 14 1 16.1 11.1 14.2 1 16.8 11.5 0.4 0 0.4 0.4 356 4 355 305 18 0 18 0 -4.1 0 -3.8 -4.2 05/04/2005 04:50:00 14.3 1 16.8 11.5 14.4 1.1 16.8 11.1 0.4 0 0.4 0.4 0 4 1 305 18 0 18 0 -4 0 -3.8 -4.2 05/04/2005 05:00:00 14.2 1 16.4 11.1 14.3 1.1 17.2 11.5 0.4 0 0.4 0.4 357 5 353 305 18 0 18 0 -4.2 0.1 -3.8 -4.5 05/04/2005 05:10:00 14.7 1 17.2 11.5 14.9 1.1 17.6 11.5 0.4 0 0.4 0.4 352 4 348 305 18 0 18 0 -4.4 0 -4.2 -4.7 05/04/2005 05:20:00 14 1.5 17.2 9.9 14.1 1.7 17.6 9.9 0.4 0 0.4 0.4 354 5 349 305 18 0 18 0 -4.4 0.1 -4 -4.7 05/04/2005 05:30:00 13.9 1.2 16.1 10.7 14 1.2 16.8 10.3 0.4 0 0.4 0.4 357 4 355 305 18 0 19 0 -4.3 0 -4 -4.5 05/04/2005 05:40:00 14.5 1 17.2 11.8 14.5 1.2 17.6 11.5 0.4 0 0.4 0.4 358 3 358 305 19 0 19 0 -4.2 0 -3.8 -4.5 05/04/2005 05:50:00 14.6 1 17.2 11.5 14.8 1.1 17.6 11.5 0.4 0 0.4 0.4 354 4 352 305 19 0 19 0 -4.2 0 -4 -4.5 05/04/2005 06:00:00 14.3 1.2 16.8 11.1 14.4 1.3 17.2 11.1 0.4 0 0.4 0.4 356 4 354 305 19 0 19 0 -4.2 0 -4 -4.5 05/04/2005 06:10:00 14.4 1 16.4 11.8 14.6 1.1 16.8 11.5 0.4 0 0.4 0.4 357 3 356 305 19 0 19 0 -4.2 0 -4 -4.5 05/04/2005 06:20:00 14.1 1 16.4 11.8 14.1 1.1 16.8 11.5 0.4 0 0.4 0.4 357 5 359 305 19 0 19 0 -4.1 0 -3.8 -4.2 05/04/2005 06:30:00 13.9 1.2 16.1 9.9 14.2 1.3 17.2 10.3 0.4 0 0.4 0.4 356 4 358 305 19 0 19 0 -4.1 0 -3.8 -4.2 05/04/2005 06:40:00 14.5 1 16.8 11.5 14.7 1.1 17.9 10.7 0.4 0 0.4 0.4 359 4 1 305 19 0 19 0 -4.1 0 -4 -4.2 05/04/2005 06:50:00 14.1 1 16.1 10.7 14.3 1.1 16.4 10.7 0.4 0 0.4 0.4 0 4 3 305 19 0 19 0 -4.1 0 -4 -4.2 05/04/2005 07:00:00 13.9 1.2 16.1 10.3 13.9 1.3 16.4 10.3 0.4 0 0.4 0.4 355 4 355 305 19 0 19 0 -4.1 0 -3.8 -4.2 05/04/2005 07:10:00 14.3 1.3 16.8 10.3 14.5 1.3 17.6 9.9 0.4 0 0.4 0.4 356 4 354 305 19 0 19 0 -4.1 0 -3.8 -4.2 05/04/2005 07:20:00 14.5 0.8 16.8 11.8 14.6 1 17.2 10.7 0.4 0 0.4 0.4 356 4 352 305 19 0 19 0 -4.2 0 -4 -4.5 05/04/2005 07:30:00 14.1 1 17.2 10.3 14.3 1.2 17.2 11.5 0.4 0 0.4 0.4 357 4 358 305 19 0 19 0 -4.2 0 -4 -4.5 05/04/2005 07:40:00 13.6 1 16.4 10.7 13.7 1.2 17.2 10.3 0.4 0 0.4 0.4 359 5 352 305 19 0 19 0 -4.2 0 -4 -4.5 05/04/2005 07:50:00 13.7 1 16.4 11.5 13.7 1.1 16.1 11.1 0.4 0 0.4 0.4 1 5 7 305 19 0 19 0 -4.1 0 -4 -4.2 05/04/2005 08:00:00 13.9 1 16.4 10.7 14.1 1.1 16.4 10.3 0.4 0 0.4 0.4 357 5 359 305 19 0 19 0 -4 0 -3.8 -4.2 05/04/2005 08:10:00 13.8 1 15.6 11.1 14 1.2 16.4 11.1 0.4 0 0.4 0.4 353 3 345 305 19 0 19 0 -3.9 0 -3.8 -4 05/04/2005 08:20:00 13.7 1 15.6 10.3 13.9 1 16.1 11.1 0.4 0 0.4 0.4 357 5 3 305 19 0 19 0 -4 0 -3.3 -4 05/04/2005 08:30:00 13.8 1.2 16.4 10.7 14 1.3 16.8 10.7 0.4 0 0.4 0.4 357 4 352 305 19 0 19 0 -4 0 -3.8 -4.2 05/04/2005 08:40:00 13.9 1 16.1 11.1 14.1 1 16.1 11.5 0.4 0 0.4 0.4 359 4 353 305 19 0 18 0 -3.9 0 -3.6 -4 05/04/2005 08:50:00 13.6 1.1 16.4 10.3 13.8 1.2 16.8 10.3 0.4 0 0.4 0.4 3 4 2 305 19 0 19 0 -3.9 0 -3.3 -4 05/04/2005 09:00:00 13.8 1 16.1 10.7 14 1.1 16.4 11.1 0.4 0 0.4 0.4 359 4 358 305 18 0 18 0 -3.9 0 -3.8 -4 05/04/2005 09:10:00 13.7 1 15.6 11.1 13.8 1.1 16.1 10.7 0.4 0 0.4 0.4 2 4 3 305 18 0 18 0 -3.9 0 -3.8 -4 05/04/2005 09:20:00 13.7 1.1 16.1 10.3 13.8 1.2 16.8 10.3 0.4 0 0.4 0.4 3 4 2 305 18 0 18 0 -3.9 0 -3.8 -4 05/04/2005 09:30:00 14.3 0.9 16.8 11.5 14.5 1 16.8 11.5 0.4 0 0.4 0.4 1 4 3 305 18 0 18 0 -3.9 0 -3.8 -4 05/04/2005 09:40:00 13.6 0.9 15.3 11.5 13.7 1 16.1 11.1 0.4 0 0.4 0.4 0 4 0 305 18 0 18 0 -3.9 0 -3.8 -4 05/04/2005 09:50:00 13.4 1 15.6 9.5 13.5 1.1 16.1 10.7 0.4 0 0.4 0.4 359 4 358 305 18 0 18 0 -3.7 0 -3.6 -3.8 05/04/2005 10:00:00 13.4 1.1 16.1 10.7 13.5 1.1 16.1 10.3 0.4 0 0.4 0.4 358 4 357 305 18 0 18 0 -3.8 0 -3.3 -3.8 05/04/2005 10:10:00 12.8 1.1 15.6 9.5 13 1.2 15.6 9.9 0.4 0 0.4 0.4 358 5 2 305 17 0 18 0 -3.8 0 -3.3 -4 05/04/2005 10:20:00 13.3 0.8 15.6 11.5 13.4 1 15.6 10.7 0.4 0 0.4 0.4 7 5 12 305 18 0 18 0 -3.8 0 -3.3 -4 05/04/2005 10:30:00 13.7 1.3 16.1 10.3 13.8 1.2 16.4 9.9 0.4 0 0.4 0.4 10 4 10 305 18 0 18 0 -3.9 0 -3.6 -4 05/04/2005 10:40:00 13.2 1 15.3 10.3 13.2 1 15.6 10.3 0.4 0 0.4 0.4 8 4 6 305 17 0 18 0 -3.9 0 -3.6 -4 05/04/2005 10:50:00 13.2 1 15.6 10.7 13.3 1.1 15.6 9.9 0.4 0 0.4 0.4 5 4 2 305 17 0 17 0 -3.9 0 -3.6 -4 05/04/2005 11:00:00 12.9 0.9 14.9 10.3 13 1 15.3 10.3 0.4 0 0.4 0.4 8 5 8 305 18 0 18 0 -3.8 0 -3.6 -3.8 05/04/2005 11:10:00 12.6 1 15.3 9.9 12.7 1.1 15.6 9.1 0.4 0 0.4 0.4 8 5 1 305 18 0 18 0 -3.6 0 -3.3 -3.8 05/04/2005 11:20:00 13.1 1.1 16.8 9.9 13.1 1.2 16.8 9.5 0.4 0 0.4 0.4 15 5 6 305 18 0 18 0 -3.4 0 -3.1 -3.8 05/04/2005 11:30:00 13.9 1 16.1 10.7 14 1.1 16.4 10.7 0.4 0 0.4 0.4 13 4 9 305 17 0 17 0 -3.5 0 -3.3 -3.8 05/04/2005 11:40:00 12.4 1.1 14.9 9.9 12.3 1.2 14.9 8.8 0.4 0 0.4 0.4 17 6 17 305 17 0 17 0 -3.3 0 -3.1 -3.3 05/04/2005 11:50:00 13.4 1.3 16.1 9.9 13.4 1.3 16.1 9.5 0.4 0 0.4 0.4 21 5 25 305 17 0 17 0 -3.4 0 -3.1 -3.6 05/04/2005 12:00:00 12.7 0.9 14.9 10.7 12.7 1 15.3 9.9 0.4 0 0.4 0.4 17 5 29 305 16 0 16 0 -3.3 0 -3.1 -3.3 05/04/2005 12:10:00 13.6 0.8 15.3 11.8 13.7 0.9 15.6 11.1 0.4 0 0.4 0.4 20 5 17 305 15 0 15 0 -3.5 0 -3.3 -3.6 05/04/2005 12:20:00 13.2 0.9 15.6 10.7 13.1 1 15.6 9.5 0.4 0 0.4 0.4 20 5 21 305 15 0 15 0 -3.5 0 -3.3 -3.8 05/04/2005 12:30:00 12.9 1 15.3 9.9 12.9 1.2 15.3 9.5 0.4 0 0.4 0.4 20 6 13 305 15 0 14 0 -3.6 0 -3.3 -3.8 05/04/2005 12:40:00 12.7 1.1 14.9 9.9 12.6 1.2 14.9 8.4 0.4 0 0.4 0.4 18 5 19 305 15 0 15 0 -3.5 0 -3.3 -3.8 05/04/2005 12:50:00 13 0.9 14.9 10.3 13 1 15.6 9.5 0.4 0 0.4 0.4 16 4 13 305 14 0 14 0 -3.6 0 -3.3 -3.8 05/04/2005 13:00:00 13.2 1 15.6 9.9 13.1 1.1 15.6 10.3 0.4 0 0.4 0.4 20 5 23 305 15 0 14 0 -3.6 0.1 -3.3 -3.8 05/04/2005 13:10:00 13.3 1.1 16.4 9.9 13.4 1.3 16.8 9.1 0.4 0 0.4 0.4 18 5 17 305 14 0 14 0 -3.7 0 -3.3 -3.8 05/04/2005 13:20:00 13.9 0.8 16.4 10.7 13.9 1 16.1 9.9 0.4 0 0.4 0.4 22 3 21 305 15 0 15 0 -3.6 0 -3.3 -3.8 05/04/2005 13:30:00 14 0.8 16.4 11.5 14 1 16.4 11.5 0.4 0 0.4 0.4 20 5 15 305 15 0 14 0 -3.5 0 -3.3 -3.8 05/04/2005 13:40:00 12.7 1 15.3 9.5 12.8 1.1 15.6 9.5 0.4 0 0.4 0.4 21 5 22 305 15 0 14 0 -3.6 0.2 -3.3 -3.8 05/04/2005 13:50:00 12 1 14.1 8.4 12 1.1 14.1 7.6 0.4 0 0.4 0.4 22 5 22 305 15 0 15 0 -3.6 0 -3.3 -3.8 05/04/2005 14:00:00 12.2 1.3 15.3 8.4 12.2 1.4 15.3 8.4 0.4 0 0.4 0.4 24 4 22 305 15 0 15 0 -3.7 0.1 -3.3 -3.8 05/04/2005 14:10:00 13.1 0.9 14.9 10.7 13 1 14.9 10.3 0.4 0 0.4 0.4 25 4 29 305 15 0 15 0 -3.7 0 -3.6 -3.8 05/04/2005 14:20:00 13.2 0.8 14.9 11.1 13.1 0.9 15.3 10.3 0.4 0 0.4 0.4 25 3 27 305 15 0 15 0 -3.6 0 -3.3 -3.8 05/04/2005 14:30:00 12.8 1 15.3 9.9 12.8 1 15.3 9.9 0.4 0 0.4 0.4 22 6 37 305 15 0 15 0 -3.7 0 -3.3 -3.8 05/04/2005 14:40:00 13 0.8 14.9 10.7 13 0.9 15.3 10.7 0.4 0 0.4 0.4 21 5 18 305 15 0 15 0 -3.8 0 -3.6 -3.8 05/04/2005 14:50:00 12.9 1 14.9 9.5 13 1 15.3 9.5 0.4 0 0.4 0.4 20 4 19 305 15 0 15 0 -3.9 0 -3.3 -4 05/04/2005 15:00:00 12.9 0.8 14.5 10.7 13 0.9 14.9 9.9 0.4 0 0.4 0.4 22 6 20 305 15 0 15 0 -3.8 0 -3.6 -4 05/04/2005 15:10:00 12.9 0.8 15.3 10.7 12.9 0.8 14.9 9.9 0.4 0 0.4 0.4 26 7 26 305 15 0 15 0 -3.9 0 -3.8 -4 05/04/2005 15:20:00 13 0.9 14.9 10.3 13 1 14.9 9.9 0.4 0 0.4 0.4 25 9 13 305 15 0 14 0 -3.9 0 -3.6 -4 05/04/2005 15:30:00 12.7 1 15.3 9.5 12.6 1.1 15.6 9.5 0.4 0 0.4 0.4 28 6 41 305 15 0 15 0 -3.9 0 -3.6 -4 05/04/2005 15:40:00 12.8 1 14.9 10.3 12.7 1.1 15.3 9.5 0.4 0 0.4 0.4 27 4 25 305 15 0 15 0 -4 0 -3.8 -4 05/04/2005 15:50:00 12.2 0.8 14.5 10.3 12.2 1 14.1 9.5 0.4 0 0.4 0.4 24 8 30 305 15 0 15 0 -3.9 0 -3.8 -4 05/04/2005 16:00:00 12.7 1.1 15.3 9.9 12.7 1.2 15.3 9.1 0.4 0 0.4 0.4 19 6 25 305 15 0 15 0 -3.9 0 -3.8 -4 05/04/2005 16:10:00 11.9 0.8 13.7 9.1 11.9 0.9 14.1 8.4 0.4 0 0.4 0.4 16 4 19 305 14 0 14 0 -3.9 0 -3.6 -4 05/04/2005 16:20:00 11.6 0.7 13 9.1 11.6 0.8 13.3 9.1 0.4 0 0.4 0.4 23 6 21 305 14 0 14 0 -4 0 -3.8 -4 05/04/2005 16:30:00 11.4 0.8 13 9.1 11.4 0.9 13.3 9.1 0.4 0 0.4 0.4 28 5 34 305 14 0 14 0 -4.1 0.1 -3.8 -4.5 05/04/2005 16:40:00 11.3 1 13.3 8.8 11.2 1 13.3 8.4 0.4 0 0.4 0.4 30 5 33 305 14 0 14 0 -4.3 0 -4 -4.5 05/04/2005 16:50:00 11.5 1 14.9 9.1 11.4 1 14.1 8.4 0.4 0 0.4 0.4 25 8 33 305 14 0 14 0 -4.3 0 -4 -4.5 05/04/2005 17:00:00 12.3 1 14.5 9.5 12.2 1 14.5 9.5 0.4 0 0.4 0.4 29 5 28 305 15 0 15 0 -4.4 0 -4 -4.7 05/04/2005 17:10:00 11.8 0.8 14.1 9.9 11.7 0.9 14.1 9.5 0.4 0 0.4 0.4 24 4 18 305 15 0 15 0 -4.4 0 -4.2 -4.7 05/04/2005 17:20:00 11.5 1.1 13.7 8.4 11.5 1.1 14.1 8.8 0.4 0 0.4 0.4 21 5 24 305 15 0 15 0 -4.4 0 -3.8 -4.7 05/04/2005 17:30:00 11.4 1.1 14.1 9.1 11.4 1.1 14.1 8.8 0.4 0 0.4 0.4 21 5 27 305 15 0 15 0 -4.4 0 -4.2 -4.7 05/04/2005 17:40:00 11.2 0.9 13.3 8.8 11.2 0.9 13.3 8 0.4 0 0.4 0.4 23 8 17 305 15 0 15 0 -4.4 0 -4.2 -4.7 05/04/2005 17:50:00 11 1 13 8.4 11 1 13.3 8.4 0.4 0 0.4 0.4 23 5 32 305 16 0 16 0 -4.4 0 -4.2 -4.7 05/04/2005 18:00:00 11.5 0.9 13.3 8.8 11.4 1 13.7 8.8 0.4 0 0.4 0.4 29 6 25 305 17 0 16 0 -4.4 0 -4.2 -4.7 05/04/2005 18:10:00 12.1 1 14.1 8.8 12 1 14.5 8.8 0.4 0 0.4 0.4 27 5 26 305 17 0 17 0 -4.5 0 -4.2 -4.7 05/04/2005 18:20:00 11.8 0.9 14.1 9.1 11.7 1 14.1 8.8 0.4 0 0.4 0.4 29 5 38 305 17 0 17 0 -4.4 0 -4.2 -4.7 05/04/2005 18:30:00 11.9 0.8 13.7 9.5 12 0.9 13.7 9.1 0.4 0 0.4 0.4 29 6 33 305 16 0 16 0 -4.4 0 -4.2 -4.7 05/04/2005 18:40:00 11.4 0.9 13.7 8.4 11.3 1 13.3 8 0.4 0 0.4 0.4 31 5 23 305 16 0 16 0 -4.5 0 -4.2 -4.7 05/04/2005 18:50:00 11.8 0.7 13.7 9.1 11.8 0.8 13.7 9.1 0.4 0 0.4 0.4 23 5 21 305 17 0 16 0 -4.6 0 -4.2 -4.7 05/04/2005 19:00:00 11 0.9 13.3 8 11 1 13.3 8.4 0.4 0 0.4 0.4 28 4 30 305 17 0 17 0 -4.4 0 -4.2 -4.7 05/04/2005 19:10:00 11.5 0.7 13 9.5 11.4 0.8 13 9.1 0.4 0 0.4 0.4 29 8 21 305 17 0 17 0 -4.6 0 -4.5 -4.7 05/04/2005 19:20:00 11 0.7 12.6 9.1 11 0.7 12.6 8.8 0.4 0 0.4 0.4 27 4 28 305 18 0 18 0 -4.6 0 -4.5 -4.7 05/04/2005 19:30:00 11 0.7 13 8.8 11.1 0.8 13 8.8 0.4 0 0.4 0.4 28 5 36 305 18 0 18 0 -4.7 0 -4.5 -4.9 05/04/2005 19:40:00 10.6 0.6 12.6 8.8 10.6 0.6 12.6 8.8 0.4 0 0.4 0.4 28 4 29 305 18 0 18 0 -4.6 0 -4.5 -4.7 05/04/2005 19:50:00 10.4 0.8 12.6 8.4 10.4 1 12.6 7.6 0.4 0 0.4 0.4 26 6 27 305 18 0 18 0 -4.6 0 -4.5 -4.7 05/04/2005 20:00:00 10.5 0.7 12.2 8.8 10.5 0.8 12.2 8 0.4 0 0.4 0.4 23 5 22 305 19 0 18 0 -4.6 0 -4.5 -4.7 05/04/2005 20:10:00 10.9 0.6 13 9.5 11 0.7 12.2 8.8 0.4 0 0.4 0.4 24 6 15 305 20 0 19 0 -4.6 0 -4.5 -4.7 05/04/2005 20:20:00 11 0.6 12.6 9.1 11 0.8 13 8.8 0.4 0 0.4 0.4 25 5 20 305 20 0 20 0 -4.6 0 -4.5 -4.7 05/04/2005 20:30:00 10.9 0.6 12.2 9.1 10.9 0.7 12.6 9.1 0.4 0 0.4 0.4 26 7 16 305 21 0 21 0 -4.6 0 -4.5 -4.7 05/04/2005 20:40:00 11.1 0.7 12.2 8.8 11.1 0.8 12.6 8.8 0.4 0 0.4 0.4 28 5 34 305 22 0 22 0 -4.5 0 -4.5 -4.7 05/04/2005 20:50:00 11.2 0.8 13 8.8 11.3 0.9 13 8.4 0.4 0 0.4 0.4 24 4 23 305 22 0 22 0 -4.4 0 -4.2 -4.7 05/04/2005 21:00:00 11.4 0.7 13.3 9.5 11.5 0.7 13.3 9.5 0.4 0 0.4 0.4 24 4 26 305 23 0 23 0 -4.4 0 -4.2 -4.7 05/04/2005 21:10:00 11.2 0.7 12.6 8.8 11.2 0.9 13 8.4 0.4 0 0.4 0.4 28 4 30 305 24 0 24 0 -4.4 0 -4.2 -4.5 05/04/2005 21:20:00 11.2 0.7 12.6 9.1 11.2 0.7 13.3 8.8 0.4 0 0.4 0.4 25 4 28 305 25 0 25 0 -4.4 0 -4 -4.5 05/04/2005 21:30:00 10.9 0.8 13 8.8 10.9 0.9 13.3 8.8 0.4 0 0.4 0.4 25 5 26 305 26 0 26 0 -4.2 0 -4 -4.5 05/04/2005 21:40:00 11 0.7 12.2 8.8 11 0.8 12.6 8.4 0.4 0 0.4 0.4 23 4 22 305 27 0 27 0 -4.2 0 -4 -4.5 05/04/2005 21:50:00 11 0.6 12.6 9.5 11.2 0.7 13 9.5 0.4 0 0.4 0.4 23 4 24 305 28 0 28 0 -4.2 0 -4 -4.5 05/04/2005 22:00:00 11.4 0.6 12.6 9.5 11.5 0.7 13 9.5 0.4 0 0.4 0.4 22 5 18 305 29 0 29 0 -4.2 0 -4 -4.5 05/04/2005 22:10:00 11.3 0.7 13 9.1 11.4 0.8 13.3 9.1 0.4 0 0.4 0.4 20 4 22 305 30 0 30 0 -4.2 0 -4 -4.5 05/04/2005 22:20:00 11.3 0.9 13 8.8 11.4 1 13 8.8 0.4 0 0.4 0.4 21 3 21 305 31 0 31 0 -4.2 0 -4 -4.5 05/04/2005 22:30:00 11.2 0.8 13 9.5 11.2 0.8 13.3 8.8 0.4 0 0.4 0.4 22 4 21 305 33 0 32 0 -4.2 0 -3.8 -4.5 05/04/2005 22:40:00 11.6 0.7 13.3 9.5 11.7 0.8 13.3 9.9 0.4 0 0.4 0.4 24 5 30 305 34 0 34 0 -4.2 0 -4 -4.5 05/04/2005 22:50:00 11.5 0.8 13.3 9.5 11.5 0.8 14.1 9.5 0.4 0 0.4 0.4 25 4 27 305 35 0 35 0 -4.3 0 -4 -4.5 05/04/2005 23:00:00 11.3 0.7 13 9.5 11.4 0.8 13 9.5 0.4 0 0.4 0.4 22 4 21 305 36 0 36 0 -4.2 0 -3.8 -4.5 05/04/2005 23:10:00 11.5 0.8 13 9.1 11.6 0.9 13.3 8.8 0.4 0 0.4 0.4 24 5 17 305 37 0 36 0 -4.2 0 -4 -4.5 05/04/2005 23:20:00 11.5 0.6 13 9.5 11.5 0.7 13 9.5 0.4 0 0.4 0.4 24 5 23 305 38 0 38 0 -4.1 0 -4 -4.2 05/04/2005 23:30:00 11.7 0.8 13.3 9.5 11.8 0.9 13.7 9.5 0.4 0 0.4 0.4 24 3 24 305 39 0 39 0 -4.2 0.1 -4 -4.5 05/04/2005 23:40:00 11.8 0.7 13.3 9.9 12 0.8 13.7 9.5 0.4 0 0.4 0.4 22 4 18 305 40 0 40 0 -4.2 0 -4 -4.5 05/04/2005 23:50:00 11.7 0.6 13 9.5 11.8 0.7 13.3 9.9 0.4 0 0.4 0.4 22 4 19 305 41 0 41 0 -4.2 0 -4 -4.5 05/05/2005 00:00:00 11.4 0.8 13 9.5 11.4 0.8 13 9.5 0.4 0 0.4 0.4 22 5 29 305 42 0 42 0 -4.2 0 -3.8 -4.5 05/05/2005 00:10:00 11.5 0.7 13 9.1 11.5 0.8 13.3 9.1 0.4 0 0.4 0.4 23 4 16 305 43 0 42 0 -4.3 0 -4 -4.5 05/05/2005 00:20:00 11.7 0.7 13 9.5 11.6 0.8 13.3 8.8 0.4 0 0.4 0.4 23 4 22 305 44 0 44 0 -4.2 0 -4 -4.5 05/05/2005 00:30:00 11.6 0.8 13.3 9.1 11.6 0.8 13.3 9.1 0.4 0 0.4 0.4 22 3 24 305 45 0 45 0 -4.3 0 -4 -4.5 05/05/2005 00:40:00 11.4 0.7 13 9.1 11.5 0.8 13 9.5 0.4 0 0.4 0.4 22 4 20 305 46 0 46 0 -4.3 0 -4 -4.5 05/05/2005 00:50:00 11.5 0.6 13 9.5 11.6 0.7 13.3 9.1 0.4 0 0.4 0.4 21 4 15 305 46 0 46 0 -4.3 0 -4 -4.5 05/05/2005 01:00:00 11.8 0.7 13 9.5 11.8 0.8 13.3 9.1 0.4 0 0.4 0.4 23 4 22 305 47 0 47 0 -4.3 0 -4 -4.5 05/05/2005 01:10:00 11.8 0.8 13.7 9.9 11.8 0.8 13.7 9.5 0.4 0 0.4 0.4 20 3 19 305 48 0 47 0 -4.3 0 -4 -4.5 05/05/2005 01:20:00 11.2 0.7 12.6 9.1 11.3 0.9 13 8.8 0.4 0 0.4 0.4 22 4 19 305 49 0 48 0 -4.4 0 -4.2 -4.5 05/05/2005 01:30:00 11.6 0.6 13 9.1 11.7 0.8 13 8.4 0.4 0 0.4 0.4 20 4 20 305 49 0 49 0 -4.4 0 -4 -4.5 05/05/2005 01:40:00 11.8 0.7 13 9.5 11.8 0.8 13.3 9.1 0.4 0 0.4 0.4 20 4 21 305 50 0 50 0 -4.4 0 -4.2 -4.5 05/05/2005 01:50:00 11.7 0.5 13 9.9 11.8 0.6 13.3 9.9 0.4 0 0.4 0.4 19 3 21 305 50 0 50 0 -4.4 0 -4.2 -4.7 05/05/2005 02:00:00 11.2 0.8 13 9.1 11.2 0.9 13.7 9.1 0.4 0 0.4 0.4 23 4 19 305 51 0 51 0 -4.3 0 -4 -4.5 05/05/2005 02:10:00 11.7 0.7 13.3 9.5 11.7 0.9 13.3 9.1 0.4 0 0.4 0.4 19 4 24 305 52 0 52 0 -4.3 0 -4 -4.5 05/05/2005 02:20:00 12.1 0.7 13.7 9.9 12.2 0.8 13.7 9.9 0.4 0 0.4 0.4 20 3 17 305 52 0 52 0 -4.4 0 -4.2 -4.5 05/05/2005 02:30:00 11.6 1 13.7 9.1 11.6 1 14.5 9.1 0.4 0 0.4 0.4 18 4 21 305 52 0 53 0 -4.3 0 -4 -4.5 05/05/2005 02:40:00 12.7 0.7 14.1 9.1 12.7 0.9 14.9 9.5 0.4 0 0.4 0.4 18 4 11 305 53 0 53 0 -4.4 0 -3.8 -4.5 05/05/2005 02:50:00 12.4 0.7 13.7 10.3 12.5 0.8 14.5 9.1 0.4 0 0.4 0.4 20 3 25 305 53 0 53 0 -4.4 0 -4 -4.7 05/05/2005 03:00:00 12.7 0.8 14.5 9.9 12.7 0.9 14.5 9.9 0.4 0 0.4 0.4 18 3 18 305 54 0 53 0 -4.4 0 -4.2 -4.7 05/05/2005 03:10:00 12.6 0.9 14.9 9.9 12.7 1 15.3 9.5 0.4 0 0.4 0.4 16 3 17 305 54 0 54 0 -4.5 0 -4.2 -4.7 05/05/2005 03:20:00 12.8 0.8 14.5 10.3 12.8 1 14.9 9.9 0.4 0 0.4 0.4 16 3 19 305 55 0 55 0 -4.5 0 -4.5 -4.7 05/05/2005 03:30:00 12.4 0.8 14.1 9.9 12.5 0.8 14.5 9.1 0.4 0 0.4 0.4 16 3 15 305 55 0 55 0 -4.5 0 -4.5 -4.7 05/05/2005 03:40:00 12.4 1 14.1 8.8 12.4 1 14.1 9.5 0.4 0 0.4 0.4 16 4 17 305 55 0 55 0 -4.5 0 -4.5 -4.7 05/05/2005 03:50:00 12.6 0.8 14.5 10.3 12.7 0.9 14.5 10.3 0.4 0 0.4 0.4 17 3 15 305 56 0 56 0 -4.5 0 -4.5 -4.7 05/05/2005 04:00:00 12.6 0.8 14.1 9.9 12.7 0.9 14.5 10.3 0.4 0 0.4 0.4 13 3 16 305 56 0 56 0 -4.5 0 -4.5 -4.7 05/05/2005 04:10:00 12.5 1.1 14.5 9.1 12.6 1.1 14.5 9.5 0.4 0 0.4 0.4 15 4 10 305 56 0 56 0 -4.5 0 -4.2 -4.7 05/05/2005 04:20:00 12.6 1 14.5 9.5 12.7 1.2 14.9 9.1 0.4 0 0.4 0.4 18 4 18 305 57 0 57 0 -4.5 0 -4.2 -4.7 05/05/2005 04:30:00 12.8 1 14.5 10.3 12.9 1.1 15.3 9.5 0.4 0 0.4 0.4 17 4 13 305 57 0 58 0 -4.4 0 -4.2 -4.7 05/05/2005 04:40:00 12.9 0.7 14.5 10.3 13.1 0.8 14.9 10.7 0.4 0 0.4 0.4 15 4 14 305 57 0 58 0 -4.5 0 -4.5 -4.7 05/05/2005 04:50:00 13.2 0.8 14.9 11.1 13.3 1 15.3 10.3 0.4 0 0.4 0.4 20 4 19 305 58 0 58 0 -4.5 0 -4.5 -4.7 05/05/2005 05:00:00 13.2 0.9 15.3 10.7 13.2 1 15.3 9.9 0.4 0 0.4 0.4 16 4 20 305 58 0 58 0 -4.5 0 -4.5 -4.7 05/05/2005 05:10:00 12.8 1.2 15.3 9.5 12.8 1.3 15.6 9.5 0.4 0 0.4 0.4 21 5 18 305 58 0 58 0 -4.5 0 -4.2 -4.7 05/05/2005 05:20:00 13.1 0.9 15.3 10.7 13 1 15.3 10.3 0.4 0 0.4 0.4 18 4 24 305 59 0 59 0 -4.6 0 -4.5 -4.7 05/05/2005 05:30:00 13.1 1 15.6 9.9 13.1 1.1 16.1 9.9 0.4 0 0.4 0.4 20 5 24 305 59 0 59 0 -4.5 0 -4.5 -4.7 05/05/2005 05:40:00 13.3 0.8 15.3 10.7 13.2 1 16.1 9.9 0.4 0 0.4 0.4 22 4 24 305 59 0 59 0 -4.4 0 -4.2 -4.7 05/05/2005 05:50:00 13.8 0.7 15.6 11.5 13.8 0.9 16.1 10.7 0.4 0 0.4 0.4 23 3 20 305 60 0 60 0 -4.4 0 -4.2 -4.5 05/05/2005 06:00:00 13.2 0.9 15.3 10.7 13.2 1 15.3 10.7 0.4 0 0.4 0.4 23 4 19 305 60 0 60 0 -4.4 0 -4 -4.5 05/05/2005 06:10:00 12.4 0.9 14.5 9.9 12.4 1 14.5 9.9 0.4 0 0.4 0.4 20 4 19 305 61 0 61 0 -4.2 0.1 -4 -4.5 05/05/2005 06:20:00 13 1.1 15.6 9.9 13.1 1.1 16.1 9.9 0.4 0 0.4 0.4 19 3 19 305 61 0 61 0 -4.3 0 -4 -4.5 05/05/2005 06:30:00 13.2 1 15.6 10.3 13.1 1.1 15.6 9.9 0.4 0 0.4 0.4 19 6 30 305 61 0 61 0 -4.2 0 -4 -4.5 05/05/2005 06:40:00 12.7 1 14.9 10.3 12.7 1.1 15.3 9.9 0.4 0 0.4 0.4 19 4 15 305 62 0 62 0 -4.2 0 -3.8 -4.5 05/05/2005 06:50:00 12.8 1 14.9 9.9 12.9 1 15.3 9.9 0.4 0 0.4 0.4 20 6 11 305 62 0 62 0 -4.1 0 -3.8 -4.2 05/05/2005 07:00:00 13.7 0.9 16.1 11.1 13.7 0.9 16.4 11.5 0.4 0 0.4 0.4 16 4 21 305 63 0 63 0 -4.2 0 -4 -4.5 05/05/2005 07:10:00 13.9 1 16.1 11.1 14 1 16.4 11.1 0.4 0 0.4 0.4 16 4 18 305 63 0 63 0 -4.2 0 -4 -4.5 05/05/2005 07:20:00 13.5 1 15.6 10.7 13.6 1 16.1 10.7 0.4 0 0.4 0.4 16 5 14 305 63 0 63 0 -4.1 0 -3.8 -4.2 05/05/2005 07:30:00 13.7 1 16.1 10.7 13.7 1 16.1 10.3 0.4 0 0.4 0.4 16 4 14 305 64 0 64 0 -4.2 0 -4 -4.5 05/05/2005 07:40:00 13.9 1.3 16.4 10.7 13.9 1.4 17.2 9.5 0.4 0 0.4 0.4 16 4 16 305 64 0 65 0 -4.2 0 -4 -4.5 05/05/2005 07:50:00 14.8 1 16.8 11.1 14.8 1.1 16.8 11.1 0.4 0 0.4 0.4 13 3 19 305 65 0 65 0 -4.3 0 -4 -4.5 05/05/2005 08:00:00 14.2 1.3 16.8 10.3 14.2 1.5 17.2 10.7 0.4 0 0.4 0.4 13 4 19 305 65 0 66 0 -4.1 0 -3.8 -4.2 05/05/2005 08:10:00 14.1 1.1 16.4 11.5 14.2 1.1 16.4 11.1 0.4 0 0.4 0.4 16 4 15 305 66 0 66 0 -4.2 0 -4 -4.5 05/05/2005 08:20:00 15.1 1 17.2 12.2 15.1 1.1 17.2 12.2 0.4 0 0.4 0.4 16 3 15 305 66 0 66 0 -4.2 0 -4 -4.5 05/05/2005 08:30:00 14.5 1.7 17.2 10.3 14.5 1.7 17.6 10.3 0.4 0 0.4 0.4 19 5 5 305 66 0 66 0 -4.1 0.1 -3.3 -4.5 05/05/2005 08:40:00 14.1 1.2 16.8 11.1 14.1 1.3 16.8 10.3 0.4 0 0.4 0.4 16 4 18 305 67 0 66 0 -4.1 0 -3.8 -4.5 05/05/2005 08:50:00 15.4 1.1 17.9 12.2 15.4 1.1 18.3 12.6 0.4 0 0.4 0.4 14 4 13 305 67 0 67 0 -4.3 0 -4 -4.5 05/05/2005 09:00:00 15 1.1 17.6 12.2 15 1.1 17.6 12.2 0.4 0 0.4 0.4 15 4 14 305 67 0 67 0 -4.4 0 -4 -4.7 05/05/2005 09:10:00 15.2 1.2 17.6 11.5 15.1 1.3 17.9 11.1 0.4 0 0.4 0.4 16 4 14 305 67 0 67 0 -4.4 0 -4 -4.7 05/05/2005 09:20:00 14.3 1.1 16.8 11.8 14.3 1.2 16.8 11.1 0.4 0 0.4 0.4 15 5 10 305 68 0 68 0 -4.1 0 -3.8 -4.2 05/05/2005 09:30:00 15 1.4 17.9 11.1 14.8 1.5 17.9 11.5 0.4 0 0.4 0.4 16 4 18 305 69 0 69 0 -4.1 0.1 -3.8 -4.5 05/05/2005 09:40:00 15.3 1.2 17.9 11.8 15.2 1.3 18.3 11.5 0.4 0 0.4 0.4 14 4 14 305 69 0 69 0 -4.2 0 -3.8 -4.5 05/05/2005 09:50:00 14.8 1.2 17.2 11.1 14.7 1.2 17.2 11.5 0.4 0 0.4 0.4 17 5 16 305 69 0 69 0 -4.2 0 -4 -4.5 05/05/2005 10:00:00 15.2 1.1 17.2 12.2 15.1 1.2 17.6 11.8 0.4 0 0.4 0.4 14 5 25 305 70 0 70 0 -4.2 0 -4 -4.5 05/05/2005 10:10:00 15.4 1.3 17.9 11.8 15.4 1.5 19.1 11.5 0.4 0 0.4 0.4 15 5 21 305 70 0 70 0 -4.2 0 -4 -4.5 05/05/2005 10:20:00 15.4 1.3 17.9 11.5 15.3 1.3 17.9 11.5 0.4 0 0.4 0.4 15 4 12 305 71 0 71 0 -4.1 0 -3.8 -4.2 05/05/2005 10:30:00 16.4 1.3 18.7 12.6 16.2 1.3 19.5 12.2 0.4 0 0.4 0.4 13 4 11 305 71 0 72 0 -4.2 0 -4 -4.5 05/05/2005 10:40:00 16.9 1 19.5 13.7 16.6 1.2 19.1 13.3 0.4 0 0.4 0.4 11 3 16 305 72 0 72 0 -4.2 0 -4 -4.5 05/05/2005 10:50:00 16.9 1 18.7 14.1 16.6 1.1 18.7 13.3 0.4 0 0.4 0.4 13 4 13 305 72 0 72 0 -4.2 0 -4 -4.5 05/05/2005 11:00:00 17.1 1.6 20.6 13 17 1.7 20.2 13 0.4 0 0.4 0.4 14 4 13 305 72 0 72 0 -4.3 0 -4 -4.5 05/05/2005 11:10:00 16.7 1.4 19.1 12.2 16.6 1.5 20.2 12.2 0.4 0 0.4 0.4 13 4 8 305 72 0 72 0 -4.2 0 -4 -4.5 05/05/2005 11:20:00 17 1.4 20.6 12.2 16.9 1.5 19.9 11.8 0.4 0 0.4 0.4 15 4 23 305 73 0 73 0 -4.2 0 -3.8 -4.5 05/05/2005 11:30:00 16.3 1.5 19.9 11.8 16.3 1.5 19.5 11.8 0.4 0 0.4 0.4 13 4 18 305 73 0 73 0 -4.2 0.1 -3.8 -4.5 05/05/2005 11:40:00 16.4 1.3 19.1 13 16.2 1.5 19.1 11.8 0.4 0 0.4 0.4 13 4 7 305 73 0 73 0 -4.2 0 -4 -4.5 05/05/2005 11:50:00 16.6 1.2 19.1 13.3 16.5 1.3 19.5 12.2 0.4 0 0.4 0.4 15 5 11 305 73 0 74 0 -4.1 0 -3.8 -4.2 05/05/2005 12:00:00 16.7 1.3 19.9 13 16.4 1.3 19.1 13 0.4 0 0.4 0.4 14 4 13 305 74 0 74 0 -4 0 -3.8 -4.2 05/05/2005 12:10:00 16.6 1.5 20.6 12.6 16.6 1.6 21.4 13 0.4 0 0.4 0.4 15 4 16 305 74 0 74 0 -4 0 -3.8 -4.2 05/05/2005 12:20:00 16.9 1.3 20.2 13 16.7 1.4 20.2 12.6 0.4 0 0.4 0.4 13 4 14 305 75 0 75 0 -4 0 -3.8 -4.2 05/05/2005 12:30:00 16.9 1.5 19.9 13 16.7 1.5 19.9 13.3 0.4 0 0.4 0.4 12 4 18 305 76 0 76 0 -4 0 -3.8 -4.2 05/05/2005 12:40:00 16.7 1.6 20.2 12.2 16.5 1.7 20.2 12.2 0.4 0 0.4 0.4 13 5 12 305 77 0 77 0 -3.9 0 -3.6 -4 05/05/2005 12:50:00 16.6 1.3 19.9 13 16.4 1.3 19.5 12.6 0.4 0 0.4 0.4 11 5 14 305 77 0 77 0 -4 0 -3.8 -4.2 05/05/2005 13:00:00 16.1 1.7 20.2 12.6 15.8 1.7 19.5 11.8 0.4 0 0.4 0.4 11 5 8 305 78 0 78 0 -3.9 0 -3.6 -4 05/05/2005 13:10:00 15.6 1.5 19.9 12.2 15.5 1.5 19.9 11.8 0.4 0 0.4 0.4 13 5 8 305 79 0 79 0 -3.8 0 -3.6 -4 05/05/2005 13:20:00 16 1.7 19.5 12.6 15.8 1.9 19.5 11.8 0.4 0 0.4 0.4 12 5 10 305 80 0 80 0 -3.8 0 -3.6 -4 05/05/2005 13:30:00 16.5 1.5 19.5 12.2 16.5 1.5 19.9 13 0.4 0 0.4 0.4 11 4 22 305 80 0 80 0 -3.8 0 -3.6 -4 05/05/2005 13:40:00 16.4 1.3 19.1 13.3 16.5 1.3 19.9 13 0.4 0 0.4 0.4 13 4 12 305 81 0 81 0 -3.7 0 -3.6 -3.8 05/05/2005 13:50:00 16.7 1.2 19.1 13 16.6 1.2 19.9 13 0.4 0 0.4 0.4 12 4 8 305 81 0 81 0 -3.9 0 -3.8 -4 05/05/2005 14:00:00 16.4 1.3 19.5 12.2 16.2 1.4 19.5 12.2 0.4 0 0.4 0.4 10 4 10 305 81 0 82 0 -3.9 0 -3.8 -4 05/05/2005 14:10:00 15.6 1.5 18.3 11.1 15.4 1.5 18.3 11.1 0.4 0 0.4 0.4 12 4 9 305 82 0 82 0 -3.9 0 -3.8 -4 05/05/2005 14:20:00 16.5 1.1 19.5 13.3 16.3 1.2 19.1 12.6 0.4 0 0.4 0.4 12 3 21 305 82 0 82 0 -3.9 0 -3.8 -4 05/05/2005 14:30:00 16.5 1.3 19.1 11.5 16.3 1.4 19.5 11.5 0.4 0 0.4 0.4 11 5 11 305 82 0 82 0 -3.9 0 -3.8 -4 05/05/2005 14:40:00 17.3 1.4 20.2 13.7 17.1 1.5 20.2 13.3 0.4 0 0.4 0.4 14 4 13 305 83 0 84 0 -3.9 0 -3.8 -4 05/05/2005 14:50:00 16.5 1.2 19.9 13.3 16.4 1.2 19.9 13 0.4 0 0.4 0.4 14 4 19 305 83 0 83 0 -4.1 0 -3.8 -4.2 05/05/2005 15:00:00 17.2 1.5 20.2 12.6 16.9 1.6 20.2 12.6 0.4 0 0.4 0.4 13 5 7 305 83 0 83 0 -4.1 0.1 -3.8 -4.5 05/05/2005 15:10:00 17.2 1.5 20.2 12.6 17 1.6 19.9 12.6 0.4 0 0.4 0.4 15 4 11 305 82 0 83 0 -4.2 0.1 -3.8 -4.5 05/05/2005 15:20:00 16.9 1.3 19.9 12.6 16.8 1.4 19.9 13 0.4 0 0.4 0.4 15 5 11 305 82 0 82 0 -4.2 0 -4 -4.5 05/05/2005 15:30:00 17 1.1 19.9 14.1 16.8 1.2 19.9 13.3 0.4 0 0.4 0.4 13 4 13 305 82 0 82 0 -4.3 0 -4 -4.5 05/05/2005 15:40:00 17.2 1.5 20.2 13.3 16.9 1.6 20.6 12.6 0.4 0 0.4 0.4 13 4 18 305 82 0 82 0 -4.4 0 -4 -4.7 05/05/2005 15:50:00 16.9 1.3 19.9 13.3 16.6 1.4 19.9 13 0.4 0 0.4 0.4 13 5 10 305 81 0 82 0 -4.4 0 -4.2 -4.5 05/05/2005 16:00:00 17.7 1.5 20.6 14.1 17.7 1.6 21 12.6 0.4 0 0.4 0.4 14 4 13 305 81 0 81 0 -4.5 0 -4.2 -4.7 05/05/2005 16:10:00 16.8 1.9 20.2 12.6 16.6 2 20.6 11.5 0.4 0 0.4 0.4 14 4 11 305 81 0 81 0 -4.5 0.1 -4 -4.7 05/05/2005 16:20:00 16.7 1.3 19.9 13.3 16.5 1.5 20.6 12.2 0.4 0 0.4 0.4 14 5 18 305 81 0 81 0 -4.4 0 -4.2 -4.7 05/05/2005 16:30:00 16.1 1.3 19.1 12.2 15.9 1.3 19.5 12.6 0.4 0 0.4 0.4 13 5 10 305 81 0 81 0 -4.4 0 -4.2 -4.5 05/05/2005 16:40:00 16.8 1.5 21.4 13.7 16.6 1.5 20.6 12.6 0.4 0 0.4 0.4 13 4 11 305 81 0 81 0 -4.4 0 -4 -4.7 05/05/2005 16:50:00 16.7 1.5 20.2 13 16.5 1.5 20.6 12.6 0.4 0 0.4 0.4 15 4 16 305 81 0 81 0 -4.5 0 -4.2 -4.7 05/05/2005 17:00:00 16.9 1.3 20.6 13 16.6 1.5 19.5 12.2 0.4 0 0.4 0.4 15 5 17 305 81 0 81 0 -4.5 0 -4 -4.7 05/05/2005 17:10:00 17.6 1.7 21.8 13.3 17.4 1.7 21.8 13 0.4 0 0.4 0.4 16 4 11 305 81 0 81 0 -4.6 0 -4.5 -4.7 05/05/2005 17:20:00 16.3 1.5 20.2 12.6 16.2 1.7 20.2 12.2 0.4 0 0.4 0.4 15 4 18 305 81 0 81 0 -4.5 0 -4.2 -4.7 05/05/2005 17:30:00 17.4 1.3 20.2 13.3 17.2 1.3 20.2 13.3 0.4 0 0.4 0.4 14 5 17 305 81 0 81 0 -4.8 0 -4.2 -4.9 05/05/2005 17:40:00 16 1.6 20.2 11.5 15.8 1.7 19.9 11.1 0.4 0 0.4 0.4 16 5 10 305 81 0 81 0 -4.6 0.1 -3.8 -4.9 05/05/2005 17:50:00 15.6 1.3 18.3 12.2 15.6 1.3 18.3 11.8 0.4 0 0.4 0.4 12 5 12 305 81 0 81 0 -4.8 0.1 -4.2 -4.9 05/05/2005 18:00:00 16.6 1.4 19.5 11.8 16.5 1.4 19.1 12.6 0.4 0 0.4 0.4 9 4 7 305 81 0 81 0 -4.8 0 -4.5 -4.9 05/05/2005 18:10:00 15.6 1.7 19.1 11.8 15.5 1.7 19.1 11.1 0.4 0 0.4 0.4 9 4 7 305 81 0 81 0 -4.9 0.1 -4.5 -5.1 05/05/2005 18:20:00 16.3 1.5 19.1 12.6 16.3 1.4 19.5 12.6 0.4 0 0.4 0.4 7 5 6 305 80 0 80 0 -4.9 0 -4.7 -5.1 05/05/2005 18:30:00 16.7 1.3 19.5 13.3 16.6 1.4 19.5 13 0.4 0 0.4 0.4 7 5 9 305 80 0 80 0 -4.9 0 -4.7 -5.1 05/05/2005 18:40:00 16.7 1.6 20.2 13 16.6 1.6 20.6 12.2 0.4 0 0.4 0.4 7 6 5 305 80 0 80 0 -4.9 0 -4.5 -4.9 05/05/2005 18:50:00 16.8 1.7 20.2 11.8 16.8 1.8 20.2 11.8 0.4 0 0.4 0.4 4 4 1 305 80 0 80 0 -5 0 -4.7 -5.1 05/05/2005 19:00:00 17.6 1.3 21 14.5 17.5 1.3 21 14.1 0.4 0 0.4 0.4 3 5 3 305 80 0 80 0 -5 0 -4.7 -5.1 05/05/2005 19:10:00 17.6 1.6 21 11.5 17.5 1.7 20.6 12.2 0.4 0 0.4 0.4 6 4 6 305 80 0 80 0 -4.8 0 -4.5 -4.9 05/05/2005 19:20:00 16.5 1.4 19.1 13 16.3 1.4 19.5 11.8 0.4 0 0.4 0.4 7 5 3 305 80 0 80 0 -4.7 0 -4.5 -4.9 05/05/2005 19:30:00 17.2 1.5 20.6 12.2 17.1 1.6 20.6 11.5 0.4 0 0.4 0.4 5 5 358 305 80 0 80 0 -4.7 0 -4.5 -4.9 05/05/2005 19:40:00 17.5 1.4 20.6 13 17.4 1.5 21 13.3 0.4 0 0.7 0.4 7 4 2 305 80 0 80 0 -4.7 0 -4.5 -4.9 05/05/2005 19:50:00 16.2 1.5 19.9 12.2 16.2 1.6 19.5 11.5 0.4 0 0.4 0.4 5 4 3 305 80 0 80 0 -4.6 0 -4.5 -4.7 05/05/2005 20:00:00 15.8 1.5 19.1 11.8 15.7 1.6 19.5 10.7 0.4 0 0.4 0.4 3 5 5 305 80 0 80 0 -4.6 0 -4.5 -4.7 05/05/2005 20:10:00 16.1 1 18.3 12.6 16 1.1 19.1 12.6 0.4 0 0.4 0.4 5 5 9 305 80 0 80 0 -4.6 0 -4.5 -4.7 05/05/2005 20:20:00 14.8 1.3 18.3 11.5 14.8 1.4 18.3 11.1 0.4 0 0.4 0.4 358 8 12 305 80 0 80 0 -4.7 0.2 -4.5 -5.1 05/05/2005 20:30:00 14.2 1.3 17.2 10.3 14.2 1.5 17.6 10.3 0.4 0 0.4 0.4 357 5 349 305 80 0 80 0 -4.7 0.1 -4.5 -4.9 05/05/2005 20:40:00 15.3 2 19.1 11.1 15.3 2 19.5 11.5 0.4 0 0.4 0.4 359 5 5 305 80 0 80 0 -4.7 0 -4.2 -4.7 05/05/2005 20:50:00 15.9 1.2 18.3 13 15.8 1.3 18.7 12.6 0.4 0 0.4 0.4 3 5 359 305 80 0 80 0 -4.7 0 -4.5 -4.7 05/05/2005 21:00:00 16 1.1 18.7 13.3 16 1.2 18.7 13 0.4 0 0.4 0.4 2 5 5 305 80 0 80 0 -4.6 0 -4.5 -4.7 05/05/2005 21:10:00 15 1.3 18.3 11.1 15 1.3 17.6 11.8 0.4 0 0.4 0.4 5 5 6 305 80 0 80 0 -4.5 0 -4.2 -4.7 05/05/2005 21:20:00 15.3 1.3 17.9 11.5 15.2 1.3 17.9 11.8 0.4 0 0.4 0.4 2 6 354 305 80 0 80 0 -4.4 0 -4 -4.7 05/05/2005 21:30:00 15.2 1.7 19.1 11.5 15.2 1.8 19.5 11.1 0.4 0 0.4 0.4 0 5 355 305 80 0 80 0 -4.4 0 -4.2 -4.7 05/05/2005 21:40:00 13.9 1 15.6 11.1 13.9 1.1 16.1 10.7 0.4 0 0.4 0.4 350 4 352 305 80 0 80 0 -4.9 0.1 -4.5 -4.9 05/05/2005 21:50:00 14 1.1 16.8 10.7 14 1.2 16.8 11.5 0.4 0 0.4 0.4 351 3 347 305 80 0 80 0 -4.9 0 -4.7 -4.9 05/05/2005 22:00:00 13.8 1.3 16.8 10.7 13.9 1.5 17.6 10.3 0.4 0 0.4 0.4 352 4 355 305 79 0 79 0 -4.8 0 -4.5 -5.1 05/05/2005 22:10:00 14.4 1 17.2 11.1 14.6 1.3 17.2 10.3 0.4 0 0.4 0.4 351 4 348 305 79 0 79 0 -4.9 0 -4.7 -5.1 05/05/2005 22:20:00 14.5 1 16.4 10.7 14.7 1 16.8 11.5 0.4 0 0.4 0.4 348 4 352 305 79 0 79 0 -5 0 -4.7 -5.1 05/05/2005 22:30:00 14.4 1.1 16.4 11.1 14.5 1.2 16.8 11.1 0.4 0 0.4 0.4 349 5 348 305 79 0 79 0 -5 0 -4.9 -5.1 05/05/2005 22:40:00 14.4 1.5 16.8 9.1 14.5 1.6 17.6 9.9 0.4 0 0.4 0.4 350 4 346 305 79 0 79 0 -5 0 -4.7 -5.1 05/05/2005 22:50:00 14.7 1.3 18.3 11.1 14.8 1.4 17.9 11.5 0.4 0 0.4 0.4 351 4 347 305 79 0 79 0 -5 0 -4.7 -5.1 05/05/2005 23:00:00 14.8 1 17.2 11.8 15.1 1.1 17.6 11.5 0.4 0 0.4 0.4 351 3 349 305 78 0 78 0 -5 0 -4.9 -5.1 05/05/2005 23:10:00 14.5 1.1 16.4 11.1 14.6 1.2 17.2 11.1 0.4 0 0.4 0.4 351 4 351 305 78 0 78 0 -5 0 -4.7 -5.1 05/05/2005 23:20:00 14.2 1.2 16.8 9.9 14.3 1.3 17.2 9.9 0.4 0 0.4 0.4 349 4 351 305 78 0 78 0 -5 0 -4.7 -5.1 05/05/2005 23:30:00 14.8 1 16.4 11.5 15 1 16.8 12.2 0.4 0 0.4 0.4 348 4 355 305 78 0 78 0 -5.1 0 -4.9 -5.1 05/05/2005 23:40:00 13.4 1.2 15.6 10.3 13.7 1.3 16.4 9.9 0.4 0 0.4 0.4 349 5 350 305 78 0 78 0 -5 0 -4.7 -5.1 05/05/2005 23:50:00 13.4 1 15.6 10.7 13.6 1.1 16.1 11.1 0.4 0 0.4 0.4 349 5 346 305 78 0 78 0 -4.9 0 -4.7 -5.1 05/06/2005 00:00:00 13.8 1 16.1 10.3 14 1 16.8 10.7 0.4 0 0.4 0.4 346 4 347 305 78 0 78 0 -5 0 -4.7 -5.1 05/06/2005 00:10:00 13.1 1 15.6 10.3 13.3 1.1 15.6 10.3 0.4 0 0.4 0.4 348 4 345 305 78 0 78 0 -4.9 0 -4.7 -5.1 05/06/2005 00:20:00 13.6 0.9 15.6 11.5 13.8 1 15.6 11.1 0.4 0 0.4 0.4 349 4 348 305 78 0 78 0 -4.9 0 -4.7 -4.9 05/06/2005 00:30:00 13.1 1 15.6 10.3 13.3 1.1 15.6 9.9 0.4 0 0.4 0.4 347 4 349 305 79 0 79 0 -4.9 0 -4.5 -4.9 05/06/2005 00:40:00 13.1 1 15.3 10.3 13.3 1.1 16.1 9.5 0.4 0 0.4 0.4 346 4 345 305 79 0 79 0 -4.9 0 -4.7 -5.1 05/06/2005 00:50:00 13.1 1.1 16.1 9.9 13.3 1.2 16.1 9.5 0.4 0 0.4 0.4 347 3 347 305 79 0 79 0 -4.9 0 -4.7 -4.9 05/06/2005 01:00:00 12.9 1 14.9 9.5 13.1 1 15.3 9.5 0.4 0 0.4 0.4 345 4 338 305 79 0 79 0 -4.9 0 -4.7 -4.9 05/06/2005 01:10:00 12.8 1.2 14.9 9.5 12.9 1.3 15.3 9.5 0.4 0 0.4 0.4 345 4 347 305 79 0 79 0 -4.9 0 -4.7 -4.9 05/06/2005 01:20:00 12.5 0.7 14.1 9.1 12.9 0.7 14.5 10.3 0.4 0 0.4 0.4 345 4 344 305 79 0 79 0 -4.8 0 -4.7 -5.1 05/06/2005 01:30:00 12.1 1 14.1 9.1 12.3 1 14.5 9.1 0.4 0 0.4 0.4 342 4 339 305 79 0 79 0 -4.7 0 -4.5 -4.9 05/06/2005 01:40:00 11.8 1 13.7 8.8 12 1 14.1 9.1 0.4 0 0.4 0.4 341 5 346 305 79 0 79 0 -4.7 0 -4.2 -4.9 05/06/2005 01:50:00 11.4 1 13.7 8.8 11.6 1 14.1 8.4 0.4 0 0.4 0.4 343 5 344 305 79 0 79 0 -4.6 0 -4.5 -4.7 05/06/2005 02:00:00 11.7 0.9 14.1 9.5 11.9 1 14.1 9.1 0.4 0 0.4 0.4 341 4 337 305 79 0 79 0 -4.6 0 -4.5 -4.7 05/06/2005 02:10:00 12.2 0.8 13.7 10.3 12.4 0.9 14.1 9.9 0.4 0 0.4 0.4 342 4 344 305 79 0 80 0 -4.6 0 -4 -4.7 05/06/2005 02:20:00 11.7 0.9 13.7 9.1 12 1 14.1 9.1 0.4 0 0.4 0.4 338 4 331 305 80 0 79 0 -4.6 0 -4.5 -4.7 05/06/2005 02:30:00 11.5 1 13.3 7.6 11.7 1.1 13.7 8.4 0.4 0 0.4 0.4 337 4 338 305 80 0 80 0 -4.7 0 -4.5 -4.7 05/06/2005 02:40:00 11.2 0.8 12.6 8.4 11.3 0.9 13 8.4 0.4 0 0.4 0.4 334 4 334 305 80 0 80 0 -4.7 0 -4.5 -4.7 05/06/2005 02:50:00 11.3 0.8 13.7 8.4 11.5 0.9 13.7 9.1 0.4 0 0.4 0.4 334 4 335 305 80 0 80 0 -4.7 0 -4.5 -4.7 05/06/2005 03:00:00 10.7 1 12.6 8 11 1.1 13 8 0.4 0 0.4 0.4 335 5 336 305 80 0 80 0 -4.6 0 -4.5 -4.7 05/06/2005 03:10:00 11.2 0.7 12.6 9.1 11.5 0.8 13 9.1 0.4 0 0.4 0.4 335 3 332 305 80 0 80 0 -4.7 0 -4.5 -4.9 05/06/2005 03:20:00 11 0.6 12.6 8.8 11.1 0.7 13 9.1 0.4 0 0.4 0.4 331 4 337 305 80 0 80 0 -4.7 0 -4.5 -4.7 05/06/2005 03:30:00 10.7 0.9 13 8.4 10.9 1 13 8.4 0.4 0 0.4 0.4 330 4 331 305 80 0 80 0 -4.7 0 -4.5 -4.7 05/06/2005 03:40:00 10.6 0.6 12.2 9.1 10.7 0.8 12.6 8.8 0.4 0 0.4 0.4 330 5 324 305 80 0 80 0 -4.6 0 -4.5 -4.7 05/06/2005 03:50:00 10.5 0.6 11.8 8.4 10.6 0.6 12.2 9.1 0.4 0 0.4 0.4 328 5 330 305 80 0 80 0 -4.7 0 -4.5 -4.7 05/06/2005 04:00:00 9.8 0.8 11.5 7.2 9.9 0.8 11.8 7.6 0.4 0 0.4 0.4 329 5 327 305 80 0 80 0 -4.6 0 -4.5 -4.7 05/06/2005 04:10:00 9.7 0.7 11.5 7.6 9.9 0.8 11.8 7.6 0.4 0 0.4 0.4 329 5 329 305 80 0 80 0 -4.6 0 -4.5 -4.7 05/06/2005 04:20:00 9.7 0.6 11.1 7.6 9.8 0.7 11.1 7.6 0.4 0 0.4 0.4 326 5 328 305 80 0 80 0 -4.5 0 -4.5 -4.7 05/06/2005 04:30:00 9.4 0.8 11.1 7.2 9.4 0.8 11.1 7.6 0.4 0 0.4 0.4 328 6 320 305 80 0 80 0 -4.5 0 -4.5 -4.7 05/06/2005 04:40:00 9.7 0.7 11.1 7.6 9.7 0.7 11.1 7.6 0.4 0 0.4 0.4 327 3 323 305 80 0 80 0 -4.4 0 -4.5 -4.7 05/06/2005 04:50:00 9.2 0.6 10.7 7.2 9.2 0.7 10.7 7.6 0.4 0 0.4 0.4 326 4 323 305 80 0 80 0 -4.4 0 -4 -4.7 05/06/2005 05:00:00 9.4 0.6 10.7 7.6 9.5 0.7 11.1 6.8 0.4 0 0.4 0.4 323 4 326 305 81 0 81 0 -4.4 0 -4.2 -4.5 05/06/2005 05:10:00 9.1 0.5 10.3 7.2 9.1 0.6 10.3 7.2 0.4 0 0.4 0.4 319 4 318 305 81 0 81 0 -4.4 0 -3.8 -4.5 05/06/2005 05:20:00 9.1 0.6 10.3 7.2 9.1 0.6 10.3 7.2 0.4 0 0.4 0.4 322 3 320 305 81 0 81 0 -4.3 0 -3.8 -4.5 05/06/2005 05:30:00 8 0.5 9.5 6.8 8.1 0.5 9.1 6.5 0.4 0 0.4 0.4 323 4 319 305 81 0 81 0 -4.2 0 -4 -4.5 05/06/2005 05:40:00 7.7 0.5 8.8 6.1 7.7 0.6 9.1 5.7 0.4 0 0.4 0.4 312 2 323 305 81 0 81 0 -4.2 0 -4 -4.5 05/06/2005 05:50:00 7.9 0.6 9.1 5.7 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 311 0 311 305 81 0 81 0 -4.2 0 -4 -4.2 05/06/2005 06:00:00 8.2 0.6 9.5 6.5 8.1 0.6 9.5 6.1 0.4 0 0.4 0.4 311 0 311 305 81 0 81 0 -4.2 0 -4 -4.5 05/06/2005 06:10:00 8.2 0.5 9.5 6.8 8.1 0.5 9.5 6.8 0.4 0 0.4 0.4 311 0 311 305 81 0 81 0 -4.2 0 -4 -4.5 05/06/2005 06:20:00 7.9 0.6 9.5 6.5 7.8 0.7 9.1 6.1 0.4 0 0.4 0.4 311 0 311 305 81 0 81 0 -4.2 0 -4 -4.5 05/06/2005 06:30:00 8.1 0.5 9.1 6.5 8 0.5 9.1 6.8 0.4 0 0.4 0.4 311 0 311 305 81 0 81 0 -4.1 0 -4 -4.2 05/06/2005 06:40:00 7.1 0.6 8.8 5.3 7.1 0.6 8.4 5.3 0.4 0 0.4 0.4 311 0 311 305 81 0 82 0 -4.1 0 -4 -4.2 05/06/2005 06:50:00 6.6 0.4 7.6 5.3 6.6 0.4 7.6 5.3 0.4 0 0.4 0.4 311 0 311 305 81 0 82 0 -4 0 -3.8 -4.2 05/06/2005 07:00:00 5.6 0.7 7.6 3.8 5.4 0.8 7.6 3.8 0.4 0 0.4 0.4 311 0 311 305 82 0 82 0 -4 0 -3.8 -4 05/06/2005 07:10:00 5.1 0.5 6.5 3.4 5.1 0.5 6.1 3.8 0.4 0 0.4 0.4 311 0 311 305 82 0 82 0 -3.9 0 -3.8 -4 05/06/2005 07:20:00 4.7 0.6 6.5 3.4 4.6 0.6 6.5 3.4 0.4 0 0.4 0.4 311 0 311 305 82 0 82 0 -3.9 0 -3.8 -4 05/06/2005 07:30:00 5 0.5 6.1 3.4 4.8 0.5 6.1 3.4 0.4 0 0.4 0.4 311 0 311 305 82 0 82 0 -3.9 0 -3.8 -4 05/06/2005 07:40:00 3.5 0.5 4.9 2.3 3.2 0.6 4.9 1.9 0.4 0 0.4 0.4 311 0 311 305 83 0 83 0 -3.9 0 -3.8 -4 05/06/2005 07:50:00 4 0.4 4.9 3 3.9 0.4 4.9 3 0.4 0 0.4 0.4 311 0 311 305 83 0 83 0 -3.8 0 -3.6 -3.8 05/06/2005 08:00:00 4.2 0.5 5.3 2.6 4.2 0.5 5.3 2.6 0.4 0 0.4 0.4 311 0 311 305 83 0 83 0 -3.8 0 -3.6 -3.8 05/06/2005 08:10:00 3.4 0.5 4.6 2.3 3.3 0.5 4.2 2.3 0.4 0 0.4 0.4 311 0 311 305 83 0 84 0 -3.7 0 -3.6 -3.8 05/06/2005 08:20:00 3.4 0.4 4.2 2.6 3.4 0.4 4.6 2.6 0.4 0 0.4 0.4 311 0 311 305 84 0 84 0 -3.7 0 -3.6 -3.8 05/06/2005 08:30:00 2.9 0.6 4.2 1.9 2.7 0.5 3.8 1.9 0.4 0 0.4 0.4 311 0 311 305 84 0 84 0 -3.5 0 -3.3 -3.8 05/06/2005 08:40:00 2.6 0.4 3.4 1.5 2.5 0.4 3.4 1.5 0.4 0 0.4 0.4 311 0 311 305 84 0 85 0 -3.5 0 -2.9 -3.8 05/06/2005 08:50:00 2.8 0.5 4.9 1.9 2.6 0.5 4.9 1.5 0.4 0 0.4 0.4 311 0 311 305 85 0 85 0 -3.4 0 -3.3 -3.6 05/06/2005 09:00:00 3.9 0.4 4.9 3 3.9 0.4 4.9 3 0.4 0 0.4 0.4 311 0 311 305 86 0 86 0 -3.3 0 -3.1 -3.3 05/06/2005 09:10:00 4.2 0.4 4.9 3 4.3 0.4 5.3 3.4 0.4 0 0.4 0.4 311 0 311 305 86 0 86 0 -3.2 0 -2.7 -3.3 05/06/2005 09:20:00 3.3 0.5 4.6 1.9 3.5 0.5 4.6 2.3 0.4 0 0.4 0.4 311 0 311 305 87 0 87 0 -3.3 0 -2.7 -3.3 05/06/2005 09:30:00 2.7 0.4 3.4 1.9 3 0.4 3.8 2.3 0.4 0 0.4 0.4 311 0 311 305 88 0 87 0 -3.2 0 -3.1 -3.3 05/06/2005 09:40:00 2.5 0.3 3 1.5 2.8 0.3 3.4 1.9 0.4 0 0.4 0.4 311 0 311 305 88 0 88 0 -3.1 0 -2.7 -3.1 05/06/2005 09:50:00 2 0.5 3 0.7 2.3 0.4 3 1.5 0.4 0 0.4 0.4 311 0 311 305 89 0 89 0 -2.9 0 -2.7 -3.1 05/06/2005 10:00:00 1 0.4 1.9 0.4 1.4 0.3 2.3 0.7 0.4 0 0.4 0.4 311 0 311 305 90 0 90 0 -2.8 0 -2.2 -2.9 05/06/2005 10:10:00 1.2 0.4 1.9 0.4 1.3 0.4 1.9 0.4 0.4 0 0.4 0.4 311 0 311 305 91 0 91 0 -2.7 0 -2.4 -2.7 05/06/2005 10:20:00 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 311 0 311 305 92 0 93 0 -2.8 0 -2.7 -2.9 05/06/2005 10:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 311 0 305 305 94 0 93 0 -2.7 0.1 -2.4 -2.7 05/06/2005 10:40:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 311 0 311 305 95 0 94 0 -2.6 0 -2.2 -2.7 05/06/2005 10:50:00 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 0.4 0 0.4 0.4 311 0 311 305 96 0 95 0 -2.7 0 -2.4 -2.7 05/06/2005 11:00:00 0.4 0.1 0.7 0.4 0.5 0.4 1.9 0.4 0.4 0 0.4 0.4 311 0 311 305 96 0 96 0 -2.7 0.1 -2.2 -2.9 05/06/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 311 0 305 305 97 0 97 0 -2.2 0.1 -1.8 -2.4 05/06/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 311 0 305 305 98 0 0 0 -2.2 0 -2 -2.4 05/06/2005 11:30:00 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 311 0 305 305 99 0 99 0 -2.2 0 -2 -2.2 05/06/2005 11:40:00 0.7 0.4 1.5 0.4 1.2 0.6 2.3 0.4 0.4 0 0.4 0.4 311 0 311 305 100 0 100 0 -2.4 0 -2 -2.7 05/06/2005 11:50:00 0.9 0.6 2.3 0.4 1.5 0.7 3 0.4 0.4 0 0.4 0.4 311 0 311 305 101 0 101 0 -2.4 0 -2.2 -2.7 05/06/2005 12:00:00 1.2 0.5 2.6 0.4 1.7 0.5 2.6 0.7 0.4 0 0.4 0.4 311 0 311 305 102 0 101 0 -2.6 0 -2.4 -2.7 05/06/2005 12:10:00 1.9 0.6 3.4 0.4 2.4 0.5 3.4 1.1 0.4 0 0.4 0.4 311 0 311 305 102 0 102 0 -2.4 0 -2.2 -2.7 05/06/2005 12:20:00 1.5 0.6 2.6 0.4 2.1 0.6 3.4 0.7 0.4 0 0.4 0.4 311 0 311 305 102 0 103 0 -2.3 0 -2.2 -2.4 05/06/2005 12:30:00 1.9 0.6 3 0.7 2.4 0.5 3.8 1.5 0.4 0 0.4 0.4 311 0 311 305 103 0 103 0 -2.4 0 -2.2 -2.7 05/06/2005 12:40:00 0.8 0.5 1.9 0.4 1.5 0.5 2.6 0.4 0.4 0 0.4 0.4 311 0 311 305 103 0 103 0 -2.2 0 -2 -2.4 05/06/2005 12:50:00 1.4 0.5 2.6 0.4 2.1 0.4 3 1.5 0.4 0 0.4 0.4 311 0 311 305 103 0 103 0 -2.2 0 -2 -2.4 05/06/2005 13:00:00 1.3 0.5 2.6 0.4 1.9 0.4 3 1.1 0.4 0 0.4 0.4 311 0 311 305 103 0 103 0 -2 0 -2 -2.2 05/06/2005 13:10:00 2 1 4.2 0.4 2.4 0.8 4.2 0.7 0.4 0 0.4 0.4 311 0 311 305 103 0 103 0 4 11.3 28.8 -2.2 05/06/2005 13:20:00 0.9 0.5 1.9 0.4 1.4 0.5 2.3 0.4 0.4 0 0.4 0.4 310 0 311 305 104 0 103 0 -1.8 0 -1.3 -2 05/06/2005 13:30:00 1.2 0.5 2.3 0.4 1.6 0.4 2.3 0.4 0.4 0 0.4 0.4 227 23 197 305 106 0 104 0 -1.8 0 -1.3 -2 05/06/2005 13:40:00 0.6 0.5 2.3 0.4 1.1 0.5 2.6 0.4 0.4 0 0.4 0.4 224 13 239 305 107 1 107 0 -1.6 0 -1.1 -1.8 05/06/2005 13:50:00 0.9 0.5 2.3 0.4 1.6 0.5 2.6 0.4 0.4 0 0.4 0.4 202 19 194 305 109 4 107 0 -1.6 0 -1.1 -1.8 05/06/2005 14:00:00 1.5 0.6 3 0.4 2.1 0.5 3.4 0.7 0.4 0 0.4 0.4 196 14 208 305 117 4 115 0 -1.7 0 -1.1 -1.8 05/06/2005 14:10:00 2.2 0.9 3.8 0.4 2.6 0.9 4.2 0.4 0.4 0.1 0.7 0.4 188 11 190 305 114 1 115 0 -1.6 0 -1.1 -1.8 05/06/2005 14:20:00 0.4 0.1 1.1 0.4 0.8 0.4 2.3 0.4 0.6 0.2 0.7 0.4 194 20 183 305 113 2 115 0 -1.1 0.2 -0.4 -1.8 05/06/2005 14:30:00 0.8 0.6 3 0.4 1.5 0.6 3 0.4 0.6 0.2 1.1 0.4 189 20 144 305 109 2 107 0 -0.9 0.1 -0.4 -1.1 05/06/2005 14:40:00 1.9 0.6 3.8 0.4 2.3 0.5 3.4 1.1 0.5 0.4 2.3 0.4 137 9 143 305 110 3 108 0 -0.4 0.1 0.3 -0.6 05/06/2005 14:50:00 1.4 0.6 3 0.4 2 0.4 3.4 1.1 0.4 0 0.4 0.4 137 15 155 305 117 1 118 0 -0.3 0.1 0.3 -0.4 05/06/2005 15:00:00 1.8 0.6 3 0.4 2.3 0.5 3 1.1 0.4 0 0.4 0.4 126 9 125 305 118 1 119 0 0 0.1 0.6 -0.4 05/06/2005 15:10:00 2.1 0.5 3.4 1.1 2.5 0.4 3.4 1.5 0.4 0 0.4 0.4 136 9 128 305 109 2 108 0 -0.2 0.1 0.6 -0.4 05/06/2005 15:20:00 2.4 0.6 3.4 0.7 2.8 0.5 3.8 1.1 0.4 0 0.4 0.4 136 11 128 305 109 1 111 0 -0.3 0 0.1 -0.6 05/06/2005 15:30:00 2.3 0.7 3.8 0.4 2.8 0.4 4.2 1.5 0.4 0 0.4 0.4 144 16 135 305 116 3 117 0 -0.4 0.1 0.1 -0.6 05/06/2005 15:40:00 2.4 0.9 4.2 0.4 2.9 0.6 4.2 1.5 0.4 0 0.4 0.4 150 18 136 305 119 0 119 0 -0.5 0 0.1 -0.6 05/06/2005 15:50:00 3.5 0.5 4.6 1.9 3.6 0.5 4.6 2.3 0.4 0 0.4 0.4 140 6 133 305 117 1 119 0 -0.7 0 -0.1 -0.8 05/06/2005 16:00:00 3.6 0.5 4.6 2.3 3.6 0.4 4.6 2.3 0.4 0 0.4 0.4 130 6 129 305 112 1 115 0 -0.7 0 -0.1 -1.1 05/06/2005 16:10:00 3.1 0.6 4.9 1.5 3.3 0.5 4.6 1.5 0.4 0 0.4 0.4 143 12 144 305 112 1 111 0 -0.7 0.1 -0.1 -1.1 05/06/2005 16:20:00 2.9 0.6 4.2 1.1 3 0.5 3.8 1.9 0.4 0 0.4 0.4 135 7 147 305 115 1 114 0 -0.8 0 -0.4 -1.1 05/06/2005 16:30:00 3.5 0.7 4.9 1.5 3.5 0.6 4.9 2.3 0.4 0 0.4 0.4 147 8 146 305 117 0 117 0 -0.8 0.1 -0.1 -1.1 05/06/2005 16:40:00 3.8 0.6 5.3 2.6 3.8 0.5 5.7 2.6 0.4 0 0.4 0.4 142 8 145 305 117 0 117 0 -0.8 0 -0.4 -1.1 05/06/2005 16:50:00 4 0.5 5.3 2.3 4 0.5 5.3 2.6 0.4 0 0.4 0.4 143 9 138 305 107 3 107 0 -1.1 0 -0.6 -1.3 05/06/2005 17:00:00 3.6 0.5 4.9 1.9 3.7 0.4 4.9 2.6 0.4 0 0.4 0.4 148 6 147 305 106 1 108 0 -1.1 0 -0.6 -1.3 05/06/2005 17:10:00 3.5 0.6 4.9 1.9 3.6 0.5 4.9 2.6 0.4 0 0.4 0.4 142 7 149 305 105 0 105 0 -1.1 0.1 -0.6 -1.3 05/06/2005 17:20:00 4 0.5 4.9 2.6 4.1 0.5 4.9 2.6 0.4 0 0.4 0.4 138 5 137 305 101 2 105 0 -1.1 0 -0.6 -1.3 05/06/2005 17:30:00 3.9 0.4 4.9 2.3 4 0.4 4.9 2.6 0.4 0 0.4 0.4 138 2 140 305 94 2 97 0 -1.3 0 -0.6 -1.3 05/06/2005 17:40:00 4.2 0.5 5.3 2.6 4.2 0.5 5.3 3 0.4 0 0.4 0.4 134 3 131 305 90 1 89 0 -1.1 0 -0.6 -1.3 05/06/2005 17:50:00 4 0.5 5.3 3 4 0.4 5.3 3 0.4 0 0.4 0.4 135 3 139 305 89 0 88 0 -1.2 0 -0.6 -1.3 05/06/2005 18:00:00 4.4 0.5 5.7 3 4.3 0.5 5.3 3 0.4 0 0.4 0.4 139 7 131 305 87 0 88 0 -1.3 0 -0.6 -1.5 05/06/2005 18:10:00 4.9 0.5 6.5 3.4 5 0.5 6.5 3.4 0.4 0 0.4 0.4 137 5 127 305 86 0 86 0 -1.5 0 -1.1 -1.5 05/06/2005 18:20:00 4.5 0.6 6.1 1.9 4.6 0.5 5.7 3 0.4 0 0.4 0.4 140 8 152 305 87 0 87 0 -1.5 0 -0.8 -1.8 05/06/2005 18:30:00 4.1 0.6 5.7 2.6 4.1 0.6 5.3 2.6 0.4 0 0.4 0.4 141 9 153 305 88 0 88 0 -1.5 0 -1.1 -1.8 05/06/2005 18:40:00 4.6 0.5 5.7 3 4.7 0.5 5.7 3.4 0.4 0 0.4 0.4 137 6 134 305 88 0 88 0 -1.5 0 -1.3 -1.8 05/06/2005 18:50:00 4.5 0.7 6.1 2.6 4.5 0.6 6.1 3 0.4 0 0.4 0.4 141 7 132 305 88 0 88 0 -1.6 0 -1.3 -1.8 05/06/2005 19:00:00 4.7 0.9 7.2 2.6 4.7 0.8 7.6 2.6 0.4 0 0.4 0.4 138 8 147 305 87 0 87 0 -1.6 0 -1.3 -1.8 05/06/2005 19:10:00 4.4 0.9 6.5 2.3 4.4 0.8 6.5 3 0.4 0 0.4 0.4 142 9 133 305 86 0 87 0 -1.7 0 -1.3 -1.8 05/06/2005 19:20:00 4 1.1 6.5 1.1 4.2 0.9 6.1 1.9 0.4 0 0.4 0.4 147 9 150 305 85 0 86 0 -1.8 0 -1.3 -2 05/06/2005 19:30:00 2.6 1.2 6.5 0.4 3.1 0.9 5.7 1.1 0.4 0 0.4 0.4 144 16 135 305 86 0 86 0 -1.7 0 -1.3 -1.8 05/06/2005 19:40:00 3.8 0.7 5.7 2.3 4.1 0.7 5.7 2.6 0.4 0 0.4 0.4 137 11 142 305 86 0 86 0 -1.7 0 -1.3 -1.8 05/06/2005 19:50:00 2.4 1.1 4.9 0.4 2.9 0.8 4.9 0.7 0.4 0 0.4 0.4 158 22 144 305 86 0 86 0 -1.8 0 -1.8 -2 05/06/2005 20:00:00 1.2 0.8 2.6 0.4 2 0.6 3.4 0.4 0.4 0 0.4 0.4 186 13 194 305 88 0 88 0 -2.2 0 -1.8 -2.4 05/06/2005 20:10:00 1.9 0.5 3 0.7 2.5 0.4 3.4 1.5 0.4 0 0.4 0.4 191 5 184 305 89 0 89 0 -2.2 0 -2 -2.4 05/06/2005 20:20:00 1.6 0.7 3 0.4 2.3 0.5 3.4 1.1 0.4 0 0.4 0.4 196 9 210 305 90 0 91 0 -2.3 0 -2.2 -2.4 05/06/2005 20:30:00 1.9 0.6 3 0.4 2.5 0.5 3.4 1.1 0.4 0 0.4 0.4 197 6 198 305 91 0 91 0 -2.3 0 -2.2 -2.4 05/06/2005 20:40:00 1.2 0.6 2.6 0.4 2.1 0.5 3 1.1 0.4 0 0.4 0.4 187 7 190 305 91 0 91 0 -2.3 0 -2.2 -2.4 05/06/2005 20:50:00 2 0.6 3 0.4 2.7 0.4 3.4 1.5 0.4 0 0.4 0.4 187 5 188 305 91 0 92 0 -2.3 0 -2.2 -2.4 05/06/2005 21:00:00 1.1 0.5 2.6 0.4 2.1 0.4 3 1.1 0.4 0 0.4 0.4 187 7 192 305 90 0 90 0 -2.4 0 -2.4 -2.7 05/06/2005 21:10:00 1.2 0.7 2.6 0.4 2 0.5 3 0.7 0.4 0 0.4 0.4 172 18 151 305 90 0 90 0 -2.4 0 -2.2 -2.7 05/06/2005 21:20:00 2 0.6 3 0.4 2.8 0.4 3.4 1.9 0.4 0 0.4 0.4 184 5 186 305 90 0 90 0 -2.4 0 -2.2 -2.7 05/06/2005 21:30:00 1.7 0.5 3.8 0.7 2.3 0.4 3.4 1.1 0.4 0 0.4 0.4 190 10 197 305 89 0 90 0 -2.6 0 -2.4 -2.7 05/06/2005 21:40:00 1.5 0.7 3.4 0.4 2.2 0.6 4.2 1.1 0.4 0 0.4 0.4 189 9 184 305 89 0 89 0 -2.6 0 -2.4 -2.7 05/06/2005 21:50:00 1.6 0.7 2.6 0.4 2.4 0.5 3.4 1.1 0.4 0 0.4 0.4 194 5 197 305 89 0 89 0 -2.6 0 -2.4 -2.7 05/06/2005 22:00:00 1.3 0.6 2.6 0.4 2.1 0.4 3 1.1 0.4 0 0.4 0.4 197 3 199 305 89 0 89 0 -2.7 0 -2.7 -2.7 05/06/2005 22:10:00 1.4 0.5 2.3 0.4 2 0.3 3 1.1 0.4 0 0.4 0.4 204 2 205 305 89 0 88 0 -2.7 0 -2.7 -2.7 05/06/2005 22:20:00 1.6 0.5 2.6 0.4 2.3 0.4 3.4 0.7 0.4 0 0.4 0.4 194 9 194 305 89 0 89 0 -2.8 0 -2.7 -2.7 05/06/2005 22:30:00 1.7 0.8 3.4 0.4 2.3 0.5 3.4 0.4 0.4 0 0.4 0.4 168 23 142 305 88 0 89 0 -2.8 0 -2.7 -2.9 05/06/2005 22:40:00 1.2 0.7 3 0.4 2.1 0.6 3.4 0.7 0.4 0 0.4 0.4 154 12 163 305 88 0 88 0 -2.7 0 -2.4 -2.7 05/06/2005 22:50:00 1.8 0.8 3.8 0.4 2.6 0.8 4.2 0.4 0.4 0 0.4 0.4 161 11 162 305 88 0 88 0 -2.7 0 -2.4 -2.7 05/06/2005 23:00:00 2.5 0.8 4.6 0.4 3.3 0.6 5.3 1.5 0.4 0 0.4 0.4 160 19 117 305 88 0 87 0 -2.7 0 -2.4 -2.7 05/06/2005 23:10:00 1.7 0.7 3.4 0.4 2.4 0.6 3.8 1.1 0.4 0 0.4 0.4 140 9 131 305 87 0 87 0 -2.8 0 -2.2 -2.7 05/06/2005 23:20:00 1.8 0.7 3.8 0.4 2.6 0.5 3.8 1.5 0.4 0 0.4 0.4 153 13 154 305 88 0 87 0 -2.8 0 -2.7 -2.7 05/06/2005 23:30:00 2.3 0.6 3.4 0.4 3.1 0.4 4.2 2.3 0.4 0 0.4 0.4 185 10 187 305 88 0 88 0 -2.8 0 -2.7 -3.1 05/06/2005 23:40:00 2.3 0.4 3.4 0.7 3.1 0.4 4.2 1.9 0.4 0 0.4 0.4 185 8 194 305 88 0 87 0 -3 0 -2.7 -3.1 05/06/2005 23:50:00 1.3 0.8 3.4 0.4 2.3 0.7 4.6 1.1 0.4 0 0.4 0.4 173 12 196 305 88 0 87 0 -3 0 -2.9 -3.1 05/07/2005 00:00:00 1.4 1.1 4.6 0.4 2.4 0.9 5.3 1.1 0.4 0 0.4 0.4 170 13 144 305 88 0 88 0 -2.9 0 -2.7 -3.1 05/07/2005 00:10:00 2.1 0.8 4.2 0.4 2.9 0.6 4.2 1.5 0.4 0 0.4 0.4 172 22 137 305 88 0 87 0 -2.8 0 -2.7 -3.1 05/07/2005 00:20:00 1 0.5 2.6 0.4 1.8 0.4 2.6 0.4 0.4 0 0.4 0.4 184 17 142 305 88 0 88 0 -2.9 0 -2.7 -3.1 05/07/2005 00:30:00 2.8 1 4.6 0.4 3.3 0.7 4.9 1.1 0.4 0 0.4 0.4 151 15 157 305 88 0 88 0 -2.9 0 -2.7 -3.1 05/07/2005 00:40:00 3.6 0.9 5.3 1.1 3.8 0.9 5.7 2.3 0.4 0 0.4 0.4 144 8 141 305 88 0 88 0 -2.8 0 -2.4 -3.1 05/07/2005 00:50:00 2.9 0.8 4.6 1.1 3.2 0.7 4.9 1.5 0.4 0 0.4 0.4 117 5 113 305 88 0 88 0 -2.8 0 -2.7 -2.9 05/07/2005 01:00:00 2.3 0.8 4.6 0.4 2.8 0.6 4.9 1.5 0.4 0 0.4 0.4 138 22 114 305 89 0 88 0 -2.8 0 -2.7 -2.9 05/07/2005 01:10:00 1.2 0.9 4.2 0.4 2.1 0.7 4.2 1.1 0.4 0 0.4 0.4 160 13 155 305 89 0 90 0 -2.8 0 -2.7 -3.1 05/07/2005 01:20:00 1.9 1.2 4.6 0.4 2.6 1 4.9 0.7 0.4 0 0.4 0.4 156 9 158 305 89 0 89 0 -2.8 0 -2.4 -3.1 05/07/2005 01:30:00 1.4 0.7 3 0.4 2.1 0.5 3.4 1.1 0.4 0 0.4 0.4 145 12 141 305 89 0 90 0 -2.8 0 -2.7 -3.1 05/07/2005 01:40:00 1.5 0.7 4.2 0.4 2.3 0.5 3 0.7 0.4 0 0.4 0.4 139 20 148 305 90 0 90 0 -2.8 0 -2.7 -3.1 05/07/2005 01:50:00 1.9 0.7 3.8 0.7 2.6 0.5 4.2 1.5 0.4 0 0.4 0.4 149 13 151 305 90 0 90 0 -2.8 0 -2.7 -3.1 05/07/2005 02:00:00 3.1 0.6 4.6 1.1 3.4 0.5 4.6 1.9 0.4 0 0.4 0.4 127 13 133 305 90 0 90 0 -2.8 0 -2.7 -3.1 05/07/2005 02:10:00 2.4 0.8 4.2 0.4 2.9 0.7 4.6 1.5 0.4 0 0.4 0.4 142 6 153 305 90 0 90 0 -3 0 -2.7 -3.1 05/07/2005 02:20:00 1.2 0.7 3 0.4 1.9 0.5 3.4 0.7 0.4 0 0.4 0.4 131 16 142 305 90 0 90 0 -3 0 -2.9 -3.1 05/07/2005 02:30:00 1.8 0.7 3.4 0.4 2.5 0.5 3.8 1.5 0.4 0 0.4 0.4 137 22 152 305 90 0 91 0 -3 0 -2.4 -3.1 05/07/2005 02:40:00 1.6 0.8 3.4 0.4 2.1 0.5 3.4 0.7 0.4 0 0.4 0.4 105 0 105 305 90 0 90 0 -2.9 0 -2.7 -3.1 05/07/2005 02:50:00 1.8 0.6 3.4 0.4 2.2 0.5 3.4 1.1 0.4 0 0.4 0.4 86 15 65 305 90 0 90 0 -2.9 0 -2.4 -3.1 05/07/2005 03:00:00 1.6 0.6 3 0.4 2.1 0.5 3 0.7 0.4 0 0.4 0.4 67 11 67 305 90 0 90 0 -2.9 0 -2.7 -3.1 05/07/2005 03:10:00 1.5 0.8 3 0.4 2 0.6 3.4 0.4 0.4 0 0.4 0.4 78 17 87 305 91 0 91 0 -2.9 0 -2.7 -3.1 05/07/2005 03:20:00 2.2 0.4 3.4 1.1 2.6 0.4 3.8 1.9 0.4 0 0.4 0.4 85 10 106 305 91 0 91 0 -3 0 -2.7 -3.1 05/07/2005 03:30:00 1.3 1 3.4 0.4 1.9 0.8 3.8 0.4 0.4 0 0.4 0.4 100 18 105 305 91 0 91 0 -3 0 -2.9 -3.1 05/07/2005 03:40:00 0.4 0.2 1.1 0.4 0.9 0.5 2.3 0.4 0.4 0 0.4 0.4 96 10 87 305 91 0 91 0 -3.1 0 -2.7 -3.1 05/07/2005 03:50:00 2.5 0.8 4.2 0.4 2.8 0.6 4.2 1.5 0.4 0 0.4 0.4 80 11 67 305 91 0 91 0 -3 0 -2.9 -3.1 05/07/2005 04:00:00 3 0.6 4.6 1.5 3.2 0.5 4.6 1.9 0.4 0 0.4 0.4 79 8 83 305 91 0 91 0 -3 0 -2.9 -3.1 05/07/2005 04:10:00 2.6 0.7 4.6 0.7 2.9 0.5 4.2 1.9 0.4 0 0.4 0.4 91 10 93 305 91 0 91 0 -3 0 -2.9 -3.1 05/07/2005 04:20:00 3.1 0.7 4.9 1.5 3.4 0.6 4.6 1.9 0.4 0 0.4 0.4 100 12 85 305 91 0 91 0 -3.1 0 -2.9 -3.1 05/07/2005 04:30:00 3 0.7 5.7 1.5 3.2 0.6 4.9 1.9 0.4 0 0.4 0.4 82 15 78 305 91 0 91 0 -3.1 0 -2.7 -3.3 05/07/2005 04:40:00 2.3 0.6 4.2 0.7 2.7 0.5 4.2 1.5 0.4 0 0.4 0.4 80 8 66 305 90 0 90 0 -3.1 0 -3.1 -3.3 05/07/2005 04:50:00 3.5 1.1 5.3 1.1 3.7 1 5.7 1.5 0.4 0 0.4 0.4 67 8 59 305 90 0 90 0 -3 0 -2.9 -3.1 05/07/2005 05:00:00 3.7 0.9 5.3 1.9 3.7 0.8 5.3 2.3 0.4 0 0.4 0.4 70 8 67 305 91 0 91 0 -3 0 -2.9 -3.1 05/07/2005 05:10:00 3.9 1 6.5 1.9 4 0.9 6.8 1.9 0.4 0 0.4 0.4 59 11 68 305 91 0 91 0 -2.9 0 -2.7 -3.1 05/07/2005 05:20:00 3.3 0.5 4.6 1.9 3.6 0.4 4.9 2.3 0.4 0 0.4 0.4 56 7 57 305 91 0 91 0 -2.8 0 -2.7 -3.1 05/07/2005 05:30:00 3.5 0.6 4.6 2.3 3.8 0.5 4.9 2.6 0.4 0 0.4 0.4 59 7 48 305 91 0 91 0 -2.8 0 -2.7 -3.1 05/07/2005 05:40:00 3.7 0.4 4.6 2.6 4.1 0.4 4.9 3 0.4 0 0.4 0.4 48 5 60 305 92 0 92 0 -2.8 0 -2.7 -3.1 05/07/2005 05:50:00 4 0.4 4.9 2.6 4.2 0.4 4.9 3.4 0.4 0 0.4 0.4 61 5 62 305 92 0 92 0 -2.8 0 -2.7 -3.1 05/07/2005 06:00:00 3.6 0.4 4.6 2.3 3.7 0.4 4.6 2.6 0.4 0 0.4 0.4 67 6 61 305 92 0 92 0 -2.8 0 -2.7 -3.1 05/07/2005 06:10:00 3.8 0.4 4.6 2.3 3.9 0.4 4.6 2.6 0.4 0 0.4 0.4 66 6 64 305 93 0 92 0 -2.8 0 -2.7 -3.1 05/07/2005 06:20:00 3.8 0.5 4.6 2.3 3.9 0.4 4.9 2.6 0.4 0 0.4 0.4 64 6 70 305 93 0 93 0 -2.8 0 -2.7 -3.1 05/07/2005 06:30:00 4.2 0.3 5.3 3.4 4.3 0.3 4.9 3.4 0.4 0 0.4 0.4 64 4 63 305 93 0 93 0 -2.9 0 -2.7 -3.1 05/07/2005 06:40:00 3.6 0.4 4.6 2.6 3.8 0.5 4.9 2.6 0.4 0 0.4 0.4 68 5 57 305 93 0 93 0 -3 0 -2.7 -3.1 05/07/2005 06:50:00 2.9 0.5 4.2 1.5 3 0.4 3.8 1.9 0.4 0 0.4 0.4 78 5 73 305 94 0 94 0 -2.9 0 -2.7 -3.1 05/07/2005 07:00:00 3.1 0.6 4.2 1.5 3.3 0.6 4.6 1.9 0.4 0 0.4 0.4 61 11 54 305 94 0 94 0 -2.8 0 -2.7 -3.1 05/07/2005 07:10:00 3.4 0.4 4.6 2.3 3.4 0.4 4.2 2.3 0.4 0 0.4 0.4 80 5 71 305 95 0 95 0 -2.8 0 -2.7 -2.9 05/07/2005 07:20:00 3.3 0.4 4.2 2.3 3.4 0.4 4.6 2.3 0.4 0 0.4 0.4 73 6 85 305 95 0 95 0 -2.8 0 -2.7 -2.7 05/07/2005 07:30:00 3.9 0.5 4.9 2.3 3.9 0.5 4.9 2.6 0.4 0 0.4 0.4 71 5 72 305 96 0 96 0 -2.7 0 -2.7 -2.7 05/07/2005 07:40:00 4 0.6 5.3 2.6 4.1 0.6 5.3 2.6 0.4 0 0.4 0.4 56 11 48 305 96 0 96 0 -2.7 0 -2.4 -2.7 05/07/2005 07:50:00 4.3 0.5 5.3 3 4.4 0.5 5.3 3.4 0.4 0 0.4 0.4 56 5 51 305 96 0 96 0 -2.7 0 -2.4 -2.7 05/07/2005 08:00:00 3.3 0.4 4.2 2.3 3.4 0.4 4.6 2.3 0.4 0 0.4 0.4 58 6 52 305 97 0 97 0 -2.6 0 -2.4 -2.7 05/07/2005 08:10:00 3.5 0.3 4.6 2.6 3.7 0.3 4.6 3 0.4 0 0.4 0.4 52 5 46 305 98 0 98 0 -2.6 0 -2.4 -2.7 05/07/2005 08:20:00 4 0.3 4.9 3.4 4.2 0.3 4.9 3.4 0.4 0 0.4 0.4 52 4 57 305 98 0 98 0 -2.6 0 -2.4 -2.7 05/07/2005 08:30:00 3.6 0.4 4.2 2.3 3.8 0.4 4.6 2.6 0.4 0 0.4 0.4 58 5 52 305 98 0 98 0 -2.5 0 -2.2 -2.7 05/07/2005 08:40:00 3.5 0.4 4.2 2.6 3.7 0.4 4.6 2.6 0.4 0 0.4 0.4 57 4 55 305 99 0 99 0 -2.4 0 -2.2 -2.7 05/07/2005 08:50:00 3.1 0.3 3.8 2.3 3.4 0.3 4.2 2.6 0.4 0 0.4 0.4 59 6 61 305 101 0 101 0 -2.4 0 -2 -2.7 05/07/2005 09:00:00 2.8 0.4 3.8 1.9 3.2 0.4 4.2 1.9 0.4 0 0.4 0.4 60 4 61 305 102 0 101 0 -2.4 0 -2.2 -2.7 05/07/2005 09:10:00 2.1 0.2 2.6 1.5 2.7 0.2 3.4 2.3 0.4 0 0.4 0.4 57 6 52 305 103 1 103 0 -2.6 0.1 -2.2 -2.7 05/07/2005 09:20:00 2 0.3 2.6 1.1 2.6 0.2 3 1.9 0.4 0 0.4 0.4 52 7 48 305 105 1 104 0 -2.6 0 -2.2 -2.7 05/07/2005 09:30:00 1.8 0.4 2.6 0.7 2.5 0.3 3.4 1.9 0.4 0 0.4 0.4 47 6 42 305 108 1 106 0 -2.7 0 -2.2 -2.7 05/07/2005 09:40:00 1.6 0.3 2.3 0.7 2.3 0.3 3 1.9 0.4 0 0.4 0.4 47 4 58 305 112 1 111 0 -2.4 0 -2 -2.7 05/07/2005 09:50:00 2 0.2 2.6 1.1 2.6 0.2 3 1.9 0.4 0 0.4 0.4 45 5 52 305 116 0 115 0 -2.6 0 -2.2 -2.7 05/07/2005 10:00:00 1.9 0.3 2.6 1.1 2.5 0.2 3 1.9 0.4 0 0.4 0.4 46 6 48 305 117 0 117 0 -2.6 0 -2.4 -2.7 05/07/2005 10:10:00 2 0.2 2.6 1.1 2.5 0.2 3 1.9 0.4 0 0.4 0.4 50 5 58 305 118 0 117 0 -2.6 0 -2.4 -2.7 05/07/2005 10:20:00 1.7 0.3 2.6 0.7 2.3 0.3 3 1.5 0.4 0 0.4 0.4 38 5 41 305 119 1 120 0 -2.6 0 -2.4 -2.7 05/07/2005 10:30:00 1.6 0.3 2.3 0.7 2.2 0.2 2.6 1.5 0.4 0 0.4 0.4 40 6 29 305 121 0 120 0 -2.4 0 -2.2 -2.7 05/07/2005 10:40:00 2.2 0.4 3 1.1 2.7 0.3 3.4 1.5 0.4 0 0.4 0.4 46 5 53 305 121 1 121 0 -2.3 0 -2 -2.7 05/07/2005 10:50:00 2.2 0.3 3 1.5 2.6 0.3 3.4 1.9 0.4 0 0.4 0.4 40 6 39 305 119 0 120 0 -2.4 0 -2.2 -2.7 05/07/2005 11:00:00 2.4 0.3 3 1.5 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 42 4 39 305 121 1 120 0 -2.4 0 -2.2 -2.7 05/07/2005 11:10:00 2.8 0.2 3.4 2.3 3 0.3 3.8 2.3 0.4 0 0.4 0.4 50 4 52 305 121 0 120 0 -2.5 0 -2.4 -2.7 05/07/2005 11:20:00 2.4 0.3 3 1.5 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 50 6 55 305 119 0 120 0 -2.4 0 -2.2 -2.4 05/07/2005 11:30:00 2.1 0.3 3 1.5 2.4 0.3 3 1.5 0.4 0 0.4 0.4 49 7 53 305 121 1 120 0 -2.2 0 -2 -2.4 05/07/2005 11:40:00 1.2 0.5 2.3 0.4 1.6 0.5 2.6 0.4 0.4 0 0.4 0.4 59 7 59 305 124 1 123 0 -2 0 -1.8 -2.4 05/07/2005 11:50:00 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 20 24 48 305 127 1 126 0 -1.6 0.1 -1.3 -2 05/07/2005 12:00:00 0.5 0.3 1.5 0.4 1.1 0.4 1.9 0.4 0.4 0 0.4 0.4 345 9 340 305 129 0 128 0 -1.5 0 -1.3 -1.8 05/07/2005 12:10:00 0.4 0.2 1.1 0.4 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 332 15 340 305 127 2 125 0 -1.3 0 -1.1 -1.5 05/07/2005 12:20:00 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 341 6 305 305 121 2 123 0 -1.1 0.1 -0.6 -1.3 05/07/2005 12:30:00 1 0.7 3.4 0.4 1.5 0.6 3 0.4 0.4 0 0.4 0.4 276 72 23 305 121 2 119 0 -0.8 0.2 -0.1 -1.3 05/07/2005 12:40:00 0.4 0.2 1.1 0.4 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 345 19 355 305 125 2 122 0 -1.2 0.1 -0.6 -1.5 05/07/2005 12:50:00 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 339 6 332 305 128 0 128 0 -1 0.1 -0.4 -1.1 05/07/2005 13:00:00 0.5 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 13 8 27 305 129 0 129 0 -1.1 0 -0.6 -1.3 05/07/2005 13:10:00 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 27 12 27 305 128 1 127 0 -1.2 0 -0.8 -1.3 05/07/2005 13:20:00 0.5 0.4 2.3 0.4 0.8 0.5 2.6 0.4 0.4 0 0.4 0.4 8 64 31 305 126 3 126 0 -1 0.2 -0.1 -1.3 05/07/2005 13:30:00 0.8 0.5 1.9 0.4 1.1 0.6 2.3 0.4 0.4 0 0.7 0.4 264 79 232 305 127 2 129 0 -0.7 0.2 0.1 -1.1 05/07/2005 13:40:00 2.4 0.4 3.4 1.1 2.3 0.4 3.4 1.1 0.4 0 0.4 0.4 251 9 230 305 127 0 127 0 -1.2 0.1 -0.6 -1.3 05/07/2005 13:50:00 2.3 0.5 3.4 0.7 2.5 0.4 3.4 1.5 0.4 0 0.4 0.4 242 9 238 305 128 1 128 0 -1.3 0.1 -0.6 -1.5 05/07/2005 14:00:00 2.3 0.4 3.4 1.1 2.4 0.5 3.4 1.1 0.4 0 0.4 0.4 253 8 243 305 131 1 129 0 -1.1 0 -0.6 -1.3 05/07/2005 14:10:00 2.2 0.5 3.4 0.7 2.3 0.4 3.4 1.5 0.4 0 0.4 0.4 252 11 257 305 134 1 133 0 -1.1 0.1 -0.6 -1.3 05/07/2005 14:20:00 2.7 0.5 3.8 1.5 2.6 0.5 3.8 1.5 0.4 0 0.4 0.4 258 8 258 305 135 0 135 0 -1.1 0.1 -0.4 -1.3 05/07/2005 14:30:00 2.7 0.4 3.8 1.5 2.5 0.5 3.4 1.5 0.4 0 0.4 0.4 261 9 247 305 133 1 134 0 -0.9 0.1 -0.4 -1.1 05/07/2005 14:40:00 2.6 0.5 3.8 0.7 2.7 0.5 3.8 1.1 0.4 0 0.4 0.4 253 8 255 305 131 0 132 0 -1 0.1 -0.4 -1.3 05/07/2005 14:50:00 2.7 0.5 4.2 1.1 2.5 0.4 3.4 1.5 0.4 0 0.4 0.4 259 8 259 305 132 0 132 0 -0.9 0.1 -0.4 -1.1 05/07/2005 15:00:00 3 0.3 3.8 1.9 3 0.4 3.8 2.3 0.4 0 0.4 0.4 248 7 253 305 131 0 132 0 -0.9 0.2 -0.4 -1.1 05/07/2005 15:10:00 3.3 0.4 4.2 1.9 3.2 0.5 4.6 1.9 0.4 0 0.4 0.4 257 8 254 305 130 0 130 0 -0.7 0.2 0.1 -1.1 05/07/2005 15:20:00 3.6 0.5 4.6 1.1 3.4 0.6 4.6 1.9 0.4 0 0.4 0.4 257 8 259 305 130 0 130 0 -0.3 0.2 0.3 -0.6 05/07/2005 15:30:00 3.6 0.6 4.9 1.5 3.4 0.6 4.9 2.3 0.4 0 0.4 0.4 255 11 236 305 129 0 130 0 -0.6 0.1 0.1 -0.8 05/07/2005 15:40:00 3.8 0.7 4.9 1.9 3.4 0.7 4.9 1.9 0.4 0 0.4 0.4 259 9 261 305 128 0 128 0 -0.6 0 0.1 -0.8 05/07/2005 15:50:00 3.6 0.6 4.9 1.9 3.4 0.6 4.9 1.9 0.4 0 0.4 0.4 256 15 250 305 127 0 127 0 -1 0.1 -0.4 -1.3 05/07/2005 16:00:00 3.2 0.5 4.6 1.9 2.9 0.5 4.6 1.9 0.4 0 0.4 0.4 249 13 235 305 127 0 128 0 -0.5 0.1 0.1 -1.1 05/07/2005 16:10:00 3.6 0.5 4.6 2.6 3.5 0.5 5.3 2.3 0.4 0 0.4 0.4 243 9 245 305 128 0 128 0 -0.7 0.1 -0.1 -1.1 05/07/2005 16:20:00 3.5 0.6 5.3 1.5 3.3 0.6 4.9 1.9 0.4 0 0.4 0.4 251 10 258 305 128 0 127 0 -0.5 0.2 0.1 -0.8 05/07/2005 16:30:00 4 0.6 5.7 2.3 3.8 0.7 5.3 1.9 0.4 0 0.4 0.4 252 9 258 305 128 0 128 0 -0.6 0.2 0.1 -1.1 05/07/2005 16:40:00 3.2 0.7 5.3 1.5 2.8 0.6 4.2 1.5 0.4 0 0.4 0.4 262 8 266 305 128 0 129 0 -0.7 0 -0.4 -1.1 05/07/2005 16:50:00 3.5 0.5 4.6 2.3 3.2 0.7 4.6 1.5 0.4 0 0.4 0.4 251 11 236 305 128 0 128 0 -0.7 0.2 -0.1 -1.1 05/07/2005 17:00:00 3.9 0.9 5.3 1.5 3.6 1 5.3 1.5 0.4 0 0.4 0.4 252 15 236 305 127 1 126 0 -0.8 0.2 -0.4 -1.1 05/07/2005 17:10:00 4 0.8 5.7 2.6 3.7 0.7 5.7 1.9 0.4 0 0.4 0.4 245 11 248 305 126 0 126 0 -0.9 0.2 -0.4 -1.1 05/07/2005 17:20:00 3.5 1 6.1 1.5 3.4 0.8 5.7 1.9 0.4 0 0.4 0.4 241 11 238 305 126 0 126 0 -1 0.2 -0.4 -1.1 05/07/2005 17:30:00 4.5 1 6.5 2.3 4.2 0.9 6.5 2.3 0.4 0 0.4 0.4 245 9 237 305 124 2 126 0 -1 0.2 -0.6 -1.3 05/07/2005 17:40:00 4.5 1.1 6.8 1.9 4.1 1.1 6.5 1.9 0.4 0 0.4 0.4 255 12 243 305 123 1 122 0 -1.1 0 -0.6 -1.3 05/07/2005 17:50:00 4.6 0.9 6.8 2.3 4.3 1 6.8 1.9 0.4 0 0.4 0.4 242 12 245 305 124 0 124 0 -1.2 0.1 -0.8 -1.8 05/07/2005 18:00:00 3.7 0.7 5.7 2.3 3.3 0.7 5.7 1.9 0.4 0 0.4 0.4 258 7 251 305 124 0 125 0 -1.4 0.1 -0.6 -1.8 05/07/2005 18:10:00 4.8 1 7.2 2.6 4.5 0.9 6.8 2.3 0.4 0 0.4 0.4 238 12 254 305 124 0 124 0 -1.4 0.2 -0.8 -1.5 05/07/2005 18:20:00 4.8 0.8 6.5 3 4.6 0.7 6.1 2.6 0.4 0 0.4 0.4 232 9 233 305 124 0 125 0 -1.5 0.1 -1.1 -1.8 05/07/2005 18:30:00 4.4 0.7 6.5 3 4.2 0.7 6.1 2.6 0.4 0 0.4 0.4 250 8 262 305 126 1 125 0 -1.6 0.1 -1.1 -1.8 05/07/2005 18:40:00 4.7 1 6.5 2.6 4.5 0.8 6.1 2.6 0.4 0 0.4 0.4 243 9 251 305 128 0 128 0 -1.7 0 -1.1 -2 05/07/2005 18:50:00 4.1 0.7 6.1 2.3 3.9 0.6 5.3 2.6 0.4 0 0.4 0.4 245 10 251 305 127 0 127 0 -1.8 0 -1.3 -2 05/07/2005 19:00:00 4.6 0.6 5.7 2.6 4.4 0.6 5.7 3 0.4 0 0.4 0.4 229 10 224 305 127 0 127 0 -1.8 0 -1.3 -2 05/07/2005 19:10:00 4.6 0.5 6.1 3.4 4.4 0.5 5.7 3 0.4 0 0.4 0.4 232 8 234 305 126 0 126 0 -1.9 0.1 -1.3 -2 05/07/2005 19:20:00 3.5 0.6 5.3 1.9 3.5 0.6 5.7 2.3 0.4 0 0.4 0.4 234 11 229 305 126 0 126 0 -1.8 0.1 -1.3 -2.2 05/07/2005 19:30:00 4.8 0.8 6.8 3 4.6 0.8 6.5 3 0.4 0 0.4 0.4 231 8 239 305 126 0 126 0 -1.9 0.1 -1.3 -2.2 05/07/2005 19:40:00 4.2 0.6 5.7 2.6 4.1 0.6 5.3 2.6 0.4 0 0.4 0.4 239 12 256 305 127 0 126 0 -2 0 -1.8 -2 05/07/2005 19:50:00 4.5 0.5 6.1 3.4 4.3 0.6 5.7 2.3 0.4 0 0.4 0.4 240 11 239 305 126 0 126 0 -2 0 -1.8 -2.2 05/07/2005 20:00:00 4 0.7 5.3 1.9 3.8 0.6 5.3 1.9 0.4 0 0.4 0.4 231 12 229 305 124 1 125 0 -2 0.1 -1.8 -2.2 05/07/2005 20:10:00 4.1 1 6.5 2.3 4 0.9 6.5 2.3 0.4 0 0.4 0.4 244 8 234 305 124 0 124 0 -2 0 -1.5 -2 05/07/2005 20:20:00 4.6 0.9 6.8 2.6 4.1 1 6.5 2.3 0.4 0 0.4 0.4 248 9 254 305 124 0 124 0 -1.9 0 -1.3 -2 05/07/2005 20:30:00 4.7 0.7 6.5 2.6 4 0.8 6.1 2.3 0.4 0 0.4 0.4 258 6 257 305 125 0 125 0 -1.9 0 -1.3 -2 05/07/2005 20:40:00 4.3 1 6.5 1.5 3.9 1.1 6.5 1.5 0.4 0 0.4 0.4 250 11 234 305 126 1 127 0 -1.8 0 -1.3 -2 05/07/2005 20:50:00 4.7 0.8 6.5 3 4.5 0.8 6.5 3 0.4 0 0.4 0.4 237 8 230 305 128 0 127 0 -1.9 0 -1.3 -2 05/07/2005 21:00:00 4.3 0.5 5.7 3.4 4.1 0.5 6.1 2.6 0.4 0 0.4 0.4 227 8 218 305 127 0 127 0 -1.9 0 -1.3 -2 05/07/2005 21:10:00 5 0.8 6.5 3 4.7 0.8 6.5 3 0.4 0 0.4 0.4 228 9 224 305 127 0 127 0 -2 0.1 -1.3 -2.2 05/07/2005 21:20:00 5.2 0.7 7.2 3.4 4.9 0.8 6.8 3 0.4 0 0.4 0.4 240 8 236 305 126 0 126 0 -2.1 0.1 -1.8 -2.4 05/07/2005 21:30:00 4.7 0.7 6.5 3 4.5 0.7 6.1 2.6 0.4 0 0.4 0.4 231 8 234 305 125 0 125 0 -2.2 0 -1.8 -2.4 05/07/2005 21:40:00 4.7 0.7 6.1 3 4.4 0.7 5.7 2.6 0.4 0 0.4 0.4 223 9 223 305 123 0 123 0 -2.1 0.1 -1.5 -2.2 05/07/2005 21:50:00 4.8 0.5 6.1 3.4 4.5 0.6 6.1 3 0.4 0 0.4 0.4 232 8 224 305 123 0 123 0 -2.2 0.1 -1.8 -2.4 05/07/2005 22:00:00 5.1 1 7.2 2.6 4.9 0.9 6.8 3 0.4 0 0.4 0.4 217 8 224 305 122 0 122 0 -2.2 0 -1.8 -2.4 05/07/2005 22:10:00 4.4 0.9 6.5 2.6 4.2 0.9 6.5 2.3 0.4 0 0.4 0.4 217 8 213 305 122 1 123 0 -2.2 0.1 -1.8 -2.4 05/07/2005 22:20:00 5 0.8 6.8 3.8 4.8 0.8 6.8 3.4 0.4 0 0.4 0.4 226 8 228 305 122 0 122 0 -2.3 0 -1.8 -2.4 05/07/2005 22:30:00 4.5 0.5 5.7 3.4 4.3 0.6 5.7 2.6 0.4 0 0.4 0.4 217 6 224 305 121 0 120 0 -2.2 0 -1.8 -2.4 05/07/2005 22:40:00 4.4 0.5 5.7 3 4.3 0.6 5.7 2.6 0.4 0 0.4 0.4 210 7 204 305 120 0 120 0 -2.2 0 -1.8 -2.4 05/07/2005 22:50:00 4.9 0.6 6.5 3 4.7 0.6 6.1 3 0.4 0 0.4 0.4 213 5 227 305 120 0 120 0 -2.1 0.1 -1.5 -2.4 05/07/2005 23:00:00 4.3 0.7 6.1 2.6 4.2 0.7 5.7 2.3 0.4 0 0.4 0.4 215 7 214 305 123 2 125 0 -2.2 0.1 -1.8 -2.4 05/07/2005 23:10:00 4.7 0.6 6.1 2.6 4.6 0.7 6.1 3 0.4 0 0.4 0.4 212 10 215 305 125 0 125 0 -2.2 0.1 -1.8 -2.4 05/07/2005 23:20:00 4.5 0.6 5.7 3 4.4 0.6 5.7 2.6 0.4 0 0.4 0.4 206 5 203 305 125 0 125 0 -2.3 0 -1.8 -2.4 05/07/2005 23:30:00 4.4 0.5 5.3 3 4.3 0.6 5.3 2.3 0.4 0 0.4 0.4 207 6 210 305 126 0 126 0 -2.2 0 -1.8 -2.4 05/07/2005 23:40:00 4.7 0.4 5.7 3.4 4.6 0.5 5.7 3 0.4 0 0.4 0.4 205 4 203 305 126 0 126 0 -2.1 0 -1.8 -2.2 05/07/2005 23:50:00 4.6 0.4 6.1 3 4.5 0.4 5.3 3 0.4 0 0.4 0.4 205 5 215 305 127 0 127 0 -2 0 -1.8 -2.2 05/08/2005 00:00:00 5 0.5 6.5 3.8 5 0.5 6.5 3.4 0.4 0 0.4 0.4 201 5 201 305 127 0 127 0 -2 0 -1.8 -2 05/08/2005 00:10:00 5.1 0.4 6.5 4.2 5 0.5 6.1 3.8 0.4 0 0.4 0.4 199 3 198 305 127 0 127 0 -2 0 -1.8 -2 05/08/2005 00:20:00 5.5 0.4 6.5 4.9 5.4 0.3 6.5 4.2 0.4 0 0.4 0.4 199 3 203 305 127 0 127 0 -2 0 -1.8 -2 05/08/2005 00:30:00 4.9 0.4 5.7 3.8 5 0.5 6.1 3.4 0.4 0 0.4 0.4 189 4 194 305 127 0 127 0 -1.9 0 -1.8 -2 05/08/2005 00:40:00 3.9 0.8 5.7 1.9 4.8 0.5 6.1 3.8 0.4 0 0.4 0.4 180 7 186 305 127 0 127 0 -1.8 0 -1.8 -2 05/08/2005 00:50:00 4.1 0.8 6.1 2.3 5.7 0.5 6.8 4.2 0.4 0 0.4 0.4 178 5 186 305 126 0 126 0 -1.8 0 -1.8 -2 05/08/2005 01:00:00 5.1 0.8 6.5 3 5.7 0.5 6.8 4.6 0.4 0 0.4 0.4 185 6 182 305 124 0 125 0 -1.9 0 -1.3 -2 05/08/2005 01:10:00 4.7 0.7 6.8 2.6 5.7 0.6 7.2 4.2 0.4 0 0.4 0.4 181 5 181 305 123 0 124 0 -1.9 0 -1.8 -2 05/08/2005 01:20:00 5 1 6.5 2.3 5.7 0.8 7.2 3.4 0.4 0 0.4 0.4 181 9 186 305 121 1 122 0 -1.9 0 -1.5 -2 05/08/2005 01:30:00 3.5 0.8 5.7 1.9 4.3 0.7 5.7 2.6 0.4 0 0.4 0.4 172 11 182 305 120 0 121 0 -2 0 -1.8 -2.2 05/08/2005 01:40:00 5 1.1 6.8 1.5 5.3 1 7.2 3.4 0.4 0 0.4 0.4 190 10 202 305 118 0 119 0 -1.5 0 -1.1 -1.8 05/08/2005 01:50:00 5.3 0.7 6.8 3.8 5.4 0.7 7.6 3.8 0.4 0 0.4 0.4 191 6 205 305 118 0 119 0 -1.6 0 -1.5 -1.8 05/08/2005 02:00:00 5.2 0.7 6.8 3 5.6 0.6 6.8 4.2 0.4 0 0.4 0.4 187 6 187 305 118 0 117 0 -1.5 0.1 -1.1 -1.8 05/08/2005 02:10:00 4.9 0.6 6.1 3 5.1 0.6 6.5 3.4 0.4 0 0.4 0.4 189 5 190 305 117 1 117 0 -1.5 0 -1.3 -1.8 05/08/2005 02:20:00 4.8 0.4 5.7 3.4 5 0.4 6.1 3.8 0.4 0 0.4 0.4 189 5 182 305 119 0 119 0 -1.6 0 -1.1 -1.8 05/08/2005 02:30:00 4.7 0.5 6.1 3.8 4.8 0.5 6.1 3.8 0.4 0 0.4 0.4 193 7 193 305 121 1 120 0 -1.4 0 -1.1 -1.5 05/08/2005 02:40:00 4.6 0.5 5.7 3 4.9 0.5 6.1 3 0.4 0 0.4 0.4 190 6 196 305 122 0 122 0 -1.2 0 -0.8 -1.3 05/08/2005 02:50:00 5 0.5 6.5 3.4 5.1 0.5 6.8 3.8 0.4 0 0.4 0.4 194 7 195 305 122 1 122 0 -1.1 0 -1.1 -1.3 05/08/2005 03:00:00 4.7 0.5 6.1 3.4 4.8 0.5 6.1 3.4 0.4 0 0.4 0.4 201 7 207 305 123 0 124 0 -1.2 0 -1.1 -1.3 05/08/2005 03:10:00 4.2 0.3 5.3 3.4 4.4 0.4 5.3 3.4 0.4 0 0.4 0.4 192 5 196 305 122 1 123 0 -1.2 0 -1.1 -1.3 05/08/2005 03:20:00 4.2 0.6 5.3 2.6 4.5 0.5 5.7 3.4 0.4 0 0.4 0.4 191 9 184 305 121 0 121 0 -1.1 0 -0.8 -1.3 05/08/2005 03:30:00 3.8 0.5 5.3 2.3 4 0.5 4.9 2.6 0.4 0 0.4 0.4 192 6 193 305 121 0 121 0 -1.1 0 -0.8 -1.3 05/08/2005 03:40:00 3.9 0.9 5.3 1.9 4 0.7 5.3 2.3 0.4 0 0.4 0.4 193 7 198 305 120 0 121 0 -1.1 0 -1.1 -1.3 05/08/2005 03:50:00 5.4 0.6 7.2 4.2 5.1 0.6 6.8 3.8 0.4 0 0.4 0.4 203 4 208 305 120 0 120 0 -1.1 0 -0.6 -1.3 05/08/2005 04:00:00 5.9 0.4 7.2 4.6 5.9 0.4 6.8 4.6 0.4 0 0.4 0.4 204 3 208 305 120 0 120 0 -1.1 0 -1.1 -1.3 05/08/2005 04:10:00 5.9 0.4 7.2 4.6 5.8 0.5 7.2 4.2 0.4 0 0.4 0.4 206 3 208 305 120 0 120 0 -1.1 0 -0.6 -1.1 05/08/2005 04:20:00 6.3 0.4 7.2 5.3 6.2 0.5 7.2 4.6 0.4 0 0.4 0.4 205 3 203 305 121 0 121 0 -1.1 0 -0.6 -1.1 05/08/2005 04:30:00 6.2 0.6 7.6 4.6 5.8 0.6 7.2 4.2 0.4 0 0.4 0.4 211 5 217 305 121 0 121 0 -1 0 -0.8 -1.1 05/08/2005 04:40:00 6.6 0.5 8 5.3 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 214 3 213 305 121 0 122 0 -1 0 -0.8 -1.1 05/08/2005 04:50:00 6.7 0.5 8.4 5.3 6.3 0.6 8 4.6 0.4 0 0.4 0.4 220 5 218 305 122 0 122 0 -0.9 0 -0.6 -1.1 05/08/2005 05:00:00 6.4 0.4 7.2 5.3 6 0.6 7.2 4.6 0.4 0 0.4 0.4 229 6 227 305 122 0 122 0 -0.9 0 -0.4 -1.1 05/08/2005 05:10:00 5.2 0.6 6.8 3.8 4.7 0.7 6.1 2.6 0.4 0 0.4 0.4 248 9 233 305 123 0 122 0 -1.1 0 -0.4 -1.3 05/08/2005 05:20:00 4.8 0.5 6.1 3 4 0.6 5.7 2.6 0.4 0 0.4 0.4 259 6 250 305 123 0 123 0 -1.1 0 -1.1 -1.3 05/08/2005 05:30:00 4.7 0.6 6.5 3.4 3.7 0.7 5.7 2.3 0.4 0 0.4 0.4 264 6 265 305 123 0 123 0 -1.2 0 -1.1 -1.3 05/08/2005 05:40:00 5.2 0.9 6.8 2.6 4.3 0.7 5.7 2.6 0.4 0 0.4 0.4 265 7 270 305 123 0 123 0 -1.2 0 -1.1 -1.3 05/08/2005 05:50:00 4.8 1 6.5 1.9 3.9 0.7 6.1 1.9 0.4 0 0.4 0.4 266 7 270 305 122 0 122 0 -1.2 0 -1.1 -1.3 05/08/2005 06:00:00 5.1 0.6 6.1 3.4 4.4 0.6 5.7 2.3 0.4 0 0.4 0.4 278 7 264 305 122 0 122 0 -1.3 0 -1.1 -1.5 05/08/2005 06:10:00 5.1 0.5 6.5 3.4 4.6 0.5 6.1 3 0.4 0 0.4 0.4 280 5 279 305 123 1 124 0 -1.4 0 -1.1 -1.5 05/08/2005 06:20:00 4.8 0.6 6.1 3 4.3 0.6 6.1 2.6 0.4 0 0.4 0.4 280 6 272 305 123 0 123 0 -1.5 0.1 -1.1 -1.8 05/08/2005 06:30:00 5.5 0.5 6.5 3.8 4.9 0.7 6.1 3 0.4 0 0.4 0.4 278 5 278 305 123 0 122 0 -1.6 0 -1.3 -1.8 05/08/2005 06:40:00 5.1 0.5 6.1 3.4 4.6 0.7 6.1 3 0.4 0 0.4 0.4 278 7 280 305 124 0 124 0 -1.6 0 -1.1 -1.8 05/08/2005 06:50:00 4.8 0.7 6.1 2.6 4 0.8 5.7 1.9 0.4 0 0.4 0.4 273 8 275 305 108 15 123 0 -1.7 0 -1.3 -2 05/08/2005 07:00:00 5.3 0.5 6.5 3 4.8 0.7 5.7 2.3 0.4 0 0.4 0.4 278 6 270 305 92 0 92 0 -1.9 0 -1.8 -2 05/08/2005 07:10:00 4.3 0.8 5.7 2.6 3.6 0.6 5.7 2.3 0.4 0 0.4 0.4 275 7 278 305 93 1 91 0 -2.1 0 -2 -2.2 05/08/2005 07:20:00 4.2 0.6 5.7 2.3 3.5 0.6 5.3 1.9 0.4 0 0.4 0.4 274 8 274 305 93 0 93 0 -2.2 0 -2 -2.4 05/08/2005 07:30:00 4.4 0.6 5.3 2.6 3.8 0.6 4.9 1.9 0.4 0 0.4 0.4 276 6 276 305 93 0 93 0 -2.2 0 -2 -2.4 05/08/2005 07:40:00 3.8 0.9 5.3 1.1 3.3 0.8 4.9 1.1 0.4 0 0.4 0.4 273 7 270 305 92 0 92 0 -2.2 0 -2 -2.4 05/08/2005 07:50:00 3.8 0.5 4.9 2.6 3.1 0.5 4.2 1.9 0.4 0 0.4 0.4 273 7 275 305 91 0 91 0 -2.2 0 -2 -2.4 05/08/2005 08:00:00 3.1 0.5 4.6 1.9 2.7 0.5 3.8 1.5 0.4 0 0.4 0.4 264 9 268 305 91 0 91 0 -2.2 0 -1.8 -2.4 05/08/2005 08:10:00 2.3 0.7 3.8 0.4 2.1 0.5 3.4 1.1 0.4 0 0.4 0.4 263 8 268 305 90 0 91 0 -2.2 0 -2 -2.4 05/08/2005 08:20:00 2.2 0.5 3.4 0.7 2.2 0.5 3.4 1.1 0.4 0 0.4 0.4 249 6 261 305 88 1 87 0 -2.3 0 -2.2 -2.4 05/08/2005 08:30:00 3.2 0.4 4.2 2.3 3 0.4 3.8 1.9 0.4 0 0.4 0.4 260 8 273 305 88 0 88 0 -2.1 0.1 -1.8 -2.4 05/08/2005 08:40:00 2.8 0.5 3.8 1.1 2.5 0.6 3.8 1.1 0.4 0 0.4 0.4 263 8 256 305 86 1 87 0 -1.9 0 -1.3 -2 05/08/2005 08:50:00 3.1 0.3 3.8 1.9 2.8 0.4 3.8 1.9 0.4 0 0.4 0.4 258 7 261 305 83 0 84 0 -1.9 0 -1.8 -2 05/08/2005 09:00:00 2.8 0.4 3.8 1.5 2.7 0.4 3.8 1.9 0.4 0 0.4 0.4 256 7 256 305 80 1 82 0 -1.8 0 -1.1 -2 05/08/2005 09:10:00 3 0.4 3.8 1.9 2.8 0.5 3.8 1.1 0.4 0 0.4 0.4 263 7 266 305 77 1 78 0 -1.7 0 -1.3 -2 05/08/2005 09:20:00 2.6 0.5 3.8 1.5 2.6 0.5 4.2 1.1 0.4 0 0.4 0.4 253 8 260 305 76 4 80 0 -1.7 0 -1.1 -2 05/08/2005 09:30:00 2.5 0.5 3.4 0.7 2.6 0.5 3.8 1.1 0.4 0 0.4 0.4 251 9 260 305 78 1 78 0 -1.6 0 -1.1 -2 05/08/2005 09:40:00 2.5 0.5 3.4 0.7 2.5 0.4 3.8 1.5 0.4 0 0.4 0.4 257 8 266 305 75 0 75 0 -1.5 0.1 -0.8 -1.8 05/08/2005 09:50:00 2.6 0.5 3.8 1.1 2.4 0.4 3.4 1.5 0.4 0 0.4 0.4 266 9 256 305 72 1 71 0 -1.4 0.1 -0.8 -1.8 05/08/2005 10:00:00 2.3 0.4 3 1.1 2.2 0.5 3.4 1.1 0.4 0 0.4 0.4 261 9 256 305 69 1 70 0 -1.4 0.1 -0.6 -1.5 05/08/2005 10:10:00 2.2 0.5 3 0.7 2.3 0.5 3.4 1.1 0.4 0 0.4 0.4 257 8 265 305 66 1 66 0 -1.2 0 -0.6 -1.3 05/08/2005 10:20:00 2.2 0.6 3.8 0.7 2.1 0.5 3.4 1.1 0.4 0 0.4 0.4 264 10 269 305 63 1 64 0 -1.2 0 -0.8 -1.3 05/08/2005 10:30:00 2.4 0.4 3.4 1.1 2.4 0.4 3.4 1.1 0.4 0 0.4 0.4 255 8 251 305 57 2 56 0 -1.2 0.2 -0.6 -1.5 05/08/2005 10:40:00 2.4 0.5 3.4 0.7 2.4 0.4 3.4 1.1 0.4 0 0.4 0.4 255 9 251 305 55 0 55 0 -1.1 0.2 -0.6 -1.5 05/08/2005 10:50:00 2.4 0.5 3.4 1.1 2.4 0.5 3.4 1.1 0.4 0 0.4 0.4 247 9 247 305 53 1 53 0 -1.1 0.1 -0.6 -1.3 05/08/2005 11:00:00 2.8 0.5 3.8 1.1 2.7 0.5 3.8 1.5 0.4 0 0.4 0.4 257 10 260 305 48 2 48 0 -1.1 0.1 -0.6 -1.3 05/08/2005 11:10:00 2.5 0.5 3.8 1.1 2.4 0.4 3.4 1.5 0.4 0 0.4 0.4 254 9 259 305 41 3 45 0 -1 0.1 -0.4 -1.1 05/08/2005 11:20:00 2.6 0.4 3.8 1.1 2.6 0.5 3.8 1.1 0.4 0 0.4 0.4 249 13 264 305 31 2 32 0 -1.1 0.1 -0.6 -1.3 05/08/2005 11:30:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.1 0.4 0 0.4 0.4 252 9 251 305 24 1 27 0 -1 0.1 -0.6 -1.1 05/08/2005 11:40:00 2.5 0.5 4.2 1.1 2.5 0.5 3.8 1.5 0.4 0 0.4 0.4 254 9 262 305 20 1 20 0 -0.9 0.1 -0.4 -1.3 05/08/2005 11:50:00 2.5 0.4 3.4 1.5 2.6 0.4 3.8 1.5 0.4 0 0.4 0.4 254 6 257 305 17 1 18 0 -0.9 0.2 -0.4 -1.1 05/08/2005 12:00:00 2.6 0.5 3.8 1.1 2.5 0.5 4.2 1.1 0.4 0 0.4 0.4 268 12 288 305 14 1 15 0 -0.5 0.2 0.3 -1.1 05/08/2005 12:10:00 2.6 0.5 3.8 0.7 2.4 0.4 3.4 1.1 0.4 0 0.4 0.4 274 8 281 305 11 1 13 0 -0.4 0.2 0.1 -0.6 05/08/2005 12:20:00 2.2 0.6 4.6 1.1 2.2 0.6 4.6 0.7 0.4 0 0.4 0.4 270 13 303 305 9 1 9 0 -0.3 0.2 0.3 -0.6 05/08/2005 12:30:00 2.2 0.5 3.4 0.4 2.1 0.4 3 1.1 0.4 0 0.4 0.4 262 12 279 305 7 1 7 0 -0.4 0.1 0.1 -0.6 05/08/2005 12:40:00 2.3 0.6 3.8 0.7 2.1 0.5 4.2 0.7 0.4 0 0.4 0.4 262 13 278 305 5 0 5 0 -0.3 0.2 0.1 -0.6 05/08/2005 12:50:00 1.7 0.7 3 0.4 1.8 0.6 3.4 0.4 0.4 0 0.4 0.4 268 16 278 305 4 0 4 0 0 0.2 0.6 -0.6 05/08/2005 13:00:00 2.5 0.5 3.8 1.1 2.3 0.5 3.8 1.5 0.4 0 0.4 0.4 266 13 268 305 2 0 2 0 -0.1 0.2 0.6 -0.4 05/08/2005 13:10:00 2.3 0.5 3.8 0.7 2.3 0.5 3.8 1.1 0.4 0 0.4 0.4 268 13 263 305 2 0 2 0 -0.1 0.2 0.6 -0.4 05/08/2005 13:20:00 2.3 0.6 3.4 0.4 2.3 0.6 3.4 0.7 0.4 0 0.4 0.4 257 17 241 305 1 0 1 0 -0.1 0.2 0.6 -0.6 05/08/2005 13:30:00 2 0.5 3.8 0.7 2.1 0.5 3.8 0.7 0.4 0 0.4 0.4 271 15 284 305 1 0 1 0 0.2 0.2 0.8 0.1 05/08/2005 13:40:00 2.2 0.6 3.4 0.4 2.3 0.6 3.8 1.1 0.4 0 0.4 0.4 267 15 287 305 0 0 0 0 0.3 0.2 0.8 0.1 05/08/2005 13:50:00 1.9 0.5 3 0.4 2 0.5 3 0.7 0.4 0 0.4 0.4 270 17 252 305 0 0 0 0 0.3 0.3 1 -0.1 05/08/2005 14:00:00 1.9 0.7 3.8 0.4 2.1 0.6 3.8 0.4 0.4 0 0.4 0.4 285 20 290 305 0 0 0 0 1 0.2 1.5 0.6 05/08/2005 14:10:00 1.6 0.6 3 0.4 1.7 0.6 3.8 0.4 0.4 0 0.4 0.4 264 13 259 305 0 0 0 0 0.4 0.3 1 -0.1 05/08/2005 14:20:00 1.6 0.8 4.2 0.4 1.7 0.7 4.6 0.4 0.4 0 0.4 0.4 286 29 318 305 0 0 0 0 0.6 0.3 1.3 -0.1 05/08/2005 14:30:00 2.3 0.5 3.8 1.1 2.6 0.5 3.8 1.5 0.4 0 0.4 0.4 324 10 316 305 0 0 0 0 0.9 0.2 1.5 0.3 05/08/2005 14:40:00 2.1 0.6 3.8 0.7 2.4 0.5 3.4 0.7 0.4 0 0.4 0.4 333 15 313 305 0 0 0 0 0.4 0 1 0.3 05/08/2005 14:50:00 2 0.5 3 0.7 2.4 0.4 3.4 0.7 0.4 0 0.4 0.4 342 14 336 305 0 0 0 0 0.4 0.1 1 0.1 05/08/2005 15:00:00 1.9 0.5 3 0.7 2.3 0.4 3.8 1.5 0.4 0 0.4 0.4 341 15 353 305 0 0 0 0 0.6 0.1 1 0.3 05/08/2005 15:10:00 1.9 0.5 3.8 0.4 2.3 0.4 3.4 1.1 0.4 0 0.4 0.4 340 10 338 305 0 0 0 0 0.4 0.1 0.8 0.1 05/08/2005 15:20:00 1.8 0.5 3 0.7 2.2 0.5 3.4 0.7 0.4 0 0.4 0.4 341 13 341 305 0 0 0 0 0.5 0.1 1 0.3 05/08/2005 15:30:00 1.7 0.5 3 0.4 2.1 0.5 3.4 0.7 0.4 0 0.4 0.4 0 11 350 305 0 0 0 0 0.3 0.2 0.8 0.1 05/08/2005 15:40:00 1.7 0.5 3 0.4 1.9 0.5 3 0.4 0.4 0 0.4 0.4 350 15 343 305 0 0 0 0 0.3 0 0.6 0.1 05/08/2005 15:50:00 1.7 0.6 3.4 0.4 2 0.4 3 1.1 0.4 0 0.4 0.4 358 13 25 305 0 0 0 0 0.1 0.1 0.3 -0.4 05/08/2005 16:00:00 1.5 0.4 2.6 0.4 1.9 0.4 3 0.4 0.4 0 0.4 0.4 346 12 335 305 0 0 0 0 -0.1 0 0.1 -0.4 05/08/2005 16:10:00 1.2 0.5 2.3 0.4 1.6 0.4 2.6 0.4 0.4 0 0.4 0.4 339 14 339 305 0 0 0 0 0 0 0.3 -0.1 05/08/2005 16:20:00 0.8 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.4 0 0.4 0.4 352 16 358 305 0 0 0 0 0 0 0.3 -0.1 05/08/2005 16:30:00 1.2 0.5 3 0.4 1.6 0.4 3.4 0.7 0.4 0 0.4 0.4 351 12 351 305 0 0 0 0 -0.3 0 0.3 -0.4 05/08/2005 16:40:00 1.2 0.5 2.6 0.4 1.6 0.5 2.6 0.4 0.4 0 0.4 0.4 352 17 13 305 0 0 0 0 -0.4 0.1 0.1 -0.6 05/08/2005 16:50:00 1.4 0.4 2.3 0.4 1.7 0.4 2.6 0.4 0.4 0 0.4 0.4 3 18 19 305 0 0 0 0 0 0.1 0.6 -0.4 05/08/2005 17:00:00 0.8 0.4 1.9 0.4 1.3 0.4 2.3 0.4 0.4 0 0.4 0.4 6 14 20 305 0 0 0 0 -0.3 0.1 0.1 -0.6 05/08/2005 17:10:00 1.1 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.4 0 0.4 0.4 19 15 1 305 0 0 0 0 -0.1 0.2 0.3 -0.4 05/08/2005 17:20:00 1.8 0.5 3 0.4 2.1 0.4 3.4 1.1 0.4 0 0.4 0.4 13 9 21 305 0 0 0 0 -0.3 0.2 0.3 -0.6 05/08/2005 17:30:00 2.8 0.3 3.4 1.5 3 0.3 3.8 2.3 0.4 0 0.4 0.4 11 5 19 305 0 0 0 0 -0.5 0.1 0.1 -0.6 05/08/2005 17:40:00 2.3 0.4 3.4 1.5 2.5 0.4 3.4 1.5 0.4 0 0.4 0.4 19 8 18 305 0 0 0 0 -0.7 0.1 -0.1 -1.1 05/08/2005 17:50:00 1.3 0.4 2.3 0.4 1.8 0.3 2.6 0.7 0.4 0 0.4 0.4 6 8 3 305 0 0 0 0 -0.6 0.1 -0.1 -1.1 05/08/2005 18:00:00 1 0.4 1.9 0.4 1.5 0.4 2.6 0.7 0.4 0 0.4 0.4 17 8 8 305 0 0 0 0 -0.7 0 -0.4 -0.8 05/08/2005 18:10:00 1.8 0.6 3 0.4 2.1 0.5 3 1.1 0.4 0 0.4 0.4 20 8 19 305 0 0 0 0 -0.7 0.1 -0.1 -1.1 05/08/2005 18:20:00 1.3 0.4 2.3 0.4 1.8 0.3 2.6 1.1 0.4 0 0.4 0.4 30 9 31 305 0 0 0 0 -1 0.1 -0.4 -1.1 05/08/2005 18:30:00 1.1 0.5 2.6 0.4 1.6 0.4 2.6 0.7 0.4 0 0.4 0.4 19 8 16 305 0 0 0 0 -0.8 0 -0.4 -1.1 05/08/2005 18:40:00 1 0.5 2.3 0.4 1.4 0.4 2.6 0.4 0.4 0 0.4 0.4 29 9 28 305 0 0 0 0 -0.8 0 -0.4 -1.1 05/08/2005 18:50:00 1.6 0.4 2.3 0.4 2 0.3 2.6 1.1 0.4 0 0.4 0.4 29 8 35 305 0 0 0 0 -1 0.1 -0.6 -1.1 05/08/2005 19:00:00 1.4 0.4 2.6 0.4 1.9 0.3 2.6 1.1 0.4 0 0.4 0.4 29 9 47 305 0 0 0 0 -1 0.1 -0.6 -1.1 05/08/2005 19:10:00 1.9 0.4 2.6 1.1 2.2 0.3 3 1.5 0.4 0 0.4 0.4 28 6 34 305 0 0 0 0 -0.8 0 -0.4 -1.1 05/08/2005 19:20:00 1.8 0.4 2.6 0.7 2.1 0.3 3 1.1 0.4 0 0.4 0.4 44 10 17 305 0 0 0 0 -0.6 0 -0.1 -0.8 05/08/2005 19:30:00 1.3 0.4 2.6 0.4 1.8 0.4 3 0.7 0.4 0 0.4 0.4 27 10 32 305 0 0 0 0 -0.5 0 -0.4 -0.6 05/08/2005 19:40:00 1.5 0.4 2.3 0.4 1.9 0.4 3 1.1 0.4 0 0.4 0.4 36 9 52 305 0 0 0 0 -0.7 0 -0.4 -1.1 05/08/2005 19:50:00 1.3 0.5 2.3 0.4 1.8 0.3 2.6 1.1 0.4 0 0.4 0.4 42 10 44 305 0 0 0 0 -0.8 0.1 -0.4 -1.1 05/08/2005 20:00:00 1.5 0.4 2.3 0.4 1.9 0.3 3 1.1 0.4 0 0.4 0.4 41 11 30 305 0 0 0 0 -0.7 0.1 -0.4 -0.8 05/08/2005 20:10:00 1.8 0.3 2.6 1.1 2.2 0.3 3 1.5 0.4 0 0.4 0.4 32 6 42 305 0 0 0 0 -0.8 0.2 -0.4 -1.1 05/08/2005 20:20:00 2.3 0.2 3 1.9 2.5 0.2 3.4 1.9 0.4 0 0.4 0.4 35 5 41 305 0 0 0 0 -1 0.1 -0.6 -1.1 05/08/2005 20:30:00 2.4 0.3 3 1.5 2.7 0.3 3.4 1.9 0.4 0 0.4 0.4 38 6 29 305 0 0 0 0 -1 0.1 -0.6 -1.1 05/08/2005 20:40:00 2.1 0.3 2.6 1.1 2.4 0.2 3 1.9 0.4 0 0.4 0.4 43 4 50 305 0 0 0 0 -1 0.1 -0.6 -1.3 05/08/2005 20:50:00 1.7 0.3 2.6 1.1 2.1 0.3 2.6 1.5 0.4 0 0.4 0.4 39 5 34 305 0 0 0 0 -1.1 0.1 -0.6 -1.3 05/08/2005 21:00:00 1.6 0.3 2.3 0.4 2 0.3 2.6 1.1 0.4 0 0.4 0.4 48 7 39 305 0 0 0 0 -1.1 0.1 -0.6 -1.3 05/08/2005 21:10:00 1.5 0.3 2.3 0.4 1.8 0.2 2.3 1.1 0.4 0 0.4 0.4 63 5 71 305 0 0 0 0 -1.1 0.1 -0.6 -1.3 05/08/2005 21:20:00 1.1 0.4 1.9 0.4 1.6 0.3 2.3 0.7 0.4 0 0.4 0.4 62 7 57 305 1 0 1 0 -1.1 0.1 -0.6 -1.3 05/08/2005 21:30:00 1 0.3 1.9 0.4 1.5 0.2 2.3 1.1 0.4 0 0.4 0.4 55 4 58 305 1 0 1 0 -1.2 0.1 -0.6 -1.3 05/08/2005 21:40:00 0.9 0.4 1.9 0.4 1.5 0.3 2.3 0.7 0.4 0 0.7 0.4 63 6 62 305 1 0 1 0 -1.3 0.1 -0.8 -1.5 05/08/2005 21:50:00 1.4 0.3 1.9 0.7 1.8 0.3 2.3 1.1 0.4 0 0.4 0.4 49 4 53 305 2 0 1 0 -1.4 0.1 -0.8 -1.5 05/08/2005 22:00:00 1.7 0.2 2.3 1.1 2 0.2 2.3 1.1 0.4 0 0.4 0.4 50 7 46 305 2 0 2 0 -1.4 0.1 -0.8 -1.5 05/08/2005 22:10:00 1.6 0.2 2.3 1.1 1.9 0.2 2.3 1.1 0.4 0 0.4 0.4 60 5 55 305 3 0 2 0 -1.5 0.1 -1.1 -1.8 05/08/2005 22:20:00 1.7 0.2 2.3 1.1 2 0.2 2.3 1.5 0.4 0 0.4 0.4 60 3 61 305 3 0 3 0 -1.6 0 -1.3 -1.8 05/08/2005 22:30:00 1.9 0.2 2.3 1.5 2.2 0.2 2.6 1.9 0.4 0 0.4 0.4 49 4 46 305 4 0 4 0 -1.6 0 -1.3 -1.8 05/08/2005 22:40:00 2.2 0.3 2.6 1.5 2.4 0.2 2.6 1.9 0.4 0 0.4 0.4 55 3 55 305 4 0 4 0 -1.6 0 -1.3 -1.8 05/08/2005 22:50:00 2.3 0.2 2.6 1.5 2.4 0.2 3 1.9 0.4 0 0.4 0.4 53 3 52 305 5 0 5 0 -1.6 0 -1.3 -1.8 05/08/2005 23:00:00 1.7 0.3 2.6 1.1 1.9 0.3 2.6 1.5 0.4 0 0.4 0.4 58 5 57 305 7 0 6 0 -1.7 0 -1.3 -1.8 05/08/2005 23:10:00 1.9 0.2 2.3 1.1 2.1 0.2 2.6 1.5 0.4 0 0.4 0.4 55 8 64 305 8 0 8 0 -1.8 0 -1.3 -2 05/08/2005 23:20:00 2.2 0.2 2.6 1.5 2.4 0.2 3 1.9 0.4 0 0.4 0.4 52 4 50 305 10 1 10 0 -1.8 0 -1.3 -2 05/08/2005 23:30:00 2.5 0.2 3 1.9 2.6 0.2 3 1.9 0.4 0 0.4 0.4 56 3 58 305 13 0 12 0 -1.8 0 -1.3 -2 05/08/2005 23:40:00 2.2 0.3 2.6 1.9 2.4 0.2 3 1.9 0.4 0 0.4 0.4 64 5 67 305 14 0 14 0 -1.8 0.1 -1.3 -2 05/08/2005 23:50:00 2.1 0.2 2.3 1.5 2.2 0.2 2.6 1.9 0.4 0 0.4 0.4 65 2 68 305 16 0 15 0 -2.1 0.1 -1.8 -2.2 05/09/2005 00:00:00 2.2 0.3 3 1.5 2.3 0.2 2.6 1.9 0.4 0 0.4 0.4 58 3 59 305 16 0 16 0 -2 0.1 -1.5 -2 05/09/2005 00:10:00 2.1 0.3 2.6 1.5 2.3 0.2 3 1.5 0.4 0 0.4 0.4 64 6 68 305 17 0 16 0 -1.9 0 -1.3 -2 05/09/2005 00:20:00 2.8 0.3 3.8 1.9 2.8 0.3 3.8 2.3 0.4 0 0.4 0.4 67 3 64 305 19 1 20 0 -1.9 0.1 -1.3 -2 05/09/2005 00:30:00 3.5 0.4 4.2 2.6 3.5 0.4 4.2 2.6 0.4 0 0.4 0.4 55 4 51 305 22 1 22 0 -1.8 0 -1.3 -2 05/09/2005 00:40:00 4.1 0.3 4.6 3.4 4.2 0.3 4.9 3 0.4 0 0.4 0.4 50 4 54 305 25 1 27 0 -1.8 0 -1.3 -2 05/09/2005 00:50:00 4.1 0.2 4.6 3.8 4.2 0.3 4.9 3.4 0.4 0 0.4 0.4 46 3 48 305 29 1 30 0 -1.8 0 -1.3 -2 05/09/2005 01:00:00 4.4 0.3 4.9 3.4 4.5 0.3 5.3 3.4 0.4 0 0.4 0.4 45 4 49 305 33 1 33 0 -1.8 0 -1.3 -2 05/09/2005 01:10:00 4.8 0.2 5.3 4.2 5 0.2 5.7 4.2 0.4 0 0.4 0.4 47 3 44 305 37 1 39 0 -1.8 0 -1.3 -2 05/09/2005 01:20:00 4.6 0.3 5.3 3.8 4.6 0.4 5.3 3.4 0.4 0 0.4 0.4 52 5 49 305 40 1 39 0 -1.9 0 -1.3 -2 05/09/2005 01:30:00 4.5 0.3 5.3 3.8 4.6 0.3 5.3 3.8 0.4 0 0.4 0.4 55 3 55 305 43 1 42 0 -1.9 0 -1.3 -2 05/09/2005 01:40:00 4.2 0.3 4.9 3.4 4.1 0.4 4.9 3 0.4 0 0.4 0.4 57 4 53 305 46 1 47 0 -2 0.1 -1.3 -2.2 05/09/2005 01:50:00 4.5 0.5 5.3 3 4.4 0.6 5.7 3 0.4 0 0.4 0.4 56 5 57 305 49 1 50 0 -2.1 0.1 -1.5 -2.2 05/09/2005 02:00:00 4.9 0.2 5.7 4.2 5 0.2 5.7 4.6 0.4 0 0.4 0.4 53 3 52 305 52 1 53 0 -1.9 0 -1.3 -2 05/09/2005 02:10:00 5.1 0.3 5.7 4.6 5.2 0.3 5.7 4.2 0.4 0 0.4 0.4 52 3 51 305 56 1 55 0 -1.9 0.1 -1.3 -2 05/09/2005 02:20:00 5.5 0.3 6.1 4.6 5.6 0.3 6.1 4.6 0.4 0 0.4 0.4 47 3 43 305 59 1 59 0 -1.9 0 -1.3 -2 05/09/2005 02:30:00 5.4 0.3 6.1 4.6 5.5 0.4 6.5 4.6 0.4 0 0.4 0.4 47 4 53 305 62 1 62 0 -1.9 0 -1.3 -2 05/09/2005 02:40:00 5.6 0.3 6.1 4.9 5.7 0.3 6.5 4.6 0.4 0 0.4 0.4 48 4 50 305 64 1 64 0 -1.9 0.1 -1.3 -2 05/09/2005 02:50:00 5.9 0.3 6.5 5.3 5.9 0.4 6.8 4.9 0.4 0 0.4 0.4 47 3 46 305 66 0 66 0 -1.9 0 -1.3 -2 05/09/2005 03:00:00 6.3 0.4 6.8 5.3 6.4 0.4 7.2 4.9 0.4 0 0.4 0.4 46 3 43 305 67 0 67 0 -2 0 -1.5 -2 05/09/2005 03:10:00 6.9 0.4 7.6 6.1 7 0.5 8 5.3 0.4 0 0.4 0.4 47 3 51 305 69 0 69 0 -2 0 -1.8 -2 05/09/2005 03:20:00 7 0.5 8.4 5.7 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 47 3 48 305 70 0 70 0 -1.9 0 -1.8 -2 05/09/2005 03:30:00 6.5 0.5 7.2 4.6 6.5 0.6 7.2 4.6 0.4 0 0.4 0.4 52 3 56 305 72 0 72 0 -2 0 -1.8 -2 05/09/2005 03:40:00 6.5 0.5 7.2 5.3 6.6 0.5 7.6 4.9 0.4 0 0.4 0.4 52 3 53 305 74 0 74 0 -2 0 -1.8 -2.2 05/09/2005 03:50:00 7.1 0.4 8 6.1 7.2 0.4 8 6.1 0.4 0 0.4 0.4 53 2 54 305 76 0 76 0 -2 0 -1.8 -2 05/09/2005 04:00:00 6.7 0.4 7.6 5.7 6.8 0.4 7.6 5.7 0.4 0 0.4 0.4 53 3 53 305 77 0 76 0 -1.9 0 -1.5 -2 05/09/2005 04:10:00 6.9 0.4 7.6 6.1 7.1 0.4 8 5.7 0.4 0 0.4 0.4 51 3 47 305 78 0 78 0 -1.9 0 -1.8 -2 05/09/2005 04:20:00 7.4 0.5 8.4 5.7 7.5 0.5 8.4 5.7 0.4 0 0.4 0.4 49 3 51 305 78 0 78 0 -1.9 0 -1.8 -2 05/09/2005 04:30:00 7.1 0.5 8.4 5.3 7.1 0.6 8 4.9 0.4 0 0.4 0.4 47 4 48 305 79 0 79 0 -2 0 -1.8 -2 05/09/2005 04:40:00 7.6 0.5 8.4 6.5 7.6 0.6 8.8 5.7 0.4 0 0.4 0.4 38 5 35 305 80 0 80 0 -2 0.1 -1.8 -2.2 05/09/2005 04:50:00 7.7 0.5 8.8 6.1 7.7 0.5 8.8 6.1 0.4 0 0.4 0.4 37 4 34 305 82 0 81 0 -2.2 0 -2 -2.4 05/09/2005 05:00:00 8 0.5 9.5 6.1 7.9 0.6 9.1 5.7 0.4 0 0.4 0.4 44 4 39 305 83 0 82 0 -2.2 0 -2 -2.2 05/09/2005 05:10:00 8.3 0.7 9.9 6.5 8.3 0.8 10.3 5.7 0.4 0 0.4 0.4 46 4 47 305 83 1 83 0 -2 0 -1.8 -2.2 05/09/2005 05:20:00 8.6 0.7 9.9 6.5 8.5 0.8 9.9 5.7 0.4 0 0.4 0.4 42 5 46 305 86 0 86 0 -2 0.1 -1.8 -2.2 05/09/2005 05:30:00 8.7 0.5 9.5 6.8 8.7 0.6 9.9 6.5 0.4 0 0.4 0.4 37 4 33 305 87 0 87 0 -2.3 0 -2 -2.7 05/09/2005 05:40:00 9.2 0.6 10.3 7.6 9.2 0.7 10.7 6.8 0.4 0 0.4 0.4 44 5 43 305 88 0 88 0 -2.6 0 -2.4 -2.7 05/09/2005 05:50:00 9.2 0.5 10.3 8 9.2 0.6 10.7 7.2 0.4 0 0.4 0.4 47 6 43 305 89 0 90 0 -2.7 0 -2.4 -2.7 05/09/2005 06:00:00 9.4 0.5 10.7 8.4 9.5 0.5 10.7 7.2 0.4 0 0.4 0.4 49 6 50 305 90 0 90 0 -2.8 0 -2.7 -2.9 05/09/2005 06:10:00 8.5 0.6 9.9 6.5 8.5 0.7 9.9 6.5 0.4 0 0.4 0.4 49 5 47 305 91 0 91 0 -2.7 0 -2.4 -2.9 05/09/2005 06:20:00 8.5 0.5 9.9 7.2 8.5 0.6 10.3 6.8 0.4 0 0.4 0.4 49 5 54 305 92 0 92 0 -2.8 0 -2.7 -2.9 05/09/2005 06:30:00 8.7 0.6 10.3 7.2 8.8 0.6 10.7 7.2 0.4 0 0.4 0.4 44 5 55 305 93 0 92 0 -2.9 0 -2.7 -3.1 05/09/2005 06:40:00 8 0.6 9.1 6.5 8 0.7 9.5 6.1 0.4 0 0.4 0.4 53 4 54 305 93 0 94 0 -2.9 0 -2.7 -3.1 05/09/2005 06:50:00 7.5 0.5 8.4 5.7 7.6 0.5 8.8 5.7 0.4 0 0.4 0.4 46 8 44 305 94 0 94 0 -2.8 0 -2.4 -3.1 05/09/2005 07:00:00 7.6 0.7 9.1 6.1 7.5 0.8 9.5 5.7 0.4 0 0.4 0.4 42 5 44 305 94 0 94 0 -2.7 0 -2.4 -2.7 05/09/2005 07:10:00 7.3 0.6 9.1 5.7 7.3 0.7 9.1 5.3 0.4 0 0.4 0.4 41 8 34 305 95 0 95 0 -2.7 0 -2.7 -2.9 05/09/2005 07:20:00 7.3 0.6 8.8 5.3 7.4 0.8 8.8 5.3 0.4 0 0.4 0.4 43 7 31 305 95 0 95 0 -2.8 0 -2.7 -3.1 05/09/2005 07:30:00 6.3 0.6 7.6 4.9 6.5 0.6 8 4.6 0.4 0 0.4 0.4 42 6 46 305 95 0 95 0 -2.7 0 -2.4 -2.7 05/09/2005 07:40:00 5.6 0.5 6.8 4.6 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 50 5 45 305 95 0 95 0 -2.7 0 -2.4 -2.7 05/09/2005 07:50:00 6.4 0.4 7.6 5.3 6.5 0.5 7.6 4.6 0.4 0 0.4 0.4 48 3 50 305 95 0 94 0 -2.3 0.1 -2 -2.7 05/09/2005 08:00:00 5.9 0.5 7.2 4.9 6.1 0.6 7.6 4.6 0.4 0 0.4 0.4 43 4 42 305 95 0 95 0 -1.8 0.1 -1.8 -2 05/09/2005 08:10:00 6.3 0.5 7.6 4.6 6.2 0.6 7.2 4.9 0.4 0 0.4 0.4 45 4 42 305 95 0 95 0 -1.5 0.1 -1.1 -1.8 05/09/2005 08:20:00 6.1 0.4 7.2 4.9 6.2 0.5 7.2 4.9 0.4 0 0.4 0.4 42 3 39 305 95 0 95 0 -1.3 0 -1.1 -1.3 05/09/2005 08:30:00 6.6 0.6 8.4 5.3 6.6 0.6 8.4 4.9 0.4 0 0.4 0.4 44 4 48 305 97 1 98 0 -1.1 0 -0.8 -1.1 05/09/2005 08:40:00 7.7 0.7 9.1 5.7 7.5 0.8 9.5 5.3 0.4 0 0.4 0.4 45 4 50 305 98 0 98 0 -0.9 0 -0.6 -1.1 05/09/2005 08:50:00 8.8 0.6 9.9 7.2 8.6 0.7 10.3 6.8 0.4 0 0.4 0.4 47 3 48 305 98 0 97 0 -0.8 0 -0.4 -1.1 05/09/2005 09:00:00 9 0.9 10.7 6.8 8.8 1 11.1 6.5 0.4 0 0.4 0.4 45 3 51 305 96 0 96 0 -0.7 0 -0.4 -0.8 05/09/2005 09:10:00 9.6 0.8 11.1 7.2 9.4 0.9 11.1 6.5 0.4 0 0.4 0.4 42 4 44 305 95 0 95 0 -0.8 0.2 -0.1 -1.1 05/09/2005 09:20:00 9.7 0.8 11.1 7.2 9.5 0.8 11.1 6.8 0.4 0 0.4 0.4 39 4 41 305 95 0 95 0 -1 0.1 -0.4 -1.1 05/09/2005 09:30:00 10.3 0.8 12.6 8.4 10.3 0.9 12.6 8 0.4 0 0.4 0.4 41 3 44 305 96 0 96 0 -0.9 0.1 -0.4 -1.1 05/09/2005 09:40:00 10 0.6 11.5 8 10 0.6 11.5 8.4 0.4 0 0.4 0.4 38 3 35 305 95 0 95 0 -1 0 -0.6 -1.1 05/09/2005 09:50:00 10.2 0.6 11.8 8.4 10 0.7 11.5 8 0.4 0 0.4 0.4 38 3 39 305 95 0 95 0 -1.1 0 -0.6 -1.1 05/09/2005 10:00:00 9.7 0.8 11.5 8 9.5 0.9 11.5 7.6 0.4 0 0.4 0.4 37 4 35 305 96 0 96 0 -1.1 0 -0.6 -1.3 05/09/2005 10:10:00 10.6 0.6 11.8 8.8 10.5 0.7 12.2 8.8 0.4 0 0.4 0.4 40 3 36 305 96 0 96 0 -1.1 0 -0.6 -1.3 05/09/2005 10:20:00 9.9 0.9 11.8 7.6 9.8 0.9 12.2 7.6 0.4 0 0.4 0.4 41 3 40 305 95 0 95 0 -1.1 0 -0.6 -1.3 05/09/2005 10:30:00 11.1 0.5 12.2 9.5 11.2 0.5 12.6 9.9 0.4 0 0.4 0.4 42 3 39 305 94 0 94 0 -1.2 0 -0.6 -1.3 05/09/2005 10:40:00 11.4 0.6 12.6 9.9 11.4 0.7 12.6 9.1 0.4 0 0.4 0.4 41 3 46 305 95 1 94 0 -1.2 0 -0.6 -1.3 05/09/2005 10:50:00 11.6 0.5 12.6 9.5 11.5 0.7 12.6 8.8 0.4 0 0.4 0.4 42 2 41 305 96 0 96 0 -1.2 0 -0.6 -1.3 05/09/2005 11:00:00 11 0.7 12.6 8.8 10.8 0.8 12.2 8.4 0.4 0 0.4 0.4 43 4 43 305 95 0 95 0 -1.1 0 -0.6 -1.3 05/09/2005 11:10:00 10.5 0.7 12.2 8.4 10.3 0.9 12.2 7.6 0.4 0 0.4 0.4 43 4 45 305 95 0 95 0 -1.1 0 -0.6 -1.3 05/09/2005 11:20:00 10.5 0.8 12.2 8.4 10.3 1 12.2 8 0.4 0 0.4 0.4 44 4 48 305 94 0 94 0 -1.2 0 -1.1 -1.3 05/09/2005 11:30:00 10.7 0.8 12.6 8.4 10.5 1 12.6 8 0.4 0 0.4 0.4 43 4 49 305 94 0 94 0 -1.2 0 -1.1 -1.3 05/09/2005 11:40:00 10.5 0.8 12.2 8.8 10.3 0.9 12.2 8 0.4 0 0.4 0.4 42 4 43 305 93 0 93 0 -1.2 0 -1.1 -1.3 05/09/2005 11:50:00 10.9 0.8 12.2 8.4 10.8 0.9 12.2 8 0.4 0 0.4 0.4 40 4 37 305 92 0 93 0 -1.3 0 -1.1 -1.5 05/09/2005 12:00:00 10.4 0.8 12.2 8.4 10.4 0.8 12.2 8.4 0.4 0 0.4 0.4 37 3 38 305 92 0 92 0 -1.2 0 -1.1 -1.3 05/09/2005 12:10:00 9.8 0.9 11.5 7.2 9.7 1 11.8 7.2 0.4 0 0.4 0.4 34 4 40 305 91 0 92 0 -1.2 0 -1.1 -1.3 05/09/2005 12:20:00 9.4 0.6 11.1 7.2 9.3 0.8 11.1 7.6 0.4 0 0.4 0.4 34 4 29 305 91 0 91 0 -1.2 0 -1.1 -1.3 05/09/2005 12:30:00 10 1 11.8 7.2 10 1 11.8 7.6 0.4 0 0.4 0.4 34 4 32 305 90 0 90 0 -1.4 0 -1.3 -1.8 05/09/2005 12:40:00 9.8 1 11.8 6.5 9.8 1 11.8 6.8 0.4 0 0.4 0.4 35 5 35 305 90 0 90 0 -1.5 0 -1.3 -1.8 05/09/2005 12:50:00 10 0.9 11.8 7.6 10 0.8 12.2 8 0.4 0 0.4 0.4 37 3 37 305 91 0 91 0 -1.5 0 -1.3 -1.8 05/09/2005 13:00:00 9.9 0.8 11.8 7.6 9.8 0.8 11.8 7.2 0.4 0 0.4 0.4 42 4 43 305 91 0 92 0 -1.4 0 -1.1 -1.5 05/09/2005 13:10:00 9.9 0.8 11.5 8 9.9 0.9 11.8 7.6 0.4 0 0.4 0.4 43 4 45 305 92 0 92 0 -1.4 0 -1.3 -1.8 05/09/2005 13:20:00 9.7 0.8 11.1 8 9.5 0.9 11.5 7.2 0.4 0 0.4 0.4 42 5 43 305 92 0 92 0 -1.4 0 -1.1 -1.5 05/09/2005 13:30:00 9.5 1 11.5 7.2 9.4 1.1 11.8 6.8 0.4 0 0.4 0.4 43 5 37 305 92 0 92 0 -1.4 0 -0.6 -1.8 05/09/2005 13:40:00 9.5 0.9 11.5 7.2 9.4 1 11.8 7.2 0.4 0 0.4 0.4 42 5 42 305 92 0 92 0 -1.2 0 -0.6 -1.3 05/09/2005 13:50:00 9.5 0.8 11.5 7.6 9.4 0.9 11.5 7.2 0.4 0 0.4 0.4 42 5 49 305 91 0 92 0 -1.2 0 -0.6 -1.3 05/09/2005 14:00:00 10.3 0.7 11.8 8.8 10.1 0.7 11.8 7.6 0.4 0 0.4 0.4 38 5 43 305 92 0 92 0 -1.2 0 -0.6 -1.3 05/09/2005 14:10:00 10.1 0.7 11.5 8 10 0.8 11.5 7.2 0.4 0 0.4 0.4 42 4 42 305 90 0 91 0 -1.2 0 -0.6 -1.3 05/09/2005 14:20:00 10.5 0.7 12.2 8.8 10.5 0.8 12.2 8.4 0.4 0 0.4 0.4 39 4 38 305 89 0 89 0 -1.2 0 -0.6 -1.3 05/09/2005 14:30:00 10.2 0.9 12.6 8 10.1 1 12.6 7.2 0.4 0 0.4 0.4 40 4 42 305 87 0 87 0 -1.1 0 -0.6 -1.3 05/09/2005 14:40:00 9.8 0.8 11.8 7.6 9.7 1 11.8 7.2 0.4 0 0.4 0.4 43 4 40 305 85 0 85 0 -1 0.1 -0.4 -1.1 05/09/2005 14:50:00 10.6 0.8 12.2 8 10.5 0.8 12.2 8 0.4 0 0.4 0.4 44 4 45 305 84 0 84 0 -1 0.1 -0.4 -1.3 05/09/2005 15:00:00 11.1 0.7 12.6 9.1 11 0.8 13 8.8 0.4 0 0.4 0.4 41 4 40 305 82 0 83 0 -1.2 0 -0.6 -1.3 05/09/2005 15:10:00 9.7 0.7 11.5 7.6 9.6 0.8 11.5 7.6 0.4 0 0.4 0.4 41 5 50 305 81 0 81 0 -1.1 0 -0.6 -1.3 05/09/2005 15:20:00 10 0.5 11.1 8.4 9.9 0.5 11.1 8.4 0.4 0 0.4 0.4 40 4 38 305 79 0 80 0 -1.4 0 -0.6 -1.5 05/09/2005 15:30:00 10.2 0.6 11.8 8.8 10.2 0.6 11.8 8.8 0.4 0 0.4 0.4 41 3 42 305 78 0 79 0 -1.2 0 -0.6 -1.3 05/09/2005 15:40:00 9.3 0.5 10.7 8 9.3 0.5 10.7 8 0.4 0 0.4 0.4 39 4 35 305 77 0 77 0 -1.4 0 -0.8 -1.5 05/09/2005 15:50:00 9.3 0.5 11.1 8 9.2 0.5 10.7 7.6 0.4 0 0.4 0.4 38 4 41 305 77 0 77 0 -1.2 0 -1.1 -1.5 05/09/2005 16:00:00 9.1 0.6 10.3 7.6 9 0.6 10.3 7.2 0.4 0 0.4 0.4 36 4 35 305 77 0 77 0 -1.1 0 -1.1 -1.3 05/09/2005 16:10:00 9.1 0.6 10.7 7.6 9.1 0.6 10.7 7.2 0.4 0 0.4 0.4 36 4 38 305 76 0 77 0 -1.1 0 -0.8 -1.3 05/09/2005 16:20:00 8.7 0.8 10.3 6.5 8.7 0.8 10.3 6.8 0.4 0 0.4 0.4 36 5 34 305 76 0 76 0 -1.1 0 -1.1 -1.3 05/09/2005 16:30:00 8.7 0.7 10.3 7.2 8.7 0.7 10.3 6.8 0.4 0 0.4 0.4 36 5 36 305 75 0 75 0 -1.2 0 -1.1 -1.3 05/09/2005 16:40:00 9.4 0.7 11.1 8 9.4 0.8 11.5 7.6 0.4 0 0.4 0.4 40 4 39 305 75 0 75 0 -1.3 0 -1.1 -1.5 05/09/2005 16:50:00 9.4 0.7 11.1 7.6 9.4 0.7 11.1 7.6 0.4 0 0.4 0.4 45 4 45 305 76 0 76 0 -1.1 0 -1.1 -1.3 05/09/2005 17:00:00 10.3 0.6 11.8 8.4 10.2 0.7 11.5 8 0.4 0 0.4 0.4 42 3 39 305 77 0 77 0 -1.2 0 -0.6 -1.3 05/09/2005 17:10:00 9.7 0.5 11.1 8 9.6 0.6 10.7 8.4 0.4 0 0.4 0.4 44 4 41 305 77 0 77 0 -1.1 0 -0.6 -1.3 05/09/2005 17:20:00 9 0.8 11.1 6.8 9 0.8 11.1 6.8 0.4 0 0.4 0.4 41 5 43 305 77 0 77 0 -1.1 0 -0.6 -1.3 05/09/2005 17:30:00 9.3 0.6 10.7 8 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 40 5 40 305 77 0 77 0 -1.1 0 -0.6 -1.3 05/09/2005 17:40:00 9.4 0.6 10.7 7.6 9.4 0.6 11.1 7.6 0.4 0 0.4 0.4 39 4 40 305 77 0 77 0 -1.1 0 -0.6 -1.3 05/09/2005 17:50:00 9.1 0.7 10.7 7.2 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 37 4 41 305 77 0 77 0 -1.1 0 -1.1 -1.3 05/09/2005 18:00:00 7.7 0.6 9.9 6.5 7.8 0.6 9.5 6.1 0.4 0 0.4 0.4 39 4 42 305 77 0 77 0 -1.1 0 -0.6 -1.1 05/09/2005 18:10:00 8 0.7 9.5 6.5 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 36 5 36 305 77 0 77 0 -1.1 0 -0.6 -1.3 05/09/2005 18:20:00 8 0.6 9.9 6.5 8 0.7 9.9 6.1 0.4 0 0.4 0.4 37 5 35 305 77 0 77 0 -1.1 0 -0.6 -1.1 05/09/2005 18:30:00 8.1 0.7 9.5 6.1 8 0.7 9.5 6.1 0.4 0 0.4 0.4 37 4 41 305 77 0 77 0 -1.1 0 -0.6 -1.1 05/09/2005 18:40:00 8.9 0.6 9.9 6.8 8.7 0.6 9.9 6.8 0.4 0 0.4 0.4 38 4 32 305 77 0 77 0 -1.1 0 -0.6 -1.1 05/09/2005 18:50:00 8.5 0.9 10.3 6.1 8.5 0.9 10.3 6.5 0.4 0 0.4 0.4 40 4 44 305 78 0 77 0 -1.1 0.1 -0.4 -1.3 05/09/2005 19:00:00 8 0.6 9.5 6.5 7.9 0.6 9.5 6.1 0.4 0 0.4 0.4 37 5 39 305 78 0 78 0 -1.1 0.1 -0.4 -1.1 05/09/2005 19:10:00 8 0.6 9.1 6.1 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 33 3 31 305 78 0 78 0 -1.1 0 -0.6 -1.3 05/09/2005 19:20:00 7.9 0.7 9.5 6.1 7.8 0.7 9.9 6.1 0.4 0 0.4 0.4 33 5 34 305 79 0 79 0 -1.1 0 -0.6 -1.1 05/09/2005 19:30:00 8.1 0.7 9.5 6.5 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 33 4 32 305 80 0 80 0 -1.1 0 -0.4 -1.1 05/09/2005 19:40:00 8.4 0.7 9.9 6.1 8.3 0.8 9.9 6.1 0.4 0 0.4 0.4 39 4 45 305 80 0 80 0 -1 0.1 -0.4 -1.1 05/09/2005 19:50:00 8.7 1 10.3 6.1 8.5 0.9 10.7 6.1 0.4 0 0.4 0.4 39 5 33 305 80 0 80 0 -1.1 0 -0.6 -1.3 05/09/2005 20:00:00 9.2 0.6 10.7 8 9.1 0.6 10.7 7.6 0.4 0 0.4 0.4 41 3 41 305 80 0 80 0 -1.1 0 -0.6 -1.3 05/09/2005 20:10:00 9.1 0.6 10.7 7.2 9 0.7 10.3 7.2 0.4 0 0.4 0.4 38 4 38 305 80 0 80 0 -1.1 0 -0.6 -1.3 05/09/2005 20:20:00 9.2 0.6 10.7 6.8 9.1 0.7 10.7 7.2 0.4 0 0.4 0.4 39 4 42 305 81 0 80 0 -1.1 0 -0.6 -1.3 05/09/2005 20:30:00 9.2 0.9 11.1 6.8 9 0.9 11.5 6.5 0.4 0 0.4 0.4 40 5 42 305 81 0 81 0 -1.1 0 -0.6 -1.3 05/09/2005 20:40:00 9.3 0.7 11.1 7.6 9.2 0.7 11.1 7.2 0.4 0 0.4 0.4 37 4 37 305 82 0 82 0 -1.1 0.1 -0.6 -1.3 05/09/2005 20:50:00 9.6 0.7 11.1 7.6 9.5 0.8 11.1 7.2 0.4 0 0.4 0.4 40 4 42 305 83 0 82 0 -1.2 0 -0.6 -1.3 05/09/2005 21:00:00 9.8 0.6 11.1 7.6 9.6 0.6 11.1 8 0.4 0 0.4 0.4 40 4 48 305 84 0 84 0 -1.3 0 -1.1 -1.3 05/09/2005 21:10:00 9.5 0.8 11.1 7.2 9.3 0.9 11.5 6.8 0.4 0 0.4 0.4 41 4 45 305 84 0 84 0 -1.3 0 -1.1 -1.3 05/09/2005 21:20:00 9.3 0.6 10.7 7.6 9.3 0.6 10.7 7.2 0.4 0 0.4 0.4 39 3 40 305 85 0 85 0 -1.4 0 -0.8 -1.5 05/09/2005 21:30:00 9 0.6 10.7 7.6 8.8 0.7 10.7 6.5 0.4 0 0.4 0.4 33 4 31 305 86 0 85 0 -1.4 0 -1.3 -1.5 05/09/2005 21:40:00 8.7 0.6 9.9 6.8 8.6 0.6 9.9 6.8 0.4 0 0.4 0.4 35 5 30 305 87 0 87 0 -1.5 0 -1.3 -1.8 05/09/2005 21:50:00 8.6 0.6 9.9 6.8 8.5 0.5 9.9 7.2 0.4 0 0.4 0.4 30 4 29 305 88 0 88 0 -1.5 0 -1.3 -1.8 05/09/2005 22:00:00 8.5 0.6 9.9 6.8 8.4 0.8 9.9 6.1 0.4 0 0.4 0.4 36 3 34 305 89 0 90 0 -1.5 0 -1.3 -1.8 05/09/2005 22:10:00 8.9 0.5 9.9 7.2 8.8 0.5 9.9 7.2 0.4 0 0.4 0.4 36 4 34 305 90 0 90 0 -1.6 0 -1.5 -1.8 05/09/2005 22:20:00 8.7 0.6 10.3 7.2 8.4 0.7 9.9 6.8 0.4 0 0.4 0.4 39 6 46 305 91 0 91 0 -1.6 0 -1.5 -1.8 05/09/2005 22:30:00 9.5 0.5 10.7 8 9.4 0.5 10.7 7.2 0.4 0 0.4 0.4 34 3 33 305 92 0 92 0 -1.7 0 -1.3 -1.8 05/09/2005 22:40:00 9.5 0.4 10.3 8.4 9.5 0.5 10.7 8 0.4 0 0.4 0.4 37 3 40 305 94 0 93 0 -1.7 0 -1.8 -1.8 05/09/2005 22:50:00 9.8 0.4 10.7 8.4 9.7 0.5 11.1 8.4 0.4 0 0.4 0.4 38 3 40 305 94 0 94 0 -1.8 0 -1.3 -2 05/09/2005 23:00:00 9.1 0.6 10.3 7.2 9 0.6 10.7 7.2 0.4 0 0.4 0.4 38 5 35 305 95 0 94 0 -1.9 0 -1.5 -2 05/09/2005 23:10:00 9.3 0.6 10.3 8 9.2 0.7 10.7 7.6 0.4 0 0.4 0.4 37 5 33 305 95 0 95 0 -2 0 -1.8 -2 05/09/2005 23:20:00 9.3 0.7 10.7 7.2 9.3 0.8 11.1 6.8 0.4 0 0.4 0.4 40 4 39 305 96 0 96 0 -2 0 -1.8 -2.2 05/09/2005 23:30:00 9.3 0.6 10.7 7.6 9.1 0.7 10.3 6.8 0.4 0 0.4 0.4 33 4 31 305 96 0 96 0 -2.1 0 -2 -2.2 05/09/2005 23:40:00 9.3 0.6 11.1 7.6 9.3 0.6 11.1 7.6 0.4 0 0.4 0.4 40 6 31 305 96 0 97 0 -2.1 0 -1.8 -2.2 05/09/2005 23:50:00 10.1 0.5 11.5 8.4 10.1 0.6 11.5 8 0.4 0 0.4 0.4 35 3 30 305 97 0 97 0 -2 0 -1.8 -2 05/10/2005 00:00:00 10 0.6 11.1 8.4 9.9 0.6 11.1 8.4 0.4 0 0.4 0.4 39 3 37 305 98 0 97 0 -2 0 -1.5 -2.2 05/10/2005 00:10:00 9.3 0.7 11.1 7.6 9.3 0.7 11.1 7.2 0.4 0 0.4 0.4 40 5 42 305 98 0 98 0 -2 0 -1.8 -2 05/10/2005 00:20:00 9.9 0.7 11.5 8 9.8 0.6 11.5 8 0.4 0 0.4 0.4 38 4 31 305 99 0 99 0 -2 0 -2 -2 05/10/2005 00:30:00 9.6 0.6 11.1 8.4 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 36 3 36 305 98 0 98 0 -2 0 -1.8 -2 05/10/2005 00:40:00 10 0.5 11.1 8.4 9.9 0.6 11.5 8.4 0.4 0 0.4 0.4 32 4 28 305 99 0 99 0 -2 0 -1.8 -2 05/10/2005 00:50:00 9.5 0.7 11.5 7.6 9.4 0.7 11.5 7.2 0.4 0 0.4 0.4 33 3 30 305 99 0 99 0 -2 0 -1.8 -2 05/10/2005 01:00:00 9.7 0.6 11.1 7.6 9.5 0.7 11.1 7.6 0.4 0 0.4 0.4 31 4 32 305 99 0 98 0 -2 0 -1.8 -2 05/10/2005 01:10:00 9.1 0.6 10.7 7.6 8.9 0.7 10.7 6.8 0.4 0 0.4 0.4 31 4 26 305 98 0 98 0 -2 0 -1.8 -2.2 05/10/2005 01:20:00 8.9 0.5 10.3 7.2 8.8 0.6 9.9 6.8 0.4 0 0.4 0.4 34 3 29 305 98 0 98 0 -2 0 -2 -2.2 05/10/2005 01:30:00 9.2 0.6 10.3 7.6 9.2 0.6 10.7 7.6 0.4 0 0.4 0.4 27 3 28 305 98 0 98 0 -2 0 -2 -2.2 05/10/2005 01:40:00 9.5 0.5 10.7 8 9.5 0.5 10.7 7.6 0.4 0 0.4 0.4 33 3 28 305 98 0 98 0 -2.2 0 -2 -2.2 05/10/2005 01:50:00 9 0.6 10.3 7.6 8.9 0.7 10.7 7.2 0.4 0 0.4 0.4 30 4 31 305 98 0 97 0 -2.2 0 -2 -2.4 05/10/2005 02:00:00 9.5 0.5 10.7 8.4 9.4 0.6 11.1 7.6 0.4 0 0.4 0.4 32 5 26 305 97 0 97 0 -2.2 0 -1.8 -2.4 05/10/2005 02:10:00 9.9 0.7 11.5 8.4 9.9 0.8 11.8 8 0.4 0 0.4 0.4 28 6 23 305 97 0 97 0 -2.2 0 -2 -2.4 05/10/2005 02:20:00 9 0.7 11.1 7.6 8.9 0.8 11.1 6.8 0.4 0 0.4 0.4 29 5 29 305 97 0 97 0 -2.2 0 -1.8 -2.4 05/10/2005 02:30:00 10 0.5 11.1 8 10 0.6 11.5 8 0.4 0 0.4 0.4 26 4 21 305 97 0 97 0 -2.2 0 -2 -2.4 05/10/2005 02:40:00 9.4 0.6 10.7 7.6 9.3 0.6 10.7 7.6 0.4 0 0.4 0.4 36 4 36 305 97 0 97 0 -2.3 0 -1.8 -2.4 05/10/2005 02:50:00 9.8 0.4 11.1 8.4 9.6 0.5 11.1 8 0.4 0 0.4 0.4 34 5 39 305 97 0 97 0 -2.3 0 -2 -2.4 05/10/2005 03:00:00 9.6 0.6 11.1 8 9.5 0.6 11.1 7.6 0.4 0 0.4 0.4 33 5 36 305 97 0 97 0 -2.2 0 -1.8 -2.4 05/10/2005 03:10:00 10.4 0.5 11.5 9.1 10.3 0.5 11.5 8.8 0.4 0 0.4 0.4 39 3 37 305 97 0 97 0 -2.4 0 -2.2 -2.4 05/10/2005 03:20:00 10.5 0.6 12.2 8.8 10.4 0.6 12.2 8.8 0.4 0 0.4 0.4 37 4 41 305 97 0 97 0 -2.3 0 -2.2 -2.4 05/10/2005 03:30:00 10.9 0.7 12.6 8.8 10.9 0.7 12.6 8.8 0.4 0 0.4 0.4 34 5 39 305 97 0 97 0 -2.3 0 -2.2 -2.4 05/10/2005 03:40:00 11 0.5 12.2 9.5 11.1 0.6 13 9.5 0.4 0 0.4 0.4 26 4 21 305 97 0 97 0 -2.3 0 -2.2 -2.4 05/10/2005 03:50:00 10.3 0.7 11.8 8 10.2 0.7 12.2 8 0.4 0 0.4 0.4 34 4 37 305 96 0 96 0 -2.3 0 -2 -2.4 05/10/2005 04:00:00 10.3 0.6 11.8 8.4 10.2 0.6 12.2 8.4 0.4 0 0.4 0.4 36 4 41 305 96 0 96 0 -2.4 0 -2.2 -2.7 05/10/2005 04:10:00 10.9 0.8 12.6 8.8 10.8 0.9 12.6 8.4 0.4 0 0.4 0.4 34 6 35 305 96 0 96 0 -2.4 0 -2.2 -2.7 05/10/2005 04:20:00 10.8 0.8 13 9.1 10.8 0.8 12.6 8.4 0.4 0 0.4 0.4 28 4 31 305 96 0 96 0 -2.4 0 -2 -2.7 05/10/2005 04:30:00 10.9 0.6 12.2 9.5 10.8 0.6 12.2 9.5 0.4 0 0.4 0.4 34 4 35 305 96 0 95 0 -2.4 0 -2.2 -2.7 05/10/2005 04:40:00 11.3 0.5 12.6 9.9 11.3 0.5 12.6 9.5 0.4 0 0.4 0.4 36 5 35 305 96 0 96 0 -2.3 0 -2.2 -2.4 05/10/2005 04:50:00 10.8 0.6 12.6 9.1 10.8 0.7 12.6 9.1 0.4 0 0.4 0.4 31 6 26 305 96 0 96 0 -2.3 0 -2.2 -2.4 05/10/2005 05:00:00 11.7 0.5 13.3 9.9 11.7 0.6 13.7 9.5 0.4 0 0.4 0.4 28 5 28 305 97 0 96 0 -2.4 0 -1.8 -2.4 05/10/2005 05:10:00 10.6 0.8 12.6 8.8 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 30 5 35 305 97 0 97 0 -2.4 0 -2.2 -2.7 05/10/2005 05:20:00 11.4 0.7 13 9.1 11.3 0.8 13 8.4 0.4 0 0.4 0.4 27 3 30 305 97 0 97 0 -2.5 0.1 -2.2 -2.7 05/10/2005 05:30:00 11.4 0.6 12.6 8.8 11.4 0.8 13 8.4 0.4 0 0.4 0.4 27 4 25 305 97 0 97 0 -2.5 0 -2.4 -2.7 05/10/2005 05:40:00 11.3 0.6 12.6 8.4 11.3 0.7 13 9.1 0.4 0 0.4 0.4 24 4 31 305 98 0 97 0 -2.5 0 -2.2 -2.7 05/10/2005 05:50:00 10.6 0.6 11.8 8.4 10.5 0.6 11.8 8.8 0.4 0 0.4 0.4 27 3 27 305 98 0 97 0 -2.5 0 -2.4 -2.7 05/10/2005 06:00:00 10.2 0.6 11.5 8.4 10.1 0.7 11.8 8.4 0.4 0 0.4 0.4 30 3 28 305 98 0 98 0 -2.4 0 -2.2 -2.7 05/10/2005 06:10:00 9.9 0.7 11.5 8 9.9 0.8 11.8 7.6 0.4 0 0.4 0.4 26 3 27 305 98 0 98 0 -2.4 0 -2.2 -2.7 05/10/2005 06:20:00 10.3 0.7 11.8 7.2 10.3 0.8 11.8 7.6 0.4 0 0.4 0.4 30 5 29 305 98 0 98 0 -2.4 0 -2 -2.7 05/10/2005 06:30:00 10.6 0.7 12.2 8.4 10.6 0.8 13 8 0.4 0 0.4 0.4 28 5 25 305 98 0 98 0 -2.5 0 -2.4 -2.7 05/10/2005 06:40:00 10.9 0.7 12.2 8.8 10.9 0.8 12.2 8.4 0.4 0 0.4 0.4 22 3 24 305 98 0 98 0 -2.6 0 -2.4 -2.7 05/10/2005 06:50:00 10.2 0.7 11.8 8.4 10 0.8 11.8 7.6 0.4 0 0.4 0.4 26 5 23 305 99 0 99 0 -2.5 0 -2 -2.7 05/10/2005 07:00:00 10.4 0.7 11.8 8.4 10.4 0.8 12.2 8.4 0.4 0 0.4 0.4 27 4 28 305 100 0 100 0 -2.5 0 -2.4 -2.7 05/10/2005 07:10:00 10.4 0.7 11.8 8.4 10.3 0.8 12.2 8 0.4 0 0.4 0.4 27 5 23 305 100 0 100 0 -2.5 0 -2.2 -2.7 05/10/2005 07:20:00 11 0.5 12.2 9.1 10.8 0.7 12.2 8.8 0.4 0 0.4 0.4 32 3 35 305 100 0 100 0 -2.3 0 -1.8 -2.4 05/10/2005 07:30:00 10.8 0.6 12.2 8.8 10.8 0.6 11.8 8.4 0.4 0 0.4 0.4 32 4 27 305 99 0 100 0 -2.3 0 -2.2 -2.4 05/10/2005 07:40:00 10.5 0.7 12.2 8.4 10.3 0.8 12.2 8 0.4 0 0.4 0.4 34 4 29 305 99 0 99 0 -2.4 0 -2.2 -2.4 05/10/2005 07:50:00 11.3 0.9 13 7.6 11.3 1 13 8 0.4 0 0.4 0.4 28 4 28 305 98 0 98 0 -2.5 0 -2.4 -2.7 05/10/2005 08:00:00 11.9 0.8 13.3 9.9 11.7 0.9 13.3 9.1 0.4 0 0.4 0.4 31 4 27 305 98 0 97 0 -2.5 0 -2 -2.7 05/10/2005 08:10:00 11.7 0.7 13.3 9.1 11.5 0.9 13.3 8.4 0.4 0 0.4 0.4 37 3 38 305 97 0 97 0 -2.6 0 -2.2 -2.7 05/10/2005 08:20:00 12.1 0.8 14.1 9.9 11.9 1 13.7 9.1 0.4 0 0.4 0.4 33 5 31 305 96 0 96 0 -2.6 0.1 -2.2 -2.7 05/10/2005 08:30:00 12.3 0.8 13.7 9.5 12.2 0.9 14.1 9.5 0.4 0 0.4 0.4 33 5 37 305 95 0 95 0 -2.6 0 -2.4 -2.7 05/10/2005 08:40:00 12.3 0.7 14.1 10.3 12.2 0.7 14.1 9.9 0.4 0 0.4 0.4 32 4 29 305 95 0 95 0 -2.5 0 -2.4 -2.7 05/10/2005 08:50:00 12.5 1 14.5 10.3 12.4 1.1 14.9 9.5 0.4 0 0.4 0.4 26 3 26 305 94 0 94 0 -2.6 0.1 -2.4 -2.7 05/10/2005 09:00:00 12.3 0.8 14.5 9.9 12.2 1 14.5 9.9 0.4 0 0.4 0.4 30 4 27 305 94 0 94 0 -2.6 0.1 -2.2 -2.7 05/10/2005 09:10:00 11.8 0.6 13.3 9.9 11.6 0.7 13.3 9.5 0.4 0 0.4 0.4 38 4 40 305 93 0 93 0 -2.3 0 -2.2 -2.4 05/10/2005 09:20:00 12.4 0.6 13.7 10.3 12.3 0.8 14.1 9.5 0.4 0 0.4 0.4 28 3 27 305 93 0 93 0 -2.4 0 -2.2 -2.7 05/10/2005 09:30:00 12.1 0.8 14.1 9.9 12 1 14.1 9.5 0.4 0 0.4 0.4 36 5 40 305 93 0 93 0 -2.4 0 -2.2 -2.7 05/10/2005 09:40:00 12.7 0.7 14.5 10.3 12.6 0.8 14.5 9.1 0.4 0 0.4 0.4 31 3 30 305 92 0 92 0 -2.6 0 -2.2 -2.7 05/10/2005 09:50:00 13 0.7 14.5 11.1 12.9 0.7 14.5 10.7 0.4 0 0.4 0.4 34 5 32 305 91 0 92 0 -2.4 0 -2.2 -2.7 05/10/2005 10:00:00 12.5 0.9 14.1 9.9 12.2 1 14.5 9.1 0.4 0 0.4 0.4 35 8 29 305 90 0 91 0 -2.3 0.2 -1.8 -2.7 05/10/2005 10:10:00 12.9 0.6 14.5 11.1 12.9 0.7 14.5 11.1 0.4 0 0.4 0.4 35 4 30 305 89 0 90 0 -2.7 0 -2.4 -2.9 05/10/2005 10:20:00 12.3 0.9 14.1 9.5 12.1 1 14.1 9.5 0.4 0 0.4 0.4 41 5 47 305 88 0 88 0 -2.3 0.1 -2 -2.7 05/10/2005 10:30:00 12.5 0.7 14.1 10.3 12.4 0.7 14.1 9.9 0.4 0 0.4 0.4 30 3 29 305 87 0 88 0 -2.5 0.2 -2 -2.7 05/10/2005 10:40:00 12.5 0.8 14.5 9.9 12.4 0.9 14.5 9.5 0.4 0 0.4 0.4 33 5 30 305 87 0 87 0 -2.3 0 -2.2 -2.4 05/10/2005 10:50:00 12.1 0.7 13.7 10.3 12 0.9 13.7 8.8 0.4 0 0.4 0.4 39 5 36 305 86 0 86 0 -2.3 0.1 -1.8 -2.7 05/10/2005 11:00:00 12.3 0.6 13.3 10.3 12.2 0.7 13.3 9.5 0.4 0 0.4 0.4 30 4 38 305 85 0 86 0 -2.5 0.1 -2 -2.7 05/10/2005 11:10:00 12.3 0.6 13.7 9.9 12.2 0.7 13.7 9.5 0.4 0 0.4 0.4 29 3 28 305 85 0 85 0 -2.4 0 -1.8 -2.7 05/10/2005 11:20:00 11.9 0.8 13.7 9.5 11.7 0.8 13.3 9.5 0.4 0 0.4 0.4 35 6 30 305 86 0 86 0 -2.2 0 -1.8 -2.4 05/10/2005 11:30:00 12.6 0.7 14.1 10.7 12.5 0.8 14.1 10.3 0.4 0 0.4 0.4 35 4 34 305 86 0 86 0 -2.2 0 -1.8 -2.4 05/10/2005 11:40:00 11.8 0.6 13.3 9.5 11.8 0.6 13 9.1 0.4 0 0.4 0.4 38 5 47 305 84 0 84 0 -2.2 0 -2 -2.4 05/10/2005 11:50:00 11.5 0.8 13 9.5 11.4 0.8 13.3 9.1 0.4 0 0.4 0.4 37 5 40 305 83 0 84 0 -2.3 0 -2 -2.7 05/10/2005 12:00:00 11.8 0.6 13.3 9.9 11.9 0.7 13.7 9.9 0.4 0 0.4 0.4 28 3 26 305 82 0 82 0 -2.4 0 -2.2 -2.7 05/10/2005 12:10:00 11 0.6 12.6 9.5 10.8 0.8 12.6 8.8 0.4 0 0.4 0.4 31 4 33 305 82 0 82 0 -2.2 0.1 -1.8 -2.4 05/10/2005 12:20:00 10.6 0.8 12.6 8.8 10.5 0.8 12.2 8.8 0.4 0 0.4 0.4 32 5 29 305 82 0 82 0 -2.2 0.1 -1.8 -2.4 05/10/2005 12:30:00 11.2 0.7 12.6 9.1 11.1 0.9 13 8.8 0.4 0 0.4 0.4 29 6 30 305 81 0 82 0 -2.2 0 -1.8 -2.4 05/10/2005 12:40:00 10.7 0.6 12.2 9.5 10.7 0.7 12.6 8.4 0.4 0 0.4 0.4 30 6 23 305 80 0 81 0 -2.3 0 -2 -2.4 05/10/2005 12:50:00 10.9 0.7 12.6 8.8 10.9 0.8 12.6 8.4 0.4 0 0.4 0.4 36 7 30 305 79 0 80 0 -2.2 0 -2 -2.4 05/10/2005 13:00:00 10.8 0.8 12.6 8.4 10.7 0.8 12.6 8.4 0.4 0 0.4 0.4 34 5 38 305 78 0 78 0 -2.2 0 -2 -2.4 05/10/2005 13:10:00 10.9 0.7 12.6 9.1 10.8 0.7 12.6 9.1 0.4 0 0.4 0.4 34 4 34 305 77 0 77 0 -2.1 0 -1.8 -2.4 05/10/2005 13:20:00 11.2 0.6 12.2 9.1 11 0.7 12.2 8.8 0.4 0 0.4 0.4 35 4 44 305 76 0 77 0 -2 0.2 -1.8 -2.2 05/10/2005 13:30:00 10.5 0.8 11.8 8 10.4 0.8 12.2 7.6 0.4 0 0.4 0.4 32 6 35 305 74 0 73 0 -2 0 -1.8 -2.2 05/10/2005 13:40:00 11.1 0.8 13 8.4 11 0.9 13 8.4 0.4 0 0.4 0.4 33 5 35 305 71 1 73 0 -2 0 -1.8 -2.2 05/10/2005 13:50:00 10.1 0.6 12.2 8 10 0.7 11.5 8 0.4 0 0.4 0.4 36 4 35 305 69 1 70 0 -1.8 0 -1.8 -2 05/10/2005 14:00:00 10.1 0.6 11.5 8.8 9.9 0.6 11.5 8.4 0.4 0 0.4 0.4 37 5 35 305 67 1 66 0 -1.6 0 -1.1 -1.8 05/10/2005 14:10:00 10.8 0.8 12.2 8.8 10.7 0.8 12.6 8 0.4 0 0.4 0.4 35 4 36 305 63 1 63 0 -1.6 0 -1.1 -1.8 05/10/2005 14:20:00 11.1 0.9 13 8.4 10.9 1 12.6 8 0.4 0 0.4 0.4 40 4 44 305 60 1 59 0 -1.6 0.1 -1.1 -1.8 05/10/2005 14:30:00 11.3 0.6 13.3 9.9 11.2 0.7 13 9.5 0.4 0 0.4 0.4 38 3 36 305 57 1 56 0 -1.4 0 -0.8 -1.8 05/10/2005 14:40:00 11.4 0.6 12.6 8.8 11.3 0.7 12.6 8.4 0.4 0 0.4 0.4 38 4 45 305 54 1 54 0 -1.2 0.1 -0.6 -1.3 05/10/2005 14:50:00 10.8 0.6 12.6 9.1 10.7 0.7 12.2 8.8 0.4 0 0.4 0.4 39 3 36 305 51 1 52 0 -1.2 0.1 -0.6 -1.5 05/10/2005 15:00:00 10.1 0.6 11.8 8.4 10.1 0.7 11.5 8 0.4 0 0.4 0.4 39 4 46 305 48 1 49 0 -1.3 0.1 -0.6 -1.8 05/10/2005 15:10:00 10.9 0.8 12.6 8.4 10.8 0.9 12.6 8.4 0.4 0 0.4 0.4 34 5 30 305 45 1 46 0 -1.5 0.2 -0.8 -2 05/10/2005 15:20:00 11 0.7 12.6 8.8 10.9 0.8 12.6 8 0.4 0 0.4 0.4 35 5 30 305 44 0 44 0 -1.6 0.1 -1.1 -2 05/10/2005 15:30:00 10 0.5 11.1 8.4 9.9 0.6 11.5 8 0.4 0 0.4 0.4 34 4 33 305 43 0 43 0 -1.6 0 -1.1 -1.8 05/10/2005 15:40:00 10.3 0.7 11.5 8.4 10.3 0.8 12.2 7.2 0.4 0 0.4 0.4 33 5 36 305 43 0 43 0 -1.5 0.2 -0.8 -1.8 05/10/2005 15:50:00 10.4 0.7 11.8 8.4 10.2 0.8 12.2 8 0.4 0 0.4 0.4 36 4 38 305 44 0 44 0 -1.2 0.1 -0.6 -1.5 05/10/2005 16:00:00 10 0.6 11.1 8 9.9 0.7 11.5 7.2 0.4 0 0.4 0.4 34 3 31 305 43 0 43 0 -1.2 0.1 -0.6 -1.5 05/10/2005 16:10:00 10.6 0.7 11.8 8.4 10.4 0.7 12.2 8.4 0.4 0 0.4 0.4 31 4 32 305 41 0 42 0 -1.2 0.1 -0.6 -1.5 05/10/2005 16:20:00 10.7 0.6 12.2 9.1 10.6 0.7 12.2 8.4 0.4 0 0.4 0.4 34 4 35 305 40 0 40 0 -1.4 0.2 -0.6 -1.8 05/10/2005 16:30:00 10.9 0.7 12.2 9.1 10.9 0.7 12.6 8.8 0.4 0 0.4 0.4 31 6 29 305 39 0 39 0 -1.5 0.1 -1.1 -1.8 05/10/2005 16:40:00 10.4 0.6 11.8 8.4 10.3 0.7 12.2 8 0.4 0 0.4 0.4 32 5 27 305 40 0 40 0 -1.5 0.1 -1.1 -1.8 05/10/2005 16:50:00 10.5 0.7 12.2 8.4 10.4 0.8 13 8 0.4 0 0.4 0.4 33 5 38 305 42 0 42 0 -1.5 0.1 -0.8 -1.8 05/10/2005 17:00:00 10.6 0.6 12.6 8.8 10.6 0.7 12.6 8.8 0.4 0 0.4 0.4 35 4 33 305 43 0 43 0 -1.5 0.1 -0.8 -1.8 05/10/2005 17:10:00 10.5 0.8 12.6 8.4 10.4 0.8 12.6 8 0.4 0 0.4 0.4 35 5 37 305 45 0 45 0 -1.5 0.1 -1.1 -1.8 05/10/2005 17:20:00 10.6 0.6 12.2 8 10.6 0.7 11.8 8.4 0.4 0 0.4 0.4 35 6 27 305 47 0 46 0 -1.7 0 -1.1 -1.8 05/10/2005 17:30:00 11.3 0.5 12.6 9.5 11.2 0.6 12.6 8.8 0.4 0 0.4 0.4 36 5 33 305 48 0 47 0 -1.9 0 -1.3 -2 05/10/2005 17:40:00 10.4 0.6 11.8 8.4 10.3 0.7 11.8 8.4 0.4 0 0.4 0.4 32 5 40 305 50 0 50 0 -1.8 0 -1.1 -2 05/10/2005 17:50:00 10.2 0.7 11.8 8 10.1 0.8 12.2 8.4 0.4 0 0.4 0.4 31 5 27 305 51 0 51 0 -1.7 0 -1.1 -1.8 05/10/2005 18:00:00 10 0.8 11.5 8 9.8 0.8 11.8 7.2 0.4 0 0.4 0.4 34 6 27 305 53 0 53 0 -1.8 0 -0.4 -2 05/10/2005 18:10:00 10.1 0.6 11.5 8.4 10.1 0.6 11.8 8.4 0.4 0 0.4 0.4 37 6 36 305 54 0 54 0 -1.8 0 -1.3 -2 05/10/2005 18:20:00 10.2 0.5 11.5 8.4 10.1 0.6 11.5 8 0.4 0 0.4 0.4 43 3 42 305 56 0 55 0 -1.9 0 -1.3 -2.2 05/10/2005 18:30:00 10.3 0.6 12.6 8.8 10.2 0.7 12.2 7.6 0.4 0 0.4 0.4 37 8 30 305 58 1 60 0 -1.9 0 -1.1 -2 05/10/2005 18:40:00 10.7 0.6 12.2 9.1 10.6 0.7 11.8 8.8 0.4 0 0.4 0.4 37 5 30 305 62 1 60 0 -2 0 -1.8 -2.2 05/10/2005 18:50:00 10.1 0.7 11.5 7.2 10 0.8 11.8 7.6 0.4 0 0.4 0.4 39 5 37 305 65 1 63 0 -1.9 0 -1.8 -2.2 05/10/2005 19:00:00 10.3 0.5 11.8 9.1 10.3 0.5 11.8 8.8 0.4 0 0.4 0.4 33 6 29 305 68 1 67 0 -1.9 0 -1.8 -2 05/10/2005 19:10:00 10.7 0.8 12.2 8.4 10.6 0.8 12.6 8 0.4 0 0.4 0.4 30 5 27 305 71 1 72 0 -1.9 0.1 -1.5 -2.2 05/10/2005 19:20:00 11 0.6 12.6 9.1 10.9 0.6 12.6 8.8 0.4 0 0.4 0.4 38 3 36 305 73 0 74 0 -2 0 -1.5 -2.2 05/10/2005 19:30:00 10.8 0.7 12.2 8.8 10.7 0.8 12.2 8.8 0.4 0 0.4 0.4 39 5 40 305 75 0 76 0 -2 0.1 -1.5 -2.2 05/10/2005 19:40:00 11 0.8 12.6 9.1 10.9 0.8 13 8.4 0.4 0 0.4 0.4 38 5 37 305 77 0 77 0 -2 0 -1.5 -2.2 05/10/2005 19:50:00 11.3 0.9 13 8.8 11.1 0.9 13 8.8 0.4 0 0.4 0.4 36 5 27 305 78 0 78 0 -1.9 0 -1.5 -2 05/10/2005 20:00:00 10.7 0.7 12.2 8.4 10.6 0.8 12.2 8.8 0.4 0 0.4 0.4 35 4 31 305 80 0 80 0 -1.8 0 -1.3 -2 05/10/2005 20:10:00 10 0.7 11.5 8 9.9 0.7 11.8 7.6 0.4 0 0.4 0.4 38 4 37 305 81 0 82 0 -1.8 0 -1.5 -2 05/10/2005 20:20:00 10.7 0.7 12.2 9.1 10.6 0.8 12.6 8 0.4 0 0.4 0.4 31 5 27 305 83 0 83 0 -0.8 2.4 11 -2 05/10/2005 20:30:00 10.3 0.7 11.8 8.8 10.3 0.8 12.2 8.4 0.4 0 0.4 0.4 36 3 35 305 83 0 83 0 1.2 5.9 24.3 -2 05/10/2005 20:40:00 10.4 0.7 11.8 8.8 10.3 0.7 11.8 8.8 0.4 0 0.4 0.4 36 3 38 305 82 0 83 0 -1.4 0.7 6.9 -1.8 05/10/2005 20:50:00 9.8 0.6 11.1 8.4 9.8 0.7 11.1 7.6 0.4 0 0.4 0.4 36 3 35 305 82 1 84 0 -1.2 0 -1.1 -1.5 05/10/2005 21:00:00 10.3 0.5 11.5 8.8 10.2 0.6 11.5 8.4 0.4 0 0.4 0.4 36 3 36 305 79 1 81 0 -1.1 0 -0.6 -1.3 05/10/2005 21:10:00 10.5 0.5 11.5 9.1 10.4 0.5 11.8 8.8 0.4 0 0.4 0.4 37 3 38 305 75 1 75 0 -0.7 2.1 11 -1.3 05/10/2005 21:20:00 11.2 0.5 13 9.5 11.1 0.6 12.6 9.1 0.4 0 0.4 0.4 40 2 40 305 73 0 72 0 9.7 6.7 23.4 -1.5 05/10/2005 21:30:00 10.5 0.6 11.8 9.1 10.6 0.6 12.2 8.8 0.4 0 0.4 0.4 38 4 33 305 72 0 72 0 -1.4 0.2 1 -1.5 05/10/2005 21:40:00 11 0.5 12.2 9.5 10.9 0.6 11.8 9.1 0.4 0 0.4 0.4 40 3 39 305 73 0 73 0 -1.5 0.1 0.6 -1.8 05/10/2005 21:50:00 11 0.5 12.2 9.1 11 0.6 12.2 9.1 0.4 0 0.4 0.4 40 3 43 305 74 0 73 0 -1.5 0.3 2.7 -1.8 05/10/2005 22:00:00 10.2 0.7 11.8 8 10.1 0.8 11.8 8 0.4 0 0.4 0.4 42 4 40 305 75 0 75 0 -1.3 0.9 5.9 -1.8 05/10/2005 22:10:00 10.4 0.6 11.8 8.4 10.3 0.6 11.8 8.8 0.4 0 0.4 0.4 45 3 42 305 76 0 76 0 -1.6 0 -1.3 -1.8 05/10/2005 22:20:00 10.9 0.8 13 8.8 10.8 0.9 13 8.4 0.4 0 0.4 0.4 36 6 32 305 78 0 78 0 -1.6 0 -1.5 -1.8 05/10/2005 22:30:00 10.4 0.6 11.8 9.1 10.3 0.7 11.8 8 0.4 0 0.4 0.4 38 5 28 305 79 0 79 0 -1.6 0 -1.5 -1.8 05/10/2005 22:40:00 10.7 0.7 12.6 8.4 10.5 0.7 12.2 8.4 0.4 0 0.4 0.4 39 4 41 305 80 0 80 0 -1.7 0 -1.5 -1.8 05/10/2005 22:50:00 10.1 0.9 11.8 8 9.9 0.9 11.5 8 0.4 0 0.4 0.4 39 5 38 305 81 0 81 0 -1.7 0 -1.3 -1.8 05/10/2005 23:00:00 10.4 0.6 12.6 9.1 10.3 0.7 12.2 8.4 0.4 0 0.4 0.4 41 4 42 305 82 0 83 0 -1.7 0 -1.5 -1.8 05/10/2005 23:10:00 10.9 0.7 12.2 8.8 10.8 0.7 12.2 7.6 0.4 0 0.4 0.4 41 3 42 305 83 0 84 0 -1.8 0 -1.8 -2 05/10/2005 23:20:00 10.4 1.1 13 8 10.4 1.2 13 8 0.4 0 0.4 0.4 39 4 36 305 84 0 84 0 -1.8 0 -1.8 -2 05/10/2005 23:30:00 10.8 0.7 12.6 8.4 10.6 0.8 12.2 8.4 0.4 0 0.4 0.4 44 3 46 305 86 0 85 0 -1.8 0 -1.8 -2 05/10/2005 23:40:00 11.5 0.6 13 9.5 11.4 0.8 13.3 9.1 0.4 0 0.4 0.4 44 4 48 305 87 0 87 0 -1.9 0 -1.5 -2 05/10/2005 23:50:00 11.5 0.7 13 9.5 11.5 0.8 13 9.1 0.4 0 0.4 0.4 41 3 38 305 87 0 87 0 -2 0 -1.5 -2.2 05/11/2005 00:00:00 11.3 0.5 12.6 9.5 11.1 0.7 12.6 9.1 0.4 0 0.4 0.4 47 3 43 305 87 0 87 0 -1.9 0 -1.3 -2 05/11/2005 00:10:00 11.2 0.7 12.6 9.1 11 0.8 12.6 8.8 0.4 0 0.4 0.4 42 2 44 305 88 0 88 0 -2 0 -1.8 -2 05/11/2005 00:20:00 10.1 0.6 11.5 8.8 10.1 0.6 11.8 8 0.4 0 0.4 0.4 45 3 48 305 89 0 88 0 -1.9 0 -1.8 -2 05/11/2005 00:30:00 9.8 0.5 11.1 8.4 9.6 0.6 11.5 7.6 0.4 0 0.4 0.4 44 3 41 305 89 0 89 0 -1.9 0 -1.8 -2 05/11/2005 00:40:00 9.8 0.7 11.8 8.4 9.7 0.8 11.5 8 0.4 0 0.4 0.4 43 3 42 305 90 0 90 0 -1.8 0 -1.8 -2 05/11/2005 00:50:00 11.2 0.8 13 9.1 11.1 0.8 13 9.5 0.4 0 0.4 0.4 36 4 35 305 91 0 91 0 -1.7 0 -1.8 -2 05/11/2005 01:00:00 12.1 0.5 13.3 10.3 12 0.5 13.3 10.3 0.4 0 0.4 0.4 37 3 43 305 91 0 91 0 -1.9 0.1 -1.8 -2 05/11/2005 01:10:00 12.2 0.5 13.3 10.3 12.1 0.6 13.3 9.9 0.4 0 0.4 0.4 41 5 46 305 90 0 91 0 -2.1 0 -2 -2.2 05/11/2005 01:20:00 12 0.7 13.7 10.3 11.9 0.8 13.7 10.3 0.4 0 0.4 0.4 48 5 49 305 90 0 90 0 -2.2 0 -1.8 -2.4 05/11/2005 01:30:00 11.7 0.6 13.3 10.3 11.6 0.6 13.7 9.9 0.4 0 0.4 0.4 45 5 50 305 91 0 91 0 -2.2 0 -2 -2.4 05/11/2005 01:40:00 11.8 0.5 13.7 10.3 11.6 0.6 13.3 9.9 0.4 0 0.4 0.4 41 3 45 305 91 0 92 0 -2.1 0 -1.8 -2.2 05/11/2005 01:50:00 13 0.6 14.5 11.1 12.9 0.7 14.5 10.7 0.4 0 0.4 0.4 44 3 44 305 92 0 92 0 -2.2 0 -2 -2.4 05/11/2005 02:00:00 12.8 0.6 14.1 10.7 12.6 0.8 14.1 10.3 0.4 0 0.4 0.4 44 3 46 305 92 0 92 0 -2.3 0 -2 -2.4 05/11/2005 02:10:00 12.5 0.6 13.7 10.3 12.3 0.7 13.7 9.9 0.4 0 0.4 0.4 42 3 37 305 93 0 93 0 -2.3 0 -2.2 -2.4 05/11/2005 02:20:00 12.5 0.7 13.7 10.3 12.3 0.8 13.7 9.5 0.4 0 0.4 0.4 43 3 43 305 94 0 94 0 -2.3 0 -1.8 -2.4 05/11/2005 02:30:00 12.5 0.6 13.7 10.3 12.4 0.6 13.7 10.3 0.4 0 0.4 0.4 39 3 46 305 94 0 94 0 -2.2 0 -2 -2.4 05/11/2005 02:40:00 12.7 0.6 14.1 10.7 12.5 0.7 13.7 9.9 0.4 0 0.4 0.4 42 3 42 305 96 0 95 0 -2.2 0 -2 -2.4 05/11/2005 02:50:00 13.6 0.6 14.9 11.8 13.5 0.7 14.9 10.7 0.4 0 0.4 0.4 42 4 43 305 96 0 96 0 -2.4 0 -2.2 -2.7 05/11/2005 03:00:00 13.6 0.8 15.3 11.5 13.4 1 15.3 10.7 0.4 0 0.4 0.4 36 4 39 305 97 0 97 0 -2.3 0 -2 -2.4 05/11/2005 03:10:00 13.1 0.7 14.5 11.1 12.9 0.8 14.5 11.1 0.4 0 0.4 0.4 36 5 28 305 98 0 98 0 -2.3 0 -2.2 -2.4 05/11/2005 03:20:00 12.5 0.6 14.1 10.3 12.4 0.8 13.7 9.9 0.4 0 0.4 0.4 42 3 44 305 99 0 99 0 -2.3 0 -2.2 -2.7 05/11/2005 03:30:00 13 0.7 14.5 11.1 12.8 0.8 14.1 10.3 0.4 0 0.4 0.4 42 3 40 305 99 0 99 0 -2.4 0 -2.2 -2.7 05/11/2005 03:40:00 12.3 0.7 14.1 9.9 12.2 0.8 14.1 9.1 0.4 0 0.4 0.4 43 4 42 305 100 0 100 0 -2.4 0 -2.2 -2.7 05/11/2005 03:50:00 11.5 0.8 13 9.1 11.2 1 13.3 8.4 0.4 0 0.4 0.4 46 3 47 305 101 0 100 0 -2.5 0 -2.2 -2.7 05/11/2005 04:00:00 11.8 0.8 13.3 9.1 11.7 0.8 13.3 9.5 0.4 0 0.4 0.4 40 5 40 305 102 0 102 0 -2.4 0 -1.8 -2.7 05/11/2005 04:10:00 12.2 0.7 13.7 10.3 12.1 0.7 13.7 9.9 0.4 0 0.4 0.4 39 3 44 305 102 0 102 0 -2.4 0 -2 -2.4 05/11/2005 04:20:00 12.6 0.8 13.7 9.1 12.5 0.8 14.1 8.8 0.4 0 0.4 0.4 40 4 42 305 102 0 102 0 -2.5 0 -2.4 -2.7 05/11/2005 04:30:00 12.8 0.7 14.1 11.1 12.5 0.9 14.5 10.3 0.4 0 0.4 0.4 41 3 40 305 102 0 103 0 -2.4 0 -2 -2.7 05/11/2005 04:40:00 13 0.8 14.9 11.1 12.9 0.9 15.3 10.7 0.4 0 0.4 0.4 39 4 39 305 102 0 103 0 -2.3 0 -2.2 -2.4 05/11/2005 04:50:00 13.2 0.7 14.9 11.1 13 0.8 14.9 10.3 0.4 0 0.4 0.4 41 4 40 305 102 0 102 0 -2.4 0 -2.2 -2.4 05/11/2005 05:00:00 13.2 0.8 15.6 11.5 13.1 0.8 15.3 11.5 0.4 0 0.4 0.4 43 3 47 305 102 0 102 0 -2.3 0 -2.2 -2.4 05/11/2005 05:10:00 13.9 0.5 15.3 12.2 13.7 0.7 15.3 11.1 0.4 0 0.4 0.4 44 3 39 305 102 0 102 0 -2.4 0 -2.2 -2.7 05/11/2005 05:20:00 12.8 0.9 15.3 10.3 12.5 1 15.3 9.5 0.4 0 0.4 0.4 45 3 42 305 102 0 102 0 -2.4 0 -2.2 -2.7 05/11/2005 05:30:00 12.8 0.6 14.5 10.7 12.6 0.8 14.5 9.9 0.4 0 0.4 0.4 42 4 41 305 102 0 102 0 -2.3 0 -2 -2.4 05/11/2005 05:40:00 12.7 0.6 14.1 10.7 12.6 0.7 14.5 10.3 0.4 0 0.4 0.4 39 4 44 305 102 0 102 0 -2.3 0 -2.2 -2.4 05/11/2005 05:50:00 12.9 0.6 14.5 10.7 12.6 0.8 14.5 10.3 0.4 0 0.4 0.4 43 4 42 305 102 0 102 0 -2.3 0 -2.2 -2.4 05/11/2005 06:00:00 12 0.7 13.3 9.9 11.8 0.8 13.3 9.5 0.4 0 0.4 0.4 41 4 37 305 102 0 101 0 -2.2 0 -2 -2.4 05/11/2005 06:10:00 12.3 0.7 13.7 10.3 12.2 0.8 14.1 9.9 0.4 0 0.4 0.4 38 4 34 305 102 0 103 0 -2.2 0 -2 -2.4 05/11/2005 06:20:00 12.2 0.8 13.7 10.3 12.1 0.9 14.1 9.9 0.4 0 0.4 0.4 36 4 32 305 102 0 103 0 -2.2 0 -2 -2.4 05/11/2005 06:30:00 11.3 0.6 12.6 9.1 11.1 0.8 13 8.8 0.4 0 0.4 0.4 39 5 31 305 103 0 103 0 -2.2 0 -1.8 -2.2 05/11/2005 06:40:00 11.5 0.6 13.3 9.5 11.4 0.6 13.3 9.5 0.4 0 0.4 0.4 40 5 40 305 103 0 103 0 -2.2 0 -2 -2.2 05/11/2005 06:50:00 12.2 0.6 13.3 10.3 12.1 0.6 13.3 9.9 0.4 0 0.4 0.4 38 5 40 305 104 0 103 0 -2.2 0 -1.8 -2.4 05/11/2005 07:00:00 11.5 0.7 13 9.1 11.5 0.8 13 9.1 0.4 0 0.4 0.4 29 4 24 305 104 0 104 0 -2.3 0 -2.2 -2.4 05/11/2005 07:10:00 11 0.8 12.6 8.8 10.9 0.9 12.6 8.8 0.4 0 0.4 0.4 40 6 46 305 105 0 105 0 -2.3 0 -2 -2.7 05/11/2005 07:20:00 11.9 0.6 13.3 9.9 11.8 0.7 13.7 9.9 0.4 0 0.4 0.4 35 4 37 305 105 0 105 0 -2.3 0 -2.2 -2.4 05/11/2005 07:30:00 12.1 0.6 13.3 10.3 12.1 0.7 13.3 9.9 0.4 0 0.4 0.4 38 6 32 305 105 0 106 0 -2.3 0 -2 -2.4 05/11/2005 07:40:00 12 0.7 13.3 9.9 11.8 0.7 13.3 9.5 0.4 0 0.4 0.4 36 6 43 305 105 0 106 0 -2.3 0 -2.2 -2.4 05/11/2005 07:50:00 12.2 0.7 13.7 9.5 12.1 0.9 13.7 9.5 0.4 0 0.4 0.4 41 5 40 305 106 0 106 0 -2.3 0 -2.2 -2.4 05/11/2005 08:00:00 11.7 0.7 13.3 9.9 11.6 0.8 13.3 9.5 0.4 0 0.4 0.4 41 3 42 305 106 0 106 0 -2.2 0 -1.8 -2.4 05/11/2005 08:10:00 12 0.8 14.1 9.9 11.9 0.8 13.7 9.9 0.4 0 0.4 0.4 41 5 43 305 107 0 107 0 -2.2 0 -2 -2.4 05/11/2005 08:20:00 12 0.8 14.1 9.1 11.9 1 13.7 8.4 0.4 0 0.4 0.4 39 4 41 305 106 0 106 0 -2.2 0 -2 -2.4 05/11/2005 08:30:00 11.6 0.8 13.3 9.5 11.4 0.8 13.3 8.8 0.4 0 0.4 0.4 46 4 41 305 105 0 107 0 -2.3 0 -2.2 -2.4 05/11/2005 08:40:00 11.3 0.8 13 9.1 11.1 1 13.3 8.8 0.4 0 0.4 0.4 40 6 39 305 104 0 104 0 -2.2 0 -2 -2.4 05/11/2005 08:50:00 11.9 0.6 13.3 10.3 11.7 0.8 13.3 9.5 0.4 0 0.4 0.4 40 5 44 305 104 0 103 0 -2.2 0 -2 -2.4 05/11/2005 09:00:00 11.8 0.9 14.1 9.5 11.6 1 13.7 8.8 0.4 0 0.4 0.4 40 4 38 305 103 0 103 0 -2.2 0 -2 -2.4 05/11/2005 09:10:00 11.9 1 13.7 9.1 11.6 1 13.7 8.8 0.4 0 0.4 0.4 42 4 44 305 102 0 103 0 -2.2 0 -1.8 -2.4 05/11/2005 09:20:00 11.2 0.9 13.3 8.4 11 0.9 13 8 0.4 0 0.4 0.4 44 4 42 305 101 0 101 0 -2.4 0 -2.2 -2.7 05/11/2005 09:30:00 11.2 0.9 13.3 8.8 11 1 12.6 7.6 0.4 0 0.4 0.4 38 5 41 305 100 0 100 0 -2.3 0 -1.8 -2.7 05/11/2005 09:40:00 11.3 0.8 13.3 8.8 11.2 0.8 13 9.1 0.4 0 0.4 0.4 39 5 34 305 100 0 100 0 -2.2 0 -2 -2.4 05/11/2005 09:50:00 11.9 0.6 13.3 10.3 11.8 0.8 13.3 9.1 0.4 0 0.4 0.4 41 7 32 305 100 0 100 0 -2.2 0 -2 -2.4 05/11/2005 10:00:00 11.3 0.8 13 9.5 11.2 0.8 13 8.8 0.4 0 0.4 0.4 38 7 27 305 100 0 100 0 -2.2 0 -2 -2.4 05/11/2005 10:10:00 11.6 0.7 13 9.1 11.5 0.8 13 9.1 0.4 0 0.4 0.4 40 5 36 305 100 0 100 0 -2.3 0 -2 -2.4 05/11/2005 10:20:00 11.4 0.7 13 9.5 11.3 0.8 13 9.1 0.4 0 0.4 0.4 41 3 46 305 99 0 99 0 -2.2 0 -2 -2.4 05/11/2005 10:30:00 11.7 0.7 13.3 9.1 11.6 0.8 13.3 9.1 0.4 0 0.4 0.4 39 4 41 305 99 0 99 0 -2.2 0 -2 -2.4 05/11/2005 10:40:00 12.3 0.6 13.7 10.3 12.2 0.7 13.3 9.9 0.4 0 0.4 0.4 39 3 40 305 99 0 99 0 -2.2 0 -1.8 -2.4 05/11/2005 10:50:00 11.6 0.9 13.3 9.5 11.5 1 13.3 9.5 0.4 0 0.4 0.4 40 4 39 305 98 0 98 0 -2.1 0 -1.8 -2.2 05/11/2005 11:00:00 12.1 0.8 13.7 9.5 12 0.9 13.7 9.1 0.4 0 0.4 0.4 39 5 42 305 97 0 97 0 -2 0 -2 -2.2 05/11/2005 11:10:00 12.1 0.7 13.7 9.9 12 0.7 14.1 9.9 0.4 0 0.4 0.4 39 5 38 305 96 0 95 0 -1.9 0 -1.8 -2 05/11/2005 11:20:00 12.3 0.8 14.9 10.3 12.1 0.8 14.9 9.5 0.4 0 0.4 0.4 38 4 38 305 95 0 94 0 -1.9 0 -1.8 -2 05/11/2005 11:30:00 12.4 0.6 13.7 10.3 12.2 0.7 13.7 10.3 0.4 0 0.4 0.4 35 4 29 305 93 1 92 0 -1.8 0 -1.8 -2 05/11/2005 11:40:00 12.8 0.5 13.7 11.1 12.7 0.5 14.1 11.1 0.4 0 0.4 0.4 31 3 34 305 91 0 92 0 -1.8 0.1 -1.3 -2 05/11/2005 11:50:00 12.2 0.6 13.3 10.7 12 0.7 13.3 9.9 0.4 0 0.4 0.4 33 3 33 305 90 0 91 0 -1.7 0 -1.3 -2 05/11/2005 12:00:00 11.7 0.8 13.3 9.1 11.6 0.9 13.7 9.1 0.4 0 0.4 0.4 37 4 36 305 88 0 87 0 -1.4 1.3 13.2 -1.8 05/11/2005 12:10:00 12.7 0.7 13.7 10.7 12.6 0.8 14.1 10.3 0.4 0 0.4 0.4 39 6 32 305 86 1 87 0 -1.7 1.1 18.4 -2 05/11/2005 12:20:00 12.5 0.5 13.7 11.1 12.3 0.6 13.7 10.3 0.4 0 0.4 0.4 38 3 36 305 84 0 85 0 6.5 16 45.2 -1.8 05/11/2005 12:30:00 12.3 0.5 13.7 10.3 12.3 0.6 13.7 10.3 0.4 0 0.4 0.4 37 5 34 305 83 0 82 0 20.9 7 35.6 -1.8 05/11/2005 12:40:00 12.5 0.7 13.7 10.7 12.3 0.8 13.7 10.3 0.4 0 0.4 0.4 33 3 34 305 82 0 82 0 9.9 9.9 29.8 -1.8 05/11/2005 12:50:00 12.1 0.6 13.3 9.9 12 0.8 13.3 9.5 0.4 0 0.4 0.4 36 4 33 305 80 0 81 0 16.6 12.3 31 -1.5 05/11/2005 13:00:00 12.5 0.7 13.7 10.3 12.5 0.8 14.1 9.9 0.4 0 0.4 0.4 38 3 41 305 79 1 79 0 15.9 8.7 37.6 -1.5 05/11/2005 13:10:00 12.3 0.5 13.7 10.7 12.3 0.6 13.7 9.9 0.4 0 0.4 0.4 40 3 38 305 76 1 77 0 4.4 6.7 19.9 -1.5 05/11/2005 13:20:00 12.2 0.8 14.1 10.3 12.1 0.8 14.1 9.5 0.4 0 0.4 0.4 36 4 32 305 74 1 73 0 -1.4 0 -1.1 -1.8 05/11/2005 13:30:00 11.9 0.7 13.7 10.3 11.7 0.8 13.3 9.1 0.4 0 0.4 0.4 34 3 33 305 71 1 72 0 0.8 3.2 8.7 -1.8 05/11/2005 13:40:00 11.8 0.7 13.3 9.9 11.6 0.8 13.3 9.5 0.4 0 0.4 0.4 36 5 26 305 69 0 69 0 1.2 3.4 13.2 -1.8 05/11/2005 13:50:00 12.1 0.8 14.5 10.3 12 0.9 14.1 9.5 0.4 0 0.4 0.4 35 5 40 305 67 0 67 0 -0.4 1.5 5.9 -1.8 05/11/2005 14:00:00 12.4 0.8 14.5 10.3 12.3 0.9 14.5 9.9 0.4 0 0.4 0.4 41 4 45 305 66 0 67 0 0.3 2.9 13.4 -1.5 05/11/2005 14:10:00 11.9 0.6 13.3 10.3 11.8 0.8 13.7 9.9 0.4 0 0.4 0.4 38 3 39 305 66 0 65 0 4.7 4.2 14 -1.3 05/11/2005 14:20:00 12.1 0.5 13.3 10.3 12 0.7 13.3 9.5 0.4 0 0.4 0.4 40 4 35 305 63 1 64 0 5.6 2.6 11.3 -1.3 05/11/2005 14:30:00 12 0.6 13.3 9.9 11.9 0.8 13.3 9.1 0.4 0 0.4 0.4 37 4 37 305 60 1 62 0 2.1 2.5 8.2 -1.3 05/11/2005 14:40:00 11.2 0.6 12.6 8.8 11.1 0.8 12.6 8.4 0.4 0 0.4 0.4 35 4 33 305 58 0 59 0 3.7 3.4 12.4 -1.3 05/11/2005 14:50:00 11.7 0.8 13.7 9.5 11.6 0.9 13.7 9.1 0.4 0 0.4 0.4 32 3 31 305 56 0 55 0 4 2.7 12.1 -1.3 05/11/2005 15:00:00 11.7 0.6 13.3 10.3 11.5 0.7 13.7 9.5 0.4 0 0.4 0.4 36 5 32 305 54 0 53 0 1.2 2.3 8.4 -1.3 05/11/2005 15:10:00 13 0.6 14.5 10.3 13 0.8 14.5 9.5 0.4 0 0.4 0.4 39 3 39 305 52 0 52 0 -0.8 1.1 4.7 -1.8 05/11/2005 15:20:00 12.7 0.8 14.1 10.3 12.6 0.8 14.1 10.3 0.4 0 0.4 0.4 44 5 44 305 51 0 52 0 0.3 2.7 8.9 -1.8 05/11/2005 15:30:00 13 0.7 14.9 11.5 12.9 0.9 14.9 11.1 0.4 0 0.4 0.4 40 3 39 305 50 0 50 0 -1.2 0 -0.4 -1.3 05/11/2005 15:40:00 12.9 0.7 14.5 10.3 12.7 0.8 14.5 9.9 0.4 0 0.4 0.4 41 4 38 305 49 0 49 0 -1 0.2 1 -1.1 05/11/2005 15:50:00 13.1 0.7 14.5 10.7 12.9 0.8 14.5 10.3 0.4 0 0.4 0.4 42 3 44 305 46 1 47 0 -0.9 0.2 0.1 -1.1 05/11/2005 16:00:00 12.7 0.6 13.7 10.7 12.6 0.8 14.1 9.9 0.4 0 0.4 0.4 38 4 37 305 43 1 44 0 -1 0.1 -0.4 -1.3 05/11/2005 16:10:00 12.9 0.5 14.1 11.1 12.8 0.7 14.1 10.7 0.4 0 0.4 0.4 41 4 43 305 42 0 42 0 -1.1 0.1 -0.4 -1.3 05/11/2005 16:20:00 12.9 0.7 14.5 11.1 12.8 0.8 14.5 9.9 0.4 0 0.4 0.4 37 4 40 305 42 0 42 0 -1.3 0.1 -0.6 -1.5 05/11/2005 16:30:00 12.5 0.6 14.1 10.7 12.4 0.7 14.1 9.9 0.4 0 0.4 0.4 41 5 40 305 42 0 42 0 -1.3 0.4 1.5 -1.8 05/11/2005 16:40:00 12.7 0.7 14.5 10.3 12.5 0.9 14.5 9.5 0.4 0 0.4 0.4 42 4 48 305 44 0 44 0 -0.7 2.8 14.5 -1.8 05/11/2005 16:50:00 13.2 0.8 14.9 10.7 13 0.9 14.9 10.7 0.4 0 0.4 0.4 43 4 41 305 45 0 45 0 7.2 3.8 17.6 -1.3 05/11/2005 17:00:00 13.1 0.8 15.6 10.7 12.9 1 14.9 9.5 0.4 0 0.4 0.4 42 4 43 305 45 0 45 0 9.3 4.4 17.6 -1.8 05/11/2005 17:10:00 13.3 0.6 14.5 11.5 13.2 0.6 14.9 11.1 0.4 0 0.4 0.4 38 3 32 305 46 1 45 0 12.4 2.9 19.6 -1.3 05/11/2005 17:20:00 13.3 0.7 15.3 11.5 13.2 0.7 14.9 10.7 0.4 0 0.4 0.4 39 3 39 305 47 0 47 0 9.1 3.1 19 -1.3 05/11/2005 17:30:00 12.7 0.7 14.1 10.7 12.5 0.8 14.1 10.3 0.4 0 0.4 0.4 40 4 42 305 48 0 48 0 5.2 2.4 11.3 -1.3 05/11/2005 17:40:00 13.6 0.9 15.3 11.1 13.4 1.1 15.3 10.3 0.4 0 0.4 0.4 41 4 38 305 48 0 48 0 5.8 2.5 12.9 -1.3 05/11/2005 17:50:00 14.1 0.6 15.3 12.2 13.9 0.8 15.6 11.1 0.4 0 0.4 0.4 47 3 46 305 47 0 47 0 5 2.2 10.5 -1.3 05/11/2005 18:00:00 14.2 0.6 16.1 12.2 13.9 0.8 15.6 11.5 0.4 0 0.4 0.4 46 4 46 305 48 0 48 0 4.7 2.3 11.3 -1.5 05/11/2005 18:10:00 14 0.5 15.3 12.2 13.8 0.6 15.3 11.8 0.4 0 0.4 0.4 47 3 45 305 48 0 48 0 8.4 2.8 14 -1.3 05/11/2005 18:20:00 13.8 0.6 15.3 12.2 13.5 0.8 14.9 11.1 0.4 0 0.4 0.4 46 3 48 305 47 0 48 0 -0.8 1 3.7 -1.5 05/11/2005 18:30:00 13.4 0.6 14.9 11.5 13.3 0.7 14.9 11.1 0.4 0 0.4 0.4 44 3 42 305 47 0 47 0 0 1.9 6.4 -1.3 05/11/2005 18:40:00 13.4 0.6 14.5 11.5 13.2 0.8 14.5 11.1 0.4 0 0.4 0.4 45 3 45 305 46 0 46 0 3.9 2.9 9.7 -1.5 05/11/2005 18:50:00 13.3 0.5 14.5 11.5 13.2 0.7 14.5 10.3 0.4 0 0.4 0.4 45 3 45 305 46 0 46 0 0.8 5 16.2 -1.8 05/11/2005 19:00:00 13.1 0.5 14.1 11.8 12.9 0.6 14.5 11.1 0.4 0 0.4 0.4 47 3 46 305 47 0 47 0 7.2 4.2 14.8 -1.8 05/11/2005 19:10:00 13.1 0.5 14.5 11.1 13 0.7 14.5 11.1 0.4 0 0.4 0.4 42 4 36 305 49 0 49 0 1.3 2.1 5.4 -1.8 05/11/2005 19:20:00 12.4 0.6 13.7 9.9 12.2 0.7 13.7 9.9 0.4 0 0.4 0.4 42 4 48 305 50 0 51 0 2 1.8 6.1 -1.8 05/11/2005 19:30:00 12.5 0.6 13.7 10.7 12.5 0.6 13.7 10.3 0.4 0 0.4 0.4 38 5 44 305 51 0 52 0 -1.1 0.8 1.5 -1.8 05/11/2005 19:40:00 11.7 0.7 13.3 9.9 11.6 0.9 13.3 9.1 0.4 0 0.4 0.4 39 6 33 305 52 0 52 0 -0.6 0.8 1.3 -1.8 05/11/2005 19:50:00 11.5 0.7 13 9.1 11.3 0.8 13.3 9.1 0.4 0 0.4 0.4 40 4 38 305 54 0 54 0 -1.6 0.5 2.2 -2 05/11/2005 20:00:00 12.3 0.6 13.7 9.9 12.2 0.7 13.7 9.9 0.4 0 0.4 0.4 42 5 54 305 55 0 55 0 0.6 2.2 4.4 -2 05/11/2005 20:10:00 11.5 0.6 12.6 9.9 11.3 0.7 13 9.1 0.4 0 0.4 0.4 41 4 33 305 57 0 56 0 1.3 1.6 5.4 -2 05/11/2005 20:20:00 11.8 0.9 14.1 9.5 11.6 0.9 13.7 8.8 0.4 0 0.4 0.4 40 6 38 305 58 1 59 0 0.7 1.8 5.9 -2.2 05/11/2005 20:30:00 11.9 0.5 13 10.7 11.8 0.6 13 9.9 0.4 0 0.4 0.4 31 3 34 305 60 0 60 0 -1.8 0.4 0.3 -2 05/11/2005 20:40:00 11.2 0.6 13 9.1 11.1 0.7 12.6 8.8 0.4 0 0.4 0.4 35 5 32 305 62 0 61 0 5.5 6.7 18.4 -2 05/11/2005 20:50:00 11.4 0.5 13 9.5 11.4 0.6 12.6 9.1 0.4 0 0.4 0.4 37 4 36 305 63 0 63 0 -1.4 1.4 5.9 -2 05/11/2005 21:00:00 11.4 0.5 12.6 9.9 11.3 0.6 12.6 9.5 0.4 0 0.4 0.4 38 7 45 305 64 0 64 0 -1.6 0.6 1 -2 05/11/2005 21:10:00 11.9 0.7 13.3 9.9 11.8 0.8 13.3 9.9 0.4 0 0.4 0.4 32 3 34 305 65 0 65 0 2.2 1.2 4.7 -2 05/11/2005 21:20:00 12 0.5 13 9.9 12 0.6 13.3 9.5 0.4 0 0.4 0.4 34 4 40 305 66 0 66 0 -0.2 1.1 2.2 -2 05/11/2005 21:30:00 11.3 0.7 13 8.8 11.2 0.8 12.6 8.8 0.4 0 0.4 0.4 34 4 33 305 67 0 67 0 -0.7 1 1.3 -2.2 05/11/2005 21:40:00 12.2 0.7 13.7 10.3 12.1 0.7 13.7 9.9 0.4 0 0.4 0.4 38 4 36 305 69 1 70 0 -2.2 0.1 -1.1 -2.4 05/11/2005 21:50:00 12.6 0.6 14.1 10.7 12.4 0.7 14.1 10.7 0.4 0 0.4 0.4 35 4 34 305 72 0 71 0 -2.2 0 -1.8 -2.4 05/11/2005 22:00:00 12.1 0.9 13.7 9.5 11.9 1 13.7 9.5 0.4 0 0.4 0.4 33 3 32 305 74 0 73 0 -2.2 0 -2 -2.4 05/11/2005 22:10:00 12.8 0.7 14.1 10.3 12.7 0.8 14.1 9.9 0.4 0 0.4 0.4 35 4 40 305 75 0 76 0 -2.2 0 -2 -2.4 05/11/2005 22:20:00 12 0.6 13.3 10.3 12 0.6 13.7 10.3 0.4 0 0.4 0.4 36 3 33 305 77 0 76 0 -2.2 0 -2 -2.4 05/11/2005 22:30:00 11.6 0.6 13.3 9.5 11.6 0.7 13.3 9.5 0.4 0 0.4 0.4 39 5 40 305 78 0 79 0 -2.2 0 -2 -2.4 05/11/2005 22:40:00 12.4 0.5 13.7 10.3 12.3 0.7 13.7 9.5 0.4 0 0.4 0.4 37 3 35 305 80 0 79 0 -2.3 0 -2 -2.4 05/11/2005 22:50:00 11.9 0.5 13.3 10.3 11.9 0.6 13 9.5 0.4 0 0.4 0.4 38 4 42 305 82 0 81 0 -2.2 0 -2 -2.4 05/11/2005 23:00:00 12 0.6 13.3 10.7 12.1 0.6 13.7 9.9 0.4 0 0.4 0.4 36 5 32 305 83 0 82 0 -2.2 0 -2 -2.2 05/11/2005 23:10:00 11.4 0.6 13 9.5 11.3 0.8 13 8.8 0.4 0 0.4 0.4 42 3 40 305 84 0 84 0 -2.1 0 -2 -2.2 05/11/2005 23:20:00 11.8 0.6 13.3 10.3 11.7 0.6 13.3 9.9 0.4 0 0.4 0.4 40 3 42 305 84 0 85 0 -2.2 0 -2 -2.2 05/11/2005 23:30:00 11.5 0.7 13 9.5 11.4 0.8 13 9.1 0.4 0 0.4 0.4 41 5 45 305 85 0 85 0 -2.3 0 -1.8 -2.4 05/11/2005 23:40:00 10.9 0.8 13.3 8.8 10.9 0.8 13 8.8 0.4 0 0.4 0.4 43 6 37 305 85 0 86 0 -2.3 0 -2.2 -2.4 05/11/2005 23:50:00 10.6 0.6 12.2 9.1 10.6 0.7 12.2 9.1 0.4 0 0.4 0.4 41 4 49 305 86 0 86 0 -2.3 0 -2.2 -2.4 05/12/2005 00:00:00 10.3 0.6 11.8 8.8 10.1 0.6 11.5 8.4 0.4 0 0.4 0.4 41 4 47 305 87 0 87 0 -2.2 0 -1.8 -2.4 05/12/2005 00:10:00 10.5 0.8 12.2 8.8 10.5 0.8 12.2 8.8 0.4 0 0.4 0.4 33 5 39 305 88 0 88 0 -2.1 0 -2 -2.2 05/12/2005 00:20:00 10.6 0.5 11.8 8.8 10.5 0.6 11.8 8.4 0.4 0 0.4 0.4 36 6 40 305 89 0 89 0 -2.2 0 -2 -2.4 05/12/2005 00:30:00 10.5 0.8 13 8.8 10.3 0.8 13 8 0.4 0 0.4 0.4 35 7 30 305 89 0 89 0 -2.3 0 -2.2 -2.4 05/12/2005 00:40:00 10.4 0.7 11.8 8 10.3 0.7 12.2 8.4 0.4 0 0.4 0.4 38 6 29 305 89 0 90 0 -2.4 0 -2.2 -2.7 05/12/2005 00:50:00 11.1 0.7 12.6 8.8 11 0.8 13 8.8 0.4 0 0.4 0.4 36 4 40 305 89 0 90 0 -2.4 0 -2.2 -2.7 05/12/2005 01:00:00 10.9 0.5 12.2 9.1 10.8 0.6 12.2 8.8 0.4 0 0.4 0.4 35 5 29 305 91 0 91 0 -2.3 0 -2.2 -2.4 05/12/2005 01:10:00 11.2 0.6 12.6 9.5 11.2 0.6 12.6 9.1 0.4 0 0.4 0.4 38 4 35 305 91 0 91 0 -2.3 0 -2.2 -2.4 05/12/2005 01:20:00 11.3 0.7 13 9.5 11.1 0.7 13 9.1 0.4 0 0.4 0.4 39 4 42 305 91 0 91 0 -2.4 0 -2.2 -2.7 05/12/2005 01:30:00 11.7 0.8 13.7 9.1 11.6 0.9 14.1 9.1 0.4 0 0.4 0.4 37 4 39 305 91 0 91 0 -2.5 0 -2.2 -2.7 05/12/2005 01:40:00 11.4 0.6 12.6 9.1 11.3 0.7 13 9.1 0.4 0 0.4 0.4 39 4 40 305 91 0 91 0 -2.6 0 -2.4 -2.7 05/12/2005 01:50:00 11.4 0.7 13.3 9.1 11.3 0.8 13 8.8 0.4 0 0.4 0.4 33 5 33 305 92 0 92 0 -2.5 0 -2 -2.7 05/12/2005 02:00:00 11.2 0.7 12.6 9.1 11.1 0.7 12.6 9.1 0.4 0 0.4 0.4 34 5 39 305 93 0 93 0 -2.3 0 -2.2 -2.4 05/12/2005 02:10:00 10.8 0.6 12.2 9.1 10.7 0.6 12.2 8.8 0.4 0 0.4 0.4 34 3 35 305 93 0 93 0 -2.3 0 -2.2 -2.4 05/12/2005 02:20:00 11.4 0.6 12.6 9.9 11.2 0.7 12.6 9.1 0.4 0 0.4 0.4 37 4 35 305 92 0 93 0 -2.2 0 -2 -2.4 05/12/2005 02:30:00 11.5 0.6 13 9.5 11.4 0.7 13.3 8.8 0.4 0 0.4 0.4 31 3 33 305 92 0 92 0 -2.2 0 -2 -2.4 05/12/2005 02:40:00 11 0.7 12.2 8.8 10.8 0.8 12.2 8.4 0.4 0 0.4 0.4 31 4 32 305 91 0 91 0 -2.2 0 -2 -2.4 05/12/2005 02:50:00 10.2 0.7 11.8 8 10.1 0.8 11.8 7.6 0.4 0 0.4 0.4 43 7 30 305 90 0 91 0 -2.3 0 -2.2 -2.7 05/12/2005 03:00:00 10.8 0.8 13 8.8 10.8 0.9 12.6 8.8 0.4 0 0.4 0.4 40 4 40 305 90 0 90 0 -2.4 0 -2.2 -2.4 05/12/2005 03:10:00 10.9 0.6 12.2 9.1 10.8 0.7 12.2 8.8 0.4 0 0.4 0.4 36 6 44 305 91 0 91 0 -2.4 0 -1.8 -2.4 05/12/2005 03:20:00 11.5 0.8 13.3 9.1 11.4 0.8 13 9.1 0.4 0 0.4 0.4 31 6 32 305 92 0 92 0 -2.4 0 -2.2 -2.4 05/12/2005 03:30:00 11.2 0.5 12.6 9.5 11.2 0.6 12.6 9.1 0.4 0 0.4 0.4 38 4 39 305 91 0 91 0 -2.5 0 -2.2 -2.7 05/12/2005 03:40:00 10.8 0.6 12.2 8.8 10.7 0.7 12.2 8.4 0.4 0 0.4 0.4 41 4 42 305 91 0 91 0 -2.5 0 -2.4 -2.7 05/12/2005 03:50:00 10.6 0.6 12.6 9.1 10.6 0.7 13 8.8 0.4 0 0.4 0.4 39 3 38 305 92 0 92 0 -2.4 0 -2.2 -2.7 05/12/2005 04:00:00 11.1 0.7 12.6 8.8 11 0.8 13 8.4 0.4 0 0.4 0.4 39 4 41 305 92 0 92 0 -2.3 0 -2.2 -2.4 05/12/2005 04:10:00 11.3 0.7 13 9.5 11.2 0.8 13 8.8 0.4 0 0.4 0.4 38 4 34 305 92 0 91 0 -2.4 0 -2.2 -2.4 05/12/2005 04:20:00 11.2 0.6 12.6 9.5 11.1 0.6 12.6 9.5 0.4 0 0.4 0.4 37 4 29 305 91 0 91 0 -2.3 0 -2.2 -2.4 05/12/2005 04:30:00 10.8 0.6 12.2 9.1 10.8 0.6 12.6 8.8 0.4 0 0.4 0.4 39 3 39 305 90 0 90 0 -2.4 0 -2 -2.7 05/12/2005 04:40:00 10.7 0.7 12.6 8.4 10.6 0.8 12.6 8.4 0.4 0 0.4 0.4 39 4 42 305 89 0 89 0 -2.4 0 -2.2 -2.7 05/12/2005 04:50:00 10.4 0.7 11.8 8.4 10.2 0.8 11.8 8 0.4 0 0.4 0.4 37 5 33 305 89 0 89 0 -2.3 0 -2.2 -2.4 05/12/2005 05:00:00 10.3 0.6 11.8 8.4 10.2 0.7 12.2 8 0.4 0 0.4 0.4 34 4 32 305 88 0 88 0 -2.4 0 -2 -2.4 05/12/2005 05:10:00 11.5 0.7 13 9.1 11.5 0.8 13 8.8 0.4 0 0.4 0.4 27 3 25 305 87 0 88 0 -2.4 0 -1.8 -2.7 05/12/2005 05:20:00 11.1 0.7 13 9.1 11 0.8 12.6 8.8 0.4 0 0.4 0.4 31 5 33 305 87 0 87 0 -2.4 0 -2.2 -2.4 05/12/2005 05:30:00 11.3 0.9 13.3 9.5 11.1 1 13.3 8.8 0.4 0 0.4 0.4 33 3 32 305 87 0 87 0 -2.3 0 -2.2 -2.4 05/12/2005 05:40:00 11.1 0.7 12.6 9.1 11 0.8 12.6 8.4 0.4 0 0.4 0.4 35 3 33 305 86 0 86 0 -2.3 0 -2.2 -2.4 05/12/2005 05:50:00 11 0.6 12.6 9.5 10.9 0.6 12.2 9.1 0.4 0 0.4 0.4 33 4 29 305 85 0 86 0 -2.3 0 -2.2 -2.4 05/12/2005 06:00:00 11.3 0.8 13.3 9.1 11.2 0.9 13.3 9.1 0.4 0 0.4 0.4 32 4 33 305 85 0 84 0 -2.3 0 -2.2 -2.4 05/12/2005 06:10:00 11.9 0.7 13.7 8.8 11.8 0.8 13.7 9.1 0.4 0 0.4 0.4 31 4 37 305 84 0 84 0 -2.2 0 -2 -2.4 05/12/2005 06:20:00 11.7 0.7 13.3 9.5 11.6 0.8 13.3 9.5 0.4 0 0.4 0.4 32 4 28 305 83 0 84 0 -2.3 0 -2.2 -2.4 05/12/2005 06:30:00 12.1 0.7 13.7 10.3 12 0.8 13.7 9.1 0.4 0 0.4 0.4 33 3 38 305 83 0 83 0 -2.3 0 -2.2 -2.4 05/12/2005 06:40:00 11.5 0.6 13 9.5 11.4 0.7 13 9.9 0.4 0 0.4 0.4 35 3 35 305 82 0 82 0 -2.3 0 -2 -2.4 05/12/2005 06:50:00 11.8 0.7 13.3 9.9 11.7 0.7 13.3 9.9 0.4 0 0.4 0.4 30 4 34 305 81 0 81 0 -2.3 0 -2.2 -2.4 05/12/2005 07:00:00 12.1 0.8 13.7 9.9 12 1 14.1 9.5 0.4 0 0.4 0.4 28 4 26 305 80 0 80 0 -2.3 0 -2 -2.4 05/12/2005 07:10:00 12.2 0.8 14.1 9.5 12 1 14.1 9.9 0.4 0 0.4 0.4 28 5 31 305 79 0 79 0 -2.2 0 -2 -2.4 05/12/2005 07:20:00 12.8 0.7 14.1 10.7 12.7 0.8 14.5 10.3 0.4 0 0.4 0.4 30 3 39 305 78 0 78 0 -2.2 0 -2 -2.4 05/12/2005 07:30:00 12.4 0.9 13.7 9.5 12.2 1 14.1 8.8 0.4 0 0.4 0.4 27 5 29 305 77 0 77 0 -2.3 0 -2 -2.4 05/12/2005 07:40:00 11.9 0.8 13.3 9.5 12 0.9 13.7 9.1 0.4 0 0.4 0.4 28 5 31 305 76 0 76 0 -2.3 0 -1.8 -2.4 05/12/2005 07:50:00 12.8 1 15.3 9.1 12.6 1.1 15.3 9.5 0.4 0 0.4 0.4 27 4 29 305 75 0 75 0 -2.3 0 -2 -2.4 05/12/2005 08:00:00 12.7 0.8 14.1 10.3 12.6 0.8 14.5 10.3 0.4 0 0.4 0.4 25 4 21 305 74 0 74 0 -2.3 0 -2 -2.4 05/12/2005 08:10:00 12.6 0.5 13.7 10.7 12.5 0.6 14.1 10.7 0.4 0 0.4 0.4 31 3 32 305 73 0 73 0 -2.2 0 -2 -2.4 05/12/2005 08:20:00 12.3 0.6 13.7 10.3 12.3 0.7 14.1 9.9 0.4 0 0.4 0.4 33 3 35 305 71 0 72 0 -2.2 0 -2 -2.4 05/12/2005 08:30:00 13.2 0.6 14.5 11.1 13.1 0.8 14.9 11.1 0.4 0 0.4 0.4 28 3 27 305 69 1 69 0 -2.2 0 -1.8 -2.4 05/12/2005 08:40:00 13.5 0.7 14.9 11.1 13.4 0.9 15.3 10.7 0.4 0 0.4 0.4 31 3 32 305 67 0 66 0 -2.2 0 -2 -2.4 05/12/2005 08:50:00 13.7 0.6 15.3 11.1 13.6 0.7 15.6 11.1 0.4 0 0.4 0.4 33 4 31 305 65 0 66 0 -2.2 0 -1.8 -2.4 05/12/2005 09:00:00 13 0.8 14.5 10.3 12.9 0.9 14.5 10.3 0.4 0 0.4 0.4 35 4 36 305 64 0 64 0 -2.3 0 -2 -2.4 05/12/2005 09:10:00 12.9 0.7 14.5 11.1 12.8 0.9 14.9 10.7 0.4 0 0.4 0.4 30 4 31 305 62 0 63 0 -2.2 0 -1.8 -2.4 05/12/2005 09:20:00 13.6 0.6 15.3 11.8 13.5 0.7 15.3 11.8 0.4 0 0.4 0.4 30 3 33 305 61 1 61 0 -2.2 0 -1.8 -2.4 05/12/2005 09:30:00 13.1 0.8 14.5 11.1 12.9 0.9 14.9 10.7 0.4 0 0.4 0.4 33 3 27 305 59 0 59 0 -2.2 0 -2 -2.4 05/12/2005 09:40:00 12.2 0.8 13.7 10.3 12 0.9 13.7 9.5 0.4 0 0.4 0.4 32 4 35 305 57 0 57 0 -2.1 0 -1.8 -2.2 05/12/2005 09:50:00 12.7 0.6 14.1 10.7 12.6 0.7 14.1 10.3 0.4 0 0.4 0.4 32 4 28 305 56 0 56 0 -2 0.1 -1.8 -2.2 05/12/2005 10:00:00 13.4 0.6 14.5 11.8 13.3 0.7 14.5 10.7 0.4 0 0.4 0.4 32 4 37 305 53 1 55 0 -2.2 0 -2 -2.4 05/12/2005 10:10:00 13.3 0.8 15.3 10.3 13.3 0.9 15.3 9.9 0.4 0 0.4 0.4 31 5 32 305 51 0 51 0 -2.3 0 -2 -2.4 05/12/2005 10:20:00 13.7 0.8 15.3 11.5 13.6 1 15.3 10.7 0.4 0 0.4 0.4 35 3 36 305 50 0 51 0 -2.3 0 -2 -2.4 05/12/2005 10:30:00 12.8 0.9 14.5 10.7 12.7 1 14.5 9.5 0.4 0 0.4 0.4 34 3 32 305 50 0 50 0 -2.2 0 -2 -2.4 05/12/2005 10:40:00 13 0.7 14.9 10.3 12.8 0.8 14.5 9.9 0.4 0 0.4 0.4 33 4 27 305 49 0 50 0 -2.3 0 -2 -2.4 05/12/2005 10:50:00 12.3 0.8 13.7 9.5 12.3 0.9 14.1 9.5 0.4 0 0.4 0.4 33 4 28 305 49 0 49 0 -2.3 0 -2.2 -2.4 05/12/2005 11:00:00 13.4 1 15.6 10.7 13.2 1.2 16.1 9.9 0.4 0 0.4 0.4 31 4 36 305 49 0 49 0 -2.2 0 -2 -2.4 05/12/2005 11:10:00 14.1 0.7 15.6 11.8 14 0.8 16.1 11.1 0.4 0 0.4 0.4 30 3 29 305 48 0 48 0 -2.3 0 -2.2 -2.4 05/12/2005 11:20:00 13.8 0.7 15.3 11.8 13.5 0.8 15.6 11.1 0.4 0 0.4 0.4 31 4 33 305 47 0 47 0 -2.3 0 -2 -2.4 05/12/2005 11:30:00 14.2 0.9 16.1 11.8 14.1 1 16.1 10.7 0.4 0 0.4 0.4 30 3 29 305 47 0 47 0 -2.4 0 -2.2 -2.7 05/12/2005 11:40:00 13.9 0.6 15.3 12.2 13.9 0.7 15.6 11.8 0.4 0 0.4 0.4 30 3 30 305 46 0 47 0 -2.4 0 -2.4 -2.7 05/12/2005 11:50:00 13.8 0.8 15.6 10.7 13.6 0.8 16.4 11.1 0.4 0 0.4 0.4 28 3 31 305 46 0 46 0 -2.5 0 -2.4 -2.7 05/12/2005 12:00:00 13.2 0.7 15.3 11.1 13.1 0.8 14.9 10.3 0.4 0 0.4 0.4 26 4 28 305 46 0 46 0 -2.3 0 -2.2 -2.4 05/12/2005 12:10:00 13.6 1 15.6 9.9 13.4 1 15.6 9.9 0.4 0 0.4 0.4 30 3 31 305 48 0 47 0 -2.4 0 -2.2 -2.7 05/12/2005 12:20:00 14 0.8 15.6 11.5 13.9 0.9 15.6 11.1 0.4 0 0.4 0.4 28 4 27 305 48 0 48 0 -2.5 0 -2.2 -2.7 05/12/2005 12:30:00 13.6 0.7 15.3 11.5 13.5 0.7 15.6 10.7 0.4 0 0.4 0.4 27 3 27 305 48 0 48 0 -2.6 0 -2 -2.7 05/12/2005 12:40:00 13.4 0.8 15.3 11.5 13.3 0.9 15.3 11.1 0.4 0 0.4 0.4 27 4 30 305 49 0 48 0 -2.4 0 -2.2 -2.7 05/12/2005 12:50:00 12.8 0.9 14.9 10.7 12.7 1 15.3 10.3 0.4 0 0.4 0.4 28 3 25 305 49 0 50 0 -2.4 0 -2 -2.7 05/12/2005 13:00:00 13.1 0.6 14.5 11.1 13 0.7 14.9 10.7 0.4 0 0.4 0.4 27 4 29 305 49 0 49 0 -2.4 0 -2 -2.7 05/12/2005 13:10:00 13.6 0.8 15.3 11.1 13.5 0.9 15.3 10.7 0.4 0 0.4 0.4 29 3 31 305 48 0 48 0 -2.3 0 -1.8 -2.4 05/12/2005 13:20:00 13.5 0.9 15.3 11.1 13.3 0.9 14.9 11.1 0.4 0 0.4 0.4 31 3 33 305 47 1 48 0 -2.2 0 -2 -2.4 05/12/2005 13:30:00 14 0.8 15.6 12.2 13.8 0.8 16.1 11.8 0.4 0 0.4 0.4 28 3 28 305 45 1 44 0 -2.3 0 -2 -2.4 05/12/2005 13:40:00 13.4 0.8 15.3 10.3 13.3 1 15.3 10.3 0.4 0 0.4 0.4 28 3 25 305 43 0 43 0 -2.2 0 -1.8 -2.4 05/12/2005 13:50:00 13.1 0.7 14.5 10.7 13 0.8 14.5 10.3 0.4 0 0.4 0.4 31 4 26 305 41 1 42 0 -2.2 0 -2 -2.4 05/12/2005 14:00:00 13.7 0.7 15.3 11.1 13.7 0.8 15.3 10.7 0.4 0 0.4 0.4 34 3 35 305 39 0 40 0 -2.2 0 -2 -2.4 05/12/2005 14:10:00 13.5 0.7 15.3 11.5 13.4 0.8 15.3 10.7 0.4 0 0.4 0.4 33 3 29 305 38 0 39 0 -2.2 0 -1.8 -2.4 05/12/2005 14:20:00 13.5 0.7 15.3 11.1 13.4 0.8 15.6 11.1 0.4 0 0.4 0.4 36 4 35 305 37 0 37 0 -2.2 0 -2 -2.4 05/12/2005 14:30:00 14.5 0.7 16.1 12.2 14.3 0.9 16.1 11.8 0.4 0 0.4 0.4 32 4 34 305 35 0 36 0 -2.2 0 -2 -2.4 05/12/2005 14:40:00 14.3 0.8 16.1 11.5 14.2 1 16.1 10.7 0.4 0 0.4 0.4 31 4 35 305 34 0 34 0 -2.1 0.1 -1.8 -2.2 05/12/2005 14:50:00 13.9 0.8 16.1 10.7 13.8 1 16.4 11.1 0.4 0 0.4 0.4 33 3 35 305 33 0 33 0 -1.8 0 -1.5 -2 05/12/2005 15:00:00 13.8 0.8 16.1 11.5 13.6 1 16.1 10.3 0.4 0 0.4 0.4 30 3 27 305 30 1 32 0 -1.6 0 -1.3 -1.8 05/12/2005 15:10:00 13.6 1 15.6 11.1 13.4 1.1 15.3 10.7 0.4 0 0.4 0.4 33 4 38 305 27 1 28 0 -1.7 0 -1.5 -2 05/12/2005 15:20:00 13.5 0.7 14.9 11.5 13.3 0.9 15.3 10.7 0.4 0 0.4 0.4 30 3 32 305 25 0 25 0 -1.7 0.1 -1.3 -2 05/12/2005 15:30:00 13.9 0.8 16.1 11.8 13.9 1 16.4 11.1 0.4 0 0.4 0.4 27 3 27 305 24 1 24 0 -1.6 0 -1.3 -1.8 05/12/2005 15:40:00 13.8 0.6 15.3 11.5 13.8 0.8 15.6 11.5 0.4 0 0.4 0.4 29 3 29 305 22 1 21 0 -1.6 0 -1.1 -1.8 05/12/2005 15:50:00 13.8 0.6 15.6 11.1 13.7 0.8 15.6 10.7 0.4 0 0.4 0.4 30 4 26 305 21 0 21 0 -1.5 0 -1.1 -1.8 05/12/2005 16:00:00 13.2 0.8 14.9 10.3 13.1 0.9 15.3 10.7 0.4 0 0.4 0.4 29 4 29 305 20 0 20 0 -1.5 0.1 -1.1 -1.8 05/12/2005 16:10:00 13.2 0.9 14.9 10.7 13 1 14.9 10.7 0.4 0 0.4 0.4 28 4 26 305 18 0 19 0 -1.5 0.1 -1.1 -1.8 05/12/2005 16:20:00 13.5 1 16.1 10.3 13.3 1.2 16.4 9.9 0.4 0 0.4 0.4 28 4 30 305 19 0 19 0 -1.5 0.1 -0.8 -1.8 05/12/2005 16:30:00 14.2 0.8 16.1 12.2 14 1 16.4 11.1 0.4 0 0.4 0.4 28 5 19 305 18 0 18 0 -1.7 0.1 -1.1 -2 05/12/2005 16:40:00 13.7 0.8 14.9 10.7 13.6 0.9 15.3 10.3 0.4 0 0.4 0.4 31 3 31 305 18 0 19 0 -1.9 0 -1.8 -2.2 05/12/2005 16:50:00 13.4 0.8 15.3 10.7 13.3 0.9 15.3 9.9 0.4 0 0.4 0.4 32 3 31 305 19 0 20 0 -1.9 0 -1.3 -2.2 05/12/2005 17:00:00 13.2 0.8 15.3 9.1 13 0.9 15.3 9.5 0.4 0 0.4 0.4 30 3 30 305 20 0 20 0 -1.7 0 -1.3 -2 05/12/2005 17:10:00 13.4 1 15.3 10.3 13.3 1 15.6 9.9 0.4 0 0.4 0.4 29 4 31 305 19 0 18 0 -1.8 0 -1.3 -2 05/12/2005 17:20:00 13.7 0.7 15.3 11.8 13.8 0.8 15.6 11.1 0.4 0 0.4 0.4 24 3 22 305 19 0 19 0 -1.9 0.1 -1.3 -2.2 05/12/2005 17:30:00 13.1 0.8 15.3 10.7 12.9 0.9 15.3 9.9 0.4 0 0.4 0.4 29 3 32 305 18 0 18 0 -2.1 0 -1.8 -2.2 05/12/2005 17:40:00 13.2 0.9 15.6 10.3 13.1 1 15.6 9.9 0.4 0 0.4 0.4 29 4 27 305 19 0 19 0 -2 0.1 -1.8 -2.2 05/12/2005 17:50:00 13.4 0.8 15.3 10.7 13.4 1 15.3 10.7 0.4 0 0.4 0.4 31 3 32 305 20 0 20 0 -2 0 -1.8 -2 05/12/2005 18:00:00 13.5 1.1 16.1 10.7 13.3 1.2 16.1 9.9 0.4 0 0.4 0.4 26 4 25 305 20 0 20 0 -1.9 0.1 -1.5 -2.2 05/12/2005 18:10:00 13.8 0.9 16.4 11.1 13.7 1 16.1 11.1 0.4 0 0.4 0.4 28 3 30 305 21 0 21 0 -1.9 0.1 -1.3 -2 05/12/2005 18:20:00 14.3 0.7 16.1 12.2 14.1 0.9 15.6 10.7 0.4 0 0.4 0.4 30 3 28 305 21 0 21 0 -2.1 0.1 -1.8 -2.2 05/12/2005 18:30:00 13.8 0.7 15.6 11.8 13.7 0.8 15.6 10.7 0.4 0 0.4 0.4 28 4 32 305 22 0 22 0 -2.2 0 -1.8 -2.4 05/12/2005 18:40:00 13.8 1 16.1 11.5 13.6 1 16.1 10.3 0.4 0 0.4 0.4 30 3 31 305 23 0 23 0 -2.2 0 -1.8 -2.2 05/12/2005 18:50:00 14.1 0.8 15.6 11.5 13.9 0.9 15.6 11.5 0.4 0 0.4 0.4 29 3 28 305 23 0 23 0 -2.2 0 -2 -2.4 05/12/2005 19:00:00 13.6 0.8 15.3 11.5 13.4 0.9 15.3 11.1 0.4 0 0.4 0.4 29 3 30 305 24 0 24 0 -2.2 0 -2 -2.4 05/12/2005 19:10:00 13 1 15.3 10.7 12.8 1 15.3 9.9 0.4 0 0.4 0.4 28 4 28 305 25 0 25 0 -2.1 0 -2 -2.4 05/12/2005 19:20:00 13.4 1 15.6 10.7 13.3 1.2 16.1 9.9 0.4 0 0.4 0.4 26 4 23 305 25 0 26 0 -2.1 0.1 -1.8 -2.2 05/12/2005 19:30:00 13.5 0.8 15.3 10.7 13.4 1 15.6 9.9 0.4 0 0.4 0.4 31 4 30 305 25 0 24 0 -2.3 0 -2 -2.4 05/12/2005 19:40:00 13.2 1.1 14.9 9.5 13.1 1.1 15.3 9.5 0.4 0 0.4 0.4 30 4 26 305 24 0 24 0 -2.4 0 -2.2 -2.4 05/12/2005 19:50:00 13.9 0.9 15.6 10.7 13.8 1 15.3 10.7 0.4 0 0.4 0.4 31 4 29 305 25 0 25 0 -2.5 0 -2.2 -2.7 05/12/2005 20:00:00 13.7 0.9 15.6 11.1 13.4 1 15.6 10.3 0.4 0 0.4 0.4 30 4 26 305 25 0 26 0 -2.5 0.1 -2 -2.7 05/12/2005 20:10:00 14.4 0.8 16.1 11.5 14.2 0.9 16.1 10.7 0.4 0 0.4 0.4 28 4 29 305 26 0 26 0 -2.7 0 -2.4 -2.7 05/12/2005 20:20:00 13.2 0.9 15.3 10.7 13.1 1 15.3 9.5 0.4 0 0.4 0.4 33 4 25 305 28 0 27 0 -2.7 0 -2.4 -2.7 05/12/2005 20:30:00 13.4 0.8 15.3 11.1 13.3 0.9 15.3 10.7 0.4 0 0.4 0.4 33 4 35 305 29 0 29 0 -2.7 0 -2.4 -2.7 05/12/2005 20:40:00 13.5 0.9 15.3 10.7 13.3 1 15.3 10.3 0.4 0 0.4 0.4 33 5 38 305 31 0 31 0 -2.6 0 -2.4 -2.7 05/12/2005 20:50:00 13.9 0.9 15.6 11.1 13.8 0.9 16.1 11.1 0.4 0 0.4 0.4 30 4 24 305 31 0 31 0 -2.7 0 -2.4 -2.7 05/12/2005 21:00:00 13.5 0.8 15.3 11.1 13.5 0.8 15.6 11.5 0.4 0 0.4 0.4 32 4 35 305 32 0 32 0 -2.7 0 -2.4 -2.7 05/12/2005 21:10:00 13.5 0.9 16.1 11.1 13.3 1 15.3 10.3 0.4 0 0.4 0.4 33 4 31 305 33 0 32 0 -2.7 0 -2.2 -2.9 05/12/2005 21:20:00 13.8 0.9 15.6 11.1 13.7 0.9 16.1 11.1 0.4 0 0.4 0.4 32 3 31 305 34 0 34 0 -2.8 0 -2.4 -2.9 05/12/2005 21:30:00 14.5 1 16.8 11.8 14.5 1.1 17.2 11.8 0.4 0 0.4 0.4 29 4 30 305 35 0 35 0 -2.8 0 -2.7 -3.1 05/12/2005 21:40:00 14 0.8 15.6 12.2 13.9 1 15.6 11.1 0.4 0 0.4 0.4 33 3 30 305 35 0 35 0 -2.8 0 -2.4 -2.9 05/12/2005 21:50:00 14.8 0.8 16.8 11.8 14.7 0.9 16.8 11.5 0.4 0 0.4 0.4 31 3 37 305 36 0 35 0 -2.8 0 -2.7 -2.9 05/12/2005 22:00:00 14.7 0.9 16.8 12.6 14.5 1 16.8 11.8 0.4 0 0.4 0.4 32 4 23 305 36 0 36 0 -2.7 0 -2.4 -2.7 05/12/2005 22:10:00 15.9 0.8 17.9 13.3 15.8 0.9 18.3 13 0.4 0 0.4 0.4 30 3 31 305 37 0 37 0 -2.8 0 -2.4 -2.9 05/12/2005 22:20:00 15.1 1 17.2 11.8 15 1 17.2 11.5 0.4 0 0.4 0.4 29 3 25 305 37 0 37 0 -2.7 0 -2.2 -2.7 05/12/2005 22:30:00 14.9 1 17.2 12.2 14.7 1.2 16.8 11.5 0.4 0 0.4 0.4 33 3 37 305 37 0 38 0 -2.7 0 -2.4 -2.7 05/12/2005 22:40:00 14.9 1.1 17.2 11.5 14.7 1.2 16.8 10.3 0.4 0 0.4 0.4 34 4 35 305 38 0 38 0 -2.7 0 -2.2 -2.9 05/12/2005 22:50:00 15.1 0.8 17.2 12.6 15 0.9 17.2 12.6 0.4 0 0.4 0.4 36 3 42 305 39 0 39 0 -2.8 0 -2.4 -2.9 05/12/2005 23:00:00 14.4 0.9 16.4 11.8 14.3 1 16.4 11.5 0.4 0 0.4 0.4 35 4 37 305 39 0 39 0 -2.7 0 -2.7 -2.9 05/12/2005 23:10:00 13.9 0.8 16.1 11.8 13.8 1 16.1 11.1 0.4 0 0.4 0.4 35 4 31 305 40 0 40 0 -2.7 0 -2 -2.7 05/12/2005 23:20:00 14.5 0.9 16.4 11.8 14.4 1 16.8 11.5 0.4 0 0.4 0.4 32 4 31 305 41 0 41 0 -2.7 0 -2.4 -2.7 05/12/2005 23:30:00 15 1 17.2 12.2 14.9 1.1 17.2 11.8 0.4 0 0.4 0.4 31 4 35 305 42 0 42 0 -2.7 0 -2.4 -2.9 05/12/2005 23:40:00 15.7 0.7 17.6 13.3 15.7 0.9 17.9 13 0.4 0 0.4 0.4 32 3 31 305 42 0 42 0 -2.8 0 -2.7 -2.9 05/12/2005 23:50:00 16 0.8 17.6 13.3 15.9 0.8 17.9 13.3 0.4 0 0.4 0.4 33 3 35 305 43 0 43 0 -2.8 0 -2.7 -2.9 05/13/2005 00:00:00 15.4 1 17.6 12.6 15.3 1.1 17.6 11.8 0.4 0 0.4 0.4 34 3 37 305 44 0 44 0 -2.7 0 -2.4 -2.9 05/13/2005 00:10:00 15.6 0.8 17.6 12.6 15.4 1 17.6 12.6 0.4 0 0.4 0.4 35 4 35 305 45 0 45 0 -2.7 0 -2.7 -2.7 05/13/2005 00:20:00 15.5 0.9 17.6 13 15.4 1 17.6 12.2 0.4 0 0.4 0.4 33 3 32 305 45 0 45 0 -2.7 0 -2.4 -2.7 05/13/2005 00:30:00 15.7 0.6 16.8 13 15.5 0.7 17.2 13 0.4 0 0.4 0.4 32 3 32 305 45 0 45 0 -2.7 0 -2.4 -2.9 05/13/2005 00:40:00 15.8 0.5 17.2 14.1 15.7 0.7 17.6 13.7 0.4 0 0.4 0.4 34 3 32 305 45 0 45 0 -2.8 0 -2.7 -2.9 05/13/2005 00:50:00 15.6 1 17.6 13.3 15.4 1 17.9 13.3 0.4 0 0.4 0.4 32 4 29 305 45 0 46 0 -2.8 0 -2.7 -2.9 05/13/2005 01:00:00 15.4 0.9 17.2 12.2 15.2 1 17.2 11.8 0.4 0 0.4 0.4 34 3 35 305 46 0 46 0 -2.7 0 -2.4 -2.9 05/13/2005 01:10:00 14.7 1.1 16.8 11.8 14.5 1.3 17.2 11.5 0.4 0 0.4 0.4 33 4 33 305 46 0 47 0 -2.7 0 -2.4 -2.7 05/13/2005 01:20:00 15.1 1 17.2 12.2 15.1 1 17.9 12.2 0.4 0 0.4 0.4 33 5 29 305 47 0 47 0 -2.7 0 -2.4 -2.7 05/13/2005 01:30:00 15.6 0.8 18.3 13.3 15.5 0.8 17.9 13 0.4 0 0.4 0.4 32 4 25 305 47 0 47 0 -2.6 0 -2.4 -2.7 05/13/2005 01:40:00 15.4 0.9 17.6 12.6 15.3 1 17.6 12.2 0.4 0 0.4 0.4 32 4 28 305 46 0 46 0 -2.6 0 -2.4 -2.7 05/13/2005 01:50:00 16.2 0.9 17.9 13.7 16 0.9 17.9 13 0.4 0 0.4 0.4 30 3 34 305 46 0 46 0 -2.6 0 -2.4 -2.7 05/13/2005 02:00:00 15.4 1 17.9 13 15.1 1.1 17.2 11.8 0.4 0 0.4 0.4 32 4 34 305 45 0 45 0 -2.6 0 -2.4 -2.7 05/13/2005 02:10:00 14.9 0.8 16.4 11.8 14.8 1 16.8 12.2 0.4 0 0.4 0.4 35 3 34 305 45 0 45 0 -2.7 0 -2.4 -2.7 05/13/2005 02:20:00 15.2 1.1 17.6 12.2 15 1.2 17.6 11.5 0.4 0 0.4 0.4 31 4 36 305 45 0 45 0 -2.6 0 -2.4 -2.7 05/13/2005 02:30:00 14.6 1.1 17.6 11.8 14.4 1.1 17.2 11.8 0.4 0 0.4 0.4 31 3 32 305 45 0 45 0 -2.4 0 -2.2 -2.7 05/13/2005 02:40:00 16.3 0.9 18.7 13.7 16.2 0.9 18.7 13.7 0.4 0 0.4 0.4 30 3 28 305 45 0 45 0 -2.5 0 -2.4 -2.7 05/13/2005 02:50:00 15.9 0.9 17.9 13 15.6 1 17.6 13 0.4 0 0.4 0.4 34 3 34 305 44 0 44 0 -2.5 0 -2.4 -2.7 05/13/2005 03:00:00 15.1 0.9 17.6 13 15 0.9 17.2 12.2 0.4 0 0.4 0.4 33 4 29 305 43 0 43 0 -2.4 0 -2 -2.7 05/13/2005 03:10:00 15.7 0.9 17.6 13.3 15.6 1 17.6 12.6 0.4 0 0.4 0.4 32 3 30 305 43 0 43 0 -2.4 0 -2.2 -2.7 05/13/2005 03:20:00 15.6 1 17.9 13 15.4 1 17.6 12.6 0.4 0 0.4 0.4 29 3 28 305 43 0 43 0 -2.3 0 -1.8 -2.4 05/13/2005 03:30:00 16 1 17.9 11.5 15.8 1.1 17.9 12.2 0.4 0 0.4 0.4 29 3 25 305 43 0 43 0 -2.3 0 -2.2 -2.4 05/13/2005 03:40:00 14.9 1 17.2 12.2 14.8 1 17.2 12.2 0.4 0 0.4 0.4 30 3 31 305 42 0 42 0 -2.3 0 -2 -2.4 05/13/2005 03:50:00 15.9 0.8 17.9 13.3 15.8 0.9 18.7 13 0.4 0 0.4 0.4 30 3 24 305 42 0 42 0 -2.2 0 -1.8 -2.4 05/13/2005 04:00:00 15.6 0.7 17.2 13 15.4 0.8 17.2 12.6 0.4 0 0.4 0.4 31 3 25 305 42 0 41 0 -2.2 0 -2 -2.4 05/13/2005 04:10:00 15.1 0.8 16.8 12.6 14.9 0.9 16.8 12.6 0.4 0 0.4 0.4 30 3 29 305 41 0 41 0 -2.2 0 -2 -2.4 05/13/2005 04:20:00 14.8 1 17.2 11.8 14.6 1.1 17.2 11.5 0.4 0 0.4 0.4 31 3 30 305 41 0 41 0 -2.2 0 -2 -2.4 05/13/2005 04:30:00 14.7 1 17.2 12.2 14.5 1.1 17.6 11.8 0.4 0 0.4 0.4 32 4 35 305 42 0 41 0 -2.2 0 -2 -2.4 05/13/2005 04:40:00 15.5 0.8 17.2 13 15.3 0.9 17.6 13 0.4 0 0.4 0.4 29 3 32 305 42 0 42 0 -2.3 0 -2.2 -2.4 05/13/2005 04:50:00 16 0.7 17.6 13.7 15.8 0.8 17.2 13.3 0.4 0 0.4 0.4 31 3 32 305 43 0 43 0 -2.3 0 -2.2 -2.4 05/13/2005 05:00:00 15 0.9 16.8 12.6 15 1 17.2 12.2 0.4 0 0.4 0.4 31 4 33 305 43 0 43 0 -2.3 0 -2.2 -2.4 05/13/2005 05:10:00 15.7 0.7 17.2 13.3 15.5 0.9 17.2 12.2 0.4 0 0.4 0.4 34 2 34 305 44 0 44 0 -2.4 0 -2.2 -2.7 05/13/2005 05:20:00 15.3 0.8 17.6 13 15.2 0.8 17.2 12.6 0.4 0 0.4 0.4 32 3 25 305 45 0 45 0 -2.4 0 -2 -2.4 05/13/2005 05:30:00 15.2 0.9 16.8 12.6 15.1 0.9 17.2 12.2 0.4 0 0.4 0.4 32 3 35 305 47 0 46 0 -2.5 0 -2.4 -2.7 05/13/2005 05:40:00 14.8 0.8 16.4 12.2 14.6 0.9 16.4 11.1 0.4 0 0.4 0.4 30 3 30 305 48 0 48 0 -2.4 0 -2.2 -2.4 05/13/2005 05:50:00 14.5 1 16.4 11.8 14.3 1.1 16.4 11.1 0.4 0 0.4 0.4 33 3 33 305 48 0 48 0 -2.4 0 -2.2 -2.7 05/13/2005 06:00:00 14.6 0.7 16.4 11.8 14.5 0.8 16.4 11.8 0.4 0 0.4 0.4 31 3 32 305 49 0 48 0 -2.5 0 -2.4 -2.7 05/13/2005 06:10:00 14.9 0.8 16.8 12.6 14.6 0.9 16.4 12.6 0.4 0 0.4 0.4 31 3 31 305 49 0 49 0 -2.5 0 -2.4 -2.7 05/13/2005 06:20:00 14.9 0.8 16.8 12.2 14.7 1 16.8 11.8 0.4 0 0.4 0.4 31 4 33 305 48 0 49 0 -2.5 0 -2.4 -2.7 05/13/2005 06:30:00 14.7 0.8 16.4 11.8 14.6 0.9 16.4 12.2 0.4 0 0.4 0.4 31 3 27 305 48 0 48 0 -2.6 0 -2 -2.7 05/13/2005 06:40:00 14 0.8 16.1 11.8 13.8 0.9 16.1 11.1 0.4 0 0.4 0.4 34 3 34 305 48 0 48 0 -2.5 0 -2 -2.7 05/13/2005 06:50:00 15.3 1 17.6 12.2 15.1 1 17.2 11.5 0.4 0 0.4 0.4 33 3 31 305 48 0 48 0 -2.6 0 -2.2 -2.7 05/13/2005 07:00:00 14.5 1.1 17.2 11.1 14.3 1.3 17.2 9.9 0.4 0 0.4 0.4 33 4 30 305 47 0 48 0 -2.4 0 -2.2 -2.7 05/13/2005 07:10:00 14.8 0.7 16.4 12.2 14.7 0.8 16.4 12.2 0.4 0 0.4 0.4 33 3 36 305 47 0 46 0 -2.6 0 -2 -2.7 05/13/2005 07:20:00 14 0.8 15.6 11.8 13.9 0.9 16.1 11.1 0.4 0 0.4 0.4 31 3 36 305 46 0 46 0 -2.5 0 -2.4 -2.7 05/13/2005 07:30:00 14.4 0.7 16.4 12.6 14.3 0.9 16.4 11.5 0.4 0 0.4 0.4 31 3 29 305 46 0 46 0 -2.5 0 -2 -2.7 05/13/2005 07:40:00 14.2 0.7 15.6 11.8 14 0.9 16.1 11.5 0.4 0 0.4 0.4 32 3 32 305 46 0 46 0 -2.5 0 -2.4 -2.7 05/13/2005 07:50:00 13.8 1 15.6 10.7 13.7 1 15.6 10.7 0.4 0 0.4 0.4 33 3 35 305 47 0 46 0 -2.5 0 -2.4 -2.7 05/13/2005 08:00:00 14.8 0.6 16.4 13 14.6 0.8 16.1 12.2 0.4 0 0.4 0.4 30 3 37 305 47 0 47 0 -2.6 0 -2.4 -2.7 05/13/2005 08:10:00 14.2 1 16.4 11.5 14.1 1.1 16.4 11.1 0.4 0 0.4 0.4 31 3 32 305 46 0 46 0 -2.5 0 -2.4 -2.7 05/13/2005 08:20:00 13.9 0.9 16.1 11.5 13.7 1 16.1 11.8 0.4 0 0.4 0.4 31 4 36 305 46 0 46 0 -2.5 0 -2.2 -2.7 05/13/2005 08:30:00 14.6 0.8 16.4 12.6 14.4 1 16.4 11.5 0.4 0 0.4 0.4 29 3 29 305 45 0 45 0 -2.6 0 -2.4 -2.7 05/13/2005 08:40:00 14.6 0.8 16.4 12.2 14.5 0.9 16.4 11.5 0.4 0 0.4 0.4 32 4 27 305 44 0 45 0 -2.5 0 -2.4 -2.7 05/13/2005 08:50:00 14.3 0.8 15.6 11.8 14.2 0.9 16.1 11.5 0.4 0 0.4 0.4 33 3 37 305 44 0 43 0 -2.5 0.1 -2.2 -2.7 05/13/2005 09:00:00 14.7 0.8 16.4 12.2 14.6 0.9 16.4 11.8 0.4 0 0.4 0.4 32 3 31 305 43 0 43 0 -2.6 0 -2.4 -2.7 05/13/2005 09:10:00 14 1 16.1 11.1 13.8 1.1 16.1 11.1 0.4 0 0.4 0.4 31 4 33 305 43 0 43 0 -2.4 0 -2 -2.7 05/13/2005 09:20:00 15.1 0.8 16.8 13.3 15.1 0.9 17.2 12.2 0.4 0 0.4 0.4 37 3 40 305 43 0 43 0 -2.5 0.1 -2.2 -2.7 05/13/2005 09:30:00 14.7 1 17.2 11.8 14.5 1.1 17.2 11.8 0.4 0 0.4 0.4 34 4 35 305 43 0 43 0 -2.4 0 -2.2 -2.7 05/13/2005 09:40:00 15.2 0.8 16.8 12.6 15 1 16.8 12.2 0.4 0 0.4 0.4 34 3 33 305 44 0 43 0 -2.4 0 -2.2 -2.7 05/13/2005 09:50:00 14.5 0.9 16.1 11.1 14.4 1 16.4 11.1 0.4 0 0.4 0.4 33 3 32 305 43 0 43 0 -2.4 0 -2.2 -2.4 05/13/2005 10:00:00 14.6 1.1 16.8 11.8 14.4 1.3 16.4 11.1 0.4 0 0.4 0.4 33 3 31 305 43 0 43 0 -2.3 0 -1.8 -2.4 05/13/2005 10:10:00 14.5 0.8 16.4 12.2 14.4 0.9 16.4 11.8 0.4 0 0.4 0.4 35 4 27 305 42 0 42 0 -2.3 0 -2 -2.4 05/13/2005 10:20:00 14.2 0.8 16.1 11.5 14 0.9 16.1 11.1 0.4 0 0.4 0.4 34 4 29 305 41 0 41 0 -2.3 0 -2 -2.4 05/13/2005 10:30:00 14.2 0.8 16.1 11.5 14.1 0.8 15.6 11.8 0.4 0 0.4 0.4 29 3 28 305 39 0 39 0 -2.2 0 -2 -2.2 05/13/2005 10:40:00 14 0.8 15.6 11.1 13.7 1 15.6 11.1 0.4 0 0.4 0.4 33 3 34 305 38 0 38 0 -2 0 -1.8 -2.2 05/13/2005 10:50:00 13.4 0.8 14.9 11.1 13.1 1 14.9 10.3 0.4 0 0.4 0.4 34 4 39 305 37 0 37 0 -2 0 -1.8 -2.2 05/13/2005 11:00:00 13.7 0.6 14.9 11.8 13.6 0.7 15.3 11.1 0.4 0 0.4 0.4 33 3 36 305 36 0 36 0 -2 0 -1.8 -2.2 05/13/2005 11:10:00 13.4 0.6 14.9 11.1 13.3 0.8 14.9 10.3 0.4 0 0.4 0.4 32 3 28 305 35 0 35 0 -1.1 1.6 4.9 -2 05/13/2005 11:20:00 12.5 0.6 14.1 10.7 12.4 0.7 13.7 10.3 0.4 0 0.4 0.4 32 3 30 305 33 0 34 0 -0.7 1.5 5.9 -2 05/13/2005 11:30:00 12.4 0.8 14.1 9.9 12.2 0.9 14.5 9.9 0.4 0 0.4 0.4 31 4 37 305 32 0 32 0 -0.3 2.3 8.4 -1.8 05/13/2005 11:40:00 13.1 0.9 14.9 10.7 12.9 1 14.9 10.3 0.4 0 0.4 0.4 33 3 33 305 31 0 31 0 -0.1 2 7.4 -1.8 05/13/2005 11:50:00 13.3 0.7 14.9 10.3 13.2 0.8 14.9 10.3 0.4 0 0.4 0.4 29 3 32 305 30 0 30 0 -0.8 1.5 4.9 -1.8 05/13/2005 12:00:00 13.6 0.7 15.3 11.8 13.6 0.9 15.3 10.3 0.4 0 0.4 0.4 30 3 30 305 28 1 28 0 -1.6 0 -1.1 -1.8 05/13/2005 12:10:00 13.9 1.1 16.1 10.3 13.8 1.1 16.1 10.7 0.4 0 0.4 0.4 30 4 27 305 27 0 27 0 -1.2 1.3 4.4 -1.8 05/13/2005 12:20:00 13.9 0.9 15.6 11.5 13.8 1 16.4 10.7 0.4 0 0.4 0.4 27 4 27 305 26 0 26 0 2.8 4.7 13.4 -1.8 05/13/2005 12:30:00 14.6 1 16.4 11.5 14.4 1 16.8 11.1 0.4 0 0.4 0.4 27 4 26 305 26 0 26 0 5.5 3.4 13.7 -1.8 05/13/2005 12:40:00 13.8 0.8 15.3 11.5 13.7 1 16.1 10.7 0.4 0 0.4 0.4 22 3 26 305 26 0 26 0 -0.1 2 7.2 -1.8 05/13/2005 12:50:00 14.2 1.1 16.4 11.1 14.1 1.2 16.8 11.1 0.4 0 0.4 0.4 24 3 23 305 26 0 26 0 0.5 2.9 8.9 -2 05/13/2005 13:00:00 14.5 0.9 16.4 12.2 14.5 1 16.8 11.5 0.4 0 0.4 0.4 26 3 25 305 26 0 26 0 2.6 2.6 8.4 -2 05/13/2005 13:10:00 14 0.9 15.6 11.5 13.9 1.1 16.1 11.5 0.4 0 0.4 0.4 25 3 28 305 26 0 26 0 5.2 2.2 9.2 -1.8 05/13/2005 13:20:00 14.1 0.7 16.1 11.8 14.1 0.7 15.6 11.8 0.4 0 0.4 0.4 25 4 29 305 26 0 26 0 1.2 2.2 7.7 -1.8 05/13/2005 13:30:00 14 1 16.1 11.5 13.9 1.1 16.1 10.7 0.4 0 0.4 0.4 26 4 22 305 26 0 26 0 -0.8 1.4 4.4 -1.8 05/13/2005 13:40:00 14.5 0.7 16.1 12.2 14.5 0.8 16.4 12.2 0.4 0 0.4 0.4 25 3 26 305 26 0 26 0 -1 1.3 4.2 -2 05/13/2005 13:50:00 14.2 0.9 16.8 11.8 14.2 1 17.2 11.1 0.4 0 0.4 0.4 25 4 29 305 26 0 26 0 -0.9 1.2 4.9 -1.8 05/13/2005 14:00:00 13.8 1 16.1 10.7 13.7 1 15.6 10.3 0.4 0 0.4 0.4 26 4 27 305 26 0 26 0 -1.4 0.3 0.6 -1.8 05/13/2005 14:10:00 13.6 0.9 15.6 10.7 13.6 1 15.6 11.1 0.4 0 0.4 0.4 24 3 25 305 26 0 26 0 -1.2 0 -1.1 -1.3 05/13/2005 14:20:00 13.5 0.9 15.3 11.1 13.5 1 16.1 10.7 0.4 0 0.4 0.4 24 4 22 305 25 0 25 0 -1.2 0 -1.1 -1.3 05/13/2005 14:30:00 13.2 0.9 15.6 10.7 13.1 1 15.3 9.9 0.4 0 0.4 0.4 24 4 29 305 24 0 24 0 -1.1 0.1 -0.6 -1.3 05/13/2005 14:40:00 13.4 0.8 15.3 10.7 13.4 0.9 15.6 10.3 0.4 0 0.4 0.4 24 3 22 305 24 0 24 0 -0.9 0 -0.1 -1.1 05/13/2005 14:50:00 12.8 0.9 14.9 10.7 12.7 1 14.9 10.3 0.4 0 0.4 0.4 24 4 23 305 23 1 24 0 -0.7 0 0.1 -1.1 05/13/2005 15:00:00 13 0.8 14.5 11.1 12.9 0.8 14.9 10.7 0.4 0 0.4 0.4 26 3 31 305 21 0 21 0 -0.9 0.1 -0.4 -1.1 05/13/2005 15:10:00 13.1 0.8 14.5 10.3 13.1 0.9 14.9 10.3 0.4 0 0.4 0.4 25 3 22 305 20 0 20 0 -1 0.1 -0.4 -1.1 05/13/2005 15:20:00 13.2 0.9 14.9 9.9 13.1 1 15.3 10.3 0.4 0 0.4 0.4 26 4 30 305 20 0 20 0 -1.1 0 -0.6 -1.3 05/13/2005 15:30:00 12.7 0.9 14.9 10.7 12.7 1 15.3 10.3 0.4 0 0.4 0.4 25 3 21 305 21 0 21 0 -1.1 0 -0.6 -1.3 05/13/2005 15:40:00 14.5 1.1 16.8 11.8 14.5 1.2 16.8 11.1 0.4 0 0.4 0.4 21 3 18 305 22 0 22 0 -1.2 0 -0.6 -1.5 05/13/2005 15:50:00 14.6 1.2 16.8 11.1 14.4 1.4 16.8 10.3 0.4 0 0.4 0.4 25 3 22 305 22 0 22 0 -1.3 0 -0.6 -1.5 05/13/2005 16:00:00 14 0.9 16.1 11.8 13.9 1 16.1 10.7 0.4 0 0.4 0.4 23 3 24 305 22 0 22 0 -1.3 0 -0.6 -1.5 05/13/2005 16:10:00 13.8 1.2 16.8 11.5 13.7 1.2 16.8 11.1 0.4 0 0.4 0.4 23 4 24 305 23 0 23 0 -1.3 0 -1.1 -1.5 05/13/2005 16:20:00 13.3 1 16.1 10.7 13.3 1 16.1 10.3 0.4 0 0.4 0.4 24 4 19 305 23 0 23 0 -1.4 0 -0.8 -1.5 05/13/2005 16:30:00 13.9 1 15.6 11.1 13.9 1 16.1 11.1 0.4 0 0.4 0.4 22 4 24 305 23 0 23 0 -1.5 0 -1.3 -1.8 05/13/2005 16:40:00 13.9 0.8 15.6 11.5 13.9 1 15.6 11.5 0.4 0 0.4 0.4 23 4 22 305 23 0 23 0 -1.5 0 -1.3 -1.8 05/13/2005 16:50:00 13.5 0.8 15.3 10.7 13.5 1 15.6 10.7 0.4 0 0.4 0.4 24 3 24 305 23 0 23 0 -1.5 0 -1.3 -1.8 05/13/2005 17:00:00 13.9 0.8 15.3 11.8 13.8 0.9 15.6 11.1 0.4 0 0.4 0.4 26 3 26 305 23 0 24 0 -1.5 0 -1.3 -1.8 05/13/2005 17:10:00 13.6 0.8 15.3 11.5 13.5 0.9 15.6 10.7 0.4 0 0.4 0.4 23 4 21 305 23 0 23 0 -1.5 0.1 -1.1 -1.8 05/13/2005 17:20:00 14 0.6 15.3 11.1 14 0.7 15.6 11.5 0.4 0 0.4 0.4 24 3 22 305 23 0 24 0 -1.6 0 -1.1 -1.8 05/13/2005 17:30:00 13.8 0.8 15.6 11.5 13.8 0.9 16.1 10.7 0.4 0 0.4 0.4 24 4 27 305 24 0 24 0 -1.5 0.1 -1.3 -1.8 05/13/2005 17:40:00 13.6 1.1 15.6 10.3 13.5 1.3 16.1 9.9 0.4 0 0.4 0.4 22 4 18 305 24 0 24 0 -1.6 0 -1.1 -1.8 05/13/2005 17:50:00 13.9 0.8 15.6 11.8 14 0.9 16.1 11.5 0.4 0 0.4 0.4 22 3 25 305 24 0 24 0 -1.6 0 -1.1 -1.8 05/13/2005 18:00:00 14.6 1 17.2 11.5 14.5 1.1 17.2 11.1 0.4 0 0.4 0.4 22 4 19 305 24 0 25 0 -1.6 0 -1.1 -1.8 05/13/2005 18:10:00 14.9 0.8 16.8 11.5 14.7 1 16.4 11.5 0.4 0 0.4 0.4 24 4 27 305 24 0 24 0 -1.6 0 -1.5 -1.8 05/13/2005 18:20:00 14.5 1.3 17.2 11.8 14.4 1.3 17.6 11.1 0.4 0 0.4 0.4 22 4 25 305 24 0 25 0 -1.5 0 -1.1 -1.8 05/13/2005 18:30:00 15 1.3 17.2 11.8 14.8 1.5 17.6 11.1 0.4 0 0.4 0.4 24 4 23 305 24 0 25 0 -1.6 0 -1.3 -1.8 05/13/2005 18:40:00 14.9 1.2 17.2 12.2 14.8 1.3 17.6 11.1 0.4 0 0.4 0.4 23 4 20 305 24 0 24 0 -1.5 0 -1.3 -1.8 05/13/2005 18:50:00 15.2 1.2 17.6 11.8 15.1 1.3 18.3 11.5 0.4 0 0.4 0.4 24 4 22 305 24 0 24 0 -1.6 0 -1.3 -1.8 05/13/2005 19:00:00 15.3 1 17.2 12.6 15.1 1 17.6 11.8 0.4 0 0.4 0.4 23 4 22 305 24 0 24 0 -1.6 0 -1.3 -1.8 05/13/2005 19:10:00 14.8 0.9 16.8 12.2 14.7 1 17.2 11.8 0.4 0 0.4 0.4 25 3 23 305 24 0 24 0 -1.6 0 -1.5 -1.8 05/13/2005 19:20:00 14.7 1.1 16.8 10.7 14.6 1.3 17.2 10.3 0.4 0 0.4 0.4 23 4 20 305 24 0 24 0 -1.7 0 -1.3 -1.8 05/13/2005 19:30:00 15 1 17.2 11.8 14.8 1.2 17.6 11.5 0.4 0 0.4 0.4 24 4 21 305 24 0 24 0 -1.7 0 -1.8 -1.8 05/13/2005 19:40:00 15 0.9 16.4 11.8 15 1 17.2 11.5 0.4 0 0.4 0.4 25 3 25 305 25 0 25 0 -1.7 0 -1.3 -2 05/13/2005 19:50:00 14.6 1 16.8 11.8 14.4 1 17.6 11.8 0.4 0 0.4 0.4 26 4 27 305 25 0 25 0 -1.8 0 -1.8 -2 05/13/2005 20:00:00 15 0.8 16.8 13 14.9 0.8 17.2 13 0.4 0 0.4 0.4 25 4 30 305 25 0 25 0 -1.7 0 -1.8 -2 05/13/2005 20:10:00 13.7 1 16.1 10.7 13.5 1.2 16.1 10.3 0.4 0 0.4 0.4 27 5 24 305 26 0 26 0 -1.8 0 -1.8 -2 05/13/2005 20:20:00 13.9 1 16.1 11.1 13.7 1.1 16.1 11.1 0.4 0 0.4 0.4 27 4 23 305 26 0 26 0 -1.8 0 -1.5 -2 05/13/2005 20:30:00 14 0.9 16.4 11.8 14 1 16.4 11.5 0.4 0 0.4 0.4 27 4 24 305 27 0 27 0 -1.8 0 -1.8 -2 05/13/2005 20:40:00 14.4 1 16.4 11.1 14.2 1.1 16.4 11.5 0.4 0 0.4 0.4 24 4 23 305 27 0 27 0 -1.8 0 -1.8 -2 05/13/2005 20:50:00 14.5 1 16.8 11.5 14.3 1.1 17.2 11.1 0.4 0 0.4 0.4 24 4 17 305 27 0 27 0 -1.8 0 -1.8 -2 05/13/2005 21:00:00 13.9 1.1 16.1 10.7 13.7 1.2 16.8 10.3 0.4 0 0.4 0.4 25 4 24 305 27 0 28 0 -1.8 0 -1.8 -2 05/13/2005 21:10:00 14.5 0.9 17.6 12.6 14.4 1 17.6 12.2 0.4 0 0.4 0.4 25 4 21 305 28 0 28 0 -1.9 0 -1.8 -2 05/13/2005 21:20:00 15.1 1.1 17.2 11.8 15 1.1 17.6 12.2 0.4 0 0.4 0.4 22 4 26 305 28 0 28 0 -1.8 0 -1.8 -2 05/13/2005 21:30:00 14.7 1 17.2 12.2 14.7 1.1 17.2 11.1 0.4 0 0.4 0.4 26 4 24 305 28 0 28 0 -1.9 0 -1.5 -2 05/13/2005 21:40:00 15.3 1.3 18.3 11.5 15.1 1.3 17.9 11.8 0.4 0 0.4 0.4 22 4 23 305 28 0 28 0 -1.8 0 -1.8 -2 05/13/2005 21:50:00 15.6 1 17.9 11.8 15.6 1 17.9 12.2 0.4 0 0.4 0.4 24 3 24 305 28 0 28 0 -1.9 0 -1.8 -2 05/13/2005 22:00:00 14.5 1.1 16.8 11.5 14.3 1.3 17.2 11.1 0.4 0 0.4 0.4 23 4 27 305 28 0 27 0 -1.9 0 -1.8 -2 05/13/2005 22:10:00 15.7 1.3 19.1 11.8 15.7 1.3 19.1 12.6 0.4 0 0.4 0.4 21 4 23 305 28 0 28 0 -1.9 0 -1.8 -2 05/13/2005 22:20:00 14.6 0.9 16.4 12.2 14.5 1 16.8 11.5 0.4 0 0.4 0.4 24 3 27 305 28 0 28 0 -2 0 -1.8 -2 05/13/2005 22:30:00 14.3 0.8 16.4 11.8 14.2 1 16.4 11.1 0.4 0 0.4 0.4 21 4 31 305 28 0 28 0 -1.9 0 -1.8 -2 05/13/2005 22:40:00 15.1 1.1 17.6 11.5 15.1 1.1 17.6 11.5 0.4 0 0.4 0.4 21 3 23 305 29 0 29 0 -1.9 0 -1.8 -2 05/13/2005 22:50:00 15.7 1.1 18.3 12.6 15.6 1.2 18.3 12.2 0.4 0 0.4 0.4 21 4 22 305 29 0 29 0 -1.9 0 -1.8 -2 05/13/2005 23:00:00 15 1.3 18.7 11.8 14.8 1.4 18.3 11.5 0.4 0 0.4 0.4 23 4 19 305 28 0 28 0 -1.9 0 -1.8 -2 05/13/2005 23:10:00 16.1 1 18.3 13.3 16 1.1 18.3 13 0.4 0 0.4 0.4 20 3 21 305 28 0 28 0 -2 0 -1.8 -2 05/13/2005 23:20:00 14.7 1 16.8 11.8 14.4 1.1 16.8 11.8 0.4 0 0.4 0.4 23 3 24 305 28 0 28 0 -2 0 -1.8 -2 05/13/2005 23:30:00 14.4 1 17.2 11.8 14.2 1 16.4 10.7 0.4 0 0.4 0.4 22 5 23 305 29 0 28 0 -2 0 -1.8 -2 05/13/2005 23:40:00 14.6 0.8 16.8 11.8 14.5 0.9 16.8 11.8 0.4 0 0.4 0.4 23 4 24 305 29 0 29 0 -2.1 0 -2 -2.2 05/13/2005 23:50:00 14.9 1.2 17.2 11.8 14.9 1.3 17.6 11.1 0.4 0 0.4 0.4 23 4 25 305 29 0 29 0 -2.2 0 -2 -2.2 05/14/2005 00:00:00 14.6 1.1 16.8 11.1 14.3 1.3 16.8 11.1 0.4 0 0.4 0.4 25 4 26 305 29 0 29 0 -2.1 0 -1.8 -2.2 05/14/2005 00:10:00 14.9 1.2 17.6 11.8 14.8 1.2 17.6 11.5 0.4 0 0.4 0.4 23 4 24 305 30 0 29 0 -2.2 0 -2 -2.2 05/14/2005 00:20:00 15 1 17.2 11.8 14.8 1.1 17.6 11.8 0.4 0 0.4 0.4 24 4 26 305 30 0 30 0 -2.2 0 -2 -2.2 05/14/2005 00:30:00 15.5 1.1 17.6 12.2 15.3 1.2 17.6 11.8 0.4 0 0.4 0.4 23 3 27 305 30 0 30 0 -2.2 0 -2 -2.4 05/14/2005 00:40:00 15 1.1 17.9 11.1 15 1.2 17.6 11.1 0.4 0 0.4 0.4 23 4 21 305 30 0 30 0 -2.2 0 -2 -2.2 05/14/2005 00:50:00 15.3 1.2 18.3 12.2 15.1 1.3 18.3 11.8 0.4 0 0.4 0.4 21 4 13 305 30 0 30 0 -2.1 0 -1.8 -2.2 05/14/2005 01:00:00 14.3 1.3 17.2 10.7 14.2 1.5 17.2 10.7 0.4 0 0.4 0.4 22 5 23 305 30 0 30 0 -2 0 -1.8 -2 05/14/2005 01:10:00 13.9 1 16.8 11.1 13.8 1.1 17.2 10.7 0.4 0 0.4 0.4 23 5 21 305 30 0 30 0 -2 0 -2 -2.2 05/14/2005 01:20:00 14 1.3 17.6 10.3 14 1.5 17.6 9.9 0.4 0 0.4 0.4 22 4 27 305 30 0 30 0 -2 0 -2 -2.2 05/14/2005 01:30:00 15 1.3 17.9 11.8 15 1.3 17.9 10.7 0.4 0 0.4 0.4 20 4 23 305 29 0 29 0 -2 0 -2 -2.2 05/14/2005 01:40:00 14.7 1 16.8 11.5 14.7 1 17.2 12.2 0.4 0 0.4 0.4 20 4 19 305 28 0 28 0 -2 0 -2 -2.2 05/14/2005 01:50:00 15 1 18.3 12.2 15 1.1 18.3 12.2 0.4 0 0.4 0.4 18 4 12 305 28 0 28 0 -2 0 -2 -2.2 05/14/2005 02:00:00 15.4 1 18.3 13.3 15.4 1 18.3 13 0.4 0 0.4 0.4 19 4 14 305 27 0 27 0 -2.1 0 -2 -2.2 05/14/2005 02:10:00 14.1 1.3 17.2 11.5 14.1 1.4 17.2 10.7 0.4 0 0.4 0.4 20 4 23 305 27 0 27 0 -2 0 -1.8 -2.2 05/14/2005 02:20:00 14.1 1.1 17.2 10.3 14.1 1.1 17.2 10.7 0.4 0 0.4 0.4 19 4 17 305 26 0 26 0 -1.9 0 -1.3 -2 05/14/2005 02:30:00 13.7 0.9 16.1 11.5 13.8 1 16.4 10.7 0.4 0 0.4 0.4 10 4 20 305 26 0 26 0 -2 0.1 -1.8 -2.2 05/14/2005 02:40:00 13.3 1.2 16.4 9.9 13.4 1.2 16.8 9.9 0.4 0 0.4 0.4 10 4 9 305 26 0 26 0 -2 0 -2 -2.2 05/14/2005 02:50:00 13.6 1.1 17.2 10.7 13.6 1.2 16.8 9.9 0.4 0 0.4 0.4 15 5 15 305 27 0 27 0 -1.9 0 -1.8 -2 05/14/2005 03:00:00 14.7 1.3 17.9 10.7 14.6 1.5 17.9 9.9 0.4 0 0.4 0.4 18 4 13 305 26 0 27 0 -2 0 -2 -2.2 05/14/2005 03:10:00 14.6 1.1 17.2 11.1 14.5 1.1 17.2 11.1 0.4 0 0.4 0.4 17 4 18 305 25 0 25 0 -2.1 0 -1.8 -2.2 05/14/2005 03:20:00 15.3 1.1 18.3 12.2 15.2 1.2 18.3 12.2 0.4 0 0.4 0.4 16 4 19 305 24 0 24 0 -2.2 0 -2 -2.2 05/14/2005 03:30:00 15.1 1.1 17.2 11.1 15 1.2 17.6 11.1 0.4 0 0.4 0.4 18 4 16 305 24 0 24 0 -2.2 0 -2 -2.2 05/14/2005 03:40:00 14.7 1.1 17.2 11.5 14.7 1.2 17.6 11.5 0.4 0 0.4 0.4 20 3 18 305 23 0 24 0 -2.2 0 -2 -2.2 05/14/2005 03:50:00 15.5 1.1 18.7 12.6 15.5 1.2 18.7 12.2 0.4 0 0.4 0.4 18 4 16 305 23 0 23 0 -2.2 0 -2 -2.2 05/14/2005 04:00:00 14.7 1.3 17.6 11.1 14.8 1.3 17.9 11.1 0.4 0 0.4 0.4 17 6 17 305 22 0 22 0 -2.1 0 -2 -2.2 05/14/2005 04:10:00 14.6 1.1 16.8 11.8 14.7 1.1 17.2 10.7 0.4 0 0.4 0.4 9 3 5 305 22 0 23 0 -2.5 0 -2.2 -2.7 05/14/2005 04:20:00 14.7 0.9 16.8 11.8 14.8 0.9 17.2 11.8 0.4 0 0.4 0.4 9 4 13 305 23 0 23 0 -2.6 0.1 -2.4 -2.7 05/14/2005 04:30:00 13.8 0.8 15.6 11.1 13.9 0.9 16.1 11.1 0.4 0 0.4 0.4 4 4 6 305 24 0 24 0 -2.7 0 -2.4 -3.1 05/14/2005 04:40:00 13.7 1 15.6 10.7 13.9 1.2 16.1 10.7 0.4 0 0.4 0.4 6 4 7 305 26 0 26 0 -2.9 0 -2.7 -3.1 05/14/2005 04:50:00 14.4 0.9 16.1 11.5 14.5 1 16.4 11.8 0.4 0 0.4 0.4 5 3 8 305 27 0 27 0 -2.8 0 -2.7 -3.1 05/14/2005 05:00:00 13.9 1.1 16.1 10.7 14 1.2 16.4 10.7 0.4 0 0.4 0.4 6 4 2 305 28 0 28 0 -2.8 0 -2.7 -3.1 05/14/2005 05:10:00 14.5 0.9 16.8 11.8 14.5 1 17.2 11.1 0.4 0 0.4 0.4 6 3 5 305 29 0 29 0 -2.8 0 -2.7 -3.1 05/14/2005 05:20:00 14.2 1.2 16.8 9.5 14.3 1.3 16.8 9.9 0.4 0 0.4 0.4 6 4 11 305 30 0 29 0 -2.8 0 -2.4 -2.9 05/14/2005 05:30:00 14.3 1.1 17.2 11.1 14.4 1.2 17.6 11.5 0.4 0 0.4 0.4 6 4 7 305 30 0 30 0 -2.9 0 -2.7 -3.1 05/14/2005 05:40:00 14.9 0.8 16.8 12.6 14.9 1 17.6 12.2 0.4 0 0.4 0.4 8 3 11 305 31 0 31 0 -2.8 0 -2.7 -3.1 05/14/2005 05:50:00 14.6 1.1 17.2 11.8 14.7 1.3 17.6 11.1 0.4 0 0.4 0.4 9 3 9 305 31 0 31 0 -2.8 0 -2.7 -3.1 05/14/2005 06:00:00 14.7 0.8 16.8 11.8 14.8 0.9 16.8 11.5 0.4 0 0.4 0.4 8 3 10 305 31 0 30 0 -2.8 0 -2.7 -3.1 05/14/2005 06:10:00 14.8 0.9 16.8 12.6 14.9 1 17.2 12.2 0.4 0 0.4 0.4 8 3 9 305 30 0 30 0 -2.8 0 -2.7 -3.1 05/14/2005 06:20:00 15 1 17.2 12.6 15.1 1.1 17.6 12.2 0.4 0 0.4 0.4 8 4 11 305 30 0 31 0 -2.9 0 -2.7 -3.1 05/14/2005 06:30:00 14.8 0.9 16.8 12.6 14.8 1 17.6 12.2 0.4 0 0.4 0.4 5 3 6 305 30 0 31 0 -3.1 0.1 -2.7 -3.3 05/14/2005 06:40:00 14.4 0.9 16.8 12.2 14.6 1 17.2 11.5 0.4 0 0.4 0.4 4 4 3 305 31 0 31 0 -3.2 0 -3.1 -3.3 05/14/2005 06:50:00 15 0.9 17.2 12.6 15.2 0.9 17.2 13 0.4 0 0.4 0.4 4 3 3 305 32 0 32 0 -3.3 0 -3.1 -3.6 05/14/2005 07:00:00 14.3 1.1 16.8 11.8 14.4 1.2 16.8 11.1 0.4 0 0.4 0.4 4 4 8 305 32 0 33 0 -3.3 0 -3.1 -3.6 05/14/2005 07:10:00 15 0.9 17.9 12.6 15.2 1 17.2 12.2 0.4 0 0.4 0.4 5 3 3 305 33 0 33 0 -3.4 0 -3.3 -3.6 05/14/2005 07:20:00 14.3 1.1 16.8 11.1 14.5 1.2 17.2 11.5 0.4 0 0.4 0.4 6 4 3 305 33 0 33 0 -3.3 0 -3.1 -3.6 05/14/2005 07:30:00 15.1 1 17.6 11.8 15.2 1 17.9 12.2 0.4 0 0.4 0.4 8 5 13 305 34 0 34 0 -3.3 0 -3.1 -3.6 05/14/2005 07:40:00 14.5 1 17.2 12.2 14.6 1.1 17.2 12.2 0.4 0 0.4 0.4 8 4 8 305 34 0 34 0 -3.1 0 -2.9 -3.3 05/14/2005 07:50:00 14.9 1.1 17.6 11.1 15 1.2 17.6 11.5 0.4 0 0.4 0.4 7 4 8 305 33 0 33 0 -3.1 0 -2.9 -3.3 05/14/2005 08:00:00 14.7 1 16.8 11.5 14.8 1.1 17.2 11.1 0.4 0 0.4 0.4 9 3 5 305 32 0 33 0 -3.1 0 -2.9 -3.3 05/14/2005 08:10:00 14.4 0.9 16.4 11.1 14.5 1 16.4 11.1 0.4 0 0.4 0.4 8 4 0 305 32 0 32 0 -3.3 0 -3.1 -3.3 05/14/2005 08:20:00 14.6 1.1 16.8 11.8 14.7 1.1 17.2 12.2 0.4 0 0.4 0.4 9 4 9 305 31 0 32 0 -3.3 0 -3.1 -3.3 05/14/2005 08:30:00 14.7 1 16.4 12.2 14.8 1.1 17.9 11.8 0.4 0 0.4 0.4 9 3 9 305 31 0 31 0 -3.3 0 -3.1 -3.6 05/14/2005 08:40:00 15.1 1 17.2 12.2 15.3 1.2 17.2 11.8 0.4 0 0.4 0.4 8 3 7 305 31 0 31 0 -3.4 0 -3.1 -3.6 05/14/2005 08:50:00 14.5 1.1 16.8 11.1 14.6 1.2 16.8 11.1 0.4 0 0.4 0.4 11 4 10 305 30 0 30 0 -3.3 0 -3.1 -3.6 05/14/2005 09:00:00 14.8 1.1 16.8 11.5 14.8 1.1 17.2 11.1 0.4 0 0.4 0.4 12 4 16 305 30 0 29 0 -3.3 0 -3.1 -3.3 05/14/2005 09:10:00 15 1 17.6 12.2 15.1 1.1 17.9 11.8 0.4 0 0.4 0.4 13 4 14 305 29 0 29 0 -3.3 0 -3.1 -3.3 05/14/2005 09:20:00 15.1 1.1 17.6 12.6 15.1 1.1 17.6 12.2 0.4 0 0.4 0.4 12 3 7 305 29 0 29 0 -3.3 0 -2.9 -3.6 05/14/2005 09:30:00 14.8 1.1 16.8 11.5 14.8 1.3 16.8 11.5 0.4 0 0.4 0.4 12 3 12 305 29 0 29 0 -3.3 0 -3.1 -3.3 05/14/2005 09:40:00 14.5 1.1 17.6 11.8 14.5 1.2 17.9 11.1 0.4 0 0.4 0.4 11 4 11 305 29 0 28 0 -3.3 0 -2.7 -3.3 05/14/2005 09:50:00 14.8 1.1 17.2 11.8 14.9 1.2 17.6 11.5 0.4 0 0.4 0.4 9 4 10 305 28 0 28 0 -3.5 0 -3.1 -3.8 05/14/2005 10:00:00 15.5 1 17.9 13 15.6 1.1 17.9 12.2 0.4 0 0.4 0.4 11 3 12 305 28 0 28 0 -3.6 0 -3.3 -3.8 05/14/2005 10:10:00 15.2 1 17.6 12.2 15.2 1.1 17.9 12.2 0.4 0 0.4 0.4 9 3 7 305 27 0 27 0 -3.5 0 -3.1 -3.8 05/14/2005 10:20:00 15 1.1 17.2 12.2 15 1.2 17.9 11.8 0.4 0 0.4 0.4 10 4 11 305 27 0 26 0 -3.5 0 -3.3 -3.8 05/14/2005 10:30:00 14.9 1.1 17.2 11.8 14.9 1.2 17.6 11.5 0.4 0 0.4 0.4 11 4 17 305 26 0 26 0 -3.5 0 -3.1 -3.8 05/14/2005 10:40:00 14.8 1.3 17.6 11.8 14.7 1.4 17.9 11.5 0.4 0 0.4 0.4 11 3 10 305 25 0 26 0 -3.4 0 -3.1 -3.6 05/14/2005 10:50:00 15.1 0.9 17.6 12.6 15.2 1 17.2 12.6 0.4 0 0.4 0.4 13 3 9 305 25 0 25 0 -3.4 0 -3.3 -3.6 05/14/2005 11:00:00 15 1 17.2 11.1 15.1 1.1 17.6 11.1 0.4 0 0.4 0.4 10 3 8 305 24 0 25 0 -3.3 0 -3.3 -3.6 05/14/2005 11:10:00 14.7 1.1 16.8 11.5 14.7 1.2 17.2 11.5 0.4 0 0.4 0.4 8 4 358 305 25 0 25 0 -3.2 0 -3.1 -3.6 05/14/2005 11:20:00 15.1 1 17.6 11.5 15.1 1.1 17.9 11.5 0.4 0 0.4 0.4 10 4 15 305 24 0 24 0 -3.2 0 -3.1 -3.3 05/14/2005 11:30:00 14.5 1.1 17.2 11.1 14.6 1.2 17.6 11.8 0.4 0 0.4 0.4 10 4 13 305 24 0 24 0 -3 0 -2.7 -3.3 05/14/2005 11:40:00 14.5 1.1 17.2 11.5 14.6 1.2 17.2 10.7 0.4 0 0.4 0.4 10 3 14 305 23 0 24 0 -2.9 0 -2.4 -3.1 05/14/2005 11:50:00 15.1 1 17.6 12.6 15.1 1.2 17.6 12.2 0.4 0 0.4 0.4 10 3 11 305 22 0 22 0 -2.8 0 -2.4 -3.1 05/14/2005 12:00:00 15.2 0.8 17.6 13 15.3 0.9 17.6 13.3 0.4 0 0.4 0.4 9 4 5 305 21 0 21 0 -2.8 0 -2.7 -3.1 05/14/2005 12:10:00 14.2 1.1 17.2 11.5 14.3 1.3 17.6 11.5 0.4 0 0.4 0.4 9 4 5 305 20 0 20 0 -2.6 0.1 -2.4 -2.7 05/14/2005 12:20:00 14.9 1 16.8 11.8 15 1 17.2 11.8 0.4 0 0.4 0.4 8 4 6 305 19 0 19 0 -2.7 0 -2.4 -2.7 05/14/2005 12:30:00 14.4 1.1 17.2 10.7 14.4 1.1 16.8 11.5 0.4 0 0.4 0.4 9 4 4 305 18 0 18 0 -2.6 0.1 -2.2 -2.7 05/14/2005 12:40:00 14.4 1 16.8 11.5 14.5 1.1 17.2 11.5 0.4 0 0.4 0.4 5 4 5 305 17 0 18 0 -2.6 0.1 -2.4 -2.7 05/14/2005 12:50:00 14.4 1 16.4 11.8 14.5 1.1 16.8 11.8 0.4 0 0.4 0.4 7 4 4 305 17 0 17 0 -2.5 0.1 -2.2 -2.7 05/14/2005 13:00:00 14.4 1.1 17.2 11.8 14.4 1.2 17.2 11.1 0.4 0 0.4 0.4 8 5 3 305 17 0 17 0 -2.4 0.1 -2 -2.7 05/14/2005 13:10:00 14.6 1.1 18.3 11.1 14.6 1.2 17.6 11.1 0.4 0 0.4 0.4 10 4 13 305 16 0 16 0 -2.4 0 -2.2 -2.7 05/14/2005 13:20:00 14.4 1.1 17.2 11.1 14.5 1.2 17.2 10.7 0.4 0 0.4 0.4 8 4 6 305 16 0 16 0 -2.2 0 -2 -2.4 05/14/2005 13:30:00 14.4 1 16.8 11.8 14.5 1.1 16.8 11.1 0.4 0 0.4 0.4 9 4 11 305 16 0 16 0 -2.2 0.1 -1.8 -2.4 05/14/2005 13:40:00 14.6 1.2 17.6 11.5 14.6 1.3 17.6 11.1 0.4 0 0.4 0.4 5 4 5 305 16 0 16 0 -2.2 0.1 -1.5 -2.4 05/14/2005 13:50:00 14.5 1.1 16.8 11.8 14.6 1.2 17.2 11.1 0.4 0 0.4 0.4 5 4 12 305 16 0 16 0 -2.2 0 -2 -2.4 05/14/2005 14:00:00 15.1 1 17.2 11.5 15.2 1.1 17.6 11.5 0.4 0 0.4 0.4 4 3 5 305 15 0 15 0 -2.2 0 -2 -2.4 05/14/2005 14:10:00 14.3 1.1 16.4 11.1 14.3 1.2 16.8 11.1 0.4 0 0.4 0.4 4 4 2 305 16 0 15 0 -2 0.1 -1.8 -2.2 05/14/2005 14:20:00 14.3 1 16.8 11.8 14.4 1.1 16.8 11.5 0.4 0 0.4 0.4 6 4 5 305 16 0 16 0 -2 0 -1.8 -2.2 05/14/2005 14:30:00 14.1 1 16.4 11.5 14.2 1.1 16.8 10.7 0.4 0 0.4 0.4 5 4 4 305 16 0 15 0 -1.8 0 -1.3 -2 05/14/2005 14:40:00 13.4 1.2 16.1 10.3 13.4 1.4 16.4 9.5 0.4 0 0.4 0.4 4 4 4 305 15 0 15 0 -1.6 0.1 -1.1 -2 05/14/2005 14:50:00 14.2 1.3 17.6 10.7 14.2 1.5 17.6 10.3 0.4 0 0.4 0.4 6 5 7 305 15 0 15 0 -1.6 0 -1.3 -1.8 05/14/2005 15:00:00 14.2 1.1 17.2 11.1 14.3 1.2 17.2 10.7 0.4 0 0.4 0.4 5 4 11 305 14 0 14 0 -1.7 0 -1.3 -2 05/14/2005 15:10:00 14.5 1.2 17.6 11.5 14.5 1.2 17.2 11.5 0.4 0 0.4 0.4 7 4 3 305 14 0 14 0 -1.6 0 -1.3 -1.8 05/14/2005 15:20:00 14.8 1.3 17.9 11.5 14.8 1.4 18.3 11.5 0.4 0 0.4 0.4 5 4 8 305 14 0 13 0 -1.6 0 -1.3 -1.8 05/14/2005 15:30:00 15.2 1 17.6 12.2 15.2 1.1 17.9 11.8 0.4 0 0.4 0.4 8 3 3 305 13 0 13 0 -1.6 0 -1.3 -1.8 05/14/2005 15:40:00 14.4 1 16.8 11.1 14.5 1.1 17.2 11.5 0.4 0 0.4 0.4 6 4 5 305 13 0 13 0 -1.5 0 -1.1 -1.8 05/14/2005 15:50:00 14.3 1.2 16.8 10.3 14.3 1.3 16.8 10.3 0.4 0 0.4 0.4 6 4 8 305 13 0 13 0 -1.5 0.1 -1.1 -1.8 05/14/2005 16:00:00 14.5 1.1 16.8 11.1 14.6 1.3 17.6 9.9 0.4 0 0.4 0.4 4 3 3 305 13 0 13 0 -1.6 0.1 -1.1 -1.8 05/14/2005 16:10:00 14.1 1.2 16.8 11.1 14.3 1.3 17.2 10.7 0.4 0 0.4 0.4 5 4 1 305 13 0 13 0 -1.6 0 -1.1 -1.8 05/14/2005 16:20:00 14 1.1 16.8 11.1 14.1 1.2 17.2 10.3 0.4 0 0.4 0.4 7 4 3 305 13 0 13 0 -1.4 0 -1.1 -1.5 05/14/2005 16:30:00 13.7 1.1 16.8 11.5 13.6 1.1 16.4 10.7 0.4 0 0.4 0.4 12 4 11 305 12 0 12 0 -1 0 -0.6 -1.1 05/14/2005 16:40:00 14.3 1.3 17.9 11.5 14.3 1.5 17.6 10.3 0.4 0 0.4 0.4 14 4 14 305 11 1 11 0 -1.1 0.1 -0.4 -1.3 05/14/2005 16:50:00 15.4 1.1 17.9 12.2 15.3 1.3 17.9 11.8 0.4 0 0.4 0.4 15 4 11 305 9 0 9 0 -1.2 0.1 -0.4 -1.3 05/14/2005 17:00:00 16.4 1.3 18.7 12.6 16.3 1.4 19.1 11.5 0.4 0 0.4 0.4 16 3 19 305 7 0 8 0 -1.1 0 -0.6 -1.3 05/14/2005 17:10:00 15.9 1 17.9 12.2 15.9 1.1 18.3 12.2 0.4 0 0.4 0.4 15 4 12 305 6 0 6 0 -1.2 0.1 -0.6 -1.5 05/14/2005 17:20:00 14.6 1.2 17.2 11.5 14.6 1.3 17.2 10.7 0.4 0 0.4 0.4 8 4 13 305 6 0 6 0 -1.4 0 -0.6 -1.5 05/14/2005 17:30:00 14.1 1 16.8 11.1 14.1 1.1 17.2 11.1 0.4 0 0.4 0.4 11 4 10 305 6 0 6 0 -1.3 0.1 -0.6 -1.5 05/14/2005 17:40:00 14.9 0.9 17.2 12.6 14.8 1.1 17.6 11.8 0.4 0 0.4 0.4 12 3 12 305 5 0 5 0 -1.2 0 -0.6 -1.5 05/14/2005 17:50:00 15.1 1.1 17.2 11.8 15 1.3 17.2 11.8 0.4 0 0.4 0.4 15 5 15 305 4 0 5 0 -1.2 0 -0.6 -1.5 05/14/2005 18:00:00 14.1 0.9 16.4 10.7 14.1 1 16.4 11.1 0.4 0 0.4 0.4 13 4 18 305 4 0 4 0 -1.4 0.1 -0.6 -1.8 05/14/2005 18:10:00 14.4 1.1 16.8 11.1 14.5 1.1 16.8 11.1 0.4 0 0.4 0.4 11 4 7 305 4 0 4 0 -1.4 0 -0.6 -1.5 05/14/2005 18:20:00 14.8 1 16.8 11.8 14.7 1.1 17.2 11.1 0.4 0 0.4 0.4 14 4 18 305 4 0 4 0 -1.2 0 -0.6 -1.5 05/14/2005 18:30:00 14.5 1.2 17.2 11.8 14.4 1.3 17.2 11.5 0.4 0 0.4 0.4 16 4 10 305 4 0 4 0 -1.4 0.1 -0.6 -1.8 05/14/2005 18:40:00 13.4 1 16.1 10.7 13.4 1.2 16.1 9.5 0.4 0 0.4 0.4 19 5 19 305 4 0 4 0 -1.3 0.1 -0.6 -1.5 05/14/2005 18:50:00 13.8 1 15.6 10.7 13.7 1.1 16.1 11.1 0.4 0 0.4 0.4 21 5 22 305 3 0 4 0 -1.5 0.1 -0.8 -1.8 05/14/2005 19:00:00 14.4 1.2 17.2 11.1 14.3 1.3 17.2 10.7 0.4 0 0.4 0.4 16 4 23 305 3 0 4 0 -1.5 0.1 -0.8 -1.8 05/14/2005 19:10:00 13.1 1 15.3 9.9 13.1 1 15.3 10.7 0.4 0 0.4 0.4 17 4 19 305 4 0 4 0 -1.4 0 -1.1 -1.8 05/14/2005 19:20:00 13.8 1.1 16.1 11.1 13.8 1.2 16.8 10.7 0.4 0 0.4 0.4 10 4 5 305 4 0 4 0 -1.2 0.2 -0.6 -1.8 05/14/2005 19:30:00 14.4 1 16.8 12.2 14.4 1 16.8 11.8 0.4 0 0.4 0.4 9 4 7 305 3 0 3 0 -1.6 0.1 -1.1 -1.8 05/14/2005 19:40:00 14.4 1.1 16.4 11.1 14.3 1.2 16.8 10.7 0.4 0 0.4 0.4 13 3 17 305 4 0 4 0 -1.4 0 -0.8 -1.5 05/14/2005 19:50:00 14.6 0.8 16.4 11.8 14.6 1 16.4 11.5 0.4 0 0.4 0.4 22 4 27 305 4 0 4 0 -1.6 0.1 -0.8 -2 05/14/2005 20:00:00 14.3 1.1 16.4 11.1 14.3 1.1 16.8 11.1 0.4 0 0.4 0.4 22 4 15 305 4 0 4 0 -1.9 0 -1.3 -2 05/14/2005 20:10:00 14.3 1 16.8 11.5 14.2 1.2 17.2 11.8 0.4 0 0.4 0.4 17 4 16 305 4 0 4 0 -2 0 -1.3 -2 05/14/2005 20:20:00 15 1 17.2 12.2 14.9 1.1 17.2 12.2 0.4 0 0.4 0.4 18 4 18 305 4 0 4 0 -2.1 0.1 -1.5 -2.2 05/14/2005 20:30:00 15 1 17.2 12.6 14.9 1.1 17.6 12.2 0.4 0 0.4 0.4 23 4 25 305 4 0 4 0 -2.2 0 -1.8 -2.4 05/14/2005 20:40:00 14.5 1.1 17.2 11.1 14.5 1.2 17.6 11.1 0.4 0 0.4 0.4 22 4 25 305 4 0 4 0 -2.3 0 -1.8 -2.4 05/14/2005 20:50:00 14.5 1.4 17.6 11.1 14.4 1.5 17.9 11.1 0.4 0 0.4 0.4 22 4 22 305 4 0 4 0 -2.3 0 -1.8 -2.7 05/14/2005 21:00:00 15.1 0.9 17.6 11.8 14.9 1 17.2 12.2 0.4 0 0.4 0.4 20 4 22 305 4 0 4 0 -2.5 0 -2.4 -2.7 05/14/2005 21:10:00 15.1 1.1 17.9 11.8 15 1.1 17.2 11.5 0.4 0 0.4 0.4 19 5 19 305 4 0 4 0 -2.6 0 -2.4 -2.7 05/14/2005 21:20:00 16 1.3 18.7 13 15.8 1.4 19.1 12.2 0.4 0 0.4 0.4 19 4 18 305 4 0 4 0 -2.7 0 -2.4 -2.7 05/14/2005 21:30:00 15.4 1.5 18.7 11.5 15.4 1.6 18.7 11.5 0.4 0 0.4 0.4 19 4 18 305 4 0 4 0 -2.8 0 -2.7 -2.9 05/14/2005 21:40:00 15 1.3 17.9 11.1 15 1.4 17.6 10.7 0.4 0 0.4 0.4 20 5 19 305 5 0 5 0 -2.8 0 -2.2 -3.1 05/14/2005 21:50:00 15 1 16.8 12.2 14.8 1.1 17.2 11.8 0.4 0 0.4 0.4 19 4 19 305 5 0 5 0 -2.8 0 -2.7 -3.1 05/14/2005 22:00:00 15 1.2 17.6 11.5 15 1.2 17.9 11.5 0.4 0 0.4 0.4 19 4 18 305 6 0 6 0 -2.8 0 -2.7 -3.1 05/14/2005 22:10:00 14.2 1.2 17.2 11.1 14.2 1.3 17.2 10.7 0.4 0 0.4 0.4 21 5 22 305 6 0 6 0 -3 0 -2.7 -3.3 05/14/2005 22:20:00 14.5 1.2 16.8 11.1 14.5 1.2 17.2 11.1 0.4 0 0.4 0.4 20 4 19 305 7 0 7 0 -3.1 0 -2.9 -3.1 05/14/2005 22:30:00 13.7 1.2 16.4 10.7 13.6 1.3 16.8 10.3 0.4 0 0.4 0.4 21 5 23 305 8 0 7 0 -3.2 0 -3.1 -3.3 05/14/2005 22:40:00 13.8 1.1 16.4 10.3 13.8 1.2 16.4 9.9 0.4 0 0.4 0.4 20 5 23 305 9 0 8 0 -3.2 0 -2.7 -3.3 05/14/2005 22:50:00 14.4 1.2 16.8 11.5 14.2 1.2 17.2 11.1 0.4 0 0.4 0.4 18 4 19 305 10 0 10 0 -3.2 0 -3.1 -3.3 05/14/2005 23:00:00 14 1.5 17.6 10.3 14 1.5 17.2 10.3 0.4 0 0.4 0.4 16 5 19 305 11 0 11 0 -3.3 0 -3.1 -3.3 05/14/2005 23:10:00 15.9 1.1 18.3 11.5 15.7 1.1 17.9 12.2 0.4 0 0.4 0.4 18 4 13 305 12 0 12 0 -3.3 0 -3.1 -3.6 05/14/2005 23:20:00 15.3 1.2 17.9 12.2 15.1 1.2 17.9 11.5 0.4 0 0.4 0.4 17 4 18 305 12 0 12 0 -3.5 0 -3.3 -3.6 05/14/2005 23:30:00 14.5 1.5 17.2 11.1 14.3 1.5 17.6 10.3 0.4 0 0.4 0.4 17 5 21 305 13 0 13 0 -3.5 0 -3.3 -3.8 05/14/2005 23:40:00 14.4 1.5 17.9 9.9 14.2 1.5 17.6 10.3 0.4 0 0.4 0.4 16 5 10 305 14 0 14 0 -3.6 0 -3.3 -3.8 05/14/2005 23:50:00 14 1.3 16.8 9.9 13.7 1.3 16.8 10.3 0.4 0 0.4 0.4 18 6 17 305 15 0 15 0 -3.6 0 -3.3 -3.8 05/15/2005 00:00:00 14.4 1.6 17.6 9.9 14.1 1.7 17.6 10.3 0.4 0 0.4 0.4 19 5 18 305 16 0 15 0 -3.6 0 -3.1 -3.8 05/15/2005 00:10:00 14.1 1.5 16.8 9.5 13.9 1.6 16.8 9.1 0.4 0 0.4 0.4 20 5 24 305 16 0 16 0 -3.6 0 -3.1 -3.8 05/15/2005 00:20:00 14.4 1.2 17.2 11.1 14.1 1.3 16.8 10.3 0.4 0 0.4 0.4 19 5 22 305 16 0 16 0 -3.6 0 -3.3 -3.8 05/15/2005 00:30:00 14 1.1 16.1 11.1 13.7 1.2 16.1 9.5 0.4 0 0.4 0.4 20 5 20 305 17 0 16 0 -3.7 0 -3.6 -3.8 05/15/2005 00:40:00 13.2 1.4 16.8 10.3 13 1.5 16.4 9.5 0.4 0 0.4 0.4 17 6 12 305 17 0 18 0 -3.6 0 -3.3 -3.8 05/15/2005 00:50:00 13.8 1.3 16.8 9.9 13.4 1.4 16.8 9.9 0.4 0 0.4 0.4 14 5 11 305 18 0 18 0 -3.5 0 -3.3 -3.6 05/15/2005 01:00:00 14.7 1.2 17.6 11.1 14.4 1.2 17.2 10.3 0.4 0 0.4 0.4 16 5 22 305 17 0 18 0 -3.5 0 -3.3 -3.6 05/15/2005 01:10:00 14.4 1.2 17.2 11.1 14.1 1.3 16.8 11.1 0.4 0 0.4 0.4 12 5 14 305 17 0 17 0 -3.5 0 -3.3 -3.8 05/15/2005 01:20:00 13.5 1.8 16.8 9.1 13.4 1.7 17.2 9.1 0.4 0 0.4 0.4 9 6 10 305 17 0 17 0 -3.6 0 -3.3 -3.8 05/15/2005 01:30:00 12.7 1.5 15.6 9.1 12.6 1.5 16.1 8.4 0.4 0 0.4 0.4 14 5 17 305 17 0 16 0 -3.7 0 -3.6 -3.8 05/15/2005 01:40:00 13.3 1.3 16.1 9.9 13.1 1.2 16.1 9.5 0.4 0 0.4 0.4 15 5 19 305 17 0 17 0 -3.7 0 -3.6 -3.8 05/15/2005 01:50:00 13.5 1.4 16.4 10.3 13.3 1.5 16.4 10.3 0.4 0 0.4 0.4 15 6 19 305 17 0 17 0 -3.9 0 -3.6 -4 05/15/2005 02:00:00 13.7 1.3 16.4 10.3 13.6 1.3 16.4 9.9 0.4 0 0.4 0.4 13 5 11 305 16 0 16 0 -4 0 -3.8 -4 05/15/2005 02:10:00 13.9 1.2 16.1 9.9 13.6 1.3 16.4 9.9 0.4 0 0.4 0.4 19 5 17 305 16 0 16 0 -4 0 -3.3 -4.2 05/15/2005 02:20:00 13.2 1.3 16.1 9.5 13.1 1.2 16.1 9.9 0.4 0 0.4 0.4 8 6 19 305 17 0 16 0 -4.1 0 -3.8 -4.2 05/15/2005 02:30:00 13.3 1.2 16.1 9.9 13.1 1.2 16.1 9.1 0.4 0 0.4 0.4 7 5 15 305 18 0 18 0 -4.3 0 -4 -4.5 05/15/2005 02:40:00 12.9 1.3 16.1 9.1 12.8 1.3 15.6 9.1 0.4 0 0.4 0.4 8 5 10 305 19 0 18 0 -4.4 0 -4 -4.5 05/15/2005 02:50:00 13.1 1.5 16.1 9.1 13 1.5 16.4 9.1 0.4 0 0.4 0.4 8 5 11 305 19 0 20 0 -4.3 0 -4 -4.5 05/15/2005 03:00:00 13.3 1.5 15.6 8.8 13.3 1.5 16.1 9.1 0.4 0 0.4 0.4 6 5 2 305 20 0 20 0 -4.4 0 -4.2 -4.7 05/15/2005 03:10:00 13.7 1.1 16.1 9.5 13.5 1.2 16.4 9.5 0.4 0 0.4 0.4 10 5 11 305 21 0 21 0 -4.5 0 -4.5 -4.7 05/15/2005 03:20:00 13.1 1.3 16.8 10.3 12.9 1.5 17.2 9.5 0.4 0 0.4 0.4 17 6 26 305 21 0 21 0 -4.4 0 -4.2 -4.7 05/15/2005 03:30:00 12.6 1.4 16.1 9.1 12.4 1.5 16.1 9.1 0.4 0 0.4 0.4 21 6 14 305 21 0 21 0 -4.4 0 -4.2 -4.5 05/15/2005 03:40:00 13.3 1.3 16.1 9.1 13.1 1.4 16.4 9.5 0.4 0 0.4 0.4 21 6 24 305 20 0 20 0 -4.4 0 -4.5 -4.7 05/15/2005 03:50:00 14.1 1.3 16.8 11.1 13.9 1.3 16.4 11.1 0.4 0 0.4 0.4 21 5 26 305 19 0 20 0 -4.6 0 -4.5 -4.7 05/15/2005 04:00:00 13 1.2 15.6 10.3 12.8 1.3 16.1 10.3 0.4 0 0.4 0.4 21 7 23 305 19 0 19 0 -4.5 0 -4.5 -4.7 05/15/2005 04:10:00 12.8 1.2 16.4 10.3 12.7 1.2 15.6 9.1 0.4 0 0.4 0.4 16 7 25 305 19 0 19 0 -4.6 0 -4.5 -4.7 05/15/2005 04:20:00 13 1 15.3 9.9 12.9 1.1 14.9 9.9 0.4 0 0.4 0.4 10 5 10 305 20 0 19 0 -4.7 0 -4.5 -4.7 05/15/2005 04:30:00 13.5 1.1 16.4 9.9 13.5 1.2 16.1 9.9 0.4 0 0.4 0.4 9 5 5 305 20 0 21 0 -4.7 0 -4.5 -4.9 05/15/2005 04:40:00 13.2 1.2 16.1 9.5 13.1 1.3 16.4 9.5 0.4 0 0.4 0.4 9 5 11 305 21 0 21 0 -4.9 0 -4.7 -5.1 05/15/2005 04:50:00 13.5 1.3 16.4 9.9 13.4 1.3 16.4 10.3 0.4 0 0.4 0.4 12 5 4 305 21 0 21 0 -5 0 -4.9 -5.1 05/15/2005 05:00:00 13.8 1.3 16.1 9.9 13.6 1.3 16.4 9.5 0.4 0 0.4 0.4 12 6 9 305 21 0 22 0 -5 0 -4.9 -5.1 05/15/2005 05:10:00 13.5 1.2 16.1 9.5 13.3 1.3 16.4 9.9 0.4 0 0.4 0.4 7 5 7 305 22 0 22 0 -5.2 0 -5.1 -5.3 05/15/2005 05:20:00 13.5 1.2 16.1 9.1 13.4 1.2 16.1 9.9 0.4 0 0.4 0.4 8 5 14 305 22 0 22 0 -5.2 0 -5.1 -5.6 05/15/2005 05:30:00 13 1.2 16.1 9.9 12.9 1.2 15.3 9.9 0.4 0 0.4 0.4 8 5 10 305 22 0 22 0 -5.2 0 -5.1 -5.3 05/15/2005 05:40:00 13.3 1 15.6 10.3 13.2 1 15.6 9.9 0.4 0 0.4 0.4 8 5 10 305 23 0 23 0 -5.1 0 -5.1 -5.3 05/15/2005 05:50:00 12.9 1.1 15.6 10.3 12.9 1.2 15.6 9.1 0.4 0 0.4 0.4 10 5 12 305 23 0 23 0 -5.2 0 -5.1 -5.6 05/15/2005 06:00:00 13 1.1 15.6 10.3 12.8 1.2 16.4 9.5 0.4 0 0.4 0.4 13 7 7 305 23 0 23 0 -5.2 0 -5.1 -5.3 05/15/2005 06:10:00 12.6 1.1 16.1 9.1 12.4 1.2 14.9 8.8 0.4 0 0.4 0.4 17 6 1 305 24 0 23 0 -5.1 0 -4.9 -5.3 05/15/2005 06:20:00 12.7 1.3 15.6 9.1 12.6 1.3 15.3 9.1 0.4 0 0.4 0.4 15 5 15 305 24 0 24 0 -5 0 -4.9 -5.1 05/15/2005 06:30:00 13.6 1.1 16.1 9.9 13.5 1.2 16.1 9.5 0.4 0 0.4 0.4 14 6 12 305 24 0 24 0 -5 0 -4.7 -5.1 05/15/2005 06:40:00 12.6 1.2 15.6 9.5 12.5 1.3 16.1 9.1 0.4 0 0.4 0.4 17 6 25 305 25 0 25 0 -4.7 0 -4.5 -4.9 05/15/2005 06:50:00 13.8 1.2 16.4 9.9 13.7 1.3 16.4 9.9 0.4 0 0.4 0.4 20 5 22 305 23 1 25 0 -4.8 0 -4.7 -4.9 05/15/2005 07:00:00 13.7 1.1 16.1 10.3 13.6 1.2 16.4 10.3 0.4 0 0.4 0.4 21 5 19 305 21 0 21 0 -4.9 0 -4.7 -5.1 05/15/2005 07:10:00 13.6 1.2 15.6 9.9 13.4 1.3 16.1 9.1 0.4 0 0.4 0.4 19 5 19 305 20 0 20 0 -4.9 0 -4.7 -5.1 05/15/2005 07:20:00 13 1 15.6 10.3 12.9 1.1 16.1 9.5 0.4 0 0.4 0.4 21 5 12 305 19 0 19 0 -4.8 0 -4.5 -4.9 05/15/2005 07:30:00 12.3 1.1 14.9 8.8 12.2 1.2 15.3 9.1 0.4 0 0.4 0.4 16 7 27 305 19 0 19 0 -4.9 0.1 -4.5 -5.1 05/15/2005 07:40:00 11.9 1.3 14.9 8.4 11.9 1.4 15.3 8 0.4 0 0.4 0.4 13 6 12 305 19 0 19 0 -5.1 0.1 -4.9 -5.6 05/15/2005 07:50:00 12.6 1.3 15.6 9.1 12.6 1.3 16.4 9.1 0.4 0 0.4 0.4 15 5 14 305 20 0 20 0 -5.3 0.1 -5.1 -5.6 05/15/2005 08:00:00 12.2 0.9 14.5 9.9 12 1.1 14.9 9.1 0.4 0 0.4 0.4 20 5 13 305 20 0 20 0 -5.2 0 -4.9 -5.3 05/15/2005 08:10:00 13 1.3 16.4 9.9 12.9 1.4 16.8 9.1 0.4 0 0.4 0.4 12 5 13 305 21 0 21 0 -5.1 0 -4.9 -5.3 05/15/2005 08:20:00 12.6 1.1 15.6 9.1 12.5 1.2 16.1 9.1 0.4 0 0.4 0.4 16 6 13 305 21 0 21 0 -5.1 0 -4.9 -5.3 05/15/2005 08:30:00 11.8 1 14.5 8.8 11.7 1.1 14.5 8.8 0.4 0 0.4 0.4 16 6 12 305 21 0 21 0 -5 0 -4.7 -5.1 05/15/2005 08:40:00 12.8 1 15.6 10.3 12.8 1.1 16.1 9.9 0.4 0 0.4 0.4 15 5 14 305 21 0 21 0 -4.9 0 -4.7 -5.1 05/15/2005 08:50:00 12.6 0.7 14.1 9.5 12.5 0.8 14.1 9.9 0.4 0 0.4 0.4 22 6 16 305 21 0 21 0 -4.7 0.1 -4.5 -4.9 05/15/2005 09:00:00 12.9 1.1 15.3 9.9 12.6 1.2 15.3 9.9 0.4 0 0.4 0.4 27 5 30 305 20 0 20 0 -4.9 0 -4.7 -5.1 05/15/2005 09:10:00 13.1 1.2 15.6 9.9 13 1.2 15.6 9.9 0.4 0 0.4 0.4 27 5 27 305 19 0 19 0 -5.1 0 -4.7 -5.6 05/15/2005 09:20:00 13.3 0.9 15.3 11.1 13.2 1.1 15.3 10.3 0.4 0 0.4 0.4 29 4 29 305 18 0 18 0 -5.2 0.1 -4.9 -5.6 05/15/2005 09:30:00 13.6 1 16.8 9.9 13.4 1.1 16.1 9.9 0.4 0 0.4 0.4 28 5 29 305 17 0 17 0 -5.2 0 -5.1 -5.6 05/15/2005 09:40:00 13.4 1.3 16.1 10.3 13.3 1.3 16.4 9.9 0.4 0 0.4 0.4 25 5 32 305 16 0 16 0 -5.2 0 -4.9 -5.6 05/15/2005 09:50:00 12.7 1.3 15.6 8.8 12.6 1.5 16.1 8.8 0.4 0 0.4 0.4 28 4 25 305 16 0 16 0 -5.3 0.1 -4.9 -5.6 05/15/2005 10:00:00 12.2 1.2 14.5 9.1 12 1.2 15.3 8.8 0.4 0 0.4 0.4 27 5 33 305 17 0 17 0 -5 0 -4.7 -5.3 05/15/2005 10:10:00 13.3 1.1 15.3 9.9 13.1 1.2 15.6 9.5 0.4 0 0.4 0.4 24 5 23 305 16 0 16 0 -5.1 0 -4.7 -5.3 05/15/2005 10:20:00 12.8 1.2 15.3 9.5 12.7 1.2 15.3 9.5 0.4 0 0.4 0.4 26 5 30 305 16 0 15 0 -5 0 -4.7 -5.1 05/15/2005 10:30:00 12.6 1 15.3 9.9 12.6 1.1 15.3 9.5 0.4 0 0.4 0.4 23 4 29 305 15 0 15 0 -5 0.1 -4.7 -5.3 05/15/2005 10:40:00 11.8 1 14.1 8.8 11.6 1.1 13.7 8.4 0.4 0 0.4 0.4 25 6 37 305 15 0 14 0 -4.6 0.1 -4 -4.9 05/15/2005 10:50:00 12.7 1.1 14.9 9.9 12.5 1.2 15.3 9.9 0.4 0 0.4 0.4 26 5 26 305 14 0 14 0 -4.7 0 -4.5 -4.9 05/15/2005 11:00:00 12.8 0.9 14.5 9.1 12.7 1.1 14.9 8.8 0.4 0 0.4 0.4 19 5 21 305 13 0 13 0 -4.7 0 -4.2 -4.9 05/15/2005 11:10:00 13.1 1 14.9 9.9 13.1 1 14.9 9.5 0.4 0 0.4 0.4 23 5 25 305 13 0 13 0 -4.4 0.2 -4 -4.7 05/15/2005 11:20:00 12.7 1.1 15.3 9.5 12.7 1.2 15.3 9.5 0.4 0 0.4 0.4 18 4 16 305 13 0 13 0 -4.3 0 -4 -4.5 05/15/2005 11:30:00 13 0.9 15.6 10.3 12.9 1 15.6 9.9 0.4 0 0.4 0.4 13 5 10 305 12 0 12 0 -4.4 0 -4 -4.7 05/15/2005 11:40:00 13 1.1 15.6 9.9 13 1.2 16.1 9.1 0.4 0 0.4 0.4 15 5 13 305 13 0 13 0 -4.5 0 -4 -4.7 05/15/2005 11:50:00 12.7 1 15.3 9.9 12.8 1.1 15.6 9.9 0.4 0 0.4 0.4 15 4 18 305 13 0 13 0 -4.4 0.1 -4 -4.7 05/15/2005 12:00:00 12.7 1 14.9 9.9 12.6 1.3 14.9 9.1 0.4 0 0.4 0.4 16 5 359 305 13 0 13 0 -4.1 0.1 -3.3 -4.5 05/15/2005 12:10:00 13.1 1.1 15.3 9.9 12.9 1.2 15.3 9.9 0.4 0 0.4 0.4 22 6 19 305 13 1 14 0 -3.9 0 -3.8 -4.2 05/15/2005 12:20:00 12.8 0.9 14.9 9.9 12.7 1 14.9 9.5 0.4 0 0.4 0.4 23 5 10 305 11 0 11 0 -4.1 0.1 -3.8 -4.5 05/15/2005 12:30:00 13.2 0.8 15.3 10.7 13.1 1 15.6 9.9 0.4 0 0.4 0.4 25 4 23 305 11 0 11 0 -4.2 0 -4 -4.5 05/15/2005 12:40:00 12.9 0.8 15.3 10.3 12.8 1 14.9 9.5 0.4 0 0.4 0.4 23 5 34 305 10 0 10 0 -4.2 0 -4 -4.5 05/15/2005 12:50:00 12.9 1 14.9 9.9 12.8 1.2 14.9 9.1 0.4 0 0.4 0.4 25 5 24 305 9 0 9 0 -4.2 0.1 -3.8 -4.5 05/15/2005 13:00:00 12.8 1.1 15.3 9.9 12.8 1.2 15.3 9.1 0.4 0 0.4 0.4 22 5 20 305 9 0 9 0 -4.3 0 -4 -4.5 05/15/2005 13:10:00 13.3 0.9 14.9 10.7 13.1 1 15.3 9.5 0.4 0 0.4 0.4 24 4 24 305 9 0 9 0 -4.1 0.1 -3.8 -4.5 05/15/2005 13:20:00 13.1 1 15.6 9.9 12.9 1.1 15.3 9.9 0.4 0 0.4 0.4 28 5 28 305 8 0 9 0 -4.1 0.1 -3.8 -4.5 05/15/2005 13:30:00 12.9 1.1 15.3 8.8 12.7 1.1 15.6 9.5 0.4 0 0.4 0.4 23 6 24 305 8 0 8 0 -3.9 0.1 -3.6 -4.5 05/15/2005 13:40:00 13.3 0.9 14.9 10.3 13.2 1 15.3 10.3 0.4 0 0.4 0.4 20 5 19 305 8 0 8 0 -4 0 -3.8 -4.2 05/15/2005 13:50:00 13.1 1.1 16.1 10.3 12.9 1.2 15.3 9.9 0.4 0 0.4 0.4 23 5 15 305 8 0 8 0 -3.7 0.1 -3.3 -4 05/15/2005 14:00:00 13.2 1.1 16.1 9.5 13 1.3 16.4 9.5 0.4 0 0.4 0.4 21 5 23 305 7 0 7 0 -3.6 0.1 -3.1 -3.8 05/15/2005 14:10:00 12.5 1.1 14.9 9.1 12.5 1.2 15.3 9.1 0.4 0 0.4 0.4 16 4 15 305 7 0 7 0 -3.6 0.2 -3.1 -4 05/15/2005 14:20:00 13.1 1.1 15.3 9.5 13.1 1.2 15.6 9.9 0.4 0 0.4 0.4 17 6 11 305 7 0 7 0 -3.8 0.1 -3.3 -4 05/15/2005 14:30:00 13 1 14.9 10.3 12.9 1.1 15.3 9.1 0.4 0 0.4 0.4 24 4 25 305 7 0 7 0 -3.8 0 -3.6 -4 05/15/2005 14:40:00 12.7 1 15.3 9.5 12.6 1.1 14.9 9.5 0.4 0 0.4 0.4 21 6 15 305 7 0 7 0 -3.6 0.2 -3.1 -4 05/15/2005 14:50:00 12.6 1 15.3 9.1 12.5 1.1 16.1 9.5 0.4 0 0.4 0.4 23 5 21 305 6 0 6 0 -3.6 0.2 -3.1 -3.8 05/15/2005 15:00:00 12.6 1.2 15.6 9.5 12.4 1.3 15.6 9.1 0.4 0 0.4 0.4 21 5 15 305 5 0 5 0 -3.5 0.1 -3.1 -3.8 05/15/2005 15:10:00 12.9 1.1 15.3 9.9 12.8 1.2 15.6 9.1 0.4 0 0.4 0.4 17 5 21 305 5 0 5 0 -3.6 0.1 -3.3 -3.8 05/15/2005 15:20:00 13.2 1 15.6 10.3 13.1 1 15.3 10.3 0.4 0 0.4 0.4 18 5 11 305 5 0 5 0 -3.5 0 -3.1 -3.8 05/15/2005 15:30:00 13.1 1.2 15.6 9.9 13 1.3 15.3 9.1 0.4 0 0.4 0.4 17 5 16 305 4 0 4 0 -3.4 0 -3.1 -3.8 05/15/2005 15:40:00 12.9 0.8 14.9 10.7 12.8 0.9 14.9 10.3 0.4 0 0.4 0.4 21 5 20 305 4 0 4 0 -3.3 0 -3.1 -3.6 05/15/2005 15:50:00 12.5 1 14.9 9.1 12.4 1.2 15.6 9.1 0.4 0 0.4 0.4 21 4 21 305 4 0 4 0 -3.3 0 -3.1 -3.6 05/15/2005 16:00:00 13.1 1 14.9 9.9 13 1.1 15.6 9.5 0.4 0 0.4 0.4 20 5 22 305 4 0 4 0 -3.2 0.1 -2.9 -3.6 05/15/2005 16:10:00 12.3 0.8 14.1 10.3 12.3 1 14.9 9.5 0.4 0 0.4 0.4 22 7 16 305 3 0 4 0 -3.2 0.1 -2.9 -3.6 05/15/2005 16:20:00 12.2 1 14.9 9.5 12.1 1.2 15.3 9.1 0.4 0 0.4 0.4 23 5 24 305 3 0 3 0 -3.1 0.1 -2.7 -3.3 05/15/2005 16:30:00 11.8 0.9 13.7 8.8 11.8 1 13.7 9.1 0.4 0 0.4 0.4 23 6 23 305 3 0 3 0 -3.3 0 -2.9 -3.6 05/15/2005 16:40:00 12 0.7 14.1 9.5 12.1 0.8 14.5 9.1 0.4 0 0.4 0.4 19 4 16 305 3 0 2 0 -3.4 0.1 -3.1 -3.8 05/15/2005 16:50:00 12.1 1.1 14.1 9.1 12.1 1.1 14.5 9.5 0.4 0 0.4 0.4 21 6 12 305 3 0 2 0 -3.3 0 -3.1 -3.8 05/15/2005 17:00:00 12 0.9 14.1 9.5 12 1 14.5 9.1 0.4 0 0.4 0.4 19 5 15 305 3 0 2 0 -3.2 0.1 -2.7 -3.3 05/15/2005 17:10:00 12.3 1 14.9 8.8 12.2 1.1 14.5 8.8 0.4 0 0.4 0.4 22 8 13 305 3 0 2 0 -3.1 0.2 -2.7 -3.3 05/15/2005 17:20:00 12.3 1.1 15.3 9.5 12.3 1.2 15.3 9.1 0.4 0 0.4 0.4 24 5 25 305 2 0 2 0 -3.4 0.2 -2.9 -3.8 05/15/2005 17:30:00 13 1.2 15.6 9.5 12.7 1.3 16.1 8.8 0.4 0 0.4 0.4 26 5 32 305 2 0 2 0 -3.5 0.1 -3.1 -3.8 05/15/2005 17:40:00 13 1 15.3 9.9 12.9 1.2 15.6 9.5 0.4 0 0.4 0.4 25 4 25 305 2 0 2 0 -3.7 0.1 -3.3 -4 05/15/2005 17:50:00 13.2 1.1 15.6 9.5 13.2 1.2 16.1 9.9 0.4 0 0.4 0.4 18 5 15 305 2 0 2 0 -3.4 0.2 -3.1 -3.8 05/15/2005 18:00:00 12.6 0.9 14.1 9.1 12.5 1 14.5 8.8 0.4 0 0.4 0.4 22 5 26 305 2 0 2 0 -3.6 0.1 -3.3 -3.8 05/15/2005 18:10:00 13.2 0.9 15.3 10.3 13.1 1 14.9 10.7 0.4 0 0.4 0.4 19 5 25 305 2 0 2 0 -3.7 0.1 -3.3 -3.8 05/15/2005 18:20:00 12.3 1.1 14.1 9.5 12.2 1.2 14.5 9.1 0.4 0 0.4 0.4 20 5 11 305 2 0 2 0 -3.3 0 -3.1 -3.6 05/15/2005 18:30:00 13 1 14.5 9.5 13.1 1 15.3 9.9 0.4 0 0.4 0.4 22 3 22 305 2 0 2 0 -3.5 0 -3.3 -3.8 05/15/2005 18:40:00 13 1 14.9 9.9 12.9 1 15.3 9.9 0.4 0 0.4 0.4 19 5 25 305 2 0 2 0 -3.3 0 -3.1 -3.6 05/15/2005 18:50:00 12.4 1.1 14.9 9.5 12.3 1.2 14.9 9.5 0.4 0 0.4 0.4 21 5 22 305 2 0 2 0 -3.3 0 -3.1 -3.8 05/15/2005 19:00:00 12.4 0.8 14.1 9.5 12.3 1 14.5 9.1 0.4 0 0.4 0.4 24 5 24 305 2 0 2 0 -3.5 0 -3.3 -3.8 05/15/2005 19:10:00 12.1 1 14.5 8.8 11.9 1.1 14.5 9.1 0.4 0 0.4 0.4 20 6 13 305 2 0 2 0 -3.3 0 -2.9 -3.6 05/15/2005 19:20:00 12.3 1.1 14.5 9.1 12.2 1.2 14.9 9.1 0.4 0 0.4 0.4 22 5 24 305 2 0 2 0 -3.3 0 -3.1 -3.6 05/15/2005 19:30:00 12.1 1 13.7 9.1 12 1.1 14.1 8.8 0.4 0 0.4 0.4 21 4 11 305 2 0 2 0 -3.5 0 -3.1 -3.8 05/15/2005 19:40:00 12.4 1.2 14.9 9.5 12.4 1.3 14.9 8.4 0.4 0 0.4 0.4 21 6 19 305 2 0 2 0 -3.5 0 -3.3 -3.8 05/15/2005 19:50:00 11.7 0.9 13.7 9.5 11.6 1 13.7 8 0.4 0 0.4 0.4 20 5 17 305 2 0 2 0 -3.5 0 -3.3 -3.8 05/15/2005 20:00:00 12.9 1.1 15.3 9.9 12.9 1.1 15.6 9.9 0.4 0 0.4 0.4 19 4 13 305 2 0 2 0 -3.5 0 -2.9 -3.8 05/15/2005 20:10:00 12.2 1 14.5 9.1 12.2 1 14.5 8.8 0.4 0 0.4 0.4 23 5 22 305 2 0 2 0 -3.6 0.1 -3.1 -3.8 05/15/2005 20:20:00 11.7 1 13.7 9.1 11.8 1 14.1 9.5 0.4 0 0.4 0.4 20 5 19 305 2 0 2 0 -3.6 0 -3.3 -3.8 05/15/2005 20:30:00 12.2 0.9 14.1 9.9 12 1 14.1 8.8 0.4 0 0.4 0.4 20 5 21 305 2 0 2 0 -3.7 0 -3.6 -3.8 05/15/2005 20:40:00 11.8 1.2 14.5 8.4 11.7 1.3 14.5 7.6 0.4 0 0.4 0.4 21 5 20 305 2 0 2 0 -3.5 0 -3.3 -3.8 05/15/2005 20:50:00 12.5 1 14.5 10.3 12.5 1 14.5 9.5 0.4 0 0.4 0.4 19 4 27 305 2 0 2 0 -3.6 0.1 -3.3 -3.8 05/15/2005 21:00:00 12.6 1 14.9 9.9 12.6 1.1 14.9 9.5 0.4 0 0.4 0.4 21 5 22 305 2 0 2 0 -3.6 0 -3.3 -3.8 05/15/2005 21:10:00 13 1.1 15.6 9.5 12.8 1.2 15.6 9.1 0.4 0 0.4 0.4 21 5 23 305 2 0 2 0 -3.7 0 -3.3 -3.8 05/15/2005 21:20:00 12.8 1.1 14.9 9.9 12.7 1.2 15.6 9.1 0.4 0 0.4 0.4 22 4 23 305 2 0 2 0 -3.9 0 -3.8 -4 05/15/2005 21:30:00 12.7 1 15.3 9.5 12.6 1.2 14.9 8.8 0.4 0 0.4 0.4 22 5 24 305 3 0 2 0 -3.9 0 -3.8 -4 05/15/2005 21:40:00 11.6 1.2 14.5 8.4 11.5 1.3 14.5 8.4 0.4 0 0.4 0.4 24 7 22 305 3 0 3 0 -3.9 0 -3.8 -4 05/15/2005 21:50:00 11.7 1.1 14.9 8.4 11.6 1.2 14.9 8 0.4 0 0.4 0.4 20 7 19 305 4 0 4 0 -4 0 -3.6 -4 05/15/2005 22:00:00 12.4 1.2 14.5 9.1 12.3 1.2 14.9 9.1 0.4 0 0.4 0.4 19 5 19 305 4 0 4 0 -4 0 -3.8 -4 05/15/2005 22:10:00 11.2 1 13.7 8.8 11.1 1 13.3 8.8 0.4 0 0.4 0.4 28 5 26 305 5 0 5 0 -4.2 0.1 -3.8 -4.5 05/15/2005 22:20:00 11.9 1 14.1 9.1 11.7 1.1 13.7 8.8 0.4 0 0.4 0.4 26 6 24 305 6 0 6 0 -4.2 0 -4 -4.5 05/15/2005 22:30:00 11.4 1 13.7 8.8 11.3 1.2 14.1 8 0.4 0 0.4 0.4 26 5 30 305 7 0 7 0 -4.4 0 -3.8 -4.7 05/15/2005 22:40:00 11.8 0.9 14.5 8.8 11.9 1 14.1 8 0.4 0 0.4 0.4 22 5 18 305 9 1 8 0 -4.4 0 -4.2 -4.5 05/15/2005 22:50:00 11.5 1 14.1 9.1 11.5 1 14.1 8.4 0.4 0 0.4 0.4 24 5 20 305 11 0 11 0 -4.4 0 -4.2 -4.7 05/15/2005 23:00:00 11.4 0.9 13.3 8.8 11.3 1 13.3 8.4 0.4 0 0.4 0.4 25 6 22 305 12 0 12 0 -4.4 0 -4.2 -4.7 05/15/2005 23:10:00 11.5 0.7 13.3 8.8 11.4 0.8 13.3 9.1 0.4 0 0.4 0.4 24 5 30 305 14 0 13 0 -4.5 0 -4.5 -4.7 05/15/2005 23:20:00 11.6 0.8 13.3 9.1 11.5 0.9 13.7 8.8 0.4 0 0.4 0.4 27 5 26 305 14 0 14 0 -4.7 0 -4.5 -4.9 05/15/2005 23:30:00 11.6 1 14.1 9.1 11.5 1 13.7 8.8 0.4 0 0.4 0.4 27 5 23 305 15 0 15 0 -4.7 0 -4.5 -4.7 05/15/2005 23:40:00 12 1 14.1 8.8 11.9 1.1 14.1 8.8 0.4 0 0.4 0.4 26 5 17 305 16 0 16 0 -4.9 0 -4.7 -4.9 05/15/2005 23:50:00 11.6 1.1 13.7 8.8 11.4 1.1 14.1 8.8 0.4 0 0.4 0.4 26 5 21 305 16 0 16 0 -4.9 0 -4.7 -5.1 05/16/2005 00:00:00 11.1 1.1 14.5 8.8 11 1.2 14.9 8 0.4 0 0.4 0.4 26 5 23 305 17 0 16 0 -5 0 -4.5 -5.1 05/16/2005 00:10:00 12.2 1 14.5 9.1 12 1 14.1 9.1 0.4 0 0.4 0.4 27 5 32 305 17 0 17 0 -5 0 -4.9 -5.1 05/16/2005 00:20:00 11.9 1 13.7 8.4 11.8 1.1 14.1 8.4 0.4 0 0.4 0.4 23 6 23 305 17 0 17 0 -5.1 0 -4.9 -5.1 05/16/2005 00:30:00 11.2 1.4 13.7 7.6 11 1.4 13.7 7.2 0.4 0 0.4 0.4 22 5 19 305 18 0 18 0 -5.1 0 -4.9 -5.3 05/16/2005 00:40:00 11.3 1 13.7 8 11.1 1 13.7 8 0.4 0 0.4 0.4 22 5 19 305 18 0 18 0 -5.1 0 -4.9 -5.1 05/16/2005 00:50:00 11.3 1 14.5 8.8 11.2 1.2 14.5 8.4 0.4 0 0.4 0.4 19 6 25 305 18 0 18 0 -5.2 0 -5.1 -5.3 05/16/2005 01:00:00 11.4 1.1 14.1 8.4 11.3 1.2 13.7 8.4 0.4 0 0.4 0.4 19 6 22 305 18 0 18 0 -5.2 0 -5.1 -5.6 05/16/2005 01:10:00 11 1 13.3 8.4 10.9 1 13.3 8 0.4 0 0.4 0.4 19 5 24 305 18 0 18 0 -5.2 0 -5.1 -5.3 05/16/2005 01:20:00 11.5 1 13.3 8 11.4 0.9 13.3 8.8 0.4 0 0.4 0.4 23 5 22 305 19 0 18 0 -5.1 0 -5.1 -5.3 05/16/2005 01:30:00 10.4 1 13 8 10.1 1 12.6 8 0.4 0 0.4 0.4 19 5 21 305 19 0 19 0 -5.1 0 -4.9 -5.1 05/16/2005 01:40:00 10.2 1 13 7.6 10.1 1 12.6 8 0.4 0 0.4 0.4 22 6 21 305 19 0 19 0 -5 0 -4.9 -5.1 05/16/2005 01:50:00 11.3 1.2 13.7 8 11.2 1.3 14.1 7.6 0.4 0 0.4 0.4 23 6 26 305 19 0 19 0 -5.1 0 -4.9 -5.1 05/16/2005 02:00:00 11.6 1.4 15.3 8.4 11.4 1.5 15.3 8 0.4 0 0.4 0.4 18 6 21 305 19 0 19 0 -5.1 0 -4.9 -5.3 05/16/2005 02:10:00 12.5 1.2 15.3 8.8 12.4 1.4 16.1 9.1 0.4 0 0.4 0.4 11 4 3 305 18 0 18 0 -5 0 -4.9 -5.1 05/16/2005 02:20:00 11.7 1.1 14.1 8.4 11.6 1.1 14.1 8.4 0.4 0 0.4 0.4 10 6 5 305 18 0 18 0 -4.9 0 -4.7 -5.1 05/16/2005 02:30:00 11.9 1.2 14.9 8.8 11.9 1.3 15.6 8.8 0.4 0 0.4 0.4 11 6 12 305 18 0 18 0 -5 0 -4.9 -5.1 05/16/2005 02:40:00 11.7 1.2 14.9 8.4 11.5 1.2 14.9 8 0.4 0 0.4 0.4 11 5 8 305 18 0 18 0 -5.1 0 -4.9 -5.1 05/16/2005 02:50:00 11.3 1.4 14.1 8 11.3 1.3 14.5 8 0.4 0 0.4 0.4 15 6 11 305 18 0 18 0 -5.1 0 -4.9 -5.3 05/16/2005 03:00:00 11.5 1.2 14.5 8.4 11.5 1.1 14.5 8.4 0.4 0 0.4 0.4 12 5 9 305 18 0 18 0 -5.2 0 -4.9 -5.3 05/16/2005 03:10:00 11.6 1.2 14.9 7.2 11.6 1.1 14.5 8 0.4 0 0.4 0.4 13 5 5 305 18 0 18 0 -5.1 0 -4.9 -5.3 05/16/2005 03:20:00 11.4 1.2 14.5 8.8 11.4 1.2 14.1 8.4 0.4 0 0.4 0.4 12 6 11 305 18 0 18 0 -5.1 0 -4.9 -5.3 05/16/2005 03:30:00 11.4 1.4 14.5 7.6 11.2 1.4 14.9 7.2 0.4 0 0.4 0.4 12 6 14 305 18 0 18 0 -5.2 0 -5.1 -5.3 05/16/2005 03:40:00 11.7 1.1 14.1 8.8 11.7 1.1 14.5 8.8 0.4 0 0.4 0.4 10 7 14 305 19 0 19 0 -5.3 0 -5.1 -5.6 05/16/2005 03:50:00 11.4 1.4 14.1 8 11.3 1.5 14.5 7.2 0.4 0 0.4 0.4 11 7 12 305 19 0 19 0 -5.3 0 -5.1 -5.6 05/16/2005 04:00:00 11.1 1.3 14.5 7.6 11 1.3 14.9 7.6 0.4 0 0.4 0.4 20 7 18 305 19 0 19 0 -5.3 0 -5.1 -5.6 05/16/2005 04:10:00 11.5 1 14.1 9.1 11.3 1.1 14.1 9.1 0.4 0 0.4 0.4 24 6 27 305 18 0 19 0 -5.3 0 -5.1 -5.6 05/16/2005 04:20:00 11.3 1.3 14.5 8.4 11.2 1.3 13.7 8 0.4 0 0.4 0.4 12 6 10 305 18 0 18 0 -5.3 0.1 -5.1 -5.6 05/16/2005 04:30:00 11.1 1.1 13.3 8 11.1 1.1 13.3 8 0.4 0 0.4 0.4 13 6 6 305 18 0 18 0 -5.5 0 -5.3 -5.6 05/16/2005 04:40:00 10.8 1.1 13.3 8.4 10.8 1.3 14.1 7.6 0.4 0 0.4 0.4 14 6 15 305 19 0 19 0 -5.3 0 -5.1 -5.6 05/16/2005 04:50:00 10.8 1.3 13.7 8 10.8 1.3 14.1 7.6 0.4 0 0.4 0.4 17 6 19 305 20 0 19 0 -5.3 0 -5.1 -5.6 05/16/2005 05:00:00 11.9 1 14.1 8.8 11.8 1 13.7 9.1 0.4 0 0.4 0.4 26 6 17 305 19 0 20 0 -5.6 0 -5.3 -5.8 05/16/2005 05:10:00 11.6 1.6 14.9 8 11.4 1.6 14.9 8 0.4 0 0.4 0.4 24 6 30 305 19 0 18 0 -5.6 0 -5.6 -5.8 05/16/2005 05:20:00 12.6 1.3 15.3 8.8 12.5 1.3 15.3 8.8 0.4 0 0.4 0.4 21 5 19 305 17 0 18 0 -5.7 0 -5.6 -5.8 05/16/2005 05:30:00 12.2 1.2 14.9 8.4 11.9 1.3 14.5 7.6 0.4 0 0.4 0.4 22 6 24 305 16 0 16 0 -5.7 0 -5.6 -5.8 05/16/2005 05:40:00 11.7 1.2 14.1 8.4 11.4 1.2 14.1 8.8 0.4 0 0.4 0.4 19 6 14 305 16 0 16 0 -5.7 0 -5.6 -5.8 05/16/2005 05:50:00 11.8 1.2 14.1 8 11.7 1.1 14.1 8 0.4 0 0.4 0.4 21 6 23 305 16 0 16 0 -5.6 0 -5.6 -5.8 05/16/2005 06:00:00 11.3 1.1 13.7 8 11.1 1.2 13.7 8 0.4 0 0.4 0.4 23 6 28 305 15 0 15 0 -5.6 0 -5.1 -5.8 05/16/2005 06:10:00 11.8 1.2 14.1 8.4 11.6 1.3 14.5 8.8 0.4 0 0.4 0.4 26 5 25 305 15 0 15 0 -5.7 0 -5.6 -5.8 05/16/2005 06:20:00 11.3 1.1 13.7 8 11.3 1.1 13.7 8.4 0.4 0 0.4 0.4 23 5 21 305 15 0 15 0 -5.6 0 -5.6 -5.8 05/16/2005 06:30:00 11.5 1.1 13.7 8.4 11.4 1.2 13.7 8 0.4 0 0.4 0.4 13 6 13 305 16 0 15 0 -5.5 0 -5.1 -5.6 05/16/2005 06:40:00 11.9 1 14.1 9.1 11.8 1.1 14.5 9.1 0.4 0 0.4 0.4 10 6 10 305 17 0 17 0 -5.5 0 -5.3 -5.6 05/16/2005 06:50:00 11.8 1.1 14.5 8.4 11.6 1.1 14.1 8.4 0.4 0 0.4 0.4 10 6 9 305 18 0 18 0 -5.5 0 -5.1 -5.8 05/16/2005 07:00:00 11.6 1.1 14.1 8.8 11.5 1.1 14.1 8.8 0.4 0 0.4 0.4 12 7 16 305 18 0 18 0 -5.3 0 -5.1 -5.6 05/16/2005 07:10:00 11.6 1 13.7 9.1 11.4 1.1 13.7 8 0.4 0 0.4 0.4 25 6 26 305 19 0 19 0 -5.5 0 -5.1 -5.8 05/16/2005 07:20:00 11.7 1.3 14.9 8 11.7 1.3 14.9 8 0.4 0 0.4 0.4 23 6 18 305 19 0 19 0 -5.6 0 -5.6 -5.8 05/16/2005 07:30:00 12.6 1.3 15.6 8.8 12.3 1.4 15.3 7.6 0.4 0 0.4 0.4 19 5 23 305 18 0 18 0 -5.8 0 -5.6 -6 05/16/2005 07:40:00 11.9 1 13.7 8.8 11.7 1 13.7 9.1 0.4 0 0.4 0.4 23 5 17 305 17 0 17 0 -5.7 0 -5.6 -5.8 05/16/2005 07:50:00 11.9 1 14.1 9.1 11.8 1.1 14.5 9.1 0.4 0 0.4 0.4 21 6 18 305 17 0 17 0 -5.6 0 -5.6 -5.8 05/16/2005 08:00:00 11.3 1.3 14.5 8 11.3 1.3 14.9 8 0.4 0 0.4 0.4 26 6 27 305 17 0 17 0 -5.6 0 -5.6 -5.8 05/16/2005 08:10:00 11.8 0.8 14.1 8.8 11.6 1 14.1 8.8 0.4 0 0.4 0.4 22 5 19 305 16 0 16 0 -5.7 0 -5.6 -5.8 05/16/2005 08:20:00 11.1 1.2 13.7 8 10.9 1.2 13.3 8 0.4 0 0.4 0.4 24 5 28 305 16 0 16 0 -5.7 0 -5.6 -5.8 05/16/2005 08:30:00 10.6 1.2 13.7 7.6 10.4 1.2 13.3 7.2 0.4 0 0.4 0.4 28 7 22 305 16 0 16 0 -5.6 0 -5.6 -5.8 05/16/2005 08:40:00 9.9 1.4 13 6.5 9.8 1.4 13 6.5 0.4 0 0.4 0.4 25 6 25 305 16 0 16 0 -5.5 0 -5.3 -5.8 05/16/2005 08:50:00 10.7 1.2 13 7.6 10.6 1.2 13 7.2 0.4 0 0.4 0.4 23 6 25 305 16 0 16 0 -5.5 0 -5.3 -5.8 05/16/2005 09:00:00 11.1 1.4 15.6 8.4 11.1 1.4 15.6 8.4 0.4 0 0.4 0.4 21 9 16 305 15 0 15 0 -5.4 0 -5.1 -5.6 05/16/2005 09:10:00 10.1 1 12.2 7.6 10 1.1 12.6 7.2 0.4 0 0.4 0.4 23 8 24 305 15 0 15 0 -5.3 0 -5.1 -5.6 05/16/2005 09:20:00 11.4 1.3 14.9 8.4 11.2 1.3 14.9 8 0.4 0 0.4 0.4 18 6 21 305 14 0 15 0 -5.2 0 -5.1 -5.6 05/16/2005 09:30:00 10.4 1.1 13.3 7.6 10.4 1.1 13.7 8 0.4 0 0.4 0.4 11 6 14 305 14 0 14 0 -5.1 0 -4.9 -5.3 05/16/2005 09:40:00 11.3 1 13.3 8 11.2 1 13.3 8 0.4 0 0.4 0.4 12 6 13 305 14 0 14 0 -5.2 0 -4.9 -5.6 05/16/2005 09:50:00 10.9 1.2 13.3 7.6 10.9 1.3 13.7 7.6 0.4 0 0.4 0.4 11 5 16 305 14 0 14 0 -5.3 0 -4.7 -5.6 05/16/2005 10:00:00 10.7 1.1 13.7 7.6 10.6 1.2 13.7 7.6 0.4 0 0.4 0.4 12 6 11 305 14 0 14 0 -5.3 0 -4.7 -5.6 05/16/2005 10:10:00 10.4 1.1 13 8 10.4 1.1 13 8 0.4 0 0.4 0.4 13 6 23 305 14 0 14 0 -5.1 0 -4.9 -5.6 05/16/2005 10:20:00 11 1.1 13.3 8.4 11 1.2 13.7 8.4 0.4 0 0.4 0.4 11 6 11 305 14 0 14 0 -5.3 0.1 -4.9 -5.6 05/16/2005 10:30:00 10.5 1.1 13 7.6 10.6 1.1 13 7.6 0.4 0 0.4 0.4 11 5 8 305 13 0 13 0 -5.4 0 -5.1 -5.6 05/16/2005 10:40:00 10.6 1.3 13.3 6.5 10.6 1.3 13.3 6.8 0.4 0 0.4 0.4 13 6 10 305 13 0 13 0 -5.2 0 -4.7 -5.6 05/16/2005 10:50:00 10.3 1.1 13.3 7.6 10.4 1.1 13.3 7.6 0.4 0 0.4 0.4 11 6 14 305 12 0 12 0 -5.2 0 -5.1 -5.6 05/16/2005 11:00:00 10.5 1.1 13.3 7.6 10.4 1.2 13 8 0.4 0 0.4 0.4 12 6 13 305 12 0 12 0 -5.3 0 -4.7 -5.6 05/16/2005 11:10:00 11.2 1 13.3 8.8 11.3 1.1 13.7 8.8 0.4 0 0.4 0.4 13 6 25 305 12 0 12 0 -5.5 0 -5.1 -5.8 05/16/2005 11:20:00 11.7 1.1 13.7 8.8 11.7 1.1 14.1 8.8 0.4 0 0.4 0.4 10 5 5 305 11 0 11 0 -5.7 0.1 -5.6 -6 05/16/2005 11:30:00 10.9 1 13.3 7.6 10.9 1 13.7 8 0.4 0 0.4 0.4 13 6 15 305 11 0 11 0 -5.5 0 -4.9 -5.6 05/16/2005 11:40:00 11 1.2 13.7 7.6 11 1.2 13.7 7.6 0.4 0 0.4 0.4 15 6 8 305 11 0 11 0 -5.4 0.1 -5.1 -5.6 05/16/2005 11:50:00 10.8 1.2 13.3 7.6 10.8 1.2 13.3 8 0.4 0 0.4 0.4 16 5 12 305 11 0 11 0 -5.1 0.1 -4.7 -5.6 05/16/2005 12:00:00 10.8 1.2 13.3 7.6 10.9 1.2 13.7 8 0.4 0 0.4 0.4 13 6 12 305 10 0 11 0 -5.3 0 -5.1 -5.6 05/16/2005 12:10:00 11.4 1.2 13.7 8 11.4 1.2 14.1 8.4 0.4 0 0.4 0.4 15 6 12 305 10 0 10 0 -5.2 0 -4.9 -5.6 05/16/2005 12:20:00 10.7 1.1 13.3 8 10.7 1.2 14.1 8 0.4 0 0.4 0.4 14 6 12 305 10 0 10 0 -4.7 0.1 -4.5 -5.1 05/16/2005 12:30:00 11.4 1.1 14.1 8.4 11.3 1.1 14.1 7.6 0.4 0 0.4 0.4 20 5 18 305 10 0 10 0 -4.6 0.1 -4.5 -4.9 05/16/2005 12:40:00 11.4 1 14.1 8 11.3 1.1 14.1 7.2 0.4 0 0.4 0.4 17 5 18 305 9 0 9 0 -4.4 0.2 -4 -4.7 05/16/2005 12:50:00 11.1 1 13 8 11 1.1 13.3 8 0.4 0 0.4 0.4 15 5 14 305 8 0 8 0 -4.4 0 -4.2 -4.7 05/16/2005 13:00:00 11 1.1 13.7 7.6 11.1 1.2 13.7 8 0.4 0 0.4 0.4 16 7 7 305 8 0 8 0 -4.4 0 -4.2 -4.7 05/16/2005 13:10:00 11.1 1.2 14.1 8.4 11.1 1.3 14.5 6.8 0.4 0 0.4 0.4 14 7 7 305 8 0 7 0 -4.4 0.1 -4 -4.7 05/16/2005 13:20:00 11.3 1.2 14.1 8.4 11.3 1.2 14.5 8 0.4 0 0.4 0.4 17 6 10 305 7 0 7 0 -4.5 0.1 -4.2 -4.7 05/16/2005 13:30:00 10.8 1.3 13.3 7.6 10.8 1.3 13.3 7.2 0.4 0 0.4 0.4 12 6 1 305 7 0 7 0 -4.2 0.1 -3.8 -4.5 05/16/2005 13:40:00 10.8 1.3 13.7 7.6 10.8 1.4 14.1 7.2 0.4 0 0.4 0.4 10 6 16 305 7 0 6 0 -4 0 -3.8 -4.2 05/16/2005 13:50:00 11.1 1.2 14.1 8 11.1 1.1 14.1 8 0.4 0 0.4 0.4 12 6 16 305 6 0 6 0 -4 0 -3.8 -4.2 05/16/2005 14:00:00 10.6 1.2 13.3 7.6 10.6 1.2 13.3 7.2 0.4 0 0.4 0.4 8 6 1 305 5 0 6 0 -4 0 -3.8 -4.2 05/16/2005 14:10:00 10.8 1 13 7.6 10.9 1 13.3 8.4 0.4 0 0.4 0.4 6 5 11 305 5 0 5 0 -3.8 0 -3.6 -4 05/16/2005 14:20:00 10.2 1.3 13 6.8 10.1 1.3 13.3 6.8 0.4 0 0.4 0.4 3 6 7 305 5 0 5 0 -3.6 0.1 -3.3 -4 05/16/2005 14:30:00 11 1.4 13.7 7.2 11 1.3 14.1 8 0.4 0 0.4 0.4 6 5 15 305 5 0 5 0 -3.8 0.1 -3.3 -4 05/16/2005 14:40:00 10.7 1 13 8.4 10.7 1.1 13.3 7.2 0.4 0 0.4 0.4 6 6 5 305 4 0 4 0 -3.7 0.1 -3.3 -4 05/16/2005 14:50:00 10.5 1.3 13.3 6.1 10.5 1.3 13 6.5 0.4 0 0.4 0.4 5 6 7 305 4 0 4 0 -3.5 0 -3.1 -3.8 05/16/2005 15:00:00 10.7 1.5 13.7 7.2 10.7 1.5 13.7 7.2 0.4 0 0.4 0.4 9 6 13 305 4 0 4 0 -3.5 0.1 -2.9 -3.8 05/16/2005 15:10:00 10.6 1 13 7.2 10.7 1.1 13.3 8 0.4 0 0.4 0.4 8 6 7 305 3 0 4 0 -3.4 0 -3.1 -3.8 05/16/2005 15:20:00 10.6 1.1 13 8 10.6 1.2 13.3 7.6 0.4 0 0.4 0.4 6 5 3 305 3 0 2 0 -3.4 0.1 -3.1 -3.8 05/16/2005 15:30:00 10.3 1.4 13 6.8 10.5 1.5 13.3 7.2 0.4 0 0.4 0.4 4 6 4 305 2 0 2 0 -3.2 0 -3.1 -3.6 05/16/2005 15:40:00 10.5 1.1 13 7.2 10.6 1.2 13.3 8 0.4 0 0.4 0.4 6 6 9 305 2 0 2 0 -3.3 0 -3.1 -3.6 05/16/2005 15:50:00 10.8 1 13 7.6 10.7 1.1 13 7.2 0.4 0 0.4 0.4 8 5 14 305 2 0 2 0 -3.2 0 -2.9 -3.3 05/16/2005 16:00:00 10.6 1.1 13.3 8 10.5 1.1 13 7.6 0.4 0 0.4 0.4 5 6 7 305 2 0 2 0 -3.1 0 -2.9 -3.3 05/16/2005 16:10:00 10.8 1.1 13.3 7.6 10.7 1.2 13.3 7.6 0.4 0 0.4 0.4 10 6 6 305 2 0 2 0 -3 0 -2.7 -3.1 05/16/2005 16:20:00 10.4 1.2 13 7.2 10.4 1.2 13.3 6.8 0.4 0 0.4 0.4 5 6 354 305 1 0 1 0 -3 0 -2.4 -3.1 05/16/2005 16:30:00 10.7 1 13 8 10.8 1 13.3 8 0.4 0 0.4 0.4 7 5 2 305 1 0 1 0 -2.9 0 -2.7 -3.1 05/16/2005 16:40:00 10.3 1 12.6 7.2 10.4 1.1 13 6.8 0.4 0 0.4 0.4 7 5 4 305 1 0 1 0 -2.9 0.1 -2.4 -3.3 05/16/2005 16:50:00 11 1 13 8.8 11 1 13.3 7.6 0.4 0 0.4 0.4 7 4 4 305 1 0 1 0 -3.1 0.1 -2.7 -3.3 05/16/2005 17:00:00 10.4 1.2 13 7.2 10.3 1.3 13 6.5 0.4 0 0.4 0.4 6 6 2 305 1 0 1 0 -2.9 0.1 -2.7 -3.3 05/16/2005 17:10:00 10 1.2 12.6 7.2 10.1 1.1 12.6 7.6 0.4 0 0.4 0.4 8 6 2 305 1 0 1 0 -2.9 0.1 -2.7 -3.1 05/16/2005 17:20:00 10.2 1 12.2 7.2 10.3 1 12.6 7.6 0.4 0 0.4 0.4 6 6 8 305 1 0 1 0 -3 0 -2.7 -3.3 05/16/2005 17:30:00 10.5 1.3 13 6.5 10.5 1.3 13.3 6.8 0.4 0 0.4 0.4 6 5 4 305 1 0 1 0 -3 0.1 -2.7 -3.3 05/16/2005 17:40:00 10.1 1.1 13 7.6 10.1 1 13 7.6 0.4 0 0.4 0.4 4 5 6 305 1 0 1 0 -3.1 0.1 -2.7 -3.3 05/16/2005 17:50:00 9.9 1 12.2 7.6 9.9 1.1 12.2 7.2 0.4 0 0.4 0.4 2 5 359 305 1 0 1 0 -3.1 0.2 -2.7 -3.3 05/16/2005 18:00:00 9.9 1 12.2 6.5 9.8 1.1 12.6 7.2 0.4 0 0.4 0.4 4 5 6 305 1 0 1 0 -3.1 0.1 -2.7 -3.3 05/16/2005 18:10:00 9.5 1.2 11.5 6.1 9.6 1.1 11.5 6.1 0.4 0 0.4 0.4 1 6 12 305 1 0 1 0 -3.1 0 -2.9 -3.3 05/16/2005 18:20:00 10 1 11.8 7.2 10 1.1 12.2 7.2 0.4 0 0.4 0.4 1 5 0 305 1 0 1 0 -3.2 0 -2.9 -3.3 05/16/2005 18:30:00 9.5 1 11.8 7.2 9.6 1 11.8 6.8 0.4 0 0.4 0.4 5 5 12 305 1 0 1 0 -3.1 0.1 -2.9 -3.3 05/16/2005 18:40:00 9.3 1.1 11.5 6.1 9.2 1.1 11.8 6.5 0.4 0 0.4 0.4 2 5 354 305 1 0 1 0 -3.2 0.1 -2.9 -3.3 05/16/2005 18:50:00 8.9 1 11.8 6.5 9.1 1 12.2 6.5 0.4 0 0.4 0.4 359 6 5 305 1 0 1 0 -3.1 0.1 -2.7 -3.3 05/16/2005 19:00:00 8.6 1.2 11.1 5.3 8.6 1.2 11.5 5.7 0.4 0 0.4 0.4 1 6 358 305 1 0 1 0 -3.2 0.1 -2.7 -3.3 05/16/2005 19:10:00 9.2 1 11.1 6.5 9.2 1 11.1 6.5 0.4 0 0.4 0.4 0 5 0 305 1 0 1 0 -3.3 0 -3.1 -3.3 05/16/2005 19:20:00 9.4 0.9 11.5 7.2 9.5 1 11.8 7.2 0.4 0 0.4 0.4 3 5 6 305 1 0 1 0 -3.3 0 -3.1 -3.3 05/16/2005 19:30:00 8.9 1 11.5 6.1 9 1.1 11.1 5.7 0.4 0 0.4 0.4 2 6 3 305 1 0 1 0 -3.3 0 -2.7 -3.6 05/16/2005 19:40:00 8.8 1 11.1 6.1 8.7 1.1 11.1 6.1 0.4 0 0.4 0.4 4 6 0 305 1 0 1 0 -3.3 0 -3.1 -3.6 05/16/2005 19:50:00 8.9 1 11.1 6.1 8.9 1.1 11.8 6.5 0.4 0 0.4 0.4 4 5 4 305 1 0 1 0 -3.3 0 -2.7 -3.3 05/16/2005 20:00:00 8.8 1.1 11.1 6.1 8.8 1.2 11.5 6.5 0.4 0 0.4 0.4 2 5 1 305 1 0 1 0 -3.5 0.1 -2.7 -3.8 05/16/2005 20:10:00 8.9 0.9 11.1 6.1 8.9 0.9 10.7 6.1 0.4 0 0.4 0.4 3 6 8 305 1 0 1 0 -3.5 0 -2.9 -3.8 05/16/2005 20:20:00 8.6 0.9 10.7 6.5 8.5 0.9 10.7 6.1 0.4 0 0.4 0.4 3 5 2 305 1 0 1 0 -3.6 0 -2.9 -3.8 05/16/2005 20:30:00 8.5 0.8 10.3 6.1 8.6 0.9 10.7 6.5 0.4 0 0.4 0.4 1 5 357 305 1 0 1 0 -3.6 0 -3.3 -3.8 05/16/2005 20:40:00 8.2 0.8 10.7 6.1 8.2 0.9 10.7 6.1 0.4 0 0.4 0.4 0 6 3 305 1 0 1 0 -3.6 0 -3.3 -3.8 05/16/2005 20:50:00 7.9 1 9.9 5.3 7.9 1 10.3 4.9 0.4 0 0.4 0.4 2 5 0 305 1 0 1 0 -3.6 0 -3.3 -3.8 05/16/2005 21:00:00 8.6 0.9 10.3 6.1 8.6 1 10.7 5.7 0.4 0 0.4 0.4 1 5 6 305 1 0 1 0 -3.7 0 -3.6 -3.8 05/16/2005 21:10:00 8.9 0.8 10.7 6.5 9 0.8 10.7 6.8 0.4 0 0.4 0.4 3 4 13 305 1 0 1 0 -3.9 0 -3.6 -4 05/16/2005 21:20:00 8.1 0.8 9.9 6.1 8.1 0.8 10.3 6.5 0.4 0 0.4 0.4 3 6 13 305 1 0 1 0 -3.9 0 -3.3 -4 05/16/2005 21:30:00 8.2 0.9 10.3 5.7 8.3 0.9 10.3 6.1 0.4 0 0.4 0.4 4 5 2 305 1 0 1 0 -4 0 -3.8 -4 05/16/2005 21:40:00 8.3 1 10.3 6.1 8.4 0.9 10.7 5.7 0.4 0 0.4 0.4 1 5 2 305 1 0 1 0 -4.1 0 -4 -4.2 05/16/2005 21:50:00 8.3 0.7 9.9 6.1 8.3 0.8 9.9 6.1 0.4 0 0.4 0.4 1 5 8 305 2 0 2 0 -4.2 0 -4 -4.5 05/16/2005 22:00:00 7.8 1 9.9 5.3 7.8 1 10.3 5.7 0.4 0 0.4 0.4 3 5 3 305 2 0 2 0 -4.3 0 -4.2 -4.5 05/16/2005 22:10:00 7.7 0.7 9.1 6.1 7.9 0.7 9.5 6.1 0.4 0 0.4 0.4 7 4 11 305 2 0 2 0 -4.4 0 -4 -4.5 05/16/2005 22:20:00 7.9 0.8 9.5 5.7 8 0.9 9.9 5.7 0.4 0 0.4 0.4 5 5 8 305 3 0 2 0 -4.4 0 -4 -4.5 05/16/2005 22:30:00 7.6 0.8 9.5 5.7 7.7 0.9 9.5 5.7 0.4 0 0.4 0.4 9 6 1 305 3 0 3 0 -4.3 0 -3.8 -4.5 05/16/2005 22:40:00 8 0.8 9.5 5.7 8.1 0.8 9.9 5.7 0.4 0 0.4 0.4 8 6 5 305 3 0 3 0 -4.4 0 -4 -4.7 05/16/2005 22:50:00 7.7 0.7 9.5 5.7 7.7 0.8 9.1 5.7 0.4 0 0.4 0.4 10 5 13 305 3 0 3 0 -4.7 0 -4.5 -4.7 05/16/2005 23:00:00 7.5 0.8 9.1 4.9 7.7 0.8 9.5 5.3 0.4 0 0.4 0.4 9 5 11 305 3 0 3 0 -4.9 0 -4.7 -5.1 05/16/2005 23:10:00 7.2 0.9 9.1 4.9 7.1 1 9.1 4.9 0.4 0 0.4 0.4 7 6 359 305 3 0 3 0 -5 0 -4.9 -5.1 05/16/2005 23:20:00 7.2 0.9 9.1 4.9 7.1 0.9 9.5 4.9 0.4 0 0.4 0.4 7 5 5 305 4 0 4 0 -5 0 -4.9 -5.1 05/16/2005 23:30:00 7 0.7 8.8 4.9 7 0.8 8.8 4.6 0.4 0 0.4 0.4 8 5 6 305 5 0 5 0 -5.1 0 -4.9 -5.3 05/16/2005 23:40:00 6.5 0.6 8 4.6 6.7 0.6 8 4.9 0.4 0 0.4 0.4 5 5 4 305 6 0 6 0 -5.2 0 -5.1 -5.3 05/16/2005 23:50:00 6.7 0.8 9.1 4.9 6.7 0.8 9.9 4.9 0.4 0 0.4 0.4 6 5 10 305 8 1 8 0 -5.2 0 -5.1 -5.3 05/17/2005 00:00:00 7.7 0.8 9.5 5.3 7.6 0.9 9.9 5.3 0.4 0 0.4 0.4 3 5 1 305 10 1 11 0 -5.2 0 -4.9 -5.3 05/17/2005 00:10:00 8 0.8 9.5 5.7 8 0.8 10.3 5.7 0.4 0 0.4 0.4 2 5 2 305 12 0 11 0 -5.1 0 -5.1 -5.3 05/17/2005 00:20:00 8 0.8 10.3 5.7 8 0.8 9.9 6.1 0.4 0 0.4 0.4 2 5 357 305 14 0 13 0 -5.1 0 -4.7 -5.1 05/17/2005 00:30:00 6 1 8.4 4.2 5.9 1 8.4 4.2 0.4 0 0.4 0.4 17 9 4 305 15 0 14 0 -5 0 -4.9 -5.1 05/17/2005 00:40:00 6.2 0.8 7.6 4.2 6.1 0.8 8 4.2 0.4 0 0.4 0.4 34 6 32 305 16 0 16 0 -5 0 -4.7 -5.1 05/17/2005 00:50:00 7 1.2 9.1 4.2 7 1.1 9.1 4.6 0.4 0 0.4 0.4 17 10 21 305 17 0 17 0 -4.9 0 -4.7 -5.1 05/17/2005 01:00:00 7.2 0.8 8.8 4.9 7.4 0.8 8.8 5.7 0.4 0 0.4 0.4 7 5 3 305 17 0 17 0 -5 0 -4.9 -5.1 05/17/2005 01:10:00 6.9 0.7 8.8 4.9 7 0.8 8.8 4.9 0.4 0 0.4 0.4 6 6 2 305 17 0 17 0 -5 0 -4.9 -5.1 05/17/2005 01:20:00 6.7 0.7 8 4.9 6.9 0.7 8.4 5.3 0.4 0 0.4 0.4 7 4 3 305 17 0 17 0 -5 0 -4.7 -5.1 05/17/2005 01:30:00 7.1 0.9 8.8 4.6 7.2 0.9 9.5 4.6 0.4 0 0.4 0.4 6 5 4 305 16 0 16 0 -5.2 0 -5.1 -5.3 05/17/2005 01:40:00 7 0.8 8.8 5.3 7.1 0.8 9.1 4.9 0.4 0 0.4 0.4 1 5 2 305 16 0 16 0 -5.4 0 -5.1 -5.6 05/17/2005 01:50:00 7.5 0.8 9.1 4.6 7.7 0.9 9.5 4.2 0.4 0 0.4 0.4 2 6 350 305 15 0 15 0 -5.6 0.1 -5.3 -5.8 05/17/2005 02:00:00 7 0.7 8.4 5.3 7.1 0.7 8.4 5.3 0.4 0 0.4 0.4 5 7 12 305 15 0 15 0 -5.9 0.1 -5.8 -6 05/17/2005 02:10:00 6.6 0.8 8.4 4.6 6.8 0.8 8.8 4.9 0.4 0 0.4 0.4 4 6 11 305 14 0 14 0 -6 0 -5.8 -6 05/17/2005 02:20:00 6.5 0.8 8.4 4.9 6.7 0.8 8.4 4.9 0.4 0 0.4 0.4 6 5 10 305 14 0 14 0 -6.2 0 -6 -6.4 05/17/2005 02:30:00 6.3 0.8 8 4.2 6.4 0.8 8 4.6 0.4 0 0.4 0.4 4 5 8 305 14 0 14 0 -6.2 0 -6.2 -6.4 05/17/2005 02:40:00 7.2 0.7 8.8 5.3 7.3 0.7 9.1 5.3 0.4 0 0.4 0.4 10 5 4 305 14 0 14 0 -6.3 0 -6.2 -6.4 05/17/2005 02:50:00 6.6 0.8 8.8 4.9 6.7 0.8 8.4 5.3 0.4 0 0.4 0.4 11 6 13 305 14 0 14 0 -6.3 0 -6.2 -6.4 05/17/2005 03:00:00 7 0.8 9.1 5.3 7.2 0.8 9.1 5.3 0.4 0 0.4 0.4 9 6 13 305 15 0 15 0 -6.3 0 -5.8 -6.4 05/17/2005 03:10:00 7 0.7 8.8 4.9 7.1 0.8 9.1 5.3 0.4 0 0.4 0.4 11 6 12 305 15 0 15 0 -6.3 0 -6 -6.4 05/17/2005 03:20:00 7.2 1.1 9.9 4.6 7.3 1.1 9.9 4.6 0.4 0 0.4 0.4 14 5 12 305 15 0 15 0 -6.2 0 -6 -6.2 05/17/2005 03:30:00 7.8 0.8 9.5 4.9 8 0.8 9.5 5.3 0.4 0 0.4 0.4 7 6 6 305 15 0 15 0 -6.1 0 -6 -6.2 05/17/2005 03:40:00 7.2 0.8 9.1 5.3 7.4 0.8 9.5 5.3 0.4 0 0.4 0.4 2 5 10 305 16 0 16 0 -6.1 0 -6 -6.2 05/17/2005 03:50:00 7.1 0.9 8.8 4.9 7.2 0.9 9.1 4.6 0.4 0 0.4 0.4 2 8 356 305 16 0 15 0 -6.1 0 -5.8 -6.2 05/17/2005 04:00:00 7.2 0.7 8.8 5.3 7.2 0.7 9.1 5.7 0.4 0 0.4 0.4 3 5 358 305 16 0 16 0 -6.1 0 -6 -6.2 05/17/2005 04:10:00 6.9 0.7 8.8 5.3 7 0.8 8.8 4.9 0.4 0 0.4 0.4 9 5 13 305 16 0 16 0 -6 0 -5.8 -6 05/17/2005 04:20:00 6.6 0.6 8.4 4.9 6.8 0.6 8.8 5.3 0.4 0 0.4 0.4 13 4 10 305 16 0 16 0 -6 0 -5.8 -6 05/17/2005 04:30:00 7 0.8 8.8 4.9 7 0.8 8.8 5.3 0.4 0 0.4 0.4 9 7 2 305 16 0 16 0 -5.9 0 -5.8 -6 05/17/2005 04:40:00 8.2 1 11.1 5.7 8.4 1.1 11.1 5.7 0.4 0 0.4 0.4 4 5 2 305 16 0 16 0 -6 0 -5.8 -6.2 05/17/2005 04:50:00 7.6 1 9.5 4.9 7.7 1 10.3 4.9 0.4 0 0.4 0.4 12 7 9 305 15 0 15 0 -6.2 0 -6 -6.2 05/17/2005 05:00:00 7.5 0.6 9.5 5.7 7.5 0.7 9.1 5.3 0.4 0 0.4 0.4 12 6 12 305 15 0 15 0 -6.2 0 -6 -6.4 05/17/2005 05:10:00 6.8 0.6 8 5.3 7 0.7 8.4 5.3 0.4 0 0.4 0.4 10 5 7 305 15 0 15 0 -6.4 0.1 -6.2 -6.7 05/17/2005 05:20:00 6.6 0.8 8.4 4.9 6.7 0.8 9.1 4.9 0.4 0 0.4 0.4 16 5 15 305 15 0 15 0 -6.5 0 -6.2 -6.7 05/17/2005 05:30:00 7.1 0.9 8.8 4.9 7.3 0.9 9.5 5.3 0.4 0 0.4 0.4 20 5 16 305 15 0 15 0 -6.5 0 -6.4 -6.7 05/17/2005 05:40:00 7.4 0.6 9.1 5.7 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 18 5 18 305 15 0 15 0 -6.6 0 -6.7 -6.9 05/17/2005 05:50:00 7.1 1 9.1 4.9 7.3 1 9.5 5.3 0.4 0 0.4 0.4 18 5 18 305 16 0 15 0 -6.6 0 -6.4 -6.7 05/17/2005 06:00:00 7.4 0.9 9.9 4.9 7.5 0.9 9.9 5.7 0.4 0 0.4 0.4 21 7 14 305 16 0 16 0 -6.5 0 -6.4 -6.7 05/17/2005 06:10:00 7.6 0.8 9.5 5.7 7.6 0.8 9.1 5.3 0.4 0 0.4 0.4 23 6 13 305 16 0 16 0 -6.5 0.1 -6.2 -6.7 05/17/2005 06:20:00 7.8 0.8 9.9 6.1 8 0.7 9.9 6.1 0.4 0 0.4 0.4 18 5 23 305 16 0 16 0 -6.2 0 -6 -6.4 05/17/2005 06:30:00 8.2 0.9 9.9 6.1 8.2 0.9 9.9 5.3 0.4 0 0.4 0.4 17 5 13 305 16 0 16 0 -6.2 0 -6 -6.2 05/17/2005 06:40:00 8.6 0.8 9.9 6.1 8.7 0.8 10.3 5.7 0.4 0 0.4 0.4 18 5 29 305 16 0 16 0 -6.2 0 -6 -6.2 05/17/2005 06:50:00 8.6 0.6 10.3 6.8 8.7 0.6 10.3 6.8 0.4 0 0.4 0.4 19 5 16 305 16 0 15 0 -6.2 0 -6 -6.2 05/17/2005 07:00:00 8.2 1 10.3 5.3 8.3 1 10.3 5.3 0.4 0 0.4 0.4 21 4 17 305 15 0 15 0 -6.2 0 -6 -6.4 05/17/2005 07:10:00 8.3 0.9 10.3 5.7 8.4 0.8 10.7 5.7 0.4 0 0.4 0.4 21 6 20 305 15 0 15 0 -6.1 0 -6 -6.2 05/17/2005 07:20:00 8.3 0.7 9.9 6.1 8.4 0.8 9.9 6.5 0.4 0 0.4 0.4 20 6 16 305 15 0 15 0 -6.2 0 -5.8 -6.2 05/17/2005 07:30:00 8.1 0.8 9.5 5.7 8.1 0.8 9.9 5.7 0.4 0 0.4 0.4 22 5 21 305 14 0 14 0 -6.1 0 -6 -6.2 05/17/2005 07:40:00 8.3 0.8 9.9 6.1 8.4 0.8 9.9 6.1 0.4 0 0.4 0.4 22 5 16 305 14 0 14 0 -6.1 0 -5.6 -6.2 05/17/2005 07:50:00 7.7 0.9 9.9 5.3 7.8 1 9.9 5.3 0.4 0 0.4 0.4 23 5 20 305 14 0 14 0 -6.1 0 -5.8 -6.2 05/17/2005 08:00:00 8.1 0.7 9.9 6.1 8.3 0.8 10.3 6.5 0.4 0 0.4 0.4 22 5 19 305 13 0 13 0 -6 0 -5.8 -6 05/17/2005 08:10:00 8 1 9.9 4.9 8.1 1 9.9 5.7 0.4 0 0.4 0.4 21 6 15 305 13 0 13 0 -5.9 0 -5.6 -6 05/17/2005 08:20:00 7.9 1 10.3 6.1 7.8 0.8 10.3 5.3 0.4 0 0.4 0.4 20 6 22 305 12 0 13 0 -5.6 0 -5.6 -5.8 05/17/2005 08:30:00 7.9 0.8 9.9 6.1 7.9 0.8 9.9 6.1 0.4 0 0.4 0.4 18 6 14 305 12 0 12 0 -5.7 0 -5.6 -5.8 05/17/2005 08:40:00 7.9 0.8 9.5 5.7 7.9 0.8 9.5 5.7 0.4 0 0.4 0.4 17 5 15 305 12 0 12 0 -5.7 0 -5.6 -5.8 05/17/2005 08:50:00 7.7 0.8 9.9 5.7 7.8 0.8 9.9 5.7 0.4 0 0.4 0.4 16 5 20 305 11 0 12 0 -5.7 0 -5.6 -5.8 05/17/2005 09:00:00 8 0.8 9.9 5.7 8.1 0.9 10.3 5.7 15 6 17 305 -5.6 0 -5.3 -5.8 05/17/2005 09:10:00 7.7 0.9 9.9 5.3 7.8 0.9 9.5 5.7 15 4 12 305 -5.5 0 -5.3 -5.6 05/17/2005 09:20:00 7.7 0.9 9.5 4.6 7.8 0.8 10.3 5.3 14 5 15 305 -5.5 0 -5.3 -5.8 05/17/2005 09:30:00 7.2 0.9 9.1 4.9 7.3 0.9 9.5 4.9 13 6 10 305 -5.5 0 -5.1 -6 05/17/2005 09:40:00 7.1 1 9.1 4.9 7.2 1 9.9 5.3 14 6 12 305 -5.3 0 -4.9 -5.8 05/17/2005 09:50:00 7 0.9 8.8 4.6 7 1 9.1 4.6 12 6 11 305 -5.3 0 -5.1 -5.6 05/17/2005 10:00:00 6.7 0.8 8.4 4.6 6.8 0.8 8.4 4.6 6 5 14 305 -5.1 0 -4.9 -5.3 05/17/2005 10:10:00 6.8 0.7 8 4.6 7 0.6 8.4 5.3 10 4 5 305 -5.1 0 -4.7 -5.3 05/17/2005 10:20:00 6.3 0.6 7.6 4.2 6.5 0.6 8 4.6 3 5 6 305 -5 0 -4.7 -5.1 05/17/2005 10:30:00 6.5 0.7 8.4 4.6 6.7 0.8 8.4 4.6 6 6 3 305 -4.9 0.1 -4.7 -5.1 05/17/2005 10:40:00 6.5 0.7 8.4 4.6 6.7 0.8 8 4.6 2 5 356 305 -4.7 0.1 -4.5 -4.9 05/17/2005 10:50:00 6.8 0.6 8.4 4.9 6.9 0.7 8.4 4.6 7 4 10 305 -4.8 0 -4.5 -4.9 05/17/2005 11:00:00 6.5 0.7 8 4.9 6.7 0.7 8.4 4.9 10 6 15 305 -4.6 0 -4 -4.7 05/17/2005 11:10:00 6.4 0.6 7.6 4.6 6.6 0.7 8 4.6 6 6 357 305 -4.6 0.1 -4.2 -4.9 05/17/2005 11:20:00 6.1 0.7 7.6 4.2 6.4 0.7 8 4.9 9 6 9 305 -4.5 0.1 -4 -4.7 05/17/2005 11:30:00 5.8 0.6 7.2 4.2 6.2 0.6 7.6 4.6 4 5 5 305 -4.4 0.1 -4 -4.7 05/17/2005 11:40:00 5.9 0.6 7.6 4.2 6.2 0.6 7.6 4.6 10 4 16 305 -4.4 0 -4 -4.5 05/17/2005 11:50:00 5.4 0.6 6.5 3.8 5.6 0.6 6.8 4.2 12 6 18 305 -4.2 0.1 -4 -4.5 05/17/2005 12:00:00 5.5 0.7 6.8 3.4 5.7 0.6 7.2 4.2 15 9 23 305 -4.2 0.1 -3.8 -4.5 05/17/2005 12:10:00 5.5 0.5 6.8 4.2 5.6 0.5 6.8 3.8 19 6 20 305 -4.2 0.1 -3.8 -4.5 05/17/2005 12:20:00 4.7 0.6 6.1 3 5 0.6 6.5 3.4 16 7 14 305 -4 0 -3.8 -4.2 05/17/2005 12:30:00 5.2 0.5 6.1 3.8 5.4 0.5 7.2 4.2 23 6 23 305 -3.9 0 -3.6 -4 05/17/2005 12:40:00 5.1 0.6 6.5 3 5.3 0.6 6.5 3.4 19 7 24 305 -3.8 0 -3.6 -4 05/17/2005 12:50:00 4.5 0.6 6.1 2.6 4.7 0.6 6.5 3.4 10 8 18 305 -3.6 0.1 -3.3 -4 05/17/2005 13:00:00 4.5 0.5 6.1 3.4 4.8 0.5 6.5 3 14 7 9 305 -3.8 0 -3.6 -4 05/17/2005 13:10:00 4.3 0.5 5.7 3 4.6 0.6 6.1 3 21 8 30 305 -3.8 0 -3.3 -3.8 05/17/2005 13:20:00 4.3 0.5 5.7 2.6 4.6 0.5 5.7 3.4 15 7 18 305 -3.7 0.1 -3.3 -3.8 05/17/2005 13:30:00 3.7 0.5 4.9 3 4 0.5 5.7 2.6 13 10 19 305 -3.5 0.1 -3.1 -3.8 05/17/2005 13:40:00 4 0.6 6.1 2.6 4.2 0.6 6.5 3 15 10 14 305 -3.6 0 -3.3 -3.8 05/17/2005 13:50:00 3.7 0.5 4.9 2.3 3.8 0.5 5.3 2.6 17 10 8 305 -3.7 0 -3.3 -4 05/17/2005 14:00:00 3.5 0.5 4.6 2.3 3.7 0.4 4.9 2.6 10 9 24 305 -3.3 0 -3.1 -3.6 05/17/2005 14:10:00 3.2 0.5 4.6 1.9 3.4 0.6 4.9 2.3 16 9 11 305 -3.6 0.1 -3.3 -4 05/17/2005 14:20:00 3.2 0.5 4.2 1.9 3.4 0.5 4.6 2.3 11 9 12 305 -3.7 0.1 -3.3 -3.8 05/17/2005 14:30:00 3.3 0.4 4.6 2.3 3.5 0.4 4.9 2.6 17 7 15 305 -3.5 0.2 -2.9 -3.8 05/17/2005 14:40:00 2.6 0.4 4.2 1.5 2.9 0.4 3.8 2.3 15 8 22 305 -3.3 0 -2.9 -3.6 05/17/2005 14:50:00 2.1 0.6 3.8 0.4 2.4 0.5 3.8 0.7 28 17 40 305 -3.3 0 -3.1 -3.3 05/17/2005 15:00:00 2.4 0.6 3.4 0.4 2.6 0.6 3.8 1.1 18 17 5 305 -3.2 0 -2.7 -3.3 05/17/2005 15:10:00 2.2 0.6 3.8 0.4 2.6 0.5 4.2 1.1 17 10 24 305 -3.2 0.1 -2.7 -3.3 05/17/2005 15:20:00 1.8 0.6 3 0.4 2.1 0.5 3.4 0.7 17 15 25 305 -3 0.1 -2.4 -3.3 05/17/2005 15:30:00 1.9 0.6 3.4 0.4 2.4 0.5 3.4 1.1 351 15 349 305 -2.8 0.1 -2.2 -3.1 05/17/2005 15:40:00 1.6 0.7 3 0.4 2 0.6 3.8 0.7 20 12 16 305 -2.8 0 -2.4 -3.1 05/17/2005 15:50:00 1.8 0.4 2.6 0.4 2.2 0.3 3 1.1 6 11 11 305 -3 0.1 -2.4 -3.3 05/17/2005 16:00:00 1.8 0.5 3 0.4 2.2 0.4 3.4 1.5 349 17 348 305 -2.9 0 -2.4 -3.1 05/17/2005 16:10:00 2.1 0.5 3.4 1.1 2.4 0.4 3.4 1.1 5 10 17 305 -2.9 0.1 -2.4 -3.1 05/17/2005 16:20:00 2.4 0.5 3.8 1.1 2.6 0.4 3.4 1.5 9 12 24 305 -3 0.1 -2.4 -3.3 05/17/2005 16:30:00 2.5 0.6 3.8 1.1 2.7 0.5 4.2 1.5 8 11 13 305 -3 0.1 -2.4 -3.1 05/17/2005 16:40:00 1.3 0.8 3 0.4 1.8 0.6 3 0.4 345 14 13 305 -2.6 0.2 -1.8 -2.9 05/17/2005 16:50:00 0.9 0.7 3 0.4 1.3 0.7 3 0.4 193 64 209 305 -2 0.1 -1.5 -2.4 05/17/2005 17:00:00 1.9 0.6 3.4 0.4 2.3 0.5 3.4 1.1 206 19 200 305 -2.6 0.1 -2 -2.9 05/17/2005 17:10:00 1.7 0.6 3.4 0.4 1.9 0.5 3 0.7 225 20 218 305 -2.8 0 -2.2 -3.1 05/17/2005 17:20:00 1.8 0.7 3.4 0.4 2.1 0.6 3.4 0.7 239 17 226 305 -3 0.1 -2.4 -3.3 05/17/2005 17:30:00 1.7 0.5 3 0.4 2 0.5 3 0.4 212 21 222 305 -2.7 0.2 -2 -2.9 05/17/2005 17:40:00 0.6 0.4 1.9 0.4 1.1 0.5 2.3 0.4 212 33 184 305 -2.4 0.2 -1.8 -2.7 05/17/2005 17:50:00 2 0.8 3.4 0.4 2.3 0.7 3.4 0.7 226 14 203 305 -2.8 0.3 -2 -3.3 05/17/2005 18:00:00 1.4 0.7 3 0.4 1.7 0.6 3.4 0.4 230 15 208 305 -2.8 0.2 -2.2 -3.1 05/17/2005 18:10:00 1.3 0.7 3 0.4 1.8 0.6 3 0.4 201 20 215 305 -2.7 0.1 -2.2 -2.7 05/17/2005 18:20:00 1.9 0.6 3.4 0.4 2.2 0.5 3.4 1.1 207 11 210 305 -2.8 0.1 -2.2 -3.1 05/17/2005 18:30:00 1.4 0.6 3 0.4 1.9 0.5 3.4 0.7 206 10 200 305 -2.8 0 -2.4 -3.1 05/17/2005 18:40:00 0.8 0.6 2.6 0.4 1.1 0.7 2.6 0.4 227 27 226 305 -2.7 0.1 -2 -2.9 05/17/2005 18:50:00 0.6 0.5 2.3 0.4 0.8 0.5 2.3 0.4 271 30 240 305 -2.3 0.2 -1.8 -2.7 05/17/2005 19:00:00 1.3 0.9 3.4 0.4 1.7 0.6 3.4 0.4 228 18 249 305 -2.6 0.2 -2 -2.7 05/17/2005 19:10:00 1.7 0.6 3 0.4 2 0.5 3 0.7 233 14 238 305 -3.1 0.2 -2.2 -3.3 05/17/2005 19:20:00 0.9 0.6 2.6 0.4 1.1 0.5 2.3 0.4 259 69 263 305 -2.8 0.2 -2.2 -3.1 05/17/2005 19:30:00 0.5 0.3 1.5 0.4 0.8 0.4 2.3 0.4 284 12 288 305 -2.8 0 -2.2 -2.9 05/17/2005 19:40:00 1.8 0.8 3.8 0.4 1.8 0.6 3.4 0.4 270 10 279 305 -3 0.2 -2.4 -3.3 05/17/2005 19:50:00 0.6 0.4 1.9 0.4 1 0.5 1.9 0.4 226 21 245 305 -3.1 0.1 -2.7 -3.3 05/17/2005 20:00:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 337 38 305 305 -2.7 0.1 -2 -3.1 05/17/2005 20:10:00 0.4 0.2 1.9 0.4 0.7 0.4 2.3 0.4 336 23 343 305 -2.6 0 -2.2 -2.7 05/17/2005 20:20:00 0.9 0.6 2.6 0.4 1.4 0.6 3 0.4 358 14 329 305 -2.8 0.1 -2.2 -3.1 05/17/2005 20:30:00 0.5 0.4 1.9 0.4 1 0.5 2.3 0.4 340 45 14 305 -3 0 -2.4 -3.1 05/17/2005 20:40:00 0.7 0.5 2.6 0.4 1.3 0.5 2.6 0.4 17 20 24 305 -3.1 0 -2.7 -3.1 05/17/2005 20:50:00 0.9 0.6 2.3 0.4 1.5 0.6 2.6 0.4 34 11 31 305 -3.1 0.1 -2.7 -3.3 05/17/2005 21:00:00 1.1 0.6 2.6 0.4 1.5 0.5 2.6 0.4 63 16 47 305 -3.2 0.1 -2.7 -3.3 05/17/2005 21:10:00 0.5 0.4 2.3 0.4 1 0.5 2.3 0.4 356 24 13 305 -3.1 0 -2.4 -3.1 05/17/2005 21:20:00 0.6 0.4 2.3 0.4 1.2 0.5 2.6 0.4 327 20 330 305 -3.1 0 -2.7 -3.3 05/17/2005 21:30:00 0.8 0.4 2.3 0.4 1.5 0.4 2.6 0.7 320 13 329 305 -3.1 0 -2.7 -3.1 05/17/2005 21:40:00 1 0.5 2.3 0.4 1.6 0.4 2.3 0.7 295 13 302 305 -3.1 0 -2.7 -3.1 05/17/2005 21:50:00 0.7 0.4 1.9 0.4 1.2 0.4 2.3 0.4 306 26 332 305 -3.1 0 -2.9 -3.1 05/17/2005 22:00:00 1.6 0.5 2.6 0.4 2 0.4 3 1.1 324 11 307 305 -3.2 0 -3.1 -3.3 05/17/2005 22:10:00 2.1 0.4 3 1.1 2.5 0.4 3.4 1.5 326 7 333 305 -3.2 0 -3.1 -3.3 05/17/2005 22:20:00 1.3 0.5 2.6 0.4 1.8 0.3 2.6 1.1 301 8 305 305 -3.2 0 -3.1 -3.3 05/17/2005 22:30:00 1.1 0.6 2.6 0.4 1.6 0.4 2.6 0.7 303 7 310 305 -3.3 0 -3.1 -3.3 05/17/2005 22:40:00 1.2 0.8 3 0.4 1.4 0.9 3.4 0.4 292 9 290 305 -3.3 0 -3.3 -3.6 05/17/2005 22:50:00 2 0.5 3.4 0.4 2.3 0.4 3.4 0.7 311 9 297 305 -3.3 0 -3.3 -3.6 05/17/2005 23:00:00 2.4 0.5 3.8 0.4 2.7 0.5 3.8 1.1 302 12 308 305 -3.3 0 -3.3 -3.6 05/17/2005 23:10:00 1.2 0.8 3 0.4 1.6 0.8 3.4 0.4 325 18 306 305 -3.4 0 -3.3 -3.6 05/17/2005 23:20:00 1 0.6 2.6 0.4 1.6 0.5 2.6 0.4 350 22 19 305 -3.5 0 -3.3 -3.6 05/17/2005 23:30:00 1.9 0.7 3 0.4 2.1 0.8 3.8 0.7 297 17 285 305 -3.5 0 -3.3 -3.6 05/17/2005 23:40:00 0.4 0.2 1.9 0.4 0.7 0.4 1.9 0.4 100 122 297 305 -3.5 0 -3.3 -3.6 05/17/2005 23:50:00 1.7 1 4.2 0.4 2.1 0.7 4.2 1.1 314 9 303 305 -3.4 0 -3.3 -3.6 05/18/2005 00:00:00 0.4 0 0.7 0.4 0.7 0.4 1.9 0.4 309 19 326 305 -3.4 0 -2.9 -3.6 05/18/2005 00:10:00 0.8 0.6 2.6 0.4 1.4 0.5 2.6 0.7 333 32 287 305 -3.3 0 -3.3 -3.6 05/18/2005 00:20:00 0.4 0.1 1.5 0.4 0.6 0.5 2.3 0.4 333 26 314 305 -3.4 0 -3.3 -3.6 05/18/2005 00:30:00 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 345 6 344 305 -3.5 0 -3.3 -3.6 05/18/2005 00:40:00 0.4 0.2 1.5 0.4 1 0.4 1.9 0.4 347 5 359 305 -3.4 0 -3.3 -3.6 05/18/2005 00:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 291 32 305 305 -3.4 0 -3.3 -3.6 05/18/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 253 0 305 305 -3.4 0 -3.3 -3.6 05/18/2005 01:10:00 0.4 0.1 1.1 0.4 0.9 0.4 1.9 0.4 349 19 11 305 -3.4 0 -3.1 -3.6 05/18/2005 01:20:00 0.4 0 0.4 0.4 0.7 0.5 1.9 0.4 345 22 305 305 -3.3 0 -3.3 -3.6 05/18/2005 01:30:00 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 278 2 277 305 -3.3 0 -3.3 -3.3 05/18/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 277 0 305 305 -3.3 0 -3.3 -3.3 05/18/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 260 9 305 305 -3.3 0 -3.1 -3.3 05/18/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 254 0 305 305 -3.3 0 -3.3 -3.3 05/18/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 255 0 305 305 -3.3 0 -3.1 -3.3 05/18/2005 02:20:00 1.1 0.6 2.3 0.4 1.6 0.7 2.6 0.4 13 49 36 305 -3.3 0 -3.1 -3.3 05/18/2005 02:30:00 0.8 0.5 1.9 0.4 1.6 0.3 2.3 0.7 69 13 72 305 -3.4 0 -3.3 -3.6 05/18/2005 02:40:00 0.9 0.3 1.5 0.4 1.6 0.2 2.3 1.1 102 7 101 305 -3.3 0 -3.3 -3.6 05/18/2005 02:50:00 0.4 0.2 1.5 0.4 1.3 0.4 2.3 0.4 119 12 108 305 -3.5 0 -3.3 -3.6 05/18/2005 03:00:00 0.4 0.2 1.1 0.4 1.3 0.3 1.9 0.7 136 6 130 305 -3.5 0 -3.3 -3.6 05/18/2005 03:10:00 0.4 0.2 1.5 0.4 1.2 0.4 2.3 0.7 135 16 130 305 -3.5 0 -3.3 -3.6 05/18/2005 03:20:00 0.4 0.2 1.1 0.4 1 0.5 2.3 0.4 170 21 144 305 -3.4 0 -3.3 -3.6 05/18/2005 03:30:00 0.4 0.2 1.1 0.4 1.2 0.2 1.9 0.7 192 12 191 305 -3.3 0 -3.1 -3.3 05/18/2005 03:40:00 0.4 0.1 1.5 0.4 1 0.3 1.5 0.4 201 8 208 305 -3.3 0 -3.1 -3.3 05/18/2005 03:50:00 0.5 0.3 1.5 0.4 1.3 0.3 1.9 0.4 197 13 201 305 -3.2 0 -3.1 -3.3 05/18/2005 04:00:00 0.4 0.1 1.1 0.4 1.1 0.3 1.9 0.4 202 5 201 305 -3.1 0 -3.1 -3.3 05/18/2005 04:10:00 1.2 1 3.8 0.4 1.5 0.7 3.4 0.4 225 22 234 305 -3.1 0 -3.1 -3.1 05/18/2005 04:20:00 3.8 0.5 4.9 2.3 3.6 0.5 4.6 1.9 235 7 238 305 -2.8 0 -2.7 -3.1 05/18/2005 04:30:00 4.4 0.9 6.1 2.3 3.7 0.7 5.3 1.9 255 7 259 305 -2.8 0 -2.7 -2.9 05/18/2005 04:40:00 3.9 0.4 4.9 2.6 3.4 0.5 4.9 1.9 256 6 255 305 -2.8 0 -2.7 -2.9 05/18/2005 04:50:00 3.7 0.5 4.9 2.3 3.3 0.5 4.6 1.9 253 7 258 305 -2.8 0 -2.7 -2.9 05/18/2005 05:00:00 4.1 0.5 5.3 3 3.6 0.6 4.9 2.3 254 5 254 305 -2.8 0 -2.7 -2.9 05/18/2005 05:10:00 3.9 0.6 5.3 1.9 3.4 0.7 4.9 1.5 257 7 263 305 -2.8 0 -2.7 -2.7 05/18/2005 05:20:00 3.5 0.5 4.9 1.9 2.9 0.5 4.2 1.5 261 7 262 305 -2.7 0 -2.7 -2.7 05/18/2005 05:30:00 3.3 0.4 4.6 1.9 2.9 0.5 4.2 1.5 255 7 254 305 -2.7 0 -2.4 -2.7 05/18/2005 05:40:00 3.7 1 5.3 1.9 3.3 1 5.3 1.5 277 18 292 305 -2.6 0 -2.4 -2.7 05/18/2005 05:50:00 5.2 0.7 6.8 3.8 4.9 0.7 6.8 3 293 13 291 305 -2.6 0 -2.4 -2.7 05/18/2005 06:00:00 4.5 0.6 6.1 3.4 4.5 0.6 6.1 3 310 9 310 305 -2.6 0 -2.4 -2.7 05/18/2005 06:10:00 3.6 0.9 5.7 1.9 3.8 0.8 6.1 2.3 329 10 322 305 -2.8 0 -2.7 -2.9 05/18/2005 06:20:00 2.3 0.3 3.4 1.5 2.7 0.3 3.8 1.9 351 10 348 305 -3 0 -2.7 -3.1 05/18/2005 06:30:00 1.2 0.6 2.6 0.4 1.8 0.5 3 0.7 2 9 1 305 -3 0 -2.9 -3.1 05/18/2005 06:40:00 0.9 0.5 2.3 0.4 1.2 0.4 2.6 0.4 357 17 336 305 -3 0 -2.9 -3.1 05/18/2005 06:50:00 1.4 0.5 2.6 0.4 1.9 0.4 3 0.7 354 19 337 305 -3 0 -2.7 -3.1 05/18/2005 07:00:00 0.6 0.5 3.8 0.4 1 0.5 2.3 0.4 349 38 266 305 -3 0 -2.7 -3.1 05/18/2005 07:10:00 3.4 1.9 7.2 0.4 3.4 1.5 6.8 0.7 322 33 288 305 -3 0 -2.7 -3.1 05/18/2005 07:20:00 5.6 0.6 6.8 3.8 5.4 0.6 6.8 3.8 298 9 291 305 -2.7 0 -2.4 -2.9 05/18/2005 07:30:00 5.4 0.6 6.8 3.8 5.2 0.6 6.5 3.8 296 7 298 305 -2.6 0 -2.2 -2.7 05/18/2005 07:40:00 5.7 0.7 7.2 3.8 5.5 0.7 6.8 3.8 297 7 290 305 -2.6 0 -2.4 -2.7 05/18/2005 07:50:00 6.1 0.7 7.6 4.6 5.8 0.7 7.2 4.2 296 5 297 305 -2.6 0 -2.4 -2.7 05/18/2005 08:00:00 5.2 0.8 7.2 3.4 5.1 0.7 6.8 3.4 298 8 291 305 -2.5 0 -2.4 -2.7 05/18/2005 08:10:00 4.5 0.5 6.5 3.4 4.5 0.5 6.1 3.4 304 9 303 305 -2.4 0 -2.2 -2.4 05/18/2005 08:20:00 4.7 0.7 6.5 3 4.7 0.7 6.5 3 303 11 291 305 -2.3 0 -2.2 -2.4 05/18/2005 08:30:00 5.1 0.6 7.2 3.8 5 0.5 6.8 3.8 304 12 303 305 -2.3 0 -2 -2.4 05/18/2005 08:40:00 5.4 0.6 7.2 3.8 5.3 0.6 7.2 3.8 304 15 303 305 -2.2 0 -2 -2.4 05/18/2005 08:50:00 5.3 0.5 6.5 3.8 5.3 0.5 6.8 3.8 306 12 303 305 -2.3 0 -2.2 -2.4 05/18/2005 09:00:00 4.7 0.5 5.7 3.4 4.7 0.5 5.7 3.4 307 13 292 305 -2.3 0 -2.2 -2.4 05/18/2005 09:10:00 4.9 0.6 6.1 3.4 4.9 0.5 6.1 3.4 308 12 305 305 -2.2 0 -2 -2.4 05/18/2005 09:20:00 5 0.6 6.5 3.4 5.1 0.6 6.5 3.4 306 9 303 305 -2 0 -1.8 -2.2 05/18/2005 09:30:00 5.1 0.5 6.1 3.8 5.2 0.5 6.1 4.2 310 8 305 305 -2 0 -1.8 -2.2 05/18/2005 09:40:00 4.9 0.7 6.5 3 5 0.7 6.5 3 308 13 305 305 -1.9 0 -1.8 -2 05/18/2005 09:50:00 4.9 0.6 6.5 3.4 4.9 0.6 6.5 3.4 306 10 305 305 -1.8 0 -1.3 -2 05/18/2005 10:00:00 4.9 0.6 6.5 3.4 5 0.6 6.5 3.4 307 7 306 305 -1.7 0 -1.5 -1.8 05/18/2005 10:10:00 5.2 0.6 6.5 3.8 5.2 0.6 6.5 3.4 303 15 306 305 -1.7 0.1 -1.1 -2 05/18/2005 10:20:00 5.9 0.6 7.2 4.2 5.7 0.6 7.2 4.2 299 6 293 305 -1.8 0 -1.3 -2 05/18/2005 10:30:00 5.6 0.6 6.8 3.8 5.6 0.5 6.8 3.8 302 11 309 305 -1.8 0.1 -1.3 -2 05/18/2005 10:40:00 5.4 0.5 6.5 4.2 5.4 0.5 6.8 4.2 302 12 299 305 -1.4 0.1 -1.1 -1.8 05/18/2005 10:50:00 5.9 0.5 7.6 4.6 5.9 0.5 7.2 4.6 301 8 311 305 -1.6 0 -1.3 -1.8 05/18/2005 11:00:00 5.8 0.5 7.2 4.2 5.8 0.5 7.2 4.2 295 7 283 305 -1.6 0.1 -1.3 -2 05/18/2005 11:10:00 5.5 0.5 7.6 4.2 5.5 0.5 7.2 4.2 301 9 308 305 -1.4 0 -1.1 -1.8 05/18/2005 11:20:00 5.7 0.5 6.8 4.2 5.7 0.6 6.8 4.2 301 9 298 305 -1.6 0 -1.3 -1.8 05/18/2005 11:30:00 5.6 0.6 7.2 4.2 5.5 0.6 6.8 4.2 302 17 302 305 -1.6 0 -1.5 -1.8 05/18/2005 11:40:00 5.7 0.6 7.2 4.2 5.7 0.6 7.2 4.2 300 7 288 305 -1.7 0.1 -1.1 -2 05/18/2005 11:50:00 5.8 0.5 7.2 4.6 5.7 0.5 6.8 4.2 296 9 311 305 -1.6 0 -1.1 -1.8 05/18/2005 12:00:00 5.9 0.5 6.8 4.6 5.8 0.4 6.8 4.6 294 8 303 305 -1.7 0 -1.1 -2 05/18/2005 12:10:00 5.8 0.5 7.2 4.6 5.6 0.6 7.2 3.8 294 9 292 305 -1.6 0.2 -1.1 -2 05/18/2005 12:20:00 5.8 0.6 7.6 4.2 5.7 0.6 7.6 4.2 296 8 299 305 -1.4 0.1 -0.6 -1.8 05/18/2005 12:30:00 5.6 0.6 7.2 4.2 5.5 0.6 8 3.8 297 8 299 305 -1.4 0.2 -0.6 -1.8 05/18/2005 12:40:00 5.2 0.6 6.8 3.4 5 0.7 6.8 3.4 292 13 303 305 -1.4 0.1 -0.8 -1.5 05/18/2005 12:50:00 4.7 0.7 6.5 3 4.7 0.6 6.1 3 296 9 295 305 -1.2 0.1 -0.6 -1.3 05/18/2005 13:00:00 4.5 0.7 6.5 2.6 4.4 0.6 6.1 2.6 299 13 300 305 -0.8 0.2 0.1 -1.1 05/18/2005 13:10:00 4.1 0.5 6.1 2.6 4.2 0.5 5.7 2.6 304 10 305 305 -1 0.1 -0.4 -1.1 05/18/2005 13:20:00 4.1 0.5 5.3 2.6 4.3 0.5 5.3 3 316 12 314 305 -1.1 0.2 -0.4 -1.3 05/18/2005 13:30:00 3.9 0.6 5.7 2.3 4.1 0.6 6.1 2.6 320 10 311 305 -1 0.1 -0.4 -1.3 05/18/2005 13:40:00 3.6 0.5 4.9 1.9 3.8 0.5 4.9 1.9 318 11 350 305 -0.6 0.1 -0.1 -1.1 05/18/2005 13:50:00 2.8 0.5 4.2 1.9 3.1 0.4 4.2 1.9 340 7 330 305 -1.1 0 -0.6 -1.3 05/18/2005 14:00:00 2.9 0.5 4.6 1.5 3.2 0.5 4.6 2.3 350 8 357 305 -1 0.1 -0.6 -1.3 05/18/2005 14:10:00 3.1 0.4 4.2 2.3 3.3 0.4 4.2 2.3 357 8 351 305 -1.2 0.1 -0.6 -1.5 05/18/2005 14:20:00 3.1 0.5 4.2 1.9 3.4 0.5 4.6 2.3 352 10 344 305 -1.1 0.1 -0.4 -1.5 05/18/2005 14:30:00 3.6 0.6 4.9 1.9 3.7 0.6 4.9 1.9 349 8 12 305 -1.1 0 -0.6 -1.3 05/18/2005 14:40:00 3.2 0.5 4.2 1.9 3.5 0.5 4.6 2.3 348 10 4 305 -1.1 0.1 -0.4 -1.3 05/18/2005 14:50:00 2.9 0.5 4.2 1.5 3.2 0.5 4.6 1.9 349 9 354 305 -1.2 0.2 -0.4 -1.5 05/18/2005 15:00:00 2.6 0.6 4.2 0.7 2.9 0.6 4.2 1.1 334 17 333 305 -0.8 0.3 0.1 -1.3 05/18/2005 15:10:00 3.4 0.8 5.7 0.4 3.6 0.7 5.3 1.5 320 11 305 305 -0.4 0.2 0.3 -0.8 05/18/2005 15:20:00 3.4 0.5 5.3 2.3 3.5 0.5 5.3 2.6 312 12 290 305 -0.4 0.2 0.3 -0.6 05/18/2005 15:30:00 3.4 0.5 4.6 1.9 3.6 0.5 4.9 1.9 314 10 311 305 -0.4 0.1 0.1 -0.6 05/18/2005 15:40:00 3.3 0.6 4.6 1.9 3.4 0.6 4.9 1.9 311 9 314 305 -0.3 0.1 0.3 -0.6 05/18/2005 15:50:00 3.7 0.6 5.3 2.3 3.7 0.6 4.9 1.9 298 13 308 305 -0.1 0.2 0.6 -0.4 05/18/2005 16:00:00 3.9 0.8 6.1 2.3 3.9 0.8 6.1 2.3 296 10 297 305 -0.2 0.2 0.6 -0.6 05/18/2005 16:10:00 5.1 0.7 6.8 3.4 5.1 0.7 7.2 3.4 301 10 295 305 0.2 0.2 0.6 -0.4 05/18/2005 16:20:00 4.5 0.5 6.5 3.4 4.7 0.5 6.5 3.4 307 9 303 305 0.2 0.2 0.8 -0.1 05/18/2005 16:30:00 5.1 0.5 6.5 4.2 5.2 0.5 6.5 3.8 302 7 301 305 0.2 0.2 0.8 -0.1 05/18/2005 16:40:00 4.7 0.5 6.5 3.4 4.8 0.5 6.5 3.4 307 7 293 305 0 0.1 0.6 -0.1 05/18/2005 16:50:00 5 0.5 6.1 3.8 5.1 0.5 6.5 3.8 307 10 303 305 0.3 0.2 0.8 0.1 05/18/2005 17:00:00 5.2 0.5 6.5 3.8 5.2 0.5 6.1 4.2 310 9 312 305 0.3 0.2 1 0.1 05/18/2005 17:10:00 4.9 0.6 6.5 3.8 5 0.5 6.1 3.8 306 8 296 305 0.4 0.2 1 0.1 05/18/2005 17:20:00 5.9 0.5 7.2 4.2 5.9 0.5 7.2 4.6 302 6 302 305 0.7 0.1 1.3 0.3 05/18/2005 17:30:00 6 0.6 7.6 4.6 6 0.6 7.6 4.6 302 7 288 305 0.6 0.2 1.3 0.3 05/18/2005 17:40:00 6.5 0.6 7.6 4.9 6.4 0.6 7.6 4.6 299 9 295 305 0.7 0.1 1.5 0.6 05/18/2005 17:50:00 6.9 0.6 8 4.6 6.8 0.6 8.4 5.3 296 6 296 305 0.6 0.1 1.3 0.3 05/18/2005 18:00:00 6.7 0.6 8 5.3 6.6 0.6 8 4.9 295 8 293 305 0.7 0.2 1.3 0.6 05/18/2005 18:10:00 6.7 0.5 7.6 4.9 6.7 0.6 8 5.3 298 12 293 305 0.5 0 1 0.3 05/18/2005 18:20:00 7.1 0.6 8.8 5.7 7 0.6 8.4 5.3 298 8 290 305 0.6 0.1 1 0.6 05/18/2005 18:30:00 6.9 0.6 8.8 5.3 6.9 0.7 9.1 5.3 297 7 290 305 0.6 0.1 1 0.3 05/18/2005 18:40:00 7.3 0.8 9.1 4.9 7.1 0.7 8.8 5.3 296 6 293 305 0.6 0 1 0.3 05/18/2005 18:50:00 7.4 0.6 8.8 4.9 7.2 0.6 8.4 5.3 296 7 293 305 0.4 0.1 1 0.1 05/18/2005 19:00:00 7.4 0.7 8.8 5.3 7.3 0.8 8.8 5.3 295 6 294 305 0.3 0 0.8 0.1 05/18/2005 19:10:00 7.2 0.7 8.8 5.3 7.1 0.6 8.8 5.3 298 6 297 305 0 0 0.6 -0.1 05/18/2005 19:20:00 7.4 0.6 9.1 5.7 7.3 0.7 8.8 5.7 296 7 301 305 -0.1 0.1 0.6 -0.4 05/18/2005 19:30:00 7.1 0.6 8.8 5.3 6.9 0.7 8.8 5.3 294 7 287 305 -0.3 0.1 0.3 -0.6 05/18/2005 19:40:00 7.1 0.7 8.4 5.3 6.9 0.7 8.4 4.6 296 7 301 305 -0.4 0.2 0.1 -0.6 05/18/2005 19:50:00 7 0.7 8.8 4.9 6.9 0.7 8.8 4.6 296 13 300 305 -0.7 0 0.1 -0.8 05/18/2005 20:00:00 6.6 0.8 8.4 4.6 6.5 0.9 8.4 3.8 293 7 293 305 -0.7 0 -0.1 -1.1 05/18/2005 20:10:00 6.9 0.9 9.1 4.2 6.7 1 8.8 4.6 290 7 296 305 -1.1 0 -0.6 -1.1 05/18/2005 20:20:00 6.8 0.7 8.4 4.9 6.5 0.8 8.4 4.6 288 6 291 305 -1.1 0 -0.8 -1.3 05/18/2005 20:30:00 6.8 0.7 8.4 4.6 6.4 0.8 8 4.6 286 7 282 305 -1.2 0.2 -0.6 -1.5 05/18/2005 20:40:00 6.6 0.9 8.4 4.2 5.8 1 7.6 3.4 279 7 276 305 -1.6 0 -1.1 -1.8 05/18/2005 20:50:00 6.5 0.8 8.4 4.2 5.4 0.9 7.2 3 275 8 270 305 -1.6 0 -1.1 -1.8 05/18/2005 21:00:00 6.2 0.9 8 3.4 5.4 0.9 7.6 3 278 7 275 305 -1.6 0 -1.3 -1.8 05/18/2005 21:10:00 6.3 1.1 8.4 3.4 5.3 1 7.2 2.3 272 8 270 305 -1.7 0 -1.3 -1.8 05/18/2005 21:20:00 6.7 1 8.4 3.8 5.8 1 8 3 278 6 278 305 -1.6 0.1 -1.1 -2 05/18/2005 21:30:00 6.3 1.1 8.8 2.6 5.3 1 7.6 2.3 275 8 275 305 -1.5 0.1 -1.1 -1.8 05/18/2005 21:40:00 6.3 0.8 7.6 3.8 5.4 0.8 7.2 3.4 273 7 273 305 -1.4 0 -1.1 -1.5 05/18/2005 21:50:00 5.2 0.8 6.8 3 4.3 0.7 5.7 2.6 271 9 271 305 -1.5 0.1 -1.1 -1.8 05/18/2005 22:00:00 6.4 0.7 8 4.6 5 0.7 7.2 3.4 269 7 268 305 -1.8 0 -1.3 -2 05/18/2005 22:10:00 5.6 0.9 7.6 3 4.6 0.9 6.8 2.3 271 8 259 305 -1.9 0 -1.5 -2 05/18/2005 22:20:00 5.9 0.9 8 3 4.8 0.8 6.5 2.6 265 8 262 305 -2 0.1 -1.5 -2 05/18/2005 22:30:00 5.1 0.8 6.8 2.6 4.1 0.8 6.1 2.3 271 9 282 305 -2.1 0.1 -1.8 -2.2 05/18/2005 22:40:00 5.6 0.9 7.2 3 4.6 0.8 6.5 2.6 270 8 269 305 -2.2 0 -1.8 -2.4 05/18/2005 22:50:00 5.5 0.7 7.2 3.4 4.7 0.8 6.8 3 264 10 266 305 -2.2 0 -1.8 -2.4 05/18/2005 23:00:00 5.9 0.8 7.2 3 5.2 0.8 7.2 3 255 6 262 305 -2.3 0 -2.2 -2.4 05/18/2005 23:10:00 5.2 1 7.6 2.6 4.3 0.8 6.5 2.6 263 7 265 305 -2.4 0 -2.4 -2.4 05/18/2005 23:20:00 5.1 0.7 6.8 3.4 4.1 0.7 6.1 2.3 265 8 268 305 -2.4 0 -2.2 -2.4 05/18/2005 23:30:00 6.1 0.8 8 3.4 5.1 1 7.6 2.3 260 6 251 305 -2.4 0 -2.4 -2.7 05/18/2005 23:40:00 6.2 0.6 7.6 4.2 5.3 0.8 7.6 3 260 7 269 305 -2.6 0 -2.4 -2.7 05/18/2005 23:50:00 5.2 0.7 6.8 3 4.3 0.8 7.2 2.6 263 9 256 305 -2.7 0 -2.4 -2.7 05/19/2005 00:00:00 5.4 0.8 7.2 3 4.9 0.8 6.8 3 255 9 261 305 -2.8 0 -2.2 -2.9 05/19/2005 00:10:00 5.3 0.8 6.8 3 4.7 1 6.8 2.6 257 9 256 305 -2.8 0 -2.4 -2.7 05/19/2005 00:20:00 4.9 0.8 6.8 3 4.2 0.7 6.1 2.3 261 8 263 305 -2.8 0 -2.7 -2.9 05/19/2005 00:30:00 5.5 1 7.2 3.4 4.8 0.8 7.2 3 256 6 261 305 -2.8 0 -2.7 -2.7 05/19/2005 00:40:00 5.4 0.7 6.8 3.4 4.9 0.8 6.5 3.4 253 6 251 305 -2.6 0.1 -2 -2.7 05/19/2005 00:50:00 5.5 0.9 7.2 3.4 5 0.8 6.8 3 253 8 250 305 -2.5 0 -2 -2.7 05/19/2005 01:00:00 6.1 0.8 7.6 3.8 5.1 0.8 6.8 2.6 259 5 261 305 -2.6 0.1 -2.4 -2.7 05/19/2005 01:10:00 5.5 0.8 7.6 3.8 4.9 0.9 7.6 3 254 7 247 305 -2.6 0 -2.4 -2.7 05/19/2005 01:20:00 5.3 1.1 8 2.6 4.9 1.1 7.2 2.3 257 8 250 305 -2.6 0 -2.4 -2.7 05/19/2005 01:30:00 5.8 0.8 7.6 3.4 5.2 0.8 7.2 3 256 9 261 305 -2.5 0 -2.4 -2.7 05/19/2005 01:40:00 6 0.7 7.6 3.8 5.6 0.6 7.6 3.4 250 7 262 305 -2.5 0 -2.4 -2.7 05/19/2005 01:50:00 5.6 0.6 7.2 3.8 5.1 0.7 6.8 3 252 6 245 305 -2.5 0 -2.4 -2.7 05/19/2005 02:00:00 5.7 1 8 3.8 4.9 1 7.2 3 258 8 261 305 -2.5 0 -2.4 -2.7 05/19/2005 02:10:00 6.3 0.7 7.6 4.2 5.4 0.8 8 3 260 10 275 305 -2.5 0 -2.4 -2.7 05/19/2005 02:20:00 6.4 0.8 9.1 4.6 6 0.9 8.8 3.8 251 6 255 305 -2.5 0 -2.4 -2.7 05/19/2005 02:30:00 5.9 0.9 8.4 3.8 5.1 1 7.6 2.6 256 8 247 305 -2.5 0 -2 -2.7 05/19/2005 02:40:00 5.8 0.8 7.6 3 4.8 0.7 6.8 3 260 6 250 305 -2.4 0 -2.4 -2.7 05/19/2005 02:50:00 5.7 0.9 7.6 3.8 5 0.8 7.2 3 255 9 266 305 -2.4 0 -2 -2.4 05/19/2005 03:00:00 5.3 0.8 7.6 3.4 4.9 0.9 7.6 3 249 10 239 305 -2.4 0 -2.2 -2.4 05/19/2005 03:10:00 5.5 0.9 8 3.4 5 1 8 3 248 10 246 305 -2.4 0 -1.8 -2.4 05/19/2005 03:20:00 6 0.8 8 4.2 5.5 0.9 7.6 3.4 250 7 250 305 -2.5 0 -2.2 -2.7 05/19/2005 03:30:00 5.2 1.1 8 2.6 4.5 1 7.2 2.3 257 10 251 305 -2.6 0.1 -2 -2.7 05/19/2005 03:40:00 5.3 0.6 6.5 3.8 4.9 0.6 6.5 3 246 9 247 305 -2.6 0 -2.4 -2.7 05/19/2005 03:50:00 5.7 1 7.6 3 5.2 1 7.2 2.6 248 10 234 305 -2.6 0 -2.4 -2.7 05/19/2005 04:00:00 5.2 0.7 6.8 3 4.6 0.7 7.6 3 255 8 254 305 -2.7 0 -2.4 -2.7 05/19/2005 04:10:00 5.5 1 7.6 3.4 4.8 1 7.6 3 256 6 259 305 -2.8 0 -2.7 -2.9 05/19/2005 04:20:00 5.7 0.6 7.6 4.2 5.4 0.6 7.2 3.8 238 7 236 305 -2.8 0 -2.7 -3.1 05/19/2005 04:30:00 5.2 0.8 8 3.4 5.1 0.8 8 3.4 242 8 243 305 -3 0 -2.2 -3.1 05/19/2005 04:40:00 6.2 0.7 7.6 4.2 5.9 0.8 7.6 3.4 247 8 253 305 -2.9 0 -2.7 -3.1 05/19/2005 04:50:00 4.6 0.9 6.8 3 4.5 0.8 6.5 3 245 6 246 305 -2.8 0 -2.7 -3.1 05/19/2005 05:00:00 5.4 0.8 6.8 3.4 4.9 0.8 6.8 2.6 256 7 259 305 -2.8 0 -2.7 -2.9 05/19/2005 05:10:00 5.1 1.2 7.2 3 4.7 1.2 6.8 2.6 239 7 239 305 -3 0 -2.7 -3.1 05/19/2005 05:20:00 4.4 0.5 5.7 2.6 4.2 0.6 5.7 2.6 227 6 230 305 -2.8 0 -2.4 -3.1 05/19/2005 05:30:00 5.7 0.6 6.8 4.2 5.3 0.6 6.5 3.8 231 6 234 305 -2.8 0 -2.2 -2.9 05/19/2005 05:40:00 6.1 0.5 7.2 4.9 5.7 0.5 7.2 4.6 239 5 245 305 -2.8 0 -2.7 -2.9 05/19/2005 05:50:00 5.5 0.6 6.8 3.4 5.2 0.5 6.5 3.8 238 5 241 305 -2.8 0 -2.7 -2.9 05/19/2005 06:00:00 5.2 0.5 6.1 3.8 5 0.5 6.1 3.8 229 7 239 305 -2.8 0 -2.7 -2.9 05/19/2005 06:10:00 5.5 0.4 6.8 4.6 5.2 0.5 6.5 3.8 227 5 224 305 -2.8 0 -2.4 -2.9 05/19/2005 06:20:00 5.6 0.5 6.8 4.2 5.4 0.6 6.8 3.8 220 5 214 305 -2.8 0 -2.4 -2.9 05/19/2005 06:30:00 5.5 0.5 6.8 3.8 5.3 0.5 6.8 3.8 222 7 228 305 -2.7 0 -2.7 -2.9 05/19/2005 06:40:00 5.4 0.6 6.8 3.8 5.2 0.6 6.5 3.8 225 5 223 305 -2.6 0 -2.4 -2.7 05/19/2005 06:50:00 6 0.5 7.2 4.6 5.7 0.6 6.8 4.2 220 6 232 305 -2.6 0 -2.4 -2.7 05/19/2005 07:00:00 6 0.7 7.6 4.2 5.7 0.7 7.2 3.8 225 6 227 305 -2.6 0 -2.4 -2.7 05/19/2005 07:10:00 6.1 0.7 7.6 3.8 5.8 0.8 7.6 3.8 230 5 221 305 -2.6 0 -2.4 -2.7 05/19/2005 07:20:00 6.2 0.7 7.6 4.6 5.9 0.7 7.6 4.2 230 6 222 305 -2.5 0 -2.4 -2.7 05/19/2005 07:30:00 6.4 0.7 7.6 4.2 6.1 0.7 7.6 3.8 232 6 231 305 -2.4 0 -2.2 -2.7 05/19/2005 07:40:00 5.8 0.8 8 4.2 5.6 0.8 7.6 3.8 231 7 247 305 -2.3 0 -2.2 -2.4 05/19/2005 07:50:00 6 0.7 8 4.2 5.6 0.8 7.6 3.8 233 8 227 305 -2.3 0 -2.2 -2.4 05/19/2005 08:00:00 6.1 0.5 7.2 4.6 5.8 0.5 6.8 4.6 223 5 220 305 -2.3 0 -2.2 -2.4 05/19/2005 08:10:00 5.8 0.7 7.2 3.8 5.5 0.8 7.2 3.8 238 7 221 305 -2.4 0 -2.2 -2.7 05/19/2005 08:20:00 5.3 0.7 6.8 3 5.1 0.7 6.8 3.4 231 10 237 305 -2.5 0 -2.2 -2.7 05/19/2005 08:30:00 5.3 0.7 6.8 3.4 5.1 0.8 6.8 3 222 8 221 305 -2.4 0 -2.2 -2.7 05/19/2005 08:40:00 5.8 0.9 8 3.8 5.7 0.9 8 3.8 228 5 226 305 -2.6 0.1 -2.4 -2.7 05/19/2005 08:50:00 6.1 0.7 8 4.2 6 0.8 7.6 3.8 220 6 227 305 -2.6 0 -2.4 -2.7 05/19/2005 09:00:00 6.4 0.8 8 3.8 6.3 0.9 8 4.2 211 8 204 305 -2.7 0 -2.7 -2.9 05/19/2005 09:10:00 6.5 0.6 8 4.9 6.3 0.7 8 4.2 214 6 218 305 -2.7 0 -2.4 -2.9 05/19/2005 09:20:00 6.5 0.6 7.6 4.6 6.2 0.7 7.6 4.2 219 8 213 305 -2.7 0 -2.4 -2.7 05/19/2005 09:30:00 6.4 0.8 8 4.2 6.2 0.8 8 4.2 220 6 224 305 -2.6 0.1 -2.4 -2.7 05/19/2005 09:40:00 6.5 0.7 8 4.6 6.3 0.8 8 4.2 225 6 231 305 -2.4 0 -2.2 -2.7 05/19/2005 09:50:00 6.6 0.6 8.4 4.9 6.3 0.7 8 4.2 228 5 233 305 -2.4 0 -2.2 -2.7 05/19/2005 10:00:00 6.2 0.8 7.6 4.6 6 0.8 7.6 4.2 222 8 238 305 -2.4 0 -2 -2.7 05/19/2005 10:10:00 5.8 0.6 7.6 4.2 5.6 0.7 7.6 3.8 228 6 218 305 -2.3 0 -2 -2.4 05/19/2005 10:20:00 6.5 0.6 8 4.9 6.2 0.7 8.4 4.6 232 5 241 305 -2.3 0 -2 -2.4 05/19/2005 10:30:00 6 0.5 7.2 4.2 5.9 0.6 7.2 4.2 215 5 224 305 -2.2 0 -2 -2.4 05/19/2005 10:40:00 5.8 0.8 7.2 3.8 5.6 0.9 7.2 3.4 217 6 218 305 -2 0 -1.8 -2 05/19/2005 10:50:00 5.9 0.8 7.6 3.8 5.6 0.8 7.2 3.8 220 5 224 305 -1.8 0 -1.5 -2 05/19/2005 11:00:00 5.7 0.8 7.6 3.8 5.6 0.9 7.6 3.4 222 6 213 305 -1.9 0 -1.8 -2 05/19/2005 11:10:00 5.7 0.4 6.8 4.2 5.5 0.5 6.5 3.8 219 5 226 305 -1.7 0 -1.3 -1.8 05/19/2005 11:20:00 5.5 0.5 6.8 3.8 5.3 0.6 6.5 4.2 230 7 233 305 -1.5 0 -1.3 -1.8 05/19/2005 11:30:00 5.3 0.5 6.5 3.8 5.1 0.5 6.1 3.4 224 8 215 305 -1.2 0.2 -0.6 -1.8 05/19/2005 11:40:00 4.9 0.6 6.5 3.4 4.8 0.6 6.5 3.4 223 7 222 305 -1.1 0.1 -0.4 -1.3 05/19/2005 11:50:00 5.2 0.7 6.8 3.4 5.1 0.8 6.5 3.4 217 10 205 305 -0.8 0.1 0.1 -1.1 05/19/2005 12:00:00 5.2 0.6 6.5 3.4 5.1 0.6 6.5 3 222 8 227 305 -0.8 0.1 -0.4 -1.1 05/19/2005 12:10:00 6.2 0.5 7.2 4.6 6 0.6 7.2 4.6 231 5 245 305 -1 0.1 -0.4 -1.1 05/19/2005 12:20:00 6.1 0.6 7.2 4.6 5.9 0.6 7.6 4.2 228 6 230 305 -0.9 0.2 0.1 -1.1 05/19/2005 12:30:00 6 0.6 7.6 4.6 5.8 0.6 7.2 3.8 227 5 224 305 -0.6 0.1 0.1 -0.8 05/19/2005 12:40:00 6.2 0.6 7.6 4.6 5.9 0.7 7.6 3.8 223 7 221 305 -0.5 0.1 0.1 -0.8 05/19/2005 12:50:00 6.2 0.5 7.6 4.9 5.9 0.6 8 4.2 223 5 224 305 -0.2 0.1 0.3 -0.4 05/19/2005 13:00:00 5.7 0.6 7.6 3.8 5.4 0.7 7.2 3.8 228 9 236 305 -0.1 0.2 0.6 -0.4 05/19/2005 13:10:00 6 0.6 7.2 4.2 5.8 0.7 7.2 4.2 226 6 226 305 -0.2 0.2 0.3 -0.4 05/19/2005 13:20:00 5.4 0.6 6.8 3.8 5.1 0.6 6.5 3.8 223 8 231 305 0 0.1 0.6 -0.4 05/19/2005 13:30:00 5.3 0.6 6.8 3 5.1 0.6 6.5 3.4 226 8 235 305 0 0.1 0.6 -0.4 05/19/2005 13:40:00 5.7 0.7 7.2 3.8 5.4 0.7 7.2 3.8 223 8 216 305 0.2 0.2 0.8 0.1 05/19/2005 13:50:00 5.6 0.7 7.6 3.4 5.5 0.8 7.6 3.4 221 8 225 305 0.2 0.2 0.8 -0.1 05/19/2005 14:00:00 5.9 0.6 6.8 3.8 5.6 0.6 6.8 4.2 221 8 221 305 0.2 0.2 0.8 -0.4 05/19/2005 14:10:00 5.4 0.7 7.6 3.4 5.2 0.7 6.8 3.4 215 9 218 305 0.3 0.2 1 0.1 05/19/2005 14:20:00 5.1 0.6 7.2 3.8 5 0.6 7.2 3.8 219 6 218 305 0.6 0.2 1 0.6 05/19/2005 14:30:00 4.9 0.5 6.1 3.4 4.9 0.5 6.1 3.8 220 6 215 305 0.9 0.1 1.3 0.6 05/19/2005 14:40:00 5.4 0.6 7.2 4.2 5.2 0.6 6.8 3.4 221 6 223 305 1 0.2 1.5 0.6 05/19/2005 14:50:00 6.1 0.6 7.2 3.8 5.9 0.7 7.6 3.8 224 7 231 305 0.6 0.2 1.3 0.1 05/19/2005 15:00:00 5.6 0.6 7.6 3.8 5.5 0.7 6.8 3.4 225 11 239 305 0.2 0.1 0.8 0.1 05/19/2005 15:10:00 5.2 1 7.2 3.4 5.1 1 7.2 3.4 219 7 210 305 0.6 0.2 1 0.3 05/19/2005 15:20:00 4.9 0.5 6.1 3 4.8 0.5 5.7 3.4 223 6 231 305 0.7 0.2 1.3 0.3 05/19/2005 15:30:00 4.8 0.6 6.1 3.8 4.7 0.6 5.7 3 221 7 218 305 1 0.2 1.5 0.6 05/19/2005 15:40:00 5.5 0.6 7.2 3.8 5.3 0.5 6.8 3.8 221 5 222 305 0.8 0.2 1.5 0.6 05/19/2005 15:50:00 5.8 0.6 7.2 4.6 5.6 0.6 8 4.6 226 7 216 305 0.6 0 1 0.3 05/19/2005 16:00:00 5.7 0.8 7.6 4.2 5.6 0.9 7.6 3.8 220 5 214 305 0.7 0.2 1.5 0.3 05/19/2005 16:10:00 5.5 0.7 8 4.2 5.4 0.7 7.2 3.4 220 6 227 305 0.7 0.1 1.3 0.6 05/19/2005 16:20:00 5.9 0.5 6.8 4.2 5.7 0.6 6.8 4.2 225 8 228 305 0.4 0 0.8 0.3 05/19/2005 16:30:00 5.7 0.6 7.2 4.2 5.5 0.6 6.8 3.8 226 7 222 305 0.5 0 1 0.6 05/19/2005 16:40:00 5.2 0.8 6.8 3.4 4.9 0.8 6.8 3 227 7 223 305 0.6 0.1 1 0.6 05/19/2005 16:50:00 5.2 0.5 6.5 3.4 5.1 0.6 6.5 3.4 223 6 224 305 0.6 0.1 1 0.3 05/19/2005 17:00:00 4.8 0.5 5.7 3 4.7 0.6 6.1 2.6 214 6 229 305 0.5 0.1 1 0.3 05/19/2005 17:10:00 5 0.5 6.5 3 4.9 0.6 6.1 3 214 6 198 305 0.4 0 1 0.3 05/19/2005 17:20:00 5.7 0.6 7.2 4.2 5.5 0.6 7.2 3.8 223 7 238 305 0.3 0.1 0.8 0.1 05/19/2005 17:30:00 5.5 0.6 6.8 3.8 5.3 0.6 6.8 3.4 224 6 221 305 0.3 0.1 0.6 0.1 05/19/2005 17:40:00 5.6 0.7 7.2 3.4 5.4 0.7 6.8 3.4 224 6 232 305 0.2 0.2 0.6 0.1 05/19/2005 17:50:00 4.7 0.7 6.5 3 4.5 0.7 6.5 3 228 7 234 305 0.2 0.1 0.6 0.1 05/19/2005 18:00:00 4.7 0.5 6.1 3.4 4.6 0.5 5.7 3 225 8 228 305 0 0.1 0.6 -0.1 05/19/2005 18:10:00 4.7 0.7 6.1 3 4.5 0.8 6.1 3 226 7 227 305 0 0.1 0.6 -0.1 05/19/2005 18:20:00 4.9 0.7 6.8 3 4.7 0.7 7.2 3 220 8 220 305 0 0 0.6 -0.4 05/19/2005 18:30:00 4.6 0.8 6.1 2.6 4.4 0.7 5.7 2.6 238 5 237 305 -0.2 0 0.3 -0.4 05/19/2005 18:40:00 4.1 0.7 5.7 2.3 3.9 0.6 5.3 2.6 227 12 232 305 -0.2 0 0.3 -0.4 05/19/2005 18:50:00 3.9 0.6 5.3 2.6 3.8 0.6 4.9 2.6 221 10 209 305 -0.1 0 0.3 -0.4 05/19/2005 19:00:00 3.8 0.6 5.7 2.3 3.8 0.6 5.7 2.6 216 6 210 305 -0.1 0 0.3 -0.4 05/19/2005 19:10:00 3.4 0.6 4.6 2.3 3.4 0.6 4.9 2.3 213 9 213 305 -0.1 0.1 0.3 -0.4 05/19/2005 19:20:00 3.7 0.5 4.9 2.6 3.6 0.4 4.9 2.6 218 9 227 305 -0.1 0 0.3 -0.4 05/19/2005 19:30:00 4 0.6 5.7 2.3 3.8 0.6 4.9 2.3 225 10 222 305 -0.2 0 0.3 -0.4 05/19/2005 19:40:00 4.2 0.5 5.3 3 4.2 0.5 5.3 3 210 8 217 305 -0.3 0.1 0.3 -0.4 05/19/2005 19:50:00 4.4 0.6 5.3 3 4.4 0.5 5.7 3 213 9 208 305 -0.4 0.1 0.1 -0.6 05/19/2005 20:00:00 3.8 0.6 4.9 2.3 3.7 0.7 4.9 1.9 213 7 212 305 -0.4 0.1 0.1 -0.6 05/19/2005 20:10:00 4 1 5.7 2.3 4 1 5.7 2.3 225 9 221 305 -0.5 0.1 0.1 -0.6 05/19/2005 20:20:00 3.7 0.6 5.7 2.6 3.7 0.6 5.7 2.3 225 7 214 305 -0.6 0.1 -0.1 -0.6 05/19/2005 20:30:00 2.9 0.4 4.2 1.9 2.9 0.4 4.2 2.3 218 8 217 305 -0.5 0.1 0.1 -0.6 05/19/2005 20:40:00 3.2 0.6 4.6 1.9 3.3 0.6 5.3 1.9 215 8 210 305 -0.5 0.1 0.1 -0.6 05/19/2005 20:50:00 3.7 0.7 5.3 1.9 3.6 0.7 5.3 2.3 213 13 202 305 -0.6 0 0.1 -0.8 05/19/2005 21:00:00 3.5 0.8 5.3 1.9 3.5 0.8 5.3 1.9 217 9 208 305 -0.7 0.1 -0.4 -1.1 05/19/2005 21:10:00 2.7 0.5 4.2 1.5 2.8 0.5 4.2 1.5 207 9 213 305 -0.7 0 -0.4 -1.1 05/19/2005 21:20:00 3.4 0.7 4.6 1.5 3.3 0.7 4.6 1.9 216 9 220 305 -0.7 0 0.1 -0.8 05/19/2005 21:30:00 3.4 0.5 4.9 2.3 3.4 0.5 4.6 2.3 223 7 214 305 -0.7 0 -0.4 -0.8 05/19/2005 21:40:00 3.8 0.6 5.3 2.3 3.8 0.5 5.3 2.3 221 6 218 305 -0.8 0 -0.4 -1.1 05/19/2005 21:50:00 3.4 0.4 4.6 2.3 3.4 0.4 4.6 2.3 214 8 197 305 -0.8 0 -0.4 -1.1 05/19/2005 22:00:00 3.2 0.4 4.2 1.5 3.2 0.4 4.6 2.3 218 11 217 305 -0.8 0 -0.4 -1.1 05/19/2005 22:10:00 3.7 0.6 4.9 2.6 3.7 0.6 4.9 2.3 206 11 209 305 -0.8 0 -0.4 -0.8 05/19/2005 22:20:00 3.7 0.9 5.3 1.5 3.6 1 5.7 1.5 212 13 192 305 -0.8 0 -0.4 -1.1 05/19/2005 22:30:00 3.3 0.4 4.6 1.9 3.3 0.4 4.2 2.3 212 9 203 305 -0.8 0 -0.4 -1.1 05/19/2005 22:40:00 3 0.6 4.9 1.5 3 0.6 4.6 1.9 212 8 212 305 -0.8 0 -0.4 -1.1 05/19/2005 22:50:00 3.2 0.5 4.2 1.9 3.2 0.5 4.6 1.9 212 9 216 305 -0.7 0 -0.4 -1.1 05/19/2005 23:00:00 4.2 0.6 5.7 2.6 4.2 0.7 6.1 2.6 209 7 202 305 -0.8 0.1 -0.4 -1.1 05/19/2005 23:10:00 3.9 0.5 5.7 2.6 4 0.5 5.7 2.6 198 9 211 305 -0.8 0.1 -0.4 -1.1 05/19/2005 23:20:00 3.1 0.7 4.6 1.5 3.2 0.6 4.6 1.9 198 11 197 305 -0.8 0.1 -0.4 -1.1 05/19/2005 23:30:00 2.6 0.4 3.4 1.5 2.8 0.4 3.8 1.9 193 5 193 305 -0.8 0.1 -0.4 -1.1 05/19/2005 23:40:00 2.9 0.8 5.3 1.5 2.9 0.7 5.3 1.9 202 7 213 305 -0.8 0.1 -0.4 -1.1 05/19/2005 23:50:00 3 0.6 4.9 1.9 3.1 0.5 4.9 1.9 213 12 219 305 -0.8 0 -0.4 -1.1 05/20/2005 00:00:00 3.3 0.5 4.6 1.5 3.5 0.5 4.6 1.9 198 14 183 305 -0.8 0 0.1 -1.1 05/20/2005 00:10:00 3.1 0.7 4.9 1.9 3.3 0.7 5.3 1.9 201 9 195 305 -0.8 0 -0.4 -1.1 05/20/2005 00:20:00 3.1 0.5 4.6 1.9 3.2 0.5 4.2 2.3 202 8 211 305 -0.8 0 -0.4 -1.1 05/20/2005 00:30:00 3.6 0.6 5.3 2.3 3.6 0.7 5.3 2.3 208 14 210 305 -0.8 0.1 -0.4 -1.1 05/20/2005 00:40:00 3.2 0.5 4.2 1.9 3.3 0.4 4.2 2.3 202 9 203 305 -0.8 0 -0.4 -1.1 05/20/2005 00:50:00 3.3 0.6 5.3 2.3 3.4 0.6 5.7 2.3 199 5 209 305 -0.8 0.1 -0.4 -1.1 05/20/2005 01:00:00 3.2 0.5 4.6 2.3 3.2 0.5 4.6 2.3 204 7 212 305 -1 0 -0.4 -1.1 05/20/2005 01:10:00 3.1 0.6 4.2 1.9 3.1 0.6 4.6 1.9 207 10 201 305 -1 0.1 -0.4 -1.1 05/20/2005 01:20:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.9 209 7 196 305 -1 0.1 -0.4 -1.1 05/20/2005 01:30:00 3.8 0.6 4.9 2.3 3.8 0.6 4.9 2.3 201 7 219 305 -1 0.1 -0.4 -1.1 05/20/2005 01:40:00 3.3 0.5 4.9 1.9 3.2 0.5 4.6 1.9 206 12 203 305 -0.9 0.1 -0.4 -1.1 05/20/2005 01:50:00 3.3 0.4 4.2 1.9 3.4 0.4 4.2 2.3 202 5 210 305 -1 0.1 -0.4 -1.1 05/20/2005 02:00:00 3.6 0.6 4.9 2.3 3.6 0.6 4.9 1.9 217 10 231 305 -1.1 0.1 -0.6 -1.1 05/20/2005 02:10:00 3.3 0.8 5.7 1.5 3.3 0.8 5.7 1.9 215 9 205 305 -1.1 0 -0.6 -1.3 05/20/2005 02:20:00 3.3 0.6 4.6 1.9 3.4 0.6 4.6 1.9 204 11 205 305 -1.2 0 -0.6 -1.3 05/20/2005 02:30:00 2.4 0.7 4.2 0.7 2.8 0.7 4.6 1.1 194 16 186 305 -1.2 0 -0.6 -1.3 05/20/2005 02:40:00 2 0.4 3 0.7 2.2 0.4 3 1.5 208 10 218 305 -1.1 0.1 -0.6 -1.3 05/20/2005 02:50:00 2.9 0.5 4.6 1.9 2.9 0.4 4.6 1.9 210 7 196 305 -1.1 0 -0.6 -1.3 05/20/2005 03:00:00 2.6 0.5 3.8 1.5 2.7 0.5 4.2 1.9 206 8 201 305 -1.1 0 -0.6 -1.3 05/20/2005 03:10:00 3.5 0.6 5.3 1.9 3.5 0.5 5.3 1.9 203 9 199 305 -1.2 0 -0.6 -1.3 05/20/2005 03:20:00 3.5 0.8 5.3 1.5 3.5 0.9 5.3 1.5 211 15 188 305 -1.4 0 -0.8 -1.5 05/20/2005 03:30:00 2.9 1 5.3 0.7 2.9 0.9 5.3 1.5 213 8 212 305 -1.4 0 -0.8 -1.5 05/20/2005 03:40:00 3.3 0.6 4.6 1.9 3.4 0.5 4.9 2.3 197 8 188 305 -1.4 0 -1.1 -1.5 05/20/2005 03:50:00 3 0.6 4.6 1.5 3.1 0.6 4.6 1.5 195 8 194 305 -1.4 0 -1.1 -1.5 05/20/2005 04:00:00 2 0.5 3 0.7 2 0.5 3 1.1 210 8 203 305 -1.4 0 -1.1 -1.5 05/20/2005 04:10:00 3.4 0.7 5.3 1.5 3.6 0.6 5.3 2.3 202 6 196 305 -1.4 0 -1.3 -1.5 05/20/2005 04:20:00 3.6 0.6 4.9 2.3 3.7 0.6 4.9 2.6 200 8 196 305 -1.4 0 -0.8 -1.5 05/20/2005 04:30:00 3.4 0.7 4.9 1.5 3.5 0.7 5.3 1.9 205 11 197 305 -1.5 0 -1.3 -1.8 05/20/2005 04:40:00 3.6 0.8 5.3 1.9 3.6 0.8 5.3 1.9 212 8 205 305 -1.6 0 -1.5 -1.8 05/20/2005 04:50:00 3.2 0.6 4.6 1.9 3.2 0.5 4.6 1.9 200 10 189 305 -1.7 0 -1.1 -1.8 05/20/2005 05:00:00 2.7 0.6 4.6 1.5 2.8 0.5 4.2 1.5 213 10 212 305 -1.7 0 -1.8 -1.8 05/20/2005 05:10:00 2.4 0.6 3.8 1.1 2.4 0.5 3.8 1.1 222 9 218 305 -1.7 0 -1.8 -1.8 05/20/2005 05:20:00 2.9 0.6 4.2 1.5 3.1 0.5 4.2 1.9 206 13 208 305 -1.7 0 -1.8 -1.8 05/20/2005 05:30:00 2.6 0.7 4.2 0.7 2.9 0.5 4.2 1.5 188 8 184 305 -1.8 0 -1.8 -2 05/20/2005 05:40:00 2.5 0.6 3.8 1.1 3 0.5 4.6 1.9 184 7 197 305 -1.8 0 -1.8 -2 05/20/2005 05:50:00 1.5 1 3.4 0.4 1.9 0.8 3.8 0.7 183 15 189 305 -1.9 0 -1.8 -2 05/20/2005 06:00:00 2.2 0.5 3.4 0.7 2.3 0.4 3.4 1.1 208 12 208 305 -1.9 0 -1.8 -2 05/20/2005 06:10:00 3.3 0.5 4.6 1.5 3.3 0.5 4.6 1.5 203 12 198 305 -1.9 0 -1.8 -2 05/20/2005 06:20:00 1.4 1 3.8 0.4 1.6 1 4.2 0.4 211 18 214 305 -2 0 -2 -2 05/20/2005 06:30:00 2.9 0.5 4.2 1.9 3 0.5 4.2 1.9 215 11 205 305 -2.2 0 -2 -2.4 05/20/2005 06:40:00 1.8 0.6 3 0.4 2 0.6 3.4 0.7 222 13 226 305 -2.3 0 -2.2 -2.4 05/20/2005 06:50:00 0.7 0.4 1.9 0.4 1.2 0.5 2.3 0.4 190 26 186 305 -2.2 0 -1.8 -2.4 05/20/2005 07:00:00 2.1 0.4 3.4 1.1 2.6 0.4 3.8 1.5 170 20 156 305 -2.2 0 -2 -2.2 05/20/2005 07:10:00 1.1 0.7 2.6 0.4 1.3 0.7 2.6 0.4 184 38 192 305 -2.2 0 -2 -2.2 05/20/2005 07:20:00 2 0.5 3.4 0.7 2.4 0.4 3.8 1.5 170 30 190 305 -2.1 0 -1.8 -2.2 05/20/2005 07:30:00 1.1 0.6 2.6 0.4 1.4 0.5 2.6 0.4 231 43 245 305 -2.1 0 -1.5 -2.2 05/20/2005 07:40:00 1.5 0.5 3 0.4 2.1 0.4 3 1.5 176 15 193 305 -2 0 -2 -2.2 05/20/2005 07:50:00 1.3 0.5 2.6 0.4 1.8 0.4 3 1.1 167 26 183 305 -2.2 0 -2 -2.2 05/20/2005 08:00:00 1.2 0.6 3 0.4 1.7 0.5 3.4 0.7 170 29 189 305 -2.1 0 -1.8 -2.2 05/20/2005 08:10:00 2 0.6 3.4 0.4 2.2 0.6 3.4 1.1 202 13 206 305 -2.2 0 -2 -2.4 05/20/2005 08:20:00 1.6 0.6 2.6 0.4 1.9 0.5 3 0.7 218 12 216 305 -2.3 0 -2.2 -2.4 05/20/2005 08:30:00 1.2 0.6 2.3 0.4 1.7 0.6 2.6 0.4 170 30 146 305 -2.1 0.1 -2 -2.4 05/20/2005 08:40:00 2.2 0.7 3.8 0.7 2.5 0.6 3.8 1.1 132 8 124 305 -1.9 0 -1.8 -2 05/20/2005 08:50:00 1.3 0.6 2.6 0.4 1.7 0.5 2.6 0.7 96 20 124 305 -1.8 0 -1.8 -2 05/20/2005 09:00:00 1.1 0.6 2.6 0.4 1.6 0.6 3 0.4 128 51 180 305 -1.7 0 -1.5 -2 05/20/2005 09:10:00 0.8 0.5 2.6 0.4 1.4 0.4 2.6 0.4 162 13 181 305 -1.6 0.1 -1.3 -2 05/20/2005 09:20:00 1.5 0.6 3 0.4 1.9 0.5 3 0.7 119 22 128 305 -1.4 0 -1.3 -1.5 05/20/2005 09:30:00 2.1 0.4 3 0.7 2.7 0.4 3.4 1.5 161 10 172 305 -1.5 0 -1.3 -1.8 05/20/2005 09:40:00 1.4 0.7 3.4 0.4 1.8 0.6 3.4 0.7 150 19 165 305 -1.5 0 -0.8 -1.8 05/20/2005 09:50:00 2.2 0.7 4.2 0.7 2.7 0.6 4.2 1.5 159 9 150 305 -1.5 0.1 -1.1 -1.8 05/20/2005 10:00:00 1.7 0.6 3.4 0.4 2.2 0.5 3.4 1.1 160 16 156 305 -1.4 0.1 -0.8 -1.8 05/20/2005 10:10:00 1.9 0.7 3.8 0.4 2.4 0.7 4.2 0.7 159 19 157 305 -1.5 0.1 -1.1 -1.8 05/20/2005 10:20:00 1.8 0.7 3.8 0.4 2.4 0.6 3.8 0.7 172 19 137 305 -1.7 0.1 -1.1 -2 05/20/2005 10:30:00 2.7 0.6 4.6 1.1 2.8 0.6 4.2 1.5 125 13 158 305 -1.3 0.1 -1.1 -1.8 05/20/2005 10:40:00 2.4 0.7 4.2 0.7 2.7 0.6 4.2 1.1 145 15 148 305 -1.2 0 -0.6 -1.8 05/20/2005 10:50:00 2 0.6 3.8 0.4 2.3 0.5 3.4 1.1 148 18 111 305 -1.3 0 -0.6 -1.8 05/20/2005 11:00:00 1.9 0.6 3.8 0.4 2.4 0.6 3.8 0.7 157 23 179 305 -1 0 -0.8 -1.1 05/20/2005 11:10:00 1.8 0.6 3.4 0.4 2.3 0.6 4.2 1.1 178 15 192 305 -1.5 0.1 -0.6 -1.8 05/20/2005 11:20:00 1.6 0.9 3.8 0.4 2.1 0.7 3.8 0.7 170 21 141 305 -1.2 0.1 -0.6 -1.5 05/20/2005 11:30:00 1.6 0.4 2.6 0.4 2.1 0.4 3 0.7 155 22 156 305 -1 0.1 -0.4 -1.1 05/20/2005 11:40:00 1.4 0.6 3 0.4 2 0.5 3.8 0.7 179 20 161 305 -1 0.1 -0.4 -1.1 05/20/2005 11:50:00 1.7 1 3.8 0.4 2 0.8 3.8 0.4 189 43 227 305 -0.8 0.1 -0.4 -1.3 05/20/2005 12:00:00 2.4 0.6 3.8 1.1 2.5 0.5 3.8 1.1 232 9 225 305 -1.2 0 -0.6 -1.5 05/20/2005 12:10:00 3 0.4 3.8 1.9 3.1 0.4 3.8 2.3 219 7 227 305 -1.2 0 -0.8 -1.5 05/20/2005 12:20:00 2.7 0.6 3.8 0.7 2.9 0.5 3.8 1.5 224 8 243 305 -1.2 0.1 -0.6 -1.5 05/20/2005 12:30:00 2.3 0.6 4.2 1.1 2.4 0.5 3.8 1.5 221 12 203 305 -1.4 0 -0.8 -1.8 05/20/2005 12:40:00 1.6 0.5 2.6 0.4 1.8 0.4 3 0.7 227 21 232 305 -1.1 0.1 -0.6 -1.3 05/20/2005 12:50:00 1.3 0.5 2.6 0.4 1.7 0.5 2.6 0.4 220 13 231 305 -0.8 0.1 -0.4 -1.1 05/20/2005 13:00:00 1.4 0.7 3 0.4 1.6 0.6 3 0.4 226 53 224 305 -0.5 0.1 0.1 -0.8 05/20/2005 13:10:00 1.9 0.5 3 0.4 2.1 0.4 3.4 1.1 224 12 244 305 -0.5 0.1 0.1 -0.6 05/20/2005 13:20:00 1.3 0.5 2.3 0.4 1.6 0.5 3 0.4 208 14 205 305 -0.2 0.2 0.6 -0.6 05/20/2005 13:30:00 1.2 0.5 2.6 0.4 1.5 0.5 2.6 0.4 183 23 179 305 0.2 0.1 0.6 0.1 05/20/2005 13:40:00 1.4 0.6 3 0.4 1.7 0.6 3.4 0.4 146 20 131 305 0.7 0.2 1.5 0.3 05/20/2005 13:50:00 0.7 0.5 2.3 0.4 1.3 0.5 3 0.4 145 15 76 305 1.2 0.1 1.7 1 05/20/2005 14:00:00 0.9 0.5 2.3 0.4 1.2 0.5 2.6 0.4 119 22 116 305 1.4 0.1 2 1 05/20/2005 14:10:00 1.2 0.7 3 0.4 1.8 0.7 3 0.4 350 33 356 305 0.6 0.1 1.3 0.3 05/20/2005 14:20:00 1.8 0.6 3.4 0.4 2.1 0.5 3.4 0.4 279 66 225 305 0.4 0 1 0.3 05/20/2005 14:30:00 1.3 0.7 2.6 0.4 1.5 0.8 3 0.4 164 41 139 305 0.9 0.3 1.7 0.3 05/20/2005 14:40:00 2 0.5 3.8 0.7 2.4 0.6 4.2 0.7 168 24 150 305 0.9 0.4 2 0.3 05/20/2005 14:50:00 1.8 0.6 3.4 0.7 2.3 0.6 4.2 1.1 161 17 156 305 1 0.1 1.5 0.8 05/20/2005 15:00:00 3.5 0.4 4.6 2.3 3.6 0.4 4.6 2.3 134 8 127 305 1.3 0.1 1.7 1 05/20/2005 15:10:00 3.7 0.4 4.6 1.9 3.8 0.4 4.9 2.6 135 9 127 305 1.4 0.1 2 1.3 05/20/2005 15:20:00 3.7 0.7 4.9 1.5 3.8 0.7 5.7 1.9 140 13 145 305 1.4 0.2 2 1 05/20/2005 15:30:00 4.2 0.5 5.3 2.3 4.2 0.5 5.3 2.6 132 8 137 305 1.5 0.2 2.2 1 05/20/2005 15:40:00 4.3 0.5 5.3 3 4.3 0.5 5.7 3 134 8 137 305 1.6 0.1 2 1.3 05/20/2005 15:50:00 4.5 0.6 6.1 3 4.6 0.6 6.1 3 137 8 137 305 1.2 0.2 2 1 05/20/2005 16:00:00 4.8 0.6 6.1 3 4.8 0.6 6.1 3 134 6 135 305 1.3 0.2 1.7 1 05/20/2005 16:10:00 4.9 0.5 6.1 3.4 4.9 0.5 6.1 3.4 135 7 141 305 1.2 0.2 1.7 0.8 05/20/2005 16:20:00 5.2 0.6 6.5 3 5.2 0.6 6.5 3.4 134 5 137 305 1.3 0.2 2 1 05/20/2005 16:30:00 5.3 0.5 6.5 3.8 5.3 0.5 6.5 4.2 133 5 137 305 1.2 0.2 1.7 1 05/20/2005 16:40:00 5.6 0.5 7.2 3.8 5.7 0.5 7.2 3.4 131 6 137 305 1.2 0.1 1.5 1 05/20/2005 16:50:00 5.6 0.4 6.5 4.6 5.7 0.4 6.5 4.6 133 5 127 305 1 0.1 1.5 0.6 05/20/2005 17:00:00 5.3 0.5 6.5 3.8 5.5 0.5 6.5 4.2 139 5 138 305 0.6 0 1 0.3 05/20/2005 17:10:00 5.1 0.5 6.5 3.4 5.2 0.5 6.5 3.8 137 6 129 305 0.6 0.1 1 0.3 05/20/2005 17:20:00 5.3 0.4 6.1 4.2 5.3 0.5 6.1 4.2 136 5 134 305 0.6 0 1 0.3 05/20/2005 17:30:00 5 0.4 5.7 3.4 5.1 0.4 6.1 3.8 140 4 145 305 0.5 0 1 0.3 05/20/2005 17:40:00 5.3 0.4 6.1 4.2 5.4 0.4 6.1 3.8 137 5 145 305 0.5 0 1 0.3 05/20/2005 17:50:00 5.3 0.5 6.5 3.8 5.4 0.4 6.1 3.8 137 5 137 305 0.6 0.1 1 0.3 05/20/2005 18:00:00 5.6 0.4 6.5 4.6 5.7 0.4 6.5 4.6 138 4 138 305 0.7 0.1 1.3 0.3 05/20/2005 18:10:00 6 0.4 6.8 4.6 6.1 0.4 7.2 4.6 137 4 138 305 0.6 0.1 1 0.3 05/20/2005 18:20:00 6.2 0.4 7.2 4.6 6.3 0.5 7.2 4.6 138 4 139 305 0.4 0.1 1 0.3 05/20/2005 18:30:00 6.6 0.4 7.2 5.3 6.6 0.3 7.6 5.7 133 3 137 305 0.5 0 1 0.3 05/20/2005 18:40:00 6 0.6 7.6 4.2 6.1 0.5 7.6 4.6 134 4 137 305 0.4 0.1 1 0.3 05/20/2005 18:50:00 6.1 0.5 7.2 4.9 6.2 0.5 7.2 4.9 136 5 140 305 0.4 0 1 0.3 05/20/2005 19:00:00 6.1 0.5 7.2 4.6 6.1 0.5 7.2 4.6 134 4 133 305 0.4 0.1 1 0.3 05/20/2005 19:10:00 6.1 0.7 7.2 4.2 6.1 0.6 7.2 4.2 135 4 135 305 0.5 0.1 1 0.3 05/20/2005 19:20:00 6.3 0.5 7.2 4.9 6.3 0.5 7.2 4.9 138 4 137 305 0.4 0 1 0.3 05/20/2005 19:30:00 6.1 0.5 7.2 4.6 6.1 0.5 7.2 4.6 138 5 142 305 0.4 0 1 0.3 05/20/2005 19:40:00 5.8 0.5 6.8 4.6 5.8 0.6 7.2 4.6 143 5 139 305 0.4 0 1 0.3 05/20/2005 19:50:00 5.3 0.7 6.5 3 5.3 0.8 6.8 3.4 148 6 138 305 0.4 0 1 0.3 05/20/2005 20:00:00 4.4 0.8 6.5 2.3 4.6 0.6 6.5 3.4 154 9 151 305 0.4 0 1 0.3 05/20/2005 20:10:00 5 0.9 6.8 2.3 5.2 0.8 7.2 3.4 152 8 151 305 0.5 0 1 0.3 05/20/2005 20:20:00 5.8 0.6 7.2 3.8 5.8 0.6 7.2 4.2 148 6 153 305 0.4 0 1 0.3 05/20/2005 20:30:00 6 0.5 7.2 4.2 6.1 0.6 7.2 4.2 149 5 152 305 0.3 0 0.8 0.1 05/20/2005 20:40:00 5.8 0.7 7.6 4.2 6 0.7 7.2 4.2 147 6 149 305 0.2 0 0.6 0.1 05/20/2005 20:50:00 6.3 0.6 8 4.9 6.3 0.6 8 4.6 150 5 155 305 0.2 0 0.6 0.1 05/20/2005 21:00:00 6.8 0.5 8 5.3 6.9 0.5 8 5.7 147 5 148 305 0.1 0.1 0.6 0.1 05/20/2005 21:10:00 6.8 0.7 8 4.9 6.8 0.6 8 4.2 149 6 151 305 0 0 0.6 -0.1 05/20/2005 21:20:00 6.6 0.8 8.4 3.8 6.5 0.6 8.4 4.6 154 4 156 305 0 0 0.3 -0.1 05/20/2005 21:30:00 6.1 0.9 7.6 3.4 6.2 0.6 7.2 4.2 156 5 158 305 0 0 0.3 -0.1 05/20/2005 21:40:00 5.8 0.6 7.6 3.4 5.8 0.6 7.2 3.8 154 5 156 305 0 0 0.3 -0.1 05/20/2005 21:50:00 5.7 0.7 7.2 3.4 5.7 0.6 7.2 4.2 154 6 155 305 0 0 0.3 -0.1 05/20/2005 22:00:00 5.3 0.9 7.2 2.3 5.8 0.6 7.2 4.2 158 5 156 305 0 0 0.3 -0.4 05/20/2005 22:10:00 5.5 0.7 7.2 3.4 5.8 0.5 6.8 4.2 157 5 157 305 -0.1 0 0.3 -0.4 05/20/2005 22:20:00 5.7 0.7 6.8 3.4 5.7 0.6 6.8 3.8 152 5 156 305 -0.2 0 0.3 -0.4 05/20/2005 22:30:00 6.7 0.6 8.4 4.6 6.7 0.7 8 4.6 149 5 151 305 -0.3 0 0.3 -0.4 05/20/2005 22:40:00 6.3 0.6 7.6 4.2 6.3 0.7 7.6 4.2 150 5 147 305 -0.3 0 0.3 -0.4 05/20/2005 22:50:00 5.8 0.8 7.2 2.6 5.9 0.8 7.6 3.4 151 6 145 305 -0.3 0 0.3 -0.4 05/20/2005 23:00:00 6.1 0.6 7.6 4.6 6.1 0.7 8 4.6 152 4 151 305 -0.3 0 0.3 -0.4 05/20/2005 23:10:00 5.4 1 7.2 3 5.8 0.5 6.8 4.6 157 7 163 305 -0.2 0 0.3 -0.4 05/20/2005 23:20:00 4.5 1 6.8 2.3 5.6 0.5 6.8 4.6 162 7 150 305 -0.1 0 0.3 -0.4 05/20/2005 23:30:00 5.6 0.9 7.6 3 6 0.6 7.6 4.6 156 7 151 305 -0.1 0 0.3 -0.4 05/20/2005 23:40:00 6.2 0.8 8 3.8 6.6 0.5 8 4.6 153 5 149 305 -0.3 0 0.3 -0.4 05/20/2005 23:50:00 6.1 0.9 7.6 3 6.7 0.5 8 5.3 156 5 158 305 -0.3 0 0.3 -0.4 05/21/2005 00:00:00 6.4 0.6 7.6 3.4 6.5 0.5 7.6 4.9 154 4 154 305 -0.3 0 0.3 -0.4 05/21/2005 00:10:00 5.7 1 7.2 2.6 6.2 0.5 7.2 4.6 156 6 147 305 -0.3 0 0.3 -0.4 05/21/2005 00:20:00 4.6 1 6.8 2.6 5.8 0.4 6.8 4.2 161 7 161 305 -0.3 0 0.3 -0.4 05/21/2005 00:30:00 3.8 0.8 6.5 2.3 5.6 0.4 6.5 4.2 164 5 156 305 -0.2 0 0.3 -0.4 05/21/2005 00:40:00 3.6 0.7 5.7 2.3 5.4 0.5 6.5 3.4 167 7 156 305 -0.2 0 0.3 -0.4 05/21/2005 00:50:00 5.6 0.9 6.8 3.4 5.9 0.5 7.2 4.6 155 6 160 305 -0.3 0 0.3 -0.4 05/21/2005 01:00:00 5.6 0.5 6.8 3.4 5.8 0.4 6.8 4.2 150 4 150 305 -0.3 0.1 0.3 -0.4 05/21/2005 01:10:00 6 0.5 7.2 3.8 6 0.5 7.2 4.2 147 3 149 305 -0.4 0.1 0.1 -0.6 05/21/2005 01:20:00 5.7 0.5 7.2 4.2 5.7 0.7 6.8 3.8 150 4 153 305 -0.5 0 0.1 -0.6 05/21/2005 01:30:00 4.7 0.6 6.1 2.6 4.8 0.5 6.1 3.8 155 6 150 305 -0.5 0.1 0.1 -0.6 05/21/2005 01:40:00 4.9 0.8 6.8 3 5.9 0.5 6.8 4.2 160 5 156 305 -0.5 0 0.1 -0.6 05/21/2005 01:50:00 4.9 0.8 7.2 2.6 5.9 0.5 6.8 4.6 161 5 159 305 -0.6 0 0.1 -0.6 05/21/2005 02:00:00 5.2 0.7 6.8 3.8 5.4 0.6 6.5 3.8 156 4 155 305 -0.6 0 0.1 -0.8 05/21/2005 02:10:00 5.5 0.5 6.5 3.8 5.5 0.5 6.5 3.8 150 4 150 305 -0.6 0 0.1 -0.6 05/21/2005 02:20:00 5.6 0.6 6.5 3.4 5.6 0.5 6.5 4.2 153 5 149 305 -0.6 0 -0.1 -0.6 05/21/2005 02:30:00 4.1 0.8 6.5 2.3 5 0.6 6.5 3.4 161 4 159 305 -0.6 0 0.1 -0.8 05/21/2005 02:40:00 4 0.9 6.1 1.9 5.1 0.6 6.5 3.4 164 8 157 305 -0.7 0 0.1 -0.8 05/21/2005 02:50:00 3.6 0.7 5.7 2.3 5.4 0.5 6.8 4.2 167 6 159 305 -0.8 0 -0.4 -1.1 05/21/2005 03:00:00 3.5 0.8 5.7 1.9 5.1 0.4 6.5 3.8 167 6 163 305 -0.7 0 -0.1 -0.8 05/21/2005 03:10:00 3.4 0.6 5.3 2.3 5.1 0.5 6.1 4.2 168 5 162 305 -0.6 0 0.1 -0.6 05/21/2005 03:20:00 3 0.6 4.9 1.9 4.7 0.6 6.1 3 173 5 176 305 -0.5 0.1 0.1 -0.6 05/21/2005 03:30:00 3.1 0.5 4.6 1.5 4 0.3 4.9 3 180 5 183 305 -0.3 0 0.3 -0.4 05/21/2005 03:40:00 2.4 0.5 3.8 0.7 3.1 0.5 4.2 1.9 175 7 186 305 -0.3 0 0.3 -0.4 05/21/2005 03:50:00 2.5 0.5 4.2 1.1 3 0.5 4.2 1.9 180 13 150 305 -0.3 0 0.3 -0.4 05/21/2005 04:00:00 2.5 0.8 4.2 0.7 3 0.6 4.2 1.5 161 15 168 305 -0.4 0.1 0.3 -0.6 05/21/2005 04:10:00 2.6 0.8 4.6 0.7 2.9 0.7 4.6 1.1 149 13 145 305 -0.6 0 0.1 -0.6 05/21/2005 04:20:00 1.9 1 4.2 0.4 2.4 0.8 4.2 0.7 161 19 140 305 -0.5 0 0.1 -0.6 05/21/2005 04:30:00 2.8 0.8 4.6 1.1 3.8 0.5 4.9 2.6 176 7 186 305 -0.4 0 0.1 -0.6 05/21/2005 04:40:00 3.6 0.5 5.3 2.3 4.2 0.5 5.3 3 182 5 188 305 -0.4 0.1 0.1 -0.6 05/21/2005 04:50:00 4.2 0.5 5.3 3 4.4 0.5 5.3 3 186 3 186 305 -0.4 0 0.1 -0.6 05/21/2005 05:00:00 3.4 0.5 4.6 2.3 3.4 0.5 4.6 2.3 188 5 182 305 -0.4 0.1 0.1 -0.6 05/21/2005 05:10:00 3.1 0.3 3.8 2.3 3.2 0.3 3.8 2.3 190 4 190 305 -0.4 0 0.3 -0.4 05/21/2005 05:20:00 3 0.2 3.4 2.3 3.1 0.3 3.8 2.3 196 3 190 305 -0.3 0.1 0.3 -0.4 05/21/2005 05:30:00 2.9 0.3 3.4 2.3 3 0.3 3.8 1.9 192 2 193 305 -0.3 0 0.3 -0.4 05/21/2005 05:40:00 3.3 0.4 4.2 1.9 3.4 0.4 4.2 2.3 188 4 194 305 -0.1 0.1 0.3 -0.4 05/21/2005 05:50:00 3.5 0.3 4.6 2.6 3.6 0.3 4.6 2.6 190 4 189 305 0 0.1 0.6 0.1 05/21/2005 06:00:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.3 189 4 189 305 0.1 0.1 0.6 0.1 05/21/2005 06:10:00 2.9 0.7 4.2 1.1 3.3 0.5 4.6 2.3 186 7 189 305 0.1 0 0.6 0.1 05/21/2005 06:20:00 2.9 0.5 4.2 1.5 3.1 0.4 4.2 1.9 187 5 184 305 0.2 0 0.8 0.1 05/21/2005 06:30:00 2.6 0.4 3.8 1.1 2.7 0.4 3.8 1.5 190 7 194 305 0.2 0 0.6 0.1 05/21/2005 06:40:00 2.6 0.4 3.8 1.9 2.9 0.4 3.8 1.9 196 5 206 305 0.2 0 0.8 0.1 05/21/2005 06:50:00 3.2 0.4 4.6 2.3 3.3 0.4 4.6 2.3 194 6 194 305 0.2 0 0.6 0.1 05/21/2005 07:00:00 3.2 0.4 4.2 2.3 3.4 0.4 4.2 2.3 188 6 189 305 0.3 0 0.8 0.1 05/21/2005 07:10:00 2.9 0.4 3.8 1.9 3.3 0.5 4.2 1.9 182 7 189 305 0.4 0 1 0.3 05/21/2005 07:20:00 3.7 0.3 4.2 3 3.7 0.4 4.6 2.3 190 3 188 305 0.4 0 1 0.3 05/21/2005 07:30:00 3.7 0.2 4.2 3 3.8 0.3 4.6 2.6 191 3 185 305 0.4 0 1 0.3 05/21/2005 07:40:00 3.9 0.2 4.6 3.4 3.9 0.3 4.6 3 192 2 193 305 0.4 0 1 0.3 05/21/2005 07:50:00 4.1 0.3 4.9 3 4.2 0.3 4.9 3.4 195 5 196 305 0.4 0 1 0.3 05/21/2005 08:00:00 4.1 0.3 4.9 3.4 4.1 0.4 4.9 2.6 195 4 191 305 0.4 0 1 0.3 05/21/2005 08:10:00 4.6 0.5 5.7 3.4 4.5 0.5 5.7 3 206 7 210 305 0.2 0.2 0.8 0.1 05/21/2005 08:20:00 4.3 0.4 5.3 3 4.3 0.5 5.3 3 196 4 190 305 0 0 0.1 -0.1 05/21/2005 08:30:00 4.3 0.4 5.3 3 4.3 0.4 5.3 3 193 3 196 305 0 0 0.6 -0.1 05/21/2005 08:40:00 4.7 0.5 5.7 3 4.5 0.6 5.7 3 197 5 197 305 0 0 0.6 -0.1 05/21/2005 08:50:00 5.1 0.5 6.1 3.8 5 0.5 6.1 3.8 196 3 199 305 0.1 0.1 0.6 0.1 05/21/2005 09:00:00 3.7 0.4 4.6 2.6 3.8 0.4 4.6 3 195 3 194 305 0.2 0 0.8 0.1 05/21/2005 09:10:00 4.1 0.6 5.3 3 4 0.6 5.7 2.6 207 5 208 305 0.3 0 0.8 0.1 05/21/2005 09:20:00 4.8 0.4 5.3 3.8 4.8 0.4 5.7 3.4 196 7 205 305 0.1 0.1 0.6 0.1 05/21/2005 09:30:00 4.4 0.4 5.7 3.4 4.6 0.4 6.1 3 191 5 199 305 0.2 0.1 0.6 0.1 05/21/2005 09:40:00 4 0.4 4.9 3 4.2 0.4 4.9 3 188 4 196 305 0.1 0.1 0.6 0.1 05/21/2005 09:50:00 3.6 0.4 4.6 2.6 3.9 0.5 4.9 2.6 185 4 189 305 0.3 0 0.8 0.1 05/21/2005 10:00:00 4.3 0.5 5.3 2.6 4.5 0.5 5.3 3.4 188 5 188 305 0.4 0 0.8 0.3 05/21/2005 10:10:00 4.6 0.5 6.1 3.4 4.5 0.5 6.1 3 191 4 186 305 0.4 0 1 0.1 05/21/2005 10:20:00 4.3 0.8 6.1 2.3 4.4 0.8 6.5 2.3 195 4 196 305 0.3 0 0.8 0.1 05/21/2005 10:30:00 3.9 0.5 4.9 2.6 3.8 0.5 4.9 2.6 196 5 198 305 0.4 0 1 0.3 05/21/2005 10:40:00 3.9 0.5 4.9 2.3 3.8 0.5 4.9 2.6 195 6 192 305 0.4 0 0.8 0.3 05/21/2005 10:50:00 4 0.6 4.9 2.3 3.9 0.6 4.9 2.3 203 9 196 305 0.3 0 0.6 0.1 05/21/2005 11:00:00 4.2 0.7 6.1 2.6 4.1 0.6 6.1 2.6 209 5 211 305 0.2 0 0.6 0.1 05/21/2005 11:10:00 4.3 0.6 5.7 3 4.2 0.6 5.7 3 206 6 217 305 0.2 0 0.6 0.1 05/21/2005 11:20:00 4.4 0.5 5.7 3 4.3 0.5 5.7 3 206 7 213 305 0.3 0 0.8 0.1 05/21/2005 11:30:00 4.8 0.6 6.5 3 4.7 0.6 5.7 3 205 6 212 305 0.2 0.1 0.6 0.1 05/21/2005 11:40:00 4.4 0.5 5.3 3 4.4 0.5 5.3 3 205 6 198 305 0.2 0.1 0.6 0.1 05/21/2005 11:50:00 4.2 0.5 5.3 3 4.2 0.5 5.3 2.6 206 6 213 305 0.3 0 0.8 0.1 05/21/2005 12:00:00 4.9 0.5 6.1 3.4 4.7 0.6 5.7 3 211 6 211 305 0.4 0 1 0.3 05/21/2005 12:10:00 4.8 0.7 6.1 3 4.7 0.7 6.1 3 211 6 212 305 0.4 0 1 0.1 05/21/2005 12:20:00 4.6 0.5 5.7 3.4 4.5 0.5 5.7 3 205 5 202 305 0.3 0.1 1 0.1 05/21/2005 12:30:00 4.9 0.6 6.1 3.4 4.9 0.6 6.1 3.4 201 4 198 305 0.3 0.1 0.8 0.1 05/21/2005 12:40:00 5.6 0.5 6.8 3.8 5.5 0.6 6.8 3.8 208 6 194 305 0.3 0 0.8 0.1 05/21/2005 12:50:00 6 0.4 6.8 4.9 5.9 0.5 7.2 4.6 214 3 215 305 0.2 0.2 0.6 0.1 05/21/2005 13:00:00 5.7 0.5 6.8 4.6 5.5 0.6 6.8 3.8 214 5 205 305 0.2 0.2 0.8 0.1 05/21/2005 13:10:00 5.2 0.5 6.8 3.4 5.1 0.6 6.8 3.4 213 5 213 305 0.4 0.2 0.8 0.1 05/21/2005 13:20:00 4.8 0.5 5.7 3.4 4.7 0.5 5.7 3 210 7 209 305 0.3 0.1 0.8 0.1 05/21/2005 13:30:00 4.9 0.6 6.5 3.8 4.9 0.6 6.5 3.4 199 6 200 305 0.3 0.1 0.8 0.1 05/21/2005 13:40:00 5.5 0.6 6.8 3.4 5.4 0.6 6.8 3.4 206 5 203 305 0.3 0.1 0.8 0.1 05/21/2005 13:50:00 5.7 0.5 6.8 4.2 5.6 0.6 6.8 3.8 209 7 203 305 0.4 0 0.8 0.3 05/21/2005 14:00:00 6 0.6 7.6 4.6 5.8 0.6 7.2 4.2 215 6 208 305 0.2 0.1 0.6 0.1 05/21/2005 14:10:00 5.8 0.5 6.8 4.2 5.7 0.7 6.8 3.8 213 5 214 305 0.2 0.1 0.6 0.1 05/21/2005 14:20:00 6.1 0.5 7.2 4.6 5.9 0.6 7.6 4.2 213 5 213 305 0.2 0.1 0.6 -0.1 05/21/2005 14:30:00 6.3 0.6 7.6 4.6 6.1 0.6 7.2 4.6 215 4 214 305 0 0.1 0.6 -0.4 05/21/2005 14:40:00 5.9 0.5 6.8 4.2 5.7 0.6 7.2 3.8 215 4 203 305 0 0.1 0.3 -0.4 05/21/2005 14:50:00 6.1 0.5 7.2 4.6 6 0.5 7.2 4.6 214 4 214 305 -0.1 0 0.3 -0.4 05/21/2005 15:00:00 6.1 0.6 7.2 4.2 6 0.6 7.2 4.6 210 6 206 305 0 0.1 0.6 -0.4 05/21/2005 15:10:00 5.6 0.6 7.2 3.4 5.5 0.6 6.8 3.4 207 6 203 305 0 0 0.6 0.1 05/21/2005 15:20:00 5.3 0.5 6.5 3.8 5.2 0.6 6.5 3 200 7 205 305 0.2 0.1 0.6 0.1 05/21/2005 15:30:00 5.3 0.7 7.2 3.4 5.2 0.8 7.2 3.4 200 6 202 305 0.2 0.1 0.6 0.1 05/21/2005 15:40:00 5.2 0.6 6.5 3.4 5.1 0.5 6.5 3.8 200 6 193 305 0.2 0.1 0.6 0.1 05/21/2005 15:50:00 5.3 0.6 6.8 3.4 5.2 0.7 6.8 3.4 200 6 210 305 0.2 0.1 0.6 0.1 05/21/2005 16:00:00 5.5 0.6 7.2 3.8 5.4 0.7 7.2 3.4 200 5 195 305 0.2 0.1 0.6 0.1 05/21/2005 16:10:00 5.2 0.5 6.5 3.8 5.1 0.6 6.1 3.4 207 7 210 305 0.1 0.1 0.6 0.1 05/21/2005 16:20:00 5 0.5 6.5 3.4 4.9 0.5 6.5 3.4 202 8 196 305 0.2 0.1 0.6 0.1 05/21/2005 16:30:00 5.2 0.5 6.5 3.4 5.2 0.5 6.1 3 205 5 203 305 0.1 0.1 0.6 -0.1 05/21/2005 16:40:00 4.6 0.6 5.7 3 4.5 0.6 5.7 3 210 6 219 305 0.1 0.1 0.6 0.1 05/21/2005 16:50:00 5 0.4 6.1 3.8 4.8 0.5 6.1 3.4 217 6 221 305 0.1 0.1 0.6 0.1 05/21/2005 17:00:00 4.8 0.4 5.7 3.8 4.6 0.5 5.7 3.4 218 5 213 305 0 0.1 0.6 -0.4 05/21/2005 17:10:00 4.6 0.4 5.7 3 4.5 0.5 5.7 3.4 202 7 201 305 0.1 0.1 0.6 -0.1 05/21/2005 17:20:00 4.3 0.4 5.3 3 4.2 0.4 5.3 3 210 6 212 305 0.1 0.1 0.6 0.1 05/21/2005 17:30:00 4.4 0.4 5.3 3 4.4 0.5 5.7 3 212 6 214 305 0.1 0.2 0.6 0.1 05/21/2005 17:40:00 4.9 0.4 6.1 3.4 4.8 0.5 6.1 3.4 211 5 208 305 0.1 0.1 0.6 -0.1 05/21/2005 17:50:00 4.9 0.5 6.5 3.4 4.9 0.5 6.5 3.4 205 6 200 305 0.2 0.2 0.6 -0.1 05/21/2005 18:00:00 5.6 0.4 6.5 4.6 5.5 0.5 6.5 4.2 205 6 198 305 0 0.1 0.6 -0.4 05/21/2005 18:10:00 5.5 0.5 6.5 4.2 5.5 0.6 6.5 3.8 201 5 198 305 -0.2 0 0.3 -0.4 05/21/2005 18:20:00 5.7 0.6 6.8 4.2 5.6 0.7 6.8 3.4 208 5 201 305 -0.1 0 0.6 -0.4 05/21/2005 18:30:00 5.6 0.5 6.8 4.2 5.6 0.6 6.8 3.8 204 5 198 305 -0.2 0.1 0.3 -0.4 05/21/2005 18:40:00 5.8 0.5 7.6 4.6 5.7 0.6 7.2 4.2 208 5 211 305 -0.3 0.1 0.3 -0.4 05/21/2005 18:50:00 6 0.6 8 4.2 5.7 0.8 8 3.8 217 6 216 305 -0.2 0 0.3 -0.4 05/21/2005 19:00:00 5.3 0.7 6.8 3.4 5 0.7 6.5 3.4 216 6 218 305 -0.2 0 0.3 -0.4 05/21/2005 19:10:00 5 0.5 6.1 3.8 4.9 0.7 6.5 3 206 7 204 305 0 0 0.6 -0.4 05/21/2005 19:20:00 5.6 0.6 6.8 3.8 5.4 0.7 6.8 3.8 209 5 207 305 -0.1 0 0.3 -0.4 05/21/2005 19:30:00 5.3 0.6 6.8 3.4 5 0.7 7.2 3 210 6 213 305 -0.3 0 0.3 -0.4 05/21/2005 19:40:00 5.2 0.5 6.1 3.8 5 0.5 6.1 3.4 213 6 217 305 -0.1 0 0.3 -0.4 05/21/2005 19:50:00 5.7 0.5 6.8 4.2 5.5 0.6 6.5 3.8 208 6 200 305 -0.3 0.1 0.3 -0.4 05/21/2005 20:00:00 5.6 0.6 6.8 3.8 5.3 0.6 6.5 3.4 214 8 218 305 -0.3 0.1 0.3 -0.4 05/21/2005 20:10:00 5.9 0.6 7.2 4.2 5.6 0.6 7.6 3.8 208 7 217 305 -0.4 0.1 0.1 -0.6 05/21/2005 20:20:00 5.6 0.7 7.2 3.8 5.5 0.8 7.2 3.4 214 5 217 305 -0.5 0 0.1 -0.6 05/21/2005 20:30:00 5.9 0.5 7.2 4.9 5.7 0.6 7.2 4.2 212 5 206 305 -0.6 0 -0.4 -0.6 05/21/2005 20:40:00 5.9 0.5 7.2 4.6 5.7 0.6 6.8 3.8 216 6 215 305 -0.6 0 -0.1 -0.8 05/21/2005 20:50:00 6.1 0.6 7.2 4.6 5.9 0.7 7.2 3.8 214 7 221 305 -0.8 0.1 -0.1 -1.1 05/21/2005 21:00:00 5.8 0.5 7.2 4.6 5.7 0.5 6.8 4.6 212 6 214 305 -0.7 0 -0.4 -1.1 05/21/2005 21:10:00 6.3 0.5 7.6 4.9 6.3 0.5 7.2 4.6 203 5 202 305 -1 0.1 -0.4 -1.1 05/21/2005 21:20:00 6.1 0.4 7.2 4.9 6.1 0.5 7.2 4.6 204 5 204 305 -1.1 0 -0.6 -1.3 05/21/2005 21:30:00 6 0.5 7.2 4.2 6 0.5 6.8 4.2 205 4 202 305 -1.1 0.1 -0.6 -1.1 05/21/2005 21:40:00 6 0.5 7.2 4.2 5.9 0.6 7.2 4.2 201 6 209 305 -1 0.1 -0.4 -1.1 05/21/2005 21:50:00 6.1 0.4 6.8 4.9 5.9 0.5 7.2 4.6 201 5 197 305 -1 0.1 -0.4 -1.1 05/21/2005 22:00:00 6 0.4 6.8 4.9 6 0.4 7.2 4.9 198 4 200 305 -1 0.1 -0.4 -1.1 05/21/2005 22:10:00 6.2 0.4 7.2 4.9 6.2 0.5 7.2 4.9 198 4 194 305 -0.8 0 -0.4 -1.1 05/21/2005 22:20:00 6.3 0.5 7.6 5.3 6.3 0.5 7.2 5.3 198 4 202 305 -0.8 0 -0.4 -1.1 05/21/2005 22:30:00 6 0.4 6.8 4.9 6 0.5 7.2 4.2 197 4 199 305 -0.9 0.1 -0.4 -1.1 05/21/2005 22:40:00 6.3 0.4 7.2 4.9 6.2 0.6 7.2 4.2 196 4 196 305 -1 0.1 -0.4 -1.1 05/21/2005 22:50:00 6.1 0.4 6.8 5.3 6 0.4 7.2 4.6 195 4 194 305 -1 0.1 -0.4 -1.1 05/21/2005 23:00:00 5.7 0.6 7.6 4.2 5.6 0.7 7.2 3.8 191 5 196 305 -1 0.1 -0.4 -1.1 05/21/2005 23:10:00 6 0.5 7.2 4.6 6 0.5 7.2 4.2 192 5 188 305 -1 0.1 -0.4 -1.1 05/21/2005 23:20:00 5.9 0.5 7.2 4.2 5.7 0.7 6.8 3.8 201 7 208 305 -0.9 0 -0.4 -1.1 05/21/2005 23:30:00 6.1 0.5 7.6 4.9 5.9 0.6 7.6 4.2 205 5 208 305 -0.8 0.1 -0.4 -1.1 05/21/2005 23:40:00 5.6 0.6 6.8 3.8 5.4 0.6 6.8 3.4 199 8 189 305 -0.9 0 -0.4 -1.1 05/21/2005 23:50:00 5.3 0.6 6.8 3.8 5.3 0.6 6.8 3.8 201 5 198 305 -0.9 0.1 -0.4 -1.1 05/22/2005 00:00:00 5.3 0.5 6.8 3.8 5.2 0.6 6.5 3 213 4 214 305 -0.9 0.1 -0.4 -1.1 05/22/2005 00:10:00 5.4 0.5 6.5 3.8 5.3 0.6 6.8 3.8 214 0 214 305 -1.1 0.1 -0.4 -1.3 05/22/2005 00:20:00 4.8 0.6 6.1 3 4.8 0.6 6.1 2.6 214 0 214 305 -1.1 0.1 -0.6 -1.3 05/22/2005 00:30:00 4.6 0.5 5.7 2.6 4.4 0.7 5.7 2.3 214 0 214 305 -1.1 0.1 -0.6 -1.1 05/22/2005 00:40:00 5.5 0.6 6.8 4.2 5.3 0.7 6.8 3.4 214 0 214 305 -1.2 0.2 -0.6 -1.5 05/22/2005 00:50:00 5.7 0.4 6.8 4.6 5.6 0.5 6.5 4.2 214 0 214 305 -1.5 0.1 -1.1 -1.8 05/22/2005 01:00:00 5.9 0.5 7.2 4.6 5.7 0.5 7.6 4.2 214 0 214 305 -1.5 0.2 -0.8 -1.8 05/22/2005 01:10:00 5.8 0.4 6.5 4.6 5.8 0.6 6.8 3.8 214 0 214 305 -1.6 0.1 -1.1 -1.8 05/22/2005 01:20:00 5.6 0.4 6.5 4.2 5.5 0.5 6.5 4.2 214 0 214 305 -1.6 0 -1.1 -1.8 05/22/2005 01:30:00 5.6 0.6 7.2 3.8 5.5 0.6 6.8 3.4 214 0 214 305 -1.6 0 -1.1 -1.8 05/22/2005 01:40:00 5.7 0.5 6.5 4.2 5.5 0.6 6.8 3.4 214 0 214 305 -1.8 0 -1.5 -2 05/22/2005 01:50:00 6.3 0.4 7.6 4.9 6.2 0.6 7.6 4.2 214 0 214 305 -2 0.2 -1.3 -2.2 05/22/2005 02:00:00 5.9 0.4 6.8 4.6 5.9 0.5 6.8 4.6 214 0 214 305 -2.2 0.1 -1.8 -2.4 05/22/2005 02:10:00 5.5 0.3 6.5 4.6 5.6 0.4 6.5 4.2 214 0 214 305 -2.3 0 -1.8 -2.4 05/22/2005 02:20:00 5.3 0.4 6.1 4.2 5.3 0.5 6.5 3.8 214 0 214 305 -2.3 0 -2.2 -2.4 05/22/2005 02:30:00 5.3 0.4 6.1 4.2 5.4 0.4 6.5 4.2 214 0 214 305 -2.3 0 -1.8 -2.4 05/22/2005 02:40:00 5.5 0.3 6.5 4.2 5.5 0.5 6.5 3.8 214 0 214 305 -2.4 0 -2 -2.7 05/22/2005 02:50:00 5.1 0.5 6.1 3.4 5 0.5 6.1 3.4 214 0 214 305 -2.3 0 -2.2 -2.4 05/22/2005 03:00:00 5.3 0.5 6.8 4.2 5.2 0.5 6.1 3.8 214 0 214 305 -2.2 0 -2 -2.4 05/22/2005 03:10:00 5.7 0.4 6.5 4.6 5.5 0.5 6.5 3.8 214 0 214 305 -2.2 0 -2 -2.2 05/22/2005 03:20:00 4.5 0.6 6.1 3 4.3 0.7 5.7 2.3 214 0 214 305 -2.2 0 -2 -2.2 05/22/2005 03:30:00 4.5 0.3 5.7 3.4 4.3 0.5 5.7 3 214 0 214 305 -2 0 -1.8 -2.2 05/22/2005 03:40:00 4.4 0.3 5.3 3.4 4.3 0.4 5.3 3 214 0 214 305 -1.9 0 -1.8 -2 05/22/2005 03:50:00 4.2 0.3 5.3 3.4 4.2 0.4 5.3 3.4 214 0 214 305 -1.8 0 -1.8 -2 05/22/2005 04:00:00 4.4 0.4 5.7 3.8 4.4 0.5 5.7 3 214 0 214 305 -1.6 0 -1.1 -1.8 05/22/2005 04:10:00 4.2 0.4 5.3 3 4.2 0.4 5.3 3.4 214 0 214 305 -1.6 0 -1.3 -1.8 05/22/2005 04:20:00 4.1 0.5 5.3 3 4.1 0.6 5.3 2.6 214 0 214 305 -1.5 0 -1.3 -1.8 05/22/2005 04:30:00 4.5 0.4 5.7 3.4 4.6 0.5 5.7 3 214 0 214 305 -1.5 0 -1.3 -1.8 05/22/2005 04:40:00 4 0.4 4.9 3 4 0.4 4.9 3 214 0 214 305 -1.5 0 -1.3 -1.8 05/22/2005 04:50:00 3.5 0.5 4.6 1.9 3.6 0.5 4.6 2.3 214 0 214 305 -1.5 0 -1.1 -1.5 05/22/2005 05:00:00 4.1 0.5 5.3 3 4.2 0.6 5.7 2.6 214 0 214 305 -1.4 0 -1.3 -1.5 05/22/2005 05:10:00 4.1 0.4 4.9 3 4.2 0.4 5.3 3 214 0 214 305 -1.4 0 -1.3 -1.5 05/22/2005 05:20:00 4.2 0.3 4.9 3.4 4.4 0.3 4.9 3.4 214 0 214 305 -1.3 0 -1.1 -1.3 05/22/2005 05:30:00 3.8 0.5 5.3 2.6 3.9 0.6 4.9 2.3 214 0 214 305 -1.2 0 -1.1 -1.3 05/22/2005 05:40:00 3.7 0.4 4.9 2.6 3.8 0.4 4.9 2.6 214 0 214 305 -1.1 0 -1.1 -1.3 05/22/2005 05:50:00 3.3 0.4 4.2 2.3 3.3 0.4 4.6 2.3 214 0 214 305 -1.1 0 -0.8 -1.1 05/22/2005 06:00:00 3.2 0.5 4.2 2.3 3.1 0.4 4.2 2.3 214 0 214 305 -1 0 -0.8 -1.1 05/22/2005 06:10:00 3 0.3 3.8 2.3 2.9 0.3 3.8 1.9 214 0 214 305 -0.9 0 -0.6 -1.1 05/22/2005 06:20:00 3.2 0.3 3.8 2.3 3.1 0.4 4.2 2.3 214 0 214 305 -0.7 0 -0.6 -0.8 05/22/2005 06:30:00 3.2 0.3 3.8 1.9 3.2 0.3 3.8 2.3 214 0 214 305 -0.7 0 -0.6 -0.8 05/22/2005 06:40:00 3.3 0.3 4.2 2.6 3.3 0.4 4.2 1.9 214 0 214 305 -0.5 0 -0.4 -0.6 05/22/2005 06:50:00 3.8 0.5 4.9 3 3.8 0.5 4.9 2.6 214 0 214 305 -0.4 0 0.1 -0.6 05/22/2005 07:00:00 3.9 0.5 4.9 2.6 3.9 0.5 4.9 2.3 214 0 214 305 -0.3 0 0.1 -0.4 05/22/2005 07:10:00 4.3 0.5 5.3 2.3 4.3 0.5 5.3 2.6 214 0 214 305 -0.3 0 0.1 -0.4 05/22/2005 07:20:00 4.3 0.4 5.3 3 4.4 0.4 5.7 3 214 0 214 305 -0.3 0 0.3 -0.4 05/22/2005 07:30:00 4 0.5 5.3 2.6 4.1 0.5 5.3 2.3 214 0 214 305 -0.3 0 0.1 -0.4 05/22/2005 07:40:00 4 0.5 5.3 2.6 4 0.5 5.3 2.3 214 0 214 305 -0.2 0 0.1 -0.4 05/22/2005 07:50:00 3.9 0.4 4.9 2.6 3.8 0.5 5.3 2.6 214 0 214 305 -0.2 0 0.1 -0.4 05/22/2005 08:00:00 4.2 0.4 5.3 3 4.1 0.4 5.3 2.6 214 1 214 305 -0.2 0 0.1 -0.4 05/22/2005 08:10:00 4.1 0.5 4.9 2.6 4 0.5 4.9 2.6 214 0 214 305 -0.1 0 0.3 -0.4 05/22/2005 08:20:00 4.3 0.4 5.3 3 4 0.5 5.3 2.3 214 0 214 305 0 0 0.6 0.1 05/22/2005 08:30:00 4.6 0.5 6.1 3 4.5 0.6 5.7 2.3 214 0 214 305 0.2 0.1 0.6 0.1 05/22/2005 08:40:00 4.6 0.4 5.7 3.8 4.4 0.4 5.3 3.4 214 0 214 305 0.1 0.1 0.6 0.1 05/22/2005 08:50:00 4.1 0.4 5.3 3 3.9 0.4 4.9 2.6 214 0 214 305 0.3 0.1 1 0.1 05/22/2005 09:00:00 4.1 0.5 4.9 2.6 4.1 0.6 5.7 2.6 199 8 213 305 0.7 0 1 0.6 05/22/2005 09:10:00 4.1 0.3 4.9 3.4 4.2 0.4 5.3 3 195 5 195 305 1 0.1 1.3 0.8 05/22/2005 09:20:00 4.1 0.4 5.3 3 4 0.4 4.9 3 200 5 200 305 1.4 0 2 1.3 05/22/2005 09:30:00 4 0.5 5.3 2.3 4 0.5 5.3 2.6 195 8 203 305 1.4 0 2 1.3 05/22/2005 09:40:00 4.1 0.6 5.7 2.6 4.3 0.4 4.9 2.6 192 10 208 305 1.4 0.1 2 1.3 05/22/2005 09:50:00 4.4 0.3 5.3 3 4.3 0.4 5.3 3 205 5 208 305 1.1 0.1 1.5 1 05/22/2005 10:00:00 4 0.3 4.6 2.6 3.9 0.4 4.6 2.6 206 4 203 305 1.2 0.1 1.5 1 05/22/2005 10:10:00 3.7 0.4 4.6 2.3 3.6 0.5 4.6 2.3 204 5 208 305 1.1 0 1.5 1 05/22/2005 10:20:00 3.8 0.4 4.6 1.9 3.6 0.5 4.6 2.3 200 5 193 305 1.2 0.1 2 1 05/22/2005 10:30:00 3.8 0.4 4.9 2.3 3.8 0.5 5.3 2.6 193 6 197 305 1.6 0.1 2.2 1.5 05/22/2005 10:40:00 4.2 0.5 5.3 2.3 4.2 0.5 5.3 2.6 192 5 188 305 1.6 0.1 2.2 1.5 05/22/2005 10:50:00 3.9 0.7 5.7 2.3 4.2 0.6 6.1 2.3 187 7 183 305 1.7 0.1 2.5 1.5 05/22/2005 11:00:00 4 0.7 5.3 1.9 4.2 0.6 5.3 2.6 187 8 191 305 2 0 2.5 2 05/22/2005 11:10:00 4 0.6 5.7 2.3 4.7 0.6 6.1 2.6 181 6 188 305 2.2 0.1 2.7 2 05/22/2005 11:20:00 3.8 0.7 5.3 2.3 4.4 0.6 6.1 2.6 182 9 186 305 2.3 0.1 2.9 2.2 05/22/2005 11:30:00 4.5 0.5 5.7 2.6 4.6 0.5 5.7 3 190 6 191 305 2.2 0 2.7 2 05/22/2005 11:40:00 3.7 0.7 5.3 2.3 4.4 0.7 6.5 2.6 180 11 185 305 2.3 0.2 3.2 2 05/22/2005 11:50:00 3.3 0.6 4.9 1.9 4.1 0.5 6.1 2.6 179 8 186 305 2.6 0.2 3.2 2.2 05/22/2005 12:00:00 3.8 0.7 5.3 1.9 4.2 0.5 5.3 3 184 8 179 305 2.4 0.1 3.2 2.2 05/22/2005 12:10:00 4.1 0.3 4.9 2.6 4.2 0.4 4.9 3 189 3 192 305 2.3 0.1 2.9 2.2 05/22/2005 12:20:00 4.1 0.3 4.6 3 4.1 0.3 4.9 3 194 3 194 305 2.5 0.1 2.9 2.2 05/22/2005 12:30:00 4 0.3 4.6 3.4 4.1 0.3 4.9 3.4 198 3 197 305 2.5 0.2 2.9 2.2 05/22/2005 12:40:00 4 0.4 4.9 3 4.1 0.4 5.3 3 195 4 195 305 2.5 0.1 2.9 2.2 05/22/2005 12:50:00 4.1 0.4 4.9 3.4 4.2 0.4 5.3 3 191 3 194 305 2.5 0 2.9 2.2 05/22/2005 13:00:00 4 0.3 4.6 3 4 0.4 4.9 3 194 4 190 305 2.7 0 3.2 2.5 05/22/2005 13:10:00 4 0.2 4.6 3.4 4 0.3 4.9 3 192 3 195 305 2.7 0 3.2 2.5 05/22/2005 13:20:00 3.5 0.3 4.2 2.6 3.4 0.4 4.2 2.3 197 5 193 305 2.9 0.2 3.7 2.7 05/22/2005 13:30:00 3.7 0.4 4.6 2.6 3.7 0.4 4.9 2.6 194 6 186 305 2.9 0.2 3.4 2.7 05/22/2005 13:40:00 3.6 0.4 4.6 2.6 3.7 0.5 4.6 2.3 195 6 192 305 2.9 0.2 3.4 2.7 05/22/2005 13:50:00 3.8 0.4 4.6 2.6 3.8 0.4 4.9 2.6 194 5 198 305 3 0.1 3.4 2.9 05/22/2005 14:00:00 3.6 0.4 4.6 2.6 3.6 0.5 4.6 2.3 197 5 201 305 2.9 0.1 3.4 2.7 05/22/2005 14:10:00 3.6 0.5 4.9 2.3 3.5 0.6 4.9 2.3 200 5 205 305 3.3 0.1 3.7 2.9 05/22/2005 14:20:00 3.7 0.4 4.6 2.3 3.6 0.5 4.9 2.6 197 6 197 305 3.2 0 3.7 2.9 05/22/2005 14:30:00 3.9 0.5 5.3 2.6 3.9 0.5 5.3 2.6 195 5 190 305 3.2 0 3.4 2.9 05/22/2005 14:40:00 3.6 0.4 4.6 1.9 3.7 0.5 4.6 2.3 193 5 196 305 3.2 0 3.7 2.9 05/22/2005 14:50:00 3.9 0.5 4.9 2.6 4 0.4 5.3 2.6 194 7 197 305 3.3 0.1 3.7 2.9 05/22/2005 15:00:00 3.8 0.5 5.3 2.6 3.8 0.5 5.3 2.3 201 7 192 305 3.2 0 3.4 2.9 05/22/2005 15:10:00 3.4 0.4 4.6 2.6 3.3 0.5 4.6 2.3 202 5 204 305 3.1 0 3.7 2.9 05/22/2005 15:20:00 2.9 0.3 3.8 1.9 2.9 0.4 3.8 1.9 202 5 217 305 3.3 0.1 3.7 3.2 05/22/2005 15:30:00 2.9 0.5 4.2 1.5 3 0.4 4.6 1.9 196 7 194 305 3.4 0.1 3.7 3.2 05/22/2005 15:40:00 2.7 0.4 3.8 1.5 2.9 0.4 3.8 1.9 193 9 192 305 3.6 0 3.7 3.4 05/22/2005 15:50:00 2.9 0.5 4.6 1.9 3.1 0.4 4.6 1.9 192 6 197 305 3.5 0 3.7 3.2 05/22/2005 16:00:00 2.6 0.6 4.2 1.1 3.3 0.6 4.9 1.9 180 12 177 305 3.6 0.1 3.9 3.2 05/22/2005 16:10:00 3 0.4 3.8 1.5 3.2 0.4 4.2 2.3 194 6 188 305 3.6 0 3.9 3.4 05/22/2005 16:20:00 3.1 0.5 4.2 1.5 3.1 0.5 4.2 1.9 199 6 200 305 3.7 0 3.9 3.4 05/22/2005 16:30:00 3.8 0.6 5.3 2.6 3.8 0.6 4.9 2.3 202 5 198 305 3.5 0.1 3.9 3.4 05/22/2005 16:40:00 3.5 0.5 4.6 2.3 3.6 0.5 4.9 2.6 202 4 202 305 3.6 0 3.7 3.4 05/22/2005 16:50:00 3 0.5 4.2 1.9 3.1 0.5 4.2 1.9 195 8 192 305 3.9 0.1 4.2 3.4 05/22/2005 17:00:00 3.1 0.7 4.6 1.5 3.3 0.6 4.9 1.5 190 8 193 305 3.7 0 3.9 3.4 05/22/2005 17:10:00 2.9 0.6 4.2 1.1 3.4 0.5 4.9 2.3 184 10 181 305 3.7 0 4.2 3.4 05/22/2005 17:20:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 216 8 219 305 3.6 0.2 4.2 3.2 05/22/2005 17:30:00 3.1 0.5 4.2 1.9 3.1 0.5 4.2 1.9 208 5 201 305 3.3 0 3.4 2.9 05/22/2005 17:40:00 3 0.5 3.8 1.9 2.9 0.4 3.8 1.9 204 8 200 305 3.3 0 3.4 3.2 05/22/2005 17:50:00 2.9 0.6 3.8 1.5 2.9 0.5 3.8 1.5 203 7 208 305 3.4 0 3.4 3.2 05/22/2005 18:00:00 3.4 1.1 6.1 1.1 3.3 1 5.7 1.5 208 10 200 305 3.2 0 3.4 2.9 05/22/2005 18:10:00 4.5 0.4 5.3 3 4.3 0.5 5.3 3 199 6 197 305 3.2 0.1 3.4 2.9 05/22/2005 18:20:00 4 0.3 4.9 2.6 4.1 0.4 4.9 2.6 193 6 192 305 3.1 0 3.4 2.9 05/22/2005 18:30:00 3.8 0.4 4.9 2.6 3.8 0.5 4.9 2.6 195 9 193 305 3.1 0 3.4 2.9 05/22/2005 18:40:00 4 0.5 4.9 2.3 3.9 0.5 5.3 2.6 202 6 199 305 2.7 0 3.2 2.5 05/22/2005 18:50:00 3.6 0.4 4.6 2.3 3.8 0.4 4.6 2.6 192 7 204 305 2.8 0.1 3.2 2.5 05/22/2005 19:00:00 3.5 0.5 4.9 2.3 3.6 0.5 4.6 2.3 198 7 202 305 2.8 0.1 3.2 2.5 05/22/2005 19:10:00 3.6 0.5 4.6 1.9 3.8 0.5 5.3 2.6 189 7 198 305 2.8 0.1 3.2 2.7 05/22/2005 19:20:00 3.8 0.4 4.9 2.6 3.9 0.4 4.9 2.6 192 6 194 305 2.8 0.1 3.2 2.7 05/22/2005 19:30:00 3.5 0.4 4.6 2.6 3.5 0.5 4.6 2.3 194 4 197 305 2.7 0 3.2 2.5 05/22/2005 19:40:00 3.2 0.4 4.2 2.3 3.4 0.4 4.6 2.6 189 4 189 305 2.6 0 3.2 2.5 05/22/2005 19:50:00 3.2 0.8 4.9 1.1 3.5 0.6 4.9 1.9 185 5 188 305 2.6 0.1 3.2 2.5 05/22/2005 20:00:00 2.7 0.6 4.2 1.5 3.4 0.6 4.9 2.3 180 9 184 305 2.8 0.2 3.4 2.5 05/22/2005 20:10:00 2.8 0.4 3.8 1.1 2.9 0.4 3.8 1.9 196 9 182 305 2.5 0.3 3.4 2.2 05/22/2005 20:20:00 3.1 0.5 4.2 1.9 3.3 0.4 4.2 2.3 198 7 203 305 2.3 0.1 2.7 2.2 05/22/2005 20:30:00 2 0.6 3.4 0.7 2.5 0.7 3.4 0.7 175 13 188 305 2.3 0.1 2.7 2.2 05/22/2005 20:40:00 2.3 0.5 4.2 1.1 3.1 0.5 4.2 1.9 167 9 187 305 2.5 0.2 3.2 2.2 05/22/2005 20:50:00 2.6 0.7 4.2 1.1 2.9 0.5 4.2 1.9 149 9 148 305 2.8 0.1 3.2 2.7 05/22/2005 21:00:00 3.2 0.5 4.6 1.9 3.4 0.4 4.6 2.3 147 10 137 305 2.6 0 2.9 2.5 05/22/2005 21:10:00 3.6 0.3 4.6 2.6 3.7 0.3 4.6 2.6 137 5 140 305 2.5 0 2.9 2.5 05/22/2005 21:20:00 4 0.4 4.9 2.6 4 0.4 4.9 3 131 6 130 305 2.5 0 2.9 2.2 05/22/2005 21:30:00 3.7 0.4 4.9 2.6 3.8 0.5 4.9 2.6 130 7 131 305 2.7 0.1 3.2 2.5 05/22/2005 21:40:00 4.5 0.5 5.7 3.4 4.6 0.5 5.7 3.8 133 5 132 305 2.7 0.1 3.2 2.5 05/22/2005 21:50:00 5.2 0.5 6.1 3.4 5.2 0.5 6.5 3.4 128 5 131 305 2.3 0.2 2.9 2.2 05/22/2005 22:00:00 5.3 0.3 6.1 4.6 5.4 0.4 6.1 4.6 131 3 137 305 2 0 2.5 2 05/22/2005 22:10:00 4.8 0.4 5.7 3.4 4.9 0.4 5.7 3.8 131 4 138 305 2 0 2.5 2 05/22/2005 22:20:00 4.7 0.4 5.7 3.8 4.7 0.4 5.7 3.8 129 6 117 305 2 0.1 2.5 2 05/22/2005 22:30:00 4.5 0.4 5.3 3 4.6 0.4 5.3 3.4 128 6 128 305 1.9 0.2 2.5 1.7 05/22/2005 22:40:00 4 0.5 5.7 3 4.2 0.4 5.7 3.4 124 6 136 305 1.9 0.1 2.5 1.7 05/22/2005 22:50:00 5.1 0.4 5.7 3.8 5.1 0.4 6.1 4.2 133 4 136 305 1.8 0.1 2.5 1.5 05/22/2005 23:00:00 5.6 0.3 6.5 4.2 5.5 0.4 6.5 4.2 133 3 136 305 1.6 0 2 1.5 05/22/2005 23:10:00 5 0.5 6.1 3.8 5 0.5 6.1 3.8 127 6 133 305 1.6 0 2 1.5 05/22/2005 23:20:00 4.8 0.5 6.1 3 4.9 0.5 6.1 3.4 122 8 124 305 1.6 0 2 1.5 05/22/2005 23:30:00 5.2 0.5 6.5 3.4 5.2 0.5 6.5 3.8 122 6 127 305 1.7 0.1 2.2 1.5 05/22/2005 23:40:00 5.4 0.6 6.5 3.4 5.4 0.6 6.5 3.4 125 6 129 305 1.7 0.1 2.2 1.5 05/22/2005 23:50:00 5.3 0.5 6.5 4.2 5.3 0.5 6.8 3.8 132 6 140 305 1.7 0 2.2 1.5 05/23/2005 00:00:00 5.8 0.3 6.5 4.6 5.7 0.4 6.5 4.2 135 4 131 305 1.4 0 2 1.3 05/23/2005 00:10:00 6.1 0.4 6.8 4.2 6 0.4 6.8 4.6 135 3 135 305 1.3 0 1.5 1.3 05/23/2005 00:20:00 6.2 0.3 6.8 5.3 6 0.3 6.8 4.9 137 3 139 305 1.2 0 1.5 1 05/23/2005 00:30:00 5.2 0.5 6.5 3.8 5.2 0.5 6.1 3.8 119 9 119 305 1.3 0 1.7 1 05/23/2005 00:40:00 5.1 0.4 6.1 4.2 5 0.4 6.1 3.8 115 5 122 305 1.4 0 2 1.3 05/23/2005 00:50:00 5.8 0.5 6.8 4.6 5.8 0.5 6.8 4.2 121 6 118 305 1.4 0 2 1.3 05/23/2005 01:00:00 5.4 0.6 7.2 3.8 5.5 0.6 6.8 4.2 124 8 134 305 1.3 0.1 2 1.3 05/23/2005 01:10:00 6.9 0.7 8.4 4.9 6.8 0.7 8.4 4.9 132 5 131 305 1.2 0.1 1.7 1 05/23/2005 01:20:00 6.7 0.5 7.6 5.3 6.6 0.5 7.6 4.9 131 5 124 305 1.1 0.1 1.5 1 05/23/2005 01:30:00 7.3 0.6 8.8 5.3 7.2 0.6 8.4 5.3 134 5 132 305 1.1 0.1 1.5 1 05/23/2005 01:40:00 7.8 0.4 8.4 6.1 7.6 0.4 8.4 6.5 134 3 131 305 1.2 0.1 1.5 1 05/23/2005 01:50:00 7.6 0.5 8.8 6.1 7.4 0.5 8.4 6.1 137 3 140 305 1.1 0 1.5 1 05/23/2005 02:00:00 7.5 0.4 8.4 6.5 7.3 0.4 8.4 6.1 134 3 137 305 1.2 0.2 1.5 1 05/23/2005 02:10:00 7.6 0.4 8.8 6.1 7.5 0.5 8.8 6.1 134 3 133 305 1.2 0.1 1.5 1 05/23/2005 02:20:00 7.6 0.4 8.8 5.7 7.5 0.4 8.4 5.7 132 3 134 305 1.2 0.1 1.5 1 05/23/2005 02:30:00 7.8 0.5 9.1 5.3 7.7 0.5 8.8 5.7 133 3 135 305 1.2 0.1 1.5 1 05/23/2005 02:40:00 7.5 0.6 9.1 5.7 7.4 0.6 8.8 5.3 130 5 130 305 1.2 0.1 1.7 1 05/23/2005 02:50:00 7.6 0.7 9.5 5.7 7.5 0.6 9.5 5.3 128 6 118 305 1.2 0.1 1.7 1 05/23/2005 03:00:00 7.7 1 9.9 4.2 7.7 1 9.9 4.6 131 6 129 305 1.2 0 1.5 1.3 05/23/2005 03:10:00 8.3 0.7 10.3 6.1 8.1 0.7 10.3 6.1 130 6 143 305 1.4 0 2 1.3 05/23/2005 03:20:00 8.3 0.8 9.9 5.7 8.2 0.8 9.9 5.7 130 6 130 305 1.4 0 2 1.3 05/23/2005 03:30:00 8.2 1 10.7 5.3 8.1 1 10.3 5.3 129 8 146 305 1.4 0.1 2 1.3 05/23/2005 03:40:00 8 1 11.1 4.9 7.8 1 11.1 5.7 132 8 137 305 1.3 0.1 2 1.3 05/23/2005 03:50:00 7.7 1 10.3 5.3 7.6 1 9.9 4.6 131 10 148 305 1.3 0.1 1.7 1 05/23/2005 04:00:00 7.8 1 10.7 4.9 7.7 1 11.1 5.3 132 9 127 305 1.2 0 1.7 1.3 05/23/2005 04:10:00 7.8 1.3 11.1 4.6 7.6 1.3 10.3 4.6 132 10 137 305 1.2 0.1 2 1 05/23/2005 04:20:00 7.3 0.8 9.5 4.6 7.1 0.8 9.9 4.9 138 6 140 305 1.2 0.1 1.5 1 05/23/2005 04:30:00 6.9 0.7 8.8 4.2 6.8 0.7 8.4 4.2 138 6 143 305 1 0 1.5 0.8 05/23/2005 04:40:00 7 0.6 8.4 5.3 6.8 0.6 8.4 5.3 136 5 142 305 0.9 0 1.3 0.8 05/23/2005 04:50:00 6.8 0.5 8 5.3 6.6 0.5 8 5.3 139 5 143 305 0.8 0 1.3 0.6 05/23/2005 05:00:00 7.4 0.6 9.1 5.7 7.2 0.5 8.8 5.7 137 4 141 305 0.8 0 1.3 0.6 05/23/2005 05:10:00 7.9 0.5 9.1 6.1 7.7 0.5 8.8 6.1 133 4 132 305 0.9 0 1.3 0.8 05/23/2005 05:20:00 8 0.7 9.5 6.1 7.8 0.6 9.5 6.1 131 4 124 305 0.9 0 1.5 0.8 05/23/2005 05:30:00 8 0.7 9.9 6.1 7.9 0.6 9.1 6.1 134 5 135 305 0.8 0 1.3 0.8 05/23/2005 05:40:00 9 0.7 10.7 6.8 8.8 0.7 10.7 6.8 131 4 133 305 0.8 0 1 0.6 05/23/2005 05:50:00 8.9 0.8 10.3 6.5 8.8 0.8 10.3 6.5 133 5 138 305 0.8 0 1 0.6 05/23/2005 06:00:00 8.5 0.7 9.9 6.1 8.4 0.8 9.9 6.5 133 4 133 305 0.8 0 1 0.8 05/23/2005 06:10:00 8 0.7 9.5 6.1 7.8 0.7 9.1 4.9 132 5 128 305 0.9 0 1.3 0.8 05/23/2005 06:20:00 7.8 1 9.5 4.9 7.7 0.8 9.5 4.9 126 10 142 305 1.1 0.1 1.5 0.8 05/23/2005 06:30:00 6.8 1.1 10.3 4.2 6.8 1 9.5 4.2 123 12 105 305 1.1 0 1.5 1 05/23/2005 06:40:00 7.4 1.3 10.3 4.6 7.4 1.3 10.3 4.6 127 11 127 305 1.2 0.1 1.5 1 05/23/2005 06:50:00 7.5 0.9 9.9 5.3 7.4 0.8 9.5 5.3 135 7 133 305 1 0 1.5 0.8 05/23/2005 07:00:00 7.3 0.7 9.1 5.3 7.1 0.7 9.5 4.9 134 6 129 305 0.8 0 1.3 0.6 05/23/2005 07:10:00 8.3 1 11.5 6.1 8.1 1.1 11.1 4.6 133 7 133 305 0.8 0 1 0.6 05/23/2005 07:20:00 8.5 1.2 12.2 5.3 8.4 1.2 11.1 5.7 122 12 124 305 0.7 0.1 1 0.6 05/23/2005 07:30:00 10.6 1.3 13.7 6.8 10.4 1.2 13.3 6.8 117 8 118 305 0.5 0 1 0.6 05/23/2005 07:40:00 10.5 1.2 13.7 6.8 10.3 1.2 13.7 7.2 118 8 118 305 0.6 0.1 1 0.6 05/23/2005 07:50:00 10.9 1 13 8 10.7 1 13.3 7.6 119 6 121 305 0.6 0 1 0.6 05/23/2005 08:00:00 10.5 1 13 6.8 10.3 1 12.6 6.8 119 6 124 305 0.6 0 1 0.6 05/23/2005 08:10:00 10 1.2 13 6.8 9.9 1.2 13 6.8 124 10 112 305 0.6 0 1 0.6 05/23/2005 08:20:00 10.6 0.8 12.6 7.6 10.5 0.8 12.6 8 131 5 140 305 0.6 0 1 0.6 05/23/2005 08:30:00 10.8 0.9 13 8.4 10.6 0.9 13 7.6 129 5 138 305 0.6 0 0.8 0.6 05/23/2005 08:40:00 9.8 1.2 12.2 6.5 9.8 1.1 13 6.5 128 10 125 305 0.6 0 0.8 0.6 05/23/2005 08:50:00 9.1 1.2 14.1 6.1 9.1 1.3 14.5 6.1 122 11 118 305 0.7 0 0.8 0.6 05/23/2005 09:00:00 9.1 1.1 12.6 6.5 9.1 1.1 13.7 6.1 125 10 122 305 0.7 0 1 0.6 05/23/2005 09:10:00 10.7 1.2 13 6.8 10.6 1.2 13 5.3 129 7 131 305 0.7 0 1.3 0.6 05/23/2005 09:20:00 10.5 1 13.3 8 10.4 1 13.7 7.6 130 6 141 305 0.6 0 1.3 0.6 05/23/2005 09:30:00 10.3 0.8 13 8 10.1 0.9 12.6 7.2 131 6 136 305 0.7 0 1.3 0.6 05/23/2005 09:40:00 9.9 0.8 11.8 7.2 9.8 0.8 11.8 6.8 130 6 133 305 0.9 0 1.5 0.8 05/23/2005 09:50:00 9.6 0.9 11.5 7.6 9.5 0.9 11.8 7.6 130 6 131 305 1 0 1.5 0.8 05/23/2005 10:00:00 9.4 1 11.8 6.5 9.4 1 12.2 6.5 130 8 130 305 1 0.1 1.5 0.8 05/23/2005 10:10:00 10 1.3 12.6 6.5 9.8 1.3 12.6 5.7 130 7 131 305 1.2 0.1 1.5 1 05/23/2005 10:20:00 11.1 0.8 13 8.4 10.9 0.9 12.6 8 130 5 133 305 1.4 0 2 1.3 05/23/2005 10:30:00 10.1 1.2 13 6.5 10.1 1.2 13.7 6.8 128 8 130 305 1.5 0 2 1.3 05/23/2005 10:40:00 9.6 1.2 13.7 6.1 9.6 1.2 14.5 6.1 120 10 111 305 1.4 0 2 1.3 05/23/2005 10:50:00 8.5 1.5 12.2 5.3 8.4 1.5 13 5.3 122 10 133 305 1.6 0.1 2.2 1.5 05/23/2005 11:00:00 8.9 1.3 12.6 6.1 8.8 1.2 12.2 5.7 125 13 127 305 1.7 0.1 2.5 1.5 05/23/2005 11:10:00 8.7 1.1 11.5 5.3 8.5 1.2 12.2 5.7 120 9 130 305 1.7 0.1 2.2 1.5 05/23/2005 11:20:00 8.2 1.1 11.1 4.9 8.1 1.1 11.5 4.9 121 13 136 305 1.8 0.1 2.2 1.5 05/23/2005 11:30:00 9.9 1.5 13.7 6.5 9.7 1.5 13.7 6.1 134 11 144 305 1.9 0 2.2 1.7 05/23/2005 11:40:00 10.7 1 13 7.6 10.5 1 13.3 7.6 131 7 129 305 2 0 2.5 2 05/23/2005 11:50:00 10.1 1.1 12.6 6.8 9.8 1.1 12.6 6.8 131 7 133 305 2.2 0.1 2.9 2 05/23/2005 12:00:00 10.8 0.8 12.2 8 10.6 0.9 12.2 8 135 4 134 305 2.3 0.1 2.9 2.2 05/23/2005 12:10:00 11 0.9 13.3 8 10.7 0.9 13.3 8 134 5 135 305 2.5 0.1 2.9 2.2 05/23/2005 12:20:00 11 0.8 12.6 8 10.9 0.9 13 7.6 133 6 129 305 2.5 0.1 2.9 2.2 05/23/2005 12:30:00 11.4 0.9 13.3 8.4 11.1 1 13.7 7.2 134 5 133 305 2.6 0 3.2 2.5 05/23/2005 12:40:00 12.2 0.7 13.3 9.1 12 0.7 13.7 8.8 132 4 133 305 2.6 0 3.2 2.5 05/23/2005 12:50:00 11.8 0.6 13.3 9.9 11.8 0.6 13.3 9.5 132 3 133 305 2.4 0 2.9 2.2 05/23/2005 13:00:00 10.3 1.2 12.6 6.5 10.2 1.2 12.2 6.8 131 7 130 305 2.3 0.1 2.7 2.2 05/23/2005 13:10:00 9.6 1.3 13 6.5 9.4 1.3 12.6 4.6 122 9 108 305 2.1 0 2.5 2 05/23/2005 13:20:00 9.4 1.3 13.7 6.5 9.3 1.3 13.7 6.5 122 11 116 305 1.9 0.2 2.5 1.7 05/23/2005 13:30:00 10 1.5 13 5.7 9.9 1.4 13.3 6.8 127 11 113 305 1.8 0.1 2.2 1.5 05/23/2005 13:40:00 11 1.2 14.1 7.2 10.9 1.2 13.7 7.6 132 9 139 305 1.8 0.1 2.2 1.5 05/23/2005 13:50:00 12 1 14.1 6.8 11.8 1 13.7 8 133 6 139 305 1.8 0.1 2.2 1.5 05/23/2005 14:00:00 12 0.7 13.3 9.5 11.7 0.7 13.3 9.5 132 4 123 305 1.7 0.1 2.2 1.5 05/23/2005 14:10:00 11.1 0.8 12.6 8.4 10.9 0.7 12.6 8.8 133 4 128 305 1.7 0.1 2.2 1.5 05/23/2005 14:20:00 11.2 0.8 13 8.4 11 0.8 12.6 8 132 4 128 305 1.6 0 2.2 1.3 05/23/2005 14:30:00 11.1 1 13 8.4 10.9 0.9 13 8.8 133 4 133 305 1.4 0 2 1.3 05/23/2005 14:40:00 11.9 0.6 13.3 9.5 11.7 0.7 13.3 9.5 131 3 129 305 1.3 0.1 1.7 1.3 05/23/2005 14:50:00 11.6 0.7 13.7 9.5 11.4 0.7 13 9.5 133 4 134 305 1.4 0 2 1.3 05/23/2005 15:00:00 11.6 0.7 13 9.9 11.3 0.7 12.6 9.5 135 4 136 305 1.6 0 2.2 1.5 05/23/2005 15:10:00 10.7 0.9 13 7.6 10.5 0.9 13 8.4 138 6 140 305 1.6 0 2.2 1.3 05/23/2005 15:20:00 10.7 0.7 12.6 8.8 10.5 0.7 13 8.4 137 5 133 305 1.5 0 2 1.3 05/23/2005 15:30:00 11.5 0.7 13.3 9.5 11.2 0.7 13 9.5 137 4 140 305 1.6 0 2.2 1.5 05/23/2005 15:40:00 11.8 0.8 13.3 9.5 11.5 0.8 13.3 8.8 137 4 138 305 1.6 0 2.2 1.5 05/23/2005 15:50:00 11.4 0.8 13 9.5 11.2 0.8 13 8.8 138 4 130 305 1.6 0 2.2 1.5 05/23/2005 16:00:00 11.3 0.7 13 9.1 11.1 0.7 12.6 9.1 138 4 125 305 1.7 0.1 2.2 1.5 05/23/2005 16:10:00 11.3 0.7 13 9.1 11.1 0.8 13 8.8 139 4 140 305 1.9 0.1 2.5 1.7 05/23/2005 16:20:00 10.7 0.8 12.6 8.8 10.5 0.7 12.2 8.4 138 5 138 305 1.9 0 2.2 1.7 05/23/2005 16:30:00 11.3 0.7 12.6 9.1 11.1 0.8 13 8.8 136 4 137 305 1.9 0.1 2.5 1.7 05/23/2005 16:40:00 11.9 0.6 13 9.9 11.7 0.7 13 8.8 133 4 138 305 1.8 0.1 2.2 1.5 05/23/2005 16:50:00 12.3 0.6 13.3 9.9 12.1 0.6 13.3 9.9 133 3 133 305 1.7 0.1 2.2 1.5 05/23/2005 17:00:00 12.1 0.6 13.3 9.9 11.9 0.7 13 9.5 134 3 135 305 1.6 0.1 2.2 1.5 05/23/2005 17:10:00 12 0.5 13 10.3 11.8 0.6 13 9.9 134 3 134 305 1.6 0 2.2 1.5 05/23/2005 17:20:00 11.3 0.7 13 8.8 11.1 0.7 12.6 8.8 135 3 136 305 1.6 0.1 2.2 1.5 05/23/2005 17:30:00 11.2 0.7 12.6 8.8 10.8 0.8 12.6 8.4 135 4 128 305 1.5 0 2 1.3 05/23/2005 17:40:00 11 0.6 12.2 9.1 10.8 0.7 12.2 8.8 134 3 131 305 1.4 0 2 1.3 05/23/2005 17:50:00 10.2 0.7 11.8 8.4 10 0.7 11.8 8 135 4 136 305 1.4 0 2 1.3 05/23/2005 18:00:00 10.1 0.7 11.5 8 9.9 0.7 11.5 8 132 4 131 305 1.6 0 2.2 1.3 05/23/2005 18:10:00 10.9 0.5 12.2 9.1 10.6 0.6 11.8 8.8 131 3 132 305 1.5 0 2.2 1.3 05/23/2005 18:20:00 11.1 0.5 12.2 9.1 10.8 0.5 11.8 8.8 131 3 134 305 1.6 0 2.2 1.3 05/23/2005 18:30:00 11 0.5 11.8 9.5 10.7 0.5 11.8 9.1 132 5 131 305 1.8 1.2 11.8 1.3 05/23/2005 18:40:00 10.4 0.7 11.8 8 10.2 0.7 11.8 8 135 4 131 305 1.7 1.8 15.1 1.3 05/23/2005 18:50:00 9.6 0.6 11.1 7.6 9.4 0.6 11.1 7.6 138 5 134 305 1.3 0.1 2 1.3 05/23/2005 19:00:00 9 0.7 10.7 7.2 8.9 0.7 10.7 7.2 137 5 136 305 1.2 0.1 1.7 1 05/23/2005 19:10:00 9.4 0.8 11.5 7.2 9.3 0.8 11.1 7.2 138 5 147 305 1.2 0.1 1.7 1 05/23/2005 19:20:00 9.8 0.6 11.1 8 9.6 0.6 11.1 7.6 137 4 137 305 1.1 0 1.5 1 05/23/2005 19:30:00 9.1 0.7 10.7 7.2 8.9 0.6 10.3 7.2 136 5 135 305 1.1 0 1.5 1 05/23/2005 19:40:00 8.5 0.7 9.9 6.5 8.4 0.7 9.9 6.1 133 4 137 305 1.1 0.1 1.5 1 05/23/2005 19:50:00 8.7 0.6 9.9 6.8 8.5 0.6 9.9 6.8 130 4 133 305 1.1 0 1.5 1 05/23/2005 20:00:00 8.1 0.8 9.5 5.7 8 0.8 9.5 5.7 130 6 119 305 1.1 0 1.5 1 05/23/2005 20:10:00 7.7 1.1 10.7 5.3 7.5 1 10.3 4.9 131 8 138 305 1 0 1.5 0.8 05/23/2005 20:20:00 8.1 1.1 11.5 4.9 7.9 1.1 11.5 5.3 133 7 127 305 0.9 0 1.3 0.8 05/23/2005 20:30:00 8.3 1.2 11.1 4.6 8.2 1.2 11.1 4.9 132 10 136 305 0.8 0 1.3 0.8 05/23/2005 20:40:00 7.7 1.5 11.1 4.2 7.7 1.2 10.3 4.2 122 11 118 305 0.9 0 1.3 0.8 05/23/2005 20:50:00 8.9 1.4 12.6 5.3 8.6 1.3 11.8 5.3 121 9 120 305 0.9 0 1.5 0.8 05/23/2005 21:00:00 9.8 1.4 13 4.9 9.7 1.3 12.6 5.3 121 9 120 305 0.9 0 1.5 0.8 05/23/2005 21:10:00 10.4 1.2 13.7 6.1 10.1 1.3 13.7 4.6 120 7 121 305 0.9 0 1.3 0.8 05/23/2005 21:20:00 10.8 1.2 13 7.2 10.6 1.2 12.6 5.7 118 6 126 305 0.8 0 1.3 0.8 05/23/2005 21:30:00 10.8 1 13.7 7.6 10.5 1 13.7 8 117 8 106 305 0.8 0 1 0.6 05/23/2005 21:40:00 10.1 1.3 13.3 7.2 10 1.3 13.7 6.8 121 9 120 305 0.8 0 1 0.6 05/23/2005 21:50:00 9.7 1.2 13 6.5 9.7 1.2 13.3 6.5 123 11 125 305 0.9 0 1 0.8 05/23/2005 22:00:00 9.9 1.1 12.2 7.2 9.9 1.1 12.6 6.8 121 11 116 305 0.9 0 1.3 0.8 05/23/2005 22:10:00 9.6 1.3 12.6 6.5 9.6 1.3 13 6.5 126 10 138 305 0.9 0 1.3 0.8 05/23/2005 22:20:00 11.5 0.8 13 8.4 11.2 0.9 13 8 130 5 130 305 0.9 0 1.3 0.8 05/23/2005 22:30:00 11.5 0.9 13.3 8.8 11.2 0.9 13 8.8 130 5 133 305 0.9 0 1.3 0.8 05/23/2005 22:40:00 11.9 0.9 14.1 8.4 11.7 0.9 13.7 8.4 129 6 133 305 0.8 0 1.3 0.8 05/23/2005 22:50:00 11.5 1 13.3 8.4 11.3 1 13.3 7.6 129 6 130 305 0.8 0 1 0.6 05/23/2005 23:00:00 12 0.8 14.1 9.1 11.6 0.9 13.3 9.1 129 5 132 305 0.8 0 1.3 0.8 05/23/2005 23:10:00 11.8 0.8 13.3 9.1 11.5 0.9 14.1 9.1 130 5 131 305 0.8 0 1.3 0.6 05/23/2005 23:20:00 11.8 0.8 13.3 8 11.6 0.9 13.3 8.8 129 5 133 305 0.8 0 1.3 0.6 05/23/2005 23:30:00 11 1.2 14.1 8 10.9 1.1 13 7.6 128 7 126 305 0.8 0 1 0.6 05/23/2005 23:40:00 11.4 1.1 13.7 8.4 11.5 1.1 13.7 8 130 7 121 305 0.9 0 1.3 0.8 05/23/2005 23:50:00 11.6 0.9 13.7 8.8 11.4 0.9 13.7 8.4 130 5 136 305 0.9 0 1.3 0.8 05/24/2005 00:00:00 11.8 0.7 13.3 9.1 11.5 0.7 13 8.8 131 4 129 305 0.9 0 1.3 0.8 05/24/2005 00:10:00 11.2 0.9 13 6.5 10.9 1 13 6.5 130 4 131 305 0.8 0 1.3 0.6 05/24/2005 00:20:00 11.1 0.8 13.7 8.4 10.9 0.8 13 8 130 4 134 305 0.7 0 1 0.6 05/24/2005 00:30:00 10.4 1 12.2 7.2 10.2 0.9 11.8 8 130 5 126 305 0.8 0 1.3 0.6 05/24/2005 00:40:00 10.2 1.2 12.6 6.8 9.9 1.2 12.2 6.1 130 6 130 305 0.8 0 1 0.8 05/24/2005 00:50:00 10.3 0.9 12.2 7.6 10.1 0.9 12.2 7.6 129 6 138 305 0.8 0 1.3 0.6 05/24/2005 01:00:00 9.8 1.2 13 6.1 9.6 1.2 12.6 5.7 128 8 137 305 0.8 0 1.3 0.6 05/24/2005 01:10:00 10 1.2 12.6 6.1 9.7 1.2 12.6 6.5 129 8 136 305 0.8 0 1 0.6 05/24/2005 01:20:00 11 1 13.3 7.2 10.6 1 13 6.8 131 6 131 305 0.9 0 1.3 0.8 05/24/2005 01:30:00 10.9 1.2 14.9 7.6 10.6 1.2 14.5 6.8 131 7 141 305 0.9 0 1.3 0.8 05/24/2005 01:40:00 11 1.5 15.6 6.8 10.8 1.6 15.3 6.8 132 9 140 305 1 0 1.3 0.8 05/24/2005 01:50:00 11.1 1.5 14.5 7.6 10.9 1.4 14.5 7.6 133 9 141 305 1 0 1.3 1 05/24/2005 02:00:00 10.6 1.6 14.5 6.1 10.3 1.7 14.5 6.5 131 9 139 305 1 0 1.3 0.8 05/24/2005 02:10:00 11.4 0.9 13.3 8.8 11.2 0.9 13.3 8.4 131 6 119 305 1 0 1.3 0.8 05/24/2005 02:20:00 11.1 0.6 12.6 8.8 10.8 0.7 12.6 8.8 132 3 136 305 1 0 1.5 0.8 05/24/2005 02:30:00 9.9 1.2 12.2 5.7 9.6 1.2 11.8 5.3 131 7 134 305 1 0 1.3 0.8 05/24/2005 02:40:00 7.9 1.5 12.2 4.2 7.7 1.5 11.1 4.6 131 11 142 305 1 0 1.5 0.8 05/24/2005 02:50:00 6.9 1.5 11.5 3.8 6.8 1.6 12.2 3.4 130 14 119 305 1 0 1.3 0.8 05/24/2005 03:00:00 6.5 1.2 10.3 3.8 6.4 1.2 9.5 3.4 128 11 134 305 0.9 0 1.3 0.8 05/24/2005 03:10:00 7.3 1.2 10.7 4.6 7.2 1.2 10.3 4.9 131 12 128 305 1 0 1.3 0.8 05/24/2005 03:20:00 8.3 1.1 10.7 4.6 8.2 1 10.7 5.3 124 10 103 305 0.9 0 1.3 0.8 05/24/2005 03:30:00 8.2 1.1 11.1 5.7 8 1.1 12.2 5.7 123 10 129 305 0.9 0 1.3 0.8 05/24/2005 03:40:00 8.4 1.2 12.2 4.9 8.2 1.1 11.8 5.3 123 9 116 305 0.9 0 1.3 0.8 05/24/2005 03:50:00 7.1 1.3 11.5 3.8 7 1.4 11.1 3.4 121 13 133 305 0.9 0 1.3 0.8 05/24/2005 04:00:00 5.7 1.3 10.3 2.3 5.5 1.2 8.8 3 110 19 116 305 0.9 0 1.3 0.8 05/24/2005 04:10:00 5.5 1.5 9.9 2.3 5.3 1.4 9.5 2.3 115 22 87 305 0.9 0 1.3 0.8 05/24/2005 04:20:00 5.7 1.9 10.3 0.4 5.6 2 11.1 0.4 124 21 148 305 0.9 0 1.3 0.8 05/24/2005 04:30:00 8.6 1.5 13.3 4.6 8.4 1.5 13 5.3 121 13 135 305 1 0 1.5 1 05/24/2005 04:40:00 7.7 1.6 11.5 3.4 7.5 1.5 11.1 3.8 119 15 145 305 1 0 1.5 1 05/24/2005 04:50:00 7.6 1.5 11.1 4.2 7.2 1.5 10.7 4.2 115 15 126 305 1.2 0 1.5 1 05/24/2005 05:00:00 6.7 1.4 10.7 3 6.6 1.3 10.3 3.8 109 15 130 305 1.1 0 1.5 1 05/24/2005 05:10:00 5.2 1.2 9.1 1.9 5.1 1.2 8.4 2.3 105 17 131 305 1 0 1.5 1 05/24/2005 05:20:00 4.4 1.2 8.4 1.9 4.2 1.1 7.2 1.9 98 24 99 305 1 0 1.5 1 05/24/2005 05:30:00 5.1 1.5 10.3 1.5 5 1.5 9.5 1.9 73 17 71 305 1 0 1.5 1 05/24/2005 05:40:00 5.5 1.5 10.3 1.5 5.2 1.5 9.5 0.4 72 21 77 305 1 0 1.5 1 05/24/2005 05:50:00 4.2 1.7 9.5 0.7 4.2 1.6 9.9 1.1 83 49 79 305 1.2 0.1 1.5 1 05/24/2005 06:00:00 3.9 1.6 8 0.4 4 1.4 7.6 0.4 39 41 47 305 1.2 0 1.5 1 05/24/2005 06:10:00 3.5 1.2 7.2 0.4 3.4 1.2 7.2 0.7 59 28 39 305 1.2 0.1 1.5 1 05/24/2005 06:20:00 5.9 1.5 10.3 2.3 5.7 1.5 9.9 2.3 92 20 96 305 1.2 0 1.5 1 05/24/2005 06:30:00 7.1 1.5 11.5 4.2 7.1 1.6 12.6 3.8 107 15 106 305 1.2 0.1 1.5 1 05/24/2005 06:40:00 7.6 1.4 12.2 4.9 7.4 1.3 11.8 4.6 109 15 88 305 1.2 0.1 1.5 1 05/24/2005 06:50:00 6.9 1.6 12.2 3.4 6.7 1.5 11.8 3.8 99 16 118 305 1.2 0 1.5 1 05/24/2005 07:00:00 6.4 1.3 9.9 2.6 6.2 1.4 9.5 2.3 93 20 81 305 1.2 0.1 1.5 1 05/24/2005 07:10:00 6.7 1.8 11.1 2.6 6.5 1.7 11.5 2.6 83 21 98 305 1.2 0 1.5 1 05/24/2005 07:20:00 6.8 1.8 11.5 3 6.7 1.9 11.5 2.3 74 16 75 305 1.2 0.1 1.5 1 05/24/2005 07:30:00 7.3 1.1 11.8 3.8 7 1.1 10.7 4.9 67 9 72 305 1.2 0.1 1.5 1 05/24/2005 07:40:00 6.4 1.5 11.8 3 6.3 1.4 12.2 3.4 66 13 78 305 1.2 0 1.5 1 05/24/2005 07:50:00 3.6 1.5 8.8 0.7 3.7 1.3 7.6 0.7 90 38 67 305 1.2 0 1.5 1 05/24/2005 08:00:00 3.3 1.4 6.8 0.4 3.2 1.3 7.2 0.4 106 51 135 305 1.3 0 2 1 05/24/2005 08:10:00 6.3 1.7 11.5 1.9 6.2 1.6 11.8 2.3 127 22 136 305 1.5 0 2 1.3 05/24/2005 08:20:00 8.7 1.7 13.7 4.6 8.5 1.7 13 3.8 123 13 131 305 1.6 0 2 1.5 05/24/2005 08:30:00 9 1.9 13 4.6 8.7 1.8 12.6 4.2 123 13 120 305 1.6 0 2.2 1.5 05/24/2005 08:40:00 8.6 2.1 14.1 3.8 8.3 2 14.5 3.8 120 18 139 305 1.6 0.1 2.2 1.5 05/24/2005 08:50:00 7.1 1.7 12.2 3.8 6.8 1.7 12.2 3 121 18 143 305 1.7 0.1 2.2 1.5 05/24/2005 09:00:00 5.8 1.4 9.9 1.9 5.7 1.5 10.7 2.6 112 22 122 305 1.7 0.1 2.2 1.5 05/24/2005 09:10:00 6.5 1.5 11.1 2.3 6.2 1.4 10.3 3 100 22 119 305 1.6 0 2.2 1.3 05/24/2005 09:20:00 6.4 1.8 12.2 2.3 6.2 1.7 11.5 2.3 105 24 61 305 1.5 0 2 1.3 05/24/2005 09:30:00 5.4 1.3 9.9 1.9 5.2 1.3 9.1 1.1 112 26 105 305 1.6 0 2.2 1.5 05/24/2005 09:40:00 7.7 2.4 14.1 3 7.3 2.4 13.7 2.6 119 17 138 305 1.6 0.1 2.2 1.5 05/24/2005 09:50:00 10.6 1.5 15.3 7.2 10.3 1.5 14.1 5.7 122 11 125 305 1.6 0 2.2 1.5 05/24/2005 10:00:00 9.4 2 14.5 4.6 9.1 2 14.1 3.4 123 15 116 305 1.6 0.1 2.2 1.5 05/24/2005 10:10:00 8.4 1.6 13.3 4.6 8.3 1.6 13 4.6 123 17 133 305 1.7 0.1 2.2 1.5 05/24/2005 10:20:00 7.5 2 11.8 2.6 7.1 1.9 11.5 2.6 112 19 128 305 1.6 0.1 2.2 1.5 05/24/2005 10:30:00 7.1 1.9 11.5 2.6 7 1.7 11.8 2.3 115 21 122 305 1.6 0 2 1.5 05/24/2005 10:40:00 7.2 1.7 11.8 3.4 6.9 1.6 11.1 2.6 117 19 148 305 1.6 0.1 2 1.3 05/24/2005 10:50:00 8.5 1.7 13.3 3.8 8.2 1.7 12.6 3.8 126 16 134 305 1.6 0.1 2.2 1.5 05/24/2005 11:00:00 8.2 1.7 13.7 4.6 8 1.7 13.7 4.6 122 17 106 305 1.7 0.1 2.2 1.5 05/24/2005 11:10:00 8.6 1.5 12.6 4.9 8.3 1.5 12.2 5.3 126 14 106 305 1.8 0.1 2.2 1.5 05/24/2005 11:20:00 9.1 1.6 15.3 5.3 9 1.5 14.5 5.3 132 13 149 305 1.8 0.1 2.2 1.5 05/24/2005 11:30:00 10.2 1.9 16.1 5.3 9.9 1.8 16.8 5.7 134 13 129 305 1.7 0.1 2.2 1.5 05/24/2005 11:40:00 9.6 1.7 13.7 6.1 9.3 1.5 13.3 5.7 133 13 122 305 1.8 0.1 2.2 1.7 05/24/2005 11:50:00 9 1.5 12.6 4.9 8.7 1.5 13.3 4.6 126 14 150 305 1.7 0.1 2.2 1.5 05/24/2005 12:00:00 8.6 1.7 13.3 4.6 8.4 1.7 13 4.2 130 15 124 305 1.8 0.2 2.2 1.5 05/24/2005 12:10:00 10.9 1.7 14.9 6.8 10.6 1.7 14.5 6.8 135 11 132 305 1.7 0.1 2.2 1.5 05/24/2005 12:20:00 11.4 1.4 15.3 7.6 11.2 1.3 14.5 7.2 133 10 121 305 1.7 0.1 2.2 1.5 05/24/2005 12:30:00 11.5 1.6 16.1 6.8 11.2 1.5 15.3 6.8 133 9 137 305 1.6 0.1 2.2 1.5 05/24/2005 12:40:00 10.8 1.7 14.9 6.8 10.6 1.7 16.1 6.5 133 10 147 305 1.7 0.1 2.2 1.5 05/24/2005 12:50:00 11.4 1.2 14.9 8 11.1 1.3 14.1 8.4 134 8 130 305 1.8 0.1 2.5 1.5 05/24/2005 13:00:00 11.7 1.3 14.5 8 11.2 1.2 13.7 7.6 135 7 130 305 1.9 0.1 2.5 1.7 05/24/2005 13:10:00 11.9 1.3 14.5 7.2 11.6 1.3 14.5 6.8 133 6 141 305 1.9 0.1 2.5 1.7 05/24/2005 13:20:00 11.6 1.3 16.4 7.6 11.3 1.3 16.1 6.5 133 9 144 305 1.9 0 2.5 1.7 05/24/2005 13:30:00 11.3 1.6 16.4 7.2 11 1.7 16.4 5.7 135 10 133 305 1.9 0.1 2.5 1.7 05/24/2005 13:40:00 10.3 1.3 14.1 6.1 10 1.3 14.1 6.5 132 11 137 305 1.9 0.1 2.5 1.7 05/24/2005 13:50:00 9.9 1.5 14.1 6.1 9.8 1.5 14.1 6.1 133 11 150 305 1.9 0 2.5 1.7 05/24/2005 14:00:00 10.6 1.6 14.9 4.6 10.4 1.5 13.7 4.9 133 10 139 305 2 0.1 2.5 2 05/24/2005 14:10:00 11 1.6 16.1 5.7 10.9 1.5 16.1 6.5 134 9 141 305 1.9 0.1 2.5 1.7 05/24/2005 14:20:00 10 1.9 17.6 5.3 9.8 1.8 14.9 5.7 129 12 129 305 2.1 0.1 2.7 2 05/24/2005 14:30:00 8.5 1.3 13.3 5.3 8.4 1.3 12.6 5.3 125 13 149 305 2.3 0.1 2.7 2.2 05/24/2005 14:40:00 9.1 1.8 15.3 5.3 9.1 1.7 15.3 5.3 130 14 142 305 2.2 0 2.7 2 05/24/2005 14:50:00 11.1 1.6 15.3 6.8 10.9 1.7 16.1 6.8 133 9 134 305 1.9 0 2.5 2 05/24/2005 15:00:00 12 1.1 15.3 8.8 11.7 1 14.9 8.4 133 7 143 305 2 0 2.5 2 05/24/2005 15:10:00 12.8 0.9 14.5 9.5 12.4 0.9 14.5 9.5 134 5 133 305 2 0 2.5 2 05/24/2005 15:20:00 11.6 1.2 14.5 8 11.3 1.2 14.5 7.6 134 6 135 305 2 0 2.5 2 05/24/2005 15:30:00 12.1 0.9 14.1 9.5 11.8 0.9 13.7 8.8 134 5 140 305 2 0 2.5 2 05/24/2005 15:40:00 12.5 1 15.3 9.1 12.1 1 14.5 9.1 133 5 139 305 2 0 2.5 2 05/24/2005 15:50:00 12.3 1.1 14.5 8.8 11.8 1.1 14.1 8.8 135 6 134 305 1.9 0 2.5 1.7 05/24/2005 16:00:00 11.9 0.8 13.7 9.5 11.4 0.9 13.3 9.1 134 6 124 305 1.9 0.1 2.5 1.7 05/24/2005 16:10:00 11.5 1 14.5 8.8 11.2 1.1 14.1 7.6 134 7 146 305 1.9 0 2.5 1.7 05/24/2005 16:20:00 11.2 1 13.3 8.4 10.9 1 13.3 8.4 135 7 137 305 1.9 0 2.5 1.7 05/24/2005 16:30:00 11.2 0.9 13.7 8.8 11 0.9 14.1 8.8 135 6 132 305 1.9 0 2.2 1.7 05/24/2005 16:40:00 11.1 0.9 12.6 7.6 10.7 1 13 7.2 133 6 130 305 1.9 0.1 2.2 1.5 05/24/2005 16:50:00 10.6 1.2 13.3 7.6 10.2 1.1 12.6 6.8 132 6 129 305 1.9 0 2.2 1.7 05/24/2005 17:00:00 10.6 1.1 13 6.8 10.2 1.1 12.6 6.8 133 7 136 305 1.9 0 2.2 1.7 05/24/2005 17:10:00 11.3 1.3 14.9 7.6 10.8 1.4 14.5 7.2 132 8 130 305 1.9 0 2.2 1.7 05/24/2005 17:20:00 11.4 1.2 14.5 7.2 10.9 1.3 14.1 7.2 133 8 120 305 1.9 0 2.5 1.7 05/24/2005 17:30:00 10.9 1.2 14.9 7.6 10.6 1.2 14.9 7.2 133 7 124 305 1.9 0 2.5 1.7 05/24/2005 17:40:00 11.9 1.7 16.8 6.8 11.6 1.6 16.4 7.6 133 8 150 305 1.9 0 2.2 1.7 05/24/2005 17:50:00 11.8 1.3 15.3 8 11.4 1.3 15.3 8 134 10 134 305 1.9 0.1 2.5 1.7 05/24/2005 18:00:00 11.7 1.5 16.4 7.2 11.4 1.5 15.6 7.6 134 8 134 305 1.9 0.1 2.5 1.7 05/24/2005 18:10:00 10.9 1.3 14.1 7.2 10.5 1.3 13.7 7.2 133 8 128 305 1.8 0.1 2.2 1.7 05/24/2005 18:20:00 11.3 1.4 14.9 7.6 10.9 1.5 14.5 7.2 132 9 129 305 1.9 0.1 2.2 1.7 05/24/2005 18:30:00 11.9 1.3 14.9 8.4 11.5 1.2 14.5 8 133 8 140 305 1.9 0.1 2.2 1.7 05/24/2005 18:40:00 12.1 1.8 18.3 8 11.8 1.8 18.3 7.6 135 10 137 305 1.8 0.1 2.2 1.5 05/24/2005 18:50:00 12.3 1.3 16.1 9.1 12.1 1.2 16.4 8.4 133 8 134 305 1.9 0 2.5 1.7 05/24/2005 19:00:00 12.4 1.6 17.2 6.8 12.1 1.6 15.6 6.8 134 9 146 305 1.9 0.1 2.5 1.7 05/24/2005 19:10:00 13.1 1.4 17.6 9.5 12.7 1.3 16.4 9.5 133 6 142 305 1.9 0.1 2.5 1.7 05/24/2005 19:20:00 12.9 1.5 16.8 8.8 12.5 1.3 15.6 9.1 133 8 133 305 1.8 0.1 2.2 1.7 05/24/2005 19:30:00 12.3 1 14.5 9.5 11.9 1 14.1 9.1 134 6 127 305 1.7 0.1 2.2 1.5 05/24/2005 19:40:00 11.4 1.2 14.5 8.4 11.1 1.1 14.9 8.4 134 5 138 305 1.7 0.1 2.2 1.5 05/24/2005 19:50:00 11.1 1.2 14.1 7.6 10.7 1.2 13.7 7.6 134 6 131 305 1.7 0.1 2.2 1.5 05/24/2005 20:00:00 10.7 1.2 13 7.2 10.2 1.2 13 7.2 132 6 126 305 1.7 0.2 2.2 1.5 05/24/2005 20:10:00 11.3 1.5 15.6 6.8 11 1.5 15.6 6.5 134 9 144 305 1.8 0.1 2.2 1.5 05/24/2005 20:20:00 11.8 1.3 15.6 8.4 11.3 1.3 14.5 7.6 133 8 139 305 1.9 0.1 2.5 1.7 05/24/2005 20:30:00 11.9 1.4 16.4 8 11.6 1.3 14.1 7.2 133 8 125 305 1.9 0 2.5 1.7 05/24/2005 20:40:00 12.5 1.7 16.8 8.8 12 1.6 16.4 8.4 133 9 140 305 2 0 2.5 2 05/24/2005 20:50:00 12.8 1.3 16.4 8.8 12.2 1.3 15.3 6.8 133 7 135 305 2 0 2.5 2 05/24/2005 21:00:00 12.3 1.4 16.1 8 11.9 1.5 16.8 7.6 133 9 138 305 2 0 2.5 2 05/24/2005 21:10:00 11.9 1.3 16.1 6.5 11.4 1.4 14.9 7.2 133 8 133 305 1.9 0 2.5 2 05/24/2005 21:20:00 11.1 1.6 15.6 6.8 10.7 1.5 15.3 6.5 133 10 135 305 1.9 0.1 2.5 2 05/24/2005 21:30:00 10.4 1.7 14.5 5.7 10.1 1.7 14.5 4.9 134 12 143 305 1.9 0 2.5 1.7 05/24/2005 21:40:00 10.3 1.5 14.9 6.8 10.1 1.6 14.1 6.5 137 11 145 305 1.9 0 2.5 2 05/24/2005 21:50:00 10.2 1.9 15.6 5.3 9.9 1.8 15.3 4.6 135 12 129 305 1.9 0 2.5 1.7 05/24/2005 22:00:00 9.6 2.1 15.3 4.9 9.5 2 15.3 4.6 134 14 153 305 2 0.1 2.5 2 05/24/2005 22:10:00 7.6 1.6 13 4.6 7.3 1.5 12.6 4.6 125 16 127 305 1.8 0.1 2.2 1.5 05/24/2005 22:20:00 7.9 1.7 12.2 3.8 7.7 1.7 11.8 3.8 124 15 129 305 1.7 0.1 2.2 1.5 05/24/2005 22:30:00 8.5 2 13.7 3.8 8.2 1.8 13.7 4.2 126 15 123 305 1.9 0.1 2.5 1.7 05/24/2005 22:40:00 8.2 1.6 13 4.9 7.9 1.5 12.6 4.2 125 16 119 305 1.9 0.1 2.5 1.7 05/24/2005 22:50:00 8.6 2.1 14.1 4.6 8.2 2 13.3 4.2 125 17 113 305 1.9 0 2.5 1.7 05/24/2005 23:00:00 8.5 1.8 13.3 4.2 8 1.8 13.3 3.8 123 16 124 305 1.9 0.1 2.5 1.7 05/24/2005 23:10:00 8.4 2.1 14.9 3.8 8.2 2.1 13.7 3.8 126 16 143 305 1.9 0.1 2.5 1.7 05/24/2005 23:20:00 8.3 1.8 14.1 3.4 7.8 1.7 13.3 3.4 129 17 131 305 1.9 0.1 2.5 1.7 05/24/2005 23:30:00 8.6 1.9 13.3 4.9 8.6 1.8 13.7 4.6 131 17 114 305 1.9 0 2.5 1.7 05/24/2005 23:40:00 10.3 1.7 15.3 6.8 10.1 1.7 14.5 6.5 132 13 144 305 1.9 0.1 2.5 1.7 05/24/2005 23:50:00 9.5 1.7 15.6 5.7 9.4 1.7 15.3 5.3 135 14 138 305 1.7 0.1 2.2 1.5 05/25/2005 00:00:00 10.9 2.1 15.6 6.8 10.8 2.2 16.1 6.5 135 13 130 305 1.6 0.1 2.2 1.5 05/25/2005 00:10:00 13.2 1.7 18.3 8 12.6 1.7 17.2 7.2 136 9 140 305 1.8 0.1 2.5 1.5 05/25/2005 00:20:00 14.3 1.7 18.7 9.1 13.8 1.7 17.9 8.8 134 9 136 305 1.9 0 2.5 1.7 05/25/2005 00:30:00 14.2 1.6 18.7 10.3 13.9 1.5 18.3 9.9 134 8 134 305 1.9 0 2.5 2 05/25/2005 00:40:00 14.2 1.4 17.9 10.7 13.7 1.5 17.2 8.8 134 7 133 305 1.9 0 2.5 2 05/25/2005 00:50:00 13.8 1.6 17.6 8 13.3 1.5 17.2 9.1 135 8 133 305 1.9 0 2.5 1.7 05/25/2005 01:00:00 13.5 1.6 17.2 9.5 13.1 1.5 16.8 9.9 134 7 135 305 1.9 0 2.5 1.7 05/25/2005 01:10:00 13.5 1.5 17.6 9.1 13 1.4 16.1 8.4 134 7 136 305 1.9 0 2.5 1.7 05/25/2005 01:20:00 13 1.5 16.4 7.2 12.7 1.4 16.8 8.8 135 7 137 305 1.8 0 2.2 1.7 05/25/2005 01:30:00 13.4 1.3 17.6 9.9 13 1.5 17.6 9.1 135 7 129 305 1.7 0.1 2.2 1.5 05/25/2005 01:40:00 12.7 1.7 16.8 8 12.3 1.7 17.2 7.6 136 10 141 305 1.7 0 2.2 1.5 05/25/2005 01:50:00 13 1.5 17.2 9.5 12.7 1.5 16.8 8.8 137 9 146 305 1.7 0 2.2 1.5 05/25/2005 02:00:00 13 1.5 16.8 8.8 12.5 1.7 16.8 7.6 135 9 123 305 1.6 0 2.2 1.5 05/25/2005 02:10:00 13 1.5 16.4 8.8 12.7 1.6 16.8 7.6 137 9 121 305 1.6 0 2.2 1.5 05/25/2005 02:20:00 12 2 17.2 7.2 11.7 1.9 16.4 7.6 138 11 136 305 1.6 0 2.2 1.5 05/25/2005 02:30:00 12.3 1.7 18.7 8.4 12.1 1.6 17.6 8.8 142 12 147 305 1.7 0.1 2.2 1.5 05/25/2005 02:40:00 12.2 1.7 18.3 8 12.1 1.7 18.7 8 142 10 146 305 1.7 0 2.2 1.5 05/25/2005 02:50:00 11.9 1.9 16.8 7.2 11.7 1.7 16.8 6.8 140 11 142 305 1.6 0 2.2 1.5 05/25/2005 03:00:00 12 1.7 16.1 8.4 11.9 1.6 16.8 8 142 11 132 305 1.7 0.1 2.2 1.5 05/25/2005 03:10:00 12.2 1.7 16.8 8 11.9 1.5 16.8 8 142 11 147 305 1.7 0.1 2.2 1.5 05/25/2005 03:20:00 12.1 1.7 17.6 8.4 11.8 1.7 17.6 7.6 142 10 145 305 1.6 0 2.2 1.5 05/25/2005 03:30:00 11.8 1.6 17.2 7.2 11.7 1.6 16.4 8 144 10 142 305 1.6 0 2.2 1.5 05/25/2005 03:40:00 13.1 2 19.5 8 12.7 1.7 17.6 8 144 9 129 305 1.7 0.1 2.2 1.5 05/25/2005 03:50:00 13.1 1.7 18.3 9.1 12.7 1.4 16.8 9.1 145 9 142 305 1.6 0 2.2 1.5 05/25/2005 04:00:00 12.6 1.6 17.2 7.6 12.4 1.5 17.6 8 146 9 150 305 1.7 0.1 2.2 1.5 05/25/2005 04:10:00 12.8 1.8 17.2 7.6 12.5 1.7 16.4 8 147 9 156 305 1.7 0.1 2.2 1.5 05/25/2005 04:20:00 12.9 1.7 17.6 7.6 12.5 1.5 16.8 8.8 145 9 150 305 1.6 0.1 2.2 1.5 05/25/2005 04:30:00 13.1 1.5 18.3 8.4 12.6 1.3 16.1 8.8 146 8 140 305 1.6 0 2.2 1.5 05/25/2005 04:40:00 12.8 1.8 16.8 7.2 12.6 1.6 16.4 8.4 148 9 151 305 1.7 0.1 2.2 1.5 05/25/2005 04:50:00 12.7 1.7 16.8 6.8 12.3 1.6 16.4 8.4 147 9 146 305 1.6 0.1 2.2 1.5 05/25/2005 05:00:00 13 1.7 17.6 8.8 12.4 1.7 17.2 8.4 147 8 135 305 1.6 0 2.2 1.5 05/25/2005 05:10:00 12.3 2.2 18.3 5.7 12.2 1.8 17.9 6.5 148 10 165 305 1.6 0.1 2.2 1.5 05/25/2005 05:20:00 12.3 2 17.6 6.5 12 1.7 18.7 8 148 10 156 305 1.7 0.1 2.2 1.5 05/25/2005 05:30:00 12.6 2 16.8 6.5 12.4 1.7 16.8 7.6 148 10 150 305 1.7 0.1 2.2 1.5 05/25/2005 05:40:00 12.2 2.2 17.9 8 12.2 1.8 17.6 7.6 149 11 154 305 1.7 0.1 2.2 1.5 05/25/2005 05:50:00 11.3 1.7 17.2 6.8 11.4 1.5 16.4 8 149 11 150 305 1.6 0.1 2.2 1.5 05/25/2005 06:00:00 12 2.2 17.2 6.1 12 1.8 16.4 6.5 150 11 151 305 1.7 0.1 2.2 1.5 05/25/2005 06:10:00 13.1 1.8 17.9 6.8 12.9 1.5 17.2 8.8 149 9 140 305 1.7 0.1 2.2 1.5 05/25/2005 06:20:00 13 1.9 16.8 7.2 12.7 1.7 17.2 8.8 148 10 135 305 1.6 0 2.2 1.5 05/25/2005 06:30:00 12.8 2 17.2 7.6 12.5 1.8 16.8 7.6 149 9 155 305 1.6 0.1 2.2 1.5 05/25/2005 06:40:00 13.4 2 18.7 7.2 12.9 1.7 17.9 8.8 147 9 150 305 1.7 0.1 2.2 1.5 05/25/2005 06:50:00 13.6 2.1 17.9 8 13.4 1.7 18.7 8.4 150 10 147 305 1.8 0.1 2.2 1.7 05/25/2005 07:00:00 13.3 2.3 19.9 5.7 13.4 2 18.7 8.8 149 11 136 305 1.7 0.1 2.2 1.5 05/25/2005 07:10:00 13.7 2.2 18.7 7.2 13.5 1.8 18.3 8.4 148 9 128 305 1.7 0.1 2.2 1.5 05/25/2005 07:20:00 14.1 1.8 19.9 8.4 13.8 1.7 19.9 9.5 147 9 155 305 1.7 0.1 2.2 1.5 05/25/2005 07:30:00 13.6 2.2 19.9 6.8 13.5 1.9 19.1 8.8 149 9 146 305 1.7 0.1 2.2 1.5 05/25/2005 07:40:00 14.2 2.1 18.7 8.4 14 1.8 18.7 8.4 148 10 141 305 1.7 0.1 2.2 1.5 05/25/2005 07:50:00 13.3 1.8 17.9 7.2 13.1 1.5 16.8 9.5 150 9 152 305 1.7 0.1 2.2 1.5 05/25/2005 08:00:00 13.2 2.5 19.1 6.8 13.3 2 19.5 8.8 150 10 158 305 1.8 0.2 2.2 1.5 05/25/2005 08:10:00 12.5 2.5 18.3 6.5 12.8 2.1 18.3 8.8 152 11 152 305 1.7 0.1 2.2 1.5 05/25/2005 08:20:00 13 2.2 17.9 7.2 13.2 1.8 18.3 8.8 152 11 153 305 1.9 0.1 2.2 1.7 05/25/2005 08:30:00 13.7 2.3 20.2 7.6 13.9 1.8 19.9 9.9 154 9 153 305 2 0 2.5 2 05/25/2005 08:40:00 15.3 2.3 21.4 6.8 15.3 1.8 21 10.3 150 9 154 305 1.9 0.1 2.5 1.7 05/25/2005 08:50:00 16.5 1.7 22.6 11.5 16 1.6 21.4 12.2 149 6 152 305 1.9 0 2.2 1.7 05/25/2005 09:00:00 15.9 2.2 21 10.3 15.6 1.9 20.6 10.7 150 7 152 305 1.9 0 2.5 1.7 05/25/2005 09:10:00 15.4 2.5 19.9 8.8 15.3 2.1 19.5 9.9 151 8 161 305 2 0 2.5 2 05/25/2005 09:20:00 14 2 19.5 9.1 14 1.7 19.5 9.5 152 9 152 305 2.1 0 2.7 2 05/25/2005 09:30:00 14.5 2.1 19.1 8.4 14.5 1.7 19.1 9.9 150 8 144 305 2.2 0 2.7 2 05/25/2005 09:40:00 14.2 1.7 17.9 8 14 1.5 17.9 9.9 150 7 145 305 2 0 2.5 2 05/25/2005 09:50:00 14.6 1.5 19.1 10.3 14.1 1.3 17.2 10.3 149 7 156 305 2 0 2.5 2 05/25/2005 10:00:00 14.4 1.5 18.3 10.3 13.9 1.4 17.2 9.5 147 7 150 305 1.9 0 2.5 1.7 05/25/2005 10:10:00 13.5 1.5 17.6 9.1 13 1.6 16.8 8.4 147 7 156 305 1.9 0 2.5 1.7 05/25/2005 10:20:00 11.8 1.8 17.2 7.6 11.6 1.6 16.8 8 149 9 144 305 1.9 0 2.5 1.7 05/25/2005 10:30:00 12.8 1.7 17.2 8 12.5 1.5 17.2 8.4 144 9 134 305 2 0 2.5 2 05/25/2005 10:40:00 13.1 1.6 17.2 9.5 12.8 1.5 17.2 9.9 136 7 136 305 2.1 0 2.7 2 05/25/2005 10:50:00 12.2 1.6 17.9 8 11.8 1.5 17.9 8 136 7 143 305 2.1 0 2.5 2 05/25/2005 11:00:00 12.9 1.2 17.6 9.9 12.4 1.2 16.1 9.1 137 7 152 305 2.2 0 2.7 2 05/25/2005 11:10:00 13.1 1.4 16.8 9.5 12.6 1.5 16.4 8.4 134 7 138 305 2.2 0.1 2.7 2.2 05/25/2005 11:20:00 12.4 1.7 16.8 7.6 12 1.6 16.1 8 133 8 129 305 2.3 0.1 2.7 2.2 05/25/2005 11:30:00 12.8 1.8 18.7 7.6 12.4 1.8 18.3 8 137 10 147 305 2.3 0.1 2.9 2.2 05/25/2005 11:40:00 12.3 2 16.4 7.6 11.9 1.9 16.1 7.2 143 9 143 305 2.2 0.1 2.7 2.2 05/25/2005 11:50:00 11.7 1.7 16.1 7.2 11.3 1.7 15.3 6.8 145 10 156 305 2.2 0.1 2.7 2.2 05/25/2005 12:00:00 10.8 1.6 14.5 6.1 10.5 1.5 14.1 6.5 142 10 151 305 2.2 0 2.7 2.2 05/25/2005 12:10:00 11.5 1.4 15.3 8 11.1 1.4 14.1 7.6 135 9 154 305 2.2 0 2.7 2 05/25/2005 12:20:00 11.9 1.1 14.5 8.8 11.5 1 14.1 8.4 135 6 141 305 2.2 0 2.7 2.2 05/25/2005 12:30:00 12.2 1.2 15.3 8.4 11.8 1.2 15.3 7.6 135 6 137 305 2.2 0 2.7 2.2 05/25/2005 12:40:00 11.9 1.1 14.9 8 11.5 1 14.5 8.4 135 6 139 305 2.3 0.1 2.7 2.2 05/25/2005 12:50:00 12.7 1.2 15.6 9.9 12.3 1.1 14.9 9.1 134 6 130 305 2.1 0 2.7 2 05/25/2005 13:00:00 13.3 1.2 16.1 9.9 12.9 1.1 15.6 9.9 134 6 139 305 2 0 2.2 2 05/25/2005 13:10:00 13.4 1.3 16.4 9.5 13 1.3 16.4 9.1 131 7 134 305 2 0 2.5 2 05/25/2005 13:20:00 14.2 1.8 17.9 8.8 13.8 1.9 19.1 8 134 8 140 305 2.1 0 2.5 2 05/25/2005 13:30:00 14 1.8 19.1 8.8 13.6 1.9 17.9 8.4 134 9 137 305 2.1 0 2.5 2 05/25/2005 13:40:00 13.1 1.4 16.8 9.1 12.5 1.4 16.1 8.8 134 8 138 305 2 0 2.5 2 05/25/2005 13:50:00 13.3 1.3 17.2 9.5 12.8 1.3 16.1 9.9 133 6 136 305 2 0 2.5 2 05/25/2005 14:00:00 14.9 1.5 19.5 11.5 14.4 1.5 18.3 10.3 132 7 137 305 2.2 0.1 2.7 2.2 05/25/2005 14:10:00 14.4 1.5 18.3 10.7 13.9 1.3 17.2 9.5 133 5 136 305 2.2 0 2.5 2 05/25/2005 14:20:00 14.4 1.5 17.6 10.3 13.9 1.5 17.2 9.9 132 6 138 305 2 0 2.5 2 05/25/2005 14:30:00 13.3 1 16.1 9.9 12.9 1.1 16.1 10.3 134 6 138 305 1.9 0 2.5 2 05/25/2005 14:40:00 13.7 1 16.4 9.1 13.1 1.2 16.1 9.1 134 5 137 305 2 0 2.5 2 05/25/2005 14:50:00 13.8 1.4 17.2 9.5 13.3 1.4 16.8 9.5 134 6 144 305 2 0 2.5 2 05/25/2005 15:00:00 14 1.3 17.2 10.3 13.5 1.3 17.2 9.5 134 5 138 305 2.2 0 2.5 2 05/25/2005 15:10:00 12 1.7 17.9 7.6 11.8 1.7 17.2 6.8 137 10 135 305 2.2 0 2.7 2.2 05/25/2005 15:20:00 12.8 1.7 16.4 7.6 12.5 1.7 16.4 6.8 136 9 134 305 2.3 0.1 2.7 2.2 05/25/2005 15:30:00 14.3 1.3 18.3 10.7 14 1.3 17.6 10.7 135 6 143 305 2.4 0 2.9 2.2 05/25/2005 15:40:00 14.8 1.3 17.6 10.7 14.3 1.3 17.2 10.7 134 6 134 305 2.5 0 2.9 2.5 05/25/2005 15:50:00 14.9 1.5 17.9 10.3 14.5 1.5 17.6 10.3 134 6 135 305 2.6 0 2.9 2.5 05/25/2005 16:00:00 13.5 1.4 17.2 9.1 13.1 1.3 16.4 9.1 136 7 136 305 2.5 0 2.9 2.5 05/25/2005 16:10:00 13.5 1.6 18.3 8.8 13.2 1.6 18.3 9.5 135 9 130 305 2.6 0 2.9 2.5 05/25/2005 16:20:00 15.2 1.5 18.7 11.1 14.6 1.5 19.9 9.9 135 6 130 305 2.7 0 3.2 2.5 05/25/2005 16:30:00 12.7 1.7 16.8 8.8 12.5 1.7 16.4 8.8 139 10 149 305 2.8 0 3.4 2.5 05/25/2005 16:40:00 13.9 1.6 19.5 9.9 13.4 1.6 19.5 9.5 137 8 133 305 2.9 0.1 3.4 2.7 05/25/2005 16:50:00 13.5 1.3 17.6 9.5 13.2 1.3 17.6 9.5 136 7 147 305 2.8 0.1 3.2 2.5 05/25/2005 17:00:00 13.3 1 15.6 10.7 12.8 1 15.3 10.3 133 6 127 305 2.6 0 3.2 2.5 05/25/2005 17:10:00 13.7 0.9 16.1 11.1 13.2 0.9 15.6 11.1 133 4 140 305 2.5 0 2.9 2.5 05/25/2005 17:20:00 13.6 1 15.6 11.1 13.1 1 14.9 10.7 133 5 133 305 2.5 0 2.9 2.5 05/25/2005 17:30:00 13.3 1 15.6 10.3 12.9 1.1 15.3 9.9 133 5 129 305 2.5 0 2.7 2.2 05/25/2005 17:40:00 13.6 1.2 16.8 10.3 13.3 1.2 17.2 10.3 135 6 135 305 2.5 0.1 2.7 2.2 05/25/2005 17:50:00 13.6 1.3 17.9 9.5 13.3 1.4 17.2 9.1 135 6 131 305 2.5 0 2.9 2.2 05/25/2005 18:00:00 13.2 1.1 16.1 10.3 12.7 1.1 15.6 9.5 135 5 137 305 2.4 0.1 2.7 2.2 05/25/2005 18:10:00 13.4 1.1 15.6 9.5 13 1.1 15.3 10.3 133 5 131 305 2.3 0.1 2.7 2.2 05/25/2005 18:20:00 12.8 1.3 16.1 8.8 12.3 1.3 15.6 8.4 132 8 134 305 2.6 0 2.9 2.5 05/25/2005 18:30:00 13 1.5 16.4 8.4 12.5 1.5 16.1 8.4 134 8 133 305 2.7 0 2.9 2.5 05/25/2005 18:40:00 12.6 1.5 16.4 7.2 12 1.3 16.1 7.2 133 7 130 305 2.8 0.1 3.2 2.7 05/25/2005 18:50:00 13 1.5 17.2 9.1 12.5 1.5 16.4 8.4 132 8 131 305 3.1 0 3.4 2.9 05/25/2005 19:00:00 13.1 1.4 17.2 8 12.7 1.5 16.4 7.6 133 8 148 305 3.3 0 3.7 2.9 05/25/2005 19:10:00 13 1.5 16.8 8.4 12.6 1.5 16.4 8.8 133 6 133 305 3.4 0.2 3.9 3.2 05/25/2005 19:20:00 13.3 1 15.6 10.3 12.7 1 14.9 9.1 135 5 133 305 3.4 0.2 3.7 3.2 05/25/2005 19:30:00 13.5 1.2 16.4 9.5 13 1.1 16.1 9.5 134 5 136 305 3.4 0.1 3.7 3.2 05/25/2005 19:40:00 13.5 1.2 16.4 9.9 12.9 1.1 15.6 9.5 134 6 116 305 3.3 0.1 3.7 3.2 05/25/2005 19:50:00 13.2 1 15.3 9.1 12.6 1 15.3 9.5 134 5 144 305 3.4 0.2 3.9 3.2 05/25/2005 20:00:00 11.9 1 13.7 8.4 11.4 1 13.7 8.8 134 6 139 305 3.5 0.1 4.2 3.2 05/25/2005 20:10:00 11.3 1 14.1 8.4 10.9 1 13.7 8 133 6 135 305 3.7 0 4.2 3.4 05/25/2005 20:20:00 11.3 1.2 14.9 7.6 10.8 1.3 14.5 7.2 133 8 141 305 3.9 0.2 4.4 3.7 05/25/2005 20:30:00 10.2 1.9 14.9 5.3 9.9 1.8 14.1 5.7 132 11 131 305 4.2 0.1 4.7 4.2 05/25/2005 20:40:00 8.4 1.7 13.7 4.9 8.2 1.6 13.3 4.6 126 14 121 305 4.4 0.1 4.9 4.2 05/25/2005 20:50:00 9.9 1.7 13.7 6.1 9.5 1.6 14.5 6.1 128 13 115 305 4.5 0.2 4.9 4.4 05/25/2005 21:00:00 10.2 2 16.4 6.1 9.9 1.9 16.4 6.5 131 13 133 305 4.6 0.1 4.9 4.4 05/25/2005 21:10:00 11.6 1.7 16.1 7.2 11 1.7 16.1 7.2 133 11 134 305 4.7 0 5.2 4.4 05/25/2005 21:20:00 12.3 1.1 14.9 9.1 11.9 1.1 14.9 9.1 134 6 132 305 4.7 0 4.9 4.4 05/25/2005 21:30:00 12.3 1.3 16.8 9.5 11.7 1.3 16.4 7.6 135 6 159 305 4.8 0 5.2 4.7 05/25/2005 21:40:00 11.3 1.7 14.9 5.7 11.1 1.5 14.9 6.5 140 12 130 305 5 0.1 5.4 4.7 05/25/2005 21:50:00 11 1.8 15.3 6.8 10.7 1.7 15.6 6.1 141 12 154 305 4.9 0.1 5.4 4.9 05/25/2005 22:00:00 10.7 1.6 14.9 6.8 10.4 1.4 13.7 6.8 147 10 150 305 5.2 0.1 5.9 4.9 05/25/2005 22:10:00 10.3 1.7 16.1 6.1 10.2 1.6 14.9 6.5 145 11 145 305 5.3 0.2 5.9 4.9 05/25/2005 22:20:00 9.6 1.7 14.1 5.7 9.6 1.6 14.9 5.7 145 13 150 305 5.2 0.2 5.9 4.9 05/25/2005 22:30:00 9.7 1.6 13.7 5.7 9.5 1.3 13.3 6.1 141 13 143 305 5.2 0.2 5.6 4.9 05/25/2005 22:40:00 9.6 1.7 13.7 3.8 9.2 1.6 13 4.9 140 11 144 305 5.3 0.2 5.9 4.9 05/25/2005 22:50:00 10.7 1.7 14.9 5.7 10.3 1.7 14.5 6.8 135 10 126 305 5.4 0.1 5.9 5.2 05/25/2005 23:00:00 8.6 1.8 13.7 3.8 8.4 1.7 12.6 4.2 131 13 140 305 5.3 0.1 5.9 4.9 05/25/2005 23:10:00 8.8 1.7 13.3 4.6 8.4 1.6 12.6 4.6 130 13 136 305 5.3 0.1 5.9 4.9 05/25/2005 23:20:00 7.5 1.8 13 3 7.2 1.6 11.8 2.6 132 15 139 305 5.3 0 5.9 4.9 05/25/2005 23:30:00 6.1 2.5 13 0.7 5.8 2.2 12.2 1.9 100 32 113 305 5.3 0.2 5.9 4.9 05/25/2005 23:40:00 5.5 1.6 9.1 0.4 5.3 1.6 9.1 0.4 84 33 78 305 4.8 0.2 5.4 4.4 05/25/2005 23:50:00 6.3 2 11.5 1.9 6 1.9 12.6 2.6 97 26 81 305 4.2 0.3 5.2 3.7 05/26/2005 00:00:00 6.1 1.7 11.1 2.3 5.8 1.7 11.5 2.3 118 22 110 305 5 0.2 5.6 4.7 05/26/2005 00:10:00 6.5 1.8 13 3 6.3 1.7 12.2 2.6 125 18 112 305 5.4 0.1 5.9 5.2 05/26/2005 00:20:00 5.3 2.5 12.2 0.4 5.3 2.4 14.1 1.1 114 30 116 305 5.5 0.1 5.9 5.2 05/26/2005 00:30:00 3.9 1.5 8 0.4 3.8 1.3 8 1.5 85 32 64 305 5.3 0.1 5.9 4.9 05/26/2005 00:40:00 4.5 1.4 9.5 0.7 4.5 1.3 8 1.5 84 22 73 305 5 0.2 5.6 4.7 05/26/2005 00:50:00 6.5 1.5 10.3 1.9 6.4 1.4 10.3 3 75 16 69 305 4.4 0.2 4.9 4.2 05/26/2005 01:00:00 6.5 1.4 10.3 3 6.2 1.4 10.7 2.6 86 18 90 305 4.8 0.2 5.4 4.4 05/26/2005 01:10:00 7.9 1.8 13 4.2 7.8 1.7 12.6 4.2 79 16 64 305 5.2 0.2 5.9 4.9 05/26/2005 01:20:00 7.2 1.3 12.2 3.4 7 1.5 12.6 3 82 17 82 305 5.5 0.2 5.9 5.4 05/26/2005 01:30:00 6.6 1.6 11.1 2.3 6.4 1.7 11.1 1.5 89 19 101 305 5.7 0.2 6.4 5.4 05/26/2005 01:40:00 6.5 1.5 9.9 2.6 6.3 1.5 9.9 2.6 98 21 80 305 5.9 0.1 6.4 5.6 05/26/2005 01:50:00 6.3 1.6 9.9 3 6.1 1.5 9.9 2.6 86 18 68 305 5.2 0.4 6.4 4.7 05/26/2005 02:00:00 6.8 1.4 11.5 3.8 6.6 1.3 11.1 3.8 103 22 114 305 5 0.3 5.9 4.7 05/26/2005 02:10:00 6 1.5 9.9 2.3 5.8 1.4 10.3 2.6 112 21 111 305 5.6 0.1 6.1 5.4 05/26/2005 02:20:00 5 1.4 8.8 1.5 4.8 1.4 9.5 0.7 106 26 127 305 5.7 0.2 6.1 5.4 05/26/2005 02:30:00 5.5 1.3 9.5 1.1 5.4 1.4 8.8 1.1 76 19 54 305 4.7 0.3 5.6 4.2 05/26/2005 02:40:00 6.1 1.3 9.9 3.4 5.8 1.2 9.5 2.6 87 17 112 305 4.1 0.1 4.7 3.9 05/26/2005 02:50:00 7.2 1.2 11.1 4.6 7.1 1.2 11.1 4.2 78 12 77 305 4 0.2 4.7 3.7 05/26/2005 03:00:00 6.8 1.2 10.3 4.2 6.6 1.2 9.5 3.8 83 13 68 305 4.3 0.2 4.9 3.9 05/26/2005 03:10:00 6.5 1.1 9.9 3.8 6.3 1 9.5 4.2 83 15 80 305 4.8 0.1 5.6 4.7 05/26/2005 03:20:00 7.1 1.1 9.9 4.9 7 1.1 10.3 4.6 85 16 71 305 5.3 0.3 5.9 4.9 05/26/2005 03:30:00 7.3 1.3 10.7 4.2 7.1 1.3 11.5 4.2 88 13 90 305 5.6 0.2 6.1 5.4 05/26/2005 03:40:00 7.7 1.2 11.8 4.9 7.3 1.2 11.5 4.2 90 13 98 305 5.8 0.1 6.1 5.6 05/26/2005 03:50:00 7.4 1.2 10.3 3.8 7.3 1.2 10.7 4.2 90 13 65 305 5.5 0.2 6.1 5.2 05/26/2005 04:00:00 8.1 1.1 10.3 5.3 7.8 1.2 10.7 3.8 90 11 84 305 5 0.1 5.6 4.7 05/26/2005 04:10:00 7.9 1.4 12.2 4.9 7.7 1.3 11.8 4.2 89 11 72 305 5.4 0.3 6.4 4.7 05/26/2005 04:20:00 7.3 1.1 10.3 4.6 6.9 1.1 9.5 3.8 89 12 97 305 6 0.1 6.4 5.6 05/26/2005 04:30:00 7.3 1.3 11.5 4.9 6.9 1.2 10.7 4.2 89 12 84 305 6.3 0.2 6.9 5.9 05/26/2005 04:40:00 8.5 1.3 11.5 5.3 8 1.2 12.2 4.6 91 11 81 305 6.8 0.1 7.2 6.4 05/26/2005 04:50:00 8.1 1.1 11.1 4.6 7.5 1.1 10.3 5.3 90 9 85 305 6.7 0.1 7.2 6.4 05/26/2005 05:00:00 8.3 0.9 11.1 5.7 7.7 0.8 9.1 5.7 91 6 88 305 6.4 0 6.9 6.1 05/26/2005 05:10:00 7.6 0.7 9.1 5.3 7 0.6 8.4 5.3 93 6 93 305 6.7 0.1 7.2 6.4 05/26/2005 05:20:00 7.5 0.8 9.9 4.9 6.9 0.8 9.1 4.9 97 5 102 305 6.1 0.2 6.7 5.9 05/26/2005 05:30:00 8.6 0.9 11.1 6.1 7.9 0.8 9.9 5.7 94 5 92 305 5.6 0.1 5.9 5.4 05/26/2005 05:40:00 8.8 0.9 11.1 6.5 8.2 0.8 9.9 6.5 91 5 85 305 5 0.1 5.6 4.7 05/26/2005 05:50:00 8.9 0.7 10.7 6.8 8.3 0.6 9.9 6.5 88 5 85 305 5.3 0.2 5.9 4.9 05/26/2005 06:00:00 8.9 0.7 10.7 6.8 8.2 0.8 10.7 6.1 89 6 87 305 5.6 0.1 6.1 5.4 05/26/2005 06:10:00 8.3 0.7 10.3 6.5 7.6 0.7 9.1 5.7 84 7 83 305 5.8 0.2 6.4 5.4 05/26/2005 06:20:00 8.5 0.8 9.9 6.5 7.8 0.7 9.9 6.5 84 6 87 305 6 0 6.4 5.9 05/26/2005 06:30:00 8.8 0.8 11.1 7.2 8.2 0.8 10.3 6.1 81 6 90 305 5.8 0 6.4 5.6 05/26/2005 06:40:00 8.3 0.6 9.9 6.8 7.8 0.6 9.1 6.5 79 5 80 305 5.6 0.2 6.4 5.4 05/26/2005 06:50:00 8.3 0.8 11.1 6.8 7.9 0.8 10.7 6.1 81 6 80 305 6 0 6.4 5.9 05/26/2005 07:00:00 8.3 1 10.7 6.1 8 1 10.3 5.3 72 7 81 305 5.9 0 6.4 5.4 05/26/2005 07:10:00 8.5 0.8 10.7 6.5 8.2 0.8 9.9 5.7 69 9 85 305 5.4 0.3 6.1 4.9 05/26/2005 07:20:00 8.3 0.7 10.7 6.5 8.1 0.8 10.3 6.1 72 6 79 305 5.9 0.2 6.4 5.4 05/26/2005 07:30:00 7.4 0.7 9.5 5.3 7.2 0.8 9.5 5.3 70 7 71 305 6.1 0.1 6.4 5.6 05/26/2005 07:40:00 8.9 0.7 10.7 7.2 8.7 0.7 10.3 6.8 62 4 62 305 5.5 0.1 5.9 5.2 05/26/2005 07:50:00 9.3 0.6 11.1 6.8 9.1 0.6 11.5 6.5 62 4 70 305 5.6 0.1 5.9 5.4 05/26/2005 08:00:00 9.4 0.5 10.7 8 9.2 0.5 10.7 7.6 61 4 64 305 5.7 0 6.1 5.6 05/26/2005 08:10:00 9.6 0.6 11.5 7.6 9.4 0.7 11.8 7.2 58 4 69 305 5.9 0.2 6.1 5.4 05/26/2005 08:20:00 9.8 1 12.6 7.2 9.7 1 11.8 6.5 64 7 62 305 6 0.2 6.7 5.4 05/26/2005 08:30:00 10.5 0.8 12.2 8 10.4 0.8 11.8 8 60 4 62 305 5.4 0.3 5.9 4.7 05/26/2005 08:40:00 9 0.9 11.8 6.8 8.6 1 11.5 6.1 75 7 67 305 5.5 0.2 5.9 4.9 05/26/2005 08:50:00 9 0.8 11.5 6.5 8.6 0.9 10.7 6.1 72 9 77 305 5.2 0.3 5.6 4.4 05/26/2005 09:00:00 9.4 0.4 10.3 8 9.2 0.5 10.3 7.2 56 3 60 305 4 0.2 4.4 3.7 05/26/2005 09:10:00 8.6 0.6 9.9 6.8 8.4 0.6 9.9 6.5 51 3 54 305 3.6 0.1 4.2 3.2 05/26/2005 09:20:00 8.3 0.4 9.5 7.2 8.2 0.4 9.1 7.2 50 3 54 305 3.4 0.1 3.7 3.2 05/26/2005 09:30:00 8.5 0.5 10.3 7.6 8.4 0.5 9.5 6.8 54 5 56 305 3.2 0.1 3.7 2.9 05/26/2005 09:40:00 8.8 0.6 10.3 6.8 8.9 0.5 10.3 7.6 56 5 58 305 3.2 0 3.7 2.9 05/26/2005 09:50:00 9.2 0.6 10.3 7.6 9.3 0.5 10.3 8 56 5 47 305 3.1 0 3.7 2.9 05/26/2005 10:00:00 8.6 0.4 9.5 7.6 8.8 0.4 9.9 7.2 56 5 56 305 3.1 0.2 3.7 2.7 05/26/2005 10:10:00 8.4 0.5 9.1 6.8 8.4 0.4 9.5 7.2 54 5 48 305 2.9 0.2 3.4 2.7 05/26/2005 10:20:00 8.5 0.3 9.5 7.6 8.3 0.4 9.5 7.2 49 3 47 305 2.8 0.2 3.4 2.7 05/26/2005 10:30:00 8.3 0.3 9.1 7.2 8.2 0.4 9.1 6.8 51 3 50 305 2.8 0.1 3.4 2.7 05/26/2005 10:40:00 8.1 0.4 9.1 7.2 8.1 0.4 9.1 6.5 50 4 51 305 2.8 0.2 3.4 2.5 05/26/2005 10:50:00 8.3 0.3 9.1 7.2 8.3 0.3 9.1 7.2 52 3 50 305 2.6 0.1 3.2 2.5 05/26/2005 11:00:00 7.9 0.5 9.1 6.1 8.2 0.4 9.1 7.2 55 4 58 305 2.6 0.2 3.2 2.2 05/26/2005 11:10:00 7.3 0.4 8.8 6.1 7.7 0.4 8.8 6.8 58 4 54 305 2.9 0.2 3.4 2.7 05/26/2005 11:20:00 7.5 0.3 8.4 6.5 7.9 0.3 8.4 6.8 51 4 54 305 2.9 0.2 3.4 2.5 05/26/2005 11:30:00 7.1 0.3 8 6.1 7.2 0.3 8 6.5 49 3 46 305 2.9 0.2 3.4 2.7 05/26/2005 11:40:00 6.9 0.3 7.6 6.1 7.1 0.3 7.6 6.1 47 2 46 305 2.8 0.2 3.4 2.5 05/26/2005 11:50:00 6.8 0.3 7.6 6.1 6.9 0.3 7.6 6.1 42 5 37 305 2.7 0.1 3.2 2.5 05/26/2005 12:00:00 7 0.3 7.6 6.5 7 0.3 7.6 6.1 37 3 40 305 2.3 0.1 2.9 2.2 05/26/2005 12:10:00 7.2 0.3 8 6.5 7.2 0.3 8 6.1 33 3 34 305 2.3 0.1 2.9 2 05/26/2005 12:20:00 7.1 0.3 7.6 6.1 7 0.4 8 5.7 27 4 34 305 2.2 0.2 2.9 1.7 05/26/2005 12:30:00 6.6 0.4 7.2 4.9 6.5 0.4 7.6 5.7 28 5 24 305 2.3 0.1 2.9 2 05/26/2005 12:40:00 7.2 0.3 8 6.5 7.2 0.3 8 6.5 24 2 22 305 2 0.1 2.5 1.5 05/26/2005 12:50:00 6.9 0.4 8 6.1 6.9 0.5 8 4.9 25 3 24 305 2 0.1 2.5 1.7 05/26/2005 13:00:00 6.6 0.4 7.6 5.3 6.5 0.5 7.6 4.9 24 4 19 305 2 0.2 2.7 1.5 05/26/2005 13:10:00 6.8 0.4 8 5.7 6.8 0.4 8 5.7 27 6 14 305 2.1 0.2 2.7 1.7 05/26/2005 13:20:00 7.2 0.4 8.4 6.1 7.2 0.5 8.4 5.7 34 4 35 305 2.1 0.2 2.7 1.7 05/26/2005 13:30:00 6.5 0.5 7.6 4.9 6.4 0.6 7.6 4.9 35 5 27 305 2.2 0.1 2.7 2 05/26/2005 13:40:00 6.6 0.5 7.6 4.6 6.5 0.5 8 5.3 36 5 35 305 2.3 0.1 2.9 2 05/26/2005 13:50:00 6.5 0.5 8 4.6 6.5 0.5 8.4 4.9 39 6 37 305 2.3 0.1 2.9 2 05/26/2005 14:00:00 6.5 0.5 8 5.3 6.6 0.5 7.6 5.3 39 5 37 305 2.3 0.1 2.7 2 05/26/2005 14:10:00 6.6 0.5 7.6 5.3 6.6 0.5 7.6 4.9 36 5 36 305 2.2 0.2 2.7 2 05/26/2005 14:20:00 6.8 0.5 8 5.3 6.7 0.5 8 5.3 34 5 30 305 2.3 0.2 2.9 2 05/26/2005 14:30:00 6.9 0.4 8 5.7 6.9 0.4 8 5.7 35 5 31 305 2.3 0.1 2.9 2.2 05/26/2005 14:40:00 6.5 0.4 8 5.3 6.6 0.4 7.6 5.3 33 4 44 305 2.5 0.1 3.2 2.2 05/26/2005 14:50:00 6.4 0.4 7.6 5.3 6.4 0.4 7.6 5.3 34 5 40 305 2.7 0.2 3.2 2.2 05/26/2005 15:00:00 6 0.4 6.8 4.6 6.1 0.5 7.6 4.6 33 5 35 305 2.4 0 2.9 2.2 05/26/2005 15:10:00 5.7 0.4 7.2 4.9 5.7 0.5 6.8 4.6 37 6 31 305 2.3 0.1 2.7 2.2 05/26/2005 15:20:00 5.5 0.5 6.8 4.2 5.5 0.5 6.8 4.2 38 6 29 305 2.6 0.2 3.2 2.2 05/26/2005 15:30:00 5.4 0.5 6.5 4.2 5.4 0.5 6.8 4.6 37 7 24 305 2.7 0 3.2 2.5 05/26/2005 15:40:00 5.1 0.4 6.1 3.8 5.1 0.5 6.1 3.8 39 7 33 305 2.6 0.1 2.9 2.2 05/26/2005 15:50:00 5.3 0.4 6.5 4.2 5.4 0.5 6.8 4.2 39 6 38 305 2.6 0 2.9 2.5 05/26/2005 16:00:00 5.3 0.5 6.5 4.2 5.4 0.4 6.8 4.2 35 7 36 305 2.8 0.1 3.2 2.5 05/26/2005 16:10:00 5.2 0.5 6.5 3.8 5.4 0.4 6.1 4.2 34 7 33 305 2.8 0.1 3.2 2.5 05/26/2005 16:20:00 4.9 0.5 6.1 3.4 5 0.5 6.1 3.8 34 6 41 305 2.7 0 3.2 2.5 05/26/2005 16:30:00 4.5 0.4 5.7 3.4 4.5 0.4 5.7 3 39 8 35 305 2.6 0 2.7 2.5 05/26/2005 16:40:00 3.9 0.5 5.3 2.6 4.1 0.5 5.3 3 41 10 32 305 2.5 0 2.9 2.5 05/26/2005 16:50:00 3.6 0.5 4.9 1.9 3.6 0.5 4.9 2.3 41 9 32 305 2.6 0 2.9 2.5 05/26/2005 17:00:00 3.5 0.6 4.9 1.5 3.6 0.6 4.9 2.3 48 9 51 305 2.6 0 2.9 2.5 05/26/2005 17:10:00 3.6 0.5 4.9 2.3 3.8 0.5 5.3 2.6 53 8 58 305 2.5 0.1 2.7 2.2 05/26/2005 17:20:00 4 0.5 5.7 3 4.2 0.5 5.7 3 45 9 41 305 2.4 0 2.7 2.2 05/26/2005 17:30:00 4.2 0.5 5.7 3 4.3 0.5 5.7 3 43 10 31 305 2.5 0 2.7 2.2 05/26/2005 17:40:00 4.5 0.5 6.1 3 4.6 0.6 5.7 3 39 8 28 305 2.5 0 2.7 2.2 05/26/2005 17:50:00 4.7 0.6 6.1 3 4.6 0.6 6.1 3 34 9 27 305 2.7 0.1 2.9 2.5 05/26/2005 18:00:00 5 0.6 6.5 3.4 4.9 0.6 6.8 3.4 36 9 30 305 2.6 0 2.9 2.5 05/26/2005 18:10:00 5 0.5 6.8 3.8 5.1 0.5 6.5 3.8 39 6 32 305 2.5 0.1 2.7 2.2 05/26/2005 18:20:00 5.1 0.4 6.1 4.2 5.2 0.4 6.5 4.2 36 6 34 305 2.5 0 2.9 2.2 05/26/2005 18:30:00 4.9 0.5 6.5 3.8 5 0.6 6.5 3.8 36 6 31 305 2.3 0 2.7 2.2 05/26/2005 18:40:00 4.7 0.4 6.1 3.4 4.8 0.4 6.1 3.4 33 6 19 305 2.2 0 2.5 2.2 05/26/2005 18:50:00 4.6 0.4 6.1 3.4 4.7 0.4 5.7 3.8 37 6 38 305 2.3 0.1 2.7 2 05/26/2005 19:00:00 4.7 0.5 6.1 3.4 4.9 0.4 6.1 3.8 36 7 32 305 2.3 0.1 2.5 2.2 05/26/2005 19:10:00 4.9 0.5 6.1 3.8 4.9 0.4 6.1 3.8 36 6 40 305 2.3 0 2.5 2.2 05/26/2005 19:20:00 5.2 0.5 6.8 4.2 5.2 0.5 6.5 3.8 35 6 34 305 2.2 0 2.5 2.2 05/26/2005 19:30:00 6.3 0.7 8 4.9 6.2 0.7 8 4.2 30 5 27 305 2.5 0 2.7 2.2 05/26/2005 19:40:00 7.2 0.5 8.8 6.1 7.2 0.5 8.4 5.7 28 5 18 305 2.3 0.1 2.7 2.2 05/26/2005 19:50:00 7.2 0.6 8.8 5.7 7.2 0.6 8.4 5.3 29 6 24 305 2.3 0 2.7 2.2 05/26/2005 20:00:00 7.5 0.5 9.1 6.1 7.5 0.5 8.8 6.1 31 5 30 305 2.3 0.1 2.7 2.2 05/26/2005 20:10:00 7.5 0.6 9.1 6.1 7.5 0.6 9.1 5.7 30 5 21 305 2.2 0 2.5 2 05/26/2005 20:20:00 7.7 0.8 9.9 5.7 7.7 0.8 9.5 5.7 33 5 39 305 2.1 0 2.2 2 05/26/2005 20:30:00 8.3 0.5 9.5 6.5 8.3 0.5 9.5 6.8 32 5 24 305 2 0 2.2 2 05/26/2005 20:40:00 7.9 0.6 9.5 6.5 8 0.6 9.5 6.5 35 6 33 305 2.3 0.1 2.7 2 05/26/2005 20:50:00 8 0.7 9.5 6.5 8 0.6 9.9 6.5 38 6 36 305 2.4 0 2.9 2.2 05/26/2005 21:00:00 8 0.7 9.9 6.1 8 0.7 9.9 5.7 37 6 31 305 2.6 0 2.7 2.5 05/26/2005 21:10:00 7.3 0.7 9.1 5.7 7.3 0.7 9.9 5.3 39 6 37 305 2.8 0.1 3.2 2.5 05/26/2005 21:20:00 6.9 0.7 9.5 5.3 6.9 0.6 8.4 4.9 44 7 33 305 3.1 0 3.2 2.9 05/26/2005 21:30:00 7.2 0.8 9.5 5.3 7.3 0.8 9.9 5.7 45 7 42 305 3.3 0 3.7 3.2 05/26/2005 21:40:00 7.3 0.8 9.9 5.7 7.2 0.7 9.5 4.9 40 8 39 305 3.5 0 3.7 3.2 05/26/2005 21:50:00 7.6 0.9 10.7 5.7 7.4 0.9 11.1 4.6 40 9 24 305 3.8 0 4.2 3.7 05/26/2005 22:00:00 8.1 0.8 10.3 6.1 8 0.8 9.9 5.7 37 7 28 305 4 0 4.2 3.7 05/26/2005 22:10:00 7.6 0.6 9.1 6.5 7.5 0.6 9.1 6.1 37 6 37 305 3.6 0 3.9 3.4 05/26/2005 22:20:00 7 0.6 8.8 5.3 7 0.7 9.5 5.3 36 6 41 305 3.2 0.1 3.7 2.9 05/26/2005 22:30:00 6.6 0.9 10.7 5.3 6.5 0.8 9.9 4.9 37 8 27 305 3 0 3.4 2.9 05/26/2005 22:40:00 6 0.5 7.2 4.6 6 0.4 7.2 4.9 39 6 39 305 2.9 0 3.2 2.7 05/26/2005 22:50:00 6 0.7 8 4.6 5.9 0.7 8 4.6 35 7 35 305 2.8 0 3.2 2.5 05/26/2005 23:00:00 6.1 0.6 7.6 3.8 6.1 0.6 7.6 4.6 33 7 47 305 2.8 0 3.2 2.7 05/26/2005 23:10:00 6.1 0.6 8 4.6 6.3 0.6 8 4.6 37 6 44 305 2.9 0 3.2 2.7 05/26/2005 23:20:00 5.8 0.6 8 4.2 5.9 0.6 8 4.6 39 8 41 305 3.1 0 3.2 2.9 05/26/2005 23:30:00 5.1 0.7 7.2 3.4 5.1 0.6 6.8 3.8 45 9 33 305 2.9 0.1 3.2 2.7 05/26/2005 23:40:00 4.3 0.8 6.8 2.3 4.4 0.8 7.2 2.6 46 12 47 305 2.7 0 2.9 2.7 05/26/2005 23:50:00 3.5 0.6 5.7 2.3 3.5 0.6 5.3 2.3 50 12 25 305 2.6 0 2.7 2.5 05/27/2005 00:00:00 3.2 0.6 4.6 1.9 3.3 0.5 4.6 1.9 53 13 52 305 2.5 0 3.2 2.5 05/27/2005 00:10:00 3.1 0.5 4.6 1.9 3.1 0.5 4.6 1.9 58 10 52 305 2.5 0 2.7 2.5 05/27/2005 00:20:00 3.7 0.5 5.3 2.3 3.7 0.5 5.3 2.6 57 9 46 305 2.5 0 2.9 2.2 05/27/2005 00:30:00 3.9 0.5 5.3 2.6 4 0.5 5.3 2.6 53 7 49 305 2.4 0.1 2.7 2.2 05/27/2005 00:40:00 4.3 0.5 5.3 3 4.3 0.5 5.7 3 47 8 46 305 2.4 0.1 2.7 2.2 05/27/2005 00:50:00 4.9 0.6 6.5 3 4.6 0.5 6.1 3.4 37 9 31 305 2.3 0.1 2.7 2.2 05/27/2005 01:00:00 6.2 0.6 7.6 4.2 5.7 0.6 7.6 4.2 27 7 17 305 2.3 0.2 2.9 2.2 05/27/2005 01:10:00 7.4 0.6 9.1 6.1 7 0.7 8.8 5.3 20 6 21 305 2.7 0.2 3.2 2.2 05/27/2005 01:20:00 8.1 0.7 10.3 6.5 7.6 0.7 9.5 5.7 20 6 21 305 2.8 0.2 3.4 2.7 05/27/2005 01:30:00 8.8 0.6 10.7 6.8 8.4 0.6 9.9 6.5 19 5 19 305 3 0.2 3.4 2.7 05/27/2005 01:40:00 9.2 0.7 11.1 7.2 8.6 0.6 10.3 6.8 18 5 10 305 3 0.2 3.4 2.7 05/27/2005 01:50:00 9.4 0.6 11.1 7.2 8.8 0.7 10.7 6.8 18 6 17 305 3 0.2 3.4 2.7 05/27/2005 02:00:00 9 0.6 10.7 7.6 8.5 0.6 9.9 6.8 22 4 19 305 2.8 0.2 3.4 2.7 05/27/2005 02:10:00 9.4 0.6 11.1 8 8.8 0.7 11.1 6.8 20 4 16 305 2.8 0.2 3.4 2.7 05/27/2005 02:20:00 9.6 0.7 11.5 8 9.1 0.7 11.1 7.6 18 5 17 305 2.9 0.2 3.4 2.7 05/27/2005 02:30:00 9.9 0.7 11.8 7.6 9.4 0.7 11.1 7.6 17 4 19 305 3 0.2 3.4 2.7 05/27/2005 02:40:00 9.6 0.6 11.1 7.6 9 0.7 11.5 7.2 19 5 25 305 2.9 0.2 3.4 2.7 05/27/2005 02:50:00 9.4 0.7 11.5 7.6 8.8 0.6 10.7 7.2 19 5 20 305 2.8 0.1 3.4 2.7 05/27/2005 03:00:00 9.4 0.6 11.5 7.6 8.8 0.6 10.7 7.6 22 4 17 305 2.8 0 3.4 2.7 05/27/2005 03:10:00 9.1 0.5 10.3 7.6 8.6 0.6 10.3 6.8 26 5 22 305 2.7 0 3.2 2.5 05/27/2005 03:20:00 8.8 0.5 10.7 6.8 8.3 0.6 9.9 6.5 29 5 30 305 2.6 0 2.9 2.5 05/27/2005 03:30:00 8.7 0.5 10.3 7.2 8.1 0.5 9.5 6.5 29 5 24 305 2.5 0 2.9 2.2 05/27/2005 03:40:00 8.8 0.5 9.9 7.2 8.3 0.6 9.9 6.8 27 5 23 305 2.5 0 2.9 2.2 05/27/2005 03:50:00 8.2 0.5 9.9 6.5 7.9 0.5 9.1 6.5 33 5 22 305 2.5 0.1 2.9 2.2 05/27/2005 04:00:00 8.6 0.7 10.7 6.8 8 0.7 9.9 6.1 25 6 21 305 2.5 0 2.9 2.2 05/27/2005 04:10:00 9.2 0.7 10.7 7.2 8.8 0.7 10.7 7.2 20 5 18 305 2.7 0 3.2 2.5 05/27/2005 04:20:00 9.9 0.7 11.5 8 9.4 0.7 11.5 7.6 15 4 12 305 2.8 0.1 3.2 2.7 05/27/2005 04:30:00 9.2 0.8 11.1 6.8 8.7 0.8 11.1 6.8 16 5 15 305 2.8 0.1 3.2 2.7 05/27/2005 04:40:00 8.8 0.6 10.3 7.2 8.3 0.6 10.3 6.1 15 5 14 305 2.8 0.1 3.2 2.7 05/27/2005 04:50:00 8.3 0.6 10.3 6.5 7.9 0.6 9.9 6.5 19 5 14 305 2.7 0 3.2 2.5 05/27/2005 05:00:00 8.5 0.7 10.3 6.5 8 0.8 9.9 6.1 15 6 11 305 2.7 0.1 3.2 2.5 05/27/2005 05:10:00 7.8 0.6 9.5 6.1 7.3 0.6 9.1 5.7 14 5 13 305 2.8 0.1 3.2 2.7 05/27/2005 05:20:00 7.8 0.6 9.1 6.1 7.3 0.6 8.8 5.7 16 6 6 305 2.8 0.1 3.2 2.7 05/27/2005 05:30:00 8 0.7 9.9 6.5 7.4 0.8 10.3 4.9 12 7 16 305 2.9 0.1 3.4 2.7 05/27/2005 05:40:00 8.1 0.7 10.3 6.1 7.5 0.7 9.5 5.7 12 6 10 305 3.2 0 3.4 2.9 05/27/2005 05:50:00 7.8 0.6 9.1 6.5 7.4 0.6 9.5 5.7 18 5 4 305 3.1 0 3.4 2.9 05/27/2005 06:00:00 7.9 0.6 9.5 6.5 7.4 0.6 9.1 5.3 17 5 17 305 3 0 3.4 2.9 05/27/2005 06:10:00 8.3 0.7 10.3 6.5 7.8 0.7 9.5 6.1 14 5 14 305 3.1 0 3.4 2.9 05/27/2005 06:20:00 8.8 0.7 10.7 7.2 8.2 0.8 10.7 6.1 15 5 13 305 3.2 0 3.4 2.9 05/27/2005 06:30:00 10.3 0.8 12.2 7.6 9.8 0.9 12.2 7.2 13 5 8 305 3.3 0.1 3.7 2.9 05/27/2005 06:40:00 10.5 0.6 12.6 9.1 10 0.7 11.8 7.6 16 4 12 305 3.3 0 3.7 3.2 05/27/2005 06:50:00 10.1 0.8 12.6 8.4 9.5 0.8 11.8 7.6 19 5 14 305 3 0.1 3.4 2.7 05/27/2005 07:00:00 10.7 0.9 13 8.8 10.2 0.8 12.6 8 19 5 17 305 2.9 0.1 3.4 2.7 05/27/2005 07:10:00 9.5 0.6 11.5 8 8.9 0.6 10.7 7.2 20 5 23 305 2.7 0 3.2 2.7 05/27/2005 07:20:00 8.7 0.6 10.3 6.1 8.3 0.6 9.9 6.8 23 5 26 305 2.7 0.1 3.2 2.7 05/27/2005 07:30:00 8.7 0.5 10.3 7.2 8.3 0.5 9.5 6.8 35 5 27 305 2.9 0.1 3.4 2.7 05/27/2005 07:40:00 8.3 0.6 9.9 6.8 8 0.6 9.5 6.5 44 5 35 305 2.8 0.1 3.2 2.7 05/27/2005 07:50:00 8.1 0.5 9.1 6.5 8 0.6 9.1 6.5 47 5 47 305 2.8 0.1 3.2 2.5 05/27/2005 08:00:00 8.2 0.5 9.5 6.8 8.1 0.5 9.5 6.1 47 5 54 305 2.5 0.1 2.9 2.2 05/27/2005 08:10:00 9 0.6 11.1 7.6 8.6 0.6 10.3 6.8 42 4 36 305 2.2 0 2.7 2.2 05/27/2005 08:20:00 10 0.5 11.5 8.8 9.6 0.6 11.1 8.4 35 4 33 305 2.3 0.1 2.7 2.2 05/27/2005 08:30:00 9.8 0.5 11.5 8.4 9.3 0.6 10.7 7.6 33 3 33 305 2.3 0.1 2.7 2.2 05/27/2005 08:40:00 9.6 0.5 11.1 8 9.1 0.6 10.7 7.6 34 4 38 305 2.3 0.1 2.7 2.2 05/27/2005 08:50:00 9.2 0.6 11.1 7.2 8.8 0.7 10.7 6.8 37 5 39 305 2.5 0 2.9 2.2 05/27/2005 09:00:00 8.9 0.5 9.9 6.8 8.5 0.6 10.3 6.5 41 4 40 305 2.3 0.1 2.7 2.2 05/27/2005 09:10:00 9.1 0.6 10.7 7.6 8.6 0.6 10.7 7.2 41 4 44 305 2.6 0 2.9 2.2 05/27/2005 09:20:00 9.4 0.7 11.8 7.6 8.9 0.7 10.7 7.2 38 4 35 305 2.7 0 3.2 2.5 05/27/2005 09:30:00 8.3 0.6 9.9 6.5 7.9 0.7 9.5 6.1 41 4 37 305 2.8 0.1 3.2 2.5 05/27/2005 09:40:00 7.7 0.5 9.1 6.1 7.4 0.5 9.1 5.3 40 4 36 305 2.5 0 3.2 2.2 05/27/2005 09:50:00 8.2 0.5 9.9 6.8 7.9 0.6 9.5 6.5 39 5 32 305 2.7 0.1 3.2 2.5 05/27/2005 10:00:00 8.9 0.8 11.1 6.5 8.5 1 10.7 5.7 42 5 32 305 3.1 0.2 3.7 2.7 05/27/2005 10:10:00 9.7 0.7 11.8 8 9.3 0.8 11.8 7.2 42 6 31 305 3.3 0.1 3.9 2.9 05/27/2005 10:20:00 9 0.7 10.7 6.8 8.7 0.7 10.3 6.8 48 5 43 305 3.5 0.1 4.2 3.2 05/27/2005 10:30:00 8.3 0.7 9.5 6.1 8.2 0.8 9.5 5.7 56 6 49 305 3.5 0.2 4.2 3.2 05/27/2005 10:40:00 8.1 0.7 9.9 5.7 8.2 0.7 9.5 5.7 56 7 59 305 3.6 0.1 4.2 3.2 05/27/2005 10:50:00 8.3 0.8 9.9 6.1 8.3 0.8 10.3 5.7 56 8 58 305 3.4 0.1 3.9 3.2 05/27/2005 11:00:00 8.6 0.6 10.3 6.8 8.6 0.7 10.7 6.5 59 7 54 305 3.5 0.1 4.2 3.2 05/27/2005 11:10:00 8.3 0.8 11.1 6.1 8.2 0.9 10.3 5.3 58 7 60 305 3.4 0.1 3.9 3.2 05/27/2005 11:20:00 7.5 0.8 9.9 5.7 7.4 0.7 9.1 5.7 54 8 48 305 3.3 0.1 3.9 2.9 05/27/2005 11:30:00 7 0.6 8.8 5.3 7 0.6 8.4 5.3 54 7 62 305 3.4 0.2 4.2 2.9 05/27/2005 11:40:00 7.4 0.6 9.1 6.1 7.3 0.7 8.8 5.3 52 8 52 305 3.6 0.2 4.2 3.2 05/27/2005 11:50:00 7.7 0.6 9.5 6.1 7.6 0.7 9.1 5.7 51 7 48 305 3.4 0.1 3.9 2.9 05/27/2005 12:00:00 7.3 0.5 9.5 6.1 7.3 0.6 9.5 5.7 46 6 47 305 3.1 0.1 3.4 2.9 05/27/2005 12:10:00 7.2 0.6 8.8 5.3 7.1 0.6 9.1 4.9 48 5 43 305 3.1 0.1 3.7 2.9 05/27/2005 12:20:00 6.8 0.6 8.8 5.3 6.9 0.7 8.8 4.9 47 6 49 305 3.1 0.2 3.7 2.7 05/27/2005 12:30:00 6.9 0.5 8.4 5.7 6.9 0.6 8.8 5.3 43 6 38 305 3.1 0.1 3.7 2.7 05/27/2005 12:40:00 7.3 0.5 8.4 5.7 7.3 0.5 8.8 6.1 40 5 38 305 3.3 0.1 3.7 2.9 05/27/2005 12:50:00 7.3 0.5 9.1 5.7 7.2 0.5 8.4 6.1 41 5 35 305 3.2 0.1 3.7 2.9 05/27/2005 13:00:00 8.1 0.8 10.3 6.5 8 0.7 10.3 6.5 42 5 44 305 3.1 0 3.4 2.7 05/27/2005 13:10:00 9.6 0.7 11.8 8 9.4 0.8 11.8 7.6 47 6 42 305 3.3 0.3 4.2 2.7 05/27/2005 13:20:00 10 0.6 12.2 8.4 9.9 0.7 11.8 8 50 6 42 305 3.4 0.2 4.2 2.9 05/27/2005 13:30:00 10.4 0.6 12.2 8.4 10.4 0.7 12.2 8 55 5 46 305 3.4 0.2 4.2 2.9 05/27/2005 13:40:00 9.9 0.6 11.5 8 9.9 0.6 11.8 8 53 5 52 305 3.2 0 3.7 2.9 05/27/2005 13:50:00 9.6 0.6 11.8 7.2 9.4 0.6 11.1 8 49 5 43 305 3.1 0.3 4.2 2.7 05/27/2005 14:00:00 10.4 0.7 12.2 8.8 10.2 0.7 11.8 8 47 4 50 305 3.1 0.2 3.7 2.7 05/27/2005 14:10:00 10.3 0.6 11.8 8.8 10.2 0.7 11.8 7.6 47 5 44 305 2.9 0.1 3.4 2.5 05/27/2005 14:20:00 10.1 0.5 11.8 8 10 0.6 11.5 8 43 3 42 305 2.9 0.2 3.7 2.5 05/27/2005 14:30:00 10.4 0.5 11.5 8.8 10.3 0.6 11.8 8.8 42 3 50 305 2.8 0.1 3.4 2.5 05/27/2005 14:40:00 10.3 0.4 11.5 9.5 10.2 0.5 11.5 8.8 42 3 41 305 2.9 0.2 3.7 2.5 05/27/2005 14:50:00 10.6 0.4 11.5 9.5 10.5 0.5 11.8 9.1 42 3 43 305 2.8 0.1 3.4 2.5 05/27/2005 15:00:00 10.7 0.4 11.8 9.5 10.5 0.5 11.8 9.1 42 3 45 305 2.9 0.2 3.7 2.5 05/27/2005 15:10:00 10.5 0.4 11.8 9.5 10.3 0.5 11.8 8.8 44 3 37 305 2.8 0.1 3.2 2.5 05/27/2005 15:20:00 10.6 0.5 11.8 9.1 10.3 0.5 11.8 8.8 45 3 41 305 2.7 0.2 3.2 2.2 05/27/2005 15:30:00 10.3 0.5 11.8 8.8 10.3 0.6 11.8 8.4 51 5 48 305 2.8 0.2 3.4 2.2 05/27/2005 15:40:00 9.9 0.6 11.8 8 10 0.7 11.5 7.6 52 5 56 305 2.6 0.1 3.2 2.2 05/27/2005 15:50:00 9.7 0.7 11.8 7.6 9.7 0.8 11.8 8 52 6 50 305 2.6 0.1 3.2 2.2 05/27/2005 16:00:00 9.3 0.6 11.1 7.6 9.2 0.6 11.1 7.6 45 5 51 305 2.5 0.1 2.9 2.2 05/27/2005 16:10:00 8.8 0.4 9.9 7.6 8.7 0.5 9.9 7.2 41 4 38 305 2.5 0.2 3.2 2.2 05/27/2005 16:20:00 9 0.4 10.3 8 9 0.5 10.3 7.2 45 4 43 305 2.2 0.1 2.7 2 05/27/2005 16:30:00 9.2 0.6 10.7 7.6 9.3 0.7 11.1 7.6 52 5 53 305 2.4 0.1 2.7 2 05/27/2005 16:40:00 9.4 0.5 10.7 8 9.5 0.5 11.1 8 52 5 55 305 2.3 0.1 2.7 2.2 05/27/2005 16:50:00 9.4 0.6 11.1 8 9.5 0.6 11.8 7.6 51 6 60 305 2.5 0.4 3.2 2 05/27/2005 17:00:00 9.4 0.6 11.5 8 9.6 0.6 11.5 8 55 5 58 305 2.3 0.1 2.7 2 05/27/2005 17:10:00 9.5 0.6 11.1 7.6 9.5 0.6 11.1 7.6 51 6 60 305 2.2 0.1 2.7 2 05/27/2005 17:20:00 9.8 0.6 11.1 8 9.7 0.6 11.5 8 50 5 48 305 2 0 2.5 1.7 05/27/2005 17:30:00 10.1 0.6 11.5 8.4 10 0.6 11.5 8 52 4 57 305 2.1 0 2.5 2 05/27/2005 17:40:00 10.6 0.6 13 9.1 10.7 0.6 13 8.8 55 4 59 305 2 0 2.2 1.7 05/27/2005 17:50:00 10.8 0.5 12.2 8.8 10.8 0.6 12.2 8.4 56 4 52 305 2.2 0.1 2.5 2 05/27/2005 18:00:00 11.3 0.5 13.3 9.9 11.4 0.6 13.7 9.5 57 4 60 305 2 0 2.2 1.7 05/27/2005 18:10:00 11.5 0.6 13 9.5 11.4 0.7 13 9.1 58 4 54 305 2 0.1 2.5 1.7 05/27/2005 18:20:00 11.6 0.5 13.3 9.9 11.6 0.6 13 9.9 59 4 64 305 2.1 0 2.2 2 05/27/2005 18:30:00 12 0.7 13.7 9.9 12 0.7 14.1 9.9 57 4 58 305 2.2 0.1 2.5 2 05/27/2005 18:40:00 11.5 0.7 14.1 9.9 11.5 0.8 13.7 9.5 56 5 60 305 1.9 0.1 2.5 1.7 05/27/2005 18:50:00 11.4 0.6 13.3 9.9 11.3 0.7 13.3 9.9 56 4 59 305 1.9 0 2.2 1.5 05/27/2005 19:00:00 11.2 0.5 12.6 9.5 11.2 0.6 12.6 8.8 57 4 55 305 1.7 0.1 2.2 1.5 05/27/2005 19:10:00 11 0.7 13.3 9.1 11 0.7 13 9.1 55 4 59 305 1.7 0.1 2.2 1.5 05/27/2005 19:20:00 11.2 0.5 13 9.9 11.3 0.5 12.6 9.9 56 4 64 305 1.8 0.1 2.2 1.5 05/27/2005 19:30:00 11.3 0.6 13 9.5 11.3 0.7 13.3 9.1 56 4 57 305 1.6 0 2.2 1.3 05/27/2005 19:40:00 12 0.6 13.3 9.9 12 0.7 13.7 9.9 59 3 58 305 1.6 0 2 1.5 05/27/2005 19:50:00 11.8 0.5 13.3 10.3 11.7 0.6 13.3 9.1 59 3 60 305 1.6 0 2.2 1.3 05/27/2005 20:00:00 11.9 0.5 13.3 10.3 11.9 0.6 13.7 10.3 61 4 62 305 1.6 0.2 2.2 1.3 05/27/2005 20:10:00 12.3 0.6 13.7 10.7 12.3 0.8 14.1 9.5 61 5 59 305 1.8 0.2 2.2 1.5 05/27/2005 20:20:00 12.5 0.6 14.5 10.7 12.4 0.7 14.1 10.3 60 4 64 305 1.6 0.1 2.2 1.3 05/27/2005 20:30:00 12.1 0.5 13.3 9.9 12.1 0.6 13.7 9.9 61 3 61 305 1.4 0.2 2 1.3 05/27/2005 20:40:00 11.6 0.7 13.3 9.5 11.5 0.8 13.3 9.1 60 4 67 305 1.6 0.2 2.2 1.3 05/27/2005 20:50:00 11.9 0.7 13.7 9.5 11.9 0.7 13.7 9.9 61 4 64 305 1.6 0.2 2.2 1.3 05/27/2005 21:00:00 12.5 0.6 14.1 11.1 12.5 0.6 14.1 10.7 61 3 59 305 1.5 0 2 1.3 05/27/2005 21:10:00 12.2 0.5 13.3 10.3 12.2 0.5 13.7 10.3 58 3 58 305 1.2 0.1 1.5 1 05/27/2005 21:20:00 11.8 0.5 13 10.3 11.8 0.6 13 9.9 58 3 58 305 1.1 0.1 1.5 1 05/27/2005 21:30:00 11.3 0.5 13 9.9 11.3 0.6 13 9.5 58 3 62 305 1.1 0.1 1.5 1 05/27/2005 21:40:00 11.4 0.5 12.6 9.9 11.4 0.5 12.6 9.9 57 3 56 305 1.2 0.2 1.5 1 05/27/2005 21:50:00 11.8 0.5 13 10.3 11.8 0.6 13 10.3 57 3 57 305 1.2 0.1 1.5 1 05/27/2005 22:00:00 11.9 0.5 13 10.7 11.9 0.5 13.3 10.3 55 3 56 305 1 0 1.5 0.8 05/27/2005 22:10:00 11.9 0.5 13.3 10.3 11.8 0.5 13 9.9 55 3 56 305 0.9 0.1 1.5 0.6 05/27/2005 22:20:00 12.3 0.6 13.7 10.3 12.3 0.6 13.7 9.9 57 3 65 305 0.9 0.1 1.3 0.6 05/27/2005 22:30:00 11.9 0.8 13.7 9.5 11.7 0.9 13.7 9.1 59 4 62 305 0.9 0.1 1.5 0.6 05/27/2005 22:40:00 12.7 0.7 14.5 10.7 12.6 0.8 14.5 10.7 61 3 62 305 1.1 0.1 1.5 0.8 05/27/2005 22:50:00 12 0.5 13.3 10.3 11.9 0.7 13.7 9.9 59 3 62 305 0.9 0.1 1.5 0.6 05/27/2005 23:00:00 11.9 0.5 13 10.3 11.9 0.6 13 9.9 57 3 62 305 0.8 0.1 1.3 0.6 05/27/2005 23:10:00 11.4 0.5 13 10.3 11.3 0.6 13 9.5 56 3 56 305 0.6 0.2 1 0.6 05/27/2005 23:20:00 11.5 0.4 12.6 10.3 11.4 0.5 13 9.9 58 3 71 305 0.7 0.2 1 0.6 05/27/2005 23:30:00 11.3 0.5 13 9.5 11.2 0.6 13 9.1 58 4 59 305 0.7 0.2 1.3 0.6 05/27/2005 23:40:00 11 0.5 12.2 9.9 11 0.6 12.6 9.1 58 4 58 305 0.9 0.2 1.3 0.6 05/27/2005 23:50:00 11.3 0.5 13 9.5 11.3 0.5 12.6 9.9 55 4 55 305 0.7 0.2 1 0.6 05/28/2005 00:00:00 10.9 0.5 12.6 9.5 11 0.5 12.2 9.5 54 3 46 305 0.6 0 1 0.3 05/28/2005 00:10:00 10.5 0.5 11.8 9.1 10.4 0.6 11.8 9.1 54 3 57 305 0.6 0 1 0.3 05/28/2005 00:20:00 10.3 0.5 11.5 8.8 10.3 0.5 11.8 8.8 55 3 56 305 0.6 0 1 0.6 05/28/2005 00:30:00 10.5 0.6 11.8 8.8 10.5 0.6 12.2 8.8 56 4 59 305 0.6 0 1 0.6 05/28/2005 00:40:00 10.1 0.8 12.2 8 10.1 0.7 11.8 8.4 54 5 51 305 0.6 0.1 1 0.6 05/28/2005 00:50:00 9.7 0.5 11.1 7.6 9.7 0.5 11.5 8.4 54 5 56 305 0.6 0 1 0.6 05/28/2005 01:00:00 10.2 0.5 11.5 8.8 10.3 0.6 12.2 8.8 53 4 53 305 0.6 0 1 0.6 05/28/2005 01:10:00 10.6 0.4 11.5 9.5 10.5 0.5 11.5 9.1 54 3 59 305 0.6 0 1 0.6 05/28/2005 01:20:00 10.6 0.4 11.8 9.1 10.6 0.5 11.8 9.1 54 3 53 305 0.6 0.1 1 0.6 05/28/2005 01:30:00 10.9 0.5 12.6 9.9 10.9 0.5 12.6 9.5 55 4 62 305 0.6 0.1 1 0.6 05/28/2005 01:40:00 11.2 0.5 12.6 9.9 11.2 0.6 12.6 9.5 55 3 50 305 0.5 0 1 0.6 05/28/2005 01:50:00 10.9 0.5 12.2 9.5 10.8 0.5 12.2 9.1 54 3 53 305 0.5 0 1 0.6 05/28/2005 02:00:00 10.6 0.5 11.8 9.1 10.6 0.6 11.8 8.4 55 3 54 305 0.5 0 1 0.3 05/28/2005 02:10:00 10.3 0.4 11.5 9.1 10.2 0.5 11.8 8.8 53 3 49 305 0.4 0 1 0.3 05/28/2005 02:20:00 9.9 0.5 11.1 8.4 9.9 0.5 11.1 8.4 53 4 57 305 0.4 0 0.8 0.3 05/28/2005 02:30:00 10 0.5 11.5 8.8 10 0.5 11.1 8 53 4 51 305 0.4 0 0.8 0.3 05/28/2005 02:40:00 10.9 0.8 13 8.8 10.8 0.9 13 8.4 50 4 47 305 0.4 0 0.8 0.3 05/28/2005 02:50:00 11.3 0.4 12.2 10.3 11.2 0.6 12.6 9.5 47 2 43 305 0.3 0 0.8 0.3 05/28/2005 03:00:00 11 0.3 12.2 9.9 10.9 0.4 11.8 9.5 49 2 48 305 0.3 0.1 0.8 0.1 05/28/2005 03:10:00 10.5 0.4 12.2 9.1 10.4 0.5 11.8 8.8 52 3 57 305 0.2 0.1 0.6 0.1 05/28/2005 03:20:00 10.4 0.4 11.8 9.1 10.3 0.5 11.8 8.8 50 3 52 305 0.1 0.1 0.6 0.1 05/28/2005 03:30:00 9.9 0.5 11.1 8 9.8 0.6 11.1 8 47 3 48 305 0 0 0.6 -0.1 05/28/2005 03:40:00 9.4 0.5 10.3 8 9.3 0.6 10.3 7.6 46 3 45 305 0 0.1 0.6 -0.1 05/28/2005 03:50:00 8.8 0.5 9.9 7.2 8.7 0.5 9.5 7.2 47 4 50 305 0 0.1 0.6 -0.1 05/28/2005 04:00:00 8.9 0.4 10.3 7.6 8.8 0.5 9.9 7.2 46 3 46 305 0 0.1 0.6 0.1 05/28/2005 04:10:00 9 0.4 10.3 8 8.9 0.4 9.9 7.6 43 3 41 305 0 0.1 0.6 -0.1 05/28/2005 04:20:00 9.3 0.5 10.3 8 9.2 0.6 10.3 7.6 42 3 40 305 0 0.1 0.6 -0.1 05/28/2005 04:30:00 9.1 0.4 10.3 8 9 0.5 9.9 7.2 44 3 40 305 0 0.1 0.6 -0.1 05/28/2005 04:40:00 8.8 0.4 9.5 7.6 8.6 0.4 9.5 7.6 44 3 44 305 0 0.1 0.6 -0.1 05/28/2005 04:50:00 9.3 0.5 10.3 8 9.1 0.5 10.3 7.6 43 3 41 305 0 0.1 0.6 0.1 05/28/2005 05:00:00 10.3 0.6 11.5 8.8 10.1 0.7 11.8 8.4 41 3 39 305 0 0.1 0.6 0.1 05/28/2005 05:10:00 10.4 0.4 11.1 9.1 10.3 0.5 11.5 8.4 43 2 37 305 0 0.1 0.6 -0.1 05/28/2005 05:20:00 10.1 0.5 11.1 8.8 10 0.5 11.5 8.4 42 3 43 305 0 0.1 0.6 0.1 05/28/2005 05:30:00 9.9 0.4 10.7 8.8 9.9 0.5 10.7 8.4 41 2 41 305 0 0.1 0.6 0.1 05/28/2005 05:40:00 10.3 0.4 11.5 9.1 10.3 0.4 11.5 9.1 40 2 38 305 0.1 0.1 0.6 0.1 05/28/2005 05:50:00 10.6 0.6 12.2 9.1 10.5 0.6 12.2 8.8 41 3 40 305 0.1 0.1 0.6 0.1 05/28/2005 06:00:00 11.1 0.5 12.6 9.9 10.9 0.7 13 9.1 42 3 37 305 0.2 0.1 0.6 0.1 05/28/2005 06:10:00 10.9 0.5 12.2 9.5 10.8 0.6 12.2 8.4 44 3 44 305 0.2 0.1 0.6 0.1 05/28/2005 06:20:00 11.3 0.5 12.6 9.9 11.2 0.5 12.6 9.1 42 3 38 305 0.1 0.1 0.6 0.1 05/28/2005 06:30:00 10.7 0.5 11.8 9.5 10.7 0.6 11.8 9.5 41 2 41 305 0 0.1 0.6 0.1 05/28/2005 06:40:00 10.4 0.5 11.8 9.1 10.3 0.5 11.8 8.8 37 3 35 305 0 0.1 0.6 0.1 05/28/2005 06:50:00 10.3 0.5 11.8 9.1 10.3 0.5 11.8 9.1 36 3 37 305 0 0.1 0.6 0.1 05/28/2005 07:00:00 10.2 0.6 11.5 8.8 10.1 0.7 11.5 8.4 35 3 30 305 0.2 0.1 0.6 0.1 05/28/2005 07:10:00 10.6 0.5 11.8 9.1 10.6 0.5 11.8 8.4 35 3 33 305 0.2 0.1 0.6 0.1 05/28/2005 07:20:00 10.1 0.4 11.5 8.8 10 0.5 11.1 8.4 37 3 42 305 0.2 0.1 0.6 0.1 05/28/2005 07:30:00 10.8 0.5 12.2 9.5 10.8 0.5 12.2 9.5 36 3 38 305 0.1 0.1 0.6 0.1 05/28/2005 07:40:00 11.2 0.4 12.2 9.9 11.2 0.5 12.2 9.5 39 2 39 305 0.1 0.1 0.6 0.1 05/28/2005 07:50:00 11 0.4 11.8 9.5 10.9 0.5 11.8 9.1 38 3 40 305 0.2 0.1 0.6 0.1 05/28/2005 08:00:00 11.3 0.5 12.2 9.9 11.3 0.5 12.6 9.5 38 2 39 305 0.2 0.1 0.8 0.1 05/28/2005 08:10:00 11.4 0.5 12.2 9.9 11.4 0.5 12.2 9.1 39 3 43 305 0.2 0.1 0.6 0.1 05/28/2005 08:20:00 11.1 0.4 11.8 9.5 11.1 0.5 12.2 9.5 38 2 40 305 0.2 0.1 0.8 0.1 05/28/2005 08:30:00 11.6 0.5 13 10.3 11.5 0.6 13 9.9 41 2 40 305 0.2 0.1 0.8 0.1 05/28/2005 08:40:00 11.8 0.6 13.3 10.3 11.5 0.7 13.3 9.5 42 3 41 305 0.2 0.2 0.8 0.1 05/28/2005 08:50:00 12 0.5 13.3 10.7 11.9 0.7 13.3 10.3 40 3 40 305 0.2 0.1 0.8 0.1 05/28/2005 09:00:00 11.4 0.5 12.6 10.3 11.3 0.6 13 9.9 38 3 40 305 0.3 0.1 0.8 0.1 05/28/2005 09:10:00 11.6 0.6 13 9.9 11.5 0.7 13 9.5 38 2 35 305 0.4 0 1 0.3 05/28/2005 09:20:00 12 0.6 13.3 10.3 12 0.6 13.3 9.5 38 2 40 305 0.5 0.1 1 0.3 05/28/2005 09:30:00 11.3 0.5 12.6 9.9 11.2 0.5 12.6 9.1 36 3 36 305 0.7 0.1 1.3 0.6 05/28/2005 09:40:00 11.6 0.5 12.6 9.9 11.5 0.6 13 9.5 35 3 35 305 0.6 0.1 1 0.3 05/28/2005 09:50:00 11.4 0.6 12.6 9.5 11.4 0.7 12.6 8.8 35 3 35 305 0.6 0.1 1.3 0.6 05/28/2005 10:00:00 11.6 0.5 12.6 9.5 11.5 0.7 13 9.5 37 3 35 305 0.8 0.1 1.3 0.6 05/28/2005 10:10:00 11.5 0.6 12.6 9.9 11.4 0.7 13 9.5 38 3 38 305 0.9 0.1 1.5 0.6 05/28/2005 10:20:00 11.4 0.5 12.6 10.3 11.3 0.5 12.6 9.5 41 3 40 305 1 0.1 1.5 0.8 05/28/2005 10:30:00 11.2 0.5 12.2 9.5 11.1 0.6 12.2 9.1 40 3 43 305 1.2 0.1 1.7 1 05/28/2005 10:40:00 11.4 0.6 13 9.5 11.4 0.7 13 9.1 40 3 42 305 1.3 0.2 2.2 1 05/28/2005 10:50:00 12.4 0.5 13.7 11.1 12.4 0.6 13.7 10.3 39 2 41 305 1.2 0.2 2 0.8 05/28/2005 11:00:00 11.7 0.5 13 9.9 11.7 0.5 12.6 10.3 40 3 42 305 0.8 0.1 1.3 0.6 05/28/2005 11:10:00 12 0.5 13 9.9 11.9 0.6 13 9.5 43 3 43 305 0.7 0.1 1.3 0.6 05/28/2005 11:20:00 12.1 0.6 13.3 10.3 12 0.6 13.3 10.3 42 3 40 305 0.7 0.1 1.3 0.6 05/28/2005 11:30:00 12.2 0.6 13.7 10.7 12.1 0.7 14.1 9.9 43 3 46 305 0.7 0 1.3 0.6 05/28/2005 11:40:00 12.1 0.6 13.7 10.7 12 0.8 13.7 9.9 43 3 44 305 0.9 0 1.3 0.6 05/28/2005 11:50:00 12.4 0.6 13.7 10.3 12.4 0.7 13.7 10.3 40 3 36 305 0.8 0 1.3 0.6 05/28/2005 12:00:00 12.9 0.5 14.1 11.5 12.9 0.6 14.1 10.7 41 3 38 305 0.9 0 1.5 0.6 05/28/2005 12:10:00 13.1 0.5 14.1 11.5 13.1 0.6 14.5 11.5 39 2 38 305 1 0.1 1.5 0.6 05/28/2005 12:20:00 13 0.5 14.5 11.5 12.9 0.6 14.5 10.7 41 3 41 305 1 0.1 1.5 0.6 05/28/2005 12:30:00 13.3 0.5 14.5 11.5 13.2 0.6 14.5 10.3 41 2 37 305 0.9 0.1 1.3 0.6 05/28/2005 12:40:00 13.2 0.5 14.1 11.1 13.1 0.6 14.1 10.3 42 3 46 305 1 0.1 1.5 0.8 05/28/2005 12:50:00 12.9 0.6 14.5 10.7 12.8 0.8 14.5 9.9 40 3 41 305 1.1 0 1.5 1 05/28/2005 13:00:00 13.1 0.7 14.5 11.5 12.9 0.8 14.5 10.3 40 3 35 305 1.2 0.1 1.5 1 05/28/2005 13:10:00 12 0.8 13.3 9.5 11.8 0.9 13.3 9.1 37 4 39 305 1.2 0.1 1.5 0.8 05/28/2005 13:20:00 12.4 0.5 13.3 10.7 12.3 0.6 13.7 10.3 36 3 35 305 1.1 0.1 1.5 0.8 05/28/2005 13:30:00 11.7 0.9 13 8.8 11.6 1 13 8.8 36 3 38 305 1 0.2 1.5 0.6 05/28/2005 13:40:00 11.6 0.7 13 9.1 11.5 0.9 13 8.8 36 3 36 305 1 0.1 1.5 0.6 05/28/2005 13:50:00 11.6 0.6 13.3 9.9 11.6 0.7 13 9.5 35 3 31 305 0.9 0.1 1.5 0.6 05/28/2005 14:00:00 12.1 0.5 13.3 10.3 12.1 0.6 13.3 9.5 37 3 39 305 1 0.1 1.5 0.8 05/28/2005 14:10:00 12 0.6 14.1 10.7 11.9 0.8 13.7 9.5 36 3 39 305 1.1 0.2 1.5 0.6 05/28/2005 14:20:00 11.6 0.6 13 9.1 11.5 0.8 13 8.8 38 3 38 305 1.3 0.1 1.7 1 05/28/2005 14:30:00 11.7 0.6 13 9.9 11.5 0.7 13 9.1 36 3 36 305 1.3 0.1 2 1 05/28/2005 14:40:00 12.1 0.5 13.3 10.7 12 0.7 13 9.1 37 3 35 305 1.6 0.1 2.2 1.3 05/28/2005 14:50:00 11.9 0.7 13.3 9.5 11.7 0.8 13.7 9.5 36 3 43 305 1.7 0.1 2.2 1.5 05/28/2005 15:00:00 11.8 0.6 13.3 9.5 11.7 0.8 13.3 8.8 36 3 39 305 1.4 0.2 2.2 0.8 05/28/2005 15:10:00 12 0.6 13.3 10.3 11.9 0.7 13.3 9.9 38 3 36 305 1.2 0.2 1.5 1 05/28/2005 15:20:00 12.3 0.7 13.7 10.7 12.2 0.9 13.7 9.5 39 3 40 305 1.2 0.1 1.7 0.8 05/28/2005 15:30:00 11.9 0.6 13 10.3 11.8 0.8 13.3 9.5 41 3 43 305 1 0.2 1.7 0.6 05/28/2005 15:40:00 11.9 0.6 13.3 10.3 11.9 0.7 13.3 9.5 40 3 38 305 1.3 0.2 2 1 05/28/2005 15:50:00 12.1 0.5 13.3 10.7 11.9 0.6 13.3 9.1 41 3 41 305 1.5 0.1 2.2 1.3 05/28/2005 16:00:00 12.4 0.6 13.7 10.7 12.1 0.7 13.7 9.5 42 3 45 305 1.4 0.1 2 1.3 05/28/2005 16:10:00 12.2 0.6 13.7 9.9 12 0.9 13.7 8.8 43 3 42 305 1.2 0.1 1.7 0.8 05/28/2005 16:20:00 12.2 0.5 13.3 10.3 11.9 0.8 13.3 9.5 44 3 41 305 1 0.1 1.5 0.8 05/28/2005 16:30:00 11.6 0.5 13 9.9 11.4 0.7 13 9.5 41 3 45 305 0.9 0.1 1.5 0.8 05/28/2005 16:40:00 12.1 0.6 13.7 9.9 11.9 0.8 13.3 9.1 46 3 45 305 0.9 0.1 1.5 0.6 05/28/2005 16:50:00 12.6 0.6 13.7 9.9 12.5 0.7 13.7 9.1 48 2 48 305 0.8 0.1 1.3 0.6 05/28/2005 17:00:00 12.6 0.6 13.7 10.3 12.4 0.7 13.7 9.9 47 3 46 305 1 0.1 1.7 0.6 05/28/2005 17:10:00 12.7 0.6 14.1 10.3 12.5 0.8 13.7 9.9 49 3 51 305 1.2 0.1 2 1 05/28/2005 17:20:00 12.2 0.6 13.3 10.7 11.8 0.8 13.3 9.9 48 3 48 305 1.4 0.2 2.2 1 05/28/2005 17:30:00 12 0.6 13 9.1 11.8 0.9 13 9.1 45 3 44 305 1.4 0.2 2 1 05/28/2005 17:40:00 12.8 0.4 13.7 11.1 12.6 0.6 13.7 10.7 45 3 45 305 1.2 0.2 1.7 0.8 05/28/2005 17:50:00 12.6 0.4 13.7 10.3 12.4 0.6 13.7 9.5 49 3 48 305 1.3 0.2 1.7 1 05/28/2005 18:00:00 12.2 0.6 13.3 10.3 12 0.8 13.3 9.9 51 3 51 305 1.5 0.1 2.2 1 05/28/2005 18:10:00 12.3 0.4 13.3 11.1 12.1 0.6 13.7 9.9 51 3 54 305 1.6 0 2 1.3 05/28/2005 18:20:00 11.8 0.5 13 9.9 11.6 0.7 13 9.5 48 3 45 305 1.5 0 2 1.3 05/28/2005 18:30:00 12 0.5 13 10.7 11.7 0.7 13.3 9.5 45 3 43 305 1.5 0 2 1.3 05/28/2005 18:40:00 11.8 0.6 13.3 9.9 11.6 0.7 13.3 9.5 46 4 45 305 1.2 0.1 1.7 0.8 05/28/2005 18:50:00 11.4 0.5 12.6 9.9 11.3 0.6 12.6 8.8 44 3 41 305 0.9 0.1 1.5 0.6 05/28/2005 19:00:00 11.4 0.5 13 9.1 11.2 0.7 12.6 8.4 47 3 44 305 1 0.1 1.5 0.6 05/28/2005 19:10:00 11.3 0.5 12.6 9.5 11.1 0.7 12.2 9.1 46 3 47 305 1.2 0.2 2 1 05/28/2005 19:20:00 11.2 0.5 12.6 9.1 11 0.7 12.6 8.4 46 3 46 305 1.1 0.2 1.5 0.8 05/28/2005 19:30:00 11.4 0.5 12.6 9.1 11.3 0.7 13 9.1 46 3 43 305 1.1 0.2 1.5 0.8 05/28/2005 19:40:00 11.2 0.5 12.2 9.5 11 0.7 12.2 8 48 3 47 305 1.2 0.1 1.5 0.8 05/28/2005 19:50:00 11.6 0.5 12.6 9.9 11.4 0.6 12.2 9.5 50 3 48 305 1.1 0.1 1.5 0.8 05/28/2005 20:00:00 11 0.6 12.2 8.8 10.8 0.7 12.2 8 50 4 50 305 1 0.1 1.5 0.8 05/28/2005 20:10:00 10.6 0.5 11.8 9.1 10.5 0.6 11.8 8.8 48 3 52 305 0.9 0.1 1.3 0.6 05/28/2005 20:20:00 10.4 0.7 12.2 8.4 10.2 0.8 12.2 8 48 3 44 305 0.9 0 1.5 0.8 05/28/2005 20:30:00 11.3 0.5 12.2 9.5 11.1 0.7 12.2 8.8 50 3 49 305 0.7 0.2 1.3 0.6 05/28/2005 20:40:00 11 0.5 12.2 9.1 10.7 0.7 12.2 8.8 50 3 47 305 0.9 0 1.5 0.6 05/28/2005 20:50:00 11.5 0.4 12.2 9.9 11.3 0.5 12.6 9.1 52 2 54 305 0.7 0.1 1.3 0.6 05/28/2005 21:00:00 11.2 0.5 12.6 9.5 11.1 0.6 12.2 8.8 52 3 51 305 0.6 0.1 1.3 0.6 05/28/2005 21:10:00 11.1 0.5 12.2 9.1 10.8 0.8 12.2 8.8 49 3 46 305 0.8 0.1 1.5 0.6 05/28/2005 21:20:00 11.6 0.5 12.6 9.9 11.4 0.7 12.6 8.8 51 3 52 305 0.7 0.2 1.5 0.6 05/28/2005 21:30:00 12 0.4 13 10.3 11.8 0.6 13 9.9 54 3 56 305 0.6 0.1 1 0.6 05/28/2005 21:40:00 12.1 0.5 13.3 10.7 12 0.5 13.3 9.9 53 2 51 305 0.4 0 1 0.3 05/28/2005 21:50:00 12.2 0.7 13.3 9.1 12 0.8 13.3 8.8 54 2 57 305 0.5 0 0.8 0.3 05/28/2005 22:00:00 12.4 0.6 13.3 9.9 12.2 0.7 13.7 9.5 56 2 58 305 0.5 0 1 0.3 05/28/2005 22:10:00 12.4 0.4 13.3 11.1 12.2 0.6 13.3 10.3 56 2 59 305 0.4 0 0.8 0.3 05/28/2005 22:20:00 12 0.4 13 10.3 11.9 0.5 13 9.9 55 2 57 305 0.4 0 0.8 0.3 05/28/2005 22:30:00 12.1 0.5 13.3 10.7 11.9 0.6 13 9.5 55 2 54 305 0.4 0 0.8 0.3 05/28/2005 22:40:00 11.8 0.5 12.6 10.3 11.6 0.6 13 9.5 57 3 57 305 0.4 0 0.8 0.3 05/28/2005 22:50:00 12 0.5 13.3 10.3 11.7 0.7 13.3 9.1 56 3 62 305 0.4 0 0.8 0.3 05/28/2005 23:00:00 12.4 0.3 13.3 10.7 12.3 0.5 13.7 10.7 57 2 60 305 0.3 0 0.8 0.3 05/28/2005 23:10:00 12 0.5 13 9.9 11.8 0.6 13.3 9.5 56 2 58 305 0.3 0 0.8 0.3 05/28/2005 23:20:00 12.1 0.4 13 10.7 11.9 0.4 12.6 10.3 55 2 56 305 0.3 0 0.8 0.1 05/28/2005 23:30:00 11.7 0.4 12.6 10.7 11.6 0.5 12.6 9.5 52 2 54 305 0.3 0 0.6 0.1 05/28/2005 23:40:00 11.3 0.5 12.6 9.5 11.1 0.6 12.6 8.8 50 3 47 305 0.3 0 0.8 0.1 05/28/2005 23:50:00 11.6 0.4 12.6 10.3 11.3 0.5 12.6 9.9 51 3 48 305 0.3 0 0.6 0.1 05/29/2005 00:00:00 11.8 0.4 13 10.3 11.7 0.5 13 9.9 52 3 51 305 0.3 0 0.6 0.1 05/29/2005 00:10:00 12.2 0.4 13 11.1 12.1 0.4 13.3 10.3 53 2 56 305 0.2 0 0.6 0.1 05/29/2005 00:20:00 12.1 0.4 13 10.3 12 0.5 13.3 9.5 53 3 54 305 0.2 0 0.6 0.1 05/29/2005 00:30:00 12.5 0.4 13.7 11.5 12.4 0.5 13.7 10.7 54 3 48 305 0.2 0 0.6 0.1 05/29/2005 00:40:00 13.1 0.5 14.1 11.1 13 0.7 14.5 11.1 55 2 53 305 0.2 0 0.6 0.1 05/29/2005 00:50:00 12.7 0.5 13.7 10.7 12.7 0.5 14.5 11.1 56 2 58 305 0.2 0 0.8 0.1 05/29/2005 01:00:00 12.2 0.5 13 10.7 12.2 0.6 13.7 9.5 55 2 58 305 0.2 0 0.6 0.1 05/29/2005 01:10:00 12.1 0.5 13.3 10.3 12 0.5 13.3 10.3 55 3 53 305 0.2 0 0.6 0.1 05/29/2005 01:20:00 11.8 0.4 13 10.7 11.9 0.5 13 9.9 54 3 58 305 0.1 0 0.6 0.1 05/29/2005 01:30:00 11.4 0.4 12.2 9.9 11.4 0.5 12.6 9.5 52 3 50 305 0.1 0.1 0.6 0.1 05/29/2005 01:40:00 11 0.5 12.6 9.5 11 0.6 13 9.1 50 4 53 305 0.1 0 0.6 0.1 05/29/2005 01:50:00 11.2 0.4 12.2 9.9 11.2 0.5 12.6 9.5 50 3 51 305 0.1 0.1 0.6 0.1 05/29/2005 02:00:00 11.3 0.5 12.6 9.9 11.3 0.5 12.6 9.1 48 4 49 305 0.1 0.1 0.6 0.1 05/29/2005 02:10:00 10.6 0.5 11.8 9.1 10.6 0.6 11.8 8.8 49 4 49 305 0.1 0 0.6 0.1 05/29/2005 02:20:00 10.8 0.6 11.8 9.1 10.7 0.6 11.8 8.8 47 4 41 305 0.1 0.1 0.6 0.1 05/29/2005 02:30:00 10.7 0.5 12.2 9.1 10.6 0.6 11.8 8.8 50 4 50 305 0 0 0.6 0.1 05/29/2005 02:40:00 10.2 0.7 11.8 8 9.9 0.7 11.8 8 48 4 48 305 0.1 0.1 0.6 0.1 05/29/2005 02:50:00 9.7 0.6 11.8 8 9.6 0.7 11.5 7.2 49 6 48 305 0 0.1 0.6 0.1 05/29/2005 03:00:00 10.1 0.6 12.2 8.4 10 0.6 11.5 8 46 5 47 305 0 0 0.6 0.1 05/29/2005 03:10:00 10.7 0.7 12.6 8.8 10.7 0.7 13 8.8 48 5 54 305 0 0.1 0.6 0.1 05/29/2005 03:20:00 10.4 0.6 12.2 8.8 10.4 0.6 11.8 8.4 48 5 44 305 0 0.1 0.6 0.1 05/29/2005 03:30:00 9.9 0.6 11.1 8 9.7 0.6 11.5 8 45 5 41 305 0.1 0.1 0.6 0.1 05/29/2005 03:40:00 10 0.6 11.5 8 9.9 0.6 11.1 8 43 4 50 305 0.1 0.1 0.6 0.1 05/29/2005 03:50:00 10.1 0.5 11.1 8.4 10.1 0.5 11.5 8.4 43 4 36 305 0.1 0.1 0.6 0.1 05/29/2005 04:00:00 10.2 0.8 12.2 8 10.1 0.9 11.8 7.6 48 5 47 305 0.2 0.1 0.6 0.1 05/29/2005 04:10:00 10.8 0.5 12.6 9.5 10.9 0.5 12.6 9.5 49 4 45 305 0.1 0.1 0.6 0.1 05/29/2005 04:20:00 10.4 0.7 12.2 8 10.5 0.6 12.2 8.8 49 6 55 305 0.2 0.1 0.6 0.1 05/29/2005 04:30:00 10.4 0.7 12.2 8.4 10.5 0.7 12.2 8.4 50 5 54 305 0.2 0.1 0.6 0.1 05/29/2005 04:40:00 10.2 0.6 11.8 8.8 10.3 0.7 12.6 8.4 51 6 54 305 0.2 0.1 0.6 0.1 05/29/2005 04:50:00 11.1 0.7 13.3 8.8 11.1 0.7 13 9.1 50 5 57 305 0.3 0 0.6 0.1 05/29/2005 05:00:00 11.3 0.6 13.7 9.5 11.3 0.7 13.3 9.1 50 4 48 305 0.3 0 0.6 0.3 05/29/2005 05:10:00 11.2 0.5 12.6 9.5 11.1 0.6 12.6 9.1 50 4 51 305 0.3 0 0.6 0.1 05/29/2005 05:20:00 10.6 0.6 11.8 9.1 10.6 0.7 12.2 8.8 50 4 51 305 0.2 0 0.6 0.1 05/29/2005 05:30:00 10.4 0.5 12.2 8.8 10.5 0.6 12.2 8.8 51 4 48 305 0.3 0 0.3 0.1 05/29/2005 05:40:00 10.1 0.6 11.5 8.4 9.9 0.6 11.8 8.4 48 5 48 305 0.2 0 0.6 0.1 05/29/2005 05:50:00 9.9 0.6 11.5 8.4 9.7 0.6 11.1 8 46 5 47 305 0.2 0 0.6 0.1 05/29/2005 06:00:00 9.9 0.5 11.1 8.4 9.8 0.5 11.1 8 45 5 44 305 0.2 0 0.6 0.1 05/29/2005 06:10:00 10.5 0.7 12.2 8.8 10.4 0.7 11.8 8.8 49 4 50 305 0.1 0 0.6 0.1 05/29/2005 06:20:00 11.3 0.6 13 9.5 11.2 0.7 12.6 9.1 49 4 50 305 0.1 0 0.3 0.1 05/29/2005 06:30:00 10.6 0.6 12.6 8.8 10.4 0.7 12.2 8.4 46 4 44 305 0.1 0 0.3 0.1 05/29/2005 06:40:00 10.4 0.4 11.5 8.8 10.3 0.5 11.5 8.8 44 3 46 305 0.1 0 0.3 0.1 05/29/2005 06:50:00 10 0.6 11.5 8.4 9.8 0.7 11.5 8 47 5 44 305 0 0 0.3 0.1 05/29/2005 07:00:00 9.3 0.6 11.1 7.6 9.1 0.7 11.1 7.2 48 5 49 305 0 0 0.3 -0.1 05/29/2005 07:10:00 10.4 0.6 11.8 8.8 10.4 0.6 11.8 8.8 50 5 48 305 0.2 0.1 0.6 0.1 05/29/2005 07:20:00 10.9 0.6 12.6 8.8 10.9 0.7 13.3 8.8 52 5 43 305 0.3 0 0.6 0.1 05/29/2005 07:30:00 10.5 0.9 12.6 8.8 10.4 1 13 8.4 49 5 58 305 0.4 0 0.8 0.3 05/29/2005 07:40:00 10.8 1 13.3 9.1 10.7 1.1 13 8.8 51 6 56 305 0.5 0 1 0.3 05/29/2005 07:50:00 11 0.8 13 8.8 10.8 1 13 8.4 49 6 59 305 0.6 0 1 0.6 05/29/2005 08:00:00 11.5 0.8 13.7 9.5 11.5 0.9 13.3 8.8 52 6 48 305 0.6 0 1 0.6 05/29/2005 08:10:00 11.3 0.6 13 9.5 11.3 0.7 13 9.1 52 5 61 305 0.6 0 1 0.6 05/29/2005 08:20:00 11.5 0.5 13 9.9 11.4 0.6 13 9.9 51 5 50 305 0.7 0 1.3 0.6 05/29/2005 08:30:00 11.5 0.5 13 10.3 11.5 0.6 13 9.5 51 5 61 305 0.7 0.1 1.3 0.6 05/29/2005 08:40:00 10.6 0.7 12.2 9.1 10.4 0.8 12.2 8 48 4 53 305 0.7 0.1 1.3 0.6 05/29/2005 08:50:00 10.3 0.6 11.8 8.8 10.1 0.6 11.5 8.4 47 5 53 305 0.6 0.1 1.3 0.6 05/29/2005 09:00:00 10.1 0.5 11.5 8 10.1 0.6 11.5 8.4 53 4 50 305 0.6 0 1.3 0.6 05/29/2005 09:10:00 10.6 0.4 11.8 9.5 10.6 0.5 11.8 9.1 52 4 55 305 0.6 0.1 1.3 0.6 05/29/2005 09:20:00 10.3 0.5 11.8 8.8 10.3 0.6 12.2 8.8 50 4 50 305 0.7 0.1 1.3 0.6 05/29/2005 09:30:00 9.4 0.4 10.3 7.6 9.3 0.5 10.3 7.2 40 5 54 305 0.7 0.2 1.3 0.6 05/29/2005 09:40:00 10.1 0.5 11.5 8.8 10.1 0.6 11.5 8.8 42 3 45 305 0.5 0 1 0.3 05/29/2005 09:50:00 10.5 0.4 11.8 9.1 10.5 0.5 11.5 8.8 43 3 39 305 0.5 0 1 0.3 05/29/2005 10:00:00 10.3 0.5 11.8 8.8 10.3 0.6 11.5 8.8 48 4 47 305 0.5 0 0.8 0.3 05/29/2005 10:10:00 10.4 0.6 11.8 8.4 10.5 0.6 11.8 8.8 51 4 48 305 0.6 0 1.3 0.6 05/29/2005 10:20:00 10.9 0.5 12.2 9.9 11 0.5 13 9.9 49 4 48 305 0.5 0 0.8 0.3 05/29/2005 10:30:00 10.6 0.5 11.8 9.1 10.5 0.6 11.8 8.4 48 5 50 305 0.5 0 1 0.6 05/29/2005 10:40:00 10.9 0.5 12.2 9.1 10.8 0.5 12.2 8.8 48 4 47 305 0.6 0 1 0.3 05/29/2005 10:50:00 10.4 0.5 11.5 9.1 10.4 0.5 11.5 8.8 50 4 45 305 0.5 0 1 0.3 05/29/2005 11:00:00 11 0.4 12.2 9.9 11.1 0.5 12.2 9.9 52 3 50 305 0.5 0 1.3 0.3 05/29/2005 11:10:00 11 0.5 12.2 9.1 10.9 0.6 12.2 9.1 51 3 53 305 0.7 0.1 1.3 0.6 05/29/2005 11:20:00 11.3 0.5 12.6 9.1 11.2 0.6 12.6 9.1 49 3 46 305 0.6 0.1 1.3 0.6 05/29/2005 11:30:00 11 0.6 12.2 9.1 10.9 0.7 12.2 8.8 52 3 57 305 0.7 0.1 1.5 0.6 05/29/2005 11:40:00 9.9 0.8 11.5 7.2 9.7 0.9 11.5 7.2 50 4 54 305 1 0 1.5 0.8 05/29/2005 11:50:00 9.9 0.7 11.1 7.2 9.6 0.8 11.1 6.8 51 4 48 305 1.2 0.1 1.7 1 05/29/2005 12:00:00 8.6 0.8 10.3 6.5 8.3 0.9 10.7 6.1 48 6 51 305 1.3 0.1 1.7 1 05/29/2005 12:10:00 7.9 0.9 9.9 5.3 7.6 1 9.5 4.9 48 6 48 305 1.4 0.1 2 1 05/29/2005 12:20:00 7.1 1.1 9.1 4.6 6.7 1.1 9.1 3.8 46 7 51 305 1.6 0.1 2.2 1.3 05/29/2005 12:30:00 5.8 0.8 7.6 3.8 5.6 0.9 7.6 3.8 38 7 40 305 1.3 0.1 1.7 1 05/29/2005 12:40:00 5 0.6 6.5 3.8 4.8 0.5 6.5 3.4 28 6 22 305 1.3 0.1 1.5 1 05/29/2005 12:50:00 6.8 1 8.4 4.2 6.7 1 8.4 3.8 37 5 41 305 1.2 0.1 1.5 0.8 05/29/2005 13:00:00 7.9 0.5 8.8 6.5 7.7 0.6 9.1 6.1 48 4 42 305 1.4 0.2 2 1 05/29/2005 13:10:00 7 0.6 9.1 5.3 6.9 0.7 8.4 4.9 51 6 56 305 1.7 0.2 2.5 1.3 05/29/2005 13:20:00 6.9 0.6 8.4 5.3 6.7 0.6 8.4 4.9 47 5 57 305 2 0.2 2.7 1.5 05/29/2005 13:30:00 8 0.7 9.5 5.7 7.9 0.7 9.1 5.7 50 5 52 305 2 0.2 2.7 1.7 05/29/2005 13:40:00 7.9 0.4 8.8 6.5 8 0.5 8.8 5.7 56 3 55 305 1.9 0.2 2.5 1.5 05/29/2005 13:50:00 7.5 0.5 8.8 6.5 7.5 0.6 9.1 5.7 55 4 57 305 1.6 0.1 2.2 1.3 05/29/2005 14:00:00 7.1 0.5 8.4 5.7 7.1 0.5 8 5.3 53 3 53 305 1.6 0.1 2.2 1.3 05/29/2005 14:10:00 7 0.5 8.4 5.7 6.9 0.5 8 4.9 54 4 45 305 1.8 0.2 2.5 1.3 05/29/2005 14:20:00 7.4 0.5 8.4 5.7 7.2 0.6 8.4 5.7 55 4 57 305 2 0.2 2.5 1.7 05/29/2005 14:30:00 7.1 0.5 8 5.7 7.1 0.5 8 5.7 42 7 53 305 2 0.1 2.7 1.7 05/29/2005 14:40:00 6.9 0.6 8 5.7 6.9 0.6 8.8 4.9 43 8 49 305 1.9 0.1 2.5 1.7 05/29/2005 14:50:00 6.6 0.6 8.4 5.3 6.6 0.7 8.4 4.9 41 9 46 305 2.1 0.2 2.7 1.5 05/29/2005 15:00:00 6.6 0.4 7.6 4.9 6.5 0.5 7.6 4.9 36 5 34 305 1.9 0.2 2.7 1.5 05/29/2005 15:10:00 6.9 0.6 8.4 5.3 6.7 0.6 8 5.3 35 4 40 305 1.9 0.2 2.5 1.5 05/29/2005 15:20:00 7.1 0.5 8.8 6.1 6.9 0.6 8.8 5.7 40 4 41 305 1.7 0.2 2.2 1.3 05/29/2005 15:30:00 6.8 0.6 8.4 5.3 6.5 0.8 8 4.9 45 4 46 305 1.5 0.2 2.2 1.3 05/29/2005 15:40:00 6.4 0.4 7.6 4.9 6.3 0.5 7.6 4.9 44 5 45 305 1.4 0.2 2 1 05/29/2005 15:50:00 6.2 0.4 7.6 5.3 6.2 0.5 7.2 5.3 41 5 41 305 1.2 0.1 1.5 1 05/29/2005 16:00:00 6.3 0.5 7.6 5.3 6.4 0.5 7.6 4.9 41 5 54 305 1.3 0.2 2 1 05/29/2005 16:10:00 6.9 0.4 8 5.7 6.9 0.4 8 6.1 38 3 37 305 1.3 0.2 2 1 05/29/2005 16:20:00 6.1 0.6 7.6 4.6 6.1 0.6 7.6 4.9 29 5 36 305 1.3 0.2 2 1 05/29/2005 16:30:00 6.8 0.4 7.6 5.7 6.8 0.5 8 5.3 38 6 33 305 1 0.1 1.5 0.8 05/29/2005 16:40:00 6.1 0.4 6.8 4.9 6.2 0.4 7.2 5.3 44 4 48 305 1.2 0.1 1.5 0.8 05/29/2005 16:50:00 6.6 0.4 8 5.3 6.6 0.4 7.6 5.3 46 4 48 305 1 0.2 1.5 0.6 05/29/2005 17:00:00 6.1 0.4 7.2 4.9 6.1 0.4 7.2 4.9 41 7 47 305 1.1 0.2 1.5 0.8 05/29/2005 17:10:00 6.8 0.7 8.4 4.2 6.9 0.9 8.8 4.2 44 6 43 305 1.3 0.2 2 1 05/29/2005 17:20:00 7.2 0.9 9.1 3.8 7.3 0.8 8.8 4.2 50 7 69 305 1.1 0.1 1.5 0.8 05/29/2005 17:30:00 6 1.2 8.8 3 6.2 1.1 8.8 3 45 9 43 305 1 0.2 1.5 0.6 05/29/2005 17:40:00 4.5 0.6 6.1 2.6 4.9 0.5 6.5 3.4 29 12 52 305 0.7 0.2 1.3 0.6 05/29/2005 17:50:00 5.1 0.5 6.5 3.4 5.1 0.5 6.5 3.4 30 3 36 305 0.6 0.2 1.3 0.3 05/29/2005 18:00:00 5.1 0.6 6.1 3.8 5.1 0.6 6.1 3.4 25 10 25 305 0.5 0 0.8 0.3 05/29/2005 18:10:00 5.9 0.4 6.8 4.2 5.9 0.5 6.8 3.8 33 4 36 305 0.5 0 1 0.3 05/29/2005 18:20:00 6.6 0.5 8 4.9 6.7 0.5 8 5.3 37 5 41 305 0.5 0 1 0.3 05/29/2005 18:30:00 6.3 0.5 7.6 4.9 6.3 0.5 7.6 4.9 36 5 41 305 0.6 0 1 0.3 05/29/2005 18:40:00 5.8 0.3 6.5 4.9 5.8 0.3 6.5 4.9 34 3 35 305 0.9 0 1.3 0.6 05/29/2005 18:50:00 5.3 0.5 6.1 3.8 5.3 0.5 6.5 3.8 30 6 35 305 1 0.1 1.5 0.8 05/29/2005 19:00:00 4.5 0.2 4.9 3.8 4.5 0.3 5.3 3.8 25 6 17 305 0.9 0.1 1.5 0.6 05/29/2005 19:10:00 4.9 0.4 5.7 4.2 4.9 0.4 5.7 3.8 34 2 33 305 0.6 0.1 1.3 0.6 05/29/2005 19:20:00 4.6 0.5 5.7 2.3 4.6 0.6 5.7 2.6 36 6 35 305 0.7 0.1 1.3 0.6 05/29/2005 19:30:00 4.2 0.6 5.3 2.6 4.1 0.6 5.7 2.3 39 9 36 305 1.1 0.2 1.5 0.6 05/29/2005 19:40:00 4.9 0.4 5.7 3.8 4.7 0.5 5.7 3.4 37 5 33 305 1.2 0.1 1.7 1 05/29/2005 19:50:00 4.4 0.4 5.3 3.4 4.3 0.4 5.3 3 27 5 33 305 1 0.1 1.5 0.8 05/29/2005 20:00:00 4.1 0.3 4.9 3 4 0.4 4.9 2.6 29 8 21 305 0.9 0 1.5 0.6 05/29/2005 20:10:00 4.9 0.3 5.7 4.2 5 0.3 5.7 3.8 35 2 35 305 0.9 0 1.3 0.8 05/29/2005 20:20:00 4.8 0.3 5.3 4.2 4.8 0.4 5.7 4.2 33 3 39 305 0.8 0 1 0.6 05/29/2005 20:30:00 4.6 0.2 4.9 3.8 4.5 0.2 4.9 3.8 33 2 32 305 0.7 0 1 0.6 05/29/2005 20:40:00 4.1 0.4 4.9 3 4.1 0.4 4.9 3.4 34 4 32 305 0.7 0 1.3 0.6 05/29/2005 20:50:00 4.5 0.7 6.1 3.4 4.4 0.7 6.1 3.4 27 3 21 305 0.9 0 1.5 0.8 05/29/2005 21:00:00 4.8 0.4 6.1 3.8 4.7 0.4 5.7 3.8 25 4 22 305 1 0 1.5 0.8 05/29/2005 21:10:00 4.5 0.4 5.3 3.8 4.5 0.4 5.3 3.4 21 3 16 305 1 0 1.3 0.8 05/29/2005 21:20:00 4.4 0.3 5.3 3.8 4.3 0.3 5.3 3.4 24 4 19 305 0.9 0 1.5 0.8 05/29/2005 21:30:00 4.6 0.3 5.3 3.8 4.4 0.3 5.3 3.4 30 3 26 305 1 0 1.5 0.8 05/29/2005 21:40:00 4.8 0.3 5.3 3.8 4.8 0.3 5.3 3.8 25 3 25 305 1 0 1.5 0.8 05/29/2005 21:50:00 5 0.3 5.7 4.2 5.1 0.3 5.7 4.2 22 2 23 305 0.9 0 1.3 0.8 05/29/2005 22:00:00 4.8 0.3 5.3 4.2 4.7 0.3 5.3 4.2 23 2 22 305 0.9 0 1.3 0.8 05/29/2005 22:10:00 4.5 0.2 4.9 3.8 4.5 0.3 4.9 3.8 25 3 30 305 0.8 0 1.3 0.8 05/29/2005 22:20:00 4.5 0.2 5.3 3.8 4.5 0.3 5.3 3.8 26 2 24 305 0.8 0 1.3 0.6 05/29/2005 22:30:00 4.6 0.3 5.7 3.8 4.6 0.3 5.3 3.8 27 3 32 305 0.7 0 1.3 0.6 05/29/2005 22:40:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 4.2 27 3 23 305 0.7 0 1.3 0.6 05/29/2005 22:50:00 5.2 0.5 6.1 4.2 5.2 0.5 6.1 4.2 30 3 27 305 0.7 0 1 0.6 05/29/2005 23:00:00 5 0.3 5.7 3.8 5 0.3 5.7 3.8 31 2 31 305 0.6 0.1 1.3 0.6 05/29/2005 23:10:00 4.7 0.4 5.7 3.8 4.7 0.4 5.7 3.4 25 3 25 305 0.6 0.1 1 0.6 05/29/2005 23:20:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.8 26 4 26 305 0.6 0.1 1 0.6 05/29/2005 23:30:00 4.3 0.4 4.9 3.4 4.3 0.4 4.9 3 27 4 27 305 0.6 0 1 0.3 05/29/2005 23:40:00 4.9 0.3 5.7 3.8 5 0.4 5.7 3.4 24 4 20 305 0.4 0.1 1 0.1 05/29/2005 23:50:00 4.9 0.3 5.7 4.2 5 0.3 5.7 4.2 31 3 30 305 0.2 0.1 0.6 0.1 05/30/2005 00:00:00 4.7 0.4 5.7 3.8 4.8 0.4 5.7 3.8 34 3 36 305 0.1 0 0.6 0.1 05/30/2005 00:10:00 5.4 0.3 5.7 4.6 5.5 0.3 6.1 4.6 32 2 40 305 0 0 0.1 -0.1 05/30/2005 00:20:00 5.1 0.3 5.7 4.6 5.2 0.3 6.1 4.6 35 2 36 305 0 0 0.6 0.1 05/30/2005 00:30:00 5.6 0.3 6.1 4.9 5.8 0.3 6.5 4.9 32 2 31 305 0.1 0.1 0.6 0.1 05/30/2005 00:40:00 5.7 0.4 6.5 4.9 5.9 0.4 6.8 4.9 34 3 34 305 0.1 0 0.6 0.1 05/30/2005 00:50:00 6 0.4 6.8 4.9 6 0.5 6.8 4.9 34 2 35 305 0.2 0 0.6 0.1 05/30/2005 01:00:00 5.6 0.3 6.5 4.6 5.7 0.4 6.5 4.6 36 2 39 305 0.2 0 0.3 0.1 05/30/2005 01:10:00 5.9 0.3 6.5 4.6 6 0.4 6.8 4.9 39 3 37 305 0.2 0 0.6 0.1 05/30/2005 01:20:00 6.1 0.5 7.2 4.9 6.2 0.5 7.6 4.9 39 4 36 305 0.2 0 0.8 0.1 05/30/2005 01:30:00 5.7 0.6 6.8 3.8 5.7 0.7 6.8 4.2 37 5 33 305 0.3 0 0.6 0.3 05/30/2005 01:40:00 5.8 0.3 6.8 5.3 6 0.4 6.8 4.9 40 4 37 305 0.4 0 0.6 0.3 05/30/2005 01:50:00 5.8 0.4 6.8 4.9 6 0.4 7.2 4.9 38 3 39 305 0.4 0 0.6 0.3 05/30/2005 02:00:00 4.5 0.4 5.7 3.4 4.5 0.4 5.7 3.4 31 3 35 305 0.4 0 0.6 0.3 05/30/2005 02:10:00 4.5 0.4 5.3 3.4 4.6 0.4 5.3 3.4 32 2 27 305 0.4 0 0.8 0.3 05/30/2005 02:20:00 5 0.3 5.7 4.2 5.1 0.3 5.7 4.2 34 3 36 305 0.4 0 1 0.3 05/30/2005 02:30:00 4.5 0.3 5.3 3.4 4.6 0.3 5.3 3.8 33 3 33 305 0.4 0 1 0.3 05/30/2005 02:40:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 4.2 31 4 32 305 0.5 0 1 0.3 05/30/2005 02:50:00 5.5 0.5 6.5 4.6 5.6 0.5 6.8 4.2 31 3 36 305 0.5 0 0.8 0.3 05/30/2005 03:00:00 6.4 0.4 7.2 5.7 6.5 0.4 7.6 5.3 35 3 33 305 0.5 0 0.8 0.3 05/30/2005 03:10:00 6 0.7 7.2 4.6 6.1 0.7 7.2 4.6 33 3 37 305 0.5 0 1 0.3 05/30/2005 03:20:00 4.4 0.4 5.3 3.8 4.6 0.4 5.7 3.8 24 5 30 305 0.5 0 1 0.3 05/30/2005 03:30:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 27 6 29 305 0.4 0 0.8 0.3 05/30/2005 03:40:00 4 0.3 4.9 3 4 0.3 4.9 3 27 4 23 305 0.4 0 0.8 0.3 05/30/2005 03:50:00 5.7 0.5 7.2 4.6 5.7 0.5 7.2 4.6 29 4 24 305 0.4 0 1 0.3 05/30/2005 04:00:00 6.2 0.5 7.6 4.9 6.1 0.6 7.2 4.6 21 6 16 305 0.4 0 1 0.3 05/30/2005 04:10:00 7.7 0.4 8.8 6.8 7.7 0.5 8.8 6.1 20 4 21 305 0.4 0 1 0.3 05/30/2005 04:20:00 6.6 0.4 8 5.7 6.5 0.4 8 5.7 28 2 29 305 0.4 0 0.6 0.3 05/30/2005 04:30:00 5.8 0.5 6.8 4.6 5.8 0.5 6.8 4.6 30 3 28 305 0.4 0 1 0.3 05/30/2005 04:40:00 5 0.3 5.7 4.2 5 0.3 5.7 4.6 26 4 34 305 0.5 0 0.6 0.3 05/30/2005 04:50:00 5.6 0.2 6.1 4.9 5.6 0.3 6.1 4.6 28 3 29 305 0.5 0 1 0.3 05/30/2005 05:00:00 5.9 0.3 6.8 4.9 5.8 0.3 6.5 4.9 28 2 29 305 0.5 0 1 0.3 05/30/2005 05:10:00 5.2 0.3 6.1 4.2 5.1 0.3 5.7 4.6 28 3 28 305 0.4 0 1 0.3 05/30/2005 05:20:00 5.1 0.4 6.1 4.2 5.1 0.4 6.1 4.2 27 4 28 305 0.4 0 1 0.3 05/30/2005 05:30:00 6.2 0.4 7.2 5.3 6.2 0.4 7.2 4.9 34 4 42 305 0.4 0 0.8 0.3 05/30/2005 05:40:00 6.3 0.4 7.6 5.3 6.4 0.4 7.2 5.3 35 5 36 305 0.3 0 0.8 0.3 05/30/2005 05:50:00 6.4 0.4 7.2 5.3 6.4 0.4 7.2 5.3 34 5 40 305 0.3 0 0.8 0.3 05/30/2005 06:00:00 5.7 0.3 6.5 4.9 5.6 0.4 6.5 4.6 33 4 30 305 0.3 0 0.6 0.3 05/30/2005 06:10:00 6.5 0.5 7.6 5.3 6.5 0.5 7.6 5.7 37 5 39 305 0.3 0 0.6 0.3 05/30/2005 06:20:00 6.9 0.5 8.4 5.7 6.8 0.5 8 5.3 40 6 47 305 0.4 0 0.6 0.3 05/30/2005 06:30:00 6.5 0.5 7.6 5.3 6.5 0.5 8 4.9 35 5 36 305 0.4 0 0.6 0.3 05/30/2005 06:40:00 6.1 0.3 6.8 5.3 6.1 0.3 6.8 5.3 35 4 36 305 0.4 0 0.6 0.3 05/30/2005 06:50:00 6.1 0.4 7.2 4.9 6.1 0.5 6.8 4.6 38 4 32 305 0.4 0 0.6 0.3 05/30/2005 07:00:00 6.4 0.5 7.6 4.9 6.4 0.5 7.6 4.9 39 5 43 305 0.3 0 0.6 0.3 05/30/2005 07:10:00 7.1 0.5 8.8 5.7 7.1 0.5 8.8 5.7 42 5 37 305 0.4 0 0.8 0.3 05/30/2005 07:20:00 6.9 0.5 8 5.7 6.9 0.6 8.4 5.7 36 4 37 305 0.4 0 0.8 0.3 05/30/2005 07:30:00 6.2 0.5 7.6 4.9 6.3 0.5 7.6 4.9 36 5 36 305 0.5 0 0.8 0.3 05/30/2005 07:40:00 6.5 0.6 8.4 5.3 6.6 0.6 8.4 4.9 40 6 31 305 0.5 0 1 0.6 05/30/2005 07:50:00 6.8 0.4 8 5.3 6.9 0.5 8.4 5.3 37 5 40 305 0.6 0.1 1 0.6 05/30/2005 08:00:00 6.8 0.4 8 5.7 6.7 0.4 7.6 5.3 37 5 32 305 0.7 0 1.3 0.6 05/30/2005 08:10:00 7.5 0.8 9.1 5.7 7.5 0.9 9.5 5.3 40 6 40 305 1 0.1 1.5 0.8 05/30/2005 08:20:00 8.2 0.7 10.3 6.5 8 0.7 9.9 6.1 45 6 44 305 1.3 0 1.5 1 05/30/2005 08:30:00 8.7 0.8 11.1 6.5 8.6 0.8 10.7 6.5 42 6 41 305 1.8 0.1 2.5 1.5 05/30/2005 08:40:00 8.9 0.8 11.8 6.8 8.8 0.9 11.5 6.5 44 7 40 305 2 0 2.7 2 05/30/2005 08:50:00 8.9 0.7 11.1 7.2 8.8 0.7 10.3 6.8 42 6 47 305 2.2 0.1 2.7 2 05/30/2005 09:00:00 8.5 0.6 10.3 7.2 8.5 0.7 10.3 6.1 40 6 32 305 2.2 0.1 2.7 2 05/30/2005 09:10:00 7.5 0.5 8.8 6.5 7.5 0.6 8.8 6.1 41 6 47 305 2 0.1 2.5 1.7 05/30/2005 09:20:00 7.2 0.6 8.8 5.7 7.2 0.6 8.8 5.7 41 6 33 305 1.9 0.1 2.2 1.7 05/30/2005 09:30:00 6.6 0.5 8 5.3 6.5 0.6 8.8 4.9 41 6 39 305 2 0 2.5 2 05/30/2005 09:40:00 6.7 0.6 8.4 5.3 6.6 0.7 8 4.9 40 6 36 305 2.1 0.1 2.5 2 05/30/2005 09:50:00 7.4 0.6 9.1 5.7 7.3 0.6 9.1 5.7 41 5 38 305 2.1 0 2.5 2 05/30/2005 10:00:00 7.4 0.6 9.1 6.1 7.3 0.6 9.1 5.3 42 6 46 305 2.2 0.2 2.9 2 05/30/2005 10:10:00 7.6 0.7 9.1 5.7 7.5 0.8 9.9 4.9 41 6 32 305 2.5 0 2.9 2.2 05/30/2005 10:20:00 7.9 0.7 9.9 6.1 7.8 0.8 10.3 5.3 45 6 40 305 2.3 0.1 2.9 2.2 05/30/2005 10:30:00 7.9 0.7 10.7 6.1 7.8 0.7 9.5 5.7 43 7 39 305 2.3 0.1 2.9 2.2 05/30/2005 10:40:00 8.5 0.7 10.3 6.5 8.5 0.8 10.7 6.1 40 7 31 305 2.3 0.2 2.7 2 05/30/2005 10:50:00 8.1 0.7 9.9 5.7 8.1 0.8 9.9 6.1 43 6 40 305 2.3 0.1 2.7 2 05/30/2005 11:00:00 8.2 0.8 10.3 6.1 8.2 0.9 10.3 5.7 51 7 50 305 2.6 0.2 3.2 2.2 05/30/2005 11:10:00 9.2 0.6 11.5 7.6 9.2 0.6 11.1 7.6 49 6 48 305 3 0.2 3.7 2.7 05/30/2005 11:20:00 8.9 0.7 10.7 6.1 8.9 0.7 10.7 6.8 49 6 53 305 2.9 0.2 3.4 2.7 05/30/2005 11:30:00 8.4 0.8 11.1 6.5 8.4 0.9 11.1 6.5 50 7 53 305 2.8 0.2 3.4 2.7 05/30/2005 11:40:00 7.2 0.8 9.5 5.3 7.2 0.9 9.5 5.3 48 7 51 305 3 0.2 3.7 2.7 05/30/2005 11:50:00 7.5 0.6 9.1 5.3 7.5 0.7 9.1 5.7 41 6 36 305 2.8 0.1 3.4 2.5 05/30/2005 12:00:00 7 0.7 8.4 5.7 7 0.7 8.8 5.3 42 6 41 305 3.2 0.1 3.7 2.7 05/30/2005 12:10:00 6.3 0.5 7.6 4.9 6.3 0.5 7.6 4.9 45 6 48 305 3.1 0.1 3.7 2.9 05/30/2005 12:20:00 6 0.4 7.2 4.9 5.9 0.4 7.2 4.9 34 5 36 305 3.3 0.2 3.7 2.9 05/30/2005 12:30:00 5.6 0.4 6.5 4.6 5.4 0.4 6.5 4.6 30 3 34 305 3.3 0.1 3.7 2.9 05/30/2005 12:40:00 5 0.4 6.1 3.8 5 0.4 6.5 3.8 29 4 24 305 2.8 0.2 3.4 2.5 05/30/2005 12:50:00 4.3 0.3 5.3 3.4 4.3 0.3 5.7 3.4 26 3 25 305 2.7 0.1 3.2 2.5 05/30/2005 13:00:00 4.3 0.3 4.9 3.8 4.3 0.3 5.3 3.4 29 4 32 305 2.8 0.1 3.2 2.5 05/30/2005 13:10:00 4.9 0.4 5.7 3.4 4.9 0.4 5.7 3.8 34 5 33 305 2.9 0.2 3.4 2.5 05/30/2005 13:20:00 5.3 0.5 6.5 3.8 5.3 0.5 6.5 4.2 36 5 34 305 2.9 0.2 3.7 2.5 05/30/2005 13:30:00 5.8 0.4 6.8 4.9 5.9 0.5 7.2 4.6 39 5 46 305 3.1 0.1 3.7 2.9 05/30/2005 13:40:00 5.6 0.5 6.8 4.2 5.7 0.5 6.8 4.6 36 6 36 305 3.1 0.1 3.7 2.9 05/30/2005 13:50:00 6.1 0.6 8 4.9 6.1 0.6 8 4.6 36 5 32 305 3.3 0.1 3.7 3.2 05/30/2005 14:00:00 6.3 0.5 7.6 4.9 6.3 0.5 7.6 4.9 38 6 41 305 3.4 0.2 4.2 3.2 05/30/2005 14:10:00 6.6 0.5 8.4 5.3 6.6 0.6 8.4 4.9 41 5 45 305 3.6 0.1 4.2 3.2 05/30/2005 14:20:00 5.9 0.4 6.8 4.6 6 0.5 7.2 4.6 41 6 38 305 3.4 0.2 4.2 3.2 05/30/2005 14:30:00 5.4 0.5 6.8 4.2 5.4 0.5 6.5 4.2 37 8 29 305 3.3 0.1 3.7 2.9 05/30/2005 14:40:00 6.2 0.4 7.2 4.9 6.3 0.4 7.2 4.9 36 5 39 305 3.4 0.2 3.9 2.9 05/30/2005 14:50:00 6.8 0.5 8.4 5.3 6.8 0.5 8.4 5.3 38 6 33 305 3.6 0.2 4.2 3.2 05/30/2005 15:00:00 6.8 0.4 8 5.7 6.8 0.5 7.6 5.3 40 5 39 305 3.7 0 4.2 3.4 05/30/2005 15:10:00 6.9 0.5 8 5.7 6.9 0.5 8 5.3 42 6 34 305 3.7 0.2 4.2 3.2 05/30/2005 15:20:00 7 0.5 8.4 5.7 7.1 0.5 8.4 5.7 41 5 40 305 3.1 0.2 3.7 2.7 05/30/2005 15:30:00 6.9 0.5 8.4 5.3 6.9 0.6 8.8 5.3 42 5 43 305 3.1 0.1 3.7 2.9 05/30/2005 15:40:00 7.4 0.5 9.1 6.1 7.4 0.5 8.8 6.5 41 6 54 305 3 0.1 3.4 2.7 05/30/2005 15:50:00 7.4 0.6 8.8 5.7 7.4 0.7 9.1 5.7 42 6 40 305 2.8 0.1 3.4 2.5 05/30/2005 16:00:00 7.5 0.7 8.8 5.7 7.5 0.7 9.1 6.1 41 6 41 305 2.6 0.1 3.2 2.2 05/30/2005 16:10:00 7.8 0.6 9.5 6.5 7.9 0.6 9.5 6.5 44 7 54 305 2.4 0.1 2.9 2.2 05/30/2005 16:20:00 8.2 0.5 9.9 6.8 8.2 0.6 9.9 6.5 46 6 52 305 2.3 0.1 2.9 2 05/30/2005 16:30:00 8.1 0.5 9.1 6.8 8.1 0.6 9.5 6.1 44 6 43 305 2.1 0.1 2.7 1.7 05/30/2005 16:40:00 8.3 0.5 9.9 6.8 8.4 0.6 9.5 6.8 43 5 47 305 2 0.1 2.5 2 05/30/2005 16:50:00 8.4 0.6 10.3 6.8 8.5 0.7 10.7 6.8 43 6 50 305 2 0.2 2.5 1.7 05/30/2005 17:00:00 8.2 0.6 10.7 6.8 8.2 0.6 10.7 6.5 46 6 39 305 2 0.2 2.5 1.7 05/30/2005 17:10:00 8.2 0.5 9.9 6.8 8.3 0.5 9.5 6.8 49 6 39 305 2 0.2 2.5 1.7 05/30/2005 17:20:00 7.9 0.5 9.9 6.5 8.2 0.5 9.9 6.5 49 6 54 305 1.9 0.2 2.5 1.5 05/30/2005 17:30:00 7.5 0.6 9.5 5.7 7.7 0.6 9.5 6.1 49 5 48 305 1.8 0.2 2.2 1.5 05/30/2005 17:40:00 7.2 0.5 8.8 5.7 7.3 0.5 8.8 6.1 48 5 61 305 1.7 0.1 2.2 1.5 05/30/2005 17:50:00 7.3 0.5 8.8 5.7 7.3 0.5 8.8 6.1 48 5 52 305 1.7 0.1 2.2 1.5 05/30/2005 18:00:00 7.2 0.5 9.1 6.1 7.3 0.5 9.1 5.7 47 5 40 305 1.6 0.1 2.2 1.5 05/30/2005 18:10:00 7.6 0.4 9.1 6.5 7.8 0.5 9.1 6.1 49 5 40 305 1.6 0 2.2 1.3 05/30/2005 18:20:00 7.6 0.6 9.9 5.7 7.7 0.6 9.5 6.1 50 6 37 305 1.4 0 2 1.3 05/30/2005 18:30:00 7.8 0.5 9.1 6.5 8 0.6 9.5 6.8 52 5 48 305 1.4 0 2 1.3 05/30/2005 18:40:00 8 0.5 9.5 6.8 8.1 0.6 9.9 6.5 50 5 53 305 1.3 0 1.5 1.3 05/30/2005 18:50:00 8.2 0.5 9.5 7.2 8.3 0.5 9.9 6.8 51 5 47 305 1.3 0.1 1.5 1 05/30/2005 19:00:00 8.1 0.5 9.9 6.8 8.1 0.5 9.5 6.8 51 5 37 305 1.2 0.1 1.5 1 05/30/2005 19:10:00 8.2 0.4 9.5 7.2 8.2 0.4 9.5 7.2 52 4 51 305 1.1 0 1.5 1 05/30/2005 19:20:00 8.7 0.4 9.9 7.6 8.8 0.4 10.3 7.6 55 3 60 305 1 0 1.5 1 05/30/2005 19:30:00 9 0.4 9.9 8 9.1 0.4 9.9 8 56 3 54 305 1.1 0.1 1.5 1 05/30/2005 19:40:00 9.3 0.3 10.3 8.4 9.4 0.4 10.3 8 58 2 57 305 1 0 1.5 1 05/30/2005 19:50:00 9.2 0.4 10.3 8.4 9.3 0.4 10.3 7.6 59 3 60 305 1.2 0 1.5 1 05/30/2005 20:00:00 9.1 0.4 9.9 8 9.2 0.4 10.3 8 51 3 52 305 1 0 1.5 1 05/30/2005 20:10:00 9 0.4 10.3 7.6 9 0.5 10.3 7.2 52 3 45 305 1 0 1.5 0.8 05/30/2005 20:20:00 9 0.4 10.7 8 9 0.5 10.3 7.2 49 4 51 305 1 0 1.5 0.8 05/30/2005 20:30:00 9.3 0.4 10.3 8 9.3 0.4 10.7 8 52 3 48 305 1 0 1.5 0.8 05/30/2005 20:40:00 9.5 0.3 10.3 8.8 9.5 0.4 10.7 8.4 52 3 56 305 1 0 1.5 0.8 05/30/2005 20:50:00 9.8 0.3 10.7 9.1 9.8 0.4 10.7 8.4 52 3 56 305 1 0 1.5 1 05/30/2005 21:00:00 10.1 0.4 11.1 9.1 10.1 0.5 11.5 8.8 55 2 59 305 1 0 1.3 1 05/30/2005 21:10:00 10.6 0.8 12.6 8.4 10.4 0.8 12.2 8 59 5 70 305 1.2 0.1 1.5 1 05/30/2005 21:20:00 10.8 0.7 12.6 9.1 10.6 0.8 12.6 8.8 58 5 57 305 1.2 0.1 1.7 1 05/30/2005 21:30:00 11.1 0.8 13.3 9.1 11 0.8 13 8.4 58 5 64 305 1.1 0 1.5 1 05/30/2005 21:40:00 10.6 0.8 12.6 8 10.4 0.9 12.6 7.6 59 6 63 305 1 0 1.5 1 05/30/2005 21:50:00 11 0.6 12.2 8.8 10.9 0.7 12.6 8.8 57 5 60 305 0.9 0.1 1.5 0.6 05/30/2005 22:00:00 11 0.8 13.7 8.8 11 0.9 13.7 8 60 7 74 305 0.7 0.1 1.3 0.6 05/30/2005 22:10:00 10.7 1 13.7 8.4 10.4 1 13.3 7.2 65 8 76 305 0.7 0.1 1.3 0.6 05/30/2005 22:20:00 10.5 0.9 12.6 8 10.2 0.9 12.6 8 68 8 82 305 0.7 0.1 1.3 0.6 05/30/2005 22:30:00 10.5 0.9 12.6 8.4 10 0.9 13 7.6 75 8 77 305 0.9 0 1.5 0.8 05/30/2005 22:40:00 10.4 1 13 7.6 9.9 1 13 7.2 75 7 79 305 0.9 0 1.3 0.6 05/30/2005 22:50:00 11 0.8 13 8.4 10 0.9 12.2 6.5 85 6 90 305 0.7 0.1 1.3 0.6 05/30/2005 23:00:00 11.8 0.7 13.3 9.9 10.8 0.8 13 8.8 89 4 93 305 0.6 0.1 1.3 0.6 05/30/2005 23:10:00 12.2 0.6 14.1 10.7 11.3 0.7 13 9.5 94 4 96 305 0.6 0.1 1.3 0.6 05/30/2005 23:20:00 12 0.6 13.3 9.1 11.1 0.7 12.6 8.4 95 3 99 305 0.7 0.1 1.3 0.6 05/30/2005 23:30:00 9.6 1.2 13 6.5 8.6 1.2 11.5 5.7 94 5 93 305 0.6 0.1 1.3 0.6 05/30/2005 23:40:00 5.4 2.7 9.9 0.4 4.8 2.3 9.5 0.4 101 32 96 305 0.7 0.2 1.3 0.6 05/30/2005 23:50:00 3.3 1.3 5.7 0.4 3.7 1.2 5.7 0.4 356 32 357 305 0.8 0.1 1.5 0.6 05/31/2005 00:00:00 5.6 1.1 8 3.4 5.7 1 9.1 3.8 36 13 39 305 0.6 0.1 1.3 0.6 05/31/2005 00:10:00 8.3 0.6 9.5 6.5 8.4 0.6 9.5 6.1 53 4 53 305 0.7 0.2 1.3 0.6 05/31/2005 00:20:00 6.3 0.8 8.8 4.6 6.3 0.8 8.8 4.9 47 6 52 305 0.7 0.2 1.3 0.6 05/31/2005 00:30:00 5.6 0.6 7.2 3.8 5.4 0.5 6.8 4.2 35 6 42 305 0.7 0.2 1.3 0.6 05/31/2005 00:40:00 5 0.7 7.2 2.6 5.1 0.7 6.5 3 31 8 36 305 1 0.1 1.5 0.8 05/31/2005 00:50:00 4.2 1 6.5 1.1 4.6 0.8 6.5 2.3 8 13 29 305 1.1 0.1 1.5 1 05/31/2005 01:00:00 4.1 1.2 6.5 0.4 4.6 1.1 7.2 0.7 9 20 16 305 1.3 0.1 2 1.3 05/31/2005 01:10:00 6.2 1.6 9.1 2.6 6.6 1.5 9.9 3.4 34 14 47 305 1.6 0.2 2.2 1.3 05/31/2005 01:20:00 7.5 1.1 10.3 4.9 8.1 1.1 11.1 5.7 53 12 44 305 1.5 0.4 2.7 1 05/31/2005 01:30:00 8.1 1.1 10.7 4.6 9.1 1 11.5 5.3 54 9 51 305 1.4 0.4 2.7 1 05/31/2005 01:40:00 6.2 1.9 9.9 1.9 7.1 1.6 10.3 3 40 12 41 305 1.1 0.2 1.5 1 05/31/2005 01:50:00 6.8 1.8 10.7 3.4 7.6 1.8 11.5 3.8 48 9 43 305 1.6 0.3 2.7 1 05/31/2005 02:00:00 7.7 1 9.9 4.6 8.3 1.2 11.1 5.3 56 9 56 305 1.7 0.3 2.7 1 05/31/2005 02:10:00 5.7 1.5 9.9 1.9 6.2 1.6 9.9 2.6 58 14 54 305 2 0.4 2.9 1.3 05/31/2005 02:20:00 2.5 1.7 7.6 0.4 2.6 1.5 8 0.4 95 76 99 305 2.1 0.3 2.9 1.5 05/31/2005 02:30:00 1.5 0.8 4.2 0.4 1.9 1 4.6 0.4 115 69 77 305 2.3 0.2 2.9 1.7 05/31/2005 02:40:00 1.3 1.1 4.2 0.4 1.6 1.2 4.6 0.4 100 53 37 305 2.2 0 2.7 2 05/31/2005 02:50:00 1.6 1.1 4.6 0.4 2 1.1 4.6 0.4 50 39 20 305 2.1 0.2 2.9 1.7 05/31/2005 03:00:00 3.2 1.1 6.1 1.5 3.8 1 6.5 1.9 37 13 32 305 1.6 0.2 2.2 1 05/31/2005 03:10:00 5 1.7 8.8 0.7 5.5 1.7 9.1 1.5 39 15 39 305 1.2 0.3 2 0.6 05/31/2005 03:20:00 7.6 1.1 9.9 4.9 8 1 10.3 4.2 46 8 46 305 0.4 0 1 0.3 05/31/2005 03:30:00 7.6 1 9.9 4.9 8.1 1 9.9 4.6 44 7 45 305 0.4 0 1 0.3 05/31/2005 03:40:00 8.1 1 10.3 5.7 8.6 0.9 10.3 5.7 45 6 45 305 0.3 0.1 1 0.1 05/31/2005 03:50:00 5.3 1 7.6 3 5.4 1 8.4 3.4 57 19 45 305 0.5 0 1 0.3 05/31/2005 04:00:00 5.3 1.3 8.4 2.3 5.1 1.2 7.6 2.3 62 11 64 305 0.8 0.3 2 0.3 05/31/2005 04:10:00 7.1 0.8 8.8 4.2 6.6 0.8 8.8 4.6 68 5 66 305 1.6 0.2 2.2 1 05/31/2005 04:20:00 7.5 0.7 9.1 5.7 6.9 0.8 9.1 4.9 68 5 73 305 1.8 0.1 2.5 1.5 05/31/2005 04:30:00 6.5 0.8 8.4 4.6 6 0.8 8 3.8 66 8 63 305 2 0.1 2.5 1.5 05/31/2005 04:40:00 5.1 0.9 7.6 3.4 4.5 0.8 7.2 3 66 8 65 305 1.6 0.2 2.2 1 05/31/2005 04:50:00 4.1 1 6.5 1.9 3.9 1 6.1 1.9 64 10 74 305 1.4 0.2 2.2 0.8 05/31/2005 05:00:00 5 0.7 6.8 1.9 4.7 0.7 6.1 2.3 66 7 65 305 1.6 0.1 2.2 1.3 05/31/2005 05:10:00 4.8 1 6.8 2.6 4.7 1.3 7.6 1.9 61 14 53 305 1.3 0.4 2.2 0.6 05/31/2005 05:20:00 6.4 0.5 7.6 4.9 6.8 0.4 7.6 4.9 44 5 52 305 0.4 0 1 0.3 05/31/2005 05:30:00 6.9 0.3 7.6 6.1 7 0.3 7.6 6.1 39 2 38 305 0.3 0 0.8 0.1 05/31/2005 05:40:00 6.8 0.4 8 5.7 6.9 0.4 8 5.7 39 3 41 305 0.3 0.1 0.8 0.1 05/31/2005 05:50:00 5.7 0.5 6.8 4.2 5.7 0.6 6.8 4.2 37 3 38 305 0.2 0.1 0.8 0.1 05/31/2005 06:00:00 5.6 0.4 6.8 4.6 5.6 0.4 6.5 4.2 37 4 37 305 0.2 0.1 0.8 0.1 05/31/2005 06:10:00 6.1 0.4 6.8 4.9 6.1 0.4 6.8 4.9 36 3 36 305 0.2 0.1 0.6 0.1 05/31/2005 06:20:00 6.7 0.3 7.2 5.7 6.7 0.3 7.2 5.7 38 3 36 305 0.2 0.1 0.6 0.1 05/31/2005 06:30:00 6.3 0.3 6.8 5.3 6.4 0.3 7.2 5.7 41 2 42 305 0.2 0.1 0.6 0.1 05/31/2005 06:40:00 6.2 0.3 6.8 5.3 6.3 0.4 7.2 5.3 42 3 37 305 0.2 0 0.6 0.1 05/31/2005 06:50:00 5.8 0.4 6.8 4.9 6 0.4 6.8 4.6 44 3 48 305 0.2 0.1 0.6 0.1 05/31/2005 07:00:00 5.8 0.3 6.5 4.9 6 0.3 6.8 4.9 39 3 43 305 0.2 0.1 0.6 0.1 05/31/2005 07:10:00 5.8 0.2 6.5 4.9 6.1 0.3 6.8 4.9 38 3 35 305 0.2 0 0.6 0.1 05/31/2005 07:20:00 5.7 0.3 6.5 4.6 6.1 0.4 6.8 4.9 41 3 34 305 0.2 0 0.6 0.1 05/31/2005 07:30:00 5.6 0.5 6.5 4.2 6.1 0.5 7.2 4.6 40 4 37 305 0.2 0 0.6 0.1 05/31/2005 07:40:00 5.6 0.3 6.5 4.6 6.2 0.4 7.2 4.9 48 3 47 305 0.1 0.1 0.6 0.1 05/31/2005 07:50:00 5.9 0.4 6.5 4.6 6.6 0.5 7.2 4.9 45 4 42 305 0.1 0.1 0.6 0.1 05/31/2005 08:00:00 5.9 0.4 6.8 4.9 6.6 0.5 7.6 5.3 46 3 44 305 0.1 0.1 0.6 0.1 05/31/2005 08:10:00 6 0.3 6.5 4.9 6.8 0.4 7.6 5.7 42 2 41 305 0.1 0.1 0.6 0.1 05/31/2005 08:20:00 5.4 0.3 6.5 4.6 6.3 0.4 7.2 4.9 40 2 39 305 0.1 0.1 0.6 0.1 05/31/2005 08:30:00 5.3 0.3 6.1 4.6 6.2 0.4 6.8 4.6 41 3 37 305 0.1 0.1 0.6 0.1 05/31/2005 08:40:00 6.3 0.4 7.2 5.3 7.1 0.5 8 6.1 45 2 45 305 0.1 0.1 0.6 0.1 05/31/2005 08:50:00 6.4 0.4 7.2 5.3 7.3 0.5 8.4 6.1 46 2 47 305 0 0.1 0.6 0.1 05/31/2005 09:00:00 5.7 0.4 6.5 4.6 6.4 0.5 7.6 4.9 43 3 41 305 0.1 0.1 0.6 0.1 05/31/2005 09:10:00 5.9 0.5 6.8 4.2 6.4 0.7 7.6 4.6 46 3 46 305 0.3 0 0.6 0.1 05/31/2005 09:20:00 5.3 0.6 6.5 3.8 5.8 0.7 7.6 3.8 49 5 50 305 0.4 0 0.8 0.3 05/31/2005 09:30:00 5.2 0.5 6.1 3.4 5.8 0.7 7.2 4.2 48 5 47 305 0.4 0 0.8 0.3 05/31/2005 09:40:00 5.4 0.4 6.5 3.8 6.3 0.6 7.2 4.6 47 3 47 305 0.3 0 0.6 0.1 05/31/2005 09:50:00 5.3 0.5 6.5 3.8 6.3 0.6 7.6 4.6 51 4 57 305 0.3 0 0.6 0.1 05/31/2005 10:00:00 5.4 0.5 6.5 3.8 6.1 0.6 7.2 4.6 51 4 52 305 0.3 0 0.6 0.1 05/31/2005 10:10:00 4.4 0.7 6.1 2.3 5.2 0.9 7.2 3 50 6 51 305 0.3 0 0.6 0.1 05/31/2005 10:20:00 4.3 0.4 5.3 3 5.2 0.5 6.5 3.4 47 4 43 305 0.1 0.1 0.6 0.1 05/31/2005 10:30:00 4.4 0.5 5.7 3 5.3 0.6 6.5 3.4 45 6 40 305 0.2 0.1 0.6 0.1 05/31/2005 10:40:00 4.7 0.3 5.3 3.4 5.5 0.5 6.1 3.4 42 4 39 305 0.2 0.1 0.6 0.1 05/31/2005 10:50:00 4.7 0.3 5.3 3.8 5.7 0.5 6.5 4.2 38 3 42 305 0.1 0.1 0.6 0.1 05/31/2005 11:00:00 4.8 0.4 5.7 3.4 5.8 0.6 6.8 4.2 41 4 38 305 0.2 0 0.6 0.1 05/31/2005 11:10:00 4.8 0.4 5.7 3.8 5.8 0.4 6.8 4.6 41 3 41 305 0.2 0.1 0.8 0.1 05/31/2005 11:20:00 4.7 0.4 5.3 3.8 5.8 0.4 6.5 4.9 39 3 39 305 0.3 0 0.8 0.1 05/31/2005 11:30:00 5.5 0.4 6.5 4.2 7 0.7 8.4 5.3 41 3 45 305 0.4 0 0.8 0.1 05/31/2005 11:40:00 5.6 0.3 6.5 4.6 7.4 0.5 8.4 6.1 42 3 45 305 0.4 0.1 1 0.1 05/31/2005 11:50:00 5.8 0.3 6.5 4.9 7.6 0.5 8.8 6.1 44 3 45 305 0.4 0 1 0.3 05/31/2005 12:00:00 5 0.4 5.7 3.4 6.6 0.5 7.6 4.9 42 3 41 305 0.4 0.1 1 0.3 05/31/2005 12:10:00 5 0.3 5.7 3.8 6.6 0.4 7.6 5.3 37 3 39 305 0.4 0.1 1 0.1 05/31/2005 12:20:00 5.6 0.4 6.5 4.6 7.5 0.6 8.8 5.3 39 3 38 305 0.4 0.1 1 0.1 05/31/2005 12:30:00 5.4 0.4 6.5 4.6 7.3 0.5 8.8 6.1 38 3 39 305 0.4 0 1 0.3 05/31/2005 12:40:00 5.4 0.5 6.5 4.2 7.2 0.8 8.4 4.9 41 3 45 305 0.4 0.1 1.3 0.3 05/31/2005 12:50:00 5.3 0.4 6.1 4.2 7.4 0.6 8.8 4.9 38 2 38 305 0.4 0 1 0.3 05/31/2005 13:00:00 5.2 0.3 5.7 3.8 8.1 0.5 9.1 6.1 42 2 41 305 0.5 0 1.3 0.3 05/31/2005 13:10:00 5 0.3 5.7 4.2 7.7 0.5 8.8 6.5 45 3 44 305 0.5 0 1 0.3 05/31/2005 13:20:00 4.7 0.2 5.3 4.2 7.3 0.4 8 5.7 39 3 38 305 0.4 0 1 0.3 05/31/2005 13:30:00 7.4 0.9 8.8 4.2 7.6 0.6 9.1 6.1 43 3 41 305 0.6 0.1 1.3 0.6 05/31/2005 13:40:00 6.8 0.4 7.6 5.3 6.8 0.4 8 5.3 40 4 43 305 0.7 0.1 1.3 0.6 05/31/2005 13:50:00 6.3 0.4 7.2 4.9 6.4 0.5 7.2 4.9 36 3 40 305 0.6 0 1 0.3 05/31/2005 14:00:00 6.9 0.5 8 5.7 6.9 0.5 8 5.3 42 5 49 305 0.6 0.1 1 0.3 05/31/2005 14:10:00 8 0.5 8.8 6.1 8 0.5 9.1 6.1 46 3 46 305 0.7 0.2 1.5 0.6 05/31/2005 14:20:00 7.8 0.3 8.4 7.2 7.8 0.4 8.8 6.5 45 2 48 305 0.7 0.1 1.3 0.6 05/31/2005 14:30:00 7.2 0.4 8 6.1 7.2 0.4 8.4 5.7 42 3 43 305 0.6 0.1 1.3 0.6 05/31/2005 14:40:00 6.8 0.4 7.6 5.7 6.9 0.4 8 5.7 43 3 40 305 0.7 0.1 1.3 0.6 05/31/2005 14:50:00 6.3 0.4 7.2 4.9 6.4 0.4 7.2 4.9 44 3 37 305 0.6 0.1 1.3 0.6 05/31/2005 15:00:00 5.8 0.4 6.8 4.6 5.9 0.5 6.8 4.2 45 5 45 305 0.6 0.1 1 0.3 05/31/2005 15:10:00 5.8 0.3 6.8 4.9 5.9 0.3 6.8 4.9 45 4 51 305 0.6 0.1 1.3 0.6 05/31/2005 15:20:00 5.6 0.5 6.8 4.6 5.5 0.5 6.5 4.2 41 4 49 305 0.6 0.1 1 0.3 05/31/2005 15:30:00 5.9 0.4 6.8 4.9 5.9 0.5 6.8 4.2 40 3 38 305 0.7 0.1 1.3 0.6 05/31/2005 15:40:00 5.6 0.4 6.8 4.6 5.5 0.4 6.5 4.2 41 3 41 305 0.7 0.2 1.3 0.6 05/31/2005 15:50:00 5.7 0.5 6.8 4.2 5.8 0.5 6.8 4.6 41 3 46 305 0.7 0.1 1.5 0.6 05/31/2005 16:00:00 6.5 0.4 7.2 5.3 6.5 0.5 7.6 4.9 42 4 43 305 0.9 0.2 1.5 0.6 05/31/2005 16:10:00 6.7 0.5 7.6 5.3 6.8 0.5 7.6 4.9 43 3 46 305 0.8 0.1 1.5 0.6 05/31/2005 16:20:00 5.8 0.5 6.8 4.2 5.8 0.5 6.8 4.6 44 4 44 305 1 0.1 1.5 0.6 05/31/2005 16:30:00 5.9 0.6 7.2 4.2 5.8 0.6 7.2 4.2 35 6 44 305 1.1 0.2 1.7 0.8 05/31/2005 16:40:00 5.9 0.4 6.8 4.9 5.9 0.4 6.8 4.9 38 4 46 305 0.9 0.1 1.5 0.8 05/31/2005 16:50:00 5.6 0.5 6.8 4.2 5.6 0.6 6.8 3.8 43 5 39 305 1.1 0.1 1.5 0.8 05/31/2005 17:00:00 5.2 0.4 6.5 4.2 5.2 0.4 6.1 4.2 42 5 47 305 1.2 0.1 1.7 1 05/31/2005 17:10:00 5.5 0.4 6.8 4.2 5.4 0.5 6.8 4.2 43 5 43 305 1.3 0.1 1.7 1 05/31/2005 17:20:00 6.2 0.7 7.6 4.9 6 0.8 7.6 4.2 39 5 35 305 1.4 0.1 2 1 05/31/2005 17:30:00 6.8 0.4 7.6 5.3 6.8 0.5 8 5.3 37 3 34 305 1.2 0.1 1.5 1 05/31/2005 17:40:00 7 0.5 8.4 5.3 7 0.5 8.4 5.3 37 3 35 305 1.2 0.1 1.5 1 05/31/2005 17:50:00 7.8 0.4 8.4 6.5 7.7 0.5 8.8 6.1 38 3 37 305 1 0.1 1.5 0.6 05/31/2005 18:00:00 7.7 0.5 9.1 6.5 7.5 0.7 9.1 5.3 38 3 36 305 0.9 0.1 1.5 0.6 05/31/2005 18:10:00 8 0.4 9.1 6.5 7.7 0.5 8.8 6.1 33 3 34 305 1 0.1 1.5 0.6 05/31/2005 18:20:00 8.2 0.4 9.1 6.8 8.1 0.6 9.1 6.1 33 3 32 305 1.3 0.2 2 1 05/31/2005 18:30:00 8.6 0.4 9.1 7.6 8.5 0.5 9.5 6.5 28 2 24 305 1.2 0.2 1.7 0.8 05/31/2005 18:40:00 9.3 0.4 10.3 8 9.2 0.5 10.3 7.6 36 3 33 305 1.2 0.3 1.7 0.6 05/31/2005 18:50:00 10.1 0.3 10.7 9.1 10 0.4 10.7 8.4 39 3 39 305 0.7 0.2 1.3 0.6 05/31/2005 19:00:00 9.4 0.6 11.1 7.2 9.2 0.8 10.7 7.2 46 4 50 305 0.9 0.3 1.5 0.6 05/31/2005 19:10:00 9.9 0.5 11.1 8.4 9.8 0.6 11.1 8 46 3 40 305 1.3 0.2 2 1 05/31/2005 19:20:00 9.1 0.6 10.7 7.2 9 0.6 10.3 7.2 44 4 42 305 1.3 0.2 2 1 05/31/2005 19:30:00 9.5 0.5 10.7 7.6 9.6 0.5 10.7 7.6 46 4 45 305 1.5 0.1 2 1.3 05/31/2005 19:40:00 9.5 0.5 10.7 7.6 9.5 0.5 10.7 8 45 4 44 305 1.3 0.2 2 1 05/31/2005 19:50:00 9.4 0.6 11.1 7.6 9.5 0.6 11.1 7.6 45 4 44 305 1 0.1 1.5 0.6 05/31/2005 20:00:00 9.5 0.5 10.7 7.6 9.4 0.6 10.7 7.6 45 5 38 305 0.9 0.1 1.3 0.6 05/31/2005 20:10:00 9.8 0.5 11.1 8.4 9.7 0.5 11.1 7.6 47 3 48 305 0.9 0.2 1.5 0.6 05/31/2005 20:20:00 9.3 0.5 10.7 7.6 9.1 0.5 10.7 7.2 45 4 43 305 0.9 0.1 1.3 0.6 05/31/2005 20:30:00 9.3 0.4 10.3 8 9.1 0.6 10.3 7.2 46 4 52 305 1.3 0.1 2 1 05/31/2005 20:40:00 9.2 0.5 10.7 7.2 9.1 0.6 10.7 7.2 46 4 45 305 1.6 0 2.2 1.3 05/31/2005 20:50:00 9.4 0.5 10.3 7.6 9.4 0.5 10.3 7.2 44 4 46 305 1.3 0.1 2 1.3 05/31/2005 21:00:00 9.6 0.5 11.1 8 9.5 0.6 11.1 7.6 45 4 42 305 1.3 0.1 1.7 1 05/31/2005 21:10:00 8.7 0.6 9.9 6.8 8.7 0.7 10.3 6.8 41 6 33 305 1.2 0.1 1.5 1 05/31/2005 21:20:00 8.6 0.6 10.3 6.8 8.6 0.6 10.3 6.8 41 5 36 305 1.3 0.1 1.7 1 05/31/2005 21:30:00 8.4 0.6 10.3 6.8 8.4 0.6 10.3 6.5 43 5 40 305 1.3 0.1 1.7 1 05/31/2005 21:40:00 7.7 0.5 9.1 6.1 7.8 0.6 9.5 6.1 39 6 47 305 1.1 0 1.5 0.8 05/31/2005 21:50:00 7.3 0.5 8.8 6.1 7.3 0.6 8.8 5.3 34 5 39 305 1.2 0.2 1.7 1 05/31/2005 22:00:00 7.3 0.5 8.4 6.1 7.4 0.5 8.4 6.1 35 4 32 305 1.2 0.1 1.5 1 05/31/2005 22:10:00 7 0.3 7.6 6.1 7 0.4 8 5.7 35 4 40 305 1.2 0.1 1.5 1 05/31/2005 22:20:00 7 0.4 8 5.7 7.1 0.4 8.4 5.7 36 4 37 305 1.1 0 1.5 1 05/31/2005 22:30:00 7.5 0.4 8.8 6.5 7.6 0.5 9.1 6.1 35 4 40 305 1.2 0.1 1.5 1 05/31/2005 22:40:00 7.3 0.6 8.8 6.1 7.3 0.7 8.8 5.7 38 6 37 305 1.2 0.1 1.5 1 05/31/2005 22:50:00 7.2 0.4 8.4 6.1 7.2 0.4 8.4 5.7 33 4 32 305 1.2 0.2 1.5 1 05/31/2005 23:00:00 7 0.4 8 5.7 7.1 0.4 8.4 5.7 35 5 38 305 1.2 0.2 1.5 1 05/31/2005 23:10:00 6.9 0.5 8.4 6.1 6.9 0.5 8.4 5.7 39 6 38 305 1.2 0.2 1.7 1 05/31/2005 23:20:00 7.4 0.6 9.1 6.1 7.4 0.6 8.8 6.1 41 5 34 305 1.2 0.2 1.5 1 05/31/2005 23:30:00 7.5 0.6 9.1 5.7 7.6 0.6 8.8 5.7 39 5 45 305 1.2 0.2 1.5 1 05/31/2005 23:40:00 7.4 0.5 8.8 5.7 7.4 0.6 8.8 5.7 38 5 37 305 1.2 0.2 1.5 1 05/31/2005 23:50:00 7.9 0.5 9.1 6.5 7.9 0.5 9.1 6.5 39 4 35 305 1.1 0 1.5 1 06/01/2005 00:00:00 8.2 0.5 9.5 6.8 8.3 0.5 9.5 6.8 39 5 41 305 1 0 1.5 0.8 06/01/2005 00:10:00 8.5 0.7 10.3 6.8 8.5 0.7 10.7 6.5 43 6 44 305 1 0.1 1.3 0.8 06/01/2005 00:20:00 8.2 0.6 9.5 6.5 8.2 0.6 9.5 6.8 45 5 42 305 1 0.1 1.3 0.8 06/01/2005 00:30:00 7.6 0.6 9.1 5.7 7.6 0.6 9.5 6.1 43 5 47 305 1 0 1.3 0.8 06/01/2005 00:40:00 7 0.6 8.8 5.3 7 0.6 8.4 5.3 39 5 30 305 1 0.1 1.3 0.8 06/01/2005 00:50:00 7.5 0.5 8.8 6.1 7.5 0.6 9.1 6.1 40 6 55 305 1 0.1 1.5 0.8 06/01/2005 01:00:00 8.3 0.5 9.9 6.8 8.5 0.5 9.9 7.2 43 5 42 305 1 0.1 1.5 0.8 06/01/2005 01:10:00 8.6 0.5 9.9 6.8 8.6 0.5 9.5 6.8 42 4 38 305 1.1 0.1 1.5 1 06/01/2005 01:20:00 8.3 0.5 9.9 7.2 8.3 0.5 9.9 6.8 41 5 44 305 1 0 1.5 0.8 06/01/2005 01:30:00 8.4 0.5 10.3 7.2 8.4 0.5 9.9 7.2 41 4 42 305 1 0 1.5 0.8 06/01/2005 01:40:00 8.2 0.5 9.5 6.8 8.3 0.4 9.5 7.2 43 4 45 305 1 0 1.5 0.8 06/01/2005 01:50:00 7.9 0.6 9.5 6.5 7.9 0.6 9.5 6.5 41 5 48 305 1 0 1.5 0.8 06/01/2005 02:00:00 6.9 0.4 8 6.1 6.9 0.4 8 6.1 38 4 38 305 1 0 1.5 0.8 06/01/2005 02:10:00 6.6 0.5 8 5.3 6.6 0.5 8 4.9 42 5 40 305 1 0 1.5 0.8 06/01/2005 02:20:00 6.6 0.5 8 5.3 6.5 0.6 8 4.9 42 5 47 305 1 0 1.5 0.8 06/01/2005 02:30:00 6.3 0.5 7.2 4.9 6.2 0.5 7.6 4.9 40 6 44 305 1 0 1.5 0.8 06/01/2005 02:40:00 6.1 0.4 6.8 5.3 6.1 0.4 7.2 4.9 34 4 38 305 0.9 0 1.3 0.8 06/01/2005 02:50:00 6.4 0.4 7.6 5.3 6.4 0.4 7.6 5.3 36 4 36 305 0.9 0 1.3 0.8 06/01/2005 03:00:00 6.5 0.4 7.2 5.7 6.5 0.4 8 5.7 35 4 36 305 0.9 0 1.3 0.8 06/01/2005 03:10:00 6.9 0.5 8.4 5.7 7 0.5 8.8 5.7 39 5 36 305 0.9 0 1.5 0.8 06/01/2005 03:20:00 7.3 0.5 8.8 6.1 7.3 0.5 8.8 5.7 38 5 40 305 1 0 1.5 0.8 06/01/2005 03:30:00 7.2 0.4 8.4 6.1 7.2 0.5 8.4 6.1 38 5 36 305 1 0.1 1.5 0.8 06/01/2005 03:40:00 7.5 0.5 9.1 6.1 7.6 0.5 8.8 5.7 40 5 41 305 0.9 0.1 1.5 0.8 06/01/2005 03:50:00 7.3 0.5 8.8 6.1 7.3 0.5 8.4 6.1 38 3 40 305 0.9 0.1 1.3 0.8 06/01/2005 04:00:00 7.2 0.4 8.4 6.1 7.2 0.4 8.8 6.1 36 4 34 305 0.9 0.2 1.3 0.8 06/01/2005 04:10:00 6.8 0.4 7.6 5.7 6.9 0.4 8 5.7 38 4 33 305 0.9 0.2 1.3 0.8 06/01/2005 04:20:00 7.4 0.4 8.8 6.5 7.4 0.4 8.8 6.1 38 5 41 305 0.9 0.2 1.5 0.6 06/01/2005 04:30:00 8 0.4 9.5 6.8 8 0.4 9.5 6.8 40 4 43 305 0.9 0.2 1.3 0.8 06/01/2005 04:40:00 8.3 0.5 9.5 7.2 8.4 0.4 9.5 7.2 41 4 43 305 1 0.2 1.5 0.8 06/01/2005 04:50:00 8.6 0.6 9.9 6.8 8.7 0.7 9.9 6.8 42 5 41 305 1 0.1 1.3 0.8 06/01/2005 05:00:00 8.3 0.5 9.5 6.8 8.3 0.6 9.9 6.5 43 6 41 305 1 0.1 1.5 0.8 06/01/2005 05:10:00 8 0.5 9.1 6.5 8 0.5 9.1 6.1 39 5 40 305 1 0 1.5 0.8 06/01/2005 05:20:00 7.8 0.4 9.1 6.8 7.8 0.4 9.1 6.8 35 4 35 305 0.9 0.1 1.5 0.8 06/01/2005 05:30:00 7.7 0.4 9.1 6.5 7.7 0.4 9.5 6.8 37 3 38 305 0.9 0.1 1.3 0.6 06/01/2005 05:40:00 8.3 0.5 9.5 6.8 8.3 0.5 9.5 6.8 42 5 36 305 0.9 0.1 1.3 0.6 06/01/2005 05:50:00 8.2 0.6 9.9 6.5 8.3 0.6 10.3 6.5 41 5 52 305 0.9 0.1 1.3 0.6 06/01/2005 06:00:00 8.3 0.5 9.5 6.5 8.2 0.5 9.9 6.5 44 6 43 305 0.9 0.1 1.3 0.6 06/01/2005 06:10:00 8.3 0.5 9.5 6.8 8.3 0.5 9.5 7.2 51 5 44 305 0.9 0 1.3 0.6 06/01/2005 06:20:00 8.4 0.6 10.3 6.5 8.5 0.6 9.9 6.8 47 5 50 305 0.9 0 1.3 0.8 06/01/2005 06:30:00 8.1 0.6 9.9 6.8 8.1 0.7 9.9 6.5 47 6 53 305 0.9 0 1.3 0.8 06/01/2005 06:40:00 8.7 0.6 9.9 6.8 8.8 0.6 10.3 7.2 49 6 50 305 0.9 0 1.5 0.8 06/01/2005 06:50:00 9.2 0.4 10.3 8 9.3 0.4 10.3 7.6 50 3 46 305 0.9 0 1.5 0.8 06/01/2005 07:00:00 9.4 0.5 10.7 8 9.5 0.5 10.7 8.4 48 4 46 305 1.1 0.1 1.5 0.8 06/01/2005 07:10:00 9.4 0.4 10.7 8 9.4 0.4 10.7 8.4 48 4 53 305 1 0.1 1.5 0.8 06/01/2005 07:20:00 9.7 0.4 10.7 8.8 9.7 0.4 11.1 8.4 49 3 53 305 1.1 0.1 1.5 1 06/01/2005 07:30:00 10.4 0.4 11.5 9.5 10.5 0.4 11.5 9.5 53 2 51 305 1.1 0.1 1.5 1 06/01/2005 07:40:00 10.4 0.3 11.1 9.5 10.4 0.4 11.5 9.5 51 2 52 305 1 0 1.5 0.8 06/01/2005 07:50:00 10.8 0.3 11.5 10.3 10.8 0.3 11.8 9.9 54 2 52 305 1 0.1 1.5 0.8 06/01/2005 08:00:00 10.8 0.4 11.8 9.9 10.7 0.5 11.8 9.1 55 2 56 305 1.2 0.1 1.5 1 06/01/2005 08:10:00 9.8 0.4 11.1 8.4 9.8 0.5 11.1 8 53 3 55 305 1.2 0.2 1.5 1 06/01/2005 08:20:00 9.9 0.4 11.1 8.8 10 0.5 11.1 8.8 53 3 53 305 1.3 0.2 1.5 1 06/01/2005 08:30:00 9.5 0.5 10.7 8 9.5 0.6 10.7 7.2 53 3 57 305 1.2 0.2 1.5 1 06/01/2005 08:40:00 9.3 0.4 10.3 7.6 9.2 0.5 10.3 7.2 51 3 52 305 1.2 0.2 1.5 1 06/01/2005 08:50:00 9.5 0.4 10.3 8.4 9.5 0.5 10.7 7.6 52 3 50 305 1.2 0.1 1.5 0.8 06/01/2005 09:00:00 9.3 0.3 9.9 8.4 9.2 0.4 10.3 8 52 2 52 305 1.2 0.2 1.5 1 06/01/2005 09:10:00 9.2 0.3 9.9 8 9.2 0.4 9.9 7.6 53 2 54 305 1.1 0.1 1.5 1 06/01/2005 09:20:00 8.9 0.4 10.3 7.6 8.8 0.4 9.9 6.8 53 3 55 305 1.2 0.2 1.5 1 06/01/2005 09:30:00 9.7 0.4 10.7 8.8 9.6 0.4 10.3 8.4 53 2 58 305 1.2 0.2 1.7 1 06/01/2005 09:40:00 9.3 0.3 10.7 8.8 9.3 0.4 10.3 8.4 50 2 53 305 1.2 0.2 1.5 1 06/01/2005 09:50:00 9.3 0.3 9.9 8.4 9.4 0.3 10.3 8 50 2 50 305 1.2 0.2 1.7 1 06/01/2005 10:00:00 9.4 0.4 10.3 8.4 9.3 0.5 10.3 7.6 51 3 49 305 1.2 0.2 1.7 1 06/01/2005 10:10:00 9.1 0.4 10.3 7.6 9 0.5 9.9 7.6 50 3 54 305 1.3 0.2 1.7 1 06/01/2005 10:20:00 8.4 0.4 9.1 6.8 8.3 0.5 9.1 6.8 46 3 48 305 1.1 0.1 1.5 1 06/01/2005 10:30:00 7.7 0.7 9.1 5.3 7.8 0.6 9.1 5.7 45 5 44 305 0.9 0.1 1.5 0.6 06/01/2005 10:40:00 7.4 0.5 8.8 6.1 7.4 0.5 8.4 5.7 46 5 43 305 1 0.1 1.5 0.6 06/01/2005 10:50:00 7.2 0.4 8 6.1 7.1 0.5 8.4 5.7 41 5 46 305 1 0.1 1.5 0.8 06/01/2005 11:00:00 7.1 0.3 8 6.1 7.1 0.3 8 6.1 38 4 40 305 1 0 1.5 0.8 06/01/2005 11:10:00 7.4 0.2 8 6.8 7.4 0.3 8 6.5 33 2 32 305 0.8 0.1 1.5 0.6 06/01/2005 11:20:00 7.3 0.3 8 6.5 7.3 0.3 8 6.1 37 3 40 305 0.8 0.1 1.5 0.6 06/01/2005 11:30:00 6.8 0.4 7.6 5.7 6.8 0.4 7.6 5.7 42 3 38 305 1 0 1.5 0.8 06/01/2005 11:40:00 6 0.4 6.8 4.9 6.1 0.4 7.6 5.3 37 5 42 305 1 0.1 1.5 0.8 06/01/2005 11:50:00 6.1 0.3 6.8 4.9 6.1 0.3 6.8 5.3 34 3 37 305 1 0 1.5 0.8 06/01/2005 12:00:00 6 0.3 6.8 5.3 6 0.3 6.8 5.3 35 3 32 305 1.1 0.1 1.7 1 06/01/2005 12:10:00 6.2 0.4 7.2 5.3 6.2 0.4 7.6 4.9 35 3 37 305 1.3 0.1 1.7 1 06/01/2005 12:20:00 6.6 0.3 7.2 5.7 6.6 0.3 7.2 5.3 39 3 38 305 1.3 0.1 2 1 06/01/2005 12:30:00 6.7 0.3 7.2 5.7 6.7 0.4 7.2 5.3 41 3 39 305 1.6 0 2 1.5 06/01/2005 12:40:00 6.4 0.4 7.2 5.3 6.4 0.5 7.2 4.9 43 4 44 305 1.4 0.1 2 1.3 06/01/2005 12:50:00 6.4 0.4 7.2 5.3 6.5 0.5 7.6 5.3 41 5 42 305 1.5 0.1 2 1.3 06/01/2005 13:00:00 6.6 0.4 7.6 5.3 6.7 0.5 7.6 4.9 41 4 47 305 1.4 0.2 2 1 06/01/2005 13:10:00 6.6 0.4 7.6 5.7 6.6 0.4 7.6 4.9 40 4 38 305 1.2 0.2 1.5 0.8 06/01/2005 13:20:00 6.6 0.7 8.4 4.6 6.7 0.6 8.4 4.6 41 6 43 305 0.9 0 1.5 0.8 06/01/2005 13:30:00 6.7 0.5 8 5.3 6.8 0.5 8 5.3 46 6 41 305 1.2 0.1 1.7 0.8 06/01/2005 13:40:00 6.4 0.4 7.2 5.3 6.5 0.5 7.6 4.9 46 5 54 305 1.4 0.1 2 1.3 06/01/2005 13:50:00 6.3 0.5 7.2 4.6 6.4 0.6 7.2 4.9 41 4 39 305 1.5 0.1 2.2 1.3 06/01/2005 14:00:00 6.4 0.5 7.6 4.9 6.4 0.4 7.2 4.9 43 4 43 305 1.4 0.2 2.2 1 06/01/2005 14:10:00 6.8 0.4 8 5.7 6.8 0.4 8 5.3 35 4 38 305 1.9 0.2 2.5 1.5 06/01/2005 14:20:00 6.7 0.3 7.2 5.7 6.7 0.4 7.6 4.6 34 3 37 305 1.4 0.2 2 1 06/01/2005 14:30:00 6.8 0.3 7.6 6.1 6.9 0.3 7.6 5.7 37 2 37 305 1.3 0.2 2 1 06/01/2005 14:40:00 6.4 0.3 7.2 5.3 6.4 0.4 7.2 4.6 33 3 37 305 1.6 0.2 2.2 1.3 06/01/2005 14:50:00 6.1 0.3 6.8 5.3 6.1 0.4 6.8 4.6 30 2 36 305 1.4 0.2 2.2 1 06/01/2005 15:00:00 5.8 0.3 6.5 4.6 5.8 0.4 6.5 4.9 32 3 32 305 1.3 0.2 2 1 06/01/2005 15:10:00 6.3 0.3 6.8 5.3 6.4 0.3 7.2 5.3 35 2 35 305 1 0.1 1.5 0.6 06/01/2005 15:20:00 6.4 0.3 6.8 5.3 6.4 0.4 7.2 4.9 36 2 36 305 0.9 0.1 1.5 0.6 06/01/2005 15:30:00 6 0.3 6.5 4.9 6.1 0.4 6.8 4.9 37 3 31 305 0.7 0.2 1.5 0.3 06/01/2005 15:40:00 6 0.3 6.5 4.9 6.1 0.3 6.8 5.3 34 3 37 305 0.6 0.2 1.3 0.3 06/01/2005 15:50:00 6 0.3 6.5 5.3 6.1 0.4 6.8 4.9 37 3 37 305 0.6 0.2 1.3 0.3 06/01/2005 16:00:00 6.1 0.3 6.8 5.7 6.2 0.3 6.8 5.3 34 3 38 305 0.6 0.2 1.3 0.3 06/01/2005 16:10:00 5.4 0.3 6.5 4.6 5.4 0.4 6.1 4.2 30 3 35 305 0.5 0 1 0.3 06/01/2005 16:20:00 5.4 0.3 6.1 4.6 5.4 0.3 6.1 4.6 28 4 27 305 0.6 0.2 1.3 0.3 06/01/2005 16:30:00 5.6 0.3 6.5 4.6 5.5 0.4 6.5 4.2 37 3 42 305 1 0.3 1.7 0.6 06/01/2005 16:40:00 5.7 0.2 6.5 4.9 5.7 0.3 6.5 4.9 31 3 33 305 1.4 0.1 2 1 06/01/2005 16:50:00 5.6 0.4 6.1 4.6 5.6 0.4 6.5 4.2 30 3 28 305 1.3 0.1 2 1 06/01/2005 17:00:00 5.1 0.2 5.7 4.6 5.1 0.3 6.1 4.2 25 3 24 305 1.3 0.1 2 1 06/01/2005 17:10:00 5.2 0.3 6.1 4.2 5.2 0.3 6.1 4.2 21 4 25 305 1.4 0.2 2 1 06/01/2005 17:20:00 4.8 0.3 5.3 3.8 4.9 0.3 5.7 3.8 16 3 18 305 1.1 0 1.5 1 06/01/2005 17:30:00 4.7 0.2 5.3 4.2 4.8 0.3 5.3 3.8 16 2 15 305 0.9 0.2 1.5 0.6 06/01/2005 17:40:00 4.3 0.2 4.9 3.4 4.4 0.3 4.9 3.8 16 3 18 305 0.9 0.2 1.5 0.6 06/01/2005 17:50:00 4 0.3 4.6 3 4.1 0.3 4.9 3.4 13 4 14 305 0.9 0.2 1.5 0.6 06/01/2005 18:00:00 4.3 0.2 4.9 3.8 4.4 0.3 4.9 3.8 19 3 18 305 1 0.2 1.7 0.6 06/01/2005 18:10:00 4.2 0.2 4.6 3.4 4.3 0.3 4.9 3.4 19 3 18 305 1.1 0.1 1.5 0.8 06/01/2005 18:20:00 4.1 0.3 4.9 3.4 4.2 0.3 4.9 3.4 19 3 21 305 1.2 0 1.5 1 06/01/2005 18:30:00 4.1 0.3 4.6 3 4.2 0.3 4.9 3.4 18 4 21 305 1 0 1.3 0.8 06/01/2005 18:40:00 4.1 0.3 4.9 3 4.1 0.3 4.9 3.4 22 6 22 305 1.1 0.1 1.5 0.8 06/01/2005 18:50:00 4.2 0.3 4.9 3 4.3 0.3 4.9 3.4 12 4 12 305 1.2 0 1.5 1 06/01/2005 19:00:00 3.8 0.4 4.6 3 4 0.4 4.9 3 17 4 22 305 1.2 0.1 1.5 0.8 06/01/2005 19:10:00 3.2 0.3 3.8 2.3 3.4 0.3 4.2 2.3 16 7 20 305 0.8 0 1 0.6 06/01/2005 19:20:00 2.9 0.4 3.8 1.9 3.1 0.4 4.2 1.9 14 5 24 305 1 0 1.3 0.8 06/01/2005 19:30:00 2.7 0.4 3.8 1.9 2.9 0.4 3.8 1.9 13 8 13 305 0.9 0 1.3 0.8 06/01/2005 19:40:00 1.9 0.4 3 0.7 2.2 0.4 3.4 1.1 13 11 12 305 0.9 0 1 0.8 06/01/2005 19:50:00 2.2 0.4 3 1.1 2.5 0.4 3.4 1.5 7 7 2 305 0.9 0 1 0.6 06/01/2005 20:00:00 2.4 0.3 3.4 1.5 2.6 0.3 3.8 1.9 10 5 13 305 0.7 0.1 1 0.6 06/01/2005 20:10:00 2.5 0.3 3.4 1.9 2.6 0.3 3.4 1.5 16 6 32 305 0.5 0 0.8 0.6 06/01/2005 20:20:00 2.5 0.4 3 1.1 2.6 0.4 3.4 1.1 17 6 17 305 0.5 0 0.6 0.3 06/01/2005 20:30:00 1.8 0.4 2.6 0.4 2 0.4 3 1.1 27 9 36 305 0.7 0 0.8 0.6 06/01/2005 20:40:00 1.6 0.3 2.6 0.7 1.9 0.3 2.6 0.7 18 8 13 305 0.4 0 0.8 0.3 06/01/2005 20:50:00 0.5 0.3 1.9 0.4 1 0.4 1.9 0.4 31 15 25 305 0.5 0.2 1 0.3 06/01/2005 21:00:00 0.5 0.3 1.5 0.4 0.9 0.3 1.9 0.4 15 2 17 305 1.3 0 1.5 1 06/01/2005 21:10:00 0.5 0.2 1.1 0.4 0.7 0.4 1.9 0.4 346 7 10 305 1.7 0.1 2 1.5 06/01/2005 21:20:00 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 347 2 345 305 1.6 0 2 1.5 06/01/2005 21:30:00 0.4 0.2 1.1 0.4 0.8 0.3 1.5 0.4 343 8 345 305 1.6 0 1.7 1.5 06/01/2005 21:40:00 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 302 2 302 305 2 0.2 2.5 1.7 06/01/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 305 305 2.9 0.2 3.2 2.2 06/01/2005 22:00:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 301 0 301 305 3.9 0.2 4.2 3.2 06/01/2005 22:10:00 0.6 0.3 1.5 0.4 1 0.4 1.5 0.4 304 6 303 305 2.9 0.6 3.9 2.2 06/01/2005 22:20:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 329 14 312 305 1.8 0.2 2.2 1.5 06/01/2005 22:30:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 341 0 305 305 1.3 0.1 1.5 1.3 06/01/2005 22:40:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 341 1 305 305 1.3 0.1 1.5 1.3 06/01/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 1 305 305 1.8 0 2 1.5 06/01/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 1 305 305 1.8 0.1 2.2 1.5 06/01/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 2 305 305 1.9 0 2 1.7 06/01/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 288 58 305 305 2 0 2.2 2 06/01/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 1 305 305 2 0 2.2 2 06/01/2005 23:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 222 1 222 305 1.9 0 2 1.7 06/01/2005 23:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 223 1 221 305 1.7 0 2 1.5 06/02/2005 00:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 223 1 223 305 1.5 0 2.5 1.3 06/02/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 223 2 305 305 1.3 0.1 1.5 1 06/02/2005 00:20:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 223 2 222 305 1 0 1.3 1 06/02/2005 00:30:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 212 6 214 305 1 0.1 1.3 0.8 06/02/2005 00:40:00 0.4 0 0.7 0.4 0.6 0.2 0.7 0.4 208 0 208 305 1.2 0 1.3 1 06/02/2005 00:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 208 0 305 305 1.2 0 1.5 1 06/02/2005 01:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 208 0 305 305 1.4 0 1.5 1.3 06/02/2005 01:10:00 0.6 0.2 1.1 0.4 1.2 0.3 1.9 0.4 208 0 208 305 0.9 0.2 1.3 0.6 06/02/2005 01:20:00 1.3 0.2 1.5 0.7 1.5 0.2 1.9 1.1 221 3 216 305 0.2 0.2 0.6 -0.1 06/02/2005 01:30:00 1.3 0.2 1.5 1.1 1.6 0.2 1.9 1.1 220 2 222 305 -0.1 0 0.1 -0.1 06/02/2005 01:40:00 1.6 0.2 2.3 1.1 1.9 0.2 2.3 1.5 213 4 216 305 0.1 0.1 0.6 -0.1 06/02/2005 01:50:00 2.1 0.2 2.6 1.5 2.3 0.3 3.4 1.9 223 6 201 305 0 0 0.6 -0.4 06/02/2005 02:00:00 2.1 0.2 2.3 1.5 2.2 0.3 3 1.9 227 5 225 305 0 0 0.6 -0.1 06/02/2005 02:10:00 2 0.2 2.3 1.5 2.1 0.2 3 1.9 224 4 230 305 0.1 0.1 0.6 -0.1 06/02/2005 02:20:00 2 0.2 2.3 1.5 2 0.2 2.3 1.9 232 4 226 305 0 0.1 0.6 -0.1 06/02/2005 02:30:00 1.7 0.2 2.3 1.1 1.9 0.2 2.3 1.5 228 4 224 305 0.1 0.1 0.6 0.1 06/02/2005 02:40:00 1.7 0.2 2.3 1.5 1.8 0.2 2.3 1.5 233 6 227 305 0.2 0.1 0.6 0.1 06/02/2005 02:50:00 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.5 246 5 244 305 0.2 0.1 0.6 0.1 06/02/2005 03:00:00 1.6 0.2 1.9 1.1 1.8 0.2 2.3 1.5 238 4 237 305 -0.2 0.1 0.3 -0.4 06/02/2005 03:10:00 1.4 0.3 2.3 0.7 1.8 0.2 2.3 1.1 234 9 244 305 -0.1 0.1 0.6 -0.4 06/02/2005 03:20:00 1 0.3 1.5 0.4 1.5 0.3 2.3 0.7 222 9 214 305 0.1 0.1 0.6 -0.1 06/02/2005 03:30:00 1.3 0.2 1.9 0.7 1.8 0.2 2.3 1.1 202 7 203 305 0.2 0.1 0.6 0.1 06/02/2005 03:40:00 1 0.4 1.9 0.4 1.4 0.3 2.3 0.7 216 8 208 305 0.4 0.3 1 0.1 06/02/2005 03:50:00 0.7 0.3 1.5 0.4 1 0.3 1.9 0.4 224 7 232 305 0.7 0.2 1.3 0.3 06/02/2005 04:00:00 0.5 0.2 1.1 0.4 0.7 0.3 1.5 0.4 230 3 228 305 1 0.2 1.5 0.6 06/02/2005 04:10:00 0.5 0.2 1.5 0.4 0.8 0.3 1.5 0.4 219 15 206 305 1.3 0.1 2 1 06/02/2005 04:20:00 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 222 22 203 305 1.6 0.2 2.2 1.3 06/02/2005 04:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 223 6 305 305 1.8 0.1 2.2 1.5 06/02/2005 04:40:00 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 222 0 222 305 2.2 0.2 2.5 2 06/02/2005 04:50:00 0.4 0.1 0.7 0.4 0.9 0.2 1.5 0.4 222 0 222 305 2.2 0.2 2.7 1.5 06/02/2005 05:00:00 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 220 0 221 305 1.3 0.2 2 1 06/02/2005 05:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 225 9 305 305 1.4 0.2 2.2 1.3 06/02/2005 05:20:00 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 282 17 291 305 1.6 0.3 2.5 1 06/02/2005 05:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 279 15 305 305 1.6 0.2 2.2 1.3 06/02/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 260 0 305 305 2.6 0.4 3.7 1.7 06/02/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 261 0 305 305 3.7 0.3 4.4 3.2 06/02/2005 06:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 272 30 305 305 3.4 0.2 4.4 2.9 06/02/2005 06:10:00 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 358 0 358 305 3.2 0 3.7 2.9 06/02/2005 06:20:00 1.6 0.4 2.3 0.7 1.8 0.4 2.3 1.1 10 4 8 305 2.9 0.2 3.7 2.5 06/02/2005 06:30:00 3 0.6 4.6 1.9 3 0.6 4.6 2.3 17 2 20 305 2.5 0.2 3.2 2.2 06/02/2005 06:40:00 4.7 0.5 6.1 3.4 4.7 0.6 6.5 3 28 5 33 305 2.3 0.2 2.9 2.2 06/02/2005 06:50:00 6.1 0.5 7.2 5.3 6.2 0.5 7.2 5.3 35 2 41 305 1.7 0.4 2.7 1 06/02/2005 07:00:00 6.8 0.4 8 5.7 6.7 0.4 8 5.7 39 2 44 305 1.2 0.1 1.5 1 06/02/2005 07:10:00 7.8 0.5 8.8 6.5 7.9 0.6 8.8 5.7 48 3 48 305 0.7 0.2 1.3 0.6 06/02/2005 07:20:00 8.3 0.4 9.5 7.2 8.2 0.5 9.5 6.1 52 3 53 305 0.3 0 1 0.1 06/02/2005 07:30:00 7.3 0.8 8.8 5.3 7.5 0.8 8.8 5.7 58 5 55 305 0.3 0.1 1 0.1 06/02/2005 07:40:00 6.9 0.7 8.8 4.9 7 0.8 9.1 4.2 60 7 58 305 0.6 0.1 1.3 0.6 06/02/2005 07:50:00 5.9 0.7 7.6 3.8 6 0.8 7.6 3.4 63 10 54 305 0.7 0.2 1.3 0.3 06/02/2005 08:00:00 5.3 1.1 7.6 3 5.2 1 8 3 75 14 97 305 1.2 0.2 1.7 0.6 06/02/2005 08:10:00 6 1 8.8 3.4 5.7 1 9.1 3.4 76 11 67 305 1.9 0.3 2.5 1.3 06/02/2005 08:20:00 6.1 1.3 9.5 3 5.7 1.3 8.8 2.6 83 14 78 305 2.5 0.2 3.2 2 06/02/2005 08:30:00 5.6 1.2 8.4 3 5.3 1 8 2.6 90 12 93 305 2.8 0.2 3.2 2.5 06/02/2005 08:40:00 5 1 7.6 2.6 4.7 1 6.8 2.3 82 21 97 305 2.9 0.1 3.4 2.7 06/02/2005 08:50:00 4.8 0.8 6.8 2.6 4.6 0.8 6.5 2.3 93 13 105 305 3.1 0.2 3.7 2.7 06/02/2005 09:00:00 6 1 8 2.6 6.1 0.8 7.6 3.4 106 10 106 305 2.8 0.2 3.4 2.5 06/02/2005 09:10:00 6.3 1 8.4 3 6.3 0.9 8.4 3 110 12 108 305 2.5 0 2.9 2.2 06/02/2005 09:20:00 6.1 1 8.4 2.6 6.4 0.9 8 3 111 9 108 305 2.4 0.1 2.9 2.2 06/02/2005 09:30:00 6 0.9 7.6 3 6.5 0.7 7.6 4.2 114 10 106 305 2.3 0.1 2.9 2.2 06/02/2005 09:40:00 4.9 1.1 7.2 2.6 5.1 1.1 7.6 2.6 115 12 105 305 2.4 0.2 2.9 2.2 06/02/2005 09:50:00 3.6 1 6.1 0.7 3.8 0.8 6.1 1.5 67 33 65 305 2.5 0.5 3.4 1.5 06/02/2005 10:00:00 4.3 1.1 6.8 0.4 4.3 1.2 7.2 0.4 62 28 99 305 1.8 0.3 2.5 1.3 06/02/2005 10:10:00 4.3 0.7 6.5 2.3 4.3 0.6 6.5 2.6 68 17 54 305 2.3 0.2 2.9 1.7 06/02/2005 10:20:00 3.6 1 5.7 1.5 3.7 1 5.7 1.5 60 22 74 305 2.1 0.2 2.7 1.5 06/02/2005 10:30:00 4.4 0.7 6.5 2.6 4.4 0.7 5.7 2.6 58 17 37 305 2.3 0.2 3.2 2 06/02/2005 10:40:00 3.2 1.3 5.7 0.4 3.3 1.2 6.1 1.1 77 26 54 305 2.6 0.7 4.2 1.7 06/02/2005 10:50:00 3 0.8 4.6 0.7 2.9 0.7 4.6 1.1 83 26 105 305 3.9 0.1 4.4 3.7 06/02/2005 11:00:00 4.1 1.1 7.2 1.5 4.1 1.1 7.6 1.9 81 30 52 305 3.7 0.5 4.4 2.2 06/02/2005 11:10:00 4.9 0.5 6.5 3.4 5.1 0.5 6.8 3.8 48 11 61 305 1.9 0.1 2.2 1.5 06/02/2005 11:20:00 4.7 0.8 7.2 2.3 4.8 0.8 6.8 2.6 45 12 53 305 2 0.2 2.5 1.5 06/02/2005 11:30:00 3.6 0.8 5.3 1.5 3.7 0.7 5.3 1.9 95 13 89 305 3.6 0.6 4.4 2.2 06/02/2005 11:40:00 4.6 0.5 5.7 2.6 4.5 0.4 5.7 3.4 95 8 101 305 4.3 0 4.7 4.2 06/02/2005 11:50:00 4.2 0.7 6.1 2.3 4.2 0.6 5.7 2.6 98 9 101 305 4.5 0.1 4.9 4.4 06/02/2005 12:00:00 4.7 0.6 6.1 3 4.7 0.5 6.1 3.4 105 8 112 305 4.7 0 4.9 4.4 06/02/2005 12:10:00 4.5 0.8 6.1 1.9 4.6 0.7 6.1 2.3 112 10 115 305 4.5 0.1 4.9 4.4 06/02/2005 12:20:00 4.2 0.6 5.7 2.3 4.3 0.5 5.7 2.6 110 9 113 305 4.8 0 5.2 4.7 06/02/2005 12:30:00 3.3 0.7 5.7 1.5 3.6 0.7 5.7 1.5 120 19 124 305 5.1 0 5.4 4.9 06/02/2005 12:40:00 3.3 0.6 5.3 1.9 3.4 0.6 4.6 1.9 117 16 124 305 5.2 0 5.4 5.2 06/02/2005 12:50:00 3.6 0.9 5.7 1.1 3.8 0.7 5.3 2.3 126 19 110 305 5.5 0 5.9 5.4 06/02/2005 13:00:00 3.4 1 5.3 0.4 3.5 1 5.3 0.7 117 20 97 305 5.8 0 5.9 5.6 06/02/2005 13:10:00 3.3 1.3 5.7 0.4 3.5 1.2 5.7 0.4 118 22 108 305 6 0.1 6.4 5.6 06/02/2005 13:20:00 2.8 1.2 4.9 0.4 3 1.1 4.9 0.4 144 30 120 305 6.3 0.2 6.4 5.9 06/02/2005 13:30:00 2.8 1 5.7 0.7 3 0.8 5.3 0.4 145 23 129 305 6 0.2 6.4 5.6 06/02/2005 13:40:00 3.9 1 6.1 0.7 4 0.8 6.1 1.5 113 14 108 305 6 0 6.1 5.9 06/02/2005 13:50:00 3.7 0.8 6.1 1.9 3.8 0.8 5.7 2.3 122 16 114 305 6 0 6.1 5.9 06/02/2005 14:00:00 3.6 0.8 6.1 1.5 3.7 0.8 6.1 1.5 123 17 119 305 6 0 6.1 5.9 06/02/2005 14:10:00 3.5 0.7 5.7 1.9 3.7 0.7 5.3 1.9 121 16 107 305 6 0 6.1 5.9 06/02/2005 14:20:00 3.8 0.8 5.3 1.5 4.1 0.5 5.3 2.6 119 13 110 305 5.6 0.1 5.9 5.4 06/02/2005 14:30:00 4.6 0.8 6.5 1.9 4.6 0.6 6.1 2.6 118 14 139 305 5.5 0 5.6 5.4 06/02/2005 14:40:00 4 0.8 6.1 1.9 4 0.7 5.7 2.3 129 17 121 305 5 0.1 5.4 4.7 06/02/2005 14:50:00 3.3 0.8 4.9 1.5 3.5 0.8 5.3 1.5 125 18 128 305 4.6 0 4.9 4.4 06/02/2005 15:00:00 3.5 0.6 4.9 1.9 3.7 0.5 4.9 2.3 119 12 114 305 4.7 0 4.9 4.4 06/02/2005 15:10:00 2.2 1.1 4.2 0.4 2.3 1.1 4.9 0.4 133 26 159 305 4.5 0.1 4.7 4.4 06/02/2005 15:20:00 3.5 1 4.9 0.7 3.5 0.9 5.3 1.1 121 16 114 305 4.7 0.1 4.9 4.4 06/02/2005 15:30:00 2.6 0.8 4.6 0.7 2.8 0.7 4.2 0.7 114 17 105 305 4.6 0 4.9 4.4 06/02/2005 15:40:00 2.5 0.9 5.7 0.4 2.7 0.6 4.9 1.5 109 18 144 305 4.9 0.1 5.2 4.7 06/02/2005 15:50:00 1.6 0.8 4.2 0.4 1.8 0.7 3.8 0.4 144 41 112 305 4.9 0 5.4 4.7 06/02/2005 16:00:00 2.2 0.6 3.8 0.4 2.4 0.6 3.8 0.7 145 28 127 305 4.7 0 4.9 4.4 06/02/2005 16:10:00 1.6 0.7 3.8 0.4 1.8 0.7 3.4 0.4 162 49 182 305 4.7 0.1 5.2 4.4 06/02/2005 16:20:00 1.6 0.4 2.6 0.4 1.9 0.5 3.4 0.7 205 28 236 305 4.2 0.2 4.9 3.9 06/02/2005 16:30:00 1.4 1 3.8 0.4 1.7 1 4.2 0.4 120 94 357 305 3.7 0.2 4.4 3.2 06/02/2005 16:40:00 2.6 0.9 4.9 0.4 2.6 0.9 4.9 0.4 88 41 103 305 4 0.3 4.7 3.2 06/02/2005 16:50:00 3.1 0.8 4.9 0.4 3.1 0.7 4.6 0.4 79 27 67 305 4.2 0.2 4.9 3.7 06/02/2005 17:00:00 4.4 0.5 5.3 3 4.2 0.5 5.7 3 73 13 86 305 3.4 0.1 3.7 2.9 06/02/2005 17:10:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3.4 65 13 52 305 3 0.2 3.4 2.5 06/02/2005 17:20:00 3.9 0.5 5.3 2.6 3.7 0.5 5.3 2.3 82 9 71 305 3.2 0.1 3.4 2.7 06/02/2005 17:30:00 3.6 0.6 5.3 1.5 3.5 0.5 4.9 1.9 87 12 66 305 3.3 0 3.4 3.2 06/02/2005 17:40:00 3.8 0.6 5.7 2.3 3.7 0.6 6.1 2.3 86 17 87 305 3.3 0.1 3.7 2.9 06/02/2005 17:50:00 4.1 0.5 4.9 2.6 4.1 0.5 4.9 2.6 62 10 84 305 2.9 0.1 3.2 2.7 06/02/2005 18:00:00 4.1 0.5 5.3 2.6 4.4 0.4 5.3 3.4 53 6 44 305 2.5 0.2 3.2 2.2 06/02/2005 18:10:00 3.8 0.5 4.9 2.3 3.9 0.5 4.9 2.3 53 8 50 305 2.5 0 2.7 2.2 06/02/2005 18:20:00 3.7 0.5 5.7 2.6 3.6 0.4 4.9 2.6 58 13 54 305 2.7 0 3.2 2.5 06/02/2005 18:30:00 3.2 0.5 4.6 1.9 3.1 0.5 4.6 1.5 81 13 90 305 3.3 0.2 3.7 2.7 06/02/2005 18:40:00 2.7 0.6 4.2 1.1 2.6 0.6 4.2 1.1 88 19 63 305 3.5 0.2 3.9 2.9 06/02/2005 18:50:00 2.8 0.5 4.6 1.5 2.7 0.5 4.2 1.9 80 18 63 305 3.7 0.1 4.2 3.4 06/02/2005 19:00:00 2.3 0.6 3.8 0.4 2.4 0.5 4.2 1.1 94 26 108 305 3.9 0.1 4.4 3.4 06/02/2005 19:10:00 2.5 0.7 3.8 0.7 2.6 0.6 4.2 1.1 110 17 75 305 4.3 0 4.4 4.2 06/02/2005 19:20:00 2.7 0.4 3.8 1.9 2.7 0.4 3.4 1.5 99 10 81 305 4.2 0 4.4 4.2 06/02/2005 19:30:00 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.5 100 11 99 305 4 0 4.2 3.7 06/02/2005 19:40:00 2.5 0.6 4.6 0.7 2.7 0.5 4.2 1.5 113 10 127 305 4 0 4.4 3.9 06/02/2005 19:50:00 2.3 0.6 4.6 0.7 2.5 0.6 4.2 1.1 145 45 189 305 3.8 0.2 4.2 3.2 06/02/2005 20:00:00 2.7 0.4 3.4 1.9 2.8 0.4 3.4 1.9 228 7 227 305 2.5 0.3 3.2 2.2 06/02/2005 20:10:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 225 5 229 305 2.2 0 2.5 2 06/02/2005 20:20:00 2.3 0.4 3 1.1 2.4 0.3 3 1.5 229 6 225 305 2.1 0 2.2 2 06/02/2005 20:30:00 1.8 0.4 3 0.7 2.1 0.3 2.6 1.1 224 7 232 305 2.1 0 2.5 2 06/02/2005 20:40:00 2.1 0.3 2.6 1.1 2.3 0.3 3 1.5 211 7 210 305 2 0 2.5 2 06/02/2005 20:50:00 1.8 0.3 2.6 1.1 2.1 0.3 3 1.5 199 9 209 305 1.9 0 2.2 1.7 06/02/2005 21:00:00 2 0.3 2.6 1.1 2.1 0.3 2.6 1.5 208 6 203 305 2 0 2.2 1.7 06/02/2005 21:10:00 2.1 0.3 3 1.5 2.2 0.3 3 1.5 217 4 217 305 2 0 2.2 2 06/02/2005 21:20:00 2.7 0.4 3.4 1.5 2.7 0.4 3.4 1.9 220 6 215 305 1.7 0.1 2.2 1.5 06/02/2005 21:30:00 2.9 0.3 3.4 2.3 2.8 0.3 3.4 1.9 220 4 224 305 1.5 0 2 1.3 06/02/2005 21:40:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.9 222 7 231 305 1.3 0.1 1.7 1.3 06/02/2005 21:50:00 2.9 0.3 3.8 1.9 2.8 0.4 3.8 1.9 219 3 217 305 1.2 0.2 1.5 1 06/02/2005 22:00:00 2.5 0.3 3 1.5 2.5 0.3 3 1.5 223 5 219 305 1.2 0.2 1.5 1 06/02/2005 22:10:00 2.5 0.3 3 1.5 2.5 0.3 3 1.5 219 6 221 305 1.1 0.1 1.5 1 06/02/2005 22:20:00 2.7 0.4 3.4 1.1 2.6 0.4 3.4 1.5 220 6 228 305 1 0 1.5 0.8 06/02/2005 22:30:00 2.9 0.3 3.8 1.9 2.8 0.4 3.8 1.9 219 3 217 305 0.9 0 1.3 0.8 06/02/2005 22:40:00 3.1 0.2 3.8 2.3 3.1 0.3 3.8 2.3 218 2 220 305 0.8 0 1.3 0.6 06/02/2005 22:50:00 2.6 0.4 3 1.5 2.5 0.4 3.4 1.5 211 5 212 305 0.9 0.1 1.3 0.6 06/02/2005 23:00:00 3 0.2 3.4 2.3 3.1 0.2 3.4 2.3 203 3 204 305 0.8 0.1 1.3 0.6 06/02/2005 23:10:00 2.8 0.4 3.4 1.9 2.8 0.5 3.4 1.5 206 8 197 305 0.7 0.1 1.3 0.6 06/02/2005 23:20:00 2.8 0.4 3.4 1.5 2.8 0.4 3.4 1.5 215 6 221 305 0.9 0.1 1.3 0.6 06/02/2005 23:30:00 3 0.3 3.8 1.9 2.9 0.3 3.4 1.9 209 5 198 305 0.7 0.2 1.3 0.6 06/02/2005 23:40:00 2.7 0.2 3.4 2.3 2.8 0.3 3.4 1.9 203 5 204 305 0.7 0.2 1.3 0.6 06/02/2005 23:50:00 2.4 0.2 3 1.9 2.5 0.3 3 1.9 205 3 204 305 0.6 0.2 1 0.6 06/03/2005 00:00:00 2.6 0.2 3 2.3 2.7 0.3 3 1.5 205 2 204 305 0.6 0.1 1 0.3 06/03/2005 00:10:00 2.1 0.3 2.6 1.1 2.2 0.4 3 1.1 214 6 210 305 0.5 0 1 0.3 06/03/2005 00:20:00 1.9 0.3 2.6 1.1 1.9 0.3 2.6 1.5 220 5 221 305 0.5 0 1 0.3 06/03/2005 00:30:00 1.9 0.3 2.3 1.1 2 0.3 2.6 1.1 208 5 215 305 0.5 0 1 0.3 06/03/2005 00:40:00 1.8 0.3 2.3 1.1 2 0.3 2.6 1.1 208 5 205 305 0.5 0 1 0.3 06/03/2005 00:50:00 1.1 0.3 1.9 0.4 1.3 0.3 1.9 0.7 218 3 215 305 0.5 0 1 0.3 06/03/2005 01:00:00 1.3 0.4 1.9 0.4 1.5 0.3 2.3 0.7 217 4 221 305 0.5 0 1 0.3 06/03/2005 01:10:00 1.5 0.2 1.9 1.1 1.7 0.2 2.3 1.1 207 2 210 305 0.4 0 1 0.3 06/03/2005 01:20:00 1.4 0.2 1.9 1.1 1.6 0.2 1.9 1.1 204 0 205 305 0.5 0 1 0.3 06/03/2005 01:30:00 1.6 0.2 1.9 1.5 1.9 0.1 2.3 1.5 205 0 205 305 0.4 0 1 0.3 06/03/2005 01:40:00 1.8 0.2 2.3 1.1 2 0.2 2.6 1.1 209 4 207 305 0.4 0 0.8 0.3 06/03/2005 01:50:00 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.5 210 3 215 305 0.4 0 0.8 0.3 06/03/2005 02:00:00 2.6 0.2 3 2.3 2.7 0.2 3 2.3 201 2 201 305 0.4 0 0.8 0.3 06/03/2005 02:10:00 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.3 196 2 194 305 0.4 0 0.8 0.3 06/03/2005 02:20:00 2.5 0.3 3 1.5 2.6 0.3 3.4 1.9 195 1 199 305 0.4 0 0.6 0.3 06/03/2005 02:30:00 1.6 0.2 2.3 0.7 1.9 0.3 2.3 1.1 188 5 194 305 0.4 0 0.8 0.3 06/03/2005 02:40:00 0.8 0.4 1.5 0.4 1.2 0.4 1.9 0.4 182 0 183 305 0.4 0 0.8 0.3 06/03/2005 02:50:00 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 191 9 305 305 0.4 0 0.8 0.3 06/03/2005 03:00:00 0.4 0 0.7 0.4 0.7 0.2 1.1 0.4 204 0 204 305 0.4 0 0.8 0.3 06/03/2005 03:10:00 0.5 0.2 1.1 0.4 0.9 0.3 1.5 0.4 204 1 205 305 0.4 0 0.8 0.3 06/03/2005 03:20:00 0.8 0.3 1.5 0.4 1.4 0.2 1.9 0.7 187 5 194 305 0.4 0 0.8 0.3 06/03/2005 03:30:00 0.8 0.2 1.1 0.4 1.3 0.2 1.9 1.1 188 3 194 305 0.4 0 0.8 0.3 06/03/2005 03:40:00 0.4 0.1 0.7 0.4 0.9 0.3 1.5 0.4 186 0 186 305 0.5 0 0.8 0.3 06/03/2005 03:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 186 0 305 305 0.5 0 1 0.3 06/03/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 186 0 305 305 0.5 0 1 0.3 06/03/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 163 26 305 305 0.6 0.1 1 0.6 06/03/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 131 0 305 305 0.6 0.1 1 0.6 06/03/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 131 0 305 305 0.6 0.2 1 0.6 06/03/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 131 0 305 305 0.6 0.1 1 0.6 06/03/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 131 0 305 305 0.6 0.1 1 0.6 06/03/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 121 27 305 305 0.7 0.1 1 0.6 06/03/2005 05:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 41 6 305 305 0.6 0.1 1 0.6 06/03/2005 05:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 35 0 305 305 0.6 0.1 1 0.6 06/03/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 0.6 0.1 1 0.6 06/03/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 305 305 0.6 0.1 1 0.6 06/03/2005 05:50:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 35 0 305 305 0.6 0 1 0.6 06/03/2005 06:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 35 0 305 305 0.6 0.1 1 0.6 06/03/2005 06:10:00 0.4 0.1 0.7 0.4 0.7 0.3 1.5 0.4 36 1 35 305 0.6 0.1 1 0.6 06/03/2005 06:20:00 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 44 0 305 305 0.7 0.1 1 0.6 06/03/2005 06:30:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 44 0 305 305 0.7 0 1.3 0.6 06/03/2005 06:40:00 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 44 0 305 305 0.8 0 1.3 0.6 06/03/2005 06:50:00 0.4 0.1 1.1 0.4 1.1 0.2 1.5 0.7 44 0 44 305 0.8 0 1.3 0.6 06/03/2005 07:00:00 1 0.2 1.5 0.4 1.5 0.2 1.9 1.1 42 0 42 305 0.9 0 1.5 0.6 06/03/2005 07:10:00 1.1 0.2 1.5 0.7 1.5 0.2 1.9 1.1 42 0 42 305 0.9 0 1.5 0.8 06/03/2005 07:20:00 1 0.2 1.5 0.7 1.5 0.2 1.9 1.1 41 1 42 305 0.9 0 1.5 0.8 06/03/2005 07:30:00 1.2 0.2 1.5 0.7 1.6 0.2 1.9 1.1 40 0 40 305 0.9 0 1.3 0.8 06/03/2005 07:40:00 1.1 0.2 1.5 0.7 1.7 0.2 1.9 1.1 40 0 40 305 0.9 0 1.3 0.8 06/03/2005 07:50:00 0.9 0.2 1.5 0.4 1.7 0.2 1.9 1.1 36 4 40 305 0.9 0 1.3 0.8 06/03/2005 08:00:00 1.3 0.2 1.5 0.7 1.9 0.2 2.3 1.5 33 1 32 305 1 0.1 1.5 0.8 06/03/2005 08:10:00 1.3 0.2 1.9 1.1 1.8 0.2 2.3 1.5 41 1 41 305 1 0 1.5 0.8 06/03/2005 08:20:00 1.2 0.3 1.5 0.4 1.7 0.2 2.3 0.7 39 3 41 305 1 0.1 1.5 0.8 06/03/2005 08:30:00 0.5 0.2 1.1 0.4 1.1 0.2 1.5 0.7 33 0 32 305 1.1 0 1.5 1 06/03/2005 08:40:00 0.5 0.2 1.5 0.4 1.2 0.2 1.9 0.7 27 3 25 305 1.1 0.1 1.5 1 06/03/2005 08:50:00 0.4 0.2 1.1 0.4 1.1 0.2 1.9 0.4 27 3 30 305 1.1 0.1 1.5 1 06/03/2005 09:00:00 0.4 0 0.7 0.4 0.8 0.3 1.5 0.4 12 4 11 305 1.2 0.1 1.5 1 06/03/2005 09:10:00 0.5 0.2 1.5 0.4 0.8 0.4 1.5 0.4 20 7 25 305 1.2 0.1 1.5 1 06/03/2005 09:20:00 0.8 0.5 1.9 0.4 1.2 0.5 2.3 0.4 26 14 30 305 1.4 0 2 1.3 06/03/2005 09:30:00 1.2 0.4 1.9 0.4 1.6 0.3 2.3 0.7 37 9 49 305 1.4 0 2 1.3 06/03/2005 09:40:00 1.7 0.5 2.6 0.4 1.9 0.4 3 1.1 47 7 42 305 1.4 0 1.7 1.3 06/03/2005 09:50:00 2 0.2 2.3 1.5 2.4 0.2 3 1.9 49 4 53 305 1.5 0 2 1.3 06/03/2005 10:00:00 2.5 0.3 3 1.9 2.7 0.3 3.4 1.9 48 3 46 305 1.4 0 1.7 1.3 06/03/2005 10:10:00 2.6 0.2 3 1.9 2.8 0.2 3.4 2.3 45 2 49 305 1.5 0 2 1.3 06/03/2005 10:20:00 2.5 0.2 3 1.9 2.7 0.2 3 1.9 45 2 43 305 1.6 0 2 1.5 06/03/2005 10:30:00 2.4 0.3 3 1.5 2.5 0.3 3.4 1.9 49 4 53 305 1.6 0 2.2 1.5 06/03/2005 10:40:00 2.3 0.4 3 1.5 2.5 0.3 3 1.5 50 6 51 305 1.6 0 2.2 1.5 06/03/2005 10:50:00 2.9 0.4 3.8 1.5 2.9 0.4 3.8 1.9 51 5 58 305 1.7 0.1 2.2 1.5 06/03/2005 11:00:00 3.2 0.4 3.8 2.3 3.2 0.4 4.2 2.3 48 5 37 305 1.7 0.1 2.2 1.5 06/03/2005 11:10:00 3.6 0.2 4.2 2.6 3.7 0.3 4.6 2.6 46 3 49 305 1.7 0.1 2.2 1.5 06/03/2005 11:20:00 3.7 0.2 4.2 3 3.9 0.3 4.6 2.6 45 2 50 305 1.7 0.1 2.2 1.5 06/03/2005 11:30:00 4 0.3 4.9 3 4 0.4 4.9 2.6 49 3 58 305 1.9 0.2 2.2 1.5 06/03/2005 11:40:00 4.2 0.3 4.9 3 4.1 0.4 4.9 3 48 4 45 305 1.9 0.2 2.5 1.5 06/03/2005 11:50:00 4.3 0.5 5.3 3 4.3 0.5 5.3 2.6 53 5 52 305 1.8 0.2 2.2 1.5 06/03/2005 12:00:00 5.9 0.4 6.8 4.9 5.8 0.5 6.8 3.8 60 2 61 305 2 0.2 2.7 1.5 06/03/2005 12:10:00 5.9 0.5 6.8 4.6 5.8 0.5 6.8 4.2 64 5 64 305 2.3 0.3 2.9 2 06/03/2005 12:20:00 6.1 0.5 7.6 4.6 6 0.6 7.2 4.6 69 6 66 305 2.4 0.1 3.2 2.2 06/03/2005 12:30:00 6.3 0.6 7.6 4.6 5.9 0.5 7.2 4.2 75 6 76 305 2.8 0.1 3.4 2.5 06/03/2005 12:40:00 5.7 0.6 7.2 4.2 5.5 0.5 6.8 4.2 74 8 78 305 3 0.2 3.7 2.7 06/03/2005 12:50:00 5.3 0.6 7.2 3.8 5.2 0.6 6.8 3.8 68 9 60 305 3.1 0 3.4 2.9 06/03/2005 13:00:00 5.2 0.4 6.1 4.2 5.2 0.5 6.1 3.8 49 4 49 305 2.5 0.2 3.2 2.2 06/03/2005 13:10:00 4.7 0.4 5.3 3 4.7 0.4 5.7 3.4 47 4 50 305 2.5 0.1 2.9 2.2 06/03/2005 13:20:00 4.6 0.5 5.3 2.6 4.7 0.5 5.7 3 46 5 45 305 2.5 0.1 2.9 2.2 06/03/2005 13:30:00 4.4 0.3 5.3 3.8 4.4 0.4 5.3 3.4 34 5 54 305 2.5 0 3.2 2.2 06/03/2005 13:40:00 4.1 0.4 5.3 3 4.2 0.4 5.3 3 34 9 42 305 2.5 0.1 2.9 2.2 06/03/2005 13:50:00 4.5 0.5 5.3 3 4.6 0.5 5.7 3.4 41 5 40 305 2.5 0 3.2 2.2 06/03/2005 14:00:00 4.4 0.4 5.3 3 4.5 0.4 5.7 3 45 5 50 305 2.6 0.2 3.4 2.2 06/03/2005 14:10:00 5.1 0.3 5.7 3.8 5.1 0.4 5.7 4.2 44 3 58 305 2.8 0.1 3.2 2.5 06/03/2005 14:20:00 3.7 0.5 4.9 2.6 3.9 0.5 4.9 3 43 6 41 305 2.7 0.2 3.4 2.5 06/03/2005 14:30:00 3.1 0.5 4.2 1.9 3.3 0.5 4.6 2.3 41 7 34 305 2.8 0.1 3.4 2.5 06/03/2005 14:40:00 2.6 0.6 3.8 0.4 2.7 0.6 3.8 1.1 36 13 43 305 2.8 0.1 3.4 2.5 06/03/2005 14:50:00 2.5 0.5 3.8 1.1 2.7 0.5 3.8 1.5 36 9 37 305 2.8 0.1 3.2 2.5 06/03/2005 15:00:00 2.7 0.5 4.2 1.1 2.8 0.5 4.2 1.5 38 7 40 305 2.8 0.1 3.2 2.5 06/03/2005 15:10:00 3.3 0.4 4.2 2.3 3.5 0.5 4.6 2.6 37 8 36 305 2.8 0.1 3.2 2.7 06/03/2005 15:20:00 4.4 0.5 5.3 2.6 4.3 0.7 5.3 1.9 39 5 37 305 2.9 0.2 3.4 2.7 06/03/2005 15:30:00 4.4 0.4 5.3 3 4.3 0.5 5.7 3 39 4 41 305 2.9 0.1 3.2 2.7 06/03/2005 15:40:00 4.5 0.3 5.3 3.4 4.4 0.5 5.3 3 41 3 41 305 2.8 0.1 3.2 2.5 06/03/2005 15:50:00 4.2 0.5 5.3 3 4.2 0.5 5.3 3 49 6 42 305 2.8 0 3.2 2.7 06/03/2005 16:00:00 4.7 0.3 5.3 3.4 4.7 0.4 5.3 3.4 50 4 54 305 2.6 0 3.2 2.5 06/03/2005 16:10:00 4.7 0.4 5.7 3.8 4.8 0.4 6.1 3.8 49 4 46 305 2.7 0 3.2 2.5 06/03/2005 16:20:00 4.7 0.4 6.1 3.8 5 0.4 6.1 3.8 51 4 55 305 2.7 0 3.2 2.5 06/03/2005 16:30:00 4.2 0.7 5.3 2.6 4.3 0.7 5.7 2.6 54 7 51 305 3.1 0.1 3.7 2.7 06/03/2005 16:40:00 5 0.5 5.7 3 5.1 0.5 6.1 3.4 47 5 47 305 2.9 0.2 3.7 2.7 06/03/2005 16:50:00 5.5 0.3 6.5 4.2 5.7 0.4 6.5 4.6 46 4 39 305 2.5 0.1 2.9 2.2 06/03/2005 17:00:00 5.3 0.4 6.1 4.2 5.3 0.4 6.1 4.2 47 4 50 305 2.5 0.1 3.2 2.2 06/03/2005 17:10:00 5.2 0.4 6.1 3.8 5.3 0.4 6.1 4.2 47 4 46 305 2.6 0 2.9 2.2 06/03/2005 17:20:00 5.5 0.4 6.1 4.2 5.6 0.4 6.5 4.2 44 3 44 305 2.6 0.1 3.2 2.2 06/03/2005 17:30:00 5.7 0.4 6.5 4.6 5.6 0.5 6.8 4.2 44 3 42 305 2.6 0 3.2 2.5 06/03/2005 17:40:00 6.2 0.3 6.8 5.3 6.1 0.5 6.8 4.6 47 2 47 305 2.6 0 3.2 2.2 06/03/2005 17:50:00 6 0.4 6.8 4.6 5.9 0.5 6.8 4.6 48 2 50 305 2.6 0 3.2 2.2 06/03/2005 18:00:00 6.1 0.2 6.8 5.3 6.2 0.4 6.8 4.9 48 3 51 305 2.5 0.2 2.9 2.2 06/03/2005 18:10:00 6.2 0.2 6.8 5.7 6.3 0.3 6.8 4.9 50 2 51 305 2.5 0.1 2.9 2.2 06/03/2005 18:20:00 6.1 0.3 6.5 4.9 6.2 0.4 6.8 4.6 50 3 53 305 2.3 0.1 2.7 2.2 06/03/2005 18:30:00 6 0.3 6.5 4.9 6 0.4 6.8 4.6 48 2 45 305 2.4 0.1 2.9 2.2 06/03/2005 18:40:00 5.8 0.3 6.5 4.9 5.9 0.4 6.5 4.2 45 2 45 305 2.3 0.1 2.9 2.2 06/03/2005 18:50:00 5.9 0.2 6.5 5.3 6 0.3 6.8 4.9 45 2 50 305 2.4 0.2 3.2 2 06/03/2005 19:00:00 6.2 0.4 6.8 4.9 6.1 0.5 7.2 4.6 45 2 48 305 2.3 0.1 2.9 2.2 06/03/2005 19:10:00 6.3 0.3 6.8 5.7 6.4 0.4 7.2 4.9 46 2 46 305 2.2 0.1 2.7 2 06/03/2005 19:20:00 6.5 0.3 6.8 5.7 6.5 0.4 7.2 5.3 47 2 46 305 2.2 0.1 2.7 2 06/03/2005 19:30:00 6.6 0.2 7.2 6.1 6.7 0.3 7.2 5.7 50 1 51 305 2.1 0 2.7 2 06/03/2005 19:40:00 6.5 0.3 7.2 6.1 6.7 0.3 7.2 5.7 49 2 53 305 2 0 2.5 2 06/03/2005 19:50:00 6.2 0.2 6.8 5.3 6.4 0.2 6.8 5.7 48 2 47 305 1.9 0.1 2.2 1.5 06/03/2005 20:00:00 6.4 0.2 6.8 5.7 6.6 0.2 7.2 6.1 48 1 48 305 1.9 0.1 2.2 1.5 06/03/2005 20:10:00 6.2 0.4 6.8 4.9 6.4 0.3 7.2 5.3 50 3 53 305 1.9 0.1 2.2 1.7 06/03/2005 20:20:00 5.3 0.6 6.5 3.4 5.7 0.6 6.8 4.2 53 4 52 305 1.9 0.1 2.2 1.7 06/03/2005 20:30:00 4.4 0.4 5.3 3 4.8 0.4 5.7 3.8 53 5 57 305 1.9 0.1 2.5 1.7 06/03/2005 20:40:00 3.1 1.6 6.1 0.4 3.3 1.4 5.7 0.7 98 49 57 305 2.3 0.3 2.9 2 06/03/2005 20:50:00 1.5 1 4.2 0.4 1.9 1.1 4.6 0.4 142 94 29 305 2.8 0.2 3.2 2.2 06/03/2005 21:00:00 3.6 0.5 4.6 2.3 4 0.5 4.9 2.6 48 8 45 305 1.8 0.2 2.5 1.5 06/03/2005 21:10:00 3.4 0.7 4.6 1.5 3.6 0.7 4.9 1.5 39 10 42 305 1.7 0.1 2.2 1.5 06/03/2005 21:20:00 3.2 0.5 4.6 1.1 3.5 0.5 4.9 2.3 48 7 45 305 1.7 0.1 2.2 1.5 06/03/2005 21:30:00 3.9 0.3 4.9 3 4.1 0.3 4.9 3 47 5 50 305 1.6 0 2 1.3 06/03/2005 21:40:00 3.6 0.4 4.6 2.3 3.8 0.4 4.6 2.3 53 6 56 305 1.4 0.1 2 1.3 06/03/2005 21:50:00 3.1 0.4 4.2 2.3 3.4 0.4 4.6 2.3 51 9 62 305 1.4 0.1 2 1.3 06/03/2005 22:00:00 2.9 0.5 4.2 1.9 3.3 0.5 4.6 2.3 47 7 43 305 1.4 0.1 2 1.3 06/03/2005 22:10:00 2 1 3.8 0.4 2.5 0.8 3.8 0.7 51 13 44 305 1.4 0.1 2 1.3 06/03/2005 22:20:00 1.1 0.6 3 0.4 1.7 0.5 3 0.4 41 15 36 305 1.7 0.2 2.2 1.3 06/03/2005 22:30:00 1.9 0.7 3.4 0.4 2.4 0.6 3.8 1.1 41 11 53 305 1.6 0.1 2.2 1.3 06/03/2005 22:40:00 2.6 0.8 4.2 0.4 3 0.6 4.2 1.1 45 12 58 305 1.4 0.1 2 1.3 06/03/2005 22:50:00 3.4 0.3 4.2 2.3 3.7 0.3 4.6 2.6 45 5 38 305 1.3 0.1 2 1.3 06/03/2005 23:00:00 3.1 0.3 3.8 2.6 3.3 0.3 3.8 2.6 44 6 40 305 1.3 0.1 2 1.3 06/03/2005 23:10:00 2.6 0.4 3 1.5 2.8 0.3 3.4 1.9 52 5 45 305 1.3 0.1 1.5 1 06/03/2005 23:20:00 1.8 0.3 2.6 0.7 2.3 0.3 3 1.1 48 9 59 305 1.3 0.1 1.5 1 06/03/2005 23:30:00 1.5 0.6 2.3 0.4 2.1 0.5 3 0.7 43 9 44 305 1.3 0.1 1.5 1.3 06/03/2005 23:40:00 1.3 0.5 2.6 0.4 2 0.3 3 1.5 26 9 28 305 1.3 0.1 1.5 1.3 06/03/2005 23:50:00 2.4 0.3 3 1.5 2.7 0.3 3.4 1.9 42 7 33 305 1.2 0.1 1.5 1 06/04/2005 00:00:00 2.7 0.2 3.4 1.9 3 0.3 3.4 2.3 39 4 40 305 1.3 0.1 2 1 06/04/2005 00:10:00 1.3 0.9 3 0.4 1.7 0.8 3.4 0.4 63 18 34 305 1.3 0 2 1.3 06/04/2005 00:20:00 2.7 0.4 3.4 1.5 2.9 0.4 3.8 1.5 58 6 56 305 1.4 0 1.7 1.3 06/04/2005 00:30:00 2.4 0.2 3 1.9 2.6 0.3 3 1.9 59 4 50 305 1.3 0 1.7 1.3 06/04/2005 00:40:00 2.1 0.4 2.6 1.1 2.3 0.4 3 1.5 65 7 60 305 1.3 0 1.7 1.3 06/04/2005 00:50:00 1.4 0.3 2.3 0.7 1.8 0.2 2.3 1.1 67 8 70 305 1.4 0 1.7 1.3 06/04/2005 01:00:00 1.6 0.4 2.6 0.7 2 0.4 2.6 1.1 60 8 43 305 1.4 0 1.7 1.3 06/04/2005 01:10:00 1.4 0.5 2.6 0.4 1.7 0.6 2.6 0.4 61 11 67 305 1.4 0 2 1.3 06/04/2005 01:20:00 1.3 0.4 2.3 0.4 1.7 0.4 2.6 0.4 47 15 62 305 1.4 0 2 1.3 06/04/2005 01:30:00 1 0.5 2.3 0.4 1.6 0.4 2.6 0.7 30 8 42 305 1.5 0 2 1.3 06/04/2005 01:40:00 2.1 0.4 3 1.1 2.4 0.3 3 1.5 37 6 45 305 1.5 0 2 1.3 06/04/2005 01:50:00 2 0.4 2.6 0.7 2.3 0.3 3 1.5 48 12 46 305 1.4 0 2 1.3 06/04/2005 02:00:00 0.7 0.6 2.3 0.4 1.3 0.7 2.6 0.4 47 24 49 305 1.4 0 2 1.3 06/04/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 17 305 305 1.5 0 2 1.3 06/04/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 345 0 305 305 1.5 0 2 1.3 06/04/2005 02:30:00 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 14 32 62 305 1.5 0 2 1.3 06/04/2005 02:40:00 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 47 1 305 305 1.5 0 2 1.3 06/04/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 305 305 1.5 0 2 1.3 06/04/2005 03:00:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 37 21 305 305 1.5 0 2 1.3 06/04/2005 03:10:00 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 15 6 305 305 1.5 0 2 1.3 06/04/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 16 0 305 305 1.5 0 2 1.3 06/04/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11 17 305 305 1.5 0 2 1.3 06/04/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 311 0 305 305 1.5 0 2 1.3 06/04/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 311 0 305 305 1.4 0 2 1.3 06/04/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 311 0 305 305 1.4 0 2 1.3 06/04/2005 04:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 250 38 305 305 1.4 0 2 1.3 06/04/2005 04:20:00 0.4 0.2 1.1 0.4 0.9 0.4 1.9 0.4 183 1 183 305 1.4 0 2 1.3 06/04/2005 04:30:00 0.7 0.3 1.5 0.4 1.3 0.3 1.9 0.7 195 12 186 305 1.3 0 1.7 1.3 06/04/2005 04:40:00 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 223 7 305 305 1.2 0.1 1.7 1 06/04/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 228 0 305 305 1.1 0 1.5 1 06/04/2005 05:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 228 0 305 305 1.2 0.1 1.5 1 06/04/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 228 0 305 305 1.2 0.1 1.5 1 06/04/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 228 0 305 305 1.2 0.1 1.5 1 06/04/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 228 0 305 305 1.3 0.1 1.7 1.3 06/04/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 228 0 305 305 1.4 0 2 1.3 06/04/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 228 0 305 305 1.5 0 2 1.3 06/04/2005 06:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 248 33 305 305 1.6 0.1 2 1.5 06/04/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 305 305 1.7 0.1 2.2 1.5 06/04/2005 06:20:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 296 51 305 305 1.7 0.2 2.2 1.5 06/04/2005 06:30:00 0.4 0.1 0.7 0.4 1 0.2 1.5 0.4 220 10 207 305 1.6 0 2.2 1.5 06/04/2005 06:40:00 0.6 0.2 1.1 0.4 1.3 0.2 1.9 0.7 199 2 201 305 1.6 0 2 1.5 06/04/2005 06:50:00 1.3 0.5 2.3 0.4 1.9 0.4 2.6 0.7 197 6 188 305 1.6 0 2 1.5 06/04/2005 07:00:00 1.8 0.4 2.6 0.4 2.4 0.3 3 1.9 186 3 188 305 1.7 0.1 2.2 1.5 06/04/2005 07:10:00 1.5 0.4 2.3 0.4 2.4 0.3 3.4 1.9 187 9 196 305 1.9 0.1 2.2 1.5 06/04/2005 07:20:00 1.7 0.5 2.6 0.4 2.8 0.3 3.4 1.9 179 6 182 305 2 0 2.5 2 06/04/2005 07:30:00 2 0.4 3 1.1 2.7 0.3 3.4 1.9 180 9 183 305 2.2 0.2 2.7 2 06/04/2005 07:40:00 1.6 0.3 2.6 0.7 2.3 0.3 3 1.5 185 9 186 305 2.7 0.2 3.4 2.2 06/04/2005 07:50:00 1 0.5 2.3 0.4 1.8 0.4 2.6 1.1 181 5 191 305 2.9 0.1 3.2 2.7 06/04/2005 08:00:00 0.4 0.2 1.1 0.4 1.1 0.4 1.9 0.4 180 6 182 305 3.1 0.1 3.4 2.9 06/04/2005 08:10:00 0.4 0.2 1.9 0.4 0.7 0.5 1.9 0.4 122 98 46 305 3.3 0.1 3.7 2.9 06/04/2005 08:20:00 0.8 0.5 2.3 0.4 1.6 0.6 3 0.4 13 22 2 305 2.9 0.2 3.4 2.5 06/04/2005 08:30:00 1.1 0.7 2.6 0.4 2 0.5 3 1.1 12 9 357 305 2.4 0.2 3.2 2.2 06/04/2005 08:40:00 1.2 0.6 2.3 0.4 2.1 0.4 3 1.1 12 7 6 305 2.3 0.2 2.7 2.2 06/04/2005 08:50:00 1.2 0.6 2.3 0.4 1.9 0.4 2.6 1.1 13 9 355 305 2.3 0.1 2.7 2.2 06/04/2005 09:00:00 0.7 0.5 2.3 0.4 1.5 0.5 2.6 0.7 38 6 43 305 2.3 0.1 2.9 2.2 06/04/2005 09:10:00 0.9 0.5 2.3 0.4 1.6 0.5 2.6 0.4 22 13 29 305 2.6 0 2.9 2.5 06/04/2005 09:20:00 0.4 0.2 1.9 0.4 0.9 0.5 2.3 0.4 69 41 45 305 2.8 0.1 3.4 2.7 06/04/2005 09:30:00 0.4 0.2 1.9 0.4 0.9 0.4 2.3 0.4 146 94 70 305 3.5 0.2 4.2 2.9 06/04/2005 09:40:00 0.9 0.5 2.3 0.4 1.5 0.5 2.3 0.7 232 9 239 305 3.3 0.2 3.9 2.9 06/04/2005 09:50:00 1 0.5 1.9 0.4 1.6 0.4 2.6 0.7 231 13 225 305 3.2 0.1 3.7 2.9 06/04/2005 10:00:00 0.9 0.5 2.3 0.4 1.6 0.4 2.6 0.7 223 10 229 305 3 0.1 3.4 2.9 06/04/2005 10:10:00 1.4 0.5 2.6 0.4 2.1 0.4 3 1.1 224 6 217 305 3 0.1 3.4 2.9 06/04/2005 10:20:00 1.2 0.4 1.9 0.4 1.9 0.3 2.6 1.1 220 8 228 305 3.1 0 3.4 2.9 06/04/2005 10:30:00 1 0.5 1.9 0.4 1.8 0.4 2.6 0.7 194 14 191 305 3.3 0.1 3.7 2.9 06/04/2005 10:40:00 0.8 0.4 1.9 0.4 1.6 0.3 2.3 0.7 191 10 192 305 3.4 0.1 3.7 3.2 06/04/2005 10:50:00 1.3 0.5 3 0.4 1.8 0.4 2.6 0.7 219 15 224 305 3.3 0 3.7 3.2 06/04/2005 11:00:00 1.6 0.5 2.6 0.4 1.8 0.5 3 0.7 241 23 221 305 3.5 0.2 4.2 3.2 06/04/2005 11:10:00 1.8 0.8 3.4 0.4 2 0.7 3.4 0.4 231 16 216 305 3.8 0 4.2 3.7 06/04/2005 11:20:00 1.8 0.4 2.6 0.7 1.9 0.4 3 0.7 243 16 221 305 3.6 0 3.7 3.4 06/04/2005 11:30:00 1.3 0.5 2.6 0.4 1.6 0.4 2.3 0.7 241 12 246 305 3.8 0.1 4.2 3.4 06/04/2005 11:40:00 0.9 0.6 2.3 0.4 1.1 0.5 2.3 0.4 240 22 243 305 4.4 0.1 4.7 4.2 06/04/2005 11:50:00 2 0.4 3 1.1 2.1 0.3 2.6 1.5 227 10 231 305 4.2 0 4.4 3.9 06/04/2005 12:00:00 1.7 0.5 2.6 0.4 2 0.3 2.6 1.1 214 13 228 305 3.9 0.1 4.2 3.7 06/04/2005 12:10:00 1.5 0.5 3 0.4 1.9 0.3 2.6 1.1 213 12 230 305 3.7 0 3.9 3.7 06/04/2005 12:20:00 1.2 0.4 2.3 0.4 1.7 0.4 2.6 0.7 215 11 204 305 3.8 0 3.9 3.7 06/04/2005 12:30:00 1.1 0.6 2.3 0.4 1.6 0.4 2.6 0.7 223 13 206 305 3.9 0 4.4 3.7 06/04/2005 12:40:00 1.8 0.5 3 0.4 2 0.5 3 0.4 221 14 230 305 4.3 0 4.7 4.2 06/04/2005 12:50:00 1.6 0.5 3 0.4 1.9 0.4 3 1.1 224 15 221 305 4.5 0.1 4.9 4.4 06/04/2005 13:00:00 2 0.5 3 0.4 2.3 0.4 3.4 1.1 216 9 208 305 4.5 0.1 4.9 4.4 06/04/2005 13:10:00 2.3 0.5 3.8 1.1 2.3 0.4 3.8 1.5 235 17 245 305 4.7 0.1 5.4 4.4 06/04/2005 13:20:00 2.7 0.5 3.8 1.1 2.4 0.5 3.4 1.1 267 12 261 305 5 0.2 5.9 4.9 06/04/2005 13:30:00 3 0.5 4.2 1.9 2.7 0.5 3.8 1.5 274 12 284 305 5.2 0.2 5.9 4.9 06/04/2005 13:40:00 2.3 1 4.2 0.4 2.4 0.7 4.2 0.4 234 45 294 305 4.9 0.1 5.6 4.7 06/04/2005 13:50:00 1.8 0.8 4.2 0.4 2 0.7 3.8 0.4 291 61 284 305 5.6 0.2 5.9 4.9 06/04/2005 14:00:00 2.7 0.6 4.2 0.4 2.9 0.5 4.2 1.1 323 15 328 305 5.7 0.1 5.9 5.4 06/04/2005 14:10:00 2.4 0.6 4.2 0.4 2.3 0.5 3.8 1.1 281 20 256 305 6 0.1 6.7 5.6 06/04/2005 14:20:00 1.3 0.6 3 0.4 1.6 0.6 3.4 0.4 245 90 129 305 6.2 0.3 6.9 5.9 06/04/2005 14:30:00 2.2 0.5 3.8 1.1 2.6 0.5 3.8 1.1 184 15 205 305 6.5 0.4 7.2 5.9 06/04/2005 14:40:00 2.8 0.6 4.6 0.7 2.8 0.5 4.2 1.9 238 27 221 305 5.7 0.2 6.1 5.4 06/04/2005 14:50:00 2.8 0.8 4.6 1.1 2.7 0.7 4.6 1.1 221 27 205 305 5.6 0.2 6.1 5.4 06/04/2005 15:00:00 2.5 0.5 3.8 1.1 2.4 0.5 3.8 1.1 242 27 247 305 6.1 0 6.4 5.9 06/04/2005 15:10:00 2.5 0.5 4.2 1.5 2.4 0.5 3.4 1.1 268 17 243 305 6 0 6.4 5.9 06/04/2005 15:20:00 2.5 0.7 4.2 0.7 2.4 0.7 4.2 0.7 286 17 301 305 6.1 0.1 6.4 5.9 06/04/2005 15:30:00 3.2 0.5 4.6 1.9 3 0.5 4.6 1.5 280 11 259 305 6 0 6.1 5.9 06/04/2005 15:40:00 2.8 0.6 4.6 1.1 2.6 0.5 4.2 1.1 269 11 285 305 5.9 0 6.1 5.9 06/04/2005 15:50:00 2.9 0.6 4.2 0.7 2.9 0.6 4.6 1.1 226 15 238 305 5.3 0.4 5.9 4.9 06/04/2005 16:00:00 2.5 0.6 4.6 0.7 2.4 0.6 4.2 0.7 226 18 232 305 5.2 0.1 5.4 4.9 06/04/2005 16:10:00 2.6 0.6 4.2 1.1 2.6 0.6 3.8 0.7 208 12 232 305 4.8 0 4.9 4.7 06/04/2005 16:20:00 2.4 0.5 3.4 0.7 2.4 0.5 3.4 1.1 212 11 200 305 4.7 0 4.9 4.4 06/04/2005 16:30:00 2 0.6 3.4 0.4 2.2 0.4 3.4 0.7 214 12 224 305 4.4 0 4.7 4.4 06/04/2005 16:40:00 2.5 0.5 3.8 0.7 2.6 0.5 3.8 1.5 208 10 208 305 4.7 0 4.9 4.4 06/04/2005 16:50:00 2.5 0.4 3.4 1.1 2.6 0.4 3.4 1.5 214 10 223 305 4.8 0 4.9 4.7 06/04/2005 17:00:00 2.8 0.5 4.2 1.5 2.9 0.5 4.2 1.5 217 9 212 305 4.6 0.2 4.9 4.2 06/04/2005 17:10:00 3.9 0.5 5.3 2.3 3.9 0.5 4.9 2.6 209 8 204 305 4.3 0 4.4 4.2 06/04/2005 17:20:00 4.2 0.4 4.9 3 4.2 0.4 4.9 3 206 5 205 305 4.2 0 4.4 4.2 06/04/2005 17:30:00 3.8 0.4 4.6 2.3 3.7 0.4 4.6 2.6 210 6 215 305 4.2 0.1 4.7 3.9 06/04/2005 17:40:00 3.8 0.4 4.6 2.6 3.8 0.4 4.9 2.6 212 6 213 305 4 0 4.4 3.9 06/04/2005 17:50:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 208 7 215 305 3.7 0 3.9 3.4 06/04/2005 18:00:00 3.1 0.4 3.8 1.9 3.2 0.4 4.2 2.3 206 6 214 305 3.7 0 3.7 3.4 06/04/2005 18:10:00 2.5 0.3 3.4 1.5 2.6 0.4 3.8 1.9 203 9 212 305 3.5 0 3.7 3.4 06/04/2005 18:20:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 208 8 212 305 3.7 0 3.7 3.4 06/04/2005 18:30:00 2.1 0.4 3 0.7 2.1 0.4 3 1.1 211 9 217 305 3.9 0 4.2 3.7 06/04/2005 18:40:00 2.1 0.4 3.4 1.1 2.2 0.4 3.4 1.1 208 11 200 305 4.2 0 4.4 4.2 06/04/2005 18:50:00 1.9 0.5 2.6 0.4 2 0.4 3 0.7 212 13 218 305 4.2 0 4.4 3.9 06/04/2005 19:00:00 1.6 0.5 2.6 0.4 1.8 0.4 2.6 1.1 216 15 200 305 4.3 0 4.4 4.2 06/04/2005 19:10:00 1.3 0.5 2.6 0.4 1.7 0.4 2.6 0.4 202 12 220 305 4 0.1 4.4 3.9 06/04/2005 19:20:00 2.3 0.4 3.4 1.1 2.3 0.4 3.4 1.1 206 13 213 305 3.7 0 3.9 3.7 06/04/2005 19:30:00 2.5 0.4 3.4 1.5 2.7 0.4 3.8 1.9 203 10 205 305 3.7 0 3.9 3.7 06/04/2005 19:40:00 2.3 0.4 3.4 1.1 2.3 0.4 3.4 1.1 203 9 201 305 3.9 0.1 4.2 3.7 06/04/2005 19:50:00 2.5 0.6 3.8 0.7 2.6 0.6 3.8 1.1 206 10 208 305 3.8 0 4.2 3.7 06/04/2005 20:00:00 1.9 0.5 3.4 0.7 2.3 0.4 3.4 1.5 189 10 177 305 3.7 0 3.7 3.4 06/04/2005 20:10:00 2.5 0.4 3 1.5 2.6 0.4 3.4 1.5 199 9 208 305 3.6 0 3.7 3.4 06/04/2005 20:20:00 2.8 0.5 4.2 1.5 2.9 0.5 4.2 1.5 194 7 194 305 3.4 0.1 3.4 3.2 06/04/2005 20:30:00 2.5 0.5 3.8 1.5 2.7 0.5 3.8 1.5 195 7 194 305 3.3 0 3.4 3.2 06/04/2005 20:40:00 3.1 0.4 3.8 1.9 3.3 0.3 4.2 2.3 193 6 198 305 3.3 0 3.4 3.2 06/04/2005 20:50:00 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.9 193 6 210 305 3 0 3.2 2.7 06/04/2005 21:00:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.9 201 7 221 305 3 0 3.2 2.9 06/04/2005 21:10:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.5 208 6 219 305 2.8 0 2.9 2.7 06/04/2005 21:20:00 3.4 0.5 4.6 2.3 3.2 0.5 4.6 1.9 216 8 211 305 2.8 0 3.2 2.7 06/04/2005 21:30:00 3 0.5 4.2 1.9 2.9 0.5 4.2 1.5 216 8 217 305 2.7 0 2.9 2.7 06/04/2005 21:40:00 3.1 0.6 4.6 1.9 3 0.6 4.6 1.9 212 9 223 305 2.6 0 2.9 2.5 06/04/2005 21:50:00 3.2 0.4 4.2 1.9 3 0.4 4.2 1.9 210 9 193 305 2.6 0 2.7 2.5 06/04/2005 22:00:00 2.5 0.5 3.4 1.1 2.4 0.5 3.8 1.1 219 8 215 305 2.6 0 2.7 2.5 06/04/2005 22:10:00 2.5 0.3 3 1.9 2.6 0.3 3.4 1.9 203 6 203 305 2.6 0.1 2.9 2.5 06/04/2005 22:20:00 2.7 0.3 3.4 2.3 2.9 0.3 3.8 2.3 202 5 198 305 2.9 0 3.2 2.9 06/04/2005 22:30:00 2.8 0.3 3.4 2.3 3 0.3 3.4 2.3 201 6 198 305 2.9 0 3.4 2.9 06/04/2005 22:40:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 201 6 200 305 2.9 0.1 3.4 2.7 06/04/2005 22:50:00 3.1 0.3 4.2 2.3 3.3 0.3 3.8 2.6 199 5 203 305 2.7 0 3.2 2.7 06/04/2005 23:00:00 3.5 0.3 4.6 3 3.8 0.3 4.6 2.6 202 5 203 305 2.6 0 3.2 2.5 06/04/2005 23:10:00 3.7 0.3 4.6 3 3.8 0.3 4.6 2.6 199 5 203 305 2.4 0 2.5 2.2 06/04/2005 23:20:00 3.1 0.3 4.2 1.9 3.3 0.3 4.2 2.3 196 7 188 305 2.3 0 2.5 2.2 06/04/2005 23:30:00 2.4 0.6 3.8 1.1 2.6 0.5 3.8 1.5 196 9 196 305 2.3 0 2.5 2.2 06/04/2005 23:40:00 1.5 0.4 2.3 0.4 1.9 0.4 2.6 0.7 192 8 190 305 2.5 0 2.5 2.2 06/04/2005 23:50:00 1.4 0.5 2.6 0.4 1.8 0.3 2.6 1.1 196 7 195 305 2.4 0 2.9 2.2 06/05/2005 00:00:00 1.9 0.3 2.6 0.7 2.1 0.4 3 1.1 201 5 196 305 2.3 0 2.9 2.2 06/05/2005 00:10:00 1.9 0.3 2.6 1.1 2 0.3 3 1.1 208 6 219 305 2.2 0 2.5 2 06/05/2005 00:20:00 2.2 0.3 3 1.5 2.3 0.2 3 1.9 204 6 195 305 2.1 0 2.2 2 06/05/2005 00:30:00 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.5 208 6 210 305 2 0 2.2 2 06/05/2005 00:40:00 2.7 0.4 3.4 1.5 2.6 0.4 3.4 1.5 214 11 231 305 1.9 0 2.2 1.7 06/05/2005 00:50:00 2.8 0.3 3.4 1.5 2.8 0.3 3.4 1.9 214 8 228 305 1.9 0 2.2 1.7 06/05/2005 01:00:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 208 5 216 305 1.9 0 2 1.7 06/05/2005 01:10:00 3 0.3 3.8 2.6 3 0.2 3.4 1.9 206 4 210 305 1.9 0 2.2 1.7 06/05/2005 01:20:00 3 0.3 3.8 2.3 3.1 0.2 3.8 2.3 203 5 211 305 1.9 0 2.2 1.7 06/05/2005 01:30:00 2.6 0.2 3 1.9 2.8 0.3 3.4 1.9 197 3 193 305 1.9 0 2.2 1.7 06/05/2005 01:40:00 3 0.3 3.8 2.3 3.2 0.2 3.8 2.6 197 4 198 305 1.9 0 2.2 1.7 06/05/2005 01:50:00 3.5 0.3 4.2 2.6 3.6 0.3 4.2 2.6 194 3 191 305 1.8 0.1 2.2 1.5 06/05/2005 02:00:00 3.4 0.3 4.2 2.3 3.5 0.4 4.2 2.3 192 5 193 305 1.7 0 2 1.5 06/05/2005 02:10:00 3.6 0.4 4.6 2.6 3.6 0.4 4.9 2.6 193 4 188 305 1.6 0 2 1.5 06/05/2005 02:20:00 3.4 0.4 4.6 2.3 3.6 0.4 4.6 2.6 192 5 194 305 1.6 0 2 1.5 06/05/2005 02:30:00 3.5 0.4 4.6 2.3 3.7 0.4 4.6 2.3 191 6 192 305 1.6 0 2.2 1.5 06/05/2005 02:40:00 3.4 0.4 4.6 2.3 3.6 0.4 4.6 2.6 193 5 199 305 1.7 0.1 2.2 1.5 06/05/2005 02:50:00 3.2 0.4 4.6 2.3 3.3 0.4 4.6 2.6 196 6 207 305 1.6 0 2 1.5 06/05/2005 03:00:00 3.2 0.4 4.2 2.3 3.3 0.3 4.2 2.3 192 4 198 305 1.6 0 2 1.5 06/05/2005 03:10:00 3.6 0.3 4.6 2.6 3.8 0.3 4.6 2.6 194 5 193 305 1.6 0 2 1.5 06/05/2005 03:20:00 3.8 0.4 4.6 3 3.9 0.4 4.9 3 196 5 199 305 1.4 0 2 1.3 06/05/2005 03:30:00 3.9 0.5 5.3 2.6 3.9 0.5 5.3 2.6 201 7 196 305 1.4 0 1.5 1.3 06/05/2005 03:40:00 4.2 0.4 5.3 3 4.1 0.4 5.3 2.6 199 5 198 305 1.4 0 1.5 1.3 06/05/2005 03:50:00 4.2 0.5 5.3 3 4.3 0.5 5.3 2.6 203 5 206 305 1.5 0 1.7 1.3 06/05/2005 04:00:00 4.7 0.5 6.1 3.4 4.4 0.5 5.7 2.6 221 8 227 305 1.5 0 2 1.3 06/05/2005 04:10:00 4.1 0.5 5.3 1.9 3.9 0.5 5.3 2.3 212 7 217 305 1.6 0 2.2 1.3 06/05/2005 04:20:00 4.2 0.5 5.3 2.6 4.1 0.6 5.3 2.6 202 6 200 305 1.4 0 2 1.3 06/05/2005 04:30:00 5 0.6 6.5 3.4 4.9 0.7 6.5 3.4 201 7 204 305 1.3 0 2 1.3 06/05/2005 04:40:00 3.9 0.5 4.9 2.6 3.8 0.5 4.9 2.3 218 10 231 305 1.4 0 2 1.3 06/05/2005 04:50:00 4.3 0.5 5.3 3 4.2 0.5 5.3 3 199 7 190 305 1.3 0.1 1.7 1 06/05/2005 05:00:00 3.4 0.6 5.3 1.9 3.4 0.7 4.9 2.3 216 11 204 305 1.2 0.1 1.7 1 06/05/2005 05:10:00 4.8 0.8 6.5 3 4.8 0.8 6.1 3.4 200 4 202 305 1.2 0.1 1.5 1 06/05/2005 05:20:00 4.2 0.6 6.1 3 4.1 0.6 5.7 2.6 213 10 224 305 1.2 0.1 1.7 1 06/05/2005 05:30:00 4.3 0.6 5.7 2.6 4.3 0.6 6.1 2.6 199 5 197 305 1.2 0.1 1.7 1 06/05/2005 05:40:00 4.6 0.5 5.7 3.4 4.4 0.5 5.7 3 201 9 193 305 1.2 0.1 1.7 1 06/05/2005 05:50:00 4.1 0.8 6.1 2.6 4 0.8 5.7 2.3 203 7 201 305 1.2 0.1 1.5 1 06/05/2005 06:00:00 4.1 0.6 5.7 2.6 4.1 0.7 5.7 2.6 210 10 194 305 1.3 0.1 1.7 1 06/05/2005 06:10:00 4.6 0.5 6.1 3.4 4.6 0.6 6.5 3.4 194 4 191 305 1.2 0.1 1.5 1 06/05/2005 06:20:00 4.5 0.8 5.7 1.9 4.4 0.9 5.7 2.3 203 8 198 305 1.2 0.1 1.5 1 06/05/2005 06:30:00 4.7 0.7 6.1 3 4.6 0.7 6.1 3 209 10 194 305 1.3 0.1 1.7 1 06/05/2005 06:40:00 4.6 0.5 5.7 3.4 4.6 0.5 5.7 3.4 199 6 208 305 1.2 0.1 1.5 1 06/05/2005 06:50:00 4.3 0.6 5.7 3 4.3 0.5 5.7 3 196 6 192 305 1.2 0.1 1.5 1 06/05/2005 07:00:00 4.4 0.5 5.7 3 4.4 0.5 5.7 3 197 4 194 305 1.2 0.1 1.5 1 06/05/2005 07:10:00 4.3 0.7 5.7 2.6 4.2 0.7 5.7 2.6 206 6 206 305 1.2 0.1 1.5 1 06/05/2005 07:20:00 4.3 0.4 5.3 3.4 4.2 0.5 5.7 3 195 5 203 305 1.1 0 1.5 1 06/05/2005 07:30:00 3.9 0.4 4.9 3 3.8 0.5 4.9 2.6 194 4 200 305 1.2 0 1.5 1 06/05/2005 07:40:00 3.8 0.5 5.3 1.9 3.8 0.5 5.3 1.9 198 8 197 305 1.2 0.1 1.5 1 06/05/2005 07:50:00 4.1 0.6 5.3 2.6 4.1 0.6 5.3 3 196 7 196 305 1.2 0.1 1.5 1 06/05/2005 08:00:00 4 0.7 5.7 2.3 4.1 0.7 5.7 2.6 193 8 191 305 1.1 0 1.5 1 06/05/2005 08:10:00 3.5 0.5 4.9 2.3 3.8 0.5 4.9 2.6 194 8 190 305 1.3 0.1 1.5 1 06/05/2005 08:20:00 3.1 0.6 4.2 1.5 3.3 0.6 4.6 1.5 192 9 191 305 1.3 0.1 1.7 1 06/05/2005 08:30:00 3.5 0.5 4.6 2.3 3.4 0.5 4.6 1.9 208 9 213 305 1.4 0 1.7 1.3 06/05/2005 08:40:00 3.9 0.5 4.9 2.6 3.9 0.5 5.3 2.6 204 7 216 305 1.4 0 1.7 1.3 06/05/2005 08:50:00 3.4 0.5 4.9 2.3 3.4 0.6 5.3 1.9 207 14 203 305 1.4 0 1.7 1.3 06/05/2005 09:00:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 2.3 210 7 204 305 1.5 0 2 1.3 06/05/2005 09:10:00 3.1 0.4 4.2 1.9 3.1 0.4 4.2 1.9 216 8 208 305 1.6 0 2 1.5 06/05/2005 09:20:00 3.7 0.4 4.6 2.6 3.6 0.5 4.9 2.3 214 5 218 305 1.6 0 2.2 1.5 06/05/2005 09:30:00 3 0.5 4.2 1.1 3 0.5 4.2 1.9 220 7 221 305 1.7 0.1 2.2 1.5 06/05/2005 09:40:00 3.3 0.4 4.2 1.9 3.3 0.5 4.6 2.3 219 6 231 305 1.9 0.2 2.5 1.5 06/05/2005 09:50:00 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.3 224 5 237 305 1.9 0.1 2.5 1.7 06/05/2005 10:00:00 3.5 0.5 4.6 2.3 3.4 0.5 4.6 2.3 220 6 220 305 2.1 0.1 2.7 2 06/05/2005 10:10:00 3.7 0.5 4.9 1.9 3.6 0.5 4.6 1.9 223 7 217 305 2 0.1 2.7 1.7 06/05/2005 10:20:00 3.7 0.6 4.9 2.3 3.6 0.6 4.9 2.3 230 8 238 305 2 0.1 2.5 1.5 06/05/2005 10:30:00 3.7 0.4 4.6 2.3 3.6 0.5 4.6 1.9 233 7 230 305 2 0.2 2.7 1.5 06/05/2005 10:40:00 3.8 0.4 4.9 3 3.8 0.4 5.3 2.6 234 6 227 305 2.3 0.2 2.7 2 06/05/2005 10:50:00 3.5 0.5 4.9 2.3 3.5 0.5 4.9 2.3 235 8 238 305 2.3 0.1 2.9 2 06/05/2005 11:00:00 3.7 0.4 4.6 2.6 3.7 0.4 4.6 2.6 239 7 243 305 2.2 0.1 2.7 2 06/05/2005 11:10:00 4.2 0.4 4.9 3 4.1 0.5 4.9 2.6 233 6 227 305 2.1 0 2.5 2 06/05/2005 11:20:00 4.2 0.4 4.9 2.6 4.1 0.4 4.9 3 237 6 227 305 2 0.1 2.5 2 06/05/2005 11:30:00 3.7 0.4 4.6 2.6 3.7 0.4 4.6 2.3 237 7 226 305 2 0 2.5 1.7 06/05/2005 11:40:00 3.5 0.5 4.9 2.3 3.6 0.4 4.6 2.3 243 9 237 305 2 0.1 2.5 1.7 06/05/2005 11:50:00 3.8 0.5 4.9 2.3 3.8 0.5 4.9 2.3 245 8 246 305 2.1 0 2.7 2 06/05/2005 12:00:00 4 0.5 4.9 2.6 3.9 0.5 4.9 2.3 245 8 255 305 2.2 0.1 2.7 2 06/05/2005 12:10:00 3.6 0.5 4.9 2.3 3.6 0.5 4.9 1.9 239 8 242 305 2.3 0.2 2.7 2 06/05/2005 12:20:00 3.5 0.4 4.2 1.9 3.5 0.4 4.6 2.3 241 8 235 305 2.3 0.1 2.7 2.2 06/05/2005 12:30:00 3.5 0.5 4.6 1.9 3.3 0.6 4.6 1.5 248 10 259 305 2.4 0.1 2.9 2.2 06/05/2005 12:40:00 3.3 0.5 4.6 2.3 3.3 0.5 4.6 2.3 240 10 255 305 2.5 0 2.9 2.2 06/05/2005 12:50:00 3.1 0.4 4.6 1.9 3.1 0.5 4.2 1.9 241 11 221 305 2.4 0.2 2.9 2.2 06/05/2005 13:00:00 3.4 0.4 4.6 2.3 3.4 0.4 4.2 2.3 233 9 242 305 2.2 0.1 2.5 2.2 06/05/2005 13:10:00 3.4 0.5 4.9 1.5 3.4 0.5 4.6 1.9 242 10 243 305 2.4 0 2.7 2.2 06/05/2005 13:20:00 3.5 0.4 4.6 2.6 3.4 0.5 4.6 2.3 234 10 224 305 2.5 0 2.7 2.2 06/05/2005 13:30:00 3.6 0.5 4.9 2.3 3.6 0.5 5.3 2.3 236 7 230 305 2.4 0 2.5 2.2 06/05/2005 13:40:00 3.7 0.5 5.7 2.6 3.7 0.4 4.9 2.6 237 6 239 305 2.3 0 2.5 2.2 06/05/2005 13:50:00 3.6 0.5 4.6 2.6 3.6 0.5 4.9 2.3 242 10 239 305 2.3 0 2.7 2.2 06/05/2005 14:00:00 3.6 0.4 4.6 2.6 3.4 0.5 4.6 1.9 246 10 259 305 2.5 0 2.7 2.2 06/05/2005 14:10:00 3.4 0.5 4.9 2.3 3.4 0.5 4.9 1.9 244 9 231 305 2.3 0.1 2.7 2.2 06/05/2005 14:20:00 3.1 0.4 4.6 1.9 3 0.5 4.2 1.9 248 9 247 305 2.4 0.1 2.9 2.2 06/05/2005 14:30:00 2.9 0.4 3.8 1.9 2.8 0.5 4.2 1.5 246 15 237 305 2.4 0 2.7 2.2 06/05/2005 14:40:00 2.7 0.6 4.2 1.1 2.5 0.5 3.8 1.5 255 13 239 305 2.5 0 2.7 2.5 06/05/2005 14:50:00 2.6 0.5 3.8 1.1 2.6 0.5 3.8 1.5 242 13 254 305 2.6 0 2.7 2.2 06/05/2005 15:00:00 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.5 231 12 231 305 2.6 0 2.9 2.5 06/05/2005 15:10:00 2.3 0.5 3.8 1.1 2.2 0.4 3 1.1 250 13 273 305 2.4 0 2.7 2.2 06/05/2005 15:20:00 1.8 0.5 3 0.4 1.9 0.5 3 1.1 237 17 239 305 2.3 0 2.7 2.2 06/05/2005 15:30:00 1.8 0.6 3 0.4 1.9 0.6 3 0.4 238 16 228 305 2.6 0 2.9 2.5 06/05/2005 15:40:00 2.1 0.5 3.4 0.7 2.1 0.4 3.4 1.1 251 19 241 305 2.4 0 2.7 2.2 06/05/2005 15:50:00 2.2 0.5 3.4 1.1 2 0.4 3.8 1.1 264 12 259 305 2.5 0 2.7 2.2 06/05/2005 16:00:00 2.5 0.5 3.8 1.5 2.5 0.4 3.4 1.5 250 9 254 305 2.3 0.1 2.7 2.2 06/05/2005 16:10:00 2.1 0.4 3 1.1 2 0.4 3.4 0.7 260 13 259 305 2.4 0 2.7 2.2 06/05/2005 16:20:00 2.4 0.5 3.4 1.1 2.2 0.5 3.4 0.7 270 12 275 305 2.6 0 2.9 2.5 06/05/2005 16:30:00 2.5 0.5 3.8 1.5 2.1 0.6 3.8 1.1 266 9 257 305 2.6 0 2.9 2.5 06/05/2005 16:40:00 2.1 0.5 3 0.7 1.9 0.5 3 0.7 272 14 294 305 2.7 0 3.2 2.5 06/05/2005 16:50:00 2 0.5 3.4 0.4 1.9 0.5 3 0.7 275 15 281 305 2.9 0 3.2 2.7 06/05/2005 17:00:00 2.5 0.5 3.8 0.7 2.5 0.5 3.8 1.5 289 12 294 305 2.8 0.1 3.2 2.7 06/05/2005 17:10:00 2.7 0.5 3.8 1.5 2.6 0.5 3.8 1.1 281 13 280 305 2.6 0.1 2.9 2.2 06/05/2005 17:20:00 2.2 0.6 3.8 0.7 2.2 0.5 3.4 1.1 277 13 268 305 2.4 0 2.7 2.2 06/05/2005 17:30:00 2.3 0.4 3 0.7 2.3 0.5 3.4 0.7 282 9 285 305 2.6 0 2.9 2.5 06/05/2005 17:40:00 2.2 0.4 3.4 1.1 2.2 0.4 3.4 1.1 284 12 291 305 2.6 0 2.9 2.5 06/05/2005 17:50:00 2.1 0.5 3 0.7 2.1 0.4 3.4 1.1 265 16 281 305 2.5 0.1 2.9 2.2 06/05/2005 18:00:00 1.4 0.5 2.6 0.4 1.5 0.4 2.6 0.4 263 17 287 305 2.5 0 2.9 2.2 06/05/2005 18:10:00 1.3 0.7 2.6 0.4 1.4 0.5 2.6 0.4 273 18 270 305 2.7 0 2.9 2.5 06/05/2005 18:20:00 0.7 0.5 1.9 0.4 1.2 0.5 2.6 0.4 241 23 248 305 2.6 0 2.9 2.5 06/05/2005 18:30:00 1.8 0.5 3 0.7 2 0.6 3 0.7 299 30 327 305 2.7 0.1 3.2 2.5 06/05/2005 18:40:00 2.4 0.4 3.4 1.1 2.5 0.4 3.4 1.1 315 10 305 305 2.6 0 2.9 2.5 06/05/2005 18:50:00 2 0.4 3 0.4 2.2 0.4 3 0.7 300 16 317 305 2.6 0 2.9 2.5 06/05/2005 19:00:00 2.3 0.5 4.2 0.7 2.3 0.5 4.2 1.1 298 21 306 305 2.8 0.1 3.2 2.5 06/05/2005 19:10:00 2.5 0.3 3.4 1.5 2.7 0.3 3.4 1.9 326 7 329 305 2.5 0.1 3.2 2.2 06/05/2005 19:20:00 1.8 0.4 2.6 0.4 2.1 0.4 3 1.1 335 9 332 305 2.3 0.1 2.7 2.2 06/05/2005 19:30:00 1.6 0.5 3 0.4 1.8 0.5 3.4 0.4 291 58 203 305 2.5 0 2.9 2.2 06/05/2005 19:40:00 1.1 0.6 2.3 0.4 1.3 0.4 2.3 0.4 229 27 285 305 2.5 0 2.9 2.2 06/05/2005 19:50:00 1.8 0.9 3.8 0.4 2 0.9 3.4 0.4 239 9 231 305 2.4 0.1 2.9 2.2 06/05/2005 20:00:00 1.1 0.6 2.6 0.4 1.4 0.5 2.6 0.4 220 22 228 305 2.3 0.1 2.7 2.2 06/05/2005 20:10:00 0.7 0.5 2.6 0.4 1.1 0.5 2.6 0.4 225 15 233 305 2.3 0.1 2.7 2.2 06/05/2005 20:20:00 0.8 0.6 2.3 0.4 1.1 0.6 2.3 0.4 279 82 238 305 2.3 0.1 2.7 2.2 06/05/2005 20:30:00 0.8 0.7 3 0.4 1.1 0.6 3.4 0.4 263 36 242 305 2.3 0.1 2.7 2.2 06/05/2005 20:40:00 1.9 0.7 3.8 0.4 2 0.7 3.8 0.4 301 28 305 305 2.3 0.1 2.7 2.2 06/05/2005 20:50:00 2.1 0.5 3.4 0.4 2.3 0.4 3.8 1.1 305 12 293 305 2.2 0.1 2.7 2 06/05/2005 21:00:00 2 0.5 3 1.1 2.3 0.5 3.4 1.1 305 10 311 305 2.2 0 2.5 2 06/05/2005 21:10:00 1.9 0.8 3.4 0.4 2 0.7 3.8 0.4 290 12 274 305 2.2 0.1 2.5 2 06/05/2005 21:20:00 2.1 0.7 4.2 0.4 2.2 0.7 4.2 0.7 300 19 324 305 2.2 0.1 2.5 2 06/05/2005 21:30:00 1.6 0.5 3 0.4 1.9 0.5 3 0.7 312 12 303 305 2 0.1 2.5 2 06/05/2005 21:40:00 2 0.4 3 1.1 2.3 0.4 3.4 1.5 330 11 328 305 1.9 0.1 2.5 1.5 06/05/2005 21:50:00 1.4 0.4 2.3 0.4 1.9 0.4 2.6 0.7 340 6 334 305 1.7 0.1 2.2 1.5 06/05/2005 22:00:00 1.9 0.5 3 0.4 2.2 0.5 3 0.7 313 6 307 305 1.7 0.1 2.2 1.5 06/05/2005 22:10:00 0.8 0.4 2.3 0.4 1.3 0.4 2.3 0.4 327 17 318 305 1.6 0 2 1.5 06/05/2005 22:20:00 1.3 0.6 2.6 0.4 1.7 0.4 2.6 0.4 342 22 303 305 1.6 0 2 1.5 06/05/2005 22:30:00 1.4 0.5 2.6 0.4 1.7 0.5 2.6 0.4 328 12 303 305 1.5 0 2 1.3 06/05/2005 22:40:00 1.6 0.6 2.6 0.4 1.8 0.6 3 0.4 334 9 333 305 1.5 0 2 1.3 06/05/2005 22:50:00 1.4 0.4 1.9 0.4 1.7 0.4 2.6 0.4 7 13 359 305 1.4 0 1.7 1.3 06/05/2005 23:00:00 1.4 0.8 2.6 0.4 1.8 0.7 3 0.4 340 15 336 305 1.3 0.1 1.7 1.3 06/05/2005 23:10:00 0.9 0.6 2.3 0.4 1.3 0.6 2.6 0.4 334 17 319 305 1.3 0.1 1.5 1 06/05/2005 23:20:00 0.6 0.4 1.9 0.4 0.8 0.5 1.9 0.4 351 22 14 305 1.2 0.1 1.5 1 06/05/2005 23:30:00 1.6 0.5 2.6 0.4 2 0.5 3 0.4 9 15 355 305 1.2 0.1 1.5 1 06/05/2005 23:40:00 1.2 0.6 2.3 0.4 1.8 0.5 2.6 0.7 2 6 0 305 1 0.1 1.5 0.8 06/05/2005 23:50:00 1.6 0.5 2.3 0.4 2.1 0.4 3 1.1 344 13 347 305 0.9 0.1 1.3 0.8 06/06/2005 00:00:00 2.1 0.5 3 0.7 2.4 0.4 3 1.1 346 5 350 305 0.7 0.2 1.3 0.3 06/06/2005 00:10:00 1.2 0.6 2.6 0.4 1.7 0.5 2.6 0.4 10 10 9 305 0.7 0.2 1.3 0.6 06/06/2005 00:20:00 1.5 0.7 3 0.4 1.9 0.5 3.4 1.1 15 9 40 305 0.7 0.2 1.3 0.6 06/06/2005 00:30:00 2.3 0.4 3 1.1 2.5 0.4 3.4 1.5 16 12 24 305 0.7 0.1 1.3 0.6 06/06/2005 00:40:00 2.9 0.6 4.6 1.5 3.2 0.6 4.6 1.9 0 5 4 305 0.7 0.2 1.3 0.6 06/06/2005 00:50:00 2.5 0.4 3.8 1.5 2.7 0.4 3.8 1.9 7 10 7 305 0.6 0.2 1 0.3 06/06/2005 01:00:00 2 0.4 3 1.1 2.3 0.3 3 1.5 13 10 5 305 0.6 0.1 1 0.3 06/06/2005 01:10:00 1.7 0.4 2.6 0.7 2 0.3 2.6 1.1 14 7 11 305 0.5 0 1 0.3 06/06/2005 01:20:00 2.7 0.4 3.4 1.9 2.9 0.4 3.8 1.9 20 7 19 305 0.5 0 1 0.3 06/06/2005 01:30:00 3.1 0.5 4.2 1.9 3.3 0.5 4.6 2.3 18 6 19 305 0.4 0 1 0.3 06/06/2005 01:40:00 3.4 0.4 4.2 2.6 3.5 0.4 4.6 2.6 17 6 15 305 0.4 0 0.8 0.3 06/06/2005 01:50:00 3.7 0.4 4.9 2.6 3.8 0.4 4.9 3 17 5 18 305 0.3 0 0.8 0.1 06/06/2005 02:00:00 4.3 0.3 5.3 3.4 4.5 0.4 5.3 3.4 19 6 19 305 0.2 0 0.6 0.1 06/06/2005 02:10:00 3.3 0.5 4.6 1.9 3.5 0.5 4.6 2.3 27 8 24 305 0.2 0 0.6 0.1 06/06/2005 02:20:00 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.3 35 9 24 305 0.1 0.1 0.6 0.1 06/06/2005 02:30:00 3.6 0.5 4.6 2.3 3.7 0.5 4.9 2.6 29 7 21 305 0.1 0.1 0.6 0.1 06/06/2005 02:40:00 4.4 0.5 5.3 3 4.5 0.5 5.3 3 31 4 25 305 0.1 0 0.6 0.1 06/06/2005 02:50:00 5.4 0.5 6.5 4.2 5.6 0.5 6.5 4.2 34 4 35 305 0 0 0.6 0.1 06/06/2005 03:00:00 5.2 0.3 6.1 4.6 5.4 0.3 6.1 4.6 33 4 37 305 0 0 0.3 0.1 06/06/2005 03:10:00 5.3 0.3 6.1 4.2 5.4 0.4 6.5 4.6 36 5 45 305 0 0 0.3 -0.1 06/06/2005 03:20:00 5 0.4 6.1 3.8 5.1 0.5 6.1 3.8 38 5 40 305 0 0 0.3 -0.1 06/06/2005 03:30:00 4.8 0.4 5.7 3.8 5 0.4 5.7 3.8 42 5 37 305 0 0 0.3 -0.1 06/06/2005 03:40:00 4.2 0.5 5.3 3 4.3 0.5 5.3 2.6 44 6 52 305 0 0.1 0.6 -0.1 06/06/2005 03:50:00 5 0.5 6.1 3.8 5.1 0.5 6.5 4.2 49 6 48 305 0.1 0 0.6 0.1 06/06/2005 04:00:00 5.7 0.4 6.8 4.2 5.8 0.5 7.2 4.2 44 5 40 305 0.3 0 0.6 0.1 06/06/2005 04:10:00 5.9 0.5 7.2 4.6 6 0.5 7.2 4.6 41 6 39 305 0.3 0 0.6 0.1 06/06/2005 04:20:00 6.3 0.4 7.2 4.9 6.4 0.5 7.6 4.9 43 6 43 305 0.2 0.1 0.6 0.1 06/06/2005 04:30:00 5.9 0.4 6.8 4.6 6 0.5 6.8 4.2 42 7 46 305 0.1 0.1 0.6 0.1 06/06/2005 04:40:00 6.8 0.4 8 5.7 7 0.5 8 5.3 47 6 33 305 0 0 0.6 -0.1 06/06/2005 04:50:00 7.4 0.5 8.4 6.1 7.6 0.6 8.8 6.1 37 3 37 305 -0.1 0 0.3 -0.4 06/06/2005 05:00:00 7.7 0.4 8.8 6.5 7.9 0.5 9.1 6.1 43 3 46 305 -0.2 0 0.1 -0.4 06/06/2005 05:10:00 7.1 0.5 9.1 6.1 7.2 0.6 9.5 6.1 42 0 42 305 -0.3 0 0.3 -0.4 06/06/2005 05:20:00 7.2 0.5 8.4 5.3 7.4 0.6 8.8 5.3 43 0 42 305 -0.4 0.1 0.1 -0.6 06/06/2005 05:30:00 7.2 0.6 8.4 5.7 7.3 0.7 8.4 5.3 42 0 42 305 -0.5 0.1 0.1 -0.6 06/06/2005 05:40:00 6.2 0.5 7.2 4.9 6.4 0.5 7.6 4.9 42 0 42 305 -0.5 0.1 0.1 -0.6 06/06/2005 05:50:00 7 0.4 8 5.3 7.2 0.5 8.4 5.7 42 0 42 305 -0.5 0 0.1 -0.6 06/06/2005 06:00:00 8.2 0.5 9.1 6.8 8.3 0.5 9.5 6.8 42 0 42 305 -0.6 0 0.1 -0.6 06/06/2005 06:10:00 7.6 0.6 8.8 5.7 7.8 0.6 9.1 6.1 42 0 42 305 -0.7 0 -0.1 -0.8 06/06/2005 06:20:00 6.1 0.5 7.2 4.6 6.1 0.6 7.6 3.8 42 0 42 305 -0.5 0 0.1 -0.6 06/06/2005 06:30:00 6.8 0.6 8.4 5.3 6.9 0.7 8.8 4.9 42 0 42 305 -0.5 0.1 0.1 -0.6 06/06/2005 06:40:00 8 0.6 9.1 6.8 8.2 0.6 9.1 6.5 42 0 42 305 -0.4 0.1 0.1 -0.6 06/06/2005 06:50:00 9.1 0.4 10.3 8 9.2 0.5 10.3 7.2 42 0 42 305 -0.3 0 0.3 -0.4 06/06/2005 07:00:00 9.7 0.4 10.7 8.4 10 0.5 11.1 8.8 42 0 42 305 -0.3 0 0.3 -0.4 06/06/2005 07:10:00 10.2 0.4 11.1 9.1 10.4 0.5 11.5 8.8 42 0 42 305 -0.4 0.1 0.3 -0.6 06/06/2005 07:20:00 9.9 0.6 11.1 8 10 0.7 11.5 7.6 42 0 42 305 -0.4 0.1 0.3 -0.6 06/06/2005 07:30:00 9.8 0.5 10.7 8.4 9.8 0.6 11.5 8 42 0 42 305 -0.3 0.1 0.3 -0.4 06/06/2005 07:40:00 8.9 0.6 10.3 6.8 9 0.8 10.3 6.5 42 0 42 305 -0.3 0.1 0.3 -0.4 06/06/2005 07:50:00 7.9 0.6 9.1 5.7 8 0.8 9.1 5.3 42 0 42 305 -0.1 0 0.6 -0.4 06/06/2005 08:00:00 8.2 0.5 9.1 6.1 8.3 0.6 9.5 6.1 42 0 42 305 -0.1 0 0.1 -0.4 06/06/2005 08:10:00 7.6 0.5 8.8 6.1 7.7 0.7 9.1 5.3 42 0 42 305 0 0 0.3 -0.1 06/06/2005 08:20:00 7.2 0.5 8.8 5.7 7.3 0.6 8.8 4.9 42 0 42 305 -0.1 0 0.6 -0.4 06/06/2005 08:30:00 7.4 0.5 8.8 6.1 7.6 0.5 8.8 6.1 42 0 42 305 0 0 0.6 -0.4 06/06/2005 08:40:00 8.1 0.6 9.5 6.5 8.3 0.8 9.9 6.1 42 0 42 305 0.1 0.1 0.6 0.1 06/06/2005 08:50:00 9.1 0.4 9.9 8 9.2 0.5 10.3 7.6 42 0 42 305 0.3 0 0.8 0.1 06/06/2005 09:00:00 9.4 0.4 10.3 8.4 9.5 0.5 10.7 8 43 1 42 305 0.4 0 1 0.3 06/06/2005 09:10:00 8.6 0.6 9.9 6.8 8.5 0.7 9.9 6.5 44 2 44 305 0.8 0.1 1.3 0.6 06/06/2005 09:20:00 8.6 0.4 9.5 7.6 8.6 0.6 9.5 6.8 43 2 44 305 1 0 1.5 0.8 06/06/2005 09:30:00 8.2 0.4 9.1 6.8 8.3 0.5 9.1 6.5 43 3 44 305 1.2 0.1 1.5 1 06/06/2005 09:40:00 8.3 0.5 9.5 6.5 8.3 0.7 9.5 6.1 45 3 45 305 1.4 0 2 1.3 06/06/2005 09:50:00 8.5 0.5 9.5 6.5 8.3 0.7 9.5 6.1 45 3 43 305 1.7 0.2 2.5 1.3 06/06/2005 10:00:00 9 0.6 10.3 7.2 8.9 0.8 10.3 6.8 47 3 50 305 1.9 0.2 2.5 1.5 06/06/2005 10:10:00 9.6 0.5 10.7 8.4 9.4 0.6 10.7 7.6 47 2 50 305 1.9 0.2 2.5 1.5 06/06/2005 10:20:00 9.9 0.4 10.7 8.4 9.7 0.6 11.1 7.2 46 3 48 305 1.7 0.2 2.2 1.5 06/06/2005 10:30:00 10 0.5 11.1 8.4 9.9 0.7 11.1 7.6 47 2 48 305 1.7 0.2 2.5 1.5 06/06/2005 10:40:00 9.7 0.4 10.7 8.4 9.5 0.6 10.7 7.6 46 3 44 305 1.8 0.2 2.5 1.5 06/06/2005 10:50:00 9.6 0.5 10.7 8.4 9.4 0.6 10.7 7.2 46 2 45 305 1.7 0.2 2.2 1.5 06/06/2005 11:00:00 9.2 0.5 10.3 7.6 9 0.7 10.3 6.8 43 3 41 305 2 0.2 2.5 1.5 06/06/2005 11:10:00 8.9 0.5 9.9 7.2 8.6 0.6 9.9 6.5 42 2 45 305 1.9 0.1 2.5 1.5 06/06/2005 11:20:00 8.6 0.4 9.1 6.8 8.4 0.5 9.5 6.8 40 2 40 305 1.7 0.1 2.2 1.5 06/06/2005 11:30:00 8.3 0.4 9.1 6.8 8.1 0.6 9.1 6.1 43 3 40 305 1.8 0.2 2.5 1.5 06/06/2005 11:40:00 9.5 0.6 10.7 8 9.4 0.7 10.7 6.8 41 2 41 305 1.8 0.1 2.2 1.5 06/06/2005 11:50:00 9.6 0.4 10.7 8.8 9.5 0.5 10.7 8.4 40 2 40 305 1.9 0.1 2.5 1.5 06/06/2005 12:00:00 9.9 0.5 11.5 8 9.8 0.6 11.5 7.2 42 3 42 305 1.7 0.1 2.2 1.3 06/06/2005 12:10:00 10.3 0.4 11.5 9.1 10.2 0.5 11.1 8.4 44 2 43 305 1.6 0.1 2.2 1.3 06/06/2005 12:20:00 10.4 0.3 11.1 9.5 10.4 0.5 11.1 9.1 42 2 45 305 1.7 0.1 2.2 1.3 06/06/2005 12:30:00 10.3 0.5 11.5 8 10.1 0.7 11.5 8 42 2 40 305 1.6 0.1 2.2 1.3 06/06/2005 12:40:00 10.1 0.6 11.1 8.4 10.1 0.6 11.5 8 42 2 42 305 1.4 0.1 2 1.3 06/06/2005 12:50:00 9.8 0.5 11.1 8.4 9.7 0.7 11.5 7.6 41 3 41 305 1.5 0.1 2.2 1.3 06/06/2005 13:00:00 10.3 0.4 11.1 9.1 10.3 0.4 11.1 8.8 39 2 39 305 1.3 0.2 1.7 1 06/06/2005 13:10:00 9.7 0.4 10.7 8.4 9.7 0.5 10.7 8 40 3 41 305 1.3 0.1 2 1 06/06/2005 13:20:00 9.5 0.4 10.3 8 9.5 0.4 10.3 8 38 3 39 305 1.3 0.2 2 1 06/06/2005 13:30:00 9.9 0.5 11.1 8.8 9.9 0.5 11.1 8 37 2 41 305 1.2 0.2 1.5 1 06/06/2005 13:40:00 10.5 0.3 11.1 9.5 10.5 0.4 11.5 9.1 38 2 36 305 1.1 0.2 1.5 0.8 06/06/2005 13:50:00 10.6 0.3 11.5 9.5 10.7 0.4 11.5 9.1 42 2 41 305 1.1 0.2 1.5 0.8 06/06/2005 14:00:00 10.6 0.4 11.5 9.1 10.6 0.4 11.5 8.8 43 2 43 305 1.1 0.1 1.5 1 06/06/2005 14:10:00 10.6 0.3 11.5 9.5 10.6 0.4 11.5 9.1 42 2 44 305 1.2 0.2 1.7 0.8 06/06/2005 14:20:00 10.6 0.5 11.5 8.8 10.6 0.6 11.8 8 46 3 44 305 1.4 0.2 2.2 1 06/06/2005 14:30:00 10.6 0.4 11.8 8.8 10.6 0.6 11.8 8.4 42 3 41 305 1.2 0.2 1.7 0.8 06/06/2005 14:40:00 10.4 0.4 11.5 9.1 10.5 0.5 11.5 8.8 40 3 40 305 0.9 0.2 1.5 0.6 06/06/2005 14:50:00 10.4 0.4 11.5 9.1 10.4 0.5 11.5 8.8 40 4 44 305 0.9 0.2 1.5 0.6 06/06/2005 15:00:00 10.6 0.4 11.5 9.5 10.5 0.6 11.5 8.8 42 4 42 305 0.7 0.2 1.3 0.6 06/06/2005 15:10:00 10.2 0.5 11.5 8.4 10.2 0.6 11.8 8 42 4 36 305 0.8 0.2 1.5 0.6 06/06/2005 15:20:00 10.6 0.4 11.5 8.8 10.6 0.5 11.5 8.8 42 3 42 305 0.6 0.1 1.3 0.3 06/06/2005 15:30:00 10.5 0.4 11.5 9.5 10.6 0.4 11.5 9.5 43 3 42 305 0.6 0.2 1.3 0.3 06/06/2005 15:40:00 10 0.5 11.1 8.4 10 0.6 11.1 8 41 3 42 305 0.6 0.1 1.3 0.3 06/06/2005 15:50:00 9.9 0.5 11.1 8 9.9 0.6 11.1 7.6 37 3 37 305 0.6 0.1 1 0.3 06/06/2005 16:00:00 9.8 0.3 10.7 8.8 9.8 0.4 10.7 8.8 36 2 33 305 0.6 0.1 1 0.3 06/06/2005 16:10:00 9.5 0.5 10.7 8 9.5 0.6 11.1 7.6 38 4 33 305 0.7 0.2 1.3 0.6 06/06/2005 16:20:00 9.4 0.4 10.3 8 9.4 0.5 10.3 8 38 3 37 305 0.6 0.1 1.3 0.3 06/06/2005 16:30:00 9 0.5 9.9 7.2 9 0.6 10.3 6.8 38 3 38 305 0.6 0.1 1.3 0.3 06/06/2005 16:40:00 9.2 0.5 10.3 7.6 9.1 0.6 10.3 7.2 39 4 36 305 0.9 0.2 1.5 0.6 06/06/2005 16:50:00 9.5 0.5 10.3 7.6 9.5 0.6 10.7 7.2 41 3 40 305 0.7 0.2 1.3 0.6 06/06/2005 17:00:00 9.5 0.5 10.7 7.6 9.5 0.5 10.7 7.6 42 3 41 305 1 0.1 1.5 0.6 06/06/2005 17:10:00 9.6 0.3 10.3 8.4 9.6 0.4 10.7 8.4 41 3 42 305 0.9 0.2 1.5 0.6 06/06/2005 17:20:00 9.3 0.4 10.3 8 9.3 0.5 10.3 7.6 39 5 46 305 1 0.2 1.5 0.6 06/06/2005 17:30:00 9.1 0.4 10.3 7.6 9.1 0.6 10.3 7.2 41 3 37 305 1.2 0.2 1.7 0.8 06/06/2005 17:40:00 9 0.4 9.9 7.6 8.9 0.5 9.9 7.2 40 4 37 305 1.2 0.2 1.7 0.8 06/06/2005 17:50:00 9.1 0.6 10.3 7.2 9 0.7 10.7 7.2 39 4 43 305 1 0.2 1.5 0.6 06/06/2005 18:00:00 9.3 0.5 10.3 8 9.3 0.6 10.7 7.6 41 4 40 305 0.9 0.2 1.5 0.6 06/06/2005 18:10:00 9 0.4 9.9 7.6 9 0.6 10.3 7.2 40 4 33 305 0.8 0.2 1.3 0.6 06/06/2005 18:20:00 9.1 0.4 9.9 8 9.1 0.5 9.9 7.6 36 4 32 305 0.7 0.2 1.3 0.3 06/06/2005 18:30:00 9.4 0.4 10.3 8.4 9.5 0.4 10.7 8 40 3 41 305 0.7 0.2 1.3 0.3 06/06/2005 18:40:00 9.3 0.5 10.3 7.6 9.4 0.5 10.3 7.6 39 4 37 305 0.6 0.1 1 0.3 06/06/2005 18:50:00 9.2 0.5 10.3 7.6 9.1 0.6 10.3 7.6 39 4 41 305 0.5 0.2 1 0.1 06/06/2005 19:00:00 9.7 0.4 10.7 7.6 9.7 0.6 10.7 7.6 42 3 37 305 0.6 0.1 1 0.3 06/06/2005 19:10:00 9.2 0.4 10.3 7.6 9.3 0.5 10.3 7.2 39 3 47 305 0.6 0.1 1.3 0.6 06/06/2005 19:20:00 9.4 0.4 10.3 8 9.5 0.5 10.7 7.6 41 2 41 305 0.7 0.2 1.3 0.6 06/06/2005 19:30:00 9.1 0.4 9.9 8 9.2 0.4 9.9 8 39 2 38 305 0.6 0.2 1.3 0.6 06/06/2005 19:40:00 8.4 0.5 9.5 6.8 8.4 0.6 9.5 6.5 36 3 36 305 0.7 0.2 1.3 0.6 06/06/2005 19:50:00 8.5 0.4 9.5 7.6 8.5 0.5 9.5 7.2 41 3 40 305 0.6 0.1 1.3 0.3 06/06/2005 20:00:00 8.4 0.3 9.1 7.6 8.5 0.4 9.5 7.6 41 3 41 305 0.6 0.2 1.3 0.6 06/06/2005 20:10:00 8.8 0.5 9.9 6.8 8.7 0.6 10.3 6.1 45 3 46 305 0.6 0.2 1.3 0.6 06/06/2005 20:20:00 8.8 0.5 9.5 7.6 8.8 0.5 9.5 7.2 42 3 52 305 0.6 0.1 1.3 0.6 06/06/2005 20:30:00 8.3 0.4 9.5 7.2 8.3 0.5 9.5 6.8 43 3 45 305 0.6 0.1 1 0.3 06/06/2005 20:40:00 8.5 0.4 9.5 7.2 8.5 0.5 9.1 6.8 40 3 38 305 0.6 0.2 1 0.6 06/06/2005 20:50:00 8.1 0.4 9.1 6.8 8.2 0.4 9.1 6.8 39 2 40 305 0.6 0.1 1 0.3 06/06/2005 21:00:00 8 0.5 9.1 6.8 8 0.5 9.1 6.8 39 3 36 305 0.5 0 1 0.3 06/06/2005 21:10:00 7.9 0.5 9.1 6.8 7.9 0.5 9.1 6.5 39 3 40 305 0.5 0 1 0.6 06/06/2005 21:20:00 7.2 0.4 8 6.1 7.2 0.4 8.4 6.1 41 3 41 305 0.6 0.1 1.3 0.6 06/06/2005 21:30:00 7.5 0.5 8.8 6.5 7.5 0.5 8.8 6.1 41 4 49 305 0.6 0.1 1.3 0.6 06/06/2005 21:40:00 7.5 0.4 8.8 6.5 7.5 0.5 8.8 6.1 41 3 36 305 0.7 0.1 1.3 0.6 06/06/2005 21:50:00 7.6 0.5 8.8 6.1 7.6 0.5 8.8 5.7 40 4 44 305 0.9 0 1.3 0.6 06/06/2005 22:00:00 7.7 0.6 9.1 6.1 7.6 0.7 9.5 5.7 43 4 41 305 0.9 0 1.5 0.8 06/06/2005 22:10:00 7.5 0.6 8.8 6.1 7.4 0.7 9.1 5.3 43 4 50 305 1.1 0.1 1.5 0.8 06/06/2005 22:20:00 7.3 0.4 8.4 6.1 7.3 0.5 8.4 6.1 41 3 45 305 0.8 0.2 1.5 0.6 06/06/2005 22:30:00 7 0.4 8 6.1 6.9 0.4 7.6 5.7 40 3 43 305 0.6 0.2 1 0.3 06/06/2005 22:40:00 7.1 0.4 8.4 6.1 7 0.4 8 5.7 43 4 47 305 0.6 0.1 1 0.6 06/06/2005 22:50:00 7 0.4 8 6.1 7 0.4 8 5.7 43 3 46 305 0.6 0.1 1 0.3 06/06/2005 23:00:00 7.2 0.4 8 6.5 7 0.4 8 6.1 45 3 54 305 0.5 0 1 0.3 06/06/2005 23:10:00 7 0.4 8.4 6.1 7 0.4 8 6.1 41 3 38 305 0.4 0 0.8 0.3 06/06/2005 23:20:00 7.2 0.4 8 6.1 7.2 0.4 8 5.7 46 3 45 305 0.3 0 0.6 0.1 06/06/2005 23:30:00 6.9 0.5 7.6 5.3 6.9 0.5 8 5.3 45 5 48 305 0.3 0 0.6 0.1 06/06/2005 23:40:00 7.3 0.5 8.4 6.1 7.3 0.4 8.4 6.5 41 3 41 305 0.1 0 0.3 0.1 06/06/2005 23:50:00 7.6 0.5 9.5 6.5 7.5 0.6 9.1 5.7 42 6 46 305 0 0 0.3 0.1 06/07/2005 00:00:00 7.8 0.6 9.1 6.5 7.7 0.6 9.1 6.5 38 4 42 305 0 0 0.6 0.1 06/07/2005 00:10:00 7.4 0.5 8.4 6.1 7.4 0.5 8.8 6.1 42 3 43 305 0 0 0.3 -0.1 06/07/2005 00:20:00 7.7 0.5 9.1 6.5 7.7 0.5 9.1 6.5 42 3 42 305 -0.1 0 0.3 -0.4 06/07/2005 00:30:00 8 0.5 9.5 6.8 8 0.5 9.5 6.5 43 4 42 305 -0.1 0 0.3 -0.4 06/07/2005 00:40:00 7.9 0.5 9.1 6.8 8 0.5 9.1 6.8 41 4 40 305 -0.2 0 0.3 -0.4 06/07/2005 00:50:00 8.1 0.5 9.1 6.8 8.2 0.5 9.5 6.8 44 4 44 305 -0.3 0.1 0.1 -0.4 06/07/2005 01:00:00 7.8 0.5 9.1 6.8 7.9 0.5 9.1 6.5 45 3 39 305 -0.5 0.1 0.1 -0.6 06/07/2005 01:10:00 7.9 0.4 8.8 6.8 7.8 0.5 8.8 6.8 40 4 42 305 -0.5 0.1 0.1 -0.6 06/07/2005 01:20:00 8.7 0.5 9.5 7.2 8.6 0.5 9.9 6.8 39 3 36 305 -0.5 0.1 0.1 -0.6 06/07/2005 01:30:00 8.3 0.5 9.5 6.8 8.4 0.5 9.5 6.8 39 3 35 305 -0.5 0.1 0.1 -0.6 06/07/2005 01:40:00 8.4 0.4 9.5 7.2 8.5 0.4 9.5 7.6 40 3 44 305 -0.5 0.1 0.1 -0.6 06/07/2005 01:50:00 7.9 0.6 9.1 6.5 8 0.6 9.1 6.5 31 3 31 305 -0.5 0.1 0.1 -0.6 06/07/2005 02:00:00 8.5 0.5 9.5 7.2 8.4 0.5 9.5 6.8 33 3 33 305 -0.6 0.1 0.1 -0.6 06/07/2005 02:10:00 9 0.5 10.7 7.6 9 0.5 10.3 7.2 32 6 37 305 -0.8 0.2 0.1 -1.1 06/07/2005 02:20:00 9 0.6 10.3 7.6 9 0.6 10.7 7.6 35 3 38 305 -0.8 0.1 -0.1 -1.1 06/07/2005 02:30:00 9.2 0.5 10.3 8 9.2 0.5 10.3 8 36 4 40 305 -0.9 0.1 -0.4 -1.1 06/07/2005 02:40:00 8.7 0.8 10.7 6.5 8.6 0.8 10.3 6.8 31 4 25 305 -0.9 0.1 -0.4 -1.1 06/07/2005 02:50:00 9.6 0.4 10.7 8.8 9.6 0.5 11.1 8.4 32 3 36 305 -1.1 0 -0.6 -1.1 06/07/2005 03:00:00 9.5 0.7 11.1 7.6 9.5 0.8 11.5 7.2 35 5 38 305 -1 0.1 -0.6 -1.1 06/07/2005 03:10:00 9.2 0.6 10.7 7.6 9.2 0.7 10.7 7.6 34 3 30 305 -1.1 0 -0.6 -1.3 06/07/2005 03:20:00 9.6 0.7 11.1 7.6 9.5 0.8 11.1 7.2 38 4 40 305 -1.1 0 -0.6 -1.3 06/07/2005 03:30:00 10 0.5 11.1 8.8 10 0.5 11.1 8.4 38 4 37 305 -1.1 0 -0.6 -1.3 06/07/2005 03:40:00 9.8 0.6 11.1 8.4 9.8 0.6 11.1 8.4 36 4 30 305 -1.2 0 -0.8 -1.5 06/07/2005 03:50:00 9.7 0.5 10.7 8.4 9.6 0.5 10.7 8.4 34 3 29 305 -1.2 0 -0.6 -1.3 06/07/2005 04:00:00 9.7 0.6 11.5 8.4 9.6 0.6 11.1 8 42 6 50 305 -1.2 0 -0.8 -1.3 06/07/2005 04:10:00 9.9 0.5 11.1 8.4 9.9 0.5 11.1 8.8 40 3 45 305 -1.3 0 -0.8 -1.3 06/07/2005 04:20:00 10.7 0.4 11.8 9.5 10.7 0.5 11.8 9.1 39 3 44 305 -1.3 0 -0.8 -1.5 06/07/2005 04:30:00 10.2 0.5 12.2 8.8 10.2 0.6 12.2 8.8 41 4 39 305 -1.4 0 -1.1 -1.5 06/07/2005 04:40:00 9.9 0.5 11.1 8 9.7 0.6 11.1 8 46 3 45 305 -1.3 0 -1.1 -1.5 06/07/2005 04:50:00 9.6 0.6 11.1 7.6 9.4 0.6 11.1 7.6 39 6 42 305 -1.3 0 -1.1 -1.5 06/07/2005 05:00:00 10 0.7 11.5 8 9.9 0.8 11.1 7.6 37 8 27 305 -1.4 0.1 -0.8 -1.5 06/07/2005 05:10:00 10.7 0.5 11.8 9.1 10.6 0.7 12.2 8.8 42 5 40 305 -1.5 0.1 -1.1 -1.8 06/07/2005 05:20:00 10.2 0.7 11.8 8.8 10.1 0.8 11.8 8 42 4 47 305 -1.4 0.1 -1.1 -1.5 06/07/2005 05:30:00 10.4 0.7 11.8 8.8 10.4 0.8 11.8 8 39 4 44 305 -1.5 0.1 -1.1 -1.8 06/07/2005 05:40:00 10.3 0.6 11.5 8.4 10.3 0.7 11.8 8 44 0 44 305 -1.5 0.1 -1.1 -1.8 06/07/2005 05:50:00 10 0.6 11.5 8.4 10 0.7 11.5 8 44 0 44 305 -1.4 0 -0.8 -1.5 06/07/2005 06:00:00 9.7 0.5 11.5 8.4 9.7 0.6 11.8 8 40 2 38 305 -1.4 0.1 -0.8 -1.5 06/07/2005 06:10:00 9.7 0.7 11.8 7.6 9.7 0.8 12.2 7.2 42 3 46 305 -1.5 0.1 -1.1 -1.8 06/07/2005 06:20:00 9.9 0.6 11.1 8 10 0.8 11.5 7.6 46 0 46 305 -1.5 0.1 -1.1 -1.8 06/07/2005 06:30:00 9.9 0.9 11.8 8 10 1 12.2 7.6 46 0 46 305 -1.6 0.1 -1.1 -1.8 06/07/2005 06:40:00 9.4 0.6 11.1 7.6 9.5 0.7 11.5 7.6 45 0 46 305 -1.5 0.1 -1.1 -1.8 06/07/2005 06:50:00 10 0.6 11.5 8.8 10.1 0.7 11.5 8.4 45 0 45 305 -1.6 0 -1.1 -2 06/07/2005 07:00:00 10 0.5 11.5 8.4 10 0.7 11.5 7.2 45 0 45 305 -1.7 0.1 -1.1 -2 06/07/2005 07:10:00 10 0.6 11.8 8.4 10 0.7 12.2 8 45 0 45 305 -1.6 0 -1.3 -1.8 06/07/2005 07:20:00 10.4 0.6 11.8 8.4 10.4 0.7 12.2 8.4 45 0 45 305 -1.7 0 -1.1 -1.8 06/07/2005 07:30:00 9.9 0.6 11.5 8 9.8 0.7 11.5 8 45 0 45 305 -1.6 0 -1.1 -1.8 06/07/2005 07:40:00 10.2 1 12.2 7.6 10.1 1 11.8 6.8 45 0 45 305 -1.5 0.1 -1.1 -1.8 06/07/2005 07:50:00 10.1 0.8 12.2 8.4 9.9 0.8 11.8 8 45 0 45 305 -1.5 0 -0.8 -1.8 06/07/2005 08:00:00 10.7 0.5 11.8 9.1 10.6 0.5 11.8 8.8 45 0 44 305 -1.4 0 -0.8 -1.5 06/07/2005 08:10:00 10.8 0.6 12.6 9.1 10.8 0.6 12.6 8.8 43 3 44 305 -1.4 0 -1.1 -1.5 06/07/2005 08:20:00 10.9 0.7 12.2 9.1 10.8 0.8 12.6 8.4 41 5 32 305 -1.2 0 -0.6 -1.3 06/07/2005 08:30:00 11 0.6 12.2 8.8 11 0.7 12.2 8.4 38 3 32 305 -1.4 0 -1.1 -1.5 06/07/2005 08:40:00 10.9 0.6 12.2 8.8 10.8 0.7 12.2 8.8 37 3 34 305 -1.2 0 -0.6 -1.3 06/07/2005 08:50:00 10.5 0.7 12.2 8.4 10.5 0.7 11.8 8.4 33 2 32 305 -1.1 0 -0.8 -1.3 06/07/2005 09:00:00 10.8 0.9 12.6 8.8 10.9 0.8 12.6 8.4 32 0 32 305 -1.2 0 -0.6 -1.3 06/07/2005 09:10:00 10.8 0.9 12.6 8.4 10.7 1 13 8 32 0 32 305 -1.2 0.1 -0.6 -1.5 06/07/2005 09:20:00 10.4 0.8 12.6 8 10.3 1 13 8 32 0 32 305 -1.1 0 -0.6 -1.3 06/07/2005 09:30:00 11.1 0.6 13 9.1 11.1 0.7 13 8.8 32 0 32 305 -1.2 0.1 -0.6 -1.5 06/07/2005 09:40:00 10.4 1 13 7.6 10.3 1.1 13 6.8 32 0 33 305 -1 0.1 -0.4 -1.1 06/07/2005 09:50:00 11.2 0.6 13 8.8 11.2 0.6 12.6 9.1 32 0 33 305 -1.1 0 -0.6 -1.3 06/07/2005 10:00:00 10.9 1 13 8.4 10.8 1.1 13.3 8 32 0 32 305 -1.1 0.1 -0.4 -1.3 06/07/2005 10:10:00 11.3 0.8 12.6 8.8 11.1 0.8 13 8.4 32 0 33 305 -1 0.1 -0.4 -1.3 06/07/2005 10:20:00 11 0.9 13.3 8.8 10.9 1.1 13 8.4 32 0 32 305 -0.9 0.1 -0.4 -1.1 06/07/2005 10:30:00 10.7 0.8 12.6 8.4 10.7 0.8 12.2 8.8 32 0 32 305 -0.8 0 -0.4 -1.1 06/07/2005 10:40:00 10.9 0.7 12.2 8.8 10.8 0.8 12.6 8 32 0 32 305 -0.8 0 -0.4 -1.1 06/07/2005 10:50:00 11.5 0.7 13 9.1 11.4 0.8 13 8.8 33 0 33 305 -0.8 0 -0.4 -1.1 06/07/2005 11:00:00 11 0.6 12.6 9.1 10.9 0.7 12.2 8.8 32 0 32 305 -0.7 0.1 -0.1 -1.1 06/07/2005 11:10:00 11.8 0.5 13 10.3 11.7 0.7 13.3 9.5 32 0 32 305 -0.7 0 -0.4 -0.8 06/07/2005 11:20:00 10.9 0.7 12.6 8.4 10.8 0.8 12.6 8.4 32 0 32 305 -0.5 0.1 0.1 -0.8 06/07/2005 11:30:00 11 0.5 12.6 9.1 10.8 0.6 12.6 8.8 32 0 32 305 -0.5 0.1 0.1 -0.6 06/07/2005 11:40:00 10.7 0.8 12.6 8.8 10.6 0.8 12.6 8.8 32 0 32 305 -0.4 0.1 0.1 -0.6 06/07/2005 11:50:00 11.3 0.8 12.6 9.1 11.2 0.8 13.3 9.1 32 0 32 305 -0.4 0.1 0.1 -0.6 06/07/2005 12:00:00 11.8 0.6 13.3 10.3 11.8 0.6 13.3 10.3 32 0 32 305 -0.5 0.1 0.1 -0.6 06/07/2005 12:10:00 11.3 0.8 13.3 9.5 11.3 0.8 13.3 8.8 32 0 32 305 -0.2 0 0.3 -0.4 06/07/2005 12:20:00 11.6 0.8 13.3 9.1 11.6 0.9 13.7 8.8 32 0 32 305 -0.3 0.1 0.3 -0.6 06/07/2005 12:30:00 11.6 0.7 13.3 9.5 11.5 0.8 13.3 9.1 32 0 33 305 -0.3 0.1 0.3 -0.6 06/07/2005 12:40:00 11.9 0.7 13.7 9.9 11.7 0.9 14.1 9.5 40 6 33 305 -0.1 0 0.6 -0.1 06/07/2005 12:50:00 11 0.6 12.2 9.1 10.7 0.6 12.2 8.8 45 0 45 305 0 0.1 0.6 -0.1 06/07/2005 13:00:00 11.3 0.7 13 9.5 10.9 0.8 12.6 8.8 45 0 45 305 0 0.1 0.6 -0.4 06/07/2005 13:10:00 11.9 0.5 13 10.3 11.4 0.6 12.6 9.5 45 0 45 305 0 0 0.6 -0.4 06/07/2005 13:20:00 11.7 0.7 13.3 10.3 11.1 0.7 12.6 9.1 45 0 45 305 0 0.1 0.6 -0.1 06/07/2005 13:30:00 11.2 0.7 12.6 9.1 10.6 0.8 12.2 8.4 45 0 45 305 0.1 0.1 0.6 0.1 06/07/2005 13:40:00 11.3 0.6 12.6 9.5 10.8 0.7 11.8 8.8 45 0 45 305 0 0.1 0.6 -0.1 06/07/2005 13:50:00 11.4 0.6 13 9.5 10.9 0.7 12.6 8 45 0 45 305 0.1 0.1 0.6 -0.1 06/07/2005 14:00:00 11.6 0.6 13 9.9 11.1 0.6 12.6 9.5 45 0 46 305 0 0.1 0.6 -0.1 06/07/2005 14:10:00 10.9 0.5 12.2 8.8 10.4 0.7 11.5 8 45 0 45 305 0.3 0.1 1 -0.1 06/07/2005 14:20:00 11.1 0.5 12.2 9.5 10.6 0.6 12.2 8.4 45 0 45 305 0.3 0.2 1 0.1 06/07/2005 14:30:00 10.8 0.6 12.2 9.1 10.3 0.6 11.8 8.4 45 0 45 305 0.2 0.1 0.6 0.1 06/07/2005 14:40:00 10.5 0.5 11.8 8.4 10.2 0.5 11.5 8.8 45 0 45 305 0.3 0 0.8 0.1 06/07/2005 14:50:00 11 0.5 12.6 9.1 10.5 0.7 11.8 8.8 45 0 45 305 0.2 0.1 0.8 -0.1 06/07/2005 15:00:00 11.1 0.6 12.2 8.8 10.7 0.7 11.8 8.4 45 0 45 305 0.2 0.1 0.8 0.1 06/07/2005 15:10:00 10.8 0.7 12.6 8 10.4 0.9 12.2 8 45 0 45 305 0.3 0.1 1 0.1 06/07/2005 15:20:00 11.4 0.5 12.6 9.9 11 0.5 12.2 8.8 45 0 45 305 0.2 0.1 0.6 0.1 06/07/2005 15:30:00 11.7 0.6 13.3 9.9 11.3 0.6 13 9.5 45 0 45 305 0.2 0.1 0.8 0.1 06/07/2005 15:40:00 11.4 0.5 12.6 9.9 11 0.6 12.2 9.1 45 0 45 305 0.3 0 0.8 0.1 06/07/2005 15:50:00 11.1 0.5 12.6 9.9 10.7 0.6 12.2 8.8 45 0 45 305 0.4 0 1 0.1 06/07/2005 16:00:00 11.2 0.5 12.6 9.9 10.9 0.5 12.6 9.5 45 0 45 305 0.3 0 0.8 0.1 06/07/2005 16:10:00 10.8 0.5 11.8 9.1 10.4 0.6 11.5 8 45 0 45 305 0.3 0.1 0.8 0.1 06/07/2005 16:20:00 10.4 0.5 11.5 8.8 10.1 0.6 11.5 8.4 45 0 45 305 0.2 0.1 0.6 0.1 06/07/2005 16:30:00 10.5 0.6 12.2 8.8 10.2 0.7 12.2 8.4 45 0 45 305 0.2 0.1 0.6 0.1 06/07/2005 16:40:00 10.7 0.7 12.2 8.4 10.2 0.8 11.8 7.6 45 0 45 305 0.2 0.1 0.6 0.1 06/07/2005 16:50:00 10.7 0.6 12.2 8.8 10.3 0.7 11.8 8 45 0 45 305 0.2 0.1 0.8 0.1 06/07/2005 17:00:00 10.3 0.7 12.2 8.4 9.9 0.7 11.8 7.6 45 0 45 305 0.4 0.1 1 0.1 06/07/2005 17:10:00 10.9 0.6 12.2 8.8 10.5 0.7 11.8 8.8 45 0 45 305 0.3 0.1 1 0.1 06/07/2005 17:20:00 10.8 0.6 12.2 8.8 10.4 0.7 11.8 8.4 45 0 45 305 0.2 0.2 0.8 0.1 06/07/2005 17:30:00 11.4 0.5 12.6 9.5 10.9 0.6 12.2 9.1 45 0 44 305 0.2 0.2 0.6 0.1 06/07/2005 17:40:00 10.6 0.7 11.8 7.6 10.1 0.8 11.5 7.6 45 0 45 305 0.4 0.1 1 0.1 06/07/2005 17:50:00 10.8 0.6 12.2 8.8 10.5 0.7 11.8 8.8 44 0 44 305 0.2 0.2 0.6 0.1 06/07/2005 18:00:00 10.7 0.6 12.2 9.1 10.3 0.6 11.8 8.8 44 0 44 305 0.2 0.2 0.8 0.1 06/07/2005 18:10:00 10.9 0.6 12.2 8.8 10.6 0.7 11.8 8.4 44 0 44 305 0 0.1 0.6 -0.1 06/07/2005 18:20:00 10.7 0.6 12.2 9.1 10.4 0.7 11.8 8.8 44 0 44 305 0 0.1 0.6 -0.1 06/07/2005 18:30:00 9.8 0.6 11.1 8 9.5 0.7 11.5 7.6 44 0 44 305 0 0.1 0.6 -0.1 06/07/2005 18:40:00 10 0.5 11.5 8 9.7 0.6 11.1 7.6 44 0 44 305 0 0 0.6 -0.1 06/07/2005 18:50:00 10.1 0.6 11.8 8.8 9.8 0.7 11.5 7.6 44 0 44 305 -0.1 0 0.6 -0.4 06/07/2005 19:00:00 9.9 0.8 11.5 7.6 9.6 0.8 11.5 7.6 44 0 44 305 0 0.1 0.6 -0.1 06/07/2005 19:10:00 9.9 0.6 11.1 7.2 9.6 0.7 11.1 7.2 44 0 44 305 0 0.1 0.8 -0.4 06/07/2005 19:20:00 9.7 0.6 11.5 8.4 9.4 0.6 11.1 7.6 44 0 44 305 0 0.2 0.6 -0.4 06/07/2005 19:30:00 10 0.6 11.5 8.4 9.8 0.7 11.1 8 44 0 44 305 0.1 0.1 0.8 0.1 06/07/2005 19:40:00 10.1 0.4 11.1 8.8 9.9 0.5 11.1 8.8 44 0 44 305 0 0.1 0.6 -0.1 06/07/2005 19:50:00 9.9 0.6 11.1 8 9.7 0.6 11.1 8 44 0 44 305 0 0.1 0.6 -0.1 06/07/2005 20:00:00 9.5 0.5 10.7 8 9.3 0.6 10.3 7.2 44 0 44 305 0 0 0.6 -0.1 06/07/2005 20:10:00 9 0.5 10.7 7.6 8.9 0.5 10.7 7.2 44 0 44 305 0 0.1 0.6 -0.1 06/07/2005 20:20:00 9.3 0.6 10.7 7.6 9.1 0.7 10.7 6.8 44 0 44 305 0 0.1 0.6 -0.4 06/07/2005 20:30:00 9.3 0.5 10.3 7.6 9.2 0.5 10.3 7.6 44 0 44 305 -0.1 0.1 0.6 -0.4 06/07/2005 20:40:00 9.4 0.6 10.7 8 9.2 0.6 10.7 7.6 44 0 44 305 0 0.1 0.6 -0.1 06/07/2005 20:50:00 8.8 0.5 9.9 7.2 8.6 0.6 9.5 6.8 44 0 44 305 -0.1 0.3 0.6 -0.6 06/07/2005 21:00:00 9.1 0.6 9.9 6.8 8.8 0.7 10.3 6.1 44 0 44 305 -0.3 0.1 0.3 -0.6 06/07/2005 21:10:00 8.6 0.6 9.9 6.8 8.4 0.6 9.5 6.5 44 0 44 305 -0.3 0.2 0.3 -0.6 06/07/2005 21:20:00 9 0.7 10.3 7.2 8.8 0.7 10.3 6.8 44 0 44 305 -0.4 0.1 0.1 -0.6 06/07/2005 21:30:00 9 0.8 11.1 7.2 8.8 0.8 10.7 6.8 39 5 32 305 -0.4 0.1 0.3 -0.6 06/07/2005 21:40:00 8.7 0.6 9.9 7.2 8.4 0.7 9.9 6.5 34 7 26 305 -0.5 0.1 0.1 -0.6 06/07/2005 21:50:00 9 0.5 9.9 7.6 8.8 0.5 9.9 7.2 38 5 39 305 -0.5 0 0.1 -0.6 06/07/2005 22:00:00 8.7 0.6 10.3 7.2 8.5 0.6 9.9 6.8 37 4 33 305 -0.6 0.1 0.1 -0.6 06/07/2005 22:10:00 9 0.6 10.7 7.2 8.7 0.6 10.7 6.8 42 6 47 305 -0.5 0 0.1 -0.6 06/07/2005 22:20:00 9.2 0.6 10.7 7.6 8.9 0.7 10.7 6.8 41 6 49 305 -0.7 0 -0.1 -0.8 06/07/2005 22:30:00 9.4 0.8 11.5 7.6 9.2 0.8 11.1 7.2 41 5 48 305 -0.6 0 -0.4 -0.6 06/07/2005 22:40:00 9.9 0.6 11.5 8 9.7 0.6 11.1 7.6 47 3 49 305 -0.7 0 -0.4 -0.8 06/07/2005 22:50:00 9.9 0.6 11.1 8.8 9.6 0.6 11.1 8 44 5 53 305 -0.7 0 -0.4 -0.8 06/07/2005 23:00:00 9.7 0.9 11.5 7.6 9.4 0.9 11.1 7.2 46 4 50 305 -0.8 0 -0.4 -0.8 06/07/2005 23:10:00 10.1 0.5 11.1 8.4 9.9 0.6 11.1 8 41 3 32 305 -0.9 0.1 -0.6 -1.1 06/07/2005 23:20:00 9 0.7 11.1 7.6 8.8 0.7 10.7 7.2 46 5 47 305 -0.8 0 -0.4 -1.1 06/07/2005 23:30:00 9.8 0.4 10.7 8.4 9.7 0.5 10.7 8.4 38 2 36 305 -1 0.1 -0.6 -1.1 06/07/2005 23:40:00 9.9 0.4 10.7 8.8 9.7 0.4 10.7 8 39 3 38 305 -1 0.1 -0.6 -1.1 06/07/2005 23:50:00 9.6 0.4 10.3 8.4 9.4 0.5 10.7 7.6 41 2 42 305 -1 0.1 -0.6 -1.1 06/08/2005 00:00:00 9.2 0.7 10.7 6.8 8.9 0.7 9.9 6.8 45 4 45 305 -1 0 -0.4 -1.1 06/08/2005 00:10:00 9 0.4 9.9 7.6 8.7 0.5 9.9 7.2 39 7 45 305 -1 0.1 -0.6 -1.1 06/08/2005 00:20:00 8.8 0.5 9.9 7.2 8.7 0.5 9.5 6.8 37 5 39 305 -1.1 0 -0.6 -1.3 06/08/2005 00:30:00 8.8 0.4 9.5 7.6 8.7 0.5 9.5 7.6 32 5 24 305 -1.1 0 -0.6 -1.3 06/08/2005 00:40:00 9.5 0.5 10.7 8 9.3 0.5 10.3 8 33 3 32 305 -1.1 0 -0.6 -1.3 06/08/2005 00:50:00 9.7 0.5 10.7 8.4 9.5 0.5 10.7 8 39 3 45 305 -1.1 0.1 -0.6 -1.1 06/08/2005 01:00:00 10 0.4 11.1 8.8 9.8 0.5 11.1 8 44 3 46 305 -1 0.1 -0.6 -1.1 06/08/2005 01:10:00 10.2 0.4 11.1 9.1 10 0.5 11.1 8.8 39 3 38 305 -1 0 -0.4 -1.1 06/08/2005 01:20:00 10.5 0.4 11.5 9.1 10.3 0.5 11.1 9.1 39 3 37 305 -1.1 0 -0.6 -1.1 06/08/2005 01:30:00 10.5 0.4 11.5 9.5 10.3 0.5 11.5 9.1 38 3 41 305 -1 0 -0.8 -1.1 06/08/2005 01:40:00 10.2 0.4 11.5 9.1 10 0.4 11.1 8.8 43 4 48 305 -0.9 0 -0.6 -1.1 06/08/2005 01:50:00 9.9 0.5 10.7 8.4 9.7 0.6 10.7 7.2 37 3 35 305 -1 0 -0.6 -1.1 06/08/2005 02:00:00 9.9 0.5 11.1 8.8 9.7 0.5 11.1 8.4 41 4 38 305 -0.8 0 -0.4 -1.1 06/08/2005 02:10:00 9.6 0.6 11.1 8.4 9.3 0.6 10.7 7.6 38 4 36 305 -0.8 0 -0.4 -1.1 06/08/2005 02:20:00 9.7 0.5 10.7 8.4 9.5 0.6 10.7 7.6 39 3 35 305 -0.9 0 -0.4 -1.1 06/08/2005 02:30:00 10 0.4 10.7 8.8 9.8 0.5 10.7 8.4 40 4 35 305 -0.8 0 -0.6 -1.1 06/08/2005 02:40:00 9.7 0.4 11.1 8.8 9.6 0.5 11.1 8.4 38 3 42 305 -0.8 0 -0.6 -0.8 06/08/2005 02:50:00 9.8 0.5 11.1 8.4 9.7 0.5 10.7 8.4 38 3 40 305 -0.7 0 -0.6 -0.8 06/08/2005 03:00:00 10.2 0.5 11.8 8.8 10.1 0.6 11.5 8.4 40 3 38 305 -0.7 0 -0.1 -0.8 06/08/2005 03:10:00 9.7 0.6 10.7 8 9.4 0.6 10.7 8 40 4 36 305 -0.5 0 0.1 -0.6 06/08/2005 03:20:00 9.9 0.5 11.1 8.4 9.7 0.5 11.1 8 36 4 40 305 -0.6 0 -0.1 -0.6 06/08/2005 03:30:00 9.9 0.5 11.1 8.8 9.8 0.5 11.1 8.4 42 4 38 305 -0.6 0 0.1 -0.6 06/08/2005 03:40:00 10.5 0.5 11.8 9.1 10.3 0.5 11.5 8.8 39 4 48 305 -0.5 0 -0.1 -0.6 06/08/2005 03:50:00 9.5 0.6 11.1 8 9.4 0.6 10.7 7.6 41 5 46 305 -0.5 0 0.1 -0.6 06/08/2005 04:00:00 9.8 0.5 11.1 8.4 9.6 0.6 11.1 8 42 3 48 305 -0.6 0 0.1 -0.6 06/08/2005 04:10:00 9.5 0.6 11.1 8 9.2 0.6 10.7 7.6 41 3 42 305 -0.5 0 0.1 -0.6 06/08/2005 04:20:00 9.8 0.5 11.1 8.4 9.6 0.5 10.7 8 41 4 45 305 -0.5 0 0.1 -0.6 06/08/2005 04:30:00 9.7 0.5 11.1 8 9.5 0.6 10.7 7.6 42 3 43 305 -0.5 0.1 0.1 -0.6 06/08/2005 04:40:00 10.3 0.5 11.5 8.8 10 0.5 11.5 8.8 41 4 48 305 -0.5 0.1 0.1 -0.6 06/08/2005 04:50:00 9.4 0.8 11.1 8 9.2 0.9 11.1 7.6 41 4 40 305 -0.4 0.1 0.1 -0.6 06/08/2005 05:00:00 9.2 0.5 10.7 8 9 0.5 10.7 7.6 36 4 40 305 -0.5 0 0.1 -0.6 06/08/2005 05:10:00 9.4 0.5 11.1 8 9.2 0.5 10.7 7.6 39 4 35 305 -0.4 0.1 0.1 -0.6 06/08/2005 05:20:00 9.2 0.6 10.7 7.6 9 0.7 10.3 6.8 38 5 38 305 -0.5 0.1 0.1 -0.6 06/08/2005 05:30:00 9.3 0.6 10.7 8 9.1 0.6 10.7 7.2 38 4 35 305 -0.5 0.1 0.1 -0.6 06/08/2005 05:40:00 9.6 0.6 11.1 8.4 9.4 0.6 11.1 7.6 37 4 35 305 -0.5 0.1 0.1 -0.6 06/08/2005 05:50:00 9.5 0.5 11.1 8.4 9.4 0.5 10.7 8.4 38 4 36 305 -0.4 0.1 0.1 -0.6 06/08/2005 06:00:00 9.8 0.6 11.5 8.4 9.6 0.7 11.1 8 38 3 38 305 -0.4 0 0.1 -0.6 06/08/2005 06:10:00 9.3 0.6 10.7 8 9.1 0.6 10.7 7.6 39 3 38 305 -0.3 0 0.1 -0.4 06/08/2005 06:20:00 9 0.5 10.3 8 8.8 0.6 10.3 7.2 37 3 34 305 -0.1 0 0.1 -0.4 06/08/2005 06:30:00 9.6 0.5 10.7 8 9.4 0.6 11.1 7.6 38 3 39 305 0 0 0.1 -0.1 06/08/2005 06:40:00 9.2 0.5 10.7 7.6 9 0.6 10.3 7.2 38 4 34 305 0.1 0 0.3 0.1 06/08/2005 06:50:00 9.9 0.8 12.6 8 9.7 0.8 12.2 7.2 34 3 37 305 0.2 0 0.3 0.1 06/08/2005 07:00:00 10.6 0.7 12.2 8.8 10.3 0.7 12.2 8.4 41 4 36 305 0.2 0 0.3 0.1 06/08/2005 07:10:00 9.8 0.6 11.5 8 9.7 0.6 11.1 8 41 3 42 305 0.4 0 0.6 0.3 06/08/2005 07:20:00 9.9 0.6 11.5 8.4 11.6 1.2 14.1 8.4 38 4 37 305 0.4 0 0.6 0.3 06/08/2005 07:30:00 10.9 0.8 13 8.8 11.5 0.8 14.5 9.5 37 3 37 305 0.6 0 0.8 0.6 06/08/2005 07:40:00 12 0.7 13.7 9.9 12 0.7 14.1 9.5 37 3 41 305 0.5 0 1 0.3 06/08/2005 07:50:00 11.8 0.8 14.1 9.9 11.8 0.8 14.1 9.9 36 4 33 305 0.5 0 0.6 0.3 06/08/2005 08:00:00 11.2 0.7 13 9.1 11.2 0.7 13.3 8.8 37 3 33 305 0.6 0 1 0.6 06/08/2005 08:10:00 11.3 0.7 13.3 9.9 11.2 0.7 13.3 9.1 37 4 33 305 0.9 0 1.3 0.6 06/08/2005 08:20:00 11 0.7 13.3 9.5 10.9 0.7 13.3 9.1 39 5 41 305 1.1 0 1.5 1 06/08/2005 08:30:00 11.5 0.7 13.3 9.5 11.4 0.8 13.3 9.1 40 4 39 305 1.1 0 1.5 1 06/08/2005 08:40:00 11.4 0.7 13 9.9 11.2 0.8 13 9.5 42 3 40 305 1.1 0 1.5 1 06/08/2005 08:50:00 11.6 0.6 13.3 10.3 11.4 0.7 13 9.5 41 4 32 305 1.2 0.1 1.7 1 06/08/2005 09:00:00 11.7 0.7 13.3 9.9 11.6 0.8 13.3 9.1 40 4 40 305 1.3 0.1 2 1 06/08/2005 09:10:00 12.3 0.7 14.1 10.7 12.1 0.8 14.5 10.3 41 4 41 305 1.4 0.1 2 1.3 06/08/2005 09:20:00 12 0.6 14.5 10.7 11.9 0.7 14.1 9.9 42 3 41 305 1.4 0.1 2 1.3 06/08/2005 09:30:00 11.5 0.6 13 10.3 11.4 0.6 13.3 9.9 40 4 43 305 1.4 0.1 2.2 1.3 06/08/2005 09:40:00 11.9 0.6 13.7 10.3 11.8 0.6 13.3 9.5 39 4 49 305 1.6 0 2 1.5 06/08/2005 09:50:00 11.6 0.7 13.3 9.5 11.5 0.7 13.3 8.8 40 4 36 305 1.6 0.1 2.2 1.5 06/08/2005 10:00:00 11.8 0.7 13.3 9.9 11.8 0.7 13.3 9.9 40 3 37 305 1.6 0 2.2 1.5 06/08/2005 10:10:00 11.8 0.7 13.3 9.9 11.8 0.7 14.1 9.1 40 4 34 305 1.9 0.2 2.7 1.5 06/08/2005 10:20:00 11.4 0.6 13 9.9 11.3 0.7 13 8.8 41 4 39 305 2.2 0 2.7 2 06/08/2005 10:30:00 11.5 0.7 13.3 9.9 11.4 0.8 13.3 9.5 42 3 42 305 2.2 0.1 2.7 2 06/08/2005 10:40:00 11.2 0.7 13 9.5 10.9 0.8 12.6 8.8 44 4 48 305 2.1 0 2.5 2 06/08/2005 10:50:00 11.1 0.8 13 8.8 10.9 1 13.3 8.4 42 4 38 305 2 0 2.5 2 06/08/2005 11:00:00 11 0.7 12.6 8.8 10.8 0.8 12.6 8.4 41 4 35 305 2 0.1 2.5 2 06/08/2005 11:10:00 10.6 0.6 12.2 9.1 10.4 0.7 12.2 8.4 39 4 40 305 2.2 0 2.7 2 06/08/2005 11:20:00 10.8 0.7 13.3 9.1 10.8 0.8 13 8.8 37 4 29 305 2.2 0.1 2.7 2 06/08/2005 11:30:00 11.2 0.7 13 9.5 11.1 0.7 13 9.5 36 4 35 305 2.1 0.1 2.7 2 06/08/2005 11:40:00 11.8 0.7 13.3 9.9 11.8 0.8 13.7 9.5 38 4 31 305 2.2 0.2 2.9 2 06/08/2005 11:50:00 11.8 0.9 13.7 9.9 11.7 1 13.7 9.1 38 3 33 305 2.2 0.1 2.7 2 06/08/2005 12:00:00 11.3 0.7 13 9.9 11.2 0.8 13.3 9.5 38 4 36 305 1.8 0.2 2.5 1.5 06/08/2005 12:10:00 11.3 1 13.3 8.4 11 1 13.3 8.4 40 5 41 305 1.9 0.2 2.5 1.5 06/08/2005 12:20:00 11.5 0.7 13.3 9.5 11.4 0.8 13.3 9.1 42 5 46 305 1.7 0.2 2.2 1.5 06/08/2005 12:30:00 12.1 0.7 13.7 10.3 11.9 0.8 14.1 9.5 41 4 41 305 1.6 0.1 2.2 1.3 06/08/2005 12:40:00 11.3 0.7 13 9.5 11.1 0.8 13.3 9.1 41 4 40 305 1.7 0.2 2.2 1.5 06/08/2005 12:50:00 11.4 0.8 14.1 9.9 11.2 0.9 14.1 9.1 42 4 41 305 1.9 0.2 2.5 1.5 06/08/2005 13:00:00 11.6 0.9 13.3 9.1 11.4 1 13.3 8.4 44 4 46 305 1.6 0.1 2.2 1.3 06/08/2005 13:10:00 11.5 0.8 13.3 9.1 11.4 0.9 13.7 8.4 43 3 41 305 2 0.2 2.7 1.5 06/08/2005 13:20:00 11.6 0.9 13.7 9.1 11.4 1 13.7 9.1 43 4 52 305 2.2 0.3 2.9 1.7 06/08/2005 13:30:00 11.5 0.7 13.7 9.5 11.3 0.8 13.3 9.1 42 4 41 305 1.9 0.2 2.5 1.5 06/08/2005 13:40:00 12.4 0.9 14.5 10.3 12.3 1 14.5 9.9 42 3 45 305 1.9 0.1 2.7 1.5 06/08/2005 13:50:00 13.1 0.7 14.9 11.1 13 0.8 14.9 10.7 43 3 43 305 1.5 0.2 2.5 1 06/08/2005 14:00:00 12.7 0.6 14.1 10.7 12.6 0.7 14.1 10.3 44 3 49 305 1.3 0.2 2 1 06/08/2005 14:10:00 12.8 0.8 14.5 10.7 12.6 1 14.1 9.5 43 4 41 305 1.2 0.1 1.5 1 06/08/2005 14:20:00 12.7 0.8 14.5 10.3 12.6 0.9 14.1 9.9 43 3 44 305 1.1 0.1 1.7 0.8 06/08/2005 14:30:00 12.7 0.8 14.5 10.7 12.6 0.9 14.1 10.3 43 3 45 305 0.9 0 1.3 0.8 06/08/2005 14:40:00 12.9 0.6 14.1 11.1 12.9 0.7 14.5 10.7 42 3 39 305 0.8 0 1.3 0.6 06/08/2005 14:50:00 13.4 0.7 15.3 10.7 13.3 0.8 15.3 10.7 45 3 46 305 1 0 1.5 0.8 06/08/2005 15:00:00 13.1 0.6 14.5 11.5 12.9 0.8 14.5 10.3 43 3 41 305 1.2 0.2 1.5 1 06/08/2005 15:10:00 13.3 0.6 14.9 11.5 13.1 0.7 14.9 11.1 45 3 41 305 1.2 0.1 1.5 1 06/08/2005 15:20:00 12.9 0.7 15.3 11.1 12.7 0.8 15.3 10.3 45 3 51 305 1.2 0.1 1.7 1 06/08/2005 15:30:00 13.3 0.8 15.3 11.1 13.1 1 14.9 10.3 46 3 50 305 1.2 0.1 1.7 1 06/08/2005 15:40:00 13.4 0.7 14.9 11.1 13.3 0.8 14.9 10.7 46 3 43 305 1.3 0.1 2 1 06/08/2005 15:50:00 13.6 0.8 15.3 11.1 13.3 1 15.6 10.7 47 3 47 305 1.2 0.1 1.5 1 06/08/2005 16:00:00 13.7 0.7 15.3 11.5 13.6 0.8 14.9 11.1 49 3 50 305 1.2 0.2 1.5 1 06/08/2005 16:10:00 13.3 0.6 15.3 11.8 13.1 0.8 15.6 10.7 49 3 50 305 1.3 0.2 2 1 06/08/2005 16:20:00 12.7 0.5 13.7 11.5 12.5 0.6 13.7 9.9 49 3 51 305 1.3 0.1 2 1 06/08/2005 16:30:00 12.5 0.6 14.1 11.1 12.4 0.6 14.1 10.3 49 3 47 305 1.3 0.1 1.7 1 06/08/2005 16:40:00 12.1 0.6 13.3 9.9 11.9 0.7 13.3 9.5 50 3 51 305 1.3 0.1 2 1 06/08/2005 16:50:00 12.2 0.5 13 10.7 12 0.6 13.7 10.3 49 3 45 305 1.2 0.1 1.5 1 06/08/2005 17:00:00 11.8 0.6 13 10.3 11.7 0.7 13.7 9.9 51 3 55 305 1.2 0.1 1.5 1 06/08/2005 17:10:00 11.9 0.7 13.3 9.5 11.8 0.8 13.7 9.5 51 3 51 305 1 0 1.5 0.8 06/08/2005 17:20:00 12.2 0.6 14.1 11.1 12.1 0.7 13.7 10.3 54 3 50 305 0.9 0 1.3 0.8 06/08/2005 17:30:00 11.8 0.6 13.3 9.9 11.8 0.7 13 9.5 53 3 53 305 0.9 0 1.5 0.6 06/08/2005 17:40:00 11.7 0.4 12.6 10.3 11.7 0.5 13 10.3 57 3 54 305 0.9 0 1.3 0.6 06/08/2005 17:50:00 11.7 0.5 13 10.3 11.7 0.6 13 10.3 57 3 55 305 0.9 0.1 1.3 0.6 06/08/2005 18:00:00 11.1 0.5 12.2 9.9 11.1 0.5 12.2 9.1 56 3 44 305 0.9 0.1 1.5 0.6 06/08/2005 18:10:00 10.8 0.4 12.2 9.9 10.9 0.5 12.2 9.5 57 2 61 305 0.9 0.1 1.5 0.6 06/08/2005 18:20:00 10.1 0.5 11.5 8.4 10.2 0.5 11.5 8.4 56 3 57 305 0.7 0.1 1.3 0.6 06/08/2005 18:30:00 10.1 0.5 11.5 8.8 10 0.6 11.8 8.4 58 3 61 305 0.7 0.1 1.3 0.6 06/08/2005 18:40:00 9.6 0.4 10.7 8 9.6 0.5 11.1 8 57 3 58 305 0.8 0.1 1.3 0.6 06/08/2005 18:50:00 9.7 0.5 11.5 8.4 9.7 0.5 11.1 8.4 57 3 57 305 0.7 0.1 1.3 0.6 06/08/2005 19:00:00 9.5 0.4 10.7 8.4 9.5 0.5 10.7 7.6 57 3 56 305 0.6 0.1 1.3 0.6 06/08/2005 19:10:00 9.5 0.5 10.7 8.4 9.6 0.5 11.1 8.4 57 3 55 305 0.6 0.1 1.3 0.6 06/08/2005 19:20:00 9.9 0.5 11.5 8.4 9.9 0.5 11.5 8 59 3 57 305 0.7 0.1 1.3 0.6 06/08/2005 19:30:00 9.9 0.5 11.5 8.8 9.9 0.6 11.5 7.6 59 3 62 305 0.6 0.1 1.3 0.6 06/08/2005 19:40:00 10 0.4 11.5 8.8 10 0.5 11.5 8.8 58 3 60 305 0.6 0.2 1.3 0.6 06/08/2005 19:50:00 9.7 0.5 11.1 8.8 9.8 0.5 11.5 8.8 56 3 57 305 0.6 0.2 1 0.6 06/08/2005 20:00:00 10.1 0.4 11.1 8.8 10.1 0.5 11.1 8.4 58 2 57 305 0.6 0.2 1 0.6 06/08/2005 20:10:00 9.8 0.4 10.7 8.4 9.8 0.5 10.7 8 59 2 64 305 0.7 0.2 1 0.6 06/08/2005 20:20:00 10.2 0.6 11.8 8.8 10.3 0.6 12.2 8.4 59 3 60 305 0.7 0.2 1.3 0.6 06/08/2005 20:30:00 10.6 0.5 11.8 9.1 10.6 0.6 11.8 8.8 59 3 58 305 0.7 0.2 1.3 0.6 06/08/2005 20:40:00 10.3 0.6 11.8 9.1 10.4 0.7 12.2 8.8 59 3 58 305 0.7 0.2 1.3 0.6 06/08/2005 20:50:00 10.2 0.5 11.5 8.8 10.3 0.6 11.5 8 58 3 54 305 0.6 0.2 1.3 0.6 06/08/2005 21:00:00 10.4 0.6 11.8 8.8 10.4 0.7 12.2 8.8 59 3 60 305 0.6 0.2 1 0.6 06/08/2005 21:10:00 10.4 0.6 11.8 8.8 10.4 0.7 12.6 8 60 4 62 305 0.6 0.2 1 0.6 06/08/2005 21:20:00 10.7 0.6 12.2 9.1 10.7 0.7 12.6 8.8 60 3 62 305 0.6 0.2 1.3 0.6 06/08/2005 21:30:00 10.4 0.5 11.8 8.8 10.4 0.6 12.2 8.4 61 3 60 305 0.6 0.2 1 0.6 06/08/2005 21:40:00 10.5 0.6 11.8 8.4 10.5 0.7 12.2 8.4 59 3 62 305 0.6 0.1 1 0.6 06/08/2005 21:50:00 10.9 0.4 11.8 9.5 10.9 0.5 12.2 9.1 58 3 62 305 0.6 0.1 1 0.3 06/08/2005 22:00:00 10.9 0.5 12.2 9.1 10.8 0.6 12.2 8.8 59 3 56 305 0.5 0 1 0.3 06/08/2005 22:10:00 10.7 0.5 11.8 9.5 10.7 0.5 11.8 9.1 58 3 57 305 0.6 0.1 1 0.3 06/08/2005 22:20:00 10.4 0.5 11.5 9.1 10.4 0.5 11.8 9.1 60 3 62 305 0.6 0.1 1 0.3 06/08/2005 22:30:00 10.4 0.5 12.2 8.8 10.4 0.6 11.8 8 62 4 65 305 0.6 0.1 1 0.3 06/08/2005 22:40:00 10.5 0.6 11.8 9.1 10.6 0.6 12.2 8.8 61 3 57 305 0.6 0 1 0.3 06/08/2005 22:50:00 11.2 0.4 12.2 9.9 11.3 0.5 12.6 9.9 61 3 61 305 0.5 0 1 0.3 06/08/2005 23:00:00 11.1 0.4 12.2 9.5 11.1 0.5 12.2 9.1 59 3 61 305 0.5 0 1 0.3 06/08/2005 23:10:00 11.2 0.4 12.6 9.9 11.1 0.5 12.2 9.5 59 3 63 305 0.4 0 0.8 0.3 06/08/2005 23:20:00 11.3 0.5 12.2 9.9 11.3 0.6 12.6 9.5 59 3 63 305 0.4 0 0.8 0.3 06/08/2005 23:30:00 11.2 0.5 12.6 9.5 11.1 0.6 12.6 9.1 59 3 57 305 0.4 0 1 0.3 06/08/2005 23:40:00 11.1 0.5 12.6 8.8 11.1 0.6 12.6 8.8 59 3 62 305 0.4 0 0.8 0.3 06/08/2005 23:50:00 11.5 0.5 12.6 9.9 11.6 0.6 13 9.1 60 3 62 305 0.4 0 1 0.3 06/09/2005 00:00:00 11.6 0.5 12.6 9.9 11.5 0.7 13 9.5 58 3 57 305 0.4 0 1 0.3 06/09/2005 00:10:00 11.7 0.4 13 10.7 11.6 0.6 12.6 9.9 57 2 58 305 0.4 0 0.8 0.3 06/09/2005 00:20:00 11.6 0.4 13 10.3 11.6 0.5 13 9.9 58 2 59 305 0.3 0 0.8 0.3 06/09/2005 00:30:00 11.7 0.4 12.6 10.3 11.7 0.5 12.6 9.9 58 2 58 305 0.3 0 0.8 0.3 06/09/2005 00:40:00 11.4 0.4 12.6 10.3 11.3 0.5 12.2 9.5 57 2 58 305 0.3 0 0.6 0.3 06/09/2005 00:50:00 11.3 0.3 12.2 10.3 11.3 0.4 12.2 9.9 56 2 54 305 0.3 0 0.6 0.1 06/09/2005 01:00:00 10.7 0.4 11.5 9.5 10.6 0.4 11.5 9.1 56 2 55 305 0.3 0 0.6 0.3 06/09/2005 01:10:00 9.8 0.4 10.7 8.8 9.8 0.5 10.7 8.4 55 2 56 305 0.3 0 0.8 0.1 06/09/2005 01:20:00 9.5 0.4 10.3 8 9.6 0.4 10.7 8.4 53 2 54 305 0.3 0 0.8 0.1 06/09/2005 01:30:00 9.4 0.3 10.3 8.4 9.5 0.4 10.3 8 51 2 56 305 0.3 0 0.6 0.1 06/09/2005 01:40:00 9.7 0.2 10.3 9.1 9.8 0.3 10.7 9.1 49 2 50 305 0.2 0 0.6 0.1 06/09/2005 01:50:00 10 0.3 10.7 9.1 10.1 0.4 10.7 9.1 50 2 51 305 0.2 0 0.6 0.1 06/09/2005 02:00:00 10.5 0.3 11.1 9.5 10.5 0.4 11.1 8.4 53 2 50 305 0.2 0 0.6 0.1 06/09/2005 02:10:00 10.4 0.3 11.1 9.5 10.4 0.4 11.1 9.1 55 2 54 305 0.2 0 0.3 0.1 06/09/2005 02:20:00 9.9 0.2 10.3 9.5 9.9 0.3 10.7 9.1 56 1 54 305 0.2 0 0.6 0.1 06/09/2005 02:30:00 9.8 0.3 10.7 9.1 9.9 0.3 10.7 8.8 56 2 59 305 0.2 0 0.6 0.1 06/09/2005 02:40:00 9.9 0.3 10.7 9.1 10 0.3 10.7 9.1 54 2 56 305 0.2 0 0.6 0.1 06/09/2005 02:50:00 10.4 0.3 11.1 9.5 10.5 0.4 11.5 8.8 53 2 51 305 0.2 0 0.6 0.1 06/09/2005 03:00:00 10.6 0.3 11.5 9.9 10.6 0.4 11.5 9.1 53 2 54 305 0.2 0 0.6 0.1 06/09/2005 03:10:00 10.6 0.4 11.5 9.1 10.5 0.5 11.5 8 53 2 51 305 0.2 0 0.6 0.1 06/09/2005 03:20:00 10.9 0.4 11.8 9.5 10.8 0.5 11.8 9.1 54 2 54 305 0.2 0 0.6 0.1 06/09/2005 03:30:00 11 0.4 11.8 9.9 10.9 0.5 11.8 9.1 53 2 54 305 0.2 0 0.6 0.1 06/09/2005 03:40:00 11 0.4 11.8 9.9 11.1 0.4 12.2 9.5 53 2 53 305 0.2 0 0.6 0.1 06/09/2005 03:50:00 10.9 0.5 11.8 8.4 10.9 0.6 11.8 8.4 55 2 54 305 0.2 0 0.6 0.1 06/09/2005 04:00:00 11.3 0.4 12.2 10.3 11.2 0.5 12.2 9.1 57 2 60 305 0.2 0.1 0.6 0.1 06/09/2005 04:10:00 10.8 0.4 11.8 9.1 10.6 0.5 11.8 8.8 57 2 62 305 0.2 0 0.6 0.1 06/09/2005 04:20:00 10.4 0.5 11.5 8.4 10.1 0.5 11.1 8.4 57 3 57 305 0.2 0 0.6 0.1 06/09/2005 04:30:00 10.5 0.6 11.5 8.4 10.5 0.6 11.8 8.4 58 3 54 305 0.2 0 0.6 0.1 06/09/2005 04:40:00 10.3 0.4 11.5 8.8 10.2 0.5 11.5 8.4 57 2 58 305 0.2 0 0.6 0.1 06/09/2005 04:50:00 10.2 0.5 11.5 8.4 10.1 0.6 11.1 8.4 56 2 56 305 0.3 0 0.6 0.1 06/09/2005 05:00:00 10.4 0.5 11.5 8.8 10.3 0.7 11.5 7.6 55 2 57 305 0.3 0 0.6 0.1 06/09/2005 05:10:00 10.7 0.4 11.5 9.1 10.6 0.6 11.8 8.4 55 2 54 305 0.3 0 0.6 0.1 06/09/2005 05:20:00 11.4 0.4 12.6 10.3 11.4 0.5 12.6 9.9 55 2 56 305 0.2 0 0.6 0.1 06/09/2005 05:30:00 11.6 0.4 12.6 10.7 11.7 0.4 12.6 9.9 54 2 53 305 0.2 0 0.6 0.1 06/09/2005 05:40:00 11.3 0.5 12.6 9.9 11.4 0.5 12.6 9.9 54 2 54 305 0.2 0 0.6 0.1 06/09/2005 05:50:00 10.3 0.4 11.5 9.1 10.5 0.4 11.5 8.8 54 2 58 305 0.2 0 0.6 0.1 06/09/2005 06:00:00 9.2 0.5 10.3 8 9.3 0.5 10.7 8 53 2 57 305 0.2 0 0.6 0.1 06/09/2005 06:10:00 8.4 0.4 9.5 7.2 8.5 0.5 9.9 7.2 53 2 54 305 0.2 0 0.6 0.1 06/09/2005 06:20:00 7.9 0.3 8.4 6.8 8 0.4 9.1 6.8 55 2 53 305 0.2 0 0.6 0.1 06/09/2005 06:30:00 7.7 0.4 8.4 6.1 7.8 0.4 8.8 6.1 56 2 54 305 0.3 0 0.6 0.1 06/09/2005 06:40:00 7.7 0.4 8.8 6.5 7.8 0.5 8.8 6.5 56 2 54 305 0.3 0 0.6 0.1 06/09/2005 06:50:00 7.3 0.5 8.4 5.3 7.3 0.7 8.8 5.3 53 3 56 305 0.4 0 0.8 0.3 06/09/2005 07:00:00 7.5 0.9 9.1 5.7 7.3 1.1 9.5 5.3 50 4 48 305 0.5 0 1 0.3 06/09/2005 07:10:00 9.3 0.5 10.3 8 9.4 0.6 10.7 7.6 49 3 48 305 0.4 0 0.8 0.3 06/09/2005 07:20:00 10.4 0.4 11.5 9.1 10.6 0.5 11.8 9.1 52 2 56 305 0.4 0 0.6 0.3 06/09/2005 07:30:00 10.5 0.4 11.5 9.1 10.7 0.5 11.8 9.5 52 0 52 305 0.5 0 0.8 0.3 06/09/2005 07:40:00 10.2 0.4 11.1 8.8 10.4 0.5 11.5 9.1 51 0 51 305 0.5 0 1 0.3 06/09/2005 07:50:00 10.5 0.5 11.5 9.1 10.6 0.6 11.8 9.1 51 0 51 305 0.5 0 0.8 0.3 06/09/2005 08:00:00 11 0.5 12.2 9.5 11.2 0.6 12.6 9.5 51 0 51 305 0.5 0 0.8 0.3 06/09/2005 08:10:00 10.8 0.5 11.8 9.1 10.8 0.6 12.2 8.8 51 0 51 305 0.5 0 1 0.3 06/09/2005 08:20:00 10.8 0.4 11.5 9.5 10.9 0.5 11.8 9.1 51 0 51 305 0.5 0 1 0.3 06/09/2005 08:30:00 10.2 0.4 11.5 9.1 10.5 0.4 11.5 9.1 51 0 51 305 0.5 0 1 0.6 06/09/2005 08:40:00 9.5 0.4 10.3 8.4 9.7 0.5 10.7 8.4 50 1 51 305 0.6 0.1 1 0.6 06/09/2005 08:50:00 9.2 0.5 10.7 8 9.2 0.6 10.7 7.6 50 2 49 305 0.7 0 1.3 0.6 06/09/2005 09:00:00 9.6 0.5 10.7 8 9.9 0.6 11.1 7.2 47 2 46 305 0.7 0.1 1.3 0.6 06/09/2005 09:10:00 9.3 0.4 10.3 8 9.4 0.6 10.7 7.6 46 2 45 305 0.6 0.1 1.3 0.6 06/09/2005 09:20:00 9.5 0.4 10.7 8 9.5 0.6 10.7 7.6 46 1 45 305 0.6 0.1 1.3 0.6 06/09/2005 09:30:00 9.5 0.4 10.7 8.4 9.6 0.5 10.7 8.4 48 1 48 305 0.7 0.1 1.3 0.6 06/09/2005 09:40:00 9.6 0.5 11.1 8.4 9.6 0.6 11.1 8 48 1 48 305 0.7 0.1 1.3 0.6 06/09/2005 09:50:00 9.8 0.4 10.7 8.4 9.7 0.6 11.1 8 48 0 48 305 0.7 0.1 1.3 0.6 06/09/2005 10:00:00 9.4 0.4 10.7 8.4 9.4 0.5 10.7 8 50 2 48 305 0.6 0.1 1 0.6 06/09/2005 10:10:00 9.1 0.5 10.3 7.6 9 0.6 10.7 7.2 51 2 49 305 0.8 0.1 1.3 0.6 06/09/2005 10:20:00 9.2 0.5 10.3 7.2 9 0.7 10.3 6.8 50 2 48 305 0.8 0 1.3 0.6 06/09/2005 10:30:00 9.3 0.4 10.3 8.4 9.1 0.5 10.3 7.6 46 2 49 305 0.8 0 1.3 0.6 06/09/2005 10:40:00 9.9 0.4 11.1 8.8 9.7 0.6 11.1 8 45 1 44 305 0.7 0 1.3 0.6 06/09/2005 10:50:00 9.6 0.5 11.1 8 9.5 0.6 10.7 7.6 47 2 50 305 0.9 0 1.5 0.6 06/09/2005 11:00:00 10 0.3 11.1 9.1 9.9 0.4 11.1 8.4 46 2 44 305 0.9 0.1 1.5 0.6 06/09/2005 11:10:00 9.9 0.4 11.1 9.1 9.8 0.4 11.1 8.8 44 2 47 305 0.9 0.1 1.5 0.8 06/09/2005 11:20:00 9.7 0.4 11.1 8.4 9.5 0.5 10.3 8 44 2 43 305 1 0 1.5 0.8 06/09/2005 11:30:00 9.4 0.4 10.3 8.4 9.2 0.5 10.3 7.2 43 2 45 305 1 0 1.5 0.8 06/09/2005 11:40:00 9.4 0.4 10.3 8.4 9.1 0.5 10.3 7.6 46 3 43 305 1 0.1 1.5 0.8 06/09/2005 11:50:00 9.9 0.3 10.7 9.1 9.8 0.3 10.7 8.8 48 2 48 305 1.1 0.1 1.5 1 06/09/2005 12:00:00 10.3 0.4 11.5 8.8 10.2 0.5 11.1 8.4 49 2 51 305 1.2 0.1 1.5 1 06/09/2005 12:10:00 10.7 0.3 11.5 9.5 10.5 0.4 11.5 8.4 51 2 48 305 1.2 0.1 1.7 1 06/09/2005 12:20:00 10.2 0.3 11.1 8.8 10.1 0.5 11.1 8 54 2 54 305 1.3 0.1 1.7 1 06/09/2005 12:30:00 9.5 0.4 10.3 8.4 9.3 0.5 10.3 8 53 2 51 305 1.4 0 2 1.3 06/09/2005 12:40:00 9.3 0.4 9.9 7.6 8.9 0.6 9.9 7.2 52 3 49 305 1.7 0.1 2.2 1.5 06/09/2005 12:50:00 9.5 0.4 10.3 8.4 9.2 0.5 10.3 7.6 52 2 53 305 1.6 0 2 1.5 06/09/2005 13:00:00 9.7 0.5 10.7 7.6 9.4 0.6 10.7 7.2 53 2 49 305 1.7 0.2 2.5 1.5 06/09/2005 13:10:00 9.6 0.5 10.7 8 9.4 0.7 10.7 7.2 53 3 52 305 2.2 0.2 2.9 1.7 06/09/2005 13:20:00 9.7 0.5 10.7 8 9.5 0.6 10.7 7.2 54 2 52 305 1.9 0.2 2.5 1.5 06/09/2005 13:30:00 9.5 0.5 10.7 7.6 9.2 0.7 10.7 6.8 54 3 56 305 2.3 0.2 3.2 2 06/09/2005 13:40:00 8.9 0.4 9.9 7.2 8.7 0.6 9.9 6.8 55 3 54 305 2.5 0.2 2.9 2.2 06/09/2005 13:50:00 8.2 0.6 9.5 6.1 7.9 0.7 9.5 5.7 53 3 51 305 2.2 0.1 2.9 2 06/09/2005 14:00:00 7.9 0.4 8.8 6.5 7.7 0.6 8.8 5.7 50 3 53 305 2.3 0.1 2.7 2 06/09/2005 14:10:00 7.5 0.5 8.8 5.7 7.3 0.6 8.4 5.3 51 4 53 305 2.5 0.1 2.9 2.2 06/09/2005 14:20:00 7.2 0.3 8 6.1 7.1 0.5 8 5.3 47 3 50 305 2.1 0.2 2.7 1.7 06/09/2005 14:30:00 7.4 0.3 8.4 6.8 7.4 0.4 8.4 6.1 50 2 48 305 2.2 0.1 2.7 2 06/09/2005 14:40:00 7.8 0.4 8.8 6.8 7.7 0.5 9.1 6.1 51 3 54 305 2.1 0.2 2.7 2 06/09/2005 14:50:00 8.5 0.4 9.5 6.8 8.3 0.6 9.5 6.5 55 3 59 305 2.3 0.1 2.9 2 06/09/2005 15:00:00 8.7 0.4 9.5 7.2 8.6 0.6 9.9 6.8 55 3 53 305 2.2 0.2 2.7 1.5 06/09/2005 15:10:00 8.8 0.4 9.9 7.6 8.8 0.4 10.3 6.8 55 3 58 305 2.3 0.2 2.9 2 06/09/2005 15:20:00 8.9 0.4 10.3 7.6 8.9 0.4 9.9 7.6 54 3 59 305 2.2 0.1 2.9 2 06/09/2005 15:30:00 9.1 0.6 10.7 7.6 9.1 0.6 10.7 7.2 53 5 41 305 2.2 0.1 2.7 2 06/09/2005 15:40:00 8.7 0.6 11.1 7.2 8.7 0.7 11.1 6.8 56 5 61 305 2.4 0.2 3.2 2 06/09/2005 15:50:00 8.8 0.6 10.3 7.2 8.7 0.7 10.3 6.5 55 6 62 305 2.8 0.2 3.4 2.2 06/09/2005 16:00:00 8.7 0.6 9.9 7.2 8.6 0.6 9.9 6.8 54 5 66 305 2.6 0.2 3.2 2.2 06/09/2005 16:10:00 8.6 0.5 9.9 6.8 8.6 0.6 9.9 6.5 56 5 60 305 2.3 0.1 2.9 2 06/09/2005 16:20:00 8.7 0.5 9.9 7.2 8.8 0.5 9.9 7.2 56 4 56 305 2.5 0.1 2.9 2.2 06/09/2005 16:30:00 8.3 0.6 9.9 6.8 8.4 0.6 9.9 6.8 54 5 54 305 2.3 0.2 2.9 2 06/09/2005 16:40:00 8.4 0.5 9.9 7.2 8.5 0.5 10.3 7.2 55 5 59 305 2.3 0.2 2.9 2 06/09/2005 16:50:00 8.2 0.6 9.1 6.1 8.3 0.6 9.9 6.5 55 5 53 305 2.5 0.2 3.2 2.2 06/09/2005 17:00:00 7.8 0.5 9.5 6.5 7.9 0.5 9.9 6.5 53 4 56 305 2.3 0.2 2.9 2 06/09/2005 17:10:00 7.7 0.6 9.1 6.1 7.8 0.6 9.5 5.7 55 5 56 305 2.4 0.2 2.9 2.2 06/09/2005 17:20:00 7.7 0.5 9.1 6.5 7.8 0.5 9.5 6.1 55 5 59 305 2.6 0.2 3.2 2.2 06/09/2005 17:30:00 7.6 0.5 8.8 6.5 7.7 0.6 9.1 5.7 53 4 56 305 2.5 0.2 3.2 2.2 06/09/2005 17:40:00 7.5 0.4 8.4 6.1 7.7 0.4 8.8 6.1 53 3 48 305 2.3 0.2 2.9 2 06/09/2005 17:50:00 7.1 0.4 8 6.1 7.2 0.4 8 5.3 51 3 56 305 2.2 0.1 2.7 2 06/09/2005 18:00:00 6.7 0.4 7.6 5.7 6.8 0.4 7.6 5.3 49 3 52 305 2.2 0.1 2.7 2 06/09/2005 18:10:00 6.1 0.3 6.8 4.9 6.1 0.4 6.8 4.9 49 3 53 305 2 0.2 2.5 1.5 06/09/2005 18:20:00 5.5 0.4 6.5 4.2 5.5 0.5 6.5 4.2 46 4 47 305 2 0.2 2.5 1.5 06/09/2005 18:30:00 5.2 0.2 5.7 4.6 5.3 0.3 6.1 4.6 42 2 41 305 1.9 0.2 2.5 1.5 06/09/2005 18:40:00 5.1 0.3 5.7 4.2 5 0.4 5.7 3.8 44 3 47 305 1.9 0.1 2.5 1.5 06/09/2005 18:50:00 4.8 0.3 5.3 3.8 4.9 0.3 5.7 3.8 40 3 38 305 2 0.1 2.5 1.5 06/09/2005 19:00:00 4.8 0.3 5.7 3.8 4.9 0.3 5.7 3.8 39 2 41 305 1.9 0.1 2.5 1.7 06/09/2005 19:10:00 4.9 0.2 5.7 4.2 5 0.3 5.7 4.2 38 3 40 305 1.7 0.1 2.2 1.5 06/09/2005 19:20:00 5.3 0.2 6.1 4.6 5.4 0.3 6.1 4.2 38 3 38 305 1.7 0.1 2.2 1.5 06/09/2005 19:30:00 5.1 0.2 5.7 4.6 5.3 0.3 5.7 4.2 35 3 37 305 1.7 0.1 2.2 1.3 06/09/2005 19:40:00 5.1 0.2 5.7 4.6 5.2 0.3 5.7 4.6 37 4 35 305 1.6 0.1 2.2 1.3 06/09/2005 19:50:00 4.7 0.3 5.3 3.8 4.8 0.3 5.7 3.8 33 3 36 305 1.6 0 2 1.3 06/09/2005 20:00:00 4.5 0.3 5.3 3.8 4.7 0.3 5.3 3.8 40 3 38 305 1.6 0.1 2.2 1.3 06/09/2005 20:10:00 4 0.3 4.9 3 4.1 0.4 4.9 3 39 4 42 305 1.6 0.1 2.2 1.3 06/09/2005 20:20:00 4.7 0.2 5.3 4.2 4.9 0.3 5.3 3.8 31 2 32 305 1.6 0.1 2.2 1.5 06/09/2005 20:30:00 4.7 0.3 5.3 3.4 4.8 0.3 5.3 3.4 29 2 29 305 1.6 0.1 2.2 1.3 06/09/2005 20:40:00 4.5 0.3 5.3 3.8 4.7 0.3 5.3 3.8 27 3 25 305 1.4 0 2 1.3 06/09/2005 20:50:00 4.6 0.3 5.3 3.8 4.9 0.3 5.7 3.8 22 2 21 305 1.4 0.1 2 1.3 06/09/2005 21:00:00 4.7 0.2 5.3 4.2 5 0.2 5.7 4.6 22 2 19 305 1.3 0.1 2 1.3 06/09/2005 21:10:00 4.3 0.3 4.9 3.8 4.5 0.3 5.3 3.8 21 2 21 305 1.2 0.1 1.7 1 06/09/2005 21:20:00 4.1 0.2 4.6 3.4 4.3 0.2 4.9 3.8 19 1 19 305 1.2 0.1 1.7 1 06/09/2005 21:30:00 3.9 0.2 4.6 3.4 4.1 0.3 4.6 3 17 2 18 305 1.2 0.1 1.7 1 06/09/2005 21:40:00 3.7 0.2 4.2 3.4 4 0.2 4.6 3.4 10 2 14 305 1.3 0.1 1.5 1 06/09/2005 21:50:00 3.9 0.2 4.2 3.4 4.1 0.2 4.6 3.4 5 2 5 305 1.2 0.1 1.5 1 06/09/2005 22:00:00 3.8 0.2 4.2 3.4 4 0.2 4.6 3.4 3 3 5 305 1.2 0.1 1.5 1 06/09/2005 22:10:00 3.9 0.2 4.6 3.4 4.2 0.2 4.9 3.8 355 3 353 305 1.1 0 1.5 1 06/09/2005 22:20:00 4.3 0.2 4.6 3.8 4.5 0.2 4.9 3.8 355 1 355 305 1.1 0 1.5 1 06/09/2005 22:30:00 4.4 0.2 4.9 4.2 4.7 0.2 4.9 4.2 358 1 358 305 1.1 0 1.5 1 06/09/2005 22:40:00 4.5 0.2 4.9 4.2 4.7 0.2 5.3 4.2 357 2 359 305 1.1 0 1.5 1 06/09/2005 22:50:00 4.9 0.3 5.3 4.2 5 0.3 5.7 4.2 2 2 2 305 1.1 0 1.5 1 06/09/2005 23:00:00 5 0.2 5.7 4.6 5.1 0.3 5.7 4.2 3 2 5 305 1.1 0.1 1.5 1 06/09/2005 23:10:00 5.2 0.2 5.7 4.6 5.3 0.2 5.7 4.6 5 3 4 305 1 0 1.5 1 06/09/2005 23:20:00 5.3 0.3 6.1 4.6 5.4 0.3 6.1 4.6 8 2 7 305 1 0 1.5 0.8 06/09/2005 23:30:00 5.3 0.2 6.1 4.9 5.4 0.2 6.1 4.9 6 2 8 305 0.9 0 1.3 0.8 06/09/2005 23:40:00 4.9 0.2 5.3 4.6 5.1 0.2 5.7 4.6 6 2 2 305 0.9 0 1.3 0.8 06/09/2005 23:50:00 4.8 0.2 5.3 4.2 4.8 0.2 5.3 4.2 7 1 9 305 0.8 0 1.3 0.8 06/10/2005 00:00:00 5.2 0.3 6.1 4.6 5.2 0.3 5.7 4.6 8 2 8 305 0.8 0.1 1.3 0.6 06/10/2005 00:10:00 5.1 0.3 5.7 4.6 5 0.3 5.7 4.2 9 1 12 305 0.8 0.1 1.3 0.6 06/10/2005 00:20:00 5.7 0.3 6.5 4.9 5.7 0.3 6.5 4.9 12 2 16 305 0.8 0.1 1.3 0.6 06/10/2005 00:30:00 5.3 0.5 6.5 4.2 5.3 0.4 6.5 4.6 13 2 15 305 0.9 0.1 1.3 0.6 06/10/2005 00:40:00 4.3 0.3 4.9 3.8 4.4 0.3 5.3 3.8 7 2 11 305 0.8 0.2 1.3 0.6 06/10/2005 00:50:00 4.5 0.2 5.3 3.8 4.5 0.2 4.9 4.2 8 1 12 305 0.7 0.2 1.3 0.6 06/10/2005 01:00:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3.8 11 1 12 305 0.7 0.2 1.3 0.6 06/10/2005 01:10:00 3.8 0.2 4.2 3.4 3.7 0.2 4.2 3.4 8 1 11 305 0.6 0.1 1.3 0.6 06/10/2005 01:20:00 3.2 0.5 3.8 1.9 3.3 0.4 3.8 2.3 5 3 8 305 0.6 0.1 1.3 0.6 06/10/2005 01:30:00 1.6 0.4 2.6 0.7 1.9 0.3 2.6 1.1 9 6 0 305 0.6 0.1 1 0.6 06/10/2005 01:40:00 2 0.3 2.6 1.1 2.2 0.3 2.6 1.5 14 5 8 305 0.6 0.2 1.3 0.6 06/10/2005 01:50:00 2.3 0.2 2.6 1.9 2.3 0.2 2.6 1.9 5 3 8 305 0.7 0.1 1.3 0.6 06/10/2005 02:00:00 3.2 0.4 4.2 2.3 3 0.4 3.8 2.3 1 2 359 305 0.7 0.2 1.3 0.6 06/10/2005 02:10:00 3.7 0.2 4.2 3.4 3.9 0.2 4.2 3.4 1 1 0 305 0.9 0.1 1.3 0.6 06/10/2005 02:20:00 4.1 0.2 4.6 3.4 4.1 0.2 4.6 3.4 2 2 2 305 0.9 0.1 1.3 0.6 06/10/2005 02:30:00 3.9 0.2 4.6 3.4 4 0.3 4.6 3.4 4 1 4 305 0.8 0.1 1.3 0.6 06/10/2005 02:40:00 3.3 0.3 4.2 2.6 3.1 0.3 3.8 2.6 4 2 4 305 0.8 0.1 1.3 0.6 06/10/2005 02:50:00 3.4 0.3 4.6 2.6 3 0.3 4.2 2.3 1 2 11 305 0.7 0.1 1.3 0.6 06/10/2005 03:00:00 3.4 0.2 3.8 2.6 3.3 0.3 3.8 2.6 6 1 4 305 0.8 0 1.3 0.6 06/10/2005 03:10:00 2.7 0.3 3.4 1.9 2.5 0.3 3.4 1.9 5 4 1 305 0.9 0.1 1.3 0.6 06/10/2005 03:20:00 3.2 0.2 3.4 2.6 3.2 0.2 3.8 2.6 9 1 8 305 0.9 0 1.5 0.6 06/10/2005 03:30:00 2.9 0.3 3.8 1.9 2.8 0.4 3.4 1.9 5 2 7 305 1 0 1.5 0.8 06/10/2005 03:40:00 2.9 0.3 3.4 2.3 2.6 0.3 3.4 1.9 354 2 353 305 0.9 0.1 1.5 0.8 06/10/2005 03:50:00 3.6 0.3 4.9 2.6 3.2 0.3 4.2 2.3 359 4 12 305 0.9 0 1.5 0.8 06/10/2005 04:00:00 4.1 0.4 4.9 3.4 4.1 0.4 5.3 3 18 7 11 305 1.1 0.1 1.7 0.8 06/10/2005 04:10:00 4.3 0.2 4.9 3.8 4.3 0.2 4.9 3.8 27 3 23 305 1.2 0.1 1.7 1 06/10/2005 04:20:00 3.5 0.3 4.6 3 3.6 0.3 4.6 2.6 40 6 49 305 1.1 0.1 1.7 1 06/10/2005 04:30:00 3.9 0.4 4.9 2.6 4 0.4 4.9 2.6 50 6 52 305 1.3 0.1 2 1.3 06/10/2005 04:40:00 3.8 0.5 4.9 2.6 4 0.4 4.9 3 54 6 65 305 1.4 0 2 1.3 06/10/2005 04:50:00 3.1 0.4 4.6 2.3 3.3 0.4 4.2 2.3 48 6 53 305 1.4 0 2 1.3 06/10/2005 05:00:00 2.1 0.4 3 1.5 2.5 0.3 3 1.9 52 5 37 305 1.5 0 2 1.3 06/10/2005 05:10:00 1.5 0.4 2.3 0.4 2 0.3 2.6 1.1 43 6 51 305 1.6 0.1 2 1.3 06/10/2005 05:20:00 1.2 0.3 1.9 0.7 1.7 0.2 2.3 1.1 36 8 46 305 1.6 0.1 2 1.5 06/10/2005 05:30:00 0.9 0.3 1.5 0.4 1.7 0.2 2.3 1.1 2 8 13 305 1.3 0.2 2 1 06/10/2005 05:40:00 0.4 0.1 1.1 0.4 1.2 0.2 1.9 0.7 347 6 351 305 1.2 0.1 1.5 1 06/10/2005 05:50:00 0.7 0.4 1.9 0.4 1 0.4 1.9 0.4 313 7 313 305 1.3 0.1 1.7 1 06/10/2005 06:00:00 1.6 0.6 3 0.4 1.7 0.5 2.6 0.7 313 8 316 305 1.4 0 2 1.3 06/10/2005 06:10:00 2.5 0.5 3.4 0.7 2.1 0.4 3 1.1 313 8 308 305 1.4 0 2 1.3 06/10/2005 06:20:00 1.2 0.7 3 0.4 1.4 0.5 2.6 0.4 328 14 315 305 1.6 0 2 1.3 06/10/2005 06:30:00 0.7 0.5 2.3 0.4 1 0.5 2.6 0.4 341 17 338 305 1.6 0.1 2.2 1.5 06/10/2005 06:40:00 0.5 0.3 2.3 0.4 0.8 0.4 1.9 0.4 356 21 324 305 1.6 0 2.2 1.5 06/10/2005 06:50:00 0.6 0.5 2.6 0.4 0.8 0.5 2.6 0.4 336 26 351 305 1.7 0.1 2.2 1.5 06/10/2005 07:00:00 0.5 0.4 1.9 0.4 0.7 0.4 2.3 0.4 343 17 1 305 1.7 0.1 2.2 1.5 06/10/2005 07:10:00 0.8 0.5 2.6 0.4 1 0.5 2.6 0.4 347 14 333 305 1.7 0.1 2.2 1.5 06/10/2005 07:20:00 1.6 0.9 3.8 0.4 1.6 0.7 3.8 0.4 344 10 354 305 1.6 0.1 2.2 1.5 06/10/2005 07:30:00 4.7 0.7 6.5 2.6 4.3 0.8 6.5 1.9 0 4 350 305 1.8 0.1 2.2 1.5 06/10/2005 07:40:00 5.6 0.4 6.5 4.6 5.5 0.4 6.5 4.6 355 2 353 305 2.1 0 2.5 2 06/10/2005 07:50:00 5.4 0.4 6.8 4.6 5.4 0.5 6.5 4.2 343 6 334 305 2.1 0 2.5 2 06/10/2005 08:00:00 4.9 0.3 6.1 3.8 4.8 0.4 5.7 3.4 347 4 338 305 2.2 0 2.5 2 06/10/2005 08:10:00 4.8 0.3 5.3 3.8 4.6 0.3 5.3 3.8 348 3 347 305 2 0 2.5 2 06/10/2005 08:20:00 5.6 0.3 6.1 4.2 5.5 0.4 6.5 3.8 358 2 354 305 2 0 2.5 2 06/10/2005 08:30:00 5.8 0.2 6.5 5.3 5.6 0.3 6.5 4.9 1 1 359 305 2 0 2.5 2 06/10/2005 08:40:00 5.5 0.3 6.1 4.9 5.4 0.2 6.1 4.6 7 2 2 305 1.9 0.1 2.2 1.5 06/10/2005 08:50:00 4.1 0.6 5.3 3 4.3 0.6 5.7 3 34 13 11 305 1.8 0.1 2.2 1.5 06/10/2005 09:00:00 3.7 0.3 4.2 3 3.9 0.3 4.9 2.6 46 4 48 305 1.9 0 2.5 1.5 06/10/2005 09:10:00 3.5 0.3 4.2 2.6 3.6 0.4 4.6 2.6 42 6 42 305 2 0 2.5 1.7 06/10/2005 09:20:00 2.9 0.4 3.8 1.9 3.2 0.4 4.2 2.3 35 5 41 305 2 0 2.5 1.7 06/10/2005 09:30:00 2.8 0.3 3.4 2.3 3 0.2 3.8 2.3 30 4 32 305 2.2 0.2 2.9 2 06/10/2005 09:40:00 2.4 0.4 3.4 1.1 2.7 0.3 3.4 1.9 30 6 39 305 2.3 0.1 2.7 2.2 06/10/2005 09:50:00 1.8 0.4 2.6 0.4 2.2 0.3 3 1.5 33 7 35 305 2.3 0.1 2.9 2 06/10/2005 10:00:00 1.7 0.3 2.3 0.7 2.1 0.3 2.6 1.1 30 7 21 305 2.2 0 2.5 2 06/10/2005 10:10:00 1.4 0.4 2.3 0.7 2 0.3 2.6 1.1 33 6 39 305 2.3 0.1 2.7 2.2 06/10/2005 10:20:00 1.1 0.4 2.3 0.4 1.7 0.3 2.3 1.1 33 9 28 305 2.3 0.1 2.7 2.2 06/10/2005 10:30:00 0.8 0.4 1.9 0.4 1.6 0.3 2.3 0.7 25 15 19 305 2.6 0.2 3.4 2.2 06/10/2005 10:40:00 1.1 0.5 2.3 0.4 1.7 0.4 2.6 0.4 17 15 18 305 2.9 0.2 3.4 2.7 06/10/2005 10:50:00 1 0.6 2.6 0.4 1.6 0.5 2.6 0.4 348 22 333 305 3.1 0.1 3.4 2.7 06/10/2005 11:00:00 1.5 0.5 2.6 0.4 2 0.4 3 1.1 334 12 341 305 3.4 0 3.7 3.2 06/10/2005 11:10:00 2.1 0.7 3.8 0.4 2.5 0.6 4.2 0.7 322 12 345 305 3.7 0 3.7 3.4 06/10/2005 11:20:00 2.7 0.4 3.8 1.1 2.9 0.5 3.8 1.5 320 8 317 305 3.8 0 4.2 3.7 06/10/2005 11:30:00 2.7 0.5 4.2 1.5 3 0.4 4.2 1.9 325 10 322 305 3.7 0 3.9 3.7 06/10/2005 11:40:00 2.8 0.5 4.2 1.1 3.2 0.5 4.2 1.5 329 10 313 305 3.8 0 4.2 3.7 06/10/2005 11:50:00 3 0.4 4.2 1.9 3.2 0.4 4.6 2.6 335 8 337 305 3.8 0.1 4.2 3.7 06/10/2005 12:00:00 3.3 0.4 4.2 2.3 3.5 0.4 4.6 2.6 334 8 335 305 3.9 0.1 4.2 3.7 06/10/2005 12:10:00 3.3 0.3 4.2 2.3 3.5 0.4 4.6 2.3 339 8 336 305 4 0 4.2 3.9 06/10/2005 12:20:00 3.3 0.3 4.2 2.3 3.5 0.3 4.2 2.3 341 6 339 305 3.8 0 4.2 3.4 06/10/2005 12:30:00 3.2 0.4 4.2 2.3 3.5 0.4 4.6 2.6 342 7 332 305 3.7 0.1 4.2 3.4 06/10/2005 12:40:00 3.4 0.4 4.6 2.3 3.6 0.4 4.6 2.3 348 7 358 305 3.9 0.1 4.4 3.7 06/10/2005 12:50:00 3.3 0.4 4.2 2.3 3.5 0.4 4.6 2.3 344 8 344 305 4 0 4.4 3.7 06/10/2005 13:00:00 2.9 0.4 3.8 1.9 3.2 0.4 4.6 2.3 348 8 349 305 4.1 0 4.4 3.9 06/10/2005 13:10:00 2.9 0.4 3.8 1.5 3.1 0.4 4.2 1.9 348 9 12 305 4.2 0 4.4 3.9 06/10/2005 13:20:00 3 0.4 3.8 1.9 3.3 0.4 4.2 1.9 347 7 340 305 4.1 0 4.4 3.9 06/10/2005 13:30:00 3 0.3 3.8 1.9 3.2 0.4 4.2 1.9 350 9 351 305 4 0 4.4 3.7 06/10/2005 13:40:00 2.9 0.4 3.8 1.9 3.2 0.4 4.2 2.3 355 8 352 305 4.1 0 4.4 3.9 06/10/2005 13:50:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 6 10 5 305 3.9 0.1 4.4 3.7 06/10/2005 14:00:00 2.9 0.4 3.8 1.5 3.1 0.4 4.2 1.9 6 9 13 305 3.9 0.1 4.2 3.7 06/10/2005 14:10:00 3 0.4 3.8 1.9 3.3 0.3 4.6 2.6 1 7 11 305 4.2 0 4.4 3.7 06/10/2005 14:20:00 3.3 0.5 4.9 1.9 3.5 0.4 4.9 2.3 9 9 43 305 4 0.1 4.4 3.7 06/10/2005 14:30:00 3.6 0.4 4.6 2.6 3.7 0.4 4.9 2.6 25 9 17 305 3.8 0 3.9 3.7 06/10/2005 14:40:00 3.4 0.4 4.2 2.3 3.6 0.4 4.6 2.6 27 9 41 305 3.7 0 3.9 3.4 06/10/2005 14:50:00 3.4 0.4 4.6 2.3 3.6 0.4 4.6 2.6 32 7 32 305 3.7 0 3.7 3.4 06/10/2005 15:00:00 3.1 0.3 3.8 2.3 3.3 0.3 4.2 2.6 28 7 12 305 3.7 0 3.9 3.4 06/10/2005 15:10:00 2.8 0.3 3.8 1.9 3.1 0.3 3.8 2.3 31 7 30 305 3.4 0.1 3.9 3.2 06/10/2005 15:20:00 3 0.3 3.8 1.9 3.1 0.4 4.2 1.9 34 7 27 305 3.8 0 4.2 3.7 06/10/2005 15:30:00 3 0.3 3.8 2.3 3.2 0.3 3.8 2.3 36 6 32 305 4 0 4.2 3.7 06/10/2005 15:40:00 3 0.3 3.8 2.3 3.2 0.3 3.8 2.3 30 6 32 305 4 0 4.2 3.7 06/10/2005 15:50:00 3.1 0.3 4.2 2.3 3.3 0.3 4.2 2.3 33 8 38 305 3.7 0 3.9 3.4 06/10/2005 16:00:00 3 0.4 3.8 1.9 3.2 0.4 4.2 1.9 30 8 37 305 3.7 0.2 4.2 3.4 06/10/2005 16:10:00 2.3 0.4 3 1.1 2.6 0.5 3.8 1.1 25 9 16 305 3.6 0 3.9 3.4 06/10/2005 16:20:00 1.9 0.5 3 0.7 2.3 0.4 3.4 1.1 22 11 14 305 3.7 0 4.4 3.4 06/10/2005 16:30:00 1.7 0.5 3 0.4 2.1 0.4 3 1.1 7 12 7 305 3.9 0.1 4.4 3.7 06/10/2005 16:40:00 1.7 0.5 3 0.4 2.1 0.5 3.4 0.7 6 12 2 305 3.8 0 4.2 3.7 06/10/2005 16:50:00 1.7 0.5 3 0.4 2.1 0.4 3 0.4 359 11 350 305 3.9 0.1 4.2 3.7 06/10/2005 17:00:00 1.8 0.5 3 0.7 2.1 0.4 3.4 1.1 7 10 347 305 3.7 0 3.9 3.7 06/10/2005 17:10:00 1.6 0.4 3 0.4 2 0.4 3.4 1.1 7 12 358 305 3.8 0 4.2 3.7 06/10/2005 17:20:00 1.6 0.5 2.6 0.4 2 0.4 3 1.1 8 11 6 305 3.9 0 4.2 3.7 06/10/2005 17:30:00 1.5 0.4 2.6 0.4 1.8 0.4 3 0.7 352 11 0 305 3.9 0 4.2 3.9 06/10/2005 17:40:00 1.3 0.5 2.6 0.4 1.8 0.4 2.6 1.1 352 13 9 305 3.9 0 4.2 3.7 06/10/2005 17:50:00 0.8 0.5 2.3 0.4 1.4 0.5 2.6 0.4 346 16 333 305 4.4 0.1 4.7 4.2 06/10/2005 18:00:00 1 0.4 1.9 0.4 1.5 0.4 2.6 0.4 349 13 350 305 4.5 0 4.7 4.4 06/10/2005 18:10:00 1.1 0.5 2.6 0.4 1.6 0.4 2.6 0.7 340 14 332 305 4.8 0.1 5.2 4.4 06/10/2005 18:20:00 1.4 0.6 3 0.4 1.7 0.5 3 0.4 340 17 340 305 5.5 0.2 5.9 4.9 06/10/2005 18:30:00 2 0.5 3.4 0.7 2.3 0.4 3.4 1.5 346 13 10 305 5.5 0.2 5.9 4.9 06/10/2005 18:40:00 1.5 0.6 3 0.4 2 0.4 3.4 1.1 336 17 334 305 5 0 5.4 4.9 06/10/2005 18:50:00 1.7 0.7 3 0.4 2.2 0.6 3.8 0.7 331 12 332 305 4.9 0 5.2 4.9 06/10/2005 19:00:00 1.7 0.7 3 0.4 2.2 0.6 3.4 0.7 333 11 331 305 4.8 0 4.9 4.7 06/10/2005 19:10:00 1.8 0.5 3 0.4 2.1 0.5 3.4 0.7 331 11 310 305 4.8 0 4.9 4.7 06/10/2005 19:20:00 1.8 0.4 3 0.4 2.1 0.5 3.4 0.7 336 10 0 305 4.7 0 4.9 4.7 06/10/2005 19:30:00 1.6 0.4 2.6 0.4 1.9 0.4 2.6 0.7 338 12 352 305 4.7 0 4.9 4.7 06/10/2005 19:40:00 1.5 0.4 2.6 0.4 2 0.3 3 1.1 344 12 343 305 4.5 0.2 4.9 4.2 06/10/2005 19:50:00 1.2 0.5 2.6 0.4 1.6 0.5 2.6 0.4 337 15 357 305 4.3 0 4.4 4.2 06/10/2005 20:00:00 1.4 0.5 2.6 0.4 1.8 0.4 2.6 0.4 329 13 336 305 4.4 0 4.4 4.2 06/10/2005 20:10:00 1.4 0.4 2.6 0.4 1.7 0.4 2.6 0.7 323 12 330 305 4.3 0 4.4 4.2 06/10/2005 20:20:00 1.4 0.4 2.6 0.4 1.7 0.4 3 1.1 332 12 323 305 4.3 0 4.7 4.2 06/10/2005 20:30:00 0.9 0.5 2.3 0.4 1.3 0.4 2.3 0.4 330 11 311 305 4.3 0 4.9 4.2 06/10/2005 20:40:00 1.1 0.5 2.3 0.4 1.4 0.5 2.6 0.4 322 11 330 305 4.2 0 4.7 4.2 06/10/2005 20:50:00 0.8 0.4 1.9 0.4 1.2 0.4 2.3 0.4 320 13 315 305 4.2 0 4.7 4.2 06/10/2005 21:00:00 1.1 0.5 2.3 0.4 1.4 0.4 2.3 0.4 307 15 297 305 4.3 0 4.7 4.2 06/10/2005 21:10:00 1.6 0.5 2.6 0.4 1.7 0.4 2.6 0.4 289 11 294 305 4.3 0 4.4 4.2 06/10/2005 21:20:00 1.2 0.4 2.3 0.4 1.4 0.4 2.3 0.4 279 11 287 305 4.2 0 4.4 4.2 06/10/2005 21:30:00 0.6 0.4 1.9 0.4 0.9 0.5 1.9 0.4 286 21 287 305 4.3 0 4.4 4.2 06/10/2005 21:40:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 263 21 262 305 4.4 0 4.4 4.4 06/10/2005 21:50:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 264 13 256 305 4.3 0 4.4 4.2 06/10/2005 22:00:00 0.6 0.4 1.9 0.4 0.9 0.4 1.9 0.4 264 18 289 305 4.3 0 4.4 4.2 06/10/2005 22:10:00 0.9 0.5 1.9 0.4 1.1 0.4 1.9 0.4 278 12 260 305 4.2 0 4.4 4.2 06/10/2005 22:20:00 1.2 0.5 2.3 0.4 1.2 0.4 2.3 0.4 275 13 277 305 4.2 0 4.4 4.2 06/10/2005 22:30:00 0.6 0.3 1.9 0.4 0.9 0.4 1.9 0.4 267 26 253 305 4.2 0 4.4 4.2 06/10/2005 22:40:00 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 241 19 252 305 4.2 0 4.4 4.2 06/10/2005 22:50:00 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 222 14 220 305 4.1 0 4.2 4.2 06/10/2005 23:00:00 0.6 0.4 1.9 0.4 1 0.4 1.9 0.4 230 17 227 305 4 0 4.2 3.9 06/10/2005 23:10:00 0.8 0.4 1.9 0.4 1 0.4 1.9 0.4 228 11 232 305 3.9 0 4.2 3.7 06/10/2005 23:20:00 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 222 13 239 305 3.9 0 4.2 3.7 06/10/2005 23:30:00 0.8 0.4 2.3 0.4 1.1 0.4 2.3 0.4 237 19 232 305 3.8 0 3.9 3.7 06/10/2005 23:40:00 0.7 0.4 1.9 0.4 1.1 0.4 2.3 0.4 234 16 259 305 3.7 0 3.9 3.7 06/10/2005 23:50:00 0.8 0.5 2.6 0.4 0.9 0.4 1.9 0.4 252 13 280 305 3.7 0 3.9 3.7 06/11/2005 00:00:00 0.6 0.4 2.3 0.4 0.7 0.4 1.9 0.4 245 13 232 305 3.7 0 3.9 3.7 06/11/2005 00:10:00 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 237 14 268 305 3.7 0 3.9 3.4 06/11/2005 00:20:00 0.5 0.2 1.5 0.4 0.7 0.3 1.5 0.4 250 24 257 305 3.7 0 3.9 3.7 06/11/2005 00:30:00 0.6 0.5 2.3 0.4 0.8 0.4 1.9 0.4 249 15 261 305 3.7 0 3.9 3.7 06/11/2005 00:40:00 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 252 28 275 305 3.7 0 4.2 3.7 06/11/2005 00:50:00 0.4 0.2 1.9 0.4 0.6 0.4 1.9 0.4 265 8 258 305 3.7 0 4.2 3.7 06/11/2005 01:00:00 1.3 0.6 3 0.4 1.4 0.5 2.6 0.4 253 19 266 305 3.8 0 4.2 3.7 06/11/2005 01:10:00 0.7 0.5 2.3 0.4 1 0.5 2.6 0.4 238 23 244 305 3.7 0 4.2 3.4 06/11/2005 01:20:00 0.5 0.4 2.3 0.4 0.9 0.4 2.3 0.4 234 19 236 305 3.6 0 3.9 3.4 06/11/2005 01:30:00 0.4 0.2 1.5 0.4 0.8 0.3 1.5 0.4 215 17 216 305 3.6 0 3.9 3.4 06/11/2005 01:40:00 0.6 0.4 2.3 0.4 1 0.4 1.9 0.4 233 29 277 305 3.6 0 3.9 3.4 06/11/2005 01:50:00 0.5 0.3 2.3 0.4 0.9 0.5 2.3 0.4 231 35 230 305 3.6 0 3.9 3.4 06/11/2005 02:00:00 0.5 0.3 2.6 0.4 0.6 0.4 1.9 0.4 212 47 218 305 3.6 0 3.9 3.4 06/11/2005 02:10:00 0.7 0.5 2.3 0.4 1 0.5 2.6 0.4 248 22 236 305 3.6 0 3.9 3.4 06/11/2005 02:20:00 0.8 0.5 2.3 0.4 0.9 0.4 2.3 0.4 230 28 245 305 3.6 0 4.2 3.4 06/11/2005 02:30:00 0.6 0.5 2.3 0.4 0.8 0.4 1.9 0.4 248 20 235 305 3.7 0 4.2 3.4 06/11/2005 02:40:00 0.5 0.2 1.5 0.4 0.8 0.4 1.9 0.4 235 29 198 305 3.7 0 4.2 3.4 06/11/2005 02:50:00 0.8 0.5 2.3 0.4 1.3 0.5 2.3 0.4 215 27 234 305 3.7 0 4.2 3.4 06/11/2005 03:00:00 1 0.5 2.3 0.4 1.3 0.5 2.6 0.4 219 12 202 305 3.6 0.1 4.2 3.4 06/11/2005 03:10:00 0.8 0.4 2.3 0.4 1.4 0.4 2.3 0.4 212 11 234 305 3.6 0.1 3.9 3.4 06/11/2005 03:20:00 1.1 0.5 2.3 0.4 1.5 0.5 2.6 0.4 217 19 217 305 3.6 0.1 4.2 3.4 06/11/2005 03:30:00 1.3 0.5 3 0.4 1.6 0.4 2.6 0.7 213 14 214 305 3.6 0 4.2 3.4 06/11/2005 03:40:00 1.1 0.5 2.3 0.4 1.5 0.4 2.6 0.4 217 26 227 305 3.6 0.1 4.2 3.4 06/11/2005 03:50:00 1.6 0.6 3 0.4 1.8 0.5 3.4 0.7 227 16 215 305 3.6 0 4.2 3.4 06/11/2005 04:00:00 1.1 0.5 2.3 0.4 1.5 0.5 3 0.4 213 19 228 305 3.6 0 4.2 3.4 06/11/2005 04:10:00 1.2 0.5 2.6 0.4 1.6 0.4 2.6 0.7 217 14 214 305 3.7 0 4.2 3.4 06/11/2005 04:20:00 1.6 0.4 2.3 0.7 1.9 0.4 2.6 0.7 213 10 213 305 3.6 0.1 4.2 3.4 06/11/2005 04:30:00 2.2 0.4 3 1.1 2.4 0.3 3 1.5 202 9 214 305 3.4 0.1 4.2 3.2 06/11/2005 04:40:00 2.3 0.4 3.4 1.5 2.5 0.4 3.4 1.5 210 12 237 305 3.3 0.1 3.7 3.2 06/11/2005 04:50:00 2.1 0.4 3 1.1 2.3 0.3 3 1.1 209 8 195 305 3.4 0.1 3.9 3.2 06/11/2005 05:00:00 2.2 0.3 2.6 1.5 2.6 0.3 3.4 1.5 202 5 201 305 2.8 0.2 3.7 2.5 06/11/2005 05:10:00 2 0.4 3.4 0.7 2.3 0.3 3.4 1.5 207 8 214 305 2.8 0.2 3.4 2.5 06/11/2005 05:20:00 2.2 0.3 3 1.1 2.5 0.3 3 1.9 203 5 203 305 3 0.1 3.4 2.7 06/11/2005 05:30:00 2.3 0.4 3.4 1.5 2.6 0.3 3 1.9 203 10 226 305 2.9 0.1 3.4 2.7 06/11/2005 05:40:00 2.2 0.3 3 1.5 2.5 0.2 3 1.9 208 6 206 305 3.2 0.1 3.7 2.9 06/11/2005 05:50:00 1.9 0.4 2.6 0.7 2.2 0.3 3 1.5 205 12 202 305 3.3 0 3.7 3.2 06/11/2005 06:00:00 1.8 0.3 2.6 0.7 2.2 0.3 3 1.5 207 12 205 305 3.4 0.1 3.9 3.2 06/11/2005 06:10:00 1.6 0.4 2.6 0.7 1.9 0.3 2.6 1.1 211 10 198 305 3.6 0.1 4.2 3.2 06/11/2005 06:20:00 2 0.8 3.8 0.4 2.3 0.6 4.2 0.4 212 20 210 305 3.4 0.1 3.9 3.2 06/11/2005 06:30:00 3 0.3 3.8 1.9 3.2 0.3 3.8 2.6 204 5 208 305 3.1 0.1 3.7 2.9 06/11/2005 06:40:00 3.3 0.3 3.8 2.3 3.5 0.3 4.2 2.6 205 5 207 305 2.9 0.2 3.4 2.5 06/11/2005 06:50:00 3.6 0.2 4.2 3 3.8 0.3 4.6 3 204 3 205 305 2.5 0.1 3.2 2.2 06/11/2005 07:00:00 3.3 0.4 4.2 2.6 3.5 0.4 4.6 2.6 208 2 208 305 2 0.2 2.5 1.7 06/11/2005 07:10:00 3.4 0.2 3.8 2.6 3.5 0.3 4.2 2.6 204 3 206 305 1.7 0.1 2.2 1.5 06/11/2005 07:20:00 2.4 0.4 3.4 1.5 2.7 0.4 3.4 1.1 211 7 214 305 1.6 0 2 1.5 06/11/2005 07:30:00 2.1 0.5 3 0.7 2.3 0.4 3.4 1.1 210 7 216 305 1.6 0 2 1.3 06/11/2005 07:40:00 2.1 0.7 3.4 0.7 2.4 0.6 3.4 1.1 212 7 218 305 1.3 0.1 1.7 1 06/11/2005 07:50:00 1.7 0.3 2.6 0.7 2.1 0.3 2.6 1.1 216 6 224 305 1.2 0.1 1.5 1 06/11/2005 08:00:00 1.6 0.3 2.6 0.7 1.9 0.3 2.6 1.1 223 12 218 305 1.2 0.2 1.5 1 06/11/2005 08:10:00 1.6 0.4 2.6 0.4 2 0.3 3 1.1 228 9 236 305 1.5 0.1 2 1.3 06/11/2005 08:20:00 1.7 0.4 2.6 0.7 2.1 0.4 3 1.1 222 12 214 305 1.6 0.1 2.2 1.3 06/11/2005 08:30:00 2.3 0.4 3.4 1.5 2.5 0.4 3.4 1.5 218 9 239 305 1.6 0.1 2.2 1.5 06/11/2005 08:40:00 2.8 0.4 3.8 1.5 2.9 0.4 3.8 1.9 219 12 231 305 1.4 0.2 2 1 06/11/2005 08:50:00 2.5 0.3 3.4 1.9 2.7 0.3 3.4 1.9 211 6 213 305 1 0.1 1.5 0.8 06/11/2005 09:00:00 2.9 0.3 3.4 1.9 3 0.3 3.8 1.9 217 5 216 305 1 0.2 1.5 0.8 06/11/2005 09:10:00 3.1 0.3 4.2 2.6 3.2 0.3 3.8 2.3 217 4 217 305 0.9 0.2 1.5 0.6 06/11/2005 09:20:00 3.1 0.4 3.8 2.3 3.1 0.4 4.2 1.9 213 6 216 305 0.9 0.2 1.3 0.6 06/11/2005 09:30:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 214 5 219 305 0.9 0.1 1.3 0.6 06/11/2005 09:40:00 3.2 0.5 4.2 1.9 3.2 0.4 4.2 2.3 218 6 218 305 1 0.2 1.5 0.6 06/11/2005 09:50:00 2.6 0.4 3.8 1.5 2.7 0.3 3.4 1.9 218 7 220 305 0.8 0.2 1.3 0.6 06/11/2005 10:00:00 2.3 0.5 3.4 1.1 2.5 0.4 3.4 1.1 216 9 212 305 0.8 0.2 1.3 0.6 06/11/2005 10:10:00 2 0.4 3 1.1 2.2 0.3 3 1.5 217 8 216 305 1 0 1.5 0.8 06/11/2005 10:20:00 2.1 0.4 3 0.7 2.3 0.3 3 1.5 208 10 211 305 1 0 1.3 0.8 06/11/2005 10:30:00 2.1 0.4 3.4 1.1 2.3 0.4 3.4 1.5 208 9 203 305 1 0 1.5 0.8 06/11/2005 10:40:00 2.3 0.3 3.4 1.5 2.5 0.3 3.4 1.9 213 8 218 305 0.8 0 1 0.6 06/11/2005 10:50:00 2.3 0.4 3 1.1 2.6 0.3 3.4 1.5 202 10 202 305 0.9 0 1.3 0.6 06/11/2005 11:00:00 2.4 0.4 3.4 1.1 2.6 0.3 3.4 1.5 212 8 208 305 0.8 0 1.3 0.6 06/11/2005 11:10:00 2.5 0.4 3.8 1.5 2.6 0.4 3.4 1.9 214 12 224 305 1 0 1.3 0.8 06/11/2005 11:20:00 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.1 204 11 205 305 1 0 1.5 1 06/11/2005 11:30:00 2.7 0.4 3.8 1.5 2.7 0.4 3.8 1.5 213 10 215 305 1.3 0 1.5 1 06/11/2005 11:40:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.5 214 10 213 305 1.3 0 1.5 1 06/11/2005 11:50:00 2.5 0.4 3.8 1.1 2.6 0.4 3.4 1.5 217 10 220 305 1.3 0.1 1.5 1 06/11/2005 12:00:00 2.6 0.4 3.8 1.5 2.7 0.4 3.8 1.5 216 12 221 305 1.2 0 1.5 1 06/11/2005 12:10:00 2.3 0.4 3.4 1.5 2.4 0.4 3.4 1.5 209 10 206 305 1.4 0 1.5 1.3 06/11/2005 12:20:00 2.6 0.6 4.2 1.1 2.7 0.5 4.2 1.1 211 11 232 305 1.4 0 1.5 1.3 06/11/2005 12:30:00 2.9 0.5 4.2 1.9 2.9 0.4 3.8 1.5 221 9 231 305 1.4 0 1.5 1.3 06/11/2005 12:40:00 2.7 0.5 4.2 1.1 2.8 0.4 4.2 1.9 217 14 225 305 1.6 0 2 1.5 06/11/2005 12:50:00 2.5 0.5 3.8 1.1 2.7 0.5 3.8 1.5 229 13 248 305 1.6 0 2 1.5 06/11/2005 13:00:00 2.5 0.5 3.8 1.1 2.6 0.4 3.4 1.5 218 13 215 305 1.7 0 2 1.5 06/11/2005 13:10:00 2.3 0.8 3.8 0.4 2.3 0.6 3.8 0.4 236 33 242 305 2.1 0.1 2.5 1.7 06/11/2005 13:20:00 2.1 0.7 3.8 0.4 2.3 0.6 3.8 0.4 221 24 243 305 2.5 0 2.7 2.2 06/11/2005 13:30:00 2.7 0.6 4.9 1.1 2.8 0.5 4.6 1.5 212 14 227 305 2.5 0 2.9 2.2 06/11/2005 13:40:00 2.9 0.6 5.3 1.1 2.9 0.6 6.1 1.9 222 19 232 305 2.4 0 2.7 2.2 06/11/2005 13:50:00 2.7 0.5 3.8 1.1 2.7 0.5 4.2 1.5 221 15 242 305 2.9 0.2 3.4 2.5 06/11/2005 14:00:00 2.8 0.6 4.2 1.1 2.9 0.5 4.2 1.5 214 14 215 305 2.8 0 3.2 2.7 06/11/2005 14:10:00 2.6 0.6 4.2 0.7 2.6 0.5 3.8 1.5 212 13 222 305 3.3 0.1 3.9 2.9 06/11/2005 14:20:00 3.2 0.7 4.9 1.5 3 0.7 4.6 1.5 237 23 256 305 3 0.1 3.7 2.7 06/11/2005 14:30:00 3.1 0.6 4.6 1.1 2.9 0.6 4.6 1.1 248 16 239 305 3.5 0.2 4.4 3.2 06/11/2005 14:40:00 2.8 0.6 4.2 1.5 2.6 0.7 4.6 0.7 254 17 247 305 3.3 0.2 4.2 2.9 06/11/2005 14:50:00 2.2 0.9 4.2 0.4 2 0.9 4.2 0.4 262 17 248 305 3.4 0.2 4.2 3.2 06/11/2005 15:00:00 2.9 0.7 4.9 1.5 2.7 0.7 4.2 1.1 257 17 269 305 3.4 0.1 4.2 3.2 06/11/2005 15:10:00 2.6 0.8 4.2 0.4 2.4 0.8 3.8 0.4 269 14 254 305 3.6 0.1 4.2 3.2 06/11/2005 15:20:00 1.9 0.7 3.4 0.4 2.2 0.6 3.8 0.7 215 21 223 305 3.9 0 4.4 3.7 06/11/2005 15:30:00 2.5 0.8 5.3 0.4 2.6 0.6 4.6 1.1 224 16 248 305 3.8 0 4.4 3.7 06/11/2005 15:40:00 2.8 0.7 4.9 0.7 2.6 0.6 4.2 0.7 233 23 266 305 4 0.1 4.4 3.9 06/11/2005 15:50:00 2.8 0.8 4.6 1.1 2.7 0.6 4.2 1.1 230 21 259 305 4.2 0 4.4 4.2 06/11/2005 16:00:00 3.3 0.6 4.9 1.9 2.9 0.6 4.9 1.1 263 15 268 305 3.9 0 4.2 3.7 06/11/2005 16:10:00 2.9 0.6 4.2 1.5 2.6 0.6 4.2 1.1 260 17 262 305 4 0 4.2 3.7 06/11/2005 16:20:00 3 0.6 5.3 1.9 2.8 0.5 4.6 1.5 249 16 258 305 4 0 4.2 3.7 06/11/2005 16:30:00 3 0.8 4.2 0.4 2.9 0.8 4.6 0.7 256 15 253 305 4 0 4.4 3.7 06/11/2005 16:40:00 3.2 0.6 4.6 1.5 3 0.7 4.6 1.5 256 17 242 305 4.1 0 4.4 3.9 06/11/2005 16:50:00 3 0.6 4.6 1.5 2.9 0.6 4.6 1.5 241 16 246 305 4.1 0 4.4 4.2 06/11/2005 17:00:00 3.3 0.7 4.6 1.1 3.2 0.6 4.6 1.5 238 17 242 305 3.9 0 4.2 3.7 06/11/2005 17:10:00 3.6 0.5 4.9 2.3 3.4 0.6 4.9 1.9 259 14 247 305 3.8 0 3.9 3.7 06/11/2005 17:20:00 3.5 0.8 5.7 1.9 3.3 0.8 5.3 1.5 259 12 258 305 3.9 0.1 4.2 3.7 06/11/2005 17:30:00 4 0.6 5.7 1.9 3.5 0.6 5.3 1.5 269 12 271 305 3.9 0.1 4.4 3.7 06/11/2005 17:40:00 3.3 0.6 4.9 1.9 2.9 0.6 4.9 1.5 270 13 268 305 3.9 0 4.2 3.7 06/11/2005 17:50:00 3 0.5 4.2 1.1 2.9 0.5 4.2 1.5 241 20 264 305 3.9 0.1 4.2 3.7 06/11/2005 18:00:00 3.2 0.6 4.9 1.9 3.1 0.5 4.6 1.5 229 11 242 305 3.7 0 3.9 3.4 06/11/2005 18:10:00 3.8 0.5 5.3 2.3 3.7 0.5 5.3 2.3 242 13 238 305 3.6 0 3.7 3.4 06/11/2005 18:20:00 3.8 0.6 5.3 2.3 3.5 0.6 4.9 1.5 255 11 254 305 3.7 0 3.9 3.4 06/11/2005 18:30:00 4.5 0.8 6.1 2.3 4.1 0.7 5.7 2.3 258 8 260 305 3.3 0 3.7 2.9 06/11/2005 18:40:00 5 0.7 6.5 2.6 4.2 0.8 6.1 1.9 264 8 264 305 2.8 0.1 3.2 2.5 06/11/2005 18:50:00 5 0.7 6.8 3 4.4 0.7 6.5 3 262 8 255 305 2.6 0 2.9 2.5 06/11/2005 19:00:00 5.1 0.8 7.2 2.6 4.6 0.7 6.5 2.6 261 10 264 305 2.7 0 2.9 2.5 06/11/2005 19:10:00 4.5 0.8 6.5 2.6 4 0.8 6.1 2.3 257 11 272 305 2.9 0 3.2 2.7 06/11/2005 19:20:00 4.7 0.8 6.5 2.6 4.1 0.8 6.5 2.3 259 10 256 305 2.7 0 2.9 2.7 06/11/2005 19:30:00 4.6 0.7 6.1 2.6 3.9 0.8 6.5 2.3 259 9 250 305 2.4 0.2 2.9 2.2 06/11/2005 19:40:00 4.6 0.7 6.1 2.6 4 0.7 6.1 2.3 262 9 265 305 2.2 0.1 2.7 1.7 06/11/2005 19:50:00 3.7 1 5.7 1.5 3.5 0.8 5.3 1.5 254 10 259 305 1.8 0.1 2.2 1.5 06/11/2005 20:00:00 4.4 0.8 6.1 2.6 4.1 0.8 5.7 2.3 253 10 258 305 1.9 0.1 2.2 1.5 06/11/2005 20:10:00 3.8 0.7 5.3 1.9 3.5 0.6 5.3 2.3 245 14 256 305 1.7 0.1 2.2 1.5 06/11/2005 20:20:00 3.7 0.7 4.9 1.5 3.6 0.7 4.9 1.5 246 11 243 305 1.9 0.1 2.5 1.5 06/11/2005 20:30:00 3.7 0.5 4.9 2.3 3.5 0.4 4.9 2.6 231 10 239 305 1.9 0.1 2.2 1.5 06/11/2005 20:40:00 3.6 0.7 5.3 1.5 3.3 0.7 4.9 1.5 248 12 252 305 2 0.2 2.5 1.5 06/11/2005 20:50:00 4.4 0.8 6.1 1.9 3.9 0.7 5.7 1.5 258 9 268 305 2 0 2.5 1.7 06/11/2005 21:00:00 3.1 0.6 4.6 1.5 3 0.5 4.2 1.5 236 13 266 305 2 0 2.5 2 06/11/2005 21:10:00 2.9 0.5 4.2 1.9 2.8 0.5 4.2 1.9 222 9 228 305 2 0 2.5 1.7 06/11/2005 21:20:00 4.2 0.7 5.7 2.3 3.6 0.6 5.7 2.3 267 14 277 305 2.2 0.1 2.7 2 06/11/2005 21:30:00 3.8 1 5.7 1.5 3.2 0.7 5.3 1.5 263 11 277 305 2.3 0.1 2.7 2.2 06/11/2005 21:40:00 3.1 0.6 4.9 1.9 2.7 0.6 4.6 1.5 266 15 284 305 2.3 0.1 2.7 2.2 06/11/2005 21:50:00 3.8 0.7 5.3 2.3 3.1 0.6 4.6 1.5 267 9 258 305 2.3 0.1 2.7 2.2 06/11/2005 22:00:00 3.9 0.8 6.1 2.3 3.4 0.8 5.7 1.5 273 10 283 305 2.3 0.1 2.9 2.2 06/11/2005 22:10:00 3.7 0.8 5.7 1.9 3.1 0.7 5.3 1.5 269 11 280 305 2.3 0.1 2.9 2.2 06/11/2005 22:20:00 4.9 1 6.8 1.9 4 0.8 6.5 2.3 259 7 261 305 2.2 0.1 2.7 2 06/11/2005 22:30:00 4 0.7 5.7 2.3 3.4 0.6 5.3 2.3 273 10 275 305 2.2 0.1 2.7 2 06/11/2005 22:40:00 4.2 0.7 6.1 2.3 3.7 0.7 6.1 1.9 262 12 278 305 2.2 0.1 2.7 2.2 06/11/2005 22:50:00 4.6 0.6 6.5 3 4.2 0.6 5.7 2.6 252 7 254 305 2.1 0 2.5 2 06/11/2005 23:00:00 4.2 0.4 5.7 3 3.9 0.4 5.3 2.6 246 9 251 305 2.1 0 2.5 2 06/11/2005 23:10:00 4.9 0.6 6.5 3 4.2 0.6 6.1 2.3 256 10 269 305 2.1 0 2.5 2 06/11/2005 23:20:00 4.7 0.9 6.5 2.6 3.9 0.8 6.1 1.5 259 8 261 305 2.1 0 2.5 2 06/11/2005 23:30:00 5.2 0.8 6.8 3 4.8 0.9 6.5 1.9 250 8 250 305 2.1 0 2.5 2 06/11/2005 23:40:00 5.3 0.8 6.8 3.4 4.8 0.8 6.5 2.6 249 7 255 305 2.2 0 2.5 2 06/11/2005 23:50:00 4.5 0.7 6.1 2.6 4.2 0.8 6.1 1.9 248 8 253 305 2.2 0 2.5 2 06/12/2005 00:00:00 4.7 0.6 6.1 3.4 4.3 0.7 6.5 2.6 250 8 246 305 2.2 0.1 2.5 2 06/12/2005 00:10:00 4.6 0.9 6.5 1.9 4.3 0.8 6.1 2.3 249 8 246 305 2.3 0.1 2.7 2.2 06/12/2005 00:20:00 4.8 0.7 6.5 2.6 4.5 0.7 6.5 2.6 245 9 238 305 2.3 0.1 2.7 2.2 06/12/2005 00:30:00 4.8 0.6 6.1 3 4.5 0.7 6.1 2.6 241 8 254 305 2.1 0 2.5 2 06/12/2005 00:40:00 4.1 0.7 5.7 2.6 3.7 0.7 5.3 2.3 239 7 233 305 1.9 0 2.2 1.7 06/12/2005 00:50:00 4.2 0.7 5.7 2.3 3.8 0.7 5.7 2.3 248 9 256 305 2.1 0 2.5 2 06/12/2005 01:00:00 4 0.6 5.7 2.3 3.6 0.6 4.9 2.3 245 8 240 305 2.2 0 2.5 2 06/12/2005 01:10:00 4.4 0.7 6.5 2.3 4 0.6 5.7 2.3 245 8 249 305 2.1 0.1 2.5 2 06/12/2005 01:20:00 4 0.5 5.3 2.6 3.6 0.5 5.7 2.6 244 9 239 305 2.2 0.1 2.5 2 06/12/2005 01:30:00 3.9 0.6 5.3 2.6 3.6 0.6 5.3 2.3 252 8 244 305 2.2 0.1 2.7 2 06/12/2005 01:40:00 4.1 0.7 6.1 1.9 3.7 0.7 5.3 1.9 245 10 248 305 2.2 0.1 2.7 2 06/12/2005 01:50:00 4.9 0.8 6.8 3 4.3 0.7 6.1 2.6 250 10 254 305 2.3 0.1 2.7 2.2 06/12/2005 02:00:00 4.2 0.8 6.1 1.9 3.5 0.7 5.3 1.9 262 10 259 305 2.3 0.1 2.7 2.2 06/12/2005 02:10:00 4.6 0.8 6.5 2.6 3.9 0.8 6.1 2.3 263 10 265 305 2.3 0.1 2.7 2.2 06/12/2005 02:20:00 4.3 0.7 6.1 2.3 3.5 0.7 5.3 1.9 259 8 256 305 2.3 0.2 2.7 2.2 06/12/2005 02:30:00 3.6 0.6 4.9 1.9 3.1 0.6 4.6 1.5 258 9 256 305 2.4 0.1 2.9 2.2 06/12/2005 02:40:00 4 1 5.7 1.1 3.5 0.8 5.3 1.5 257 9 258 305 2.5 0 2.9 2.2 06/12/2005 02:50:00 4.8 0.7 6.1 3 4 0.8 6.1 1.9 264 12 261 305 2.5 0 2.9 2.5 06/12/2005 03:00:00 4.6 1 7.2 2.3 3.7 0.8 6.1 1.9 265 13 257 305 2.7 0.1 3.2 2.5 06/12/2005 03:10:00 3.5 0.7 5.3 1.9 3.1 0.7 5.3 1.1 248 11 251 305 2.6 0 3.2 2.5 06/12/2005 03:20:00 4.7 1.1 7.6 2.3 4.1 0.8 6.8 2.3 255 11 262 305 2.6 0 3.2 2.5 06/12/2005 03:30:00 4.5 1.1 7.2 1.9 3.6 0.8 6.5 1.9 258 14 273 305 2.6 0 3.2 2.5 06/12/2005 03:40:00 3.2 0.7 5.3 1.5 2.9 0.5 4.6 1.1 240 10 265 305 2.3 0.1 2.9 2.2 06/12/2005 03:50:00 3.2 0.5 4.9 1.9 3 0.4 4.2 1.9 244 9 257 305 2.5 0.1 2.9 2.2 06/12/2005 04:00:00 3.6 0.7 5.3 1.9 3.1 0.5 4.6 1.9 255 13 266 305 2.5 0.1 2.9 2.2 06/12/2005 04:10:00 4.5 1.1 6.8 1.5 3.6 0.9 5.7 1.5 267 11 275 305 2.8 0.1 3.2 2.5 06/12/2005 04:20:00 3.6 0.8 5.3 1.5 3.2 0.8 5.3 1.5 250 13 260 305 2.6 0.1 3.2 2.5 06/12/2005 04:30:00 3.7 0.6 6.1 1.9 3.3 0.5 4.9 1.9 250 9 258 305 2.6 0.1 3.2 2.5 06/12/2005 04:40:00 3.3 0.6 5.3 1.9 3 0.5 4.6 1.5 254 10 269 305 2.8 0.1 3.2 2.5 06/12/2005 04:50:00 3.9 0.6 5.7 2.6 3.4 0.6 4.9 1.9 253 10 271 305 2.6 0.1 3.2 2.5 06/12/2005 05:00:00 3.7 0.5 4.9 1.9 3.4 0.5 4.9 2.3 249 8 262 305 2.6 0 3.2 2.5 06/12/2005 05:10:00 4.4 0.5 5.7 3.4 3.8 0.6 5.7 2.3 256 7 252 305 2.6 0 2.9 2.5 06/12/2005 05:20:00 4.4 0.6 5.7 2.6 3.6 0.6 4.9 2.3 264 8 251 305 2.6 0.1 3.2 2.5 06/12/2005 05:30:00 4.9 0.7 6.8 3 4 0.7 6.1 2.6 271 9 280 305 2.8 0.2 3.2 2.5 06/12/2005 05:40:00 3.2 0.6 4.6 1.9 2.7 0.6 4.2 1.5 256 11 241 305 2.8 0.1 3.2 2.5 06/12/2005 05:50:00 3.7 0.6 4.9 1.9 2.9 0.5 3.8 1.9 266 7 270 305 2.8 0.2 3.2 2.5 06/12/2005 06:00:00 3.8 0.6 5.3 2.3 3.2 0.5 4.2 1.9 258 11 275 305 2.8 0.1 3.2 2.5 06/12/2005 06:10:00 3.8 0.6 5.7 2.3 3.1 0.6 4.6 1.5 267 12 275 305 2.8 0.2 3.2 2.5 06/12/2005 06:20:00 4 0.6 5.3 1.9 3.5 0.6 5.3 1.9 257 8 268 305 2.8 0.2 3.2 2.7 06/12/2005 06:30:00 3.5 0.7 5.3 2.3 3 0.6 4.9 1.5 258 13 255 305 2.8 0.1 3.2 2.5 06/12/2005 06:40:00 3.7 0.6 4.9 1.9 3 0.5 4.2 1.9 264 8 264 305 2.8 0.1 3.2 2.7 06/12/2005 06:50:00 3.9 0.5 4.9 1.9 3.2 0.6 4.6 1.5 260 7 269 305 2.8 0.1 3.2 2.5 06/12/2005 07:00:00 4.3 0.7 5.7 1.9 3.6 0.6 5.7 2.3 257 8 262 305 2.7 0 3.2 2.5 06/12/2005 07:10:00 4.8 0.8 6.5 2.3 4 0.6 5.7 2.3 258 9 245 305 2.6 0.1 3.2 2.5 06/12/2005 07:20:00 3.8 0.6 5.7 2.3 3.3 0.7 5.3 1.9 261 10 261 305 2.6 0 3.2 2.5 06/12/2005 07:30:00 4.4 0.8 6.5 1.9 3.7 0.7 5.7 1.9 264 9 273 305 2.6 0.1 3.2 2.5 06/12/2005 07:40:00 3.3 0.8 5.3 1.5 2.8 0.7 4.6 1.1 266 10 269 305 2.8 0.1 3.2 2.5 06/12/2005 07:50:00 3 0.9 5.7 1.1 2.6 0.8 4.6 0.7 267 12 267 305 2.7 0 3.2 2.5 06/12/2005 08:00:00 4.8 1 6.8 2.3 4.1 1 6.1 1.9 277 8 281 305 2.6 0 3.2 2.5 06/12/2005 08:10:00 3.8 0.8 5.7 1.1 3 0.7 4.9 0.4 270 9 273 305 2.6 0.1 3.2 2.5 06/12/2005 08:20:00 3.3 0.8 4.9 1.5 2.7 0.6 4.6 1.1 271 12 259 305 2.6 0 3.2 2.5 06/12/2005 08:30:00 3.3 0.8 5.3 1.1 2.9 0.7 4.9 1.5 263 12 242 305 2.6 0 3.2 2.5 06/12/2005 08:40:00 3.2 0.6 4.9 1.5 2.8 0.6 4.2 1.5 263 10 259 305 2.8 0.1 3.2 2.5 06/12/2005 08:50:00 3.1 0.7 4.6 1.1 2.7 0.6 4.2 1.5 275 10 271 305 2.8 0.1 3.2 2.5 06/12/2005 09:00:00 3.2 0.6 4.9 1.9 3 0.6 4.2 1.5 279 11 263 305 2.8 0.2 3.2 2.7 06/12/2005 09:10:00 3 0.6 4.2 1.1 2.6 0.5 4.2 1.1 272 9 260 305 3 0.1 3.4 2.7 06/12/2005 09:20:00 3.2 0.7 4.9 1.5 2.9 0.5 4.6 1.5 275 9 261 305 3 0.1 3.4 2.9 06/12/2005 09:30:00 3.7 0.8 5.7 1.9 3.3 0.7 5.3 1.5 274 13 264 305 3 0.1 3.4 2.7 06/12/2005 09:40:00 3.8 0.6 4.9 1.9 3.1 0.6 4.6 1.5 272 10 270 305 2.9 0.1 3.4 2.7 06/12/2005 09:50:00 4.3 0.6 5.7 2.6 3.5 0.5 4.9 2.3 265 9 264 305 3 0.1 3.4 2.7 06/12/2005 10:00:00 3.5 0.8 5.3 1.1 3 0.7 4.9 1.5 261 8 261 305 3.1 0.1 3.4 2.9 06/12/2005 10:10:00 3.8 0.7 5.7 2.3 3.3 0.7 4.9 1.5 263 9 267 305 3 0.1 3.4 2.9 06/12/2005 10:20:00 3.8 0.6 4.9 1.9 3.2 0.5 4.9 1.5 265 9 275 305 3 0 3.4 2.9 06/12/2005 10:30:00 3.8 0.6 5.3 2.3 3.2 0.6 4.9 1.9 265 10 256 305 3 0 3.4 2.9 06/12/2005 10:40:00 3.5 0.6 5.3 1.9 3 0.6 4.6 1.5 270 9 272 305 3.1 0 3.4 2.9 06/12/2005 10:50:00 3.9 0.6 5.3 2.3 3.4 0.6 4.9 1.9 275 9 268 305 3 0 3.4 2.9 06/12/2005 11:00:00 4.2 0.5 5.7 3 3.7 0.6 5.3 2.3 273 9 275 305 3.3 0.1 3.7 2.9 06/12/2005 11:10:00 4.2 0.6 5.7 2.6 3.7 0.6 5.3 1.9 274 9 270 305 3.4 0.1 3.9 3.2 06/12/2005 11:20:00 3.1 0.8 4.9 0.7 2.9 0.7 4.9 1.5 278 16 276 305 3.4 0.2 3.9 3.2 06/12/2005 11:30:00 3 0.6 4.6 1.5 2.9 0.5 4.2 1.5 279 11 270 305 3.5 0.1 4.2 3.2 06/12/2005 11:40:00 2.9 0.6 4.9 1.5 2.8 0.6 4.6 1.5 279 11 285 305 3.6 0.2 3.9 3.2 06/12/2005 11:50:00 2.7 0.7 4.2 0.7 2.6 0.6 4.2 1.5 273 10 280 305 3.6 0.1 4.2 3.4 06/12/2005 12:00:00 2.5 0.6 3.8 0.7 2.3 0.5 3.8 1.1 266 12 259 305 3.7 0.1 4.2 3.4 06/12/2005 12:10:00 3 0.6 4.9 1.1 2.8 0.6 4.6 1.5 274 13 275 305 3.8 0 4.2 3.4 06/12/2005 12:20:00 2.9 0.6 4.6 1.5 2.7 0.5 4.2 1.1 271 10 285 305 3.9 0.1 4.4 3.7 06/12/2005 12:30:00 3.3 0.5 4.6 1.9 3.1 0.5 4.6 1.5 275 10 276 305 4 0.1 4.4 3.7 06/12/2005 12:40:00 3.6 0.7 4.9 1.5 3.2 0.6 5.3 1.5 272 10 270 305 3.9 0.1 4.4 3.7 06/12/2005 12:50:00 3.3 0.8 5.3 1.1 3 0.7 4.9 1.5 272 12 287 305 4.1 0 4.4 3.7 06/12/2005 13:00:00 3 0.7 4.6 1.5 2.8 0.6 4.2 1.1 274 11 278 305 4.2 0.1 4.4 3.7 06/12/2005 13:10:00 3.3 0.6 4.9 1.1 3.1 0.6 4.6 1.5 278 12 277 305 4.1 0.1 4.4 3.7 06/12/2005 13:20:00 3.1 0.5 4.2 1.1 2.8 0.5 4.2 1.5 274 12 287 305 4.2 0 4.7 3.9 06/12/2005 13:30:00 2.6 0.6 4.2 1.1 2.5 0.5 3.8 1.5 279 15 266 305 4.4 0.1 4.7 3.9 06/12/2005 13:40:00 2.5 0.6 3.8 0.7 2.5 0.5 3.8 1.1 276 13 269 305 4.4 0 4.7 4.2 06/12/2005 13:50:00 2.9 0.6 4.6 1.1 2.7 0.5 3.8 1.1 275 12 276 305 4.2 0 4.4 4.2 06/12/2005 14:00:00 2.5 0.7 3.8 1.1 2.6 0.6 3.8 0.7 284 12 288 305 4.4 0 4.7 4.2 06/12/2005 14:10:00 2.6 0.4 3.8 1.5 2.5 0.5 3.8 1.1 281 15 293 305 4.5 0.1 4.7 4.4 06/12/2005 14:20:00 2.6 0.7 4.2 0.7 2.5 0.6 3.8 1.1 278 11 273 305 4.4 0 4.7 4.4 06/12/2005 14:30:00 2.7 0.6 4.2 0.4 2.6 0.6 3.8 0.7 273 14 264 305 4.5 0.1 4.9 4.4 06/12/2005 14:40:00 2.7 0.6 4.2 1.1 2.6 0.6 4.6 1.5 285 13 288 305 4.8 0 4.9 4.7 06/12/2005 14:50:00 3.6 0.8 5.7 1.5 3.2 0.6 4.9 1.5 276 12 275 305 4.7 0 4.9 4.4 06/12/2005 15:00:00 3.1 0.6 4.6 1.5 3 0.6 4.2 1.5 280 12 285 305 4.5 0 4.7 4.4 06/12/2005 15:10:00 3.1 0.5 4.2 1.5 3 0.6 4.6 1.5 279 13 268 305 4.7 0 4.9 4.4 06/12/2005 15:20:00 2.8 0.5 4.2 1.5 2.7 0.5 3.8 1.5 275 15 261 305 4.7 0 4.9 4.4 06/12/2005 15:30:00 2.8 0.6 4.6 1.1 2.8 0.6 4.6 1.1 285 13 284 305 4.7 0 4.9 4.4 06/12/2005 15:40:00 3.2 0.5 4.6 2.3 3.2 0.6 4.9 1.5 285 11 293 305 4.8 0 5.2 4.4 06/12/2005 15:50:00 3.1 0.6 4.9 1.9 2.9 0.6 4.2 1.1 275 11 272 305 4.5 0 4.7 4.4 06/12/2005 16:00:00 2.8 0.6 4.6 1.1 2.7 0.6 4.6 1.5 276 17 272 305 4.5 0 4.7 4.4 06/12/2005 16:10:00 2.9 0.5 4.6 1.9 2.8 0.5 4.2 1.5 282 11 285 305 4.6 0 4.7 4.4 06/12/2005 16:20:00 2.8 0.6 4.6 0.7 2.7 0.6 4.2 0.4 283 12 277 305 4.5 0 4.7 4.4 06/12/2005 16:30:00 3 0.5 4.2 1.1 3 0.5 4.2 1.1 290 13 294 305 4.7 0 4.9 4.4 06/12/2005 16:40:00 3 0.5 4.2 1.1 3 0.6 4.2 1.1 289 13 285 305 4.5 0 4.7 4.4 06/12/2005 16:50:00 3.3 0.5 4.6 1.9 3 0.6 4.6 1.5 280 13 285 305 4.4 0 4.4 4.4 06/12/2005 17:00:00 3.3 0.6 5.3 1.5 3.2 0.6 4.9 1.5 280 12 281 305 4.4 0 4.7 4.4 06/12/2005 17:10:00 3.8 0.5 4.9 2.3 3.8 0.5 5.3 2.3 291 11 276 305 4.4 0 4.7 4.2 06/12/2005 17:20:00 3.5 0.6 4.9 1.9 3.4 0.7 4.9 1.5 280 12 288 305 4.5 0 4.7 4.4 06/12/2005 17:30:00 3.2 0.6 4.9 1.9 3.1 0.5 4.6 1.9 288 15 271 305 4.4 0 4.4 4.2 06/12/2005 17:40:00 3.2 0.6 4.9 1.9 3.1 0.6 4.9 1.9 291 15 298 305 4.2 0 4.4 4.2 06/12/2005 17:50:00 2.6 0.6 4.2 0.7 2.5 0.7 4.6 1.1 288 16 305 305 4.2 0 4.4 4.2 06/12/2005 18:00:00 3 0.7 4.9 1.1 3 0.6 4.9 1.5 296 13 300 305 4.3 0 4.4 4.2 06/12/2005 18:10:00 3 0.5 4.6 1.5 3.1 0.5 4.6 1.9 300 13 307 305 4.2 0 4.4 3.9 06/12/2005 18:20:00 2.7 0.5 4.2 1.1 2.6 0.6 4.2 1.1 285 17 273 305 4.2 0 4.4 3.7 06/12/2005 18:30:00 2.2 0.7 4.2 0.4 2.3 0.6 3.8 0.7 292 20 298 305 4.2 0 4.4 3.9 06/12/2005 18:40:00 2.3 0.7 3.8 0.7 2.2 0.6 4.2 0.7 284 19 275 305 4 0.1 4.4 3.7 06/12/2005 18:50:00 2.4 0.7 3.8 0.4 2.3 0.6 3.8 0.7 285 17 288 305 4.2 0 4.4 4.2 06/12/2005 19:00:00 1.4 0.8 3.8 0.4 1.5 0.8 3.4 0.4 293 16 302 305 4 0.1 4.4 3.9 06/12/2005 19:10:00 1.7 0.7 3.4 0.4 1.9 0.5 3 0.7 297 19 273 305 4 0 4.2 3.7 06/12/2005 19:20:00 1.7 0.6 3.4 0.4 2 0.4 3 0.4 313 12 321 305 3.8 0 3.9 3.7 06/12/2005 19:30:00 1.7 0.6 3.4 0.4 1.9 0.5 3.4 0.4 295 15 319 305 3.8 0 4.2 3.7 06/12/2005 19:40:00 1.2 0.8 3.4 0.4 1.4 0.7 3.4 0.4 269 19 299 305 3.7 0 4.2 3.4 06/12/2005 19:50:00 2.3 0.6 3.8 0.7 2.3 0.6 3.8 1.1 263 21 215 305 3.6 0 3.7 3.4 06/12/2005 20:00:00 2.3 0.5 3.4 0.4 2.2 0.6 3.4 0.7 253 12 248 305 3.3 0 3.7 3.2 06/12/2005 20:10:00 2.9 0.5 4.2 1.5 2.8 0.5 4.2 1.5 277 12 282 305 3.4 0 3.7 3.2 06/12/2005 20:20:00 2.3 0.6 3.8 1.1 2.2 0.6 3.4 0.7 273 15 282 305 3.3 0 3.7 3.2 06/12/2005 20:30:00 2.6 0.8 4.2 0.7 2.4 0.8 4.2 0.7 277 9 283 305 3.3 0 3.4 3.2 06/12/2005 20:40:00 2.7 0.5 3.8 0.7 2.4 0.6 3.8 0.7 268 10 272 305 3.2 0 3.4 2.9 06/12/2005 20:50:00 2.2 0.8 3.8 0.4 2.1 0.6 3.4 0.7 280 13 267 305 3.1 0 3.4 2.9 06/12/2005 21:00:00 1.9 0.6 4.6 0.4 1.9 0.6 3.4 0.7 279 17 287 305 3.2 0 3.7 2.9 06/12/2005 21:10:00 1.6 0.8 3.4 0.4 1.5 0.6 3 0.4 267 9 250 305 3.1 0.1 3.4 2.9 06/12/2005 21:20:00 1.4 0.6 2.3 0.4 1.4 0.6 2.6 0.4 290 17 283 305 3 0 3.4 2.9 06/12/2005 21:30:00 1.2 0.5 2.3 0.4 1.4 0.5 2.6 0.4 275 21 272 305 2.9 0.1 3.4 2.7 06/12/2005 21:40:00 1.6 0.5 2.6 0.4 1.5 0.4 2.6 0.7 265 18 265 305 2.9 0.2 3.2 2.7 06/12/2005 21:50:00 1.5 0.5 2.6 0.4 1.8 0.5 3 0.7 291 13 270 305 2.9 0.1 3.4 2.7 06/12/2005 22:00:00 1.5 0.7 2.6 0.4 1.7 0.7 3 0.4 296 18 296 305 2.8 0.2 3.2 2.5 06/12/2005 22:10:00 1 0.5 2.3 0.4 1.2 0.5 2.6 0.4 292 22 279 305 2.7 0 3.2 2.5 06/12/2005 22:20:00 0.7 0.5 2.3 0.4 0.9 0.6 2.3 0.4 305 19 314 305 2.7 0.1 3.2 2.5 06/12/2005 22:30:00 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 312 22 320 305 2.8 0.1 3.2 2.5 06/12/2005 22:40:00 1.1 0.6 3 0.4 1.6 0.6 3 0.4 309 13 305 305 2.7 0.1 3.2 2.5 06/12/2005 22:50:00 0.9 0.6 2.6 0.4 1.2 0.6 3 0.4 328 18 305 305 2.5 0.1 3.2 2.2 06/12/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 322 7 305 305 2.5 0.1 2.9 2.2 06/12/2005 23:10:00 1.6 0.6 2.6 0.4 1.9 0.6 3 0.4 306 9 320 305 2.6 0 3.2 2.2 06/12/2005 23:20:00 1.7 0.4 2.6 0.4 2 0.4 3 0.7 296 12 300 305 2.5 0.2 3.2 2.2 06/12/2005 23:30:00 1 0.7 2.6 0.4 1.2 0.8 2.6 0.4 290 13 302 305 2.3 0.1 2.9 2.2 06/12/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 311 56 305 305 2.2 0 2.5 2.2 06/12/2005 23:50:00 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 26 9 16 305 2.3 0.1 2.7 2.2 06/13/2005 00:00:00 0.4 0.3 2.3 0.4 0.7 0.5 2.3 0.4 337 64 334 305 2.3 0.2 2.7 2.2 06/13/2005 00:10:00 0.5 0.4 1.9 0.4 0.8 0.6 2.6 0.4 296 9 306 305 2.3 0.1 2.7 2.2 06/13/2005 00:20:00 0.5 0.3 1.9 0.4 1 0.5 2.3 0.4 313 8 303 305 2.2 0 2.5 2 06/13/2005 00:30:00 0.5 0.2 1.1 0.4 0.9 0.3 1.5 0.4 322 18 327 305 2.2 0 2.5 2 06/13/2005 00:40:00 0.4 0.1 1.1 0.4 0.7 0.4 1.9 0.4 332 11 340 305 2.2 0 2.5 2 06/13/2005 00:50:00 0.6 0.3 1.5 0.4 1 0.4 1.9 0.4 319 12 331 305 2.2 0.1 2.5 2 06/13/2005 01:00:00 0.6 0.4 1.9 0.4 1 0.6 1.9 0.4 299 15 305 305 2.2 0 2.5 2 06/13/2005 01:10:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 314 1 305 305 2.2 0 2.5 2 06/13/2005 01:20:00 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 316 0 316 305 2.2 0.1 2.7 2.2 06/13/2005 01:30:00 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 330 15 305 305 2.2 0 2.5 2 06/13/2005 01:40:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 352 8 305 305 2.1 0 2.5 2 06/13/2005 01:50:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 26 19 61 305 2 0 2.5 2 06/13/2005 02:00:00 0.4 0.2 1.9 0.4 0.7 0.5 1.9 0.4 28 20 59 305 1.9 0.2 2.5 1.7 06/13/2005 02:10:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 104 32 60 305 1.8 0.2 2.2 1.5 06/13/2005 02:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 88 39 305 305 1.8 0.2 2.2 1.5 06/13/2005 02:30:00 0.4 0.1 0.7 0.4 0.7 0.3 1.5 0.4 38 0 38 305 1.8 0.2 2.2 1.5 06/13/2005 02:40:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 38 0 305 305 1.7 0.2 2.2 1.5 06/13/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 305 305 1.7 0.1 2.2 1.5 06/13/2005 03:00:00 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 27 8 25 305 1.7 0.2 2.2 1.5 06/13/2005 03:10:00 1.2 0.3 1.5 0.4 1.4 0.3 1.9 0.4 44 6 46 305 1.7 0.1 2.2 1.5 06/13/2005 03:20:00 1 0.3 1.9 0.7 1.5 0.2 1.9 1.1 46 2 48 305 1.7 0.2 2.2 1.5 06/13/2005 03:30:00 2.1 0.4 2.6 1.1 2.4 0.4 3 1.5 37 2 35 305 1.7 0.1 2.2 1.5 06/13/2005 03:40:00 2.7 0.3 3.4 2.3 3 0.3 3.4 2.6 38 4 42 305 1.7 0.1 2.2 1.5 06/13/2005 03:50:00 3.5 0.2 3.8 3 3.8 0.3 4.2 3 39 3 36 305 1.6 0.1 2.2 1.5 06/13/2005 04:00:00 4 0.2 4.6 3.4 4.2 0.2 4.6 3.4 40 2 39 305 1.7 0.2 2.2 1.5 06/13/2005 04:10:00 4.7 0.3 5.3 3.8 4.8 0.2 5.3 4.2 41 3 42 305 1.7 0.2 2.2 1.5 06/13/2005 04:20:00 4 0.5 4.9 3 4.2 0.5 4.9 3.4 38 4 45 305 1.7 0.2 2.2 1.5 06/13/2005 04:30:00 2.9 0.4 3.8 1.9 3.1 0.5 3.8 1.9 38 7 34 305 1.7 0.2 2.2 1.5 06/13/2005 04:40:00 1.9 0.4 2.6 0.7 2.3 0.3 3 1.5 46 6 44 305 1.8 0.2 2.2 1.5 06/13/2005 04:50:00 1 0.6 2.3 0.4 1.3 0.7 2.6 0.4 25 15 10 305 1.7 0.2 2.2 1.5 06/13/2005 05:00:00 1.7 0.4 2.6 1.1 2.1 0.3 3 1.5 17 8 9 305 1.7 0.2 2.2 1.5 06/13/2005 05:10:00 2.1 0.3 2.6 1.5 2.4 0.2 3 1.9 48 6 33 305 1.8 0.2 2.5 1.5 06/13/2005 05:20:00 2.6 0.3 3 1.9 2.8 0.2 3.4 2.3 37 5 36 305 1.7 0.2 2.2 1.5 06/13/2005 05:30:00 3.1 0.2 3.4 2.6 3.3 0.2 3.8 2.6 28 2 27 305 1.7 0.1 2.2 1.5 06/13/2005 05:40:00 3.3 0.4 4.2 2.6 3.5 0.4 4.2 2.6 37 7 40 305 1.7 0.2 2.2 1.5 06/13/2005 05:50:00 3.1 0.2 3.4 2.6 3.4 0.2 3.8 3 20 3 27 305 1.7 0.2 2.2 1.5 06/13/2005 06:00:00 2.6 0.2 3 1.9 2.8 0.2 3.4 2.3 26 3 23 305 1.8 0.2 2.2 1.5 06/13/2005 06:10:00 3 0.3 3.4 2.6 3.2 0.2 3.8 2.6 30 1 29 305 1.7 0.1 2.2 1.5 06/13/2005 06:20:00 3.3 0.3 3.8 2.6 3.5 0.3 4.2 3 34 2 33 305 1.7 0.1 2.2 1.5 06/13/2005 06:30:00 3.8 0.2 4.2 3.4 3.9 0.2 4.2 3.4 38 2 35 305 1.9 0.2 2.2 1.5 06/13/2005 06:40:00 3.3 0.2 3.8 3 3.5 0.2 4.2 3 36 3 41 305 1.9 0.1 2.2 1.7 06/13/2005 06:50:00 3.6 0.2 3.8 3 3.7 0.2 4.2 3.4 37 1 36 305 1.9 0 2.5 1.7 06/13/2005 07:00:00 3.5 0.2 3.8 3 3.6 0.2 4.2 3 38 2 38 305 2 0.1 2.5 2 06/13/2005 07:10:00 3.6 0.2 4.2 3 3.8 0.2 4.2 3 32 1 32 305 2.1 0.1 2.7 2 06/13/2005 07:20:00 3.5 0.2 3.8 3 3.7 0.2 4.2 3.4 32 2 38 305 2.2 0.1 2.7 2 06/13/2005 07:30:00 4 0.2 4.6 3.4 4.2 0.2 4.9 3.8 30 2 28 305 2.2 0.1 2.7 2.2 06/13/2005 07:40:00 4.5 0.3 5.3 3.8 4.6 0.3 5.3 4.2 33 2 37 305 2.3 0.2 2.7 2.2 06/13/2005 07:50:00 5.3 0.2 6.1 4.6 5.3 0.2 5.7 4.6 30 3 30 305 2.4 0.2 2.9 2.2 06/13/2005 08:00:00 5.1 0.3 6.1 4.6 5.1 0.3 6.1 4.2 31 3 29 305 2.3 0.1 2.9 2.2 06/13/2005 08:10:00 5.3 0.3 6.1 4.9 5.4 0.3 6.1 4.6 28 2 32 305 2.5 0.1 2.9 2.2 06/13/2005 08:20:00 5.5 0.5 6.5 2.6 5.5 0.5 6.8 3 33 5 28 305 2.7 0.1 3.2 2.5 06/13/2005 08:30:00 5.8 0.3 6.5 4.9 5.9 0.4 6.5 4.6 36 2 37 305 2.8 0.1 3.2 2.7 06/13/2005 08:40:00 6.5 0.3 6.8 5.7 6.6 0.3 7.2 5.7 35 1 35 305 2.8 0.1 3.2 2.7 06/13/2005 08:50:00 6.7 0.2 7.2 6.1 6.8 0.2 7.2 6.1 30 1 32 305 2.7 0 3.2 2.5 06/13/2005 09:00:00 6.6 0.2 6.8 6.1 6.7 0.2 7.2 6.1 30 1 28 305 2.6 0 3.2 2.5 06/13/2005 09:10:00 6.1 0.3 6.8 5.3 6.1 0.3 6.8 5.3 32 1 31 305 2.6 0.1 3.2 2.5 06/13/2005 09:20:00 5.2 0.3 6.1 4.6 5.3 0.3 5.7 4.6 30 2 33 305 2.6 0 3.2 2.5 06/13/2005 09:30:00 5.1 0.3 5.7 4.6 5.2 0.3 6.1 4.6 26 2 22 305 2.7 0 3.2 2.5 06/13/2005 09:40:00 5 0.2 5.7 4.6 5.1 0.3 5.7 4.6 26 3 24 305 2.9 0.2 3.4 2.7 06/13/2005 09:50:00 5.3 0.2 5.7 4.6 5.3 0.3 5.7 4.6 28 2 27 305 3.2 0.1 3.7 2.9 06/13/2005 10:00:00 5.5 0.2 6.1 4.9 5.5 0.3 6.1 4.6 31 3 29 305 3.4 0.1 4.2 3.2 06/13/2005 10:10:00 5.2 0.3 5.7 4.2 5.3 0.3 6.1 4.2 24 5 30 305 3.6 0.1 4.2 3.4 06/13/2005 10:20:00 4.8 0.3 5.7 4.2 4.9 0.4 5.7 3.8 18 3 16 305 3.8 0.2 4.4 3.4 06/13/2005 10:30:00 4.7 0.3 5.7 3.4 4.6 0.4 5.7 3.4 22 4 23 305 3.9 0.1 4.4 3.7 06/13/2005 10:40:00 5.6 0.5 6.5 4.6 5.6 0.5 6.8 4.6 29 5 27 305 4.2 0.3 4.9 3.7 06/13/2005 10:50:00 5.9 0.4 6.8 4.6 6.3 0.4 7.2 5.3 41 4 38 305 4.7 0.1 5.2 4.4 06/13/2005 11:00:00 6 0.6 7.2 4.2 6.5 0.5 7.6 4.6 45 5 45 305 5 0.1 5.4 4.7 06/13/2005 11:10:00 6.3 0.6 8 4.6 6.3 0.7 7.6 4.2 59 12 71 305 5.5 0.4 6.4 4.7 06/13/2005 11:20:00 6.7 0.8 8.8 4.6 6.6 0.8 8 4.6 64 9 74 305 6.3 0.4 7.2 5.6 06/13/2005 11:30:00 7.8 0.5 8.8 6.5 7.9 0.4 8.8 6.8 53 4 63 305 5.3 0.2 6.1 4.9 06/13/2005 11:40:00 8.1 0.2 8.8 7.6 8 0.3 8.8 7.2 51 3 51 305 5 0.2 5.6 4.7 06/13/2005 11:50:00 7.9 0.3 8.4 7.2 7.7 0.4 8.4 6.1 52 3 51 305 5.3 0.1 5.6 4.9 06/13/2005 12:00:00 7.2 0.6 8.4 5.7 7 0.6 8.4 5.3 50 3 51 305 5.2 0.1 5.6 4.9 06/13/2005 12:10:00 6.3 0.4 7.2 5.3 6.2 0.4 6.8 5.3 43 4 45 305 4.8 0 5.2 4.7 06/13/2005 12:20:00 5.6 0.4 6.5 4.9 5.6 0.3 6.5 4.9 40 2 43 305 4.8 0 4.9 4.7 06/13/2005 12:30:00 5.5 0.3 6.5 4.9 5.4 0.3 6.1 4.6 36 4 43 305 5 0 5.4 4.9 06/13/2005 12:40:00 5.1 0.2 5.7 4.6 5.2 0.2 5.7 4.6 32 3 41 305 4.9 0 5.2 4.7 06/13/2005 12:50:00 5.4 0.3 6.1 4.9 5.5 0.3 6.1 4.9 32 2 31 305 4.8 0 5.2 4.7 06/13/2005 13:00:00 5.8 0.3 6.5 5.3 5.9 0.3 6.8 5.3 34 2 35 305 4.9 0 5.4 4.7 06/13/2005 13:10:00 5.9 0.2 6.5 5.3 6 0.3 6.5 5.3 36 2 39 305 5.3 0 5.4 4.9 06/13/2005 13:20:00 6.2 0.3 6.8 5.3 6.2 0.3 6.8 5.3 42 3 39 305 5.4 0.1 5.6 5.2 06/13/2005 13:30:00 6.5 0.3 7.2 5.7 6.6 0.3 7.2 5.7 45 3 44 305 5.3 0 5.4 4.9 06/13/2005 13:40:00 6.7 0.3 7.2 5.3 6.8 0.4 7.6 5.3 43 3 40 305 5.3 0 5.6 4.9 06/13/2005 13:50:00 6.5 0.2 7.2 5.7 6.7 0.3 7.6 5.7 41 3 39 305 5.3 0.1 5.6 4.9 06/13/2005 14:00:00 6.7 0.3 7.6 6.1 6.9 0.3 7.6 5.7 43 3 42 305 5.4 0 5.6 5.2 06/13/2005 14:10:00 7 0.3 8 6.5 7.1 0.3 8 6.1 47 3 52 305 5.5 0.1 5.9 5.2 06/13/2005 14:20:00 6.8 0.3 7.6 6.1 6.9 0.4 8.4 5.7 46 3 51 305 5.4 0 5.9 5.2 06/13/2005 14:30:00 6.4 0.3 7.2 5.7 6.5 0.3 7.2 5.7 42 3 52 305 5.4 0 5.6 4.9 06/13/2005 14:40:00 6.5 0.2 7.2 5.7 6.6 0.2 7.2 5.7 43 3 36 305 5.4 0 5.6 5.2 06/13/2005 14:50:00 6.4 0.2 6.8 5.7 6.5 0.2 7.2 5.7 45 3 44 305 5.6 0.1 5.9 5.4 06/13/2005 15:00:00 6.3 0.2 6.8 5.7 6.6 0.3 7.2 5.7 50 3 46 305 5.5 0.1 5.9 5.2 06/13/2005 15:10:00 6.4 0.3 7.2 5.3 6.9 0.3 7.6 5.7 51 3 53 305 5.8 0 6.1 5.6 06/13/2005 15:20:00 6.1 0.2 6.8 5.7 6.9 0.3 7.6 6.1 54 3 51 305 6 0 6.1 5.9 06/13/2005 15:30:00 5.9 0.3 6.5 4.9 6.7 0.3 7.2 5.7 52 3 57 305 6.3 0 6.4 5.9 06/13/2005 15:40:00 6.4 0.4 7.2 5.3 6.8 0.3 7.6 6.1 53 3 46 305 6.2 0.1 6.7 5.9 06/13/2005 15:50:00 6.5 0.3 7.2 5.7 6.9 0.2 7.6 6.1 50 3 51 305 6.2 0.1 6.4 5.9 06/13/2005 16:00:00 6.5 0.3 7.2 6.1 7 0.3 7.6 6.5 52 3 54 305 6 0 6.4 5.6 06/13/2005 16:10:00 6.5 0.3 7.2 5.7 6.8 0.3 7.6 6.1 55 3 54 305 5.7 0 6.1 5.4 06/13/2005 16:20:00 6.6 0.3 7.2 5.7 6.9 0.3 7.6 6.1 54 2 53 305 5.6 0.2 6.4 5.4 06/13/2005 16:30:00 6.9 0.3 7.6 6.1 7.2 0.3 8 6.5 53 4 60 305 5.7 0.1 6.1 5.4 06/13/2005 16:40:00 7 0.3 7.6 6.5 7.4 0.2 8 6.1 47 3 46 305 5.5 0.1 6.1 5.4 06/13/2005 16:50:00 6.9 0.3 7.6 6.5 7.3 0.2 8 6.5 45 2 45 305 5.5 0.1 6.1 5.4 06/13/2005 17:00:00 6.9 0.3 7.6 6.1 7.2 0.3 7.6 6.5 46 2 45 305 5.5 0 5.9 5.4 06/13/2005 17:10:00 7 0.2 7.6 6.5 7.3 0.2 7.6 6.5 45 2 40 305 5.3 0 5.9 5.2 06/13/2005 17:20:00 6.8 0.2 7.2 6.1 7 0.3 7.6 5.7 45 4 47 305 5.4 0 5.6 5.2 06/13/2005 17:30:00 6.1 0.3 6.8 5.7 6.2 0.3 6.8 5.3 33 3 36 305 5.4 0 5.6 5.2 06/13/2005 17:40:00 6.2 0.2 6.8 5.7 6.4 0.3 7.2 5.7 38 3 41 305 5.3 0 5.6 5.2 06/13/2005 17:50:00 6.3 0.3 7.2 5.3 6.6 0.3 7.2 5.7 37 4 40 305 5.3 0.1 5.9 5.2 06/13/2005 18:00:00 6.4 0.3 6.8 5.7 6.5 0.3 7.2 4.9 33 3 39 305 5.3 0 5.6 4.9 06/13/2005 18:10:00 6.5 0.2 6.8 6.1 6.5 0.3 7.2 5.7 33 3 39 305 5.3 0 5.6 5.2 06/13/2005 18:20:00 6.4 0.2 7.2 6.1 6.5 0.3 7.2 5.7 32 3 34 305 5.2 0.1 5.4 4.9 06/13/2005 18:30:00 6.5 0.2 6.8 5.7 6.6 0.2 7.2 6.1 32 3 38 305 5.4 0 5.6 5.2 06/13/2005 18:40:00 6.7 0.2 7.2 6.1 6.7 0.3 7.2 6.1 30 2 31 305 5.5 0.1 5.6 4.9 06/13/2005 18:50:00 6.7 0.3 7.2 6.1 6.8 0.4 7.6 6.1 33 3 33 305 5.3 0 5.6 4.9 06/13/2005 19:00:00 6.3 0.2 6.8 5.7 6.3 0.2 6.8 5.7 28 3 27 305 5.2 0 5.4 4.9 06/13/2005 19:10:00 6.4 0.2 6.8 6.1 6.7 0.3 7.2 6.1 34 3 30 305 5.2 0 5.4 5.2 06/13/2005 19:20:00 6.6 0.3 7.6 6.1 6.9 0.3 7.6 5.7 38 4 37 305 5.2 0.2 5.6 4.9 06/13/2005 19:30:00 6.4 0.3 7.2 5.3 6.8 0.3 7.6 5.7 38 4 39 305 5.1 0.1 5.4 4.9 06/13/2005 19:40:00 6.2 0.2 6.8 5.7 6.6 0.2 7.2 6.1 41 3 37 305 5.2 0 5.4 4.9 06/13/2005 19:50:00 6.2 0.2 6.8 5.7 6.6 0.2 7.2 6.1 35 4 35 305 5.2 0 5.4 5.2 06/13/2005 20:00:00 6.1 0.2 6.5 5.7 6.3 0.2 6.8 5.7 30 5 40 305 5.1 0 5.4 4.9 06/13/2005 20:10:00 6.2 0.2 6.5 5.7 6.4 0.2 6.8 5.7 30 4 27 305 5.2 0 5.4 4.9 06/13/2005 20:20:00 6.2 0.2 6.5 5.7 6.3 0.2 6.8 5.7 27 2 26 305 5 0 5.2 4.9 06/13/2005 20:30:00 6 0.2 6.5 5.7 6.2 0.2 6.8 5.7 28 4 24 305 5.3 0 5.4 5.2 06/13/2005 20:40:00 5.7 0.2 6.1 5.3 6.1 0.2 6.5 5.7 38 2 37 305 5.3 0 5.4 5.2 06/13/2005 20:50:00 5.8 0.3 6.5 5.3 6 0.2 6.5 5.7 36 3 33 305 5.3 0 5.4 5.2 06/13/2005 21:00:00 5.6 0.3 6.5 4.9 5.8 0.3 6.5 4.9 31 3 32 305 5 0.1 5.4 4.9 06/13/2005 21:10:00 5.8 0.3 6.5 5.3 5.9 0.3 6.5 5.3 35 3 40 305 4.9 0 5.2 4.9 06/13/2005 21:20:00 5.4 0.3 6.1 4.9 5.5 0.3 6.5 4.6 36 3 35 305 5 0 5.2 4.9 06/13/2005 21:30:00 5.6 0.2 6.1 5.3 5.9 0.2 6.5 5.3 40 2 41 305 5.1 0 5.4 4.9 06/13/2005 21:40:00 4.8 1 6.5 1.9 5.2 1 6.5 2.3 41 11 42 305 5.1 0.1 5.4 4.9 06/13/2005 21:50:00 5.2 0.5 6.1 3.8 5.8 0.4 6.8 4.2 43 5 44 305 5 0 5.4 4.9 06/13/2005 22:00:00 5.7 0.3 6.5 4.6 6.1 0.2 6.8 5.7 42 4 36 305 4.8 0 4.9 4.7 06/13/2005 22:10:00 5.9 0.2 6.5 5.3 6.2 0.2 6.5 5.7 36 2 39 305 4.8 0 4.9 4.7 06/13/2005 22:20:00 5.9 0.2 6.5 5.3 6.1 0.3 6.5 5.3 36 3 37 305 4.5 0 4.7 4.4 06/13/2005 22:30:00 6.2 0.3 6.8 5.3 6.6 0.3 7.2 5.7 38 3 33 305 4.5 0 4.7 4.4 06/13/2005 22:40:00 6 0.2 6.5 5.3 6.7 0.2 7.2 6.1 46 3 41 305 4.6 0 4.7 4.4 06/13/2005 22:50:00 4.9 1.3 6.5 2.3 5.5 1.2 7.2 2.3 53 10 47 305 4.4 0 4.7 4.4 06/13/2005 23:00:00 3.1 0.7 4.9 1.5 3.8 0.7 5.7 2.3 58 13 30 305 4.6 0 4.9 4.4 06/13/2005 23:10:00 3.8 0.9 5.7 1.1 4.7 0.9 6.1 2.3 47 9 53 305 4.5 0.1 4.9 4.4 06/13/2005 23:20:00 1.8 1.3 4.9 0.4 2.7 1.3 5.7 0.4 54 30 58 305 4.7 0.4 5.4 4.4 06/13/2005 23:30:00 0.5 0.3 1.9 0.4 1 0.4 1.9 0.4 89 21 60 305 5.6 0 5.9 5.4 06/13/2005 23:40:00 0.7 0.4 1.5 0.4 1.4 0.3 2.3 0.7 186 39 221 305 5.2 0.3 5.9 4.7 06/13/2005 23:50:00 1.2 0.4 1.9 0.4 1.3 0.3 1.9 0.4 234 6 231 305 4.6 0.1 4.9 4.4 06/14/2005 00:00:00 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 234 10 244 305 4.4 0 4.9 4.4 06/14/2005 00:10:00 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 224 2 305 305 4.3 0 4.4 4.2 06/14/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 225 2 305 305 4.2 0 4.4 4.2 06/14/2005 00:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 224 2 305 305 4 0 4.4 3.7 06/14/2005 00:40:00 2.8 1.4 4.9 0.4 3.3 1.2 5.3 0.7 96 82 41 305 3.6 0.2 4.2 3.2 06/14/2005 00:50:00 5.2 0.2 5.7 4.6 5.5 0.2 6.1 4.9 44 2 44 305 3.4 0 3.4 3.2 06/14/2005 01:00:00 5.8 0.3 6.5 5.3 6.1 0.3 6.5 5.3 39 2 38 305 3.3 0 3.4 3.2 06/14/2005 01:10:00 6.1 0.2 6.5 5.7 6.4 0.2 6.8 6.1 40 2 37 305 3.3 0 3.4 3.2 06/14/2005 01:20:00 5.3 1 6.5 2.6 5.3 1.1 6.8 2.3 48 5 43 305 3.4 0 3.7 3.2 06/14/2005 01:30:00 3.1 1.7 5.3 0.4 3.2 1.7 5.3 0.4 182 61 210 305 3.4 0.1 3.7 3.2 06/14/2005 01:40:00 2.6 1.1 4.6 0.4 2.6 0.7 4.6 1.1 198 13 213 305 2.9 0.1 3.2 2.7 06/14/2005 01:50:00 1 0.6 2.3 0.4 1.5 0.5 2.3 0.4 111 49 9 305 2.8 0.1 3.4 2.5 06/14/2005 02:00:00 2.3 1.1 4.2 0.4 2.4 0.9 4.2 1.1 24 6 24 305 3.5 0 3.7 3.2 06/14/2005 02:10:00 4.2 0.3 4.9 3.4 4.4 0.3 5.3 3.8 26 4 26 305 3.2 0 3.7 2.9 06/14/2005 02:20:00 5 0.2 5.7 4.6 5.3 0.2 5.7 4.6 38 3 41 305 2.9 0 3.2 2.9 06/14/2005 02:30:00 4.7 0.3 5.3 3.8 4.9 0.3 5.3 4.2 35 2 33 305 3.2 0 3.7 2.9 06/14/2005 02:40:00 4.1 0.2 4.6 3.8 4.3 0.2 4.9 3.8 33 2 35 305 3.2 0 3.7 2.9 06/14/2005 02:50:00 4.1 0.5 5.3 3 4.4 0.4 5.3 3.4 32 5 37 305 3.2 0 3.7 2.9 06/14/2005 03:00:00 4.5 0.3 5.3 3 4.7 0.3 5.3 3.4 38 2 45 305 3.1 0.1 3.4 2.9 06/14/2005 03:10:00 4.2 0.2 4.9 3.8 4.5 0.2 4.9 3.8 34 2 33 305 2.9 0.1 3.2 2.7 06/14/2005 03:20:00 4.4 0.3 4.9 3.8 4.7 0.3 5.3 4.2 27 2 25 305 2.9 0 3.4 2.7 06/14/2005 03:30:00 4.5 0.4 4.9 3.4 4.6 0.4 5.3 3.4 23 4 25 305 3 0 3.4 2.7 06/14/2005 03:40:00 3.7 0.3 4.6 3 3.9 0.3 4.6 3.4 22 5 29 305 2.7 0 3.4 2.5 06/14/2005 03:50:00 4.8 0.2 5.3 4.2 4.9 0.2 5.3 4.2 31 2 30 305 2.9 0.1 3.4 2.5 06/14/2005 04:00:00 5.3 0.2 5.7 4.9 5.4 0.3 6.1 4.6 28 1 27 305 3.3 0.1 3.7 2.9 06/14/2005 04:10:00 5.3 0.2 5.7 4.9 5.5 0.2 6.1 4.9 26 1 25 305 3.2 0 3.7 2.9 06/14/2005 04:20:00 5.7 0.3 6.5 4.9 5.7 0.2 6.5 5.3 30 2 33 305 3.3 0.1 3.9 3.2 06/14/2005 04:30:00 5.2 0.3 5.7 4.6 5.2 0.3 6.1 4.6 29 3 39 305 3.6 0 4.2 3.2 06/14/2005 04:40:00 5.3 0.4 6.5 4.6 5.4 0.4 6.5 4.6 32 3 45 305 3.7 0 4.2 3.4 06/14/2005 04:50:00 5.8 0.3 6.5 4.9 5.8 0.3 6.8 4.9 30 3 32 305 3.8 0.1 4.4 3.4 06/14/2005 05:00:00 5.5 0.3 6.5 4.6 5.7 0.4 6.8 4.9 29 3 28 305 3.9 0.1 4.4 3.7 06/14/2005 05:10:00 4 0.7 5.7 2.6 4.2 0.7 5.7 2.6 31 3 25 305 3.9 0.1 4.4 3.7 06/14/2005 05:20:00 3.4 0.4 4.2 2.6 3.7 0.4 4.6 2.6 27 4 25 305 4.2 0 4.7 3.9 06/14/2005 05:30:00 3.4 0.3 4.2 2.6 3.6 0.3 4.2 3 25 3 24 305 4.2 0 4.4 4.2 06/14/2005 05:40:00 4.1 0.3 4.9 3.4 4.3 0.3 4.9 3.8 27 3 31 305 4.2 0 4.4 4.2 06/14/2005 05:50:00 4.7 0.2 5.3 3.8 4.9 0.2 5.7 4.2 28 2 33 305 4 0 4.4 3.9 06/14/2005 06:00:00 3.8 0.3 4.6 3 4 0.3 4.9 3.4 23 3 28 305 4.1 0 4.4 3.9 06/14/2005 06:10:00 3.5 0.2 3.8 3 3.7 0.2 4.2 3.4 24 3 19 305 3.9 0 4.2 3.7 06/14/2005 06:20:00 3.7 0.3 4.2 3 3.7 0.3 4.2 3 25 2 24 305 4 0 4.4 3.9 06/14/2005 06:30:00 4.1 0.2 4.6 3.8 4.3 0.2 4.9 3.8 30 2 28 305 4.3 0 4.4 4.2 06/14/2005 06:40:00 4.9 0.3 5.3 4.2 5 0.3 5.7 3.8 28 3 30 305 4.4 0 4.7 4.4 06/14/2005 06:50:00 5.1 0.3 5.7 4.2 5.3 0.3 6.1 4.6 30 3 33 305 4.4 0 4.7 4.4 06/14/2005 07:00:00 5.6 0.4 6.5 4.9 5.8 0.4 6.8 4.9 32 3 29 305 4.5 0 4.7 4.4 06/14/2005 07:10:00 6.2 0.3 7.2 5.3 6.3 0.3 7.2 5.3 34 3 33 305 4.5 0 4.7 4.4 06/14/2005 07:20:00 6.8 0.3 7.6 6.1 6.9 0.4 7.6 5.3 35 4 41 305 4.5 0.1 4.9 4.4 06/14/2005 07:30:00 7.1 0.3 8 6.5 7.2 0.4 8.4 6.1 34 3 38 305 4.4 0 4.7 4.2 06/14/2005 07:40:00 7.4 0.5 8.8 6.1 7.5 0.4 8.4 6.1 39 4 51 305 4.7 0 4.9 4.4 06/14/2005 07:50:00 7.9 0.7 9.5 6.1 7.8 0.7 9.5 6.1 41 6 41 305 4.7 0 4.9 4.7 06/14/2005 08:00:00 8.6 0.5 9.9 7.2 8.7 0.5 10.3 6.8 42 4 41 305 4.8 0 5.4 4.7 06/14/2005 08:10:00 8.7 0.4 9.9 7.2 8.9 0.4 9.9 7.6 41 4 43 305 4.9 0 5.4 4.7 06/14/2005 08:20:00 8.7 0.4 10.3 7.6 8.9 0.5 10.7 7.6 42 4 50 305 4.9 0 5.4 4.7 06/14/2005 08:30:00 8.6 0.4 9.9 7.2 8.8 0.4 10.3 7.2 41 3 50 305 4.9 0.1 5.4 4.9 06/14/2005 08:40:00 8.7 0.4 9.5 7.6 8.9 0.4 9.9 8 40 3 49 305 5 0.1 5.4 4.9 06/14/2005 08:50:00 9.1 0.5 10.3 7.6 9.2 0.5 10.3 7.2 43 3 54 305 5.2 0 5.4 4.9 06/14/2005 09:00:00 9.8 0.3 10.3 8.8 9.8 0.3 10.3 8.8 45 2 41 305 5.3 0 5.6 4.9 06/14/2005 09:10:00 9.9 0.2 10.3 9.1 9.9 0.2 10.3 9.1 48 2 49 305 5.4 0 5.6 5.4 06/14/2005 09:20:00 9.3 0.3 10.3 8.8 9.3 0.3 9.9 8.4 46 2 52 305 5.4 0 5.6 5.4 06/14/2005 09:30:00 8.9 0.3 9.9 7.6 9 0.3 9.9 8 46 3 48 305 5.5 0 5.6 5.4 06/14/2005 09:40:00 8.9 0.3 9.5 7.6 8.9 0.4 9.5 7.2 49 3 50 305 5.5 0 5.6 5.4 06/14/2005 09:50:00 8.6 0.3 9.5 7.2 8.8 0.4 9.9 6.8 45 3 52 305 5.6 0 5.9 5.4 06/14/2005 10:00:00 9.5 0.4 10.3 8.4 9.6 0.4 10.3 8.4 46 2 43 305 5.7 0 5.9 5.6 06/14/2005 10:10:00 10.2 0.3 11.1 9.5 10.2 0.3 11.1 9.1 49 2 48 305 5.7 0 5.9 5.6 06/14/2005 10:20:00 10.6 0.4 11.5 9.9 10.6 0.4 11.5 9.9 50 2 54 305 5.8 0 5.9 5.6 06/14/2005 10:30:00 10.3 0.7 11.8 8.4 10.2 0.7 11.8 8.4 53 3 59 305 5.9 0 6.1 5.6 06/14/2005 10:40:00 9.1 0.6 10.3 7.2 9 0.6 10.3 6.8 53 4 58 305 6.1 0.1 6.4 5.9 06/14/2005 10:50:00 9.2 0.5 10.3 8.4 9.1 0.6 10.7 7.2 51 3 54 305 6.2 0 6.4 5.9 06/14/2005 11:00:00 9.5 0.4 10.3 8.4 9.5 0.5 10.3 8 48 3 46 305 6.1 0.1 6.4 5.9 06/14/2005 11:10:00 9.7 0.3 10.3 8.8 9.7 0.3 10.3 8.8 49 2 47 305 6.1 0 6.4 5.9 06/14/2005 11:20:00 9.4 0.3 10.3 8.4 9.5 0.3 9.9 8.8 46 3 48 305 6.1 0 6.4 5.9 06/14/2005 11:30:00 9.1 0.4 9.9 8 9.3 0.4 10.3 7.6 45 3 49 305 6.2 0.1 6.4 5.9 06/14/2005 11:40:00 9.1 0.3 9.9 8 9.2 0.4 10.3 7.6 46 3 48 305 6.3 0 6.4 6.1 06/14/2005 11:50:00 9.3 0.3 10.3 8.4 9.3 0.3 10.3 8 48 2 50 305 6 0 6.4 5.9 06/14/2005 12:00:00 9.6 0.3 10.7 8.8 9.6 0.3 10.7 8.4 50 2 51 305 6.5 0.1 6.7 6.1 06/14/2005 12:10:00 9.4 0.5 10.7 8.4 9.3 0.5 10.7 7.6 50 3 53 305 6.7 0 6.9 6.4 06/14/2005 12:20:00 9 0.4 9.9 7.2 9 0.5 9.9 6.8 52 3 54 305 6.8 0 7.2 6.7 06/14/2005 12:30:00 8.3 0.5 9.9 6.8 8.3 0.5 9.9 7.2 51 4 53 305 6.8 0.2 7.2 6.4 06/14/2005 12:40:00 8.3 0.4 9.9 7.2 8.3 0.4 9.1 7.2 49 4 56 305 6.8 0 7.2 6.4 06/14/2005 12:50:00 7.8 0.5 9.1 6.5 7.8 0.5 9.1 6.1 46 4 50 305 6.8 0 7.2 6.4 06/14/2005 13:00:00 7.3 0.4 8.4 6.1 7.1 0.6 8.4 5.3 45 4 46 305 6.8 0 7.2 6.4 06/14/2005 13:10:00 7.7 0.5 8.8 6.5 7.6 0.5 8.8 5.7 44 3 49 305 7.1 0.1 7.4 6.9 06/14/2005 13:20:00 7.8 0.4 8.8 6.8 7.8 0.4 9.1 6.1 39 4 33 305 6.9 0 7.2 6.7 06/14/2005 13:30:00 8.6 0.3 9.5 7.6 8.5 0.4 9.1 6.5 40 3 39 305 7 0 7.4 6.9 06/14/2005 13:40:00 8.1 0.4 9.1 7.2 8.1 0.4 9.1 6.8 41 4 42 305 7.1 0.1 7.4 6.9 06/14/2005 13:50:00 6.9 0.8 8.8 4.6 6.9 0.9 8.8 3.8 44 5 54 305 6.8 0 7.2 6.7 06/14/2005 14:00:00 5.5 0.5 6.8 3.8 5.5 0.6 6.8 3.8 35 6 32 305 6.7 0 7.2 6.4 06/14/2005 14:10:00 5.6 0.6 6.5 3.8 5.7 0.6 6.8 3.8 36 4 37 305 6.8 0 6.9 6.4 06/14/2005 14:20:00 6.5 0.3 7.6 5.3 6.5 0.4 7.2 5.3 38 4 40 305 6.8 0 7.2 6.7 06/14/2005 14:30:00 6.6 0.3 7.2 5.7 6.6 0.4 7.6 4.6 35 4 40 305 6.7 0 7.4 6.4 06/14/2005 14:40:00 6.7 0.3 7.6 5.7 6.8 0.4 8 5.3 34 3 40 305 6.6 0 6.7 6.4 06/14/2005 14:50:00 6.2 0.4 7.2 5.3 6.2 0.4 7.2 4.9 37 4 42 305 6.8 0 7.2 6.4 06/14/2005 15:00:00 5.3 0.4 6.5 4.2 5.4 0.5 6.5 4.2 35 4 41 305 6.9 0 7.4 6.7 06/14/2005 15:10:00 4.9 0.3 5.7 3.8 5 0.4 5.7 3.8 33 4 35 305 6.8 0 7.2 6.4 06/14/2005 15:20:00 5.6 0.3 6.1 4.6 5.6 0.4 6.5 4.2 33 3 36 305 7.2 0.1 7.9 6.9 06/14/2005 15:30:00 6.2 0.3 7.2 5.3 6.3 0.4 6.8 4.9 35 4 39 305 6.8 0.1 7.4 6.4 06/14/2005 15:40:00 6.3 0.3 6.8 5.3 6.3 0.3 6.8 5.3 32 3 35 305 6.7 0.1 7.2 6.4 06/14/2005 15:50:00 5.5 0.4 6.5 3.8 5.6 0.5 6.5 3.8 30 3 31 305 6.5 0 7.2 6.4 06/14/2005 16:00:00 4.4 0.5 5.3 3 4.3 0.5 6.1 2.6 30 5 34 305 6.4 0 6.9 6.1 06/14/2005 16:10:00 4.3 0.3 4.9 3.4 4.4 0.3 5.3 3.4 30 5 27 305 6.4 0 6.7 6.1 06/14/2005 16:20:00 4.8 0.3 5.3 3.8 4.9 0.3 5.7 3.8 27 3 25 305 6.5 0 6.7 6.1 06/14/2005 16:30:00 5.2 0.3 6.1 4.6 5.4 0.4 6.1 4.2 24 3 29 305 6.6 0 6.9 6.4 06/14/2005 16:40:00 5.3 0.3 6.1 4.6 5.4 0.3 6.1 4.6 24 3 21 305 6.8 0.1 7.4 6.4 06/14/2005 16:50:00 5.7 0.3 6.5 4.9 5.8 0.3 6.5 4.9 25 3 26 305 7 0.1 7.4 6.9 06/14/2005 17:00:00 5.9 0.3 6.5 4.9 6 0.3 6.8 4.9 24 3 23 305 7 0.1 7.4 6.9 06/14/2005 17:10:00 6.2 0.3 6.8 4.6 6.3 0.4 7.2 4.9 27 3 25 305 7.2 0 7.4 6.9 06/14/2005 17:20:00 6.2 0.3 6.8 5.3 6.3 0.3 7.2 5.3 30 4 25 305 7 0 7.4 6.9 06/14/2005 17:30:00 6.4 0.2 6.8 5.7 6.4 0.3 7.2 4.9 29 3 26 305 7.3 0 7.4 7.2 06/14/2005 17:40:00 6.3 0.2 6.8 5.7 6.3 0.3 6.8 5.3 29 3 36 305 7.2 0.1 7.4 7.2 06/14/2005 17:50:00 6.4 0.3 7.2 5.7 6.5 0.4 7.2 4.9 28 3 33 305 7.2 0.1 7.7 7.2 06/14/2005 18:00:00 6.5 0.3 7.2 5.7 6.5 0.3 7.2 5.7 28 3 22 305 7.3 0.1 7.7 7.2 06/14/2005 18:10:00 6.6 0.3 7.2 5.7 6.6 0.3 7.6 5.7 30 3 31 305 7.3 0 7.7 7.2 06/14/2005 18:20:00 6.4 0.2 6.8 5.7 6.4 0.3 7.2 4.9 28 2 27 305 7.2 0 7.4 7.2 06/14/2005 18:30:00 6.5 0.3 6.8 5.7 6.5 0.3 7.2 5.7 28 2 29 305 7.2 0 7.4 7.2 06/14/2005 18:40:00 6.6 0.2 7.2 5.7 6.7 0.3 7.2 5.7 28 3 36 305 7.1 0 7.4 6.9 06/14/2005 18:50:00 6.5 0.3 7.2 5.7 6.6 0.3 7.2 5.7 29 3 31 305 7 0.2 7.7 6.7 06/14/2005 19:00:00 6.3 0.3 6.8 5.3 6.3 0.3 6.8 5.3 29 3 27 305 7.1 0 7.4 6.9 06/14/2005 19:10:00 6.3 0.3 6.8 5.7 6.4 0.3 6.8 5.3 27 3 27 305 7.2 0 7.4 7.2 06/14/2005 19:20:00 6.4 0.3 6.8 5.3 6.4 0.3 7.2 5.7 27 3 29 305 7.1 0 7.4 7.2 06/14/2005 19:30:00 6.3 0.3 7.2 5.7 6.4 0.3 7.2 5.7 28 3 27 305 7.2 0 7.4 6.9 06/14/2005 19:40:00 6.1 0.3 6.8 5.3 6.1 0.3 6.8 5.3 25 3 30 305 7.2 0 7.4 6.9 06/14/2005 19:50:00 5.7 0.2 6.1 4.9 5.8 0.3 6.5 5.3 20 2 27 305 7 0 7.2 6.9 06/14/2005 20:00:00 5.7 0.2 6.1 5.3 5.6 0.2 6.1 5.3 19 2 22 305 6.8 0 7.2 6.7 06/14/2005 20:10:00 5.7 0.3 6.1 4.9 5.6 0.3 6.1 4.9 20 2 20 305 6.7 0 6.9 6.4 06/14/2005 20:20:00 5.6 0.3 6.1 4.9 5.6 0.3 6.1 4.9 20 2 16 305 6.7 0 6.9 6.4 06/14/2005 20:30:00 5.3 0.3 6.1 4.6 5.4 0.3 6.1 4.6 22 3 21 305 6.8 0 6.9 6.4 06/14/2005 20:40:00 4.8 0.3 5.7 4.2 4.8 0.3 5.7 3.8 22 3 21 305 6.8 0 7.2 6.7 06/14/2005 20:50:00 5.1 0.3 5.7 4.2 5.1 0.3 5.7 4.6 21 2 21 305 7 0 7.2 6.9 06/14/2005 21:00:00 5 0.2 5.7 4.6 5 0.3 5.7 4.2 22 3 21 305 6.9 0 7.2 6.9 06/14/2005 21:10:00 4.9 0.3 5.7 4.2 5 0.3 5.7 4.2 26 3 30 305 6.8 0 7.2 6.7 06/14/2005 21:20:00 5.5 0.3 6.5 4.6 5.6 0.3 6.1 4.6 31 3 28 305 7 0 7.2 6.9 06/14/2005 21:30:00 6.1 0.4 6.8 5.3 6.2 0.4 7.2 5.3 36 3 36 305 7.1 0 7.4 7.2 06/14/2005 21:40:00 6.5 0.5 7.6 5.3 6.6 0.5 7.6 5.7 35 3 38 305 7.4 0 7.7 7.4 06/14/2005 21:50:00 6.9 0.3 7.6 6.1 6.9 0.3 7.6 6.1 38 3 41 305 7.3 0 7.7 7.2 06/14/2005 22:00:00 7.3 0.4 8 6.5 7.4 0.3 8.4 6.5 42 3 43 305 7.5 0 7.7 7.4 06/14/2005 22:10:00 7.3 0.4 8.4 6.5 7.4 0.3 8.4 6.5 43 3 44 305 7.5 0 7.7 7.4 06/14/2005 22:20:00 7.5 0.5 8.8 6.1 7.6 0.4 8.4 6.5 46 3 55 305 7.2 0 7.4 7.2 06/14/2005 22:30:00 6.9 0.3 8 6.1 7 0.3 7.6 6.1 38 4 42 305 6.8 0.1 7.2 6.7 06/14/2005 22:40:00 6.6 0.3 7.6 5.7 6.6 0.3 7.6 5.7 34 3 38 305 6.6 0 6.9 6.4 06/14/2005 22:50:00 6.6 0.3 7.2 5.7 6.7 0.3 7.6 5.7 35 3 32 305 6.6 0 6.9 6.4 06/14/2005 23:00:00 6.7 0.3 7.6 5.7 6.8 0.3 7.6 6.1 37 3 35 305 6.4 0 6.4 6.1 06/14/2005 23:10:00 6.7 0.3 7.6 5.7 6.8 0.3 7.6 6.1 37 3 48 305 6.4 0 6.7 6.1 06/14/2005 23:20:00 6.3 0.3 7.2 5.3 6.4 0.3 6.8 5.3 36 3 40 305 6.1 0.1 6.4 5.9 06/14/2005 23:30:00 5.8 0.3 6.5 4.9 5.8 0.3 6.5 4.6 33 3 29 305 6 0.1 6.4 5.9 06/14/2005 23:40:00 5.7 0.4 6.5 4.6 5.7 0.3 6.5 4.9 31 3 32 305 5.9 0 6.4 5.6 06/14/2005 23:50:00 6 0.4 6.8 5.3 6.1 0.4 6.8 5.3 33 3 40 305 5.9 0 5.9 5.6 06/15/2005 00:00:00 6.6 0.5 7.6 5.3 6.6 0.5 7.6 5.7 38 3 42 305 6 0.1 6.4 5.9 06/15/2005 00:10:00 6.6 0.3 7.2 6.1 6.6 0.3 7.2 6.1 39 3 37 305 6.5 0 6.4 6.1 06/15/2005 00:20:00 6.1 0.3 6.8 5.3 6.2 0.3 6.8 5.3 38 3 38 305 6.2 0 6.4 6.1 06/15/2005 00:30:00 6 0.3 6.8 4.9 6.1 0.3 7.2 5.3 38 3 41 305 6.1 0 6.4 5.9 06/15/2005 00:40:00 5.3 0.3 6.1 4.6 5.5 0.3 6.5 4.9 37 4 38 305 6.3 0 6.4 6.1 06/15/2005 00:50:00 4.8 0.3 5.7 3.8 5 0.2 5.7 4.6 38 4 42 305 6.4 0 6.4 6.1 06/15/2005 01:00:00 4.7 0.3 5.3 3.8 4.9 0.3 5.7 3.8 35 3 33 305 6.3 0 6.4 6.1 06/15/2005 01:10:00 5.6 0.4 6.8 4.6 5.7 0.4 7.2 4.9 39 4 36 305 6.5 0.1 6.9 6.1 06/15/2005 01:20:00 6.4 0.4 7.2 5.3 6.4 0.4 7.6 5.7 41 4 36 305 6.7 0 6.9 6.4 06/15/2005 01:30:00 6.6 0.4 8.4 5.7 6.6 0.3 7.6 5.7 45 4 48 305 6.9 0 7.2 6.7 06/15/2005 01:40:00 6.9 0.6 9.1 5.7 6.8 0.5 8.4 5.3 43 4 48 305 7.4 0.1 7.7 7.2 06/15/2005 01:50:00 6.2 0.4 7.2 4.9 6.3 0.4 7.6 4.9 41 5 43 305 7.4 0 7.7 7.2 06/15/2005 02:00:00 6.5 0.5 8 5.3 6.6 0.4 8 5.7 38 4 38 305 7 0 7.4 6.9 06/15/2005 02:10:00 6.8 0.3 7.6 6.1 7 0.3 7.6 6.1 39 3 39 305 6.7 0.1 6.9 6.4 06/15/2005 02:20:00 6.8 0.3 7.6 6.1 6.9 0.3 8 6.1 42 2 42 305 6.6 0 6.9 6.4 06/15/2005 02:30:00 6.9 0.3 7.6 6.1 7.1 0.3 7.6 6.5 42 3 43 305 6.5 0 6.7 6.4 06/15/2005 02:40:00 7.1 0.2 7.6 6.5 7.2 0.3 7.6 6.5 43 3 45 305 6.3 0 6.4 5.9 06/15/2005 02:50:00 7.2 0.3 8 6.5 7.3 0.3 8 6.5 43 4 46 305 6.3 0 6.4 6.1 06/15/2005 03:00:00 7.1 0.3 8 6.5 7.2 0.3 8 6.5 42 3 40 305 6.2 0 6.4 6.1 06/15/2005 03:10:00 6.6 0.4 8.4 5.7 6.7 0.3 7.6 5.7 40 3 37 305 6.2 0 6.4 6.1 06/15/2005 03:20:00 5.7 0.4 6.8 4.9 5.8 0.4 6.8 4.9 40 3 42 305 6.1 0 6.4 5.9 06/15/2005 03:30:00 6.2 0.5 7.6 5.3 6.3 0.6 7.6 5.3 38 3 39 305 6.3 0 6.7 5.9 06/15/2005 03:40:00 5.8 0.4 6.8 4.9 5.9 0.3 6.8 5.3 35 3 32 305 6.3 0.1 6.7 5.9 06/15/2005 03:50:00 6.1 0.4 7.2 4.9 6.3 0.4 7.2 5.3 41 2 47 305 6.3 0.2 6.7 5.9 06/15/2005 04:00:00 6.1 0.3 6.8 5.3 6.3 0.3 7.2 5.3 41 4 45 305 6.5 0 6.9 6.1 06/15/2005 04:10:00 6.7 0.4 7.6 5.3 6.8 0.4 8 5.7 43 3 38 305 6.4 0 6.7 6.1 06/15/2005 04:20:00 6.7 0.4 7.6 5.7 6.8 0.3 7.6 6.1 46 3 46 305 6.4 0 6.7 6.1 06/15/2005 04:30:00 6.4 0.3 7.2 5.7 6.4 0.4 7.6 5.7 47 5 54 305 6.3 0.1 6.7 5.9 06/15/2005 04:40:00 6 0.3 7.2 4.9 6.1 0.3 6.8 5.3 40 5 50 305 6 0.1 6.4 5.9 06/15/2005 04:50:00 6.6 0.3 7.2 5.7 6.7 0.3 7.6 5.7 40 4 46 305 6 0 6.1 5.9 06/15/2005 05:00:00 6.1 0.5 7.2 5.3 6.3 0.5 7.2 5.3 38 4 37 305 6 0 6.1 5.9 06/15/2005 05:10:00 5.9 0.4 6.8 4.9 6 0.4 6.8 4.9 46 5 47 305 6 0 6.1 5.9 06/15/2005 05:20:00 6.9 0.5 8 5.7 6.9 0.5 8.4 5.3 43 4 40 305 6.1 0.1 6.4 5.9 06/15/2005 05:30:00 6.7 0.4 7.6 5.7 6.8 0.4 7.6 6.1 42 4 44 305 6 0 6.1 5.9 06/15/2005 05:40:00 6.4 0.4 7.6 5.3 6.5 0.4 7.6 5.7 41 4 46 305 6.3 0.2 6.7 5.9 06/15/2005 05:50:00 6.2 0.4 7.6 5.3 6.3 0.4 8 5.3 40 4 39 305 6.3 0.1 6.4 5.9 06/15/2005 06:00:00 6.5 0.4 7.6 5.7 6.6 0.4 7.6 5.7 39 3 37 305 6.1 0 6.4 5.9 06/15/2005 06:10:00 6.4 0.3 7.6 5.7 6.5 0.3 7.6 5.7 40 4 40 305 6.4 0 6.4 6.1 06/15/2005 06:20:00 6.3 0.3 7.2 5.3 6.4 0.3 7.2 5.7 36 3 41 305 6.5 0 6.7 6.4 06/15/2005 06:30:00 6.1 0.4 6.8 5.3 6.2 0.4 6.8 5.3 39 4 32 305 6.5 0 6.9 6.1 06/15/2005 06:40:00 6.5 0.3 7.2 5.7 6.7 0.3 7.6 6.1 37 4 33 305 6.5 0 6.9 6.1 06/15/2005 06:50:00 6 0.4 6.8 5.3 6.2 0.4 7.2 4.9 43 5 40 305 6.4 0 6.4 6.1 06/15/2005 07:00:00 6.4 0.5 7.6 5.3 6.5 0.5 8 5.3 38 5 31 305 6.5 0 6.7 6.1 06/15/2005 07:10:00 6.7 0.3 7.6 5.7 6.9 0.4 8 5.3 39 4 30 305 6.5 0 6.9 6.4 06/15/2005 07:20:00 6.8 0.4 8 5.3 6.9 0.4 8 5.7 40 4 37 305 6.6 0 6.9 6.4 06/15/2005 07:30:00 7.1 0.5 8.4 6.1 7.2 0.5 8.4 6.1 42 4 36 305 6.9 0 7.2 6.7 06/15/2005 07:40:00 7.4 0.5 9.1 6.1 7.4 0.5 8.8 6.1 43 5 45 305 6.7 0 7.2 6.4 06/15/2005 07:50:00 7.3 0.6 9.5 5.7 7.2 0.6 9.1 5.7 44 6 42 305 7 0 7.2 6.9 06/15/2005 08:00:00 7.7 0.6 9.5 6.1 7.7 0.5 9.5 6.5 41 5 40 305 7.2 0 7.4 6.9 06/15/2005 08:10:00 7.4 0.6 9.1 6.1 7.4 0.6 9.1 5.7 47 5 41 305 7.2 0 7.4 7.2 06/15/2005 08:20:00 8.2 0.8 10.7 6.1 8.2 0.7 9.9 6.5 43 5 52 305 7.2 0 7.4 7.2 06/15/2005 08:30:00 8 0.5 9.5 6.5 8 0.5 9.5 6.8 44 5 43 305 7.2 0 7.4 7.2 06/15/2005 08:40:00 8.4 0.6 9.9 6.5 8.3 0.6 9.9 6.5 41 6 43 305 7.3 0 7.7 7.2 06/15/2005 08:50:00 8.5 0.7 10.3 6.8 8.4 0.7 10.7 6.8 41 6 38 305 7.5 0.1 7.9 7.2 06/15/2005 09:00:00 8.8 0.6 10.7 6.8 8.8 0.6 10.7 6.8 44 5 44 305 7.7 0 7.9 7.7 06/15/2005 09:10:00 9.1 0.8 11.1 7.2 9 0.7 11.1 7.2 45 5 46 305 7.8 0 7.9 7.7 06/15/2005 09:20:00 8.6 0.6 10.3 7.2 8.5 0.7 10.3 6.8 46 6 44 305 7.7 0 7.9 7.7 06/15/2005 09:30:00 8.3 0.6 10.3 6.8 8.3 0.7 9.9 6.5 45 6 50 305 7.7 0 7.9 7.4 06/15/2005 09:40:00 8.2 0.6 9.5 6.5 8.3 0.6 9.9 6.5 47 6 51 305 7.7 0.1 8.2 7.7 06/15/2005 09:50:00 8.9 0.5 10.7 7.6 8.8 0.5 10.3 7.2 51 5 43 305 7.8 0 7.9 7.7 06/15/2005 10:00:00 9.2 0.5 10.3 8 9.2 0.5 10.3 8 51 5 60 305 7.7 0 7.9 7.4 06/15/2005 10:10:00 9.5 0.5 11.1 8.4 9.5 0.5 11.1 8 51 5 48 305 7.6 0 7.9 7.4 06/15/2005 10:20:00 9.5 0.5 11.1 8 9.5 0.6 11.1 7.6 51 5 49 305 7.5 0 7.7 7.4 06/15/2005 10:30:00 9.7 0.5 11.1 8.4 9.7 0.4 11.1 8.8 52 4 45 305 7.6 0 7.7 7.4 06/15/2005 10:40:00 10 0.4 11.1 8.8 9.9 0.5 11.5 8.4 52 4 56 305 7.5 0 7.7 7.4 06/15/2005 10:50:00 10 0.5 11.5 8.8 9.9 0.5 11.1 8.4 53 3 53 305 7.5 0 7.7 7.4 06/15/2005 11:00:00 9.7 0.4 10.7 8.4 9.6 0.4 10.7 7.6 53 3 60 305 7.5 0.1 7.9 7.2 06/15/2005 11:10:00 9.6 0.4 11.1 8.4 9.5 0.5 11.1 8 51 5 46 305 7.3 0 7.7 7.2 06/15/2005 11:20:00 9.8 0.5 11.1 8.8 9.7 0.5 11.1 8 52 5 48 305 7.2 0 7.4 7.2 06/15/2005 11:30:00 10.3 0.5 11.8 9.1 10.3 0.5 11.8 8.8 53 4 51 305 7.4 0 7.7 7.2 06/15/2005 11:40:00 10.6 0.4 11.5 9.1 10.6 0.4 11.8 9.1 54 3 53 305 7.3 0.1 7.7 7.2 06/15/2005 11:50:00 10.8 0.4 11.8 9.5 10.7 0.4 11.5 9.9 55 3 56 305 7.1 0 7.4 6.9 06/15/2005 12:00:00 11.2 0.4 12.6 10.3 11.1 0.4 12.2 10.3 54 2 54 305 7.2 0.1 7.4 7.2 06/15/2005 12:10:00 11 0.9 13.3 8.8 10.7 0.9 13 8.4 65 7 74 305 7.9 0.5 9.2 7.4 06/15/2005 12:20:00 10.5 0.9 13.3 8.4 10.1 0.8 12.6 8.4 66 7 77 305 7.7 0.1 8.2 7.7 06/15/2005 12:30:00 10.1 0.8 11.8 8 9.7 0.8 11.8 7.6 71 7 67 305 9.4 0.9 10.8 7.9 06/15/2005 12:40:00 10.7 0.9 13 8.4 10.5 0.9 13 8.4 73 6 66 305 11.2 0.3 11.8 10.5 06/15/2005 12:50:00 11.6 1 13.7 8.8 11.2 1.1 14.1 8.4 77 7 78 305 11.2 0.1 11.6 10.8 06/15/2005 13:00:00 11.2 1 14.5 8.4 10.8 1 13.7 8 76 7 89 305 11.3 0 11.3 11 06/15/2005 13:10:00 11 1 13.3 8.4 10.6 1 13.3 7.6 78 7 79 305 11.8 0.2 12.4 11.3 06/15/2005 13:20:00 10.8 0.9 12.6 8 10.4 0.9 12.6 6.8 71 9 81 305 11.4 0.6 12.1 9.7 06/15/2005 13:30:00 10 1.1 12.6 7.2 9.6 1.2 12.2 6.8 64 10 71 305 9.9 0.6 10.8 9.2 06/15/2005 13:40:00 9 1 11.1 6.5 8.9 1 11.1 6.5 61 9 55 305 10 0.4 10.8 9.5 06/15/2005 13:50:00 7.4 1 9.9 4.6 7.2 1 9.5 4.9 46 9 71 305 8.8 0.4 10 8.2 06/15/2005 14:00:00 5.5 1 8 3 5.5 1 8.4 3 20 13 35 305 8.1 0.1 8.9 7.9 06/15/2005 14:10:00 4.5 0.5 5.7 3 4.6 0.5 5.7 3 357 11 348 305 8.2 0.1 8.9 7.9 06/15/2005 14:20:00 5.2 0.5 6.5 3.8 5.2 0.5 6.8 3.8 14 8 26 305 8.2 0.1 8.9 7.9 06/15/2005 14:30:00 5 0.7 6.5 3.4 5.1 0.7 6.8 3.4 10 9 14 305 8.1 0 8.4 7.9 06/15/2005 14:40:00 4.4 0.4 5.7 2.6 4.5 0.5 5.7 2.6 353 9 352 305 7.9 0 8.4 7.4 06/15/2005 14:50:00 4.2 0.4 5.3 3 4.3 0.4 5.7 3.4 359 7 0 305 7.3 0.1 7.9 7.2 06/15/2005 15:00:00 4.7 0.4 6.1 3.4 4.9 0.4 6.1 3.4 3 6 348 305 7.3 0.1 7.7 7.2 06/15/2005 15:10:00 5 0.4 6.1 4.2 5.1 0.4 6.1 4.2 3 6 8 305 7.6 0 8.2 7.4 06/15/2005 15:20:00 5 0.4 6.1 4.2 5.1 0.4 6.1 3.8 13 4 16 305 7.5 0 7.9 7.4 06/15/2005 15:30:00 5 0.5 6.1 3.8 5.1 0.5 6.1 3.8 7 5 17 305 7.6 0 8.2 7.4 06/15/2005 15:40:00 4.5 0.8 6.1 1.9 5 0.6 6.5 3.4 14 6 0 305 7.7 0 8.2 7.4 06/15/2005 15:50:00 4 0.8 5.7 1.9 4.6 0.7 6.1 2.6 27 8 29 305 8 0.2 8.9 7.7 06/15/2005 16:00:00 3.2 1.1 6.5 0.4 3.8 1.1 8 1.1 22 39 357 305 9 0.3 9.5 8.4 06/15/2005 16:10:00 2.3 1.2 5.3 0.4 3.3 1.1 6.1 0.7 79 53 50 305 9 0.2 9.7 8.4 06/15/2005 16:20:00 1.6 0.8 4.2 0.4 2.2 0.7 3.8 0.4 65 17 65 305 10.1 0.4 10.8 9.5 06/15/2005 16:30:00 2.6 1.3 5.7 0.4 3.3 1.5 6.1 0.4 50 14 46 305 9.9 1 11.3 8.4 06/15/2005 16:40:00 2.9 0.6 4.6 1.1 4.2 0.6 5.7 3 50 8 56 305 8.2 0.1 8.7 7.9 06/15/2005 16:50:00 3.1 0.6 4.9 0.7 4.3 0.6 5.3 2.6 44 9 46 305 7.9 0.1 8.2 7.7 06/15/2005 17:00:00 1.3 0.8 3.4 0.4 2.3 1 5.3 0.4 76 41 39 305 8.9 0.7 10.5 7.9 06/15/2005 17:10:00 4.6 1.2 6.1 0.4 4.5 1 6.1 1.1 213 20 236 305 8.9 1.2 10.8 7.2 06/15/2005 17:20:00 5.2 0.5 6.5 3.4 5.2 0.6 6.5 3.8 211 6 217 305 7 0 7.4 6.9 06/15/2005 17:30:00 5.1 0.5 6.5 3.4 4.9 0.5 6.1 3.4 215 7 205 305 7.1 0 7.7 6.9 06/15/2005 17:40:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 3.8 208 6 196 305 7.2 0.1 7.7 7.2 06/15/2005 17:50:00 5.7 0.5 6.8 4.2 5.6 0.5 6.8 3.8 206 6 208 305 6.8 0.2 7.7 6.7 06/15/2005 18:00:00 5.4 0.5 6.8 4.2 5.3 0.6 6.5 3.8 202 6 209 305 6.6 0 6.9 6.4 06/15/2005 18:10:00 5.3 0.4 6.5 4.2 5.3 0.5 6.5 3.8 201 7 198 305 6.4 0 7.2 6.1 06/15/2005 18:20:00 6.1 0.7 7.6 3.8 6.1 0.7 8 3.8 197 8 198 305 6.1 0.1 6.7 5.9 06/15/2005 18:30:00 7.1 0.6 8.8 5.3 7 0.7 8.8 5.3 198 7 206 305 5.9 0 6.7 5.6 06/15/2005 18:40:00 7.4 0.6 9.1 5.7 7.4 0.6 8.8 5.7 198 5 208 305 5.6 0 5.9 5.6 06/15/2005 18:50:00 7 0.6 8.8 5.7 6.9 0.6 8.8 5.3 197 5 198 305 5.5 0 5.9 5.4 06/15/2005 19:00:00 7 0.5 8.4 5.7 6.9 0.5 8.8 5.3 201 5 195 305 5 0.1 5.4 4.7 06/15/2005 19:10:00 7 0.6 8.8 5.3 6.9 0.7 8.4 4.9 198 6 208 305 4.6 0 4.9 4.4 06/15/2005 19:20:00 7.2 0.6 8.8 4.9 7 0.7 8.4 4.6 205 5 198 305 4.2 0 4.7 4.2 06/15/2005 19:30:00 7.8 0.8 9.1 5.7 7.7 0.9 9.1 4.9 202 5 200 305 4 0.1 4.4 3.7 06/15/2005 19:40:00 7.6 0.4 8.8 6.5 7.4 0.4 8.4 6.5 203 4 205 305 3.7 0 3.7 3.7 06/15/2005 19:50:00 7.3 0.7 8.8 5.3 6.8 0.8 8.4 3.8 211 6 214 305 3.8 0 3.9 3.7 06/15/2005 20:00:00 8 0.6 9.1 6.1 7.6 0.7 8.8 5.3 210 4 214 305 3.8 0 3.9 3.7 06/15/2005 20:10:00 8.4 0.8 9.9 5.7 8 0.8 9.9 5.7 210 6 213 305 3.7 0 3.9 3.7 06/15/2005 20:20:00 8.9 0.8 10.7 6.5 8.5 1 10.7 5.7 212 5 209 305 3.9 0 4.2 3.7 06/15/2005 20:30:00 8.9 0.8 10.7 6.1 8.5 1 10.7 6.1 216 6 221 305 4 0 4.2 3.7 06/15/2005 20:40:00 8.6 0.7 10.3 6.8 8.1 0.8 9.5 6.1 214 5 203 305 4.1 0 4.4 3.9 06/15/2005 20:50:00 8.4 0.7 9.9 6.1 8.1 0.8 9.9 5.7 215 5 218 305 4.2 0 4.4 4.2 06/15/2005 21:00:00 9.5 0.8 11.5 6.8 9.1 0.9 11.1 6.1 219 5 219 305 4.2 0 4.4 4.2 06/15/2005 21:10:00 9.2 0.8 10.7 6.1 8.7 1 10.7 5.7 213 5 210 305 4.2 0 4.4 4.2 06/15/2005 21:20:00 8.3 0.9 10.7 6.1 7.9 0.9 10.3 5.7 214 7 215 305 4.2 0 4.4 4.2 06/15/2005 21:30:00 9.2 0.5 10.7 6.5 8.8 0.7 10.3 6.5 216 5 221 305 4.2 0 4.4 4.2 06/15/2005 21:40:00 9.4 0.7 10.7 6.8 9.2 0.7 10.7 6.8 214 3 208 305 4.4 0 4.4 4.2 06/15/2005 21:50:00 9.4 0.9 11.5 7.2 9.1 1 11.1 6.5 215 5 211 305 4.3 0 4.4 4.2 06/15/2005 22:00:00 9.6 0.8 11.8 7.6 9.2 1 11.5 7.2 217 5 213 305 4.4 0 4.7 4.2 06/15/2005 22:10:00 10 0.6 11.8 8.4 9.6 0.8 11.5 7.2 216 5 217 305 4.4 0 4.7 4.4 06/15/2005 22:20:00 9.6 0.6 11.5 7.6 9.3 0.8 11.1 6.5 215 6 214 305 4.3 0 4.7 4.2 06/15/2005 22:30:00 8.6 0.7 10.3 6.5 8.2 0.7 9.9 6.1 219 6 225 305 4.5 0 4.7 4.4 06/15/2005 22:40:00 9.5 0.5 10.7 7.6 9.2 0.7 10.7 6.8 218 5 217 305 4.4 0 4.7 4.4 06/15/2005 22:50:00 8.9 0.8 11.1 6.5 8.6 0.9 10.7 6.5 220 5 218 305 4.5 0 4.7 4.4 06/15/2005 23:00:00 8.6 0.8 9.9 5.7 8.2 1 10.3 5.3 219 6 218 305 4.5 0.1 4.7 4.4 06/15/2005 23:10:00 8.7 0.5 9.9 7.2 8.3 0.7 10.3 6.5 217 5 213 305 4.4 0 4.7 4.4 06/15/2005 23:20:00 8.5 0.6 9.9 6.8 8.2 0.7 9.9 5.7 220 6 224 305 4.5 0 4.7 4.4 06/15/2005 23:30:00 7.9 0.6 9.5 6.1 7.5 0.7 9.5 5.7 222 5 216 305 4.5 0 4.9 4.4 06/15/2005 23:40:00 7.8 0.5 8.8 5.7 7.4 0.6 8.8 5.7 224 5 221 305 4.7 0 4.9 4.7 06/15/2005 23:50:00 7.7 0.6 9.5 5.7 7.3 0.7 9.1 5.7 231 5 219 305 4.8 0 4.9 4.7 06/16/2005 00:00:00 6.7 0.7 8.4 4.6 6.3 0.7 8.4 4.6 226 8 220 305 4.8 0 5.4 4.7 06/16/2005 00:10:00 6.5 0.7 8.4 4.9 6.3 0.8 8.4 4.6 223 5 235 305 4.7 0 4.9 4.4 06/16/2005 00:20:00 5.7 0.8 6.8 3.8 5.5 0.8 7.2 3.8 227 6 225 305 4.7 0 4.9 4.4 06/16/2005 00:30:00 6.3 0.4 7.6 4.9 6 0.5 7.2 4.6 230 5 229 305 4.7 0 4.9 4.4 06/16/2005 00:40:00 5.7 0.5 6.8 4.2 5.2 0.5 6.5 3.8 235 4 231 305 4.6 0 4.9 4.4 06/16/2005 00:50:00 4.7 0.4 5.7 3.8 4.4 0.5 5.7 3.4 238 3 236 305 4.5 0 4.9 4.4 06/16/2005 01:00:00 4.4 0.3 5.3 3.4 4.1 0.3 4.9 3 238 3 237 305 4.5 0.1 4.9 4.4 06/16/2005 01:10:00 3.9 0.3 4.6 3 3.6 0.4 4.6 2.6 235 3 237 305 4.4 0.1 4.7 4.4 06/16/2005 01:20:00 3.8 0.2 4.6 3 3.7 0.3 4.6 3 230 3 229 305 4.4 0 4.7 4.2 06/16/2005 01:30:00 4 0.5 4.9 2.6 3.9 0.4 4.6 2.6 226 4 231 305 4.3 0 4.7 3.9 06/16/2005 01:40:00 3.5 0.3 4.2 3 3.7 0.2 4.2 3 210 3 210 305 3.9 0.1 4.4 3.7 06/16/2005 01:50:00 3.8 0.3 4.6 3 4 0.3 4.9 3 209 4 213 305 3.9 0.1 4.4 3.7 06/16/2005 02:00:00 3.9 0.3 4.9 3 4.1 0.2 4.6 3.4 205 5 218 305 3.8 0 4.4 3.7 06/16/2005 02:10:00 3.8 0.3 4.6 3 4 0.3 4.6 3.4 199 5 196 305 3.8 0 4.4 3.7 06/16/2005 02:20:00 3.7 0.2 4.2 3 4 0.2 4.6 3.4 201 3 205 305 3.7 0 4.2 3.7 06/16/2005 02:30:00 3.6 0.3 4.6 2.6 3.8 0.3 4.6 3 203 5 199 305 3.7 0 4.2 3.7 06/16/2005 02:40:00 3.2 0.3 3.8 2.3 3.5 0.3 4.2 3 203 4 206 305 3.7 0 4.2 3.4 06/16/2005 02:50:00 3.5 0.2 4.2 2.6 3.7 0.2 4.2 3 206 4 208 305 3.7 0 4.2 3.4 06/16/2005 03:00:00 3.2 0.3 4.2 2.6 3.5 0.3 4.2 2.6 203 5 214 305 3.6 0 4.2 3.4 06/16/2005 03:10:00 3.1 0.4 4.2 2.3 3.4 0.4 4.2 2.6 201 5 205 305 3.7 0 4.2 3.4 06/16/2005 03:20:00 3.6 0.4 4.6 2.6 3.8 0.4 4.9 2.6 202 4 203 305 3.7 0 4.2 3.4 06/16/2005 03:30:00 3.9 0.3 4.6 3 4.1 0.3 4.9 3.4 199 4 198 305 3.8 0 4.4 3.7 06/16/2005 03:40:00 3.6 0.4 4.6 2.6 3.8 0.3 4.6 3 196 5 192 305 3.7 0 4.2 3.4 06/16/2005 03:50:00 3.6 0.4 4.6 2.6 3.7 0.4 4.6 2.6 199 6 192 305 3.6 0 4.2 3.4 06/16/2005 04:00:00 3.7 0.3 4.6 2.6 3.9 0.3 4.6 3 204 4 202 305 3.6 0 4.2 3.4 06/16/2005 04:10:00 3.9 0.4 4.9 3 4.1 0.4 4.9 3 209 5 202 305 3.9 0.1 4.4 3.7 06/16/2005 04:20:00 3.7 0.4 4.9 2.6 3.9 0.4 4.9 3 203 6 201 305 4 0.1 4.4 3.7 06/16/2005 04:30:00 3.8 0.4 4.9 3 4 0.4 4.9 3.4 202 5 203 305 4 0.2 4.7 3.7 06/16/2005 04:40:00 3.2 0.3 4.2 2.6 3.5 0.3 4.2 2.6 201 5 197 305 4 0.1 4.4 3.7 06/16/2005 04:50:00 3.2 0.2 3.8 2.6 3.5 0.2 4.2 3 204 4 208 305 4.2 0.1 4.9 3.9 06/16/2005 05:00:00 3.1 0.3 3.8 2.3 3.4 0.3 3.8 2.3 194 4 202 305 4.3 0.1 4.7 4.2 06/16/2005 05:10:00 3.5 0.3 4.2 2.6 3.8 0.2 4.6 3 196 2 198 305 4.4 0.1 4.7 4.2 06/16/2005 05:20:00 3.4 0.2 3.8 3 3.7 0.2 4.2 3 198 3 198 305 4.4 0.1 4.9 4.2 06/16/2005 05:30:00 3.2 0.2 3.8 2.6 3.5 0.2 3.8 2.6 197 2 198 305 4.4 0.1 4.9 4.4 06/16/2005 05:40:00 2.5 0.4 3.4 1.9 2.9 0.3 3.8 2.3 196 3 192 305 4.5 0.1 4.9 4.4 06/16/2005 05:50:00 1.8 0.3 2.3 1.1 2.3 0.2 3 1.9 205 5 201 305 4.7 0 5.2 4.7 06/16/2005 06:00:00 0.8 0.3 1.5 0.4 1.5 0.2 2.3 1.1 217 4 213 305 4.8 0 5.4 4.7 06/16/2005 06:10:00 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 221 1 305 305 5.1 0.2 5.6 4.9 06/16/2005 06:20:00 0.4 0 0.4 0.4 1.2 0.3 1.9 0.7 198 13 305 305 5.5 0.1 5.9 5.4 06/16/2005 06:30:00 0.4 0.1 0.7 0.4 1.3 0.3 2.3 0.7 179 1 179 305 6.2 0.1 6.7 5.6 06/16/2005 06:40:00 0.4 0.1 1.1 0.4 1.1 0.5 2.3 0.4 154 20 159 305 5.7 0.1 6.1 5.4 06/16/2005 06:50:00 1.1 0.5 2.3 0.4 1.7 0.5 2.6 0.7 39 17 25 305 6 0.1 6.4 5.6 06/16/2005 07:00:00 1.2 0.4 1.9 0.4 1.8 0.3 2.3 1.1 6 13 16 305 5.8 0 6.1 5.6 06/16/2005 07:10:00 2.2 0.6 3.4 1.1 2.5 0.6 3.8 1.5 46 10 48 305 6.1 0.1 6.4 5.9 06/16/2005 07:20:00 3.1 0.3 3.8 2.6 3.3 0.3 4.2 2.6 44 5 33 305 6.1 0 6.4 5.9 06/16/2005 07:30:00 3.2 0.3 3.8 2.6 3.4 0.3 4.2 2.6 46 3 46 305 5.8 0.1 6.1 5.4 06/16/2005 07:40:00 3.7 0.3 4.2 3 3.9 0.3 4.6 3 40 2 41 305 5.4 0 5.6 5.2 06/16/2005 07:50:00 3.2 0.3 3.8 2.6 3.4 0.4 4.2 2.6 44 5 39 305 5.4 0 5.6 5.4 06/16/2005 08:00:00 2.4 0.7 4.6 0.7 2.5 0.6 4.6 1.1 87 27 131 305 6 0.3 6.9 5.6 06/16/2005 08:10:00 2.8 1 4.9 0.4 3 0.9 4.9 0.7 96 39 129 305 7 0 7.2 6.7 06/16/2005 08:20:00 2.3 0.6 3.8 0.7 2.5 0.4 3.8 1.5 41 20 62 305 6.9 0 7.2 6.9 06/16/2005 08:30:00 2.5 1 5.7 0.4 2.7 0.9 6.1 0.7 82 22 122 305 7.5 0.2 7.9 7.2 06/16/2005 08:40:00 3.9 1 6.8 1.1 3.8 0.8 6.1 1.9 91 19 58 305 8 0 8.2 7.7 06/16/2005 08:50:00 4.4 0.8 6.8 2.6 4.4 0.7 6.1 3 103 15 112 305 8 0 8.2 7.9 06/16/2005 09:00:00 3.3 0.6 4.6 1.1 3.4 0.6 4.6 1.5 95 17 125 305 8 0.1 8.2 7.7 06/16/2005 09:10:00 3.3 0.4 4.6 2.3 3.4 0.4 4.6 2.3 61 10 72 305 7.4 0 7.9 7.2 06/16/2005 09:20:00 2.3 0.5 4.2 1.1 2.6 0.4 3.8 1.1 42 33 93 305 7.7 0.1 8.2 7.4 06/16/2005 09:30:00 2 1.1 4.6 0.4 2.2 1 4.6 0.4 25 66 78 305 7.6 0.2 7.9 7.4 06/16/2005 09:40:00 2.5 1.5 5.7 0.4 2.5 1.3 4.9 0.4 100 61 93 305 8.2 0.2 8.7 7.9 06/16/2005 09:50:00 2.9 1 5.3 0.4 2.8 1 5.3 0.4 98 69 95 305 9.1 0.2 9.5 8.7 06/16/2005 10:00:00 7.8 1.4 11.5 4.6 7.4 1.3 10.7 4.6 97 6 91 305 8.8 0.4 9.5 8.2 06/16/2005 10:10:00 9.6 0.7 11.1 7.6 9.1 0.7 11.1 7.6 98 5 103 305 8.1 0 8.4 7.9 06/16/2005 10:20:00 9.5 0.7 11.5 6.8 9.1 0.7 11.5 7.2 96 6 94 305 8 0 8.2 7.7 06/16/2005 10:30:00 9.1 0.7 11.1 6.1 8.5 0.7 10.7 6.1 92 5 93 305 8 0.2 8.7 7.7 06/16/2005 10:40:00 9.2 0.6 10.7 7.2 8.7 0.6 10.3 7.2 92 5 97 305 9.1 0.3 9.7 8.4 06/16/2005 10:50:00 9.8 0.8 11.8 8 9.4 0.8 11.5 7.6 95 5 93 305 8 0 8.4 7.7 06/16/2005 11:00:00 9.5 0.8 11.5 7.6 9.1 0.8 11.1 7.2 96 5 100 305 7.9 0.1 8.4 7.7 06/16/2005 11:10:00 8.9 0.7 10.3 5.7 8.5 0.7 10.3 5.7 94 5 90 305 8.6 0 8.9 8.4 06/16/2005 11:20:00 8.9 0.7 10.3 6.8 8.5 0.6 10.3 6.5 90 5 86 305 8.4 0 8.7 8.2 06/16/2005 11:30:00 9.4 0.6 10.7 7.6 8.8 0.6 10.3 6.5 91 5 99 305 8.8 0.1 9.2 8.4 06/16/2005 11:40:00 8.5 0.6 9.5 6.1 8.1 0.6 9.9 6.1 93 6 93 305 8.9 0 9.2 8.7 06/16/2005 11:50:00 8.9 0.9 11.1 5.7 8.6 0.8 10.3 6.8 95 7 100 305 8.6 0.3 9.2 7.9 06/16/2005 12:00:00 9 1.1 11.1 6.1 8.5 1 11.1 6.1 99 7 93 305 8.1 0 8.2 7.9 06/16/2005 12:10:00 9.3 1.2 11.8 6.5 8.9 1.2 11.8 5.7 99 9 95 305 8 0 8.2 7.9 06/16/2005 12:20:00 9.5 0.9 11.5 6.8 9.1 0.9 11.5 6.8 99 8 105 305 8.2 0.1 8.4 7.9 06/16/2005 12:30:00 9.4 1.1 12.2 6.5 9 1.2 11.8 6.1 98 8 97 305 8.2 0 8.4 7.9 06/16/2005 12:40:00 10 1 11.8 7.2 9.6 1 12.2 6.5 99 7 95 305 8.2 0 8.7 8.2 06/16/2005 12:50:00 9.7 1 12.2 6.5 9.4 1 11.8 6.1 102 7 97 305 8.7 0 8.9 8.4 06/16/2005 13:00:00 9.9 1 12.2 6.8 9.6 1 12.2 6.5 100 8 101 305 8.7 0 8.9 8.4 06/16/2005 13:10:00 10 1 12.6 7.2 9.6 1 12.2 6.8 101 7 99 305 8.2 0.2 8.9 7.9 06/16/2005 13:20:00 9.9 1.2 13 6.1 9.5 1.3 12.6 6.1 100 8 92 305 8 0 8.2 7.9 06/16/2005 13:30:00 9.6 1 11.8 6.5 9.3 0.9 11.5 7.2 102 7 97 305 7.9 0.1 8.2 7.7 06/16/2005 13:40:00 9.2 1 11.8 6.5 8.8 1.1 11.5 6.1 101 8 104 305 8.2 0 8.7 7.9 06/16/2005 13:50:00 8.9 1 11.8 6.1 8.6 1 11.1 5.3 99 8 113 305 8.6 0 8.7 8.4 06/16/2005 14:00:00 8.4 1 10.3 4.9 8.2 0.8 10.7 5.3 98 10 99 305 8.4 0 8.7 8.2 06/16/2005 14:10:00 7.7 0.9 9.9 5.7 7.4 0.9 10.3 5.3 102 10 115 305 8.9 0.1 9.2 8.7 06/16/2005 14:20:00 6.6 1.3 9.9 3.4 6.3 1.2 9.5 3 104 12 103 305 9.4 0.2 10 9.2 06/16/2005 14:30:00 5.8 1.1 8.8 2.6 5.6 1.1 8.8 3 113 15 101 305 10.3 0.2 10.8 10 06/16/2005 14:40:00 5.4 1.3 8.8 1.9 5.4 1.3 9.1 2.6 118 16 133 305 11 0.3 11.6 10.5 06/16/2005 14:50:00 5.5 1.2 9.5 1.5 5.4 1.1 9.1 2.3 114 18 119 305 11.3 0 11.6 11 06/16/2005 15:00:00 6.4 1 9.5 3.8 6.2 1 8.4 3.4 101 15 118 305 11.1 0.1 11.6 10.8 06/16/2005 15:10:00 7 1.1 11.1 4.9 6.8 1.2 10.7 4.2 100 16 87 305 10.6 0.2 11 10.2 06/16/2005 15:20:00 6.5 1.5 9.9 1.5 6.4 1.4 10.3 2.6 114 17 118 305 10.9 0.2 11.3 10.5 06/16/2005 15:30:00 6.7 1.8 9.9 1.9 6.6 1.7 10.3 2.3 125 15 119 305 11.3 0 11.3 11 06/16/2005 15:40:00 4.1 1.6 8.4 1.1 4 1.5 9.1 0.7 122 32 152 305 11.6 0 11.8 11.3 06/16/2005 15:50:00 4 1.6 8.4 0.4 3.9 1.5 8.4 0.4 125 43 123 305 11.5 0.1 11.8 11.3 06/16/2005 16:00:00 2.8 1.3 8 0.4 3 1.2 7.2 0.4 120 61 82 305 11.2 0.1 11.6 11 06/16/2005 16:10:00 3.3 1.3 6.5 0.4 3.2 1.2 5.7 0.4 123 69 114 305 11.4 0 11.6 11 06/16/2005 16:20:00 3.4 0.8 5.3 1.5 4.1 0.7 6.1 2.3 337 14 338 305 9.9 0.4 11.3 9.5 06/16/2005 16:30:00 2.3 1 5.3 0.4 3.1 0.8 5.7 0.7 3 61 337 305 9.6 0.1 10 9.2 06/16/2005 16:40:00 2.8 1 5.7 0.4 3 1 6.8 0.7 138 66 174 305 10.6 0.8 11.8 9.5 06/16/2005 16:50:00 3.7 1.1 6.8 1.1 4.1 1.1 7.2 1.1 161 28 145 305 12.4 0.2 12.9 11.8 06/16/2005 17:00:00 3.7 1.1 6.8 1.5 4.1 1 7.6 0.7 174 21 179 305 12.5 0 12.9 12.1 06/16/2005 17:10:00 4.1 1 6.8 1.9 4.4 1 6.8 2.3 165 21 152 305 12.2 0.1 12.4 11.8 06/16/2005 17:20:00 4.6 1.2 7.2 1.5 4.9 1.2 8 1.5 152 21 154 305 12.5 0 12.9 12.4 06/16/2005 17:30:00 3.6 1.1 6.8 1.5 3.7 1 6.8 1.9 165 24 130 305 12.5 0 12.6 12.1 06/16/2005 17:40:00 3.6 1.1 6.8 1.5 3.9 1 6.8 2.3 161 28 131 305 12.3 0 12.4 12.1 06/16/2005 17:50:00 3.7 0.9 6.5 0.7 4.2 0.8 6.5 2.3 175 19 124 305 12 0 12.4 11.8 06/16/2005 18:00:00 4.5 1.1 8.4 1.9 4.9 1.1 8.4 2.3 160 17 152 305 12.2 0 12.4 11.8 06/16/2005 18:10:00 5 1.3 8.8 2.6 5.9 1.1 9.9 3 163 16 144 305 11.6 0.1 11.8 11.3 06/16/2005 18:20:00 5 1.1 7.6 2.6 5.3 1 7.6 3 158 16 131 305 11.9 0.1 12.1 11.6 06/16/2005 18:30:00 5.7 1.1 8.8 2.6 5.9 1 9.1 3.4 142 16 162 305 12.4 0 12.6 12.1 06/16/2005 18:40:00 5.9 0.8 8.4 3.8 5.8 0.8 8 3.8 136 10 131 305 12 0.2 12.4 11.6 06/16/2005 18:50:00 5.6 0.8 8 3.8 5.5 0.8 8 3.8 131 10 134 305 12 0 12.1 11.8 06/16/2005 19:00:00 5.6 0.8 7.6 3.4 5.6 0.7 8 3.4 135 10 159 305 12 0 12.1 11.8 06/16/2005 19:10:00 5.3 1 7.6 3 5.2 1 7.6 2.6 137 10 135 305 12.1 0 12.4 11.8 06/16/2005 19:20:00 4.7 1.1 8 2.3 5.3 1 7.6 2.6 155 16 157 305 12.4 0 12.6 12.1 06/16/2005 19:30:00 5.2 1.3 8.8 2.6 5.6 1 8.8 3.4 156 12 154 305 12.1 0 12.4 11.8 06/16/2005 19:40:00 7.2 1.2 9.9 3.8 7.3 1 9.5 5.3 152 9 152 305 11.4 0.2 11.8 10.8 06/16/2005 19:50:00 7.5 1 9.9 4.2 7.4 0.8 9.9 4.9 151 8 149 305 10.8 0 11 10.8 06/16/2005 20:00:00 6.9 0.8 9.1 4.6 6.9 0.8 8.4 4.2 147 8 161 305 10.6 0 10.8 10.5 06/16/2005 20:10:00 6.7 1 9.5 3.8 6.7 1 9.1 4.2 140 9 140 305 11.1 0.1 11.3 10.8 06/16/2005 20:20:00 7.7 0.7 9.1 6.1 7.6 0.7 9.5 5.7 135 6 131 305 11.3 0 11.3 11.3 06/16/2005 20:30:00 8.4 0.7 9.9 6.5 8.3 0.7 9.9 6.5 136 6 134 305 11 0.1 11.3 10.8 06/16/2005 20:40:00 8.1 0.8 10.3 5.7 8.1 0.8 10.3 6.5 137 6 137 305 10.8 0 11 10.8 06/16/2005 20:50:00 7.5 0.8 9.1 5.3 7.4 0.8 9.5 5.7 134 8 130 305 11 0 11 10.8 06/16/2005 21:00:00 6.6 0.9 8.8 4.6 6.5 1 9.1 4.6 132 8 116 305 11.2 0 11.3 11 06/16/2005 21:10:00 5.9 1.3 8.4 2.3 5.7 1.3 8.8 3 138 12 138 305 11.2 0.1 11.3 11 06/16/2005 21:20:00 3.3 1.6 6.8 0.4 3.5 1.5 6.8 0.4 143 39 148 305 11.1 0 11.3 10.8 06/16/2005 21:30:00 5 0.9 6.8 2.6 5.3 0.9 6.8 3 34 15 31 305 9 0.8 11 8.2 06/16/2005 21:40:00 4.8 0.6 6.5 3 5.1 0.6 7.2 3 51 11 51 305 8.4 0.1 8.7 8.2 06/16/2005 21:50:00 3.4 0.8 5.3 1.1 3.5 0.8 5.3 0.7 79 19 83 305 9.1 0.2 9.5 8.4 06/16/2005 22:00:00 4.9 0.8 6.8 1.5 4.9 0.8 6.5 2.3 73 13 70 305 9.1 0.1 9.7 8.9 06/16/2005 22:10:00 5 0.9 7.2 1.5 5 0.8 7.2 3 76 13 65 305 9.1 0 9.2 8.9 06/16/2005 22:20:00 5 0.8 6.8 3.4 5 0.7 7.2 3.4 75 11 71 305 8.7 0.1 8.9 8.2 06/16/2005 22:30:00 5.1 0.6 6.8 3 5.3 0.6 6.8 3.4 64 8 67 305 7.9 0.3 8.4 7.4 06/16/2005 22:40:00 5.4 0.6 6.8 3 5.7 0.5 6.8 4.2 61 7 64 305 7.4 0 7.9 7.4 06/16/2005 22:50:00 4.9 0.7 7.2 2.6 5.2 0.6 7.2 3 64 12 77 305 7.4 0 7.9 7.4 06/16/2005 23:00:00 4.9 0.8 8 2.6 5.2 0.7 8 2.6 59 12 68 305 7.3 0.1 7.9 7.2 06/16/2005 23:10:00 4.3 0.8 6.8 2.3 4.3 0.7 6.8 2.3 61 12 54 305 7.6 0.2 8.2 7.2 06/16/2005 23:20:00 4.8 0.6 6.8 3 5 0.5 6.5 3.4 54 11 66 305 6.7 0.5 7.9 5.9 06/16/2005 23:30:00 4.2 0.6 6.1 2.6 4.5 0.5 6.1 3 61 9 69 305 6 0 6.4 5.9 06/16/2005 23:40:00 4.6 0.5 5.3 3.4 5.1 0.5 6.1 3.8 52 5 50 305 5.8 0.2 6.4 5.4 06/16/2005 23:50:00 5.4 0.4 6.1 4.6 5.6 0.3 6.1 4.9 50 4 45 305 5.5 0 5.6 5.4 06/17/2005 00:00:00 5.4 0.2 6.1 4.9 5.5 0.3 6.1 4.9 46 3 41 305 5.2 0.1 5.6 4.9 06/17/2005 00:10:00 4.4 0.4 5.3 3.8 4.7 0.5 5.7 3.8 51 4 50 305 5 0 5.4 4.9 06/17/2005 00:20:00 4.9 0.7 6.1 3.8 5 0.7 6.5 3.8 50 5 44 305 5.4 0 5.6 5.4 06/17/2005 00:30:00 4.8 0.8 6.5 3 5.2 0.5 6.5 3.8 62 7 52 305 5.5 0 5.6 5.4 06/17/2005 00:40:00 4 0.6 5.7 1.9 4.1 0.5 5.3 2.6 74 15 60 305 5.8 0.6 7.2 5.2 06/17/2005 00:50:00 5.8 0.7 6.8 3.4 5.4 0.6 6.5 3.4 89 5 84 305 7.6 0.2 7.9 7.2 06/17/2005 01:00:00 6.2 0.4 7.2 4.9 5.8 0.4 6.8 4.6 86 5 87 305 8.1 0 8.2 7.9 06/17/2005 01:10:00 6.1 0.4 6.8 5.3 5.7 0.3 6.5 4.6 84 5 78 305 8.3 0 8.7 7.9 06/17/2005 01:20:00 6.9 0.7 9.1 4.9 6.4 0.7 8.4 4.9 90 5 98 305 8.4 0 8.7 8.2 06/17/2005 01:30:00 8.2 0.7 9.9 6.5 7.7 0.7 9.5 6.1 97 4 103 305 8.2 0.2 8.7 7.7 06/17/2005 01:40:00 8.6 1.1 10.7 4.6 8.2 1.1 10.3 4.6 100 6 103 305 8 0.1 8.4 7.7 06/17/2005 01:50:00 8.9 1 11.1 5.7 8.4 0.9 10.7 5.7 100 6 102 305 8.3 0 8.4 8.2 06/17/2005 02:00:00 9.4 1.1 11.5 5.7 9 1.1 11.1 6.5 100 7 100 305 8.6 0 8.9 8.4 06/17/2005 02:10:00 9.8 1.2 12.2 6.8 9.3 1 11.5 6.5 100 6 92 305 8.8 0 8.9 8.7 06/17/2005 02:20:00 10.1 1.1 13 6.1 9.7 1 12.6 6.5 97 9 94 305 9 0 9.5 8.9 06/17/2005 02:30:00 10.8 0.8 12.2 7.2 10.3 0.9 12.2 6.8 92 5 94 305 9.3 0 9.5 9.2 06/17/2005 02:40:00 11.1 0.7 13.3 8.8 10.6 0.8 13.7 8 92 5 93 305 9.3 0 9.5 9.2 06/17/2005 02:50:00 10.7 1.1 13 7.6 10.2 1.1 13.7 7.2 94 7 92 305 9.1 0 9.2 8.9 06/17/2005 03:00:00 10.6 1.3 13.7 5.7 10 1.3 13.3 6.5 97 8 92 305 8.9 0.1 9.2 8.4 06/17/2005 03:10:00 10.3 1.4 13.3 6.5 9.9 1.4 13 6.5 100 8 102 305 8.2 0.1 8.7 7.9 06/17/2005 03:20:00 10.7 1.2 13.7 7.2 10.2 1.2 13.3 6.8 97 9 105 305 7.7 0 7.9 7.4 06/17/2005 03:30:00 10.7 1.4 14.1 6.1 10.2 1.4 14.5 6.1 97 10 102 305 7.4 0 7.7 7.2 06/17/2005 03:40:00 10.6 1.4 14.5 6.8 10.2 1.4 13.7 6.1 97 9 109 305 7.3 0 7.7 7.2 06/17/2005 03:50:00 10.7 1.6 14.5 6.1 10.3 1.6 13.7 6.5 100 9 99 305 7.3 0 7.7 7.2 06/17/2005 04:00:00 10.2 1.4 13 7.2 9.8 1.3 12.6 6.8 100 8 105 305 7.4 0 7.7 7.2 06/17/2005 04:10:00 10.7 1.4 13.7 5.7 10.2 1.3 13 6.5 99 8 96 305 7.5 0 7.7 7.4 06/17/2005 04:20:00 11.3 1.3 13.7 7.2 10.8 1.2 13 6.8 100 7 101 305 7.8 0 8.2 7.7 06/17/2005 04:30:00 10.9 1.4 13.7 7.2 10.4 1.3 13 6.8 98 8 96 305 8.1 0 8.4 7.9 06/17/2005 04:40:00 11 1.1 13.7 6.8 10.5 1.1 13.7 7.2 100 7 99 305 8.4 0 8.7 8.2 06/17/2005 04:50:00 10.4 1.4 13.7 6.5 9.9 1.3 13 5.7 99 8 108 305 8.5 0 8.7 8.2 06/17/2005 05:00:00 10.3 1.3 13 6.8 10 1.2 12.2 6.8 100 7 100 305 8.6 0 8.7 8.2 06/17/2005 05:10:00 10 1.1 12.2 6.5 9.7 1.1 11.8 6.1 96 8 101 305 8.7 0 8.9 8.4 06/17/2005 05:20:00 10.6 1.1 13.3 6.5 10.1 1.1 13.3 6.5 94 7 92 305 8.6 0 8.9 8.4 06/17/2005 05:30:00 10.6 1.2 13.7 7.2 10.1 1 13 7.6 92 7 95 305 8.4 0.1 8.7 7.9 06/17/2005 05:40:00 10.2 1 12.6 7.6 9.6 0.9 12.6 7.2 88 6 90 305 8.2 0.1 8.4 7.9 06/17/2005 05:50:00 9.8 0.9 12.2 7.6 9.3 0.8 11.5 7.2 85 6 85 305 8.6 0 8.9 8.4 06/17/2005 06:00:00 9.4 0.8 11.5 7.6 9 0.8 10.7 7.2 79 8 88 305 7.7 0.5 8.4 6.9 06/17/2005 06:10:00 12 1.1 14.9 8.8 11.5 1 14.5 8.8 89 7 87 305 8.4 0.2 8.7 7.7 06/17/2005 06:20:00 11.5 1.2 14.1 8.8 11 1.2 13.7 6.5 88 7 77 305 8.6 0 8.7 8.4 06/17/2005 06:30:00 11 0.9 13.3 7.6 10.6 0.9 13 8 88 7 101 305 8.8 0.1 9.2 8.4 06/17/2005 06:40:00 10.1 1 12.2 7.2 9.7 1 12.2 7.6 88 8 90 305 9.3 0 9.5 9.2 06/17/2005 06:50:00 9.9 1 12.2 7.6 9.6 1 11.8 6.8 80 8 72 305 9.1 0.3 9.5 7.9 06/17/2005 07:00:00 10.5 1 13 8.4 10 1 12.2 7.2 77 7 104 305 8.4 0.2 8.9 7.9 06/17/2005 07:10:00 9.6 1.1 12.6 6.8 9.3 1.2 12.2 6.5 76 9 61 305 8.6 0.2 8.9 7.7 06/17/2005 07:20:00 8.5 0.6 10.7 7.2 8.4 0.5 9.9 7.2 59 4 79 305 6.7 0.3 7.7 6.4 06/17/2005 07:30:00 8.8 0.4 9.5 7.6 8.7 0.4 9.5 7.6 59 3 55 305 6.4 0 6.7 6.1 06/17/2005 07:40:00 7.8 0.6 9.5 6.5 7.8 0.5 9.5 6.1 54 4 59 305 6.6 0 6.9 6.4 06/17/2005 07:50:00 7.1 0.4 8 6.1 7.1 0.4 8 5.7 52 4 59 305 6.3 0 6.7 6.1 06/17/2005 08:00:00 7.2 0.4 8 6.1 7.2 0.4 8 5.7 48 4 50 305 6.4 0 6.4 6.1 06/17/2005 08:10:00 7.5 0.4 8.8 6.5 7.5 0.4 9.1 6.5 47 4 54 305 6.3 0 6.4 6.1 06/17/2005 08:20:00 8.4 0.6 10.7 7.2 8.3 0.6 9.9 6.5 55 5 56 305 6.4 0 6.7 6.1 06/17/2005 08:30:00 7.8 0.7 9.9 6.1 7.7 0.7 9.9 6.1 51 6 44 305 6.3 0 6.4 6.1 06/17/2005 08:40:00 7.3 0.6 9.1 6.1 7.2 0.6 9.1 5.7 51 6 52 305 6.1 0.1 6.4 5.9 06/17/2005 08:50:00 7.9 0.6 9.9 6.1 7.7 0.5 9.5 6.1 55 4 60 305 6 0 6.1 5.9 06/17/2005 09:00:00 8.6 0.8 11.1 6.8 8.4 0.8 10.7 6.8 55 5 62 305 6.2 0 6.4 5.9 06/17/2005 09:10:00 8.2 0.6 10.7 6.8 8.2 0.6 9.9 6.8 53 5 61 305 6.4 0 6.7 6.1 06/17/2005 09:20:00 8.6 0.5 10.3 7.6 8.5 0.5 10.3 7.2 58 5 56 305 6.5 0 6.9 6.4 06/17/2005 09:30:00 10.6 0.9 13 8.8 10.4 0.8 12.2 8.8 64 5 75 305 6.9 0.1 7.2 6.7 06/17/2005 09:40:00 10.3 1 12.6 8.4 10.3 1 13 8.4 62 5 71 305 7 0 7.2 6.9 06/17/2005 09:50:00 8.9 0.7 11.1 7.2 8.7 0.6 10.7 7.2 55 5 54 305 6.7 0.1 6.9 6.4 06/17/2005 10:00:00 8.5 0.7 10.3 7.2 8.5 0.7 10.3 6.8 55 5 67 305 6.5 0.1 6.9 6.1 06/17/2005 10:10:00 8.2 0.8 9.9 6.5 8.2 0.7 10.3 6.5 50 5 58 305 6.2 0.3 6.9 5.6 06/17/2005 10:20:00 7.6 0.6 8.8 6.1 7.6 0.6 8.8 6.1 45 3 47 305 5.6 0 5.9 5.4 06/17/2005 10:30:00 6.9 0.5 8 5.7 7 0.5 8.4 5.7 45 4 53 305 5.7 0 5.9 5.6 06/17/2005 10:40:00 6.7 0.4 8 5.7 6.7 0.4 8 5.7 43 4 36 305 5.7 0 5.9 5.6 06/17/2005 10:50:00 6.1 0.3 6.8 5.3 6.2 0.3 6.8 5.3 41 4 37 305 5.9 0 5.9 5.6 06/17/2005 11:00:00 5.5 0.3 6.8 4.9 5.6 0.3 6.5 4.6 38 5 41 305 5.8 0 5.9 5.6 06/17/2005 11:10:00 5.6 0.3 6.5 4.6 5.7 0.3 6.5 4.6 32 4 30 305 5.9 0 5.9 5.9 06/17/2005 11:20:00 5 0.4 6.1 4.2 5.1 0.4 6.5 4.2 36 5 33 305 5.8 0 5.9 5.6 06/17/2005 11:30:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 4.2 25 5 22 305 5.9 0 5.9 5.6 06/17/2005 11:40:00 5.3 0.3 6.1 4.6 5.1 0.4 6.1 4.6 20 3 16 305 5.5 0.1 5.9 5.2 06/17/2005 11:50:00 6.2 0.4 7.6 5.3 6.1 0.4 7.2 4.9 18 3 18 305 4.8 0 5.2 4.7 06/17/2005 12:00:00 6.1 0.4 7.2 4.9 6.1 0.4 7.2 4.9 25 3 22 305 5.3 0.4 5.9 4.9 06/17/2005 12:10:00 4.9 0.6 6.5 3 4.9 0.6 6.5 3.4 44 9 50 305 6.1 0 6.4 5.9 06/17/2005 12:20:00 6.9 1.4 10.3 4.9 6.8 1.3 9.9 4.6 52 6 48 305 6.4 0.2 6.9 6.1 06/17/2005 12:30:00 8 0.8 9.9 6.5 8 0.7 9.9 6.5 58 5 55 305 6.9 0 7.2 6.9 06/17/2005 12:40:00 9.9 0.8 12.2 8.4 9.7 0.8 11.8 8 59 5 55 305 7 0 7.2 6.9 06/17/2005 12:50:00 10.5 0.7 12.2 8.8 10.3 0.7 11.8 8.4 59 5 58 305 7 0 7.2 6.9 06/17/2005 13:00:00 12.2 1.5 14.9 9.5 12 1.3 14.5 9.1 65 7 75 305 7 0.2 7.7 6.9 06/17/2005 13:10:00 11 1.4 13.3 8 10.6 1.4 13.3 6.8 74 7 76 305 7.6 0 7.9 7.4 06/17/2005 13:20:00 9.6 0.9 13.7 8 9.3 0.9 13.3 7.2 71 7 78 305 7.4 0.2 7.9 7.2 06/17/2005 13:30:00 11.8 2.1 16.4 6.8 11.3 2 16.1 6.5 91 12 81 305 7.5 0 7.7 7.2 06/17/2005 13:40:00 7.2 1.4 10.7 3.8 6.9 1.3 9.9 3.8 106 12 85 305 8 0.2 8.4 7.7 06/17/2005 13:50:00 6.3 2.2 9.9 1.1 6.2 2.1 9.9 1.9 107 15 130 305 9.1 0.4 10 8.4 06/17/2005 14:00:00 8.3 1.4 11.8 4.2 8 1.3 11.1 3.8 96 14 89 305 9.4 0.5 10.2 8.7 06/17/2005 14:10:00 8.7 1.5 11.5 5.7 8.4 1.5 11.1 4.9 87 17 93 305 8.4 0.4 9.2 7.7 06/17/2005 14:20:00 11.3 1.1 13.7 8.8 11 1 13.3 8.8 93 7 93 305 8.6 0.3 9.2 8.2 06/17/2005 14:30:00 11.6 1 14.9 8.8 11.3 1 14.9 9.1 96 7 83 305 8.2 0.1 8.7 7.9 06/17/2005 14:40:00 10.6 1.3 13 7.2 10.5 1.2 12.6 6.5 110 7 99 305 8.8 0.1 9.2 8.4 06/17/2005 14:50:00 7.4 0.9 9.9 4.9 7.2 0.9 9.9 4.9 113 9 135 305 9.4 0.1 9.7 9.2 06/17/2005 15:00:00 5.5 1 8.4 3.4 5.4 1 8.8 3.4 109 13 118 305 10.2 0.2 10.8 9.7 06/17/2005 15:10:00 6.2 0.8 8 3.8 6.1 0.8 8 4.2 108 11 114 305 10.2 0.2 10.8 9.7 06/17/2005 15:20:00 6.1 0.8 8.4 3.8 6 0.8 8.4 3.8 107 13 130 305 10.6 0.2 10.8 10 06/17/2005 15:30:00 6.1 1 8 3 5.9 1 8 3 125 10 131 305 11 0.3 11.8 10.5 06/17/2005 15:40:00 4.3 1 6.8 1.9 4.4 0.9 6.8 2.3 115 22 129 305 11.8 0.2 12.4 11.3 06/17/2005 15:50:00 5 1.1 8.4 2.3 5 1.1 8 2.6 130 17 160 305 12.5 0 12.9 12.1 06/17/2005 16:00:00 4.3 1 6.1 1.9 4.2 0.9 6.1 1.9 114 16 110 305 12 0 12.4 11.8 06/17/2005 16:10:00 4.1 0.9 6.5 1.9 4.1 0.8 6.1 2.3 114 17 106 305 11.7 0 12.1 11.6 06/17/2005 16:20:00 5 0.8 6.8 2.3 5 0.7 6.8 3 124 12 93 305 11.4 0 11.8 11.3 06/17/2005 16:30:00 3.8 0.8 5.7 2.3 3.9 0.8 6.1 2.3 97 20 143 305 11.1 0 11.3 11 06/17/2005 16:40:00 4.3 0.7 6.5 3 4.3 0.7 7.6 3 92 12 88 305 11 0 11.3 10.8 06/17/2005 16:50:00 4 0.8 6.8 1.5 4.1 0.8 6.5 1.9 82 15 82 305 10.8 0 11.3 10.8 06/17/2005 17:00:00 2.5 1 4.9 0.4 2.5 1 5.7 0.4 99 36 101 305 11 0 11.3 10.8 06/17/2005 17:10:00 2.5 0.8 4.6 0.4 2.6 0.7 4.6 0.7 66 32 100 305 10.7 0 11.3 10.5 06/17/2005 17:20:00 3 1 5.7 0.4 3.2 0.8 5.7 1.1 61 21 54 305 10.5 0.2 11.3 10.2 06/17/2005 17:30:00 2.9 0.7 4.6 1.1 3 0.6 4.6 1.1 82 13 84 305 10.2 0 10.8 10 06/17/2005 17:40:00 2.5 1.1 4.6 0.4 2.8 0.9 5.3 1.1 62 22 103 305 10.2 0 10.5 10.2 06/17/2005 17:50:00 4 1 6.5 1.5 4.1 0.9 7.2 1.9 59 20 74 305 9.6 0.6 10.5 8.4 06/17/2005 18:00:00 4.2 0.6 6.1 2.3 4.2 0.5 5.7 2.6 68 13 65 305 7.9 0.4 8.9 7.2 06/17/2005 18:10:00 3.8 0.4 5.3 3 4.2 0.3 4.9 3.4 54 5 68 305 6.7 0.2 7.2 6.4 06/17/2005 18:20:00 4.4 0.5 5.3 3.4 4.6 0.5 5.7 3.4 49 7 46 305 6.2 0.2 6.4 5.9 06/17/2005 18:30:00 5 0.4 6.1 4.2 5.1 0.4 6.5 4.2 49 4 48 305 6 0 6.1 5.9 06/17/2005 18:40:00 5.4 0.3 6.1 4.6 5.6 0.3 6.1 4.9 56 4 54 305 6.1 0 6.4 5.9 06/17/2005 18:50:00 5.4 0.4 6.5 4.2 5.4 0.4 6.5 4.6 61 4 59 305 6.5 0 6.9 6.4 06/17/2005 19:00:00 5 0.4 6.5 4.2 5 0.5 6.1 4.2 64 4 63 305 6.6 0 6.9 6.4 06/17/2005 19:10:00 6.3 0.5 7.2 4.9 6.5 0.5 7.2 4.9 59 5 61 305 6.3 0 6.4 6.1 06/17/2005 19:20:00 6.1 0.6 7.2 4.9 6.1 0.6 7.6 4.6 63 6 59 305 6.2 0 6.4 6.1 06/17/2005 19:30:00 5.6 0.6 7.6 4.2 5.4 0.5 7.2 4.2 67 7 83 305 6.3 0 6.4 6.1 06/17/2005 19:40:00 6.5 1 9.1 4.6 6.2 0.8 8.8 4.6 70 8 70 305 6.3 0.2 7.2 6.1 06/17/2005 19:50:00 5.8 0.9 7.6 4.2 5.6 0.8 7.6 4.2 72 7 78 305 6.8 0 7.4 6.7 06/17/2005 20:00:00 7.2 0.9 9.9 4.9 7 1 9.5 4.6 64 6 58 305 6.8 0 7.2 6.7 06/17/2005 20:10:00 7.8 0.7 9.9 6.1 7.6 0.7 9.9 5.7 62 6 66 305 6.7 0.2 7.2 6.4 06/17/2005 20:20:00 8.1 0.6 9.9 6.5 7.8 0.7 9.5 5.7 63 5 68 305 6.1 0.1 6.4 5.9 06/17/2005 20:30:00 8.5 0.7 10.7 6.8 8.2 0.7 10.3 5.7 64 4 70 305 5.9 0 5.9 5.6 06/17/2005 20:40:00 8.7 0.6 10.3 7.2 8.2 0.6 9.9 6.8 73 5 75 305 6 0.1 6.4 5.9 06/17/2005 20:50:00 7.9 0.6 9.9 5.7 7.4 0.6 9.5 6.1 73 5 76 305 6.1 0 6.4 5.9 06/17/2005 21:00:00 7.1 1 9.9 4.2 6.8 0.9 9.9 4.2 70 9 82 305 6.5 0.1 6.9 6.1 06/17/2005 21:10:00 6.3 0.7 8 4.6 6.2 0.8 8 4.2 61 7 68 305 6.1 0.1 6.4 5.9 06/17/2005 21:20:00 6.5 0.7 8.4 4.9 6.4 0.7 8 4.9 63 6 62 305 5.9 0 6.1 5.9 06/17/2005 21:30:00 7.3 0.7 9.9 5.7 7.1 0.6 9.5 5.7 70 6 72 305 6.1 0.2 6.7 5.9 06/17/2005 21:40:00 7.6 0.9 10.3 5.7 7.3 0.9 9.5 5.3 78 7 69 305 6.7 0 7.2 6.4 06/17/2005 21:50:00 9.1 1.2 11.8 6.5 8.5 1.2 11.8 6.1 87 8 75 305 6.7 0 6.9 6.4 06/17/2005 22:00:00 9.1 1.2 11.8 6.5 8.4 1.1 11.8 5.7 88 8 85 305 6.5 0 6.9 6.4 06/17/2005 22:10:00 9.1 1 11.8 6.5 8.3 1 11.1 5.7 87 8 99 305 6.4 0 6.4 6.1 06/17/2005 22:20:00 8.7 1 11.5 5.7 8.3 1.1 11.8 5.7 87 8 90 305 6.3 0 6.4 6.1 06/17/2005 22:30:00 8.4 1.3 11.1 2.6 8 1.2 11.5 3.8 91 10 102 305 6.5 0 6.7 6.4 06/17/2005 22:40:00 8.5 1.2 11.5 4.9 8 1.2 11.5 4.2 87 9 88 305 6.5 0 6.7 6.1 06/17/2005 22:50:00 9.5 1.3 12.6 5.3 8.9 1.2 11.8 4.6 87 9 75 305 6.5 0 6.9 6.4 06/17/2005 23:00:00 9.2 1.2 12.6 5.3 8.6 1.3 11.8 4.9 94 9 87 305 6.6 0 6.9 6.4 06/17/2005 23:10:00 8.3 1.5 12.6 5.3 7.9 1.5 11.8 4.9 94 9 100 305 6.5 0 6.7 6.1 06/17/2005 23:20:00 9.1 1.1 11.8 6.1 8.6 1 11.1 6.1 94 11 95 305 6.5 0 6.7 6.4 06/17/2005 23:30:00 7.7 1.5 10.3 2.6 7.3 1.3 10.7 3.8 95 13 90 305 6.5 0 6.7 6.1 06/17/2005 23:40:00 8.8 1.2 13 5.7 8.3 1.2 11.5 4.9 90 11 67 305 6.5 0 6.7 6.4 06/17/2005 23:50:00 10.2 1.1 12.6 6.5 9.7 1.1 12.2 6.8 90 8 85 305 6.7 0 7.2 6.4 06/18/2005 00:00:00 9.9 1.3 12.6 7.2 9.3 1.3 12.2 6.1 89 8 86 305 7 0 7.4 6.9 06/18/2005 00:10:00 9.7 1.1 12.6 6.1 9.2 1.1 11.8 6.5 89 9 90 305 7 0 7.2 6.9 06/18/2005 00:20:00 9.2 1.2 11.8 6.1 8.6 1.2 11.5 4.6 92 8 89 305 7 0 7.2 6.9 06/18/2005 00:30:00 9.4 1.5 12.6 5.7 8.9 1.4 12.2 4.9 92 9 94 305 7 0 7.2 6.9 06/18/2005 00:40:00 9.7 1.4 12.6 5.3 9.1 1.4 12.2 4.6 89 9 92 305 7 0 7.2 6.9 06/18/2005 00:50:00 9.7 1.3 12.2 6.1 9.2 1.3 11.8 6.1 91 9 82 305 6.8 0 7.2 6.4 06/18/2005 01:00:00 9.8 1.2 12.6 6.5 9.3 1.2 13 6.5 89 11 91 305 6.7 0 6.9 6.7 06/18/2005 01:10:00 9.7 1.1 12.2 5.3 9.2 1.1 11.8 6.1 89 10 77 305 6.6 0 6.9 6.4 06/18/2005 01:20:00 9.8 1.4 14.5 6.5 9.3 1.3 14.1 5.7 90 9 85 305 6.5 0 6.7 6.4 06/18/2005 01:30:00 9.9 1.3 12.6 5.7 9.5 1.4 12.2 6.1 91 11 100 305 6.5 0 6.7 6.4 06/18/2005 01:40:00 10.2 1.3 12.6 6.5 9.6 1.2 11.8 6.1 93 9 102 305 6.4 0 6.7 6.1 06/18/2005 01:50:00 9.3 1.4 13 6.1 8.8 1.3 12.2 5.7 90 11 91 305 6.3 0 6.4 6.1 06/18/2005 02:00:00 9.2 1.3 12.6 6.1 8.8 1.1 11.5 5.7 93 9 96 305 6.4 0 6.7 6.1 06/18/2005 02:10:00 9.3 1.3 12.2 5.3 8.8 1.2 12.6 5.7 92 8 87 305 6.3 0 6.4 6.1 06/18/2005 02:20:00 9.6 1.3 12.2 6.5 9 1.3 12.2 6.1 94 8 99 305 6.4 0 6.7 6.1 06/18/2005 02:30:00 9.2 1.3 12.2 5.7 8.7 1.2 11.5 5.7 97 10 102 305 6.5 0 6.9 6.4 06/18/2005 02:40:00 9.3 1.3 12.2 6.1 8.8 1.1 11.5 5.3 98 8 101 305 6.5 0 6.7 6.1 06/18/2005 02:50:00 9 1.2 11.8 5.7 8.5 1.1 11.1 6.1 99 9 106 305 6.5 0 6.9 6.4 06/18/2005 03:00:00 8.7 1.2 11.5 5.3 8.3 1.2 11.5 5.3 98 9 89 305 6.6 0 6.9 6.4 06/18/2005 03:10:00 8.4 1 10.7 6.1 7.9 1 10.3 5.3 100 8 103 305 6.8 0 7.2 6.7 06/18/2005 03:20:00 7.9 1 9.9 5.7 7.5 0.8 9.1 5.3 99 7 101 305 7.1 0 7.4 6.9 06/18/2005 03:30:00 8.2 1.1 11.1 5.3 7.8 1 10.3 4.6 97 7 103 305 7.1 0 7.4 7.2 06/18/2005 03:40:00 8.1 0.9 10.3 6.1 7.7 0.9 9.5 5.3 100 7 94 305 7.1 0 7.4 6.9 06/18/2005 03:50:00 6.9 0.9 8.8 4.2 6.7 0.9 9.1 4.9 99 9 86 305 7.3 0 7.7 7.2 06/18/2005 04:00:00 6.3 1.4 9.9 3 6 1.3 10.3 2.6 111 13 140 305 7.2 0.1 7.4 7.2 06/18/2005 04:10:00 6.5 0.9 9.5 3 6.1 0.9 8.4 3.4 122 10 116 305 7 0 7.2 6.9 06/18/2005 04:20:00 7.1 1 9.5 4.9 6.9 1 9.1 4.9 124 11 117 305 7 0 7.2 6.9 06/18/2005 04:30:00 6.7 1 9.1 3.8 6.5 1 9.1 4.2 132 8 143 305 6.7 0.1 6.9 6.4 06/18/2005 04:40:00 6.7 0.6 8.4 4.9 6.6 0.6 8 4.9 133 6 133 305 6.5 0 6.9 6.1 06/18/2005 04:50:00 7.1 0.6 8.4 5.3 6.9 0.6 8 4.9 136 5 140 305 6.5 0 6.9 6.4 06/18/2005 05:00:00 7.5 0.4 8.4 6.1 7.2 0.4 8 5.7 139 3 139 305 6.7 0 6.9 6.4 06/18/2005 05:10:00 7.7 0.3 8.4 6.5 7.4 0.4 8 6.1 140 2 142 305 6.5 0 6.7 6.4 06/18/2005 05:20:00 7.7 0.3 8.4 6.5 7.3 0.4 8 6.1 141 2 143 305 6.3 0 6.4 6.1 06/18/2005 05:30:00 7.9 0.4 8.8 6.8 7.4 0.5 8.4 5.7 142 2 144 305 6.1 0 6.4 6.1 06/18/2005 05:40:00 5.9 1.1 8 3 6.2 0.7 7.6 4.2 168 21 144 305 6 0.1 6.4 5.6 06/18/2005 05:50:00 4.4 1 6.1 2.6 5.4 0.6 6.8 3.4 184 13 212 305 6 0.1 6.4 5.6 06/18/2005 06:00:00 5.4 0.5 6.5 3.4 5 0.7 6.5 3 207 7 214 305 4.9 0.2 5.6 4.4 06/18/2005 06:10:00 4.9 0.4 5.7 3.8 4.9 0.5 6.1 3.4 195 4 198 305 4.5 0 4.9 4.4 06/18/2005 06:20:00 5.4 0.6 6.8 3.8 5.3 0.6 6.8 3.8 195 3 194 305 4.3 0 4.7 4.2 06/18/2005 06:30:00 6.9 0.5 8.4 5.7 6.9 0.5 8.4 5.3 193 4 192 305 4.2 0 4.4 4.2 06/18/2005 06:40:00 6.2 0.5 8 4.6 6.1 0.6 7.6 4.2 194 4 192 305 4.1 0 4.4 3.9 06/18/2005 06:50:00 7.3 0.7 9.1 5.7 7.1 0.7 8.8 4.6 192 4 192 305 4.2 0 4.7 3.9 06/18/2005 07:00:00 6.4 0.6 8 4.6 6.3 0.6 7.6 4.9 188 4 186 305 4.4 0 4.7 4.2 06/18/2005 07:10:00 6.1 0.6 7.6 4.6 6.3 0.5 7.6 4.6 188 5 196 305 4.4 0 4.7 4.2 06/18/2005 07:20:00 6.1 0.5 7.2 4.6 6.1 0.5 7.2 4.9 189 4 188 305 4.4 0 4.7 4.2 06/18/2005 07:30:00 6.6 0.5 8 4.9 6.7 0.5 8 4.9 189 4 188 305 4.4 0 4.7 4.2 06/18/2005 07:40:00 7.3 0.5 8.4 5.7 7.1 0.6 8.4 5.3 193 4 193 305 4.1 0.1 4.4 3.9 06/18/2005 07:50:00 8 0.5 9.1 6.1 7.6 0.6 9.1 5.3 192 3 190 305 4.2 0 4.4 3.9 06/18/2005 08:00:00 7.7 0.5 8.8 6.1 7.4 0.6 9.1 5.7 191 3 193 305 4.2 0 4.7 4.2 06/18/2005 08:10:00 7.3 0.5 8.8 6.1 7.1 0.6 8.8 5.3 193 3 190 305 4.2 0 4.7 4.2 06/18/2005 08:20:00 6.5 0.4 7.2 4.9 6.3 0.5 7.2 4.6 197 4 191 305 4.1 0.1 4.4 3.9 06/18/2005 08:30:00 6.4 0.4 7.6 5.3 6.3 0.4 7.6 4.9 196 5 191 305 4 0.1 4.4 3.7 06/18/2005 08:40:00 6.5 0.4 7.2 5.3 6.5 0.5 7.6 4.6 194 4 194 305 3.9 0.1 4.4 3.7 06/18/2005 08:50:00 6.7 0.5 8 5.7 6.4 0.6 7.6 4.9 196 4 194 305 3.8 0 4.2 3.7 06/18/2005 09:00:00 6.2 0.4 7.2 5.3 6.1 0.4 6.8 4.9 203 5 204 305 3.7 0 4.2 3.4 06/18/2005 09:10:00 6 0.4 6.8 4.6 5.9 0.5 7.2 4.6 198 5 206 305 3.7 0 4.2 3.4 06/18/2005 09:20:00 7.2 0.8 8.8 5.3 6.9 0.9 8.8 4.9 214 6 214 305 4 0.2 4.4 3.4 06/18/2005 09:30:00 7.4 0.6 8.8 5.7 7.1 0.7 8.4 5.7 217 5 218 305 4.2 0 4.7 4.2 06/18/2005 09:40:00 6.6 0.9 8.4 4.2 6.2 1 8.4 3.8 211 5 211 305 4.2 0 4.7 4.2 06/18/2005 09:50:00 6.9 0.7 8.4 4.9 6.6 0.7 8 4.6 215 5 212 305 4.2 0 4.7 4.2 06/18/2005 10:00:00 7.8 0.7 9.5 6.1 7.6 0.8 9.1 5.3 213 4 214 305 4.2 0 4.7 4.2 06/18/2005 10:10:00 7.5 0.6 8.8 5.3 7.2 0.7 8.8 5.3 216 5 217 305 4.3 0 4.7 4.2 06/18/2005 10:20:00 7.6 0.7 9.1 5.3 7.2 0.8 9.1 4.9 217 4 218 305 4.4 0 4.9 4.4 06/18/2005 10:30:00 8.3 0.6 9.5 6.5 7.8 0.7 9.5 5.7 220 4 213 305 4.5 0.1 4.9 4.4 06/18/2005 10:40:00 7.5 0.8 9.1 5.3 7.1 0.8 8.8 4.6 218 6 218 305 4.5 0.1 4.9 4.4 06/18/2005 10:50:00 8.9 0.9 10.7 6.1 8.4 1 10.7 5.3 212 5 209 305 4.5 0.1 4.9 4.2 06/18/2005 11:00:00 9 0.7 10.7 6.5 8.6 0.8 10.3 6.1 212 5 201 305 4.3 0 4.9 4.2 06/18/2005 11:10:00 8.9 0.7 10.3 6.5 8.6 0.8 10.3 6.5 211 4 213 305 4.5 0.1 4.9 4.4 06/18/2005 11:20:00 9 0.9 11.1 6.5 8.6 1.1 11.1 6.1 213 5 217 305 4.6 0 4.9 4.4 06/18/2005 11:30:00 8.8 0.9 10.7 6.5 8.5 1 10.3 5.7 214 4 208 305 4.5 0.1 4.9 4.4 06/18/2005 11:40:00 7.9 0.7 9.9 5.3 7.6 0.9 9.5 4.9 214 4 208 305 4.5 0.1 4.9 4.4 06/18/2005 11:50:00 8 0.9 9.9 5.3 7.5 1.1 9.9 4.9 209 5 205 305 4.5 0.1 4.9 4.4 06/18/2005 12:00:00 8.2 0.7 9.9 6.1 7.8 1 9.9 5.3 215 4 214 305 4.7 0 5.2 4.4 06/18/2005 12:10:00 7.5 0.8 9.1 4.9 7.2 0.9 9.1 4.9 214 4 217 305 4.8 0 5.4 4.7 06/18/2005 12:20:00 6.7 0.7 8.4 4.2 6.5 0.8 8.4 4.2 210 5 205 305 4.9 0 5.4 4.9 06/18/2005 12:30:00 6.9 0.4 8 5.7 6.9 0.5 8 4.9 201 3 202 305 4.9 0 5.4 4.7 06/18/2005 12:40:00 7 0.6 8.4 5.7 6.8 0.6 8.8 4.9 196 4 194 305 5 0.1 5.4 4.9 06/18/2005 12:50:00 6.9 0.4 8 4.9 6.8 0.6 8 4.9 195 3 196 305 5 0.1 5.4 4.9 06/18/2005 13:00:00 7.6 0.4 8.4 6.5 7.5 0.5 8.8 5.7 195 4 198 305 5.1 0 5.4 4.9 06/18/2005 13:10:00 7.3 0.5 8.8 5.3 7.1 0.6 8.4 5.3 193 4 185 305 5.3 0 5.4 4.9 06/18/2005 13:20:00 7.5 0.6 8.8 5.3 7.1 0.7 8.4 4.9 195 4 190 305 5.3 0 5.6 5.2 06/18/2005 13:30:00 7.7 0.5 8.8 6.1 7.4 0.6 8.8 5.3 197 4 192 305 5.5 0 5.6 5.4 06/18/2005 13:40:00 7.9 0.5 9.1 6.5 7.6 0.6 9.1 5.7 199 4 203 305 5.5 0 5.9 5.4 06/18/2005 13:50:00 8.2 0.5 9.1 6.8 8 0.6 9.5 6.1 205 4 208 305 5.4 0 5.6 5.4 06/18/2005 14:00:00 8.1 0.5 9.5 6.5 8 0.6 9.5 5.7 203 4 200 305 5.4 0 5.6 5.4 06/18/2005 14:10:00 7.5 0.5 8.8 6.1 7.3 0.6 9.1 4.9 201 3 203 305 5.5 0 5.6 5.4 06/18/2005 14:20:00 7.6 0.8 9.5 4.9 7.2 0.9 9.5 4.6 209 5 204 305 5.7 0 5.9 5.4 06/18/2005 14:30:00 8.1 0.6 9.5 5.3 7.8 0.7 9.5 5.7 206 5 206 305 5.7 0 5.9 5.6 06/18/2005 14:40:00 8.3 0.7 9.9 5.7 8 0.8 9.9 5.7 208 6 208 305 5.9 0 5.9 5.6 06/18/2005 14:50:00 8.2 0.7 9.5 5.7 7.7 0.8 9.1 5.3 210 5 205 305 5.9 0 5.9 5.9 06/18/2005 15:00:00 8.4 0.9 10.3 5.3 7.9 1 9.9 5.7 209 6 207 305 5.9 0 6.1 5.6 06/18/2005 15:10:00 8.2 0.9 10.7 5.3 7.6 1 9.5 4.9 210 6 208 305 5.9 0 5.9 5.9 06/18/2005 15:20:00 8.4 0.8 10.3 6.1 7.7 0.8 9.9 5.7 211 6 211 305 6 0 6.1 5.9 06/18/2005 15:30:00 8.1 0.7 10.3 5.7 7.4 0.9 9.5 5.3 211 6 203 305 6 0 6.1 5.9 06/18/2005 15:40:00 8 0.7 9.5 5.7 7.4 0.8 8.8 4.9 210 6 217 305 6.3 0 6.7 5.9 06/18/2005 15:50:00 8 0.6 9.5 6.1 7.5 0.7 9.5 5.3 209 5 210 305 6 0 6.1 5.6 06/18/2005 16:00:00 7.8 0.8 9.5 5.7 7.2 0.9 9.1 4.6 212 5 222 305 5.9 0 5.9 5.6 06/18/2005 16:10:00 6.7 1 8.4 3.4 6.1 0.9 8 3.8 209 7 213 305 6.3 0.3 7.2 5.9 06/18/2005 16:20:00 6.5 0.8 8.4 4.2 6 0.8 8 4.2 212 7 217 305 6.5 0.3 7.2 5.9 06/18/2005 16:30:00 6 0.7 7.6 3.8 5.8 0.7 7.6 3.8 203 8 208 305 5.8 0 6.1 5.6 06/18/2005 16:40:00 5.8 0.6 7.2 4.2 5.5 0.6 7.2 3.8 207 5 213 305 5.8 0 5.9 5.6 06/18/2005 16:50:00 5 0.7 6.5 3 4.8 0.7 6.5 3 202 7 196 305 5.7 0 5.9 5.6 06/18/2005 17:00:00 5.5 0.9 8.4 3 6.3 1.5 9.9 3.8 185 13 174 305 6.3 0.4 7.2 5.9 06/18/2005 17:10:00 5.9 1.3 9.1 3 7.9 1.1 10.3 4.9 175 8 179 305 7.1 0 7.4 6.9 06/18/2005 17:20:00 7.2 0.8 10.3 4.6 7.4 1 10.7 5.7 197 10 186 305 6.2 0.6 7.2 5.4 06/18/2005 17:30:00 6.5 0.7 8 4.6 6.1 0.8 8.8 3.8 208 7 192 305 5.8 0.1 5.9 5.4 06/18/2005 17:40:00 6.2 0.7 8 4.2 5.8 0.7 7.6 3.4 215 7 217 305 5.6 0.2 5.9 5.4 06/18/2005 17:50:00 5.5 0.8 7.2 3.4 5.2 0.9 6.8 3 206 10 209 305 5.4 0 5.6 5.4 06/18/2005 18:00:00 6.1 0.9 7.6 3.8 5.9 0.8 7.6 3.8 195 7 198 305 5.3 0 5.6 5.2 06/18/2005 18:10:00 5.3 0.9 7.2 3 5 0.8 6.8 3 197 6 203 305 5.4 0.1 5.6 5.2 06/18/2005 18:20:00 5.8 0.8 7.6 3.8 5.5 0.8 7.6 3 207 5 208 305 5.5 0 5.6 5.4 06/18/2005 18:30:00 6 0.8 7.2 3.8 5.4 0.8 6.8 3 211 6 213 305 5.5 0 5.6 5.4 06/18/2005 18:40:00 6.3 0.7 8 4.2 5.6 0.8 7.6 3.4 213 6 221 305 5.7 0 5.9 5.4 06/18/2005 18:50:00 6.1 0.7 8 3.8 5.6 0.8 7.2 3.4 206 7 204 305 5.9 0 5.9 5.6 06/18/2005 19:00:00 5.1 0.7 6.8 3.4 5 0.6 6.5 3.4 194 7 190 305 5.8 0 5.9 5.6 06/18/2005 19:10:00 6.1 0.5 7.6 4.2 5.8 0.5 7.2 3.8 203 6 187 305 5.6 0 5.9 5.6 06/18/2005 19:20:00 5.6 0.6 6.8 3 5.4 0.5 6.8 3.8 198 7 202 305 5.9 0.1 6.1 5.6 06/18/2005 19:30:00 6.7 1 9.1 4.2 6.9 1.2 9.1 3.8 186 6 188 305 6.8 0.4 7.4 6.1 06/18/2005 19:40:00 6 1.7 9.1 3 7.1 1 9.9 4.6 180 9 192 305 7.3 0 7.7 7.2 06/18/2005 19:50:00 5.5 1.2 8.4 2.6 5.4 1.2 8.4 2.3 201 16 188 305 6.8 0.2 7.2 6.1 06/18/2005 20:00:00 4.8 0.5 6.5 3.4 4.3 0.5 5.7 3 215 7 207 305 5.9 0 6.1 5.6 06/18/2005 20:10:00 5.1 0.8 7.6 3.4 5.1 1.2 8 3 198 13 188 305 6 0.3 6.9 5.6 06/18/2005 20:20:00 5.8 1.4 9.1 2.6 7.5 1 9.9 5.3 175 8 172 305 7 0 7.2 6.9 06/18/2005 20:30:00 5.5 1 9.1 3.4 7.5 0.7 9.5 5.3 169 6 160 305 7 0 7.2 6.9 06/18/2005 20:40:00 5 1 8 2.3 7.1 0.8 8.4 4.6 169 6 160 305 7 0 7.2 6.9 06/18/2005 20:50:00 5.1 1.1 8 3 6.8 0.7 8.8 4.9 167 6 162 305 7 0 7.2 6.9 06/18/2005 21:00:00 5.4 1 8 3 7.1 0.8 9.1 4.9 166 8 157 305 6.9 0 7.2 6.9 06/18/2005 21:10:00 6.1 1.3 9.5 3 6.5 1 9.1 4.2 157 10 144 305 6.6 0 6.9 6.4 06/18/2005 21:20:00 6.5 1.2 8.8 3.4 6.8 0.8 9.1 4.2 154 9 155 305 6.4 0 6.4 6.1 06/18/2005 21:30:00 5.6 1.2 8.4 3 6.7 0.8 9.5 4.6 163 9 166 305 6.1 0 6.4 5.9 06/18/2005 21:40:00 5.2 1 7.6 3 7.1 0.8 9.1 4.6 168 6 158 305 6.2 0 6.4 6.1 06/18/2005 21:50:00 5.1 1.1 8 2.3 5.7 0.8 7.6 3.4 158 10 149 305 6.1 0 6.4 6.1 06/18/2005 22:00:00 5.9 1 7.6 3 5.9 0.7 8 3.4 150 7 156 305 6.1 0 6.1 5.9 06/18/2005 22:10:00 5.9 0.8 8 3.4 5.9 0.7 7.6 4.2 146 8 151 305 6 0 6.1 5.9 06/18/2005 22:20:00 5.2 1.3 8.8 2.3 5.5 1 8.4 3 153 11 152 305 5.8 0 5.9 5.6 06/18/2005 22:30:00 4.7 0.9 6.8 2.3 5.4 0.8 8 3.4 158 10 163 305 5.8 0 5.9 5.6 06/18/2005 22:40:00 6.1 1 8.4 3.8 5.9 0.8 8.4 3.8 148 9 154 305 5.8 0 5.9 5.6 06/18/2005 22:50:00 6.2 0.9 8 3.8 6.2 0.8 8 4.2 147 8 151 305 5.6 0.1 5.9 5.4 06/18/2005 23:00:00 6.4 0.8 8.4 3.8 6.3 0.7 7.6 4.6 149 7 133 305 5.3 0 5.6 5.2 06/18/2005 23:10:00 5.6 0.9 8 3.4 5.6 0.8 7.6 3.8 141 9 143 305 5.3 0 5.6 5.2 06/18/2005 23:20:00 6.3 1 9.1 3.8 6.2 0.8 8.8 4.2 145 9 148 305 5.2 0 5.6 4.9 06/18/2005 23:30:00 6.7 0.8 8.8 4.9 6.6 0.8 8.8 4.6 142 8 150 305 5.2 0 5.4 4.9 06/18/2005 23:40:00 7 0.5 8.4 4.9 7 0.5 8.4 5.7 136 5 141 305 5 0.1 5.4 4.9 06/18/2005 23:50:00 7.7 0.6 9.5 6.5 7.4 0.6 9.1 6.1 137 4 137 305 5 0.1 5.4 4.9 06/19/2005 00:00:00 7.3 0.8 9.1 5.3 7.3 0.7 9.1 5.3 141 6 139 305 4.9 0 5.4 4.9 06/19/2005 00:10:00 6.9 0.8 8 4.9 6.8 0.7 8 4.9 134 4 134 305 4.9 0.1 5.4 4.9 06/19/2005 00:20:00 8.2 0.5 9.1 6.8 8 0.5 9.1 6.8 136 3 137 305 4.9 0 5.4 4.9 06/19/2005 00:30:00 8.2 0.5 9.1 6.8 8 0.5 9.1 6.8 134 3 136 305 4.9 0 5.4 4.7 06/19/2005 00:40:00 8 0.4 9.9 6.8 7.9 0.4 9.9 6.5 137 3 139 305 4.8 0 5.4 4.7 06/19/2005 00:50:00 8.2 0.9 10.3 6.1 8.1 0.9 10.3 6.1 146 6 151 305 4.8 0 5.2 4.7 06/19/2005 01:00:00 9.1 0.7 10.7 6.1 8.8 0.6 10.3 7.2 151 5 154 305 4.8 0 5.2 4.7 06/19/2005 01:10:00 8.6 0.6 10.3 6.8 8.3 0.6 9.9 6.1 148 4 152 305 4.8 0 5.2 4.7 06/19/2005 01:20:00 7.1 0.9 9.1 4.6 7.1 0.9 9.1 4.6 142 7 152 305 4.5 0.1 4.9 4.4 06/19/2005 01:30:00 7.4 0.6 8.8 5.7 7.2 0.6 8.8 5.3 135 5 135 305 4.5 0.1 4.9 4.4 06/19/2005 01:40:00 7.1 0.5 8.4 5.7 7 0.5 8 5.7 135 4 138 305 4.5 0.1 4.9 4.4 06/19/2005 01:50:00 6.3 0.7 7.6 4.2 6.3 0.6 8 4.6 134 5 138 305 4.4 0.1 4.9 4.4 06/19/2005 02:00:00 5.7 0.7 7.2 2.6 5.6 0.6 7.2 4.2 140 10 140 305 4.5 0.1 4.9 4.4 06/19/2005 02:10:00 5.2 1.4 8.4 2.3 5.4 1 8 3 154 9 150 305 4.5 0.2 4.9 4.4 06/19/2005 02:20:00 6.1 0.8 8 4.2 6.2 0.7 8 4.6 144 11 144 305 4.4 0.1 4.9 4.4 06/19/2005 02:30:00 5.5 0.9 7.6 3 5.5 0.8 6.8 3.4 129 12 134 305 4.4 0.1 4.9 4.4 06/19/2005 02:40:00 5 0.8 7.2 3.4 5.1 0.8 7.2 3 125 13 126 305 4.4 0.1 4.9 4.2 06/19/2005 02:50:00 4.6 1.1 7.6 1.9 4.6 1 7.6 2.3 124 12 130 305 4.4 0 4.7 4.2 06/19/2005 03:00:00 6.5 0.8 8.8 4.2 6.5 0.9 8.8 4.6 121 8 122 305 4.4 0.1 4.7 4.2 06/19/2005 03:10:00 7.2 1 9.1 4.6 7.2 0.9 9.9 5.3 127 9 135 305 4.4 0.1 4.7 4.2 06/19/2005 03:20:00 7.6 0.8 8.8 5.3 7.6 0.7 9.5 5.3 126 8 133 305 4.4 0.1 4.9 4.2 06/19/2005 03:30:00 7.8 1 10.3 4.9 7.9 1 9.9 5.3 129 9 132 305 4.4 0.1 4.9 4.2 06/19/2005 03:40:00 7.5 1.2 10.3 4.6 7.4 1.2 9.9 4.6 126 11 113 305 4.5 0.1 4.9 4.4 06/19/2005 03:50:00 6.6 1 9.1 3.8 6.4 1 9.1 3.8 118 9 112 305 4.5 0.1 4.9 4.4 06/19/2005 04:00:00 5.9 1 8.4 3.4 5.9 1 9.1 3.8 122 12 118 305 4.5 0.1 4.9 4.4 06/19/2005 04:10:00 6.2 1 9.9 4.2 6.3 1 9.9 4.6 126 12 126 305 4.5 0.1 4.9 4.4 06/19/2005 04:20:00 6.5 1 9.5 4.2 6.5 1 9.9 3.8 130 11 135 305 4.5 0.2 4.9 4.4 06/19/2005 04:30:00 7.2 0.6 9.1 5.3 7 0.6 8.8 5.3 135 4 147 305 4.5 0.1 4.9 4.4 06/19/2005 04:40:00 6.2 0.5 7.6 4.2 6.1 0.5 7.6 4.6 133 3 128 305 4.5 0.1 4.9 4.4 06/19/2005 04:50:00 5.4 0.5 6.5 3.8 5.3 0.5 6.5 3.8 135 4 136 305 4.5 0.1 4.9 4.4 06/19/2005 05:00:00 5.1 0.6 6.5 3.4 5.1 0.5 6.5 3.4 133 6 141 305 4.5 0.2 4.9 4.4 06/19/2005 05:10:00 4.3 0.7 5.7 2.3 4.5 0.6 6.5 3 125 9 134 305 4.5 0.2 4.9 4.4 06/19/2005 05:20:00 3.7 0.8 6.1 1.9 3.8 0.7 5.7 2.3 124 11 134 305 4.5 0.2 4.9 4.2 06/19/2005 05:30:00 4.6 0.7 6.5 2.6 4.7 0.7 6.8 3 121 10 131 305 4.4 0.2 4.9 4.4 06/19/2005 05:40:00 5.5 0.8 7.2 3 5.4 0.7 7.2 3.4 121 8 121 305 4.5 0.2 4.9 4.4 06/19/2005 05:50:00 4.9 1 6.8 2.3 5 1 7.6 2.3 113 12 131 305 4.5 0.1 4.9 4.4 06/19/2005 06:00:00 4.4 1 6.8 1.9 4.5 1 7.2 2.6 108 13 114 305 4.5 0.1 4.9 4.4 06/19/2005 06:10:00 5 1 7.6 1.9 4.9 0.8 7.2 2.3 119 17 128 305 4.7 0.1 5.2 4.4 06/19/2005 06:20:00 6.5 1 8.4 3.4 6.5 1 8.4 4.2 123 12 147 305 4.8 0 5.2 4.7 06/19/2005 06:30:00 6.7 1 8.8 4.6 6.8 1.1 9.5 4.6 127 11 125 305 4.7 0 5.2 4.7 06/19/2005 06:40:00 6 0.8 8 3.8 6 0.8 9.5 4.2 123 11 116 305 4.8 0 5.4 4.7 06/19/2005 06:50:00 6 1 9.5 3 6 1 9.1 3.4 125 12 132 305 5 0.1 5.4 4.9 06/19/2005 07:00:00 7.1 1.1 9.5 4.6 7.2 1.2 10.7 4.6 126 12 109 305 5 0.2 5.6 4.9 06/19/2005 07:10:00 6.9 0.9 9.5 4.6 6.9 0.9 9.5 4.9 128 11 135 305 5.2 0.1 5.6 4.9 06/19/2005 07:20:00 6.5 1 8.8 4.2 6.4 1 9.1 3.8 122 11 127 305 5.2 0.1 5.6 4.9 06/19/2005 07:30:00 7.1 1 9.5 4.2 7.1 0.9 9.9 4.6 124 11 117 305 5.3 0 5.9 4.9 06/19/2005 07:40:00 7.5 1.1 11.1 4.6 7.4 1.1 10.7 4.6 119 10 109 305 5.5 0 5.9 5.4 06/19/2005 07:50:00 7.9 1.1 10.7 4.9 7.8 1.1 10.7 4.9 121 10 114 305 5.5 0 5.9 5.4 06/19/2005 08:00:00 6.3 0.9 8.8 3.8 6.1 0.9 8.4 3.4 123 10 126 305 5.4 0 5.9 5.4 06/19/2005 08:10:00 5.4 0.9 8 3 5.4 0.8 8 3 127 12 108 305 5.5 0.1 6.1 5.4 06/19/2005 08:20:00 6.4 1.5 9.1 3 6.3 1.3 9.1 3.4 133 12 138 305 5.8 0 6.1 5.6 06/19/2005 08:30:00 7.1 1 10.3 4.9 6.9 1 9.5 4.9 135 10 144 305 6 0.1 6.4 5.9 06/19/2005 08:40:00 6.6 1 9.5 4.2 6.5 1 9.1 4.2 137 9 139 305 6.1 0.1 6.4 5.9 06/19/2005 08:50:00 6.5 1 8.4 3.8 6.5 0.9 8.8 3.8 134 10 123 305 6.2 0 6.4 5.9 06/19/2005 09:00:00 7.2 0.9 9.5 4.9 7.1 1 9.5 4.6 136 7 135 305 6.4 0 6.9 6.1 06/19/2005 09:10:00 6.4 1.1 10.3 3.8 6.5 1 9.5 4.2 136 9 124 305 6.7 0 6.9 6.4 06/19/2005 09:20:00 5.8 0.9 8 3.4 5.9 0.8 7.6 3.8 145 9 142 305 6.8 0 7.2 6.7 06/19/2005 09:30:00 5.7 1 8 3.4 5.7 0.9 8 3.8 143 8 150 305 6.6 0 6.9 6.4 06/19/2005 09:40:00 5 0.8 7.2 2.6 5.1 0.7 7.2 3.4 144 11 142 305 6.5 0 6.7 6.4 06/19/2005 09:50:00 5.1 0.9 7.6 2.3 5.3 0.9 7.6 3.4 150 12 134 305 6.5 0 6.7 6.4 06/19/2005 10:00:00 5.2 1.2 8 2.6 5.6 0.9 8.4 3.4 154 12 152 305 6.7 0 6.9 6.4 06/19/2005 10:10:00 4.7 1.2 7.2 2.3 5.2 1 7.6 2.6 159 14 142 305 6.7 0 6.9 6.7 06/19/2005 10:20:00 4.6 1 6.8 2.3 5.4 0.9 8 3 161 15 146 305 6.8 0 7.2 6.7 06/19/2005 10:30:00 5.6 1 8 2.6 5.6 0.9 8 3.4 144 10 146 305 7 0 7.2 6.9 06/19/2005 10:40:00 4.6 0.8 7.2 2.6 4.7 0.7 6.8 3 140 11 136 305 7.2 0 7.4 7.2 06/19/2005 10:50:00 5.2 0.7 6.8 3.4 5.4 0.6 6.8 3.4 143 9 145 305 7.2 0 7.4 7.2 06/19/2005 11:00:00 5 0.7 6.8 3 5.3 0.7 6.8 3.4 146 11 151 305 7.3 0 7.7 7.2 06/19/2005 11:10:00 5.1 0.7 7.2 3.4 5.3 0.6 6.8 3.8 143 10 140 305 7.5 0 7.7 7.4 06/19/2005 11:20:00 5.6 0.8 7.6 3.8 5.6 0.8 7.2 3.4 142 10 152 305 7.7 0 7.9 7.7 06/19/2005 11:30:00 5.8 1 8.8 3 6 0.9 8.8 3.4 144 10 149 305 8 0 8.2 7.7 06/19/2005 11:40:00 6.3 1 8.4 3.4 6.4 0.8 8.4 4.6 146 11 143 305 8.2 0 8.4 8.2 06/19/2005 11:50:00 6 0.8 8 3.4 6.1 0.7 7.6 3.8 149 9 151 305 8.2 0 8.4 7.9 06/19/2005 12:00:00 6.6 0.9 8.8 3.4 6.7 0.8 8.4 4.9 148 9 153 305 8.5 0.2 9.2 8.2 06/19/2005 12:10:00 5.9 1 8.4 3 6.1 0.9 8.4 3 150 11 144 305 9.1 0 9.7 8.9 06/19/2005 12:20:00 5.6 0.8 7.6 3 5.8 0.8 8.4 3 150 11 145 305 9.2 0 9.5 9.2 06/19/2005 12:30:00 5.8 0.7 7.2 3 5.9 0.7 7.2 3.8 139 9 141 305 8.8 0.1 9.2 8.7 06/19/2005 12:40:00 6.3 0.8 9.1 4.2 6.3 0.7 8.8 4.6 137 8 165 305 8.6 0 8.9 8.4 06/19/2005 12:50:00 6.2 0.8 8 3.8 6.3 0.8 8 4.2 138 9 140 305 8.6 0 8.7 8.4 06/19/2005 13:00:00 6.5 0.8 8.4 4.2 6.6 0.8 8.8 4.6 138 9 142 305 8.4 0 8.7 8.2 06/19/2005 13:10:00 4.7 1.8 8.8 1.9 4.8 2 8.4 1.9 188 36 138 305 7.7 0.5 8.4 7.2 06/19/2005 13:20:00 2.1 0.8 3.8 0.4 2.4 0.6 3.8 1.1 217 11 225 305 6.8 0.1 7.2 6.7 06/19/2005 13:30:00 3.1 1.6 6.5 0.4 3.3 1.5 7.2 0.4 166 29 152 305 7.2 0.3 7.9 6.9 06/19/2005 13:40:00 5 1 7.6 2.3 5.4 0.8 7.6 3 154 12 155 305 8.4 0 8.7 7.9 06/19/2005 13:50:00 5.2 1 7.2 2.3 5.4 0.7 7.6 3.4 148 13 149 305 8.5 0 8.7 8.2 06/19/2005 14:00:00 6.1 0.9 8 3.4 6.1 0.8 8 3.8 141 9 136 305 8.6 0 8.9 8.2 06/19/2005 14:10:00 6 0.8 8.8 3 6.1 0.7 8.8 4.2 139 9 144 305 8.7 0.1 9.2 8.4 06/19/2005 14:20:00 5.8 0.6 7.6 3.8 5.9 0.6 8 3.8 142 9 136 305 9.1 0 9.2 8.9 06/19/2005 14:30:00 5.6 1 8 2.6 5.7 0.8 8 3 145 13 156 305 9.3 0 9.7 9.2 06/19/2005 14:40:00 5.9 0.9 8.4 3.8 6 0.8 8.4 3.8 144 11 143 305 8.9 0.1 9.5 8.7 06/19/2005 14:50:00 6 0.8 8 3.8 6 0.8 7.6 4.2 141 10 146 305 8.8 0 9.2 8.4 06/19/2005 15:00:00 6.2 0.7 8 3.8 6.3 0.7 7.6 4.2 143 10 146 305 8.8 0 9.2 8.7 06/19/2005 15:10:00 6 0.9 8 3.8 6.1 0.8 7.6 4.2 145 9 151 305 8.6 0 8.9 8.4 06/19/2005 15:20:00 6.2 0.9 8 3.4 6.2 0.8 8.4 4.2 151 9 151 305 8.7 0 8.9 8.4 06/19/2005 15:30:00 6.1 1 8.4 3.4 6.2 0.9 8 3.4 145 10 150 305 8.8 0 9.2 8.7 06/19/2005 15:40:00 6.5 1 9.5 4.2 6.5 0.8 8.4 3.8 141 13 161 305 8.9 0 9.2 8.9 06/19/2005 15:50:00 5.5 1.2 8.4 3 6.5 1.1 9.1 3.8 165 15 171 305 9.2 0.1 9.5 8.9 06/19/2005 16:00:00 5.8 1.3 9.5 3 7.1 1.2 9.9 3.8 164 11 159 305 9.1 0 9.5 8.9 06/19/2005 16:10:00 5.8 1.2 8.8 3.4 6.3 0.9 9.1 4.2 155 13 147 305 9.2 0 9.5 9.2 06/19/2005 16:20:00 7 1.3 9.9 3.4 7.6 1.2 10.3 4.6 156 15 146 305 9.1 0 9.5 8.9 06/19/2005 16:30:00 7.1 1.6 11.1 3.8 8.6 1 12.2 6.1 167 15 140 305 9.1 0 9.2 8.9 06/19/2005 16:40:00 6.5 1.2 9.9 3.8 8.4 1.2 11.5 5.7 173 8 183 305 8.9 0.1 9.2 8.7 06/19/2005 16:50:00 6.4 1.2 10.7 3.8 7.9 1.2 10.3 4.6 168 11 152 305 9.1 0.2 9.5 8.9 06/19/2005 17:00:00 6.5 1.4 10.7 3 7.8 1.4 11.5 3.8 170 13 158 305 9.1 0 9.5 8.9 06/19/2005 17:10:00 6.6 1.7 11.1 3.4 8 1.4 11.8 4.9 177 10 190 305 9.1 0 9.7 8.9 06/19/2005 17:20:00 7.1 1.3 10.7 4.2 9 1 11.1 6.5 176 8 186 305 8.8 0 9.2 8.4 06/19/2005 17:30:00 6.8 1.1 9.9 4.2 9 1 11.8 5.7 175 7 184 305 8.4 0 8.7 8.2 06/19/2005 17:40:00 6.7 1.4 9.9 3.4 7.9 1.3 11.5 4.6 167 11 162 305 8.3 0 8.4 8.2 06/19/2005 17:50:00 6.8 1.4 10.7 3.8 7.8 1.3 11.1 4.6 167 12 186 305 8.4 0 8.4 8.2 06/19/2005 18:00:00 6.6 1.3 11.1 3 7.9 1.1 11.1 4.9 169 12 156 305 8.2 0 8.4 8.2 06/19/2005 18:10:00 6.8 1.4 10.7 3.4 7.9 1.3 11.1 4.6 168 11 169 305 8.4 0 8.4 8.2 06/19/2005 18:20:00 6.3 1.2 9.5 3.8 7.4 1 10.3 4.9 166 12 156 305 8.4 0 8.4 8.2 06/19/2005 18:30:00 6.2 1.1 9.5 3.8 6.9 1 10.7 4.2 162 11 137 305 8.2 0 8.7 8.2 06/19/2005 18:40:00 6.6 1.6 10.3 2.6 7.3 1.1 10.3 4.6 159 15 161 305 8.2 0 8.4 8.2 06/19/2005 18:50:00 6.5 1.3 10.3 3.8 7.5 1 10.7 4.6 162 15 159 305 8.1 0 8.2 7.9 06/19/2005 19:00:00 6.3 1.4 10.3 3.8 6.9 1.1 9.9 4.2 160 13 165 305 8 0 8.2 7.9 06/19/2005 19:10:00 6.6 1.5 10.7 2.6 7.4 1.1 10.3 4.2 162 14 149 305 7.8 0 8.2 7.7 06/19/2005 19:20:00 6.3 1.2 8.8 3.4 6.8 0.9 9.1 4.2 157 14 156 305 7.9 0 8.4 7.7 06/19/2005 19:30:00 6.7 1.5 10.7 3.4 7.2 1.2 10.7 3.8 159 14 148 305 7.7 0 7.9 7.7 06/19/2005 19:40:00 7.7 1.7 11.8 4.2 8 1.3 11.8 4.6 155 13 140 305 7.5 0 7.7 7.4 06/19/2005 19:50:00 7.3 1.5 11.5 4.2 8 1.1 11.5 5.3 159 13 146 305 7.2 0.1 7.4 7.2 06/19/2005 20:00:00 8.2 1.5 11.5 3.8 8.4 1.2 11.8 5.7 152 12 156 305 6.9 0 7.2 6.7 06/19/2005 20:10:00 9.1 1.2 12.2 6.1 8.9 1.1 11.8 6.1 150 9 161 305 6.7 0.1 6.9 6.4 06/19/2005 20:20:00 7.1 1.7 11.5 3.8 7.4 1.4 11.5 4.2 156 15 152 305 6.5 0 6.7 6.4 06/19/2005 20:30:00 7.6 1.3 11.5 4.2 7.7 1 11.1 5.3 154 10 157 305 6.4 0 6.7 6.1 06/19/2005 20:40:00 7.8 1.4 11.1 4.2 7.8 1.2 11.1 4.2 152 10 142 305 6.2 0 6.4 6.1 06/19/2005 20:50:00 8.6 1.4 12.2 4.2 8.6 1.2 11.8 5.7 152 9 152 305 6.1 0 6.1 5.9 06/19/2005 21:00:00 8.1 1.5 11.5 4.6 8.1 1.2 10.7 4.9 152 10 148 305 6 0 6.1 5.9 06/19/2005 21:10:00 9.5 1.6 12.6 4.6 9.4 1.4 13 6.1 150 8 155 305 5.9 0 5.9 5.9 06/19/2005 21:20:00 9.4 1.1 12.2 6.5 9.2 0.9 11.8 6.8 149 8 155 305 5.8 0 5.9 5.6 06/19/2005 21:30:00 8.7 1.2 11.8 6.1 8.7 1 11.5 6.1 150 8 138 305 5.7 0 5.9 5.6 06/19/2005 21:40:00 8.8 1 11.5 5.3 8.5 1 10.7 5.7 148 7 148 305 5.6 0 5.9 5.6 06/19/2005 21:50:00 7.7 1.3 10.7 4.2 7.6 1.2 11.1 3.8 150 9 137 305 5.6 0 5.9 5.6 06/19/2005 22:00:00 7 1.5 10.7 3.4 7 1.2 10.7 3.4 151 12 152 305 5.6 0 5.9 5.6 06/19/2005 22:10:00 8.1 1.7 13 4.2 8.1 1.7 13 4.2 144 12 141 305 5.6 0 5.9 5.4 06/19/2005 22:20:00 9.4 1.2 13.3 6.8 9.4 1.1 12.6 7.2 141 9 138 305 5.5 0 5.9 5.4 06/19/2005 22:30:00 8.6 1.1 11.8 5.7 8.6 1.1 11.8 6.1 145 9 132 305 5.5 0 5.6 5.4 06/19/2005 22:40:00 9.2 1.2 11.8 6.1 8.9 1.2 11.8 6.5 148 8 149 305 5.4 0 5.6 5.4 06/19/2005 22:50:00 7.8 1.7 11.8 3.8 8 1.3 11.8 4.9 153 12 145 305 5.4 0 5.6 5.4 06/19/2005 23:00:00 6.1 1.6 9.9 3 6.9 1.3 10.7 3.8 160 13 143 305 5.4 0 5.6 5.2 06/19/2005 23:10:00 6.6 1.3 9.9 3.4 7.4 1.1 10.7 5.3 160 13 160 305 5.3 0 5.6 5.2 06/19/2005 23:20:00 7 1.4 11.1 3.4 7.5 1.1 10.3 4.6 157 11 155 305 5.3 0 5.6 5.2 06/19/2005 23:30:00 6.5 1.5 10.3 3.4 6.8 1.3 10.7 4.2 153 11 140 305 5.3 0 5.6 5.2 06/19/2005 23:40:00 7.5 1.2 9.9 3.8 7.4 1 9.9 5.3 149 10 141 305 5.2 0 5.4 4.9 06/19/2005 23:50:00 8.3 1.1 11.5 4.9 8.2 1 10.7 5.7 148 9 154 305 5.2 0 5.6 4.9 06/20/2005 00:00:00 8 1.4 11.1 3.8 8 1.1 11.1 5.3 149 9 150 305 5.2 0 5.6 4.9 06/20/2005 00:10:00 6.8 1.3 10.3 3.8 6.9 1 9.9 4.6 152 11 168 305 5.2 0 5.6 5.2 06/20/2005 00:20:00 6.2 1.3 9.5 3 7 1.1 10.7 4.2 160 13 156 305 5.3 0 5.6 5.2 06/20/2005 00:30:00 6.5 1.5 11.5 3 7.1 1.1 10.7 4.6 157 11 147 305 5.3 0 5.6 5.2 06/20/2005 00:40:00 7.7 1.5 11.5 3.8 7.8 1.2 10.7 5.3 151 10 134 305 5.3 0 5.6 5.2 06/20/2005 00:50:00 8.6 1.3 11.5 5.7 8.6 1.1 11.8 6.1 150 9 146 305 5.2 0 5.6 4.9 06/20/2005 01:00:00 9.6 1 12.2 6.1 9.4 1 11.8 6.8 150 7 152 305 5.2 0 5.4 4.9 06/20/2005 01:10:00 8.5 1.5 11.8 4.6 8.6 1.3 11.8 5.7 152 9 156 305 5.1 0 5.4 4.9 06/20/2005 01:20:00 8.6 1.3 11.5 5.3 8.5 1.1 11.1 4.9 151 7 152 305 5.1 0.1 5.4 4.9 06/20/2005 01:30:00 8.5 1.2 11.1 5.3 8.4 1.1 11.1 5.7 150 9 152 305 5 0.1 5.4 4.9 06/20/2005 01:40:00 9 1.1 11.5 6.1 8.8 0.9 10.7 6.5 150 8 144 305 5 0.1 5.4 4.9 06/20/2005 01:50:00 8.9 1.2 11.8 5.7 8.7 1 11.1 6.5 150 8 155 305 5 0.1 5.4 4.9 06/20/2005 02:00:00 8.7 1.5 11.5 3.8 8.7 1 11.5 5.7 150 8 145 305 5.1 0.1 5.4 4.9 06/20/2005 02:10:00 8.4 1.4 11.5 4.9 8.5 1.1 11.1 5.7 150 9 150 305 5.1 0 5.4 4.9 06/20/2005 02:20:00 7.6 1.4 11.5 4.2 8 1.1 11.5 5.7 152 11 138 305 5.2 0 5.4 4.9 06/20/2005 02:30:00 9.1 1.4 11.8 3.8 9 1.1 11.5 6.1 150 8 149 305 5.1 0 5.4 4.9 06/20/2005 02:40:00 7.7 1.5 11.5 3.8 8.1 1 11.1 6.1 153 10 155 305 5.2 0 5.6 4.9 06/20/2005 02:50:00 7.9 1.4 11.5 4.2 8.2 1.1 11.1 5.7 153 9 147 305 5.2 0 5.6 4.9 06/20/2005 03:00:00 7.5 1.5 10.7 4.2 7.8 1 10.3 4.9 154 9 137 305 5.2 0.1 5.4 4.9 06/20/2005 03:10:00 7.7 1.5 11.1 4.2 7.9 1.1 11.1 4.9 153 10 152 305 5.1 0.1 5.4 4.9 06/20/2005 03:20:00 8.5 1.7 11.8 4.2 8.7 1.2 11.8 5.7 153 7 154 305 5.1 0.1 5.4 4.9 06/20/2005 03:30:00 7.8 1.5 11.5 3.8 8.2 1 11.5 5.7 154 8 160 305 5.1 0.1 5.4 4.9 06/20/2005 03:40:00 7.2 1.5 10.7 3.8 8.1 1 12.6 5.3 158 9 157 305 5 0.1 5.4 4.9 06/20/2005 03:50:00 6.8 1.2 10.3 3.8 7.4 0.9 10.3 4.9 157 9 153 305 5 0.1 5.4 4.9 06/20/2005 04:00:00 6.9 1.3 9.9 3.8 7.3 1 9.9 4.9 155 9 151 305 4.9 0.1 5.4 4.9 06/20/2005 04:10:00 6.7 1.3 9.9 3.8 7.3 1 10.3 4.6 157 10 153 305 5 0.1 5.4 4.9 06/20/2005 04:20:00 7.6 1 9.9 4.6 7.6 0.8 10.3 5.7 151 7 149 305 5 0.1 5.4 4.9 06/20/2005 04:30:00 7.2 1.2 9.9 3.8 7.3 0.9 9.9 5.3 151 8 148 305 5 0.1 5.4 4.9 06/20/2005 04:40:00 7.5 1 9.9 4.2 7.4 0.9 9.9 5.3 150 8 148 305 4.9 0.1 5.4 4.9 06/20/2005 04:50:00 7 1.1 9.5 3.8 7.1 0.8 9.5 5.3 151 9 151 305 4.9 0.1 5.4 4.9 06/20/2005 05:00:00 8 1 10.3 4.6 7.8 0.9 9.9 5.7 150 6 154 305 5 0.1 5.4 4.9 06/20/2005 05:10:00 7.4 1 10.3 4.9 7.2 1 9.5 4.9 147 8 148 305 5 0.1 5.4 4.9 06/20/2005 05:20:00 7.2 1 9.5 4.6 7.1 0.9 9.1 5.3 145 8 156 305 4.9 0.1 5.4 4.7 06/20/2005 05:30:00 7.6 1 10.7 4.9 7.3 0.9 10.3 5.3 146 8 149 305 4.9 0 5.4 4.7 06/20/2005 05:40:00 7.2 1 9.5 4.6 7.2 0.9 9.1 5.3 141 8 144 305 4.8 0 5.4 4.7 06/20/2005 05:50:00 6.9 1 9.5 4.6 6.8 0.8 9.1 4.6 144 9 146 305 4.9 0.1 5.4 4.7 06/20/2005 06:00:00 6.9 0.9 9.1 4.2 6.9 0.8 9.1 4.9 146 9 145 305 4.9 0.1 5.4 4.7 06/20/2005 06:10:00 6.9 0.9 9.5 4.2 7 0.9 9.1 4.6 142 9 142 305 4.9 0.1 5.4 4.9 06/20/2005 06:20:00 7.6 0.9 9.5 5.3 7.5 0.9 9.5 5.3 143 9 147 305 4.9 0.1 5.4 4.7 06/20/2005 06:30:00 8 0.9 11.1 5.7 7.9 0.8 9.9 6.1 145 8 141 305 4.9 0.1 5.4 4.9 06/20/2005 06:40:00 7.5 1.3 10.7 3.8 7.4 1.1 9.9 4.9 150 9 150 305 5 0.2 5.4 4.9 06/20/2005 06:50:00 6.4 1.2 9.5 3.4 6.8 1.1 9.1 4.2 153 11 146 305 5 0.1 5.6 4.9 06/20/2005 07:00:00 5.1 1.5 9.1 1.9 5.5 1.1 8.8 3.4 151 14 137 305 5.1 0.1 5.6 4.9 06/20/2005 07:10:00 4.9 1.3 8 1.9 5.5 1 8 3.4 155 13 150 305 5.2 0.1 5.6 4.9 06/20/2005 07:20:00 5.4 1.2 8 2.6 5.7 1 8 3 153 12 153 305 5.2 0.1 5.6 4.9 06/20/2005 07:30:00 5 1 7.6 2.6 5.7 0.9 7.6 3.4 157 10 153 305 5.2 0 5.6 4.9 06/20/2005 07:40:00 5 1.1 8 2.6 5.9 0.9 8.4 4.2 160 9 149 305 5.3 0 5.6 5.2 06/20/2005 07:50:00 4.4 1.2 7.2 2.3 5.1 0.9 7.2 3 158 10 151 305 5.4 0 5.9 5.4 06/20/2005 08:00:00 5 1.3 7.6 1.9 5.4 1.1 8 3 154 11 152 305 5.5 0 5.9 5.4 06/20/2005 08:10:00 6.1 1 8.4 3 6.3 0.8 8.4 3.8 150 8 147 305 5.4 0 5.9 5.4 06/20/2005 08:20:00 5.8 1.2 8 2.6 6.1 0.9 8 3.8 154 8 163 305 5.5 0.1 5.9 5.4 06/20/2005 08:30:00 5.3 1.3 8 2.3 5.7 1 7.6 3.4 154 9 152 305 5.6 0.1 5.9 5.4 06/20/2005 08:40:00 4.9 1.1 7.6 2.6 5.9 0.8 7.6 3.8 160 8 147 305 5.6 0.1 5.9 5.4 06/20/2005 08:50:00 4.1 0.8 6.5 2.3 5.2 0.7 7.2 3.4 163 10 163 305 5.7 0 5.9 5.6 06/20/2005 09:00:00 4 0.9 6.5 1.5 5.1 0.7 7.2 3.4 166 10 147 305 5.8 0 6.1 5.6 06/20/2005 09:10:00 3.5 0.8 5.7 1.9 4.4 0.6 6.1 2.6 164 12 159 305 5.9 0 6.1 5.6 06/20/2005 09:20:00 3.4 0.9 6.1 1.1 4.6 1.1 7.2 2.3 168 12 163 305 5.8 0 6.1 5.6 06/20/2005 09:30:00 3.7 0.7 5.7 1.9 5.1 0.7 6.8 3.4 166 10 156 305 5.8 0 6.1 5.6 06/20/2005 09:40:00 3.8 0.9 6.5 1.1 4.8 0.8 7.6 2.3 167 10 167 305 5.8 0 6.1 5.6 06/20/2005 09:50:00 4.4 0.9 7.2 2.6 6.3 0.8 8.4 4.6 170 8 182 305 6 0 6.4 5.9 06/20/2005 10:00:00 4 0.8 6.1 1.9 5.7 0.6 7.2 3.8 171 7 158 305 6.3 0 6.9 5.9 06/20/2005 10:10:00 4.3 0.8 6.5 2.3 5.4 0.6 6.8 3.4 172 10 159 305 6.5 0 6.9 6.1 06/20/2005 10:20:00 4.6 1.2 8.4 1.9 5.7 0.9 8 3.4 164 11 154 305 6.7 0 6.9 6.7 06/20/2005 10:30:00 4.7 1 7.6 2.6 5.1 0.8 7.2 3.4 154 12 150 305 6.7 0 7.2 6.7 06/20/2005 10:40:00 4.6 1.1 7.2 1.9 5 1 7.6 2.6 157 17 152 305 6.5 0 6.9 6.4 06/20/2005 10:50:00 4.9 1.2 7.6 2.3 5.4 1.2 8.4 2.3 159 14 145 305 6.5 0 6.9 6.4 06/20/2005 11:00:00 5.7 1.1 8.4 2.6 6 0.8 8.8 3.8 151 11 138 305 6.6 0 6.9 6.4 06/20/2005 11:10:00 5.7 1.1 8 2.6 5.9 1 8 3 153 11 151 305 6.6 0 6.9 6.4 06/20/2005 11:20:00 4.6 1 7.2 1.9 5 0.7 7.2 3.4 150 13 143 305 6.6 0 6.9 6.4 06/20/2005 11:30:00 4.8 1.2 8.4 1.5 4.9 1 7.2 1.9 151 12 155 305 6.5 0 6.9 6.4 06/20/2005 11:40:00 5.6 1.1 8.4 3 5.7 0.9 7.6 3.4 146 12 154 305 6.5 0 6.9 6.4 06/20/2005 11:50:00 4.9 1.3 7.6 2.3 5.2 1 7.6 3.4 153 11 151 305 6.8 0 7.2 6.4 06/20/2005 12:00:00 5.5 1.1 8.8 2.6 5.8 1 8.4 3.4 149 12 147 305 6.8 0 7.2 6.7 06/20/2005 12:10:00 5 1.1 8.4 2.6 5.1 1 8.4 3 147 12 151 305 7.1 0 7.4 6.9 06/20/2005 12:20:00 6.3 0.8 8.4 4.2 6.4 0.7 8 3.8 146 9 145 305 7.1 0 7.4 7.2 06/20/2005 12:30:00 5.4 1 8 3 5.5 1 7.6 3.4 146 11 147 305 7.2 0 7.4 7.2 06/20/2005 12:40:00 5.2 1 8 2.6 5.4 0.9 7.2 3.4 140 12 137 305 7.2 0 7.4 7.2 06/20/2005 12:50:00 5.1 0.8 7.2 2.3 5.3 0.7 7.6 3.8 145 13 156 305 7.2 0 7.4 7.2 06/20/2005 13:00:00 4.8 1.1 7.2 2.3 4.9 1 7.6 3 144 16 117 305 7.2 0.1 7.7 7.2 06/20/2005 13:10:00 5.9 1.2 9.1 2.6 6 1 9.9 4.2 144 13 129 305 7.7 0 7.9 7.4 06/20/2005 13:20:00 4.9 1.2 8 2.3 5.1 1.1 7.6 2.3 148 15 153 305 8 0 8.2 7.7 06/20/2005 13:30:00 6.4 1.1 9.1 3.4 6.4 1 8.8 4.2 141 12 165 305 8.1 0 8.2 7.9 06/20/2005 13:40:00 6.6 0.9 9.1 4.2 6.6 0.8 8.8 4.2 141 12 155 305 8.2 0 8.2 7.9 06/20/2005 13:50:00 6 1.4 9.1 1.9 6 1.3 8.8 2.3 147 12 139 305 8 0 8.2 7.7 06/20/2005 14:00:00 5.8 1.5 9.1 1.9 6 1.3 9.1 2.3 152 13 154 305 7.7 0 8.4 7.7 06/20/2005 14:10:00 5.1 1 8 2.6 5.5 1 8.4 3.4 159 12 143 305 8 0.1 8.2 7.7 06/20/2005 14:20:00 6 1.5 9.1 2.6 6.7 1.1 9.1 4.2 157 16 143 305 8 0 8.2 7.9 06/20/2005 14:30:00 6.2 1.2 8.8 3 7 1.1 9.5 3.4 162 13 140 305 8.2 0 8.4 7.9 06/20/2005 14:40:00 6 1.4 9.9 3.4 6.7 1 9.9 4.2 158 12 159 305 8.6 0 8.7 8.2 06/20/2005 14:50:00 6.1 1.3 9.5 3 6.6 1.1 9.9 4.2 162 13 154 305 8.1 0.2 8.7 7.7 06/20/2005 15:00:00 5.1 1.2 8.4 2.3 5.7 1 8.8 3.4 163 15 146 305 7.9 0 8.2 7.7 06/20/2005 15:10:00 5.4 1.3 8.8 2.6 5.8 1 9.1 3.4 154 15 151 305 8.2 0 8.4 7.9 06/20/2005 15:20:00 6.6 1.2 9.5 3.8 6.6 1 9.5 4.2 147 10 134 305 8.2 0 8.4 8.2 06/20/2005 15:30:00 6.2 1.2 9.1 3.4 6.2 1.1 8.8 4.2 143 10 137 305 8.3 0 8.7 8.2 06/20/2005 15:40:00 6.2 1.5 9.9 3.4 6.4 1.3 9.9 3.8 149 10 142 305 8.3 0.1 8.7 7.9 06/20/2005 15:50:00 6.5 1.3 9.1 2.3 6.6 1 9.1 3.4 150 11 147 305 8 0 8.2 7.9 06/20/2005 16:00:00 6.1 1.3 9.1 2.6 6.5 1 9.1 4.2 151 12 143 305 8.4 0.1 8.7 7.9 06/20/2005 16:10:00 6.7 1.2 9.9 3.8 6.9 1 9.5 4.6 149 13 154 305 8.5 0 8.7 8.2 06/20/2005 16:20:00 6 1 8.8 3.4 6.4 0.8 8.4 4.2 148 12 127 305 8.6 0 8.9 8.4 06/20/2005 16:30:00 5.1 1 8 3 5.4 1 8 3.4 149 15 152 305 8.7 0.1 8.9 8.2 06/20/2005 16:40:00 5.8 1.2 8.4 2.6 6 1.1 8.8 3 150 13 151 305 8.7 0 8.9 8.4 06/20/2005 16:50:00 6.8 1.4 9.9 3.4 7 1.2 9.5 4.6 152 11 161 305 8.7 0 9.2 8.4 06/20/2005 17:00:00 6 1.1 8.8 2.6 6.3 1 8.8 3.8 150 11 153 305 8.6 0 8.9 8.4 06/20/2005 17:10:00 5.7 1.2 8.4 3 6 1 8.8 3.8 151 15 136 305 8.4 0 8.9 8.2 06/20/2005 17:20:00 5.4 1 9.5 3 5.8 1 8.4 3.4 152 14 161 305 8.5 0 8.7 8.4 06/20/2005 17:30:00 5.7 1.3 9.5 2.3 6.1 1.1 9.1 3 149 11 148 305 8.3 0.1 8.9 8.2 06/20/2005 17:40:00 5.9 1.2 8.8 3 6.4 1 8.4 3.8 153 12 144 305 8 0 8.2 7.9 06/20/2005 17:50:00 5.8 1.2 8.8 3 6.2 1 8.4 3.8 153 12 151 305 7.9 0 8.2 7.7 06/20/2005 18:00:00 6.2 1 8.8 3 6.6 0.9 8.8 4.9 150 10 156 305 7.9 0 8.2 7.7 06/20/2005 18:10:00 5.7 0.9 8 3 5.9 0.9 8.4 3.8 148 9 151 305 7.9 0 8.2 7.9 06/20/2005 18:20:00 5.6 1 7.6 2.6 5.7 0.8 8 3.4 140 13 136 305 7.9 0 8.2 7.7 06/20/2005 18:30:00 5.6 1.3 8.4 2.3 5.7 1.3 8.8 2.6 145 11 151 305 7.6 0 7.9 7.4 06/20/2005 18:40:00 6.1 0.8 8 3.8 6.3 0.8 8 3.8 146 10 151 305 7.4 0 7.7 7.2 06/20/2005 18:50:00 6.6 0.8 8.4 4.9 6.8 0.7 8.4 5.3 149 8 154 305 7.4 0 7.7 7.2 06/20/2005 19:00:00 5.6 1.2 8.8 2.3 5.8 1.1 8.8 3.4 151 12 152 305 7.2 0 7.4 7.2 06/20/2005 19:10:00 5.2 1.2 7.6 2.6 5.5 0.9 8 3 151 12 142 305 7.1 0 7.4 7.2 06/20/2005 19:20:00 4.9 0.9 8 3 5 0.8 7.2 3 147 11 154 305 7.1 0 7.4 6.9 06/20/2005 19:30:00 4.6 1.1 7.2 1.5 4.8 0.8 6.5 2.6 150 12 147 305 7.2 0 7.4 7.2 06/20/2005 19:40:00 5.5 1.2 8.4 2.3 5.6 1 8.4 3.4 147 12 135 305 7 0 7.2 6.9 06/20/2005 19:50:00 6.5 1 8.8 3.4 6.5 0.8 8.4 4.2 149 8 161 305 6.7 0 6.9 6.4 06/20/2005 20:00:00 6.5 1 8.8 3.8 6.4 0.9 8.8 4.2 148 7 152 305 6.6 0 6.9 6.4 06/20/2005 20:10:00 6.7 0.8 8.8 4.6 6.7 0.8 8.4 4.9 143 9 158 305 6.6 0 6.9 6.4 06/20/2005 20:20:00 7.1 0.8 9.5 5.3 7 0.8 9.1 5.3 146 7 140 305 6.5 0 6.7 6.1 06/20/2005 20:30:00 7.3 0.9 9.1 4.9 7.1 0.8 9.1 4.9 149 8 152 305 6.3 0 6.4 6.1 06/20/2005 20:40:00 7.2 1 9.9 4.2 7.1 1 9.5 4.6 148 8 142 305 6.3 0 6.4 6.1 06/20/2005 20:50:00 7.4 0.9 9.5 4.9 7.3 0.8 9.5 5.3 148 7 154 305 6.1 0 6.4 6.1 06/20/2005 21:00:00 6.9 1.1 9.5 3.8 7 0.9 9.5 4.6 148 9 154 305 6.1 0 6.4 6.1 06/20/2005 21:10:00 6.9 1 9.1 3.8 7.1 0.9 9.1 4.9 149 9 153 305 6.2 0 6.4 6.1 06/20/2005 21:20:00 7.7 0.9 9.9 5.3 7.7 0.7 9.1 5.7 149 7 152 305 6.3 0 6.4 6.1 06/20/2005 21:30:00 6.5 1 8.8 3.8 6.5 0.8 8.4 4.2 149 10 150 305 6.3 0 6.4 6.1 06/20/2005 21:40:00 4.8 1 7.6 2.3 5.4 0.8 7.2 3 158 14 139 305 6.3 0 6.4 6.1 06/20/2005 21:50:00 5.6 1.3 9.1 2.3 5.8 1 9.1 3.8 152 12 145 305 6.3 0 6.4 6.1 06/20/2005 22:00:00 6.7 1 9.5 4.6 6.5 0.9 9.1 4.6 146 8 156 305 6.1 0 6.4 5.9 06/20/2005 22:10:00 6.4 1 9.1 4.2 6.4 0.9 9.1 3.8 143 9 134 305 6 0 6.1 5.9 06/20/2005 22:20:00 5.8 0.8 8 3.8 5.9 0.8 8 3.8 137 8 152 305 5.9 0 5.9 5.6 06/20/2005 22:30:00 5.3 0.8 7.2 3.4 5.4 0.7 6.8 3.8 139 9 139 305 5.8 0 5.9 5.6 06/20/2005 22:40:00 4.7 0.9 7.2 1.9 4.8 0.8 6.8 3 144 12 152 305 5.6 0 5.9 5.6 06/20/2005 22:50:00 5.3 1.1 8 2.3 5.4 0.9 7.6 3.4 149 9 152 305 5.6 0 5.9 5.4 06/20/2005 23:00:00 4.5 1.1 6.5 1.9 4.8 0.9 6.8 3 151 11 152 305 5.5 0 5.9 5.4 06/20/2005 23:10:00 4.1 1 6.1 1.5 4.3 0.7 6.1 2.6 149 11 150 305 5.5 0 5.9 5.4 06/20/2005 23:20:00 3.9 1 6.1 1.9 4.1 0.8 6.1 1.9 150 11 151 305 5.4 0 5.6 5.4 06/20/2005 23:30:00 3 0.8 5.3 1.1 3.3 0.7 5.7 2.3 147 13 142 305 5.4 0 5.6 5.4 06/20/2005 23:40:00 3 1 5.3 0.7 3.3 0.8 5.3 1.5 143 13 132 305 5.4 0 5.6 5.4 06/20/2005 23:50:00 4.5 0.7 6.1 2.6 4.5 0.6 5.7 3 137 8 131 305 5.4 0 5.6 5.4 06/21/2005 00:00:00 4 0.8 5.7 1.9 4.1 0.7 5.7 2.3 139 10 149 305 5.4 0 5.9 5.4 06/21/2005 00:10:00 3.4 0.8 6.1 1.5 3.6 0.6 5.7 2.3 143 12 145 305 5.4 0 5.6 5.4 06/21/2005 00:20:00 3.5 0.7 5.7 1.9 3.7 0.6 5.3 2.3 141 10 153 305 5.4 0 5.6 5.2 06/21/2005 00:30:00 2.8 0.9 4.6 0.7 3.2 0.7 4.9 1.5 133 12 145 305 5.4 0 5.6 5.2 06/21/2005 00:40:00 3.4 0.7 5.7 1.5 3.3 0.7 5.3 1.9 124 12 137 305 5.3 0 5.6 5.4 06/21/2005 00:50:00 3.5 0.8 5.3 1.5 3.6 0.7 5.3 2.3 129 12 122 305 5.4 0 5.6 5.2 06/21/2005 01:00:00 3.6 0.8 5.3 1.5 3.8 0.8 5.3 1.9 129 11 135 305 5.4 0 5.6 5.4 06/21/2005 01:10:00 3.6 0.8 5.7 1.5 3.7 0.7 5.7 2.3 122 9 120 305 5.4 0 5.6 5.2 06/21/2005 01:20:00 3.8 0.9 5.7 1.9 4 0.8 6.1 2.3 134 11 130 305 5.3 0 5.6 5.2 06/21/2005 01:30:00 4.4 0.6 6.1 2.6 4.5 0.6 6.1 3 134 8 148 305 5.3 0 5.6 5.2 06/21/2005 01:40:00 4.5 0.7 6.1 2.6 4.6 0.6 5.7 2.6 137 10 148 305 5.3 0 5.6 5.2 06/21/2005 01:50:00 3.7 0.8 5.7 1.9 3.8 0.7 6.1 2.3 136 12 151 305 5.3 0 5.6 5.2 06/21/2005 02:00:00 3.9 0.9 5.7 0.7 3.9 0.7 5.7 2.3 125 11 119 305 5.2 0 5.6 5.2 06/21/2005 02:10:00 3.6 0.6 4.9 2.3 3.8 0.5 5.3 2.6 130 14 124 305 5.3 0 5.6 5.2 06/21/2005 02:20:00 3.1 0.6 4.9 1.5 3.2 0.6 5.3 1.5 129 11 149 305 5.2 0 5.6 4.9 06/21/2005 02:30:00 3 1 5.7 0.7 3.2 0.8 5.7 1.5 129 12 123 305 5.3 0 5.6 5.2 06/21/2005 02:40:00 3.9 0.6 5.7 2.3 4 0.6 6.1 2.6 125 12 140 305 5.3 0 5.6 5.2 06/21/2005 02:50:00 4.2 0.8 6.1 1.9 4.3 0.7 6.1 2.6 121 12 121 305 5.3 0 5.6 5.2 06/21/2005 03:00:00 4 0.8 6.5 2.3 4.1 0.8 6.5 2.3 122 13 126 305 5.3 0 5.6 5.2 06/21/2005 03:10:00 2.6 1.1 5.3 0.4 2.9 0.8 5.3 1.5 103 24 108 305 5.3 0 5.6 5.2 06/21/2005 03:20:00 3.3 0.8 5.3 1.1 3.5 0.7 4.9 1.9 113 18 133 305 5.3 0 5.6 5.2 06/21/2005 03:30:00 3.7 0.7 5.3 1.9 3.8 0.6 5.3 2.3 119 11 130 305 5.4 0 5.9 5.2 06/21/2005 03:40:00 4 0.6 5.7 2.6 4.2 0.6 5.7 3 130 8 135 305 5.5 0 5.9 5.4 06/21/2005 03:50:00 4.8 0.6 6.1 2.6 4.9 0.6 6.1 2.6 133 8 136 305 5.5 0.1 5.9 5.4 06/21/2005 04:00:00 4.4 1 6.8 1.9 4.5 0.8 6.5 2.6 133 8 142 305 5.5 0.1 5.9 5.4 06/21/2005 04:10:00 3.6 0.7 5.3 1.1 3.8 0.6 4.9 2.3 123 11 124 305 5.5 0 5.9 5.4 06/21/2005 04:20:00 3.1 0.6 4.6 1.5 3.4 0.6 4.6 1.9 124 10 121 305 5.5 0 5.9 5.4 06/21/2005 04:30:00 2.9 0.7 4.6 1.1 3.2 0.6 4.6 1.5 123 9 123 305 5.5 0 5.9 5.4 06/21/2005 04:40:00 3 0.6 4.6 1.5 3.2 0.5 4.6 2.3 124 7 120 305 5.5 0.1 5.9 5.4 06/21/2005 04:50:00 3.1 0.5 4.6 1.9 3.3 0.4 4.6 2.6 118 7 119 305 5.5 0.1 5.9 5.4 06/21/2005 05:00:00 3.7 0.5 4.9 2.6 3.8 0.5 5.3 2.6 119 8 122 305 5.7 0 6.1 5.6 06/21/2005 05:10:00 3.6 0.7 5.3 1.5 3.8 0.7 5.7 2.3 120 12 116 305 5.7 0 6.1 5.6 06/21/2005 05:20:00 3.9 0.6 5.7 2.6 4 0.5 5.7 2.6 119 8 120 305 5.7 0 5.9 5.6 06/21/2005 05:30:00 3.5 0.7 4.9 1.1 3.6 0.6 5.3 2.3 118 11 106 305 5.7 0 6.1 5.6 06/21/2005 05:40:00 3.8 0.7 5.3 1.9 4 0.7 5.7 2.3 115 10 123 305 5.8 0 6.1 5.6 06/21/2005 05:50:00 4.3 0.8 6.1 2.3 4.4 0.7 6.1 3 117 8 117 305 5.7 0 6.1 5.6 06/21/2005 06:00:00 4.4 0.8 5.7 2.3 4.5 0.7 6.1 3 120 10 121 305 5.7 0 6.1 5.6 06/21/2005 06:10:00 4.5 0.6 6.1 2.3 4.6 0.6 6.1 3 122 9 131 305 5.6 0.1 5.9 5.6 06/21/2005 06:20:00 4.6 0.5 6.1 3 4.6 0.5 6.1 3 114 9 129 305 5.6 0.1 5.9 5.4 06/21/2005 06:30:00 4.6 0.4 5.7 3.4 4.6 0.4 6.1 3.4 107 7 112 305 5.6 0.1 5.9 5.4 06/21/2005 06:40:00 4 0.8 5.7 1.9 4 0.7 5.3 2.3 103 10 108 305 5.5 0.1 5.9 5.4 06/21/2005 06:50:00 3.2 0.7 4.9 1.5 3.3 0.6 5.3 1.9 95 13 91 305 5.5 0 5.9 5.4 06/21/2005 07:00:00 2.6 0.6 4.2 0.7 2.7 0.5 4.6 1.5 98 15 93 305 5.4 0 5.9 5.4 06/21/2005 07:10:00 3 0.5 4.2 1.9 3.1 0.5 4.6 1.9 88 12 78 305 5.4 0 5.9 5.4 06/21/2005 07:20:00 3 0.8 4.9 1.1 3 0.6 4.6 1.5 88 17 88 305 5.4 0 5.9 5.4 06/21/2005 07:30:00 2 0.7 3.8 0.4 2.3 0.5 3.8 0.7 80 16 63 305 5.4 0 5.9 5.4 06/21/2005 07:40:00 2.2 0.5 3.4 0.4 2.5 0.4 3.4 1.5 88 16 78 305 5.4 0 5.9 5.4 06/21/2005 07:50:00 2.4 0.5 3.8 1.1 2.6 0.4 4.2 1.5 97 13 110 305 5.5 0 5.9 5.4 06/21/2005 08:00:00 2.3 0.6 3.8 1.1 2.6 0.5 4.2 1.5 98 17 106 305 5.6 0.1 5.9 5.4 06/21/2005 08:10:00 1.5 0.8 4.2 0.4 2 0.5 3.4 0.7 105 19 131 305 5.8 0 6.1 5.6 06/21/2005 08:20:00 1.4 0.7 2.6 0.4 1.8 0.5 3.4 0.7 94 27 101 305 5.8 0 6.1 5.6 06/21/2005 08:30:00 1 0.6 3.4 0.4 1.5 0.5 3.4 0.4 76 26 118 305 5.8 0 6.1 5.6 06/21/2005 08:40:00 1.2 0.6 2.6 0.4 1.7 0.5 3 0.7 71 19 76 305 5.7 0 6.1 5.6 06/21/2005 08:50:00 1.4 0.7 3 0.4 2 0.5 3.4 1.1 69 19 60 305 5.6 0.2 5.9 4.9 06/21/2005 09:00:00 1.8 0.7 3 0.4 2.3 0.5 3.4 1.1 69 12 65 305 5.3 0 5.6 4.9 06/21/2005 09:10:00 1.7 0.6 3.4 0.4 2.1 0.5 3 0.7 83 17 120 305 5.6 0.2 6.1 5.4 06/21/2005 09:20:00 1.3 0.8 2.6 0.4 1.6 0.6 2.6 0.4 96 17 93 305 6 0 6.1 5.9 06/21/2005 09:30:00 1.1 0.6 2.6 0.4 1.4 0.6 2.6 0.4 89 24 77 305 6 0 6.1 5.6 06/21/2005 09:40:00 1 0.6 2.3 0.4 1.3 0.5 2.6 0.4 97 20 113 305 6 0 6.4 5.9 06/21/2005 09:50:00 1.7 0.6 3 0.4 1.8 0.5 3 0.4 120 11 131 305 6 0 6.4 5.9 06/21/2005 10:00:00 2.5 0.6 3.4 0.7 2.5 0.5 3.8 1.1 113 12 126 305 6.1 0.1 6.4 5.9 06/21/2005 10:10:00 2.5 0.6 3.8 1.1 2.8 0.5 3.8 1.5 119 9 121 305 6.3 0 6.4 6.1 06/21/2005 10:20:00 2 0.6 3 0.4 2.3 0.4 3.4 1.1 119 10 144 305 6.3 0 6.7 6.1 06/21/2005 10:30:00 0.6 0.4 2.3 0.4 1.1 0.5 2.3 0.4 92 22 119 305 6.5 0 6.7 6.1 06/21/2005 10:40:00 0.4 0.2 1.5 0.4 1.1 0.4 1.9 0.4 84 23 66 305 6.3 0 6.7 6.1 06/21/2005 10:50:00 1 0.5 2.3 0.4 1.6 0.4 2.6 0.7 79 15 108 305 6.3 0 6.4 6.1 06/21/2005 11:00:00 0.7 0.5 2.3 0.4 1.1 0.5 2.3 0.4 70 19 67 305 6.5 0 6.9 6.1 06/21/2005 11:10:00 0.6 0.4 1.9 0.4 1.2 0.4 2.3 0.4 88 22 75 305 6.8 0 7.2 6.4 06/21/2005 11:20:00 1 0.5 2.3 0.4 1.4 0.5 2.6 0.4 83 21 61 305 7 0 7.2 6.9 06/21/2005 11:30:00 1.6 0.5 2.6 0.4 1.9 0.5 3 0.7 82 17 71 305 7 0 7.2 6.9 06/21/2005 11:40:00 2.1 0.5 3.4 0.7 2.3 0.5 3.4 1.1 98 18 105 305 7.5 0.1 7.7 7.2 06/21/2005 11:50:00 3.2 0.6 4.9 1.1 3.2 0.6 4.9 1.9 89 10 82 305 7.7 0 7.9 7.7 06/21/2005 12:00:00 3.9 0.5 5.3 2.6 3.9 0.5 5.3 2.3 89 11 81 305 7.6 0 7.9 7.7 06/21/2005 12:10:00 4 0.4 4.9 3 4 0.4 5.3 3 91 9 99 305 7.5 0 7.7 7.4 06/21/2005 12:20:00 3.7 0.4 4.6 2.6 3.7 0.3 4.6 2.6 85 6 72 305 7.5 0 7.7 7.4 06/21/2005 12:30:00 3.7 0.4 4.6 2.6 3.7 0.3 4.2 3 83 5 87 305 6.8 0.5 7.7 6.1 06/21/2005 12:40:00 3.5 0.5 4.9 2.6 3.4 0.4 4.6 2.6 79 5 71 305 6.3 0.2 6.7 5.9 06/21/2005 12:50:00 2.7 0.3 3.4 1.9 3 0.2 3.4 2.6 65 8 72 305 5.9 0 6.1 5.9 06/21/2005 13:00:00 3.1 0.3 3.8 2.3 3.3 0.3 4.2 2.6 58 5 56 305 5.8 0 6.1 5.6 06/21/2005 13:10:00 3.6 0.3 4.2 3 3.8 0.2 4.2 3 57 5 50 305 5.9 0.1 6.1 5.6 06/21/2005 13:20:00 3.7 0.2 4.2 3.4 3.9 0.2 4.2 3.4 51 4 54 305 6.3 0.1 6.7 5.9 06/21/2005 13:30:00 4.1 0.3 4.6 3.4 4.3 0.3 4.9 3.8 46 2 44 305 6.8 0 7.2 6.4 06/21/2005 13:40:00 5.2 0.3 6.1 4.6 5.3 0.4 6.1 4.6 50 3 54 305 6.7 0.1 7.2 6.4 06/21/2005 13:50:00 5.2 0.3 6.1 4.2 5.1 0.3 5.7 3.8 54 6 62 305 6.7 0 6.9 6.4 06/21/2005 14:00:00 5.3 0.6 6.8 3.4 5 0.6 6.8 3.4 63 9 62 305 7 0.2 7.7 6.9 06/21/2005 14:10:00 5.6 0.6 7.6 4.2 5.4 0.6 7.2 3.8 75 11 86 305 8.1 0.2 8.4 7.7 06/21/2005 14:20:00 6.2 0.8 8 3.8 5.9 0.8 8 3.8 83 8 85 305 8.4 0.1 8.7 8.2 06/21/2005 14:30:00 7.2 0.7 8.8 4.9 6.9 0.7 8.4 4.6 87 6 77 305 8.8 0 9.2 8.4 06/21/2005 14:40:00 7.2 0.6 8.8 5.3 6.9 0.6 8.4 4.9 88 6 86 305 9.2 0.1 9.5 8.9 06/21/2005 14:50:00 7 0.5 8 5.3 6.8 0.5 8 5.3 89 6 90 305 9.4 0.1 10 9.2 06/21/2005 15:00:00 6.9 0.6 8.8 5.3 6.7 0.6 8.4 4.9 88 6 92 305 9.3 0.1 10 9.2 06/21/2005 15:10:00 6.7 0.6 8 4.9 6.5 0.6 8.4 4.6 85 7 87 305 9.5 0 10 9.5 06/21/2005 15:20:00 6.6 0.6 8 5.3 6.4 0.6 7.6 4.9 82 7 87 305 9.7 0 10 9.5 06/21/2005 15:30:00 6.5 0.7 8 4.6 6.2 0.7 7.6 4.2 76 9 75 305 9.5 0.2 10.2 9.2 06/21/2005 15:40:00 6.5 0.8 8.4 4.2 6.2 0.8 8 3.8 77 8 76 305 9.7 0 10.2 9.5 06/21/2005 15:50:00 5.8 0.8 7.6 3.8 5.6 0.8 7.2 3.8 59 15 76 305 8.8 0.6 10.2 7.7 06/21/2005 16:00:00 6 0.7 7.2 4.2 5.7 0.7 7.6 3.4 50 15 65 305 8.2 0.3 8.9 7.7 06/21/2005 16:10:00 6.7 0.4 7.6 5.7 6.6 0.4 7.6 5.3 39 5 35 305 7.3 0.1 7.9 7.2 06/21/2005 16:20:00 6.8 0.4 7.6 5.7 6.8 0.4 8 5.7 38 5 35 305 7.3 0 7.7 7.2 06/21/2005 16:30:00 6.4 0.8 8.4 3.8 6.2 0.8 8 3 61 15 70 305 8.2 0.7 10 7.4 06/21/2005 16:40:00 6.9 0.9 8.8 4.6 6.6 0.8 8.4 4.6 76 8 84 305 9.5 0.2 10 9.2 06/21/2005 16:50:00 6.9 0.7 9.1 5.3 6.5 0.7 8 4.6 76 7 80 305 9.8 0.1 10.5 9.2 06/21/2005 17:00:00 7.3 0.6 9.1 5.7 7 0.6 8.8 5.3 73 8 75 305 9.9 0.2 10.8 9.5 06/21/2005 17:10:00 8.1 0.5 9.1 6.5 8 0.6 9.1 6.5 68 6 73 305 9.5 0.1 10 9.2 06/21/2005 17:20:00 8.1 0.6 9.5 5.7 7.8 0.7 9.5 6.1 70 7 72 305 9.7 0.1 10 9.5 06/21/2005 17:30:00 7.9 0.7 9.5 6.1 7.7 0.7 9.1 4.9 66 7 66 305 9.9 0 10.2 9.7 06/21/2005 17:40:00 7 0.6 9.1 5.7 7 0.6 9.1 5.3 61 6 62 305 8.7 0.6 10 7.7 06/21/2005 17:50:00 7 0.4 8.4 5.7 7.1 0.4 8 5.7 51 5 56 305 7.5 0.1 7.9 7.2 06/21/2005 18:00:00 6.7 0.3 8 6.1 6.8 0.3 7.6 5.7 49 3 55 305 7.3 0 7.7 7.2 06/21/2005 18:10:00 7.2 0.3 8 6.5 7.2 0.4 8.4 6.1 56 3 56 305 7.6 0 7.9 7.4 06/21/2005 18:20:00 7.5 0.5 8.8 6.1 7.5 0.5 8.4 5.3 58 4 62 305 7.7 0 7.9 7.4 06/21/2005 18:30:00 7.7 0.4 8.4 6.8 7.6 0.5 8.8 6.1 61 4 59 305 7.7 0.1 7.9 7.4 06/21/2005 18:40:00 7.4 0.3 8 6.1 7.4 0.4 8.4 5.7 56 3 55 305 7.5 0 7.9 7.4 06/21/2005 18:50:00 7.1 0.4 8 5.7 7 0.5 8.4 5.7 54 3 51 305 7.2 0.1 7.7 6.9 06/21/2005 19:00:00 6.5 0.4 7.6 4.9 6.4 0.5 8 4.9 52 4 51 305 7 0 7.7 6.9 06/21/2005 19:10:00 7.2 0.3 8 6.5 7.3 0.4 8.4 6.1 54 3 56 305 7 0 7.2 6.9 06/21/2005 19:20:00 7.4 0.4 8.4 6.5 7.4 0.4 8.4 6.1 55 2 54 305 7 0 7.4 6.9 06/21/2005 19:30:00 7.3 0.3 8.4 6.5 7.4 0.4 8.4 5.7 53 3 52 305 7 0.1 7.7 6.9 06/21/2005 19:40:00 7.4 0.4 8.4 6.5 7.6 0.4 8.4 6.5 54 3 57 305 7 0 7.7 6.9 06/21/2005 19:50:00 7.7 0.4 8.8 6.8 7.7 0.4 8.8 6.5 55 3 53 305 7 0 7.7 6.9 06/21/2005 20:00:00 7.7 0.3 8.8 6.8 7.8 0.3 8.8 7.2 54 3 52 305 7 0 7.7 6.9 06/21/2005 20:10:00 7.4 0.4 8.4 6.5 7.5 0.4 8.8 6.5 54 3 56 305 7 0 7.7 6.9 06/21/2005 20:20:00 7.3 0.4 8.4 6.1 7.4 0.4 8.4 6.1 54 3 57 305 6.8 0 7.4 6.7 06/21/2005 20:30:00 7.5 0.4 8.4 6.5 7.6 0.4 8.8 6.5 54 3 53 305 6.7 0.1 7.2 6.4 06/21/2005 20:40:00 7.4 0.4 8.8 6.5 7.6 0.4 8.4 6.5 55 3 57 305 6.6 0.1 7.2 6.4 06/21/2005 20:50:00 7.3 0.5 8.4 5.7 7.5 0.5 8.8 5.7 58 4 57 305 6.7 0.1 7.2 6.4 06/21/2005 21:00:00 7.4 0.4 8.4 6.1 7.6 0.4 8.8 6.5 58 4 64 305 6.6 0 7.2 6.4 06/21/2005 21:10:00 7.3 0.4 8.4 6.5 7.5 0.4 8.4 6.5 57 3 56 305 6.3 0 6.9 6.1 06/21/2005 21:20:00 7.2 0.4 8 6.1 7.5 0.4 8.4 6.1 56 4 54 305 6.5 0 6.9 6.4 06/21/2005 21:30:00 7.1 0.3 8 6.1 7.4 0.3 8 6.1 56 3 62 305 6.5 0 7.2 6.1 06/21/2005 21:40:00 7.1 0.3 8 6.1 7.2 0.3 8 6.1 54 3 58 305 6.4 0 7.2 6.1 06/21/2005 21:50:00 7 0.3 7.6 6.1 7.1 0.3 8 6.5 54 2 55 305 6.3 0 6.9 6.1 06/21/2005 22:00:00 7.2 0.3 8 6.5 7.4 0.3 8 6.5 57 3 59 305 6.3 0 6.9 6.1 06/21/2005 22:10:00 7.3 0.3 8 6.5 7.5 0.3 8 6.8 57 3 58 305 6.2 0 6.7 6.1 06/21/2005 22:20:00 7.1 0.3 8 6.5 7.3 0.3 8 6.5 55 3 55 305 6.1 0 6.4 5.9 06/21/2005 22:30:00 7 0.4 8 6.1 7.1 0.4 8 6.1 53 3 52 305 6.1 0 6.1 5.9 06/21/2005 22:40:00 6.9 0.3 7.6 6.1 7 0.3 8 6.5 53 3 54 305 6 0 6.1 5.9 06/21/2005 22:50:00 6.9 0.4 8 6.1 7.1 0.4 8.4 6.1 53 3 54 305 6 0 6.1 5.9 06/21/2005 23:00:00 7.1 0.3 8 6.1 7.3 0.3 8 6.5 56 3 54 305 5.9 0 5.9 5.9 06/21/2005 23:10:00 7.1 0.3 7.6 6.1 7.3 0.3 8 6.5 58 3 55 305 5.9 0 5.9 5.9 06/21/2005 23:20:00 6.3 0.5 8 4.9 6.5 0.6 8 4.9 62 5 62 305 6.1 0.1 6.4 5.9 06/21/2005 23:30:00 5.7 0.5 7.2 4.6 5.7 0.4 7.2 4.6 67 6 67 305 6.7 0 6.9 6.4 06/21/2005 23:40:00 6.4 0.5 7.6 4.6 6.4 0.6 7.6 4.6 63 5 65 305 6.5 0.2 6.9 5.9 06/21/2005 23:50:00 6.6 0.3 7.2 5.7 6.8 0.3 7.6 6.1 59 3 56 305 6 0 6.1 5.9 06/22/2005 00:00:00 6.4 0.3 6.8 5.7 6.7 0.3 7.2 5.7 55 4 57 305 5.9 0 6.4 5.6 06/22/2005 00:10:00 6 0.3 7.2 4.9 6.2 0.3 6.8 5.3 52 3 46 305 5.6 0 5.9 5.4 06/22/2005 00:20:00 6 0.3 6.8 4.9 6.3 0.3 6.8 5.7 52 2 53 305 5.5 0 5.6 5.4 06/22/2005 00:30:00 5.9 0.3 6.8 4.9 6.2 0.3 6.8 5.3 51 3 51 305 5.4 0 5.6 5.4 06/22/2005 00:40:00 5.8 0.3 6.5 5.3 6.2 0.3 6.8 5.3 53 3 54 305 5.2 0 5.4 5.2 06/22/2005 00:50:00 5.6 0.3 6.5 4.9 6 0.3 6.8 5.3 48 3 48 305 5.2 0 5.4 4.9 06/22/2005 01:00:00 4.8 0.6 6.1 3.4 5.2 0.6 6.5 3.8 43 4 44 305 5.2 0 5.4 4.9 06/22/2005 01:10:00 4 0.3 4.9 3 4.4 0.3 5.3 3.8 43 5 44 305 4.8 0 5.2 4.7 06/22/2005 01:20:00 4.2 0.4 5.3 2.6 4.5 0.4 5.7 3.4 44 5 38 305 4.8 0 4.9 4.7 06/22/2005 01:30:00 4.4 0.4 5.3 3.4 4.7 0.4 5.7 3.8 45 4 42 305 4.8 0 4.9 4.7 06/22/2005 01:40:00 4.4 0.5 6.1 3 4.7 0.4 6.1 3.8 44 4 37 305 4.8 0 5.2 4.7 06/22/2005 01:50:00 4.3 0.4 5.3 3.4 4.5 0.4 5.7 3.8 44 5 43 305 4.8 0 5.2 4.7 06/22/2005 02:00:00 4.1 0.5 5.3 2.6 4.4 0.4 5.7 3 41 6 55 305 4.8 0 4.9 4.7 06/22/2005 02:10:00 3.7 0.4 4.9 2.3 4 0.4 5.3 3 39 6 48 305 4.7 0 4.9 4.4 06/22/2005 02:20:00 3.2 0.3 4.2 2.3 3.6 0.3 4.2 3 33 6 29 305 4.6 0 4.9 4.4 06/22/2005 02:30:00 3.1 0.3 3.8 2.6 3.3 0.3 3.8 2.6 28 5 20 305 4.4 0 4.7 4.2 06/22/2005 02:40:00 3.4 0.5 4.2 2.3 3.5 0.4 4.2 2.6 19 5 21 305 4.2 0 4.7 4.2 06/22/2005 02:50:00 4 0.3 4.6 2.6 3.7 0.4 4.6 2.6 14 3 12 305 4 0.1 4.4 3.7 06/22/2005 03:00:00 4.6 0.2 4.9 4.2 4.2 0.4 4.9 3 14 1 12 305 3.8 0.1 4.4 3.4 06/22/2005 03:10:00 4.6 0.2 4.9 4.2 4.3 0.3 4.9 3.8 14 1 14 305 3.5 0.1 3.9 3.4 06/22/2005 03:20:00 4.3 0.2 4.6 3.8 4 0.2 4.6 3.4 12 2 13 305 3.5 0.1 3.7 3.2 06/22/2005 03:30:00 4.6 0.3 5.3 3.8 4.2 0.4 4.9 3.4 8 2 6 305 3.6 0 3.9 3.2 06/22/2005 03:40:00 5 0.2 5.7 4.6 5 0.3 5.7 4.6 6 2 7 305 3.6 0.2 4.2 3.2 06/22/2005 03:50:00 5.1 0.5 6.5 4.2 5.3 0.5 6.8 4.6 6 3 3 305 3.9 0.1 4.4 3.7 06/22/2005 04:00:00 5 0.5 6.1 3.4 5.2 0.5 6.5 3.8 21 8 27 305 4.2 0.2 4.9 3.7 06/22/2005 04:10:00 5.6 0.4 6.8 4.6 5.7 0.5 6.8 4.6 21 7 18 305 4.4 0 4.9 4.2 06/22/2005 04:20:00 5.4 0.5 6.5 4.2 5.6 0.5 6.8 4.6 18 6 13 305 4.4 0.1 4.9 4.2 06/22/2005 04:30:00 5.2 0.5 6.5 4.2 5.2 0.5 6.8 4.6 27 5 20 305 4.2 0.1 4.7 3.9 06/22/2005 04:40:00 4.7 0.5 6.1 3.4 4.8 0.5 6.1 3.4 22 6 25 305 4.2 0.2 4.7 3.9 06/22/2005 04:50:00 5 0.5 6.8 4.2 5.2 0.6 6.8 4.2 17 10 8 305 4.4 0.2 4.9 3.9 06/22/2005 05:00:00 5.5 0.5 6.5 4.2 5.5 0.6 6.8 4.2 30 4 30 305 4.4 0.1 4.9 4.2 06/22/2005 05:10:00 5.3 0.6 6.8 3.8 5.4 0.5 6.8 4.2 16 8 25 305 4.3 0 4.7 4.2 06/22/2005 05:20:00 5 0.6 6.5 3.8 5.2 0.6 6.5 3.8 19 6 19 305 4.2 0 4.7 4.2 06/22/2005 05:30:00 5 0.5 6.5 3.8 5.1 0.5 6.5 4.2 24 6 23 305 4.2 0 4.7 3.9 06/22/2005 05:40:00 4.1 0.5 4.9 3 4.3 0.5 5.3 3 13 8 4 305 4.3 0 4.7 4.2 06/22/2005 05:50:00 3.9 0.6 5.3 2.6 4 0.5 5.3 2.6 11 6 15 305 4.2 0 4.7 3.9 06/22/2005 06:00:00 3.7 0.8 6.1 1.9 3.9 0.7 5.7 2.6 24 13 19 305 4.4 0.1 4.9 4.2 06/22/2005 06:10:00 2.9 0.4 4.2 1.9 3 0.4 4.2 2.3 24 11 35 305 4.5 0.1 4.9 4.4 06/22/2005 06:20:00 3.8 0.5 5.3 2.6 3.9 0.5 4.9 2.3 24 6 31 305 4.4 0.1 4.9 4.2 06/22/2005 06:30:00 3.7 0.5 5.3 2.6 3.8 0.5 5.3 2.3 15 7 12 305 4.4 0.1 4.9 4.2 06/22/2005 06:40:00 3.8 0.6 4.9 2.6 3.9 0.6 5.3 2.6 22 6 15 305 4.6 0 5.2 4.4 06/22/2005 06:50:00 3 0.2 3.4 2.3 3.2 0.2 3.8 2.6 14 4 16 305 4.8 0 5.2 4.7 06/22/2005 07:00:00 2.1 0.5 3.8 0.7 2.4 0.5 3.4 1.5 18 11 15 305 4.8 0.1 5.4 4.7 06/22/2005 07:10:00 1.4 0.4 1.9 0.4 1.6 0.3 1.9 0.7 33 3 39 305 5 0.1 5.4 4.9 06/22/2005 07:20:00 1.8 0.3 2.3 1.1 1.9 0.3 2.3 1.1 27 6 35 305 4.9 0 5.4 4.9 06/22/2005 07:30:00 2.3 0.2 2.6 1.9 2.4 0.2 3 1.9 16 2 16 305 4.9 0 5.4 4.9 06/22/2005 07:40:00 2.2 0.3 3 1.5 2.3 0.3 3 1.1 21 7 15 305 4.8 0 5.2 4.9 06/22/2005 07:50:00 3 0.4 3.8 1.9 3 0.4 3.8 1.9 4 10 354 305 5 0 5.4 4.9 06/22/2005 08:00:00 3.6 0.3 4.2 3 3.7 0.3 4.6 2.6 355 2 353 305 5.1 0 5.4 4.9 06/22/2005 08:10:00 3.5 0.2 4.2 3 3.6 0.3 4.2 2.6 359 3 353 305 5.2 0 5.4 4.9 06/22/2005 08:20:00 3.3 0.2 3.8 2.3 3.2 0.3 3.8 2.3 354 4 354 305 5.2 0 5.4 5.2 06/22/2005 08:30:00 2.8 0.6 3.4 0.4 2.7 0.5 3.4 1.1 355 10 350 305 5.2 0 5.4 4.9 06/22/2005 08:40:00 2.8 0.6 3.8 1.1 2.8 0.6 3.8 1.5 6 11 356 305 5.1 0 5.4 4.9 06/22/2005 08:50:00 2.9 0.5 4.2 1.5 2.8 0.5 3.8 1.5 6 10 3 305 5.2 0 5.4 4.9 06/22/2005 09:00:00 3.3 0.3 4.2 2.3 3.3 0.4 4.2 2.3 4 4 7 305 5.5 0.1 5.9 5.2 06/22/2005 09:10:00 2.9 0.5 3.8 1.1 2.8 0.6 3.8 1.1 8 7 8 305 5.4 0 5.6 5.4 06/22/2005 09:20:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.1 17 7 12 305 5.3 0 5.6 5.2 06/22/2005 09:30:00 1.9 0.4 2.6 0.7 2.2 0.4 3.4 1.1 17 10 36 305 5.4 0 5.6 5.4 06/22/2005 09:40:00 2 0.4 3 1.1 2.2 0.3 3 1.5 19 10 27 305 5.6 0 5.9 5.4 06/22/2005 09:50:00 2 0.4 3 1.1 2.2 0.3 3 1.5 23 11 21 305 5.7 0 5.9 5.6 06/22/2005 10:00:00 1.9 0.5 3 0.4 2.2 0.4 3 1.1 22 11 11 305 5.8 0 5.9 5.6 06/22/2005 10:10:00 2.5 0.4 3.8 1.5 2.7 0.4 3.8 1.5 20 9 18 305 5.9 0 6.1 5.6 06/22/2005 10:20:00 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.9 18 8 21 305 6 0 6.1 5.6 06/22/2005 10:30:00 2.5 0.5 3.4 1.1 2.6 0.4 3.8 1.1 14 12 16 305 5.9 0 6.1 5.6 06/22/2005 10:40:00 2.4 0.5 4.2 1.1 2.5 0.4 3.4 1.1 14 12 5 305 6 0 6.1 5.9 06/22/2005 10:50:00 2.4 0.5 3.8 1.1 2.6 0.5 3.8 0.7 18 13 21 305 6 0 6.1 5.9 06/22/2005 11:00:00 2.5 0.5 3.4 0.7 2.8 0.4 3.8 1.5 15 9 10 305 6.1 0 6.4 5.9 06/22/2005 11:10:00 2.2 0.4 3 1.1 2.8 0.4 3.8 1.5 17 8 12 305 6 0 6.1 5.9 06/22/2005 11:20:00 2.3 0.4 3.4 1.5 3.1 0.3 3.8 2.3 22 7 37 305 5.8 0.1 6.1 5.4 06/22/2005 11:30:00 2.5 0.4 3.4 1.1 3.1 0.4 4.2 2.3 30 9 16 305 5.3 0 5.6 4.9 06/22/2005 11:40:00 2.2 0.5 3.4 1.1 2.7 0.4 3.8 1.9 25 10 30 305 5.2 0.2 5.4 4.9 06/22/2005 11:50:00 2 0.5 3 0.4 2.4 0.4 3.4 1.5 20 10 29 305 5 0.1 5.4 4.9 06/22/2005 12:00:00 2.2 0.5 3.4 0.4 2.7 0.4 3.8 1.9 17 12 12 305 5.2 0.1 5.4 4.9 06/22/2005 12:10:00 2.3 0.5 3.8 0.7 2.7 0.4 3.8 1.5 17 10 25 305 4.9 0 5.2 4.9 06/22/2005 12:20:00 2.2 0.4 3.4 0.7 2.5 0.4 3.8 1.5 18 9 23 305 5.2 0.2 5.6 4.9 06/22/2005 12:30:00 2.1 0.4 3 1.1 2.4 0.4 3.4 1.5 16 10 4 305 5.2 0.1 5.6 4.9 06/22/2005 12:40:00 2.3 0.4 3.4 1.5 2.5 0.4 3.8 1.5 23 10 14 305 5.3 0 5.6 4.9 06/22/2005 12:50:00 2.4 0.4 3.8 1.1 2.6 0.4 3.8 1.5 22 10 32 305 5.3 0.1 5.9 5.2 06/22/2005 13:00:00 2.5 0.4 3.8 1.1 2.6 0.4 3.8 1.5 19 10 49 305 5.8 0 6.1 5.6 06/22/2005 13:10:00 2.9 0.4 3.8 1.5 3 0.4 4.2 1.9 21 8 38 305 5.7 0.1 6.4 5.4 06/22/2005 13:20:00 3.1 0.4 4.2 1.9 3.3 0.3 4.2 2.6 24 8 42 305 5.8 0.1 6.4 5.6 06/22/2005 13:30:00 3.2 0.4 4.2 2.3 3.4 0.3 4.2 2.6 25 8 32 305 5.8 0.1 6.1 5.4 06/22/2005 13:40:00 3.3 0.3 4.2 1.9 3.5 0.3 4.6 2.6 26 7 32 305 5.3 0 5.6 5.2 06/22/2005 13:50:00 3.3 0.4 4.6 2.3 3.4 0.3 4.6 2.6 28 6 30 305 5.1 0 5.4 4.9 06/22/2005 14:00:00 3.3 0.3 4.2 2.6 3.5 0.4 4.6 2.6 25 7 30 305 5.2 0.1 5.4 4.9 06/22/2005 14:10:00 3.3 0.4 4.2 2.3 3.4 0.3 4.2 2.6 25 6 16 305 5.1 0.2 5.6 4.9 06/22/2005 14:20:00 3.3 0.3 4.6 2.3 3.4 0.3 4.2 2.3 23 6 24 305 5.4 0 5.9 5.2 06/22/2005 14:30:00 3.3 0.3 4.2 2.3 3.5 0.3 4.2 2.6 26 7 27 305 5.4 0 5.6 5.2 06/22/2005 14:40:00 3.6 0.4 4.6 2.3 3.7 0.3 4.6 3 28 7 27 305 5.2 0.1 5.4 4.9 06/22/2005 14:50:00 3.1 0.5 4.6 1.5 3.3 0.4 4.2 2.3 24 9 21 305 5.3 0 5.6 4.9 06/22/2005 15:00:00 2.5 0.4 3.4 1.5 2.8 0.3 3.4 1.9 18 8 28 305 5.2 0 5.9 5.2 06/22/2005 15:10:00 2.5 0.4 3.8 1.1 2.6 0.4 3.8 1.5 18 10 21 305 5.9 0.2 6.9 5.4 06/22/2005 15:20:00 2.5 0.5 3.8 1.1 2.7 0.5 3.8 1.5 8 12 17 305 6.5 0 7.2 6.4 06/22/2005 15:30:00 2.9 0.5 3.8 1.5 2.9 0.5 4.2 1.1 12 9 11 305 6.8 0 7.4 6.7 06/22/2005 15:40:00 2.9 0.4 4.2 1.9 2.9 0.4 4.2 1.9 13 9 16 305 7 0 7.4 6.9 06/22/2005 15:50:00 2.7 0.5 3.8 1.1 2.9 0.4 4.2 1.9 15 11 32 305 7 0 7.7 6.9 06/22/2005 16:00:00 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.9 14 10 29 305 7.2 0.1 7.7 7.2 06/22/2005 16:10:00 2.7 0.4 3.8 1.5 2.9 0.4 3.8 1.9 13 9 32 305 7.1 0 7.4 6.9 06/22/2005 16:20:00 2.5 0.4 3.4 1.1 2.7 0.4 3.8 1.5 15 11 9 305 7.1 0.1 7.4 6.9 06/22/2005 16:30:00 2.6 0.4 3.4 1.5 2.8 0.4 3.8 1.5 17 10 13 305 7.4 0 7.7 7.2 06/22/2005 16:40:00 2.8 0.5 3.8 1.5 2.9 0.4 4.2 1.9 21 8 24 305 7.3 0 7.7 7.2 06/22/2005 16:50:00 2.6 0.4 3.8 1.5 2.7 0.4 3.4 1.5 16 11 354 305 7.3 0 7.7 7.2 06/22/2005 17:00:00 2.5 0.4 3.8 1.1 2.7 0.4 3.8 1.9 9 10 346 305 7.5 0 7.7 7.4 06/22/2005 17:10:00 2.5 0.4 3.4 1.1 2.7 0.4 3.8 1.9 8 8 17 305 7.6 0.2 7.9 7.2 06/22/2005 17:20:00 2.5 0.4 3.4 1.5 2.6 0.4 3.8 1.9 5 10 15 305 7.7 0 7.9 7.4 06/22/2005 17:30:00 2.3 0.4 3.8 1.1 2.5 0.4 3.4 1.5 359 10 357 305 7.7 0 7.9 7.4 06/22/2005 17:40:00 2.4 0.5 3.4 1.1 2.6 0.4 3.8 1.5 6 11 12 305 7.7 0 7.9 7.4 06/22/2005 17:50:00 2.4 0.5 3.4 0.7 2.6 0.4 3.4 1.5 8 10 21 305 7.6 0 7.9 7.7 06/22/2005 18:00:00 2.2 0.5 3 0.7 2.4 0.5 3.4 0.7 11 15 16 305 7.8 0 8.4 7.7 06/22/2005 18:10:00 2.2 0.5 3.4 1.1 2.3 0.5 3.8 0.7 8 16 3 305 8 0.2 8.4 7.7 06/22/2005 18:20:00 2 0.5 3.4 0.4 2.1 0.6 3.4 0.7 355 22 339 305 8.4 0 8.9 8.2 06/22/2005 18:30:00 2 0.6 4.2 0.7 2.2 0.6 4.2 0.4 342 19 346 305 8.6 0 8.9 8.4 06/22/2005 18:40:00 2.1 0.6 3.4 0.7 2.3 0.5 3.8 1.1 330 13 333 305 8.7 0 8.9 8.4 06/22/2005 18:50:00 2.3 0.6 3.8 0.4 2.4 0.6 3.4 1.1 333 13 336 305 8.8 0 9.2 8.4 06/22/2005 19:00:00 2.6 0.5 4.2 1.1 2.7 0.5 3.8 1.5 327 10 322 305 9 0 9.2 8.9 06/22/2005 19:10:00 2.7 0.4 3.8 1.5 2.9 0.5 4.2 1.5 329 10 310 305 9.2 0 9.5 9.2 06/22/2005 19:20:00 2.3 0.5 3.8 1.1 2.5 0.5 3.8 1.1 338 12 341 305 9.2 0 9.5 9.2 06/22/2005 19:30:00 2 0.5 3.4 0.7 2.3 0.5 3.4 0.7 348 12 344 305 9.3 0 9.5 9.2 06/22/2005 19:40:00 1.5 0.6 3 0.4 1.8 0.5 3 0.7 344 16 348 305 9.5 0 9.7 9.2 06/22/2005 19:50:00 2 0.6 3.4 0.7 2.2 0.5 3.4 0.7 336 17 319 305 9.7 0.1 10 9.2 06/22/2005 20:00:00 2 0.6 3.4 0.7 2.2 0.5 3.4 0.7 333 19 323 305 9.8 0 10 9.2 06/22/2005 20:10:00 2 0.6 3.8 0.4 2.3 0.5 3.8 1.1 322 14 333 305 9.8 0 10 9.7 06/22/2005 20:20:00 2 0.5 3.4 0.4 2.2 0.4 3.8 1.1 314 9 321 305 9.9 0 10.2 9.7 06/22/2005 20:30:00 1.8 0.5 3 0.7 2.1 0.4 3.4 0.7 312 11 287 305 10.2 0 10.2 10 06/22/2005 20:40:00 1.5 0.5 2.6 0.4 1.8 0.4 2.6 0.7 311 12 320 305 10.2 0 10.2 9.7 06/22/2005 20:50:00 1.8 0.5 3 0.4 2 0.4 3 1.1 301 11 293 305 10.3 0 10.5 10.2 06/22/2005 21:00:00 1.5 0.5 2.6 0.4 1.6 0.5 2.6 0.4 293 11 292 305 10.6 0 10.8 10.2 06/22/2005 21:10:00 1.3 0.6 2.3 0.4 1.4 0.5 2.6 0.4 279 17 301 305 10.7 0 10.8 10.5 06/22/2005 21:20:00 1.2 0.6 3 0.4 1.5 0.5 3 0.4 269 20 290 305 10.7 0 10.8 10.2 06/22/2005 21:30:00 1.7 0.5 2.6 0.4 1.9 0.5 3 0.7 237 23 277 305 9.8 0.3 10.2 9.2 06/22/2005 21:40:00 1.9 0.5 3.8 0.4 2.1 0.4 3 1.1 221 15 244 305 9 0 9.5 8.9 06/22/2005 21:50:00 2.2 0.5 3 0.4 2.4 0.4 3.4 0.7 205 12 202 305 8.7 0 9.2 8.4 06/22/2005 22:00:00 2.2 0.4 3 1.1 2.4 0.4 3 1.1 211 9 208 305 8.6 0 8.9 8.2 06/22/2005 22:10:00 2.7 0.4 3.4 1.5 2.9 0.4 3.8 1.1 205 9 210 305 8.2 0.1 8.9 8.2 06/22/2005 22:20:00 2.8 0.3 3.8 1.9 2.8 0.3 3.8 1.9 211 10 211 305 8.3 0 8.4 8.2 06/22/2005 22:30:00 2.5 0.4 3.8 1.5 2.6 0.3 3.4 1.9 210 8 211 305 8.3 0 8.4 8.2 06/22/2005 22:40:00 2.8 0.5 3.8 1.5 3 0.5 3.8 1.9 205 9 208 305 8.2 0.1 8.4 7.7 06/22/2005 22:50:00 3 0.4 3.8 2.3 3.3 0.3 3.8 2.6 202 6 203 305 7.8 0.1 7.9 7.7 06/22/2005 23:00:00 3 0.5 4.2 1.5 3.3 0.4 4.2 1.9 203 7 207 305 7.5 0 7.7 7.7 06/22/2005 23:10:00 2.8 0.3 3.4 1.9 3 0.2 3.4 2.3 202 5 194 305 7.5 0 7.7 7.7 06/22/2005 23:20:00 3.2 0.3 3.8 2.3 3.3 0.3 3.8 2.6 212 6 209 305 7.5 0 7.7 7.4 06/22/2005 23:30:00 3.5 0.3 4.6 2.6 3.6 0.3 4.2 2.6 217 6 216 305 7.2 0 7.4 7.2 06/22/2005 23:40:00 3.7 0.3 4.2 3 3.5 0.4 4.2 2.3 219 5 210 305 7.1 0 7.4 7.2 06/22/2005 23:50:00 3.4 0.4 4.2 2.3 3.4 0.4 4.2 2.3 219 6 218 305 7 0 7.2 6.9 06/23/2005 00:00:00 3.5 0.3 4.2 2.6 3.6 0.3 4.6 2.6 213 7 220 305 6.8 0 7.4 6.9 06/23/2005 00:10:00 3.5 0.4 4.6 2.6 3.5 0.3 4.2 2.6 207 7 211 305 6.7 0 6.9 6.7 06/23/2005 00:20:00 3.2 0.3 4.2 2.3 3.4 0.3 3.8 2.3 204 8 204 305 6.6 0 6.9 6.4 06/23/2005 00:30:00 3.3 0.3 4.2 2.6 3.6 0.3 4.2 3 210 5 205 305 6.5 0 6.7 6.4 06/23/2005 00:40:00 4.1 0.3 4.9 3.4 4.3 0.3 4.9 3.4 206 3 206 305 6.5 0 6.7 6.4 06/23/2005 00:50:00 3.9 0.4 4.6 3 4.1 0.4 4.9 3 204 5 210 305 6.3 0 6.4 6.1 06/23/2005 01:00:00 4.5 0.4 5.3 3.4 4.6 0.4 5.7 3 205 8 207 305 6.2 0 6.4 6.1 06/23/2005 01:10:00 4.7 0.4 5.7 3.4 4.8 0.4 5.7 3.4 199 5 195 305 6.2 0 6.4 6.1 06/23/2005 01:20:00 4.5 0.4 5.7 3.4 4.6 0.4 5.7 3.8 200 5 207 305 6.1 0 6.1 6.1 06/23/2005 01:30:00 4.3 0.5 5.7 3 4.3 0.5 5.7 3 199 6 205 305 6 0 6.1 5.9 06/23/2005 01:40:00 4.4 0.4 5.3 3.4 4.6 0.4 5.7 3.8 202 5 205 305 6 0 6.1 5.9 06/23/2005 01:50:00 4.8 0.3 5.7 4.2 5 0.3 6.1 4.2 209 5 213 305 6 0 6.1 5.9 06/23/2005 02:00:00 4.9 0.4 5.7 4.2 5 0.4 6.1 3.8 205 5 213 305 6 0 6.1 5.9 06/23/2005 02:10:00 4.2 0.3 5.3 3.4 4.3 0.3 5.3 3.4 204 4 197 305 6 0 6.1 5.9 06/23/2005 02:20:00 3.9 0.4 4.6 3 4.1 0.4 4.9 3 200 5 204 305 6.1 0 6.1 5.9 06/23/2005 02:30:00 3.9 0.4 4.9 3 4.2 0.4 4.9 3 204 5 205 305 6 0 6.1 5.9 06/23/2005 02:40:00 4.3 0.3 4.9 3 4.5 0.3 5.3 3.4 202 6 203 305 6 0 6.1 5.9 06/23/2005 02:50:00 4.2 0.3 4.9 3.4 4.4 0.3 4.9 3.8 212 6 214 305 5.9 0 5.9 5.9 06/23/2005 03:00:00 4 0.3 4.6 3 4.2 0.3 4.9 3.4 203 5 208 305 5.9 0 5.9 5.9 06/23/2005 03:10:00 4.3 0.4 4.9 3.4 4.5 0.4 5.7 3.4 204 5 202 305 5.9 0 5.9 5.9 06/23/2005 03:20:00 4.3 0.3 4.9 3.4 4.5 0.3 5.3 3.8 203 5 200 305 5.8 0 5.9 5.9 06/23/2005 03:30:00 4.2 0.3 4.9 3.4 4.5 0.3 5.3 3.8 208 5 207 305 5.8 0 5.9 5.9 06/23/2005 03:40:00 4.6 0.4 5.3 3.8 4.7 0.4 5.7 3.8 208 6 210 305 5.9 0 5.9 5.9 06/23/2005 03:50:00 4.8 0.3 5.7 3.8 4.9 0.4 5.7 3.4 210 5 210 305 5.8 0 5.9 5.6 06/23/2005 04:00:00 4.4 0.4 5.3 3.4 4.5 0.3 5.3 3.8 205 5 205 305 5.8 0 5.9 5.6 06/23/2005 04:10:00 4.3 0.4 4.9 3 4.5 0.4 5.3 3.4 200 6 199 305 5.8 0 5.9 5.6 06/23/2005 04:20:00 4.6 0.5 5.7 3.4 4.7 0.4 5.7 3.4 206 6 214 305 5.7 0 5.9 5.6 06/23/2005 04:30:00 4.8 0.5 6.1 3.4 4.9 0.5 6.1 3.8 201 7 214 305 5.8 0 5.9 5.6 06/23/2005 04:40:00 4.6 0.4 5.3 3.8 4.6 0.4 5.3 3.4 208 7 199 305 5.8 0 5.9 5.9 06/23/2005 04:50:00 4.1 0.4 4.9 3.4 4.3 0.4 5.3 3.4 208 5 218 305 5.9 0 5.9 5.9 06/23/2005 05:00:00 4 0.4 4.9 2.3 4 0.4 4.9 3 213 5 218 305 6 0 5.9 5.9 06/23/2005 05:10:00 3.9 0.3 4.6 3 4 0.4 4.9 2.6 204 6 213 305 6 0 6.1 5.9 06/23/2005 05:20:00 4.2 0.3 4.9 3 4.2 0.4 5.3 3 209 6 209 305 6 0 6.1 5.9 06/23/2005 05:30:00 4 0.4 4.9 3 4 0.4 5.3 3 208 5 204 305 6.1 0 6.1 5.9 06/23/2005 05:40:00 4.1 0.3 4.6 3.4 4.3 0.2 4.9 3.4 207 5 210 305 6.1 0 6.1 6.1 06/23/2005 05:50:00 4.3 0.4 4.9 3 4.3 0.4 5.3 3 213 4 215 305 6.2 0 6.4 6.1 06/23/2005 06:00:00 4.2 0.4 4.9 2.6 4.3 0.4 5.3 3 211 4 214 305 6.3 0 6.4 6.1 06/23/2005 06:10:00 4.2 0.4 4.9 3 4.2 0.4 5.3 3 215 5 218 305 6.4 0 6.4 6.1 06/23/2005 06:20:00 4.2 0.4 5.3 2.6 4.2 0.4 5.3 3 213 4 208 305 6.4 0 6.4 6.1 06/23/2005 06:30:00 4.4 0.4 5.3 3.4 4.3 0.5 5.7 3 213 5 213 305 6.5 0 6.4 6.4 06/23/2005 06:40:00 4.3 0.4 4.9 3 4.4 0.4 5.3 3 213 4 210 305 6.5 0 6.9 6.4 06/23/2005 06:50:00 4.9 0.4 5.7 3.8 4.9 0.4 5.7 3.4 212 3 213 305 6.6 0 6.7 6.4 06/23/2005 07:00:00 5.5 0.4 6.5 4.2 5.4 0.5 6.5 3.8 213 4 218 305 6.6 0 6.9 6.4 06/23/2005 07:10:00 5.1 0.5 6.5 3 5 0.5 6.1 3.4 214 5 213 305 6.7 0 6.9 6.4 06/23/2005 07:20:00 4.6 0.3 5.7 3.4 4.6 0.4 5.3 3.4 213 5 224 305 6.8 0 6.9 6.7 06/23/2005 07:30:00 4.2 0.5 5.3 3 4.1 0.5 5.3 3 214 6 214 305 6.9 0 7.2 6.9 06/23/2005 07:40:00 3.5 0.7 4.9 1.5 3.4 0.7 4.6 1.9 220 10 212 305 7 0 7.2 6.9 06/23/2005 07:50:00 2.1 0.4 3 1.1 2.3 0.3 3 1.1 218 9 242 305 7 0 7.2 6.9 06/23/2005 08:00:00 1.5 0.4 2.3 0.4 1.8 0.4 2.6 0.7 221 9 210 305 7 0 7.2 6.9 06/23/2005 08:10:00 1.2 0.4 1.9 0.4 1.6 0.3 2.3 1.1 220 10 199 305 7 0 7.2 6.9 06/23/2005 08:20:00 1.5 0.4 2.3 0.4 1.8 0.3 2.6 1.1 217 8 220 305 7.1 0 7.4 7.2 06/23/2005 08:30:00 1.5 0.4 2.3 0.4 1.8 0.3 2.3 0.7 220 9 225 305 7.2 0 7.4 7.2 06/23/2005 08:40:00 1.8 0.4 3 0.7 2.1 0.4 3 1.1 211 9 198 305 7.4 0 7.7 7.2 06/23/2005 08:50:00 2 0.4 3 0.4 2.2 0.4 3 1.1 220 8 225 305 7.3 0 7.7 7.2 06/23/2005 09:00:00 2.1 0.4 3.4 0.7 2.3 0.4 3 1.1 214 9 205 305 7.5 0 7.7 7.4 06/23/2005 09:10:00 2.3 0.3 3 1.5 2.4 0.3 3 1.5 213 7 208 305 7.7 0 7.9 7.7 06/23/2005 09:20:00 1.8 0.5 2.6 0.4 2 0.4 2.6 0.7 219 7 208 305 8 0 8.2 7.9 06/23/2005 09:30:00 1.3 0.5 2.6 0.4 1.5 0.4 2.6 0.4 217 11 227 305 8.2 0.1 8.4 7.9 06/23/2005 09:40:00 1.3 0.4 2.3 0.4 1.6 0.3 2.3 0.7 213 9 209 305 8.4 0 8.7 8.2 06/23/2005 09:50:00 1.9 0.4 2.6 0.4 2.1 0.4 3 1.1 208 11 211 305 8.4 0 8.4 8.2 06/23/2005 10:00:00 2.1 0.4 3 1.5 2.3 0.3 3.4 1.5 210 7 214 305 8.6 0 8.9 8.4 06/23/2005 10:10:00 2.1 0.4 3 0.7 2.3 0.3 3 1.5 213 9 212 305 8.9 0 9.2 8.7 06/23/2005 10:20:00 1.6 0.5 2.6 0.4 1.9 0.4 2.6 0.7 219 7 224 305 9.3 0.1 9.5 8.9 06/23/2005 10:30:00 1.3 0.4 2.3 0.4 1.6 0.3 2.3 0.7 211 15 182 305 9.7 0 9.7 9.5 06/23/2005 10:40:00 0.6 0.4 1.9 0.4 1.1 0.5 2.3 0.4 206 22 182 305 9.9 0 10.2 9.7 06/23/2005 10:50:00 1.3 0.6 2.6 0.4 1.7 0.5 3 0.4 211 12 194 305 10.1 0.1 10.2 10 06/23/2005 11:00:00 1 0.6 2.3 0.4 1.3 0.6 2.6 0.4 226 27 213 305 10.3 0.2 10.8 9.7 06/23/2005 11:10:00 0.4 0.2 1.5 0.4 0.5 0.2 1.1 0.4 257 76 352 305 11 0.3 11.8 10.5 06/23/2005 11:20:00 1.5 0.6 2.6 0.4 1.9 0.7 3 0.4 337 38 328 305 11.4 0.5 12.1 10.5 06/23/2005 11:30:00 1.3 0.6 2.6 0.4 1.9 0.4 3 0.7 349 17 0 305 10.4 0 10.5 10.2 06/23/2005 11:40:00 1.2 0.5 2.3 0.4 1.7 0.4 2.6 0.7 8 11 352 305 10.1 0 10.2 10 06/23/2005 11:50:00 2 0.8 3 0.4 2.2 0.6 3.4 0.7 7 10 4 305 9.9 0.2 10.2 9.5 06/23/2005 12:00:00 2.8 0.3 3.8 1.9 2.9 0.4 3.8 1.9 20 6 16 305 9.6 0.2 10 9.2 06/23/2005 12:10:00 3.2 0.3 3.8 2.6 3.4 0.3 4.2 2.6 27 4 23 305 10.2 0.1 10.5 10 06/23/2005 12:20:00 3.7 0.2 4.6 2.6 3.7 0.3 4.6 2.6 32 4 28 305 10.6 0.1 10.8 10.5 06/23/2005 12:30:00 4 0.3 4.6 3 3.9 0.4 4.9 3 37 5 35 305 10.8 0 11 10.5 06/23/2005 12:40:00 4.2 0.2 4.9 3.4 4.2 0.3 4.9 3.4 32 5 36 305 10.6 0.2 11 10.2 06/23/2005 12:50:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.4 29 5 28 305 10.1 0.1 10.5 9.7 06/23/2005 13:00:00 4.7 0.3 5.7 3.8 4.7 0.3 5.3 3.8 31 5 28 305 9.8 0 10 9.7 06/23/2005 13:10:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 4.2 31 4 45 305 9.8 0 10 9.5 06/23/2005 13:20:00 4.9 0.4 5.7 3.8 4.9 0.3 5.7 3.4 32 3 32 305 9.9 0 10.2 9.7 06/23/2005 13:30:00 5.6 0.2 6.1 4.9 5.6 0.3 6.1 4.2 35 3 33 305 9.9 0 10 9.7 06/23/2005 13:40:00 5.4 0.3 6.1 4.2 5.4 0.4 6.1 4.2 36 3 33 305 10 0 10.2 9.7 06/23/2005 13:50:00 5.8 0.2 6.5 5.3 5.8 0.3 6.5 4.6 40 2 43 305 10.4 0.1 11 10 06/23/2005 14:00:00 5.9 0.4 6.8 4.9 5.9 0.4 6.8 4.6 43 3 45 305 10.8 0 11 10.5 06/23/2005 14:10:00 6.2 0.4 6.8 5.3 6.2 0.4 7.2 4.9 45 3 42 305 10.9 0.1 11.3 10.5 06/23/2005 14:20:00 6.2 0.3 6.8 4.9 6.1 0.4 7.2 4.2 45 4 46 305 10.8 0 11.3 10.5 06/23/2005 14:30:00 6.4 0.4 7.2 5.7 6.4 0.4 7.2 4.9 48 3 46 305 10.6 0.1 11 10.2 06/23/2005 14:40:00 6.9 0.3 7.6 6.1 6.9 0.4 8 5.7 49 3 48 305 10.7 0 11 10.5 06/23/2005 14:50:00 6.9 0.3 7.6 6.5 7 0.3 7.6 6.1 52 3 54 305 11.1 0.2 11.3 10.8 06/23/2005 15:00:00 6.7 0.3 7.6 5.7 6.7 0.4 7.6 5.3 51 3 53 305 11.2 0 11.3 11 06/23/2005 15:10:00 6.5 0.4 7.2 5.3 6.5 0.5 7.2 5.3 47 4 45 305 10.8 0.1 11 10.5 06/23/2005 15:20:00 6.4 0.3 7.2 5.3 6.4 0.4 7.2 4.9 43 4 43 305 10.6 0.1 10.8 10.2 06/23/2005 15:30:00 6.4 0.3 7.2 5.7 6.4 0.3 7.2 5.3 40 3 35 305 10.3 0 10.5 10 06/23/2005 15:40:00 6.4 0.4 7.2 5.7 6.4 0.4 7.2 4.9 41 4 64 305 10.2 0.1 10.8 10 06/23/2005 15:50:00 6.6 0.3 7.2 5.7 6.7 0.3 7.2 5.7 41 3 40 305 10.1 0 10.5 10 06/23/2005 16:00:00 6.6 0.3 7.2 5.3 6.6 0.4 7.6 4.9 40 4 43 305 10.1 0.1 10.2 9.7 06/23/2005 16:10:00 6.1 0.3 6.8 5.3 6.2 0.4 7.2 4.9 37 3 32 305 9.9 0.2 10.2 9.5 06/23/2005 16:20:00 6.1 0.2 6.5 5.3 6.3 0.3 6.8 5.3 39 3 42 305 9.8 0 10 9.5 06/23/2005 16:30:00 6.3 0.2 6.8 5.7 6.4 0.2 7.2 5.7 36 3 32 305 9.9 0 10.2 9.7 06/23/2005 16:40:00 6.1 0.2 6.8 5.3 6.2 0.3 6.8 4.9 37 2 36 305 9.7 0 10 9.5 06/23/2005 16:50:00 6 0.3 6.5 5.3 6.4 0.3 6.8 4.9 44 3 39 305 9.8 0 10 9.7 06/23/2005 17:00:00 6 0.2 6.8 5.3 6.2 0.3 6.8 5.3 52 3 56 305 10 0.1 10.5 9.7 06/23/2005 17:10:00 6 0.3 6.5 5.3 6.1 0.3 6.8 5.3 53 2 51 305 10.2 0 10.2 10 06/23/2005 17:20:00 6.1 0.3 6.8 5.3 6.1 0.3 6.8 5.3 50 2 53 305 10 0 10.2 9.7 06/23/2005 17:30:00 5.8 0.3 6.5 4.9 6.1 0.3 6.8 5.3 49 2 50 305 10 0 10.2 9.7 06/23/2005 17:40:00 5.7 0.3 6.5 4.9 5.9 0.3 6.5 5.3 49 2 48 305 10 0 10.2 9.5 06/23/2005 17:50:00 5.7 0.3 6.5 4.9 5.9 0.3 6.5 4.9 49 2 48 305 10.2 0.1 10.5 10 06/23/2005 18:00:00 5.6 0.3 6.5 4.6 5.7 0.3 6.5 4.9 51 3 53 305 10.6 0.1 11 9.7 06/23/2005 18:10:00 5.5 0.4 6.1 4.2 5.8 0.3 6.5 5.3 51 3 50 305 11.5 0.1 11.8 11 06/23/2005 18:20:00 4.8 0.6 6.1 3 5.4 0.5 6.5 3.8 48 5 59 305 12.1 0.3 12.9 11.6 06/23/2005 18:30:00 5.1 0.7 8 3 5.5 0.6 7.2 3.8 48 11 87 305 12.8 0.2 13.4 12.4 06/23/2005 18:40:00 5.1 0.7 6.5 2.6 5.5 0.6 6.5 3 47 8 48 305 13 0 13.2 12.6 06/23/2005 18:50:00 5.3 0.4 6.5 3.8 5.6 0.4 6.5 4.6 48 6 55 305 12.8 0.1 13.2 12.4 06/23/2005 19:00:00 4.8 0.4 5.7 3.8 5.2 0.4 6.1 4.2 44 5 50 305 12.3 0.2 12.9 11.8 06/23/2005 19:10:00 4.3 0.6 5.7 2.3 4.8 0.5 5.7 3 40 7 46 305 12.6 0.2 13.2 12.1 06/23/2005 19:20:00 4 0.5 5.3 2.3 4.6 0.5 5.7 3.4 40 7 43 305 12.7 0.1 13.2 12.4 06/23/2005 19:30:00 3.8 0.5 5.3 2.6 4.5 0.4 5.7 3.4 40 6 45 305 12.4 0 12.6 12.4 06/23/2005 19:40:00 4.3 0.5 6.5 2.6 4.8 0.5 7.2 2.6 51 15 79 305 12.6 0.2 13.4 12.4 06/23/2005 19:50:00 4.3 0.8 6.8 2.3 4.2 0.8 6.5 2.6 70 19 33 305 13.6 0.1 14.3 13.2 06/23/2005 20:00:00 3 0.9 5.7 0.7 3.1 0.7 5.7 1.1 95 21 59 305 14.6 0.9 15.9 13.2 06/23/2005 20:10:00 2.9 0.6 4.2 1.5 3.1 0.6 4.6 1.5 91 21 98 305 15.7 0.1 16.2 15.1 06/23/2005 20:20:00 3.2 1 5.7 0.7 3.5 1 5.7 1.1 73 27 53 305 14.6 1.1 15.6 12.9 06/23/2005 20:30:00 2.4 0.7 4.2 0.7 2.7 0.7 4.9 1.1 101 23 34 305 14 0.9 15.6 13.2 06/23/2005 20:40:00 1.2 0.9 3.4 0.4 1.4 0.8 3.4 0.4 103 32 120 305 16.1 0.2 16.5 15.6 06/23/2005 20:50:00 1 0.6 3 0.4 1.2 0.6 3.4 0.4 275 66 264 305 15.3 0.1 16.2 15.1 06/23/2005 21:00:00 0.9 0.6 2.6 0.4 1.7 0.7 3 0.4 16 35 13 305 14.3 0.5 15.3 13.7 06/23/2005 21:10:00 0.8 0.6 2.6 0.4 1.5 0.6 3.4 0.4 16 20 45 305 13.7 0.1 14.3 13.4 06/23/2005 21:20:00 0.6 0.5 3 0.4 1.2 0.7 3 0.4 327 56 21 305 13.8 0 14.3 13.7 06/23/2005 21:30:00 1 0.7 3 0.4 1.4 0.9 3.4 0.4 0 27 21 305 13.8 0.3 14.8 13.4 06/23/2005 21:40:00 2 0.7 3.4 0.4 2.1 0.6 3.8 0.4 135 56 118 305 15.1 0.3 15.3 14.8 06/23/2005 21:50:00 1.7 0.6 2.6 0.4 2.1 0.4 3 0.7 236 15 208 305 14.1 0.6 15.3 13.4 06/23/2005 22:00:00 1.4 0.4 2.3 0.4 1.5 0.3 2.3 0.7 257 9 244 305 13.4 0 14 13.4 06/23/2005 22:10:00 0.5 0.2 1.5 0.4 0.9 0.4 2.3 0.4 293 36 275 305 13.8 0 14.3 13.7 06/23/2005 22:20:00 0.4 0.1 1.1 0.4 0.7 0.4 1.9 0.4 151 107 270 305 14.3 0 14.8 14.3 06/23/2005 22:30:00 0.7 0.4 1.9 0.4 1.2 0.4 1.9 0.4 243 4 239 305 13.6 0.2 14.3 13.2 06/23/2005 22:40:00 0.9 0.3 1.5 0.4 1.4 0.3 1.9 0.7 253 4 244 305 12.8 0.2 13.2 12.4 06/23/2005 22:50:00 0.6 0.3 1.5 0.4 1.2 0.5 1.9 0.4 231 9 228 305 11.9 0.3 12.4 11.3 06/23/2005 23:00:00 1.1 0.8 3.8 0.4 1.2 0.8 3.4 0.4 82 23 80 305 11.5 0 11.8 11.3 06/23/2005 23:10:00 1.5 0.5 2.6 0.4 1.9 0.4 2.6 0.7 14 24 23 305 11.5 0.4 11.8 10.5 06/23/2005 23:20:00 0.8 0.4 2.3 0.4 1.3 0.4 2.3 0.4 21 29 331 305 9.9 0.1 10.5 9.7 06/23/2005 23:30:00 0.4 0.3 1.9 0.4 0.4 0.2 1.1 0.4 71 4 74 305 9.7 0 9.7 9.7 06/23/2005 23:40:00 0.6 0.4 2.3 0.4 0.8 0.5 1.9 0.4 98 102 90 305 9.7 0 9.7 9.5 06/23/2005 23:50:00 1.1 0.5 1.9 0.4 1.4 0.5 2.3 0.4 268 6 278 305 9.7 0 9.7 9.5 06/24/2005 00:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 265 0 305 305 9.7 0 10 9.7 06/24/2005 00:10:00 1 0.8 3.4 0.4 1.2 0.8 3.4 0.4 38 33 98 305 10.2 0.3 10.8 9.7 06/24/2005 00:20:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 353 45 305 305 10.3 0.2 10.8 10 06/24/2005 00:30:00 0.5 0.4 2.6 0.4 1.2 0.4 3 0.4 334 38 338 305 9.5 0.2 10 9.2 06/24/2005 00:40:00 1.1 1 3.8 0.4 1.5 1.2 3.8 0.4 241 58 202 305 9.2 0.1 10 8.9 06/24/2005 00:50:00 1.3 0.6 2.6 0.4 1.8 0.5 3 0.7 177 41 171 305 10.4 0.2 10.8 10 06/24/2005 01:00:00 0.6 0.5 2.3 0.4 0.7 0.5 2.3 0.4 195 82 94 305 10.3 0 10.5 10.2 06/24/2005 01:10:00 0.6 0.5 2.6 0.4 0.6 0.5 2.3 0.4 356 82 87 305 9.5 0.3 10.2 8.9 06/24/2005 01:20:00 0.5 0.2 1.5 0.4 0.9 0.4 1.9 0.4 285 23 261 305 8.6 0 8.9 8.4 06/24/2005 01:30:00 0.4 0 0.7 0.4 0.8 0.4 1.5 0.4 247 19 205 305 8.6 0.1 8.9 8.2 06/24/2005 01:40:00 1.5 0.8 3.4 0.4 1.8 0.5 3 0.7 214 29 197 305 8.4 0 8.4 8.2 06/24/2005 01:50:00 1.3 0.6 2.6 0.4 1.7 0.5 3 0.7 240 14 237 305 8.1 0 8.2 7.9 06/24/2005 02:00:00 0.6 0.3 1.5 0.4 0.9 0.4 1.9 0.4 246 15 244 305 7.7 0 7.9 7.7 06/24/2005 02:10:00 0.4 0.2 1.1 0.4 0.9 0.5 1.9 0.4 244 21 286 305 7.4 0 7.7 7.2 06/24/2005 02:20:00 0.9 0.6 1.9 0.4 1.2 0.4 1.9 0.4 302 4 305 305 7.1 0 7.4 6.9 06/24/2005 02:30:00 1.3 0.8 2.3 0.4 1.4 0.5 2.3 0.4 329 15 307 305 6.8 0 6.9 6.9 06/24/2005 02:40:00 0.5 0.2 1.5 0.4 0.7 0.3 1.5 0.4 5 14 355 305 6.9 0 7.2 6.9 06/24/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 1 305 305 6.7 0.1 7.2 6.4 06/24/2005 03:00:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 331 35 310 305 6.5 0 7.2 6.4 06/24/2005 03:10:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 288 1 305 305 6.1 0.2 6.7 5.9 06/24/2005 03:20:00 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 288 1 305 305 6.1 0.1 6.7 5.6 06/24/2005 03:30:00 0.5 0.4 1.9 0.4 0.8 0.4 1.9 0.4 211 45 197 305 5.7 0.2 6.4 5.4 06/24/2005 03:40:00 0.9 1 3.4 0.4 1.5 0.9 3.4 0.4 205 4 213 305 6.1 0.2 6.9 5.9 06/24/2005 03:50:00 0.5 0.3 1.5 0.4 1.4 0.5 2.3 0.4 212 3 218 305 6.2 0.2 6.9 5.9 06/24/2005 04:00:00 1.1 0.7 2.6 0.4 1.9 0.5 2.6 0.7 217 5 215 305 5.9 0 6.4 5.6 06/24/2005 04:10:00 0.9 0.5 1.9 0.4 1.9 0.3 2.6 1.1 236 4 239 305 6.1 0 6.4 5.9 06/24/2005 04:20:00 0.6 0.3 1.5 0.4 1.2 0.4 1.9 0.7 240 1 240 305 6.1 0.1 6.7 5.9 06/24/2005 04:30:00 0.4 0 0.4 0.4 0.8 0.4 1.9 0.4 240 1 305 305 6 0 6.4 5.9 06/24/2005 04:40:00 0.4 0 0.4 0.4 0.4 0.2 0.7 0.4 273 38 305 305 6 0 6.7 5.9 06/24/2005 04:50:00 0.4 0 0.7 0.4 0.5 0.2 1.5 0.4 290 26 293 305 5.9 0 6.4 5.9 06/24/2005 05:00:00 0.6 0.3 1.1 0.4 0.9 0.4 1.9 0.4 244 14 253 305 6.1 0.2 6.7 5.9 06/24/2005 05:10:00 0.8 0.5 1.9 0.4 1.9 0.7 2.6 0.4 275 30 285 305 6.5 0 6.7 6.4 06/24/2005 05:20:00 1.5 0.6 2.3 0.4 1.6 0.4 2.3 0.7 305 5 303 305 6.2 0.2 6.7 5.9 06/24/2005 05:30:00 1.9 0.3 2.6 1.1 1.7 0.5 2.6 0.7 301 5 304 305 6.1 0 6.4 6.1 06/24/2005 05:40:00 2 0.4 2.6 1.1 1.5 0.3 2.3 0.7 298 4 296 305 6.3 0 6.7 6.1 06/24/2005 05:50:00 2.1 0.6 3 0.7 1.4 0.6 2.6 0.4 291 12 288 305 6.8 0 7.2 6.4 06/24/2005 06:00:00 1.7 0.4 2.6 0.7 1.4 0.3 2.3 0.4 308 6 304 305 7.2 0 7.4 6.9 06/24/2005 06:10:00 1.1 0.3 1.9 0.4 1.7 0.2 2.3 1.1 310 2 313 305 7.3 0 7.4 7.2 06/24/2005 06:20:00 1 0.2 1.5 0.4 1.1 0.3 1.5 0.4 309 4 308 305 7.7 0.2 8.4 7.4 06/24/2005 06:30:00 1 0.4 1.9 0.4 0.8 0.3 1.5 0.4 287 13 271 305 8.6 0 8.9 8.2 06/24/2005 06:40:00 1 0.4 1.5 0.4 1.3 0.3 1.9 0.7 253 13 271 305 8.2 0.1 8.9 8.2 06/24/2005 06:50:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 249 0 305 305 8.5 0 9.2 8.2 06/24/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 249 0 305 305 9.1 0.3 9.7 8.4 06/24/2005 07:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 249 1 305 305 9.7 0.2 10.2 9.2 06/24/2005 07:20:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 216 27 305 305 9.9 0.4 10.2 9.2 06/24/2005 07:30:00 1.1 0.6 2.3 0.4 1.5 0.8 2.6 0.4 200 6 196 305 9.7 0.4 10.2 8.9 06/24/2005 07:40:00 1.5 0.2 2.3 1.1 2 0.2 2.3 1.5 215 3 219 305 8.9 0 9.2 8.9 06/24/2005 07:50:00 1.2 0.4 1.9 0.4 1.4 0.5 2.3 0.4 234 6 219 305 9.1 0 9.5 8.9 06/24/2005 08:00:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 238 27 318 305 9.9 0.4 10.5 9.2 06/24/2005 08:10:00 0.5 0.3 1.9 0.4 0.9 0.5 2.3 0.4 37 20 21 305 9.9 0.2 10.5 9.5 06/24/2005 08:20:00 1.3 0.7 3 0.4 1.7 0.7 3.4 0.4 275 94 186 305 9.8 0 10.2 9.5 06/24/2005 08:30:00 1.8 0.3 2.6 1.1 2.1 0.3 3 1.1 245 12 256 305 9.9 0 10.2 9.7 06/24/2005 08:40:00 1 0.5 2.6 0.4 1.2 0.4 2.3 0.4 238 17 221 305 10.1 0.2 10.5 9.7 06/24/2005 08:50:00 0.6 0.4 1.9 0.4 1.1 0.5 2.3 0.4 279 47 301 305 10.9 0.1 11 10.5 06/24/2005 09:00:00 0.5 0.3 1.9 0.4 1 0.6 2.3 0.4 341 13 347 305 9.9 0.2 10.5 9.7 06/24/2005 09:10:00 0.7 0.5 2.3 0.4 0.9 0.6 2.3 0.4 265 53 193 305 10.8 0.3 11.3 10 06/24/2005 09:20:00 0.7 0.5 2.6 0.4 1 0.7 3 0.4 322 76 355 305 11.6 0.2 12.1 11 06/24/2005 09:30:00 0.6 0.4 1.5 0.4 1.2 0.7 2.6 0.4 12 76 22 305 10.8 0.3 11.3 10.2 06/24/2005 09:40:00 0.6 0.4 1.9 0.4 0.9 0.5 2.3 0.4 313 53 267 305 10.7 0.3 11.3 10.2 06/24/2005 09:50:00 0.8 0.6 2.6 0.4 1.1 0.7 3.8 0.4 292 94 290 305 12.5 0.5 13.4 11.3 06/24/2005 10:00:00 1 0.8 3.4 0.4 1.2 0.8 3.4 0.4 77 58 110 305 13.8 0.4 14.5 13.4 06/24/2005 10:10:00 1 0.6 2.6 0.4 1.8 0.7 3.8 0.7 349 28 348 305 12.8 0.9 14.3 11.6 06/24/2005 10:20:00 0.8 0.4 1.9 0.4 1.4 0.4 3 0.4 356 13 339 305 12 0.2 12.4 11.6 06/24/2005 10:30:00 0.8 0.5 2.3 0.4 1.5 0.6 3 0.4 340 35 351 305 12 0 12.4 11.6 06/24/2005 10:40:00 0.9 0.5 3 0.4 1.7 0.6 3.4 0.4 351 27 13 305 12.2 0 12.4 11.8 06/24/2005 10:50:00 0.9 0.5 2.3 0.4 1.9 0.6 3.4 0.4 12 19 29 305 11.6 0.3 12.1 10.8 06/24/2005 11:00:00 0.5 0.3 1.9 0.4 1.1 0.5 2.3 0.4 331 69 250 305 11.6 0.4 12.9 11 06/24/2005 11:10:00 2.9 1 4.6 0.4 3 1 4.6 0.4 137 38 150 305 14 0.6 15.1 12.9 06/24/2005 11:20:00 2.8 0.8 4.2 0.4 3.1 0.6 4.9 1.1 140 15 131 305 15.1 0.1 15.3 14.8 06/24/2005 11:30:00 2.5 0.8 4.6 0.4 3.1 0.8 4.6 1.5 1 90 23 305 13.5 1.6 15.3 11 06/24/2005 11:40:00 2.4 0.6 3.8 0.4 3.4 0.5 4.9 1.5 22 18 14 305 9.6 0.7 11.3 8.9 06/24/2005 11:50:00 0.8 0.5 2.3 0.4 1.8 0.6 3 0.7 36 22 54 305 10.2 0.4 11 9.7 06/24/2005 12:00:00 0.9 0.5 2.3 0.4 1.3 0.6 2.6 0.4 3 79 59 305 11.7 0.3 12.1 10.8 06/24/2005 12:10:00 1.7 0.8 4.2 0.4 2.2 0.7 4.2 0.4 55 45 128 305 11.7 0.5 13.2 11 06/24/2005 12:20:00 1.7 0.9 3.8 0.4 2 0.8 4.2 0.4 151 51 156 305 14.5 0.7 15.6 13.2 06/24/2005 12:30:00 2.5 0.9 4.6 0.4 3 0.9 5.3 0.7 169 72 144 305 15.6 0.1 15.9 15.3 06/24/2005 12:40:00 3.8 0.8 5.7 1.5 4 0.7 5.7 1.9 153 17 152 305 16 0 16.2 15.9 06/24/2005 12:50:00 4.5 0.8 7.6 2.3 4.6 0.7 6.8 3 146 13 167 305 16.5 0 16.7 16.2 06/24/2005 13:00:00 3.7 0.8 5.3 1.9 4.3 0.7 5.7 2.3 164 11 145 305 16.1 0.1 16.5 15.6 06/24/2005 13:10:00 3.3 0.7 5.7 1.1 3.4 0.6 4.9 1.9 247 43 322 305 14.9 0.8 16.2 13.2 06/24/2005 13:20:00 2.9 0.6 4.2 0.7 2.8 0.6 4.2 1.1 272 17 302 305 12.6 0.3 13.4 11.8 06/24/2005 13:30:00 4.4 0.9 6.8 2.6 4.3 1 7.2 2.6 218 14 205 305 11.3 0.2 12.1 11 06/24/2005 13:40:00 4.7 0.4 5.7 3.8 4.8 0.5 5.7 3.4 213 7 203 305 11 0 11 10.8 06/24/2005 13:50:00 4.7 0.5 6.1 3 4.6 0.5 6.1 3 214 9 221 305 10.8 0 11 10.5 06/24/2005 14:00:00 4.6 0.4 5.7 3 4.6 0.5 5.7 3 210 6 209 305 10.3 0.2 11 10 06/24/2005 14:10:00 4.7 0.5 5.7 3.4 4.6 0.5 5.7 3.4 217 7 214 305 10.2 0 10.2 10 06/24/2005 14:20:00 4.7 0.4 5.7 3.4 4.6 0.5 5.7 3 219 7 222 305 9.9 0.4 10.5 9.2 06/24/2005 14:30:00 4.9 0.4 6.5 3 4.8 0.5 6.1 3.4 217 7 213 305 9.3 0.1 9.7 9.2 06/24/2005 14:40:00 4.8 0.4 5.7 3.8 4.7 0.5 5.7 3 217 6 217 305 8.2 0.4 9.2 7.7 06/24/2005 14:50:00 4.4 0.5 5.3 3 4.2 0.5 5.3 2.6 217 7 219 305 7.8 0.1 8.2 7.7 06/24/2005 15:00:00 3.7 0.4 4.9 2.6 3.7 0.4 4.9 2.6 222 8 213 305 8.1 0 8.2 7.9 06/24/2005 15:10:00 3.5 0.4 4.6 2.3 3.4 0.5 4.9 2.3 212 9 226 305 8 0 8.2 7.9 06/24/2005 15:20:00 3 0.4 4.2 1.9 3.1 0.4 4.2 2.3 213 8 213 305 8.2 0.1 8.9 8.2 06/24/2005 15:30:00 2.9 0.5 4.6 1.9 3.1 0.4 4.2 1.5 222 10 213 305 9 0.1 9.5 8.7 06/24/2005 15:40:00 3.2 0.7 4.6 1.5 3.2 0.6 4.6 1.9 218 9 208 305 9.1 0 9.2 8.9 06/24/2005 15:50:00 3.8 0.5 4.9 2.6 3.9 0.5 5.3 2.6 216 8 221 305 8.4 0.2 9.2 8.2 06/24/2005 16:00:00 3.9 0.4 4.9 2.6 3.9 0.4 4.9 2.6 217 7 212 305 8.2 0.1 8.4 7.9 06/24/2005 16:10:00 4.1 0.4 4.9 3 4 0.4 5.3 3 214 7 221 305 8.1 0.1 8.4 7.9 06/24/2005 16:20:00 4.1 0.4 5.3 3 4.1 0.5 5.3 2.3 210 8 207 305 8.2 0 8.4 7.9 06/24/2005 16:30:00 4.7 0.5 6.1 3.4 4.7 0.5 6.1 3.4 214 7 205 305 7.9 0 8.2 7.7 06/24/2005 16:40:00 4.4 0.4 5.7 3.4 4.4 0.5 5.7 3 217 8 224 305 7.9 0.1 8.2 7.7 06/24/2005 16:50:00 4.3 0.5 5.3 2.6 4.3 0.5 5.3 3 213 5 211 305 7.7 0.1 8.2 7.4 06/24/2005 17:00:00 3.6 0.4 4.6 2.3 3.6 0.4 4.9 2.6 212 7 226 305 7.4 0 7.7 7.2 06/24/2005 17:10:00 3.1 0.4 4.2 1.5 3.2 0.4 4.2 1.5 213 8 196 305 7.7 0 7.9 7.4 06/24/2005 17:20:00 2.6 0.4 3.4 1.1 2.7 0.4 3.8 1.5 217 8 221 305 8.3 0.2 8.7 7.9 06/24/2005 17:30:00 3.3 0.6 4.9 2.3 3.3 0.6 4.9 2.3 216 8 221 305 8.1 0 8.4 7.7 06/24/2005 17:40:00 4 0.4 4.9 2.6 4 0.4 5.3 2.6 216 6 213 305 7.7 0 7.9 7.7 06/24/2005 17:50:00 4.2 0.5 5.3 3 4.2 0.5 5.3 2.6 213 7 208 305 7.5 0 7.7 7.4 06/24/2005 18:00:00 4.6 0.6 5.7 3 4.7 0.6 5.7 3 212 7 217 305 7.5 0 7.7 7.4 06/24/2005 18:10:00 4.9 0.5 6.1 3.8 4.9 0.6 6.1 3 212 6 213 305 7.9 0 8.2 7.7 06/24/2005 18:20:00 4.4 0.4 5.3 3 4.5 0.5 5.3 3 210 7 209 305 7.9 0.1 8.2 7.7 06/24/2005 18:30:00 3.8 0.4 4.9 3 3.9 0.4 4.9 2.6 206 6 212 305 8.1 0.1 8.4 7.9 06/24/2005 18:40:00 3.5 0.4 4.2 2.6 3.5 0.4 4.6 2.6 215 6 221 305 8.4 0 8.7 8.4 06/24/2005 18:50:00 3.8 0.4 4.9 1.9 3.8 0.4 4.9 2.3 218 5 210 305 8.4 0 8.7 8.2 06/24/2005 19:00:00 3.4 0.4 4.2 1.9 3.4 0.4 4.2 2.3 218 9 207 305 8.5 0 8.7 8.2 06/24/2005 19:10:00 2.9 0.4 4.2 1.1 3 0.4 4.2 1.9 218 9 224 305 8.7 0 8.9 8.4 06/24/2005 19:20:00 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.5 218 12 216 305 8.7 0 8.9 8.4 06/24/2005 19:30:00 2.6 0.5 3.8 0.7 2.7 0.5 3.8 1.5 218 9 213 305 8.7 0 8.9 8.4 06/24/2005 19:40:00 3.4 0.4 4.2 2.3 3.4 0.5 4.2 2.3 226 8 224 305 8.6 0 8.9 8.4 06/24/2005 19:50:00 2.6 0.4 3.4 1.1 2.7 0.4 4.2 1.9 226 10 234 305 8.4 0 8.4 8.2 06/24/2005 20:00:00 2.8 0.5 3.8 1.9 2.9 0.5 3.8 1.5 223 9 215 305 8.2 0 8.4 8.2 06/24/2005 20:10:00 3.9 0.4 4.9 2.6 3.9 0.4 4.6 3 217 7 206 305 8.1 0 8.2 7.9 06/24/2005 20:20:00 4.8 0.5 6.1 3.4 4.7 0.5 6.1 3.4 218 7 225 305 7.9 0 8.2 7.7 06/24/2005 20:30:00 4.6 0.5 6.1 3.4 4.6 0.5 6.1 3 221 7 221 305 7.7 0 7.9 7.7 06/24/2005 20:40:00 4.3 0.5 5.3 3 4.3 0.5 5.3 3 218 8 224 305 7.8 0 7.9 7.7 06/24/2005 20:50:00 4.3 0.4 5.7 3.4 4.3 0.5 5.3 3 222 7 237 305 7.5 0.1 7.9 7.2 06/24/2005 21:00:00 3.9 0.4 4.9 2.6 3.9 0.4 5.3 2.6 220 9 223 305 7.2 0 7.4 7.2 06/24/2005 21:10:00 3.3 0.4 4.6 2.3 3.3 0.4 4.2 2.3 220 9 227 305 6.7 0.1 7.2 6.4 06/24/2005 21:20:00 3.4 0.3 4.2 2.6 3.4 0.4 4.2 2.6 213 5 214 305 6.6 0 6.9 6.4 06/24/2005 21:30:00 3.4 0.4 4.6 2.6 3.5 0.4 4.2 2.6 212 7 213 305 6.5 0 6.7 6.4 06/24/2005 21:40:00 2.9 0.4 3.8 1.9 3 0.4 3.8 2.3 208 8 213 305 6.5 0 6.7 6.4 06/24/2005 21:50:00 3.3 0.3 4.2 2.6 3.3 0.3 3.8 2.6 211 4 213 305 6.3 0 6.4 6.1 06/24/2005 22:00:00 3.3 0.3 3.8 2.6 3.4 0.3 4.2 2.6 212 4 213 305 6.1 0 6.1 6.1 06/24/2005 22:10:00 2.8 0.3 3.4 1.9 2.9 0.4 3.4 1.9 214 5 208 305 6.1 0 6.1 6.1 06/24/2005 22:20:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.5 215 5 220 305 6 0 6.1 5.9 06/24/2005 22:30:00 1.8 0.3 2.6 1.1 2.1 0.3 2.6 1.5 211 6 210 305 6.2 0 6.4 5.9 06/24/2005 22:40:00 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.5 222 5 231 305 6.2 0.1 6.4 5.9 06/24/2005 22:50:00 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.3 215 6 217 305 5.9 0 5.9 5.6 06/24/2005 23:00:00 2.9 0.3 3.4 2.3 3 0.3 3.4 2.3 211 5 213 305 5.8 0 5.9 5.6 06/24/2005 23:10:00 3 0.2 3.8 2.3 3.1 0.3 3.8 2.3 212 4 209 305 5.8 0 5.9 5.6 06/24/2005 23:20:00 3.3 0.3 4.2 2.3 3.4 0.3 4.2 2.3 210 5 212 305 5.5 0 5.6 5.4 06/24/2005 23:30:00 3 0.2 3.4 2.6 3.1 0.2 3.8 2.6 214 4 215 305 5.3 0 5.6 5.2 06/24/2005 23:40:00 3 0.3 3.8 2.3 3 0.3 3.8 2.3 217 4 216 305 5 0.1 5.4 4.9 06/24/2005 23:50:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.6 215 3 210 305 4.8 0 4.9 4.7 06/25/2005 00:00:00 3.3 0.3 3.8 2.6 3.4 0.3 4.2 2.3 219 4 213 305 4.5 0.1 5.2 4.4 06/25/2005 00:10:00 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 218 5 224 305 4.4 0 4.9 4.4 06/25/2005 00:20:00 3 0.2 3.4 2.3 3 0.2 3.8 2.3 214 4 213 305 4.4 0.1 4.9 4.4 06/25/2005 00:30:00 2.9 0.3 3.4 2.3 3 0.3 3.8 2.3 210 4 210 305 4.4 0 4.4 4.4 06/25/2005 00:40:00 2.2 0.4 3 1.5 2.4 0.4 3.4 1.9 201 5 208 305 4.4 0 4.4 4.4 06/25/2005 00:50:00 1.7 0.4 2.6 0.7 2 0.3 2.6 1.5 195 8 185 305 4.5 0 4.7 4.4 06/25/2005 01:00:00 1.7 0.4 2.6 0.7 1.7 0.3 2.6 1.1 208 12 209 305 4.8 0 4.9 4.7 06/25/2005 01:10:00 1.8 0.3 2.6 0.7 1.9 0.2 2.6 1.1 217 6 211 305 5.2 0.1 5.4 4.9 06/25/2005 01:20:00 2.2 0.2 2.6 1.9 2.3 0.2 2.6 1.9 212 5 217 305 5.2 0.1 5.4 4.9 06/25/2005 01:30:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 209 5 210 305 5.1 0 5.2 4.9 06/25/2005 01:40:00 2.9 0.2 3.4 2.6 3 0.2 3.4 2.3 208 2 206 305 5 0 5.6 4.9 06/25/2005 01:50:00 2.9 0.2 3.4 2.3 3.1 0.2 3.4 2.6 204 4 205 305 5.2 0 5.4 5.2 06/25/2005 02:00:00 2.5 0.2 3 1.9 2.8 0.2 3.4 2.3 198 3 198 305 5.3 0 5.6 5.4 06/25/2005 02:10:00 2.4 0.2 3 1.9 2.7 0.2 3 1.9 201 4 207 305 5.4 0 5.6 5.4 06/25/2005 02:20:00 2.2 0.2 2.6 1.5 2.5 0.2 3 2.3 197 4 198 305 5.5 0 5.6 5.4 06/25/2005 02:30:00 2.1 0.3 2.6 1.1 2.4 0.2 3 1.9 198 5 204 305 5.5 0 5.6 5.4 06/25/2005 02:40:00 2.1 0.3 3 1.5 2.4 0.3 3 1.9 207 7 205 305 5.7 0 5.9 5.6 06/25/2005 02:50:00 2.4 0.3 3.4 1.5 2.5 0.2 3 1.9 205 7 224 305 5.8 0 5.9 5.6 06/25/2005 03:00:00 2.1 0.3 3 1.1 2.3 0.3 3 1.5 203 9 222 305 5.9 0 5.9 5.9 06/25/2005 03:10:00 2.3 0.3 3 1.5 2.5 0.3 3.4 1.5 209 6 218 305 6 0 6.1 5.9 06/25/2005 03:20:00 2.1 0.4 3 1.1 2.3 0.3 3 1.9 209 5 207 305 6 0 6.1 5.9 06/25/2005 03:30:00 2.1 0.3 2.6 1.5 2.3 0.3 3 1.5 209 6 200 305 6 0 6.1 5.9 06/25/2005 03:40:00 2.3 0.3 3 1.5 2.4 0.3 3 1.9 208 6 215 305 6.1 0 6.1 5.9 06/25/2005 03:50:00 1.8 0.3 2.6 1.1 2.1 0.2 2.6 1.5 204 7 214 305 6.3 0 6.4 6.1 06/25/2005 04:00:00 1.7 0.3 2.3 1.1 2 0.2 2.6 1.5 212 5 221 305 6.5 0 6.9 6.4 06/25/2005 04:10:00 1.9 0.3 2.6 1.1 2.1 0.2 2.6 1.5 212 5 210 305 6.7 0 6.9 6.7 06/25/2005 04:20:00 1.6 0.3 2.3 0.7 1.9 0.2 2.3 1.5 210 5 220 305 6.8 0 6.9 6.9 06/25/2005 04:30:00 0.9 0.5 1.9 0.4 1.5 0.3 2.3 0.7 198 3 207 305 6.9 0 7.2 6.9 06/25/2005 04:40:00 0.9 0.4 1.9 0.4 1.5 0.3 1.9 0.7 211 10 212 305 7.1 0 7.4 6.9 06/25/2005 04:50:00 0.9 0.4 1.9 0.4 1.5 0.3 2.3 0.7 216 4 208 305 7.3 0 7.7 7.2 06/25/2005 05:00:00 1 0.3 1.9 0.4 1.4 0.2 1.9 0.7 213 11 208 305 7.5 0 7.7 7.4 06/25/2005 05:10:00 0.6 0.3 1.5 0.4 1 0.4 1.9 0.4 195 2 198 305 7.5 0 7.7 7.4 06/25/2005 05:20:00 0.4 0.2 1.1 0.4 0.9 0.3 1.5 0.4 205 7 204 305 7.4 0 7.7 7.4 06/25/2005 05:30:00 0.7 0.4 1.5 0.4 1.1 0.3 1.9 0.7 208 5 210 305 7.5 0 7.7 7.4 06/25/2005 05:40:00 1.3 0.2 1.9 0.7 1.6 0.2 2.3 1.1 193 4 194 305 7.5 0 7.7 7.4 06/25/2005 05:50:00 1.8 0.4 2.6 1.1 2.1 0.3 2.6 1.5 210 8 224 305 7.6 0 7.7 7.7 06/25/2005 06:00:00 2 0.2 2.6 1.5 2.2 0.2 2.6 1.9 206 6 200 305 7.5 0 7.7 7.4 06/25/2005 06:10:00 2 0.3 3 1.1 2.2 0.3 2.6 1.5 213 7 207 305 7.5 0 7.7 7.4 06/25/2005 06:20:00 2.3 0.3 3 1.5 2.5 0.3 3.4 1.5 207 5 208 305 7.6 0 7.7 7.7 06/25/2005 06:30:00 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.5 211 8 213 305 7.6 0 7.7 7.7 06/25/2005 06:40:00 2.1 0.4 3 1.1 2.3 0.3 3 1.5 206 6 202 305 7.6 0 7.7 7.7 06/25/2005 06:50:00 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.5 208 6 208 305 7.6 0 7.7 7.7 06/25/2005 07:00:00 1.7 0.6 3 0.4 2 0.5 3.4 0.4 195 5 192 305 7.7 0 7.9 7.7 06/25/2005 07:10:00 1.7 0.4 2.6 0.4 1.9 0.4 2.6 0.7 203 6 193 305 7.9 0 7.9 7.7 06/25/2005 07:20:00 0.7 0.3 1.5 0.4 1.2 0.3 1.9 0.4 199 6 211 305 8 0 8.4 7.9 06/25/2005 07:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 196 1 305 305 8.2 0.2 9.2 7.9 06/25/2005 07:40:00 0.5 0.4 1.9 0.4 0.6 0.4 1.9 0.4 205 15 238 305 9.5 0.2 10.2 8.9 06/25/2005 07:50:00 2.4 0.5 3.4 1.1 2.5 0.4 3.4 1.5 232 5 237 305 9.3 0.1 10 8.9 06/25/2005 08:00:00 3 0.4 3.8 2.3 3 0.4 3.8 2.3 234 9 239 305 8.9 0.1 9.7 8.7 06/25/2005 08:10:00 2.9 0.5 3.8 1.5 3 0.4 4.2 1.9 232 6 242 305 8.7 0 9.2 8.4 06/25/2005 08:20:00 3 0.3 3.8 2.3 3.2 0.3 3.8 2.3 227 5 232 305 8.6 0 9.2 8.4 06/25/2005 08:30:00 2.7 0.3 3.4 1.9 2.9 0.3 3.8 1.9 232 5 230 305 8.6 0 9.2 8.4 06/25/2005 08:40:00 2.4 0.3 3.4 1.5 2.7 0.3 3.4 1.9 224 4 224 305 8.7 0 9.2 8.4 06/25/2005 08:50:00 2 0.5 3 0.7 2.4 0.4 3.4 1.5 216 8 217 305 8.8 0 9.2 8.7 06/25/2005 09:00:00 1.5 0.4 2.6 0.7 2.1 0.4 3 1.1 206 8 192 305 9 0 9.5 8.9 06/25/2005 09:10:00 1.5 0.4 2.3 0.4 2 0.3 2.6 1.1 211 7 219 305 9.2 0 9.7 9.2 06/25/2005 09:20:00 1.8 0.4 3 0.4 2.3 0.4 3.4 1.5 206 7 215 305 9.3 0.1 9.7 9.2 06/25/2005 09:30:00 2.3 0.4 3 1.1 2.6 0.4 3.4 1.5 206 8 216 305 9.5 0 10 9.2 06/25/2005 09:40:00 2.5 0.4 3.8 1.5 2.9 0.4 3.8 1.9 204 7 207 305 9.7 0 10 9.5 06/25/2005 09:50:00 2.9 0.4 3.8 1.5 3.3 0.4 4.2 1.9 203 6 206 305 9.7 0 10 9.7 06/25/2005 10:00:00 3 0.4 3.8 1.9 3.4 0.4 4.2 2.3 202 6 202 305 9.7 0 10 9.7 06/25/2005 10:10:00 3.2 0.5 4.2 1.5 3.5 0.4 4.6 2.6 202 8 209 305 9.8 0 10 9.7 06/25/2005 10:20:00 3.6 0.5 4.9 2.3 3.8 0.5 5.3 2.6 212 6 221 305 9.7 0.1 10 9.5 06/25/2005 10:30:00 4.6 0.6 5.7 3 4.5 0.5 5.7 3.4 215 5 221 305 9.1 0 9.5 8.9 06/25/2005 10:40:00 4.2 0.5 5.3 2.3 4.1 0.5 5.3 2.6 210 5 220 305 9 0 9.5 8.9 06/25/2005 10:50:00 3.7 0.4 4.6 2.6 3.8 0.4 4.6 2.6 208 7 203 305 9.1 0 9.7 8.9 06/25/2005 11:00:00 3.3 0.4 4.2 2.6 3.4 0.4 4.2 2.3 206 6 217 305 9.1 0 9.7 8.9 06/25/2005 11:10:00 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.3 202 9 203 305 9.1 0 9.7 8.9 06/25/2005 11:20:00 3.4 0.4 4.6 2.3 3.4 0.5 4.6 2.3 201 7 197 305 9.1 0 9.7 8.9 06/25/2005 11:30:00 3.1 0.4 3.8 1.9 3.2 0.4 4.2 1.9 201 10 198 305 9.2 0 10 9.2 06/25/2005 11:40:00 3.1 0.4 4.2 1.9 3.3 0.4 4.6 1.9 208 8 198 305 9.2 0 10 8.9 06/25/2005 11:50:00 3.1 0.4 4.2 1.9 3.2 0.4 4.2 2.3 203 9 208 305 9.1 0 9.7 8.9 06/25/2005 12:00:00 3.2 0.6 4.9 1.9 3.3 0.5 4.9 2.3 203 10 218 305 8.9 0 9.5 8.9 06/25/2005 12:10:00 3.4 0.6 4.9 2.3 3.5 0.5 5.3 2.3 204 10 202 305 8.9 0 9.5 8.9 06/25/2005 12:20:00 3.6 0.6 5.3 1.9 3.8 0.6 5.7 2.3 204 9 217 305 8.9 0.1 9.5 8.7 06/25/2005 12:30:00 3.7 0.6 5.3 2.3 3.6 0.5 5.3 1.9 206 9 208 305 8.9 0 9.5 8.7 06/25/2005 12:40:00 3.5 0.6 4.9 2.3 3.5 0.6 5.3 2.3 203 9 210 305 9.1 0 9.7 8.9 06/25/2005 12:50:00 3.4 0.6 4.6 1.9 3.4 0.5 4.9 1.9 198 9 208 305 9.2 0 9.7 8.9 06/25/2005 13:00:00 3.4 0.5 4.6 1.9 3.6 0.5 4.9 2.3 196 9 188 305 9.1 0 9.7 9.2 06/25/2005 13:10:00 3.6 0.5 4.6 1.9 3.8 0.5 4.9 2.3 194 6 196 305 9.1 0 9.7 8.9 06/25/2005 13:20:00 3.2 0.5 4.6 1.9 3.5 0.5 4.6 2.3 193 7 194 305 9 0 9.7 8.9 06/25/2005 13:30:00 3.7 0.5 4.6 1.9 3.8 0.4 4.6 2.6 196 7 197 305 9.1 0 9.7 8.9 06/25/2005 13:40:00 3.8 0.4 4.9 2.3 4 0.4 4.9 3 196 6 199 305 9.1 0 9.7 8.9 06/25/2005 13:50:00 3.9 0.5 5.3 2.6 4 0.5 5.3 2.6 201 7 213 305 9.1 0 9.7 8.9 06/25/2005 14:00:00 4.2 0.5 5.3 3 4.2 0.5 5.3 3 204 7 210 305 9 0 9.7 8.9 06/25/2005 14:10:00 4 0.6 5.7 2.6 4 0.5 5.3 2.6 212 9 221 305 9.1 0 9.5 8.9 06/25/2005 14:20:00 3.9 0.5 4.9 2.3 4 0.5 5.3 2.6 210 7 217 305 9.1 0 9.5 8.9 06/25/2005 14:30:00 4.4 0.5 5.7 3 4.5 0.5 5.7 3 206 6 207 305 9.1 0 9.5 8.9 06/25/2005 14:40:00 4.5 0.6 6.1 3 4.6 0.6 6.1 2.6 198 6 208 305 9.1 0 9.7 9.2 06/25/2005 14:50:00 5.2 0.6 6.5 3.8 5.1 0.5 6.5 3.8 206 8 215 305 9.3 0.1 9.7 9.2 06/25/2005 15:00:00 5.3 0.6 6.8 3.4 5.1 0.7 6.5 3.4 211 6 215 305 9.3 0 9.5 9.2 06/25/2005 15:10:00 5.1 0.5 6.1 3.8 5.1 0.5 6.5 3.4 202 5 197 305 9.2 0 9.5 9.2 06/25/2005 15:20:00 5 0.6 6.8 3.4 4.9 0.6 6.5 3.4 203 6 210 305 9.3 0 9.5 9.2 06/25/2005 15:30:00 5.5 0.7 7.2 3.4 5.3 0.8 7.2 3 217 6 220 305 9.3 0 9.7 9.2 06/25/2005 15:40:00 5.6 0.7 6.8 3.8 5.5 0.7 7.2 3.4 221 7 224 305 9.3 0 9.5 9.2 06/25/2005 15:50:00 5.9 0.7 7.2 4.2 5.6 0.7 7.2 3.8 218 6 213 305 9.3 0.1 9.7 9.2 06/25/2005 16:00:00 5.7 0.6 6.8 4.2 5.5 0.7 7.2 3.8 219 5 219 305 9.3 0 9.5 9.2 06/25/2005 16:10:00 6.3 0.7 7.6 4.2 6.1 0.7 7.6 4.2 219 6 217 305 9.1 0.1 9.5 8.9 06/25/2005 16:20:00 6.3 0.5 7.6 4.6 6.3 0.6 7.6 4.2 215 6 201 305 8.8 0 8.9 8.7 06/25/2005 16:30:00 5.6 0.6 6.8 3.8 5.7 0.7 7.6 3.8 217 7 211 305 8.9 0 9.2 8.7 06/25/2005 16:40:00 5.5 0.5 6.8 4.2 5.6 0.5 6.5 4.2 219 6 227 305 8.6 0.1 9.2 8.4 06/25/2005 16:50:00 4.9 0.5 6.1 3.4 4.8 0.6 6.1 3.4 216 6 215 305 8.7 0 9.2 8.4 06/25/2005 17:00:00 5.1 0.5 6.5 3.8 5.1 0.5 6.5 3.4 218 6 215 305 8.7 0 9.2 8.4 06/25/2005 17:10:00 5.3 0.6 6.5 3.8 5.1 0.7 6.5 3.4 219 6 224 305 8.6 0 9.2 8.4 06/25/2005 17:20:00 5.2 0.6 6.5 3.8 5.1 0.6 6.5 3.4 219 6 222 305 8.7 0 9.2 8.7 06/25/2005 17:30:00 5 0.5 6.5 3.4 4.9 0.6 6.5 3.4 215 7 211 305 8.7 0 9.2 8.4 06/25/2005 17:40:00 5.2 0.7 6.5 3.4 5 0.6 6.5 3.4 212 7 215 305 8.8 0 9.2 8.4 06/25/2005 17:50:00 5.2 0.6 6.8 3.4 5.1 0.6 6.5 3.4 211 6 201 305 8.7 0 9.2 8.4 06/25/2005 18:00:00 5.1 0.5 6.5 3.4 5.1 0.6 6.1 3.4 208 7 208 305 8.7 0 9.2 8.4 06/25/2005 18:10:00 5.4 0.4 6.1 3.8 5.3 0.4 6.1 3.8 203 5 206 305 8.9 0 9.5 8.7 06/25/2005 18:20:00 5.5 0.5 6.8 3.8 5.5 0.5 6.5 4.2 209 6 215 305 9.1 0 9.5 8.9 06/25/2005 18:30:00 5.3 0.6 6.5 3.8 5.2 0.6 6.8 3.8 211 7 210 305 9 0 9.2 8.9 06/25/2005 18:40:00 5.1 0.6 6.5 3.4 5.1 0.5 6.5 3.8 213 6 213 305 8.9 0 9.2 8.9 06/25/2005 18:50:00 5.1 0.5 6.5 3.4 5 0.5 6.1 3.4 211 7 210 305 9.1 0.1 9.2 8.9 06/25/2005 19:00:00 5 0.5 6.1 3.8 4.9 0.5 6.1 3.4 212 6 213 305 8.8 0.1 9.2 8.7 06/25/2005 19:10:00 4.9 0.5 6.1 3.8 4.9 0.5 6.1 3.4 213 6 210 305 8.7 0 8.9 8.4 06/25/2005 19:20:00 5.1 0.4 6.1 3.8 5.1 0.5 6.1 3 215 5 222 305 8.4 0.1 8.7 8.2 06/25/2005 19:30:00 4.9 0.5 6.1 3.4 4.8 0.5 6.1 3.4 215 6 209 305 8.2 0 8.4 8.2 06/25/2005 19:40:00 4.3 0.5 5.3 2.6 4.4 0.4 5.3 3 220 6 214 305 8.1 0 8.2 7.9 06/25/2005 19:50:00 3.9 0.5 4.9 2.6 3.9 0.4 4.9 3 221 6 213 305 8.1 0 8.2 7.9 06/25/2005 20:00:00 4.1 0.5 5.3 3 4.1 0.5 5.3 2.6 221 6 225 305 8 0 8.2 7.9 06/25/2005 20:10:00 4.2 0.5 4.9 3 4.2 0.5 5.3 3 223 6 224 305 8 0 8.2 7.9 06/25/2005 20:20:00 3.8 0.5 4.9 2.6 3.8 0.4 4.9 2.6 227 7 221 305 7.9 0 8.2 7.9 06/25/2005 20:30:00 3.5 0.4 4.6 2.3 3.6 0.4 4.6 2.6 231 6 226 305 7.7 0 8.2 7.7 06/25/2005 20:40:00 3.4 0.4 4.6 2.3 3.5 0.4 4.6 2.3 226 7 230 305 7.6 0 8.2 7.4 06/25/2005 20:50:00 3.5 0.4 4.6 2.3 3.5 0.4 4.2 2.3 227 6 225 305 7.7 0.1 8.2 7.7 06/25/2005 21:00:00 3.6 0.4 4.6 2.6 3.6 0.3 4.6 2.6 227 7 228 305 7.6 0 8.2 7.4 06/25/2005 21:10:00 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.3 222 8 219 305 7.6 0 7.9 7.4 06/25/2005 21:20:00 3.4 0.4 4.6 2.6 3.4 0.4 4.2 2.3 218 6 218 305 7.5 0 7.9 7.4 06/25/2005 21:30:00 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.3 214 6 208 305 7.5 0 7.9 7.4 06/25/2005 21:40:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 221 6 222 305 7.3 0 7.7 7.4 06/25/2005 21:50:00 3.8 0.4 4.6 2.6 3.8 0.4 4.9 2.6 221 5 217 305 7.3 0 7.7 7.2 06/25/2005 22:00:00 4.1 0.4 4.9 2.6 4.1 0.5 4.9 2.6 222 6 222 305 7.3 0.1 7.9 7.2 06/25/2005 22:10:00 4.1 0.4 4.9 3 4 0.5 4.9 2.6 222 5 219 305 7.2 0.2 7.7 7.2 06/25/2005 22:20:00 4.6 0.4 5.7 3.4 4.5 0.5 5.7 3 228 5 232 305 7.1 0.1 7.7 7.2 06/25/2005 22:30:00 4.4 0.5 5.3 3 4.2 0.5 5.3 3 227 6 232 305 7 0 7.7 6.9 06/25/2005 22:40:00 4 0.5 4.9 2.6 3.9 0.5 4.9 2.6 220 5 220 305 7 0 7.4 6.9 06/25/2005 22:50:00 4.3 0.4 4.9 3.4 4.2 0.4 4.9 3 223 6 225 305 6.9 0 7.2 6.9 06/25/2005 23:00:00 4.1 0.5 5.3 3 4 0.4 4.9 2.6 222 6 219 305 6.9 0 7.2 6.9 06/25/2005 23:10:00 3.9 0.4 4.6 2.6 3.9 0.4 4.6 2.6 223 5 224 305 6.8 0 6.9 6.9 06/25/2005 23:20:00 4.5 0.5 5.7 3 4.4 0.6 5.7 2.6 211 7 203 305 6.9 0 7.2 6.9 06/25/2005 23:30:00 4.5 0.5 5.7 3 4.6 0.4 5.3 3 211 6 213 305 6.9 0 7.2 6.9 06/25/2005 23:40:00 4.6 0.4 5.3 3.4 4.6 0.4 5.3 3 214 6 214 305 6.9 0 7.2 6.9 06/25/2005 23:50:00 4.7 0.4 5.7 3.4 4.8 0.4 5.7 3.8 205 5 212 305 7 0 7.2 6.9 06/26/2005 00:00:00 4.4 0.3 5.3 3.4 4.4 0.4 5.3 3.4 202 6 209 305 6.9 0 7.4 6.9 06/26/2005 00:10:00 4.4 0.5 5.3 3 4.5 0.5 5.3 3 207 6 203 305 7 0 7.2 6.9 06/26/2005 00:20:00 4.1 0.4 4.9 3 4 0.5 4.9 2.6 210 6 212 305 7 0 7.2 6.9 06/26/2005 00:30:00 3.6 0.5 4.6 2.3 3.7 0.5 4.9 2.3 204 8 214 305 7 0 7.2 6.9 06/26/2005 00:40:00 3.7 0.3 4.6 2.3 3.8 0.4 4.9 2.6 199 6 200 305 7 0 7.2 6.9 06/26/2005 00:50:00 4.2 0.3 4.9 3.4 4.2 0.4 5.3 3 207 6 207 305 7 0 7.2 6.9 06/26/2005 01:00:00 4.1 0.4 4.9 3 4.1 0.4 4.9 2.6 207 6 202 305 7 0 7.2 6.9 06/26/2005 01:10:00 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.6 213 7 210 305 7 0 7.2 6.9 06/26/2005 01:20:00 3.4 0.4 4.6 1.9 3.4 0.4 4.2 2.3 217 6 214 305 7 0 7.2 6.9 06/26/2005 01:30:00 3.5 0.4 4.2 2.3 3.5 0.4 4.6 2.3 206 8 211 305 7 0 7.2 6.9 06/26/2005 01:40:00 3.9 0.5 4.9 2.3 4 0.5 4.9 2.6 202 7 199 305 7 0 7.2 6.9 06/26/2005 01:50:00 4.9 0.5 5.7 3.4 4.9 0.5 6.1 3.4 212 8 212 305 7 0 7.2 6.9 06/26/2005 02:00:00 4.5 0.5 5.3 3.4 4.3 0.6 5.7 3 214 6 220 305 6.9 0 7.2 6.9 06/26/2005 02:10:00 4.6 0.5 5.7 3 4.6 0.5 5.7 3 214 8 215 305 7 0 7.2 6.9 06/26/2005 02:20:00 5.3 0.6 6.5 3.8 5.2 0.6 6.5 3.4 214 7 212 305 7 0 7.2 6.9 06/26/2005 02:30:00 5.5 0.5 6.5 3.8 5.3 0.7 6.5 3.8 214 5 219 305 7 0 7.2 6.9 06/26/2005 02:40:00 5.2 0.5 6.1 3.8 5.1 0.5 6.1 3.4 218 6 210 305 7 0 7.2 6.9 06/26/2005 02:50:00 5.1 0.5 6.1 3.8 4.9 0.5 6.1 3.4 217 6 218 305 7 0 7.2 6.9 06/26/2005 03:00:00 4.7 0.5 5.7 2.6 4.8 0.5 5.7 3.4 208 6 205 305 7 0 7.2 6.9 06/26/2005 03:10:00 4.9 0.4 6.1 3.8 5 0.4 5.7 3.8 207 5 209 305 7 0 7.2 6.9 06/26/2005 03:20:00 4.8 0.5 5.7 3.4 4.9 0.5 5.7 3 206 5 204 305 7 0 7.2 6.9 06/26/2005 03:30:00 4.8 0.5 5.7 3 4.8 0.5 5.7 3 206 5 210 305 7 0 7.2 6.9 06/26/2005 03:40:00 5 0.5 6.1 3.4 5 0.5 6.1 3.8 210 5 210 305 7 0 7.2 6.9 06/26/2005 03:50:00 5.3 0.4 6.1 4.2 5.3 0.5 6.5 3.8 206 4 215 305 7 0 7.2 6.9 06/26/2005 04:00:00 5.4 0.5 6.5 3.8 5.3 0.6 6.5 3.4 212 6 210 305 7 0 7.2 6.9 06/26/2005 04:10:00 5.8 0.5 6.8 4.2 5.6 0.6 6.8 4.2 216 4 218 305 7 0 7.2 6.9 06/26/2005 04:20:00 5.7 0.4 6.5 4.9 5.6 0.5 6.5 4.2 216 5 217 305 7 0 7.2 6.9 06/26/2005 04:30:00 5.7 0.4 6.8 4.2 5.6 0.4 6.5 4.2 216 4 217 305 7 0 7.2 6.9 06/26/2005 04:40:00 5.3 0.3 6.5 4.2 5.3 0.5 6.5 4.2 210 5 217 305 7 0 7.2 6.9 06/26/2005 04:50:00 5.5 0.4 6.5 4.6 5.6 0.4 6.5 4.2 210 5 205 305 7 0 7.2 6.9 06/26/2005 05:00:00 5.8 0.5 6.8 4.6 5.7 0.6 7.2 4.2 215 5 214 305 7 0 7.2 6.9 06/26/2005 05:10:00 5.8 0.4 6.5 4.6 6 0.6 7.2 3.8 214 5 220 305 7 0 7.2 6.9 06/26/2005 05:20:00 5.5 0.4 6.5 4.6 5.7 0.6 6.8 4.2 214 5 217 305 7 0 7.2 7.2 06/26/2005 05:30:00 5.1 0.4 6.1 4.2 5.3 0.6 6.8 3.8 213 5 213 305 7 0 7.2 7.2 06/26/2005 05:40:00 5.3 0.4 6.5 4.2 5.6 0.5 6.5 4.2 218 5 223 305 7 0 7.2 7.2 06/26/2005 05:50:00 5.1 0.3 5.7 4.2 5.3 0.5 6.5 4.2 216 4 215 305 7 0 7.2 6.9 06/26/2005 06:00:00 5.2 0.4 6.1 3.4 5.1 0.5 6.5 3.4 215 5 213 305 7 0 7.2 6.9 06/26/2005 06:10:00 5.1 0.4 6.1 3.8 5.1 0.5 5.7 3.8 216 5 215 305 6.9 0 7.2 6.9 06/26/2005 06:20:00 4.6 0.5 5.7 3 4.5 0.6 5.7 3 212 5 215 305 6.8 0 7.2 6.9 06/26/2005 06:30:00 4.4 0.4 5.3 3 4.4 0.5 5.3 3 211 5 213 305 6.8 0 7.2 6.9 06/26/2005 06:40:00 4.5 0.4 5.3 2.6 4.4 0.5 5.7 3 214 6 221 305 6.8 0 7.2 6.9 06/26/2005 06:50:00 4.5 0.5 5.7 3 4.4 0.5 5.3 2.6 214 5 213 305 6.8 0 6.9 6.7 06/26/2005 07:00:00 4.9 0.4 5.7 3.8 4.8 0.5 5.7 3.4 217 5 223 305 6.7 0 6.9 6.7 06/26/2005 07:10:00 4.8 0.4 5.7 3.8 4.8 0.4 5.7 3.8 217 4 218 305 6.7 0 6.9 6.7 06/26/2005 07:20:00 4.4 0.4 5.3 3 4.4 0.4 5.3 2.6 212 5 203 305 6.7 0 6.9 6.7 06/26/2005 07:30:00 4.8 0.3 5.7 3.8 4.8 0.4 5.7 3.4 212 4 208 305 6.7 0 6.9 6.7 06/26/2005 07:40:00 5.1 0.4 6.1 3.4 5 0.6 6.1 3.4 211 5 213 305 6.7 0 6.9 6.7 06/26/2005 07:50:00 5.4 0.5 6.1 3.4 5.3 0.5 6.5 3.8 213 5 206 305 6.8 0 6.9 6.7 06/26/2005 08:00:00 5.7 0.6 6.8 3.8 5.5 0.7 6.8 3.8 216 4 217 305 6.9 0 7.2 6.9 06/26/2005 08:10:00 5.6 0.7 6.8 3.4 5.6 0.7 6.8 3.4 214 5 221 305 6.8 0 6.9 6.7 06/26/2005 08:20:00 5 0.5 6.1 3.8 4.9 0.6 6.1 3.4 213 6 208 305 6.9 0 7.2 6.9 06/26/2005 08:30:00 4.9 0.5 6.1 3.4 4.8 0.5 6.1 3 213 5 215 305 7 0 7.2 6.9 06/26/2005 08:40:00 5 0.4 6.1 3.8 5 0.5 6.1 3.8 217 6 213 305 7.2 0 7.4 7.2 06/26/2005 08:50:00 5.3 0.4 6.5 4.2 5.2 0.5 6.5 3.8 219 5 219 305 7.2 0 7.4 7.2 06/26/2005 09:00:00 4.9 0.4 5.7 3.8 4.8 0.5 5.7 3.8 220 5 227 305 7.4 0 7.7 7.4 06/26/2005 09:10:00 4.8 0.5 5.7 3.4 4.7 0.6 5.7 3 218 5 216 305 7.3 0 7.7 7.2 06/26/2005 09:20:00 4.7 0.4 5.7 3.4 4.6 0.4 5.7 3.4 213 6 214 305 7.5 0 7.7 7.4 06/26/2005 09:30:00 4.9 0.5 6.1 3.4 4.8 0.5 5.7 3.4 214 6 206 305 7.5 0 7.7 7.4 06/26/2005 09:40:00 5.3 0.5 6.5 3.8 5.2 0.6 6.5 3.4 215 5 215 305 7.6 0 7.7 7.4 06/26/2005 09:50:00 5.2 0.4 6.1 4.2 5.3 0.5 6.5 3.8 218 5 215 305 7.6 0 7.7 7.4 06/26/2005 10:00:00 5.1 0.5 6.1 3.8 5.1 0.6 6.5 3.8 217 6 227 305 7.7 0 7.9 7.7 06/26/2005 10:10:00 5.1 0.5 6.5 3.8 5 0.6 6.5 3.4 216 6 220 305 7.9 0 7.9 7.7 06/26/2005 10:20:00 5.6 0.5 6.5 4.6 5.6 0.5 6.8 4.6 217 5 221 305 7.9 0 8.2 7.9 06/26/2005 10:30:00 5.7 0.5 6.8 4.2 5.8 0.6 7.2 3.8 218 5 218 305 8 0 8.2 7.9 06/26/2005 10:40:00 6.1 0.5 7.2 4.6 6.3 0.7 7.6 4.6 218 5 214 305 7.9 0 8.2 7.7 06/26/2005 10:50:00 5.9 0.5 6.8 4.2 6.1 0.6 7.6 3.4 220 5 218 305 7.9 0 8.2 7.7 06/26/2005 11:00:00 5.8 0.6 6.8 4.2 5.8 0.6 7.2 4.2 222 5 218 305 7.9 0 8.2 7.7 06/26/2005 11:10:00 5.4 0.5 6.5 4.2 5.4 0.6 6.8 4.2 219 5 224 305 8 0 8.2 7.9 06/26/2005 11:20:00 4.9 0.5 6.1 3.8 4.8 0.6 6.5 3 215 7 214 305 8.1 0.1 8.4 7.9 06/26/2005 11:30:00 5.3 0.5 6.5 3.8 5.3 0.6 6.5 3.4 210 6 213 305 8.1 0 8.9 7.9 06/26/2005 11:40:00 5.6 0.5 6.5 4.2 5.8 0.5 7.2 4.2 210 5 211 305 8 0 8.7 7.9 06/26/2005 11:50:00 5.6 0.5 6.8 4.2 5.8 0.5 7.2 4.6 209 6 214 305 8.1 0 8.7 7.9 06/26/2005 12:00:00 5.8 0.5 6.8 3.8 6.1 0.6 7.2 3.8 210 5 213 305 8 0 8.7 7.9 06/26/2005 12:10:00 5.7 0.5 6.8 3.4 5.9 0.6 6.8 3.8 211 6 211 305 8.2 0.1 8.9 8.2 06/26/2005 12:20:00 5.6 0.6 6.8 3.8 5.8 0.6 7.2 4.6 214 6 207 305 8.2 0 8.7 8.2 06/26/2005 12:30:00 5.8 0.5 6.8 4.2 6 0.6 7.6 4.2 217 6 212 305 8.2 0 8.7 7.9 06/26/2005 12:40:00 5.7 0.5 6.8 4.2 5.9 0.5 7.2 4.6 222 6 220 305 8.2 0.1 8.7 7.9 06/26/2005 12:50:00 5.9 0.5 7.2 4.2 6.1 0.6 7.6 4.2 221 5 222 305 8.3 0.1 8.9 8.2 06/26/2005 13:00:00 5.8 0.5 7.2 4.6 6.1 0.6 7.6 4.2 226 6 234 305 8.6 0.1 9.2 8.2 06/26/2005 13:10:00 5.9 0.6 7.2 4.2 6.1 0.6 7.6 4.6 224 6 231 305 8.8 0 9.2 8.4 06/26/2005 13:20:00 5.8 0.5 6.8 4.6 6 0.5 6.8 4.2 223 6 229 305 8.6 0 8.9 8.4 06/26/2005 13:30:00 5.9 0.5 7.2 4.2 6.1 0.6 7.2 3.4 219 6 220 305 8.5 0 8.7 8.4 06/26/2005 13:40:00 5.6 0.5 6.8 4.2 5.8 0.6 7.2 4.2 221 5 227 305 8.5 0.1 8.9 8.2 06/26/2005 13:50:00 5.8 0.5 7.2 4.2 6 0.6 7.2 4.6 218 6 220 305 8.6 0 8.9 8.2 06/26/2005 14:00:00 6.4 0.5 7.6 4.6 6.6 0.6 7.6 4.2 218 5 214 305 8.6 0 8.9 8.4 06/26/2005 14:10:00 6.3 0.5 7.6 4.9 6.5 0.5 7.6 4.6 220 5 218 305 8.6 0 8.7 8.2 06/26/2005 14:20:00 6.2 0.6 7.2 4.2 6.3 0.7 7.6 4.2 219 5 213 305 8.8 0.1 9.2 8.4 06/26/2005 14:30:00 6.2 0.6 7.6 4.6 6.4 0.6 8 4.9 222 6 224 305 8.9 0.1 9.2 8.7 06/26/2005 14:40:00 6.4 0.6 7.6 4.6 6.7 0.7 8 4.6 222 5 232 305 8.8 0 9.2 8.4 06/26/2005 14:50:00 6.4 0.6 8 4.9 6.6 0.7 8.4 4.6 221 6 220 305 8.9 0 9.2 8.7 06/26/2005 15:00:00 6.8 0.7 8 4.6 7.1 0.8 8.4 4.9 220 5 223 305 8.7 0 8.9 8.4 06/26/2005 15:10:00 6.7 0.6 8 5.3 6.8 0.7 8.4 4.9 222 5 230 305 8.7 0.1 9.2 8.4 06/26/2005 15:20:00 6.7 0.6 8 4.6 6.9 0.7 8.4 4.9 221 5 223 305 8.5 0.1 8.9 8.2 06/26/2005 15:30:00 6.6 0.7 8 4.6 6.8 0.8 8.4 4.6 220 5 219 305 8.3 0.1 8.7 8.2 06/26/2005 15:40:00 6.8 0.5 7.6 5.3 7 0.6 8.4 5.3 220 4 218 305 8.2 0 8.7 7.9 06/26/2005 15:50:00 6.4 0.7 7.6 4.6 6.6 0.7 8 4.9 221 5 226 305 8 0 8.4 7.9 06/26/2005 16:00:00 6.4 0.6 8 4.9 6.7 0.6 8 4.9 220 5 221 305 7.9 0 8.4 7.7 06/26/2005 16:10:00 6.4 0.5 7.6 4.9 6.6 0.7 8 4.9 219 5 224 305 7.9 0 8.2 7.7 06/26/2005 16:20:00 6.1 0.6 7.6 4.6 6.3 0.6 8 4.6 223 6 219 305 7.9 0 8.4 7.7 06/26/2005 16:30:00 5.9 0.6 8 4.6 6.2 0.6 7.6 4.6 222 6 224 305 7.9 0 8.4 7.7 06/26/2005 16:40:00 5.9 0.6 6.8 4.6 6.1 0.7 7.6 4.2 225 6 221 305 7.8 0 8.2 7.7 06/26/2005 16:50:00 6 0.7 7.6 4.6 6.2 0.7 8 4.6 229 5 226 305 7.9 0.1 8.4 7.7 06/26/2005 17:00:00 6.2 0.6 7.6 4.2 6.5 0.6 7.6 4.6 229 5 234 305 7.6 0 8.2 7.4 06/26/2005 17:10:00 6.1 0.6 7.6 4.6 6.2 0.6 8 4.6 232 5 232 305 7.5 0 7.9 7.4 06/26/2005 17:20:00 6 0.6 7.2 4.2 6.2 0.6 7.6 4.9 232 5 231 305 7.5 0 7.7 7.4 06/26/2005 17:30:00 6 0.5 7.2 4.6 6.1 0.6 7.6 4.6 232 5 228 305 7.4 0 7.7 7.4 06/26/2005 17:40:00 5.9 0.6 6.8 4.2 6.1 0.6 7.6 4.6 229 5 228 305 7.5 0 7.7 7.4 06/26/2005 17:50:00 5.8 0.6 6.8 4.2 5.9 0.6 7.2 4.6 230 6 231 305 7.5 0 7.7 7.4 06/26/2005 18:00:00 6 0.6 7.2 4.2 6.1 0.6 7.6 4.6 230 5 227 305 7.4 0 7.7 7.4 06/26/2005 18:10:00 6.3 0.6 7.6 4.6 6.3 0.8 8 4.6 229 5 223 305 7.5 0 7.7 7.4 06/26/2005 18:20:00 6.4 0.5 7.2 4.6 6.4 0.6 7.6 4.9 228 5 234 305 7.6 0 7.7 7.4 06/26/2005 18:30:00 6.5 0.5 7.6 4.6 6.5 0.6 8.4 4.9 230 5 227 305 7.5 0 7.7 7.4 06/26/2005 18:40:00 6.7 0.6 8 4.6 6.6 0.7 8 4.9 230 6 230 305 7.5 0 7.7 7.4 06/26/2005 18:50:00 7.1 0.6 8.4 5.3 7 0.7 8.4 4.9 228 5 231 305 7.3 0 7.7 7.4 06/26/2005 19:00:00 7.2 0.5 8.4 5.7 7 0.6 8.4 5.7 227 4 233 305 7.4 0 7.7 7.4 06/26/2005 19:10:00 7 0.6 8.4 4.9 6.9 0.7 8.8 4.9 227 5 228 305 7.3 0 7.4 7.2 06/26/2005 19:20:00 6.6 0.6 8.4 4.9 6.6 0.7 8.4 4.9 225 5 231 305 7.4 0 7.7 7.2 06/26/2005 19:30:00 6.3 0.5 7.6 4.9 6.5 0.6 8 4.9 222 5 224 305 7.5 0 7.7 7.4 06/26/2005 19:40:00 6.8 0.6 8 4.9 6.8 0.7 8.4 5.3 223 5 224 305 7.5 0 7.7 7.4 06/26/2005 19:50:00 6.7 0.7 8.4 5.3 6.7 0.7 8.4 4.9 224 5 219 305 7.6 0 7.7 7.7 06/26/2005 20:00:00 6.8 0.6 8.4 5.3 6.6 0.6 8 4.9 226 5 221 305 7.7 0 7.9 7.7 06/26/2005 20:10:00 6.7 0.7 8 4.6 6.6 0.7 8.4 4.6 226 6 227 305 7.7 0 7.9 7.7 06/26/2005 20:20:00 6.1 0.6 7.6 4.6 6.1 0.6 7.6 4.6 225 6 232 305 7.5 0 7.7 7.4 06/26/2005 20:30:00 5.9 0.6 7.6 4.2 5.9 0.6 7.6 4.2 224 6 221 305 7.5 0 7.7 7.4 06/26/2005 20:40:00 5.6 0.6 6.8 4.2 5.7 0.6 6.8 4.2 226 6 227 305 7.6 0 7.7 7.4 06/26/2005 20:50:00 5.8 0.5 7.2 4.2 5.8 0.5 7.2 4.6 227 6 224 305 7.5 0 7.7 7.4 06/26/2005 21:00:00 5.7 0.5 6.8 4.6 5.7 0.6 7.2 4.2 225 6 224 305 7.5 0 7.7 7.4 06/26/2005 21:10:00 5.7 0.5 6.8 4.6 5.6 0.6 6.8 3.8 227 6 224 305 7.5 0 7.9 7.4 06/26/2005 21:20:00 5.5 0.5 6.5 4.2 5.5 0.5 6.5 4.2 226 6 223 305 7.5 0 7.7 7.4 06/26/2005 21:30:00 5.5 0.5 6.8 4.2 5.4 0.5 6.5 4.2 225 6 231 305 7.4 0 7.7 7.4 06/26/2005 21:40:00 5.6 0.6 7.2 4.2 5.2 0.6 6.8 3.8 227 6 243 305 7.4 0 7.7 7.4 06/26/2005 21:50:00 5.6 0.5 6.5 4.2 5.3 0.5 6.5 3.8 228 6 224 305 7.4 0 7.7 7.4 06/26/2005 22:00:00 5.5 0.5 6.8 4.2 5.2 0.5 6.5 3.4 229 7 236 305 7.5 0 7.7 7.4 06/26/2005 22:10:00 5.1 0.5 6.5 3.8 4.9 0.5 6.1 3 232 6 238 305 7.5 0 7.7 7.4 06/26/2005 22:20:00 5.3 0.5 6.8 3.4 5.1 0.5 6.8 3.8 226 6 218 305 7.5 0 7.7 7.4 06/26/2005 22:30:00 5.4 0.6 6.8 3.8 5.1 0.5 6.8 3.8 225 7 235 305 7.5 0 7.7 7.4 06/26/2005 22:40:00 5.4 0.5 6.5 4.2 5.3 0.5 6.5 4.2 224 6 229 305 7.3 0 7.4 7.2 06/26/2005 22:50:00 5.6 0.5 6.5 3.8 5.4 0.5 6.5 3.8 224 6 227 305 7.3 0 7.4 7.2 06/26/2005 23:00:00 5.6 0.5 6.5 3.8 5.3 0.5 6.5 3.8 224 5 230 305 7.2 0 7.4 7.2 06/26/2005 23:10:00 5.5 0.5 6.8 4.2 5.2 0.5 6.5 4.2 226 6 232 305 7.2 0 7.4 7.2 06/26/2005 23:20:00 5.3 0.6 6.8 3.8 5.1 0.5 6.5 3.8 225 7 230 305 7.2 0 7.4 7.2 06/26/2005 23:30:00 5.2 0.5 6.5 3.8 4.9 0.5 6.8 3.4 226 6 234 305 7.1 0 7.2 7.2 06/26/2005 23:40:00 5.8 0.6 7.2 4.2 5.5 0.6 6.8 3.8 227 5 228 305 7.2 0 7.4 7.2 06/26/2005 23:50:00 5.9 0.5 7.2 4.2 5.6 0.6 7.2 3.8 219 6 223 305 7.1 0 7.2 7.2 06/27/2005 00:00:00 6 0.4 6.8 4.9 5.8 0.5 7.2 3.8 219 6 225 305 7.1 0 7.7 7.2 06/27/2005 00:10:00 5.9 0.5 7.2 4.6 5.7 0.5 7.2 4.2 222 5 213 305 7.1 0 7.2 7.2 06/27/2005 00:20:00 5.7 0.4 6.8 4.6 5.6 0.5 6.8 4.6 220 5 222 305 7 0 7.2 7.2 06/27/2005 00:30:00 5.9 0.4 7.2 4.6 5.8 0.5 7.2 4.2 216 6 211 305 7 0 7.7 7.2 06/27/2005 00:40:00 6.1 0.5 7.2 4.6 6 0.4 6.8 4.6 219 5 221 305 7 0 7.2 7.2 06/27/2005 00:50:00 6 0.4 7.2 4.9 5.8 0.6 7.2 4.2 215 6 210 305 7 0 7.2 7.2 06/27/2005 01:00:00 5.4 0.6 7.2 3.8 5.2 0.7 7.2 3.8 215 6 214 305 7 0 7.2 7.2 06/27/2005 01:10:00 5 0.6 6.5 3.8 4.8 0.6 6.8 3.4 216 7 216 305 7 0 7.2 6.9 06/27/2005 01:20:00 5.7 0.4 6.8 4.6 5.5 0.5 6.8 4.2 221 6 217 305 7 0 7.2 6.9 06/27/2005 01:30:00 5.5 0.5 6.5 4.2 5.4 0.5 6.5 4.2 219 6 225 305 7 0 7.2 6.9 06/27/2005 01:40:00 5.8 0.5 6.8 4.6 5.5 0.6 6.8 3.8 214 5 214 305 7 0 7.2 6.9 06/27/2005 01:50:00 6 0.5 7.2 4.6 5.7 0.7 6.8 3.8 214 6 217 305 7 0 7.2 6.9 06/27/2005 02:00:00 5.9 0.5 6.8 4.2 5.7 0.5 6.8 4.2 216 5 221 305 7 0 7.2 6.9 06/27/2005 02:10:00 6.4 0.5 7.6 4.9 6.2 0.6 7.2 3.8 218 5 221 305 7 0 7.2 6.9 06/27/2005 02:20:00 6.7 0.5 8 4.9 6.5 0.5 8 4.9 218 4 215 305 7 0 7.2 6.9 06/27/2005 02:30:00 6.4 0.5 7.6 4.9 6.2 0.6 7.6 4.9 220 5 216 305 7 0 7.2 6.9 06/27/2005 02:40:00 6.1 0.5 7.2 4.9 5.9 0.6 7.2 4.2 220 6 224 305 7 0 7.2 6.9 06/27/2005 02:50:00 6.3 0.5 7.2 4.6 6 0.6 7.6 4.6 222 5 223 305 7 0 7.2 6.9 06/27/2005 03:00:00 6.3 0.5 7.6 4.9 5.9 0.6 7.2 4.2 224 5 231 305 7 0 7.2 6.9 06/27/2005 03:10:00 6.3 0.5 7.6 4.9 6 0.5 7.2 4.6 222 5 225 305 7 0 7.2 6.9 06/27/2005 03:20:00 5.9 0.5 7.2 4.6 5.7 0.5 7.2 4.2 221 5 212 305 7 0 7.2 6.9 06/27/2005 03:30:00 5.9 0.5 7.2 4.6 5.8 0.5 6.8 4.6 221 6 224 305 7 0 7.2 6.9 06/27/2005 03:40:00 5.8 0.5 6.8 4.6 5.6 0.5 6.8 4.2 224 6 231 305 7 0 7.2 6.9 06/27/2005 03:50:00 5.8 0.5 6.8 4.6 5.5 0.6 6.8 3.8 223 6 218 305 7 0 7.2 6.9 06/27/2005 04:00:00 5.6 0.5 6.8 4.2 5.2 0.6 6.5 3.8 224 6 230 305 7 0 7.2 6.9 06/27/2005 04:10:00 5.4 0.6 6.8 3.8 5.2 0.6 6.5 3.8 228 6 231 305 6.9 0 7.2 6.9 06/27/2005 04:20:00 5.4 0.7 7.6 3.8 5.1 0.7 7.6 3.4 231 7 241 305 6.8 0 7.2 6.9 06/27/2005 04:30:00 5.3 0.8 7.2 3.4 5.1 0.7 6.8 3.4 235 7 235 305 6.8 0 6.9 6.7 06/27/2005 04:40:00 5.4 0.7 7.2 3.8 5 0.7 6.8 3.4 236 7 223 305 6.7 0 6.9 6.7 06/27/2005 04:50:00 5.2 0.5 6.8 3.8 5.1 0.5 6.8 3.4 231 6 225 305 6.7 0 6.9 6.7 06/27/2005 05:00:00 5 0.6 6.5 3.4 4.7 0.7 6.5 3 238 7 237 305 6.6 0 6.9 6.4 06/27/2005 05:10:00 5 0.6 6.5 3.4 4.7 0.6 6.5 3.4 234 7 232 305 6.6 0 6.7 6.4 06/27/2005 05:20:00 5 0.6 6.5 3.4 4.7 0.6 6.5 3.4 233 8 230 305 6.5 0 6.7 6.4 06/27/2005 05:30:00 5.1 0.7 7.2 3.4 4.8 0.7 6.5 3 235 6 235 305 6.5 0 6.7 6.4 06/27/2005 05:40:00 4.8 0.6 6.5 3 4.6 0.6 6.1 3 237 7 239 305 6.5 0 6.7 6.4 06/27/2005 05:50:00 4.5 0.6 6.1 3 4.4 0.5 5.7 3 237 6 243 305 6.5 0 6.7 6.4 06/27/2005 06:00:00 4.4 0.5 5.7 3 4.1 0.5 5.7 3 237 7 248 305 6.5 0 6.7 6.4 06/27/2005 06:10:00 3.8 0.5 5.3 2.6 3.7 0.5 4.9 2.6 237 7 236 305 6.6 0 6.7 6.4 06/27/2005 06:20:00 3.9 0.6 5.7 2.3 3.8 0.6 5.3 2.3 239 8 246 305 6.6 0 6.9 6.4 06/27/2005 06:30:00 4 0.5 5.7 2.6 3.9 0.5 5.3 2.3 236 9 242 305 6.7 0 6.9 6.4 06/27/2005 06:40:00 4.1 0.4 5.3 3 3.9 0.5 4.9 3 235 7 251 305 6.7 0 6.9 6.7 06/27/2005 06:50:00 4.6 0.6 6.1 3.4 4.3 0.6 5.3 2.6 236 7 239 305 6.6 0 6.9 6.4 06/27/2005 07:00:00 4.5 0.5 5.7 3.4 4.4 0.5 5.7 3.4 232 8 232 305 6.6 0 6.9 6.4 06/27/2005 07:10:00 4.8 0.5 6.1 3.4 4.6 0.5 6.1 3.4 235 7 234 305 6.6 0 6.9 6.4 06/27/2005 07:20:00 4.6 0.6 6.5 2.6 4.5 0.6 5.7 3 236 8 244 305 6.6 0 6.7 6.4 06/27/2005 07:30:00 4.2 0.7 6.1 2.6 4 0.7 6.1 2.6 234 9 258 305 6.5 0 6.7 6.4 06/27/2005 07:40:00 4.4 0.5 5.7 2.6 4.1 0.5 5.3 3 240 6 243 305 6.5 0 6.7 6.4 06/27/2005 07:50:00 4.2 0.6 5.3 2.6 4 0.5 5.3 3 242 7 244 305 6.5 0 6.4 6.1 06/27/2005 08:00:00 4.5 0.6 5.7 3 4.3 0.6 5.7 3 245 8 244 305 6.3 0 6.4 6.1 06/27/2005 08:10:00 4.5 0.7 6.1 2.6 4.4 0.7 5.7 2.3 243 6 248 305 6.3 0 6.4 6.1 06/27/2005 08:20:00 4.8 0.7 6.5 3.4 4.6 0.6 6.1 3 248 7 245 305 6.2 0 6.4 6.1 06/27/2005 08:30:00 4.6 0.6 6.1 2.6 4.4 0.6 6.5 3 243 7 248 305 6.2 0 6.4 6.1 06/27/2005 08:40:00 4.5 0.6 6.1 3 4.3 0.6 5.7 3 247 6 248 305 6.1 0 6.1 5.9 06/27/2005 08:50:00 4.4 0.6 6.1 3 4.2 0.5 5.7 3 242 7 240 305 6.1 0 6.1 5.9 06/27/2005 09:00:00 4.7 0.6 6.5 3.4 4.5 0.5 5.7 3 243 8 254 305 6.1 0 6.4 5.9 06/27/2005 09:10:00 4.5 0.5 5.7 3 4.3 0.5 5.7 2.6 241 7 233 305 6.1 0 6.4 5.9 06/27/2005 09:20:00 4.7 0.6 6.5 3 4.5 0.6 6.1 3 246 8 247 305 6.1 0 6.4 5.9 06/27/2005 09:30:00 4.8 0.5 5.7 3.4 4.6 0.5 6.1 3.4 243 7 238 305 6.2 0 6.4 6.1 06/27/2005 09:40:00 4.6 0.5 5.7 3.4 4.4 0.5 5.7 2.6 242 8 242 305 6.2 0 6.4 6.1 06/27/2005 09:50:00 4.9 0.7 6.1 3.4 4.7 0.6 6.1 3 245 7 235 305 6.3 0 6.4 6.1 06/27/2005 10:00:00 5.1 0.5 6.5 3.8 4.9 0.6 6.5 3 246 7 246 305 6.3 0 6.4 6.1 06/27/2005 10:10:00 4.6 0.7 6.1 3 4.3 0.7 6.1 2.6 249 8 256 305 6.3 0 6.7 6.1 06/27/2005 10:20:00 4.6 0.5 5.7 3 4.5 0.5 5.7 3 247 7 246 305 6.5 0 6.7 6.1 06/27/2005 10:30:00 4.3 0.5 5.3 3 4.2 0.5 5.3 2.6 243 9 241 305 6.5 0.1 6.9 6.1 06/27/2005 10:40:00 4.2 0.5 5.7 2.6 4.2 0.6 5.3 2.6 243 10 233 305 6.5 0 6.7 6.4 06/27/2005 10:50:00 4 0.7 5.7 2.3 3.9 0.6 5.3 2.3 247 9 256 305 6.8 0 7.2 6.4 06/27/2005 11:00:00 4 0.6 5.3 2.3 4 0.6 5.7 2.6 244 10 234 305 6.9 0 7.2 6.7 06/27/2005 11:10:00 4.3 0.5 5.7 3 4.1 0.6 5.7 2.6 244 9 244 305 7 0 7.2 6.9 06/27/2005 11:20:00 4.1 0.5 6.1 2.6 4 0.5 5.3 2.3 244 9 250 305 7 0.1 7.4 6.9 06/27/2005 11:30:00 4.3 0.6 6.1 2.6 4.3 0.7 6.5 2.6 245 9 241 305 7.2 0 7.4 7.2 06/27/2005 11:40:00 3.9 0.5 4.9 2.6 4 0.4 4.9 3 232 9 214 305 7.3 0 7.7 7.2 06/27/2005 11:50:00 4.3 0.5 5.7 2.6 4.3 0.4 5.3 3 232 9 228 305 7.3 0 7.7 7.2 06/27/2005 12:00:00 4.3 0.4 5.3 3.4 4.3 0.5 5.7 3 229 7 228 305 7.7 0.2 8.7 7.4 06/27/2005 12:10:00 4.6 0.5 6.5 3 4.6 0.5 6.1 3 227 7 234 305 8 0 8.4 7.9 06/27/2005 12:20:00 4.7 0.5 5.7 3.4 4.7 0.5 5.7 3.4 229 7 232 305 8.1 0 8.4 7.9 06/27/2005 12:30:00 4.8 0.6 6.5 3 4.7 0.5 6.1 3 233 9 246 305 8.3 0 8.4 8.2 06/27/2005 12:40:00 4.9 0.5 6.1 3.4 4.8 0.6 6.1 3.4 230 8 225 305 8.3 0 8.4 8.2 06/27/2005 12:50:00 4.8 0.5 6.1 3.4 4.7 0.5 5.7 3.4 225 8 233 305 8.3 0 8.7 8.2 06/27/2005 13:00:00 4.7 0.5 5.7 3.4 4.7 0.5 6.1 3 227 8 234 305 8.2 0.1 8.4 7.9 06/27/2005 13:10:00 4.9 0.5 6.5 3.4 4.9 0.5 6.1 3.4 222 7 223 305 8.2 0.1 8.4 7.9 06/27/2005 13:20:00 5.2 0.5 6.5 3.4 5.2 0.5 6.1 3.8 223 6 229 305 8 0 8.4 7.9 06/27/2005 13:30:00 5.2 0.5 6.5 3.8 5.1 0.5 6.5 3.8 223 7 212 305 8.1 0 8.4 7.9 06/27/2005 13:40:00 5.1 0.5 6.5 3.8 5 0.5 6.1 3.4 224 7 233 305 8.2 0.1 8.7 7.9 06/27/2005 13:50:00 5.3 0.5 6.5 3.8 5.1 0.6 6.5 3.8 226 7 225 305 8.4 0.2 9.2 8.2 06/27/2005 14:00:00 5.4 0.5 7.6 3.8 5.2 0.5 6.8 3.8 224 7 229 305 8.4 0.1 9.2 8.2 06/27/2005 14:10:00 5.4 0.6 6.8 4.2 5.3 0.6 6.8 3.8 225 8 214 305 8.3 0.1 8.9 7.9 06/27/2005 14:20:00 4.9 0.6 6.8 3.4 4.8 0.6 6.5 3.4 221 8 238 305 8.4 0.1 9.2 8.2 06/27/2005 14:30:00 5 0.5 6.5 3.4 4.9 0.5 6.5 3.4 226 8 214 305 8.5 0.1 9.2 8.2 06/27/2005 14:40:00 4.6 0.5 6.5 3.4 4.6 0.5 5.7 3 220 9 210 305 8.6 0.1 9.2 8.2 06/27/2005 14:50:00 4.6 0.5 5.7 3 4.5 0.5 5.7 2.6 217 9 205 305 8.6 0 9.2 8.4 06/27/2005 15:00:00 4.3 0.6 5.7 2.6 4.2 0.6 5.7 2.3 218 12 233 305 8.7 0 9.2 8.4 06/27/2005 15:10:00 4.2 0.7 6.5 2.6 4.2 0.6 6.5 2.6 219 12 222 305 8.9 0.1 9.2 8.9 06/27/2005 15:20:00 4.4 0.6 6.1 3 4.4 0.6 6.5 3 221 11 230 305 9.1 0 9.5 8.9 06/27/2005 15:30:00 4.3 0.7 6.1 2.3 4.2 0.7 6.1 2.3 223 11 236 305 9.2 0 9.5 9.2 06/27/2005 15:40:00 4.4 0.7 6.1 1.9 4.2 0.6 6.1 2.3 227 14 258 305 9.7 0.1 10 9.5 06/27/2005 15:50:00 4.6 0.9 7.2 1.9 4.5 0.9 6.5 1.1 232 15 226 305 10.1 0 10.2 10 06/27/2005 16:00:00 4 0.8 6.5 1.9 3.8 0.8 6.1 1.5 227 21 227 305 10 0.1 10.2 9.7 06/27/2005 16:10:00 4 0.9 6.5 1.5 3.8 0.9 6.1 1.1 231 22 221 305 10.3 0 10.5 10.2 06/27/2005 16:20:00 4.1 0.9 7.2 1.9 4.1 0.9 6.1 2.3 235 17 227 305 10.4 0 10.8 10.2 06/27/2005 16:30:00 3.7 0.9 6.5 0.7 3.7 0.9 6.5 1.1 229 22 238 305 10.2 0.1 10.8 10 06/27/2005 16:40:00 3.7 0.7 5.7 1.9 3.8 0.7 5.7 1.5 205 19 218 305 9.8 0.1 10.2 9.5 06/27/2005 16:50:00 3.6 0.7 5.3 1.5 3.5 0.8 5.3 1.5 218 17 228 305 9.3 0 9.7 9.2 06/27/2005 17:00:00 3.5 1 6.8 1.1 3.4 0.8 6.5 1.5 223 23 260 305 9.3 0 9.7 9.2 06/27/2005 17:10:00 3.4 0.9 6.5 1.5 3.3 0.8 5.7 1.1 231 17 258 305 9.7 0.2 10 9.2 06/27/2005 17:20:00 3.6 0.9 6.1 1.5 3.4 0.8 5.3 1.1 249 20 281 305 10 0.1 10.2 9.7 06/27/2005 17:30:00 4.7 1 8 1.9 4.4 0.9 6.8 1.5 259 20 266 305 9.9 0.1 10.2 9.7 06/27/2005 17:40:00 4.9 1.2 8 1.5 4.3 1 6.8 2.3 266 17 273 305 9.5 0 9.7 9.5 06/27/2005 17:50:00 4.7 1 7.2 2.6 4.2 1 7.6 1.9 260 15 281 305 9.3 0 9.5 9.2 06/27/2005 18:00:00 4.4 1.2 8 1.1 4.1 1 7.6 1.5 257 17 255 305 9 0 9.2 8.9 06/27/2005 18:10:00 4.9 1.3 8.8 2.3 4.3 1 8.4 1.9 262 17 266 305 9.1 0 9.5 8.9 06/27/2005 18:20:00 5.5 1.1 8 2.6 4.4 1 7.2 2.3 268 15 267 305 9.3 0 9.5 9.2 06/27/2005 18:30:00 6.2 1.1 9.5 2.6 5 1 7.6 2.6 268 14 272 305 9.2 0 9.5 9.2 06/27/2005 18:40:00 6 1.1 8.8 3.4 4.9 1 7.2 2.6 264 11 268 305 9 0 9.2 8.9 06/27/2005 18:50:00 5 1 7.6 2.6 4.6 0.9 6.8 2.6 253 12 261 305 8.9 0.2 9.2 8.7 06/27/2005 19:00:00 4.7 0.8 6.5 3 4.6 0.7 6.8 3 244 11 243 305 8.9 0 9.2 8.9 06/27/2005 19:10:00 4.2 0.8 6.8 2.3 4 0.7 5.7 2.3 233 14 236 305 9.1 0 9.2 8.9 06/27/2005 19:20:00 4.2 0.6 6.1 2.6 4 0.6 6.1 2.6 226 12 232 305 8.9 0 9.2 8.4 06/27/2005 19:30:00 4.4 0.6 6.1 3 4.4 0.6 6.1 2.6 224 11 233 305 8.7 0 8.9 8.2 06/27/2005 19:40:00 4.4 0.6 5.7 2.6 4.3 0.5 5.7 3 229 13 244 305 8.8 0 9.2 8.4 06/27/2005 19:50:00 4.5 0.5 6.1 3 4.4 0.5 5.7 2.6 231 9 238 305 8.8 0.1 9.2 8.4 06/27/2005 20:00:00 4.5 0.6 6.5 2.3 4.4 0.5 5.7 3 235 11 251 305 8.7 0 8.9 8.7 06/27/2005 20:10:00 4.6 0.7 6.5 3 4.5 0.7 6.1 3 239 11 246 305 8.7 0 8.9 8.7 06/27/2005 20:20:00 4.4 0.6 6.5 3 4.3 0.6 6.1 2.6 237 11 245 305 8.7 0 8.9 8.7 06/27/2005 20:30:00 4.4 0.8 6.8 2.6 4.3 0.6 6.8 2.6 238 11 256 305 8.5 0 8.7 8.4 06/27/2005 20:40:00 4.9 0.7 6.5 3.4 4.7 0.7 6.5 3 246 11 262 305 8.5 0 8.9 8.2 06/27/2005 20:50:00 4.9 0.7 6.8 3 4.7 0.7 6.8 3 243 9 242 305 8.4 0 8.4 8.2 06/27/2005 21:00:00 5 0.6 6.5 3.4 4.9 0.6 6.5 3.4 241 8 254 305 8.4 0 8.4 8.2 06/27/2005 21:10:00 5.3 0.7 7.2 3.4 5 0.6 6.8 3.8 240 8 244 305 8.4 0 8.4 8.2 06/27/2005 21:20:00 5 0.6 6.8 3.4 4.9 0.5 6.5 3.4 239 8 238 305 8.4 0 8.4 8.2 06/27/2005 21:30:00 5.3 0.7 7.2 3.4 5 0.6 6.5 3.4 236 7 227 305 8.2 0 8.4 8.2 06/27/2005 21:40:00 5.3 0.6 6.5 3.8 5.1 0.6 6.8 3.4 234 8 250 305 8.2 0 8.2 8.2 06/27/2005 21:50:00 5.3 0.6 6.8 3.8 5.1 0.6 6.5 3.8 231 8 235 305 8.1 0 8.2 7.9 06/27/2005 22:00:00 5.1 0.5 6.5 3.8 4.9 0.5 6.5 3.8 227 7 231 305 8.1 0 8.2 8.2 06/27/2005 22:10:00 5.3 0.5 6.8 3.8 5 0.5 6.5 3.4 225 6 215 305 8 0 8.2 7.9 06/27/2005 22:20:00 5.4 0.5 7.2 3.8 5.2 0.6 6.8 3.8 225 7 215 305 7.9 0 7.9 7.7 06/27/2005 22:30:00 5.4 0.5 6.8 4.2 5.2 0.5 6.5 3.8 223 7 227 305 7.8 0 7.9 7.7 06/27/2005 22:40:00 5.5 0.6 6.8 3.8 5.1 0.6 6.8 3.4 218 8 223 305 7.7 0 7.7 7.7 06/27/2005 22:50:00 5.3 0.6 7.6 3.4 5.1 0.6 7.2 3.8 217 8 214 305 7.6 0 7.7 7.7 06/27/2005 23:00:00 5.1 0.6 6.8 3.4 4.9 0.6 6.8 3.4 216 8 220 305 7.5 0 7.7 7.4 06/27/2005 23:10:00 5.5 0.6 6.8 3.8 5.2 0.6 6.5 3.8 215 7 212 305 7.5 0 7.7 7.4 06/27/2005 23:20:00 5.4 0.6 6.8 3.4 5.1 0.6 6.8 3.4 217 8 217 305 7.4 0 7.7 7.4 06/27/2005 23:30:00 5.2 0.5 7.2 3.8 5.1 0.5 7.2 3.4 213 8 220 305 7.3 0 7.4 7.2 06/27/2005 23:40:00 5 0.6 6.5 3.4 5 0.5 6.5 3.4 210 7 219 305 7.3 0 7.4 7.2 06/27/2005 23:50:00 5.9 0.5 7.2 4.6 5.9 0.5 7.2 4.2 211 7 198 305 7.2 0 7.4 7.2 06/28/2005 00:00:00 6.2 0.6 8 4.9 6 0.6 7.6 4.6 213 7 210 305 7.1 0 7.4 7.2 06/28/2005 00:10:00 6.1 0.5 7.6 4.6 6.1 0.5 7.2 4.9 211 7 212 305 7 0 7.2 7.2 06/28/2005 00:20:00 5.8 0.5 7.6 4.6 5.7 0.5 7.2 4.6 212 7 205 305 7 0 7.2 7.2 06/28/2005 00:30:00 5.7 0.6 7.6 4.2 5.7 0.5 6.8 4.6 209 8 218 305 7 0 7.2 6.9 06/28/2005 00:40:00 6 0.6 8 4.2 6 0.6 7.6 4.6 210 8 217 305 7 0 7.2 6.9 06/28/2005 00:50:00 6.1 0.6 8.4 4.6 6 0.6 7.6 4.2 211 8 218 305 7 0 7.2 6.9 06/28/2005 01:00:00 5.9 0.6 7.6 4.2 5.7 0.5 7.2 4.2 215 8 230 305 7 0 7.2 6.9 06/28/2005 01:10:00 6.5 0.6 8 4.9 6 0.6 7.6 4.6 218 7 210 305 6.8 0 7.2 6.9 06/28/2005 01:20:00 6.5 0.5 7.6 4.9 6.2 0.6 7.6 4.6 219 6 221 305 6.8 0 6.9 6.7 06/28/2005 01:30:00 6.5 0.6 8 4.6 6 0.7 7.6 4.2 218 7 218 305 6.9 0 7.2 6.9 06/28/2005 01:40:00 6.7 0.5 8 4.9 6.4 0.6 7.6 4.6 220 7 232 305 6.9 0 7.2 6.9 06/28/2005 01:50:00 6.6 0.5 8 4.9 6.3 0.5 7.6 4.9 223 6 224 305 6.8 0 6.9 6.7 06/28/2005 02:00:00 6.4 0.6 8.4 4.9 6 0.6 7.6 4.6 224 6 234 305 6.8 0 6.9 6.9 06/28/2005 02:10:00 6.3 0.6 7.6 4.9 5.9 0.5 7.6 4.6 226 6 230 305 6.8 0 6.9 6.9 06/28/2005 02:20:00 6.6 0.6 8 4.6 6.1 0.6 7.6 4.2 232 6 236 305 6.8 0 6.9 6.9 06/28/2005 02:30:00 6.5 0.6 8.4 4.9 6.1 0.6 7.6 4.6 234 6 243 305 6.8 0 6.9 6.9 06/28/2005 02:40:00 6.8 0.6 8 4.9 6.3 0.6 7.6 4.9 233 6 246 305 6.9 0 7.2 6.9 06/28/2005 02:50:00 6.7 0.6 8.4 4.9 6.2 0.6 8.4 4.9 236 7 231 305 6.9 0 7.2 6.9 06/28/2005 03:00:00 6.8 0.7 8.4 4.9 5.9 0.7 8 4.2 238 7 235 305 7 0 7.2 6.9 06/28/2005 03:10:00 6.8 0.7 8.8 4.9 6.1 0.7 8 4.6 238 7 245 305 7 0 7.2 6.9 06/28/2005 03:20:00 7.1 0.7 8.8 4.9 6.4 0.7 8.4 4.6 238 6 232 305 7 0 7.2 6.9 06/28/2005 03:30:00 7.1 0.7 9.1 4.9 6.3 0.8 8.4 4.2 239 7 244 305 7 0 7.4 6.9 06/28/2005 03:40:00 7 0.8 9.5 4.6 6.3 0.9 8.8 4.2 240 7 242 305 7 0 7.2 6.9 06/28/2005 03:50:00 6.3 0.6 8.4 4.6 5.5 0.7 7.6 3.8 240 7 238 305 7 0 7.2 6.9 06/28/2005 04:00:00 6.6 0.6 8.4 4.9 5.7 0.7 7.6 3.8 240 7 244 305 7 0 7.4 6.9 06/28/2005 04:10:00 6.6 0.8 8.4 4.2 5.8 0.8 8 3.8 239 7 245 305 7 0 7.4 6.9 06/28/2005 04:20:00 6.6 0.7 8.8 4.9 5.9 0.7 8 4.2 239 8 250 305 7 0 7.4 7.2 06/28/2005 04:30:00 7.2 0.7 8.8 4.9 6.4 0.8 8.4 4.2 243 7 238 305 7.1 0.1 7.7 6.9 06/28/2005 04:40:00 7.1 0.7 8.8 4.9 6.2 0.8 8.4 4.6 247 8 242 305 7 0 7.7 7.2 06/28/2005 04:50:00 6.9 0.7 8.8 5.3 6 0.8 8 4.2 248 8 255 305 7.1 0.1 7.7 7.2 06/28/2005 05:00:00 6.8 0.7 8.8 4.9 6 0.8 8.4 4.2 247 8 268 305 7 0 7.7 7.2 06/28/2005 05:10:00 6.5 0.8 8.4 4.6 5.8 0.9 8.4 3.8 249 9 255 305 7 0 7.7 7.2 06/28/2005 05:20:00 7.2 0.9 9.5 4.6 6.5 1 9.1 4.2 249 8 253 305 7.1 0.1 7.7 7.2 06/28/2005 05:30:00 7.6 1 9.9 4.9 6.7 1 9.1 4.2 249 8 260 305 7.2 0.1 7.7 7.2 06/28/2005 05:40:00 7.8 0.8 10.3 5.3 6.9 0.9 9.5 4.2 251 7 257 305 7.2 0.1 7.7 7.2 06/28/2005 05:50:00 7.4 1 9.9 4.9 6.6 0.9 8.8 3.8 254 9 266 305 7.3 0 7.9 7.2 06/28/2005 06:00:00 6.9 0.9 9.5 4.9 5.9 0.8 8.8 3.8 256 9 253 305 7.5 0 7.9 7.4 06/28/2005 06:10:00 7.2 0.9 9.1 4.6 6.2 0.9 8.4 3.8 255 8 256 305 7.5 0 8.2 7.4 06/28/2005 06:20:00 6.8 0.8 9.1 4.9 6.1 0.9 8.8 4.2 255 9 246 305 7.6 0 8.2 7.4 06/28/2005 06:30:00 6.3 0.9 8 4.2 5.6 1 8 3.4 253 10 244 305 7.7 0 7.9 7.7 06/28/2005 06:40:00 6.3 0.9 8.4 3.8 5.6 0.9 8 3.4 252 9 258 305 7.9 0 8.2 7.7 06/28/2005 06:50:00 6.4 0.9 8.4 4.2 5.9 0.8 8 3.4 248 9 252 305 7.8 0 7.9 7.7 06/28/2005 07:00:00 6.6 0.8 8.8 4.6 5.7 0.9 8 3.8 251 9 254 305 7.9 0 8.2 7.7 06/28/2005 07:10:00 6 0.9 8.8 3.4 5.5 0.9 7.6 3 252 10 250 305 7.9 0 8.2 7.7 06/28/2005 07:20:00 6.3 0.9 9.1 3.8 5.8 0.9 8 3 250 9 253 305 7.9 0 8.4 7.9 06/28/2005 07:30:00 6.1 1 8.4 3 5.4 0.9 8 3 250 10 259 305 8 0 8.2 7.9 06/28/2005 07:40:00 6 0.9 8.4 3.8 5.2 1 8 2.6 253 11 256 305 8.1 0 8.4 7.9 06/28/2005 07:50:00 5.6 0.8 7.6 3.4 5 0.8 8 3 253 11 256 305 8 0 8.4 7.9 06/28/2005 08:00:00 5.4 0.8 7.6 3.4 4.9 0.8 6.8 3.4 249 10 255 305 8 0 8.4 7.9 06/28/2005 08:10:00 5.2 0.8 7.2 3.4 4.9 0.7 6.8 2.6 246 10 265 305 8 0 8.4 7.9 06/28/2005 08:20:00 5.5 0.9 8.4 3.8 5 0.8 7.2 3 248 10 261 305 8.1 0 8.7 7.9 06/28/2005 08:30:00 5.6 1 8 3.4 5.1 0.9 8 3 252 10 245 305 8.1 0 8.7 7.9 06/28/2005 08:40:00 5.4 1 8 3 4.9 0.9 7.6 3 254 11 253 305 8.2 0 8.7 7.9 06/28/2005 08:50:00 5.4 0.9 7.2 3 4.7 1 7.6 2.6 261 11 281 305 8.1 0 8.7 8.2 06/28/2005 09:00:00 5.5 1 7.6 2.6 4.9 0.9 7.2 2.6 261 12 242 305 8.3 0.1 8.9 8.2 06/28/2005 09:10:00 5.9 1 8.4 3.8 5.1 1 8 2.3 262 11 262 305 8.3 0 8.7 8.2 06/28/2005 09:20:00 5.4 1 8.8 3 4.6 0.8 6.5 2.6 264 12 275 305 8.4 0 8.9 8.2 06/28/2005 09:30:00 5.3 1 7.6 2.6 4.7 1 7.2 3 261 11 258 305 8.5 0 9.2 8.2 06/28/2005 09:40:00 4.7 1.1 8 2.3 4.2 0.8 6.8 2.6 257 12 263 305 8.8 0.1 9.2 8.7 06/28/2005 09:50:00 4.8 0.8 7.2 2.6 4.4 0.8 6.5 2.6 257 13 275 305 8.8 0 9.2 8.4 06/28/2005 10:00:00 4.4 0.9 6.8 2.3 4.1 0.8 6.8 2.3 255 12 262 305 8.8 0 9.2 8.7 06/28/2005 10:10:00 4.1 0.9 6.1 1.9 3.8 0.8 5.7 1.9 254 14 262 305 8.8 0.1 9.5 8.7 06/28/2005 10:20:00 4.5 0.9 6.8 1.9 4.1 0.7 6.8 2.3 257 13 266 305 8.9 0 9.2 8.7 06/28/2005 10:30:00 5 0.9 7.6 3 4.4 0.8 6.8 2.6 257 12 270 305 8.9 0 9.2 8.9 06/28/2005 10:40:00 5.2 1.1 8.8 3 4.5 0.9 6.8 2.3 261 13 248 305 9.1 0 9.5 8.9 06/28/2005 10:50:00 4.9 1 6.8 1.9 4.2 0.9 6.5 2.3 262 14 280 305 9.2 0 9.5 9.2 06/28/2005 11:00:00 5 0.9 7.2 3 4.4 0.9 6.5 2.3 264 14 276 305 9.3 0 9.5 9.2 06/28/2005 11:10:00 4.8 1 7.2 2.3 4 1 6.5 1.9 263 14 275 305 9.3 0.1 9.7 9.2 06/28/2005 11:20:00 4.9 1.1 8 2.3 4.1 1 6.8 2.3 270 13 275 305 9.6 0 9.7 9.5 06/28/2005 11:30:00 4.7 1.2 8.8 1.5 4.2 0.9 6.8 1.9 267 14 273 305 9.5 0 9.7 9.5 06/28/2005 11:40:00 4.5 1 6.8 2.6 4 0.8 6.1 1.9 264 13 273 305 9.5 0.1 9.7 9.2 06/28/2005 11:50:00 4.6 1 7.6 2.3 4.1 0.8 5.7 1.9 263 15 268 305 9.8 0.1 10.2 9.5 06/28/2005 12:00:00 4.4 1 7.2 2.3 3.8 0.9 6.5 1.9 264 16 291 305 9.9 0 10.2 9.7 06/28/2005 12:10:00 4.1 1 6.8 1.5 3.6 0.8 6.1 1.5 261 15 262 305 9.9 0 10.2 9.7 06/28/2005 12:20:00 4.5 0.9 7.2 2.3 4 0.9 6.5 2.3 259 15 269 305 9.9 0 10.2 9.7 06/28/2005 12:30:00 4.1 1 6.8 1.9 3.9 0.9 6.5 1.9 260 17 256 305 9.8 0 10 9.7 06/28/2005 12:40:00 4.1 1 7.2 2.3 3.7 0.8 5.7 1.5 261 15 261 305 9.8 0 10 9.7 06/28/2005 12:50:00 4 1 6.5 1.1 3.5 0.8 5.7 1.9 257 17 252 305 10.2 0 10.2 10 06/28/2005 13:00:00 3.7 0.8 6.1 1.1 3.4 0.7 5.3 1.5 256 20 285 305 10.4 0.1 10.8 10.2 06/28/2005 13:10:00 3.9 0.9 6.5 1.9 3.6 0.8 6.1 1.5 250 17 256 305 10.2 0 10.5 10.2 06/28/2005 13:20:00 3.9 1 7.2 1.9 3.7 0.9 6.1 1.9 252 17 264 305 10.3 0 10.5 10 06/28/2005 13:30:00 4.1 0.8 6.5 1.9 3.7 0.8 6.1 1.9 254 18 250 305 10.4 0 10.8 10.2 06/28/2005 13:40:00 4.1 1 7.6 1.5 3.8 0.9 6.5 1.9 246 18 266 305 10.6 0 10.8 10.5 06/28/2005 13:50:00 3.8 0.8 6.1 1.9 3.7 0.7 6.5 2.3 242 18 243 305 10.7 0.1 11 10.5 06/28/2005 14:00:00 3.9 1 6.5 1.1 3.8 0.8 6.5 1.9 243 20 244 305 10.6 0.2 11 10.2 06/28/2005 14:10:00 4.2 0.8 6.5 2.3 3.8 0.8 5.7 2.3 246 17 257 305 10.8 0 11 10.5 06/28/2005 14:20:00 4 0.9 6.8 1.5 3.9 0.8 6.1 1.9 235 16 254 305 10.7 0 10.8 10.2 06/28/2005 14:30:00 4.1 0.9 6.5 1.5 4 0.8 6.8 1.9 243 16 221 305 10.5 0 10.8 10.2 06/28/2005 14:40:00 4.6 0.8 7.2 2.3 4.6 0.8 7.2 2.3 243 15 246 305 10.2 0 10.2 10 06/28/2005 14:50:00 4.5 0.9 6.8 1.5 4.3 0.8 6.5 2.3 242 16 256 305 10.7 0 10.8 10.2 06/28/2005 15:00:00 4.4 0.8 6.8 2.6 4.4 0.8 7.2 2.3 238 15 256 305 10.5 0.1 10.8 10.2 06/28/2005 15:10:00 4.3 0.9 8 1.9 4.1 0.8 6.8 1.5 235 15 252 305 10.4 0.1 10.8 10.2 06/28/2005 15:20:00 4.2 0.8 6.5 1.9 4.2 0.7 6.5 2.3 235 16 244 305 10.5 0.1 11 10.2 06/28/2005 15:30:00 4.2 0.8 6.5 2.3 4.1 0.7 5.7 2.3 232 16 258 305 10.6 0.1 10.8 10.2 06/28/2005 15:40:00 4.6 0.8 7.2 2.6 4.4 0.8 6.8 2.3 236 17 260 305 10.4 0 10.8 10.2 06/28/2005 15:50:00 5 0.9 7.2 3 4.7 0.8 6.8 2.3 250 13 251 305 10.2 0 10.5 10 06/28/2005 16:00:00 4.9 0.9 7.6 2.6 4.7 0.8 7.2 2.6 251 12 255 305 10.4 0.1 10.8 10 06/28/2005 16:10:00 4.8 1 7.2 2.3 4.6 0.9 7.2 2.6 252 13 245 305 10.2 0 10.5 10 06/28/2005 16:20:00 4.8 1 7.2 2.6 4.5 1 7.2 2.3 250 13 254 305 10.3 0 10.5 10.2 06/28/2005 16:30:00 5.3 0.9 8 3 4.9 0.9 7.6 2.3 252 12 263 305 10.3 0 10.5 10 06/28/2005 16:40:00 5.2 0.9 8.4 2.6 4.8 0.9 7.6 2.6 253 13 251 305 10.2 0 10.5 10 06/28/2005 16:50:00 5.6 1 8.4 2.6 5.2 0.8 7.2 3 250 12 239 305 10.3 0 10.5 10.2 06/28/2005 17:00:00 5.4 1 8 3.4 5.2 1 7.6 3 247 11 246 305 10.4 0 10.8 10.2 06/28/2005 17:10:00 5.6 1 8.4 3 5.3 0.8 7.6 3 249 11 250 305 10.3 0 10.5 10.2 06/28/2005 17:20:00 5.9 1 8.8 3.8 5.6 1.1 9.1 2.3 253 12 259 305 10.3 0 10.5 10 06/28/2005 17:30:00 6.5 1 9.1 3.4 6 1 8.8 3.8 254 10 262 305 10.3 0 10.5 10.2 06/28/2005 17:40:00 6.3 1 9.1 3.8 5.8 1 8.4 3.4 252 10 257 305 10.6 0 10.8 10.2 06/28/2005 17:50:00 6.3 0.9 8.8 4.2 5.9 1 8.4 3.8 251 11 256 305 10.3 0 10.5 10.2 06/28/2005 18:00:00 5.7 1 8.4 3.4 5.4 0.9 8 3 246 11 251 305 10.1 0 10.2 10 06/28/2005 18:10:00 5.3 0.8 8 3 5.1 0.8 7.2 3.4 237 12 242 305 10.2 0 10.5 10.2 06/28/2005 18:20:00 5.1 0.6 6.8 3.4 4.9 0.6 6.5 3.4 227 10 238 305 10.2 0.2 10.5 9.7 06/28/2005 18:30:00 5 0.5 6.5 3.4 4.7 0.6 6.1 3.4 219 10 213 305 10 0 10.2 9.7 06/28/2005 18:40:00 4.8 0.7 6.8 3 4.8 0.7 6.8 3.4 216 12 225 305 9.7 0 10 9.5 06/28/2005 18:50:00 4.8 0.7 6.5 3 4.7 0.7 6.5 3 218 11 218 305 9.8 0 10 9.7 06/28/2005 19:00:00 4.7 0.6 6.5 3 4.7 0.5 6.1 3 223 10 231 305 9.8 0 10 9.7 06/28/2005 19:10:00 4.6 0.7 6.1 3 4.5 0.6 6.1 3 223 10 227 305 9.8 0 10 9.7 06/28/2005 19:20:00 4.8 0.7 6.8 3 4.7 0.6 6.1 2.6 222 10 231 305 9.7 0 10 9.5 06/28/2005 19:30:00 4.9 0.6 7.2 2.3 4.7 0.6 6.1 2.6 220 10 237 305 9.7 0 9.7 9.7 06/28/2005 19:40:00 5 0.7 6.8 3.4 4.9 0.6 6.8 3.4 226 11 238 305 9.7 0 9.7 9.5 06/28/2005 19:50:00 5.2 0.7 6.8 3.4 5 0.6 6.8 3.4 222 9 242 305 9.7 0 9.7 9.5 06/28/2005 20:00:00 5.4 0.7 7.2 3.4 5.2 0.7 6.8 3 218 9 225 305 9.5 0.1 9.7 9.2 06/28/2005 20:10:00 5.2 0.7 6.8 3.4 4.9 0.7 6.5 3.4 224 9 239 305 9.4 0 9.7 9.2 06/28/2005 20:20:00 5.6 0.8 7.6 3.8 5.2 0.7 7.6 3.4 229 10 247 305 9.3 0 9.5 9.2 06/28/2005 20:30:00 5.4 0.8 7.6 3.8 5.1 0.7 7.2 3 229 10 238 305 9.4 0 9.5 9.2 06/28/2005 20:40:00 5.2 0.6 7.6 3.8 4.9 0.6 7.6 3.4 227 9 239 305 9.2 0 9.5 9.2 06/28/2005 20:50:00 5.4 0.8 7.2 3.4 5 0.7 6.5 3.4 236 11 250 305 9.2 0 9.5 9.2 06/28/2005 21:00:00 5.3 0.9 7.6 3.4 4.8 0.8 7.2 3 243 11 236 305 9.4 0 9.7 9.2 06/28/2005 21:10:00 5.3 0.8 8 3 4.7 0.8 6.8 2.6 248 11 255 305 9.3 0 9.5 9.2 06/28/2005 21:20:00 5.2 1 7.6 3 4.9 0.9 8 3 241 11 236 305 9.2 0 9.5 9.2 06/28/2005 21:30:00 4.7 0.7 6.8 3 4.5 0.6 6.5 3 232 11 221 305 9.2 0 9.2 9.2 06/28/2005 21:40:00 4.5 0.7 6.5 3 4.4 0.6 5.7 2.6 222 11 224 305 9.1 0 9.2 8.9 06/28/2005 21:50:00 4.3 0.7 6.5 2.6 4.3 0.6 6.5 2.6 211 11 218 305 8.9 0 9.2 8.7 06/28/2005 22:00:00 4.4 0.6 6.5 2.6 4.6 0.6 6.5 3.4 198 11 190 305 8.8 0 8.9 8.9 06/28/2005 22:10:00 4.5 0.6 6.1 2.3 4.6 0.7 6.8 3 199 13 199 305 8.9 0 9.2 8.9 06/28/2005 22:20:00 4.9 0.7 6.5 3 5 0.7 6.5 3.8 202 12 217 305 9 0 9.2 8.9 06/28/2005 22:30:00 5.9 0.8 7.6 3.8 5.9 0.8 8.8 3.8 207 11 191 305 8.8 0 9.2 8.7 06/28/2005 22:40:00 5.8 0.7 8 3.4 5.8 0.8 8 3.4 213 9 222 305 8.6 0 8.7 8.4 06/28/2005 22:50:00 5.8 0.7 7.6 4.2 5.8 0.6 7.6 4.2 211 7 217 305 8.4 0 8.7 8.2 06/28/2005 23:00:00 6.2 0.6 8 4.6 6.3 0.6 8 4.9 208 7 222 305 8.2 0 8.4 8.2 06/28/2005 23:10:00 6.2 0.7 8 4.6 6.3 0.6 8 4.6 207 7 211 305 8.1 0 8.2 7.9 06/28/2005 23:20:00 6.2 0.6 7.6 4.9 6.2 0.6 7.6 4.6 206 9 208 305 8 0 8.2 7.9 06/28/2005 23:30:00 6.2 0.7 7.6 4.6 6.2 0.6 7.6 4.6 204 9 208 305 7.9 0 7.9 7.9 06/28/2005 23:40:00 6.4 0.6 8.8 4.9 6.6 0.6 8.4 4.9 205 7 212 305 7.8 0 7.9 7.7 06/28/2005 23:50:00 6.5 0.8 8.8 4.9 6.7 0.7 8.8 4.6 207 8 219 305 7.6 0 7.7 7.7 06/29/2005 00:00:00 6.2 0.6 7.6 4.2 6.3 0.6 8 4.6 206 8 208 305 7.5 0 8.2 7.4 06/29/2005 00:10:00 6.2 0.6 8 4.6 6.1 0.7 8.4 4.6 207 9 208 305 7.5 0 7.7 7.4 06/29/2005 00:20:00 6.3 0.6 8 4.9 6.5 0.5 8 4.9 207 8 192 305 7.5 0 7.7 7.4 06/29/2005 00:30:00 6.2 0.6 7.6 4.6 6.4 0.6 8 4.6 208 8 210 305 7.4 0 7.7 7.4 06/29/2005 00:40:00 6.2 0.6 7.6 4.6 6.3 0.6 7.6 4.9 208 6 224 305 7.4 0 7.7 7.4 06/29/2005 00:50:00 6.1 0.6 8 4.6 6.1 0.6 8 4.2 210 8 221 305 7.4 0 7.7 7.4 06/29/2005 01:00:00 5.8 0.5 7.2 4.6 5.9 0.5 7.2 4.6 213 7 213 305 7.3 0 7.4 7.4 06/29/2005 01:10:00 5.7 0.5 7.2 4.2 5.7 0.5 7.2 4.6 209 8 217 305 7.3 0 7.4 7.4 06/29/2005 01:20:00 5.5 0.5 6.8 4.2 5.5 0.6 7.2 4.2 207 8 205 305 7.3 0 7.4 7.4 06/29/2005 01:30:00 5.4 0.5 6.8 4.2 5.3 0.5 6.8 3.8 207 8 198 305 7.5 0 7.7 7.4 06/29/2005 01:40:00 5.6 0.6 8 4.2 5.6 0.7 8.4 3.8 208 9 214 305 7.5 0 7.7 7.4 06/29/2005 01:50:00 5.6 0.6 7.2 4.2 5.6 0.6 6.8 4.2 208 9 230 305 7.5 0 7.7 7.4 06/29/2005 02:00:00 6 0.6 7.6 4.6 5.9 0.6 8.4 4.2 205 7 208 305 7.5 0 7.7 7.4 06/29/2005 02:10:00 6 0.6 7.6 4.6 5.9 0.5 8 4.9 208 8 206 305 7.5 0 7.7 7.4 06/29/2005 02:20:00 6 0.6 7.6 4.6 6.1 0.5 7.6 4.2 208 7 217 305 7.3 0 7.7 7.4 06/29/2005 02:30:00 6 0.5 7.6 4.6 6 0.6 8 4.2 208 8 205 305 7.3 0 7.4 7.2 06/29/2005 02:40:00 5.8 0.6 7.2 4.2 5.8 0.5 7.2 4.2 209 8 202 305 7.3 0 7.4 7.2 06/29/2005 02:50:00 6 0.5 7.2 4.6 5.7 0.5 6.8 4.2 213 7 208 305 7.3 0 7.4 7.2 06/29/2005 03:00:00 6 0.6 7.6 4.6 5.8 0.6 8 4.2 216 7 224 305 7.2 0 7.7 7.2 06/29/2005 03:10:00 5.7 0.5 7.2 4.2 5.6 0.5 7.2 4.2 215 7 223 305 7.2 0 7.7 7.2 06/29/2005 03:20:00 5.9 0.6 7.2 4.2 5.6 0.6 6.8 3.8 215 7 209 305 7.3 0 7.7 7.2 06/29/2005 03:30:00 5.9 0.5 7.6 4.6 5.6 0.6 7.2 3.4 215 8 223 305 7.3 0 7.7 7.2 06/29/2005 03:40:00 6.1 0.5 7.2 4.2 6 0.5 7.6 4.2 213 7 209 305 7.3 0 7.7 7.2 06/29/2005 03:50:00 6.1 0.5 7.6 4.6 5.9 0.6 7.2 4.6 213 6 220 305 7.2 0.1 7.7 7.2 06/29/2005 04:00:00 6 0.6 7.2 4.2 5.6 0.6 6.8 4.2 217 7 216 305 7.2 0.1 7.7 7.2 06/29/2005 04:10:00 5.9 0.6 7.2 4.2 5.7 0.6 7.2 4.2 215 7 217 305 7.2 0.1 7.7 7.2 06/29/2005 04:20:00 6.1 0.5 7.2 4.9 6.1 0.5 7.6 4.6 206 7 213 305 7.3 0.1 7.7 7.2 06/29/2005 04:30:00 6.6 0.5 8.4 5.3 6.6 0.6 8.4 5.3 204 7 199 305 7.3 0 7.9 7.2 06/29/2005 04:40:00 6.6 0.5 7.6 5.3 6.6 0.5 8 5.3 203 6 204 305 7.3 0.1 7.9 7.4 06/29/2005 04:50:00 6.6 0.5 7.6 5.3 6.6 0.5 8 5.3 206 6 210 305 7.3 0.1 7.9 7.4 06/29/2005 05:00:00 6.4 0.5 7.6 5.3 6.5 0.5 8 4.9 210 6 205 305 7.3 0.1 7.9 7.4 06/29/2005 05:10:00 6.1 0.5 7.6 4.6 6.1 0.5 7.2 4.9 211 6 219 305 7.3 0 7.9 7.4 06/29/2005 05:20:00 5.9 0.6 7.6 4.2 5.8 0.6 7.2 4.2 213 7 218 305 7.3 0 7.7 7.4 06/29/2005 05:30:00 5.6 0.6 6.8 3.8 5.4 0.6 6.5 3.8 217 7 220 305 7.4 0 7.7 7.4 06/29/2005 05:40:00 5.7 0.5 6.8 3.8 5.4 0.6 6.8 3.8 218 7 219 305 7.5 0 7.7 7.4 06/29/2005 05:50:00 6.1 0.6 8 3.8 5.9 0.6 7.2 4.2 214 6 218 305 7.5 0 7.7 7.7 06/29/2005 06:00:00 6 0.5 7.2 4.6 5.9 0.6 7.2 4.2 213 7 221 305 7.5 0 7.7 7.4 06/29/2005 06:10:00 5.7 0.5 6.8 4.2 5.5 0.5 6.8 3.8 219 8 218 305 7.6 0 7.7 7.7 06/29/2005 06:20:00 5.6 0.5 7.2 4.2 5.4 0.5 6.5 4.2 224 8 227 305 7.7 0 7.9 7.7 06/29/2005 06:30:00 6.2 0.5 7.6 4.6 5.8 0.5 7.2 4.2 224 7 237 305 7.9 0 7.9 7.9 06/29/2005 06:40:00 6.3 0.6 7.6 4.6 6 0.6 7.2 4.6 220 7 231 305 7.9 0 7.9 7.9 06/29/2005 06:50:00 6 0.6 7.6 4.6 5.7 0.6 7.6 4.2 218 7 219 305 8 0 8.4 7.9 06/29/2005 07:00:00 6.1 0.5 7.2 4.2 5.9 0.6 7.2 4.6 214 7 222 305 8 0 8.4 7.9 06/29/2005 07:10:00 7 0.6 8.8 4.9 7 0.6 8.4 4.9 209 6 214 305 7.7 0 7.9 7.7 06/29/2005 07:20:00 6.9 0.6 8.4 4.9 6.3 0.6 8 4.6 216 6 216 305 7.7 0 7.9 7.7 06/29/2005 07:30:00 6.8 0.6 8.4 4.6 6.4 0.8 8.4 4.6 213 6 214 305 7.7 0 8.2 7.7 06/29/2005 07:40:00 6.9 0.6 8.4 4.9 6.5 0.7 8.4 4.6 216 6 205 305 7.8 0.1 8.2 7.7 06/29/2005 07:50:00 7 0.6 8.4 5.3 6.7 0.7 8.4 4.6 217 6 216 305 7.7 0.1 8.2 7.7 06/29/2005 08:00:00 6.6 0.6 8 4.6 6.2 0.7 8 4.6 215 6 215 305 7.7 0.1 8.2 7.7 06/29/2005 08:10:00 6.3 0.6 7.6 4.6 6 0.6 8 4.2 215 7 217 305 7.7 0 8.2 7.7 06/29/2005 08:20:00 6.5 0.6 8 4.2 6.1 0.7 7.6 4.2 216 7 218 305 7.8 0 8.4 7.7 06/29/2005 08:30:00 6.5 0.6 8 4.6 6.2 0.7 7.6 4.6 214 6 217 305 7.9 0.1 8.4 7.7 06/29/2005 08:40:00 6.6 0.7 8.4 4.9 6.2 0.7 8 4.2 217 7 216 305 7.9 0 8.4 7.7 06/29/2005 08:50:00 6.4 0.6 8 4.6 6.1 0.7 8 4.2 215 7 220 305 7.9 0 8.4 7.7 06/29/2005 09:00:00 6.6 0.6 8.4 4.9 6.2 0.7 8 4.2 216 6 215 305 8 0 8.7 7.9 06/29/2005 09:10:00 7.3 0.6 9.1 5.7 7.1 0.7 8.8 4.9 216 6 202 305 7.8 0.1 8.4 7.4 06/29/2005 09:20:00 6.8 0.7 8.4 4.9 6.4 0.8 8 4.6 214 6 218 305 7.5 0 7.9 7.4 06/29/2005 09:30:00 6.8 0.8 8.8 4.9 6.5 0.8 8 4.6 214 6 214 305 7.3 0 7.9 7.2 06/29/2005 09:40:00 6.9 0.7 8.4 4.9 6.6 0.9 8.4 4.6 214 6 221 305 7.5 0 8.2 7.4 06/29/2005 09:50:00 7.4 0.5 8.8 5.7 7.2 0.6 8.4 5.7 210 5 209 305 7.5 0 7.9 7.4 06/29/2005 10:00:00 7.3 0.6 8.8 6.1 7.2 0.6 9.1 5.7 208 5 207 305 7.5 0 7.9 7.4 06/29/2005 10:10:00 7 0.5 8.4 5.7 7.1 0.5 8.8 5.7 209 5 210 305 7.4 0 7.9 7.2 06/29/2005 10:20:00 6.7 0.5 8 4.9 6.6 0.6 8 4.6 211 6 212 305 7.5 0 7.9 7.2 06/29/2005 10:30:00 7.6 0.7 9.1 6.1 7.7 0.7 9.1 5.3 208 5 208 305 7.5 0 7.9 7.4 06/29/2005 10:40:00 7.8 0.6 9.5 6.1 7.6 0.7 9.1 5.7 210 5 211 305 7.6 0 7.9 7.4 06/29/2005 10:50:00 7.5 0.6 8.8 6.1 7.5 0.6 8.8 5.3 209 5 208 305 7.5 0 7.9 7.4 06/29/2005 11:00:00 8 0.7 9.5 5.3 7.9 0.7 9.5 5.3 210 5 211 305 7.2 0.1 7.7 7.2 06/29/2005 11:10:00 7.6 0.6 9.1 5.7 7.5 0.7 9.1 5.3 212 5 218 305 7 0 7.7 6.9 06/29/2005 11:20:00 7 0.6 8.4 5.3 6.8 0.7 8.4 4.9 213 6 218 305 7.1 0.1 7.7 6.9 06/29/2005 11:30:00 6.8 0.5 8 5.3 6.7 0.6 8 5.3 211 5 210 305 7 0 7.7 6.9 06/29/2005 11:40:00 7.2 0.5 8.8 5.3 7.1 0.5 8.4 4.9 210 4 214 305 7.2 0.1 7.7 7.2 06/29/2005 11:50:00 7.2 0.7 9.5 4.9 7.1 0.7 9.5 5.3 214 6 214 305 7.4 0 7.9 7.4 06/29/2005 12:00:00 7.4 0.6 8.8 5.7 7.2 0.7 9.1 4.9 218 5 215 305 7.3 0 7.7 7.2 06/29/2005 12:10:00 6.8 0.6 8.4 4.9 6.6 0.8 8.4 4.6 219 6 216 305 7.6 0.1 8.2 7.2 06/29/2005 12:20:00 6.7 0.6 8 4.9 6.6 0.7 8 4.6 220 6 228 305 7.6 0 8.2 7.4 06/29/2005 12:30:00 6.5 0.6 8 4.6 6.4 0.6 8 4.6 222 6 224 305 7.7 0.1 8.2 7.4 06/29/2005 12:40:00 6.4 0.6 8 4.9 6 0.6 8 4.2 223 6 224 305 7.9 0.1 8.4 7.7 06/29/2005 12:50:00 6 0.7 8 4.2 5.9 0.6 7.6 4.2 222 7 223 305 8.1 0.1 8.4 7.7 06/29/2005 13:00:00 5.9 0.7 7.2 4.2 5.8 0.7 7.2 4.2 217 9 223 305 7.9 0.1 8.2 7.4 06/29/2005 13:10:00 6.1 0.8 7.6 3.8 6.1 0.8 7.6 4.2 210 6 213 305 7.7 0 7.9 7.4 06/29/2005 13:20:00 6.7 0.7 8 4.6 6.6 0.7 8 4.6 213 6 214 305 7.5 0 8.2 7.4 06/29/2005 13:30:00 6.7 0.6 8 4.6 6.6 0.7 8 4.2 213 6 215 305 7.5 0 7.9 7.4 06/29/2005 13:40:00 6.3 0.7 8 4.2 6.1 0.7 7.6 4.2 214 7 217 305 7.6 0.1 8.2 7.4 06/29/2005 13:50:00 6.1 0.6 7.6 4.6 6 0.6 7.2 3.8 218 6 227 305 7.6 0 8.2 7.4 06/29/2005 14:00:00 5.9 0.7 7.6 4.2 5.8 0.7 7.6 3.8 218 6 215 305 7.7 0.1 8.2 7.4 06/29/2005 14:10:00 5.9 0.6 7.2 4.6 5.8 0.6 7.2 4.6 218 7 223 305 7.4 0.2 8.2 7.2 06/29/2005 14:20:00 6 0.5 7.6 4.6 5.9 0.6 7.6 4.2 219 6 225 305 7.2 0.1 7.9 7.2 06/29/2005 14:30:00 5.8 0.7 7.6 3.8 5.6 0.7 7.2 3 215 6 218 305 7.2 0.1 7.7 6.9 06/29/2005 14:40:00 5.6 0.7 7.2 3.4 5.5 0.8 7.2 3.4 211 8 214 305 7.4 0 7.7 7.2 06/29/2005 14:50:00 6.1 0.5 7.2 4.2 6.1 0.5 7.6 4.2 210 6 210 305 7 0 7.4 6.9 06/29/2005 15:00:00 6.2 0.5 7.2 4.2 6.1 0.6 7.2 4.2 216 6 217 305 7 0 7.4 6.9 06/29/2005 15:10:00 5.7 0.5 6.8 4.2 5.7 0.6 6.8 3.8 215 5 218 305 6.9 0.1 7.4 6.7 06/29/2005 15:20:00 5.4 0.6 6.8 3.8 5.3 0.7 6.8 3.8 217 7 224 305 7.2 0 7.4 6.9 06/29/2005 15:30:00 5.3 0.5 6.8 3.4 5.3 0.5 6.8 4.2 217 7 221 305 7.1 0.1 7.4 6.9 06/29/2005 15:40:00 5 0.6 6.5 3.4 5 0.7 6.5 3 220 8 213 305 7.5 0 7.7 7.2 06/29/2005 15:50:00 6 0.6 7.6 3.8 5.9 0.6 7.6 4.2 218 8 212 305 7.2 0.1 7.7 7.2 06/29/2005 16:00:00 5.5 0.6 7.2 3.8 5.4 0.7 6.8 3.8 216 8 215 305 7.3 0.2 7.7 7.2 06/29/2005 16:10:00 5.9 0.5 7.2 4.6 5.8 0.6 7.2 3.8 210 8 223 305 7 0 7.4 6.9 06/29/2005 16:20:00 6 0.5 7.2 4.2 5.9 0.5 7.2 4.6 215 6 213 305 6.8 0.1 7.2 6.7 06/29/2005 16:30:00 5.7 0.6 6.8 3.8 5.7 0.5 6.8 4.2 211 6 214 305 6.9 0 7.2 6.7 06/29/2005 16:40:00 5.3 0.5 6.5 4.2 5.2 0.5 6.5 3.4 221 8 237 305 7.2 0.2 7.7 6.7 06/29/2005 16:50:00 5.9 0.6 7.2 4.2 5.7 0.6 7.2 4.2 220 8 214 305 6.9 0.1 7.7 6.7 06/29/2005 17:00:00 6.2 0.5 7.2 4.6 6.1 0.6 7.6 4.6 217 6 228 305 7.1 0.1 7.7 6.9 06/29/2005 17:10:00 5.9 0.5 7.2 4.2 5.9 0.6 7.2 4.2 222 6 221 305 6.9 0 7.4 6.7 06/29/2005 17:20:00 5.6 0.6 7.2 4.2 5.5 0.7 7.6 3.4 222 7 232 305 6.8 0 7.2 6.7 06/29/2005 17:30:00 5.5 0.6 7.2 3.4 5.4 0.6 6.8 3.8 220 8 227 305 6.9 0.1 7.7 6.7 06/29/2005 17:40:00 5.7 0.6 7.2 4.2 5.6 0.6 6.8 3.8 217 7 221 305 6.7 0.1 7.2 6.4 06/29/2005 17:50:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 4.2 223 7 217 305 6.8 0.1 7.4 6.7 06/29/2005 18:00:00 5.7 0.6 7.2 4.2 5.6 0.6 6.8 3.8 213 7 210 305 6.8 0.1 7.4 6.7 06/29/2005 18:10:00 6 0.6 7.6 4.2 6 0.6 7.6 4.2 211 6 208 305 6.7 0.1 7.4 6.4 06/29/2005 18:20:00 6.7 0.6 8.4 4.9 6.6 0.6 8 4.6 211 6 205 305 6.7 0 7.2 6.4 06/29/2005 18:30:00 6.9 0.5 8 5.7 6.8 0.5 8.4 5.3 209 5 208 305 6.5 0 7.2 6.4 06/29/2005 18:40:00 6.9 0.6 8.4 4.9 6.8 0.7 8.4 4.6 211 6 221 305 6.5 0 6.9 6.4 06/29/2005 18:50:00 6.7 0.5 8 5.3 6.6 0.6 8 4.6 214 7 221 305 6.5 0 7.2 6.4 06/29/2005 19:00:00 6.4 0.7 8 4.6 6.2 0.7 7.6 4.2 217 7 222 305 6.5 0 6.7 6.1 06/29/2005 19:10:00 6.5 0.6 8 4.6 6.4 0.7 7.6 4.6 221 8 220 305 6.5 0 6.9 6.4 06/29/2005 19:20:00 6.4 0.7 8 4.6 6.3 0.7 8 4.6 221 5 221 305 6.5 0 6.7 6.1 06/29/2005 19:30:00 6.9 0.6 8.4 4.9 6.8 0.7 8.4 4.6 222 5 227 305 6.5 0 6.9 6.4 06/29/2005 19:40:00 6.9 0.4 8 5.3 6.6 0.5 8 4.9 216 7 215 305 6.4 0 6.7 6.1 06/29/2005 19:50:00 6.7 0.6 8 4.9 6.5 0.7 8 4.6 217 6 223 305 6.5 0 6.7 6.4 06/29/2005 20:00:00 6.9 0.6 8.4 4.9 6.7 0.7 8.4 4.6 216 5 214 305 6.3 0 6.4 6.1 06/29/2005 20:10:00 6.8 0.7 8.4 4.9 6.4 0.7 8 4.9 218 8 210 305 6.3 0 6.4 6.1 06/29/2005 20:20:00 6.6 0.5 8 4.9 6.4 0.4 8 5.3 231 6 237 305 6.2 0 6.4 6.1 06/29/2005 20:30:00 6.2 0.6 7.6 4.6 6 0.6 7.2 4.6 233 5 232 305 6.3 0 6.4 6.1 06/29/2005 20:40:00 6.2 0.7 7.6 3.8 5.9 0.7 7.6 3.8 230 5 245 305 6.1 0.1 6.4 5.9 06/29/2005 20:50:00 5.8 0.7 8.4 3.8 5.6 0.7 8.4 3.8 233 7 237 305 6.2 0 6.4 5.9 06/29/2005 21:00:00 5.4 0.7 6.8 3.4 5.2 0.7 6.8 3.8 229 9 228 305 6.2 0 6.4 5.9 06/29/2005 21:10:00 6.1 0.7 8 4.2 5.7 0.7 7.6 3.8 242 7 244 305 6.1 0 6.4 5.9 06/29/2005 21:20:00 6.6 0.7 8.4 4.6 6.2 0.8 8.4 4.2 235 6 234 305 6.1 0 6.1 5.9 06/29/2005 21:30:00 6.6 0.6 8 4.6 6.2 0.7 8 3.8 236 6 235 305 6 0 6.1 5.9 06/29/2005 21:40:00 5.7 0.6 7.2 4.2 5.4 0.6 6.8 3.8 237 6 237 305 6.2 0 6.4 5.9 06/29/2005 21:50:00 5.8 0.7 7.6 3.8 5.5 0.8 7.2 3.8 233 6 224 305 6.1 0 6.4 5.9 06/29/2005 22:00:00 6.1 0.6 7.2 4.9 5.9 0.6 7.6 4.6 222 6 218 305 6.2 0 6.4 6.1 06/29/2005 22:10:00 6.3 0.6 7.6 4.6 6.1 0.7 7.6 4.2 226 6 221 305 6.3 0 6.4 6.1 06/29/2005 22:20:00 6.6 0.7 8.4 4.9 6.4 0.7 8.8 4.6 225 6 218 305 6.5 0 6.7 6.1 06/29/2005 22:30:00 6.8 0.7 8.4 4.9 6.5 0.8 8.4 4.6 230 5 228 305 6.4 0 6.4 6.1 06/29/2005 22:40:00 6.9 0.7 8.8 4.9 6.6 0.8 8.4 4.6 223 6 218 305 6.5 0 6.7 6.4 06/29/2005 22:50:00 6.5 0.6 8 4.6 6.2 0.6 7.6 4.6 230 5 227 305 6.5 0 6.7 6.4 06/29/2005 23:00:00 6.8 0.7 8.4 4.2 6.5 0.8 8 4.9 227 5 232 305 6.5 0 6.7 6.1 06/29/2005 23:10:00 6.7 0.6 8 4.9 6.4 0.6 8 4.9 227 6 252 305 6.6 0 6.9 6.4 06/29/2005 23:20:00 6.8 0.6 8.4 4.6 6.6 0.7 8 4.6 227 5 234 305 6.6 0 6.9 6.4 06/29/2005 23:30:00 7.2 0.7 8.8 5.3 6.9 0.8 8.4 5.3 232 7 229 305 6.5 0 6.7 6.1 06/29/2005 23:40:00 8 0.8 9.5 5.7 7.7 0.8 9.5 5.7 227 5 222 305 6.5 0 6.7 6.1 06/29/2005 23:50:00 8 0.7 9.9 6.1 7.6 0.9 9.9 5.3 234 5 237 305 6.3 0 6.7 6.1 06/30/2005 00:00:00 7.8 0.6 9.1 5.7 7.3 0.7 9.1 5.7 231 6 234 305 6.3 0 6.7 6.1 06/30/2005 00:10:00 8.4 0.9 10.3 6.1 7.8 1 9.5 5.7 238 5 242 305 6.1 0 6.4 5.9 06/30/2005 00:20:00 8.3 0.6 9.5 6.1 7.9 0.7 9.5 5.7 230 5 224 305 6.1 0 6.4 5.9 06/30/2005 00:30:00 8.1 0.7 9.5 5.7 7.3 0.8 9.5 4.9 235 5 238 305 6.3 0 6.4 5.9 06/30/2005 00:40:00 8.9 0.7 10.3 6.1 8.2 0.8 9.9 5.7 241 5 240 305 6.3 0 6.4 6.1 06/30/2005 00:50:00 8.3 0.8 9.9 5.7 7.7 0.9 9.5 4.9 239 5 240 305 6.3 0 6.4 6.1 06/30/2005 01:00:00 8.8 0.6 10.3 6.5 8.2 0.8 9.9 6.1 235 5 232 305 6.4 0 6.4 6.1 06/30/2005 01:10:00 8.8 0.9 10.7 5.7 8.2 0.9 9.9 4.9 236 5 226 305 6.3 0 6.4 6.1 06/30/2005 01:20:00 8.5 1.2 10.7 4.9 7.8 1.2 10.3 4.9 237 5 237 305 6.4 0 6.4 6.1 06/30/2005 01:30:00 7.2 0.9 9.5 5.3 6.7 0.8 8.8 4.6 235 6 229 305 6.4 0 6.4 6.1 06/30/2005 01:40:00 8 0.9 10.7 5.3 7.2 0.8 9.5 4.9 237 5 234 305 6.5 0 6.7 6.4 06/30/2005 01:50:00 7.9 0.7 9.1 6.1 7.2 0.8 9.1 4.9 241 7 242 305 6.5 0 6.7 6.1 06/30/2005 02:00:00 8 0.7 9.5 5.7 7.5 0.7 9.1 5.3 238 5 242 305 6.5 0 6.4 6.1 06/30/2005 02:10:00 7.6 0.9 9.9 5.7 7.2 0.9 9.9 5.3 238 6 239 305 6.4 0 6.4 6.1 06/30/2005 02:20:00 7.7 0.6 9.5 6.1 7.2 0.8 8.8 5.3 237 5 237 305 6.5 0 6.7 6.4 06/30/2005 02:30:00 7.6 0.8 9.1 5.3 7 0.7 8.8 5.3 236 6 246 305 6.5 0 6.7 6.4 06/30/2005 02:40:00 7.1 0.7 8.8 5.7 6.6 0.8 8.4 4.6 235 6 244 305 6.6 0 6.9 6.4 06/30/2005 02:50:00 7.5 1 9.9 5.3 7.1 1 9.1 4.9 236 6 243 305 6.7 0 6.9 6.4 06/30/2005 03:00:00 7.4 1 9.5 4.9 6.7 1 9.1 4.6 236 6 233 305 6.7 0 6.9 6.4 06/30/2005 03:10:00 7.7 0.8 9.5 5.3 7.1 0.9 8.8 4.6 238 5 246 305 6.7 0 6.9 6.4 06/30/2005 03:20:00 7.7 0.8 9.9 5.7 6.9 0.8 9.1 4.6 242 7 248 305 6.7 0 6.9 6.4 06/30/2005 03:30:00 8.2 0.9 10.3 5.7 7.6 0.9 9.5 5.7 238 6 241 305 6.7 0 6.9 6.4 06/30/2005 03:40:00 8.5 1 10.3 5.7 7.7 1 9.9 4.9 241 6 239 305 6.7 0 6.9 6.4 06/30/2005 03:50:00 7.8 0.8 9.5 5.7 7.2 0.9 9.1 4.9 247 5 245 305 6.5 0 6.7 6.4 06/30/2005 04:00:00 9 0.8 10.3 6.5 8.3 1 10.3 5.3 245 5 244 305 6.5 0 6.7 6.4 06/30/2005 04:10:00 8.7 0.7 10.3 6.5 7.9 0.9 9.9 5.3 245 5 242 305 6.5 0 6.7 6.4 06/30/2005 04:20:00 8 1 9.9 5.7 7.2 1 9.9 4.6 241 7 245 305 6.6 0 6.9 6.4 06/30/2005 04:30:00 7.7 0.7 9.9 5.3 7.1 0.9 9.5 4.2 246 5 252 305 6.6 0 6.9 6.4 06/30/2005 04:40:00 6.5 0.6 8 4.9 5.9 0.7 7.6 4.2 242 6 239 305 6.6 0 6.9 6.4 06/30/2005 04:50:00 6.5 0.6 8 4.9 5.8 0.7 7.2 4.2 238 5 238 305 6.7 0 6.9 6.7 06/30/2005 05:00:00 7.6 0.9 9.9 5.7 6.9 1 9.5 4.9 242 6 247 305 6.7 0 6.9 6.7 06/30/2005 05:10:00 7.7 0.7 9.9 5.7 7.1 0.8 9.1 4.9 237 6 238 305 6.7 0 6.9 6.4 06/30/2005 05:20:00 7.8 0.7 9.5 6.1 7.3 0.7 9.1 5.3 232 5 234 305 6.7 0 6.9 6.4 06/30/2005 05:30:00 8.1 0.6 9.5 6.1 7.7 0.7 9.5 6.1 231 4 227 305 6.7 0 6.9 6.7 06/30/2005 05:40:00 8.3 0.8 9.9 6.1 7.7 0.8 9.1 5.3 234 5 234 305 6.7 0 6.9 6.7 06/30/2005 05:50:00 8.1 0.9 9.9 5.7 7.5 1 9.9 5.3 237 6 236 305 6.7 0 6.9 6.4 06/30/2005 06:00:00 7.4 0.6 9.1 5.3 7 0.6 8.4 4.9 232 5 232 305 6.6 0 6.9 6.4 06/30/2005 06:10:00 8.1 0.8 9.9 5.3 7.7 0.8 9.9 6.1 231 5 239 305 6.5 0 6.7 6.4 06/30/2005 06:20:00 7.8 0.7 9.5 5.7 7.5 0.7 9.5 5.7 229 5 235 305 6.5 0 6.7 6.4 06/30/2005 06:30:00 8 0.7 9.5 6.1 7.4 0.7 9.1 5.3 233 5 232 305 6.5 0 6.7 6.4 06/30/2005 06:40:00 7.8 0.7 9.9 6.1 7.3 0.7 9.5 5.3 233 5 239 305 6.6 0 6.9 6.4 06/30/2005 06:50:00 7.2 0.7 8.8 5.3 6.8 0.7 8.4 4.9 233 6 239 305 6.6 0 6.9 6.4 06/30/2005 07:00:00 7.6 0.6 9.1 5.7 7.3 0.6 8.8 5.7 228 5 228 305 6.6 0 6.7 6.4 06/30/2005 07:10:00 7.3 0.7 9.1 5.3 6.9 0.8 8.8 4.9 226 5 228 305 6.6 0 6.9 6.4 06/30/2005 07:20:00 7 0.6 8.8 5.3 6.6 0.6 8 4.9 226 5 235 305 6.7 0 6.9 6.4 06/30/2005 07:30:00 7.4 0.6 8.8 5.3 7 0.7 8.4 4.6 226 5 224 305 6.7 0 6.9 6.4 06/30/2005 07:40:00 8 0.8 9.9 6.1 7.4 0.8 9.9 4.9 231 7 227 305 6.7 0 6.9 6.4 06/30/2005 07:50:00 8.3 0.8 9.9 6.1 7.7 0.9 9.5 5.3 238 5 234 305 6.7 0 6.9 6.4 06/30/2005 08:00:00 8.4 1 10.7 6.1 7.8 1 10.3 5.3 237 5 240 305 6.7 0 6.9 6.4 06/30/2005 08:10:00 8.4 0.7 9.9 6.5 8 0.8 9.9 5.7 231 5 229 305 6.7 0 6.9 6.4 06/30/2005 08:20:00 8.4 0.7 9.9 6.1 7.9 0.8 9.5 6.1 233 6 229 305 6.7 0 6.9 6.4 06/30/2005 08:30:00 8.3 0.8 9.9 6.5 7.8 0.9 9.9 5.7 238 5 245 305 6.7 0 6.9 6.7 06/30/2005 08:40:00 8.6 0.8 10.7 5.7 7.9 1 9.9 4.9 243 5 238 305 6.7 0 6.9 6.4 06/30/2005 08:50:00 7.9 0.8 9.5 5.7 7.3 0.9 9.5 4.9 248 6 250 305 6.5 0 6.7 6.4 06/30/2005 09:00:00 8.5 1.1 10.7 5.7 7.8 1.3 10.3 4.2 246 7 245 305 6.3 0 6.4 6.1 06/30/2005 09:10:00 9 1 11.1 6.1 8.3 1 11.1 5.7 243 5 242 305 6.1 0 6.4 6.1 06/30/2005 09:20:00 8 0.9 9.9 5.3 7.4 1 10.3 4.9 245 7 245 305 6.3 0 6.4 6.1 06/30/2005 09:30:00 8.1 0.9 9.9 5.7 7.4 1.1 9.9 4.2 242 6 248 305 6.4 0 6.7 6.1 06/30/2005 09:40:00 7.4 0.8 9.5 4.9 6.7 0.9 8.8 4.6 239 6 242 305 6.6 0 6.9 6.4 06/30/2005 09:50:00 7.3 0.8 9.1 5.3 6.8 0.9 8.8 4.6 241 6 247 305 6.8 0 7.2 6.7 06/30/2005 10:00:00 7.4 0.9 9.1 4.9 6.7 1 8.8 4.6 244 7 238 305 6.8 0 6.9 6.7 06/30/2005 10:10:00 7.1 1 9.1 4.6 6.4 1 8.8 3.8 244 7 242 305 6.8 0 6.9 6.7 06/30/2005 10:20:00 7 0.9 8.8 4.6 6.3 0.9 8.4 4.2 245 6 246 305 6.8 0 6.9 6.7 06/30/2005 10:30:00 7.4 1 9.5 4.9 6.6 1.2 9.9 3.4 250 8 248 305 6.8 0 7.2 6.7 06/30/2005 10:40:00 6.5 1 8.8 4.6 5.9 1.1 8.8 3.4 249 8 251 305 6.9 0 7.2 6.7 06/30/2005 10:50:00 7 0.8 9.5 5.3 6.3 1 8.8 3.4 252 8 252 305 7 0 7.2 6.9 06/30/2005 11:00:00 7.7 1 9.5 4.6 6.9 1.2 9.9 3.4 254 7 255 305 7 0 7.2 6.9 06/30/2005 11:10:00 5.7 0.6 7.6 4.2 5 0.7 6.8 3.4 252 7 251 305 7 0 7.2 6.9 06/30/2005 11:20:00 6.9 1 9.1 4.6 6 1.1 8.8 3.8 255 7 252 305 7 0 7.2 6.9 06/30/2005 11:30:00 5.6 0.8 7.6 3.8 4.8 0.9 7.2 2.6 251 11 254 305 7.2 0 7.4 7.2 06/30/2005 11:40:00 6 1 8.4 3.4 5.7 1 7.6 3.4 238 8 243 305 7.3 0 7.4 7.2 06/30/2005 11:50:00 6.4 0.7 7.6 4.6 6.1 0.6 8 4.6 237 6 234 305 7.5 0 7.7 7.2 06/30/2005 12:00:00 6.2 0.6 7.6 4.6 5.9 0.6 7.6 4.6 237 6 244 305 7.5 0 7.7 7.4 06/30/2005 12:10:00 5.6 0.7 7.2 3.8 5.5 0.6 6.8 3.8 238 7 234 305 7.5 0 7.7 7.4 06/30/2005 12:20:00 5.9 0.7 7.2 3.8 5.7 0.7 7.2 4.2 242 7 251 305 7.5 0 7.7 7.4 06/30/2005 12:30:00 4.8 0.7 6.8 3 4.8 0.7 7.2 3 236 9 242 305 7.5 0 7.7 7.4 06/30/2005 12:40:00 5.8 0.8 7.6 3.4 5.6 0.8 7.6 3.8 237 6 231 305 7.5 0 7.7 7.4 06/30/2005 12:50:00 5.5 0.7 7.2 3.8 5 0.7 6.5 3.4 234 7 238 305 7.6 0 7.9 7.4 06/30/2005 13:00:00 5.6 0.6 7.2 4.2 5.3 0.6 6.8 3.8 244 9 245 305 7.7 0 7.9 7.4 06/30/2005 13:10:00 5.9 0.8 8 3.8 5.6 0.8 7.2 3.4 250 9 255 305 7.7 0 7.9 7.7 06/30/2005 13:20:00 6.1 0.7 7.6 3.8 5.8 0.8 7.6 3.8 248 8 250 305 7.8 0 7.9 7.7 06/30/2005 13:30:00 5.2 0.6 6.8 3.4 5.1 0.6 6.8 3 245 8 254 305 7.9 0 8.2 7.7 06/30/2005 13:40:00 5.4 0.6 6.8 3.8 5.2 0.6 6.8 3.8 239 8 244 305 8 0 8.4 7.7 06/30/2005 13:50:00 5.5 0.7 7.2 3.8 5.4 0.7 7.2 3.8 239 7 238 305 7.7 0 8.2 7.7 06/30/2005 14:00:00 5.6 0.8 7.2 3.4 5.4 0.8 7.2 3.8 240 7 253 305 7.9 0 8.4 7.7 06/30/2005 14:10:00 5.8 0.6 7.6 4.2 5.7 0.6 7.2 3.8 240 7 238 305 7.9 0 8.4 7.7 06/30/2005 14:20:00 5.1 0.6 6.8 3.8 5 0.6 6.5 3.8 239 7 231 305 7.9 0 8.4 7.7 06/30/2005 14:30:00 4.9 0.7 6.5 3.4 4.8 0.7 6.5 3.4 242 8 246 305 7.9 0 8.4 7.7 06/30/2005 14:40:00 5.4 0.7 7.2 3.8 5.3 0.7 7.2 3 246 7 241 305 7.6 0 8.2 7.7 06/30/2005 14:50:00 5.2 0.6 6.5 3 5.1 0.6 6.5 3 248 7 246 305 7.6 0 7.7 7.4 06/30/2005 15:00:00 4.7 0.7 6.5 2.3 4.5 0.7 6.1 3 247 9 244 305 7.7 0 7.9 7.4 06/30/2005 15:10:00 4.9 0.7 6.1 3 4.8 0.7 6.5 3 249 8 248 305 7.9 0.1 8.2 7.7 06/30/2005 15:20:00 4.7 0.7 6.1 2.6 4.6 0.6 6.5 2.3 246 10 251 305 7.9 0 8.2 7.7 06/30/2005 15:30:00 5.3 0.7 6.8 3.8 5.2 0.6 6.8 3.4 242 8 247 305 7.9 0 8.4 7.7 06/30/2005 15:40:00 4.4 0.6 6.1 2.6 4.3 0.5 6.1 3 245 9 225 305 7.9 0 8.4 7.7 06/30/2005 15:50:00 4.5 0.7 6.5 3 4.4 0.7 6.1 2.6 247 10 236 305 7.8 0 8.4 7.7 06/30/2005 16:00:00 4.1 0.7 6.1 2.3 3.9 0.7 6.1 2.3 256 11 258 305 7.9 0 8.4 7.7 06/30/2005 16:10:00 5.3 0.7 6.5 3 4.7 0.8 6.5 2.3 264 8 266 305 7.8 0.1 8.4 7.7 06/30/2005 16:20:00 4.8 0.7 6.5 3 4.5 0.8 6.1 2.6 263 9 262 305 7.8 0 8.4 7.7 06/30/2005 16:30:00 4.9 0.7 6.5 3 4.2 0.6 6.1 2.3 266 9 262 305 7.8 0.1 8.4 7.7 06/30/2005 16:40:00 4.1 0.6 5.7 2.6 3.5 0.6 5.3 1.9 270 11 263 305 7.9 0 8.4 7.9 06/30/2005 16:50:00 4.3 0.6 6.1 3 3.8 0.6 5.3 2.3 275 8 275 305 7.6 0 8.2 7.7 06/30/2005 17:00:00 3.8 0.5 5.3 2.3 3.6 0.5 4.9 2.3 279 9 264 305 7.7 0 7.9 7.4 06/30/2005 17:10:00 4 0.5 5.3 3 3.9 0.6 6.1 2.3 283 9 304 305 7.9 0 7.9 7.7 06/30/2005 17:20:00 3.7 0.4 4.6 2.6 3.5 0.5 4.6 2.3 282 9 282 305 7.9 0 7.9 7.7 06/30/2005 17:30:00 4 0.5 4.9 2.6 3.6 0.5 4.9 2.3 279 8 275 305 7.7 0 7.9 7.7 06/30/2005 17:40:00 3.7 0.5 4.9 2.6 3.5 0.5 4.9 2.3 280 7 286 305 7.6 0 7.9 7.4 06/30/2005 17:50:00 3 0.5 4.6 1.5 2.8 0.5 4.2 1.1 273 11 290 305 7.6 0 7.7 7.7 06/30/2005 18:00:00 3 0.5 4.2 1.9 3 0.5 4.2 1.9 285 11 289 305 7.7 0 7.9 7.7 06/30/2005 18:10:00 2.5 0.5 3.8 0.7 2.6 0.4 3.4 1.5 271 12 288 305 7.5 0 7.9 7.4 06/30/2005 18:20:00 2.5 0.4 3.4 1.1 2.5 0.5 3.8 1.1 259 9 251 305 7.3 0 7.4 7.2 06/30/2005 18:30:00 2.5 0.6 3.8 0.4 2.5 0.6 3.8 0.7 257 11 242 305 7.3 0 7.7 7.2 06/30/2005 18:40:00 2.5 0.5 4.2 0.7 2.5 0.6 3.8 1.1 263 11 246 305 7.2 0 7.7 7.2 06/30/2005 18:50:00 2.4 0.4 3.4 1.5 2.2 0.4 3.4 1.1 263 11 262 305 7.2 0 7.7 7.2 06/30/2005 19:00:00 2.1 0.5 3.4 0.4 2.1 0.5 3.4 0.7 267 12 276 305 7.2 0 7.4 7.2 06/30/2005 19:10:00 2.5 0.5 3.8 1.1 2.6 0.5 3.8 1.1 283 9 283 305 7.2 0 7.4 7.2 06/30/2005 19:20:00 2.2 0.6 3.4 0.4 2.3 0.5 3.4 0.7 289 13 298 305 7.4 0 7.7 7.2 06/30/2005 19:30:00 2.4 0.4 3.4 1.1 2.7 0.3 3.8 1.9 302 11 298 305 7.3 0.1 7.7 7.2 06/30/2005 19:40:00 2.4 0.4 3.4 1.5 2.7 0.4 3.4 1.9 309 6 302 305 7.2 0 7.4 7.2 06/30/2005 19:50:00 2.3 0.4 3.4 1.5 2.6 0.3 3.4 1.9 309 6 311 305 7.1 0 7.4 6.9 06/30/2005 20:00:00 2.4 0.4 3.4 1.5 2.7 0.4 3.8 1.9 304 9 308 305 7 0 7.2 6.9 06/30/2005 20:10:00 2.2 0.4 3 1.1 2.1 0.4 3 1.1 282 9 282 305 7 0 7.2 6.9 06/30/2005 20:20:00 2.1 0.4 3 1.1 2.2 0.4 3.4 1.1 281 9 285 305 7 0 7.2 6.9 06/30/2005 20:30:00 1.9 0.4 2.6 0.7 2.1 0.4 3 1.1 280 8 285 305 7 0 7.2 6.9 06/30/2005 20:40:00 1.6 0.5 2.6 0.4 1.8 0.4 2.6 0.7 282 9 279 305 7 0 7.2 6.9 06/30/2005 20:50:00 1.7 0.5 2.6 0.4 1.9 0.4 3 1.1 280 10 277 305 7 0 7.2 6.9 06/30/2005 21:00:00 1.2 0.6 3 0.4 1.6 0.4 3 0.7 277 11 280 305 7 0 7.2 6.9 06/30/2005 21:10:00 1.7 0.4 3 0.7 1.8 0.4 2.6 0.7 276 9 275 305 7.1 0 7.2 7.2 06/30/2005 21:20:00 1.4 0.6 2.6 0.4 1.6 0.5 2.6 0.7 271 15 271 305 7.1 0 7.4 7.2 06/30/2005 21:30:00 1.6 0.5 2.6 0.4 1.7 0.4 2.6 0.7 277 13 275 305 7.1 0 7.4 7.2 06/30/2005 21:40:00 1.9 0.4 3 1.1 2.1 0.4 3.4 1.1 288 8 290 305 7.1 0 7.2 7.2 06/30/2005 21:50:00 1.7 0.5 3 0.4 2.1 0.3 3 1.1 299 8 304 305 7.1 0 7.2 7.2 06/30/2005 22:00:00 1.6 0.5 2.6 0.4 2 0.4 3 1.1 292 9 284 305 7.1 0 7.4 7.2 06/30/2005 22:10:00 1.5 0.5 2.6 0.4 1.9 0.4 2.6 1.1 289 14 300 305 7.1 0 7.2 7.2 06/30/2005 22:20:00 1.2 0.7 2.3 0.4 1.6 0.5 2.6 0.7 279 15 272 305 7 0 7.2 7.2 06/30/2005 22:30:00 0.9 0.6 2.3 0.4 1.2 0.5 2.3 0.4 278 13 284 305 7 0 7.2 7.2 06/30/2005 22:40:00 1.2 0.6 2.6 0.4 1.5 0.5 2.6 0.4 289 9 283 305 7 0 7.2 6.9 06/30/2005 22:50:00 1.3 0.6 3 0.4 1.4 0.5 2.6 0.4 275 15 273 305 7 0 7.2 6.9 06/30/2005 23:00:00 1.1 0.5 2.3 0.4 1.4 0.5 2.6 0.4 264 22 277 305 7 0 7.2 6.9 06/30/2005 23:10:00 0.6 0.4 1.9 0.4 1.1 0.4 1.9 0.4 247 20 247 305 7 0 7.2 6.9 06/30/2005 23:20:00 0.8 0.5 2.3 0.4 1 0.5 2.3 0.4 259 20 281 305 6.9 0 7.2 6.9 06/30/2005 23:30:00 0.8 0.5 2.3 0.4 1.1 0.5 2.3 0.4 273 22 278 305 6.8 0 6.9 6.7 06/30/2005 23:40:00 0.4 0.1 1.5 0.4 0.4 0.2 1.1 0.4 304 23 289 305 6.8 0 6.9 6.7 06/30/2005 23:50:00 0.6 0.4 2.3 0.4 0.8 0.5 2.3 0.4 286 22 294 305 6.7 0 6.9 6.7 07/01/2005 00:00:00 0.8 0.5 2.3 0.4 1.1 0.5 2.3 0.4 306 12 314 305 6.7 0 6.9 6.7 07/01/2005 00:10:00 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 305 17 305 305 6.7 0 6.9 6.7 07/01/2005 00:20:00 0.6 0.5 2.6 0.4 0.7 0.6 2.6 0.4 306 79 329 305 6.7 0 6.9 6.4 07/01/2005 00:30:00 1.2 0.6 2.6 0.4 1.7 0.5 2.6 0.4 356 18 343 305 6.5 0 6.9 6.4 07/01/2005 00:40:00 1.4 0.6 3 0.4 1.7 0.5 3 0.7 12 20 5 305 6.5 0 6.7 6.4 07/01/2005 00:50:00 0.9 0.5 2.3 0.4 1.5 0.5 2.6 0.4 16 27 28 305 6.5 0 6.4 6.4 07/01/2005 01:00:00 0.8 0.6 2.6 0.4 1.3 0.6 3 0.4 22 43 9 305 6.5 0 6.7 6.1 07/01/2005 01:10:00 0.9 0.6 2.6 0.4 1.7 0.4 3 0.7 16 17 359 305 6.5 0 6.7 6.4 07/01/2005 01:20:00 0.5 0.4 2.3 0.4 1.1 0.5 2.3 0.4 9 15 18 305 6.5 0 6.7 6.4 07/01/2005 01:30:00 0.8 0.5 2.3 0.4 1.4 0.5 3 0.4 7 12 7 305 6.5 0 6.7 6.1 07/01/2005 01:40:00 1.2 0.6 3 0.4 1.7 0.5 3 0.7 0 14 341 305 6.4 0 6.4 6.1 07/01/2005 01:50:00 0.5 0.3 1.9 0.4 1 0.5 2.3 0.4 7 22 11 305 6.4 0 6.4 6.1 07/01/2005 02:00:00 0.6 0.4 2.6 0.4 0.9 0.5 2.6 0.4 340 27 7 305 6.4 0 6.4 6.1 07/01/2005 02:10:00 0.4 0.2 1.9 0.4 0.6 0.4 2.6 0.4 40 22 10 305 6.4 0 6.4 6.1 07/01/2005 02:20:00 0.6 0.4 1.9 0.4 1.1 0.4 2.3 0.4 24 17 40 305 6.4 0 6.4 6.1 07/01/2005 02:30:00 0.6 0.3 1.9 0.4 1.3 0.4 2.3 0.4 44 23 32 305 6.4 0 6.4 6.1 07/01/2005 02:40:00 0.6 0.3 1.5 0.4 1.3 0.4 2.3 0.4 24 19 28 305 6.3 0 6.4 6.1 07/01/2005 02:50:00 0.4 0.2 1.5 0.4 0.8 0.4 1.9 0.4 29 15 11 305 6.4 0 6.4 6.1 07/01/2005 03:00:00 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 6 16 22 305 6.3 0 6.4 6.1 07/01/2005 03:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 34 23 305 305 6.2 0 6.4 6.1 07/01/2005 03:20:00 0.4 0.2 1.9 0.4 0.5 0.3 1.9 0.4 15 26 358 305 6.1 0 6.4 5.9 07/01/2005 03:30:00 0.4 0.2 1.5 0.4 1 0.5 2.3 0.4 8 22 10 305 6.3 0 6.4 6.1 07/01/2005 03:40:00 0.5 0.3 1.9 0.4 0.9 0.4 1.9 0.4 5 11 7 305 6.2 0 6.4 5.9 07/01/2005 03:50:00 0.5 0.3 1.9 0.4 1.1 0.5 2.3 0.4 10 23 31 305 6.2 0 6.4 6.1 07/01/2005 04:00:00 0.5 0.3 1.5 0.4 0.9 0.4 2.3 0.4 22 32 32 305 6.2 0 6.4 5.9 07/01/2005 04:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 357 22 305 305 6.2 0 6.4 5.9 07/01/2005 04:20:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 10 10 305 305 6.2 0 6.4 6.1 07/01/2005 04:30:00 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 16 12 36 305 6.2 0 6.4 6.1 07/01/2005 04:40:00 0.4 0.1 1.1 0.4 0.6 0.4 2.3 0.4 21 12 16 305 6.3 0 6.4 6.1 07/01/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 17 2 305 305 6.1 0.1 6.4 5.9 07/01/2005 05:00:00 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 24 9 305 305 6 0.1 6.4 5.9 07/01/2005 05:10:00 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 43 30 305 305 6.1 0.1 6.4 5.9 07/01/2005 05:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 71 22 305 305 6 0 6.4 5.9 07/01/2005 05:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 32 12 305 305 6 0 6.4 5.9 07/01/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 1 305 305 6.5 0.2 7.2 6.1 07/01/2005 05:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 66 1 305 305 7.3 0.2 7.7 6.9 07/01/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 352 30 305 305 7.4 0.2 7.9 7.2 07/01/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 313 1 305 305 6.8 0 7.2 6.7 07/01/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 312 1 305 305 6.7 0 6.9 6.4 07/01/2005 06:30:00 0.4 0 0.4 0.4 0.8 0.4 1.5 0.4 306 8 305 305 6.6 0 6.9 6.4 07/01/2005 06:40:00 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 311 16 305 305 6.6 0 6.7 6.4 07/01/2005 06:50:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 305 1 305 305 6.6 0 6.9 6.4 07/01/2005 07:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 305 0 305 305 6.7 0 6.9 6.4 07/01/2005 07:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 305 1 305 305 6.7 0 6.9 6.7 07/01/2005 07:20:00 0.4 0 0.4 0.4 0.8 0.2 1.5 0.4 305 1 305 305 6.8 0 6.9 6.7 07/01/2005 07:30:00 0.4 0.1 1.1 0.4 1.3 0.2 1.9 0.7 320 15 347 305 6.7 0 6.9 6.7 07/01/2005 07:40:00 0.8 0.3 1.1 0.4 1.5 0.2 2.3 0.7 359 5 347 305 6.7 0 6.9 6.4 07/01/2005 07:50:00 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 3 2 305 305 6.7 0 6.9 6.4 07/01/2005 08:00:00 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 12 8 305 305 6.8 0 7.2 6.7 07/01/2005 08:10:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 14 2 305 305 7 0 7.4 6.9 07/01/2005 08:20:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 4 9 305 305 7.3 0 7.7 7.2 07/01/2005 08:30:00 0.4 0.1 1.1 0.4 1 0.5 2.3 0.4 339 10 348 305 7.5 0 7.7 7.4 07/01/2005 08:40:00 0.4 0.1 1.1 0.4 1.1 0.3 1.9 0.4 352 3 351 305 7.5 0 7.7 7.4 07/01/2005 08:50:00 0.4 0.2 1.5 0.4 1.2 0.3 1.9 0.4 4 8 351 305 7.5 0 7.7 7.4 07/01/2005 09:00:00 0.6 0.4 1.5 0.4 1.5 0.4 2.3 0.7 339 7 331 305 7.6 0 7.7 7.7 07/01/2005 09:10:00 0.5 0.3 1.5 0.4 1.3 0.4 2.3 0.4 347 15 357 305 7.6 0 7.7 7.7 07/01/2005 09:20:00 0.8 0.4 2.3 0.4 1.6 0.3 2.3 1.1 331 9 331 305 7.6 0 7.7 7.7 07/01/2005 09:30:00 0.5 0.3 1.5 0.4 1.4 0.4 2.3 0.4 317 7 321 305 7.9 0 8.2 7.7 07/01/2005 09:40:00 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 266 43 298 305 8.6 0.2 9.5 8.2 07/01/2005 09:50:00 1.1 0.5 2.3 0.4 1.8 0.4 3 0.7 316 13 330 305 9 0 9.5 8.9 07/01/2005 10:00:00 1.5 0.5 2.6 0.4 2.1 0.4 3.4 0.7 324 17 316 305 8.9 0.1 9.2 8.9 07/01/2005 10:10:00 1.3 0.6 3 0.4 1.8 0.5 3.4 0.7 318 15 303 305 8.9 0.1 9.5 8.9 07/01/2005 10:20:00 1 0.5 2.3 0.4 1.6 0.5 2.6 0.4 312 27 310 305 9.2 0 9.7 8.9 07/01/2005 10:30:00 1.3 0.6 2.6 0.4 1.9 0.5 3 0.7 306 14 315 305 9.3 0.1 10 9.2 07/01/2005 10:40:00 1.9 0.7 3.8 0.4 1.9 0.6 3 0.7 274 13 244 305 9.4 0.1 10 9.2 07/01/2005 10:50:00 1.9 0.7 3.4 0.4 2 0.5 3.4 0.7 269 14 258 305 9.5 0.2 10 9.2 07/01/2005 11:00:00 1.6 0.8 3.8 0.4 1.9 0.5 3.8 0.7 282 21 279 305 9.4 0.2 10 9.2 07/01/2005 11:10:00 1.6 0.8 3 0.4 1.8 0.6 3.4 0.4 289 17 302 305 9.4 0.1 10 8.9 07/01/2005 11:20:00 1.3 0.6 2.6 0.4 1.5 0.6 2.6 0.4 284 19 291 305 9.1 0.2 10 8.9 07/01/2005 11:30:00 1.6 0.7 3 0.4 1.8 0.6 3.4 0.7 284 20 287 305 9.7 0.1 10.2 9.5 07/01/2005 11:40:00 1.6 0.7 3.8 0.4 1.9 0.7 3.8 0.4 306 24 315 305 9.7 0.2 10.2 9.2 07/01/2005 11:50:00 0.8 0.6 2.6 0.4 1.2 0.6 3 0.4 312 22 330 305 9.2 0.1 9.5 8.9 07/01/2005 12:00:00 0.9 0.5 2.3 0.4 1.2 0.5 2.3 0.4 310 29 287 305 10 0.2 10.5 9.5 07/01/2005 12:10:00 1 0.6 2.6 0.4 1.4 0.6 3 0.4 306 27 323 305 10.6 0.1 10.8 10.2 07/01/2005 12:20:00 1.2 0.7 3.4 0.4 1.7 0.6 3.4 0.4 308 27 312 305 10.7 0.1 11.3 10.5 07/01/2005 12:30:00 1.1 0.7 3.4 0.4 1.5 0.5 3 0.4 283 26 300 305 11.3 0 11.6 11 07/01/2005 12:40:00 1.6 0.6 3 0.4 1.9 0.6 3.8 0.7 278 20 278 305 11 0.1 11.3 10.8 07/01/2005 12:50:00 1.7 0.8 4.2 0.4 1.9 0.7 3.8 0.4 245 27 227 305 10.6 0.1 11 10.2 07/01/2005 13:00:00 1.4 0.6 2.6 0.4 1.6 0.5 3 0.7 226 23 205 305 10.8 0 11 10.8 07/01/2005 13:10:00 1.5 0.6 3 0.4 2 0.5 3 1.1 211 18 205 305 10.9 0 11.3 10.8 07/01/2005 13:20:00 1.9 0.6 3.4 0.4 2.1 0.5 3 0.7 223 21 212 305 11 0 11 10.8 07/01/2005 13:30:00 1.9 0.6 3.4 0.4 2.3 0.5 3.4 1.1 220 19 193 305 11 0 11.3 10.8 07/01/2005 13:40:00 1.8 0.6 3 0.4 2 0.5 3 0.7 216 17 207 305 11.4 0 11.6 11.3 07/01/2005 13:50:00 2.3 0.6 3.8 1.1 2.4 0.5 3.8 1.1 240 28 213 305 11.3 0 11.6 11 07/01/2005 14:00:00 2.6 0.6 4.6 1.5 2.5 0.6 3.8 1.1 253 21 232 305 11.2 0 11.6 11 07/01/2005 14:10:00 3 0.6 4.2 0.7 3 0.7 4.6 0.4 223 13 212 305 10.6 0.3 11.3 10 07/01/2005 14:20:00 3.2 0.6 4.2 0.7 3.2 0.5 4.6 1.9 225 15 237 305 9.9 0 10.2 9.7 07/01/2005 14:30:00 3.4 0.6 4.9 1.5 3.3 0.6 4.6 0.7 228 14 232 305 10 0 10.2 10 07/01/2005 14:40:00 2.8 0.7 4.9 1.1 2.9 0.5 4.2 1.5 235 17 264 305 10.2 0.1 10.5 10 07/01/2005 14:50:00 2.7 0.6 4.6 1.1 2.6 0.6 4.2 1.1 256 17 257 305 10.4 0 10.8 10.2 07/01/2005 15:00:00 2.9 0.7 4.9 0.7 2.9 0.6 4.6 1.1 257 14 248 305 10.2 0 10.5 10 07/01/2005 15:10:00 3.3 0.5 5.3 2.3 3.1 0.5 4.9 1.9 255 11 247 305 10.1 0.1 10.5 10 07/01/2005 15:20:00 3.6 0.6 5.7 2.3 3.3 0.7 4.9 1.9 256 16 231 305 10 0 10.2 9.7 07/01/2005 15:30:00 3.7 0.5 5.3 2.3 3.5 0.6 5.3 2.3 253 13 258 305 9.4 0.2 10 8.9 07/01/2005 15:40:00 3.2 0.8 5.3 0.4 3.1 0.8 4.9 1.1 258 17 272 305 9 0 9.2 8.9 07/01/2005 15:50:00 3.5 0.5 5.3 1.9 3.5 0.6 4.9 1.9 246 13 242 305 8.6 0.2 9.2 8.2 07/01/2005 16:00:00 3.5 0.5 4.9 2.3 3.4 0.6 5.3 1.9 246 13 241 305 8.5 0.2 8.9 8.2 07/01/2005 16:10:00 3.6 0.6 4.9 1.9 3.6 0.7 5.7 2.3 240 13 241 305 8.2 0.1 8.4 7.9 07/01/2005 16:20:00 3.8 0.5 4.9 2.3 3.8 0.5 4.9 2.6 231 10 236 305 8 0.1 8.2 7.7 07/01/2005 16:30:00 4 0.5 5.7 2.6 3.9 0.5 5.7 2.6 239 9 238 305 7.9 0.2 8.2 7.7 07/01/2005 16:40:00 3.8 0.5 4.9 2.3 3.9 0.5 4.9 2.6 233 9 240 305 7.6 0 7.9 7.4 07/01/2005 16:50:00 3.8 0.5 4.9 2.6 3.9 0.6 5.3 2.6 235 11 231 305 7.5 0 7.7 7.4 07/01/2005 17:00:00 4 0.5 5.7 2.6 3.9 0.5 4.9 2.6 245 11 256 305 7.2 0.1 7.4 7.2 07/01/2005 17:10:00 3.8 0.5 4.9 2.3 3.7 0.5 4.9 1.9 237 12 221 305 7.2 0 7.4 7.2 07/01/2005 17:20:00 4 0.5 5.3 2.6 3.9 0.5 4.9 2.6 246 8 243 305 7.2 0 7.4 7.2 07/01/2005 17:30:00 3.8 0.7 5.3 2.3 3.7 0.7 4.9 1.5 246 10 246 305 7.2 0.1 7.4 7.2 07/01/2005 17:40:00 3.6 0.5 4.9 2.3 3.7 0.5 4.9 2.3 238 11 252 305 7.4 0 7.7 7.2 07/01/2005 17:50:00 3.9 0.7 5.7 2.6 3.7 0.6 5.3 2.3 239 16 253 305 7.3 0 7.7 7.2 07/01/2005 18:00:00 4 0.5 5.3 2.6 4.1 0.5 5.3 2.6 242 12 247 305 7.1 0 7.4 6.9 07/01/2005 18:10:00 3.9 0.5 5.3 2.6 3.8 0.6 5.7 2.3 228 7 227 305 7.2 0.1 7.7 7.2 07/01/2005 18:20:00 3.2 0.6 4.6 1.9 3.3 0.6 4.6 1.9 236 11 237 305 7.3 0 7.7 7.2 07/01/2005 18:30:00 3.7 0.7 5.3 2.3 3.7 0.7 4.9 1.9 235 8 244 305 7.2 0.1 7.7 6.9 07/01/2005 18:40:00 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.3 232 8 238 305 7 0 7.2 6.9 07/01/2005 18:50:00 3.6 0.5 4.9 2.3 3.5 0.4 4.9 2.3 236 13 264 305 6.9 0 7.4 6.7 07/01/2005 19:00:00 3.3 0.5 4.6 2.3 3.2 0.4 4.6 2.3 241 12 242 305 7 0 7.7 6.9 07/01/2005 19:10:00 3.2 0.5 4.6 1.9 3.3 0.5 4.6 2.3 226 12 211 305 6.8 0.1 7.4 6.7 07/01/2005 19:20:00 3.1 0.5 4.2 2.3 3.2 0.5 4.6 2.3 226 12 237 305 7 0.1 7.7 6.9 07/01/2005 19:30:00 3 0.5 4.2 1.5 3 0.5 4.2 1.9 227 15 244 305 6.8 0.1 7.4 6.7 07/01/2005 19:40:00 3.1 0.5 4.2 2.3 3.2 0.4 4.2 1.9 225 8 221 305 6.7 0.1 7.2 6.4 07/01/2005 19:50:00 3.3 0.5 4.6 1.9 3.2 0.6 4.6 1.5 240 13 233 305 6.8 0.1 7.2 6.7 07/01/2005 20:00:00 2.7 0.6 4.2 1.1 2.8 0.5 4.2 1.9 242 13 245 305 6.5 0 7.2 6.1 07/01/2005 20:10:00 2.7 0.5 3.8 1.5 2.8 0.5 4.2 1.5 228 17 219 305 6.7 0.2 7.4 6.4 07/01/2005 20:20:00 2.4 0.4 3.4 1.5 2.5 0.4 3.8 1.5 249 14 257 305 6.5 0.1 7.2 6.1 07/01/2005 20:30:00 1.6 0.7 3 0.4 1.8 0.5 3 0.7 252 15 252 305 6.5 0.1 7.2 6.1 07/01/2005 20:40:00 1.7 0.6 3 0.4 1.9 0.4 2.6 0.7 261 15 259 305 6.6 0.1 7.2 6.4 07/01/2005 20:50:00 1.4 0.8 3 0.4 1.6 0.8 3 0.4 290 32 350 305 6.4 0 7.2 6.1 07/01/2005 21:00:00 2.5 1 4.2 0.4 2.8 0.8 4.6 1.1 333 11 333 305 6.4 0.1 6.9 6.1 07/01/2005 21:10:00 1.9 0.5 3 0.7 2.3 0.4 3.4 1.1 346 8 348 305 6.3 0.1 6.9 6.1 07/01/2005 21:20:00 2.8 0.7 4.2 1.5 2.9 0.6 4.2 1.9 1 9 13 305 6.3 0 6.7 6.1 07/01/2005 21:30:00 4.6 0.4 5.7 3.8 4.7 0.4 5.7 3.4 12 8 10 305 6.3 0 6.4 6.1 07/01/2005 21:40:00 5 1 6.8 3.4 5.1 1 7.2 3.8 22 5 21 305 6.2 0.1 6.4 5.9 07/01/2005 21:50:00 6.4 0.3 6.8 5.7 6.5 0.3 7.6 5.7 30 4 24 305 5.8 0 5.9 5.6 07/01/2005 22:00:00 6.7 0.5 7.6 5.3 6.7 0.5 7.6 5.3 44 5 46 305 5.4 0.2 5.9 4.9 07/01/2005 22:10:00 8.9 1.1 11.5 6.5 8.9 1.1 11.5 6.8 44 3 47 305 4.9 0 5.4 4.7 07/01/2005 22:20:00 9.7 0.6 11.1 7.6 9.9 0.5 11.1 8 49 4 45 305 4.8 0 4.9 4.7 07/01/2005 22:30:00 8.9 0.8 11.5 6.8 9 0.8 11.1 6.8 54 6 53 305 5.1 0 5.4 4.9 07/01/2005 22:40:00 8.3 0.8 10.7 6.1 8.5 0.7 10.7 6.1 52 9 53 305 5.4 0 5.6 5.2 07/01/2005 22:50:00 8.1 1.2 11.1 4.9 8.2 1.2 11.1 4.9 56 14 58 305 5.8 0.1 6.1 5.4 07/01/2005 23:00:00 8.3 1 11.1 5.7 8.5 1 10.7 6.1 51 10 62 305 5.8 0 5.9 5.6 07/01/2005 23:10:00 7.9 1.2 10.7 4.2 8 1.2 10.3 4.6 58 12 53 305 5.5 0 5.9 5.4 07/01/2005 23:20:00 8.2 0.6 9.5 5.7 8.2 0.7 9.5 6.5 58 7 50 305 5.4 0 5.6 5.4 07/01/2005 23:30:00 7.5 0.6 9.1 5.7 7.4 0.6 9.1 5.7 58 6 58 305 5.4 0 5.6 5.4 07/01/2005 23:40:00 7.4 0.5 8.8 6.1 7.4 0.5 9.1 6.1 59 5 53 305 5.5 0 5.6 5.4 07/01/2005 23:50:00 7.4 0.4 8.8 6.5 7.4 0.4 8.4 6.1 58 4 54 305 5.4 0 5.6 5.4 07/02/2005 00:00:00 7.2 0.5 8.4 5.7 7.1 0.5 8.4 4.9 62 3 53 305 5.3 0 5.9 5.2 07/02/2005 00:10:00 6.5 0.6 7.6 4.9 6.3 0.7 7.6 4.2 57 6 67 305 5.2 0 5.4 4.9 07/02/2005 00:20:00 6 0.4 6.8 4.9 5.9 0.5 6.8 4.6 60 5 56 305 5 0 5.4 4.9 07/02/2005 00:30:00 5.9 0.5 6.8 3.8 5.7 0.6 6.8 4.2 60 5 63 305 5 0 5.2 4.9 07/02/2005 00:40:00 6.3 0.3 6.8 5.7 6.2 0.3 7.2 5.3 57 3 56 305 4.8 0 5.2 4.7 07/02/2005 00:50:00 6.7 0.4 7.2 5.7 6.7 0.5 7.6 5.3 47 4 48 305 4.8 0 4.9 4.7 07/02/2005 01:00:00 6.7 0.3 7.2 6.1 6.7 0.3 7.6 6.1 51 3 47 305 4.8 0 4.9 4.7 07/02/2005 01:10:00 6.8 0.3 7.6 6.1 6.8 0.4 8 6.1 48 3 47 305 4.7 0 4.9 4.7 07/02/2005 01:20:00 6.8 0.3 7.6 6.1 6.8 0.3 7.6 6.1 49 3 48 305 4.7 0 4.9 4.4 07/02/2005 01:30:00 6.7 0.3 7.6 5.7 6.6 0.4 7.2 5.7 53 3 57 305 4.5 0 4.7 4.4 07/02/2005 01:40:00 7 0.4 8 5.7 7 0.4 8 5.7 53 3 55 305 4.4 0 4.4 4.4 07/02/2005 01:50:00 6.4 0.3 7.2 5.7 6.4 0.4 7.2 5.3 52 3 52 305 4.3 0 4.4 4.2 07/02/2005 02:00:00 5.5 0.4 6.1 4.6 5.5 0.3 6.1 4.6 51 3 53 305 4.2 0 4.4 4.2 07/02/2005 02:10:00 6.3 0.3 7.2 5.3 6.3 0.4 7.2 4.9 50 7 53 305 4 0 4.4 3.7 07/02/2005 02:20:00 5.7 0.4 6.8 4.6 5.8 0.4 6.8 4.6 56 5 58 305 3.8 0 4.2 3.7 07/02/2005 02:30:00 5.4 0.4 6.8 4.6 5.4 0.4 6.5 4.2 50 8 42 305 3.6 0 3.7 3.4 07/02/2005 02:40:00 5.9 0.5 7.2 4.6 6 0.6 7.6 4.9 48 7 49 305 3.4 0 3.7 3.2 07/02/2005 02:50:00 5.6 0.6 6.8 4.2 5.6 0.7 6.8 3.8 49 8 56 305 3.4 0 3.7 3.2 07/02/2005 03:00:00 5.5 0.5 6.8 4.6 5.6 0.5 7.2 4.2 42 6 43 305 3.4 0 3.7 3.2 07/02/2005 03:10:00 5.4 0.5 6.8 4.2 5.4 0.5 7.2 3.8 44 5 48 305 3.4 0.1 3.7 3.2 07/02/2005 03:20:00 5.4 0.7 6.8 4.2 5.4 0.8 7.2 3.8 42 5 41 305 3.5 0 3.7 3.4 07/02/2005 03:30:00 4.9 0.5 6.1 3.8 4.9 0.5 6.1 3.8 48 5 40 305 3.6 0 3.7 3.4 07/02/2005 03:40:00 5.2 0.3 5.7 4.6 5.3 0.4 6.1 4.2 46 3 45 305 3.7 0 3.9 3.4 07/02/2005 03:50:00 5.4 0.5 6.5 4.2 5.4 0.5 6.5 4.2 40 5 40 305 3.8 0 4.2 3.7 07/02/2005 04:00:00 5.6 0.4 6.5 4.2 5.6 0.5 6.8 4.2 37 5 43 305 3.9 0 4.2 3.7 07/02/2005 04:10:00 5.2 0.4 6.5 4.2 5.3 0.4 6.5 4.2 37 5 34 305 4 0 4.4 3.9 07/02/2005 04:20:00 4.9 0.4 5.7 3.4 5 0.4 6.1 3.8 35 6 40 305 4.2 0 4.4 3.9 07/02/2005 04:30:00 5.5 0.3 6.1 4.6 5.6 0.4 6.5 4.6 25 4 20 305 4.3 0 4.4 4.2 07/02/2005 04:40:00 5.4 0.5 6.5 4.2 5.6 0.5 6.8 4.6 29 7 32 305 4.2 0 4.4 4.2 07/02/2005 04:50:00 4.9 0.4 6.1 4.2 5.1 0.3 6.1 4.2 30 8 36 305 4 0 4.4 3.9 07/02/2005 05:00:00 5 0.6 6.5 3.8 5.1 0.6 6.8 4.2 26 6 25 305 4 0.1 4.4 3.7 07/02/2005 05:10:00 4.6 0.5 5.7 3.8 4.7 0.4 5.7 3.8 28 8 45 305 4 0 4.4 3.7 07/02/2005 05:20:00 5.3 0.6 6.5 3.8 5.5 0.6 6.8 3.8 25 7 22 305 3.9 0.1 4.4 3.7 07/02/2005 05:30:00 4.6 0.5 5.7 3 4.8 0.6 6.1 3.4 30 5 32 305 3.9 0.1 4.2 3.7 07/02/2005 05:40:00 4.9 0.3 5.7 3.8 5.1 0.4 5.7 3.8 24 7 32 305 3.8 0 4.2 3.7 07/02/2005 05:50:00 5 0.5 6.1 3.8 5.1 0.5 6.1 3.8 32 3 31 305 3.8 0 4.2 3.7 07/02/2005 06:00:00 3.6 0.4 4.6 2.3 3.7 0.4 4.6 2.6 29 6 33 305 3.7 0 4.2 3.7 07/02/2005 06:10:00 3.6 0.4 4.9 2.6 3.7 0.4 4.9 2.6 29 9 35 305 3.8 0 4.2 3.7 07/02/2005 06:20:00 3.7 0.5 4.6 2.6 3.9 0.5 4.9 2.6 18 8 11 305 3.8 0 4.2 3.7 07/02/2005 06:30:00 3.5 0.4 4.6 2.6 3.7 0.4 4.6 2.6 17 6 11 305 3.9 0 4.2 3.7 07/02/2005 06:40:00 3.6 0.4 4.2 2.3 3.9 0.4 4.6 2.6 25 5 25 305 3.8 0 4.2 3.7 07/02/2005 06:50:00 3.5 0.4 4.2 2.3 3.6 0.4 4.6 2.6 28 5 31 305 3.8 0 4.2 3.7 07/02/2005 07:00:00 3.3 0.4 4.2 2.3 3.5 0.4 4.6 2.6 26 5 23 305 3.7 0 4.2 3.4 07/02/2005 07:10:00 2.8 0.4 3.4 1.9 3.1 0.4 3.8 1.9 21 7 17 305 3.7 0 4.2 3.7 07/02/2005 07:20:00 2.5 0.3 3.4 1.9 2.9 0.3 3.4 2.3 20 5 22 305 3.9 0 4.2 3.7 07/02/2005 07:30:00 2.7 0.3 3.4 1.5 3 0.3 3.8 2.3 12 4 13 305 4.2 0 4.4 3.9 07/02/2005 07:40:00 2.7 0.4 3.8 1.9 2.9 0.4 4.2 2.3 23 7 31 305 4.4 0 4.7 4.2 07/02/2005 07:50:00 2.2 0.5 3.4 0.7 2.6 0.4 3.8 1.9 18 9 4 305 4.5 0 4.9 4.4 07/02/2005 08:00:00 1.8 0.6 3 0.4 2.3 0.5 3.4 1.1 1 15 350 305 4.8 0 4.9 4.7 07/02/2005 08:10:00 1.9 0.3 2.6 0.7 2.4 0.3 3 1.5 13 10 10 305 4.9 0 5.2 4.9 07/02/2005 08:20:00 1.5 0.4 2.3 0.4 2 0.3 3 1.1 19 10 7 305 5 0.1 5.4 4.9 07/02/2005 08:30:00 1.3 0.5 2.6 0.4 1.9 0.3 2.6 1.1 22 12 18 305 5 0 5.4 4.9 07/02/2005 08:40:00 1.5 0.6 2.6 0.4 2 0.4 3 0.7 27 17 37 305 5.4 0.1 5.6 5.2 07/02/2005 08:50:00 1.2 0.6 3 0.4 1.8 0.5 3 0.7 19 19 47 305 5.9 0.1 6.1 5.6 07/02/2005 09:00:00 1.7 0.7 3.4 0.4 2.2 0.6 3.8 0.7 15 17 351 305 6.1 0 6.4 5.9 07/02/2005 09:10:00 1.8 0.7 3.4 0.4 2.1 0.6 3.8 0.7 3 14 343 305 6.5 0 6.7 6.1 07/02/2005 09:20:00 1.4 0.6 3 0.4 1.9 0.5 3 0.7 2 26 332 305 6.8 0.1 7.2 6.4 07/02/2005 09:30:00 2.1 0.6 3.4 0.4 2.4 0.6 3.4 0.7 335 12 324 305 7.3 0.1 7.7 7.2 07/02/2005 09:40:00 3.2 0.5 4.6 1.9 3.4 0.5 4.9 2.3 341 8 346 305 7.2 0 7.4 7.2 07/02/2005 09:50:00 3.9 0.6 4.9 1.5 3.9 0.5 4.9 2.3 345 6 350 305 7.5 0 7.7 7.4 07/02/2005 10:00:00 3.5 0.6 4.9 1.9 3.4 0.5 4.9 2.3 355 8 358 305 7.5 0 7.7 7.4 07/02/2005 10:10:00 3.2 0.6 4.9 1.5 3.2 0.6 4.6 1.9 359 10 358 305 7.7 0 7.9 7.4 07/02/2005 10:20:00 3.9 0.5 4.9 2.3 3.8 0.6 4.9 2.3 354 7 353 305 7.9 0 8.2 7.7 07/02/2005 10:30:00 4 0.4 5.3 2.6 3.9 0.5 4.9 2.6 352 5 358 305 7.8 0 7.9 7.7 07/02/2005 10:40:00 3.4 0.5 4.6 2.3 3.4 0.5 4.9 1.9 1 8 0 305 8 0 8.2 7.7 07/02/2005 10:50:00 2.8 0.5 3.8 1.5 3.1 0.4 4.2 2.3 17 9 13 305 8 0 8.2 7.7 07/02/2005 11:00:00 3 0.6 4.6 1.1 3.1 0.4 4.2 1.9 24 11 21 305 8.1 0 8.2 7.9 07/02/2005 11:10:00 4 0.6 4.9 2.3 4 0.6 5.3 2.6 15 9 17 305 8.1 0 8.4 7.9 07/02/2005 11:20:00 4.6 0.4 5.7 3.4 4.5 0.4 5.3 3.4 22 7 36 305 8.3 0.1 8.7 7.9 07/02/2005 11:30:00 4.8 0.4 5.7 3.8 4.7 0.4 5.7 3.8 30 7 25 305 8.2 0.1 8.4 7.9 07/02/2005 11:40:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 29 6 32 305 8.1 0 8.2 7.9 07/02/2005 11:50:00 4.2 0.4 4.9 3 4.2 0.4 4.9 3.4 24 5 23 305 8.3 0.1 8.7 8.2 07/02/2005 12:00:00 4.5 0.4 5.3 3 4.5 0.4 5.7 3 28 6 23 305 8.6 0 9.2 8.4 07/02/2005 12:10:00 4.2 0.4 5.3 3 4.3 0.4 5.3 3.4 35 7 47 305 8.4 0 8.9 8.2 07/02/2005 12:20:00 4.3 0.3 5.3 3.4 4.3 0.4 4.9 3.4 34 6 36 305 8.4 0.1 9.2 8.2 07/02/2005 12:30:00 5 0.6 6.1 3.4 5 0.5 6.1 3 35 6 35 305 8.7 0.2 9.5 8.2 07/02/2005 12:40:00 6.6 0.6 7.6 4.6 6.3 0.6 7.6 4.6 31 4 27 305 8.9 0.2 9.5 8.4 07/02/2005 12:50:00 7.4 0.4 8.4 6.1 7.3 0.6 8.4 5.3 37 4 40 305 8.8 0.2 9.2 8.4 07/02/2005 13:00:00 6.8 0.4 7.6 5.7 6.6 0.5 7.6 5.3 41 4 39 305 8.6 0.2 9.5 8.2 07/02/2005 13:10:00 6.2 0.4 7.2 4.9 6 0.5 7.2 4.6 47 5 46 305 8.2 0.2 9.2 7.9 07/02/2005 13:20:00 6.9 0.6 8.4 5.3 6.8 0.7 8.4 5.3 52 4 50 305 8.6 0.2 9.5 8.2 07/02/2005 13:30:00 7.1 0.5 8.4 5.3 7 0.6 8.4 4.9 54 5 52 305 8.4 0.1 9.2 8.2 07/02/2005 13:40:00 7.2 0.4 8 5.7 7.1 0.4 8 5.7 54 4 61 305 8.3 0.1 8.9 7.9 07/02/2005 13:50:00 7.5 0.4 8.4 6.5 7.4 0.4 8 6.1 57 4 51 305 8.4 0.2 9.2 8.2 07/02/2005 14:00:00 7.4 0.4 8 6.1 7.4 0.4 8.4 6.1 55 4 58 305 8.4 0.2 9.2 7.9 07/02/2005 14:10:00 7.6 0.4 8.8 6.5 7.5 0.5 8.8 6.5 56 5 59 305 8.3 0.2 9.2 8.2 07/02/2005 14:20:00 7.1 0.5 8.4 5.3 7.1 0.5 8 5.7 57 5 52 305 8.4 0.1 9.2 8.2 07/02/2005 14:30:00 7.1 0.4 8 6.1 7 0.4 8 5.7 57 5 56 305 8.2 0.2 9.2 7.9 07/02/2005 14:40:00 7.1 0.4 8 6.1 7 0.4 8 5.7 55 5 52 305 8.4 0.1 8.9 8.2 07/02/2005 14:50:00 7.4 0.5 8.8 5.7 7.3 0.5 8.4 6.1 57 5 64 305 8.5 0.1 9.2 8.2 07/02/2005 15:00:00 6.9 0.4 8.4 5.3 6.8 0.4 7.6 5.7 55 5 62 305 8.6 0.1 9.5 8.2 07/02/2005 15:10:00 6.6 0.4 7.6 4.9 6.6 0.5 7.6 5.3 52 6 57 305 8.4 0 8.9 8.2 07/02/2005 15:20:00 6.4 0.5 7.6 4.9 6.4 0.5 7.2 5.3 49 5 51 305 8.2 0 8.7 7.9 07/02/2005 15:30:00 6.9 0.4 8 5.7 6.9 0.4 8.4 5.7 57 5 50 305 8.5 0 8.9 8.2 07/02/2005 15:40:00 7.4 0.4 8.4 6.1 7.3 0.5 8.4 5.7 53 4 54 305 8.6 0.3 9.2 8.2 07/02/2005 15:50:00 7.5 0.5 8.4 5.7 7.4 0.5 8.4 5.7 55 5 57 305 8.6 0 9.2 8.4 07/02/2005 16:00:00 7.9 0.6 9.5 6.1 8 0.6 9.5 6.1 51 6 43 305 8.5 0.2 9.2 8.2 07/02/2005 16:10:00 7.2 0.7 9.1 5.3 7.3 0.7 9.5 5.7 49 6 62 305 8.7 0.1 9.2 8.2 07/02/2005 16:20:00 8 0.8 9.9 6.1 8.2 0.7 9.9 6.5 46 8 62 305 8.8 0.1 9.2 8.4 07/02/2005 16:30:00 8.3 0.7 10.3 6.1 8.4 0.7 10.3 5.7 53 7 65 305 8.6 0.2 9.2 8.2 07/02/2005 16:40:00 8.8 0.8 11.1 5.3 8.8 0.8 11.1 5.7 49 6 61 305 8.1 0.2 8.9 7.7 07/02/2005 16:50:00 8.4 0.5 9.9 6.5 8.5 0.5 9.9 6.8 53 6 58 305 8.2 0.2 9.2 7.7 07/02/2005 17:00:00 8.2 0.7 9.9 6.5 8.3 0.7 9.9 5.7 48 5 50 305 8.2 0.1 8.7 7.9 07/02/2005 17:10:00 8.4 0.5 9.9 6.8 8.6 0.5 10.3 7.2 46 3 48 305 8.1 0 8.7 7.9 07/02/2005 17:20:00 8.6 0.4 9.5 7.6 8.6 0.3 9.5 7.6 48 3 52 305 8 0.1 8.7 7.7 07/02/2005 17:30:00 8.8 0.5 9.9 7.2 8.9 0.5 10.3 7.2 47 4 44 305 7.5 0.1 8.2 7.4 07/02/2005 17:40:00 8.2 0.4 9.1 7.2 8.1 0.4 9.1 6.5 49 3 49 305 7 0.1 7.4 6.7 07/02/2005 17:50:00 7.1 0.6 8.4 5.3 6.9 0.6 8 4.9 57 5 54 305 6.8 0.2 7.7 6.4 07/02/2005 18:00:00 6 0.7 7.6 4.2 5.9 0.7 7.2 4.2 55 6 60 305 6.9 0.1 7.7 6.7 07/02/2005 18:10:00 5.1 0.5 6.5 3.8 5 0.5 6.5 3.8 45 9 56 305 6.3 0.2 6.9 5.9 07/02/2005 18:20:00 5.2 0.7 6.5 3.8 5.2 0.7 6.5 3.8 42 8 36 305 6 0 6.1 5.9 07/02/2005 18:30:00 6 0.5 6.8 4.6 5.9 0.5 6.8 4.6 39 4 46 305 6 0 6.1 5.9 07/02/2005 18:40:00 6 0.3 6.8 5.3 6 0.4 7.2 4.6 37 3 41 305 6.1 0 6.1 5.9 07/02/2005 18:50:00 5.7 0.2 6.1 4.9 5.7 0.3 6.5 4.9 31 4 34 305 6 0 6.1 5.9 07/02/2005 19:00:00 6 0.4 6.8 4.6 5.7 0.5 6.8 4.6 39 5 40 305 5.8 0 5.9 5.6 07/02/2005 19:10:00 6 0.7 7.6 3.4 5.8 0.7 7.6 3.4 37 3 39 305 6 0 6.4 5.9 07/02/2005 19:20:00 5.3 0.5 6.5 3.4 5.1 0.6 6.5 3.4 31 3 27 305 6 0 6.1 5.9 07/02/2005 19:30:00 4.8 0.5 6.1 3 4.6 0.7 6.1 3.4 35 5 39 305 6.1 0 6.4 5.9 07/02/2005 19:40:00 4.5 0.3 5.7 3.8 4.4 0.4 5.7 3.4 38 6 39 305 6.1 0.1 6.4 5.9 07/02/2005 19:50:00 4.9 0.4 6.1 4.2 4.8 0.4 5.7 3.8 40 4 37 305 5.9 0 6.1 5.9 07/02/2005 20:00:00 4.4 0.4 5.3 3 4.4 0.4 5.7 3 52 6 61 305 6.1 0.1 6.4 5.6 07/02/2005 20:10:00 5 0.5 6.1 3.8 5 0.5 6.1 3.8 54 4 54 305 6.1 0.1 6.4 5.9 07/02/2005 20:20:00 4.4 0.3 5.3 3.4 4.3 0.4 5.3 3.4 51 5 61 305 6 0 6.4 5.9 07/02/2005 20:30:00 4.3 0.4 5.3 3 4.3 0.5 5.3 3 49 4 46 305 5.9 0 6.1 5.6 07/02/2005 20:40:00 4 0.5 5.3 2.6 3.9 0.5 5.3 2.6 41 6 36 305 5.6 0.1 5.9 5.4 07/02/2005 20:50:00 5.5 0.6 6.5 3.4 5.5 0.8 6.5 3 26 4 24 305 5.6 0 5.9 5.4 07/02/2005 21:00:00 5.9 0.3 6.8 4.9 6 0.4 7.2 5.3 22 3 27 305 5.6 0.1 5.9 5.4 07/02/2005 21:10:00 5.4 0.3 6.1 4.6 5.5 0.4 6.5 4.2 17 3 21 305 5.5 0 5.6 5.4 07/02/2005 21:20:00 5.6 0.3 6.5 4.9 5.7 0.4 6.5 4.6 29 3 27 305 5.5 0 5.6 5.4 07/02/2005 21:30:00 5.8 0.4 6.8 4.6 5.7 0.5 6.8 4.2 34 4 29 305 5.4 0 5.6 5.4 07/02/2005 21:40:00 5.3 0.5 6.5 4.2 5.3 0.6 6.5 3.8 37 4 35 305 5.3 0 5.4 5.2 07/02/2005 21:50:00 5.4 0.4 6.1 4.2 5.4 0.5 6.1 3.8 41 5 45 305 5.3 0 5.4 5.2 07/02/2005 22:00:00 5.7 0.4 6.5 4.6 5.7 0.4 6.5 4.9 32 5 38 305 5.3 0 5.4 5.2 07/02/2005 22:10:00 6.1 0.7 7.6 4.9 6.1 0.7 7.6 4.9 30 4 27 305 5.3 0 5.4 5.2 07/02/2005 22:20:00 6.1 0.6 7.2 4.9 6.1 0.6 7.6 4.9 31 6 27 305 5.2 0 5.4 4.9 07/02/2005 22:30:00 7.3 0.5 9.1 6.5 7.4 0.6 9.1 6.1 34 7 34 305 5.2 0 5.4 4.9 07/02/2005 22:40:00 6.4 0.6 8.4 5.3 6.5 0.6 8.4 4.9 33 5 35 305 5.1 0 5.4 4.9 07/02/2005 22:50:00 6.8 0.4 8 5.3 6.8 0.4 7.6 5.3 39 4 47 305 5 0 5.4 4.9 07/02/2005 23:00:00 6.4 0.3 7.2 5.7 6.6 0.4 7.6 5.3 25 5 37 305 4.8 0 5.2 4.9 07/02/2005 23:10:00 6 0.4 6.8 4.6 6.1 0.4 6.8 4.6 22 3 25 305 4.8 0 4.9 4.7 07/02/2005 23:20:00 6.6 0.5 7.6 5.7 6.7 0.5 7.6 5.3 33 5 35 305 4.8 0 4.9 4.7 07/02/2005 23:30:00 6.8 0.3 7.6 6.1 6.7 0.3 7.6 5.3 37 2 40 305 4.8 0 4.9 4.7 07/02/2005 23:40:00 6.4 0.5 7.6 5.3 6.3 0.6 7.6 4.6 31 4 27 305 4.8 0 4.9 4.7 07/02/2005 23:50:00 7.4 0.5 8.4 6.5 7.5 0.6 8.8 6.1 31 3 30 305 4.8 0 4.9 4.7 07/03/2005 00:00:00 7.3 0.5 8.4 6.1 7.3 0.5 8.8 6.1 35 5 30 305 4.8 0 5.4 4.7 07/03/2005 00:10:00 6.2 0.3 6.8 5.3 6.3 0.3 7.2 5.3 33 5 27 305 4.8 0 4.9 4.7 07/03/2005 00:20:00 7 0.5 8 5.7 7.1 0.5 8 5.7 35 3 36 305 4.8 0 4.9 4.7 07/03/2005 00:30:00 7.3 0.4 8.4 6.5 7.3 0.4 8.4 6.5 34 2 35 305 4.8 0 4.9 4.7 07/03/2005 00:40:00 6.1 0.5 7.2 5.3 6.2 0.5 7.6 5.3 30 4 33 305 4.8 0 4.9 4.7 07/03/2005 00:50:00 6.3 0.5 7.6 5.3 6.4 0.5 7.6 5.3 29 3 34 305 4.8 0 5.2 4.7 07/03/2005 01:00:00 6.5 0.4 7.6 5.7 6.6 0.4 7.6 5.7 37 4 32 305 4.8 0 5.2 4.7 07/03/2005 01:10:00 6.7 0.4 7.6 5.7 6.7 0.4 7.6 5.7 35 4 35 305 4.9 0 5.2 4.9 07/03/2005 01:20:00 6.5 0.3 7.2 5.7 6.5 0.3 7.2 5.7 37 4 33 305 4.9 0 5.2 4.9 07/03/2005 01:30:00 6.2 0.4 7.2 5.3 6.2 0.4 7.2 5.3 41 3 47 305 4.8 0 5.2 4.7 07/03/2005 01:40:00 6.3 0.4 7.2 5.3 6.3 0.4 7.6 5.3 38 5 35 305 4.8 0 5.2 4.7 07/03/2005 01:50:00 5.9 0.4 6.8 4.9 5.8 0.4 6.8 4.6 35 5 29 305 4.8 0 5.2 4.7 07/03/2005 02:00:00 5.7 0.5 6.5 4.6 5.7 0.5 6.5 4.6 36 4 40 305 4.8 0 5.2 4.7 07/03/2005 02:10:00 5.3 0.4 6.5 4.2 5.3 0.5 6.5 4.2 33 5 36 305 4.8 0 5.2 4.7 07/03/2005 02:20:00 5.1 0.6 6.1 3.4 5.2 0.6 6.1 3.4 33 5 33 305 4.9 0 5.2 4.9 07/03/2005 02:30:00 5.4 0.4 6.1 4.2 5.5 0.4 6.5 3.8 26 3 27 305 4.9 0 5.4 4.9 07/03/2005 02:40:00 5.8 0.6 6.8 4.6 5.9 0.7 7.2 4.6 28 3 23 305 4.9 0 5.4 4.9 07/03/2005 02:50:00 5.6 0.6 6.5 4.6 5.6 0.5 6.5 4.2 30 3 30 305 4.8 0 5.2 4.7 07/03/2005 03:00:00 5.3 0.4 6.1 4.6 5.4 0.4 6.5 4.6 26 5 23 305 4.8 0 4.9 4.7 07/03/2005 03:10:00 4.8 0.4 6.1 4.2 4.9 0.4 6.1 4.2 20 7 31 305 4.8 0 5.2 4.7 07/03/2005 03:20:00 4.9 0.5 5.7 3.8 5.1 0.5 6.1 4.2 24 6 18 305 4.7 0 4.9 4.7 07/03/2005 03:30:00 5.7 0.4 6.8 4.6 5.8 0.4 6.8 4.6 36 5 40 305 4.4 0.1 4.9 4.4 07/03/2005 03:40:00 5.8 0.5 6.8 4.9 5.9 0.5 6.8 4.6 27 4 24 305 4.4 0 4.7 4.2 07/03/2005 03:50:00 5.8 0.4 6.8 4.6 5.9 0.5 6.8 4.6 36 5 29 305 4.3 0 4.7 4.2 07/03/2005 04:00:00 5.5 0.4 6.5 4.6 5.6 0.4 6.5 4.6 38 4 36 305 4.2 0 4.7 4.2 07/03/2005 04:10:00 6.1 0.4 7.2 5.3 6.2 0.4 7.2 5.3 31 4 32 305 4.3 0 4.7 4.2 07/03/2005 04:20:00 6.2 0.4 7.2 4.9 6.2 0.4 7.2 4.9 28 3 30 305 4.3 0 4.7 4.2 07/03/2005 04:30:00 5.7 0.4 6.8 4.6 5.7 0.5 7.2 4.6 28 6 21 305 4.4 0 4.7 4.2 07/03/2005 04:40:00 5.5 0.5 6.8 4.6 5.6 0.5 6.5 4.6 25 4 28 305 4.5 0.1 4.9 4.4 07/03/2005 04:50:00 5.3 0.4 6.1 4.2 5.4 0.4 6.5 4.2 19 5 24 305 4.4 0.1 4.9 4.4 07/03/2005 05:00:00 5.6 0.4 6.8 4.6 5.7 0.4 6.8 4.6 23 7 14 305 4.4 0 4.7 4.2 07/03/2005 05:10:00 5.5 0.5 6.8 4.6 5.5 0.5 6.5 4.6 19 3 16 305 4.4 0 4.7 4.2 07/03/2005 05:20:00 5.8 0.5 7.2 4.9 5.9 0.5 7.2 4.9 19 4 16 305 4.4 0.1 4.9 4.4 07/03/2005 05:30:00 5.6 0.6 6.8 4.2 5.7 0.5 6.8 4.6 24 5 30 305 4.4 0.1 4.9 4.4 07/03/2005 05:40:00 6 0.4 6.8 4.9 6 0.4 6.8 4.9 25 4 26 305 4.5 0.1 4.9 4.4 07/03/2005 05:50:00 5.5 0.4 6.1 4.6 5.5 0.4 6.5 4.2 23 4 19 305 4.5 0.1 4.9 4.4 07/03/2005 06:00:00 5.5 0.3 6.5 4.9 5.6 0.3 6.5 4.9 28 4 32 305 4.5 0.1 4.9 4.4 07/03/2005 06:10:00 5.6 0.3 6.5 4.9 5.7 0.3 6.5 4.9 30 5 32 305 4.5 0.1 4.9 4.4 07/03/2005 06:20:00 5.7 0.5 6.8 4.9 5.7 0.4 6.8 4.9 27 4 22 305 4.5 0.1 4.9 4.4 07/03/2005 06:30:00 6.1 0.3 6.8 5.3 6.1 0.3 6.8 5.3 25 6 21 305 4.7 0 4.9 4.4 07/03/2005 06:40:00 5.6 0.3 6.5 4.9 5.6 0.3 6.5 4.9 21 3 24 305 4.6 0.1 4.9 4.4 07/03/2005 06:50:00 5.6 0.3 6.5 4.6 5.8 0.3 6.8 4.9 12 4 11 305 4.6 0 4.9 4.4 07/03/2005 07:00:00 5.7 0.3 6.5 4.9 5.9 0.4 6.8 4.9 10 5 15 305 4.5 0 4.9 4.4 07/03/2005 07:10:00 5.9 0.8 7.2 4.2 5.9 0.7 7.2 4.6 32 4 32 305 4.6 0 4.9 4.4 07/03/2005 07:20:00 6.7 0.4 7.6 5.7 6.7 0.4 8 5.3 32 2 34 305 4.7 0 4.9 4.4 07/03/2005 07:30:00 6.2 0.4 7.2 5.3 6.2 0.5 7.6 4.6 26 5 25 305 4.7 0 4.9 4.4 07/03/2005 07:40:00 6.3 0.3 6.8 5.7 6.3 0.3 7.2 5.3 28 3 29 305 4.7 0 5.2 4.7 07/03/2005 07:50:00 6.5 0.4 7.6 5.7 6.5 0.4 7.6 5.7 35 5 32 305 4.7 0 5.2 4.7 07/03/2005 08:00:00 6.4 0.4 7.2 5.7 6.4 0.4 7.2 4.9 34 5 31 305 4.8 0 5.2 4.7 07/03/2005 08:10:00 6.9 0.4 8 6.1 6.8 0.4 7.6 5.7 39 5 35 305 4.8 0 5.2 4.7 07/03/2005 08:20:00 7.9 0.7 9.9 6.5 7.9 0.7 9.9 6.5 38 4 35 305 4.9 0 5.2 4.7 07/03/2005 08:30:00 8.2 0.4 9.5 7.2 8.1 0.5 9.1 6.8 39 4 35 305 4.8 0 5.2 4.7 07/03/2005 08:40:00 8.2 0.6 9.5 6.5 8 0.6 9.5 6.1 41 5 36 305 4.8 0 5.4 4.7 07/03/2005 08:50:00 8.4 0.5 10.3 6.8 8.3 0.5 9.9 6.8 39 5 42 305 4.8 0 5.2 4.7 07/03/2005 09:00:00 8.2 0.4 9.1 7.2 8.1 0.5 9.5 6.5 41 5 45 305 4.8 0 5.2 4.7 07/03/2005 09:10:00 7.5 0.5 8.8 6.5 7.4 0.5 9.1 5.7 42 5 44 305 4.8 0 5.2 4.7 07/03/2005 09:20:00 7.9 0.8 9.5 6.1 7.7 0.8 9.5 6.1 39 6 35 305 4.8 0 5.4 4.7 07/03/2005 09:30:00 8.1 0.5 9.1 7.2 8.1 0.4 9.1 6.8 37 5 44 305 4.9 0 5.4 4.9 07/03/2005 09:40:00 8.5 0.7 10.7 6.8 8.4 0.7 10.3 6.8 34 5 37 305 5 0.1 5.4 4.9 07/03/2005 09:50:00 8.6 0.6 9.9 6.8 8.5 0.7 9.9 6.5 31 5 32 305 5.2 0 5.6 4.9 07/03/2005 10:00:00 8.9 0.8 10.7 6.8 8.9 0.8 11.1 6.8 26 5 21 305 5.3 0 5.6 5.2 07/03/2005 10:10:00 9.3 0.5 10.7 8.4 9.3 0.5 11.1 8 30 5 39 305 5.3 0 5.6 5.2 07/03/2005 10:20:00 8.9 0.9 11.1 7.2 8.9 0.8 11.1 7.2 28 5 22 305 5.4 0 5.6 5.2 07/03/2005 10:30:00 9.1 0.7 11.5 6.8 9.1 0.7 11.5 6.5 21 4 21 305 5.4 0 5.6 5.4 07/03/2005 10:40:00 8.9 0.6 10.3 7.2 8.9 0.6 10.3 6.8 22 5 24 305 5.4 0 5.9 5.4 07/03/2005 10:50:00 9.9 0.8 11.8 7.6 9.8 0.9 11.8 7.6 23 4 21 305 5.4 0 5.9 5.4 07/03/2005 11:00:00 9.7 0.6 11.1 8.4 9.6 0.6 11.1 8 24 4 29 305 5.4 0 5.6 5.2 07/03/2005 11:10:00 10.1 0.5 11.5 8.4 10.1 0.6 11.5 8 19 4 21 305 5.4 0 5.6 5.2 07/03/2005 11:20:00 9.8 0.6 11.1 8 9.8 0.6 11.1 8 19 3 17 305 5.4 0 5.6 5.4 07/03/2005 11:30:00 9.5 0.6 10.7 8 9.5 0.6 10.7 8 25 5 22 305 5.5 0 5.9 5.4 07/03/2005 11:40:00 9.2 0.7 11.1 7.6 9.1 0.8 11.5 6.1 27 4 22 305 5.6 0 5.9 5.4 07/03/2005 11:50:00 9 0.5 10.3 7.6 8.8 0.7 10.3 7.2 25 5 21 305 5.9 0 6.1 5.6 07/03/2005 12:00:00 9.4 0.6 11.1 8.4 9.5 0.6 11.1 8 21 3 20 305 5.9 0 5.9 5.9 07/03/2005 12:10:00 8.8 0.6 10.3 7.6 8.8 0.6 10.3 7.2 22 4 14 305 5.9 0 6.1 5.9 07/03/2005 12:20:00 8.8 0.8 10.3 6.8 8.8 0.8 10.7 6.5 23 5 18 305 6 0 6.1 5.9 07/03/2005 12:30:00 9.1 0.6 10.7 7.6 9 0.7 10.7 6.8 25 3 31 305 6 0 6.4 5.9 07/03/2005 12:40:00 9.6 0.6 11.1 8 9.5 0.6 11.1 8 25 4 26 305 6.1 0 6.4 5.9 07/03/2005 12:50:00 9 0.6 10.7 6.5 9 0.6 10.7 6.8 32 5 31 305 6.4 0.1 6.9 5.9 07/03/2005 13:00:00 8.7 0.7 9.9 7.2 8.6 0.7 9.9 6.5 31 4 34 305 6.6 0.1 6.9 6.1 07/03/2005 13:10:00 8.8 0.7 10.7 6.5 8.7 0.7 9.9 6.1 33 3 32 305 6.8 0 7.2 6.7 07/03/2005 13:20:00 8.4 0.5 9.9 6.8 8.3 0.6 9.9 6.5 38 5 33 305 7.2 0.1 7.7 6.9 07/03/2005 13:30:00 8 0.4 9.1 6.5 7.9 0.5 9.1 6.5 37 5 35 305 7.4 0.2 7.9 7.2 07/03/2005 13:40:00 7.9 0.4 8.8 6.8 7.7 0.5 8.8 6.5 30 3 31 305 7.7 0 7.9 7.4 07/03/2005 13:50:00 7.9 0.6 8.8 6.1 7.8 0.6 9.1 6.1 29 4 33 305 7.6 0 8.2 7.4 07/03/2005 14:00:00 7.4 0.6 8.8 5.7 7.3 0.6 8.8 5.7 34 4 32 305 7.7 0.1 8.2 7.4 07/03/2005 14:10:00 7.1 0.6 8.4 5.3 7 0.6 8.8 5.3 28 4 29 305 7.8 0.1 8.2 7.4 07/03/2005 14:20:00 6.6 0.5 8 5.3 6.5 0.5 8 4.9 28 4 32 305 7.4 0 7.9 7.2 07/03/2005 14:30:00 6.4 0.5 7.6 4.6 6.3 0.6 7.6 4.6 30 4 32 305 7.3 0 7.7 7.2 07/03/2005 14:40:00 6.3 0.6 7.6 4.6 6.2 0.6 7.6 4.9 31 3 33 305 7.6 0 7.7 7.4 07/03/2005 14:50:00 5.1 0.5 6.5 3.8 5 0.5 6.5 3.8 37 7 25 305 7.5 0.2 7.9 7.2 07/03/2005 15:00:00 5.7 0.5 7.2 4.6 5.7 0.5 7.2 4.2 38 7 28 305 7.5 0 7.7 7.2 07/03/2005 15:10:00 5.8 0.5 6.8 4.6 5.8 0.5 6.8 4.2 30 4 24 305 7.7 0 7.9 7.4 07/03/2005 15:20:00 5.8 0.3 6.8 4.9 5.7 0.4 6.8 4.6 39 6 42 305 7.7 0 8.2 7.7 07/03/2005 15:30:00 5.5 0.4 6.8 4.2 5.5 0.5 6.8 4.6 47 5 34 305 7.9 0.2 8.2 7.4 07/03/2005 15:40:00 5.2 0.5 6.8 4.2 5.2 0.5 6.8 3.8 49 6 37 305 7.1 0 7.7 7.2 07/03/2005 15:50:00 5.8 0.5 6.8 4.2 5.7 0.5 6.8 4.6 51 7 52 305 7 0 7.4 6.9 07/03/2005 16:00:00 5.8 0.4 6.8 4.6 5.7 0.4 6.8 4.6 57 7 62 305 6.9 0 7.2 6.7 07/03/2005 16:10:00 6.4 0.4 7.2 5.3 6.3 0.4 7.2 4.9 54 6 61 305 7.2 0.2 7.9 6.9 07/03/2005 16:20:00 6.8 0.4 7.6 5.3 6.7 0.5 8 5.3 47 5 47 305 7.2 0.1 7.9 6.9 07/03/2005 16:30:00 7.1 0.4 8 5.7 7 0.5 8 5.7 45 4 43 305 7.1 0.1 7.7 6.9 07/03/2005 16:40:00 6.4 0.7 8 4.6 6.2 0.7 7.6 4.6 44 7 50 305 7.4 0.1 8.2 7.2 07/03/2005 16:50:00 6.2 0.4 7.2 4.9 6.1 0.4 6.8 4.6 38 5 31 305 7.2 0.2 7.9 7.2 07/03/2005 17:00:00 6 0.5 7.2 4.6 6 0.5 7.2 4.9 35 5 33 305 7 0.1 7.7 6.9 07/03/2005 17:10:00 6.1 0.5 7.2 4.6 6 0.5 7.2 4.6 33 4 31 305 7.2 0.1 7.7 7.2 07/03/2005 17:20:00 5.7 0.5 7.2 4.2 5.6 0.5 6.8 4.2 31 4 36 305 7 0 7.4 6.9 07/03/2005 17:30:00 5.2 0.5 6.5 3.8 5.2 0.5 6.8 3.8 23 3 23 305 6.5 0.1 7.2 6.1 07/03/2005 17:40:00 5.3 0.4 6.1 4.2 5.1 0.5 6.1 3.4 28 5 24 305 6.4 0 7.2 6.1 07/03/2005 17:50:00 5.2 0.5 6.1 4.2 5 0.5 6.5 3.8 20 3 22 305 6.7 0.1 7.2 6.4 07/03/2005 18:00:00 5.5 0.4 6.5 4.6 5.5 0.5 6.5 4.2 18 3 19 305 7.2 0.1 7.9 6.9 07/03/2005 18:10:00 5.9 0.4 6.8 4.9 6 0.4 6.8 4.9 11 5 13 305 7.1 0.1 7.7 6.9 07/03/2005 18:20:00 6 0.4 6.8 5.3 6.1 0.4 6.8 4.6 0 3 359 305 7.3 0 7.4 7.2 07/03/2005 18:30:00 6.1 0.5 7.2 4.2 5.8 0.5 7.2 3.8 357 4 6 305 7.2 0 7.7 7.2 07/03/2005 18:40:00 6.9 0.5 8 5.3 6.9 0.5 8 5.3 0 2 0 305 7.2 0 7.4 7.2 07/03/2005 18:50:00 4.9 0.7 6.1 3 4.7 0.7 6.5 2.6 352 6 358 305 7.2 0.1 7.7 6.9 07/03/2005 19:00:00 5.2 1 6.5 2.3 5.1 1 6.5 2.6 357 6 355 305 7.1 0 7.4 6.9 07/03/2005 19:10:00 5 0.4 6.1 3.8 4.9 0.5 6.1 3.8 352 4 350 305 7.2 0 7.4 7.2 07/03/2005 19:20:00 5.5 1.1 7.6 3.4 5.4 1 7.6 3.4 357 6 4 305 7.2 0 7.4 7.2 07/03/2005 19:30:00 6.1 0.4 7.2 4.9 6 0.5 7.2 4.2 355 3 2 305 7.3 0 7.7 7.2 07/03/2005 19:40:00 5.8 0.3 6.8 4.9 5.8 0.4 6.8 4.6 350 3 354 305 7 0 7.4 6.9 07/03/2005 19:50:00 5 0.3 5.7 4.2 5 0.3 6.1 3.8 355 4 348 305 7 0 7.2 6.9 07/03/2005 20:00:00 4.6 0.4 5.7 3.4 4.4 0.4 6.1 3.4 3 4 357 305 7 0 7.2 6.9 07/03/2005 20:10:00 5.4 0.6 6.8 3.4 5.1 0.6 6.5 3.4 355 6 353 305 7 0 7.4 6.9 07/03/2005 20:20:00 5.4 0.4 6.5 4.2 5.3 0.4 6.1 3.8 351 4 349 305 7.3 0 7.4 7.2 07/03/2005 20:30:00 5.2 0.5 6.8 3.8 5 0.5 6.1 3.8 1 6 15 305 7.2 0.1 7.7 6.9 07/03/2005 20:40:00 5.5 0.4 6.8 4.9 5.6 0.4 6.8 4.9 354 4 1 305 7 0 7.2 6.9 07/03/2005 20:50:00 5.8 0.3 6.5 4.9 5.7 0.5 6.5 4.2 352 5 0 305 7 0 7.2 6.9 07/03/2005 21:00:00 6.3 0.4 7.2 5.3 6.4 0.5 7.2 4.2 0 3 358 305 7 0 7.2 6.9 07/03/2005 21:10:00 6.7 0.5 8 5.7 6.7 0.5 8 5.7 5 4 9 305 6.9 0 7.2 6.7 07/03/2005 21:20:00 7.4 0.6 8.8 6.1 7.4 0.6 8.8 6.1 3 5 3 305 6.8 0 7.2 6.9 07/03/2005 21:30:00 6.4 0.4 7.6 5.3 6.4 0.5 7.6 4.9 358 4 355 305 7 0 7.2 6.9 07/03/2005 21:40:00 5.8 0.5 6.8 4.2 5.7 0.5 6.8 4.6 2 5 3 305 6.8 0 7.2 6.7 07/03/2005 21:50:00 6.4 0.4 7.6 5.3 6.4 0.5 8.4 5.3 356 3 2 305 6.6 0 6.9 6.4 07/03/2005 22:00:00 6.6 0.4 7.6 5.7 6.8 0.3 8 6.1 359 3 352 305 6.5 0 6.9 6.1 07/03/2005 22:10:00 6.3 0.5 7.6 5.3 6.4 0.4 7.6 5.3 4 3 2 305 6.3 0 6.4 6.1 07/03/2005 22:20:00 6.3 0.4 8 5.3 6.3 0.5 7.2 4.9 3 4 7 305 6.4 0 6.7 6.1 07/03/2005 22:30:00 6.5 0.6 8.8 5.3 6.6 0.6 8.4 4.9 359 7 356 305 6.1 0.1 6.7 5.9 07/03/2005 22:40:00 6.7 0.6 8 5.3 6.7 0.6 8.4 5.3 358 5 351 305 5.9 0 6.4 5.9 07/03/2005 22:50:00 6.7 0.5 8.4 5.7 6.7 0.4 8.4 5.7 359 5 359 305 5.8 0.1 6.4 5.6 07/03/2005 23:00:00 7.3 0.5 8.4 6.1 7.5 0.4 8.4 6.5 6 3 3 305 5.8 0 5.9 5.6 07/03/2005 23:10:00 7.5 0.6 8.8 6.1 7.6 0.5 8.8 6.5 17 4 15 305 5.8 0 5.9 5.6 07/03/2005 23:20:00 7.5 0.5 9.5 6.8 7.5 0.4 9.1 6.5 22 3 24 305 5.9 0 5.9 5.6 07/03/2005 23:30:00 8.1 0.7 9.9 6.5 8 0.7 9.1 6.5 18 5 25 305 5.9 0 5.9 5.6 07/03/2005 23:40:00 7.9 0.6 9.5 6.8 7.9 0.6 9.5 6.5 9 4 9 305 5.9 0 6.1 5.9 07/03/2005 23:50:00 7.9 0.7 10.3 6.5 7.8 0.7 9.9 5.7 9 4 6 305 6 0 6.1 5.9 07/04/2005 00:00:00 9.3 0.5 10.3 8 9.3 0.5 10.7 8 9 3 4 305 6 0 6.7 5.9 07/04/2005 00:10:00 7.9 0.6 9.1 6.8 8 0.6 9.1 6.8 11 3 9 305 5.9 0 6.1 5.6 07/04/2005 00:20:00 7.7 0.4 8.4 6.8 7.8 0.4 8.8 6.8 17 3 18 305 5.8 0 5.9 5.6 07/04/2005 00:30:00 7.6 0.8 9.5 6.1 7.7 0.8 9.5 6.5 11 3 9 305 5.7 0 5.9 5.6 07/04/2005 00:40:00 7.5 0.5 8.8 6.1 7.5 0.6 9.1 5.7 10 4 15 305 5.7 0 5.9 5.4 07/04/2005 00:50:00 6.4 0.6 8.4 5.3 6.6 0.6 8.4 5.3 7 4 7 305 5.7 0 5.9 5.4 07/04/2005 01:00:00 6.3 0.6 7.6 4.9 6.3 0.6 7.6 5.3 7 4 8 305 5.6 0 5.9 5.4 07/04/2005 01:10:00 6.8 0.4 7.6 5.7 6.9 0.3 7.6 5.7 4 3 3 305 5.4 0 5.6 5.4 07/04/2005 01:20:00 7 0.6 8.4 5.7 7 0.6 8.4 5.7 7 3 8 305 5.5 0 5.6 5.4 07/04/2005 01:30:00 6.8 0.4 8.4 5.7 6.5 0.5 7.6 5.3 16 6 18 305 5.5 0 5.6 5.4 07/04/2005 01:40:00 6.4 0.6 8 5.3 6.3 0.5 8 4.9 17 5 21 305 5.4 0 5.4 5.4 07/04/2005 01:50:00 7.8 0.7 9.5 5.7 7.6 0.8 9.5 5.3 14 3 21 305 5.5 0.1 5.9 5.4 07/04/2005 02:00:00 8.7 0.6 10.3 7.6 8.7 0.5 9.9 7.6 13 3 5 305 6.1 0.1 6.4 5.6 07/04/2005 02:10:00 8.7 0.5 10.7 7.2 8.6 0.5 10.3 7.6 12 3 9 305 6.1 0.1 6.4 5.9 07/04/2005 02:20:00 9 0.6 10.7 7.2 9 0.6 10.7 7.6 8 3 10 305 6.3 0.1 6.4 5.9 07/04/2005 02:30:00 8.6 0.8 10.7 7.2 8.5 0.7 10.7 7.2 9 4 11 305 6.1 0 6.4 5.9 07/04/2005 02:40:00 9.1 0.6 10.3 7.2 9 0.6 10.3 7.2 7 3 8 305 6.3 0 6.7 6.1 07/04/2005 02:50:00 10.1 0.8 12.2 8.4 10 0.8 12.2 8 5 4 10 305 6.6 0 6.9 6.1 07/04/2005 03:00:00 10.2 0.8 12.6 8.4 10.1 0.7 12.2 8.4 8 3 8 305 6.8 0.1 7.2 6.4 07/04/2005 03:10:00 9.9 0.6 11.1 8.4 9.7 0.7 11.8 8 9 4 8 305 6.5 0 6.9 6.4 07/04/2005 03:20:00 10 0.7 11.8 8.4 9.9 0.6 11.5 8.4 9 5 15 305 6.5 0 6.7 6.4 07/04/2005 03:30:00 8.6 0.5 10.3 7.2 8.7 0.6 10.3 7.2 6 3 4 305 6.3 0 6.7 6.1 07/04/2005 03:40:00 7.3 0.5 8.8 6.1 7.4 0.5 8.8 6.1 3 6 9 305 6.2 0 6.4 5.9 07/04/2005 03:50:00 8.3 0.6 9.5 6.8 8.2 0.7 9.5 6.5 359 3 1 305 6 0 6.1 5.9 07/04/2005 04:00:00 9 0.6 10.3 7.6 9 0.6 10.3 7.2 358 3 356 305 6 0 6.1 5.9 07/04/2005 04:10:00 8.9 0.5 10.3 7.6 9 0.5 10.3 7.6 357 3 0 305 6 0 6.1 5.9 07/04/2005 04:20:00 8.1 0.5 9.5 6.5 8.1 0.5 9.5 6.8 355 3 358 305 5.9 0 6.1 5.6 07/04/2005 04:30:00 8 0.4 9.1 6.8 8 0.4 9.1 6.5 1 3 359 305 5.8 0 5.9 5.9 07/04/2005 04:40:00 9.5 1 11.5 6.8 9.5 1 11.8 6.8 4 3 358 305 6.1 0.1 6.4 5.9 07/04/2005 04:50:00 9.5 1 11.8 7.6 9.6 1 11.8 7.2 5 3 9 305 6.2 0 6.4 6.1 07/04/2005 05:00:00 8.4 1 11.8 6.5 8.5 1 11.1 6.5 9 4 356 305 6.2 0 6.4 5.9 07/04/2005 05:10:00 9.5 0.8 12.6 7.2 9.5 0.8 12.2 7.6 8 4 10 305 6.1 0.1 6.4 5.9 07/04/2005 05:20:00 11.3 0.7 13 9.5 11.3 0.7 13.3 9.1 9 3 10 305 6 0 6.1 5.9 07/04/2005 05:30:00 10.8 0.6 13 8.8 10.8 0.8 13 9.1 10 4 8 305 6 0 6.1 5.9 07/04/2005 05:40:00 11.9 0.9 14.5 9.9 11.9 0.9 14.5 9.1 10 3 11 305 6.1 0 6.1 5.9 07/04/2005 05:50:00 11.7 0.7 13 9.5 11.7 0.8 13.3 8.8 13 3 11 305 6.1 0 6.1 5.9 07/04/2005 06:00:00 11.5 0.6 13.3 9.9 11.4 0.7 13.7 9.5 12 3 14 305 6 0 6.1 5.9 07/04/2005 06:10:00 11.6 0.7 13.7 9.5 11.5 0.8 13.7 9.5 12 3 17 305 6.1 0 6.1 5.9 07/04/2005 06:20:00 11.5 1 13.7 9.1 11.3 1.1 13.7 8.4 13 4 12 305 6 0 6.1 5.9 07/04/2005 06:30:00 11.5 0.8 14.1 9.5 11.5 0.8 13.7 9.1 13 4 12 305 6.1 0 6.1 5.9 07/04/2005 06:40:00 11.3 0.7 13.3 9.1 11.1 0.8 13.7 8.8 14 4 19 305 6 0 6.1 5.9 07/04/2005 06:50:00 11.3 0.9 13.3 9.1 11.1 0.9 13.3 8.4 18 5 13 305 6.1 0 6.4 5.9 07/04/2005 07:00:00 10.2 0.7 11.8 8 9.9 0.8 12.2 7.6 19 3 19 305 6.1 0 6.4 6.1 07/04/2005 07:10:00 9.6 0.6 11.5 8 9.4 0.6 11.1 7.6 17 4 27 305 6.2 0 6.4 6.1 07/04/2005 07:20:00 8.7 0.7 10.7 7.2 8.6 0.6 10.3 6.8 13 3 17 305 6.3 0 6.4 6.1 07/04/2005 07:30:00 8.6 0.6 10.7 7.2 8.4 0.6 10.7 6.8 14 4 14 305 6.3 0 6.4 6.1 07/04/2005 07:40:00 8.9 1 11.8 7.2 8.7 1 12.2 6.8 15 3 12 305 6.4 0 6.4 6.1 07/04/2005 07:50:00 10.4 0.9 12.6 8.8 10.1 0.8 12.2 8.4 17 4 16 305 6.5 0 6.9 6.1 07/04/2005 08:00:00 10.8 1 13.7 8.4 10.6 1 13 8 19 3 22 305 6.5 0 6.7 6.4 07/04/2005 08:10:00 11.1 0.7 12.6 9.5 10.9 0.7 12.6 9.1 21 4 20 305 6.5 0 6.7 6.4 07/04/2005 08:20:00 10.5 0.6 12.2 8.8 10.2 0.6 11.8 8.4 22 4 23 305 6.5 0 6.7 6.4 07/04/2005 08:30:00 10.3 0.6 11.8 8.8 10.1 0.7 12.2 8.4 23 4 21 305 6.4 0 6.4 6.1 07/04/2005 08:40:00 11.5 0.7 13.7 9.9 11.3 0.7 13 9.5 24 3 21 305 6.3 0 6.4 6.1 07/04/2005 08:50:00 10.5 1 12.6 8.4 10.2 1.1 12.6 8 24 3 16 305 6.1 0 6.4 5.9 07/04/2005 09:00:00 9.5 0.7 11.5 8 9.3 0.6 11.5 7.6 29 5 20 305 6.1 0 6.4 5.9 07/04/2005 09:10:00 9.6 0.8 11.5 7.2 9.3 0.9 11.8 6.5 30 5 31 305 6.1 0 6.4 5.9 07/04/2005 09:20:00 11.8 0.8 13.3 9.5 11.6 0.9 13.7 9.1 24 4 29 305 6.1 0 6.4 5.9 07/04/2005 09:30:00 11.8 1 14.1 9.5 11.6 1 14.1 9.1 21 4 26 305 6 0 6.1 5.9 07/04/2005 09:40:00 11.2 0.8 13.3 8.8 11 0.8 13.3 8.4 23 4 18 305 6 0 6.1 5.9 07/04/2005 09:50:00 11.1 0.7 13 9.5 10.8 0.8 12.6 8.4 22 4 26 305 6 0 6.1 5.9 07/04/2005 10:00:00 11.7 0.7 13.3 9.5 11.5 0.9 13.7 9.1 24 4 22 305 6 0 6.1 5.9 07/04/2005 10:10:00 10 0.7 11.8 7.6 9.7 0.7 11.5 7.6 31 4 29 305 6 0 6.1 5.9 07/04/2005 10:20:00 9.3 0.9 11.5 7.6 9 0.9 11.5 6.8 31 5 24 305 6 0.1 6.4 5.6 07/04/2005 10:30:00 10.6 0.6 12.6 9.1 10.2 0.7 12.6 8 29 4 28 305 6.2 0 6.4 5.9 07/04/2005 10:40:00 9.7 0.8 11.8 7.6 9.3 0.8 11.1 6.8 34 4 32 305 6.2 0 6.4 5.9 07/04/2005 10:50:00 9.8 0.9 12.2 7.6 9.5 0.9 11.8 7.2 34 3 29 305 6.3 0 6.4 6.1 07/04/2005 11:00:00 9.2 0.6 11.1 8 9 0.5 10.3 7.6 32 3 36 305 6.3 0 6.4 6.1 07/04/2005 11:10:00 7.9 0.6 9.1 6.1 7.6 0.7 9.1 5.3 34 4 33 305 6.3 0 6.4 5.9 07/04/2005 11:20:00 7.7 0.7 9.5 5.7 7.4 0.7 9.1 5.7 38 5 37 305 6.5 0 6.7 6.1 07/04/2005 11:30:00 7.9 0.6 9.1 5.7 7.7 0.6 9.5 5.7 34 4 31 305 6.5 0 6.9 6.1 07/04/2005 11:40:00 8 0.6 9.5 6.5 7.8 0.7 9.1 6.1 34 4 27 305 6.7 0.1 7.2 6.4 07/04/2005 11:50:00 8.4 0.9 10.7 6.5 8.1 0.9 10.3 6.1 33 5 27 305 6.7 0 6.9 6.4 07/04/2005 12:00:00 9.7 0.7 11.5 8 9.7 0.8 11.5 7.2 25 3 23 305 6.7 0 6.9 6.4 07/04/2005 12:10:00 10.2 0.6 11.8 8.4 10 0.7 11.8 7.6 28 4 36 305 6.6 0 6.9 6.4 07/04/2005 12:20:00 10 0.7 11.8 8.4 9.8 0.7 11.5 8.4 34 3 35 305 6.8 0.1 7.4 6.7 07/04/2005 12:30:00 10.4 0.6 11.8 8.4 10.3 0.7 12.2 8 32 3 35 305 6.8 0 7.2 6.7 07/04/2005 12:40:00 10.1 0.8 12.2 8.4 9.9 0.8 11.8 8 31 3 30 305 6.8 0 7.2 6.4 07/04/2005 12:50:00 9.9 0.5 11.5 8.4 9.8 0.6 11.1 7.6 35 3 29 305 6.8 0 7.2 6.4 07/04/2005 13:00:00 9.4 0.6 11.1 7.6 9.3 0.7 11.5 7.2 34 3 34 305 7 0 7.4 6.9 07/04/2005 13:10:00 10.1 0.7 11.5 8 10 0.8 11.5 7.6 37 4 39 305 7 0 7.4 6.9 07/04/2005 13:20:00 10.1 0.6 11.5 8.4 10 0.6 11.5 8.4 34 4 37 305 6.9 0 7.2 6.7 07/04/2005 13:30:00 9.2 0.6 10.7 7.6 9.1 0.7 10.7 6.8 34 4 32 305 7.1 0 7.4 6.9 07/04/2005 13:40:00 7.9 0.8 9.5 5.7 7.7 0.9 9.5 5.7 41 6 35 305 7.2 0.1 7.7 6.9 07/04/2005 13:50:00 8.2 0.5 9.5 6.8 8.2 0.5 9.1 6.8 40 3 40 305 7 0.1 7.4 6.7 07/04/2005 14:00:00 9.3 0.5 10.3 8 9.3 0.6 10.7 7.2 41 4 46 305 7 0 7.4 6.9 07/04/2005 14:10:00 8.9 0.6 10.3 6.8 8.7 0.7 9.9 6.5 44 4 41 305 7.2 0.1 7.4 6.9 07/04/2005 14:20:00 8.2 0.6 9.9 6.5 8.1 0.8 9.9 6.5 55 6 51 305 7 0 7.2 6.9 07/04/2005 14:30:00 8.4 0.7 9.9 6.5 8.2 0.7 9.5 6.5 50 6 49 305 7 0 7.4 6.9 07/04/2005 14:40:00 9.3 0.5 10.7 8 9.2 0.6 10.7 7.6 48 5 53 305 7 0 7.4 6.9 07/04/2005 14:50:00 8.8 0.7 10.3 6.5 8.7 0.8 10.7 6.1 51 5 46 305 6.9 0 7.2 6.7 07/04/2005 15:00:00 7.4 0.8 9.1 5.3 7.4 1 9.5 4.9 50 6 44 305 6.8 0.1 7.2 6.4 07/04/2005 15:10:00 7.3 0.7 9.1 5.3 7.2 0.7 9.1 5.7 58 5 62 305 7.1 0.1 7.7 6.9 07/04/2005 15:20:00 8.3 0.5 9.5 6.5 8.1 0.6 9.5 6.1 58 5 62 305 7.1 0.1 7.7 6.9 07/04/2005 15:30:00 8.3 0.6 9.5 6.8 8.2 0.6 9.5 6.5 51 5 57 305 6.9 0 7.4 6.7 07/04/2005 15:40:00 7.4 0.4 8.4 6.1 7.2 0.5 8.4 6.1 59 7 52 305 6.7 0 7.2 6.4 07/04/2005 15:50:00 8.3 0.6 9.5 6.5 8.2 0.6 9.5 6.5 61 5 56 305 6.8 0 7.2 6.4 07/04/2005 16:00:00 9.1 0.5 9.9 7.6 9 0.5 10.3 7.2 54 4 59 305 6.8 0.2 7.4 6.4 07/04/2005 16:10:00 8.6 0.5 9.9 6.8 8.5 0.6 9.9 6.8 54 5 53 305 6.9 0.2 7.4 6.4 07/04/2005 16:20:00 8.9 0.6 10.3 6.8 8.7 0.6 9.9 6.8 50 4 54 305 7 0 7.4 6.9 07/04/2005 16:30:00 9 0.4 9.9 7.6 8.8 0.5 9.9 7.2 50 4 40 305 6.9 0.1 7.4 6.7 07/04/2005 16:40:00 8.9 0.5 9.9 7.2 8.8 0.6 10.3 7.2 54 4 50 305 6.7 0 7.2 6.4 07/04/2005 16:50:00 8 0.6 9.1 6.5 8 0.6 9.1 5.7 54 5 57 305 6.9 0 7.2 6.7 07/04/2005 17:00:00 7.9 0.4 8.8 6.5 7.9 0.5 8.8 6.1 45 5 38 305 6.8 0 7.2 6.7 07/04/2005 17:10:00 7.5 0.4 8.8 6.5 7.5 0.4 8.8 6.1 48 4 49 305 6.8 0 7.7 6.7 07/04/2005 17:20:00 7.8 0.5 8.8 6.5 7.7 0.6 8.8 6.5 48 4 45 305 7 0 7.7 6.7 07/04/2005 17:30:00 7.8 0.5 8.8 6.1 7.7 0.6 8.8 6.1 48 4 46 305 7.2 0.1 7.7 6.9 07/04/2005 17:40:00 7.4 0.5 8.4 6.1 7.2 0.6 8.8 5.3 57 6 53 305 7.2 0.1 7.7 6.9 07/04/2005 17:50:00 7.7 0.5 9.5 6.1 7.6 0.6 9.5 6.1 57 7 74 305 7.2 0.1 7.7 7.2 07/04/2005 18:00:00 8 0.5 9.1 6.5 7.9 0.5 9.1 6.1 58 4 56 305 7 0 7.7 6.9 07/04/2005 18:10:00 8 0.4 8.8 6.5 8 0.4 8.8 6.5 51 4 53 305 7 0.1 7.7 6.9 07/04/2005 18:20:00 8.1 0.5 9.5 6.5 7.9 0.6 9.5 6.1 55 4 58 305 7.2 0.1 7.7 6.9 07/04/2005 18:30:00 8.7 0.4 9.5 6.8 8.5 0.5 9.5 6.8 56 3 58 305 7 0 7.4 6.9 07/04/2005 18:40:00 8.1 0.5 9.1 6.5 7.9 0.6 8.8 6.1 52 6 60 305 7.2 0.1 7.7 6.9 07/04/2005 18:50:00 8.7 0.6 10.3 7.2 8.5 0.7 10.3 6.5 52 6 57 305 7 0 7.4 6.9 07/04/2005 19:00:00 7 0.7 8.4 5.3 6.7 0.7 8 4.9 34 6 37 305 6.8 0.1 7.2 6.4 07/04/2005 19:10:00 7 0.3 7.6 6.1 6.9 0.5 8 5.3 36 4 30 305 6.7 0.1 7.2 6.4 07/04/2005 19:20:00 6 0.4 7.2 4.6 5.8 0.6 7.2 4.2 39 4 43 305 6.8 0.1 7.2 6.4 07/04/2005 19:30:00 6.6 0.6 7.6 4.9 6.4 0.7 7.6 4.2 42 4 41 305 6.7 0.1 7.2 6.4 07/04/2005 19:40:00 6.9 0.4 7.6 5.7 6.8 0.5 7.6 4.9 46 2 48 305 6.5 0 6.9 6.1 07/04/2005 19:50:00 5.4 0.5 6.8 4.6 5.1 0.6 6.5 3.8 41 5 46 305 6.3 0 6.4 6.1 07/04/2005 20:00:00 6.5 0.8 8 4.9 6.4 0.8 8 4.6 38 5 35 305 6.3 0 6.4 6.1 07/04/2005 20:10:00 6.8 0.7 8 4.9 6.7 0.8 8 4.6 32 2 33 305 6.3 0 6.4 6.1 07/04/2005 20:20:00 4.6 0.6 6.1 3.4 4.2 0.6 5.7 3 27 6 33 305 6.1 0 6.4 5.9 07/04/2005 20:30:00 5.8 0.6 6.8 4.2 5.7 0.6 6.8 4.2 19 3 16 305 5.9 0 6.1 5.6 07/04/2005 20:40:00 4.9 1 6.8 3 5 1.1 7.2 2.6 38 8 25 305 5.9 0 6.1 5.6 07/04/2005 20:50:00 5.4 1 6.8 3.4 5.3 0.9 6.5 3.4 29 6 22 305 5.9 0 5.9 5.6 07/04/2005 21:00:00 6.1 0.4 6.8 4.9 6 0.5 6.8 3.8 29 6 23 305 5.9 0 5.9 5.6 07/04/2005 21:10:00 5.5 0.4 6.5 4.6 5.3 0.5 6.5 3.8 43 5 41 305 5.5 0 5.9 5.4 07/04/2005 21:20:00 5.6 0.5 6.8 4.2 5.4 0.6 6.8 3.8 44 4 40 305 5.4 0 5.6 5.4 07/04/2005 21:30:00 4.5 0.6 5.7 3 4.2 0.5 5.3 3 49 6 44 305 5.4 0 5.6 5.4 07/04/2005 21:40:00 5.1 0.6 6.5 3.4 5.1 0.7 6.5 3.4 40 5 34 305 5.5 0 5.6 5.4 07/04/2005 21:50:00 4.7 0.6 5.7 3 4.4 0.6 5.7 2.6 39 4 35 305 5.2 0 5.4 4.9 07/04/2005 22:00:00 5.4 0.4 6.1 3.8 5.3 0.5 6.1 3.8 39 6 40 305 5.1 0 5.4 4.9 07/04/2005 22:10:00 4.8 0.5 5.7 3.8 4.7 0.5 5.7 3.8 52 6 52 305 5.1 0 5.4 4.9 07/04/2005 22:20:00 4.8 0.4 5.7 3.8 4.7 0.5 5.7 3 39 5 44 305 5 0.1 5.4 4.9 07/04/2005 22:30:00 4.3 0.3 4.9 3.4 4.2 0.3 4.6 3.4 46 9 31 305 4.8 0 5.2 4.7 07/04/2005 22:40:00 4.5 0.7 6.5 3 4.5 0.8 6.5 3 40 7 36 305 4.8 0 4.9 4.9 07/04/2005 22:50:00 5.4 0.4 6.5 4.2 5.3 0.4 6.5 4.2 32 5 27 305 4.8 0 5.2 4.7 07/04/2005 23:00:00 4.7 0.4 5.7 3.8 4.5 0.4 5.3 3.8 35 4 35 305 4.7 0.1 5.2 4.4 07/04/2005 23:10:00 5.5 0.3 6.1 4.6 5.3 0.4 6.1 4.2 39 5 48 305 4.7 0 4.9 4.4 07/04/2005 23:20:00 3.6 0.5 5.3 2.6 3.2 0.7 4.9 1.9 40 6 32 305 4.5 0 4.7 4.4 07/04/2005 23:30:00 5.2 0.3 6.1 4.6 5.1 0.4 6.1 4.2 29 3 30 305 4.4 0 4.7 4.4 07/04/2005 23:40:00 4.1 0.4 4.9 3 4 0.3 4.9 2.6 30 7 35 305 4.5 0 4.7 4.4 07/04/2005 23:50:00 5.3 0.4 6.1 3.8 5.3 0.4 6.1 4.2 25 5 21 305 4.6 0 4.9 4.4 07/05/2005 00:00:00 4.5 0.5 6.1 3.4 4.4 0.5 5.7 3.4 30 4 30 305 4.7 0 5.2 4.4 07/05/2005 00:10:00 5.3 0.3 6.1 4.6 5.4 0.3 6.1 4.6 31 5 29 305 4.6 0 4.7 4.4 07/05/2005 00:20:00 5.6 0.4 7.2 4.9 5.6 0.5 6.8 4.9 28 6 20 305 4.5 0 4.7 4.4 07/05/2005 00:30:00 6 0.3 6.8 4.9 6.1 0.3 7.2 5.3 35 4 40 305 4.4 0 4.7 4.4 07/05/2005 00:40:00 6 0.3 7.2 5.3 6.1 0.3 6.8 5.3 39 3 38 305 4.2 0 4.4 4.2 07/05/2005 00:50:00 5.8 0.4 7.2 4.9 5.9 0.4 7.2 4.9 38 5 39 305 4.2 0 4.4 4.2 07/05/2005 01:00:00 5.5 0.3 6.1 4.6 5.5 0.4 6.1 4.6 37 3 35 305 4 0 4.2 3.9 07/05/2005 01:10:00 6 0.5 6.8 4.9 6.1 0.5 7.2 4.9 36 5 38 305 4 0 4.2 3.7 07/05/2005 01:20:00 5.5 0.4 6.5 4.6 5.4 0.5 6.5 4.2 39 5 31 305 3.9 0 4.2 3.7 07/05/2005 01:30:00 5 0.5 6.1 3.8 4.9 0.6 6.5 3.8 38 9 38 305 3.9 0 4.2 3.7 07/05/2005 01:40:00 5.6 0.7 7.2 4.2 5.7 0.7 7.6 4.2 33 8 29 305 3.9 0 4.2 3.7 07/05/2005 01:50:00 6.1 0.5 6.8 4.9 6.1 0.5 7.2 4.9 32 5 35 305 4 0 4.2 3.9 07/05/2005 02:00:00 5.2 0.5 6.5 4.2 5.3 0.5 6.5 3.8 36 5 39 305 4.1 0 4.4 3.9 07/05/2005 02:10:00 4.8 0.4 6.5 3.8 4.9 0.4 6.1 3.8 32 6 33 305 4.1 0 4.4 3.9 07/05/2005 02:20:00 5.3 0.5 6.5 4.2 5.3 0.5 6.5 4.2 34 4 37 305 4 0 4.4 3.9 07/05/2005 02:30:00 4.7 0.3 5.7 3.8 4.8 0.3 5.3 4.2 36 5 30 305 4 0 4.4 3.9 07/05/2005 02:40:00 6 0.4 6.8 5.3 6 0.4 6.8 5.3 36 5 24 305 4 0 4.4 3.9 07/05/2005 02:50:00 5.9 0.5 7.6 4.9 5.9 0.6 7.6 4.6 35 5 36 305 4.1 0 4.4 3.9 07/05/2005 03:00:00 5.7 0.6 7.2 4.6 5.7 0.6 7.2 4.9 29 3 26 305 4.1 0 4.4 3.9 07/05/2005 03:10:00 5.8 0.5 6.8 4.6 5.9 0.5 6.8 4.9 29 5 25 305 4.1 0 4.4 3.9 07/05/2005 03:20:00 5.6 0.4 6.5 4.6 5.8 0.4 6.5 4.6 30 5 37 305 4.2 0 4.4 4.2 07/05/2005 03:30:00 5.9 0.5 6.8 4.9 6 0.5 7.2 4.6 34 4 32 305 4.2 0 4.4 4.2 07/05/2005 03:40:00 5 0.7 6.5 3.8 5.1 0.7 6.5 3.8 28 4 33 305 4.2 0 4.4 4.2 07/05/2005 03:50:00 4.3 0.4 4.9 3.4 4.4 0.4 4.9 3.4 30 5 31 305 4.2 0 4.4 4.2 07/05/2005 04:00:00 5.6 0.6 6.8 4.2 5.6 0.6 6.8 4.2 32 5 27 305 4.2 0 4.4 4.2 07/05/2005 04:10:00 5.7 0.4 6.5 4.6 5.9 0.5 6.8 4.6 31 4 33 305 4.1 0 4.4 3.9 07/05/2005 04:20:00 5.1 0.5 6.5 4.2 5.2 0.4 6.1 4.2 30 4 30 305 4.2 0 4.4 4.2 07/05/2005 04:30:00 5.4 0.4 6.5 4.6 5.4 0.4 6.5 4.2 29 3 29 305 4.2 0 4.4 4.2 07/05/2005 04:40:00 5.1 0.4 5.7 4.2 5.3 0.4 6.1 4.2 18 5 18 305 4.4 0 4.7 4.2 07/05/2005 04:50:00 5.3 0.5 6.1 3.8 5.5 0.5 6.1 4.2 21 6 30 305 4.2 0 4.4 4.2 07/05/2005 05:00:00 4.9 0.5 5.7 3.8 5 0.4 6.1 4.2 19 4 21 305 4.2 0 4.4 4.2 07/05/2005 05:10:00 5.2 0.4 6.5 4.2 5.3 0.4 6.5 4.6 26 4 27 305 4.1 0 4.4 3.9 07/05/2005 05:20:00 4.9 0.7 6.1 3.8 5.1 0.7 6.5 3.8 22 6 12 305 4 0.1 4.4 3.7 07/05/2005 05:30:00 5.6 0.4 6.5 4.6 5.7 0.4 6.8 4.6 29 3 32 305 4.1 0 4.4 3.9 07/05/2005 05:40:00 5.3 0.4 6.1 4.6 5.4 0.4 6.5 4.6 27 7 25 305 4.1 0 4.4 3.9 07/05/2005 05:50:00 5.7 0.3 6.8 4.9 5.8 0.3 6.8 4.9 25 3 23 305 4.2 0 4.4 3.9 07/05/2005 06:00:00 5.7 0.5 6.8 4.6 5.9 0.5 6.8 4.9 23 4 15 305 4.2 0 4.7 4.2 07/05/2005 06:10:00 5.1 0.4 6.1 4.6 5.3 0.3 6.1 4.6 26 7 38 305 4.2 0 4.7 4.2 07/05/2005 06:20:00 5.1 0.4 6.1 4.2 5.3 0.4 6.1 3.8 29 4 33 305 4.2 0 4.7 4.2 07/05/2005 06:30:00 5.3 0.5 6.5 4.6 5.4 0.5 6.5 4.2 27 3 27 305 4.3 0 4.7 4.2 07/05/2005 06:40:00 5 0.5 6.1 3.8 5.1 0.5 6.1 4.2 29 6 34 305 4.4 0 4.7 4.2 07/05/2005 06:50:00 5.1 0.3 6.1 4.2 5.3 0.3 6.1 4.2 29 7 22 305 4.4 0 4.9 4.2 07/05/2005 07:00:00 5.2 0.4 6.1 4.2 5.2 0.4 6.1 4.2 37 5 40 305 4.4 0 4.7 4.4 07/05/2005 07:10:00 4.8 0.3 5.7 4.2 4.8 0.4 5.7 3.8 34 3 33 305 4.4 0 4.9 4.2 07/05/2005 07:20:00 5.5 0.4 6.8 4.6 5.6 0.4 7.2 4.6 29 4 27 305 4.5 0.1 4.9 4.2 07/05/2005 07:30:00 5 0.6 6.5 3.4 5 0.6 6.5 3.8 28 4 33 305 4.7 0 4.9 4.4 07/05/2005 07:40:00 4.7 0.3 5.7 4.2 4.8 0.4 5.7 3.8 27 6 23 305 4.7 0 4.9 4.4 07/05/2005 07:50:00 4.3 0.6 5.7 2.6 4.3 0.6 5.7 3 34 6 34 305 4.8 0 5.4 4.7 07/05/2005 08:00:00 3.7 0.4 4.9 2.6 3.8 0.4 4.6 2.6 26 10 23 305 4.8 0.1 5.2 4.4 07/05/2005 08:10:00 3.8 0.6 4.9 2.6 3.8 0.6 4.9 2.6 34 5 29 305 4.6 0 4.9 4.4 07/05/2005 08:20:00 3.8 0.6 5.3 2.6 4 0.6 5.7 3 34 6 22 305 4.9 0 5.2 4.7 07/05/2005 08:30:00 3.9 0.5 4.9 3 3.9 0.5 4.9 3 44 6 46 305 5 0 5.4 4.9 07/05/2005 08:40:00 3.7 0.3 4.6 3 3.8 0.3 4.6 3 47 7 34 305 4.8 0 5.2 4.9 07/05/2005 08:50:00 4 0.3 4.6 3.4 4.1 0.3 4.6 3.4 41 4 50 305 4.9 0 5.4 4.7 07/05/2005 09:00:00 4.4 0.4 5.3 3.8 4.5 0.4 5.3 3.4 34 4 33 305 5 0 5.4 4.9 07/05/2005 09:10:00 4.2 0.4 5.3 3.4 4.4 0.4 5.3 3.4 36 4 41 305 5.1 0 5.4 4.9 07/05/2005 09:20:00 4.7 0.3 5.3 3.8 4.7 0.4 5.3 3 37 5 39 305 5 0 5.4 4.9 07/05/2005 09:30:00 4.1 0.4 4.9 3 4.2 0.4 5.3 3.4 37 5 42 305 5 0 5.4 4.9 07/05/2005 09:40:00 4.5 0.3 5.3 3.8 4.6 0.3 5.3 3.8 40 4 42 305 5.2 0.1 5.4 4.9 07/05/2005 09:50:00 3.8 0.4 4.6 2.6 3.9 0.4 4.9 3 41 5 44 305 5.4 0 5.6 5.2 07/05/2005 10:00:00 3.2 0.5 4.2 1.9 3.3 0.4 4.2 2.3 49 6 44 305 5.4 0 5.6 5.2 07/05/2005 10:10:00 2.9 0.5 4.2 1.5 3.1 0.4 4.2 2.3 47 7 49 305 5.5 0 5.6 5.4 07/05/2005 10:20:00 2.7 0.6 4.2 1.1 2.9 0.5 4.2 1.5 42 8 49 305 5.8 0 5.9 5.4 07/05/2005 10:30:00 2.3 0.6 3.8 0.4 2.6 0.5 4.2 1.5 34 8 39 305 5.9 0 6.1 5.9 07/05/2005 10:40:00 2.3 0.6 3.8 0.7 2.6 0.5 3.8 1.5 36 8 42 305 6 0 6.1 5.9 07/05/2005 10:50:00 1.9 0.6 3 0.4 2.2 0.5 3.4 1.1 37 13 44 305 6.3 0.1 6.7 5.9 07/05/2005 11:00:00 1.5 0.7 3 0.4 1.8 0.5 3.4 0.4 25 17 26 305 6.7 0 6.9 6.4 07/05/2005 11:10:00 2.1 0.5 3 0.7 2.4 0.4 3.4 1.1 31 13 27 305 6.8 0 6.9 6.7 07/05/2005 11:20:00 2.7 0.4 4.2 1.5 2.8 0.4 3.8 1.9 42 13 36 305 7 0 7.2 6.9 07/05/2005 11:30:00 2.8 0.4 3.8 1.9 3 0.4 4.2 1.5 23 11 41 305 7 0 7.4 6.9 07/05/2005 11:40:00 2.6 0.4 3.8 1.1 2.7 0.4 3.4 1.5 24 9 22 305 7 0 7.2 6.9 07/05/2005 11:50:00 2 0.4 3 0.7 2.2 0.4 3.8 1.1 25 12 19 305 7 0.1 7.4 6.9 07/05/2005 12:00:00 1.8 0.6 3.4 0.4 2 0.5 3 0.4 27 18 59 305 7.4 0 7.9 7.2 07/05/2005 12:10:00 1.5 0.5 2.6 0.4 1.8 0.5 2.6 0.7 16 15 10 305 7.7 0 7.9 7.7 07/05/2005 12:20:00 1.7 0.5 3 0.4 1.9 0.5 3 0.7 7 19 23 305 7.9 0 8.2 7.7 07/05/2005 12:30:00 1.9 0.5 3 0.7 2.1 0.4 3.8 1.1 13 15 3 305 7.7 0 7.9 7.7 07/05/2005 12:40:00 2.5 0.5 3.8 1.1 2.7 0.5 3.8 1.5 354 10 350 305 7.8 0.1 7.9 7.7 07/05/2005 12:50:00 2.5 0.4 3.4 1.5 2.7 0.4 3.8 1.1 350 11 346 305 7.8 0 8.2 7.7 07/05/2005 13:00:00 2 0.5 3 0.4 2.3 0.5 3.8 1.1 350 16 0 305 8.1 0.2 8.4 7.7 07/05/2005 13:10:00 2.1 0.7 3.4 0.4 2.5 0.6 4.2 1.1 347 15 357 305 8.3 0 8.7 8.2 07/05/2005 13:20:00 2.4 0.4 3.4 1.1 2.6 0.4 3.8 1.9 340 11 340 305 8.2 0 8.4 8.2 07/05/2005 13:30:00 2.7 0.5 4.2 1.5 3 0.4 4.2 1.9 336 11 337 305 8.4 0 8.4 8.2 07/05/2005 13:40:00 2.5 0.8 4.2 0.4 2.7 0.6 4.2 1.1 337 15 336 305 8.6 0 8.9 8.4 07/05/2005 13:50:00 2 0.6 3.4 0.4 2.2 0.5 3.4 0.7 353 19 347 305 8.9 0.1 9.2 8.4 07/05/2005 14:00:00 1.8 0.6 3.4 0.4 1.9 0.7 3.4 0.4 4 24 350 305 9.3 0.1 10.2 9.2 07/05/2005 14:10:00 1.8 0.7 3.8 0.4 2.1 0.6 3.8 0.7 335 26 312 305 10.1 0.2 10.8 9.7 07/05/2005 14:20:00 3 0.6 4.6 1.5 3 0.6 4.9 1.5 312 13 320 305 10.6 0 10.8 10.2 07/05/2005 14:30:00 3.7 0.9 5.7 1.5 3.7 0.8 6.5 1.5 294 13 282 305 10.2 0.1 10.5 10 07/05/2005 14:40:00 3 0.6 4.6 1.9 2.8 0.6 4.2 1.5 280 13 285 305 10.3 0 10.5 10 07/05/2005 14:50:00 3.7 0.5 5.7 1.9 3.2 0.5 4.6 1.9 267 10 267 305 10 0.2 10.5 9.7 07/05/2005 15:00:00 3.6 0.6 4.9 1.9 3.4 0.6 4.6 1.5 257 13 245 305 9.9 0 10.2 9.7 07/05/2005 15:10:00 3.7 0.6 5.3 1.9 3.6 0.7 4.9 1.5 253 11 253 305 9.9 0 10.2 9.7 07/05/2005 15:20:00 4.2 0.6 5.7 2.3 3.9 0.6 5.3 2.3 260 10 264 305 9.8 0 10 9.5 07/05/2005 15:30:00 4 0.6 5.3 2.3 4 0.6 5.3 2.6 252 12 266 305 9.9 0.1 10.2 9.7 07/05/2005 15:40:00 3.9 0.6 5.3 2.6 3.8 0.5 5.3 2.6 249 11 241 305 10.1 0.1 10.5 9.7 07/05/2005 15:50:00 3.9 0.6 5.3 2.3 3.8 0.6 5.3 1.9 252 12 247 305 10.4 0.1 10.8 10 07/05/2005 16:00:00 3.7 0.5 5.3 2.3 3.5 0.6 4.9 2.3 249 15 262 305 10.4 0 10.8 10.2 07/05/2005 16:10:00 4.2 0.6 5.7 2.6 4.2 0.6 5.7 2.6 229 10 231 305 10.3 0 10.5 10 07/05/2005 16:20:00 4.2 0.7 6.1 2.3 4.2 0.6 5.3 2.3 227 9 234 305 10.5 0 10.8 10.2 07/05/2005 16:30:00 4.3 0.6 6.1 2.3 4.2 0.6 5.7 2.6 229 10 231 305 10.4 0.1 10.8 10.2 07/05/2005 16:40:00 4.2 0.6 5.7 2.6 4.1 0.6 5.7 2.6 226 11 239 305 10.3 0 10.5 10.2 07/05/2005 16:50:00 4.1 0.6 6.1 2.3 4.1 0.6 5.7 3 227 10 216 305 10.5 0 10.8 10.2 07/05/2005 17:00:00 4.2 0.6 5.7 2.3 4.1 0.5 6.1 2.6 225 10 227 305 10.5 0 10.8 10.2 07/05/2005 17:10:00 4.2 0.6 5.7 2.6 4.2 0.6 5.7 2.6 223 9 231 305 10.4 0 10.8 10.2 07/05/2005 17:20:00 4.2 0.5 5.7 3 4.2 0.5 5.3 2.6 221 11 217 305 10.6 0 11 10.5 07/05/2005 17:30:00 4.5 0.6 6.5 3 4.4 0.6 6.1 2.6 227 9 225 305 10.8 0 11 10.8 07/05/2005 17:40:00 4.5 0.5 5.7 3 4.5 0.6 5.7 2.6 219 10 225 305 10.8 0 11 10.5 07/05/2005 17:50:00 4.6 0.6 6.1 3 4.6 0.6 6.1 3 223 9 224 305 10.7 0 10.8 10.5 07/05/2005 18:00:00 4.5 0.6 6.1 2.6 4.3 0.5 5.7 3 220 10 234 305 10.6 0 11 10.5 07/05/2005 18:10:00 4.5 0.5 6.1 2.6 4.5 0.5 5.7 3 220 9 224 305 10.9 0 11 10.5 07/05/2005 18:20:00 4.8 0.6 6.1 3 4.8 0.6 6.5 2.6 219 8 230 305 11 0 11 10.8 07/05/2005 18:30:00 5 0.6 6.5 3.4 4.9 0.6 6.5 3.4 217 8 229 305 11 0.1 11.3 10.8 07/05/2005 18:40:00 5.1 0.6 6.8 3.4 4.9 0.6 6.5 3.4 218 8 219 305 10.8 0 11 10.5 07/05/2005 18:50:00 4.8 0.6 6.1 3.4 4.6 0.5 6.1 3 218 8 208 305 10.8 0 10.8 10.5 07/05/2005 19:00:00 5 0.6 6.5 3.4 4.9 0.6 6.1 3 215 8 222 305 10.6 0 10.8 10.5 07/05/2005 19:10:00 5.1 0.6 6.8 3 5.1 0.6 6.8 3.4 213 8 214 305 10.4 0.1 10.8 10.2 07/05/2005 19:20:00 5.3 0.6 6.8 3.4 5.1 0.6 6.8 3.8 212 9 224 305 10.2 0 10.2 10 07/05/2005 19:30:00 5.3 0.7 7.2 2.6 5.1 0.6 6.8 3.8 215 11 228 305 10.2 0 10.5 10 07/05/2005 19:40:00 5.4 0.6 6.8 3.8 5.3 0.6 6.5 3.4 210 9 220 305 10 0 10.2 10 07/05/2005 19:50:00 5.5 0.6 7.6 4.2 5.3 0.5 6.8 3.8 213 11 206 305 10 0 10.2 9.7 07/05/2005 20:00:00 5.9 0.5 7.2 4.2 5.6 0.6 7.2 3.8 212 11 196 305 10.1 0 10.2 10 07/05/2005 20:10:00 5.8 0.6 7.2 3.8 5.6 0.6 7.2 4.2 211 9 200 305 10.1 0.2 10.5 9.7 07/05/2005 20:20:00 5.9 0.7 8 3.8 5.7 0.7 8 3.4 210 8 208 305 9.8 0 10 9.7 07/05/2005 20:30:00 5.9 0.6 8.4 4.2 5.9 0.6 7.6 4.2 210 7 220 305 9.7 0 10 9.5 07/05/2005 20:40:00 6.2 0.6 7.6 4.2 6.1 0.6 7.6 4.2 207 8 208 305 9.6 0 9.7 9.5 07/05/2005 20:50:00 6 0.6 8 4.2 5.9 0.6 7.6 4.2 208 8 204 305 9.3 0 9.5 9.2 07/05/2005 21:00:00 6.3 0.6 8.8 4.6 6.3 0.6 8 4.6 203 8 194 305 9.1 0 9.2 8.9 07/05/2005 21:10:00 6.2 0.6 8 4.6 5.9 0.7 8 3.8 208 10 205 305 9.1 0 9.5 8.9 07/05/2005 21:20:00 6.4 0.5 7.6 5.3 6.3 0.5 7.6 4.9 210 7 208 305 9.1 0 9.2 8.9 07/05/2005 21:30:00 6.6 0.8 9.1 4.9 6.5 0.7 8.8 4.2 207 9 193 305 9 0 9.2 8.9 07/05/2005 21:40:00 6.9 0.7 9.1 4.6 6.7 0.6 8.4 4.9 206 9 199 305 8.9 0 9.2 8.9 07/05/2005 21:50:00 6.6 0.6 8.4 4.9 6.5 0.6 8 4.9 206 9 215 305 8.6 0 8.9 8.4 07/05/2005 22:00:00 6.9 0.7 8.8 4.6 6.7 0.6 8.8 4.9 206 8 217 305 8.3 0 8.4 8.2 07/05/2005 22:10:00 6.6 0.6 8 4.9 6.5 0.6 8 4.9 206 8 196 305 8.4 0 8.4 8.2 07/05/2005 22:20:00 6.8 0.7 8.8 4.6 6.7 0.7 8.4 4.6 210 8 215 305 8.4 0 8.4 8.2 07/05/2005 22:30:00 6.7 0.6 9.1 4.9 6.5 0.6 8.4 4.9 209 8 217 305 8.5 0 8.7 8.4 07/05/2005 22:40:00 6.8 0.7 9.1 4.9 6.6 0.7 8.8 4.6 210 8 214 305 8.4 0 8.4 8.2 07/05/2005 22:50:00 6.8 0.7 8.8 4.6 6.7 0.7 8.8 4.6 209 9 207 305 8.4 0 8.4 8.2 07/05/2005 23:00:00 6.8 0.6 8.8 4.9 6.7 0.6 8.8 4.9 209 7 210 305 8.4 0 8.4 8.2 07/05/2005 23:10:00 6.9 0.8 8.8 4.6 6.5 0.8 8.4 4.6 212 9 218 305 8.4 0 8.4 8.4 07/05/2005 23:20:00 7.2 0.9 9.9 5.3 6.9 0.9 9.5 4.9 214 10 208 305 8.4 0 8.4 8.2 07/05/2005 23:30:00 6.8 0.9 9.5 4.2 6.6 0.8 8.8 4.6 215 9 210 305 8.4 0 8.4 8.2 07/05/2005 23:40:00 6.8 0.9 9.5 4.2 6.6 0.9 9.1 4.2 214 10 213 305 8.2 0.1 8.4 8.2 07/05/2005 23:50:00 6.9 0.8 9.1 4.9 6.6 0.8 8.8 4.6 213 9 218 305 8 0 8.2 7.9 07/06/2005 00:00:00 7.2 0.8 9.1 5.3 7.1 0.9 9.1 4.9 212 9 220 305 8 0 8.7 7.7 07/06/2005 00:10:00 6.6 0.7 8.8 4.6 6.3 0.6 8.4 4.6 215 8 217 305 7.9 0 7.9 7.7 07/06/2005 00:20:00 6.5 0.8 8.4 4.9 6.3 0.7 8.4 4.6 215 9 221 305 7.9 0 8.2 7.7 07/06/2005 00:30:00 6.9 0.8 9.1 4.6 6.8 0.7 9.1 4.9 213 10 216 305 8 0 8.2 7.7 07/06/2005 00:40:00 6.6 0.7 8.4 4.9 6.3 0.6 8 4.6 217 7 218 305 7.9 0 7.9 7.7 07/06/2005 00:50:00 6.7 0.6 8.4 4.9 6.3 0.6 8 4.6 216 7 214 305 8 0 8.2 7.9 07/06/2005 01:00:00 6.9 0.6 8.4 4.9 6.2 0.6 7.6 4.6 227 6 221 305 8 0 8.2 7.9 07/06/2005 01:10:00 6.7 0.6 8 5.3 6 0.6 7.6 4.6 228 6 239 305 8.1 0 8.2 7.9 07/06/2005 01:20:00 7.8 1 9.5 4.9 6.9 0.9 8.8 4.6 234 7 236 305 8.2 0.1 8.4 7.9 07/06/2005 01:30:00 6.7 0.7 8.4 5.3 6.1 0.7 8 4.2 232 7 242 305 8.2 0 8.4 8.2 07/06/2005 01:40:00 6.8 0.7 8.8 4.9 6 0.7 8.4 4.2 229 6 241 305 8.1 0 8.4 8.2 07/06/2005 01:50:00 7.3 1 9.1 4.9 6.8 0.9 8.8 4.6 230 6 239 305 8.2 0 8.4 8.2 07/06/2005 02:00:00 7.4 0.6 8.8 5.3 6.6 0.6 8.4 4.9 229 5 236 305 8.3 0 8.4 8.2 07/06/2005 02:10:00 7.6 0.5 8.8 6.1 7.1 0.6 8.4 4.6 232 4 234 305 8.4 0 8.4 8.2 07/06/2005 02:20:00 6.5 0.5 7.6 4.9 5.9 0.5 7.2 4.6 229 5 231 305 8.3 0 8.4 8.2 07/06/2005 02:30:00 6.2 0.6 7.6 4.6 5.8 0.6 7.6 4.6 226 5 225 305 8.2 0 8.4 8.2 07/06/2005 02:40:00 6.1 0.7 7.6 4.2 5.5 0.7 7.2 3.8 227 7 240 305 8.2 0 8.4 8.2 07/06/2005 02:50:00 7.2 0.6 8.4 5.7 6.6 0.7 8 4.6 231 5 231 305 8.4 0 8.9 8.2 07/06/2005 03:00:00 6.7 0.5 8.8 5.3 6.2 0.5 7.6 4.6 225 6 227 305 8.4 0.1 8.9 8.2 07/06/2005 03:10:00 6.8 0.6 8.4 5.3 6.3 0.7 8 4.6 222 7 226 305 8.4 0 8.9 8.2 07/06/2005 03:20:00 6.9 0.6 8.4 4.9 6.5 0.6 8 5.3 221 5 220 305 8.4 0 8.9 8.2 07/06/2005 03:30:00 6.9 0.7 8.8 5.3 6.4 0.6 8.4 4.9 223 7 215 305 8.4 0.1 8.9 8.2 07/06/2005 03:40:00 6.6 0.5 8 4.9 6.3 0.6 7.6 4.6 221 5 223 305 8.4 0.1 8.9 8.2 07/06/2005 03:50:00 6.7 0.5 8.8 5.3 6.2 0.5 7.6 4.9 227 6 232 305 8.4 0 8.9 8.2 07/06/2005 04:00:00 7.1 0.6 8.8 4.9 6.6 0.7 8.8 4.9 228 5 229 305 8.4 0.1 8.9 8.2 07/06/2005 04:10:00 6.8 0.6 8.4 5.3 6.2 0.7 8.4 4.2 227 6 231 305 8.4 0.1 8.9 8.2 07/06/2005 04:20:00 6.9 0.5 8.4 5.3 6.2 0.6 8 4.9 230 5 231 305 8.4 0 8.9 8.2 07/06/2005 04:30:00 7.6 0.5 8.8 6.1 6.9 0.6 8.4 4.9 230 5 234 305 8.4 0.1 8.9 8.2 07/06/2005 04:40:00 6.9 0.7 8.8 5.3 6.3 0.7 8 4.6 229 5 229 305 8.5 0 8.9 8.4 07/06/2005 04:50:00 6.7 0.6 8.4 5.3 6.2 0.6 7.6 4.6 228 6 233 305 8.4 0 8.9 8.2 07/06/2005 05:00:00 6.5 0.6 7.6 4.9 6 0.6 7.6 4.2 229 5 231 305 8.4 0.1 8.9 8.2 07/06/2005 05:10:00 7 0.6 8.4 4.9 6.4 0.7 8 4.6 227 6 231 305 8.4 0 8.4 8.2 07/06/2005 05:20:00 6.9 0.6 8.4 5.3 6.4 0.6 8 4.6 225 6 231 305 8.4 0 8.4 8.2 07/06/2005 05:30:00 7.2 0.5 8.4 5.7 6.9 0.6 8.4 5.3 222 5 225 305 8.4 0 8.4 8.4 07/06/2005 05:40:00 7 0.6 8.4 5.3 6.7 0.6 8.4 5.3 221 5 222 305 8.4 0 8.4 8.4 07/06/2005 05:50:00 7.6 0.6 8.8 5.7 7.1 0.6 8.8 5.3 222 5 231 305 8.4 0 8.7 8.2 07/06/2005 06:00:00 7.5 0.6 8.8 5.7 7.1 0.5 8.4 5.7 221 5 221 305 8.6 0 8.7 8.4 07/06/2005 06:10:00 7.5 0.7 9.1 5.7 7.1 0.8 8.8 4.9 217 6 218 305 8.6 0 8.7 8.4 07/06/2005 06:20:00 7.5 0.7 9.1 5.3 7 0.8 9.1 4.6 216 7 210 305 8.6 0 8.7 8.4 07/06/2005 06:30:00 8 0.6 9.5 6.5 7.3 0.8 9.1 5.7 224 5 226 305 8.7 0 8.9 8.4 07/06/2005 06:40:00 8.1 0.7 9.9 5.7 7.8 0.7 9.5 5.7 219 4 220 305 8.8 0 8.9 8.9 07/06/2005 06:50:00 7.8 0.6 9.5 6.1 7.3 0.7 8.8 5.3 216 5 220 305 8.9 0 9.2 8.9 07/06/2005 07:00:00 7.1 0.5 8.4 5.7 7 0.5 8.4 5.3 206 7 207 305 9.1 0 9.2 8.9 07/06/2005 07:10:00 6.8 0.7 8.4 4.6 6.4 0.7 8 4.2 220 8 222 305 9.1 0 9.2 8.9 07/06/2005 07:20:00 6.9 0.7 8.4 4.9 6.4 0.7 8.4 4.9 218 7 224 305 9 0 9.5 8.9 07/06/2005 07:30:00 7.6 0.7 9.1 5.7 6.9 0.7 8.8 4.9 236 8 238 305 8.8 0.1 9.5 8.9 07/06/2005 07:40:00 8.2 0.7 9.9 5.7 7.4 0.7 9.1 5.3 240 5 242 305 8.8 0 9.2 8.7 07/06/2005 07:50:00 7.6 0.9 9.5 5.3 6.9 0.9 9.1 4.9 231 7 242 305 8.8 0.1 9.2 8.7 07/06/2005 08:00:00 6.7 0.6 8.4 4.9 6.2 0.6 8 4.6 238 8 245 305 8.8 0 9.2 8.7 07/06/2005 08:10:00 6.9 0.6 8.8 5.3 6.3 0.6 8 4.6 239 7 239 305 8.9 0 9.2 8.7 07/06/2005 08:20:00 6.5 0.6 8 4.9 6 0.6 7.6 4.2 230 7 236 305 8.9 0 9.2 8.9 07/06/2005 08:30:00 6.9 0.6 8 4.9 6.5 0.7 8 4.2 232 7 235 305 8.9 0 9.5 8.9 07/06/2005 08:40:00 6.9 0.6 8.4 5.3 6.4 0.6 8 4.9 225 6 224 305 9.1 0 9.7 8.9 07/06/2005 08:50:00 7.1 0.7 8.8 4.9 6.6 0.7 8 4.6 226 6 224 305 9.4 0.1 10 9.2 07/06/2005 09:00:00 7 0.6 8.8 5.3 6.6 0.6 8 4.6 224 7 231 305 9.5 0 10 9.5 07/06/2005 09:10:00 6.9 0.7 8.4 4.9 6.3 0.7 8.4 4.6 227 7 229 305 9.3 0 9.7 9.2 07/06/2005 09:20:00 7 0.6 8.8 4.9 6.5 0.7 8 4.6 227 6 233 305 9.2 0 9.7 9.2 07/06/2005 09:30:00 7.3 0.7 8.8 5.3 7 0.7 8.8 5.3 230 5 229 305 9.2 0 9.7 9.2 07/06/2005 09:40:00 6.3 0.7 8 4.2 6.1 0.6 7.6 4.6 218 9 218 305 9.2 0 9.7 9.2 07/06/2005 09:50:00 7.1 0.9 9.5 4.2 6.8 0.9 9.1 4.9 228 9 225 305 9.3 0 9.5 9.2 07/06/2005 10:00:00 8.2 1 10.7 5.7 7.8 1 10.3 5.7 236 6 237 305 9.2 0 9.5 9.2 07/06/2005 10:10:00 8.8 1.1 10.7 5.7 8.2 1.1 10.7 5.3 229 6 229 305 9 0 9.5 8.9 07/06/2005 10:20:00 9 0.7 10.3 6.8 8.4 0.8 10.3 6.5 227 5 229 305 9 0 9.5 8.9 07/06/2005 10:30:00 8.5 1 10.3 5.7 8 1.1 10.3 5.3 226 6 223 305 8.9 0 9.5 8.9 07/06/2005 10:40:00 10 1 11.8 7.2 9.3 1.1 11.5 6.5 229 6 235 305 8.8 0 9.5 8.4 07/06/2005 10:50:00 9.7 1 11.8 7.2 9.1 1 11.5 6.5 233 5 232 305 8.6 0 9.2 8.4 07/06/2005 11:00:00 9.8 1 11.5 7.2 9.1 1.1 11.5 6.1 238 6 239 305 8.4 0 8.9 8.2 07/06/2005 11:10:00 9.3 1.1 11.5 6.1 8.7 1.2 11.1 5.3 242 6 250 305 8.2 0 8.4 8.2 07/06/2005 11:20:00 8.8 0.8 10.7 6.8 8.2 0.9 10.3 5.7 233 6 238 305 8.4 0 8.4 8.2 07/06/2005 11:30:00 9.7 0.8 11.5 6.5 8.9 0.9 11.1 6.5 234 6 238 305 8.3 0 8.4 8.2 07/06/2005 11:40:00 8.7 0.9 10.7 6.5 8.1 0.9 10.3 5.7 234 6 238 305 8.4 0 8.4 8.2 07/06/2005 11:50:00 9.6 0.9 12.2 7.2 9 0.9 11.5 7.2 235 5 237 305 8.3 0 8.4 8.2 07/06/2005 12:00:00 10.4 0.8 12.2 8 9.7 0.9 11.8 7.2 232 5 235 305 8.4 0 8.4 8.2 07/06/2005 12:10:00 9 0.9 11.1 6.8 8.4 1 11.1 5.7 225 6 220 305 8.5 0 8.7 8.4 07/06/2005 12:20:00 9 0.9 10.7 6.5 8.4 0.9 10.3 6.5 225 6 230 305 8.6 0 8.7 8.4 07/06/2005 12:30:00 9.4 0.7 11.1 7.2 8.8 0.8 10.7 6.5 223 5 223 305 8.5 0 8.7 8.4 07/06/2005 12:40:00 9.9 0.9 11.8 7.2 9.2 0.9 11.5 6.8 224 5 231 305 8.5 0 8.7 8.4 07/06/2005 12:50:00 8.6 1.3 11.8 5.7 8 1.2 11.1 5.7 226 6 210 305 8.6 0 8.7 8.4 07/06/2005 13:00:00 8.6 1.2 11.1 5.7 8.2 1.1 10.7 5.7 224 6 222 305 8.4 0 8.7 8.2 07/06/2005 13:10:00 9.5 0.7 11.1 7.2 9 0.8 10.7 6.8 223 5 225 305 8.5 0 8.7 8.4 07/06/2005 13:20:00 9.5 0.9 11.5 7.2 8.9 1 11.5 6.5 226 6 228 305 8.6 0 8.9 8.4 07/06/2005 13:30:00 10.4 1.1 12.6 7.6 9.9 1.2 12.6 6.5 229 5 238 305 8.6 0 8.9 8.4 07/06/2005 13:40:00 9.5 0.8 11.1 7.2 9.1 0.9 11.5 6.8 231 5 227 305 8.7 0 9.2 8.4 07/06/2005 13:50:00 8.7 0.9 10.7 6.1 8.3 0.9 10.7 5.7 232 6 231 305 8.9 0 9.2 8.7 07/06/2005 14:00:00 10 0.9 11.8 6.8 9.4 1 11.8 7.2 227 5 227 305 8.9 0 9.5 8.9 07/06/2005 14:10:00 10.2 0.8 11.8 8.4 9.7 1 11.8 6.8 230 6 228 305 9.1 0 9.5 8.9 07/06/2005 14:20:00 9.2 0.9 11.5 7.2 8.6 1 11.1 6.1 226 5 225 305 9.1 0.1 9.2 8.9 07/06/2005 14:30:00 9.6 0.9 11.8 6.5 9.2 1 11.5 6.8 231 5 234 305 8.9 0.1 9.2 8.7 07/06/2005 14:40:00 10.3 0.9 12.2 7.6 9.6 1.1 12.2 6.5 237 6 234 305 8.8 0 9.5 8.7 07/06/2005 14:50:00 10.1 1.1 12.6 7.6 9.3 1.1 11.5 6.5 237 5 239 305 8.8 0 9.5 8.7 07/06/2005 15:00:00 10.5 0.9 12.2 7.6 9.9 1 11.8 6.5 243 5 245 305 8.8 0 9.2 8.7 07/06/2005 15:10:00 10.6 1.1 12.6 8.4 10 1.1 12.2 7.2 241 6 244 305 8.9 0 9.5 8.9 07/06/2005 15:20:00 9.7 1 11.8 6.8 9 1 11.5 6.5 237 5 240 305 9.1 0 9.5 8.9 07/06/2005 15:30:00 9.7 1.1 12.6 6.8 8.9 1.1 11.5 6.5 240 6 245 305 9.1 0 9.2 8.9 07/06/2005 15:40:00 9.9 1 12.2 7.2 9.3 1 11.5 6.5 237 5 236 305 9.1 0 9.7 8.9 07/06/2005 15:50:00 10.1 0.8 11.5 8 9.4 0.8 11.1 7.2 236 5 229 305 9 0 9.2 8.9 07/06/2005 16:00:00 9.3 0.9 11.1 6.8 8.7 1 11.1 6.1 233 5 237 305 9.1 0 9.2 8.9 07/06/2005 16:10:00 9.5 1.1 12.2 6.5 8.9 1.1 11.5 6.5 239 6 244 305 9.1 0 9.5 9.2 07/06/2005 16:20:00 9.4 1 11.8 6.8 9 1 11.8 6.8 235 5 233 305 9.1 0 9.5 8.9 07/06/2005 16:30:00 10.1 0.8 11.8 8 9.4 0.8 11.5 7.2 236 4 236 305 9.1 0 9.7 9.2 07/06/2005 16:40:00 8.9 0.9 11.1 6.5 8.4 1 10.7 6.1 231 6 239 305 9.2 0 9.7 9.2 07/06/2005 16:50:00 8.9 0.9 10.7 6.5 8.4 0.9 10.3 6.1 228 6 228 305 9.2 0 9.7 9.2 07/06/2005 17:00:00 9.4 1.2 11.8 6.8 8.9 1.2 11.5 6.1 227 6 229 305 9.3 0.1 10 9.2 07/06/2005 17:10:00 9.7 1 11.5 7.2 9.1 1.1 11.5 6.1 225 5 224 305 9.4 0.1 10 9.2 07/06/2005 17:20:00 10.2 0.9 12.2 7.6 9.4 1 11.5 6.5 225 5 232 305 9.3 0.1 9.7 9.2 07/06/2005 17:30:00 10 0.7 12.2 7.6 9.3 1 11.5 6.5 226 5 225 305 9.3 0.1 9.7 9.2 07/06/2005 17:40:00 9.9 0.8 11.8 7.6 9.4 0.9 11.8 6.8 223 5 218 305 9.1 0 9.7 8.9 07/06/2005 17:50:00 10.3 1 12.6 7.2 9.6 1 12.2 6.8 225 6 228 305 9.1 0 9.5 8.9 07/06/2005 18:00:00 10.6 0.8 12.6 8.4 10 0.9 12.2 8 228 5 231 305 9.1 0 9.7 8.9 07/06/2005 18:10:00 9.7 1 12.2 7.2 9.2 1.1 11.8 6.5 230 5 234 305 8.9 0.1 9.5 8.7 07/06/2005 18:20:00 10.2 1 11.8 7.2 9.5 1 11.8 6.8 230 5 227 305 8.8 0 9.2 8.7 07/06/2005 18:30:00 10.6 1 12.6 7.6 10 1.1 12.2 7.2 229 6 229 305 8.7 0 8.9 8.4 07/06/2005 18:40:00 10.8 0.8 12.6 8 10.1 0.9 12.6 7.6 229 6 235 305 8.8 0 8.9 8.7 07/06/2005 18:50:00 10.3 1 12.6 7.2 9.6 1.1 12.6 6.8 227 5 228 305 8.8 0 8.9 8.4 07/06/2005 19:00:00 10.5 1 12.6 7.2 9.9 1.2 12.2 6.1 223 6 228 305 8.8 0 8.9 8.7 07/06/2005 19:10:00 11.4 1.2 13.7 8.4 10.8 1.3 13.7 7.6 226 6 230 305 8.7 0 8.9 8.4 07/06/2005 19:20:00 10.2 1.2 13 7.6 9.5 1.2 12.6 6.8 225 5 224 305 8.8 0 8.9 8.7 07/06/2005 19:30:00 11 1.1 13.3 8.4 10.2 1.2 13.3 7.2 227 6 229 305 8.8 0 8.9 8.7 07/06/2005 19:40:00 10.6 1 12.6 8.4 9.9 1 12.2 6.8 227 6 227 305 8.7 0 8.9 8.4 07/06/2005 19:50:00 11.3 1 13.7 8.8 10.7 1.1 13.3 7.2 223 6 218 305 8.6 0 8.9 8.4 07/06/2005 20:00:00 10.3 1.5 13.3 7.2 9.6 1.4 13 6.8 225 5 227 305 8.6 0 8.9 8.4 07/06/2005 20:10:00 10.2 1.2 13 7.2 9.5 1.1 12.6 6.8 228 5 228 305 8.6 0 8.9 8.4 07/06/2005 20:20:00 10.3 0.9 12.6 7.6 9.8 0.9 12.2 7.6 230 5 234 305 8.5 0 8.7 8.4 07/06/2005 20:30:00 10.9 0.9 13 8.4 10.3 0.9 12.2 7.6 229 5 227 305 8.6 0 8.7 8.4 07/06/2005 20:40:00 10.1 1.1 12.6 7.2 9.5 1.1 11.8 6.5 225 6 221 305 8.5 0 8.7 8.4 07/06/2005 20:50:00 10.8 0.8 13 8.8 10 0.8 12.2 8 223 5 224 305 8.4 0 8.7 8.2 07/06/2005 21:00:00 11.4 0.9 13 8.8 10.4 1 13 8 225 5 227 305 8.4 0 8.4 8.2 07/06/2005 21:10:00 10.6 1.1 13 7.2 9.9 1 12.2 7.2 224 5 230 305 8.4 0 8.4 8.2 07/06/2005 21:20:00 11.7 0.7 13.3 9.1 11 0.9 12.6 8 228 6 218 305 8.3 0 8.4 8.2 07/06/2005 21:30:00 10.5 0.9 12.2 7.6 9.8 1 11.8 7.2 226 6 228 305 8.3 0 8.4 8.2 07/06/2005 21:40:00 10.8 1 13.7 7.2 10.1 1.1 13 7.6 223 6 228 305 8.2 0 8.4 8.2 07/06/2005 21:50:00 11.3 0.9 13 9.1 10.4 1.1 13 7.6 228 6 231 305 8.2 0 8.2 8.2 07/06/2005 22:00:00 11.6 1 13.7 8.8 10.8 1.1 13.3 7.6 229 6 231 305 8.2 0 8.2 8.2 07/06/2005 22:10:00 11.8 0.8 13.7 8.8 11 1 13.3 7.6 229 5 228 305 8.2 0 8.2 8.2 07/06/2005 22:20:00 10.9 1 13 8 10.1 1 12.6 7.6 231 6 225 305 8.2 0 8.2 8.2 07/06/2005 22:30:00 10.8 0.8 12.6 8.8 9.9 1 12.2 7.2 226 5 226 305 8.2 0 8.4 8.2 07/06/2005 22:40:00 9.8 0.9 12.2 6.8 9.3 1 11.5 6.5 223 5 224 305 8.2 0 8.2 8.2 07/06/2005 22:50:00 10.8 1.1 13.3 7.2 10 1.1 12.6 7.2 223 5 228 305 8.1 0 8.2 8.2 07/06/2005 23:00:00 11 1 13 7.6 10.2 1 12.6 7.2 225 5 225 305 8.1 0 8.2 8.2 07/06/2005 23:10:00 10.2 1 13 8 9.5 1 11.8 7.2 225 5 217 305 8.1 0 8.2 8.2 07/06/2005 23:20:00 10.1 1.2 12.2 7.6 9.5 1.1 11.8 6.8 223 6 224 305 8.1 0 8.2 8.2 07/06/2005 23:30:00 9.6 0.8 12.2 7.6 9.1 0.8 11.1 6.5 220 5 219 305 8.1 0 8.2 7.9 07/06/2005 23:40:00 9.8 1.2 12.2 7.2 9.1 1.2 12.2 6.1 223 6 224 305 8.1 0 8.2 7.9 07/06/2005 23:50:00 10.8 1 12.6 8 10.2 1 12.6 7.6 221 6 227 305 8.1 0 8.2 7.9 07/07/2005 00:00:00 9.4 0.9 11.8 7.6 8.9 0.9 11.1 6.5 224 6 225 305 8 0 8.2 7.9 07/07/2005 00:10:00 9.4 0.9 11.8 6.5 8.8 1 11.5 6.1 225 5 224 305 8.1 0 8.2 7.9 07/07/2005 00:20:00 10.8 0.8 12.6 8 10.3 1 12.6 8 220 4 224 305 8 0 8.2 7.9 07/07/2005 00:30:00 10.7 1 13 7.6 10 1.1 12.2 6.8 222 6 234 305 8 0 8.2 7.9 07/07/2005 00:40:00 10.3 1.1 12.6 6.8 9.7 1.3 12.6 6.1 227 5 227 305 8 0 8.2 7.9 07/07/2005 00:50:00 10.2 1 13 8 9.4 1 12.6 6.8 222 6 219 305 8 0 8.2 7.9 07/07/2005 01:00:00 9.8 1 12.6 8 9.2 1.1 11.8 7.2 224 5 220 305 8 0 8.2 7.9 07/07/2005 01:10:00 10.6 1 13 6.8 9.9 1.1 12.6 7.2 223 6 218 305 8 0 8.2 7.9 07/07/2005 01:20:00 9.8 1.1 12.6 7.2 9.2 1.1 12.6 6.8 222 6 223 305 8 0 8.2 7.9 07/07/2005 01:30:00 10.8 0.9 13 8.4 10.1 1.1 12.6 7.2 226 5 224 305 8 0 8.2 7.9 07/07/2005 01:40:00 11 0.9 13 8 10.3 1 12.2 7.2 226 5 226 305 7.9 0 8.2 7.7 07/07/2005 01:50:00 9.6 1.1 11.8 6.8 9.1 1.1 11.5 6.5 222 6 218 305 8 0 8.2 7.9 07/07/2005 02:00:00 9.7 0.8 11.8 7.6 9.3 0.9 11.5 6.8 221 6 227 305 8 0 8.2 7.9 07/07/2005 02:10:00 10.4 1.1 13 6.8 9.7 1.2 12.6 6.5 225 5 224 305 7.9 0 8.2 7.7 07/07/2005 02:20:00 9.5 1.2 12.2 6.8 8.9 1.2 11.8 6.1 227 6 227 305 7.9 0 7.9 7.7 07/07/2005 02:30:00 11.6 1 13.7 8.4 10.8 1.2 13 7.2 226 4 229 305 7.9 0 7.9 7.7 07/07/2005 02:40:00 11.7 0.8 13.3 8.8 10.7 1 12.6 7.6 228 4 225 305 7.9 0 7.9 7.7 07/07/2005 02:50:00 11 0.9 12.6 8.4 10.3 1 12.2 7.6 228 5 228 305 7.9 0 7.9 7.7 07/07/2005 03:00:00 10.7 1.1 13.3 8 10.1 1.2 13.3 7.2 222 6 221 305 7.9 0 7.9 7.9 07/07/2005 03:10:00 10.5 0.9 12.6 7.6 10 1 12.2 6.8 218 5 218 305 7.9 0 7.9 7.7 07/07/2005 03:20:00 10.9 1 13.3 8 10.4 1.1 13.3 7.6 218 5 214 305 7.9 0 7.9 7.7 07/07/2005 03:30:00 11.2 0.9 13.3 8.4 10.5 1 12.6 8 223 5 226 305 7.8 0 7.9 7.7 07/07/2005 03:40:00 10.7 1 13 8 9.9 1.1 12.6 7.2 223 6 225 305 7.9 0 7.9 7.7 07/07/2005 03:50:00 10.6 0.8 12.2 8 9.9 1 11.8 6.8 221 6 218 305 7.9 0 7.9 7.7 07/07/2005 04:00:00 10.3 1.2 12.6 7.2 9.7 1.2 12.6 6.8 226 5 232 305 7.8 0 7.9 7.7 07/07/2005 04:10:00 10.2 1 12.2 7.2 9.4 1.2 11.5 6.5 227 6 224 305 7.8 0 7.9 7.7 07/07/2005 04:20:00 10.1 0.9 11.8 6.8 9.3 1 11.5 6.8 225 5 227 305 7.8 0 7.9 7.7 07/07/2005 04:30:00 10.4 0.6 11.8 8.4 9.9 0.7 11.8 8 218 5 220 305 7.8 0 7.9 7.7 07/07/2005 04:40:00 10.6 0.9 12.6 8 9.9 0.9 12.2 7.6 221 5 228 305 7.7 0 7.9 7.7 07/07/2005 04:50:00 9.4 1 11.8 7.2 8.9 1.1 11.8 6.1 222 5 220 305 7.8 0 7.9 7.7 07/07/2005 05:00:00 10.4 0.9 12.6 7.6 9.9 1 12.2 6.8 223 5 227 305 7.7 0 7.9 7.7 07/07/2005 05:10:00 11 0.9 12.6 8 10.2 0.9 12.2 7.2 222 5 224 305 7.8 0 7.9 7.7 07/07/2005 05:20:00 9.7 0.8 11.5 6.8 9.2 0.8 11.5 7.2 219 5 227 305 7.8 0 7.9 7.7 07/07/2005 05:30:00 10.1 1 12.2 7.2 9.5 1.1 11.8 6.5 223 5 229 305 7.7 0 7.9 7.7 07/07/2005 05:40:00 9.8 1 11.8 6.8 9.3 1 11.5 6.8 221 6 217 305 7.7 0 7.9 7.7 07/07/2005 05:50:00 10.3 1 12.2 7.6 9.6 1 11.8 7.2 224 5 224 305 7.7 0 7.9 7.7 07/07/2005 06:00:00 9.6 1 11.5 7.2 9.1 1 11.5 6.8 221 5 231 305 7.7 0 7.9 7.7 07/07/2005 06:10:00 9.6 0.8 11.8 7.2 9.1 1 11.1 6.8 222 5 218 305 7.7 0 7.9 7.7 07/07/2005 06:20:00 10.1 1 12.2 7.2 9.6 1 11.8 6.5 222 5 221 305 7.7 0 7.9 7.7 07/07/2005 06:30:00 10.3 0.6 11.8 8.4 9.8 0.8 11.5 7.6 216 5 221 305 7.7 0 7.9 7.7 07/07/2005 06:40:00 10.4 0.8 12.2 8 10.1 1 11.8 7.2 216 5 214 305 7.7 0 7.9 7.7 07/07/2005 06:50:00 11.3 0.7 13 9.1 10.9 0.9 13 8.4 217 4 217 305 7.7 0 7.9 7.7 07/07/2005 07:00:00 10.3 0.8 12.6 7.6 9.9 1 12.2 7.2 217 4 219 305 7.8 0 7.9 7.7 07/07/2005 07:10:00 10.7 0.7 12.2 8.4 10.2 0.8 11.8 8 218 4 222 305 7.8 0 7.9 7.7 07/07/2005 07:20:00 10.4 1 12.6 6.8 9.8 1.1 12.6 6.8 214 5 218 305 7.8 0 7.9 7.7 07/07/2005 07:30:00 10 0.9 11.8 7.2 9.6 1.1 11.8 6.5 217 5 217 305 7.9 0 7.9 7.7 07/07/2005 07:40:00 10.2 0.8 12.2 6.8 9.7 1 11.8 7.2 217 5 222 305 7.8 0 7.9 7.7 07/07/2005 07:50:00 10.7 0.7 12.6 8.8 10.2 0.8 12.2 7.6 216 4 211 305 7.8 0 7.9 7.7 07/07/2005 08:00:00 10.2 0.9 12.6 7.2 9.6 1 12.2 6.8 215 5 220 305 7.9 0 7.9 7.7 07/07/2005 08:10:00 10.5 0.8 12.6 7.6 9.9 1 12.2 7.2 213 5 214 305 7.9 0 8.2 7.7 07/07/2005 08:20:00 10.1 0.9 11.8 6.8 9.6 1 12.2 6.8 215 6 221 305 7.9 0 8.2 7.7 07/07/2005 08:30:00 10.5 1.2 13 7.2 10 1.3 12.2 6.5 214 5 213 305 7.9 0 8.2 7.7 07/07/2005 08:40:00 10.4 1 13 8 9.9 1.1 12.2 7.2 212 5 221 305 8 0 8.2 7.9 07/07/2005 08:50:00 11.4 0.8 14.1 9.5 10.7 0.9 13 7.6 214 4 207 305 7.9 0 8.2 7.7 07/07/2005 09:00:00 10.1 0.8 11.8 7.2 9.6 0.9 11.8 6.5 216 5 217 305 8 0 8.2 7.9 07/07/2005 09:10:00 10.6 1 12.6 7.2 9.9 1.1 12.2 6.5 216 5 213 305 8 0 8.2 7.9 07/07/2005 09:20:00 10.7 0.8 12.6 8 10.3 1 12.6 6.8 213 6 213 305 8 0 8.2 7.9 07/07/2005 09:30:00 9.7 1 12.2 6.5 9.1 1.1 11.8 6.5 213 6 224 305 8.1 0 8.2 7.9 07/07/2005 09:40:00 10.1 1 12.2 7.2 9.4 1.1 12.2 6.1 211 6 213 305 8.2 0 8.2 7.9 07/07/2005 09:50:00 9.7 0.8 11.8 7.2 9.2 0.9 11.8 6.8 213 5 218 305 8.2 0 8.2 8.2 07/07/2005 10:00:00 10 1 11.8 7.6 9.4 1 11.8 6.5 210 5 213 305 8.2 0 8.4 8.2 07/07/2005 10:10:00 10.1 1 12.6 7.6 9.7 1 11.8 6.8 211 5 210 305 8.2 0 8.4 8.2 07/07/2005 10:20:00 10.2 0.9 11.8 7.2 9.6 1.2 11.8 6.5 212 5 215 305 8.2 0 8.4 8.2 07/07/2005 10:30:00 9.5 1 11.5 6.8 9.1 1 11.5 6.5 210 5 215 305 8.4 0 8.7 8.2 07/07/2005 10:40:00 9.1 0.8 11.1 6.5 8.6 1 10.7 5.7 209 5 213 305 8.5 0 8.7 8.4 07/07/2005 10:50:00 9.7 0.6 11.1 7.6 9.4 0.8 11.1 6.8 206 5 211 305 8.5 0 8.9 8.2 07/07/2005 11:00:00 9.7 0.7 11.8 8 9.6 0.7 11.5 7.2 204 4 214 305 8.5 0 8.7 8.4 07/07/2005 11:10:00 9.6 0.5 10.7 8 9.5 0.7 11.1 7.2 201 5 200 305 8.6 0 8.7 8.4 07/07/2005 11:20:00 9.8 0.7 11.5 7.6 9.6 0.7 11.5 7.2 199 5 205 305 8.7 0 8.9 8.4 07/07/2005 11:30:00 9.6 0.7 11.5 7.6 9.2 0.8 11.5 6.8 198 6 205 305 8.8 0 8.9 8.7 07/07/2005 11:40:00 8.9 0.8 11.5 6.1 8.7 0.8 11.1 6.1 196 6 194 305 8.8 0 9.2 8.7 07/07/2005 11:50:00 9 0.8 11.1 6.5 8.9 0.9 11.1 6.5 194 6 193 305 9 0 9.2 8.9 07/07/2005 12:00:00 8.8 0.8 11.5 6.8 8.7 0.8 10.7 6.8 196 6 194 305 9 0 9.2 8.9 07/07/2005 12:10:00 9.1 0.7 10.7 6.8 8.9 0.8 11.1 6.5 194 6 192 305 9.1 0 9.5 8.9 07/07/2005 12:20:00 9.1 0.7 11.1 6.5 9 0.8 11.1 6.5 193 6 208 305 9.2 0 9.5 9.2 07/07/2005 12:30:00 9.2 0.8 11.5 6.8 9.1 0.9 11.5 6.8 196 6 192 305 9.3 0.1 10 9.2 07/07/2005 12:40:00 9 0.8 11.1 6.5 8.9 0.9 11.5 6.1 195 6 203 305 9.4 0 10 9.2 07/07/2005 12:50:00 9.3 0.8 11.1 7.2 9.3 0.9 11.5 6.5 196 7 192 305 9.5 0 10 9.5 07/07/2005 13:00:00 9.6 0.6 11.5 7.6 9.4 0.6 11.1 7.6 199 6 198 305 9.5 0 9.7 9.5 07/07/2005 13:10:00 10 0.7 11.8 8 9.8 0.8 11.8 6.8 198 5 203 305 9.4 0 9.7 9.2 07/07/2005 13:20:00 9.8 0.7 11.5 7.6 9.6 0.8 11.5 7.2 195 6 204 305 9.5 0 9.7 9.2 07/07/2005 13:30:00 10.2 0.7 11.8 8.4 10 0.7 12.2 8 195 5 196 305 9.5 0 9.7 9.5 07/07/2005 13:40:00 9.4 0.8 11.5 7.6 9.2 0.8 11.1 7.2 196 6 196 305 9.6 0 10 9.5 07/07/2005 13:50:00 9.2 0.6 11.1 6.8 9.1 0.7 10.7 6.8 197 5 199 305 9.3 0 9.7 9.2 07/07/2005 14:00:00 9.7 0.8 11.5 6.8 9.4 0.9 11.5 6.5 199 5 209 305 9.4 0.1 9.7 9.2 07/07/2005 14:10:00 9.9 0.6 11.5 8 9.8 0.6 11.5 8 203 5 200 305 9.2 0 9.5 9.2 07/07/2005 14:20:00 9.8 0.7 12.6 8 9.7 0.7 11.8 7.6 203 5 208 305 9.2 0 9.7 9.2 07/07/2005 14:30:00 9.8 0.7 11.5 7.6 9.8 0.7 11.5 7.6 204 5 210 305 9.2 0 9.7 9.2 07/07/2005 14:40:00 9.6 0.6 11.5 7.6 9.5 0.7 11.1 7.6 205 5 205 305 9.2 0 9.7 9.2 07/07/2005 14:50:00 9.4 0.8 11.5 7.2 9.1 0.9 11.5 6.1 208 6 215 305 9.3 0.1 10 9.2 07/07/2005 15:00:00 9.6 0.7 11.5 8 9.4 0.7 11.5 7.2 208 5 218 305 9.3 0 9.5 9.2 07/07/2005 15:10:00 9.3 0.7 11.5 6.8 9 0.7 11.1 6.8 210 5 212 305 9.3 0 9.7 9.2 07/07/2005 15:20:00 9.3 0.5 10.7 8 9.1 0.6 10.7 6.8 208 4 206 305 9.3 0 9.7 9.2 07/07/2005 15:30:00 9.7 0.6 11.1 8 9.6 0.6 11.5 7.6 207 4 208 305 9.3 0.1 9.7 9.2 07/07/2005 15:40:00 10 0.6 11.5 8 9.9 0.7 11.5 7.6 206 5 206 305 9.3 0.1 9.7 9.2 07/07/2005 15:50:00 9.9 0.6 11.5 8 9.6 0.7 11.5 7.2 206 4 201 305 9.5 0 10 9.5 07/07/2005 16:00:00 9.8 0.6 11.5 7.2 9.6 0.7 11.1 6.8 207 4 208 305 9.5 0 10 9.5 07/07/2005 16:10:00 10.1 0.7 12.2 7.6 10.1 0.7 11.8 7.6 206 5 209 305 9.5 0 10 9.2 07/07/2005 16:20:00 10.5 0.7 12.2 8.8 10.3 0.7 12.2 8 207 5 208 305 9.4 0.1 9.7 9.2 07/07/2005 16:30:00 10.1 0.9 12.2 6.8 9.7 1.1 12.2 6.8 209 6 202 305 9.5 0.1 10.2 9.2 07/07/2005 16:40:00 10.1 0.8 11.8 6.8 9.8 0.9 12.2 7.2 209 5 205 305 9.3 0.1 9.7 9.2 07/07/2005 16:50:00 9.6 0.8 11.5 6.8 9.1 0.9 10.7 6.5 215 6 215 305 9.4 0 10 9.2 07/07/2005 17:00:00 9.3 1 12.6 6.8 8.8 1.1 11.5 6.1 214 6 216 305 9.6 0 10 9.5 07/07/2005 17:10:00 10.2 1 12.6 7.2 9.6 1.2 12.6 6.8 215 7 224 305 9.3 0 9.7 9.2 07/07/2005 17:20:00 10.1 0.8 12.2 7.6 9.8 1 11.8 6.8 212 5 217 305 9.3 0 9.7 9.2 07/07/2005 17:30:00 10.8 0.7 12.2 8.4 10.6 0.7 12.2 8.4 207 5 205 305 9.1 0 9.5 8.9 07/07/2005 17:40:00 10.9 0.8 12.6 8.4 10.5 0.9 12.6 7.2 210 5 209 305 9.1 0 9.7 8.9 07/07/2005 17:50:00 9.4 0.9 11.5 7.2 9.2 1 11.5 6.5 219 6 224 305 9.1 0 9.7 8.9 07/07/2005 18:00:00 9.4 0.7 11.1 7.2 9 0.8 10.7 6.8 223 6 223 305 9 0 9.5 8.9 07/07/2005 18:10:00 9.5 1 11.5 6.5 9.1 1 11.5 6.1 217 6 217 305 9.1 0 9.5 8.9 07/07/2005 18:20:00 9.9 0.8 11.8 7.6 9.6 0.8 11.5 6.8 216 5 216 305 8.9 0 9.5 8.9 07/07/2005 18:30:00 10.5 0.9 12.6 7.2 10.1 1 12.2 6.8 214 5 227 305 8.9 0 9.2 8.9 07/07/2005 18:40:00 9.4 0.9 11.8 7.2 8.9 1 11.5 6.1 214 5 217 305 8.9 0 9.2 8.9 07/07/2005 18:50:00 9.8 0.8 11.8 7.2 9.3 1 11.8 6.8 212 6 220 305 8.8 0 8.9 8.7 07/07/2005 19:00:00 10 0.8 11.8 6.8 9.5 0.9 11.5 6.5 211 5 211 305 8.8 0 8.9 8.7 07/07/2005 19:10:00 10.6 1 12.6 7.2 10 1.2 12.6 6.5 212 5 212 305 8.8 0 8.9 8.7 07/07/2005 19:20:00 10.8 0.9 12.6 7.6 10.3 0.9 12.6 7.6 213 5 200 305 8.7 0 8.9 8.4 07/07/2005 19:30:00 10.2 0.8 12.2 8 10 0.9 12.2 6.8 209 5 211 305 8.6 0 8.9 8.4 07/07/2005 19:40:00 10.4 0.8 11.8 7.2 9.9 1 11.8 7.2 211 5 217 305 8.6 0 8.9 8.4 07/07/2005 19:50:00 10.3 0.7 12.2 7.6 9.9 0.8 11.8 6.8 212 5 219 305 8.6 0 8.7 8.4 07/07/2005 20:00:00 9.6 0.9 11.5 6.8 9.1 0.9 11.5 6.5 215 6 215 305 8.5 0 8.7 8.2 07/07/2005 20:10:00 9.8 0.8 11.5 7.6 9.3 0.9 11.5 6.8 212 5 215 305 8.6 0 8.7 8.4 07/07/2005 20:20:00 9.7 0.9 11.5 6.8 9 1 11.5 6.5 213 5 211 305 8.6 0 8.7 8.4 07/07/2005 20:30:00 9.5 0.8 11.8 6.8 9.1 1 11.1 6.5 211 5 211 305 8.6 0 8.7 8.4 07/07/2005 20:40:00 10.1 0.8 11.8 7.6 9.5 1 11.8 6.8 213 5 221 305 8.6 0 8.7 8.4 07/07/2005 20:50:00 6.5 1.7 9.9 3.8 6.3 1.6 9.5 3.4 228 12 211 305 8.6 0 8.7 8.4 07/07/2005 21:00:00 4.9 0.6 6.5 3.4 4.7 0.6 6.1 3.4 231 7 245 305 8.4 0 8.7 7.9 07/07/2005 21:10:00 6 0.6 7.2 3.8 5.8 0.6 7.2 4.2 231 5 228 305 8.5 0 8.7 8.4 07/07/2005 21:20:00 5 0.6 6.5 3.8 4.8 0.7 6.5 3.4 226 6 223 305 8.6 0 8.7 8.4 07/07/2005 21:30:00 5.8 0.5 7.6 4.6 5.4 0.6 6.8 3.8 236 9 228 305 8.4 0 8.7 8.2 07/07/2005 21:40:00 5.2 1 7.2 3 4.7 0.9 6.8 3 232 7 229 305 8.5 0 8.7 8.2 07/07/2005 21:50:00 4.8 0.6 6.5 3.4 4.5 0.6 6.1 3 237 7 227 305 8.5 0 8.7 8.4 07/07/2005 22:00:00 4.6 0.6 6.5 3.4 4.3 0.6 5.7 3 236 7 236 305 8.5 0 8.7 8.4 07/07/2005 22:10:00 4.9 0.5 6.1 3.4 4.6 0.6 6.1 3.4 237 6 232 305 8.4 0 8.4 8.2 07/07/2005 22:20:00 5.3 0.6 6.5 3.8 5 0.6 6.5 3.4 236 5 231 305 8.4 0 8.7 8.2 07/07/2005 22:30:00 4.6 0.6 6.1 3 4.4 0.6 5.7 3 232 8 223 305 8.4 0 8.4 8.4 07/07/2005 22:40:00 4.4 0.5 5.7 3 4.2 0.5 5.3 2.6 231 6 231 305 8.4 0 8.4 8.2 07/07/2005 22:50:00 3.6 0.5 5.3 2.3 3.4 0.6 4.9 2.3 234 6 237 305 8.4 0 8.4 8.2 07/07/2005 23:00:00 3.1 0.4 3.8 1.9 3 0.4 4.2 1.9 239 6 242 305 8.3 0 8.4 8.2 07/07/2005 23:10:00 1.8 0.5 3 0.7 2.2 0.4 3.4 1.1 226 8 230 305 8.3 0 8.4 8.2 07/07/2005 23:20:00 0.8 0.6 2.6 0.4 1.3 0.6 2.6 0.4 225 9 230 305 8.4 0 8.4 8.2 07/07/2005 23:30:00 1.4 0.5 2.6 0.4 1.7 0.4 2.6 0.7 247 9 264 305 8.4 0 8.4 8.2 07/07/2005 23:40:00 1 0.7 2.6 0.4 1.5 0.5 3 0.7 246 16 247 305 8.4 0 8.4 8.2 07/07/2005 23:50:00 2.5 0.5 3.8 0.7 2.5 0.6 3.8 1.1 257 8 253 305 8.3 0 8.4 8.2 07/08/2005 00:00:00 2 0.6 3 0.4 1.7 0.5 2.6 0.7 269 9 269 305 8.2 0 8.4 8.2 07/08/2005 00:10:00 1.3 0.6 2.3 0.4 1.4 0.4 2.6 0.4 285 12 270 305 8.3 0 8.4 8.2 07/08/2005 00:20:00 3.9 1.2 5.7 0.7 4.2 1.2 5.7 1.1 2 28 20 305 7.5 0.5 8.4 6.9 07/08/2005 00:30:00 5.7 0.7 6.8 4.2 5.8 0.8 7.2 4.2 22 5 20 305 6.9 0 7.2 6.4 07/08/2005 00:40:00 7.1 0.4 7.6 5.7 7.2 0.5 8.4 6.1 28 4 24 305 6.3 0.1 6.7 5.9 07/08/2005 00:50:00 7.6 0.5 8.4 6.1 7.7 0.6 8.8 6.1 34 3 35 305 6 0 6.1 5.9 07/08/2005 01:00:00 8.2 0.6 9.9 6.8 8.2 0.6 9.9 6.8 37 4 37 305 5.8 0 5.9 5.6 07/08/2005 01:10:00 8.6 0.5 9.5 6.8 8.6 0.6 9.5 6.1 40 4 39 305 5.6 0 5.9 5.4 07/08/2005 01:20:00 8.9 0.5 10.3 7.2 8.7 0.7 10.3 6.8 47 4 48 305 5.5 0 5.6 5.4 07/08/2005 01:30:00 9.3 0.6 10.7 7.2 9.2 0.6 10.3 7.2 48 4 47 305 5.4 0 5.6 5.4 07/08/2005 01:40:00 9.8 0.4 10.7 8.8 9.7 0.4 10.7 8.4 47 4 43 305 5.4 0 5.6 5.4 07/08/2005 01:50:00 9.9 0.6 11.1 8.4 9.8 0.6 11.1 8 48 3 52 305 5.4 0 5.6 5.4 07/08/2005 02:00:00 9.9 0.6 11.1 7.6 9.8 0.6 10.7 8 48 3 50 305 5.4 0 5.6 5.4 07/08/2005 02:10:00 9.8 0.4 10.7 8.4 9.7 0.5 11.1 8.4 44 3 48 305 5.3 0 5.4 4.9 07/08/2005 02:20:00 9.5 0.5 10.3 7.6 9.4 0.6 10.3 7.2 44 3 48 305 5 0.1 5.4 4.9 07/08/2005 02:30:00 9.2 0.6 10.3 6.8 9.1 0.6 10.3 6.8 41 3 41 305 4.9 0 5.2 4.9 07/08/2005 02:40:00 9.5 0.5 10.3 7.2 9.5 0.5 10.3 7.2 44 3 50 305 4.8 0 5.2 4.9 07/08/2005 02:50:00 9.4 0.6 10.7 7.6 9.3 0.7 10.7 7.2 44 4 37 305 4.8 0 5.2 4.7 07/08/2005 03:00:00 9.6 0.5 11.1 8 9.6 0.5 10.7 7.6 42 3 42 305 4.8 0 5.2 4.7 07/08/2005 03:10:00 9.3 0.4 10.3 7.6 9.2 0.5 10.3 7.6 43 3 39 305 4.8 0 5.2 4.9 07/08/2005 03:20:00 8.9 0.4 9.9 7.2 8.8 0.5 9.9 6.8 48 3 50 305 4.9 0 5.4 4.9 07/08/2005 03:30:00 8.7 0.4 9.5 7.6 8.7 0.5 9.5 7.2 46 3 43 305 5 0 5.4 4.9 07/08/2005 03:40:00 8.7 0.4 9.5 7.2 8.7 0.5 9.5 6.8 46 3 51 305 5 0.1 5.4 4.9 07/08/2005 03:50:00 8.6 0.5 9.5 6.8 8.6 0.5 9.5 6.8 44 3 40 305 4.9 0 5.4 4.9 07/08/2005 04:00:00 8.1 0.5 9.1 6.8 8 0.5 9.5 6.5 46 4 54 305 5 0.1 5.4 4.9 07/08/2005 04:10:00 8.3 0.5 9.5 6.8 8.2 0.6 9.1 6.5 46 3 44 305 5 0 5.4 4.9 07/08/2005 04:20:00 8.5 0.4 9.1 7.2 8.4 0.5 9.1 7.2 48 3 48 305 4.9 0 5.4 4.9 07/08/2005 04:30:00 8.3 0.6 9.5 6.5 8.1 0.7 9.5 5.7 51 4 48 305 5 0.1 5.4 4.9 07/08/2005 04:40:00 8 0.5 8.8 6.5 8 0.5 9.1 5.7 50 3 54 305 4.9 0.1 5.4 4.9 07/08/2005 04:50:00 7.3 0.8 8.4 4.9 7.3 0.8 8.8 4.9 50 4 53 305 4.9 0 5.2 4.7 07/08/2005 05:00:00 7.5 0.6 8.8 6.1 7.5 0.6 8.8 6.1 49 4 55 305 4.9 0 5.4 4.7 07/08/2005 05:10:00 7.4 0.6 8.4 5.3 7.3 0.6 8.4 5.3 49 4 49 305 4.9 0 5.2 4.7 07/08/2005 05:20:00 7.4 0.6 8.4 6.1 7.3 0.6 8.8 5.7 50 4 46 305 4.9 0 5.4 4.7 07/08/2005 05:30:00 7.1 0.6 8 5.7 7 0.7 8.4 4.9 49 4 45 305 4.9 0 5.4 4.9 07/08/2005 05:40:00 7.7 0.3 8.4 6.5 7.7 0.4 8.4 6.1 47 3 47 305 4.9 0 5.4 4.9 07/08/2005 05:50:00 7.1 0.4 8 6.1 7.1 0.4 8 5.7 46 3 46 305 4.9 0 5.4 4.9 07/08/2005 06:00:00 6.4 0.4 7.2 4.9 6.5 0.5 7.2 4.6 45 3 51 305 4.9 0 5.4 4.9 07/08/2005 06:10:00 6.7 0.4 7.6 5.3 6.7 0.5 7.6 5.3 47 3 50 305 5 0.1 5.4 4.9 07/08/2005 06:20:00 7.1 0.3 7.6 6.1 7.1 0.3 7.6 5.7 46 4 48 305 4.9 0.1 5.4 4.9 07/08/2005 06:30:00 6.7 0.3 7.2 5.7 6.7 0.4 7.2 5.7 47 3 51 305 4.9 0 5.4 4.9 07/08/2005 06:40:00 6.2 0.4 6.8 5.3 6.2 0.4 7.2 4.9 47 4 50 305 4.9 0.1 5.4 4.9 07/08/2005 06:50:00 6.6 0.4 7.6 5.7 6.6 0.5 7.6 5.3 47 2 43 305 4.9 0 5.4 4.9 07/08/2005 07:00:00 7 0.5 8 5.3 7.1 0.5 8 5.3 47 4 51 305 4.9 0 5.4 4.7 07/08/2005 07:10:00 6 0.4 6.8 4.6 6 0.4 6.8 4.9 49 4 56 305 4.9 0 5.4 4.7 07/08/2005 07:20:00 5.7 0.4 6.5 4.9 5.7 0.4 6.5 4.2 52 3 48 305 4.8 0 5.4 4.7 07/08/2005 07:30:00 5.2 0.4 6.1 4.2 5.2 0.3 6.1 4.2 58 4 64 305 4.9 0 5.4 4.7 07/08/2005 07:40:00 5.1 0.4 6.1 3.8 5.1 0.4 6.1 3.4 59 5 54 305 4.9 0.1 5.4 4.9 07/08/2005 07:50:00 3.7 0.8 5.3 2.3 3.7 0.7 5.7 2.3 68 12 57 305 5.2 0 5.6 4.9 07/08/2005 08:00:00 1.7 1.1 4.2 0.4 2.1 0.9 4.2 0.4 63 15 70 305 5.3 0 5.9 5.2 07/08/2005 08:10:00 1.2 0.8 3.4 0.4 1.7 0.6 3.4 0.4 74 20 56 305 5.5 0.1 5.9 5.4 07/08/2005 08:20:00 1.6 1 4.2 0.4 2.1 0.9 4.2 0.4 50 13 53 305 5.6 0 5.9 5.4 07/08/2005 08:30:00 2.9 0.8 4.9 1.1 3.5 0.6 4.9 1.9 45 12 49 305 5.6 0 5.9 5.4 07/08/2005 08:40:00 2.4 1 4.9 0.4 3 1.1 5.7 0.7 65 27 36 305 6 0.3 6.9 5.6 07/08/2005 08:50:00 2 0.9 4.2 0.4 2.3 0.7 4.2 0.7 79 24 82 305 7 0.3 7.7 6.4 07/08/2005 09:00:00 1.6 1 4.2 0.4 2.2 0.9 5.3 0.4 0 72 82 305 7.7 0.2 8.4 7.4 07/08/2005 09:10:00 3 1.3 6.1 0.4 3.3 1.1 5.7 0.4 255 41 276 305 7.9 0.4 8.7 7.4 07/08/2005 09:20:00 1.5 1 4.6 0.4 2 0.9 4.2 0.4 352 72 119 305 7.8 0.1 8.2 7.4 07/08/2005 09:30:00 2.5 1.3 4.9 0.4 2.7 1.2 4.9 0.4 321 53 276 305 8.5 0.2 8.9 7.9 07/08/2005 09:40:00 1.7 1.2 4.2 0.4 1.9 1.2 4.2 0.4 280 58 275 305 8 0.1 8.4 7.7 07/08/2005 09:50:00 0.8 0.8 3 0.4 1 1 3.4 0.4 39 23 49 305 8.6 0.1 8.9 8.2 07/08/2005 10:00:00 2.1 1 4.9 0.4 2.4 0.7 3.8 0.4 4 69 69 305 7.9 0.2 8.4 7.4 07/08/2005 10:10:00 1.4 0.7 3.4 0.4 2.3 0.6 3.8 0.7 334 33 334 305 7.6 0 7.9 7.4 07/08/2005 10:20:00 2 0.5 3.4 0.7 2.3 0.5 3.4 1.1 269 20 284 305 7.8 0.1 8.2 7.7 07/08/2005 10:30:00 1.3 0.7 3 0.4 1.5 0.7 3 0.4 233 22 258 305 8.4 0.1 8.9 7.9 07/08/2005 10:40:00 2.2 1 4.9 0.4 2.4 0.9 4.6 0.4 234 20 230 305 8.8 0 8.9 8.4 07/08/2005 10:50:00 2.2 1.5 4.9 0.4 2.6 1.3 4.9 0.4 202 36 215 305 9 0.2 9.5 8.7 07/08/2005 11:00:00 1.9 1.2 4.9 0.4 2.1 1 4.9 0.4 274 41 254 305 8.7 0.1 9.2 8.4 07/08/2005 11:10:00 2.3 0.6 3.8 0.7 2.6 0.6 4.2 1.1 204 21 196 305 9.4 0.2 10.2 9.2 07/08/2005 11:20:00 4.4 0.9 6.1 1.1 4.7 0.8 6.1 1.9 195 8 191 305 9.6 0.2 10.2 9.2 07/08/2005 11:30:00 4.3 0.9 5.7 2.3 4.4 0.9 6.1 2.3 198 8 195 305 9.3 0.1 9.7 9.2 07/08/2005 11:40:00 2 0.7 3.4 0.4 2.3 0.5 3.8 1.1 202 14 196 305 9.6 0.2 10.2 9.2 07/08/2005 11:50:00 1 0.7 3.4 0.4 1.6 0.7 3.4 0.4 328 66 248 305 10 0.2 10.5 9.7 07/08/2005 12:00:00 3.1 0.5 4.2 1.5 3.2 0.5 4.2 1.9 233 8 225 305 9.5 0.2 10.2 9.2 07/08/2005 12:10:00 2.9 0.6 4.2 1.5 3.1 0.5 4.2 1.9 220 12 208 305 9.3 0.1 9.7 9.2 07/08/2005 12:20:00 3.9 0.6 5.3 2.3 4 0.6 5.7 2.6 209 8 205 305 9.4 0.1 10 9.2 07/08/2005 12:30:00 5 0.5 6.5 3.4 5 0.6 6.5 3.4 211 7 211 305 9.1 0 9.5 8.9 07/08/2005 12:40:00 6 0.6 7.2 4.2 5.9 0.7 7.6 4.2 216 7 218 305 9.1 0 9.2 8.9 07/08/2005 12:50:00 6.1 0.5 7.2 4.6 6.1 0.6 7.6 4.2 209 5 215 305 8.7 0.1 9.2 8.4 07/08/2005 13:00:00 6.5 0.5 7.6 4.9 6.5 0.5 7.6 4.2 208 5 199 305 8.6 0 8.9 8.4 07/08/2005 13:10:00 6.3 0.4 7.2 5.3 6.3 0.4 7.2 4.9 204 4 203 305 8.5 0 8.9 8.4 07/08/2005 13:20:00 5.8 0.5 7.2 4.2 5.7 0.5 7.2 3.8 212 6 215 305 8.4 0 8.7 8.2 07/08/2005 13:30:00 5.2 0.5 6.5 3.8 5.1 0.6 6.5 3.4 211 7 219 305 8.6 0 9.2 8.4 07/08/2005 13:40:00 5.2 0.6 6.8 3.8 5.2 0.6 6.5 3.4 207 7 211 305 8.5 0 8.9 8.2 07/08/2005 13:50:00 6 0.5 7.2 4.6 5.9 0.5 7.6 3.8 205 6 208 305 8.6 0 9.2 8.4 07/08/2005 14:00:00 6.7 0.7 8.4 4.6 6.7 0.7 8.4 4.6 205 6 208 305 8.5 0 9.2 8.4 07/08/2005 14:10:00 6.7 0.7 8.4 4.6 6.8 0.8 8 4.6 209 6 211 305 8.6 0 9.2 8.4 07/08/2005 14:20:00 6.7 0.6 8.4 4.9 6.7 0.7 8 4.9 206 6 214 305 8.8 0.1 9.5 8.7 07/08/2005 14:30:00 6.7 0.5 8 5.3 6.6 0.6 8 4.9 205 5 212 305 8.9 0.1 9.5 8.7 07/08/2005 14:40:00 6.3 0.5 7.6 4.6 6.2 0.5 7.6 4.6 207 5 204 305 8.9 0.1 9.5 8.7 07/08/2005 14:50:00 6.7 0.5 8 5.3 6.7 0.5 8 4.9 206 6 205 305 8.8 0 9.5 8.7 07/08/2005 15:00:00 5.7 0.7 7.2 3.4 5.7 0.7 7.6 4.2 210 6 207 305 8.9 0.1 9.5 8.7 07/08/2005 15:10:00 6 0.6 7.6 4.2 6 0.6 7.2 4.6 208 5 208 305 9 0.2 9.7 8.7 07/08/2005 15:20:00 7 0.6 8.4 5.3 6.9 0.7 8.4 4.9 206 5 208 305 8.7 0 9.2 8.4 07/08/2005 15:30:00 7 0.6 8 4.9 6.9 0.6 8 5.3 202 7 203 305 8.5 0 8.7 8.4 07/08/2005 15:40:00 7.6 0.7 9.1 5.7 7.5 0.7 9.1 5.3 193 5 194 305 8.5 0 8.7 8.4 07/08/2005 15:50:00 8.1 0.6 9.5 5.3 7.9 0.7 9.5 4.9 195 4 197 305 8.6 0 8.9 8.4 07/08/2005 16:00:00 8.5 0.5 9.9 6.5 8.3 0.7 9.9 5.3 196 4 195 305 8.8 0 8.9 8.7 07/08/2005 16:10:00 8.7 0.6 10.3 6.8 8.5 0.6 9.9 6.5 201 4 208 305 8.8 0 8.9 8.4 07/08/2005 16:20:00 8.7 0.5 10.3 7.2 8.6 0.6 9.9 6.5 201 5 201 305 8.6 0 8.7 8.4 07/08/2005 16:30:00 8.5 0.5 9.9 6.8 8.3 0.6 9.9 6.5 199 7 194 305 8.6 0 8.9 8.4 07/08/2005 16:40:00 8.5 0.6 9.9 6.5 7.9 0.9 9.9 5.7 211 5 210 305 8.7 0 8.9 8.4 07/08/2005 16:50:00 7.7 0.8 9.5 4.9 7.3 0.9 9.1 4.9 212 6 217 305 8.8 0 8.9 8.7 07/08/2005 17:00:00 8.2 0.6 9.5 6.1 7.7 0.7 9.5 5.7 217 5 214 305 8.7 0 8.9 8.4 07/08/2005 17:10:00 8.1 0.7 9.5 6.1 7.6 0.8 9.1 5.3 220 5 215 305 8.6 0 8.9 8.4 07/08/2005 17:20:00 8.5 0.7 9.9 6.5 8 0.7 9.9 6.1 222 5 214 305 8.6 0 8.7 8.4 07/08/2005 17:30:00 8.2 0.8 9.9 6.1 7.6 0.9 9.9 5.7 224 5 224 305 8.4 0 8.7 8.2 07/08/2005 17:40:00 9 0.7 10.7 6.8 8.4 0.8 9.9 6.5 231 5 227 305 8.1 0 8.4 7.9 07/08/2005 17:50:00 8.3 0.7 9.5 6.5 7.5 0.7 9.1 5.3 233 5 234 305 8 0 8.2 7.9 07/08/2005 18:00:00 7.8 0.7 9.5 5.7 7.3 0.8 9.1 5.3 228 5 234 305 8.1 0 8.2 7.9 07/08/2005 18:10:00 7.6 0.7 8.8 5.3 7 0.8 8.4 4.9 228 5 224 305 8.2 0 8.2 8.2 07/08/2005 18:20:00 7.5 0.7 9.5 5.7 6.8 0.8 9.1 4.6 226 6 232 305 8.2 0 8.2 8.2 07/08/2005 18:30:00 8.2 0.7 10.3 5.7 7.4 0.8 9.5 5.3 226 5 230 305 8.2 0 8.2 8.2 07/08/2005 18:40:00 8 0.8 9.5 5.7 7.2 0.8 9.1 5.3 228 5 229 305 8.1 0 8.2 7.9 07/08/2005 18:50:00 8.5 0.6 9.9 6.5 7.9 0.8 9.9 5.7 230 5 228 305 8.1 0 8.2 7.9 07/08/2005 19:00:00 8 0.7 9.5 6.1 7.4 0.8 9.1 5.3 226 5 225 305 8.2 0 8.2 8.2 07/08/2005 19:10:00 8.3 0.7 9.9 5.7 7.7 0.7 9.5 5.3 228 5 226 305 8.1 0 8.2 7.9 07/08/2005 19:20:00 8.7 0.8 10.3 6.1 8 0.9 9.9 5.7 234 6 235 305 8.2 0 8.2 7.9 07/08/2005 19:30:00 8 0.7 9.5 5.7 7.3 0.8 9.1 4.9 234 5 235 305 8.1 0 8.2 7.9 07/08/2005 19:40:00 7.8 0.6 9.5 6.1 7.2 0.8 9.1 5.3 229 4 225 305 8 0 8.2 7.9 07/08/2005 19:50:00 8.3 0.7 9.9 6.1 7.6 0.8 9.5 5.7 228 5 231 305 8.1 0 8.2 7.9 07/08/2005 20:00:00 8.7 0.6 10.3 6.8 8 0.8 9.9 5.7 230 5 221 305 8 0 8.2 7.9 07/08/2005 20:10:00 8.9 0.7 10.3 6.8 8.2 0.7 9.9 6.1 231 5 235 305 8 0 8.2 7.9 07/08/2005 20:20:00 9.2 0.7 11.5 7.6 8.7 0.7 10.7 6.8 232 5 232 305 8.1 0 8.2 7.9 07/08/2005 20:30:00 9.2 0.8 10.7 6.8 8.4 0.8 10.3 5.7 234 5 236 305 8.1 0 8.2 8.2 07/08/2005 20:40:00 9.6 0.9 11.5 7.2 8.7 1 11.1 6.1 235 5 239 305 8.2 0 8.2 8.2 07/08/2005 20:50:00 9.8 0.8 11.8 7.2 8.8 1 11.5 6.1 235 5 244 305 8.2 0 8.2 8.2 07/08/2005 21:00:00 9.9 0.7 11.8 8 9.3 0.8 11.5 6.8 231 5 224 305 8.1 0 8.2 7.9 07/08/2005 21:10:00 9.8 0.8 11.1 6.5 9.1 0.9 10.7 6.5 235 5 237 305 8.1 0 8.2 7.9 07/08/2005 21:20:00 9.1 0.8 11.1 7.2 8.4 1 10.3 6.1 232 5 228 305 8.1 0 8.2 7.9 07/08/2005 21:30:00 9.5 0.6 11.1 7.2 8.9 0.8 10.7 6.8 231 4 235 305 8.1 0 8.2 7.9 07/08/2005 21:40:00 10.2 0.8 12.2 7.6 9.7 0.9 11.8 6.8 229 5 230 305 8.1 0 8.2 7.9 07/08/2005 21:50:00 10 0.8 11.5 8 9.4 0.9 11.5 6.8 232 5 232 305 8.1 0 8.2 7.9 07/08/2005 22:00:00 9.4 0.7 11.1 7.2 8.8 0.9 10.7 6.5 229 5 231 305 8.1 0 8.2 7.9 07/08/2005 22:10:00 9.8 0.8 11.5 7.6 9.2 0.9 11.5 7.2 230 5 230 305 8.1 0 8.2 7.9 07/08/2005 22:20:00 9.9 0.9 11.8 7.2 9.1 1 11.5 6.8 232 5 234 305 8 0 8.2 7.9 07/08/2005 22:30:00 9.7 0.7 11.5 7.2 9.1 0.8 11.1 6.8 230 5 232 305 8 0 8.2 7.9 07/08/2005 22:40:00 10.2 1 12.2 6.8 9.3 1.1 11.8 6.5 230 6 234 305 8 0 8.2 7.9 07/08/2005 22:50:00 10.2 0.8 12.2 7.6 9.3 0.9 11.5 6.5 233 5 230 305 7.9 0 8.2 7.9 07/08/2005 23:00:00 9.8 0.9 11.8 7.2 9 1 11.5 6.1 228 5 222 305 7.9 0 8.2 7.9 07/08/2005 23:10:00 10.3 0.8 12.6 7.6 9.5 1 11.8 6.1 229 6 232 305 7.9 0 7.9 7.9 07/08/2005 23:20:00 10.1 0.8 12.6 7.2 9.5 0.9 11.8 6.8 227 6 234 305 7.9 0 7.9 7.9 07/08/2005 23:30:00 9.2 0.8 11.1 6.1 8.6 1 10.3 5.3 210 7 208 305 8 0 8.2 7.9 07/08/2005 23:40:00 10 0.8 12.2 8 9.2 0.9 11.5 6.8 223 6 231 305 8 0 8.2 7.9 07/08/2005 23:50:00 11 0.7 12.6 8.8 10.1 0.9 11.8 7.2 227 5 221 305 7.9 0 8.2 7.7 07/09/2005 00:00:00 11.2 1 13 8 10.4 1.1 13 7.2 227 4 221 305 7.9 0 8.2 7.9 07/09/2005 00:10:00 9.9 0.9 12.2 6.8 9.1 1 11.5 6.8 227 6 225 305 7.9 0 8.2 7.9 07/09/2005 00:20:00 9.8 0.7 11.8 7.6 9.1 0.9 11.5 6.5 231 5 231 305 7.9 0 7.9 7.7 07/09/2005 00:30:00 10 0.8 11.8 7.2 9.3 1 11.5 6.5 231 5 227 305 7.9 0 7.9 7.7 07/09/2005 00:40:00 9.8 0.8 11.5 7.2 9.2 0.9 11.1 6.1 230 5 234 305 7.8 0 7.9 7.7 07/09/2005 00:50:00 10.5 0.7 12.2 8.4 9.7 0.8 11.5 7.6 230 4 225 305 7.9 0 7.9 7.7 07/09/2005 01:00:00 9.7 0.8 11.5 7.6 9.1 0.9 11.1 6.8 230 5 239 305 7.9 0 7.9 7.7 07/09/2005 01:10:00 9.6 1 11.8 6.8 9 1 11.1 6.8 229 5 227 305 7.9 0 7.9 7.7 07/09/2005 01:20:00 10.1 1 12.6 6.8 9.4 1.1 12.2 6.5 227 5 220 305 7.9 0 7.9 7.7 07/09/2005 01:30:00 10 0.9 12.6 7.6 9.4 0.9 11.8 7.2 231 5 235 305 7.8 0 7.9 7.7 07/09/2005 01:40:00 10.1 0.8 12.2 8 9.6 0.8 11.8 7.2 230 5 227 305 7.8 0 7.9 7.7 07/09/2005 01:50:00 10 1 12.2 7.2 9.3 1.1 11.8 6.5 226 5 231 305 7.8 0 7.9 7.7 07/09/2005 02:00:00 9.5 0.8 12.2 7.2 8.8 0.9 11.8 6.8 227 6 228 305 7.8 0 7.9 7.7 07/09/2005 02:10:00 9.6 0.8 11.5 7.2 8.9 0.8 11.1 6.1 226 6 227 305 7.8 0 7.9 7.7 07/09/2005 02:20:00 9.5 0.8 11.1 7.2 8.8 0.9 11.1 6.5 228 6 225 305 7.8 0 7.9 7.7 07/09/2005 02:30:00 9.3 0.8 11.1 7.2 8.5 0.9 10.7 6.1 232 5 231 305 7.7 0 7.9 7.7 07/09/2005 02:40:00 9.1 0.8 11.5 7.2 8.5 0.8 10.7 6.5 232 5 229 305 7.7 0 7.9 7.7 07/09/2005 02:50:00 8.6 0.8 10.3 6.5 7.9 0.8 10.7 5.7 228 7 225 305 7.7 0 7.9 7.7 07/09/2005 03:00:00 9.1 0.6 10.7 7.2 8.6 0.8 10.7 6.1 227 5 224 305 7.7 0 7.9 7.7 07/09/2005 03:10:00 8.8 0.8 11.1 6.1 8.1 1 10.3 5.7 226 5 226 305 7.7 0 7.9 7.7 07/09/2005 03:20:00 9.8 1 12.2 6.5 9.1 1.2 11.8 6.1 227 5 233 305 7.7 0 7.9 7.7 07/09/2005 03:30:00 9.8 1 12.2 6.8 9.1 1 11.1 6.8 222 5 221 305 7.7 0 7.9 7.7 07/09/2005 03:40:00 9.9 0.9 11.8 6.5 9.3 1.1 11.8 6.5 215 5 211 305 7.7 0 7.9 7.7 07/09/2005 03:50:00 10 1 12.2 7.2 9.4 1.1 12.2 6.8 219 5 218 305 7.7 0 7.9 7.7 07/09/2005 04:00:00 9.7 0.9 12.2 7.6 9.3 0.9 11.8 6.8 217 5 221 305 7.7 0 7.9 7.7 07/09/2005 04:10:00 9.3 1 12.2 6.5 8.7 1 11.5 6.1 220 6 221 305 7.7 0 7.9 7.7 07/09/2005 04:20:00 9.3 1 11.8 5.7 8.7 1.1 11.8 5.7 222 6 221 305 7.7 0 7.9 7.7 07/09/2005 04:30:00 9.5 1 12.2 6.5 8.6 1 11.8 6.1 226 6 218 305 7.6 0 7.7 7.7 07/09/2005 04:40:00 8.6 1 10.7 6.1 8.1 1 10.3 5.7 226 6 220 305 7.6 0 7.7 7.4 07/09/2005 04:50:00 9 0.8 11.1 6.1 8.3 1 10.7 5.3 232 5 232 305 7.5 0 7.7 7.4 07/09/2005 05:00:00 9.6 0.7 11.5 7.6 9 0.8 11.5 6.8 229 5 230 305 7.5 0 7.7 7.4 07/09/2005 05:10:00 9.5 0.8 11.5 7.2 8.8 0.8 10.7 6.8 223 5 221 305 7.5 0 7.7 7.4 07/09/2005 05:20:00 9.4 1 12.2 6.8 8.8 1.1 12.2 6.1 224 5 231 305 7.5 0 7.7 7.4 07/09/2005 05:30:00 10.4 0.8 12.6 7.6 9.7 0.8 11.8 6.8 226 6 226 305 7.5 0 7.7 7.4 07/09/2005 05:40:00 10.2 1.1 12.6 6.8 9.5 1.1 12.2 6.8 224 6 225 305 7.5 0 7.7 7.4 07/09/2005 05:50:00 10.5 0.9 12.6 8 9.6 1 11.5 7.2 233 7 231 305 7.5 0 7.7 7.4 07/09/2005 06:00:00 9.8 0.8 11.8 7.2 9 1 11.5 6.5 232 7 244 305 7.5 0 7.7 7.4 07/09/2005 06:10:00 10.9 0.8 12.6 8 10.2 1 12.6 7.6 230 5 238 305 7.5 0 7.7 7.4 07/09/2005 06:20:00 9.2 0.8 11.5 6.8 8.4 0.9 11.1 6.1 227 6 231 305 7.5 0 7.7 7.4 07/09/2005 06:30:00 9.1 0.7 11.1 6.8 8.6 0.8 10.3 6.5 220 5 221 305 7.5 0 7.7 7.4 07/09/2005 06:40:00 10.2 0.6 11.8 8 9.7 0.7 11.1 7.2 214 5 210 305 7.6 0 7.7 7.7 07/09/2005 06:50:00 9.9 0.7 11.5 8 9.3 0.8 11.1 6.8 218 5 214 305 7.6 0 7.7 7.4 07/09/2005 07:00:00 9.9 0.8 11.8 8 9.4 1 11.5 6.8 214 5 210 305 7.6 0 7.7 7.4 07/09/2005 07:10:00 9.2 0.8 11.5 6.5 8.7 1 10.7 6.1 213 5 215 305 7.6 0 7.7 7.7 07/09/2005 07:20:00 9.7 0.8 11.8 7.6 9 1 11.5 6.5 223 6 232 305 7.6 0 7.7 7.4 07/09/2005 07:30:00 8.4 0.9 11.1 6.5 7.8 0.9 9.9 5.3 221 6 224 305 7.5 0 7.7 7.4 07/09/2005 07:40:00 9.2 0.8 10.7 6.8 8.4 1.1 10.7 5.7 235 5 234 305 7.5 0 7.7 7.4 07/09/2005 07:50:00 8.6 0.8 10.7 6.5 7.8 0.9 10.3 5.3 236 6 237 305 7.5 0 7.7 7.4 07/09/2005 08:00:00 7.6 0.8 9.5 5.7 7 0.9 9.9 4.6 239 5 239 305 7.5 0 7.7 7.4 07/09/2005 08:10:00 6.7 0.6 8 4.6 5.8 0.8 7.6 3.4 240 5 232 305 7.5 0 7.7 7.4 07/09/2005 08:20:00 6.4 0.5 7.2 4.6 5.6 0.5 7.2 3.8 237 6 242 305 7.6 0 7.7 7.4 07/09/2005 08:30:00 6.4 0.7 7.6 4.2 5.8 0.7 7.2 4.2 217 9 217 305 7.7 0 7.7 7.7 07/09/2005 08:40:00 6.6 0.7 8.4 4.6 6.3 0.8 8 3.8 208 5 204 305 7.7 0 7.9 7.7 07/09/2005 08:50:00 7.4 0.7 8.8 5.3 7 0.8 8.8 4.6 210 6 215 305 7.7 0 7.9 7.7 07/09/2005 09:00:00 8.2 0.7 9.9 6.1 7.5 0.8 9.5 5.3 212 6 213 305 7.8 0 7.9 7.7 07/09/2005 09:10:00 8.8 0.6 10.7 6.8 8.5 0.7 9.9 6.5 207 4 208 305 7.9 0 7.9 7.7 07/09/2005 09:20:00 9.8 0.5 11.5 8.4 9.6 0.6 11.1 7.6 203 3 202 305 8 0 8.2 7.9 07/09/2005 09:30:00 9.4 0.6 11.1 6.8 9.1 0.7 10.7 6.8 206 5 209 305 8 0 8.2 7.9 07/09/2005 09:40:00 9.5 0.7 10.7 6.8 9 0.8 10.3 6.5 208 5 208 305 8 0 8.2 7.9 07/09/2005 09:50:00 9.4 1 11.1 6.8 8.6 1 11.5 6.1 210 6 213 305 8 0 8.2 7.9 07/09/2005 10:00:00 9.2 0.9 11.1 6.5 8.5 1 11.1 6.1 210 5 205 305 8 0 8.2 7.9 07/09/2005 10:10:00 9.3 0.8 11.1 6.1 8.8 0.9 11.1 6.5 209 5 208 305 7.9 0 8.2 7.7 07/09/2005 10:20:00 9 0.8 11.1 6.8 8.5 1 10.7 5.7 208 5 208 305 7.9 0 8.2 7.7 07/09/2005 10:30:00 9.6 0.6 11.1 8 9.3 0.6 10.7 7.2 202 4 205 305 8 0 8.2 7.9 07/09/2005 10:40:00 8.9 0.8 10.3 6.1 8.5 1 10.3 6.1 207 6 194 305 8 0 8.2 7.9 07/09/2005 10:50:00 8.4 0.6 9.9 6.5 7.9 0.7 9.5 5.7 213 5 206 305 8 0 8.2 7.9 07/09/2005 11:00:00 8.1 0.8 10.3 6.1 7.4 0.9 9.5 5.3 211 6 218 305 8 0 8.2 7.9 07/09/2005 11:10:00 8.5 0.7 10.3 6.5 7.8 0.8 9.9 5.7 210 5 212 305 8 0 8.2 7.9 07/09/2005 11:20:00 8.6 0.7 10.3 6.1 8.3 0.8 9.9 6.1 206 5 203 305 8.1 0 8.2 7.9 07/09/2005 11:30:00 8.9 0.6 10.3 6.8 8.7 0.6 10.3 6.8 205 4 207 305 8.1 0 8.2 7.9 07/09/2005 11:40:00 9 0.5 10.7 7.6 8.8 0.6 10.3 6.8 202 4 200 305 8.2 0 8.4 8.2 07/09/2005 11:50:00 8.7 0.5 10.3 6.8 8.5 0.6 10.3 6.1 201 4 202 305 8.2 0 8.2 8.2 07/09/2005 12:00:00 8.7 0.7 10.7 6.8 8.4 0.8 10.7 6.5 199 4 196 305 8.3 0 8.4 8.2 07/09/2005 12:10:00 9 0.5 10.7 7.2 8.7 0.6 10.3 6.8 198 5 199 305 8.4 0 8.7 8.2 07/09/2005 12:20:00 9.1 0.6 10.7 7.6 8.8 0.7 10.7 6.5 195 5 193 305 8.6 0 8.9 8.4 07/09/2005 12:30:00 9.6 0.6 11.1 8 9.4 0.8 11.8 6.8 192 5 194 305 8.7 0 8.9 8.4 07/09/2005 12:40:00 9.3 0.7 11.1 6.8 9.1 0.8 11.1 6.5 194 5 203 305 8.8 0 8.9 8.7 07/09/2005 12:50:00 9 0.6 10.3 7.2 8.8 0.8 11.1 6.5 193 5 191 305 8.9 0 9.2 8.7 07/09/2005 13:00:00 8.7 0.7 10.3 6.5 8.6 0.8 10.3 5.7 195 5 196 305 8.9 0 9.2 8.9 07/09/2005 13:10:00 8.1 0.6 9.5 6.1 7.8 0.7 9.9 5.3 195 6 202 305 9.1 0 9.2 8.9 07/09/2005 13:20:00 8.1 0.8 10.7 5.3 7.9 0.9 10.3 5.3 193 7 198 305 9.1 0 9.5 8.9 07/09/2005 13:30:00 8.3 0.6 9.9 6.8 8.1 0.6 9.9 6.1 194 5 190 305 9.3 0 9.5 9.2 07/09/2005 13:40:00 8.2 0.7 9.9 6.1 7.9 0.8 9.5 5.3 195 6 198 305 9.3 0 9.5 9.2 07/09/2005 13:50:00 8.4 0.7 10.3 6.5 8.1 0.8 10.3 6.1 195 5 199 305 9.3 0 9.7 9.2 07/09/2005 14:00:00 8.6 0.6 10.3 6.8 8.3 0.7 9.9 6.1 195 6 192 305 9.7 0 10 9.2 07/09/2005 14:10:00 8.3 0.7 10.3 6.1 8.1 0.8 10.7 5.7 193 6 194 305 9.7 0 10 9.7 07/09/2005 14:20:00 8 0.7 9.9 5.7 7.8 0.8 9.5 5.3 193 6 199 305 9.7 0 10 9.5 07/09/2005 14:30:00 8.3 0.8 10.7 5.3 8.2 0.9 10.7 5.7 191 7 201 305 9.9 0 10.2 9.7 07/09/2005 14:40:00 7.9 0.6 10.3 6.5 7.7 0.7 9.5 5.3 196 6 202 305 9.7 0 10.2 9.7 07/09/2005 14:50:00 7.4 0.8 9.9 4.9 7.1 0.9 9.1 4.9 193 7 205 305 9.9 0 10.5 9.7 07/09/2005 15:00:00 7.4 0.8 9.1 4.6 7.2 0.9 9.5 4.6 195 7 198 305 9.8 0 10.2 9.7 07/09/2005 15:10:00 7.5 0.7 9.1 4.9 7.2 0.9 9.1 5.3 196 7 198 305 9.7 0 10.2 9.7 07/09/2005 15:20:00 8.6 0.5 9.5 7.2 8.5 0.6 9.9 6.8 193 5 190 305 9.8 0 10.2 9.7 07/09/2005 15:30:00 8.3 0.6 9.9 6.5 8.1 0.7 9.5 6.1 193 5 196 305 10.1 0.1 10.5 9.7 07/09/2005 15:40:00 8.7 0.7 10.3 6.5 8.4 0.8 10.3 4.9 194 5 194 305 10.2 0.1 10.5 10 07/09/2005 15:50:00 8.7 0.8 10.7 5.7 8.6 1 10.7 6.1 192 5 198 305 9.9 0 10 9.7 07/09/2005 16:00:00 8.4 0.7 9.9 6.5 8.2 0.9 9.9 5.3 194 5 196 305 9.8 0 10.2 9.7 07/09/2005 16:10:00 8.5 0.6 10.3 6.8 8.4 0.7 9.9 6.5 194 5 197 305 10 0 10.5 10 07/09/2005 16:20:00 7.5 0.7 9.5 5.7 7.2 0.8 9.5 4.6 201 5 203 305 10.2 0 10.2 10 07/09/2005 16:30:00 7.3 0.6 8.8 5.7 7.1 0.6 9.1 5.3 202 5 198 305 9.9 0 10.2 9.7 07/09/2005 16:40:00 7.4 0.7 9.5 5.7 7.1 0.7 9.1 5.3 201 6 208 305 9.9 0.1 10.2 9.7 07/09/2005 16:50:00 8 0.7 9.9 6.1 7.7 0.8 9.5 5.7 199 6 205 305 10.3 0 10.5 10.2 07/09/2005 17:00:00 8.2 0.6 9.9 6.5 8 0.7 9.5 5.7 196 5 197 305 10.6 0 10.8 10.5 07/09/2005 17:10:00 8.4 0.6 9.9 6.1 8.1 0.7 9.5 6.1 197 5 198 305 10.8 0 11.3 10.5 07/09/2005 17:20:00 8.1 0.8 9.9 5.7 7.8 0.8 9.5 5.7 198 6 200 305 10.5 0 10.8 10.2 07/09/2005 17:30:00 8.4 0.5 9.9 6.8 8.3 0.6 10.3 6.5 197 5 194 305 10.3 0 10.5 10.2 07/09/2005 17:40:00 8.7 0.7 10.7 6.1 8.6 0.8 10.7 6.1 193 5 196 305 10.4 0 10.8 10.2 07/09/2005 17:50:00 8.9 0.6 10.3 6.1 8.7 0.7 10.7 6.1 195 5 203 305 10.4 0 10.8 10.2 07/09/2005 18:00:00 8.7 0.6 10.7 6.8 8.5 0.7 10.3 6.1 196 5 198 305 10.2 0 10.5 10 07/09/2005 18:10:00 8.7 0.6 9.9 6.8 8.5 0.7 10.7 6.1 194 6 189 305 10.3 0 10.5 10 07/09/2005 18:20:00 8.7 0.8 10.7 6.5 8.5 0.9 10.3 6.1 194 6 193 305 10.2 0 10.2 10 07/09/2005 18:30:00 8.1 0.7 9.5 6.1 7.8 0.7 9.9 6.1 196 5 198 305 10.2 0 10.2 10 07/09/2005 18:40:00 8 0.7 9.9 5.7 7.6 0.7 9.5 5.7 197 6 198 305 10.2 0 10.2 10 07/09/2005 18:50:00 7.7 0.7 9.5 5.7 7.5 0.8 9.5 5.3 198 5 198 305 9.9 0 10.2 9.7 07/09/2005 19:00:00 7.9 0.6 9.5 6.5 7.7 0.7 9.5 6.1 200 6 202 305 9.9 0 10.2 9.7 07/09/2005 19:10:00 8.1 0.8 10.3 6.5 7.9 0.8 10.3 5.7 202 5 203 305 9.7 0 10.2 9.5 07/09/2005 19:20:00 7.8 0.5 9.5 6.1 7.6 0.6 9.1 5.7 200 5 208 305 9.7 0 10.2 9.5 07/09/2005 19:30:00 8.1 0.6 9.9 6.5 7.9 0.6 9.5 6.1 201 4 203 305 9.7 0 10.2 9.5 07/09/2005 19:40:00 8.3 0.6 9.9 6.8 8.1 0.6 9.5 6.1 197 5 200 305 9.5 0 10 9.5 07/09/2005 19:50:00 8.3 0.7 9.9 6.5 8.2 0.8 9.9 5.7 196 5 186 305 9.5 0 9.7 9.5 07/09/2005 20:00:00 8.6 0.7 10.3 6.5 8.3 0.8 10.3 6.5 197 5 201 305 9.5 0 9.7 9.5 07/09/2005 20:10:00 8.6 0.6 9.9 6.5 8.4 0.7 9.5 6.1 198 5 201 305 9.6 0 9.7 9.5 07/09/2005 20:20:00 9 0.5 10.7 7.6 8.7 0.7 10.3 6.5 198 5 208 305 9.3 0 9.7 9.2 07/09/2005 20:30:00 8.9 0.7 10.3 6.5 8.7 0.8 10.3 5.7 199 5 206 305 9.2 0 9.7 9.2 07/09/2005 20:40:00 8.9 0.6 10.7 7.2 8.7 0.7 10.7 6.5 199 5 205 305 9.2 0 9.2 9.2 07/09/2005 20:50:00 8.4 0.6 10.3 6.5 8.2 0.7 9.9 6.1 199 5 201 305 9.2 0 9.5 9.2 07/09/2005 21:00:00 8.6 0.6 10.3 6.8 8.5 0.7 10.3 6.5 196 4 197 305 9.2 0 9.2 9.2 07/09/2005 21:10:00 8.9 0.6 10.3 6.8 8.8 0.7 9.9 6.8 200 5 203 305 9.1 0 9.2 8.9 07/09/2005 21:20:00 8.4 0.5 9.9 6.8 8.3 0.6 9.5 6.5 203 5 208 305 8.9 0 9.2 8.9 07/09/2005 21:30:00 8.5 0.6 10.3 6.5 8.5 0.7 9.9 6.5 199 5 210 305 8.9 0 9.2 8.9 07/09/2005 21:40:00 8.7 0.6 10.3 6.8 8.8 0.7 10.7 6.1 192 6 198 305 9 0 9.2 8.9 07/09/2005 21:50:00 8.4 0.6 9.9 6.5 8.5 0.7 10.7 6.1 195 5 196 305 9.1 0 9.2 8.9 07/09/2005 22:00:00 9.1 0.6 11.1 7.6 9.1 0.6 10.7 7.2 198 5 204 305 8.9 0 9.2 8.9 07/09/2005 22:10:00 8.7 0.6 10.7 6.8 8.7 0.6 9.9 6.8 198 5 194 305 8.9 0 8.9 8.9 07/09/2005 22:20:00 9 0.6 10.3 6.5 8.9 0.6 10.7 6.8 197 5 196 305 8.9 0 9.2 8.9 07/09/2005 22:30:00 8.9 0.6 10.7 7.2 8.8 0.7 10.7 6.8 196 5 200 305 8.9 0 9.2 8.9 07/09/2005 22:40:00 9 0.6 10.3 7.2 8.9 0.7 10.7 6.8 196 5 193 305 8.9 0 9.2 8.9 07/09/2005 22:50:00 8.7 0.7 10.7 6.5 8.7 0.7 10.7 6.8 196 5 198 305 8.9 0 9.2 8.9 07/09/2005 23:00:00 9 0.6 10.7 7.6 8.9 0.7 10.7 6.1 199 4 205 305 8.9 0 9.2 8.9 07/09/2005 23:10:00 9.2 0.6 10.7 7.6 9.2 0.7 11.1 6.8 198 4 193 305 8.8 0 8.9 8.7 07/09/2005 23:20:00 9.1 0.5 10.7 7.6 9.2 0.6 11.1 6.8 202 4 208 305 8.8 0 8.9 8.7 07/09/2005 23:30:00 9.4 0.6 11.1 7.6 9.3 0.7 10.7 6.8 202 4 205 305 8.7 0 8.9 8.7 07/09/2005 23:40:00 8.7 0.6 10.3 7.2 8.7 0.6 10.7 6.8 205 4 201 305 8.7 0 8.9 8.7 07/09/2005 23:50:00 8.9 0.6 10.3 6.8 9 0.6 10.3 7.6 205 4 205 305 8.7 0 8.9 8.4 07/10/2005 00:00:00 9.5 0.6 11.5 8 9.5 0.6 11.1 7.6 203 4 207 305 8.7 0 9.2 8.4 07/10/2005 00:10:00 9.4 0.5 11.1 7.6 9.4 0.6 10.7 7.6 205 4 204 305 8.7 0 8.9 8.4 07/10/2005 00:20:00 9.4 0.6 11.5 7.6 9.4 0.6 10.7 7.6 205 4 210 305 8.6 0 8.9 8.4 07/10/2005 00:30:00 9.4 0.6 11.1 8 9.3 0.6 10.7 8 207 4 205 305 8.6 0 8.9 8.4 07/10/2005 00:40:00 9.1 0.6 10.7 7.6 9 0.6 10.3 7.2 207 5 214 305 8.6 0 8.9 8.4 07/10/2005 00:50:00 8.9 0.5 10.3 7.6 9 0.5 10.3 7.2 206 4 213 305 8.6 0 8.7 8.4 07/10/2005 01:00:00 9 0.6 10.7 7.6 9 0.7 10.7 6.8 206 4 205 305 8.6 0 8.7 8.4 07/10/2005 01:10:00 9.2 0.6 10.7 6.5 9.1 0.7 10.7 6.8 207 4 213 305 8.6 0 8.7 8.4 07/10/2005 01:20:00 9.7 0.6 11.5 8 9.5 0.7 11.5 7.6 206 4 210 305 8.6 0 8.7 8.4 07/10/2005 01:30:00 10 0.7 11.8 7.6 9.8 0.7 11.8 7.6 206 5 209 305 8.6 0 8.9 8.4 07/10/2005 01:40:00 9.2 0.8 11.1 6.5 8.8 0.9 10.7 6.1 210 6 210 305 8.6 0 8.9 8.4 07/10/2005 01:50:00 9.7 1 12.2 6.5 9.3 1.1 11.5 6.8 210 5 211 305 8.6 0 8.7 8.4 07/10/2005 02:00:00 10.1 0.8 12.2 7.6 9.7 1 12.2 6.8 211 6 211 305 8.6 0 8.9 8.4 07/10/2005 02:10:00 9.3 0.8 11.1 6.5 8.9 0.8 11.1 6.5 220 6 215 305 8.6 0 8.7 8.4 07/10/2005 02:20:00 9.8 0.8 11.8 6.8 9.3 0.9 11.1 6.8 219 6 210 305 8.6 0 8.7 8.4 07/10/2005 02:30:00 9.6 0.7 11.8 7.2 9.2 0.8 11.1 6.8 216 5 213 305 8.6 0 8.7 8.4 07/10/2005 02:40:00 9 0.7 11.1 6.8 8.8 0.7 10.7 6.1 219 5 218 305 8.6 0 8.7 8.4 07/10/2005 02:50:00 8.9 0.8 10.7 6.8 8.6 0.8 10.3 6.5 219 5 213 305 8.6 0 8.7 8.4 07/10/2005 03:00:00 8.9 0.7 11.1 6.1 8.3 0.8 10.7 6.1 222 5 217 305 8.6 0 8.7 8.4 07/10/2005 03:10:00 9.6 0.7 11.5 7.2 9 0.8 11.1 6.8 219 6 222 305 8.6 0 8.7 8.4 07/10/2005 03:20:00 9.5 0.9 11.5 6.8 8.9 1 11.1 6.5 223 6 223 305 8.6 0 8.9 8.4 07/10/2005 03:30:00 9.4 0.8 12.2 6.8 8.8 0.9 11.1 6.1 227 6 223 305 8.6 0 8.7 8.4 07/10/2005 03:40:00 9.3 0.8 11.1 6.5 8.8 1 10.7 6.1 229 6 229 305 8.6 0 8.9 8.4 07/10/2005 03:50:00 9 0.8 11.5 6.8 8.6 0.8 10.3 6.5 233 5 234 305 8.6 0 8.7 8.4 07/10/2005 04:00:00 8.8 0.7 11.1 6.8 8.1 0.8 9.9 6.1 227 6 233 305 8.6 0 8.7 8.4 07/10/2005 04:10:00 8.9 0.7 10.7 6.5 8.3 0.8 10.3 6.1 229 5 230 305 8.6 0 8.7 8.4 07/10/2005 04:20:00 8.8 0.6 10.3 6.8 8.2 0.7 9.5 5.3 230 5 232 305 8.6 0 8.7 8.4 07/10/2005 04:30:00 8.7 0.7 11.1 6.8 8.1 0.8 10.7 5.7 229 5 234 305 8.6 0 8.7 8.4 07/10/2005 04:40:00 8.9 0.7 11.1 6.8 8.1 0.8 10.3 6.1 227 6 229 305 8.6 0 8.7 8.4 07/10/2005 04:50:00 7.5 0.6 9.1 5.3 6.9 0.7 9.1 5.3 223 6 229 305 8.6 0 8.7 8.4 07/10/2005 05:00:00 7.1 0.7 9.1 5.3 6.8 0.8 8.8 4.6 215 7 220 305 8.6 0 8.7 8.4 07/10/2005 05:10:00 7 0.7 8.4 4.9 6.5 0.8 8.4 4.2 213 6 218 305 8.6 0 8.7 8.4 07/10/2005 05:20:00 8.2 0.8 9.9 6.1 8.3 0.9 10.7 5.7 202 6 197 305 8.6 0 8.9 8.4 07/10/2005 05:30:00 8.6 0.7 10.3 6.8 8.6 0.8 10.7 6.1 206 6 193 305 8.7 0 8.9 8.4 07/10/2005 05:40:00 7.6 0.8 9.5 5.3 7.3 0.9 9.1 4.9 212 6 216 305 8.6 0 8.7 8.4 07/10/2005 05:50:00 8.1 0.8 10.3 6.1 7.7 0.8 9.9 5.7 214 6 215 305 8.6 0 8.7 8.4 07/10/2005 06:00:00 8.6 0.9 10.7 4.9 8.2 1 10.7 5.7 212 6 211 305 8.5 0 8.7 8.4 07/10/2005 06:10:00 8.8 0.7 10.3 6.5 8.6 0.9 10.7 6.1 208 6 213 305 8.4 0 8.4 8.4 07/10/2005 06:20:00 9.1 0.5 10.3 7.6 9.1 0.5 10.7 7.2 205 4 210 305 8.4 0 8.4 8.2 07/10/2005 06:30:00 8.9 0.6 10.3 7.2 8.9 0.6 10.3 7.2 206 4 198 305 8.4 0 8.4 8.2 07/10/2005 06:40:00 8.1 0.7 9.5 5.3 7.7 0.8 9.1 5.3 211 5 215 305 8.3 0 8.4 8.2 07/10/2005 06:50:00 8.1 0.7 9.5 5.7 8 0.8 9.9 5.7 216 5 218 305 8.2 0 8.4 8.2 07/10/2005 07:00:00 8.1 0.7 9.9 5.7 7.7 0.8 9.9 5.3 213 5 217 305 8.3 0 8.4 8.2 07/10/2005 07:10:00 7.6 0.6 9.1 5.3 7.6 0.7 9.1 5.3 212 6 215 305 8.2 0 8.4 8.2 07/10/2005 07:20:00 7.5 0.7 9.1 5.3 7.1 0.8 9.1 4.9 213 6 210 305 8.3 0 8.4 8.2 07/10/2005 07:30:00 7.2 0.6 8.4 4.9 7 0.6 8.4 4.9 211 6 215 305 8.3 0 8.4 8.2 07/10/2005 07:40:00 7.4 0.7 9.1 5.7 7.2 0.8 8.8 4.6 213 6 210 305 8.3 0 8.4 8.2 07/10/2005 07:50:00 7.4 0.6 9.1 5.7 7.3 0.7 9.1 5.7 214 5 213 305 8.2 0 8.4 8.2 07/10/2005 08:00:00 7.5 0.7 9.1 4.6 7.3 0.8 9.1 4.6 213 5 212 305 8.2 0 8.4 8.2 07/10/2005 08:10:00 7.3 0.6 8.8 5.3 7.1 0.8 8.8 4.9 213 6 214 305 8.2 0 8.2 8.2 07/10/2005 08:20:00 7.3 0.7 9.1 4.6 7 0.7 8.8 4.9 213 6 220 305 8.2 0 8.2 8.2 07/10/2005 08:30:00 7.5 0.5 8.8 6.1 7.4 0.6 8.8 5.7 214 5 216 305 8.2 0 8.2 8.2 07/10/2005 08:40:00 7.5 0.5 8.8 6.1 7.3 0.6 8.8 5.7 215 4 205 305 8.1 0 8.2 7.9 07/10/2005 08:50:00 7.1 0.6 8.4 4.6 6.9 0.7 8.8 4.6 216 5 217 305 8.1 0 8.2 7.9 07/10/2005 09:00:00 6.7 0.5 7.6 5.3 6.2 0.7 7.6 4.2 215 6 222 305 8.1 0 8.2 7.9 07/10/2005 09:10:00 6.2 0.6 7.6 4.6 6 0.6 7.6 4.2 211 5 216 305 8.2 0 8.2 8.2 07/10/2005 09:20:00 6.7 0.6 8.4 4.6 6.3 0.8 8 4.2 212 5 219 305 8.2 0 8.4 8.2 07/10/2005 09:30:00 6.6 0.7 8.4 4.2 6.2 0.9 8.4 4.2 213 5 204 305 8.2 0 8.2 8.2 07/10/2005 09:40:00 6.6 0.5 8 4.6 6.4 0.8 8 4.2 211 6 205 305 8.2 0 8.2 8.2 07/10/2005 09:50:00 6.4 0.6 8 4.6 6.3 0.8 8 4.2 211 5 217 305 8.2 0 8.4 8.2 07/10/2005 10:00:00 6.6 0.6 8 4.6 6.4 0.7 8 4.9 212 6 215 305 8.3 0 8.4 8.2 07/10/2005 10:10:00 6.2 0.6 7.6 4.6 5.9 0.7 7.2 4.2 211 6 206 305 8.3 0 8.4 8.2 07/10/2005 10:20:00 6.4 0.6 7.6 4.6 6 0.7 7.6 4.2 211 6 215 305 8.3 0 8.4 8.2 07/10/2005 10:30:00 6.4 0.5 7.6 4.9 6.2 0.6 8 4.6 211 5 212 305 8.3 0 8.4 8.2 07/10/2005 10:40:00 6.3 0.6 7.6 4.2 6 0.6 7.6 4.2 210 6 213 305 8.3 0 8.4 8.2 07/10/2005 10:50:00 6.3 0.6 7.6 4.9 5.9 0.7 7.6 4.2 211 6 224 305 8.3 0 8.4 8.2 07/10/2005 11:00:00 6.5 0.6 8 4.6 6.2 0.7 7.6 4.6 210 6 216 305 8.2 0 8.4 8.2 07/10/2005 11:10:00 6.4 0.5 8 4.6 5.9 0.6 7.6 4.2 210 6 213 305 8.2 0 8.4 8.2 07/10/2005 11:20:00 6.5 0.6 8 4.6 6 0.8 7.6 3.4 211 5 207 305 8.2 0 8.4 8.2 07/10/2005 11:30:00 6.7 0.5 8 5.3 6.3 0.5 7.6 4.6 214 6 211 305 8.2 0 8.4 8.2 07/10/2005 11:40:00 6.2 0.5 7.6 4.6 5.9 0.5 7.2 4.2 219 5 211 305 8.1 0 8.2 7.9 07/10/2005 11:50:00 6.2 0.5 7.2 4.9 6 0.6 7.2 4.2 218 6 222 305 8.1 0 8.2 7.9 07/10/2005 12:00:00 6.3 0.6 7.6 4.6 5.6 0.7 7.2 3.8 223 6 226 305 8.1 0 8.2 8.2 07/10/2005 12:10:00 5.8 0.7 7.6 4.6 5.4 0.6 7.2 3.8 224 6 229 305 8.2 0 8.2 8.2 07/10/2005 12:20:00 5.9 0.7 7.2 3.8 5.4 0.7 6.8 3.8 226 6 221 305 8.1 0 8.2 7.9 07/10/2005 12:30:00 6.3 0.6 7.6 4.6 5.6 0.6 7.6 4.2 225 5 228 305 8.2 0 8.2 8.2 07/10/2005 12:40:00 6 0.5 7.2 4.6 5.5 0.7 7.2 3.8 223 6 229 305 8.2 0 8.2 8.2 07/10/2005 12:50:00 5.9 0.6 7.2 4.2 5.4 0.6 6.8 3.8 224 6 224 305 8.2 0 8.4 8.2 07/10/2005 13:00:00 5.8 0.6 7.2 3.8 5.2 0.6 6.8 3.8 223 6 225 305 8.2 0 8.4 8.2 07/10/2005 13:10:00 5.7 0.5 7.2 4.6 5.2 0.6 6.8 3.8 220 6 208 305 8.2 0 8.2 8.2 07/10/2005 13:20:00 5.8 0.5 6.8 4.6 5.4 0.5 6.5 4.2 216 6 221 305 8.2 0 8.4 8.2 07/10/2005 13:30:00 5.9 0.6 7.2 4.6 5.5 0.5 6.8 4.2 220 6 213 305 8.2 0 8.4 8.2 07/10/2005 13:40:00 6.2 0.6 7.6 4.6 5.7 0.6 7.2 4.2 220 6 213 305 8.2 0 8.4 8.2 07/10/2005 13:50:00 6.5 0.5 7.6 4.9 6 0.6 7.6 4.6 219 6 224 305 8.2 0 8.4 8.2 07/10/2005 14:00:00 6.1 0.6 7.6 4.2 5.7 0.6 7.2 4.2 221 6 224 305 8.2 0 8.4 8.2 07/10/2005 14:10:00 6.4 0.6 7.6 4.6 5.8 0.6 7.2 4.2 225 6 224 305 8.2 0 8.2 8.2 07/10/2005 14:20:00 6.1 0.6 7.6 4.2 5.5 0.6 7.2 4.2 224 6 227 305 8.2 0 8.2 8.2 07/10/2005 14:30:00 6 0.5 7.6 4.6 5.6 0.5 6.8 4.2 229 6 232 305 8.1 0 8.2 7.9 07/10/2005 14:40:00 5.7 0.5 6.8 4.6 5.1 0.5 6.8 3.4 223 6 221 305 8.2 0 8.2 8.2 07/10/2005 14:50:00 5.8 0.5 6.8 4.2 5.5 0.6 6.8 4.2 218 6 224 305 8.2 0 8.2 8.2 07/10/2005 15:00:00 6 0.5 7.6 4.6 5.6 0.6 7.2 4.2 218 6 228 305 8.2 0 8.2 8.2 07/10/2005 15:10:00 5.8 0.6 7.2 4.6 5.4 0.7 6.8 3.8 221 6 223 305 8.1 0 8.2 8.2 07/10/2005 15:20:00 5.7 0.5 7.2 4.6 5.5 0.5 6.8 4.2 219 6 214 305 8.1 0 8.2 8.2 07/10/2005 15:30:00 6 0.5 7.2 4.6 5.7 0.5 7.2 4.2 218 6 231 305 8.2 0 8.2 8.2 07/10/2005 15:40:00 5.8 0.5 6.8 4.2 5.6 0.5 6.8 4.2 217 6 225 305 8.2 0 8.2 7.9 07/10/2005 15:50:00 5.8 0.5 7.2 4.2 5.5 0.5 7.2 3.8 216 7 214 305 8.1 0 8.2 7.9 07/10/2005 16:00:00 6.7 0.6 8.4 4.2 6.5 0.7 8 4.6 201 6 199 305 8.1 0 8.2 7.9 07/10/2005 16:10:00 7.3 0.5 8.4 6.1 7.2 0.5 8.4 6.1 201 4 203 305 8.1 0 8.2 7.9 07/10/2005 16:20:00 6.8 0.6 8 4.9 6.6 0.7 8 4.6 207 5 205 305 8.1 0 8.2 7.9 07/10/2005 16:30:00 5.8 0.6 7.6 3.8 5.5 0.6 7.2 3.8 210 6 208 305 8 0 8.2 7.9 07/10/2005 16:40:00 5.8 0.4 6.8 4.6 5.7 0.4 6.8 4.2 205 5 209 305 8 0 8.2 7.9 07/10/2005 16:50:00 5.7 0.5 6.8 4.2 5.6 0.6 7.2 4.2 208 6 208 305 8 0 8.2 7.9 07/10/2005 17:00:00 6.2 0.4 7.2 4.9 6.1 0.4 7.2 4.6 205 5 205 305 8 0 8.2 7.9 07/10/2005 17:10:00 6 0.5 7.2 4.6 5.7 0.5 6.8 4.2 207 5 202 305 8 0 8.2 7.9 07/10/2005 17:20:00 6.1 0.5 7.6 4.9 6.1 0.5 7.6 4.2 203 5 211 305 8 0 8.2 7.9 07/10/2005 17:30:00 6.2 0.5 7.2 4.6 5.9 0.7 7.2 3.8 210 6 214 305 8 0 8.2 7.9 07/10/2005 17:40:00 6.4 0.6 7.6 4.6 6.2 0.6 7.6 4.6 208 5 207 305 8 0 8.2 7.9 07/10/2005 17:50:00 7.1 0.6 8.8 5.7 6.9 0.6 8.4 5.3 206 5 214 305 8 0 8.2 7.9 07/10/2005 18:00:00 6.9 0.7 8 4.9 6.6 0.8 8 4.6 211 6 209 305 8 0 8.2 7.9 07/10/2005 18:10:00 7.1 0.6 8.4 4.9 6.7 0.7 8.4 4.9 210 5 215 305 8 0 8.2 7.9 07/10/2005 18:20:00 6.8 0.6 8 4.6 6.7 0.6 8 4.9 208 5 204 305 8 0 8.2 7.9 07/10/2005 18:30:00 6.9 0.7 8.4 4.6 6.3 0.8 8.4 4.2 211 5 211 305 7.9 0 7.9 7.9 07/10/2005 18:40:00 7.5 0.6 8.8 5.3 7 0.7 8.8 4.9 211 5 212 305 7.9 0 7.9 7.7 07/10/2005 18:50:00 7.5 0.6 8.8 5.3 6.9 0.7 8.4 4.9 211 6 204 305 7.9 0 7.9 7.7 07/10/2005 19:00:00 7.8 0.6 9.1 5.7 7.3 0.8 8.8 5.3 213 5 216 305 7.9 0 7.9 7.7 07/10/2005 19:10:00 8.5 0.6 9.9 6.5 8 0.7 9.9 6.1 212 5 211 305 7.8 0 7.9 7.7 07/10/2005 19:20:00 8.8 0.5 9.9 6.8 8.2 0.7 9.9 6.1 213 5 212 305 7.8 0 7.9 7.7 07/10/2005 19:30:00 8.4 0.5 9.5 6.5 7.8 0.6 9.1 5.7 216 4 222 305 7.7 0 7.9 7.7 07/10/2005 19:40:00 8.3 0.5 9.5 6.8 7.8 0.6 9.1 5.7 215 4 214 305 7.7 0 7.9 7.7 07/10/2005 19:50:00 8.5 0.5 9.5 6.5 8 0.6 9.1 5.7 215 4 213 305 7.7 0 7.9 7.7 07/10/2005 20:00:00 8.3 0.5 9.1 6.1 7.8 0.6 9.1 5.7 215 4 214 305 7.7 0 7.9 7.7 07/10/2005 20:10:00 8.4 0.5 9.5 7.2 8 0.6 9.5 6.1 216 4 217 305 7.7 0 7.9 7.7 07/10/2005 20:20:00 8.7 0.5 9.9 7.6 8.3 0.6 9.5 6.1 215 4 214 305 7.7 0 7.9 7.7 07/10/2005 20:30:00 8.4 0.6 9.5 6.1 7.8 0.7 9.5 5.7 219 6 214 305 7.7 0 7.9 7.7 07/10/2005 20:40:00 8.4 0.5 9.5 6.5 7.8 0.7 9.1 5.7 216 6 213 305 7.7 0 7.7 7.7 07/10/2005 20:50:00 8.1 0.6 9.5 6.1 7.5 0.6 9.1 5.7 218 5 209 305 7.7 0 7.9 7.7 07/10/2005 21:00:00 8.1 0.6 9.1 6.1 7.5 0.7 8.8 5.3 212 6 219 305 7.7 0 7.9 7.7 07/10/2005 21:10:00 7.9 0.7 9.1 5.7 7.5 0.8 9.1 5.3 212 5 208 305 7.7 0 7.9 7.7 07/10/2005 21:20:00 8 0.6 9.5 6.1 7.5 0.8 9.1 4.9 216 5 213 305 7.7 0 7.9 7.7 07/10/2005 21:30:00 7 0.6 8.4 4.9 6.6 0.6 8.4 4.9 219 5 215 305 7.7 0 7.9 7.7 07/10/2005 21:40:00 7.3 0.6 8.8 5.3 6.9 0.6 8.4 5.3 218 4 214 305 7.7 0 7.7 7.7 07/10/2005 21:50:00 8 0.6 9.1 6.5 7.6 0.6 8.8 5.7 214 6 221 305 7.7 0 7.7 7.7 07/10/2005 22:00:00 8.1 0.6 9.9 6.5 7.6 0.7 9.1 4.9 211 5 206 305 7.7 0 7.9 7.7 07/10/2005 22:10:00 7.8 0.7 9.1 5.3 7.3 0.8 9.1 5.3 210 6 207 305 7.7 0 7.9 7.7 07/10/2005 22:20:00 7.7 0.6 9.1 4.9 7.2 0.7 8.8 4.9 211 5 214 305 7.7 0 7.9 7.7 07/10/2005 22:30:00 7.5 0.5 8.8 6.1 7.1 0.7 8.4 4.9 215 4 214 305 7.7 0 7.9 7.7 07/10/2005 22:40:00 7.7 0.5 9.1 6.5 7.3 0.6 8.8 5.7 213 3 212 305 7.7 0 7.9 7.7 07/10/2005 22:50:00 7.5 0.6 8.8 5.7 7 0.7 8.4 4.9 212 5 206 305 7.8 0 7.9 7.7 07/10/2005 23:00:00 7 0.5 8.4 5.7 6.6 0.6 8 4.9 213 5 213 305 7.8 0 7.9 7.7 07/10/2005 23:10:00 6.9 0.5 8 4.9 6.6 0.6 8 4.6 213 5 208 305 7.8 0 7.9 7.7 07/10/2005 23:20:00 6.9 0.5 8 5.3 6.6 0.6 7.6 4.6 214 5 213 305 7.7 0 7.9 7.7 07/10/2005 23:30:00 6.6 0.5 8.4 4.9 6.3 0.6 7.6 4.9 217 5 217 305 7.7 0 7.9 7.7 07/10/2005 23:40:00 6.5 0.5 7.6 4.9 6.1 0.5 7.2 4.9 215 4 214 305 7.7 0 7.9 7.7 07/10/2005 23:50:00 5.8 0.7 7.2 3.4 5.5 0.7 7.2 3.4 213 6 220 305 7.7 0 7.9 7.7 07/11/2005 00:00:00 5.7 0.6 6.8 4.2 5.4 0.6 6.5 3.8 212 5 214 305 7.7 0 8.4 7.7 07/11/2005 00:10:00 5.2 0.5 6.1 3.8 5 0.5 6.1 3.8 215 5 214 305 7.7 0 7.9 7.7 07/11/2005 00:20:00 5.2 0.5 6.8 3.4 4.9 0.6 6.1 3.4 210 6 209 305 7.7 0 7.9 7.7 07/11/2005 00:30:00 5.7 0.5 6.8 4.2 5.3 0.6 6.5 3.4 209 5 208 305 7.7 0 7.9 7.7 07/11/2005 00:40:00 5.7 0.6 7.2 4.2 5.5 0.6 6.5 3.8 210 5 208 305 7.8 0 7.9 7.7 07/11/2005 00:50:00 6 0.5 7.2 4.2 5.8 0.6 6.8 4.2 209 5 208 305 7.8 0 7.9 7.7 07/11/2005 01:00:00 5.7 0.6 7.2 3.8 5.3 0.6 6.8 3.8 210 6 215 305 7.8 0 7.9 7.7 07/11/2005 01:10:00 6.2 0.7 7.6 3.8 5.8 0.7 7.2 4.2 210 5 211 305 7.7 0 7.9 7.7 07/11/2005 01:20:00 6.2 0.6 7.6 4.2 5.8 0.7 7.2 4.2 210 6 214 305 7.7 0 7.9 7.7 07/11/2005 01:30:00 6.6 0.6 8.4 4.6 6.5 0.6 8 4.6 206 5 208 305 7.8 0 7.9 7.7 07/11/2005 01:40:00 7.2 0.5 8.4 4.9 6.9 0.6 8 4.6 207 5 210 305 7.8 0 7.9 7.7 07/11/2005 01:50:00 7 0.6 8.4 4.6 6.6 0.7 8.4 4.6 208 5 213 305 7.8 0 7.9 7.7 07/11/2005 02:00:00 7.4 0.5 8.8 5.3 6.9 0.6 8.4 4.9 211 5 209 305 7.8 0 7.9 7.7 07/11/2005 02:10:00 7.1 0.6 8.4 4.9 6.7 0.7 8.4 4.9 212 5 225 305 7.8 0 7.9 7.7 07/11/2005 02:20:00 7.5 0.6 9.1 5.7 7.2 0.7 9.1 5.3 217 6 222 305 7.7 0 7.9 7.7 07/11/2005 02:30:00 8.1 0.6 9.5 6.1 7.3 0.7 9.5 5.7 225 5 224 305 7.7 0 7.9 7.7 07/11/2005 02:40:00 8.3 0.7 9.9 6.5 7.6 0.8 9.5 5.3 226 5 225 305 7.7 0 7.7 7.7 07/11/2005 02:50:00 8.1 0.6 9.9 5.7 7.6 0.6 9.1 6.1 227 5 222 305 7.6 0 7.7 7.7 07/11/2005 03:00:00 8 0.5 9.1 6.5 7.6 0.6 9.1 6.1 228 5 225 305 7.6 0 7.7 7.7 07/11/2005 03:10:00 8.2 0.6 9.9 6.8 7.6 0.7 9.5 5.7 228 5 231 305 7.6 0 7.7 7.7 07/11/2005 03:20:00 8.3 0.7 9.9 6.5 7.7 0.8 9.5 5.7 226 5 224 305 7.6 0 7.7 7.7 07/11/2005 03:30:00 8.5 0.6 9.9 6.8 7.9 0.7 9.5 5.7 227 5 224 305 7.6 0 7.7 7.7 07/11/2005 03:40:00 8.5 0.6 9.9 6.1 7.9 0.7 9.5 5.3 228 5 231 305 7.6 0 7.7 7.7 07/11/2005 03:50:00 8.3 0.5 9.5 6.5 7.5 0.7 9.5 5.7 227 5 223 305 7.5 0 7.7 7.7 07/11/2005 04:00:00 8.3 0.6 9.9 6.5 7.7 0.6 9.1 5.7 229 4 230 305 7.5 0 7.7 7.4 07/11/2005 04:10:00 7.9 0.6 9.1 6.1 7.4 0.6 8.8 5.3 229 5 229 305 7.5 0 7.7 7.4 07/11/2005 04:20:00 7.5 0.5 8.8 6.1 7.1 0.6 8.8 5.3 229 5 227 305 7.5 0 7.7 7.7 07/11/2005 04:30:00 7.2 0.5 8.4 5.7 6.5 0.6 7.6 4.6 227 5 224 305 7.6 0 7.7 7.7 07/11/2005 04:40:00 7.4 0.5 8.4 5.3 6.7 0.6 8 4.9 228 5 228 305 7.6 0 7.7 7.7 07/11/2005 04:50:00 7.2 0.6 8.4 5.3 6.6 0.7 8.4 4.9 226 5 232 305 7.5 0 7.7 7.7 07/11/2005 05:00:00 7.2 0.6 8.4 5.3 6.6 0.7 8 4.2 227 5 221 305 7.5 0 7.7 7.4 07/11/2005 05:10:00 7.3 0.5 8.8 5.7 6.8 0.6 8.4 4.9 229 4 232 305 7.5 0 7.7 7.4 07/11/2005 05:20:00 7.3 0.7 9.5 5.7 6.7 0.8 8.8 4.9 233 5 233 305 7.5 0 7.7 7.4 07/11/2005 05:30:00 6.8 0.6 8 4.9 6.2 0.6 7.6 4.6 233 5 242 305 7.5 0 7.7 7.4 07/11/2005 05:40:00 7 0.7 8.8 4.9 6.3 0.7 8 3.8 236 6 236 305 7.5 0 7.7 7.4 07/11/2005 05:50:00 7.1 0.7 8.8 5.7 6.4 0.6 8 4.9 238 5 232 305 7.5 0 7.7 7.4 07/11/2005 06:00:00 6.8 0.7 8.4 5.3 6.2 0.8 8 4.2 236 6 233 305 7.5 0 7.7 7.4 07/11/2005 06:10:00 6.8 0.8 9.1 4.9 6 0.9 8.4 3.8 237 5 241 305 7.5 0 7.7 7.4 07/11/2005 06:20:00 6.7 0.7 8.4 4.9 6 0.7 8.4 3.8 236 5 236 305 7.5 0 7.7 7.4 07/11/2005 06:30:00 7 0.7 8.8 4.9 6.1 0.7 8 4.6 238 5 239 305 7.5 0 7.7 7.4 07/11/2005 06:40:00 6.6 0.7 8.4 4.6 5.7 0.8 7.6 3.8 238 6 241 305 7.5 0 7.7 7.4 07/11/2005 06:50:00 6.7 0.6 8 4.6 5.8 0.7 7.6 3.8 239 5 245 305 7.5 0 7.7 7.4 07/11/2005 07:00:00 6.6 0.7 8.4 4.9 5.7 0.7 7.6 4.2 238 6 238 305 7.5 0 7.7 7.4 07/11/2005 07:10:00 6.8 0.7 8 4.9 5.8 0.7 7.6 4.2 237 5 240 305 7.5 0 7.7 7.4 07/11/2005 07:20:00 6.2 0.6 7.6 4.2 5.4 0.6 6.8 3.8 236 5 239 305 7.5 0 7.7 7.4 07/11/2005 07:30:00 6.7 0.7 8.4 4.6 5.8 0.8 7.6 3.8 238 5 238 305 7.5 0 7.7 7.4 07/11/2005 07:40:00 6.9 0.6 8 4.9 6 0.6 7.6 4.2 240 5 230 305 7.5 0 7.7 7.4 07/11/2005 07:50:00 6.2 0.6 8 4.6 5.3 0.7 6.8 3 242 6 236 305 7.5 0 7.7 7.4 07/11/2005 08:00:00 6.7 0.5 8 4.9 5.8 0.7 7.2 3.8 244 5 245 305 7.5 0 7.7 7.4 07/11/2005 08:10:00 4 1.1 7.6 2.3 3.9 1 6.8 2.6 292 26 234 305 7 0.2 7.7 6.7 07/11/2005 08:20:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 302 18 299 305 6.6 0 6.9 6.4 07/11/2005 08:30:00 2 0.4 3 1.1 2.1 0.4 3 1.1 291 9 296 305 6.7 0 6.9 6.4 07/11/2005 08:40:00 2.2 0.4 3 1.1 2.2 0.4 3 1.1 279 7 284 305 6.6 0 6.9 6.4 07/11/2005 08:50:00 2.3 0.5 3.4 0.7 2 0.4 2.6 1.1 271 8 264 305 6.5 0 6.7 6.4 07/11/2005 09:00:00 2.3 0.4 3 1.5 2.1 0.4 3 1.1 273 8 273 305 6.5 0 6.7 6.4 07/11/2005 09:10:00 2.8 0.4 3.8 1.9 2.5 0.4 3.4 1.5 277 6 276 305 6.5 0 6.7 6.4 07/11/2005 09:20:00 2.5 0.4 3.4 1.5 2 0.4 3 1.1 266 7 273 305 6.5 0 6.7 6.4 07/11/2005 09:30:00 2.6 0.5 3.8 1.1 2.1 0.4 3.4 1.1 269 9 275 305 6.5 0 6.7 6.4 07/11/2005 09:40:00 2.8 0.5 3.8 1.1 2.3 0.5 3.4 0.7 271 7 283 305 6.5 0 6.7 6.1 07/11/2005 09:50:00 2.5 0.4 3.4 1.5 2.1 0.4 3 1.1 264 8 256 305 6.5 0 6.7 6.4 07/11/2005 10:00:00 2.5 0.5 3.4 1.5 2.1 0.4 3 1.1 260 7 259 305 6.5 0 6.7 6.4 07/11/2005 10:10:00 2.5 0.7 3.8 1.1 2.1 0.5 3 1.1 266 7 275 305 6.5 0 6.7 6.4 07/11/2005 10:20:00 2 0.5 3.4 0.4 1.9 0.4 3 0.7 263 8 262 305 6.5 0 6.7 6.4 07/11/2005 10:30:00 2.1 0.6 3 0.7 2 0.5 3 0.7 258 8 251 305 6.5 0 6.7 6.4 07/11/2005 10:40:00 2.3 0.3 3 1.1 2.2 0.3 3 1.1 255 6 261 305 6.5 0 6.7 6.4 07/11/2005 10:50:00 1.5 0.4 2.3 0.4 1.5 0.4 2.3 0.7 254 6 254 305 6.5 0 6.7 6.4 07/11/2005 11:00:00 2 0.5 3 0.7 2.1 0.5 3 0.7 238 10 223 305 6.5 0 6.7 6.4 07/11/2005 11:10:00 2.4 0.3 3.4 1.5 2.6 0.3 3.4 1.9 228 6 224 305 6.5 0 6.7 6.4 07/11/2005 11:20:00 2.2 0.4 3 1.1 2.3 0.4 3 1.1 236 7 233 305 6.5 0 6.7 6.4 07/11/2005 11:30:00 1.9 0.3 2.6 0.7 2.1 0.3 2.6 1.5 235 6 232 305 6.6 0 6.7 6.4 07/11/2005 11:40:00 2 0.4 2.6 1.1 2.1 0.4 2.6 1.1 236 6 235 305 6.5 0 6.7 6.4 07/11/2005 11:50:00 1.5 0.3 2.3 0.7 1.7 0.3 2.3 0.4 242 8 245 305 6.5 0 6.7 6.4 07/11/2005 12:00:00 1 0.4 1.9 0.4 1.2 0.3 1.9 0.4 236 8 223 305 6.5 0 6.7 6.4 07/11/2005 12:10:00 1 0.4 2.3 0.4 1.3 0.4 2.3 0.4 219 8 224 305 6.6 0 6.9 6.4 07/11/2005 12:20:00 1.2 0.3 1.9 0.4 1.4 0.4 1.9 0.4 210 7 214 305 6.7 0 6.9 6.4 07/11/2005 12:30:00 1.1 0.4 1.9 0.4 1.4 0.4 2.3 0.4 206 7 210 305 6.8 0 6.9 6.7 07/11/2005 12:40:00 1.1 0.5 2.3 0.4 1.4 0.5 2.3 0.4 201 8 208 305 6.9 0 7.2 6.7 07/11/2005 12:50:00 0.7 0.4 1.9 0.4 1 0.5 2.3 0.4 195 13 194 305 7 0 7.2 6.9 07/11/2005 13:00:00 0.4 0.2 1.1 0.4 0.7 0.4 1.5 0.4 189 15 187 305 7 0 7.2 6.9 07/11/2005 13:10:00 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 201 5 200 305 7 0 7.2 6.9 07/11/2005 13:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 83 94 305 305 7 0 7.2 6.9 07/11/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 43 1 305 305 6.8 0 7.2 6.7 07/11/2005 13:40:00 0.8 0.7 2.6 0.4 0.8 0.7 3 0.4 122 66 189 305 7.1 0.1 7.4 6.9 07/11/2005 13:50:00 2.7 0.5 3.8 1.1 2.8 0.5 3.8 1.5 193 7 194 305 7.5 0 7.7 7.4 07/11/2005 14:00:00 2 0.7 3.8 0.4 2.5 0.6 3.8 1.1 188 9 197 305 7.7 0 7.9 7.7 07/11/2005 14:10:00 0.9 0.5 2.3 0.4 1.1 0.6 2.3 0.4 207 24 208 305 7.6 0 7.9 7.4 07/11/2005 14:20:00 1.1 0.8 3 0.4 1.4 0.8 3.4 0.4 132 72 111 305 7.3 0 7.7 7.2 07/11/2005 14:30:00 2.3 0.7 3.8 0.7 2.7 0.7 4.2 1.1 38 10 34 305 6.8 0 7.2 6.7 07/11/2005 14:40:00 2.6 0.7 4.2 0.7 3.1 0.6 4.6 1.9 37 10 42 305 6.7 0 6.9 6.4 07/11/2005 14:50:00 4.3 0.5 5.3 3 4.3 0.5 5.7 2.6 47 8 45 305 6.6 0 6.9 6.4 07/11/2005 15:00:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.8 53 4 51 305 6.7 0 6.9 6.4 07/11/2005 15:10:00 4.9 0.6 6.5 3.8 4.8 0.6 6.5 3.4 56 6 58 305 6.7 0 6.9 6.4 07/11/2005 15:20:00 5.9 0.3 6.5 4.9 5.8 0.4 6.8 4.6 53 3 57 305 6.5 0 6.9 6.4 07/11/2005 15:30:00 5.9 0.4 6.8 4.6 5.8 0.4 6.8 4.6 54 3 55 305 6.4 0 6.7 6.1 07/11/2005 15:40:00 5.7 0.5 6.5 4.2 5.6 0.5 6.5 4.2 53 3 53 305 6.4 0 6.4 6.1 07/11/2005 15:50:00 5.3 0.3 6.1 4.2 5.2 0.4 6.1 3.8 54 3 58 305 6.3 0 6.4 6.1 07/11/2005 16:00:00 4.9 0.3 5.7 4.2 4.8 0.4 5.3 3.8 53 3 51 305 6.3 0 6.4 6.1 07/11/2005 16:10:00 5.1 0.2 5.7 4.6 5 0.3 5.7 4.2 51 4 52 305 6.2 0 6.4 6.1 07/11/2005 16:20:00 5 0.3 5.7 4.2 4.9 0.4 5.7 3.8 52 4 51 305 6.1 0 6.4 5.9 07/11/2005 16:30:00 5.5 0.4 6.1 4.2 5.4 0.4 6.1 4.2 49 3 50 305 6.1 0 6.4 5.9 07/11/2005 16:40:00 5.9 0.4 6.5 4.9 5.8 0.4 6.8 4.6 49 3 48 305 6.1 0 6.4 5.9 07/11/2005 16:50:00 5.8 0.4 6.5 4.9 5.7 0.4 6.5 4.6 46 3 45 305 6 0 6.1 5.9 07/11/2005 17:00:00 5.3 0.4 6.1 4.2 5.3 0.4 6.1 4.2 50 5 41 305 6.1 0 6.4 5.9 07/11/2005 17:10:00 4.8 0.2 5.3 3.8 4.7 0.2 5.3 4.2 56 3 60 305 6.1 0.1 6.4 5.9 07/11/2005 17:20:00 5.2 0.2 5.7 4.6 5.1 0.3 5.7 4.2 50 2 48 305 6.1 0 6.1 5.9 07/11/2005 17:30:00 5.1 0.2 5.7 4.6 5.1 0.3 5.7 4.2 50 2 56 305 6.1 0 6.4 5.9 07/11/2005 17:40:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 3.8 49 3 48 305 6.1 0 6.4 5.9 07/11/2005 17:50:00 4.8 0.3 5.3 3.8 4.7 0.3 5.3 3.8 46 3 42 305 6.1 0 6.4 5.9 07/11/2005 18:00:00 4.6 0.2 4.9 3.8 4.6 0.3 4.9 3.8 49 3 48 305 6.1 0.1 6.4 5.9 07/11/2005 18:10:00 4.8 0.2 5.3 4.2 4.8 0.3 5.3 3.8 46 3 48 305 6 0 6.4 5.9 07/11/2005 18:20:00 4.7 0.2 5.3 3.8 4.7 0.3 5.3 3.8 49 3 48 305 6.1 0 6.4 5.9 07/11/2005 18:30:00 4.7 0.2 5.3 3.8 4.7 0.3 5.3 3.8 44 2 47 305 6.2 0 6.4 6.1 07/11/2005 18:40:00 4.8 0.2 5.3 4.2 4.8 0.3 5.3 3.8 37 3 43 305 6.2 0 6.4 5.9 07/11/2005 18:50:00 4.6 0.3 5.3 3.8 4.5 0.4 5.3 3.4 38 3 45 305 6.2 0 6.4 5.9 07/11/2005 19:00:00 4.3 0.3 4.9 3.4 4.3 0.3 4.9 3.4 42 3 47 305 6.2 0.1 6.4 5.9 07/11/2005 19:10:00 4.5 0.2 4.9 3.8 4.5 0.2 4.9 3.8 41 3 41 305 6.1 0 6.4 5.9 07/11/2005 19:20:00 4.5 0.2 5.3 3.8 4.4 0.3 4.9 3.4 45 3 44 305 6.2 0 6.4 5.9 07/11/2005 19:30:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.4 42 2 43 305 6.3 0 6.4 6.1 07/11/2005 19:40:00 4.8 0.2 5.3 4.2 4.9 0.3 5.3 4.2 41 3 44 305 6.4 0 6.4 6.1 07/11/2005 19:50:00 5.2 0.2 5.7 4.6 4.9 0.3 5.7 3.8 39 3 41 305 6.5 0 6.7 6.1 07/11/2005 20:00:00 5.1 0.3 5.7 4.6 5 0.4 5.7 3.8 36 4 36 305 6.5 0 6.9 6.4 07/11/2005 20:10:00 5.3 0.3 6.1 4.6 5.3 0.3 6.1 4.6 35 3 33 305 6.3 0 6.4 6.1 07/11/2005 20:20:00 5.5 0.2 6.1 4.9 5.5 0.3 6.1 4.2 38 3 38 305 6.3 0 6.4 6.1 07/11/2005 20:30:00 5.4 0.3 6.1 4.6 5.4 0.3 6.1 4.2 37 3 42 305 6.2 0 6.4 6.1 07/11/2005 20:40:00 5.3 0.3 5.7 4.6 5.3 0.3 6.1 4.6 35 4 38 305 6.1 0 6.4 5.9 07/11/2005 20:50:00 5.3 0.3 6.1 4.2 5.2 0.3 6.1 4.6 41 3 44 305 6 0 6.1 5.9 07/11/2005 21:00:00 5.5 0.4 6.5 4.2 5.4 0.4 6.1 4.2 48 3 48 305 6 0 6.1 5.9 07/11/2005 21:10:00 5.8 0.3 6.5 4.9 5.7 0.4 6.5 4.9 51 3 48 305 6 0 6.1 5.9 07/11/2005 21:20:00 6.1 0.4 6.8 5.3 6 0.4 7.2 4.9 45 4 42 305 5.9 0 6.1 5.9 07/11/2005 21:30:00 6.1 0.4 6.8 4.9 6 0.4 6.8 4.9 44 3 44 305 5.8 0 5.9 5.6 07/11/2005 21:40:00 6.5 0.4 7.2 5.3 6.4 0.4 7.2 5.3 41 3 40 305 5.8 0 5.9 5.6 07/11/2005 21:50:00 6.3 0.4 7.2 4.9 6.2 0.5 7.2 4.9 46 5 53 305 5.8 0 5.9 5.6 07/11/2005 22:00:00 6.8 0.5 7.6 5.3 6.7 0.6 7.6 5.3 48 4 49 305 5.7 0 5.9 5.6 07/11/2005 22:10:00 6.9 0.5 8 5.3 6.7 0.6 8 5.3 45 4 52 305 5.7 0 5.9 5.6 07/11/2005 22:20:00 7.1 0.6 8 5.7 6.9 0.6 8 5.7 44 4 42 305 5.6 0 5.9 5.4 07/11/2005 22:30:00 7.2 0.4 8 5.7 7.1 0.5 8 5.7 43 4 42 305 5.5 0 5.9 5.4 07/11/2005 22:40:00 7.1 0.5 8 6.1 7 0.6 8 5.7 42 3 39 305 5.5 0 5.6 5.4 07/11/2005 22:50:00 7.2 0.4 8 5.7 7 0.5 8 5.7 44 3 41 305 5.5 0 5.6 5.4 07/11/2005 23:00:00 7.4 0.5 8.4 6.1 7.3 0.5 8.4 5.7 40 3 36 305 5.5 0 5.9 5.4 07/11/2005 23:10:00 7 0.5 8.4 5.7 6.9 0.5 8 5.3 42 4 42 305 5.6 0.1 5.9 5.4 07/11/2005 23:20:00 7.5 0.5 8.8 6.1 7.4 0.5 8.4 5.7 38 3 35 305 5.6 0.1 5.9 5.4 07/11/2005 23:30:00 7.9 0.4 9.1 6.5 7.8 0.5 9.1 6.5 37 4 39 305 5.6 0 5.9 5.4 07/11/2005 23:40:00 8.1 0.5 9.1 6.5 8 0.5 9.1 6.5 37 3 41 305 5.6 0.1 5.9 5.4 07/11/2005 23:50:00 7.9 0.5 8.8 6.5 7.7 0.5 9.1 6.1 41 4 42 305 5.6 0.1 5.9 5.4 07/12/2005 00:00:00 8.2 0.5 9.1 6.8 8.1 0.5 9.1 6.1 42 4 42 305 5.5 0 5.9 5.4 07/12/2005 00:10:00 8.1 0.5 9.1 6.5 7.9 0.6 9.1 6.1 44 3 46 305 5.6 0 5.9 5.4 07/12/2005 00:20:00 8.1 0.5 9.1 6.8 7.9 0.6 9.1 6.5 43 3 43 305 5.6 0 5.9 5.4 07/12/2005 00:30:00 8.4 0.5 9.5 6.5 8.2 0.6 9.1 6.1 42 3 43 305 5.6 0 5.9 5.4 07/12/2005 00:40:00 8.4 0.5 9.5 7.2 8.2 0.5 9.5 6.5 40 3 42 305 5.6 0 5.9 5.4 07/12/2005 00:50:00 8.6 0.5 9.5 7.2 8.5 0.5 9.5 7.2 43 4 39 305 5.6 0 5.9 5.4 07/12/2005 01:00:00 8.6 0.5 9.5 7.2 8.5 0.5 9.5 6.8 43 4 41 305 5.6 0 5.9 5.4 07/12/2005 01:10:00 8.5 0.5 9.5 6.8 8.4 0.6 9.5 6.8 41 3 36 305 5.5 0.1 5.9 5.4 07/12/2005 01:20:00 8.2 0.6 9.5 6.5 8.1 0.6 9.1 6.8 42 4 48 305 5.6 0 5.9 5.4 07/12/2005 01:30:00 8.7 0.5 9.9 6.8 8.6 0.5 9.5 6.5 39 3 37 305 5.6 0 5.9 5.4 07/12/2005 01:40:00 8.4 0.6 9.9 6.8 8.4 0.7 9.5 6.8 40 3 37 305 5.6 0.1 5.9 5.4 07/12/2005 01:50:00 8.9 0.5 9.9 7.6 8.8 0.6 9.9 7.6 38 3 37 305 5.5 0 5.9 5.4 07/12/2005 02:00:00 8.9 0.5 9.9 7.2 8.8 0.6 9.9 6.8 42 4 36 305 5.4 0 5.6 5.4 07/12/2005 02:10:00 8.9 0.5 9.9 7.6 8.8 0.5 9.5 6.8 44 3 38 305 5.5 0 5.6 5.4 07/12/2005 02:20:00 8.8 0.6 9.9 7.2 8.6 0.6 9.9 6.8 44 3 45 305 5.5 0 5.9 5.4 07/12/2005 02:30:00 9 0.5 9.9 7.2 8.8 0.6 9.9 6.8 44 3 46 305 5.5 0 5.9 5.4 07/12/2005 02:40:00 8.7 0.4 9.5 7.2 8.6 0.5 9.5 7.2 44 3 41 305 5.5 0 5.6 5.4 07/12/2005 02:50:00 8.8 0.6 9.9 6.5 8.5 0.7 9.9 6.8 46 4 44 305 5.4 0 5.6 5.4 07/12/2005 03:00:00 8.4 0.5 9.1 6.8 8.2 0.6 9.5 6.5 45 3 46 305 5.4 0 5.6 5.4 07/12/2005 03:10:00 8.2 0.4 9.1 7.2 8 0.4 9.1 6.8 48 4 47 305 5.4 0 5.6 5.4 07/12/2005 03:20:00 7.8 0.7 9.1 5.7 7.7 0.7 9.1 5.7 47 4 42 305 5.5 0 5.9 5.4 07/12/2005 03:30:00 8.3 0.5 9.1 6.8 8.2 0.5 9.1 6.5 43 3 44 305 5.5 0 5.9 5.4 07/12/2005 03:40:00 8.6 0.5 9.5 7.6 8.4 0.5 9.5 7.2 42 4 40 305 5.4 0 5.6 5.4 07/12/2005 03:50:00 8.8 0.6 9.9 7.2 8.7 0.6 9.9 6.8 44 3 46 305 5.4 0 5.6 5.4 07/12/2005 04:00:00 8.3 0.6 9.5 6.8 8.2 0.7 9.5 6.5 44 5 46 305 5.4 0 5.6 5.4 07/12/2005 04:10:00 8.5 0.5 9.5 7.2 8.4 0.5 9.5 7.2 42 4 40 305 5.3 0 5.6 5.2 07/12/2005 04:20:00 8.8 0.5 9.5 7.2 8.7 0.6 9.9 6.5 43 4 43 305 5.3 0 5.6 5.2 07/12/2005 04:30:00 8.5 0.6 9.9 6.8 8.3 0.7 9.9 6.1 44 4 45 305 5.3 0 5.6 5.2 07/12/2005 04:40:00 8.9 0.5 9.9 6.8 8.7 0.6 9.9 6.5 46 3 45 305 5.3 0 5.6 5.2 07/12/2005 04:50:00 8.7 0.5 9.9 7.6 8.6 0.5 9.5 7.2 42 4 42 305 5.3 0 5.6 5.2 07/12/2005 05:00:00 8.5 0.5 9.5 7.2 8.4 0.5 9.1 6.8 43 3 45 305 5.3 0 5.6 5.2 07/12/2005 05:10:00 8 0.6 9.1 6.5 7.8 0.7 9.1 6.1 44 4 40 305 5.3 0 5.6 5.2 07/12/2005 05:20:00 7.9 0.5 8.8 6.5 7.7 0.5 8.8 6.1 43 3 42 305 5.3 0 5.6 5.2 07/12/2005 05:30:00 8.2 0.5 9.1 6.8 8 0.6 9.1 6.5 41 3 35 305 5.3 0 5.6 5.2 07/12/2005 05:40:00 8.1 0.5 9.1 6.5 8 0.6 9.1 6.5 40 3 40 305 5.3 0 5.6 5.2 07/12/2005 05:50:00 8.2 0.5 9.1 6.5 8 0.5 9.1 6.5 41 4 41 305 5.3 0 5.6 5.2 07/12/2005 06:00:00 8.5 0.5 9.5 6.8 8.4 0.5 9.5 6.8 37 3 37 305 5.3 0 5.6 5.2 07/12/2005 06:10:00 8.3 0.5 9.5 6.8 8.2 0.6 9.1 6.5 39 4 38 305 5.3 0 5.6 5.2 07/12/2005 06:20:00 8.8 0.5 9.5 7.2 8.7 0.5 9.5 7.2 38 3 37 305 5.3 0 5.6 5.2 07/12/2005 06:30:00 8.3 0.6 9.5 6.8 8.1 0.6 9.5 6.5 40 3 41 305 5.3 0 5.6 5.2 07/12/2005 06:40:00 8.3 0.5 9.1 6.8 8.1 0.6 9.1 6.5 41 3 46 305 5.3 0 5.6 5.2 07/12/2005 06:50:00 8 0.6 9.1 6.5 7.9 0.6 9.1 6.1 38 4 39 305 5.3 0 5.6 5.2 07/12/2005 07:00:00 7.8 0.7 9.1 6.1 7.6 0.8 9.1 5.7 41 4 35 305 5.3 0 5.6 5.2 07/12/2005 07:10:00 8 0.6 9.1 6.5 7.8 0.6 9.1 6.1 43 5 40 305 5.3 0 5.6 5.2 07/12/2005 07:20:00 8 0.6 9.1 6.1 7.8 0.6 9.5 6.1 40 5 39 305 5.3 0 5.6 5.2 07/12/2005 07:30:00 7.6 0.5 8.8 6.1 7.4 0.6 8.8 5.3 45 5 44 305 5.3 0 5.6 5.2 07/12/2005 07:40:00 7.8 0.7 9.1 5.7 7.5 0.7 9.1 5.7 47 4 52 305 5.4 0 5.6 5.4 07/12/2005 07:50:00 7.7 0.5 8.8 6.5 7.5 0.5 8.8 6.1 49 3 52 305 5.4 0 5.6 5.2 07/12/2005 08:00:00 7.2 0.5 8.4 5.7 7 0.6 8.4 5.7 48 5 41 305 5.4 0 5.6 5.4 07/12/2005 08:10:00 7.6 0.6 8.8 6.1 7.4 0.8 8.8 5.3 48 3 48 305 5.4 0 5.6 5.4 07/12/2005 08:20:00 7.8 0.3 8.8 6.8 7.7 0.3 8.8 6.5 47 3 44 305 5.3 0 5.6 5.2 07/12/2005 08:30:00 6.9 0.7 8 5.3 6.8 0.7 8 4.9 45 4 44 305 5.4 0 5.6 5.2 07/12/2005 08:40:00 7.3 0.4 8 6.1 7.2 0.4 8 6.1 48 4 54 305 5.3 0 5.6 5.2 07/12/2005 08:50:00 7.2 0.3 8 6.5 7.1 0.4 8 5.7 51 3 50 305 5.3 0 5.6 5.2 07/12/2005 09:00:00 6.7 0.4 7.6 5.3 6.5 0.5 7.6 5.3 48 4 46 305 5.4 0 5.6 5.2 07/12/2005 09:10:00 6.5 0.6 7.6 5.3 6.3 0.7 7.6 4.9 52 5 51 305 5.4 0 5.6 5.2 07/12/2005 09:20:00 6.4 0.5 7.2 4.9 6.2 0.5 7.2 4.9 54 5 48 305 5.4 0 5.6 5.2 07/12/2005 09:30:00 6.2 0.4 7.2 4.6 5.9 0.5 6.8 4.2 51 5 51 305 5.4 0 5.9 5.4 07/12/2005 09:40:00 6.7 0.3 7.2 5.7 6.7 0.4 7.2 5.7 53 2 51 305 5.4 0 5.6 5.4 07/12/2005 09:50:00 6.6 0.4 7.6 5.3 6.4 0.5 7.2 4.6 52 4 50 305 5.5 0 5.9 5.4 07/12/2005 10:00:00 5.9 0.5 7.2 4.6 5.8 0.6 6.8 4.6 53 5 58 305 5.5 0 5.9 5.4 07/12/2005 10:10:00 6.2 0.4 6.8 4.9 6.1 0.4 6.8 4.6 55 4 55 305 5.5 0 5.9 5.4 07/12/2005 10:20:00 5.9 0.5 6.8 4.9 5.7 0.5 6.8 4.6 54 5 45 305 5.6 0.1 5.9 5.4 07/12/2005 10:30:00 5.5 0.5 6.5 4.2 5.4 0.5 6.5 3.8 55 4 50 305 5.5 0 5.9 5.4 07/12/2005 10:40:00 6.1 0.3 6.8 4.9 5.9 0.3 6.5 4.6 50 3 50 305 5.5 0 5.9 5.4 07/12/2005 10:50:00 5.5 0.4 6.5 4.6 5.4 0.4 6.1 4.2 52 3 53 305 5.7 0 5.9 5.6 07/12/2005 11:00:00 5.6 0.4 6.5 4.2 5.5 0.4 6.1 4.2 46 4 47 305 5.6 0 5.9 5.4 07/12/2005 11:10:00 5.4 0.3 6.1 4.6 5.3 0.4 6.1 4.2 47 4 41 305 5.8 0 6.1 5.6 07/12/2005 11:20:00 5.3 0.3 6.1 4.2 5.2 0.3 6.1 4.2 49 3 48 305 5.9 0 6.1 5.6 07/12/2005 11:30:00 5.4 0.3 6.1 4.6 5.2 0.4 6.1 3.8 51 3 55 305 6 0 6.1 5.9 07/12/2005 11:40:00 5.3 0.2 5.7 4.6 5.3 0.3 5.7 4.2 52 4 46 305 5.8 0 6.1 5.6 07/12/2005 11:50:00 5.1 0.3 6.1 4.2 5 0.3 5.7 4.2 53 5 50 305 5.8 0 5.9 5.6 07/12/2005 12:00:00 5 0.3 5.7 3.8 5 0.3 5.7 3.8 49 3 46 305 5.8 0 5.9 5.6 07/12/2005 12:10:00 4.8 0.3 5.7 3.8 4.7 0.3 5.3 3.8 52 6 51 305 6 0 6.1 5.6 07/12/2005 12:20:00 4.9 0.4 5.7 3.8 4.8 0.4 5.7 3.8 50 5 53 305 6 0 6.4 5.6 07/12/2005 12:30:00 5.3 0.3 5.7 4.6 5.3 0.3 6.1 4.6 40 3 39 305 5.9 0.1 6.1 5.6 07/12/2005 12:40:00 5.3 0.3 6.1 4.2 5.3 0.4 6.1 4.2 45 4 41 305 6 0 6.4 5.9 07/12/2005 12:50:00 5.4 0.3 6.1 4.6 5.3 0.4 6.1 4.2 46 4 44 305 6.1 0.1 6.4 5.9 07/12/2005 13:00:00 5.5 0.3 6.1 4.6 5.4 0.3 6.1 4.6 56 4 55 305 6.1 0.1 6.4 5.9 07/12/2005 13:10:00 5.5 0.3 6.1 4.9 5.5 0.3 6.1 4.6 56 3 58 305 6.2 0.1 6.4 5.9 07/12/2005 13:20:00 5.5 0.3 6.5 4.6 5.4 0.4 6.1 4.2 52 5 51 305 6.1 0.1 6.4 5.9 07/12/2005 13:30:00 5.4 0.3 6.1 4.6 5.3 0.4 6.1 4.2 49 6 49 305 6.3 0 6.4 5.9 07/12/2005 13:40:00 5.5 0.3 6.5 4.6 5.4 0.3 6.1 4.9 53 4 54 305 6.2 0 6.4 6.1 07/12/2005 13:50:00 5.6 0.3 6.5 4.9 5.6 0.3 6.1 4.6 49 4 51 305 6.3 0 6.4 5.9 07/12/2005 14:00:00 5.1 0.4 5.7 4.2 5.1 0.4 5.7 3.8 49 4 48 305 6.3 0 6.4 6.1 07/12/2005 14:10:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3 55 6 51 305 6.5 0 6.9 6.1 07/12/2005 14:20:00 3.9 0.3 4.9 3 3.9 0.3 4.9 3 50 4 48 305 6.3 0 6.4 6.1 07/12/2005 14:30:00 4.3 0.2 4.9 3.8 4.2 0.3 4.9 3.4 50 4 54 305 6.2 0 6.7 5.9 07/12/2005 14:40:00 4.4 0.3 5.3 3.8 4.4 0.3 5.3 3.4 50 5 49 305 6.4 0.1 6.7 6.1 07/12/2005 14:50:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 52 5 53 305 6.7 0.1 7.4 6.4 07/12/2005 15:00:00 4.4 0.3 5.3 3.8 4.3 0.3 5.7 3.4 46 4 50 305 6.8 0.2 7.4 6.4 07/12/2005 15:10:00 4.3 0.3 5.3 3.4 4.3 0.3 5.3 3.4 44 4 24 305 6.7 0.1 7.4 6.1 07/12/2005 15:20:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 2.6 41 5 45 305 6.8 0 7.4 6.7 07/12/2005 15:30:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 42 5 42 305 6.8 0 7.4 6.7 07/12/2005 15:40:00 4.8 0.2 5.3 4.2 4.8 0.3 5.3 4.2 44 4 47 305 6.8 0 7.4 6.7 07/12/2005 15:50:00 4.9 0.3 5.7 3.8 4.9 0.3 5.7 3.8 46 4 46 305 7 0.1 7.4 6.9 07/12/2005 16:00:00 4.7 0.3 5.3 4.2 4.7 0.3 5.3 3.8 40 5 43 305 6.8 0 7.2 6.7 07/12/2005 16:10:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 4.2 35 4 46 305 7 0 7.4 6.7 07/12/2005 16:20:00 4.7 0.4 5.3 2.6 4.7 0.4 5.3 3.4 35 4 39 305 7 0 7.4 6.9 07/12/2005 16:30:00 4.8 0.3 5.3 3.8 4.7 0.3 5.3 3.8 32 4 37 305 6.9 0 7.4 6.7 07/12/2005 16:40:00 4.6 0.4 5.3 3.4 4.5 0.4 5.3 3.4 34 3 33 305 7 0.1 7.7 6.9 07/12/2005 16:50:00 5 0.4 5.7 3.8 4.9 0.4 5.7 3.4 34 3 39 305 7 0 7.7 6.9 07/12/2005 17:00:00 5.1 0.2 5.7 4.2 5 0.3 5.7 4.2 34 3 38 305 7 0 7.4 6.9 07/12/2005 17:10:00 4.8 0.2 5.3 4.2 4.9 0.3 5.3 3.8 37 3 35 305 7 0 7.7 6.9 07/12/2005 17:20:00 4.9 0.2 5.3 4.2 4.7 0.3 5.3 3.8 35 5 39 305 7.1 0 7.7 7.2 07/12/2005 17:30:00 4.9 0.6 6.1 3.4 5.1 0.5 6.1 3.8 44 4 48 305 7.2 0 7.7 7.2 07/12/2005 17:40:00 3.6 0.4 4.6 2.6 4.3 0.4 5.3 3 43 7 44 305 7.2 0 7.7 7.2 07/12/2005 17:50:00 3.9 0.5 5.3 2.3 4.4 0.4 5.3 3 42 6 37 305 7.3 0 7.9 7.2 07/12/2005 18:00:00 4.4 0.6 6.5 2.6 4.4 0.7 5.7 2.6 65 17 69 305 7.9 0.4 9.2 7.4 07/12/2005 18:10:00 3.8 0.4 4.9 2.6 4.1 0.4 4.9 3 45 10 41 305 7.9 0.4 9.2 7.4 07/12/2005 18:20:00 4.5 0.4 5.3 3 4.9 0.4 5.3 3.8 46 3 44 305 7.2 0.1 7.9 7.2 07/12/2005 18:30:00 4.6 0.3 5.7 3.8 5.1 0.2 5.7 4.6 48 3 46 305 7.2 0.1 7.7 7.2 07/12/2005 18:40:00 4.7 0.2 5.3 4.2 5 0.2 5.7 3.8 45 2 44 305 7.1 0.1 7.7 7.2 07/12/2005 18:50:00 3.9 0.5 4.6 2.6 4.5 0.5 5.3 3 45 5 46 305 7 0 7.4 6.9 07/12/2005 19:00:00 3.6 0.5 4.9 2.3 4.2 0.4 4.9 3 42 5 45 305 7 0 7.2 6.9 07/12/2005 19:10:00 3.8 0.5 4.9 2.3 4.2 0.4 4.9 3 41 5 45 305 7 0 7.2 6.9 07/12/2005 19:20:00 4.1 0.6 5.3 2.3 4.6 0.4 5.3 3.4 44 5 44 305 7 0 7.4 6.9 07/12/2005 19:30:00 3.7 0.5 4.9 1.9 4.4 0.4 5.3 2.6 41 6 38 305 7 0 7.2 6.9 07/12/2005 19:40:00 4.2 0.6 6.1 2.6 4.7 0.5 6.1 3.4 41 7 58 305 7.2 0 7.4 7.2 07/12/2005 19:50:00 3.8 0.7 5.7 2.3 3.8 0.8 6.1 2.3 82 21 49 305 8 0.6 9.2 7.2 07/12/2005 20:00:00 3.5 0.5 4.6 1.9 3.4 0.5 4.6 1.1 91 13 95 305 8.9 0 9.2 8.7 07/12/2005 20:10:00 3.6 0.6 4.9 1.5 3.5 0.5 4.6 1.9 95 9 102 305 9.2 0.1 9.7 8.9 07/12/2005 20:20:00 3.5 0.6 4.6 1.5 3.4 0.5 4.6 1.5 102 7 94 305 9.1 0 9.7 8.9 07/12/2005 20:30:00 3.4 0.6 4.6 1.9 3.5 0.6 4.6 1.9 111 7 110 305 9 0 9.7 8.9 07/12/2005 20:40:00 3.4 0.5 4.6 1.9 3.4 0.5 4.6 1.9 104 13 107 305 8.7 0.1 9.2 8.2 07/12/2005 20:50:00 3 0.7 4.9 1.1 3 0.6 4.6 1.5 94 32 103 305 7.9 0.2 8.2 7.4 07/12/2005 21:00:00 2.8 0.6 4.2 1.1 2.9 0.6 4.6 1.5 117 6 125 305 8.5 0 8.9 8.2 07/12/2005 21:10:00 2.1 0.5 3.4 0.4 2.3 0.4 3.8 0.7 91 30 112 305 8.4 0.3 8.9 7.9 07/12/2005 21:20:00 2.6 0.7 3.8 0.7 2.6 0.7 4.2 0.7 62 26 50 305 8.2 0 8.4 7.9 07/12/2005 21:30:00 3.2 0.7 4.6 1.1 3.2 0.8 4.6 1.1 98 19 108 305 8.3 0 8.4 8.2 07/12/2005 21:40:00 3.3 0.4 4.6 2.3 3.4 0.4 4.6 2.3 118 7 112 305 8.4 0 8.4 8.2 07/12/2005 21:50:00 3.5 0.6 4.9 2.3 3.6 0.6 4.9 2.3 125 6 130 305 8.4 0 8.4 8.2 07/12/2005 22:00:00 2.4 0.7 3.8 0.7 2.6 0.6 4.2 1.1 130 6 125 305 8.6 0 8.7 8.4 07/12/2005 22:10:00 2.2 0.5 3.4 0.4 2.6 0.4 3.8 1.9 143 10 145 305 8.6 0 8.9 8.4 07/12/2005 22:20:00 1.5 0.6 3 0.4 1.7 0.5 3 0.4 187 51 133 305 8.6 0 8.7 8.4 07/12/2005 22:30:00 1.8 0.6 3.4 0.4 2 0.6 3.4 0.4 278 36 302 305 8.1 0 8.4 7.9 07/12/2005 22:40:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.5 230 13 211 305 8.2 0 8.4 8.2 07/12/2005 22:50:00 2.2 0.5 3.4 1.1 2.2 0.5 3.4 0.7 241 7 242 305 8 0 8.2 7.7 07/12/2005 23:00:00 1.3 0.5 2.3 0.4 1.3 0.6 2.3 0.4 247 10 245 305 7.7 0 7.9 7.7 07/12/2005 23:10:00 1.7 0.3 2.3 1.1 1.7 0.3 2.6 0.7 217 16 252 305 7.7 0 7.7 7.7 07/12/2005 23:20:00 1.9 0.4 3 0.7 1.9 0.4 3 0.7 201 9 196 305 7.6 0 7.9 7.7 07/12/2005 23:30:00 2.6 0.4 3.4 1.5 2.5 0.4 3.4 1.5 202 9 215 305 7.7 0 7.9 7.7 07/12/2005 23:40:00 2.1 0.4 3.4 1.1 2.1 0.5 3.4 0.7 194 8 192 305 7.8 0 7.9 7.7 07/12/2005 23:50:00 1.3 0.6 2.3 0.4 1.2 0.6 2.3 0.4 202 6 205 305 7.9 0 7.9 7.7 07/13/2005 00:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 182 2 192 305 7.9 0 7.9 7.7 07/13/2005 00:10:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 189 9 181 305 7.8 0 7.9 7.7 07/13/2005 00:20:00 1.2 0.6 2.3 0.4 1 0.6 1.9 0.4 212 11 209 305 7.9 0 7.9 7.7 07/13/2005 00:30:00 2.2 0.3 3 1.1 2.1 0.3 2.6 1.1 227 7 234 305 8.1 0 8.2 7.9 07/13/2005 00:40:00 2 0.3 2.6 1.1 1.9 0.3 2.6 1.1 207 9 196 305 8.1 0 8.2 7.9 07/13/2005 00:50:00 2.1 0.6 3.8 0.7 2.4 0.5 3.8 1.5 184 7 181 305 8.2 0 8.2 8.2 07/13/2005 01:00:00 3.4 0.5 4.6 1.9 3.5 0.6 4.9 2.3 187 5 186 305 8.2 0 8.4 8.2 07/13/2005 01:10:00 3.9 0.5 4.9 1.9 4.1 0.6 4.9 2.3 186 5 191 305 8.2 0 8.2 8.2 07/13/2005 01:20:00 2.8 0.7 4.2 1.1 3.3 0.4 4.2 2.3 179 9 187 305 8.2 0 8.4 8.2 07/13/2005 01:30:00 2.9 0.8 4.6 1.5 3.4 0.6 4.9 1.9 180 8 189 305 8.2 0 8.4 8.2 07/13/2005 01:40:00 3.7 0.5 4.9 1.9 4 0.4 4.9 2.6 184 5 182 305 8.3 0 8.4 8.2 07/13/2005 01:50:00 3.6 0.6 4.9 1.9 4 0.4 4.9 2.6 184 6 183 305 8.3 0 8.4 8.2 07/13/2005 02:00:00 3.9 0.5 4.9 2.3 4 0.4 5.3 2.6 188 5 183 305 8.2 0 8.4 8.2 07/13/2005 02:10:00 4.1 0.5 5.3 2.6 4.1 0.4 5.3 2.6 188 6 186 305 8.1 0 8.2 7.9 07/13/2005 02:20:00 4.4 0.5 5.7 2.6 4.4 0.5 5.7 3 191 7 194 305 8.1 0 8.2 7.9 07/13/2005 02:30:00 3.2 0.7 5.3 1.5 3.6 0.5 4.9 1.9 183 9 195 305 8 0 8.2 7.9 07/13/2005 02:40:00 5.1 0.8 6.8 3 5 0.9 6.5 3 197 5 194 305 8 0 8.2 7.9 07/13/2005 02:50:00 5.3 0.5 6.5 3.8 5.3 0.5 6.5 3.8 198 6 200 305 8.1 0 8.2 7.9 07/13/2005 03:00:00 5.5 0.5 6.5 4.2 5.4 0.6 6.8 3.8 191 6 196 305 8.1 0 8.2 7.9 07/13/2005 03:10:00 5.6 0.5 6.8 3.8 5.7 0.5 6.8 3.8 188 5 186 305 8.1 0 8.2 7.9 07/13/2005 03:20:00 4.6 0.5 5.7 3.4 4.7 0.5 6.5 3.4 187 6 196 305 8.1 0 8.2 7.9 07/13/2005 03:30:00 4.5 0.6 6.1 2.6 4.4 0.6 5.7 3 196 8 195 305 8.1 0 8.2 7.9 07/13/2005 03:40:00 5.4 0.6 6.5 3.8 5.3 0.6 6.5 3.8 199 5 194 305 8.1 0 8.2 7.9 07/13/2005 03:50:00 5.7 0.4 6.8 4.6 5.6 0.5 6.8 4.2 197 5 200 305 8 0 8.2 7.9 07/13/2005 04:00:00 5.1 0.8 6.8 2.6 5 0.8 6.8 2.6 193 7 196 305 8.1 0 8.2 7.9 07/13/2005 04:10:00 6 0.4 6.8 4.6 5.9 0.5 6.8 4.6 199 5 200 305 8.1 0 8.2 7.9 07/13/2005 04:20:00 6 0.5 6.8 4.6 5.9 0.5 6.8 4.2 193 5 194 305 8.1 0 8.2 7.9 07/13/2005 04:30:00 6.2 0.5 7.2 4.6 6.1 0.6 7.2 4.2 198 5 197 305 8.1 0 8.2 7.9 07/13/2005 04:40:00 5.9 0.6 7.2 4.2 5.7 0.7 7.2 4.2 199 5 203 305 8 0 8.2 7.9 07/13/2005 04:50:00 5.6 0.6 6.8 3.4 5.6 0.6 6.8 3.4 191 5 192 305 8 0 8.2 7.9 07/13/2005 05:00:00 6.4 0.9 8.8 3.4 6.3 0.9 8.4 3.8 200 8 203 305 8.1 0 8.2 7.9 07/13/2005 05:10:00 6.8 0.7 9.1 4.6 6.6 0.6 8.8 4.2 199 6 205 305 8 0 8.2 7.9 07/13/2005 05:20:00 7.4 0.7 8.8 5.7 7.2 0.7 8.8 5.7 204 4 206 305 7.9 0 8.2 7.7 07/13/2005 05:30:00 6.4 0.6 8 4.6 6.3 0.6 7.6 4.6 204 5 208 305 7.8 0 7.9 7.7 07/13/2005 05:40:00 7 0.7 8.4 4.9 6.7 0.8 8 4.9 206 5 208 305 7.7 0 7.9 7.7 07/13/2005 05:50:00 6.6 0.5 7.6 4.9 6.4 0.6 7.6 4.6 196 6 202 305 7.7 0 7.9 7.7 07/13/2005 06:00:00 6.8 0.4 8 4.9 6.7 0.5 8 4.9 197 4 193 305 7.7 0 7.9 7.7 07/13/2005 06:10:00 6.9 0.5 8 5.7 6.7 0.6 8 5.3 197 4 194 305 7.7 0 7.9 7.7 07/13/2005 06:20:00 6.6 0.5 7.6 5.3 6.5 0.6 7.6 4.9 198 4 192 305 7.7 0 7.9 7.7 07/13/2005 06:30:00 6.4 0.4 7.6 4.6 6.3 0.5 7.2 4.2 200 5 200 305 7.6 0 7.7 7.7 07/13/2005 06:40:00 6.7 0.5 8 4.9 6.6 0.6 8 4.6 200 4 205 305 7.6 0 7.7 7.7 07/13/2005 06:50:00 6.9 0.5 8 5.7 6.8 0.5 8 4.9 201 4 205 305 7.6 0 7.7 7.7 07/13/2005 07:00:00 6.9 0.5 8 4.9 6.8 0.5 8 4.9 196 5 203 305 7.5 0 7.7 7.4 07/13/2005 07:10:00 6.5 0.5 7.6 4.9 6.3 0.5 7.6 4.6 197 5 198 305 7.6 0 7.7 7.4 07/13/2005 07:20:00 6.3 0.5 7.2 4.6 6.1 0.6 7.6 4.6 194 5 203 305 7.6 0 7.7 7.4 07/13/2005 07:30:00 6.8 0.5 8 5.7 6.7 0.5 8 5.3 197 4 198 305 7.5 0 7.7 7.4 07/13/2005 07:40:00 7.1 0.5 8.4 5.3 7 0.6 8.4 4.6 198 4 198 305 7.5 0 7.7 7.4 07/13/2005 07:50:00 7.3 0.6 8.8 5.3 7.3 0.7 8.8 4.6 197 4 202 305 7.6 0 7.7 7.7 07/13/2005 08:00:00 7.5 0.5 8.8 5.7 7.4 0.5 8.8 5.3 198 4 199 305 7.5 0 7.7 7.4 07/13/2005 08:10:00 7.8 0.5 8.8 6.1 7.6 0.6 8.8 5.7 199 4 201 305 7.6 0 7.7 7.7 07/13/2005 08:20:00 7.9 0.6 9.5 6.5 7.8 0.6 9.1 5.7 197 4 203 305 7.6 0 7.7 7.7 07/13/2005 08:30:00 8.1 0.6 9.5 6.1 7.9 0.7 9.5 6.1 199 5 199 305 7.6 0 7.7 7.4 07/13/2005 08:40:00 7.5 0.7 9.1 5.7 7.4 0.8 8.8 4.9 197 5 200 305 7.5 0 7.7 7.4 07/13/2005 08:50:00 7.3 0.6 8.8 5.3 7.2 0.7 8.4 5.3 196 5 200 305 7.6 0 7.7 7.7 07/13/2005 09:00:00 7.9 0.6 9.1 5.7 7.7 0.7 9.1 5.7 198 4 198 305 7.6 0 7.7 7.7 07/13/2005 09:10:00 7.4 0.5 8.8 6.1 7.4 0.6 8.8 5.7 198 4 198 305 7.6 0 7.7 7.7 07/13/2005 09:20:00 7.4 0.5 9.1 6.1 7.1 0.6 8.8 5.3 197 4 201 305 7.7 0 7.9 7.7 07/13/2005 09:30:00 7.8 0.8 9.9 5.7 7.5 0.8 9.5 4.9 205 6 213 305 7.7 0 7.9 7.7 07/13/2005 09:40:00 7.4 1 9.5 4.6 6.8 1 9.5 4.2 211 6 207 305 7.9 0 7.9 7.7 07/13/2005 09:50:00 8.2 0.8 9.9 5.7 7.7 1 10.3 4.6 210 6 214 305 7.8 0 7.9 7.7 07/13/2005 10:00:00 7.4 0.8 9.1 4.9 7.2 0.8 9.1 4.9 199 8 200 305 8 0 8.2 7.9 07/13/2005 10:10:00 7.6 0.6 8.8 5.7 7.4 0.6 8.8 5.3 199 5 194 305 8 0 8.2 7.9 07/13/2005 10:20:00 7.9 0.5 9.1 6.5 7.8 0.6 9.1 6.1 200 4 203 305 8.1 0 8.2 7.9 07/13/2005 10:30:00 8.2 0.6 9.5 6.1 7.9 0.8 9.5 4.9 196 5 196 305 8 0 8.2 7.9 07/13/2005 10:40:00 8.7 0.5 10.3 7.2 8.5 0.6 9.9 6.5 195 4 200 305 8 0 8.2 7.9 07/13/2005 10:50:00 8.9 0.6 10.3 6.8 8.6 0.7 9.9 6.1 203 4 202 305 7.9 0 8.2 7.9 07/13/2005 11:00:00 8.2 0.7 9.5 6.1 7.9 0.8 9.5 5.3 204 4 201 305 7.9 0 8.2 7.9 07/13/2005 11:10:00 7.6 0.5 8.8 6.1 7.3 0.6 8.4 5.7 203 4 203 305 8 0 8.2 7.9 07/13/2005 11:20:00 8 0.5 8.8 6.8 7.7 0.6 9.1 5.7 201 4 201 305 8 0 8.2 7.9 07/13/2005 11:30:00 8.3 0.5 9.5 6.8 8.1 0.6 9.5 6.1 199 3 200 305 7.9 0 8.2 7.7 07/13/2005 11:40:00 8.9 0.8 11.5 6.5 8.6 0.8 11.1 6.5 197 4 194 305 7.8 0 7.9 7.7 07/13/2005 11:50:00 9.5 1.1 11.5 7.2 8.9 1.2 11.5 5.7 212 7 201 305 7.7 0 7.9 7.7 07/13/2005 12:00:00 8.2 0.8 10.3 5.7 7.4 1 9.5 4.6 208 5 203 305 7.8 0 7.9 7.7 07/13/2005 12:10:00 9.5 0.7 11.1 6.8 9.1 0.9 10.7 6.5 203 5 208 305 7.8 0 7.9 7.7 07/13/2005 12:20:00 9.2 0.8 11.1 6.8 8.9 0.9 10.7 6.1 203 4 207 305 7.7 0 7.9 7.7 07/13/2005 12:30:00 8.6 0.6 9.9 6.5 8.5 0.7 9.9 6.5 200 4 201 305 7.7 0 7.9 7.7 07/13/2005 12:40:00 8.9 0.6 9.9 7.2 8.6 0.8 10.3 6.1 199 4 200 305 7.7 0 7.9 7.7 07/13/2005 12:50:00 9.4 0.6 10.7 7.2 9.2 0.7 10.7 7.2 201 4 198 305 7.8 0 7.9 7.7 07/13/2005 13:00:00 9.7 0.7 11.8 7.6 9.5 0.7 11.8 7.2 202 4 208 305 8 0 8.2 7.7 07/13/2005 13:10:00 9 0.6 10.7 7.2 8.7 0.7 10.3 6.5 202 4 200 305 8.1 0 8.2 7.9 07/13/2005 13:20:00 8.7 0.6 10.3 6.5 8.6 0.7 10.3 5.3 202 4 203 305 8.1 0 8.2 7.9 07/13/2005 13:30:00 9.2 0.7 11.1 6.5 9 0.7 10.7 6.8 199 6 199 305 8.1 0 8.2 7.9 07/13/2005 13:40:00 9.7 0.8 11.1 7.2 9.6 0.9 11.8 7.2 200 5 193 305 8.1 0 8.2 7.9 07/13/2005 13:50:00 9.7 0.6 11.1 8 9.5 0.7 11.1 7.2 202 4 208 305 8 0 8.2 7.9 07/13/2005 14:00:00 10.5 0.8 12.6 8 10.2 1 12.2 6.5 202 4 203 305 8.1 0 8.2 7.9 07/13/2005 14:10:00 10.4 0.8 12.6 8.4 10.1 0.8 12.2 7.6 204 5 210 305 8 0 8.2 7.9 07/13/2005 14:20:00 10.1 1 13 7.2 9.6 1.1 13 6.1 208 5 208 305 8 0 8.2 7.9 07/13/2005 14:30:00 9.4 0.8 11.5 6.8 8.9 1 11.5 6.1 207 5 209 305 8 0 8.2 7.9 07/13/2005 14:40:00 10.3 0.7 12.6 8.4 9.9 0.8 12.2 7.2 206 4 205 305 8 0 8.2 7.9 07/13/2005 14:50:00 10.4 0.9 12.6 8 9.9 1 12.2 6.8 208 5 210 305 7.9 0 8.2 7.7 07/13/2005 15:00:00 9.6 0.8 11.5 7.2 8.9 0.9 11.1 6.5 209 5 212 305 7.9 0 7.9 7.7 07/13/2005 15:10:00 9.4 0.6 10.7 6.8 9 0.7 10.3 6.1 206 4 203 305 7.7 0 7.9 7.7 07/13/2005 15:20:00 8.9 0.7 10.7 7.2 8.6 0.8 10.3 6.5 205 4 211 305 7.7 0 7.9 7.7 07/13/2005 15:30:00 9.5 0.5 10.7 8 9.2 0.7 10.3 6.8 205 4 198 305 7.7 0 7.9 7.7 07/13/2005 15:40:00 9.3 0.7 10.7 6.8 9 0.7 10.7 6.8 205 4 205 305 7.9 0 7.9 7.7 07/13/2005 15:50:00 9.1 0.7 10.7 7.2 8.8 0.8 10.7 5.7 206 5 210 305 7.8 0 7.9 7.7 07/13/2005 16:00:00 9.4 0.6 10.7 7.6 9.1 0.7 10.7 6.5 203 4 208 305 7.7 0 7.9 7.7 07/13/2005 16:10:00 9.5 0.5 11.5 8 9.3 0.6 10.7 7.2 199 4 194 305 7.8 0 7.9 7.7 07/13/2005 16:20:00 9.2 0.8 11.1 6.1 8.9 0.8 11.1 6.1 196 4 203 305 7.9 0 7.9 7.7 07/13/2005 16:30:00 9.8 0.6 11.1 7.6 9.6 0.6 10.7 7.6 199 5 201 305 7.8 0 7.9 7.7 07/13/2005 16:40:00 9.9 0.7 11.5 8 9.7 0.8 11.5 7.2 201 4 206 305 7.8 0 7.9 7.7 07/13/2005 16:50:00 9.9 0.7 11.5 7.6 9.6 0.8 11.5 6.8 204 5 203 305 7.7 0 7.9 7.7 07/13/2005 17:00:00 9 0.6 10.3 6.8 8.6 0.8 10.3 6.1 205 5 213 305 7.7 0 7.9 7.7 07/13/2005 17:10:00 9.3 0.6 10.3 7.6 9 0.7 10.7 6.8 198 4 208 305 7.7 0 7.9 7.7 07/13/2005 17:20:00 9.6 0.8 11.5 7.2 9.4 0.9 11.5 6.5 200 3 199 305 7.9 0 7.9 7.7 07/13/2005 17:30:00 9.5 0.7 11.5 7.6 9.2 0.7 11.1 6.8 199 4 210 305 7.9 0 8.2 7.9 07/13/2005 17:40:00 10 0.8 12.2 7.6 9.9 0.8 11.8 7.2 202 4 202 305 7.9 0 7.9 7.7 07/13/2005 17:50:00 9.6 0.7 11.8 7.2 9.2 0.8 11.5 7.2 203 4 208 305 8 0 8.2 7.9 07/13/2005 18:00:00 9.2 0.6 10.7 7.6 9 0.7 10.3 6.5 203 4 205 305 7.9 0 8.2 7.9 07/13/2005 18:10:00 10.1 0.6 11.8 8.4 9.9 0.7 11.5 7.2 203 4 200 305 7.9 0 7.9 7.7 07/13/2005 18:20:00 9.5 0.6 10.7 7.2 9.2 0.7 10.7 6.5 203 4 202 305 7.9 0 7.9 7.7 07/13/2005 18:30:00 10 0.7 12.2 7.6 9.8 0.8 11.8 6.5 202 5 203 305 7.8 0 7.9 7.7 07/13/2005 18:40:00 9.2 0.6 11.1 7.2 9 0.7 10.7 6.8 200 4 210 305 7.7 0 7.9 7.7 07/13/2005 18:50:00 9.2 0.7 11.1 7.2 8.9 0.8 10.7 6.5 201 4 198 305 7.7 0 7.9 7.7 07/13/2005 19:00:00 9.3 0.6 11.1 8 9.1 0.7 10.3 6.8 204 4 202 305 7.7 0 7.9 7.7 07/13/2005 19:10:00 9.6 0.7 11.5 8 9.4 0.7 11.5 7.2 202 4 204 305 7.7 0 7.9 7.7 07/13/2005 19:20:00 10 0.6 11.5 8 9.7 0.8 11.1 6.8 201 4 196 305 7.9 0 7.9 7.7 07/13/2005 19:30:00 9.4 0.6 11.1 7.6 9.2 0.7 10.7 7.2 202 4 202 305 7.9 0 7.9 7.7 07/13/2005 19:40:00 9.8 0.6 11.5 7.2 9.5 0.8 11.5 7.2 201 4 205 305 7.9 0 7.9 7.9 07/13/2005 19:50:00 9.8 0.6 11.5 7.6 9.5 0.6 10.7 7.6 203 4 207 305 7.8 0 7.9 7.7 07/13/2005 20:00:00 9.4 0.6 10.7 7.2 9.1 0.7 10.7 6.8 203 5 197 305 7.7 0 7.9 7.7 07/13/2005 20:10:00 10.3 0.7 12.2 7.6 9.9 0.7 11.5 7.2 205 4 213 305 7.7 0 7.9 7.7 07/13/2005 20:20:00 9.4 0.8 11.1 7.2 9 0.9 11.5 6.1 206 4 213 305 7.7 0 7.9 7.7 07/13/2005 20:30:00 9.1 0.7 10.7 6.5 8.7 0.9 10.7 6.1 206 5 210 305 7.7 0 7.9 7.7 07/13/2005 20:40:00 9.1 0.7 10.7 6.8 8.7 0.8 10.7 6.1 205 5 208 305 7.7 0 7.9 7.7 07/13/2005 20:50:00 9.6 0.6 11.1 8 9.3 0.6 10.7 7.6 205 4 208 305 7.7 0 7.9 7.7 07/13/2005 21:00:00 9.7 0.6 11.1 7.2 9.3 0.7 10.7 7.6 205 4 210 305 7.7 0 7.9 7.7 07/13/2005 21:10:00 9.5 0.6 10.7 8 9.1 0.7 10.7 7.2 202 5 201 305 7.7 0 7.7 7.7 07/13/2005 21:20:00 9.8 0.6 11.1 8.4 9.5 0.6 11.1 7.6 203 4 203 305 7.7 0 7.9 7.7 07/13/2005 21:30:00 10.3 0.7 11.8 8 10 0.7 11.8 7.6 205 4 208 305 7.7 0 7.9 7.7 07/13/2005 21:40:00 9.9 0.6 11.5 8 9.6 0.7 11.5 7.6 204 4 204 305 7.7 0 7.9 7.7 07/13/2005 21:50:00 9.7 0.8 11.5 6.8 9.4 0.8 11.1 7.2 205 4 204 305 7.6 0 7.7 7.7 07/13/2005 22:00:00 9.7 0.6 11.5 8 9.2 0.7 11.5 7.2 206 4 210 305 7.6 0 7.7 7.7 07/13/2005 22:10:00 9.6 0.6 11.1 7.6 9.4 0.7 11.1 7.2 203 4 205 305 7.6 0 7.7 7.7 07/13/2005 22:20:00 9.7 0.6 11.1 7.6 9.5 0.6 11.1 7.2 204 4 206 305 7.6 0 7.7 7.7 07/13/2005 22:30:00 9.8 0.6 11.1 8 9.4 0.6 10.7 7.6 203 4 206 305 7.6 0 7.7 7.7 07/13/2005 22:40:00 9.8 0.7 11.5 6.8 9.3 0.8 11.5 6.5 205 5 206 305 7.6 0 7.7 7.7 07/13/2005 22:50:00 9.6 0.6 10.7 7.2 9.2 0.7 10.3 6.8 205 4 208 305 7.6 0 7.7 7.7 07/13/2005 23:00:00 9.7 0.5 11.1 8.4 9.4 0.6 10.7 7.6 201 3 198 305 7.6 0 7.7 7.4 07/13/2005 23:10:00 9.7 0.6 11.1 8 9.4 0.6 10.7 7.6 201 4 206 305 7.6 0 7.7 7.7 07/13/2005 23:20:00 10 0.5 11.5 8.8 9.8 0.6 11.5 7.6 199 4 200 305 7.6 0 7.7 7.7 07/13/2005 23:30:00 10.2 0.6 11.5 7.6 9.8 0.8 11.1 7.2 197 4 196 305 7.6 0 7.7 7.7 07/13/2005 23:40:00 10.8 0.7 12.6 8.4 10.5 0.8 12.6 7.6 197 3 198 305 7.6 0 7.7 7.7 07/13/2005 23:50:00 10.5 0.7 12.2 8.8 10.2 0.8 11.8 7.2 197 4 193 305 7.7 0 7.9 7.7 07/14/2005 00:00:00 10.5 0.5 11.5 9.1 10.2 0.6 11.8 8 199 3 199 305 7.6 0 7.9 7.7 07/14/2005 00:10:00 10.1 0.7 11.5 8.4 10 0.7 11.5 7.6 199 4 205 305 7.6 0 7.7 7.7 07/14/2005 00:20:00 9.9 0.6 11.5 8 9.6 0.7 11.1 7.6 201 4 205 305 7.6 0 7.7 7.7 07/14/2005 00:30:00 9.7 0.7 11.5 7.6 9.4 0.8 11.1 6.1 201 3 199 305 7.6 0 7.7 7.4 07/14/2005 00:40:00 9.9 0.6 11.5 8 9.6 0.6 11.5 7.6 201 3 204 305 7.6 0 7.7 7.4 07/14/2005 00:50:00 9.7 0.6 11.1 8 9.5 0.6 10.7 7.2 201 3 200 305 7.6 0 7.7 7.4 07/14/2005 01:00:00 9.7 0.6 11.5 8 9.4 0.6 11.1 7.6 201 3 194 305 7.6 0 7.7 7.7 07/14/2005 01:10:00 9.6 0.5 11.1 8 9.3 0.5 10.7 8 202 3 200 305 7.6 0 7.7 7.7 07/14/2005 01:20:00 9.7 0.5 11.1 8.4 9.3 0.6 11.5 7.6 203 3 198 305 7.6 0 7.7 7.7 07/14/2005 01:30:00 9.5 0.5 10.7 7.6 9.2 0.7 11.1 6.5 202 3 208 305 7.7 0 7.7 7.7 07/14/2005 01:40:00 9.5 0.7 11.5 7.2 9.3 0.7 11.1 6.8 202 3 200 305 7.6 0 7.7 7.7 07/14/2005 01:50:00 9.4 0.6 11.1 7.2 9.1 0.7 10.7 7.2 202 4 208 305 7.7 0 7.9 7.7 07/14/2005 02:00:00 9.7 0.6 11.5 7.6 9.5 0.6 11.1 7.6 202 4 203 305 7.7 0 7.9 7.7 07/14/2005 02:10:00 9.7 0.6 11.1 8.4 9.3 0.6 11.1 7.6 204 4 202 305 7.7 0 7.9 7.7 07/14/2005 02:20:00 9.4 0.6 11.1 7.2 9.1 0.7 11.1 6.5 201 4 201 305 7.7 0 7.7 7.7 07/14/2005 02:30:00 9.8 0.5 11.1 8 9.5 0.6 11.5 6.8 201 3 202 305 7.7 0 7.7 7.7 07/14/2005 02:40:00 9.7 0.6 11.1 7.6 9.4 0.7 11.1 7.2 202 4 198 305 7.6 0 7.9 7.7 07/14/2005 02:50:00 9.9 0.5 11.1 8.8 9.6 0.6 11.1 8 203 3 199 305 7.6 0 7.7 7.7 07/14/2005 03:00:00 9.6 0.5 11.1 7.6 9.3 0.6 10.7 6.8 203 3 203 305 7.6 0 7.7 7.7 07/14/2005 03:10:00 9.4 0.6 10.7 7.6 9 0.7 10.7 6.8 203 4 210 305 7.6 0 7.7 7.7 07/14/2005 03:20:00 9.6 0.6 11.1 8 9.2 0.7 11.1 7.2 203 3 199 305 7.6 0 7.7 7.7 07/14/2005 03:30:00 9.1 0.5 10.3 7.6 8.8 0.6 9.9 6.5 203 3 208 305 7.6 0 7.7 7.7 07/14/2005 03:40:00 9.1 0.6 10.3 6.8 8.6 0.6 10.3 6.5 205 4 208 305 7.6 0 7.7 7.7 07/14/2005 03:50:00 9.1 0.6 10.7 6.8 8.6 0.7 10.3 6.5 206 4 205 305 7.6 0 7.7 7.7 07/14/2005 04:00:00 9.1 0.6 10.7 6.5 8.6 0.7 10.7 6.8 207 4 207 305 7.7 0 7.7 7.7 07/14/2005 04:10:00 8.6 0.6 10.7 7.2 8.3 0.6 10.7 6.5 205 4 203 305 7.7 0 7.7 7.7 07/14/2005 04:20:00 8.7 0.5 9.9 7.6 8.5 0.5 9.5 6.8 202 3 199 305 7.7 0 7.7 7.7 07/14/2005 04:30:00 8.4 0.5 9.5 6.5 8.2 0.5 9.1 6.5 203 3 207 305 7.7 0 7.7 7.7 07/14/2005 04:40:00 8.4 0.5 9.9 7.2 8.2 0.6 9.5 6.1 200 3 198 305 7.7 0 7.7 7.7 07/14/2005 04:50:00 8.5 0.5 10.3 6.8 8.3 0.5 9.5 6.1 199 3 194 305 7.7 0 7.9 7.7 07/14/2005 05:00:00 8.6 0.5 9.9 7.2 8.4 0.6 9.9 6.8 199 3 204 305 7.7 0 7.9 7.7 07/14/2005 05:10:00 8.7 0.5 10.3 6.8 8.5 0.5 9.9 6.8 199 4 196 305 7.7 0 7.9 7.7 07/14/2005 05:20:00 8.3 0.5 9.5 6.1 8.2 0.6 9.5 6.1 199 4 196 305 7.7 0 7.9 7.7 07/14/2005 05:30:00 8.1 0.6 9.5 6.5 7.8 0.7 9.1 5.3 198 4 197 305 7.7 0 7.9 7.7 07/14/2005 05:40:00 8 0.6 9.5 5.3 7.8 0.7 9.1 5.3 196 4 194 305 7.7 0 7.9 7.7 07/14/2005 05:50:00 7.8 0.6 9.1 5.7 7.6 0.7 9.1 5.7 193 5 194 305 7.7 0 7.9 7.7 07/14/2005 06:00:00 7.8 0.6 9.1 5.3 7.6 0.8 9.1 5.3 190 5 184 305 7.8 0 7.9 7.7 07/14/2005 06:10:00 8.3 0.6 9.9 5.7 8.2 0.7 9.5 5.3 193 4 190 305 7.8 0 7.9 7.7 07/14/2005 06:20:00 8.6 0.7 9.9 6.1 8.4 0.8 9.9 5.7 194 4 193 305 7.8 0 7.9 7.7 07/14/2005 06:30:00 9.1 0.7 10.3 6.5 8.9 0.8 10.3 6.5 194 4 197 305 7.8 0 7.9 7.7 07/14/2005 06:40:00 9.1 0.6 10.3 6.8 8.9 0.8 10.3 6.8 194 4 195 305 7.8 0 7.9 7.7 07/14/2005 06:50:00 8.9 0.6 10.3 7.2 8.6 0.8 10.3 6.1 194 4 202 305 7.8 0 7.9 7.7 07/14/2005 07:00:00 8.7 0.5 9.9 6.8 8.4 0.8 10.3 6.1 195 5 196 305 7.9 0 7.9 7.7 07/14/2005 07:10:00 9 0.6 10.3 6.8 8.8 0.7 10.7 6.8 194 4 195 305 7.9 0 7.9 7.7 07/14/2005 07:20:00 9.3 0.8 11.1 6.5 9.1 0.9 11.1 6.5 194 5 194 305 7.9 0 8.2 7.7 07/14/2005 07:30:00 9.2 0.8 11.1 6.8 8.9 0.9 10.7 6.1 192 4 191 305 8 0 8.2 7.9 07/14/2005 07:40:00 9.3 0.9 11.5 6.8 9.1 1 11.1 5.7 192 4 192 305 8 0 8.2 7.9 07/14/2005 07:50:00 9.3 0.6 10.7 7.2 9 0.7 10.7 6.8 193 5 194 305 8.1 0 8.2 7.9 07/14/2005 08:00:00 9.6 0.7 11.1 7.6 9.2 0.9 11.1 6.8 193 5 193 305 8.1 0 8.2 7.9 07/14/2005 08:10:00 9.3 0.7 11.1 7.2 9 0.8 11.1 6.8 193 4 194 305 8.2 0 8.2 8.2 07/14/2005 08:20:00 9.3 0.7 11.1 7.2 9 0.9 10.7 6.1 194 5 198 305 8.2 0 8.2 8.2 07/14/2005 08:30:00 9.5 0.6 11.5 8 9.3 0.8 11.1 6.5 195 4 195 305 8.1 0 8.2 7.9 07/14/2005 08:40:00 9 0.7 10.7 6.8 8.7 0.8 10.3 6.8 195 5 203 305 8.1 0 8.2 7.9 07/14/2005 08:50:00 9.6 0.8 11.5 7.6 9.2 0.9 11.5 6.8 194 5 196 305 8.1 0 8.2 8.2 07/14/2005 09:00:00 9.7 0.7 11.8 7.2 9.4 0.8 11.1 6.5 196 4 197 305 8.1 0 8.2 7.9 07/14/2005 09:10:00 9.8 0.8 11.5 7.2 9.5 0.9 11.5 6.8 197 4 190 305 8.1 0 8.2 7.9 07/14/2005 09:20:00 10.4 0.6 11.8 8.8 10.2 0.7 11.8 8 198 3 198 305 8 0 8.2 7.9 07/14/2005 09:30:00 10 0.6 11.8 8 9.7 0.8 11.5 7.6 197 4 201 305 8 0 8.2 7.9 07/14/2005 09:40:00 10.8 0.7 12.6 9.1 10.5 0.8 12.6 8 195 4 196 305 8 0 8.2 7.9 07/14/2005 09:50:00 10.3 0.8 12.2 8 9.9 0.9 11.8 7.6 196 4 200 305 8 0 8.2 7.9 07/14/2005 10:00:00 10.1 0.8 12.2 7.6 9.8 0.9 11.8 6.8 195 4 192 305 8 0 8.2 7.9 07/14/2005 10:10:00 10.4 0.7 12.2 8.4 10 1 12.2 7.2 196 4 200 305 8 0 8.2 7.9 07/14/2005 10:20:00 10.2 0.8 12.2 8 9.9 1 12.2 6.8 195 4 194 305 8 0 8.2 7.9 07/14/2005 10:30:00 10.3 0.8 12.2 7.6 9.9 1 11.8 6.5 194 4 189 305 8 0 8.2 7.9 07/14/2005 10:40:00 10.6 0.7 12.2 8.4 10.2 1 12.2 6.8 195 4 200 305 8 0 8.2 7.9 07/14/2005 10:50:00 10.6 0.8 12.6 8.4 10.2 1 12.6 7.2 196 4 198 305 8 0 8.2 7.9 07/14/2005 11:00:00 10.7 0.8 12.6 8 10.3 1 12.6 7.6 196 4 194 305 8 0 8.2 7.9 07/14/2005 11:10:00 10.4 0.8 12.2 8.4 10 1 12.2 6.5 195 5 192 305 8 0 8.2 7.9 07/14/2005 11:20:00 10.4 0.7 12.6 8.4 10 1 11.8 6.8 194 4 203 305 8 0 8.2 7.9 07/14/2005 11:30:00 9.8 0.9 11.8 7.6 9.5 1.1 11.8 6.8 194 5 191 305 8 0 8.2 7.9 07/14/2005 11:40:00 10.3 0.9 12.6 7.2 9.9 1 12.2 6.5 194 4 193 305 8 0 8.2 7.9 07/14/2005 11:50:00 10.3 0.9 12.2 8 9.8 1.1 12.2 7.2 194 5 189 305 8 0 8.2 7.9 07/14/2005 12:00:00 10.7 0.7 12.2 8 10.4 1 12.2 6.5 196 5 205 305 8 0 8.2 7.9 07/14/2005 12:10:00 10.9 0.7 12.6 8.8 10.5 0.9 12.6 7.6 196 3 194 305 8 0 8.2 7.9 07/14/2005 12:20:00 11.2 0.8 13 8 10.8 1 12.6 7.2 198 4 193 305 8.1 0 8.2 7.9 07/14/2005 12:30:00 11.1 0.8 13 8.4 10.6 1 12.6 7.6 198 5 198 305 8.2 0 8.2 8.2 07/14/2005 12:40:00 11 0.9 12.6 8.4 10.7 1.1 13 7.6 197 4 194 305 8.1 0 8.2 7.9 07/14/2005 12:50:00 11.3 0.8 13 8.4 10.9 1 13 8 198 4 198 305 8.2 0 8.2 7.9 07/14/2005 13:00:00 11.2 0.6 12.6 9.9 10.9 0.7 12.2 8.4 197 4 201 305 8.2 0 8.2 8.2 07/14/2005 13:10:00 11.1 0.7 13 9.1 10.8 0.7 12.2 8.8 197 4 181 305 8.2 0 8.4 8.2 07/14/2005 13:20:00 10.9 0.8 13 8.8 10.5 1 12.6 8 196 5 208 305 8.2 0 8.2 8.2 07/14/2005 13:30:00 11.4 0.9 13.3 8 11 1.1 13 7.2 197 4 193 305 8.1 0 8.2 7.9 07/14/2005 13:40:00 11.2 0.9 13 8.4 10.8 1 12.6 7.6 196 4 197 305 8.1 0 8.2 8.2 07/14/2005 13:50:00 11.1 0.7 13.3 9.1 10.8 0.9 13.3 7.6 197 4 197 305 8.2 0 8.2 8.2 07/14/2005 14:00:00 10.7 0.7 12.2 7.6 10.4 0.8 11.8 7.6 196 4 196 305 8.2 0 8.2 8.2 07/14/2005 14:10:00 10.7 0.7 12.2 8.4 10.3 0.8 12.2 7.6 196 5 197 305 8.2 0 8.4 8.2 07/14/2005 14:20:00 10.5 1 12.6 7.2 10.1 1.1 12.6 6.1 196 5 191 305 8.3 0 8.4 8.2 07/14/2005 14:30:00 10.6 0.9 12.6 7.6 10.2 1 12.2 6.5 196 5 194 305 8.3 0 8.4 8.2 07/14/2005 14:40:00 10.9 1 13.3 7.2 10.5 1.1 13 6.8 196 5 199 305 8.4 0 8.4 8.2 07/14/2005 14:50:00 11.5 0.7 13.3 9.5 11.3 0.7 13 8.4 200 4 198 305 8.4 0 8.7 8.2 07/14/2005 15:00:00 11.2 0.7 13 9.5 10.9 0.8 13 8.4 199 4 198 305 8.6 0 8.9 8.4 07/14/2005 15:10:00 11.7 0.7 13.3 9.1 11.4 0.9 13.3 8.8 200 3 207 305 8.7 0 8.9 8.7 07/14/2005 15:20:00 11.7 0.7 13.3 9.5 11.3 0.8 13 9.1 199 4 207 305 8.8 0 8.9 8.7 07/14/2005 15:30:00 11.7 0.7 13.3 9.9 11.3 0.7 13 9.1 202 4 196 305 8.8 0 8.9 8.7 07/14/2005 15:40:00 11.3 0.9 13 8.8 11 1.1 13 8 201 4 208 305 8.8 0 8.9 8.7 07/14/2005 15:50:00 10.9 0.7 13 8.8 10.7 0.8 13 8 200 4 201 305 8.7 0 8.9 8.4 07/14/2005 16:00:00 11.3 0.7 13 9.1 10.9 0.8 12.6 8.4 200 4 206 305 8.8 0 8.9 8.7 07/14/2005 16:10:00 11.2 0.8 13.3 9.1 10.8 1 13 7.2 199 4 193 305 8.8 0 8.9 8.7 07/14/2005 16:20:00 10.8 0.7 12.6 8.4 10.5 0.8 12.2 7.6 200 4 199 305 8.8 0 9.2 8.7 07/14/2005 16:30:00 10.6 0.8 12.2 8 10.1 0.9 12.2 7.2 200 5 203 305 8.9 0 9.2 8.9 07/14/2005 16:40:00 10.4 1 12.2 7.2 10.1 1.1 12.2 6.8 199 5 202 305 8.9 0 8.9 8.7 07/14/2005 16:50:00 10.6 0.9 13 7.6 10.1 1 12.6 7.2 198 5 208 305 8.9 0 9.2 8.9 07/14/2005 17:00:00 10.8 0.9 13 8 10.4 1.1 13 7.6 199 5 199 305 8.9 0 9.2 8.9 07/14/2005 17:10:00 10.9 0.7 12.6 8.8 10.5 0.9 12.6 7.2 200 4 197 305 8.9 0 9.2 8.9 07/14/2005 17:20:00 11 0.7 13.3 9.1 10.6 0.8 13 7.6 201 4 202 305 8.9 0 9.2 8.9 07/14/2005 17:30:00 11.1 0.9 13.3 8.4 10.5 1.1 13 7.2 200 4 199 305 8.9 0 9.2 8.9 07/14/2005 17:40:00 10.8 0.6 12.6 9.1 10.4 0.7 12.2 8.8 203 4 197 305 8.8 0 8.9 8.7 07/14/2005 17:50:00 10.7 0.8 12.6 8.4 10.3 0.9 12.2 7.6 201 4 201 305 8.7 0 8.9 8.4 07/14/2005 18:00:00 10.6 0.6 12.2 9.1 10.3 0.7 11.8 8.4 202 4 197 305 8.7 0 8.9 8.7 07/14/2005 18:10:00 10.3 0.6 11.8 8.8 10 0.7 11.8 8 201 4 205 305 8.6 0 8.7 8.4 07/14/2005 18:20:00 10.7 0.7 12.2 8.8 10.3 0.9 11.8 7.2 199 4 203 305 8.5 0 8.7 8.2 07/14/2005 18:30:00 9.8 0.8 11.8 5.7 9.4 0.9 11.1 6.5 197 5 204 305 8.6 0 8.7 8.4 07/14/2005 18:40:00 10.2 0.8 11.8 7.6 9.9 0.9 11.8 6.5 196 4 199 305 8.6 0 8.9 8.4 07/14/2005 18:50:00 10.3 0.9 12.2 7.2 9.9 1 12.2 7.2 195 4 201 305 8.7 0 8.9 8.7 07/14/2005 19:00:00 10.4 0.8 11.8 8 10.1 0.9 11.8 6.8 198 4 196 305 8.5 0 8.7 8.4 07/14/2005 19:10:00 10.2 0.9 12.2 7.2 10 1.1 11.8 7.2 195 4 194 305 8.6 0 8.9 8.4 07/14/2005 19:20:00 10.7 0.9 13.3 8 10.5 1 13.3 8 192 4 198 305 8.9 0 9.2 8.7 07/14/2005 19:30:00 10.8 0.8 12.6 8 10.5 1 12.6 7.2 196 3 198 305 8.9 0 9.2 8.9 07/14/2005 19:40:00 11.3 0.8 13 8.8 11 1 13 8 196 5 190 305 8.9 0 9.2 8.9 07/14/2005 19:50:00 10.4 0.9 12.2 7.6 10.1 1 12.6 6.5 195 4 194 305 8.8 0 8.9 8.7 07/14/2005 20:00:00 10.1 0.7 11.5 7.6 9.8 0.8 11.8 7.2 193 4 196 305 8.7 0 8.9 8.7 07/14/2005 20:10:00 9.4 0.9 11.1 6.8 9.3 1 11.1 6.8 189 5 192 305 8.8 0 9.2 8.7 07/14/2005 20:20:00 7.5 0.9 10.3 4.2 8 0.8 10.3 6.1 184 5 187 305 8.9 0 9.2 8.9 07/14/2005 20:30:00 7 1.1 9.5 4.2 8.3 0.8 9.9 6.1 179 5 186 305 8.9 0 9.2 8.7 07/14/2005 20:40:00 7.3 1.1 9.9 4.2 8.3 0.9 9.9 5.7 181 6 186 305 8.8 0 8.9 8.7 07/14/2005 20:50:00 7.4 1 9.5 4.6 7.7 1 9.9 4.2 184 5 181 305 8.9 0 9.2 8.9 07/14/2005 21:00:00 7.4 1.1 9.5 4.6 7.8 0.9 9.9 5.7 185 5 190 305 8.9 0 9.2 8.9 07/14/2005 21:10:00 8.5 0.9 10.7 4.6 8.7 0.7 10.3 4.9 186 4 186 305 8.9 0 9.2 8.7 07/14/2005 21:20:00 7.7 0.9 9.5 4.6 8 0.8 10.3 4.9 187 6 194 305 8.9 0 9.2 8.9 07/14/2005 21:30:00 6.3 1.1 8.8 3.4 7 0.8 9.1 5.3 182 6 192 305 8.9 0 9.2 8.9 07/14/2005 21:40:00 5.6 1 8.4 3 7.1 0.9 10.3 5.3 178 5 182 305 8.8 0 8.9 8.7 07/14/2005 21:50:00 5.5 1.2 8 2.6 6.6 0.7 8.4 4.6 179 7 183 305 8.8 0 8.9 8.9 07/14/2005 22:00:00 5.3 1 8 3 6.3 0.7 8 4.6 180 8 196 305 8.8 0 8.9 8.7 07/14/2005 22:10:00 5.3 1.1 8.8 2.6 6.3 0.7 8 3.8 179 7 177 305 8.8 0 8.9 8.7 07/14/2005 22:20:00 4.9 1 7.6 2.6 6.4 0.7 8.8 4.2 175 7 180 305 8.8 0 8.9 8.7 07/14/2005 22:30:00 4.9 0.9 8.8 3 6.6 0.7 8.4 4.9 174 7 185 305 8.8 0 9.2 8.7 07/14/2005 22:40:00 5.1 0.8 7.2 3.4 6.7 0.6 8.4 5.3 174 7 180 305 8.7 0 8.9 8.4 07/14/2005 22:50:00 5.3 0.9 8.8 3.4 7.3 0.6 8.8 5.3 174 7 185 305 8.6 0 8.9 8.4 07/14/2005 23:00:00 5.3 0.8 9.1 3.8 7.7 0.9 10.3 5.3 171 6 174 305 8.4 0 8.4 8.2 07/14/2005 23:10:00 5.6 0.9 8.8 3.8 7.9 0.8 10.3 5.7 172 6 160 305 8.3 0 8.4 8.2 07/14/2005 23:20:00 5.7 0.8 9.1 3.8 8.4 0.8 10.3 6.1 171 6 186 305 8.3 0 8.4 8.2 07/14/2005 23:30:00 6 0.8 8.8 4.2 8.8 0.8 11.5 6.8 171 6 192 305 8.3 0 8.4 8.2 07/14/2005 23:40:00 5.7 0.8 8.8 3.4 8.2 0.8 10.3 5.7 171 6 162 305 8.3 0 8.4 8.2 07/14/2005 23:50:00 5.5 0.7 7.6 3.8 8.5 0.8 9.9 6.1 170 5 172 305 8.3 0 8.4 8.2 07/15/2005 00:00:00 5.5 0.8 8 3.8 8.5 0.8 10.3 6.5 169 5 163 305 8.2 0 8.9 8.2 07/15/2005 00:10:00 5.5 0.8 8 3.8 7.9 0.8 9.9 5.7 168 6 172 305 8.2 0 8.4 8.2 07/15/2005 00:20:00 5.4 0.7 8 3.8 7.9 0.7 9.5 6.1 170 6 177 305 8.2 0 8.4 8.2 07/15/2005 00:30:00 5.3 0.7 7.6 3.4 7.7 0.8 9.5 5.7 170 6 162 305 8.2 0 8.4 8.2 07/15/2005 00:40:00 5.4 0.6 7.2 3.8 8.2 0.7 9.9 6.1 169 5 159 305 8.2 0 8.4 8.2 07/15/2005 00:50:00 5.1 0.7 8 3.8 7.6 0.7 9.1 5.7 169 5 158 305 8.2 0 8.4 8.2 07/15/2005 01:00:00 5.3 0.7 7.2 3.8 7.9 0.7 9.9 5.7 172 5 182 305 8.4 0 8.4 8.2 07/15/2005 01:10:00 5.6 1 8.4 3.8 7.9 0.6 9.5 6.1 174 6 180 305 8.4 0 8.4 8.2 07/15/2005 01:20:00 5.5 0.9 8.4 3.8 8.2 0.6 9.9 6.1 172 5 183 305 8.4 0 8.4 8.2 07/15/2005 01:30:00 5.5 1 8.4 3.8 7.8 0.7 9.5 5.7 174 6 183 305 8.4 0 8.4 8.2 07/15/2005 01:40:00 5.5 1.1 8.4 3.4 7.4 0.8 9.9 4.9 176 7 184 305 8.3 0 8.4 8.2 07/15/2005 01:50:00 5.7 0.9 8 3.8 7.8 0.7 9.5 6.5 174 6 186 305 8.4 0 8.4 8.2 07/15/2005 02:00:00 5.5 0.9 8 3.4 7.7 0.8 9.9 5.7 174 6 183 305 8.4 0 8.4 8.2 07/15/2005 02:10:00 5.4 1 8.4 3 7.3 0.7 8.8 5.3 176 6 193 305 8.4 0 8.4 8.2 07/15/2005 02:20:00 5.7 1.2 8 3 7.1 0.8 8.8 5.3 178 7 186 305 8.4 0 8.4 8.2 07/15/2005 02:30:00 5.8 1.2 8.4 3.4 7 0.8 9.1 5.3 179 6 184 305 8.4 0 8.4 8.2 07/15/2005 02:40:00 5.7 1.1 8.4 3.4 6.9 0.9 9.1 4.6 179 6 181 305 8.4 0 8.4 8.2 07/15/2005 02:50:00 6.3 0.9 8.4 4.2 7.4 0.6 8.8 5.3 180 5 184 305 8.3 0 8.4 8.2 07/15/2005 03:00:00 6.1 0.9 8 3.8 7.1 0.6 8 5.3 181 5 180 305 8.3 0 8.4 8.2 07/15/2005 03:10:00 6.2 1 8.8 3.4 7.6 0.8 9.5 5.3 179 5 182 305 8.3 0 8.4 8.2 07/15/2005 03:20:00 6.5 1 9.1 3.8 7.6 0.7 9.5 5.7 181 5 183 305 8.4 0 8.4 8.2 07/15/2005 03:30:00 6.2 0.9 8 3.8 7.3 0.6 8.8 5.7 181 5 188 305 8.4 0 8.4 8.2 07/15/2005 03:40:00 5.7 0.8 8 3.8 6.4 0.6 8.4 4.6 182 5 184 305 8.3 0 8.4 8.2 07/15/2005 03:50:00 5.8 0.8 8 3.8 6.3 0.6 8 4.9 183 5 187 305 8.2 0 8.4 8.2 07/15/2005 04:00:00 5.7 0.8 7.6 3.4 6.4 0.6 8 4.6 182 5 184 305 8.2 0 8.4 8.2 07/15/2005 04:10:00 6 0.8 7.6 3.4 6.6 0.6 8 4.9 183 5 194 305 8.2 0 8.4 8.2 07/15/2005 04:20:00 5.8 0.8 7.6 3.8 6.6 0.7 8.4 4.6 181 5 184 305 8.2 0 8.2 8.2 07/15/2005 04:30:00 6 0.8 7.6 3.8 7 0.6 8.4 5.3 180 5 186 305 8.2 0 8.4 8.2 07/15/2005 04:40:00 5.9 1 8 3.8 6.9 0.7 8.4 4.9 181 5 183 305 8.2 0 8.2 8.2 07/15/2005 04:50:00 6.3 0.7 8 4.2 7 0.7 8.8 5.3 182 4 180 305 8.2 0 8.2 8.2 07/15/2005 05:00:00 5.7 0.8 7.6 3.4 6.3 0.6 8 4.6 182 5 188 305 8.2 0 8.2 8.2 07/15/2005 05:10:00 5.9 0.8 8.8 4.2 7 0.7 9.1 5.3 181 5 192 305 8.2 0 8.2 8.2 07/15/2005 05:20:00 6.2 0.9 8.4 3.4 7.4 0.7 9.1 5.3 180 5 177 305 8.2 0 8.2 8.2 07/15/2005 05:30:00 6.4 0.8 8 3.8 7.2 0.7 8.8 4.9 182 5 186 305 8.2 0 8.4 8.2 07/15/2005 05:40:00 5.8 0.7 7.6 3.8 6.3 0.6 8 4.9 183 5 184 305 8.2 0 8.2 8.2 07/15/2005 05:50:00 6.1 0.9 8 3.4 6.5 0.7 8.4 4.6 184 5 183 305 8.2 0 8.4 8.2 07/15/2005 06:00:00 6.2 0.6 8 4.6 6.4 0.5 8 4.9 187 5 187 305 8.2 0 8.4 8.2 07/15/2005 06:10:00 6 0.7 7.6 4.2 6.2 0.6 8 4.6 186 5 183 305 8.2 0 8.4 8.2 07/15/2005 06:20:00 6.1 1 8.4 3.4 7.1 0.7 9.1 5.3 181 5 183 305 8.2 0 8.4 8.2 07/15/2005 06:30:00 5.9 1.1 8.4 3.4 7.2 0.8 9.1 4.9 179 6 184 305 8.2 0 8.4 8.2 07/15/2005 06:40:00 6 1.2 8.8 3 7.2 0.8 9.1 5.3 179 6 183 305 8.3 0 8.4 8.2 07/15/2005 06:50:00 5.8 1.1 8 3 6.9 0.7 8.4 4.9 180 6 190 305 8.3 0 8.4 8.2 07/15/2005 07:00:00 4.9 0.9 7.2 3 6.3 0.7 8.4 4.6 176 7 186 305 8.3 0 8.4 8.2 07/15/2005 07:10:00 4.5 0.7 6.8 3 6.6 0.6 8 4.9 170 6 176 305 8.3 0 8.4 8.2 07/15/2005 07:20:00 4.6 0.6 6.8 3 6.8 0.6 8.4 4.6 169 5 184 305 8.4 0 8.4 8.2 07/15/2005 07:30:00 4.7 0.8 7.2 3 6.6 0.7 8.4 4.6 169 6 167 305 8.4 0 8.4 8.2 07/15/2005 07:40:00 4.3 0.6 6.5 2.6 6.2 0.7 8 4.2 169 5 157 305 8.4 0 8.4 8.2 07/15/2005 07:50:00 4.3 0.6 6.8 2.6 6.1 0.8 8 4.2 168 6 175 305 8.4 0 8.4 8.2 07/15/2005 08:00:00 4.4 0.7 6.5 3 6 0.7 7.6 4.2 167 5 166 305 8.4 0 8.4 8.2 07/15/2005 08:10:00 4.3 0.6 6.8 2.6 6.5 0.8 8.4 4.6 169 5 158 305 8.4 0 8.7 8.2 07/15/2005 08:20:00 4.6 0.8 6.5 2.6 6.9 0.8 8.8 5.3 172 6 174 305 8.5 0 8.7 8.4 07/15/2005 08:30:00 4.9 0.8 7.6 3.4 7.1 0.8 8.8 5.7 172 6 163 305 8.5 0 8.7 8.4 07/15/2005 08:40:00 4.6 0.8 7.2 3 6.6 0.8 8.8 4.6 172 7 188 305 8.5 0 8.7 8.4 07/15/2005 08:50:00 5 0.9 8.4 3 6.9 0.9 9.1 4.9 172 7 159 305 8.5 0 8.7 8.4 07/15/2005 09:00:00 4.7 0.8 6.8 2.6 6.2 0.9 8.8 4.2 174 7 167 305 8.6 0 8.9 8.4 07/15/2005 09:10:00 4.6 0.9 7.6 3 6.2 0.7 7.6 4.2 173 8 157 305 8.7 0 8.9 8.4 07/15/2005 09:20:00 5 1 9.1 2.6 7 0.9 9.9 4.6 170 6 158 305 8.7 0 8.9 8.4 07/15/2005 09:30:00 4.8 1 7.2 2.3 6.4 0.9 8.8 4.6 173 7 187 305 8.8 0 8.9 8.7 07/15/2005 09:40:00 4.8 0.7 6.8 3 7 0.8 9.1 4.9 168 5 169 305 8.7 0 8.9 8.7 07/15/2005 09:50:00 5.2 0.8 8.4 3.4 7.8 0.8 9.1 4.9 170 5 165 305 8.7 0 8.9 8.7 07/15/2005 10:00:00 5 0.6 6.8 3.4 7.7 0.7 9.5 5.3 169 6 158 305 8.8 0 8.9 8.7 07/15/2005 10:10:00 5.3 0.8 8.4 3.8 7.9 0.7 9.9 5.7 169 5 165 305 8.8 0 8.9 8.7 07/15/2005 10:20:00 5.5 0.8 8.4 3.8 8.2 0.8 10.3 6.1 171 6 160 305 8.9 0 9.2 8.9 07/15/2005 10:30:00 5 1 7.6 3 6.8 0.7 8.8 5.3 171 7 162 305 9 0 9.2 8.9 07/15/2005 10:40:00 4.8 0.8 7.2 3 6.9 0.7 8.8 4.6 171 6 169 305 9.1 0 9.2 8.9 07/15/2005 10:50:00 5.2 1.1 8 3 6.6 0.7 8.4 4.2 176 7 187 305 9.2 0 9.5 9.2 07/15/2005 11:00:00 5.2 1.2 8 3 6.7 0.9 8.8 4.6 177 7 186 305 9.3 0 9.5 9.2 07/15/2005 11:10:00 5.2 1 8.4 3 7.3 0.7 9.5 5.3 168 6 174 305 9.3 0 9.5 9.2 07/15/2005 11:20:00 5 0.9 7.6 3.4 7 0.8 9.1 4.9 171 6 169 305 9.3 0 9.5 9.2 07/15/2005 11:30:00 4.6 0.9 6.8 2.6 5.9 0.6 7.2 4.2 175 7 168 305 9.5 0 9.7 9.2 07/15/2005 11:40:00 4.7 1 7.2 2.3 5.9 0.7 7.6 3.8 175 8 183 305 9.6 0 9.7 9.5 07/15/2005 11:50:00 5.1 1 7.2 3.4 6.6 0.6 8.8 4.6 175 7 177 305 9.7 0 9.7 9.5 07/15/2005 12:00:00 4.9 1 7.2 3 6.3 0.8 8.4 4.2 173 7 178 305 9.7 0 9.7 9.7 07/15/2005 12:10:00 6.1 1.5 9.9 2.6 7.5 1.1 10.7 4.9 178 7 179 305 9.7 0 9.7 9.5 07/15/2005 12:20:00 6.5 1.2 9.1 3.4 7.6 0.9 9.5 4.9 181 6 188 305 9.3 0 9.5 9.2 07/15/2005 12:30:00 5.3 1.1 8 3 7 0.7 8.8 5.3 175 7 176 305 9.5 0 9.7 9.2 07/15/2005 12:40:00 4.6 0.8 6.5 3 6.4 0.7 8 4.6 172 6 166 305 9.7 0 10 9.7 07/15/2005 12:50:00 4.5 0.8 6.8 3 6.4 0.7 9.1 4.6 169 5 169 305 9.7 0 10 9.7 07/15/2005 13:00:00 4.5 0.9 8 3 6.5 0.6 8 4.6 169 5 158 305 9.8 0 10 9.7 07/15/2005 13:10:00 5.7 1.3 8 2.3 6.8 1 8.4 4.2 179 6 181 305 9.9 0 10.2 9.7 07/15/2005 13:20:00 5 0.9 7.2 3 7 0.8 8.8 4.6 172 7 183 305 9.9 0 10.2 9.7 07/15/2005 13:30:00 4.8 1 6.8 2.6 6.3 0.8 8.4 4.2 174 7 186 305 9.9 0 10 9.7 07/15/2005 13:40:00 4.7 0.9 7.2 2.6 6.4 0.8 8 4.9 173 7 183 305 9.7 0 9.7 9.5 07/15/2005 13:50:00 4.4 0.8 6.8 2.6 6 0.7 7.6 4.2 171 7 158 305 9.7 0 10 9.5 07/15/2005 14:00:00 4.5 0.9 6.8 2.6 6.3 0.6 8 4.6 173 6 183 305 9.9 0 10 9.7 07/15/2005 14:10:00 4.6 0.8 6.8 3 6.3 0.6 8 4.6 173 6 181 305 10 0 10.2 10 07/15/2005 14:20:00 4.5 0.8 6.5 3 6.3 0.6 8 4.9 172 6 159 305 10 0 10.2 10 07/15/2005 14:30:00 4.7 1 6.8 2.3 5.9 0.7 7.6 4.2 177 7 192 305 10.2 0 10.2 10 07/15/2005 14:40:00 4.9 1 6.5 2.6 5.6 0.6 6.8 3.8 182 6 189 305 10.3 0 10.5 10.2 07/15/2005 14:50:00 5.2 1.1 6.8 2.3 5.9 0.7 7.2 3.8 183 6 189 305 10.5 0.1 11 10.2 07/15/2005 15:00:00 4.5 0.8 7.2 2.6 6.3 0.5 7.6 4.9 176 6 186 305 10.6 0 11 10.5 07/15/2005 15:10:00 5 0.8 6.8 3.4 4.9 1.1 7.2 2.6 203 13 186 305 10.4 0.2 11.3 10 07/15/2005 15:20:00 4.8 0.5 6.1 3 4.4 0.5 5.7 2.6 211 6 208 305 10 0 10.5 10 07/15/2005 15:30:00 3.9 0.6 5.3 2.3 3.5 0.5 4.9 2.3 207 7 207 305 10 0 10.5 9.7 07/15/2005 15:40:00 3 0.6 4.6 1.5 2.6 0.6 4.6 1.5 210 11 207 305 9.9 0 10.2 9.7 07/15/2005 15:50:00 3 0.5 4.2 1.5 2.8 0.5 3.8 1.1 196 12 194 305 9.7 0 10.2 9.5 07/15/2005 16:00:00 2.8 0.5 3.8 1.5 2.8 0.4 3.8 1.9 193 9 192 305 9.6 0 10.2 9.5 07/15/2005 16:10:00 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.1 192 8 200 305 9.5 0 10.2 9.5 07/15/2005 16:20:00 2.4 0.4 3.4 1.5 2.5 0.3 3.4 1.5 187 6 196 305 9.5 0 10.2 9.5 07/15/2005 16:30:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 188 6 189 305 9.6 0 10.2 9.5 07/15/2005 16:40:00 2.8 0.6 4.2 1.5 3 0.6 4.6 1.9 173 17 139 305 9.4 0 10 9.2 07/15/2005 16:50:00 2 1 5.3 0.4 2.1 1 5.7 0.4 191 19 159 305 9.5 0 9.7 9.2 07/15/2005 17:00:00 1.2 0.4 2.3 0.4 1.3 0.4 2.3 0.4 196 11 208 305 9.4 0 9.5 9.2 07/15/2005 17:10:00 1.1 0.4 2.3 0.4 1 0.4 1.9 0.4 206 18 207 305 9.5 0 9.7 9.5 07/15/2005 17:20:00 1.3 0.5 2.3 0.4 1.3 0.5 2.3 0.4 210 8 213 305 9.5 0 9.5 9.5 07/15/2005 17:30:00 1.8 0.4 2.6 0.7 1.7 0.5 2.6 0.7 202 8 205 305 9.5 0 9.7 9.2 07/15/2005 17:40:00 1 0.4 1.9 0.4 1 0.4 1.9 0.4 206 13 190 305 9.5 0 9.7 9.5 07/15/2005 17:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 193 1 192 305 9.6 0 9.7 9.5 07/15/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 191 2 305 305 9.8 0 10 9.7 07/15/2005 18:10:00 0.5 0.2 1.5 0.4 0.7 0.5 1.9 0.4 86 112 332 305 9.9 0 10 9.7 07/15/2005 18:20:00 0.5 0.3 1.9 0.4 1 0.4 1.9 0.4 337 19 59 305 9.4 0.1 9.7 9.2 07/15/2005 18:30:00 1.4 0.5 2.3 0.4 1.7 0.5 2.6 0.7 10 18 8 305 9.1 0 9.5 8.9 07/15/2005 18:40:00 0.6 0.3 1.5 0.4 1 0.4 1.5 0.4 5 14 9 305 9.1 0 9.7 8.9 07/15/2005 18:50:00 1.3 0.5 2.6 0.4 1.5 0.6 3 0.7 43 19 12 305 9.4 0.1 10 9.2 07/15/2005 19:00:00 1.8 0.5 3 0.7 1.9 0.6 3.4 0.7 3 4 5 305 9.1 0 9.7 8.9 07/15/2005 19:10:00 0.7 0.3 1.9 0.4 1 0.3 1.5 0.4 13 12 17 305 9.3 0.1 10 9.2 07/15/2005 19:20:00 1.3 0.5 2.3 0.4 1.4 0.4 2.6 0.4 6 7 351 305 9.4 0.1 10 9.2 07/15/2005 19:30:00 2.8 0.5 3.8 1.1 2.8 0.5 3.8 1.5 34 13 48 305 8.9 0.1 9.7 8.9 07/15/2005 19:40:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 50 6 44 305 9.2 0 9.7 8.9 07/15/2005 19:50:00 4 0.2 4.6 3.8 4 0.2 4.6 3.4 48 1 47 305 9.3 0.1 10 9.2 07/15/2005 20:00:00 3.9 0.2 4.6 3.4 3.8 0.2 4.6 3.4 50 4 43 305 9.2 0 9.7 8.9 07/15/2005 20:10:00 3.5 0.3 4.2 2.3 3.5 0.4 4.2 2.3 61 8 56 305 9.3 0.1 10 9.2 07/15/2005 20:20:00 3.5 0.4 4.2 2.6 3.5 0.4 4.2 2.3 51 2 51 305 9.5 0.1 10 9.2 07/15/2005 20:30:00 3.5 0.4 4.2 2.6 3.6 0.3 4.2 2.6 48 4 48 305 9.2 0 10 8.9 07/15/2005 20:40:00 3.5 0.2 4.2 3 3.7 0.2 4.2 3.4 44 3 44 305 8.8 0 9.2 8.7 07/15/2005 20:50:00 3.9 0.5 4.9 2.6 3.8 0.6 4.9 2.3 61 13 48 305 8.8 0.2 9.7 8.4 07/15/2005 21:00:00 3.8 0.4 4.6 2.3 3.6 0.4 4.6 2.6 56 7 54 305 9.1 0.3 9.7 8.9 07/15/2005 21:10:00 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.6 58 8 67 305 8.9 0 9.5 8.9 07/15/2005 21:20:00 3.9 0.5 4.9 2.6 4.1 0.5 4.9 2.6 52 5 54 305 8.9 0.1 9.7 8.7 07/15/2005 21:30:00 4 0.4 4.9 3 3.8 0.4 4.9 2.6 75 12 56 305 9 0.2 9.5 8.4 07/15/2005 21:40:00 3.6 0.5 5.3 2.6 3.5 0.4 4.6 2.6 64 8 70 305 9.2 0.2 9.7 8.7 07/15/2005 21:50:00 3.8 0.4 4.6 2.6 3.7 0.4 4.6 2.6 61 4 72 305 8.7 0 8.9 8.4 07/15/2005 22:00:00 3.7 0.4 4.6 2.6 3.6 0.4 4.6 3 61 4 56 305 8.6 0 8.9 8.4 07/15/2005 22:10:00 3.5 0.4 4.6 2.6 3.4 0.4 4.2 2.3 63 6 55 305 8.8 0 8.9 8.4 07/15/2005 22:20:00 3.3 0.4 4.2 2.3 3.1 0.4 4.2 2.3 66 8 80 305 8.8 0 8.9 8.7 07/15/2005 22:30:00 3.6 0.3 4.6 2.6 3.7 0.3 4.6 3 60 5 56 305 8.6 0 8.9 8.2 07/15/2005 22:40:00 3.8 0.5 4.9 2.6 3.4 0.5 4.6 2.3 76 6 72 305 8.4 0.1 8.9 8.2 07/15/2005 22:50:00 4.2 0.3 4.9 3.4 4 0.4 4.9 3 73 5 70 305 9.2 0.1 9.5 8.9 07/15/2005 23:00:00 3.7 0.5 4.9 2.3 3.5 0.4 4.2 2.3 70 7 64 305 9.3 0 9.5 9.2 07/15/2005 23:10:00 4.6 0.4 5.7 3.4 4.2 0.4 5.3 3 83 6 86 305 9.1 0 9.5 8.9 07/15/2005 23:20:00 4.3 0.5 5.7 3.4 3.9 0.5 4.9 3 85 7 65 305 8.9 0 9.2 8.7 07/15/2005 23:30:00 3.7 0.5 4.6 2.3 3.3 0.6 4.6 1.5 83 8 82 305 8.7 0 8.9 8.4 07/15/2005 23:40:00 2.7 0.5 3.8 1.5 2.8 0.5 3.8 1.5 55 13 80 305 8.1 0.3 8.7 7.7 07/15/2005 23:50:00 3.3 0.2 3.8 3 3.4 0.2 3.8 3 40 5 42 305 7.5 0 7.7 7.4 07/16/2005 00:00:00 3.3 0.2 3.8 3 3.4 0.2 3.8 3 39 5 33 305 7.2 0.1 7.9 7.2 07/16/2005 00:10:00 3.1 0.2 3.4 2.6 3.3 0.2 3.8 3 31 10 48 305 7 0 7.2 6.9 07/16/2005 00:20:00 3.1 0.2 3.4 2.6 3.4 0.2 3.8 3 17 3 15 305 7 0 7.2 6.9 07/16/2005 00:30:00 3.1 0.2 3.4 2.6 3.4 0.1 3.8 3 16 2 22 305 6.9 0 7.2 6.9 07/16/2005 00:40:00 3.1 0.2 3.4 2.6 3.4 0.2 3.8 3 21 3 16 305 7 0 7.2 6.9 07/16/2005 00:50:00 3.4 0.2 3.8 3 3.4 0.2 3.8 3 26 2 24 305 6.8 0 7.2 6.7 07/16/2005 01:00:00 3.5 0.2 3.8 3 3.5 0.2 3.8 3 25 2 26 305 6.8 0 7.2 6.9 07/16/2005 01:10:00 3.6 0.2 4.2 3 3.8 0.2 4.2 3.4 25 3 24 305 7 0 7.2 6.9 07/16/2005 01:20:00 3.6 0.2 3.8 3 3.8 0.2 4.2 3.4 26 2 25 305 7 0 7.2 6.9 07/16/2005 01:30:00 3.7 0.2 4.2 3 3.7 0.2 4.2 3 27 2 26 305 6.9 0 7.2 6.9 07/16/2005 01:40:00 3.6 0.2 4.2 3 3.7 0.2 4.2 3.4 20 3 22 305 6.9 0 7.2 6.9 07/16/2005 01:50:00 3.1 0.2 3.4 2.6 3.5 0.2 3.8 3 15 3 14 305 7 0 7.2 6.9 07/16/2005 02:00:00 3.2 0.2 3.4 3 3.5 0.2 3.8 3.4 11 2 10 305 7 0 7.2 6.9 07/16/2005 02:10:00 3.1 0.2 3.4 2.6 3 0.2 3.8 2.6 14 2 15 305 7 0 7.2 6.9 07/16/2005 02:20:00 2.8 0.3 3.4 1.9 2.6 0.3 3 1.9 16 4 13 305 7.1 0 7.4 6.9 07/16/2005 02:30:00 2.7 0.2 3.4 1.9 2.6 0.2 3 1.9 18 3 18 305 7.2 0 7.4 7.2 07/16/2005 02:40:00 2.5 0.2 3 1.9 2.5 0.2 3 1.9 26 4 21 305 7.2 0 7.4 7.2 07/16/2005 02:50:00 2.3 0.2 2.6 1.9 2.2 0.2 3 1.9 22 3 23 305 7.1 0 7.4 7.2 07/16/2005 03:00:00 2.2 0.2 2.6 1.9 2.2 0.2 2.6 1.9 18 3 24 305 7.2 0 7.4 7.2 07/16/2005 03:10:00 2.2 0.3 2.6 1.5 2.1 0.3 2.6 1.5 15 4 12 305 7.2 0 7.4 7.2 07/16/2005 03:20:00 2.2 0.4 3 1.1 2.1 0.3 2.6 1.5 4 7 8 305 7.2 0 7.4 7.2 07/16/2005 03:30:00 2.5 0.5 3.4 1.1 2.3 0.4 3 1.5 4 5 6 305 7.3 0 7.4 7.2 07/16/2005 03:40:00 2.9 0.4 3.8 1.5 2.6 0.4 3.4 1.9 5 3 7 305 7.3 0 7.4 7.2 07/16/2005 03:50:00 2.3 0.6 3.4 1.5 2 0.5 3 0.7 4 7 4 305 7.3 0 7.7 7.2 07/16/2005 04:00:00 3.2 1 4.2 0.7 2.8 1 4.2 0.7 352 7 347 305 7.2 0.1 7.4 7.2 07/16/2005 04:10:00 4.2 0.3 4.9 3.8 4.1 0.2 4.9 3.4 346 3 347 305 7.1 0 7.4 7.2 07/16/2005 04:20:00 4.8 0.3 5.7 4.2 4.7 0.3 5.7 4.2 348 3 352 305 7.4 0 7.7 7.2 07/16/2005 04:30:00 5.2 0.2 5.7 4.6 5.1 0.2 5.7 4.6 352 2 351 305 7.6 0 7.7 7.4 07/16/2005 04:40:00 5.4 0.2 6.1 4.9 5.3 0.2 6.1 4.6 347 2 344 305 7.7 0 7.7 7.7 07/16/2005 04:50:00 5.7 0.4 6.5 4.6 5.7 0.4 6.8 4.6 347 3 346 305 7.6 0 7.7 7.4 07/16/2005 05:00:00 5.5 0.4 6.5 4.6 5.5 0.4 6.5 4.6 352 2 353 305 7.3 0 7.7 7.2 07/16/2005 05:10:00 5.2 0.3 6.1 4.6 5.2 0.3 6.1 4.6 353 2 350 305 7.3 0 7.4 7.2 07/16/2005 05:20:00 5.1 0.2 5.7 4.6 5.1 0.3 5.7 4.6 357 2 353 305 7.3 0 7.4 7.2 07/16/2005 05:30:00 5.2 0.3 6.1 4.6 5.1 0.3 5.7 4.2 356 2 355 305 7.3 0 7.4 7.2 07/16/2005 05:40:00 5.3 0.3 6.1 4.6 5.3 0.3 6.1 4.6 356 2 0 305 7.3 0 7.7 7.2 07/16/2005 05:50:00 5.5 0.3 6.1 4.9 5.5 0.3 6.5 4.6 356 2 359 305 7.4 0 7.7 7.4 07/16/2005 06:00:00 5 0.3 5.7 4.2 5.1 0.3 5.7 4.2 0 3 357 305 7.5 0 7.7 7.4 07/16/2005 06:10:00 4.7 0.3 5.3 4.2 4.7 0.3 5.3 3.8 1 2 358 305 7.5 0 7.7 7.4 07/16/2005 06:20:00 4.9 0.2 5.7 4.2 5 0.3 5.7 4.6 7 4 1 305 7.5 0 7.7 7.4 07/16/2005 06:30:00 4.8 0.2 5.3 4.2 4.7 0.2 5.3 4.2 13 3 8 305 7.5 0 7.7 7.4 07/16/2005 06:40:00 4.9 0.3 5.7 4.2 4.8 0.3 5.7 4.2 16 3 16 305 7.5 0 7.7 7.4 07/16/2005 06:50:00 5.1 0.3 6.1 4.2 5 0.3 6.1 4.2 12 4 11 305 7.6 0 7.7 7.4 07/16/2005 07:00:00 5.3 0.3 6.1 4.6 5.2 0.3 5.7 4.6 13 3 13 305 7.7 0 7.7 7.7 07/16/2005 07:10:00 5.2 0.3 5.7 4.6 5.1 0.3 6.1 4.2 12 3 10 305 7.7 0 7.7 7.7 07/16/2005 07:20:00 5 0.3 5.7 4.2 4.9 0.3 5.7 3.8 8 3 12 305 7.7 0 7.9 7.7 07/16/2005 07:30:00 4.7 0.4 5.7 4.2 4.7 0.4 5.3 3.8 8 3 12 305 7.7 0 7.9 7.7 07/16/2005 07:40:00 4.4 0.4 5.3 3.8 4.3 0.4 5.7 3.4 4 4 1 305 7.8 0 7.9 7.7 07/16/2005 07:50:00 5.4 0.4 6.1 4.6 5.4 0.4 6.5 4.6 3 3 10 305 7.7 0 7.9 7.7 07/16/2005 08:00:00 5 0.4 6.1 4.2 4.9 0.4 5.7 3.8 6 4 3 305 7.7 0 7.9 7.7 07/16/2005 08:10:00 4.9 0.3 5.7 4.2 4.9 0.4 6.1 3.8 2 4 4 305 7.7 0 7.9 7.7 07/16/2005 08:20:00 5.5 0.3 6.5 4.6 5.4 0.4 6.5 4.6 359 4 358 305 7.7 0 7.9 7.7 07/16/2005 08:30:00 4.6 0.5 5.7 3.4 4.5 0.5 5.7 3.4 5 5 357 305 7.7 0 7.9 7.7 07/16/2005 08:40:00 4.3 0.4 5.3 3.4 4.1 0.4 5.3 3 9 4 13 305 7.8 0 7.9 7.7 07/16/2005 08:50:00 4.1 0.4 4.9 3.4 4 0.4 4.9 3 14 4 18 305 8 0 8.2 7.9 07/16/2005 09:00:00 4.5 0.4 5.3 3 4.3 0.4 5.3 3 19 6 17 305 8.2 0 8.4 7.9 07/16/2005 09:10:00 4.9 0.3 5.7 3.8 4.6 0.4 5.7 3.8 24 4 22 305 8.4 0 8.4 8.2 07/16/2005 09:20:00 4.9 0.3 5.7 3.8 4.6 0.4 5.7 3.4 26 3 27 305 8.5 0 8.7 8.2 07/16/2005 09:30:00 5.4 0.5 6.5 4.2 5.2 0.6 6.5 3.4 24 4 21 305 8.4 0 8.7 8.2 07/16/2005 09:40:00 5.4 0.4 6.5 4.6 5.3 0.4 6.1 4.2 18 3 18 305 8.3 0 8.4 8.2 07/16/2005 09:50:00 5.6 0.3 6.5 4.6 5.5 0.4 6.5 4.2 15 3 16 305 8.2 0 8.4 8.2 07/16/2005 10:00:00 5.8 0.3 6.5 4.9 5.7 0.4 6.8 4.6 10 3 16 305 8.2 0 8.4 8.2 07/16/2005 10:10:00 6 0.3 6.8 5.3 5.9 0.3 6.5 4.9 6 3 8 305 8.2 0 8.4 8.2 07/16/2005 10:20:00 6 0.4 7.2 5.3 5.9 0.5 7.2 4.6 7 3 4 305 8.3 0 8.4 8.2 07/16/2005 10:30:00 6.3 0.3 6.8 5.3 6.1 0.4 7.2 4.9 9 3 11 305 8.3 0 8.4 8.2 07/16/2005 10:40:00 6.1 0.3 6.8 5.3 6 0.4 6.8 4.9 10 3 4 305 8.4 0 8.4 8.2 07/16/2005 10:50:00 5.8 0.4 6.8 4.9 5.6 0.4 6.8 4.6 8 4 7 305 8.4 0 8.4 8.2 07/16/2005 11:00:00 5.9 0.5 7.2 4.6 5.8 0.5 7.2 4.6 3 3 2 305 8.4 0 8.7 8.2 07/16/2005 11:10:00 6.4 0.4 7.6 5.7 6.3 0.4 7.2 5.3 2 3 5 305 8.4 0 8.7 8.2 07/16/2005 11:20:00 6.6 0.3 7.2 5.7 6.4 0.4 7.2 5.7 10 3 11 305 8.4 0 8.7 8.2 07/16/2005 11:30:00 7.1 0.5 8.4 5.7 7 0.6 8.4 4.9 11 4 11 305 8.4 0 8.4 8.2 07/16/2005 11:40:00 7.6 0.5 8.8 6.1 7.6 0.6 9.1 5.7 9 4 12 305 8.2 0 8.4 7.9 07/16/2005 11:50:00 7.8 0.5 8.8 6.5 7.7 0.5 8.8 6.5 10 3 6 305 7.9 0 8.2 7.7 07/16/2005 12:00:00 7.4 0.4 8.4 6.5 7.3 0.5 8.4 5.7 9 3 12 305 7.8 0 7.9 7.7 07/16/2005 12:10:00 7.7 0.5 9.1 6.5 7.5 0.4 8.4 6.1 10 4 16 305 7.9 0 8.2 7.7 07/16/2005 12:20:00 8 0.5 9.1 6.1 7.9 0.5 9.1 6.5 13 3 16 305 8 0 8.2 7.9 07/16/2005 12:30:00 8.6 0.5 9.9 7.2 8.5 0.5 9.5 7.2 14 3 10 305 8.2 0 8.4 7.9 07/16/2005 12:40:00 8.4 0.7 9.9 6.8 8.2 0.7 9.9 6.5 16 3 14 305 8.1 0 8.4 7.9 07/16/2005 12:50:00 7.7 0.5 9.5 6.1 7.5 0.5 9.1 6.1 15 3 25 305 8 0 8.2 7.9 07/16/2005 13:00:00 7.2 0.5 8.4 6.1 7.1 0.5 8.4 5.3 12 3 16 305 8.1 0 8.2 7.9 07/16/2005 13:10:00 6.8 0.5 8 5.7 6.6 0.5 8 5.3 13 3 14 305 8.2 0 8.2 8.2 07/16/2005 13:20:00 6.4 0.4 7.2 5.3 6.3 0.4 7.2 4.9 13 3 12 305 8.2 0 8.4 7.9 07/16/2005 13:30:00 6.7 0.4 7.6 5.3 6.6 0.5 7.6 4.9 10 3 14 305 8.2 0.1 8.4 7.9 07/16/2005 13:40:00 6.8 0.5 8 5.7 6.6 0.5 7.6 4.9 5 4 1 305 8.2 0 8.4 8.2 07/16/2005 13:50:00 6.9 0.4 8 5.7 6.8 0.5 8 4.9 5 3 4 305 8.1 0 8.4 7.9 07/16/2005 14:00:00 6.9 0.5 8.4 5.7 6.7 0.5 8 5.3 6 4 3 305 8 0 8.2 7.9 07/16/2005 14:10:00 7.2 0.5 8.4 5.7 7.2 0.6 8.4 5.3 8 3 7 305 7.9 0 8.2 7.7 07/16/2005 14:20:00 6.5 0.4 7.6 5.7 6.4 0.5 7.6 4.9 9 3 4 305 7.9 0 8.2 7.7 07/16/2005 14:30:00 6.7 0.5 8.4 5.3 6.6 0.5 8 5.3 13 4 11 305 8 0 8.2 7.9 07/16/2005 14:40:00 6.4 0.4 7.6 5.3 6.2 0.5 7.2 4.9 14 3 13 305 8 0 8.2 7.7 07/16/2005 14:50:00 5.7 0.4 6.8 4.6 5.6 0.4 6.5 4.6 16 3 20 305 8 0 8.2 7.9 07/16/2005 15:00:00 5.9 0.4 6.8 4.9 5.7 0.4 6.8 4.6 16 3 12 305 8 0 8.2 7.9 07/16/2005 15:10:00 6.2 0.4 7.2 5.3 6 0.4 6.8 4.9 16 4 14 305 8 0 8.2 7.9 07/16/2005 15:20:00 6.6 0.5 7.6 5.7 6.4 0.5 7.6 4.9 21 3 21 305 8 0 8.4 7.9 07/16/2005 15:30:00 5.9 0.5 6.8 4.9 5.8 0.5 6.8 4.6 26 4 26 305 7.8 0 7.9 7.7 07/16/2005 15:40:00 5.4 0.5 6.8 4.2 5.3 0.4 6.5 4.2 28 4 24 305 7.7 0 7.9 7.7 07/16/2005 15:50:00 5.7 0.4 6.8 4.6 5.6 0.4 6.5 4.6 29 3 32 305 7.7 0 7.9 7.7 07/16/2005 16:00:00 5.9 0.5 6.8 4.6 5.7 0.5 6.8 4.6 31 3 28 305 7.6 0 7.7 7.4 07/16/2005 16:10:00 5.2 0.3 6.1 4.6 5.1 0.4 6.1 4.2 34 3 33 305 7.6 0 7.7 7.4 07/16/2005 16:20:00 4.9 0.4 5.7 3.8 4.8 0.4 5.7 3.8 37 4 33 305 7.5 0 7.7 7.4 07/16/2005 16:30:00 5.2 0.2 6.1 4.9 5.1 0.3 5.7 4.2 39 3 39 305 7.5 0 7.7 7.4 07/16/2005 16:40:00 5.2 0.3 5.7 4.2 5 0.3 5.7 4.2 39 3 40 305 7.5 0 7.7 7.4 07/16/2005 16:50:00 5.3 0.3 6.1 4.6 5.1 0.3 5.7 4.6 41 3 38 305 7.5 0 7.7 7.4 07/16/2005 17:00:00 5.7 0.3 6.5 4.9 5.5 0.3 6.5 4.6 45 3 45 305 7.5 0 7.7 7.4 07/16/2005 17:10:00 5.6 0.3 6.1 4.6 5.4 0.4 6.1 4.2 49 4 46 305 7.4 0 7.7 7.4 07/16/2005 17:20:00 5.1 0.5 6.1 3.4 5.1 0.5 6.1 3.4 48 6 47 305 7.4 0 7.7 7.2 07/16/2005 17:30:00 4.7 0.3 5.3 3.8 4.7 0.4 5.7 3.4 44 5 43 305 7.3 0 7.7 7.2 07/16/2005 17:40:00 4 0.4 4.9 3.4 4 0.4 4.9 3.4 39 3 38 305 7.3 0 7.7 7.2 07/16/2005 17:50:00 3.5 0.3 4.2 3 3.3 0.3 4.2 2.6 32 6 30 305 7.3 0 7.4 7.2 07/16/2005 18:00:00 2.8 0.3 3.4 2.3 2.7 0.3 3.4 1.9 22 4 23 305 7.3 0 7.7 7.2 07/16/2005 18:10:00 2.7 0.2 3 2.3 2.7 0.2 3 1.9 8 5 13 305 7.3 0 7.7 7.4 07/16/2005 18:20:00 2.9 0.2 3.4 2.3 2.9 0.3 3.4 1.9 356 3 359 305 7.5 0 7.7 7.4 07/16/2005 18:30:00 2.5 0.2 3 1.9 2.5 0.2 3 1.9 343 6 352 305 7.5 0 7.7 7.4 07/16/2005 18:40:00 2.5 0.3 3 1.9 2.5 0.3 3 1.5 328 4 326 305 7.5 0 7.7 7.4 07/16/2005 18:50:00 2.6 0.3 3 1.9 2.6 0.3 3 1.9 321 5 331 305 7.5 0 7.7 7.4 07/16/2005 19:00:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 315 5 310 305 7.5 0 7.7 7.4 07/16/2005 19:10:00 2.5 0.4 3 1.5 2.5 0.3 3 1.9 319 5 318 305 7.5 0 7.7 7.4 07/16/2005 19:20:00 2.3 0.3 2.6 1.5 2.3 0.3 3 1.5 329 6 319 305 7.5 0 7.7 7.4 07/16/2005 19:30:00 2.2 0.3 2.6 1.1 2.1 0.4 3 1.1 326 4 327 305 7.5 0 7.7 7.4 07/16/2005 19:40:00 2.2 0.3 2.6 1.5 2 0.3 2.6 1.1 327 5 326 305 7.6 0 7.7 7.4 07/16/2005 19:50:00 2 0.2 2.6 1.5 1.9 0.3 2.6 1.1 325 4 326 305 7.6 0 7.7 7.7 07/16/2005 20:00:00 1.7 0.2 2.3 1.1 1.4 0.3 2.3 0.7 331 4 333 305 7.6 0 7.7 7.7 07/16/2005 20:10:00 1.5 0.3 2.3 0.7 1.3 0.4 1.9 0.4 323 7 321 305 7.6 0 7.7 7.7 07/16/2005 20:20:00 1.5 0.5 2.3 0.4 1.1 0.5 2.3 0.4 321 8 318 305 7.6 0 7.7 7.7 07/16/2005 20:30:00 1.9 0.3 2.6 1.1 1.7 0.4 2.3 0.7 316 7 316 305 7.7 0 7.9 7.7 07/16/2005 20:40:00 2.3 0.4 3.4 0.7 1.9 0.4 2.6 0.7 312 7 312 305 7.8 0 7.9 7.7 07/16/2005 20:50:00 2.7 0.4 3.4 1.5 2.4 0.4 3.4 1.5 311 10 311 305 7.9 0 7.9 7.7 07/16/2005 21:00:00 3 0.4 3.8 1.9 2.7 0.4 3.8 1.9 310 11 316 305 7.9 0 8.2 7.9 07/16/2005 21:10:00 3.3 0.3 3.8 2.6 2.9 0.3 3.4 2.3 310 9 354 305 7.9 0 7.9 7.7 07/16/2005 21:20:00 3 0.4 3.8 1.9 2.6 0.4 3.4 1.5 310 15 307 305 7.9 0 7.9 7.7 07/16/2005 21:30:00 2.9 0.4 3.8 1.9 2.6 0.3 3.4 1.9 309 13 312 305 7.9 0 7.9 7.7 07/16/2005 21:40:00 3.1 0.4 3.8 1.9 2.7 0.3 3.8 1.9 310 9 305 305 7.9 0 7.9 7.7 07/16/2005 21:50:00 2.6 0.3 3.4 1.9 2.3 0.4 3 1.5 310 11 303 305 7.9 0 7.9 7.7 07/16/2005 22:00:00 2.5 0.3 3.4 1.5 2.2 0.3 3 1.1 309 13 310 305 7.9 0 8.2 7.9 07/16/2005 22:10:00 2.2 0.4 3 1.1 1.9 0.5 3 0.7 310 8 309 305 7.9 0 8.2 7.7 07/16/2005 22:20:00 2.1 0.3 2.6 1.5 1.7 0.4 2.6 0.7 309 9 311 305 7.8 0 7.9 7.7 07/16/2005 22:30:00 2.1 0.3 2.6 1.1 1.7 0.4 2.6 0.7 310 11 305 305 7.9 0 7.9 7.7 07/16/2005 22:40:00 2.2 0.3 3 1.5 1.9 0.4 2.6 0.7 308 15 305 305 7.9 0 7.9 7.9 07/16/2005 22:50:00 1.9 0.4 2.6 1.1 1.3 0.5 2.3 0.4 310 11 306 305 7.9 0 7.9 7.9 07/16/2005 23:00:00 0.9 0.5 2.3 0.4 0.6 0.3 1.9 0.4 316 12 306 305 7.9 0 7.9 7.7 07/16/2005 23:10:00 0.4 0.3 1.9 0.4 0.4 0 0.4 0.4 302 19 280 305 8 0 8.2 7.9 07/16/2005 23:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 8 56 310 305 8 0 8.2 7.9 07/16/2005 23:30:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 319 9 316 305 8.1 0 8.2 7.9 07/16/2005 23:40:00 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 305 12 318 305 8 0 8.2 7.9 07/16/2005 23:50:00 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 307 13 303 305 8 0 8.2 7.9 07/17/2005 00:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 301 12 297 305 8 0 8.2 7.7 07/17/2005 00:10:00 0.6 0.3 1.9 0.4 0.4 0.2 1.1 0.4 306 10 302 305 8 0 8.2 7.9 07/17/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 313 10 305 305 8 0 8.2 7.9 07/17/2005 00:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 304 9 320 305 8 0 8.2 7.9 07/17/2005 00:40:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 322 23 325 305 8 0 8.2 7.9 07/17/2005 00:50:00 0.4 0.3 1.9 0.4 0.4 0.2 1.5 0.4 323 10 324 305 8 0 8.2 7.9 07/17/2005 01:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 335 18 332 305 8 0 8.2 7.9 07/17/2005 01:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 332 22 323 305 8 0 8.2 7.9 07/17/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 315 1 305 305 8 0 8.2 7.9 07/17/2005 01:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 311 8 305 305 8 0 8.2 7.9 07/17/2005 01:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 331 30 330 305 8 0 8.2 7.9 07/17/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 318 1 305 305 8 0 8.2 7.9 07/17/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 312 7 305 305 8 0 8.2 7.9 07/17/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 326 16 305 305 8 0 8.2 7.9 07/17/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 351 1 305 305 8 0 8.2 7.9 07/17/2005 02:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 350 1 349 305 8 0 8.2 7.9 07/17/2005 02:40:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 352 4 350 305 7.9 0 8.2 7.9 07/17/2005 02:50:00 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 10 4 12 305 8 0 8.2 7.9 07/17/2005 03:00:00 0.4 0.1 1.5 0.4 0.4 0.1 0.7 0.4 5 2 11 305 8 0 8.2 7.9 07/17/2005 03:10:00 1 0.6 3 0.4 0.8 0.4 2.3 0.4 17 11 0 305 8 0 8.2 7.9 07/17/2005 03:20:00 1.7 0.5 2.6 0.4 1.6 0.4 2.6 0.4 22 8 21 305 8 0 8.2 7.9 07/17/2005 03:30:00 1.7 0.3 2.3 1.1 1.7 0.3 2.6 1.1 18 6 29 305 7.9 0 8.2 7.9 07/17/2005 03:40:00 1.8 0.2 2.3 1.1 1.7 0.2 2.3 1.1 23 3 21 305 7.9 0 7.9 7.7 07/17/2005 03:50:00 2.3 0.4 3.4 1.1 2.3 0.3 3.4 1.5 20 9 21 305 7.8 0 7.9 7.7 07/17/2005 04:00:00 3.8 0.5 5.3 2.3 3.8 0.5 5.3 2.3 7 8 7 305 7.9 0 7.9 7.7 07/17/2005 04:10:00 4.2 0.3 4.9 3.4 4.3 0.3 4.9 3.8 7 3 4 305 7.6 0 7.9 7.4 07/17/2005 04:20:00 4 0.3 4.6 3.4 3.9 0.3 4.6 3.4 13 2 12 305 7.4 0 7.7 7.2 07/17/2005 04:30:00 3.6 0.3 4.2 3 3.5 0.3 4.2 3 13 2 13 305 7.3 0 7.4 7.2 07/17/2005 04:40:00 3 0.3 3.8 2.3 2.8 0.3 3.8 2.3 11 3 8 305 7.3 0 7.4 7.2 07/17/2005 04:50:00 2.8 0.3 3.4 2.3 2.5 0.3 3.4 1.9 21 7 22 305 7.2 0 7.4 7.2 07/17/2005 05:00:00 2.5 0.3 3.4 1.9 2.5 0.3 3 1.9 25 5 24 305 7.3 0 7.4 7.2 07/17/2005 05:10:00 2.2 0.3 3 1.1 2.2 0.3 2.6 1.5 29 8 29 305 7.3 0 7.4 7.4 07/17/2005 05:20:00 2.6 0.3 3.8 1.9 2.6 0.3 3.4 1.9 32 7 37 305 7.4 0 7.7 7.4 07/17/2005 05:30:00 3.1 0.3 3.8 2.3 3.2 0.3 3.8 2.3 36 6 29 305 7.5 0 7.7 7.4 07/17/2005 05:40:00 3.3 0.3 4.2 2.6 3.3 0.3 4.2 2.3 36 7 34 305 7.5 0 7.7 7.4 07/17/2005 05:50:00 3.3 0.3 3.8 2.6 3.3 0.3 3.8 2.6 38 6 32 305 7.5 0 7.7 7.4 07/17/2005 06:00:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 42 6 46 305 7.5 0 7.7 7.4 07/17/2005 06:10:00 3.5 0.4 4.2 2.6 3.5 0.4 4.2 2.6 36 5 41 305 7.5 0 7.7 7.4 07/17/2005 06:20:00 2.6 0.3 3.8 1.9 2.6 0.3 3.4 1.9 28 5 28 305 7.5 0 7.7 7.4 07/17/2005 06:30:00 2.6 0.2 3 1.9 2.6 0.2 3.4 2.3 30 4 28 305 7.5 0 7.7 7.4 07/17/2005 06:40:00 2.7 0.2 3.4 1.9 2.7 0.2 3.4 2.3 38 6 50 305 7.5 0 7.7 7.4 07/17/2005 06:50:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 2.3 36 6 40 305 7.5 0 7.7 7.4 07/17/2005 07:00:00 2.4 0.3 3 1.9 2.4 0.3 3 1.5 38 6 40 305 7.5 0 7.7 7.4 07/17/2005 07:10:00 2.1 0.3 3 1.1 2.2 0.3 2.6 1.5 37 6 41 305 7.6 0 7.7 7.7 07/17/2005 07:20:00 2 0.2 2.3 1.5 2 0.2 2.6 1.5 36 7 44 305 7.7 0 7.9 7.7 07/17/2005 07:30:00 1.4 0.4 2.3 0.4 1.6 0.4 2.3 0.4 37 10 35 305 7.7 0 7.9 7.7 07/17/2005 07:40:00 0.9 0.3 1.5 0.4 1 0.3 1.9 0.4 39 2 43 305 7.7 0 7.9 7.7 07/17/2005 07:50:00 0.8 0.3 1.5 0.4 1 0.2 1.5 0.4 36 3 32 305 7.8 0 7.9 7.7 07/17/2005 08:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 36 3 37 305 7.9 0 7.9 7.7 07/17/2005 08:10:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 34 2 33 305 7.9 0 7.9 7.7 07/17/2005 08:20:00 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 19 11 17 305 8 0 8.2 7.9 07/17/2005 08:30:00 1 0.3 1.5 0.4 1.1 0.2 1.5 0.4 19 6 14 305 8 0 8.2 7.9 07/17/2005 08:40:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 22 2 23 305 8 0 8.2 7.9 07/17/2005 08:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 13 7 305 305 8.1 0 8.2 7.9 07/17/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 351 2 305 305 8.2 0 8.2 8.2 07/17/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 26 305 305 8.2 0 8.4 8.2 07/17/2005 09:20:00 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 272 17 294 305 8.4 0 8.4 8.2 07/17/2005 09:30:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 309 15 329 305 8.4 0 8.4 8.2 07/17/2005 09:40:00 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 314 10 319 305 8.4 0 8.4 8.2 07/17/2005 09:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 328 2 305 305 8.4 0 8.4 8.2 07/17/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 11 12 305 305 8.4 0 8.7 8.2 07/17/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 2 305 305 8.6 0 8.9 8.4 07/17/2005 10:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 32 19 51 305 8.6 0 8.7 8.4 07/17/2005 10:30:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 31 10 24 305 8.5 0 8.7 8.4 07/17/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 28 2 305 305 8.6 0 8.7 8.4 07/17/2005 10:50:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 27 2 30 305 8.6 0 8.7 8.4 07/17/2005 11:00:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 42 13 24 305 8.5 0 8.7 8.4 07/17/2005 11:10:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 39 5 36 305 8.5 0 8.7 8.4 07/17/2005 11:20:00 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 17 5 39 305 8.5 0 8.7 8.4 07/17/2005 11:30:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 15 3 15 305 8.5 0 9.2 8.4 07/17/2005 11:40:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 22 10 28 305 8.4 0 8.9 8.2 07/17/2005 11:50:00 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 22 8 31 305 8.4 0 8.4 8.2 07/17/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9 1 305 305 8.6 0 9.2 8.4 07/17/2005 12:10:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 6 9 18 305 8.8 0 9.2 8.7 07/17/2005 12:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 35 6 14 305 8.9 0 9.5 8.9 07/17/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 22 305 305 9.3 0.1 9.7 9.2 07/17/2005 12:40:00 0.6 0.4 1.5 0.4 0.8 0.5 1.9 0.4 35 36 60 305 9.2 0 9.7 8.9 07/17/2005 12:50:00 0.9 0.4 1.9 0.4 1.1 0.4 2.3 0.4 47 17 64 305 8.9 0 9.2 8.7 07/17/2005 13:00:00 0.9 0.5 2.3 0.4 1.1 0.4 2.3 0.4 43 13 56 305 8.8 0.1 9.2 8.7 07/17/2005 13:10:00 1.2 0.4 2.3 0.4 1.4 0.3 2.3 0.7 44 14 31 305 8.8 0.1 9.2 8.7 07/17/2005 13:20:00 1.5 0.4 2.3 0.4 1.6 0.3 2.3 0.7 44 7 44 305 8.8 0.1 9.2 8.7 07/17/2005 13:30:00 2.1 0.3 2.6 1.5 2.1 0.3 2.6 1.5 44 6 44 305 8.8 0.1 9.2 8.7 07/17/2005 13:40:00 2.4 0.3 3 1.5 2.4 0.3 3.4 1.5 42 5 45 305 8.8 0.1 9.2 8.7 07/17/2005 13:50:00 2.5 0.3 3.8 1.5 2.5 0.3 3.4 1.9 40 7 39 305 8.8 0.1 9.2 8.7 07/17/2005 14:00:00 2.4 0.4 3.4 1.5 2.4 0.3 3.4 1.9 37 9 43 305 8.9 0.1 9.2 8.7 07/17/2005 14:10:00 2.2 0.4 3.4 1.1 2.3 0.4 3 1.1 31 9 35 305 8.9 0 9.2 8.9 07/17/2005 14:20:00 2.1 0.4 3 1.1 2.1 0.4 3 1.1 35 8 32 305 8.9 0 9.2 8.9 07/17/2005 14:30:00 2.3 0.4 3.8 1.1 2.4 0.4 3.4 1.5 45 9 38 305 9.1 0 9.2 8.9 07/17/2005 14:40:00 2.3 0.4 3.4 1.1 2.4 0.4 3.8 1.5 38 9 57 305 9.2 0 9.2 9.2 07/17/2005 14:50:00 2.3 0.4 3.4 1.1 2.4 0.4 3.4 1.5 37 10 45 305 9.2 0 9.5 9.2 07/17/2005 15:00:00 2.1 0.4 3 1.1 2.2 0.4 3.4 1.1 42 9 40 305 9.2 0 9.5 9.2 07/17/2005 15:10:00 1.8 0.4 3 0.7 1.9 0.4 3 1.1 46 9 35 305 9.2 0 9.2 9.2 07/17/2005 15:20:00 1.8 0.5 3 0.4 1.9 0.4 3 0.7 40 12 42 305 9.2 0 9.5 9.2 07/17/2005 15:30:00 1.9 0.4 3 1.1 1.9 0.3 3 1.1 46 13 53 305 9.3 0.1 9.5 9.2 07/17/2005 15:40:00 1.5 0.4 2.6 0.4 1.7 0.5 3 0.4 40 14 47 305 9.3 0 9.7 9.2 07/17/2005 15:50:00 1.7 0.5 2.6 0.4 1.7 0.5 3 0.4 44 15 22 305 9.7 0 10 9.5 07/17/2005 16:00:00 1.6 0.5 2.6 0.4 1.7 0.4 2.6 0.7 33 15 30 305 9.7 0 9.7 9.7 07/17/2005 16:10:00 1.7 0.5 3 0.4 1.8 0.4 2.6 0.4 25 11 35 305 9.9 0 10.2 9.7 07/17/2005 16:20:00 1.2 0.5 2.3 0.4 1.5 0.5 3 0.4 6 16 9 305 10.2 0 10.2 10 07/17/2005 16:30:00 1.8 0.5 3 0.7 1.8 0.5 3.4 0.7 351 16 334 305 10.4 0 10.5 10.2 07/17/2005 16:40:00 2 0.5 3 0.7 2 0.5 3 0.4 344 17 345 305 10.2 0 10.2 10 07/17/2005 16:50:00 2.2 0.5 3.8 0.7 2.1 0.4 3 1.1 300 26 265 305 9.9 0 10.2 9.7 07/17/2005 17:00:00 1.6 0.6 3.4 0.4 1.5 0.5 3.4 0.4 255 18 287 305 10.5 0.1 10.8 10.2 07/17/2005 17:10:00 2.2 0.5 3.8 0.7 2.2 0.5 3.8 0.7 194 17 188 305 10.6 0.2 11 10.2 07/17/2005 17:20:00 2 0.6 3.4 0.7 2 0.5 3.8 0.7 222 19 218 305 10.3 0 10.5 10.2 07/17/2005 17:30:00 1.5 0.6 2.6 0.4 1.7 0.5 3 0.4 238 15 220 305 10.3 0 10.5 10.2 07/17/2005 17:40:00 2.5 0.4 3.8 1.1 2.4 0.5 3.8 0.7 250 12 256 305 10.4 0 10.5 10.2 07/17/2005 17:50:00 2.5 0.5 3.4 1.1 2.5 0.5 3.8 1.1 251 13 243 305 10.5 0.1 10.8 10.2 07/17/2005 18:00:00 3.2 0.5 4.6 1.9 3.1 0.5 4.6 1.5 241 13 244 305 10.4 0 10.8 10.2 07/17/2005 18:10:00 3.4 0.4 4.6 2.3 3.4 0.4 4.2 2.3 227 9 229 305 10.4 0.1 10.8 10.2 07/17/2005 18:20:00 3.3 0.5 4.6 2.3 3.1 0.5 4.6 1.9 230 11 237 305 10.4 0 10.5 10.2 07/17/2005 18:30:00 3.6 0.6 4.9 2.3 3.4 0.6 4.9 2.3 250 9 251 305 10.2 0.1 10.5 10 07/17/2005 18:40:00 3.5 0.5 4.9 1.9 3.3 0.6 4.9 1.9 254 9 239 305 10.6 0.1 11 10.2 07/17/2005 18:50:00 3.8 0.4 4.9 2.6 3.7 0.5 4.6 2.3 252 8 256 305 10.7 0.1 11 10.5 07/17/2005 19:00:00 4 0.5 5.3 2.3 3.9 0.5 4.9 2.3 248 7 245 305 10.4 0.1 10.8 10.2 07/17/2005 19:10:00 4.4 0.5 5.3 2.6 4.2 0.5 5.3 3 249 8 249 305 10.5 0 10.8 10.2 07/17/2005 19:20:00 4.1 0.6 5.7 2.6 3.9 0.5 5.7 2.6 244 9 251 305 10.6 0.1 11 10.5 07/17/2005 19:30:00 3.8 0.5 5.3 2.6 3.7 0.5 4.9 2.6 243 9 238 305 10.9 0 11 10.8 07/17/2005 19:40:00 4.3 0.4 5.3 3 4.2 0.4 5.7 3 238 8 251 305 10.6 0 11 10.2 07/17/2005 19:50:00 4.4 0.6 6.1 2.6 4.3 0.5 5.7 3 240 9 251 305 10.4 0 10.8 10.2 07/17/2005 20:00:00 4.5 0.5 6.1 3 4.3 0.5 5.7 2.6 236 9 242 305 10.4 0 10.5 10.2 07/17/2005 20:10:00 4.5 0.7 6.5 3 4.4 0.7 6.1 3 241 10 252 305 10.4 0 10.8 10.2 07/17/2005 20:20:00 5 0.7 6.5 3 4.9 0.7 6.5 2.6 244 9 259 305 10.2 0 10.5 10 07/17/2005 20:30:00 4.8 0.6 6.5 3.4 4.6 0.6 6.1 3 239 8 237 305 10.4 0 10.5 10.2 07/17/2005 20:40:00 5.1 0.7 6.8 3.4 4.9 0.7 6.5 3 239 8 229 305 10.2 0 10.2 10 07/17/2005 20:50:00 4.9 0.5 6.5 3.8 4.7 0.6 6.1 3 232 8 238 305 10.1 0 10.2 10 07/17/2005 21:00:00 4.5 0.6 6.1 3 4.4 0.6 6.1 3 224 7 230 305 10.2 0 10.2 10 07/17/2005 21:10:00 4.4 0.5 5.7 3 4.2 0.5 5.7 3 222 7 228 305 10.2 0 10.2 10 07/17/2005 21:20:00 4.7 0.5 6.1 3 4.5 0.5 5.7 3 219 7 234 305 10 0.1 10.2 9.7 07/17/2005 21:30:00 4.1 0.5 5.7 2.6 3.9 0.5 5.3 2.6 217 7 221 305 9.8 0 10 9.7 07/17/2005 21:40:00 4.4 0.5 5.7 3 4.3 0.4 5.7 3 221 6 213 305 9.8 0 10 9.7 07/17/2005 21:50:00 4.5 0.5 5.7 3.4 4.3 0.5 5.3 3 221 6 224 305 9.7 0 9.7 9.7 07/17/2005 22:00:00 4 0.5 5.3 2.6 3.8 0.5 4.9 2.3 218 8 218 305 9.7 0 10 9.7 07/17/2005 22:10:00 3.9 0.5 4.9 2.6 3.9 0.4 4.9 2.6 216 7 223 305 9.9 0 10 9.7 07/17/2005 22:20:00 3.9 0.5 4.9 2.6 3.9 0.5 4.9 2.6 204 7 210 305 9.7 0 10 9.5 07/17/2005 22:30:00 3.7 0.5 5.3 2.3 3.8 0.5 5.7 2.3 205 9 198 305 9.4 0 9.7 9.5 07/17/2005 22:40:00 3.9 0.5 5.3 2.6 4 0.5 5.3 3 204 9 219 305 9.3 0 9.5 9.2 07/17/2005 22:50:00 4.2 0.6 5.7 2.6 4.3 0.6 6.1 2.6 208 12 208 305 9.1 0 9.2 9.2 07/17/2005 23:00:00 3.8 0.6 5.3 1.9 3.8 0.5 4.9 2.6 205 12 225 305 9.1 0 9.2 9.2 07/17/2005 23:10:00 3.5 0.5 4.9 2.3 3.6 0.5 4.9 2.3 204 12 218 305 9.2 0 9.5 9.2 07/17/2005 23:20:00 3.4 0.7 5.7 1.5 3.5 0.6 5.3 2.3 203 14 221 305 9.2 0 9.2 9.2 07/17/2005 23:30:00 3.3 0.6 4.6 1.5 3.3 0.6 4.6 1.5 209 11 214 305 9.1 0 9.2 9.2 07/17/2005 23:40:00 3.3 0.5 4.9 2.3 3.3 0.4 4.2 2.3 209 10 208 305 9.1 0 9.2 9.2 07/17/2005 23:50:00 3.3 0.5 4.6 1.9 3.5 0.5 4.9 2.3 195 12 217 305 9.1 0 9.2 9.2 07/18/2005 00:00:00 2.8 0.8 4.6 1.1 2.9 0.8 4.2 1.1 210 18 203 305 9.1 0 9.7 9.2 07/18/2005 00:10:00 2.1 0.5 3.4 0.4 2.2 0.5 3.4 0.7 217 15 221 305 9.2 0 9.2 9.2 07/18/2005 00:20:00 2.4 0.5 3.4 1.5 2.4 0.5 3.4 1.1 209 15 206 305 9.2 0 9.2 9.2 07/18/2005 00:30:00 3 0.5 4.6 1.5 3 0.5 4.6 1.9 210 21 254 305 9.2 0 9.2 9.2 07/18/2005 00:40:00 2.6 0.6 4.9 1.1 2.5 0.5 4.6 0.7 219 18 245 305 9.2 0 9.5 9.2 07/18/2005 00:50:00 2 0.5 3 0.7 2.3 0.4 3.8 1.5 195 11 200 305 9.2 0 9.2 9.2 07/18/2005 01:00:00 1.9 0.5 3 0.4 2.2 0.4 3 1.5 203 15 230 305 9.2 0 9.2 9.2 07/18/2005 01:10:00 0.9 0.6 2.6 0.4 1 0.7 2.6 0.4 201 15 179 305 9.2 0 9.2 9.2 07/18/2005 01:20:00 0.6 0.4 1.9 0.4 0.8 0.5 1.9 0.4 214 18 208 305 9.2 0 9.2 9.2 07/18/2005 01:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 206 24 214 305 9.2 0 9.2 9.2 07/18/2005 01:40:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 193 5 204 305 9.2 0 9.5 9.2 07/18/2005 01:50:00 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 206 3 204 305 9.2 0 9.5 9.2 07/18/2005 02:00:00 1.7 0.6 2.6 0.4 1.9 0.5 3 0.7 209 4 210 305 9.2 0 9.2 9.2 07/18/2005 02:10:00 1.9 0.4 3 1.1 2.3 0.3 3 1.5 209 5 205 305 9.1 0 9.2 9.2 07/18/2005 02:20:00 2.7 0.2 3.4 2.3 2.9 0.3 3.4 2.3 206 4 206 305 9.1 0 9.2 8.9 07/18/2005 02:30:00 3 0.4 3.8 1.9 3.1 0.3 3.8 2.3 206 4 206 305 9.1 0 9.2 8.9 07/18/2005 02:40:00 1.3 1 3 0.4 1.8 0.8 3 0.4 198 16 205 305 9.1 0 9.2 8.9 07/18/2005 02:50:00 0.8 0.5 2.3 0.4 1.4 0.6 2.6 0.4 186 35 190 305 9.2 0 9.5 9.2 07/18/2005 03:00:00 0.4 0.2 1.5 0.4 0.8 0.4 1.9 0.4 157 38 189 305 9.3 0 9.5 9.2 07/18/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 91 35 305 305 9.5 0 9.7 9.5 07/18/2005 03:20:00 0.4 0.2 1.1 0.4 0.7 0.3 1.5 0.4 142 64 204 305 9.5 0 9.7 9.5 07/18/2005 03:30:00 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 193 35 193 305 9.3 0 9.5 9.2 07/18/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 111 33 305 305 8.9 0 9.2 8.9 07/18/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 104 22 305 305 8.8 0 8.9 8.7 07/18/2005 04:00:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 142 0 305 305 8.4 0.1 8.7 8.2 07/18/2005 04:10:00 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 130 9 144 305 8.2 0 8.4 8.2 07/18/2005 04:20:00 0.4 0.2 1.5 0.4 0.5 0.5 2.3 0.4 176 56 194 305 8.8 0.1 9.2 8.2 07/18/2005 04:30:00 0.4 0.1 1.1 0.4 0.5 0.4 1.9 0.4 149 18 160 305 9.3 0 9.5 9.2 07/18/2005 04:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.9 0.4 176 8 138 305 8.9 0.1 9.2 8.7 07/18/2005 04:50:00 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 166 19 143 305 8.7 0.1 9.2 8.4 07/18/2005 05:00:00 1.8 0.8 3 0.4 2.1 0.8 3.4 0.4 211 12 198 305 8.6 0.3 9.2 8.2 07/18/2005 05:10:00 2 0.5 3 0.7 2.6 0.3 3.4 1.9 191 5 200 305 8 0 8.4 7.9 07/18/2005 05:20:00 1.3 0.5 2.3 0.4 2.1 0.4 3 1.5 191 3 193 305 8.1 0.1 8.7 7.9 07/18/2005 05:30:00 0.9 0.5 1.9 0.4 1.7 0.3 2.3 1.1 191 6 197 305 8.2 0.1 8.7 8.2 07/18/2005 05:40:00 1.9 0.3 2.6 1.1 2.3 0.2 2.6 1.9 196 5 196 305 8.4 0 8.9 8.2 07/18/2005 05:50:00 1.2 0.8 2.6 0.4 1.7 0.5 2.6 0.4 193 9 202 305 8.7 0 9.2 8.4 07/18/2005 06:00:00 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 183 15 208 305 8.8 0.2 9.5 8.4 07/18/2005 06:10:00 0.6 0.3 1.5 0.4 1.3 0.4 1.9 0.4 189 11 213 305 8.9 0.2 9.5 8.7 07/18/2005 06:20:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 179 19 197 305 8.7 0.2 9.2 8.4 07/18/2005 06:30:00 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 202 3 204 305 8.8 0.1 9.2 8.4 07/18/2005 06:40:00 1.8 0.3 2.3 1.1 1.4 0.5 2.3 0.4 189 4 192 305 8.8 0.1 9.5 8.4 07/18/2005 06:50:00 2.3 0.5 3 1.5 2.3 0.7 3.4 1.1 191 4 196 305 9.1 0 9.7 8.9 07/18/2005 07:00:00 3.2 0.3 3.8 2.3 3.6 0.2 4.2 3 193 5 190 305 9.5 0.1 10.2 9.2 07/18/2005 07:10:00 4.1 0.4 4.9 3 4.2 0.4 4.9 3 197 4 201 305 10.2 0 10.5 9.7 07/18/2005 07:20:00 4.4 0.3 5.3 3 4.5 0.4 5.3 3 192 5 194 305 9.9 0 10.2 10 07/18/2005 07:30:00 5.5 0.6 6.5 3.4 5.6 0.6 6.5 3.8 201 4 202 305 9.2 0.5 10 8.4 07/18/2005 07:40:00 5.3 0.4 6.1 4.2 5.2 0.5 6.1 3.8 205 5 205 305 8.2 0.1 8.4 8.2 07/18/2005 07:50:00 5 0.5 5.7 3 4.9 0.6 5.7 3 204 4 202 305 8.2 0 8.4 8.2 07/18/2005 08:00:00 5.3 0.5 6.5 4.6 5.3 0.5 6.8 4.2 203 3 206 305 8 0 8.2 7.9 07/18/2005 08:10:00 6 0.4 7.2 4.9 6 0.4 7.2 4.9 204 3 204 305 7.7 0.1 8.2 7.4 07/18/2005 08:20:00 6.2 0.5 7.2 4.2 6.1 0.5 7.2 4.2 207 5 208 305 7.2 0.1 7.7 7.2 07/18/2005 08:30:00 6.1 0.4 7.2 4.9 5.9 0.5 6.8 4.6 199 6 198 305 7.2 0.1 7.4 7.2 07/18/2005 08:40:00 6.1 0.6 7.2 4.6 5.9 0.7 7.2 4.2 198 4 203 305 7.3 0 7.4 7.2 07/18/2005 08:50:00 5.9 0.4 6.8 4.9 5.8 0.4 6.8 4.6 200 5 202 305 7.5 0 7.7 7.4 07/18/2005 09:00:00 5.9 0.4 7.2 4.9 6 0.4 6.8 4.9 202 7 213 305 7.9 0 8.2 7.7 07/18/2005 09:10:00 5.5 0.5 6.8 4.2 5.4 0.5 6.5 3.8 198 6 202 305 8.2 0 8.4 8.2 07/18/2005 09:20:00 5.4 0.4 6.5 4.2 5.4 0.4 6.5 4.2 200 5 203 305 8.4 0 8.7 8.2 07/18/2005 09:30:00 5.2 0.3 6.1 4.6 5.1 0.3 6.1 4.2 203 4 200 305 8.8 0.1 9.2 8.4 07/18/2005 09:40:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 3.8 201 4 198 305 9.1 0 9.2 8.9 07/18/2005 09:50:00 4.8 0.5 6.1 3.8 4.7 0.4 5.7 3.8 202 5 198 305 9.3 0 9.7 9.2 07/18/2005 10:00:00 5.2 0.4 6.1 4.2 5.1 0.4 6.1 3.8 199 3 205 305 9.3 0.1 10 9.2 07/18/2005 10:10:00 5.3 0.4 6.5 4.2 5.3 0.5 6.1 3.4 202 4 213 305 9.1 0 9.7 8.9 07/18/2005 10:20:00 5.2 0.4 6.1 3.4 5.2 0.5 6.1 3.8 200 4 197 305 9.3 0 9.5 9.2 07/18/2005 10:30:00 5.5 0.4 6.5 4.6 5.5 0.5 6.8 4.2 206 5 205 305 9.5 0 9.7 9.5 07/18/2005 10:40:00 5.8 0.3 6.5 4.6 5.8 0.4 6.8 4.6 206 3 204 305 9.5 0 9.7 9.2 07/18/2005 10:50:00 5.7 0.3 6.5 4.9 5.7 0.4 6.5 4.2 204 3 201 305 9.7 0 10 9.5 07/18/2005 11:00:00 5.5 0.4 6.5 4.6 5.5 0.5 6.5 4.2 204 3 201 305 9.8 0 10 9.7 07/18/2005 11:10:00 5.7 0.5 6.5 4.6 5.6 0.5 6.8 4.6 203 4 205 305 9.9 0 10 9.7 07/18/2005 11:20:00 5.8 0.6 6.8 3.8 5.7 0.6 6.8 3.8 203 5 201 305 9.9 0 10.2 9.7 07/18/2005 11:30:00 5.7 0.4 6.8 4.6 5.6 0.5 6.8 4.2 206 5 210 305 10.1 0 10.2 10 07/18/2005 11:40:00 5.5 0.6 7.2 3.8 5.5 0.5 6.8 3.8 209 6 214 305 10 0 10.2 9.7 07/18/2005 11:50:00 5.3 0.6 6.8 3.8 5.2 0.6 6.8 3.4 202 7 201 305 10.2 0 10.5 10 07/18/2005 12:00:00 4.8 0.5 6.1 3 4.7 0.5 6.1 3.4 202 8 206 305 10.3 0 10.5 10.2 07/18/2005 12:10:00 5 0.5 6.5 3.8 4.9 0.6 6.5 3 203 7 211 305 10.3 0 10.5 10.2 07/18/2005 12:20:00 5.3 0.4 6.5 3.8 5.2 0.5 6.1 3.8 201 6 197 305 9.8 0.2 10.2 9.5 07/18/2005 12:30:00 5.4 0.5 6.5 4.2 5.4 0.5 6.5 3.8 204 6 215 305 9.1 0.2 9.7 8.7 07/18/2005 12:40:00 5.5 0.4 6.5 4.2 5.3 0.5 6.1 3.8 216 6 221 305 8.6 0 8.9 8.2 07/18/2005 12:50:00 5.6 0.5 6.5 4.2 5.4 0.5 6.5 3.8 219 5 213 305 8.2 0 8.4 8.2 07/18/2005 13:00:00 5 0.6 6.1 3.4 4.8 0.6 6.1 3 219 7 219 305 8.2 0 8.4 8.2 07/18/2005 13:10:00 5.1 0.5 6.1 3.8 5 0.5 6.1 3.8 218 6 215 305 8 0 8.2 7.9 07/18/2005 13:20:00 5.1 0.6 6.5 3.4 4.9 0.5 6.5 3.4 227 7 231 305 8.1 0 8.4 7.9 07/18/2005 13:30:00 5.4 0.6 6.8 3.8 5.3 0.6 6.8 3.8 220 7 224 305 8.1 0 8.2 7.9 07/18/2005 13:40:00 5.8 0.4 6.8 4.6 5.7 0.5 6.8 3.8 223 6 221 305 8 0 8.2 7.7 07/18/2005 13:50:00 5.6 0.5 6.8 4.2 5.5 0.5 7.2 3.8 218 6 214 305 8 0 8.2 7.7 07/18/2005 14:00:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 3.8 224 5 239 305 7.9 0.1 8.2 7.7 07/18/2005 14:10:00 5.2 0.5 6.8 3.8 5.1 0.6 6.8 3.4 215 6 222 305 8 0.1 8.2 7.7 07/18/2005 14:20:00 5.5 0.4 6.5 4.2 5.4 0.5 6.5 4.2 225 8 229 305 7.8 0.2 8.2 7.4 07/18/2005 14:30:00 5.7 0.5 6.8 4.2 5.5 0.5 6.8 3.8 223 8 228 305 7.9 0 8.2 7.7 07/18/2005 14:40:00 5.7 0.5 7.2 4.2 5.6 0.5 6.8 4.2 219 8 229 305 8 0 8.2 7.7 07/18/2005 14:50:00 5.9 0.6 7.6 4.2 5.7 0.6 7.2 4.2 235 6 230 305 7.8 0.2 8.2 7.4 07/18/2005 15:00:00 6.1 0.6 7.2 4.6 5.8 0.5 7.2 4.6 238 6 247 305 7.6 0 7.9 7.4 07/18/2005 15:10:00 5.6 0.7 7.2 3.8 5.3 0.6 6.8 3.8 235 6 243 305 7.6 0 7.9 7.4 07/18/2005 15:20:00 5.8 0.7 7.2 4.2 5.6 0.7 7.2 3.4 231 9 231 305 7.9 0 7.9 7.7 07/18/2005 15:30:00 6.2 0.7 8 4.6 5.9 0.7 7.6 4.2 226 6 227 305 8.2 0 8.4 7.7 07/18/2005 15:40:00 6.1 0.6 7.2 4.2 5.8 0.6 6.8 4.2 240 6 242 305 8 0 8.2 7.9 07/18/2005 15:50:00 5.7 0.8 7.2 4.2 5.5 0.8 7.2 3.8 233 9 236 305 8 0.1 8.4 7.7 07/18/2005 16:00:00 5.9 0.6 7.2 4.6 5.6 0.6 7.2 3.4 216 7 218 305 8.3 0 8.7 8.2 07/18/2005 16:10:00 5.8 0.5 7.6 4.2 5.6 0.6 7.2 3.8 229 7 231 305 8.2 0.1 8.4 7.7 07/18/2005 16:20:00 5.4 0.6 6.8 3.8 5.1 0.6 6.1 3.8 230 8 231 305 8.1 0 8.2 7.9 07/18/2005 16:30:00 5.6 0.6 7.2 4.6 5.3 0.6 6.8 3.8 222 7 234 305 8.2 0 8.4 8.2 07/18/2005 16:40:00 6.4 0.6 8 4.9 6.2 0.6 7.6 4.6 225 8 233 305 7.9 0 8.2 7.7 07/18/2005 16:50:00 6.1 0.7 7.6 4.2 5.9 0.6 7.2 4.2 228 6 234 305 7.8 0.1 8.2 7.7 07/18/2005 17:00:00 6.3 0.8 7.6 4.6 6.1 0.8 7.6 4.2 227 6 234 305 7.9 0 8.4 7.7 07/18/2005 17:10:00 6.1 0.6 7.6 4.2 5.7 0.6 7.2 4.2 227 6 224 305 8.1 0 8.7 7.9 07/18/2005 17:20:00 6.7 0.7 8.4 4.9 6.3 0.7 8.4 4.6 225 5 218 305 8.4 0.1 8.9 8.2 07/18/2005 17:30:00 7.1 0.6 8.4 5.3 6.8 0.6 8 4.9 224 7 218 305 8.4 0 8.9 8.2 07/18/2005 17:40:00 7.1 0.6 8.8 5.7 6.8 0.6 8.4 4.9 232 4 237 305 8.2 0.1 8.9 8.2 07/18/2005 17:50:00 7 0.8 8.8 4.9 6.6 0.8 8.4 4.9 223 6 221 305 8.3 0.2 8.9 7.9 07/18/2005 18:00:00 7 0.5 8.4 5.7 6.4 0.6 8.4 4.2 232 6 227 305 8.3 0.1 8.7 8.2 07/18/2005 18:10:00 7.4 0.7 9.1 5.3 6.8 0.8 9.1 3.8 236 6 238 305 8.1 0 8.4 8.2 07/18/2005 18:20:00 7.1 0.6 8.4 5.3 6.4 0.7 8 4.6 240 6 239 305 8.1 0 8.4 7.9 07/18/2005 18:30:00 6.8 0.8 8.4 4.6 6.3 0.9 8 4.2 233 7 230 305 8.1 0 8.2 7.9 07/18/2005 18:40:00 7.9 0.6 9.5 5.3 7.4 0.7 9.1 5.3 228 5 229 305 8.2 0 8.2 7.9 07/18/2005 18:50:00 7.6 0.7 9.1 4.9 7 0.8 8.4 4.9 230 6 224 305 8.1 0 8.4 7.9 07/18/2005 19:00:00 7.1 0.6 8.4 4.9 6.7 0.7 8 4.6 234 5 231 305 8.2 0.1 8.7 7.9 07/18/2005 19:10:00 6.5 0.7 8.4 4.6 6.1 0.7 7.6 4.2 236 5 233 305 8.2 0.1 8.9 8.2 07/18/2005 19:20:00 7.6 0.8 9.5 4.9 7.1 1 9.1 4.2 230 6 231 305 8.1 0 8.7 7.9 07/18/2005 19:30:00 7.1 0.7 9.1 4.9 6.5 0.8 8.4 4.6 232 5 234 305 8 0 8.4 7.9 07/18/2005 19:40:00 7.8 0.7 9.5 5.3 7.2 0.8 9.1 4.9 233 6 236 305 8.1 0 8.4 7.9 07/18/2005 19:50:00 7.6 0.7 9.1 5.7 7.2 0.8 8.8 5.3 231 7 239 305 8.1 0 8.4 7.9 07/18/2005 20:00:00 7.9 0.7 9.5 6.1 7.2 0.8 9.1 5.3 238 6 238 305 8.1 0 8.4 8.2 07/18/2005 20:10:00 7.9 0.6 9.5 6.1 7.4 0.7 9.1 5.7 235 5 234 305 8.2 0 8.7 8.2 07/18/2005 20:20:00 8 0.6 9.5 5.7 7.6 0.6 9.1 5.7 233 5 233 305 8.2 0.1 8.7 8.2 07/18/2005 20:30:00 7.5 0.8 9.5 5.3 7 0.9 9.1 4.9 234 6 230 305 8.2 0.1 8.7 8.2 07/18/2005 20:40:00 8 0.7 9.1 5.7 7.1 0.8 8.8 4.6 240 5 241 305 8.2 0.1 8.9 8.2 07/18/2005 20:50:00 8 0.7 9.5 5.7 7.2 0.8 9.1 5.3 237 6 237 305 8.3 0.1 8.9 8.2 07/18/2005 21:00:00 7.5 0.7 9.1 5.7 6.8 0.8 9.1 4.6 238 6 246 305 8.3 0.1 8.9 8.2 07/18/2005 21:10:00 7.1 0.9 9.5 4.6 6.4 1 8.8 4.2 239 7 242 305 8.3 0.1 8.9 8.2 07/18/2005 21:20:00 7.8 0.8 9.9 5.7 7.2 0.8 9.5 5.3 237 5 240 305 8.2 0.1 8.9 8.2 07/18/2005 21:30:00 7.6 0.8 9.9 5.7 6.8 1 9.5 4.6 241 6 238 305 8.3 0 8.9 8.2 07/18/2005 21:40:00 7.6 0.8 9.1 5.3 6.8 0.8 8.8 4.9 240 6 244 305 8.2 0 8.4 8.2 07/18/2005 21:50:00 7.6 0.8 9.5 5.7 6.7 0.8 8.4 4.9 239 5 234 305 8.2 0 8.2 8.2 07/18/2005 22:00:00 8.1 0.7 9.9 6.5 7.3 0.7 9.1 5.7 243 6 241 305 8.2 0 8.2 8.2 07/18/2005 22:10:00 6.7 0.9 9.1 4.2 5.8 1 8.4 3.4 248 7 259 305 8.1 0 8.2 7.9 07/18/2005 22:20:00 6.9 0.8 8.8 4.6 6.1 1 8.4 4.2 246 7 249 305 8.1 0 8.2 8.2 07/18/2005 22:30:00 6.8 0.8 8.4 4.2 6.1 1 8.4 3 245 9 242 305 8.1 0 8.2 8.2 07/18/2005 22:40:00 6.4 1 8.8 3.8 5.5 1.1 8 2.6 253 7 245 305 8.1 0 8.2 7.9 07/18/2005 22:50:00 6.9 0.7 8.4 4.6 6 0.9 7.6 3.8 246 6 249 305 8.1 0 8.2 7.9 07/18/2005 23:00:00 6.4 0.6 7.6 4.9 5.7 0.8 7.2 3.8 245 6 249 305 8 0 8.2 7.9 07/18/2005 23:10:00 6.2 0.8 7.6 4.2 5.3 0.9 7.6 3.4 240 6 240 305 8 0 8.2 7.9 07/18/2005 23:20:00 6.9 0.9 8.4 4.6 6.1 0.9 8 3.8 241 5 247 305 8 0 8.2 7.9 07/18/2005 23:30:00 7.6 0.7 9.5 5.7 6.7 0.9 8.8 4.2 252 6 254 305 7.8 0 7.9 7.7 07/18/2005 23:40:00 7.3 0.7 9.1 5.3 6.4 1 8.8 3.8 246 7 239 305 7.7 0 8.2 7.7 07/18/2005 23:50:00 5.9 0.8 7.2 3.4 5.1 0.9 6.8 3 248 7 242 305 7.8 0 7.9 7.7 07/19/2005 00:00:00 6.7 0.8 8.4 4.9 6.1 0.8 8.4 4.2 240 6 241 305 7.8 0 8.2 7.7 07/19/2005 00:10:00 6.2 0.7 8.4 4.6 5.7 0.7 7.6 4.2 243 6 241 305 7.8 0 7.9 7.7 07/19/2005 00:20:00 6.7 0.8 8.8 4.9 6.2 0.8 8.4 4.2 240 6 236 305 7.9 0 7.9 7.7 07/19/2005 00:30:00 7.4 0.7 8.8 5.3 6.7 0.8 8.4 4.6 239 5 246 305 7.7 0 8.2 7.7 07/19/2005 00:40:00 7 0.7 8.8 5.3 6.5 0.8 8.4 4.6 240 6 234 305 7.6 0 7.7 7.7 07/19/2005 00:50:00 7.4 0.7 9.1 5.7 6.6 0.8 8.4 4.2 241 6 242 305 7.6 0 7.7 7.4 07/19/2005 01:00:00 6.9 1 8.8 3.8 6.3 1 8.8 3.8 244 6 239 305 7.5 0 7.7 7.4 07/19/2005 01:10:00 7 0.7 8.4 4.6 6.1 0.9 8 3.4 243 6 237 305 7.5 0 7.7 7.4 07/19/2005 01:20:00 7 0.8 9.1 4.2 6 0.9 8.4 3.8 248 6 248 305 7.5 0 7.7 7.4 07/19/2005 01:30:00 6.8 0.9 8.8 4.6 6.1 1 8.4 3.8 249 5 246 305 7.6 0 7.7 7.7 07/19/2005 01:40:00 6.3 0.7 8 4.6 5.5 0.8 7.2 3.4 247 7 247 305 7.6 0 7.7 7.7 07/19/2005 01:50:00 7.1 0.8 8.8 4.6 6.2 0.9 8 3.4 239 5 235 305 7.6 0 7.7 7.7 07/19/2005 02:00:00 7.4 0.7 8.8 5.3 6.4 0.8 8 4.2 247 7 248 305 7.6 0 7.9 7.7 07/19/2005 02:10:00 7.2 0.7 8.8 4.9 6.2 0.9 8 3.8 241 6 238 305 7.7 0 7.9 7.7 07/19/2005 02:20:00 7.3 1 9.5 5.3 6.4 1.1 8.8 4.2 246 7 242 305 7.6 0 7.7 7.4 07/19/2005 02:30:00 7.2 0.6 8.8 5.7 6.4 0.8 8.4 4.2 245 6 246 305 7.6 0 7.7 7.7 07/19/2005 02:40:00 7.7 0.7 9.9 5.3 6.8 0.9 8.8 4.2 245 5 246 305 7.5 0 7.7 7.4 07/19/2005 02:50:00 7.8 0.6 9.5 5.7 6.9 0.7 8.4 4.6 242 5 251 305 7.6 0 7.7 7.7 07/19/2005 03:00:00 8.2 0.6 9.5 6.5 7.2 0.8 8.8 4.9 243 5 246 305 7.6 0 7.7 7.7 07/19/2005 03:10:00 7.2 0.7 8.8 4.6 6.4 0.7 8 4.6 238 5 238 305 7.6 0 7.7 7.4 07/19/2005 03:20:00 6.4 0.7 8 4.6 5.6 0.8 7.6 3.8 238 5 236 305 7.7 0 7.7 7.7 07/19/2005 03:30:00 7.5 0.6 8.8 5.7 6.8 0.7 8.4 4.9 232 5 230 305 7.7 0 7.9 7.7 07/19/2005 03:40:00 7.3 0.6 8.8 5.3 6.5 0.6 8 4.6 234 4 236 305 7.6 0 7.7 7.7 07/19/2005 03:50:00 7.6 0.6 8.8 6.1 6.8 0.7 8.8 4.9 233 5 239 305 7.6 0 7.7 7.7 07/19/2005 04:00:00 7.2 0.7 8.8 4.9 6.5 0.8 8.4 4.6 239 6 242 305 7.7 0 7.7 7.7 07/19/2005 04:10:00 6.2 0.6 7.6 4.2 5.4 0.7 7.2 3.4 247 6 256 305 7.6 0 7.7 7.4 07/19/2005 04:20:00 7.1 0.6 8.8 5.3 6.3 0.8 8.8 4.2 244 5 243 305 7.5 0 7.7 7.4 07/19/2005 04:30:00 6.7 0.6 8 4.9 5.9 0.8 8 3.8 245 6 246 305 7.5 0 7.7 7.4 07/19/2005 04:40:00 7.8 0.8 9.1 5.7 6.8 1 9.1 3.8 247 5 251 305 7.5 0 7.7 7.4 07/19/2005 04:50:00 7.3 0.8 8.8 5.3 6.3 1 8.8 4.2 254 6 248 305 7.5 0 7.7 7.4 07/19/2005 05:00:00 7.2 0.7 9.1 4.9 6.3 1 8.4 3.8 249 7 253 305 7.5 0 7.7 7.4 07/19/2005 05:10:00 7 0.9 9.5 5.3 6.2 0.9 8.8 3.8 247 6 250 305 7.5 0 7.7 7.4 07/19/2005 05:20:00 7.7 0.9 9.5 5.3 6.8 1.1 9.5 3 250 6 256 305 7.3 0 7.7 7.2 07/19/2005 05:30:00 7.8 0.8 9.9 4.9 7 0.9 9.5 4.6 245 6 242 305 7.3 0 7.4 7.2 07/19/2005 05:40:00 8.2 0.8 10.3 6.1 7.4 1 9.5 4.9 244 6 236 305 7.3 0 7.4 7.2 07/19/2005 05:50:00 7.6 0.8 9.5 5.7 6.7 0.8 8.4 4.6 238 5 238 305 7.3 0 7.4 7.2 07/19/2005 06:00:00 8 0.9 9.9 5.3 7.1 1 9.1 4.9 243 6 248 305 7.3 0 7.4 7.2 07/19/2005 06:10:00 7.6 0.9 9.1 5.3 6.8 1.1 9.1 3.8 246 6 246 305 7.2 0 7.4 7.2 07/19/2005 06:20:00 7.3 0.7 9.1 5.3 6.5 0.8 8.4 4.6 245 5 253 305 7.2 0 7.4 7.2 07/19/2005 06:30:00 7.2 0.8 8.8 4.9 6.2 1 8.8 3.4 252 7 256 305 7.2 0 7.4 7.2 07/19/2005 06:40:00 7.8 0.7 9.1 5.3 6.8 1 8.8 3.8 253 5 257 305 7.3 0 7.4 7.2 07/19/2005 06:50:00 7.3 0.8 9.1 5.3 6.5 1 8.4 4.2 248 6 246 305 7.3 0 7.4 7.2 07/19/2005 07:00:00 7.3 0.8 9.5 4.9 6.6 1 8.8 3.8 247 6 243 305 7.3 0 7.4 7.2 07/19/2005 07:10:00 6.8 0.8 8.8 4.9 5.9 0.9 8 3.8 244 7 241 305 7.4 0 7.7 7.4 07/19/2005 07:20:00 6.9 0.8 8.8 4.9 6.3 0.9 8 3.8 248 7 246 305 7.5 0 7.7 7.4 07/19/2005 07:30:00 7.3 0.6 8.8 5.3 6.5 0.8 8.4 3.8 247 6 251 305 7.5 0 7.7 7.4 07/19/2005 07:40:00 6.9 0.6 8.4 4.6 5.6 0.8 7.6 3.4 256 8 252 305 7.3 0 7.4 7.4 07/19/2005 07:50:00 6.2 1 8 3.4 5.6 1 7.6 3 247 7 248 305 7.5 0 7.7 7.4 07/19/2005 08:00:00 6.7 0.7 8.4 4.9 5.9 0.8 8 4.2 243 6 243 305 7.5 0 7.9 7.4 07/19/2005 08:10:00 6.7 0.8 8 4.6 5.9 0.9 8 4.2 240 6 242 305 7.5 0 7.7 7.4 07/19/2005 08:20:00 7.1 0.8 8.8 4.6 6.4 0.9 8.4 3.4 245 6 249 305 7.4 0 7.7 7.2 07/19/2005 08:30:00 6.7 0.7 8.4 4.9 5.9 0.8 8 4.2 244 7 246 305 7.3 0 7.4 7.2 07/19/2005 08:40:00 6.9 0.6 8.4 5.3 6.4 0.7 8 4.6 247 6 248 305 7.3 0 7.7 7.2 07/19/2005 08:50:00 7.2 0.7 8.8 5.3 6.5 0.8 8 3.8 248 5 250 305 7.4 0 7.7 7.2 07/19/2005 09:00:00 6.7 0.7 8.4 4.6 5.9 0.9 8.4 3.4 245 7 248 305 7.4 0 7.7 7.4 07/19/2005 09:10:00 6.3 0.7 8 4.6 5.6 0.9 7.6 3 248 9 241 305 7.5 0 7.7 7.4 07/19/2005 09:20:00 4.9 0.6 6.5 3 4 0.6 5.7 2.3 268 9 268 305 7.5 0 7.7 7.4 07/19/2005 09:30:00 5.4 1 7.6 3 4.6 1 7.2 2.3 261 10 256 305 7.6 0 7.7 7.4 07/19/2005 09:40:00 5.7 0.7 7.6 3.8 4.8 0.8 6.8 3 254 8 244 305 7.5 0 7.7 7.4 07/19/2005 09:50:00 5 0.7 6.5 3.4 4.6 0.7 6.5 3 241 8 241 305 7.5 0 7.7 7.4 07/19/2005 10:00:00 5.7 0.6 7.2 4.2 5.3 0.6 6.8 3.8 238 6 238 305 7.5 0 7.7 7.4 07/19/2005 10:10:00 5.2 0.6 6.5 3.8 5.1 0.6 6.8 3.8 234 7 234 305 7.6 0 7.9 7.4 07/19/2005 10:20:00 5.1 0.4 6.1 3.8 4.8 0.5 6.1 3.4 241 8 247 305 7.6 0 7.7 7.7 07/19/2005 10:30:00 5 0.6 6.5 3.4 4.7 0.7 6.1 2.3 247 9 234 305 7.5 0 7.7 7.4 07/19/2005 10:40:00 5.5 0.6 6.8 3.8 5.2 0.7 6.5 3 245 8 241 305 7.5 0 7.7 7.4 07/19/2005 10:50:00 5.3 0.5 6.8 4.2 5.1 0.6 6.5 3.8 240 7 254 305 7.7 0 7.9 7.7 07/19/2005 11:00:00 5.4 0.6 6.8 3.8 5.2 0.6 6.8 3.8 237 7 232 305 7.9 0 7.9 7.7 07/19/2005 11:10:00 5.7 0.7 7.2 3.8 5.3 0.8 7.2 3.8 244 9 244 305 7.9 0 7.9 7.7 07/19/2005 11:20:00 4.9 0.6 6.5 3.4 4.7 0.6 6.1 3 240 7 236 305 7.9 0 8.2 7.7 07/19/2005 11:30:00 5.3 0.9 6.8 3 5 0.8 6.8 3.4 238 9 239 305 7.9 0 8.4 7.7 07/19/2005 11:40:00 5.3 0.5 6.5 3.8 5.1 0.5 6.5 3.8 232 7 227 305 7.9 0 8.4 7.7 07/19/2005 11:50:00 5.5 0.8 7.2 3.4 5.3 0.8 6.8 3.4 240 7 240 305 8 0 8.7 7.9 07/19/2005 12:00:00 5.7 0.7 7.2 4.2 5.4 0.7 6.8 3.8 230 8 229 305 8.2 0.1 8.9 7.9 07/19/2005 12:10:00 6 0.6 7.6 4.2 5.8 0.6 7.2 4.2 231 6 228 305 8.2 0 8.7 7.9 07/19/2005 12:20:00 5.8 0.6 7.2 4.2 5.5 0.6 6.8 4.2 238 6 240 305 8.2 0 8.7 7.9 07/19/2005 12:30:00 5.3 0.6 6.5 3.8 5 0.7 6.5 3.4 237 7 240 305 8.2 0 8.7 7.9 07/19/2005 12:40:00 4.4 0.5 5.7 3 4.2 0.5 5.3 3 228 9 238 305 8.2 0 8.4 8.2 07/19/2005 12:50:00 3.9 0.7 5.3 2.3 3.8 0.6 5.3 2.3 234 10 242 305 8.2 0 8.4 8.2 07/19/2005 13:00:00 4.5 0.5 5.7 3.4 4.3 0.5 5.3 3 235 8 230 305 8.2 0 8.4 8.2 07/19/2005 13:10:00 4.7 0.7 6.1 2.6 4.5 0.7 6.1 2.6 224 7 220 305 8.3 0.1 8.9 8.2 07/19/2005 13:20:00 4.8 0.6 6.5 3.4 4.5 0.7 6.1 3 223 9 218 305 8.5 0 9.2 8.2 07/19/2005 13:30:00 5.4 0.6 6.8 3.8 5.2 0.6 6.8 3.8 221 8 235 305 8.6 0 9.2 8.4 07/19/2005 13:40:00 5.5 0.6 6.8 3.8 5.3 0.6 6.8 3.4 227 6 219 305 8.3 0.1 8.7 8.2 07/19/2005 13:50:00 5.7 0.5 6.8 4.2 5.5 0.5 6.8 3 221 7 208 305 8.3 0 8.7 8.2 07/19/2005 14:00:00 5.4 0.5 6.5 3.8 5.2 0.6 6.5 3.8 232 6 229 305 8.3 0.1 8.9 8.2 07/19/2005 14:10:00 5.2 0.6 6.8 3.4 5 0.7 6.8 3 220 7 221 305 8.5 0 8.9 8.2 07/19/2005 14:20:00 5.7 0.6 7.2 4.2 5.5 0.7 6.8 3.4 219 6 221 305 8.4 0 8.9 8.2 07/19/2005 14:30:00 5.4 0.6 6.8 3.8 5.1 0.6 6.5 3 228 7 239 305 8.3 0.1 8.9 8.2 07/19/2005 14:40:00 5.6 0.6 7.2 4.2 5.3 0.6 6.8 3.8 227 6 234 305 8 0 8.7 7.7 07/19/2005 14:50:00 5.6 0.4 6.5 4.6 5.4 0.5 6.8 3.8 222 6 224 305 8.1 0 8.7 7.9 07/19/2005 15:00:00 5.9 0.5 7.2 4.2 5.8 0.5 7.2 3.8 222 4 225 305 8.1 0 8.7 7.9 07/19/2005 15:10:00 5.5 0.5 6.8 4.2 5.2 0.6 6.5 3.8 223 6 221 305 8.1 0.1 8.7 7.9 07/19/2005 15:20:00 5.6 0.6 7.2 3.8 5.4 0.7 7.2 3 217 7 232 305 8.1 0 8.4 7.9 07/19/2005 15:30:00 5.2 0.5 6.5 3.8 5 0.6 6.1 3.4 217 8 213 305 8 0 8.2 7.9 07/19/2005 15:40:00 5.4 0.5 6.5 3.8 5.2 0.6 6.5 3.8 217 5 218 305 8 0 8.2 7.9 07/19/2005 15:50:00 5.6 0.5 6.8 3.8 5.5 0.5 6.8 3.8 220 6 218 305 8 0 8.2 7.9 07/19/2005 16:00:00 5.5 0.6 6.8 4.2 5.3 0.6 6.5 3.8 222 6 218 305 7.8 0 8.2 7.7 07/19/2005 16:10:00 5 0.5 6.1 3.8 4.8 0.5 5.7 3.4 222 6 220 305 8 0 8.2 7.9 07/19/2005 16:20:00 5.5 0.7 7.2 4.2 5.2 0.7 6.8 3.4 221 7 221 305 8.1 0 8.2 7.9 07/19/2005 16:30:00 5.1 0.6 6.5 3.8 4.9 0.7 6.5 2.6 219 7 218 305 8.2 0.1 8.4 7.9 07/19/2005 16:40:00 5.4 0.5 6.8 3.8 5.2 0.5 6.5 3.8 225 8 231 305 8 0 8.4 7.9 07/19/2005 16:50:00 4.9 0.5 6.1 3.8 4.6 0.6 6.1 3 221 11 217 305 7.9 0.1 8.2 7.7 07/19/2005 17:00:00 4.8 0.7 6.5 3 4.5 0.7 6.5 3 228 9 227 305 7.6 0 7.9 7.7 07/19/2005 17:10:00 4.4 0.4 5.7 3 4.2 0.5 5.7 3 226 8 226 305 7.6 0 8.2 7.4 07/19/2005 17:20:00 4.5 0.4 5.7 3 4.3 0.5 5.7 3 229 7 224 305 7.6 0 8.2 7.4 07/19/2005 17:30:00 3.8 0.5 5.3 2.3 3.6 0.5 4.6 2.3 222 9 216 305 7.6 0.1 8.2 7.4 07/19/2005 17:40:00 3.4 0.5 4.9 2.3 3.3 0.6 5.3 1.9 219 10 214 305 7.6 0 8.2 7.4 07/19/2005 17:50:00 3.4 0.6 4.9 1.5 3.2 0.6 4.9 1.9 206 10 203 305 7.7 0.1 8.2 7.4 07/19/2005 18:00:00 2.5 0.7 4.2 0.7 2.4 0.7 4.6 1.1 215 16 211 305 7.7 0 8.2 7.7 07/19/2005 18:10:00 2.3 0.4 3.8 1.1 2.3 0.4 3.4 1.5 207 14 194 305 7.7 0.1 8.2 7.7 07/19/2005 18:20:00 2.4 0.4 3.8 1.1 2.3 0.4 3.4 1.1 220 10 210 305 7.5 0 8.2 7.4 07/19/2005 18:30:00 2.8 0.6 4.2 1.5 2.7 0.6 4.2 1.1 217 11 218 305 7.5 0 8.2 7.4 07/19/2005 18:40:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 219 8 224 305 7.3 0 7.7 7.2 07/19/2005 18:50:00 1.1 0.8 2.6 0.4 1.2 0.7 3 0.4 198 16 208 305 7.5 0 7.9 7.4 07/19/2005 19:00:00 2.1 0.4 3 0.7 2.1 0.3 3 1.1 219 9 218 305 7.6 0 8.2 7.7 07/19/2005 19:10:00 2 0.4 3 0.7 2 0.4 2.6 1.1 218 7 236 305 7.7 0.1 8.2 7.7 07/19/2005 19:20:00 1.7 0.4 3 0.7 1.7 0.3 2.3 0.7 218 10 211 305 7.8 0.1 8.4 7.7 07/19/2005 19:30:00 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 228 17 213 305 7.9 0 8.4 7.7 07/19/2005 19:40:00 0.8 0.6 2.6 0.4 0.9 0.7 2.6 0.4 286 66 18 305 8.2 0.1 8.7 7.9 07/19/2005 19:50:00 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 16 9 23 305 7.9 0.1 8.4 7.7 07/19/2005 20:00:00 1.8 0.5 3 0.7 1.9 0.5 3 0.7 7 9 5 305 7.8 0 8.2 7.7 07/19/2005 20:10:00 3 0.5 3.8 1.5 2.9 0.5 3.8 1.9 30 11 23 305 7.6 0 8.2 7.4 07/19/2005 20:20:00 3.3 0.4 4.2 1.9 3.3 0.4 4.2 2.3 40 6 44 305 7.5 0 7.9 7.4 07/19/2005 20:30:00 3.7 0.4 4.9 2.6 3.7 0.3 4.6 3 48 6 48 305 7.4 0 7.9 7.2 07/19/2005 20:40:00 3.5 0.7 5.3 1.5 3.6 0.7 4.9 1.5 43 11 43 305 7.3 0 7.9 7.2 07/19/2005 20:50:00 2.6 0.6 4.2 0.7 2.8 0.5 4.2 1.5 41 12 43 305 7.3 0 7.9 7.2 07/19/2005 21:00:00 2.7 0.8 4.2 0.7 3 0.6 4.9 1.1 47 14 43 305 7.4 0 7.7 7.2 07/19/2005 21:10:00 3.5 0.4 4.6 2.3 3.6 0.4 4.6 2.3 50 8 44 305 7.4 0 7.7 7.4 07/19/2005 21:20:00 3 0.9 4.9 0.7 3.1 0.8 4.9 1.1 57 27 39 305 7.7 0 7.9 7.4 07/19/2005 21:30:00 2.8 1.3 6.1 0.4 2.7 1.1 5.7 0.4 83 41 130 305 7.8 0 8.2 7.7 07/19/2005 21:40:00 6.3 0.8 8 4.6 6 0.9 8 3.8 138 6 137 305 8.4 0.1 8.7 7.9 07/19/2005 21:50:00 8.4 0.6 9.5 6.1 8.1 0.7 9.1 6.1 138 4 135 305 8.4 0.1 8.7 8.2 07/19/2005 22:00:00 8.6 0.5 9.5 6.5 8.3 0.5 9.5 6.5 139 4 144 305 8.1 0 8.2 7.9 07/19/2005 22:10:00 8.7 0.5 9.5 7.2 8.5 0.5 9.5 6.8 140 3 144 305 8 0 8.2 7.9 07/19/2005 22:20:00 8.7 0.5 9.5 7.2 8.3 0.5 9.5 6.8 140 4 138 305 7.8 0 7.9 7.7 07/19/2005 22:30:00 8.1 0.7 9.5 6.1 7.8 0.6 9.5 6.5 143 3 141 305 7.7 0 8.2 7.7 07/19/2005 22:40:00 8.5 0.5 9.5 7.2 8.1 0.5 9.1 6.5 143 2 141 305 7.5 0 7.7 7.4 07/19/2005 22:50:00 7.7 0.4 8.4 6.5 7.4 0.4 8.4 6.1 143 3 147 305 7.5 0 7.7 7.4 07/19/2005 23:00:00 7.7 0.4 8.4 6.5 7.5 0.4 8.4 6.1 141 3 139 305 7.3 0 7.4 7.2 07/19/2005 23:10:00 6.9 0.4 7.6 5.7 6.6 0.4 7.2 4.9 147 5 142 305 7.3 0 7.4 7.2 07/19/2005 23:20:00 6.3 0.8 8 4.2 6.1 0.6 7.6 4.6 149 6 144 305 7.2 0 7.4 7.2 07/19/2005 23:30:00 6.4 0.6 8 4.9 6.2 0.6 7.6 4.9 148 7 158 305 7 0 7.2 7.2 07/19/2005 23:40:00 6.6 0.8 8.4 4.6 6.4 0.8 7.6 4.6 144 8 151 305 7 0 7.2 6.9 07/19/2005 23:50:00 6.9 0.7 8.4 4.9 6.8 0.6 8.4 4.9 133 7 139 305 7 0 7.2 6.9 07/20/2005 00:00:00 5.7 0.6 7.6 4.2 5.7 0.6 7.2 4.2 117 8 122 305 7.2 0 7.4 7.2 07/20/2005 00:10:00 5.6 0.9 8 3.8 5.6 0.9 8 3.8 118 10 123 305 7.3 0 7.4 7.2 07/20/2005 00:20:00 5.4 1 7.6 3 5.3 0.9 7.2 3 112 11 121 305 7.3 0 7.4 7.2 07/20/2005 00:30:00 5.6 1.1 8.8 3 5.5 1 7.6 3 113 11 109 305 7.2 0 7.4 7.2 07/20/2005 00:40:00 5.9 1 8.4 3.8 5.8 0.9 8.4 3.4 118 11 121 305 7.3 0 7.4 7.2 07/20/2005 00:50:00 7.7 1.1 9.9 4.9 7.6 1 9.5 4.6 120 9 125 305 7.2 0 7.4 7.2 07/20/2005 01:00:00 7.9 1.1 10.7 4.9 7.8 1 10.7 5.3 119 9 123 305 7 0 7.4 6.9 07/20/2005 01:10:00 8.7 0.9 11.1 5.3 8.6 0.9 10.7 6.1 123 8 130 305 7.3 0 7.7 7.2 07/20/2005 01:20:00 8.2 0.8 10.3 6.1 8.2 0.8 10.3 6.1 123 9 127 305 7.6 0 7.7 7.4 07/20/2005 01:30:00 7.2 1.2 10.3 3.8 7.1 1.1 9.5 4.6 119 11 118 305 7.6 0 7.9 7.4 07/20/2005 01:40:00 7.1 1.1 12.2 4.2 6.9 1.1 11.8 4.6 113 15 137 305 7.4 0 7.7 7.2 07/20/2005 01:50:00 7.8 1 10.7 5.3 7.8 0.9 10.3 4.9 121 11 105 305 7.2 0 7.4 7.2 07/20/2005 02:00:00 8.8 1.1 11.8 6.1 8.6 1.1 11.5 5.7 119 10 127 305 7 0 7.2 6.9 07/20/2005 02:10:00 9.2 1 11.5 6.8 8.9 0.9 11.5 6.5 121 9 116 305 7 0 7.2 6.9 07/20/2005 02:20:00 8 1 10.7 5.7 7.8 1.1 10.7 4.9 124 11 135 305 7 0 7.2 6.9 07/20/2005 02:30:00 7.8 1 10.7 5.7 7.7 1 11.1 5.3 127 11 130 305 7.1 0 7.4 7.2 07/20/2005 02:40:00 7.6 1.1 10.3 4.6 7.5 1 10.3 4.6 129 13 139 305 7.2 0 7.4 7.2 07/20/2005 02:50:00 8.7 1.2 11.5 5.3 8.5 1.2 11.5 4.9 133 10 129 305 7.2 0 7.4 7.2 07/20/2005 03:00:00 7.4 1 9.9 4.2 7.3 1 9.9 4.6 129 12 123 305 7.1 0 7.4 7.2 07/20/2005 03:10:00 7 1 10.3 3.8 7 0.9 9.1 4.9 129 13 123 305 7.1 0 7.2 7.2 07/20/2005 03:20:00 7.5 1.2 11.1 4.2 7.3 1.1 10.3 4.2 124 12 112 305 7.1 0 7.2 7.2 07/20/2005 03:30:00 7.1 1.1 10.3 4.2 7 1.1 9.5 4.6 125 11 124 305 7.1 0 7.2 7.2 07/20/2005 03:40:00 7.1 1 10.3 4.9 6.9 1 9.5 4.6 119 11 117 305 7.2 0 7.4 7.2 07/20/2005 03:50:00 5.9 1.3 9.5 3 5.7 1.2 8.4 2.6 118 16 131 305 7.2 0 7.4 7.2 07/20/2005 04:00:00 7.2 1 9.9 4.2 7 0.9 9.5 3.8 125 11 120 305 7.3 0 7.4 7.2 07/20/2005 04:10:00 8 1.1 10.3 4.2 7.7 1.1 10.3 4.6 123 10 124 305 7.2 0 7.4 7.2 07/20/2005 04:20:00 7.5 1.2 10.7 4.6 7.2 1.1 10.3 3.8 122 10 128 305 7.2 0 7.4 7.2 07/20/2005 04:30:00 6.9 1.3 10.3 4.2 6.8 1.3 9.9 3.8 121 11 121 305 7.2 0 7.4 7.2 07/20/2005 04:40:00 6.3 1.2 9.9 3.4 6.1 1.2 8.8 3.8 130 13 109 305 7.1 0 7.4 7.2 07/20/2005 04:50:00 6.6 1 8.4 3.8 6.4 0.9 8.8 4.2 135 9 135 305 7 0 7.2 6.9 07/20/2005 05:00:00 6.2 1.1 9.9 3 6 1 9.5 3.4 127 15 109 305 7 0 7.2 7.2 07/20/2005 05:10:00 6.4 1.4 9.5 2.6 6.1 1.4 9.1 3 121 13 123 305 7.2 0 7.4 7.2 07/20/2005 05:20:00 5.7 1.5 9.5 2.3 5.6 1.7 9.9 1.9 116 17 120 305 7.2 0 7.4 7.2 07/20/2005 05:30:00 7.2 1.7 12.6 3.4 6.9 1.7 12.2 3.8 122 12 121 305 7.3 0 7.4 7.2 07/20/2005 05:40:00 5.9 1.7 11.1 2.6 5.9 1.7 10.3 2.6 133 15 118 305 7.5 0 7.7 7.4 07/20/2005 05:50:00 4.7 1.2 8.8 1.9 4.6 1.1 8 1.5 132 15 115 305 7.5 0 7.7 7.4 07/20/2005 06:00:00 4.9 1.2 8 1.5 4.6 1.2 8.4 1.9 109 23 110 305 7.5 0 7.7 7.4 07/20/2005 06:10:00 5.3 1.1 7.6 1.5 5.2 1 7.2 2.3 92 19 82 305 7.6 0 7.7 7.7 07/20/2005 06:20:00 5.5 0.9 8 3.4 5.3 0.8 7.6 3.8 99 12 96 305 7.7 0 7.9 7.7 07/20/2005 06:30:00 5 1.2 8 1.5 4.8 1.1 8 2.3 90 21 116 305 7.9 0 7.9 7.7 07/20/2005 06:40:00 5.2 1.2 7.6 2.6 5 1.2 8 2.3 95 21 76 305 7.7 0 7.9 7.7 07/20/2005 06:50:00 4.6 1.1 8.4 1.9 4.5 1 7.6 2.3 100 22 88 305 7.7 0 7.9 7.7 07/20/2005 07:00:00 5 1.3 8.8 2.3 4.7 1 8.8 1.9 103 22 124 305 7.5 0 7.7 7.4 07/20/2005 07:10:00 7 1.3 9.9 3.4 6.8 1.3 10.3 3.8 108 15 80 305 7.5 0 7.7 7.4 07/20/2005 07:20:00 6.4 1.1 9.9 3.4 6.1 1 9.1 3.4 99 17 122 305 7.6 0 7.7 7.4 07/20/2005 07:30:00 6.4 1.3 9.9 3 6.2 1.3 10.3 3 93 16 82 305 7.7 0 7.9 7.7 07/20/2005 07:40:00 5.5 1.3 8.4 2.3 5.4 1.2 8.8 2.6 81 22 75 305 7.9 0 8.2 7.7 07/20/2005 07:50:00 7.3 1.7 11.5 2.3 7.1 1.8 11.5 2.6 82 22 69 305 8 0 8.2 7.9 07/20/2005 08:00:00 7.3 1.6 12.2 3.8 6.9 1.8 11.8 3 87 20 89 305 8.1 0 8.4 7.9 07/20/2005 08:10:00 7.1 1.4 11.1 3.4 6.9 1.4 10.7 3.8 84 17 72 305 8.4 0 8.7 8.2 07/20/2005 08:20:00 6.3 1.5 10.7 2.6 6.1 1.5 11.5 3.4 84 20 60 305 8.5 0 8.7 8.4 07/20/2005 08:30:00 7.2 1.2 10.7 4.2 7.1 1.2 11.5 4.2 66 13 40 305 8.4 0 8.7 8.2 07/20/2005 08:40:00 7.3 1.7 11.5 4.2 7.3 1.8 12.6 3.4 66 19 51 305 8.6 0 8.7 8.4 07/20/2005 08:50:00 7.2 1.7 11.8 3.8 6.9 1.7 12.6 3 75 15 62 305 8.4 0 8.4 8.4 07/20/2005 09:00:00 7.4 1.7 12.2 3 7.2 1.8 12.2 2.3 75 18 87 305 8.4 0 8.7 8.2 07/20/2005 09:10:00 7.7 1.7 12.2 3.8 7.4 1.8 11.8 3.4 79 17 48 305 8.4 0 8.9 8.2 07/20/2005 09:20:00 8.7 1.1 11.5 5.7 8.4 1 11.5 4.9 82 9 55 305 8.4 0 8.4 8.2 07/20/2005 09:30:00 9.3 0.7 12.2 7.2 8.9 0.7 11.5 6.8 84 6 76 305 8.2 0 8.4 8.2 07/20/2005 09:40:00 9.2 0.8 11.8 6.5 8.8 0.9 11.8 5.7 85 7 82 305 8.2 0 8.4 8.2 07/20/2005 09:50:00 9.9 0.7 11.8 7.6 9.5 0.8 11.8 7.2 83 5 88 305 8.2 0 8.4 8.2 07/20/2005 10:00:00 10.1 0.7 12.2 7.6 9.7 0.8 11.8 7.2 83 6 77 305 8.1 0 8.2 7.9 07/20/2005 10:10:00 9.5 0.7 11.5 7.2 9.2 0.8 11.5 6.8 80 6 82 305 8.1 0 8.2 7.9 07/20/2005 10:20:00 9.6 0.9 12.2 7.2 9.2 0.9 11.1 6.8 81 7 80 305 8 0 8.2 7.9 07/20/2005 10:30:00 9.4 0.9 14.1 7.2 9 0.9 13.7 6.8 81 6 87 305 7.9 0 7.9 7.9 07/20/2005 10:40:00 9.4 1.2 13 6.1 9.1 1.3 12.2 5.7 76 11 82 305 7.9 0 8.2 7.9 07/20/2005 10:50:00 9 1.7 14.1 4.6 8.8 1.7 14.5 4.9 73 13 78 305 8 0 8.2 7.9 07/20/2005 11:00:00 9 1.5 13.3 4.6 8.8 1.7 13.3 4.6 74 16 88 305 8 0 8.2 7.9 07/20/2005 11:10:00 8.4 2 14.5 3.4 8.1 2 14.1 3 79 22 77 305 7.9 0 7.9 7.7 07/20/2005 11:20:00 8 1.9 13.7 3.4 8 2 13.3 3 75 19 62 305 7.8 0 7.9 7.7 07/20/2005 11:30:00 8.7 1.5 13 2.6 8.5 1.7 13 4.2 75 15 50 305 7.8 0 7.9 7.7 07/20/2005 11:40:00 9.1 1.6 13.7 5.7 8.9 1.7 14.1 5.7 74 13 77 305 7.9 0 7.9 7.7 07/20/2005 11:50:00 9.1 1.5 13.3 5.3 9.1 1.7 13.3 5.7 74 13 74 305 7.9 0 7.9 7.7 07/20/2005 12:00:00 8.6 1.8 13.7 4.6 8.7 1.7 14.1 4.6 77 15 70 305 7.9 0 7.9 7.7 07/20/2005 12:10:00 9 1.6 14.1 4.9 8.7 1.8 13.7 3.8 78 16 72 305 7.9 0 7.9 7.7 07/20/2005 12:20:00 9.1 1.5 13 5.3 8.8 1.5 12.2 4.9 77 14 57 305 7.8 0 7.9 7.7 07/20/2005 12:30:00 8.9 1.5 12.6 4.6 8.7 1.7 13 4.6 77 15 82 305 7.7 0 7.9 7.7 07/20/2005 12:40:00 8.8 1.7 13.3 4.6 8.6 1.7 13.7 4.6 80 13 61 305 7.7 0 7.9 7.7 07/20/2005 12:50:00 9.1 1.5 13 5.3 8.9 1.7 14.9 4.9 76 13 82 305 7.7 0 7.9 7.7 07/20/2005 13:00:00 9.6 1.1 13 6.1 9.4 1.1 13.7 6.8 79 11 72 305 7.9 0 8.2 7.7 07/20/2005 13:10:00 9.6 1 13 6.8 9.2 1.1 12.2 6.5 80 9 75 305 8 0 8.2 7.9 07/20/2005 13:20:00 9.7 1 12.6 5.3 9.4 1 13 6.5 82 8 101 305 8.1 0 8.2 7.9 07/20/2005 13:30:00 9.5 1.2 13.7 6.5 9.2 1.2 13.3 6.1 79 11 85 305 8.1 0 8.2 7.9 07/20/2005 13:40:00 9.8 1 13.7 6.8 9.6 1 13 6.5 77 9 77 305 8.2 0 8.4 8.2 07/20/2005 13:50:00 10 0.9 12.6 7.2 9.7 1 12.6 6.8 80 7 78 305 8.4 0 8.4 8.2 07/20/2005 14:00:00 10.6 0.8 13 8.4 10.3 0.9 13 7.2 79 6 73 305 8.4 0 8.4 8.2 07/20/2005 14:10:00 10.1 0.9 13 7.2 9.9 1 12.6 6.8 79 7 72 305 8.4 0 8.4 8.2 07/20/2005 14:20:00 9.6 1.3 12.6 5.3 9.5 1.2 12.2 5.7 79 9 75 305 8.4 0 8.4 8.2 07/20/2005 14:30:00 9.4 1.7 14.5 5.3 9.2 1.7 13.7 5.3 81 13 73 305 8.4 0 8.4 8.2 07/20/2005 14:40:00 9.5 1.7 13.7 5.7 9 1.8 14.9 4.6 81 12 90 305 8.4 0 8.4 8.2 07/20/2005 14:50:00 9.8 1.3 14.5 6.5 9.5 1.5 14.5 6.1 78 12 89 305 8.4 0 8.4 8.2 07/20/2005 15:00:00 10.3 1.2 13.7 6.8 10.1 1.2 13.7 6.8 81 9 64 305 8.4 0 8.4 8.2 07/20/2005 15:10:00 10.3 1.1 14.9 7.2 10 1.2 13.3 7.6 78 10 72 305 8.4 0 8.4 8.2 07/20/2005 15:20:00 10.6 1.7 15.6 6.1 10.3 1.8 15.6 5.3 80 12 78 305 8.4 0 8.4 8.2 07/20/2005 15:30:00 11.4 1.3 14.5 7.6 11.1 1.3 14.1 8.4 78 7 66 305 8.4 0 8.7 8.2 07/20/2005 15:40:00 11.5 1 14.5 8.8 11.1 1.1 14.1 8 79 6 81 305 8.4 0 8.7 8.2 07/20/2005 15:50:00 12.2 1.1 16.1 9.5 11.9 1.2 15.6 8.8 79 7 74 305 8.4 0 8.4 8.2 07/20/2005 16:00:00 11.7 1.1 14.5 8.8 11.3 1.2 15.6 7.6 79 6 82 305 8.4 0 8.4 8.2 07/20/2005 16:10:00 10.3 0.9 13 7.6 10.1 1 13 7.2 75 6 71 305 8.3 0 8.4 8.2 07/20/2005 16:20:00 9.8 1.1 13 5.3 9.5 1.1 12.2 6.8 73 8 64 305 8.2 0 8.4 8.2 07/20/2005 16:30:00 10.7 1.2 13.7 7.6 10.4 1.3 13.7 6.1 74 9 82 305 8.3 0 8.4 8.2 07/20/2005 16:40:00 10.1 1.8 15.6 6.1 10 1.9 15.6 5.3 74 12 66 305 8.3 0 8.4 8.2 07/20/2005 16:50:00 8.9 2.4 14.9 3.8 8.7 2.7 14.1 3 74 20 59 305 8.2 0 8.4 8.2 07/20/2005 17:00:00 9.1 2.4 16.1 3.4 8.8 2.4 14.1 3.8 70 20 71 305 8.2 0 8.4 8.2 07/20/2005 17:10:00 9.4 2.1 16.1 3.8 9.1 2.3 15.6 3 71 16 70 305 8.2 0 8.2 8.2 07/20/2005 17:20:00 9.4 1.6 14.5 4.9 9.2 1.7 14.1 5.3 69 13 60 305 8.2 0 8.7 8.2 07/20/2005 17:30:00 9.6 1.9 14.5 3.8 9.6 1.9 14.1 4.2 70 13 71 305 8.2 0 8.2 8.2 07/20/2005 17:40:00 9.9 2.1 16.4 4.2 9.8 2 14.9 4.9 70 17 58 305 8.2 0 8.4 8.2 07/20/2005 17:50:00 9.6 1.8 15.3 5.7 9.6 1.9 15.3 4.6 66 16 63 305 8.3 0 8.4 8.2 07/20/2005 18:00:00 9.9 1.7 14.9 5.7 9.6 1.8 14.9 5.7 70 14 71 305 8.4 0 8.4 8.2 07/20/2005 18:10:00 9.8 1.5 14.1 6.8 9.6 1.6 14.1 6.1 72 15 77 305 8.4 0 8.9 8.2 07/20/2005 18:20:00 10.3 1.4 14.5 7.2 10.1 1.5 13.7 6.5 75 11 59 305 8.2 0 8.4 8.2 07/20/2005 18:30:00 10.2 1.5 14.9 5.3 10.2 1.5 15.3 5.7 78 10 76 305 8.2 0 8.2 8.2 07/20/2005 18:40:00 9.8 1.7 16.1 6.1 9.8 1.8 14.5 5.3 71 13 82 305 8.2 0 8.2 8.2 07/20/2005 18:50:00 7.9 2 13.7 3.4 7.7 2.2 13.7 3 76 22 69 305 8.1 0 8.2 8.2 07/20/2005 19:00:00 8 2 12.6 2.3 7.7 2.1 11.8 2.6 73 20 63 305 8.1 0 8.2 7.9 07/20/2005 19:10:00 9 1.8 14.1 4.2 8.9 2 13.3 3.8 72 17 48 305 8.1 0 8.2 7.9 07/20/2005 19:20:00 8.9 2 14.9 4.6 8.7 2.1 14.9 3.4 71 17 76 305 8.1 0 8.2 7.9 07/20/2005 19:30:00 9.2 1.8 14.5 5.3 9 1.9 14.9 4.6 71 17 81 305 8.1 0 8.2 7.9 07/20/2005 19:40:00 8.1 2.3 13.3 3.4 7.7 2.3 13 3.4 76 20 80 305 8.2 0 8.2 7.9 07/20/2005 19:50:00 7.5 2 13 2.3 7.3 2.2 13.3 1.9 70 18 54 305 8.1 0 8.2 7.9 07/20/2005 20:00:00 6.6 1.6 11.5 3.4 6.7 1.7 12.2 3 64 18 48 305 8.2 0 8.4 8.2 07/20/2005 20:10:00 7.5 1.9 13.7 4.2 7.2 2 12.6 3.4 75 18 50 305 8.1 0 8.2 7.9 07/20/2005 20:20:00 7.1 1.7 11.8 3.4 6.6 1.8 11.8 3 81 22 77 305 8.1 0 8.2 7.9 07/20/2005 20:30:00 6.7 1.5 12.2 3 6.4 1.7 13 1.9 73 18 82 305 8.1 0 8.2 7.9 07/20/2005 20:40:00 7.4 2 12.2 2.6 7.2 2.2 13.3 2.6 72 17 80 305 8 0 8.2 7.9 07/20/2005 20:50:00 7.3 1.7 11.1 2.3 7.1 1.8 11.5 2.6 77 18 68 305 8 0 8.2 7.9 07/20/2005 21:00:00 7.5 1.3 10.7 4.2 7.3 1.4 11.8 3 78 15 82 305 8 0 8.2 7.9 07/20/2005 21:10:00 8.1 1.3 11.5 4.9 7.7 1.3 11.1 4.6 89 12 93 305 8 0 8.2 7.9 07/20/2005 21:20:00 7.6 1.6 12.2 3.4 7.2 1.7 12.2 3.4 88 15 87 305 8.1 0 8.2 7.9 07/20/2005 21:30:00 7.3 1 11.1 4.9 6.8 1 10.3 3.8 90 12 82 305 8.1 0 8.2 7.9 07/20/2005 21:40:00 6.8 1.3 10.7 3.4 6.6 1.2 9.5 3.8 84 15 90 305 8 0 8.2 7.9 07/20/2005 21:50:00 6 1.3 9.1 2.3 5.7 1.3 9.9 2.3 89 20 69 305 8 0 8.2 7.9 07/20/2005 22:00:00 6.5 1.2 9.9 3 6.2 1.2 9.5 3.8 93 14 92 305 7.9 0 8.2 7.7 07/20/2005 22:10:00 6.1 1 9.9 3.4 5.7 1 8.4 3.4 97 17 75 305 8 0 8.2 7.9 07/20/2005 22:20:00 6.4 0.9 8.4 4.2 5.9 0.9 8.4 3.4 92 14 101 305 8 0 8.2 7.9 07/20/2005 22:30:00 6.9 1.1 10.7 4.6 6.4 1.1 9.9 3.8 91 15 75 305 8.1 0 8.2 7.9 07/20/2005 22:40:00 7.1 0.9 9.9 4.9 6.7 1 9.9 4.6 87 10 66 305 8.1 0 8.7 7.9 07/20/2005 22:50:00 7.1 0.7 8.8 5.3 6.8 0.7 8.4 4.6 86 8 96 305 8.1 0 8.2 7.9 07/20/2005 23:00:00 7.5 0.5 8.8 6.1 7 0.5 8.8 4.9 86 5 82 305 8.1 0 8.2 7.9 07/20/2005 23:10:00 7.9 0.6 9.5 6.1 7.3 0.6 8.8 5.3 89 5 85 305 8.1 0 8.7 7.9 07/20/2005 23:20:00 7.8 0.6 9.1 5.7 7.2 0.6 8.4 5.3 88 5 80 305 8.1 0 8.2 7.9 07/20/2005 23:30:00 8.3 0.6 9.9 6.5 7.7 0.7 9.1 6.1 89 5 86 305 8 0 8.2 7.9 07/20/2005 23:40:00 8.5 0.8 10.3 5.7 8 0.8 9.9 5.3 84 6 89 305 8 0 8.2 7.9 07/20/2005 23:50:00 9.2 1 11.5 6.1 8.5 1 10.7 5.7 87 5 80 305 8.1 0 8.2 7.9 07/21/2005 00:00:00 9.1 1.2 11.5 5.3 8.5 1.2 11.1 6.1 87 8 94 305 8 0 8.7 7.9 07/21/2005 00:10:00 9.7 0.9 12.2 7.2 9.2 0.9 11.5 6.8 84 7 87 305 8.1 0 8.2 7.9 07/21/2005 00:20:00 9.6 0.8 12.6 7.6 9.2 0.9 12.6 7.2 82 7 87 305 8 0 8.2 7.9 07/21/2005 00:30:00 9.5 1 11.8 7.2 8.9 1 11.1 6.8 83 7 88 305 8 0 8.2 7.9 07/21/2005 00:40:00 10.3 0.8 13 8.4 9.9 0.9 12.6 8 78 6 75 305 8.1 0 8.2 7.9 07/21/2005 00:50:00 10.9 0.8 13.3 8.8 10.6 0.8 13 8.8 77 6 80 305 8.1 0 8.2 7.9 07/21/2005 01:00:00 10.1 0.9 13 8 9.6 1 13 6.8 78 6 80 305 8 0 8.2 7.9 07/21/2005 01:10:00 10.4 0.7 13 8.4 10 0.8 12.6 8 77 5 69 305 7.9 0 8.2 7.9 07/21/2005 01:20:00 9.9 0.7 11.8 8.4 9.7 0.7 12.2 8 75 5 79 305 7.9 0 7.9 7.9 07/21/2005 01:30:00 10.3 0.8 12.2 7.6 10 0.8 11.8 7.6 72 5 76 305 7.9 0 7.9 7.7 07/21/2005 01:40:00 10.8 0.6 12.2 9.1 10.6 0.8 12.2 8.4 75 5 70 305 7.8 0 7.9 7.7 07/21/2005 01:50:00 10.5 0.7 13 8.4 10.2 0.8 12.2 7.2 74 5 78 305 7.8 0 7.9 7.7 07/21/2005 02:00:00 10.5 0.6 12.2 8.8 10.2 0.8 12.2 8 74 5 69 305 7.7 0 7.9 7.7 07/21/2005 02:10:00 10.3 0.8 13.7 8.4 9.9 0.8 13 7.6 74 5 72 305 7.9 0 7.9 7.7 07/21/2005 02:20:00 10.3 0.8 12.6 8.4 10 0.9 12.6 8 75 6 72 305 7.9 0 7.9 7.7 07/21/2005 02:30:00 10.2 0.9 12.2 7.6 9.7 1 11.8 7.2 77 7 85 305 8 0 8.2 7.7 07/21/2005 02:40:00 10.2 0.8 13 8 9.9 0.8 12.2 8 74 5 74 305 7.9 0 8.2 7.7 07/21/2005 02:50:00 10.4 0.8 13.3 8.8 10 0.8 12.6 8 72 5 73 305 7.9 0 7.9 7.7 07/21/2005 03:00:00 10.6 0.8 13 8.8 10.3 0.9 12.6 8 72 6 70 305 7.8 0 7.9 7.7 07/21/2005 03:10:00 10.7 0.8 13.3 8.8 10.4 0.8 13.3 8.4 74 6 76 305 7.9 0 7.9 7.7 07/21/2005 03:20:00 11.2 0.7 13 9.1 10.9 0.7 13 8.8 73 5 71 305 7.9 0 7.9 7.7 07/21/2005 03:30:00 10.9 0.6 12.6 9.5 10.6 0.6 12.2 8.8 72 4 72 305 7.7 0 7.9 7.7 07/21/2005 03:40:00 10.7 0.5 11.8 8.8 10.2 0.5 11.5 8.4 70 4 70 305 7.6 0 7.7 7.7 07/21/2005 03:50:00 10.5 0.5 11.8 9.1 10 0.5 11.1 8.8 69 3 67 305 7.6 0 7.7 7.4 07/21/2005 04:00:00 9.9 0.5 11.5 8.8 9.5 0.5 11.1 7.6 68 3 66 305 7.5 0 7.7 7.4 07/21/2005 04:10:00 10.1 0.5 11.5 8.4 9.6 0.6 11.1 8 68 4 65 305 7.5 0 7.7 7.4 07/21/2005 04:20:00 10.1 0.6 11.5 8 9.6 0.8 11.8 7.6 66 5 68 305 7.5 0 7.7 7.4 07/21/2005 04:30:00 10.2 0.7 11.8 8.4 9.9 0.7 11.8 8 64 4 64 305 7.5 0 7.7 7.4 07/21/2005 04:40:00 9.1 0.7 11.5 7.2 8.7 0.6 10.3 6.5 63 5 76 305 7.5 0 7.7 7.4 07/21/2005 04:50:00 8.2 0.8 10.3 6.5 7.8 0.8 9.9 6.1 62 6 58 305 7.3 0 7.7 7.2 07/21/2005 05:00:00 8.9 0.6 10.7 7.2 8.6 0.6 10.7 7.2 65 5 60 305 7.5 0 7.7 7.4 07/21/2005 05:10:00 8.2 0.6 9.5 6.8 7.7 0.6 9.1 5.7 62 6 75 305 7.3 0.1 7.7 7.2 07/21/2005 05:20:00 8 0.6 9.5 6.1 7.5 0.6 9.1 5.3 62 5 54 305 7 0 7.4 6.9 07/21/2005 05:30:00 8.8 0.4 9.9 7.6 8.4 0.5 9.9 7.2 62 4 71 305 7 0 7.2 6.9 07/21/2005 05:40:00 8.7 0.5 10.3 7.2 8.2 0.6 10.3 6.5 64 4 65 305 7 0 7.2 6.9 07/21/2005 05:50:00 8.9 0.6 10.3 7.2 8.4 0.7 9.9 6.1 63 5 60 305 7 0 7.2 6.9 07/21/2005 06:00:00 8.2 0.4 9.5 7.2 7.7 0.5 9.5 6.5 62 4 57 305 7 0 7.2 6.9 07/21/2005 06:10:00 8.1 0.5 9.5 6.8 7.6 0.6 9.1 6.1 63 5 62 305 7 0 7.2 6.9 07/21/2005 06:20:00 8.5 0.7 10.3 6.5 8 0.8 9.9 5.7 65 6 70 305 7.2 0 7.4 7.2 07/21/2005 06:30:00 7.5 0.7 9.1 5.7 7.1 0.8 9.1 5.3 64 6 68 305 7.1 0 7.4 7.2 07/21/2005 06:40:00 7.3 0.6 9.5 5.7 6.9 0.7 8.4 5.3 62 6 62 305 7 0 7.4 6.9 07/21/2005 06:50:00 7.2 0.7 9.1 5.7 6.8 0.7 9.1 4.6 61 6 54 305 7 0 7.2 6.9 07/21/2005 07:00:00 7 0.7 9.1 4.9 6.7 0.6 8.4 4.9 60 7 55 305 7.2 0.1 7.7 6.9 07/21/2005 07:10:00 6.7 0.7 8.8 4.9 6.4 0.8 8.8 4.6 59 8 49 305 7.4 0 7.7 7.2 07/21/2005 07:20:00 6.2 0.7 8 4.2 5.9 0.7 8 4.2 58 7 71 305 7.2 0 7.4 7.2 07/21/2005 07:30:00 6.5 0.6 8.4 4.9 6.2 0.6 8.4 4.9 55 6 54 305 7.2 0 7.4 7.2 07/21/2005 07:40:00 6.4 0.7 9.1 5.3 6.2 0.7 8 4.9 55 6 53 305 7.2 0 7.4 7.2 07/21/2005 07:50:00 5.9 0.6 7.6 4.2 5.7 0.6 7.6 3.8 56 8 66 305 7.3 0 7.4 7.2 07/21/2005 08:00:00 5.7 0.7 7.6 4.2 5.4 0.6 7.2 3.8 58 8 51 305 7.3 0 7.4 7.2 07/21/2005 08:10:00 6.3 0.6 8 4.6 6.1 0.6 8.4 4.2 58 5 60 305 7.2 0 7.4 7.2 07/21/2005 08:20:00 6.5 0.5 8 5.3 6.2 0.6 8.4 4.6 55 5 61 305 7.2 0.1 7.7 7.2 07/21/2005 08:30:00 6.1 0.4 7.2 4.9 5.9 0.4 6.8 4.6 55 5 58 305 7 0 7.4 7.2 07/21/2005 08:40:00 6.1 0.4 7.6 5.3 5.9 0.4 7.2 4.9 57 5 59 305 7.2 0 7.4 7.2 07/21/2005 08:50:00 6.6 0.6 8 4.9 6.2 0.6 7.6 4.9 57 5 56 305 7.2 0 7.4 7.2 07/21/2005 09:00:00 6.7 0.4 8 5.7 6.5 0.4 8 4.9 59 4 54 305 7.2 0 7.4 7.2 07/21/2005 09:10:00 7.4 0.9 9.5 5.7 7 0.8 9.1 5.3 60 7 51 305 7.2 0 7.4 7.2 07/21/2005 09:20:00 8 0.5 9.1 6.5 7.2 0.6 8.8 5.7 52 5 58 305 7 0 7.4 6.9 07/21/2005 09:30:00 6.9 0.5 8 5.3 6.4 0.5 8 4.9 56 5 54 305 7 0 7.2 6.9 07/21/2005 09:40:00 6.4 0.4 7.6 5.3 6 0.4 6.8 4.9 56 5 56 305 7 0 7.2 6.9 07/21/2005 09:50:00 6.7 0.4 7.6 6.1 6.4 0.4 7.2 5.3 54 4 48 305 7 0 7.2 6.9 07/21/2005 10:00:00 6.2 0.4 7.2 5.3 6.1 0.4 7.2 4.9 58 4 53 305 7 0 7.2 6.9 07/21/2005 10:10:00 6.2 0.4 7.6 5.3 5.9 0.5 7.6 4.6 57 4 50 305 7 0 7.2 6.9 07/21/2005 10:20:00 6.4 0.4 8 4.9 6.3 0.5 7.6 4.9 58 4 52 305 7.1 0 7.4 7.2 07/21/2005 10:30:00 7 0.4 8.8 6.1 6.8 0.5 8.4 5.7 54 4 54 305 7.1 0 7.4 6.9 07/21/2005 10:40:00 6.7 0.5 8 5.3 6.4 0.5 7.6 5.3 59 4 55 305 7 0.1 7.4 6.9 07/21/2005 10:50:00 6.9 0.5 8 4.9 6.6 0.6 8.4 4.9 58 6 45 305 7.3 0 7.4 7.2 07/21/2005 11:00:00 6.3 0.6 8 4.9 5.9 0.6 7.6 4.2 57 6 62 305 7.4 0 7.7 7.2 07/21/2005 11:10:00 6 0.8 8.4 4.2 5.8 0.8 8 3.8 59 7 58 305 7.7 0.1 7.9 7.4 07/21/2005 11:20:00 5.6 0.7 7.2 4.2 5.3 0.7 7.2 3.4 57 8 61 305 7.7 0 7.9 7.7 07/21/2005 11:30:00 5.6 0.5 7.2 4.2 5.3 0.6 7.2 3.8 52 7 48 305 7.7 0 7.9 7.7 07/21/2005 11:40:00 5.5 0.7 7.6 3.8 5.2 0.7 7.6 3.8 51 8 45 305 7.7 0 7.9 7.7 07/21/2005 11:50:00 5.6 0.7 7.6 4.2 5.5 0.7 7.2 4.2 51 7 57 305 7.9 0 7.9 7.7 07/21/2005 12:00:00 5.6 0.8 7.6 3.8 5.5 0.8 7.6 3.4 53 8 58 305 7.9 0 8.2 7.7 07/21/2005 12:10:00 5.2 0.6 6.8 3.4 5 0.6 6.5 3.4 53 8 70 305 7.9 0 8.2 7.7 07/21/2005 12:20:00 5.3 0.7 6.8 3.4 5.1 0.7 6.8 3 52 8 38 305 8 0 8.2 7.9 07/21/2005 12:30:00 5.3 0.5 6.8 3.8 5.2 0.6 6.8 3.8 58 7 66 305 8.2 0 8.4 7.9 07/21/2005 12:40:00 5.5 0.6 6.8 4.2 5.4 0.6 6.8 4.2 60 7 73 305 8.2 0 8.4 8.2 07/21/2005 12:50:00 5.4 0.5 6.8 4.2 5.3 0.5 6.8 3.8 60 7 62 305 8.2 0 8.7 8.2 07/21/2005 13:00:00 6 0.6 8.4 4.6 5.8 0.6 7.2 4.2 60 7 47 305 8.2 0 8.4 7.9 07/21/2005 13:10:00 6.8 0.6 8.4 5.3 6.5 0.6 8.4 4.9 59 7 53 305 8.1 0 8.2 7.9 07/21/2005 13:20:00 6.9 0.6 8 5.3 6.7 0.6 8.4 5.3 61 6 53 305 8.2 0.1 8.4 7.9 07/21/2005 13:30:00 7.2 0.6 8.8 5.7 7 0.6 8.4 5.3 60 7 62 305 8.2 0 8.4 8.2 07/21/2005 13:40:00 7.2 0.5 8.4 5.7 7 0.5 8.4 5.3 55 5 56 305 8.2 0 8.4 7.9 07/21/2005 13:50:00 7.7 0.6 9.5 6.1 7.8 0.6 9.5 6.1 55 5 56 305 8.3 0 8.4 8.2 07/21/2005 14:00:00 7.4 0.6 9.5 5.3 7.4 0.6 9.1 5.3 53 5 55 305 8.2 0 8.4 8.2 07/21/2005 14:10:00 6.1 0.6 7.6 4.9 6 0.7 7.6 4.2 50 7 52 305 8.2 0 8.4 8.2 07/21/2005 14:20:00 5.6 0.6 7.2 3.8 5.5 0.7 7.2 3.4 49 7 57 305 8.2 0 8.4 8.2 07/21/2005 14:30:00 5 0.7 7.6 3.4 4.8 0.7 6.8 3 47 8 48 305 8.3 0 8.4 8.2 07/21/2005 14:40:00 4.6 0.7 7.2 3 4.3 0.7 6.8 3 48 9 58 305 8.4 0 8.4 8.2 07/21/2005 14:50:00 5.8 1.2 8.4 3 5.4 1.2 8 3 52 7 45 305 8.3 0.1 8.7 8.2 07/21/2005 15:00:00 7.9 0.6 9.9 6.1 8 0.7 9.9 6.5 55 5 61 305 8.7 0 8.9 8.4 07/21/2005 15:10:00 8.8 1.1 11.8 5.7 8.7 1 11.5 4.9 53 6 43 305 8.8 0 8.9 8.7 07/21/2005 15:20:00 7 0.6 8.8 5.7 6.8 0.6 8.4 5.7 51 6 57 305 8.8 0 8.9 8.7 07/21/2005 15:30:00 7.4 0.6 8.8 6.1 7 0.5 8.4 5.3 51 6 58 305 8.6 0 8.9 8.4 07/21/2005 15:40:00 7.6 1 9.9 5.3 7.2 0.8 9.1 4.9 53 6 52 305 8.6 0 8.7 8.4 07/21/2005 15:50:00 7 1 9.9 4.6 6.6 1 9.5 4.2 49 6 44 305 8.6 0 8.9 8.4 07/21/2005 16:00:00 6.6 0.5 8 5.3 6.1 0.5 7.6 4.6 47 5 46 305 8.6 0 8.7 8.4 07/21/2005 16:10:00 6.7 0.6 8.4 4.9 6.1 0.6 7.6 4.6 49 5 46 305 8.5 0 8.7 8.4 07/21/2005 16:20:00 7.6 1 10.7 5.7 7 1 10.3 4.9 50 5 40 305 8.5 0 8.9 8.4 07/21/2005 16:30:00 8 0.9 9.9 5.3 7.4 1 9.9 4.2 50 8 54 305 8.8 0 8.9 8.7 07/21/2005 16:40:00 8.2 1.1 11.1 5.3 7.8 1.2 11.1 4.9 52 8 51 305 9.1 0 9.2 8.9 07/21/2005 16:50:00 8.6 1.1 11.5 5.7 8.1 1.3 11.5 5.3 61 10 57 305 9.1 0 9.2 8.9 07/21/2005 17:00:00 10.1 1.2 13.3 6.8 9.6 1.1 13 6.1 65 7 71 305 9.3 0 9.5 9.2 07/21/2005 17:10:00 9.7 1.2 12.6 6.8 8.9 1.3 12.2 5.3 64 8 66 305 9.3 0 9.5 9.2 07/21/2005 17:20:00 11.5 1.3 14.9 8.4 10.6 1.3 14.1 7.6 66 7 78 305 9.4 0 9.5 9.2 07/21/2005 17:30:00 11.3 1.2 14.5 7.6 10.5 1.3 13.7 7.2 67 8 73 305 9.2 0 9.5 9.2 07/21/2005 17:40:00 11.1 1.5 15.3 8 10.7 1.5 14.1 7.2 77 10 76 305 10 0.4 11 9.2 07/21/2005 17:50:00 10.4 1.6 14.5 6.1 10 1.6 16.1 5.7 79 12 90 305 10.6 0 11.3 10.5 07/21/2005 18:00:00 10 1.4 16.8 6.5 9.4 1.3 15.3 6.5 74 12 90 305 10.3 0.2 11 9.7 07/21/2005 18:10:00 10.2 1.6 14.5 6.5 9.9 1.5 14.5 6.5 77 12 81 305 10.4 0.1 10.8 10 07/21/2005 18:20:00 9.3 1.8 15.3 3 8.9 1.8 14.1 4.2 76 15 89 305 10.8 0.1 11 10.5 07/21/2005 18:30:00 8.3 1.8 14.5 4.6 7.8 1.7 12.6 4.2 84 13 120 305 10.6 0 10.8 10.5 07/21/2005 18:40:00 8.8 1.6 14.1 5.3 8.5 1.5 13.7 4.9 77 13 76 305 10.8 0.2 11 10.2 07/21/2005 18:50:00 9 2.1 15.6 4.9 8.3 1.9 15.6 4.2 90 16 98 305 10.7 0.3 11.3 10.2 07/21/2005 19:00:00 7.4 2.1 15.3 3.4 7.1 2.1 15.3 3 94 21 113 305 11.9 0.2 12.4 11.3 07/21/2005 19:10:00 7.6 2.3 14.5 3.4 7.2 2.3 13.3 1.9 80 26 67 305 12.4 0 12.6 12.1 07/21/2005 19:20:00 5.5 1.4 12.2 3 5.4 1.3 12.2 2.6 61 20 84 305 9.9 1 12.1 9.2 07/21/2005 19:30:00 5.6 0.8 8.8 3.8 5.4 0.8 8.4 3.4 52 13 49 305 9.9 0.4 10.8 9.2 07/21/2005 19:40:00 6.6 0.9 9.1 4.6 6.4 1 8.8 3.8 46 11 38 305 9.5 0.2 10 9.2 07/21/2005 19:50:00 6 1.3 9.1 2.3 5.7 1.3 8.8 1.9 43 12 49 305 9.5 0 10.2 9.2 07/21/2005 20:00:00 7.8 1 10.3 4.9 7.5 1 9.9 4.6 58 10 67 305 10.2 0.3 10.8 9.7 07/21/2005 20:10:00 6.7 1 9.1 4.2 6.2 1 8.8 4.2 39 8 50 305 9.7 0.4 10.8 9.2 07/21/2005 20:20:00 6 0.9 8.8 3.4 5.5 0.9 8 2.6 47 12 41 305 9.1 0 9.5 8.9 07/21/2005 20:30:00 6.8 1.1 9.5 4.2 6.4 0.9 8.8 3.8 45 8 49 305 9.3 0 10 9.2 07/21/2005 20:40:00 7 0.8 9.5 4.9 6.7 0.8 9.1 4.6 48 7 44 305 9.1 0 9.7 8.9 07/21/2005 20:50:00 6.6 0.9 8.8 4.2 6.2 0.8 8.4 4.2 43 9 45 305 9.1 0.1 9.7 8.7 07/21/2005 21:00:00 7.5 0.8 9.9 5.7 7.2 0.9 9.5 4.6 42 8 49 305 8.7 0.2 9.5 8.2 07/21/2005 21:10:00 7.6 1.2 10.3 4.9 7.1 1.2 10.3 4.2 45 9 39 305 8.2 0.1 8.9 8.2 07/21/2005 21:20:00 7.7 1 10.3 4.9 7.4 1 9.9 4.6 41 9 44 305 8.6 0 9.2 8.2 07/21/2005 21:30:00 7.3 1 10.3 4.9 7 1 9.9 4.2 44 9 66 305 8.5 0 9.2 8.4 07/21/2005 21:40:00 7.5 1.1 9.9 4.9 7.1 1.1 9.9 4.2 45 9 45 305 8.6 0 9.2 8.4 07/21/2005 21:50:00 7.4 0.8 9.1 5.3 7.3 0.8 9.5 4.6 44 10 50 305 8.6 0 9.2 8.4 07/21/2005 22:00:00 7.9 1.2 11.5 4.9 7.6 1.1 10.3 5.3 43 9 44 305 8.7 0 9.2 8.4 07/21/2005 22:10:00 7.6 1.1 10.3 4.9 7.2 1.1 9.9 4.6 46 9 41 305 8.6 0 8.9 8.4 07/21/2005 22:20:00 8.1 1 10.3 4.9 7.9 1 10.7 4.6 46 9 50 305 8.7 0 8.9 8.4 07/21/2005 22:30:00 8.1 1 11.5 6.1 7.7 1 10.7 5.7 46 9 43 305 8.8 0 8.9 8.7 07/21/2005 22:40:00 8.7 1.1 11.5 6.1 8.3 1.1 12.2 4.9 48 9 44 305 8.9 0 9.5 8.9 07/21/2005 22:50:00 8.8 1.1 12.6 6.5 8.6 1.1 11.5 6.1 45 8 30 305 9 0 9.2 8.9 07/21/2005 23:00:00 8.3 1.2 11.5 5.3 8 1.2 10.3 4.9 46 9 34 305 8.9 0 9.2 8.7 07/21/2005 23:10:00 8.8 1.1 12.2 5.7 8.3 1.1 11.1 5.7 44 8 44 305 9.1 0.1 9.5 8.7 07/21/2005 23:20:00 8.8 1.4 12.6 4.9 8.4 1.3 11.8 4.6 45 9 59 305 9.4 0.1 9.7 9.2 07/21/2005 23:30:00 8.4 1.4 12.2 4.9 8.1 1.3 11.5 4.6 44 9 46 305 9.6 0.1 10 9.5 07/21/2005 23:40:00 8.1 1.1 11.1 5.7 7.8 1.1 10.3 5.3 42 8 31 305 9.6 0 9.7 9.5 07/21/2005 23:50:00 8 1.2 11.5 5.3 7.7 1.2 11.1 4.9 44 9 40 305 9.5 0.1 10 9.2 07/22/2005 00:00:00 8.1 1.1 11.1 5.7 7.8 1.2 11.5 5.3 45 10 32 305 9.7 0 10 9.5 07/22/2005 00:10:00 7.9 1 10.3 4.9 7.5 1 10.7 4.6 45 8 48 305 9.7 0 10 9.5 07/22/2005 00:20:00 7.8 1.2 10.3 4.6 7.5 1.2 11.1 4.6 45 9 48 305 9.7 0 10 9.5 07/22/2005 00:30:00 8 1.1 11.5 5.7 7.5 1.1 10.3 4.6 44 9 48 305 9.6 0 9.7 9.5 07/22/2005 00:40:00 8.6 1.3 12.6 5.3 8.2 1.3 14.1 5.7 46 9 50 305 9.7 0 10.2 9.5 07/22/2005 00:50:00 9.1 1.3 13 6.1 8.5 1.2 12.6 5.7 47 9 47 305 10.1 0.1 10.5 9.7 07/22/2005 01:00:00 8.1 1.2 12.2 5.7 7.8 1.1 11.8 5.7 49 8 37 305 9.9 0 10 9.7 07/22/2005 01:10:00 7.9 1 11.1 5.7 7.5 1 11.1 5.3 53 7 44 305 9.9 0 10.2 9.7 07/22/2005 01:20:00 8.7 1.2 11.8 6.1 8.3 1.1 11.5 5.7 49 8 52 305 10.2 0.2 10.8 9.7 07/22/2005 01:30:00 7.9 1 11.1 5.7 7.6 1.1 12.6 5.3 46 8 46 305 10.1 0 10.5 9.7 07/22/2005 01:40:00 6.7 0.8 9.1 4.9 6.5 0.8 9.1 4.6 45 7 29 305 9.7 0.1 10.2 9.5 07/22/2005 01:50:00 6.5 0.8 9.5 4.6 6.2 0.8 9.1 4.2 48 10 40 305 9.7 0 10 9.5 07/22/2005 02:00:00 7.1 1 9.9 4.9 6.8 1 9.5 4.6 44 9 41 305 9.7 0 10 9.5 07/22/2005 02:10:00 6.9 0.9 9.9 4.9 6.6 0.9 9.5 4.6 48 9 45 305 9.5 0.1 9.7 9.2 07/22/2005 02:20:00 6.3 1 9.1 4.6 6 1 9.1 4.2 56 8 57 305 9.5 0 9.7 9.2 07/22/2005 02:30:00 7.1 0.9 10.3 5.7 6.9 0.8 9.5 5.3 51 7 43 305 9.3 0 9.5 9.2 07/22/2005 02:40:00 7.5 0.8 10.3 5.3 7.2 0.7 10.3 5.3 51 8 54 305 9.3 0.1 9.7 9.2 07/22/2005 02:50:00 7.7 1 10.7 4.9 7.4 1 10.3 4.9 54 9 61 305 9.5 0.1 10 9.2 07/22/2005 03:00:00 8.4 1 11.5 6.5 8.1 0.9 11.1 6.5 57 7 66 305 9.9 0 10.2 9.5 07/22/2005 03:10:00 8.5 0.8 11.5 6.8 8.2 0.8 11.1 6.5 60 6 62 305 9.9 0 10.2 9.7 07/22/2005 03:20:00 9.1 0.9 11.8 6.8 8.6 0.9 11.5 6.5 59 6 63 305 10.2 0 10.5 10 07/22/2005 03:30:00 7.9 1.1 10.7 5.7 7.6 1 9.9 5.7 58 6 68 305 9.8 0.1 10.2 9.5 07/22/2005 03:40:00 8.7 1 11.5 6.5 8.3 1 10.7 5.7 58 7 64 305 9.8 0 10 9.7 07/22/2005 03:50:00 8.7 0.9 11.1 6.8 8.4 0.8 10.7 6.5 57 6 64 305 9.9 0 10.2 9.7 07/22/2005 04:00:00 9 1.2 13 6.5 8.6 1.2 11.8 6.5 60 7 72 305 10.1 0.1 10.2 9.7 07/22/2005 04:10:00 9.6 1 12.2 7.2 9.1 1.1 12.2 6.5 60 7 73 305 10.2 0 10.2 10 07/22/2005 04:20:00 10.1 1.1 13.7 7.6 9.7 1.1 13.7 7.6 64 7 68 305 10.5 0.2 11 10 07/22/2005 04:30:00 11.1 0.9 13.3 8.8 10.5 0.9 12.6 8.8 65 5 66 305 10.3 0.1 10.5 10 07/22/2005 04:40:00 11.6 1 14.1 9.1 11 0.9 13.7 9.1 67 5 70 305 10.4 0 10.5 10.2 07/22/2005 04:50:00 12.4 1 15.3 9.1 11.9 1 15.3 8.4 75 5 72 305 11.6 0.6 12.9 10.5 07/22/2005 05:00:00 13 1.1 16.1 10.3 12.6 1.2 16.1 9.5 75 6 72 305 12.5 0.2 13.2 12.1 07/22/2005 05:10:00 12.9 1 15.3 10.3 12.3 1 14.9 9.9 75 6 80 305 12.6 0.1 13.2 12.4 07/22/2005 05:20:00 12.1 1.2 16.1 9.1 11.6 1.2 15.3 8.8 84 7 85 305 12.4 0 12.9 12.1 07/22/2005 05:30:00 11.7 1.3 15.6 7.6 11.2 1.3 14.5 7.2 82 7 74 305 12.5 0 12.9 12.4 07/22/2005 05:40:00 11.6 1.3 14.9 8.8 11.1 1.3 14.5 8 82 6 82 305 12.7 0 13.2 12.4 07/22/2005 05:50:00 11.4 1.1 14.1 8.8 10.7 1.1 13.3 7.6 84 7 78 305 12.4 0 12.6 12.4 07/22/2005 06:00:00 10.8 1.2 13.7 8 10.3 1.2 13.7 7.2 85 7 96 305 12.5 0 13.2 12.4 07/22/2005 06:10:00 11.5 1.2 14.5 8 10.8 1.2 14.1 7.2 87 7 85 305 12.2 0.1 12.9 11.8 07/22/2005 06:20:00 11.4 1.2 13.7 8.4 10.7 1.2 13.3 7.6 85 6 87 305 12.2 0 12.4 11.8 07/22/2005 06:30:00 10.2 1.3 13.3 6.8 9.7 1.3 13 5.3 92 9 93 305 12 0 12.4 11.8 07/22/2005 06:40:00 10.2 1.2 13 7.2 9.7 1.1 11.8 6.5 95 7 96 305 11.8 0 12.4 11.6 07/22/2005 06:50:00 10.5 0.9 12.6 8 9.9 0.9 12.2 7.6 96 6 95 305 11.6 0.1 11.8 11.3 07/22/2005 07:00:00 10.4 0.8 12.2 8.4 9.8 0.8 11.8 8 100 5 96 305 11.2 0 11.6 11 07/22/2005 07:10:00 10.6 0.8 12.2 8.4 10.1 0.8 11.8 8 105 5 108 305 11 0.1 11.3 10.8 07/22/2005 07:20:00 9.9 0.6 11.8 8.4 9.6 0.6 11.1 8 109 5 113 305 11 0 11.3 10.8 07/22/2005 07:30:00 9.2 0.5 10.7 8 8.8 0.6 10.7 6.8 112 4 105 305 11.1 0 11.6 11 07/22/2005 07:40:00 8.6 0.4 9.5 7.6 8.1 0.5 9.5 6.8 113 3 114 305 11.4 0 11.8 11.3 07/22/2005 07:50:00 8.5 0.4 9.5 7.6 8.1 0.5 9.5 6.8 111 3 117 305 11.4 0 11.6 11.3 07/22/2005 08:00:00 8 0.3 9.1 7.2 8.1 0.4 9.1 6.8 115 2 112 305 11.3 0 11.3 11 07/22/2005 08:10:00 6.7 0.5 7.6 5.7 6.5 0.5 7.6 5.3 120 1 118 305 11.8 0.2 12.1 11.3 07/22/2005 08:20:00 6 0.2 6.5 5.3 5.9 0.3 6.5 4.9 121 2 120 305 12.1 0 12.4 11.8 07/22/2005 08:30:00 4.9 1.1 6.8 1.5 4.5 1.2 6.5 0.7 124 8 120 305 12.6 0.3 13.2 12.1 07/22/2005 08:40:00 2.6 1.2 4.9 0.4 2.1 1 4.6 0.4 147 43 113 305 12.5 0.2 13.2 12.1 07/22/2005 08:50:00 3.7 0.9 5.3 0.4 3.3 1.1 4.9 0.4 128 17 128 305 12.9 0.2 13.2 12.4 07/22/2005 09:00:00 1.1 0.5 2.3 0.4 1.4 0.6 3 0.4 294 35 309 305 11.5 0.6 12.9 10.8 07/22/2005 09:10:00 1.3 1.1 4.9 0.4 1.7 1.1 5.3 0.4 299 72 1 305 10.6 0.4 11.3 9.7 07/22/2005 09:20:00 2 1.1 4.9 0.4 2.6 1.2 5.7 0.4 336 53 18 305 9.5 0 9.7 9.2 07/22/2005 09:30:00 3.4 1.7 6.5 0.4 3.2 1.8 6.1 0.4 123 47 138 305 10.6 0.8 12.6 9.7 07/22/2005 09:40:00 4.7 0.7 6.8 3 4.6 0.7 6.5 3 135 10 128 305 13.6 0.4 14.3 12.6 07/22/2005 09:50:00 5.3 0.8 7.6 3.8 5.1 0.8 7.2 3 131 10 141 305 14 0 14.3 14 07/22/2005 10:00:00 5.4 0.7 7.2 3.8 5.2 0.7 7.2 3.4 129 9 123 305 14 0 14.3 14 07/22/2005 10:10:00 4.8 1 7.6 2.6 4.7 1 7.2 2.3 125 12 132 305 14.3 0 14.5 14.3 07/22/2005 10:20:00 3.3 1 6.1 0.4 2.9 1.2 6.1 0.4 138 38 122 305 13.9 0.7 14.5 12.1 07/22/2005 10:30:00 1 0.5 3 0.4 1.5 0.7 3.8 0.4 133 98 200 305 10.1 1 12.1 8.9 07/22/2005 10:40:00 1.2 0.6 2.6 0.4 1.3 0.7 3 0.4 95 66 330 305 10 1 11.3 8.7 07/22/2005 10:50:00 2.4 0.8 4.2 0.4 2.3 0.8 4.6 0.4 115 21 114 305 12.7 1 14.5 11 07/22/2005 11:00:00 2.9 0.8 5.7 0.7 2.8 0.8 4.6 1.1 96 23 91 305 15.1 0.3 15.6 14.5 07/22/2005 11:10:00 2.6 0.8 4.2 0.4 2.6 0.7 4.2 0.4 91 17 106 305 14.5 0.2 15.1 14.3 07/22/2005 11:20:00 3 0.8 4.9 1.1 2.9 0.7 4.6 1.5 93 22 102 305 15.2 0 15.6 15.1 07/22/2005 11:30:00 2.7 0.8 4.9 0.7 2.7 0.6 4.6 1.1 77 20 73 305 15.3 0 15.6 15.1 07/22/2005 11:40:00 3.2 0.8 5.3 1.5 3.2 0.8 4.9 1.1 76 13 69 305 13.4 1.4 15.3 11.3 07/22/2005 11:50:00 3.6 0.5 4.6 2.6 4 0.5 5.3 2.6 71 11 63 305 10.7 0.4 11.6 10.2 07/22/2005 12:00:00 4.5 0.7 6.1 2.6 5 0.6 6.1 3.4 67 9 54 305 10.2 0.3 10.8 10 07/22/2005 12:10:00 4.4 0.5 6.1 3.4 4.5 0.5 6.1 3.4 72 9 90 305 11 0 11.3 10.8 07/22/2005 12:20:00 4.5 0.5 6.5 3 4.9 0.5 6.1 3.8 70 8 69 305 11.1 0.2 11.6 10.8 07/22/2005 12:30:00 4.3 0.4 5.7 3 4.9 0.5 6.1 3 61 7 65 305 11.3 0 11.6 11 07/22/2005 12:40:00 4.3 0.3 5.3 3.8 4.8 0.3 5.7 4.2 59 4 68 305 11.2 0 11.3 11 07/22/2005 12:50:00 4.4 0.4 5.3 3.4 5.1 0.5 6.1 3.8 52 5 45 305 11 0.2 11.6 10.5 07/22/2005 13:00:00 4.3 0.2 4.9 3.8 4.9 0.4 5.7 4.2 52 3 53 305 11.6 0 11.6 11.3 07/22/2005 13:10:00 4.3 0.2 4.9 3.8 4.8 0.3 5.7 4.2 55 3 59 305 11.6 0 11.8 11.3 07/22/2005 13:20:00 4.4 0.3 5.3 3.8 5.1 0.4 6.1 4.2 54 3 45 305 12.1 0.2 12.6 11.8 07/22/2005 13:30:00 4.2 0.5 5.3 3.4 4.1 0.5 5.3 3 66 11 62 305 13.2 0.2 13.7 12.9 07/22/2005 13:40:00 3.9 0.4 5.3 2.6 3.9 0.4 4.9 2.6 56 7 54 305 13.2 0 13.4 13.2 07/22/2005 13:50:00 4.2 0.5 5.7 3 4.1 0.4 5.3 3 59 6 59 305 13.4 0.1 14 13.2 07/22/2005 14:00:00 4 0.4 4.9 3 4.1 0.4 5.3 3 59 6 65 305 13.3 0.2 13.7 12.6 07/22/2005 14:10:00 4.2 0.3 4.9 3.4 4.6 0.4 5.7 3.8 61 4 62 305 12.6 0 12.9 12.4 07/22/2005 14:20:00 4.3 0.4 5.3 3 5.1 0.4 6.1 3.8 58 5 53 305 12 0.2 12.6 11.6 07/22/2005 14:30:00 4.4 0.4 5.7 3 4.9 0.4 5.7 3.4 54 8 48 305 12 0.3 12.4 11.3 07/22/2005 14:40:00 4.8 0.5 6.1 3 5.1 0.5 6.1 3.4 47 7 43 305 12.2 0.1 12.4 11.6 07/22/2005 14:50:00 5.4 0.7 7.2 3.8 5.9 0.8 7.2 4.2 47 7 54 305 11.6 0.1 11.8 11.3 07/22/2005 15:00:00 6.4 0.3 7.2 5.3 6.6 0.3 7.2 6.1 45 5 42 305 11.4 0 11.8 11 07/22/2005 15:10:00 6.5 0.3 7.2 5.7 6.5 0.3 6.8 5.3 38 6 42 305 11 0.1 11.3 10.8 07/22/2005 15:20:00 6.5 0.6 7.6 4.9 6.6 0.5 7.6 4.6 44 10 41 305 11 0 11.3 10.8 07/22/2005 15:30:00 5.9 0.6 7.2 4.2 6.3 0.7 7.6 4.6 39 7 36 305 11.3 0 11.6 11 07/22/2005 15:40:00 6.6 0.6 8.4 5.3 6.8 0.5 8 5.3 42 8 55 305 11.4 0.3 12.1 11 07/22/2005 15:50:00 6.8 0.8 8.8 3.8 6.8 1 8.8 3.4 55 16 48 305 12 0.1 12.9 11.6 07/22/2005 16:00:00 6.2 0.8 8.4 3.8 6.1 1 8.4 3.8 66 17 42 305 13 0.6 14 11.8 07/22/2005 16:10:00 6.7 0.6 8.4 4.9 7 0.6 8.4 4.9 48 12 46 305 11.4 0.3 11.8 11 07/22/2005 16:20:00 7.5 0.9 9.1 4.9 7.8 0.6 8.8 5.3 48 7 42 305 10.7 0.2 11 10.2 07/22/2005 16:30:00 8 0.4 9.1 6.8 8 0.4 8.8 6.8 47 4 50 305 10.6 0 10.8 10.5 07/22/2005 16:40:00 7.5 0.3 8 6.1 7.6 0.2 8.4 6.8 46 4 45 305 10.8 0 11 10.5 07/22/2005 16:50:00 7.3 0.7 8.8 5.3 7.3 0.8 8.4 4.9 54 14 39 305 11 0.3 11.8 10.8 07/22/2005 17:00:00 7.4 0.8 9.1 5.3 6.9 0.8 8.4 4.9 79 8 77 305 13.6 1 14.8 11.6 07/22/2005 17:10:00 7.7 0.7 9.5 6.1 7.3 0.6 8.8 5.7 84 6 80 305 14.5 0 15.1 14.3 07/22/2005 17:20:00 7.5 0.7 9.1 5.7 7.1 0.7 8.8 4.9 86 7 87 305 14.4 0 14.8 14.3 07/22/2005 17:30:00 8.3 0.7 9.9 6.5 7.8 0.8 9.5 5.7 91 6 89 305 14.5 0 14.8 14.3 07/22/2005 17:40:00 7.5 0.8 9.9 5.3 7.1 0.8 9.5 4.6 87 10 89 305 14.7 0.1 15.1 14.5 07/22/2005 17:50:00 7.6 0.8 9.1 5.7 7.1 0.8 8.8 5.3 88 7 88 305 14.9 0 15.3 14.8 07/22/2005 18:00:00 7.6 0.8 9.5 5.7 7.1 0.8 9.1 4.9 87 7 87 305 15 0.1 15.3 14.8 07/22/2005 18:10:00 6.8 0.8 8.8 4.9 6.4 0.9 8.4 4.2 94 7 87 305 14.1 0.1 14.8 14 07/22/2005 18:20:00 5.3 0.6 6.5 3.8 5 0.5 6.1 2.3 98 4 101 305 14 0 14.5 13.7 07/22/2005 18:30:00 6.6 1.7 10.3 2.3 6.8 1.8 9.9 1.9 52 22 70 305 12.4 1.4 14.8 11 07/22/2005 18:40:00 6.6 1.2 8.8 1.9 7.1 1.1 9.1 2.6 42 15 33 305 10.9 0 11.3 10.8 07/22/2005 18:50:00 5.5 1.5 8.8 2.3 6.2 1.3 8.8 2.3 29 12 24 305 10.6 0 10.8 10.2 07/22/2005 19:00:00 3.5 2 7.2 0.4 4.1 2.1 7.6 0.7 30 33 62 305 10.8 0.3 11.3 10.2 07/22/2005 19:10:00 1.8 0.9 4.6 0.4 2 0.9 4.2 0.4 323 79 3 305 12.2 0.4 12.9 11.3 07/22/2005 19:20:00 1.8 0.9 3.8 0.4 2.2 0.8 4.6 0.7 13 32 33 305 12.2 0.4 12.9 11.6 07/22/2005 19:30:00 1 0.7 2.6 0.4 1.1 0.7 2.6 0.4 171 90 212 305 12.5 0.4 13.2 11.6 07/22/2005 19:40:00 1.5 0.8 3 0.4 1.9 0.7 3.4 0.4 308 72 226 305 12.5 0.8 13.4 10.8 07/22/2005 19:50:00 1.2 0.6 2.6 0.4 1.8 0.6 3.4 0.7 39 16 45 305 10 0.2 10.8 9.7 07/22/2005 20:00:00 0.8 0.6 2.3 0.4 1.4 1 3 0.4 27 17 16 305 9.6 0.5 10.2 8.9 07/22/2005 20:10:00 2.3 1.1 4.9 0.7 3.2 1.2 5.7 1.1 27 9 46 305 8.8 0.3 9.2 8.4 07/22/2005 20:20:00 1.7 1.4 4.6 0.4 2 1.5 5.3 0.4 66 6 51 305 9.7 0.9 11.3 8.4 07/22/2005 20:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 70 0 305 305 12.4 0.5 13.2 11.3 07/22/2005 20:40:00 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 197 47 254 305 12.9 0.2 13.4 12.6 07/22/2005 20:50:00 1.4 0.4 2.6 0.4 1.3 0.4 2.3 0.4 201 15 206 305 12.3 0 12.9 12.1 07/22/2005 21:00:00 1.7 0.4 2.3 0.7 1.5 0.4 2.3 0.4 227 15 242 305 12.6 0 12.9 12.4 07/22/2005 21:10:00 1.8 0.3 2.6 0.7 1.7 0.3 2.3 0.7 218 11 234 305 12.6 0 12.9 12.4 07/22/2005 21:20:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 233 15 268 305 12.4 0.4 12.9 11.6 07/22/2005 21:30:00 1.7 0.3 2.3 1.1 1.7 0.4 2.6 0.7 220 20 214 305 12.2 0.2 12.4 11.6 07/22/2005 21:40:00 1.9 0.3 2.6 1.1 1.7 0.3 2.3 0.7 217 8 213 305 12.2 0.1 12.4 11.8 07/22/2005 21:50:00 0.8 0.5 1.9 0.4 0.7 0.4 1.5 0.4 206 6 231 305 12 0 12.1 11.8 07/22/2005 22:00:00 0.9 0.4 1.9 0.4 0.7 0.3 1.5 0.4 223 11 218 305 11.9 0 12.1 11.8 07/22/2005 22:10:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 296 56 28 305 11.2 0.7 12.1 10.2 07/22/2005 22:20:00 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 28 1 305 305 9.9 0.3 10.2 9.2 07/22/2005 22:30:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 28 1 305 305 9.2 0 9.5 9.2 07/22/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 305 305 9.4 0.1 9.7 9.2 07/22/2005 22:50:00 0.4 0.3 1.9 0.4 0.5 0.3 1.5 0.4 108 51 311 305 10 0 10.2 9.7 07/22/2005 23:00:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 58 79 305 305 10 0.2 10.5 9.7 07/22/2005 23:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 106 1 305 305 11 0.1 11.3 10.5 07/22/2005 23:20:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 119 38 231 305 11.4 0 11.3 11 07/22/2005 23:30:00 0.9 0.3 1.9 0.4 0.8 0.3 1.5 0.4 255 12 256 305 11.2 0.1 11.3 10.5 07/22/2005 23:40:00 0.8 0.5 1.5 0.4 0.7 0.4 1.5 0.4 243 19 254 305 10.2 0 10.8 10 07/22/2005 23:50:00 0.9 0.4 1.5 0.4 0.7 0.3 1.1 0.4 224 1 225 305 10 0 10.2 10 07/23/2005 00:00:00 1 0.4 1.5 0.4 0.9 0.4 1.5 0.4 224 2 223 305 9.9 0 10 9.7 07/23/2005 00:10:00 1.2 0.2 1.5 0.7 1 0.2 1.5 0.4 224 2 224 305 9.7 0 10 9.5 07/23/2005 00:20:00 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 224 2 225 305 9.5 0 9.7 9.5 07/23/2005 00:30:00 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 223 4 223 305 9.6 0 9.7 9.5 07/23/2005 00:40:00 1.3 0.3 1.9 0.7 1.3 0.3 1.9 0.7 197 1 197 305 9.9 0.1 10 9.7 07/23/2005 00:50:00 2 0.3 2.6 1.5 2.1 0.2 2.6 1.5 207 7 211 305 9.7 0 10 9.5 07/23/2005 01:00:00 1.3 0.5 2.3 0.4 1.6 0.3 2.3 1.1 200 7 222 305 9.7 0 9.7 9.5 07/23/2005 01:10:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 199 1 194 305 9.4 0.1 9.7 9.2 07/23/2005 01:20:00 0.6 0.4 1.5 0.4 0.9 0.5 1.9 0.4 199 1 198 305 9.5 0 9.7 9.5 07/23/2005 01:30:00 1.9 0.4 2.6 1.1 2.1 0.2 2.6 1.5 217 13 212 305 9.6 0 9.7 9.5 07/23/2005 01:40:00 2.1 0.2 2.6 1.5 1.9 0.2 2.3 1.5 231 3 233 305 9.5 0 9.7 9.5 07/23/2005 01:50:00 1.9 0.2 2.6 1.5 1.9 0.2 2.3 1.5 218 5 214 305 9.4 0 9.7 9.2 07/23/2005 02:00:00 1.6 0.2 2.3 1.1 1.7 0.2 1.9 1.1 213 11 220 305 9.2 0 9.5 8.9 07/23/2005 02:10:00 1.9 0.3 2.6 1.5 1.7 0.3 2.3 0.7 232 8 225 305 8.9 0 9.2 8.9 07/23/2005 02:20:00 2 0.3 3 1.5 1.6 0.3 2.3 1.1 245 8 245 305 8.9 0 9.2 8.9 07/23/2005 02:30:00 1.9 0.4 2.6 1.1 1.6 0.3 2.3 1.1 237 14 252 305 9.1 0 9.5 8.9 07/23/2005 02:40:00 1.2 0.3 1.9 0.7 1.2 0.3 1.9 0.7 225 23 190 305 9.1 0 9.5 8.9 07/23/2005 02:50:00 1.4 0.4 2.3 0.7 1.1 0.3 1.9 0.4 244 8 253 305 9.1 0 9.2 9.2 07/23/2005 03:00:00 1.2 0.3 1.9 0.7 1 0.3 1.5 0.4 243 5 247 305 9.1 0 9.2 9.2 07/23/2005 03:10:00 1.3 0.5 2.3 0.4 0.8 0.3 1.9 0.4 270 5 269 305 9.2 0 9.2 9.2 07/23/2005 03:20:00 1 0.4 1.9 0.4 1.2 0.5 2.3 0.4 275 1 275 305 9.1 0 9.2 8.9 07/23/2005 03:30:00 1.9 0.2 2.3 1.5 1.5 0.4 2.3 0.7 284 9 275 305 8.8 0 9.2 8.7 07/23/2005 03:40:00 1.3 0.4 1.9 0.4 0.7 0.4 1.5 0.4 298 5 302 305 8.7 0 8.9 8.7 07/23/2005 03:50:00 1.7 0.4 2.3 0.4 1.1 0.5 1.9 0.4 302 4 304 305 8.8 0 8.9 8.7 07/23/2005 04:00:00 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 303 0 303 305 8.8 0 8.9 8.7 07/23/2005 04:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 310 5 305 305 8.8 0 9.2 8.7 07/23/2005 04:20:00 1.2 0.6 2.3 0.4 1.1 0.6 2.3 0.4 320 5 319 305 8.9 0 9.2 8.9 07/23/2005 04:30:00 1.8 0.6 3 0.7 1.9 0.4 2.6 1.1 324 4 320 305 9.1 0 9.2 9.2 07/23/2005 04:40:00 2.1 0.4 3 1.1 2.1 0.4 3 1.5 339 2 337 305 9.1 0 9.2 8.7 07/23/2005 04:50:00 1.1 0.4 2.3 0.4 1 0.4 1.9 0.4 349 7 339 305 8.6 0 8.9 8.4 07/23/2005 05:00:00 0.9 0.3 1.5 0.4 0.9 0.4 1.5 0.4 343 11 349 305 8.8 0 8.9 8.7 07/23/2005 05:10:00 1.7 0.6 2.6 0.4 2 0.6 3 0.4 323 3 325 305 8.2 0.4 8.9 7.7 07/23/2005 05:20:00 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 326 1 305 305 7.8 0.1 8.2 7.7 07/23/2005 05:30:00 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 326 1 305 305 7.6 0 7.9 7.7 07/23/2005 05:40:00 0.5 0.2 1.5 0.4 0.7 0.3 1.5 0.4 355 15 2 305 7.5 0 7.9 7.4 07/23/2005 05:50:00 0.7 0.4 1.9 0.4 0.7 0.4 1.5 0.4 62 35 29 305 7.4 0 7.9 7.4 07/23/2005 06:00:00 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0 15 350 305 7.5 0 7.9 7.4 07/23/2005 06:10:00 1.3 0.4 2.6 0.4 1.3 0.3 1.9 0.4 52 15 79 305 7.8 0.1 8.4 7.4 07/23/2005 06:20:00 1 0.6 2.6 0.4 1 0.5 2.3 0.4 24 23 10 305 8.4 0.1 8.9 8.2 07/23/2005 06:30:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 30 21 48 305 8.2 0.1 8.9 8.2 07/23/2005 06:40:00 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 29 17 73 305 8.2 0.1 8.9 8.2 07/23/2005 06:50:00 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 16 3 15 305 8.6 0.1 9.2 8.4 07/23/2005 07:00:00 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 6 6 14 305 8.6 0 9.2 8.2 07/23/2005 07:10:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 12 4 9 305 8.7 0.2 9.2 8.2 07/23/2005 07:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 32 26 19 305 9.5 0.1 10.2 9.2 07/23/2005 07:30:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 8 39 348 305 9.9 0 10 9.7 07/23/2005 07:40:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 22 16 40 305 9.7 0 10 9.5 07/23/2005 07:50:00 0.8 0.3 1.5 0.4 1 0.3 1.5 0.4 6 3 12 305 9.3 0 9.7 9.2 07/23/2005 08:00:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 6 1 5 305 9.3 0 9.7 9.2 07/23/2005 08:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 6 1 305 305 9.7 0 10 9.5 07/23/2005 08:20:00 1.2 0.8 2.6 0.4 1.1 0.7 2.6 0.4 269 49 243 305 9.7 0.2 10 9.2 07/23/2005 08:30:00 1.9 0.4 3 0.7 1.9 0.4 2.6 0.7 226 9 238 305 8.9 0.1 9.2 8.7 07/23/2005 08:40:00 1.8 0.4 2.6 0.4 1.8 0.4 2.6 0.7 221 8 218 305 8.6 0 8.7 8.4 07/23/2005 08:50:00 1.5 0.5 2.6 0.4 1.6 0.4 2.6 0.7 220 13 218 305 8.7 0 8.9 8.4 07/23/2005 09:00:00 1.6 0.4 2.3 0.7 1.7 0.4 2.6 0.7 219 14 242 305 9.1 0.1 9.2 8.9 07/23/2005 09:10:00 1.8 0.3 2.6 0.7 1.9 0.3 3 0.7 210 10 215 305 9.1 0 9.5 8.9 07/23/2005 09:20:00 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 218 10 218 305 9.3 0 9.5 9.2 07/23/2005 09:30:00 1.8 0.5 3 0.7 1.9 0.5 3 0.7 210 10 210 305 9.4 0 9.7 9.2 07/23/2005 09:40:00 1.5 0.4 2.3 0.4 1.8 0.4 2.6 0.7 206 6 202 305 9.5 0 9.7 9.2 07/23/2005 09:50:00 1.8 0.5 2.6 0.4 1.9 0.4 2.6 1.1 213 10 212 305 9.8 0 10 9.7 07/23/2005 10:00:00 2.2 0.4 3 0.7 2.2 0.4 3 1.1 218 10 211 305 9.9 0 10 9.7 07/23/2005 10:10:00 2.2 0.4 3.4 1.1 2.2 0.4 3.4 1.1 216 10 222 305 9.9 0 10 9.7 07/23/2005 10:20:00 2.5 0.5 3.8 1.5 2.4 0.4 3.4 1.5 235 12 249 305 9.7 0 10 9.5 07/23/2005 10:30:00 2.4 0.6 3.8 0.7 2.2 0.5 3.4 0.7 253 11 263 305 9.3 0.1 9.7 9.2 07/23/2005 10:40:00 1.4 0.6 2.6 0.4 1.2 0.5 2.3 0.4 238 21 267 305 9.4 0.2 10 9.2 07/23/2005 10:50:00 1.7 0.4 3 0.7 1.7 0.4 2.6 0.7 228 12 247 305 9.9 0 10 9.7 07/23/2005 11:00:00 2.1 0.5 3 1.1 2 0.4 3.4 1.1 217 14 201 305 9.7 0 9.7 9.7 07/23/2005 11:10:00 1.2 0.5 2.3 0.4 1.3 0.4 2.3 0.4 212 14 208 305 9.9 0 10 9.7 07/23/2005 11:20:00 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 203 29 238 305 10.6 0.4 11.3 10 07/23/2005 11:30:00 0.8 0.6 2.3 0.4 0.9 0.5 2.3 0.4 233 69 251 305 11.6 0.1 11.8 11 07/23/2005 11:40:00 2.1 0.7 3.8 0.4 2 0.6 3.4 0.7 238 16 220 305 11.4 0.2 11.8 10.8 07/23/2005 11:50:00 1.7 0.5 3 0.7 1.7 0.4 2.6 0.7 232 13 245 305 10.7 0.1 11 10.5 07/23/2005 12:00:00 1.1 0.6 3 0.4 1.3 0.6 3 0.4 294 22 300 305 11.8 0.3 12.4 11 07/23/2005 12:10:00 1.8 0.6 3.4 0.4 2 0.6 3.4 0.7 300 12 298 305 11.6 0.4 12.1 11 07/23/2005 12:20:00 0.8 0.5 2.6 0.4 0.9 0.5 2.3 0.4 282 36 281 305 11 0.1 11.6 10.8 07/23/2005 12:30:00 1.2 0.8 3.4 0.4 1.3 0.8 3 0.4 292 17 275 305 12 0.2 12.4 11.6 07/23/2005 12:40:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 285 20 266 305 11.8 0 12.1 11.6 07/23/2005 12:50:00 1.6 0.8 3 0.4 1.7 0.7 3 0.4 310 17 253 305 12.2 0 12.4 12.1 07/23/2005 13:00:00 1.4 0.7 3.8 0.4 1.5 0.6 3.4 0.4 297 21 298 305 12.1 0 12.4 11.8 07/23/2005 13:10:00 1.8 0.7 3.4 0.4 1.9 0.6 3.8 0.4 299 15 309 305 11.9 0 12.1 11.8 07/23/2005 13:20:00 1 0.6 2.6 0.4 1 0.5 1.9 0.4 285 22 268 305 12.1 0.2 12.6 11.8 07/23/2005 13:30:00 1.5 0.6 3.4 0.4 1.6 0.6 3.8 0.4 296 16 288 305 13 0 13.2 12.6 07/23/2005 13:40:00 1.6 0.6 3 0.4 1.6 0.5 3.4 0.7 293 15 290 305 13 0 13.2 12.9 07/23/2005 13:50:00 1.8 0.6 3 0.4 1.7 0.6 3 0.4 294 13 303 305 12.8 0.1 13.2 12.6 07/23/2005 14:00:00 1.8 0.7 3.4 0.4 1.7 0.6 3.4 0.7 288 13 285 305 12.3 0.1 12.6 11.8 07/23/2005 14:10:00 1.6 0.4 2.6 0.4 1.6 0.5 3 0.4 292 16 310 305 12.2 0 12.4 12.1 07/23/2005 14:20:00 1.8 0.8 3.4 0.4 1.8 0.8 3.4 0.4 300 21 285 305 12.2 0 12.4 12.1 07/23/2005 14:30:00 1.7 0.6 3 0.4 1.7 0.5 3 0.4 292 17 303 305 12.4 0.2 12.9 12.1 07/23/2005 14:40:00 1.8 0.5 3.4 0.7 1.9 0.5 3.8 0.4 295 16 303 305 12.6 0 12.9 12.6 07/23/2005 14:50:00 1.9 0.7 3.8 0.4 1.9 0.7 3.8 0.4 291 20 317 305 12.9 0 13.2 12.6 07/23/2005 15:00:00 1.8 0.7 3.8 0.4 1.8 0.7 3 0.4 296 16 292 305 12.8 0 13.2 12.9 07/23/2005 15:10:00 2.1 0.5 3.8 1.1 2.2 0.6 3.8 0.7 300 16 292 305 12.5 0.1 12.9 12.1 07/23/2005 15:20:00 2 0.8 3.8 0.4 2.2 0.6 3.8 0.7 298 14 306 305 12.5 0 12.9 12.1 07/23/2005 15:30:00 2.7 0.7 5.3 1.1 2.8 0.6 4.6 1.1 309 11 305 305 12.4 0 12.4 12.1 07/23/2005 15:40:00 2.5 0.6 3.8 1.1 2.5 0.6 4.2 1.1 312 12 312 305 11.9 0 12.1 11.6 07/23/2005 15:50:00 2.1 0.6 3.4 0.7 2.2 0.6 3.4 0.7 308 15 320 305 12 0.1 12.1 11.6 07/23/2005 16:00:00 2.6 0.7 4.6 0.4 2.7 0.7 4.2 1.1 303 15 287 305 12 0 12.1 11.8 07/23/2005 16:10:00 2.3 0.5 3.4 1.1 2.3 0.6 3.8 0.7 291 19 296 305 12.1 0 12.4 11.8 07/23/2005 16:20:00 2.2 0.5 3.8 1.1 2.1 0.6 4.2 0.4 292 16 305 305 12.5 0 12.9 12.1 07/23/2005 16:30:00 2.2 0.6 3.8 0.7 2.1 0.6 3.4 0.4 290 18 270 305 12.5 0 12.9 12.1 07/23/2005 16:40:00 2.7 0.7 4.2 1.1 2.5 0.6 3.8 0.7 288 15 274 305 12.1 0.2 12.4 11.6 07/23/2005 16:50:00 2.6 0.6 4.2 0.7 2.5 0.6 4.6 0.7 290 15 302 305 11.8 0 11.8 11.6 07/23/2005 17:00:00 2.6 0.6 3.8 0.7 2.3 0.6 3.4 0.7 277 22 296 305 11.6 0.1 11.8 11.3 07/23/2005 17:10:00 2.5 0.6 3.8 0.7 2.2 0.7 3.8 0.4 279 13 265 305 11.4 0.2 12.1 11 07/23/2005 17:20:00 2.1 0.6 3.8 0.4 1.7 0.5 3 0.4 263 21 279 305 11.4 0 11.6 11 07/23/2005 17:30:00 1.7 0.7 3.4 0.4 1.4 0.7 3.4 0.4 272 23 276 305 11.5 0.1 11.8 11.3 07/23/2005 17:40:00 2.4 0.8 4.2 0.4 2 0.7 3.8 0.7 264 20 290 305 11.7 0.1 11.8 11.3 07/23/2005 17:50:00 2.2 0.7 4.2 0.4 2 0.5 3.4 0.4 261 22 283 305 11.2 0 11.3 11 07/23/2005 18:00:00 1.4 0.6 3 0.4 1.2 0.5 2.3 0.4 271 26 307 305 11.6 0.1 11.8 11.3 07/23/2005 18:10:00 2 0.8 4.6 0.4 1.7 0.7 4.2 0.4 289 23 302 305 12.4 0.1 12.4 11.8 07/23/2005 18:20:00 2.4 0.8 4.2 0.4 2.1 0.6 3.8 0.7 277 20 287 305 11.6 0.3 12.4 11.3 07/23/2005 18:30:00 2.3 0.8 4.2 0.7 2 0.7 3.8 0.4 268 23 254 305 11.1 0 11.3 10.8 07/23/2005 18:40:00 2.2 0.7 4.2 0.4 1.9 0.6 3.8 0.4 271 20 275 305 11 0 11.3 10.8 07/23/2005 18:50:00 1.7 0.6 3 0.4 1.5 0.6 3 0.4 277 24 302 305 11.4 0.1 11.6 11 07/23/2005 19:00:00 1.7 0.6 3.4 0.4 1.6 0.6 3 0.4 270 38 304 305 11.4 0 11.6 11 07/23/2005 19:10:00 1.7 0.8 3.8 0.4 1.5 0.7 3.8 0.4 266 30 305 305 11.2 0 11.6 10.8 07/23/2005 19:20:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 268 38 265 305 11.7 0.1 11.8 11.3 07/23/2005 19:30:00 1.1 0.6 2.6 0.4 0.8 0.5 1.9 0.4 272 53 310 305 11.9 0 11.8 11.3 07/23/2005 19:40:00 1.5 0.7 3 0.4 1.2 0.6 3.4 0.4 281 23 319 305 11.6 0.1 11.8 11.3 07/23/2005 19:50:00 1.5 0.9 3.8 0.4 1.2 0.8 3.8 0.4 257 43 285 305 11.4 0.1 11.8 11 07/23/2005 20:00:00 2 0.9 4.2 0.4 1.6 0.8 3.4 0.4 264 26 280 305 10.8 0.1 11.3 10.5 07/23/2005 20:10:00 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 248 28 265 305 10.5 0 11 10.2 07/23/2005 20:20:00 1.6 0.9 4.2 0.4 1.4 0.8 3.8 0.4 277 47 270 305 10.9 0 11.3 10.5 07/23/2005 20:30:00 1 0.6 3.4 0.4 1 0.6 2.6 0.4 240 76 239 305 11.4 0.3 12.4 11 07/23/2005 20:40:00 1.5 0.6 3.4 0.4 1.2 0.6 3.4 0.4 247 47 256 305 11.8 0.1 12.6 11.3 07/23/2005 20:50:00 1.6 0.8 3.8 0.4 1.4 0.7 3.8 0.4 245 56 242 305 12 0 12.1 11.6 07/23/2005 21:00:00 1.6 1 4.2 0.4 1.6 0.7 3.8 0.4 233 45 258 305 11.9 0 12.1 11.8 07/23/2005 21:10:00 1.5 0.7 3 0.4 1.3 0.5 2.6 0.4 232 45 279 305 12.2 0 12.4 11.8 07/23/2005 21:20:00 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 222 36 255 305 12.4 0 12.4 12.4 07/23/2005 21:30:00 1.5 0.7 3 0.4 1.4 0.6 3 0.4 213 32 213 305 12.3 0 12.4 12.1 07/23/2005 21:40:00 1.9 0.7 3.8 0.4 1.6 0.6 3.4 0.4 229 36 220 305 12.3 0 12.4 12.1 07/23/2005 21:50:00 1.8 0.7 3.4 0.4 1.6 0.7 3 0.4 239 43 238 305 12.3 0 12.9 12.1 07/23/2005 22:00:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 235 51 284 305 12.4 0 12.9 12.1 07/23/2005 22:10:00 1.5 0.6 3.4 0.4 1.3 0.6 3 0.4 231 47 288 305 12.3 0 12.4 12.1 07/23/2005 22:20:00 1.6 0.6 3.4 0.4 1.5 0.5 2.6 0.4 236 30 272 305 12.2 0 12.4 11.8 07/23/2005 22:30:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 214 56 304 305 12 0 12.1 11.8 07/23/2005 22:40:00 1.9 0.6 4.6 0.4 1.7 0.6 3.8 0.4 218 36 208 305 11.8 0 11.8 11.3 07/23/2005 22:50:00 2 0.6 3.4 0.4 1.9 0.5 3 0.4 203 27 221 305 11.4 0 11.8 11.3 07/23/2005 23:00:00 2 0.5 3.4 0.4 2 0.5 3.4 0.4 207 15 186 305 11.4 0 11.3 11.3 07/23/2005 23:10:00 2.2 0.5 3.8 0.7 2.3 0.5 4.2 1.1 202 19 204 305 11.2 0 11.3 11 07/23/2005 23:20:00 2.6 0.6 4.2 1.1 2.4 0.6 4.2 1.1 212 18 221 305 11.2 0 11.3 11 07/23/2005 23:30:00 3.2 0.6 4.9 1.9 3.1 0.6 4.9 1.9 209 16 220 305 11 0 11 11 07/23/2005 23:40:00 3.2 0.6 4.9 1.9 3.1 0.6 4.6 1.9 207 14 230 305 10.9 0 11 10.8 07/23/2005 23:50:00 3.5 0.6 5.3 1.5 3.4 0.5 5.3 1.9 209 21 211 305 10.8 0 11 10.8 07/24/2005 00:00:00 3.3 0.5 5.3 1.5 3.1 0.5 4.2 1.5 214 16 209 305 10.8 0 11 10.8 07/24/2005 00:10:00 3.3 0.6 5.7 0.7 3.1 0.5 4.9 1.1 211 13 231 305 10.8 0 10.8 10.8 07/24/2005 00:20:00 3.3 0.6 5.3 1.5 3.3 0.6 4.9 1.9 211 16 227 305 10.7 0 10.8 10.5 07/24/2005 00:30:00 2.9 0.7 4.9 1.1 2.9 0.7 4.9 1.1 202 18 216 305 10.7 0 10.8 10.5 07/24/2005 00:40:00 3.2 0.5 4.2 1.5 3.1 0.5 4.2 1.1 212 12 226 305 10.7 0 10.8 10.5 07/24/2005 00:50:00 3.5 0.6 5.3 1.9 3.3 0.5 4.6 2.3 204 12 196 305 10.6 0 10.8 10.5 07/24/2005 01:00:00 3.6 0.5 4.9 2.6 3.4 0.5 4.9 2.3 208 9 223 305 10.4 0 10.5 10.2 07/24/2005 01:10:00 3 0.5 4.2 1.9 2.9 0.5 3.8 1.5 213 13 210 305 10.3 0 10.5 10.2 07/24/2005 01:20:00 3.1 0.7 4.9 1.1 2.8 0.7 4.6 1.1 230 17 219 305 10.3 0 10.5 10.2 07/24/2005 01:30:00 3 0.6 4.9 1.5 2.6 0.8 4.9 0.4 239 21 227 305 10 0.1 10.2 9.7 07/24/2005 01:40:00 2.6 0.7 5.3 1.1 2.5 0.6 4.9 0.7 232 23 258 305 9.7 0 9.7 9.5 07/24/2005 01:50:00 2 0.7 3.4 0.4 1.9 0.7 3.4 0.4 221 35 184 305 9.3 0 9.5 9.2 07/24/2005 02:00:00 3 0.5 4.2 1.1 2.8 0.5 3.8 1.5 218 13 224 305 9.1 0 9.5 8.9 07/24/2005 02:10:00 3.1 0.6 4.6 1.9 2.9 0.5 4.2 1.9 215 11 214 305 9.1 0 9.2 8.9 07/24/2005 02:20:00 3.4 0.5 4.6 1.9 3.2 0.5 4.6 1.9 221 9 219 305 8.9 0 9.2 8.9 07/24/2005 02:30:00 3.4 0.5 4.6 2.3 3.3 0.4 4.6 2.3 221 10 224 305 8.9 0 8.9 8.9 07/24/2005 02:40:00 3 0.5 4.2 1.5 2.9 0.5 4.2 1.5 221 10 229 305 8.8 0 8.9 8.9 07/24/2005 02:50:00 3.2 0.4 4.6 1.9 3 0.4 3.8 1.9 229 9 217 305 8.8 0 8.9 8.7 07/24/2005 03:00:00 3 0.5 4.2 1.5 2.8 0.5 4.2 1.1 222 12 242 305 8.8 0 8.9 8.7 07/24/2005 03:10:00 2.8 0.5 4.2 1.5 2.7 0.4 4.2 1.5 214 11 201 305 8.8 0 8.9 8.9 07/24/2005 03:20:00 3.4 0.6 4.9 1.9 3.4 0.5 4.9 2.3 206 10 213 305 8.8 0 8.9 8.9 07/24/2005 03:30:00 3.1 0.5 4.6 2.3 3.1 0.5 4.6 1.9 200 12 201 305 8.9 0 9.2 8.9 07/24/2005 03:40:00 3.7 0.6 5.3 1.9 3.6 0.6 4.9 1.9 205 9 207 305 8.9 0 9.2 8.9 07/24/2005 03:50:00 3.6 0.5 4.6 2.3 3.6 0.5 4.9 2.6 209 10 208 305 8.9 0 9.2 8.9 07/24/2005 04:00:00 3.6 0.4 4.9 2.6 3.5 0.5 4.9 2.3 210 10 213 305 8.9 0 9.2 8.9 07/24/2005 04:10:00 3.2 0.6 4.9 1.9 3.1 0.6 4.6 1.5 216 11 217 305 9 0 9.2 8.9 07/24/2005 04:20:00 2.7 0.7 4.2 1.1 2.6 0.7 3.8 1.1 226 13 219 305 9 0 9.2 8.9 07/24/2005 04:30:00 2.1 0.8 4.2 0.4 1.8 0.7 3.8 0.4 237 22 237 305 8.9 0 9.2 8.9 07/24/2005 04:40:00 2.1 0.5 3.4 0.4 1.8 0.5 3 0.7 251 24 217 305 8.9 0 8.9 8.9 07/24/2005 04:50:00 1.9 0.7 4.2 0.4 1.6 0.6 3 0.4 254 23 293 305 8.8 0 8.9 8.7 07/24/2005 05:00:00 2.2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 252 24 264 305 8.8 0 8.9 8.7 07/24/2005 05:10:00 2.5 0.5 3.8 1.5 2.1 0.5 3.8 1.1 257 11 251 305 8.7 0 8.9 8.7 07/24/2005 05:20:00 2.9 0.6 4.2 1.5 2.7 0.6 4.2 1.1 260 13 236 305 8.6 0 8.7 8.4 07/24/2005 05:30:00 2.8 0.6 4.6 1.1 2.5 0.6 3.8 0.4 246 15 259 305 8.6 0 8.7 8.4 07/24/2005 05:40:00 2.9 0.6 4.6 1.1 2.6 0.5 4.2 1.5 232 16 245 305 8.6 0 8.7 8.4 07/24/2005 05:50:00 2.8 0.6 4.2 1.1 2.6 0.6 4.2 1.5 227 17 247 305 8.6 0 8.7 8.4 07/24/2005 06:00:00 2.4 0.7 4.6 0.7 2.4 0.6 4.2 1.1 221 21 256 305 8.7 0 8.9 8.7 07/24/2005 06:10:00 2.5 0.6 3.4 0.4 2.3 0.6 3.4 0.7 230 22 224 305 8.7 0 8.9 8.7 07/24/2005 06:20:00 1.8 0.7 4.2 0.4 1.4 0.6 3 0.4 259 22 279 305 8.6 0 8.9 8.4 07/24/2005 06:30:00 1.2 0.7 3.4 0.4 1.2 0.6 3 0.4 221 49 195 305 8.6 0 8.9 8.4 07/24/2005 06:40:00 1.1 0.8 3.8 0.4 1 0.7 3 0.4 279 69 348 305 8.7 0 8.9 8.7 07/24/2005 06:50:00 1.4 0.7 3.4 0.4 1.2 0.5 2.6 0.4 245 43 300 305 8.8 0 8.9 8.7 07/24/2005 07:00:00 1 0.7 3 0.4 0.8 0.5 2.3 0.4 243 56 296 305 8.9 0 9.2 8.9 07/24/2005 07:10:00 1.3 0.9 3.4 0.4 1 0.7 2.6 0.4 279 36 275 305 8.9 0 9.2 8.9 07/24/2005 07:20:00 0.7 0.5 2.3 0.4 0.5 0.3 1.9 0.4 251 53 292 305 9.1 0 9.2 8.9 07/24/2005 07:30:00 1.1 0.6 3 0.4 1.1 0.6 2.6 0.4 230 49 220 305 9 0 9.2 8.9 07/24/2005 07:40:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 237 61 177 305 9.2 0 9.2 9.2 07/24/2005 07:50:00 0.7 0.5 2.6 0.4 0.7 0.5 2.3 0.4 261 41 293 305 9.2 0 9.5 9.2 07/24/2005 08:00:00 1.1 0.5 2.6 0.4 1.1 0.5 2.3 0.4 254 45 298 305 9.3 0 9.5 9.2 07/24/2005 08:10:00 1.2 0.5 2.6 0.4 1 0.5 2.3 0.4 301 28 324 305 9.3 0 9.5 9.2 07/24/2005 08:20:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 283 38 272 305 9.3 0 9.5 9.2 07/24/2005 08:30:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 239 27 213 305 9.5 0 9.7 9.2 07/24/2005 08:40:00 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 215 33 215 305 9.9 0 10.2 9.7 07/24/2005 08:50:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 263 61 324 305 10 0 10.2 10 07/24/2005 09:00:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 311 47 281 305 10.2 0 10.5 10 07/24/2005 09:10:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 279 28 299 305 10.2 0 10.5 10.2 07/24/2005 09:20:00 0.9 0.5 2.3 0.4 0.8 0.5 2.6 0.4 273 36 250 305 10.3 0 10.5 10.2 07/24/2005 09:30:00 1.2 0.6 2.6 0.4 1.2 0.6 3 0.4 306 16 289 305 10.4 0 10.5 10.2 07/24/2005 09:40:00 1.8 0.5 3 0.4 1.6 0.5 3.4 0.4 292 13 310 305 10.3 0 10.5 10.2 07/24/2005 09:50:00 1.4 0.7 3 0.4 1.4 0.7 3 0.4 283 33 296 305 10.2 0 10.2 10.2 07/24/2005 10:00:00 1.2 0.6 2.6 0.4 1.1 0.5 2.3 0.4 288 47 283 305 10.2 0 10.2 10 07/24/2005 10:10:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 283 27 302 305 10.3 0 10.5 10.2 07/24/2005 10:20:00 1.2 0.5 2.6 0.4 1.1 0.5 2.3 0.4 275 23 278 305 10.6 0 10.8 10.5 07/24/2005 10:30:00 1 0.7 2.6 0.4 1.1 0.7 3 0.4 345 38 336 305 10.9 0 11 10.8 07/24/2005 10:40:00 1.3 0.5 2.6 0.4 1.4 0.4 2.6 0.4 299 32 279 305 11.3 0 11.3 11 07/24/2005 10:50:00 1.4 0.8 3.4 0.4 1.4 0.7 3.4 0.4 306 26 326 305 11.3 0.1 11.6 11 07/24/2005 11:00:00 1.7 0.6 3 0.4 1.8 0.6 3.4 0.4 301 17 304 305 11.3 0 11.6 11 07/24/2005 11:10:00 1.5 0.6 3 0.4 1.7 0.6 3.4 0.4 291 17 281 305 11.6 0 11.8 11.3 07/24/2005 11:20:00 1.7 0.7 3.4 0.4 1.8 0.7 3.4 0.4 303 15 276 305 12.2 0 12.4 11.8 07/24/2005 11:30:00 2 0.4 3 1.1 2 0.5 3.4 0.7 294 15 281 305 12 0 12.1 11.8 07/24/2005 11:40:00 1.6 0.6 2.6 0.4 1.7 0.6 3 0.4 294 15 308 305 12.4 0.1 12.4 12.1 07/24/2005 11:50:00 1.9 0.5 3.4 0.4 1.9 0.5 3 0.7 289 15 296 305 12.3 0 12.4 12.1 07/24/2005 12:00:00 1.7 0.5 2.6 0.4 1.7 0.5 3.4 0.4 287 15 300 305 12 0 12.4 11.8 07/24/2005 12:10:00 2 0.4 3.4 1.1 1.9 0.5 3.4 0.7 291 12 297 305 12.2 0 12.4 12.1 07/24/2005 12:20:00 2.1 0.5 3.4 0.7 2.1 0.5 3.4 1.1 290 12 266 305 12.3 0 12.4 12.1 07/24/2005 12:30:00 2.3 0.5 3.4 0.7 2.4 0.5 3.8 1.1 294 11 278 305 12.2 0.1 12.4 11.8 07/24/2005 12:40:00 2.6 0.4 3.8 1.5 2.6 0.4 3.8 1.5 303 9 300 305 11.6 0.2 12.1 11.3 07/24/2005 12:50:00 2.1 0.6 3.4 0.4 2.3 0.5 3.8 0.7 304 13 313 305 11.2 0.1 11.3 11 07/24/2005 13:00:00 2.5 0.5 3.8 1.1 2.6 0.6 4.6 1.1 307 12 305 305 11.4 0 11.3 11.3 07/24/2005 13:10:00 2.3 0.6 3.8 0.7 2.4 0.6 3.8 1.1 305 12 305 305 11.4 0 11.6 11 07/24/2005 13:20:00 2.2 0.5 3.4 0.7 2.3 0.6 3.8 0.7 311 12 305 305 11.4 0 11.6 11.3 07/24/2005 13:30:00 2.1 0.7 3.8 0.4 2.3 0.6 3.8 0.4 318 21 333 305 11.2 0.1 11.6 10.8 07/24/2005 13:40:00 1.7 0.7 3.8 0.4 1.8 0.7 3.8 0.4 316 21 326 305 10.8 0 11 10.8 07/24/2005 13:50:00 1.8 0.7 4.2 0.4 2 0.6 4.2 0.4 316 26 291 305 11 0 11.3 10.8 07/24/2005 14:00:00 2.3 1 4.9 0.4 2.3 1 5.3 0.4 304 20 203 305 11.5 0.1 11.8 11 07/24/2005 14:10:00 2.8 0.8 4.6 0.7 2.8 0.7 4.2 1.1 304 12 286 305 11.5 0.1 11.8 11 07/24/2005 14:20:00 2.3 0.8 4.6 0.7 2.3 0.8 3.8 0.4 302 13 292 305 10.8 0 11 10.8 07/24/2005 14:30:00 2.1 0.6 3.8 0.4 2.2 0.5 3.4 1.1 299 17 276 305 11 0.2 11.6 10.8 07/24/2005 14:40:00 2.3 0.8 4.2 0.4 2.2 0.7 3.8 0.4 293 20 269 305 11.7 0 11.8 11.3 07/24/2005 14:50:00 2.1 0.5 3.4 0.7 2 0.6 3.4 0.4 267 32 314 305 11.5 0 11.8 11.3 07/24/2005 15:00:00 2.2 0.6 3.8 0.4 2.1 0.6 3.8 0.4 231 22 235 305 11.2 0 11.3 11 07/24/2005 15:10:00 2.6 0.9 4.9 0.7 2.5 0.8 4.6 0.4 269 27 238 305 11.4 0 11.6 11.3 07/24/2005 15:20:00 2.5 1 4.9 0.7 2.2 0.9 4.6 0.4 275 22 282 305 11.4 0 11.6 11.3 07/24/2005 15:30:00 2.7 0.7 4.9 0.7 2.4 0.6 4.2 1.1 281 19 294 305 10.9 0 11.3 10.5 07/24/2005 15:40:00 2.1 0.8 4.2 0.4 2 0.8 3.8 0.4 301 22 319 305 10.5 0.2 10.8 10.2 07/24/2005 15:50:00 1.3 0.7 3 0.4 1.3 0.7 3 0.4 322 23 330 305 10.3 0 10.2 10.2 07/24/2005 16:00:00 1.4 1 3.4 0.4 1.3 0.9 3.4 0.4 308 47 283 305 10.2 0 10.2 10 07/24/2005 16:10:00 1.5 0.7 3.8 0.4 1.4 0.6 3.4 0.4 296 27 293 305 10.2 0.1 10.5 10 07/24/2005 16:20:00 1.9 0.8 3.8 0.4 1.8 0.8 3.8 0.4 286 26 281 305 10.3 0 10.5 10.2 07/24/2005 16:30:00 1.7 0.7 3.4 0.4 1.6 0.6 3 0.4 294 22 296 305 10.3 0 10.5 10.2 07/24/2005 16:40:00 2.3 0.7 4.2 0.7 1.9 0.8 3.8 0.4 291 27 296 305 10.1 0 10.2 10 07/24/2005 16:50:00 1.3 0.6 2.6 0.4 1.3 0.5 2.6 0.4 285 35 348 305 10.3 0 10.5 10.2 07/24/2005 17:00:00 1.4 0.7 3.4 0.4 1.2 0.6 2.6 0.4 294 24 319 305 10.4 0 10.8 10.2 07/24/2005 17:10:00 1.5 0.8 3.8 0.4 1.3 0.7 3.4 0.4 286 24 324 305 10.8 0.1 11 10.5 07/24/2005 17:20:00 1.9 0.7 3.8 0.4 1.8 0.7 4.2 0.4 288 23 330 305 11 0 11.3 10.8 07/24/2005 17:30:00 2.3 0.9 4.6 0.4 2.3 0.8 4.2 0.4 314 20 275 305 11 0 11.3 10.8 07/24/2005 17:40:00 2.1 0.9 4.2 0.4 2.2 0.9 3.8 0.4 315 23 308 305 10.8 0 10.8 10.5 07/24/2005 17:50:00 0.9 0.7 3 0.4 1.1 0.8 3 0.4 1 56 293 305 11 0.1 11.3 10.8 07/24/2005 18:00:00 1.4 0.9 3.8 0.4 1.5 0.8 3.8 0.4 330 51 276 305 11.1 0 11.3 11 07/24/2005 18:10:00 1.7 0.7 3.8 0.4 1.6 0.6 3 0.4 300 29 272 305 11 0 11.3 10.8 07/24/2005 18:20:00 2.2 0.8 4.2 0.4 2 0.7 3.8 0.7 307 22 312 305 11.5 0.1 11.8 11.3 07/24/2005 18:30:00 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 342 58 325 305 11.5 0 11.8 11.3 07/24/2005 18:40:00 1.5 0.8 4.2 0.4 1.4 0.7 3.4 0.4 288 26 302 305 12 0 12.4 11.6 07/24/2005 18:50:00 1.9 0.7 3.8 0.4 1.8 0.7 3.8 0.4 293 33 307 305 12 0 12.4 11.8 07/24/2005 19:00:00 2.6 0.8 4.9 0.4 2.3 0.8 5.3 0.4 278 18 287 305 11.9 0 12.4 11.6 07/24/2005 19:10:00 2.1 0.7 3.8 0.4 2 0.7 3.8 0.4 275 24 262 305 12 0 12.1 11.8 07/24/2005 19:20:00 2.7 0.8 4.9 0.7 2.5 0.8 5.3 0.4 282 21 293 305 11.8 0.2 12.1 11.3 07/24/2005 19:30:00 2.2 1 4.6 0.4 2.3 0.8 4.6 0.7 287 24 305 305 11.4 0 11.8 11.3 07/24/2005 19:40:00 1.9 0.7 3.8 0.4 1.8 0.7 3.8 0.4 294 21 318 305 12 0 12.1 11.6 07/24/2005 19:50:00 2 0.6 3.4 0.7 1.8 0.6 3.8 0.7 284 19 288 305 11.8 0.2 12.1 11.3 07/24/2005 20:00:00 1.4 0.8 3.4 0.4 1.3 0.8 3.8 0.4 283 22 310 305 11.2 0 11.3 11 07/24/2005 20:10:00 2.1 0.8 4.2 0.4 1.9 0.7 3 0.4 300 26 306 305 11.2 0.1 11.3 10.8 07/24/2005 20:20:00 1.3 0.8 3.8 0.4 1.2 0.6 2.6 0.4 285 35 270 305 10.9 0 11.3 10.8 07/24/2005 20:30:00 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 292 58 233 305 11.3 0.3 11.8 10.8 07/24/2005 20:40:00 1.4 0.9 3.8 0.4 1.2 0.7 3.4 0.4 297 36 278 305 11.2 0.3 11.8 10.5 07/24/2005 20:50:00 1.3 0.6 3 0.4 1.2 0.6 2.6 0.4 275 39 273 305 10.4 0.1 10.5 9.7 07/24/2005 21:00:00 1.3 0.7 3 0.4 1.2 0.6 3 0.4 269 32 297 305 10.2 0 10.2 10 07/24/2005 21:10:00 1.3 0.5 3 0.4 1.1 0.5 2.3 0.4 252 41 259 305 10 0 10.2 10 07/24/2005 21:20:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 260 36 295 305 10 0 10.2 10 07/24/2005 21:30:00 0.8 0.6 3.4 0.4 0.8 0.6 2.6 0.4 260 45 306 305 9.9 0 10 9.7 07/24/2005 21:40:00 1.2 0.5 3 0.4 1.2 0.6 2.6 0.4 276 29 329 305 9.8 0 10 9.7 07/24/2005 21:50:00 1.4 0.6 3 0.4 1.3 0.6 3 0.4 268 23 269 305 9.9 0 10 9.7 07/24/2005 22:00:00 1.7 0.9 3.8 0.4 1.2 0.8 3.4 0.4 264 22 241 305 10.2 0.1 10.5 10 07/24/2005 22:10:00 1.6 0.6 3 0.4 1.3 0.5 2.3 0.4 248 32 251 305 10.1 0.1 10.5 10 07/24/2005 22:20:00 1.5 0.6 3 0.4 1.5 0.5 3 0.4 239 23 252 305 9.8 0 10 9.7 07/24/2005 22:30:00 1.7 0.5 3.8 0.7 1.5 0.5 2.6 0.4 238 22 257 305 9.6 0 9.7 9.5 07/24/2005 22:40:00 1.6 0.6 3.4 0.4 1.4 0.6 2.6 0.4 217 20 208 305 9.6 0 9.7 9.5 07/24/2005 22:50:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 217 22 234 305 9.5 0 9.7 9.5 07/24/2005 23:00:00 1.4 0.6 3 0.4 1.2 0.6 3.4 0.4 227 22 265 305 9.5 0 9.7 9.5 07/24/2005 23:10:00 1.9 0.5 3.4 0.4 1.8 0.5 3 0.4 218 22 215 305 9.4 0 9.5 9.2 07/24/2005 23:20:00 2 0.6 3.8 0.7 1.9 0.5 3 0.7 228 16 223 305 9.3 0 9.5 9.2 07/24/2005 23:30:00 1.7 0.5 2.6 0.7 1.6 0.4 2.6 0.7 217 14 204 305 9.2 0 9.5 9.2 07/24/2005 23:40:00 1.9 0.5 3 0.7 1.7 0.5 3 0.4 222 13 212 305 9.2 0 9.2 9.2 07/24/2005 23:50:00 2.2 0.4 3 1.5 2 0.4 3 0.7 221 9 214 305 9.2 0 9.2 9.2 07/25/2005 00:00:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 216 10 217 305 9.1 0 9.5 9.2 07/25/2005 00:10:00 2.1 0.4 3 0.4 1.9 0.4 3 0.4 216 12 217 305 9.1 0 9.2 8.9 07/25/2005 00:20:00 2 0.4 3 0.7 1.9 0.4 2.6 0.7 220 13 235 305 9.1 0 9.2 8.9 07/25/2005 00:30:00 1.8 0.5 3 0.4 1.7 0.5 3 0.7 220 15 203 305 9 0 9.2 8.9 07/25/2005 00:40:00 1.8 0.5 3 0.4 1.6 0.5 2.6 0.4 215 22 208 305 8.9 0 9.2 8.9 07/25/2005 00:50:00 1.5 0.7 3 0.4 1.4 0.6 3.4 0.4 220 22 234 305 8.9 0 9.2 8.9 07/25/2005 01:00:00 1.4 0.6 2.6 0.4 1.3 0.5 2.3 0.4 202 19 203 305 8.9 0 9.2 8.9 07/25/2005 01:10:00 1.6 0.7 3 0.4 1.4 0.7 2.6 0.4 227 29 205 305 8.9 0 9.2 8.9 07/25/2005 01:20:00 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 219 16 221 305 8.9 0 9.2 8.9 07/25/2005 01:30:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 224 22 217 305 8.9 0 8.9 8.9 07/25/2005 01:40:00 1.8 0.6 2.6 0.4 1.7 0.5 3 0.4 210 17 206 305 8.9 0 8.9 8.9 07/25/2005 01:50:00 2 0.5 3 0.4 1.8 0.6 3.4 0.4 214 20 227 305 8.9 0 9.2 8.9 07/25/2005 02:00:00 2 0.4 3.4 1.1 1.8 0.4 2.6 0.7 219 19 261 305 8.9 0 9.2 8.9 07/25/2005 02:10:00 1.9 0.5 3 0.4 1.7 0.5 2.6 0.4 226 15 214 305 8.9 0 9.2 8.9 07/25/2005 02:20:00 1.9 0.6 3 0.4 1.7 0.5 3 0.4 215 21 208 305 8.9 0 9.2 8.9 07/25/2005 02:30:00 2.1 0.5 3.4 1.1 1.8 0.5 3 0.7 238 16 244 305 8.9 0 9.2 8.9 07/25/2005 02:40:00 2.6 0.7 4.2 1.1 2.3 0.7 4.2 0.7 263 15 270 305 8.8 0 8.9 8.7 07/25/2005 02:50:00 2.3 0.5 3.4 1.1 1.8 0.6 3.4 0.4 258 16 267 305 8.7 0 8.9 8.7 07/25/2005 03:00:00 3.5 0.6 4.9 1.9 2.9 0.6 4.6 1.9 275 10 277 305 8.5 0 8.9 8.2 07/25/2005 03:10:00 2.2 0.6 3.8 0.4 1.7 0.6 3.4 0.4 266 15 261 305 8.2 0 8.4 8.2 07/25/2005 03:20:00 2.4 0.5 3.4 1.5 2 0.5 3 0.7 253 8 242 305 8.2 0 8.2 8.2 07/25/2005 03:30:00 1.6 0.4 2.6 0.7 1.3 0.4 2.6 0.4 239 10 240 305 8.1 0 8.2 8.2 07/25/2005 03:40:00 2.2 0.6 3.4 0.7 1.9 0.7 3 0.4 252 10 248 305 8.2 0 8.2 8.2 07/25/2005 03:50:00 2.5 0.4 4.2 1.5 2.2 0.5 4.2 0.7 248 10 261 305 8.2 0 8.2 8.2 07/25/2005 04:00:00 3 0.5 4.2 1.9 2.5 0.5 3.8 0.7 257 9 259 305 8.2 0 8.2 8.2 07/25/2005 04:10:00 2.6 0.5 3.8 1.1 2.1 0.5 3.4 1.1 259 12 250 305 8.2 0 8.4 8.2 07/25/2005 04:20:00 2.6 0.5 3.8 1.1 2.2 0.5 3.4 1.1 255 9 263 305 8.2 0 8.2 8.2 07/25/2005 04:30:00 2.7 0.5 3.8 1.1 2.3 0.6 3.4 0.7 255 8 251 305 8.2 0 8.4 8.2 07/25/2005 04:40:00 2.2 0.5 3.8 1.1 1.9 0.5 3.4 0.7 252 15 234 305 8.2 0 8.4 8.2 07/25/2005 04:50:00 2.7 0.5 3.8 1.5 2.4 0.5 3.4 1.5 247 9 234 305 8.2 0 8.4 8.2 07/25/2005 05:00:00 2.8 0.3 4.2 1.9 2.6 0.4 4.2 1.5 248 8 255 305 8.3 0 8.4 8.2 07/25/2005 05:10:00 3.5 0.6 4.9 2.3 3.2 0.5 4.6 2.3 246 9 250 305 8.3 0 8.4 8.2 07/25/2005 05:20:00 3.4 0.6 4.6 1.9 3.1 0.6 4.2 1.5 252 6 259 305 8.2 0 8.4 8.2 07/25/2005 05:30:00 3.1 0.4 4.2 1.9 2.8 0.4 3.8 1.5 246 8 242 305 8.2 0 8.4 8.2 07/25/2005 05:40:00 3.2 0.5 4.6 1.9 2.9 0.5 4.2 1.5 249 11 251 305 8.3 0 8.4 8.2 07/25/2005 05:50:00 3.4 0.5 4.6 2.3 3 0.5 4.2 1.5 242 8 243 305 8.2 0 8.4 8.2 07/25/2005 06:00:00 3.3 0.5 4.2 2.3 3 0.4 4.2 1.9 239 12 233 305 8.3 0 8.4 8.2 07/25/2005 06:10:00 3.4 0.5 4.9 2.3 3.1 0.5 4.6 2.3 248 8 241 305 8.2 0 8.4 8.2 07/25/2005 06:20:00 3.7 0.4 4.6 2.6 3.4 0.4 4.6 2.6 250 6 244 305 8.1 0 8.2 7.9 07/25/2005 06:30:00 3.9 0.6 5.3 2.3 3.5 0.6 4.9 1.9 252 8 254 305 8 0 8.2 7.7 07/25/2005 06:40:00 2.9 0.6 4.2 1.9 2.6 0.5 3.8 1.1 246 9 243 305 7.9 0 7.9 7.9 07/25/2005 06:50:00 2.4 0.4 3.4 1.1 2.2 0.5 3.4 1.1 242 9 238 305 7.9 0 7.9 7.7 07/25/2005 07:00:00 2.3 0.5 3.8 1.5 2 0.5 3.4 1.1 248 7 246 305 8 0 8.2 7.9 07/25/2005 07:10:00 2.6 0.6 4.2 1.5 2.4 0.5 3.4 1.1 240 12 256 305 8 0 8.2 7.9 07/25/2005 07:20:00 2.4 0.6 4.2 1.1 2.2 0.5 3.8 1.1 246 11 262 305 8.1 0 8.2 7.9 07/25/2005 07:30:00 2.5 0.5 3.8 1.5 2.4 0.4 3.8 1.5 236 7 227 305 8.1 0 8.2 7.9 07/25/2005 07:40:00 2.9 0.4 4.2 1.9 2.7 0.4 3.8 1.9 234 8 232 305 8.2 0 8.2 8.2 07/25/2005 07:50:00 3.2 0.5 4.6 2.3 3 0.5 4.6 1.9 237 9 251 305 8.2 0 8.2 8.2 07/25/2005 08:00:00 3.4 0.5 4.6 2.3 3.1 0.5 4.9 1.9 244 10 245 305 8.2 0 8.2 8.2 07/25/2005 08:10:00 3.3 0.4 4.6 1.9 2.9 0.5 3.8 1.9 249 7 251 305 8.2 0 8.2 8.2 07/25/2005 08:20:00 3.5 0.5 4.6 2.3 3.1 0.6 4.6 1.5 249 8 262 305 8.2 0 8.4 8.2 07/25/2005 08:30:00 2.9 0.5 4.2 1.5 2.6 0.5 3.8 1.5 243 8 262 305 8.3 0 8.4 8.2 07/25/2005 08:40:00 2.6 0.5 4.2 1.1 2.3 0.6 3.8 1.1 242 9 238 305 8.4 0 8.4 8.2 07/25/2005 08:50:00 3.4 0.4 4.6 2.3 3.1 0.5 4.2 1.9 242 7 243 305 8.4 0 8.4 8.2 07/25/2005 09:00:00 2.8 0.5 3.8 1.5 2.5 0.5 3.8 1.1 239 11 242 305 8.4 0 8.4 8.2 07/25/2005 09:10:00 2.5 0.6 4.2 1.1 2.3 0.6 3.8 1.1 237 9 242 305 8.6 0 8.7 8.4 07/25/2005 09:20:00 2.6 0.3 3.4 1.9 2.4 0.3 3 1.9 242 9 238 305 8.7 0 8.9 8.4 07/25/2005 09:30:00 1.9 0.6 2.6 0.4 1.7 0.6 2.6 0.4 236 11 235 305 8.6 0 8.7 8.4 07/25/2005 09:40:00 2.6 0.4 3.4 1.5 2.5 0.4 3.4 1.5 229 8 232 305 8.8 0 8.9 8.7 07/25/2005 09:50:00 2.8 0.4 3.8 1.5 2.7 0.4 3.8 1.5 233 8 233 305 8.8 0 9.2 8.9 07/25/2005 10:00:00 2.9 0.3 3.4 1.9 2.8 0.4 3.4 1.9 231 8 217 305 8.9 0 9.2 8.9 07/25/2005 10:10:00 2.8 0.3 3.4 1.9 2.8 0.4 3.4 1.9 229 6 231 305 8.9 0 9.2 8.9 07/25/2005 10:20:00 2.5 0.3 3.4 1.9 2.4 0.3 3 1.5 223 8 231 305 9 0 9.2 8.9 07/25/2005 10:30:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 229 7 224 305 9.1 0 9.2 8.9 07/25/2005 10:40:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 229 7 235 305 9.1 0 9.2 8.9 07/25/2005 10:50:00 2.8 0.4 3.8 1.9 2.6 0.4 3.4 1.5 232 8 224 305 9.1 0 9.2 9.2 07/25/2005 11:00:00 2.2 0.5 3.4 0.7 2.1 0.5 3 0.7 239 9 246 305 9.1 0 9.2 8.9 07/25/2005 11:10:00 1.7 0.5 3 0.4 1.7 0.5 3 0.7 229 15 234 305 9.1 0 9.2 8.9 07/25/2005 11:20:00 1.9 0.4 3.4 0.7 1.9 0.5 3 0.4 239 12 247 305 9.2 0 9.2 9.2 07/25/2005 11:30:00 2.5 0.3 3.4 1.9 2.4 0.4 3.4 1.5 237 10 250 305 9.1 0 9.2 8.9 07/25/2005 11:40:00 2.7 0.5 3.8 1.5 2.6 0.4 3.8 1.9 228 9 221 305 9.1 0 9.2 8.9 07/25/2005 11:50:00 3 0.5 4.2 1.5 2.7 0.5 3.8 1.5 226 9 238 305 9 0 9.2 8.9 07/25/2005 12:00:00 3.4 0.5 4.6 2.3 3.1 0.5 4.6 2.3 226 8 231 305 9 0 9.2 8.9 07/25/2005 12:10:00 3.1 0.5 4.2 1.5 2.9 0.5 4.2 1.5 223 11 232 305 8.9 0 9.2 8.9 07/25/2005 12:20:00 3.4 0.5 4.6 2.3 3.3 0.5 4.6 1.9 220 9 218 305 8.9 0 9.2 8.9 07/25/2005 12:30:00 3.2 0.5 4.2 2.3 3 0.4 4.2 1.9 225 9 236 305 9 0 9.2 8.9 07/25/2005 12:40:00 3 0.5 4.2 1.5 2.9 0.4 4.2 1.5 218 10 234 305 8.9 0 9.2 8.9 07/25/2005 12:50:00 2.9 0.5 4.9 1.5 2.8 0.5 4.2 1.5 218 12 227 305 9.1 0 9.5 8.9 07/25/2005 13:00:00 3.4 0.5 4.6 2.3 3.2 0.5 4.6 1.9 218 9 224 305 9.4 0 9.7 9.2 07/25/2005 13:10:00 3.3 0.5 4.9 1.9 3.2 0.5 4.6 1.9 218 10 225 305 9.6 0 9.7 9.5 07/25/2005 13:20:00 3 0.6 4.6 1.9 2.9 0.6 4.2 1.5 225 13 239 305 9.7 0 9.7 9.5 07/25/2005 13:30:00 3 0.5 4.2 1.5 2.9 0.5 4.2 1.5 225 13 217 305 9.7 0 9.7 9.5 07/25/2005 13:40:00 2.8 0.7 4.6 1.1 2.6 0.6 4.6 1.1 245 18 259 305 9.7 0 10 9.7 07/25/2005 13:50:00 2.7 0.5 3.8 1.1 2.4 0.6 4.2 0.7 255 19 269 305 9.8 0 10 9.7 07/25/2005 14:00:00 2.5 0.8 4.6 1.1 2.1 0.7 3.8 0.4 266 20 277 305 10 0 10.2 9.7 07/25/2005 14:10:00 2.6 0.7 4.2 0.7 2.2 0.8 4.2 0.4 253 17 259 305 9.9 0 10 9.7 07/25/2005 14:20:00 3 0.5 4.6 1.1 2.6 0.5 3.8 1.1 258 12 269 305 9.9 0 10 9.7 07/25/2005 14:30:00 2.8 0.5 4.2 1.5 2.4 0.5 3.8 1.1 266 12 264 305 9.7 0 9.7 9.5 07/25/2005 14:40:00 2.6 0.6 3.8 1.1 2.3 0.6 3.8 1.1 272 15 286 305 9.7 0 10 9.5 07/25/2005 14:50:00 2.4 0.5 3.4 1.1 2.3 0.5 3.8 1.1 283 13 272 305 9.7 0 10 9.7 07/25/2005 15:00:00 2.7 0.6 4.2 1.1 2.5 0.7 4.2 1.1 284 13 316 305 9.7 0 10 9.7 07/25/2005 15:10:00 2.5 0.4 3.8 0.7 2.4 0.5 3.4 1.1 292 13 280 305 10 0 10.2 10 07/25/2005 15:20:00 2.4 0.7 4.6 0.4 2.4 0.7 4.2 0.7 297 12 298 305 10.2 0 10.2 10 07/25/2005 15:30:00 2.8 0.6 4.2 1.1 2.6 0.6 3.8 1.1 291 13 298 305 10.2 0 10.5 10.2 07/25/2005 15:40:00 2.9 0.5 4.2 1.5 2.5 0.6 4.2 1.1 283 15 278 305 10.2 0 10.2 10 07/25/2005 15:50:00 3.3 0.4 4.6 2.3 3.1 0.4 4.2 1.9 286 12 287 305 10 0 10.2 9.7 07/25/2005 16:00:00 3.4 0.5 4.6 2.3 3 0.5 4.6 1.9 287 11 277 305 9.9 0 10.2 9.7 07/25/2005 16:10:00 3 0.4 4.2 1.9 2.7 0.6 4.2 1.1 278 11 275 305 9.7 0 9.7 9.7 07/25/2005 16:20:00 2.8 0.4 3.8 1.9 2.7 0.5 4.2 1.1 285 11 266 305 9.7 0 10 9.7 07/25/2005 16:30:00 2.8 0.5 4.6 1.9 2.7 0.4 4.2 1.5 284 10 288 305 9.9 0 10 9.7 07/25/2005 16:40:00 2.6 0.5 3.8 1.1 2.4 0.5 3.8 1.1 279 12 277 305 9.9 0 10.2 9.7 07/25/2005 16:50:00 2.1 0.4 3.4 0.7 2 0.4 3.4 0.7 267 16 258 305 9.7 0 10 9.5 07/25/2005 17:00:00 2.6 0.4 3.4 1.5 2.2 0.4 3.4 1.1 270 13 266 305 9.5 0 9.7 9.2 07/25/2005 17:10:00 2.7 0.5 3.8 1.5 2.2 0.5 3.4 0.7 260 11 266 305 9.3 0 9.5 9.2 07/25/2005 17:20:00 2.9 0.5 3.8 1.9 2.4 0.5 3.8 1.1 269 11 258 305 9.3 0 9.5 9.2 07/25/2005 17:30:00 2.6 0.5 4.2 1.5 2.3 0.5 3.8 1.1 276 13 283 305 9.3 0 9.5 9.2 07/25/2005 17:40:00 2.9 0.5 4.2 1.9 2.6 0.5 4.2 1.5 277 9 273 305 9.3 0 9.5 9.2 07/25/2005 17:50:00 2.8 0.5 3.8 1.5 2.4 0.4 3.4 1.5 263 13 275 305 9.2 0 9.5 9.2 07/25/2005 18:00:00 3.3 0.6 4.6 1.9 2.8 0.5 4.2 1.5 262 9 263 305 9.1 0 9.5 8.9 07/25/2005 18:10:00 3 0.5 4.6 1.9 2.7 0.6 4.2 1.1 260 11 256 305 9 0 9.2 8.9 07/25/2005 18:20:00 3.1 0.4 4.2 1.9 2.7 0.5 4.2 1.5 257 9 239 305 9.1 0 9.2 9.2 07/25/2005 18:30:00 3.4 0.5 4.9 2.3 3 0.6 4.2 1.5 258 10 256 305 8.9 0 9.2 8.9 07/25/2005 18:40:00 3 0.5 4.2 1.9 2.7 0.5 3.8 1.1 250 15 268 305 9 0 9.2 8.9 07/25/2005 18:50:00 3.1 0.5 4.2 1.9 2.9 0.5 3.8 1.1 251 10 231 305 8.9 0 9.2 8.9 07/25/2005 19:00:00 3.1 0.5 4.6 1.9 2.8 0.5 4.2 1.5 256 8 254 305 8.8 0 8.9 8.7 07/25/2005 19:10:00 3.1 0.4 4.2 1.9 2.7 0.5 4.2 1.5 257 11 256 305 8.7 0 8.9 8.7 07/25/2005 19:20:00 3.5 0.6 4.9 1.9 3.4 0.6 4.6 1.9 247 8 240 305 8.7 0 8.9 8.4 07/25/2005 19:30:00 3.4 0.5 4.9 2.6 3.2 0.5 4.9 1.9 244 9 242 305 8.7 0 8.9 8.4 07/25/2005 19:40:00 3.1 0.4 4.2 1.9 2.7 0.4 3.8 1.9 258 9 261 305 8.7 0 8.9 8.4 07/25/2005 19:50:00 3.5 0.5 4.9 2.3 3.2 0.5 4.9 1.9 249 9 254 305 8.7 0 8.9 8.4 07/25/2005 20:00:00 2.7 0.4 3.8 1.9 2.5 0.4 3.4 1.5 248 11 258 305 8.8 0 8.9 8.7 07/25/2005 20:10:00 3.2 0.5 4.6 1.9 2.8 0.5 4.2 1.5 255 8 258 305 8.6 0 8.9 8.7 07/25/2005 20:20:00 2.6 0.4 3.8 1.5 2.4 0.4 3.4 1.1 247 12 268 305 8.7 0 8.9 8.4 07/25/2005 20:30:00 2.5 0.3 3 1.9 2.3 0.4 3 1.5 248 7 254 305 8.7 0 8.9 8.7 07/25/2005 20:40:00 2.5 0.5 3.8 1.5 2.1 0.5 3.8 0.7 256 11 237 305 8.7 0 8.9 8.7 07/25/2005 20:50:00 2.5 0.5 3.4 1.1 2.2 0.5 3.4 1.1 251 12 268 305 8.8 0 8.9 8.7 07/25/2005 21:00:00 3.1 0.5 4.2 1.9 2.6 0.5 4.2 1.5 254 9 265 305 8.6 0 8.9 8.4 07/25/2005 21:10:00 2.9 0.5 4.2 1.9 2.7 0.5 4.2 1.5 248 9 247 305 8.6 0 8.9 8.4 07/25/2005 21:20:00 3.2 0.5 4.6 1.9 2.9 0.5 4.2 1.9 243 9 232 305 8.6 0 8.9 8.4 07/25/2005 21:30:00 2.7 0.4 3.8 1.5 2.5 0.4 3.8 1.5 246 9 248 305 8.6 0 9.2 8.4 07/25/2005 21:40:00 3 0.4 3.8 1.9 2.8 0.4 3.4 1.5 235 11 225 305 8.6 0 8.9 8.4 07/25/2005 21:50:00 2.6 0.5 3.8 1.5 2.3 0.4 3.4 1.5 244 8 254 305 8.3 0 8.4 8.2 07/25/2005 22:00:00 2.6 0.6 4.2 1.5 2.4 0.5 3.4 1.5 238 9 236 305 8.4 0 8.4 7.9 07/25/2005 22:10:00 2.9 0.5 4.2 1.9 2.7 0.5 3.8 1.9 235 10 239 305 8.4 0 8.7 8.2 07/25/2005 22:20:00 3.1 0.4 4.2 2.3 2.9 0.4 3.8 1.9 237 8 239 305 8.5 0 8.7 8.2 07/25/2005 22:30:00 3.4 0.4 4.6 2.3 3.1 0.4 4.2 2.3 237 6 242 305 8.4 0 8.4 8.2 07/25/2005 22:40:00 3.7 0.4 4.6 2.6 3.4 0.5 4.6 2.3 233 6 242 305 8.3 0 8.4 8.2 07/25/2005 22:50:00 4.2 0.5 5.3 3 3.8 0.4 4.9 2.6 239 7 236 305 8.1 0 8.2 7.9 07/25/2005 23:00:00 3.8 0.4 4.9 3 3.4 0.4 4.2 2.3 231 6 228 305 8.2 0 8.2 8.2 07/25/2005 23:10:00 3.7 0.4 4.6 2.6 3.5 0.4 4.6 2.6 231 6 225 305 8.1 0 8.2 8.2 07/25/2005 23:20:00 4.1 0.4 4.9 3 3.6 0.4 4.6 2.6 238 6 242 305 8.1 0 8.2 7.9 07/25/2005 23:30:00 4 0.4 4.9 2.6 3.7 0.4 4.6 2.6 241 6 244 305 8.1 0 8.2 7.9 07/25/2005 23:40:00 4.2 0.5 5.3 3 3.8 0.5 4.9 2.6 239 6 242 305 8 0 8.2 7.9 07/25/2005 23:50:00 4.3 0.4 5.3 3 3.8 0.4 4.9 3 242 6 247 305 8 0 8.2 7.9 07/26/2005 00:00:00 4 0.5 4.9 2.6 3.7 0.5 4.9 2.6 247 6 242 305 8 0 8.4 7.9 07/26/2005 00:10:00 4 0.4 4.9 3 3.6 0.4 4.6 2.6 245 8 252 305 7.9 0 8.2 7.7 07/26/2005 00:20:00 3.7 0.5 4.6 2.3 3.4 0.5 4.6 2.3 236 8 239 305 8 0 8.4 7.9 07/26/2005 00:30:00 3.4 0.5 4.9 2.3 3.1 0.5 4.2 1.9 234 6 237 305 8 0 8.4 7.9 07/26/2005 00:40:00 2.6 0.6 4.2 1.1 2.4 0.6 3.8 1.1 234 12 228 305 8.1 0 8.7 8.2 07/26/2005 00:50:00 2.5 0.4 3.4 1.5 2.3 0.4 3.4 0.7 242 13 242 305 8.2 0.1 8.7 8.2 07/26/2005 01:00:00 2.7 0.6 3.8 0.7 2.3 0.5 3.4 0.7 241 12 234 305 8.4 0.1 8.7 8.2 07/26/2005 01:10:00 2.8 0.6 4.2 1.1 2.5 0.6 4.2 0.7 244 10 250 305 8.4 0 8.9 8.2 07/26/2005 01:20:00 2.7 0.6 4.2 1.1 2.5 0.6 3.8 1.1 246 6 246 305 8.5 0 8.9 8.2 07/26/2005 01:30:00 4.6 0.4 5.3 3.4 4.1 0.5 4.9 2.6 248 6 252 305 8.3 0 8.9 8.2 07/26/2005 01:40:00 5.2 0.5 6.5 3.8 4.7 0.6 6.1 2.6 242 5 243 305 8.3 0.1 8.9 7.9 07/26/2005 01:50:00 5.1 0.5 6.1 3.4 4.6 0.6 6.1 3 250 5 250 305 8.1 0 8.4 7.9 07/26/2005 02:00:00 4.1 0.5 5.3 2.6 3.5 0.6 4.9 2.3 253 6 253 305 8 0 8.4 7.9 07/26/2005 02:10:00 4.3 0.6 6.1 3 3.9 0.6 5.7 2.3 247 6 242 305 8 0 8.4 7.9 07/26/2005 02:20:00 4.4 0.5 5.7 3 4 0.5 5.7 3 246 6 246 305 8 0 8.2 7.9 07/26/2005 02:30:00 3.6 0.4 4.6 2.6 3.3 0.4 4.2 2.3 238 5 236 305 8 0 8.2 7.9 07/26/2005 02:40:00 3.8 0.4 4.6 2.6 3.3 0.5 4.6 2.3 244 7 251 305 8.1 0 8.2 7.9 07/26/2005 02:50:00 3.7 0.4 4.9 2.6 3.4 0.4 4.6 2.6 246 8 255 305 8.1 0 8.2 7.9 07/26/2005 03:00:00 4.4 0.7 5.7 2.6 3.9 0.7 5.3 2.6 239 5 241 305 8.1 0 8.2 7.9 07/26/2005 03:10:00 4.5 0.4 5.7 3 4 0.4 4.9 2.6 244 6 238 305 8 0 8.2 7.9 07/26/2005 03:20:00 5 0.5 5.7 3.8 4.4 0.5 5.7 3 241 6 244 305 8 0 8.2 7.9 07/26/2005 03:30:00 4.6 0.5 5.7 3.4 4.1 0.5 5.3 3 238 5 243 305 8 0 8.2 7.9 07/26/2005 03:40:00 4.7 0.4 5.7 3.4 4.3 0.4 5.3 3 239 6 239 305 8 0 8.2 7.9 07/26/2005 03:50:00 4.2 0.5 5.3 3 3.8 0.5 5.3 2.6 245 8 243 305 7.9 0 7.9 7.9 07/26/2005 04:00:00 4.3 0.5 5.3 2.6 3.9 0.6 4.9 2.3 239 6 239 305 8 0 8.2 7.9 07/26/2005 04:10:00 3.7 0.5 4.9 2.3 3.3 0.5 5.3 2.3 245 11 247 305 8 0 8.2 7.9 07/26/2005 04:20:00 3.8 0.5 4.6 2.3 3.3 0.5 4.6 2.3 245 8 244 305 8 0 8.2 7.9 07/26/2005 04:30:00 4.3 0.5 5.7 3 4 0.4 5.3 3 233 7 236 305 8.2 0 8.7 8.2 07/26/2005 04:40:00 4.7 0.6 5.7 3 4.2 0.6 5.7 2.6 241 10 241 305 8.2 0.2 8.9 8.2 07/26/2005 04:50:00 4.4 0.6 5.7 2.6 4.1 0.6 5.3 2.6 242 6 246 305 8.2 0.1 8.7 8.2 07/26/2005 05:00:00 4.8 0.6 6.1 3.8 4.4 0.6 5.7 3 240 7 242 305 8.2 0.1 8.9 8.2 07/26/2005 05:10:00 5.2 0.5 6.5 4.2 4.7 0.6 6.1 3 241 6 238 305 8.1 0 8.7 7.9 07/26/2005 05:20:00 4.9 0.5 6.1 3.4 4.3 0.5 5.7 3 239 5 241 305 7.9 0 8.4 7.9 07/26/2005 05:30:00 5 0.7 6.5 3.4 4.4 0.6 5.7 3 238 6 238 305 7.9 0.1 8.2 7.7 07/26/2005 05:40:00 5.2 0.5 6.5 3.4 4.7 0.6 6.1 3.4 240 5 243 305 7.8 0.1 8.2 7.7 07/26/2005 05:50:00 4.8 0.5 6.1 3.4 4.2 0.5 5.3 3 241 6 245 305 7.7 0 8.2 7.7 07/26/2005 06:00:00 4.8 0.5 6.1 3.4 4.4 0.5 5.7 3 240 7 234 305 7.6 0 7.9 7.7 07/26/2005 06:10:00 4.3 0.4 5.7 3.4 3.9 0.4 5.3 2.6 236 7 242 305 7.6 0 7.9 7.7 07/26/2005 06:20:00 4.7 0.4 6.1 3.4 4.2 0.5 5.3 3 233 6 244 305 7.6 0 7.9 7.4 07/26/2005 06:30:00 4.5 0.4 5.3 3 4.1 0.5 5.3 3 231 6 231 305 7.5 0 7.9 7.4 07/26/2005 06:40:00 4 0.5 5.3 2.6 3.7 0.4 4.6 2.3 236 6 240 305 7.5 0 7.9 7.4 07/26/2005 06:50:00 4.2 0.5 5.3 3 3.8 0.5 4.9 2.6 237 6 234 305 7.5 0 7.9 7.4 07/26/2005 07:00:00 4.3 0.4 5.7 3.4 4 0.5 5.3 3 236 7 234 305 7.5 0 7.7 7.4 07/26/2005 07:10:00 4.2 0.4 5.3 3 3.9 0.4 4.9 2.6 233 7 224 305 7.5 0 7.7 7.4 07/26/2005 07:20:00 4.4 0.4 5.3 3.4 4 0.5 5.3 3 234 7 234 305 7.5 0 7.7 7.7 07/26/2005 07:30:00 4 0.5 5.3 2.6 3.7 0.5 4.9 2.3 239 7 237 305 7.5 0 7.7 7.4 07/26/2005 07:40:00 4.3 0.6 5.7 2.6 3.8 0.6 4.9 2.6 239 6 239 305 7.5 0 7.7 7.4 07/26/2005 07:50:00 4.8 0.6 6.1 3 4.4 0.6 6.1 2.6 245 5 244 305 7.3 0 7.7 7.2 07/26/2005 08:00:00 4.5 0.4 5.3 3.4 4.1 0.4 4.9 2.6 238 6 237 305 7.4 0 7.7 7.4 07/26/2005 08:10:00 4.4 0.6 5.7 2.6 4.1 0.6 5.7 2.6 236 7 231 305 7.5 0 7.7 7.4 07/26/2005 08:20:00 4.5 0.5 5.7 3 4.1 0.5 5.3 2.6 238 6 232 305 7.5 0 7.7 7.4 07/26/2005 08:30:00 4.9 0.4 5.7 3.4 4.5 0.5 5.7 3.4 229 7 232 305 7.6 0 7.7 7.7 07/26/2005 08:40:00 4.8 0.5 6.1 3.8 4.5 0.5 5.7 3 230 6 225 305 7.6 0 7.7 7.7 07/26/2005 08:50:00 5.2 0.4 6.1 4.2 4.8 0.5 6.5 3.8 234 8 224 305 7.4 0 7.7 7.2 07/26/2005 09:00:00 4.6 0.5 6.1 3 4.3 0.5 5.7 3 235 9 244 305 7.5 0 7.9 7.4 07/26/2005 09:10:00 5.2 0.5 6.1 3.8 4.7 0.5 6.1 3 241 5 239 305 7.5 0 7.9 7.4 07/26/2005 09:20:00 4.9 0.5 6.1 3 4.6 0.6 6.1 3 236 5 239 305 7.6 0 8.2 7.4 07/26/2005 09:30:00 4.5 0.4 5.7 3.4 4.2 0.5 5.3 3 229 6 230 305 7.7 0 8.2 7.7 07/26/2005 09:40:00 5.1 0.6 6.5 3.8 4.8 0.7 6.5 3.4 243 8 238 305 7.7 0 8.2 7.7 07/26/2005 09:50:00 4.4 0.6 6.1 2.6 4.1 0.6 5.7 2.6 229 7 238 305 7.9 0 8.4 7.7 07/26/2005 10:00:00 4.3 0.5 5.7 3 4.1 0.5 5.3 3 226 10 232 305 7.9 0.1 8.4 7.7 07/26/2005 10:10:00 3.6 0.4 4.6 2.3 3.5 0.4 4.6 2.3 218 8 224 305 8 0 8.4 7.9 07/26/2005 10:20:00 3.9 0.4 4.9 3 3.7 0.4 4.6 2.6 227 10 224 305 8.1 0.1 8.7 7.9 07/26/2005 10:30:00 4.2 0.4 5.3 3 4 0.5 5.7 2.6 222 8 222 305 8.2 0.1 8.7 7.9 07/26/2005 10:40:00 4.8 0.4 5.7 3.8 4.6 0.5 5.7 3 231 8 220 305 8.1 0 8.7 7.9 07/26/2005 10:50:00 4.8 0.4 6.1 3.4 4.5 0.4 5.3 3.4 229 5 221 305 8.2 0 8.7 7.9 07/26/2005 11:00:00 5.1 0.5 6.1 3.8 4.8 0.5 5.7 3.4 224 5 218 305 8.1 0.1 8.7 7.9 07/26/2005 11:10:00 5.5 0.5 6.8 4.2 5.2 0.6 6.5 3.4 236 7 239 305 8 0.1 8.7 7.9 07/26/2005 11:20:00 5 0.6 6.5 3.4 4.6 0.6 6.1 3.4 235 6 246 305 8.2 0.1 8.7 7.9 07/26/2005 11:30:00 4.9 0.5 6.1 3.4 4.4 0.5 5.7 3 233 7 234 305 8.2 0.1 8.7 7.9 07/26/2005 11:40:00 4.5 0.5 5.7 2.6 4.2 0.4 5.3 3 225 10 230 305 8.2 0.1 8.9 8.2 07/26/2005 11:50:00 4.7 0.6 6.1 3.4 4.4 0.6 5.7 3 227 6 234 305 8.3 0.1 8.9 8.2 07/26/2005 12:00:00 5.2 0.5 6.5 3.4 4.9 0.6 6.1 3 226 6 227 305 8.4 0 8.7 8.2 07/26/2005 12:10:00 5.3 0.5 6.8 4.2 5.1 0.5 6.5 3.8 224 6 228 305 8.4 0 8.7 8.2 07/26/2005 12:20:00 5.7 0.5 6.8 4.2 5.4 0.5 6.8 3.8 219 6 213 305 8.4 0 8.7 8.2 07/26/2005 12:30:00 5.4 0.5 6.8 4.2 5.2 0.5 6.5 3.8 226 6 231 305 8.3 0.1 8.7 8.2 07/26/2005 12:40:00 4.7 0.5 6.5 3.4 4.5 0.5 5.7 3 227 8 220 305 8.2 0 8.4 8.2 07/26/2005 12:50:00 5.1 0.5 6.1 3.4 4.8 0.5 6.1 3.4 218 6 212 305 8.4 0 8.7 8.2 07/26/2005 13:00:00 5.8 0.5 6.8 4.2 5.5 0.5 6.8 3.4 222 6 224 305 8.4 0 8.4 8.2 07/26/2005 13:10:00 5.7 0.5 7.2 4.6 5.4 0.6 6.8 3.8 223 6 218 305 8.4 0 8.7 8.2 07/26/2005 13:20:00 6 0.4 6.8 4.6 5.6 0.5 6.8 3.8 224 5 218 305 8.2 0 8.4 8.2 07/26/2005 13:30:00 5.3 0.7 6.5 3 5.1 0.7 6.8 3 227 8 229 305 8.1 0 8.2 7.9 07/26/2005 13:40:00 5.2 0.7 6.8 3.4 5 0.7 6.8 3.4 228 6 228 305 8.2 0 8.4 7.9 07/26/2005 13:50:00 5.4 0.6 6.8 3.8 5.2 0.6 6.5 3.8 234 6 236 305 7.9 0 8.2 7.7 07/26/2005 14:00:00 4.9 0.5 6.5 3.4 4.7 0.6 6.1 3 224 7 235 305 8.1 0 8.2 7.9 07/26/2005 14:10:00 5.2 0.5 6.5 3.8 5 0.5 6.1 3.8 223 5 225 305 8 0 8.4 7.9 07/26/2005 14:20:00 5.2 0.6 6.5 3.8 5.1 0.6 6.5 3.4 226 7 224 305 8.2 0 8.4 7.9 07/26/2005 14:30:00 4.9 0.5 6.1 3.4 4.7 0.5 5.7 3.4 227 8 234 305 8.2 0 8.4 7.9 07/26/2005 14:40:00 5.3 0.5 6.1 4.2 5.1 0.5 6.5 3.8 227 7 229 305 7.9 0.1 8.2 7.7 07/26/2005 14:50:00 5.5 0.5 7.2 4.2 5.3 0.6 6.5 3.4 230 7 241 305 7.9 0.1 8.2 7.7 07/26/2005 15:00:00 5 0.6 6.5 3.4 4.8 0.6 6.1 3.4 231 9 214 305 8 0.1 8.4 7.7 07/26/2005 15:10:00 5.5 0.5 6.8 3.8 5.2 0.5 6.5 3.8 245 9 255 305 8.1 0 8.2 7.9 07/26/2005 15:20:00 5.6 0.6 7.2 4.6 5.3 0.6 6.8 3.8 239 9 253 305 8.1 0 8.2 7.9 07/26/2005 15:30:00 5.3 0.5 6.5 4.2 5.1 0.5 6.1 3.8 232 7 241 305 8.2 0 8.4 8.2 07/26/2005 15:40:00 5.6 0.5 6.8 4.2 5.3 0.5 6.8 4.2 231 6 230 305 8.1 0 8.7 7.9 07/26/2005 15:50:00 5.3 0.5 6.5 4.2 5.1 0.5 6.1 3.8 235 6 240 305 8.2 0.1 8.4 7.9 07/26/2005 16:00:00 5 0.5 6.5 3.4 4.9 0.5 6.1 3.4 235 8 239 305 8.1 0 8.2 7.9 07/26/2005 16:10:00 5.2 0.4 6.1 3.8 5 0.5 6.1 3.8 237 6 242 305 8.1 0 8.4 7.9 07/26/2005 16:20:00 5.4 0.6 6.5 3.8 5.2 0.6 6.5 3.8 234 7 247 305 8.2 0 8.4 8.2 07/26/2005 16:30:00 5.5 0.4 6.5 3.8 5.2 0.4 6.1 4.2 230 7 237 305 8.4 0 8.7 8.2 07/26/2005 16:40:00 5.2 0.4 6.5 3.8 5 0.4 6.1 3.8 228 7 234 305 8.4 0 8.9 8.2 07/26/2005 16:50:00 5.3 0.5 6.8 3.8 5.1 0.5 6.5 3.8 228 7 222 305 8.6 0 8.7 8.2 07/26/2005 17:00:00 4.7 0.6 6.1 3 4.5 0.5 5.7 3 235 8 238 305 8.6 0 8.7 8.2 07/26/2005 17:10:00 4.7 0.5 6.1 3.4 4.6 0.5 5.7 3.4 227 6 229 305 8.4 0.1 8.9 8.2 07/26/2005 17:20:00 4.7 0.5 5.7 3.4 4.5 0.5 5.3 3 234 9 244 305 8.4 0 8.7 8.2 07/26/2005 17:30:00 4.7 0.4 5.7 3.4 4.5 0.5 5.7 2.6 230 8 238 305 8.2 0 8.7 7.9 07/26/2005 17:40:00 4.5 0.5 5.7 3 4.3 0.5 5.7 3 223 8 220 305 8.6 0 8.7 8.2 07/26/2005 17:50:00 5.4 0.7 7.6 3.8 5.1 0.7 6.5 3 231 7 219 305 8.4 0.2 8.7 8.2 07/26/2005 18:00:00 5.5 0.5 6.5 4.2 5.2 0.5 6.1 3.8 225 6 229 305 8.3 0.2 8.7 8.2 07/26/2005 18:10:00 5 0.5 6.5 3.8 4.8 0.5 6.1 3.4 223 7 229 305 8.3 0.1 8.7 7.9 07/26/2005 18:20:00 4.9 0.5 6.1 3.8 4.7 0.5 5.7 3 227 8 222 305 8.1 0 8.2 7.9 07/26/2005 18:30:00 4.7 0.6 6.1 3.4 4.4 0.6 5.7 2.6 225 7 232 305 8.2 0 8.4 8.2 07/26/2005 18:40:00 5 0.5 6.5 3.4 4.8 0.5 6.1 3.4 227 6 229 305 8.2 0 8.4 7.9 07/26/2005 18:50:00 5.1 0.4 6.1 3.8 4.9 0.4 5.7 3.8 223 6 221 305 8.2 0 8.4 7.9 07/26/2005 19:00:00 5 0.4 6.5 3.8 4.9 0.5 6.1 3.4 223 6 224 305 8.3 0.2 8.7 7.9 07/26/2005 19:10:00 5.3 0.4 6.5 4.2 5.2 0.4 6.1 3.8 219 7 212 305 8.3 0.2 8.7 8.2 07/26/2005 19:20:00 5 0.5 6.1 3.4 4.8 0.5 6.1 3.4 217 6 222 305 8.3 0 8.4 8.2 07/26/2005 19:30:00 4.8 0.4 5.7 3.4 4.6 0.4 5.7 3 218 5 222 305 8.2 0 8.4 8.2 07/26/2005 19:40:00 4.7 0.4 5.7 3.8 4.5 0.5 6.1 3 214 7 207 305 8.2 0 8.4 8.2 07/26/2005 19:50:00 4.8 0.5 5.7 3 4.6 0.5 5.7 3.4 215 6 221 305 8.1 0 8.2 7.9 07/26/2005 20:00:00 4.7 0.4 5.7 3.8 4.6 0.5 5.7 3.4 217 6 218 305 8.1 0 8.2 7.9 07/26/2005 20:10:00 4.8 0.4 5.7 3.4 4.7 0.4 5.7 3 218 5 220 305 8 0 8.2 7.9 07/26/2005 20:20:00 4.9 0.5 6.1 3 4.7 0.5 6.1 3 214 7 217 305 8.2 0.1 8.4 7.9 07/26/2005 20:30:00 5.2 0.5 6.5 3.4 5 0.6 6.1 3.4 214 5 195 305 8.2 0 8.4 8.2 07/26/2005 20:40:00 4.5 0.6 5.7 2.6 4.2 0.6 5.7 2.6 209 8 221 305 8.3 0 8.4 8.2 07/26/2005 20:50:00 4.6 0.5 5.7 3 4.4 0.6 5.3 2.3 209 7 203 305 8.5 0 8.7 8.4 07/26/2005 21:00:00 4.7 0.4 5.7 3.4 4.5 0.5 5.7 2.6 210 7 217 305 8.4 0.1 8.7 8.2 07/26/2005 21:10:00 5 0.5 6.1 3.4 4.8 0.5 6.1 3.4 210 5 213 305 8 0 8.2 7.9 07/26/2005 21:20:00 5.4 0.6 6.5 3.8 5.2 0.7 6.8 3.4 210 7 207 305 7.9 0 8.2 7.7 07/26/2005 21:30:00 5.5 0.4 6.5 3.8 5.3 0.4 6.5 4.2 208 6 213 305 7.7 0 7.9 7.7 07/26/2005 21:40:00 5.6 0.5 6.5 4.2 5.4 0.5 6.5 3.8 211 6 215 305 7.5 0 7.7 7.4 07/26/2005 21:50:00 5.6 0.5 6.5 4.2 5.3 0.6 6.5 3.8 213 5 214 305 7.6 0 7.7 7.7 07/26/2005 22:00:00 5.7 0.6 6.8 3.8 5.5 0.6 6.8 3.8 214 6 214 305 7.7 0 7.9 7.7 07/26/2005 22:10:00 6.1 0.5 7.2 4.2 6.1 0.5 7.6 4.2 208 5 210 305 7.6 0 7.7 7.7 07/26/2005 22:20:00 6.4 0.5 7.6 4.6 6.3 0.6 7.2 4.6 211 5 206 305 7.5 0 7.7 7.4 07/26/2005 22:30:00 6 0.6 7.2 4.2 5.6 0.6 6.8 3.8 212 6 210 305 7.5 0 7.7 7.4 07/26/2005 22:40:00 6.4 0.5 7.2 4.6 6.1 0.6 7.2 4.6 215 5 215 305 7.5 0 7.7 7.4 07/26/2005 22:50:00 6.8 0.5 7.6 4.9 6.5 0.6 7.6 4.6 218 5 216 305 7.4 0 7.7 7.2 07/26/2005 23:00:00 6.5 0.5 8 4.6 6.1 0.6 7.2 4.2 213 5 218 305 7.3 0 7.4 7.2 07/26/2005 23:10:00 6.1 0.5 7.2 4.6 5.9 0.6 7.2 4.2 213 5 218 305 7.2 0 7.4 7.2 07/26/2005 23:20:00 5.6 0.6 6.8 4.2 5.3 0.7 6.8 3.8 212 6 217 305 7.2 0 7.4 7.2 07/26/2005 23:30:00 5.2 0.5 6.5 3.8 5 0.6 6.5 3.4 211 6 217 305 7.1 0 7.4 7.2 07/26/2005 23:40:00 5.4 0.6 6.8 3.4 5.3 0.6 6.5 3.4 208 6 215 305 7 0 7.2 6.9 07/26/2005 23:50:00 5.5 0.4 6.5 4.2 5.5 0.5 6.5 3.8 206 4 207 305 7 0 7.2 6.9 07/27/2005 00:00:00 5.5 0.5 6.8 4.2 5.3 0.5 6.5 3.8 209 6 214 305 7 0 7.2 6.9 07/27/2005 00:10:00 5.8 0.5 6.8 4.2 5.6 0.6 6.8 3.8 209 4 208 305 7 0 7.4 6.9 07/27/2005 00:20:00 5.8 0.5 6.8 4.2 5.6 0.5 6.8 3.8 210 5 207 305 7 0 7.4 6.9 07/27/2005 00:30:00 5.8 0.5 6.8 4.6 5.7 0.6 6.8 3.8 210 4 210 305 7 0 7.4 6.9 07/27/2005 00:40:00 5.6 0.6 6.8 3.8 5.3 0.6 6.8 3.8 211 5 210 305 7 0 7.2 6.9 07/27/2005 00:50:00 5.6 0.5 6.8 4.2 5.4 0.6 6.5 3.4 209 5 213 305 7 0 7.2 6.9 07/27/2005 01:00:00 5.7 0.5 6.8 3.8 5.3 0.6 6.5 3.8 212 5 214 305 7 0 7.2 6.9 07/27/2005 01:10:00 6 0.5 6.8 4.2 5.8 0.5 6.8 4.2 212 5 212 305 7 0 7.2 6.9 07/27/2005 01:20:00 6 0.4 6.8 4.6 5.8 0.5 6.8 4.2 218 5 218 305 7 0 7.2 6.9 07/27/2005 01:30:00 6.1 0.5 7.2 4.2 5.9 0.6 7.2 4.2 212 5 208 305 7 0 7.2 6.9 07/27/2005 01:40:00 5.9 0.5 7.2 4.2 5.8 0.5 6.8 4.2 209 6 222 305 7 0 7.2 7.2 07/27/2005 01:50:00 6.1 0.5 7.2 4.2 5.8 0.6 7.2 4.2 209 6 205 305 7.2 0 7.4 7.2 07/27/2005 02:00:00 6.7 0.6 8 4.6 6.4 0.8 8 4.2 211 6 208 305 7.3 0 7.4 7.2 07/27/2005 02:10:00 7.6 0.6 8.8 4.6 7.4 0.7 9.1 4.9 211 4 205 305 7.3 0 7.4 7.4 07/27/2005 02:20:00 7.5 0.4 8.4 6.1 7.2 0.6 8.4 5.3 215 4 213 305 7.3 0 7.4 7.2 07/27/2005 02:30:00 7.2 0.6 8.4 5.3 6.9 0.6 8 4.9 214 4 214 305 7.2 0 7.4 7.2 07/27/2005 02:40:00 6.7 0.6 8 4.9 6.3 0.6 8 4.9 214 6 206 305 7.5 0 7.7 7.4 07/27/2005 02:50:00 6.4 0.5 7.6 4.9 6 0.6 7.6 4.2 217 5 218 305 7.5 0 7.7 7.4 07/27/2005 03:00:00 6.1 0.6 7.6 4.6 5.7 0.6 7.6 4.2 219 5 224 305 7.6 0 7.7 7.7 07/27/2005 03:10:00 5.8 0.5 7.2 4.6 5.4 0.5 6.8 4.2 219 7 230 305 7.7 0 7.9 7.7 07/27/2005 03:20:00 5.6 0.5 6.8 4.2 5.3 0.6 6.8 3.8 219 5 229 305 7.8 0 8.2 7.7 07/27/2005 03:30:00 5.6 0.5 6.8 4.2 5.3 0.5 6.8 3.8 216 5 218 305 8 0 8.2 7.9 07/27/2005 03:40:00 5.4 0.6 6.8 3.8 5.1 0.6 6.8 3.4 219 6 221 305 8 0 8.2 7.9 07/27/2005 03:50:00 4.9 0.5 6.1 3.8 4.7 0.5 5.7 3.4 220 5 218 305 8 0 8.4 7.9 07/27/2005 04:00:00 4.5 0.5 5.7 3 4.3 0.5 5.3 2.6 210 6 212 305 8.1 0 8.4 7.9 07/27/2005 04:10:00 4.4 0.5 6.1 3 4.1 0.4 5.7 3 215 8 221 305 8.2 0 8.4 8.2 07/27/2005 04:20:00 4.1 0.4 5.3 2.6 3.9 0.4 4.9 2.6 217 8 232 305 8.2 0 8.9 8.2 07/27/2005 04:30:00 4.5 0.4 5.7 3.4 4.2 0.4 5.3 3 228 8 225 305 8.3 0 8.7 8.2 07/27/2005 04:40:00 4.6 0.6 6.1 3 4.3 0.6 5.7 2.6 232 9 239 305 8.3 0.1 8.7 8.2 07/27/2005 04:50:00 4.5 0.4 5.7 3.4 4.1 0.5 5.3 2.6 219 5 220 305 8.4 0 8.7 8.2 07/27/2005 05:00:00 4 0.5 4.9 2.6 3.8 0.5 4.9 2.6 211 5 213 305 8.5 0 8.7 8.4 07/27/2005 05:10:00 4.1 0.4 4.9 2.6 3.8 0.5 4.9 2.6 214 5 218 305 8.6 0 8.9 8.4 07/27/2005 05:20:00 4.6 0.4 5.3 3.4 4.3 0.5 5.3 3 213 5 218 305 8.6 0 8.9 8.4 07/27/2005 05:30:00 4.7 0.5 6.1 3.4 4.4 0.6 5.7 3 210 5 214 305 8.7 0 8.9 8.7 07/27/2005 05:40:00 5.2 0.5 6.1 3.8 4.8 0.5 6.1 3 213 6 214 305 8.8 0 8.9 8.7 07/27/2005 05:50:00 5.4 0.4 6.5 4.6 5.3 0.4 6.1 3.8 201 5 201 305 8.7 0 8.9 8.7 07/27/2005 06:00:00 5.4 0.4 6.1 4.6 5.3 0.4 6.1 3.4 207 4 208 305 8.7 0 8.9 8.7 07/27/2005 06:10:00 5.6 0.4 7.2 4.2 5.5 0.4 6.8 4.2 204 5 203 305 8.6 0 8.9 8.4 07/27/2005 06:20:00 5.3 0.5 6.8 3.8 5.2 0.5 6.5 4.2 203 6 197 305 8.7 0 8.9 8.7 07/27/2005 06:30:00 4.9 0.5 6.1 3.8 4.7 0.5 6.1 3.8 203 7 200 305 8.8 0 8.9 8.7 07/27/2005 06:40:00 5.2 0.6 6.8 3 4.9 0.6 6.1 3.4 221 8 230 305 8.7 0 8.9 8.7 07/27/2005 06:50:00 5.5 0.5 6.5 4.2 5.1 0.5 6.5 3.8 227 6 221 305 8.7 0 8.9 8.7 07/27/2005 07:00:00 5 0.5 6.1 3.8 4.6 0.6 5.7 3 234 7 242 305 8.7 0 8.9 8.7 07/27/2005 07:10:00 4.8 0.5 6.1 3.4 4.5 0.5 5.7 3.4 228 8 229 305 8.6 0 8.9 8.4 07/27/2005 07:20:00 4.9 0.5 6.1 3.4 4.5 0.5 5.7 3 229 7 220 305 8.6 0 8.7 8.4 07/27/2005 07:30:00 5.4 0.5 6.5 4.2 5 0.5 6.5 3.4 234 5 228 305 8.4 0 8.4 8.2 07/27/2005 07:40:00 4.7 0.4 5.7 3 4.5 0.5 5.3 3 216 5 218 305 8.4 0 8.7 8.2 07/27/2005 07:50:00 4.6 0.4 5.3 3 4.4 0.5 5.7 3 215 5 213 305 8.5 0 8.9 8.4 07/27/2005 08:00:00 4.7 0.6 5.7 3 4.4 0.6 5.7 3 213 5 214 305 8.5 0 8.9 8.4 07/27/2005 08:10:00 4.7 0.6 5.7 3 4.4 0.6 5.7 3 218 5 218 305 8.5 0 8.9 8.4 07/27/2005 08:20:00 4.8 0.5 6.1 3 4.6 0.6 5.7 3 213 6 214 305 8.5 0 9.2 8.4 07/27/2005 08:30:00 5.5 0.4 6.5 3.8 5.2 0.5 6.5 3.8 217 5 212 305 8.4 0.1 8.9 8.2 07/27/2005 08:40:00 5 0.5 6.1 3.4 4.8 0.6 5.7 3 213 5 218 305 8.2 0.1 8.9 8.2 07/27/2005 08:50:00 5.3 0.5 6.1 3.4 5.1 0.6 6.1 3.4 215 4 214 305 8.4 0.1 8.9 8.2 07/27/2005 09:00:00 5.3 0.5 6.5 3.8 5 0.7 6.5 3 215 5 214 305 8.5 0 9.2 8.2 07/27/2005 09:10:00 5.9 0.6 7.2 3.4 5.5 0.5 6.8 3.8 214 6 214 305 8.4 0 8.9 8.2 07/27/2005 09:20:00 6.7 0.5 8 4.9 6.4 0.6 8 4.6 213 5 211 305 8.5 0 8.9 8.2 07/27/2005 09:30:00 6.3 0.8 8 3.8 5.9 0.9 7.6 3.4 212 6 213 305 8.4 0 8.9 8.2 07/27/2005 09:40:00 6.1 0.6 7.2 4.2 5.6 0.7 7.2 3.4 215 6 219 305 8.4 0 8.9 8.2 07/27/2005 09:50:00 6.3 0.6 8 4.6 6 0.7 7.6 4.2 215 5 213 305 8.4 0.1 8.9 8.2 07/27/2005 10:00:00 6.4 0.6 8 4.2 6 0.7 8 4.2 214 6 206 305 8.5 0 8.9 8.2 07/27/2005 10:10:00 6.4 0.5 7.6 4.9 6.1 0.6 7.2 4.2 218 5 208 305 8.4 0 8.9 8.2 07/27/2005 10:20:00 5.8 0.5 6.8 3.4 5.5 0.6 6.8 3.8 214 7 230 305 8.4 0 8.7 8.2 07/27/2005 10:30:00 6.1 0.5 7.2 3.8 5.8 0.6 7.2 3.8 209 5 214 305 8.6 0 8.9 8.4 07/27/2005 10:40:00 6.7 0.5 8.4 4.9 6.3 0.6 7.6 4.6 209 4 209 305 8.6 0 8.7 8.4 07/27/2005 10:50:00 7.1 0.5 8.4 4.6 6.7 0.7 8 4.2 217 5 215 305 8.6 0 8.9 8.4 07/27/2005 11:00:00 6.7 0.6 8 4.6 6.3 0.6 7.6 4.2 215 5 198 305 8.6 0 8.9 8.4 07/27/2005 11:10:00 6.5 0.6 8 4.2 6.2 0.7 7.6 4.2 215 5 208 305 8.6 0 8.7 8.4 07/27/2005 11:20:00 6.7 0.7 8 4.9 6.3 0.7 8 4.6 226 5 225 305 8.8 0 8.9 8.4 07/27/2005 11:30:00 6.3 0.6 7.6 4.9 5.9 0.6 7.2 4.2 223 6 220 305 8.8 0 8.9 8.4 07/27/2005 11:40:00 6.4 0.6 7.6 4.6 6.1 0.7 7.6 4.2 218 7 234 305 8.8 0 8.9 8.7 07/27/2005 11:50:00 6 0.5 7.2 4.2 5.7 0.5 6.8 3.8 220 7 225 305 8.9 0 9.2 8.7 07/27/2005 12:00:00 6.5 0.5 7.6 4.9 6.2 0.6 7.2 4.6 226 5 219 305 9.1 0 9.2 8.9 07/27/2005 12:10:00 6.6 0.5 8 4.9 6.2 0.6 7.6 4.9 225 5 224 305 9.2 0 9.5 8.9 07/27/2005 12:20:00 6.9 0.5 8 5.7 6.6 0.5 7.6 4.6 226 6 230 305 9.1 0 9.5 8.9 07/27/2005 12:30:00 6.8 0.5 8 5.3 6.5 0.6 7.6 4.6 232 6 236 305 9.2 0 9.5 9.2 07/27/2005 12:40:00 6.9 0.7 8.4 4.9 6.6 0.8 8.4 4.6 220 6 217 305 9.7 0.1 10 9.2 07/27/2005 12:50:00 7.5 0.5 9.1 6.1 7.1 0.6 8.4 5.3 222 5 222 305 9.7 0 10 9.5 07/27/2005 13:00:00 7.7 0.5 9.1 6.1 7.3 0.7 8.4 5.3 226 6 232 305 9.4 0.1 9.7 9.2 07/27/2005 13:10:00 7.5 0.7 8.8 4.9 7.1 0.8 9.1 4.6 226 6 224 305 9.7 0.1 10 9.5 07/27/2005 13:20:00 7.8 0.6 9.1 5.7 7.5 0.6 8.8 5.7 227 4 233 305 9.1 0 9.7 8.9 07/27/2005 13:30:00 7.7 0.6 8.8 5.7 7.4 0.6 8.8 4.9 228 5 218 305 9.3 0.1 9.7 9.2 07/27/2005 13:40:00 7.4 0.7 8.8 5.3 7.1 0.8 8.8 4.9 226 5 227 305 9.6 0 10 9.5 07/27/2005 13:50:00 7.3 0.5 8.4 5.7 7 0.6 8.4 5.3 223 5 222 305 9.5 0 9.7 9.5 07/27/2005 14:00:00 6.6 0.7 8 4.9 6.3 0.7 7.6 4.2 230 6 226 305 9.5 0.1 9.7 9.2 07/27/2005 14:10:00 7.1 0.5 8 5.7 6.8 0.6 8 4.9 226 5 230 305 9.5 0.1 10 9.2 07/27/2005 14:20:00 7.2 0.6 8.4 5.3 6.8 0.6 8.4 5.3 231 7 231 305 9.7 0.2 10.2 9.2 07/27/2005 14:30:00 7.1 0.6 8.4 4.9 6.8 0.6 8.4 5.3 232 7 243 305 9.3 0.1 9.7 9.2 07/27/2005 14:40:00 7.1 0.6 8 5.3 6.8 0.6 8.4 5.3 232 6 222 305 9.3 0.1 9.7 9.2 07/27/2005 14:50:00 7.1 0.6 8.8 5.7 6.8 0.6 8.4 4.9 228 6 230 305 9.5 0.2 10 9.2 07/27/2005 15:00:00 7.4 0.5 8.4 5.7 7 0.6 8.4 5.3 223 5 225 305 9.7 0.1 10 9.5 07/27/2005 15:10:00 6.8 0.6 8.4 5.3 6.5 0.6 8 4.9 230 6 230 305 9.6 0 9.7 9.5 07/27/2005 15:20:00 6.6 0.6 8 4.9 6.2 0.7 7.6 4.6 235 7 235 305 9.9 0.1 10.2 9.7 07/27/2005 15:30:00 6.4 0.6 7.6 4.2 5.8 0.6 7.2 4.2 238 6 234 305 9.8 0 10 9.7 07/27/2005 15:40:00 6.6 0.7 8 4.6 6 0.7 7.6 3.8 237 6 242 305 9.8 0 10.2 9.7 07/27/2005 15:50:00 6.3 0.7 8 4.2 5.9 0.7 7.6 4.2 239 7 241 305 10.2 0 10.2 10 07/27/2005 16:00:00 5.8 0.5 7.2 4.6 5.5 0.6 7.2 4.2 236 6 236 305 9.9 0 10.2 9.7 07/27/2005 16:10:00 5.2 0.6 6.8 3.8 4.9 0.5 6.5 3.4 234 6 231 305 10.1 0 10.2 10 07/27/2005 16:20:00 4.8 0.5 6.1 3.4 4.6 0.5 5.7 3.4 233 8 240 305 10.3 0.2 10.8 10 07/27/2005 16:30:00 5.4 0.6 6.8 3.8 5.1 0.6 6.8 3 228 7 233 305 10.5 0 10.8 10.2 07/27/2005 16:40:00 5.1 0.6 6.5 3.4 4.9 0.6 6.5 3 215 7 223 305 10.5 0 10.8 10.2 07/27/2005 16:50:00 5 0.5 6.1 3.8 4.7 0.6 6.5 3 218 7 223 305 10.6 0 10.8 10.5 07/27/2005 17:00:00 5.5 0.5 6.5 3.8 5.3 0.5 6.5 3.8 221 6 217 305 10.5 0 10.8 10.2 07/27/2005 17:10:00 6.1 0.6 7.2 4.6 5.9 0.6 7.2 4.2 225 6 218 305 10.4 0 10.5 10.2 07/27/2005 17:20:00 5.5 0.5 6.8 3.8 5.2 0.6 6.5 3.8 227 7 234 305 10.4 0 10.5 10.2 07/27/2005 17:30:00 5.3 0.5 6.5 3.8 5.1 0.6 6.5 3.8 222 6 219 305 10.4 0 10.8 10.2 07/27/2005 17:40:00 5.7 0.6 7.2 4.2 5.4 0.6 6.8 3.8 226 6 222 305 10.6 0.1 10.8 10.5 07/27/2005 17:50:00 5.6 0.6 7.2 4.2 5.3 0.6 6.8 3.8 227 7 236 305 10.4 0 10.8 10.2 07/27/2005 18:00:00 5.7 0.5 6.8 4.2 5.5 0.6 6.5 3.8 224 5 222 305 10.4 0 10.5 10.2 07/27/2005 18:10:00 6.1 0.7 8.4 3.8 5.8 0.7 7.6 4.2 228 6 225 305 10.4 0 10.8 10.2 07/27/2005 18:20:00 6.4 0.7 8 4.6 6.2 0.7 7.6 4.6 228 7 227 305 10.4 0 10.5 10.2 07/27/2005 18:30:00 6.1 0.6 7.2 4.6 5.7 0.6 6.8 3.8 232 6 227 305 10.6 0 10.8 10.2 07/27/2005 18:40:00 6.3 0.7 7.6 4.2 6 0.7 7.6 4.2 227 6 228 305 10.4 0.2 10.8 10 07/27/2005 18:50:00 6.4 0.6 8 4.6 6.2 0.6 8 4.6 235 6 236 305 10.1 0 10.2 10 07/27/2005 19:00:00 6.7 0.5 8 5.3 6.5 0.5 7.6 4.6 229 5 222 305 10 0 10.2 10 07/27/2005 19:10:00 6.6 0.6 8 4.9 6.2 0.7 7.6 4.2 230 5 228 305 10.1 0 10.2 10 07/27/2005 19:20:00 6.2 0.8 8 4.2 5.8 0.8 7.6 4.2 233 8 236 305 10.4 0 10.8 10.2 07/27/2005 19:30:00 5.9 0.6 7.2 4.2 5.6 0.6 7.2 4.2 233 8 234 305 10.4 0 10.8 10.2 07/27/2005 19:40:00 5.9 0.7 8 3.8 5.5 0.7 7.2 3.8 233 6 227 305 10.4 0 10.5 10.2 07/27/2005 19:50:00 6.2 0.6 7.6 4.2 5.7 0.6 7.2 4.2 238 7 237 305 10.3 0 10.2 10.2 07/27/2005 20:00:00 6.9 0.8 8.4 4.9 6.5 0.8 8.4 4.6 231 7 234 305 10.2 0 10.2 10 07/27/2005 20:10:00 6.5 0.6 8 4.6 6.1 0.7 7.6 4.6 232 7 245 305 10.2 0 10.2 10 07/27/2005 20:20:00 6.3 0.6 8 4.9 5.9 0.8 7.6 4.2 232 7 241 305 10.1 0 10.2 10 07/27/2005 20:30:00 6.5 0.7 8 4.6 6 0.7 8.4 4.2 227 6 232 305 10 0 10.2 10 07/27/2005 20:40:00 5.6 0.6 7.2 3.8 5.2 0.7 7.2 3.8 226 6 228 305 10 0 10.2 10 07/27/2005 20:50:00 5.8 0.7 7.6 3.8 5.4 0.8 7.2 3.4 229 7 232 305 9.9 0 10.2 9.7 07/27/2005 21:00:00 6.4 0.6 8.4 4.6 6 0.7 7.6 4.2 228 6 224 305 9.7 0 10 9.7 07/27/2005 21:10:00 6.3 0.7 8 4.2 5.8 0.7 7.6 3.8 226 6 222 305 9.7 0 9.7 9.5 07/27/2005 21:20:00 5.7 0.7 7.6 3.4 5.4 0.7 6.8 3.8 225 6 230 305 9.6 0 9.7 9.5 07/27/2005 21:30:00 6 0.7 7.6 4.2 5.5 0.8 7.2 3.8 221 9 216 305 9.6 0 10 9.5 07/27/2005 21:40:00 6.8 0.7 8.4 4.9 6.3 0.7 8 4.2 224 8 221 305 9.5 0 9.7 9.2 07/27/2005 21:50:00 6.5 0.7 8 4.2 6.1 0.8 8 4.2 227 6 224 305 9.3 0 9.7 9.2 07/27/2005 22:00:00 5.9 0.7 8 4.2 5.5 0.8 7.6 3.8 228 9 238 305 9.4 0 9.7 9.2 07/27/2005 22:10:00 5.8 0.7 7.2 4.2 5.4 0.7 7.6 3.8 230 6 227 305 9.7 0 9.7 9.5 07/27/2005 22:20:00 5.9 0.7 7.6 4.2 5.6 0.6 7.6 3.8 229 5 229 305 9.7 0 10 9.5 07/27/2005 22:30:00 5.5 0.8 7.2 3.4 5.1 0.7 6.8 3.8 229 5 228 305 9.7 0 10 9.5 07/27/2005 22:40:00 5.8 0.7 7.2 3.8 5.4 0.7 7.2 3.8 228 6 229 305 9.7 0 10 9.5 07/27/2005 22:50:00 5.7 0.5 7.2 3.8 5.2 0.6 6.8 3.8 228 6 235 305 9.7 0 10 9.7 07/27/2005 23:00:00 6 0.6 7.2 4.2 5.6 0.6 7.2 4.2 225 6 223 305 9.7 0 10 9.7 07/27/2005 23:10:00 6 0.6 7.6 4.2 5.6 0.7 7.2 3.8 223 7 231 305 9.7 0 10 9.7 07/27/2005 23:20:00 5.9 0.7 7.6 4.2 5.4 0.7 7.6 3.4 214 8 229 305 9.7 0 10 9.5 07/27/2005 23:30:00 5.4 0.5 6.8 4.2 5.1 0.6 6.5 3 210 6 208 305 9.6 0 10 9.5 07/27/2005 23:40:00 5.4 0.6 6.8 3.4 5.1 0.6 6.5 3.4 212 6 218 305 9.6 0 10 9.5 07/27/2005 23:50:00 5.6 0.7 7.2 3.8 5.2 0.7 7.2 3 218 7 212 305 9.7 0 10.2 9.7 07/28/2005 00:00:00 5.5 0.7 7.2 3.8 5.2 0.7 6.8 3.4 214 5 215 305 9.7 0 10.2 9.5 07/28/2005 00:10:00 5.8 0.6 6.8 4.2 5.4 0.6 6.8 3.4 212 5 217 305 9.5 0 10 9.5 07/28/2005 00:20:00 5.8 0.5 7.2 4.2 5.5 0.6 6.8 3.4 212 6 213 305 9.5 0 10 9.5 07/28/2005 00:30:00 5.9 0.6 8 3.8 5.5 0.6 6.8 3.8 216 6 208 305 9.5 0 9.7 9.5 07/28/2005 00:40:00 5.7 0.6 7.6 4.2 5.3 0.7 7.6 3.4 213 7 219 305 9.7 0 10.2 9.5 07/28/2005 00:50:00 5.3 0.5 7.2 4.2 5.1 0.5 6.5 3 210 6 221 305 9.6 0 10.2 9.5 07/28/2005 01:00:00 5.8 0.6 7.2 4.2 5.5 0.6 6.8 4.2 211 7 218 305 9.7 0 10.2 9.5 07/28/2005 01:10:00 5.3 0.5 6.5 3.8 4.9 0.6 6.1 3.4 211 5 210 305 9.7 0 10.2 9.5 07/28/2005 01:20:00 5.6 0.5 6.5 4.2 5.2 0.6 6.5 3.4 211 5 213 305 9.6 0 10.2 9.5 07/28/2005 01:30:00 5.8 0.5 6.5 3.8 5.5 0.6 6.5 3.8 212 4 208 305 9.5 0 10 9.5 07/28/2005 01:40:00 5.7 0.4 6.8 4.6 5.5 0.5 6.5 3.8 210 4 214 305 9.5 0 10 9.5 07/28/2005 01:50:00 5.6 0.4 6.5 4.2 5.3 0.4 6.5 4.2 211 4 212 305 9.4 0 10 9.2 07/28/2005 02:00:00 5.6 0.4 6.8 4.2 5.4 0.5 6.8 4.2 211 5 205 305 9.4 0 10 9.5 07/28/2005 02:10:00 5.4 0.5 6.5 3.8 5.2 0.5 6.5 3.8 213 6 213 305 9.3 0.1 10 9.2 07/28/2005 02:20:00 5.5 0.7 7.2 3.4 5.1 0.7 6.8 3.4 220 7 217 305 9.5 0 10 9.2 07/28/2005 02:30:00 6.1 0.5 7.2 4.9 5.4 0.6 7.2 4.2 225 5 228 305 9.5 0 10 9.5 07/28/2005 02:40:00 5.9 0.5 6.8 4.6 5.4 0.6 6.8 3.8 226 4 227 305 9.5 0 10 9.5 07/28/2005 02:50:00 5.7 0.5 6.8 4.2 5.2 0.5 6.5 3.8 225 4 226 305 9.5 0 10 9.5 07/28/2005 03:00:00 5.5 0.5 6.8 3.8 5 0.5 6.5 3.8 225 4 227 305 9.5 0 10 9.5 07/28/2005 03:10:00 5.5 0.5 6.5 3.8 5 0.5 6.5 3.4 222 4 224 305 9.5 0 10 9.5 07/28/2005 03:20:00 5.6 0.6 6.8 4.2 5.1 0.7 6.5 3.4 223 5 220 305 9.5 0 10 9.5 07/28/2005 03:30:00 6.7 0.6 8.4 4.9 6.1 0.7 8 4.6 227 5 228 305 9.5 0 10 9.5 07/28/2005 03:40:00 6.2 0.6 7.6 4.6 5.7 0.6 6.8 4.2 228 5 226 305 9.5 0 10 9.5 07/28/2005 03:50:00 5.8 0.5 7.2 4.2 5.3 0.6 6.8 3.8 232 4 232 305 9.4 0.1 10 9.2 07/28/2005 04:00:00 6 0.6 7.2 4.2 5.4 0.6 6.8 3.8 224 6 220 305 9.4 0 9.7 9.2 07/28/2005 04:10:00 5.7 0.7 6.8 3.8 5.4 0.7 6.5 3.4 229 6 221 305 9.3 0 9.5 9.2 07/28/2005 04:20:00 5.5 0.5 6.5 3.8 5 0.5 6.1 3.4 230 5 230 305 9.3 0 9.5 9.2 07/28/2005 04:30:00 6 0.6 8 4.2 5.5 0.6 7.2 3.8 232 5 234 305 9.2 0 9.5 9.2 07/28/2005 04:40:00 5.2 0.5 6.5 3.4 4.9 0.5 6.1 3 224 4 225 305 9.3 0 9.7 9.2 07/28/2005 04:50:00 5.4 0.6 6.8 3.8 4.9 0.6 6.5 3.4 225 5 228 305 9.4 0 9.7 9.2 07/28/2005 05:00:00 4.9 0.5 6.5 3.8 4.6 0.5 6.1 3 227 8 224 305 9.6 0 9.7 9.5 07/28/2005 05:10:00 4.6 0.4 5.3 3.4 4.3 0.4 5.3 2.6 224 5 232 305 9.5 0 9.7 9.5 07/28/2005 05:20:00 4.5 0.4 5.7 3.4 4.1 0.4 5.3 3 224 4 218 305 9.5 0 9.7 9.5 07/28/2005 05:30:00 4.3 0.5 5.3 3 4.1 0.5 4.9 3 213 5 214 305 9.5 0 9.7 9.5 07/28/2005 05:40:00 4.5 0.3 5.3 2.6 4.4 0.4 5.3 2.6 208 5 213 305 9.4 0 9.7 9.2 07/28/2005 05:50:00 5 0.7 6.5 3 4.6 0.7 6.1 3 220 7 222 305 9.5 0 9.7 9.5 07/28/2005 06:00:00 5.5 0.6 7.6 3.8 5 0.6 7.2 3.4 224 5 228 305 9.6 0 9.7 9.5 07/28/2005 06:10:00 6.2 0.5 7.2 4.6 5.8 0.6 7.2 3.8 227 5 221 305 9.5 0 10.2 9.5 07/28/2005 06:20:00 6.5 0.5 7.6 4.9 6 0.7 7.2 4.2 226 4 224 305 9.5 0 9.7 9.5 07/28/2005 06:30:00 5.8 0.5 6.8 3.8 5.4 0.5 6.5 3.8 228 5 228 305 9.7 0 9.7 9.5 07/28/2005 06:40:00 5.9 0.5 6.8 4.2 5.5 0.6 6.8 3.8 230 4 227 305 9.6 0 10.2 9.5 07/28/2005 06:50:00 5.3 0.4 6.5 4.2 5 0.5 6.1 3.4 225 6 229 305 9.6 0 10.2 9.5 07/28/2005 07:00:00 5.5 0.5 6.8 3.8 5 0.5 6.5 3.8 223 6 223 305 9.7 0 10.2 9.5 07/28/2005 07:10:00 5.6 0.4 6.8 4.2 5.2 0.5 6.5 3.8 227 6 227 305 9.7 0 10.2 9.5 07/28/2005 07:20:00 5.2 0.7 6.8 3.8 4.8 0.7 6.8 3.4 225 6 224 305 9.7 0 10.2 9.5 07/28/2005 07:30:00 6.1 0.5 7.2 4.2 5.6 0.6 6.5 3.8 229 7 224 305 9.6 0 10.2 9.5 07/28/2005 07:40:00 5.9 0.5 7.2 4.6 5.4 0.6 6.8 3.8 236 4 237 305 9.5 0 10 9.5 07/28/2005 07:50:00 5.8 0.6 7.6 4.2 5.4 0.7 7.6 3.8 232 6 229 305 9.5 0 10 9.5 07/28/2005 08:00:00 5.8 0.5 6.8 4.2 5.3 0.6 6.5 3.8 221 5 213 305 9.6 0 10 9.5 07/28/2005 08:10:00 5.5 0.6 7.2 4.2 5.1 0.7 6.8 3.8 224 5 230 305 9.7 0 10 9.7 07/28/2005 08:20:00 5.7 0.5 6.8 3.8 5.3 0.6 6.8 3.8 225 7 234 305 9.7 0 9.7 9.7 07/28/2005 08:30:00 5.8 0.5 6.8 4.2 5.4 0.6 6.5 4.2 229 5 227 305 9.7 0 10 9.5 07/28/2005 08:40:00 5.1 0.8 6.8 3.4 4.7 0.8 7.2 3 229 10 246 305 9.7 0 10 9.5 07/28/2005 08:50:00 5.1 0.5 6.5 3.8 4.8 0.5 6.5 3.4 223 5 223 305 9.7 0 10.2 9.5 07/28/2005 09:00:00 5.4 0.4 6.5 4.2 5 0.5 6.1 3.4 222 5 221 305 9.7 0 9.7 9.5 07/28/2005 09:10:00 5.4 0.5 6.8 3.8 5 0.5 6.1 3.4 222 8 219 305 9.8 0 10.5 9.7 07/28/2005 09:20:00 5.2 0.4 6.1 3.8 4.8 0.5 6.1 3.4 222 5 225 305 9.8 0 10.2 9.7 07/28/2005 09:30:00 4.5 0.5 5.7 3.4 4.1 0.5 5.3 3 235 11 230 305 9.8 0 10.2 9.7 07/28/2005 09:40:00 3.6 0.5 5.3 2.3 3.4 0.5 4.9 2.3 236 7 238 305 10.2 0 10.5 10 07/28/2005 09:50:00 4.2 0.5 5.3 3 4 0.5 4.9 2.6 223 6 226 305 10.1 0 10.5 10 07/28/2005 10:00:00 4.7 0.5 5.7 3.4 4.4 0.6 5.7 3 213 5 217 305 9.9 0 10.2 9.7 07/28/2005 10:10:00 5 0.5 6.1 3.4 4.6 0.6 6.1 3.4 213 5 212 305 9.9 0 10.2 9.7 07/28/2005 10:20:00 5.4 0.5 6.5 3.8 5.1 0.6 6.5 3.4 213 5 208 305 10 0 10.2 10 07/28/2005 10:30:00 6.1 0.4 7.2 4.6 5.7 0.6 7.2 4.2 214 5 206 305 10 0 10.2 10 07/28/2005 10:40:00 6.2 0.4 7.2 4.2 5.8 0.5 6.8 4.6 214 4 206 305 10.2 0 10.2 10 07/28/2005 10:50:00 6.1 0.5 7.2 4.6 5.7 0.6 7.2 3.8 218 5 213 305 10.1 0 10.2 10 07/28/2005 11:00:00 5.5 0.7 6.8 3.8 5.1 0.7 6.8 3.4 223 5 211 305 10.2 0 10.2 10 07/28/2005 11:10:00 6 0.5 7.2 4.6 5.6 0.6 6.8 3.8 230 5 218 305 10.2 0 10.2 10 07/28/2005 11:20:00 5.8 0.7 7.2 4.2 5.3 0.7 6.8 3.8 236 5 235 305 10.2 0 10.2 10 07/28/2005 11:30:00 6 0.5 7.2 4.2 5.3 0.6 6.8 4.2 237 5 236 305 10.2 0 10.5 10 07/28/2005 11:40:00 6.1 0.5 7.2 4.6 5.4 0.5 6.8 3.8 239 5 238 305 10.4 0 10.5 10.2 07/28/2005 11:50:00 6.2 0.5 7.2 4.6 5.6 0.6 6.8 4.2 237 4 235 305 10.5 0 10.8 10.2 07/28/2005 12:00:00 6.1 0.5 7.2 4.6 5.6 0.6 7.2 4.2 233 5 234 305 10.6 0 10.8 10.2 07/28/2005 12:10:00 5.9 0.5 6.8 4.2 5.5 0.6 6.8 4.2 228 5 228 305 10.6 0 10.8 10.5 07/28/2005 12:20:00 5.5 0.6 6.8 3.8 5.2 0.6 6.5 3.8 227 6 231 305 10.9 0.1 11 10.5 07/28/2005 12:30:00 6.1 0.6 7.6 4.6 5.8 0.6 6.8 4.2 231 5 237 305 10.9 0 11 10.5 07/28/2005 12:40:00 6.6 0.4 7.6 4.9 6.3 0.5 7.6 4.6 232 5 231 305 10.5 0.1 10.8 10.2 07/28/2005 12:50:00 6 0.6 7.2 4.2 5.6 0.6 6.8 3.8 235 6 236 305 10.4 0 10.5 10.2 07/28/2005 13:00:00 6.2 0.6 7.6 4.6 5.8 0.7 7.2 3.8 241 5 233 305 10.4 0.1 10.8 10.2 07/28/2005 13:10:00 6.2 0.6 7.2 4.6 5.8 0.6 7.2 4.2 241 7 234 305 10.5 0 10.8 10.2 07/28/2005 13:20:00 5.8 0.7 7.2 4.2 5.4 0.6 6.8 3.8 240 6 243 305 10.6 0 10.8 10.2 07/28/2005 13:30:00 6.1 0.7 7.6 4.2 5.7 0.7 7.2 4.2 242 7 241 305 10.9 0 11 10.5 07/28/2005 13:40:00 6.1 0.7 8 4.2 5.8 0.7 8 3.8 237 7 242 305 10.9 0 11 10.8 07/28/2005 13:50:00 5.8 0.7 7.6 4.2 5.6 0.7 7.2 3.8 232 8 243 305 11.2 0 11.3 11 07/28/2005 14:00:00 6.3 0.7 8 4.6 6 0.7 8.4 3.8 242 6 246 305 11 0.2 11.3 10.8 07/28/2005 14:10:00 6.5 0.6 7.6 4.6 6.2 0.7 7.6 4.2 238 8 234 305 10.8 0 11 10.8 07/28/2005 14:20:00 6.1 0.6 7.2 4.6 5.7 0.6 7.2 3.8 235 7 238 305 10.9 0 11.3 10.8 07/28/2005 14:30:00 6 0.6 7.6 4.2 5.7 0.6 7.2 4.2 234 7 230 305 11 0.1 11.3 10.8 07/28/2005 14:40:00 6.1 0.7 8 4.2 5.7 0.6 7.6 4.2 234 7 234 305 10.8 0 11 10.5 07/28/2005 14:50:00 6.8 0.7 8 4.9 6.5 0.6 8 4.6 233 6 232 305 11 0 11.3 10.8 07/28/2005 15:00:00 6.9 0.7 8.4 4.6 6.5 0.8 8.4 4.2 239 7 239 305 10.9 0 11 10.5 07/28/2005 15:10:00 7.1 0.8 9.1 4.9 6.9 0.8 8.4 4.6 244 6 242 305 10.7 0.1 11 10.5 07/28/2005 15:20:00 7 0.7 8.8 5.3 6.6 0.8 8.8 4.2 240 8 250 305 10.8 0 11 10.5 07/28/2005 15:30:00 7.2 0.7 8.8 4.9 6.6 0.8 8.4 4.2 239 6 242 305 11 0.2 11.3 10.8 07/28/2005 15:40:00 6.9 0.9 8.4 4.6 6.5 0.9 8.4 4.2 243 7 239 305 11 0.1 11.6 10.8 07/28/2005 15:50:00 7.3 0.8 9.1 4.9 6.9 0.8 8.8 4.9 244 8 252 305 10.8 0 11 10.8 07/28/2005 16:00:00 6.8 0.7 8.4 4.9 6.4 0.8 8.4 4.2 241 6 237 305 10.8 0 11 10.5 07/28/2005 16:10:00 6.1 0.7 8 3.8 5.9 0.8 7.6 3.4 248 7 246 305 10.8 0 11 10.8 07/28/2005 16:20:00 6.3 0.8 8 4.2 6 0.9 8.4 3.4 244 7 245 305 10.9 0 11 10.8 07/28/2005 16:30:00 6.2 0.7 7.6 4.6 5.9 0.7 7.6 3.8 243 7 253 305 11 0 11.3 10.8 07/28/2005 16:40:00 6.4 0.8 8 4.2 6.1 0.8 7.6 3.8 235 6 234 305 11.1 0.1 11.3 10.8 07/28/2005 16:50:00 6.6 0.7 8.4 4.6 6.3 0.7 8 4.6 232 6 234 305 10.9 0 11.3 10.8 07/28/2005 17:00:00 7 0.6 8.8 5.3 6.7 0.7 8.8 4.6 231 5 236 305 10.9 0 11 10.8 07/28/2005 17:10:00 6.8 0.8 8.4 5.3 6.4 0.8 8.4 4.6 235 8 232 305 10.9 0 11 10.8 07/28/2005 17:20:00 7 0.8 8.8 4.9 6.5 0.8 8.8 4.6 239 7 234 305 11 0 11.3 10.8 07/28/2005 17:30:00 7 0.6 8.4 4.9 6.4 0.7 8 4.6 236 5 231 305 10.9 0 11 10.8 07/28/2005 17:40:00 7 0.8 8.8 4.9 6.2 0.8 8 4.2 237 6 239 305 10.8 0 11 10.5 07/28/2005 17:50:00 7.7 0.6 9.1 5.7 7.1 0.7 9.1 5.3 239 5 242 305 10.7 0 11 10.5 07/28/2005 18:00:00 7.4 0.7 9.1 5.3 6.9 0.7 8.4 4.6 244 6 239 305 10.4 0.1 10.8 10.2 07/28/2005 18:10:00 7.3 0.6 8.8 5.3 6.9 0.7 8.4 4.6 236 6 243 305 10.4 0.1 10.8 10.2 07/28/2005 18:20:00 7.7 0.8 9.5 5.3 7.3 0.9 9.5 4.9 242 7 236 305 10.2 0 10.5 10 07/28/2005 18:30:00 7.3 0.9 9.5 5.3 6.8 0.9 8.8 4.9 242 7 233 305 10.2 0 10.2 10 07/28/2005 18:40:00 7.3 0.8 9.1 4.9 6.8 0.8 8.8 4.9 239 8 245 305 10.2 0 10.5 10.2 07/28/2005 18:50:00 7.4 1 9.1 5.3 6.9 1 9.1 4.6 242 8 227 305 10.2 0 10.5 10 07/28/2005 19:00:00 7.1 0.8 8.8 4.9 6.7 0.8 8.4 4.6 243 7 241 305 10.2 0 10.2 10 07/28/2005 19:10:00 7.7 0.7 9.1 5.7 7.3 0.7 8.8 5.3 233 5 236 305 9.9 0 10.2 9.7 07/28/2005 19:20:00 7 0.8 8.8 5.3 6.6 0.8 8.8 4.6 240 5 238 305 9.7 0 10 9.5 07/28/2005 19:30:00 7.6 0.8 9.1 4.9 7.1 0.9 8.8 4.6 238 6 232 305 9.7 0 9.7 9.5 07/28/2005 19:40:00 7.3 0.7 9.1 4.6 6.9 0.8 8.8 4.6 234 8 229 305 9.5 0 9.7 9.2 07/28/2005 19:50:00 7.9 0.8 9.5 5.7 7.4 0.8 9.1 5.3 234 6 235 305 9.4 0 9.7 9.2 07/28/2005 20:00:00 8.3 0.9 9.9 5.7 7.7 0.9 9.5 5.3 238 5 239 305 9.5 0 9.7 9.2 07/28/2005 20:10:00 8.2 0.7 9.9 6.1 7.6 0.8 9.5 5.3 235 5 232 305 9.1 0 9.5 9.2 07/28/2005 20:20:00 8.6 0.6 10.3 6.5 7.9 0.8 9.5 5.7 238 4 242 305 9.2 0 9.7 9.2 07/28/2005 20:30:00 8.3 0.6 9.5 6.5 7.8 0.8 9.1 5.7 233 5 235 305 9.2 0 9.5 9.2 07/28/2005 20:40:00 8.7 0.6 10.3 6.8 8.1 0.7 9.5 6.1 236 5 230 305 9.2 0 9.2 9.2 07/28/2005 20:50:00 8.7 0.7 10.3 6.5 8 0.8 10.3 5.7 233 6 230 305 9.1 0 9.7 8.9 07/28/2005 21:00:00 8.2 0.7 9.9 6.5 7.6 0.8 9.5 5.7 235 5 238 305 9.1 0 9.7 9.2 07/28/2005 21:10:00 8.8 0.6 10.3 7.2 8.2 0.7 9.9 6.1 236 5 245 305 9.2 0 9.7 9.2 07/28/2005 21:20:00 7.9 0.8 9.5 5.7 7.4 0.8 9.1 4.9 235 6 233 305 9.1 0 9.7 8.9 07/28/2005 21:30:00 8.6 0.8 10.3 6.1 8 0.9 9.9 5.7 232 6 221 305 9.2 0 9.7 9.2 07/28/2005 21:40:00 8.7 0.8 10.3 5.7 8.1 1 10.3 5.3 234 8 234 305 9 0 9.5 8.9 07/28/2005 21:50:00 8.2 1 9.9 5.3 7.6 1 9.9 5.3 240 6 242 305 8.9 0.1 9.5 8.7 07/28/2005 22:00:00 8 0.7 9.5 5.7 7.5 0.8 9.5 5.7 232 6 227 305 8.9 0 9.2 8.9 07/28/2005 22:10:00 8.3 0.7 9.9 6.5 7.5 0.8 9.5 5.7 236 7 255 305 8.9 0.1 9.5 8.7 07/28/2005 22:20:00 7.9 0.8 9.5 6.1 7.1 0.9 9.5 4.6 241 6 239 305 8.8 0 9.2 8.9 07/28/2005 22:30:00 8.3 0.7 9.9 6.1 7.6 0.9 9.9 5.3 238 6 237 305 8.6 0 8.9 8.4 07/28/2005 22:40:00 8.4 0.9 9.9 5.7 7.7 1 9.5 5.3 241 6 245 305 8.6 0 8.7 8.4 07/28/2005 22:50:00 8.4 0.9 10.3 5.7 7.7 0.9 9.9 4.9 237 6 243 305 8.5 0 8.9 8.4 07/28/2005 23:00:00 8.4 0.6 9.9 6.8 7.7 0.8 9.5 5.3 236 6 238 305 8.6 0 8.7 8.4 07/28/2005 23:10:00 7.9 0.7 9.1 5.7 7.3 0.8 8.8 4.6 238 7 242 305 8.4 0 8.7 8.4 07/28/2005 23:20:00 7.8 0.7 9.1 5.7 7.1 0.8 9.1 4.9 244 9 246 305 8.4 0.2 8.7 8.2 07/28/2005 23:30:00 7.9 0.8 9.9 5.7 7.3 0.8 9.1 4.2 245 6 242 305 8.3 0 8.4 8.2 07/28/2005 23:40:00 8 0.9 10.3 5.7 7.4 1 9.1 4.9 236 6 228 305 8.4 0 8.4 8.2 07/28/2005 23:50:00 8.2 0.7 9.5 6.5 7.7 0.8 9.5 5.7 235 9 236 305 8.4 0 8.7 8.2 07/29/2005 00:00:00 7.6 0.9 9.9 5.7 6.8 1 9.1 4.6 241 8 251 305 8.4 0 8.9 8.2 07/29/2005 00:10:00 8.5 0.7 10.3 6.5 7.7 0.9 9.9 4.9 248 6 237 305 8.3 0 8.4 8.2 07/29/2005 00:20:00 8.4 0.7 9.9 6.1 7.6 1 9.9 5.3 239 6 224 305 8.3 0 8.4 8.2 07/29/2005 00:30:00 8.2 0.8 10.3 6.1 7.6 0.9 9.5 5.3 234 5 231 305 8.2 0 8.4 8.2 07/29/2005 00:40:00 8.6 0.6 9.9 6.1 8.2 0.6 9.9 6.5 232 4 229 305 8.3 0 8.4 8.2 07/29/2005 00:50:00 8.3 0.8 9.9 6.1 7.8 0.8 9.9 5.7 233 5 236 305 8.2 0.1 8.9 8.2 07/29/2005 01:00:00 8.2 0.8 10.3 6.1 7.5 0.8 9.9 5.3 238 7 235 305 8.4 0.1 8.9 8.2 07/29/2005 01:10:00 8.9 0.7 10.3 6.1 8.2 0.8 10.3 5.3 237 5 231 305 8.2 0.1 8.7 7.9 07/29/2005 01:20:00 8.6 0.9 10.7 6.1 8 0.9 9.5 5.7 241 7 234 305 8.2 0.1 8.7 7.9 07/29/2005 01:30:00 8.8 0.8 10.3 6.1 8.2 0.9 10.3 5.7 236 5 234 305 8.2 0.1 8.7 8.2 07/29/2005 01:40:00 8.3 0.8 11.1 6.5 7.5 0.8 9.9 5.7 241 7 238 305 8.2 0.2 8.9 8.2 07/29/2005 01:50:00 9.5 0.7 11.1 7.6 8.7 0.9 10.7 6.1 246 4 242 305 8.1 0 8.7 7.9 07/29/2005 02:00:00 8.3 1 9.9 5.7 7.5 1.1 9.9 4.9 246 6 251 305 8.2 0.1 8.9 7.9 07/29/2005 02:10:00 8.3 0.8 10.3 6.1 7.7 0.9 9.9 5.3 242 8 246 305 8.1 0.1 8.7 7.9 07/29/2005 02:20:00 8.1 1 9.9 5.7 7.3 1.1 9.5 4.6 244 6 243 305 8.2 0.1 8.9 8.2 07/29/2005 02:30:00 8.4 1 10.3 5.7 7.5 1.1 9.9 4.9 243 7 245 305 8.3 0.1 8.9 8.2 07/29/2005 02:40:00 8.3 1 10.3 5.3 7.6 1 9.5 4.6 241 8 235 305 8.4 0.1 8.9 8.2 07/29/2005 02:50:00 8.4 0.9 10.3 5.3 7.7 0.9 9.9 4.6 243 9 241 305 8.4 0.1 9.2 8.2 07/29/2005 03:00:00 8.5 0.8 9.9 6.1 7.8 1 9.9 4.9 243 7 241 305 8.2 0.1 8.9 7.9 07/29/2005 03:10:00 7.8 0.8 9.5 5.3 7.2 0.9 8.8 4.6 243 5 242 305 8.1 0.1 8.9 7.9 07/29/2005 03:20:00 7.7 0.9 9.5 4.9 7.1 0.9 9.1 4.9 244 8 239 305 8.3 0.1 8.9 8.2 07/29/2005 03:30:00 7.8 0.8 9.5 5.3 7.2 0.9 9.5 4.6 240 5 234 305 8.4 0.1 8.9 8.2 07/29/2005 03:40:00 7 0.8 8.8 4.9 6.3 0.9 8.4 3.8 244 8 238 305 8.4 0 9.2 8.2 07/29/2005 03:50:00 8.1 0.8 9.5 4.9 7.2 1 9.1 4.6 251 6 252 305 8.2 0.1 8.9 8.2 07/29/2005 04:00:00 7.8 0.7 9.5 5.7 7.2 0.7 8.8 5.3 236 5 234 305 8.2 0 8.4 8.2 07/29/2005 04:10:00 7.9 0.6 9.1 5.7 7.2 0.8 8.8 4.9 240 6 239 305 8.4 0 8.4 8.2 07/29/2005 04:20:00 7.8 0.6 9.5 5.3 7.1 0.7 9.1 5.3 238 5 236 305 8.4 0 8.4 8.2 07/29/2005 04:30:00 8 0.9 9.9 5.7 7.4 1 9.5 4.9 242 7 242 305 8.4 0 8.4 8.2 07/29/2005 04:40:00 7.7 1 9.5 5.3 7.2 1 9.9 4.9 239 8 251 305 8.4 0 8.4 8.2 07/29/2005 04:50:00 7.7 0.8 9.9 5.3 6.9 1 9.1 4.6 252 5 250 305 8.2 0 8.4 8.2 07/29/2005 05:00:00 7.5 1 9.9 4.2 6.9 1 9.5 4.6 246 7 256 305 8.3 0 8.9 8.2 07/29/2005 05:10:00 7.8 0.8 9.1 5.3 7.1 1 9.1 4.2 249 6 250 305 8.2 0 8.9 8.2 07/29/2005 05:20:00 7.9 0.8 9.5 5.3 7.3 1 9.1 4.6 238 9 255 305 8.4 0 8.9 8.2 07/29/2005 05:30:00 7.5 0.8 9.1 4.9 6.7 1 8.8 4.2 247 11 256 305 8.4 0.1 8.9 8.2 07/29/2005 05:40:00 8 0.8 9.9 5.7 7.3 1 9.5 3.8 245 6 242 305 8.3 0.2 8.9 8.2 07/29/2005 05:50:00 7.7 0.7 9.9 5.3 7 0.9 9.1 4.2 241 6 239 305 8.4 0.1 8.9 8.2 07/29/2005 06:00:00 7.3 0.7 8.8 5.3 6.6 0.7 8 4.6 241 6 238 305 8.4 0.1 8.9 8.2 07/29/2005 06:10:00 7 0.8 8.8 4.6 6.3 1 8 3.4 247 8 247 305 8.4 0.1 8.9 8.2 07/29/2005 06:20:00 7 0.9 9.1 4.9 6.3 1.1 8.8 3.8 246 8 252 305 8.2 0.1 8.9 8.2 07/29/2005 06:30:00 6.9 1 9.1 4.6 6 1.2 8.8 3 252 7 249 305 8 0 8.7 7.9 07/29/2005 06:40:00 7.6 0.7 9.1 5.3 6.9 0.8 8.4 4.2 243 5 246 305 8 0 8.4 7.9 07/29/2005 06:50:00 6.8 0.8 8.8 4.9 6.3 0.7 8 4.2 238 6 245 305 8.1 0 8.7 7.9 07/29/2005 07:00:00 7.3 0.9 9.1 5.3 6.6 1 9.1 4.2 242 6 240 305 8.2 0 8.9 7.9 07/29/2005 07:10:00 7.2 0.8 8.8 4.9 6.4 0.8 8 4.2 242 6 251 305 8.1 0 8.7 7.9 07/29/2005 07:20:00 7.3 0.6 8.4 5.3 6.5 0.8 8 3.4 245 5 234 305 8.2 0.1 8.9 8.2 07/29/2005 07:30:00 6.7 0.7 8.4 4.6 5.9 0.7 7.6 4.2 237 6 242 305 8.4 0 9.2 8.2 07/29/2005 07:40:00 7.4 0.9 8.8 4.6 6.7 1 8.8 3.4 244 6 254 305 8.3 0.1 9.2 8.2 07/29/2005 07:50:00 7.4 1 9.5 5.3 6.7 1.1 8.8 4.2 242 5 242 305 8.4 0 8.9 8.2 07/29/2005 08:00:00 7.3 0.8 8.8 4.2 6.5 0.8 8.4 4.2 238 6 241 305 8.5 0 8.7 8.2 07/29/2005 08:10:00 7.3 0.7 9.1 4.9 6.7 0.8 8.8 4.6 236 6 227 305 8.6 0 8.7 8.4 07/29/2005 08:20:00 6.8 0.8 8.4 4.6 6.2 0.8 8 3.4 235 8 246 305 8.6 0 8.9 8.4 07/29/2005 08:30:00 7.1 0.6 8.4 4.9 6.5 0.8 8.4 3.8 232 5 241 305 8.6 0 8.9 8.4 07/29/2005 08:40:00 7.4 0.7 8.8 5.3 6.7 0.8 8.8 4.6 238 6 238 305 8.6 0 8.9 8.4 07/29/2005 08:50:00 7 0.6 8.4 4.9 6.5 0.7 8 4.6 240 6 241 305 8.6 0 8.9 8.4 07/29/2005 09:00:00 7.1 0.8 8.4 4.6 6.6 0.7 8 4.6 238 5 228 305 8.6 0 9.2 8.4 07/29/2005 09:10:00 7.5 0.7 8.8 5.3 7 0.7 8.4 4.9 237 5 238 305 8.8 0 9.2 8.7 07/29/2005 09:20:00 8 0.8 9.9 6.1 7.3 0.9 9.5 5.3 233 5 232 305 8.9 0 9.2 8.9 07/29/2005 09:30:00 8 0.6 9.1 6.1 7.3 0.7 9.1 4.9 232 6 234 305 8.9 0 9.2 8.9 07/29/2005 09:40:00 7.1 0.8 8.8 4.6 6.6 0.8 8.8 4.6 227 6 231 305 9.1 0 9.5 8.9 07/29/2005 09:50:00 7.4 0.6 8.8 5.7 6.9 0.7 8.4 4.9 227 5 227 305 9.2 0 9.2 9.2 07/29/2005 10:00:00 7 0.6 8.8 5.3 6.5 0.8 8.4 4.6 231 6 241 305 9.2 0.1 9.7 8.7 07/29/2005 10:10:00 7 0.5 8.4 5.3 6.2 0.6 7.6 4.6 230 6 231 305 9.3 0.1 10 9.2 07/29/2005 10:20:00 7.7 0.6 9.1 5.3 7.1 0.7 8.4 4.9 233 5 230 305 9.4 0.1 10 9.2 07/29/2005 10:30:00 7.5 0.7 8.8 5.3 6.7 0.7 8.4 4.2 235 4 237 305 9.6 0 10.2 9.5 07/29/2005 10:40:00 7.3 0.6 8.8 5.3 6.7 0.6 8 5.3 234 5 232 305 9.6 0 10.2 9.5 07/29/2005 10:50:00 7.1 0.7 8.8 4.9 6.4 0.8 8 4.2 236 6 234 305 9.8 0 10.2 9.5 07/29/2005 11:00:00 7.3 0.6 8.8 4.9 6.7 0.7 8.4 4.6 235 4 238 305 9.8 0 10.2 9.7 07/29/2005 11:10:00 6.7 0.7 8 4.6 6.2 0.7 8 4.6 237 5 239 305 9.6 0 9.7 9.2 07/29/2005 11:20:00 6.7 0.7 8.4 4.6 6.3 0.8 8.4 4.6 233 6 231 305 9.7 0 9.7 9.5 07/29/2005 11:30:00 6.9 0.8 8.4 4.9 6.4 0.8 8.4 4.6 237 6 236 305 9.9 0.1 10.2 9.5 07/29/2005 11:40:00 7 0.8 8.8 4.9 6.4 0.9 8.4 4.6 234 6 233 305 9.9 0 10.2 9.7 07/29/2005 11:50:00 7.2 0.7 8.8 5.3 6.6 0.7 8 4.9 236 5 234 305 10 0 10.2 9.7 07/29/2005 12:00:00 6.9 0.5 8 5.7 6.5 0.6 8 4.9 233 5 235 305 10 0 10.2 9.7 07/29/2005 12:10:00 6.4 0.6 8.4 4.9 6.1 0.6 8.4 4.2 230 6 230 305 10.2 0 10.2 10 07/29/2005 12:20:00 6.4 0.5 8 5.3 6 0.6 8 4.2 229 6 233 305 10.2 0 10.2 10 07/29/2005 12:30:00 6.4 0.7 8 4.6 6 0.7 8 4.6 228 6 231 305 10.4 0.1 10.8 10.2 07/29/2005 12:40:00 6.7 0.6 8 4.9 6.3 0.7 7.6 4.6 228 6 223 305 10.7 0.1 11 10.2 07/29/2005 12:50:00 6.7 0.7 8.8 4.9 6.3 0.7 8 4.6 236 8 248 305 10.7 0 11 10.5 07/29/2005 13:00:00 6.4 0.6 7.6 4.9 6 0.6 8 4.6 237 7 238 305 10.9 0 11 10.8 07/29/2005 13:10:00 6.5 0.6 8 4.6 6.2 0.7 7.6 4.6 225 7 212 305 11 0 11.3 10.8 07/29/2005 13:20:00 6.6 0.6 7.6 4.9 6.4 0.6 7.6 4.6 219 5 219 305 10.8 0 11.3 10.8 07/29/2005 13:30:00 7 0.6 8 5.3 6.7 0.7 8 4.6 221 5 211 305 11 0.1 11.3 10.8 07/29/2005 13:40:00 7 0.7 8.4 4.9 6.8 0.7 8 4.9 220 5 217 305 11 0 11.3 10.8 07/29/2005 13:50:00 7.4 0.5 8.4 5.7 7 0.6 8 5.3 220 5 218 305 11.2 0 11.3 11 07/29/2005 14:00:00 7.1 0.6 8 5.3 6.7 0.7 8 4.9 220 5 224 305 11.1 0 11.3 10.8 07/29/2005 14:10:00 7.1 0.5 8.4 5.7 6.8 0.6 8.4 4.9 220 5 223 305 11 0.1 11.3 10.8 07/29/2005 14:20:00 7.1 0.5 8.4 5.7 6.7 0.7 8 4.6 222 5 225 305 11 0 11.3 10.8 07/29/2005 14:30:00 6.9 0.7 8.4 4.6 6.5 0.7 8 4.9 226 5 234 305 11 0 11 10.8 07/29/2005 14:40:00 6.8 0.7 8 4.9 6.3 0.7 8 4.6 227 5 227 305 11 0 11.3 10.5 07/29/2005 14:50:00 7.1 0.6 8.8 5.3 6.7 0.7 8 4.6 228 5 225 305 10.8 0 11 10.5 07/29/2005 15:00:00 7 0.7 8.4 5.3 6.5 0.8 8.4 4.6 228 6 230 305 10.8 0 11 10.5 07/29/2005 15:10:00 7.4 0.6 8.8 4.6 7 0.6 8.4 5.3 231 6 226 305 10.6 0.1 10.8 10.2 07/29/2005 15:20:00 7.3 0.8 9.1 5.3 6.9 0.8 9.1 4.9 238 6 241 305 10.4 0 10.8 10.2 07/29/2005 15:30:00 7.8 0.8 9.5 5.7 7.3 0.8 9.1 5.3 240 6 240 305 10.6 0.2 11 10.2 07/29/2005 15:40:00 7.3 0.8 8.8 5.3 6.7 0.9 8.4 4.2 239 5 245 305 10.7 0 11 10.5 07/29/2005 15:50:00 7.6 0.8 9.5 5.3 7.1 0.8 9.1 5.3 240 7 232 305 10.6 0 10.8 10.2 07/29/2005 16:00:00 7.8 0.7 9.5 5.7 7.4 0.8 9.1 4.9 238 5 233 305 10.5 0 10.8 10.2 07/29/2005 16:10:00 7.7 0.7 9.1 5.3 7.2 0.7 8.8 4.6 238 5 231 305 10.6 0 10.8 10.2 07/29/2005 16:20:00 8 0.8 9.5 6.1 7.5 0.8 9.1 5.3 234 5 241 305 10.4 0 10.5 10.2 07/29/2005 16:30:00 7.8 0.7 9.5 5.3 7.4 0.7 9.1 5.3 237 7 234 305 10.3 0 10.5 10 07/29/2005 16:40:00 7.8 0.8 9.1 5.7 7.3 0.9 8.8 4.9 243 6 234 305 10.3 0 10.5 10.2 07/29/2005 16:50:00 7.1 0.6 9.1 5.3 6.7 0.6 8.8 4.6 237 7 223 305 10.3 0 10.5 10.2 07/29/2005 17:00:00 7.5 0.6 8.8 5.7 7.1 0.6 8.8 5.3 234 6 237 305 10.2 0 10.5 10 07/29/2005 17:10:00 7.3 0.7 9.1 5.3 6.9 0.8 8.8 4.9 239 6 236 305 10.2 0 10.5 10 07/29/2005 17:20:00 7.3 0.7 8.8 5.3 6.9 0.7 8.4 4.9 238 6 240 305 10.2 0 10.2 10 07/29/2005 17:30:00 6.4 0.7 8 4.2 6 0.9 7.6 3.8 247 8 252 305 10.1 0 10.2 10 07/29/2005 17:40:00 6.8 0.8 8.4 4.6 6.4 0.8 8.4 4.6 241 6 243 305 10 0 10.2 9.7 07/29/2005 17:50:00 6.7 0.8 8.4 4.6 6.3 0.8 8.4 4.6 242 6 245 305 10 0 10.2 10 07/29/2005 18:00:00 6.8 0.6 8.4 4.9 6.3 0.8 8.4 3.8 245 7 251 305 9.9 0 10.2 9.7 07/29/2005 18:10:00 6.6 0.8 8 4.6 6 0.8 7.6 4.2 241 7 242 305 10.2 0 10.2 10 07/29/2005 18:20:00 6.7 0.7 8.4 4.6 6.2 0.8 8.4 4.2 239 6 243 305 10.3 0 10.5 10.2 07/29/2005 18:30:00 6.6 0.7 8.4 4.6 6.2 0.7 7.6 4.6 238 6 240 305 10.4 0 10.5 10.2 07/29/2005 18:40:00 6.9 0.6 8.8 5.3 6.5 0.7 8.8 4.9 237 7 237 305 10.2 0 10.5 10.2 07/29/2005 18:50:00 7 0.6 8.8 4.6 6.5 0.7 8 4.6 240 6 251 305 10.4 0 10.5 10.2 07/29/2005 19:00:00 6.8 0.7 8.8 4.9 6.4 0.7 8.4 4.9 236 6 236 305 10.2 0 10.2 10 07/29/2005 19:10:00 7.2 0.7 9.1 5.3 6.7 0.7 8.8 4.9 236 6 246 305 10.2 0 10.2 10 07/29/2005 19:20:00 7.4 0.7 8.8 5.3 6.8 0.9 8.8 4.6 239 6 239 305 10.1 0 10.2 10 07/29/2005 19:30:00 6.9 0.8 8.4 4.9 6.5 0.8 8.4 4.2 235 5 231 305 10.2 0 10.2 10 07/29/2005 19:40:00 6.9 0.6 8 4.9 6.4 0.6 8 4.2 230 5 236 305 10 0 10.2 10 07/29/2005 19:50:00 6.9 0.6 8.4 4.9 6.5 0.6 8.4 4.6 228 5 227 305 10 0 10.2 9.7 07/29/2005 20:00:00 6.9 0.6 8 4.9 6.4 0.7 8 4.9 226 5 213 305 10 0 10.2 10 07/29/2005 20:10:00 7.1 0.7 8.8 4.9 6.6 0.7 8.4 4.6 228 5 227 305 9.9 0 10.2 9.7 07/29/2005 20:20:00 7.4 0.5 8.8 6.1 7 0.6 8.4 4.9 229 4 227 305 9.8 0 10 9.7 07/29/2005 20:30:00 6.9 0.6 8 5.3 6.6 0.6 8 4.6 230 4 234 305 9.8 0 10.2 9.7 07/29/2005 20:40:00 7.2 0.7 8.8 5.3 6.7 0.8 8 4.9 232 5 233 305 9.8 0 10 9.7 07/29/2005 20:50:00 7.7 0.7 8.8 5.7 7.3 0.8 8.8 4.9 230 4 230 305 9.7 0 10.2 9.5 07/29/2005 21:00:00 7.3 0.6 8.4 5.3 6.9 0.7 8.4 5.3 227 5 230 305 9.7 0 10 9.7 07/29/2005 21:10:00 7.6 0.5 8.8 5.7 7.1 0.7 8.4 5.3 227 5 234 305 9.7 0 10 9.7 07/29/2005 21:20:00 7.6 0.8 8.8 5.3 6.9 1 9.1 4.6 229 5 231 305 9.7 0 10 9.5 07/29/2005 21:30:00 8 0.6 9.1 5.7 7.4 0.7 8.8 5.3 234 3 235 305 9.5 0 9.7 9.5 07/29/2005 21:40:00 7.8 0.7 9.1 5.7 7.2 0.7 8.8 4.9 236 4 231 305 9.4 0 9.5 9.5 07/29/2005 21:50:00 7.5 0.8 9.1 5.3 7 0.8 8.8 4.9 235 5 232 305 9.3 0 9.5 9.2 07/29/2005 22:00:00 7.6 0.9 9.1 4.9 7 1 8.8 4.6 237 6 238 305 9.3 0 9.7 9.2 07/29/2005 22:10:00 8 0.6 9.5 6.5 7.4 0.8 9.1 5.7 235 8 241 305 9.2 0 9.5 9.2 07/29/2005 22:20:00 8 0.6 9.5 5.7 7.5 0.7 9.1 5.7 232 7 233 305 9.1 0 9.2 8.9 07/29/2005 22:30:00 8.4 0.7 9.9 5.7 7.9 0.8 9.5 5.7 229 5 234 305 9.1 0 9.2 8.9 07/29/2005 22:40:00 8.2 1 9.9 5.7 7.7 1 9.9 5.3 231 6 225 305 9 0.1 9.2 8.9 07/29/2005 22:50:00 8.8 0.7 9.9 6.1 8.2 0.8 9.9 6.1 228 4 224 305 8.8 0 9.2 8.9 07/29/2005 23:00:00 8.5 0.7 10.3 6.5 7.9 0.8 9.9 5.7 233 6 237 305 8.8 0.1 9.5 8.7 07/29/2005 23:10:00 8.2 0.8 10.3 5.3 7.8 1 9.9 5.3 230 5 228 305 8.8 0 9.2 8.7 07/29/2005 23:20:00 7.9 0.9 9.9 5.3 7.2 0.9 9.5 4.9 229 5 226 305 8.9 0 9.2 8.9 07/29/2005 23:30:00 7.8 1 9.9 5.3 7.2 1 9.1 5.3 238 6 231 305 8.8 0 9.2 8.9 07/29/2005 23:40:00 8.1 0.9 9.9 5.7 7.3 1 9.5 4.9 238 6 245 305 8.8 0 9.2 8.7 07/29/2005 23:50:00 7.7 0.9 9.5 5.7 7.2 0.9 8.8 4.9 232 5 238 305 8.8 0 9.2 8.7 07/30/2005 00:00:00 7.8 0.7 9.1 5.3 7.2 0.8 8.8 4.9 237 5 239 305 8.7 0 9.2 8.4 07/30/2005 00:10:00 7.9 0.7 9.1 6.1 7.3 0.7 8.8 5.3 230 7 232 305 8.5 0 8.9 8.4 07/30/2005 00:20:00 7 0.8 8.4 4.9 6.5 0.8 8 4.6 229 8 221 305 8.6 0 9.2 8.4 07/30/2005 00:30:00 6.9 0.6 8 5.7 6.5 0.7 8 4.9 226 6 231 305 8.8 0 9.2 8.7 07/30/2005 00:40:00 7.4 0.9 9.5 5.3 7 0.9 9.1 4.6 228 5 224 305 8.8 0 9.2 8.4 07/30/2005 00:50:00 6.9 0.7 8.8 4.9 6.4 0.8 8.4 4.6 229 7 241 305 8.7 0 9.2 8.4 07/30/2005 01:00:00 7.3 0.5 8.4 5.7 6.9 0.6 8 5.3 229 5 233 305 8.8 0 9.2 8.7 07/30/2005 01:10:00 7.5 0.7 8.8 5.3 7.1 0.7 8.8 4.9 229 6 223 305 8.7 0 9.2 8.4 07/30/2005 01:20:00 7.6 0.7 8.8 5.3 7.1 0.8 8.8 4.9 228 5 227 305 8.7 0 9.2 8.4 07/30/2005 01:30:00 7.2 0.7 8.8 4.9 6.4 0.7 8 4.9 233 8 218 305 8.8 0.1 9.2 8.7 07/30/2005 01:40:00 7 0.7 8.4 5.3 6.4 0.6 7.6 4.9 237 6 243 305 8.8 0 9.2 8.7 07/30/2005 01:50:00 7.6 1 9.5 4.9 7.1 0.9 9.1 4.9 236 5 237 305 8.9 0.1 9.5 8.7 07/30/2005 02:00:00 7.7 0.8 9.5 4.9 7.3 0.8 9.5 5.3 234 6 238 305 8.8 0 8.9 8.7 07/30/2005 02:10:00 7.5 0.7 9.1 5.3 6.9 0.7 8.4 5.3 236 5 239 305 8.8 0 8.9 8.7 07/30/2005 02:20:00 7.3 0.7 8.8 4.9 6.7 0.8 8.4 4.2 236 5 235 305 8.8 0 8.9 8.7 07/30/2005 02:30:00 7.1 0.6 8.8 5.7 6.7 0.6 8.4 4.9 230 6 226 305 8.8 0 9.2 8.7 07/30/2005 02:40:00 7.8 0.6 8.8 5.7 7.5 0.6 8.8 5.7 229 4 232 305 8.8 0 8.9 8.7 07/30/2005 02:50:00 7.6 0.5 8.8 5.7 7.2 0.6 8.4 5.3 230 4 231 305 8.8 0 8.9 8.7 07/30/2005 03:00:00 7.4 0.6 8.8 5.3 7 0.7 8.8 5.3 229 5 231 305 8.8 0 8.9 8.7 07/30/2005 03:10:00 7.4 0.5 8.8 5.7 7 0.7 8.4 4.6 226 5 232 305 8.7 0 9.2 8.4 07/30/2005 03:20:00 7.6 0.6 9.1 6.1 7.2 0.6 8.8 4.9 224 5 227 305 8.6 0 9.2 8.4 07/30/2005 03:30:00 7.2 0.6 8.4 5.3 6.8 0.7 8 4.6 223 4 227 305 8.7 0 9.2 8.7 07/30/2005 03:40:00 7.5 0.5 8.4 6.1 7.1 0.7 8.4 5.3 227 6 225 305 8.6 0 9.2 8.4 07/30/2005 03:50:00 7.3 0.5 8.4 6.1 6.9 0.6 8.4 4.9 217 5 218 305 8.6 0 8.7 8.4 07/30/2005 04:00:00 7.5 0.6 9.1 5.7 7.2 0.7 9.1 4.9 216 5 218 305 8.6 0 8.9 8.4 07/30/2005 04:10:00 7.1 0.5 8.4 5.7 6.8 0.6 8 4.9 219 5 227 305 8.4 0 8.9 8.4 07/30/2005 04:20:00 7.3 0.6 8.8 5.3 6.9 0.7 8.4 4.9 222 5 221 305 8.4 0.1 9.2 8.2 07/30/2005 04:30:00 7.1 0.6 8.4 4.9 6.8 0.7 8.4 4.6 224 6 223 305 8.5 0 9.2 8.2 07/30/2005 04:40:00 7.4 0.5 8.8 5.3 7.1 0.6 8.4 4.9 218 4 218 305 8.3 0.2 8.9 8.2 07/30/2005 04:50:00 7.1 0.7 8.8 4.9 6.7 0.8 8.4 4.6 220 6 230 305 8.4 0.2 8.9 8.2 07/30/2005 05:00:00 7 0.6 8.4 4.9 6.6 0.6 8 4.6 222 5 224 305 8.4 0 9.2 8.2 07/30/2005 05:10:00 6.7 0.7 8 4.6 6.4 0.8 8 4.6 217 8 218 305 8.7 0.1 9.2 8.4 07/30/2005 05:20:00 6.8 0.6 8.4 5.3 6.5 0.8 8.4 4.6 215 7 211 305 8.6 0.1 9.2 8.4 07/30/2005 05:30:00 7.2 0.5 8.4 5.3 6.8 0.6 8 4.9 220 4 218 305 8.6 0 9.2 8.4 07/30/2005 05:40:00 6.5 0.6 7.6 4.2 6.3 0.6 7.6 4.6 216 5 214 305 8.6 0.1 9.2 8.4 07/30/2005 05:50:00 6.8 0.5 8 5.7 6.6 0.6 7.6 4.6 218 4 218 305 8.4 0.1 8.9 8.2 07/30/2005 06:00:00 6.9 0.4 7.6 5.7 6.6 0.6 8 4.6 215 4 218 305 8.4 0.2 8.9 8.2 07/30/2005 06:10:00 6.8 0.5 7.6 4.9 6.5 0.6 8 4.6 217 5 212 305 8.4 0.1 8.9 8.2 07/30/2005 06:20:00 6.5 0.6 8 4.9 6.1 0.7 7.6 4.2 215 6 218 305 8.4 0 9.2 8.2 07/30/2005 06:30:00 6.9 0.5 8.4 4.6 6.5 0.7 8 4.2 215 6 215 305 8.4 0 8.7 8.2 07/30/2005 06:40:00 7.2 0.4 8.4 5.7 7 0.6 8 5.3 216 3 218 305 8.4 0 8.9 8.2 07/30/2005 06:50:00 7.3 0.5 8.4 5.7 6.9 0.7 8.4 4.9 215 4 217 305 8.4 0 8.4 8.2 07/30/2005 07:00:00 7.2 0.5 8 4.9 6.9 0.6 8.4 4.9 214 5 209 305 8.4 0 8.4 8.2 07/30/2005 07:10:00 6.7 0.6 8.4 4.9 6.4 0.7 8.4 4.9 218 5 215 305 8.4 0 8.4 8.2 07/30/2005 07:20:00 6.6 0.6 8 4.2 6.3 0.6 7.6 4.6 218 5 215 305 8.4 0 8.9 8.2 07/30/2005 07:30:00 6.9 0.7 8.4 4.6 6.6 0.8 8 4.2 219 5 221 305 8.5 0 8.7 8.4 07/30/2005 07:40:00 7 0.5 8 4.9 6.5 0.6 8 4.6 220 5 218 305 8.6 0 8.7 8.4 07/30/2005 07:50:00 7 0.5 8.4 5.3 6.6 0.6 8 4.9 222 4 230 305 8.5 0 8.7 8.4 07/30/2005 08:00:00 7.5 0.6 8.4 5.3 7 0.7 8.4 5.3 224 4 223 305 8.6 0 9.2 8.4 07/30/2005 08:10:00 7.3 0.6 8.4 5.3 6.8 0.6 8.4 4.9 227 4 224 305 8.7 0 9.2 8.7 07/30/2005 08:20:00 7 0.7 8.8 5.3 6.7 0.7 8 4.6 227 5 221 305 8.8 0 8.9 8.7 07/30/2005 08:30:00 7.3 0.6 8.8 5.3 6.9 0.7 8.8 4.9 230 5 227 305 8.8 0 8.9 8.7 07/30/2005 08:40:00 7.3 0.7 8.8 5.3 6.6 0.7 8 4.6 236 5 234 305 8.8 0 9.2 8.7 07/30/2005 08:50:00 7.3 0.7 8.4 4.9 6.6 0.8 8 4.2 235 4 234 305 8.8 0.1 9.2 8.7 07/30/2005 09:00:00 7.1 0.7 8.4 4.9 6.4 0.8 8.4 4.6 236 4 238 305 8.8 0 9.5 8.7 07/30/2005 09:10:00 7.1 0.8 8.8 4.9 6.5 0.8 8.4 4.6 234 4 233 305 8.8 0.1 9.2 8.9 07/30/2005 09:20:00 7.1 0.7 8.8 4.9 6.7 0.7 8.4 4.9 236 4 239 305 8.9 0 9.5 8.9 07/30/2005 09:30:00 6.8 0.6 8 5.3 6.3 0.7 7.6 4.6 235 5 234 305 9.1 0 9.5 8.9 07/30/2005 09:40:00 6.4 0.5 7.6 4.6 5.9 0.5 7.2 4.6 234 5 236 305 9.2 0 9.7 8.9 07/30/2005 09:50:00 7 0.4 7.6 5.3 6.6 0.5 7.6 4.9 232 4 241 305 9.3 0 9.7 9.2 07/30/2005 10:00:00 6.3 0.6 7.6 4.6 6 0.7 7.2 4.2 228 5 225 305 9.3 0.1 10 9.2 07/30/2005 10:10:00 5.8 0.5 6.8 4.2 5.4 0.6 6.8 4.2 226 5 224 305 9.4 0.1 10 9.2 07/30/2005 10:20:00 5.4 0.5 6.8 3.8 5 0.5 6.5 3.8 231 7 239 305 9.5 0 10 9.5 07/30/2005 10:30:00 6.3 0.5 7.2 4.6 5.9 0.6 7.6 3.8 239 5 236 305 9.4 0.1 10 9.2 07/30/2005 10:40:00 5.6 0.6 6.8 3.4 5.3 0.6 6.5 3.8 233 5 231 305 9.5 0 10 9.2 07/30/2005 10:50:00 5.5 0.5 6.5 4.2 5.1 0.5 6.5 3.8 238 5 241 305 9.7 0 10.2 9.5 07/30/2005 11:00:00 5.4 0.5 6.5 4.2 5.1 0.6 6.5 3.4 238 5 241 305 9.7 0 10.2 9.5 07/30/2005 11:10:00 5.1 0.5 6.5 3.4 4.7 0.5 6.1 3 241 8 217 305 9.7 0 10.2 9.7 07/30/2005 11:20:00 5 0.6 6.5 3 4.6 0.7 6.1 3 244 6 247 305 9.7 0 10 9.5 07/30/2005 11:30:00 4.8 0.6 6.1 3.4 4.7 0.6 6.1 3.4 243 6 242 305 9.7 0 10 9.7 07/30/2005 11:40:00 4.8 0.5 6.1 3.4 4.5 0.5 5.7 3.4 237 5 242 305 9.8 0 10 9.7 07/30/2005 11:50:00 4.7 0.5 6.1 3.4 4.5 0.5 6.1 3 234 5 236 305 9.8 0 10 9.7 07/30/2005 12:00:00 5.2 0.5 6.1 3.8 4.9 0.5 5.7 3.4 234 5 231 305 9.7 0 10 9.7 07/30/2005 12:10:00 4.9 0.5 6.1 3.4 4.6 0.5 6.1 3.4 235 6 244 305 9.9 0 10.2 9.7 07/30/2005 12:20:00 4.8 0.5 6.1 3.4 4.5 0.5 6.1 3 234 6 234 305 10 0 10.2 9.7 07/30/2005 12:30:00 5.2 0.6 6.5 3.8 5 0.6 6.1 3.4 231 6 232 305 9.9 0 10.2 9.7 07/30/2005 12:40:00 5.3 0.5 6.5 3.8 4.9 0.5 6.1 3.4 229 6 226 305 10 0 10.2 9.7 07/30/2005 12:50:00 5.3 0.5 6.5 3.8 5 0.5 6.1 3.4 230 7 236 305 10 0 10.2 9.7 07/30/2005 13:00:00 5.2 0.5 6.5 3.8 4.9 0.5 6.1 3.4 235 7 241 305 9.9 0 10.2 9.7 07/30/2005 13:10:00 5.2 0.6 6.5 3.8 5 0.6 6.5 3.4 234 6 238 305 10.1 0 10.2 10 07/30/2005 13:20:00 5.1 0.6 6.5 3 4.8 0.5 6.1 3.4 235 6 239 305 10 0 10.2 9.7 07/30/2005 13:30:00 5.1 0.6 6.5 3.8 4.8 0.5 6.1 3.8 236 8 218 305 10.2 0 10.2 10 07/30/2005 13:40:00 5.4 0.6 6.8 3.8 5.1 0.6 6.5 3 237 5 234 305 10.1 0 10.5 10 07/30/2005 13:50:00 5.6 0.5 6.5 4.2 5.2 0.6 6.5 3.8 235 6 237 305 10.1 0 10.2 10 07/30/2005 14:00:00 5.4 0.6 6.8 4.2 5.2 0.7 6.5 3.8 235 6 233 305 10.2 0 10.2 10 07/30/2005 14:10:00 5.6 0.6 6.8 3.4 5.3 0.6 6.5 3 235 6 233 305 10.1 0 10.2 10 07/30/2005 14:20:00 5.8 0.6 7.2 4.2 5.6 0.6 7.6 4.2 234 6 231 305 10.2 0 10.2 10 07/30/2005 14:30:00 6.1 0.6 7.6 4.2 5.8 0.6 7.6 4.2 239 6 252 305 10.2 0 10.5 10 07/30/2005 14:40:00 5.9 0.7 7.6 4.2 5.6 0.7 7.2 3.8 228 6 221 305 10.3 0 10.5 10.2 07/30/2005 14:50:00 6.2 0.5 7.6 4.6 5.9 0.6 7.6 4.6 226 7 231 305 10.2 0 10.5 10 07/30/2005 15:00:00 6.3 0.6 7.6 4.2 5.9 0.6 7.6 3.8 231 6 224 305 10.4 0 10.5 10.2 07/30/2005 15:10:00 6.4 0.5 7.6 4.9 6.1 0.5 7.6 4.6 232 5 224 305 10.4 0 10.8 10.2 07/30/2005 15:20:00 6.2 0.6 7.6 4.6 6 0.7 7.2 4.2 225 7 219 305 10.3 0 10.5 10.2 07/30/2005 15:30:00 6.3 0.6 7.6 4.6 6.1 0.6 7.2 4.2 227 7 229 305 10.2 0 10.5 10 07/30/2005 15:40:00 6.4 0.6 7.6 4.6 6.1 0.6 7.6 4.6 232 7 227 305 10.3 0.1 10.5 10 07/30/2005 15:50:00 6.6 0.7 8 4.6 6.2 0.7 7.6 4.6 232 7 229 305 10.4 0.1 10.8 10.2 07/30/2005 16:00:00 6.7 0.7 8 4.9 6.4 0.7 8 4.6 232 6 236 305 10.6 0 10.8 10.5 07/30/2005 16:10:00 7.3 0.5 8.4 5.3 6.9 0.6 8.4 5.3 230 5 221 305 10.8 0 11 10.5 07/30/2005 16:20:00 7.4 0.7 8.8 5.3 6.9 0.8 8.4 4.6 231 5 227 305 10.9 0 11.3 10.8 07/30/2005 16:30:00 7.3 0.7 8.8 5.3 6.7 0.8 8 4.9 230 5 224 305 11 0 11 10.8 07/30/2005 16:40:00 6.8 0.7 8.8 4.9 6.2 0.7 8 4.6 226 6 234 305 11 0 11.3 11 07/30/2005 16:50:00 7 0.7 8.4 5.3 6.4 0.8 8 4.2 227 6 226 305 11 0 11 10.8 07/30/2005 17:00:00 7.1 0.6 8.4 5.3 6.5 0.7 8 4.6 227 5 237 305 10.8 0 11 10.5 07/30/2005 17:10:00 7.1 0.7 8.4 5.7 6.7 0.7 8.4 4.9 228 5 230 305 10.8 0 11 10.5 07/30/2005 17:20:00 7.2 0.7 8.4 5.3 6.7 0.7 8 4.9 226 5 224 305 10.9 0 11 10.8 07/30/2005 17:30:00 6.9 0.7 8.4 4.9 6.5 0.8 8 4.6 227 6 225 305 10.8 0 11 10.8 07/30/2005 17:40:00 7.3 0.7 8.8 4.9 6.9 0.7 8.4 4.6 226 5 227 305 10.8 0 10.8 10.8 07/30/2005 17:50:00 6.9 0.7 8.8 4.9 6.5 0.8 8 4.6 228 5 237 305 10.7 0 11 10.5 07/30/2005 18:00:00 7.1 0.5 8.4 5.3 6.8 0.7 8.4 4.6 231 5 235 305 10.5 0 10.8 10.2 07/30/2005 18:10:00 6.8 0.6 8 4.9 6.5 0.6 7.6 4.6 232 5 229 305 10.4 0 10.8 10.2 07/30/2005 18:20:00 7.1 0.5 8 5.7 6.8 0.6 8 4.9 230 5 226 305 10.4 0 10.8 10.2 07/30/2005 18:30:00 6.9 0.6 8.4 4.9 6.3 0.7 8 4.6 228 5 228 305 10.6 0 10.8 10.5 07/30/2005 18:40:00 6.9 0.6 8.4 5.3 6.3 0.6 7.6 4.2 229 6 229 305 10.4 0 10.5 10.2 07/30/2005 18:50:00 6.7 0.6 8 4.9 6 0.8 7.6 3.8 229 5 231 305 10.5 0 10.8 10.2 07/30/2005 19:00:00 6.7 0.6 8 5.3 6.2 0.6 7.6 4.2 233 5 230 305 10.4 0 10.5 10.2 07/30/2005 19:10:00 6.7 0.7 8 4.6 6.1 0.8 8 4.6 235 5 239 305 10.4 0 10.5 10.2 07/30/2005 19:20:00 7 0.5 8 5.7 6.5 0.6 8 4.6 232 5 234 305 10.3 0 10.5 10.2 07/30/2005 19:30:00 6.3 0.6 8 4.6 5.8 0.6 7.2 4.2 231 5 232 305 10.2 0 10.5 10.2 07/30/2005 19:40:00 6.6 0.6 8 4.6 6 0.6 7.2 4.2 234 5 238 305 10.3 0 10.5 10.2 07/30/2005 19:50:00 6.5 0.6 7.6 4.6 5.8 0.6 6.8 4.2 233 4 225 305 10.2 0 10.5 10.2 07/30/2005 20:00:00 6.1 0.6 7.6 4.6 5.5 0.7 7.2 3.8 232 5 231 305 10.2 0 10.2 10.2 07/30/2005 20:10:00 5.7 0.6 7.2 4.2 5 0.6 6.8 3.4 236 6 239 305 10.3 0 10.5 10.2 07/30/2005 20:20:00 6.9 0.7 8.4 4.9 6.3 0.8 8 4.2 240 5 239 305 10.1 0 10.2 10 07/30/2005 20:30:00 6.7 0.7 8 4.9 6 0.7 8 3.8 245 6 246 305 10 0 10.2 10 07/30/2005 20:40:00 6.1 0.8 8 4.2 5.4 0.8 7.2 3.4 241 6 237 305 10 0 10.2 10 07/30/2005 20:50:00 6.3 0.7 7.6 4.2 5.6 0.7 7.2 3.4 240 6 246 305 10 0 10.2 10 07/30/2005 21:00:00 6.3 0.7 7.6 4.2 5.8 0.8 7.2 3.8 240 5 239 305 10 0 10.5 10 07/30/2005 21:10:00 6.2 0.6 7.6 4.6 5.6 0.7 6.8 4.2 238 5 239 305 10 0 10.5 10 07/30/2005 21:20:00 6 0.7 7.2 4.2 5.3 0.7 6.8 3.8 234 5 238 305 10 0 10.2 10 07/30/2005 21:30:00 5.8 0.5 6.8 4.2 5.5 0.5 6.5 4.2 228 6 226 305 10 0 10.2 10 07/30/2005 21:40:00 6.1 0.5 7.2 4.2 5.7 0.6 6.8 3.8 242 4 245 305 10.1 0 10.2 10 07/30/2005 21:50:00 5.9 0.8 7.2 3.8 5.5 0.8 6.8 3.4 242 5 242 305 10 0 10.2 10 07/30/2005 22:00:00 5.9 0.6 7.2 3.8 5.5 0.7 6.5 3.4 240 5 233 305 9.9 0 10 9.7 07/30/2005 22:10:00 6.2 0.5 7.2 4.6 5.8 0.6 7.2 4.2 234 5 236 305 9.8 0 10 9.7 07/30/2005 22:20:00 5.8 0.6 7.2 4.2 5.5 0.7 6.8 3 241 5 242 305 9.5 0.1 9.7 9.2 07/30/2005 22:30:00 5.5 0.6 6.8 4.2 5.1 0.7 6.1 3.4 239 6 240 305 9.2 0 9.7 9.2 07/30/2005 22:40:00 5.8 0.5 6.8 4.2 5.4 0.6 6.5 3.8 236 4 233 305 9.2 0 9.7 9.2 07/30/2005 22:50:00 5.4 0.5 6.5 3.8 5.2 0.5 6.5 3.8 230 5 226 305 9.2 0 9.7 9.2 07/30/2005 23:00:00 5.6 0.5 6.5 4.2 5.2 0.5 6.5 3.8 233 5 229 305 9.1 0 9.7 9.2 07/30/2005 23:10:00 5.6 0.5 6.5 4.2 5.3 0.6 6.8 3.8 230 5 234 305 9.2 0 9.7 9.2 07/30/2005 23:20:00 6 0.6 7.2 3.8 5.8 0.7 6.8 3.8 227 4 235 305 9.2 0 9.7 9.2 07/30/2005 23:30:00 5.8 0.6 7.2 4.2 5.6 0.6 7.2 4.2 223 5 229 305 9.3 0.1 9.7 9.2 07/30/2005 23:40:00 6 0.6 7.2 4.2 5.7 0.6 6.8 4.2 224 5 228 305 9.3 0.1 9.7 9.2 07/30/2005 23:50:00 6.5 0.5 7.6 4.6 6.2 0.6 7.6 4.6 220 5 219 305 9.4 0.1 10 9.2 07/31/2005 00:00:00 6.5 0.5 7.6 4.9 6.3 0.6 7.6 4.6 220 5 218 305 9.4 0.1 10 9.2 07/31/2005 00:10:00 6.9 0.5 8 5.3 6.6 0.6 8 4.9 219 4 218 305 9.3 0.1 9.7 9.2 07/31/2005 00:20:00 6.9 0.6 8 5.3 6.4 0.8 8 4.2 218 6 223 305 9.3 0.1 10 9.2 07/31/2005 00:30:00 6.5 0.5 7.6 4.9 6 0.6 7.2 3.8 218 5 221 305 9.4 0.1 10 9.2 07/31/2005 00:40:00 6.6 0.5 8 5.3 6.1 0.6 7.2 4.6 220 5 219 305 9.3 0.1 10 9.2 07/31/2005 00:50:00 6.4 0.5 7.6 4.9 5.8 0.6 8 4.2 223 5 224 305 9.3 0.1 10 9.2 07/31/2005 01:00:00 6.8 0.6 8.4 4.9 6.3 0.7 8.4 4.6 224 5 220 305 9.3 0 10 9.2 07/31/2005 01:10:00 7 0.6 8.4 5.3 6.4 0.7 8 4.6 228 5 229 305 9.2 0 9.7 9.2 07/31/2005 01:20:00 6.9 0.7 8.8 4.9 6.3 0.8 8.4 4.2 229 6 233 305 9.2 0 9.7 9.2 07/31/2005 01:30:00 7.1 0.6 8.4 4.9 6.4 0.7 8.4 4.6 233 5 231 305 9.3 0 9.7 9.2 07/31/2005 01:40:00 7 0.8 9.1 4.9 6.3 0.9 8.4 4.6 236 6 238 305 9.3 0.1 9.7 9.2 07/31/2005 01:50:00 7.5 0.8 9.5 5.7 6.8 0.9 9.1 4.6 234 6 235 305 9.2 0 9.7 9.2 07/31/2005 02:00:00 6.7 0.6 8.4 4.6 6.1 0.7 7.6 4.2 234 6 238 305 9.3 0.1 9.7 9.2 07/31/2005 02:10:00 6.7 0.7 8 4.6 6.2 0.7 7.6 4.2 232 5 238 305 9.5 0 10 9.5 07/31/2005 02:20:00 6.9 0.5 8 4.9 6.4 0.7 7.6 4.2 230 5 225 305 9.5 0 10 9.5 07/31/2005 02:30:00 7.1 0.6 8.4 4.9 6.4 0.7 8 4.6 235 5 238 305 9.5 0 10.2 9.5 07/31/2005 02:40:00 6.9 0.6 8.4 4.9 6.3 0.7 8 3.8 237 6 243 305 9.6 0 10.2 9.5 07/31/2005 02:50:00 6.6 0.6 8 4.9 5.8 0.7 7.2 3.8 237 5 238 305 9.6 0 10.2 9.5 07/31/2005 03:00:00 7 0.9 9.1 4.6 6.2 1 8.4 3.8 245 7 251 305 9.6 0.1 10.2 9.5 07/31/2005 03:10:00 7.4 0.8 9.1 4.9 6.7 0.9 8.8 4.2 244 5 245 305 9.5 0.1 10 9.5 07/31/2005 03:20:00 7.3 0.6 8.4 5.7 6.5 0.8 8 4.2 245 5 238 305 9.5 0 10 9.5 07/31/2005 03:30:00 6.6 0.9 8.8 4.6 5.8 1 8 3.4 243 7 247 305 9.5 0 10.2 9.5 07/31/2005 03:40:00 6.6 0.7 8.4 4.9 5.8 0.8 7.6 3.4 241 6 236 305 9.5 0.1 10.2 9.5 07/31/2005 03:50:00 7.1 0.6 8.8 4.9 6.3 0.7 8 4.6 240 5 240 305 9.6 0 10.2 9.5 07/31/2005 04:00:00 7 0.6 8.4 5.3 6.3 0.8 8 4.2 240 5 240 305 9.6 0 10.2 9.5 07/31/2005 04:10:00 7 0.6 8 4.9 6.4 0.7 7.6 4.2 243 4 250 305 9.7 0 10.2 9.5 07/31/2005 04:20:00 6.3 0.9 8.4 3.4 5.3 1.1 8 2.3 254 8 251 305 9.8 0 10.2 9.7 07/31/2005 04:30:00 6.7 0.7 8.8 4.9 5.4 0.8 7.6 3.4 258 6 251 305 9.7 0 10.2 9.7 07/31/2005 04:40:00 6.6 0.7 8 4.6 5.6 0.9 7.6 3.4 255 6 256 305 9.7 0 10.2 9.7 07/31/2005 04:50:00 6.5 1 8.8 3.8 4.9 1 8 2.3 265 7 268 305 9.6 0.1 10.2 9.5 07/31/2005 05:00:00 6.3 0.9 8.4 4.2 4.9 0.8 6.8 2.6 266 7 269 305 9.5 0.1 10 9.5 07/31/2005 05:10:00 6.5 0.6 8 4.6 5.2 0.8 6.8 2.6 261 7 251 305 9.4 0.1 10 9.2 07/31/2005 05:20:00 6.3 0.7 7.6 4.2 5 0.9 7.6 2.6 257 8 251 305 9.4 0 10 9.2 07/31/2005 05:30:00 6.3 0.9 8.4 3 5.1 1 7.2 2.3 262 9 249 305 9.3 0.1 10 9.2 07/31/2005 05:40:00 6.3 0.8 8 4.2 4.9 0.9 6.8 2.3 259 7 263 305 9.3 0.1 10 9.2 07/31/2005 05:50:00 6.2 0.7 8 4.6 5.3 0.9 7.6 3 251 6 254 305 9.3 0.1 10 9.2 07/31/2005 06:00:00 6.3 0.8 8 4.6 5.4 1 7.6 3 251 6 250 305 9.4 0.1 10 9.5 07/31/2005 06:10:00 6.2 0.8 7.6 3.4 5.4 1 7.6 3 251 6 252 305 9.5 0 10 9.2 07/31/2005 06:20:00 6 0.6 7.6 4.2 5.2 0.9 7.2 3 253 6 256 305 9.5 0 10 9.5 07/31/2005 06:30:00 5.8 0.7 7.6 3.4 4.8 0.9 6.8 2.6 253 7 257 305 9.5 0 10 9.5 07/31/2005 06:40:00 5.5 0.6 7.2 3.8 4.4 0.6 6.5 2.6 255 8 258 305 9.5 0 10 9.5 07/31/2005 06:50:00 5.5 0.9 7.6 3 4.6 0.8 7.2 2.6 260 8 258 305 9.7 0 10.2 9.5 07/31/2005 07:00:00 5.5 0.7 7.2 3.4 4.8 0.7 6.5 3 256 8 268 305 9.7 0 9.7 9.5 07/31/2005 07:10:00 5.9 0.9 8 3.8 4.7 0.7 6.5 3 261 6 266 305 9.7 0 10 9.5 07/31/2005 07:20:00 5.2 0.7 6.8 3.4 4.3 0.6 6.1 2.6 261 9 268 305 9.7 0 10 9.7 07/31/2005 07:30:00 5.7 1 7.2 3 4.5 0.9 7.2 2.3 258 7 261 305 9.8 0 10.2 9.7 07/31/2005 07:40:00 6.1 0.6 7.6 4.2 4.8 0.8 6.8 3 259 5 258 305 9.8 0 10.2 9.7 07/31/2005 07:50:00 5 1 7.6 2.6 4 0.8 6.1 1.9 262 8 265 305 9.9 0.1 10.2 9.7 07/31/2005 08:00:00 5.3 1.1 7.2 2.6 4 0.8 6.1 2.3 266 7 263 305 9.9 0 10.2 10 07/31/2005 08:10:00 5.3 1 7.6 3 4 0.9 6.5 1.9 266 7 261 305 9.9 0 10.5 10 07/31/2005 08:20:00 4.6 0.9 6.5 2.6 3.7 0.9 5.7 1.5 272 9 285 305 10 0 10.5 10 07/31/2005 08:30:00 5 0.9 6.8 2.6 4.1 0.9 6.1 1.9 271 9 267 305 10.1 0 10.5 10 07/31/2005 08:40:00 5.4 0.9 7.2 3 4.4 0.8 6.5 2.6 277 8 275 305 10.1 0 10.5 10 07/31/2005 08:50:00 5.5 0.6 6.8 3.8 4 0.6 5.7 2.6 268 6 269 305 10.2 0 10.5 10 07/31/2005 09:00:00 4.6 0.8 7.2 2.6 3.7 0.7 5.3 2.3 270 10 263 305 10.2 0 10.5 10.2 07/31/2005 09:10:00 4.2 0.7 6.1 2.6 3.5 0.8 6.1 1.9 277 9 290 305 10.3 0 10.5 10.2 07/31/2005 09:20:00 5.5 1 7.6 3 4.3 1 6.5 2.3 273 8 281 305 10.2 0 10.8 10.2 07/31/2005 09:30:00 5.5 0.7 7.2 3.8 4.2 0.7 6.1 2.3 270 7 275 305 10.2 0 10.8 10.2 07/31/2005 09:40:00 4.9 0.7 6.5 2.3 3.8 0.7 6.1 1.9 266 8 264 305 10.2 0 10.5 10.2 07/31/2005 09:50:00 4.9 0.8 7.2 3 4 0.7 6.1 2.3 263 8 262 305 10.3 0 10.2 10.2 07/31/2005 10:00:00 5.4 0.6 6.8 3.4 4.2 0.7 5.7 2.3 269 9 255 305 10.3 0 10.8 10.2 07/31/2005 10:10:00 5.2 0.9 6.8 2.6 4.4 0.8 6.1 2.6 276 9 270 305 10.3 0 10.8 10.2 07/31/2005 10:20:00 5.5 0.8 7.2 3.4 4.4 0.7 6.1 2.6 271 8 268 305 10.3 0 10.8 10.2 07/31/2005 10:30:00 4 0.7 6.1 2.3 3.4 0.7 5.3 1.9 274 10 281 305 10.3 0 10.8 10.2 07/31/2005 10:40:00 4.9 1 6.8 2.6 3.8 0.8 6.1 2.3 266 9 275 305 10.3 0 10.5 10.2 07/31/2005 10:50:00 4.7 0.8 6.5 2.3 3.8 0.7 5.3 1.9 266 8 269 305 10.3 0 10.8 10.2 07/31/2005 11:00:00 5 0.8 6.8 3 3.9 0.6 5.7 2.3 269 8 270 305 10.3 0 10.5 10.2 07/31/2005 11:10:00 5.2 0.7 6.8 3.4 4.1 0.7 6.1 2.3 270 8 265 305 10.4 0 10.5 10.2 07/31/2005 11:20:00 4.6 0.6 6.5 3 3.8 0.7 6.1 2.3 273 10 286 305 10.5 0 10.5 10.5 07/31/2005 11:30:00 5 1 7.2 3 4.4 1 6.8 2.3 281 8 275 305 10.4 0 10.5 10.2 07/31/2005 11:40:00 5.2 0.7 6.8 2.6 4.3 0.7 6.1 2.3 272 9 279 305 10.4 0 10.5 10.2 07/31/2005 11:50:00 4.7 0.6 6.1 3 3.9 0.6 6.1 2.6 270 12 259 305 10.4 0 10.5 10.2 07/31/2005 12:00:00 5.3 0.8 6.8 3 4.4 0.8 6.1 2.3 272 8 275 305 10.4 0 10.5 10.2 07/31/2005 12:10:00 4.6 0.7 6.5 2.3 3.8 0.6 5.3 1.9 266 10 265 305 10.4 0 10.5 10.2 07/31/2005 12:20:00 4 0.8 6.5 2.3 3.3 0.7 5.7 1.5 266 11 273 305 10.4 0 10.5 10.2 07/31/2005 12:30:00 5.1 0.7 6.8 3 4.4 0.8 6.5 2.3 274 8 275 305 10.4 0 10.5 10.2 07/31/2005 12:40:00 4.9 1 7.2 2.6 3.8 0.8 6.1 1.9 269 8 268 305 10.3 0 10.5 10.2 07/31/2005 12:50:00 4 0.8 6.1 2.3 3.3 0.7 5.3 1.5 271 9 273 305 10.4 0 10.5 10.2 07/31/2005 13:00:00 4.5 0.6 6.1 3 3.7 0.6 5.7 2.3 269 9 281 305 10.4 0 10.5 10.2 07/31/2005 13:10:00 4.9 0.6 6.5 3.4 4 0.6 5.7 2.6 267 9 266 305 10.4 0.1 10.8 10.2 07/31/2005 13:20:00 4.6 0.7 6.1 2.3 3.8 0.7 5.3 2.3 259 9 259 305 10.4 0 10.5 10.2 07/31/2005 13:30:00 4.4 0.8 6.5 2.3 3.6 0.7 4.9 1.5 263 9 270 305 10.4 0 10.8 10.2 07/31/2005 13:40:00 4.6 0.6 6.1 3 4 0.6 5.3 2.3 259 13 273 305 10.6 0 10.8 10.2 07/31/2005 13:50:00 4.3 0.9 6.1 1.9 3.8 1 6.5 1.5 260 9 254 305 10.6 0 10.8 10.2 07/31/2005 14:00:00 5 0.6 6.5 3.4 4.1 0.6 6.1 2.6 260 8 254 305 10.5 0 10.8 10.2 07/31/2005 14:10:00 4.5 0.7 6.5 3 4.3 0.7 6.1 2.6 249 8 250 305 10.5 0.1 10.8 10.2 07/31/2005 14:20:00 5.1 0.8 6.8 3 4.5 0.7 6.8 3 256 10 261 305 10.5 0 10.8 10.2 07/31/2005 14:30:00 4.8 0.6 6.5 3 4.6 0.6 6.1 2.6 251 8 276 305 10.4 0 10.5 10.2 07/31/2005 14:40:00 4.4 0.8 6.5 2.6 4 0.7 5.7 2.6 254 9 255 305 10.5 0 10.8 10.2 07/31/2005 14:50:00 5 0.6 6.5 3.4 4.7 0.7 6.5 2.3 253 7 256 305 10.5 0 10.5 10.5 07/31/2005 15:00:00 4.5 0.6 6.1 2.6 3.9 0.6 5.3 2.3 257 9 251 305 10.4 0 10.5 10.2 07/31/2005 15:10:00 4.5 0.5 5.7 3 3.8 0.6 5.3 2.3 258 8 264 305 10.6 0 10.8 10.5 07/31/2005 15:20:00 5.1 0.7 6.8 3.4 4.5 0.7 6.5 2.6 256 8 258 305 10.6 0 10.8 10.5 07/31/2005 15:30:00 5.2 0.8 6.8 2.3 4.6 0.8 6.8 3 253 9 259 305 10.6 0 10.8 10.5 07/31/2005 15:40:00 5.2 0.6 6.5 3.8 4.9 0.8 6.5 2.6 253 6 251 305 10.4 0 10.8 10.2 07/31/2005 15:50:00 4.8 0.7 6.1 3 4.5 0.8 6.1 2.6 247 9 258 305 10.5 0 10.8 10.2 07/31/2005 16:00:00 4.6 0.6 6.1 3 4.4 0.5 5.7 3 248 8 259 305 10.6 0 10.8 10.5 07/31/2005 16:10:00 4.6 0.6 6.1 3.4 4.4 0.6 5.7 2.6 250 9 256 305 10.6 0 10.8 10.5 07/31/2005 16:20:00 4.5 0.7 6.5 3 4.2 0.7 6.5 2.6 250 9 257 305 10.6 0 10.8 10.5 07/31/2005 16:30:00 4.6 1.1 6.5 2.6 3.8 0.9 5.7 1.9 257 9 263 305 10.6 0 10.8 10.5 07/31/2005 16:40:00 4.4 0.5 5.7 3 4.2 0.6 6.1 2.6 247 8 252 305 10.6 0 10.8 10.5 07/31/2005 16:50:00 4.5 0.6 6.1 3 4.2 0.5 5.3 2.6 252 10 266 305 10.7 0 10.8 10.5 07/31/2005 17:00:00 4.9 0.7 6.8 3 4.4 0.7 6.1 2.6 253 8 261 305 10.6 0 10.8 10.5 07/31/2005 17:10:00 4.8 0.7 6.8 3 4.4 0.8 6.5 2.6 253 8 264 305 10.3 0 10.8 10.2 07/31/2005 17:20:00 4.4 0.6 5.7 2.3 4.1 0.7 5.7 2.6 251 8 254 305 10.3 0 10.5 10.2 07/31/2005 17:30:00 4.8 0.6 6.1 3 4.5 0.6 6.1 2.6 249 6 251 305 10.4 0 10.5 10.2 07/31/2005 17:40:00 5.3 0.8 7.2 3.4 4.8 0.7 6.5 3 251 7 251 305 10.4 0 10.8 10.2 07/31/2005 17:50:00 4.3 0.5 6.1 3 4.1 0.6 5.7 2.6 247 8 251 305 10.4 0 10.5 10.2 07/31/2005 18:00:00 4.8 0.6 6.5 2.6 4.3 0.7 6.5 2.3 248 9 261 305 10.4 0 10.5 10.2 07/31/2005 18:10:00 5 0.7 6.5 3 4.2 0.7 6.1 2.6 253 10 251 305 10.6 0 10.8 10.5 07/31/2005 18:20:00 4.9 0.7 6.5 2.6 4.6 0.8 6.8 2.6 254 7 264 305 10.4 0 10.5 10.2 07/31/2005 18:30:00 4.9 0.7 6.8 2.6 4.4 0.7 6.1 3 253 8 261 305 10.3 0 10.5 10.2 07/31/2005 18:40:00 4.8 0.7 6.5 3 4.3 0.7 5.7 2.6 251 8 254 305 10.3 0 10.5 10.2 07/31/2005 18:50:00 4.6 0.6 6.5 2.6 4.1 0.7 6.1 2.3 253 9 247 305 10.3 0 10.5 10.2 07/31/2005 19:00:00 4.4 0.5 5.3 3 4.1 0.7 6.1 2.3 252 9 239 305 10.2 0 10.5 10.2 07/31/2005 19:10:00 4.3 0.6 6.1 2.6 3.7 0.7 5.7 2.3 256 8 255 305 10.3 0 10.5 10.2 07/31/2005 19:20:00 4.3 0.6 6.1 2.6 3.8 0.6 4.9 2.3 255 8 253 305 10.3 0 10.5 10.2 07/31/2005 19:30:00 4.1 0.6 5.7 2.6 3.7 0.6 5.3 2.3 253 10 264 305 10.4 0 10.5 10.2 07/31/2005 19:40:00 4.4 0.6 6.1 3 4 0.6 5.3 2.6 250 8 255 305 10.4 0 10.5 10.2 07/31/2005 19:50:00 4.1 0.6 5.3 2.6 3.6 0.6 5.3 1.9 254 11 268 305 10.4 0 10.5 10.2 07/31/2005 20:00:00 4.1 0.5 5.3 2.6 3.7 0.6 4.9 1.9 247 10 266 305 10.4 0 10.5 10.2 07/31/2005 20:10:00 4.6 0.6 6.1 2.6 4.1 0.7 5.7 1.9 252 9 258 305 10.3 0 10.5 10.2 07/31/2005 20:20:00 4.5 0.6 6.1 3 4.2 0.6 6.1 2.6 245 11 242 305 10.3 0 10.2 10.2 07/31/2005 20:30:00 4.4 0.9 6.5 2.6 4.1 0.9 6.5 2.3 254 9 254 305 10.2 0 10.2 10 07/31/2005 20:40:00 4.4 1 6.5 2.3 4.2 0.8 6.5 2.3 247 6 238 305 10.1 0 10.2 10 07/31/2005 20:50:00 5 0.6 6.8 3.4 4.5 0.6 6.1 3 247 7 251 305 10.1 0 10.5 10 07/31/2005 21:00:00 4.6 0.6 6.1 3 4.2 0.6 5.7 2.6 245 7 249 305 10.1 0 10.2 10 07/31/2005 21:10:00 4.6 0.7 7.2 3 4.2 0.7 6.8 2.6 248 10 256 305 10.1 0 10.5 10 07/31/2005 21:20:00 5 0.5 6.5 3.4 4.5 0.6 6.1 2.6 252 8 258 305 10 0 10.5 10 07/31/2005 21:30:00 4.9 0.6 6.1 3 4.1 0.6 6.1 2.6 248 9 256 305 10.1 0 10.5 10 07/31/2005 21:40:00 4.5 0.5 5.7 3 4.1 0.5 5.3 3 248 8 261 305 10.1 0 10.5 10 07/31/2005 21:50:00 4.7 0.5 6.5 3 4.3 0.6 5.7 2.6 250 8 251 305 10 0 10.5 10 07/31/2005 22:00:00 4.4 0.6 5.7 2.6 4.1 0.6 5.3 2.6 250 6 246 305 10 0 10.5 10 07/31/2005 22:10:00 4.2 0.7 6.1 2.6 3.8 0.6 6.1 2.3 248 8 256 305 10 0 10.5 10 07/31/2005 22:20:00 4.3 0.6 5.7 2.3 4.1 0.5 5.7 2.6 247 6 243 305 10 0 10.5 10 07/31/2005 22:30:00 5.1 0.6 6.5 3.4 4.7 0.7 6.5 2.6 250 7 247 305 10 0 10.5 10 07/31/2005 22:40:00 4.1 0.7 5.7 1.9 3.8 0.6 5.3 2.3 244 11 251 305 10 0 10.2 10 07/31/2005 22:50:00 3.9 0.6 5.3 2.6 3.7 0.5 5.3 2.6 235 8 232 305 10.2 0 10.8 10.2 07/31/2005 23:00:00 4.1 0.5 5.3 3 3.8 0.5 4.9 2.6 241 7 234 305 10.3 0 10.5 10.2 07/31/2005 23:10:00 5.1 0.5 6.5 3.8 4.5 0.6 6.1 3 248 8 254 305 10.3 0 10.5 10.2 07/31/2005 23:20:00 5.2 0.5 6.5 3.8 4.8 0.6 6.8 3.4 246 6 250 305 10.3 0 10.5 10.2 07/31/2005 23:30:00 4.8 0.5 6.1 3.4 4.4 0.5 5.7 3 244 7 261 305 10.3 0 10.5 10.2 07/31/2005 23:40:00 4.8 0.6 6.8 3.8 4.5 0.6 6.5 3 243 7 241 305 10.3 0 10.5 10.2 07/31/2005 23:50:00 4.8 0.7 6.5 3 4.4 0.7 6.1 2.6 244 7 251 305 10.3 0 10.5 10.2 08/01/2005 00:00:00 4.8 0.5 6.5 3.4 4.3 0.5 5.7 3.4 245 8 256 305 10.4 0 10.8 10 08/01/2005 00:10:00 4.6 0.5 5.7 3.4 4.2 0.5 5.3 3.4 240 7 242 305 10.4 0 10.8 10.2 08/01/2005 00:20:00 4.9 0.5 6.5 3.8 4.5 0.5 5.7 3 243 6 246 305 10.4 0 10.8 10.2 08/01/2005 00:30:00 4.8 0.6 6.1 2.6 4.5 0.6 5.7 2.6 246 6 252 305 10.4 0 10.8 10.2 08/01/2005 00:40:00 4.7 0.5 6.5 3 4.2 0.5 5.3 3 245 6 258 305 10.4 0 10.8 10.2 08/01/2005 00:50:00 4.5 0.5 5.7 3 4.2 0.5 5.3 3 240 8 240 305 10.4 0 10.8 10.2 08/01/2005 01:00:00 4.9 0.5 6.1 3.4 4.6 0.5 6.1 3 239 6 242 305 10.4 0 10.8 10.2 08/01/2005 01:10:00 5.3 0.5 6.5 3.4 4.9 0.6 6.1 3.4 242 6 241 305 10.3 0 10.8 10.2 08/01/2005 01:20:00 5.2 0.6 6.5 3.4 4.8 0.6 6.1 3.4 244 5 251 305 10.3 0 10.5 10.2 08/01/2005 01:30:00 5.2 0.6 6.8 3.8 4.8 0.7 6.5 2.6 245 7 241 305 10.3 0 10.5 10.2 08/01/2005 01:40:00 5.1 0.5 6.1 3.4 4.7 0.6 6.1 3.4 245 6 256 305 10.2 0 10.5 10.2 08/01/2005 01:50:00 5.2 0.5 6.1 3.8 4.9 0.6 6.1 3.4 242 6 238 305 10.3 0 10.8 10.2 08/01/2005 02:00:00 5.1 0.7 6.8 3.8 4.7 0.7 6.5 3 245 6 246 305 10.2 0 10.8 10.2 08/01/2005 02:10:00 5.4 0.5 6.8 4.2 5 0.6 6.1 3.4 245 5 245 305 10.2 0 10.5 10 08/01/2005 02:20:00 4.9 0.6 6.5 3.4 4.6 0.6 6.5 3 242 6 246 305 10.2 0 10.5 10 08/01/2005 02:30:00 4.5 0.5 5.7 3 4.2 0.5 5.3 2.6 233 7 241 305 10.2 0 10.5 10.2 08/01/2005 02:40:00 4.7 0.4 5.7 3.4 4.4 0.5 5.7 3 228 6 232 305 10.2 0 10.5 10.2 08/01/2005 02:50:00 4.6 0.4 5.7 3.4 4.3 0.4 5.7 3.4 226 6 221 305 10.2 0 10.5 10 08/01/2005 03:00:00 4.9 0.4 6.1 3.8 4.7 0.4 5.7 3.4 221 6 216 305 10.2 0 10.5 10.2 08/01/2005 03:10:00 4.7 0.5 6.1 3.4 4.5 0.5 6.1 3.4 224 6 223 305 10.2 0 10.5 10.2 08/01/2005 03:20:00 4.4 0.4 5.7 3 4.2 0.5 5.3 3 223 6 227 305 10.2 0 10.5 10.2 08/01/2005 03:30:00 4.3 0.4 5.3 3.4 4.1 0.4 5.3 3 222 6 217 305 10.3 0 10.5 10.2 08/01/2005 03:40:00 4.6 0.6 6.1 3 4.3 0.5 5.7 2.3 230 9 235 305 10.3 0 10.8 10.2 08/01/2005 03:50:00 4.8 0.5 6.1 3.8 4.4 0.5 5.7 3 235 6 239 305 10.3 0 10.8 10.2 08/01/2005 04:00:00 4.8 0.4 5.7 3.8 4.5 0.5 5.7 3.4 236 6 237 305 10.3 0 10.5 10.2 08/01/2005 04:10:00 5 0.4 6.1 3.8 4.7 0.5 5.7 3.4 232 6 244 305 10.3 0 10.2 10.2 08/01/2005 04:20:00 4.9 0.5 6.1 3.4 4.5 0.5 5.7 3 229 6 228 305 10.3 0 10.5 10.2 08/01/2005 04:30:00 4.8 0.5 6.1 3.4 4.5 0.5 5.7 3.4 227 6 239 305 10.3 0 10.2 10.2 08/01/2005 04:40:00 4.6 0.5 5.7 3 4.3 0.5 5.3 2.6 224 7 231 305 10.2 0 10.2 10.2 08/01/2005 04:50:00 4.7 0.5 6.5 3.8 4.5 0.4 6.1 3.4 220 6 225 305 10.2 0 10.2 10.2 08/01/2005 05:00:00 5 0.4 5.7 4.2 4.9 0.4 5.7 4.2 219 5 227 305 10.2 0 10.2 10 08/01/2005 05:10:00 5 0.4 6.1 4.2 4.7 0.4 5.7 3.4 219 6 221 305 10.2 0 10.2 10.2 08/01/2005 05:20:00 5 0.5 6.1 3.8 4.7 0.5 6.1 3.4 223 5 230 305 10.2 0 10.2 10.2 08/01/2005 05:30:00 5.2 0.4 6.5 4.2 5 0.4 6.1 3.8 220 5 218 305 10.1 0 10.2 10 08/01/2005 05:40:00 5.5 0.5 6.5 4.2 5.1 0.5 6.5 3.8 225 5 228 305 10.1 0 10.2 10 08/01/2005 05:50:00 5.5 0.5 6.8 4.2 5.1 0.5 6.5 3.4 228 5 224 305 10.1 0 10.5 10 08/01/2005 06:00:00 5.4 0.4 6.5 3.8 4.9 0.5 6.1 3 228 5 221 305 10.1 0 10.2 10 08/01/2005 06:10:00 5.1 0.5 6.1 3.8 4.8 0.5 6.1 3.4 231 6 234 305 10.1 0 10.2 10 08/01/2005 06:20:00 5.2 0.4 6.5 4.2 4.9 0.4 6.1 3.8 234 5 231 305 10.2 0 10.5 10 08/01/2005 06:30:00 5.2 0.6 6.5 3.8 4.8 0.6 6.1 3 240 7 252 305 10.2 0 10.5 10 08/01/2005 06:40:00 5.3 0.6 6.8 3.8 4.9 0.6 6.1 3.4 238 6 238 305 10.2 0 10.5 10 08/01/2005 06:50:00 5.6 0.7 7.2 3.8 5.2 0.7 6.8 3.8 235 6 237 305 10.2 0 10.5 10 08/01/2005 07:00:00 6 0.5 7.2 4.6 5.6 0.7 7.2 4.2 235 6 236 305 10.2 0 10.5 10 08/01/2005 07:10:00 6.1 0.6 7.6 4.2 5.6 0.6 6.8 4.2 238 6 242 305 10.1 0 10.5 10 08/01/2005 07:20:00 6.2 0.7 7.2 3.8 5.8 0.7 6.8 3.8 242 7 245 305 10 0.1 10.5 10 08/01/2005 07:30:00 6.4 0.7 8 4.2 5.9 0.8 7.6 3.4 241 5 241 305 9.9 0.1 10.2 10 08/01/2005 07:40:00 6.3 0.7 8 4.6 5.9 0.7 7.6 4.2 241 5 240 305 9.9 0 10.2 9.7 08/01/2005 07:50:00 6.5 0.6 8 4.6 6 0.6 7.6 4.2 239 5 232 305 9.9 0.1 10.2 9.7 08/01/2005 08:00:00 6.4 0.7 7.6 4.6 5.8 0.7 7.2 3.8 243 6 243 305 9.9 0.1 10.2 9.7 08/01/2005 08:10:00 6.3 0.7 8 4.2 5.5 0.8 7.6 3 249 6 247 305 10 0 10.2 10 08/01/2005 08:20:00 6.1 0.6 7.2 4.2 5.4 0.7 7.2 3 246 7 255 305 10 0 10.5 10 08/01/2005 08:30:00 5.1 0.6 6.8 3.8 4.7 0.6 6.1 3 246 8 242 305 10.1 0 10.5 10 08/01/2005 08:40:00 5.4 0.8 6.8 3 5.1 0.9 6.8 2.6 242 7 239 305 10 0 10.2 10 08/01/2005 08:50:00 6.1 0.6 7.2 4.6 5.6 0.6 7.2 4.2 240 5 242 305 10 0 10.2 10 08/01/2005 09:00:00 5.8 0.7 7.2 3.8 5.2 0.7 6.8 3.4 238 6 238 305 10 0 10.2 9.7 08/01/2005 09:10:00 6.2 0.6 7.2 4.2 5.5 0.7 7.2 3.4 237 5 238 305 9.9 0 10.2 10 08/01/2005 09:20:00 5.9 0.6 7.2 3.8 5.2 0.7 6.5 3.4 248 6 242 305 9.9 0 10 9.7 08/01/2005 09:30:00 5.5 0.8 6.8 3.4 4.9 1 6.8 3 244 8 243 305 10 0 10.2 9.7 08/01/2005 09:40:00 5.9 0.5 7.2 4.6 5.5 0.6 6.8 4.2 239 6 244 305 9.9 0 10 9.7 08/01/2005 09:50:00 5.9 0.6 7.2 4.2 5.6 0.6 6.8 4.2 235 5 231 305 9.7 0 10 9.7 08/01/2005 10:00:00 6 0.6 7.2 4.6 5.8 0.6 7.2 4.2 235 5 232 305 9.8 0 10 9.7 08/01/2005 10:10:00 5.8 0.6 7.2 4.2 5.4 0.6 6.8 3.8 237 5 239 305 9.9 0 10 9.7 08/01/2005 10:20:00 5.6 0.7 7.2 3.8 5.2 0.7 6.8 3.4 238 6 239 305 10 0 10.2 10 08/01/2005 10:30:00 5.8 0.7 7.2 3.8 5.5 0.7 6.8 3 244 7 240 305 9.9 0 10.2 10 08/01/2005 10:40:00 6.1 0.5 7.2 4.9 5.6 0.5 6.5 4.2 239 5 239 305 10 0 10.2 10 08/01/2005 10:50:00 5.7 0.5 6.8 4.6 5.3 0.5 6.5 4.2 238 5 238 305 10 0 10.2 10 08/01/2005 11:00:00 5.5 0.5 6.8 3.8 5.2 0.6 6.5 3.8 241 6 251 305 10.1 0 10.5 9.7 08/01/2005 11:10:00 5.8 0.6 7.2 3.8 5.5 0.7 6.8 3.8 243 6 232 305 10.2 0 10.5 10 08/01/2005 11:20:00 6 0.5 7.2 4.2 5.7 0.6 6.8 3.8 241 6 246 305 10.2 0 10.5 10 08/01/2005 11:30:00 5.9 0.6 7.2 4.2 5.4 0.7 7.2 3.8 241 6 248 305 10.2 0 10.5 10 08/01/2005 11:40:00 5.6 0.6 6.8 3.8 5.1 0.6 6.5 3.4 237 6 237 305 10.4 0 10.5 10.2 08/01/2005 11:50:00 5.6 0.6 7.2 4.2 4.9 0.7 6.5 3 240 6 250 305 10.4 0 10.5 10.2 08/01/2005 12:00:00 5.5 0.5 6.5 3.8 5 0.5 6.1 3.4 241 5 245 305 10.2 0 10.2 10.2 08/01/2005 12:10:00 5.3 0.6 6.5 3.8 4.7 0.7 6.1 3.4 244 8 248 305 10.2 0 10.2 10.2 08/01/2005 12:20:00 5.4 0.5 6.5 4.2 4.8 0.5 6.1 3.4 232 6 240 305 10.3 0 10.5 10.2 08/01/2005 12:30:00 5.2 0.6 6.5 3.4 4.6 0.6 6.1 2.6 241 8 240 305 10.4 0 10.8 10.2 08/01/2005 12:40:00 5.2 0.7 6.8 3.8 5 0.7 6.5 3.4 237 7 235 305 10.4 0 10.8 10.2 08/01/2005 12:50:00 5.8 0.5 7.2 4.2 5.4 0.6 6.5 3.8 241 6 246 305 10.3 0 10.5 10.2 08/01/2005 13:00:00 5.1 0.5 6.5 3.8 4.8 0.5 6.5 3.4 234 8 242 305 10.4 0 10.5 10.2 08/01/2005 13:10:00 5.6 0.6 6.8 4.2 5.3 0.6 6.8 3.8 237 5 238 305 10.5 0 10.8 10.2 08/01/2005 13:20:00 5.6 0.6 6.8 4.2 5.3 0.6 6.5 3.8 233 6 249 305 10.5 0 10.8 10.2 08/01/2005 13:30:00 5.6 0.5 6.5 4.2 5.3 0.5 6.5 4.2 232 6 231 305 10.5 0 10.8 10.2 08/01/2005 13:40:00 5.6 0.5 6.8 4.2 5.2 0.6 6.8 3.8 233 5 234 305 10.6 0 10.8 10.5 08/01/2005 13:50:00 5.3 0.5 6.5 3.8 5.1 0.5 6.1 3.4 232 9 243 305 10.6 0 10.8 10.5 08/01/2005 14:00:00 5.6 0.5 6.8 4.2 5.3 0.5 6.5 3.4 227 5 219 305 10.4 0 10.5 10.2 08/01/2005 14:10:00 5.4 0.6 6.5 3.8 5.1 0.5 6.5 3.8 228 6 224 305 10.4 0 10.8 10.2 08/01/2005 14:20:00 5.4 0.5 6.5 3.8 5.1 0.6 6.1 3.4 229 5 232 305 10.3 0 10.5 10.2 08/01/2005 14:30:00 5.5 0.4 6.5 3.8 5.2 0.5 6.1 4.2 231 5 231 305 10.4 0 10.5 10.2 08/01/2005 14:40:00 4.9 0.5 6.5 3.4 4.6 0.5 6.1 3 233 7 230 305 10.5 0 10.8 10.2 08/01/2005 14:50:00 5.2 0.5 6.5 3.8 4.9 0.5 6.1 3.4 234 5 234 305 10.6 0 10.8 10.5 08/01/2005 15:00:00 5.3 0.5 6.1 3.8 5.1 0.5 6.1 3.8 228 6 235 305 10.5 0 10.8 10.2 08/01/2005 15:10:00 5 0.6 6.1 3.4 4.7 0.6 6.1 3.4 228 7 234 305 10.7 0 11 10.5 08/01/2005 15:20:00 5 0.6 6.1 3.4 4.8 0.6 5.7 3 239 6 238 305 10.8 0 11 10.5 08/01/2005 15:30:00 5.5 0.6 6.8 3.8 5.2 0.7 6.5 3.4 233 7 223 305 10.8 0 11 10.5 08/01/2005 15:40:00 5.6 0.5 6.8 3.8 5.3 0.5 6.5 4.2 234 7 235 305 10.8 0 11 10.5 08/01/2005 15:50:00 5.4 0.5 6.5 3.8 5.1 0.5 6.5 3.8 233 6 231 305 10.9 0 11 10.8 08/01/2005 16:00:00 5.4 0.6 6.8 3.8 5.1 0.6 6.5 3.4 231 5 231 305 10.8 0 11 10.8 08/01/2005 16:10:00 5.9 0.6 7.2 4.2 5.6 0.7 6.8 3.8 238 6 232 305 10.9 0 11 10.5 08/01/2005 16:20:00 5.6 0.6 6.8 3.8 5.3 0.5 6.5 3.8 236 6 252 305 10.8 0.2 11.3 10.5 08/01/2005 16:30:00 5.9 0.6 6.8 4.2 5.5 0.6 6.8 3.8 229 7 238 305 10.8 0 11 10.5 08/01/2005 16:40:00 6 0.6 7.2 4.2 5.7 0.6 6.8 4.2 231 6 234 305 10.8 0 11 10.5 08/01/2005 16:50:00 6.1 0.5 7.2 4.6 5.8 0.6 7.2 3.8 231 5 234 305 10.7 0 11 10.5 08/01/2005 17:00:00 6.1 0.5 7.2 4.6 5.8 0.6 6.8 4.6 226 5 227 305 10.8 0 11 10.5 08/01/2005 17:10:00 6.2 0.4 6.8 4.6 5.9 0.5 6.8 4.6 232 6 231 305 10.6 0 10.8 10.5 08/01/2005 17:20:00 5.9 0.6 7.2 4.6 5.8 0.6 7.6 4.2 231 7 231 305 10.8 0 11 10.5 08/01/2005 17:30:00 5.7 0.6 7.2 4.2 5.4 0.5 6.5 4.2 233 6 242 305 10.8 0 11 10.5 08/01/2005 17:40:00 6 0.7 7.2 4.2 5.7 0.7 7.2 4.2 226 5 227 305 10.8 0 11 10.5 08/01/2005 17:50:00 6.4 0.5 7.2 4.9 6.1 0.5 7.2 4.6 231 5 225 305 10.6 0 10.8 10.5 08/01/2005 18:00:00 6 0.5 7.6 4.6 5.7 0.6 7.2 4.2 231 5 226 305 10.4 0 10.5 10.2 08/01/2005 18:10:00 6.1 0.5 7.2 4.6 5.8 0.5 7.2 4.2 229 5 223 305 10.5 0 10.8 10.2 08/01/2005 18:20:00 5.8 0.6 6.8 4.2 5.6 0.6 6.8 4.6 232 5 227 305 10.4 0 10.5 10.2 08/01/2005 18:30:00 5.7 0.7 6.8 3.8 5.4 0.7 6.8 3.8 228 5 225 305 10.4 0 10.5 10.2 08/01/2005 18:40:00 5.8 0.6 6.8 4.2 5.5 0.6 6.5 3.8 230 6 231 305 10.5 0 10.8 10.2 08/01/2005 18:50:00 5.4 0.6 6.8 3.4 5.1 0.6 6.5 3.4 230 6 227 305 10.6 0 10.8 10.2 08/01/2005 19:00:00 5.7 0.5 6.8 3.8 5.4 0.6 6.5 3.4 226 5 217 305 10.4 0 10.5 10.2 08/01/2005 19:10:00 5.7 0.5 6.8 4.2 5.4 0.5 6.5 3.8 222 5 221 305 10.6 0 10.8 10.5 08/01/2005 19:20:00 5.4 0.7 6.8 3.4 5.2 0.8 6.8 3 223 6 223 305 10.6 0 10.8 10.5 08/01/2005 19:30:00 5.3 0.5 6.5 4.2 5 0.6 6.5 3.4 222 5 220 305 10.8 0 10.8 10.5 08/01/2005 19:40:00 5.5 0.5 6.5 4.2 5.3 0.5 6.5 3.8 222 6 214 305 10.6 0 10.8 10.5 08/01/2005 19:50:00 5.6 0.5 6.5 3.8 5.3 0.6 6.5 3.4 217 5 213 305 10.6 0 10.8 10.5 08/01/2005 20:00:00 5.1 0.6 7.2 3.8 4.9 0.6 6.8 3 223 8 229 305 10.5 0 10.8 10.2 08/01/2005 20:10:00 4.9 0.6 6.5 3 4.7 0.7 6.1 2.6 216 6 216 305 10.5 0 10.8 10.2 08/01/2005 20:20:00 4.7 0.5 5.7 3 4.5 0.5 5.7 3 222 8 221 305 10.4 0 10.5 10.2 08/01/2005 20:30:00 4.6 0.6 6.1 3 4.3 0.6 5.7 2.6 226 6 218 305 10.5 0 10.8 10.2 08/01/2005 20:40:00 5 0.4 5.7 3.8 4.7 0.5 5.7 3.4 218 6 230 305 10.6 0 10.8 10.5 08/01/2005 20:50:00 4.9 0.5 6.1 3.4 4.7 0.5 6.1 3.4 218 6 224 305 10.5 0 10.8 10.5 08/01/2005 21:00:00 4.9 0.5 6.1 3.4 4.5 0.5 5.7 3 221 10 221 305 10.5 0 10.8 10.2 08/01/2005 21:10:00 4.5 0.5 5.7 3 4.3 0.6 5.7 3 219 8 219 305 10.4 0 10.5 10.2 08/01/2005 21:20:00 4.6 0.5 5.7 3 4.3 0.5 5.7 3 213 6 207 305 10.3 0 10.5 10.2 08/01/2005 21:30:00 5.1 0.7 6.8 3 4.8 0.7 6.5 3 212 6 218 305 10.2 0 10.5 10 08/01/2005 21:40:00 5.3 0.5 6.5 3.8 5.2 0.5 6.5 3.4 209 5 208 305 9.9 0 10.5 9.7 08/01/2005 21:50:00 5.2 0.6 6.5 3.4 5.1 0.7 6.5 3 209 6 208 305 9.9 0.1 10.2 9.7 08/01/2005 22:00:00 5.3 0.5 6.5 4.2 5.1 0.5 6.5 3.4 210 6 211 305 9.8 0 10.2 9.7 08/01/2005 22:10:00 5 0.6 6.5 3.4 4.8 0.6 6.5 3 212 6 218 305 9.9 0 10.2 9.7 08/01/2005 22:20:00 5.3 0.8 6.8 3 4.9 0.8 6.5 3.4 215 8 214 305 10 0 10 9.7 08/01/2005 22:30:00 5.4 0.6 6.8 3.8 5 0.6 6.5 3.4 214 8 212 305 10 0 10.2 10 08/01/2005 22:40:00 5.2 0.8 6.5 3 4.8 0.8 6.5 3 219 9 223 305 10 0 10.2 10 08/01/2005 22:50:00 5.4 0.6 6.8 3.8 5.1 0.6 6.5 3.4 215 7 221 305 9.9 0 10 9.7 08/01/2005 23:00:00 5.1 0.6 6.8 3.4 4.7 0.6 6.5 3.4 220 6 221 305 9.9 0 10 10 08/01/2005 23:10:00 4.9 0.8 6.5 3.4 4.6 0.8 6.5 3 215 7 231 305 10 0 10.2 10 08/01/2005 23:20:00 4.7 0.6 6.1 3.4 4.4 0.6 5.7 2.6 215 12 227 305 9.9 0 10 9.7 08/01/2005 23:30:00 4.6 0.6 5.7 3 4.3 0.6 5.3 2.6 225 6 221 305 10 0 10.2 10 08/01/2005 23:40:00 4.6 0.5 5.7 3.8 4.4 0.5 5.3 3 218 4 218 305 10 0 10.2 10 08/01/2005 23:50:00 3.8 0.5 4.9 2.3 3.6 0.5 5.3 2.3 213 7 223 305 10.2 0 10.2 10 08/02/2005 00:00:00 4.2 0.5 5.3 3 4 0.5 5.3 2.6 215 6 208 305 10.3 0 10.8 10.2 08/02/2005 00:10:00 4.3 0.4 5.3 3 4.1 0.5 5.3 2.6 215 6 214 305 10.2 0 10.2 10.2 08/02/2005 00:20:00 4.4 0.4 5.3 3 4.3 0.5 5.3 3 208 5 208 305 10.2 0 10.2 10.2 08/02/2005 00:30:00 4.7 0.4 5.7 3.4 4.6 0.5 5.7 3 200 6 210 305 10.2 0 10.5 10 08/02/2005 00:40:00 5.1 0.4 6.1 3.8 5 0.4 6.1 3.8 197 4 200 305 10 0 10.5 10 08/02/2005 00:50:00 5.1 0.4 6.1 3.4 5 0.5 6.1 3.8 198 5 193 305 10.1 0 10.5 10 08/02/2005 01:00:00 5.2 0.5 6.5 3.4 5 0.5 6.1 3.4 198 5 203 305 10.2 0 10.5 10 08/02/2005 01:10:00 5.3 0.5 6.5 3.8 5.2 0.5 6.1 3.8 199 5 194 305 10.2 0 10.5 10 08/02/2005 01:20:00 5.8 0.4 6.8 4.6 5.7 0.5 6.8 4.2 200 4 197 305 10.1 0 10.5 10 08/02/2005 01:30:00 5.6 0.4 6.5 4.6 5.5 0.4 6.5 4.2 198 4 191 305 10 0 10.2 10 08/02/2005 01:40:00 5.4 0.4 6.1 3.8 5.2 0.5 6.1 3.8 197 4 200 305 10 0.1 10.2 10 08/02/2005 01:50:00 5.1 0.5 6.1 3.8 5 0.6 6.1 3 199 4 197 305 10 0 10.2 10 08/02/2005 02:00:00 5.1 0.5 6.1 3.8 5 0.6 6.1 3 198 4 202 305 10 0 10.2 10 08/02/2005 02:10:00 5.2 0.4 6.1 4.2 5.1 0.5 6.1 3.4 200 4 201 305 10 0 10.2 10 08/02/2005 02:20:00 5 0.4 6.1 3.8 4.9 0.5 5.7 3.8 203 5 207 305 10 0.1 10.2 9.7 08/02/2005 02:30:00 4.7 0.5 5.7 3.4 4.6 0.5 5.7 3 204 6 198 305 9.9 0.1 10.2 9.7 08/02/2005 02:40:00 4.8 0.4 5.7 3.8 4.8 0.4 5.7 3.4 203 6 198 305 9.9 0.1 10.2 9.7 08/02/2005 02:50:00 4.6 0.4 5.7 3.4 4.5 0.4 5.3 3.4 198 5 203 305 9.7 0 10.2 9.7 08/02/2005 03:00:00 4.4 0.3 4.9 3.4 4.4 0.3 4.9 3.4 202 4 198 305 9.7 0 9.7 9.7 08/02/2005 03:10:00 4.1 0.4 4.9 2.6 4 0.4 4.9 3 197 6 192 305 9.7 0 10 9.7 08/02/2005 03:20:00 3.3 0.5 4.6 1.5 3.4 0.5 4.6 2.3 190 7 194 305 9.8 0 10 9.7 08/02/2005 03:30:00 3.7 0.5 4.6 2.3 3.8 0.5 4.9 2.3 189 6 190 305 9.7 0 10 9.7 08/02/2005 03:40:00 3.6 0.5 4.9 2.3 3.8 0.5 4.6 2.6 189 6 197 305 9.8 0 10 9.7 08/02/2005 03:50:00 4.2 0.6 5.7 2.6 4.1 0.6 5.3 2.6 203 8 199 305 9.9 0 10.2 9.7 08/02/2005 04:00:00 4.8 0.4 6.1 3.8 4.8 0.5 5.7 3.8 203 4 203 305 9.9 0 10.2 9.7 08/02/2005 04:10:00 4.5 0.5 5.7 3 4.4 0.5 5.7 3 204 7 206 305 9.9 0.1 10.5 9.7 08/02/2005 04:20:00 4.8 0.3 5.7 3.8 4.8 0.4 5.7 3.4 200 4 192 305 9.9 0 10.2 9.7 08/02/2005 04:30:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3 196 5 198 305 9.8 0 10.2 9.7 08/02/2005 04:40:00 4.2 0.4 5.3 3 4.1 0.5 4.9 3 194 5 197 305 10 0 10.2 10 08/02/2005 04:50:00 4 0.4 4.9 2.6 4.1 0.4 4.9 3 191 6 194 305 9.9 0 10.2 10 08/02/2005 05:00:00 4.8 0.4 5.3 3 4.7 0.5 5.7 2.6 200 4 197 305 10 0 10.5 10 08/02/2005 05:10:00 4.9 0.3 5.7 4.2 4.8 0.5 5.7 3.4 200 4 202 305 9.9 0.1 10.2 9.7 08/02/2005 05:20:00 4.5 0.4 5.3 3.4 4.5 0.4 5.3 3 201 4 202 305 9.9 0.1 10.2 9.7 08/02/2005 05:30:00 4.2 0.3 5.3 3.4 4.1 0.4 4.9 3 199 5 203 305 9.9 0.1 10.2 9.7 08/02/2005 05:40:00 4.1 0.4 5.3 3 3.9 0.4 4.9 2.6 197 6 198 305 10 0.1 10.5 9.7 08/02/2005 05:50:00 3.8 0.5 5.3 2.3 3.8 0.4 4.9 3 191 8 196 305 9.9 0.1 10.2 9.7 08/02/2005 06:00:00 4 0.6 5.7 2.6 4.2 0.5 5.7 3 187 6 194 305 9.9 0.1 10.2 9.7 08/02/2005 06:10:00 4 0.6 5.3 2.6 4 0.5 5.3 2.6 191 8 208 305 9.9 0.1 10.2 9.7 08/02/2005 06:20:00 4.8 0.4 5.3 3.8 4.8 0.4 5.7 3.4 200 6 191 305 9.9 0 10.2 9.7 08/02/2005 06:30:00 4.9 0.5 5.7 3.4 4.9 0.5 5.7 3 201 5 203 305 9.8 0 10.2 9.7 08/02/2005 06:40:00 4.6 0.4 5.7 3 4.6 0.5 5.7 3 194 6 192 305 9.9 0.1 10.2 9.7 08/02/2005 06:50:00 4.6 0.4 5.3 3 4.5 0.5 5.3 3 193 6 196 305 9.9 0.1 10.2 9.7 08/02/2005 07:00:00 5 0.3 5.7 3.8 5 0.4 5.7 3.8 193 4 194 305 9.8 0 10.2 9.7 08/02/2005 07:10:00 5 0.3 5.7 3.8 5 0.5 5.7 3.4 196 4 193 305 9.8 0 10.2 9.7 08/02/2005 07:20:00 5.2 0.3 5.7 3.8 5.2 0.4 6.1 3.8 198 4 198 305 9.7 0 10.2 9.7 08/02/2005 07:30:00 5.1 0.4 5.7 3.8 5 0.4 6.1 3.8 200 4 204 305 9.7 0 10 9.7 08/02/2005 07:40:00 5.3 0.3 6.1 4.6 5.2 0.4 6.1 3.8 198 4 196 305 9.7 0 9.7 9.7 08/02/2005 07:50:00 4.6 0.5 6.1 3 4.7 0.5 5.7 3 190 5 196 305 9.7 0 10 9.7 08/02/2005 08:00:00 4.2 0.6 5.3 2.3 4.3 0.6 5.3 2.6 188 6 185 305 9.8 0 10.2 9.7 08/02/2005 08:10:00 4.3 0.5 5.3 2.6 4.2 0.5 5.3 3 193 7 194 305 9.9 0 10.2 9.7 08/02/2005 08:20:00 4.4 0.5 5.7 3 4.3 0.5 5.3 3 200 5 200 305 9.8 0 10 9.7 08/02/2005 08:30:00 4.3 0.3 4.9 3 4.2 0.4 5.3 3 195 5 198 305 9.9 0 10.2 9.7 08/02/2005 08:40:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3 194 4 194 305 10 0 10.2 10 08/02/2005 08:50:00 4.8 0.4 5.7 4.2 4.7 0.5 5.7 3 199 5 196 305 10.2 0 10.5 10 08/02/2005 09:00:00 4.8 0.4 5.7 3.8 4.6 0.4 5.7 3.4 199 5 198 305 10.3 0 10.8 10.2 08/02/2005 09:10:00 4.9 0.4 5.7 3.4 4.8 0.5 5.7 3.4 195 5 198 305 10.4 0.1 11 10.2 08/02/2005 09:20:00 4.2 0.4 5.3 3 3.8 0.5 4.9 2.6 210 6 215 305 10.6 0 11 10.5 08/02/2005 09:30:00 3.9 0.4 4.9 2.6 3.6 0.5 4.6 2.3 210 6 210 305 10.6 0 10.8 10.5 08/02/2005 09:40:00 4 0.3 4.6 3 3.7 0.4 4.6 2.6 204 5 208 305 10.6 0 11 10.5 08/02/2005 09:50:00 4.3 0.4 4.9 3.4 4.2 0.5 4.9 3 199 3 196 305 10.8 0 11.3 10.5 08/02/2005 10:00:00 4.3 0.3 4.9 3 4.2 0.4 4.9 3 196 4 190 305 10.9 0 11 10.8 08/02/2005 10:10:00 4.1 0.3 4.9 3 4 0.4 4.9 2.6 204 5 203 305 11 0 11 10.8 08/02/2005 10:20:00 4.1 0.3 4.9 2.6 4 0.4 4.6 2.6 206 5 208 305 11.1 0 11.3 11 08/02/2005 10:30:00 3.9 0.4 4.6 2.6 3.8 0.4 4.6 2.6 206 5 204 305 11.2 0 11.3 11 08/02/2005 10:40:00 4 0.4 4.9 3 3.9 0.5 4.9 2.6 207 5 205 305 11.4 0 11.6 11.3 08/02/2005 10:50:00 4 0.5 4.9 2.6 3.9 0.5 4.9 2.6 211 6 210 305 11.6 0 11.8 11.3 08/02/2005 11:00:00 3.9 0.4 4.9 2.6 3.7 0.5 4.9 2.3 212 6 217 305 11.4 0 11.6 11.3 08/02/2005 11:10:00 4.2 0.5 5.3 2.6 4 0.5 4.9 2.6 212 6 208 305 11.4 0 11.6 11.3 08/02/2005 11:20:00 4 0.5 5.3 2.3 3.6 0.5 4.9 2.3 213 6 211 305 11.6 0 11.8 11.3 08/02/2005 11:30:00 3.8 0.5 4.9 2.6 3.6 0.5 4.6 2.3 217 7 209 305 11.6 0 11.8 11.3 08/02/2005 11:40:00 4 0.4 4.9 2.6 3.8 0.4 4.9 2.6 220 5 220 305 11.4 0 11.6 11.3 08/02/2005 11:50:00 3.6 0.4 4.6 2.3 3.5 0.4 4.6 2.3 216 7 205 305 11.4 0 11.3 11 08/02/2005 12:00:00 3.2 0.4 4.2 2.3 3.1 0.5 4.2 1.5 208 8 222 305 11.4 0 11.6 11 08/02/2005 12:10:00 3 0.3 3.8 1.9 3 0.3 3.8 1.9 202 6 207 305 11.2 0 11.3 11 08/02/2005 12:20:00 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.5 200 6 196 305 11 0 11.3 10.8 08/02/2005 12:30:00 3 0.3 3.8 2.3 3 0.4 3.8 1.9 203 6 213 305 11 0 11 10.8 08/02/2005 12:40:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 206 8 211 305 11.2 0 11.3 11 08/02/2005 12:50:00 3 0.3 3.8 1.9 3 0.4 4.2 1.9 205 6 208 305 11.2 0 11.3 11 08/02/2005 13:00:00 3.3 0.4 4.2 2.3 3.3 0.3 4.2 2.3 207 7 202 305 11.4 0 11.6 11 08/02/2005 13:10:00 3.6 0.4 4.6 2.3 3.5 0.5 4.6 2.3 212 7 214 305 11.6 0 11.6 11.3 08/02/2005 13:20:00 3.5 0.4 4.6 2.6 3.5 0.4 4.6 2.3 211 6 205 305 11.4 0 11.6 11.3 08/02/2005 13:30:00 3.5 0.4 4.6 2.3 3.3 0.5 4.6 1.9 211 8 214 305 11.5 0.1 11.8 11.3 08/02/2005 13:40:00 3.7 0.3 4.6 2.6 3.6 0.3 4.6 2.6 207 5 213 305 11.4 0 11.6 11.3 08/02/2005 13:50:00 3.6 0.4 4.6 2.3 3.6 0.4 4.6 2.3 208 7 217 305 11.3 0 11.3 11 08/02/2005 14:00:00 3.5 0.4 4.2 2.6 3.4 0.4 4.2 1.9 206 6 216 305 11.2 0 11.6 11 08/02/2005 14:10:00 3.4 0.4 4.2 1.9 3.3 0.4 4.2 1.5 208 7 222 305 11.4 0 11.6 11.3 08/02/2005 14:20:00 3.1 0.4 3.8 2.3 3 0.4 3.8 1.9 204 7 196 305 11.4 0 11.6 11.3 08/02/2005 14:30:00 3.1 0.4 3.8 2.3 3 0.4 3.8 1.5 206 7 205 305 11.6 0 11.6 11.3 08/02/2005 14:40:00 3.4 0.5 4.6 2.3 3.3 0.6 4.6 1.5 208 9 211 305 11.7 0 11.8 11.3 08/02/2005 14:50:00 3.3 0.5 4.9 2.3 3.2 0.5 4.9 1.9 208 10 208 305 11.3 0 11.6 11 08/02/2005 15:00:00 3.4 0.4 4.2 2.3 3.2 0.5 4.6 1.5 207 7 210 305 11.3 0 11.3 11 08/02/2005 15:10:00 3.1 0.4 4.2 2.3 3 0.4 3.8 1.9 211 9 215 305 11.3 0 11.6 11 08/02/2005 15:20:00 3.1 0.4 4.2 2.3 3.1 0.4 3.8 1.9 208 8 218 305 11.2 0 11.3 11 08/02/2005 15:30:00 2.9 0.4 4.2 1.9 2.9 0.4 3.8 1.9 210 7 208 305 11.2 0 11.3 11 08/02/2005 15:40:00 3.2 0.4 4.2 2.3 3 0.5 4.2 1.5 214 8 215 305 11.2 0 11.3 11 08/02/2005 15:50:00 3.4 0.3 4.2 2.6 3.3 0.4 4.2 2.3 213 8 202 305 11.3 0 11.3 11 08/02/2005 16:00:00 3.2 0.4 4.2 2.3 3.1 0.5 4.2 1.1 207 8 210 305 11 0 11.3 11 08/02/2005 16:10:00 2.9 0.4 3.8 1.5 2.9 0.4 3.8 1.5 208 7 210 305 11.1 0 11.3 11 08/02/2005 16:20:00 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.5 209 9 203 305 11 0 11.3 11 08/02/2005 16:30:00 3.1 0.4 3.8 1.5 3 0.4 3.8 1.5 205 8 190 305 11.2 0 11.3 11 08/02/2005 16:40:00 3.3 0.4 4.2 2.3 3.2 0.4 4.2 1.9 216 8 220 305 11 0 11 11 08/02/2005 16:50:00 3.3 0.4 4.2 2.6 3.3 0.4 4.2 2.3 207 8 203 305 11 0 11.3 10.8 08/02/2005 17:00:00 3.4 0.4 4.2 2.3 3.3 0.4 4.2 2.3 211 7 202 305 11 0 11 10.8 08/02/2005 17:10:00 3.5 0.5 4.6 1.5 3.3 0.5 4.2 1.5 212 8 213 305 10.9 0 11 10.8 08/02/2005 17:20:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.5 211 9 202 305 10.9 0 11 10.8 08/02/2005 17:30:00 2.6 0.4 3.8 1.5 2.5 0.3 3.4 1.5 219 7 218 305 10.9 0 11 10.8 08/02/2005 17:40:00 2.8 0.4 3.8 1.9 2.6 0.4 3.8 1.5 216 9 211 305 10.9 0 11 10.8 08/02/2005 17:50:00 3 0.5 4.2 1.5 2.9 0.5 3.8 1.1 216 9 210 305 11 0 11 10.8 08/02/2005 18:00:00 2.8 0.4 3.8 1.9 2.6 0.4 3.8 1.5 215 8 224 305 10.8 0 11 10.8 08/02/2005 18:10:00 2.7 0.4 3.8 1.5 2.6 0.4 3.8 1.5 220 9 231 305 10.8 0 10.8 10.5 08/02/2005 18:20:00 2.8 0.3 3.4 1.9 2.7 0.3 3.4 1.9 230 9 214 305 10.6 0 10.8 10.5 08/02/2005 18:30:00 2.5 0.4 3.4 1.5 2.5 0.4 3.8 1.5 227 9 225 305 10.6 0 10.8 10.2 08/02/2005 18:40:00 2 0.4 3 1.1 1.9 0.3 2.6 0.7 219 9 224 305 10.8 0 10.8 10.5 08/02/2005 18:50:00 1.6 0.3 2.3 0.7 1.5 0.3 2.6 0.4 217 9 205 305 10.8 0 11 10.8 08/02/2005 19:00:00 2.1 0.4 3 1.1 2.1 0.4 3 1.5 220 8 215 305 10.8 0 11 10.8 08/02/2005 19:10:00 2.1 0.4 3 1.1 2.1 0.4 3 1.1 227 11 235 305 10.8 0 10.8 10.5 08/02/2005 19:20:00 2.1 0.4 3 0.7 1.9 0.3 3 1.1 222 10 215 305 10.8 0 10.8 10.8 08/02/2005 19:30:00 2.2 0.4 3 1.1 2 0.5 3 0.7 229 13 248 305 10.8 0 10.8 10.5 08/02/2005 19:40:00 2.2 0.4 3 1.1 2.1 0.4 2.6 1.1 222 6 218 305 10.8 0 11 10.8 08/02/2005 19:50:00 2.7 0.4 3.4 1.9 2.6 0.4 3.8 1.5 222 9 221 305 10.8 0 11 10.5 08/02/2005 20:00:00 2.8 0.4 3.8 1.5 2.7 0.4 3.4 1.9 228 8 234 305 10.8 0 11 10.5 08/02/2005 20:10:00 3.1 0.3 3.8 2.3 2.9 0.4 4.2 1.9 226 8 219 305 10.4 0 10.5 10.2 08/02/2005 20:20:00 3 0.3 3.8 2.3 2.9 0.4 3.8 1.9 221 6 224 305 10.4 0 10.8 10.2 08/02/2005 20:30:00 3.3 0.4 4.6 2.3 3.1 0.4 4.2 2.3 218 7 221 305 10.6 0 10.8 10.5 08/02/2005 20:40:00 3.7 0.4 4.6 2.6 3.6 0.4 4.6 2.6 220 6 218 305 10.6 0 10.8 10.5 08/02/2005 20:50:00 3.4 0.4 4.6 2.6 3.2 0.4 4.2 1.9 221 8 236 305 10.5 0 10.8 10.2 08/02/2005 21:00:00 3.3 0.3 4.2 2.3 3.2 0.4 4.2 1.9 218 6 224 305 10.5 0 10.5 10.2 08/02/2005 21:10:00 3 0.4 4.2 1.9 2.8 0.4 4.2 1.5 221 8 220 305 10.4 0 10.5 10.2 08/02/2005 21:20:00 2.4 0.4 3.4 1.1 2.3 0.4 3.4 1.1 213 9 211 305 10.3 0 10.5 10.2 08/02/2005 21:30:00 2.3 0.3 3 1.1 2.3 0.3 3 1.1 214 6 214 305 10.3 0 10.5 10.2 08/02/2005 21:40:00 1.8 0.3 2.6 1.1 1.7 0.4 2.3 0.4 205 6 213 305 10.3 0 10.5 10.2 08/02/2005 21:50:00 2 0.4 2.6 0.7 1.9 0.3 2.6 0.7 214 6 213 305 10.4 0 10.8 10.2 08/02/2005 22:00:00 2.2 0.3 3 1.1 2.1 0.4 3 0.7 213 7 214 305 10.4 0 10.8 10.2 08/02/2005 22:10:00 2 0.3 3 1.5 1.9 0.3 3 1.1 223 6 223 305 10.4 0 10.8 10.2 08/02/2005 22:20:00 1.9 0.3 2.6 1.1 1.8 0.3 2.6 1.1 229 8 237 305 10.3 0 11 10.2 08/02/2005 22:30:00 1.6 0.3 2.3 0.4 1.4 0.3 1.9 0.4 205 8 213 305 10.3 0 10.5 10.2 08/02/2005 22:40:00 1.4 0.3 1.9 0.7 1.3 0.2 1.9 0.7 201 4 198 305 10.3 0 10.5 10.2 08/02/2005 22:50:00 1.9 0.3 2.6 1.1 1.7 0.3 2.3 1.1 203 6 210 305 10.3 0 10.8 10.2 08/02/2005 23:00:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 202 6 202 305 10.3 0 10.8 10.2 08/02/2005 23:10:00 2.4 0.3 3 1.5 2.3 0.3 3 1.5 200 8 197 305 10.4 0.1 10.8 10.2 08/02/2005 23:20:00 2.7 0.4 3.4 1.5 2.8 0.4 3.8 1.5 188 5 191 305 10.4 0.1 10.8 10.2 08/02/2005 23:30:00 2.8 0.3 3.8 1.9 2.8 0.3 3.4 2.3 195 7 193 305 10.4 0.1 10.8 10.2 08/02/2005 23:40:00 2.6 0.3 3.4 1.9 2.5 0.3 3.4 1.5 206 8 204 305 10.4 0.1 10.8 10.2 08/02/2005 23:50:00 2 0.4 3 0.7 1.9 0.5 3 0.7 197 8 190 305 10.4 0.1 11 10.2 08/03/2005 00:00:00 1.8 0.2 2.6 1.1 1.7 0.3 2.3 0.7 210 6 213 305 10.4 0.1 11 10.2 08/03/2005 00:10:00 2.3 0.3 3 1.5 2.2 0.2 2.6 1.5 220 4 218 305 10.3 0.1 10.8 10.2 08/03/2005 00:20:00 2.2 0.3 2.6 1.5 2.1 0.3 2.6 1.5 219 6 218 305 10.3 0 10.8 10.2 08/03/2005 00:30:00 2.2 0.3 3 1.5 2.1 0.3 2.6 1.5 227 6 230 305 10.3 0 10.8 10.2 08/03/2005 00:40:00 2 0.4 2.6 1.1 1.9 0.4 2.6 0.7 224 5 237 305 10.2 0 10.8 10 08/03/2005 00:50:00 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 194 15 221 305 10.2 0 10.8 10 08/03/2005 01:00:00 1 0.8 3 0.4 1.2 1 3.8 0.4 178 15 159 305 10.2 0 10.8 10.2 08/03/2005 01:10:00 1.9 0.3 2.6 1.5 1.9 0.3 2.6 1.5 136 7 151 305 10.3 0 10.8 10.2 08/03/2005 01:20:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 1.1 129 8 124 305 10.3 0 10.8 10.2 08/03/2005 01:30:00 1.7 0.8 3.4 0.4 2 0.6 3.4 0.4 162 13 158 305 10.3 0 10.8 10.2 08/03/2005 01:40:00 1.4 0.4 2.6 0.4 1.6 0.4 2.3 0.7 159 5 151 305 10.2 0 10.2 10 08/03/2005 01:50:00 0.9 0.3 1.9 0.4 1.3 0.3 2.3 0.4 170 6 156 305 10.1 0 10.2 10 08/03/2005 02:00:00 1.3 0.4 1.9 0.4 1.5 0.5 2.6 0.4 163 3 165 305 10.1 0 10.2 10 08/03/2005 02:10:00 1.7 0.3 2.6 1.1 1.6 0.3 2.6 0.7 143 7 156 305 10.1 0 10.2 10 08/03/2005 02:20:00 1.7 0.5 2.6 0.4 1.9 0.4 2.6 1.1 154 7 149 305 10.1 0 10.2 10 08/03/2005 02:30:00 2.2 0.6 3.4 0.4 2.2 0.6 3 0.7 137 9 129 305 10.1 0 10.2 10 08/03/2005 02:40:00 2.1 0.7 3.4 0.4 2.1 0.7 3.4 0.7 125 9 131 305 10.1 0 10.2 10 08/03/2005 02:50:00 3.7 0.5 4.6 2.3 3.7 0.5 4.6 2.3 137 6 145 305 9.9 0 10.2 9.7 08/03/2005 03:00:00 3.3 0.3 4.2 2.6 3.4 0.3 4.2 2.3 129 6 139 305 9.7 0 10.2 9.7 08/03/2005 03:10:00 3.2 0.6 4.2 1.9 3.4 0.5 4.6 1.9 141 9 135 305 9.7 0 10.2 9.7 08/03/2005 03:20:00 3.5 0.6 4.6 1.5 3.6 0.4 4.6 2.3 148 6 146 305 9.7 0 10.2 9.7 08/03/2005 03:30:00 3 0.5 4.2 1.1 3.4 0.5 4.2 1.9 151 9 147 305 9.7 0 10.2 9.7 08/03/2005 03:40:00 2.7 0.5 4.2 1.1 2.8 0.5 3.8 1.5 152 9 147 305 9.8 0 10.2 9.7 08/03/2005 03:50:00 2.6 0.5 3.8 1.5 2.8 0.4 3.8 1.9 158 8 150 305 10 0 10.5 9.7 08/03/2005 04:00:00 2 0.5 3 0.7 2.4 0.4 3.4 1.5 166 11 161 305 10 0 10.5 10 08/03/2005 04:10:00 1.8 0.5 3.4 0.7 2.3 0.4 3 1.1 168 9 154 305 9.9 0.1 10.5 10 08/03/2005 04:20:00 2.6 0.4 3.4 1.1 2.9 0.3 3.4 2.3 155 6 148 305 9.9 0 10.2 9.7 08/03/2005 04:30:00 3 0.4 3.8 1.9 3.1 0.3 3.8 2.3 155 6 151 305 9.8 0 10.2 9.7 08/03/2005 04:40:00 2.7 0.5 3.8 1.1 3.1 0.3 4.2 2.3 160 8 155 305 9.8 0 10.2 9.7 08/03/2005 04:50:00 2.4 0.5 3.8 1.1 2.9 0.4 4.2 1.9 169 11 183 305 9.9 0.1 10.5 9.7 08/03/2005 05:00:00 1.9 0.6 3.4 0.7 2.4 0.4 3.4 1.5 175 8 188 305 10.2 0 10.8 10 08/03/2005 05:10:00 2.3 0.6 3.4 1.1 2.7 0.4 3.8 1.5 180 8 189 305 10.3 0 10.8 10.2 08/03/2005 05:20:00 2.9 0.5 3.8 1.5 3.1 0.4 4.2 2.3 184 5 183 305 10.4 0.1 10.8 10.2 08/03/2005 05:30:00 3.5 0.4 4.6 2.6 3.4 0.4 4.2 2.3 193 6 195 305 10.4 0.1 10.8 10.2 08/03/2005 05:40:00 3.1 0.5 4.6 1.5 3.1 0.4 4.6 1.9 197 8 192 305 10.3 0 10.8 10.2 08/03/2005 05:50:00 2.6 0.4 3.8 1.5 2.7 0.4 3.8 1.9 192 9 186 305 10.3 0 10.8 10.2 08/03/2005 06:00:00 1.7 0.5 3 0.4 2.1 0.4 3 1.1 171 10 189 305 10.3 0 10.8 10.2 08/03/2005 06:10:00 1.3 0.5 2.6 0.4 1.7 0.4 2.6 0.4 173 13 167 305 10.2 0 10.2 10.2 08/03/2005 06:20:00 1.1 0.5 2.3 0.4 1.4 0.5 2.3 0.4 159 9 156 305 10.2 0 10.2 10.2 08/03/2005 06:30:00 1.3 0.4 2.6 0.4 1.8 0.3 2.6 1.1 177 9 186 305 10.3 0 10.2 10.2 08/03/2005 06:40:00 2.8 0.7 4.6 1.1 3.4 0.6 4.2 1.5 182 6 191 305 10.3 0 10.5 10.2 08/03/2005 06:50:00 2.3 0.5 3.4 1.1 2.7 0.4 3.4 1.9 163 11 185 305 10.3 0 10.8 10.2 08/03/2005 07:00:00 2.1 0.4 3.4 1.1 2.8 0.5 3.8 1.1 169 6 158 305 10.1 0 10.5 10 08/03/2005 07:10:00 1.9 0.4 3 0.7 2.5 0.4 3.4 1.5 176 9 208 305 10.1 0 10.2 10 08/03/2005 07:20:00 2.1 0.6 3.8 1.1 2.8 0.4 3.8 1.5 179 6 187 305 10.1 0 10.5 10 08/03/2005 07:30:00 2.5 0.5 3.8 1.1 3 0.5 4.2 1.5 173 12 183 305 10 0 10.2 10 08/03/2005 07:40:00 2 0.5 3 0.7 2 0.4 3 1.1 152 5 160 305 10 0 10.2 10 08/03/2005 07:50:00 2.2 0.6 3.4 0.7 2.3 0.5 3 1.1 159 7 156 305 10.2 0 10.5 10 08/03/2005 08:00:00 2.8 0.5 4.2 1.5 2.9 0.5 4.2 1.9 148 7 152 305 10.2 0 10.2 10.2 08/03/2005 08:10:00 3.7 0.4 4.6 2.6 3.7 0.4 4.6 2.3 141 8 147 305 10.2 0 10.2 10 08/03/2005 08:20:00 3.9 0.5 4.9 2.6 3.9 0.5 4.9 2.3 144 6 151 305 10.2 0 10.5 10 08/03/2005 08:30:00 4.1 0.4 4.9 2.6 4.1 0.3 4.6 3 149 6 155 305 10.2 0 10.5 10 08/03/2005 08:40:00 3.7 0.5 4.9 2.3 3.7 0.4 4.9 2.6 153 5 155 305 10.3 0 10.8 10.2 08/03/2005 08:50:00 3.4 0.6 4.6 1.5 3.5 0.5 4.6 1.9 157 7 158 305 10.4 0.1 10.8 10.2 08/03/2005 09:00:00 2.5 0.6 3.8 1.1 3.1 0.6 5.3 1.5 171 9 165 305 10.5 0.1 11 10.5 08/03/2005 09:10:00 3.2 0.5 4.6 1.9 4.3 0.4 5.7 3 172 7 154 305 10.5 0.1 11 10.2 08/03/2005 09:20:00 3.8 0.5 5.3 2.3 4.2 0.5 5.7 3 182 5 184 305 10.7 0 11.3 10.5 08/03/2005 09:30:00 3 0.5 3.8 1.5 3.4 0.4 4.2 2.3 182 8 181 305 10.7 0 11 10.5 08/03/2005 09:40:00 2.6 0.5 3.8 1.1 3.3 0.5 4.2 2.3 178 8 176 305 10.8 0 11 10.8 08/03/2005 09:50:00 2.7 0.7 4.6 1.1 3.2 0.5 4.6 1.9 178 9 196 305 10.8 0 10.8 10.5 08/03/2005 10:00:00 2.6 0.5 3.8 1.5 2.8 0.4 3.8 1.9 186 8 188 305 10.8 0 11 10.8 08/03/2005 10:10:00 3.4 0.4 4.6 2.3 3.2 0.5 4.6 2.3 233 11 234 305 10.5 0.2 11.3 10 08/03/2005 10:20:00 2.8 0.4 3.8 1.9 2.6 0.5 3.8 1.5 238 5 234 305 10.1 0 10.2 10 08/03/2005 10:30:00 2.2 0.3 3 1.5 2.1 0.3 3 1.1 237 7 239 305 10.1 0 10.2 10 08/03/2005 10:40:00 2.2 0.4 3 1.1 2.1 0.3 3 1.5 246 7 242 305 10.2 0 10.2 10 08/03/2005 10:50:00 2.2 0.3 3 1.5 2.2 0.3 3 1.5 228 8 236 305 10.2 0 10.2 10 08/03/2005 11:00:00 1.9 0.4 2.6 0.7 1.9 0.3 2.6 1.1 222 10 228 305 10.3 0 10.5 10.2 08/03/2005 11:10:00 2.8 0.5 3.8 1.5 2.7 0.5 3.8 1.5 220 7 217 305 10.3 0 10.5 10.2 08/03/2005 11:20:00 2.5 0.3 3.4 1.5 2.4 0.4 3.4 1.5 212 9 232 305 10.4 0 10.5 10.2 08/03/2005 11:30:00 2.3 0.4 3.4 1.1 2.3 0.5 3.4 0.7 209 9 215 305 10.6 0 10.8 10.5 08/03/2005 11:40:00 2.2 0.4 3 1.1 2.1 0.4 3 1.1 218 8 220 305 10.5 0 10.8 10.5 08/03/2005 11:50:00 1.7 0.5 3 0.4 1.6 0.4 2.6 0.4 211 9 217 305 10.7 0 10.8 10.5 08/03/2005 12:00:00 1.9 0.4 3 0.4 1.9 0.4 3 0.7 196 11 204 305 10.8 0 11 10.8 08/03/2005 12:10:00 3.3 0.8 4.6 1.1 3.1 0.8 4.6 0.7 210 9 197 305 11.2 0 11.3 11 08/03/2005 12:20:00 4.1 0.6 5.3 2.6 4 0.6 5.3 2.3 217 7 225 305 11.4 0 11.3 11.3 08/03/2005 12:30:00 4.4 0.5 5.3 3 4.3 0.5 5.3 3 225 6 225 305 11.4 0 11.6 11 08/03/2005 12:40:00 3.6 0.5 5.3 2.3 3.5 0.5 4.9 2.3 231 8 234 305 11.4 0.1 11.6 11 08/03/2005 12:50:00 3.6 0.5 4.6 2.6 3.4 0.5 4.6 2.3 237 8 230 305 11.5 0 11.6 11.3 08/03/2005 13:00:00 3.4 0.4 4.6 2.3 3.3 0.4 4.6 1.9 240 8 239 305 11.6 0 11.8 11.3 08/03/2005 13:10:00 3 0.4 4.2 2.3 2.9 0.4 4.2 1.9 235 7 234 305 11.6 0 11.8 11.3 08/03/2005 13:20:00 2.3 0.4 3.4 1.1 2.2 0.5 3.4 1.1 222 11 226 305 11.5 0 11.8 11.3 08/03/2005 13:30:00 1.7 0.4 2.6 0.4 1.8 0.5 3 0.4 191 10 188 305 11.8 0 11.8 11.6 08/03/2005 13:40:00 1.9 0.4 2.6 1.1 2.1 0.3 3 1.1 191 12 189 305 11.8 0 11.8 11.6 08/03/2005 13:50:00 2.2 0.5 3.4 1.1 2.3 0.5 3.8 1.1 201 13 199 305 11.8 0 12.1 11.8 08/03/2005 14:00:00 2.6 0.4 3.8 1.5 2.5 0.5 3.8 1.1 202 11 224 305 12 0 12.1 11.8 08/03/2005 14:10:00 2.2 0.5 3.4 0.4 2.2 0.4 3.4 1.1 214 10 220 305 11.6 0 11.8 11.6 08/03/2005 14:20:00 2.4 0.3 3.8 1.5 2.4 0.4 3.8 1.5 196 9 197 305 11.8 0 11.8 11.6 08/03/2005 14:30:00 3.2 0.5 4.2 2.3 3.3 0.4 4.2 1.9 194 9 186 305 11.6 0 11.8 11.6 08/03/2005 14:40:00 3.2 0.4 4.2 2.3 3.1 0.4 4.2 1.9 202 10 215 305 11.5 0.1 11.6 11.3 08/03/2005 14:50:00 2.6 0.4 3.4 1.9 2.5 0.4 3.8 1.1 212 10 221 305 11.6 0 11.8 11.3 08/03/2005 15:00:00 2.7 0.4 4.2 1.5 2.5 0.4 3.8 1.5 214 12 197 305 11.4 0 11.6 11.3 08/03/2005 15:10:00 2.3 0.6 4.2 1.1 2.2 0.7 4.2 1.1 208 10 201 305 11.4 0 11.6 11.3 08/03/2005 15:20:00 2 0.5 3 0.7 1.8 0.5 3 0.4 213 11 217 305 11.4 0 11.6 11.3 08/03/2005 15:30:00 2 0.6 3.4 0.7 2 0.5 3 0.7 197 13 188 305 11.4 0 11.6 11.3 08/03/2005 15:40:00 2.9 0.6 4.2 1.1 2.9 0.6 4.2 0.7 195 8 202 305 11.5 0 11.6 11.3 08/03/2005 15:50:00 3.2 0.5 4.2 2.3 3.1 0.5 4.2 2.3 205 7 210 305 11.5 0 11.6 11.3 08/03/2005 16:00:00 3 0.5 4.2 1.5 3.1 0.6 4.2 1.5 194 9 194 305 11.6 0 11.8 11.3 08/03/2005 16:10:00 3.2 0.5 4.2 1.5 3.4 0.5 4.9 1.9 187 6 191 305 11.6 0.1 11.8 11.3 08/03/2005 16:20:00 3.1 0.6 4.6 1.1 3.4 0.5 4.6 2.3 184 9 189 305 11.5 0 11.8 11.3 08/03/2005 16:30:00 2.9 0.6 4.2 1.5 3.4 0.4 4.6 2.3 185 15 196 305 11.8 0 11.8 11.6 08/03/2005 16:40:00 3.5 0.4 4.2 1.9 3.4 0.5 4.2 2.3 197 9 197 305 11.6 0 11.8 11.6 08/03/2005 16:50:00 3.2 0.5 4.2 1.9 3.1 0.5 4.2 1.5 203 10 203 305 11.6 0 11.6 11.3 08/03/2005 17:00:00 3.6 0.5 5.3 1.9 3.6 0.5 4.9 2.3 196 8 205 305 11.4 0 11.6 11.3 08/03/2005 17:10:00 4.3 0.7 6.1 2.6 4 0.6 5.7 2.6 206 9 210 305 11.4 0 11.6 11.3 08/03/2005 17:20:00 4.9 0.4 6.1 3.8 4.7 0.5 5.7 3.4 206 5 202 305 11.4 0 11.3 11.3 08/03/2005 17:30:00 4.6 0.5 5.7 3.4 4.5 0.5 5.7 3.4 208 6 202 305 11.4 0 11.3 11.3 08/03/2005 17:40:00 4.2 0.6 5.7 1.9 4.1 0.6 5.7 2.3 198 8 208 305 11.5 0 11.8 11.3 08/03/2005 17:50:00 4.4 0.6 6.1 3 4.3 0.6 5.7 2.6 204 8 210 305 11.4 0 11.6 11.3 08/03/2005 18:00:00 4.7 0.6 6.1 3 4.5 0.6 5.7 3 209 6 202 305 11.4 0 11.6 11.3 08/03/2005 18:10:00 4.7 0.6 6.1 2.6 4.5 0.6 6.1 2.6 210 6 209 305 11.4 0 11.3 11.3 08/03/2005 18:20:00 4.1 0.4 5.3 3 3.9 0.5 4.9 2.6 206 6 208 305 11.4 0 11.6 11.3 08/03/2005 18:30:00 4.5 0.5 6.1 3 4.3 0.5 5.7 2.6 209 7 211 305 11.4 0 11.6 11.3 08/03/2005 18:40:00 4.9 0.5 6.5 3.8 4.9 0.5 6.5 3.4 206 8 217 305 11.4 0 11.6 11.3 08/03/2005 18:50:00 5 0.7 6.8 3 4.7 0.7 6.8 3 212 8 223 305 11.4 0 11.6 11.3 08/03/2005 19:00:00 5.9 0.6 7.6 3.8 5.3 0.7 7.2 3.4 220 7 223 305 11.4 0 11.6 11.3 08/03/2005 19:10:00 6 0.7 7.6 4.2 5.4 0.7 7.2 3.8 221 6 224 305 11.4 0 11.6 11.3 08/03/2005 19:20:00 5.8 0.6 6.8 3.4 5.3 0.6 6.8 3.8 224 6 222 305 11.2 0 11.3 11 08/03/2005 19:30:00 6.2 1 8 3.8 5.7 0.9 8 3.4 231 10 246 305 11 0 11 10.8 08/03/2005 19:40:00 6.2 0.6 7.6 4.6 5.4 0.8 7.6 3.4 245 5 250 305 10.7 0 10.8 10.5 08/03/2005 19:50:00 5.6 0.7 6.8 3.4 5.1 0.7 6.8 3.4 244 6 250 305 10.4 0 10.8 10.2 08/03/2005 20:00:00 4.7 0.5 5.7 3.4 4.2 0.5 5.3 3 238 5 242 305 10.6 0 10.8 10.5 08/03/2005 20:10:00 3.6 0.5 4.9 2.6 3.4 0.5 4.6 2.3 227 7 225 305 10.8 0 10.8 10.8 08/03/2005 20:20:00 3.4 0.4 4.2 1.9 3.3 0.4 4.2 2.3 213 8 212 305 10.8 0 11 10.8 08/03/2005 20:30:00 3.8 0.4 4.9 2.6 3.7 0.4 4.6 2.6 210 9 217 305 10.8 0 10.8 10.8 08/03/2005 20:40:00 4.1 0.3 4.9 3 3.8 0.4 4.6 2.6 217 5 217 305 10.8 0 10.8 10.8 08/03/2005 20:50:00 4.2 0.4 4.9 2.6 3.9 0.5 4.9 2.6 214 5 214 305 10.8 0 10.8 10.5 08/03/2005 21:00:00 4.3 0.5 5.3 2.6 4 0.6 4.9 2.6 213 6 213 305 10.7 0 10.8 10.5 08/03/2005 21:10:00 4.2 0.5 4.9 2.3 3.9 0.5 4.9 2.6 211 6 214 305 10.6 0 10.8 10.5 08/03/2005 21:20:00 4.4 0.5 5.7 3 4.2 0.6 5.3 2.3 209 7 210 305 10.6 0 10.8 10.5 08/03/2005 21:30:00 4.6 0.4 5.7 3.4 4.5 0.5 5.7 2.6 207 5 203 305 10.6 0 10.8 10.5 08/03/2005 21:40:00 4.5 0.4 5.3 3 4.5 0.4 5.7 3 205 8 200 305 10.6 0 10.8 10.5 08/03/2005 21:50:00 5 0.4 5.7 4.2 4.9 0.5 6.1 3.4 193 4 198 305 10.6 0 10.8 10.5 08/03/2005 22:00:00 5.7 0.6 6.8 3.8 5.6 0.6 6.8 3.8 197 5 197 305 10.8 0 11 10.5 08/03/2005 22:10:00 6.1 0.4 6.8 4.9 6.1 0.4 6.8 4.9 204 3 207 305 10.7 0 11 10.5 08/03/2005 22:20:00 5.7 0.4 6.5 4.2 5.6 0.5 6.8 4.2 205 4 197 305 10.7 0 11 10.5 08/03/2005 22:30:00 5.7 0.4 6.8 4.6 5.5 0.5 6.5 3.8 205 6 208 305 10.8 0 11.3 10.5 08/03/2005 22:40:00 5.7 0.4 6.5 4.6 5.6 0.5 6.5 4.2 203 3 203 305 10.9 0 11.3 10.8 08/03/2005 22:50:00 5.6 0.4 6.8 4.6 5.5 0.5 6.8 4.2 200 6 210 305 10.9 0 11.3 10.8 08/03/2005 23:00:00 5.1 0.5 6.5 3.4 5.2 0.5 6.5 3.8 189 5 186 305 11 0 11.3 10.8 08/03/2005 23:10:00 4.9 0.5 5.7 3 5.1 0.5 6.1 3.8 187 5 193 305 11 0 11.3 10.8 08/03/2005 23:20:00 4.9 0.4 5.7 3 4.9 0.4 5.7 3.8 187 3 184 305 11 0 11.3 10.8 08/03/2005 23:30:00 5 0.4 6.5 3.8 5.1 0.4 6.5 3.8 187 3 194 305 11.1 0 11.3 11 08/03/2005 23:40:00 5.4 0.5 6.1 3.4 5.7 0.4 6.5 4.6 185 3 185 305 11.1 0 11.3 11 08/03/2005 23:50:00 6 0.5 7.6 4.2 6 0.5 7.6 4.2 188 4 192 305 11.2 0 11.6 11 08/04/2005 00:00:00 6.3 0.8 7.6 4.2 6.3 0.8 8 3.8 194 6 198 305 11 0 11.3 10.8 08/04/2005 00:10:00 6.4 0.5 7.6 4.9 6.2 0.5 7.6 4.6 197 5 196 305 10.8 0 11.3 10.8 08/04/2005 00:20:00 6.3 0.5 7.6 4.2 6.2 0.6 7.2 4.2 197 4 201 305 10.8 0 11.3 10.8 08/04/2005 00:30:00 6.5 0.4 8 5.7 6.4 0.5 7.6 4.6 200 4 202 305 10.8 0 11.3 10.8 08/04/2005 00:40:00 6.7 0.5 8 4.6 6.6 0.6 8 4.6 201 4 192 305 10.8 0 11.3 10.5 08/04/2005 00:50:00 6.2 0.6 8 4.2 6 0.7 7.6 4.2 198 5 201 305 10.7 0 11 10.5 08/04/2005 01:00:00 6.5 0.5 7.6 4.9 6.3 0.5 7.6 4.6 201 4 196 305 10.8 0 11.3 10.8 08/04/2005 01:10:00 6.4 0.5 7.2 5.3 6.2 0.5 7.2 4.6 199 4 198 305 10.8 0 11.3 10.5 08/04/2005 01:20:00 5.7 0.5 6.8 4.2 5.6 0.5 6.8 4.2 202 4 210 305 10.8 0 11.3 10.8 08/04/2005 01:30:00 5.7 0.4 6.5 4.6 5.5 0.5 6.5 4.2 201 4 212 305 10.8 0 10.8 10.8 08/04/2005 01:40:00 5.2 0.5 6.5 3.8 5 0.6 6.1 3.4 201 4 200 305 10.8 0 11.3 10.8 08/04/2005 01:50:00 5.3 0.5 6.5 3.8 5.1 0.5 6.1 3.8 197 5 203 305 10.8 0 11.3 10.8 08/04/2005 02:00:00 5.3 0.7 6.8 3.4 5.1 0.8 6.8 3.4 193 6 190 305 10.8 0 11.3 10.8 08/04/2005 02:10:00 5.4 0.6 6.8 3.4 5.3 0.6 6.8 3.8 192 5 197 305 10.8 0 11.3 10.8 08/04/2005 02:20:00 5.4 0.4 6.5 3.8 5.6 0.4 6.5 4.2 188 4 196 305 10.8 0 11.3 10.5 08/04/2005 02:30:00 5.3 0.6 6.5 3.8 5.5 0.5 6.8 4.6 186 4 191 305 10.8 0 11.3 10.5 08/04/2005 02:40:00 5.3 0.8 7.2 3 5.9 0.6 7.2 4.2 183 5 183 305 10.8 0 11.3 10.8 08/04/2005 02:50:00 6 0.9 7.6 3.8 6.8 0.6 8 4.9 182 4 184 305 11 0.1 11.3 10.8 08/04/2005 03:00:00 6.6 0.7 8 4.2 7.2 0.5 8.4 5.7 183 4 186 305 10.9 0 11.3 10.8 08/04/2005 03:10:00 6.8 0.9 8.8 4.2 7.4 0.6 9.1 5.7 183 4 192 305 10.9 0 11.3 10.8 08/04/2005 03:20:00 5.6 1.2 8.8 2.6 6.6 0.9 9.1 4.2 180 6 185 305 11 0 11.3 10.8 08/04/2005 03:30:00 6.2 1 8.4 3.4 7.1 0.6 8.4 5.3 183 5 187 305 10.9 0 11.3 10.8 08/04/2005 03:40:00 7.2 0.8 9.1 4.9 7.9 0.8 9.5 6.1 184 5 186 305 10.8 0 11.3 10.8 08/04/2005 03:50:00 7.5 0.8 9.1 5.3 8 0.7 9.9 5.7 185 4 190 305 11 0 11.3 10.8 08/04/2005 04:00:00 6.7 0.6 8 4.6 7 0.6 8.4 5.3 187 4 185 305 10.9 0 11.3 10.8 08/04/2005 04:10:00 7 0.7 8.4 4.9 6.7 0.9 8.4 4.6 196 4 192 305 11 0.1 11.3 10.8 08/04/2005 04:20:00 7.6 0.5 8.8 5.7 7.5 0.5 8.4 5.7 198 4 196 305 11 0 11.6 11 08/04/2005 04:30:00 7.2 0.5 8.8 5.7 7 0.6 8.4 5.3 200 4 194 305 11 0 11.6 10.8 08/04/2005 04:40:00 6.9 1 8.8 3.8 7.2 0.8 8.8 5.3 188 6 198 305 10.8 0 11.3 10.8 08/04/2005 04:50:00 7.1 0.8 8.8 4.6 7.6 0.7 9.1 5.3 185 4 186 305 10.9 0.1 11.3 10.8 08/04/2005 05:00:00 6.8 0.8 8.4 4.6 7.1 0.7 9.1 4.9 186 4 186 305 11 0 11.3 10.8 08/04/2005 05:10:00 6.4 0.6 7.6 4.2 6.6 0.7 8 4.6 186 3 183 305 10.9 0 11.3 10.8 08/04/2005 05:20:00 6.4 0.5 7.6 4.6 6.6 0.5 8 5.3 187 3 189 305 11 0 11.6 11 08/04/2005 05:30:00 5.2 0.6 6.5 3.8 5.5 0.5 6.5 4.2 187 4 192 305 11 0 11 10.8 08/04/2005 05:40:00 4.1 0.6 5.7 2.6 4.7 0.7 6.1 3 184 6 183 305 10.9 0 11.3 10.8 08/04/2005 05:50:00 5.3 0.7 6.8 2.6 5.8 0.5 6.8 4.2 184 4 188 305 11 0 11.3 11 08/04/2005 06:00:00 5.5 1.1 8 2.6 6.3 0.8 8 4.2 182 6 187 305 11 0 11.6 11 08/04/2005 06:10:00 6.3 0.9 8.4 4.2 7.2 0.6 8.8 5.7 182 4 188 305 11 0 11.6 11 08/04/2005 06:20:00 6.7 0.7 8.4 4.6 6.9 0.7 8.4 4.9 187 4 188 305 11 0 11.6 11 08/04/2005 06:30:00 6.7 0.6 8 4.6 6.9 0.6 8.4 5.7 187 4 186 305 11 0 11.3 11 08/04/2005 06:40:00 6 0.8 7.6 3.4 6.5 0.6 7.6 5.3 185 5 187 305 11 0 11.6 10.8 08/04/2005 06:50:00 5.6 1.1 8 3 6.6 0.9 8.4 4.2 180 5 185 305 11 0 11.3 11 08/04/2005 07:00:00 5.5 1 8 3 7 0.7 9.5 5.3 176 7 184 305 11.1 0 11.3 11 08/04/2005 07:10:00 4.5 0.9 7.2 2.6 6.1 0.8 8.4 3.8 168 5 163 305 11 0 11.6 11 08/04/2005 07:20:00 5 0.7 7.2 3.4 7.8 0.8 9.5 4.6 172 4 174 305 11.2 0 11.6 11 08/04/2005 07:30:00 5.9 1.2 9.5 3.4 7.7 1 10.3 4.9 177 7 185 305 11.3 0 11.3 11.3 08/04/2005 07:40:00 7.8 1.5 11.5 4.2 9 1.1 11.8 6.1 182 7 190 305 11.1 0 11.3 10.8 08/04/2005 07:50:00 10 0.8 11.8 7.6 9.6 0.9 11.5 6.8 196 5 195 305 10.8 0 11.3 10.8 08/04/2005 08:00:00 7.6 1.3 10.3 4.6 7.9 1 10.3 5.3 188 6 197 305 10.8 0 11.3 10.8 08/04/2005 08:10:00 7.9 1.3 10.7 4.6 7.8 1.2 10.7 4.2 191 5 188 305 10.7 0 11.3 10.5 08/04/2005 08:20:00 9.2 1.1 11.5 6.5 9.2 1.1 11.8 6.8 191 5 200 305 10.6 0 11 10.5 08/04/2005 08:30:00 7.5 1.1 9.9 4.6 8 1 10.3 5.7 185 5 189 305 10.6 0 11 10.5 08/04/2005 08:40:00 9.9 0.9 11.5 7.2 9.8 0.8 11.5 7.2 201 5 202 305 10.5 0 11 10.2 08/04/2005 08:50:00 9.3 0.8 11.5 6.8 9.1 0.9 11.1 6.8 194 5 194 305 10.5 0.1 11 10.2 08/04/2005 09:00:00 9.2 0.8 11.5 6.8 9 0.9 11.8 6.8 195 6 195 305 10.8 0 11.3 10.5 08/04/2005 09:10:00 9.9 0.8 11.8 8.4 9.8 0.8 11.8 7.6 200 4 203 305 10.7 0.1 11 10.2 08/04/2005 09:20:00 9.9 0.9 11.8 7.2 9.7 1 11.8 6.8 195 5 190 305 10.3 0 10.8 10.2 08/04/2005 09:30:00 8.2 1.1 11.1 4.9 8.8 1 11.5 5.7 186 6 184 305 10.3 0 10.8 10.2 08/04/2005 09:40:00 9.4 1.1 11.5 5.7 9.3 1.1 11.8 6.1 191 5 194 305 10.5 0 10.8 10.2 08/04/2005 09:50:00 8.6 1.2 11.1 4.2 9.1 1 11.1 6.5 187 6 192 305 10.6 0 10.8 10.5 08/04/2005 10:00:00 9.3 1.2 11.5 5.7 9.7 1 11.8 6.8 188 6 192 305 10.8 0 11.3 10.8 08/04/2005 10:10:00 9.3 1 11.5 6.1 9.1 1.1 11.5 6.1 194 6 186 305 10.9 0 11.3 10.8 08/04/2005 10:20:00 9.4 1 11.5 6.8 9.2 1 11.5 6.1 193 5 199 305 10.8 0 11.3 10.8 08/04/2005 10:30:00 9.7 1 11.8 6.1 9.6 1.1 11.8 6.5 192 5 188 305 10.7 0 11.3 10.5 08/04/2005 10:40:00 9.7 0.8 11.5 6.8 9.4 1 11.5 6.5 194 4 190 305 10.4 0.1 10.8 10.2 08/04/2005 10:50:00 8.2 1.3 10.7 4.6 8.9 1 11.1 6.1 184 6 186 305 10.4 0 10.8 10.2 08/04/2005 11:00:00 7.7 1.1 10.3 4.9 8.9 1 11.1 6.1 182 5 184 305 10.3 0 10.5 10.2 08/04/2005 11:10:00 7.2 1.3 10.7 4.2 9 1.1 11.8 6.1 179 7 183 305 10.3 0 10.5 10.2 08/04/2005 11:20:00 8.5 1.2 11.1 4.9 9.6 0.9 11.8 7.2 183 5 190 305 10.4 0 10.5 10.2 08/04/2005 11:30:00 8.5 1.1 11.1 5.7 9.3 0.8 11.8 6.8 184 5 186 305 10.4 0 10.5 10.2 08/04/2005 11:40:00 7.7 1.1 10.3 4.9 9.2 1 11.5 6.8 181 5 193 305 10.4 0.1 11 10.2 08/04/2005 11:50:00 8.8 1.4 12.6 4.6 10 1.2 13 7.2 183 5 187 305 10.6 0.1 11 10.5 08/04/2005 12:00:00 8 1.2 11.1 5.3 9.2 0.9 11.5 6.8 182 5 184 305 10.6 0 11 10.5 08/04/2005 12:10:00 9.4 1.1 12.2 6.1 10.2 1 12.6 7.2 184 5 187 305 10.6 0 11 10.5 08/04/2005 12:20:00 8.4 1.2 11.1 4.9 9.5 0.8 11.8 6.8 183 5 189 305 10.6 0 11 10.5 08/04/2005 12:30:00 8.2 1.1 10.7 5.7 8.5 0.9 10.7 5.3 187 5 188 305 10.8 0 11 10.5 08/04/2005 12:40:00 10.1 1.2 12.6 5.7 10 1.3 12.6 6.1 190 5 190 305 10.8 0 11.3 10.8 08/04/2005 12:50:00 10.1 1 12.6 6.8 9.7 1.1 12.2 6.5 192 5 187 305 10.9 0 11.3 10.8 08/04/2005 13:00:00 10.1 0.7 11.8 7.6 9.9 0.9 11.5 6.8 196 4 194 305 10.8 0 11.3 10.8 08/04/2005 13:10:00 9.8 0.9 12.2 7.6 9.7 1.1 12.2 6.8 192 5 191 305 10.9 0 11.3 10.8 08/04/2005 13:20:00 11 0.9 13 7.6 10.7 1 12.6 8 192 5 193 305 11 0.1 11.3 10.8 08/04/2005 13:30:00 11.5 1.1 14.1 8 11.3 1.3 14.1 7.2 190 5 186 305 11 0.1 11.3 10.8 08/04/2005 13:40:00 11.2 1 14.1 8 11.1 1.3 14.1 7.2 190 5 192 305 11 0 11.3 10.8 08/04/2005 13:50:00 11.6 1.2 14.1 7.6 11.7 1.2 14.9 8.4 188 5 193 305 11 0.1 11.3 10.8 08/04/2005 14:00:00 11.6 0.9 13.7 8.8 11.3 1 13.7 8.4 191 5 196 305 10.9 0 11.3 10.8 08/04/2005 14:10:00 12 1.1 14.5 8.4 11.6 1.2 14.1 8.4 192 4 189 305 10.9 0 11.3 10.8 08/04/2005 14:20:00 11.4 0.9 13.3 8.8 11.1 1 13.7 8 193 4 196 305 10.9 0 11.3 10.8 08/04/2005 14:30:00 11.2 1 13.7 8.8 10.9 1.2 13.3 8 193 5 188 305 11 0 11.6 10.8 08/04/2005 14:40:00 11.5 1.1 14.1 7.6 11.1 1.2 13.7 7.6 193 5 186 305 11 0.1 11.6 10.8 08/04/2005 14:50:00 11.6 0.9 14.1 8.8 11.1 1.1 13.3 7.2 194 5 196 305 10.8 0 11.3 10.8 08/04/2005 15:00:00 11.6 0.9 14.1 8.4 11.2 1.1 14.1 7.2 192 4 192 305 10.9 0 11.6 10.8 08/04/2005 15:10:00 11.9 0.9 14.5 9.1 11.6 1 14.1 8.4 192 4 190 305 10.8 0 11.3 10.8 08/04/2005 15:20:00 12.2 1 14.5 8.8 11.9 1.2 14.5 8 192 5 193 305 10.9 0 11.3 10.8 08/04/2005 15:30:00 13.1 1 14.9 9.9 12.6 1.2 14.9 8.8 193 5 192 305 10.8 0 11 10.8 08/04/2005 15:40:00 12.9 1.1 15.6 9.5 12.5 1.3 15.3 8.8 193 5 198 305 10.8 0 11.3 10.8 08/04/2005 15:50:00 12.5 1 15.3 8.8 12 1.1 14.9 8.4 192 5 186 305 10.8 0 11.3 10.8 08/04/2005 16:00:00 12.7 1.3 15.3 8.8 12.2 1.5 15.3 8 194 5 198 305 10.8 0 11.3 10.5 08/04/2005 16:10:00 12.3 1 14.9 9.5 11.9 1.2 14.9 8.4 194 4 194 305 10.7 0 11 10.5 08/04/2005 16:20:00 12.6 0.8 14.5 9.9 12.2 0.9 14.1 9.5 194 4 196 305 10.6 0.1 11 10.5 08/04/2005 16:30:00 12.6 1 15.3 9.1 12.1 1.2 15.3 7.6 195 4 196 305 10.6 0 11 10.5 08/04/2005 16:40:00 13.2 1.1 15.6 9.9 12.8 1.2 15.3 8.8 195 4 200 305 10.6 0 11 10.5 08/04/2005 16:50:00 13.2 0.8 15.3 10.3 12.6 1.1 15.3 9.1 196 4 198 305 10.5 0.1 10.8 10.2 08/04/2005 17:00:00 13.5 1 15.6 10.7 13.1 1.2 15.6 9.5 197 4 198 305 10.4 0.1 10.8 10.2 08/04/2005 17:10:00 13.8 0.8 15.3 11.5 13.3 1 15.3 10.3 197 4 198 305 10.4 0.1 10.8 10.2 08/04/2005 17:20:00 13.5 0.9 15.6 10.7 12.9 1 14.9 9.9 197 4 200 305 10.4 0.1 11 10.2 08/04/2005 17:30:00 13.6 1.2 16.8 9.5 13 1.4 16.8 9.1 200 4 206 305 10.3 0 10.8 10.2 08/04/2005 17:40:00 12.9 0.8 14.9 10.7 12.3 0.9 14.1 9.1 197 4 199 305 10.3 0 10.8 10.2 08/04/2005 17:50:00 13.1 0.9 14.9 9.5 12.6 1.1 14.5 8.4 198 4 197 305 10.3 0 10.8 10.2 08/04/2005 18:00:00 12.9 0.9 15.6 10.3 12.4 1.1 15.3 9.5 199 3 205 305 10.3 0 10.8 10.2 08/04/2005 18:10:00 12.9 0.9 14.9 10.7 12.4 1 14.5 9.5 201 4 204 305 10.3 0 10.8 10.2 08/04/2005 18:20:00 13.6 0.9 15.6 11.1 13.2 1 15.3 10.3 201 4 206 305 10.3 0 10.8 10.2 08/04/2005 18:30:00 13.6 0.9 16.1 10.7 13.1 1 15.6 10.3 201 4 203 305 10.3 0 10.8 10.2 08/04/2005 18:40:00 12.9 1 15.3 9.9 12.5 1.1 14.9 8.8 201 3 200 305 10.3 0 10.8 10.2 08/04/2005 18:50:00 12.7 0.9 15.3 10.7 12.1 1 14.9 9.1 203 4 203 305 10.3 0 10.8 10.2 08/04/2005 19:00:00 12.4 0.9 14.9 9.9 12 1 14.5 9.1 202 4 205 305 10.3 0 10.5 10.2 08/04/2005 19:10:00 12.6 0.9 14.5 9.5 12.1 1 14.1 9.1 201 4 205 305 10.3 0 10.8 10.2 08/04/2005 19:20:00 13.2 0.9 15.6 10.7 12.7 1 15.3 9.9 201 4 203 305 10.3 0 10.5 10.2 08/04/2005 19:30:00 12.9 0.9 15.3 9.9 12.5 1 14.5 9.1 201 4 204 305 10.3 0 10.8 10.2 08/04/2005 19:40:00 12.4 0.9 14.5 10.3 12.1 1 14.5 9.5 201 4 198 305 10.3 0 10.5 10.2 08/04/2005 19:50:00 12 0.8 14.1 9.9 11.6 0.8 13.7 9.5 200 4 203 305 10.3 0 10.8 10.2 08/04/2005 20:00:00 12.2 0.8 13.7 9.5 11.7 0.9 13.3 8.8 200 4 197 305 10.3 0 10.8 10.2 08/04/2005 20:10:00 11.8 0.8 13.7 9.1 11.3 0.8 13.3 8 202 4 204 305 10.3 0 10.8 10.2 08/04/2005 20:20:00 11.9 0.7 13.3 10.3 11.4 0.8 13.3 8.4 201 4 205 305 10.3 0 10.8 10.2 08/04/2005 20:30:00 12 0.8 14.1 9.5 11.7 0.9 13.7 8.8 203 4 203 305 10.3 0 10.8 10.2 08/04/2005 20:40:00 11.8 0.7 14.1 9.5 11.4 0.8 13.3 9.1 204 3 206 305 10.3 0 10.8 10.2 08/04/2005 20:50:00 11.3 0.7 13 9.1 10.7 0.8 12.6 8.4 205 4 203 305 10.3 0 10.8 10.2 08/04/2005 21:00:00 11.2 0.7 13.3 8.8 10.7 0.8 12.2 8 205 4 215 305 10.3 0 10.8 10.2 08/04/2005 21:10:00 11.1 1.1 13 7.6 10.2 1.3 12.6 6.8 210 5 209 305 10.3 0 10.8 10.2 08/04/2005 21:20:00 10.5 1.1 13 7.6 9.6 1.2 12.6 6.8 210 7 211 305 10.3 0 10.8 10.2 08/04/2005 21:30:00 10.6 1.1 13.3 6.5 9.5 1.1 12.2 6.8 210 6 218 305 10.3 0 10.8 10.2 08/04/2005 21:40:00 10.5 1.1 12.6 7.2 9.5 1.1 12.2 6.5 210 6 209 305 10.3 0 10.8 10.2 08/04/2005 21:50:00 10.5 1 12.6 7.2 9.4 1.1 12.2 6.5 211 6 217 305 10.3 0 10.8 10.2 08/04/2005 22:00:00 10.8 1 13 8 9.9 1 12.2 6.8 210 6 212 305 10.3 0 10.8 10.2 08/04/2005 22:10:00 10.8 1.1 13.3 7.6 9.5 1.2 13 6.5 211 6 218 305 10.3 0 10.8 10.2 08/04/2005 22:20:00 10.7 1 12.6 6.5 9.6 1.2 12.2 6.1 211 5 217 305 10.3 0 10.8 10.2 08/04/2005 22:30:00 10.4 1 12.6 7.6 9.3 1.2 11.5 5.7 212 6 215 305 10.3 0 10.8 10.2 08/04/2005 22:40:00 10.8 0.9 12.6 8 9.9 1.1 12.6 6.8 213 5 206 305 10.3 0 10.8 10.2 08/04/2005 22:50:00 10.9 0.7 12.6 9.1 10 1 11.8 7.2 213 4 207 305 10.3 0 10.8 10.2 08/04/2005 23:00:00 10.3 0.9 11.8 7.6 9.3 1 11.8 6.1 211 6 214 305 10.3 0 10.8 10.2 08/04/2005 23:10:00 10.5 0.8 12.6 7.6 9.4 1 11.5 6.5 212 5 201 305 10.3 0 10.2 10.2 08/04/2005 23:20:00 10.8 0.8 13 8 9.9 1 12.2 7.2 214 4 211 305 10.3 0 10.2 10.2 08/04/2005 23:30:00 10.9 0.7 12.6 8.4 10 0.9 12.2 7.6 214 4 218 305 10.2 0 10.2 10.2 08/04/2005 23:40:00 10.9 0.7 13 8.8 10 0.9 12.6 6.5 214 4 215 305 10.2 0 10.2 10.2 08/04/2005 23:50:00 10.8 0.8 12.6 8 10 0.9 11.8 7.2 214 4 218 305 10.2 0 10.2 10.2 08/05/2005 00:00:00 11.2 0.9 13.3 8 10.4 1 12.6 7.6 214 4 211 305 10.2 0 10.8 10 08/05/2005 00:10:00 10.9 0.8 12.6 8 10 1 12.2 6.8 214 5 213 305 10.2 0 10.2 10.2 08/05/2005 00:20:00 10.7 0.7 12.2 8 10.1 0.9 11.8 6.8 214 4 217 305 10.2 0 10.2 10.2 08/05/2005 00:30:00 10.4 0.6 12.2 7.6 9.6 0.9 11.5 7.2 213 4 213 305 10.2 0 10.2 10 08/05/2005 00:40:00 10.1 0.7 11.8 7.6 9.2 1 11.5 6.5 213 5 221 305 10.2 0 10.2 10 08/05/2005 00:50:00 10 0.8 11.8 7.2 9.2 1 11.1 6.8 213 5 214 305 10.2 0 10.2 10 08/05/2005 01:00:00 9.8 0.8 11.8 7.2 8.8 1 11.1 6.1 212 6 209 305 10.2 0 10.2 10.2 08/05/2005 01:10:00 9.4 1 11.8 6.1 8.4 1 11.1 5.3 210 6 210 305 10.2 0 10.2 10.2 08/05/2005 01:20:00 9.1 0.9 11.1 6.5 8.4 0.9 10.7 5.7 210 6 206 305 10.2 0 10.8 10.2 08/05/2005 01:30:00 9.4 0.8 11.1 6.8 8.7 1 11.1 6.1 210 5 209 305 10.2 0 10.5 10.2 08/05/2005 01:40:00 9.5 0.9 11.8 6.5 8.5 1 10.7 6.1 210 6 210 305 10.2 0 10.5 10 08/05/2005 01:50:00 9.6 1 11.5 6.1 8.5 1 11.5 6.1 210 6 205 305 10.1 0 10.5 10 08/05/2005 02:00:00 9.5 1 11.5 6.8 8.7 1 11.1 5.7 210 6 209 305 10.1 0 10.5 10 08/05/2005 02:10:00 10.2 1 12.2 7.2 9.3 1.1 11.8 6.5 209 6 212 305 10.1 0 10.2 10 08/05/2005 02:20:00 9.6 1 12.2 6.5 8.7 1.1 11.5 5.7 210 6 208 305 10.1 0 10.5 10 08/05/2005 02:30:00 9.4 1 11.5 6.1 8.3 1 10.7 5.7 210 6 211 305 10.1 0 10.2 10 08/05/2005 02:40:00 9.4 1 11.8 6.5 8.4 1 11.1 5.3 211 6 210 305 10.1 0 10.5 10 08/05/2005 02:50:00 10 0.8 11.5 7.2 9 1 11.5 6.1 211 6 224 305 10 0 10.5 10 08/05/2005 03:00:00 10.4 0.8 12.2 7.6 9.4 1 11.8 6.5 212 5 213 305 10 0 10.2 10 08/05/2005 03:10:00 9.7 0.7 11.5 8 8.9 0.9 11.1 6.1 214 4 214 305 10 0 10.2 10 08/05/2005 03:20:00 9.4 1 11.5 6.8 8.4 1 11.1 5.7 211 6 211 305 10 0 10.5 10 08/05/2005 03:30:00 8.8 1.2 11.5 5.7 7.9 1.3 11.5 5.3 211 6 218 305 10 0 10.5 10 08/05/2005 03:40:00 9.5 0.8 11.1 6.8 8.5 1 10.7 5.7 211 6 211 305 10 0 10.2 10 08/05/2005 03:50:00 9.8 1.1 12.2 6.5 8.9 1.2 11.8 6.1 212 6 204 305 9.9 0 10 10 08/05/2005 04:00:00 9.5 0.8 11.5 6.5 8.6 1 10.7 6.1 212 6 214 305 9.9 0 10 10 08/05/2005 04:10:00 9.1 1 11.1 5.7 8.1 1.1 10.7 5.3 212 6 206 305 9.9 0 10 9.7 08/05/2005 04:20:00 9 0.8 10.7 6.1 8.2 0.9 10.3 6.1 211 5 208 305 9.9 0 10.2 9.7 08/05/2005 04:30:00 8.7 1 11.1 6.1 7.8 1 10.3 5.7 210 7 208 305 9.9 0 10.5 9.7 08/05/2005 04:40:00 9.1 1 11.8 6.1 8.3 1 10.7 5.7 209 6 211 305 9.9 0 10.5 10 08/05/2005 04:50:00 9.1 0.9 11.1 6.5 8.2 1.1 10.3 5.7 212 6 212 305 9.9 0 10.5 10 08/05/2005 05:00:00 8.4 0.8 10.7 6.1 7.6 0.9 10.3 5.3 211 6 207 305 10 0 10.5 10 08/05/2005 05:10:00 8.6 0.8 10.3 5.7 8.1 1 9.9 5.3 209 5 213 305 10 0 10.2 10 08/05/2005 05:20:00 8.9 0.8 10.7 6.5 8.1 1 9.9 4.9 212 5 219 305 10 0 10.5 10 08/05/2005 05:30:00 7.9 1 9.9 5.7 7.2 1 9.5 4.6 210 6 208 305 10 0 10.2 10 08/05/2005 05:40:00 8.4 0.8 10.3 6.1 7.7 1 10.3 4.9 210 6 206 305 10 0 10.2 10 08/05/2005 05:50:00 8.3 1 10.3 5.7 7.5 1 9.9 4.9 210 6 213 305 10 0 10.2 10 08/05/2005 06:00:00 8.2 0.8 10.3 5.7 7.7 1 9.9 5.7 208 5 208 305 10 0 10.5 10 08/05/2005 06:10:00 8.8 0.7 10.7 6.8 8.5 0.7 10.3 6.5 207 4 214 305 10 0 10.5 10 08/05/2005 06:20:00 8.5 0.5 9.9 6.8 8.2 0.6 9.5 6.5 206 4 206 305 10 0 10.5 10 08/05/2005 06:30:00 8.8 0.6 9.9 7.6 8.6 0.6 10.3 6.8 205 3 202 305 10 0 10.5 10 08/05/2005 06:40:00 9 0.5 10.3 7.2 8.6 0.6 10.3 6.5 203 3 208 305 10 0 10.2 10 08/05/2005 06:50:00 8.7 0.6 10.3 6.8 8.4 0.7 9.9 6.5 202 3 203 305 10 0 10.2 10 08/05/2005 07:00:00 8.2 0.6 9.5 6.1 8 0.7 9.9 5.3 197 4 200 305 10.1 0 10.2 10 08/05/2005 07:10:00 9.4 0.7 11.5 7.6 9.2 0.8 11.1 6.8 196 4 197 305 10 0 10.2 10 08/05/2005 07:20:00 9.6 0.6 11.1 8 9.4 0.8 11.1 6.8 196 4 196 305 10 0 10.2 10 08/05/2005 07:30:00 8.8 0.8 10.7 5.3 8.6 0.9 10.3 5.7 194 5 198 305 10 0 10.5 10 08/05/2005 07:40:00 9.1 0.6 10.7 6.8 8.9 0.8 10.3 6.5 193 4 190 305 10 0 10.5 10 08/05/2005 07:50:00 9.6 0.7 11.1 7.2 9.4 0.7 11.1 7.2 195 4 202 305 10.1 0 10.2 10 08/05/2005 08:00:00 10.2 0.7 12.2 8.4 10 0.8 12.2 8 199 4 207 305 10.1 0 10.5 10 08/05/2005 08:10:00 10.1 0.7 11.8 8 9.8 0.9 11.5 6.8 197 5 196 305 10.2 0 10.5 10 08/05/2005 08:20:00 9.8 0.8 11.5 6.5 9.5 0.9 11.1 6.5 195 4 196 305 10.2 0 10.2 10 08/05/2005 08:30:00 9.7 0.8 11.5 7.2 9.3 1 11.5 6.8 193 4 198 305 10.3 0 10.8 10.2 08/05/2005 08:40:00 9.9 0.7 11.8 8.4 9.6 0.8 11.8 6.8 196 4 198 305 10.3 0 10.5 10.2 08/05/2005 08:50:00 9.8 0.7 11.5 7.2 9.6 0.7 11.5 7.2 195 4 192 305 10.3 0 10.5 10.2 08/05/2005 09:00:00 9.4 0.6 10.7 7.2 9.1 0.8 10.7 6.5 197 4 201 305 10.3 0 10.8 10.2 08/05/2005 09:10:00 10 0.5 11.5 8 9.8 0.6 11.5 7.2 199 3 203 305 10.3 0 10.8 10.2 08/05/2005 09:20:00 8.8 0.6 10.3 7.2 8.6 0.7 10.3 6.5 197 4 198 305 10.3 0 10.8 10.2 08/05/2005 09:30:00 8.6 0.6 9.9 6.1 8.4 0.8 10.3 6.5 191 5 189 305 10.4 0.1 10.8 10.2 08/05/2005 09:40:00 8.5 0.7 10.3 6.8 8.2 0.8 9.9 6.1 197 4 194 305 10.5 0 10.8 10.2 08/05/2005 09:50:00 8.6 0.8 10.3 6.5 8.2 1 10.3 5.3 196 5 195 305 10.4 0 10.8 10.2 08/05/2005 10:00:00 8.3 0.6 9.5 6.5 8.1 0.7 9.5 5.3 197 5 203 305 10.3 0 10.5 10.2 08/05/2005 10:10:00 8.7 0.7 9.9 5.3 8.4 0.8 9.9 5.3 201 7 210 305 10.4 0 10.8 10.2 08/05/2005 10:20:00 8.9 0.9 10.3 6.5 8.6 1 10.3 6.1 202 4 208 305 10.2 0 10.5 10.2 08/05/2005 10:30:00 9.1 0.5 10.7 7.6 8.8 0.6 10.3 6.8 203 3 207 305 10.2 0 10.8 10.2 08/05/2005 10:40:00 9.7 0.7 11.5 8 9.5 0.7 11.5 7.2 199 4 203 305 10.3 0 10.8 10.2 08/05/2005 10:50:00 8.9 0.8 10.3 6.5 8.6 0.9 10.3 5.7 201 4 201 305 10.4 0 10.8 10.2 08/05/2005 11:00:00 8.4 0.6 9.5 6.5 8.1 0.7 9.5 6.1 201 4 200 305 10.3 0 10.8 10.2 08/05/2005 11:10:00 9.4 0.7 11.1 7.2 8.9 0.9 10.7 6.1 206 5 203 305 10.3 0 10.8 10.2 08/05/2005 11:20:00 10.1 0.9 11.8 7.2 9.1 1 11.5 6.5 209 5 208 305 10.3 0 10.8 10.2 08/05/2005 11:30:00 10.8 1.3 13 7.2 10.1 1.5 12.6 6.5 207 5 206 305 10.6 0 11 10.2 08/05/2005 11:40:00 10.7 0.7 12.6 8 10.3 0.8 12.2 7.6 203 4 205 305 10.5 0 10.8 10.2 08/05/2005 11:50:00 10.4 0.7 12.2 8.4 10.1 0.8 11.8 7.6 198 4 199 305 10.5 0 10.8 10.2 08/05/2005 12:00:00 9.9 0.7 11.8 8 9.6 0.8 11.5 7.2 195 5 198 305 10.6 0 11 10.5 08/05/2005 12:10:00 7.8 1.8 10.7 3.4 8.4 1.2 10.7 5.7 186 8 192 305 10.6 0 11 10.5 08/05/2005 12:20:00 5.9 1.7 9.5 3 6.9 1.3 9.9 4.6 178 8 188 305 10.8 0.1 11.3 10.5 08/05/2005 12:30:00 9.5 1.1 12.2 5.7 10 1 13 6.5 186 6 184 305 11.1 0 11.6 11 08/05/2005 12:40:00 6.4 1.3 9.9 3.8 8.2 0.8 9.9 5.3 176 8 188 305 11.2 0 11.6 11 08/05/2005 12:50:00 6.5 1.3 9.9 3.8 8.4 1 11.8 5.7 165 8 162 305 11.2 0 11.3 11 08/05/2005 13:00:00 7.2 1.5 11.5 4.2 8.9 1.1 12.2 5.7 164 9 155 305 11.1 0 11.3 11 08/05/2005 13:10:00 6.7 1.1 9.9 4.6 9.4 0.8 11.8 7.2 174 6 166 305 11 0 11.3 11 08/05/2005 13:20:00 7 1.2 9.5 4.2 8.3 0.8 9.9 6.1 180 6 189 305 11.1 0 11.3 11 08/05/2005 13:30:00 6.9 1.3 10.3 3.8 9 1 11.5 6.1 175 7 188 305 11.1 0 11.3 11 08/05/2005 13:40:00 6.7 1.3 11.1 4.2 8.9 1.1 11.5 6.1 172 7 185 305 11.1 0 11.3 11 08/05/2005 13:50:00 7 1.2 10.3 4.2 9.2 1 11.8 6.5 173 8 156 305 11.2 0 11.3 11 08/05/2005 14:00:00 7 1.3 11.1 4.6 9.7 1 12.2 7.2 174 6 174 305 11.3 0 11.3 11.3 08/05/2005 14:10:00 7.1 1.4 11.5 4.6 8.9 1 11.8 6.5 170 9 146 305 11.2 0 11.3 11 08/05/2005 14:20:00 6.9 1.3 11.1 4.2 8.8 1.1 11.8 5.7 165 9 154 305 11.1 0 11.3 11 08/05/2005 14:30:00 6.5 1.5 11.1 3.4 7 1.2 10.3 3.8 160 15 163 305 11 0 11.3 11 08/05/2005 14:40:00 7.8 1.4 13.3 4.6 10.4 1.3 14.1 6.8 173 7 154 305 11.2 0 11.3 11 08/05/2005 14:50:00 7.4 1.4 11.5 4.2 9.8 1.4 13.3 6.8 172 8 185 305 11.2 0 11.3 11 08/05/2005 15:00:00 8.1 1.3 11.8 4.9 10.8 1.4 14.5 7.6 171 8 186 305 11.4 0 11.3 11.3 08/05/2005 15:10:00 9.2 1.6 14.1 5.3 11.3 1.4 16.4 7.6 178 6 183 305 11.4 0 11.6 11.3 08/05/2005 15:20:00 9.5 1.7 14.1 4.9 11.6 1.4 15.3 8 178 6 192 305 11.4 0 11.6 11.3 08/05/2005 15:30:00 9.5 1.9 14.1 5.3 12 1.7 15.3 8 177 6 183 305 11.4 0 11.3 11.3 08/05/2005 15:40:00 10.5 1.5 15.3 6.1 12.4 1.2 15.6 9.1 181 5 184 305 11.4 0 11.8 11 08/05/2005 15:50:00 10.1 1.7 14.5 5.3 12 1.5 14.9 8.4 180 5 182 305 11.4 0 11.6 11.3 08/05/2005 16:00:00 9 1.6 13.7 5.7 11.4 1.3 14.9 6.8 177 6 181 305 11.5 0 11.6 11.3 08/05/2005 16:10:00 10.8 1.7 14.5 6.5 12.8 1.5 16.1 8.8 180 5 183 305 11.7 0 11.8 11.6 08/05/2005 16:20:00 11.7 1.7 14.9 6.8 13.3 1.3 16.1 8.4 182 5 181 305 11.7 0 11.8 11.6 08/05/2005 16:30:00 10.5 1.7 14.5 5.3 12.6 1.4 15.6 8.8 179 6 192 305 11.5 0 11.6 11.3 08/05/2005 16:40:00 9.6 2.1 14.5 4.6 11.6 1.7 15.6 6.8 179 6 183 305 11.4 0 11.6 11.3 08/05/2005 16:50:00 9.2 1.9 14.1 4.9 11.6 1.4 15.6 8.4 177 7 188 305 11.2 0 11.3 11 08/05/2005 17:00:00 9.3 1.8 13.3 5.7 11.5 1.5 15.3 7.2 177 7 182 305 11.2 0 11.3 11 08/05/2005 17:10:00 10.7 1.7 15.3 5.7 13 1.5 16.8 9.1 179 5 169 305 11.2 0 11.3 11 08/05/2005 17:20:00 9.2 1.5 14.5 5.3 11.7 1.2 16.1 8.8 177 6 183 305 11.2 0 11.3 11 08/05/2005 17:30:00 10.3 1.7 15.3 5.7 12.8 1.3 16.4 8 178 7 183 305 11.2 0 11.3 11 08/05/2005 17:40:00 11 1.6 15.6 6.5 13.2 1.3 17.2 9.5 180 6 186 305 11.2 0 11.3 11 08/05/2005 17:50:00 11.1 1.5 15.3 7.2 13.1 1.2 16.1 9.9 180 5 189 305 11.2 0 11.3 11 08/05/2005 18:00:00 11.2 1.7 15.6 7.2 13.5 1.5 17.9 10.3 179 5 188 305 11.3 0 11.3 11.3 08/05/2005 18:10:00 11.1 2 15.6 5.7 13.4 1.8 18.3 7.6 179 6 186 305 11.2 0 11.3 11 08/05/2005 18:20:00 11.4 1.9 16.8 7.2 13.2 1.6 17.6 9.1 181 6 183 305 11.2 0 11.3 11 08/05/2005 18:30:00 11.4 1.6 14.9 6.8 13.3 1.2 16.4 9.5 181 6 182 305 11.2 0 11.3 11 08/05/2005 18:40:00 11.2 2.1 16.4 6.5 13.2 1.5 16.4 9.5 181 6 186 305 11.2 0 11.3 11 08/05/2005 18:50:00 11.5 1.9 16.4 6.8 13.7 1.4 17.2 9.9 181 6 196 305 11.2 0 11.3 11 08/05/2005 19:00:00 11.6 1.7 15.6 7.2 13.8 1.3 17.2 9.5 180 6 172 305 11.1 0 11.3 11 08/05/2005 19:10:00 11.8 1.7 15.3 7.6 12.8 1.6 16.8 8.8 183 5 188 305 11.1 0 11.3 11 08/05/2005 19:20:00 12 1.5 15.3 8.4 14.2 1.3 17.9 10.3 181 5 184 305 11 0 11 11 08/05/2005 19:30:00 11.9 1.9 16.4 6.5 13.7 1.6 17.9 9.5 182 5 187 305 10.9 0 11 10.8 08/05/2005 19:40:00 11.6 1.5 15.6 6.8 13.8 1.5 17.6 9.5 181 5 177 305 10.8 0 11 10.8 08/05/2005 19:50:00 11.9 1.7 17.2 7.6 14.2 1.5 17.2 10.3 181 6 194 305 10.8 0 11.3 10.8 08/05/2005 20:00:00 12.1 1.8 16.8 7.2 14 1.5 18.3 9.1 181 5 186 305 10.9 0 11 10.8 08/05/2005 20:10:00 12.4 1.9 17.2 7.6 14.2 1.5 17.6 9.1 181 6 186 305 10.8 0 11.3 10.8 08/05/2005 20:20:00 11.6 1.7 15.6 6.8 13.4 1.5 17.2 9.1 181 5 186 305 10.8 0 11.3 10.5 08/05/2005 20:30:00 11.1 1.5 15.6 7.6 12.4 1.3 15.6 9.5 181 6 190 305 10.6 0 11 10.5 08/05/2005 20:40:00 11.1 1.5 16.1 7.6 13.2 1.5 17.6 9.5 179 6 179 305 10.6 0 11 10.5 08/05/2005 20:50:00 12.9 1.5 17.2 9.5 14.1 1.4 17.2 10.3 183 5 184 305 10.6 0 11 10.5 08/05/2005 21:00:00 12.2 1.4 15.6 8.4 13.5 1.2 16.1 10.3 182 4 184 305 10.5 0.1 11 10.5 08/05/2005 21:10:00 12.4 1.5 16.8 8.8 14.1 1.2 17.2 10.7 181 5 182 305 10.5 0.1 11 10.2 08/05/2005 21:20:00 13.7 1.6 17.2 9.5 15.2 1.5 19.1 10.7 182 5 188 305 10.6 0 11 10.5 08/05/2005 21:30:00 13.3 1.8 17.2 8.8 14.7 1.6 19.1 10.3 182 6 184 305 10.6 0 11 10.5 08/05/2005 21:40:00 12.5 1.8 16.4 6.5 14.3 1.6 17.9 9.9 181 5 181 305 10.6 0 11 10.5 08/05/2005 21:50:00 12.6 1.7 17.2 8 14.8 1.4 18.7 10.7 181 6 184 305 10.6 0 11 10.5 08/05/2005 22:00:00 12.7 1.8 17.9 8 14.5 1.7 18.7 10.3 182 5 186 305 10.6 0 10.8 10.5 08/05/2005 22:10:00 11.9 1.5 16.1 8.8 13.5 1.5 17.2 10.3 182 5 186 305 10.6 0 11 10.5 08/05/2005 22:20:00 14.1 1.8 17.6 8.4 14.8 1.7 18.7 9.5 185 5 188 305 10.6 0 11 10.5 08/05/2005 22:30:00 12.7 1.9 16.4 7.2 14 1.3 16.8 9.9 183 6 189 305 10.6 0 11 10.5 08/05/2005 22:40:00 12.1 1.9 16.4 7.6 13.9 1.6 17.6 9.5 182 6 192 305 10.5 0 10.8 10.5 08/05/2005 22:50:00 13 1.7 17.6 8.8 14.1 1.6 18.3 8.4 183 5 190 305 10.6 0 11 10.5 08/05/2005 23:00:00 12.3 1.9 16.4 7.6 14.5 1.5 17.6 10.3 180 5 184 305 10.6 0 10.8 10.5 08/05/2005 23:10:00 11 1.6 14.9 7.6 13.7 1.3 17.2 9.9 177 7 177 305 10.6 0 10.8 10.5 08/05/2005 23:20:00 10 1.9 15.6 5.7 12.6 1.6 16.8 9.1 175 7 188 305 10.6 0 11 10.5 08/05/2005 23:30:00 9.7 1.7 14.1 6.1 13.1 1.7 17.2 9.1 172 7 161 305 10.6 0 11 10.5 08/05/2005 23:40:00 10.2 1.9 14.5 5.7 12.8 1.7 16.8 8.4 175 8 176 305 10.6 0 10.8 10.5 08/05/2005 23:50:00 10.4 1.9 15.6 6.5 13 1.5 16.4 9.5 176 7 182 305 10.6 0 11 10.5 08/06/2005 00:00:00 10.6 2 16.1 6.5 12.8 1.7 17.9 8.4 177 7 179 305 10.6 0 11 10.5 08/06/2005 00:10:00 10.9 2.2 17.2 6.1 13.6 1.6 17.9 9.5 177 6 181 305 10.6 0 11 10.5 08/06/2005 00:20:00 10.7 2 16.1 6.5 13.2 1.5 16.4 9.9 177 7 194 305 10.6 0 11 10.5 08/06/2005 00:30:00 10 1.7 15.3 6.1 12.6 1.3 15.6 9.1 175 7 182 305 10.5 0 10.8 10.5 08/06/2005 00:40:00 10.2 1.7 15.3 5.7 12.9 1.7 17.2 8 175 7 190 305 10.5 0.1 10.8 10.5 08/06/2005 00:50:00 9.9 1.6 15.3 6.5 12.4 1.4 16.1 9.1 175 8 174 305 10.6 0 11 10.5 08/06/2005 01:00:00 10.5 1.7 16.4 6.5 13 1.4 16.8 9.5 176 6 183 305 10.5 0.1 11 10.2 08/06/2005 01:10:00 10.7 1.7 15.3 6.5 13.2 1.7 16.4 8.4 176 7 185 305 10.4 0.1 10.8 10.2 08/06/2005 01:20:00 10.6 1.7 16.1 6.8 12.8 1.4 16.4 9.1 178 6 188 305 10.3 0 10.8 10.2 08/06/2005 01:30:00 11.5 1.7 16.1 6.8 13.8 1.4 17.9 10.3 177 6 186 305 10.3 0 10.8 10.2 08/06/2005 01:40:00 10.9 1.7 16.8 6.8 13.1 1.5 17.2 9.1 175 8 184 305 10.3 0 10.8 10.2 08/06/2005 01:50:00 11.7 1.8 16.4 6.8 13.9 1.5 17.2 8.8 177 7 183 305 10.3 0 10.8 10.2 08/06/2005 02:00:00 11.6 1.9 16.1 7.2 13.9 1.5 17.6 9.5 178 6 188 305 10.2 0 10.8 10.2 08/06/2005 02:10:00 11.3 1.7 17.2 7.6 13.6 1.5 18.3 9.9 176 8 174 305 10.2 0 10.8 10.2 08/06/2005 02:20:00 11.5 1.7 16.4 6.8 14.7 1.6 19.5 10.7 166 12 182 305 10.3 0 10.8 10.2 08/06/2005 02:30:00 10.8 1.7 15.3 6.8 13.8 1.9 19.5 8.8 154 8 166 305 10.3 0 10.8 10.2 08/06/2005 02:40:00 10.3 1.7 15.6 6.8 12.6 1.5 17.2 8.4 158 7 162 305 10.2 0 10.8 10.2 08/06/2005 02:50:00 10.8 1.7 17.6 7.2 13.2 1.5 16.8 9.1 156 7 162 305 10.3 0 10.8 10.2 08/06/2005 03:00:00 10.9 1.9 16.8 6.8 13.4 1.6 17.6 9.9 159 6 168 305 10.3 0 10.8 10.2 08/06/2005 03:10:00 11 1.7 15.6 6.5 13.2 1.7 17.6 8.8 160 6 162 305 10.3 0 10.8 10.2 08/06/2005 03:20:00 11.3 1.6 15.3 6.8 13.3 1.4 16.4 9.1 161 6 163 305 10.2 0 10.8 10.2 08/06/2005 03:30:00 11.3 1.8 16.1 6.8 13.3 1.6 16.8 7.6 161 6 156 305 10.3 0 10.8 10.2 08/06/2005 03:40:00 10.8 1.7 16.8 7.2 12.9 1.3 16.1 9.5 160 6 172 305 10.3 0 10.8 10.2 08/06/2005 03:50:00 11 1.7 17.2 7.2 13.2 1.5 18.3 8.8 160 7 166 305 10.3 0 10.8 10.2 08/06/2005 04:00:00 11.2 1.6 15.6 6.8 13.2 1.5 17.6 9.1 160 7 167 305 10.3 0 10.8 10.2 08/06/2005 04:10:00 11.3 1.7 15.6 6.5 13.7 1.7 17.9 9.5 160 6 165 305 10.3 0 10.8 10.2 08/06/2005 04:20:00 11.6 1.7 16.1 6.8 13.9 1.5 17.6 9.5 161 5 163 305 10.3 0 10.8 10.2 08/06/2005 04:30:00 11.8 1.5 15.3 8 14.1 1.5 17.9 9.9 162 6 166 305 10.3 0 10.8 10.2 08/06/2005 04:40:00 11.4 1.7 16.4 6.8 13.6 1.4 17.2 8.4 162 5 169 305 10.3 0 10.8 10.2 08/06/2005 04:50:00 11.4 1.6 16.4 7.2 13.8 1.5 17.9 10.3 163 6 169 305 10.4 0.1 11 10.2 08/06/2005 05:00:00 11.7 1.7 17.2 7.6 13.8 1.5 18.3 9.9 162 5 165 305 10.4 0.1 11 10.2 08/06/2005 05:10:00 11.1 1.4 15.3 8 13.2 1.3 16.8 9.5 162 6 167 305 10.3 0.1 10.8 10.2 08/06/2005 05:20:00 11.5 1.5 15.6 7.6 13.2 1.3 16.4 9.5 164 5 168 305 10.3 0 10.8 10.2 08/06/2005 05:30:00 12.3 1.7 16.4 7.6 13.7 1.5 17.9 9.9 165 5 175 305 10.4 0.1 10.8 10.2 08/06/2005 05:40:00 12.5 1.7 16.1 8 13.8 1.3 17.6 10.3 167 6 169 305 10.4 0.1 11 10.2 08/06/2005 05:50:00 13.4 2 17.9 8 14.4 1.5 18.3 9.9 167 5 171 305 10.4 0.1 11 10.2 08/06/2005 06:00:00 12.6 1.7 17.2 8 13.7 1.4 17.6 9.9 167 5 169 305 10.4 0 10.8 10.2 08/06/2005 06:10:00 12.9 1.7 17.2 8.8 14.1 1.5 18.3 10.3 166 5 173 305 10.3 0 10.8 10.2 08/06/2005 06:20:00 12.4 1.7 17.9 8 13.4 1.3 16.4 9.1 167 6 179 305 10.3 0 10.8 10.2 08/06/2005 06:30:00 12.2 1.4 15.6 7.6 13.4 1.3 17.2 9.5 167 6 169 305 10.3 0.1 10.8 10.2 08/06/2005 06:40:00 12.7 1.6 16.4 8.4 13.7 1.2 16.8 9.9 168 5 176 305 10.3 0 10.8 10.2 08/06/2005 06:50:00 12.5 1.7 17.2 7.6 13.1 1.5 17.9 9.5 169 6 165 305 10.4 0.1 10.8 10.2 08/06/2005 07:00:00 12.4 1.5 16.4 8 13.2 1.4 16.8 9.5 169 5 171 305 10.2 0 10.8 10.2 08/06/2005 07:10:00 12.8 1.7 17.9 8 13.5 1.5 17.9 9.5 169 5 172 305 10.3 0 10.8 10.2 08/06/2005 07:20:00 13.7 1.5 17.2 9.5 14 1.5 17.2 10.3 169 5 169 305 10.2 0 10.8 10.2 08/06/2005 07:30:00 13.3 1.6 17.6 9.1 13.4 1.5 17.2 9.5 171 5 178 305 10.2 0 10.8 10.2 08/06/2005 07:40:00 13.3 1.7 17.9 8.4 13.8 1.4 17.9 9.9 170 5 169 305 10.2 0 10.8 10.2 08/06/2005 07:50:00 13.9 1.7 18.3 9.9 14.4 1.5 18.7 11.1 170 5 171 305 10.3 0 10.8 10.2 08/06/2005 08:00:00 13.8 1.8 19.5 10.3 14.1 1.8 19.1 9.5 171 5 171 305 10.3 0 10.5 10.2 08/06/2005 08:10:00 13.7 1.6 17.2 10.3 14.2 1.4 17.6 9.9 171 5 176 305 10.3 0 10.5 10.2 08/06/2005 08:20:00 13.3 1.9 17.2 8 13.8 1.7 17.6 9.1 171 5 172 305 10.3 0 10.5 10.2 08/06/2005 08:30:00 14.8 1.3 17.6 11.5 15.2 1.3 18.3 11.5 171 4 175 305 10.3 0 10.5 10.2 08/06/2005 08:40:00 13.7 1.5 17.2 9.1 14.3 1.6 17.9 9.9 172 5 168 305 10.4 0 10.8 10.2 08/06/2005 08:50:00 14.3 1.3 17.6 11.1 14.8 1.3 18.3 11.1 172 5 175 305 10.5 0 11 10.2 08/06/2005 09:00:00 14.6 1.5 17.6 10.7 15.1 1.4 18.3 9.9 172 5 177 305 10.5 0 11 10.2 08/06/2005 09:10:00 14.6 1.5 18.7 11.1 14.9 1.6 18.7 10.7 173 4 181 305 10.6 0 11 10.5 08/06/2005 09:20:00 14.1 1.3 17.6 10.7 14.1 1.3 17.6 10.7 174 4 177 305 10.6 0 11 10.5 08/06/2005 09:30:00 14.8 1.4 19.1 11.5 14.7 1.4 18.7 9.9 174 5 175 305 10.6 0.1 11 10.5 08/06/2005 09:40:00 14 1.5 17.2 9.5 14.1 1.4 17.2 10.3 174 5 165 305 10.6 0 11.3 10.5 08/06/2005 09:50:00 14.1 1.7 19.9 9.9 14.1 1.7 19.5 9.1 174 5 181 305 10.7 0 11.3 10.5 08/06/2005 10:00:00 15 1.7 18.7 9.1 14.9 1.8 18.7 9.5 175 5 174 305 10.8 0 11.3 10.5 08/06/2005 10:10:00 14.4 1.5 17.9 10.7 14 1.6 17.6 9.1 176 4 179 305 10.8 0 11.3 10.5 08/06/2005 10:20:00 14.5 1.2 17.9 10.3 14.1 1.4 17.6 9.5 176 5 182 305 10.7 0 11.3 10.5 08/06/2005 10:30:00 14.5 1.5 18.7 9.1 13.9 1.7 17.2 8 177 5 174 305 10.7 0 11.3 10.5 08/06/2005 10:40:00 15 1.8 19.9 9.5 14.4 2 19.5 9.1 178 6 183 305 10.8 0 11.3 10.8 08/06/2005 10:50:00 15.2 1.3 19.1 11.8 14.8 1.5 18.7 10.3 178 5 179 305 10.8 0 11.3 10.8 08/06/2005 11:00:00 14.7 2 19.1 9.1 14 2 18.7 9.1 179 6 177 305 11 0.1 11.3 10.8 08/06/2005 11:10:00 16.4 1.4 19.5 12.6 15.7 1.6 19.1 11.5 180 5 185 305 10.8 0 11.3 10.8 08/06/2005 11:20:00 16.1 1.3 18.7 11.5 15.6 1.5 18.7 10.3 181 4 185 305 10.7 0 11 10.5 08/06/2005 11:30:00 16.1 1.3 20.2 12.6 15.3 1.5 19.5 11.1 181 5 184 305 10.8 0 11 10.8 08/06/2005 11:40:00 16.2 1.4 19.1 11.8 15.4 1.6 19.5 11.1 181 5 179 305 10.8 0 11.3 10.8 08/06/2005 11:50:00 15.7 1.5 19.5 11.1 15 1.5 18.3 10.7 180 5 182 305 10.9 0 11 10.8 08/06/2005 12:00:00 15.9 1.1 19.1 12.2 15.4 1.2 19.5 11.5 183 4 183 305 11 0 11 10.8 08/06/2005 12:10:00 15.9 1.1 18.7 12.2 15.3 1.2 18.7 12.2 183 4 179 305 10.8 0 11 10.8 08/06/2005 12:20:00 15.9 1.2 19.1 11.8 15.3 1.4 17.9 11.5 185 4 176 305 10.8 0 10.8 10.5 08/06/2005 12:30:00 15.9 1.6 19.9 12.2 15.2 1.7 19.5 11.5 185 5 182 305 10.8 0 11 10.5 08/06/2005 12:40:00 17 1.3 19.9 13 16.5 1.3 19.5 13 186 4 184 305 11 0 11 10.8 08/06/2005 12:50:00 16.2 1.4 18.7 11.8 15.5 1.5 18.7 9.9 186 5 187 305 10.8 0 11 10.5 08/06/2005 13:00:00 15.9 1.1 18.7 12.6 15.4 1.3 18.3 11.5 186 4 183 305 10.6 0 10.8 10.5 08/06/2005 13:10:00 15.8 1.1 17.9 12.6 15.1 1.2 17.6 11.1 185 4 182 305 10.8 0 11 10.5 08/06/2005 13:20:00 15.7 1 17.6 12.6 15 1.2 17.6 11.1 185 5 179 305 10.9 0 11 10.8 08/06/2005 13:30:00 15.9 1.2 18.7 12.2 15.4 1.3 18.7 11.8 184 4 183 305 11 0 11.3 10.8 08/06/2005 13:40:00 16.1 1.3 18.7 12.2 15.5 1.3 18.3 11.8 184 5 182 305 11 0.1 11.3 10.8 08/06/2005 13:50:00 16.3 1.1 19.1 13 15.9 1.2 18.3 12.2 185 4 186 305 10.9 0.1 11 10.5 08/06/2005 14:00:00 14.7 1 17.9 11.8 14.2 1.1 17.2 11.1 188 4 192 305 10.6 0.2 11 10.2 08/06/2005 14:10:00 14.7 1 17.2 12.2 14.1 1.2 16.8 10.7 188 4 190 305 10.6 0 10.8 10.2 08/06/2005 14:20:00 13.7 1 16.1 11.1 13.2 1.1 16.8 9.9 191 5 185 305 10.4 0.1 10.8 10.2 08/06/2005 14:30:00 14.4 1 17.2 11.1 14 1.1 16.8 11.1 187 4 188 305 10.6 0 10.8 10.2 08/06/2005 14:40:00 13.8 1.1 16.4 11.1 13.4 1.2 16.8 10.3 190 4 191 305 10.4 0 10.5 10.2 08/06/2005 14:50:00 14.4 1.2 17.6 11.1 14 1.2 17.2 10.3 189 4 190 305 10.4 0 10.8 10.2 08/06/2005 15:00:00 13.8 1.2 16.4 10.7 13.3 1.3 16.4 9.9 188 6 189 305 10.7 0 11 10.2 08/06/2005 15:10:00 13.2 0.8 15.6 11.1 12.8 0.9 14.9 10.3 190 4 194 305 10.3 0 10.8 10.2 08/06/2005 15:20:00 13.1 1 15.6 10.7 12.8 1 15.6 9.9 188 4 186 305 10.7 0 10.8 10.5 08/06/2005 15:30:00 13.5 1.1 15.6 10.3 12.9 1.2 15.6 9.5 185 5 179 305 10.8 0 11 10.5 08/06/2005 15:40:00 13.6 1 16.1 10.3 13.2 1.2 15.6 9.5 186 4 187 305 10.8 0 10.8 10.5 08/06/2005 15:50:00 13.4 0.9 15.6 9.9 13 1 15.3 9.9 187 5 184 305 10.6 0 10.8 10.5 08/06/2005 16:00:00 13.7 0.8 15.6 11.5 13.3 0.9 15.3 10.7 189 4 184 305 10.7 0 10.8 10.5 08/06/2005 16:10:00 13.1 1 15.6 10.3 12.7 1 15.3 9.5 189 4 185 305 10.3 0 10.5 10.2 08/06/2005 16:20:00 13.2 1.1 16.1 9.9 12.7 1.2 15.3 8.8 189 4 196 305 10.3 0 10.5 10.2 08/06/2005 16:30:00 12.3 1 15.6 9.5 11.9 1 14.9 8.8 190 4 194 305 10.5 0 10.8 10.2 08/06/2005 16:40:00 12.3 0.8 14.1 9.5 12 0.9 14.1 9.5 188 4 191 305 10.5 0 10.8 10.2 08/06/2005 16:50:00 12.1 1 14.9 8.8 11.6 1.1 14.5 8.4 190 5 194 305 10.4 0 10.5 10.2 08/06/2005 17:00:00 12 0.9 14.5 9.5 11.6 1.1 14.1 8.8 191 4 185 305 10.1 0 10.5 10 08/06/2005 17:10:00 11 1.1 13.3 6.8 10.3 1.3 13 6.5 193 6 198 305 10 0 10.2 10 08/06/2005 17:20:00 11.7 0.9 14.1 9.1 11.1 1.1 13.7 6.8 192 5 190 305 10.1 0 10.2 10 08/06/2005 17:30:00 12.3 1 14.5 9.5 11.9 1 14.1 8.4 191 5 189 305 10.3 0 10.5 10.2 08/06/2005 17:40:00 11.8 1 14.1 8.4 11.2 1.1 13.7 7.6 194 5 193 305 10.1 0 10.2 10 08/06/2005 17:50:00 10.8 1.1 13.7 7.6 10.1 1.3 13.3 6.8 193 6 200 305 9.9 0 10 9.7 08/06/2005 18:00:00 12.3 0.9 14.9 9.1 11.9 0.9 14.5 8.8 190 4 191 305 10 0 10.2 10 08/06/2005 18:10:00 12.6 1 14.9 9.1 11.6 1.2 14.1 8.4 194 6 200 305 10.1 0 10.5 10 08/06/2005 18:20:00 12.4 1.1 14.5 8.8 11.8 1.3 14.1 8.4 192 5 193 305 10.3 0 10.5 10.2 08/06/2005 18:30:00 12.8 0.9 15.3 10.7 12.4 1 14.9 9.5 190 5 191 305 10.3 0 10.8 10.2 08/06/2005 18:40:00 13 1 16.4 10.7 12.7 1 15.3 9.9 188 4 189 305 10.2 0 10.2 10.2 08/06/2005 18:50:00 12.4 0.8 14.1 10.3 12 1 14.1 8.4 186 4 189 305 10.3 0 10.5 10.2 08/06/2005 19:00:00 12.8 1.1 15.3 9.5 12.4 1.2 14.9 9.1 186 4 191 305 10.3 0 10.5 10.2 08/06/2005 19:10:00 13.6 1 15.6 10.7 13.3 1.1 15.6 10.3 186 3 183 305 10.2 0 10.8 10 08/06/2005 19:20:00 13.8 1 16.4 10.7 13.4 1.1 15.6 9.5 185 4 184 305 10.2 0 10.8 10 08/06/2005 19:30:00 13.8 0.9 15.6 10.7 13.4 1 16.1 10.3 184 4 179 305 10.2 0 10.8 10 08/06/2005 19:40:00 14.3 0.9 16.8 11.5 13.8 1 16.1 10.7 184 4 186 305 10.2 0 10.8 10 08/06/2005 19:50:00 14.3 1.3 18.7 11.5 13.8 1.5 17.6 8.8 184 4 183 305 10 0 10.5 10 08/06/2005 20:00:00 14.7 1.1 16.8 10.3 14.3 1.2 16.4 10.7 185 4 189 305 9.9 0.1 10.5 9.7 08/06/2005 20:10:00 14.7 0.9 17.6 11.1 14.3 1.1 17.2 10.3 185 4 182 305 9.9 0.1 10.2 9.7 08/06/2005 20:20:00 14.5 1 16.8 11.8 14.1 1.2 16.4 9.9 186 4 189 305 9.9 0 10.2 9.7 08/06/2005 20:30:00 14.5 1.1 17.6 11.5 14.1 1.2 16.8 11.5 186 4 188 305 9.9 0 10.2 9.7 08/06/2005 20:40:00 14.7 1 16.8 11.8 14.2 1.2 16.4 10.7 187 3 186 305 9.9 0 10.2 9.7 08/06/2005 20:50:00 14.2 1 17.2 11.1 13.7 1 16.4 11.1 188 4 191 305 9.9 0 10 10 08/06/2005 21:00:00 13.8 1 16.1 11.5 13.4 1 15.3 10.3 189 4 183 305 9.9 0 10 9.7 08/06/2005 21:10:00 13.7 1.1 16.1 9.5 13 1.2 16.4 9.5 192 5 199 305 9.9 0 10 9.7 08/06/2005 21:20:00 13.5 1.3 16.1 9.1 12.9 1.3 16.1 9.1 193 5 193 305 9.8 0 10 9.7 08/06/2005 21:30:00 13 1.2 15.6 8.8 12.4 1.3 15.6 8.4 193 6 197 305 9.8 0 10 9.7 08/06/2005 21:40:00 12.9 1.2 15.6 8.8 12.1 1.3 14.9 8 193 6 194 305 9.7 0 9.7 9.7 08/06/2005 21:50:00 13.1 1.1 15.6 9.5 12.3 1.2 15.3 8.4 193 5 188 305 9.7 0 9.7 9.7 08/06/2005 22:00:00 12.5 1.3 15.6 7.6 11.7 1.5 15.3 7.6 192 5 191 305 9.7 0 10 9.7 08/06/2005 22:10:00 12.3 1.2 14.5 8.4 11.4 1.3 14.1 7.6 193 6 189 305 9.7 0 10 9.7 08/06/2005 22:20:00 12.4 1.1 14.9 8.8 11.5 1.1 14.1 8 193 5 188 305 9.7 0 10 9.7 08/06/2005 22:30:00 12.6 1.3 15.6 8 11.6 1.5 16.1 7.2 196 7 189 305 9.7 0 9.7 9.7 08/06/2005 22:40:00 13.2 1.1 16.1 9.5 12.4 1.3 15.3 9.1 199 6 203 305 9.7 0 9.7 9.5 08/06/2005 22:50:00 13.6 1.2 17.2 9.9 12.7 1.4 17.2 9.1 201 6 200 305 9.6 0 10 9.5 08/06/2005 23:00:00 13 1.3 16.1 9.9 12.1 1.4 15.3 8.8 205 7 197 305 9.6 0 10.2 9.5 08/06/2005 23:10:00 13.7 1.7 17.2 8.8 12.7 1.7 16.4 8 206 6 208 305 9.5 0.1 10 9.2 08/06/2005 23:20:00 13.8 1.1 16.8 11.1 12.8 1.2 15.3 9.9 204 6 207 305 9.3 0.1 10 9.2 08/06/2005 23:30:00 13.1 1.2 16.1 9.9 12.1 1.3 15.6 8.8 206 6 205 305 9.3 0 9.7 9.2 08/06/2005 23:40:00 13.2 1.2 16.1 10.3 12.2 1.4 16.1 8.4 206 6 200 305 9.3 0 9.7 9.2 08/06/2005 23:50:00 12 1.1 15.6 8.4 11.3 1.3 15.3 6.8 202 5 192 305 9.3 0 9.7 9.2 08/07/2005 00:00:00 13.6 1.5 16.1 9.1 12.7 1.6 16.1 8.4 202 5 199 305 9.2 0 9.2 9.2 08/07/2005 00:10:00 13.4 1.7 17.2 8.8 12.5 1.7 16.4 8.4 202 5 197 305 9.2 0 9.5 9.2 08/07/2005 00:20:00 13.7 1.3 16.4 9.1 12.6 1.4 15.6 9.5 204 6 206 305 9.2 0 9.2 9.2 08/07/2005 00:30:00 13.8 1.1 16.8 10.3 13 1.2 16.1 9.9 203 5 208 305 9.2 0 9.2 9.2 08/07/2005 00:40:00 12.4 1.3 16.1 9.1 11.6 1.5 14.5 8 204 5 204 305 9.2 0 9.5 9.2 08/07/2005 00:50:00 12.6 1 14.9 9.5 11.8 1.3 15.3 8.4 205 5 208 305 9.2 0 9.5 9.2 08/07/2005 01:00:00 11.8 1.2 14.9 8.8 10.9 1.3 14.5 7.2 206 6 208 305 9.3 0 9.7 9.2 08/07/2005 01:10:00 11.7 1.1 14.5 8.4 10.8 1.2 13.3 8 205 6 202 305 9.2 0 9.7 9.2 08/07/2005 01:20:00 12.7 1.4 16.1 7.6 11.9 1.3 14.9 8 205 6 198 305 9.2 0 9.5 9.2 08/07/2005 01:30:00 11.7 1.4 14.9 7.2 10.9 1.3 14.5 8 208 6 205 305 9.2 0 9.5 9.2 08/07/2005 01:40:00 12.4 1.2 15.3 9.1 11.3 1.3 14.5 8.4 207 6 210 305 9.2 0 9.5 9.2 08/07/2005 01:50:00 13 1.2 15.6 9.1 12.1 1.3 15.3 9.1 209 6 215 305 9.2 0 9.7 9.2 08/07/2005 02:00:00 11.5 1.7 15.3 7.6 10.6 1.7 14.9 6.8 206 6 208 305 9.2 0 9.5 9.2 08/07/2005 02:10:00 11.9 1.3 14.5 8.4 11 1.4 14.9 7.6 204 6 201 305 9.1 0 9.5 9.2 08/07/2005 02:20:00 11.5 1.2 13.3 7.6 10.7 1.2 13.3 7.2 205 5 208 305 9.1 0 9.2 9.2 08/07/2005 02:30:00 10.5 1.3 13 7.6 9.8 1.2 12.6 6.8 202 6 201 305 9.1 0 9.2 9.2 08/07/2005 02:40:00 11 1.3 13.7 7.2 10.3 1.3 13 6.8 206 6 208 305 9.1 0 9.2 8.9 08/07/2005 02:50:00 11 1.5 14.5 7.6 10.2 1.5 14.1 6.8 205 6 208 305 9.1 0 9.2 8.9 08/07/2005 03:00:00 11.4 1.1 14.1 8.4 10.5 1.3 13.7 6.8 196 6 192 305 9.1 0 9.2 9.2 08/07/2005 03:10:00 11.1 1.2 13.7 8.4 10.4 1.3 13 6.8 196 6 201 305 9.1 0 9.2 8.9 08/07/2005 03:20:00 11.7 1.2 14.5 8 11 1.3 13.7 7.2 197 5 205 305 9.1 0 9.2 8.9 08/07/2005 03:30:00 11.4 1.5 14.1 7.2 10.7 1.6 13.7 6.8 196 6 199 305 9 0 9.5 8.9 08/07/2005 03:40:00 11.7 1 13.7 8 10.9 1.1 13.3 7.2 194 5 196 305 8.9 0 9.5 8.9 08/07/2005 03:50:00 10.2 1.2 12.6 6.5 9.4 1.3 11.8 5.7 191 6 192 305 8.9 0 9.5 8.9 08/07/2005 04:00:00 10.8 1.1 13 7.2 9.9 1.1 12.2 7.2 192 6 185 305 8.9 0 9.2 8.9 08/07/2005 04:10:00 11.7 1 13.3 7.6 11 1.3 13 7.2 190 5 185 305 8.9 0 9.2 8.9 08/07/2005 04:20:00 10.8 1.2 13 7.2 10 1.3 13 6.1 190 6 188 305 8.9 0 9.2 8.7 08/07/2005 04:30:00 11.5 0.9 13.3 7.6 10.7 1.1 13 7.6 188 5 179 305 8.8 0 9.2 8.7 08/07/2005 04:40:00 11.7 1 13.7 8 11.1 1.3 13.3 6.8 187 5 190 305 8.8 0 9.2 8.7 08/07/2005 04:50:00 11.5 0.8 13 8.4 11.1 0.8 13 8 187 4 185 305 8.8 0 9.2 8.7 08/07/2005 05:00:00 11.8 1.1 13.7 7.2 11.1 1.3 13.7 6.8 189 5 184 305 8.8 0 9.2 8.7 08/07/2005 05:10:00 11.4 1 13.3 7.6 10.6 1.2 13.3 7.6 193 5 193 305 8.8 0 9.2 8.7 08/07/2005 05:20:00 10.9 1 13 8 10.2 1.2 12.6 7.6 193 6 201 305 8.8 0 9.2 8.7 08/07/2005 05:30:00 12 0.9 14.1 8.8 11.3 1.1 13.7 8 194 5 193 305 8.7 0 8.9 8.4 08/07/2005 05:40:00 11 1 13.3 7.2 10.3 1.2 13 6.8 195 5 201 305 8.7 0 9.2 8.4 08/07/2005 05:50:00 11.4 0.9 13 8 10.8 1.2 13 6.8 195 4 198 305 8.6 0 8.9 8.2 08/07/2005 06:00:00 10.8 1 13 7.6 10.1 1.2 12.6 6.8 194 6 196 305 8.4 0 8.7 8.4 08/07/2005 06:10:00 11 1.3 13.3 6.8 10.4 1.3 13 6.1 191 6 198 305 8.6 0 8.9 8.4 08/07/2005 06:20:00 11.5 1.3 13.7 7.6 10.9 1.5 13.3 7.2 188 6 184 305 8.6 0 8.7 8.4 08/07/2005 06:30:00 12.3 0.7 13.7 10.3 11.9 0.8 13.3 8.8 186 3 186 305 8.5 0 8.9 8.2 08/07/2005 06:40:00 12.2 1 14.5 9.1 11.4 1.2 13.7 7.2 189 6 192 305 8.4 0 8.4 8.4 08/07/2005 06:50:00 11.6 1.1 14.1 7.6 11 1.1 13.3 8 189 5 200 305 8.5 0 8.9 8.4 08/07/2005 07:00:00 12.6 0.8 14.1 9.5 12.2 1 14.1 8 184 4 183 305 8.4 0 8.7 8.2 08/07/2005 07:10:00 12 1.1 14.1 8.4 11.4 1.2 13.3 7.6 188 5 190 305 8.4 0 8.4 8.2 08/07/2005 07:20:00 11.7 0.9 13.3 9.1 11.3 1 13.3 8 183 6 187 305 8.4 0 8.7 8.2 08/07/2005 07:30:00 11.7 0.7 13 9.1 11.3 0.8 13.3 9.1 182 5 176 305 8.2 0 8.7 8.2 08/07/2005 07:40:00 11.4 0.7 13 9.1 11 0.8 12.6 8.4 184 5 184 305 8.3 0 8.4 8.2 08/07/2005 07:50:00 11.3 0.8 13 8.4 10.9 1 13.3 8 181 5 188 305 8.2 0 8.7 8.2 08/07/2005 08:00:00 11.6 1 13.3 7.6 11.1 1.1 13.3 7.2 182 6 184 305 8.2 0.1 8.7 8.2 08/07/2005 08:10:00 11 0.8 12.2 8.8 10.7 1 12.6 8 176 4 174 305 8.3 0.1 8.9 8.2 08/07/2005 08:20:00 10.7 1 12.6 8 10.5 1 12.6 7.2 182 5 186 305 8.4 0.1 8.9 8.2 08/07/2005 08:30:00 10.9 0.6 12.2 9.5 10.6 0.8 12.2 7.6 183 5 184 305 8.2 0.1 8.9 8.2 08/07/2005 08:40:00 10 0.7 11.8 8 9.7 0.9 11.8 7.2 179 5 177 305 8.3 0.1 8.9 8.2 08/07/2005 08:50:00 11.1 0.6 12.6 8 10.6 0.9 12.2 6.8 187 4 186 305 8.2 0.1 8.9 8.2 08/07/2005 09:00:00 9.4 1.2 11.5 5.7 8.7 1.2 11.8 5.7 190 6 189 305 8.3 0.1 8.9 8.2 08/07/2005 09:10:00 10.2 0.9 11.8 7.2 9.6 1.1 11.8 6.8 188 6 181 305 8.2 0.1 8.7 7.9 08/07/2005 09:20:00 10.1 1.1 11.8 6.8 9.6 1.3 11.8 5.7 186 6 198 305 8.1 0 8.7 7.9 08/07/2005 09:30:00 9.5 0.7 11.1 7.2 9.3 0.9 11.1 6.5 178 5 177 305 8.2 0 8.9 7.9 08/07/2005 09:40:00 8.8 0.6 9.9 6.5 8.6 0.7 9.9 6.1 181 5 187 305 8.2 0 8.4 8.2 08/07/2005 09:50:00 8.5 0.8 10.3 6.1 8.2 1 10.3 5.3 180 6 184 305 8.2 0 8.4 8.2 08/07/2005 10:00:00 8.5 0.7 10.3 6.1 8.3 0.8 10.3 6.1 177 5 179 305 8.2 0 8.4 8.2 08/07/2005 10:10:00 7.6 0.6 8.8 5.3 7.8 0.8 9.5 4.6 170 6 182 305 8.4 0 8.7 8.2 08/07/2005 10:20:00 7.5 0.7 9.5 5.3 7.5 0.9 9.5 4.6 172 6 174 305 8.4 0 8.7 8.2 08/07/2005 10:30:00 7.8 0.7 9.9 4.9 7.9 0.8 9.9 5.7 171 6 173 305 8.4 0 8.9 8.2 08/07/2005 10:40:00 8.5 0.6 10.3 6.8 8.3 0.7 10.3 6.5 182 5 180 305 8.4 0 9.2 8.2 08/07/2005 10:50:00 7.5 0.7 8.8 5.3 7.3 0.8 9.1 4.9 188 6 179 305 8.5 0 8.7 8.2 08/07/2005 11:00:00 7.5 0.6 8.8 5.3 7.3 0.7 8.8 4.9 188 5 188 305 8.6 0 8.9 8.4 08/07/2005 11:10:00 8.3 0.8 9.9 5.7 8 0.8 9.9 5.3 189 7 193 305 8.7 0 8.9 8.4 08/07/2005 11:20:00 9.2 0.6 10.7 6.8 8.8 0.7 10.3 6.1 194 6 186 305 8.6 0 8.9 8.4 08/07/2005 11:30:00 9.3 0.7 11.1 6.5 9 0.9 11.1 5.7 185 5 180 305 8.6 0 8.9 8.4 08/07/2005 11:40:00 8.9 0.5 10.3 6.8 8.7 0.7 9.9 6.1 183 5 183 305 8.8 0 9.2 8.7 08/07/2005 11:50:00 8.9 0.5 10.3 7.2 8.8 0.6 9.9 6.5 185 5 190 305 8.9 0 9.2 8.9 08/07/2005 12:00:00 8.1 0.7 10.3 6.1 7.8 0.8 9.1 5.7 187 6 192 305 9.1 0.1 9.2 8.9 08/07/2005 12:10:00 8 0.4 9.1 6.1 7.9 0.5 9.1 5.7 188 5 181 305 9.2 0 9.5 9.2 08/07/2005 12:20:00 8.4 0.6 9.5 6.1 8.1 0.8 9.9 5.7 187 5 184 305 9.4 0 9.7 9.2 08/07/2005 12:30:00 8.8 0.6 10.3 5.7 8.7 0.6 9.9 6.5 187 4 192 305 9.1 0 9.2 8.9 08/07/2005 12:40:00 8.9 0.6 10.3 6.5 8.7 0.7 10.3 6.5 186 5 185 305 9.1 0 9.2 8.9 08/07/2005 12:50:00 8.7 0.4 9.9 7.2 8.6 0.5 9.5 6.8 181 5 184 305 9 0 9.2 8.9 08/07/2005 13:00:00 8.5 0.7 9.9 6.5 8.4 0.8 9.9 5.7 185 5 181 305 9.1 0 9.5 8.9 08/07/2005 13:10:00 7.9 0.9 9.9 5.3 7.9 0.9 9.9 4.9 179 6 174 305 9.3 0.1 9.7 9.2 08/07/2005 13:20:00 7.3 0.5 8.8 5.7 7.1 0.6 8.8 4.9 181 5 176 305 9.5 0 9.7 9.5 08/07/2005 13:30:00 6.5 0.8 8 3.8 6.3 0.9 8 3.8 184 6 183 305 9.8 0 10 9.5 08/07/2005 13:40:00 5.5 0.7 6.8 3.4 5.4 0.8 7.2 3.4 183 7 185 305 10 0.1 10.2 10 08/07/2005 13:50:00 5.2 0.5 6.5 3.4 5.3 0.5 6.5 3.8 181 5 184 305 10 0 10.2 10 08/07/2005 14:00:00 5 0.7 6.5 3.4 4.9 0.7 6.5 3 188 9 192 305 10.5 0 10.8 10.2 08/07/2005 14:10:00 5 0.7 6.8 3 4.9 0.8 6.8 3 184 8 175 305 10.7 0 11 10.5 08/07/2005 14:20:00 5.9 0.8 7.6 3.8 5.9 0.8 8.4 3.8 184 8 186 305 10.7 0 11 10.5 08/07/2005 14:30:00 6.2 0.8 8 3.8 6.1 0.8 8 3.8 186 8 181 305 10.6 0 10.8 10.5 08/07/2005 14:40:00 5.9 0.9 8 3.8 5.6 0.9 7.6 3.8 189 8 186 305 10.8 0.1 11 10.5 08/07/2005 14:50:00 5 0.5 6.1 3.4 4.9 0.6 6.1 3 184 8 191 305 11.2 0 11.3 11 08/07/2005 15:00:00 5.2 0.8 6.8 3 4.9 0.8 6.8 2.6 187 8 192 305 11.3 0 11.6 11 08/07/2005 15:10:00 5.5 0.7 7.6 3.8 5.1 0.7 7.2 3.4 184 10 177 305 11.4 0.2 11.8 11 08/07/2005 15:20:00 5.3 0.9 7.6 1.9 5.2 0.9 7.2 2.3 179 15 172 305 11.8 0 12.1 11.6 08/07/2005 15:30:00 5 0.9 8 3 6.6 1.3 9.5 3.8 149 9 148 305 13 0.4 13.4 11.8 08/07/2005 15:40:00 7.5 2.5 11.1 3.4 8.1 1.7 11.1 4.2 141 10 137 305 13.6 0 14 13.4 08/07/2005 15:50:00 8.2 1.5 10.3 4.2 8.4 1.1 10.3 4.9 135 7 129 305 13.2 0 13.7 13.2 08/07/2005 16:00:00 7.8 1.5 11.1 4.2 8.7 1.1 11.1 5.7 141 8 141 305 12.8 0 13.2 12.6 08/07/2005 16:10:00 9.8 1.4 12.6 4.9 9.7 0.9 11.5 6.8 138 5 140 305 12.4 0 12.9 12.1 08/07/2005 16:20:00 9.3 1.7 13 4.2 9.7 1.3 12.6 5.7 140 7 134 305 11.8 0.1 12.4 11.6 08/07/2005 16:30:00 10.5 1.2 13.7 7.2 10.4 1 13 8 135 6 138 305 11.6 0.2 11.8 11 08/07/2005 16:40:00 8.9 0.9 11.1 5.7 8.9 0.8 10.7 6.1 134 7 144 305 11.3 0 11.6 11 08/07/2005 16:50:00 8.9 1.7 12.2 5.3 9.2 1.3 11.8 5.7 140 7 139 305 11.6 0 11.6 11.3 08/07/2005 17:00:00 9.3 1.6 12.2 4.2 9.2 1.2 11.5 5.7 137 8 134 305 11.4 0 11.6 11.3 08/07/2005 17:10:00 9.6 1.2 12.2 6.1 9.6 1 11.8 6.8 136 7 135 305 11.4 0 11.6 11.3 08/07/2005 17:20:00 8.9 1.1 11.8 5.7 8.8 0.9 11.1 6.1 137 7 136 305 11.2 0 11.3 11 08/07/2005 17:30:00 7.8 1.4 11.1 4.2 7.8 1.2 10.7 4.9 136 9 136 305 11.2 0 11.3 11 08/07/2005 17:40:00 8.7 1.7 12.6 3.8 8.8 1.3 12.2 5.3 139 9 149 305 11.1 0 11.3 10.8 08/07/2005 17:50:00 9.4 1.7 14.1 5.3 9.3 1.3 13 5.7 137 8 137 305 10.9 0 11 10.8 08/07/2005 18:00:00 9.6 1.3 13 5.7 9.4 1.2 12.2 6.1 135 8 140 305 10.7 0 10.8 10.5 08/07/2005 18:10:00 10 1.5 13.3 6.5 9.6 1.4 13 5.7 134 8 149 305 10.6 0 10.8 10.5 08/07/2005 18:20:00 10.5 1.1 13.3 8 10.1 1 12.6 7.6 134 6 139 305 10.6 0 10.8 10.5 08/07/2005 18:30:00 8.6 1 11.5 6.1 8.6 1 11.5 6.1 128 7 137 305 10.6 0 10.8 10.5 08/07/2005 18:40:00 9 1.1 12.2 6.5 8.9 1.1 11.8 6.1 127 8 125 305 10.6 0 10.8 10.5 08/07/2005 18:50:00 10 1 12.6 7.6 9.8 1 12.6 7.2 131 8 127 305 10.6 0 10.8 10.5 08/07/2005 19:00:00 10.6 1.3 13.7 6.5 10.5 1.3 13.3 6.5 130 9 141 305 10.5 0 10.8 10.5 08/07/2005 19:10:00 11.9 1 14.5 8.8 11.7 0.9 14.1 9.1 126 5 127 305 10.4 0 10.5 10.2 08/07/2005 19:20:00 12 0.8 14.1 9.5 11.8 0.9 14.1 9.1 123 5 133 305 10.4 0 10.5 10.2 08/07/2005 19:30:00 13.1 1 15.3 10.3 12.8 1 15.3 9.9 124 5 124 305 10.5 0 10.5 10.2 08/07/2005 19:40:00 13.3 1.2 16.8 9.1 13.1 1.2 15.6 9.5 126 6 122 305 10.4 0 10.5 10.2 08/07/2005 19:50:00 12 1.1 14.5 8 11.8 1.2 14.1 8 125 5 130 305 10.3 0 10.5 10.2 08/07/2005 20:00:00 12.5 1.1 15.3 9.9 12.3 1.1 14.5 9.1 122 5 118 305 10.3 0 10.2 10.2 08/07/2005 20:10:00 12.3 1.1 15.3 9.1 11.9 1.1 14.9 8.8 122 5 121 305 10.3 0 10.5 10.2 08/07/2005 20:20:00 10.1 1.7 13.7 6.1 9.9 1.7 13.3 5.7 121 8 126 305 10.3 0 10.2 10.2 08/07/2005 20:30:00 9 1.6 14.1 5.3 8.9 1.6 14.5 5.3 115 12 112 305 10.2 0 10.2 10.2 08/07/2005 20:40:00 9.5 1.8 14.5 4.6 9.2 1.7 14.9 4.6 112 12 99 305 10.2 0 10.2 10.2 08/07/2005 20:50:00 9.5 1.8 13.7 4.9 9.2 1.7 13.3 4.9 114 13 124 305 10.2 0 10.2 10.2 08/07/2005 21:00:00 9.6 1.6 13.7 5.7 9.4 1.7 13.7 3.8 124 13 122 305 10.3 0 10.5 10.2 08/07/2005 21:10:00 12.3 1.3 15.6 8 12 1.3 14.9 7.2 124 6 121 305 10.3 0 10.5 10.2 08/07/2005 21:20:00 13.4 1.3 17.2 9.1 13.2 1.5 16.8 8.8 125 7 120 305 10.4 0 10.5 10.2 08/07/2005 21:30:00 10.8 1.5 14.9 6.1 10.7 1.5 14.5 7.2 126 12 112 305 10.5 0 10.5 10.5 08/07/2005 21:40:00 11.4 2.1 15.6 5.7 11.5 1.8 16.4 7.6 132 11 131 305 10.4 0 10.5 10.2 08/07/2005 21:50:00 8.7 1.7 12.6 4.2 9 1.5 12.6 4.9 140 11 152 305 10.3 0 10.8 10.2 08/07/2005 22:00:00 7.4 1.8 13.3 3.4 8.2 1.5 12.2 4.6 150 15 120 305 10.3 0 10.5 10.2 08/07/2005 22:10:00 9.9 2.2 15.3 5.7 10.9 1.5 14.9 7.6 147 10 137 305 10.2 0 10.2 10.2 08/07/2005 22:20:00 11.5 2.3 17.9 6.5 11.9 1.9 17.6 6.5 140 9 135 305 10.2 0 10.2 10.2 08/07/2005 22:30:00 11.5 2.2 16.4 5.7 11.4 1.8 16.1 7.2 140 9 134 305 10.2 0 10.5 10.2 08/07/2005 22:40:00 11.8 1.7 16.4 5.3 11.8 1.5 16.1 8 137 8 128 305 10.3 0 10.2 10.2 08/07/2005 22:50:00 12 1.7 16.4 7.6 11.9 1.5 16.1 8.8 138 7 131 305 10.3 0 10.2 10.2 08/07/2005 23:00:00 13.5 1.5 17.2 8.4 13.1 1.3 16.4 9.5 137 7 133 305 10.3 0 10.2 10.2 08/07/2005 23:10:00 14.1 1.5 18.3 9.5 13.7 1.3 17.6 9.5 138 6 139 305 10.4 0 10.5 10.2 08/07/2005 23:20:00 14 1.5 17.6 9.5 13.8 1.3 18.3 10.3 139 7 132 305 10.4 0 10.5 10.2 08/07/2005 23:30:00 13.5 1.7 18.7 8 13.2 1.5 17.2 9.9 138 7 145 305 10.4 0 10.5 10.2 08/07/2005 23:40:00 11.9 1.9 16.4 6.5 11.6 1.7 15.3 6.1 138 9 137 305 10.3 0 10.5 10.2 08/07/2005 23:50:00 13.1 2.3 17.6 6.1 12.9 1.8 16.8 7.6 138 8 143 305 10.5 0 10.5 10.2 08/08/2005 00:00:00 12 2.3 17.9 6.1 12 1.9 17.6 8 139 9 132 305 10.5 0 11 10.5 08/08/2005 00:10:00 14.8 2.1 20.6 9.9 14.4 1.9 19.9 10.3 137 8 138 305 10.5 0 10.8 10.5 08/08/2005 00:20:00 15.3 1.7 19.5 10.7 15.1 1.6 19.9 10.7 134 9 140 305 10.5 0 10.8 10.5 08/08/2005 00:30:00 15.5 1.7 19.9 11.1 15.2 1.7 19.5 10.7 133 8 138 305 10.6 0 10.8 10.5 08/08/2005 00:40:00 15.8 1.8 20.6 11.1 15.2 1.7 20.6 10.3 136 7 138 305 10.6 0 10.8 10.5 08/08/2005 00:50:00 16.3 1.9 20.2 10.3 16 1.5 19.9 11.1 138 7 142 305 10.6 0 10.8 10.5 08/08/2005 01:00:00 16.6 1.7 21 9.5 16.1 1.6 19.9 11.8 137 6 137 305 10.6 0 10.8 10.5 08/08/2005 01:10:00 16 1.7 19.1 11.1 15.6 1.5 20.2 11.8 138 6 150 305 10.4 0 10.5 10.2 08/08/2005 01:20:00 15.7 1.7 20.2 9.9 15.3 1.7 19.9 10.7 137 7 143 305 10.6 0 10.8 10.5 08/08/2005 01:30:00 14.7 1.8 19.1 9.9 14.2 1.7 19.1 8.4 135 8 133 305 10.6 0 10.8 10.5 08/08/2005 01:40:00 14.4 1.8 19.1 9.9 14.1 1.7 18.7 9.1 136 8 138 305 10.6 0 10.8 10.5 08/08/2005 01:50:00 13.8 2.1 18.3 7.6 13.7 1.8 17.9 8.4 137 8 138 305 10.6 0 10.8 10.5 08/08/2005 02:00:00 14.8 2 19.5 9.5 14.7 1.7 18.3 9.5 137 8 142 305 10.6 0 10.8 10.5 08/08/2005 02:10:00 14.4 2.2 19.5 8.8 14.4 2.2 19.9 9.1 139 8 145 305 10.5 0 10.5 10.2 08/08/2005 02:20:00 15 2.2 19.9 7.6 14.9 1.9 19.5 9.1 139 8 143 305 10.4 0 10.5 10.2 08/08/2005 02:30:00 13.5 2.4 18.3 7.6 13.4 1.9 17.9 8.8 138 10 138 305 10.4 0 10.5 10.2 08/08/2005 02:40:00 13.7 2 19.9 8 13.6 1.9 18.3 9.5 138 9 114 305 10.4 0 10.5 10.2 08/08/2005 02:50:00 12.5 2.3 17.6 6.5 12.9 1.9 17.6 8.4 141 10 120 305 10.4 0 10.5 10.2 08/08/2005 03:00:00 12.1 2.4 17.6 7.2 12.6 1.9 17.2 6.8 144 10 137 305 10.5 0 10.8 10.2 08/08/2005 03:10:00 11.4 2.1 17.9 6.8 12 1.7 16.8 7.2 145 10 134 305 10.4 0 10.5 10.2 08/08/2005 03:20:00 11.7 2.1 16.8 6.8 13.1 1.6 17.6 8.4 148 9 147 305 10.4 0 10.5 10.2 08/08/2005 03:30:00 11.2 1.8 17.6 7.2 12.4 1.7 17.2 8 150 11 141 305 10.4 0 10.5 10.2 08/08/2005 03:40:00 11.8 2 17.2 7.6 13.8 1.9 18.7 9.1 151 8 150 305 10.4 0 10.5 10.2 08/08/2005 03:50:00 10.8 1.7 15.6 6.1 13.2 1.5 16.8 9.5 152 7 154 305 10.6 0 10.8 10.5 08/08/2005 04:00:00 11.6 1.7 18.3 8 14.4 1.5 18.7 10.7 152 6 139 305 10.8 0 10.8 10.5 08/08/2005 04:10:00 12.4 1.5 16.8 8 16.7 1.7 21 11.5 154 5 152 305 11.1 0 11.3 10.8 08/08/2005 04:20:00 12.3 1.6 17.6 7.2 16.5 1.5 20.2 11.1 155 6 152 305 11.3 0 11.3 11 08/08/2005 04:30:00 10.9 1.7 16.4 6.8 15.4 1.6 19.1 11.5 156 6 143 305 11.2 0 11.3 11 08/08/2005 04:40:00 11.8 1.9 18.7 8 14.8 1.9 20.2 9.1 160 8 174 305 11.2 0 11.3 11 08/08/2005 04:50:00 12.5 2 18.7 8 15.2 1.7 19.9 11.1 159 8 168 305 11.1 0 11.3 11 08/08/2005 05:00:00 12.2 1.7 17.6 8.4 14.8 1.6 19.1 10.3 159 7 163 305 11.1 0 11.3 11 08/08/2005 05:10:00 12.6 1.7 17.9 8 15.6 1.7 20.6 11.1 158 7 170 305 11.1 0 11.3 11 08/08/2005 05:20:00 12.9 1.5 16.4 8.4 16.1 1.7 20.6 11.5 157 7 145 305 11.1 0 11.3 11 08/08/2005 05:30:00 11.4 2 17.6 7.2 14.3 1.6 19.1 9.9 159 8 167 305 11.2 0 11.3 11 08/08/2005 05:40:00 12.2 1.8 17.6 7.2 15.3 1.6 20.2 11.5 157 7 164 305 11.2 0 11.3 11 08/08/2005 05:50:00 12.4 1.7 18.7 7.6 15.5 1.8 20.2 10.3 158 7 150 305 11.2 0 11.3 11 08/08/2005 06:00:00 11.7 1.7 17.2 6.5 15 1.7 18.7 10.7 158 7 176 305 11.2 0 11.3 11 08/08/2005 06:10:00 11.3 1.6 16.1 7.2 14.5 1.7 20.6 9.5 158 7 150 305 11.2 0 11.3 11 08/08/2005 06:20:00 11.5 1.6 16.4 7.6 15.1 1.7 20.6 10.7 157 7 162 305 11.3 0 11.3 11.3 08/08/2005 06:30:00 11 1.6 16.8 7.2 14.5 1.5 19.5 9.9 157 7 149 305 11.3 0 11.3 11.3 08/08/2005 06:40:00 11.5 1.7 16.4 6.8 15 1.7 19.9 11.1 156 8 145 305 11.4 0 11.3 11.3 08/08/2005 06:50:00 10.9 1.6 16.4 7.2 14.3 1.4 18.3 11.1 157 8 169 305 11.3 0 11.3 11.3 08/08/2005 07:00:00 11.1 1.6 16.1 6.8 14.3 1.5 17.9 10.3 158 8 170 305 11.2 0 11.3 11 08/08/2005 07:10:00 11.3 1.7 16.8 7.2 13.7 1.5 17.9 9.9 159 7 160 305 11.1 0 11.3 11 08/08/2005 07:20:00 10.7 2.1 19.1 6.5 13.3 1.9 19.9 8 160 7 176 305 11.1 0 11.3 11 08/08/2005 07:30:00 10.6 1.7 16.1 6.1 13.2 1.5 17.6 9.1 159 8 165 305 11.2 0 11.3 11 08/08/2005 07:40:00 10.4 1.4 14.5 6.8 13.7 1.3 17.6 9.5 158 7 151 305 11.2 0 11.3 11 08/08/2005 07:50:00 10.8 1.5 16.1 7.2 13.9 1.2 17.6 10.7 157 7 151 305 11.2 0 11.3 11 08/08/2005 08:00:00 10.4 1.8 14.9 6.8 13 1.5 16.8 9.1 159 7 168 305 11.2 0 11.3 11 08/08/2005 08:10:00 10.2 1.7 16.4 6.8 13.4 1.3 18.3 8.8 158 8 176 305 11.4 0 11.6 11.3 08/08/2005 08:20:00 9.6 1.5 14.5 6.1 12.5 1.2 16.1 8.8 159 7 169 305 11.4 0 11.6 11.3 08/08/2005 08:30:00 10 1.5 14.9 6.5 13.3 1.3 17.6 9.1 159 7 160 305 11.4 0 11.6 11.3 08/08/2005 08:40:00 10.3 1.7 16.1 7.2 13.4 1.5 17.2 9.5 159 7 156 305 11.4 0 11.6 11.3 08/08/2005 08:50:00 10.5 1.5 14.5 6.5 13.4 1.5 17.2 9.5 158 7 163 305 11.4 0 11.6 11.3 08/08/2005 09:00:00 10.6 1.5 17.6 7.2 14.3 1.5 18.3 11.1 156 6 152 305 11.5 0 11.6 11.3 08/08/2005 09:10:00 10.5 1.5 14.9 6.8 13.1 1.5 16.8 9.1 159 7 155 305 11.6 0 11.6 11.6 08/08/2005 09:20:00 10.4 1.6 16.1 6.8 13.2 1.3 17.2 9.1 158 8 169 305 11.7 0 11.8 11.6 08/08/2005 09:30:00 10.8 1.4 14.9 6.5 14.1 1.5 17.6 9.1 157 7 171 305 11.8 0 11.8 11.6 08/08/2005 09:40:00 10.5 1.7 17.2 6.5 13.3 1.5 16.8 9.9 158 8 163 305 11.7 0 11.8 11.6 08/08/2005 09:50:00 11 1.8 16.1 6.5 13.8 1.6 17.6 9.1 161 7 173 305 11.8 0 11.8 11.6 08/08/2005 10:00:00 11 1.7 16.8 6.1 14.4 1.9 20.2 10.7 158 7 165 305 11.8 0 11.8 11.6 08/08/2005 10:10:00 11.3 1.6 16.4 7.2 16 1.3 19.5 12.6 154 5 139 305 11.7 0 11.8 11.6 08/08/2005 10:20:00 11.5 1.7 17.6 8 16.2 1.7 20.2 11.5 154 6 153 305 11.7 0 11.8 11.6 08/08/2005 10:30:00 11.1 1.7 17.6 6.8 15 1.8 19.5 9.1 157 7 168 305 11.8 0 11.8 11.6 08/08/2005 10:40:00 11.1 1.5 15.6 7.2 14.7 1.5 19.9 10.7 155 7 162 305 11.8 0 11.8 11.6 08/08/2005 10:50:00 11 1.7 16.4 6.5 14.1 1.5 18.3 9.9 157 7 165 305 11.8 0 11.8 11.6 08/08/2005 11:00:00 11 1.8 17.6 6.8 13.7 1.8 18.3 9.5 159 7 168 305 11.8 0 11.8 11.3 08/08/2005 11:10:00 10.7 1.6 15.3 6.5 14.1 1.7 18.3 9.5 157 7 146 305 11.8 0 12.1 11.6 08/08/2005 11:20:00 10.9 1.5 14.9 7.6 14.7 1.6 17.9 10.7 156 7 165 305 12.1 0 12.1 11.8 08/08/2005 11:30:00 9.8 1.5 14.5 6.5 12.8 1.5 17.2 8 157 8 165 305 12.3 0 12.4 12.1 08/08/2005 11:40:00 9.8 1.7 14.5 6.1 12.7 1.5 16.1 8.8 158 6 163 305 12.3 0 12.4 12.1 08/08/2005 11:50:00 10.6 1.8 15.3 6.1 13.1 1.5 16.8 9.1 161 7 171 305 12.3 0 12.4 12.1 08/08/2005 12:00:00 10.4 1.6 14.5 6.5 13.1 1.6 17.9 8.4 160 8 154 305 12.4 0 12.4 12.4 08/08/2005 12:10:00 10.8 1.9 16.4 7.2 13.4 1.6 18.3 9.1 160 7 165 305 12.5 0 12.6 12.4 08/08/2005 12:20:00 10.1 1.6 14.9 6.5 12.9 1.5 18.3 9.5 158 8 146 305 12.6 0 12.6 12.4 08/08/2005 12:30:00 9.8 1.5 14.5 6.8 12.5 1.3 16.8 9.1 158 8 168 305 12.4 0 12.6 12.4 08/08/2005 12:40:00 9.5 1.5 15.3 6.1 12.2 1.4 16.1 8.8 157 8 159 305 12.4 0 12.6 12.4 08/08/2005 12:50:00 9.1 1.6 13.7 5.3 11.7 1.5 16.4 6.8 157 8 154 305 12.4 0 12.6 12.4 08/08/2005 13:00:00 8.7 1.6 14.9 5.3 11.4 1.5 15.3 7.6 156 8 155 305 12.5 0 12.6 12.4 08/08/2005 13:10:00 8.9 1.5 14.5 5.3 11.8 1.4 15.3 8 154 7 163 305 12.6 0 12.9 12.4 08/08/2005 13:20:00 9.1 1.5 13.3 5.3 11.9 1.5 16.4 8 156 8 171 305 12.7 0 12.9 12.6 08/08/2005 13:30:00 9.3 1.5 14.1 6.1 12.5 1.4 16.4 9.5 154 6 163 305 12.8 0 12.9 12.6 08/08/2005 13:40:00 9 1.6 13.7 5.3 11.7 1.5 15.3 6.8 156 8 149 305 12.8 0 13.2 12.9 08/08/2005 13:50:00 8.6 1.6 13 4.9 11.6 1.4 14.9 8 153 6 146 305 13 0 13.2 12.9 08/08/2005 14:00:00 7.9 1.3 12.6 4.6 10.3 1.1 13 6.8 156 8 150 305 13 0 13.2 12.9 08/08/2005 14:10:00 8.5 1.7 13.3 4.6 11 1.5 14.5 7.2 158 9 175 305 13.2 0 13.4 13.2 08/08/2005 14:20:00 8.7 1.7 13.7 5.3 11.4 1.5 15.3 7.2 158 8 145 305 13.1 0 13.4 13.2 08/08/2005 14:30:00 8.5 1.7 15.3 4.9 11.1 1.6 16.8 7.6 154 7 152 305 13 0 13.2 13.2 08/08/2005 14:40:00 8.5 1.5 13.3 5.3 11.9 1.5 14.9 8 157 6 166 305 13 0 13.2 12.9 08/08/2005 14:50:00 8.3 1.6 13.3 4.9 11 1.5 16.1 7.2 154 8 157 305 13.2 0 13.4 13.2 08/08/2005 15:00:00 8 1.3 11.5 4.6 10.9 1.4 14.1 6.8 155 7 140 305 13.3 0 13.4 13.2 08/08/2005 15:10:00 8.4 1.5 12.6 4.9 10.3 1.2 13.3 6.5 151 7 141 305 13 0 13.2 12.9 08/08/2005 15:20:00 8.2 1.6 12.2 4.2 9.3 1.1 12.6 6.1 145 11 137 305 12.6 0.1 13.2 12.4 08/08/2005 15:30:00 8.6 1.7 13.3 4.6 9.4 1.3 12.2 6.5 145 9 144 305 12.4 0 12.4 12.1 08/08/2005 15:40:00 8.2 1.5 12.6 4.6 10.3 1.1 13 7.2 151 7 143 305 12.3 0 12.4 12.1 08/08/2005 15:50:00 8.8 1.6 13 4.9 10.5 1.3 14.5 7.2 149 8 149 305 12.2 0 12.4 12.1 08/08/2005 16:00:00 8.5 1.5 12.6 4.6 9.9 1.1 13.3 7.2 148 7 147 305 12 0 12.1 11.8 08/08/2005 16:10:00 8.3 1.4 12.2 4.9 8.9 1.2 12.6 5.7 145 9 144 305 11.9 0 11.8 11.8 08/08/2005 16:20:00 9.1 1.6 13.3 4.9 9.2 1.3 12.6 5.3 141 10 141 305 11.8 0 11.8 11.6 08/08/2005 16:30:00 7.8 1.5 11.5 4.2 8.4 1.1 11.5 5.7 145 9 134 305 11.8 0 11.8 11.6 08/08/2005 16:40:00 7.8 1.5 11.1 4.6 9 1.1 11.8 6.5 149 9 140 305 12 0 12.1 11.8 08/08/2005 16:50:00 7.2 1.3 10.3 3.8 8.7 1 11.8 5.7 150 8 158 305 12.1 0 12.1 11.8 08/08/2005 17:00:00 6.7 1.3 11.1 4.2 7.5 1.1 10.3 4.6 146 10 140 305 12 0 12.1 11.8 08/08/2005 17:10:00 7.7 1.6 11.1 3.8 7.9 1.3 11.1 4.2 140 10 141 305 11.9 0 12.1 11.6 08/08/2005 17:20:00 7.1 1.5 10.7 3.8 7.7 1.1 10.7 4.9 146 11 132 305 11.9 0 11.8 11.8 08/08/2005 17:30:00 7.6 1.6 12.2 4.6 7.9 1.3 11.8 5.3 145 9 146 305 11.7 0 11.8 11.6 08/08/2005 17:40:00 8 1.5 11.5 4.2 8.3 1.2 11.8 5.7 144 10 139 305 11.6 0 11.6 11.3 08/08/2005 17:50:00 7 1.2 10.7 4.2 7.3 1 10.7 4.9 145 10 143 305 11.4 0 11.6 11.3 08/08/2005 18:00:00 8.2 1.9 12.2 4.2 8.3 1.5 11.8 4.9 141 9 139 305 11.4 0 11.6 11 08/08/2005 18:10:00 9.6 1.9 14.1 4.2 9.7 1.4 13.7 6.1 142 9 134 305 11.2 0 11.3 11 08/08/2005 18:20:00 8.6 1.8 14.1 4.9 9.6 1.7 14.1 6.1 148 11 140 305 11.2 0 11.3 11 08/08/2005 18:30:00 9.4 1.7 14.1 5.3 11.7 1.3 14.5 8.4 153 7 164 305 11.4 0 11.3 11.3 08/08/2005 18:40:00 8.8 1.5 13.3 5.7 11.5 1.1 14.5 8.4 155 7 143 305 11.3 0 11.3 11 08/08/2005 18:50:00 9.3 1.5 13.7 6.5 12.1 1.1 15.3 9.1 154 7 131 305 11.1 0 11.3 11 08/08/2005 19:00:00 9.5 1.5 15.6 6.5 12.7 1 15.6 9.9 155 6 148 305 11 0 11 11 08/08/2005 19:10:00 9.1 1.3 13.3 6.1 13 1.1 15.6 8.8 157 5 148 305 11 0 11 10.8 08/08/2005 19:20:00 9.1 1.5 14.5 6.1 12.4 1.3 15.6 8.8 158 6 152 305 10.8 0 11 10.8 08/08/2005 19:30:00 9.2 1.5 13.7 5.7 12 1.5 15.3 8 157 7 151 305 10.8 0 10.8 10.5 08/08/2005 19:40:00 9.1 1.2 12.6 6.5 12.6 1.2 15.3 8.4 159 6 151 305 10.6 0 10.8 10.5 08/08/2005 19:50:00 8.8 1.5 13.7 5.7 11.9 1.5 15.6 7.6 157 7 163 305 10.5 0 10.5 10.5 08/08/2005 20:00:00 9.2 1.5 14.1 6.1 12 1.6 15.6 8 156 7 154 305 10.4 0 10.5 10.2 08/08/2005 20:10:00 8.7 1.3 13 5.7 12 1.3 14.9 8.8 158 6 144 305 10.4 0 10.5 10.2 08/08/2005 20:20:00 8.5 1.5 13.3 4.9 11.3 1.3 14.5 8.4 157 7 141 305 10.4 0 10.5 10.2 08/08/2005 20:30:00 9.3 1.8 15.6 5.3 11.8 1.4 16.8 7.6 155 8 145 305 10.5 0 10.8 10.2 08/08/2005 20:40:00 9.7 1.8 15.3 6.1 12.2 1.4 17.2 8.8 155 8 147 305 10.5 0 10.8 10.5 08/08/2005 20:50:00 10.5 1.8 16.4 6.5 12.9 1.3 16.8 9.5 152 7 148 305 10.4 0 10.5 10.2 08/08/2005 21:00:00 9.3 1.6 13.3 5.7 11.8 1.3 14.9 8.8 154 6 140 305 10.3 0 10.5 10.2 08/08/2005 21:10:00 9.2 1.5 13.7 6.5 11.6 1.1 14.5 8.4 154 6 147 305 10.3 0 10.5 10.2 08/08/2005 21:20:00 9.2 1.6 13.7 5.3 11.8 1.2 15.6 8.4 153 7 148 305 10.3 0 10.5 10.2 08/08/2005 21:30:00 9.9 1.7 14.9 5.7 11.6 1.3 14.5 8.4 151 7 146 305 10.3 0 10.5 10.2 08/08/2005 21:40:00 9.5 1.7 13.3 5.7 11 1.3 14.5 6.8 150 7 134 305 10.3 0 10.2 10.2 08/08/2005 21:50:00 9 1.6 13 4.2 10.1 1.2 13.7 6.8 150 8 145 305 10.2 0 10.2 10 08/08/2005 22:00:00 9.1 1.7 14.9 4.6 10.4 1.3 13.3 6.5 150 8 146 305 10 0 10.2 10 08/08/2005 22:10:00 7.8 1.5 12.2 4.6 9.3 1.2 13.3 4.9 156 10 145 305 10 0 10.2 10 08/08/2005 22:20:00 8.1 1.7 12.6 4.6 9.7 1.7 15.3 4.9 158 11 172 305 10 0 10.2 10 08/08/2005 22:30:00 8.6 1.7 13.3 4.9 9.9 1.7 15.3 5.7 161 12 174 305 10 0 10.2 10 08/08/2005 22:40:00 8.3 1.7 12.6 4.9 9.3 1.6 13 5.3 154 15 139 305 10 0 10.2 10 08/08/2005 22:50:00 9.4 1.7 14.9 5.7 10.8 1.9 16.1 5.7 160 13 146 305 10 0 10.2 10 08/08/2005 23:00:00 9.6 1.7 14.1 4.9 11.2 1.6 16.1 7.2 156 11 150 305 9.9 0 10 10 08/08/2005 23:10:00 9.6 1.7 13.7 5.7 11.9 1.4 16.1 8 158 10 144 305 9.9 0 10 10 08/08/2005 23:20:00 9.8 1.6 15.3 5.7 12.3 1.5 17.9 8.8 162 9 165 305 10 0 10 10 08/08/2005 23:30:00 9.8 1.7 15.3 6.1 11.8 1.6 16.8 7.2 161 9 174 305 10 0 10 10 08/08/2005 23:40:00 10.2 2 16.4 5.7 11.5 1.7 16.1 6.8 155 13 138 305 10 0 10.2 10 08/08/2005 23:50:00 12.1 2.5 17.9 6.1 12.3 2.1 17.9 8 143 12 138 305 9.9 0 10 10 08/09/2005 00:00:00 13.4 1.8 18.3 8.4 13.4 1.7 18.3 9.5 137 10 142 305 9.9 0 10.5 9.7 08/09/2005 00:10:00 13.7 1.7 17.9 9.5 13.6 1.5 17.6 10.3 137 8 143 305 9.9 0 10 9.7 08/09/2005 00:20:00 13.3 2.2 18.3 6.5 13.1 1.7 17.6 7.2 140 9 141 305 9.8 0 10 9.7 08/09/2005 00:30:00 9.9 2.4 16.1 5.3 10.1 2 16.1 5.7 142 13 134 305 9.7 0 10 9.7 08/09/2005 00:40:00 11.8 2.4 17.9 6.5 11.8 2.1 16.4 6.8 134 12 124 305 9.7 0 9.7 9.7 08/09/2005 00:50:00 15.3 1.5 19.9 10.7 14.9 1.6 19.9 10.3 128 6 127 305 9.7 0 9.7 9.7 08/09/2005 01:00:00 15.6 1.6 19.5 10.3 15.4 1.4 18.7 11.5 129 7 124 305 9.7 0 9.7 9.7 08/09/2005 01:10:00 15.9 1.5 20.6 11.8 15.6 1.5 18.7 11.8 128 6 123 305 9.7 0 9.7 9.5 08/09/2005 01:20:00 16.1 1.4 19.5 12.2 15.8 1.3 19.1 12.2 129 6 124 305 9.7 0 9.7 9.5 08/09/2005 01:30:00 14.7 1.7 19.5 10.3 14.5 1.7 19.5 10.3 133 8 133 305 9.7 0 9.7 9.7 08/09/2005 01:40:00 13 2 18.3 8 12.8 1.9 18.7 8 136 10 144 305 9.7 0 9.7 9.7 08/09/2005 01:50:00 11.8 1.7 16.4 7.2 11.6 1.7 15.3 5.7 131 10 131 305 9.7 0 10 9.7 08/09/2005 02:00:00 9.9 1.8 14.5 5.7 10 1.6 14.5 6.1 139 12 136 305 9.9 0 10 9.7 08/09/2005 02:10:00 10.4 1.7 14.5 5.7 10.4 1.5 13.7 5.7 140 8 137 305 9.9 0 10 10 08/09/2005 02:20:00 10.3 1.8 15.6 6.1 10.2 1.7 14.9 6.5 136 11 137 305 9.9 0 10 9.7 08/09/2005 02:30:00 12.1 1.6 14.9 7.6 11.9 1.5 15.3 7.2 129 9 137 305 9.9 0 10 9.7 08/09/2005 02:40:00 13.9 1.4 17.2 10.3 13.6 1.4 17.2 10.7 123 5 127 305 9.9 0 10 9.7 08/09/2005 02:50:00 14.3 1.1 16.8 10.7 14.2 1 17.2 10.7 128 5 129 305 9.7 0 10 9.7 08/09/2005 03:00:00 13.1 1.7 17.2 8.4 12.9 1.7 16.4 9.1 133 8 145 305 9.7 0 10 9.7 08/09/2005 03:10:00 13.4 1.6 17.9 8.4 13.2 1.5 17.2 9.9 137 8 147 305 9.7 0 9.7 9.7 08/09/2005 03:20:00 13 1.6 16.8 8.4 12.8 1.5 16.4 8.8 136 9 126 305 9.6 0 9.7 9.5 08/09/2005 03:30:00 11.2 1.5 16.4 6.8 11.2 1.5 15.6 7.2 134 9 144 305 9.5 0 9.7 9.5 08/09/2005 03:40:00 8.2 1.9 12.2 3.4 8.1 1.7 12.2 3.8 134 12 121 305 9.5 0 9.7 9.5 08/09/2005 03:50:00 7 1.6 12.2 3.4 7.2 1.5 13.3 4.2 141 15 145 305 9.6 0 9.7 9.5 08/09/2005 04:00:00 8.6 1.7 13.7 4.2 9.2 1.7 14.1 5.7 144 15 141 305 9.7 0 9.7 9.5 08/09/2005 04:10:00 9 2 14.1 4.6 9.9 1.8 16.1 6.1 150 15 138 305 9.7 0 10 9.7 08/09/2005 04:20:00 9.1 2 15.3 4.6 9.9 1.7 14.5 6.1 149 14 143 305 9.9 0 10 9.7 08/09/2005 04:30:00 9.2 1.8 14.9 4.9 9.8 1.7 14.5 6.1 145 13 131 305 9.9 0 10 10 08/09/2005 04:40:00 11.6 2.2 17.2 6.1 11.6 1.9 17.2 6.5 142 12 131 305 10 0 10 10 08/09/2005 04:50:00 12.2 1.7 16.4 6.5 12.2 1.4 16.1 8.4 140 9 139 305 10 0 10 10 08/09/2005 05:00:00 12.5 1.5 16.8 7.6 12.2 1.3 16.1 9.1 138 8 147 305 10 0 10.2 10 08/09/2005 05:10:00 9 2.1 13.7 3.8 9.4 1.5 13 5.7 144 11 130 305 10 0 10.2 10 08/09/2005 05:20:00 6.9 1.4 10.7 3 7.8 1.3 11.1 4.6 149 15 132 305 10 0 10.2 10 08/09/2005 05:30:00 8.2 2.1 13.7 4.2 8.5 1.8 13 3.8 142 17 142 305 10 0 10 10 08/09/2005 05:40:00 8.5 2.1 13.7 3 8.9 1.8 13.3 4.2 145 14 143 305 9.9 0 10 10 08/09/2005 05:50:00 5.8 2 10.7 2.3 6 1.8 11.1 1.9 144 18 147 305 9.9 0 10 10 08/09/2005 06:00:00 3.6 1.2 7.2 0.4 3.6 1.1 7.6 1.9 161 24 127 305 9.9 0 10 9.7 08/09/2005 06:10:00 4.9 2.1 10.3 0.7 4.7 2 9.1 0.4 132 32 134 305 9.9 0 10 9.7 08/09/2005 06:20:00 3.9 1.4 9.9 1.1 3.9 1.5 9.1 0.7 133 29 147 305 9.9 0 10 9.7 08/09/2005 06:30:00 4.1 1.5 8.4 1.1 4 1.5 8.4 1.1 134 23 123 305 9.9 0 10 9.7 08/09/2005 06:40:00 2.7 1.3 6.8 0.4 2.7 1.3 6.5 0.4 162 53 208 305 9.9 0 10 9.7 08/09/2005 06:50:00 5.8 3.2 13.7 0.4 5.6 3.1 13 0.4 127 29 138 305 9.9 0 10 9.7 08/09/2005 07:00:00 13.1 1.9 17.9 8.4 12.8 1.9 17.9 7.2 127 8 133 305 9.9 0 10 9.7 08/09/2005 07:10:00 14.5 1.7 18.7 8.8 14.1 1.7 19.1 9.1 127 7 131 305 9.9 0 10 9.7 08/09/2005 07:20:00 14 1.8 18.3 9.5 13.6 1.7 18.3 9.1 129 9 117 305 9.9 0 10 9.7 08/09/2005 07:30:00 15 2.1 19.9 8.4 14.8 2 19.1 8.4 130 10 123 305 9.9 0 10 9.7 08/09/2005 07:40:00 12.8 2.1 18.3 7.2 12.9 1.9 17.9 7.6 139 12 134 305 9.9 0 10 10 08/09/2005 07:50:00 14.4 2.3 21.4 6.5 14.7 2.2 20.6 8.8 139 11 141 305 10 0 10.2 10 08/09/2005 08:00:00 15.4 2.3 20.2 10.7 15.2 2.1 20.6 9.9 137 9 127 305 10 0 10.2 10 08/09/2005 08:10:00 17.1 2.1 21.8 11.1 16.7 1.9 22.1 11.5 136 8 144 305 10.1 0 10.2 10 08/09/2005 08:20:00 16.5 2.4 22.1 9.5 16.3 2.2 22.1 10.7 134 9 129 305 10.2 0 10.2 10.2 08/09/2005 08:30:00 17.8 1.9 22.6 11.8 17.6 1.9 22.9 11.5 133 8 132 305 10.2 0 10.2 10.2 08/09/2005 08:40:00 17.8 1.9 23.3 13.3 17.4 1.8 23.7 13.3 134 7 139 305 10.2 0 10.2 10.2 08/09/2005 08:50:00 15.7 1.7 19.9 11.8 15.6 1.6 19.9 11.5 134 8 155 305 10.2 0 10.2 10.2 08/09/2005 09:00:00 14.5 1.8 18.7 9.1 14.3 1.7 18.3 10.3 135 9 137 305 10.2 0 10.2 10.2 08/09/2005 09:10:00 13.6 1.6 19.1 9.1 13.3 1.5 19.1 9.1 135 8 130 305 10.2 0 10.2 10.2 08/09/2005 09:20:00 12.1 2.4 17.9 5.3 12.1 1.8 17.2 8.4 139 11 137 305 10.2 0 10.2 10.2 08/09/2005 09:30:00 13.1 2 19.1 5.7 13 1.8 18.3 8.4 137 9 131 305 10.2 0 10.2 10 08/09/2005 09:40:00 14.7 2.1 19.9 9.1 14.4 1.8 19.5 9.1 136 8 130 305 10.1 0 10.2 10 08/09/2005 09:50:00 12.6 2.5 19.1 6.8 12.8 2.1 18.3 7.6 138 9 138 305 10.2 0 10.2 10.2 08/09/2005 10:00:00 15.2 1.9 19.9 9.9 14.8 1.7 18.7 10.7 137 8 136 305 10.2 0 10.2 10.2 08/09/2005 10:10:00 14.5 1.9 19.5 9.1 14.3 1.7 19.1 9.5 136 9 141 305 10.2 0 10.2 10.2 08/09/2005 10:20:00 13.7 2 18.3 7.2 13.3 1.8 17.6 8.8 136 9 124 305 10.2 0 10.2 10.2 08/09/2005 10:30:00 12.1 2.1 17.2 7.2 12.2 2 17.6 7.2 137 9 136 305 10.2 0 10.2 10.2 08/09/2005 10:40:00 11.5 2.2 17.9 5.3 11.4 1.9 17.9 6.8 138 10 148 305 10.3 0 10.2 10.2 08/09/2005 10:50:00 10.1 2.1 14.5 5.3 10.7 1.7 15.6 6.5 141 11 143 305 10.3 0 10.5 10.2 08/09/2005 11:00:00 9.3 1.9 14.5 4.6 10.1 1.7 14.1 5.3 147 12 138 305 10.3 0 10.5 10.2 08/09/2005 11:10:00 8.8 1.8 13.7 4.9 9.9 1.7 14.9 4.9 153 13 135 305 10.3 0 10.5 10.2 08/09/2005 11:20:00 8.3 1.6 13.3 4.6 9.5 1.3 13.3 5.3 150 11 135 305 10.3 0 10.5 10.2 08/09/2005 11:30:00 8.5 1.7 13.3 4.9 9.3 1.5 13.7 6.1 146 13 134 305 10.4 0 10.5 10.2 08/09/2005 11:40:00 7.8 1.6 12.2 4.2 9.2 1.5 14.1 6.5 148 11 152 305 10.6 0 10.8 10.5 08/09/2005 11:50:00 8.4 1.6 13 4.9 9.1 1.6 14.9 4.2 146 13 146 305 10.6 0 10.8 10.5 08/09/2005 12:00:00 7.5 1.6 12.2 4.2 8.6 1.4 12.6 5.3 148 13 138 305 10.5 0 10.5 10.2 08/09/2005 12:10:00 7.8 1.7 11.8 4.2 8.6 1.4 12.2 5.3 145 14 137 305 10.6 0 10.8 10.5 08/09/2005 12:20:00 8.1 1.8 13 3.8 8.6 1.6 13 4.9 142 14 130 305 10.6 0 10.8 10.5 08/09/2005 12:30:00 8.3 1.7 13.3 4.9 8.9 1.3 12.6 5.7 141 12 139 305 10.6 0 10.8 10.5 08/09/2005 12:40:00 9.3 1.8 13.7 4.9 9.3 1.7 13.7 6.1 137 11 139 305 10.6 0 10.8 10.5 08/09/2005 12:50:00 10 1.8 14.9 5.7 9.9 1.5 14.5 5.7 136 12 140 305 10.6 0 10.8 10.5 08/09/2005 13:00:00 10 2.1 14.5 4.6 10.2 1.6 13.7 6.1 139 11 116 305 10.7 0 10.8 10.5 08/09/2005 13:10:00 10.2 2 16.8 5.7 10 1.7 16.1 6.1 138 10 138 305 10.8 0 10.8 10.5 08/09/2005 13:20:00 10.6 2 15.6 5.3 10.5 1.7 14.5 6.1 138 9 131 305 10.8 0 10.8 10.8 08/09/2005 13:30:00 9.7 1.7 14.5 4.9 9.7 1.3 14.5 6.8 138 11 136 305 10.8 0 10.8 10.8 08/09/2005 13:40:00 10.5 2 15.6 5.7 10.5 1.8 14.9 6.5 139 11 137 305 10.8 0 10.8 10.8 08/09/2005 13:50:00 11.1 2.2 16.4 5.3 11.1 1.8 16.4 6.5 138 10 131 305 10.8 0 10.8 10.8 08/09/2005 14:00:00 11.1 1.8 15.6 6.8 11.2 1.6 15.6 7.6 136 10 138 305 10.7 0 10.8 10.5 08/09/2005 14:10:00 11.4 2.1 16.4 5.7 11.2 1.8 16.4 7.2 133 9 136 305 10.8 0 10.8 10.5 08/09/2005 14:20:00 10.9 2 14.9 5.3 10.9 1.7 15.3 5.3 135 11 138 305 10.7 0 10.8 10.5 08/09/2005 14:30:00 9 1.9 13.7 4.2 9.3 1.7 13.7 5.7 138 12 128 305 10.7 0 10.8 10.5 08/09/2005 14:40:00 8.6 2.2 14.9 4.2 8.7 1.7 13.7 4.9 137 13 144 305 10.7 0 10.8 10.5 08/09/2005 14:50:00 10 2.2 14.9 4.6 10 1.8 14.5 6.1 137 14 139 305 10.6 0 10.8 10.5 08/09/2005 15:00:00 10.9 2 15.6 6.5 10.8 1.7 15.6 6.8 134 12 113 305 10.6 0 10.8 10.5 08/09/2005 15:10:00 10.1 2.2 16.1 5.7 10.2 1.9 16.4 5.7 134 13 138 305 10.6 0 10.8 10.5 08/09/2005 15:20:00 10.4 2.2 15.3 4.9 10.5 1.8 16.4 6.8 136 12 132 305 10.4 0.1 10.5 10.2 08/09/2005 15:30:00 11 1.7 15.3 6.5 11 1.4 14.5 6.5 136 9 138 305 10.4 0 10.5 10.2 08/09/2005 15:40:00 9.6 1.5 13.7 5.3 9.5 1.3 12.6 5.7 135 10 137 305 10.4 0 10.5 10.2 08/09/2005 15:50:00 8.7 2.1 14.1 3.8 8.9 1.6 13.3 4.9 137 14 133 305 10.4 0 10.5 10.2 08/09/2005 16:00:00 7.7 1.7 11.8 4.2 7.9 1.4 11.5 4.6 141 12 131 305 10.4 0 10.5 10.2 08/09/2005 16:10:00 7.7 1.7 11.8 4.2 8.3 1.3 12.6 5.3 142 13 142 305 10.5 0 10.5 10.5 08/09/2005 16:20:00 10.9 1.7 16.8 6.8 10.7 1.5 15.3 6.8 133 9 136 305 10.6 0 10.8 10.5 08/09/2005 16:30:00 10.8 2.2 15.6 5.7 10.9 1.8 15.3 6.5 136 10 137 305 10.8 0 10.8 10.5 08/09/2005 16:40:00 9.5 2.3 14.9 4.6 9.8 1.9 14.9 4.9 137 13 127 305 10.8 0 10.8 10.8 08/09/2005 16:50:00 10.4 2.1 16.1 5.7 10.6 1.8 14.5 6.1 137 12 143 305 10.7 0 10.8 10.5 08/09/2005 17:00:00 9.8 2.3 14.9 4.9 9.8 2.1 15.6 5.3 137 11 136 305 10.8 0 10.8 10.8 08/09/2005 17:10:00 7.1 1.7 11.8 3.4 7.9 1.5 11.5 4.2 147 15 127 305 10.8 0 10.8 10.8 08/09/2005 17:20:00 7.2 1.7 12.6 3.4 7.8 1.5 12.6 4.9 145 16 128 305 10.6 0 10.8 10.5 08/09/2005 17:30:00 9.9 2.2 14.5 4.9 10.1 1.7 14.1 4.9 137 12 141 305 10.5 0 10.8 10.5 08/09/2005 17:40:00 10.1 2 14.9 4.9 10.1 1.6 14.5 6.5 136 10 125 305 10.4 0 10.5 10.2 08/09/2005 17:50:00 9.4 2.3 14.5 4.2 9.8 1.7 14.9 5.3 139 11 136 305 10.5 0 10.8 10.5 08/09/2005 18:00:00 7.6 2.1 13.3 3.4 8.3 1.6 13.7 4.2 143 14 134 305 10.6 0 10.8 10.5 08/09/2005 18:10:00 6.9 1.6 11.8 3.4 7.4 1.4 12.6 4.2 144 15 129 305 10.5 0 10.5 10.5 08/09/2005 18:20:00 6.5 1.3 10.3 3.8 7.4 1.3 10.7 4.6 146 13 137 305 10.4 0 10.5 10.2 08/09/2005 18:30:00 7 1.5 11.5 3.8 7.6 1.3 11.5 4.6 142 12 140 305 10.3 0 10.5 10.2 08/09/2005 18:40:00 7.6 1.7 11.5 4.2 7.9 1.3 11.5 4.9 138 12 144 305 10.4 0 10.5 10.2 08/09/2005 18:50:00 8.3 1.6 12.2 4.6 8.7 1.2 12.6 5.3 139 10 124 305 10.4 0 10.5 10.2 08/09/2005 19:00:00 8.5 1.7 13 4.6 8.8 1.2 12.2 5.3 141 11 138 305 10.4 0 10.5 10.2 08/09/2005 19:10:00 9.6 2.1 14.9 4.6 9.9 1.6 14.1 5.3 138 10 142 305 10.3 0 10.5 10.2 08/09/2005 19:20:00 10.3 1.8 14.5 5.3 10.5 1.4 14.5 6.8 137 11 138 305 10.3 0 10.5 10.2 08/09/2005 19:30:00 10.7 2 15.6 6.1 11 1.5 14.5 6.8 137 10 139 305 10.3 0 10.2 10.2 08/09/2005 19:40:00 9.7 1.7 15.3 5.3 10.3 1.3 13.3 7.2 142 9 122 305 10.3 0 10.2 10.2 08/09/2005 19:50:00 9.6 1.8 14.9 4.9 10.3 1.3 13.7 7.2 144 10 133 305 10.3 0 10.5 10.2 08/09/2005 20:00:00 10.1 2 15.3 6.5 11.7 1.3 15.3 8.4 147 9 138 305 10.3 0 10.5 10.2 08/09/2005 20:10:00 9.3 1.7 14.9 5.3 11.1 1.3 14.9 8 148 8 135 305 10.3 0 10.5 10.2 08/09/2005 20:20:00 9.2 1.8 15.6 4.9 11 1.3 15.6 7.6 149 6 162 305 10.3 0 10.5 10.2 08/09/2005 20:30:00 9.6 1.7 14.1 5.7 10.4 1.4 13.7 6.8 144 9 138 305 10.3 0 10.2 10.2 08/09/2005 20:40:00 10.7 2.1 16.1 5.7 10.8 1.6 15.6 6.5 138 9 138 305 10.3 0 10.2 10.2 08/09/2005 20:50:00 11 1.8 15.6 5.3 10.8 1.6 15.6 6.8 137 9 133 305 10.3 0 10.5 10.2 08/09/2005 21:00:00 11.5 1.7 15.6 8 11.2 1.6 15.6 6.8 136 8 142 305 10.3 0 10.2 10.2 08/09/2005 21:10:00 12.2 1.6 15.6 6.8 12 1.4 15.3 8 136 8 133 305 10.2 0 10.2 10.2 08/09/2005 21:20:00 12 1.7 16.1 6.8 11.5 1.5 15.3 7.6 136 8 139 305 10.2 0 10.2 10.2 08/09/2005 21:30:00 12.4 1.3 15.6 7.2 12 1.2 15.3 8 136 7 141 305 10.1 0 10.2 10 08/09/2005 21:40:00 12.4 1.7 16.1 7.2 12 1.4 15.6 8 137 7 140 305 10 0 10.2 10 08/09/2005 21:50:00 12.1 1.3 15.3 8.8 11.6 1.2 14.5 8 137 6 137 305 10 0 10.2 10 08/09/2005 22:00:00 12.5 1.2 15.6 8.8 12.1 1.1 14.5 9.1 137 6 150 305 9.9 0 10 10 08/09/2005 22:10:00 11.6 1.5 14.5 7.6 11.2 1.3 14.1 8 136 7 146 305 9.9 0 10 10 08/09/2005 22:20:00 10.9 1.5 15.3 6.1 10.8 1.1 14.5 7.2 138 9 140 305 9.9 0 10 9.7 08/09/2005 22:30:00 9.1 2 13.7 4.9 9 1.7 13.3 5.7 140 11 141 305 9.9 0 10 9.7 08/09/2005 22:40:00 10 1.9 13.3 5.3 10.1 1.5 13.7 6.1 140 9 139 305 9.9 0 10 9.7 08/09/2005 22:50:00 9.1 2 13.7 4.6 9.2 1.6 13.3 6.1 141 9 136 305 9.9 0 10 9.7 08/09/2005 23:00:00 7.3 1.5 11.1 4.2 8.1 1.3 13.7 5.3 148 11 130 305 9.9 0 10 9.7 08/09/2005 23:10:00 6.9 1.3 10.3 4.2 7.6 1 10.3 5.7 146 9 142 305 9.9 0 10 10 08/09/2005 23:20:00 6.4 1.2 9.9 3.8 7.5 1 10.3 4.9 149 9 148 305 9.9 0 10 10 08/09/2005 23:30:00 6.4 1.2 9.1 3.8 7.4 1.1 10.3 4.9 149 9 143 305 9.9 0 10 10 08/09/2005 23:40:00 5.7 1.1 8.8 3.4 6.9 1 9.5 4.6 151 9 143 305 9.9 0 10 9.7 08/09/2005 23:50:00 5.7 1 8.4 3.4 8.1 0.8 9.5 5.3 156 6 152 305 9.9 0 10 9.7 08/10/2005 00:00:00 5.5 0.9 7.6 3 8 0.6 9.5 6.1 153 4 150 305 9.9 0 10.2 9.7 08/10/2005 00:10:00 5.7 1 8.8 3.4 7.6 0.6 8.8 5.7 151 4 147 305 9.9 0 10 9.7 08/10/2005 00:20:00 5.6 1.1 8.8 3 7 0.8 8.8 4.6 150 6 138 305 9.9 0 10 9.7 08/10/2005 00:30:00 6.3 1.3 9.1 3.4 6.6 1 9.9 4.2 142 10 141 305 9.9 0 10 9.7 08/10/2005 00:40:00 6.4 1.7 10.3 2.3 6.9 1.2 10.3 4.6 143 11 139 305 9.8 0 10 9.7 08/10/2005 00:50:00 6.3 1.7 9.9 2.6 7.1 1.2 9.9 4.6 148 11 138 305 9.9 0 10 9.7 08/10/2005 01:00:00 7.5 1.6 11.5 4.2 7.8 1.3 11.5 4.9 142 9 136 305 9.7 0 10 9.7 08/10/2005 01:10:00 8 1.4 10.7 3.8 8 1 10.7 5.7 141 8 143 305 9.7 0 9.7 9.7 08/10/2005 01:20:00 6.2 1.2 9.5 3 6.4 0.9 9.1 4.6 142 9 133 305 9.7 0 9.7 9.7 08/10/2005 01:30:00 7.2 0.9 9.5 4.9 7 0.8 8.8 4.6 137 7 141 305 9.7 0 9.7 9.5 08/10/2005 01:40:00 6.9 1 9.5 4.2 6.8 0.8 9.1 4.2 135 7 133 305 9.7 0 9.7 9.5 08/10/2005 01:50:00 8.1 0.7 9.5 6.1 7.9 0.7 9.1 5.3 129 5 129 305 9.6 0 9.7 9.5 08/10/2005 02:00:00 7.6 0.7 9.1 4.9 7.5 0.7 9.1 5.7 130 6 131 305 9.6 0 9.7 9.5 08/10/2005 02:10:00 7.1 0.7 9.1 5.3 6.9 0.6 8.8 5.3 133 7 144 305 9.7 0 9.7 9.5 08/10/2005 02:20:00 7 0.9 9.1 3.8 6.8 0.7 8.8 4.6 137 7 135 305 9.7 0 9.7 9.5 08/10/2005 02:30:00 8.3 1.1 10.7 4.9 8.2 1 10.7 4.9 131 7 132 305 9.6 0 9.7 9.5 08/10/2005 02:40:00 7.4 1 10.3 4.9 7.5 1 10.3 5.7 138 8 132 305 9.6 0 9.7 9.5 08/10/2005 02:50:00 8 1 11.5 5.3 7.8 0.9 10.3 5.3 138 7 144 305 9.5 0 9.7 9.5 08/10/2005 03:00:00 6.6 1 9.1 4.6 6.5 0.8 8.8 4.2 135 8 136 305 9.5 0 9.7 9.5 08/10/2005 03:10:00 7.1 1.1 9.5 3.8 7.1 1 9.5 4.9 131 8 119 305 9.5 0 9.5 9.2 08/10/2005 03:20:00 8.5 0.9 10.3 6.1 8.4 0.8 10.3 6.1 129 6 127 305 9.3 0 9.5 9.2 08/10/2005 03:30:00 8.5 0.8 10.3 6.5 8.3 0.8 9.9 6.5 128 5 132 305 9.3 0 9.5 9.2 08/10/2005 03:40:00 7.7 0.8 9.9 6.1 7.6 0.7 9.9 6.1 128 5 124 305 9.3 0 9.5 9.2 08/10/2005 03:50:00 8.1 0.6 9.5 6.5 7.9 0.6 9.9 6.1 128 4 130 305 9.2 0 9.5 9.2 08/10/2005 04:00:00 8.7 0.8 10.3 6.8 8.6 0.8 9.9 6.5 129 4 129 305 9.2 0 9.5 9.2 08/10/2005 04:10:00 9.4 0.7 11.1 7.2 9.3 0.7 10.7 7.2 129 5 138 305 9.2 0 9.5 9.2 08/10/2005 04:20:00 8.6 1 10.7 5.3 8.4 0.9 10.3 6.1 135 6 133 305 9.2 0 9.5 9.2 08/10/2005 04:30:00 9 0.8 11.1 6.8 8.7 0.8 10.7 6.8 135 6 136 305 9.2 0 9.5 9.2 08/10/2005 04:40:00 8 0.8 9.5 5.3 7.8 0.6 9.1 6.1 137 5 144 305 9.2 0 9.5 9.2 08/10/2005 04:50:00 5.6 1.3 8.4 2.6 6.1 0.8 8 4.2 145 9 144 305 9.2 0 9.5 9.2 08/10/2005 05:00:00 6.9 0.8 9.1 4.2 6.8 0.6 8.4 4.9 136 8 136 305 9.2 0 9.5 9.2 08/10/2005 05:10:00 7.8 0.9 9.9 5.7 7.6 0.9 9.5 5.7 131 5 136 305 9.2 0 9.2 9.2 08/10/2005 05:20:00 7.8 0.8 9.5 5.3 7.5 0.7 9.5 5.7 137 5 138 305 9.2 0 9.2 9.2 08/10/2005 05:30:00 5 1.2 8.4 2.6 5.5 0.9 8.4 3 149 11 144 305 9.2 0 9.5 9.2 08/10/2005 05:40:00 4.8 1.1 7.6 2.3 5.4 0.8 7.2 3 150 12 149 305 9.2 0 9.5 9.2 08/10/2005 05:50:00 6.2 1.6 9.9 2.6 6.5 1.2 9.5 3.8 142 10 139 305 9.2 0 9.5 9.2 08/10/2005 06:00:00 6.8 1.4 9.9 3.4 6.8 1 9.5 4.2 144 8 144 305 9.2 0 9.5 9.2 08/10/2005 06:10:00 5.6 1.3 8.8 3 6.3 1.1 9.9 3.8 146 10 140 305 9.3 0 9.5 9.2 08/10/2005 06:20:00 5.8 1.3 8.8 2.6 6.2 1 8 3.4 146 11 147 305 9.3 0 9.5 9.2 08/10/2005 06:30:00 5.3 1.1 7.6 3 6.2 0.8 8.8 4.2 149 10 139 305 9.3 0 9.5 9.2 08/10/2005 06:40:00 5.4 1.3 8.8 3 6.1 1 8.8 3.8 148 10 142 305 9.3 0 9.5 9.2 08/10/2005 06:50:00 4.8 0.9 6.8 2.6 5.9 0.8 8 3.8 156 9 165 305 9.3 0 9.5 9.2 08/10/2005 07:00:00 5.3 1.1 8.4 3 6.7 1.1 9.1 3.8 156 8 142 305 9.3 0 9.5 9.2 08/10/2005 07:10:00 5.3 1.2 8 3 6.5 0.8 8.8 4.2 150 9 152 305 9.3 0 9.5 9.2 08/10/2005 07:20:00 5 1 8.8 3 6.9 0.8 9.5 4.9 155 7 141 305 9.3 0 9.5 9.2 08/10/2005 07:30:00 6.6 1.1 9.1 4.2 7.1 0.9 9.5 4.9 145 8 145 305 9.3 0 9.5 9.2 08/10/2005 07:40:00 6.2 1.3 8.8 3 6.6 0.9 8.8 4.2 146 8 135 305 9.3 0 9.5 9.2 08/10/2005 07:50:00 4.5 1.1 7.6 2.3 5.3 1 8 2.6 153 10 158 305 9.3 0 9.5 9.2 08/10/2005 08:00:00 4.8 1.1 8 2.3 5.8 0.8 7.6 3.8 151 9 136 305 9.3 0 9.5 9.2 08/10/2005 08:10:00 5.8 1.3 8.4 2.3 6 1 8.4 3.4 143 9 140 305 9.3 0 9.5 9.2 08/10/2005 08:20:00 7.3 0.8 9.1 4.9 7.2 0.6 9.1 5.3 140 6 136 305 9.4 0 9.5 9.2 08/10/2005 08:30:00 7.1 1.1 9.5 3.8 7.2 0.8 9.5 5.3 142 8 139 305 9.4 0 9.5 9.2 08/10/2005 08:40:00 6.6 1.2 9.5 3 7 0.8 9.5 4.9 145 8 134 305 9.3 0 9.5 9.2 08/10/2005 08:50:00 6.5 1.2 9.1 3.4 6.9 1 9.5 4.2 146 9 142 305 9.4 0 9.5 9.2 08/10/2005 09:00:00 5.9 1.1 9.9 3 6.8 0.9 10.3 4.9 150 6 143 305 9.5 0 9.7 9.5 08/10/2005 09:10:00 5.5 1 7.6 3.8 7.3 0.6 8.8 5.7 153 5 149 305 9.5 0 9.7 9.5 08/10/2005 09:20:00 5.3 1 8 3.4 6.8 0.7 8.4 4.6 153 5 150 305 9.5 0 9.7 9.5 08/10/2005 09:30:00 5.9 1 8.4 3.4 7.2 0.7 8.8 5.3 151 6 144 305 9.5 0 9.7 9.5 08/10/2005 09:40:00 5.9 1 8.4 3.4 6.5 0.6 8.4 4.6 148 6 142 305 9.5 0 9.7 9.5 08/10/2005 09:50:00 4.9 0.8 7.2 3 6.1 0.8 8.4 4.6 152 8 139 305 9.6 0 9.7 9.5 08/10/2005 10:00:00 5.2 1 8.4 3 7.1 0.8 9.1 4.9 157 6 151 305 9.8 0 10 9.7 08/10/2005 10:10:00 5 0.7 7.2 3.4 7.3 0.8 9.1 4.6 159 5 159 305 9.9 0 10.2 9.7 08/10/2005 10:20:00 5.1 0.9 8 3.4 7.3 0.8 9.1 5.3 156 5 150 305 10.2 0 10.2 10 08/10/2005 10:30:00 5.2 0.8 8 3 7.6 0.7 9.1 5.7 156 5 149 305 10.3 0 10.5 10.2 08/10/2005 10:40:00 5.5 0.9 8.8 3.8 7.8 0.8 9.5 5.3 157 6 161 305 10.3 0 10.5 10.2 08/10/2005 10:50:00 5.3 1 8 3 6.8 0.8 8.8 4.6 160 8 165 305 10.4 0.1 10.8 10.2 08/10/2005 11:00:00 5.2 1 8 3 6.7 1 8.8 4.2 163 7 176 305 10.6 0 10.8 10.5 08/10/2005 11:10:00 5.3 0.8 8 3.4 7.5 0.8 9.5 5.7 157 6 145 305 10.7 0 10.8 10.5 08/10/2005 11:20:00 5.5 1 8.4 3 7.1 0.7 9.1 5.3 161 7 170 305 10.6 0 10.8 10.5 08/10/2005 11:30:00 5.7 1 8.4 3.4 7.2 0.8 9.1 5.3 163 6 167 305 10.6 0 10.8 10.5 08/10/2005 11:40:00 5.6 1.1 9.1 3.4 7.3 0.9 9.5 4.6 163 6 168 305 10.6 0 10.8 10.5 08/10/2005 11:50:00 6 1 8.4 3.4 7.2 0.7 8.8 5.3 166 6 172 305 10.7 0 10.8 10.5 08/10/2005 12:00:00 7.8 1.5 10.7 4.2 8.1 1 10.7 5.7 172 6 178 305 10.8 0 11 10.8 08/10/2005 12:10:00 9 0.7 10.7 6.5 8.9 0.8 10.7 6.1 174 5 181 305 11 0 11 10.8 08/10/2005 12:20:00 8.9 0.8 10.3 6.5 8.5 0.9 10.3 6.1 186 3 190 305 10.9 0 11 10.8 08/10/2005 12:30:00 10.1 0.6 11.8 8 9.6 0.7 11.1 7.6 186 3 184 305 10.8 0 11 10.8 08/10/2005 12:40:00 9.8 0.7 11.5 7.2 9.5 0.8 11.1 6.8 183 3 177 305 11 0 11.3 10.8 08/10/2005 12:50:00 8.9 0.9 10.3 6.5 8.4 1.2 10.7 5.3 188 6 176 305 11.2 0 11.3 11 08/10/2005 13:00:00 8.9 0.6 10.7 6.8 8.5 0.8 9.9 6.5 190 4 194 305 10.9 0 11 10.8 08/10/2005 13:10:00 8.6 0.6 10.3 7.2 8.1 0.7 9.9 5.7 190 5 184 305 10.9 0 11 10.8 08/10/2005 13:20:00 9.2 0.6 10.7 7.2 8.9 0.7 10.7 6.5 189 4 188 305 10.9 0 11 10.8 08/10/2005 13:30:00 8.8 0.6 10.7 6.1 8.3 0.8 9.9 5.7 193 5 196 305 10.9 0 11 10.8 08/10/2005 13:40:00 8.6 0.8 10.7 6.8 7.6 0.9 9.9 5.3 195 6 183 305 10.8 0 11 10.8 08/10/2005 13:50:00 8.9 0.8 10.7 6.1 8.1 1 10.3 5.3 196 6 200 305 10.6 0 10.8 10.5 08/10/2005 14:00:00 9 0.6 10.3 6.5 8.5 0.8 9.9 6.1 192 5 193 305 10.6 0 10.8 10.5 08/10/2005 14:10:00 8.5 0.6 9.9 6.5 8.1 0.7 9.9 6.1 188 4 192 305 10.7 0 10.8 10.5 08/10/2005 14:20:00 8 0.5 9.1 6.5 7.6 0.5 9.1 6.1 187 3 185 305 10.8 0 11 10.8 08/10/2005 14:30:00 7.9 1 9.9 4.9 7.2 1 9.5 4.9 198 5 192 305 10.8 0 10.8 10.5 08/10/2005 14:40:00 9.1 0.8 10.7 6.5 8.2 1 10.7 5.7 198 6 194 305 10.6 0 10.8 10.5 08/10/2005 14:50:00 8.5 0.8 9.9 6.1 7.9 0.9 9.5 4.9 193 6 189 305 10.8 0 11 10.8 08/10/2005 15:00:00 8.2 0.7 9.5 6.5 7.9 0.8 9.5 4.9 187 4 187 305 11 0 11.3 10.8 08/10/2005 15:10:00 7.7 0.7 9.5 5.3 7 1 8.8 4.2 193 6 197 305 11.2 0 11.6 11 08/10/2005 15:20:00 7.7 0.7 9.5 5.3 6.8 0.9 8.4 3.8 197 7 203 305 11.2 0.1 11.6 11 08/10/2005 15:30:00 7 1.1 9.9 4.2 7.7 1.3 10.7 4.2 172 11 167 305 11 0.1 11.3 10.8 08/10/2005 15:40:00 8.2 1.2 10.3 4.2 9.2 0.9 11.1 6.8 168 5 169 305 11.9 0.4 12.4 11.3 08/10/2005 15:50:00 7.9 1 9.5 4.9 7.6 1.1 9.9 4.6 176 5 174 305 12.6 0 12.9 12.4 08/10/2005 16:00:00 8.7 0.7 10.3 6.1 8.1 0.9 9.9 4.9 189 6 192 305 12.5 0 12.9 12.1 08/10/2005 16:10:00 7.8 0.7 9.5 5.3 7 0.8 9.1 4.9 195 6 186 305 12.1 0 12.4 11.8 08/10/2005 16:20:00 7.5 0.8 9.1 4.6 6.8 0.9 8.4 4.6 195 7 199 305 11.8 0 11.8 11.6 08/10/2005 16:30:00 7.5 0.8 9.9 4.9 7 0.9 8.8 4.2 193 6 194 305 11.4 0 11.6 11.3 08/10/2005 16:40:00 7.9 0.8 9.9 5.7 7 1 9.5 4.9 193 8 198 305 11.4 0 11.6 11.3 08/10/2005 16:50:00 7.5 1 9.5 4.6 8.6 0.7 10.3 6.8 166 4 172 305 12 0.1 12.4 11.3 08/10/2005 17:00:00 8.2 0.9 10.3 5.7 7.7 0.9 10.3 4.6 190 9 198 305 11.6 0.3 12.4 11.3 08/10/2005 17:10:00 8.9 0.9 10.7 6.1 8 1 10.3 4.9 194 6 185 305 11.1 0 11.3 11 08/10/2005 17:20:00 9.3 1 11.1 6.1 8.7 1.1 11.1 5.7 191 6 188 305 11.2 0 11.6 11 08/10/2005 17:30:00 8.2 1 10.7 5.7 7.4 1.3 10.7 3.8 193 6 184 305 11.6 0 11.8 11.3 08/10/2005 17:40:00 8.3 0.9 10.3 4.9 7.3 1 10.3 4.9 196 7 194 305 11.3 0.2 11.8 11 08/10/2005 17:50:00 8 0.7 9.9 5.7 7.6 0.9 9.1 4.9 193 6 200 305 10.8 0 11 10.5 08/10/2005 18:00:00 8.3 0.9 10.7 5.7 7.6 1 10.3 4.9 195 6 183 305 10.6 0 10.8 10.5 08/10/2005 18:10:00 9.2 0.9 11.5 6.1 8.5 1 11.1 5.3 195 6 200 305 10.5 0.1 10.8 10.2 08/10/2005 18:20:00 9.2 0.8 10.7 6.1 8.3 0.9 10.3 6.1 195 6 192 305 10.4 0 10.5 10.2 08/10/2005 18:30:00 8.6 0.9 10.7 5.7 7.8 1 9.9 4.9 194 5 198 305 10.6 0 10.8 10.5 08/10/2005 18:40:00 9.1 0.8 11.5 6.8 8.7 0.9 11.1 6.1 188 5 177 305 10.8 0 11 10.8 08/10/2005 18:50:00 10.1 0.7 11.8 7.6 9.8 0.8 11.5 6.5 188 5 188 305 11 0 11.3 10.8 08/10/2005 19:00:00 9.7 0.7 11.5 8 9.3 0.7 11.1 7.2 189 3 189 305 10.8 0 11 10.8 08/10/2005 19:10:00 8 0.7 9.5 6.1 7.5 0.8 9.5 5.3 189 5 184 305 10.8 0 11 10.8 08/10/2005 19:20:00 8.8 0.8 10.7 6.1 8.3 0.9 10.3 5.3 190 5 190 305 10.6 0 10.8 10.5 08/10/2005 19:30:00 8.9 0.7 11.1 5.7 8.5 0.8 10.7 6.1 190 4 189 305 10.5 0 10.8 10.5 08/10/2005 19:40:00 9.4 0.6 10.7 7.2 9 0.7 11.1 6.5 190 4 188 305 10.4 0 10.5 10.2 08/10/2005 19:50:00 9.3 0.6 10.3 7.6 8.9 0.6 10.3 6.8 189 3 189 305 10.3 0 10.5 10.2 08/10/2005 20:00:00 8.6 0.6 10.3 6.5 8.3 0.7 9.9 5.7 186 3 186 305 10.4 0 10.5 10.2 08/10/2005 20:10:00 8.7 0.6 9.9 7.2 8.5 0.6 9.9 6.8 187 4 186 305 10.4 0 10.5 10.2 08/10/2005 20:20:00 9 0.6 10.3 7.2 8.7 0.6 10.3 6.8 191 4 186 305 10.3 0 10.5 10.2 08/10/2005 20:30:00 8.9 0.7 10.7 7.2 8.5 0.7 10.3 6.1 190 4 193 305 10.1 0 10.2 10 08/10/2005 20:40:00 8.6 0.6 9.9 6.8 8.3 0.7 9.5 6.1 187 3 188 305 10 0 10.2 10 08/10/2005 20:50:00 7.9 0.6 9.9 6.5 7.6 0.8 9.1 5.7 184 4 183 305 10 0 10.2 10 08/10/2005 21:00:00 7.3 0.6 8.8 5.3 7 0.7 8.8 4.9 183 4 183 305 10.3 0 10.5 10.2 08/10/2005 21:10:00 7.9 0.6 9.5 6.5 7.5 0.8 9.5 4.9 181 5 179 305 10.4 0 10.5 10.2 08/10/2005 21:20:00 6.8 0.9 8.8 4.2 6.7 0.7 8.8 4.6 176 6 177 305 10.3 0 10.5 10.2 08/10/2005 21:30:00 6.3 0.5 7.6 4.6 6.6 0.5 7.6 4.9 171 4 171 305 10.3 0 10.5 10.2 08/10/2005 21:40:00 7 0.8 9.1 4.9 6.8 0.9 9.1 4.2 177 5 181 305 10.4 0 10.5 10.2 08/10/2005 21:50:00 6.6 0.6 8.8 4.9 6.6 0.6 8.4 4.6 174 4 174 305 10.3 0 10.5 10.2 08/10/2005 22:00:00 7.6 0.9 9.9 5.3 7.3 1 9.1 4.9 178 5 177 305 10.4 0 10.8 10.2 08/10/2005 22:10:00 8.5 0.7 9.9 6.1 8.1 0.8 9.9 5.7 181 5 188 305 10.6 0 10.8 10.5 08/10/2005 22:20:00 8 0.6 9.1 6.1 7.7 0.8 9.1 4.9 183 5 186 305 10.4 0 10.5 10.2 08/10/2005 22:30:00 7.8 0.7 10.3 5.7 7.5 0.8 9.5 4.9 182 5 190 305 10.3 0 10.5 10.2 08/10/2005 22:40:00 7.6 0.7 9.5 5.3 7.4 0.8 9.1 5.3 178 5 183 305 10.3 0 10.5 10.2 08/10/2005 22:50:00 6.8 0.6 8 5.3 6.8 0.5 8 5.3 175 4 177 305 10.3 0 10.5 10.2 08/10/2005 23:00:00 6.6 0.9 9.1 4.6 6.5 0.8 8.8 4.6 177 6 189 305 10.4 0 10.5 10.2 08/10/2005 23:10:00 6.4 0.6 8 4.9 6.4 0.6 8 4.6 176 5 183 305 10.4 0 10.5 10.2 08/10/2005 23:20:00 6.9 1 9.1 4.2 6.9 0.8 8.8 5.3 177 6 179 305 10.4 0 10.8 10.2 08/10/2005 23:30:00 7.8 0.5 9.1 6.5 7.5 0.6 9.1 5.7 180 4 174 305 10.6 0 10.8 10.5 08/10/2005 23:40:00 7 0.8 8.8 4.2 6.8 0.8 8.8 3.8 178 5 183 305 10.6 0 10.8 10.5 08/10/2005 23:50:00 6.9 0.8 8.8 4.6 6.6 0.9 8.8 4.2 182 5 186 305 10.6 0 10.8 10.5 08/11/2005 00:00:00 7 0.6 8.8 5.3 6.8 0.7 8.8 4.9 180 4 182 305 10.5 0 11 10.5 08/11/2005 00:10:00 6.1 0.6 7.6 4.2 6.1 0.6 7.6 4.6 175 5 172 305 10.5 0 10.5 10.5 08/11/2005 00:20:00 5.9 0.5 7.2 4.6 6 0.5 6.8 4.2 172 4 165 305 10.5 0 10.5 10.5 08/11/2005 00:30:00 5.5 0.7 7.2 3.4 5.9 0.6 7.2 4.2 171 4 166 305 10.6 0 10.8 10.5 08/11/2005 00:40:00 4.8 1 6.5 2.3 5.5 0.6 6.8 3.8 168 5 166 305 10.6 0 10.8 10.5 08/11/2005 00:50:00 4.9 0.7 6.1 2.6 5.3 0.5 6.8 3.8 171 5 176 305 10.6 0 10.8 10.5 08/11/2005 01:00:00 5.3 0.8 7.2 3.4 5.3 0.7 7.2 3.8 176 6 186 305 10.5 0 10.5 10.5 08/11/2005 01:10:00 4.4 0.9 6.5 2.6 5.3 0.6 7.6 3 167 7 174 305 10.4 0 10.5 10.2 08/11/2005 01:20:00 4.9 1.3 8.4 1.9 5.5 0.7 8 3.8 152 11 147 305 10.4 0 10.5 10.2 08/11/2005 01:30:00 6.4 1.5 9.1 3 6.9 0.8 8.4 3.8 147 9 145 305 10 0 10.2 9.7 08/11/2005 01:40:00 5.1 0.7 7.6 3.8 7.8 0.7 9.1 5.3 159 4 150 305 9.6 0 10 9.5 08/11/2005 01:50:00 5.3 1 8 3.4 6.6 1 8.8 4.2 154 7 141 305 9.3 0 9.5 9.2 08/11/2005 02:00:00 6.7 1.2 9.1 3.4 7.5 0.8 9.1 5.3 148 8 140 305 9.2 0 9.5 9.2 08/11/2005 02:10:00 7.4 1.1 10.3 3.8 7.5 0.9 9.5 5.7 144 6 140 305 9.2 0 9.2 9.2 08/11/2005 02:20:00 9.1 1 11.1 5.7 8.6 0.9 10.3 5.7 141 4 143 305 9.1 0 9.2 9.2 08/11/2005 02:30:00 8.7 0.9 10.7 6.1 8.2 0.9 10.3 5.7 139 4 137 305 9.1 0 9.2 8.9 08/11/2005 02:40:00 8.8 0.8 10.7 5.7 8.3 0.8 10.3 6.1 140 4 140 305 8.9 0 9.2 8.9 08/11/2005 02:50:00 8.1 0.8 9.9 6.1 7.9 0.7 9.5 6.1 135 6 140 305 8.9 0 8.9 8.9 08/11/2005 03:00:00 7.9 1 10.7 4.9 7.6 0.9 9.9 5.3 139 6 148 305 8.8 0 8.9 8.7 08/11/2005 03:10:00 8.7 0.9 10.3 5.7 8.3 0.8 10.3 6.1 139 5 143 305 8.8 0 8.9 8.7 08/11/2005 03:20:00 8.5 1 10.7 5.3 8.1 0.9 9.9 5.3 140 5 136 305 8.8 0 8.9 8.7 08/11/2005 03:30:00 7.3 0.8 9.9 5.3 7 0.8 9.1 4.9 136 7 141 305 8.8 0 8.9 8.7 08/11/2005 03:40:00 7.6 1.1 9.9 4.9 7.3 1 9.9 4.9 140 7 146 305 8.8 0 8.9 8.7 08/11/2005 03:50:00 7.2 0.8 9.5 4.6 7 0.7 8.4 4.9 140 6 141 305 8.8 0 8.9 8.7 08/11/2005 04:00:00 7.5 0.8 9.5 5.3 7.2 0.8 8.8 4.9 138 6 139 305 8.8 0 8.9 8.7 08/11/2005 04:10:00 6.9 0.9 9.1 4.6 6.7 0.8 8.4 4.6 139 6 142 305 8.8 0 8.9 8.7 08/11/2005 04:20:00 6.9 1 9.1 4.2 6.8 0.7 8.8 4.9 140 8 145 305 8.9 0 9.2 8.9 08/11/2005 04:30:00 6.7 0.9 8.8 4.2 6.6 0.8 8.4 4.6 140 7 140 305 8.9 0 9.2 8.9 08/11/2005 04:40:00 6.5 1.2 9.1 3.4 6.5 0.8 8.4 4.2 144 7 141 305 9 0 9.2 8.9 08/11/2005 04:50:00 5.1 1 7.6 3 5.8 0.8 8 3.8 150 10 151 305 9.1 0 9.2 8.9 08/11/2005 05:00:00 5.5 1.4 9.1 3 6.1 1 8.8 3.8 148 11 140 305 9.1 0 9.2 8.9 08/11/2005 05:10:00 5.9 1 9.5 3.4 7.2 1 10.3 4.9 155 9 139 305 9.1 0 9.2 8.9 08/11/2005 05:20:00 5.6 1 8.4 3.4 7 0.8 9.1 4.6 157 9 151 305 9.2 0 9.2 9.2 08/11/2005 05:30:00 5.3 1 8.8 3.4 7 0.8 8.8 4.6 157 8 145 305 9.2 0 9.2 9.2 08/11/2005 05:40:00 5.4 1 8.4 3.4 6.8 0.8 8.8 4.9 156 8 144 305 9.2 0 9.2 9.2 08/11/2005 05:50:00 5.9 1.1 8.8 3 6.9 0.8 9.1 4.9 151 7 139 305 9.2 0 9.2 9.2 08/11/2005 06:00:00 6 1.1 9.5 3.4 6.5 0.8 9.1 4.6 148 7 138 305 9.1 0 9.2 9.2 08/11/2005 06:10:00 6 1.1 8.4 3.8 6.8 0.8 8.4 4.9 150 7 143 305 9.1 0 9.2 8.9 08/11/2005 06:20:00 5.5 1 8 3 5.9 0.9 8.4 4.2 147 7 153 305 9.1 0 9.2 9.2 08/11/2005 06:30:00 6.8 0.7 8 4.2 6.5 0.6 7.6 4.9 142 5 146 305 9.1 0 9.2 8.9 08/11/2005 06:40:00 6.8 0.7 8.8 4.9 6.4 0.6 8 4.6 141 5 148 305 9.1 0 9.2 9.2 08/11/2005 06:50:00 6.7 0.9 8.8 3.8 6.5 0.8 8.4 4.6 143 6 137 305 9.1 0 9.2 8.9 08/11/2005 07:00:00 7 0.9 9.1 4.2 6.8 0.6 8 4.9 145 5 144 305 9.1 0 9.2 8.9 08/11/2005 07:10:00 7.4 0.9 9.5 4.9 7.2 0.8 8.8 4.9 142 6 140 305 9.1 0 9.2 8.9 08/11/2005 07:20:00 7.3 0.8 9.5 5.3 7.2 0.8 9.1 4.9 136 6 138 305 9.1 0 9.2 8.9 08/11/2005 07:30:00 8.7 0.9 11.1 6.5 8.5 0.9 10.7 6.1 134 6 147 305 9.1 0 9.2 8.9 08/11/2005 07:40:00 8.7 0.9 10.7 6.1 8.5 0.8 10.7 6.1 138 7 140 305 9.1 0 9.2 8.9 08/11/2005 07:50:00 8.7 0.8 10.7 6.5 8.4 0.8 10.3 6.5 138 6 138 305 9.1 0 9.2 8.9 08/11/2005 08:00:00 8.6 1.2 11.1 5.3 8.5 0.9 11.5 6.5 141 8 147 305 9.1 0 9.2 8.9 08/11/2005 08:10:00 8.8 0.9 10.7 5.7 8.6 0.9 10.7 5.3 137 6 140 305 9.2 0 9.2 9.2 08/11/2005 08:20:00 8.9 0.8 10.7 6.8 8.7 0.8 10.7 6.5 137 6 142 305 9.2 0 9.2 8.9 08/11/2005 08:30:00 8.3 0.7 10.3 6.5 8.1 0.7 9.9 6.1 136 5 137 305 9.2 0 9.2 9.2 08/11/2005 08:40:00 8.3 0.8 9.9 5.7 8.2 0.9 9.9 5.3 134 5 137 305 9.2 0 9.2 9.2 08/11/2005 08:50:00 8.6 0.9 10.7 5.7 8.5 0.8 9.9 6.1 135 6 127 305 9.2 0 9.2 9.2 08/11/2005 09:00:00 9 1 10.7 5.7 8.8 1 11.1 6.5 134 5 131 305 9.3 0 9.5 9.2 08/11/2005 09:10:00 8.6 0.7 10.7 6.5 8.4 0.7 9.9 6.1 136 6 130 305 9.4 0 9.7 9.2 08/11/2005 09:20:00 8.4 0.7 9.5 6.5 8.3 0.7 9.5 5.7 136 6 136 305 9.5 0 9.7 9.5 08/11/2005 09:30:00 9 0.9 10.7 6.5 8.7 0.8 10.3 6.1 140 5 145 305 9.7 0 9.7 9.5 08/11/2005 09:40:00 8.5 0.8 9.9 6.5 8.3 0.8 9.9 6.1 135 6 138 305 9.7 0 10 9.7 08/11/2005 09:50:00 8.6 0.8 10.7 6.1 8.4 0.8 10.3 6.1 133 5 130 305 9.9 0 10 9.7 08/11/2005 10:00:00 9.8 0.7 11.5 7.6 9.7 0.7 11.5 7.6 132 5 136 305 9.9 0 10 9.7 08/11/2005 10:10:00 9.3 0.9 11.1 6.8 9.2 0.8 11.1 6.8 132 5 137 305 10 0 10.2 10 08/11/2005 10:20:00 9 1 11.5 6.5 8.8 0.9 10.7 6.5 131 6 138 305 10.2 0 10.2 10 08/11/2005 10:30:00 8.4 1 11.5 6.1 8.2 0.8 10.3 6.1 135 8 145 305 10.3 0 10.5 10.2 08/11/2005 10:40:00 8.8 1.3 12.2 4.9 8.5 1.1 11.8 5.7 142 8 137 305 10.4 0 10.5 10.2 08/11/2005 10:50:00 8.8 1.4 11.8 4.9 8.7 1.1 11.1 5.7 142 9 147 305 10.6 0 10.8 10.5 08/11/2005 11:00:00 8.2 1.3 11.1 4.2 8 1.1 11.1 5.3 138 10 129 305 10.8 0 10.8 10.5 08/11/2005 11:10:00 8.5 1.2 11.1 5.7 8.4 1.2 11.1 5.7 131 7 132 305 10.9 0 11 10.8 08/11/2005 11:20:00 8.2 1 11.8 5.7 8.1 0.9 11.5 6.1 128 7 134 305 11.3 0 11.3 11 08/11/2005 11:30:00 8.4 0.9 11.1 6.1 8.2 0.9 11.1 6.5 128 6 142 305 11.2 0 11.3 11 08/11/2005 11:40:00 7.3 1 9.9 4.2 7.2 1 9.9 4.2 136 9 140 305 11.5 0.1 11.8 11.3 08/11/2005 11:50:00 7 1.1 9.9 3.4 7.1 0.9 9.5 4.9 142 10 147 305 12 0 12.1 11.8 08/11/2005 12:00:00 6.5 1.2 9.1 3.8 6.8 0.9 9.5 4.2 145 13 134 305 12.2 0 12.4 11.8 08/11/2005 12:10:00 7.1 1.3 9.9 3.8 7.4 1 9.9 4.9 143 10 144 305 12.2 0 12.4 11.8 08/11/2005 12:20:00 7.7 1.5 11.1 3.8 7.7 1.2 10.3 4.9 143 11 141 305 12.2 0 12.4 12.1 08/11/2005 12:30:00 8.2 1.6 11.1 4.2 8.2 1.2 11.1 5.3 142 9 143 305 12 0 12.4 11.8 08/11/2005 12:40:00 7.7 1.5 10.7 3.8 7.5 1.2 11.1 4.6 141 9 132 305 11.9 0 12.1 11.8 08/11/2005 12:50:00 8.2 1 10.3 5.3 7.9 0.9 10.7 5.7 136 8 134 305 12 0 12.1 11.8 08/11/2005 13:00:00 7.9 1 10.7 4.9 7.9 0.9 9.9 5.3 134 9 143 305 12 0 12.1 11.8 08/11/2005 13:10:00 7.4 0.9 9.5 4.2 7.3 0.9 9.9 4.2 130 9 149 305 12.5 0.2 13.2 12.1 08/11/2005 13:20:00 7.6 1 10.3 4.9 7.6 1 10.7 5.3 129 8 139 305 13 0 13.2 12.9 08/11/2005 13:30:00 7.3 1.2 11.1 4.2 7.2 1.2 10.3 3.8 135 10 134 305 12.8 0 13.2 12.6 08/11/2005 13:40:00 6.7 1.3 10.3 3.4 6.8 1.1 9.5 3.8 141 13 134 305 13 0.1 13.4 12.9 08/11/2005 13:50:00 7 1.5 11.1 3.4 7 1.3 10.3 3.8 141 12 135 305 13.4 0 13.7 13.2 08/11/2005 14:00:00 8.2 1.2 10.7 3.8 7.9 1.1 11.1 4.6 139 9 136 305 13.6 0 14 13.7 08/11/2005 14:10:00 8.1 1.2 10.7 4.2 8.1 1 10.3 4.9 139 9 139 305 14 0.2 14.8 13.7 08/11/2005 14:20:00 8 1.3 10.7 3.8 8 1 10.7 5.3 140 8 132 305 14.5 0 14.8 14.3 08/11/2005 14:30:00 7.6 1 10.3 4.6 7.7 0.9 9.9 5.7 139 9 123 305 14.5 0 14.8 14.5 08/11/2005 14:40:00 8.7 1 10.7 4.9 8.5 0.8 10.3 6.5 139 6 142 305 14.2 0 14.5 14 08/11/2005 14:50:00 8.7 1.1 11.5 5.7 8.6 1 11.1 6.5 140 7 136 305 14 0 14.3 14 08/11/2005 15:00:00 8.8 0.8 10.7 5.3 8.7 0.7 11.1 6.8 140 6 138 305 13.6 0.1 14 13.7 08/11/2005 15:10:00 7.8 1.6 10.7 3.8 8.2 1 10.3 5.3 145 8 139 305 13.8 0.3 14.5 13.7 08/11/2005 15:20:00 8 1.4 11.5 4.6 8.2 1 10.7 5.7 142 8 143 305 14.3 0 14.5 14 08/11/2005 15:30:00 8.2 1 11.1 5.3 8.1 0.9 10.3 5.7 142 8 143 305 14.3 0.2 14.8 14.3 08/11/2005 15:40:00 8.5 1.1 11.5 5.3 8.4 1.1 11.8 4.6 132 8 130 305 14.1 0.3 14.8 13.7 08/11/2005 15:50:00 8.6 1.2 12.2 5.7 8.6 1.1 11.1 5.7 132 9 129 305 13.9 0 14.3 13.7 08/11/2005 16:00:00 9.4 1.2 12.6 6.8 9.4 1.2 12.2 6.5 132 8 121 305 13.5 0 13.7 13.4 08/11/2005 16:10:00 9.8 1.1 11.8 5.7 9.5 1.1 11.8 6.1 134 8 133 305 13.3 0.1 13.7 13.2 08/11/2005 16:20:00 8.9 1.1 12.2 5.7 8.9 1 11.8 6.5 136 9 145 305 13.6 0.1 14 13.4 08/11/2005 16:30:00 9 1.1 11.5 6.1 8.8 1 11.5 5.7 136 9 147 305 13.5 0 13.7 13.4 08/11/2005 16:40:00 8.5 1.2 11.5 4.9 8.5 1.2 11.5 5.3 139 10 152 305 13.3 0 13.7 12.9 08/11/2005 16:50:00 8.2 1 10.7 5.7 8.1 1 10.7 6.1 135 11 135 305 13.2 0 13.7 13.2 08/11/2005 17:00:00 9 1.1 12.2 4.6 9 1.1 11.8 6.1 136 9 137 305 12.8 0.2 13.4 12.4 08/11/2005 17:10:00 8.6 1.6 11.8 4.2 8.7 1.3 12.2 4.9 140 11 146 305 12.4 0 12.6 12.1 08/11/2005 17:20:00 7.8 1.7 11.5 4.2 8.4 1.3 12.6 5.7 148 11 139 305 12.5 0 12.9 12.4 08/11/2005 17:30:00 8.2 1.6 11.5 4.6 9 1 11.5 5.7 150 10 159 305 12.7 0 13.2 12.6 08/11/2005 17:40:00 8.3 1.5 11.8 4.9 8.6 1.2 11.5 4.9 148 10 142 305 12.8 0 13.2 12.4 08/11/2005 17:50:00 9.2 1.1 11.8 5.7 9.1 0.9 11.1 6.8 144 7 144 305 12.9 0 13.2 12.6 08/11/2005 18:00:00 9.3 1 11.8 6.8 9.1 0.9 11.8 6.5 138 7 141 305 12.8 0 13.2 12.6 08/11/2005 18:10:00 9.1 0.8 10.7 6.8 9 0.8 11.5 6.5 131 6 136 305 13.1 0 13.4 13.2 08/11/2005 18:20:00 9.8 0.8 12.2 7.2 9.7 0.7 11.8 7.6 131 5 128 305 13.2 0 13.4 13.2 08/11/2005 18:30:00 10.2 1 12.2 6.8 10.1 1 12.2 7.2 133 6 138 305 13 0 13.2 12.9 08/11/2005 18:40:00 10 1.1 12.6 6.5 9.9 1.1 12.6 6.5 138 9 140 305 13 0.1 13.2 12.6 08/11/2005 18:50:00 9.2 1.1 12.2 6.5 9.1 1.1 11.8 6.5 142 9 151 305 12.4 0 12.9 12.1 08/11/2005 19:00:00 8.7 1.3 11.5 5.3 8.7 1.1 11.5 6.1 145 8 137 305 12 0 12.4 11.8 08/11/2005 19:10:00 7.1 1.3 10.3 3.4 7.2 1.1 9.5 4.6 149 9 151 305 11.8 0 11.8 11.6 08/11/2005 19:20:00 6.7 1.1 9.1 4.2 6.8 0.9 8.8 4.2 145 11 148 305 11.7 0 11.8 11.6 08/11/2005 19:30:00 6.4 1.2 9.5 3.8 6.4 1 8.8 3.8 144 10 145 305 11.7 0 11.8 11.6 08/11/2005 19:40:00 6.8 1.1 9.5 4.2 6.8 1 9.1 4.6 144 9 143 305 11.5 0.1 11.8 11.3 08/11/2005 19:50:00 6.4 1.1 8.4 3.4 6.4 1 8.4 3.4 148 10 140 305 11.2 0 11.3 11 08/11/2005 20:00:00 6.3 1.1 9.1 3 6.4 0.9 8.4 3.8 145 9 149 305 11 0 11 10.8 08/11/2005 20:10:00 6.8 1.1 9.5 3.8 6.6 1 8.4 4.2 145 10 147 305 11 0 11.3 11 08/11/2005 20:20:00 6.1 1.3 8.8 3 6.4 1 8.4 4.2 152 10 146 305 11 0 11 11 08/11/2005 20:30:00 5.8 1 8 3.4 6.4 0.9 8.8 3.8 156 12 166 305 11 0 11 11 08/11/2005 20:40:00 5.2 1 7.6 2.6 6.1 0.9 8.4 3.8 168 12 152 305 11 0 11 10.8 08/11/2005 20:50:00 5.1 1 7.6 2.6 5.5 0.9 7.6 2.6 165 13 141 305 10.9 0 11 10.8 08/11/2005 21:00:00 4 1.1 7.2 1.9 4.4 1.1 8.4 2.3 166 15 181 305 11 0 11 10.8 08/11/2005 21:10:00 5 1 7.6 2.3 5.1 1 7.2 2.6 152 18 149 305 10.8 0 11 10.8 08/11/2005 21:20:00 7.1 0.9 9.5 4.6 6.9 1 9.1 3.4 140 7 137 305 10.8 0 11 10.8 08/11/2005 21:30:00 6.3 1.1 9.1 3.8 6.2 1 8.8 4.2 144 12 154 305 10.8 0 10.8 10.8 08/11/2005 21:40:00 7.2 0.9 9.5 4.6 6.9 0.8 9.5 4.6 135 7 128 305 10.7 0 10.8 10.5 08/11/2005 21:50:00 6.7 1.1 9.1 3 6.7 1 9.1 4.2 138 11 131 305 10.5 0 10.8 10.2 08/11/2005 22:00:00 8.7 0.8 10.3 5.7 8.4 0.8 10.3 5.7 135 7 136 305 10.3 0 10.5 10.2 08/11/2005 22:10:00 9.8 0.9 11.5 7.2 9.6 0.9 11.1 6.8 135 4 137 305 10.2 0 10.2 10.2 08/11/2005 22:20:00 9 1.1 11.8 6.5 8.8 1.1 11.5 6.1 137 6 134 305 10.2 0 10.2 10.2 08/11/2005 22:30:00 7 1.3 9.9 4.2 6.8 1.1 9.5 3.8 143 9 149 305 10.2 0 10.2 10.2 08/11/2005 22:40:00 6.2 1.1 9.1 3 6.1 0.9 9.1 3.4 147 12 136 305 10.2 0 10.2 10 08/11/2005 22:50:00 6.8 1 9.5 3 6.6 0.9 9.1 4.6 141 8 141 305 10.1 0 10.2 10 08/11/2005 23:00:00 5.9 1.3 8.8 2.3 5.9 1 8.8 3.4 149 12 141 305 10 0 10.2 10 08/11/2005 23:10:00 5.9 1.2 8.8 2.6 5.9 1 8 3 147 10 142 305 10 0 10.2 10 08/11/2005 23:20:00 4.6 1.3 7.2 1.5 4.6 1.1 6.8 1.9 150 13 138 305 10 0 10.2 10 08/11/2005 23:30:00 6.6 1.2 9.1 3.4 6.5 1.1 9.5 3.4 140 10 145 305 10 0 10.2 10 08/11/2005 23:40:00 6.8 1.4 9.9 3 6.7 1.3 9.5 3.8 144 13 138 305 10 0 10.2 10 08/11/2005 23:50:00 8.5 0.8 10.3 6.5 8.3 0.8 9.9 6.1 140 5 139 305 10 0 10.2 10 08/12/2005 00:00:00 8.2 0.9 9.9 4.6 8.1 0.8 9.9 4.9 139 7 135 305 9.9 0 10.5 10 08/12/2005 00:10:00 9.8 0.8 11.5 8 9.4 0.8 11.5 7.6 132 4 132 305 9.9 0 10 9.7 08/12/2005 00:20:00 8.8 0.6 10.3 6.8 8.5 0.6 10.3 6.8 135 5 137 305 9.8 0 10 9.7 08/12/2005 00:30:00 7.7 1.1 9.9 4.6 7.5 1 9.9 4.9 141 7 140 305 9.8 0 10 9.7 08/12/2005 00:40:00 6.1 1.3 9.1 3 6.1 1.3 9.1 2.6 148 13 133 305 9.8 0 10 9.7 08/12/2005 00:50:00 9.3 1.8 12.2 5.3 9 1.8 12.2 4.9 137 8 129 305 9.8 0 10 9.7 08/12/2005 01:00:00 11.8 1 13.3 8.4 11.4 1 13 7.6 130 3 133 305 9.7 0 9.7 9.7 08/12/2005 01:10:00 11.6 0.9 13.3 8.8 11.3 0.8 13 8.4 132 4 130 305 9.7 0 9.7 9.7 08/12/2005 01:20:00 11.8 0.7 13 9.5 11.6 0.7 13 9.1 133 4 133 305 9.7 0 9.7 9.7 08/12/2005 01:30:00 11.7 0.6 13 9.1 11.4 0.7 13 9.1 132 4 136 305 9.7 0 10 9.7 08/12/2005 01:40:00 11.2 1.2 14.5 8.8 11.1 1.1 13.7 8 125 8 130 305 9.8 0 10 9.7 08/12/2005 01:50:00 11.5 1.3 16.1 7.6 11.4 1.4 16.8 8 120 10 118 305 9.8 0 10 9.7 08/12/2005 02:00:00 11.1 1.3 16.1 7.6 11 1.4 14.9 6.8 124 11 116 305 9.9 0 10 9.7 08/12/2005 02:10:00 10.5 1.2 13.7 7.2 10.3 1.1 13.7 8 133 6 135 305 9.9 0 10 9.7 08/12/2005 02:20:00 9.9 0.6 11.1 8.4 9.6 0.6 11.1 8 132 4 130 305 9.8 0 10 9.7 08/12/2005 02:30:00 8.4 1.2 10.7 5.3 8.1 1.2 10.3 5.3 137 7 132 305 9.7 0 10 9.7 08/12/2005 02:40:00 8.1 1 10.3 4.9 7.9 1 10.3 5.7 140 10 135 305 9.7 0 9.7 9.7 08/12/2005 02:50:00 9 0.8 12.2 6.5 8.6 0.8 11.5 6.5 144 6 150 305 9.7 0 10 9.7 08/12/2005 03:00:00 7.6 1.1 10.3 3.4 7.4 1 9.9 5.3 142 7 144 305 9.8 0 10 9.7 08/12/2005 03:10:00 9.4 1 11.8 6.8 9.2 1 11.8 6.5 137 6 132 305 9.9 0 10 9.7 08/12/2005 03:20:00 9 0.7 11.1 6.8 8.8 0.8 11.5 6.8 136 5 144 305 9.9 0 10 9.7 08/12/2005 03:30:00 7.6 1.6 10.7 3.4 7.3 1.6 10.3 3.4 142 7 138 305 9.9 0 10 9.7 08/12/2005 03:40:00 5.1 1.2 7.6 2.3 5.2 1 7.6 3 145 14 148 305 9.9 0 10 9.7 08/12/2005 03:50:00 6 0.7 7.6 4.6 5.9 0.7 7.6 4.2 137 10 145 305 9.9 0 10 9.7 08/12/2005 04:00:00 5.3 1.3 8.8 2.3 5.2 1 8 3 144 11 150 305 9.9 0 10 9.7 08/12/2005 04:10:00 4.9 1.2 7.6 2.3 4.9 1 7.2 3 144 15 138 305 9.9 0 10 9.7 08/12/2005 04:20:00 3.9 1.1 7.6 1.9 4.1 1.1 7.2 1.9 154 17 147 305 9.9 0 10 9.7 08/12/2005 04:30:00 6.2 0.8 8 3.4 6.1 0.7 8 4.6 143 7 147 305 9.8 0 10 9.7 08/12/2005 04:40:00 5.5 0.8 7.6 3 5.2 0.8 7.2 3.4 137 9 146 305 9.7 0 10 9.7 08/12/2005 04:50:00 7.6 1.2 9.5 3.4 7.4 1.1 9.5 3.4 134 7 128 305 9.7 0 9.7 9.7 08/12/2005 05:00:00 7.3 1 9.1 4.9 7.1 1 9.1 4.9 139 6 135 305 9.7 0 9.7 9.7 08/12/2005 05:10:00 5.5 1.2 8.4 3 5.9 0.7 8 4.2 154 11 147 305 9.7 0 10 9.7 08/12/2005 05:20:00 8.2 0.9 10.3 4.6 7.9 0.8 9.9 5.7 146 6 141 305 9.8 0 10 9.7 08/12/2005 05:30:00 7.7 1 9.9 4.9 7.4 0.9 9.9 4.9 145 8 146 305 9.8 0 10 9.7 08/12/2005 05:40:00 6.2 1.2 8.8 3.4 6.3 1 8.4 4.2 151 11 150 305 9.9 0 10 9.7 08/12/2005 05:50:00 4.9 1.3 8.8 2.3 5.2 1.1 7.6 2.3 160 13 158 305 9.9 0 10 9.7 08/12/2005 06:00:00 5.4 1.7 9.5 2.3 5.4 1.7 9.9 2.6 146 18 129 305 9.8 0 10 9.7 08/12/2005 06:10:00 8.7 1.3 11.1 4.9 8.6 1.2 10.7 4.9 141 9 139 305 9.8 0 10 9.7 08/12/2005 06:20:00 7.5 1.2 9.9 3.4 7.5 0.9 9.5 4.9 150 10 146 305 9.7 0 10 9.7 08/12/2005 06:30:00 7 1.7 11.1 3.4 7.2 1.2 9.9 4.6 154 9 149 305 9.7 0 9.7 9.7 08/12/2005 06:40:00 5.8 1.2 9.1 3 6.4 0.8 8.4 4.6 156 9 154 305 9.7 0 9.7 9.7 08/12/2005 06:50:00 6.6 1.1 9.1 3.8 7 0.8 8.8 4.9 153 9 150 305 9.7 0 9.7 9.7 08/12/2005 07:00:00 7.6 1.4 11.1 3 7.4 1.1 10.3 4.6 146 7 136 305 9.7 0 9.7 9.7 08/12/2005 07:10:00 6.4 1.3 9.5 3.4 6.6 0.9 9.5 3.8 155 12 145 305 9.7 0 9.7 9.7 08/12/2005 07:20:00 6 1.6 10.3 3 6.3 1.2 9.5 3.8 163 17 147 305 9.7 0 10 9.7 08/12/2005 07:30:00 6.7 1.7 9.9 1.9 6.6 1.3 9.1 3.4 146 9 152 305 9.8 0 10 9.7 08/12/2005 07:40:00 5.6 1.1 8.8 3 5.8 1 7.6 2.3 151 12 156 305 9.9 0 10 9.7 08/12/2005 07:50:00 4.8 1.5 9.1 1.5 5.1 1.4 9.1 1.9 162 17 145 305 9.9 0 10 9.7 08/12/2005 08:00:00 5.3 1.5 9.5 2.6 5.7 1.3 8.8 2.6 158 15 162 305 10 0 10.2 10 08/12/2005 08:10:00 5.9 1.4 9.9 2.6 6.1 1.3 9.5 3 155 15 150 305 10.2 0 10.2 10.2 08/12/2005 08:20:00 7 1.6 11.5 3.8 7.4 1.2 10.3 4.9 153 10 146 305 10.2 0 10.2 10 08/12/2005 08:30:00 7.7 1.3 10.7 3.8 7.7 0.9 10.3 4.9 151 8 149 305 10.1 0 10.2 10 08/12/2005 08:40:00 9.3 1.3 11.8 4.6 9.2 1.2 11.5 5.7 143 8 143 305 10.2 0 10.2 10 08/12/2005 08:50:00 8.1 1.7 11.5 3.8 8.3 1.3 11.1 4.6 147 13 129 305 10.2 0 10.5 10.2 08/12/2005 09:00:00 6.5 1.3 10.7 3.4 7.1 1.2 11.5 4.2 170 14 172 305 10.3 0 10.5 10.2 08/12/2005 09:10:00 6.8 1.2 9.9 4.2 8.6 0.9 11.5 6.5 169 8 182 305 10.4 0 10.5 10.2 08/12/2005 09:20:00 6.3 1.1 9.5 4.2 7.8 0.8 10.3 5.3 166 9 186 305 10.6 0 10.8 10.5 08/12/2005 09:30:00 5.9 1.2 9.1 3 6.9 1.1 9.9 4.2 166 12 156 305 10.6 0 10.8 10.5 08/12/2005 09:40:00 6.9 1.2 9.9 4.2 8.6 0.9 11.8 6.5 169 8 177 305 10.7 0 10.8 10.5 08/12/2005 09:50:00 6 1.2 9.1 3.8 7 0.8 9.1 4.6 159 11 144 305 10.7 0 10.8 10.5 08/12/2005 10:00:00 7.5 1.4 10.3 3.4 7.5 1.1 9.5 4.2 151 8 148 305 10.7 0 10.8 10.5 08/12/2005 10:10:00 5 1.2 8 3 5.5 1 8.4 3.4 157 12 138 305 10.8 0 10.8 10.5 08/12/2005 10:20:00 4.2 1 6.8 2.3 4.8 0.7 7.2 3 162 11 147 305 10.9 0 11 10.8 08/12/2005 10:30:00 5.3 1.1 8.4 2.6 5.2 1 8 3 142 13 152 305 11.2 0 11.3 11 08/12/2005 10:40:00 6.3 0.9 8.8 4.6 6.1 0.8 8.4 4.6 139 9 134 305 11.2 0 11.3 11 08/12/2005 10:50:00 7.1 1 9.5 3.8 7 0.9 9.5 5.3 141 9 139 305 11.2 0 11.3 11 08/12/2005 11:00:00 5.8 0.8 7.6 3.4 5.7 0.7 7.6 4.2 143 9 150 305 11.1 0 11.3 10.8 08/12/2005 11:10:00 6.4 0.8 8.4 4.2 6.3 0.8 8.4 3.8 142 8 138 305 11 0 11 10.8 08/12/2005 11:20:00 6.2 0.8 8.4 3.4 6.2 0.8 8.4 4.6 141 8 137 305 11 0 11 10.8 08/12/2005 11:30:00 7.2 1.1 10.3 4.6 7.1 1.1 10.7 4.6 138 9 136 305 11 0 11.3 10.8 08/12/2005 11:40:00 7.5 1 9.5 5.3 7.4 0.9 9.9 5.7 137 10 144 305 11.1 0 11.3 11 08/12/2005 11:50:00 7.7 1.1 11.1 4.9 7.5 1 10.7 4.9 138 9 139 305 11.1 0 11.3 11 08/12/2005 12:00:00 9.4 1 11.5 6.5 9.2 1 11.1 6.5 132 7 136 305 11.2 0 11.3 11 08/12/2005 12:10:00 10.1 0.8 11.8 7.6 9.7 0.9 11.5 7.2 129 5 130 305 11.4 0 11.6 11.3 08/12/2005 12:20:00 9.3 0.8 11.1 6.8 9 0.8 10.7 6.8 130 6 138 305 11.4 0 11.6 11.3 08/12/2005 12:30:00 9.2 1.1 11.5 6.1 8.9 1.1 11.8 5.7 130 8 127 305 11.4 0 11.6 11.3 08/12/2005 12:40:00 7.8 1.3 10.7 3.4 7.8 1.2 10.7 3.4 131 11 156 305 11.4 0 11.6 11.3 08/12/2005 12:50:00 8.5 1.1 11.1 5.3 8.2 1.1 11.1 5.3 132 8 129 305 11.5 0 11.6 11.3 08/12/2005 13:00:00 8.1 0.8 9.9 6.1 7.8 0.8 9.9 5.3 131 6 139 305 11.6 0 11.8 11.3 08/12/2005 13:10:00 7.7 0.9 9.1 5.3 7.5 1 9.5 4.9 132 7 127 305 11.6 0 11.8 11.3 08/12/2005 13:20:00 6.9 1.1 9.5 4.2 6.8 1 8.8 4.2 134 9 130 305 11.5 0 11.6 11.3 08/12/2005 13:30:00 6.4 1 8.8 2.3 6.3 1 9.1 3.4 134 11 138 305 11.6 0.1 11.8 11.3 08/12/2005 13:40:00 5.6 0.8 8 3.4 5.7 0.8 8 3.8 134 12 129 305 11.6 0 11.8 11.3 08/12/2005 13:50:00 5.8 1 8.8 3.4 5.7 0.9 8.4 3.8 140 13 135 305 11.5 0 11.6 11.3 08/12/2005 14:00:00 6.3 1 8.8 3.8 6.2 0.9 8.4 3.8 139 10 145 305 11.4 0 11.6 11.3 08/12/2005 14:10:00 5.6 1 8 3.4 5.5 1 7.6 3.4 140 11 146 305 11.6 0 11.8 11.3 08/12/2005 14:20:00 5.3 0.8 7.2 3 5.3 0.7 7.6 3.4 133 10 125 305 12 0 12.1 11.8 08/12/2005 14:30:00 5.5 1 7.6 3 5.5 0.9 7.6 3.8 138 11 140 305 12.2 0 12.4 12.1 08/12/2005 14:40:00 5.5 0.8 7.6 3 5.6 0.8 7.6 3.8 144 11 131 305 12.2 0.1 12.4 11.8 08/12/2005 14:50:00 4.8 0.8 6.8 2.6 4.9 0.8 6.8 2.6 145 12 147 305 12 0 12.1 11.8 08/12/2005 15:00:00 4.6 0.8 6.8 2.3 4.7 0.8 6.5 2.6 139 12 139 305 11.9 0 12.1 11.8 08/12/2005 15:10:00 3.9 1.1 6.8 1.1 4 1 6.5 1.9 140 15 151 305 11.8 0 11.8 11.6 08/12/2005 15:20:00 4.5 0.7 6.5 2.3 4.4 0.6 5.7 2.6 141 15 127 305 11.9 0 11.8 11.8 08/12/2005 15:30:00 3.6 0.8 6.1 1.5 3.6 0.7 6.5 1.9 135 13 138 305 11.9 0 12.1 11.8 08/12/2005 15:40:00 4.8 1 6.8 1.5 4.6 1 6.8 2.3 132 11 129 305 11.8 0 12.1 11.6 08/12/2005 15:50:00 5.2 0.9 7.2 2.6 5.1 1 7.2 2.6 136 9 137 305 11.8 0 11.8 11.6 08/12/2005 16:00:00 5.1 0.9 6.8 2.6 5 0.8 6.8 2.6 139 12 134 305 11.9 0 11.8 11.8 08/12/2005 16:10:00 5.4 0.7 7.2 3.4 5.4 0.6 7.2 3.8 141 9 149 305 11.8 0 11.8 11.6 08/12/2005 16:20:00 5.2 0.7 6.8 3.4 5.1 0.7 6.8 3 139 9 152 305 11.8 0 11.8 11.6 08/12/2005 16:30:00 4.7 0.9 6.8 2.6 4.6 0.8 6.5 3 145 9 149 305 11.8 0 11.8 11.6 08/12/2005 16:40:00 5 1 7.6 2.6 5 1 7.6 3 141 10 129 305 12 0 12.1 11.8 08/12/2005 16:50:00 5.1 0.8 7.6 3.4 5.2 0.7 6.8 3.4 144 12 150 305 12.1 0.1 12.4 11.8 08/12/2005 17:00:00 4.2 1 6.8 2.3 4.5 0.8 6.5 3 153 12 134 305 12.1 0 12.1 11.6 08/12/2005 17:10:00 5.8 0.8 7.6 3.8 5.6 0.8 7.2 3.4 144 8 152 305 12 0 12.1 11.8 08/12/2005 17:20:00 4.9 1.1 7.2 2.6 5.2 0.8 7.2 3.4 151 12 143 305 12.1 0 12.4 11.8 08/12/2005 17:30:00 5.8 1.1 8 2.6 5.9 0.8 7.6 3.8 149 9 145 305 12.2 0 12.4 12.1 08/12/2005 17:40:00 4.2 1 6.8 1.9 4.6 1 6.8 2.3 165 16 155 305 12.2 0 12.4 12.1 08/12/2005 17:50:00 4.1 1 6.5 1.9 4.2 0.8 6.5 2.3 165 20 112 305 12.1 0 12.4 11.8 08/12/2005 18:00:00 4.1 0.7 6.5 2.3 4.4 0.9 6.5 2.6 193 23 156 305 11.7 0.3 12.1 11 08/12/2005 18:10:00 3.5 0.6 4.9 2.3 3.3 0.5 4.9 1.5 196 10 200 305 11 0 11 10.8 08/12/2005 18:20:00 3.2 0.4 4.2 1.9 3.2 0.4 4.2 2.3 189 6 186 305 10.8 0 11 10.8 08/12/2005 18:30:00 2.5 0.4 3.8 1.5 2.3 0.4 3.4 1.1 205 8 206 305 10.8 0 11 10.8 08/12/2005 18:40:00 2 0.4 3 1.1 1.8 0.4 3 0.7 217 8 210 305 10.8 0 11 10.8 08/12/2005 18:50:00 1.8 0.4 2.6 1.1 1.8 0.3 2.6 0.7 227 8 222 305 10.8 0 10.8 10.5 08/12/2005 19:00:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 215 12 209 305 10.7 0 10.8 10.5 08/12/2005 19:10:00 1.9 0.3 2.6 1.1 1.8 0.3 2.6 0.7 215 6 215 305 10.7 0 10.8 10.5 08/12/2005 19:20:00 1.9 0.3 2.6 1.1 1.7 0.3 2.6 0.7 210 5 211 305 10.6 0 10.8 10.5 08/12/2005 19:30:00 1.6 0.4 2.6 0.7 1.5 0.4 2.6 0.4 208 7 207 305 10.8 0 10.8 10.5 08/12/2005 19:40:00 0.6 0.3 1.9 0.4 0.5 0.2 1.1 0.4 183 23 118 305 10.8 0 11 10.8 08/12/2005 19:50:00 2.4 0.8 4.9 0.4 2.4 0.8 4.6 0.7 159 29 160 305 11.1 0 11.3 10.8 08/12/2005 20:00:00 2.6 1 5.3 0.7 2.8 0.9 4.9 0.4 159 17 151 305 11.2 0 11.3 11 08/12/2005 20:10:00 3.5 0.8 5.3 1.1 3.6 0.8 4.9 1.1 149 11 150 305 11.2 0 11.3 11 08/12/2005 20:20:00 4.6 0.6 6.5 3.4 4.6 0.5 6.1 3.4 138 8 144 305 11.3 0 11.3 11.3 08/12/2005 20:30:00 5 0.7 6.5 3.8 5.1 0.7 6.5 3 136 7 136 305 11.2 0 11.3 11 08/12/2005 20:40:00 5.8 0.6 7.2 4.2 5.7 0.6 7.2 4.2 139 7 140 305 10.9 0 11 10.8 08/12/2005 20:50:00 5.5 0.7 7.6 3.8 5.3 0.7 7.2 3.4 145 7 147 305 10.8 0 10.8 10.8 08/12/2005 21:00:00 6.2 0.7 7.6 4.2 5.9 0.6 7.6 4.2 149 6 151 305 10.8 0 10.8 10.8 08/12/2005 21:10:00 5.7 0.7 7.6 3.8 5.5 0.7 7.2 3.8 146 7 148 305 10.8 0 11 10.8 08/12/2005 21:20:00 4.8 0.6 6.5 2.6 4.6 0.6 6.5 3 143 9 151 305 10.9 0 11 10.8 08/12/2005 21:30:00 5.1 0.7 6.8 3.4 5 0.7 6.5 3 136 8 136 305 10.9 0 11 10.8 08/12/2005 21:40:00 5.7 0.5 6.8 4.2 5.5 0.5 6.8 4.2 131 4 130 305 10.8 0 10.8 10.8 08/12/2005 21:50:00 5.6 0.6 6.8 4.2 5.4 0.6 6.5 4.2 135 5 129 305 10.7 0 10.8 10.5 08/12/2005 22:00:00 4.9 0.7 6.5 3.4 4.7 0.6 6.1 3 141 7 136 305 10.6 0 10.8 10.5 08/12/2005 22:10:00 5.9 0.6 7.2 3.8 5.7 0.6 6.8 3.8 140 6 136 305 10.6 0 10.8 10.5 08/12/2005 22:20:00 6 0.9 8 3.8 5.9 0.7 8 3.8 149 9 153 305 10.6 0 10.8 10.5 08/12/2005 22:30:00 4.9 1 7.2 2.3 5.3 0.9 7.2 3.4 155 8 160 305 10.7 0 10.8 10.5 08/12/2005 22:40:00 4.7 1.1 7.6 2.6 5.3 1 7.6 2.3 158 11 150 305 10.7 0 10.8 10.5 08/12/2005 22:50:00 5.8 1.2 8.4 3 5.6 1 7.6 3 148 8 153 305 10.7 0 10.8 10.5 08/12/2005 23:00:00 6.3 0.7 8 3.8 5.9 0.7 7.6 3.4 142 7 135 305 10.8 0 10.8 10.5 08/12/2005 23:10:00 5.7 1.3 8.4 1.9 5.4 1.4 8 1.5 144 9 143 305 10.8 0 10.8 10.5 08/12/2005 23:20:00 2.4 1.2 5.3 0.4 2.1 1 4.6 0.4 158 35 136 305 10.6 0 10.8 10.5 08/12/2005 23:30:00 1.1 0.8 3.8 0.4 1 0.6 2.6 0.4 253 82 138 305 10.6 0 10.8 10.5 08/12/2005 23:40:00 1.7 1 4.9 0.4 1.7 0.9 5.3 0.4 185 76 141 305 10.7 0 10.8 10.5 08/12/2005 23:50:00 2.7 1.2 5.3 0.4 2.2 1.1 4.9 0.4 140 36 138 305 10.6 0 10.8 10.5 08/13/2005 00:00:00 2.1 0.8 4.6 0.4 1.7 0.8 4.6 0.4 151 45 131 305 10.6 0 10.8 10.5 08/13/2005 00:10:00 1.6 1 4.2 0.4 1.5 0.8 3.8 0.4 257 79 184 305 10.7 0 10.8 10.5 08/13/2005 00:20:00 0.6 0.5 1.9 0.4 0.5 0.3 1.5 0.4 107 102 345 305 10.7 0 10.8 10.5 08/13/2005 00:30:00 1.3 0.8 3.4 0.4 1.2 0.8 3 0.4 165 39 148 305 10.6 0 10.8 10.5 08/13/2005 00:40:00 1.1 0.8 3 0.4 1.1 0.8 3 0.4 160 26 139 305 10.6 0 10.8 10.5 08/13/2005 00:50:00 2.4 1.1 4.6 0.4 2.4 0.9 4.6 0.7 146 16 136 305 10.6 0 10.8 10.5 08/13/2005 01:00:00 2.3 0.8 3.8 0.4 2.2 0.8 4.2 0.4 150 23 151 305 10.6 0 10.8 10.5 08/13/2005 01:10:00 2.5 1 4.9 0.4 2.2 1 4.2 0.4 146 19 137 305 10.6 0 10.5 10.5 08/13/2005 01:20:00 4.8 1 6.8 1.1 4.4 1.1 6.8 1.1 146 9 150 305 10.6 0 10.8 10.5 08/13/2005 01:30:00 2.8 1.3 6.1 0.4 2.8 1.3 6.1 0.4 149 36 154 305 10.6 0 10.8 10.5 08/13/2005 01:40:00 2.1 1 4.9 0.4 1.7 1.1 4.6 0.4 140 38 150 305 10.6 0 10.8 10.5 08/13/2005 01:50:00 2.6 1 4.9 0.4 2.5 1 4.9 0.4 153 22 149 305 10.6 0 10.8 10.5 08/13/2005 02:00:00 1.8 0.9 3.8 0.4 1.8 0.9 3.8 0.4 164 23 173 305 10.4 0 10.8 10.2 08/13/2005 02:10:00 1.2 0.7 3 0.4 1.2 0.7 3 0.4 145 53 120 305 10.3 0 10.5 10.2 08/13/2005 02:20:00 3 1.1 4.9 0.4 2.5 1.1 4.9 0.4 121 17 133 305 10.3 0 10.5 10.2 08/13/2005 02:30:00 1.7 0.8 4.2 0.4 1.6 0.6 2.6 0.4 75 90 120 305 10.4 0 10.5 10.2 08/13/2005 02:40:00 1.3 0.8 3 0.4 1.4 0.8 3.8 0.4 335 86 351 305 10.4 0 10.5 10.2 08/13/2005 02:50:00 2.3 1 4.6 0.4 2.1 1 4.2 0.4 95 30 115 305 10.5 0 10.8 10.2 08/13/2005 03:00:00 2.9 1.2 5.3 0.4 2.6 1 4.9 0.4 99 33 124 305 10.6 0 10.8 10.5 08/13/2005 03:10:00 2.2 0.6 3.8 0.7 2.2 0.6 3.8 0.7 158 21 124 305 10.5 0 10.5 10.5 08/13/2005 03:20:00 1.8 0.8 3.4 0.4 1.7 0.8 3.8 0.4 155 51 158 305 10.3 0 10.5 10.2 08/13/2005 03:30:00 0.8 0.6 3 0.4 0.7 0.6 3 0.4 312 82 186 305 10.3 0 10.5 10.2 08/13/2005 03:40:00 1.8 0.5 3 0.7 1.8 0.5 3 0.7 187 14 196 305 10.3 0 10.2 10.2 08/13/2005 03:50:00 1.8 0.7 3.4 0.4 1.6 0.8 3 0.4 185 17 196 305 10.2 0 10.2 10.2 08/13/2005 04:00:00 1.4 0.6 3 0.4 1.4 0.5 3 0.4 178 27 146 305 10.2 0 10.2 10.2 08/13/2005 04:10:00 2.3 0.8 4.2 0.7 2.5 0.7 4.2 0.7 175 15 189 305 10.2 0 10.2 10 08/13/2005 04:20:00 2.3 0.9 4.2 0.4 2.3 0.9 4.6 0.4 164 20 163 305 10 0 10.2 10 08/13/2005 04:30:00 1 0.8 3.8 0.4 0.9 0.5 2.3 0.4 124 94 123 305 10 0 10.2 10 08/13/2005 04:40:00 3.1 1.1 5.7 0.7 2.7 1.2 6.1 0.4 146 21 145 305 10 0 10.2 10 08/13/2005 04:50:00 2 1.3 5.7 0.4 2.1 1.2 5.3 0.4 137 86 137 305 10 0 10.2 10 08/13/2005 05:00:00 5.5 0.5 6.5 4.2 5.1 0.6 6.8 3.4 145 6 145 305 9.9 0 10.2 10 08/13/2005 05:10:00 5.9 0.5 6.8 4.6 5.4 0.6 6.8 3.8 140 4 136 305 9.9 0 10 9.7 08/13/2005 05:20:00 6.1 0.4 6.8 5.3 5.7 0.4 6.8 4.6 141 3 140 305 9.9 0 10.2 10 08/13/2005 05:30:00 6 0.6 7.2 4.6 5.6 0.6 6.8 4.2 139 3 138 305 10 0 10.2 10 08/13/2005 05:40:00 6.3 0.4 7.2 5.3 5.9 0.4 6.8 4.2 137 3 140 305 10 0 10.2 10 08/13/2005 05:50:00 5.6 0.4 6.5 4.6 5.3 0.5 6.1 4.2 136 3 138 305 10 0 10.2 10 08/13/2005 06:00:00 5.4 0.4 6.5 4.2 5.1 0.4 6.5 4.2 139 4 142 305 9.9 0 10.2 9.7 08/13/2005 06:10:00 5.5 0.5 6.5 3.8 5.2 0.6 6.5 3.4 142 5 141 305 9.8 0 10 9.7 08/13/2005 06:20:00 4.3 0.9 6.5 1.9 4.1 0.8 6.1 1.5 148 7 140 305 9.7 0 10 9.7 08/13/2005 06:30:00 1.9 0.8 4.6 0.4 1.7 0.9 4.2 0.4 161 24 155 305 9.8 0 10 9.7 08/13/2005 06:40:00 1.3 0.8 3.4 0.4 1.1 0.8 3 0.4 142 49 153 305 9.8 0 10 9.7 08/13/2005 06:50:00 1.8 0.7 3.8 0.4 1.7 0.7 4.2 0.4 121 29 106 305 9.8 0 10 9.7 08/13/2005 07:00:00 0.6 0.5 2.6 0.4 0.6 0.4 2.3 0.4 138 45 156 305 9.9 0 10 9.7 08/13/2005 07:10:00 1.5 1 3 0.4 1.3 1 3 0.4 214 24 232 305 9.9 0 10 9.7 08/13/2005 07:20:00 0.9 0.7 2.6 0.4 0.9 0.6 2.6 0.4 256 21 235 305 9.9 0 10.2 9.7 08/13/2005 07:30:00 2.1 0.8 4.2 0.4 1.7 0.8 3.4 0.4 124 56 123 305 10.2 0 10.2 10 08/13/2005 07:40:00 4.7 0.7 6.1 2.6 4.5 0.8 6.1 2.3 125 6 124 305 10.5 0 10.8 10.2 08/13/2005 07:50:00 5.9 0.3 6.5 4.9 5.7 0.4 6.5 4.6 136 4 137 305 10.7 0 10.8 10.5 08/13/2005 08:00:00 5.2 0.5 6.1 3.4 5 0.5 6.1 3.4 144 5 141 305 10.9 0 11 10.8 08/13/2005 08:10:00 4.5 0.5 5.3 3 4.2 0.5 5.3 2.6 143 5 143 305 11.2 0 11.3 11 08/13/2005 08:20:00 4.1 0.7 5.3 2.3 3.9 0.7 5.3 2.3 134 7 135 305 11.5 0.1 11.6 11.3 08/13/2005 08:30:00 3.3 0.9 4.6 0.4 2.9 1.1 4.6 0.4 120 30 131 305 11.5 0 11.6 11.3 08/13/2005 08:40:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 349 51 303 305 11.4 0 11.6 11.3 08/13/2005 08:50:00 1.7 0.4 2.6 0.4 1.9 0.5 3 0.7 10 6 12 305 11.2 0.1 11.3 10.8 08/13/2005 09:00:00 2 0.4 3 1.1 2.3 0.3 3 1.5 34 13 31 305 10.8 0 11 10.5 08/13/2005 09:10:00 0.9 0.6 2.3 0.4 1 0.7 2.3 0.4 75 12 55 305 10.8 0 11 10.5 08/13/2005 09:20:00 0.9 0.5 2.6 0.4 1.2 0.5 3 0.4 34 35 340 305 10.6 0.2 11 10.2 08/13/2005 09:30:00 0.6 0.4 2.6 0.4 0.5 0.2 1.1 0.4 179 66 153 305 10.8 0.1 11 10.5 08/13/2005 09:40:00 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 81 10 77 305 11.1 0 11.3 11 08/13/2005 09:50:00 1 0.4 1.9 0.4 1.2 0.4 1.9 0.4 38 12 41 305 11.2 0 11.3 11 08/13/2005 10:00:00 0.9 0.4 1.9 0.4 1.1 0.5 1.9 0.4 56 13 59 305 11.2 0 11.3 11 08/13/2005 10:10:00 1.1 0.6 2.6 0.4 1.3 0.6 3 0.4 53 22 19 305 11.2 0 11.3 10.8 08/13/2005 10:20:00 1.3 0.7 3 0.4 1.6 0.6 3.4 0.4 358 8 17 305 10.4 0.1 10.8 10.2 08/13/2005 10:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 16 7 4 305 10.6 0 10.8 10.2 08/13/2005 10:40:00 0.7 0.4 1.5 0.4 0.8 0.4 1.9 0.4 351 26 0 305 11 0 11.3 10.8 08/13/2005 10:50:00 0.6 0.3 1.1 0.4 0.6 0.3 1.5 0.4 325 22 329 305 11.3 0 11.6 11 08/13/2005 11:00:00 0.7 0.4 1.9 0.4 0.7 0.3 1.5 0.4 12 22 21 305 11.8 0 11.8 11.6 08/13/2005 11:10:00 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 26 24 18 305 11.9 0 11.8 11.6 08/13/2005 11:20:00 1.6 0.4 2.6 0.4 1.7 0.3 2.6 1.1 28 13 41 305 11.8 0 11.8 11.6 08/13/2005 11:30:00 2 0.4 3 1.1 2.3 0.4 3 1.5 32 8 49 305 11.6 0.1 11.8 11.3 08/13/2005 11:40:00 1.9 0.5 3 0.7 2.2 0.4 3 0.7 32 7 22 305 11.8 0 11.8 11.3 08/13/2005 11:50:00 2.2 0.4 3 1.1 2.5 0.4 3.4 1.5 31 8 36 305 11.9 0 12.1 11.6 08/13/2005 12:00:00 1.8 0.4 2.6 1.1 2.2 0.3 3 1.5 21 6 28 305 11.8 0 11.8 11.6 08/13/2005 12:10:00 2.4 0.5 3.8 1.1 2.8 0.4 3.8 1.5 25 8 28 305 11.4 0.3 12.1 11 08/13/2005 12:20:00 1.9 0.8 3.8 0.4 2.5 0.7 4.2 0.7 30 9 30 305 11.5 0 11.8 11.3 08/13/2005 12:30:00 1.6 0.9 4.2 0.4 1.9 0.7 3.8 0.4 62 47 146 305 12.4 0.4 13.2 11.6 08/13/2005 12:40:00 2 0.5 3.8 0.7 2.1 0.7 4.2 0.4 146 13 171 305 13.6 0.3 14.3 13.2 08/13/2005 12:50:00 1.3 0.7 2.6 0.4 1.4 0.6 3 0.4 349 94 10 305 13.6 0.4 14.3 13.2 08/13/2005 13:00:00 1.8 0.4 3.4 0.7 2.2 0.4 3.4 1.1 331 12 346 305 13.2 0 13.7 13.2 08/13/2005 13:10:00 3.2 1 5.3 1.5 3.5 0.9 5.3 1.9 10 19 29 305 12.4 0.7 13.2 11.3 08/13/2005 13:20:00 3.3 0.6 4.6 1.5 3.7 0.6 4.9 2.3 38 11 30 305 11.4 0.1 11.6 11 08/13/2005 13:30:00 2.2 0.7 4.2 0.4 2.6 0.6 4.2 1.1 47 6 51 305 11.4 0.1 11.8 11.3 08/13/2005 13:40:00 1.6 0.6 3.4 0.4 2 0.6 3.8 0.7 24 12 39 305 12.2 0.2 12.9 11.8 08/13/2005 13:50:00 1.1 0.4 2.6 0.4 1.6 0.4 3.4 0.7 7 11 21 305 13 0 13.2 12.9 08/13/2005 14:00:00 2.1 0.8 4.2 0.7 2.5 0.8 4.6 1.1 12 10 26 305 12.8 0.4 13.4 12.1 08/13/2005 14:10:00 1.4 0.4 2.6 0.7 2 0.4 3 1.1 15 9 24 305 13 0.1 13.4 12.4 08/13/2005 14:20:00 1.6 0.4 2.6 0.4 2.1 0.5 3.4 1.1 42 10 54 305 13 0 13.2 12.9 08/13/2005 14:30:00 3.3 1.5 5.7 0.7 3.9 1.3 6.1 1.1 45 9 45 305 12.2 0.5 12.9 11.3 08/13/2005 14:40:00 3.9 0.6 5.3 1.9 4.7 0.5 5.7 3.4 38 7 40 305 11.2 0 11.3 11 08/13/2005 14:50:00 3 0.6 4.2 1.5 3.6 0.6 4.9 2.3 44 6 46 305 11.4 0 11.6 11.3 08/13/2005 15:00:00 3 0.4 4.2 1.5 3.7 0.4 4.6 2.3 49 6 52 305 11.4 0 11.8 11.3 08/13/2005 15:10:00 2.4 0.6 3.8 0.4 3 0.7 4.2 0.4 57 14 59 305 11.7 0 11.8 11.6 08/13/2005 15:20:00 1.8 1.7 4.9 0.4 2.2 1.7 5.3 0.4 92 56 44 305 12.1 0.3 12.6 11.6 08/13/2005 15:30:00 4.3 0.5 5.7 3 4.6 0.5 5.7 2.6 44 3 44 305 11.4 0 11.8 11.3 08/13/2005 15:40:00 3.8 0.2 4.6 3 4.2 0.3 4.9 3.4 42 2 42 305 11.8 0 11.8 11.6 08/13/2005 15:50:00 4.8 0.4 5.7 4.2 5.1 0.3 5.7 4.2 43 2 41 305 11.8 0 12.1 11.6 08/13/2005 16:00:00 5.7 0.3 6.5 4.9 5.8 0.3 6.5 5.3 45 3 47 305 11.6 0.1 11.8 11.3 08/13/2005 16:10:00 4.5 0.4 5.7 3.8 4.7 0.4 6.1 3.8 48 2 49 305 11.4 0 11.6 11.3 08/13/2005 16:20:00 4.4 0.3 4.9 3.8 4.5 0.3 4.9 3.4 44 4 42 305 11.4 0 11.6 11.3 08/13/2005 16:30:00 4.8 0.2 5.3 4.2 4.7 0.2 5.3 3.8 41 3 36 305 11.4 0 11.6 11.3 08/13/2005 16:40:00 4.7 0.2 4.9 4.2 4.5 0.2 4.9 3.8 48 2 51 305 11.6 0 11.8 11.3 08/13/2005 16:50:00 4.7 0.2 5.3 4.2 4.6 0.3 5.3 3.8 46 2 46 305 11.6 0 11.8 11.6 08/13/2005 17:00:00 4.1 0.2 4.6 3.4 4 0.2 4.6 3.4 42 3 41 305 11.9 0 12.1 11.6 08/13/2005 17:10:00 4.2 0.2 4.6 3.8 4.1 0.2 4.6 3.4 34 2 35 305 11.6 0.2 11.8 11.3 08/13/2005 17:20:00 3.8 0.2 4.2 3.4 3.8 0.2 4.2 3 26 3 31 305 11.2 0 11.3 11 08/13/2005 17:30:00 3.7 0.3 4.2 3 3.5 0.3 4.2 2.6 35 4 41 305 11.3 0 11.3 11 08/13/2005 17:40:00 3.2 0.3 3.8 2.3 3.2 0.3 3.8 2.3 26 11 30 305 11.2 0 11.3 11 08/13/2005 17:50:00 3.2 0.2 3.8 2.6 3.2 0.3 3.8 2.3 13 4 7 305 11 0 11.3 11 08/13/2005 18:00:00 3.4 0.2 3.8 3 3.4 0.2 3.8 2.6 20 7 8 305 11 0 11.3 10.8 08/13/2005 18:10:00 3.5 0.2 3.8 3 3.4 0.2 3.8 3 22 4 26 305 11.1 0 11.3 11 08/13/2005 18:20:00 3.3 0.2 3.8 2.6 3.3 0.2 3.8 2.6 16 3 14 305 11 0 11.3 10.8 08/13/2005 18:30:00 3.6 0.4 4.2 2.6 3.5 0.3 4.2 2.6 19 4 19 305 11 0 11 11 08/13/2005 18:40:00 3.9 0.2 4.2 3.4 4 0.2 4.6 3.4 25 2 27 305 11 0 11 11 08/13/2005 18:50:00 3.7 0.2 4.2 3 3.8 0.2 4.2 3.4 22 2 22 305 11 0 11 10.8 08/13/2005 19:00:00 3.6 0.3 4.6 3 3.6 0.3 4.2 3 29 9 34 305 11 0 11.3 11 08/13/2005 19:10:00 3.9 0.2 4.6 3.4 3.9 0.2 4.6 3.4 35 5 37 305 11 0 11.3 10.8 08/13/2005 19:20:00 3.6 0.2 4.2 3 3.6 0.3 4.2 2.6 32 6 24 305 10.8 0 11 10.8 08/13/2005 19:30:00 3.9 0.2 4.6 3.4 3.8 0.2 4.2 3.4 34 6 42 305 10.8 0 11 10.8 08/13/2005 19:40:00 3.5 0.3 4.2 3 3.4 0.3 4.2 3 31 6 39 305 10.7 0 10.8 10.5 08/13/2005 19:50:00 3.4 0.2 3.8 3 3.3 0.2 3.8 2.6 31 5 31 305 10.8 0 11 10.8 08/13/2005 20:00:00 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 31 9 26 305 10.8 0 10.8 10.8 08/13/2005 20:10:00 3.8 0.3 4.2 3 3.7 0.3 4.2 3 32 5 32 305 10.8 0 10.8 10.5 08/13/2005 20:20:00 3.5 0.3 4.2 3 3.6 0.2 4.2 3 36 3 39 305 10.8 0 11 10.8 08/13/2005 20:30:00 3.4 0.2 4.2 3 3.4 0.3 3.8 2.6 34 9 19 305 10.7 0 11 10.5 08/13/2005 20:40:00 3.4 0.2 3.8 3 3.5 0.2 4.2 3 33 4 30 305 10.6 0 10.8 10.5 08/13/2005 20:50:00 3.3 0.3 3.8 2.6 3.3 0.3 3.8 2.6 34 7 29 305 10.6 0 10.8 10.5 08/13/2005 21:00:00 3.3 0.2 3.8 2.6 3.2 0.3 3.8 2.3 27 5 21 305 10.4 0 10.5 10.2 08/13/2005 21:10:00 3 0.2 3.4 2.6 2.9 0.2 3.4 2.6 28 6 34 305 10.4 0 10.5 10.2 08/13/2005 21:20:00 2.9 0.2 3.4 2.3 2.8 0.2 3.4 2.3 28 5 19 305 10.3 0 10.5 10.2 08/13/2005 21:30:00 2.7 0.2 3 2.3 2.7 0.2 3 2.3 22 3 32 305 10.3 0 10.5 10.2 08/13/2005 21:40:00 2.3 0.4 3 1.1 2.3 0.4 3 1.1 24 6 20 305 10.3 0 10.5 10.2 08/13/2005 21:50:00 2.2 0.2 2.6 1.5 2.1 0.3 2.6 1.1 22 5 11 305 10.3 0 10.2 10.2 08/13/2005 22:00:00 2.6 0.3 3.4 1.9 2.3 0.2 3 1.5 34 8 40 305 10.3 0 10.5 10.2 08/13/2005 22:10:00 2.3 0.4 3.4 1.5 2 0.3 2.6 1.5 27 3 23 305 10.3 0 10.5 10.2 08/13/2005 22:20:00 1.9 0.4 2.6 1.5 1.7 0.3 2.6 1.1 33 11 39 305 10.3 0 10.5 10.2 08/13/2005 22:30:00 2.5 0.2 3 1.9 2.3 0.2 2.6 1.5 42 4 45 305 10.3 0 10.5 10.2 08/13/2005 22:40:00 2.5 0.2 3 1.9 2.3 0.2 2.6 1.9 41 3 45 305 10.4 0 10.5 10.2 08/13/2005 22:50:00 2.6 0.3 3.4 1.9 2.3 0.3 3 1.5 38 5 41 305 10.4 0 10.5 10.2 08/13/2005 23:00:00 2.9 0.2 3.4 2.3 2.5 0.3 3 1.5 51 4 44 305 10.3 0 10.5 10 08/13/2005 23:10:00 2.6 0.2 3 1.9 2.4 0.3 3 1.1 37 10 51 305 10 0 10.2 10 08/13/2005 23:20:00 2.2 0.3 3 1.5 2.1 0.3 2.6 1.5 35 6 29 305 10 0.1 10.2 9.7 08/13/2005 23:30:00 1.6 0.2 1.9 1.1 1.6 0.2 1.9 1.1 29 3 29 305 9.7 0 10 9.5 08/13/2005 23:40:00 1.7 0.2 2.3 1.1 1.5 0.3 1.9 0.7 22 5 14 305 9.7 0 10 9.5 08/13/2005 23:50:00 2.5 1.2 4.6 1.1 2.4 1.2 4.9 1.1 349 27 316 305 9.3 0.1 9.7 8.9 08/14/2005 00:00:00 2.7 0.7 4.2 1.1 2.7 0.7 4.2 1.1 342 15 316 305 9.2 0 9.5 8.9 08/14/2005 00:10:00 2.4 0.4 3 1.1 2.2 0.6 3 0.4 356 9 340 305 9.2 0 9.2 9.2 08/14/2005 00:20:00 1.7 0.3 2.3 0.7 1.2 0.5 2.3 0.4 5 6 353 305 9.2 0 9.2 9.2 08/14/2005 00:30:00 1.5 0.2 1.9 1.1 1.6 0.2 1.9 1.1 12 3 16 305 9.2 0 9.2 9.2 08/14/2005 00:40:00 1.6 0.3 2.3 1.1 1.7 0.3 2.3 1.1 6 6 12 305 9.1 0 9.2 8.9 08/14/2005 00:50:00 1.6 0.2 2.3 1.1 1.7 0.3 2.3 1.1 16 6 8 305 9.1 0 9.2 8.9 08/14/2005 01:00:00 1.7 0.4 2.6 0.7 1.8 0.4 2.6 0.7 3 7 355 305 8.8 0 9.2 8.7 08/14/2005 01:10:00 1.2 0.4 1.9 0.4 1.3 0.3 1.9 0.4 25 7 23 305 8.6 0 8.9 8.4 08/14/2005 01:20:00 1.1 0.4 1.9 0.4 1.1 0.4 2.3 0.4 28 9 18 305 8.6 0 8.7 8.4 08/14/2005 01:30:00 1.7 0.4 2.6 0.4 1.8 0.4 2.6 0.7 28 9 37 305 8.4 0 8.7 8.2 08/14/2005 01:40:00 1.9 0.4 3 1.1 2.1 0.4 3.4 1.5 9 9 14 305 8.2 0 8.4 8.2 08/14/2005 01:50:00 1.7 0.3 2.6 1.1 1.8 0.3 2.6 1.1 359 5 352 305 8.1 0 8.2 7.9 08/14/2005 02:00:00 1.9 0.2 2.6 1.1 1.9 0.3 2.6 1.1 16 6 18 305 8 0 8.2 7.9 08/14/2005 02:10:00 1.5 0.5 2.6 0.4 1.5 0.4 2.3 0.4 17 7 5 305 8 0 8.2 7.9 08/14/2005 02:20:00 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 18 10 18 305 7.9 0.1 7.9 7.7 08/14/2005 02:30:00 1.1 0.4 2.3 0.4 1.1 0.5 2.3 0.4 21 6 25 305 7.8 0 7.9 7.7 08/14/2005 02:40:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 24 8 32 305 7.8 0 7.9 7.7 08/14/2005 02:50:00 1.5 0.4 2.3 0.4 1.3 0.4 2.3 0.4 25 11 16 305 7.8 0 7.9 7.7 08/14/2005 03:00:00 1.2 0.5 2.3 0.4 1.1 0.5 1.9 0.4 27 20 16 305 7.8 0 7.9 7.7 08/14/2005 03:10:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 21 13 32 305 7.7 0 7.9 7.7 08/14/2005 03:20:00 1.5 0.3 2.3 0.7 1.5 0.3 2.3 0.7 27 9 27 305 7.9 0 7.9 7.7 08/14/2005 03:30:00 1.9 0.4 2.6 0.7 1.7 0.4 2.6 0.7 27 12 17 305 8 0 8.2 7.9 08/14/2005 03:40:00 2 0.4 3 1.1 2 0.4 3 1.1 34 9 37 305 8 0 8.2 7.9 08/14/2005 03:50:00 1.9 0.3 2.6 0.7 1.8 0.3 2.3 1.1 44 13 38 305 8 0 8.2 7.9 08/14/2005 04:00:00 1.5 0.2 2.3 1.1 1.4 0.2 2.3 0.7 49 10 31 305 8 0 8.2 7.9 08/14/2005 04:10:00 1.7 0.3 2.3 1.1 1.5 0.3 1.9 0.7 58 6 58 305 8 0 8.2 7.9 08/14/2005 04:20:00 1.4 0.2 1.9 0.7 1.2 0.2 1.9 0.7 37 5 32 305 8.1 0 8.2 7.9 08/14/2005 04:30:00 1.4 0.2 1.9 0.7 1.3 0.2 1.9 0.7 38 7 36 305 8.1 0 8.2 8.2 08/14/2005 04:40:00 1.8 0.4 2.6 1.1 1.7 0.3 2.6 1.1 35 9 13 305 8.2 0 8.4 8.2 08/14/2005 04:50:00 2 0.3 2.6 1.1 1.9 0.2 2.6 1.1 37 5 29 305 8.4 0 8.4 8.2 08/14/2005 05:00:00 2.6 0.3 3.4 1.9 2.4 0.3 3.4 1.9 32 5 32 305 8.4 0 8.4 8.2 08/14/2005 05:10:00 2.9 0.3 3.4 2.3 2.7 0.2 3.4 2.3 31 6 20 305 8.6 0 8.7 8.4 08/14/2005 05:20:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 33 6 28 305 8.7 0 8.9 8.4 08/14/2005 05:30:00 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 38 7 42 305 8.8 0 9.2 8.7 08/14/2005 05:40:00 3.3 0.3 3.8 2.6 3.3 0.3 3.8 2.6 32 5 22 305 8.8 0 9.2 8.7 08/14/2005 05:50:00 3.4 0.3 4.2 2.6 3.4 0.2 4.2 2.6 34 4 31 305 8.8 0 8.9 8.7 08/14/2005 06:00:00 3.8 0.4 4.9 3 3.8 0.3 4.6 3 39 6 29 305 8.9 0 8.9 8.4 08/14/2005 06:10:00 4.1 0.2 4.6 3.4 4 0.2 4.6 3.4 31 4 38 305 8.8 0 8.9 8.7 08/14/2005 06:20:00 3.9 0.2 4.6 3.4 3.9 0.2 4.6 3.4 32 4 32 305 8.8 0 8.9 8.7 08/14/2005 06:30:00 4.2 0.3 4.9 3.4 4.2 0.2 4.9 3.4 32 4 33 305 8.8 0 8.9 8.7 08/14/2005 06:40:00 4.8 0.2 5.3 4.2 4.5 0.2 4.9 4.2 26 3 24 305 8.6 0 8.9 8.4 08/14/2005 06:50:00 5.4 0.3 6.5 4.6 5.3 0.4 6.1 4.2 25 2 25 305 8.7 0 8.9 8.4 08/14/2005 07:00:00 5.8 0.4 7.2 4.9 5.6 0.5 7.2 4.6 28 3 29 305 8.8 0 8.9 8.7 08/14/2005 07:10:00 6.6 0.4 7.6 5.3 6.6 0.4 7.6 5.3 29 3 29 305 8.6 0.1 8.9 8.2 08/14/2005 07:20:00 6.4 0.4 7.2 5.3 6.4 0.4 7.6 5.3 34 3 30 305 8.2 0 8.4 8.2 08/14/2005 07:30:00 6.5 0.5 7.2 5.3 6.4 0.5 7.6 4.9 32 3 27 305 8.1 0 8.2 8.2 08/14/2005 07:40:00 5.9 0.4 6.8 4.9 5.8 0.4 6.8 4.9 38 3 31 305 8.2 0 8.4 8.2 08/14/2005 07:50:00 5.2 0.3 6.1 4.2 5.1 0.4 5.7 3.8 39 4 42 305 8.2 0 8.4 8.2 08/14/2005 08:00:00 5.2 0.3 6.1 4.6 5.1 0.3 6.1 4.6 34 4 41 305 8.4 0 8.4 8.2 08/14/2005 08:10:00 4.9 0.3 5.7 3.8 4.9 0.3 5.7 3.8 38 4 37 305 8.6 0 8.7 8.4 08/14/2005 08:20:00 4.9 0.4 5.7 3.8 4.8 0.4 5.7 3.8 36 5 38 305 8.8 0 9.2 8.7 08/14/2005 08:30:00 4.7 0.4 5.7 3.8 4.6 0.4 5.3 3.8 35 4 33 305 9.1 0 9.2 8.9 08/14/2005 08:40:00 5.4 0.3 6.1 4.6 5.4 0.3 6.1 4.6 27 3 28 305 9.1 0 9.2 8.9 08/14/2005 08:50:00 5.5 0.3 6.1 4.9 5.3 0.3 6.1 4.6 26 3 26 305 9.2 0 9.5 9.2 08/14/2005 09:00:00 5.7 0.3 6.5 4.9 5.6 0.3 6.1 4.9 29 4 33 305 9.3 0 9.5 9.2 08/14/2005 09:10:00 5.7 0.3 6.5 4.6 5.6 0.3 6.1 4.6 31 5 30 305 9.4 0 9.7 9.2 08/14/2005 09:20:00 5.8 0.4 6.5 4.9 5.7 0.4 6.5 4.6 34 4 33 305 9.5 0 9.7 9.5 08/14/2005 09:30:00 6.5 0.3 7.2 5.7 6.4 0.3 7.2 5.7 31 3 32 305 9.6 0 9.7 9.5 08/14/2005 09:40:00 7.3 0.4 8.4 6.1 7 0.4 8 6.1 28 3 25 305 9.7 0 9.7 9.5 08/14/2005 09:50:00 7.6 0.3 8.8 6.8 7.4 0.3 8.4 6.5 28 3 31 305 9.7 0 10 9.7 08/14/2005 10:00:00 7.6 0.4 8.8 6.8 7.4 0.3 8.4 6.5 33 3 39 305 9.8 0 10 9.7 08/14/2005 10:10:00 8.6 0.4 9.5 7.6 8.4 0.4 9.5 7.2 30 4 35 305 9.8 0 10 9.7 08/14/2005 10:20:00 8.4 0.4 9.5 7.2 8.3 0.4 9.1 7.2 32 3 31 305 9.8 0 10 9.7 08/14/2005 10:30:00 8.1 0.4 9.1 7.2 7.9 0.4 9.1 6.5 35 3 32 305 9.9 0 10 9.7 08/14/2005 10:40:00 8.5 0.4 9.5 7.6 8.2 0.4 9.5 6.8 34 3 32 305 10 0 10.2 9.7 08/14/2005 10:50:00 8.8 0.4 9.9 7.6 8.5 0.4 9.5 6.8 33 3 32 305 10.2 0 10.2 10 08/14/2005 11:00:00 8.4 0.4 9.5 7.6 8.3 0.4 9.1 7.2 34 3 35 305 10.2 0 10.2 10 08/14/2005 11:10:00 8.3 0.4 9.5 7.2 8.2 0.4 9.5 7.2 36 3 31 305 10.3 0 10.5 10.2 08/14/2005 11:20:00 8.2 0.5 9.1 6.5 8 0.5 9.1 6.8 37 4 32 305 10.4 0 10.8 10.2 08/14/2005 11:30:00 8 0.4 9.1 6.5 7.8 0.5 8.8 6.5 38 3 32 305 10.6 0 10.8 10.2 08/14/2005 11:40:00 7.8 0.4 8.8 6.5 7.6 0.4 8.8 6.1 37 4 39 305 10.6 0 10.8 10.5 08/14/2005 11:50:00 7.8 0.4 9.1 6.8 7.7 0.5 8.8 6.1 39 5 32 305 10.9 0 11 10.8 08/14/2005 12:00:00 8.9 0.5 9.9 7.6 8.6 0.5 9.9 7.6 39 4 37 305 10.8 0 11 10.5 08/14/2005 12:10:00 8.9 0.4 9.9 8 8.7 0.4 9.5 7.2 38 3 39 305 10.8 0 11 10.5 08/14/2005 12:20:00 8.9 0.4 9.9 8 8.6 0.4 9.9 7.6 39 3 40 305 10.9 0.1 11 10.5 08/14/2005 12:30:00 8.7 0.4 9.9 7.6 8.6 0.4 9.5 7.6 37 3 40 305 11 0.1 11.3 10.8 08/14/2005 12:40:00 8.6 0.3 9.5 7.6 8.4 0.4 9.5 7.2 34 3 35 305 11 0 11.3 10.8 08/14/2005 12:50:00 8.8 0.4 9.9 7.6 8.5 0.4 9.5 7.2 35 3 32 305 11.1 0 11.3 11 08/14/2005 13:00:00 8.8 0.4 9.9 7.6 8.6 0.4 9.5 7.2 37 3 43 305 11.1 0 11.3 10.8 08/14/2005 13:10:00 9 0.4 10.7 8 8.7 0.4 9.5 7.2 34 3 34 305 11.1 0 11.3 10.8 08/14/2005 13:20:00 8.4 0.4 9.5 7.6 8.2 0.4 9.1 6.8 36 3 37 305 11 0 11.3 10.8 08/14/2005 13:30:00 8.3 0.5 9.5 7.2 8 0.5 9.1 6.8 35 3 38 305 11.2 0 11.3 11 08/14/2005 13:40:00 8.3 0.4 9.1 7.2 8.1 0.4 9.1 6.8 37 3 32 305 11.1 0.1 11.3 10.8 08/14/2005 13:50:00 8.4 0.4 9.5 7.2 8.2 0.3 9.1 7.2 39 4 38 305 11 0 11.3 10.8 08/14/2005 14:00:00 8.5 0.4 9.9 7.2 8.3 0.5 9.5 6.8 41 4 48 305 11.2 0.1 11.3 11 08/14/2005 14:10:00 8.6 0.5 9.5 6.8 8.3 0.5 9.9 6.8 42 4 41 305 11.6 0.1 11.8 11.3 08/14/2005 14:20:00 8.3 0.4 9.5 6.5 8.1 0.5 9.5 6.5 44 5 45 305 11.4 0 11.6 11.3 08/14/2005 14:30:00 8.1 0.4 9.5 6.8 7.9 0.5 9.5 6.5 41 5 47 305 11.6 0 11.8 11.3 08/14/2005 14:40:00 7.9 0.4 8.8 6.8 7.7 0.4 8.8 6.5 39 4 46 305 11.5 0 11.8 11.3 08/14/2005 14:50:00 7.9 0.5 9.5 6.8 7.7 0.5 8.8 6.1 40 5 35 305 11.8 0 11.8 11.3 08/14/2005 15:00:00 8.2 0.6 9.9 6.8 8 0.5 9.5 6.5 42 6 37 305 11.8 0 11.8 11.6 08/14/2005 15:10:00 8.6 0.6 10.3 6.8 8.4 0.6 9.9 6.5 42 5 42 305 11.9 0 12.1 11.6 08/14/2005 15:20:00 8.4 0.6 10.3 6.5 8.3 0.7 10.3 6.5 41 4 33 305 11.8 0 12.1 11.6 08/14/2005 15:30:00 8.5 0.5 9.9 6.8 8.5 0.5 9.9 6.5 41 5 48 305 11.8 0 12.1 11.6 08/14/2005 15:40:00 9 0.5 11.1 7.6 9 0.5 10.7 7.2 43 5 43 305 11.7 0.1 11.8 11.3 08/14/2005 15:50:00 9.2 0.6 10.7 7.6 9.1 0.6 10.7 7.2 43 5 46 305 11.8 0 11.8 11.6 08/14/2005 16:00:00 9 0.6 10.7 7.2 8.9 0.6 10.3 7.2 43 6 40 305 11.7 0 11.8 11.3 08/14/2005 16:10:00 9 0.6 10.7 7.2 8.9 0.6 10.7 6.8 43 5 42 305 11.8 0 11.8 11.6 08/14/2005 16:20:00 8.5 0.7 10.3 6.5 8.4 0.7 10.3 6.5 44 7 40 305 11.7 0.1 12.1 11.3 08/14/2005 16:30:00 8.5 0.7 10.3 6.8 8.3 0.7 10.3 6.1 43 6 44 305 11.6 0.1 11.8 11.3 08/14/2005 16:40:00 8.5 0.7 10.3 5.7 8.3 0.7 9.9 5.3 44 7 34 305 11.7 0 12.1 11.3 08/14/2005 16:50:00 8.7 0.6 10.3 6.8 8.6 0.6 10.3 7.2 42 6 38 305 11.6 0 11.8 11.3 08/14/2005 17:00:00 8.3 0.7 10.3 6.1 8.3 0.7 10.3 5.7 42 5 45 305 11.8 0 11.8 11.6 08/14/2005 17:10:00 7.8 0.6 10.7 5.7 7.7 0.6 9.5 6.1 41 5 30 305 11.8 0.1 12.1 11.3 08/14/2005 17:20:00 8.4 0.5 9.5 6.8 8.3 0.6 9.5 6.5 43 5 39 305 11.7 0 11.8 11.3 08/14/2005 17:30:00 9 0.7 11.5 7.2 8.9 0.7 11.1 7.2 43 7 41 305 11.8 0 12.1 11.6 08/14/2005 17:40:00 9.4 0.8 11.5 7.6 9.3 0.8 11.5 7.6 42 6 36 305 11.7 0 11.8 11.6 08/14/2005 17:50:00 9.5 0.6 11.5 8 9.4 0.6 11.8 7.2 42 5 32 305 11.8 0 12.1 11.6 08/14/2005 18:00:00 9.3 0.8 12.2 6.8 9.2 0.9 12.2 7.2 42 5 49 305 11.9 0 12.1 11.6 08/14/2005 18:10:00 8.5 0.6 10.3 7.2 8.5 0.6 10.3 6.8 44 5 47 305 11.9 0 12.1 11.6 08/14/2005 18:20:00 8.1 0.5 9.5 6.8 8.1 0.5 9.5 6.5 43 6 52 305 11.7 0 11.8 11.3 08/14/2005 18:30:00 7.2 0.6 9.1 5.7 7.1 0.5 8.8 5.7 49 7 42 305 11.7 0 11.8 11.6 08/14/2005 18:40:00 7.1 0.6 8.8 5.7 7.1 0.6 8.8 5.7 45 8 31 305 11.8 0 12.1 11.6 08/14/2005 18:50:00 7 0.6 9.1 5.3 6.9 0.7 8.8 5.3 44 7 44 305 11.7 0 11.8 11.3 08/14/2005 19:00:00 7 0.5 8.4 5.7 7.1 0.5 8.8 5.7 42 5 40 305 11.6 0 11.8 11.3 08/14/2005 19:10:00 7 0.6 9.1 5.7 6.9 0.6 8.8 5.3 44 6 44 305 11.4 0 11.6 11.3 08/14/2005 19:20:00 7.7 0.5 9.1 6.5 7.6 0.6 9.1 6.1 44 5 42 305 11.3 0 11.3 11.3 08/14/2005 19:30:00 8.5 1 11.5 6.5 8.4 1 11.1 5.7 45 5 53 305 11.2 0 11.3 11 08/14/2005 19:40:00 9.6 0.7 11.8 7.6 9.6 0.7 11.8 7.6 48 6 46 305 11 0 11.3 10.8 08/14/2005 19:50:00 9.8 0.8 11.5 6.8 9.8 0.8 11.8 7.2 49 6 40 305 11.1 0 11.3 11 08/14/2005 20:00:00 9.9 0.6 11.8 8.4 9.7 0.7 11.5 7.6 49 6 48 305 11 0 11.3 10.8 08/14/2005 20:10:00 9.3 0.6 10.7 7.6 9.2 0.6 11.1 7.2 46 6 46 305 10.8 0 11 10.8 08/14/2005 20:20:00 8.7 0.7 10.7 6.8 8.7 0.6 10.7 7.2 45 5 51 305 10.6 0 10.8 10.5 08/14/2005 20:30:00 8.1 0.5 9.5 6.8 8.1 0.5 9.5 6.1 43 6 44 305 10.5 0 10.8 10.2 08/14/2005 20:40:00 7.8 0.4 9.1 6.8 7.8 0.4 9.1 6.5 44 5 42 305 10.4 0 10.5 10.2 08/14/2005 20:50:00 7.4 0.4 8.4 6.5 7.4 0.4 8.8 6.1 42 4 46 305 10.3 0 10.5 10.2 08/14/2005 21:00:00 7.8 0.4 8.4 6.8 7.8 0.3 8.8 6.8 41 4 45 305 10.2 0 10.2 10 08/14/2005 21:10:00 8 0.4 9.1 6.5 7.9 0.5 9.1 6.5 43 5 41 305 10.2 0 10.2 10.2 08/14/2005 21:20:00 8 0.5 9.1 6.8 8.1 0.5 9.5 7.2 42 4 46 305 10.2 0 10.5 10.2 08/14/2005 21:30:00 8.3 0.5 9.5 6.8 8.4 0.5 9.9 6.8 43 5 41 305 10.3 0 10.5 10.2 08/14/2005 21:40:00 8.2 0.5 9.5 6.8 8.2 0.6 9.5 6.5 43 5 41 305 10.3 0 10.5 10.2 08/14/2005 21:50:00 7.8 0.6 9.5 6.1 7.8 0.6 9.5 6.1 44 6 41 305 10.3 0 10.5 10.2 08/14/2005 22:00:00 8 0.5 9.5 6.5 8 0.5 9.1 7.2 43 5 46 305 10.2 0 10.2 10.2 08/14/2005 22:10:00 8 0.6 9.9 6.1 8 0.6 9.9 6.5 42 5 46 305 10.2 0 10.2 10.2 08/14/2005 22:20:00 7.8 0.4 9.1 6.5 7.8 0.5 8.8 6.8 44 5 47 305 10.2 0 10.2 10 08/14/2005 22:30:00 7.8 0.5 9.5 6.5 7.7 0.5 9.5 6.1 43 5 39 305 10 0 10.2 10 08/14/2005 22:40:00 7.7 0.4 9.1 6.5 7.7 0.5 8.8 6.5 42 4 42 305 10 0 10.2 9.7 08/14/2005 22:50:00 8 0.6 9.9 6.5 7.9 0.6 9.5 6.5 42 4 47 305 9.9 0 10 9.7 08/14/2005 23:00:00 8.1 0.4 9.5 7.2 8.2 0.4 9.5 7.2 42 4 45 305 9.8 0 10 9.7 08/14/2005 23:10:00 8 0.4 9.1 6.8 8.1 0.4 9.1 6.8 40 4 39 305 9.6 0 9.7 9.5 08/14/2005 23:20:00 8.2 0.5 9.9 7.2 8.1 0.4 9.1 6.8 39 4 29 305 9.3 0 9.5 9.2 08/14/2005 23:30:00 8.2 0.4 9.1 7.2 8.2 0.4 9.5 7.2 42 4 38 305 9.3 0 9.5 9.2 08/14/2005 23:40:00 7.8 0.4 8.8 6.8 7.8 0.4 8.8 6.8 40 4 45 305 9.2 0 9.2 9.2 08/14/2005 23:50:00 7.7 0.4 8.8 6.8 7.7 0.4 9.1 6.8 35 3 40 305 9.2 0 9.5 9.2 08/15/2005 00:00:00 7.9 0.4 9.1 6.8 7.8 0.4 8.8 6.8 37 4 34 305 9.2 0 9.5 9.2 08/15/2005 00:10:00 7.8 0.3 8.4 6.8 7.8 0.3 8.8 6.8 39 3 37 305 9.2 0 9.5 9.2 08/15/2005 00:20:00 8.1 0.5 10.3 7.2 8.2 0.4 9.9 7.2 37 3 38 305 9.2 0 9.5 9.2 08/15/2005 00:30:00 8.5 0.4 9.5 7.6 8.5 0.4 9.5 7.2 40 4 43 305 9.2 0 9.5 9.2 08/15/2005 00:40:00 8.7 0.4 9.9 7.6 8.7 0.4 9.9 7.6 40 3 36 305 9.2 0 9.5 9.2 08/15/2005 00:50:00 9.1 0.5 10.3 8 9.2 0.5 10.3 8 43 4 44 305 9.3 0 9.5 9.2 08/15/2005 01:00:00 9.9 0.5 11.5 8.8 9.9 0.5 11.1 8.8 44 5 45 305 9.4 0 9.7 9.2 08/15/2005 01:10:00 10.3 0.5 11.8 8.8 10.2 0.5 11.8 8.8 44 4 40 305 9.4 0 9.7 9.2 08/15/2005 01:20:00 10.1 0.5 11.5 8.4 10.1 0.5 11.5 8.4 43 4 50 305 9.4 0 9.5 9.2 08/15/2005 01:30:00 9.8 0.5 11.1 8 9.8 0.6 11.5 8 45 4 41 305 9.4 0 9.7 9.2 08/15/2005 01:40:00 9.8 0.6 11.5 7.6 9.7 0.7 11.8 7.6 44 4 39 305 9.4 0 9.7 9.2 08/15/2005 01:50:00 9.4 0.6 11.1 7.6 9.3 0.7 11.1 7.2 46 5 49 305 9.3 0 9.5 9.2 08/15/2005 02:00:00 9.7 0.5 11.5 8 9.7 0.6 11.5 8 45 5 48 305 9.4 0 9.5 9.2 08/15/2005 02:10:00 9.8 0.6 11.5 7.6 9.8 0.7 11.5 7.6 45 4 44 305 9.4 0 9.7 9.2 08/15/2005 02:20:00 9.2 0.5 10.7 8 9.3 0.5 10.7 7.6 44 5 48 305 9.4 0 9.5 9.2 08/15/2005 02:30:00 9.1 0.5 11.5 7.6 9.1 0.5 10.7 7.6 41 5 52 305 9.3 0 9.5 9.2 08/15/2005 02:40:00 9 0.4 9.9 8 8.9 0.5 10.3 7.6 39 4 33 305 9.2 0 9.2 9.2 08/15/2005 02:50:00 8.7 0.3 9.5 7.6 8.7 0.4 9.9 7.2 39 4 37 305 9.2 0 9.2 8.9 08/15/2005 03:00:00 8.7 0.4 9.5 7.6 8.5 0.4 9.9 6.8 40 4 38 305 9.1 0 9.2 8.9 08/15/2005 03:10:00 8.8 0.5 10.7 7.2 8.7 0.6 10.3 7.2 41 5 42 305 9.1 0 9.2 9.2 08/15/2005 03:20:00 9.2 0.4 10.3 8.4 9.2 0.5 10.7 7.6 42 4 51 305 9.2 0 9.5 9.2 08/15/2005 03:30:00 8.9 0.4 10.3 7.6 9 0.4 10.3 8 43 4 46 305 9.2 0 9.5 9.2 08/15/2005 03:40:00 8.8 0.4 9.9 8 8.8 0.5 9.9 6.8 42 4 43 305 9.2 0 9.5 9.2 08/15/2005 03:50:00 8.8 0.3 9.5 7.6 8.8 0.3 9.9 7.6 41 3 37 305 9.1 0 9.2 8.9 08/15/2005 04:00:00 9.1 0.4 10.3 8 9.1 0.4 10.3 8 43 4 47 305 9.1 0 9.2 8.9 08/15/2005 04:10:00 9.7 0.4 10.7 8.8 9.7 0.4 10.7 8.8 41 3 36 305 9.1 0 9.2 8.9 08/15/2005 04:20:00 9.9 0.3 10.7 8.8 9.9 0.3 10.7 9.1 41 2 40 305 9.1 0 9.2 8.9 08/15/2005 04:30:00 9.7 0.4 10.7 8.8 9.6 0.4 10.7 8.8 42 3 42 305 9.1 0 9.2 8.9 08/15/2005 04:40:00 9.8 0.4 10.7 8.8 9.8 0.4 11.1 8.8 44 3 40 305 9.2 0 9.2 9.2 08/15/2005 04:50:00 10.2 0.4 11.1 9.1 10.2 0.4 11.1 9.1 45 4 41 305 9.2 0 9.2 9.2 08/15/2005 05:00:00 10 0.4 11.1 8.8 9.9 0.4 11.1 8.8 43 3 41 305 9.1 0 9.2 8.9 08/15/2005 05:10:00 9.8 0.4 10.7 8.8 9.8 0.4 10.7 8.8 44 3 49 305 9.1 0 9.2 8.9 08/15/2005 05:20:00 9.7 0.4 10.7 8.8 9.6 0.4 10.7 8 46 4 48 305 9.2 0 9.5 9.2 08/15/2005 05:30:00 9.9 0.5 11.5 8.8 9.8 0.5 11.5 8.4 44 4 42 305 9.2 0 9.5 9.2 08/15/2005 05:40:00 10.2 0.5 11.5 9.1 10.1 0.5 11.5 8.8 44 3 43 305 9.3 0 9.5 9.2 08/15/2005 05:50:00 10.5 0.6 12.2 8.8 10.4 0.6 12.2 8.8 46 5 45 305 9.3 0 9.5 9.2 08/15/2005 06:00:00 10.2 0.5 11.5 8.8 10 0.6 11.5 8.4 48 5 56 305 9.2 0 9.5 9.2 08/15/2005 06:10:00 10 0.6 11.8 8.4 9.8 0.6 11.5 8 47 5 44 305 9.2 0 9.5 9.2 08/15/2005 06:20:00 10 0.5 11.8 8.4 9.9 0.6 11.5 8.4 49 4 50 305 9.2 0 9.5 9.2 08/15/2005 06:30:00 10 0.5 11.5 8.8 9.8 0.6 11.5 8.4 50 4 46 305 9.2 0 9.5 9.2 08/15/2005 06:40:00 9.9 0.5 11.5 8.4 9.8 0.5 11.1 8.4 51 5 44 305 9.3 0 9.5 9.2 08/15/2005 06:50:00 9.2 0.5 11.1 8 9 0.5 10.3 7.6 51 5 60 305 9.2 0 9.5 9.2 08/15/2005 07:00:00 9.4 0.5 11.1 8 9.2 0.5 10.7 8 50 5 40 305 9.2 0 9.5 9.2 08/15/2005 07:10:00 9.7 0.5 11.1 8 9.4 0.5 11.1 8.4 52 4 44 305 9.3 0 9.5 9.2 08/15/2005 07:20:00 9.5 0.5 10.7 8.4 9.4 0.5 11.1 8 53 5 54 305 9.4 0 9.5 9.2 08/15/2005 07:30:00 9.5 0.5 10.7 8.4 9.3 0.5 10.7 8 52 5 48 305 9.5 0 9.7 9.2 08/15/2005 07:40:00 10 0.6 12.2 8.8 9.7 0.6 11.8 8.4 51 4 47 305 9.5 0 9.7 9.5 08/15/2005 07:50:00 10.6 0.8 13 8.8 10.2 0.8 12.2 8.4 51 5 46 305 9.6 0 9.7 9.5 08/15/2005 08:00:00 10.1 0.6 12.2 8.4 9.7 0.6 12.2 8.4 53 5 48 305 9.7 0 9.7 9.5 08/15/2005 08:10:00 10.4 0.6 13.3 9.1 10 0.7 12.2 8.4 53 5 48 305 9.8 0 10 9.7 08/15/2005 08:20:00 10.1 0.6 12.6 8 9.7 0.6 11.8 8 54 5 39 305 9.8 0 10 9.7 08/15/2005 08:30:00 9.9 0.6 11.8 8 9.6 0.6 11.5 8 52 6 53 305 9.9 0 10 9.7 08/15/2005 08:40:00 10 0.7 12.2 8.4 9.6 0.7 12.2 7.6 50 5 48 305 9.9 0 10 10 08/15/2005 08:50:00 9.8 0.7 11.5 8 9.4 0.6 11.1 8 52 5 46 305 10 0 10 10 08/15/2005 09:00:00 9.5 0.6 11.1 8 9.2 0.6 11.1 7.6 51 5 51 305 10 0 10.2 10 08/15/2005 09:10:00 9.4 0.6 11.5 8 9.1 0.5 10.7 7.6 49 5 49 305 10.1 0 10.2 10 08/15/2005 09:20:00 9.2 0.6 10.7 7.6 8.9 0.6 10.3 7.2 49 5 48 305 10.2 0 10.2 10 08/15/2005 09:30:00 9.5 0.7 11.5 8 9.1 0.6 11.1 7.2 49 5 46 305 10.2 0 10.2 10.2 08/15/2005 09:40:00 9.7 0.7 12.2 7.2 9.3 0.8 11.8 7.2 51 5 43 305 10.3 0 10.5 10.2 08/15/2005 09:50:00 9.1 0.6 11.1 7.6 8.8 0.6 10.7 6.8 51 5 47 305 10.3 0 10.5 10.2 08/15/2005 10:00:00 8.4 0.6 10.3 6.8 8.2 0.6 10.3 6.8 50 5 46 305 10.3 0 10.5 10.2 08/15/2005 10:10:00 8.6 0.6 10.3 7.2 8.3 0.6 10.3 6.8 49 5 52 305 10.3 0 10.5 10.2 08/15/2005 10:20:00 8.7 0.6 11.1 7.2 8.3 0.6 10.3 6.5 49 5 44 305 10.4 0 10.5 10.2 08/15/2005 10:30:00 9 0.6 11.1 7.2 8.7 0.7 11.1 7.2 49 6 44 305 10.4 0 10.5 10.2 08/15/2005 10:40:00 8.9 0.6 10.7 7.2 8.5 0.7 10.3 6.8 49 5 50 305 10.4 0 10.8 10.2 08/15/2005 10:50:00 8.4 0.6 10.3 6.8 8.1 0.6 9.5 6.8 50 6 40 305 10.5 0 10.8 10.5 08/15/2005 11:00:00 8.4 0.6 10.3 6.8 8.1 0.7 10.3 6.5 50 5 44 305 10.6 0 10.8 10.5 08/15/2005 11:10:00 8.7 0.7 10.7 7.2 8.4 0.7 10.3 6.1 47 5 46 305 10.7 0 10.8 10.5 08/15/2005 11:20:00 8.9 0.6 10.7 7.2 8.4 0.6 10.3 6.8 46 6 31 305 10.7 0 10.8 10.5 08/15/2005 11:30:00 8.7 0.7 11.1 7.2 8.4 0.7 10.3 6.8 46 5 48 305 10.8 0 11 10.5 08/15/2005 11:40:00 8.7 0.7 11.1 6.8 8.2 0.7 10.3 6.8 46 6 37 305 10.8 0 11 10.8 08/15/2005 11:50:00 8.7 0.8 10.7 6.5 8.3 0.8 11.1 6.1 44 5 43 305 11 0.1 11.3 10.8 08/15/2005 12:00:00 9 0.7 10.7 7.2 8.6 0.8 10.7 6.8 44 5 45 305 11 0 11.3 10.8 08/15/2005 12:10:00 9 0.7 11.1 7.2 8.6 0.7 10.7 6.8 45 5 48 305 11 0 11.3 10.8 08/15/2005 12:20:00 8.9 0.6 10.7 7.2 8.6 0.6 10.3 7.2 45 6 37 305 11.2 0 11.3 10.8 08/15/2005 12:30:00 8.9 0.6 10.7 7.2 8.6 0.7 10.3 6.5 47 5 43 305 11.2 0 11.3 11 08/15/2005 12:40:00 9 0.6 10.7 7.6 8.6 0.7 10.7 6.8 47 5 40 305 11.3 0 11.6 11 08/15/2005 12:50:00 9.1 0.6 11.1 7.2 8.7 0.7 10.3 6.8 46 5 35 305 11.2 0 11.3 11 08/15/2005 13:00:00 9.3 0.7 11.5 6.8 8.9 0.8 11.5 6.5 46 5 42 305 11.4 0 11.6 11.3 08/15/2005 13:10:00 8.9 0.7 10.7 7.2 8.6 0.7 10.7 6.5 46 6 54 305 11.4 0 11.6 11.3 08/15/2005 13:20:00 8.9 0.8 11.1 6.8 8.6 0.8 10.7 6.1 48 6 48 305 11.4 0 11.6 11.3 08/15/2005 13:30:00 8.6 0.7 10.3 6.8 8.3 0.8 10.3 6.5 50 5 58 305 11.4 0 11.6 11 08/15/2005 13:40:00 8.5 0.6 10.7 6.8 8.2 0.7 10.3 6.1 49 5 49 305 11.4 0.1 11.8 11.3 08/15/2005 13:50:00 8.2 0.6 9.9 6.5 7.8 0.7 9.5 5.7 48 6 41 305 11.6 0.1 11.8 11.3 08/15/2005 14:00:00 8.4 0.6 10.3 6.8 8.1 0.7 10.3 6.1 48 5 48 305 11.4 0 11.6 11.3 08/15/2005 14:10:00 8.4 0.5 9.9 7.2 8.1 0.6 9.9 6.1 46 5 48 305 11.4 0 11.8 11.3 08/15/2005 14:20:00 8.9 0.7 11.1 7.2 8.7 0.8 10.7 6.5 43 5 48 305 11.4 0 11.6 11.3 08/15/2005 14:30:00 9.2 0.7 11.5 7.2 8.8 0.8 10.7 6.8 43 5 41 305 11.6 0 11.8 11.3 08/15/2005 14:40:00 9.3 0.7 11.1 7.6 8.9 0.7 10.7 7.2 42 5 37 305 11.4 0.1 11.8 11.3 08/15/2005 14:50:00 9.2 0.7 11.1 7.6 8.9 0.7 11.5 7.2 42 5 40 305 11.4 0 11.6 11.3 08/15/2005 15:00:00 9.2 0.6 11.1 7.2 8.9 0.7 10.7 7.2 44 4 45 305 11.4 0 11.6 11.3 08/15/2005 15:10:00 9.2 0.5 10.3 7.6 8.8 0.5 9.9 7.2 43 5 35 305 11.3 0 11.3 11 08/15/2005 15:20:00 9.1 0.6 11.5 7.2 8.7 0.7 10.3 7.2 43 4 43 305 11.4 0 11.6 11 08/15/2005 15:30:00 9 0.5 10.7 7.2 8.5 0.6 9.9 6.5 42 4 36 305 11.1 0 11.3 11 08/15/2005 15:40:00 9 0.5 10.7 7.6 8.6 0.6 10.3 7.2 42 4 40 305 11 0 11.3 10.8 08/15/2005 15:50:00 8.7 0.5 10.3 7.2 8.2 0.6 9.9 6.5 44 4 41 305 10.8 0 11 10.5 08/15/2005 16:00:00 8.8 0.6 10.7 7.2 8.2 0.6 9.9 6.5 42 4 43 305 10.8 0 11.3 10.5 08/15/2005 16:10:00 8.7 0.5 10.3 7.2 8.1 0.6 9.9 5.7 42 5 46 305 10.8 0 11 10.5 08/15/2005 16:20:00 8 0.4 9.1 6.5 7.6 0.4 8.8 6.1 44 4 45 305 10.8 0 11 10.5 08/15/2005 16:30:00 8.1 0.5 9.5 6.8 7.7 0.6 9.1 5.7 45 4 44 305 10.7 0 10.8 10.5 08/15/2005 16:40:00 8.4 0.4 9.5 7.2 8 0.5 9.1 6.5 44 5 44 305 10.4 0 10.8 10.2 08/15/2005 16:50:00 8.4 0.4 9.5 7.2 8 0.5 9.5 6.1 42 4 45 305 10.6 0.1 10.8 10.2 08/15/2005 17:00:00 8.4 0.5 9.5 7.2 8.1 0.5 9.1 6.8 43 4 41 305 10.3 0 10.5 10.2 08/15/2005 17:10:00 8.3 0.4 9.5 6.8 8.1 0.5 9.1 6.5 44 4 41 305 10.4 0 10.8 10.2 08/15/2005 17:20:00 8.7 0.5 9.9 7.2 8.4 0.5 9.9 6.1 44 5 38 305 10.3 0 10.8 10.2 08/15/2005 17:30:00 8.4 0.5 9.9 6.8 8.1 0.5 9.1 6.8 44 5 40 305 10.2 0 10.5 10 08/15/2005 17:40:00 8.9 0.6 10.7 6.8 8.4 0.6 10.7 6.8 46 5 41 305 10.2 0 10.5 10 08/15/2005 17:50:00 8.7 0.5 10.3 6.8 8.4 0.6 9.9 6.8 49 5 55 305 10.5 0.1 10.8 10.2 08/15/2005 18:00:00 8.7 0.6 10.7 6.8 8.4 0.6 9.9 6.8 47 5 44 305 10.4 0.1 10.8 10 08/15/2005 18:10:00 8.8 0.6 10.3 6.8 8.6 0.6 10.7 6.8 51 5 55 305 10.4 0 10.8 10.2 08/15/2005 18:20:00 9.2 0.7 11.8 7.2 9 0.7 11.1 6.8 49 6 41 305 10.5 0.1 10.8 10.2 08/15/2005 18:30:00 8.9 0.6 10.7 7.6 8.8 0.7 11.1 7.2 51 5 52 305 10.4 0 10.8 10.2 08/15/2005 18:40:00 8.5 0.8 10.7 6.1 8.3 0.8 10.7 6.5 51 7 41 305 10.9 0 11.3 10.5 08/15/2005 18:50:00 8.9 0.7 10.7 7.2 8.7 0.7 10.3 6.8 53 7 56 305 10.8 0 11 10.5 08/15/2005 19:00:00 9.4 0.7 11.1 7.2 9.3 0.7 11.1 7.2 54 7 51 305 11 0 11.3 10.8 08/15/2005 19:10:00 9.4 0.8 11.5 7.6 9.5 0.8 11.8 7.6 55 7 60 305 11 0 11.3 10.8 08/15/2005 19:20:00 9.9 0.8 11.8 7.6 9.8 0.8 12.2 8 56 6 54 305 11 0 11.3 10.8 08/15/2005 19:30:00 9.6 0.8 12.2 6.8 9.6 0.8 13.3 7.2 56 6 57 305 10.9 0 11 10.8 08/15/2005 19:40:00 9.9 0.9 12.2 7.6 9.9 0.9 12.6 7.6 57 6 69 305 10.9 0 11 10.8 08/15/2005 19:50:00 9.7 0.7 11.5 7.2 9.6 0.8 12.6 6.8 56 7 53 305 10.8 0 11 10.8 08/15/2005 20:00:00 9.6 0.8 11.5 7.2 9.6 0.8 11.8 7.2 57 6 61 305 10.8 0 11 10.5 08/15/2005 20:10:00 9.4 0.7 11.1 7.6 9.3 0.8 11.1 7.2 53 7 54 305 10.6 0.2 10.8 10.2 08/15/2005 20:20:00 9 0.8 11.1 6.8 8.8 0.8 10.7 6.1 54 8 62 305 10.4 0.1 10.8 10.2 08/15/2005 20:30:00 9 0.8 11.5 6.8 8.7 0.7 10.3 6.8 55 6 53 305 10.3 0 10.5 10.2 08/15/2005 20:40:00 9.4 0.7 11.8 7.6 9.1 0.8 11.5 7.6 54 6 39 305 10.2 0 10.2 10 08/15/2005 20:50:00 9.2 0.7 10.7 6.8 9 0.8 11.1 6.8 54 7 61 305 10.1 0 10.2 10 08/15/2005 21:00:00 9.2 0.7 11.1 7.2 8.9 0.7 10.7 6.8 55 8 46 305 10.2 0 10.2 10 08/15/2005 21:10:00 9.3 0.7 11.1 7.2 9.1 0.7 11.1 6.5 54 6 48 305 9.9 0 10.2 9.7 08/15/2005 21:20:00 9.7 0.8 11.8 7.6 9.6 0.8 11.5 7.6 57 7 41 305 10 0.2 10.2 9.7 08/15/2005 21:30:00 9.6 0.9 11.8 6.8 9.5 0.9 11.5 6.8 58 7 54 305 10.2 0 10.2 10 08/15/2005 21:40:00 10.2 0.9 13.7 8 10.2 0.8 12.6 8 59 7 56 305 10.1 0 10.2 10 08/15/2005 21:50:00 10.1 0.8 12.2 8.4 10.2 0.7 12.2 8 59 6 63 305 10.2 0 10.2 10 08/15/2005 22:00:00 10.1 0.9 13 7.6 10.1 0.9 12.2 8 58 6 54 305 10.1 0 10.2 10 08/15/2005 22:10:00 10.1 0.8 13 8.4 10.2 0.7 12.6 8.4 58 6 61 305 10 0 10.2 10 08/15/2005 22:20:00 10.2 0.8 12.6 8 10.2 0.7 12.6 8.8 57 6 57 305 10.1 0 10.2 10 08/15/2005 22:30:00 10.4 0.8 12.6 8 10.4 0.7 13 8.4 59 6 59 305 10.1 0 10.2 10 08/15/2005 22:40:00 10.8 0.7 12.6 8.4 10.8 0.6 12.6 8.8 57 5 52 305 10 0 10.2 10 08/15/2005 22:50:00 10.8 0.6 12.6 9.5 10.8 0.6 12.2 9.1 57 4 54 305 10 0 10.2 10 08/15/2005 23:00:00 10.7 0.8 13.3 8.8 10.7 0.8 12.6 8.8 59 6 56 305 9.9 0 10.2 10 08/15/2005 23:10:00 10.7 0.6 12.6 8.8 10.8 0.6 12.2 9.5 59 5 60 305 9.9 0 10 9.7 08/15/2005 23:20:00 11.1 0.6 13 9.1 11.2 0.5 13 9.9 59 4 48 305 9.8 0 10 9.7 08/15/2005 23:30:00 11.1 0.6 12.6 9.5 11.1 0.6 13 9.5 59 5 57 305 9.8 0 10 9.7 08/15/2005 23:40:00 10.9 0.5 12.6 9.1 11 0.5 12.2 9.9 58 5 51 305 9.7 0 9.7 9.7 08/15/2005 23:50:00 11.4 0.7 13.3 8.8 11.3 0.7 13.7 8.8 56 5 58 305 9.8 0 10 9.7 08/16/2005 00:00:00 11.5 0.7 13.7 9.5 11.4 0.7 14.1 9.9 58 5 64 305 9.8 0 10.5 9.7 08/16/2005 00:10:00 11.4 0.5 13 10.3 11.4 0.5 12.6 10.3 59 4 63 305 9.7 0 10 9.5 08/16/2005 00:20:00 11.1 0.7 13 8.8 11 0.6 13 9.1 57 5 57 305 9.6 0 9.7 9.5 08/16/2005 00:30:00 11.1 0.5 12.2 8.8 11.1 0.5 12.2 9.5 57 4 52 305 9.5 0 9.7 9.5 08/16/2005 00:40:00 10.9 0.7 12.2 9.1 10.9 0.6 12.6 8.8 59 5 52 305 9.5 0 9.7 9.5 08/16/2005 00:50:00 10.3 0.7 12.2 8 10.3 0.6 12.2 8.8 61 6 58 305 9.5 0 9.7 9.5 08/16/2005 01:00:00 9.9 0.5 11.5 8.4 10 0.5 11.8 8.8 60 5 67 305 9.5 0 9.7 9.5 08/16/2005 01:10:00 10.2 0.6 11.8 8.8 10.2 0.6 11.8 8.8 60 5 57 305 9.5 0 9.7 9.5 08/16/2005 01:20:00 9.8 0.8 12.2 8.4 9.9 0.6 12.2 8.4 59 5 62 305 9.5 0 9.7 9.5 08/16/2005 01:30:00 10.3 0.7 11.8 8.4 10.3 0.7 12.2 8.4 58 5 56 305 9.4 0 9.7 9.2 08/16/2005 01:40:00 10.5 0.6 12.2 9.1 10.5 0.6 12.6 8.8 57 5 61 305 9.5 0 9.7 9.5 08/16/2005 01:50:00 10 0.6 11.8 8 10.1 0.6 11.5 8.8 54 5 44 305 9.3 0 9.5 9.2 08/16/2005 02:00:00 9.8 0.6 11.8 8.4 9.8 0.6 11.5 8 56 5 54 305 9.3 0 9.5 9.2 08/16/2005 02:10:00 9.3 0.7 11.5 7.2 9.4 0.7 11.5 7.2 50 8 49 305 9.2 0 9.5 8.9 08/16/2005 02:20:00 9.3 0.6 11.1 7.6 9.3 0.6 11.1 7.2 52 6 47 305 8.9 0 9.2 8.7 08/16/2005 02:30:00 9.8 0.6 11.5 8 9.9 0.6 11.8 8.8 56 4 57 305 9 0 9.2 8.9 08/16/2005 02:40:00 10 0.5 11.5 8.8 10.1 0.5 11.5 8.8 55 4 48 305 8.9 0 9.2 8.7 08/16/2005 02:50:00 9.5 0.5 11.1 8.4 9.5 0.5 11.8 8.4 53 5 59 305 8.9 0 9.2 8.9 08/16/2005 03:00:00 9.6 0.8 11.5 7.6 9.5 0.8 11.1 7.6 49 5 49 305 8.8 0 9.2 8.4 08/16/2005 03:10:00 9.3 0.5 11.1 8 9.3 0.5 10.7 8.4 47 4 44 305 8.4 0.1 8.9 8.2 08/16/2005 03:20:00 9.6 0.5 11.5 8.4 9.5 0.5 10.7 8 44 4 42 305 8.2 0.1 8.4 7.9 08/16/2005 03:30:00 9.9 0.6 11.8 8.8 9.9 0.6 11.8 8.4 43 5 49 305 8.1 0 8.2 7.9 08/16/2005 03:40:00 9.7 0.5 10.7 8 9.7 0.5 11.5 8.4 42 4 40 305 8 0 8.2 7.9 08/16/2005 03:50:00 9.7 0.7 11.8 8.4 9.7 0.6 11.8 8.4 40 3 41 305 7.7 0 7.9 7.7 08/16/2005 04:00:00 9.7 0.5 11.1 8.4 9.7 0.5 11.1 8.4 41 3 40 305 7.7 0 7.9 7.4 08/16/2005 04:10:00 10.1 0.5 11.5 8.8 10 0.5 11.5 8.8 42 3 39 305 7.5 0 7.7 7.4 08/16/2005 04:20:00 10.2 0.5 11.8 9.1 10.1 0.5 11.5 9.1 43 3 41 305 7.5 0 7.7 7.4 08/16/2005 04:30:00 11 0.6 12.6 9.5 10.9 0.6 12.6 8.8 41 3 42 305 7.5 0 7.7 7.4 08/16/2005 04:40:00 10.8 0.6 12.2 9.5 10.7 0.6 12.2 9.1 43 3 43 305 7.4 0 7.7 7.2 08/16/2005 04:50:00 10.8 0.8 12.6 8.8 10.7 0.8 12.2 8.8 45 3 44 305 7.3 0 7.7 7.2 08/16/2005 05:00:00 10.6 0.6 12.6 9.1 10.4 0.6 12.2 9.1 46 3 48 305 7.2 0 7.4 7.2 08/16/2005 05:10:00 10.4 0.4 11.8 9.1 10.4 0.5 11.8 9.1 50 4 49 305 7.3 0 7.7 7.2 08/16/2005 05:20:00 10.4 0.6 12.6 9.1 10.2 0.6 12.2 8.8 46 4 39 305 7.2 0 7.4 7.2 08/16/2005 05:30:00 10.6 0.6 12.2 9.5 10.5 0.5 11.8 9.1 43 3 44 305 7.1 0 7.4 6.9 08/16/2005 05:40:00 10.8 0.7 12.6 9.1 10.6 0.7 12.6 8.8 43 3 42 305 6.9 0 7.2 6.9 08/16/2005 05:50:00 10.5 0.8 12.2 8.8 10.3 0.8 12.2 8.8 47 4 39 305 7 0 7.2 6.9 08/16/2005 06:00:00 10.8 0.5 11.8 9.1 10.6 0.5 11.8 8.8 51 3 50 305 7 0 7.7 6.9 08/16/2005 06:10:00 10.8 0.7 12.6 8.8 10.7 0.8 13 8.8 55 5 59 305 7.3 0.2 7.9 6.9 08/16/2005 06:20:00 11 0.6 13 9.1 10.9 0.6 12.2 9.1 53 4 50 305 7.4 0.2 8.2 7.2 08/16/2005 06:30:00 10.6 0.6 12.2 9.1 10.5 0.6 12.2 8.8 50 4 53 305 7.4 0.1 7.9 7.2 08/16/2005 06:40:00 11.1 0.6 12.6 8.8 10.9 0.6 12.6 9.1 49 5 45 305 7.2 0.1 7.9 6.9 08/16/2005 06:50:00 11 0.6 13 9.5 10.8 0.6 12.6 9.1 52 4 49 305 7.1 0.1 7.7 6.9 08/16/2005 07:00:00 11 0.6 13 9.1 10.8 0.6 12.2 9.1 50 3 47 305 7 0.1 7.7 6.9 08/16/2005 07:10:00 11.4 0.6 13 9.9 11.3 0.6 12.6 9.9 47 3 47 305 7 0.1 7.7 6.9 08/16/2005 07:20:00 12.3 0.6 13.7 10.7 12.1 0.6 13.3 10.3 42 3 40 305 6.8 0.2 7.4 6.4 08/16/2005 07:30:00 12.2 0.5 13.3 11.1 12.1 0.5 13.3 11.1 46 2 46 305 6.6 0.1 7.2 6.4 08/16/2005 07:40:00 11.9 0.5 13 10.7 11.8 0.5 13 9.9 47 3 42 305 6.5 0 6.9 6.4 08/16/2005 07:50:00 11.6 0.6 13 10.3 11.4 0.6 13 9.9 49 3 46 305 6.7 0 7.2 6.4 08/16/2005 08:00:00 12.1 0.5 13.3 10.7 12 0.5 13.3 10.3 47 3 44 305 6.8 0 7.2 6.4 08/16/2005 08:10:00 12.4 0.7 14.1 11.1 12.2 0.7 14.1 10.7 45 3 44 305 6.7 0.1 7.2 6.4 08/16/2005 08:20:00 13.1 0.9 14.9 11.5 12.8 0.9 14.5 10.3 51 3 48 305 6.9 0 7.4 6.7 08/16/2005 08:30:00 13 0.6 14.5 11.5 12.8 0.6 14.5 11.5 52 3 52 305 6.9 0 7.2 6.9 08/16/2005 08:40:00 12.6 0.5 14.1 11.5 12.4 0.5 14.1 11.1 47 3 42 305 6.8 0 7.2 6.9 08/16/2005 08:50:00 13.1 0.8 15.3 11.8 13 0.7 15.3 11.1 45 2 44 305 7 0 7.2 7.2 08/16/2005 09:00:00 13.7 0.6 15.6 12.6 13.6 0.6 15.3 12.2 46 3 43 305 7.1 0 7.4 7.2 08/16/2005 09:10:00 13.7 0.8 15.6 12.2 13.5 0.8 15.6 11.5 47 3 50 305 7.1 0 7.2 7.2 08/16/2005 09:20:00 13.4 0.6 14.9 11.8 13.1 0.7 14.9 11.1 49 3 44 305 7.1 0 7.4 6.9 08/16/2005 09:30:00 13.3 0.5 14.5 11.8 13.2 0.5 14.5 11.5 44 3 46 305 7.3 0 7.7 7.2 08/16/2005 09:40:00 13 0.5 14.5 11.8 13 0.5 14.5 11.8 41 2 38 305 7.4 0 7.7 7.4 08/16/2005 09:50:00 13.8 0.6 15.3 12.2 13.7 0.6 14.9 12.2 40 3 41 305 7.4 0 7.7 7.4 08/16/2005 10:00:00 13.6 0.8 15.6 11.5 13.5 0.8 16.1 11.1 42 3 46 305 7.3 0 7.4 7.2 08/16/2005 10:10:00 14.2 0.7 15.6 12.2 14.1 0.7 16.1 12.2 43 3 43 305 7.5 0 7.7 7.4 08/16/2005 10:20:00 13.7 0.8 15.6 11.8 13.7 0.7 15.6 11.8 45 3 38 305 7.6 0 7.7 7.7 08/16/2005 10:30:00 14 0.7 15.6 12.2 13.9 0.8 15.6 11.8 45 3 44 305 7.6 0 7.7 7.7 08/16/2005 10:40:00 14 0.6 15.3 12.2 13.8 0.6 15.6 12.2 41 3 38 305 7.6 0 7.7 7.4 08/16/2005 10:50:00 14.8 0.8 16.4 12.6 14.6 0.8 16.4 12.2 44 3 47 305 7.5 0 7.7 7.4 08/16/2005 11:00:00 14.6 0.8 16.8 12.2 14.5 0.9 16.8 11.8 45 3 45 305 7.6 0 7.9 7.7 08/16/2005 11:10:00 14.3 0.8 16.1 12.2 14.2 0.9 16.4 11.8 45 3 48 305 7.7 0 7.9 7.7 08/16/2005 11:20:00 14.3 0.8 16.1 11.5 14.1 0.9 16.1 11.8 44 3 47 305 7.8 0 7.9 7.7 08/16/2005 11:30:00 14.1 0.9 16.4 11.8 14 0.9 16.1 11.5 42 4 40 305 7.9 0 8.2 7.7 08/16/2005 11:40:00 13.7 0.7 15.3 12.2 13.6 0.8 15.3 11.8 46 3 44 305 7.9 0 8.2 7.7 08/16/2005 11:50:00 14.1 0.7 16.4 12.6 13.8 0.7 16.4 11.8 48 4 49 305 8 0 8.2 7.9 08/16/2005 12:00:00 14.7 0.7 16.4 13 14.5 0.8 16.4 12.2 48 3 51 305 8.2 0 8.4 7.9 08/16/2005 12:10:00 14.7 0.7 16.4 12.6 14.5 0.8 16.4 12.6 47 3 45 305 8.3 0 8.4 8.2 08/16/2005 12:20:00 13.9 0.8 15.6 11.5 13.7 0.9 15.3 11.1 48 4 51 305 8.4 0 8.7 8.2 08/16/2005 12:30:00 13.7 1 16.8 12.2 13.5 1 16.4 11.5 49 4 42 305 8.6 0 8.9 8.4 08/16/2005 12:40:00 14.3 0.9 16.1 11.8 14.1 0.9 16.1 11.5 48 4 48 305 8.4 0 8.7 8.2 08/16/2005 12:50:00 14.6 0.8 16.1 12.2 14.5 0.8 16.4 11.8 46 4 52 305 8.2 0 8.4 8.2 08/16/2005 13:00:00 13.5 0.7 15.6 11.8 13.3 0.8 15.6 11.5 48 4 49 305 8.1 0 8.4 7.9 08/16/2005 13:10:00 13.6 0.6 15.6 12.2 13.4 0.7 15.3 11.1 50 3 50 305 8.3 0 8.4 8.2 08/16/2005 13:20:00 13.8 0.6 15.6 11.8 13.7 0.6 15.3 11.5 49 3 43 305 8.4 0 8.7 8.2 08/16/2005 13:30:00 14.2 0.8 16.1 12.2 14 0.9 15.6 11.5 48 4 44 305 8.4 0.1 8.7 8.2 08/16/2005 13:40:00 14.5 0.6 15.6 13 14.4 0.7 16.1 11.8 47 3 43 305 8.1 0 8.2 7.9 08/16/2005 13:50:00 13.5 0.6 14.9 11.8 13.4 0.7 15.3 10.7 49 4 51 305 7.9 0 8.2 7.7 08/16/2005 14:00:00 13.4 0.8 16.1 11.1 13.3 0.8 15.6 10.7 47 3 46 305 8.2 0 8.4 7.9 08/16/2005 14:10:00 13.5 0.8 15.3 11.8 13.4 0.8 15.3 11.5 46 3 40 305 8.4 0 8.4 8.2 08/16/2005 14:20:00 13.7 0.7 15.3 11.5 13.5 0.7 15.6 11.5 45 3 42 305 8.2 0 8.4 8.2 08/16/2005 14:30:00 13.1 0.7 14.9 11.5 12.8 0.8 14.5 10.7 52 4 57 305 8.1 0 8.2 7.9 08/16/2005 14:40:00 12.8 0.7 14.1 11.1 12.5 0.8 14.1 9.9 54 3 53 305 8.2 0.1 8.4 7.9 08/16/2005 14:50:00 12.7 0.6 14.1 11.1 12.3 0.7 14.1 10.3 54 3 56 305 8.4 0.1 8.9 8.2 08/16/2005 15:00:00 12.4 0.7 14.1 10.7 12 0.7 14.1 9.9 51 4 56 305 8.6 0 8.9 8.4 08/16/2005 15:10:00 13.3 0.7 15.3 11.8 13 0.8 14.9 11.1 49 4 43 305 8.6 0.1 8.9 8.2 08/16/2005 15:20:00 13.9 0.7 15.6 12.2 13.6 0.8 15.6 11.8 50 4 47 305 8.2 0.1 8.7 7.9 08/16/2005 15:30:00 14.1 0.8 16.1 11.5 13.8 0.9 15.6 10.7 50 5 43 305 7.9 0 8.2 7.7 08/16/2005 15:40:00 12.9 0.8 14.9 11.1 12.6 0.9 14.9 10.3 51 4 55 305 8.1 0 8.2 7.9 08/16/2005 15:50:00 12.2 0.5 13.7 10.7 11.9 0.6 13.3 10.3 51 3 48 305 8.2 0.1 8.4 7.9 08/16/2005 16:00:00 12 0.6 13.3 10.7 11.8 0.6 13.3 9.5 48 3 47 305 8 0 8.4 7.7 08/16/2005 16:10:00 12.4 0.6 13.7 10.7 12 0.6 13.3 10.3 53 4 53 305 8.1 0 8.4 7.9 08/16/2005 16:20:00 13.1 0.7 14.9 11.5 12.7 0.8 14.5 11.1 49 4 48 305 7.8 0.1 8.2 7.4 08/16/2005 16:30:00 13.1 0.6 14.9 10.7 12.7 0.7 14.5 10.3 52 5 57 305 7.5 0 7.7 7.4 08/16/2005 16:40:00 12.5 0.8 14.5 10.7 12 0.8 14.1 9.5 55 3 57 305 7.6 0 7.9 7.4 08/16/2005 16:50:00 11.8 0.6 13.3 10.3 11.3 0.7 13 9.5 55 3 56 305 7.8 0.2 8.2 7.4 08/16/2005 17:00:00 11.7 0.6 13.3 9.9 11.1 0.7 13 9.1 55 3 61 305 7.7 0.1 8.2 7.4 08/16/2005 17:10:00 12 0.8 13.7 9.1 11.5 0.8 13.3 9.1 55 4 53 305 7.5 0 7.7 7.4 08/16/2005 17:20:00 11.4 0.6 12.6 9.9 11 0.6 12.6 9.5 54 4 58 305 7.2 0.1 7.7 7.2 08/16/2005 17:30:00 12 1 14.1 9.1 11.7 0.9 13.3 9.1 53 3 54 305 7 0 7.2 6.9 08/16/2005 17:40:00 12.7 0.7 14.5 9.9 12.3 0.8 14.1 9.5 59 3 63 305 7.1 0.1 7.4 6.9 08/16/2005 17:50:00 13.3 0.5 14.5 11.1 13 0.7 14.1 9.9 61 2 60 305 7.5 0 7.7 7.4 08/16/2005 18:00:00 12.6 0.5 13.7 11.1 12.4 0.5 13.7 10.7 59 2 58 305 7.3 0 7.4 7.2 08/16/2005 18:10:00 12.5 0.5 13.7 11.1 12.3 0.5 13.7 10.7 56 3 59 305 7.2 0 7.4 7.2 08/16/2005 18:20:00 10.4 0.8 12.2 8.4 10.3 0.8 13 8.4 54 4 59 305 6.8 0 7.2 6.7 08/16/2005 18:30:00 10.8 0.5 12.2 9.5 10.7 0.5 11.8 9.5 53 3 60 305 6.8 0 7.2 6.7 08/16/2005 18:40:00 10.6 0.5 11.8 8.8 10.5 0.5 11.8 8.8 53 3 52 305 6.8 0 7.2 6.7 08/16/2005 18:50:00 10.7 0.7 12.2 8.4 10.6 0.6 11.8 8.8 52 4 52 305 6.6 0 6.9 6.4 08/16/2005 19:00:00 11.8 0.4 12.6 10.7 11.6 0.4 12.6 9.5 55 2 57 305 6.5 0 6.7 6.4 08/16/2005 19:10:00 11.7 0.4 12.6 10.7 11.5 0.5 12.6 10.3 56 2 53 305 6.3 0 6.4 6.1 08/16/2005 19:20:00 11.1 0.5 12.2 9.9 10.9 0.5 12.2 9.5 55 2 54 305 6.3 0 6.4 6.1 08/16/2005 19:30:00 10.3 0.4 11.5 9.1 10.2 0.3 11.1 9.1 52 2 48 305 6.3 0 6.4 6.1 08/16/2005 19:40:00 10.4 0.4 11.5 9.1 10.3 0.4 11.8 8.8 52 3 50 305 6.4 0 6.9 6.1 08/16/2005 19:50:00 10.2 0.8 11.5 7.2 10.2 0.6 11.5 8.4 55 3 55 305 6.5 0 6.9 6.1 08/16/2005 20:00:00 10.6 0.5 11.8 8.4 10.4 0.5 11.5 9.1 53 2 53 305 6.4 0 6.9 6.1 08/16/2005 20:10:00 11 0.3 11.8 9.9 10.8 0.4 11.5 9.5 55 2 56 305 6.3 0 6.9 6.1 08/16/2005 20:20:00 10.6 0.4 11.5 9.5 10.5 0.4 11.8 9.5 55 2 54 305 6.3 0 6.9 6.1 08/16/2005 20:30:00 10.1 0.6 11.5 8.4 10 0.5 11.5 8.4 50 3 52 305 6.3 0 6.9 6.1 08/16/2005 20:40:00 10.3 0.6 11.5 8.4 10.2 0.6 11.1 8.8 53 3 54 305 6.3 0 6.7 6.1 08/16/2005 20:50:00 10.7 0.6 11.8 9.1 10.6 0.6 11.8 8.8 52 3 55 305 6.3 0 6.9 6.1 08/16/2005 21:00:00 10.5 0.4 11.5 9.5 10.4 0.4 11.5 9.1 54 3 59 305 6.3 0 6.9 6.1 08/16/2005 21:10:00 9.9 0.8 11.1 7.2 9.8 0.6 11.1 7.6 52 4 53 305 6.3 0 6.9 6.1 08/16/2005 21:20:00 8.2 0.6 9.9 6.8 8.3 0.6 9.9 6.1 53 5 59 305 6.1 0.1 6.7 5.9 08/16/2005 21:30:00 9.3 0.7 11.1 7.6 9.3 0.7 11.1 7.2 51 4 52 305 6.1 0.2 6.7 5.9 08/16/2005 21:40:00 9.6 0.5 11.1 8.4 9.6 0.6 11.5 8 52 3 57 305 6 0.1 6.7 5.6 08/16/2005 21:50:00 10.3 0.7 11.5 8 10.2 0.7 11.8 8 53 4 57 305 6 0.1 6.7 5.9 08/16/2005 22:00:00 11.5 0.4 12.2 10.3 11.3 0.4 12.6 9.9 55 2 56 305 6 0.1 6.7 5.9 08/16/2005 22:10:00 11.7 0.4 12.2 10.3 11.4 0.5 12.6 9.9 56 3 57 305 6 0 6.4 5.9 08/16/2005 22:20:00 11.9 0.4 12.6 10.3 11.7 0.4 12.6 10.3 56 2 58 305 6.1 0.1 6.4 5.9 08/16/2005 22:30:00 11.8 0.3 12.6 11.1 11.6 0.3 12.6 10.7 55 2 54 305 6 0 6.4 5.9 08/16/2005 22:40:00 12.2 0.4 13 10.7 12 0.5 13 10.7 57 2 56 305 6 0 6.4 5.9 08/16/2005 22:50:00 11.7 0.3 12.6 10.7 11.6 0.3 12.2 10.7 56 2 56 305 6 0 6.1 5.9 08/16/2005 23:00:00 11.1 0.6 12.2 9.9 10.9 0.5 12.2 9.5 54 2 51 305 5.8 0 6.1 5.6 08/16/2005 23:10:00 11 0.5 12.6 9.9 10.8 0.5 12.2 9.5 53 3 53 305 5.8 0 6.1 5.4 08/16/2005 23:20:00 10.6 0.6 11.8 8.8 10.3 0.6 11.8 8.4 51 3 51 305 5.4 0 5.9 5.4 08/16/2005 23:30:00 10 0.5 11.5 8.8 9.8 0.5 11.1 7.6 53 3 48 305 5.5 0.1 6.1 5.4 08/16/2005 23:40:00 10.8 0.6 11.8 8.8 10.6 0.6 11.8 8.8 54 3 54 305 5.6 0 6.1 5.4 08/16/2005 23:50:00 10.6 0.4 11.5 9.5 10.6 0.4 11.5 9.5 56 3 59 305 5.8 0 6.1 5.6 08/17/2005 00:00:00 10 0.5 11.1 8.8 10 0.5 11.1 8.8 53 2 52 305 5.8 0 5.9 5.6 08/17/2005 00:10:00 9.9 0.4 11.1 8.8 9.8 0.4 10.7 8.8 51 3 54 305 5.6 0.1 5.9 5.4 08/17/2005 00:20:00 9.5 0.5 10.7 8.8 9.3 0.5 10.7 8 54 3 47 305 5.4 0 6.1 5.4 08/17/2005 00:30:00 9 0.4 9.9 8 9.2 0.3 10.3 8.4 53 3 51 305 6 0 6.4 5.9 08/17/2005 00:40:00 8.7 0.5 9.9 7.6 8.5 0.6 10.3 6.5 52 4 50 305 5.8 0.1 6.4 5.6 08/17/2005 00:50:00 8.8 0.3 9.5 8 8.8 0.4 9.9 8 56 3 54 305 5.8 0.1 6.4 5.6 08/17/2005 01:00:00 8.2 0.5 9.5 6.8 8 0.5 9.1 6.5 56 3 55 305 5.8 0.1 6.4 5.4 08/17/2005 01:10:00 8.2 0.4 9.1 7.2 7.9 0.4 8.8 6.8 53 3 50 305 5.5 0 5.9 5.4 08/17/2005 01:20:00 7.6 0.4 8.8 6.5 7.5 0.5 8.8 6.1 56 4 62 305 5.7 0.2 6.4 5.4 08/17/2005 01:30:00 8.4 0.5 9.5 7.2 8.3 0.6 9.5 6.8 56 3 61 305 5.9 0 6.4 5.6 08/17/2005 01:40:00 8.7 0.6 9.9 7.6 8.4 0.7 9.9 6.5 55 3 52 305 5.5 0 6.1 5.4 08/17/2005 01:50:00 8.6 0.5 9.9 7.2 8.4 0.6 9.9 7.2 59 3 59 305 5.8 0.2 6.4 5.4 08/17/2005 02:00:00 8.8 0.5 9.9 7.2 8.6 0.6 9.9 6.8 60 3 61 305 5.8 0.1 6.1 5.4 08/17/2005 02:10:00 8.4 0.5 9.5 7.2 8.2 0.5 9.5 6.8 61 3 58 305 5.9 0 6.4 5.9 08/17/2005 02:20:00 7.9 0.6 9.1 6.1 7.7 0.6 9.1 5.7 60 4 66 305 5.8 0.1 6.4 5.4 08/17/2005 02:30:00 7.7 0.4 8.8 6.8 7.6 0.4 8.4 6.5 53 2 53 305 5.3 0 5.9 5.2 08/17/2005 02:40:00 8 0.3 8.8 7.2 8 0.3 8.8 7.2 49 3 53 305 5.3 0 5.4 5.2 08/17/2005 02:50:00 7.9 0.3 8.8 7.2 7.9 0.3 8.8 7.2 49 2 51 305 5.3 0 5.6 5.4 08/17/2005 03:00:00 8 0.3 8.8 7.2 8.1 0.3 8.8 7.2 47 2 46 305 5.5 0 5.6 5.4 08/17/2005 03:10:00 8.8 0.5 9.5 7.6 8.8 0.6 9.9 7.2 44 3 42 305 5.5 0 5.6 5.4 08/17/2005 03:20:00 8.3 0.5 9.5 6.5 8.2 0.6 9.1 6.1 51 3 51 305 5.5 0 5.6 5.4 08/17/2005 03:30:00 8 0.4 9.1 7.2 7.8 0.4 8.8 6.8 53 3 53 305 5.4 0 5.6 5.4 08/17/2005 03:40:00 8.4 0.4 9.5 7.2 8.2 0.4 9.1 6.8 55 3 53 305 5.7 0 5.9 5.4 08/17/2005 03:50:00 9.1 0.3 9.9 8 9 0.4 9.9 8 55 2 54 305 6 0 6.1 5.9 08/17/2005 04:00:00 8.9 0.4 9.9 8 8.9 0.4 9.9 7.2 54 3 56 305 6 0 6.1 5.9 08/17/2005 04:10:00 9.1 0.4 9.9 8 9 0.5 9.9 7.6 55 3 53 305 6.1 0 6.1 5.9 08/17/2005 04:20:00 9.2 0.4 9.9 8 9.2 0.4 10.3 8.4 53 4 56 305 6.2 0 6.4 6.1 08/17/2005 04:30:00 8.6 0.6 9.9 6.8 8.9 0.5 10.3 7.6 51 5 56 305 6.3 0 6.4 6.1 08/17/2005 04:40:00 8.6 0.6 9.5 6.1 8.7 0.6 9.9 6.5 53 4 46 305 6.3 0 6.4 6.1 08/17/2005 04:50:00 8.4 0.5 9.5 6.5 8.3 0.6 9.5 6.5 55 3 53 305 6.4 0 6.9 6.1 08/17/2005 05:00:00 8.4 0.3 9.1 7.2 8.4 0.4 9.1 6.8 53 2 50 305 6.4 0 6.9 6.1 08/17/2005 05:10:00 8.5 0.4 9.5 7.2 8.7 0.4 9.5 7.6 51 3 52 305 6.4 0 6.9 6.1 08/17/2005 05:20:00 9 0.3 9.9 8.4 9 0.3 9.9 8.4 52 2 52 305 6.4 0 6.9 6.1 08/17/2005 05:30:00 8.8 0.3 9.9 8 8.9 0.3 9.5 8 50 3 53 305 6.4 0 6.9 6.1 08/17/2005 05:40:00 8.8 0.3 10.3 8 9 0.4 9.9 8 50 4 44 305 6.5 0 7.2 6.4 08/17/2005 05:50:00 8.2 0.6 10.3 6.8 8.5 0.5 10.7 7.2 49 4 50 305 6.6 0 7.2 6.4 08/17/2005 06:00:00 7.6 0.5 9.1 6.1 7.9 0.5 9.1 6.5 50 5 46 305 6.6 0.1 7.2 6.4 08/17/2005 06:10:00 8.1 0.5 9.5 6.8 8.2 0.5 9.9 6.5 50 5 51 305 6.7 0.1 7.2 6.4 08/17/2005 06:20:00 8.1 0.5 9.5 6.8 8.2 0.5 9.5 6.8 51 5 61 305 6.8 0.1 7.4 6.7 08/17/2005 06:30:00 8.3 0.6 9.5 6.8 8.5 0.6 9.9 6.8 52 5 54 305 7 0 7.4 6.9 08/17/2005 06:40:00 8.4 0.4 9.5 7.2 8.5 0.4 9.5 7.6 53 3 54 305 7 0 7.4 6.9 08/17/2005 06:50:00 8.1 0.4 9.5 7.2 8.2 0.4 9.1 7.2 54 4 48 305 7 0 7.4 6.9 08/17/2005 07:00:00 7.7 0.5 8.8 6.5 7.9 0.5 9.5 6.5 53 4 50 305 7 0 7.4 6.9 08/17/2005 07:10:00 6.8 0.5 8 5.3 6.9 0.5 8 5.3 53 5 48 305 7 0 7.4 6.9 08/17/2005 07:20:00 6.4 0.4 7.6 5.3 6.6 0.4 8 5.7 48 5 60 305 6.8 0 7.2 6.7 08/17/2005 07:30:00 7.1 0.6 8.4 5.3 7.2 0.6 8.4 5.3 46 5 48 305 6.9 0 7.2 6.7 08/17/2005 07:40:00 8.2 0.4 9.1 6.8 8.2 0.5 9.1 6.8 40 3 39 305 6.7 0 6.9 6.4 08/17/2005 07:50:00 8.3 0.4 9.5 7.6 8.4 0.4 9.5 7.2 43 3 37 305 6.8 0 6.9 6.7 08/17/2005 08:00:00 7.9 0.5 9.1 6.5 7.9 0.5 9.1 6.8 48 3 48 305 6.8 0 6.9 6.7 08/17/2005 08:10:00 7.2 0.4 8.4 6.1 7.2 0.4 8 6.1 49 4 46 305 6.9 0 7.2 6.9 08/17/2005 08:20:00 7 0.4 8 5.7 7 0.4 8 6.1 52 4 48 305 7 0 7.2 6.9 08/17/2005 08:30:00 7.2 0.6 8.4 5.7 7.1 0.6 8.4 5.7 50 4 47 305 7 0 7.2 6.9 08/17/2005 08:40:00 7.8 0.4 8.8 6.8 7.6 0.4 8.8 6.8 49 2 51 305 7.1 0 7.4 7.2 08/17/2005 08:50:00 8 0.3 8.8 7.2 8 0.3 8.8 7.2 44 2 46 305 7.3 0 7.7 7.2 08/17/2005 09:00:00 7.5 0.4 8.4 6.5 7.4 0.5 8.4 6.1 46 3 44 305 7.5 0 7.7 7.4 08/17/2005 09:10:00 7.1 0.3 8 6.5 6.9 0.3 8 6.1 49 2 52 305 7.3 0 7.7 7.4 08/17/2005 09:20:00 6.8 0.3 7.6 6.1 6.6 0.3 7.2 5.7 51 3 46 305 7.3 0 7.4 7.4 08/17/2005 09:30:00 6.7 0.3 7.6 5.7 6.5 0.3 7.2 5.3 51 3 46 305 7.5 0 7.7 7.4 08/17/2005 09:40:00 6.7 0.4 7.6 5.7 6.6 0.4 7.6 5.7 52 3 52 305 7.6 0 7.9 7.7 08/17/2005 09:50:00 7 0.4 8 5.7 6.7 0.4 7.6 5.7 50 3 50 305 7.6 0 8.2 7.7 08/17/2005 10:00:00 6.7 0.5 8 5.7 6.6 0.5 8 5.7 49 3 48 305 7.7 0 8.2 7.7 08/17/2005 10:10:00 7.2 0.4 8 6.1 7.1 0.4 8 6.1 48 3 48 305 7.8 0 8.2 7.7 08/17/2005 10:20:00 7.2 0.4 8 6.5 7.2 0.4 8 6.1 45 3 42 305 7.9 0 8.2 7.7 08/17/2005 10:30:00 6.8 0.4 7.6 5.7 6.7 0.4 7.6 5.7 42 4 33 305 7.7 0 8.2 7.7 08/17/2005 10:40:00 6.8 0.3 7.6 6.1 7 0.3 7.6 6.1 36 2 39 305 8 0 8.2 7.7 08/17/2005 10:50:00 6.9 0.3 7.6 6.1 7 0.3 7.6 5.3 35 3 33 305 8 0 8.2 7.9 08/17/2005 11:00:00 6.5 0.4 7.2 5.7 6.6 0.4 7.6 5.7 32 4 27 305 8 0.1 8.4 7.7 08/17/2005 11:10:00 6.5 0.4 7.2 5.7 6.5 0.4 7.2 5.3 42 4 39 305 8.2 0.1 8.4 8.2 08/17/2005 11:20:00 6.5 0.4 7.6 5.7 6.4 0.4 7.2 5.3 47 4 47 305 8.3 0 8.7 8.2 08/17/2005 11:30:00 6.3 0.3 7.2 5.7 6.3 0.4 7.2 5.3 40 5 41 305 8.4 0 8.4 8.2 08/17/2005 11:40:00 6.2 0.5 7.2 4.9 6.3 0.4 7.2 4.9 33 3 29 305 8.4 0 8.7 8.2 08/17/2005 11:50:00 5.7 0.3 6.5 4.6 5.8 0.4 6.8 4.2 46 6 36 305 8.4 0.1 8.9 8.2 08/17/2005 12:00:00 5.6 0.4 6.5 4.2 5.4 0.5 6.5 4.2 54 5 56 305 8.6 0 8.7 8.4 08/17/2005 12:10:00 5.3 0.3 6.1 4.6 5.4 0.4 6.5 4.6 48 6 60 305 8.4 0 8.7 8.2 08/17/2005 12:20:00 5.2 0.4 6.5 4.2 5.4 0.5 6.8 4.2 29 9 23 305 8.5 0 8.7 8.4 08/17/2005 12:30:00 5.2 0.5 6.5 4.2 5.5 0.5 6.5 4.6 29 6 30 305 8.6 0 8.9 8.4 08/17/2005 12:40:00 5 0.5 6.8 3.8 5.1 0.6 6.5 3.4 24 8 29 305 8.5 0 8.7 8.4 08/17/2005 12:50:00 5.1 0.5 6.1 3.8 5.3 0.5 6.5 4.2 22 6 25 305 8.4 0 8.4 8.2 08/17/2005 13:00:00 5.2 0.4 6.1 4.2 5.4 0.4 6.5 4.6 20 8 16 305 8.4 0 8.4 8.2 08/17/2005 13:10:00 5.3 0.6 6.8 3.8 5.5 0.7 6.8 3.8 28 9 30 305 8.5 0 8.7 8.2 08/17/2005 13:20:00 5.4 0.6 6.1 3.8 5.6 0.6 6.5 4.2 24 5 25 305 8.4 0 8.7 8.2 08/17/2005 13:30:00 5 0.5 6.5 3.8 5.2 0.5 6.5 3.8 30 4 29 305 8.4 0 8.7 8.2 08/17/2005 13:40:00 5.4 0.5 6.8 4.2 5.6 0.5 6.8 3.8 33 4 32 305 8.8 0 8.9 8.4 08/17/2005 13:50:00 5.5 0.5 6.8 4.6 5.6 0.5 6.8 4.6 29 4 23 305 8.7 0 8.9 8.7 08/17/2005 14:00:00 5.2 0.5 6.5 4.2 5.2 0.5 6.5 3.8 34 6 35 305 8.6 0 8.9 8.2 08/17/2005 14:10:00 5.4 0.6 6.8 3.4 5.5 0.7 6.8 3.8 30 5 26 305 8.6 0 8.7 8.4 08/17/2005 14:20:00 5.5 0.5 6.5 3.8 5.6 0.5 6.5 3.8 33 6 18 305 8.6 0 8.9 8.4 08/17/2005 14:30:00 5.5 0.4 6.5 4.2 5.5 0.5 6.8 3.8 41 10 48 305 8.6 0 8.9 8.4 08/17/2005 14:40:00 5.4 0.5 6.8 4.2 5.5 0.5 6.5 4.2 48 6 49 305 8.4 0 8.7 8.2 08/17/2005 14:50:00 4.8 0.5 6.1 3.8 4.8 0.6 6.1 3.4 44 8 48 305 8.4 0 8.7 8.2 08/17/2005 15:00:00 4.9 0.5 6.1 3 4.8 0.5 6.1 3 40 8 37 305 8.5 0 8.9 8.2 08/17/2005 15:10:00 4.4 0.5 5.7 3.4 4.5 0.5 6.1 3.4 35 6 39 305 8.6 0.1 8.9 8.4 08/17/2005 15:20:00 4.8 0.5 6.1 3.4 4.8 0.6 6.1 3 27 4 29 305 8.9 0 9.2 8.7 08/17/2005 15:30:00 5.3 0.4 6.5 3.8 5.4 0.5 6.5 3.8 20 4 21 305 9.1 0 9.5 8.9 08/17/2005 15:40:00 5.4 0.5 6.5 4.2 5.3 0.6 6.5 4.2 26 5 24 305 9.2 0 9.5 9.2 08/17/2005 15:50:00 5.2 0.3 5.7 4.2 5.2 0.4 6.1 4.2 27 3 27 305 9.2 0 9.5 9.2 08/17/2005 16:00:00 5 0.3 5.7 4.2 5 0.3 5.7 4.2 27 3 25 305 9.1 0 9.5 8.9 08/17/2005 16:10:00 5.1 0.2 5.7 4.6 5.1 0.3 5.7 3.8 24 3 29 305 9.2 0 9.5 9.2 08/17/2005 16:20:00 5.1 0.2 5.7 4.6 5.2 0.3 5.7 4.2 21 2 22 305 9.1 0 9.5 8.9 08/17/2005 16:30:00 5 0.3 5.7 3.8 4.9 0.4 5.7 3.8 23 4 25 305 9.1 0 9.5 8.9 08/17/2005 16:40:00 4.8 0.3 5.3 4.2 4.7 0.3 5.7 3.8 29 3 36 305 9.1 0 9.2 8.9 08/17/2005 16:50:00 4.7 0.2 5.7 4.2 4.8 0.3 5.7 4.2 25 3 23 305 9 0 9.2 8.9 08/17/2005 17:00:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.8 23 3 32 305 9.1 0 9.2 8.9 08/17/2005 17:10:00 4.5 0.2 5.3 4.2 4.6 0.2 4.9 3.8 20 2 18 305 9 0 9.2 8.9 08/17/2005 17:20:00 4.4 0.3 4.9 3.8 4.4 0.4 5.3 3.4 21 3 20 305 9.1 0 9.2 8.9 08/17/2005 17:30:00 4.1 0.3 4.9 3.4 4.2 0.3 4.9 3.4 25 6 18 305 9.1 0 9.2 9.2 08/17/2005 17:40:00 4 0.3 4.6 3.4 4 0.3 4.6 3 29 3 27 305 9.1 0 9.2 8.9 08/17/2005 17:50:00 4 0.2 4.6 3.4 4 0.3 4.6 3 33 3 33 305 8.9 0 9.2 8.9 08/17/2005 18:00:00 3.7 0.3 4.2 3 3.8 0.3 4.6 2.6 28 4 31 305 8.8 0 9.2 8.9 08/17/2005 18:10:00 3.5 0.3 4.2 2.3 3.5 0.4 4.2 2.6 24 4 27 305 8.9 0 9.2 8.9 08/17/2005 18:20:00 3.6 0.2 4.2 3 3.6 0.3 4.2 2.6 17 2 18 305 8.6 0.1 9.2 8.4 08/17/2005 18:30:00 3.7 0.2 4.2 3 3.7 0.3 4.2 2.6 13 3 13 305 8.9 0 9.2 8.9 08/17/2005 18:40:00 3.6 0.4 4.2 1.9 3.6 0.5 4.6 2.3 4 5 2 305 8.9 0 9.2 8.9 08/17/2005 18:50:00 4 0.2 4.6 3.4 4.1 0.3 4.9 3 358 2 355 305 8.9 0 9.2 8.9 08/17/2005 19:00:00 4.2 0.2 4.9 3.4 4.4 0.3 4.9 3.4 358 2 357 305 9 0 9.2 8.9 08/17/2005 19:10:00 4.3 0.2 4.9 3.8 4.5 0.3 5.3 3.4 351 4 352 305 9.1 0 9.2 8.9 08/17/2005 19:20:00 4.4 0.3 5.3 3.4 4.5 0.5 5.7 3 341 5 338 305 8.9 0 9.2 8.7 08/17/2005 19:30:00 4.5 0.5 5.7 3 4.7 0.5 5.7 3.4 337 7 334 305 8.7 0 8.9 8.4 08/17/2005 19:40:00 4.4 0.5 5.3 3 4.6 0.5 5.7 3.4 329 13 344 305 8.6 0 8.7 8.4 08/17/2005 19:50:00 3.9 0.6 5.3 2.6 4 0.7 5.7 2.6 321 8 317 305 8.3 0 8.4 8.2 08/17/2005 20:00:00 4.4 0.6 6.1 3 4.4 0.6 6.5 2.6 323 12 324 305 8.3 0 8.4 8.2 08/17/2005 20:10:00 4.3 0.5 5.7 3 4.3 0.6 5.7 2.6 315 7 315 305 8.3 0 8.4 8.2 08/17/2005 20:20:00 4.2 0.6 5.7 3 4.2 0.6 5.7 2.6 313 9 305 305 8.4 0 8.4 8.2 08/17/2005 20:30:00 4.4 0.5 5.7 3 4.5 0.5 5.7 3 309 7 311 305 8.4 0 8.4 8.2 08/17/2005 20:40:00 4 0.5 5.3 2.3 4.1 0.5 5.3 2.6 307 18 302 305 8.2 0 8.4 8.2 08/17/2005 20:50:00 3.9 0.6 5.3 2.6 4 0.6 5.3 2.6 302 9 306 305 8.4 0 8.4 8.2 08/17/2005 21:00:00 3 0.6 4.2 1.5 3.1 0.5 4.6 1.9 298 8 305 305 8.3 0 8.4 8.2 08/17/2005 21:10:00 3.4 0.6 4.9 2.3 3.5 0.5 4.9 2.3 291 11 287 305 8.5 0 8.7 8.4 08/17/2005 21:20:00 2.9 0.7 4.6 1.5 3 0.6 4.6 1.1 297 11 292 305 8.5 0 8.7 8.4 08/17/2005 21:30:00 3 0.5 4.2 1.9 3.1 0.5 4.6 1.5 294 12 294 305 8.5 0 8.7 8.4 08/17/2005 21:40:00 2.8 0.8 4.6 0.7 2.7 0.7 4.2 1.1 280 16 283 305 8.4 0 8.4 8.4 08/17/2005 21:50:00 2.3 0.6 3.8 0.7 2.5 0.5 3.8 1.1 285 11 276 305 8.6 0 8.7 8.4 08/17/2005 22:00:00 1.9 0.7 3.4 0.4 2 0.6 3.4 0.4 282 13 266 305 8.6 0 8.7 8.4 08/17/2005 22:10:00 1.5 0.7 2.6 0.4 1.7 0.6 3 0.4 283 14 290 305 8.7 0 8.9 8.7 08/17/2005 22:20:00 1.5 0.8 3 0.4 1.6 0.6 3 0.4 274 13 268 305 8.8 0 8.9 8.7 08/17/2005 22:30:00 1.2 0.8 3 0.4 1.4 0.6 3 0.4 272 13 283 305 8.8 0 8.9 8.9 08/17/2005 22:40:00 1.8 0.8 3.4 0.4 1.8 0.7 3.4 0.4 274 11 288 305 8.9 0 8.9 8.9 08/17/2005 22:50:00 1.7 0.7 3 0.4 1.6 0.5 2.6 0.4 271 10 270 305 8.9 0 9.2 8.9 08/17/2005 23:00:00 1.4 0.6 2.6 0.4 1.4 0.4 2.3 0.4 265 12 261 305 8.9 0 9.2 8.9 08/17/2005 23:10:00 1.8 1 4.2 0.4 2.1 0.8 3.8 0.4 267 20 275 305 9.1 0 9.2 8.9 08/17/2005 23:20:00 2.8 0.6 4.2 0.7 2.8 0.5 4.2 1.5 296 8 305 305 9.1 0 9.2 8.9 08/17/2005 23:30:00 3.4 0.7 4.6 1.1 3.2 0.7 4.6 1.1 296 10 309 305 8.9 0 9.2 8.9 08/17/2005 23:40:00 3.4 0.8 4.9 1.5 3 1 4.6 0.4 299 12 303 305 8.8 0 8.9 8.7 08/17/2005 23:50:00 4.1 0.5 5.3 2.6 3.8 0.5 5.3 2.3 304 10 302 305 8.8 0 8.9 8.7 08/18/2005 00:00:00 4.8 0.5 6.1 3.4 4.5 0.6 6.1 3 304 7 312 305 8.7 0 9.2 8.7 08/18/2005 00:10:00 4.9 0.4 5.7 3.8 4.6 0.4 5.3 3 303 9 302 305 8.7 0 8.9 8.7 08/18/2005 00:20:00 4.8 0.5 5.7 3.8 4.7 0.5 5.7 3 300 7 300 305 8.8 0 8.9 8.7 08/18/2005 00:30:00 5.4 0.6 6.8 3.8 5.3 0.6 6.5 3.8 299 10 302 305 8.8 0 8.9 8.7 08/18/2005 00:40:00 5 0.5 6.5 3.8 5 0.5 6.5 3.4 297 7 290 305 8.8 0 8.9 8.7 08/18/2005 00:50:00 4.9 0.5 6.1 3 4.8 0.6 6.1 3.4 305 12 306 305 8.7 0 8.9 8.4 08/18/2005 01:00:00 4.9 0.5 6.1 3.8 4.9 0.5 6.1 3.8 303 13 303 305 8.6 0 8.7 8.4 08/18/2005 01:10:00 4.7 0.5 5.7 3.4 4.6 0.6 6.1 3.4 299 11 300 305 8.6 0 8.7 8.4 08/18/2005 01:20:00 3.9 0.8 5.3 1.9 3.8 0.8 5.3 1.9 300 11 300 305 8.6 0 8.7 8.4 08/18/2005 01:30:00 3.6 1 5.7 1.9 3.5 1 6.1 1.9 296 8 292 305 8.6 0 8.7 8.4 08/18/2005 01:40:00 4.4 0.5 6.1 2.6 4.3 0.5 6.1 2.6 289 7 298 305 8.6 0 8.7 8.4 08/18/2005 01:50:00 5 0.8 6.1 2.6 4.8 0.7 5.7 3 303 10 298 305 8.6 0 8.7 8.4 08/18/2005 02:00:00 4.9 0.5 6.1 3 4.9 0.6 6.1 3.4 305 12 302 305 8.6 0 8.7 8.4 08/18/2005 02:10:00 4.7 0.5 5.7 3.4 4.7 0.5 5.7 3.4 298 13 288 305 8.4 0 8.4 8.2 08/18/2005 02:20:00 4.2 0.6 5.3 2.3 4.2 0.6 5.3 2.3 305 8 331 305 8.4 0 8.4 8.2 08/18/2005 02:30:00 3.9 0.5 4.9 2.6 3.9 0.5 4.9 2.6 299 9 289 305 8.4 0 8.4 8.2 08/18/2005 02:40:00 3.8 0.6 5.3 2.3 3.8 0.6 4.9 2.6 301 9 305 305 8.3 0 8.4 8.2 08/18/2005 02:50:00 2.4 0.8 4.2 0.4 2.6 0.8 4.2 0.4 301 15 305 305 8.1 0 8.2 7.9 08/18/2005 03:00:00 3.2 0.8 4.9 1.5 3.3 0.8 5.3 1.5 306 12 310 305 8 0 8.2 7.9 08/18/2005 03:10:00 1.4 0.9 3.8 0.4 1.7 0.7 4.2 0.7 306 22 299 305 7.9 0 8.2 7.9 08/18/2005 03:20:00 2.2 0.6 3.8 0.7 2.4 0.5 3.8 1.1 295 17 296 305 8.1 0 8.2 7.9 08/18/2005 03:30:00 2.3 0.7 4.6 0.7 2.1 0.5 3.8 1.1 269 13 265 305 8 0 8.2 7.9 08/18/2005 03:40:00 1.6 0.9 3.8 0.4 1.8 0.6 3.4 0.4 278 18 259 305 8 0 8.2 7.9 08/18/2005 03:50:00 3.1 0.5 4.2 1.9 2.8 0.4 4.2 1.9 254 9 254 305 7.7 0 7.9 7.7 08/18/2005 04:00:00 2.8 0.4 3.8 1.5 2.4 0.5 3.8 1.1 261 10 275 305 7.6 0 7.7 7.4 08/18/2005 04:10:00 2.8 0.5 3.8 0.7 2.3 0.5 3.8 0.7 275 11 276 305 7.6 0 7.7 7.7 08/18/2005 04:20:00 2.5 0.4 3.4 1.5 2.2 0.5 3.4 1.1 271 11 257 305 7.6 0 7.7 7.7 08/18/2005 04:30:00 3.2 0.5 4.2 2.3 2.7 0.5 4.2 1.5 260 8 255 305 7.7 0 7.9 7.7 08/18/2005 04:40:00 3.1 0.4 4.2 1.9 2.6 0.4 3.4 1.5 263 10 268 305 7.7 0 7.7 7.7 08/18/2005 04:50:00 2.9 0.4 4.2 1.9 2.6 0.5 3.8 1.1 275 11 275 305 7.7 0 7.9 7.7 08/18/2005 05:00:00 2.7 0.5 4.2 1.9 2.3 0.5 3.4 1.1 259 8 242 305 7.7 0 7.9 7.7 08/18/2005 05:10:00 3.1 0.4 4.2 1.9 2.6 0.5 3.8 1.5 276 10 280 305 7.7 0 7.9 7.7 08/18/2005 05:20:00 2.6 0.4 3.8 1.5 2.6 0.3 3.4 1.9 296 8 281 305 7.7 0 7.7 7.7 08/18/2005 05:30:00 2.7 0.8 4.6 1.1 2.6 0.8 4.6 1.1 290 8 297 305 7.7 0 7.9 7.7 08/18/2005 05:40:00 3 0.5 4.2 1.5 2.7 0.6 4.2 1.5 278 13 291 305 7.6 0 7.9 7.7 08/18/2005 05:50:00 2.9 0.5 3.8 1.5 2.5 0.5 3.8 1.1 266 12 284 305 7.8 0 7.9 7.7 08/18/2005 06:00:00 3.1 0.4 3.8 1.9 2.5 0.4 3.4 1.1 263 7 261 305 7.7 0 7.9 7.7 08/18/2005 06:10:00 2.6 0.4 3.8 1.5 2.2 0.5 3.4 1.1 259 9 250 305 7.6 0 7.7 7.7 08/18/2005 06:20:00 2.6 0.5 3.8 1.5 2.3 0.6 3.8 1.1 259 9 251 305 7.5 0 7.7 7.4 08/18/2005 06:30:00 2.7 0.5 3.8 1.5 2.5 0.6 3.8 1.1 279 8 279 305 7.5 0 7.7 7.4 08/18/2005 06:40:00 3 0.4 3.8 2.3 2.9 0.3 3.8 2.3 294 10 296 305 7.5 0 7.7 7.4 08/18/2005 06:50:00 1.9 0.9 3.8 0.4 1.6 0.7 3.4 0.4 261 10 287 305 7.5 0 7.7 7.4 08/18/2005 07:00:00 2.8 0.7 4.6 1.1 2.4 0.7 4.2 0.7 261 9 261 305 7.7 0 7.9 7.7 08/18/2005 07:10:00 2.3 0.4 3.4 1.1 2.1 0.4 3.4 1.1 256 11 252 305 7.6 0 7.7 7.7 08/18/2005 07:20:00 2.6 0.4 3.8 1.5 2.3 0.5 3.4 1.1 254 8 248 305 7.6 0 7.7 7.7 08/18/2005 07:30:00 2.7 0.5 3.8 1.1 2.6 0.5 3.8 1.5 249 8 247 305 7.6 0 7.7 7.7 08/18/2005 07:40:00 2 0.4 3 1.1 1.9 0.4 2.6 1.1 244 12 250 305 7.6 0 7.7 7.7 08/18/2005 07:50:00 1.9 0.5 2.6 0.7 1.8 0.5 3 0.4 255 11 245 305 7.5 0 7.7 7.4 08/18/2005 08:00:00 1.4 0.6 3 0.4 1.6 0.4 2.6 0.7 240 12 250 305 7.5 0 7.7 7.4 08/18/2005 08:10:00 1.7 0.6 2.6 0.4 1.7 0.5 2.6 0.4 275 24 288 305 7.5 0 7.7 7.4 08/18/2005 08:20:00 2.1 0.6 3.4 0.4 2.1 0.6 3.4 0.7 246 15 232 305 7.4 0 7.7 7.4 08/18/2005 08:30:00 2.4 0.4 3.8 1.1 2.4 0.4 3.4 1.5 238 9 250 305 7.3 0 7.4 7.2 08/18/2005 08:40:00 2.6 0.6 4.2 1.5 2.5 0.5 3.8 1.5 243 8 232 305 7.2 0 7.7 7.2 08/18/2005 08:50:00 2 0.7 3.8 0.4 2 0.6 3.8 0.7 232 17 244 305 7.2 0 7.4 7.2 08/18/2005 09:00:00 2.3 0.5 3.8 0.7 2.2 0.5 3.4 1.1 234 12 223 305 7.4 0 7.7 7.2 08/18/2005 09:10:00 2.8 0.5 4.6 1.5 2.7 0.5 3.8 1.1 248 12 266 305 7.4 0 7.7 7.2 08/18/2005 09:20:00 2.3 0.7 4.2 0.7 2.2 0.6 3.4 0.4 251 11 246 305 7.2 0 7.4 7.2 08/18/2005 09:30:00 2.8 0.5 3.8 0.7 2.6 0.4 3.8 1.1 245 10 257 305 7.2 0 7.4 7.2 08/18/2005 09:40:00 2.5 0.4 3.4 1.5 2.4 0.4 3.4 1.5 231 9 228 305 7.1 0 7.2 6.9 08/18/2005 09:50:00 2 0.4 3 0.7 1.9 0.5 3 1.1 248 12 227 305 7 0 7.2 6.9 08/18/2005 10:00:00 1.4 0.6 2.6 0.4 1.5 0.4 2.3 0.7 243 18 244 305 7.1 0 7.4 6.9 08/18/2005 10:10:00 1.5 0.8 3.4 0.4 1.8 0.6 3 0.4 220 21 252 305 7.4 0 7.7 7.2 08/18/2005 10:20:00 2 0.5 3 1.1 1.9 0.5 3 0.7 251 12 257 305 7.4 0 7.7 7.2 08/18/2005 10:30:00 1.2 0.5 2.3 0.4 1.4 0.4 2.6 0.4 261 13 256 305 7.4 0 7.7 7.2 08/18/2005 10:40:00 1.9 0.6 3 0.4 1.9 0.6 3 0.4 242 22 227 305 7.6 0 7.7 7.4 08/18/2005 10:50:00 2.5 0.4 3.8 1.5 2.4 0.5 3.8 1.5 246 18 247 305 7.5 0 7.7 7.4 08/18/2005 11:00:00 2 0.7 3 0.4 1.8 0.6 3.4 0.4 254 18 242 305 7.5 0 7.7 7.4 08/18/2005 11:10:00 2.4 0.4 3.4 1.5 2.2 0.4 3 1.1 268 11 259 305 7.3 0 7.7 7.2 08/18/2005 11:20:00 1.9 0.6 4.2 0.7 1.9 0.6 4.2 0.7 279 17 286 305 7.5 0 7.7 7.4 08/18/2005 11:30:00 1.8 0.5 3 0.4 1.8 0.5 3 0.7 233 21 222 305 7.9 0 7.9 7.7 08/18/2005 11:40:00 2.5 0.5 3.8 1.5 2.4 0.5 3.8 1.1 251 12 256 305 7.7 0 7.9 7.7 08/18/2005 11:50:00 2.3 0.5 3.4 0.7 2.2 0.5 3.4 0.7 248 10 250 305 7.5 0 7.7 7.4 08/18/2005 12:00:00 2.1 0.5 3.4 0.4 2.1 0.5 3 1.1 224 14 225 305 7.7 0 7.9 7.7 08/18/2005 12:10:00 2.3 0.5 4.2 1.1 2.3 0.5 3.8 1.1 223 11 221 305 7.9 0 8.2 7.7 08/18/2005 12:20:00 2.5 0.7 4.6 0.4 2.5 0.7 4.6 0.7 230 12 242 305 8 0 8.2 7.9 08/18/2005 12:30:00 3.1 0.4 4.2 1.9 2.9 0.6 4.2 1.1 254 8 251 305 8.1 0 8.2 7.9 08/18/2005 12:40:00 3 0.6 4.6 1.5 2.6 0.5 3.8 1.5 252 15 265 305 8 0 8.2 7.9 08/18/2005 12:50:00 2.6 1 4.2 0.4 2.4 0.9 4.2 0.4 251 15 251 305 8.2 0 8.4 8.2 08/18/2005 13:00:00 3 0.5 4.6 1.9 2.9 0.5 4.2 1.9 230 15 220 305 8.4 0 8.7 7.9 08/18/2005 13:10:00 2.8 0.6 4.2 1.1 2.6 0.6 4.2 1.1 239 14 231 305 8.6 0 8.9 8.4 08/18/2005 13:20:00 3.2 0.5 4.9 1.5 2.9 0.6 4.9 1.5 251 13 239 305 8.7 0 8.9 8.4 08/18/2005 13:30:00 3.2 0.6 4.6 1.5 2.9 0.6 4.6 1.1 256 12 254 305 8.6 0 8.9 8.4 08/18/2005 13:40:00 3.1 0.6 4.2 1.1 3 0.6 4.2 1.1 227 9 232 305 8.8 0 9.2 8.7 08/18/2005 13:50:00 2.8 0.4 3.8 1.5 2.8 0.4 3.8 1.5 230 9 237 305 8.9 0 9.2 8.9 08/18/2005 14:00:00 3.6 0.5 4.9 2.3 3.4 0.6 4.9 1.9 237 10 224 305 9.1 0 9.2 8.7 08/18/2005 14:10:00 3.3 0.6 4.9 1.9 3.2 0.6 4.9 1.5 231 9 231 305 8.9 0 9.2 8.9 08/18/2005 14:20:00 3.6 0.6 4.9 2.3 3.5 0.5 4.6 1.9 231 9 233 305 8.9 0 9.2 8.9 08/18/2005 14:30:00 3.6 0.6 5.3 1.9 3.5 0.6 5.3 2.3 232 8 235 305 9 0 9.2 8.9 08/18/2005 14:40:00 3.3 0.6 4.9 1.9 3.3 0.6 4.9 1.9 228 10 231 305 9.1 0 9.2 8.9 08/18/2005 14:50:00 3.6 0.5 4.6 2.3 3.4 0.5 4.9 2.3 235 12 234 305 9.3 0 9.5 9.2 08/18/2005 15:00:00 3.7 0.5 5.3 2.3 3.6 0.6 5.3 2.3 235 8 233 305 9.1 0 9.5 8.9 08/18/2005 15:10:00 3.8 0.5 5.3 2.3 3.7 0.5 4.9 2.6 234 8 238 305 9.1 0 9.2 8.9 08/18/2005 15:20:00 3.7 0.4 5.3 2.3 3.7 0.5 4.9 2.6 225 10 231 305 9.3 0 9.7 9.2 08/18/2005 15:30:00 4.2 0.5 4.9 2.6 4 0.5 4.9 2.6 235 11 228 305 9.3 0 9.7 9.2 08/18/2005 15:40:00 4.3 0.7 6.1 2.6 4.2 0.7 6.1 2.6 242 9 247 305 9.2 0 9.5 9.2 08/18/2005 15:50:00 4 0.6 5.7 2.6 3.9 0.6 5.7 2.3 242 10 253 305 9.1 0 9.2 8.9 08/18/2005 16:00:00 4.2 0.6 5.7 2.3 4 0.7 5.3 1.9 241 12 240 305 9.1 0 9.2 8.9 08/18/2005 16:10:00 4.1 0.8 6.1 2.3 4 0.7 5.7 2.3 242 9 245 305 9 0 9.2 8.9 08/18/2005 16:20:00 4.8 0.6 6.1 3 4.4 0.7 5.7 1.9 249 8 239 305 8.9 0 9.2 8.9 08/18/2005 16:30:00 4.4 0.5 6.1 3.4 4.2 0.5 5.7 3 234 8 241 305 8.9 0 9.2 8.9 08/18/2005 16:40:00 4.9 0.6 6.5 3.4 4.6 0.6 6.5 3 239 9 239 305 9 0 9.2 8.9 08/18/2005 16:50:00 4.6 0.6 6.1 3.4 4.4 0.7 6.5 2.6 248 8 248 305 9.2 0 9.2 9.2 08/18/2005 17:00:00 5.1 0.6 6.5 3 4.6 0.7 6.8 3 257 6 272 305 9.1 0 9.2 9.2 08/18/2005 17:10:00 5 0.7 6.8 3.4 4.7 0.7 6.1 3 242 8 252 305 9.1 0 9.2 8.9 08/18/2005 17:20:00 5.2 0.7 6.8 3.4 4.7 0.7 6.5 2.6 250 12 242 305 9.3 0 9.5 9.2 08/18/2005 17:30:00 4.7 0.7 6.5 3 4.5 0.6 6.1 3 235 8 234 305 9.3 0 9.5 9.2 08/18/2005 17:40:00 4.9 0.6 6.5 3.4 4.6 0.6 6.5 3 249 9 244 305 9.4 0 9.7 9.2 08/18/2005 17:50:00 5.1 0.6 6.8 3.8 4.8 0.6 6.1 3 246 7 252 305 9.2 0 9.5 9.2 08/18/2005 18:00:00 4.8 0.8 7.2 3.4 4.1 0.9 6.8 2.3 261 9 267 305 9.1 0 9.2 8.9 08/18/2005 18:10:00 4.6 0.7 6.1 2.3 4.2 0.7 5.7 2.3 249 11 270 305 8.9 0 9.2 8.9 08/18/2005 18:20:00 4.6 0.7 6.5 2.3 4.3 0.7 5.7 2.3 248 10 268 305 9.1 0 9.2 8.9 08/18/2005 18:30:00 4.8 0.6 6.1 2.6 4.3 0.6 5.7 2.6 253 9 242 305 9.1 0 9.2 8.9 08/18/2005 18:40:00 4.4 0.8 6.1 2.6 4.2 0.8 6.1 2.3 242 7 243 305 9.3 0 9.5 9.2 08/18/2005 18:50:00 4.5 0.6 6.1 3 4.4 0.7 6.1 3 244 9 250 305 9.3 0 9.5 9.2 08/18/2005 19:00:00 4.7 0.5 6.1 3 4.4 0.6 5.7 2.6 249 9 264 305 9.1 0 9.5 8.9 08/18/2005 19:10:00 4.4 0.6 5.7 2.3 4.1 0.6 5.7 1.9 239 9 241 305 8.9 0 9.2 8.9 08/18/2005 19:20:00 5 0.5 6.5 3.8 4.7 0.5 5.7 3.8 238 7 249 305 8.8 0.1 9.2 8.4 08/18/2005 19:30:00 4.8 0.6 6.8 3.4 4.6 0.6 6.5 3 241 9 245 305 8.4 0 8.7 8.2 08/18/2005 19:40:00 4.9 1 6.8 2.6 4.6 0.9 6.5 2.6 243 7 247 305 8.3 0 8.4 8.2 08/18/2005 19:50:00 5.8 0.7 7.2 3.8 5.3 0.8 7.2 3.4 249 8 258 305 8.4 0 8.4 8.2 08/18/2005 20:00:00 4.9 0.8 6.5 3 4.7 0.8 6.5 2.6 244 7 246 305 8.4 0 8.7 8.2 08/18/2005 20:10:00 6.2 0.6 7.2 4.2 5.9 0.6 7.2 3.4 240 6 245 305 8.2 0.1 8.7 7.9 08/18/2005 20:20:00 5.5 0.7 7.2 3.8 5.1 0.8 7.6 3.4 238 7 227 305 8.2 0 8.4 7.9 08/18/2005 20:30:00 6.1 0.7 7.6 4.2 5.7 0.7 6.8 3.8 240 7 248 305 8 0 8.4 7.7 08/18/2005 20:40:00 5.9 0.9 7.6 3.8 5.6 0.8 7.2 3.4 234 7 235 305 7.9 0 7.9 7.7 08/18/2005 20:50:00 5.6 0.9 7.6 3.4 5.1 0.8 7.2 3.4 244 11 258 305 7.9 0 8.2 7.7 08/18/2005 21:00:00 6.2 0.5 7.2 4.6 5.5 0.7 7.2 3.8 243 9 253 305 7.6 0 7.9 7.7 08/18/2005 21:10:00 6.1 0.7 8 4.6 5.5 0.8 7.2 3.4 244 7 242 305 7.5 0 7.7 7.4 08/18/2005 21:20:00 5.6 0.8 8 3 4.9 0.9 7.2 2.6 248 9 253 305 7.7 0.1 7.9 7.7 08/18/2005 21:30:00 5.6 0.6 7.2 3.8 5.2 0.7 7.2 3.4 241 7 239 305 7.8 0 7.9 7.7 08/18/2005 21:40:00 6.2 0.6 7.2 4.2 5.9 0.6 7.2 4.2 235 5 231 305 7.7 0 7.9 7.7 08/18/2005 21:50:00 6 0.6 7.6 4.2 5.6 0.6 7.2 3.4 242 7 248 305 7.4 0 7.7 7.2 08/18/2005 22:00:00 5.7 0.6 7.2 3.8 5.3 0.6 6.8 3.4 231 5 227 305 7.5 0 7.7 7.2 08/18/2005 22:10:00 5.4 0.8 7.6 3.4 4.9 0.8 6.8 3 244 9 251 305 7.5 0 7.7 7.4 08/18/2005 22:20:00 6.3 0.7 8 4.6 5.7 0.8 7.2 3.8 237 7 234 305 7.5 0 7.7 7.4 08/18/2005 22:30:00 5.5 0.7 6.8 3.4 5.2 0.6 6.8 3.4 236 9 234 305 7.6 0 7.7 7.4 08/18/2005 22:40:00 6.5 0.7 8 3.8 6.2 0.7 8 4.2 239 5 242 305 7.6 0 7.9 7.4 08/18/2005 22:50:00 6.3 0.9 8.4 4.2 6 0.9 8.4 3.8 236 7 230 305 7.7 0 7.9 7.7 08/18/2005 23:00:00 5.9 0.8 8 3.8 5.6 0.8 7.6 3.8 240 8 243 305 7.5 0 7.7 7.4 08/18/2005 23:10:00 5.9 0.5 7.2 4.2 5.3 0.6 6.8 4.2 232 7 232 305 7.7 0 7.9 7.7 08/18/2005 23:20:00 6.5 0.7 8.4 4.6 5.9 0.8 8 3.8 235 9 246 305 7.7 0 7.9 7.4 08/18/2005 23:30:00 6.2 0.8 7.6 4.2 5.6 0.9 7.6 3.4 231 7 227 305 7.6 0 7.7 7.4 08/18/2005 23:40:00 6.1 0.7 7.6 3.4 5.7 0.9 7.2 3.4 234 7 234 305 7.7 0 7.9 7.4 08/18/2005 23:50:00 6.8 0.5 8.4 4.9 6.5 0.6 8 4.9 230 6 231 305 7.7 0 7.9 7.7 08/19/2005 00:00:00 6.5 0.6 8 4.9 6.2 0.7 8 4.6 230 5 234 305 7.5 0 8.2 7.4 08/19/2005 00:10:00 6.6 0.6 8.4 4.9 6.2 0.7 7.6 4.2 230 5 221 305 7.4 0 7.7 7.4 08/19/2005 00:20:00 6.2 0.8 8 4.2 5.8 0.8 7.6 3.8 229 6 231 305 7.4 0 7.7 7.2 08/19/2005 00:30:00 6.1 0.7 7.2 4.2 5.8 0.8 7.2 4.2 235 8 234 305 7.6 0 7.9 7.7 08/19/2005 00:40:00 5.8 0.6 7.2 4.2 5.5 0.7 7.2 3.8 232 7 227 305 7.9 0 7.9 7.7 08/19/2005 00:50:00 6.1 0.6 7.6 4.6 5.7 0.6 7.2 4.2 238 6 242 305 7.8 0.1 7.9 7.7 08/19/2005 01:00:00 6.2 0.5 7.2 4.6 5.8 0.6 7.2 4.2 235 7 236 305 7.9 0 8.2 7.7 08/19/2005 01:10:00 6.7 0.9 8.8 4.6 6.1 1 8.4 3.8 238 9 231 305 7.8 0.1 8.2 7.4 08/19/2005 01:20:00 6.8 0.6 8.4 4.9 6.2 0.7 7.6 4.2 235 6 244 305 7.3 0 7.7 7.2 08/19/2005 01:30:00 6.5 0.7 8.4 4.6 5.8 0.8 7.6 4.2 229 6 234 305 7.4 0 7.7 7.2 08/19/2005 01:40:00 5.9 0.8 7.6 4.2 5.3 0.9 7.2 3.4 243 9 245 305 7.7 0 7.9 7.7 08/19/2005 01:50:00 6 0.6 7.6 4.2 5.3 0.8 7.2 3 244 13 232 305 7.8 0 7.9 7.7 08/19/2005 02:00:00 5.9 0.6 7.2 4.2 5.3 0.7 7.2 3.8 241 8 244 305 7.8 0 7.9 7.7 08/19/2005 02:10:00 6.5 1 8.8 3.8 6 0.9 8.4 3.4 237 10 252 305 7.8 0 7.9 7.7 08/19/2005 02:20:00 6.3 0.7 8.4 4.2 5.6 0.7 7.6 4.2 238 8 236 305 8 0 8.2 7.9 08/19/2005 02:30:00 6.6 1 8.8 4.2 6 1 8 3.8 234 6 226 305 7.8 0 7.9 7.7 08/19/2005 02:40:00 6.5 0.7 8 4.6 6 0.8 7.6 3.8 234 7 238 305 7.7 0 8.2 7.7 08/19/2005 02:50:00 6.9 0.7 8.4 4.6 6.3 0.8 8 3.8 227 7 233 305 8 0 8.2 7.9 08/19/2005 03:00:00 6.5 0.7 8.4 4.9 6 0.8 8.4 3.8 225 7 237 305 7.7 0 8.2 7.7 08/19/2005 03:10:00 6.6 0.7 8.8 5.3 6.4 0.8 8.4 4.6 225 6 221 305 7.7 0 7.9 7.4 08/19/2005 03:20:00 7 0.6 8.4 4.9 6.6 0.7 8 4.9 227 7 235 305 7.8 0 7.9 7.7 08/19/2005 03:30:00 7 0.6 8.4 5.3 6.7 0.6 8.4 4.9 221 5 218 305 7.9 0 7.9 7.7 08/19/2005 03:40:00 6.6 0.7 8.4 4.9 6.3 0.8 8.8 4.6 229 7 219 305 7.8 0 8.2 7.7 08/19/2005 03:50:00 7 0.7 8.8 5.3 6.7 0.7 8.8 4.9 225 6 234 305 7.9 0 7.9 7.7 08/19/2005 04:00:00 7.1 0.5 8.4 5.7 6.8 0.6 8.4 4.9 227 4 230 305 7.9 0 8.2 7.7 08/19/2005 04:10:00 7 0.6 8.4 5.3 6.6 0.7 8.4 4.2 224 6 233 305 8.1 0 8.4 7.9 08/19/2005 04:20:00 6.5 0.8 8.4 4.6 6.1 0.8 8 4.2 227 5 221 305 8 0 8.2 7.9 08/19/2005 04:30:00 6.6 0.7 8.4 4.2 6.2 0.7 7.6 4.2 225 6 217 305 8.1 0 8.2 7.9 08/19/2005 04:40:00 7.7 0.6 9.5 5.7 7.2 0.7 8.8 4.9 232 6 231 305 8 0 8.2 7.9 08/19/2005 04:50:00 7.1 0.6 8.4 5.3 6.7 0.7 8.4 4.9 223 5 221 305 8.1 0 8.2 7.9 08/19/2005 05:00:00 7.7 0.7 9.1 5.7 7.2 0.8 9.1 5.3 226 5 234 305 8.2 0 8.4 8.2 08/19/2005 05:10:00 8.2 0.8 9.9 5.7 7.5 0.8 9.5 5.3 234 6 235 305 8.3 0 8.4 8.2 08/19/2005 05:20:00 8.9 0.9 11.1 6.5 8.2 1 10.7 5.7 234 6 239 305 8.4 0 8.4 8.2 08/19/2005 05:30:00 8.9 0.6 11.1 7.2 8.3 0.8 10.3 6.1 233 5 238 305 8.5 0 8.7 8.4 08/19/2005 05:40:00 8.5 0.7 10.7 6.5 8 0.7 10.3 5.3 231 5 226 305 8.6 0.1 8.9 8.4 08/19/2005 05:50:00 8.7 1.1 11.1 5.7 8.2 1.1 9.9 4.9 237 7 238 305 8.8 0 8.9 8.7 08/19/2005 06:00:00 7.7 0.7 10.3 5.7 7.2 0.8 9.9 4.9 232 5 236 305 8.9 0 9.2 8.9 08/19/2005 06:10:00 8.9 0.9 11.1 6.5 8.2 1 10.3 5.7 242 7 247 305 8.9 0 9.2 8.9 08/19/2005 06:20:00 8.1 0.7 10.7 6.1 7.4 0.8 10.7 5.3 238 6 234 305 9 0 9.2 8.9 08/19/2005 06:30:00 7.8 1.2 10.3 5.3 7.2 1 10.3 4.9 241 7 246 305 9.2 0 9.2 8.9 08/19/2005 06:40:00 9.2 0.8 10.7 6.5 8.5 0.9 10.3 6.1 242 6 239 305 9.1 0 9.2 9.2 08/19/2005 06:50:00 9.5 0.8 11.1 6.5 8.9 0.9 10.7 5.7 240 4 237 305 9.1 0 9.2 9.2 08/19/2005 07:00:00 9.3 0.9 11.1 6.8 8.6 0.9 10.7 6.1 237 5 247 305 9.1 0 9.2 9.2 08/19/2005 07:10:00 8.6 1 10.7 5.3 7.9 1.1 9.9 4.9 240 9 233 305 9.1 0 9.2 8.9 08/19/2005 07:20:00 8.9 0.8 11.1 6.8 8.1 0.8 10.3 5.7 242 8 250 305 9.1 0 9.2 8.9 08/19/2005 07:30:00 8.9 0.8 10.7 6.8 8 1 10.7 4.9 251 6 245 305 8.9 0 9.2 8.9 08/19/2005 07:40:00 7.8 0.9 9.5 5.7 6.9 0.9 9.1 4.2 248 7 252 305 9 0 9.2 8.9 08/19/2005 07:50:00 7.7 0.9 9.9 5.3 6.9 0.9 9.1 4.6 239 7 242 305 9.1 0 9.2 8.9 08/19/2005 08:00:00 8.4 1 10.7 5.7 7.8 1.1 10.3 4.6 240 6 241 305 9.1 0 9.2 8.9 08/19/2005 08:10:00 8.6 1.3 10.7 4.6 7.8 1.5 10.7 3.8 239 7 237 305 9.1 0 9.2 8.9 08/19/2005 08:20:00 8.5 0.9 10.7 6.1 7.8 1 10.3 5.3 237 5 238 305 9 0 9.2 8.9 08/19/2005 08:30:00 9 0.8 11.1 6.5 8.2 0.9 10.7 6.1 233 5 241 305 9.1 0 9.2 8.9 08/19/2005 08:40:00 9 1 11.1 6.1 8.3 1 11.1 5.3 237 8 232 305 9.1 0 9.2 8.9 08/19/2005 08:50:00 8.7 1 11.1 6.1 8 1.1 11.1 4.9 242 6 244 305 9.1 0 9.2 8.9 08/19/2005 09:00:00 9.4 1 11.5 6.8 8.6 1.2 11.1 5.7 245 6 246 305 9 0 9.2 8.9 08/19/2005 09:10:00 9.4 1.1 11.8 5.7 8.5 1.3 11.5 4.9 242 6 245 305 9.1 0 9.2 8.9 08/19/2005 09:20:00 9.9 1 12.2 7.2 9.2 1.2 11.8 5.7 246 5 247 305 9.1 0 9.2 8.9 08/19/2005 09:30:00 9.6 0.9 11.5 6.5 8.8 1 11.1 6.5 239 6 238 305 9.2 0 9.2 9.2 08/19/2005 09:40:00 9.9 0.8 11.8 7.6 9.1 1 11.5 5.7 241 5 241 305 9.2 0 9.5 9.2 08/19/2005 09:50:00 9.1 0.9 11.1 6.1 8.4 1 10.3 5.3 242 5 240 305 9.3 0 9.5 9.2 08/19/2005 10:00:00 9.8 0.8 11.8 5.7 9.1 0.9 10.7 6.1 247 5 252 305 9.4 0 9.5 9.2 08/19/2005 10:10:00 8.9 1 11.1 6.5 8.3 1 11.1 5.7 242 6 250 305 9.5 0 9.7 9.2 08/19/2005 10:20:00 8.7 0.7 10.7 6.8 8 0.8 9.9 6.1 239 6 225 305 9.6 0 9.7 9.5 08/19/2005 10:30:00 8.3 0.8 10.3 5.7 7.6 1 9.9 5.3 237 6 239 305 9.8 0 10 9.7 08/19/2005 10:40:00 7.6 0.6 8.8 5.3 7 0.7 8.8 4.9 233 5 238 305 10 0 10.2 10 08/19/2005 10:50:00 7.6 0.7 9.5 5.3 7.1 0.7 8.8 5.3 232 5 238 305 10 0 10.2 10 08/19/2005 11:00:00 7.6 0.7 9.5 6.1 7.1 0.8 8.8 4.9 232 5 239 305 10 0 10.2 10 08/19/2005 11:10:00 8.1 0.8 9.9 5.7 7.7 0.8 9.1 5.3 233 5 234 305 10.1 0 10.2 10 08/19/2005 11:20:00 8.2 0.8 10.3 6.1 7.4 0.8 9.1 5.3 236 5 239 305 10.2 0 10.2 10 08/19/2005 11:30:00 7.3 0.6 9.1 5.7 6.8 0.7 8.8 4.9 235 5 237 305 10.2 0 10.2 10.2 08/19/2005 11:40:00 7.1 0.6 8.8 4.9 6.6 0.7 8 4.6 229 6 215 305 10.3 0 10.5 10.2 08/19/2005 11:50:00 7.1 0.7 8.4 4.9 6.5 0.7 8.4 4.9 231 5 235 305 10.3 0 10.5 10.2 08/19/2005 12:00:00 7.4 0.7 9.1 5.7 6.8 0.7 8.4 4.9 228 5 230 305 10.4 0 10.5 10.2 08/19/2005 12:10:00 7.6 0.7 9.1 5.7 7 0.7 8.8 4.9 232 6 231 305 10.3 0 10.5 10.2 08/19/2005 12:20:00 7.9 0.9 9.9 5.7 7.3 0.9 9.5 4.9 235 6 234 305 10.3 0 10.5 10.2 08/19/2005 12:30:00 8.7 0.8 10.7 6.1 7.9 0.9 10.3 5.3 237 5 242 305 10.4 0 10.5 10.2 08/19/2005 12:40:00 9 0.9 11.1 6.8 8.2 0.9 10.3 5.7 237 6 236 305 10.4 0 10.5 10.2 08/19/2005 12:50:00 9.9 1 13 7.6 9.2 1 11.8 6.5 237 6 244 305 10.3 0 10.5 10.2 08/19/2005 13:00:00 9.5 1 11.8 6.8 8.7 1 11.5 5.7 239 5 247 305 10.3 0 10.5 10.2 08/19/2005 13:10:00 9.2 0.9 11.1 6.1 8.3 1 11.1 6.1 237 6 238 305 10.3 0 10.2 10.2 08/19/2005 13:20:00 9.7 1 12.2 6.8 8.8 1.1 11.5 6.8 236 5 236 305 10.3 0 10.5 10.2 08/19/2005 13:30:00 9 0.8 11.1 6.5 8.2 0.9 10.3 6.1 233 5 237 305 10.4 0 10.5 10.2 08/19/2005 13:40:00 9.5 0.8 11.1 7.2 8.8 0.8 11.1 6.5 234 5 228 305 10.3 0 10.5 10.2 08/19/2005 13:50:00 9.8 1 12.2 7.2 8.8 1.2 11.8 6.5 238 6 244 305 10.3 0 10.5 10.2 08/19/2005 14:00:00 9 0.9 11.1 6.1 8.2 0.9 10.7 6.1 239 6 239 305 10.2 0 10.2 10.2 08/19/2005 14:10:00 8.5 0.9 10.7 5.7 7.7 0.8 9.9 5.7 238 6 238 305 10.2 0 10.2 10.2 08/19/2005 14:20:00 8.9 0.8 10.7 6.8 8 0.9 9.9 5.7 236 6 235 305 10.2 0 10.2 10.2 08/19/2005 14:30:00 8.6 0.7 10.7 6.8 7.9 0.8 9.9 5.7 234 6 234 305 10.2 0 10.2 10 08/19/2005 14:40:00 8.7 0.7 10.7 6.8 8 0.8 9.9 6.1 230 5 228 305 10 0 10.2 10 08/19/2005 14:50:00 8.5 0.7 9.9 6.1 7.6 0.8 9.5 5.7 228 5 233 305 9.9 0 10 9.7 08/19/2005 15:00:00 7.8 0.7 9.5 5.7 7.2 0.8 9.1 5.3 233 5 235 305 9.9 0 10 9.7 08/19/2005 15:10:00 8.1 0.6 9.5 6.5 7.5 0.6 9.1 6.1 232 5 234 305 9.9 0 10 9.7 08/19/2005 15:20:00 8.2 0.6 10.3 6.1 7.6 0.7 9.1 5.7 233 5 231 305 9.9 0 10 9.7 08/19/2005 15:30:00 9.2 0.7 11.1 7.2 8.5 0.7 10.7 6.1 233 5 236 305 9.9 0 10 9.7 08/19/2005 15:40:00 9.5 0.8 12.2 7.2 8.7 0.9 11.1 6.5 233 6 237 305 9.9 0 10 9.7 08/19/2005 15:50:00 9.4 0.8 11.5 6.8 8.5 0.8 10.3 6.5 235 6 237 305 10 0 10.2 9.7 08/19/2005 16:00:00 10 0.8 11.8 7.6 9.1 0.9 11.5 6.5 238 6 245 305 10 0 10.2 10 08/19/2005 16:10:00 9.2 0.8 11.1 6.8 8.3 0.8 9.9 6.5 235 6 256 305 10 0 10.2 10 08/19/2005 16:20:00 9.4 1.2 11.8 6.1 8.5 1.3 11.5 5.3 236 6 242 305 10 0 10.2 9.7 08/19/2005 16:30:00 9.3 1.2 11.5 6.5 8.4 1.1 11.5 6.1 235 6 234 305 9.9 0 10.2 9.7 08/19/2005 16:40:00 9.9 0.9 12.2 7.2 9 1 11.8 6.5 237 6 236 305 10 0 10.2 10 08/19/2005 16:50:00 9.6 1 11.8 6.8 8.6 1 11.1 6.1 237 6 234 305 9.9 0 10 10 08/19/2005 17:00:00 9.4 0.8 11.1 6.5 8.4 0.9 10.7 6.1 237 6 241 305 9.9 0 10 9.7 08/19/2005 17:10:00 8.5 0.8 10.7 6.5 7.6 0.8 9.5 5.7 235 6 240 305 9.9 0 10 9.7 08/19/2005 17:20:00 8.7 0.9 10.7 6.5 7.8 0.9 9.9 5.7 236 5 236 305 9.9 0 10 9.7 08/19/2005 17:30:00 9.2 1 12.2 6.5 8.2 1 11.1 5.7 236 5 241 305 9.9 0 10.2 9.7 08/19/2005 17:40:00 9 1 11.1 6.5 8.1 1 10.3 6.1 234 6 238 305 10 0 10.2 10 08/19/2005 17:50:00 8.8 0.8 10.7 6.5 8.2 0.8 10.7 5.7 232 5 234 305 10 0 10.2 9.7 08/19/2005 18:00:00 8.7 0.7 11.1 6.8 8 0.8 9.9 6.1 233 6 241 305 10.1 0 10.2 10 08/19/2005 18:10:00 8.8 0.7 11.1 6.8 8 0.8 10.3 6.1 234 6 245 305 10.2 0 10.2 10.2 08/19/2005 18:20:00 9.1 0.7 10.7 6.8 8.1 0.9 9.9 5.7 237 6 235 305 10.2 0 10.2 10.2 08/19/2005 18:30:00 9.4 0.8 11.5 6.8 8.3 0.8 10.3 6.1 238 6 242 305 10.2 0 10.2 10.2 08/19/2005 18:40:00 9.6 0.8 11.5 6.8 8.6 0.9 10.7 6.1 236 6 238 305 10.3 0 10.2 10.2 08/19/2005 18:50:00 10 0.8 11.8 8 9.1 0.8 11.1 7.2 238 5 241 305 10.2 0 10.2 10.2 08/19/2005 19:00:00 10 0.8 12.6 8.4 9.1 0.8 11.8 6.1 239 6 240 305 10.2 0 10.2 10 08/19/2005 19:10:00 9.5 0.8 11.1 7.2 8.5 0.8 10.7 6.5 237 6 239 305 10.2 0 10.2 10 08/19/2005 19:20:00 9.2 0.8 11.1 6.8 8 0.8 10.3 5.7 236 6 238 305 10.2 0 10.2 10 08/19/2005 19:30:00 9.5 0.7 11.1 7.2 8.7 0.7 10.3 6.5 234 6 231 305 10.2 0 10.2 10.2 08/19/2005 19:40:00 9.2 0.8 11.1 6.5 8.3 0.9 10.3 6.1 235 6 239 305 10.2 0 10.2 10.2 08/19/2005 19:50:00 9.6 0.7 11.5 7.2 8.4 0.8 10.7 6.5 236 5 233 305 10.2 0 10.2 10 08/19/2005 20:00:00 9.2 0.9 11.1 6.5 8.2 1 11.1 6.1 236 6 237 305 10.2 0 10.2 10 08/19/2005 20:10:00 9.5 0.8 11.5 6.8 8.6 0.9 10.7 6.1 237 6 231 305 10.2 0 10.2 10.2 08/19/2005 20:20:00 10.3 0.8 12.2 8 9.6 0.8 11.5 6.8 241 5 245 305 10.2 0 10.2 10.2 08/19/2005 20:30:00 9.5 1 12.2 6.8 8.7 0.9 11.1 6.1 241 5 248 305 10.3 0 10.2 10.2 08/19/2005 20:40:00 9 0.8 11.1 6.5 8.3 0.9 10.3 4.9 243 6 250 305 10.2 0 10.2 10.2 08/19/2005 20:50:00 9.3 1.3 12.2 5.7 8.4 1.3 11.8 4.9 248 7 250 305 10.2 0 10.2 10 08/19/2005 21:00:00 9.5 0.9 11.1 6.5 8.8 1 11.1 6.1 248 5 243 305 10.1 0 10.2 10 08/19/2005 21:10:00 8.8 0.9 11.1 6.5 8 1.1 10.3 4.9 253 6 257 305 10 0 10.2 9.7 08/19/2005 21:20:00 9.4 1.1 12.2 6.5 8.6 1.2 11.8 5.3 247 6 243 305 9.9 0 10 9.7 08/19/2005 21:30:00 9 1 11.1 6.1 8.3 1 10.7 4.9 246 6 251 305 9.7 0 10 9.7 08/19/2005 21:40:00 9.2 1.2 11.8 5.3 8.6 1.3 11.5 4.9 247 6 253 305 9.7 0 9.7 9.7 08/19/2005 21:50:00 8.9 1 11.1 5.7 8.1 1.1 11.1 5.7 244 7 238 305 9.7 0 9.7 9.7 08/19/2005 22:00:00 9.2 0.9 11.8 6.8 8.6 1 11.5 5.7 244 5 247 305 9.7 0 9.7 9.5 08/19/2005 22:10:00 8.2 1 9.9 5.3 7.5 1 9.5 4.9 244 6 250 305 9.7 0 9.7 9.5 08/19/2005 22:20:00 8.2 1 10.7 5.3 7.3 1 9.9 4.9 245 6 251 305 9.7 0 10 9.7 08/19/2005 22:30:00 8.3 1 10.3 5.7 7.4 1.1 9.9 4.6 245 6 250 305 9.9 0 10 9.7 08/19/2005 22:40:00 7.7 0.8 9.5 5.7 6.9 0.9 9.1 4.9 246 6 246 305 10 0 10 10 08/19/2005 22:50:00 7.9 0.8 9.9 5.7 6.9 1 9.5 4.6 245 6 251 305 10 0 10.2 10 08/19/2005 23:00:00 8 0.8 9.9 5.7 7.1 0.9 9.5 4.6 244 6 250 305 10.1 0 10.2 10 08/19/2005 23:10:00 8 0.8 9.9 6.1 7.1 0.9 9.5 4.9 243 6 259 305 10.2 0 10.2 10 08/19/2005 23:20:00 7.9 0.8 9.9 4.9 6.9 1 9.1 3.8 245 6 247 305 10.1 0 10.2 10 08/19/2005 23:30:00 7.6 0.8 9.1 4.6 6.6 0.9 8.8 4.2 244 6 236 305 10.1 0 10.2 10 08/19/2005 23:40:00 7.4 0.7 9.1 5.7 6.6 0.8 8.8 3.8 243 6 248 305 10.1 0 10.2 10 08/19/2005 23:50:00 8 0.9 10.3 5.3 7.1 1 9.5 4.2 243 6 244 305 10.1 0 10.2 10 08/20/2005 00:00:00 7.7 0.7 9.1 5.3 7 0.7 8.4 4.9 240 6 249 305 10.1 0 10.5 10 08/20/2005 00:10:00 8 0.7 9.5 6.1 7.2 0.7 9.1 5.3 239 6 238 305 10.2 0 10.2 10 08/20/2005 00:20:00 7.8 0.7 9.5 5.3 7.1 0.8 9.1 4.9 241 6 250 305 10.1 0 10.2 10 08/20/2005 00:30:00 8.1 0.8 9.9 5.7 7.3 0.8 9.1 5.3 241 6 238 305 10.2 0 10.2 10 08/20/2005 00:40:00 8.4 0.8 9.9 6.1 7.7 0.8 9.5 5.3 241 6 242 305 10.2 0 10.2 10 08/20/2005 00:50:00 8.8 0.8 10.7 6.5 8 1 10.3 5.7 240 5 239 305 10.1 0 10.2 10 08/20/2005 01:00:00 8.8 0.7 11.1 6.8 8.1 0.9 11.1 5.7 242 5 241 305 10.1 0 10.2 10 08/20/2005 01:10:00 8.9 0.7 10.7 6.8 8.2 0.7 9.5 6.5 243 5 252 305 10 0 10.2 10 08/20/2005 01:20:00 8.9 0.9 11.5 6.5 8 1 10.3 5.3 245 6 248 305 10 0 10.2 10 08/20/2005 01:30:00 9.2 0.8 11.1 6.5 8.3 1.1 11.1 4.9 247 6 256 305 10 0 10.2 10 08/20/2005 01:40:00 8.8 0.9 11.1 6.1 7.9 1.1 10.3 5.3 246 6 242 305 9.9 0 10 9.7 08/20/2005 01:50:00 9.1 0.8 10.7 6.5 8.3 1 10.7 5.3 247 6 246 305 9.9 0 10 9.7 08/20/2005 02:00:00 8.9 0.8 11.1 6.5 8.2 1 10.7 5.3 247 6 247 305 9.9 0 10 9.7 08/20/2005 02:10:00 8.4 0.9 10.3 5.7 7.5 1.1 10.7 4.2 246 6 247 305 9.9 0 10 9.7 08/20/2005 02:20:00 7.7 0.8 9.1 5.3 6.8 1 9.1 4.6 249 7 248 305 9.9 0 10 9.7 08/20/2005 02:30:00 7 0.9 8.8 3.8 5.9 1 8.4 3.4 253 8 259 305 9.9 0 10 9.7 08/20/2005 02:40:00 6.8 0.8 8.4 3.8 5.2 1 7.2 2.6 259 7 262 305 9.9 0 10 9.7 08/20/2005 02:50:00 5.9 0.8 7.6 3.8 4.5 0.7 6.8 3 268 8 275 305 9.9 0 10 9.7 08/20/2005 03:00:00 6.4 1 8.8 4.2 4.9 0.8 7.2 2.6 266 8 266 305 9.9 0 10 9.7 08/20/2005 03:10:00 6.8 0.9 9.1 4.2 5.1 0.9 7.2 2.6 269 7 277 305 9.9 0 10 9.7 08/20/2005 03:20:00 5.7 0.8 8 3.4 4.2 0.7 6.5 2.6 270 7 277 305 9.9 0 10 9.7 08/20/2005 03:30:00 5.5 0.9 7.6 3 4.3 0.8 6.5 2.3 263 9 268 305 9.9 0 10 10 08/20/2005 03:40:00 5.3 0.6 7.2 3.8 4.6 0.7 6.1 3 248 8 248 305 9.9 0 10 9.7 08/20/2005 03:50:00 6.2 0.9 7.6 3.4 5.4 0.9 7.2 3 238 6 238 305 9.9 0 10 9.7 08/20/2005 04:00:00 6.5 0.6 7.6 4.6 5.5 0.6 7.2 3.8 240 5 252 305 9.9 0 10 10 08/20/2005 04:10:00 6 0.5 6.8 4.6 5.1 0.5 6.5 3.8 241 5 238 305 9.9 0 10 9.7 08/20/2005 04:20:00 6.5 0.5 7.6 4.6 5.6 0.6 7.2 3.8 241 5 238 305 9.9 0 10 10 08/20/2005 04:30:00 5.9 0.6 7.2 4.2 4.9 0.6 6.8 3.4 240 6 239 305 9.9 0 10 10 08/20/2005 04:40:00 5.8 0.6 7.2 3.8 4.9 0.7 6.5 3.4 242 5 245 305 9.9 0 10 10 08/20/2005 04:50:00 5.2 0.5 6.5 3.8 4.7 0.6 6.1 3 242 7 244 305 9.9 0 10 10 08/20/2005 05:00:00 5.2 0.5 6.5 3.8 4.5 0.5 5.7 3 238 5 244 305 9.9 0 10 9.7 08/20/2005 05:10:00 4.8 0.5 6.1 3.4 4.2 0.4 5.7 3 236 5 239 305 9.9 0 10 9.7 08/20/2005 05:20:00 4.8 0.5 5.7 3.4 4.4 0.4 5.3 3 234 5 236 305 9.9 0 10 9.7 08/20/2005 05:30:00 5.3 0.5 6.1 3.8 4.6 0.5 5.7 3 236 4 236 305 9.9 0 10 9.7 08/20/2005 05:40:00 6 0.6 8 4.6 5.2 0.6 7.2 3.4 241 6 251 305 9.9 0 10 9.7 08/20/2005 05:50:00 6.3 0.7 7.6 3.8 5.3 0.9 7.2 3 251 6 259 305 9.7 0 10 9.7 08/20/2005 06:00:00 6.2 0.5 7.6 4.2 5.1 0.6 6.8 3 248 6 249 305 9.7 0 9.7 9.7 08/20/2005 06:10:00 6.6 0.7 8 4.6 5.5 0.8 7.2 3 246 6 242 305 9.7 0 9.7 9.7 08/20/2005 06:20:00 6.5 0.6 7.6 4.9 5.6 0.7 7.2 3.4 244 6 251 305 9.7 0 10 9.7 08/20/2005 06:30:00 6.7 0.8 8.8 4.2 5.5 1 8 3 246 6 246 305 9.7 0 9.7 9.7 08/20/2005 06:40:00 6.4 0.6 8 4.2 5.4 0.7 7.6 3.8 244 5 245 305 9.7 0 9.7 9.7 08/20/2005 06:50:00 6.4 0.6 8 4.9 5.4 0.7 6.8 3.8 243 5 245 305 9.7 0 10 9.7 08/20/2005 07:00:00 6.4 0.5 8 4.9 5.5 0.7 7.2 4.2 242 6 245 305 9.7 0 10 9.7 08/20/2005 07:10:00 6.9 0.4 8 5.7 5.9 0.6 6.8 3.8 243 4 250 305 9.7 0 10 9.7 08/20/2005 07:20:00 5.9 0.5 7.2 4.2 5 0.6 6.5 3.8 237 5 239 305 9.8 0 10 9.7 08/20/2005 07:30:00 5.4 0.8 6.8 3 4.7 0.8 6.5 3 230 6 237 305 9.9 0 10 9.7 08/20/2005 07:40:00 5.5 0.6 6.5 3.8 4.9 0.6 6.1 3 224 5 223 305 9.9 0 10 9.7 08/20/2005 07:50:00 5.7 0.5 6.5 3.8 5.2 0.5 6.5 3.8 223 4 223 305 9.9 0 10 9.7 08/20/2005 08:00:00 5.2 0.4 6.1 4.2 4.8 0.5 6.1 3 219 5 221 305 9.9 0 10 9.7 08/20/2005 08:10:00 5.3 0.5 6.8 4.2 4.9 0.5 6.1 3.4 216 5 220 305 9.8 0 10 9.7 08/20/2005 08:20:00 6.3 0.5 7.6 4.6 5.8 0.6 7.2 4.2 216 5 214 305 9.9 0 10 9.7 08/20/2005 08:30:00 6.8 0.7 8.4 4.9 6.3 0.7 7.6 4.2 216 6 221 305 9.9 0 10 9.7 08/20/2005 08:40:00 8.2 0.6 9.5 6.5 7.6 0.6 9.1 5.7 216 5 225 305 9.9 0 10 9.7 08/20/2005 08:50:00 8.6 0.5 9.5 6.8 7.8 0.7 9.1 5.7 221 5 218 305 9.8 0 10 9.7 08/20/2005 09:00:00 8.1 0.6 9.5 5.7 7.5 0.6 9.1 5.7 221 4 221 305 9.7 0 10 9.7 08/20/2005 09:10:00 6.7 0.8 8.4 4.6 5.9 0.9 8 3.8 226 5 215 305 9.9 0 10 9.7 08/20/2005 09:20:00 7.2 0.9 8.8 4.9 6.5 1 8.4 4.2 223 6 222 305 10 0 10 9.7 08/20/2005 09:30:00 6.8 0.5 8 4.9 6.2 0.6 7.6 4.6 229 5 225 305 9.9 0 10 9.7 08/20/2005 09:40:00 5.9 0.5 6.8 4.6 5.5 0.6 6.5 4.2 216 5 221 305 9.8 0 10 9.7 08/20/2005 09:50:00 5.6 0.6 6.8 4.2 5.2 0.6 6.8 3.4 217 5 221 305 9.9 0 10 9.7 08/20/2005 10:00:00 5.3 0.5 6.5 3.8 4.9 0.5 6.5 3.4 215 6 223 305 10 0 10.2 10 08/20/2005 10:10:00 5.2 0.4 6.5 3.8 5 0.5 6.1 3.4 214 5 218 305 10 0 10.2 10 08/20/2005 10:20:00 5.3 0.4 6.1 4.2 5.1 0.5 6.1 3.4 212 5 214 305 10 0 10.2 10 08/20/2005 10:30:00 5.1 0.6 6.5 3 4.7 0.6 6.5 3 213 6 208 305 10 0 10.2 10 08/20/2005 10:40:00 5.5 0.5 6.8 4.2 5.1 0.6 6.8 3.4 213 5 218 305 9.9 0 10 9.7 08/20/2005 10:50:00 5.5 0.4 6.5 3.8 5.1 0.5 6.5 3.8 215 6 211 305 9.7 0 9.7 9.7 08/20/2005 11:00:00 5.1 0.5 6.1 3.8 4.8 0.5 6.1 3.4 225 6 223 305 9.6 0 9.7 9.5 08/20/2005 11:10:00 5.1 0.5 6.1 3.8 4.6 0.5 5.7 3.4 229 5 221 305 9.5 0 9.7 9.5 08/20/2005 11:20:00 4.9 0.5 6.1 3.4 4.5 0.5 5.7 3.4 232 5 231 305 9.5 0 9.7 9.2 08/20/2005 11:30:00 4.3 0.5 6.1 2.6 3.9 0.5 5.3 2.6 231 6 234 305 9.6 0 9.7 9.5 08/20/2005 11:40:00 4.5 0.5 5.3 3.4 4.1 0.5 5.3 2.6 228 6 228 305 9.8 0 10 9.7 08/20/2005 11:50:00 4.6 0.6 6.5 3.4 4.3 0.5 5.7 3 230 6 232 305 10.1 0 10.2 10 08/20/2005 12:00:00 5.5 0.6 6.5 3.4 5.2 0.6 6.5 3.4 230 5 231 305 10.2 0 10.2 10 08/20/2005 12:10:00 5.7 0.8 7.6 3.8 5.2 0.8 7.2 3.4 236 6 246 305 10.2 0 10.2 10 08/20/2005 12:20:00 5.9 0.7 7.6 4.6 5.5 0.8 7.2 3 247 7 238 305 9.9 0 10.2 9.7 08/20/2005 12:30:00 4.7 0.5 6.5 3.4 4.4 0.5 6.1 3 238 6 246 305 9.7 0 10 9.7 08/20/2005 12:40:00 4.5 0.6 5.7 3 4.3 0.5 5.7 3 233 6 236 305 9.8 0 10 9.7 08/20/2005 12:50:00 4.4 0.5 5.3 3 4.2 0.6 5.7 3 237 7 246 305 10 0 10.2 9.7 08/20/2005 13:00:00 4.3 0.5 5.3 3 4 0.6 5.3 2.6 245 7 252 305 10.3 0 10.5 10.2 08/20/2005 13:10:00 4.2 0.5 4.9 3 4.1 0.4 4.9 3 236 7 244 305 10.4 0 10.8 10.2 08/20/2005 13:20:00 5 0.5 6.1 3.4 4.8 0.5 5.7 3.4 228 5 228 305 10.3 0 10.5 10.2 08/20/2005 13:30:00 5.3 0.5 6.1 3.8 5.1 0.5 6.1 3.8 236 6 234 305 10.3 0 10.5 10.2 08/20/2005 13:40:00 5.7 0.6 7.2 3.8 5.3 0.8 7.2 3 250 7 247 305 10.2 0 10.5 10 08/20/2005 13:50:00 5.1 0.7 6.5 3 4.7 0.9 6.5 2.3 250 8 250 305 9.9 0 10.2 9.7 08/20/2005 14:00:00 4.4 0.6 5.7 3 4.2 0.6 5.3 2.6 248 7 253 305 9.7 0 9.7 9.5 08/20/2005 14:10:00 4.3 0.5 5.3 2.6 4.1 0.5 5.3 3 241 6 248 305 9.8 0 10 9.7 08/20/2005 14:20:00 4.6 0.5 5.7 3 4.3 0.6 5.7 3 244 6 246 305 9.8 0 10 9.7 08/20/2005 14:30:00 5.8 0.8 7.6 3.4 5.3 0.9 7.2 3.4 245 10 249 305 9.8 0 10 9.7 08/20/2005 14:40:00 4.9 0.7 6.5 2.6 4.5 0.6 6.1 2.6 251 9 256 305 9.8 0 10 9.7 08/20/2005 14:50:00 5 0.7 6.5 3.4 4.7 0.6 6.5 3 241 7 243 305 10.2 0.2 10.5 9.7 08/20/2005 15:00:00 5.3 0.7 7.6 3.4 5 0.6 7.2 3.4 238 7 231 305 10.3 0 10.5 10 08/20/2005 15:10:00 5.4 0.6 7.2 4.2 5 0.6 6.8 3.8 235 6 227 305 10.4 0.1 10.8 10.2 08/20/2005 15:20:00 6.4 0.9 8 4.6 5.9 0.8 8 3.8 236 6 237 305 10.6 0.1 11 10.2 08/20/2005 15:30:00 6.7 0.6 8 4.9 6.3 0.7 8 4.6 240 5 233 305 10 0.1 10.5 9.7 08/20/2005 15:40:00 6.3 0.6 7.6 4.6 5.8 0.7 8 4.2 247 8 247 305 9.7 0 10 9.7 08/20/2005 15:50:00 6 0.7 7.6 4.2 5.5 0.6 6.8 3.4 241 6 240 305 9.7 0 10 9.5 08/20/2005 16:00:00 6.7 0.6 8 4.9 6.1 0.6 7.6 4.6 242 5 238 305 9.8 0 10 9.7 08/20/2005 16:10:00 6.6 0.8 8 4.6 6.2 0.8 7.6 4.2 245 6 246 305 10.2 0 10.5 10 08/20/2005 16:20:00 6 0.8 7.2 3.8 5.6 0.8 7.2 3.8 242 8 244 305 10 0 10.2 9.7 08/20/2005 16:30:00 5.8 0.7 7.2 3.8 5.4 0.7 7.2 3.8 244 6 239 305 9.7 0 10 9.7 08/20/2005 16:40:00 5.9 0.6 7.2 4.2 5.3 0.6 6.8 3.8 243 6 256 305 9.7 0 10 9.7 08/20/2005 16:50:00 6.4 0.7 8 3.8 5.6 0.8 7.2 3.4 247 9 253 305 9.8 0 10 9.7 08/20/2005 17:00:00 6.5 0.9 8.4 3.4 5.8 1 7.6 3 248 7 256 305 10.2 0 10.2 10 08/20/2005 17:10:00 6.6 1.1 8.4 3.8 6.1 1.1 8.4 3.8 244 8 246 305 10.2 0 10.5 10.2 08/20/2005 17:20:00 6.4 0.8 8 4.6 5.8 0.7 7.6 3.8 236 6 241 305 10.2 0 10.2 10 08/20/2005 17:30:00 6.8 0.6 8 4.9 6.2 0.7 7.6 4.6 235 5 230 305 10 0 10.2 10 08/20/2005 17:40:00 7.1 0.6 8.4 5.3 6.4 0.6 8 4.9 232 5 234 305 10 0 10.2 10 08/20/2005 17:50:00 6.6 0.6 8 5.3 5.8 0.6 7.6 3.8 234 6 232 305 10.1 0 10.2 10 08/20/2005 18:00:00 7 0.6 8.4 4.9 6.2 0.6 7.6 4.6 233 6 229 305 10 0 10.2 10 08/20/2005 18:10:00 6.7 0.9 8.4 4.2 6 0.8 8 3.8 235 6 239 305 9.9 0 10.2 9.7 08/20/2005 18:20:00 6.7 0.5 8 5.7 6.1 0.6 7.6 4.6 232 5 237 305 10 0 10.2 10 08/20/2005 18:30:00 6.6 0.7 8.4 4.2 6 0.7 7.6 4.2 235 6 241 305 9.9 0 10 9.7 08/20/2005 18:40:00 6.7 0.6 8.4 4.6 5.9 0.6 7.6 4.2 239 6 236 305 9.9 0 10 9.7 08/20/2005 18:50:00 7.8 0.7 9.1 5.7 7 0.7 8.8 4.9 241 5 244 305 10 0 10.2 9.7 08/20/2005 19:00:00 6.7 0.9 8.8 4.9 5.9 0.9 8 3.8 244 6 241 305 9.9 0 10 10 08/20/2005 19:10:00 6.3 0.6 8 3.8 5.8 0.7 7.6 4.2 249 8 259 305 10 0 10.2 10 08/20/2005 19:20:00 6.6 1 8.8 3.4 6 0.9 8 3.8 248 8 250 305 10.1 0 10.2 10 08/20/2005 19:30:00 6.5 0.6 8.4 4.9 5.9 0.6 8 4.2 242 5 244 305 10.2 0 10.2 10 08/20/2005 19:40:00 6.7 0.7 8.8 4.6 5.8 0.8 8.4 3.8 245 7 256 305 10.2 0 10.2 10 08/20/2005 19:50:00 6.4 0.7 8 4.6 5.6 0.8 7.6 3.8 249 6 250 305 10.2 0 10.2 10.2 08/20/2005 20:00:00 7.1 0.8 8.8 5.3 6.5 0.8 8 4.2 248 5 246 305 10.2 0 10.2 10.2 08/20/2005 20:10:00 6.8 0.8 8.4 4.6 6.1 1 8 3.8 247 6 253 305 10.3 0 10.5 10.2 08/20/2005 20:20:00 6.6 0.7 8 4.2 5.9 0.9 8.4 3.8 247 6 244 305 10.4 0 10.5 10.2 08/20/2005 20:30:00 6.2 0.7 8 4.2 5.5 0.7 7.2 3.8 245 6 245 305 10.6 0 10.8 10.5 08/20/2005 20:40:00 6.3 0.7 8 4.2 5.6 0.8 7.6 3 251 7 252 305 10.2 0 10.5 10.2 08/20/2005 20:50:00 6.1 0.7 7.6 4.2 5.4 0.9 7.2 3 255 7 255 305 10.2 0 10.2 10.2 08/20/2005 21:00:00 6.2 0.7 8 4.2 5.2 0.7 7.2 3.4 260 6 258 305 10.2 0 10.2 10.2 08/20/2005 21:10:00 6.1 0.9 8 3.8 4.9 0.8 6.8 2.6 261 7 271 305 10.2 0 10.2 10.2 08/20/2005 21:20:00 5.5 0.5 6.8 4.2 4.8 0.6 6.1 3.4 256 6 263 305 10 0 10.2 10 08/20/2005 21:30:00 5.4 0.5 6.5 3.8 4.8 0.6 6.5 3 253 6 254 305 9.9 0 10 10 08/20/2005 21:40:00 5.5 0.6 6.8 4.2 4.8 0.6 6.5 3.4 254 6 262 305 9.9 0 10 9.7 08/20/2005 21:50:00 5.3 0.6 6.8 3.4 4.6 0.6 6.5 3 254 7 262 305 9.9 0 10 9.7 08/20/2005 22:00:00 4.6 0.4 5.7 3.4 4.1 0.4 5.3 3 248 5 248 305 9.8 0 10 9.7 08/20/2005 22:10:00 4.6 0.5 5.7 2.6 4.1 0.5 5.3 2.6 246 7 245 305 9.7 0 10 9.7 08/20/2005 22:20:00 4.9 0.5 6.1 3.4 4.4 0.5 5.7 3 239 6 246 305 9.9 0 10 9.7 08/20/2005 22:30:00 5.5 0.5 6.5 4.2 4.9 0.5 6.1 3.4 231 5 236 305 9.9 0 10 9.7 08/20/2005 22:40:00 5.1 0.4 6.1 4.2 4.8 0.4 5.7 3.4 223 6 225 305 9.9 0 10 9.7 08/20/2005 22:50:00 5.3 0.6 6.8 3 4.9 0.6 6.5 3.4 216 7 220 305 9.9 0 10 9.7 08/20/2005 23:00:00 5.8 0.6 7.6 4.6 5.3 0.5 7.2 3.8 223 8 231 305 9.9 0 10 9.7 08/20/2005 23:10:00 6.2 0.5 7.6 4.9 5.6 0.5 6.8 4.2 226 5 234 305 10 0 10.2 10 08/20/2005 23:20:00 5.2 0.7 6.8 3.4 4.8 0.6 6.5 3 219 7 212 305 10.1 0 10.2 10 08/20/2005 23:30:00 5.9 0.8 7.6 3.4 5.3 0.7 6.8 3.4 223 9 218 305 10 0 10.2 10 08/20/2005 23:40:00 6.8 0.6 8.4 4.9 6.2 0.6 7.6 4.6 233 6 241 305 10 0 10.2 10 08/20/2005 23:50:00 7 0.7 8.4 5.3 6.3 0.6 8 4.9 240 6 242 305 10.1 0 10.2 10 08/21/2005 00:00:00 7.1 0.6 8.8 4.9 6.1 0.6 7.6 3.8 246 6 256 305 10.1 0 10.8 10 08/21/2005 00:10:00 6.9 0.5 8.4 5.7 6.2 0.6 8 4.2 247 6 248 305 10.1 0 10.2 10 08/21/2005 00:20:00 6.5 0.7 8 4.6 5.6 0.9 7.6 3.4 254 7 250 305 10.1 0 10.2 10 08/21/2005 00:30:00 6.6 0.7 8 4.6 5.5 0.8 7.6 3.4 257 6 262 305 10.2 0 10.2 10 08/21/2005 00:40:00 6.1 0.7 7.6 4.6 4.9 0.8 6.8 3 260 8 269 305 10.2 0 10.2 10.2 08/21/2005 00:50:00 5.8 0.9 7.6 3 4.4 0.8 6.5 2.3 269 8 272 305 10.2 0 10.2 10.2 08/21/2005 01:00:00 6.7 0.7 8.4 4.6 5.3 0.8 7.2 3.4 273 8 273 305 10.3 0 10.5 10.2 08/21/2005 01:10:00 6.8 0.9 8.8 3.8 5.2 1 7.6 2.6 271 8 275 305 10.4 0 10.5 10.2 08/21/2005 01:20:00 6.5 0.7 8.4 4.2 5 0.6 6.8 3.4 270 7 270 305 10.4 0 10.5 10.2 08/21/2005 01:30:00 6.3 0.7 8.4 4.2 4.9 0.7 7.2 3 265 7 269 305 10.4 0 10.5 10.2 08/21/2005 01:40:00 6.1 0.6 7.6 4.2 4.9 0.7 6.8 3 263 6 262 305 10.4 0 10.5 10.2 08/21/2005 01:50:00 5.7 0.6 6.8 3.4 4.7 0.6 6.1 2.6 260 6 264 305 10.4 0 10.5 10.2 08/21/2005 02:00:00 5.7 0.6 7.2 4.2 4.8 0.7 6.5 3.4 260 7 259 305 10.5 0 10.5 10.2 08/21/2005 02:10:00 5.7 0.7 8 3.8 4.7 0.7 6.1 2.6 261 6 266 305 10.5 0 10.8 10.5 08/21/2005 02:20:00 5.4 0.6 7.6 3.8 4.6 0.6 6.1 2.6 256 8 266 305 10.5 0 10.5 10.5 08/21/2005 02:30:00 5.2 0.5 6.5 3.8 4.6 0.5 5.7 3.4 248 5 253 305 10.4 0 10.5 10.2 08/21/2005 02:40:00 5.3 0.4 6.1 4.2 4.7 0.4 5.7 3.8 243 5 242 305 10.4 0 10.5 10.2 08/21/2005 02:50:00 5.2 0.4 6.1 4.2 4.7 0.4 5.7 3.8 241 5 241 305 10.3 0 10.5 10.2 08/21/2005 03:00:00 5.5 0.5 7.6 3.8 4.9 0.5 6.8 3.8 236 6 242 305 10.3 0 10.5 10.2 08/21/2005 03:10:00 5.7 0.4 6.8 4.6 5.1 0.4 6.1 4.2 235 5 228 305 10.4 0 10.5 10.2 08/21/2005 03:20:00 5.9 0.4 6.8 4.6 5.3 0.5 6.5 3.8 232 4 236 305 10.4 0 10.5 10.2 08/21/2005 03:30:00 5.9 0.5 7.2 4.6 5.1 0.5 6.5 3.8 231 5 235 305 10.3 0 10.5 10.2 08/21/2005 03:40:00 6.1 0.6 7.6 4.2 5.3 0.6 6.8 3.8 234 6 234 305 10.3 0 10.5 10.2 08/21/2005 03:50:00 6.2 0.5 7.2 4.9 5.6 0.5 6.8 4.2 235 5 232 305 10.2 0 10.2 10 08/21/2005 04:00:00 5.8 0.5 6.8 4.2 5.1 0.5 6.1 3.8 234 5 231 305 10.1 0 10.2 10 08/21/2005 04:10:00 6.2 0.7 8 4.6 5.5 0.7 7.2 4.2 234 6 234 305 10.2 0 10.2 10 08/21/2005 04:20:00 6.5 0.5 8 4.6 5.8 0.6 7.2 4.2 233 6 235 305 10.2 0 10.2 10 08/21/2005 04:30:00 7.3 0.7 9.1 5.3 6.3 0.7 8 4.6 236 6 241 305 10.1 0 10.2 10 08/21/2005 04:40:00 7.7 0.6 9.1 6.1 6.7 0.7 8.8 4.9 237 6 231 305 10.2 0 10.2 10 08/21/2005 04:50:00 8.1 0.6 9.9 6.1 7.4 0.6 9.1 5.3 233 5 241 305 10.2 0 10.2 10.2 08/21/2005 05:00:00 8.5 0.6 9.9 6.8 7.6 0.6 9.1 6.1 241 5 243 305 10.2 0 10.2 10.2 08/21/2005 05:10:00 8.1 0.6 9.9 6.1 7.3 0.7 9.1 4.6 244 5 245 305 10.2 0 10.2 10.2 08/21/2005 05:20:00 7.6 0.6 9.1 6.1 6.8 0.7 8.4 5.3 242 5 248 305 10.1 0 10.2 10 08/21/2005 05:30:00 6.7 0.7 8.8 4.6 6 0.7 7.6 4.2 237 6 242 305 10 0 10.2 10 08/21/2005 05:40:00 8.1 0.7 9.9 6.1 7.3 0.8 9.1 5.3 232 5 235 305 10 0 10.2 9.7 08/21/2005 05:50:00 9 0.8 10.7 6.8 8.1 0.9 10.3 6.1 234 5 236 305 9.8 0 10 9.7 08/21/2005 06:00:00 8.1 0.9 11.1 6.1 7.3 0.9 10.3 4.9 233 6 241 305 9.7 0 9.7 9.7 08/21/2005 06:10:00 8.2 0.7 9.9 6.1 7.5 0.9 9.1 5.3 230 5 228 305 9.7 0 9.7 9.5 08/21/2005 06:20:00 8.3 0.9 10.7 5.3 7.5 0.9 9.9 5.3 230 5 237 305 9.7 0 9.7 9.5 08/21/2005 06:30:00 8.3 0.8 10.7 6.1 7.3 1 9.9 5.3 226 6 231 305 9.7 0 9.7 9.5 08/21/2005 06:40:00 7.4 0.7 8.8 5.3 6.5 0.8 8.8 4.6 225 5 232 305 9.7 0 10 9.5 08/21/2005 06:50:00 7.4 0.5 8.8 5.7 6.8 0.6 8.4 4.9 221 5 221 305 9.7 0 9.7 9.7 08/21/2005 07:00:00 7.6 0.6 9.1 5.7 7 0.6 8.8 4.9 218 5 219 305 9.7 0 9.7 9.7 08/21/2005 07:10:00 7 0.6 8.8 4.9 6.4 0.6 8 4.9 215 6 217 305 9.7 0 9.7 9.7 08/21/2005 07:20:00 6.6 0.8 8 4.2 6.1 0.8 8 3.8 213 6 217 305 9.7 0 10 9.7 08/21/2005 07:30:00 6.4 0.7 8 4.6 5.9 0.6 7.6 4.2 214 6 220 305 9.7 0 10 9.7 08/21/2005 07:40:00 6.2 0.5 7.6 4.9 6 0.6 7.2 4.2 207 6 205 305 9.8 0 10 9.7 08/21/2005 07:50:00 6.8 0.5 8 5.7 6.5 0.5 8 5.3 209 5 211 305 9.9 0 10 9.7 08/21/2005 08:00:00 7.2 0.5 8.4 5.7 7 0.6 8.4 4.9 202 5 198 305 9.9 0 10 9.7 08/21/2005 08:10:00 6.7 0.5 8.4 5.3 6.5 0.6 8 4.9 196 4 203 305 9.8 0 10 9.7 08/21/2005 08:20:00 6.8 0.5 8 5.3 6.8 0.5 8.4 5.3 190 5 181 305 9.7 0 10 9.7 08/21/2005 08:30:00 7 0.8 8.8 4.6 7.8 0.8 9.5 5.7 183 5 183 305 9.8 0 10 9.7 08/21/2005 08:40:00 7.9 0.5 9.1 5.7 8 0.5 9.1 5.7 190 6 200 305 9.7 0 10 9.7 08/21/2005 08:50:00 8.7 0.6 9.9 7.2 8.4 0.6 9.9 7.2 203 4 206 305 9.8 0 10 9.7 08/21/2005 09:00:00 8.8 0.5 9.9 7.2 8.4 0.7 9.9 5.7 203 5 203 305 10 0 10 9.7 08/21/2005 09:10:00 8.7 0.6 10.3 6.8 8.3 0.7 9.9 6.1 209 4 211 305 10 0 10.2 10 08/21/2005 09:20:00 8.4 0.5 9.9 6.8 8.1 0.6 9.5 6.1 205 4 210 305 10 0 10.2 10 08/21/2005 09:30:00 8.1 0.5 9.1 6.5 7.8 0.5 9.1 6.5 205 4 213 305 10 0 10.2 10 08/21/2005 09:40:00 8.3 0.5 9.5 6.8 8 0.5 9.1 6.5 206 4 206 305 10.3 0 10.5 10.2 08/21/2005 09:50:00 8.4 0.5 9.9 6.8 8.1 0.6 9.5 6.5 204 4 205 305 10.4 0 10.5 10.2 08/21/2005 10:00:00 8.6 0.4 9.9 7.2 8.3 0.5 9.5 6.1 208 3 204 305 10.6 0 10.8 10.5 08/21/2005 10:10:00 8.7 0.5 10.3 6.8 8.5 0.6 9.9 6.8 206 4 213 305 10.7 0 10.8 10.5 08/21/2005 10:20:00 8.6 0.5 9.9 6.8 8.3 0.5 9.9 6.5 207 6 214 305 10.8 0 11 10.8 08/21/2005 10:30:00 8.1 0.5 9.1 6.1 7.9 0.6 9.1 6.1 198 4 199 305 10.8 0 10.8 10.5 08/21/2005 10:40:00 8.6 0.4 9.5 7.2 8.2 0.6 9.5 6.1 206 4 208 305 10.9 0 11 10.8 08/21/2005 10:50:00 8.2 0.5 9.1 6.8 8 0.5 9.1 6.1 201 4 206 305 11 0 11 10.8 08/21/2005 11:00:00 8.1 0.5 9.5 6.8 7.9 0.6 9.1 5.7 200 4 194 305 10.8 0 11 10.8 08/21/2005 11:10:00 8.7 0.7 10.3 6.8 8.5 0.8 10.3 6.5 200 3 205 305 10.9 0 11 10.8 08/21/2005 11:20:00 9.9 0.5 11.1 7.6 9.5 0.8 10.7 6.8 207 4 214 305 10.9 0 11 10.8 08/21/2005 11:30:00 9.5 0.7 11.1 6.8 8.8 0.8 10.7 6.1 215 5 214 305 11.2 0 11.3 11 08/21/2005 11:40:00 8.4 0.8 10.3 6.1 7.9 0.8 9.9 6.1 221 5 217 305 11.4 0 11.6 11.3 08/21/2005 11:50:00 8.1 0.6 9.5 6.1 7.5 0.8 9.1 5.3 221 5 217 305 11.8 0 11.8 11.3 08/21/2005 12:00:00 7.8 0.6 9.5 5.7 7.1 0.8 9.1 4.9 216 6 210 305 12 0 12.1 11.8 08/21/2005 12:10:00 8.1 0.8 9.9 5.7 7.9 1 9.9 5.7 206 7 198 305 11.8 0.2 12.1 11.3 08/21/2005 12:20:00 8 0.8 9.5 5.7 7.7 0.9 9.5 5.3 210 5 208 305 11.2 0 11.6 11 08/21/2005 12:30:00 8.2 0.6 9.9 6.5 8 0.6 9.5 6.1 206 5 206 305 11.4 0 11.6 11.3 08/21/2005 12:40:00 7.4 0.5 8.4 5.3 7.2 0.6 8.4 4.9 208 5 211 305 11.7 0 11.8 11.3 08/21/2005 12:50:00 7.3 0.5 8.8 5.7 7.1 0.5 8.4 6.1 204 5 208 305 12 0 12.1 11.8 08/21/2005 13:00:00 7.2 0.7 9.1 4.9 6.7 0.9 8.8 4.2 216 6 213 305 12.4 0.1 12.6 12.1 08/21/2005 13:10:00 7.3 0.8 8.8 4.9 6.7 0.8 8.4 4.9 219 6 216 305 12.6 0 12.9 12.4 08/21/2005 13:20:00 7.4 0.7 9.1 4.9 6.8 0.8 8.8 4.9 222 6 216 305 12.9 0.1 13.2 12.6 08/21/2005 13:30:00 7.6 0.8 9.5 5.7 7.1 0.9 9.1 4.6 222 7 230 305 13 0 13.2 12.9 08/21/2005 13:40:00 7.5 0.7 9.5 5.7 7 0.8 9.1 4.9 224 7 228 305 13.1 0 13.4 13.2 08/21/2005 13:50:00 7.4 0.7 9.1 5.7 7.1 0.8 9.1 4.9 220 6 223 305 13.1 0 13.4 12.9 08/21/2005 14:00:00 8 0.7 9.5 6.1 7.4 0.8 9.1 4.9 216 6 224 305 13 0 13.2 12.9 08/21/2005 14:10:00 8 0.7 9.5 5.7 7.6 0.7 9.1 5.7 218 6 225 305 13 0 13.2 12.9 08/21/2005 14:20:00 7.6 0.8 9.5 5.7 7 0.8 8.8 4.9 215 7 213 305 13 0 13.2 12.9 08/21/2005 14:30:00 7.1 0.8 8.8 4.9 6.6 0.9 8.4 4.6 213 6 226 305 13 0 13.2 12.9 08/21/2005 14:40:00 7.8 0.6 9.1 5.3 7.6 0.7 8.8 5.3 206 5 206 305 12.8 0 13.2 12.4 08/21/2005 14:50:00 7.1 0.6 8.8 5.3 7 0.7 8.4 4.9 205 6 208 305 12.4 0 12.4 12.1 08/21/2005 15:00:00 7.1 0.8 9.1 4.6 6.8 0.8 8.8 4.6 212 6 208 305 12.4 0 12.6 12.1 08/21/2005 15:10:00 7.2 0.6 8.4 4.6 7 0.6 8.4 4.6 206 5 209 305 12.4 0.2 12.9 12.1 08/21/2005 15:20:00 7.1 0.6 8.4 5.3 6.9 0.6 8.4 5.3 205 5 208 305 12.1 0 12.4 11.8 08/21/2005 15:30:00 6.9 0.7 8.4 4.6 6.6 0.8 8.8 4.6 199 7 208 305 12 0 12.1 11.8 08/21/2005 15:40:00 7.5 0.7 9.1 5.3 7.5 0.8 9.1 4.9 191 4 192 305 12 0 12.1 11.8 08/21/2005 15:50:00 7.3 0.6 8.8 5.3 7.1 0.7 8.8 5.3 193 4 198 305 12.2 0 12.4 11.8 08/21/2005 16:00:00 7.2 0.4 8.4 6.1 7.1 0.5 8.4 5.3 194 5 194 305 12.1 0 12.4 11.8 08/21/2005 16:10:00 7 0.5 8 4.9 6.8 0.5 8 5.3 198 4 192 305 12.2 0 12.4 12.1 08/21/2005 16:20:00 7.3 0.4 8 5.7 7.1 0.5 8.4 5.7 201 3 200 305 12.1 0 12.1 11.8 08/21/2005 16:30:00 7.3 0.4 8.4 5.7 7.1 0.5 8.4 5.3 198 5 205 305 12 0 12.1 11.8 08/21/2005 16:40:00 6.7 0.7 8.4 4.6 6.5 0.7 8 4.6 207 6 194 305 12 0.1 12.4 11.8 08/21/2005 16:50:00 6.1 0.6 7.6 4.6 6 0.6 7.6 4.6 205 7 211 305 12 0 12.4 11.8 08/21/2005 17:00:00 6.1 0.5 7.6 4.9 6 0.5 7.6 4.6 198 7 206 305 11.9 0 11.8 11.6 08/21/2005 17:10:00 6 0.5 6.8 4.2 5.8 0.6 7.2 3.8 200 6 200 305 12 0 12.1 11.8 08/21/2005 17:20:00 6.6 0.6 7.6 4.9 6.4 0.7 8 4.9 200 7 200 305 12.2 0 12.4 12.1 08/21/2005 17:30:00 6.6 0.5 8.4 4.9 6.4 0.5 8 4.6 205 7 203 305 12.2 0 12.4 11.8 08/21/2005 17:40:00 6.5 0.6 8 4.6 6.3 0.7 7.6 4.2 198 8 192 305 12.1 0.1 12.4 11.8 08/21/2005 17:50:00 6.4 0.6 7.6 4.6 6.3 0.7 8 4.2 196 6 193 305 12.1 0 12.4 11.8 08/21/2005 18:00:00 6.5 0.5 8 4.9 6.4 0.5 7.6 4.9 193 5 195 305 12 0 12.1 11.8 08/21/2005 18:10:00 6.8 0.5 8 5.3 6.6 0.7 8.4 4.6 198 6 197 305 11.9 0 12.1 11.6 08/21/2005 18:20:00 6.7 0.6 8 4.2 6.5 0.7 8 3.8 197 5 200 305 11.7 0 11.8 11.6 08/21/2005 18:30:00 7.3 0.6 8.8 5.3 7.2 0.6 8.8 4.9 195 5 200 305 11.7 0 11.8 11.6 08/21/2005 18:40:00 8.1 0.6 9.5 6.5 8 0.7 9.1 6.1 197 6 198 305 11.4 0 11.6 11.3 08/21/2005 18:50:00 8.1 0.6 9.5 5.7 7.9 0.6 9.5 6.1 200 4 196 305 11.2 0 11.3 11 08/21/2005 19:00:00 8.2 0.5 9.1 6.5 8 0.6 9.5 6.1 200 4 202 305 11.1 0 11.3 11 08/21/2005 19:10:00 8 0.6 9.1 5.3 7.8 0.7 9.5 5.7 196 4 193 305 11 0.1 11.3 10.8 08/21/2005 19:20:00 7.7 0.6 9.1 6.1 7.5 0.7 9.1 5.3 194 4 197 305 11 0 11.3 11 08/21/2005 19:30:00 8.2 0.6 9.9 6.1 8.1 0.7 9.5 5.7 193 4 203 305 11 0 11.3 10.8 08/21/2005 19:40:00 8.6 0.6 9.9 5.7 8.5 0.7 9.9 5.7 193 4 194 305 10.9 0 11 10.8 08/21/2005 19:50:00 8.8 0.7 10.3 6.8 8.7 0.8 10.7 6.1 195 4 190 305 10.7 0.2 11 10.2 08/21/2005 20:00:00 9.3 0.6 10.7 7.2 9.3 0.7 11.1 6.8 194 4 196 305 9.5 0.2 10.2 9.2 08/21/2005 20:10:00 9.7 0.6 11.1 8 9.7 0.9 11.5 6.5 193 4 193 305 9.1 0 9.2 8.9 08/21/2005 20:20:00 9.5 0.7 11.1 7.6 9.4 0.9 11.5 6.8 192 4 192 305 9.1 0 9.2 8.9 08/21/2005 20:30:00 8.5 0.8 10.3 6.1 8.5 1 10.7 5.7 190 4 190 305 9.2 0 9.5 9.2 08/21/2005 20:40:00 9.1 0.8 10.7 6.5 9.3 1 11.1 6.1 188 4 190 305 9.2 0 9.5 9.2 08/21/2005 20:50:00 9.2 0.7 10.7 6.8 9.1 0.9 10.7 6.5 192 4 190 305 9.1 0 9.2 8.9 08/21/2005 21:00:00 9.3 0.5 10.7 7.6 9.4 0.6 10.7 7.6 190 4 193 305 8.9 0 9.2 8.9 08/21/2005 21:10:00 9.3 0.6 10.7 7.2 9.3 0.7 11.1 7.2 191 5 189 305 8.9 0 9.2 8.9 08/21/2005 21:20:00 10.4 0.7 11.8 8 10.2 0.8 11.8 7.2 195 3 196 305 8.8 0.1 8.9 8.7 08/21/2005 21:30:00 9.4 0.9 11.5 6.8 9.3 1 11.5 6.8 194 4 194 305 8.8 0 8.9 8.7 08/21/2005 21:40:00 9.3 0.8 11.1 6.8 9.1 1 11.1 6.5 193 4 193 305 8.8 0 8.9 8.7 08/21/2005 21:50:00 9.1 0.8 11.1 6.5 8.9 1 10.7 6.1 192 4 194 305 8.8 0 8.9 8.7 08/21/2005 22:00:00 8 0.6 9.9 6.5 8 0.8 10.3 5.7 193 5 190 305 8.7 0 8.9 8.4 08/21/2005 22:10:00 7.4 0.5 8.4 5.7 7.3 0.7 8.8 5.3 195 5 194 305 8.6 0 8.7 8.4 08/21/2005 22:20:00 7 0.5 8 4.9 7 0.7 8.4 4.9 193 5 192 305 8.6 0 8.7 8.4 08/21/2005 22:30:00 7.3 0.7 8.8 5.3 7.8 0.6 9.5 6.1 185 4 183 305 8.5 0 8.7 8.4 08/21/2005 22:40:00 8.2 0.8 9.9 5.7 8.1 0.8 9.9 6.1 197 6 198 305 8.4 0 8.4 8.2 08/21/2005 22:50:00 8.9 0.5 9.9 6.8 8.8 0.6 9.9 6.5 202 4 203 305 8.3 0 8.4 8.2 08/21/2005 23:00:00 7.9 0.5 8.8 6.5 8 0.6 9.1 5.3 192 5 198 305 8.4 0 8.4 8.2 08/21/2005 23:10:00 6.6 0.7 8.4 4.6 6.9 0.8 8.4 4.2 187 5 199 305 8.5 0 8.7 8.4 08/21/2005 23:20:00 7.5 0.6 8.8 6.1 7.5 0.7 9.1 5.7 199 5 199 305 8.6 0 8.7 8.4 08/21/2005 23:30:00 8.1 0.5 9.1 5.7 8 0.6 9.1 6.1 206 4 210 305 8.6 0 8.7 8.4 08/21/2005 23:40:00 8.3 0.5 9.1 6.5 8.3 0.5 9.5 6.5 200 5 201 305 8.6 0 8.7 8.4 08/21/2005 23:50:00 7.7 0.6 8.8 5.7 7.6 0.8 8.8 5.3 196 5 198 305 8.6 0 8.9 8.4 08/22/2005 00:00:00 7.8 0.6 9.5 5.7 7.9 0.7 9.1 5.7 193 4 189 305 8.7 0 9.2 8.7 08/22/2005 00:10:00 8 0.6 9.1 6.1 7.9 0.8 9.5 5.7 193 4 190 305 8.7 0 8.9 8.4 08/22/2005 00:20:00 8.7 0.6 9.9 6.5 8.7 0.8 10.3 6.1 193 4 194 305 8.6 0 8.9 8.4 08/22/2005 00:30:00 8.7 0.6 10.3 6.8 8.6 0.7 9.9 6.5 193 4 191 305 8.6 0 8.7 8.4 08/22/2005 00:40:00 8.2 0.7 9.5 5.7 8.3 0.8 9.9 6.1 196 4 197 305 8.6 0 8.7 8.4 08/22/2005 00:50:00 7.8 0.6 9.1 6.1 7.8 0.6 9.1 6.1 202 3 201 305 8.6 0 8.7 8.4 08/22/2005 01:00:00 8.5 0.6 9.5 6.1 8.4 0.7 9.9 6.1 199 4 202 305 8.6 0 8.7 8.4 08/22/2005 01:10:00 7.9 0.7 9.5 5.7 7.8 0.8 9.5 4.9 197 4 192 305 8.6 0 8.9 8.4 08/22/2005 01:20:00 8.1 0.5 9.1 6.5 8.1 0.7 9.5 6.1 199 3 186 305 8.6 0 8.7 8.4 08/22/2005 01:30:00 7.8 0.4 9.1 6.8 7.8 0.5 9.1 6.1 201 4 199 305 8.6 0 8.7 8.4 08/22/2005 01:40:00 8 0.4 8.8 6.8 8.1 0.5 9.5 6.8 202 3 197 305 8.5 0 8.7 8.4 08/22/2005 01:50:00 8 0.7 10.3 6.1 8.1 0.7 9.9 6.1 199 5 198 305 8.6 0 8.7 8.4 08/22/2005 02:00:00 8.1 0.8 9.5 5.3 8 0.9 9.9 5.3 195 5 192 305 8.6 0 8.7 8.4 08/22/2005 02:10:00 8 0.7 9.9 6.1 7.9 0.8 9.9 5.7 195 5 205 305 8.6 0 8.7 8.4 08/22/2005 02:20:00 8.6 0.6 9.9 6.5 8.6 0.7 10.3 6.1 195 4 194 305 8.6 0 8.7 8.4 08/22/2005 02:30:00 9 0.5 10.3 7.6 9 0.6 10.7 6.1 195 4 198 305 8.6 0 8.7 8.4 08/22/2005 02:40:00 8.1 0.7 9.9 5.7 8.1 0.9 9.9 5.3 192 5 191 305 8.6 0 8.7 8.4 08/22/2005 02:50:00 7.7 0.6 8.8 6.1 7.6 0.7 9.1 5.3 194 5 187 305 8.6 0 8.7 8.4 08/22/2005 03:00:00 7.1 0.6 8.4 4.9 7.1 0.6 8.8 5.3 192 5 203 305 8.6 0 8.7 8.4 08/22/2005 03:10:00 7.5 0.6 8.8 5.7 7.4 0.7 8.8 5.3 194 6 184 305 8.6 0 8.7 8.4 08/22/2005 03:20:00 7.2 0.6 8.8 5.3 7.3 0.6 9.1 5.3 196 4 201 305 8.4 0 8.7 8.4 08/22/2005 03:30:00 7.4 0.7 9.1 5.3 7.4 0.8 9.1 5.3 199 6 214 305 8.6 0 8.9 8.4 08/22/2005 03:40:00 7.1 0.6 8.8 4.9 7.1 0.7 8.8 4.6 197 5 196 305 8.6 0 8.7 8.4 08/22/2005 03:50:00 7.2 0.7 9.1 4.6 7.1 0.8 8.8 4.9 194 6 204 305 8.6 0 8.9 8.4 08/22/2005 04:00:00 7.2 0.6 8.8 5.3 7.1 0.7 8.8 4.6 192 4 192 305 8.6 0 8.7 8.4 08/22/2005 04:10:00 7.1 0.6 8.4 5.3 7 0.7 8.4 5.3 201 8 198 305 8.6 0 8.7 8.4 08/22/2005 04:20:00 6.4 0.5 7.6 4.6 6.3 0.7 8 4.6 209 5 203 305 8.7 0 8.9 8.7 08/22/2005 04:30:00 7 0.6 8.4 5.3 6.8 0.7 8.4 4.9 216 6 215 305 8.7 0 8.9 8.4 08/22/2005 04:40:00 6.6 0.6 8 4.6 6.6 0.6 8 4.6 207 7 227 305 8.8 0 8.9 8.7 08/22/2005 04:50:00 6.9 0.4 7.6 4.9 6.9 0.5 8.4 5.3 203 6 205 305 8.8 0 8.9 8.7 08/22/2005 05:00:00 6.8 0.6 8 4.6 6.7 0.7 8 4.6 199 8 204 305 8.8 0 8.9 8.7 08/22/2005 05:10:00 6.2 0.6 8 4.2 6.1 0.7 8 4.2 207 6 202 305 8.7 0 8.9 8.7 08/22/2005 05:20:00 5.9 0.7 7.6 3.8 5.8 0.7 7.6 4.2 200 8 194 305 8.8 0 8.9 8.7 08/22/2005 05:30:00 5 0.6 6.5 3.4 5.1 0.6 6.5 3.4 194 6 195 305 8.8 0 8.9 8.7 08/22/2005 05:40:00 4.6 0.5 6.1 3 4.7 0.6 6.1 3 197 10 205 305 8.8 0 8.9 8.7 08/22/2005 05:50:00 4 0.9 6.5 1.9 4.6 1 7.2 2.3 189 13 181 305 8.8 0 8.9 8.7 08/22/2005 06:00:00 3.5 0.8 5.3 1.5 4.5 0.6 6.1 3 181 7 189 305 8.6 0 8.9 8.7 08/22/2005 06:10:00 3.7 0.7 5.7 1.9 4.4 0.6 5.7 2.6 182 5 195 305 8.6 0 8.7 8.4 08/22/2005 06:20:00 3.8 0.7 5.3 1.9 4.3 0.6 5.7 2.6 185 6 196 305 8.6 0 8.7 8.4 08/22/2005 06:30:00 3.8 0.8 5.7 1.9 4.1 0.7 6.1 2.3 189 8 188 305 8.6 0 8.7 8.4 08/22/2005 06:40:00 3.5 0.6 4.9 1.1 4.1 0.4 4.9 3 183 5 193 305 8.6 0 8.7 8.4 08/22/2005 06:50:00 3.7 0.5 4.9 1.9 4 0.5 4.9 2.3 187 5 186 305 8.4 0 8.4 8.4 08/22/2005 07:00:00 3.4 0.5 4.2 1.9 4 0.4 4.9 3 181 4 186 305 8.4 0 8.4 8.4 08/22/2005 07:10:00 3.4 0.5 4.6 2.3 3.9 0.3 4.6 3 182 4 186 305 8.4 0 8.4 8.4 08/22/2005 07:20:00 3.2 0.5 4.2 1.9 3.6 0.4 4.9 2.6 183 4 184 305 8.4 0 8.4 8.4 08/22/2005 07:30:00 2.6 0.6 4.6 1.1 3.5 0.5 4.6 2.3 176 6 186 305 8.4 0 8.4 8.4 08/22/2005 07:40:00 2.8 0.6 3.8 1.1 3.5 0.4 4.2 2.3 181 5 186 305 8.5 0 8.7 8.4 08/22/2005 07:50:00 2.3 0.5 3.4 1.1 3.4 0.5 4.6 1.9 173 7 185 305 8.5 0 8.7 8.4 08/22/2005 08:00:00 2.7 0.6 3.8 1.1 3.4 0.4 4.6 1.5 165 10 160 305 8.5 0 8.7 8.4 08/22/2005 08:10:00 3 0.5 4.2 1.5 3.2 0.4 4.2 2.3 150 8 152 305 8.5 0 8.7 8.4 08/22/2005 08:20:00 2.8 0.5 3.8 1.1 2.9 0.4 3.8 1.9 150 9 134 305 8.4 0 8.7 8.4 08/22/2005 08:30:00 3 0.4 3.8 1.9 3.1 0.4 3.8 1.9 143 5 143 305 8.5 0 8.4 8.4 08/22/2005 08:40:00 3.6 0.7 4.6 1.9 3.6 0.7 4.9 2.3 140 6 139 305 8.5 0 8.7 8.2 08/22/2005 08:50:00 4.4 0.3 4.9 3 4.4 0.3 4.9 3.4 134 3 132 305 8.3 0 8.4 8.2 08/22/2005 09:00:00 4.5 0.3 4.9 3.4 4.5 0.3 4.9 3.4 132 5 134 305 8.4 0 8.4 8.2 08/22/2005 09:10:00 3.5 0.5 4.6 2.3 3.5 0.4 4.6 2.3 123 7 124 305 8.5 0 8.7 8.4 08/22/2005 09:20:00 3.5 0.4 4.2 2.6 3.6 0.4 4.6 2.6 117 5 113 305 8.6 0 8.9 8.4 08/22/2005 09:30:00 3.1 0.5 4.2 1.9 3.1 0.5 4.2 2.3 120 7 118 305 8.8 0 9.2 8.7 08/22/2005 09:40:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 126 8 128 305 9.1 0 9.2 8.9 08/22/2005 09:50:00 3.4 0.5 4.6 2.3 3.5 0.5 4.6 1.9 125 8 123 305 9.3 0.1 9.5 9.2 08/22/2005 10:00:00 3.7 0.5 5.3 2.3 3.8 0.5 4.9 2.6 124 8 114 305 9.3 0 9.5 9.2 08/22/2005 10:10:00 4.1 0.5 5.3 3 4.1 0.5 5.7 2.6 137 6 129 305 9.3 0 9.5 9.2 08/22/2005 10:20:00 4.9 0.7 6.1 3 4.8 0.6 6.1 3 134 7 146 305 9.2 0 9.5 9.2 08/22/2005 10:30:00 4.1 0.5 5.3 2.3 4.1 0.5 4.9 2.6 135 7 129 305 9.3 0 9.5 9.2 08/22/2005 10:40:00 4.4 0.6 5.7 3 4.5 0.6 5.7 3 137 7 137 305 9.6 0 9.7 9.5 08/22/2005 10:50:00 4.1 0.6 5.7 2.6 4.2 0.6 5.7 2.6 131 11 131 305 9.8 0 10 9.7 08/22/2005 11:00:00 4.6 0.5 5.7 3.4 4.5 0.5 5.7 2.6 115 8 123 305 9.8 0 10 9.7 08/22/2005 11:10:00 3.4 0.6 4.9 2.3 3.4 0.5 4.9 2.3 123 16 108 305 9.7 0 10 9.7 08/22/2005 11:20:00 2.7 0.7 4.9 1.1 2.8 0.7 4.6 1.5 121 23 121 305 9.9 0 10 9.7 08/22/2005 11:30:00 3.6 0.5 4.6 2.3 3.6 0.6 4.9 1.9 131 15 108 305 9.7 0 10 9.5 08/22/2005 11:40:00 3.1 0.5 4.6 1.9 3.1 0.4 4.2 1.9 136 10 141 305 9.5 0 9.7 9.5 08/22/2005 11:50:00 3.7 0.6 5.7 2.3 3.7 0.5 5.3 2.6 136 9 138 305 9.9 0 10 9.7 08/22/2005 12:00:00 3.2 0.6 4.9 1.5 3.2 0.6 4.9 1.9 130 10 135 305 9.9 0 10.2 9.7 08/22/2005 12:10:00 1.5 0.8 3.8 0.4 1.6 0.7 3.8 0.4 134 22 135 305 9.7 0 9.7 9.5 08/22/2005 12:20:00 1.7 0.8 3.4 0.4 1.9 0.7 3.8 0.4 122 38 147 305 9.8 0 10 9.5 08/22/2005 12:30:00 1.5 0.9 4.6 0.4 1.7 0.8 4.6 0.4 61 20 56 305 9.8 0 10 9.7 08/22/2005 12:40:00 3.2 0.8 5.3 1.5 3.3 0.8 5.7 1.5 67 14 60 305 9.6 0 10 9.5 08/22/2005 12:50:00 2.9 0.7 4.6 1.1 2.9 0.6 4.2 1.5 60 9 84 305 9.3 0.1 9.7 9.2 08/22/2005 13:00:00 3 0.7 4.6 1.1 3.1 0.7 4.6 1.5 61 13 60 305 9.2 0 9.5 9.2 08/22/2005 13:10:00 2.9 0.8 5.3 0.7 3 0.8 5.7 1.1 61 13 56 305 9.2 0 9.5 9.2 08/22/2005 13:20:00 3.3 0.7 4.9 0.7 3.3 0.7 4.9 1.5 53 16 56 305 9.3 0 9.5 9.2 08/22/2005 13:30:00 3.6 1.1 5.7 0.4 3.6 1 6.1 0.7 68 15 61 305 9.6 0 9.7 9.2 08/22/2005 13:40:00 3.2 0.8 4.9 0.4 3.3 0.7 5.3 1.5 73 26 66 305 9.7 0 10 9.7 08/22/2005 13:50:00 2.7 0.9 5.3 0.4 2.7 0.8 5.3 1.1 78 18 68 305 10 0.1 10.2 9.7 08/22/2005 14:00:00 3.5 0.7 4.9 1.5 3.4 0.7 4.9 1.9 77 10 78 305 10.3 0 10.5 10.2 08/22/2005 14:10:00 4 0.5 5.3 3 3.9 0.5 5.7 2.6 76 9 92 305 10.2 0 10.2 10 08/22/2005 14:20:00 4.3 0.3 4.9 3.8 4.2 0.3 4.9 3.4 70 4 75 305 10 0 10.2 10 08/22/2005 14:30:00 4.5 0.4 5.3 3.8 4.2 0.4 5.3 3 75 5 65 305 10.1 0 10.2 10 08/22/2005 14:40:00 5.1 0.6 6.5 3.4 4.9 0.6 6.1 3 73 6 74 305 10.2 0 10.2 10 08/22/2005 14:50:00 5.7 0.4 6.5 4.2 5.4 0.4 6.5 4.2 76 5 77 305 10.2 0 10.5 10.2 08/22/2005 15:00:00 6.3 0.5 7.2 4.9 6 0.5 6.8 4.6 71 4 69 305 10.4 0 10.5 10.2 08/22/2005 15:10:00 6.4 0.4 7.2 4.9 6.1 0.4 7.2 4.9 70 3 73 305 10.4 0 10.8 10.2 08/22/2005 15:20:00 5.9 0.5 6.8 4.6 5.7 0.5 6.8 4.2 77 5 79 305 10.7 0 10.8 10.5 08/22/2005 15:30:00 5.8 0.7 7.6 4.2 5.5 0.7 7.2 3.4 75 6 72 305 10.8 0 11 10.5 08/22/2005 15:40:00 6.3 0.5 7.6 4.9 6 0.5 7.2 4.2 67 5 63 305 10.7 0 11 10.5 08/22/2005 15:50:00 6.4 0.5 7.6 5.3 6.2 0.5 7.6 4.9 60 6 48 305 10.6 0 10.8 10.2 08/22/2005 16:00:00 6.3 0.4 7.2 5.3 6.1 0.4 7.2 4.6 55 5 57 305 10.5 0 10.8 10.2 08/22/2005 16:10:00 5.7 0.3 6.5 4.9 5.6 0.3 6.5 4.6 48 4 53 305 10.4 0 10.5 10.2 08/22/2005 16:20:00 5.5 0.6 6.5 4.2 5.3 0.6 6.5 3.8 51 5 54 305 10.4 0 10.5 10.2 08/22/2005 16:30:00 5.5 0.4 6.5 4.6 5.4 0.4 6.1 4.2 44 3 40 305 10.3 0 10.5 10.2 08/22/2005 16:40:00 6 0.4 7.2 5.3 6 0.4 6.8 4.9 41 3 41 305 10.2 0 10.2 10 08/22/2005 16:50:00 6.7 0.3 7.2 6.1 6.7 0.3 7.6 6.1 38 3 40 305 10 0 10.2 10 08/22/2005 17:00:00 7.1 0.4 8 5.3 7 0.5 8 4.9 38 4 42 305 10 0 10.2 10 08/22/2005 17:10:00 7 0.4 7.6 5.7 6.9 0.4 7.6 5.3 32 4 29 305 10.2 0 10.2 10 08/22/2005 17:20:00 7.1 0.3 8 6.1 6.9 0.4 8 5.3 45 4 48 305 10.2 0 10.5 10.2 08/22/2005 17:30:00 7.8 0.6 8.8 6.1 7.4 0.7 8.8 5.7 50 3 52 305 10.3 0 10.5 10.2 08/22/2005 17:40:00 8 0.5 9.1 6.5 7.7 0.5 8.8 6.1 47 3 45 305 10.2 0 10.2 10.2 08/22/2005 17:50:00 7.9 0.6 9.1 6.5 7.7 0.7 9.1 5.7 41 3 44 305 10.2 0 10.2 10.2 08/22/2005 18:00:00 8.5 0.4 9.1 6.8 8.4 0.5 9.5 6.5 40 3 44 305 9.9 0 10.2 9.7 08/22/2005 18:10:00 8.1 0.4 8.8 7.2 8 0.5 8.8 6.5 33 3 34 305 9.8 0 10 9.7 08/22/2005 18:20:00 8 0.5 9.1 6.5 7.8 0.6 9.1 5.3 31 3 30 305 9.8 0 10 9.7 08/22/2005 18:30:00 7.9 0.4 8.8 6.8 7.8 0.5 9.1 5.7 28 4 27 305 9.7 0 10 9.7 08/22/2005 18:40:00 8.3 0.5 9.1 6.8 8 0.5 8.8 6.5 31 3 32 305 9.7 0 10 9.7 08/22/2005 18:50:00 8.5 0.5 9.5 7.2 8.4 0.5 9.5 6.8 32 3 36 305 9.8 0 10 9.7 08/22/2005 19:00:00 8.5 0.5 9.5 7.2 8.3 0.6 9.5 6.5 34 4 40 305 9.8 0 10 9.7 08/22/2005 19:10:00 8.8 0.6 9.9 6.8 8.4 0.6 9.5 6.1 32 3 33 305 9.9 0 10 9.7 08/22/2005 19:20:00 9.3 0.6 10.7 8 8.9 0.6 10.3 7.2 32 4 30 305 9.8 0 10 9.7 08/22/2005 19:30:00 8.7 0.5 9.9 7.2 8.4 0.6 9.9 6.8 35 3 32 305 9.7 0 10 9.7 08/22/2005 19:40:00 9.2 0.5 9.9 7.6 9.1 0.5 9.9 6.8 33 2 32 305 9.6 0 9.7 9.5 08/22/2005 19:50:00 8.8 0.6 9.9 7.2 8.6 0.6 9.9 7.2 32 3 27 305 9.5 0 9.7 9.2 08/22/2005 20:00:00 8.8 0.6 10.3 6.8 8.6 0.7 10.7 6.8 30 4 30 305 9.5 0 9.7 9.5 08/22/2005 20:10:00 9.4 0.5 10.3 8 9.2 0.5 10.3 7.6 31 3 31 305 9.5 0 9.7 9.5 08/22/2005 20:20:00 9.4 0.4 10.3 8 9.2 0.5 10.3 8 28 3 28 305 9.5 0 9.7 9.5 08/22/2005 20:30:00 8.8 0.5 10.3 7.2 8.6 0.5 9.9 7.2 28 4 29 305 9.3 0 9.5 9.2 08/22/2005 20:40:00 9 0.6 9.9 7.2 9 0.7 9.9 6.8 25 3 22 305 9.2 0 9.5 9.2 08/22/2005 20:50:00 9 0.5 10.3 7.2 8.8 0.5 10.3 6.8 26 3 26 305 9.2 0 9.5 9.2 08/22/2005 21:00:00 9.1 0.8 10.3 7.2 9.1 0.8 10.3 6.8 27 3 24 305 9.2 0 9.2 9.2 08/22/2005 21:10:00 8.7 0.7 9.9 7.2 8.5 0.7 9.9 6.8 28 3 19 305 9.1 0 9.2 8.9 08/22/2005 21:20:00 8.6 0.5 9.9 7.2 8.5 0.6 10.3 6.8 29 4 31 305 9 0 9.2 8.9 08/22/2005 21:30:00 8.9 0.5 10.3 7.6 8.7 0.5 9.9 7.2 30 3 31 305 8.9 0 9.2 8.9 08/22/2005 21:40:00 8.8 0.6 10.3 7.2 8.7 0.6 9.9 7.2 25 4 24 305 8.7 0 8.9 8.4 08/22/2005 21:50:00 8.9 0.5 9.9 7.6 8.8 0.5 9.9 7.2 24 3 30 305 8.6 0 8.7 8.4 08/22/2005 22:00:00 8.1 0.5 9.5 6.5 8 0.5 9.5 6.5 20 3 20 305 8.4 0 8.7 8.2 08/22/2005 22:10:00 8.8 0.6 10.3 7.2 8.7 0.6 9.9 7.2 23 3 20 305 8.3 0 8.4 8.2 08/22/2005 22:20:00 9 0.6 10.3 7.2 8.9 0.6 10.3 6.8 28 3 27 305 8.4 0 8.4 8.2 08/22/2005 22:30:00 9.9 0.5 11.1 8.4 9.7 0.5 11.1 8 31 3 29 305 8.3 0 8.4 8.2 08/22/2005 22:40:00 9.3 0.6 10.7 8 9.1 0.7 10.7 7.2 32 3 36 305 8.2 0 8.4 8.2 08/22/2005 22:50:00 8.8 0.5 9.9 7.2 8.7 0.5 9.9 7.2 26 4 30 305 8.2 0 8.2 8.2 08/22/2005 23:00:00 8.9 0.6 10.3 7.2 8.8 0.6 10.7 7.2 25 3 27 305 8.2 0 8.4 8.2 08/22/2005 23:10:00 9 0.6 9.9 7.2 8.9 0.6 10.3 7.2 20 3 17 305 8.4 0 8.4 8.2 08/22/2005 23:20:00 8.7 0.7 10.3 6.5 8.7 0.7 10.3 6.8 13 3 17 305 8.5 0 8.7 8.4 08/22/2005 23:30:00 8.5 0.7 10.3 6.8 8.5 0.7 9.9 6.1 6 6 14 305 8.5 0 8.7 8.2 08/22/2005 23:40:00 8.9 0.5 9.9 7.6 9 0.5 10.3 7.2 0 3 0 305 8.2 0 8.4 8.2 08/22/2005 23:50:00 9.1 0.6 10.3 7.6 9.2 0.6 10.7 7.6 4 3 2 305 8 0 8.2 7.7 08/23/2005 00:00:00 9 0.6 10.3 7.2 9.2 0.6 10.7 7.2 0 5 5 305 7.9 0 8.4 7.7 08/23/2005 00:10:00 9.6 0.5 10.7 8 9.8 0.6 10.7 8.4 2 3 8 305 7.6 0 7.9 7.4 08/23/2005 00:20:00 9.4 0.5 10.7 7.6 9.5 0.6 10.7 7.6 8 3 2 305 7.3 0 7.7 7.2 08/23/2005 00:30:00 9.1 0.6 10.7 7.6 9.3 0.6 10.7 7.6 10 3 15 305 7.3 0 7.9 7.2 08/23/2005 00:40:00 8.9 0.6 10.3 6.5 9 0.6 10.3 6.8 10 4 5 305 7.5 0 7.9 7.2 08/23/2005 00:50:00 9.2 0.6 10.3 8 9.3 0.6 10.7 7.6 14 3 15 305 7.7 0.1 8.2 7.4 08/23/2005 01:00:00 9.5 0.5 11.1 7.6 9.6 0.6 11.1 7.6 8 3 14 305 7.7 0.1 8.2 7.7 08/23/2005 01:10:00 9.5 0.7 11.1 7.6 9.5 0.8 11.5 7.6 10 3 11 305 7.9 0 8.2 7.7 08/23/2005 01:20:00 10.1 0.8 11.8 8.4 10.2 0.8 12.2 7.6 11 4 10 305 7.9 0 7.9 7.7 08/23/2005 01:30:00 9.8 0.8 11.8 7.2 9.9 0.9 12.2 7.2 11 4 11 305 7.9 0 8.2 7.7 08/23/2005 01:40:00 9.2 0.6 10.7 7.6 9.4 0.7 11.1 7.2 359 8 10 305 7.9 0.1 8.4 7.7 08/23/2005 01:50:00 9 0.7 10.7 7.2 9.2 0.7 10.7 7.2 359 5 2 305 7.4 0 7.7 7.4 08/23/2005 02:00:00 9.2 0.6 11.1 7.6 9.4 0.6 11.5 7.6 2 3 0 305 7.5 0 8.2 7.4 08/23/2005 02:10:00 9.8 0.7 11.5 7.6 10 0.7 11.5 7.6 4 3 8 305 7.7 0 7.9 7.7 08/23/2005 02:20:00 10.1 0.8 12.2 8 10.1 0.8 12.6 8 4 4 8 305 7.9 0 8.2 7.7 08/23/2005 02:30:00 10.9 1 13 8.8 11 1.1 13.7 8.8 3 4 5 305 8.1 0 8.2 7.9 08/23/2005 02:40:00 11.2 0.9 13.3 8.8 11.3 1 14.1 8.8 2 3 1 305 8.2 0 8.4 8.2 08/23/2005 02:50:00 11.2 0.9 13 8.8 11.3 1 13.3 8.8 359 4 1 305 8.3 0 8.4 8.2 08/23/2005 03:00:00 11.7 0.8 13.3 8.8 11.8 1 13.7 8.4 358 3 355 305 8.4 0 8.4 8.2 08/23/2005 03:10:00 12 1 13.7 8.8 12 1.1 13.7 8.8 1 3 358 305 8.4 0 8.4 8.2 08/23/2005 03:20:00 11.6 0.7 13.3 9.9 11.7 0.8 13.7 9.5 3 3 357 305 8.4 0 8.4 8.4 08/23/2005 03:30:00 11.5 1 14.1 9.1 11.6 1 14.1 9.1 4 3 6 305 8.5 0 8.7 8.4 08/23/2005 03:40:00 11.1 0.8 13 9.5 11.2 0.8 13.7 9.1 2 3 4 305 8.5 0 8.7 8.4 08/23/2005 03:50:00 10.9 0.8 12.6 9.1 11 0.8 13 9.1 0 3 358 305 8.6 0 8.7 8.4 08/23/2005 04:00:00 11.2 0.9 13.7 9.1 11.4 0.9 13.7 9.1 0 3 0 305 8.6 0 8.7 8.4 08/23/2005 04:10:00 11.3 0.8 13.3 9.1 11.4 0.9 13.7 9.1 0 4 3 305 8.6 0 8.7 8.4 08/23/2005 04:20:00 11.4 1 14.1 8 11.5 1.1 14.1 8.4 356 5 359 305 8.6 0 8.7 8.2 08/23/2005 04:30:00 11.3 0.7 13 9.1 11.5 0.8 13.7 9.1 352 3 351 305 8.2 0 8.4 8.2 08/23/2005 04:40:00 12.1 1 14.1 9.5 12.2 1.1 14.9 9.1 357 4 352 305 8.2 0 8.4 8.2 08/23/2005 04:50:00 12.1 0.9 14.5 9.9 12.2 1 14.9 9.5 2 3 4 305 8.3 0 8.4 8.2 08/23/2005 05:00:00 11.8 1 14.1 9.5 11.8 1 14.5 9.1 2 4 6 305 8.4 0 8.4 8.2 08/23/2005 05:10:00 12.8 0.9 14.9 10.3 12.9 0.9 14.9 10.3 1 3 4 305 8.3 0 8.4 8.2 08/23/2005 05:20:00 12.8 0.7 14.5 10.7 12.9 0.8 15.3 10.7 1 3 3 305 8.3 0 8.4 8.2 08/23/2005 05:30:00 13 1 14.9 9.9 13.1 1.1 15.3 9.1 357 4 357 305 8.3 0 8.4 8.2 08/23/2005 05:40:00 13.4 0.9 15.3 10.3 13.4 1 16.1 10.7 358 3 358 305 8.2 0 8.2 8.2 08/23/2005 05:50:00 13.8 1.1 16.4 11.1 13.8 1.2 16.8 10.3 359 3 359 305 8.2 0 8.4 8.2 08/23/2005 06:00:00 13.2 1.1 14.9 10.3 13.4 1.2 15.6 10.3 1 3 2 305 8.3 0 8.4 8.2 08/23/2005 06:10:00 13.1 1 14.9 10.7 13.2 1 15.6 10.3 357 4 356 305 8.2 0 8.7 8.2 08/23/2005 06:20:00 12.6 0.9 14.9 9.9 12.7 1 15.3 9.9 358 3 359 305 8.3 0 8.4 8.2 08/23/2005 06:30:00 12.9 0.8 14.9 10.3 13.1 0.8 15.3 10.7 358 3 358 305 8.4 0 8.4 8.2 08/23/2005 06:40:00 12.4 1 14.9 9.9 12.6 1.1 15.6 10.3 354 4 350 305 8.4 0 8.4 8.2 08/23/2005 06:50:00 13.1 1 14.9 9.9 13.2 1 15.3 10.7 357 4 355 305 8.2 0 8.4 8.2 08/23/2005 07:00:00 12.9 1 15.3 9.9 13 1 15.6 9.9 357 4 0 305 8.1 0 8.2 8.2 08/23/2005 07:10:00 13.5 1 15.6 11.1 13.5 1 16.4 11.1 4 4 7 305 8.2 0 8.4 8.2 08/23/2005 07:20:00 14.2 0.9 16.4 11.8 14.2 1 16.8 11.8 5 3 6 305 8.2 0 8.2 8.2 08/23/2005 07:30:00 13.4 1.2 16.1 11.1 13.3 1.2 16.4 10.7 3 4 6 305 8.2 0 8.2 8.2 08/23/2005 07:40:00 14 1 16.1 11.1 14.1 1 16.4 10.7 1 4 2 305 8.1 0 8.2 8.2 08/23/2005 07:50:00 13.4 1.2 16.1 9.5 13.6 1.2 16.4 10.3 356 4 355 305 8.1 0 8.2 7.9 08/23/2005 08:00:00 12.9 1.1 15.3 10.3 13 1.2 15.6 9.1 354 3 355 305 8.1 0 8.2 7.9 08/23/2005 08:10:00 13.6 1.2 16.1 10.7 13.8 1.2 16.1 9.9 355 3 356 305 8.1 0 8.2 8.2 08/23/2005 08:20:00 13.2 1.3 16.8 9.9 13.3 1.5 17.2 9.9 353 4 353 305 8.1 0 8.2 8.2 08/23/2005 08:30:00 13.7 1.3 17.2 10.3 13.8 1.3 17.2 10.3 354 4 357 305 8.2 0 8.2 8.2 08/23/2005 08:40:00 13.6 1.2 17.2 11.1 13.8 1.2 17.2 10.7 353 4 354 305 8.1 0 8.2 7.9 08/23/2005 08:50:00 13.6 1 16.1 10.7 13.9 1 16.1 10.7 352 4 355 305 8 0 8.2 7.9 08/23/2005 09:00:00 13.7 1 16.4 10.7 13.9 1 16.8 10.7 352 3 356 305 7.9 0 8.2 7.7 08/23/2005 09:10:00 13.4 1 16.1 11.5 13.5 1.1 16.1 10.7 352 4 348 305 7.8 0 8.2 7.7 08/23/2005 09:20:00 13.3 1.2 16.1 10.3 13.4 1.2 16.4 9.1 351 4 1 305 7.7 0 7.9 7.7 08/23/2005 09:30:00 13.6 1.1 16.4 10.7 13.7 1.2 16.4 10.3 351 4 351 305 7.8 0 7.9 7.7 08/23/2005 09:40:00 13 1.1 15.6 9.9 13.2 1.2 16.1 9.9 353 4 350 305 7.9 0 8.2 7.7 08/23/2005 09:50:00 13.2 1 15.6 10.3 13.3 1.1 16.1 10.7 351 4 347 305 7.9 0 8.2 7.7 08/23/2005 10:00:00 13.8 1.1 16.8 10.3 13.9 1.2 17.2 9.9 352 4 357 305 7.9 0 8.2 7.7 08/23/2005 10:10:00 13.8 0.9 15.6 10.7 13.9 1.1 16.4 9.9 352 4 352 305 7.9 0 8.2 7.9 08/23/2005 10:20:00 14 1 16.4 11.5 14.2 1.1 16.8 11.1 351 4 351 305 7.9 0 8.2 7.7 08/23/2005 10:30:00 13.6 1.2 15.6 9.9 13.7 1.2 16.1 9.9 352 4 354 305 7.8 0 8.2 7.7 08/23/2005 10:40:00 13.9 1.3 16.4 10.3 14 1.3 17.2 10.7 352 4 356 305 7.7 0 7.9 7.7 08/23/2005 10:50:00 13.8 1.1 16.1 10.3 14 1.1 16.4 10.3 351 3 351 305 7.8 0 7.9 7.7 08/23/2005 11:00:00 13.2 1.2 16.8 10.7 13.4 1.2 16.8 10.3 349 4 349 305 7.7 0 7.9 7.7 08/23/2005 11:10:00 13.4 1.1 15.6 9.9 13.6 1.2 16.1 9.1 348 3 347 305 7.7 0 7.9 7.7 08/23/2005 11:20:00 12.9 1.2 15.6 9.9 13 1.3 16.1 9.9 349 5 350 305 7.7 0 7.9 7.7 08/23/2005 11:30:00 13.5 1.1 15.6 10.7 13.6 1.2 16.1 9.9 347 4 350 305 7.9 0 7.9 7.9 08/23/2005 11:40:00 13.6 1 16.1 10.7 13.7 1 16.8 10.7 346 4 350 305 7.9 0 8.2 7.9 08/23/2005 11:50:00 12.9 1.3 15.3 8.8 13 1.3 15.6 8.4 344 4 341 305 8 0 8.2 7.9 08/23/2005 12:00:00 13.2 1.1 15.6 10.7 13.4 1.2 16.4 9.9 346 4 352 305 8 0 8.2 7.9 08/23/2005 12:10:00 12.7 1 15.6 9.5 12.9 1.1 15.6 9.9 345 4 344 305 8 0 8.2 7.9 08/23/2005 12:20:00 12.2 1 14.5 9.5 12.4 1.1 14.9 9.5 345 4 347 305 8.1 0 8.2 7.9 08/23/2005 12:30:00 13 1.3 15.6 9.9 13 1.5 15.6 9.1 344 4 346 305 8.1 0 8.2 7.9 08/23/2005 12:40:00 13.1 1.2 14.9 9.5 13.3 1.3 15.6 9.9 344 3 340 305 8.2 0 8.4 8.2 08/23/2005 12:50:00 12.2 1.1 14.9 9.5 12.3 1.2 15.3 9.5 344 4 345 305 8.3 0 8.4 8.2 08/23/2005 13:00:00 12.1 1.1 14.9 9.5 12.2 1.1 15.3 9.1 342 4 348 305 8.6 0 8.7 8.4 08/23/2005 13:10:00 12.1 0.9 14.1 9.5 12.2 1.1 14.5 9.5 343 4 340 305 8.6 0 8.9 8.4 08/23/2005 13:20:00 11.9 0.8 13.7 9.5 11.8 1 14.1 8.8 344 4 342 305 9.1 0 9.2 8.9 08/23/2005 13:30:00 12.2 0.8 14.1 9.5 12.4 0.9 14.5 9.9 344 4 351 305 9.1 0 9.2 8.9 08/23/2005 13:40:00 12.1 1.1 14.1 8.4 12.1 1.2 14.1 8.4 343 4 340 305 9.1 0 9.5 8.9 08/23/2005 13:50:00 12.1 1.1 14.5 8.4 12.2 1.2 15.3 8.8 343 4 344 305 9.1 0 9.5 8.9 08/23/2005 14:00:00 12 0.8 14.1 9.5 12.1 0.9 14.9 9.1 340 4 340 305 8.9 0.1 9.2 8.9 08/23/2005 14:10:00 11.3 0.9 13 8.8 11.4 1 13.7 7.2 345 4 340 305 9.1 0.1 9.5 8.9 08/23/2005 14:20:00 10.4 0.9 12.2 6.8 10.5 1 12.6 7.2 346 4 347 305 9.2 0 9.5 9.2 08/23/2005 14:30:00 10.1 0.8 11.8 8 10.2 1 12.2 7.2 345 4 339 305 9.5 0.1 9.7 9.2 08/23/2005 14:40:00 10.4 0.9 12.6 7.6 10.5 1 12.2 7.6 343 4 333 305 9.7 0 10 9.5 08/23/2005 14:50:00 10.3 1 12.6 7.2 10.3 1.1 13 7.2 341 5 337 305 9.8 0 10 9.7 08/23/2005 15:00:00 9.8 1 12.6 7.2 9.9 1.1 12.6 7.2 342 4 340 305 9.8 0 10 9.7 08/23/2005 15:10:00 10.1 1 12.2 7.6 10.1 1.1 12.6 7.6 341 4 344 305 9.9 0 10.2 9.7 08/23/2005 15:20:00 10.3 0.8 12.2 8 10.4 1 12.2 7.6 343 3 348 305 9.9 0 10.2 9.7 08/23/2005 15:30:00 10.4 0.7 12.2 8 10.5 0.8 13 8.4 343 4 340 305 9.9 0 10.2 9.7 08/23/2005 15:40:00 10 0.9 12.2 8 10 1 12.2 8 344 5 344 305 9.9 0 10.2 9.7 08/23/2005 15:50:00 10.2 0.9 12.2 7.6 10.3 1 12.2 7.6 349 4 354 305 9.7 0 10 9.5 08/23/2005 16:00:00 10.8 0.9 12.6 8.8 11.1 0.9 13 8.8 349 4 346 305 9.7 0 10 9.7 08/23/2005 16:10:00 10.6 0.9 13 8 10.6 1 13 7.6 348 4 351 305 10 0 10.2 9.7 08/23/2005 16:20:00 10.7 0.9 12.2 8 10.7 1 13 7.2 349 4 347 305 10.2 0 10.8 10 08/23/2005 16:30:00 11.3 0.8 13 9.1 11.4 0.9 13.3 8.4 349 3 347 305 10 0.1 10.2 9.7 08/23/2005 16:40:00 10.8 0.7 12.2 8.8 10.9 0.8 12.6 8 350 4 347 305 9.9 0 10 9.7 08/23/2005 16:50:00 10.1 1 12.2 7.2 10.2 1 12.2 7.6 350 4 354 305 9.7 0 10 9.5 08/23/2005 17:00:00 9.7 0.9 11.8 7.2 9.8 1 11.8 7.2 350 4 343 305 9.9 0 10.2 9.7 08/23/2005 17:10:00 9.9 1 11.8 7.2 10 1.1 11.8 6.1 351 3 348 305 9.9 0 10.2 9.7 08/23/2005 17:20:00 9.6 0.8 11.1 7.2 9.7 0.8 11.1 6.5 355 3 357 305 9.8 0 10 9.7 08/23/2005 17:30:00 8.6 0.7 10.3 6.1 8.5 0.8 10.3 5.7 354 4 352 305 10.1 0 10.2 10 08/23/2005 17:40:00 8 0.6 9.1 6.5 8.1 0.7 9.5 6.1 354 3 355 305 9.8 0 10 9.5 08/23/2005 17:50:00 7.9 0.8 9.5 5.7 7.9 0.9 9.9 5.7 349 3 349 305 9.9 0 10 9.7 08/23/2005 18:00:00 7.7 0.7 9.1 5.7 7.8 0.8 9.5 5.7 349 4 348 305 9.8 0 10 9.7 08/23/2005 18:10:00 8.9 1.1 10.7 6.1 9 1.2 11.1 5.7 353 4 351 305 9.7 0 9.7 9.5 08/23/2005 18:20:00 9.6 0.7 11.1 8 9.7 0.8 11.5 7.6 354 3 359 305 9.5 0.1 9.7 9.2 08/23/2005 18:30:00 9.1 0.6 10.3 7.2 9.3 0.8 10.7 6.8 353 3 353 305 9.4 0 9.7 9.2 08/23/2005 18:40:00 8.8 0.7 10.7 6.8 8.8 0.7 10.7 6.8 354 3 351 305 9.7 0 10 9.5 08/23/2005 18:50:00 8.7 0.5 9.9 7.6 8.7 0.6 9.9 6.8 0 5 0 305 9.4 0.1 9.7 9.2 08/23/2005 19:00:00 7.6 0.7 9.1 5.7 7.6 0.7 9.1 5.7 2 4 356 305 9.1 0 9.2 8.7 08/23/2005 19:10:00 6.8 0.8 9.1 4.9 6.9 0.8 9.5 4.9 2 6 5 305 9.1 0 9.5 8.9 08/23/2005 19:20:00 6.7 0.6 8 5.3 6.8 0.7 8.4 4.9 359 3 0 305 9.5 0 9.7 9.2 08/23/2005 19:30:00 6.1 0.7 7.6 4.2 6.2 0.8 8 4.2 357 4 354 305 9.7 0 10 9.5 08/23/2005 19:40:00 6.3 0.6 7.6 4.6 6.3 0.7 8 4.2 357 5 5 305 9.7 0 10 9.5 08/23/2005 19:50:00 7.2 0.7 8.8 4.6 7.3 0.8 8.8 4.9 4 3 4 305 9.5 0 9.7 9.5 08/23/2005 20:00:00 6.4 0.6 7.6 4.9 6.5 0.6 8 4.9 6 3 7 305 9.4 0 9.7 9.2 08/23/2005 20:10:00 4.9 0.7 6.1 3.4 5 0.7 6.5 3.4 9 3 8 305 9.4 0 9.7 9.2 08/23/2005 20:20:00 5.3 0.7 6.5 2.6 5.4 0.6 6.5 3.4 6 4 9 305 9.6 0 9.7 9.5 08/23/2005 20:30:00 6 0.6 7.2 4.6 6.1 0.7 7.6 4.2 357 3 355 305 9.6 0 9.7 9.5 08/23/2005 20:40:00 5.8 0.4 7.2 4.6 5.9 0.5 7.2 4.6 0 3 0 305 9.5 0 9.7 9.5 08/23/2005 20:50:00 5.8 0.5 6.8 4.6 5.9 0.5 6.8 4.6 357 3 359 305 9.4 0 9.5 9.2 08/23/2005 21:00:00 5.4 0.7 6.8 3.8 5.6 0.7 6.8 3.8 355 3 358 305 9.3 0 9.5 9.2 08/23/2005 21:10:00 5.4 0.4 6.1 4.6 5.7 0.4 6.5 4.6 351 3 353 305 9.1 0 9.2 8.9 08/23/2005 21:20:00 4.5 0.4 5.3 3.4 4.7 0.4 5.7 3.8 344 5 354 305 8.9 0.1 9.2 8.7 08/23/2005 21:30:00 3.9 0.6 5.3 3 4.1 0.6 5.3 2.6 341 6 344 305 8.8 0 8.9 8.7 08/23/2005 21:40:00 3.1 0.4 4.2 1.9 3.3 0.4 4.2 1.9 334 5 344 305 8.6 0 8.9 8.4 08/23/2005 21:50:00 2.7 0.3 3.4 1.9 2.9 0.3 3.4 2.3 330 3 327 305 8.6 0 8.7 8.4 08/23/2005 22:00:00 2.9 0.3 3.4 2.3 3.1 0.3 3.8 2.3 325 4 324 305 8.5 0 8.7 8.4 08/23/2005 22:10:00 1.9 0.3 2.6 1.5 2.1 0.3 3 1.5 310 5 317 305 8.3 0 8.4 8.2 08/23/2005 22:20:00 1.6 0.2 2.3 1.1 1.8 0.3 2.3 1.1 314 4 313 305 8.1 0 8.2 8.2 08/23/2005 22:30:00 2 0.4 3.4 1.1 2.2 0.4 3.4 1.5 350 9 352 305 8.1 0 8.2 8.2 08/23/2005 22:40:00 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 0 4 0 305 8.2 0 8.2 8.2 08/23/2005 22:50:00 3.7 1 5.7 2.3 3.7 0.9 5.7 2.3 14 6 16 305 8.2 0 8.4 8.2 08/23/2005 23:00:00 5.1 0.2 5.7 4.6 5.3 0.2 5.7 4.9 23 3 18 305 8.1 0 8.2 7.9 08/23/2005 23:10:00 4.6 0.2 5.3 4.2 4.7 0.3 5.3 4.2 27 2 26 305 8 0 8.2 7.9 08/23/2005 23:20:00 5 0.4 5.7 3.8 5 0.4 6.1 4.2 24 4 27 305 7.9 0 8.2 7.7 08/23/2005 23:30:00 5.2 0.3 5.7 4.2 5.2 0.3 5.7 4.6 20 3 16 305 7.7 0 7.9 7.7 08/23/2005 23:40:00 4.8 0.3 5.3 3.8 4.7 0.3 5.3 3.8 21 3 20 305 7.7 0 7.9 7.7 08/23/2005 23:50:00 4.3 0.5 5.3 3 4.3 0.5 5.3 3.4 26 4 25 305 7.5 0 7.7 7.4 08/24/2005 00:00:00 3.6 0.3 4.6 2.6 3.6 0.3 4.2 3 25 5 23 305 7.5 0 7.9 7.4 08/24/2005 00:10:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 26 4 27 305 7.5 0 7.7 7.4 08/24/2005 00:20:00 3.9 0.2 4.6 3.4 3.9 0.3 4.6 3 31 3 30 305 7.5 0 7.7 7.4 08/24/2005 00:30:00 3.6 0.3 4.6 3 3.7 0.3 4.2 3 28 3 26 305 7.4 0 7.7 7.4 08/24/2005 00:40:00 3.5 0.3 4.2 2.6 3.6 0.3 4.2 2.6 41 7 31 305 7.3 0 7.7 7.2 08/24/2005 00:50:00 3.4 0.3 4.2 2.6 3.6 0.2 4.2 3 48 6 47 305 7.3 0 7.4 7.2 08/24/2005 01:00:00 3.1 0.4 4.2 2.3 3.3 0.3 4.2 2.6 44 6 33 305 7.4 0 7.7 7.4 08/24/2005 01:10:00 5 0.6 6.1 2.6 5 0.6 6.1 3 31 5 29 305 7.3 0 7.4 7.4 08/24/2005 01:20:00 4.8 0.4 5.3 3.8 4.9 0.4 5.7 4.2 26 3 26 305 7.3 0 7.4 7.4 08/24/2005 01:30:00 4.9 0.4 5.7 4.2 5.1 0.4 6.1 4.2 28 4 23 305 7.3 0 7.4 7.4 08/24/2005 01:40:00 5.3 0.3 6.1 4.6 5.4 0.3 6.1 4.6 30 3 33 305 7.3 0 7.4 7.4 08/24/2005 01:50:00 5.5 0.2 6.1 4.9 5.6 0.2 6.1 4.9 29 4 31 305 7.2 0 7.4 7.2 08/24/2005 02:00:00 4.7 0.5 5.7 3.4 4.9 0.5 6.1 3.8 28 4 25 305 7.2 0 7.4 7.2 08/24/2005 02:10:00 4.5 0.4 5.3 3.8 4.6 0.4 5.7 3.8 29 4 33 305 7.2 0 7.4 7.2 08/24/2005 02:20:00 4.8 0.4 5.7 3.8 4.9 0.4 5.7 3.8 27 3 29 305 7.2 0 7.2 7.2 08/24/2005 02:30:00 4.9 0.4 5.7 3.8 5.1 0.4 5.7 3.8 26 5 27 305 7.2 0 7.2 7.2 08/24/2005 02:40:00 4.8 0.4 5.7 3.8 5 0.4 6.5 4.2 24 4 27 305 7.1 0 7.2 7.2 08/24/2005 02:50:00 4.8 0.5 6.1 3.8 4.9 0.5 6.1 3.8 27 4 31 305 7 0 7.2 7.2 08/24/2005 03:00:00 5 0.3 5.7 4.2 5.1 0.3 5.7 3.8 21 4 27 305 7 0 7.2 7.2 08/24/2005 03:10:00 5 0.4 5.7 4.2 5.1 0.4 5.7 3.8 19 4 17 305 7 0 7.4 7.2 08/24/2005 03:20:00 5.2 0.4 6.1 4.2 5.4 0.4 6.1 4.2 21 3 23 305 7 0 7.2 6.9 08/24/2005 03:30:00 5 0.3 6.1 3.8 5.1 0.3 6.1 4.2 23 5 29 305 7 0 7.2 6.9 08/24/2005 03:40:00 4.8 0.5 5.7 3.4 4.8 0.4 6.1 3.8 23 4 22 305 6.9 0 7.2 6.9 08/24/2005 03:50:00 4.7 0.5 5.7 3.8 4.9 0.4 5.7 3.8 16 3 18 305 6.9 0 7.2 6.9 08/24/2005 04:00:00 4.4 0.4 5.3 3.4 4.6 0.3 5.3 3.8 21 4 28 305 6.9 0 7.4 6.9 08/24/2005 04:10:00 4.8 0.4 5.7 4.2 4.9 0.4 6.1 3.8 17 5 23 305 7 0 7.2 6.9 08/24/2005 04:20:00 4.5 0.4 5.7 3.8 4.6 0.5 5.7 3.8 16 3 15 305 6.9 0 7.2 6.9 08/24/2005 04:30:00 4.4 0.4 5.7 3.4 4.6 0.5 5.7 3.4 16 3 24 305 6.9 0 7.4 6.9 08/24/2005 04:40:00 3.8 0.5 4.9 2.6 4.1 0.5 5.3 3 20 3 19 305 6.9 0 7.4 6.9 08/24/2005 04:50:00 3.8 0.3 4.6 3 4 0.3 4.9 3.4 16 3 13 305 6.8 0 7.2 6.9 08/24/2005 05:00:00 3.4 0.3 4.2 2.6 3.7 0.3 4.6 3 10 4 19 305 6.9 0 7.4 6.9 08/24/2005 05:10:00 2.9 0.4 3.8 1.9 3.1 0.4 3.8 2.3 14 4 11 305 6.8 0 7.2 6.9 08/24/2005 05:20:00 2.2 0.3 3 1.1 2.5 0.3 3 1.5 9 8 13 305 6.8 0 7.2 6.9 08/24/2005 05:30:00 1.7 0.3 2.6 1.1 2 0.3 3 1.1 9 5 16 305 6.7 0 6.9 6.7 08/24/2005 05:40:00 0.8 0.4 1.5 0.4 1.4 0.3 2.3 0.7 41 14 25 305 6.6 0 6.9 6.4 08/24/2005 05:50:00 0.6 0.3 1.5 0.4 1.2 0.2 1.9 0.4 40 6 28 305 6.5 0 6.7 6.4 08/24/2005 06:00:00 0.8 0.3 1.5 0.4 1.6 0.3 2.3 0.7 23 7 31 305 6.5 0 6.9 6.4 08/24/2005 06:10:00 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 33 3 305 305 6 0.1 6.4 5.6 08/24/2005 06:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 35 1 305 305 5.5 0 5.6 5.4 08/24/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 5.4 0 5.9 5.4 08/24/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 305 305 5.4 0 5.6 5.4 08/24/2005 06:50:00 0.4 0 0.4 0.4 0.4 0.2 0.7 0.4 36 1 305 305 5.6 0 5.9 5.4 08/24/2005 07:00:00 0.4 0.2 1.5 0.4 1.2 0.3 1.9 0.7 117 86 208 305 5.8 0 5.9 5.6 08/24/2005 07:10:00 1.5 0.3 1.9 0.7 2 0.2 2.3 1.5 189 4 208 305 5.4 0 5.6 5.2 08/24/2005 07:20:00 2.2 0.4 3 1.5 2.5 0.4 3.4 1.9 194 3 192 305 5.4 0.1 5.6 5.2 08/24/2005 07:30:00 2.8 0.2 3.4 2.3 3.2 0.2 3.4 2.6 197 4 197 305 6 0.1 6.1 5.6 08/24/2005 07:40:00 3.1 0.2 3.8 2.3 3.3 0.2 3.8 2.6 201 4 197 305 6.4 0 6.4 6.1 08/24/2005 07:50:00 3.3 0.3 4.2 2.6 3.6 0.3 4.2 2.6 203 5 211 305 6.5 0 6.7 6.1 08/24/2005 08:00:00 3.5 0.3 4.2 2.6 3.7 0.4 4.6 2.6 200 5 199 305 6.6 0 6.9 6.4 08/24/2005 08:10:00 3.9 0.3 4.6 3 4.1 0.3 4.6 3 197 4 198 305 6.6 0 7.2 6.4 08/24/2005 08:20:00 4 0.4 4.9 2.6 4.1 0.4 4.9 2.6 194 4 197 305 6.8 0.1 7.2 6.7 08/24/2005 08:30:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 195 3 195 305 6.9 0 7.4 6.7 08/24/2005 08:40:00 4.7 0.4 5.3 3.4 4.8 0.4 5.7 3.4 196 3 197 305 7 0 7.4 6.9 08/24/2005 08:50:00 4.6 0.4 5.7 3 4.6 0.5 5.3 2.6 199 3 196 305 7 0 7.4 7.2 08/24/2005 09:00:00 4.3 0.3 5.3 3.4 4.3 0.4 5.3 3.4 200 4 198 305 7 0 7.4 6.9 08/24/2005 09:10:00 4.1 0.4 4.9 2.6 4.2 0.4 4.9 3 199 8 204 305 7 0 7.4 6.9 08/24/2005 09:20:00 4.2 0.4 5.3 2.6 4.4 0.4 5.3 3 196 6 192 305 7.1 0.1 7.7 7.2 08/24/2005 09:30:00 3.5 0.6 4.6 1.9 3.6 0.6 4.9 2.3 196 7 204 305 7.2 0.1 7.7 7.2 08/24/2005 09:40:00 3.3 0.4 4.2 2.3 3.6 0.4 4.9 2.3 194 7 189 305 7.3 0 7.7 7.2 08/24/2005 09:50:00 3.4 0.4 4.6 1.9 3.6 0.4 4.6 2.6 209 14 203 305 7.8 0.2 8.4 7.4 08/24/2005 10:00:00 3.6 0.3 4.2 2.6 3.7 0.3 4.6 2.6 220 5 214 305 8.6 0 8.7 8.2 08/24/2005 10:10:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 1.9 221 10 227 305 8.8 0.1 8.9 8.4 08/24/2005 10:20:00 3.5 0.6 4.9 1.9 3.6 0.6 5.3 2.3 221 10 213 305 8.8 0 8.9 8.7 08/24/2005 10:30:00 3.3 1 5.3 0.7 3.2 1.1 5.3 1.1 268 30 294 305 9.1 0.1 9.5 8.9 08/24/2005 10:40:00 4.2 0.6 5.7 3 4.3 0.5 5.7 3 296 10 309 305 9.6 0.1 9.7 9.2 08/24/2005 10:50:00 5 0.5 6.1 3.4 4.9 0.4 5.7 3.8 298 5 298 305 9.6 0 9.7 9.5 08/24/2005 11:00:00 4.7 0.4 5.7 3.4 4.7 0.5 6.1 3.4 296 6 300 305 9.6 0 9.7 9.5 08/24/2005 11:10:00 4.6 0.5 5.7 3 4.6 0.5 5.7 3.4 293 7 294 305 9.7 0 10 9.7 08/24/2005 11:20:00 4.9 0.4 6.1 3.8 4.9 0.4 5.7 3.8 298 7 290 305 9.7 0 10 9.7 08/24/2005 11:30:00 5.1 0.5 6.1 3.8 5.1 0.5 6.1 3.4 298 5 293 305 9.7 0 9.7 9.5 08/24/2005 11:40:00 5.3 0.4 6.1 4.2 5.2 0.4 6.1 3.8 299 6 298 305 9.7 0 10 9.5 08/24/2005 11:50:00 5 0.4 6.1 3.8 5 0.4 5.7 3.8 300 7 297 305 9.6 0 9.7 9.5 08/24/2005 12:00:00 4.7 0.5 5.7 3.4 4.7 0.5 5.7 3.4 301 8 303 305 9.9 0 10.2 9.7 08/24/2005 12:10:00 5 0.4 6.1 3.8 5.1 0.5 6.1 3.8 299 10 305 305 9.9 0 10.2 9.7 08/24/2005 12:20:00 5 0.4 6.1 3.4 5.1 0.4 6.1 4.2 299 11 306 305 9.9 0 10.2 9.7 08/24/2005 12:30:00 4.9 0.5 6.1 3.4 4.9 0.5 6.5 3.4 298 12 288 305 10.2 0.1 10.2 9.7 08/24/2005 12:40:00 5.3 0.4 6.5 4.2 5.3 0.4 6.5 4.2 298 9 301 305 10.2 0 10.5 10 08/24/2005 12:50:00 5.2 0.5 6.1 3.8 5.2 0.5 6.1 3.8 298 5 314 305 10.2 0 10.2 10 08/24/2005 13:00:00 5.1 0.4 6.1 4.2 5.1 0.4 6.1 3.8 298 5 301 305 10.4 0 10.5 10.2 08/24/2005 13:10:00 5.1 0.4 6.5 3.8 5.2 0.4 6.5 4.2 298 5 294 305 10.6 0.1 10.8 10.2 08/24/2005 13:20:00 5.4 0.5 6.8 3.8 5.4 0.4 6.5 4.2 295 7 300 305 10.7 0 11 10.5 08/24/2005 13:30:00 4.7 0.6 6.1 3 4.8 0.6 6.5 3.4 291 8 299 305 10.8 0 11 10.5 08/24/2005 13:40:00 4.7 0.5 5.7 3.4 4.7 0.5 6.1 3.4 295 8 296 305 11 0 11 10.8 08/24/2005 13:50:00 4.4 0.5 5.3 3 4.3 0.5 6.1 2.3 286 10 305 305 11 0 11 10.8 08/24/2005 14:00:00 4.6 0.6 6.1 3 4.5 0.7 6.1 2.6 283 8 279 305 11.1 0 11.3 10.8 08/24/2005 14:10:00 4.6 0.6 6.1 3 4.4 0.6 6.1 2.3 280 9 287 305 11.1 0 11.3 10.8 08/24/2005 14:20:00 4.6 0.5 6.1 3 4.2 0.6 6.1 2.3 277 9 270 305 11.2 0.2 11.6 10.8 08/24/2005 14:30:00 4.3 0.6 6.1 2.6 3.9 0.6 5.7 1.9 270 10 268 305 11.2 0 11.3 11 08/24/2005 14:40:00 4.3 0.6 6.1 2.6 3.9 0.6 5.7 2.3 267 9 269 305 11.1 0 11.3 10.8 08/24/2005 14:50:00 4.3 0.7 5.7 2.3 4 0.6 5.7 2.3 264 11 257 305 11 0 11 10.8 08/24/2005 15:00:00 4.2 0.5 5.7 2.6 3.9 0.7 5.7 2.6 259 11 269 305 11.2 0 11.6 11 08/24/2005 15:10:00 4.1 0.8 6.5 2.3 3.7 0.7 5.7 2.3 260 10 263 305 11.3 0.1 11.6 11 08/24/2005 15:20:00 4.4 0.7 6.1 2.3 3.8 0.6 5.3 2.3 263 9 254 305 11.4 0 11.8 11.3 08/24/2005 15:30:00 5.1 0.7 7.2 2.6 4.4 0.7 6.1 3 264 9 262 305 11.4 0.1 11.6 11 08/24/2005 15:40:00 5 0.6 6.5 3.4 4.2 0.7 6.1 2.3 262 8 258 305 11.2 0.1 11.6 11 08/24/2005 15:50:00 5.1 0.7 6.5 3 4.4 0.6 6.1 3 264 8 262 305 11.3 0 11.6 11 08/24/2005 16:00:00 4.5 0.7 6.1 1.9 4 0.6 5.7 2.6 266 10 259 305 11.4 0 11.6 11 08/24/2005 16:10:00 4.3 0.6 5.7 2.3 3.8 0.6 5.3 2.6 262 9 252 305 11.4 0 11.6 11.3 08/24/2005 16:20:00 4.3 0.7 5.7 1.5 3.8 0.6 5.7 2.3 276 10 251 305 11.6 0.1 11.8 11.3 08/24/2005 16:30:00 4.4 0.6 5.7 2.6 4 0.6 5.7 2.3 273 9 263 305 11.5 0.1 11.8 11.3 08/24/2005 16:40:00 4.1 0.6 5.3 2.3 3.6 0.6 4.9 2.3 267 10 268 305 11.5 0 11.6 11.3 08/24/2005 16:50:00 4 0.6 5.7 2.6 3.7 0.6 5.3 2.3 257 11 254 305 11.6 0 11.8 11.6 08/24/2005 17:00:00 3.9 0.6 5.7 2.3 3.6 0.5 4.9 2.3 258 11 261 305 11.5 0 11.6 11.3 08/24/2005 17:10:00 4.2 0.5 6.1 2.6 4 0.6 5.3 2.3 252 10 234 305 11.7 0 11.8 11.3 08/24/2005 17:20:00 4.2 0.6 5.7 2.3 4 0.6 5.3 2.3 257 10 262 305 11.5 0.1 11.8 11.3 08/24/2005 17:30:00 4.3 0.6 5.3 2.6 4.1 0.7 6.1 2.3 256 9 257 305 11.4 0 11.6 11 08/24/2005 17:40:00 4.7 0.6 6.5 2.3 4.4 0.9 6.1 2.3 254 7 246 305 11.5 0.1 11.8 11.3 08/24/2005 17:50:00 4.8 0.6 6.1 2.6 4.5 0.6 6.5 3 253 8 262 305 11.4 0 11.6 11 08/24/2005 18:00:00 5.1 0.6 6.1 3 4.8 0.7 6.5 2.6 251 7 248 305 11.1 0 11.3 10.8 08/24/2005 18:10:00 5 0.6 6.1 3 4.8 0.7 6.1 3 249 7 247 305 10.8 0 11 10.2 08/24/2005 18:20:00 5 0.6 6.1 3 4.8 0.6 6.1 3.4 250 6 239 305 10.9 0.1 11.3 10.2 08/24/2005 18:30:00 5.1 0.6 6.5 3 4.9 0.6 6.1 3 242 8 254 305 11.3 0 11.6 10.8 08/24/2005 18:40:00 5.2 0.5 6.5 4.2 5 0.5 6.1 3.8 235 6 230 305 11.1 0 11.3 11 08/24/2005 18:50:00 5.1 0.4 6.1 3.8 4.8 0.5 5.7 3.8 236 6 235 305 11.2 0 11.3 11 08/24/2005 19:00:00 4.7 0.5 6.1 3.4 4.6 0.5 5.7 3.4 238 6 238 305 11.1 0 11.3 11 08/24/2005 19:10:00 4.3 0.5 5.3 3 4.2 0.5 5.3 2.6 228 6 235 305 10.9 0 11 10.8 08/24/2005 19:20:00 4.5 0.5 5.7 3 4.3 0.5 5.3 3 224 5 227 305 10.9 0 11 10.8 08/24/2005 19:30:00 4.6 0.5 5.7 3 4.4 0.5 5.7 3.4 225 6 224 305 11.2 0 11.3 11 08/24/2005 19:40:00 5 0.5 6.1 3.4 4.8 0.5 5.7 3.4 232 5 227 305 10.7 0 11 10.5 08/24/2005 19:50:00 5.2 0.5 6.1 3.8 4.9 0.5 6.1 3.8 227 5 224 305 10.8 0 11 10.5 08/24/2005 20:00:00 5.3 0.5 6.5 3.8 5 0.5 6.1 3.8 226 5 217 305 10.6 0 10.8 10.5 08/24/2005 20:10:00 5.8 0.4 6.5 4.6 5.3 0.5 6.5 3.8 225 5 221 305 10.6 0 10.8 10.5 08/24/2005 20:20:00 5.7 0.5 6.8 4.2 5.4 0.5 6.8 3.8 229 5 230 305 10.6 0 10.8 10.2 08/24/2005 20:30:00 5.6 0.5 6.5 4.2 5.2 0.5 6.5 3.4 228 5 235 305 10.5 0.1 10.8 10 08/24/2005 20:40:00 5 0.6 6.5 3.4 4.7 0.6 6.1 3.4 224 6 227 305 10.6 0 10.8 10.5 08/24/2005 20:50:00 4.7 0.5 5.7 3.4 4.4 0.5 5.3 2.6 227 5 235 305 10.3 0 10.5 10.2 08/24/2005 21:00:00 4.6 0.4 5.3 3.4 4.3 0.5 5.3 3 230 6 231 305 10.3 0 10.2 10.2 08/24/2005 21:10:00 4.1 0.4 4.9 3 3.9 0.4 4.9 3 231 6 232 305 10.2 0 10.2 10 08/24/2005 21:20:00 4.2 0.4 4.9 3 3.8 0.4 4.6 3 232 6 219 305 9.9 0 10 9.7 08/24/2005 21:30:00 4.6 0.3 5.3 3 4.2 0.3 4.9 3 241 4 242 305 9.8 0 10 9.7 08/24/2005 21:40:00 4.6 0.4 5.7 3.4 4.2 0.4 5.3 3 243 4 246 305 9.7 0 9.7 9.5 08/24/2005 21:50:00 4.4 0.3 5.3 3.4 3.9 0.4 4.9 2.3 239 3 245 305 9.5 0 9.7 9.5 08/24/2005 22:00:00 4.4 0.3 4.9 3 4 0.4 4.9 2.6 238 3 233 305 9.5 0 9.5 9.5 08/24/2005 22:10:00 4.4 0.3 4.9 3.4 4.1 0.3 4.9 3 241 5 229 305 9.5 0 9.7 9.5 08/24/2005 22:20:00 4.3 0.3 4.9 3 3.9 0.4 4.6 2.6 242 5 248 305 9.3 0 9.5 9.2 08/24/2005 22:30:00 4.7 0.4 5.3 3 4.2 0.4 5.3 3 240 4 242 305 9.3 0 9.5 9.2 08/24/2005 22:40:00 4.8 0.3 5.3 3.8 4.4 0.4 5.3 3 246 3 246 305 9.3 0 9.5 9.2 08/24/2005 22:50:00 4.1 0.4 4.9 3.4 3.8 0.4 4.6 2.6 247 2 247 305 9.2 0 9.5 9.2 08/24/2005 23:00:00 4.3 0.3 4.9 3.4 3.9 0.4 4.9 3 250 2 252 305 9.1 0 9.2 9.2 08/24/2005 23:10:00 4.3 0.2 4.9 3.8 4.1 0.3 4.6 3 247 2 245 305 9.1 0 9.2 9.2 08/24/2005 23:20:00 4.7 0.2 5.3 4.2 4.3 0.3 5.3 3.4 246 3 250 305 9.1 0 9.2 9.2 08/24/2005 23:30:00 4.8 0.3 5.3 4.2 4.4 0.4 5.3 3 249 2 250 305 9.1 0 9.2 8.9 08/24/2005 23:40:00 4.7 0.2 5.3 3.8 4.3 0.3 4.9 3.4 254 2 254 305 8.9 0 9.2 8.9 08/24/2005 23:50:00 4.6 0.2 5.3 4.2 4.1 0.4 4.9 2.6 257 1 257 305 8.8 0 8.9 8.7 08/25/2005 00:00:00 4.5 0.2 4.9 3.8 4 0.3 4.6 3 255 3 257 305 8.7 0 9.2 8.4 08/25/2005 00:10:00 4.7 0.2 5.3 3.8 3.9 0.4 4.9 3 260 2 264 305 8.6 0 8.7 8.4 08/25/2005 00:20:00 4.6 0.2 4.9 4.2 4.3 0.3 4.9 3.4 252 3 261 305 8.7 0 8.9 8.7 08/25/2005 00:30:00 4.3 0.3 4.9 3.4 3.9 0.3 4.6 2.6 248 4 251 305 8.8 0 8.9 8.7 08/25/2005 00:40:00 4.2 0.2 4.6 3.4 3.7 0.3 4.2 2.6 246 3 243 305 8.9 0 8.9 8.9 08/25/2005 00:50:00 4.5 0.3 5.3 3.4 4 0.4 4.9 3 239 3 239 305 8.8 0 8.9 8.9 08/25/2005 01:00:00 5.1 0.4 5.7 3.4 4.5 0.5 5.7 3.4 237 4 231 305 8.8 0 8.9 8.9 08/25/2005 01:10:00 5.3 0.4 6.1 3.8 4.7 0.5 5.7 3 236 4 234 305 8.8 0 8.9 8.7 08/25/2005 01:20:00 5.3 0.3 5.7 4.2 4.9 0.4 5.7 3.8 231 4 239 305 8.6 0 8.9 8.7 08/25/2005 01:30:00 5 0.4 5.7 3.8 4.7 0.4 5.7 3.8 227 4 232 305 8.7 0 8.9 8.7 08/25/2005 01:40:00 4.6 0.5 6.1 3 4.4 0.5 5.7 3 217 8 205 305 8.7 0 8.9 8.7 08/25/2005 01:50:00 4.1 0.5 5.3 3 4.2 0.5 5.3 3 210 7 215 305 8.6 0 8.7 8.4 08/25/2005 02:00:00 3.5 0.5 4.9 2.3 3.4 0.5 4.9 2.3 217 7 215 305 8.4 0 8.7 8.4 08/25/2005 02:10:00 3.4 0.4 4.6 2.6 3.4 0.4 4.9 2.3 209 9 200 305 8.5 0 8.4 8.4 08/25/2005 02:20:00 3.4 0.5 4.6 1.9 3.4 0.5 4.6 2.3 213 9 208 305 8.4 0 8.4 8.4 08/25/2005 02:30:00 4.3 0.6 5.7 3 4.2 0.5 5.7 3 226 8 227 305 8.5 0 8.7 8.4 08/25/2005 02:40:00 4.3 0.4 5.3 3 4 0.4 4.9 3 236 5 230 305 8.6 0 8.7 8.4 08/25/2005 02:50:00 4.1 0.6 5.3 2.6 3.8 0.5 5.3 2.6 242 6 244 305 8.6 0 8.7 8.4 08/25/2005 03:00:00 4.8 0.3 5.3 3.8 4.3 0.4 5.3 3 244 4 249 305 8.6 0 8.7 8.2 08/25/2005 03:10:00 4.3 0.4 4.9 3.4 3.8 0.4 4.9 2.6 243 4 238 305 8.7 0 8.9 8.7 08/25/2005 03:20:00 4.1 0.5 4.9 2.6 3.7 0.4 4.9 2.3 244 5 240 305 8.7 0 8.9 8.7 08/25/2005 03:30:00 5.1 0.4 5.7 3.8 4.4 0.5 5.7 3 245 3 252 305 8.7 0 8.9 8.7 08/25/2005 03:40:00 4.2 0.4 5.3 2.6 3.7 0.4 4.6 2.3 242 5 241 305 8.8 0 8.9 8.7 08/25/2005 03:50:00 4 0.3 4.6 3 3.5 0.3 4.2 2.6 252 6 250 305 8.8 0 8.9 8.7 08/25/2005 04:00:00 4.3 0.3 4.9 3.8 3.4 0.3 4.2 2.6 262 3 263 305 8.6 0 8.9 8.7 08/25/2005 04:10:00 4.7 0.3 5.3 4.2 3.7 0.4 4.9 2.6 262 4 261 305 8.8 0 9.2 8.7 08/25/2005 04:20:00 4.8 0.4 5.7 3.8 3.7 0.5 4.9 2.6 269 4 266 305 9 0 9.2 8.9 08/25/2005 04:30:00 4.4 0.4 5.3 3 3.5 0.5 4.6 2.6 270 7 261 305 9.1 0 9.2 8.9 08/25/2005 04:40:00 4.8 0.3 5.7 4.2 4.3 0.4 5.3 3 280 4 283 305 9.1 0 9.2 8.9 08/25/2005 04:50:00 4.7 0.5 5.7 3.4 4.1 0.5 5.3 2.6 280 5 278 305 9.1 0 9.2 8.9 08/25/2005 05:00:00 4.6 0.5 5.7 3 3.9 0.6 5.3 2.3 276 4 277 305 9 0 9.2 8.9 08/25/2005 05:10:00 4.2 0.4 4.9 3 3.5 0.5 4.6 2.3 273 4 274 305 8.9 0 9.2 8.9 08/25/2005 05:20:00 4.1 0.3 4.6 3 3.1 0.4 3.8 2.3 268 3 275 305 8.8 0 8.9 8.9 08/25/2005 05:30:00 4.3 0.3 4.9 3 3.8 0.4 4.9 2.3 258 3 261 305 8.8 0 8.9 8.7 08/25/2005 05:40:00 4.3 0.3 4.9 3.4 3.8 0.5 4.9 2.6 256 4 251 305 8.8 0 8.9 8.7 08/25/2005 05:50:00 4.7 0.3 5.3 3.8 3.8 0.5 4.9 2.6 262 4 262 305 8.7 0 8.9 8.4 08/25/2005 06:00:00 5.3 0.3 6.1 4.6 4.8 0.5 5.7 3.8 253 4 243 305 8.4 0 8.7 8.4 08/25/2005 06:10:00 5.4 0.4 6.1 4.6 5 0.5 6.1 3.4 248 3 246 305 8.6 0 8.7 8.4 08/25/2005 06:20:00 5.1 0.4 6.1 4.2 4.6 0.4 5.7 3.4 249 5 249 305 8.7 0 8.9 8.7 08/25/2005 06:30:00 4.9 0.4 5.7 3.4 4.4 0.5 5.7 3 251 5 250 305 8.7 0 8.9 8.7 08/25/2005 06:40:00 5.1 0.4 5.7 3.8 4.4 0.5 5.7 3 255 4 254 305 8.6 0 8.9 8.7 08/25/2005 06:50:00 5 0.3 5.7 3.8 4.1 0.5 5.3 2.6 259 3 258 305 8.6 0 8.7 8.4 08/25/2005 07:00:00 4.9 0.4 6.1 3.8 4 0.6 5.3 2.6 258 4 251 305 8.6 0 8.9 8.7 08/25/2005 07:10:00 5.2 0.4 6.1 3.8 4.4 0.5 5.7 3 256 4 254 305 8.6 0 8.7 8.4 08/25/2005 07:20:00 4.9 0.4 6.1 3.4 4 0.5 5.3 2.6 259 5 255 305 8.8 0 8.9 8.7 08/25/2005 07:30:00 4.8 0.5 6.1 2.6 3.7 0.6 5.7 1.9 263 5 256 305 8.8 0 8.9 8.7 08/25/2005 07:40:00 4.3 0.5 5.7 3 3.3 0.5 4.6 1.9 265 5 258 305 8.8 0 8.9 8.9 08/25/2005 07:50:00 4.5 0.5 5.7 3 3.4 0.5 4.9 2.3 266 5 265 305 9 0 9.2 8.9 08/25/2005 08:00:00 4.1 0.5 4.9 2.3 3.1 0.4 4.2 1.9 267 6 268 305 9.1 0 9.2 8.7 08/25/2005 08:10:00 3.9 0.5 5.3 2.3 3 0.5 4.6 1.5 265 6 269 305 9.1 0 9.2 9.2 08/25/2005 08:20:00 4.2 0.5 5.3 2.6 3.4 0.5 4.9 2.3 261 7 264 305 9.2 0 9.2 9.2 08/25/2005 08:30:00 4.1 0.5 4.9 3 3.3 0.6 4.9 1.5 261 7 264 305 9.2 0 9.2 9.2 08/25/2005 08:40:00 4.2 0.5 5.3 2.6 3.7 0.6 4.9 2.3 255 6 258 305 9.2 0 9.2 9.2 08/25/2005 08:50:00 4.5 0.5 5.7 3 3.9 0.5 5.3 2.3 256 6 262 305 9.3 0 9.5 9.2 08/25/2005 09:00:00 4.2 0.5 5.3 2.6 3.5 0.6 4.9 2.3 260 7 257 305 9.3 0 9.5 9.2 08/25/2005 09:10:00 4.1 0.6 5.3 2.3 3.3 0.5 4.6 1.9 264 7 261 305 9.5 0 9.7 9.5 08/25/2005 09:20:00 4.2 0.6 5.7 2.6 3.5 0.5 4.6 2.3 267 8 265 305 9.6 0 9.7 9.5 08/25/2005 09:30:00 4.5 0.6 6.1 2.6 3.6 0.7 5.3 2.3 273 8 270 305 9.7 0 10 9.7 08/25/2005 09:40:00 4.6 0.5 6.1 3 3.7 0.5 4.9 2.3 273 8 277 305 9.9 0 10 9.7 08/25/2005 09:50:00 5 0.6 6.5 2.6 3.9 0.6 5.3 1.9 270 7 272 305 9.9 0 10 9.7 08/25/2005 10:00:00 4.7 0.7 6.1 2.6 3.7 0.6 5.3 2.3 267 8 266 305 10 0 10.2 10 08/25/2005 10:10:00 4.7 0.7 6.5 3 3.9 0.6 5.3 2.3 271 8 282 305 10.2 0 10.2 10 08/25/2005 10:20:00 4.6 0.8 6.1 2.3 4 0.7 5.7 2.3 275 8 271 305 10.2 0 10.2 10.2 08/25/2005 10:30:00 4.8 0.6 6.1 3 4.1 0.6 5.7 2.6 274 6 275 305 10.3 0 10.2 10.2 08/25/2005 10:40:00 4.9 0.5 6.1 3.4 4.5 0.5 6.1 3 281 7 277 305 10.3 0 10.5 10.2 08/25/2005 10:50:00 4.5 0.7 6.1 2.6 4.4 0.6 5.7 3 286 7 293 305 10.5 0 10.8 10.2 08/25/2005 11:00:00 4.6 0.6 6.1 3 4.5 0.6 6.1 3 289 7 283 305 10.6 0 10.8 10.5 08/25/2005 11:10:00 4.1 0.5 5.3 2.6 4.2 0.5 5.7 3 291 8 288 305 10.6 0 10.8 10.5 08/25/2005 11:20:00 4.5 0.5 6.1 3.4 4.6 0.5 6.1 3.4 294 7 287 305 10.6 0 10.8 10.5 08/25/2005 11:30:00 5 0.5 6.1 3.4 4.9 0.5 6.1 3.8 295 7 298 305 10.8 0 10.8 10.5 08/25/2005 11:40:00 4.3 0.5 5.7 3 4.3 0.4 5.3 3.4 294 9 285 305 10.8 0 11 10.5 08/25/2005 11:50:00 4.7 0.4 5.7 3.4 4.7 0.4 5.7 3.4 295 10 294 305 10.8 0 11 10.8 08/25/2005 12:00:00 4.5 0.6 6.5 3 4.5 0.6 6.5 2.3 290 8 303 305 10.8 0 11 10.8 08/25/2005 12:10:00 4.3 0.5 5.7 2.6 4.2 0.5 5.7 3 288 8 292 305 10.8 0 11 10.8 08/25/2005 12:20:00 4.7 0.7 6.5 3 4.5 0.7 6.5 2.6 286 7 296 305 10.8 0 11 10.5 08/25/2005 12:30:00 5.4 0.6 6.8 3.4 5.2 0.6 6.5 3.4 287 11 288 305 10.6 0 10.8 10.5 08/25/2005 12:40:00 6 0.7 7.6 4.2 5.6 0.7 7.2 4.2 284 6 286 305 10.6 0 10.8 10.5 08/25/2005 12:50:00 6 0.6 7.6 3.8 5.5 0.8 7.2 3.8 283 6 294 305 10.5 0 10.5 10.5 08/25/2005 13:00:00 6.2 0.6 7.6 4.2 5.7 0.7 7.2 3.4 284 6 282 305 10.6 0 10.8 10.5 08/25/2005 13:10:00 5.9 0.7 7.2 3.8 5.4 0.8 7.2 3.4 283 6 282 305 10.7 0 10.8 10.5 08/25/2005 13:20:00 5.6 0.6 6.8 3.8 5.2 0.6 6.8 3.8 283 7 287 305 10.7 0 10.8 10.5 08/25/2005 13:30:00 5.5 0.8 7.2 3.8 5.1 0.8 6.8 3.4 283 8 281 305 10.7 0 10.8 10.5 08/25/2005 13:40:00 5.7 0.7 7.2 3.8 5.2 0.8 6.8 3.4 281 6 275 305 10.8 0 10.8 10.5 08/25/2005 13:50:00 5.6 0.6 6.8 4.2 5.1 0.7 6.8 3 282 5 281 305 10.6 0 10.8 10.5 08/25/2005 14:00:00 4.7 0.6 6.5 2.6 4.6 0.7 6.5 2.6 288 8 293 305 10.7 0 10.8 10 08/25/2005 14:10:00 4.9 0.6 6.1 3.4 4.7 0.6 6.1 2.6 287 7 283 305 10.7 0 10.8 10.5 08/25/2005 14:20:00 5.3 0.8 6.8 3.4 5 0.8 7.2 2.6 287 9 288 305 10.9 0.1 11 10.5 08/25/2005 14:30:00 5.8 0.7 7.2 4.6 5.5 0.7 7.2 3.8 289 6 294 305 11 0.1 11.3 10.8 08/25/2005 14:40:00 5.8 0.9 7.6 3.8 5.7 0.9 7.6 3.8 294 12 298 305 11.8 0.1 11.8 11.3 08/25/2005 14:50:00 6.5 0.7 8 4.2 6.2 0.7 8.4 4.6 298 9 293 305 11.6 0 11.8 11.3 08/25/2005 15:00:00 6.2 0.7 8 4.9 6.1 0.8 8.4 4.6 301 9 301 305 11.8 0 11.8 11.6 08/25/2005 15:10:00 6 0.5 7.2 4.6 5.8 0.6 7.2 3.8 295 6 291 305 11.9 0 12.1 11.6 08/25/2005 15:20:00 6.1 0.7 8 3.8 5.8 0.7 7.6 4.2 296 14 305 305 11.9 0 12.1 11.6 08/25/2005 15:30:00 6.3 0.8 8.4 4.6 6.1 0.9 8.8 4.2 290 8 286 305 12 0 12.4 11.8 08/25/2005 15:40:00 6.7 0.7 8 4.2 6.5 0.7 8 4.6 288 8 296 305 12 0 12.4 11.8 08/25/2005 15:50:00 6.4 0.7 8 3.8 6.1 0.7 7.6 3.8 285 8 294 305 12.1 0 12.4 12.1 08/25/2005 16:00:00 6.7 0.7 8.4 4.6 6.1 0.8 8 3.8 279 8 279 305 12 0 12.4 11.8 08/25/2005 16:10:00 6.1 1 8.8 4.2 5.6 0.8 8 3.8 280 8 277 305 12.2 0 12.4 11.8 08/25/2005 16:20:00 6.8 0.7 8.4 4.6 6.4 0.7 8 4.6 283 7 277 305 12.2 0 12.4 11.8 08/25/2005 16:30:00 6.2 0.7 7.6 4.6 6 0.7 7.6 4.2 285 9 284 305 12.1 0.1 12.4 11.8 08/25/2005 16:40:00 6.4 0.7 8 4.6 5.8 0.7 8 4.2 277 7 270 305 12 0 12.1 11.8 08/25/2005 16:50:00 6.2 1 8.4 3.8 5.8 1 7.6 3 281 6 282 305 11.8 0 12.1 11.6 08/25/2005 17:00:00 6.3 0.9 8.8 3.8 5.5 0.9 7.6 3 275 8 260 305 11.9 0 11.8 11.8 08/25/2005 17:10:00 6.6 0.9 9.1 4.6 5.6 0.9 8 2.6 273 8 282 305 12 0.1 12.4 11.6 08/25/2005 17:20:00 6.8 1 8.8 3.8 5.8 0.9 7.6 3.4 273 8 273 305 12.2 0 12.4 11.8 08/25/2005 17:30:00 6.5 1.1 8.4 4.2 5.5 1 7.6 2.6 271 9 272 305 12.1 0 12.4 11.8 08/25/2005 17:40:00 6.3 1.1 8.4 3.8 5.2 1 7.6 2.6 272 9 275 305 11.8 0.3 12.4 11.3 08/25/2005 17:50:00 6.2 0.9 8 4.2 5.3 1 7.6 3 278 8 272 305 11.5 0 11.8 11.3 08/25/2005 18:00:00 6.5 0.8 8.4 4.2 5.5 0.8 7.6 3.4 277 7 270 305 11.4 0 11.6 11.3 08/25/2005 18:10:00 6.3 0.9 8 3.8 5.3 0.9 7.2 2.6 275 9 271 305 11.4 0 11.6 11.3 08/25/2005 18:20:00 6.5 0.9 8 4.6 5.7 0.9 7.6 3.8 277 6 269 305 11.4 0 11.6 11.3 08/25/2005 18:30:00 6.6 1 8.4 4.2 5.5 0.8 7.2 3.4 273 8 273 305 11.3 0 11.3 11 08/25/2005 18:40:00 6 0.8 7.6 3.4 4.9 0.8 6.5 2.6 271 8 273 305 11.3 0 11.3 11.3 08/25/2005 18:50:00 6.3 1.1 8.8 4.2 5.1 1 7.6 3 270 8 272 305 11.4 0 11.6 11.3 08/25/2005 19:00:00 6.5 1 8.4 3.8 5.2 0.9 7.2 2.3 270 8 275 305 11.2 0 11.3 11 08/25/2005 19:10:00 6.4 1 8.4 3.4 5.1 0.9 7.2 3 266 8 270 305 11.3 0 11.3 11 08/25/2005 19:20:00 6.8 1.1 9.1 3.8 5.3 1 8 3 267 7 273 305 11.4 0 11.6 11.3 08/25/2005 19:30:00 6 1 8.4 3.4 5 0.9 8 2.6 265 10 258 305 11.2 0.1 11.6 10.8 08/25/2005 19:40:00 6.4 0.9 8.8 4.2 5.2 0.8 7.6 3.4 263 9 252 305 10.8 0 11 10.8 08/25/2005 19:50:00 6.7 0.9 8.4 4.2 5.4 0.9 7.6 3.4 262 7 259 305 10.7 0 11 10.5 08/25/2005 20:00:00 7 0.8 8.8 4.2 5.5 0.8 8 3.4 263 6 273 305 10.8 0 11 10.5 08/25/2005 20:10:00 6.1 0.8 8.4 3.8 5 0.8 6.8 3 265 7 278 305 10.5 0 10.8 10.5 08/25/2005 20:20:00 5.9 1 8 3 4.8 0.8 6.5 3 265 8 268 305 10.4 0 10.5 10.2 08/25/2005 20:30:00 6.1 0.8 8 3.8 5.1 0.7 6.8 3 263 7 266 305 10.6 0 10.8 10.5 08/25/2005 20:40:00 6.8 0.8 8.4 4.9 5.5 0.7 7.6 3.8 262 6 265 305 10.6 0.1 10.8 10.2 08/25/2005 20:50:00 6.3 0.9 8.4 3.8 5.1 0.8 7.6 3 262 7 265 305 10.5 0 10.8 10.2 08/25/2005 21:00:00 6.8 0.8 8.8 3.8 5.4 0.7 7.2 3.4 262 6 265 305 10.4 0 10.5 10.2 08/25/2005 21:10:00 6.1 0.8 8.4 4.2 4.9 0.8 6.8 3 264 7 262 305 10.4 0 10.5 10.2 08/25/2005 21:20:00 6.3 0.8 8 4.2 5.1 0.7 7.2 3 263 6 263 305 10.3 0 10.5 10.2 08/25/2005 21:30:00 6.9 0.9 9.1 4.2 5.4 0.9 8 3 263 6 259 305 10.2 0 10.2 10 08/25/2005 21:40:00 6.8 0.7 8.8 4.6 5.1 0.8 7.2 3.4 266 7 266 305 10.1 0 10.2 10 08/25/2005 21:50:00 6.5 0.8 8.4 4.2 5.2 0.8 7.2 3 264 7 270 305 10 0 10.2 10 08/25/2005 22:00:00 6.9 0.7 8.4 4.9 5.4 0.7 7.2 3.8 263 5 263 305 9.8 0 10 9.7 08/25/2005 22:10:00 7.1 0.7 9.1 5.3 5.7 0.7 7.6 3.4 263 5 262 305 9.7 0 10 9.7 08/25/2005 22:20:00 7.5 0.8 9.1 4.6 6 0.8 8.4 3.8 260 6 261 305 9.7 0 9.7 9.7 08/25/2005 22:30:00 7.6 0.7 9.5 5.3 6.3 0.8 8.8 3.8 256 6 267 305 9.7 0 10 9.7 08/25/2005 22:40:00 7.6 0.9 9.5 4.9 6.6 0.9 8.8 3.8 254 5 251 305 9.7 0 10 9.7 08/25/2005 22:50:00 7.8 0.8 9.5 5.3 6.9 1 9.1 4.2 252 5 238 305 9.7 0 10 9.7 08/25/2005 23:00:00 7.8 1 9.9 5.3 6.8 1 9.9 3.8 251 6 254 305 9.7 0 10 9.5 08/25/2005 23:10:00 8 0.9 9.9 5.3 6.9 1.1 9.5 4.2 252 6 248 305 9.7 0 10 9.7 08/25/2005 23:20:00 8.3 1 10.7 5.7 7.5 1.1 9.9 4.9 252 5 250 305 9.7 0 10 9.7 08/25/2005 23:30:00 8.1 0.9 9.9 5.3 7.1 1 9.5 4.6 252 5 256 305 9.7 0 10 9.7 08/25/2005 23:40:00 8 1 9.9 4.9 7.1 1.1 9.5 3.8 252 5 252 305 9.7 0 10 9.7 08/25/2005 23:50:00 7.8 0.9 9.9 4.2 7 1 9.5 3.8 252 5 254 305 9.7 0 9.7 9.7 08/26/2005 00:00:00 8.5 0.8 9.9 6.1 7.5 1 9.9 4.9 252 5 255 305 9.7 0 10.2 9.2 08/26/2005 00:10:00 8.2 0.7 9.9 6.1 7.5 0.8 9.5 4.9 248 5 252 305 9.7 0 10 9.7 08/26/2005 00:20:00 7.9 0.8 9.9 5.7 7.1 0.9 9.1 4.9 244 5 243 305 9.7 0 9.7 9.7 08/26/2005 00:30:00 7.8 0.8 9.5 5.7 7.1 0.9 9.1 4.9 246 4 247 305 9.7 0 9.7 9.7 08/26/2005 00:40:00 7.4 0.8 9.1 4.9 6.8 0.9 9.1 4.2 250 5 254 305 9.7 0 9.7 9.5 08/26/2005 00:50:00 7.7 0.7 9.1 5.7 7 0.8 8.8 4.6 249 6 258 305 9.7 0 9.7 9.5 08/26/2005 01:00:00 7.4 0.7 9.1 5.3 6.7 0.7 8.8 4.9 249 6 237 305 9.6 0 9.7 9.5 08/26/2005 01:10:00 7.5 0.7 9.5 5.3 6.9 0.8 9.1 4.6 249 6 251 305 9.5 0 9.7 9.5 08/26/2005 01:20:00 7.4 0.8 8.8 4.6 6.5 0.9 9.1 4.2 253 6 252 305 9.5 0 9.7 9.5 08/26/2005 01:30:00 7.5 0.7 8.8 5.3 6.4 0.9 8.8 4.2 254 5 261 305 9.6 0 9.7 9.5 08/26/2005 01:40:00 7.6 0.7 9.1 5.3 6.5 0.8 8.8 4.2 256 6 255 305 9.5 0 9.7 9.5 08/26/2005 01:50:00 7.6 0.6 9.1 5.7 6.5 0.8 8.4 4.2 255 5 256 305 9.5 0 9.7 9.5 08/26/2005 02:00:00 7.8 0.8 10.3 5.3 6.6 0.8 9.1 4.2 256 6 259 305 9.5 0 9.7 8.9 08/26/2005 02:10:00 7.9 0.7 9.5 5.7 6.4 0.8 8.4 4.6 259 5 256 305 9.5 0 9.7 9.5 08/26/2005 02:20:00 7 0.7 8.4 5.3 5.8 0.8 8 3.4 256 5 258 305 9.3 0 9.5 9.2 08/26/2005 02:30:00 7.6 0.7 9.1 5.7 6.3 0.9 8.4 4.2 257 5 260 305 9.2 0 9.5 9.2 08/26/2005 02:40:00 7.5 0.6 8.8 5.3 6.3 0.8 8 4.2 255 5 263 305 9.2 0 9.5 9.2 08/26/2005 02:50:00 7.3 0.7 8.8 5.3 6.3 0.9 9.1 4.2 253 5 260 305 9.3 0 9.5 9.2 08/26/2005 03:00:00 7.6 0.6 9.1 5.3 6.6 0.9 8.4 4.6 252 5 249 305 9.3 0 9.5 9.2 08/26/2005 03:10:00 7.8 0.7 9.1 5.3 6.9 0.9 8.8 4.9 251 4 251 305 9.3 0 9.5 9.2 08/26/2005 03:20:00 7.5 0.6 9.1 5.7 6.7 0.7 8.8 4.9 252 5 256 305 9.2 0 9.5 9.2 08/26/2005 03:30:00 8 0.5 9.1 6.1 7.1 0.7 8.8 4.2 251 4 254 305 9.2 0 9.5 9.2 08/26/2005 03:40:00 7.2 0.7 8.8 5.7 6.5 0.8 8.4 4.6 249 5 249 305 9.2 0 9.5 9.2 08/26/2005 03:50:00 7.1 0.6 8.4 5.3 6.5 0.7 8 4.2 247 5 247 305 9.2 0 9.5 9.2 08/26/2005 04:00:00 7.3 0.6 8.4 5.3 6.5 0.6 8 4.6 246 4 242 305 9.2 0 9.2 9.2 08/26/2005 04:10:00 7.2 0.6 8.8 5.3 6.3 0.7 8 4.2 246 4 245 305 9.2 0 9.2 9.2 08/26/2005 04:20:00 7.4 0.6 8.8 4.9 6.7 0.7 8.4 4.2 245 4 247 305 9.2 0 9.5 9.2 08/26/2005 04:30:00 7.3 0.6 8.4 4.9 6.6 0.7 8.4 3.8 248 5 248 305 9.2 0 9.5 9.2 08/26/2005 04:40:00 6.9 0.5 8 5.3 6.3 0.6 8 4.6 250 4 251 305 9.3 0 9.5 9.2 08/26/2005 04:50:00 7.6 0.7 9.1 4.9 7 0.8 8.8 4.2 250 5 261 305 9.3 0 9.5 9.2 08/26/2005 05:00:00 7.5 0.7 9.1 5.3 6.6 1 8.8 4.2 253 5 247 305 9.4 0 9.7 9.2 08/26/2005 05:10:00 7.9 0.7 9.1 5.7 7.2 0.9 9.1 4.6 253 4 253 305 9.3 0 9.5 9.2 08/26/2005 05:20:00 8 0.6 9.1 6.5 7.2 0.8 9.1 5.3 251 5 252 305 9.2 0 9.5 9.2 08/26/2005 05:30:00 7.1 0.9 9.1 4.9 6.5 1 8.8 4.6 253 6 261 305 9.2 0 9.5 9.2 08/26/2005 05:40:00 7.8 0.5 8.8 6.5 6.7 0.8 8.8 3.8 257 6 259 305 9.3 0 9.5 9.2 08/26/2005 05:50:00 7.3 0.6 8.8 5.7 6.3 0.9 8.8 4.2 254 6 250 305 9.3 0 9.5 9.2 08/26/2005 06:00:00 7.4 0.6 8.8 5.3 6.6 0.7 8.4 4.6 253 5 257 305 9.2 0 9.5 9.2 08/26/2005 06:10:00 7.5 0.8 9.9 4.9 7 0.8 9.1 4.6 251 5 250 305 9.4 0 9.5 9.2 08/26/2005 06:20:00 6 1 7.6 3 5.3 1 8 3 255 7 257 305 9.3 0 9.5 9.2 08/26/2005 06:30:00 6.8 0.6 8 5.3 6 0.7 8 4.2 252 6 258 305 9.4 0 9.7 9.2 08/26/2005 06:40:00 7 0.7 9.1 5.3 6.5 0.8 8.4 4.2 246 6 236 305 9.5 0 9.7 9.5 08/26/2005 06:50:00 7.7 0.7 9.5 5.3 7.1 0.7 9.1 4.9 238 6 249 305 9.7 0 9.7 9.5 08/26/2005 07:00:00 6.8 0.7 8.8 5.3 6.2 0.8 8 4.2 245 4 242 305 9.8 0 10 9.7 08/26/2005 07:10:00 5.9 0.5 7.2 4.6 5.4 0.5 7.2 4.2 247 4 251 305 9.7 0 10 9.7 08/26/2005 07:20:00 5.1 0.4 6.1 4.2 4.7 0.4 5.7 3.4 246 3 246 305 9.7 0 9.7 9.5 08/26/2005 07:30:00 4.8 0.4 6.1 3.8 4.5 0.4 5.3 3.4 244 3 242 305 9.6 0 9.7 9.5 08/26/2005 07:40:00 4.7 0.4 5.7 3.4 4.3 0.4 5.3 3.4 238 4 241 305 9.7 0 9.7 9.5 08/26/2005 07:50:00 4.6 0.4 5.7 3.4 4.3 0.4 5.3 3.4 236 5 235 305 9.7 0 10 9.7 08/26/2005 08:00:00 4.7 0.3 5.3 3.8 4.1 0.4 5.3 3 238 4 238 305 9.8 0 10 9.7 08/26/2005 08:10:00 4.5 0.3 5.3 3.8 4.1 0.3 4.9 3 244 4 247 305 9.9 0 10 9.7 08/26/2005 08:20:00 4.3 0.4 4.9 3.4 3.9 0.4 4.9 3 250 3 247 305 9.7 0 10 9.7 08/26/2005 08:30:00 4.7 0.4 5.7 3.4 4.3 0.5 5.7 2.6 251 4 253 305 9.7 0 9.7 9.7 08/26/2005 08:40:00 5 0.4 6.1 4.2 4.3 0.5 5.7 3 254 5 260 305 9.7 0 9.7 9.7 08/26/2005 08:50:00 5 0.4 5.7 3.4 4.4 0.5 5.7 3 255 4 256 305 9.7 0 9.7 9.7 08/26/2005 09:00:00 5.3 0.4 6.5 4.2 4.8 0.5 5.7 3.4 249 5 249 305 9.9 0 10 9.7 08/26/2005 09:10:00 5.3 0.5 6.1 3.4 4.8 0.6 6.1 3 250 6 251 305 10 0 10.2 10 08/26/2005 09:20:00 5.7 0.4 6.8 4.2 5.3 0.5 6.5 3.8 246 5 245 305 10 0 10.2 10 08/26/2005 09:30:00 5.7 0.5 6.8 4.2 5.2 0.5 6.5 3.8 243 5 245 305 10.2 0 10.2 10 08/26/2005 09:40:00 5.5 0.5 6.5 4.2 5 0.5 6.1 3.4 237 5 238 305 10.4 0 10.5 10.2 08/26/2005 09:50:00 4.8 0.6 6.1 3.4 4.4 0.6 5.7 3 239 5 238 305 10.4 0 10.5 10.2 08/26/2005 10:00:00 4.6 0.5 5.7 2.3 4.3 0.5 5.3 2.6 241 5 240 305 10.5 0 10.8 10.5 08/26/2005 10:10:00 4.9 0.5 6.1 3.4 4.6 0.5 5.7 3.4 237 6 243 305 10.8 0 11 10.5 08/26/2005 10:20:00 4.9 0.4 5.7 3.8 4.6 0.4 6.1 3.4 232 5 245 305 10.8 0 11 10.8 08/26/2005 10:30:00 5.5 0.4 6.5 4.2 5.1 0.5 6.1 3.8 230 5 238 305 10.8 0 11 10.8 08/26/2005 10:40:00 5.3 0.6 6.5 3.8 4.9 0.6 6.5 3.4 227 6 232 305 11 0 11.3 10.8 08/26/2005 10:50:00 5.4 0.5 6.5 3.8 4.9 0.5 6.1 3.8 229 6 233 305 10.8 0 11 10.8 08/26/2005 11:00:00 5 0.5 6.5 3.4 4.6 0.5 6.1 3.4 227 6 224 305 10.9 0 11 10.8 08/26/2005 11:10:00 5.7 0.5 7.2 4.2 5.2 0.6 6.5 3.4 220 5 226 305 11 0 11 10.8 08/26/2005 11:20:00 6.2 0.6 7.6 4.2 5.7 0.7 7.2 3.8 220 5 218 305 11 0 11 10.8 08/26/2005 11:30:00 6.1 0.6 7.6 4.6 5.7 0.6 7.6 4.2 212 7 215 305 10.8 0 11 10.5 08/26/2005 11:40:00 6 0.4 6.8 4.6 5.9 0.5 6.8 4.2 204 4 197 305 10.4 0 10.8 10.2 08/26/2005 11:50:00 6.4 0.4 7.6 5.3 6.4 0.4 7.2 4.9 207 3 209 305 10.4 0 10.5 10.2 08/26/2005 12:00:00 6.4 0.4 7.2 4.9 6.3 0.5 7.6 4.6 209 4 211 305 10.4 0 10.5 10.2 08/26/2005 12:10:00 5.7 0.5 6.8 3.4 5.7 0.5 6.8 4.2 210 5 213 305 10.6 0 10.8 10.5 08/26/2005 12:20:00 5.8 0.5 6.8 4.6 5.6 0.6 6.8 3.8 205 5 205 305 10.6 0 10.8 10.5 08/26/2005 12:30:00 5.1 0.6 6.8 3.4 5.1 0.6 6.8 3.4 211 7 208 305 10.6 0 10.8 10.5 08/26/2005 12:40:00 4.8 0.6 6.1 3 4.6 0.6 6.1 3 221 8 226 305 11 0 11.3 10.8 08/26/2005 12:50:00 4.9 0.6 6.1 3 4.6 0.6 5.7 2.6 224 7 215 305 11.4 0.1 11.6 11.3 08/26/2005 13:00:00 5.1 0.6 6.1 3.4 4.8 0.6 6.5 3.4 223 6 231 305 11.4 0 11.6 11.3 08/26/2005 13:10:00 5.5 0.4 6.5 4.2 5.3 0.5 6.5 3.8 219 5 221 305 11.4 0 11.3 11.3 08/26/2005 13:20:00 4.6 0.5 6.1 2.6 4.5 0.5 5.7 3 208 6 213 305 11.4 0 11.6 11.3 08/26/2005 13:30:00 4.7 0.5 5.7 3 4.6 0.5 5.7 3 209 7 214 305 11.6 0 11.8 11.3 08/26/2005 13:40:00 4.3 0.5 5.3 2.6 4.3 0.5 5.7 3 212 7 218 305 11.8 0 12.1 11.6 08/26/2005 13:50:00 4.5 0.5 5.7 2.6 4.3 0.5 5.7 3 213 7 220 305 11.9 0 12.1 11.6 08/26/2005 14:00:00 4.3 0.5 5.3 2.6 4.1 0.5 5.3 3 214 7 215 305 12 0 12.1 11.6 08/26/2005 14:10:00 5 0.5 6.1 3.4 4.7 0.5 5.7 3.4 217 6 212 305 11.8 0 12.1 11.6 08/26/2005 14:20:00 4.7 0.5 5.7 3 4.5 0.5 5.7 2.6 221 7 221 305 12 0 12.1 11.8 08/26/2005 14:30:00 4.5 0.5 5.7 3.4 4.4 0.5 5.7 3 221 8 218 305 12.2 0 12.4 12.1 08/26/2005 14:40:00 4.3 0.5 5.7 2.6 4.2 0.5 5.3 3 222 7 225 305 12.1 0 12.4 11.8 08/26/2005 14:50:00 4.3 0.6 6.1 2.6 4.3 0.5 5.7 2.6 224 9 227 305 12.3 0 12.4 11.8 08/26/2005 15:00:00 4.7 0.5 6.1 3.4 4.6 0.5 5.7 3 226 7 223 305 12.4 0 12.9 12.1 08/26/2005 15:10:00 5.2 0.6 6.5 3.4 5.1 0.6 6.1 3.4 228 6 234 305 12 0.2 12.4 11.6 08/26/2005 15:20:00 5.6 0.6 6.8 4.2 5.4 0.6 6.8 3.8 234 6 238 305 11.7 0 11.8 11.6 08/26/2005 15:30:00 5.8 0.6 6.8 4.2 5.5 0.6 6.8 3.8 238 6 239 305 12 0 12.1 11.6 08/26/2005 15:40:00 6 0.6 7.2 4.2 5.7 0.6 6.8 4.2 238 5 245 305 11.9 0 11.8 11.8 08/26/2005 15:50:00 5.8 0.7 7.2 3.8 5.6 0.6 7.2 3.8 237 6 236 305 11.9 0 12.1 11.6 08/26/2005 16:00:00 5.7 0.6 7.2 4.2 5.4 0.6 7.2 3.8 237 5 239 305 11.9 0 12.1 11.6 08/26/2005 16:10:00 5.5 0.6 6.8 3.8 5.3 0.6 6.5 3.8 235 6 231 305 11.8 0 12.1 11.6 08/26/2005 16:20:00 5.4 0.6 6.5 3.8 5.2 0.6 6.5 3.8 232 6 242 305 11.9 0 12.1 11.6 08/26/2005 16:30:00 5.2 0.6 6.5 3.4 5.1 0.5 6.5 3.4 228 6 231 305 11.9 0 12.1 11.6 08/26/2005 16:40:00 5.1 0.6 6.1 3.4 4.9 0.5 6.5 3.8 226 6 224 305 11.8 0 12.1 11.6 08/26/2005 16:50:00 5.2 0.5 6.5 4.2 5.1 0.6 6.5 3.8 227 6 227 305 11.6 0 11.8 11.3 08/26/2005 17:00:00 5.1 0.7 6.5 3.4 4.9 0.6 6.5 3.4 224 7 224 305 11.9 0 12.1 11.6 08/26/2005 17:10:00 5.4 0.7 7.2 3.8 5.3 0.6 6.8 3.8 220 6 230 305 11.7 0 11.8 11.3 08/26/2005 17:20:00 5.3 0.5 6.5 3.8 5.2 0.6 6.5 3.8 220 5 218 305 11.8 0 11.8 11.6 08/26/2005 17:30:00 5.1 0.6 6.5 3.4 5 0.6 6.5 3.4 216 6 217 305 11.8 0 12.1 11.6 08/26/2005 17:40:00 5.6 0.5 7.2 3.8 5.5 0.6 6.8 3.4 208 7 210 305 11.9 0 12.1 11.6 08/26/2005 17:50:00 5.8 0.5 6.8 3.8 5.8 0.6 7.2 3.8 207 5 205 305 11.5 0.2 11.8 11.3 08/26/2005 18:00:00 5.7 0.9 8 3.4 5.5 0.8 8 3.8 213 6 217 305 11.2 0 11.3 11 08/26/2005 18:10:00 6.5 0.6 7.6 4.6 6.2 0.7 7.6 4.6 219 5 217 305 11.3 0 11.3 11 08/26/2005 18:20:00 6.9 0.5 8 5.3 6.7 0.6 8 4.2 218 3 219 305 11 0 11.3 10.8 08/26/2005 18:30:00 6.5 0.6 7.6 4.9 6.1 0.7 7.6 4.2 216 5 210 305 11 0 11 10.8 08/26/2005 18:40:00 6.1 0.6 7.6 4.2 5.9 0.6 7.2 4.2 208 6 212 305 10.9 0 11 10.5 08/26/2005 18:50:00 6.1 0.4 6.8 4.9 6 0.4 7.2 4.9 202 3 198 305 10.5 0.1 10.8 10.2 08/26/2005 19:00:00 6.5 0.3 7.2 5.7 6.4 0.5 7.6 4.9 202 3 203 305 10.3 0 10.5 10.2 08/26/2005 19:10:00 6.9 0.5 8.4 5.7 6.7 0.5 8 5.3 205 3 202 305 10.4 0 10.5 10.2 08/26/2005 19:20:00 6.3 0.7 7.6 4.6 6.2 0.7 7.6 4.2 206 5 210 305 10.3 0 10.5 10.2 08/26/2005 19:30:00 5.9 0.7 7.6 3.8 5.5 0.7 7.2 3.8 227 6 231 305 10.6 0 10.8 10.2 08/26/2005 19:40:00 5.5 0.5 6.8 3.8 5.2 0.6 6.5 3.8 232 5 236 305 10.8 0 10.8 10.8 08/26/2005 19:50:00 5.3 0.5 6.8 3.8 4.9 0.5 6.1 3.4 236 6 227 305 10.8 0 10.8 10.8 08/26/2005 20:00:00 5.1 0.5 6.1 3.8 4.9 0.5 6.1 3.4 238 5 230 305 10.8 0 10.8 10.8 08/26/2005 20:10:00 5.3 0.5 6.5 3.8 5 0.5 6.1 3.8 237 4 245 305 10.7 0 10.8 10.5 08/26/2005 20:20:00 5.8 0.5 7.2 4.6 5.4 0.5 6.8 3.8 239 5 236 305 10.6 0 10.8 10.5 08/26/2005 20:30:00 6.6 0.6 8 4.6 6.1 0.7 7.6 4.6 239 5 241 305 10.4 0 10.5 10.2 08/26/2005 20:40:00 7.2 0.7 9.1 4.9 6.6 0.8 8.4 4.2 243 6 244 305 10.3 0 10.5 10.2 08/26/2005 20:50:00 6.6 0.6 8 4.9 5.8 0.7 8 3.4 248 6 252 305 10.5 0 10.5 10.5 08/26/2005 21:00:00 6.6 0.6 8.4 4.6 5.7 0.6 7.2 4.2 241 5 239 305 10.5 0 10.5 10.5 08/26/2005 21:10:00 6.8 0.6 8 4.6 6 0.7 7.6 4.2 241 7 252 305 10.5 0 10.5 10.5 08/26/2005 21:20:00 7.5 0.6 8.8 5.7 6.7 0.8 8.4 4.6 238 5 239 305 10.3 0 10.5 10.2 08/26/2005 21:30:00 6.5 0.8 8.4 4.2 5.8 0.9 8 3.4 240 5 238 305 10.2 0 10.2 10.2 08/26/2005 21:40:00 6.1 0.9 7.6 4.2 5.4 0.8 6.8 3.4 235 6 238 305 10.2 0 10.2 10 08/26/2005 21:50:00 6.5 0.5 8 5.3 5.9 0.6 7.6 4.2 231 4 228 305 10.1 0 10.2 10 08/26/2005 22:00:00 7 0.7 8 4.9 6.2 0.8 7.6 4.6 228 4 225 305 10 0 10.2 10 08/26/2005 22:10:00 6 0.6 7.2 4.2 5.3 0.7 6.8 3.8 228 5 238 305 10.1 0 10.2 10 08/26/2005 22:20:00 6 0.7 8 4.2 5.4 0.6 7.2 3.4 234 6 236 305 10 0 10.2 10 08/26/2005 22:30:00 4.9 0.5 6.1 3.4 4.4 0.6 6.1 3 240 7 234 305 10 0 10.2 10 08/26/2005 22:40:00 4.5 0.6 5.7 3 4.2 0.6 5.7 2.6 230 6 231 305 10 0 10.2 10 08/26/2005 22:50:00 5.3 0.6 6.1 3.4 4.9 0.6 6.1 3 236 8 233 305 10 0 10.2 10 08/26/2005 23:00:00 5.6 0.5 6.5 3.8 5.3 0.6 6.5 3.8 218 4 221 305 9.9 0 10 9.7 08/26/2005 23:10:00 5.7 0.6 6.8 3.4 5.4 0.6 6.8 3.8 220 5 213 305 9.8 0 10 9.7 08/26/2005 23:20:00 4.8 0.4 5.7 3 4.7 0.4 5.7 3 220 5 219 305 9.7 0 9.7 9.7 08/26/2005 23:30:00 4.8 0.5 6.1 3.4 4.5 0.6 5.7 3 226 4 225 305 9.9 0 10 9.7 08/26/2005 23:40:00 4.4 0.4 5.3 3 4.2 0.5 5.7 3 214 5 217 305 9.9 0 10 10 08/26/2005 23:50:00 4.9 0.5 6.5 3.8 4.7 0.5 6.1 3.4 212 5 208 305 9.9 0 10 9.7 08/27/2005 00:00:00 4.5 0.8 6.5 2.6 4.3 0.8 6.1 3 220 7 214 305 9.9 0 10.2 9.7 08/27/2005 00:10:00 4.4 0.6 6.5 3 4.5 0.6 6.1 3 203 6 198 305 9.9 0 10 9.7 08/27/2005 00:20:00 5.5 0.5 6.5 3.4 5.5 0.6 6.5 3.8 198 5 197 305 9.7 0 10 9.5 08/27/2005 00:30:00 5.4 0.4 6.1 4.2 5.4 0.4 6.5 4.6 196 4 198 305 9.7 0 9.7 9.5 08/27/2005 00:40:00 5.1 0.4 6.1 3.8 5.3 0.5 6.1 3.8 194 5 199 305 9.7 0 9.7 9.5 08/27/2005 00:50:00 4.9 0.5 5.7 3 5 0.6 6.1 3.4 192 4 190 305 9.7 0 9.7 9.5 08/27/2005 01:00:00 4.2 0.6 5.3 2.6 4.6 0.5 5.7 3.4 189 5 193 305 9.7 0 9.7 9.7 08/27/2005 01:10:00 4.4 0.6 5.7 2.6 4.8 0.5 6.1 3.4 189 4 188 305 9.6 0 9.7 9.5 08/27/2005 01:20:00 4.8 0.3 5.7 3.4 5 0.4 5.7 3.8 193 5 190 305 9.7 0 9.7 9.7 08/27/2005 01:30:00 5.3 0.4 6.1 4.6 5.4 0.4 6.5 3.8 194 4 198 305 9.7 0 10 9.7 08/27/2005 01:40:00 5.6 0.4 6.5 4.6 5.8 0.5 6.8 4.2 190 3 188 305 9.7 0 10 9.7 08/27/2005 01:50:00 5.3 0.3 6.1 4.2 5.4 0.4 6.5 3.8 190 3 188 305 9.7 0 10 9.7 08/27/2005 02:00:00 4 0.9 6.1 2.3 5.2 0.6 6.5 3.4 180 7 188 305 9.9 0 10 9.7 08/27/2005 02:10:00 3.4 0.8 5.7 1.9 4.9 0.7 6.8 3 170 8 181 305 9.9 0 10 9.7 08/27/2005 02:20:00 4.3 0.8 6.5 2.3 4.8 0.5 6.1 3.8 161 6 161 305 9.5 0 9.7 9.5 08/27/2005 02:30:00 4.4 1 6.8 1.9 5.3 0.6 6.8 3.8 164 5 163 305 9.3 0 9.5 9.2 08/27/2005 02:40:00 3.3 0.6 5.3 1.9 4.9 0.4 6.1 3.8 170 6 181 305 9.2 0 9.5 9.2 08/27/2005 02:50:00 3.5 0.9 5.7 1.5 4.6 0.4 5.7 3.4 168 8 158 305 9.2 0 9.5 9.2 08/27/2005 03:00:00 4.3 0.8 6.5 2.3 5.2 0.5 6.5 3.8 163 6 157 305 9.2 0 9.2 9.2 08/27/2005 03:10:00 4.1 0.9 6.8 2.3 5 0.6 6.5 3.4 164 7 160 305 9.2 0 9.2 9.2 08/27/2005 03:20:00 3.8 0.8 6.5 2.3 5.3 0.7 7.6 3.4 169 6 177 305 9.2 0 9.5 9.2 08/27/2005 03:30:00 4.7 1 7.2 2.6 5.7 0.7 8 3.8 163 7 149 305 9.2 0 9.5 9.2 08/27/2005 03:40:00 6 1.2 9.5 3 6.5 1 8.8 4.2 159 8 161 305 9.2 0 9.2 9.2 08/27/2005 03:50:00 7.7 0.9 9.9 5.3 7.4 0.8 9.1 4.6 148 7 156 305 9.1 0 9.2 8.9 08/27/2005 04:00:00 8.3 1 10.3 4.9 8.1 0.9 10.3 5.7 148 8 150 305 9.1 0 9.2 8.9 08/27/2005 04:10:00 8.6 0.9 11.1 6.5 8.3 0.9 10.3 6.1 148 6 157 305 9 0 9.2 8.9 08/27/2005 04:20:00 8.8 0.9 11.1 6.5 8.6 0.8 11.1 6.5 147 6 155 305 9 0 9.2 8.9 08/27/2005 04:30:00 8.8 0.9 11.1 6.1 8.6 0.8 11.1 6.8 147 7 154 305 9.1 0 9.2 8.9 08/27/2005 04:40:00 8.3 1.3 11.1 4.6 8.5 1 10.7 6.1 156 8 154 305 9.2 0 9.2 9.2 08/27/2005 04:50:00 8.8 1 10.7 5.3 8.5 0.9 10.3 5.3 154 5 157 305 9.2 0 9.2 9.2 08/27/2005 05:00:00 7.1 1.2 9.9 3.4 6.9 1 9.5 4.6 153 7 152 305 9.2 0 9.2 9.2 08/27/2005 05:10:00 7.7 0.9 9.5 4.9 7.6 0.8 9.9 5.7 150 7 150 305 9.2 0 9.2 9.2 08/27/2005 05:20:00 7.4 0.8 9.5 5.7 7.2 0.8 9.5 4.9 147 8 155 305 9.1 0 9.2 9.2 08/27/2005 05:30:00 6.7 0.9 9.1 4.6 6.5 0.8 8.4 4.6 147 8 153 305 9.1 0 9.2 9.2 08/27/2005 05:40:00 5.3 0.8 7.2 3.4 5.4 0.7 7.6 3.8 142 14 136 305 9.1 0 9.2 9.2 08/27/2005 05:50:00 6 1.1 8.4 3.4 5.9 1 8.4 3.4 138 11 129 305 9.1 0 9.2 9.2 08/27/2005 06:00:00 7.2 0.7 8.8 4.9 6.9 0.8 8.8 4.9 135 6 136 305 9.1 0 9.2 9.2 08/27/2005 06:10:00 6.7 1 8.8 3.8 6.5 1 8.8 4.2 137 9 141 305 9.1 0 9.2 8.9 08/27/2005 06:20:00 5.5 1.2 8.8 2.6 5.4 1.1 8 2.6 132 15 133 305 9.1 0 9.2 8.9 08/27/2005 06:30:00 5 1.3 8.8 1.9 5 1.2 8.4 2.6 133 17 141 305 9 0 9.2 8.9 08/27/2005 06:40:00 5.8 1.8 10.7 1.5 5.6 1.7 9.5 1.5 134 18 137 305 9 0 9.2 8.9 08/27/2005 06:50:00 4 1.9 9.1 0.4 4 1.7 8.8 0.4 122 33 127 305 9 0 9.2 8.9 08/27/2005 07:00:00 3.6 1.9 9.5 0.4 3.6 1.7 8.8 0.4 114 30 92 305 8.9 0 9.2 8.9 08/27/2005 07:10:00 3.3 1.9 8.8 0.4 3.5 1.7 9.9 0.7 100 41 84 305 8.9 0 8.9 8.9 08/27/2005 07:20:00 6 1.8 12.6 2.3 5.8 1.7 11.5 2.3 121 24 158 305 8.8 0 8.9 8.7 08/27/2005 07:30:00 7.6 2.3 13.3 3 7.7 2.1 12.6 3.4 128 20 136 305 8.8 0 8.9 8.7 08/27/2005 07:40:00 9 1.7 12.6 4.2 8.8 1.6 13.3 5.3 138 13 149 305 8.7 0 8.9 8.4 08/27/2005 07:50:00 10.2 1.5 14.9 6.8 10 1.6 13.3 6.1 137 10 136 305 8.6 0 8.7 8.4 08/27/2005 08:00:00 9.7 1.8 13.7 4.6 9.6 1.7 13.3 4.9 138 13 138 305 8.4 0 8.7 8.2 08/27/2005 08:10:00 10.1 1.9 14.5 4.6 10 1.7 13.7 6.1 138 12 140 305 8.2 0 8.4 8.2 08/27/2005 08:20:00 7.2 2.2 13.7 3 7 2 13 3.4 121 24 150 305 8.3 0 8.4 8.2 08/27/2005 08:30:00 6.2 2 11.8 1.5 6.1 1.9 11.5 2.6 111 28 88 305 8.4 0 8.4 8.2 08/27/2005 08:40:00 5.6 1.6 11.1 0.7 5.6 1.7 9.5 0.4 115 33 88 305 8.3 0 8.4 8.2 08/27/2005 08:50:00 4.2 1.8 9.1 0.7 4.1 1.7 9.9 0.4 102 41 102 305 8.4 0 8.4 8.2 08/27/2005 09:00:00 4.7 1.7 11.8 1.1 4.6 1.7 11.5 1.1 102 47 106 305 8.4 0 8.4 8.2 08/27/2005 09:10:00 5.7 2.5 14.5 1.1 5.5 2.4 14.9 1.1 114 36 136 305 8.4 0 8.4 8.2 08/27/2005 09:20:00 4.9 2.5 13 0.4 4.7 2.3 11.5 0.7 108 58 136 305 8.4 0 8.4 8.2 08/27/2005 09:30:00 6.5 2.2 13.3 1.5 6.5 2.2 12.2 1.9 119 35 146 305 8.4 0 8.4 8.4 08/27/2005 09:40:00 4.2 2.3 11.1 0.4 4.3 2.3 11.8 0.4 110 56 131 305 8.5 0 8.7 8.4 08/27/2005 09:50:00 4.1 2.3 11.8 0.4 4.1 2.1 9.9 0.4 113 56 112 305 8.6 0 8.7 8.4 08/27/2005 10:00:00 5.1 2.7 13.3 0.4 5.1 2.4 12.2 0.4 117 41 109 305 8.6 0 8.7 8.4 08/27/2005 10:10:00 6.1 2.3 11.5 1.9 6 2.1 11.5 1.5 84 39 42 305 8.6 0 8.7 8.4 08/27/2005 10:20:00 11.8 3.8 22.6 3 11.8 3.8 24 3.4 61 21 70 305 8.6 0 8.7 8.4 08/27/2005 10:30:00 12.3 6.4 30.2 1.1 12.1 6.4 27.1 1.9 90 35 67 305 8.6 0 8.7 8.4 08/27/2005 10:40:00 7.3 3.2 17.2 0.7 7.3 3.2 20.6 0.7 108 43 97 305 8.6 0 8.9 8.4 08/27/2005 10:50:00 8 2.8 18.3 3 8 2.8 18.7 1.5 124 27 142 305 8.8 0 8.9 8.7 08/27/2005 11:00:00 9.8 2.7 17.2 3.8 9.8 2.5 17.6 4.9 132 19 124 305 8.9 0 9.2 8.9 08/27/2005 11:10:00 10.3 2.8 18.7 3.4 10.1 2.7 18.3 3 130 22 135 305 9.1 0 9.2 8.9 08/27/2005 11:20:00 9.9 2.6 16.1 4.6 9.7 2.6 16.1 4.6 131 17 138 305 9.1 0 9.2 8.9 08/27/2005 11:30:00 10.5 2.6 19.5 4.2 10.4 2.5 17.9 4.2 132 19 113 305 9.1 0 9.2 9.2 08/27/2005 11:40:00 10.6 2.6 17.2 3 10.4 2.7 19.1 3.4 132 19 140 305 9.2 0 9.5 9.2 08/27/2005 11:50:00 11.4 3.2 19.1 4.9 11.2 3.1 18.7 4.6 133 18 119 305 9.4 0 9.7 9.2 08/27/2005 12:00:00 10.8 2.7 17.6 4.2 10.6 2.8 17.9 3.8 135 17 146 305 9.5 0 9.7 9.5 08/27/2005 12:10:00 12.2 2.7 17.6 6.8 12.1 2.5 18.3 6.8 136 16 144 305 9.5 0 9.7 9.5 08/27/2005 12:20:00 14.6 2.5 21.4 6.5 14.6 2.3 21.4 8.4 137 12 144 305 9.7 0 10 9.5 08/27/2005 12:30:00 15.6 2.3 22.6 8.4 15.3 2.2 21.4 8.4 138 11 154 305 9.7 0 10 9.7 08/27/2005 12:40:00 14.2 2.2 19.9 8 14 2.1 19.1 8 140 12 135 305 9.7 0 9.7 9.7 08/27/2005 12:50:00 15.2 2.3 20.6 8 14.9 2.3 20.6 9.1 137 10 132 305 9.7 0 9.7 9.7 08/27/2005 13:00:00 15 2.1 20.6 9.5 14.8 1.9 21 9.9 138 9 151 305 9.7 0 10 9.7 08/27/2005 13:10:00 14.3 2.7 20.2 8.4 13.9 2.6 19.5 8 137 12 138 305 9.8 0 10 9.7 08/27/2005 13:20:00 14 2.1 19.5 8.8 13.7 2 19.1 8.4 138 11 130 305 9.7 0 10 9.7 08/27/2005 13:30:00 14.6 2.6 20.2 6.8 14.1 2.3 18.7 8.8 138 11 143 305 9.8 0 10 9.7 08/27/2005 13:40:00 15 2.4 21.4 9.9 14.8 2.2 20.6 8.8 137 11 110 305 9.9 0 10 9.7 08/27/2005 13:50:00 14.3 2.6 20.6 8 14.1 2.5 21 7.2 141 10 144 305 9.9 0 10 9.7 08/27/2005 14:00:00 14.3 2 20.2 9.5 14.1 2.1 19.9 9.5 142 11 125 305 9.9 0 10 9.7 08/27/2005 14:10:00 13.8 2 19.1 8.8 13.6 1.9 19.1 6.8 144 10 144 305 9.9 0 10 9.7 08/27/2005 14:20:00 14 1.7 18.7 9.5 13.6 1.6 19.1 9.9 148 9 145 305 9.9 0 10 9.7 08/27/2005 14:30:00 13.8 1.9 18.3 8.8 13.6 1.7 17.9 9.5 149 9 144 305 9.8 0 10 9.7 08/27/2005 14:40:00 13.8 2 17.9 8 13.5 1.7 17.6 8 150 7 147 305 9.7 0 10 9.7 08/27/2005 14:50:00 11 2.2 15.6 6.1 11.7 1.7 17.2 7.2 156 12 138 305 9.9 0 10.2 9.7 08/27/2005 15:00:00 10.4 1.7 15.6 6.8 10.9 1.3 15.3 7.6 156 10 163 305 10 0 10.2 10 08/27/2005 15:10:00 10.2 1.5 14.9 5.3 10.5 1.2 14.1 7.2 156 8 156 305 10.1 0 10.2 10 08/27/2005 15:20:00 9.6 1.3 12.6 5.7 9.9 1.2 13.7 6.8 154 8 147 305 10.1 0 10.2 10 08/27/2005 15:30:00 9.4 1.3 12.6 5.7 10.1 1.1 12.6 7.6 158 6 151 305 10.2 0 10.2 10.2 08/27/2005 15:40:00 8.4 1.4 12.6 4.6 10.4 1 12.6 7.6 164 6 161 305 10.4 0 10.5 10.2 08/27/2005 15:50:00 7.4 1 10.3 4.9 10.6 1 13 8 170 6 180 305 10.7 0 10.8 10.5 08/27/2005 16:00:00 7.1 1.4 11.5 4.2 9.8 1 13 6.8 172 8 184 305 10.9 0 11 10.8 08/27/2005 16:10:00 8.2 1.9 11.8 3.8 8.8 1.4 12.2 4.9 186 12 189 305 11 0 11.3 10.8 08/27/2005 16:20:00 10.6 0.8 13 8.4 10.2 0.9 12.2 7.2 196 4 195 305 10.8 0 11 10.5 08/27/2005 16:30:00 10.1 0.9 12.6 7.6 9.6 1 12.2 6.5 195 5 194 305 11.2 0 11.3 10.8 08/27/2005 16:40:00 10.9 0.8 13 8.8 10.5 0.8 12.6 8 198 4 201 305 10.8 0.2 11.3 10.5 08/27/2005 16:50:00 10.5 0.8 12.6 8.4 10.1 0.9 12.2 6.8 194 5 193 305 10.7 0 11 10.5 08/27/2005 17:00:00 10.6 1.1 13.3 7.2 10.2 1.2 13.3 6.8 196 4 196 305 11.4 0.2 11.8 10.8 08/27/2005 17:10:00 10.8 0.9 12.6 8 10.5 1 12.2 7.6 197 5 197 305 11.5 0 11.6 11.3 08/27/2005 17:20:00 10.5 0.9 12.6 8 10.1 1 12.6 7.2 195 4 197 305 11.4 0 11.3 11.3 08/27/2005 17:30:00 10.2 1 12.6 7.2 10.2 1 12.2 6.8 190 6 193 305 11.6 0 11.8 11.3 08/27/2005 17:40:00 11.3 1.4 14.1 6.8 11.5 1.5 14.5 6.1 189 5 191 305 11.6 0.1 11.8 11.3 08/27/2005 17:50:00 11.3 1.1 13.3 8 11.5 1.2 13.7 8.4 187 5 196 305 11.4 0 11.6 11.3 08/27/2005 18:00:00 11.9 1.1 13.7 8 12 1.1 14.1 8.8 189 4 187 305 11.4 0 11.6 11 08/27/2005 18:10:00 12 1.5 14.9 6.8 12.1 1.3 14.9 8.8 189 5 192 305 11.2 0 11.3 11 08/27/2005 18:20:00 12.4 1.1 14.9 9.1 12.2 1.5 16.1 8.4 190 4 188 305 10.9 0 11.3 10.8 08/27/2005 18:30:00 10 1.8 13.3 5.7 11.2 1.1 13.7 8.4 183 6 187 305 11 0 11 10.8 08/27/2005 18:40:00 9.1 1.6 13 4.9 11.1 1.2 14.9 7.6 178 6 187 305 10.9 0 11 10.5 08/27/2005 18:50:00 9.3 1.5 13 4.9 11.3 1.1 14.1 8.8 180 5 186 305 10.6 0 10.8 10.5 08/27/2005 19:00:00 7.7 1.8 11.8 3.4 9.3 1.5 13 6.5 179 8 176 305 10.5 0 10.8 10.5 08/27/2005 19:10:00 6.6 1.1 10.7 3.8 8.8 1 11.1 6.1 169 7 161 305 10.4 0 10.5 10.2 08/27/2005 19:20:00 6.5 1.3 11.1 3.8 8.7 1.2 13 6.1 170 8 153 305 10.4 0 10.5 10.2 08/27/2005 19:30:00 7.5 1.3 11.5 4.2 10.4 1.3 14.1 7.2 169 7 169 305 10.2 0 10.5 10 08/27/2005 19:40:00 7.7 1 11.5 5.7 10.6 0.9 13 8.4 167 5 159 305 10 0 10.2 10 08/27/2005 19:50:00 7.5 1.1 11.5 4.9 10.1 1 13 6.8 168 6 161 305 10.1 0 10.2 10 08/27/2005 20:00:00 8.1 1.2 11.1 4.9 10.9 1.2 14.1 7.2 168 6 163 305 10.1 0 10.2 10 08/27/2005 20:10:00 8.4 1.5 13 5.7 10.9 1 13.3 8 166 6 160 305 10.1 0 10.2 10 08/27/2005 20:20:00 8.4 1.4 12.2 4.6 11.2 1.3 15.3 7.2 167 6 176 305 10.2 0 10.2 10.2 08/27/2005 20:30:00 8.4 1.2 13 6.1 11.3 1 13.7 8.4 168 6 159 305 10.2 0 10.2 10.2 08/27/2005 20:40:00 8.7 1.2 14.5 5.3 12 1.3 15.3 8.8 169 6 156 305 10.2 0 10.2 10.2 08/27/2005 20:50:00 9.1 1.1 12.2 6.5 12.9 1.1 15.6 10.3 170 5 161 305 10.3 0 10.2 10.2 08/27/2005 21:00:00 9 1 12.6 6.5 12.1 1.1 14.9 9.1 169 5 160 305 10.2 0 10.2 10.2 08/27/2005 21:10:00 8.6 1.1 11.8 5.7 11.8 1.2 14.5 8.4 169 6 159 305 10.2 0 10.2 10.2 08/27/2005 21:20:00 8.9 1.2 13 6.1 11.7 1.1 15.3 8.8 167 7 159 305 10.2 0 10.2 10.2 08/27/2005 21:30:00 8.6 1.3 13.7 5.7 11.6 1.2 14.9 7.6 168 6 159 305 10.3 0 10.5 10.2 08/27/2005 21:40:00 8.5 1.2 13 6.1 11.9 1.1 14.1 8.8 169 6 157 305 10.3 0 10.5 10.2 08/27/2005 21:50:00 8.8 1.3 13 5.3 12.1 1.1 15.3 9.1 169 6 155 305 10.3 0 10.5 10.2 08/27/2005 22:00:00 8.5 1.2 13 5.3 11.8 1.1 15.3 8.8 170 6 159 305 10.3 0 10.5 10.2 08/27/2005 22:10:00 7.9 1.5 12.6 4.9 10.6 1.2 13.3 7.2 175 7 175 305 10.4 0 10.5 10.2 08/27/2005 22:20:00 7.8 1.2 11.8 5.3 11 1.2 14.1 8 172 7 175 305 10.4 0 10.5 10.2 08/27/2005 22:30:00 8.7 1.2 14.1 6.1 12.4 1.3 16.1 9.1 169 6 160 305 10.4 0 10.5 10.2 08/27/2005 22:40:00 8.8 1 13 6.5 12.8 1 15.6 10.3 170 5 172 305 10.4 0 10.5 10.2 08/27/2005 22:50:00 8.9 1.3 13.3 5.3 12.2 1.3 16.1 8 171 7 159 305 10.3 0 10.5 10.2 08/27/2005 23:00:00 9.2 1.2 13.3 6.5 12.4 1.3 15.3 8.8 171 6 165 305 10.3 0 10.5 10.2 08/27/2005 23:10:00 9.2 1.3 14.9 6.5 12.6 1.2 16.1 9.9 170 6 156 305 10.3 0 10.2 10.2 08/27/2005 23:20:00 9.2 1.3 13 6.5 12.5 1.3 16.4 8.8 170 7 163 305 10.3 0 10.2 10.2 08/27/2005 23:30:00 9.4 1.4 13.3 6.1 12.3 1.5 15.6 8.8 171 7 163 305 10.2 0 10.2 10.2 08/27/2005 23:40:00 9.3 1.5 14.9 5.7 12.4 1.4 16.8 8.8 172 7 161 305 10.2 0 10.2 10.2 08/27/2005 23:50:00 9.9 1.4 15.3 5.7 13.1 1.4 18.3 9.5 171 7 167 305 10.1 0 10.2 10 08/28/2005 00:00:00 9.6 1.3 15.6 6.1 13 1.5 17.6 9.5 171 7 170 305 10.2 0 10.5 10 08/28/2005 00:10:00 9.6 1.2 14.1 6.5 13.7 1.1 16.1 10.7 170 6 164 305 10.2 0 10.2 10.2 08/28/2005 00:20:00 9.9 1.2 14.1 7.6 13.9 1.3 17.9 10.3 170 5 165 305 10.2 0 10.2 10 08/28/2005 00:30:00 9.9 1.2 14.5 7.6 13.9 1.2 17.2 10.7 169 6 160 305 10.2 0 10.2 10.2 08/28/2005 00:40:00 9.7 1.2 13.7 6.5 13.7 1.3 17.2 9.5 169 5 166 305 10.2 0 10.2 10 08/28/2005 00:50:00 9.7 1.2 13 7.2 13.2 1.4 16.8 9.5 168 5 162 305 10.1 0 10.2 10 08/28/2005 01:00:00 9.8 1 13.3 7.6 13.5 1.1 16.1 10.3 169 6 156 305 10.2 0 10.2 10 08/28/2005 01:10:00 9.6 1.1 13 6.5 13.5 1.3 16.8 9.5 169 5 166 305 10.2 0 10.2 10.2 08/28/2005 01:20:00 9.8 1.1 13.3 6.8 13.6 1.4 17.2 9.5 168 6 171 305 10.1 0 10.2 10 08/28/2005 01:30:00 9.5 1.2 14.1 6.5 13.5 1.2 16.1 10.3 169 5 159 305 10.1 0 10.2 10 08/28/2005 01:40:00 9.6 1.2 13.7 6.8 13.2 1.3 16.1 9.9 168 6 168 305 10 0 10.2 10 08/28/2005 01:50:00 9.4 1.3 13.3 6.1 12.9 1.3 16.1 9.1 168 6 158 305 10 0 10 10 08/28/2005 02:00:00 9.2 1.2 12.6 6.1 12.5 1.5 16.8 8.8 168 6 159 305 10 0 10.2 10 08/28/2005 02:10:00 9.3 1.2 13.3 6.5 12.8 1.4 16.4 8.8 168 6 172 305 10 0 10.2 10 08/28/2005 02:20:00 9.2 1.3 13.3 6.5 13 1.2 16.1 9.5 168 5 161 305 10 0 10 10 08/28/2005 02:30:00 9.3 1.2 13.7 6.5 13 1.2 15.6 9.9 168 5 160 305 10 0 10 10 08/28/2005 02:40:00 9.3 1.2 13.3 6.5 13.5 1.2 16.8 9.9 170 5 176 305 10 0 10.2 10 08/28/2005 02:50:00 8.8 1.1 12.6 6.5 12.6 1.2 15.6 9.5 170 6 171 305 10.1 0 10.2 10 08/28/2005 03:00:00 8.6 1 11.5 5.7 12.6 1.2 15.6 8.4 170 5 162 305 10 0 10.2 10 08/28/2005 03:10:00 8.6 1.1 13.7 6.1 12.7 1.2 15.6 9.1 169 5 161 305 10.1 0 10.2 10 08/28/2005 03:20:00 8.6 1.1 12.6 6.5 12.5 1.1 15.3 9.9 169 5 165 305 10.1 0 10.2 10 08/28/2005 03:30:00 8.4 1.3 12.6 4.9 11.6 1.3 15.6 6.8 168 6 169 305 10 0 10.2 10 08/28/2005 03:40:00 8.1 1.1 11.8 5.7 11.3 1 14.1 8 169 6 165 305 10 0 10.2 10 08/28/2005 03:50:00 7.8 1.2 11.8 5.3 10.8 1.1 13.7 8 168 6 165 305 9.9 0 10 9.7 08/28/2005 04:00:00 8.2 1.4 12.6 5.3 10.7 1.1 13.3 7.6 165 6 160 305 9.9 0 10 10 08/28/2005 04:10:00 7.6 1.4 12.6 4.9 9.8 1 13 6.8 165 6 165 305 9.9 0 10 9.7 08/28/2005 04:20:00 7.5 1.1 11.1 4.9 10.2 1 13 7.6 168 6 163 305 9.8 0 10 9.7 08/28/2005 04:30:00 7.9 1.2 11.5 4.9 10.6 1 12.6 7.2 167 6 162 305 9.9 0 10 9.7 08/28/2005 04:40:00 7.7 1.2 10.7 4.9 10.1 1.1 12.6 6.8 166 6 163 305 9.9 0 10 9.7 08/28/2005 04:50:00 7.6 1.3 11.5 4.9 10 1 12.6 7.2 166 6 160 305 9.8 0 10 9.7 08/28/2005 05:00:00 7 1.2 11.1 4.6 9.7 1 12.2 6.8 167 5 171 305 9.8 0 10 9.7 08/28/2005 05:10:00 6.8 1.1 10.7 4.2 9.6 1 12.6 7.2 168 5 165 305 9.9 0 10 9.7 08/28/2005 05:20:00 6.6 1 9.5 4.2 9.8 1.1 12.6 6.8 171 6 165 305 9.9 0 10 9.7 08/28/2005 05:30:00 6 1 9.5 3.8 8.7 1 11.1 6.1 171 7 160 305 9.9 0 10 9.7 08/28/2005 05:40:00 6.4 1.3 9.9 3.8 8.9 0.9 11.5 6.8 174 8 180 305 9.9 0 10 9.7 08/28/2005 05:50:00 6.1 1.2 11.1 3.8 8.2 1 11.1 5.7 176 7 188 305 9.8 0 10 9.7 08/28/2005 06:00:00 6.1 1.3 9.5 3 8 1 10.3 5.3 176 8 181 305 9.7 0 9.7 9.7 08/28/2005 06:10:00 6 1.2 9.5 3.4 7.9 0.9 9.9 5.7 178 6 188 305 9.7 0 9.7 9.7 08/28/2005 06:20:00 6.2 1.2 8.8 3.4 8 0.9 10.3 5.7 179 6 176 305 9.7 0 9.7 9.7 08/28/2005 06:30:00 6.3 1 8.8 4.2 7.6 0.7 9.5 6.1 181 5 181 305 9.7 0 9.7 9.5 08/28/2005 06:40:00 6.2 1 8.8 3.4 7.5 0.7 9.1 5.7 181 5 183 305 9.7 0 9.7 9.5 08/28/2005 06:50:00 6.2 0.9 8 3 7.3 0.7 9.1 4.9 182 5 188 305 9.7 0 9.7 9.5 08/28/2005 07:00:00 6.1 0.9 8 3.8 7 0.7 8.4 4.9 183 5 188 305 9.7 0 9.7 9.5 08/28/2005 07:10:00 6 0.6 7.6 3.4 6.4 0.7 8.4 4.9 186 4 186 305 9.6 0 9.7 9.5 08/28/2005 07:20:00 6.3 0.8 8.4 4.6 6.3 0.9 8.8 4.2 192 5 193 305 9.7 0 9.7 9.5 08/28/2005 07:30:00 7.1 0.6 8.4 4.9 7.1 0.8 8.8 4.9 193 5 202 305 9.5 0 9.7 9.5 08/28/2005 07:40:00 7.2 0.6 8.4 4.9 7 0.6 8.8 4.6 195 5 199 305 9.3 0 9.5 9.2 08/28/2005 07:50:00 7 0.5 8.4 4.9 6.8 0.6 8 5.3 196 5 197 305 9.2 0 9.5 9.2 08/28/2005 08:00:00 6.9 0.4 8 5.7 6.7 0.5 8 4.9 197 4 199 305 9.2 0 9.5 9.2 08/28/2005 08:10:00 6.5 0.5 7.6 4.9 6.4 0.5 7.6 4.6 196 4 201 305 9.1 0 9.2 9.2 08/28/2005 08:20:00 6.2 0.4 7.2 4.9 6.1 0.5 7.2 4.6 198 4 202 305 9 0 9.2 8.9 08/28/2005 08:30:00 5.8 0.5 6.8 4.6 5.5 0.6 6.8 4.2 197 5 196 305 8.9 0 9.2 8.9 08/28/2005 08:40:00 5.4 0.4 6.8 4.6 5.3 0.5 6.5 3.8 197 5 198 305 8.9 0 9.2 8.9 08/28/2005 08:50:00 5.3 0.3 6.1 4.6 5.3 0.4 6.1 3.8 196 4 201 305 9 0 9.2 8.9 08/28/2005 09:00:00 4.9 0.3 5.7 4.2 5 0.4 6.1 3.8 196 4 194 305 9.1 0 9.2 8.9 08/28/2005 09:10:00 4.9 0.3 5.3 4.2 4.9 0.3 5.7 4.2 198 4 197 305 9.1 0 9.2 8.9 08/28/2005 09:20:00 4.5 0.3 4.9 3.8 4.6 0.3 5.3 3.4 201 4 200 305 9.1 0 9.2 8.9 08/28/2005 09:30:00 4.2 0.2 4.9 3.8 4.3 0.3 4.9 3 200 3 205 305 9.2 0 9.2 9.2 08/28/2005 09:40:00 4 0.2 4.6 3.4 4.1 0.3 4.6 3 196 4 199 305 9.2 0 9.2 9.2 08/28/2005 09:50:00 3.7 0.3 4.2 3 3.8 0.4 4.9 2.6 196 4 201 305 9.2 0 9.5 9.2 08/28/2005 10:00:00 3.6 0.2 4.2 3 3.8 0.3 4.6 3 200 4 198 305 9.2 0 9.5 9.2 08/28/2005 10:10:00 3.1 0.2 3.8 2.3 3.3 0.3 3.8 2.6 210 6 207 305 9.2 0 9.5 9.2 08/28/2005 10:20:00 2.8 0.3 3.4 1.9 2.9 0.3 3.8 2.3 221 7 217 305 9.2 0 9.5 9.2 08/28/2005 10:30:00 2.4 0.5 3.8 1.1 2.5 0.4 3.4 1.5 228 8 227 305 9.3 0 9.5 9.2 08/28/2005 10:40:00 1.9 0.5 3 0.4 2.1 0.3 3 1.5 230 9 235 305 9.4 0 9.5 9.2 08/28/2005 10:50:00 1.9 0.4 3 0.7 2 0.3 3 1.1 231 8 236 305 9.5 0 9.7 9.5 08/28/2005 11:00:00 2.2 0.5 3.4 1.1 2.2 0.4 3.4 1.5 234 8 239 305 9.6 0 9.7 9.5 08/28/2005 11:10:00 2.6 0.5 3.4 1.1 2.4 0.4 3.4 1.5 238 7 234 305 9.6 0 9.7 9.5 08/28/2005 11:20:00 2.5 0.4 3.4 1.5 2.5 0.4 3.8 1.5 243 7 237 305 9.5 0 9.7 9.5 08/28/2005 11:30:00 2.3 0.4 3 1.1 2.3 0.3 3.4 1.5 241 7 249 305 9.5 0 9.7 9.5 08/28/2005 11:40:00 2.5 0.4 3.4 1.5 2.5 0.4 3 1.5 238 5 241 305 9.5 0 9.7 9.5 08/28/2005 11:50:00 2.4 0.4 3 1.5 2.5 0.3 3 1.9 233 5 234 305 9.5 0 9.7 9.5 08/28/2005 12:00:00 2.5 0.4 3 1.5 2.6 0.3 3.4 1.9 238 5 238 305 9.5 0 9.7 9.5 08/28/2005 12:10:00 2.4 0.5 3.4 1.1 2.5 0.4 3.4 1.9 238 7 237 305 9.5 0 9.7 9.5 08/28/2005 12:20:00 2.8 0.4 3.8 1.5 2.8 0.4 3.4 1.9 237 7 237 305 9.5 0 9.7 9.5 08/28/2005 12:30:00 3.1 0.4 4.2 1.9 2.9 0.4 3.8 2.3 240 8 241 305 9.3 0 9.5 9.2 08/28/2005 12:40:00 3.2 0.5 4.2 1.5 3 0.5 4.2 1.5 247 8 243 305 9.3 0 9.5 9.2 08/28/2005 12:50:00 3.5 0.5 4.6 1.9 3.3 0.5 4.2 2.3 246 8 251 305 9.4 0 9.7 9.2 08/28/2005 13:00:00 3.7 0.5 4.6 2.6 3.6 0.5 4.9 2.3 246 7 241 305 9.4 0 9.7 9.2 08/28/2005 13:10:00 3.5 0.4 4.6 2.3 3.3 0.5 4.6 2.3 247 8 251 305 9.4 0 9.7 9.2 08/28/2005 13:20:00 3.5 0.5 4.6 2.3 3.3 0.5 4.6 1.9 250 8 249 305 9.3 0 9.5 9.2 08/28/2005 13:30:00 3.3 0.4 4.2 1.9 3 0.5 4.2 1.9 254 8 259 305 9.2 0 9.2 9.2 08/28/2005 13:40:00 2.7 0.4 3.4 1.5 2.3 0.5 3.4 1.1 261 8 256 305 9.1 0 9.2 8.9 08/28/2005 13:50:00 2.8 0.6 3.8 1.1 2.7 0.7 4.2 1.1 284 14 278 305 8.9 0 9.2 8.7 08/28/2005 14:00:00 3.1 0.3 3.8 2.3 3.2 0.4 3.8 2.3 307 17 294 305 8.4 0 8.7 8.2 08/28/2005 14:10:00 3 0.4 3.8 1.9 2.9 0.4 3.8 1.9 312 13 309 305 8.1 0 8.4 7.9 08/28/2005 14:20:00 2.5 0.4 3.4 1.5 2.5 0.3 3.4 1.5 315 11 325 305 8 0 8.2 7.9 08/28/2005 14:30:00 2.7 0.4 3.4 1.5 2.5 0.4 3.4 1.5 320 8 326 305 8 0 8.2 7.9 08/28/2005 14:40:00 3.3 0.5 4.6 2.3 3.1 0.6 4.6 1.5 323 6 323 305 8 0 8.2 7.7 08/28/2005 14:50:00 4.1 0.5 4.9 2.6 4 0.5 5.3 3 323 5 329 305 7.7 0.1 8.2 7.7 08/28/2005 15:00:00 4.6 0.5 5.7 3 4.5 0.5 5.7 3.4 329 4 333 305 7.6 0 7.7 7.7 08/28/2005 15:10:00 5.3 0.4 6.5 3.8 5.2 0.5 6.5 3.4 334 4 340 305 7.6 0 7.7 7.4 08/28/2005 15:20:00 5.3 0.5 6.5 3.8 5.3 0.6 6.5 3.8 340 5 346 305 7.5 0 7.7 7.4 08/28/2005 15:30:00 6 0.5 7.2 4.6 6 0.6 7.6 4.2 345 4 344 305 7.5 0 7.7 7.4 08/28/2005 15:40:00 6.8 0.6 8.4 5.3 6.8 0.6 8 5.3 345 4 347 305 7.5 0 7.7 7.4 08/28/2005 15:50:00 7.1 0.5 8.4 5.7 7.1 0.5 8.4 5.7 345 3 347 305 7.3 0 7.7 7.2 08/28/2005 16:00:00 7.2 0.5 8.4 5.3 7.2 0.5 8.4 5.7 342 4 348 305 7.4 0 7.7 7.4 08/28/2005 16:10:00 7.5 0.6 9.1 6.1 7.5 0.6 9.5 6.1 339 3 338 305 7.2 0 7.4 7.2 08/28/2005 16:20:00 7.8 0.5 9.1 6.5 7.9 0.6 9.1 5.7 339 3 341 305 7 0 7.2 6.9 08/28/2005 16:30:00 8.2 0.5 9.5 6.5 8.1 0.6 9.5 6.1 339 3 337 305 6.9 0 7.2 6.9 08/28/2005 16:40:00 8.6 0.5 9.5 6.8 8.6 0.6 9.9 6.8 336 3 333 305 7 0 7.2 6.9 08/28/2005 16:50:00 9.3 0.5 10.3 8 9.4 0.6 10.7 7.6 336 3 333 305 6.8 0 7.2 6.7 08/28/2005 17:00:00 9.4 0.7 10.7 7.6 9.5 0.8 11.1 6.8 337 3 342 305 6.8 0 7.2 6.7 08/28/2005 17:10:00 10 0.6 11.8 8.4 10 0.8 11.5 7.6 334 3 334 305 6.7 0 6.9 6.7 08/28/2005 17:20:00 10.4 0.7 11.8 8.8 10.4 0.8 11.8 8 337 3 336 305 6.5 0 6.7 6.4 08/28/2005 17:30:00 10.4 0.6 11.8 8.4 10.5 0.7 12.2 7.6 340 3 340 305 6.5 0 6.9 6.4 08/28/2005 17:40:00 10.5 0.6 11.8 8.4 10.6 0.7 12.2 8.4 345 3 345 305 6.7 0 6.9 6.4 08/28/2005 17:50:00 10.3 0.6 11.8 8.8 10.2 0.7 11.8 8.4 346 3 347 305 6.7 0 6.9 6.7 08/28/2005 18:00:00 9.9 0.8 11.8 8 10.1 1 12.2 7.6 344 4 344 305 6.8 0 6.9 6.7 08/28/2005 18:10:00 10.1 0.8 12.2 8.4 10.1 0.9 12.6 8 345 4 346 305 6.8 0 7.2 6.9 08/28/2005 18:20:00 10.4 0.8 12.6 8.8 10.4 1 12.6 8 344 3 349 305 6.8 0 7.2 6.7 08/28/2005 18:30:00 10.3 0.7 12.2 8.4 10.4 0.8 12.6 8 341 3 339 305 6.9 0 7.2 6.9 08/28/2005 18:40:00 10.5 0.7 11.8 8 10.5 0.8 12.6 8.4 344 3 344 305 6.8 0 7.2 6.9 08/28/2005 18:50:00 10.9 0.8 12.6 9.1 10.9 0.8 13 9.1 342 3 342 305 6.9 0 7.2 6.9 08/28/2005 19:00:00 11 0.7 12.2 9.1 11 0.8 12.6 9.1 336 3 340 305 7 0 7.2 6.9 08/28/2005 19:10:00 10.7 0.9 12.2 8.8 10.7 0.9 12.6 8 335 4 340 305 6.8 0 7.2 6.9 08/28/2005 19:20:00 10.8 0.8 13 8.4 10.8 0.9 13.3 8 340 4 344 305 6.8 0 6.9 6.7 08/28/2005 19:30:00 11.5 0.8 13.3 9.5 11.6 1 13.3 8.8 343 3 342 305 7 0 7.2 6.9 08/28/2005 19:40:00 10.6 0.9 12.6 8.8 10.5 1 12.6 8 346 3 350 305 7.1 0 7.4 7.2 08/28/2005 19:50:00 10.6 0.7 12.2 8.8 10.6 0.8 12.6 7.6 345 3 344 305 7.2 0 7.4 7.2 08/28/2005 20:00:00 10 0.7 11.8 8 9.8 0.9 11.8 7.2 346 3 345 305 7.4 0 7.7 7.4 08/28/2005 20:10:00 10.9 0.7 13 9.1 10.9 0.8 13.3 8.8 344 3 346 305 7.5 0 7.7 7.4 08/28/2005 20:20:00 10.8 0.8 12.2 8.8 10.9 0.8 13 8.8 340 3 337 305 7.4 0 7.7 7.2 08/28/2005 20:30:00 11.4 0.8 13 9.1 11.4 0.8 13 8.8 343 4 341 305 7 0 7.4 6.9 08/28/2005 20:40:00 10.3 0.8 12.2 8.4 10.4 0.8 13 8 345 4 345 305 7 0 7.2 6.9 08/28/2005 20:50:00 10.7 0.7 12.2 8.8 10.9 0.8 12.6 8.8 348 4 347 305 7 0 7.2 6.9 08/28/2005 21:00:00 10.8 0.7 12.6 9.1 11 0.8 13 8.8 346 3 352 305 7 0 7.2 6.9 08/28/2005 21:10:00 10.7 0.8 12.6 8.4 10.7 1 13 8 346 3 343 305 7 0 7.2 7.2 08/28/2005 21:20:00 10.9 0.7 13 9.1 11 0.8 13 9.1 349 3 338 305 7 0 7.2 6.9 08/28/2005 21:30:00 10.7 0.7 12.2 9.1 10.9 0.8 12.6 8.4 349 3 350 305 7 0 7.2 6.9 08/28/2005 21:40:00 10.1 0.6 11.5 8.4 10.2 0.7 11.8 7.6 348 3 345 305 6.9 0 7.2 6.9 08/28/2005 21:50:00 9.2 0.7 10.7 6.8 9.3 0.8 11.1 6.8 343 4 348 305 6.9 0 7.2 6.9 08/28/2005 22:00:00 9.7 0.6 11.5 7.6 9.9 0.7 11.1 7.6 343 3 338 305 6.9 0 7.2 6.9 08/28/2005 22:10:00 9.7 0.6 11.1 8 9.8 0.7 11.1 8 347 3 348 305 7 0 7.2 6.9 08/28/2005 22:20:00 9.9 0.7 11.5 8 10.1 0.8 11.8 7.2 345 3 347 305 7 0 7.2 6.9 08/28/2005 22:30:00 9.6 0.5 10.7 8.4 9.7 0.5 11.1 8 345 3 349 305 7 0 7.2 6.9 08/28/2005 22:40:00 9.4 0.6 10.7 7.6 9.4 0.7 11.1 6.8 347 3 345 305 7 0 7.2 7.2 08/28/2005 22:50:00 9.2 0.8 11.1 6.8 9.2 1 11.5 6.5 345 3 347 305 7.1 0 7.2 7.2 08/28/2005 23:00:00 8.9 0.6 9.9 7.2 8.9 0.7 10.7 7.2 345 3 349 305 7.2 0 7.4 7.2 08/28/2005 23:10:00 9 0.6 10.7 7.6 9.1 0.8 11.1 7.2 344 3 339 305 7.5 0 7.7 7.4 08/28/2005 23:20:00 8.8 0.6 10.3 7.2 8.8 0.7 10.7 6.8 342 4 346 305 7.6 0 7.7 7.4 08/28/2005 23:30:00 8.5 0.5 9.9 7.2 8.4 0.6 9.9 6.8 336 3 333 305 7.7 0 7.9 7.7 08/28/2005 23:40:00 8.6 0.5 9.5 7.2 8.5 0.6 9.9 6.8 337 3 336 305 7.9 0 7.9 7.7 08/28/2005 23:50:00 8.3 0.6 9.9 7.2 8.1 0.6 10.3 6.8 334 4 334 305 8 0 8.2 7.9 08/29/2005 00:00:00 8.6 0.6 10.3 7.2 8.5 0.7 10.7 6.8 337 4 339 305 8.2 0 8.7 8.2 08/29/2005 00:10:00 8.9 0.5 9.9 7.6 8.8 0.5 10.3 7.6 341 3 340 305 8.2 0 8.4 8.2 08/29/2005 00:20:00 9 0.6 10.3 7.2 9 0.6 10.3 7.2 342 3 339 305 8.3 0 8.4 8.2 08/29/2005 00:30:00 8.9 0.7 10.7 7.2 8.9 0.7 10.7 7.6 340 4 340 305 8.4 0 8.4 8.2 08/29/2005 00:40:00 9.7 0.7 11.5 7.6 9.8 0.7 11.8 7.6 342 3 341 305 8.4 0 8.4 8.4 08/29/2005 00:50:00 9.8 0.6 11.8 8 9.8 0.6 11.5 8 339 4 334 305 8.4 0 8.4 8.2 08/29/2005 01:00:00 10.2 0.7 11.8 8.4 10.3 0.8 12.2 8 342 3 340 305 8.4 0 8.4 8.2 08/29/2005 01:10:00 10.2 0.6 12.6 8.4 10.2 0.6 12.6 8.8 343 3 346 305 8.4 0 8.4 8.2 08/29/2005 01:20:00 10.1 0.7 11.8 8.4 10.1 0.7 12.2 8.4 344 3 348 305 8.4 0 8.4 8.2 08/29/2005 01:30:00 9.1 0.8 11.1 6.8 9.1 0.9 11.5 6.8 341 4 345 305 8.2 0 8.4 8.2 08/29/2005 01:40:00 8.8 0.5 10.3 7.6 8.7 0.6 10.3 7.2 338 4 339 305 8.3 0 8.4 8.2 08/29/2005 01:50:00 9.4 0.6 11.1 8 9.4 0.6 11.1 8 342 4 336 305 8.4 0 8.4 8.2 08/29/2005 02:00:00 9.6 0.6 11.5 7.6 9.7 0.6 11.5 7.6 341 4 343 305 8.4 0 8.4 8.4 08/29/2005 02:10:00 8.8 0.6 10.3 7.2 8.8 0.6 10.7 7.6 336 4 341 305 8.4 0 8.7 8.4 08/29/2005 02:20:00 8 0.6 9.5 6.5 7.9 0.6 9.5 6.1 333 4 333 305 8.4 0 8.4 8.4 08/29/2005 02:30:00 7.6 0.6 9.5 6.1 7.5 0.6 9.9 6.1 327 5 336 305 8.5 0 8.7 8.4 08/29/2005 02:40:00 7.8 0.7 9.5 6.1 7.7 0.7 9.5 6.1 327 5 327 305 8.5 0 8.7 8.4 08/29/2005 02:50:00 7.6 0.6 9.5 6.1 7.6 0.6 9.5 6.1 328 5 331 305 8.6 0 8.7 8.4 08/29/2005 03:00:00 8.2 0.6 9.5 6.8 8.3 0.7 9.9 5.7 332 5 331 305 8.6 0 8.7 8.4 08/29/2005 03:10:00 8.7 0.8 10.7 6.8 8.7 0.7 11.1 6.8 338 4 338 305 8.6 0 8.7 8.4 08/29/2005 03:20:00 9.1 0.7 11.1 7.2 9.1 0.8 11.1 6.8 337 5 333 305 8.6 0 8.7 8.4 08/29/2005 03:30:00 9.1 0.5 10.7 7.6 9 0.6 10.3 7.2 333 5 338 305 8.6 0 8.9 8.4 08/29/2005 03:40:00 8.8 0.7 10.7 6.5 8.6 0.8 11.1 6.8 326 7 330 305 8.8 0 8.9 8.7 08/29/2005 03:50:00 9.2 0.9 11.1 6.8 9 0.9 11.5 6.8 327 6 327 305 8.9 0 9.2 8.9 08/29/2005 04:00:00 8.9 1 11.5 6.8 8.9 1 11.5 6.8 331 5 333 305 8.8 0 8.9 8.7 08/29/2005 04:10:00 9.2 0.7 11.5 7.6 9.2 0.8 11.5 6.8 331 4 334 305 8.7 0 8.9 8.4 08/29/2005 04:20:00 9.2 0.6 11.1 7.6 9.2 0.7 11.1 6.8 333 4 336 305 8.6 0 8.7 8.4 08/29/2005 04:30:00 9.3 0.7 11.5 7.6 9.3 0.7 11.1 7.2 336 4 333 305 8.6 0 8.7 8.4 08/29/2005 04:40:00 10.1 0.8 12.6 8 10.2 0.8 11.8 7.6 338 4 336 305 8.4 0 8.4 8.2 08/29/2005 04:50:00 10.3 0.9 13.3 8.4 10.5 0.9 13 8.4 339 4 340 305 8.4 0 8.4 8.2 08/29/2005 05:00:00 10.4 0.8 12.6 8.4 10.4 0.8 12.6 8.4 342 4 350 305 8.2 0 8.4 8.2 08/29/2005 05:10:00 10.7 0.7 12.6 8.8 10.9 0.8 13 8.8 341 4 342 305 8.2 0 8.4 8.2 08/29/2005 05:20:00 11.5 0.8 13.7 9.5 11.6 0.8 13.7 9.9 342 4 339 305 8.2 0 8.4 8.2 08/29/2005 05:30:00 11.5 0.8 13.7 9.9 11.6 0.9 14.1 9.5 342 4 343 305 8.2 0 8.4 8.2 08/29/2005 05:40:00 11.9 0.9 14.1 8.8 12 0.9 14.1 9.1 343 4 352 305 8.2 0 8.4 8.2 08/29/2005 05:50:00 12.4 0.9 14.5 9.9 12.5 1 14.5 9.5 341 4 336 305 8.2 0 8.4 8.2 08/29/2005 06:00:00 12 0.9 15.3 9.1 12.1 1 15.6 9.1 340 4 337 305 8.2 0 8.4 8.2 08/29/2005 06:10:00 11.7 0.8 14.1 9.5 11.8 0.9 14.5 9.5 341 4 342 305 8.2 0 8.4 8.2 08/29/2005 06:20:00 11.8 1 13.7 9.1 11.9 1 14.1 9.1 341 4 334 305 8.2 0 8.4 8.2 08/29/2005 06:30:00 12.2 1 14.9 9.9 12.2 1 14.5 9.5 343 4 340 305 8.2 0 8.4 8.2 08/29/2005 06:40:00 12.3 0.9 14.9 10.3 12.5 1 15.3 10.7 344 4 346 305 8.1 0 8.2 8.2 08/29/2005 06:50:00 13 0.9 15.6 11.1 13.2 0.9 15.6 11.1 345 4 341 305 8.1 0 8.2 7.9 08/29/2005 07:00:00 12.7 1 15.3 10.3 12.8 1 15.3 10.3 345 3 348 305 7.9 0 8.2 7.9 08/29/2005 07:10:00 13.3 0.9 15.3 10.7 13.5 1 16.1 10.7 346 4 345 305 7.9 0 7.9 7.9 08/29/2005 07:20:00 13.1 1 15.3 9.9 13.2 1 15.6 9.9 347 4 350 305 7.9 0 7.9 7.9 08/29/2005 07:30:00 13.3 1.1 16.4 10.3 13.3 1.3 16.4 9.9 350 4 352 305 7.9 0 7.9 7.7 08/29/2005 07:40:00 14.2 1 17.2 11.8 14.3 1.2 17.6 10.7 351 4 344 305 7.8 0 7.9 7.7 08/29/2005 07:50:00 14.5 1.1 16.8 11.1 14.7 1.2 17.2 11.5 351 3 347 305 7.9 0 7.9 7.7 08/29/2005 08:00:00 14.2 1.2 17.9 11.5 14.2 1.3 17.2 11.1 351 4 355 305 7.9 0 8.2 7.9 08/29/2005 08:10:00 13.9 1.2 17.2 11.1 13.9 1.3 17.9 10.7 350 4 344 305 7.9 0 7.9 7.9 08/29/2005 08:20:00 13.7 1.1 16.8 10.7 13.7 1.2 16.4 10.7 351 4 351 305 7.9 0 8.2 7.9 08/29/2005 08:30:00 14 1.1 16.4 11.5 14.1 1.1 16.8 10.3 351 4 354 305 8 0 8.2 7.9 08/29/2005 08:40:00 14.1 1 17.2 11.1 14.1 1.1 16.8 10.3 351 4 345 305 8 0 8.2 7.7 08/29/2005 08:50:00 14.7 1.1 17.6 11.5 14.8 1.2 17.2 10.7 351 4 347 305 7.9 0 7.9 7.7 08/29/2005 09:00:00 14.4 1.1 17.2 11.5 14.5 1.1 17.2 11.5 350 4 347 305 7.9 0 7.9 7.4 08/29/2005 09:10:00 14.2 1.1 17.2 11.5 14.3 1.2 17.2 11.1 350 5 344 305 7.8 0 7.9 7.7 08/29/2005 09:20:00 13.8 1.1 16.8 9.5 13.7 1.2 17.6 9.9 351 5 356 305 7.9 0 7.9 7.7 08/29/2005 09:30:00 14.5 1.2 17.9 11.1 14.5 1.3 18.3 10.3 349 4 345 305 8 0 8.2 7.9 08/29/2005 09:40:00 14.7 1.2 18.7 11.5 14.6 1.3 18.3 11.8 350 4 349 305 8 0 8.2 7.9 08/29/2005 09:50:00 15.6 1.2 19.1 12.2 15.6 1.4 19.1 11.5 350 4 343 305 8 0 8.2 7.9 08/29/2005 10:00:00 14.8 1.3 18.7 12.2 14.7 1.4 19.1 11.8 349 4 353 305 8 0 8.2 7.9 08/29/2005 10:10:00 15 1.3 18.7 11.5 15.1 1.2 17.9 11.8 348 4 351 305 7.9 0 7.9 7.7 08/29/2005 10:20:00 14.6 1.1 17.6 11.8 14.7 1.2 18.3 11.5 346 4 351 305 7.9 0 7.9 7.7 08/29/2005 10:30:00 14.3 1.3 17.2 10.3 14.4 1.4 17.6 9.9 347 4 340 305 7.9 0 7.9 7.7 08/29/2005 10:40:00 14.3 1.1 16.8 11.1 14.3 1.1 16.8 10.3 347 5 345 305 7.9 0 7.9 7.7 08/29/2005 10:50:00 13.9 1.2 16.8 11.1 13.9 1.5 17.2 10.3 348 4 346 305 7.9 0 8.2 7.9 08/29/2005 11:00:00 13.8 1.2 16.8 9.9 13.8 1.3 16.8 10.3 348 4 339 305 7.9 0 7.9 7.7 08/29/2005 11:10:00 13.3 1.1 16.1 10.3 13.3 1.2 16.4 9.9 348 4 347 305 7.9 0 7.9 7.7 08/29/2005 11:20:00 13.7 1.1 16.8 10.7 13.7 1.2 16.8 10.3 352 5 355 305 8 0 8.2 7.9 08/29/2005 11:30:00 13.9 1.2 17.2 11.1 14.1 1.2 17.6 11.1 353 4 358 305 8.1 0 8.2 7.9 08/29/2005 11:40:00 13.1 1 16.1 10.3 13.3 1.1 16.4 9.9 353 4 350 305 8.1 0 8.2 7.9 08/29/2005 11:50:00 13.6 1 16.4 10.7 13.7 1.1 16.1 10.7 355 4 358 305 8.1 0 8.2 7.9 08/29/2005 12:00:00 13.5 1.2 17.2 10.3 13.5 1.3 17.2 9.5 0 5 2 305 8.1 0 8.2 8.2 08/29/2005 12:10:00 13.2 1 16.1 10.7 13.3 1.1 16.4 10.3 358 5 350 305 8.2 0 8.4 8.2 08/29/2005 12:20:00 12.2 1.1 14.9 9.5 12.2 1.2 15.3 9.1 353 4 351 305 8.5 0 8.7 8.2 08/29/2005 12:30:00 11.9 1 14.5 9.1 12 1.1 14.9 9.1 352 4 4 305 8.7 0 8.9 8.4 08/29/2005 12:40:00 11.6 1 13.7 8.8 11.6 1.1 14.1 9.1 354 5 355 305 8.7 0 8.9 8.4 08/29/2005 12:50:00 12.1 1 14.9 9.1 12.2 1.1 16.4 9.1 352 5 351 305 8.6 0 8.7 8.4 08/29/2005 13:00:00 12.7 1 15.3 10.3 12.8 1 16.1 9.9 353 4 354 305 8.6 0 8.9 8.4 08/29/2005 13:10:00 13 1 15.3 10.7 12.9 1.1 15.6 9.9 358 5 358 305 8.7 0 8.9 8.4 08/29/2005 13:20:00 11.9 1.1 14.9 9.1 12 1.1 14.9 9.5 351 5 349 305 9 0 9.2 8.9 08/29/2005 13:30:00 11.2 0.9 13.7 9.1 11.3 1 14.1 8.4 348 4 353 305 9.1 0 9.2 8.9 08/29/2005 13:40:00 11.4 0.9 14.1 9.1 11.5 1 14.1 8.4 352 4 347 305 9 0.1 9.2 8.7 08/29/2005 13:50:00 11.4 0.9 13.7 8.8 11.5 1 13.7 8 349 5 0 305 9.1 0.1 9.5 8.9 08/29/2005 14:00:00 10.7 0.8 13 8.4 10.8 0.9 13 8 352 4 353 305 9.3 0 9.7 9.2 08/29/2005 14:10:00 10.4 0.9 12.6 8 10.4 1 12.6 8.4 354 4 355 305 9.3 0 9.5 9.2 08/29/2005 14:20:00 9.8 0.8 12.2 8 9.9 1 12.2 7.2 353 5 354 305 9.2 0 9.5 9.2 08/29/2005 14:30:00 9.5 0.8 11.8 7.6 9.6 0.9 12.2 7.2 358 5 2 305 9.2 0 9.5 9.2 08/29/2005 14:40:00 9.9 0.8 11.8 7.6 10.1 0.9 12.6 7.2 358 5 358 305 9.2 0 9.5 9.2 08/29/2005 14:50:00 10.1 0.8 11.8 8 10.2 0.9 12.6 8 358 4 355 305 9.2 0 9.5 9.2 08/29/2005 15:00:00 10.1 0.7 11.8 8.4 10.1 0.8 12.2 8 0 4 354 305 9.2 0 9.5 9.2 08/29/2005 15:10:00 10.2 0.9 12.2 7.6 10.3 0.9 12.6 7.2 3 5 0 305 9 0 9.2 8.9 08/29/2005 15:20:00 10.6 0.8 12.6 8 10.7 1 13 8 2 4 4 305 8.9 0 9.2 8.9 08/29/2005 15:30:00 10.9 0.9 13 8.8 11.1 1 13.3 8.8 3 4 5 305 8.9 0 9.2 8.9 08/29/2005 15:40:00 11.3 0.8 13.7 9.5 11.3 0.9 13.7 9.1 3 4 357 305 9.1 0 9.5 8.9 08/29/2005 15:50:00 11 0.9 13 8.8 11.1 0.9 13.3 8.4 4 4 2 305 9.1 0 9.5 9.2 08/29/2005 16:00:00 11.2 0.9 13.3 8.8 11.2 0.9 13.3 8.8 4 5 9 305 9.2 0 9.5 8.9 08/29/2005 16:10:00 10.3 0.9 12.2 8 10.4 1 12.6 7.6 3 4 3 305 9.2 0 9.2 9.2 08/29/2005 16:20:00 10.3 0.8 12.2 8 10.4 0.8 12.2 8.4 4 3 4 305 9.1 0 9.2 8.9 08/29/2005 16:30:00 10.3 0.9 12.6 8 10.4 1 13 7.6 2 4 4 305 9.2 0 9.5 9.2 08/29/2005 16:40:00 10.4 0.8 13 8.4 10.6 0.8 12.6 8.4 4 3 4 305 9.1 0 9.5 8.9 08/29/2005 16:50:00 10.7 0.9 14.1 8 10.8 0.9 13 8.4 5 4 4 305 9.2 0 9.5 8.9 08/29/2005 17:00:00 10.6 1 13.3 8.4 10.7 1 13 8.8 6 4 2 305 9.2 0 9.5 9.2 08/29/2005 17:10:00 11.4 0.9 13.3 8 11.4 0.9 13.3 8.4 8 4 8 305 9.2 0 9.5 9.2 08/29/2005 17:20:00 11 0.8 13 9.1 11.1 0.8 13.3 9.1 5 3 6 305 9.3 0 9.5 9.2 08/29/2005 17:30:00 10.2 0.7 12.2 8.4 10.3 0.7 12.2 8.4 3 4 2 305 9.4 0 9.7 9.2 08/29/2005 17:40:00 10.6 0.9 13 8 10.6 0.9 13 8 6 3 2 305 9.3 0 9.7 9.2 08/29/2005 17:50:00 10.2 0.7 11.5 8.4 10.2 0.7 12.2 8.4 3 3 3 305 9.3 0.1 9.7 9.2 08/29/2005 18:00:00 9.4 0.6 10.7 7.6 9.5 0.6 11.1 7.2 2 3 356 305 9.2 0 9.2 9.2 08/29/2005 18:10:00 8.9 0.8 11.8 7.2 8.9 0.7 11.8 6.8 1 3 3 305 9.2 0 9.5 9.2 08/29/2005 18:20:00 8.2 0.6 9.9 6.8 8.3 0.6 9.5 6.5 359 3 356 305 9.2 0 9.5 9.2 08/29/2005 18:30:00 8.2 0.6 10.3 6.1 8.4 0.6 10.3 6.5 1 5 8 305 9.2 0 9.5 9.2 08/29/2005 18:40:00 10 0.5 11.5 8.4 10.1 0.6 11.1 8.4 4 3 4 305 9.2 0 9.5 9.2 08/29/2005 18:50:00 9.8 0.6 11.5 8.4 9.8 0.7 11.8 8 6 3 5 305 9.3 0 9.5 9.2 08/29/2005 19:00:00 8.4 0.6 9.9 6.5 8.5 0.6 10.3 6.8 359 4 1 305 9.2 0 9.5 9.2 08/29/2005 19:10:00 7.2 0.9 9.9 5.3 7.3 0.9 9.9 5.3 359 3 359 305 9.1 0 9.2 8.9 08/29/2005 19:20:00 5.8 0.5 7.2 4.6 5.9 0.5 7.6 4.6 8 5 5 305 9.1 0 9.2 8.9 08/29/2005 19:30:00 7.2 0.6 8.8 5.7 7.4 0.6 8.8 4.9 6 3 5 305 9.1 0 9.2 9.2 08/29/2005 19:40:00 8 0.6 9.9 6.5 8 0.7 9.5 6.5 5 3 7 305 9.2 0 9.2 9.2 08/29/2005 19:50:00 7.2 0.6 8.4 5.7 7.1 0.5 8.4 5.7 5 3 4 305 9.2 0 9.2 9.2 08/29/2005 20:00:00 7.6 0.7 9.9 5.7 7.6 0.7 9.5 6.1 3 4 5 305 9.1 0 9.2 8.9 08/29/2005 20:10:00 7.6 0.5 8.8 6.1 7.6 0.6 9.1 6.1 1 3 1 305 8.9 0 9.2 8.9 08/29/2005 20:20:00 7.9 0.6 10.3 6.5 8 0.7 10.3 6.1 4 4 1 305 8.9 0 9.2 8.9 08/29/2005 20:30:00 8.9 0.6 10.7 7.2 9 0.7 10.7 7.2 5 3 2 305 8.8 0 8.9 8.7 08/29/2005 20:40:00 7.7 0.9 9.9 6.1 7.9 0.9 10.3 6.1 7 4 8 305 8.6 0 8.9 8.4 08/29/2005 20:50:00 8.5 0.9 11.5 6.1 8.5 0.8 11.8 6.5 6 5 10 305 8.5 0 8.7 8.4 08/29/2005 21:00:00 9.5 0.5 10.7 8 9.6 0.6 11.5 7.6 1 3 4 305 8.3 0 8.4 8.2 08/29/2005 21:10:00 8.9 0.5 10.7 7.2 9 0.6 10.7 7.2 6 3 7 305 8.2 0 8.4 8.2 08/29/2005 21:20:00 8.7 0.6 10.7 7.2 8.8 0.6 10.7 7.2 5 3 9 305 8.2 0 8.2 8.2 08/29/2005 21:30:00 9.1 0.7 11.1 7.2 9.3 0.7 11.1 7.2 4 4 6 305 8.2 0 8.2 8.2 08/29/2005 21:40:00 9.8 0.6 11.8 8.4 10 0.6 11.8 8 7 3 4 305 8.1 0 8.2 8.2 08/29/2005 21:50:00 10.2 0.6 11.8 8.4 10.3 0.6 11.8 8.8 7 3 1 305 8.1 0 8.2 7.9 08/29/2005 22:00:00 9.4 0.7 11.5 7.6 9.4 0.8 11.8 7.2 10 4 12 305 8 0 8.2 7.9 08/29/2005 22:10:00 8.4 0.6 9.9 6.8 8.5 0.6 10.3 6.8 11 5 9 305 8 0 8.2 7.9 08/29/2005 22:20:00 8.8 0.7 10.7 7.6 8.9 0.7 11.1 7.6 8 4 5 305 8 0 8.2 7.9 08/29/2005 22:30:00 9.1 0.7 10.7 7.2 9.2 0.8 11.1 6.8 6 4 5 305 7.9 0 7.9 7.9 08/29/2005 22:40:00 9 0.6 11.1 7.2 9.2 0.6 10.7 7.2 7 4 6 305 7.9 0 7.9 7.7 08/29/2005 22:50:00 9.2 0.6 10.7 7.6 9.3 0.6 10.7 7.6 5 4 7 305 7.8 0 7.9 7.7 08/29/2005 23:00:00 8.9 0.6 10.7 7.2 9.1 0.6 10.7 6.8 8 3 12 305 7.7 0 7.9 7.7 08/29/2005 23:10:00 7.8 0.9 9.9 5.7 8 0.9 9.9 5.7 9 4 4 305 7.7 0 7.9 7.7 08/29/2005 23:20:00 6.1 0.6 7.6 4.6 6.2 0.6 8 4.9 13 4 8 305 7.5 0 7.7 7.4 08/29/2005 23:30:00 6.6 0.6 8 4.9 6.7 0.6 8 5.3 7 4 0 305 7.5 0 7.7 7.4 08/29/2005 23:40:00 6.4 0.5 7.6 5.3 6.6 0.5 8 5.3 3 3 1 305 7.4 0 7.7 7.4 08/29/2005 23:50:00 6.5 0.6 7.6 4.6 6.7 0.6 8 4.9 6 4 8 305 7.4 0 7.7 7.4 08/30/2005 00:00:00 4.7 0.5 5.7 3.8 4.9 0.5 6.1 3.8 3 4 0 305 7.4 0 7.9 7.4 08/30/2005 00:10:00 4.8 0.4 5.7 3.8 5 0.4 6.1 3.8 4 4 4 305 7.3 0 7.4 7.4 08/30/2005 00:20:00 4 0.4 4.9 3 4 0.5 5.3 3 7 5 3 305 7.4 0 7.7 7.4 08/30/2005 00:30:00 4.1 0.4 4.9 3.4 4.1 0.4 4.9 3 3 4 4 305 7.4 0 7.7 7.4 08/30/2005 00:40:00 3.7 0.3 4.6 3 3.7 0.4 4.6 3 12 7 4 305 7.3 0 7.4 7.4 08/30/2005 00:50:00 4.3 0.4 5.3 3.4 4.3 0.4 5.7 3 13 5 8 305 7.3 0 7.4 7.2 08/30/2005 01:00:00 3.6 0.5 4.6 2.6 3.6 0.5 4.6 2.6 13 5 17 305 7.4 0 7.7 7.4 08/30/2005 01:10:00 3.1 0.4 4.6 2.3 3.1 0.4 4.2 2.3 349 10 341 305 7.5 0 7.7 7.4 08/30/2005 01:20:00 1.8 0.4 2.6 1.1 1.9 0.3 2.6 1.1 340 6 338 305 7.5 0 7.7 7.4 08/30/2005 01:30:00 1.6 0.6 3 0.4 1.5 0.4 2.6 0.4 351 11 338 305 7.5 0 7.7 7.4 08/30/2005 01:40:00 0.5 0.3 1.5 0.4 1 0.4 1.9 0.4 46 28 13 305 7.6 0 7.7 7.4 08/30/2005 01:50:00 0.5 0.3 1.9 0.4 1.1 0.4 2.3 0.4 24 27 26 305 7.7 0 7.9 7.7 08/30/2005 02:00:00 0.8 0.5 2.6 0.4 1.1 0.6 2.6 0.4 348 11 355 305 7.7 0 7.9 7.7 08/30/2005 02:10:00 1.6 0.4 2.6 0.4 1.9 0.3 2.6 1.1 0 7 2 305 7.8 0 7.9 7.7 08/30/2005 02:20:00 1.5 0.4 2.3 0.4 1.8 0.4 2.6 0.7 5 13 349 305 7.9 0 8.2 7.7 08/30/2005 02:30:00 1 0.6 2.3 0.4 1.4 0.6 2.6 0.4 4 5 9 305 7.9 0 7.9 7.7 08/30/2005 02:40:00 0.4 0.1 1.1 0.4 0.8 0.3 1.5 0.4 1 4 0 305 7.9 0 7.9 7.7 08/30/2005 02:50:00 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 14 2 21 305 7.8 0 7.9 7.7 08/30/2005 03:00:00 0.6 0.5 1.9 0.4 1 0.5 2.3 0.4 257 61 227 305 7.9 0 7.9 7.7 08/30/2005 03:10:00 1 0.3 1.9 0.4 1.5 0.2 1.9 1.1 223 5 233 305 7.7 0.1 7.9 7.7 08/30/2005 03:20:00 1.2 0.4 2.3 0.4 1.4 0.4 2.3 0.4 232 9 232 305 7.7 0 7.9 7.7 08/30/2005 03:30:00 1.7 0.8 3.4 0.4 1.7 0.6 3.4 0.4 243 12 268 305 7.8 0 7.9 7.7 08/30/2005 03:40:00 2.5 0.5 3.8 1.5 2 0.4 3 1.1 256 9 261 305 8 0 8.2 7.9 08/30/2005 03:50:00 3 0.4 4.6 1.5 2.6 0.4 3.8 1.5 252 9 259 305 8 0 8.2 7.9 08/30/2005 04:00:00 2.5 0.5 3.8 1.1 2.3 0.4 3.4 1.5 238 10 239 305 8 0 8.2 7.9 08/30/2005 04:10:00 2.5 0.5 4.2 1.1 2.7 0.4 3.8 1.5 228 12 238 305 8 0 8.2 7.9 08/30/2005 04:20:00 3 0.6 4.6 1.5 2.8 0.4 3.8 1.9 234 11 244 305 8 0 8.2 7.9 08/30/2005 04:30:00 2.9 0.5 4.2 1.9 2.8 0.3 3.4 1.5 226 10 242 305 7.9 0 7.9 7.7 08/30/2005 04:40:00 3 0.5 4.2 1.1 2.8 0.4 3.8 1.9 228 13 210 305 7.9 0 8.2 7.7 08/30/2005 04:50:00 2.7 0.6 4.2 0.7 2.7 0.4 4.2 1.5 229 13 232 305 7.8 0 7.9 7.7 08/30/2005 05:00:00 2.3 0.4 3.4 1.1 2.4 0.4 3.8 1.5 229 15 256 305 7.7 0 7.9 7.7 08/30/2005 05:10:00 2 0.6 3.8 0.4 2.1 0.5 3.8 0.7 242 13 230 305 7.6 0 7.7 7.7 08/30/2005 05:20:00 2.1 0.5 3.4 1.1 1.9 0.4 3 1.1 252 12 252 305 7.5 0 7.7 7.4 08/30/2005 05:30:00 1.5 0.6 3 0.4 1.7 0.4 3 0.4 239 15 254 305 7.5 0 7.7 7.4 08/30/2005 05:40:00 1.7 0.6 3 0.4 1.9 0.5 3.4 0.7 234 17 249 305 7.7 0 7.9 7.7 08/30/2005 05:50:00 1.8 0.6 3 0.4 2.1 0.5 3.4 0.7 239 16 236 305 7.7 0 7.9 7.7 08/30/2005 06:00:00 2 0.6 3 0.4 2 0.4 3 0.7 231 15 246 305 7.7 0 7.9 7.7 08/30/2005 06:10:00 1.2 0.7 3.8 0.4 1.5 0.5 2.6 0.4 255 24 220 305 7.7 0 7.9 7.7 08/30/2005 06:20:00 1.2 0.6 2.6 0.4 1.3 0.3 2.3 0.7 257 15 262 305 7.6 0 7.9 7.7 08/30/2005 06:30:00 0.7 0.5 2.6 0.4 1.1 0.5 2.3 0.4 243 24 246 305 7.5 0 7.7 7.4 08/30/2005 06:40:00 0.5 0.3 1.9 0.4 1.1 0.5 2.3 0.4 204 33 197 305 7.6 0 7.7 7.7 08/30/2005 06:50:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 168 98 241 305 7.5 0 7.7 7.2 08/30/2005 07:00:00 0.5 0.3 1.9 0.4 0.9 0.4 1.9 0.4 252 29 245 305 7.4 0.1 7.9 7.2 08/30/2005 07:10:00 0.6 0.3 1.5 0.4 1.4 0.2 1.9 0.7 216 13 219 305 7.7 0 8.2 7.7 08/30/2005 07:20:00 1.4 0.4 2.6 0.4 1.7 0.3 2.6 1.1 223 12 231 305 7.8 0.1 8.2 7.7 08/30/2005 07:30:00 0.5 0.3 1.9 0.4 0.9 0.5 2.6 0.4 252 61 213 305 7.9 0 8.2 7.7 08/30/2005 07:40:00 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 262 58 13 305 7.7 0 8.2 7.7 08/30/2005 07:50:00 0.4 0.1 1.5 0.4 0.8 0.4 1.5 0.4 102 66 10 305 7.6 0 7.9 7.4 08/30/2005 08:00:00 0.4 0.2 1.1 0.4 0.9 0.4 2.3 0.4 183 11 207 305 7.9 0.1 8.4 7.7 08/30/2005 08:10:00 0.4 0.2 1.1 0.4 1 0.4 1.9 0.4 189 13 194 305 8.2 0 8.4 8.2 08/30/2005 08:20:00 0.4 0.2 1.5 0.4 0.8 0.4 1.9 0.4 200 27 197 305 8.5 0 8.9 8.2 08/30/2005 08:30:00 0.6 0.4 1.9 0.4 0.9 0.5 1.9 0.4 233 22 263 305 8.7 0 8.9 8.4 08/30/2005 08:40:00 1.1 0.6 2.6 0.4 1.5 0.5 2.6 0.4 230 13 241 305 8.8 0 8.9 8.7 08/30/2005 08:50:00 0.9 0.5 1.9 0.4 1.7 0.4 2.3 0.7 197 24 226 305 8.9 0 9.2 8.7 08/30/2005 09:00:00 0.9 0.5 2.6 0.4 1.4 0.4 2.3 0.7 198 19 208 305 9.1 0 9.2 8.9 08/30/2005 09:10:00 0.8 0.6 2.3 0.4 1.2 0.5 2.3 0.4 227 28 272 305 9.2 0 9.5 9.2 08/30/2005 09:20:00 0.6 0.4 1.9 0.4 1.1 0.5 2.3 0.4 218 43 261 305 9.5 0.1 10 9.2 08/30/2005 09:30:00 0.5 0.2 1.5 0.4 0.9 0.5 1.9 0.4 211 22 231 305 10.1 0 10.2 9.7 08/30/2005 09:40:00 1.5 0.5 2.6 0.4 2 0.4 3 0.7 209 22 181 305 9.9 0 10 9.7 08/30/2005 09:50:00 1.2 0.7 3 0.4 1.7 0.6 2.6 0.4 204 19 196 305 9.7 0 10 9.7 08/30/2005 10:00:00 1.1 0.8 3 0.4 1.5 0.7 3.4 0.4 233 20 226 305 10.1 0 10.2 10 08/30/2005 10:10:00 1.7 0.8 3 0.4 1.9 0.7 3.4 0.4 226 27 268 305 9.9 0 10.2 9.7 08/30/2005 10:20:00 1.4 0.7 3 0.4 1.9 0.5 3 0.7 219 22 203 305 9.7 0 10 9.7 08/30/2005 10:30:00 1.3 0.7 3 0.4 1.6 0.6 3 0.4 227 30 217 305 9.9 0 10 9.7 08/30/2005 10:40:00 1.3 0.7 3.4 0.4 1.6 0.7 3 0.4 233 35 228 305 9.9 0 10 9.7 08/30/2005 10:50:00 1.3 0.8 4.6 0.4 1.6 0.7 3.8 0.4 228 33 210 305 10 0 10.2 9.7 08/30/2005 11:00:00 1.9 0.7 4.2 0.4 2 0.5 3.4 0.7 244 24 283 305 10.1 0 10.2 10 08/30/2005 11:10:00 2.3 0.7 4.2 0.4 2.3 0.6 3.8 0.4 251 20 259 305 10.1 0 10.2 10 08/30/2005 11:20:00 2.5 0.7 4.2 1.1 2.4 0.6 3.8 1.1 247 18 262 305 10.2 0 10.2 10.2 08/30/2005 11:30:00 2.2 0.6 3.8 0.4 2.2 0.6 3.4 0.7 249 24 196 305 10.2 0 10.5 10.2 08/30/2005 11:40:00 2 0.6 3.4 0.4 2.2 0.6 3.4 0.7 222 20 218 305 10.3 0 10.5 10.2 08/30/2005 11:50:00 2.3 0.8 4.6 0.4 2.3 0.7 4.6 0.4 239 29 265 305 10.2 0 10.2 10 08/30/2005 12:00:00 1.7 0.7 3 0.4 2.1 0.6 3.4 0.7 212 23 246 305 10.4 0 10.5 10.2 08/30/2005 12:10:00 1.8 0.7 3.4 0.4 1.8 0.5 3 0.4 236 38 215 305 10.4 0.1 10.8 10.2 08/30/2005 12:20:00 2.4 0.8 4.2 0.4 2.4 0.7 4.2 0.4 258 20 283 305 10.5 0 10.8 10.5 08/30/2005 12:30:00 1.6 0.8 3.4 0.4 1.7 0.8 3.8 0.4 235 30 234 305 10.6 0 10.8 10.5 08/30/2005 12:40:00 1.7 0.9 3.8 0.4 1.7 0.8 3.4 0.4 215 38 203 305 11 0 11.3 10.8 08/30/2005 12:50:00 2.3 0.7 3.8 0.7 2.5 0.5 3.8 1.5 209 17 238 305 10.8 0 11 10.5 08/30/2005 13:00:00 2.1 0.9 4.6 0.4 2.1 0.8 3.8 0.4 230 27 218 305 10.8 0 11 10.5 08/30/2005 13:10:00 2.1 0.8 4.6 0.4 2.1 0.8 3.8 0.4 211 22 218 305 11 0 11 10.8 08/30/2005 13:20:00 2.1 0.8 3.8 0.4 2.1 0.6 3.8 0.4 219 22 221 305 11 0 11.3 10.8 08/30/2005 13:30:00 2.5 0.8 4.6 0.4 2.7 0.6 4.6 1.1 227 17 245 305 11.1 0 11.3 10.8 08/30/2005 13:40:00 3 0.7 4.9 1.1 3.1 0.7 4.9 1.5 229 21 251 305 11.1 0.1 11.3 10.8 08/30/2005 13:50:00 3.2 0.6 5.3 1.5 3.2 0.6 4.6 1.5 222 19 254 305 11.1 0 11.3 11 08/30/2005 14:00:00 2.8 0.6 3.8 1.1 2.8 0.5 4.2 1.1 221 18 238 305 11.3 0 11.6 11 08/30/2005 14:10:00 3.3 0.9 5.7 1.1 3.1 0.7 4.9 1.1 237 22 268 305 11.4 0.1 11.6 11 08/30/2005 14:20:00 4.5 1 7.2 2.6 4.1 1 7.6 2.3 260 12 251 305 11.4 0.2 11.8 11 08/30/2005 14:30:00 4.1 0.7 6.1 2.3 3.8 0.7 6.1 1.9 253 13 233 305 11.1 0.1 11.3 11 08/30/2005 14:40:00 4 0.8 6.1 1.9 3.7 0.7 6.1 1.9 262 17 240 305 11.4 0 11.6 11.3 08/30/2005 14:50:00 4.3 0.7 6.1 2.6 4 0.9 6.5 1.9 257 11 251 305 11.4 0 11.6 11 08/30/2005 15:00:00 4.3 0.8 6.1 2.6 4 0.8 5.7 1.9 258 13 254 305 11.2 0 11.3 11 08/30/2005 15:10:00 4.7 0.8 6.8 3 4.2 0.8 6.5 2.3 254 12 251 305 11.2 0 11.3 11 08/30/2005 15:20:00 5.1 0.8 7.6 3.4 4.5 0.8 6.8 2.6 258 10 276 305 11.2 0 11.3 11 08/30/2005 15:30:00 4.9 0.8 7.6 3 4.3 0.8 6.8 2.3 260 10 265 305 11.4 0 11.6 11 08/30/2005 15:40:00 5.1 0.7 7.2 3.4 4.7 0.8 7.2 3 257 10 266 305 11.3 0 11.3 11 08/30/2005 15:50:00 5.1 0.9 7.2 3 4.7 1 6.8 2.6 257 10 263 305 11.2 0.1 11.6 10.8 08/30/2005 16:00:00 5.3 0.8 7.2 3 4.9 0.9 7.2 2.6 254 10 253 305 10.9 0 11 10.5 08/30/2005 16:10:00 5.3 0.9 7.6 3 4.8 1 7.2 2.6 257 10 258 305 10.6 0.2 11 10.2 08/30/2005 16:20:00 6.1 1 8 3.4 5.4 0.9 7.2 3.4 257 9 258 305 10.2 0 10.5 9.7 08/30/2005 16:30:00 6.5 0.7 8.4 4.2 5.6 0.8 7.6 3.4 261 7 250 305 9.2 0.1 9.7 8.9 08/30/2005 16:40:00 5.6 1.1 8 3 5 0.9 7.2 3 260 10 270 305 8.9 0 9.2 8.7 08/30/2005 16:50:00 5 0.8 6.8 3 5 0.8 6.8 3.4 244 9 242 305 8.7 0 8.9 8.7 08/30/2005 17:00:00 5.6 0.8 7.2 3.4 5.5 0.8 7.6 3.4 252 8 248 305 8.6 0 8.9 8.4 08/30/2005 17:10:00 5.5 1 7.6 3.4 5.2 0.8 6.8 3.4 249 12 269 305 8.4 0 8.4 8.2 08/30/2005 17:20:00 5.3 0.8 7.6 3.8 5.3 0.8 8 3.4 245 9 251 305 8.6 0 8.9 8.4 08/30/2005 17:30:00 5.3 0.9 7.2 3 5 1 7.2 2.6 254 11 253 305 8.4 0 8.7 8.2 08/30/2005 17:40:00 5.1 1 7.6 3 4.7 1 7.6 2.3 254 9 263 305 8.6 0 8.7 8.4 08/30/2005 17:50:00 5.7 0.9 8 3 5.6 0.9 7.2 3.4 252 7 260 305 8.4 0 8.4 8.2 08/30/2005 18:00:00 5 0.8 7.2 3 4.8 0.8 6.8 3 249 9 248 305 8.5 0 8.7 8.4 08/30/2005 18:10:00 4 0.6 5.7 2.6 3.8 0.5 5.3 2.6 239 11 246 305 8.6 0 8.7 8.4 08/30/2005 18:20:00 4.9 0.7 6.5 2.6 4.7 0.8 6.8 2.6 250 8 250 305 8.6 0 8.9 8.4 08/30/2005 18:30:00 4.8 0.6 6.5 3.4 4.6 0.7 6.5 3 251 8 255 305 8.6 0 8.7 8.4 08/30/2005 18:40:00 4.5 0.7 6.1 2.6 4.2 0.6 5.7 2.6 253 10 254 305 8.6 0 8.9 8.4 08/30/2005 18:50:00 4.7 0.6 6.5 3 4.4 0.7 6.1 2.6 244 12 254 305 8.6 0 8.7 8.4 08/30/2005 19:00:00 4.2 0.7 6.1 2.6 3.7 0.7 5.7 1.9 251 13 246 305 8.6 0 8.9 8.4 08/30/2005 19:10:00 4.1 0.7 5.7 1.9 3.8 0.7 5.7 1.9 251 9 264 305 8.6 0 8.9 8.4 08/30/2005 19:20:00 4.5 0.7 6.5 2.6 4 0.6 6.1 2.3 255 9 262 305 8.8 0 8.9 8.7 08/30/2005 19:30:00 4.4 0.6 6.1 2.6 4.2 0.7 5.7 2.3 255 9 252 305 8.8 0 8.9 8.7 08/30/2005 19:40:00 4.2 0.6 6.1 3 3.6 0.6 4.9 2.3 261 10 261 305 8.7 0 8.9 8.7 08/30/2005 19:50:00 3.6 0.6 5.3 1.9 3.2 0.7 5.3 1.1 262 10 245 305 8.6 0 8.7 8.4 08/30/2005 20:00:00 4 0.6 5.7 2.6 3.4 0.6 5.3 1.9 262 11 276 305 8.4 0 8.4 8.4 08/30/2005 20:10:00 3.2 0.8 4.9 1.1 2.9 0.7 4.9 1.1 257 9 256 305 8.4 0 8.4 8.2 08/30/2005 20:20:00 4 0.6 5.7 2.6 3.9 0.5 5.3 2.6 249 9 253 305 8.3 0 8.4 8.2 08/30/2005 20:30:00 3.3 0.6 4.6 1.5 3.1 0.6 4.6 1.5 255 10 247 305 8.3 0 8.4 8.2 08/30/2005 20:40:00 3.7 0.6 5.3 1.9 3.3 0.5 4.6 1.9 252 13 250 305 8.2 0 8.4 8.2 08/30/2005 20:50:00 3.6 0.6 4.9 1.9 3.2 0.6 4.6 1.5 254 9 252 305 8.2 0 8.4 8.2 08/30/2005 21:00:00 2.8 0.5 3.8 1.9 2.8 0.5 3.8 1.5 251 9 249 305 8.1 0 8.2 7.9 08/30/2005 21:10:00 3 0.6 4.6 1.9 2.7 0.5 3.8 1.5 257 8 266 305 8.1 0 8.2 7.9 08/30/2005 21:20:00 3.4 0.9 4.9 0.7 2.7 0.7 4.2 1.1 265 7 266 305 8 0 8.2 7.9 08/30/2005 21:30:00 1.9 0.5 3 0.4 1.8 0.4 3 0.7 265 10 276 305 8 0 8.2 7.9 08/30/2005 21:40:00 1.6 0.5 2.6 0.4 1.9 0.4 2.6 1.1 309 22 308 305 8 0 8.2 7.9 08/30/2005 21:50:00 2.3 0.4 3.4 1.1 2.4 0.4 3.4 1.5 315 5 310 305 8 0 8.2 7.9 08/30/2005 22:00:00 2.3 0.3 3 1.1 2.4 0.3 3 1.5 324 4 315 305 8 0 7.9 7.9 08/30/2005 22:10:00 2.3 0.3 3.4 1.9 2.5 0.3 3.4 1.9 324 7 336 305 8 0 8.2 7.9 08/30/2005 22:20:00 1.9 0.3 2.6 1.1 2.2 0.3 3 1.1 346 4 351 305 7.9 0 8.2 7.9 08/30/2005 22:30:00 2.3 0.3 3 1.5 2.6 0.4 3.4 1.5 353 4 351 305 7.9 0 7.9 7.7 08/30/2005 22:40:00 1.6 1 3 0.4 2 1 3.8 0.4 354 9 354 305 7.8 0 7.9 7.7 08/30/2005 22:50:00 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 343 1 305 305 7.9 0 7.9 7.7 08/30/2005 23:00:00 1.4 0.7 3 0.4 1.9 0.6 3 0.7 11 15 11 305 7.8 0 7.9 7.7 08/30/2005 23:10:00 2.1 0.7 3.4 0.7 2.4 0.5 3.4 1.5 33 10 27 305 7.7 0 7.9 7.7 08/30/2005 23:20:00 2.7 0.6 3.8 1.5 2.9 0.5 4.2 1.5 44 11 40 305 7.7 0 7.7 7.7 08/30/2005 23:30:00 4.4 0.6 5.7 3 4.4 0.6 5.7 3 41 6 33 305 7.6 0 7.7 7.7 08/30/2005 23:40:00 5.3 0.6 6.5 3.8 5.3 0.5 6.5 4.2 45 5 51 305 7.5 0 7.7 7.4 08/30/2005 23:50:00 6.2 0.4 7.6 5.3 6.1 0.5 7.6 4.6 53 7 65 305 7.3 0 7.4 7.2 08/31/2005 00:00:00 8.5 1.2 11.1 4.9 8.3 1.1 10.7 4.6 63 5 71 305 7.1 0 7.7 6.9 08/31/2005 00:10:00 9.2 0.7 11.1 7.2 9 0.7 10.3 6.5 67 6 65 305 6.8 0 7.2 6.7 08/31/2005 00:20:00 9.4 0.7 11.1 7.2 9.3 0.8 11.1 7.2 70 5 70 305 6.7 0 6.9 6.7 08/31/2005 00:30:00 9.2 0.7 10.7 7.2 9.1 0.7 10.3 6.8 69 4 70 305 6.7 0 6.9 6.7 08/31/2005 00:40:00 8.4 0.8 9.9 5.7 8.3 0.8 9.9 5.3 68 5 70 305 6.8 0 6.9 6.7 08/31/2005 00:50:00 7.7 1.1 9.9 4.6 7.5 1.1 9.9 4.6 77 8 79 305 6.8 0 6.9 6.9 08/31/2005 01:00:00 7.8 0.8 11.1 5.7 7.7 0.8 10.7 6.1 76 8 79 305 6.8 0 6.9 6.7 08/31/2005 01:10:00 8 1 10.7 6.1 7.8 0.9 10.7 5.3 73 9 63 305 6.8 0 6.9 6.7 08/31/2005 01:20:00 8 0.8 10.3 6.1 7.9 0.8 10.3 5.3 74 7 72 305 6.9 0 7.2 6.9 08/31/2005 01:30:00 7.4 0.9 10.3 5.3 7.2 0.8 9.9 5.3 75 9 69 305 7 0 7.2 6.9 08/31/2005 01:40:00 7.6 0.9 10.3 5.3 7.5 0.9 9.5 5.3 72 9 77 305 6.9 0 7.4 6.9 08/31/2005 01:50:00 8 0.9 11.1 6.5 7.9 0.8 10.7 5.7 74 8 76 305 6.8 0 7.2 6.9 08/31/2005 02:00:00 8.2 0.6 9.5 6.5 8.1 0.6 9.5 6.1 63 5 66 305 6.7 0.1 7.2 6.4 08/31/2005 02:10:00 8.6 0.3 9.5 7.6 8.6 0.4 9.9 7.2 61 3 67 305 6.5 0 7.2 6.4 08/31/2005 02:20:00 8.5 0.3 9.1 7.6 8.4 0.3 9.1 7.2 60 2 65 305 6.3 0 6.7 6.1 08/31/2005 02:30:00 8.7 0.4 9.5 7.6 8.6 0.4 9.5 7.2 61 2 58 305 6.2 0.1 6.7 5.9 08/31/2005 02:40:00 9.2 0.5 10.3 7.6 9.1 0.6 10.7 7.6 64 3 64 305 6 0.1 6.4 5.9 08/31/2005 02:50:00 9.2 0.8 11.5 6.5 9 0.8 10.7 6.5 65 5 71 305 5.9 0 6.4 5.9 08/31/2005 03:00:00 8.3 0.6 10.3 6.5 8.2 0.7 10.3 6.5 64 5 61 305 5.8 0 6.1 5.6 08/31/2005 03:10:00 8 0.6 9.1 6.5 7.9 0.6 9.1 5.7 62 5 61 305 5.6 0.1 6.1 5.4 08/31/2005 03:20:00 7.3 0.8 9.1 5.3 7.3 0.8 9.5 5.3 71 6 71 305 5.4 0 5.9 5.4 08/31/2005 03:30:00 6.8 0.8 8.8 5.3 6.7 0.8 8.8 4.9 74 8 59 305 5.4 0 5.9 5.4 08/31/2005 03:40:00 6.2 0.8 8 4.6 6.1 0.8 8 4.2 78 10 67 305 5.4 0 5.6 5.4 08/31/2005 03:50:00 5.7 0.8 7.6 3.8 5.7 0.8 7.2 3.4 80 10 90 305 5.4 0 5.6 5.4 08/31/2005 04:00:00 6.4 1 8.8 4.2 6.4 1 9.1 3.8 75 9 73 305 5.4 0 5.9 5.4 08/31/2005 04:10:00 5.9 0.8 8 4.2 6 0.7 8.4 4.2 75 9 71 305 5.4 0 5.9 5.4 08/31/2005 04:20:00 5.8 0.9 10.7 3.8 5.6 0.9 9.5 4.2 81 10 88 305 5.4 0 5.9 5.4 08/31/2005 04:30:00 6.6 0.9 8.8 4.6 6.5 1 9.1 3.4 73 9 70 305 5.4 0 5.9 5.4 08/31/2005 04:40:00 6.6 0.8 9.1 4.6 6.6 0.7 8.4 4.9 69 7 77 305 5.4 0 5.9 5.4 08/31/2005 04:50:00 6.1 0.8 8 3.8 6 0.8 7.6 3.8 74 7 61 305 5.3 0 5.6 5.2 08/31/2005 05:00:00 5.8 0.7 7.6 4.2 5.6 0.7 8 4.2 72 9 65 305 5.2 0 5.6 5.2 08/31/2005 05:10:00 4.3 0.8 6.5 2.3 4.2 0.8 6.5 2.3 76 12 88 305 5.1 0 5.6 4.9 08/31/2005 05:20:00 4.9 1 7.6 3 4.9 1 7.6 2.6 73 12 83 305 4.8 0 5.4 4.9 08/31/2005 05:30:00 4.8 1.2 8.8 2.3 4.8 1.1 8 2.3 77 12 75 305 4.8 0 5.4 4.9 08/31/2005 05:40:00 5.4 0.9 7.2 3.4 5.4 0.9 7.6 3 72 12 56 305 4.8 0 5.4 4.7 08/31/2005 05:50:00 5.4 0.8 8.4 3.4 5.4 0.9 8 3.4 82 12 72 305 4.8 0 5.4 4.7 08/31/2005 06:00:00 6 0.9 8.8 4.2 6 0.9 8.4 3.8 88 12 82 305 4.9 0.1 5.4 4.7 08/31/2005 06:10:00 6.1 0.9 8.8 4.2 6.1 0.9 8.4 4.2 93 10 93 305 4.8 0 5.4 4.7 08/31/2005 06:20:00 6.9 0.8 8.8 4.9 6.9 0.8 8.8 4.9 96 7 93 305 4.7 0 5.4 4.4 08/31/2005 06:30:00 6.8 0.8 8.4 4.2 6.7 0.7 8.4 4.6 96 7 93 305 4.6 0 5.2 4.4 08/31/2005 06:40:00 6.8 0.7 8.4 5.3 6.8 0.7 8.8 5.3 97 6 87 305 4.7 0 4.9 4.4 08/31/2005 06:50:00 5.9 1.1 9.1 3.4 5.9 1 9.1 3.8 96 10 88 305 4.8 0 4.9 4.7 08/31/2005 07:00:00 5.5 0.8 7.2 3.8 5.5 0.9 8 3.4 90 12 94 305 4.8 0 4.9 4.7 08/31/2005 07:10:00 6.1 1 8 3.4 6.1 1 8 3 90 10 87 305 4.8 0 4.9 4.7 08/31/2005 07:20:00 6.2 0.9 8 3.8 6.1 1 8 3.8 96 8 102 305 4.7 0 4.9 4.7 08/31/2005 07:30:00 6.3 0.7 8 4.6 6.3 0.7 8.4 4.6 101 8 92 305 4.7 0 4.7 4.7 08/31/2005 07:40:00 6.9 0.9 8.8 4.6 6.8 0.9 8.8 4.2 104 8 107 305 4.7 0 4.9 4.7 08/31/2005 07:50:00 6.6 0.8 8.4 4.2 6.6 0.8 8.4 4.6 108 8 113 305 4.8 0 4.9 4.7 08/31/2005 08:00:00 6.1 1.1 8.4 3.4 6 1.1 8.4 3 114 7 106 305 4.8 0 4.9 4.7 08/31/2005 08:10:00 5.2 0.8 6.8 2.6 5.1 0.8 6.8 2.3 117 9 119 305 4.9 0 5.2 4.9 08/31/2005 08:20:00 5.6 0.8 7.2 3 5.5 0.8 8 2.6 122 8 121 305 5.1 0 5.4 4.9 08/31/2005 08:30:00 6.2 0.6 7.2 4.2 6.2 0.6 7.2 4.6 119 6 118 305 5.3 0 5.6 5.2 08/31/2005 08:40:00 5.8 0.8 7.2 3 5.8 0.8 7.2 3.4 121 7 120 305 5.5 0 5.9 5.4 08/31/2005 08:50:00 5.4 0.9 6.8 3 5.4 1 7.2 2.6 120 9 118 305 5.7 0 5.9 5.6 08/31/2005 09:00:00 5 1 6.5 3 4.8 1 6.5 1.5 126 9 116 305 6 0 6.4 5.9 08/31/2005 09:10:00 2.6 1.2 5.7 0.4 2.5 1.1 5.7 0.4 143 47 125 305 6 0 6.4 5.9 08/31/2005 09:20:00 2.5 1.1 5.3 0.4 2.5 0.9 4.6 0.4 137 45 118 305 6.3 0 6.4 6.1 08/31/2005 09:30:00 4.4 0.9 6.5 1.9 4.5 1 6.5 1.5 124 11 136 305 6.5 0 6.7 6.4 08/31/2005 09:40:00 3.7 0.6 5.3 1.9 3.9 0.6 5.3 2.3 130 10 140 305 6.7 0 6.9 6.4 08/31/2005 09:50:00 3.2 0.7 4.6 1.1 3.3 0.6 4.6 1.5 132 13 128 305 6.9 0 7.2 6.9 08/31/2005 10:00:00 3.2 0.6 4.6 1.5 3.4 0.5 4.6 1.9 128 10 132 305 7.5 0.1 7.7 7.2 08/31/2005 10:10:00 2.8 0.6 3.8 1.1 3.2 0.5 4.2 1.9 144 9 142 305 7.1 0 7.4 6.9 08/31/2005 10:20:00 2.7 0.5 3.8 1.1 3 0.4 4.2 1.9 126 13 140 305 7 0.1 7.4 6.9 08/31/2005 10:30:00 2.1 0.8 3.8 0.4 2.5 0.7 3.8 1.1 121 13 124 305 7.3 0 7.7 7.2 08/31/2005 10:40:00 1.6 1.1 4.2 0.4 2.3 1 4.6 0.4 146 18 153 305 7.4 0 7.7 7.2 08/31/2005 10:50:00 2 1.2 4.6 0.4 2.5 1 4.6 0.4 139 16 109 305 7.7 0.1 7.9 7.4 08/31/2005 11:00:00 1.1 0.8 3.8 0.4 1.6 0.7 3.4 0.4 125 24 108 305 8 0.2 8.4 7.7 08/31/2005 11:10:00 1.2 0.9 3.8 0.4 1.7 0.9 3.8 0.4 152 36 161 305 8.2 0 8.4 7.9 08/31/2005 11:20:00 1.7 0.7 3 0.4 2.1 0.6 3.4 0.4 168 32 140 305 8.1 0.1 8.4 7.9 08/31/2005 11:30:00 1 0.7 3 0.4 1.5 0.8 3 0.4 113 35 120 305 8.4 0.2 8.9 8.2 08/31/2005 11:40:00 2.5 0.7 4.2 0.7 2.8 0.6 4.2 1.5 215 24 225 305 7.9 0.4 8.9 7.4 08/31/2005 11:50:00 2.1 0.8 3.4 0.4 2.6 0.6 3.8 1.1 236 11 240 305 7.2 0 7.4 7.2 08/31/2005 12:00:00 2 0.7 4.2 0.4 2.3 0.6 3.8 0.7 238 12 242 305 7.1 0 7.2 6.9 08/31/2005 12:10:00 2.4 0.4 3.4 0.7 2.6 0.4 3.4 1.5 232 9 234 305 7 0 7.2 6.9 08/31/2005 12:20:00 2.4 0.5 3.8 1.1 2.7 0.4 3.8 1.5 229 8 243 305 7 0 7.4 7.2 08/31/2005 12:30:00 2.6 0.4 3.8 1.5 2.7 0.4 3.8 1.9 240 9 234 305 7 0 7.2 6.9 08/31/2005 12:40:00 2.6 0.9 4.2 0.4 2.8 0.8 4.6 1.1 229 10 237 305 7 0 7.4 6.9 08/31/2005 12:50:00 3.3 0.5 4.6 1.9 3.4 0.5 4.6 2.3 226 9 222 305 7.2 0 7.4 7.2 08/31/2005 13:00:00 2.8 0.8 4.6 0.4 3 0.6 4.2 1.5 205 15 218 305 7.2 0 7.4 7.2 08/31/2005 13:10:00 2.1 1 4.2 0.4 2.6 0.7 4.6 1.1 188 13 196 305 7.5 0 7.7 7.4 08/31/2005 13:20:00 2.5 0.5 4.2 1.1 2.6 0.4 3.8 1.5 209 17 201 305 7.6 0 7.7 7.4 08/31/2005 13:30:00 3.2 0.6 4.6 1.5 3.4 0.5 4.6 2.3 190 10 189 305 7.7 0 7.9 7.4 08/31/2005 13:40:00 4 0.6 5.3 2.3 4 0.7 5.7 2.3 201 8 201 305 7.6 0 7.9 7.4 08/31/2005 13:50:00 4.5 0.7 6.1 2.3 4.4 0.7 6.5 2.6 202 9 203 305 7.8 0 7.9 7.7 08/31/2005 14:00:00 4 0.6 5.3 2.3 4 0.6 5.3 2.3 208 7 203 305 7.8 0 7.9 7.7 08/31/2005 14:10:00 3.7 0.5 4.6 2.3 3.9 0.4 4.9 2.6 193 8 199 305 7.9 0 8.2 7.7 08/31/2005 14:20:00 3.7 0.5 4.9 2.3 3.9 0.5 4.9 2.3 191 8 188 305 8 0 8.2 7.9 08/31/2005 14:30:00 3.6 0.5 4.9 2.6 3.6 0.5 4.9 2.3 191 6 192 305 8.4 0 8.9 8.2 08/31/2005 14:40:00 3.9 0.5 4.9 1.9 4.1 0.5 5.7 3 190 6 189 305 9 0 9.5 8.7 08/31/2005 14:50:00 3.6 0.5 4.9 1.9 3.8 0.5 4.9 2.3 192 6 192 305 9.3 0 9.5 9.2 08/31/2005 15:00:00 2.9 0.5 4.2 1.9 3 0.5 4.6 1.9 195 10 203 305 9.5 0 9.7 9.2 08/31/2005 15:10:00 3.1 0.6 4.2 1.5 3.2 0.5 4.6 1.9 200 8 198 305 9.5 0 9.7 9.2 08/31/2005 15:20:00 3.5 0.6 5.3 2.3 3.5 0.6 4.6 1.9 209 8 213 305 9.6 0 9.7 9.5 08/31/2005 15:30:00 4 0.5 5.7 2.6 3.9 0.5 5.3 2.6 219 6 220 305 9.7 0 10 9.5 08/31/2005 15:40:00 3.8 0.5 4.9 2.6 3.7 0.5 5.3 2.6 211 8 214 305 9.7 0 9.7 9.5 08/31/2005 15:50:00 3.7 0.4 4.6 2.6 3.7 0.4 4.9 2.3 205 5 201 305 9.3 0 9.5 9.2 08/31/2005 16:00:00 4 0.4 5.3 3 4 0.4 5.3 2.6 210 7 203 305 9.3 0 9.5 9.2 08/31/2005 16:10:00 4.1 0.6 5.3 2.6 4 0.6 5.7 2.6 213 6 222 305 9.4 0.1 9.7 9.2 08/31/2005 16:20:00 4.1 0.5 5.3 2.6 4.1 0.5 4.9 3 219 8 214 305 9.7 0 10 9.5 08/31/2005 16:30:00 4.7 1 6.8 2.6 4.6 1 6.5 2.3 216 7 214 305 9.6 0 10 9.5 08/31/2005 16:40:00 4.9 0.6 6.5 3.4 4.7 0.7 6.5 2.6 210 7 215 305 9.3 0 9.7 9.2 08/31/2005 16:50:00 4.7 0.7 6.5 2.6 4.6 0.7 6.5 2.6 205 8 218 305 9.5 0.1 9.7 9.2 08/31/2005 17:00:00 4.1 0.4 5.3 3 4 0.5 4.9 2.6 203 9 218 305 9.6 0 10 9.5 08/31/2005 17:10:00 3.1 0.4 4.2 1.9 3.2 0.4 4.2 2.3 196 7 186 305 9.7 0 10 9.5 08/31/2005 17:20:00 4.7 1 6.8 2.6 4.6 1 6.8 2.6 219 11 223 305 9.3 0.3 9.7 8.9 08/31/2005 17:30:00 6.1 0.6 7.6 4.6 5.8 0.6 7.2 4.2 220 5 218 305 8.7 0 8.9 8.4 08/31/2005 17:40:00 6 0.6 7.6 4.6 5.7 0.6 7.6 4.2 213 6 212 305 8.6 0 8.7 8.4 08/31/2005 17:50:00 6.4 0.8 7.6 3.8 6.2 0.8 7.6 3.8 207 5 203 305 8.6 0 8.7 8.4 08/31/2005 18:00:00 6.7 0.5 8 4.9 6.5 0.6 7.6 4.6 204 5 212 305 8.7 0 8.9 8.7 08/31/2005 18:10:00 6.5 0.6 7.6 4.6 6.3 0.6 7.6 3.8 201 5 207 305 8.9 0 9.2 8.7 08/31/2005 18:20:00 6.3 0.5 7.6 4.9 6.2 0.6 7.6 4.6 204 4 208 305 9.1 0 9.2 8.9 08/31/2005 18:30:00 6.3 0.6 8 3.8 5.9 0.6 7.6 3.8 211 6 203 305 9.1 0 9.2 8.9 08/31/2005 18:40:00 7.1 0.7 8.4 4.9 6.7 0.8 8.4 4.6 210 5 213 305 8.9 0 8.9 8.9 08/31/2005 18:50:00 7.9 0.5 9.1 6.5 7.6 0.5 8.8 5.7 205 4 208 305 8.9 0 9.2 8.9 08/31/2005 19:00:00 7.6 0.5 8.8 5.7 7.3 0.6 8.8 4.9 204 4 204 305 8.9 0 9.2 8.9 08/31/2005 19:10:00 7.3 0.4 8.4 6.1 7.1 0.5 8 5.3 204 4 203 305 8.9 0 9.2 8.9 08/31/2005 19:20:00 7.2 0.5 8.4 5.3 7 0.6 8.4 4.9 203 4 198 305 9 0 9.2 8.9 08/31/2005 19:30:00 7.3 0.5 8.4 6.1 7.1 0.6 8.8 5.3 200 4 198 305 9.1 0 9.2 8.9 08/31/2005 19:40:00 7.2 0.5 8.4 5.7 7 0.7 8.4 4.9 200 4 205 305 9.2 0 9.2 9.2 08/31/2005 19:50:00 7 0.5 8 4.9 6.8 0.6 8 4.9 198 4 200 305 9.2 0 9.2 9.2 08/31/2005 20:00:00 7.1 0.6 8.4 4.9 6.9 0.7 8.4 4.6 198 4 196 305 9.2 0 9.5 9.2 08/31/2005 20:10:00 6.7 0.5 7.6 5.3 6.6 0.6 8 4.9 197 4 197 305 9.1 0 9.2 9.2 08/31/2005 20:20:00 6.8 0.5 8 5.3 6.8 0.6 8 4.9 196 4 191 305 9.2 0 9.5 9.2 08/31/2005 20:30:00 6.9 0.6 8 4.9 6.7 0.7 8 5.3 196 4 194 305 9.3 0 9.5 9.2 08/31/2005 20:40:00 7.2 0.5 8 4.9 7 0.7 8.4 4.9 197 5 190 305 9.4 0 9.5 9.2 08/31/2005 20:50:00 7.3 0.6 9.1 5.7 7.3 0.7 9.1 4.9 194 5 194 305 9.5 0 9.7 9.5 08/31/2005 21:00:00 7.1 0.7 8.8 4.9 7.2 0.8 8.8 4.9 189 5 188 305 9.6 0 9.7 9.5 08/31/2005 21:10:00 7 0.6 8.8 4.9 7.2 0.6 9.1 5.7 190 5 190 305 9.6 0 9.7 9.5 08/31/2005 21:20:00 7.7 0.7 9.5 5.3 7.6 1 9.1 4.9 195 5 196 305 9.6 0 9.7 9.5 08/31/2005 21:30:00 8 0.6 9.5 5.7 7.9 0.7 9.5 5.7 197 4 194 305 9.4 0 9.5 9.2 08/31/2005 21:40:00 7.6 0.6 8.8 5.7 7.4 0.7 8.8 5.7 197 4 202 305 9.3 0 9.5 9.2 08/31/2005 21:50:00 7.9 0.6 9.5 6.1 7.8 0.7 9.5 5.7 195 4 195 305 9.3 0 9.5 9.2 08/31/2005 22:00:00 7.9 0.6 9.1 5.7 7.8 0.7 9.1 6.1 196 4 196 305 9.2 0 9.5 9.2 08/31/2005 22:10:00 7.7 0.6 9.1 6.1 7.6 0.6 9.1 5.3 194 4 198 305 9.2 0 9.5 9.2 08/31/2005 22:20:00 7.6 0.6 9.5 6.1 7.6 0.7 9.5 5.3 194 4 198 305 9.2 0 9.5 9.2 08/31/2005 22:30:00 8 0.6 9.1 6.1 7.9 0.7 9.5 5.7 195 4 194 305 9.3 0 9.5 9.2 08/31/2005 22:40:00 7.7 0.6 8.8 6.1 7.6 0.6 9.1 5.7 196 4 197 305 9.2 0 9.5 9.2 08/31/2005 22:50:00 7.6 0.6 9.1 5.7 7.6 0.6 9.1 5.3 195 4 194 305 9.3 0 9.5 9.2 08/31/2005 23:00:00 7.6 0.5 8.8 6.1 7.6 0.6 9.1 5.3 193 4 198 305 9.3 0 9.5 9.2 08/31/2005 23:10:00 8 0.7 9.1 6.1 7.9 0.7 9.1 5.7 195 5 205 305 9.3 0 9.5 9.2 08/31/2005 23:20:00 7.8 0.5 9.1 6.1 7.8 0.6 9.1 5.7 197 3 188 305 9.2 0 9.5 9.2 08/31/2005 23:30:00 7.4 0.6 8.8 5.7 7.3 0.7 9.1 5.3 196 4 188 305 9.1 0 9.2 8.9 08/31/2005 23:40:00 7.5 0.5 9.1 6.1 7.4 0.5 8.8 5.7 196 4 198 305 9.1 0 9.2 8.9 08/31/2005 23:50:00 7.7 0.5 8.8 6.1 7.5 0.5 8.8 6.1 195 4 202 305 9.1 0 9.2 9.2 09/01/2005 00:00:00 7.5 0.5 8.8 5.7 7.3 0.6 8.8 5.3 197 4 198 305 9.1 0 9.7 8.9 09/01/2005 00:10:00 7 0.4 8 5.3 7 0.5 8.4 5.3 197 4 196 305 8.9 0 9.2 8.9 09/01/2005 00:20:00 6.8 0.6 8 5.3 6.7 0.6 8.4 4.9 195 4 200 305 8.9 0 9.2 8.9 09/01/2005 00:30:00 7.2 0.5 8.8 5.3 7.3 0.6 9.1 5.7 196 4 201 305 9 0 9.2 8.9 09/01/2005 00:40:00 7.7 0.5 9.1 6.1 7.5 0.6 8.8 5.7 197 3 196 305 9 0 9.2 8.9 09/01/2005 00:50:00 7.8 0.5 8.8 6.5 7.7 0.6 8.8 5.7 197 4 199 305 9.1 0 9.5 8.9 09/01/2005 01:00:00 8 0.4 9.1 6.5 7.9 0.5 9.1 5.7 198 4 196 305 9.1 0 9.2 8.9 09/01/2005 01:10:00 7.7 0.5 9.1 6.5 7.7 0.6 8.8 5.7 197 4 194 305 9 0 9.2 8.9 09/01/2005 01:20:00 7.7 0.5 9.1 6.5 7.7 0.6 9.1 6.1 196 4 192 305 8.9 0 9.2 8.9 09/01/2005 01:30:00 8 0.6 9.1 6.1 8 0.6 9.1 5.7 198 4 198 305 8.9 0 9.2 8.9 09/01/2005 01:40:00 8 0.5 9.1 6.5 8 0.5 9.1 6.1 199 3 200 305 8.9 0 9.2 8.9 09/01/2005 01:50:00 7.8 0.5 9.5 6.1 7.7 0.5 9.1 6.1 197 4 196 305 8.9 0 9.2 8.9 09/01/2005 02:00:00 7.6 0.5 8.8 6.1 7.6 0.6 9.1 5.3 199 5 200 305 8.8 0 9.2 8.7 09/01/2005 02:10:00 6.9 0.4 8 5.7 7.1 0.5 8.4 5.3 202 4 201 305 8.9 0 9.2 8.9 09/01/2005 02:20:00 6.3 0.5 7.6 5.3 6.5 0.5 8.4 4.9 203 5 208 305 8.9 0 9.2 8.9 09/01/2005 02:30:00 6.2 0.5 7.6 4.6 6.2 0.5 7.2 4.6 210 5 211 305 9.1 0 9.5 8.9 09/01/2005 02:40:00 6.5 0.6 7.6 4.6 6.5 0.6 8 4.9 209 4 208 305 9.3 0 9.5 9.2 09/01/2005 02:50:00 6 0.4 6.8 4.6 6.1 0.4 7.2 4.9 204 6 208 305 9.1 0 9.2 8.9 09/01/2005 03:00:00 6 0.4 7.6 4.6 6.1 0.5 7.6 4.6 202 6 207 305 9 0 9.2 8.9 09/01/2005 03:10:00 5.6 0.6 7.6 4.2 5.7 0.5 6.8 4.2 208 6 198 305 9.1 0 9.5 8.9 09/01/2005 03:20:00 5.6 0.6 6.8 4.2 5.5 0.7 7.2 3.8 211 6 205 305 9.1 0 9.5 8.9 09/01/2005 03:30:00 5.3 0.6 6.8 3.8 5.3 0.6 6.5 3.8 211 7 224 305 9.1 0 9.7 8.9 09/01/2005 03:40:00 6.6 0.7 8 4.6 6.4 0.8 8 3.8 216 6 216 305 9.3 0.1 9.7 8.9 09/01/2005 03:50:00 6.1 0.6 7.2 4.2 6 0.6 7.2 4.2 210 5 210 305 9.3 0 9.7 9.2 09/01/2005 04:00:00 5.7 0.5 7.2 4.6 5.7 0.5 6.8 3.8 198 5 210 305 9 0 9.5 8.9 09/01/2005 04:10:00 6.1 0.4 7.2 4.9 6.1 0.4 6.8 4.9 197 4 205 305 8.8 0 8.9 8.7 09/01/2005 04:20:00 6.3 0.4 7.2 4.6 6.4 0.5 7.6 4.9 193 5 196 305 8.7 0 8.9 8.7 09/01/2005 04:30:00 6.2 0.4 7.6 4.9 6.3 0.5 7.2 5.3 193 4 188 305 8.8 0 8.9 8.7 09/01/2005 04:40:00 5.9 0.4 6.8 4.6 5.9 0.5 7.2 4.2 194 4 189 305 8.7 0 9.2 8.4 09/01/2005 04:50:00 6 0.4 7.2 4.9 6.1 0.5 7.2 4.9 193 5 198 305 8.8 0.1 9.2 8.7 09/01/2005 05:00:00 5.9 0.5 7.6 4.6 6.2 0.6 7.6 4.6 191 6 197 305 8.9 0 9.2 8.9 09/01/2005 05:10:00 5.7 0.5 7.2 4.2 6.1 0.6 7.6 4.2 190 5 192 305 8.9 0 9.2 8.9 09/01/2005 05:20:00 5.8 0.5 7.2 4.2 5.9 0.6 7.6 4.2 193 5 196 305 8.8 0 9.2 8.7 09/01/2005 05:30:00 6.3 0.5 7.6 5.3 6.4 0.5 7.6 4.9 193 4 192 305 8.8 0 9.2 8.7 09/01/2005 05:40:00 6.2 0.4 7.6 4.6 6.3 0.5 7.6 4.6 193 3 197 305 8.7 0 8.9 8.7 09/01/2005 05:50:00 6.5 0.4 7.6 4.9 6.5 0.5 7.6 4.9 193 3 196 305 8.8 0 8.9 8.7 09/01/2005 06:00:00 7.1 0.5 8.4 5.7 7.1 0.5 8.4 5.3 195 3 196 305 8.8 0 9.2 8.7 09/01/2005 06:10:00 7.2 0.5 8 5.3 7.1 0.5 8.4 5.3 194 3 192 305 9.1 0 9.2 8.9 09/01/2005 06:20:00 6.8 0.5 8 5.3 6.8 0.6 8 4.9 194 4 195 305 9.2 0 9.5 8.9 09/01/2005 06:30:00 6.5 0.5 7.6 4.9 6.5 0.5 7.6 4.9 194 5 197 305 9.2 0 9.7 9.2 09/01/2005 06:40:00 6.6 0.6 8 4.9 6.5 0.6 8 4.9 195 4 196 305 9.2 0 9.7 9.2 09/01/2005 06:50:00 7 0.5 8.4 5.3 7 0.5 8 4.9 195 4 202 305 9.2 0 9.7 9.2 09/01/2005 07:00:00 7.3 0.6 8.8 5.7 7.1 0.6 8.4 4.9 195 3 200 305 9.2 0 9.5 9.2 09/01/2005 07:10:00 6.8 0.5 8 5.3 6.8 0.6 8.4 4.9 194 4 195 305 9.2 0 9.7 9.2 09/01/2005 07:20:00 6.5 0.5 8 4.9 6.4 0.6 8.4 4.9 194 4 198 305 9.3 0 9.7 9.2 09/01/2005 07:30:00 6.6 0.5 8 4.9 6.6 0.6 7.6 4.9 193 4 191 305 9.3 0.1 9.7 9.2 09/01/2005 07:40:00 6.2 0.5 7.6 4.9 6.3 0.6 7.6 4.2 193 4 203 305 9.3 0.1 9.7 9.2 09/01/2005 07:50:00 6.2 0.5 7.2 4.2 6.3 0.6 7.6 3.8 193 4 193 305 9.3 0.1 9.7 9.2 09/01/2005 08:00:00 6.3 0.5 8 4.2 6.4 0.5 7.6 4.2 192 4 193 305 9.3 0 9.5 9.2 09/01/2005 08:10:00 6.2 0.5 7.2 4.6 6.2 0.6 7.6 4.2 193 4 189 305 9.4 0 9.5 9.2 09/01/2005 08:20:00 6.1 0.5 7.2 4.6 6.2 0.6 7.2 4.6 192 4 198 305 9.5 0 9.7 9.5 09/01/2005 08:30:00 6 0.4 6.8 4.6 6.1 0.5 7.2 4.6 191 4 192 305 9.5 0 9.7 9.5 09/01/2005 08:40:00 5.8 0.5 7.6 4.6 5.9 0.5 7.2 4.2 189 4 190 305 9.7 0 9.7 9.5 09/01/2005 08:50:00 5.2 0.5 6.5 3.8 5.6 0.5 6.8 3.8 188 4 188 305 9.7 0 10 9.7 09/01/2005 09:00:00 4.9 0.5 6.5 3.8 5.1 0.5 6.5 3.8 188 4 196 305 9.9 0 10 9.7 09/01/2005 09:10:00 5.2 0.4 6.8 4.2 5.4 0.4 6.8 4.2 190 4 197 305 9.9 0 10 9.7 09/01/2005 09:20:00 5 0.5 6.5 3.8 5.2 0.5 6.5 3.8 190 4 190 305 10 0 10.2 10 09/01/2005 09:30:00 4.8 0.5 6.1 3.8 5.1 0.5 6.1 3.8 188 4 192 305 10.2 0 10.2 10 09/01/2005 09:40:00 4.7 0.5 6.1 3 5.3 0.5 6.5 3.8 186 4 183 305 10.2 0 10.2 10.2 09/01/2005 09:50:00 4.9 0.5 6.1 3.4 5.3 0.5 6.5 3.8 186 4 189 305 10.3 0 10.5 10.2 09/01/2005 10:00:00 4.7 0.6 6.1 3 4.9 0.6 6.5 3.4 191 5 195 305 10.3 0 10.5 10.2 09/01/2005 10:10:00 5.5 0.4 6.5 4.6 5.6 0.4 6.5 4.6 193 4 190 305 10.2 0 10.2 10.2 09/01/2005 10:20:00 4.5 0.8 6.1 2.3 4.9 0.6 6.1 3 188 6 192 305 10.2 0 10.2 10 09/01/2005 10:30:00 3.9 1 5.7 1.9 4.6 0.6 6.1 3 183 6 184 305 10.3 0 10.2 10.2 09/01/2005 10:40:00 3.9 0.8 5.3 1.9 4.6 0.5 5.7 3.4 176 12 188 305 10.2 0 10.5 10 09/01/2005 10:50:00 4.3 0.7 6.1 2.3 4.6 0.5 5.7 3 153 6 152 305 9.9 0 10.2 9.7 09/01/2005 11:00:00 5.4 0.7 7.2 3.8 5.5 0.6 7.2 3.8 148 5 143 305 9.8 0 10 9.7 09/01/2005 11:10:00 6.1 0.5 7.2 4.6 6.1 0.5 7.2 4.6 146 4 140 305 9.7 0 10 9.7 09/01/2005 11:20:00 6.5 0.4 7.2 5.3 6.5 0.5 7.6 4.9 145 4 142 305 9.7 0 9.7 9.7 09/01/2005 11:30:00 6.8 0.6 8.4 5.3 6.7 0.6 8 4.9 144 4 148 305 9.7 0 9.7 9.7 09/01/2005 11:40:00 7.3 0.7 8.8 5.7 7.2 0.7 8.8 5.3 142 4 142 305 9.8 0 10 9.7 09/01/2005 11:50:00 7.8 0.6 9.5 5.7 7.7 0.6 9.1 6.1 142 5 143 305 9.9 0 10 9.7 09/01/2005 12:00:00 7.8 0.7 9.1 5.3 7.7 0.7 9.1 6.1 143 5 149 305 9.9 0 10 9.7 09/01/2005 12:10:00 7.2 1 9.1 4.9 7.2 0.9 9.1 4.6 146 7 148 305 9.9 0 10 9.7 09/01/2005 12:20:00 6.9 0.9 8.8 4.9 6.9 0.7 8.4 4.9 148 7 143 305 9.9 0 10 9.7 09/01/2005 12:30:00 6.7 1 9.1 3.4 6.8 0.9 8.8 4.6 151 7 147 305 9.8 0 10 9.7 09/01/2005 12:40:00 6.5 1.3 8.8 3 6.8 0.9 9.1 4.2 154 8 155 305 9.8 0 10 9.7 09/01/2005 12:50:00 6.4 1.1 8.8 3.4 6.9 0.7 9.1 4.6 156 8 158 305 9.8 0 10 9.7 09/01/2005 13:00:00 5.4 1 8 2.6 6.3 0.7 8.8 4.2 158 8 146 305 9.9 0 10 9.7 09/01/2005 13:10:00 5.2 1.2 8.8 2.6 6.1 0.8 8 3.8 160 9 154 305 9.9 0 10 9.7 09/01/2005 13:20:00 5.3 1.2 8 2.3 5.8 0.8 8 3.8 158 9 156 305 9.8 0 10 9.7 09/01/2005 13:30:00 6 1.2 9.1 3.4 6.4 0.8 8.8 4.6 156 9 154 305 9.7 0 9.7 9.7 09/01/2005 13:40:00 6.8 0.9 8.8 4.2 6.7 0.6 8.4 4.9 151 6 151 305 9.6 0 9.7 9.5 09/01/2005 13:50:00 6.6 0.9 8.8 4.6 6.5 0.8 8.4 4.6 149 6 152 305 9.5 0 9.7 9.2 09/01/2005 14:00:00 6.9 0.9 8.8 3.8 6.8 0.8 8.8 4.6 149 6 152 305 9.5 0 9.7 9.2 09/01/2005 14:10:00 6.3 0.9 8.4 3.8 6.4 0.7 8.4 4.6 148 7 137 305 9.3 0 9.5 9.2 09/01/2005 14:20:00 6.6 1 8.8 4.2 6.6 0.9 8.8 4.6 143 9 130 305 9.3 0 9.5 9.2 09/01/2005 14:30:00 7.7 0.7 9.1 5.7 7.7 0.7 9.1 5.3 138 5 137 305 9.2 0 9.5 9.2 09/01/2005 14:40:00 7.3 0.9 9.9 4.9 7.2 0.8 9.1 4.9 140 6 136 305 9.2 0 9.2 9.2 09/01/2005 14:50:00 5.9 0.9 8.4 3.8 6 0.9 8.4 3.8 144 9 156 305 9.2 0 9.7 9.2 09/01/2005 15:00:00 6 0.8 8 4.2 5.9 0.8 7.6 4.2 139 9 133 305 9.2 0 9.7 9.2 09/01/2005 15:10:00 6.2 0.8 8.4 4.2 6.3 0.7 8.4 4.6 140 9 144 305 9.2 0 9.7 9.2 09/01/2005 15:20:00 7 0.7 8.4 5.3 6.9 0.6 8.4 5.3 134 5 128 305 9.2 0 9.7 9.2 09/01/2005 15:30:00 7.3 0.7 8.8 5.3 7.2 0.7 8.4 5.3 135 5 137 305 9.2 0 9.7 9.2 09/01/2005 15:40:00 7.6 0.7 9.1 5.7 7.5 0.7 9.1 5.7 135 5 136 305 9.1 0 9.7 8.9 09/01/2005 15:50:00 7.4 0.7 9.1 5.3 7.3 0.7 9.1 5.7 137 6 139 305 9.1 0 9.7 8.9 09/01/2005 16:00:00 7.6 0.7 9.5 5.3 7.5 0.7 9.1 4.9 137 6 140 305 9.1 0 9.5 8.9 09/01/2005 16:10:00 7.1 0.8 8.8 5.3 7.2 0.8 9.1 5.3 139 8 133 305 9 0 9.5 8.9 09/01/2005 16:20:00 6.6 1 9.5 4.6 6.6 1 9.1 4.6 138 9 138 305 9 0 9.5 8.9 09/01/2005 16:30:00 7.4 1 9.9 4.2 7.2 1.1 9.9 4.6 138 8 138 305 9 0 9.5 8.9 09/01/2005 16:40:00 8.2 0.9 9.9 4.9 8.1 0.8 9.9 5.7 139 6 141 305 9.1 0 9.5 8.9 09/01/2005 16:50:00 8.7 0.7 11.1 6.5 8.5 0.7 10.3 6.5 139 6 137 305 9.1 0 9.7 9.2 09/01/2005 17:00:00 7.8 0.7 9.9 5.7 7.7 0.7 9.5 5.7 137 6 158 305 9.2 0 9.7 9.2 09/01/2005 17:10:00 7.2 0.6 8.4 5.3 7.1 0.7 8.8 4.6 134 5 122 305 9.2 0 9.7 8.9 09/01/2005 17:20:00 7.9 0.6 9.5 5.7 7.8 0.6 9.1 5.7 134 5 121 305 9.1 0 9.7 8.9 09/01/2005 17:30:00 8.1 0.6 9.5 6.1 8 0.6 9.5 5.7 135 5 142 305 9.1 0 9.7 8.9 09/01/2005 17:40:00 7.8 0.8 9.1 5.7 7.7 0.7 9.1 5.7 134 6 130 305 9 0 9.7 8.9 09/01/2005 17:50:00 7.5 1 10.3 4.9 7.4 1 9.5 4.6 133 8 136 305 9 0 9.5 8.9 09/01/2005 18:00:00 6.3 1 9.5 4.2 6.2 1.1 9.1 3.4 126 15 118 305 9 0 9.2 8.9 09/01/2005 18:10:00 6.8 1.2 10.3 3.4 6.8 1.2 10.3 3.8 122 12 127 305 8.9 0 9.2 8.9 09/01/2005 18:20:00 6.5 1.1 9.5 3.4 6.4 1.1 9.5 3 124 12 119 305 8.9 0 9.5 8.9 09/01/2005 18:30:00 5.6 1.3 9.1 3 5.7 1.3 8.8 2.3 126 14 115 305 8.9 0 9.5 8.9 09/01/2005 18:40:00 5 1.3 8.4 2.3 4.9 1.2 8 2.6 129 14 133 305 8.9 0 9.5 8.9 09/01/2005 18:50:00 5 1.2 7.2 1.9 4.9 1.2 7.2 1.5 123 15 113 305 8.9 0.1 9.5 8.9 09/01/2005 19:00:00 5.2 1.2 8 1.9 5.1 1.2 8 2.6 128 17 143 305 8.9 0 9.2 8.7 09/01/2005 19:10:00 5.2 0.9 7.6 3 5.1 0.8 7.2 3 125 12 129 305 8.9 0 9.2 8.7 09/01/2005 19:20:00 5.4 1.2 8.8 2.6 5.4 1.1 8 2.6 124 15 98 305 8.9 0 9.2 8.7 09/01/2005 19:30:00 5.3 1.2 9.1 3 5.4 1.1 8.8 3 124 15 123 305 8.9 0 9.2 8.9 09/01/2005 19:40:00 5 1.2 8.4 2.6 4.9 1.1 8.8 2.6 126 16 116 305 8.9 0 9.2 8.9 09/01/2005 19:50:00 3.8 1.3 7.6 1.1 3.9 1.2 7.2 1.5 128 22 121 305 8.9 0 9.2 8.7 09/01/2005 20:00:00 4.8 1.5 8.4 1.1 4.8 1.3 8 2.3 128 21 130 305 8.8 0.1 9.2 8.7 09/01/2005 20:10:00 4.3 1.3 8.4 1.5 4.3 1.3 8 1.5 131 20 144 305 8.8 0.1 9.2 8.7 09/01/2005 20:20:00 1.3 1 4.2 0.4 1.6 0.9 3.8 0.4 87 51 33 305 8.8 0.1 9.2 8.7 09/01/2005 20:30:00 1.6 1.3 5.7 0.4 1.8 1.1 4.9 0.4 121 35 89 305 8.8 0.1 9.2 8.7 09/01/2005 20:40:00 2.2 1.3 5.3 0.4 2.1 1.1 5.7 0.4 118 43 168 305 8.8 0 8.9 8.7 09/01/2005 20:50:00 2.7 1.4 6.1 0.4 2.9 1.2 5.7 0.4 97 39 61 305 8.8 0 8.9 8.7 09/01/2005 21:00:00 4 1.3 8.4 1.5 4 1.5 7.2 0.7 102 30 123 305 8.8 0 8.9 8.7 09/01/2005 21:10:00 3.3 1.5 8 0.7 3.3 1.2 7.6 0.7 99 36 72 305 8.8 0 8.9 8.7 09/01/2005 21:20:00 2.7 1.6 6.8 0.4 3 1.5 7.6 0.4 88 38 143 305 8.8 0 8.9 8.7 09/01/2005 21:30:00 3.1 1.5 6.8 0.4 3.2 1.3 7.2 1.1 102 24 101 305 8.7 0 8.9 8.7 09/01/2005 21:40:00 2.8 1.3 6.1 0.4 2.9 1.1 6.1 0.4 79 32 76 305 8.7 0 8.9 8.7 09/01/2005 21:50:00 2.3 1 4.2 0.4 2.6 0.8 4.6 0.4 72 22 54 305 8.7 0 8.9 8.7 09/01/2005 22:00:00 3.3 1.5 6.8 0.4 3.5 1.4 6.5 0.7 75 32 56 305 8.7 0 8.9 8.7 09/01/2005 22:10:00 4.6 1.2 8.4 1.5 4.6 1.2 8.4 1.9 63 16 64 305 8.6 0 8.7 8.4 09/01/2005 22:20:00 5.5 1.6 9.1 2.3 5.5 1.5 9.1 1.9 60 13 51 305 8.6 0 8.7 8.4 09/01/2005 22:30:00 6.8 0.9 9.9 4.9 6.6 1 9.9 4.2 63 8 75 305 8.6 0 8.7 8.4 09/01/2005 22:40:00 7.4 1.1 10.7 4.2 7.2 1.1 10.7 4.2 66 8 68 305 8.6 0 8.7 8.4 09/01/2005 22:50:00 8.4 0.9 10.7 5.7 8.3 1 11.1 6.1 65 7 62 305 8.6 0 8.9 8.4 09/01/2005 23:00:00 8.6 0.7 10.7 5.7 8.4 0.7 10.7 6.5 68 5 72 305 8.7 0 9.2 8.4 09/01/2005 23:10:00 8.4 0.7 11.1 6.5 8.2 0.7 10.3 6.5 69 5 76 305 8.7 0 8.9 8.4 09/01/2005 23:20:00 8.2 0.6 9.5 5.7 7.9 0.6 9.5 5.3 71 6 81 305 8.7 0 8.9 8.7 09/01/2005 23:30:00 8.2 0.6 9.9 6.1 7.8 0.6 9.1 6.1 72 4 73 305 8.7 0 9.2 8.7 09/01/2005 23:40:00 8.3 0.5 9.5 6.5 8.1 0.5 9.1 6.8 72 4 76 305 8.7 0 8.9 8.7 09/01/2005 23:50:00 8.3 0.6 9.5 6.5 8 0.6 9.5 5.7 70 5 72 305 8.7 0 8.9 8.4 09/02/2005 00:00:00 8.8 0.6 10.7 6.8 8.6 0.6 10.3 6.8 70 4 71 305 8.6 0 8.9 8.4 09/02/2005 00:10:00 8.9 0.5 10.3 7.2 8.6 0.6 9.9 6.8 70 4 67 305 8.6 0 8.9 8.7 09/02/2005 00:20:00 9.3 0.6 10.7 7.6 9 0.5 10.3 7.2 72 4 76 305 8.7 0 8.9 8.4 09/02/2005 00:30:00 9.8 0.6 11.1 8.4 9.5 0.6 10.7 7.6 73 4 71 305 8.7 0 9.2 8.7 09/02/2005 00:40:00 9.9 0.6 11.1 8 9.4 0.6 11.1 7.2 74 4 75 305 8.7 0 8.9 8.7 09/02/2005 00:50:00 9.9 0.7 11.5 7.6 9.6 0.7 11.1 7.2 75 5 73 305 8.8 0 9.2 8.7 09/02/2005 01:00:00 10 0.7 11.1 7.2 9.5 0.7 11.1 7.2 77 5 66 305 8.8 0 8.9 8.7 09/02/2005 01:10:00 10 0.8 11.8 8 9.5 0.8 11.8 7.6 76 5 81 305 8.8 0 8.9 8.7 09/02/2005 01:20:00 9.9 0.7 11.8 7.6 9.5 0.7 12.2 7.2 75 5 80 305 8.8 0 8.9 8.9 09/02/2005 01:30:00 9.9 0.7 11.8 8 9.5 0.7 11.5 7.2 71 5 68 305 8.8 0 8.9 8.9 09/02/2005 01:40:00 9.9 0.7 11.8 8 9.5 0.8 11.8 7.6 72 5 71 305 8.8 0 8.9 8.9 09/02/2005 01:50:00 10.6 0.7 12.2 9.1 10.2 0.6 12.2 8.4 72 4 73 305 8.8 0 8.9 8.7 09/02/2005 02:00:00 10.7 0.6 12.2 8.8 10.3 0.7 11.8 8 73 4 64 305 8.8 0 8.9 8.9 09/02/2005 02:10:00 11.3 0.6 13 9.5 11 0.7 13 9.1 73 4 69 305 8.8 0 8.9 8.9 09/02/2005 02:20:00 11.2 0.6 13 9.5 10.9 0.7 13.3 8.8 73 4 76 305 8.8 0 8.9 8.9 09/02/2005 02:30:00 11.9 0.6 13.7 10.3 11.5 0.7 13.3 9.1 72 4 70 305 8.8 0 8.9 8.9 09/02/2005 02:40:00 11.7 0.7 13.3 9.9 11.4 0.8 13 9.1 73 4 74 305 8.9 0 9.2 8.9 09/02/2005 02:50:00 11.5 0.6 13 9.5 11.2 0.7 13 9.1 71 4 78 305 8.9 0 8.9 8.9 09/02/2005 03:00:00 11.2 0.6 13 9.1 10.8 0.6 12.6 9.1 71 3 71 305 8.8 0 9.2 8.9 09/02/2005 03:10:00 11.1 0.6 12.6 9.5 10.6 0.6 11.8 8.4 72 4 72 305 8.8 0 9.2 8.9 09/02/2005 03:20:00 11.1 0.5 12.2 9.5 10.5 0.5 11.8 9.1 69 2 71 305 8.8 0 9.2 8.7 09/02/2005 03:30:00 10.2 0.5 11.5 9.1 9.7 0.6 11.1 7.6 69 3 68 305 8.8 0 9.2 8.7 09/02/2005 03:40:00 10 0.5 11.1 8.4 9.5 0.6 10.7 7.6 69 3 72 305 8.7 0 9.2 8.7 09/02/2005 03:50:00 9.8 0.4 11.1 8.4 9.3 0.5 10.3 8.4 67 3 65 305 8.7 0 9.2 8.4 09/02/2005 04:00:00 9.5 0.6 10.7 7.6 9 0.6 10.7 7.2 66 3 69 305 8.6 0 8.7 8.4 09/02/2005 04:10:00 9.1 0.6 10.7 7.2 8.7 0.7 10.3 6.5 65 4 70 305 8.5 0 8.7 8.4 09/02/2005 04:20:00 8.3 0.7 9.9 6.5 7.9 0.7 9.9 6.5 64 5 75 305 8.4 0 8.7 8.4 09/02/2005 04:30:00 9.5 0.6 11.5 7.6 9 0.6 10.7 6.8 65 3 67 305 8.4 0 8.9 8.4 09/02/2005 04:40:00 9.6 0.6 10.7 8 9.2 0.6 10.7 7.6 65 4 67 305 8.4 0 8.7 8.4 09/02/2005 04:50:00 9.5 0.6 11.1 8 9.2 0.5 10.3 8 65 3 63 305 8.4 0 8.7 8.4 09/02/2005 05:00:00 9.6 0.5 11.1 8 9.2 0.5 10.7 7.6 64 4 62 305 8.4 0 8.9 8.4 09/02/2005 05:10:00 8.9 0.6 10.7 7.2 8.6 0.7 10.3 6.5 62 4 59 305 8.4 0 8.9 8.2 09/02/2005 05:20:00 8.9 0.5 9.9 7.2 8.4 0.5 9.9 7.2 59 3 60 305 8.3 0 8.7 8.2 09/02/2005 05:30:00 9 0.4 10.3 8 8.5 0.5 9.9 7.2 57 3 57 305 8.4 0 8.9 8.2 09/02/2005 05:40:00 8.9 0.5 10.3 7.6 8.6 0.5 9.9 7.2 57 3 56 305 8.4 0 8.7 8.2 09/02/2005 05:50:00 9.6 0.5 11.1 8.4 9.1 0.5 10.7 7.6 57 3 57 305 8.3 0 8.4 8.2 09/02/2005 06:00:00 9.8 0.5 10.7 8 9.4 0.5 11.1 8 58 3 56 305 8.3 0 8.4 8.2 09/02/2005 06:10:00 9.9 0.5 11.5 8.4 9.3 0.6 11.1 7.6 59 4 57 305 8.3 0 8.4 8.2 09/02/2005 06:20:00 9.7 0.6 11.1 8 9.2 0.6 11.1 7.6 59 4 56 305 8.2 0 8.4 8.2 09/02/2005 06:30:00 9.7 0.5 11.1 8 9.2 0.6 10.7 7.2 60 3 57 305 8.2 0 8.4 8.2 09/02/2005 06:40:00 9.9 0.6 11.8 8.4 9.4 0.6 11.5 7.6 60 3 60 305 8.3 0 8.4 8.2 09/02/2005 06:50:00 9.9 0.5 11.5 8.4 9.4 0.6 11.1 8 59 3 59 305 8.3 0 8.4 8.2 09/02/2005 07:00:00 10 0.6 11.8 8.4 9.6 0.6 11.5 7.6 57 3 57 305 8.3 0 8.4 8.2 09/02/2005 07:10:00 10.3 0.5 11.8 8.8 9.9 0.6 11.5 7.6 54 3 53 305 8.3 0 8.4 8.2 09/02/2005 07:20:00 10.8 0.5 12.2 9.5 10.4 0.6 11.8 9.1 50 3 50 305 8.3 0 8.4 8.2 09/02/2005 07:30:00 10.9 0.5 12.2 9.5 10.5 0.6 11.8 8.8 48 3 45 305 8.3 0 8.4 8.2 09/02/2005 07:40:00 11.3 0.7 13 9.9 10.9 0.7 12.6 8.8 48 3 51 305 8.2 0 8.4 8.2 09/02/2005 07:50:00 12 0.7 13.7 10.3 11.6 0.7 13 9.5 47 3 44 305 8.2 0 8.4 8.2 09/02/2005 08:00:00 11.8 0.6 14.1 9.9 11.4 0.8 13.3 9.1 46 3 45 305 8.2 0 8.4 8.2 09/02/2005 08:10:00 12.3 0.6 14.1 9.9 11.9 0.7 13.7 9.5 46 3 45 305 8.2 0 8.4 8.2 09/02/2005 08:20:00 12.1 0.7 14.1 9.9 11.7 0.7 13.3 9.5 45 3 46 305 8.2 0 8.4 8.2 09/02/2005 08:30:00 12.3 0.7 14.1 10.7 11.9 0.8 13.7 9.9 45 3 42 305 8.2 0 8.7 8.2 09/02/2005 08:40:00 12.2 0.7 14.5 9.9 11.8 0.8 13.7 9.5 43 3 43 305 8.2 0 8.7 8.2 09/02/2005 08:50:00 12.5 0.6 14.1 10.7 12.1 0.7 14.1 10.3 43 3 42 305 8.2 0 8.4 8.2 09/02/2005 09:00:00 12.4 0.7 14.1 10.3 12.1 0.8 14.1 9.9 42 4 40 305 8.2 0 8.4 7.9 09/02/2005 09:10:00 12.7 0.6 14.5 10.7 12.4 0.8 14.1 10.7 43 4 42 305 8.2 0 8.7 8.2 09/02/2005 09:20:00 12.5 0.8 14.5 10.3 12.1 0.9 14.5 9.5 42 3 42 305 8.2 0 8.4 8.2 09/02/2005 09:30:00 12.9 0.7 14.5 11.5 12.5 0.8 14.5 10.3 42 3 40 305 8.1 0 8.4 8.2 09/02/2005 09:40:00 13.4 0.6 14.9 11.5 13 0.7 14.9 11.1 41 3 37 305 8.1 0 8.4 8.2 09/02/2005 09:50:00 13.5 0.9 15.6 11.5 13.1 1 15.3 10.3 41 3 43 305 8.1 0 8.4 8.2 09/02/2005 10:00:00 13.4 0.8 15.3 10.7 13.1 0.9 15.3 9.9 39 3 44 305 8.1 0 8.4 8.2 09/02/2005 10:10:00 13.2 0.9 15.6 10.7 12.7 1 14.9 9.9 34 4 33 305 7.9 0.2 8.4 7.7 09/02/2005 10:20:00 14.9 0.9 16.8 12.6 14.4 1 16.8 11.1 32 4 29 305 7.5 0 7.7 7.4 09/02/2005 10:30:00 14.8 1 17.2 12.2 14.3 1.1 16.8 11.5 32 3 33 305 7.5 0 7.7 7.4 09/02/2005 10:40:00 15.4 1 17.9 12.2 14.9 1.1 17.6 12.2 33 3 35 305 7.5 0 7.7 7.4 09/02/2005 10:50:00 15.3 1 17.6 12.6 14.8 1 16.8 11.8 34 3 33 305 7.4 0 7.7 7.4 09/02/2005 11:00:00 14.8 1.1 17.2 11.8 14.4 1.2 17.2 11.5 34 3 32 305 7.3 0 7.7 7.4 09/02/2005 11:10:00 15 1.1 17.6 11.8 14.6 1.1 17.2 11.5 33 3 34 305 7.3 0 7.4 7.4 09/02/2005 11:20:00 14.8 0.9 17.2 10.7 14.4 1 16.4 11.1 35 3 37 305 7.3 0 7.4 7.4 09/02/2005 11:30:00 14.6 1 16.4 12.2 14.2 1 16.4 11.1 35 3 33 305 7.4 0 7.7 7.4 09/02/2005 11:40:00 14.2 1 16.8 11.8 13.9 1.1 16.4 11.5 37 4 39 305 7.5 0 7.7 7.4 09/02/2005 11:50:00 14.2 1.1 16.4 11.1 13.7 1.2 16.1 10.3 39 4 44 305 7.7 0 7.9 7.7 09/02/2005 12:00:00 14.6 1 16.8 11.1 14.2 1.1 16.4 10.7 38 3 37 305 7.6 0 7.7 7.7 09/02/2005 12:10:00 14.8 1 17.2 12.2 14.4 1.1 16.8 11.1 38 3 40 305 7.5 0 7.7 7.4 09/02/2005 12:20:00 14 0.9 16.4 11.8 13.7 1 16.1 11.5 40 4 37 305 7.5 0 7.7 7.7 09/02/2005 12:30:00 15 1.2 17.6 11.5 14.5 1.3 17.2 11.1 41 4 39 305 7.6 0 8.2 7.7 09/02/2005 12:40:00 15.2 1.1 17.6 11.8 15 1.2 17.9 11.5 41 4 39 305 7.7 0 8.2 7.7 09/02/2005 12:50:00 15.5 1 17.6 12.6 15.4 1.1 17.9 12.6 39 4 44 305 7.5 0 7.9 7.4 09/02/2005 13:00:00 15.6 1.1 17.9 13.3 15.4 1.3 17.9 12.2 38 3 37 305 7.4 0 7.9 7.4 09/02/2005 13:10:00 15.2 1 17.6 12.6 15 1.1 17.6 12.2 38 4 30 305 7.3 0.1 7.9 7.2 09/02/2005 13:20:00 15.7 1.1 17.9 13 15.5 1.1 17.9 12.6 37 4 41 305 7.2 0.1 7.9 7.2 09/02/2005 13:30:00 15.4 1.1 17.9 12.6 15.2 1.2 18.3 11.8 39 5 39 305 7.1 0.1 7.7 7.2 09/02/2005 13:40:00 15.6 1.1 18.3 13 15.4 1.3 17.9 12.2 38 4 37 305 7.2 0.1 7.7 7.2 09/02/2005 13:50:00 15.6 1.2 18.3 12.6 15.4 1.3 18.7 12.2 39 4 38 305 7.2 0.2 7.7 7.2 09/02/2005 14:00:00 15.8 1.1 18.3 13.3 15.5 1.2 18.3 12.2 38 4 38 305 7.2 0.1 7.7 7.2 09/02/2005 14:10:00 16.2 0.9 18.3 13.7 15.9 1 18.3 13 40 4 40 305 7.2 0.1 7.7 7.2 09/02/2005 14:20:00 15.7 1.2 18.7 11.8 15.5 1.3 19.1 11.8 40 4 41 305 7.2 0.1 7.7 7.2 09/02/2005 14:30:00 16.1 1.2 19.1 12.2 15.9 1.3 19.5 11.8 39 4 36 305 7.2 0.2 7.7 7.2 09/02/2005 14:40:00 15.9 1.2 18.3 13 15.7 1.2 18.3 12.2 40 4 39 305 7.2 0.1 7.7 7.2 09/02/2005 14:50:00 16.2 1.1 18.7 13.3 15.9 1.2 18.7 12.6 39 4 38 305 7.1 0.1 7.7 7.2 09/02/2005 15:00:00 15.3 1.2 17.9 11.8 15.1 1.4 17.9 10.7 39 4 35 305 7.2 0 7.4 7.2 09/02/2005 15:10:00 15.3 1.3 18.3 11.8 15.1 1.5 18.3 11.5 39 4 46 305 7.1 0 7.4 7.2 09/02/2005 15:20:00 15.6 1.1 18.3 11.8 15.4 1.2 17.9 11.8 38 4 40 305 7.1 0 7.4 7.2 09/02/2005 15:30:00 16.8 1.2 19.1 13 16.6 1.2 18.7 12.2 37 4 40 305 7 0 7.4 6.9 09/02/2005 15:40:00 16 1.5 19.5 11.8 15.8 1.6 19.5 11.8 37 4 39 305 7 0 7.2 6.9 09/02/2005 15:50:00 15.9 1.3 19.1 13 15.5 1.5 19.1 12.2 37 4 34 305 7 0 7.4 6.9 09/02/2005 16:00:00 16.3 1.4 19.5 13 16 1.5 18.7 11.8 35 4 32 305 7 0 7.4 6.9 09/02/2005 16:10:00 17 1.1 19.5 13.3 16.7 1.2 19.1 13.3 36 4 35 305 6.8 0 7.2 6.9 09/02/2005 16:20:00 16.3 1.5 19.9 12.2 16.1 1.5 19.5 13 36 5 38 305 6.8 0 7.2 6.7 09/02/2005 16:30:00 16.5 1.4 19.5 12.6 16.2 1.5 19.5 11.5 37 4 37 305 6.8 0 7.2 6.7 09/02/2005 16:40:00 17 1.3 19.9 12.6 16.6 1.5 19.9 13 37 4 33 305 6.7 0 7.2 6.7 09/02/2005 16:50:00 16.9 1.3 19.5 13.3 16.5 1.3 19.9 13.3 36 4 35 305 6.7 0 7.2 6.4 09/02/2005 17:00:00 16.6 1.5 19.5 13 16.4 1.5 19.1 11.8 36 5 38 305 6.7 0 7.2 6.4 09/02/2005 17:10:00 16.5 1.3 19.1 13 16.4 1.3 19.1 12.6 37 4 37 305 6.6 0.1 7.2 6.4 09/02/2005 17:20:00 16.6 1.3 20.2 13 16.4 1.4 20.2 12.2 37 5 34 305 6.6 0 7.2 6.4 09/02/2005 17:30:00 16.6 1.1 19.5 13 16.3 1.1 18.7 13 38 5 35 305 6.5 0 7.2 6.4 09/02/2005 17:40:00 16.6 1.1 19.1 13.3 16.3 1.2 18.7 12.6 39 4 46 305 6.5 0 7.2 6.4 09/02/2005 17:50:00 15.6 1.5 18.7 11.5 15.3 1.6 18.3 11.1 39 5 43 305 6.6 0.1 7.2 6.4 09/02/2005 18:00:00 16.2 1.6 19.5 11.8 16 1.7 19.1 11.8 40 4 37 305 6.5 0 7.2 6.4 09/02/2005 18:10:00 15.8 1.1 17.9 13 15.6 1.2 18.3 12.2 37 4 39 305 6.5 0 6.9 6.4 09/02/2005 18:20:00 16.1 1.4 19.1 12.2 15.8 1.5 19.1 11.8 40 5 44 305 6.5 0 7.2 6.4 09/02/2005 18:30:00 15.3 1.1 17.9 12.6 15 1.3 17.9 10.7 42 5 47 305 6.5 0 7.2 6.4 09/02/2005 18:40:00 14.9 1.1 17.6 12.2 14.8 1.2 17.9 11.5 42 5 37 305 6.5 0 6.9 6.4 09/02/2005 18:50:00 14.9 1.3 17.9 11.5 14.6 1.4 17.9 11.5 40 5 41 305 6.5 0 7.2 6.4 09/02/2005 19:00:00 14.3 1.3 17.6 11.1 14.1 1.3 17.6 11.1 37 5 44 305 6.5 0 7.2 6.4 09/02/2005 19:10:00 15.7 1.2 17.9 11.1 15.4 1.3 17.9 10.7 35 4 32 305 6.3 0.1 7.2 6.1 09/02/2005 19:20:00 15 1.2 17.9 12.2 14.8 1.3 17.9 11.5 38 5 36 305 6.4 0 6.9 6.1 09/02/2005 19:30:00 14.5 1 16.8 11.8 14.2 1.1 16.8 11.1 35 5 41 305 6.5 0 7.2 6.1 09/02/2005 19:40:00 15.8 1.1 18.3 12.6 15.7 1.1 18.7 12.2 34 4 41 305 6.3 0 6.9 6.1 09/02/2005 19:50:00 14.9 1.3 18.3 11.5 14.6 1.4 18.3 11.5 35 5 35 305 6.5 0 7.2 6.1 09/02/2005 20:00:00 15.1 1.2 17.2 12.2 14.7 1.3 17.6 11.5 33 5 33 305 6.3 0 6.4 6.1 09/02/2005 20:10:00 15.4 1.4 17.9 11.8 15.3 1.5 17.9 11.5 33 4 33 305 6.2 0 6.4 6.1 09/02/2005 20:20:00 15.7 1 17.6 12.2 15.4 1.1 17.9 11.1 32 4 36 305 6.1 0 6.4 6.1 09/02/2005 20:30:00 15.2 1.2 17.9 10.3 15.1 1.2 17.6 9.9 36 5 39 305 6.2 0 6.4 6.1 09/02/2005 20:40:00 15.7 1.2 17.9 12.6 15.4 1.2 17.9 12.2 35 5 35 305 6.2 0 6.4 6.1 09/02/2005 20:50:00 16.7 1 19.1 13 16.5 1.1 18.7 13 33 4 33 305 6.1 0 6.4 5.9 09/02/2005 21:00:00 15.7 1.3 18.7 11.5 15.5 1.3 18.7 11.1 32 4 32 305 6.1 0.1 6.4 5.9 09/02/2005 21:10:00 15.8 1.2 17.9 12.2 15.5 1.2 17.9 11.8 32 4 30 305 6 0 6.4 5.9 09/02/2005 21:20:00 15.5 1.2 17.9 11.5 15.4 1.2 17.6 11.5 30 4 34 305 5.8 0 5.9 5.6 09/02/2005 21:30:00 15.5 1 17.6 12.2 15.2 1.2 17.6 12.2 29 4 27 305 5.5 0.1 5.9 5.4 09/02/2005 21:40:00 14.7 1.3 17.6 11.5 14.4 1.3 17.6 10.7 29 4 28 305 5.4 0 5.6 5.4 09/02/2005 21:50:00 15.7 1.2 17.9 12.6 15.5 1.3 19.1 12.2 27 4 27 305 5.4 0 5.6 5.4 09/02/2005 22:00:00 15.4 1 17.6 11.8 15.2 1.2 17.6 11.5 28 5 24 305 5.5 0 5.6 5.4 09/02/2005 22:10:00 15.7 1 18.3 13 15.5 1.1 17.9 12.6 28 4 33 305 5.5 0 5.6 5.4 09/02/2005 22:20:00 15.9 0.8 17.6 13.3 15.7 1 17.9 13 28 4 24 305 5.5 0 5.6 5.4 09/02/2005 22:30:00 15.5 1.1 17.6 11.8 15.2 1.1 17.9 11.5 28 4 27 305 5.5 0 5.6 5.4 09/02/2005 22:40:00 15.6 1.2 18.3 11.8 15.4 1.3 18.3 10.7 28 4 26 305 5.5 0 5.6 5.4 09/02/2005 22:50:00 15.8 1.1 18.3 13 15.5 1.2 18.7 12.6 29 4 24 305 5.4 0 5.6 5.4 09/02/2005 23:00:00 15.2 1.2 17.6 11.8 14.9 1.3 17.6 10.3 32 5 35 305 5.5 0 5.6 5.4 09/02/2005 23:10:00 15.4 1.1 17.6 11.8 15.1 1.2 17.6 10.7 31 5 33 305 5.5 0 5.6 5.4 09/02/2005 23:20:00 14.9 1.5 17.9 10.3 14.7 1.5 17.6 10.3 33 4 27 305 5.5 0 5.6 5.4 09/02/2005 23:30:00 15.2 1 17.6 11.5 15 1.1 17.2 11.5 31 4 33 305 5.4 0 5.6 5.4 09/02/2005 23:40:00 14.6 0.9 16.4 11.8 14.3 1.1 16.8 10.7 30 4 32 305 5.5 0 5.6 5.4 09/02/2005 23:50:00 14.6 1 16.8 11.1 14.4 1.2 16.8 10.7 30 5 35 305 5.4 0 5.6 5.2 09/03/2005 00:00:00 15 0.9 17.2 12.6 15 1 17.2 12.6 35 3 37 305 5.4 0 5.6 5.4 09/03/2005 00:10:00 13.7 0.9 15.6 10.7 13.6 1 15.3 10.7 34 4 32 305 5.5 0 5.6 5.4 09/03/2005 00:20:00 13.6 1 15.6 11.1 13.5 1.1 15.3 9.9 35 4 36 305 5.5 0 5.9 5.4 09/03/2005 00:30:00 13.3 0.9 15.3 10.3 13.3 0.9 15.3 10.3 31 4 35 305 5.6 0 5.6 5.4 09/03/2005 00:40:00 13 1 15.3 10.3 12.8 1 15.3 10.7 28 4 26 305 5.5 0 5.6 5.4 09/03/2005 00:50:00 13.3 0.9 15.3 10.7 13.4 1 15.6 10.3 28 3 25 305 5.5 0 5.6 5.4 09/03/2005 01:00:00 13.3 0.6 14.9 11.1 13.2 0.8 15.3 10.3 29 3 32 305 5.3 0 5.4 5.2 09/03/2005 01:10:00 12.9 0.6 14.1 10.7 12.9 0.8 14.5 9.9 25 5 28 305 5.2 0 5.4 5.2 09/03/2005 01:20:00 12.2 0.8 14.1 9.9 12.2 0.9 14.5 9.1 26 4 24 305 5.2 0 5.4 4.9 09/03/2005 01:30:00 11.9 0.7 13.3 9.9 12 0.9 14.1 9.1 22 4 20 305 5.1 0 5.4 4.9 09/03/2005 01:40:00 11.4 0.7 12.6 9.5 11.5 0.8 13.3 8.4 22 5 14 305 5 0 5.2 4.9 09/03/2005 01:50:00 11.4 0.7 13 9.1 11.5 0.8 13 8.8 22 4 27 305 4.9 0 5.2 4.9 09/03/2005 02:00:00 11 0.7 12.2 8.8 11.1 0.8 12.6 8.8 21 4 29 305 4.9 0 5.2 4.9 09/03/2005 02:10:00 11.3 0.7 12.6 8.8 11.5 0.8 13 8.8 21 5 18 305 4.8 0 4.9 4.9 09/03/2005 02:20:00 10.9 0.7 12.6 9.1 11.1 0.7 12.6 9.1 19 4 25 305 4.8 0 4.9 4.7 09/03/2005 02:30:00 11.2 0.5 12.2 9.5 11.3 0.6 13 8.8 19 4 19 305 4.8 0 4.9 4.7 09/03/2005 02:40:00 11.3 0.6 12.6 9.1 11.5 0.7 12.6 9.5 15 3 15 305 4.7 0 4.9 4.4 09/03/2005 02:50:00 10.9 0.6 12.2 8.8 11 0.7 12.6 8.4 15 5 24 305 4.6 0 4.7 4.4 09/03/2005 03:00:00 11 0.8 12.6 9.1 11.2 1 13.3 9.1 15 5 14 305 4.5 0 4.7 4.4 09/03/2005 03:10:00 11.5 0.7 13 8.8 11.6 0.8 13.3 8.8 14 4 12 305 4.4 0 4.7 4.4 09/03/2005 03:20:00 11.4 0.7 12.6 9.1 11.5 0.8 13 8.4 13 5 8 305 4.4 0 4.4 4.4 09/03/2005 03:30:00 11.7 0.8 13 9.1 11.9 0.8 13.3 9.5 16 5 14 305 4.4 0 4.7 4.2 09/03/2005 03:40:00 11.5 0.7 13 9.9 11.7 0.8 13.3 9.1 20 4 24 305 4.4 0 4.4 4.2 09/03/2005 03:50:00 11.3 0.7 13 9.1 11.5 0.8 13 9.1 21 5 17 305 4.3 0 4.7 4.2 09/03/2005 04:00:00 11.5 0.7 13 9.5 11.6 0.8 13 9.1 25 4 23 305 4.2 0 4.4 4.2 09/03/2005 04:10:00 11.7 0.7 13.3 9.1 11.8 0.8 13.3 8.8 24 5 28 305 4.2 0 4.4 4.2 09/03/2005 04:20:00 12 0.9 14.1 9.1 12.1 1 14.5 9.5 26 5 30 305 4.2 0 4.4 4.2 09/03/2005 04:30:00 12.3 0.8 14.1 9.9 12.4 0.8 14.5 9.9 26 5 25 305 4.1 0 4.4 3.9 09/03/2005 04:40:00 12.4 0.8 14.1 9.9 12.5 0.9 15.3 9.9 25 7 18 305 4 0 4.2 3.9 09/03/2005 04:50:00 11.8 0.8 13.3 9.5 12 0.9 14.1 9.1 19 4 16 305 4.1 0 4.4 3.9 09/03/2005 05:00:00 11.5 1 14.1 9.1 11.7 1 14.5 9.5 22 6 25 305 4 0 4.2 3.7 09/03/2005 05:10:00 11.5 0.9 13.7 9.5 11.5 1 13.7 9.5 29 5 20 305 4 0 4.2 3.7 09/03/2005 05:20:00 11.6 0.9 13.7 9.1 11.8 1 14.1 8.8 20 5 15 305 4 0 4.4 3.9 09/03/2005 05:30:00 11.5 1.2 14.5 8.8 11.5 1.1 14.5 9.1 21 6 22 305 4.1 0 4.4 3.9 09/03/2005 05:40:00 11.4 1 14.1 8.8 11.6 1 14.5 8.4 24 6 25 305 4.1 0 4.4 3.9 09/03/2005 05:50:00 12 1 14.5 8.8 11.9 1 14.5 9.1 29 6 25 305 4.2 0 4.4 4.2 09/03/2005 06:00:00 12.2 1 14.9 9.5 12.3 1.1 15.3 9.1 24 9 33 305 4.2 0 4.4 4.2 09/03/2005 06:10:00 11.9 0.9 13.7 8.8 11.9 1 13.7 9.1 24 6 33 305 4.3 0 4.4 4.2 09/03/2005 06:20:00 11.8 1 14.1 9.1 11.9 1 14.5 9.1 26 6 22 305 4.2 0 4.4 4.2 09/03/2005 06:30:00 11.7 0.9 14.1 9.5 11.9 1 14.1 9.5 28 9 14 305 4.3 0 4.4 4.2 09/03/2005 06:40:00 11.2 0.9 13.7 9.1 11.4 1 14.1 8.8 32 6 37 305 4.3 0 4.4 4.2 09/03/2005 06:50:00 10.4 0.8 12.6 8.4 10.5 1 13 8 25 8 25 305 4.5 0.1 4.7 4.2 09/03/2005 07:00:00 11.2 1 13.7 9.1 11.2 1 13.7 9.1 28 6 24 305 4.4 0 4.7 4.4 09/03/2005 07:10:00 10.5 0.8 12.6 8.8 10.6 0.8 13 8.8 23 7 12 305 4.6 0 4.9 4.4 09/03/2005 07:20:00 10.7 0.8 13 8 10.8 0.8 13 8.4 21 8 13 305 4.7 0 4.9 4.7 09/03/2005 07:30:00 11.1 0.8 13.3 9.1 11.2 0.8 13.7 9.1 29 7 29 305 4.6 0 4.7 4.4 09/03/2005 07:40:00 10.4 0.7 12.2 8.4 10.6 0.8 13 8 26 9 18 305 4.7 0 4.9 4.4 09/03/2005 07:50:00 9.9 0.9 12.2 7.6 9.9 0.9 12.2 7.6 26 6 19 305 4.8 0 4.9 4.7 09/03/2005 08:00:00 9.2 1 11.5 6.8 9.3 1 11.8 6.5 24 7 21 305 4.8 0 4.9 4.7 09/03/2005 08:10:00 9.5 1 11.8 7.2 9.7 1 12.6 7.6 16 6 12 305 4.8 0 4.9 4.7 09/03/2005 08:20:00 9 0.8 11.1 7.2 9.2 0.8 11.5 7.2 31 10 16 305 4.8 0 4.9 4.7 09/03/2005 08:30:00 9.3 1.1 11.8 6.5 9.5 1.1 12.2 6.8 22 7 23 305 4.8 0 5.2 4.7 09/03/2005 08:40:00 8.9 0.7 10.7 6.8 9 0.7 11.1 6.5 20 7 17 305 4.9 0 5.2 4.9 09/03/2005 08:50:00 9 1 11.5 6.1 9.1 1.1 11.8 6.5 22 6 32 305 4.9 0 5.2 4.9 09/03/2005 09:00:00 8.4 0.6 9.9 6.8 8.5 0.6 10.3 7.2 23 6 29 305 5 0 5.4 4.9 09/03/2005 09:10:00 8.8 0.9 11.1 6.5 8.9 0.9 11.5 6.8 16 5 13 305 5.1 0 5.4 4.9 09/03/2005 09:20:00 7.8 0.9 9.9 6.1 8 0.9 10.3 6.1 23 5 17 305 5 0 5.4 4.9 09/03/2005 09:30:00 8.7 0.6 10.3 7.2 8.9 0.6 10.3 6.8 19 5 17 305 5.2 0 5.4 4.9 09/03/2005 09:40:00 8 0.9 11.1 6.5 8.1 1 11.5 6.1 24 6 34 305 5.3 0 5.4 4.9 09/03/2005 09:50:00 8.3 0.9 10.7 5.7 8.4 0.9 10.7 6.1 23 7 16 305 5.3 0 5.4 5.2 09/03/2005 10:00:00 8.7 0.8 10.7 6.5 8.8 0.9 10.7 6.5 23 6 21 305 5.2 0 5.4 4.9 09/03/2005 10:10:00 8.1 0.6 9.5 6.5 8.2 0.6 9.5 6.8 26 6 30 305 5.2 0 5.4 5.2 09/03/2005 10:20:00 8.3 0.6 9.9 6.8 8.4 0.6 9.9 6.8 23 5 30 305 5.2 0 5.4 5.2 09/03/2005 10:30:00 7.4 0.8 9.5 6.1 7.6 0.8 9.1 6.1 17 5 13 305 5.2 0 5.4 4.9 09/03/2005 10:40:00 7.7 0.7 9.9 5.7 7.9 0.7 9.9 6.1 12 7 8 305 5.2 0 5.4 4.9 09/03/2005 10:50:00 7.1 0.5 8.8 6.1 7.3 0.6 9.1 5.3 6 4 6 305 5.2 0 5.4 4.9 09/03/2005 11:00:00 6.5 0.8 9.1 4.6 6.7 0.8 9.5 4.6 2 5 354 305 5.3 0 5.6 5.2 09/03/2005 11:10:00 6.9 0.6 8.8 5.7 7.2 0.7 9.1 5.7 1 5 12 305 5.3 0 5.6 5.2 09/03/2005 11:20:00 7.4 0.6 9.9 6.1 7.6 0.6 9.9 6.1 357 4 355 305 5.4 0 5.6 5.4 09/03/2005 11:30:00 7.5 0.6 9.1 6.1 7.8 0.7 9.1 5.7 357 4 350 305 5.4 0 5.6 5.4 09/03/2005 11:40:00 7.6 0.6 8.8 5.7 7.8 0.6 9.1 6.1 356 5 3 305 5.4 0 5.6 5.4 09/03/2005 11:50:00 7.4 0.5 8.4 6.1 7.7 0.5 9.1 6.5 352 3 351 305 5.4 0 5.6 5.4 09/03/2005 12:00:00 7.4 0.6 9.1 5.7 7.7 0.6 9.1 4.9 354 4 357 305 5.5 0 5.6 5.4 09/03/2005 12:10:00 7.8 0.5 9.1 6.5 8.1 0.5 9.5 6.8 354 4 357 305 5.5 0 5.6 5.4 09/03/2005 12:20:00 7.5 0.6 8.8 6.1 7.7 0.6 9.1 5.7 356 4 356 305 5.6 0 5.9 5.6 09/03/2005 12:30:00 7.1 0.5 8.4 5.3 7.4 0.6 8.8 5.7 356 5 0 305 5.7 0 5.9 5.4 09/03/2005 12:40:00 7.6 0.5 8.8 6.1 7.9 0.6 9.1 6.5 353 4 353 305 5.8 0 5.9 5.6 09/03/2005 12:50:00 7.6 0.5 8.8 6.5 8 0.6 9.1 6.1 353 3 354 305 5.6 0 5.9 5.6 09/03/2005 13:00:00 6.9 0.5 8 5.3 7.2 0.6 8.4 5.7 352 4 352 305 5.7 0 6.1 5.6 09/03/2005 13:10:00 6.7 0.6 8 4.9 7 0.7 8.4 4.9 356 5 358 305 5.9 0 6.4 5.6 09/03/2005 13:20:00 6.7 0.4 7.6 5.7 7 0.5 8 5.3 352 3 352 305 5.8 0 6.1 5.6 09/03/2005 13:30:00 6.3 0.5 7.2 4.9 6.5 0.5 7.6 4.9 352 4 350 305 5.9 0 6.4 5.6 09/03/2005 13:40:00 6.5 0.4 7.6 5.3 6.8 0.5 8 5.3 353 5 349 305 6 0 6.1 5.9 09/03/2005 13:50:00 5.8 0.5 6.8 4.6 6.1 0.6 7.2 4.6 354 5 1 305 5.8 0 6.1 5.6 09/03/2005 14:00:00 6.1 0.5 7.2 4.6 6.4 0.5 7.6 4.9 357 5 359 305 6 0 6.7 5.9 09/03/2005 14:10:00 6.3 0.5 7.6 4.9 6.6 0.5 8 5.3 0 5 7 305 6 0 6.4 5.9 09/03/2005 14:20:00 5.9 0.4 6.8 4.9 6.3 0.5 7.6 4.9 359 4 5 305 6 0 6.4 5.9 09/03/2005 14:30:00 5.8 0.5 7.2 4.2 6.1 0.5 7.6 4.9 357 4 359 305 6.1 0 6.4 5.9 09/03/2005 14:40:00 5.5 0.5 6.8 4.2 5.8 0.6 7.6 4.2 2 5 5 305 6.1 0.1 6.7 5.9 09/03/2005 14:50:00 5.6 0.7 7.6 3.8 5.8 0.7 7.6 3.8 6 8 354 305 6.1 0 6.4 5.9 09/03/2005 15:00:00 5.3 0.6 6.8 4.2 5.6 0.6 7.2 4.2 9 7 12 305 6.3 0 6.9 5.9 09/03/2005 15:10:00 4.6 0.6 6.1 3.4 4.9 0.6 6.5 3.4 15 10 22 305 6.3 0 6.7 6.1 09/03/2005 15:20:00 5 0.6 6.8 3.8 5.2 0.6 7.2 3.4 15 7 10 305 6.3 0 6.7 6.1 09/03/2005 15:30:00 5.1 0.8 6.8 3 5.4 0.9 7.6 3.4 9 5 4 305 6.2 0.1 6.4 5.9 09/03/2005 15:40:00 4.4 0.7 6.8 3 4.7 0.7 6.8 3.4 10 10 16 305 6.4 0 6.7 6.1 09/03/2005 15:50:00 3.8 0.4 4.9 3 4.2 0.4 5.3 3 357 7 7 305 6.5 0 7.2 6.1 09/03/2005 16:00:00 3.7 0.5 4.9 1.9 4.2 0.5 5.7 3 346 6 346 305 6.8 0 7.4 6.4 09/03/2005 16:10:00 3.6 0.5 4.9 2.6 4 0.5 5.3 3 348 7 343 305 6.9 0 7.2 6.7 09/03/2005 16:20:00 3.3 0.5 4.9 2.3 3.7 0.5 5.7 2.6 352 7 354 305 6.8 0 6.9 6.7 09/03/2005 16:30:00 3.2 0.4 4.2 1.9 3.5 0.4 4.6 2.3 345 8 343 305 6.8 0 7.2 6.9 09/03/2005 16:40:00 3.1 0.5 4.2 1.9 3.6 0.4 4.9 2.3 342 9 333 305 7 0 7.2 6.9 09/03/2005 16:50:00 2.8 0.5 4.2 1.5 3.2 0.5 4.6 2.3 349 8 332 305 7 0 7.2 6.9 09/03/2005 17:00:00 2.7 0.4 4.2 1.5 3.1 0.4 4.2 1.9 339 9 334 305 7 0 7.4 6.9 09/03/2005 17:10:00 2.5 0.6 3.8 0.7 2.9 0.5 4.2 1.5 321 8 334 305 7.2 0 7.4 7.2 09/03/2005 17:20:00 2.5 0.5 3.8 1.1 2.8 0.5 3.8 1.5 315 9 313 305 7.3 0 7.7 7.2 09/03/2005 17:30:00 3.2 0.5 4.6 2.3 3.4 0.5 4.9 2.3 319 9 313 305 7.2 0 7.4 7.2 09/03/2005 17:40:00 3.1 0.4 4.2 1.9 3.3 0.4 4.6 2.3 323 7 334 305 7.2 0 7.4 7.2 09/03/2005 17:50:00 3 0.4 4.2 1.9 3.2 0.4 4.2 2.3 321 7 330 305 7.2 0 7.4 7.2 09/03/2005 18:00:00 3.2 0.4 4.2 1.9 3.4 0.4 4.6 2.3 317 6 313 305 7.2 0 7.4 7.2 09/03/2005 18:10:00 3.4 0.4 4.6 2.3 3.6 0.4 4.6 2.6 311 7 312 305 7.2 0 7.4 7.2 09/03/2005 18:20:00 3 0.4 4.2 1.9 3.2 0.4 4.9 2.3 314 8 321 305 7.2 0 7.4 7.2 09/03/2005 18:30:00 3.3 0.4 4.2 1.9 3.5 0.4 4.6 2.6 317 9 317 305 7.1 0 7.2 7.2 09/03/2005 18:40:00 3.3 0.4 4.2 1.9 3.5 0.4 4.6 2.3 318 8 303 305 7.2 0 7.4 7.2 09/03/2005 18:50:00 2.9 0.4 3.8 1.9 3.2 0.4 4.6 1.9 321 7 318 305 7.2 0 7.4 7.2 09/03/2005 19:00:00 3.1 0.4 4.2 2.3 3.3 0.4 4.2 2.3 323 7 321 305 7.2 0 7.4 7.2 09/03/2005 19:10:00 3.1 0.3 4.2 2.3 3.3 0.4 4.2 2.3 332 6 341 305 6.7 0.1 7.2 6.7 09/03/2005 19:20:00 2.8 0.4 3.8 1.5 3.1 0.4 4.2 2.3 330 7 340 305 6.7 0 6.9 6.7 09/03/2005 19:30:00 3.1 0.4 4.2 1.9 3.4 0.5 4.6 2.3 340 10 341 305 6.7 0 6.9 6.4 09/03/2005 19:40:00 2.9 0.6 3.8 1.5 3.2 0.6 4.2 1.9 349 8 339 305 6.5 0 6.7 6.4 09/03/2005 19:50:00 2.9 0.8 4.6 1.5 3.1 0.7 4.9 1.5 357 10 356 305 6.5 0.1 6.9 6.1 09/03/2005 20:00:00 1.8 0.6 3.4 0.4 2.2 0.5 3.8 1.1 11 7 15 305 6.3 0 6.7 6.1 09/03/2005 20:10:00 2.6 0.4 3.4 1.5 2.9 0.4 4.2 2.3 3 6 345 305 6.3 0 6.4 6.1 09/03/2005 20:20:00 2.4 0.5 3.8 1.1 2.7 0.5 4.2 1.5 3 9 353 305 6.3 0 6.4 6.1 09/03/2005 20:30:00 1.8 0.5 3 0.7 2.2 0.4 3.4 1.1 18 11 0 305 6.3 0 6.4 6.1 09/03/2005 20:40:00 1.9 0.5 3 0.7 2.4 0.4 3.4 1.5 350 6 351 305 6.3 0 6.4 6.1 09/03/2005 20:50:00 1.2 0.5 2.6 0.4 1.8 0.3 2.6 0.7 2 9 8 305 6.3 0 6.4 6.1 09/03/2005 21:00:00 1.3 0.8 2.6 0.4 1.9 0.8 3.4 0.4 4 9 3 305 6.2 0 6.4 6.1 09/03/2005 21:10:00 1 0.7 2.3 0.4 1.7 0.6 2.6 0.7 357 2 359 305 6.1 0 6.1 5.9 09/03/2005 21:20:00 1.9 0.4 2.6 1.1 2.4 0.3 3 1.9 0 4 357 305 6.1 0 6.1 5.9 09/03/2005 21:30:00 1.6 0.3 2.6 0.7 2.1 0.3 2.6 1.5 350 7 353 305 6 0 6.1 5.9 09/03/2005 21:40:00 1.6 0.3 2.3 0.7 2.1 0.3 2.6 1.5 341 12 339 305 6 0 6.1 5.9 09/03/2005 21:50:00 1.6 0.4 2.6 0.7 2.2 0.4 3 1.1 356 4 352 305 6 0 6.1 5.9 09/03/2005 22:00:00 1.4 0.2 1.9 0.7 1.9 0.2 2.3 1.5 354 8 2 305 5.9 0 5.9 5.6 09/03/2005 22:10:00 1 0.2 1.5 0.4 1.7 0.2 2.3 1.1 339 9 339 305 5.8 0 5.9 5.6 09/03/2005 22:20:00 1.3 0.2 1.5 0.7 1.9 0.2 2.3 1.5 348 1 347 305 5.7 0 5.9 5.6 09/03/2005 22:30:00 1.2 0.2 1.5 0.7 1.8 0.2 2.3 1.5 353 6 347 305 5.6 0 5.9 5.6 09/03/2005 22:40:00 1.1 0.2 1.5 0.7 1.7 0.2 1.9 1.5 7 3 5 305 5.5 0 5.6 5.6 09/03/2005 22:50:00 0.4 0.2 1.1 0.4 1.1 0.2 1.9 0.7 8 2 8 305 5.5 0 5.6 5.4 09/03/2005 23:00:00 0.8 0.4 1.9 0.4 1.5 0.3 2.3 0.7 8 1 9 305 5 0.2 5.4 4.7 09/03/2005 23:10:00 1.2 0.3 1.9 0.7 1.8 0.3 2.3 1.1 9 2 7 305 4.5 0.1 4.9 4.4 09/03/2005 23:20:00 1 0.2 1.5 0.7 1.6 0.2 1.9 1.1 12 0 12 305 4.5 0.1 4.9 4.4 09/03/2005 23:30:00 1 0.2 1.5 0.4 1.6 0.2 1.9 1.1 17 1 13 305 4 0.2 4.7 3.7 09/03/2005 23:40:00 1.1 0.2 1.9 0.4 1.6 0.2 1.9 0.7 17 1 17 305 3.9 0 4.4 3.7 09/03/2005 23:50:00 0.7 0.3 1.1 0.4 1.1 0.4 1.5 0.4 15 2 18 305 3.7 0 4.2 3.4 09/04/2005 00:00:00 0.4 0.2 1.1 0.4 0.6 0.2 1.5 0.4 12 3 9 305 3.6 0 4.2 3.4 09/04/2005 00:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 15 1 305 305 3.5 0 3.9 3.4 09/04/2005 00:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 16 1 305 305 3.5 0.1 4.2 3.4 09/04/2005 00:30:00 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 18 6 305 305 3.4 0.1 3.7 3.2 09/04/2005 00:40:00 0.7 0.4 1.5 0.4 1.2 0.2 1.5 0.7 36 4 39 305 3.3 0.1 3.7 3.2 09/04/2005 00:50:00 0.6 0.3 1.5 0.4 0.9 0.2 1.5 0.4 24 7 30 305 3.3 0 3.7 3.2 09/04/2005 01:00:00 0.6 0.2 1.1 0.4 1.2 0.2 1.9 0.7 36 8 37 305 3.4 0 3.9 3.2 09/04/2005 01:10:00 1.4 0.6 2.6 0.4 1.8 0.5 3 1.1 38 11 28 305 3.4 0.1 3.7 3.2 09/04/2005 01:20:00 1.9 0.3 2.6 1.1 2.4 0.3 3 1.5 29 4 33 305 4 0 4.4 3.7 09/04/2005 01:30:00 1.5 0.2 2.3 0.7 2 0.2 2.6 1.5 23 2 26 305 3.7 0 3.9 3.4 09/04/2005 01:40:00 1.9 0.3 2.6 1.1 2.3 0.3 2.6 1.5 20 7 13 305 3.7 0 3.7 3.4 09/04/2005 01:50:00 2.3 0.2 2.6 1.9 2.7 0.2 3 1.9 24 4 30 305 3.9 0 4.2 3.7 09/04/2005 02:00:00 2.2 0.3 3 1.5 2.7 0.3 3.4 2.3 22 6 18 305 4.2 0.4 4.9 3.7 09/04/2005 02:10:00 2.2 0.3 3 1.5 2.7 0.2 3.4 2.3 18 2 18 305 5.3 0.2 5.9 4.9 09/04/2005 02:20:00 2.3 0.2 2.6 1.9 2.8 0.2 3.4 2.3 19 5 14 305 5.6 0.1 6.1 5.4 09/04/2005 02:30:00 2.4 0.2 3 1.9 2.8 0.2 3.4 2.3 25 5 26 305 5.5 0 5.9 5.4 09/04/2005 02:40:00 2.8 0.4 3.4 1.9 3.2 0.4 3.8 2.3 26 4 28 305 5.4 0 5.6 5.4 09/04/2005 02:50:00 3.5 0.4 4.6 2.6 3.9 0.4 4.6 3 29 4 31 305 5.4 0 5.9 5.4 09/04/2005 03:00:00 3.7 0.4 4.6 2.6 4 0.4 4.9 3 32 5 37 305 5.4 0 5.9 5.2 09/04/2005 03:10:00 3.8 0.4 4.9 2.6 4.1 0.4 4.9 3 34 4 29 305 5.5 0 5.6 5.4 09/04/2005 03:20:00 3.8 0.3 4.6 3 4.1 0.3 4.9 3.4 33 5 41 305 5.6 0 6.1 5.6 09/04/2005 03:30:00 2.9 0.5 3.8 1.9 3.2 0.5 4.2 2.3 26 2 29 305 5.7 0 6.1 5.6 09/04/2005 03:40:00 2.2 0.5 3.4 1.1 2.6 0.4 3.8 1.9 28 4 35 305 5.7 0.1 6.4 5.6 09/04/2005 03:50:00 3.4 0.4 4.6 2.6 3.8 0.4 4.6 3 30 4 23 305 5.7 0.1 6.1 5.6 09/04/2005 04:00:00 4.4 0.5 4.9 3 4.6 0.5 5.3 3.4 34 4 33 305 5.6 0.1 6.1 5.6 09/04/2005 04:10:00 4.5 0.2 4.9 3.8 4.8 0.3 5.7 4.2 29 5 38 305 5.7 0.1 6.1 5.6 09/04/2005 04:20:00 4.1 0.3 4.9 3.4 4.4 0.3 5.3 3.8 25 3 26 305 5.6 0 6.1 5.6 09/04/2005 04:30:00 4.7 0.3 5.7 3.8 5 0.3 5.7 4.2 29 4 42 305 5.8 0 6.4 5.6 09/04/2005 04:40:00 5.1 0.3 6.1 4.2 5.4 0.3 6.1 4.6 34 3 38 305 5.9 0 5.9 5.9 09/04/2005 04:50:00 5.9 0.5 6.8 4.6 6.1 0.5 7.2 4.6 36 5 33 305 6 0 5.9 5.9 09/04/2005 05:00:00 6.3 0.3 6.8 5.7 6.4 0.3 7.2 5.3 37 3 32 305 6 0 6.1 5.9 09/04/2005 05:10:00 6.1 0.4 6.8 4.9 6.3 0.5 7.2 4.6 38 3 40 305 6 0 6.1 5.9 09/04/2005 05:20:00 6 0.4 6.8 4.9 6.2 0.4 7.2 4.6 38 3 40 305 6 0 6.1 5.9 09/04/2005 05:30:00 5.7 0.5 6.8 4.6 6 0.5 6.8 4.9 38 3 44 305 6.1 0 6.1 5.9 09/04/2005 05:40:00 5.9 0.4 6.8 4.6 6 0.5 6.8 4.9 38 3 39 305 6.2 0 6.4 6.1 09/04/2005 05:50:00 6.2 0.5 7.2 4.9 6.3 0.6 7.6 4.9 40 4 41 305 6.2 0 6.4 6.1 09/04/2005 06:00:00 7 0.6 8.4 5.3 7.1 0.6 8.8 5.7 43 4 44 305 6.3 0 6.4 6.1 09/04/2005 06:10:00 8.4 0.4 9.1 7.2 8.5 0.4 9.5 7.2 48 3 48 305 6.3 0 6.4 6.1 09/04/2005 06:20:00 8.3 0.4 9.5 7.2 8.3 0.5 9.5 6.8 48 4 50 305 6 0 6.1 5.9 09/04/2005 06:30:00 8.3 0.5 9.5 6.8 8.4 0.6 9.5 6.8 53 4 52 305 6 0 5.9 5.9 09/04/2005 06:40:00 8.7 0.5 9.5 6.8 8.8 0.6 9.9 6.5 49 3 48 305 5.9 0 5.9 5.9 09/04/2005 06:50:00 8.7 0.6 9.9 7.2 8.7 0.7 9.9 7.2 52 3 55 305 5.8 0 5.9 5.6 09/04/2005 07:00:00 8.4 0.5 9.5 6.8 8.5 0.5 9.5 6.8 54 4 58 305 5.9 0 5.9 5.9 09/04/2005 07:10:00 8.1 0.5 9.1 6.8 8.2 0.6 9.5 6.5 53 3 51 305 6 0 6.1 5.9 09/04/2005 07:20:00 8.5 0.5 9.9 6.8 8.6 0.6 9.9 7.2 49 3 47 305 6.1 0 6.1 5.9 09/04/2005 07:30:00 9 0.5 10.3 7.2 9 0.6 10.3 7.2 51 4 48 305 6.1 0 6.1 5.9 09/04/2005 07:40:00 8.8 0.5 10.3 7.2 8.8 0.6 9.9 6.5 58 4 59 305 6 0 6.1 5.9 09/04/2005 07:50:00 8.8 0.6 9.9 7.2 8.9 0.6 10.3 6.8 55 4 55 305 5.9 0 5.9 5.9 09/04/2005 08:00:00 8.8 0.5 9.9 6.8 8.8 0.5 9.9 7.2 56 4 61 305 5.8 0 6.1 5.6 09/04/2005 08:10:00 8.8 0.7 10.3 6.5 8.8 0.7 10.3 6.5 58 4 54 305 5.8 0 5.9 5.6 09/04/2005 08:20:00 9.4 0.6 10.7 7.2 9.4 0.7 10.7 7.2 57 3 61 305 5.9 0 6.1 5.9 09/04/2005 08:30:00 9.9 0.5 11.1 8.4 9.8 0.7 11.5 8 59 2 62 305 5.8 0 5.9 5.9 09/04/2005 08:40:00 9.7 0.7 11.1 7.6 9.6 0.8 11.1 7.2 62 5 63 305 6 0 6.1 5.9 09/04/2005 08:50:00 9.8 0.6 11.1 7.6 9.8 0.8 11.1 7.2 60 3 57 305 6 0 6.4 5.9 09/04/2005 09:00:00 10.3 0.8 11.8 7.6 10.3 0.9 11.8 7.2 62 4 62 305 6 0 6.4 5.9 09/04/2005 09:10:00 10.2 0.6 11.5 8.4 10 0.8 11.5 7.6 63 5 60 305 6 0 6.4 5.9 09/04/2005 09:20:00 10.2 0.9 11.8 7.6 10.2 1 11.8 7.6 64 6 68 305 6 0 6.4 5.9 09/04/2005 09:30:00 10.6 0.7 12.2 8 10.5 0.8 12.2 8.4 60 4 55 305 6 0 6.4 5.9 09/04/2005 09:40:00 10.9 0.6 12.2 9.1 10.8 0.7 12.6 8.8 60 3 58 305 5.8 0 6.1 5.6 09/04/2005 09:50:00 10.8 0.6 12.2 8.4 10.7 0.7 12.2 7.6 64 4 64 305 5.8 0 6.1 5.6 09/04/2005 10:00:00 11 0.8 12.2 8.4 10.9 1 12.2 8 61 4 62 305 5.6 0.1 5.9 5.4 09/04/2005 10:10:00 11.5 0.7 13 9.5 11.4 0.8 13.3 8.8 61 4 57 305 5.4 0 5.6 5.4 09/04/2005 10:20:00 11.5 0.8 13 9.5 11.3 1 13.3 8 61 4 64 305 5.3 0 5.6 5.2 09/04/2005 10:30:00 11.7 0.9 13.7 9.5 11.5 1 13.3 8.4 60 4 55 305 5.2 0 5.4 4.9 09/04/2005 10:40:00 11.8 0.8 13.7 9.5 11.6 1 13.7 8.8 60 4 59 305 5.2 0 5.4 5.2 09/04/2005 10:50:00 12.2 0.7 13.7 10.3 12.1 0.9 14.1 9.5 63 4 59 305 5.1 0 5.4 4.9 09/04/2005 11:00:00 12.8 0.8 14.5 10.3 12.7 1 14.5 9.1 60 5 62 305 5.1 0 5.4 4.9 09/04/2005 11:10:00 12 1 14.1 9.1 11.9 1.2 14.1 8.4 60 6 62 305 5.2 0 5.4 4.9 09/04/2005 11:20:00 11.7 0.9 13.7 9.5 11.4 1.2 13.7 8.4 58 6 56 305 5.3 0.1 5.6 4.9 09/04/2005 11:30:00 11.8 1 14.1 9.1 11.8 1 14.1 8.4 54 5 51 305 5.3 0 5.6 5.2 09/04/2005 11:40:00 11.5 1 14.1 8.4 11.3 1 13.3 8.4 55 6 52 305 5.4 0 5.6 5.2 09/04/2005 11:50:00 11.2 1 14.5 8.8 11 1.1 14.5 8.4 58 6 58 305 5.5 0.1 5.9 5.4 09/04/2005 12:00:00 11.3 1 13.7 8.8 11.2 1 13.3 8.4 61 5 57 305 5.6 0 5.9 5.4 09/04/2005 12:10:00 11.5 1 14.1 8.4 11.4 1.1 14.1 8.4 56 6 60 305 5.7 0 5.9 5.6 09/04/2005 12:20:00 11.5 1.1 13.7 8.8 11.3 1.2 14.1 8.4 55 6 52 305 5.8 0 6.4 5.6 09/04/2005 12:30:00 11.7 0.9 14.1 9.1 11.6 1 13.7 8.8 54 5 48 305 5.8 0 6.4 5.6 09/04/2005 12:40:00 12.3 0.8 14.1 10.3 12.2 0.8 14.1 9.5 54 3 57 305 5.9 0.1 6.4 5.6 09/04/2005 12:50:00 11.9 1 13.7 9.1 11.8 1.1 13.7 8 59 6 54 305 6.1 0.1 6.7 5.9 09/04/2005 13:00:00 11.9 0.7 13.7 9.9 11.7 0.8 13.7 9.1 50 4 48 305 6.1 0.1 6.9 5.9 09/04/2005 13:10:00 12.2 0.8 14.5 10.3 12 0.9 14.1 9.9 51 4 61 305 6 0 6.4 5.9 09/04/2005 13:20:00 12.3 0.9 14.1 9.9 12.3 0.9 14.1 9.1 52 5 45 305 6 0.1 6.4 5.9 09/04/2005 13:30:00 12.1 0.8 14.1 9.5 12 1 14.1 9.1 53 4 49 305 6 0 6.4 5.9 09/04/2005 13:40:00 11.9 0.9 14.1 9.1 11.8 1 14.1 9.5 53 4 52 305 6 0.1 6.4 5.9 09/04/2005 13:50:00 11.7 0.8 13.7 8.4 11.5 0.9 13.3 8 53 5 49 305 6.1 0.1 6.7 5.9 09/04/2005 14:00:00 11.7 1 13.7 8 11.5 1.1 13.3 7.6 53 5 46 305 6 0.1 6.4 5.9 09/04/2005 14:10:00 12 0.7 13.7 9.5 11.8 1 13.7 8.8 51 4 49 305 6 0 6.4 5.9 09/04/2005 14:20:00 12.5 0.8 14.1 10.3 12.4 0.8 14.5 10.3 48 3 45 305 6 0 6.4 5.9 09/04/2005 14:30:00 12.7 0.8 14.5 10.3 12.7 1 14.5 9.5 47 4 48 305 5.9 0 6.4 5.6 09/04/2005 14:40:00 12.4 0.7 14.1 10.3 12.3 0.9 14.1 9.1 46 4 46 305 5.8 0 5.9 5.6 09/04/2005 14:50:00 12.3 0.8 14.5 9.9 12.2 0.9 14.5 9.5 46 4 43 305 5.8 0 5.9 5.6 09/04/2005 15:00:00 12.3 0.8 13.7 9.5 12.2 0.9 14.1 9.1 47 5 57 305 5.8 0 5.9 5.6 09/04/2005 15:10:00 12.4 0.7 14.1 10.3 12.3 0.7 14.1 10.3 49 4 52 305 5.8 0 5.9 5.6 09/04/2005 15:20:00 13 0.7 14.5 11.1 13.1 0.8 14.9 9.9 47 4 44 305 5.8 0 5.9 5.6 09/04/2005 15:30:00 13.2 0.9 14.9 10.7 13.2 0.9 14.9 11.1 44 4 41 305 5.8 0 6.1 5.6 09/04/2005 15:40:00 13.5 0.9 15.3 10.7 13.3 1.1 15.3 10.3 44 5 41 305 5.8 0 5.9 5.6 09/04/2005 15:50:00 13.1 1 15.3 9.5 13 1.1 14.9 9.1 46 4 43 305 5.9 0 5.9 5.9 09/04/2005 16:00:00 13.5 0.8 15.3 11.1 13.5 1 15.3 9.9 44 3 42 305 5.8 0 5.9 5.6 09/04/2005 16:10:00 13.1 0.8 14.9 10.7 13 1 15.3 10.3 44 4 41 305 5.8 0 5.9 5.6 09/04/2005 16:20:00 13.5 0.6 14.9 11.8 13.4 0.7 14.9 11.1 46 4 41 305 5.7 0 5.9 5.6 09/04/2005 16:30:00 13 0.8 14.9 10.3 12.8 1 14.9 10.3 48 4 49 305 5.8 0 5.9 5.6 09/04/2005 16:40:00 13.3 0.7 14.9 10.7 13.2 0.8 15.3 10.7 45 4 48 305 5.6 0 6.1 5.6 09/04/2005 16:50:00 13.3 0.8 14.9 10.7 13.3 0.9 15.3 10.3 45 4 40 305 5.6 0.1 5.9 5.4 09/04/2005 17:00:00 13.2 0.8 14.9 11.1 13.1 0.9 15.3 10.3 45 5 37 305 5.6 0.1 6.1 5.4 09/04/2005 17:10:00 13.1 0.8 14.5 9.9 13 0.8 14.9 9.5 48 5 43 305 5.6 0.1 6.1 5.4 09/04/2005 17:20:00 12.8 1 14.5 9.9 12.7 1.1 15.3 9.1 50 5 53 305 5.7 0.2 6.1 5.4 09/04/2005 17:30:00 13.3 0.8 14.9 10.7 13.2 0.8 14.9 10.7 53 4 53 305 5.6 0.1 6.1 5.4 09/04/2005 17:40:00 12.9 0.6 14.1 10.7 12.9 0.7 14.5 10.3 50 4 57 305 5.7 0.1 6.1 5.6 09/04/2005 17:50:00 12.8 0.7 14.9 10.3 12.8 0.8 14.5 10.3 50 4 45 305 5.8 0.1 6.1 5.6 09/04/2005 18:00:00 12.7 0.9 14.9 10.3 12.5 1 14.9 9.5 47 5 41 305 6 0.1 6.4 5.9 09/04/2005 18:10:00 13.3 0.7 14.9 11.5 13.2 0.8 14.9 10.3 47 5 43 305 6 0 6.4 5.9 09/04/2005 18:20:00 13.2 0.8 15.3 10.7 13.1 1 15.6 9.9 47 5 50 305 6 0 6.4 5.9 09/04/2005 18:30:00 13.7 0.8 16.1 11.1 13.6 1 15.6 10.3 45 4 44 305 6 0.1 6.4 5.9 09/04/2005 18:40:00 13.2 0.9 14.9 10.7 13.1 1 14.9 10.3 47 4 54 305 6 0.1 6.7 5.9 09/04/2005 18:50:00 12.9 0.8 14.9 10.7 12.8 0.9 14.5 10.3 47 4 43 305 6 0.1 6.7 5.9 09/04/2005 19:00:00 13.5 0.7 15.3 11.5 13.4 0.8 15.3 10.3 44 3 44 305 5.8 0 6.4 5.6 09/04/2005 19:10:00 13 1.1 15.6 9.9 12.9 1.2 16.1 9.9 46 5 40 305 5.9 0 6.1 5.9 09/04/2005 19:20:00 13.4 1 16.1 10.7 13.1 1.2 15.6 9.9 47 5 38 305 6 0.1 6.4 5.9 09/04/2005 19:30:00 13.3 1 15.6 10.3 13.1 1.1 15.6 10.3 49 5 48 305 6 0 6.4 5.9 09/04/2005 19:40:00 13.6 1 15.6 9.5 13.5 1 15.3 10.3 47 5 47 305 6 0 6.4 5.9 09/04/2005 19:50:00 13.2 1 15.3 10.3 13.1 1.1 15.3 10.3 45 5 38 305 6 0.1 6.4 5.9 09/04/2005 20:00:00 13.9 1 16.1 11.1 13.8 1.1 16.1 10.3 42 4 44 305 5.9 0 6.1 5.9 09/04/2005 20:10:00 13.7 0.8 15.3 11.5 13.6 0.9 15.6 11.1 44 4 45 305 6 0 5.9 5.9 09/04/2005 20:20:00 13.4 1 15.3 11.1 13.3 1 15.6 11.1 43 5 36 305 6 0 6.1 5.9 09/04/2005 20:30:00 13.6 1 16.1 11.5 13.4 1 16.1 10.7 42 5 40 305 6 0 6.1 5.9 09/04/2005 20:40:00 13.5 1 16.4 10.3 13.4 1.2 16.4 10.3 46 4 50 305 6 0 6.1 5.9 09/04/2005 20:50:00 13.9 1 16.1 10.3 13.9 1.2 16.1 9.9 46 4 46 305 5.9 0 6.1 5.9 09/04/2005 21:00:00 14 1 16.4 11.1 14 1.1 16.4 10.7 47 4 45 305 6 0 6.1 5.9 09/04/2005 21:10:00 14.5 1.1 16.4 11.1 14.4 1.2 17.2 11.5 48 4 51 305 5.9 0 6.4 5.9 09/04/2005 21:20:00 13.5 1.2 16.1 10.3 13.2 1.3 16.1 9.9 50 5 52 305 6 0.1 6.4 5.9 09/04/2005 21:30:00 14.1 1.1 16.8 10.7 14 1.1 16.4 10.3 49 4 46 305 6 0 6.4 5.9 09/04/2005 21:40:00 13.8 0.9 15.3 11.1 13.6 1 15.3 10.7 47 5 47 305 5.9 0 6.4 5.9 09/04/2005 21:50:00 14.1 1 16.8 11.5 14 1 16.4 11.5 47 4 47 305 5.8 0 6.1 5.6 09/04/2005 22:00:00 13.6 1.2 16.8 11.1 13.5 1.3 16.8 10.3 47 4 45 305 5.9 0 6.1 5.9 09/04/2005 22:10:00 14.5 0.8 16.8 12.2 14.4 0.9 16.4 11.5 45 4 44 305 5.8 0 5.9 5.6 09/04/2005 22:20:00 14.2 1 16.1 11.5 14 1.1 16.4 11.5 46 5 46 305 5.9 0 6.4 5.9 09/04/2005 22:30:00 14.6 1 16.4 10.7 14.4 1 16.4 10.7 45 4 45 305 5.8 0 5.9 5.6 09/04/2005 22:40:00 13.9 1.2 16.8 11.5 13.7 1.3 16.8 10.3 47 5 48 305 5.8 0 5.9 5.6 09/04/2005 22:50:00 14.4 1.2 16.8 11.5 14.3 1.2 16.8 10.7 47 5 52 305 5.8 0 5.9 5.6 09/04/2005 23:00:00 14.8 0.9 16.8 11.5 14.6 1.1 16.8 10.7 48 5 46 305 5.8 0 5.9 5.6 09/04/2005 23:10:00 14.1 1.1 16.4 10.7 13.8 1.2 16.4 9.9 45 4 48 305 5.8 0 5.9 5.6 09/04/2005 23:20:00 14.7 1 16.4 11.1 14.6 1 16.4 11.5 44 4 48 305 5.8 0 5.9 5.6 09/04/2005 23:30:00 14.9 0.8 17.2 12.6 14.8 1 16.8 11.8 45 4 52 305 5.7 0 5.9 5.6 09/04/2005 23:40:00 14.5 1.2 16.8 11.1 14.3 1.2 16.8 10.7 44 5 44 305 5.6 0 5.9 5.6 09/04/2005 23:50:00 14.5 1 16.8 12.2 14.3 1.1 17.2 11.8 41 5 42 305 5.6 0 5.9 5.6 09/05/2005 00:00:00 14.6 1.1 17.2 11.5 14.4 1.2 16.8 11.5 42 4 45 305 5.6 0 5.9 5.4 09/05/2005 00:10:00 13.8 0.8 15.6 11.1 13.7 1 16.1 11.1 44 4 53 305 5.7 0 5.9 5.6 09/05/2005 00:20:00 14.7 0.8 16.8 12.2 14.6 0.9 17.2 11.8 46 4 46 305 5.8 0 5.9 5.6 09/05/2005 00:30:00 13.9 1.1 16.1 10.3 13.7 1.2 16.1 10.3 47 5 41 305 5.8 0 5.9 5.6 09/05/2005 00:40:00 13.4 1.1 16.1 10.3 13.2 1.1 15.3 9.9 48 5 46 305 5.8 0 5.9 5.6 09/05/2005 00:50:00 13.3 1.1 15.6 9.5 13.1 1.2 15.6 9.1 45 4 45 305 5.8 0 5.9 5.6 09/05/2005 01:00:00 13.5 1 15.3 10.3 13.2 1.1 15.3 10.7 45 4 48 305 5.7 0 5.9 5.6 09/05/2005 01:10:00 13.2 1.3 16.1 9.9 13 1.4 16.4 9.5 48 4 44 305 5.8 0 5.9 5.6 09/05/2005 01:20:00 13 1 15.6 9.5 12.8 1.1 15.3 9.5 50 5 58 305 5.9 0 5.9 5.6 09/05/2005 01:30:00 13.3 1 15.6 10.3 13 1.1 16.1 10.3 53 4 55 305 6 0 6.1 5.9 09/05/2005 01:40:00 13.6 1 16.1 11.1 13.4 1.1 16.1 10.3 52 4 53 305 6 0 6.1 5.9 09/05/2005 01:50:00 13.6 1.2 15.6 9.5 13.4 1.3 15.6 9.9 54 4 47 305 6.1 0 6.1 5.9 09/05/2005 02:00:00 13.9 1.1 15.6 10.7 13.7 1.2 15.6 10.3 55 4 52 305 6.1 0 6.1 5.9 09/05/2005 02:10:00 13.2 1 15.3 9.9 13 1 15.3 10.3 56 6 57 305 6.1 0 6.1 6.1 09/05/2005 02:20:00 13.5 1 16.1 11.1 13.3 1 16.1 11.1 56 5 47 305 6.1 0 6.1 5.9 09/05/2005 02:30:00 13.9 1 16.1 10.7 13.7 1.1 16.1 10.7 56 5 52 305 6.1 0 6.1 5.9 09/05/2005 02:40:00 13.9 0.9 15.6 11.8 13.6 1.1 16.1 10.3 51 4 57 305 6 0 6.1 5.9 09/05/2005 02:50:00 14.4 1 16.8 11.5 14.1 1.1 16.4 10.7 54 4 55 305 6 0 6.1 5.9 09/05/2005 03:00:00 14.1 1 16.4 11.8 13.9 1 16.4 11.1 56 5 55 305 6 0 6.1 5.9 09/05/2005 03:10:00 13.8 1.2 16.1 11.1 13.5 1.3 16.4 10.7 56 6 50 305 6 0 6.1 5.9 09/05/2005 03:20:00 14.1 1.5 16.8 10.7 13.9 1.6 17.2 9.5 57 6 52 305 6 0 6.1 5.9 09/05/2005 03:30:00 14.1 1.1 16.1 11.1 13.9 1.2 16.4 10.7 57 5 54 305 6 0 6.1 5.9 09/05/2005 03:40:00 15 0.9 16.4 12.2 14.9 1 17.2 11.5 52 4 48 305 6 0 6.1 5.9 09/05/2005 03:50:00 14.7 1 16.8 12.2 14.5 1.1 16.8 11.5 53 5 56 305 6 0 5.9 5.9 09/05/2005 04:00:00 14.5 1 17.2 11.8 14.3 1.2 17.2 11.1 53 5 56 305 6 0 6.1 5.9 09/05/2005 04:10:00 13.6 1 16.1 11.1 13.6 1 16.4 11.1 46 8 64 305 5.8 0 5.9 5.6 09/05/2005 04:20:00 13.9 0.9 16.1 11.8 14 0.9 15.6 11.8 43 4 44 305 5.6 0 5.9 5.6 09/05/2005 04:30:00 13.9 0.9 16.1 10.7 13.8 1 15.6 11.1 46 5 45 305 5.5 0.1 5.9 5.4 09/05/2005 04:40:00 14.6 1 16.8 12.2 14.4 1.1 16.8 11.1 44 5 48 305 5.5 0 5.6 5.4 09/05/2005 04:50:00 14.9 0.9 16.8 12.2 14.7 1 16.8 11.1 43 5 48 305 5.5 0 5.6 5.4 09/05/2005 05:00:00 14.5 1 16.8 11.8 14.3 1 16.8 11.5 43 5 46 305 5.4 0 5.6 5.4 09/05/2005 05:10:00 14.1 1 16.8 11.5 13.9 1.2 16.4 10.7 45 5 49 305 5.4 0 5.6 5.4 09/05/2005 05:20:00 14.6 0.9 16.8 11.8 14.5 1 16.8 11.5 46 4 39 305 5.4 0 5.6 5.4 09/05/2005 05:30:00 14.3 0.9 16.8 11.8 14.2 1 16.4 11.1 43 4 42 305 5.5 0 5.6 5.4 09/05/2005 05:40:00 13.9 1 15.6 10.7 13.7 1.2 15.6 10.3 41 5 44 305 5.5 0 5.6 5.4 09/05/2005 05:50:00 14.2 1 16.4 11.5 14.1 1.1 16.8 9.9 41 5 38 305 5.6 0 5.9 5.4 09/05/2005 06:00:00 14.1 1 16.4 9.9 14 1 16.4 10.7 39 5 37 305 5.5 0 5.9 5.4 09/05/2005 06:10:00 13.7 1 15.6 10.7 13.6 1.1 15.6 10.7 38 5 38 305 5.5 0 5.6 5.4 09/05/2005 06:20:00 14.9 1 16.8 12.2 14.8 1 16.8 11.8 39 4 39 305 5.5 0 5.6 5.4 09/05/2005 06:30:00 14.3 1.1 16.4 11.1 14 1.2 16.8 10.7 37 4 37 305 5.5 0 5.6 5.4 09/05/2005 06:40:00 14.5 1 16.8 12.2 14.5 1.1 16.8 11.5 37 4 33 305 5.5 0 5.6 5.4 09/05/2005 06:50:00 14.8 1 16.8 12.2 14.7 1.1 16.8 10.7 40 4 41 305 5.5 0 5.6 5.4 09/05/2005 07:00:00 14 1.1 16.8 11.1 13.9 1.2 17.2 10.7 40 5 36 305 5.7 0 5.9 5.6 09/05/2005 07:10:00 14.7 1.1 16.4 10.7 14.5 1.3 16.4 10.3 38 4 39 305 5.6 0.1 5.9 5.4 09/05/2005 07:20:00 14.7 1 16.8 11.5 14.5 1.1 17.2 11.5 39 5 38 305 5.6 0 5.9 5.4 09/05/2005 07:30:00 14.3 0.9 16.4 12.2 14.2 1 16.4 11.5 38 5 38 305 5.6 0 5.9 5.4 09/05/2005 07:40:00 14.2 1.2 16.8 11.1 14.1 1.3 17.2 10.3 38 5 32 305 5.6 0 5.9 5.4 09/05/2005 07:50:00 14.2 1.2 16.8 11.1 14.1 1.3 17.2 10.3 39 5 37 305 5.6 0 5.9 5.4 09/05/2005 08:00:00 14.1 1.2 16.4 11.1 14 1.3 16.8 10.7 38 5 33 305 5.8 0 5.9 5.6 09/05/2005 08:10:00 14.6 1 16.8 11.1 14.5 1.1 17.6 11.8 38 4 33 305 5.8 0 5.9 5.6 09/05/2005 08:20:00 14.6 1 16.8 11.8 14.5 1.1 16.8 11.5 37 4 36 305 5.8 0 5.9 5.6 09/05/2005 08:30:00 14.6 1 16.4 11.8 14.6 1 16.8 11.5 38 4 38 305 5.8 0 5.9 5.6 09/05/2005 08:40:00 14.4 1.2 17.2 11.1 14.3 1.2 17.6 10.3 39 5 40 305 5.9 0 5.9 5.6 09/05/2005 08:50:00 14.7 0.9 17.2 12.2 14.6 1 17.6 11.8 39 5 37 305 6 0 6.1 5.9 09/05/2005 09:00:00 14.3 1.2 16.4 11.1 14.3 1.3 16.4 10.7 39 5 38 305 6 0 6.1 5.9 09/05/2005 09:10:00 14.3 1.1 16.4 11.1 14.2 1.1 16.4 11.1 39 4 41 305 6 0 6.1 5.9 09/05/2005 09:20:00 14.6 1 16.8 11.1 14.6 1.1 16.8 11.1 37 4 39 305 6 0 6.1 5.9 09/05/2005 09:30:00 14.3 1 16.8 11.5 14.2 1.1 16.4 11.5 37 4 34 305 6 0 6.1 5.9 09/05/2005 09:40:00 14.3 0.8 16.1 12.2 14.3 0.9 16.1 11.5 38 4 36 305 6 0 6.1 5.9 09/05/2005 09:50:00 14.3 0.8 16.4 11.1 14.3 1 16.1 11.1 39 4 40 305 6.1 0 6.4 5.9 09/05/2005 10:00:00 14.1 1.1 17.2 11.1 14 1.2 16.8 11.1 41 5 39 305 6.3 0 6.4 6.1 09/05/2005 10:10:00 14.5 1 16.8 11.5 14.4 1 17.2 11.1 45 5 37 305 6.5 0 6.7 6.1 09/05/2005 10:20:00 15 0.9 17.2 12.2 14.8 1.1 17.2 11.5 44 5 43 305 6.5 0 6.7 6.4 09/05/2005 10:30:00 14.8 1.4 17.2 10.3 14.5 1.5 17.2 9.5 43 6 46 305 6.6 0 6.9 6.4 09/05/2005 10:40:00 14.7 1.3 17.2 11.1 14.5 1.4 17.2 11.1 47 4 52 305 6.7 0 6.9 6.4 09/05/2005 10:50:00 14.9 1.1 17.2 11.5 14.7 1.1 17.2 11.1 44 5 38 305 6.6 0 6.9 6.4 09/05/2005 11:00:00 15.2 1.1 17.6 11.8 15 1.2 17.9 11.8 43 5 41 305 6.6 0.1 7.2 6.4 09/05/2005 11:10:00 15.5 1.1 17.6 11.8 15.3 1.2 17.6 11.8 45 5 51 305 6.7 0.1 7.2 6.4 09/05/2005 11:20:00 15.3 1.1 17.6 11.8 15.2 1.1 17.9 12.2 46 5 44 305 6.7 0.1 7.2 6.4 09/05/2005 11:30:00 15.5 1 17.9 13 15.4 1 17.6 12.6 47 5 51 305 6.7 0 7.2 6.7 09/05/2005 11:40:00 15.7 1.1 18.3 12.6 15.5 1.2 18.3 11.5 43 4 36 305 6.6 0.1 7.2 6.4 09/05/2005 11:50:00 15.1 1.3 18.3 12.2 14.9 1.3 17.9 11.1 47 5 43 305 6.7 0.1 7.2 6.4 09/05/2005 12:00:00 15.6 0.9 17.6 13 15.3 1.1 17.6 12.2 47 4 50 305 6.7 0.1 7.4 6.4 09/05/2005 12:10:00 15.4 0.9 17.9 12.2 15.2 1 17.6 12.2 45 5 43 305 6.7 0.1 7.2 6.4 09/05/2005 12:20:00 15.5 1.1 17.6 12.6 15.2 1.2 17.2 11.5 45 4 43 305 6.7 0.1 7.2 6.7 09/05/2005 12:30:00 15.7 1.2 17.9 12.2 15.3 1.2 17.9 11.8 48 4 51 305 6.8 0 7.2 6.7 09/05/2005 12:40:00 15.6 1.2 17.9 12.2 15.1 1.3 18.3 11.5 48 5 43 305 6.9 0.1 7.4 6.7 09/05/2005 12:50:00 15.2 1 17.6 12.6 14.9 1.1 17.6 11.5 49 5 51 305 6.9 0 7.4 6.9 09/05/2005 13:00:00 14.4 1.1 17.2 11.5 14.1 1.2 16.8 11.1 49 6 46 305 7 0 7.4 6.9 09/05/2005 13:10:00 14.4 1.1 16.4 11.5 14.2 1.2 16.8 11.1 49 5 48 305 6.9 0 7.4 6.7 09/05/2005 13:20:00 15.3 1.1 17.6 11.8 14.9 1.3 17.6 11.1 48 5 46 305 6.9 0 7.2 6.7 09/05/2005 13:30:00 15.5 1 17.9 12.6 15.1 1.1 17.6 12.2 47 4 42 305 7 0 7.2 6.9 09/05/2005 13:40:00 15.3 1.2 17.9 12.2 15 1.3 17.9 11.5 46 4 43 305 7 0 7.4 6.9 09/05/2005 13:50:00 15.3 1.1 17.2 11.1 15 1.2 17.2 11.1 45 4 40 305 7.2 0.1 7.4 6.9 09/05/2005 14:00:00 15.9 1.1 17.9 12.6 15.6 1.2 17.9 11.8 44 4 44 305 7.2 0 7.4 7.2 09/05/2005 14:10:00 15.7 1.2 17.9 12.6 15.4 1.3 17.9 11.1 45 4 47 305 7 0 7.4 6.9 09/05/2005 14:20:00 16.2 1.2 18.7 13 15.9 1.2 18.3 11.8 45 5 43 305 7.2 0 7.4 7.2 09/05/2005 14:30:00 16.6 0.9 18.7 12.6 16.3 1 18.3 11.8 45 4 45 305 7.2 0 7.4 7.2 09/05/2005 14:40:00 16.4 1.1 18.7 11.8 16 1.2 18.7 12.2 44 5 43 305 7.3 0 7.7 7.2 09/05/2005 14:50:00 16.5 1.3 18.7 12.6 16.1 1.3 18.7 13 45 4 45 305 7.4 0 7.7 7.2 09/05/2005 15:00:00 16.6 1.3 19.5 13 16.3 1.4 19.1 12.6 46 4 45 305 7.3 0.1 7.7 7.2 09/05/2005 15:10:00 16.5 1.1 19.1 13.3 16.3 1.2 18.7 13 42 4 42 305 7.3 0 7.7 7.2 09/05/2005 15:20:00 16 0.9 18.3 13.3 16 1 17.9 12.6 41 4 46 305 7.1 0 7.4 6.9 09/05/2005 15:30:00 16 1 18.3 12.6 15.8 1 17.9 13 42 5 41 305 7.2 0.1 7.7 6.9 09/05/2005 15:40:00 16.2 1.3 18.7 13 15.9 1.4 18.7 12.2 43 5 48 305 7.3 0 7.7 7.2 09/05/2005 15:50:00 16.2 1 18.3 12.6 16.1 1.2 18.3 12.2 42 4 45 305 7.3 0 7.9 7.2 09/05/2005 16:00:00 15.7 1 17.9 11.8 15.6 1 17.9 12.6 41 4 39 305 7.2 0 7.7 7.2 09/05/2005 16:10:00 15.3 1.1 17.6 12.2 15.2 1.1 17.6 11.8 38 4 40 305 7.3 0 7.9 7.2 09/05/2005 16:20:00 14.8 1.1 17.2 11.8 14.7 1.2 17.2 11.5 37 4 38 305 7.2 0.1 7.7 7.2 09/05/2005 16:30:00 14.7 1 16.8 11.8 14.5 1.2 16.8 11.5 36 4 35 305 7.2 0.1 7.7 7.2 09/05/2005 16:40:00 14.9 1 17.2 12.2 14.8 1 17.6 11.1 37 4 36 305 7.1 0 7.4 7.2 09/05/2005 16:50:00 14.6 1.3 17.2 11.5 14.3 1.3 17.6 10.7 39 5 36 305 7.3 0 7.7 7.2 09/05/2005 17:00:00 14.6 1.2 16.8 11.1 14.5 1.4 17.2 10.7 37 4 39 305 7.2 0 7.4 6.9 09/05/2005 17:10:00 14 1 16.4 11.1 14 1 16.4 10.7 36 4 31 305 7.2 0.1 7.7 7.2 09/05/2005 17:20:00 14.5 1.2 17.2 11.1 14.3 1.3 16.8 10.7 36 5 42 305 7 0 7.4 6.9 09/05/2005 17:30:00 14.2 1 16.4 11.5 14 1.1 16.4 11.1 35 4 29 305 7 0 7.4 6.9 09/05/2005 17:40:00 14.1 1 16.8 11.1 13.9 1 16.8 10.3 34 4 40 305 6.9 0 7.2 6.7 09/05/2005 17:50:00 14.2 1 16.8 11.8 14.1 1.1 16.8 11.5 36 4 36 305 6.8 0 7.2 6.7 09/05/2005 18:00:00 14.7 1 16.8 11.5 14.5 1.1 17.2 10.3 36 4 41 305 6.9 0 7.2 6.9 09/05/2005 18:10:00 14.4 1.2 16.8 11.1 14.4 1.3 17.2 10.7 38 4 42 305 6.9 0 7.2 6.9 09/05/2005 18:20:00 14.6 1.1 16.8 11.5 14.4 1.1 16.8 11.1 35 5 29 305 6.8 0 7.2 6.7 09/05/2005 18:30:00 14.4 1.1 16.8 11.5 14.3 1.1 17.6 10.3 37 5 39 305 6.8 0 7.2 6.7 09/05/2005 18:40:00 14.7 1.1 17.6 12.2 14.5 1.2 16.8 10.7 35 4 33 305 6.8 0 7.2 6.7 09/05/2005 18:50:00 15.3 1.3 18.3 11.5 15.1 1.4 17.9 11.5 35 4 42 305 6.7 0.1 7.2 6.4 09/05/2005 19:00:00 15.7 1.1 18.7 11.8 15.7 1.1 18.7 12.2 36 4 34 305 6.7 0 6.9 6.4 09/05/2005 19:10:00 15 1.2 17.9 11.5 14.8 1.2 17.6 11.5 33 4 33 305 6.6 0 6.9 6.4 09/05/2005 19:20:00 14.6 1.2 17.2 11.5 14.5 1.3 17.2 11.5 33 5 33 305 6.6 0 6.9 6.4 09/05/2005 19:30:00 15.1 1.2 17.6 12.2 14.9 1.4 17.9 11.1 34 4 35 305 6.5 0 6.7 6.4 09/05/2005 19:40:00 15.1 1.3 18.3 11.8 15 1.3 18.3 11.5 34 4 31 305 6.5 0 6.7 6.4 09/05/2005 19:50:00 15.6 1.1 18.3 11.5 15.5 1.2 17.9 11.8 35 4 37 305 6.5 0 6.4 6.4 09/05/2005 20:00:00 15.2 1.4 18.3 11.8 15 1.5 19.1 11.1 35 5 39 305 6.5 0 6.7 6.1 09/05/2005 20:10:00 15 1.5 18.3 10.7 14.8 1.6 18.3 9.9 35 5 32 305 6.4 0 6.4 6.1 09/05/2005 20:20:00 16 1.3 18.7 11.8 15.7 1.4 18.7 11.5 33 4 33 305 6.3 0 6.4 6.1 09/05/2005 20:30:00 15.5 1.1 18.3 12.2 15.3 1.1 18.7 12.2 34 5 38 305 6.2 0 6.4 6.1 09/05/2005 20:40:00 15.4 1.2 17.9 12.2 15.3 1.3 17.9 11.8 33 4 36 305 6.1 0.1 6.4 5.9 09/05/2005 20:50:00 15.3 1.1 18.7 12.2 15.2 1.3 19.1 11.8 33 4 30 305 6 0.1 6.7 5.9 09/05/2005 21:00:00 15.1 1.3 17.9 11.5 15 1.4 17.9 10.3 33 5 33 305 6 0.1 6.7 5.9 09/05/2005 21:10:00 15.3 1.3 17.6 10.3 15.2 1.3 17.9 10.7 32 4 27 305 6 0 6.4 5.9 09/05/2005 21:20:00 15.3 1.2 17.6 12.2 15.3 1.2 17.6 11.8 31 5 34 305 6 0 6.4 5.9 09/05/2005 21:30:00 15 1.3 17.6 11.8 14.8 1.3 17.9 11.8 31 5 26 305 5.9 0 6.4 5.6 09/05/2005 21:40:00 15.6 1 18.3 12.2 15.5 1.2 18.3 12.2 30 4 39 305 5.8 0 6.4 5.6 09/05/2005 21:50:00 15.3 1.1 17.6 12.6 15.2 1.1 17.9 11.8 30 4 25 305 5.9 0 6.4 5.9 09/05/2005 22:00:00 15.4 1.2 17.9 12.2 15.2 1.3 17.9 11.5 31 4 27 305 5.8 0 5.9 5.6 09/05/2005 22:10:00 15.2 1 17.6 12.6 15.1 1 17.9 12.2 28 4 27 305 5.8 0 5.9 5.6 09/05/2005 22:20:00 15 1.2 17.2 11.1 14.9 1.1 17.2 11.1 29 4 23 305 5.8 0 5.9 5.6 09/05/2005 22:30:00 15 1 17.2 12.2 15 1 17.6 12.2 28 4 25 305 5.8 0 5.9 5.6 09/05/2005 22:40:00 14.7 1 17.2 11.5 14.6 1.1 16.8 11.5 29 5 29 305 5.6 0 5.9 5.6 09/05/2005 22:50:00 14.3 1 16.8 11.8 14.1 1.1 17.2 11.1 29 4 30 305 5.6 0 5.9 5.6 09/05/2005 23:00:00 14.1 1.3 16.8 11.1 13.9 1.4 17.2 10.3 29 4 27 305 5.7 0 5.9 5.6 09/05/2005 23:10:00 14 1.1 16.4 10.7 13.9 1.2 16.8 10.3 29 5 29 305 5.6 0 5.9 5.6 09/05/2005 23:20:00 14.3 1.1 17.2 11.5 14.1 1.1 16.8 11.1 27 5 26 305 5.6 0 5.6 5.4 09/05/2005 23:30:00 14.7 1 17.2 11.1 14.7 1.1 17.2 11.5 25 4 22 305 5.6 0 5.9 5.4 09/05/2005 23:40:00 14.3 1 16.8 11.8 14.2 1 16.4 11.8 26 5 27 305 5.5 0 5.6 5.4 09/05/2005 23:50:00 13.9 1.1 16.4 11.1 13.9 1.1 16.4 10.7 23 5 22 305 5.5 0 5.6 5.4 09/06/2005 00:00:00 13.4 1.1 15.6 10.3 13.5 1.1 15.6 10.7 23 5 22 305 5.4 0 5.6 5.4 09/06/2005 00:10:00 13.2 0.9 15.3 10.7 13.3 1 15.3 11.1 23 4 17 305 5.4 0 5.6 5.4 09/06/2005 00:20:00 13.3 1.2 16.1 10.3 13.3 1.3 16.4 10.7 23 4 23 305 5.4 0 5.6 5.2 09/06/2005 00:30:00 13.3 0.9 15.3 10.7 13.2 1 15.6 10.3 23 4 26 305 5.4 0 5.6 5.4 09/06/2005 00:40:00 12.9 1 14.9 9.9 13 1.1 15.6 9.5 22 5 27 305 5.4 0 5.6 5.4 09/06/2005 00:50:00 13.5 1.1 16.1 11.1 13.5 1.2 16.1 10.3 23 4 31 305 5.4 0 5.6 5.4 09/06/2005 01:00:00 13 1 15.6 10.7 13.1 1.1 15.6 10.7 21 4 18 305 5.4 0 5.6 5.4 09/06/2005 01:10:00 13.6 0.8 15.6 11.1 13.7 0.9 15.6 10.3 21 3 19 305 5.4 0 5.6 5.4 09/06/2005 01:20:00 13.7 1.1 15.6 10.7 13.8 1.1 16.1 10.3 22 3 24 305 5.4 0 5.6 5.4 09/06/2005 01:30:00 13.5 1 16.1 10.3 13.5 1.1 16.4 10.7 18 4 19 305 5.3 0 5.4 5.2 09/06/2005 01:40:00 13.5 1 15.6 10.7 13.6 1 16.1 10.7 20 4 18 305 5.3 0 5.4 5.2 09/06/2005 01:50:00 13.9 1 15.6 10.3 13.9 1.1 16.1 10.3 18 4 16 305 5.3 0 5.4 5.2 09/06/2005 02:00:00 13.3 0.8 15.3 11.1 13.4 0.8 15.3 10.7 19 4 17 305 5.3 0 5.4 5.2 09/06/2005 02:10:00 12.9 1 15.6 10.7 12.9 1 15.6 10.3 18 4 18 305 5.3 0 5.4 5.2 09/06/2005 02:20:00 13.1 0.9 15.3 10.7 13.1 1 16.1 10.7 18 4 19 305 5.2 0 5.4 5.2 09/06/2005 02:30:00 13.5 0.8 15.3 11.5 13.6 1 15.6 11.1 20 4 12 305 5.2 0 5.4 5.2 09/06/2005 02:40:00 12.7 1 14.9 10.3 12.8 1 14.9 9.9 18 4 15 305 5.3 0 5.4 5.2 09/06/2005 02:50:00 12.7 1.1 14.9 9.9 12.8 1.2 15.3 9.9 17 4 12 305 5.3 0 5.6 5.2 09/06/2005 03:00:00 13.2 0.8 15.3 10.3 13.3 1 15.6 10.7 16 4 14 305 5.3 0 5.4 5.2 09/06/2005 03:10:00 13.2 1.1 15.3 10.7 13.4 1.2 16.1 10.3 17 3 21 305 5.4 0 5.6 5.4 09/06/2005 03:20:00 13.2 0.9 14.9 10.3 13.3 1 15.3 9.9 17 4 21 305 5.4 0 5.6 5.4 09/06/2005 03:30:00 13.1 0.9 14.9 10.7 13.3 0.9 15.6 11.1 16 4 13 305 5.4 0 5.6 5.4 09/06/2005 03:40:00 12.7 1 14.5 9.9 12.8 1.1 14.9 9.1 15 4 12 305 5.4 0 5.6 5.4 09/06/2005 03:50:00 12.8 0.9 15.3 10.3 13 1 15.3 10.3 14 4 9 305 5.4 0 5.6 5.4 09/06/2005 04:00:00 12.8 0.8 14.5 10.3 13.1 0.9 14.9 10.7 13 4 17 305 5.4 0 5.6 5.4 09/06/2005 04:10:00 13 0.9 14.9 9.9 13.2 0.9 15.6 9.9 15 4 16 305 5.4 0 5.6 5.4 09/06/2005 04:20:00 13 0.9 14.9 10.3 13.1 1 15.6 10.7 15 4 13 305 5.5 0 5.6 5.4 09/06/2005 04:30:00 12.8 0.8 14.5 9.9 13 0.9 14.9 10.3 13 3 11 305 5.5 0 5.6 5.4 09/06/2005 04:40:00 12.7 1 14.5 10.3 12.9 1 15.3 10.7 15 3 16 305 5.4 0 5.6 5.4 09/06/2005 04:50:00 12.2 0.8 13.7 10.3 12.3 1 14.1 9.5 14 4 18 305 5.5 0 5.6 5.4 09/06/2005 05:00:00 12.6 0.6 14.1 11.1 12.8 0.7 14.5 11.1 13 4 16 305 5.4 0 5.6 5.4 09/06/2005 05:10:00 12.4 0.8 14.1 9.5 12.6 0.8 14.5 9.5 15 4 12 305 5.5 0 5.6 5.4 09/06/2005 05:20:00 12.3 0.8 14.5 9.9 12.5 0.8 14.5 9.9 14 4 8 305 5.5 0 5.6 5.4 09/06/2005 05:30:00 12.6 0.8 14.5 9.9 12.8 0.9 14.5 10.3 13 4 14 305 5.5 0 5.6 5.4 09/06/2005 05:40:00 12 0.8 14.1 9.9 12.2 0.9 14.9 9.5 11 4 11 305 5.5 0 5.6 5.4 09/06/2005 05:50:00 11.8 1 14.1 9.1 12.1 1 14.5 9.5 6 5 7 305 5.4 0 5.6 5.2 09/06/2005 06:00:00 11.7 0.8 13.7 9.1 11.9 0.9 14.1 9.5 6 4 12 305 5.2 0 5.4 5.2 09/06/2005 06:10:00 11.5 0.8 13.3 9.5 11.7 0.8 13.3 9.1 5 5 7 305 5.2 0 5.4 4.9 09/06/2005 06:20:00 11.8 1 14.1 8.8 12.1 1 14.5 9.5 8 4 9 305 5.1 0 5.4 4.9 09/06/2005 06:30:00 11.2 0.7 13 9.5 11.6 0.8 13.3 9.5 4 4 1 305 5 0 5.4 4.9 09/06/2005 06:40:00 11.5 0.6 13 9.9 11.9 0.7 13.7 9.5 4 5 357 305 4.9 0 5.2 4.9 09/06/2005 06:50:00 11.1 0.7 12.6 9.1 11.4 0.7 13 9.1 4 4 5 305 4.8 0 4.9 4.9 09/06/2005 07:00:00 11.1 0.6 12.6 9.5 11.4 0.7 13 9.5 4 4 8 305 4.8 0 4.9 4.7 09/06/2005 07:10:00 10.6 0.7 12.2 8.4 10.9 0.8 12.6 8.4 1 4 5 305 4.8 0 4.9 4.7 09/06/2005 07:20:00 10.6 0.7 12.2 8.8 11 0.8 12.6 8.8 1 4 5 305 4.8 0 4.9 4.7 09/06/2005 07:30:00 10.5 0.5 11.8 8.8 10.9 0.6 12.2 8.8 2 5 0 305 4.8 0 4.9 4.7 09/06/2005 07:40:00 10.6 0.7 12.6 8 10.9 0.8 13.7 8.4 3 5 7 305 4.8 0 4.9 4.7 09/06/2005 07:50:00 10.4 0.8 12.2 8.8 10.8 0.9 13 8.8 2 5 2 305 4.8 0 4.9 4.7 09/06/2005 08:00:00 10.6 0.7 12.2 8.4 10.9 0.8 12.6 8.8 2 4 0 305 4.8 0 4.9 4.7 09/06/2005 08:10:00 10.3 0.8 12.2 8.8 10.6 0.8 12.6 8.4 4 5 358 305 4.8 0 5.2 4.9 09/06/2005 08:20:00 10.3 0.6 11.8 8.4 10.8 0.6 12.2 8.8 3 4 3 305 4.8 0 5.2 4.9 09/06/2005 08:30:00 9.8 0.6 11.1 7.6 10 0.7 11.8 7.2 0 4 0 305 4.9 0 5.2 4.9 09/06/2005 08:40:00 9.4 0.6 11.1 7.6 9.7 0.7 11.8 7.6 359 5 358 305 5 0.1 5.2 4.9 09/06/2005 08:50:00 9.3 0.6 11.1 7.2 9.7 0.6 11.1 7.6 354 4 5 305 5 0 5.2 4.9 09/06/2005 09:00:00 9.1 0.6 10.7 7.6 9.5 0.7 11.1 8 354 4 354 305 4.9 0 5.2 4.9 09/06/2005 09:10:00 9.1 0.6 10.7 6.8 9.3 0.6 11.1 7.2 354 4 357 305 5.1 0 5.4 4.9 09/06/2005 09:20:00 8.5 0.5 9.9 7.2 8.9 0.5 9.9 6.8 353 4 356 305 5 0 5.4 4.9 09/06/2005 09:30:00 8 0.6 9.5 6.5 8.3 0.7 9.9 6.5 352 5 349 305 5.1 0 5.4 4.9 09/06/2005 09:40:00 8.1 0.5 9.5 6.1 8.4 0.7 9.9 6.5 353 4 350 305 5.2 0 5.4 4.9 09/06/2005 09:50:00 8.3 0.7 9.9 6.5 8.6 0.7 10.3 6.8 359 4 358 305 5.3 0 5.4 5.2 09/06/2005 10:00:00 7.8 0.6 9.1 6.1 8.1 0.6 9.5 6.5 355 5 350 305 5.3 0 5.4 5.2 09/06/2005 10:10:00 7.7 0.5 8.8 6.1 7.9 0.6 9.1 6.1 350 4 351 305 5.3 0 5.6 5.2 09/06/2005 10:20:00 7.5 0.5 8.8 6.5 7.8 0.5 9.1 6.1 349 4 347 305 5.3 0 5.6 5.2 09/06/2005 10:30:00 7.7 0.6 9.1 6.5 8.1 0.7 9.9 5.7 353 4 354 305 5.3 0 5.6 5.2 09/06/2005 10:40:00 7.7 0.5 9.1 6.5 7.9 0.6 9.1 6.1 354 4 356 305 5.5 0 5.6 5.4 09/06/2005 10:50:00 7.7 0.5 9.1 6.1 8 0.5 9.5 6.5 348 5 358 305 5.5 0 5.6 5.4 09/06/2005 11:00:00 7.5 0.5 8.8 6.1 7.8 0.6 9.1 6.1 351 4 347 305 5.5 0 5.6 5.4 09/06/2005 11:10:00 7.5 0.5 8.8 5.7 7.8 0.5 9.1 6.5 350 4 347 305 5.4 0 5.9 5.4 09/06/2005 11:20:00 7.6 0.5 8.8 5.7 8 0.6 9.1 5.3 345 4 353 305 5.5 0 5.6 5.4 09/06/2005 11:30:00 7.4 0.5 8.8 6.1 7.6 0.6 8.8 5.7 345 4 348 305 5.5 0 5.9 5.4 09/06/2005 11:40:00 7 0.5 8 5.3 7.3 0.6 8.8 5.7 347 4 355 305 5.6 0 6.1 5.4 09/06/2005 11:50:00 6.8 0.5 8.4 4.9 7.1 0.6 8.4 5.3 351 5 348 305 5.6 0.1 6.4 5.4 09/06/2005 12:00:00 6.3 0.5 7.2 4.6 6.5 0.5 7.6 4.9 345 5 352 305 5.7 0 5.9 5.6 09/06/2005 12:10:00 6.1 0.5 7.2 4.6 6.3 0.6 7.6 4.9 344 4 340 305 5.8 0 6.1 5.6 09/06/2005 12:20:00 6.4 0.4 7.2 5.3 6.6 0.5 7.6 4.9 347 3 340 305 5.8 0 6.1 5.6 09/06/2005 12:30:00 6.1 0.4 6.8 4.9 6.4 0.4 7.2 5.3 347 3 351 305 5.8 0 5.9 5.6 09/06/2005 12:40:00 6 0.4 6.8 4.9 6.3 0.4 7.2 5.3 345 4 344 305 5.8 0 6.4 5.6 09/06/2005 12:50:00 6.3 0.5 7.2 4.6 6.5 0.5 7.2 4.9 346 3 350 305 5.8 0 6.1 5.6 09/06/2005 13:00:00 6.2 0.4 6.8 4.6 6.4 0.5 7.2 4.6 351 3 349 305 6 0.2 6.7 5.6 09/06/2005 13:10:00 5.9 0.5 6.8 4.2 6.1 0.6 7.2 4.2 350 4 350 305 6.1 0.1 6.9 5.9 09/06/2005 13:20:00 5.6 0.5 6.8 4.2 5.9 0.5 7.2 4.6 348 4 347 305 6.1 0.1 6.7 5.9 09/06/2005 13:30:00 5 0.5 6.1 3.8 5.3 0.5 6.1 3.8 346 4 343 305 5.9 0 6.4 5.9 09/06/2005 13:40:00 5.1 0.5 6.1 3.8 5.3 0.5 6.5 3.8 346 4 348 305 6 0 6.4 5.9 09/06/2005 13:50:00 5.1 0.5 6.1 3.8 5.3 0.6 6.1 3.8 342 4 342 305 6 0 6.4 5.9 09/06/2005 14:00:00 4.6 0.5 5.7 3.4 4.9 0.6 6.1 3.4 349 6 349 305 6.1 0.1 6.9 5.9 09/06/2005 14:10:00 4.5 0.5 5.3 3 4.7 0.5 5.7 3 348 6 337 305 6.2 0 6.9 5.9 09/06/2005 14:20:00 4.6 0.4 5.7 3.8 4.8 0.5 6.1 3.8 344 7 336 305 6 0.1 6.4 5.9 09/06/2005 14:30:00 4.4 0.5 5.7 3 4.6 0.5 5.7 3.4 343 4 343 305 6 0 6.4 5.9 09/06/2005 14:40:00 4 0.4 4.9 2.6 4.2 0.4 4.9 3 338 7 339 305 6 0.1 6.7 5.9 09/06/2005 14:50:00 4 0.4 4.9 3 4.2 0.4 4.9 3 339 7 330 305 6.4 0.2 7.2 5.9 09/06/2005 15:00:00 4 0.5 5.3 2.6 4.3 0.4 5.7 3 349 6 355 305 6.4 0.1 7.2 6.1 09/06/2005 15:10:00 4.2 0.4 4.9 3 4.4 0.4 5.3 3.4 346 6 343 305 6.5 0 6.9 6.1 09/06/2005 15:20:00 4.4 0.4 5.3 3 4.7 0.4 5.7 3.4 342 5 349 305 6.5 0.1 7.2 6.1 09/06/2005 15:30:00 4.5 0.4 5.7 3 4.7 0.4 5.7 3.4 342 6 336 305 6.5 0 6.9 6.1 09/06/2005 15:40:00 4.1 0.4 4.9 3 4.3 0.4 5.3 3 340 7 345 305 6.5 0 6.9 6.1 09/06/2005 15:50:00 3.8 0.4 4.6 2.6 4 0.4 4.9 2.6 334 7 338 305 6.5 0 6.7 6.4 09/06/2005 16:00:00 3.8 0.4 4.6 2.6 4 0.4 4.9 2.6 330 8 329 305 6.5 0 6.9 6.4 09/06/2005 16:10:00 3.4 0.4 4.9 2.3 3.7 0.4 4.9 2.6 321 9 319 305 6.6 0 6.9 6.4 09/06/2005 16:20:00 3.5 0.4 4.6 2.3 3.7 0.4 4.6 2.6 316 10 319 305 6.7 0 6.9 6.4 09/06/2005 16:30:00 3 0.4 4.6 1.9 3.2 0.4 4.2 2.3 317 8 318 305 6.8 0 7.2 6.7 09/06/2005 16:40:00 2.7 0.4 3.4 1.5 2.9 0.4 4.2 1.9 321 8 322 305 6.8 0 7.2 6.9 09/06/2005 16:50:00 2.8 0.5 4.2 1.5 2.9 0.4 4.6 1.5 311 9 303 305 7 0 7.2 6.9 09/06/2005 17:00:00 2.9 0.5 4.2 1.9 3 0.4 4.2 1.9 296 9 285 305 7 0 7.2 6.9 09/06/2005 17:10:00 2.6 0.6 4.6 1.5 2.6 0.6 4.2 1.1 285 13 269 305 7 0 7.2 6.9 09/06/2005 17:20:00 2.7 0.5 4.2 1.5 2.5 0.6 4.6 1.1 280 13 287 305 6.9 0 7.2 6.7 09/06/2005 17:30:00 3.1 0.5 4.2 1.9 2.9 0.6 4.2 1.5 274 10 252 305 6.8 0 6.9 6.7 09/06/2005 17:40:00 3 0.5 4.2 1.5 2.7 0.5 3.8 1.5 268 13 275 305 6.7 0 6.9 6.4 09/06/2005 17:50:00 3 0.5 4.6 1.9 2.8 0.5 4.2 1.5 255 11 256 305 6.6 0.1 6.9 6.4 09/06/2005 18:00:00 3.1 0.5 4.2 1.5 2.9 0.6 4.6 1.1 256 10 251 305 6.7 0 6.9 6.4 09/06/2005 18:10:00 2.8 0.6 4.2 1.1 2.6 0.6 4.2 1.5 249 13 239 305 6.7 0 6.9 6.4 09/06/2005 18:20:00 2.9 0.4 4.2 1.9 2.9 0.5 3.8 1.5 231 10 241 305 6.9 0 7.2 6.9 09/06/2005 18:30:00 3.1 0.4 4.2 1.9 3 0.4 3.8 1.9 225 10 228 305 6.9 0 7.2 6.9 09/06/2005 18:40:00 3.1 0.4 4.2 1.5 3.2 0.4 4.6 2.3 217 9 218 305 7 0 7.2 6.9 09/06/2005 18:50:00 3.2 0.5 4.6 1.5 3.2 0.4 4.6 2.3 213 9 210 305 7 0 7.2 6.9 09/06/2005 19:00:00 2.9 0.5 4.2 1.9 3 0.5 4.6 1.9 215 12 227 305 7.3 0 7.7 7.2 09/06/2005 19:10:00 3.1 0.8 4.9 1.5 2.9 0.6 4.6 1.5 253 28 279 305 7.7 0.1 8.2 7.4 09/06/2005 19:20:00 4.3 0.6 5.7 2.6 3.9 0.6 5.3 2.3 283 8 287 305 8.1 0 8.2 7.9 09/06/2005 19:30:00 4.5 0.6 6.1 2.6 4.4 0.6 6.1 2.6 288 9 286 305 8.1 0 8.2 7.9 09/06/2005 19:40:00 5.3 0.7 6.8 3.4 5 0.7 6.8 2.6 292 7 295 305 8.1 0 8.2 7.9 09/06/2005 19:50:00 5.3 0.6 6.5 3.8 5.1 0.7 6.8 3.4 293 6 294 305 7.9 0 8.2 7.9 09/06/2005 20:00:00 4.6 0.7 6.5 3 4.2 0.8 6.1 1.9 290 9 292 305 7.9 0 7.9 7.9 09/06/2005 20:10:00 4.2 0.6 6.1 2.6 3.9 0.6 5.3 2.6 287 7 284 305 7.7 0 7.9 7.7 09/06/2005 20:20:00 4.4 0.6 6.1 3 4 0.6 5.7 1.9 285 8 287 305 7.5 0 7.7 7.4 09/06/2005 20:30:00 4.5 0.5 6.1 3.4 4 0.5 5.7 2.3 289 9 282 305 7.3 0 7.7 7.4 09/06/2005 20:40:00 4.5 0.7 6.5 2.3 4 0.7 6.1 2.3 285 8 284 305 7.2 0 7.4 7.2 09/06/2005 20:50:00 5.1 0.7 6.8 3 4.6 0.7 7.2 2.6 288 8 285 305 6.9 0 7.2 6.9 09/06/2005 21:00:00 5.6 0.7 7.2 3.4 5 0.7 7.2 3 289 7 298 305 6.7 0 6.9 6.4 09/06/2005 21:10:00 4.7 0.6 6.5 3 4.1 0.6 5.3 2.3 289 10 286 305 6.5 0 6.7 6.1 09/06/2005 21:20:00 4.4 0.6 6.1 3 3.8 0.7 5.7 2.6 287 8 292 305 6.2 0 6.4 6.1 09/06/2005 21:30:00 4.2 0.6 5.3 2.3 3.2 0.7 5.3 1.5 283 9 302 305 6.1 0 6.4 5.9 09/06/2005 21:40:00 4.1 0.7 6.1 1.5 3.2 0.7 5.3 1.5 282 12 291 305 6 0 6.1 5.9 09/06/2005 21:50:00 4.5 0.8 6.5 2.3 3.6 0.8 6.5 1.9 279 10 290 305 6 0 6.1 5.9 09/06/2005 22:00:00 4.6 0.7 6.8 2.3 3.7 0.8 6.5 1.9 280 9 288 305 6 0 6.1 5.9 09/06/2005 22:10:00 4.6 0.7 6.8 2.6 3.7 0.8 6.1 1.9 278 10 285 305 6 0 5.9 5.9 09/06/2005 22:20:00 3.6 0.8 6.1 1.5 2.6 0.6 4.2 1.1 267 11 273 305 5.9 0 5.9 5.9 09/06/2005 22:30:00 3.4 0.8 5.3 1.5 2.6 0.6 4.6 1.1 266 11 272 305 5.8 0 5.9 5.6 09/06/2005 22:40:00 4 0.8 6.5 2.3 3.1 0.6 5.3 1.9 272 11 273 305 5.8 0 5.9 5.6 09/06/2005 22:50:00 4.7 0.9 7.2 2.6 3.7 0.9 6.1 1.9 275 10 282 305 5.8 0 5.9 5.6 09/06/2005 23:00:00 5.3 0.6 6.5 3.8 4.2 0.7 6.1 2.6 278 8 283 305 5.9 0 5.9 5.9 09/06/2005 23:10:00 5.1 0.8 7.2 2.6 4 0.8 6.1 1.5 276 8 275 305 5.9 0 5.9 5.9 09/06/2005 23:20:00 4.8 0.8 7.2 3 3.7 0.8 6.1 1.9 277 9 284 305 5.8 0 5.9 5.9 09/06/2005 23:30:00 4.3 0.9 6.8 2.3 3.4 0.9 5.7 1.5 275 12 285 305 5.8 0 5.9 5.6 09/06/2005 23:40:00 4.3 0.8 6.5 2.6 3.2 0.7 5.3 1.9 275 9 280 305 5.7 0 5.9 5.6 09/06/2005 23:50:00 4.4 0.8 6.8 2.6 3.3 0.7 4.9 1.5 273 9 283 305 5.6 0 5.9 5.6 09/07/2005 00:00:00 4.4 0.6 6.1 2.6 3.3 0.6 5.3 1.9 269 9 254 305 5.6 0 6.1 5.4 09/07/2005 00:10:00 4.3 0.8 6.1 2.6 3.3 0.7 4.9 1.9 268 10 273 305 5.5 0 5.6 5.4 09/07/2005 00:20:00 4.7 0.8 6.5 3 3.6 0.7 5.7 1.9 269 9 270 305 5.5 0 5.6 5.4 09/07/2005 00:30:00 4.4 0.8 6.1 1.5 3.4 0.7 4.9 1.5 269 11 268 305 5.4 0 5.6 5.4 09/07/2005 00:40:00 4.8 0.7 6.8 2.6 3.6 0.7 5.7 1.5 269 8 258 305 5.5 0 5.6 5.4 09/07/2005 00:50:00 5.3 0.7 6.8 3.4 4.1 0.7 5.7 2.3 271 8 275 305 5.5 0 5.6 5.4 09/07/2005 01:00:00 5.1 0.8 7.2 2.6 3.9 0.8 5.7 1.9 271 8 271 305 5.5 0 5.6 5.4 09/07/2005 01:10:00 5.5 0.7 7.6 3.4 4.3 0.7 6.8 2.3 274 7 272 305 5.5 0 5.6 5.4 09/07/2005 01:20:00 6.2 0.8 8 3.4 4.9 0.7 6.5 3 275 7 286 305 5.5 0 5.6 5.4 09/07/2005 01:30:00 6.2 0.7 8 3.8 4.8 0.7 6.8 2.6 275 7 270 305 5.5 0 5.6 5.4 09/07/2005 01:40:00 6.4 0.7 8 3.8 5.1 0.7 7.6 3 276 7 278 305 5.5 0 5.6 5.4 09/07/2005 01:50:00 6 0.7 7.6 3.8 4.8 0.7 6.8 3 279 8 276 305 5.5 0 5.6 5.4 09/07/2005 02:00:00 6.2 0.7 7.6 4.2 5 0.8 7.2 3.4 279 7 285 305 5.4 0 5.6 5.4 09/07/2005 02:10:00 6.2 0.6 8 4.6 4.9 0.7 6.5 3 279 7 279 305 5.4 0 5.6 5.4 09/07/2005 02:20:00 6.1 0.7 8 4.2 4.7 0.7 6.5 3 277 7 286 305 5.4 0 5.6 5.4 09/07/2005 02:30:00 6.4 0.6 8 4.6 5 0.7 6.8 2.6 275 7 274 305 5.5 0 5.6 5.4 09/07/2005 02:40:00 6.1 0.6 8 4.2 4.7 0.6 6.5 3 274 6 264 305 5.4 0 5.6 5.4 09/07/2005 02:50:00 6.5 0.7 8 4.6 5 0.7 6.5 3 275 7 279 305 5.5 0 5.6 5.4 09/07/2005 03:00:00 6.3 0.8 8.4 3.8 4.9 0.8 7.2 3 275 7 277 305 5.5 0 5.6 5.4 09/07/2005 03:10:00 6.5 0.8 8.4 4.2 5.1 0.8 6.8 3 275 6 270 305 5.4 0 5.6 5.4 09/07/2005 03:20:00 7.2 0.8 9.1 4.9 5.6 0.8 7.6 3.8 274 7 269 305 5.5 0 5.6 5.4 09/07/2005 03:30:00 7.3 0.7 8.8 5.3 5.9 0.8 8 3.8 275 7 278 305 5.5 0 5.6 5.4 09/07/2005 03:40:00 6.7 0.8 8.4 4.2 5.4 0.9 7.2 2.6 275 6 277 305 5.5 0 5.6 5.4 09/07/2005 03:50:00 7 0.7 8.8 4.9 5.7 0.8 7.6 3.4 278 6 279 305 5.5 0 5.6 5.4 09/07/2005 04:00:00 6.7 0.8 8.4 4.2 5.3 0.8 7.2 2.6 273 7 272 305 5.5 0 5.6 5.4 09/07/2005 04:10:00 6.7 0.8 8.4 4.6 5.1 0.7 7.2 3 272 7 273 305 5.6 0 5.6 5.4 09/07/2005 04:20:00 6.4 0.7 8.4 4.6 4.9 0.7 6.5 3 269 7 275 305 5.5 0 5.6 5.4 09/07/2005 04:30:00 6.2 0.8 8 3.8 4.7 0.8 6.5 3 268 7 280 305 5.5 0 5.6 5.4 09/07/2005 04:40:00 6.6 0.8 8.8 4.2 5.1 0.7 6.8 3.4 270 7 258 305 5.5 0 5.6 5.4 09/07/2005 04:50:00 6.9 0.7 8.8 4.9 5.2 0.7 7.6 3 269 6 265 305 5.5 0 5.6 5.4 09/07/2005 05:00:00 6.5 0.8 8 4.2 4.9 0.7 6.8 3 267 6 262 305 5.6 0 5.6 5.6 09/07/2005 05:10:00 6.8 0.8 8.8 4.2 5.3 0.7 7.2 3.8 269 6 268 305 5.6 0 5.6 5.6 09/07/2005 05:20:00 7 0.8 8.8 4.6 5.4 0.8 7.2 2.6 270 6 255 305 5.5 0 5.6 5.6 09/07/2005 05:30:00 7.1 0.7 9.1 5.3 5.4 0.8 8 3.8 272 7 278 305 5.6 0 5.6 5.6 09/07/2005 05:40:00 7.3 0.7 9.1 5.3 5.9 0.8 8.4 3.8 275 7 291 305 5.6 0 5.6 5.6 09/07/2005 05:50:00 7 0.8 8.8 3.8 5.6 0.8 8 3.8 273 6 270 305 5.7 0 5.9 5.6 09/07/2005 06:00:00 7.4 0.6 9.1 5.7 6.1 0.8 7.6 3.8 274 7 275 305 5.7 0 5.9 5.6 09/07/2005 06:10:00 7.2 1 9.5 4.6 5.8 1.1 8.4 3 274 6 271 305 5.7 0 5.9 5.6 09/07/2005 06:20:00 5.6 0.7 7.6 3 4.4 0.8 6.8 2.3 267 6 268 305 5.6 0 5.9 5.6 09/07/2005 06:30:00 6 0.7 7.6 3.8 4.7 0.8 6.8 3 268 6 268 305 5.6 0 5.9 5.6 09/07/2005 06:40:00 5.9 0.7 7.2 3.4 4.6 0.7 6.5 2.6 270 7 268 305 5.6 0 5.9 5.6 09/07/2005 06:50:00 6.9 0.9 8.8 4.2 5.3 0.8 7.6 3.4 266 7 269 305 5.6 0 5.9 5.6 09/07/2005 07:00:00 7.1 0.8 8.8 4.6 5.5 0.7 7.2 3.4 268 6 274 305 5.6 0 5.9 5.4 09/07/2005 07:10:00 7.1 0.6 8.4 5.7 5.6 0.7 7.6 3.4 267 5 265 305 5.6 0 5.9 5.4 09/07/2005 07:20:00 6.5 0.7 8 4.6 4.9 0.8 6.8 3 269 6 268 305 5.5 0 5.6 5.4 09/07/2005 07:30:00 7.1 0.7 8.8 4.9 5.7 0.7 8 3.8 268 7 270 305 5.6 0 5.9 5.6 09/07/2005 07:40:00 6.5 0.7 8.4 4.6 5 0.7 6.8 3 266 6 268 305 5.6 0 5.9 5.6 09/07/2005 07:50:00 6.9 0.8 9.1 4.6 5.5 0.8 7.6 3.4 271 6 273 305 5.6 0 5.9 5.6 09/07/2005 08:00:00 6.5 0.7 8.4 4.6 5.4 0.8 7.2 3.4 277 5 268 305 5.6 0 5.9 5.6 09/07/2005 08:10:00 6.3 0.8 8.4 4.2 5 0.8 6.8 3 271 6 271 305 5.6 0 5.9 5.4 09/07/2005 08:20:00 6.1 0.6 7.6 4.2 4.8 0.6 6.5 3 273 6 276 305 5.5 0 5.9 5.4 09/07/2005 08:30:00 6.2 0.7 8 3.8 5 0.7 6.8 3 272 6 264 305 5.6 0 5.9 5.6 09/07/2005 08:40:00 5.2 0.6 6.8 2.6 4.1 0.5 5.7 3 265 5 277 305 5.8 0 6.1 5.6 09/07/2005 08:50:00 5.5 0.7 7.6 3.4 4.3 0.6 6.8 3 267 8 279 305 5.9 0 5.9 5.9 09/07/2005 09:00:00 5.7 0.8 8.4 4.2 4.6 0.7 6.5 2.6 270 6 259 305 6 0 6.1 5.9 09/07/2005 09:10:00 5.8 0.9 7.6 3.4 4.6 0.8 6.8 3 265 6 261 305 6 0 6.1 5.9 09/07/2005 09:20:00 5.2 0.8 7.2 2.6 4.5 0.7 6.5 2.6 258 6 265 305 6 0 6.1 5.9 09/07/2005 09:30:00 6 0.8 7.6 3.8 5 0.7 6.8 3.4 265 8 263 305 6 0 6.1 5.9 09/07/2005 09:40:00 4.5 0.8 6.8 2.3 3.7 0.7 5.7 1.9 271 7 267 305 6.2 0 6.4 5.9 09/07/2005 09:50:00 4.4 0.6 6.5 2.3 3.6 0.6 4.9 1.5 272 7 268 305 6.6 0 6.9 6.1 09/07/2005 10:00:00 4.4 0.6 5.7 1.9 3.7 0.5 4.9 1.9 270 6 271 305 6.7 0 6.9 6.4 09/07/2005 10:10:00 4.3 0.7 6.1 2.3 3.7 0.6 5.7 1.9 263 8 264 305 6.5 0 6.7 6.4 09/07/2005 10:20:00 4.1 0.6 5.3 2.3 3.6 0.6 5.3 2.3 259 8 254 305 6.6 0 6.9 6.4 09/07/2005 10:30:00 3.8 0.7 5.3 1.9 3.3 0.6 4.9 1.9 260 9 261 305 6.8 0 6.9 6.7 09/07/2005 10:40:00 3.8 0.6 4.9 2.3 3.6 0.6 4.9 2.3 257 9 263 305 6.8 0 6.9 6.7 09/07/2005 10:50:00 3.5 0.6 5.3 1.5 3.3 0.5 4.6 2.3 256 9 249 305 7 0 7.2 6.9 09/07/2005 11:00:00 3.8 0.6 5.3 1.9 3.7 0.6 5.3 2.3 255 9 251 305 7.1 0 7.4 7.2 09/07/2005 11:10:00 4.3 0.7 6.1 2.6 4 0.7 5.7 2.3 257 8 245 305 7.1 0 7.2 7.2 09/07/2005 11:20:00 4.4 0.6 5.7 2.6 4 0.6 5.3 2.3 256 9 275 305 7.2 0.1 7.4 7.2 09/07/2005 11:30:00 4.6 0.6 6.1 2.6 4.1 0.7 5.7 1.9 258 7 261 305 7.3 0 7.7 7.2 09/07/2005 11:40:00 4.4 0.7 6.1 2.6 4.1 0.7 5.7 2.3 259 8 254 305 7.3 0 7.7 7.2 09/07/2005 11:50:00 4.2 0.6 5.7 2.6 3.8 0.7 5.3 2.3 257 8 268 305 7.5 0 7.7 7.4 09/07/2005 12:00:00 4.2 0.7 5.7 2.3 3.8 0.6 5.3 2.6 258 9 248 305 7.7 0 7.9 7.7 09/07/2005 12:10:00 4.2 0.6 6.1 3 3.8 0.6 5.7 1.9 259 9 264 305 7.6 0 7.7 7.4 09/07/2005 12:20:00 4.1 0.6 5.7 1.9 3.7 0.6 5.3 2.3 257 9 248 305 7.8 0 7.9 7.7 09/07/2005 12:30:00 4.1 0.7 5.7 2.3 3.7 0.7 5.7 1.9 258 8 274 305 7.9 0 8.2 7.7 09/07/2005 12:40:00 4.4 0.5 5.7 2.6 4.1 0.6 5.7 1.9 257 6 256 305 7.7 0 7.9 7.7 09/07/2005 12:50:00 4 0.6 5.3 2.3 3.6 0.6 5.7 2.3 254 9 261 305 7.9 0 8.2 7.7 09/07/2005 13:00:00 4 0.6 5.3 2.6 3.8 0.7 5.3 1.9 254 8 246 305 7.9 0 8.2 7.7 09/07/2005 13:10:00 4.1 0.5 5.3 2.6 4 0.5 5.3 2.6 237 13 227 305 7.7 0 7.9 7.7 09/07/2005 13:20:00 4.2 0.5 4.9 3 4.1 0.5 4.9 2.3 226 7 235 305 7.6 0 7.7 7.4 09/07/2005 13:30:00 4 0.4 4.9 2.6 3.9 0.4 4.6 3 231 6 219 305 7.9 0 8.2 7.7 09/07/2005 13:40:00 4.1 0.5 5.3 2.6 3.9 0.5 4.9 2.6 229 6 228 305 8.3 0 8.7 8.2 09/07/2005 13:50:00 4.4 0.5 5.3 3 4.2 0.5 5.3 3 232 7 230 305 8.7 0.1 8.9 8.4 09/07/2005 14:00:00 4.3 0.5 5.7 3 4.2 0.5 5.3 3 227 7 227 305 8.5 0 8.9 8.4 09/07/2005 14:10:00 4.6 0.5 5.7 3.4 4.5 0.5 5.7 3 230 7 236 305 8.8 0 9.2 8.7 09/07/2005 14:20:00 4.3 0.5 5.7 3 4.2 0.5 5.3 3 228 7 230 305 8.7 0.1 8.9 8.4 09/07/2005 14:30:00 4.3 0.5 5.3 3 4.1 0.5 5.3 2.3 220 9 230 305 8.7 0 9.2 8.4 09/07/2005 14:40:00 4.8 0.6 6.5 3 4.7 0.6 5.7 3 226 9 231 305 8.8 0 9.2 8.4 09/07/2005 14:50:00 4.6 0.5 5.7 3.4 4.4 0.5 5.7 3.4 229 8 226 305 8.6 0 8.9 8.4 09/07/2005 15:00:00 4.4 0.6 5.7 2.6 4.2 0.5 5.7 3 237 8 227 305 8.6 0 8.9 8.4 09/07/2005 15:10:00 4 0.6 5.3 2.6 3.9 0.5 4.9 2.6 235 9 242 305 8.8 0 9.2 8.4 09/07/2005 15:20:00 4 0.6 5.3 2.3 3.8 0.5 4.9 2.6 230 8 229 305 8.8 0.1 9.2 8.4 09/07/2005 15:30:00 4.6 0.6 5.7 3 4.5 0.5 5.7 3.4 229 6 223 305 8.9 0.1 9.2 8.7 09/07/2005 15:40:00 4 0.5 5.3 2.3 3.9 0.5 4.9 2.6 230 7 218 305 9 0 9.2 8.7 09/07/2005 15:50:00 4.5 0.5 5.7 3 4.4 0.5 5.7 2.6 234 6 242 305 8.7 0.1 9.2 8.4 09/07/2005 16:00:00 4.2 0.6 5.7 2.6 4.1 0.6 6.1 3 233 8 232 305 8.7 0.1 8.9 8.4 09/07/2005 16:10:00 4.3 0.5 5.7 3 4.1 0.6 5.7 3 231 8 242 305 9 0.1 9.2 8.7 09/07/2005 16:20:00 4.3 0.6 5.7 1.9 4.1 0.6 5.3 2.6 227 8 227 305 9 0 9.2 8.9 09/07/2005 16:30:00 4.9 0.6 6.5 3 4.4 0.5 6.1 3 228 7 227 305 9.1 0 9.2 8.9 09/07/2005 16:40:00 4.6 0.6 6.1 3.4 4.3 0.5 6.1 3 228 8 222 305 9.3 0 9.5 9.2 09/07/2005 16:50:00 5 0.6 6.5 3.4 4.6 0.6 5.7 3.4 226 7 215 305 9.2 0 9.5 9.2 09/07/2005 17:00:00 5 0.5 6.1 3.8 4.6 0.5 6.1 3.4 226 6 231 305 9.2 0 9.5 9.2 09/07/2005 17:10:00 5 0.5 6.5 3.4 4.6 0.5 5.7 3.4 225 6 216 305 9.3 0 9.5 9.2 09/07/2005 17:20:00 5.3 0.5 6.5 3.8 4.9 0.6 6.5 3.4 219 6 217 305 9.1 0 9.2 8.9 09/07/2005 17:30:00 5.2 0.5 6.5 3.8 4.9 0.5 6.1 3.8 218 6 222 305 9 0 9.2 8.9 09/07/2005 17:40:00 5.1 0.5 6.5 3.4 4.7 0.6 6.5 3.4 216 7 217 305 8.8 0 8.9 8.7 09/07/2005 17:50:00 5.1 0.6 6.5 3 4.8 0.6 6.1 3.4 213 6 214 305 8.8 0 8.9 8.7 09/07/2005 18:00:00 5.3 0.4 6.5 3.8 5.1 0.4 6.1 3.8 209 5 218 305 8.6 0 8.9 8.4 09/07/2005 18:10:00 5.5 0.4 6.5 3.8 5.4 0.5 6.8 3.8 210 6 205 305 8.6 0 8.7 8.4 09/07/2005 18:20:00 5.5 0.5 6.5 4.2 5.3 0.5 6.5 3.8 209 6 208 305 8.6 0 8.7 8.4 09/07/2005 18:30:00 5.3 0.5 6.8 3.8 4.9 0.5 6.1 3.4 213 6 192 305 8.5 0 8.7 8.4 09/07/2005 18:40:00 5.4 0.4 6.8 3.8 5.1 0.5 6.5 3.8 206 5 208 305 8.4 0 8.4 8.4 09/07/2005 18:50:00 5.6 0.4 6.8 4.2 5.4 0.5 6.5 3.8 203 5 207 305 8.4 0 8.4 8.2 09/07/2005 19:00:00 5.5 0.5 6.8 4.2 5.2 0.5 6.5 3.8 207 5 210 305 8.4 0 8.4 8.2 09/07/2005 19:10:00 5.6 0.4 6.8 4.2 5.3 0.5 6.1 3.8 211 5 215 305 8.5 0 8.7 8.4 09/07/2005 19:20:00 5.7 0.5 6.8 4.6 5.5 0.5 6.5 4.2 209 5 212 305 8.6 0 8.7 8.4 09/07/2005 19:30:00 5.8 0.3 6.8 4.6 5.6 0.3 6.5 4.6 207 4 208 305 8.6 0 8.7 8.4 09/07/2005 19:40:00 5.3 0.4 6.5 4.2 5.2 0.4 6.1 3.8 200 4 198 305 8.3 0 8.4 8.2 09/07/2005 19:50:00 5.3 0.4 6.1 4.2 5.2 0.4 6.1 3.8 196 4 199 305 8.1 0 8.2 7.9 09/07/2005 20:00:00 5.3 0.4 6.1 3.8 5.2 0.4 6.1 3.8 199 4 199 305 8 0 8.2 7.9 09/07/2005 20:10:00 5.5 0.3 6.5 4.6 5.4 0.4 6.5 4.6 199 4 199 305 7.8 0 7.9 7.7 09/07/2005 20:20:00 5.7 0.4 6.8 4.9 5.5 0.5 6.5 4.2 197 4 201 305 7.7 0 7.9 7.7 09/07/2005 20:30:00 5.4 0.4 6.5 4.6 5.3 0.4 6.1 3.8 199 4 196 305 7.7 0 7.9 7.7 09/07/2005 20:40:00 5.3 0.4 6.5 4.2 5.2 0.4 6.5 4.2 198 4 190 305 7.5 0 7.7 7.4 09/07/2005 20:50:00 5.2 0.4 6.5 3.8 5.2 0.4 6.1 3.4 197 5 201 305 7.4 0 7.7 7.4 09/07/2005 21:00:00 5.3 0.4 6.5 4.2 5.3 0.4 6.5 4.2 199 6 197 305 7.3 0 7.4 7.2 09/07/2005 21:10:00 5.2 0.5 6.8 4.2 5.1 0.5 6.8 3.4 199 6 206 305 7.2 0 7.4 7.2 09/07/2005 21:20:00 5.2 0.5 6.8 4.2 5.2 0.5 6.5 3.8 196 6 205 305 7 0 7.2 7.2 09/07/2005 21:30:00 5.1 0.5 6.1 3.4 5 0.4 6.1 4.2 195 7 194 305 7 0 7.2 7.2 09/07/2005 21:40:00 4.9 0.5 6.1 3.4 4.9 0.5 6.5 3.4 196 6 203 305 7.1 0 7.2 7.2 09/07/2005 21:50:00 4.9 0.8 6.8 3 5 0.7 6.8 3.4 195 8 207 305 7.2 0 7.4 7.2 09/07/2005 22:00:00 4.7 0.7 6.5 2.3 4.9 0.7 6.8 3.4 192 10 197 305 7.3 0 7.4 7.2 09/07/2005 22:10:00 5.1 0.5 6.5 3 5.2 0.6 6.5 3.8 192 8 187 305 7.2 0 7.4 7.2 09/07/2005 22:20:00 5.7 0.5 6.8 4.2 5.6 0.5 6.8 4.2 197 5 200 305 7.2 0 7.4 7.2 09/07/2005 22:30:00 5.5 0.4 6.5 4.2 5.4 0.5 6.5 3.4 198 5 190 305 7.1 0 7.2 7.2 09/07/2005 22:40:00 5.1 0.4 6.1 3.8 5.1 0.4 6.1 3.8 202 6 201 305 7 0 7.2 7.2 09/07/2005 22:50:00 4.9 0.4 6.1 3.8 4.9 0.4 6.1 3.8 202 7 213 305 7 0 7.2 7.2 09/07/2005 23:00:00 4.8 0.4 5.7 3.4 4.7 0.5 6.1 3 205 8 196 305 7 0 7.2 6.9 09/07/2005 23:10:00 4.7 0.4 6.1 3.8 4.6 0.4 5.7 3.4 215 8 209 305 7 0 7.2 6.9 09/07/2005 23:20:00 4.2 0.6 6.1 3 4 0.6 5.3 2.6 226 7 223 305 7 0 7.2 7.2 09/07/2005 23:30:00 4.2 0.6 5.3 1.9 3.9 0.5 4.9 2.6 230 7 232 305 7.2 0.1 7.4 7.2 09/07/2005 23:40:00 4.1 0.4 4.9 3 3.8 0.4 4.6 2.6 226 6 232 305 7.3 0 7.4 7.4 09/07/2005 23:50:00 4.4 0.4 5.3 2.6 4 0.4 4.9 2.6 227 5 231 305 7.5 0 7.7 7.4 09/08/2005 00:00:00 3.8 0.5 4.6 1.9 3.6 0.5 4.6 2.3 220 6 221 305 7.5 0 8.2 7.7 09/08/2005 00:10:00 3.9 0.4 4.6 2.6 3.8 0.5 4.9 2.3 212 10 222 305 7.6 0 7.7 7.7 09/08/2005 00:20:00 4.2 0.5 5.7 3 4.3 0.5 5.7 3 196 8 204 305 7.7 0 7.9 7.7 09/08/2005 00:30:00 4.6 0.5 6.1 3.4 4.6 0.5 5.7 3.4 199 6 202 305 7.8 0 7.9 7.7 09/08/2005 00:40:00 5.5 0.4 7.2 4.6 5.5 0.4 6.8 4.2 202 5 208 305 7.7 0 7.9 7.7 09/08/2005 00:50:00 5.5 0.4 6.8 4.6 5.5 0.4 6.5 4.2 200 5 205 305 7.5 0 7.7 7.4 09/08/2005 01:00:00 5.4 0.5 6.8 3.8 5.5 0.5 6.8 3.4 202 7 212 305 7.3 0 7.7 7.2 09/08/2005 01:10:00 4.8 0.6 6.8 3.8 4.6 0.6 6.8 3 219 8 227 305 7.3 0 7.7 7.4 09/08/2005 01:20:00 4.9 0.6 6.8 3.8 4.5 0.5 6.1 3 219 8 223 305 7.3 0 7.7 7.4 09/08/2005 01:30:00 5.1 0.4 6.1 3.8 4.6 0.5 5.7 3 219 6 223 305 7.2 0.1 7.4 7.2 09/08/2005 01:40:00 5.7 0.6 6.8 3.8 5.1 0.6 6.5 3.4 230 5 226 305 7.4 0 7.7 7.2 09/08/2005 01:50:00 5.8 0.5 7.6 4.6 5.3 0.6 6.8 3.8 227 6 238 305 7.6 0 7.9 7.4 09/08/2005 02:00:00 5.7 0.4 6.8 4.2 5.2 0.6 6.5 3.4 224 6 228 305 7.7 0 7.9 7.7 09/08/2005 02:10:00 5.3 0.5 6.5 4.2 4.9 0.5 6.5 3.8 223 5 231 305 7.5 0 7.7 7.7 09/08/2005 02:20:00 5.6 0.5 6.8 4.2 5.1 0.6 6.8 3.8 227 6 221 305 7.7 0 7.9 7.7 09/08/2005 02:30:00 5.7 0.6 6.8 3.4 5.1 0.7 6.8 3 214 6 211 305 7.5 0 7.7 7.4 09/08/2005 02:40:00 6.1 0.5 7.2 4.2 5.5 0.6 6.8 3.8 223 6 213 305 7.4 0 7.7 7.4 09/08/2005 02:50:00 5.7 0.5 6.8 4.2 5.2 0.6 6.5 3.8 224 5 223 305 7.7 0 7.9 7.7 09/08/2005 03:00:00 5.7 0.3 6.5 4.6 5.2 0.4 6.1 3.8 220 3 221 305 7.7 0 7.9 7.7 09/08/2005 03:10:00 5.2 0.4 6.1 3.8 4.6 0.5 6.1 3.4 226 5 220 305 7.7 0 7.7 7.4 09/08/2005 03:20:00 5.5 0.5 7.2 4.2 4.8 0.5 6.5 3.4 223 5 218 305 7.5 0 7.7 7.4 09/08/2005 03:30:00 4.9 0.7 6.1 3 4.5 0.7 6.1 2.6 221 7 218 305 7.6 0 7.9 7.7 09/08/2005 03:40:00 4.4 0.5 5.3 3 4.1 0.5 5.3 2.6 223 9 210 305 7.7 0 7.9 7.7 09/08/2005 03:50:00 4.1 0.6 5.3 2.3 3.8 0.5 5.3 2.6 225 9 234 305 7.7 0 7.9 7.7 09/08/2005 04:00:00 4.5 0.6 5.7 2.6 4.4 0.5 5.7 2.6 214 7 228 305 7.7 0 7.9 7.7 09/08/2005 04:10:00 4.7 0.6 6.5 3.4 4.8 0.6 6.5 3.4 205 8 215 305 7.7 0 7.9 7.7 09/08/2005 04:20:00 4.5 0.4 5.7 3.4 4.7 0.4 6.1 3.4 202 7 197 305 7.9 0 7.9 7.9 09/08/2005 04:30:00 4.6 0.5 6.1 3 4.8 0.5 6.5 3.4 194 7 194 305 7.8 0 8.2 7.7 09/08/2005 04:40:00 5.5 0.5 6.8 3.4 5.7 0.6 7.2 4.2 194 7 189 305 8 0 8.2 7.7 09/08/2005 04:50:00 5.7 0.6 6.8 4.2 5.7 0.6 7.6 4.2 196 5 201 305 7.7 0 7.9 7.7 09/08/2005 05:00:00 5.7 0.5 6.8 4.2 5.6 0.5 7.2 4.2 198 4 203 305 7.5 0 7.7 7.4 09/08/2005 05:10:00 5.4 0.4 6.1 4.2 5.5 0.4 6.5 3.8 200 5 199 305 7.5 0 7.7 7.4 09/08/2005 05:20:00 5.2 0.3 6.1 4.2 5.2 0.3 6.1 4.2 205 4 213 305 7.4 0 7.7 7.4 09/08/2005 05:30:00 5.2 0.4 6.1 4.2 5.3 0.4 6.5 4.2 205 5 203 305 7.3 0 7.4 7.2 09/08/2005 05:40:00 5.5 0.4 6.5 4.2 5.4 0.4 6.8 3.8 199 4 204 305 7 0 7.4 7.2 09/08/2005 05:50:00 4.9 0.6 6.1 3.4 5 0.6 6.5 3.4 197 5 203 305 7 0 7.2 7.2 09/08/2005 06:00:00 4.4 0.4 5.7 3.4 4.5 0.5 5.3 3.4 195 6 195 305 7.2 0 7.4 7.2 09/08/2005 06:10:00 4.5 0.6 6.5 3 4.8 0.6 6.5 3 191 6 192 305 7.2 0 7.4 7.2 09/08/2005 06:20:00 4.5 0.6 5.7 3 5 0.6 6.1 3.8 193 4 194 305 7.5 0.1 7.7 7.4 09/08/2005 06:30:00 4.2 0.7 5.7 3 4.3 0.7 6.1 3.4 197 5 200 305 7.9 0 8.2 7.7 09/08/2005 06:40:00 4.8 0.4 5.7 3.8 5 0.4 6.1 3.8 195 4 195 305 8 0 8.2 7.9 09/08/2005 06:50:00 4.5 0.5 6.1 3 4.9 0.4 6.1 4.2 192 6 191 305 8 0 8.2 7.9 09/08/2005 07:00:00 4.6 0.9 6.5 2.3 5.2 0.7 6.8 3.4 185 6 189 305 7.9 0 8.2 7.9 09/08/2005 07:10:00 5.3 0.5 6.5 3.8 5.4 0.5 6.5 3.8 195 6 203 305 7.7 0 7.9 7.4 09/08/2005 07:20:00 5 0.8 6.8 3 5.3 0.9 7.2 3.4 190 5 188 305 7.3 0 7.7 7.2 09/08/2005 07:30:00 5.1 0.6 6.8 3 5.6 0.6 6.8 3.8 186 5 186 305 7 0 7.2 6.9 09/08/2005 07:40:00 4.8 0.7 6.5 2.6 5.7 0.8 7.2 3 183 7 192 305 7 0 7.2 6.9 09/08/2005 07:50:00 6.1 0.6 7.6 3.8 6.6 0.5 8 4.9 189 7 208 305 7 0 7.2 6.9 09/08/2005 08:00:00 6.5 0.6 8 4.2 6.9 0.4 8 5.3 188 6 192 305 6.6 0.1 6.9 6.4 09/08/2005 08:10:00 4.8 0.7 6.1 2.6 5.6 0.5 7.2 3.8 183 5 192 305 6.3 0 6.4 6.1 09/08/2005 08:20:00 5.2 0.7 6.5 2.6 5.7 0.5 7.2 4.6 190 8 187 305 6.3 0 6.4 6.1 09/08/2005 08:30:00 5.4 0.3 6.1 4.9 5.6 0.4 6.5 4.6 202 3 198 305 6.1 0 6.1 5.9 09/08/2005 08:40:00 5.4 0.4 6.5 4.2 5.6 0.5 6.8 3.8 200 3 200 305 6 0 6.1 5.9 09/08/2005 08:50:00 5.5 0.4 6.5 4.2 5.7 0.4 6.5 4.6 197 3 200 305 6.1 0 6.4 5.9 09/08/2005 09:00:00 5.4 0.4 6.5 4.2 5.6 0.4 6.5 4.2 197 3 197 305 6.5 0 6.4 6.4 09/08/2005 09:10:00 5.2 0.3 6.1 4.2 5.3 0.4 6.1 4.2 196 3 201 305 6.5 0 6.7 6.4 09/08/2005 09:20:00 5 0.5 6.1 3 5.1 0.5 6.5 3 196 5 197 305 6.6 0 6.9 6.4 09/08/2005 09:30:00 4.6 0.5 6.1 3 4.6 0.5 5.7 3.4 194 8 188 305 6.8 0 7.2 6.7 09/08/2005 09:40:00 4.7 0.4 5.7 3.8 4.8 0.3 5.7 4.2 194 5 194 305 6.7 0.1 7.2 6.4 09/08/2005 09:50:00 4.7 0.4 5.7 3 4.6 0.4 5.3 3.4 190 4 192 305 6.5 0 6.7 6.4 09/08/2005 10:00:00 4.2 0.6 5.7 1.9 4.4 0.5 5.3 2.6 188 5 183 305 6.9 0.3 7.7 6.4 09/08/2005 10:10:00 3.9 0.7 5.3 2.3 4.3 0.5 5.7 3 188 7 194 305 8 0.3 8.7 7.7 09/08/2005 10:20:00 3.8 0.5 4.9 2.3 4.3 0.4 5.3 3.4 187 5 191 305 8.6 0 8.9 8.4 09/08/2005 10:30:00 3.8 0.7 5.7 1.9 4.3 0.6 5.7 2.6 189 6 194 305 8.8 0 8.9 8.7 09/08/2005 10:40:00 3.7 0.4 4.9 2.6 3.9 0.5 5.3 2.6 205 9 210 305 8.6 0.3 8.9 8.2 09/08/2005 10:50:00 3.7 0.4 4.6 2.3 3.6 0.4 4.6 2.6 208 4 204 305 8 0 8.2 7.9 09/08/2005 11:00:00 4.3 0.7 6.1 2.3 4.2 0.6 5.3 2.3 206 6 200 305 8 0 8.2 7.9 09/08/2005 11:10:00 4 0.5 5.3 2.6 4.1 0.5 5.3 3 198 6 210 305 8.1 0 8.4 7.9 09/08/2005 11:20:00 4.3 0.5 5.7 2.3 4.3 0.5 5.7 2.6 194 6 192 305 8.5 0 8.9 8.2 09/08/2005 11:30:00 4 0.5 4.9 2.3 4 0.5 5.3 2.6 193 6 196 305 8.9 0 9.2 8.7 09/08/2005 11:40:00 3.7 0.4 4.6 2.6 3.7 0.4 4.6 2.6 209 7 206 305 9.1 0 9.2 9.2 09/08/2005 11:50:00 4.1 0.4 4.9 2.6 4 0.5 4.9 2.6 205 5 214 305 9.2 0 9.2 9.2 09/08/2005 12:00:00 4.7 0.4 5.3 3.4 4.6 0.5 5.7 3.4 208 5 206 305 9.1 0 9.2 9.2 09/08/2005 12:10:00 5.7 0.4 6.5 4.2 5.6 0.5 6.5 4.2 206 3 203 305 9 0.1 9.2 8.9 09/08/2005 12:20:00 5.7 0.4 6.5 4.2 5.7 0.5 6.5 4.2 203 5 205 305 8.8 0 8.9 8.7 09/08/2005 12:30:00 4.7 0.5 5.7 3.4 4.7 0.5 6.1 3 196 4 196 305 8.8 0 8.9 8.7 09/08/2005 12:40:00 4.6 0.4 5.7 3.8 4.5 0.5 5.7 3.4 198 5 201 305 8.9 0 9.2 8.9 09/08/2005 12:50:00 4.5 0.4 5.3 3 4.5 0.5 5.3 3 197 5 196 305 9.1 0 9.2 8.9 09/08/2005 13:00:00 4.6 0.6 5.7 3.4 4.6 0.6 5.7 3 203 6 204 305 8.9 0 9.2 8.9 09/08/2005 13:10:00 4.5 0.7 5.7 2.6 4.4 0.7 6.1 2.6 199 5 206 305 8.8 0 8.9 8.9 09/08/2005 13:20:00 4.9 0.7 6.1 3.4 4.8 0.6 6.1 3 204 7 214 305 8.9 0 9.2 8.9 09/08/2005 13:30:00 4.5 0.7 6.1 2.6 4.4 0.7 5.7 2.6 198 6 208 305 8.8 0 8.9 8.7 09/08/2005 13:40:00 4.8 0.6 6.5 3 4.6 0.7 6.1 2.6 201 5 198 305 8.8 0 9.2 8.4 09/08/2005 13:50:00 5.7 0.4 6.5 4.6 5.4 0.5 6.5 3.8 204 5 203 305 8.6 0 8.7 8.4 09/08/2005 14:00:00 5.4 0.6 6.5 3.4 5.1 0.6 6.5 3 213 6 215 305 8.8 0 8.9 8.7 09/08/2005 14:10:00 5.2 0.5 6.1 3.4 4.9 0.6 6.1 3.4 215 6 224 305 8.8 0.1 9.2 8.7 09/08/2005 14:20:00 4.7 0.6 5.7 3 4.5 0.5 6.1 2.6 202 7 208 305 9.1 0 9.2 8.9 09/08/2005 14:30:00 5.2 0.4 6.1 3.8 5.1 0.5 6.1 3.4 199 5 197 305 8.8 0 9.2 8.4 09/08/2005 14:40:00 5.4 0.5 6.5 4.2 5.3 0.5 6.5 3.4 203 5 205 305 8.3 0.1 8.7 8.2 09/08/2005 14:50:00 4.7 0.6 6.1 3.4 4.6 0.5 6.1 3.4 199 6 208 305 8.4 0 8.7 8.2 09/08/2005 15:00:00 5.6 0.5 6.5 3.8 5.4 0.5 6.5 3.4 200 5 203 305 8.5 0 8.7 8.4 09/08/2005 15:10:00 4.6 0.5 5.7 3.4 4.4 0.5 5.7 2.6 199 5 203 305 8.9 0 9.2 8.7 09/08/2005 15:20:00 3.4 0.5 4.6 2.3 3.5 0.5 4.6 1.9 197 5 199 305 9 0 9.2 8.9 09/08/2005 15:30:00 3.2 0.2 3.8 2.3 3.4 0.3 4.2 2.3 200 4 197 305 9.2 0 9.5 9.2 09/08/2005 15:40:00 3 0.6 4.2 1.1 3.1 0.6 4.2 1.5 201 6 203 305 9.2 0 9.5 9.2 09/08/2005 15:50:00 3.5 0.5 4.6 2.3 3.5 0.5 4.9 2.3 194 5 194 305 8.9 0.2 9.5 8.7 09/08/2005 16:00:00 2.9 0.5 3.8 1.5 3 0.5 3.8 1.5 206 8 201 305 8.7 0 8.9 8.4 09/08/2005 16:10:00 2.4 0.3 3 1.5 2.6 0.3 3 1.5 206 12 198 305 8.6 0 8.9 8.4 09/08/2005 16:20:00 2.6 0.3 3.4 1.5 2.7 0.3 3.4 1.9 217 8 231 305 8.5 0 8.7 8.4 09/08/2005 16:30:00 3.1 0.6 4.2 1.9 3.2 0.5 4.2 2.3 209 6 203 305 8.8 0.1 8.9 8.4 09/08/2005 16:40:00 2.9 0.4 3.8 1.9 3.1 0.4 3.8 1.9 206 5 197 305 8.7 0 8.9 8.7 09/08/2005 16:50:00 2.6 0.4 3.8 1.5 2.8 0.5 3.8 1.5 209 8 213 305 8.8 0 8.9 8.7 09/08/2005 17:00:00 3.1 0.5 4.2 1.1 3.5 0.4 4.6 2.3 189 8 193 305 8.8 0 8.9 8.7 09/08/2005 17:10:00 2.7 1 4.6 0.7 3.4 0.7 4.9 1.9 171 17 190 305 8.6 0 8.9 8.4 09/08/2005 17:20:00 2.9 0.8 4.6 1.1 3.1 0.7 4.6 1.5 146 7 147 305 8.3 0.1 8.4 8.2 09/08/2005 17:30:00 1.1 0.6 2.6 0.4 1.9 0.5 2.6 0.7 168 23 135 305 8.5 0 8.7 8.2 09/08/2005 17:40:00 1.7 0.5 3 0.4 2.1 0.4 3.4 1.1 207 18 197 305 8.4 0 8.4 8.2 09/08/2005 17:50:00 2.9 0.4 3.8 1.9 3.1 0.4 4.2 1.9 195 7 192 305 8.3 0 8.4 8.2 09/08/2005 18:00:00 2.2 0.4 2.6 1.1 2.4 0.3 3 1.5 213 6 208 305 8.1 0 8.2 7.9 09/08/2005 18:10:00 0.9 0.4 1.9 0.4 1.7 0.2 2.3 1.1 195 13 203 305 8.1 0 8.2 7.9 09/08/2005 18:20:00 0.4 0.2 1.1 0.4 0.8 0.5 1.9 0.4 201 13 179 305 8.2 0 8.2 8.2 09/08/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 210 13 305 305 8.3 0 8.4 8.2 09/08/2005 18:40:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 111 20 305 305 8.5 0 8.7 8.2 09/08/2005 18:50:00 0.5 0.2 1.1 0.4 1.1 0.4 2.3 0.4 39 3 48 305 8.4 0.1 8.7 8.2 09/08/2005 19:00:00 2.1 0.5 3 0.4 2.8 0.4 3.8 1.1 45 4 46 305 8 0 8.4 7.9 09/08/2005 19:10:00 2.8 0.2 3.4 2.3 3.3 0.3 3.8 2.6 47 3 47 305 7.7 0 7.9 7.7 09/08/2005 19:20:00 1.9 0.4 2.6 0.7 2.4 0.4 3.4 1.5 62 12 65 305 7.9 0 8.2 7.7 09/08/2005 19:30:00 3 0.4 4.2 1.9 3.4 0.3 4.2 2.6 59 9 74 305 7.8 0 8.2 7.7 09/08/2005 19:40:00 3.2 0.5 4.2 1.9 3.3 0.4 4.6 2.3 85 7 75 305 7.9 0 8.2 7.7 09/08/2005 19:50:00 3.7 0.3 4.6 3 3.8 0.3 4.6 3 78 4 76 305 8.1 0 8.4 7.9 09/08/2005 20:00:00 3.7 0.2 4.2 3 3.8 0.2 4.2 3 80 4 85 305 8 0 8.2 7.9 09/08/2005 20:10:00 3.7 0.2 4.2 3 3.7 0.2 4.2 3.4 73 3 80 305 7.9 0 7.9 7.9 09/08/2005 20:20:00 3.9 0.3 4.9 3 4 0.3 4.6 3.4 74 5 82 305 7.7 0 7.9 7.7 09/08/2005 20:30:00 4.1 0.5 5.3 2.6 4.1 0.5 5.3 3 83 5 86 305 7.7 0 8.2 7.7 09/08/2005 20:40:00 4.6 0.5 5.7 3 4.4 0.5 5.7 3 86 7 82 305 7.8 0 8.2 7.7 09/08/2005 20:50:00 4.5 0.5 5.3 3 4.5 0.5 5.7 3 92 5 84 305 7.8 0 8.2 7.7 09/08/2005 21:00:00 3.9 0.4 4.9 3 4 0.4 4.9 3 94 6 96 305 7.9 0 8.4 7.7 09/08/2005 21:10:00 4.2 0.5 5.3 2.6 4.1 0.4 5.3 3 91 5 95 305 7.7 0.1 8.2 7.7 09/08/2005 21:20:00 4.5 0.5 5.7 3.4 4.5 0.5 5.7 3.4 88 5 88 305 7.7 0.1 8.2 7.7 09/08/2005 21:30:00 4.8 0.5 5.7 3.4 4.7 0.5 5.7 3.4 86 5 87 305 7.6 0 7.7 7.7 09/08/2005 21:40:00 5.4 0.7 7.2 3.8 5.3 0.6 7.2 4.2 79 5 76 305 7.6 0 7.7 7.7 09/08/2005 21:50:00 5.9 0.5 7.2 4.6 5.7 0.5 6.8 4.6 74 5 77 305 7.8 0 7.9 7.7 09/08/2005 22:00:00 5.6 0.5 6.8 4.2 5.4 0.5 6.8 4.2 70 4 70 305 7.6 0 7.9 7.4 09/08/2005 22:10:00 6 0.4 6.8 5.3 5.8 0.3 6.8 4.9 69 3 67 305 7.3 0 7.7 7.2 09/08/2005 22:20:00 6.6 0.4 8 5.3 6.3 0.4 7.6 5.3 73 4 73 305 7.3 0 7.4 7.2 09/08/2005 22:30:00 6.8 0.6 8.4 5.3 6.6 0.6 8.4 4.6 82 8 86 305 7.5 0 7.7 7.4 09/08/2005 22:40:00 6.6 0.7 8 4.6 6.4 0.6 8 4.6 81 6 81 305 7.5 0 7.7 7.4 09/08/2005 22:50:00 6.4 0.7 8.8 4.9 6.3 0.7 8.4 4.9 81 6 80 305 7.5 0 7.7 7.4 09/08/2005 23:00:00 6.7 0.6 8 4.9 6.5 0.6 8 4.2 81 7 77 305 7.5 0 7.7 7.4 09/08/2005 23:10:00 6.6 0.6 8 4.6 6.4 0.6 7.6 4.9 77 6 87 305 7.5 0 7.7 7.4 09/08/2005 23:20:00 6.5 0.5 9.9 4.9 6.4 0.5 8.8 4.9 73 5 77 305 7.5 0 7.7 7.4 09/08/2005 23:30:00 6.6 0.6 8 4.6 6.3 0.6 7.6 4.6 76 6 60 305 7.4 0 7.7 7.4 09/08/2005 23:40:00 6.7 0.6 8.4 4.9 6.4 0.5 8 4.6 78 6 72 305 7.5 0 7.9 7.4 09/08/2005 23:50:00 6.2 0.6 8.4 4.9 6 0.6 7.6 4.2 71 6 73 305 7.5 0 7.9 7.4 09/09/2005 00:00:00 6 0.6 7.6 4.2 5.7 0.6 7.2 3.8 67 6 71 305 7.3 0.1 7.9 7.2 09/09/2005 00:10:00 5.3 0.5 6.5 3.8 5.1 0.6 6.8 3.8 63 6 69 305 7.2 0.1 7.7 7.2 09/09/2005 00:20:00 5.1 0.5 6.1 3.4 4.9 0.5 6.1 3.8 59 3 55 305 7 0 7.4 6.9 09/09/2005 00:30:00 5.4 0.6 7.2 3.8 5.3 0.5 7.2 4.2 62 6 59 305 7 0 7.4 6.9 09/09/2005 00:40:00 5.1 0.4 6.5 4.2 5 0.4 6.1 3.8 62 4 75 305 6.9 0 7.4 6.9 09/09/2005 00:50:00 5.5 0.3 6.1 4.6 5.4 0.3 6.1 4.9 57 3 59 305 6.8 0.1 7.4 6.7 09/09/2005 01:00:00 4.8 0.4 5.7 3.8 4.8 0.4 5.7 3.8 56 4 52 305 6.7 0.1 7.4 6.4 09/09/2005 01:10:00 4.8 0.4 6.1 3.8 4.6 0.3 5.7 3.8 58 4 63 305 6.7 0.1 7.4 6.4 09/09/2005 01:20:00 5.6 0.5 6.8 4.6 5.4 0.5 6.8 4.6 48 3 44 305 6.5 0 7.2 6.4 09/09/2005 01:30:00 7.3 0.5 8 6.1 7.1 0.6 8.4 5.3 42 3 40 305 6.7 0.2 7.4 6.4 09/09/2005 01:40:00 7.6 0.3 8.4 6.8 7.5 0.3 8.4 6.8 40 2 41 305 6.7 0 7.4 6.7 09/09/2005 01:50:00 7.8 0.3 8.4 7.2 7.7 0.3 8.4 6.8 41 3 39 305 6.8 0.1 7.4 6.7 09/09/2005 02:00:00 8.2 0.3 8.8 7.2 7.9 0.3 8.8 6.8 41 3 40 305 6.7 0.1 7.4 6.7 09/09/2005 02:10:00 8.6 0.4 9.5 7.2 8.3 0.4 9.5 7.2 42 3 40 305 6.7 0 6.9 6.7 09/09/2005 02:20:00 8.5 0.4 9.5 7.6 8.3 0.4 9.5 7.2 40 3 41 305 6.7 0 6.9 6.7 09/09/2005 02:30:00 8.4 0.3 9.1 7.2 8.2 0.3 9.1 7.2 39 3 38 305 6.7 0 6.9 6.7 09/09/2005 02:40:00 8.8 0.3 9.5 7.6 8.6 0.4 9.5 7.2 36 3 42 305 6.8 0 6.9 6.7 09/09/2005 02:50:00 9 0.4 10.3 8 8.8 0.4 9.9 7.6 35 3 36 305 6.9 0 7.2 6.9 09/09/2005 03:00:00 9.3 0.5 10.7 8 9.1 0.5 10.3 8 33 3 36 305 7 0 7.2 6.9 09/09/2005 03:10:00 9.6 0.4 10.7 8.4 9.4 0.5 10.7 7.6 31 3 31 305 7 0 7.7 6.9 09/09/2005 03:20:00 9.8 0.5 11.5 8.4 9.6 0.5 11.5 8 32 3 34 305 7 0 7.2 7.2 09/09/2005 03:30:00 10.3 0.5 11.5 9.1 10.1 0.5 11.5 8.8 33 3 35 305 7 0 7.7 7.2 09/09/2005 03:40:00 10.5 0.5 12.2 9.1 10.3 0.5 12.2 8.8 36 3 36 305 7 0 7.2 7.2 09/09/2005 03:50:00 10.9 0.5 12.2 9.5 10.8 0.5 12.2 9.1 37 3 39 305 7.1 0.1 7.7 7.2 09/09/2005 04:00:00 10.8 0.4 11.8 9.5 10.5 0.5 11.8 8.8 37 3 39 305 7.2 0 7.4 7.2 09/09/2005 04:10:00 10.8 0.5 12.2 9.5 10.6 0.5 12.2 9.1 36 3 35 305 7.3 0 7.7 7.2 09/09/2005 04:20:00 11.2 0.6 12.6 9.5 11 0.6 12.6 9.5 34 3 31 305 7.3 0.1 7.9 7.2 09/09/2005 04:30:00 10.9 0.6 12.2 9.1 10.7 0.6 12.6 9.1 32 3 38 305 7.3 0 7.9 7.4 09/09/2005 04:40:00 10.4 0.5 11.8 9.1 10.3 0.5 11.5 8.8 31 3 28 305 7.4 0 7.9 7.4 09/09/2005 04:50:00 10.7 0.5 12.2 9.5 10.5 0.5 12.2 9.5 32 3 31 305 7.5 0 7.9 7.4 09/09/2005 05:00:00 10.6 0.6 12.2 9.1 10.4 0.6 12.2 8.8 30 3 30 305 7.3 0.1 7.9 7.2 09/09/2005 05:10:00 10.9 0.7 12.6 9.5 10.7 0.7 12.6 9.1 29 3 27 305 7.4 0 7.9 7.4 09/09/2005 05:20:00 10.9 0.6 12.6 9.1 10.7 0.8 13 8.8 27 3 29 305 7.3 0 7.7 7.4 09/09/2005 05:30:00 10.8 0.6 12.6 9.5 10.8 0.6 12.2 9.1 26 3 35 305 7.3 0 7.9 7.2 09/09/2005 05:40:00 10.8 0.6 12.6 9.1 10.7 0.7 12.6 9.1 26 3 29 305 7.3 0 7.7 7.2 09/09/2005 05:50:00 11.1 0.7 12.6 9.1 11 0.7 12.6 9.1 26 3 27 305 7.3 0 7.7 7.2 09/09/2005 06:00:00 11.4 0.6 13.3 9.9 11.3 0.7 13.7 9.5 26 4 25 305 7.3 0.1 7.9 7.2 09/09/2005 06:10:00 11.6 0.7 13 9.9 11.6 0.7 13.3 9.9 24 3 27 305 7.3 0 7.9 7.2 09/09/2005 06:20:00 11.2 0.7 12.6 9.5 11.1 0.8 12.6 8.8 22 3 22 305 7.3 0.1 7.9 7.2 09/09/2005 06:30:00 11.1 0.6 13 9.5 11 0.6 12.6 9.5 21 3 22 305 7.3 0 7.9 7.4 09/09/2005 06:40:00 11.3 0.6 12.6 9.5 11.2 0.7 12.6 9.5 22 3 21 305 7.3 0 7.4 7.4 09/09/2005 06:50:00 11.1 0.7 13 9.5 11.1 0.7 13.3 9.1 26 3 27 305 7.3 0 7.9 7.4 09/09/2005 07:00:00 11 0.6 12.2 9.5 10.9 0.7 12.6 9.1 26 3 39 305 7.3 0 7.4 7.2 09/09/2005 07:10:00 11.4 0.7 13.3 9.9 11.3 0.7 13 9.5 24 3 24 305 7.2 0 7.4 7.2 09/09/2005 07:20:00 11.7 0.7 13.3 9.9 11.6 0.7 13.7 9.5 22 3 31 305 7.2 0 7.4 7.2 09/09/2005 07:30:00 12 0.7 13.7 9.9 12 0.8 13.7 9.5 23 3 19 305 7.2 0 7.4 7.2 09/09/2005 07:40:00 11.7 0.8 13.7 9.9 11.6 0.8 13.7 9.5 24 3 27 305 7.2 0 7.4 7.2 09/09/2005 07:50:00 11.9 0.7 13.3 9.5 11.8 0.8 13.7 9.1 24 3 27 305 7.2 0 7.7 7.2 09/09/2005 08:00:00 12.2 0.7 13.7 9.9 12.2 0.8 14.1 10.3 24 3 23 305 7.2 0 7.4 7.2 09/09/2005 08:10:00 12.4 0.7 14.1 10.7 12.3 0.7 14.1 10.3 23 3 26 305 7.2 0 7.2 7.2 09/09/2005 08:20:00 12.3 0.9 14.5 9.9 12.3 0.9 14.9 9.9 26 4 34 305 7.2 0 7.4 7.2 09/09/2005 08:30:00 12.3 0.7 14.5 10.3 12.1 0.8 14.1 9.9 25 3 28 305 7.2 0 7.4 7.2 09/09/2005 08:40:00 12.2 0.7 14.1 10.3 12.1 0.8 13.7 10.3 21 4 23 305 7.1 0 7.4 6.9 09/09/2005 08:50:00 12 0.9 14.5 9.9 11.9 0.9 14.5 9.1 20 4 26 305 6.8 0.1 7.4 6.7 09/09/2005 09:00:00 12.1 0.7 14.1 10.3 12 0.9 14.1 9.9 19 3 21 305 6.8 0 7.4 6.7 09/09/2005 09:10:00 12.1 0.7 14.1 10.3 12.1 0.7 14.1 9.5 17 3 19 305 6.8 0 7.4 6.7 09/09/2005 09:20:00 11.6 0.8 13.7 9.9 11.5 0.9 13.7 9.1 18 3 13 305 6.8 0 7.4 6.9 09/09/2005 09:30:00 12 0.9 14.1 9.9 11.9 0.9 14.1 9.1 19 3 17 305 6.9 0 7.4 6.9 09/09/2005 09:40:00 12.1 0.8 14.1 10.3 12.2 0.8 14.1 10.3 16 3 12 305 6.8 0.1 7.4 6.7 09/09/2005 09:50:00 12.6 1 14.9 10.3 12.6 1.1 15.6 9.9 17 3 16 305 6.7 0 7.2 6.7 09/09/2005 10:00:00 13.4 1 15.3 10.7 13.3 1.1 15.6 10.7 20 3 17 305 6.7 0 7.4 6.7 09/09/2005 10:10:00 12.9 1 15.3 9.9 12.8 1 15.6 10.3 21 3 13 305 6.8 0 7.4 6.7 09/09/2005 10:20:00 12.7 0.9 15.3 10.3 12.6 1 15.3 10.3 20 3 20 305 6.9 0 7.4 6.9 09/09/2005 10:30:00 12.4 0.9 14.9 10.7 12.3 1 14.9 9.9 22 3 24 305 7 0 7.4 6.9 09/09/2005 10:40:00 12.4 0.7 14.1 10.3 12.4 0.8 14.1 10.3 23 4 23 305 7 0 7.4 6.9 09/09/2005 10:50:00 12.4 0.8 14.9 10.3 12.3 0.9 14.5 9.9 25 4 31 305 6.9 0 7.4 6.9 09/09/2005 11:00:00 12.1 0.8 14.5 9.9 12 0.9 14.1 9.5 23 4 27 305 6.8 0.1 7.4 6.7 09/09/2005 11:10:00 12.5 1 14.1 9.1 12.4 1.1 14.5 9.5 18 4 27 305 6.6 0 7.2 6.4 09/09/2005 11:20:00 11.7 1.1 14.1 8.4 11.7 1.2 14.1 8.8 15 4 14 305 6.6 0 7.2 6.4 09/09/2005 11:30:00 11.5 0.9 13.7 9.5 11.5 1 14.1 9.5 9 4 11 305 6.5 0 7.2 6.4 09/09/2005 11:40:00 12.2 1 14.5 9.5 12.3 1.1 14.5 9.5 8 4 4 305 6.5 0 6.4 6.4 09/09/2005 11:50:00 12.5 0.9 14.5 9.9 12.5 1 14.5 9.5 8 4 10 305 6.5 0 7.2 6.4 09/09/2005 12:00:00 12.7 0.8 14.9 10.3 12.7 0.8 14.9 10.3 6 4 8 305 6.5 0 6.7 6.4 09/09/2005 12:10:00 12.7 1.1 14.9 9.9 12.7 1.1 14.9 9.5 5 4 5 305 6.5 0 6.7 6.4 09/09/2005 12:20:00 13 1 15.3 10.3 13 1 15.6 10.3 7 4 6 305 6.5 0 6.7 6.4 09/09/2005 12:30:00 13.6 1.2 16.8 9.9 13.6 1.2 16.8 9.9 12 4 7 305 6.6 0 6.7 6.4 09/09/2005 12:40:00 12.7 1.1 16.1 9.9 12.8 1.1 15.6 9.5 12 3 8 305 6.6 0 6.7 6.4 09/09/2005 12:50:00 12.9 1 15.3 9.5 12.9 1.1 15.3 9.5 9 5 5 305 6.7 0 6.9 6.4 09/09/2005 13:00:00 12.4 0.9 14.5 10.3 12.4 1 14.9 10.3 7 5 8 305 6.7 0 6.9 6.7 09/09/2005 13:10:00 13.3 1 15.6 10.7 13.3 1 16.1 10.3 7 4 5 305 6.7 0 6.9 6.7 09/09/2005 13:20:00 13.2 1.1 15.3 9.9 13.2 1.1 16.1 9.5 8 4 15 305 6.8 0 7.4 6.9 09/09/2005 13:30:00 13.4 0.9 15.3 10.7 13.4 1 15.6 9.9 9 3 13 305 6.8 0 7.4 6.7 09/09/2005 13:40:00 13.5 1.3 16.4 9.9 13.6 1.2 16.8 9.5 6 4 8 305 7 0 7.4 6.9 09/09/2005 13:50:00 13.2 1.2 16.1 10.7 13.3 1.2 16.4 10.3 3 4 8 305 6.9 0 7.4 6.9 09/09/2005 14:00:00 12.8 1.1 15.6 10.3 12.9 1.1 15.3 9.9 3 3 5 305 7 0 7.7 6.9 09/09/2005 14:10:00 12.6 1 14.9 9.1 12.7 1.1 15.3 8.8 2 4 354 305 7.1 0 7.7 7.2 09/09/2005 14:20:00 12.2 1 14.5 9.1 12.2 1.1 14.5 9.1 3 4 2 305 7.1 0.1 7.7 7.2 09/09/2005 14:30:00 12.4 1.3 15.3 9.1 12.5 1.3 15.3 8.8 2 3 4 305 7.1 0 7.7 7.2 09/09/2005 14:40:00 13 1 15.3 10.3 13.1 1 15.3 10.3 2 3 7 305 7 0 7.7 7.2 09/09/2005 14:50:00 12.6 1 15.3 9.5 12.7 1.1 15.6 9.9 4 4 2 305 7 0 7.7 6.9 09/09/2005 15:00:00 11.3 0.8 13.3 9.1 11.3 0.9 13.3 8.8 359 5 1 305 7.1 0.1 7.7 6.9 09/09/2005 15:10:00 11.4 0.9 13 8.4 11.6 1 13.3 8 0 4 1 305 7 0 7.7 6.9 09/09/2005 15:20:00 11 0.8 13.3 8.8 11.1 0.9 13.3 8.8 2 4 358 305 7.1 0 7.7 7.2 09/09/2005 15:30:00 10.6 0.8 12.6 8.4 10.7 0.9 13 8.8 3 3 0 305 7.3 0.1 7.7 7.2 09/09/2005 15:40:00 10.5 0.8 12.2 8 10.5 0.9 12.2 8 2 3 8 305 7.5 0 7.9 7.4 09/09/2005 15:50:00 10.9 0.8 13 8.8 11 0.8 13 8.8 0 3 359 305 7.6 0 7.9 7.7 09/09/2005 16:00:00 9.9 1 12.2 7.6 10 1 12.6 8 0 4 4 305 7.7 0 7.9 7.7 09/09/2005 16:10:00 10.5 1 12.2 8.4 10.7 1 12.6 8 2 3 1 305 7.5 0 7.7 7.4 09/09/2005 16:20:00 10.4 0.8 12.2 8.4 10.5 0.9 13 7.6 1 3 359 305 7.3 0 7.4 7.2 09/09/2005 16:30:00 10 0.7 11.8 8.4 10 0.7 12.2 8.4 3 4 6 305 7.2 0 7.4 7.2 09/09/2005 16:40:00 10 0.6 11.8 7.6 10.1 0.7 11.5 7.2 2 3 1 305 7.2 0 7.4 7.2 09/09/2005 16:50:00 9.8 0.7 11.5 8 9.9 0.7 11.5 7.6 2 3 358 305 7.3 0 7.7 7.2 09/09/2005 17:00:00 9.6 0.7 11.1 7.6 9.7 0.7 11.5 7.2 2 3 359 305 7.2 0 7.4 7.2 09/09/2005 17:10:00 10 0.8 11.5 7.6 10.2 0.8 11.8 8 2 3 0 305 7.2 0 7.4 7.2 09/09/2005 17:20:00 9 0.8 11.1 6.8 9.2 0.8 11.1 7.2 0 3 358 305 7.2 0 7.4 7.2 09/09/2005 17:30:00 8.9 0.6 10.3 7.2 9 0.6 10.3 6.8 0 3 358 305 7.2 0 7.4 7.2 09/09/2005 17:40:00 8.2 0.6 9.5 6.5 8.2 0.7 9.9 6.5 3 3 3 305 7.2 0 7.4 7.2 09/09/2005 17:50:00 8.3 0.6 9.5 6.8 8.5 0.7 9.9 6.5 2 3 2 305 7.3 0 7.9 7.4 09/09/2005 18:00:00 8.9 0.5 10.3 7.6 9.1 0.6 11.1 6.8 3 3 4 305 7.3 0.1 7.9 7.2 09/09/2005 18:10:00 8.8 0.6 10.7 6.8 9 0.6 11.1 7.6 5 3 10 305 7.3 0.1 7.9 7.2 09/09/2005 18:20:00 9.4 1 12.2 7.2 9.4 1 12.2 6.8 8 4 13 305 7.5 0.1 8.2 7.4 09/09/2005 18:30:00 10.7 0.7 12.6 9.1 10.6 0.7 12.2 9.1 11 4 5 305 7.6 0 8.2 7.4 09/09/2005 18:40:00 10.1 0.6 12.2 8.8 10.2 0.6 12.2 8.8 8 4 1 305 7.5 0 8.2 7.4 09/09/2005 18:50:00 10.1 0.8 12.6 8.4 10.2 0.8 13 8 9 4 12 305 7.5 0 7.9 7.4 09/09/2005 19:00:00 9.2 0.6 10.7 7.2 9.3 0.6 10.7 7.6 9 3 8 305 7.5 0 7.9 7.4 09/09/2005 19:10:00 9.4 0.8 11.1 7.6 9.5 0.8 11.5 7.6 4 4 5 305 7.5 0 7.9 7.4 09/09/2005 19:20:00 8.4 0.7 10.3 6.8 8.6 0.7 10.7 6.8 359 3 358 305 7.5 0 7.9 7.4 09/09/2005 19:30:00 8.1 0.6 9.9 6.8 8.3 0.7 10.3 6.5 357 4 1 305 7.5 0 7.9 7.4 09/09/2005 19:40:00 8.3 0.5 9.5 6.8 8.5 0.6 9.9 6.8 358 4 354 305 7.5 0 8.2 7.4 09/09/2005 19:50:00 8 0.6 9.5 5.7 8.2 0.6 9.9 6.5 357 3 3 305 7.3 0 7.9 7.2 09/09/2005 20:00:00 7.5 0.5 8.8 5.7 7.7 0.5 9.1 6.5 358 3 358 305 7.3 0 7.9 7.2 09/09/2005 20:10:00 7.3 0.5 8.8 6.1 7.5 0.5 9.1 6.1 354 3 351 305 7.2 0.1 7.7 7.2 09/09/2005 20:20:00 6.8 0.5 8 5.7 7.1 0.5 8.4 5.7 355 3 353 305 7 0 7.2 6.9 09/09/2005 20:30:00 6.5 0.4 7.6 5.3 6.7 0.5 8 5.7 354 3 358 305 7 0 7.2 6.9 09/09/2005 20:40:00 6.4 0.4 7.2 5.3 6.7 0.4 7.6 5.7 352 3 347 305 7 0 7.2 6.9 09/09/2005 20:50:00 6.5 0.4 7.6 5.3 6.7 0.4 7.6 5.7 355 3 351 305 6.8 0 7.2 6.9 09/09/2005 21:00:00 6 0.4 7.2 5.3 6.3 0.4 7.6 5.3 354 3 5 305 6.7 0 6.9 6.7 09/09/2005 21:10:00 5.8 0.3 6.8 4.9 6.1 0.4 7.2 4.6 355 3 359 305 6.7 0 7.2 6.7 09/09/2005 21:20:00 6.1 0.4 7.2 4.9 6.4 0.4 7.6 5.3 351 3 354 305 6.6 0 6.9 6.4 09/09/2005 21:30:00 6.3 0.5 7.6 5.3 6.5 0.5 8.4 5.3 355 4 348 305 6.7 0 6.9 6.7 09/09/2005 21:40:00 5.9 0.5 7.2 4.9 6.1 0.4 7.2 5.3 2 4 358 305 6.6 0 6.9 6.4 09/09/2005 21:50:00 5.3 0.4 6.5 4.6 5.6 0.4 6.8 4.9 0 5 357 305 6.6 0 6.9 6.4 09/09/2005 22:00:00 5.1 0.5 6.1 4.2 5.4 0.5 6.8 4.2 357 3 359 305 6.6 0 6.9 6.4 09/09/2005 22:10:00 4.8 0.3 5.7 4.2 5.1 0.3 5.7 3.8 349 3 353 305 6.6 0 6.9 6.4 09/09/2005 22:20:00 4.9 0.3 5.7 4.2 5.2 0.3 6.1 4.6 353 4 348 305 6.7 0 6.9 6.7 09/09/2005 22:30:00 4.7 0.3 5.3 4.2 4.9 0.3 5.7 4.2 356 3 355 305 6.8 0 6.9 6.7 09/09/2005 22:40:00 4.5 0.3 5.3 3.8 4.6 0.3 5.3 3.8 353 3 352 305 6.7 0 6.9 6.7 09/09/2005 22:50:00 4.5 0.4 5.3 3.8 4.6 0.4 5.3 3.8 356 4 353 305 6.7 0 6.9 6.7 09/09/2005 23:00:00 4.3 0.2 4.9 3.8 4.3 0.2 4.9 3.8 350 2 348 305 6.8 0 6.9 6.7 09/09/2005 23:10:00 4.7 0.2 5.3 4.2 4.6 0.2 5.3 4.2 346 4 342 305 6.8 0 7.2 6.9 09/09/2005 23:20:00 3.5 0.5 4.9 2.6 3.5 0.4 4.6 2.6 332 5 339 305 6.8 0 7.2 6.9 09/09/2005 23:30:00 3.6 0.3 4.6 3 3.5 0.3 4.2 3 328 4 331 305 6.8 0 7.2 6.9 09/09/2005 23:40:00 3.6 0.3 4.2 3 3.6 0.3 4.2 3 345 5 335 305 6.9 0 7.4 6.9 09/09/2005 23:50:00 3.1 0.3 4.2 2.3 3.2 0.3 3.8 2.6 343 6 351 305 6.9 0 7.2 6.9 09/10/2005 00:00:00 3.5 0.3 4.6 3 3.5 0.2 4.2 3 342 5 348 305 6.8 0 7.2 6.9 09/10/2005 00:10:00 3.9 0.5 4.9 2.6 3.8 0.5 4.9 2.6 349 6 348 305 6.8 0 6.9 6.7 09/10/2005 00:20:00 4.4 0.3 4.9 3.8 4.5 0.3 5.3 3.8 353 5 352 305 6.8 0 6.9 6.7 09/10/2005 00:30:00 4.7 0.4 5.3 3.8 4.8 0.3 5.7 4.2 348 2 350 305 6.7 0 6.9 6.7 09/10/2005 00:40:00 5.5 0.5 6.8 4.6 5.4 0.5 7.2 4.6 346 3 350 305 6.7 0 7.2 6.7 09/10/2005 00:50:00 6.1 0.4 7.2 4.9 6.1 0.4 7.2 4.9 342 4 343 305 6.8 0 6.9 6.7 09/10/2005 01:00:00 6.5 0.5 7.6 5.3 6.6 0.5 8 5.3 344 4 342 305 6.9 0 7.2 6.9 09/10/2005 01:10:00 5.9 0.8 7.2 4.2 6 0.8 8 4.2 347 4 348 305 7 0 7.2 6.9 09/10/2005 01:20:00 6.4 1 8.4 4.2 6.4 1 8.4 4.6 358 7 359 305 7 0 7.2 6.9 09/10/2005 01:30:00 6.4 0.8 8.4 4.6 6.4 0.8 8 4.6 7 3 7 305 7 0 7.2 6.9 09/10/2005 01:40:00 5.5 0.5 6.8 4.6 5.5 0.5 6.8 4.6 6 4 2 305 7 0 7.2 6.9 09/10/2005 01:50:00 5.5 0.3 6.5 4.6 5.6 0.3 6.5 4.6 1 4 8 305 7 0 7.2 6.9 09/10/2005 02:00:00 5.4 0.5 6.8 4.2 5.5 0.5 6.8 4.2 354 4 355 305 7 0 7.2 6.9 09/10/2005 02:10:00 6.6 0.4 7.6 5.7 6.6 0.4 7.6 5.3 359 3 2 305 7 0 7.2 6.9 09/10/2005 02:20:00 6.7 0.5 8 5.7 6.8 0.4 8 5.7 5 4 2 305 7 0 7.2 6.9 09/10/2005 02:30:00 6.6 0.5 8 5.3 6.6 0.5 8 5.3 6 4 14 305 7 0 7.2 6.9 09/10/2005 02:40:00 6.6 0.5 7.6 5.3 6.6 0.5 8 5.3 10 4 5 305 7 0 7.2 6.9 09/10/2005 02:50:00 6.3 0.4 7.2 5.3 6.3 0.4 7.2 5.3 14 3 14 305 7 0 7.2 6.9 09/10/2005 03:00:00 6.4 0.4 7.6 5.3 6.4 0.4 7.6 5.3 16 4 15 305 7 0 7.2 6.9 09/10/2005 03:10:00 6.2 0.4 7.2 4.9 6.2 0.5 7.6 5.3 19 4 16 305 7 0 7.2 6.9 09/10/2005 03:20:00 5.9 0.5 7.2 4.6 5.9 0.5 7.6 4.6 18 4 16 305 6.8 0 7.2 6.9 09/10/2005 03:30:00 6.5 0.4 7.6 5.3 6.5 0.4 7.6 5.7 16 3 15 305 7 0 7.2 6.9 09/10/2005 03:40:00 6.1 0.5 7.2 5.3 6.2 0.5 7.6 4.9 15 4 13 305 6.8 0 7.2 6.9 09/10/2005 03:50:00 6.1 0.5 7.6 5.3 6.2 0.5 7.2 4.9 12 3 9 305 6.8 0 6.9 6.9 09/10/2005 04:00:00 6.4 0.4 7.6 5.3 6.5 0.4 7.2 5.7 14 3 13 305 6.8 0 6.9 6.7 09/10/2005 04:10:00 6.4 0.4 8 5.7 6.5 0.4 7.2 5.7 16 3 16 305 6.7 0 6.9 6.7 09/10/2005 04:20:00 5.7 0.5 7.2 4.6 6 0.4 7.2 4.9 17 2 15 305 6.7 0 6.9 6.4 09/10/2005 04:30:00 5.4 0.4 6.5 4.6 5.4 0.4 6.5 4.6 17 3 17 305 6.6 0 6.9 6.4 09/10/2005 04:40:00 5 0.4 6.1 4.2 5.2 0.4 6.1 4.2 17 3 16 305 6.6 0 6.9 6.4 09/10/2005 04:50:00 4.7 0.4 5.7 3.8 4.7 0.5 5.7 3.4 20 4 17 305 6.5 0 6.9 6.4 09/10/2005 05:00:00 4.7 0.4 5.7 3.4 4.5 0.4 5.7 3.4 24 5 19 305 6.5 0 6.7 6.1 09/10/2005 05:10:00 4.4 0.3 5.3 3.4 4.3 0.4 5.3 3.4 27 4 23 305 6.4 0 6.4 6.1 09/10/2005 05:20:00 3.9 0.4 5.3 3 3.9 0.4 4.9 3 29 5 24 305 6.5 0 6.4 6.1 09/10/2005 05:30:00 3.9 0.4 4.6 3 4 0.4 4.9 2.6 31 7 29 305 6.5 0 6.4 6.1 09/10/2005 05:40:00 4.1 0.4 5.3 3 4 0.3 4.9 3.4 27 5 28 305 6.5 0 6.7 6.1 09/10/2005 05:50:00 4.4 0.4 5.3 3.4 4.4 0.4 5.7 3.4 27 5 35 305 6.5 0 6.4 6.1 09/10/2005 06:00:00 3.7 0.3 4.6 2.6 3.7 0.3 4.6 3 31 6 30 305 6.4 0 6.4 6.1 09/10/2005 06:10:00 3.6 0.3 4.6 3 3.6 0.3 4.6 3 34 6 29 305 6.4 0 6.4 6.1 09/10/2005 06:20:00 3.3 0.4 4.6 2.6 3.5 0.3 4.6 2.6 38 7 20 305 6.5 0 6.4 6.1 09/10/2005 06:30:00 2.6 0.4 3.8 1.1 2.7 0.4 3.8 1.9 51 9 36 305 6.5 0 6.4 6.1 09/10/2005 06:40:00 2 0.6 3.4 0.4 2.4 0.4 3.4 1.1 55 11 62 305 6.5 0 6.7 6.1 09/10/2005 06:50:00 1.5 0.5 3 0.4 1.9 0.3 2.6 1.1 49 9 40 305 6.6 0 6.9 6.4 09/10/2005 07:00:00 1.6 0.4 2.3 0.4 2.1 0.3 2.6 1.5 46 8 37 305 6.8 0 6.9 6.7 09/10/2005 07:10:00 2.3 0.6 3.4 1.1 2.7 0.4 3.8 1.5 42 10 42 305 6.8 0 7.2 6.7 09/10/2005 07:20:00 2.6 0.5 3.8 1.5 2.9 0.4 4.2 1.9 34 11 31 305 6.8 0 7.2 6.7 09/10/2005 07:30:00 2.6 0.4 3.8 1.5 3.1 0.4 4.2 2.3 26 6 26 305 6.9 0 7.2 6.7 09/10/2005 07:40:00 2.8 0.5 4.2 1.5 3.2 0.5 4.2 2.3 22 6 28 305 6.8 0 6.9 6.7 09/10/2005 07:50:00 1.8 0.4 2.6 0.7 2.3 0.3 3 1.5 23 7 24 305 6.7 0 6.9 6.4 09/10/2005 08:00:00 1.7 0.4 3 0.7 2.2 0.3 3 1.5 18 6 20 305 6.8 0 7.2 6.7 09/10/2005 08:10:00 2.1 0.4 3 1.5 2.5 0.3 3.4 1.9 25 5 41 305 6.8 0.1 7.2 6.4 09/10/2005 08:20:00 2.5 0.5 3.4 1.5 2.9 0.4 3.8 2.3 21 6 23 305 6.7 0 6.9 6.4 09/10/2005 08:30:00 2.7 0.3 3.8 1.9 3 0.2 3.8 2.6 33 6 29 305 6.7 0 6.9 6.4 09/10/2005 08:40:00 2.7 0.3 3.4 2.3 3 0.3 3.8 2.3 49 6 51 305 6.7 0 6.9 6.4 09/10/2005 08:50:00 2.8 0.3 3.8 1.9 3.2 0.3 4.2 2.3 53 6 57 305 6.7 0 6.9 6.4 09/10/2005 09:00:00 3.1 0.3 3.8 2.3 3.3 0.3 4.2 2.3 55 6 57 305 6.8 0 7.2 6.7 09/10/2005 09:10:00 3.6 0.4 4.9 2.3 3.9 0.4 4.9 2.6 62 6 75 305 7.1 0.1 7.4 6.9 09/10/2005 09:20:00 3.6 0.3 4.2 2.6 3.8 0.3 4.6 3.4 62 5 55 305 7.3 0 7.7 7.4 09/10/2005 09:30:00 3.9 0.4 4.9 3 4.2 0.4 4.9 3.4 61 5 61 305 7.6 0 7.7 7.4 09/10/2005 09:40:00 4.4 0.4 5.3 3.4 4.6 0.3 5.3 3.8 63 4 72 305 7.7 0 8.4 7.7 09/10/2005 09:50:00 4.4 0.5 6.1 3.4 4.6 0.4 6.1 3.4 61 7 62 305 8.1 0 8.7 7.9 09/10/2005 10:00:00 4.6 0.5 5.7 3 4.7 0.5 6.1 3.4 60 6 72 305 8.2 0 8.7 8.2 09/10/2005 10:10:00 4.6 0.4 5.7 3.4 4.8 0.4 6.1 3.4 61 6 69 305 8.3 0.1 8.9 8.2 09/10/2005 10:20:00 4.7 0.7 6.5 3 4.7 0.7 6.5 3 69 8 71 305 8.5 0 8.9 8.2 09/10/2005 10:30:00 4.4 0.7 6.5 2.6 4.5 0.7 6.5 3 73 8 71 305 8.8 0 9.2 8.9 09/10/2005 10:40:00 3.8 0.6 5.7 2.3 3.8 0.5 5.3 2.6 80 9 79 305 9 0 9.2 8.9 09/10/2005 10:50:00 3.1 0.5 4.9 1.9 3.2 0.5 4.6 1.9 93 10 89 305 9.1 0 9.2 8.9 09/10/2005 11:00:00 3.3 0.6 4.6 1.5 3.5 0.5 4.9 2.3 82 9 80 305 9.1 0 9.2 8.9 09/10/2005 11:10:00 3.4 0.6 4.9 1.9 3.6 0.6 4.6 2.3 68 9 72 305 8.9 0 9.2 8.9 09/10/2005 11:20:00 3.7 0.5 4.6 2.3 3.8 0.5 4.6 2.6 72 8 74 305 9 0 9.2 8.9 09/10/2005 11:30:00 3.7 0.3 4.6 3 3.8 0.3 4.6 3 62 7 76 305 8.9 0.1 9.2 8.7 09/10/2005 11:40:00 3.6 0.3 4.2 2.6 3.7 0.3 4.6 3 71 9 57 305 8.9 0.1 9.2 8.7 09/10/2005 11:50:00 3.4 0.4 4.6 2.3 3.5 0.4 4.6 2.6 68 9 72 305 9.1 0 9.2 8.9 09/10/2005 12:00:00 3.4 0.5 4.6 2.3 3.5 0.4 4.6 2.3 62 6 62 305 9.1 0 9.2 8.9 09/10/2005 12:10:00 4 0.4 4.9 3 4 0.4 4.9 3 62 6 65 305 8.9 0 9.2 8.9 09/10/2005 12:20:00 4.4 0.4 5.3 3 4.4 0.4 5.3 3 71 6 75 305 9.2 0 9.5 8.9 09/10/2005 12:30:00 4.3 0.4 5.3 3 4.2 0.4 5.3 3 70 7 71 305 9.1 0 9.5 8.9 09/10/2005 12:40:00 4.1 0.6 5.7 2.3 4.1 0.6 5.7 2.6 77 10 77 305 9.4 0 9.7 9.2 09/10/2005 12:50:00 4.5 0.5 6.1 3 4.5 0.4 6.1 3.4 71 7 73 305 9.2 0 9.5 9.2 09/10/2005 13:00:00 3.9 0.5 4.9 2.6 3.9 0.5 4.9 2.6 74 12 71 305 9.1 0 9.5 8.9 09/10/2005 13:10:00 4 0.5 5.3 3 4 0.5 5.3 3 74 14 56 305 9.1 0 9.2 8.7 09/10/2005 13:20:00 4.6 0.4 5.7 3.8 4.6 0.4 5.7 3.4 63 7 78 305 8.6 0 8.7 8.2 09/10/2005 13:30:00 4.7 0.5 6.1 3.8 4.7 0.5 6.1 3.4 63 6 61 305 8.4 0 8.4 8.2 09/10/2005 13:40:00 5.1 0.4 6.1 3.8 5 0.4 6.1 3.8 61 4 57 305 8.2 0 8.4 8.2 09/10/2005 13:50:00 4.5 0.5 5.7 3.4 4.5 0.5 5.7 3.4 62 6 57 305 8.2 0 8.4 8.2 09/10/2005 14:00:00 3.9 0.5 4.9 2.6 3.8 0.5 4.9 2.6 64 9 70 305 8.3 0 8.9 8.2 09/10/2005 14:10:00 4.2 0.6 5.7 2.6 4.1 0.6 5.7 2.6 78 8 87 305 8.8 0.2 9.2 8.4 09/10/2005 14:20:00 5.2 0.5 6.8 3.8 5.1 0.5 6.1 3.8 69 7 74 305 9.3 0 9.5 8.9 09/10/2005 14:30:00 5.5 0.6 7.2 3.8 5.6 0.6 6.8 3.8 56 9 58 305 9 0.3 9.7 8.2 09/10/2005 14:40:00 5.5 0.4 6.5 4.6 5.6 0.4 6.8 4.6 54 7 53 305 8.2 0 8.4 7.9 09/10/2005 14:50:00 5.2 0.5 6.5 3.8 5.2 0.5 6.5 4.2 69 13 55 305 8.8 0.5 9.5 8.2 09/10/2005 15:00:00 5.2 0.5 6.8 3.8 5.1 0.4 6.5 4.2 73 9 51 305 9.3 0.1 9.7 9.2 09/10/2005 15:10:00 6 0.3 6.8 4.9 6.1 0.3 6.8 5.3 56 4 54 305 8.2 0.5 9.2 7.7 09/10/2005 15:20:00 5.9 0.4 6.8 4.9 5.8 0.4 6.8 4.6 57 5 57 305 7.8 0 7.9 7.7 09/10/2005 15:30:00 5.9 0.4 6.8 4.6 5.8 0.4 6.8 4.6 66 6 66 305 8.2 0.3 8.9 7.7 09/10/2005 15:40:00 5.8 0.4 6.8 4.6 5.7 0.4 6.8 4.6 74 5 72 305 9.1 0 9.2 8.9 09/10/2005 15:50:00 5.7 0.4 6.8 4.2 5.6 0.4 6.5 4.6 74 6 82 305 9.1 0 9.5 8.9 09/10/2005 16:00:00 5.2 0.4 6.1 3.8 5.2 0.5 6.5 3.8 80 7 85 305 9.4 0 9.7 9.2 09/10/2005 16:10:00 5.6 0.7 6.8 4.2 5.4 0.7 6.8 3.8 85 6 98 305 9.6 0 9.7 9.5 09/10/2005 16:20:00 6.7 0.6 8 4.9 6.5 0.6 7.6 4.9 88 5 87 305 9.5 0.2 9.7 9.2 09/10/2005 16:30:00 7.4 0.6 8.8 4.9 7.2 0.6 9.1 5.3 95 6 81 305 9 0 9.2 8.9 09/10/2005 16:40:00 7.8 0.6 9.1 5.7 7.6 0.6 8.8 6.1 97 6 112 305 8.9 0 9.2 8.9 09/10/2005 16:50:00 8 0.6 9.1 5.7 7.9 0.6 9.1 5.7 104 5 103 305 8.6 0 8.9 8.4 09/10/2005 17:00:00 7 0.8 8.8 4.9 6.9 0.8 9.1 4.9 104 9 90 305 8.4 0 8.7 8.2 09/10/2005 17:10:00 7 0.7 9.1 4.6 6.9 0.7 9.5 4.9 103 9 90 305 8.6 0 8.7 8.4 09/10/2005 17:20:00 6.2 0.8 8 4.2 6.1 0.8 8 4.2 96 8 90 305 8.8 0 9.2 8.7 09/10/2005 17:30:00 6.5 0.9 8.8 3.8 6.4 0.9 8.8 4.2 88 11 85 305 8.6 0 8.9 8.4 09/10/2005 17:40:00 5.9 1.2 9.1 3 6 1.1 9.1 3 84 17 75 305 8.6 0 8.9 8.2 09/10/2005 17:50:00 4.6 1 6.8 1.9 4.6 1 6.8 2.3 86 19 108 305 8.8 0 9.2 8.7 09/10/2005 18:00:00 5.2 0.9 7.6 2.6 5.4 0.9 8 3 90 20 62 305 8.6 0.2 8.9 8.2 09/10/2005 18:10:00 6.2 0.9 8.8 3.4 6.2 0.8 8.4 3.4 76 11 58 305 7.9 0.2 8.2 7.7 09/10/2005 18:20:00 5.9 0.6 7.6 4.2 5.8 0.6 8 3.8 85 9 90 305 8 0.1 8.2 7.7 09/10/2005 18:30:00 5.7 0.5 6.8 4.2 5.5 0.5 6.5 3.8 74 7 90 305 7.3 0.2 8.2 7.2 09/10/2005 18:40:00 6.8 0.7 8.4 5.3 6.6 0.7 8.4 4.9 74 5 74 305 7.1 0 7.2 6.9 09/10/2005 18:50:00 6.9 0.7 9.5 5.3 7 0.7 9.1 4.9 78 9 66 305 7 0 7.4 6.9 09/10/2005 19:00:00 7 0.5 8 5.3 6.9 0.5 8 5.7 82 5 60 305 7.5 0 7.7 7.4 09/10/2005 19:10:00 6.8 0.7 8.4 4.9 6.6 0.7 8.4 4.2 70 7 69 305 7 0.3 7.4 6.4 09/10/2005 19:20:00 7.3 0.8 9.9 5.7 7 0.8 9.5 4.6 75 8 80 305 6.8 0.2 7.4 6.4 09/10/2005 19:30:00 8 0.7 10.3 6.1 7.6 0.7 9.5 6.1 79 6 91 305 7.5 0 7.7 7.4 09/10/2005 19:40:00 7.7 1 9.9 4.2 7.5 1 9.9 4.6 73 9 82 305 7.5 0 7.7 7.4 09/10/2005 19:50:00 7.1 1.2 9.9 3.8 7.1 1.2 9.9 3.4 69 11 59 305 7.5 0 7.7 7.4 09/10/2005 20:00:00 7.8 1.3 11.8 4.6 7.9 1.2 12.2 4.6 76 11 83 305 7.5 0 7.7 7.4 09/10/2005 20:10:00 7.6 1.7 12.2 3 7.5 1.7 11.1 3.4 72 20 60 305 7.7 0 7.9 7.4 09/10/2005 20:20:00 6.1 1.8 11.8 1.5 6 1.8 11.5 0.4 102 22 98 305 8 0.2 8.4 7.7 09/10/2005 20:30:00 7 1.7 11.8 3.4 7 1.7 11.8 2.3 81 21 66 305 8.2 0 8.4 8.2 09/10/2005 20:40:00 7.2 1.7 11.8 3 7.1 1.6 11.5 3.4 97 26 99 305 8.4 0 8.7 8.2 09/10/2005 20:50:00 7.1 1.8 13.3 3 7.1 1.7 12.2 3.4 79 22 85 305 8.7 0 8.9 8.7 09/10/2005 21:00:00 8.4 1.5 12.2 5.3 8.6 1.5 12.2 4.6 72 13 62 305 8.5 0 8.7 8.4 09/10/2005 21:10:00 8.1 1.6 12.6 4.6 8.1 1.7 13 4.6 75 15 88 305 8.5 0 9.2 8.4 09/10/2005 21:20:00 8.4 1.7 14.5 4.2 8.1 1.6 12.6 3.4 77 13 73 305 8.4 0 8.9 8.2 09/10/2005 21:30:00 9.4 0.7 11.5 7.6 8.9 0.6 11.5 6.8 81 5 79 305 8.3 0.1 8.7 8.2 09/10/2005 21:40:00 9.9 0.8 12.2 7.2 9.3 0.8 11.8 6.8 82 5 80 305 8.2 0 8.4 7.9 09/10/2005 21:50:00 8.9 0.7 10.7 6.8 8.6 0.8 11.8 6.1 75 6 91 305 8 0 8.4 7.9 09/10/2005 22:00:00 9.8 1.2 13.7 6.8 9.6 1.3 14.1 6.1 72 8 72 305 7.9 0 8.4 7.9 09/10/2005 22:10:00 10.3 1.4 14.1 6.1 10.2 1.6 14.1 6.5 74 10 68 305 7.9 0.1 8.4 7.7 09/10/2005 22:20:00 10.4 1.4 15.3 6.8 10 1.5 17.6 6.5 72 8 61 305 7.9 0 8.4 7.7 09/10/2005 22:30:00 9.5 1.5 13.3 4.6 9.5 1.6 14.9 4.9 64 13 75 305 7.7 0.1 8.2 7.7 09/10/2005 22:40:00 9.8 2.1 16.4 5.3 9.6 2.2 16.8 4.2 68 18 52 305 8 0.1 8.7 7.7 09/10/2005 22:50:00 10.8 2.5 16.8 4.6 10.8 2.6 17.6 4.9 69 17 73 305 8.1 0 8.7 7.9 09/10/2005 23:00:00 10.8 1.9 16.4 4.9 11 2.1 16.8 4.9 64 13 69 305 8.1 0 8.7 7.9 09/10/2005 23:10:00 10.4 2.5 16.8 4.9 10.6 2.6 17.2 4.2 70 19 82 305 8 0 8.4 7.9 09/10/2005 23:20:00 10.6 1.7 15.3 6.5 10.5 2.1 15.3 5.7 70 14 74 305 7.9 0 8.4 7.9 09/10/2005 23:30:00 10.9 2 16.8 5.7 10.8 2.3 19.1 5.7 68 12 81 305 7.9 0 8.2 7.7 09/10/2005 23:40:00 10.4 2.1 16.8 5.3 10.4 2.3 16.8 4.9 66 15 70 305 7.8 0 8.2 7.7 09/10/2005 23:50:00 10.5 2.5 15.3 4.2 10.5 2.7 16.4 3.4 68 17 72 305 8 0 8.2 7.9 09/11/2005 00:00:00 9.2 2.3 14.5 3.8 8.9 2.6 15.3 3.4 70 22 58 305 8.2 0.1 8.7 8.2 09/11/2005 00:10:00 8.4 2.5 14.9 1.9 8.4 2.5 15.3 1.9 68 20 73 305 8.6 0 8.9 8.4 09/11/2005 00:20:00 9.4 2.9 16.8 3 9.3 3.1 16.4 3 65 20 68 305 8.6 0 8.9 8.4 09/11/2005 00:30:00 10.3 2.3 17.2 4.2 10.4 2.4 17.2 4.2 64 15 66 305 8.4 0 8.4 8.2 09/11/2005 00:40:00 11.2 2.1 15.6 5.3 11.2 2.2 16.1 5.7 63 14 68 305 8.6 0 8.7 8.4 09/11/2005 00:50:00 11.6 1.5 17.6 6.5 11.8 1.5 16.8 7.6 65 9 71 305 8.6 0 8.7 8.4 09/11/2005 01:00:00 11.1 1.5 14.9 7.2 11.3 1.6 15.3 7.2 66 9 65 305 8.7 0 8.9 8.7 09/11/2005 01:10:00 11.3 1.6 15.3 6.1 11.4 1.6 17.6 6.8 65 10 45 305 8.7 0 8.9 8.4 09/11/2005 01:20:00 10.5 1.5 15.6 6.1 10.6 1.5 15.3 5.7 68 8 85 305 8.4 0.1 8.7 8.2 09/11/2005 01:30:00 7.9 2.4 13.7 0.7 7.9 2.3 13.7 2.6 65 21 67 305 8.2 0 8.7 8.2 09/11/2005 01:40:00 6.7 2.2 12.6 0.4 6.6 2.1 13 2.3 66 26 73 305 8.6 0 8.9 8.4 09/11/2005 01:50:00 5.4 2 11.5 1.9 5.5 1.8 11.5 2.3 94 29 95 305 8.8 0.1 9.2 8.7 09/11/2005 02:00:00 7.4 2 14.1 2.6 7.5 2.1 14.5 3 60 15 59 305 8.8 0.1 9.2 8.4 09/11/2005 02:10:00 8.6 1.7 14.1 3.8 8.5 1.7 13.7 3.4 59 11 71 305 8.5 0.1 9.2 8.2 09/11/2005 02:20:00 6.9 1.8 12.2 2.3 6.9 2 12.2 2.3 56 23 54 305 8.6 0.1 9.2 8.2 09/11/2005 02:30:00 4.8 2.7 11.1 0.4 5 2.6 10.7 0.7 68 41 48 305 8.7 0 9.2 8.4 09/11/2005 02:40:00 4 1.7 11.5 0.4 3.8 1.6 9.5 0.4 80 43 121 305 8.8 0.1 9.2 8.4 09/11/2005 02:50:00 6.1 2.2 13 1.1 5.9 2.2 14.5 2.6 120 29 133 305 9.1 0 9.7 8.9 09/11/2005 03:00:00 5.1 2.3 13 0.7 4.8 2.1 12.2 0.7 102 38 85 305 9.2 0.1 9.7 9.2 09/11/2005 03:10:00 6.4 2.4 13.3 0.7 6.1 2.1 13.3 1.9 105 36 132 305 9.3 0.1 9.7 9.2 09/11/2005 03:20:00 4.3 2 10.3 0.4 4.3 1.9 9.9 0.4 105 41 127 305 9.3 0.1 9.7 9.2 09/11/2005 03:30:00 5.9 2 11.8 1.5 5.5 2 12.2 1.9 90 32 112 305 9.3 0.1 9.7 9.2 09/11/2005 03:40:00 7.7 2.2 13.3 2.6 7.7 2.2 13.7 2.3 64 21 51 305 9.1 0 9.7 8.9 09/11/2005 03:50:00 7.2 2.1 12.6 1.9 7.1 2.1 11.8 2.3 68 23 65 305 8.9 0.1 9.5 8.9 09/11/2005 04:00:00 7.4 2.2 14.1 3 7.3 2 13.7 0.7 61 24 61 305 8.8 0 9.2 8.7 09/11/2005 04:10:00 5.2 1.7 9.5 0.4 5.1 1.7 9.5 1.5 77 35 75 305 8.6 0 9.2 8.4 09/11/2005 04:20:00 4.5 2.1 11.1 0.4 4.1 2 10.7 0.4 74 45 47 305 8.6 0 9.2 8.4 09/11/2005 04:30:00 5.1 1.7 9.5 0.4 5.3 1.7 9.9 0.7 64 27 50 305 8.7 0 8.9 8.4 09/11/2005 04:40:00 4.3 2.1 9.9 0.4 4.3 1.8 9.5 0.4 77 45 17 305 8.6 0 8.9 8.4 09/11/2005 04:50:00 2.9 1.6 7.2 0.4 3 1.3 7.2 0.4 79 47 44 305 8.6 0 8.9 8.4 09/11/2005 05:00:00 3.4 1.7 8.8 0.4 3.5 1.5 9.1 0.4 73 35 120 305 8.8 0 8.9 8.7 09/11/2005 05:10:00 4.1 1.7 11.1 0.7 4.2 1.4 9.9 1.5 74 43 126 305 8.8 0 9.2 8.7 09/11/2005 05:20:00 3.2 1.9 7.2 0.4 3.2 1.6 7.6 0.4 82 64 138 305 8.9 0 9.2 8.9 09/11/2005 05:30:00 5.3 1.9 12.6 0.4 5.2 2 12.2 0.4 54 29 61 305 8.9 0 9.2 8.9 09/11/2005 05:40:00 8 2.6 15.3 2.6 8.1 2.7 15.3 2.3 61 22 70 305 9.1 0 9.2 8.7 09/11/2005 05:50:00 8.4 2.1 15.6 2.3 8.5 2 16.8 2.6 57 14 35 305 8.2 0.1 8.7 8.2 09/11/2005 06:00:00 7.6 2.2 13.3 2.6 7.6 2.3 14.1 2.3 58 20 72 305 8.3 0 8.9 8.2 09/11/2005 06:10:00 6.9 2.4 13 1.5 6.8 2.3 13.3 2.3 68 29 58 305 8.7 0 8.9 8.4 09/11/2005 06:20:00 5.8 2.4 13 0.4 5.6 2.3 11.5 0.7 96 49 112 305 8.8 0.1 9.5 8.7 09/11/2005 06:30:00 5.2 2.1 10.3 0.4 5 2 10.7 1.1 71 41 56 305 8.8 0.1 9.5 8.9 09/11/2005 06:40:00 5.2 2.5 11.5 0.4 5.3 2.5 11.5 0.4 71 32 48 305 8.8 0.1 9.5 8.7 09/11/2005 06:50:00 6.5 2.2 11.8 0.7 6.3 2.3 11.1 1.5 63 29 61 305 8.7 0 9.2 8.7 09/11/2005 07:00:00 4.4 2.1 9.9 0.4 4.4 2 9.9 0.7 81 45 72 305 8.8 0 9.2 8.7 09/11/2005 07:10:00 5.2 2 12.2 0.4 5.1 2 11.5 0.7 80 45 59 305 8.7 0 9.2 8.4 09/11/2005 07:20:00 5.9 1.8 9.5 0.4 5.7 1.7 10.3 1.1 62 30 66 305 8.7 0 9.2 8.7 09/11/2005 07:30:00 5.3 2 10.3 0.4 5.2 1.7 9.5 1.5 67 49 30 305 8.7 0 9.2 8.7 09/11/2005 07:40:00 5.8 2.4 11.5 0.4 5.8 2.3 11.5 0.7 74 32 53 305 8.7 0 9.2 8.7 09/11/2005 07:50:00 5.9 2.4 11.5 0.4 5.8 2.1 10.7 0.4 75 43 37 305 8.8 0 9.2 8.7 09/11/2005 08:00:00 7.7 2.3 13.3 2.6 7.7 2.3 13.7 3 60 20 57 305 8.6 0 8.9 8.4 09/11/2005 08:10:00 6.6 2.4 14.5 1.5 6.6 2.4 13.3 1.5 67 32 54 305 8.4 0 8.9 8.2 09/11/2005 08:20:00 6.7 1.9 11.1 1.5 6.6 1.9 12.6 2.3 59 23 67 305 8.7 0 9.2 8.4 09/11/2005 08:30:00 8.1 2.2 14.5 2.6 8.3 2.1 14.1 3.8 52 16 46 305 8.6 0 9.2 8.2 09/11/2005 08:40:00 9.1 2.1 15.6 3.8 9.2 2.3 14.5 3.8 62 15 61 305 8 0 8.4 7.9 09/11/2005 08:50:00 8.9 1.7 13 4.6 8.9 1.7 13.3 5.7 68 12 64 305 7.9 0 8.2 7.9 09/11/2005 09:00:00 10.9 2.1 17.9 5.7 11 2.2 16.1 4.9 64 12 65 305 8.2 0.1 8.4 7.9 09/11/2005 09:10:00 12.1 1.7 16.4 5.7 12.3 1.6 16.4 7.2 65 7 79 305 8.3 0 8.4 8.2 09/11/2005 09:20:00 12 1.3 16.8 8.4 12 1.4 16.1 8.4 66 7 63 305 8.2 0 8.4 8.2 09/11/2005 09:30:00 12 1.7 16.4 4.9 12.1 1.7 16.1 5.7 66 9 62 305 8.3 0 8.4 8.2 09/11/2005 09:40:00 10.5 2.1 17.2 4.9 10.6 2.1 17.6 4.9 61 12 73 305 8.2 0 8.4 8.2 09/11/2005 09:50:00 8.6 2.8 16.1 1.1 8.4 2.8 16.4 0.7 68 27 62 305 8.1 0 8.2 7.9 09/11/2005 10:00:00 7.7 2.6 14.5 1.9 7.8 2.8 14.5 2.6 71 27 64 305 8.1 0 8.2 7.9 09/11/2005 10:10:00 7.1 2 11.5 1.5 7 1.7 12.6 3.4 64 32 79 305 8.1 0 8.2 8.2 09/11/2005 10:20:00 6.6 2 13.3 0.7 6.5 2 13.3 2.6 65 23 54 305 8.1 0 8.2 7.9 09/11/2005 10:30:00 7.5 2.4 12.2 1.1 7.5 2.4 13.3 1.9 62 21 52 305 8 0 8.2 7.9 09/11/2005 10:40:00 7.3 2.5 14.5 2.3 7.3 2.3 14.9 3.4 60 17 68 305 8 0 8.2 7.9 09/11/2005 10:50:00 7.4 2.2 14.9 2.3 7.4 2.3 15.3 1.5 65 24 64 305 8 0 8.4 7.9 09/11/2005 11:00:00 9.7 2.7 15.6 3 9.8 2.8 16.1 3 64 21 60 305 8.1 0 8.7 7.9 09/11/2005 11:10:00 8.9 2.6 17.9 3 8.7 2.7 16.4 2.6 67 20 62 305 8.2 0.1 8.7 8.2 09/11/2005 11:20:00 9.2 2 15.3 4.6 9.3 2.2 16.8 4.2 69 26 39 305 8.3 0.1 8.9 8.2 09/11/2005 11:30:00 8 2.2 14.9 1.5 7.8 2.5 16.8 1.5 74 24 62 305 8.4 0 8.9 8.4 09/11/2005 11:40:00 8 2.3 14.1 3 7.9 2.5 15.6 3 63 22 54 305 8.5 0 8.9 8.4 09/11/2005 11:50:00 8.3 2.4 15.3 1.9 8 2.6 15.6 2.3 68 22 64 305 8.5 0 8.9 8.4 09/11/2005 12:00:00 8.5 2.4 16.8 3 8.6 2.4 14.9 3 60 19 60 305 8.4 0 8.9 8.2 09/11/2005 12:10:00 8.6 2.5 15.3 0.4 8.5 2.7 16.1 1.5 64 23 62 305 8.2 0.1 8.7 8.2 09/11/2005 12:20:00 8.4 2.6 14.5 3 8.3 2.6 16.1 2.3 63 17 58 305 8.2 0.1 8.7 8.2 09/11/2005 12:30:00 10 2.3 16.1 3.4 10.1 2.4 17.2 4.2 61 12 66 305 8.2 0.1 8.9 8.2 09/11/2005 12:40:00 9.6 2.4 17.2 3.8 10 2.5 16.4 4.6 59 16 46 305 8.2 0 8.7 8.2 09/11/2005 12:50:00 9.5 2.4 15.3 3.8 9.3 2.5 15.3 3.4 63 14 65 305 8.2 0 8.7 8.2 09/11/2005 13:00:00 9.6 2.6 17.6 4.2 9.4 2.6 17.6 3.8 68 22 61 305 8.2 0 8.7 8.2 09/11/2005 13:10:00 9.1 2.3 16.1 4.2 9.1 2.4 15.3 4.2 63 17 64 305 8.1 0 8.4 7.9 09/11/2005 13:20:00 9.1 1.9 14.1 3.4 9.1 2.2 15.6 4.2 62 15 51 305 8.1 0 8.2 7.9 09/11/2005 13:30:00 8.6 2.2 14.5 3.4 8.5 2.3 14.5 3 66 18 57 305 8.1 0 8.2 7.9 09/11/2005 13:40:00 8.4 2 14.1 4.2 8 2.3 14.9 3.8 67 15 61 305 8 0 8.2 7.9 09/11/2005 13:50:00 8.6 1.7 13.3 3.8 8.6 1.8 14.1 3.4 63 16 56 305 8 0 8.2 7.9 09/11/2005 14:00:00 8.6 2.2 15.3 3.4 8.3 2.4 16.4 2.3 67 18 70 305 8.1 0 8.2 7.9 09/11/2005 14:10:00 8.6 1.9 14.1 3 8.6 2.2 14.5 3.4 65 17 71 305 8.2 0 8.2 7.9 09/11/2005 14:20:00 8.4 1.7 14.9 4.6 8.2 1.9 14.5 1.5 69 17 82 305 8.1 0 8.2 8.2 09/11/2005 14:30:00 8.6 1.8 12.6 3 8.4 1.8 13 3.8 68 15 76 305 8.1 0 8.2 7.9 09/11/2005 14:40:00 9.3 1.7 13.7 6.1 9.1 1.9 13.3 5.3 70 15 71 305 8.1 0 8.2 7.9 09/11/2005 14:50:00 9.7 1.9 14.5 5.3 9.7 1.9 15.6 5.7 70 12 55 305 8.1 0 8.2 8.2 09/11/2005 15:00:00 9.8 1.6 16.1 5.3 9.7 1.7 14.5 5.7 72 13 67 305 8.2 0 8.4 8.2 09/11/2005 15:10:00 10.1 1.5 15.3 6.1 10 1.6 14.1 6.5 71 11 80 305 8.2 0 8.4 8.2 09/11/2005 15:20:00 9.9 1.6 14.5 4.9 9.6 1.7 14.5 6.1 73 11 65 305 8.2 0 8.2 8.2 09/11/2005 15:30:00 8.8 1.6 15.3 4.9 8.5 1.8 15.6 4.6 73 14 71 305 8.2 0.1 8.7 8.2 09/11/2005 15:40:00 8 1.8 13.3 4.2 7.8 1.8 13.3 3.8 73 18 53 305 8.2 0 8.7 8.2 09/11/2005 15:50:00 5 1.7 9.9 0.4 4.8 1.6 9.1 1.5 97 27 78 305 8.1 0 8.7 7.9 09/11/2005 16:00:00 4.9 1.1 8 2.3 4.7 1 7.2 2.6 112 17 99 305 8.3 0.1 8.9 8.2 09/11/2005 16:10:00 5.5 1.2 8.8 2.3 5.3 1.1 8 2.3 124 13 134 305 8.6 0 9.2 8.4 09/11/2005 16:20:00 5.2 1.1 8.8 2.6 5.2 1 8 3.4 137 12 148 305 8.9 0.1 9.5 8.7 09/11/2005 16:30:00 5.5 1.2 8.4 1.9 5.6 1 8 1.9 145 13 143 305 9 0 9.5 8.9 09/11/2005 16:40:00 6.1 1.1 9.1 3 6.1 1 9.1 3.4 144 12 145 305 9.1 0 9.7 8.9 09/11/2005 16:50:00 6.7 1.2 10.3 3.4 6.8 1 9.5 4.6 149 13 149 305 9 0.1 9.7 8.9 09/11/2005 17:00:00 6.3 1.2 9.1 3.8 6.5 1 9.5 4.6 151 10 152 305 8.8 0.1 9.5 8.7 09/11/2005 17:10:00 6.5 1.6 10.7 3 6.6 1.3 10.7 3.8 151 12 136 305 8.8 0.1 9.5 8.7 09/11/2005 17:20:00 4.9 1.3 8.4 2.3 5.5 1.1 9.1 3 160 13 151 305 8.7 0 9.2 8.4 09/11/2005 17:30:00 5.1 1.1 8.4 2.3 5.9 0.9 8.4 3.4 159 12 147 305 8.6 0 9.2 8.4 09/11/2005 17:40:00 5.4 1.4 9.1 1.5 5.6 1 8.4 3.4 153 12 139 305 8.5 0 8.9 8.4 09/11/2005 17:50:00 6.2 1.2 9.9 2.6 6.2 1.1 9.1 3.4 148 10 160 305 8.5 0 8.9 8.4 09/11/2005 18:00:00 5.6 0.8 8 3 5.7 0.7 7.6 3.8 148 11 147 305 8.4 0 8.4 8.2 09/11/2005 18:10:00 6.2 0.9 8.4 3.8 6.1 0.8 8.4 4.2 135 9 119 305 8.2 0 8.4 8.2 09/11/2005 18:20:00 6.3 0.7 8.4 4.2 6.2 0.7 7.6 4.6 135 7 131 305 8.2 0 8.4 8.2 09/11/2005 18:30:00 5.5 1 8 3 5.5 1 7.6 3.4 135 11 130 305 8.2 0 8.2 8.2 09/11/2005 18:40:00 3.8 1.1 6.5 1.1 3.9 1 6.5 1.9 131 16 130 305 8.2 0 8.2 8.2 09/11/2005 18:50:00 3.8 0.9 6.1 1.5 3.9 0.9 6.1 1.9 118 18 90 305 8.2 0 8.4 8.2 09/11/2005 19:00:00 2.7 1.3 6.1 0.4 2.9 1.1 6.1 0.4 121 22 142 305 8.2 0 8.4 8.2 09/11/2005 19:10:00 1.6 1 4.6 0.4 1.9 0.9 4.6 0.4 98 41 81 305 8.2 0 8.2 8.2 09/11/2005 19:20:00 2.4 1.2 5.3 0.4 2.5 1.1 4.9 0.4 68 28 88 305 8.1 0 8.2 8.2 09/11/2005 19:30:00 3.8 0.9 7.6 1.9 3.8 0.9 7.2 1.9 108 28 96 305 8.1 0 8.2 7.9 09/11/2005 19:40:00 2.1 0.9 4.2 0.4 2.3 1 4.6 0.4 77 33 105 305 8 0 8.2 7.9 09/11/2005 19:50:00 3.7 0.9 5.7 1.9 3.9 1 6.1 1.5 62 22 62 305 8 0 8.2 7.9 09/11/2005 20:00:00 3.4 1.3 7.2 0.7 3.4 1.3 6.8 0.7 82 22 35 305 8 0 8.4 7.9 09/11/2005 20:10:00 3.8 1.4 7.6 0.7 3.8 1.3 7.6 0.7 77 20 80 305 8 0.1 8.7 7.9 09/11/2005 20:20:00 4.7 1.5 8.8 1.5 4.8 1.4 8.4 1.9 66 18 57 305 8.2 0.1 8.9 7.9 09/11/2005 20:30:00 5.7 1.1 8 2.6 5.7 1 8 3 69 14 88 305 8 0.2 8.7 7.4 09/11/2005 20:40:00 6.5 0.8 9.1 4.6 6.3 0.7 8.4 4.6 74 10 72 305 7.4 0 7.7 7.2 09/11/2005 20:50:00 7.4 0.9 9.5 4.9 7 0.9 9.9 4.2 83 8 80 305 7.6 0 7.7 7.4 09/11/2005 21:00:00 7.4 0.9 10.3 5.3 7.3 0.9 9.9 5.3 80 10 87 305 7.6 0 7.7 7.7 09/11/2005 21:10:00 8.2 0.8 9.9 5.7 8.1 0.7 10.3 6.1 80 6 62 305 7.7 0 8.2 7.7 09/11/2005 21:20:00 9.1 0.9 11.1 6.1 8.8 0.9 11.1 6.8 80 5 85 305 7.7 0 7.9 7.7 09/11/2005 21:30:00 10.6 0.7 12.6 8.4 10.3 0.8 12.2 7.6 80 4 75 305 7.9 0 8.2 7.7 09/11/2005 21:40:00 10.9 0.9 13.3 8 10.4 0.9 13 8.4 82 6 87 305 8 0 8.4 7.9 09/11/2005 21:50:00 11.1 0.9 13 8.8 10.8 1 13.3 8.4 75 6 76 305 7.8 0.1 8.2 7.7 09/11/2005 22:00:00 11.2 1 15.6 8 10.9 1 14.1 8 76 7 75 305 7.6 0 7.7 7.7 09/11/2005 22:10:00 10.6 1.1 13.7 7.6 10.2 1.1 13.7 7.6 77 8 74 305 7.6 0 7.7 7.4 09/11/2005 22:20:00 10.8 1.1 14.1 8.4 10.5 1.1 13.3 7.6 76 8 65 305 7.7 0 7.9 7.7 09/11/2005 22:30:00 11.4 1.3 14.9 8 11 1.5 14.5 7.2 78 9 65 305 7.8 0 8.2 7.7 09/11/2005 22:40:00 12 1.3 16.1 8.8 11.6 1.4 15.6 8.8 80 8 74 305 8 0 8.2 7.9 09/11/2005 22:50:00 11.7 1 14.9 8.8 11.3 1.1 14.5 8.4 77 7 89 305 8 0 8.2 7.9 09/11/2005 23:00:00 11.1 1 13.7 8.4 10.7 1.1 14.1 8 73 7 81 305 7.9 0 7.9 7.7 09/11/2005 23:10:00 11 1 13.3 8 10.7 1.1 13.7 8 73 6 66 305 7.9 0 7.9 7.7 09/11/2005 23:20:00 10.5 1 12.6 7.2 9.9 1.1 12.6 6.8 69 6 71 305 7.8 0.1 8.2 7.7 09/11/2005 23:30:00 9.8 1.5 12.6 6.5 9.2 1.5 12.6 5.7 66 8 71 305 7.5 0 7.7 7.4 09/11/2005 23:40:00 10.9 1 13.3 8.4 10.1 1.1 13.3 6.8 68 6 67 305 7.5 0 7.7 7.4 09/11/2005 23:50:00 11.6 1.1 14.1 7.6 11 1.2 13.7 7.6 69 5 72 305 7.6 0 7.9 7.7 09/12/2005 00:00:00 9.4 1.2 12.2 6.1 9 1.1 11.8 5.7 64 7 70 305 7.4 0 8.2 7.2 09/12/2005 00:10:00 7.6 0.8 9.9 5.7 7.2 0.7 9.5 5.7 60 6 65 305 7 0 7.4 6.9 09/12/2005 00:20:00 7.8 0.4 8.8 6.8 7.6 0.4 8.8 6.8 58 3 56 305 6.9 0 7.2 6.9 09/12/2005 00:30:00 8 0.5 9.5 6.8 7.8 0.4 9.1 6.8 56 3 56 305 6.8 0 7.2 6.9 09/12/2005 00:40:00 9.5 0.6 11.5 7.2 9.1 0.7 10.7 7.2 54 4 59 305 7 0 7.2 6.9 09/12/2005 00:50:00 9.4 0.5 10.7 8 9.1 0.5 10.7 8 56 3 52 305 7 0 7.2 6.9 09/12/2005 01:00:00 9 0.4 10.7 7.6 8.7 0.5 10.3 7.2 57 4 52 305 7 0 7.2 6.9 09/12/2005 01:10:00 10.4 0.7 12.2 8.8 9.9 0.8 11.8 7.6 53 4 57 305 7 0 7.2 6.9 09/12/2005 01:20:00 10.5 0.6 12.6 8.8 10.1 0.7 12.2 8.4 55 4 55 305 7 0 7.2 6.9 09/12/2005 01:30:00 11.3 0.6 12.6 9.5 10.8 0.7 12.6 8.8 53 4 48 305 7 0 7.2 7.2 09/12/2005 01:40:00 10.9 1.2 13.7 8 10.5 1.3 13.3 7.6 52 4 53 305 7 0 7.2 6.9 09/12/2005 01:50:00 10.7 0.6 12.6 9.1 10.3 0.8 12.2 6.5 49 4 53 305 6.9 0 7.2 6.9 09/12/2005 02:00:00 10.9 0.6 12.2 9.1 10.5 0.6 12.2 8.4 53 4 58 305 7 0 7.2 6.9 09/12/2005 02:10:00 11.6 0.6 13 9.5 11.1 0.7 13 9.1 51 4 50 305 7 0 7.2 6.9 09/12/2005 02:20:00 11.8 0.6 13.7 10.3 11.2 0.6 13 9.1 51 4 57 305 7 0 7.2 6.9 09/12/2005 02:30:00 11.9 0.6 13.7 10.3 11.4 0.7 13 9.1 49 4 51 305 7 0 7.2 6.9 09/12/2005 02:40:00 11.9 0.7 13.7 10.3 11.4 0.7 13 9.1 48 4 49 305 7 0 7.2 6.9 09/12/2005 02:50:00 11.9 0.6 13.3 10.3 11.5 0.7 13.3 9.5 47 4 48 305 6.8 0 7.2 6.9 09/12/2005 03:00:00 12.2 0.8 14.5 10.3 11.8 0.8 14.5 9.9 44 4 42 305 6.9 0 7.2 6.9 09/12/2005 03:10:00 12.5 0.6 14.1 10.7 12.1 0.7 13.7 9.9 43 5 47 305 6.8 0 7.2 6.9 09/12/2005 03:20:00 12.8 0.7 14.9 10.7 12.4 0.7 14.5 10.3 41 4 41 305 6.8 0 7.2 6.9 09/12/2005 03:30:00 13.1 0.7 14.9 11.5 12.7 0.8 15.3 10.3 41 4 41 305 6.8 0 6.9 6.7 09/12/2005 03:40:00 13 0.8 15.3 11.1 12.6 0.8 14.5 10.7 40 4 44 305 6.7 0 6.9 6.7 09/12/2005 03:50:00 13.3 0.8 15.6 11.5 13 0.8 15.3 11.1 40 4 40 305 6.7 0 6.9 6.7 09/12/2005 04:00:00 13.6 0.8 16.1 11.5 13.3 0.9 15.6 11.1 39 4 32 305 6.8 0 6.9 6.7 09/12/2005 04:10:00 13.3 0.8 15.3 11.1 13 0.9 15.6 11.1 40 4 42 305 6.7 0 6.9 6.7 09/12/2005 04:20:00 13.2 0.9 15.6 11.5 12.9 0.9 15.6 11.1 39 4 36 305 6.7 0 6.9 6.7 09/12/2005 04:30:00 13.6 0.9 16.1 11.8 13.2 0.9 15.3 11.1 41 4 45 305 6.8 0 6.9 6.7 09/12/2005 04:40:00 13.8 0.7 15.3 11.8 13.3 0.8 15.3 11.5 39 4 36 305 6.8 0 6.9 6.9 09/12/2005 04:50:00 13.6 0.8 16.1 11.5 13.2 0.9 15.3 11.1 40 4 45 305 6.8 0 7.2 6.9 09/12/2005 05:00:00 13.1 0.7 14.9 11.1 12.7 0.8 14.5 10.3 39 4 36 305 6.8 0 6.9 6.7 09/12/2005 05:10:00 12.7 0.7 14.5 10.7 12.4 0.8 14.1 10.3 40 4 41 305 6.8 0 6.9 6.7 09/12/2005 05:20:00 12.6 0.7 14.5 10.3 12.3 0.7 14.1 10.3 38 4 42 305 6.8 0 6.9 6.7 09/12/2005 05:30:00 12.4 0.7 14.5 10.3 12 0.7 13.7 10.3 40 4 44 305 6.8 0 6.9 6.7 09/12/2005 05:40:00 12.3 0.7 14.1 9.9 11.9 0.7 13.7 9.9 38 4 42 305 6.7 0 6.9 6.7 09/12/2005 05:50:00 12.6 0.7 14.5 11.1 12.3 0.8 14.5 10.3 35 4 32 305 6.8 0 6.9 6.7 09/12/2005 06:00:00 12.7 0.8 14.9 10.3 12.3 0.8 14.5 9.9 33 3 42 305 6.8 0 7.2 6.7 09/12/2005 06:10:00 11.8 0.8 13.3 8.8 11.5 0.8 13 8.8 34 4 34 305 6.8 0 6.9 6.7 09/12/2005 06:20:00 12.5 0.6 14.5 10.3 12.1 0.7 14.1 10.3 33 3 31 305 6.8 0 6.9 6.7 09/12/2005 06:30:00 12.2 0.7 14.1 10.3 11.8 0.8 13.7 9.5 34 3 39 305 6.8 0 7.2 6.9 09/12/2005 06:40:00 11.4 0.5 13 9.9 11.1 0.6 12.6 9.5 34 3 32 305 6.8 0 7.2 6.9 09/12/2005 06:50:00 11 0.5 13 9.5 10.7 0.6 12.2 9.1 36 4 41 305 6.8 0 7.2 6.9 09/12/2005 07:00:00 10.6 0.5 11.8 9.5 10.3 0.6 11.5 8.4 35 3 33 305 6.8 0 7.2 6.9 09/12/2005 07:10:00 10.8 0.4 11.8 9.5 10.3 0.5 11.5 9.1 34 3 32 305 6.8 0 7.2 6.9 09/12/2005 07:20:00 10.2 0.4 11.5 8.8 9.8 0.5 11.5 8 32 3 32 305 6.8 0 7.2 6.9 09/12/2005 07:30:00 10 0.5 11.5 8.8 9.7 0.5 11.1 8.4 33 2 32 305 6.8 0 7.2 6.9 09/12/2005 07:40:00 9.3 0.4 10.3 8.4 9 0.4 9.9 8 33 3 30 305 6.8 0 6.9 6.9 09/12/2005 07:50:00 8.8 0.4 9.9 7.6 8.5 0.4 9.5 7.2 33 3 32 305 6.8 0 6.9 6.7 09/12/2005 08:00:00 8.5 0.3 9.1 7.6 8.3 0.3 9.5 7.2 32 2 33 305 6.8 0 6.9 6.9 09/12/2005 08:10:00 8.2 0.3 9.1 7.2 8 0.3 8.8 7.2 32 3 27 305 6.8 0 6.9 6.9 09/12/2005 08:20:00 7.6 0.4 8.8 6.8 7.4 0.3 8.4 6.5 30 3 36 305 6.8 0 6.9 6.7 09/12/2005 08:30:00 7.4 0.3 8.4 6.5 7.3 0.3 8 6.5 27 3 29 305 6.9 0 7.2 6.9 09/12/2005 08:40:00 7 0.3 7.6 6.1 6.9 0.3 8 6.1 23 3 26 305 6.9 0 7.2 6.9 09/12/2005 08:50:00 6.7 0.3 7.2 5.7 6.6 0.3 7.2 5.7 20 3 20 305 7 0 7.2 6.9 09/12/2005 09:00:00 6.2 0.3 7.2 5.3 6.1 0.3 6.8 4.9 20 2 18 305 7 0 7.2 6.9 09/12/2005 09:10:00 6.1 0.4 7.2 5.3 6.1 0.4 7.2 5.3 21 2 26 305 7 0 7.2 6.9 09/12/2005 09:20:00 5.7 0.4 6.5 4.9 5.7 0.4 6.5 4.9 20 4 22 305 7 0 7.2 7.2 09/12/2005 09:30:00 5.8 0.3 6.8 4.9 5.8 0.3 6.5 4.9 15 3 19 305 7 0 7.2 6.9 09/12/2005 09:40:00 5.9 0.3 6.5 4.9 6 0.3 6.8 5.3 12 2 15 305 7 0 7.2 7.2 09/12/2005 09:50:00 6.2 0.3 6.8 5.7 6.3 0.4 7.2 5.3 9 3 7 305 7.1 0 7.4 7.2 09/12/2005 10:00:00 6 0.2 6.8 4.9 6.1 0.3 6.8 5.3 5 3 7 305 7.2 0 7.4 7.2 09/12/2005 10:10:00 6.1 0.2 6.8 5.7 6.1 0.3 6.8 5.3 5 2 2 305 7.2 0 7.7 7.2 09/12/2005 10:20:00 5.9 0.3 6.5 4.9 5.9 0.3 6.5 4.9 2 3 11 305 7.3 0 7.4 7.2 09/12/2005 10:30:00 6.1 0.3 6.8 5.3 6 0.3 6.8 5.3 358 3 355 305 7.3 0 7.4 7.2 09/12/2005 10:40:00 6.1 0.3 6.5 5.3 6.1 0.3 6.8 5.3 355 2 0 305 7.3 0 7.4 7.2 09/12/2005 10:50:00 6.1 0.3 6.5 5.3 6.1 0.3 6.8 4.9 357 2 354 305 7.2 0 7.7 7.2 09/12/2005 11:00:00 5.9 0.3 6.8 4.9 5.9 0.3 6.8 4.9 357 2 357 305 7.2 0 7.4 7.2 09/12/2005 11:10:00 5.7 0.3 6.5 4.9 5.8 0.4 6.8 4.6 356 3 359 305 7.3 0 7.4 7.2 09/12/2005 11:20:00 5.5 0.3 6.1 4.6 5.6 0.3 6.5 4.6 351 3 354 305 7.3 0 7.4 7.2 09/12/2005 11:30:00 5.3 0.3 5.7 4.6 5.4 0.3 6.1 4.6 347 2 348 305 7.3 0 7.7 7.4 09/12/2005 11:40:00 5.2 0.3 5.7 4.6 5.3 0.3 6.1 4.6 344 3 345 305 7.4 0 7.9 7.4 09/12/2005 11:50:00 5 0.3 5.7 4.2 5 0.4 6.1 3.8 338 5 341 305 7.5 0 7.9 7.4 09/12/2005 12:00:00 4.9 0.3 5.7 4.2 4.9 0.4 5.7 3.4 334 3 340 305 7.5 0 7.7 7.4 09/12/2005 12:10:00 5.3 0.3 6.1 4.6 5.2 0.3 6.1 4.2 333 3 333 305 7.5 0 7.7 7.4 09/12/2005 12:20:00 5.5 0.3 6.1 4.6 5.5 0.4 6.5 4.2 338 3 336 305 7.5 0 7.7 7.4 09/12/2005 12:30:00 5.6 0.3 6.5 4.9 5.6 0.3 6.5 4.6 341 3 342 305 7.3 0 7.7 7.2 09/12/2005 12:40:00 5.4 0.3 6.1 4.6 5.4 0.3 6.1 4.6 344 3 347 305 7.3 0 7.4 7.2 09/12/2005 12:50:00 5.2 0.2 5.7 4.6 5.3 0.3 6.1 4.2 342 3 346 305 7.2 0 7.4 7.2 09/12/2005 13:00:00 5.1 0.2 5.7 4.6 5.2 0.3 5.7 4.2 341 2 340 305 7.2 0 7.4 7.2 09/12/2005 13:10:00 4.8 0.3 5.3 3.8 4.8 0.4 5.7 4.2 336 3 338 305 7.2 0 7.4 7.2 09/12/2005 13:20:00 4.8 0.3 5.3 4.2 4.8 0.3 5.7 4.2 328 5 324 305 7.2 0 7.4 7.2 09/12/2005 13:30:00 5.1 0.3 5.7 4.2 5 0.3 5.7 3.8 324 3 330 305 7.2 0 7.4 7.2 09/12/2005 13:40:00 5 0.3 5.7 4.2 4.9 0.4 5.7 3.8 323 4 317 305 7.3 0 7.4 7.2 09/12/2005 13:50:00 4.8 0.3 5.3 3.8 4.7 0.4 5.3 3.4 318 5 326 305 7.2 0 7.4 7.2 09/12/2005 14:00:00 4.4 0.4 5.3 3.4 4.3 0.4 5.3 3.4 310 11 305 305 7.2 0 7.4 7.2 09/12/2005 14:10:00 4.6 0.4 5.3 3 4.5 0.4 5.7 3.4 310 23 305 305 7.1 0 7.4 7.2 09/12/2005 14:20:00 5.2 0.4 6.1 3.8 5 0.4 6.1 3.8 313 21 304 305 7 0 7.4 7.2 09/12/2005 14:30:00 5.5 0.3 6.1 4.6 5.3 0.4 6.1 4.2 313 7 305 305 7 0 7.2 6.9 09/12/2005 14:40:00 5.3 0.4 6.1 4.2 5 0.4 6.1 3.8 312 15 309 305 7 0 7.2 6.9 09/12/2005 14:50:00 5.7 0.6 6.8 4.2 5.3 0.6 6.5 3.8 311 20 308 305 7 0 7.2 6.9 09/12/2005 15:00:00 5.4 0.5 6.5 4.2 5.1 0.5 6.1 3.8 313 22 315 305 7 0 7.2 6.9 09/12/2005 15:10:00 5.4 0.6 7.2 4.2 5.2 0.6 6.8 3.8 306 18 297 305 6.9 0 7.2 6.9 09/12/2005 15:20:00 5.6 0.5 6.8 4.2 5.3 0.5 6.5 3.8 312 23 304 305 7 0 7.2 6.9 09/12/2005 15:30:00 5.7 0.5 6.8 4.6 5.4 0.5 6.5 3.8 310 19 306 305 6.8 0 7.2 6.9 09/12/2005 15:40:00 6.1 0.6 7.2 4.6 5.8 0.6 7.2 4.2 312 21 304 305 6.8 0 6.9 6.7 09/12/2005 15:50:00 6.7 0.6 8 4.6 6.2 0.7 7.6 3.8 311 16 314 305 6.7 0 6.9 6.7 09/12/2005 16:00:00 7 0.5 8 5.3 6.6 0.5 8 4.9 312 17 312 305 6.6 0 6.9 6.4 09/12/2005 16:10:00 7.2 0.4 8 5.7 6.8 0.5 8 4.9 314 13 313 305 6.6 0 6.9 6.4 09/12/2005 16:20:00 7 0.4 7.6 6.1 6.7 0.5 7.6 5.3 318 5 316 305 6.6 0 6.9 6.4 09/12/2005 16:30:00 6.4 0.5 7.2 4.6 6.3 0.5 7.2 4.9 322 4 324 305 6.6 0 6.9 6.4 09/12/2005 16:40:00 5.9 0.4 6.8 4.6 5.8 0.5 6.8 4.2 326 5 321 305 6.5 0 6.7 6.4 09/12/2005 16:50:00 5.4 0.4 6.5 4.6 5.4 0.5 6.5 3.8 330 4 324 305 6.5 0 6.7 6.4 09/12/2005 17:00:00 5.1 0.4 6.1 4.2 5.1 0.4 6.1 4.2 333 3 334 305 6.5 0 6.9 6.4 09/12/2005 17:10:00 4.6 0.4 5.3 3.4 4.4 0.5 5.7 3 341 5 335 305 6.6 0 6.9 6.4 09/12/2005 17:20:00 3.1 0.6 4.6 1.5 3.1 0.5 4.9 1.9 325 15 343 305 6.6 0 6.9 6.4 09/12/2005 17:30:00 2.7 0.4 3.8 1.5 2.8 0.4 3.8 2.3 317 15 336 305 6.7 0 6.9 6.4 09/12/2005 17:40:00 2.5 0.5 3.4 1.1 2.6 0.5 3.8 1.5 321 13 327 305 6.7 0 6.9 6.4 09/12/2005 17:50:00 2.6 0.4 3.4 1.1 2.7 0.4 3.8 1.9 314 10 325 305 6.8 0 6.9 6.9 09/12/2005 18:00:00 2.9 0.4 3.8 1.5 2.8 0.4 3.8 1.9 317 9 325 305 6.8 0 6.9 6.7 09/12/2005 18:10:00 2.5 0.4 3.4 1.5 2.3 0.4 3.4 1.5 288 14 289 305 6.8 0 7.2 6.9 09/12/2005 18:20:00 2.7 0.4 3.4 1.5 2.3 0.5 3.4 1.1 282 9 293 305 6.9 0 7.2 6.9 09/12/2005 18:30:00 2.6 0.6 3.4 0.4 2.2 0.5 3.4 1.1 268 10 254 305 6.8 0 7.2 6.7 09/12/2005 18:40:00 2.8 0.4 3.8 1.5 2.1 0.4 3 1.1 266 6 265 305 6.8 0 7.2 6.9 09/12/2005 18:50:00 3.3 0.5 4.2 1.9 2.7 0.4 3.8 1.5 263 8 275 305 6.9 0 7.2 6.9 09/12/2005 19:00:00 3.2 0.5 4.6 1.9 2.8 0.5 4.2 1.5 255 9 247 305 6.9 0 7.2 6.9 09/12/2005 19:10:00 3.4 0.5 4.6 1.9 3 0.6 4.6 1.5 256 7 251 305 7 0 7.7 7.2 09/12/2005 19:20:00 3.1 0.5 4.9 1.5 2.7 0.5 3.8 1.5 254 9 256 305 7 0 7.7 6.9 09/12/2005 19:30:00 3.6 0.5 4.6 1.9 3.2 0.5 4.2 1.9 250 7 254 305 7 0 7.7 6.9 09/12/2005 19:40:00 3.9 0.5 5.3 2.3 3.5 0.5 4.6 2.3 252 8 254 305 6.9 0 7.4 6.9 09/12/2005 19:50:00 3.7 0.5 4.6 2.3 3.3 0.5 4.6 2.3 252 8 258 305 6.9 0 7.2 6.9 09/12/2005 20:00:00 3.8 0.5 4.9 2.3 3.4 0.5 4.6 1.9 242 6 247 305 6.8 0 7.2 6.7 09/12/2005 20:10:00 3.8 0.4 4.6 2.6 3.4 0.5 4.2 1.9 251 5 247 305 7 0 7.2 6.9 09/12/2005 20:20:00 2.7 0.4 3.8 1.9 2.5 0.4 3.4 1.5 234 7 236 305 7.1 0 7.4 6.9 09/12/2005 20:30:00 1.9 0.4 2.6 1.1 2.1 0.3 2.6 1.1 224 8 234 305 7.1 0 7.4 6.9 09/12/2005 20:40:00 2.3 0.3 3 1.5 2.4 0.3 3.4 1.5 219 6 225 305 6.7 0 7.4 6.7 09/12/2005 20:50:00 3.5 0.5 4.6 2.3 3.3 0.4 4.2 2.3 220 5 214 305 6.6 0 6.9 6.4 09/12/2005 21:00:00 4.3 0.4 4.9 2.6 4.1 0.5 4.9 2.6 210 5 213 305 6.6 0 6.9 6.4 09/12/2005 21:10:00 4.6 0.3 5.3 3.8 4.6 0.4 5.3 3.4 204 5 205 305 6.7 0 6.9 6.4 09/12/2005 21:20:00 4.9 0.5 6.1 3.8 4.8 0.5 6.1 3.4 203 6 201 305 6.8 0 7.2 6.4 09/12/2005 21:30:00 4.6 0.4 6.1 3.8 4.6 0.4 5.7 3 206 6 230 305 7 0 7.2 6.9 09/12/2005 21:40:00 4.6 0.4 5.7 3.4 4.6 0.4 5.7 3.4 206 6 208 305 7 0 7.2 6.9 09/12/2005 21:50:00 5.1 0.4 6.1 3.8 5.1 0.4 6.1 3.8 207 7 219 305 7 0 7.2 6.9 09/12/2005 22:00:00 5.2 0.5 6.8 3.8 5.1 0.5 6.5 3.8 205 9 212 305 6.9 0 7.2 6.9 09/12/2005 22:10:00 5.2 0.5 6.5 3.8 5.1 0.4 6.1 3.4 210 7 194 305 6.8 0 7.2 6.4 09/12/2005 22:20:00 4.9 0.5 6.5 3.8 4.8 0.6 6.1 3.4 216 6 221 305 6.6 0 6.9 6.4 09/12/2005 22:30:00 5.3 0.6 6.8 3.4 4.7 0.6 6.5 3 232 9 233 305 6.6 0 6.9 6.4 09/12/2005 22:40:00 5.3 0.5 6.8 4.2 4.5 0.5 5.7 3 242 6 250 305 6.7 0 6.9 6.4 09/12/2005 22:50:00 5.1 0.5 6.1 3.8 4.4 0.5 5.7 3 240 6 238 305 6.6 0 6.9 6.4 09/12/2005 23:00:00 5.2 0.5 6.1 3.8 4.6 0.5 5.7 3.4 235 6 233 305 6.6 0 6.7 6.4 09/12/2005 23:10:00 5 0.5 6.1 3.4 4.4 0.5 5.7 3.4 232 6 242 305 6.5 0 6.7 6.4 09/12/2005 23:20:00 4.2 0.4 5.3 3 3.8 0.4 4.9 2.6 227 6 235 305 6.5 0 6.7 6.4 09/12/2005 23:30:00 4.4 0.5 5.3 3 3.9 0.4 4.9 3 228 6 237 305 6.5 0 6.7 6.4 09/12/2005 23:40:00 4 0.4 4.9 2.6 3.7 0.4 4.6 2.6 218 7 230 305 6.5 0 6.7 6.4 09/12/2005 23:50:00 3.9 0.4 4.9 2.6 3.6 0.4 4.9 2.6 218 7 218 305 6.5 0 6.4 6.4 09/13/2005 00:00:00 4 0.4 4.9 3 4 0.3 4.6 3 216 5 219 305 6.5 0 7.2 6.4 09/13/2005 00:10:00 4.3 0.4 4.9 3.4 4.4 0.3 5.3 3.4 210 5 212 305 6.5 0 6.7 6.4 09/13/2005 00:20:00 4.9 0.5 6.8 3.8 4.9 0.6 6.5 3 205 8 202 305 6.6 0 6.9 6.4 09/13/2005 00:30:00 5.1 0.7 6.8 2.6 5 0.6 6.8 3 209 8 204 305 6.9 0 7.2 6.7 09/13/2005 00:40:00 5.6 0.9 8 3 5.6 0.8 7.6 3.4 209 10 217 305 7 0 7.2 6.9 09/13/2005 00:50:00 5.6 0.7 7.6 3 5.4 0.8 7.6 3.4 219 9 224 305 7 0 7.2 6.9 09/13/2005 01:00:00 5.4 0.8 8 3 5.2 0.8 7.2 3.4 216 10 212 305 7 0 7.2 6.9 09/13/2005 01:10:00 5.5 1 8 2.6 5.4 1 7.6 2.6 206 11 220 305 7 0 7.2 6.9 09/13/2005 01:20:00 5.2 0.8 7.2 3 5.4 0.8 7.6 3.4 200 11 223 305 6.8 0 7.2 6.7 09/13/2005 01:30:00 5.2 0.7 7.2 3.4 5.4 0.6 7.2 3.4 195 9 215 305 6.7 0 6.9 6.7 09/13/2005 01:40:00 5.8 0.8 7.6 3.4 6.3 0.8 8 3.4 189 7 184 305 6.7 0 6.9 6.4 09/13/2005 01:50:00 5.5 0.5 6.8 4.2 5.7 0.6 7.2 4.2 192 6 194 305 6.7 0 6.9 6.4 09/13/2005 02:00:00 5.5 0.6 7.2 3.8 5.5 0.6 7.2 3.4 195 7 199 305 6.6 0 6.9 6.4 09/13/2005 02:10:00 4.7 0.7 6.8 3 4.8 0.6 6.1 2.6 196 9 210 305 6.7 0 6.9 6.7 09/13/2005 02:20:00 4.7 0.7 6.1 3 4.8 0.7 6.5 3.4 195 9 213 305 6.9 0 7.2 6.9 09/13/2005 02:30:00 5 0.5 6.1 3.8 5.2 0.5 6.8 3.4 191 6 196 305 6.9 0 7.2 6.9 09/13/2005 02:40:00 5.2 0.5 6.5 3.8 5.5 0.4 6.5 3.8 190 6 195 305 7 0 7.2 6.9 09/13/2005 02:50:00 5.1 0.5 6.1 3.4 5.5 0.5 7.2 4.2 190 6 188 305 7 0 7.2 6.9 09/13/2005 03:00:00 5.2 0.4 6.5 3.8 5.3 0.5 6.5 3.8 193 6 204 305 7 0 7.2 7.2 09/13/2005 03:10:00 5 0.4 6.1 3.8 5.1 0.5 6.5 3.4 192 5 202 305 7.2 0 7.4 7.2 09/13/2005 03:20:00 4.8 0.5 6.1 3 4.8 0.4 5.7 3.4 195 5 188 305 7.2 0 7.4 7.2 09/13/2005 03:30:00 4.6 0.4 5.7 3.4 4.8 0.4 5.7 3.8 191 4 197 305 7.2 0 7.4 7.2 09/13/2005 03:40:00 4.6 0.4 5.7 3.4 4.9 0.4 6.1 3.8 189 4 193 305 7.2 0 7.4 7.2 09/13/2005 03:50:00 4.7 0.5 5.7 3.4 4.8 0.5 5.7 3.4 193 5 197 305 7.2 0 7.4 7.2 09/13/2005 04:00:00 4.8 0.5 6.1 3.8 4.7 0.5 6.1 3.4 194 5 192 305 7.2 0 7.7 7.2 09/13/2005 04:10:00 4.4 0.5 5.7 3 4.4 0.5 5.7 3 199 5 210 305 7.2 0 7.4 7.2 09/13/2005 04:20:00 4.6 0.5 5.7 3.4 4.5 0.5 5.7 3 198 5 197 305 7.3 0 7.4 7.2 09/13/2005 04:30:00 4.5 0.4 5.7 3 4.6 0.5 6.1 3.4 193 5 195 305 7.3 0 7.7 7.2 09/13/2005 04:40:00 4.6 0.5 5.3 3 4.7 0.5 6.1 3.4 193 6 200 305 7.2 0 7.4 7.2 09/13/2005 04:50:00 5 0.4 6.5 4.2 5.1 0.5 6.5 3.8 194 4 192 305 7.2 0 7.2 7.2 09/13/2005 05:00:00 6 0.4 6.8 4.9 5.9 0.5 6.8 3.8 194 4 197 305 7.2 0 7.4 7.2 09/13/2005 05:10:00 5.7 0.5 6.8 4.2 5.6 0.6 6.8 3.8 199 5 196 305 7.3 0 7.4 7.2 09/13/2005 05:20:00 5.5 0.4 6.5 4.2 5.4 0.4 6.5 3.8 196 4 207 305 7.2 0 7.4 7.2 09/13/2005 05:30:00 4.7 0.5 6.1 3.4 4.7 0.5 5.7 3.4 196 5 197 305 7.2 0 7.4 7.2 09/13/2005 05:40:00 4.8 0.4 6.1 3.8 4.8 0.5 6.1 3.4 198 5 198 305 7.3 0 7.7 7.2 09/13/2005 05:50:00 5.1 0.4 6.1 3.8 5.1 0.5 6.1 3.4 196 4 196 305 7.4 0 7.7 7.4 09/13/2005 06:00:00 5.2 0.5 6.5 3.8 5.2 0.5 6.5 3.8 195 4 200 305 7.5 0 7.9 7.4 09/13/2005 06:10:00 4.6 0.5 6.1 3.4 4.7 0.5 5.7 3.4 194 5 192 305 7.5 0 7.7 7.4 09/13/2005 06:20:00 5.4 0.4 6.5 4.2 5.4 0.5 6.5 3.8 195 5 201 305 7.4 0 7.7 7.4 09/13/2005 06:30:00 5.8 0.4 6.8 4.6 5.7 0.5 6.8 4.6 197 5 197 305 7.3 0 7.4 7.2 09/13/2005 06:40:00 5.8 0.3 6.8 4.9 5.7 0.4 6.5 4.6 199 3 194 305 7.2 0 7.4 7.2 09/13/2005 06:50:00 5.4 0.4 6.5 4.6 5.4 0.4 6.5 4.2 203 4 198 305 7 0 7.4 6.9 09/13/2005 07:00:00 5.6 0.4 6.5 4.6 5.5 0.4 6.5 4.2 201 5 202 305 7 0 7.2 6.9 09/13/2005 07:10:00 5.9 0.5 7.6 4.6 5.5 0.5 6.8 3.8 208 7 206 305 7 0 7.2 6.9 09/13/2005 07:20:00 5.4 0.6 6.8 3.4 5.1 0.7 6.5 3.4 217 7 220 305 7 0 7.2 6.9 09/13/2005 07:30:00 4.6 0.5 6.1 3.4 4.5 0.5 5.7 3 208 12 219 305 6.9 0 7.2 6.9 09/13/2005 07:40:00 4.3 0.5 5.7 3 4.4 0.6 6.1 2.6 196 6 196 305 7 0 7.2 6.9 09/13/2005 07:50:00 5.6 0.8 7.2 3 6 0.7 7.6 3.8 190 6 194 305 7 0 7.2 6.9 09/13/2005 08:00:00 5.9 0.6 7.6 4.2 6.1 0.5 7.2 4.6 194 6 200 305 7 0 7.2 6.9 09/13/2005 08:10:00 6 0.7 7.6 4.2 6.2 0.7 7.6 4.6 190 7 188 305 7 0 7.2 6.9 09/13/2005 08:20:00 7.2 0.8 8.8 4.9 7.8 0.7 9.1 6.1 186 4 185 305 7.2 0.1 7.4 7.2 09/13/2005 08:30:00 6.8 0.6 8.4 4.6 7.4 0.5 8.8 6.1 186 4 185 305 7.3 0 7.4 7.2 09/13/2005 08:40:00 7.3 0.5 8.8 5.3 7.7 0.5 9.1 6.5 188 4 190 305 7.5 0 7.7 7.4 09/13/2005 08:50:00 7.1 0.4 8.4 5.7 7.2 0.5 8.8 5.3 191 3 196 305 7.5 0 7.9 7.4 09/13/2005 09:00:00 6.4 0.4 7.2 5.3 6.5 0.4 7.6 5.3 191 3 198 305 7.5 0 7.7 7.4 09/13/2005 09:10:00 6.1 0.5 7.2 4.2 6.7 0.4 7.6 5.3 186 4 193 305 7.5 0 8.2 7.4 09/13/2005 09:20:00 6.6 0.4 7.6 5.7 6.9 0.4 8.4 5.3 188 4 184 305 7.7 0 7.9 7.7 09/13/2005 09:30:00 6.1 0.4 7.6 4.9 6.5 0.4 7.6 5.3 189 4 196 305 7.7 0 7.9 7.7 09/13/2005 09:40:00 6.5 0.5 7.6 4.6 7 0.4 8 5.7 187 4 189 305 7.8 0 7.9 7.7 09/13/2005 09:50:00 6.7 0.3 7.6 5.7 7 0.4 8 5.3 189 3 189 305 7.9 0 8.2 7.9 09/13/2005 10:00:00 6.6 0.4 7.6 5.3 6.9 0.4 7.6 5.3 188 3 187 305 8 0 8.2 7.9 09/13/2005 10:10:00 5.9 0.6 7.2 3.8 6.3 0.5 7.6 4.9 186 4 186 305 8.1 0 8.7 7.9 09/13/2005 10:20:00 5.1 0.9 6.8 2.6 6 0.6 7.2 4.6 183 5 191 305 8.3 0.1 8.9 8.2 09/13/2005 10:30:00 4.6 1 6.5 2.3 5.5 0.5 6.5 4.2 182 6 190 305 8.6 0 9.2 8.2 09/13/2005 10:40:00 5.2 0.8 6.8 2.6 5.8 0.6 7.2 4.2 183 5 188 305 8.7 0 9.2 8.4 09/13/2005 10:50:00 3.7 0.8 6.1 1.9 5.3 0.6 6.8 3.4 175 6 185 305 8.9 0 9.2 8.7 09/13/2005 11:00:00 3.8 0.8 5.3 1.9 4.4 0.5 5.3 3 160 6 159 305 8.8 0 9.2 8.7 09/13/2005 11:10:00 3.5 0.7 4.9 1.9 4.2 0.5 5.7 2.6 159 8 167 305 8.9 0 9.2 8.9 09/13/2005 11:20:00 3.3 0.8 5.3 1.1 3.7 0.6 5.3 2.3 157 8 156 305 9.1 0 9.2 8.9 09/13/2005 11:30:00 3.1 0.6 4.6 1.5 3.7 0.5 4.9 2.6 160 11 161 305 9.1 0 9.2 8.9 09/13/2005 11:40:00 3.7 0.6 5.3 1.9 3.9 0.6 5.3 2.3 146 11 142 305 9.1 0 9.2 9.2 09/13/2005 11:50:00 3.9 0.5 5.3 2.6 4.1 0.5 5.3 2.6 141 9 138 305 9.1 0 9.2 8.9 09/13/2005 12:00:00 3.3 0.6 4.9 1.9 3.6 0.5 4.9 2.3 145 12 145 305 9.1 0 9.2 8.9 09/13/2005 12:10:00 4.4 0.6 6.1 2.6 4.5 0.6 6.1 3 137 8 137 305 9.2 0 9.5 9.2 09/13/2005 12:20:00 4.6 0.7 6.5 3 4.7 0.7 6.5 3.4 143 9 142 305 9.2 0 9.5 9.2 09/13/2005 12:30:00 4.6 0.8 6.1 2.3 4.8 0.6 6.1 3.4 142 9 130 305 9.2 0 9.5 9.2 09/13/2005 12:40:00 4.9 0.8 6.8 3 5.1 0.7 7.2 3.4 140 10 134 305 9.3 0 9.5 9.2 09/13/2005 12:50:00 5 0.8 7.2 2.6 5 0.7 7.2 3.4 143 9 155 305 9.3 0 9.5 9.2 09/13/2005 13:00:00 4.4 0.8 6.5 1.9 4.6 0.7 6.8 2.6 142 11 146 305 9.3 0.1 9.7 9.2 09/13/2005 13:10:00 4.9 0.7 6.8 3 5.1 0.7 7.2 3.4 134 8 131 305 9.3 0.1 9.7 9.2 09/13/2005 13:20:00 5 0.7 6.5 3 5 0.7 6.8 3 136 9 126 305 9.3 0.1 9.7 9.2 09/13/2005 13:30:00 5.2 1 6.8 2.3 5.2 0.9 7.2 2.6 134 12 128 305 9.3 0 9.7 9.2 09/13/2005 13:40:00 3.8 0.8 5.7 1.1 3.9 0.8 6.1 1.9 128 14 137 305 9.4 0.1 9.7 9.2 09/13/2005 13:50:00 4.5 1 6.5 1.9 4.6 0.8 6.5 2.6 128 16 150 305 9.5 0.1 9.7 9.2 09/13/2005 14:00:00 5.2 0.9 7.6 3 5.3 0.9 7.6 3.4 130 15 123 305 9.3 0.1 10 9.2 09/13/2005 14:10:00 5.5 0.9 7.6 3 5.6 0.8 7.6 3.8 123 11 136 305 9.3 0 9.7 9.2 09/13/2005 14:20:00 4.8 0.9 7.2 3 4.9 1 8 2.6 122 13 112 305 9.6 0 10.2 9.5 09/13/2005 14:30:00 5.2 1 7.2 3 5.3 0.8 7.2 3 129 14 151 305 9.5 0 10 9.5 09/13/2005 14:40:00 4.5 1 7.2 1.9 4.5 1 7.2 2.3 123 12 122 305 9.7 0 10 9.5 09/13/2005 14:50:00 5.1 1.1 7.6 2.3 5.1 1.1 8 2.6 121 12 135 305 9.5 0 10 9.5 09/13/2005 15:00:00 5.6 1 8.4 3 5.6 1 8 3.4 126 13 127 305 9.5 0 10 9.2 09/13/2005 15:10:00 5.3 0.9 8 3 5.3 0.9 7.6 3 121 11 118 305 9.3 0 9.7 9.2 09/13/2005 15:20:00 5.8 0.9 7.6 3.4 5.8 0.9 8 3.4 128 11 112 305 9.1 0 9.5 9.2 09/13/2005 15:30:00 5.6 0.8 8 3.8 5.5 0.8 8 3.4 120 17 120 305 9 0 9.2 8.9 09/13/2005 15:40:00 5.9 0.9 8.4 3.4 5.9 0.9 8 3.8 116 15 92 305 8.9 0 9.2 8.9 09/13/2005 15:50:00 6.2 0.9 8.8 3.8 6.2 0.8 8 4.2 114 13 116 305 8.8 0 8.9 8.7 09/13/2005 16:00:00 5.2 1.1 8 1.9 5.4 1 7.6 2.3 113 17 105 305 8.8 0 8.9 8.7 09/13/2005 16:10:00 4.5 1.1 6.8 1.5 4.5 1.1 7.6 2.3 109 15 90 305 8.8 0.1 9.2 8.7 09/13/2005 16:20:00 5.1 1.1 8 1.9 5 1 8.4 2.3 101 14 109 305 8.7 0 8.9 8.4 09/13/2005 16:30:00 4.6 1 7.6 1.9 4.7 0.9 8 2.6 92 17 81 305 8.7 0 9.2 8.7 09/13/2005 16:40:00 4.8 1.1 8 1.5 4.8 1 9.1 2.3 96 18 110 305 8.8 0 9.2 8.7 09/13/2005 16:50:00 5.2 1.2 7.6 2.3 5.1 1.2 8.4 2.3 92 17 101 305 8.8 0 9.2 8.7 09/13/2005 17:00:00 5.2 1.1 9.5 1.9 5.3 1 8.8 2.3 87 15 61 305 8.9 0 9.2 8.9 09/13/2005 17:10:00 5.2 1.1 7.2 2.6 5.1 1 7.6 2.6 82 15 82 305 8.8 0 9.2 8.7 09/13/2005 17:20:00 5 1.3 7.6 1.5 5.1 1.3 8.8 2.3 80 17 72 305 8.8 0 9.2 8.7 09/13/2005 17:30:00 5 1.2 8.8 1.9 5 1.1 8 1.9 85 20 62 305 8.8 0 9.2 8.7 09/13/2005 17:40:00 5.4 1.1 8.4 2.6 5.3 1.1 8.4 2.6 83 16 85 305 8.9 0.1 9.5 8.9 09/13/2005 17:50:00 6.4 1 9.1 3 6.2 1 8.8 3.8 89 11 91 305 8.8 0.1 9.2 8.4 09/13/2005 18:00:00 6.6 0.9 9.1 4.2 6.5 0.9 8.4 3.8 91 10 100 305 8.6 0 9.2 8.4 09/13/2005 18:10:00 6 0.8 8.4 3.8 5.9 0.6 7.6 4.2 91 11 112 305 8.6 0 9.2 8.4 09/13/2005 18:20:00 4.5 1 7.6 2.3 4.3 1 7.6 1.9 96 14 94 305 8.4 0 8.9 8.2 09/13/2005 18:30:00 4.4 1 8 2.3 4.4 1 8 2.3 87 16 85 305 8.3 0.1 8.7 8.2 09/13/2005 18:40:00 5.1 1.1 7.2 2.3 5.1 1.1 7.6 2.3 88 16 75 305 8.2 0 8.7 7.9 09/13/2005 18:50:00 5.1 1 8.4 2.6 5 1 8 2.6 94 17 81 305 8.1 0 8.7 7.9 09/13/2005 19:00:00 4.6 1.1 8 1.9 4.7 1.1 8 2.3 95 16 91 305 8 0 8.4 7.9 09/13/2005 19:10:00 4 0.9 6.5 1.9 4 0.9 6.1 1.5 93 17 93 305 8 0 8.4 7.9 09/13/2005 19:20:00 4.4 1 8 1.5 4.4 0.9 6.8 2.3 98 15 104 305 7.9 0 8.4 7.9 09/13/2005 19:30:00 4.6 0.8 6.8 2.6 4.5 0.8 6.8 2.6 95 17 94 305 7.9 0 8.4 7.7 09/13/2005 19:40:00 4.4 0.8 6.5 2.3 4.3 0.8 6.5 2.6 93 15 95 305 7.9 0 8.4 7.7 09/13/2005 19:50:00 5.3 1.1 8.8 2.6 5.3 1 7.6 3 92 15 71 305 7.9 0 8.4 7.9 09/13/2005 20:00:00 5.3 1.1 8.4 2.6 5.3 1.1 8.4 3 94 15 99 305 7.9 0 7.9 7.7 09/13/2005 20:10:00 5.3 1.1 8.8 3.4 5.2 1.1 8.8 3.4 100 15 117 305 7.9 0 7.9 7.7 09/13/2005 20:20:00 6.8 0.8 8.8 4.2 6.7 0.8 9.1 4.2 100 11 105 305 7.9 0 7.9 7.9 09/13/2005 20:30:00 7 0.9 9.1 4.6 6.9 0.9 9.9 4.9 100 10 114 305 7.9 0 7.9 7.7 09/13/2005 20:40:00 7.1 0.8 8.8 4.9 7 0.7 8.4 5.3 102 9 96 305 7.9 0 7.9 7.7 09/13/2005 20:50:00 7.5 0.8 9.9 5.3 7.3 0.8 9.5 4.9 98 9 89 305 7.9 0 7.9 7.9 09/13/2005 21:00:00 8.1 0.8 10.3 4.9 8.1 0.8 10.7 4.9 103 9 113 305 8 0 8.2 7.9 09/13/2005 21:10:00 8.4 0.6 9.9 6.5 8.2 0.6 9.9 6.1 111 6 110 305 8 0 8.2 7.9 09/13/2005 21:20:00 8.3 0.8 10.3 6.5 8.2 0.7 10.3 6.5 114 6 103 305 8 0 8.2 7.9 09/13/2005 21:30:00 8.6 0.7 11.1 6.8 8.5 0.7 11.1 6.8 113 7 111 305 8.1 0 8.2 7.9 09/13/2005 21:40:00 8.4 0.8 10.3 6.1 8.4 0.8 10.3 6.5 117 8 114 305 8.1 0 8.2 7.9 09/13/2005 21:50:00 8.2 0.8 9.9 6.1 8 0.8 9.9 5.7 117 7 117 305 8.1 0 8.2 7.9 09/13/2005 22:00:00 8 0.7 10.3 6.1 7.8 0.7 10.3 5.7 120 7 119 305 8.1 0 8.2 7.9 09/13/2005 22:10:00 7.2 0.9 9.1 4.9 7.1 0.9 9.1 4.9 123 8 132 305 8 0 8.4 7.9 09/13/2005 22:20:00 6.7 1 9.5 4.2 6.7 1 9.5 3.8 124 9 120 305 8 0 8.4 7.9 09/13/2005 22:30:00 6.4 1.1 9.1 4.2 6.4 1 8.8 3.8 129 10 133 305 8 0 8.4 7.9 09/13/2005 22:40:00 6.6 0.8 8.8 4.6 6.6 0.8 9.1 4.2 132 9 134 305 8.1 0 8.2 7.9 09/13/2005 22:50:00 7.2 0.9 9.5 4.9 7.1 0.9 8.8 4.6 134 7 137 305 8.1 0 8.7 7.9 09/13/2005 23:00:00 8 0.5 9.5 5.7 7.9 0.5 9.1 5.7 137 4 127 305 8 0 8.2 7.9 09/13/2005 23:10:00 8.3 0.4 9.1 6.8 8.1 0.4 9.5 6.5 137 4 134 305 8.1 0 8.7 8.2 09/13/2005 23:20:00 8.1 0.6 9.1 6.5 7.9 0.5 9.1 6.1 132 5 134 305 8.2 0.1 8.9 8.2 09/13/2005 23:30:00 7.6 0.5 8.4 5.7 7.6 0.5 8.4 6.1 135 5 128 305 8.2 0.1 8.9 8.2 09/13/2005 23:40:00 7.7 1 9.9 4.9 7.5 1 9.5 4.9 135 6 141 305 8.2 0.1 8.7 8.2 09/13/2005 23:50:00 8.3 0.6 9.5 6.5 8.2 0.6 9.5 6.1 138 5 141 305 8.3 0.1 8.9 8.2 09/14/2005 00:00:00 7.8 0.6 9.1 6.1 7.7 0.6 8.8 5.7 138 5 139 305 8.2 0.1 8.7 8.2 09/14/2005 00:10:00 7.3 0.6 8.4 5.3 7.2 0.6 8.8 5.3 138 6 133 305 8.2 0.1 8.7 8.2 09/14/2005 00:20:00 6.4 0.8 8 4.2 6.3 0.8 8.4 3.8 142 7 133 305 8.1 0 8.7 7.9 09/14/2005 00:30:00 5.3 0.6 6.8 3.4 5.3 0.6 7.6 3.8 148 9 154 305 8 0 8.4 7.9 09/14/2005 00:40:00 7.3 1 9.9 4.9 7.2 0.9 9.1 4.9 148 8 144 305 8.1 0 8.7 7.9 09/14/2005 00:50:00 7.9 1 9.9 5.7 7.7 0.9 9.9 5.7 149 6 156 305 8.2 0 8.7 8.2 09/14/2005 01:00:00 7.3 0.8 9.5 4.6 7.1 0.7 9.1 5.3 150 6 155 305 8.2 0.1 8.7 8.2 09/14/2005 01:10:00 7.7 0.7 9.1 5.7 7.6 0.7 9.5 5.3 150 7 161 305 8.2 0.1 8.7 8.2 09/14/2005 01:20:00 7.3 0.5 9.1 5.3 7.2 0.5 8.8 6.1 148 6 155 305 8.2 0.1 8.7 8.2 09/14/2005 01:30:00 6.2 0.6 7.6 4.2 6.2 0.5 7.6 4.9 147 7 156 305 8.2 0 8.7 8.2 09/14/2005 01:40:00 7.4 0.5 8.4 6.1 7.3 0.5 8.4 5.7 143 4 146 305 8.2 0.1 8.7 8.2 09/14/2005 01:50:00 7.4 0.6 9.1 5.7 7.2 0.6 8.4 5.7 142 5 147 305 8.1 0 8.7 7.9 09/14/2005 02:00:00 7.8 0.6 9.1 5.7 7.6 0.6 8.8 5.3 141 4 140 305 8 0 8.7 7.9 09/14/2005 02:10:00 8.2 0.6 9.9 6.1 7.9 0.6 9.1 6.1 137 4 142 305 8 0 8.2 7.9 09/14/2005 02:20:00 8.9 0.6 10.3 6.8 8.7 0.6 9.9 6.8 136 4 137 305 8 0 8.2 7.9 09/14/2005 02:30:00 9.4 0.6 11.1 7.2 9.3 0.6 10.7 7.2 136 3 141 305 7.9 0 7.9 7.7 09/14/2005 02:40:00 8.8 0.8 10.3 6.8 8.5 0.8 9.9 6.8 136 4 130 305 7.8 0 7.9 7.7 09/14/2005 02:50:00 8.1 0.5 9.5 6.5 8 0.5 9.1 6.5 135 4 138 305 7.8 0 7.9 7.7 09/14/2005 03:00:00 8.1 0.7 9.5 6.5 8 0.7 9.5 6.1 133 5 136 305 7.9 0 7.9 7.7 09/14/2005 03:10:00 8.5 0.7 9.9 6.1 8.3 0.7 9.9 6.5 137 4 139 305 7.9 0 7.9 7.7 09/14/2005 03:20:00 7 1 8.8 4.6 6.9 1 8.8 4.6 131 8 129 305 7.9 0 8.2 7.9 09/14/2005 03:30:00 5.7 1.3 8.8 3 5.6 1.2 9.5 3 128 14 129 305 7.9 0 8.2 7.7 09/14/2005 03:40:00 7 1.3 10.7 3.4 6.9 1.3 10.3 3.8 125 13 142 305 7.9 0 7.9 7.7 09/14/2005 03:50:00 8 1.2 10.7 3.8 8 1.1 11.1 4.9 134 11 130 305 8 0 8.2 7.9 09/14/2005 04:00:00 8.1 1 11.1 4.9 8 1.1 11.1 4.6 130 11 127 305 7.9 0 7.9 7.9 09/14/2005 04:10:00 8.1 1 11.1 5.7 8.1 1.1 11.1 4.9 129 11 142 305 7.9 0 8.2 7.7 09/14/2005 04:20:00 8 1 10.3 5.7 8 1 10.7 6.1 128 9 110 305 7.9 0 7.9 7.7 09/14/2005 04:30:00 7.3 1.1 9.5 4.2 7.3 1 9.9 4.6 130 11 133 305 7.9 0 7.9 7.7 09/14/2005 04:40:00 7.2 0.9 9.1 4.9 7.1 0.9 9.1 4.6 132 10 137 305 7.9 0 7.9 7.7 09/14/2005 04:50:00 6.7 0.9 9.1 4.2 6.7 0.9 8.8 4.6 125 10 124 305 7.9 0 7.9 7.7 09/14/2005 05:00:00 5.8 1 8.8 3.4 5.7 1 8.8 3.8 126 10 124 305 7.8 0 7.9 7.7 09/14/2005 05:10:00 4.6 1.5 8 0.4 4.5 1.2 7.2 1.9 125 14 145 305 7.7 0 7.7 7.7 09/14/2005 05:20:00 4.5 1.3 8.4 1.1 4.6 1.1 7.6 2.6 132 15 154 305 7.7 0 7.9 7.7 09/14/2005 05:30:00 5.7 1.3 8.8 2.6 5.7 1.2 8.8 3 125 12 131 305 7.7 0 7.9 7.7 09/14/2005 05:40:00 7.1 1.2 9.5 3.8 7 1.2 9.5 4.2 124 11 131 305 7.7 0 7.9 7.7 09/14/2005 05:50:00 6.8 1.2 9.1 3 6.6 1.2 9.5 2.6 123 12 135 305 7.8 0 7.9 7.7 09/14/2005 06:00:00 6.1 1.5 9.9 2.3 6 1.3 9.9 3 118 16 123 305 7.7 0 7.9 7.7 09/14/2005 06:10:00 6.3 1.1 8.8 3.8 6.2 1.1 8.8 3.8 113 12 119 305 7.7 0 7.9 7.7 09/14/2005 06:20:00 4.8 1.3 8.8 2.3 4.8 1.2 8.8 2.3 108 19 101 305 7.7 0 7.9 7.7 09/14/2005 06:30:00 4.1 1 6.8 1.5 4.2 0.9 6.8 1.9 113 19 131 305 7.7 0 7.7 7.7 09/14/2005 06:40:00 3.6 1.1 6.5 1.1 3.7 1 6.8 1.1 120 23 138 305 7.7 0 7.7 7.7 09/14/2005 06:50:00 6.1 1.1 8.4 3 6 1 8.4 3.4 126 11 124 305 7.7 0 7.9 7.7 09/14/2005 07:00:00 4.6 0.9 6.8 1.9 4.6 0.9 6.8 2.6 119 18 111 305 7.6 0 7.7 7.7 09/14/2005 07:10:00 4.3 1.3 8.4 1.9 4.4 1.2 8 2.3 118 21 136 305 7.6 0 7.7 7.7 09/14/2005 07:20:00 5.4 1.2 8.4 2.6 5.4 1 8 3 124 16 108 305 7.6 0 7.7 7.7 09/14/2005 07:30:00 4.7 1.5 9.9 1.1 4.7 1.3 9.9 1.9 116 22 100 305 7.6 0 7.7 7.7 09/14/2005 07:40:00 4.5 1.5 9.1 0.7 4.5 1.3 9.1 1.5 114 21 101 305 7.7 0 7.9 7.7 09/14/2005 07:50:00 4.7 1.7 8.8 1.5 4.5 1.5 9.5 1.9 105 19 102 305 7.6 0 7.9 7.7 09/14/2005 08:00:00 4.5 1.5 8.8 1.5 4.4 1.3 8.4 1.9 103 22 117 305 7.6 0 7.7 7.7 09/14/2005 08:10:00 4.7 1.9 9.5 0.4 4.6 1.7 8.4 0.4 105 35 99 305 7.7 0 7.9 7.7 09/14/2005 08:20:00 5.9 1.2 10.7 3.4 5.8 1.1 9.5 3.8 109 17 113 305 7.9 0 7.9 7.7 09/14/2005 08:30:00 6 1.5 9.9 1.9 6 1.5 10.3 2.6 105 20 87 305 7.9 0 8.2 7.7 09/14/2005 08:40:00 4.7 1.5 8 0.7 4.7 1.3 8 1.9 86 23 43 305 7.8 0 7.9 7.7 09/14/2005 08:50:00 4.9 1.2 7.6 1.9 4.9 1.2 8 1.9 86 22 105 305 7.9 0 7.9 7.9 09/14/2005 09:00:00 5.1 1.3 8.4 1.5 5.1 1.4 9.9 1.5 90 22 127 305 8 0 8.2 7.9 09/14/2005 09:10:00 6.3 1.7 10.7 1.9 6.2 1.6 10.7 2.3 85 21 82 305 7.9 0 8.4 7.9 09/14/2005 09:20:00 6.7 1.6 11.5 3 6.5 1.5 10.3 3.4 90 22 104 305 7.9 0 8.4 7.7 09/14/2005 09:30:00 6.5 1.6 11.1 2.6 6.3 1.5 9.9 2.6 89 20 85 305 7.9 0 7.9 7.7 09/14/2005 09:40:00 6.9 1.6 12.2 3.8 6.7 1.7 11.8 3 84 22 66 305 7.9 0 7.9 7.7 09/14/2005 09:50:00 6.4 1.5 11.1 2.3 6.2 1.4 10.3 3.4 87 20 65 305 7.7 0 7.9 7.7 09/14/2005 10:00:00 6 1.5 10.3 1.1 5.9 1.5 9.5 1.9 87 27 54 305 7.8 0 7.9 7.7 09/14/2005 10:10:00 4.4 1.5 9.1 0.7 4.4 1.3 7.6 1.9 97 27 110 305 7.7 0 7.9 7.7 09/14/2005 10:20:00 5.2 1.3 8.4 1.5 5.2 1.2 8.4 2.3 83 17 93 305 7.7 0 7.9 7.7 09/14/2005 10:30:00 6.3 2 11.8 0.7 6.2 1.9 11.1 1.5 106 21 114 305 7.9 0 7.9 7.7 09/14/2005 10:40:00 6.8 1.5 11.1 2.6 6.8 1.5 10.3 3 110 21 103 305 7.9 0 7.9 7.9 09/14/2005 10:50:00 6 1.7 11.8 2.6 5.9 1.7 11.5 2.6 113 17 108 305 7.9 0 7.9 7.7 09/14/2005 11:00:00 6.3 1.7 11.1 2.3 6.2 1.7 11.8 2.6 123 18 121 305 7.9 0 7.9 7.9 09/14/2005 11:10:00 8.2 1.4 11.8 4.9 8 1.3 11.5 4.6 126 11 128 305 8 0 8.2 7.9 09/14/2005 11:20:00 6.3 1.1 9.5 3.4 6.2 1.1 9.1 3.8 130 15 128 305 8.1 0 8.4 7.9 09/14/2005 11:30:00 4.7 1.3 8.8 2.3 4.7 1.3 8.4 2.3 117 21 110 305 8.1 0 8.4 7.9 09/14/2005 11:40:00 5 1.5 9.5 1.9 4.9 1.5 10.3 2.3 121 20 149 305 8.1 0 8.4 7.9 09/14/2005 11:50:00 6.4 1.3 10.7 3 6.4 1.3 9.9 3 127 20 136 305 8 0 8.4 7.9 09/14/2005 12:00:00 7.4 1.7 11.5 3 7.3 1.7 12.2 3.4 126 15 132 305 8.1 0 8.7 7.9 09/14/2005 12:10:00 9.1 1.8 13.7 4.2 8.9 1.7 12.6 4.6 125 12 120 305 8.2 0.1 8.9 8.2 09/14/2005 12:20:00 8.4 1.7 13.3 4.6 8.2 1.7 13.3 4.9 129 13 112 305 8.3 0.1 8.9 8.2 09/14/2005 12:30:00 7.4 1.7 12.6 3.8 7.4 1.7 11.8 4.2 136 17 151 305 8.4 0.1 8.9 8.2 09/14/2005 12:40:00 6.8 1.7 11.1 1.5 6.7 1.5 10.3 2.6 126 17 120 305 8.3 0.1 8.9 8.2 09/14/2005 12:50:00 6.7 1.5 10.7 2.6 6.4 1.6 10.7 2.3 126 17 123 305 8.2 0.1 8.9 8.2 09/14/2005 13:00:00 5.2 1.7 10.3 1.5 5 1.5 9.5 1.9 128 18 134 305 8.1 0 8.7 8.2 09/14/2005 13:10:00 3.7 1.5 6.8 0.4 3.8 1.4 6.8 0.4 109 38 70 305 8.1 0 8.7 7.9 09/14/2005 13:20:00 4 1.7 8.8 0.4 3.9 1.4 8 0.7 125 29 145 305 8.1 0 8.7 7.9 09/14/2005 13:30:00 3 1.7 8 0.4 3.2 1.5 7.2 0.4 105 39 113 305 8.1 0 8.4 7.9 09/14/2005 13:40:00 3.3 1.6 8.8 0.4 3.4 1.6 9.1 0.4 115 43 138 305 8 0 8.4 7.9 09/14/2005 13:50:00 6.3 1.8 11.8 2.3 6.3 1.7 11.8 2.6 132 19 153 305 8 0 8.4 7.9 09/14/2005 14:00:00 4 2.2 11.5 0.4 4.1 2 10.3 0.7 133 32 123 305 8.1 0 8.4 7.9 09/14/2005 14:10:00 4.2 1.7 9.1 0.4 4.4 1.5 8.8 1.1 131 26 133 305 8.1 0 8.4 7.9 09/14/2005 14:20:00 5.7 1.7 11.8 0.4 5.6 1.7 11.8 1.9 134 21 121 305 8 0 8.4 7.9 09/14/2005 14:30:00 4.4 1.9 10.7 0.4 4.4 1.9 8.8 0.4 133 26 103 305 8 0 8.4 7.9 09/14/2005 14:40:00 3.4 1.9 8.4 0.4 3.7 1.9 8 0.4 117 45 156 305 8 0 8.4 7.9 09/14/2005 14:50:00 2.4 1.3 7.2 0.4 2.3 1.2 5.3 0.4 97 51 120 305 7.9 0 8.2 7.9 09/14/2005 15:00:00 5 2.2 11.8 0.4 5.3 2.1 11.5 1.5 64 28 56 305 7.9 0 7.9 7.7 09/14/2005 15:10:00 7.3 1.9 12.6 2.3 7.1 1.9 13 3.4 63 21 47 305 7.9 0 7.9 7.7 09/14/2005 15:20:00 8.3 2.7 16.8 2.6 8.2 2.9 17.9 3 64 21 71 305 7.9 0 7.9 7.7 09/14/2005 15:30:00 9.6 2.6 14.9 3.8 9.6 2.7 15.6 3 60 17 72 305 7.8 0 7.9 7.7 09/14/2005 15:40:00 10.3 2.4 16.8 4.2 10.6 2.4 17.6 4.6 59 14 56 305 7.7 0 7.9 7.7 09/14/2005 15:50:00 10.5 2.5 17.2 4.2 10.3 2.5 16.4 4.2 61 15 85 305 7.7 0 7.9 7.7 09/14/2005 16:00:00 9.8 1.8 14.1 4.6 9.8 2 14.9 4.6 64 15 43 305 7.6 0 7.7 7.4 09/14/2005 16:10:00 10.6 1.8 15.3 5.3 10.6 1.7 15.6 6.5 61 11 64 305 7.5 0 7.7 7.4 09/14/2005 16:20:00 11.1 2.3 18.3 6.5 11.2 2.3 18.3 5.7 63 12 70 305 7.5 0 7.7 7.4 09/14/2005 16:30:00 11.7 1.8 17.2 6.8 12 1.9 17.6 8 65 11 61 305 7.6 0 7.7 7.7 09/14/2005 16:40:00 12.3 1.8 18.3 8 12.5 2 19.5 5.7 66 9 62 305 7.7 0 8.2 7.7 09/14/2005 16:50:00 13.4 1.7 18.3 9.1 13.4 1.6 17.9 9.5 67 9 72 305 7.7 0 7.9 7.7 09/14/2005 17:00:00 13.8 1.5 18.3 9.5 13.7 1.7 17.9 9.5 69 7 67 305 7.7 0 8.2 7.7 09/14/2005 17:10:00 14 1.6 19.9 8 13.9 1.7 19.5 7.2 69 7 66 305 7.8 0 7.9 7.7 09/14/2005 17:20:00 13.8 1.6 18.7 10.7 13.7 1.7 19.1 9.5 69 8 47 305 7.9 0 8.2 7.7 09/14/2005 17:30:00 14.3 1.7 19.5 9.9 14.1 1.7 19.9 10.3 67 7 62 305 7.9 0 8.2 7.9 09/14/2005 17:40:00 14.6 1.4 19.5 10.7 14.4 1.5 19.9 9.1 69 7 69 305 8 0 8.4 7.9 09/14/2005 17:50:00 15.1 1.5 20.2 11.1 14.8 1.7 20.6 9.5 69 7 92 305 8.1 0 8.7 7.9 09/14/2005 18:00:00 14.9 1.7 18.7 10.3 14.7 1.8 19.5 9.9 71 7 73 305 8.1 0 8.7 7.9 09/14/2005 18:10:00 14.9 1.4 19.5 11.1 14.7 1.5 19.5 9.1 70 6 69 305 8 0 8.4 7.9 09/14/2005 18:20:00 14.8 1.7 18.7 10.7 14.7 1.7 19.9 9.9 69 8 74 305 8 0 8.4 7.9 09/14/2005 18:30:00 15 1.9 19.9 9.5 15 2.1 21 8.8 69 10 76 305 8 0 8.4 7.9 09/14/2005 18:40:00 14.4 2.2 19.9 8.4 14.5 2.4 20.2 8 67 11 49 305 7.9 0 8.2 7.9 09/14/2005 18:50:00 13.8 2.8 24 5.3 13.8 2.9 22.9 6.5 65 13 74 305 8 0 8.2 7.9 09/14/2005 19:00:00 13.1 2.6 19.5 7.6 13.1 2.9 19.9 4.9 65 15 86 305 8 0 8.2 7.9 09/14/2005 19:10:00 12.7 3.5 21.8 3.8 12.7 3.5 21 4.6 63 18 70 305 8.1 0 8.2 7.9 09/14/2005 19:20:00 12.1 3.1 20.6 3 12.3 3.1 20.6 4.6 62 17 45 305 8.2 0 8.4 8.2 09/14/2005 19:30:00 12.1 3.3 24 3.8 11.9 3.6 24 3 63 19 77 305 8.4 0 8.9 8.2 09/14/2005 19:40:00 10.5 3.5 19.9 3.4 10.4 3.6 20.2 3.8 66 23 62 305 8.5 0 8.9 8.2 09/14/2005 19:50:00 11.6 2.9 19.9 4.9 11.4 3.3 19.9 4.2 62 22 47 305 8.6 0 8.9 8.4 09/14/2005 20:00:00 12.9 3.5 22.9 4.2 12.8 3.8 23.3 3.4 62 16 58 305 8.6 0 9.2 8.4 09/14/2005 20:10:00 13 3.3 19.9 3.4 13 3.6 20.6 2.6 69 23 80 305 8.6 0 9.2 8.4 09/14/2005 20:20:00 12.8 3.2 20.2 3.8 12.8 3.3 21 3.8 65 17 77 305 8.6 0 8.9 8.4 09/14/2005 20:30:00 12.2 3.3 21 2.6 12.4 3.5 21.4 2.3 64 18 72 305 8.5 0 8.9 8.4 09/14/2005 20:40:00 12.1 3.3 21.8 5.3 12 3.5 21.8 4.9 63 20 48 305 8.6 0 8.9 8.4 09/14/2005 20:50:00 13.1 3.5 23.7 5.7 13.1 4 24.8 4.9 68 19 47 305 8.7 0 9.2 8.4 09/14/2005 21:00:00 14.2 3.3 22.1 6.1 14.1 3.6 22.6 5.7 65 16 58 305 8.7 0 9.2 8.7 09/14/2005 21:10:00 14.4 2.5 24 8.8 14.7 2.7 22.1 6.5 63 11 49 305 8.7 0 9.2 8.4 09/14/2005 21:20:00 15.3 2.8 22.6 8.8 15.1 2.9 24 8 67 11 62 305 8.6 0 9.2 8.4 09/14/2005 21:30:00 15 3.2 23.3 6.5 14.9 3.2 23.7 5.3 66 12 79 305 8.6 0 9.2 8.4 09/14/2005 21:40:00 14.5 2.4 22.1 8 14.5 2.8 22.9 6.1 65 12 55 305 8.7 0 9.2 8.4 09/14/2005 21:50:00 14.5 3.1 22.1 5.3 14.5 3.3 21.8 4.6 64 13 72 305 8.7 0 9.2 8.4 09/14/2005 22:00:00 15 2.8 24.8 8.4 15.1 2.9 24 8.4 66 14 70 305 8.7 0 9.2 8.7 09/14/2005 22:10:00 15.7 2.9 23.7 6.8 15.7 2.9 23.7 6.8 64 12 61 305 8.8 0.1 9.2 8.7 09/14/2005 22:20:00 14.8 3.3 23.3 6.8 14.7 3.3 24.4 6.1 69 15 78 305 8.8 0.1 9.5 8.7 09/14/2005 22:30:00 15.9 2.6 24 9.5 15.8 2.7 23.7 7.6 67 10 79 305 8.8 0.1 9.5 8.7 09/14/2005 22:40:00 16.5 2.2 23.3 11.1 16.2 2.3 22.6 10.7 67 9 70 305 8.8 0.1 9.2 8.7 09/14/2005 22:50:00 15.9 2.6 24.4 9.5 15.6 2.7 24.8 9.9 68 9 72 305 8.8 0.1 9.2 8.7 09/14/2005 23:00:00 15.6 2.5 23.7 8 15.6 2.6 23.3 8 67 10 51 305 8.8 0.1 9.2 8.7 09/14/2005 23:10:00 15.6 2.4 22.9 10.3 15.3 2.5 22.1 9.9 66 11 69 305 8.8 0 9.5 8.9 09/14/2005 23:20:00 16 2.8 22.6 8.4 15.9 2.8 25.2 7.6 66 12 47 305 8.9 0 9.2 8.9 09/14/2005 23:30:00 16 2.6 24.4 9.1 16 2.6 23.3 8.8 68 12 68 305 8.9 0 9.2 8.9 09/14/2005 23:40:00 15.4 3.2 27.1 7.6 15.2 3.3 26.8 7.2 68 15 62 305 8.9 0 9.2 8.9 09/14/2005 23:50:00 14.6 3.2 24.8 6.1 14.8 3.3 24.8 5.7 64 15 57 305 8.8 0 9.2 8.7 09/15/2005 00:00:00 14.2 3.3 21 5.3 14.2 3.6 23.7 4.6 61 14 81 305 8.8 0 9.2 8.9 09/15/2005 00:10:00 12.8 3.6 23.3 2.3 12.6 3.6 23.3 3.8 64 21 47 305 8.8 0 9.2 8.9 09/15/2005 00:20:00 11.2 3.2 19.5 3.4 10.9 3.3 20.6 4.6 71 23 92 305 8.8 0.1 9.2 8.9 09/15/2005 00:30:00 11.4 3.2 18.7 4.2 11.2 3.5 21.4 2.3 65 20 53 305 8.8 0 9.2 8.7 09/15/2005 00:40:00 10 2.7 16.8 3 9.8 3.1 17.9 2.6 71 26 71 305 8.7 0 9.2 8.4 09/15/2005 00:50:00 8.1 2.5 14.9 1.9 7.9 2.5 15.3 3 73 26 59 305 8.6 0 8.9 8.4 09/15/2005 01:00:00 6.7 2.3 12.6 1.1 6.5 2.2 13.3 1.5 79 27 60 305 8.4 0 8.4 8.4 09/15/2005 01:10:00 6.6 2.2 13 1.5 6.5 2.2 13 1.5 85 26 64 305 8.4 0 8.4 8.2 09/15/2005 01:20:00 5.2 2 10.3 0.4 5 1.8 10.7 1.5 82 28 45 305 8.3 0 8.7 8.2 09/15/2005 01:30:00 6.4 1.6 10.7 2.3 6.3 1.6 9.9 2.3 74 26 62 305 8.2 0.1 8.7 8.2 09/15/2005 01:40:00 5.4 1.7 11.1 1.9 5.3 1.5 10.3 2.3 94 27 117 305 8.3 0.2 8.9 8.2 09/15/2005 01:50:00 4.7 1.9 11.5 0.4 4.7 1.7 9.9 1.1 102 26 127 305 8.4 0 8.9 8.2 09/15/2005 02:00:00 4.5 1.9 11.1 0.4 4.4 1.7 10.7 0.7 110 32 122 305 8.5 0 9.2 8.4 09/15/2005 02:10:00 4.7 2.3 11.5 0.4 4.7 1.9 9.9 1.1 110 26 131 305 8.6 0 8.9 8.4 09/15/2005 02:20:00 4.2 1.5 8.8 1.5 4.3 1.3 8.4 1.9 100 29 130 305 8.4 0.1 8.9 8.2 09/15/2005 02:30:00 6.1 2.3 12.2 1.1 5.9 2.1 12.2 1.9 114 22 124 305 8.4 0 8.9 8.2 09/15/2005 02:40:00 8.2 1.7 14.5 4.9 8 1.7 14.5 4.2 124 14 130 305 8.6 0 9.2 8.4 09/15/2005 02:50:00 7.2 1.7 11.8 3.4 7 1.6 11.5 3 119 18 108 305 8.7 0 9.2 8.4 09/15/2005 03:00:00 5.6 1.9 11.5 1.9 5.7 1.9 11.1 1.9 123 22 150 305 8.6 0 9.2 8.4 09/15/2005 03:10:00 7.6 1.5 12.6 3.8 7.2 1.5 13 3.4 130 15 123 305 8.6 0 9.2 8.4 09/15/2005 03:20:00 8.8 1.6 13.3 5.3 8.6 1.5 12.6 4.6 136 12 144 305 8.8 0 9.2 8.4 09/15/2005 03:30:00 8.6 1.7 13.7 4.6 8.4 1.7 13.3 4.6 135 13 135 305 8.8 0.1 9.2 8.7 09/15/2005 03:40:00 8.4 1.9 12.6 4.6 8.3 1.7 13 4.6 134 13 123 305 8.7 0 9.2 8.7 09/15/2005 03:50:00 9.5 2.1 16.8 4.6 9.2 2 16.1 4.6 135 13 141 305 8.8 0 8.9 8.7 09/15/2005 04:00:00 9.7 2.1 14.1 4.9 9.4 2 13.7 4.6 136 12 138 305 8.7 0 8.9 8.4 09/15/2005 04:10:00 11 1.3 13.7 7.2 10.7 1.4 13.3 6.8 135 8 150 305 8.6 0 8.9 8.4 09/15/2005 04:20:00 11.3 1.2 14.1 7.2 11 1.2 14.5 7.6 134 6 135 305 8.6 0 8.7 8.4 09/15/2005 04:30:00 11.3 1 13.3 7.6 11.1 1 13.3 7.2 135 6 129 305 8.5 0 8.4 8.4 09/15/2005 04:40:00 11.3 1 14.1 8.8 11 1 13.3 8 136 5 137 305 8.4 0 8.4 8.2 09/15/2005 04:50:00 8.2 1.7 12.6 4.6 8.1 1.5 12.2 5.3 146 15 146 305 8.4 0 8.4 8.2 09/15/2005 05:00:00 11.2 1.1 13.7 8.4 11.1 1.1 13.7 7.6 133 6 132 305 8.3 0 8.4 8.2 09/15/2005 05:10:00 10.4 1.7 14.1 6.1 10.3 1.7 14.1 6.5 130 10 122 305 8.3 0 8.4 8.2 09/15/2005 05:20:00 9.4 1.5 14.1 6.1 9.2 1.5 14.1 6.1 129 14 114 305 8.2 0 8.4 8.2 09/15/2005 05:30:00 10.9 1.5 14.5 7.2 10.7 1.6 14.9 6.5 132 11 141 305 8.1 0 8.2 7.9 09/15/2005 05:40:00 10.8 1.7 15.6 7.2 10.6 1.7 15.3 6.5 130 10 127 305 8.1 0 8.2 7.9 09/15/2005 05:50:00 12.2 1.4 16.8 8.8 11.9 1.3 15.6 8 133 8 135 305 8.1 0 8.2 7.9 09/15/2005 06:00:00 11.7 1.5 14.9 8.4 11.4 1.6 14.9 6.8 132 9 133 305 8.1 0 8.7 7.7 09/15/2005 06:10:00 8.5 1.6 12.2 4.9 8.5 1.7 12.2 4.9 133 13 119 305 8.1 0 8.4 7.9 09/15/2005 06:20:00 6.3 1.3 10.7 3 6.3 1.2 9.9 3 134 14 145 305 8 0 8.4 7.9 09/15/2005 06:30:00 7.7 1.3 10.7 4.6 7.3 1.4 11.1 3.8 135 11 149 305 8.1 0 8.2 7.9 09/15/2005 06:40:00 8.1 1.1 11.1 5.3 7.9 1.1 10.3 4.9 137 9 136 305 8.2 0.1 8.7 7.9 09/15/2005 06:50:00 7.8 1.4 12.2 4.6 7.8 1.3 11.5 4.2 143 12 146 305 8.1 0 8.4 7.9 09/15/2005 07:00:00 7.7 1.1 10.7 4.2 7.6 1.2 10.7 4.6 143 12 156 305 8.2 0.1 8.7 8.2 09/15/2005 07:10:00 8.6 1.1 11.5 5.3 8.4 1.2 11.5 4.9 137 8 138 305 8.2 0.1 8.7 8.2 09/15/2005 07:20:00 9.6 1 11.8 6.8 9.3 0.9 11.5 6.5 135 6 135 305 8.1 0 8.7 7.9 09/15/2005 07:30:00 9.8 1.2 13 6.5 9.6 1.2 13 6.5 135 7 143 305 8.1 0 8.4 7.9 09/15/2005 07:40:00 9 1.2 11.8 6.5 8.7 1.2 11.5 6.5 136 9 139 305 8 0 8.4 7.9 09/15/2005 07:50:00 9.2 1.5 13 5.3 9 1.4 12.6 6.1 137 8 134 305 8 0 8.4 7.9 09/15/2005 08:00:00 9.7 1.3 13 6.1 9.6 1.3 13 5.7 135 8 141 305 8 0 8.4 7.9 09/15/2005 08:10:00 7.5 1.2 11.8 3.4 7.4 1.1 10.3 4.9 133 12 148 305 7.9 0 8.4 7.9 09/15/2005 08:20:00 7.2 1.4 11.1 3.8 7 1.3 12.6 3.8 131 14 150 305 7.9 0 8.2 7.7 09/15/2005 08:30:00 7.8 1.5 12.2 4.2 7.7 1.5 12.2 4.9 130 14 113 305 7.9 0 8.2 7.9 09/15/2005 08:40:00 8.7 1.3 13.7 5.7 8.5 1.2 12.6 5.3 134 11 146 305 7.9 0 8.2 7.9 09/15/2005 08:50:00 9.9 1.3 14.1 6.5 9.7 1.3 13.3 6.1 134 9 145 305 8 0 8.2 7.9 09/15/2005 09:00:00 10.1 1.5 13.3 4.2 10 1.5 13.3 5.3 132 9 131 305 8 0 8.2 7.9 09/15/2005 09:10:00 9.3 1.7 13.7 4.6 9.1 1.5 13.7 5.3 133 11 124 305 8 0 8.2 7.9 09/15/2005 09:20:00 10.7 1.7 14.5 5.7 10.5 1.6 13.7 5.3 133 9 127 305 8 0 8.2 7.9 09/15/2005 09:30:00 11.4 1.3 15.6 7.6 11.1 1.3 14.9 7.2 134 8 127 305 8 0 8.2 7.9 09/15/2005 09:40:00 10.7 1.5 14.5 7.2 10.5 1.5 13.7 7.6 136 9 129 305 8.2 0 8.4 7.9 09/15/2005 09:50:00 8 2.2 15.3 2.6 7.8 2.1 13.3 2.6 130 17 147 305 8.4 0 8.4 8.2 09/15/2005 10:00:00 3 1.3 6.8 0.4 3 1.3 6.8 0.4 100 43 109 305 8.2 0 8.4 8.2 09/15/2005 10:10:00 8 2.1 12.6 2.3 7.5 2 11.8 3 128 15 154 305 8.1 0 8.2 8.2 09/15/2005 10:20:00 11.5 1.2 14.9 6.8 11.3 1.2 14.5 6.8 134 7 135 305 8.4 0 8.4 8.2 09/15/2005 10:30:00 10.2 1.9 15.6 4.6 10.1 1.8 15.6 5.7 137 11 130 305 8.4 0 8.9 8.4 09/15/2005 10:40:00 7 1.9 11.1 2.6 6.9 1.7 11.5 3 130 17 113 305 8.4 0 8.7 8.2 09/15/2005 10:50:00 7.4 1.7 12.6 3.4 7.1 1.5 11.5 3 124 16 126 305 8.4 0 8.9 8.2 09/15/2005 11:00:00 9 2.1 14.5 4.2 8.7 1.9 14.5 4.2 123 16 122 305 8.5 0 8.9 8.4 09/15/2005 11:10:00 6.1 2 11.1 1.9 6 1.7 11.1 1.1 118 23 121 305 8.4 0.1 8.7 8.2 09/15/2005 11:20:00 4.1 1.7 9.1 0.4 4.1 1.7 9.5 1.1 109 43 127 305 8.3 0.1 8.7 8.2 09/15/2005 11:30:00 7.1 1.5 10.7 3.8 6.6 1.4 10.3 3 127 15 117 305 8.4 0 8.9 8.2 09/15/2005 11:40:00 9 1.5 13 5.7 8.7 1.5 12.6 4.9 133 12 134 305 8.6 0 8.9 8.4 09/15/2005 11:50:00 7.8 1.5 11.8 3.8 7.7 1.6 12.2 3.8 134 15 150 305 8.6 0 8.9 8.4 09/15/2005 12:00:00 7.1 1.5 13.3 3.8 7.2 1.7 13 3.4 138 15 152 305 8.4 0 9.2 8.4 09/15/2005 12:10:00 6.3 1.9 10.7 2.3 6.3 1.7 10.7 1.5 139 17 156 305 8.6 0 9.2 8.4 09/15/2005 12:20:00 9.7 1.3 13.3 5.7 9.4 1.2 12.6 5.7 138 9 138 305 8.7 0 9.2 8.4 09/15/2005 12:30:00 9.3 1 11.8 5.3 9 1 12.2 6.1 135 8 140 305 8.7 0 9.2 8.4 09/15/2005 12:40:00 8.4 1.1 11.1 5.3 8.1 1.1 11.1 5.3 136 8 138 305 8.6 0 9.2 8.4 09/15/2005 12:50:00 7.5 1.3 10.3 3.8 7.4 1.2 10.3 4.6 140 11 155 305 8.6 0 9.2 8.4 09/15/2005 13:00:00 8.2 1 10.7 5.3 8.2 1 10.3 5.7 135 8 136 305 8.9 0 9.2 8.7 09/15/2005 13:10:00 8.1 1.2 11.5 5.3 8.1 1.2 11.1 5.7 138 11 152 305 9.1 0 9.7 8.9 09/15/2005 13:20:00 8 1.2 12.6 4.6 8 1.1 11.5 5.3 146 11 155 305 8.9 0.1 9.5 8.9 09/15/2005 13:30:00 8.4 1.6 12.6 3.8 8.3 1.4 12.2 4.9 146 11 149 305 8.7 0 9.2 8.4 09/15/2005 13:40:00 7.5 1.2 11.1 4.9 7.4 1.1 10.7 4.9 136 12 147 305 9.1 0.3 10 8.7 09/15/2005 13:50:00 6 1.8 10.3 1.9 6 1.9 10.3 1.9 125 27 135 305 10.1 0.2 10.5 9.7 09/15/2005 14:00:00 3.5 1.5 7.6 0.4 3.6 1.3 7.2 0.4 98 47 80 305 10 0 10.5 9.7 09/15/2005 14:10:00 4.3 1.8 10.3 0.4 4.3 1.5 9.9 0.7 89 35 137 305 9.8 0 10 9.7 09/15/2005 14:20:00 2 1 4.6 0.4 2 1 4.6 0.4 105 72 112 305 9.6 0 9.7 9.5 09/15/2005 14:30:00 3.3 1.3 5.7 0.4 3.5 1.1 5.7 0.4 77 58 46 305 9.2 0 9.7 9.2 09/15/2005 14:40:00 2.8 1.5 7.6 0.4 2.9 1.4 8 0.4 113 32 150 305 9.5 0.2 10 9.2 09/15/2005 14:50:00 3.7 1.3 9.5 0.4 3.7 1.3 8.4 1.1 103 41 90 305 9.5 0.1 10 9.2 09/15/2005 15:00:00 3.7 1.3 7.2 0.4 3.8 1.3 6.8 0.7 64 22 41 305 9.3 0.2 10 8.9 09/15/2005 15:10:00 3.9 1.8 8 0.4 3.8 1.8 9.5 0.4 72 32 62 305 9.1 0 9.2 8.9 09/15/2005 15:20:00 4.1 1.3 6.8 0.4 4.2 1.3 7.2 1.1 75 30 65 305 9.2 0 9.5 8.9 09/15/2005 15:30:00 4.3 1.5 8.4 0.4 4.2 1.4 8 1.1 97 41 85 305 9.6 0 9.7 9.2 09/15/2005 15:40:00 5 2.1 11.8 0.4 5.1 1.9 12.2 1.1 125 27 132 305 9.9 0 10.2 9.7 09/15/2005 15:50:00 4.3 1.8 8.8 1.1 4.5 1.7 9.5 1.1 124 20 131 305 10.2 0 10.5 10 09/15/2005 16:00:00 3.8 1.4 7.6 0.4 3.8 1.2 7.2 0.7 79 32 87 305 10.2 0 10.2 9.7 09/15/2005 16:10:00 4.5 1.2 8 1.1 4.6 1.2 7.6 1.5 63 30 64 305 9.1 0.2 9.7 8.7 09/15/2005 16:20:00 4.9 1.5 9.1 1.1 5 1.5 9.1 1.9 50 16 47 305 8.6 0 8.9 8.4 09/15/2005 16:30:00 4.8 1.3 7.6 0.7 5.1 1.2 8 1.9 47 19 64 305 8.2 0 8.4 7.9 09/15/2005 16:40:00 5.5 1.5 9.5 1.9 5.4 1.6 11.1 1.9 49 17 44 305 8.2 0 8.4 7.9 09/15/2005 16:50:00 6.8 1.7 11.1 3 6.9 1.7 11.8 3 49 14 54 305 8.4 0 8.7 8.2 09/15/2005 17:00:00 6.6 1.6 11.1 0.7 6.6 1.7 12.2 1.5 51 18 65 305 8.6 0 8.9 8.4 09/15/2005 17:10:00 6.9 1.5 10.7 3 7.2 1.5 11.8 3.4 45 13 35 305 8.7 0 8.9 8.4 09/15/2005 17:20:00 6.6 1.4 10.7 3.4 6.8 1.3 10.7 3.4 50 13 71 305 8.6 0 8.7 8.4 09/15/2005 17:30:00 6.2 0.8 8.8 3 6.3 0.7 8 4.6 51 9 44 305 8.4 0.2 8.7 7.9 09/15/2005 17:40:00 7.4 0.4 9.1 6.1 7.3 0.5 9.1 5.7 51 4 50 305 8 0 8.2 7.9 09/15/2005 17:50:00 8.1 0.8 9.9 5.3 7.8 0.8 9.5 5.3 62 6 65 305 8.2 0 8.4 7.9 09/15/2005 18:00:00 9.9 1 12.6 7.2 9.4 1.1 12.2 7.2 69 5 69 305 8.2 0 8.4 8.2 09/15/2005 18:10:00 9.6 1.3 12.2 6.1 9 1.5 12.2 5.7 68 5 71 305 8 0.1 8.4 7.7 09/15/2005 18:20:00 8.6 0.9 11.1 6.1 7.9 1 10.7 5.3 67 7 75 305 7.7 0 7.9 7.7 09/15/2005 18:30:00 9.8 1.1 12.2 6.5 9.1 1.3 12.2 6.1 65 7 71 305 7.9 0 7.9 7.7 09/15/2005 18:40:00 10.1 1.1 13 7.6 9.5 1.2 12.6 6.8 69 7 72 305 7.7 0 7.9 7.7 09/15/2005 18:50:00 11.3 1 13.3 7.6 10.7 1.2 13.3 6.5 71 5 71 305 8 0 8.2 7.9 09/15/2005 19:00:00 11.6 1.1 13.7 8.4 11.1 1.2 14.1 8 71 5 74 305 7.9 0 8.2 7.7 09/15/2005 19:10:00 9.3 0.6 11.5 8 9 0.5 11.1 8 65 4 74 305 7.5 0 7.7 7.4 09/15/2005 19:20:00 9.9 0.7 12.2 8 9.4 0.8 12.2 6.8 66 4 68 305 7.5 0 7.7 7.4 09/15/2005 19:30:00 9.7 0.4 10.7 8.8 9.4 0.5 10.7 8 63 3 68 305 7.5 0 7.7 7.4 09/15/2005 19:40:00 9.9 0.8 11.8 8 9.7 0.8 11.5 7.6 62 4 62 305 7.5 0 7.7 7.4 09/15/2005 19:50:00 10.2 0.6 11.5 8.4 10 0.6 11.8 8 61 3 64 305 7.5 0 7.7 7.4 09/15/2005 20:00:00 10.5 0.7 12.6 8.8 10.2 0.8 12.6 8 62 4 68 305 7.5 0 8.2 7.4 09/15/2005 20:10:00 10.6 0.6 12.6 9.1 10.3 0.6 12.2 8.4 61 3 64 305 7.4 0 7.9 7.4 09/15/2005 20:20:00 10.9 0.7 13 8.8 10.5 0.8 12.6 8.8 60 4 56 305 7.4 0 7.7 7.4 09/15/2005 20:30:00 11.3 0.6 12.6 9.5 11 0.7 13 9.5 55 3 55 305 7.3 0 7.7 7.4 09/15/2005 20:40:00 11.1 0.6 13 9.1 10.7 0.7 12.6 8.8 54 4 51 305 7.3 0 7.7 7.4 09/15/2005 20:50:00 11.3 0.6 12.6 9.5 11 0.8 12.6 8.8 52 4 50 305 7.3 0 7.7 7.2 09/15/2005 21:00:00 11.6 0.6 13 9.1 11.2 0.7 13 9.1 53 4 56 305 7.4 0 7.7 7.4 09/15/2005 21:10:00 11.4 0.8 14.1 9.1 11 0.8 14.1 9.1 56 3 53 305 7.5 0 7.9 7.4 09/15/2005 21:20:00 11 0.7 13 9.1 10.6 0.7 12.6 8.8 60 4 53 305 7.4 0 7.7 7.4 09/15/2005 21:30:00 11 0.8 13.3 8.8 10.6 0.8 12.6 8.4 64 5 68 305 7.4 0 7.7 7.4 09/15/2005 21:40:00 11.4 1.1 14.5 8 10.8 1.2 14.5 8 68 5 76 305 7.4 0 7.9 7.4 09/15/2005 21:50:00 12.5 1 15.6 9.1 12.1 1.1 14.5 9.5 69 4 73 305 7.5 0 7.9 7.4 09/15/2005 22:00:00 13.5 0.8 15.6 11.1 13.1 1 15.3 9.9 70 5 75 305 7.6 0 7.7 7.7 09/15/2005 22:10:00 13.3 1 15.6 10.7 12.9 1 15.6 9.9 71 4 68 305 7.6 0 7.7 7.7 09/15/2005 22:20:00 12.3 0.8 14.1 9.5 11.8 0.8 14.1 9.1 70 4 73 305 7.5 0 7.7 7.4 09/15/2005 22:30:00 12 0.6 13.3 10.3 11.5 0.8 13.3 9.1 71 4 66 305 7.5 0 7.7 7.4 09/15/2005 22:40:00 11.7 0.8 14.5 9.9 11.3 0.9 13.3 8.8 70 5 78 305 7.5 0 7.7 7.4 09/15/2005 22:50:00 12.5 0.9 15.3 9.5 12.2 1.1 14.9 8 73 5 74 305 7.6 0 7.7 7.4 09/15/2005 23:00:00 12.1 0.7 14.5 9.9 11.9 0.8 14.5 9.5 74 4 75 305 7.6 0 7.7 7.7 09/15/2005 23:10:00 11.2 0.8 13.3 8.4 10.9 0.9 13 8.8 75 5 73 305 7.6 0 7.7 7.7 09/15/2005 23:20:00 11.2 0.7 13.3 9.1 10.8 0.8 13 8 74 4 72 305 7.6 0 7.7 7.7 09/15/2005 23:30:00 10.8 0.8 13.3 8.4 10.3 1 12.2 7.2 72 5 74 305 7.6 0 7.9 7.4 09/15/2005 23:40:00 8.6 1.1 11.5 6.5 8.2 1.1 11.1 5.7 66 6 78 305 7.3 0.1 7.7 7.2 09/15/2005 23:50:00 8.9 1 11.1 6.5 8.5 1 10.7 5.7 61 4 60 305 7.2 0 7.4 7.2 09/16/2005 00:00:00 10.9 1.5 15.3 8.4 10.5 1.5 14.1 8 68 6 81 305 7.2 0 7.7 7.2 09/16/2005 00:10:00 12.8 0.8 14.9 9.9 12.5 0.9 14.5 9.5 72 4 76 305 7.6 0 7.9 7.4 09/16/2005 00:20:00 10.5 0.9 12.6 7.6 10.2 1 13.3 7.6 67 5 69 305 7.5 0 7.7 7.2 09/16/2005 00:30:00 10.1 1 12.6 8 9.6 1 12.6 7.6 66 4 68 305 7.2 0.1 7.7 7.2 09/16/2005 00:40:00 10.2 0.9 12.6 8.4 9.8 0.9 12.6 7.6 65 5 67 305 7.1 0.1 7.7 6.9 09/16/2005 00:50:00 9.9 0.6 11.5 8.4 9.6 0.7 11.5 8 60 3 62 305 7 0 7.7 6.9 09/16/2005 01:00:00 10.4 0.6 11.8 8.4 10.1 0.7 11.5 8.4 59 3 53 305 7 0 7.4 6.9 09/16/2005 01:10:00 11.1 0.6 13 9.5 10.6 0.7 12.6 8.8 59 4 61 305 7 0 7.4 6.9 09/16/2005 01:20:00 10.6 0.6 12.2 8.8 10.1 0.7 11.8 8.4 56 4 54 305 7 0 7.4 6.9 09/16/2005 01:30:00 10.8 0.6 12.6 9.1 10.5 0.7 12.6 8.8 55 4 62 305 7 0 7.4 6.9 09/16/2005 01:40:00 11 0.7 13 8.4 10.7 0.8 12.6 8 56 4 54 305 7 0 7.7 6.9 09/16/2005 01:50:00 11 0.7 12.6 8.8 10.6 0.7 12.6 8.4 57 4 56 305 7 0 7.4 6.9 09/16/2005 02:00:00 10.7 1.1 13.3 8 10.4 1.1 13.3 7.6 64 4 64 305 7 0.1 7.7 6.9 09/16/2005 02:10:00 10.2 0.8 12.2 8.4 9.8 0.9 12.2 7.6 64 4 63 305 7.1 0.1 7.7 6.9 09/16/2005 02:20:00 9.7 0.5 11.1 8.4 9.4 0.5 11.1 8 64 3 64 305 7.1 0.1 7.7 6.9 09/16/2005 02:30:00 9.9 0.6 11.8 8.4 9.4 0.6 11.1 7.6 66 4 72 305 7 0 7.7 7.2 09/16/2005 02:40:00 10.4 0.6 12.2 8.8 9.9 0.7 11.8 8.4 68 4 71 305 7 0 7.4 7.2 09/16/2005 02:50:00 10.3 0.9 11.8 7.6 9.8 1 11.8 7.6 69 4 76 305 7.1 0 7.2 7.2 09/16/2005 03:00:00 9.9 0.6 12.2 8.8 9.6 0.6 11.5 7.6 69 4 71 305 7 0 7.2 7.2 09/16/2005 03:10:00 10.5 0.6 11.8 8.8 10.1 0.7 11.8 7.6 71 4 73 305 7.2 0 7.4 7.2 09/16/2005 03:20:00 9.7 0.8 11.5 8 9.1 0.7 11.1 7.2 70 4 71 305 7 0 7.2 6.9 09/16/2005 03:30:00 8.7 0.4 9.9 7.6 8.5 0.4 9.9 7.2 66 4 82 305 7 0 7.2 6.9 09/16/2005 03:40:00 8.9 0.5 10.3 7.6 8.7 0.5 9.9 7.2 66 4 75 305 7 0 7.2 6.9 09/16/2005 03:50:00 9.3 0.6 11.1 7.6 9 0.6 10.7 7.6 70 5 79 305 7 0 7.2 7.2 09/16/2005 04:00:00 9.2 0.5 10.7 8 9 0.5 10.7 7.6 67 4 74 305 7.1 0 7.4 7.2 09/16/2005 04:10:00 9.5 0.9 12.2 6.8 9.1 0.9 11.5 7.2 72 6 80 305 7.1 0 7.4 7.2 09/16/2005 04:20:00 10.2 0.8 12.2 8 9.9 1 12.2 7.2 72 5 70 305 7.2 0 7.7 7.2 09/16/2005 04:30:00 9.7 0.8 12.6 8 9.4 0.9 12.2 7.2 69 5 67 305 7 0 7.4 6.9 09/16/2005 04:40:00 10.6 1.1 15.6 7.6 10.3 1.1 13.7 7.6 80 7 91 305 7.2 0 7.4 7.2 09/16/2005 04:50:00 9.6 1.3 13.3 6.1 9.6 1.3 13.3 6.5 81 10 95 305 7.2 0.1 7.7 7.2 09/16/2005 05:00:00 9.4 1.4 13.7 6.1 9.5 1.4 13.3 5.7 76 10 71 305 7.2 0.1 7.7 7.2 09/16/2005 05:10:00 9.1 1.7 14.5 4.6 9.5 1.8 14.9 4.9 70 14 68 305 7.2 0.1 7.7 7.2 09/16/2005 05:20:00 7.4 1.8 11.5 1.9 7.4 1.9 12.2 2.6 76 19 66 305 7.1 0.1 7.7 7.2 09/16/2005 05:30:00 6 1.6 11.8 2.6 6 1.7 11.5 3 84 20 32 305 7 0 7.7 6.9 09/16/2005 05:40:00 5.2 1.4 9.9 1.9 5 1.2 9.5 2.3 97 23 65 305 7 0 7.4 6.9 09/16/2005 05:50:00 5.6 1.4 10.3 1.9 5.4 1.2 10.7 2.6 102 19 129 305 7 0 7.4 6.9 09/16/2005 06:00:00 5.9 1.3 9.1 3.8 5.9 1.2 8.8 3.4 103 17 80 305 7 0 7.4 6.9 09/16/2005 06:10:00 6 1.2 9.1 3.4 5.8 1.1 8.8 3.4 115 17 127 305 7 0 7.7 6.9 09/16/2005 06:20:00 5.6 0.9 8.4 3 5.5 0.8 8 3 116 15 113 305 7 0 7.7 7.2 09/16/2005 06:30:00 6.1 1.2 9.1 3 5.8 1.2 9.1 3.4 114 15 134 305 7 0 7.4 6.9 09/16/2005 06:40:00 6 1.3 9.1 2.6 5.8 1.2 8.8 3 124 12 129 305 7 0 7.7 6.9 09/16/2005 06:50:00 5.6 1.2 8.4 2.6 5.4 1.2 8 2.6 122 12 119 305 7.1 0 7.7 7.2 09/16/2005 07:00:00 5.5 1 8 3 5.5 1 8.4 3.4 121 11 130 305 7.1 0.1 7.7 7.2 09/16/2005 07:10:00 4.9 1.1 7.6 2.6 4.7 1.1 7.6 2.6 111 17 116 305 7.1 0 7.2 7.2 09/16/2005 07:20:00 4.5 1 7.2 2.6 4.3 1 7.6 1.5 105 12 114 305 7 0 7.2 6.9 09/16/2005 07:30:00 4.5 0.8 6.8 3 4.3 0.8 6.8 3 106 13 118 305 6.8 0 7.2 6.9 09/16/2005 07:40:00 4.3 0.8 6.5 2.6 4.3 0.8 6.5 2.6 118 12 108 305 6.9 0 7.2 6.9 09/16/2005 07:50:00 3.3 0.7 5.3 1.5 3.3 0.7 4.9 1.5 130 13 132 305 7 0 7.2 6.9 09/16/2005 08:00:00 3.7 0.7 4.9 1.9 3.9 0.5 5.3 2.6 145 8 148 305 7.2 0.1 7.4 7.2 09/16/2005 08:10:00 3.5 0.8 4.9 1.5 3.7 0.6 4.9 1.9 147 8 148 305 7.2 0 7.4 7.2 09/16/2005 08:20:00 4.6 0.5 5.7 3.4 4.7 0.4 5.7 3.4 135 5 141 305 7.2 0 7.4 7.2 09/16/2005 08:30:00 5 1 6.8 2.6 5.1 0.9 6.8 3 132 7 145 305 7.1 0 7.4 6.9 09/16/2005 08:40:00 6.1 0.5 7.2 4.9 6.1 0.5 7.2 4.6 137 4 142 305 7 0 7.2 6.9 09/16/2005 08:50:00 6.1 0.7 7.6 3 6.1 0.6 7.6 3.8 138 6 135 305 7 0 7.2 6.9 09/16/2005 09:00:00 5.7 0.8 7.2 3.4 5.8 0.6 7.2 4.6 149 7 144 305 7.1 0 7.4 7.2 09/16/2005 09:10:00 3.8 0.9 6.5 1.9 5.2 1 7.2 3 163 8 171 305 7.2 0 7.4 7.2 09/16/2005 09:20:00 3.3 0.6 5.3 1.9 5.5 0.7 7.2 3.8 167 4 169 305 7.3 0 7.7 7.2 09/16/2005 09:30:00 3.1 0.6 5.3 1.9 5.1 0.5 6.5 3.8 167 5 174 305 7.3 0 7.7 7.2 09/16/2005 09:40:00 3.4 0.8 5.7 1.9 4.8 0.5 6.1 3.4 164 7 153 305 7.5 0 7.7 7.4 09/16/2005 09:50:00 3.2 1 5.7 1.5 3.8 1 6.8 1.9 161 10 145 305 7.6 0 7.9 7.4 09/16/2005 10:00:00 4.3 1 7.6 2.6 5.7 0.7 7.6 3.8 163 7 150 305 7.7 0 7.9 7.7 09/16/2005 10:10:00 5 1.1 7.6 2.6 6.2 0.7 8.4 4.6 160 7 152 305 7.7 0 7.9 7.7 09/16/2005 10:20:00 4.4 0.9 6.8 2.3 6 0.7 8 4.2 163 6 158 305 7.7 0 7.9 7.7 09/16/2005 10:30:00 4 0.8 6.5 2.3 5.6 0.6 7.6 3.8 165 7 152 305 7.7 0 7.9 7.7 09/16/2005 10:40:00 4.9 1 6.8 2.3 6.4 1 8.4 4.2 174 6 177 305 7.7 0 7.9 7.7 09/16/2005 10:50:00 5.6 1 7.6 3.4 6.7 0.7 8 4.6 179 5 181 305 7.6 0 7.7 7.4 09/16/2005 11:00:00 6 0.9 7.6 3.4 7 0.5 8.4 5.3 179 4 183 305 7.5 0 7.7 7.4 09/16/2005 11:10:00 6.9 0.7 8.4 4.6 7.6 0.7 8.8 4.9 180 3 187 305 7.3 0 7.7 7.2 09/16/2005 11:20:00 6.7 0.9 8.4 4.2 6.9 0.9 8.4 4.6 185 4 189 305 7.2 0.1 7.7 6.9 09/16/2005 11:30:00 7.2 0.4 8.4 5.7 7.3 0.5 8 5.3 187 3 187 305 7 0 7.4 6.9 09/16/2005 11:40:00 7 0.5 8.4 4.6 7.3 0.6 8.4 5.3 184 3 184 305 7 0 7.2 6.9 09/16/2005 11:50:00 7.2 0.5 8.4 5.3 7.4 0.5 8.4 5.3 186 3 186 305 7 0 7.2 7.2 09/16/2005 12:00:00 7.4 0.5 8.8 5.7 7.4 0.6 8.8 5.3 187 3 186 305 7.2 0 7.4 7.2 09/16/2005 12:10:00 7.7 0.9 9.5 4.9 7.6 1 9.5 4.6 188 3 188 305 7.5 0 7.7 7.4 09/16/2005 12:20:00 8.3 0.5 9.5 5.3 8.2 0.6 9.5 6.1 188 3 184 305 7.5 0 7.7 7.4 09/16/2005 12:30:00 8.5 0.5 9.9 6.8 8.3 0.7 9.9 6.5 190 3 191 305 7.5 0 7.7 7.4 09/16/2005 12:40:00 8.9 0.6 10.3 6.8 8.8 0.7 10.3 5.7 190 3 200 305 7.6 0 7.7 7.7 09/16/2005 12:50:00 8.6 0.6 9.9 5.7 8.4 0.8 9.5 6.1 189 3 192 305 7.6 0 7.7 7.7 09/16/2005 13:00:00 8.5 0.6 9.9 6.5 8.2 0.8 9.9 5.3 193 3 196 305 7.5 0 7.7 7.4 09/16/2005 13:10:00 8.8 0.5 9.9 7.6 8.6 0.7 9.9 6.1 197 3 194 305 7.6 0 7.7 7.7 09/16/2005 13:20:00 8.4 0.7 9.9 6.1 8.1 0.9 9.9 5.7 192 4 196 305 7.5 0 7.7 7.7 09/16/2005 13:30:00 9.2 0.8 10.7 6.8 9 0.8 10.7 6.5 194 4 189 305 7.6 0 7.7 7.7 09/16/2005 13:40:00 9.8 0.7 11.1 7.2 9.5 0.9 11.1 7.2 191 3 190 305 7.6 0 7.7 7.7 09/16/2005 13:50:00 9.8 0.8 11.1 7.2 9.5 0.9 11.5 6.5 191 4 193 305 7.7 0 7.9 7.7 09/16/2005 14:00:00 10.3 0.8 12.2 7.6 10 1 12.2 6.8 190 3 188 305 7.7 0 7.9 7.7 09/16/2005 14:10:00 10.9 0.8 13 8 10.6 1 13 6.8 189 3 191 305 7.6 0 7.7 7.7 09/16/2005 14:20:00 11.4 0.8 13 8.4 11 1 13 7.6 190 3 187 305 7.5 0 7.7 7.7 09/16/2005 14:30:00 11.1 0.8 13 8.4 10.9 1 13 8.4 189 3 183 305 7.6 0 7.7 7.7 09/16/2005 14:40:00 11.1 0.7 13 9.5 10.9 0.9 12.6 8 189 3 191 305 7.5 0 7.7 7.4 09/16/2005 14:50:00 11.4 0.7 13.3 8.8 10.9 1 13.3 7.6 191 4 195 305 7.5 0 7.7 7.4 09/16/2005 15:00:00 11.3 0.7 13 8 10.8 0.9 12.6 7.6 193 4 194 305 7.3 0 7.7 7.4 09/16/2005 15:10:00 10.8 0.7 12.6 8.8 10.4 0.8 12.6 8 195 3 196 305 7.5 0 7.9 7.4 09/16/2005 15:20:00 10.8 0.7 12.2 8.4 10.3 0.9 12.2 7.2 193 4 199 305 7.5 0 7.7 7.4 09/16/2005 15:30:00 11 0.7 12.2 8.4 10.6 0.9 12.6 8 194 4 188 305 7.5 0 7.7 7.4 09/16/2005 15:40:00 10.3 0.7 12.2 8.4 9.9 0.9 12.2 7.6 195 4 195 305 7.3 0 7.7 7.4 09/16/2005 15:50:00 10 0.7 11.5 8 9.7 0.8 11.5 7.2 195 4 194 305 7.3 0 7.7 7.2 09/16/2005 16:00:00 9.9 0.7 11.5 8 9.5 0.8 11.5 6.8 196 5 194 305 7.3 0 7.4 7.2 09/16/2005 16:10:00 10.6 0.6 12.2 9.1 10.4 0.6 11.8 8.4 198 3 203 305 7.2 0 7.4 7.2 09/16/2005 16:20:00 10.1 0.5 11.5 8.8 9.8 0.6 11.5 7.6 197 3 198 305 7.3 0 7.4 7.2 09/16/2005 16:30:00 9.4 0.7 10.7 6.1 9.2 0.8 11.1 6.5 194 4 197 305 7.3 0 7.4 7.4 09/16/2005 16:40:00 9.5 0.6 11.5 7.6 9.3 0.7 11.1 7.2 196 4 199 305 7.3 0 7.4 7.2 09/16/2005 16:50:00 10.2 0.6 11.5 8.4 9.9 0.7 11.5 7.6 194 4 196 305 7.5 0 7.7 7.4 09/16/2005 17:00:00 10.5 0.6 11.8 8.4 10.2 0.7 11.8 7.6 193 3 192 305 7.3 0 7.4 7.2 09/16/2005 17:10:00 10.5 0.5 11.5 8.8 10.2 0.7 11.8 8 195 4 195 305 7.3 0 7.4 7.4 09/16/2005 17:20:00 10.5 0.6 11.8 8.8 10.2 0.8 11.8 7.2 196 3 196 305 7.3 0 7.4 7.2 09/16/2005 17:30:00 10.1 0.7 11.5 8 9.7 0.8 11.5 7.2 194 4 197 305 7.3 0 7.4 7.2 09/16/2005 17:40:00 9.7 0.9 11.8 7.2 9.5 0.9 11.8 7.2 194 4 192 305 7.3 0 7.4 7.2 09/16/2005 17:50:00 8.6 0.7 9.9 6.5 8.5 0.8 9.9 6.1 190 3 193 305 7.2 0 7.4 7.2 09/16/2005 18:00:00 9.2 0.8 11.1 7.2 8.9 1 11.5 5.7 194 4 192 305 7.3 0 7.7 7.4 09/16/2005 18:10:00 8.1 0.7 9.9 6.1 8.1 0.7 10.3 6.1 189 5 191 305 7.3 0 7.7 7.4 09/16/2005 18:20:00 8.7 0.6 10.3 7.2 8.7 0.6 10.3 7.2 192 4 193 305 7.3 0.1 7.4 7.2 09/16/2005 18:30:00 8.5 0.6 9.9 6.8 8.4 0.6 9.9 6.5 194 3 192 305 7.2 0 7.4 7.2 09/16/2005 18:40:00 7.9 0.6 9.9 6.5 7.7 0.7 9.9 6.1 195 5 203 305 7.1 0 7.4 7.2 09/16/2005 18:50:00 7.8 0.6 9.1 5.3 7.5 0.7 9.1 5.3 192 4 189 305 7.3 0 7.4 7.2 09/16/2005 19:00:00 7.7 0.5 9.1 6.1 7.6 0.6 8.8 5.3 194 3 191 305 7.3 0 7.7 7.2 09/16/2005 19:10:00 8 0.5 9.5 6.5 7.9 0.7 9.9 6.1 196 4 194 305 7.3 0 7.7 7.2 09/16/2005 19:20:00 7.3 0.7 8.8 5.3 7.2 0.8 8.8 4.6 203 4 198 305 7.2 0.1 7.7 7.2 09/16/2005 19:30:00 6.5 0.5 7.6 4.2 6.4 0.6 7.6 4.2 203 5 200 305 7.2 0.1 7.7 7.2 09/16/2005 19:40:00 5.5 0.7 6.8 3.8 5.3 0.8 6.8 3.4 203 6 197 305 7.2 0 7.7 7.2 09/16/2005 19:50:00 6.3 0.9 8.4 3.4 6 1 8 3.8 196 7 196 305 7.2 0.1 7.9 6.9 09/16/2005 20:00:00 6.8 0.6 8.4 3.8 6.8 0.5 8.4 4.9 189 4 192 305 7.4 0 7.7 7.4 09/16/2005 20:10:00 6.4 0.7 8 4.6 6.6 0.7 8.4 4.2 185 4 186 305 7.4 0 7.7 7.4 09/16/2005 20:20:00 6.4 0.7 8 3.8 7 0.6 8.8 4.9 183 3 184 305 7.3 0 7.7 7.2 09/16/2005 20:30:00 5.2 0.9 6.8 2.6 6 0.6 7.2 4.6 180 4 183 305 7.2 0.1 7.7 7.2 09/16/2005 20:40:00 4.8 0.8 6.5 2.6 5.9 0.5 7.2 4.2 179 4 181 305 7.2 0.1 7.7 7.2 09/16/2005 20:50:00 4.2 1 6.5 1.9 5.3 0.6 6.8 3.4 176 6 181 305 7.2 0 7.4 7.2 09/16/2005 21:00:00 4.5 0.9 6.5 2.3 5.4 0.5 6.5 3.4 179 5 182 305 7.2 0 7.4 7.2 09/16/2005 21:10:00 4.9 0.5 6.1 3 5.4 0.4 6.5 4.2 183 3 188 305 7.2 0 7.4 7.2 09/16/2005 21:20:00 4.4 0.7 5.3 1.9 5.1 0.5 6.1 3.8 180 4 187 305 7.2 0 7.4 7.2 09/16/2005 21:30:00 4.3 0.9 5.7 1.9 5.2 0.5 6.5 3.8 178 6 183 305 7.3 0 7.4 7.2 09/16/2005 21:40:00 3.7 0.6 4.9 1.9 4.2 0.4 5.7 3.4 158 5 154 305 7.1 0 7.4 7.2 09/16/2005 21:50:00 3.9 0.5 5.3 2.3 4 0.4 4.9 3 152 6 152 305 7 0 7.2 6.9 09/16/2005 22:00:00 3.5 0.5 4.6 1.9 3.7 0.4 4.9 2.6 152 6 153 305 7 0 7.2 6.9 09/16/2005 22:10:00 4.2 0.5 4.9 2.3 4.2 0.4 4.9 3 151 5 148 305 7 0 7.2 6.9 09/16/2005 22:20:00 4.3 0.5 5.7 3 4.5 0.4 5.3 3 156 4 156 305 7 0 7.4 7.2 09/16/2005 22:30:00 3.4 0.7 4.9 1.5 3.9 0.4 4.9 3 157 5 158 305 7 0 7.2 7.2 09/16/2005 22:40:00 3.8 0.5 4.9 1.9 4 0.3 4.9 3 155 5 149 305 7 0 7.4 7.2 09/16/2005 22:50:00 3.8 0.4 4.9 2.6 3.9 0.3 4.9 3 151 5 158 305 7 0 7.2 7.2 09/16/2005 23:00:00 3.4 0.5 4.6 1.9 3.6 0.5 4.6 2.6 145 5 147 305 7.1 0 7.7 7.2 09/16/2005 23:10:00 2.9 0.4 3.8 1.5 3.1 0.4 4.2 2.3 144 5 149 305 7 0 7.7 7.2 09/16/2005 23:20:00 2.4 0.4 3.4 1.5 2.7 0.3 3.4 1.9 133 8 137 305 7 0 7.7 6.9 09/16/2005 23:30:00 3 0.8 4.6 1.1 3.3 0.7 4.6 1.5 130 9 128 305 7 0 7.7 7.2 09/16/2005 23:40:00 3 0.6 4.6 1.1 3.3 0.5 4.9 1.9 123 9 117 305 7.1 0 7.7 7.2 09/16/2005 23:50:00 3 0.5 4.6 1.9 3.3 0.5 4.6 1.9 110 10 110 305 7.1 0 7.7 7.2 09/17/2005 00:00:00 2.9 0.5 4.2 1.9 3.1 0.5 4.2 1.9 103 8 105 305 7.1 0.1 7.7 7.2 09/17/2005 00:10:00 3.3 0.6 4.6 1.9 3.5 0.5 4.9 2.3 107 6 111 305 7 0 7.4 6.9 09/17/2005 00:20:00 3.5 0.6 4.6 1.9 3.6 0.4 4.6 2.3 103 8 117 305 7 0 7.4 6.9 09/17/2005 00:30:00 4.1 0.5 5.3 3 4.1 0.5 5.3 3 107 6 108 305 7 0 7.7 7.2 09/17/2005 00:40:00 4 0.6 5.3 2.6 4.1 0.5 5.3 2.6 110 7 108 305 7.1 0 7.7 7.2 09/17/2005 00:50:00 3.9 0.4 5.3 2.6 3.9 0.4 4.9 3 107 7 108 305 7 0 7.4 7.2 09/17/2005 01:00:00 3.9 0.4 4.9 2.6 4 0.4 4.9 3 105 7 112 305 7.1 0.1 7.7 7.2 09/17/2005 01:10:00 4.2 0.6 5.7 2.6 4.2 0.5 5.3 3 102 6 103 305 7.1 0 7.7 7.2 09/17/2005 01:20:00 4.7 0.5 5.7 3.4 4.7 0.4 5.7 3.4 101 5 102 305 7 0 7.2 7.2 09/17/2005 01:30:00 4.8 0.5 5.7 3.4 4.7 0.5 5.7 3.4 100 5 103 305 7 0 7.2 7.2 09/17/2005 01:40:00 4.7 0.4 5.7 3.4 4.7 0.4 5.7 3.8 99 5 101 305 7.1 0 7.2 7.2 09/17/2005 01:50:00 5.4 0.6 6.8 3.8 5.4 0.5 6.5 3.8 98 5 97 305 7 0 7.2 7.2 09/17/2005 02:00:00 5.7 0.5 6.8 4.6 5.6 0.5 6.8 4.6 100 5 97 305 7 0 7.4 7.2 09/17/2005 02:10:00 5.7 0.6 7.2 3.4 5.7 0.5 7.2 4.2 100 6 101 305 7.1 0 7.4 7.2 09/17/2005 02:20:00 5.1 0.7 6.8 3.4 5.1 0.6 6.5 3 100 8 101 305 7.1 0 7.4 7.2 09/17/2005 02:30:00 5.1 0.8 6.8 3 5 0.7 6.5 2.3 106 11 110 305 7.1 0 7.2 7.2 09/17/2005 02:40:00 6 0.8 8 4.2 5.9 0.8 8 3.8 112 9 131 305 7 0 7.2 7.2 09/17/2005 02:50:00 6.3 0.9 8.4 3 6.2 0.9 8 3.8 111 8 110 305 7.2 0 7.4 7.2 09/17/2005 03:00:00 5.3 1 8 2.6 5.1 1 8.4 3 95 15 102 305 7.2 0 7.4 7.2 09/17/2005 03:10:00 5.2 0.9 7.6 2.6 5.1 0.9 8 2.6 92 13 82 305 7 0 7.2 7.2 09/17/2005 03:20:00 5.3 1 7.6 3 5.2 1 8 3.4 88 17 119 305 7.1 0 7.2 7.2 09/17/2005 03:30:00 4.6 1.1 7.2 1.1 4.7 1.1 7.6 1.5 90 17 97 305 7.2 0 7.4 7.2 09/17/2005 03:40:00 4.5 1 7.6 1.9 4.7 1.1 8.4 2.3 82 20 82 305 7.3 0.1 7.7 7.2 09/17/2005 03:50:00 4.1 1.3 7.2 1.1 3.9 1.1 6.1 1.1 100 17 116 305 7.2 0 7.4 7.2 09/17/2005 04:00:00 4.8 0.9 7.2 2.3 4.9 0.9 7.2 2.6 89 19 81 305 7.2 0.1 7.7 7.2 09/17/2005 04:10:00 5.3 1 8 3 5.3 1 8.4 2.6 81 13 82 305 7.2 0.1 7.7 7.2 09/17/2005 04:20:00 5.9 1 7.6 3 5.9 0.8 7.6 3.4 75 10 54 305 7.3 0 7.7 7.2 09/17/2005 04:30:00 6.9 0.6 8.8 5.3 6.8 0.6 8.8 5.3 77 6 75 305 7.3 0 7.7 7.2 09/17/2005 04:40:00 6.6 1 9.1 3.4 6.6 0.9 8.8 3.8 78 10 69 305 7.2 0.1 7.7 7.2 09/17/2005 04:50:00 4.5 1.3 9.5 0.7 4.5 1.3 9.5 1.1 83 17 73 305 7.2 0 7.4 7.2 09/17/2005 05:00:00 4.6 1.2 8 1.9 4.6 1.2 8 1.9 82 20 58 305 7.2 0.1 7.7 7.2 09/17/2005 05:10:00 6.1 1.5 9.5 2.3 6 1.3 8.8 3.4 75 13 88 305 7.1 0 7.7 7.2 09/17/2005 05:20:00 7.4 0.7 9.5 5.3 7.2 0.7 9.5 4.9 84 6 84 305 7.1 0 7.7 7.2 09/17/2005 05:30:00 8.2 0.6 9.5 6.5 8 0.5 9.5 6.5 87 5 76 305 7.3 0 7.7 7.2 09/17/2005 05:40:00 8.5 0.9 10.7 6.1 8.1 0.9 10.7 5.7 81 7 73 305 7.3 0 7.9 7.2 09/17/2005 05:50:00 9.2 0.8 12.2 6.8 8.9 0.8 11.1 6.5 85 6 82 305 7.3 0 7.4 7.2 09/17/2005 06:00:00 9.7 0.6 11.1 8 9.4 0.6 10.7 7.2 84 5 74 305 7.2 0 7.4 7.2 09/17/2005 06:10:00 9.6 0.6 11.1 7.2 9.3 0.7 11.5 6.5 82 5 81 305 7.2 0 7.4 7.2 09/17/2005 06:20:00 9.2 0.7 11.1 6.8 8.8 0.7 10.7 6.8 79 5 81 305 7.2 0 7.4 7.2 09/17/2005 06:30:00 8.1 0.7 9.5 6.1 7.8 0.7 9.5 5.3 79 5 82 305 7.2 0 7.4 7.2 09/17/2005 06:40:00 6.7 0.6 8.4 4.6 6.6 0.6 8 4.2 92 6 84 305 7.2 0 7.4 7.2 09/17/2005 06:50:00 5.7 0.6 7.6 4.2 5.7 0.6 7.6 4.2 87 7 88 305 7.2 0 7.4 7.2 09/17/2005 07:00:00 6.4 0.4 7.6 4.9 6.3 0.5 8 4.9 85 5 82 305 7.3 0 7.4 7.2 09/17/2005 07:10:00 6.8 0.4 7.6 5.7 6.7 0.4 7.6 5.7 81 3 78 305 7.3 0 7.4 7.4 09/17/2005 07:20:00 7 0.4 8 5.7 6.9 0.4 8 5.7 75 4 75 305 7.3 0 7.4 7.2 09/17/2005 07:30:00 6.5 0.5 7.6 5.3 6.2 0.5 7.6 4.6 67 5 69 305 7 0 7.2 6.9 09/17/2005 07:40:00 5.7 0.5 6.8 4.6 5.4 0.4 6.5 4.6 63 3 62 305 6.8 0 6.9 6.7 09/17/2005 07:50:00 5.8 0.4 6.8 4.6 5.5 0.4 6.5 4.6 64 3 62 305 6.8 0 6.9 6.7 09/17/2005 08:00:00 5.4 0.4 6.8 4.6 5.1 0.4 6.5 4.2 64 4 66 305 6.8 0 7.2 6.7 09/17/2005 08:10:00 5.6 0.4 6.8 4.6 5.3 0.5 6.5 4.2 63 4 62 305 6.8 0 7.2 6.7 09/17/2005 08:20:00 6 0.4 6.8 4.9 5.7 0.4 6.8 4.6 63 4 62 305 6.8 0 7.2 6.9 09/17/2005 08:30:00 5.5 0.5 6.8 4.2 5.3 0.5 6.5 4.2 61 3 64 305 6.8 0 7.2 6.7 09/17/2005 08:40:00 6 0.5 6.8 4.2 5.6 0.5 6.8 4.2 59 3 59 305 6.8 0 7.2 6.7 09/17/2005 08:50:00 6 0.4 7.6 4.6 5.6 0.4 7.2 4.2 60 3 67 305 6.8 0 7.2 6.9 09/17/2005 09:00:00 6.8 0.5 7.6 5.3 6.4 0.5 7.6 4.9 62 5 62 305 6.9 0 7.4 6.9 09/17/2005 09:10:00 6.9 0.5 7.6 5.3 6.6 0.5 7.6 5.3 67 4 76 305 7 0 7.7 6.9 09/17/2005 09:20:00 6.9 0.4 8 5.7 6.6 0.4 7.6 5.7 67 4 65 305 7.2 0 7.7 7.2 09/17/2005 09:30:00 7 0.4 8 5.7 6.7 0.4 7.6 5.3 68 3 66 305 7.2 0 7.7 7.2 09/17/2005 09:40:00 6.4 0.5 7.6 5.3 6.1 0.4 7.2 4.9 65 5 69 305 7.2 0.1 7.7 7.2 09/17/2005 09:50:00 6.2 0.4 7.2 5.3 6 0.4 7.2 4.9 65 3 59 305 7 0 7.7 7.2 09/17/2005 10:00:00 6.4 0.5 8 4.9 6.1 0.5 7.2 4.6 67 5 67 305 7.1 0.1 7.7 7.2 09/17/2005 10:10:00 8.4 1 10.3 6.1 8.1 1 9.9 5.3 85 9 86 305 7.4 0.1 7.9 7.2 09/17/2005 10:20:00 8.1 0.6 9.9 6.1 7.8 0.6 9.5 6.1 91 5 93 305 7.6 0 7.9 7.7 09/17/2005 10:30:00 7.2 0.8 8.8 4.9 7 0.7 8.4 5.3 90 5 90 305 7.5 0 7.7 7.7 09/17/2005 10:40:00 7 0.6 8 5.3 6.7 0.6 8 4.6 85 4 87 305 7.8 0 7.9 7.7 09/17/2005 10:50:00 6.9 0.6 8.4 5.3 6.6 0.6 8.4 4.9 85 5 88 305 7.9 0 7.9 7.7 09/17/2005 11:00:00 7.3 0.6 8.8 4.9 7.1 0.6 8.8 4.6 84 5 81 305 7.7 0 7.9 7.7 09/17/2005 11:10:00 7.4 0.6 9.1 5.3 7.2 0.6 8.8 5.3 79 6 78 305 7.6 0 7.7 7.7 09/17/2005 11:20:00 6.8 0.5 8.4 5.3 6.6 0.5 8.4 5.3 79 5 85 305 7.6 0 7.9 7.7 09/17/2005 11:30:00 7.7 0.6 9.1 5.7 7.4 0.6 8.4 5.7 86 5 77 305 7.7 0 7.9 7.7 09/17/2005 11:40:00 7.5 0.6 8.8 5.7 7.2 0.6 8.8 5.7 86 5 90 305 7.8 0 7.9 7.7 09/17/2005 11:50:00 7.8 0.7 9.1 5.7 7.5 0.7 9.1 5.7 87 5 91 305 7.9 0 7.9 7.7 09/17/2005 12:00:00 7.7 0.5 8.8 6.1 7.5 0.5 8.4 5.3 90 5 87 305 7.9 0 7.9 7.9 09/17/2005 12:10:00 7.3 0.6 8.8 5.7 7.1 0.6 8.4 5.3 91 5 81 305 8 0 8.2 7.9 09/17/2005 12:20:00 7.3 0.6 8.8 5.3 7 0.6 8.4 5.3 85 5 85 305 8 0 8.2 7.9 09/17/2005 12:30:00 8 0.7 9.5 6.1 7.8 0.8 9.5 6.1 85 6 89 305 8.3 0 8.4 8.2 09/17/2005 12:40:00 8.5 0.7 10.7 6.5 8.2 0.7 10.3 6.5 83 6 83 305 8.4 0 8.7 8.2 09/17/2005 12:50:00 8.7 0.7 10.3 6.5 8.3 0.7 9.9 6.1 84 6 82 305 8.3 0.1 8.9 8.2 09/17/2005 13:00:00 8.7 0.8 11.1 6.5 8.4 0.8 10.3 6.1 85 6 82 305 8.4 0 8.7 8.2 09/17/2005 13:10:00 8.4 0.8 9.9 6.1 8.1 0.8 9.5 6.1 89 6 78 305 8.5 0 8.9 8.2 09/17/2005 13:20:00 9 0.7 10.7 6.8 8.6 0.7 9.9 6.8 90 6 96 305 8.6 0 8.9 8.4 09/17/2005 13:30:00 8.5 0.7 10.3 6.5 8.1 0.7 9.5 5.7 87 6 85 305 8.4 0 8.7 8.2 09/17/2005 13:40:00 8.3 1 10.7 5.7 8 0.8 10.3 5.7 83 6 88 305 8.3 0 8.7 8.2 09/17/2005 13:50:00 8.2 0.7 10.3 6.5 7.8 0.7 9.9 6.5 84 7 87 305 8.2 0 8.4 8.2 09/17/2005 14:00:00 8.1 0.8 10.3 5.7 7.9 0.8 9.9 6.1 79 7 67 305 8.2 0 8.4 7.9 09/17/2005 14:10:00 8.4 0.7 10.3 5.7 8.1 0.7 9.9 5.7 79 5 86 305 8.2 0.1 8.7 8.2 09/17/2005 14:20:00 8.1 0.5 9.5 6.1 7.8 0.6 9.5 5.7 77 5 81 305 8.4 0 8.7 8.2 09/17/2005 14:30:00 8 0.7 9.9 6.1 7.6 0.7 9.5 5.7 76 6 80 305 8.7 0.1 8.9 8.4 09/17/2005 14:40:00 7.7 0.5 8.4 6.5 7.3 0.5 8.4 5.3 68 4 71 305 8.4 0.2 8.9 7.9 09/17/2005 14:50:00 7 0.6 8.8 5.3 6.7 0.6 8.4 4.9 67 6 71 305 8.1 0 8.2 7.9 09/17/2005 15:00:00 6.2 0.4 7.6 5.3 6.1 0.5 7.2 4.6 63 5 76 305 8.2 0 8.2 8.2 09/17/2005 15:10:00 5.9 0.4 6.8 4.9 5.7 0.5 6.8 4.2 52 5 56 305 8 0 8.2 7.9 09/17/2005 15:20:00 6.7 0.6 8 4.9 6.5 0.7 8.4 4.9 50 4 52 305 7.6 0.2 8.2 7.4 09/17/2005 15:30:00 6.6 0.5 7.6 4.9 6.4 0.6 7.6 4.9 50 5 53 305 7.4 0 7.7 7.2 09/17/2005 15:40:00 6.6 0.4 7.6 5.3 6.3 0.4 7.2 5.3 40 4 39 305 7.3 0 7.7 7.4 09/17/2005 15:50:00 7.2 0.3 8 6.5 7 0.3 8 5.3 40 3 38 305 7.3 0 7.7 7.2 09/17/2005 16:00:00 7.1 0.4 8.4 5.7 6.8 0.5 8.4 5.3 45 4 45 305 7.2 0 7.4 7.2 09/17/2005 16:10:00 7.5 0.4 8.4 6.5 7.2 0.6 8.4 5.3 50 3 51 305 7.3 0 7.7 7.2 09/17/2005 16:20:00 6.6 0.5 7.6 5.3 6.4 0.5 8 4.9 54 3 50 305 7.3 0 7.7 7.2 09/17/2005 16:30:00 6.2 0.4 7.2 4.9 6 0.4 6.8 4.6 55 3 57 305 7.2 0 7.4 7.2 09/17/2005 16:40:00 5.8 0.4 6.8 4.2 5.7 0.5 6.8 4.6 56 3 53 305 7 0 7.4 6.9 09/17/2005 16:50:00 5.6 0.6 7.2 4.2 5.5 0.6 7.2 4.2 57 5 53 305 7 0 7.2 6.9 09/17/2005 17:00:00 5.9 0.4 7.2 4.9 5.7 0.4 6.8 4.6 55 4 62 305 7.2 0 7.4 7.2 09/17/2005 17:10:00 5.8 0.4 6.8 4.6 5.6 0.5 6.8 4.2 54 5 54 305 7.2 0 7.4 7.2 09/17/2005 17:20:00 5.7 0.5 6.8 4.6 5.5 0.6 6.8 4.2 53 4 51 305 7.3 0 7.4 7.2 09/17/2005 17:30:00 6.5 0.7 8.4 4.9 6.4 0.7 8 4.6 53 3 54 305 7.2 0 7.4 7.2 09/17/2005 17:40:00 5.9 0.5 6.8 4.6 5.8 0.5 6.8 4.2 56 4 54 305 7.1 0 7.4 7.2 09/17/2005 17:50:00 6.3 0.5 7.6 5.3 6.1 0.5 7.2 4.9 53 3 59 305 7 0 7.2 6.9 09/17/2005 18:00:00 6 0.4 7.2 4.6 5.9 0.4 7.2 4.6 51 4 48 305 7 0 7.2 6.9 09/17/2005 18:10:00 5.8 0.4 6.8 4.6 5.6 0.4 6.5 4.6 52 3 48 305 7 0 7.2 6.9 09/17/2005 18:20:00 6.5 0.5 7.6 5.3 6.3 0.6 7.6 4.6 51 3 49 305 7 0 7.2 6.9 09/17/2005 18:30:00 6.5 0.3 7.6 5.7 6.3 0.4 7.2 4.9 47 3 49 305 7 0 7.2 6.9 09/17/2005 18:40:00 6.3 0.3 7.2 5.7 6.1 0.3 6.8 5.3 38 3 42 305 7 0 7.4 6.9 09/17/2005 18:50:00 6.9 0.4 8 5.7 6.6 0.4 7.6 5.7 38 3 44 305 7 0 7.2 6.9 09/17/2005 19:00:00 7 0.3 8 6.1 6.8 0.4 7.6 5.7 34 2 33 305 7 0 7.4 6.9 09/17/2005 19:10:00 7 0.4 8 6.1 6.7 0.4 7.6 5.7 31 3 28 305 6.9 0 7.2 6.9 09/17/2005 19:20:00 7 0.4 8 6.1 6.8 0.4 7.6 5.7 33 3 38 305 7 0 7.4 6.9 09/17/2005 19:30:00 6.8 0.4 7.6 5.7 6.6 0.4 7.6 5.7 32 3 32 305 6.9 0 7.2 6.9 09/17/2005 19:40:00 6.3 0.4 7.2 5.3 6.2 0.3 7.2 5.3 35 2 36 305 6.8 0 6.9 6.9 09/17/2005 19:50:00 6.1 0.3 7.2 5.3 6 0.3 6.8 5.3 32 3 35 305 6.8 0 6.9 6.9 09/17/2005 20:00:00 6.5 0.4 7.6 5.7 6.4 0.4 7.6 5.3 34 4 32 305 6.8 0 6.9 6.9 09/17/2005 20:10:00 6.5 0.5 7.6 5.7 6.3 0.5 7.6 5.3 37 3 42 305 6.8 0 7.2 6.7 09/17/2005 20:20:00 6.2 0.3 6.8 5.3 6 0.4 6.8 4.9 35 3 40 305 6.8 0 7.2 6.7 09/17/2005 20:30:00 6.7 0.5 8 5.3 6.6 0.6 8 4.9 31 3 33 305 6.8 0 6.9 6.7 09/17/2005 20:40:00 7.3 0.4 8.4 6.1 7.1 0.4 8.4 5.7 27 3 30 305 6.7 0 7.2 6.7 09/17/2005 20:50:00 7.6 0.5 8.8 6.1 7.4 0.5 8.4 6.1 29 3 27 305 6.7 0 6.9 6.7 09/17/2005 21:00:00 7.7 0.4 8.8 6.5 7.4 0.5 8.4 5.7 32 3 32 305 6.7 0 6.9 6.7 09/17/2005 21:10:00 7.8 0.4 8.8 6.8 7.5 0.4 8.4 6.5 32 3 32 305 6.7 0 7.2 6.7 09/17/2005 21:20:00 7.3 0.4 8.4 6.5 7 0.5 8.4 6.1 31 3 35 305 6.6 0 6.9 6.4 09/17/2005 21:30:00 7.5 0.4 8.8 6.5 7.2 0.4 8.4 6.1 30 3 30 305 6.6 0 6.9 6.4 09/17/2005 21:40:00 7.5 0.5 8.8 6.5 7.2 0.5 8.4 5.7 29 3 33 305 6.6 0 7.2 6.4 09/17/2005 21:50:00 7.6 0.4 8.8 6.5 7.3 0.4 8.4 6.1 27 3 27 305 6.7 0.1 7.2 6.4 09/17/2005 22:00:00 7.9 0.4 8.8 6.8 7.7 0.4 8.8 6.5 29 3 29 305 6.6 0.1 7.2 6.4 09/17/2005 22:10:00 7.8 0.4 8.8 6.8 7.5 0.4 8.4 6.1 29 3 30 305 6.5 0 7.2 6.4 09/17/2005 22:20:00 7.6 0.4 8.8 6.5 7.4 0.4 8.4 6.1 27 3 33 305 6.6 0.1 7.2 6.4 09/17/2005 22:30:00 7.6 0.4 8.4 6.5 7.3 0.4 8.4 5.7 29 3 30 305 6.6 0.1 7.2 6.4 09/17/2005 22:40:00 8 0.4 9.1 6.8 7.6 0.4 8.8 6.1 31 2 31 305 6.7 0.1 7.2 6.4 09/17/2005 22:50:00 7.6 0.5 8.4 6.5 7.2 0.5 8.4 5.7 28 3 30 305 6.7 0.1 7.2 6.4 09/17/2005 23:00:00 7.5 0.3 8.4 6.8 7.2 0.4 8 6.1 27 2 28 305 6.6 0.1 7.2 6.4 09/17/2005 23:10:00 7.4 0.3 8.4 6.5 7 0.3 8 5.7 26 3 28 305 6.7 0.1 7.2 6.4 09/17/2005 23:20:00 7.7 0.4 8.8 6.8 7.4 0.5 8.4 6.1 27 2 31 305 6.7 0.1 7.2 6.7 09/17/2005 23:30:00 7.6 0.3 8.4 6.8 7.4 0.3 8.4 6.5 30 3 36 305 6.7 0 7.2 6.7 09/17/2005 23:40:00 7.5 0.4 8.4 6.5 7.3 0.4 8.4 6.5 30 3 29 305 6.7 0 7.2 6.7 09/17/2005 23:50:00 7.8 0.3 8.8 7.2 7.5 0.4 8.4 6.5 30 2 31 305 6.7 0 7.2 6.7 09/18/2005 00:00:00 7.5 0.3 8.4 6.5 7.2 0.4 8.4 6.1 33 2 34 305 6.7 0 7.2 6.7 09/18/2005 00:10:00 6.9 0.3 7.6 6.5 6.6 0.3 7.6 5.7 33 2 34 305 6.7 0 7.2 6.7 09/18/2005 00:20:00 6.8 0.3 7.2 6.1 6.7 0.4 7.6 6.1 34 2 34 305 6.8 0 7.2 6.7 09/18/2005 00:30:00 6.7 0.3 7.6 5.7 6.5 0.3 7.2 5.7 32 2 20 305 6.8 0 6.9 6.9 09/18/2005 00:40:00 6.5 0.2 7.2 6.1 6.3 0.3 6.8 5.7 29 3 29 305 6.8 0 7.4 6.9 09/18/2005 00:50:00 6.5 0.3 7.2 6.1 6.4 0.3 7.2 5.7 23 2 24 305 6.8 0 7.2 6.9 09/18/2005 01:00:00 7.1 0.4 8 5.7 7 0.4 8 5.7 23 3 23 305 7 0 7.4 6.9 09/18/2005 01:10:00 7.1 0.3 7.6 6.1 7 0.3 8 6.1 26 2 24 305 7 0 7.4 6.9 09/18/2005 01:20:00 7.2 0.4 8 6.1 7.1 0.3 7.6 6.1 28 3 28 305 7 0 7.4 6.9 09/18/2005 01:30:00 7.3 0.4 8.4 6.1 7.1 0.4 8 6.1 30 2 29 305 7 0 7.2 6.9 09/18/2005 01:40:00 7.8 0.3 8.4 6.8 7.5 0.4 8.4 6.5 31 2 29 305 7 0 7.4 6.9 09/18/2005 01:50:00 7.7 0.3 8.4 6.8 7.5 0.3 8.4 6.5 32 2 29 305 7 0 7.2 6.9 09/18/2005 02:00:00 7.2 0.3 8 6.5 7 0.4 7.6 6.1 35 2 33 305 7 0 7.4 6.9 09/18/2005 02:10:00 6.6 0.3 7.6 5.7 6.4 0.3 7.2 5.3 33 3 35 305 6.9 0 7.4 6.9 09/18/2005 02:20:00 6.3 0.3 7.2 5.7 6.2 0.3 6.8 5.3 32 2 24 305 6.9 0 7.4 6.9 09/18/2005 02:30:00 5.9 0.3 6.5 5.3 5.7 0.3 6.5 4.9 36 3 33 305 6.8 0 7.4 6.7 09/18/2005 02:40:00 5.1 0.3 6.1 4.6 5 0.4 5.7 3.8 40 3 40 305 6.7 0 7.2 6.7 09/18/2005 02:50:00 5.1 0.4 6.1 4.2 4.8 0.4 5.7 3.8 36 4 32 305 6.7 0.1 7.2 6.7 09/18/2005 03:00:00 5.4 0.4 6.5 4.6 5.3 0.4 6.5 4.2 36 4 37 305 6.7 0.1 7.2 6.7 09/18/2005 03:10:00 5.9 0.3 6.5 4.9 5.7 0.3 6.5 4.9 32 2 34 305 6.8 0 7.2 6.7 09/18/2005 03:20:00 6.5 0.4 7.2 5.3 6.2 0.4 7.6 4.9 31 3 32 305 6.7 0.1 7.2 6.7 09/18/2005 03:30:00 7.1 0.3 8 6.1 6.8 0.4 7.6 5.7 28 2 25 305 6.7 0.1 7.2 6.7 09/18/2005 03:40:00 6.9 0.3 7.6 6.1 6.7 0.3 7.2 5.7 22 3 26 305 6.7 0.2 7.2 6.7 09/18/2005 03:50:00 6.4 0.4 7.2 5.7 6.3 0.4 7.2 5.3 20 3 18 305 6.7 0.2 7.2 6.7 09/18/2005 04:00:00 6.1 0.3 6.8 5.3 6 0.3 6.8 5.3 21 2 22 305 6.7 0.1 7.2 6.7 09/18/2005 04:10:00 6.2 0.3 6.8 5.3 6 0.3 6.8 5.3 24 3 27 305 6.7 0.1 7.2 6.7 09/18/2005 04:20:00 6.2 0.3 7.2 5.3 6 0.3 7.2 4.9 29 3 27 305 6.7 0.1 7.2 6.7 09/18/2005 04:30:00 6.4 0.3 7.2 5.7 6.2 0.3 6.8 5.3 23 3 24 305 6.8 0 7.2 6.7 09/18/2005 04:40:00 6.3 0.3 6.8 5.3 6.1 0.3 6.8 5.3 21 2 17 305 6.7 0 7.2 6.7 09/18/2005 04:50:00 6.2 0.4 7.2 4.9 6 0.4 6.8 4.9 18 2 15 305 6.7 0 6.9 6.7 09/18/2005 05:00:00 6.5 0.3 7.2 5.7 6.4 0.3 7.2 5.7 14 3 18 305 6.7 0.1 7.2 6.7 09/18/2005 05:10:00 6.4 0.3 7.6 5.3 6.3 0.3 7.2 5.3 15 2 11 305 6.7 0 7.2 6.4 09/18/2005 05:20:00 6.7 0.3 7.2 5.7 6.5 0.3 7.2 5.7 15 2 17 305 6.7 0 7.4 6.7 09/18/2005 05:30:00 6.8 0.3 7.6 6.1 6.6 0.3 7.2 5.7 14 2 13 305 6.7 0 7.2 6.7 09/18/2005 05:40:00 6.5 0.4 7.2 5.7 6.3 0.4 7.2 4.9 16 2 13 305 6.8 0 7.4 6.7 09/18/2005 05:50:00 6.3 0.3 7.2 5.3 6.1 0.4 6.8 5.3 18 3 15 305 6.8 0 6.9 6.7 09/18/2005 06:00:00 6.5 0.3 7.2 5.7 6.3 0.3 7.2 5.3 19 3 17 305 6.8 0 7.4 6.7 09/18/2005 06:10:00 6.6 0.4 7.6 5.3 6.4 0.4 7.2 5.3 22 3 21 305 6.7 0 7.4 6.7 09/18/2005 06:20:00 6.4 0.3 6.8 5.7 6.2 0.3 6.8 5.3 23 3 30 305 6.7 0.1 7.2 6.7 09/18/2005 06:30:00 6.3 0.3 6.8 5.3 6.1 0.3 6.8 5.3 18 3 19 305 6.6 0 6.9 6.4 09/18/2005 06:40:00 6.8 0.4 8 6.1 6.6 0.4 7.6 5.7 16 3 18 305 6.6 0 7.2 6.4 09/18/2005 06:50:00 6.4 0.4 7.6 5.7 6.3 0.4 7.2 5.3 12 3 16 305 6.6 0 7.2 6.4 09/18/2005 07:00:00 6 0.4 7.2 5.3 6 0.3 7.2 5.3 2 3 357 305 6.5 0 7.2 6.4 09/18/2005 07:10:00 7.2 0.5 8.4 5.7 7.2 0.5 8.4 5.3 5 3 6 305 6.6 0.1 7.2 6.4 09/18/2005 07:20:00 7 0.5 8.4 5.7 7 0.5 8.4 5.7 8 3 9 305 6.6 0 7.2 6.4 09/18/2005 07:30:00 6.5 0.4 7.2 5.3 6.4 0.4 7.2 5.3 7 4 7 305 6.5 0 6.7 6.4 09/18/2005 07:40:00 6.5 0.4 7.6 5.7 6.5 0.4 7.6 5.7 10 3 10 305 6.5 0 6.7 6.4 09/18/2005 07:50:00 6.5 0.6 8.4 5.3 6.4 0.6 8.4 4.9 10 4 12 305 6.5 0 6.7 6.4 09/18/2005 08:00:00 7.6 0.6 8.8 5.3 7.6 0.6 8.8 5.7 11 5 16 305 6.5 0 6.7 6.4 09/18/2005 08:10:00 7.4 0.6 8.8 5.7 7.5 0.7 8.8 5.7 10 4 11 305 6.4 0 6.4 6.1 09/18/2005 08:20:00 7 0.5 8 5.7 7 0.5 8.4 5.7 10 4 8 305 6.4 0 6.4 6.1 09/18/2005 08:30:00 7 0.5 8.4 6.1 7.1 0.5 8.4 5.7 5 4 3 305 6.5 0 6.9 6.1 09/18/2005 08:40:00 7 0.6 9.1 5.7 7.2 0.6 9.1 5.7 9 4 10 305 6.5 0 6.4 6.4 09/18/2005 08:50:00 6.7 0.4 8 5.3 6.7 0.4 8 5.7 0 5 6 305 6.5 0 7.2 6.4 09/18/2005 09:00:00 7.1 0.6 8.4 5.7 7.2 0.7 8.8 5.7 356 3 356 305 6.5 0 7.2 6.1 09/18/2005 09:10:00 7.9 0.6 9.5 6.5 8 0.6 9.5 6.1 359 4 0 305 6.3 0 6.4 6.1 09/18/2005 09:20:00 7.3 0.5 8.8 6.1 7.4 0.6 8.8 5.7 4 4 7 305 6.3 0 6.4 6.1 09/18/2005 09:30:00 7.6 0.5 8.8 6.1 7.5 0.6 9.1 5.7 5 4 6 305 6.4 0 6.4 6.1 09/18/2005 09:40:00 8.1 0.4 9.1 6.8 8 0.5 9.1 6.5 4 3 1 305 6.5 0 6.9 6.4 09/18/2005 09:50:00 7.6 0.5 9.1 6.1 7.6 0.5 8.8 6.1 5 3 6 305 6.5 0 6.7 6.4 09/18/2005 10:00:00 7.8 0.5 9.1 6.5 7.8 0.5 9.1 6.5 6 3 7 305 6.5 0 7.2 6.4 09/18/2005 10:10:00 7.9 0.5 9.1 6.5 7.9 0.6 9.5 6.1 6 3 8 305 6.6 0.1 7.2 6.4 09/18/2005 10:20:00 7.3 0.5 8.4 5.7 7.4 0.5 8.4 6.1 8 3 7 305 6.6 0 7.2 6.4 09/18/2005 10:30:00 7 0.6 8.4 5.3 7 0.6 8 5.7 8 3 11 305 6.6 0 6.7 6.4 09/18/2005 10:40:00 6.9 0.4 8 5.7 6.8 0.5 8 5.7 5 3 2 305 6.7 0.1 7.2 6.7 09/18/2005 10:50:00 7.1 0.6 8.4 5.3 7.1 0.7 8.8 5.7 2 4 5 305 6.7 0 6.9 6.7 09/18/2005 11:00:00 7.2 0.5 8.8 6.1 7.2 0.6 8.8 5.7 6 4 10 305 6.8 0 7.4 6.7 09/18/2005 11:10:00 7.5 0.6 9.1 6.1 7.7 0.6 9.1 6.5 8 3 8 305 6.8 0 7.4 6.7 09/18/2005 11:20:00 6.9 0.4 8 6.1 6.9 0.4 8 6.1 5 3 1 305 6.7 0 7.2 6.7 09/18/2005 11:30:00 6.4 0.4 7.6 5.3 6.4 0.5 8 4.9 6 5 11 305 6.8 0 7.4 6.7 09/18/2005 11:40:00 6.6 0.6 8 4.9 6.7 0.6 8 5.3 9 3 9 305 6.8 0 7.4 6.9 09/18/2005 11:50:00 6.1 0.8 7.6 4.2 6.2 0.8 8 4.6 6 5 15 305 6.8 0 7.4 6.9 09/18/2005 12:00:00 6.5 0.7 8 4.9 6.5 0.7 8 4.6 6 3 6 305 7 0 7.4 6.9 09/18/2005 12:10:00 7.5 0.6 9.1 6.1 7.5 0.6 9.1 6.1 3 3 0 305 7 0 7.4 6.9 09/18/2005 12:20:00 7 0.5 8.4 5.3 7.1 0.6 8.4 5.3 1 3 1 305 7.1 0 7.7 7.2 09/18/2005 12:30:00 7.2 0.4 8.4 6.1 7.3 0.4 8.4 6.5 1 3 0 305 7.1 0.1 7.7 7.2 09/18/2005 12:40:00 7.2 0.5 8.8 6.1 7.3 0.5 8.8 6.1 0 3 358 305 7 0 7.7 6.9 09/18/2005 12:50:00 7 0.4 8 5.7 7 0.5 8.4 5.7 0 3 0 305 7 0 7.7 6.9 09/18/2005 13:00:00 6.9 0.5 8 5.7 6.9 0.5 8 5.7 1 3 1 305 7 0 7.7 6.9 09/18/2005 13:10:00 6.4 0.6 8 5.3 6.5 0.6 8.4 5.3 1 3 3 305 7 0 7.7 6.9 09/18/2005 13:20:00 7.1 0.5 8 5.3 7.1 0.6 8.4 5.3 2 3 2 305 7.1 0.1 7.7 6.9 09/18/2005 13:30:00 6.9 0.4 8 6.1 6.9 0.5 8.4 5.3 3 3 1 305 7.1 0.1 7.7 6.9 09/18/2005 13:40:00 7.1 0.5 8 6.1 7.1 0.6 8.4 5.7 5 3 10 305 7.1 0 7.7 7.2 09/18/2005 13:50:00 6.6 0.6 8.4 5.3 6.5 0.7 8 5.3 8 3 9 305 7.2 0 7.4 7.2 09/18/2005 14:00:00 7.1 0.4 8 6.1 7 0.4 8 5.7 8 3 7 305 7.3 0 7.7 6.9 09/18/2005 14:10:00 6.8 0.4 7.6 5.7 6.8 0.4 7.6 5.3 9 3 9 305 7.3 0 7.7 7.2 09/18/2005 14:20:00 6.5 0.4 7.6 5.3 6.5 0.4 7.6 5.3 7 3 6 305 7.3 0 7.4 7.2 09/18/2005 14:30:00 6.2 0.4 7.2 4.6 6.2 0.4 7.2 4.9 7 3 7 305 7.2 0 7.4 7.2 09/18/2005 14:40:00 5.5 0.5 6.5 4.6 5.5 0.5 6.8 4.2 7 3 10 305 7.2 0 7.4 7.2 09/18/2005 14:50:00 4.8 0.4 6.1 3.8 4.8 0.4 6.1 3.8 6 4 8 305 7.1 0 7.4 7.2 09/18/2005 15:00:00 5.3 0.5 6.5 3.8 5.3 0.5 6.5 3.8 8 4 13 305 7 0 7.4 7.2 09/18/2005 15:10:00 5.5 0.3 6.1 3.8 5.4 0.4 6.5 4.2 9 3 5 305 7.1 0 7.4 7.2 09/18/2005 15:20:00 5.6 0.4 6.5 4.6 5.5 0.4 6.5 4.2 8 3 7 305 7.2 0 7.4 7.2 09/18/2005 15:30:00 5.4 0.4 6.1 4.6 5.3 0.4 6.1 4.2 10 3 10 305 7.2 0 7.4 7.2 09/18/2005 15:40:00 5.1 0.4 6.1 4.2 5 0.4 6.1 4.2 13 3 14 305 7.2 0 7.7 7.2 09/18/2005 15:50:00 4.8 0.3 5.7 4.2 4.8 0.3 5.3 3.8 14 3 17 305 7.3 0 7.4 7.2 09/18/2005 16:00:00 4.7 0.4 5.7 3.8 4.7 0.4 5.3 3.8 13 3 21 305 7.3 0.1 7.7 7.2 09/18/2005 16:10:00 3.8 0.4 4.9 2.6 3.7 0.4 4.6 2.6 10 4 15 305 7.2 0.1 7.7 7.2 09/18/2005 16:20:00 3.8 0.3 4.6 3.4 3.8 0.3 4.6 3 8 3 2 305 7.2 0.1 7.7 7.2 09/18/2005 16:30:00 4.1 0.4 5.3 2.6 4.1 0.4 5.3 3 10 5 19 305 7.3 0.1 7.7 7.2 09/18/2005 16:40:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3 14 3 15 305 7.5 0 7.9 7.4 09/18/2005 16:50:00 4.2 0.4 4.9 3.4 4.1 0.4 5.3 3 17 4 14 305 7.5 0 7.9 7.4 09/18/2005 17:00:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3.4 26 5 21 305 7.5 0 7.9 7.4 09/18/2005 17:10:00 4.9 0.4 6.1 3.8 4.9 0.5 6.1 3.8 19 6 9 305 7.4 0 7.7 7.2 09/18/2005 17:20:00 4.8 0.4 5.7 3.8 4.8 0.4 5.7 3.8 9 3 12 305 7.3 0 7.7 7.2 09/18/2005 17:30:00 4.9 0.4 6.1 3.4 4.9 0.4 6.1 3.8 10 4 11 305 7.3 0 7.7 7.2 09/18/2005 17:40:00 5.2 0.4 6.1 4.2 5.2 0.4 6.1 4.2 10 3 10 305 7.2 0 7.7 7.2 09/18/2005 17:50:00 5.4 0.3 6.1 4.6 5.4 0.3 6.1 4.6 10 2 11 305 7.2 0 7.7 7.2 09/18/2005 18:00:00 5.1 0.3 5.7 4.6 5 0.3 5.7 4.2 10 2 8 305 7.2 0.1 7.9 7.2 09/18/2005 18:10:00 5 0.2 5.7 4.2 4.9 0.3 5.7 3.8 8 2 7 305 7.2 0.1 7.9 7.2 09/18/2005 18:20:00 4.8 0.4 5.7 3.8 4.7 0.4 5.7 3.8 7 2 10 305 7.1 0 7.2 7.2 09/18/2005 18:30:00 4.4 0.3 5.3 3.8 4.4 0.3 5.3 3.4 5 3 4 305 7 0 7.2 7.2 09/18/2005 18:40:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.8 7 2 7 305 7 0 7.2 6.9 09/18/2005 18:50:00 4.6 0.3 5.3 3.8 4.5 0.3 5.3 3.8 8 3 9 305 7 0 7.2 7.2 09/18/2005 19:00:00 4.9 0.4 5.7 3.8 4.9 0.4 5.7 3.8 6 3 0 305 7 0 7.4 6.9 09/18/2005 19:10:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.8 6 2 3 305 6.9 0 7.2 6.9 09/18/2005 19:20:00 4.7 0.3 5.7 3.8 4.6 0.4 5.7 3.8 11 5 10 305 6.9 0 7.2 6.9 09/18/2005 19:30:00 4 0.4 4.9 3 4 0.4 4.9 3 18 3 21 305 6.8 0 7.2 6.9 09/18/2005 19:40:00 4.4 0.5 5.3 3 4.2 0.5 5.3 3 17 4 17 305 6.8 0 7.2 6.9 09/18/2005 19:50:00 4.9 0.3 5.7 3.8 4.8 0.3 5.3 4.2 12 3 13 305 6.9 0 7.2 6.9 09/18/2005 20:00:00 4.3 0.3 4.9 3.4 4.3 0.3 4.9 3.4 8 3 8 305 6.9 0 7.4 6.9 09/18/2005 20:10:00 3.6 0.3 4.6 3 3.5 0.3 4.6 2.6 6 3 5 305 6.9 0 7.4 6.9 09/18/2005 20:20:00 3.2 0.3 3.8 2.3 3.1 0.3 3.8 2.3 13 2 10 305 6.8 0 7.4 6.9 09/18/2005 20:30:00 2.2 0.4 3 1.5 2.3 0.3 3 1.1 6 4 11 305 6.9 0 7.4 6.9 09/18/2005 20:40:00 1.8 0.4 3 0.7 1.8 0.3 2.6 0.7 7 5 3 305 6.8 0 7.4 6.9 09/18/2005 20:50:00 3.4 0.3 3.8 2.3 3.3 0.3 3.8 2.3 13 3 11 305 6.9 0 7.4 6.9 09/18/2005 21:00:00 3.5 0.3 4.2 2.6 3.4 0.3 3.8 2.6 8 2 14 305 6.8 0 7.4 6.9 09/18/2005 21:10:00 2.5 0.4 3.4 1.5 2.4 0.3 3 1.5 11 2 9 305 6.8 0 7.4 6.7 09/18/2005 21:20:00 1.5 0.4 2.3 0.7 1.6 0.3 2.3 1.1 16 2 17 305 6.8 0.1 7.4 6.7 09/18/2005 21:30:00 0.9 0.3 1.9 0.4 1.4 0.2 1.9 1.1 22 2 20 305 6.8 0.1 7.4 6.7 09/18/2005 21:40:00 1.3 0.3 2.3 0.4 1.4 0.3 1.9 0.7 10 12 19 305 6.8 0 7.4 6.7 09/18/2005 21:50:00 1.7 0.2 2.3 1.1 1.5 0.2 2.3 0.7 334 9 337 305 6.8 0 7.4 6.7 09/18/2005 22:00:00 2 0.2 2.6 1.5 1.9 0.2 2.3 1.5 339 5 332 305 6.7 0 7.4 6.7 09/18/2005 22:10:00 2.2 0.3 3 1.5 1.9 0.3 2.6 1.1 346 3 347 305 6.7 0 7.2 6.7 09/18/2005 22:20:00 2.5 0.3 3.4 1.9 2.3 0.3 3 1.5 345 2 344 305 6.7 0 7.2 6.7 09/18/2005 22:30:00 2.7 0.3 3.4 1.9 2.5 0.2 3 1.9 341 2 345 305 6.8 0 6.9 6.7 09/18/2005 22:40:00 2.3 0.2 3 1.5 2.1 0.3 2.6 1.5 334 6 333 305 6.8 0 7.2 6.9 09/18/2005 22:50:00 2.2 0.3 3 1.5 1.8 0.4 2.6 0.7 317 5 311 305 6.8 0 6.9 6.7 09/18/2005 23:00:00 2.9 0.3 3.8 2.3 2.4 0.3 3 1.5 312 7 317 305 6.8 0 6.9 6.9 09/18/2005 23:10:00 3 0.3 3.8 2.3 2.5 0.3 3.4 1.5 312 12 317 305 6.8 0 6.9 6.9 09/18/2005 23:20:00 3.2 0.3 3.8 2.3 2.6 0.3 3.4 1.9 311 17 309 305 6.8 0 6.9 6.7 09/18/2005 23:30:00 2.7 0.4 3.4 1.9 2.3 0.3 3 1.5 315 20 311 305 6.8 0 6.9 6.7 09/18/2005 23:40:00 2.5 0.4 3.4 1.5 2.1 0.4 3 1.1 312 11 313 305 6.7 0 6.9 6.7 09/18/2005 23:50:00 2.7 0.4 3.8 1.9 2.3 0.3 3 1.5 312 12 315 305 6.7 0 6.9 6.7 09/19/2005 00:00:00 3.4 0.3 4.2 2.3 2.9 0.3 3.8 2.3 315 22 306 305 6.8 0 7.2 6.7 09/19/2005 00:10:00 3.6 0.4 4.6 2.3 3.1 0.4 4.2 2.3 314 6 305 305 6.8 0 6.9 6.7 09/19/2005 00:20:00 4 1.2 7.2 2.3 3.9 1.3 7.2 1.9 337 22 359 305 6.8 0 6.9 6.4 09/19/2005 00:30:00 6.3 0.8 7.6 3.8 6.2 0.8 7.6 3.8 12 6 17 305 6.4 0 6.7 6.1 09/19/2005 00:40:00 5.7 0.7 7.2 4.2 5.6 0.7 7.2 4.2 25 5 18 305 6.4 0 6.4 6.1 09/19/2005 00:50:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.8 22 7 15 305 6.5 0 6.9 6.1 09/19/2005 01:00:00 5.2 0.4 6.5 4.6 5.2 0.4 6.5 4.2 2 5 10 305 6.7 0 6.9 6.4 09/19/2005 01:10:00 5.3 0.5 6.8 4.2 5.4 0.4 6.8 4.6 359 5 354 305 6.7 0 6.9 6.7 09/19/2005 01:20:00 6 0.4 6.8 5.3 6 0.4 6.8 4.9 358 3 355 305 6.7 0 6.9 6.4 09/19/2005 01:30:00 6.2 0.4 7.2 5.3 6.2 0.4 6.8 5.3 359 3 0 305 6.7 0 6.9 6.4 09/19/2005 01:40:00 5.9 0.4 6.5 4.6 6 0.4 6.8 4.6 3 3 359 305 6.7 0 6.9 6.7 09/19/2005 01:50:00 5.7 0.6 6.8 4.2 5.7 0.6 6.8 4.2 6 4 1 305 6.7 0 6.9 6.4 09/19/2005 02:00:00 6.2 0.5 7.2 4.9 6.2 0.5 7.2 4.9 9 3 1 305 6.7 0 6.9 6.4 09/19/2005 02:10:00 6.7 0.4 7.6 5.3 6.7 0.4 7.6 5.3 9 3 4 305 6.6 0 6.9 6.4 09/19/2005 02:20:00 6.5 0.3 7.2 5.7 6.5 0.4 7.6 5.3 12 3 10 305 6.5 0 6.7 6.4 09/19/2005 02:30:00 6.9 0.4 8 5.7 7.1 0.5 8 6.1 12 3 11 305 6.5 0 6.9 6.4 09/19/2005 02:40:00 6.7 0.4 8 5.3 6.7 0.4 7.6 5.7 10 3 16 305 6.5 0 6.7 6.4 09/19/2005 02:50:00 7.6 0.5 8.8 6.1 7.7 0.5 9.1 6.1 11 3 13 305 6.4 0 6.4 6.1 09/19/2005 03:00:00 7.4 0.4 8.4 6.1 7.4 0.5 8.4 6.1 12 3 8 305 6.3 0 6.4 6.1 09/19/2005 03:10:00 6.4 0.4 7.6 5.3 6.4 0.5 7.6 4.9 18 4 12 305 6.3 0 6.4 6.1 09/19/2005 03:20:00 6.5 0.6 7.6 5.3 6.5 0.6 8 4.9 18 5 22 305 6.2 0 6.4 6.1 09/19/2005 03:30:00 6.3 0.4 7.6 4.9 6.4 0.5 7.6 4.9 14 3 10 305 6.2 0 6.4 5.9 09/19/2005 03:40:00 6.2 0.5 7.2 4.9 6.2 0.5 7.2 4.9 21 3 18 305 6.1 0 6.1 5.9 09/19/2005 03:50:00 6.8 0.6 7.6 4.9 6.8 0.7 8 4.9 19 4 20 305 6 0 6.1 5.9 09/19/2005 04:00:00 6.1 0.6 7.6 4.6 6.2 0.6 7.6 4.9 19 4 13 305 6 0 6.1 5.9 09/19/2005 04:10:00 5.8 0.5 6.8 4.2 5.9 0.5 6.8 4.6 20 3 18 305 6 0 5.9 5.9 09/19/2005 04:20:00 5.4 0.8 6.8 3.8 5.5 0.8 6.8 3.8 22 4 22 305 5.9 0 5.9 5.6 09/19/2005 04:30:00 5.4 0.5 6.5 4.2 5.5 0.5 6.5 3.8 21 4 21 305 5.8 0 5.9 5.6 09/19/2005 04:40:00 5.2 0.5 6.5 4.2 5.3 0.5 6.5 4.6 24 4 19 305 5.8 0 5.9 5.6 09/19/2005 04:50:00 5 0.5 6.5 3.8 5.1 0.5 6.5 3.8 23 5 14 305 5.8 0 5.9 5.6 09/19/2005 05:00:00 5.1 0.5 6.1 3.8 5.2 0.5 6.1 3.8 25 5 18 305 5.7 0 5.9 5.6 09/19/2005 05:10:00 4.7 0.4 5.7 3.8 4.8 0.4 5.7 3.4 25 5 23 305 5.6 0 5.9 5.6 09/19/2005 05:20:00 4.4 0.4 5.7 3.4 4.5 0.4 5.7 3.4 26 6 18 305 5.6 0 5.6 5.4 09/19/2005 05:30:00 4.5 0.5 5.7 3.4 4.6 0.5 6.1 3.4 24 5 21 305 5.6 0 5.9 5.6 09/19/2005 05:40:00 4.4 0.5 5.7 3.4 4.5 0.5 5.7 3.4 18 5 17 305 5.6 0 5.9 5.4 09/19/2005 05:50:00 5.3 0.4 6.1 4.2 5.4 0.4 6.5 4.6 16 3 14 305 5.6 0 5.9 5.6 09/19/2005 06:00:00 5 0.3 5.7 4.2 5.1 0.3 5.7 3.8 25 4 13 305 5.7 0 5.9 5.6 09/19/2005 06:10:00 4.9 0.4 5.7 4.2 5 0.4 6.1 4.2 27 4 31 305 5.8 0 5.9 5.6 09/19/2005 06:20:00 5 0.5 6.1 3.8 5.1 0.5 6.1 3.8 30 3 27 305 5.8 0 5.9 5.6 09/19/2005 06:30:00 5.3 0.4 6.1 4.6 5.3 0.4 6.1 4.2 30 3 26 305 5.8 0 5.9 5.6 09/19/2005 06:40:00 4.6 0.3 5.3 3.8 4.8 0.3 5.3 3.8 33 4 34 305 5.7 0 5.9 5.6 09/19/2005 06:50:00 4.4 0.4 5.3 3.4 4.6 0.4 5.3 3.8 34 3 36 305 5.7 0 5.9 5.6 09/19/2005 07:00:00 4.4 0.3 4.9 3.8 4.6 0.3 5.3 3.8 30 3 35 305 5.7 0 5.9 5.6 09/19/2005 07:10:00 4.3 0.3 4.9 3.8 4.5 0.3 5.3 3.8 36 5 32 305 5.7 0 5.9 5.6 09/19/2005 07:20:00 4.3 0.3 5.3 3.8 4.5 0.3 5.3 3.8 35 6 32 305 5.6 0 5.9 5.4 09/19/2005 07:30:00 4.2 0.4 4.9 3.4 4.4 0.4 5.3 3.4 34 5 31 305 5.6 0 5.6 5.4 09/19/2005 07:40:00 4 0.2 4.6 3.4 4.2 0.2 4.9 3.4 48 5 46 305 5.6 0 5.9 5.4 09/19/2005 07:50:00 3.5 0.3 4.2 2.6 3.6 0.4 4.6 2.6 46 5 53 305 5.6 0 5.6 5.4 09/19/2005 08:00:00 3.6 0.2 4.2 3 3.8 0.3 4.2 3 49 4 43 305 5.6 0 5.6 5.4 09/19/2005 08:10:00 3.3 0.3 4.2 2.3 3.4 0.3 4.2 2.6 59 4 52 305 5.5 0 5.6 5.4 09/19/2005 08:20:00 3.6 0.4 4.2 2.6 3.8 0.4 4.6 2.6 44 8 42 305 5.5 0 5.6 5.4 09/19/2005 08:30:00 3.6 0.2 4.2 3 3.8 0.3 4.6 3 40 3 40 305 5.6 0 5.6 5.4 09/19/2005 08:40:00 3.6 0.2 4.2 3 3.9 0.3 4.6 3 49 6 45 305 5.6 0 5.9 5.6 09/19/2005 08:50:00 3.4 0.3 4.2 2.6 3.6 0.3 4.6 2.6 57 4 61 305 5.6 0 5.9 5.6 09/19/2005 09:00:00 3 0.3 4.2 2.3 3.2 0.3 4.2 2.6 54 6 51 305 5.7 0 5.9 5.6 09/19/2005 09:10:00 3.3 0.4 3.8 1.9 3.6 0.4 4.2 2.3 47 5 45 305 5.7 0 5.9 5.6 09/19/2005 09:20:00 4.1 0.4 5.3 3.4 4.4 0.4 5.7 3.4 41 4 37 305 5.6 0 5.6 5.4 09/19/2005 09:30:00 4.5 0.4 5.3 3.4 4.7 0.4 5.7 3.8 43 4 36 305 5.5 0 5.6 5.4 09/19/2005 09:40:00 3.9 0.3 4.6 3 4.1 0.3 4.6 3 52 5 50 305 5.4 0 5.6 5.4 09/19/2005 09:50:00 3.3 0.2 3.8 2.6 3.5 0.3 4.2 2.6 60 4 53 305 5.5 0 5.6 5.4 09/19/2005 10:00:00 3.3 0.3 3.8 2.3 3.5 0.3 4.2 2.6 62 3 57 305 5.5 0 5.6 5.4 09/19/2005 10:10:00 3 0.4 4.2 2.3 3.2 0.4 4.2 2.3 62 6 52 305 5.8 0 5.9 5.6 09/19/2005 10:20:00 3.8 0.5 4.9 2.3 3.9 0.5 5.3 2.6 63 9 50 305 6 0 6.1 5.9 09/19/2005 10:30:00 4.2 0.3 4.6 3.4 4.4 0.3 4.9 3 54 4 50 305 6 0 6.1 5.9 09/19/2005 10:40:00 3.9 0.4 4.6 2.6 4.2 0.4 4.9 3 59 3 53 305 6 0 6.1 5.9 09/19/2005 10:50:00 3.7 0.3 4.6 2.6 3.9 0.4 4.6 2.6 61 3 58 305 6 0 6.1 5.9 09/19/2005 11:00:00 3.6 0.3 4.2 2.6 3.7 0.3 4.6 2.6 65 4 64 305 6.1 0 6.1 5.9 09/19/2005 11:10:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 63 4 53 305 6.1 0 6.4 5.9 09/19/2005 11:20:00 2.8 0.5 3.8 1.5 3 0.5 3.8 1.5 70 7 72 305 6.2 0 6.4 5.9 09/19/2005 11:30:00 1.8 0.7 3.4 0.4 2.3 0.5 3.4 1.1 106 13 99 305 6.7 0.1 7.4 6.4 09/19/2005 11:40:00 1.2 0.5 2.6 0.4 1.9 0.3 3 1.1 125 10 116 305 7 0.1 7.7 6.9 09/19/2005 11:50:00 1.4 0.4 2.6 0.4 2.1 0.3 2.6 1.1 138 17 139 305 7.3 0 7.9 7.2 09/19/2005 12:00:00 2.1 0.7 3.8 0.7 2.5 0.6 3.8 1.1 108 14 94 305 7.5 0 7.9 7.4 09/19/2005 12:10:00 3.2 0.4 4.2 2.3 3.3 0.4 4.6 2.3 102 7 108 305 7.3 0.1 7.7 7.2 09/19/2005 12:20:00 3.4 0.4 4.6 1.9 3.5 0.4 4.6 2.6 104 8 94 305 7.3 0.1 7.7 7.2 09/19/2005 12:30:00 3.4 0.4 4.2 2.6 3.7 0.4 4.6 2.6 118 6 124 305 7.2 0.1 7.7 7.2 09/19/2005 12:40:00 3.4 0.5 4.6 1.9 3.6 0.5 4.6 2.3 114 8 115 305 7.3 0 7.7 7.2 09/19/2005 12:50:00 3.2 0.5 4.2 1.9 3.4 0.5 4.6 1.9 118 9 104 305 7.3 0 7.4 7.4 09/19/2005 13:00:00 3.4 0.6 4.9 1.9 3.6 0.6 4.9 2.3 119 8 124 305 7.4 0 7.7 6.9 09/19/2005 13:10:00 3.1 0.6 4.6 1.5 3.5 0.5 4.9 2.3 129 11 118 305 7.3 0 7.4 7.2 09/19/2005 13:20:00 3.2 0.4 4.2 1.9 3.5 0.4 4.6 2.3 134 10 140 305 7.5 0 7.7 7.4 09/19/2005 13:30:00 3.4 0.4 4.2 1.9 3.7 0.4 4.6 2.6 133 6 141 305 7.4 0 7.7 7.4 09/19/2005 13:40:00 2.6 0.6 4.2 0.7 3 0.5 4.6 1.5 134 7 134 305 7.5 0 7.7 7.4 09/19/2005 13:50:00 2.2 0.5 3.4 0.7 2.6 0.4 3.4 1.5 133 9 129 305 7.8 0 7.9 7.7 09/19/2005 14:00:00 1.5 0.7 3.4 0.4 2 0.5 3.8 0.7 130 10 138 305 8 0 8.4 7.7 09/19/2005 14:10:00 0.7 0.5 1.9 0.4 1.2 0.7 3 0.4 132 22 142 305 8.2 0 8.9 8.2 09/19/2005 14:20:00 1.4 1 3.4 0.4 2 1 3.8 0.4 142 38 127 305 8.4 0.1 9.2 8.2 09/19/2005 14:30:00 0.6 0.4 1.9 0.4 1.2 0.6 2.6 0.4 199 29 179 305 8.1 0 8.4 7.9 09/19/2005 14:40:00 0.7 0.5 2.3 0.4 1.4 0.5 3 0.4 179 29 159 305 8.4 0 8.4 8.2 09/19/2005 14:50:00 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 190 15 192 305 8.5 0 8.7 8.2 09/19/2005 15:00:00 1.3 0.9 3.4 0.4 1.6 0.9 3.8 0.4 214 28 221 305 8.6 0.1 8.9 8.2 09/19/2005 15:10:00 3.3 0.7 4.9 1.5 3.7 0.6 5.3 2.3 146 8 133 305 8.1 0 8.4 7.9 09/19/2005 15:20:00 3.8 0.4 4.9 2.3 4.1 0.4 4.9 2.6 146 6 150 305 7.7 0.1 8.2 7.7 09/19/2005 15:30:00 3.5 0.6 4.9 1.5 3.8 0.5 4.9 1.9 139 10 137 305 7.5 0 7.9 7.4 09/19/2005 15:40:00 3.7 0.3 4.6 3 3.9 0.3 4.6 3 141 6 146 305 7.5 0 8.2 7.4 09/19/2005 15:50:00 3.5 0.3 4.6 2.6 3.8 0.3 4.6 3 141 6 142 305 7.5 0 7.9 7.4 09/19/2005 16:00:00 2.8 0.4 3.8 1.9 3.2 0.3 3.8 2.3 140 6 144 305 7.7 0.1 8.2 7.7 09/19/2005 16:10:00 2.7 0.5 3.8 1.1 3.1 0.4 4.2 1.9 143 8 150 305 7.8 0.1 8.2 7.7 09/19/2005 16:20:00 1.7 0.8 3.8 0.4 2.2 0.8 4.2 0.4 149 15 145 305 8 0.1 8.7 7.7 09/19/2005 16:30:00 2.3 0.9 4.2 0.4 2.9 0.8 4.9 1.1 156 18 149 305 8.4 0.1 8.9 8.2 09/19/2005 16:40:00 2.9 0.9 4.6 1.1 3.5 0.6 4.9 2.3 154 10 151 305 8 0 8.2 7.9 09/19/2005 16:50:00 3.1 0.5 4.2 1.5 3.5 0.4 4.6 2.3 143 6 139 305 7.9 0 8.2 7.7 09/19/2005 17:00:00 2.9 0.6 4.6 1.1 3.3 0.5 4.6 1.9 140 8 144 305 7.9 0 8.4 7.7 09/19/2005 17:10:00 3.6 0.5 4.6 2.3 3.9 0.4 4.9 3 133 7 136 305 7.7 0 7.9 7.7 09/19/2005 17:20:00 4 0.3 4.9 3.4 4.2 0.3 4.9 3.4 143 6 151 305 7.5 0 7.7 7.4 09/19/2005 17:30:00 3.4 0.4 4.6 2.3 3.6 0.4 4.9 2.3 140 7 146 305 7.1 0 7.7 6.9 09/19/2005 17:40:00 2.8 0.9 4.2 0.4 3.2 0.6 4.9 1.5 148 12 139 305 6.9 0 7.4 6.9 09/19/2005 17:50:00 2.1 0.5 3 0.7 2.6 0.4 3.4 1.5 148 12 149 305 6.9 0 7.2 6.9 09/19/2005 18:00:00 3.5 0.4 4.2 1.9 3.7 0.4 4.6 2.3 135 4 135 305 6.9 0 7.4 6.9 09/19/2005 18:10:00 3.3 0.6 4.6 2.3 3.6 0.5 4.6 2.6 132 5 133 305 6.8 0 6.9 6.7 09/19/2005 18:20:00 3.3 0.5 4.6 2.3 3.6 0.5 4.9 2.6 131 6 134 305 6.9 0 7.4 6.9 09/19/2005 18:30:00 3.2 0.8 4.9 0.4 3.5 0.7 4.9 1.1 132 10 130 305 6.8 0 6.9 6.9 09/19/2005 18:40:00 2.5 1 4.6 0.4 2.9 0.8 4.9 1.1 137 17 139 305 6.8 0 7.2 6.9 09/19/2005 18:50:00 3.1 0.6 5.3 1.5 3.6 0.5 4.9 2.3 135 10 150 305 7 0 7.2 6.9 09/19/2005 19:00:00 2.5 0.7 4.9 0.4 3 0.6 4.6 1.1 154 10 148 305 6.9 0 7.2 6.9 09/19/2005 19:10:00 1.2 0.7 2.6 0.4 2.1 0.5 3 0.7 163 15 164 305 7 0 7.2 6.9 09/19/2005 19:20:00 1.8 0.7 3.4 0.4 2.5 0.5 3.8 1.1 163 13 150 305 7.1 0.1 7.7 6.9 09/19/2005 19:30:00 1.6 0.8 3.4 0.4 2.5 0.5 4.2 1.1 177 13 194 305 7 0 7.7 6.9 09/19/2005 19:40:00 3.3 0.7 4.9 1.5 3.3 0.6 4.6 2.3 229 26 238 305 7 0 7.7 6.9 09/19/2005 19:50:00 3.4 0.4 4.2 2.3 2.9 0.4 4.2 1.9 256 5 261 305 6.7 0.1 7.2 6.7 09/19/2005 20:00:00 2.9 0.5 3.8 1.5 2.7 0.5 3.8 1.9 249 6 242 305 6.7 0 7.2 6.4 09/19/2005 20:10:00 2.8 0.5 3.8 1.5 2.7 0.4 3.8 1.5 232 6 239 305 6.6 0 6.9 6.7 09/19/2005 20:20:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 228 5 227 305 6.7 0 7.2 6.7 09/19/2005 20:30:00 2.5 0.6 3.4 0.4 2.6 0.5 3.4 1.5 226 8 229 305 6.6 0 6.9 6.4 09/19/2005 20:40:00 4.4 1.2 6.1 1.5 4.5 1.1 6.1 1.9 203 6 203 305 6.7 0 6.9 6.4 09/19/2005 20:50:00 4.2 0.5 5.3 2.3 4.2 0.5 5.3 2.6 202 9 199 305 6.8 0 7.4 6.7 09/19/2005 21:00:00 3.3 0.5 4.6 1.9 3.3 0.4 4.6 2.3 219 4 221 305 6.7 0 7.2 6.7 09/19/2005 21:10:00 1.8 0.5 2.6 0.7 2.2 0.3 3 1.5 214 9 213 305 6.7 0 7.2 6.7 09/19/2005 21:20:00 1.6 0.4 2.3 0.7 2.3 0.3 3 1.5 188 8 188 305 6.7 0 6.9 6.7 09/19/2005 21:30:00 2.5 1.3 5.7 0.4 3.2 1.1 5.7 1.5 188 11 188 305 6.6 0 6.9 6.4 09/19/2005 21:40:00 3.4 0.8 5.3 1.5 3.8 0.9 6.1 1.9 188 9 184 305 6.5 0 6.7 6.1 09/19/2005 21:50:00 2.4 0.4 3.4 1.1 2.9 0.4 3.8 1.9 187 5 194 305 6.2 0 6.4 6.1 09/19/2005 22:00:00 1.5 0.5 3 0.4 2.8 0.4 3.8 1.9 170 5 179 305 6 0 6.1 5.9 09/19/2005 22:10:00 2.5 1 4.6 1.1 3.5 0.6 5.3 2.3 180 8 182 305 6 0 6.1 5.9 09/19/2005 22:20:00 5.3 0.9 7.2 2.6 5.8 0.8 7.6 3.8 185 5 192 305 5.9 0 6.1 5.6 09/19/2005 22:30:00 3.4 1 6.1 0.7 3.9 1 6.5 2.3 186 6 192 305 5.5 0 5.9 5.4 09/19/2005 22:40:00 2.4 0.6 4.2 1.1 3.5 0.6 5.3 1.9 176 8 179 305 5.6 0 5.9 5.4 09/19/2005 22:50:00 3 0.6 4.9 1.5 4.4 0.4 5.3 3 167 6 156 305 5.8 0 5.9 5.6 09/19/2005 23:00:00 3 0.8 4.9 1.5 4 0.5 5.3 3 166 8 169 305 5.6 0 5.6 5.4 09/19/2005 23:10:00 4 0.9 5.7 1.5 4.3 0.5 5.7 3 152 9 155 305 5.5 0 5.6 5.4 09/19/2005 23:20:00 4.5 0.8 6.1 2.3 4.5 0.6 5.7 3.4 149 7 137 305 5.4 0 5.6 5.4 09/19/2005 23:30:00 4 1 6.8 1.9 4.9 1 7.2 2.6 173 11 188 305 5.6 0.2 6.1 5.4 09/19/2005 23:40:00 4.1 0.8 6.5 2.6 5.7 0.7 7.6 4.6 174 7 183 305 6.3 0 6.4 5.9 09/19/2005 23:50:00 4.7 0.9 7.2 2.3 5.7 0.8 7.2 3.8 169 12 198 305 6.5 0 6.7 6.1 09/20/2005 00:00:00 4.6 0.6 6.8 2.6 4.6 0.6 6.1 3 147 9 154 305 6 0.1 6.9 5.9 09/20/2005 00:10:00 5 0.5 6.8 3.8 4.9 0.4 6.5 3.8 140 6 148 305 5.6 0.1 5.9 5.4 09/20/2005 00:20:00 5.3 0.5 6.5 4.2 5.2 0.5 6.5 4.2 139 5 149 305 5.5 0 5.6 5.4 09/20/2005 00:30:00 5.7 0.4 6.5 4.6 5.5 0.4 6.5 4.2 139 4 137 305 5.5 0 5.6 5.4 09/20/2005 00:40:00 5.7 0.4 6.8 4.6 5.4 0.4 6.5 4.2 139 4 145 305 5.5 0 5.6 5.4 09/20/2005 00:50:00 5.7 0.5 6.5 4.2 5.5 0.5 6.5 4.2 139 5 134 305 5.5 0 5.6 5.4 09/20/2005 01:00:00 5.1 0.6 6.5 3 5 0.6 6.8 3.4 144 7 150 305 5.5 0 5.6 5.4 09/20/2005 01:10:00 5.4 0.7 7.2 3.8 5.2 0.6 6.8 3.8 148 7 152 305 5.6 0 5.9 5.4 09/20/2005 01:20:00 5.1 0.8 6.8 3 4.9 0.7 6.8 3.4 146 10 151 305 5.9 0 5.9 5.6 09/20/2005 01:30:00 5 0.7 6.8 3.4 5.1 0.7 7.2 3.4 141 9 140 305 5.9 0 5.9 5.9 09/20/2005 01:40:00 6.1 0.8 8 4.2 5.8 0.8 8 3.8 139 8 147 305 5.9 0 5.9 5.9 09/20/2005 01:50:00 6.6 0.6 8.4 4.6 6.4 0.5 7.6 4.6 140 6 137 305 6 0 5.9 5.9 09/20/2005 02:00:00 6.8 0.6 8.4 4.9 6.7 0.5 8 4.9 140 6 144 305 6 0 6.1 5.9 09/20/2005 02:10:00 7.5 0.7 8.8 4.9 7.2 0.8 8.8 4.6 136 5 142 305 6 0 6.1 5.9 09/20/2005 02:20:00 7.7 0.6 8.8 5.7 7.6 0.6 8.8 5.7 135 5 137 305 6.1 0 6.4 6.1 09/20/2005 02:30:00 7.4 0.8 8.8 4.6 7.2 0.8 8.8 4.2 136 6 140 305 6.2 0 6.4 6.1 09/20/2005 02:40:00 6.4 1 9.5 3.8 6.3 1 9.1 3.8 135 11 149 305 6.3 0 6.4 6.1 09/20/2005 02:50:00 5.9 1 9.1 3.4 5.9 1 8.8 4.2 132 13 159 305 6.4 0 6.4 6.1 09/20/2005 03:00:00 6.5 1.1 8.8 3.8 6.3 1 8.8 3.8 132 11 128 305 6.5 0 6.7 6.4 09/20/2005 03:10:00 6.4 1 9.1 3.8 6.3 1.1 9.5 3.8 138 11 137 305 6.5 0 6.7 6.4 09/20/2005 03:20:00 6.8 1 8.8 3.8 6.6 1 9.1 4.2 136 7 139 305 6.5 0 6.7 6.4 09/20/2005 03:30:00 6.8 1 8.8 3 6.7 0.8 8.8 4.2 141 9 145 305 6.5 0 6.7 6.4 09/20/2005 03:40:00 5.8 1 9.1 3.4 5.8 0.8 8.4 3.4 147 12 147 305 6.5 0 6.7 6.4 09/20/2005 03:50:00 6.6 1 9.1 4.2 6.6 1 9.5 4.6 139 11 136 305 6.5 0 6.7 6.4 09/20/2005 04:00:00 7.3 1.1 10.3 4.9 7.1 1.1 9.9 4.2 137 9 145 305 6.6 0 6.9 6.4 09/20/2005 04:10:00 7.5 1.2 10.7 4.6 7.3 1.1 10.3 4.6 136 9 144 305 6.6 0 6.9 6.4 09/20/2005 04:20:00 7.5 1.1 10.3 4.6 7.2 1.1 10.3 4.9 138 9 154 305 6.7 0 6.9 6.7 09/20/2005 04:30:00 7.8 1.3 11.5 4.9 7.7 1.2 11.5 4.6 136 11 151 305 6.7 0 6.9 6.7 09/20/2005 04:40:00 6.1 1.5 10.3 2.6 6 1.4 9.9 3 129 17 140 305 6.7 0 6.9 6.4 09/20/2005 04:50:00 7 1.6 10.7 2.6 6.8 1.6 10.7 3 125 13 123 305 6.5 0 7.2 6.4 09/20/2005 05:00:00 6.4 1.4 9.9 3 6.3 1.4 10.3 3.4 127 14 121 305 6.5 0 6.7 6.4 09/20/2005 05:10:00 7.2 1.5 10.7 3.8 7 1.5 10.3 3.8 125 12 124 305 6.5 0 6.7 6.4 09/20/2005 05:20:00 6.8 1.2 10.7 3.4 6.6 1.1 11.8 4.2 130 14 140 305 6.5 0 6.7 6.4 09/20/2005 05:30:00 7 1.5 10.7 3.4 6.9 1.5 10.3 2.6 139 16 146 305 6.7 0 6.9 6.4 09/20/2005 05:40:00 8.4 1.4 11.8 4.9 8.1 1.3 11.5 5.3 140 12 137 305 6.9 0 7.2 6.7 09/20/2005 05:50:00 8.6 1.3 11.5 5.3 8.4 1.3 12.2 5.3 140 10 135 305 7 0 7.2 6.9 09/20/2005 06:00:00 7.7 1.4 10.7 4.2 7.6 1.2 10.7 4.2 143 12 148 305 7 0 7.2 6.9 09/20/2005 06:10:00 7.3 1.3 11.5 3.8 7.2 1.2 10.7 4.6 148 11 154 305 7 0 7.4 7.2 09/20/2005 06:20:00 8.1 1.6 12.6 4.6 7.8 1.3 11.5 4.2 147 12 149 305 7.2 0 7.4 7.2 09/20/2005 06:30:00 7.4 1.3 11.1 4.2 7.4 1.1 10.7 4.6 151 12 149 305 7.2 0 7.4 7.2 09/20/2005 06:40:00 7.8 1.6 11.1 4.2 7.9 1.3 11.1 4.2 153 13 156 305 7.2 0 7.4 7.2 09/20/2005 06:50:00 8.1 1.8 13 4.2 8.4 1.4 11.8 5.3 155 10 152 305 7.3 0 7.4 7.2 09/20/2005 07:00:00 8.7 1.5 11.8 4.6 8.8 1.2 12.2 5.7 152 10 131 305 7.3 0 7.4 7.2 09/20/2005 07:10:00 8.7 1.6 12.2 4.6 8.8 1.3 11.5 5.3 155 8 154 305 7.3 0 7.4 7.2 09/20/2005 07:20:00 7.7 1.2 10.3 4.6 7.9 1 10.3 5.3 154 9 151 305 7.3 0 7.4 7.2 09/20/2005 07:30:00 8.7 1.1 11.1 4.2 8.5 1 11.1 6.1 150 8 142 305 7.2 0 7.4 7.2 09/20/2005 07:40:00 7 1.2 10.7 3.8 7.1 0.9 10.3 4.9 152 10 153 305 7.3 0 7.4 7.2 09/20/2005 07:50:00 6.9 1.1 9.1 3.4 6.7 0.8 9.5 4.9 151 9 155 305 7.3 0 7.4 7.2 09/20/2005 08:00:00 7.5 1.1 11.1 3.8 7.3 1 9.9 4.9 149 7 141 305 7.3 0 7.4 7.2 09/20/2005 08:10:00 7.4 1 10.3 5.3 7.3 0.9 9.9 4.9 149 8 142 305 7.3 0 7.7 7.2 09/20/2005 08:20:00 8 1.3 10.7 4.2 7.8 1 9.9 4.2 150 8 156 305 7.5 0 7.7 7.4 09/20/2005 08:30:00 7.7 1.3 10.7 4.2 7.6 1.1 10.3 4.6 150 8 159 305 7.5 0 7.7 7.4 09/20/2005 08:40:00 7.8 1.3 10.7 3.8 7.9 1.1 11.1 5.3 151 9 148 305 7.5 0 7.7 7.7 09/20/2005 08:50:00 8.1 1.2 10.7 4.9 7.8 0.9 9.9 5.7 150 9 154 305 7.6 0 7.7 7.7 09/20/2005 09:00:00 8.1 1.1 10.3 3.8 7.9 0.9 9.9 5.7 149 8 150 305 7.6 0 7.7 7.7 09/20/2005 09:10:00 7.8 1.3 10.7 3.8 7.8 1 9.9 4.6 151 9 163 305 7.6 0 7.9 7.7 09/20/2005 09:20:00 7.5 1.2 10.3 4.2 7.6 1 10.7 5.3 150 10 147 305 7.6 0 7.7 7.7 09/20/2005 09:30:00 6.8 1.3 9.9 3.8 7 1 9.9 4.2 152 10 145 305 7.7 0 7.7 7.7 09/20/2005 09:40:00 7.8 1.2 10.7 4.6 7.5 1.2 10.7 5.3 148 9 156 305 7.7 0 7.9 7.7 09/20/2005 09:50:00 8.1 1 10.7 5.7 8 1 11.1 4.6 149 8 162 305 7.7 0 7.9 7.7 09/20/2005 10:00:00 8 1 10.3 5.3 7.9 0.8 10.3 5.3 149 8 150 305 7.7 0 7.9 7.7 09/20/2005 10:10:00 7.9 1 9.9 5.3 7.8 0.9 10.3 5.3 147 9 155 305 7.8 0 7.9 7.7 09/20/2005 10:20:00 7.7 1 9.9 4.6 7.6 0.8 9.9 5.3 149 7 141 305 7.8 0 7.9 7.7 09/20/2005 10:30:00 6.2 1.1 9.5 3.4 6.5 1 9.1 4.2 152 10 157 305 7.9 0 8.2 7.7 09/20/2005 10:40:00 6.6 1.1 9.9 3 6.6 1 9.1 4.6 152 9 145 305 8 0 8.2 7.9 09/20/2005 10:50:00 6.3 1 8.8 3.8 6.7 0.8 9.1 4.9 157 9 148 305 8.1 0 8.7 7.9 09/20/2005 11:00:00 6.3 1.2 9.9 3 7 0.8 8.8 5.3 159 7 149 305 8.2 0.1 8.9 8.2 09/20/2005 11:10:00 5.1 1 8.4 2.6 6.8 0.9 9.5 4.2 165 6 156 305 8.6 0 9.2 8.2 09/20/2005 11:20:00 5.7 1 9.1 2.6 8.1 0.8 10.7 6.1 167 6 156 305 8.8 0 8.9 8.7 09/20/2005 11:30:00 5.9 1.2 9.1 3 7.5 1 9.5 5.3 163 7 155 305 8.8 0 9.2 8.7 09/20/2005 11:40:00 5.5 1.1 8.4 3.4 6.9 0.8 9.5 4.6 163 7 159 305 8.8 0 8.9 8.7 09/20/2005 11:50:00 6.3 1.2 9.5 3.4 7.1 1 9.9 4.9 159 9 147 305 8.8 0 8.9 8.7 09/20/2005 12:00:00 6.2 1.2 9.1 3.8 7.5 0.8 9.5 5.3 163 7 154 305 8.8 0 9.2 8.7 09/20/2005 12:10:00 6.2 1.1 9.1 3.8 7.5 0.8 9.9 5.3 161 8 158 305 8.7 0 8.9 8.7 09/20/2005 12:20:00 6 1.1 9.1 3.8 7.6 0.8 9.5 5.7 163 7 167 305 8.6 0 8.7 8.4 09/20/2005 12:30:00 6.2 1.3 9.9 3.4 8.3 1 10.7 5.3 165 6 155 305 8.7 0 8.9 8.7 09/20/2005 12:40:00 6.4 1 9.1 4.2 9.4 1 11.5 6.5 168 6 172 305 8.9 0 9.2 8.9 09/20/2005 12:50:00 6.7 1.1 9.9 4.6 9.7 0.8 11.5 6.8 167 5 156 305 9.1 0 9.2 8.9 09/20/2005 13:00:00 6.5 1.1 10.3 3.8 9.7 1 12.2 6.8 166 5 159 305 9.1 0 9.5 9.2 09/20/2005 13:10:00 6.4 1 9.1 4.6 9.4 1 11.5 6.5 166 5 159 305 9.2 0 9.5 9.2 09/20/2005 13:20:00 6.1 1 9.5 4.2 8.9 0.8 10.7 6.8 165 5 158 305 9.2 0 9.7 9.2 09/20/2005 13:30:00 5.9 1 9.5 4.2 8.8 1.1 11.1 6.1 166 6 163 305 9.2 0 9.7 9.2 09/20/2005 13:40:00 5.9 1.1 9.5 3.4 8.3 0.9 10.7 6.1 167 6 155 305 9.3 0 9.7 9.2 09/20/2005 13:50:00 5.4 1 8.4 3 7.3 0.9 9.5 4.9 170 8 182 305 9.3 0 9.7 9.2 09/20/2005 14:00:00 5.7 1 8.8 3 8.1 0.9 10.7 5.7 168 6 161 305 9.2 0 9.5 9.2 09/20/2005 14:10:00 5.8 1.1 8.4 3.4 8 0.9 10.3 5.3 171 7 163 305 9.3 0 9.5 9.2 09/20/2005 14:20:00 5.5 0.9 8.4 3.4 7.4 1 10.3 5.3 170 7 163 305 9.3 0 9.5 9.2 09/20/2005 14:30:00 5.7 1.1 8.4 3.4 7.8 1.1 10.7 4.9 168 7 189 305 9.3 0 9.7 9.2 09/20/2005 14:40:00 6.2 1.1 9.9 3.4 8.7 1.1 11.5 6.1 167 7 159 305 9.4 0 9.7 9.5 09/20/2005 14:50:00 6.1 1.1 9.9 3.8 8.5 1 11.1 6.1 168 7 166 305 9.4 0 9.7 9.2 09/20/2005 15:00:00 6.3 1.1 10.3 4.2 8.8 1.5 12.2 5.3 168 7 160 305 9.3 0.1 10 9.2 09/20/2005 15:10:00 6.5 1 9.5 4.6 9.9 1 12.6 6.5 167 5 159 305 9.3 0.1 9.7 9.2 09/20/2005 15:20:00 6.3 1 9.1 4.2 8.9 0.9 11.5 6.5 169 7 158 305 9.3 0 9.7 9.2 09/20/2005 15:30:00 6.6 1.2 10.7 3.4 9.4 1.2 13 6.1 167 6 159 305 9.3 0 9.7 9.2 09/20/2005 15:40:00 6.5 1.1 9.9 4.2 9 0.9 11.1 6.1 167 6 152 305 9.3 0.1 9.7 9.2 09/20/2005 15:50:00 6.3 1.2 9.1 3 8.7 0.9 10.7 5.3 165 6 169 305 9.2 0 9.7 9.2 09/20/2005 16:00:00 6.1 1.1 8.8 3.8 8.3 0.8 10.7 6.1 167 6 158 305 9.3 0 9.5 9.2 09/20/2005 16:10:00 6 1.2 10.7 3 8.2 1.1 11.1 5.3 167 7 158 305 9.2 0 9.5 9.2 09/20/2005 16:20:00 6.4 1.1 9.9 4.6 8.9 1.1 11.5 6.1 165 6 157 305 9.1 0 9.2 8.9 09/20/2005 16:30:00 6.4 1 10.3 4.2 9.2 1.2 11.8 6.1 167 6 158 305 9 0 9.5 8.9 09/20/2005 16:40:00 6.2 1.1 9.1 3.8 8.3 0.9 10.7 6.1 167 8 156 305 9.1 0 9.2 9.2 09/20/2005 16:50:00 6.2 1.2 9.5 3.8 7.8 1 10.7 4.9 163 9 151 305 9.1 0 9.7 8.9 09/20/2005 17:00:00 6.1 1.2 9.1 3.4 7.3 1.1 10.3 4.6 161 9 156 305 8.9 0 9.5 8.4 09/20/2005 17:10:00 6.2 1.3 10.3 3.8 7.7 0.9 9.9 5.3 162 8 150 305 8.9 0 9.5 8.9 09/20/2005 17:20:00 6.2 1.3 10.3 3.4 8.2 1 11.8 5.7 165 7 153 305 9 0 9.5 8.9 09/20/2005 17:30:00 6.5 1.4 11.1 3.8 8.6 0.8 11.1 6.5 165 7 146 305 9 0 9.2 8.9 09/20/2005 17:40:00 6.6 1.3 10.7 3.4 8.2 1 10.3 5.7 163 8 156 305 9 0 9.5 8.9 09/20/2005 17:50:00 6.4 1.2 9.5 3.4 7.6 0.9 9.9 5.3 160 8 148 305 8.9 0 9.2 8.9 09/20/2005 18:00:00 6.5 1.3 9.5 3.4 7.4 1 10.3 4.6 159 10 153 305 8.9 0 9.5 8.9 09/20/2005 18:10:00 6 1.3 9.5 3 6.9 1 10.3 4.2 159 12 150 305 8.9 0 9.2 8.9 09/20/2005 18:20:00 6.5 1.4 10.3 2.6 7 1.1 10.7 4.6 156 14 155 305 8.9 0 9.2 8.9 09/20/2005 18:30:00 5.8 1.5 10.7 3 6.5 1 10.3 4.6 157 14 129 305 8.9 0.1 9.2 8.9 09/20/2005 18:40:00 7.1 1.6 11.1 4.2 7.7 1.3 11.1 4.9 155 11 149 305 8.7 0 9.2 8.4 09/20/2005 18:50:00 7.1 1.5 11.1 4.2 7.9 1.3 11.8 4.9 157 12 153 305 8.6 0 8.9 8.4 09/20/2005 19:00:00 6.9 1.4 10.3 3.8 7.4 1.1 9.9 4.9 155 13 150 305 8.5 0 8.9 8.4 09/20/2005 19:10:00 6.9 1.4 11.1 3 7 1.2 10.3 4.6 149 11 145 305 8.4 0.1 8.9 8.2 09/20/2005 19:20:00 7.3 1.5 12.6 3.4 7.5 1.2 12.6 3.8 150 12 141 305 8.3 0.1 8.9 8.2 09/20/2005 19:30:00 7.7 1.5 11.5 3.4 7.7 1.1 11.1 4.6 149 13 153 305 8.2 0 8.7 8.2 09/20/2005 19:40:00 8.5 1.8 12.2 3.8 8.5 1.5 12.6 5.3 149 11 133 305 8.2 0.1 8.7 8.2 09/20/2005 19:50:00 7.2 1.5 10.3 3.4 7.5 1.2 10.7 3.8 150 13 153 305 8.2 0 8.7 8.2 09/20/2005 20:00:00 7.6 1.7 11.8 4.2 7.9 1.5 11.8 4.6 151 13 143 305 8.2 0.1 8.7 8.2 09/20/2005 20:10:00 9.1 1.4 13.3 4.9 9 1.3 13.7 5.3 146 9 150 305 8.2 0 8.7 8.2 09/20/2005 20:20:00 8.7 1.5 13 5.7 8.5 1.5 13 5.3 143 11 148 305 8.2 0 8.7 8.2 09/20/2005 20:30:00 8.3 1.2 11.5 5.3 8.3 1 11.8 5.7 142 11 138 305 8.2 0 8.2 8.2 09/20/2005 20:40:00 8.8 1.5 13 4.9 8.8 1.3 11.8 4.9 144 11 151 305 8.1 0 8.2 8.2 09/20/2005 20:50:00 9.9 1.4 13 6.1 9.7 1.3 14.1 6.5 141 11 127 305 8.1 0 8.2 8.2 09/20/2005 21:00:00 10.6 1.5 15.3 6.5 10.4 1.5 14.9 7.2 136 9 133 305 8.1 0 8.2 8.2 09/20/2005 21:10:00 10.6 1.5 14.5 6.5 10.5 1.5 15.3 6.5 134 9 147 305 8.1 0 8.2 8.2 09/20/2005 21:20:00 10.4 1.3 14.5 6.1 10.3 1.5 13.7 5.3 136 10 122 305 8.1 0 8.2 7.9 09/20/2005 21:30:00 10.5 1.6 14.9 6.8 10.5 1.5 14.9 5.3 135 10 130 305 8.1 0 8.4 7.9 09/20/2005 21:40:00 10.8 1.3 14.5 5.7 10.7 1.3 14.5 6.1 136 9 136 305 8 0 8.4 7.9 09/20/2005 21:50:00 10.9 1.3 14.1 6.8 10.7 1.3 15.6 6.8 133 8 136 305 8 0 8.4 7.9 09/20/2005 22:00:00 10.5 1.3 13.7 6.5 10.2 1.3 13.3 5.7 136 8 127 305 8 0 8.2 7.9 09/20/2005 22:10:00 8.7 1.7 14.1 4.2 8.5 1.6 13 3.4 137 14 145 305 7.9 0 7.9 7.9 09/20/2005 22:20:00 6.6 2 12.2 2.6 6.4 1.8 11.5 2.6 129 15 114 305 7.8 0 7.9 7.7 09/20/2005 22:30:00 7.9 2.4 13.7 3 7.7 2.3 14.1 3.4 135 17 131 305 7.8 0 7.9 7.7 09/20/2005 22:40:00 7.5 2.4 12.2 1.5 7.6 2.2 12.6 2.3 134 20 119 305 7.9 0 8.2 7.7 09/20/2005 22:50:00 8.2 1.6 12.2 2.6 8 1.4 11.5 4.2 130 17 152 305 7.8 0 7.9 7.7 09/20/2005 23:00:00 7.1 1.7 12.2 2.6 6.8 1.5 11.8 3 133 20 146 305 7.8 0 7.9 7.7 09/20/2005 23:10:00 7.7 2.1 14.1 3.4 7.7 1.8 13 3.8 135 17 140 305 7.7 0 7.9 7.7 09/20/2005 23:20:00 9.4 1.9 16.8 5.3 9.4 2 15.6 5.7 135 17 120 305 7.9 0 8.2 7.7 09/20/2005 23:30:00 8.6 1.8 15.3 4.6 8.8 1.7 13 4.9 137 17 165 305 7.9 0 7.9 7.7 09/20/2005 23:40:00 11.7 2.5 18.7 6.1 11.5 2.5 19.1 6.1 138 13 143 305 8 0 8.4 7.9 09/20/2005 23:50:00 12.1 2.3 17.9 5.7 11.7 2.1 17.2 6.5 135 11 144 305 8 0 8.2 7.9 09/21/2005 00:00:00 12.7 1.9 19.1 6.5 12.3 1.8 18.7 6.8 136 10 140 305 8.1 0 8.2 7.9 09/21/2005 00:10:00 12.4 2.1 19.1 7.2 12 2 19.9 7.6 135 11 139 305 8.1 0 8.2 8.2 09/21/2005 00:20:00 12.4 2 17.6 8.4 11.9 1.7 16.8 7.6 134 12 124 305 8.1 0 8.7 8.2 09/21/2005 00:30:00 13.1 1.7 17.2 7.6 12.8 1.6 17.2 8.4 136 10 145 305 8.2 0 8.7 8.2 09/21/2005 00:40:00 12.6 2.2 18.7 7.2 12.2 2.2 16.8 6.8 135 12 136 305 8.2 0 8.9 8.2 09/21/2005 00:50:00 12.6 2.1 17.6 6.8 12.3 2.1 17.6 6.1 135 11 105 305 8.2 0 8.7 8.2 09/21/2005 01:00:00 12.3 2.1 17.6 6.5 12.2 2 16.8 6.1 135 12 145 305 8.1 0 8.2 8.2 09/21/2005 01:10:00 11.1 2.3 16.8 4.9 11.1 2.4 16.8 6.5 136 12 130 305 8.2 0 8.2 8.2 09/21/2005 01:20:00 11.4 2.2 17.9 6.8 11.4 2 18.7 7.2 135 12 120 305 8.2 0 8.2 8.2 09/21/2005 01:30:00 11.8 2.1 17.6 7.6 11.5 2 17.2 6.8 136 12 127 305 8.2 0 8.2 8.2 09/21/2005 01:40:00 11.9 2.1 17.2 6.5 11.7 2.2 17.6 6.1 137 13 140 305 8.2 0 8.7 8.2 09/21/2005 01:50:00 13.4 2 18.7 7.2 13.3 1.9 18.7 7.6 134 10 149 305 8.1 0 8.2 7.9 09/21/2005 02:00:00 13.5 1.7 18.7 8.4 13.2 1.9 19.1 7.2 134 10 130 305 8.1 0 8.2 7.9 09/21/2005 02:10:00 13.7 1.9 17.9 7.6 13.5 1.7 17.9 8.4 136 9 137 305 8.1 0 8.2 7.9 09/21/2005 02:20:00 13.2 2.1 20.2 7.2 12.7 1.9 19.1 7.6 134 10 146 305 8.1 0 8.2 7.9 09/21/2005 02:30:00 12.4 2.1 17.9 6.1 12.1 2.1 17.6 5.3 134 11 134 305 8 0 8.2 7.9 09/21/2005 02:40:00 13.4 2 18.7 8 12.9 1.9 17.9 7.2 135 10 141 305 8 0 8.2 7.9 09/21/2005 02:50:00 12.5 2 17.2 4.9 12.3 1.9 17.2 7.6 134 12 120 305 8 0 8.2 7.9 09/21/2005 03:00:00 13.3 1.8 17.6 8.4 12.8 1.7 16.8 8.4 135 9 140 305 8 0 8.2 7.9 09/21/2005 03:10:00 13.1 1.6 17.9 8.4 12.9 1.6 18.3 9.1 133 8 141 305 8 0 8.2 7.9 09/21/2005 03:20:00 12.7 1.7 16.8 8.8 12.4 1.6 16.1 8 134 9 124 305 8 0 8.4 7.9 09/21/2005 03:30:00 11.7 2 17.9 6.1 11.5 1.9 18.3 6.8 135 11 133 305 8 0 8.2 7.9 09/21/2005 03:40:00 12 1.8 16.4 7.2 11.8 1.8 16.1 6.8 135 10 118 305 8.1 0 8.2 7.9 09/21/2005 03:50:00 11.3 2.1 16.4 5.7 11.1 2 16.4 6.5 136 12 131 305 8.1 0 8.4 7.9 09/21/2005 04:00:00 11.9 2 16.8 6.8 11.7 1.9 16.8 6.5 136 12 114 305 8.1 0 8.4 7.9 09/21/2005 04:10:00 11.2 1.8 16.1 6.5 11.2 1.8 15.6 6.8 137 14 134 305 8.1 0 8.7 7.9 09/21/2005 04:20:00 11.6 2.3 17.9 6.8 11.4 2.1 17.6 6.5 136 12 132 305 8.1 0 8.7 7.9 09/21/2005 04:30:00 11.7 2 16.4 6.5 11.6 1.9 18.3 6.8 135 12 121 305 8.1 0 8.7 7.9 09/21/2005 04:40:00 11.3 1.7 16.4 7.2 11 1.7 16.1 5.7 136 12 158 305 8.1 0 8.4 7.9 09/21/2005 04:50:00 11.3 2 17.9 6.1 11.2 2 16.1 6.5 136 12 137 305 8.1 0 8.7 8.2 09/21/2005 05:00:00 11.1 1.9 16.8 6.8 11.1 1.8 17.2 6.8 133 13 133 305 8.1 0 8.7 7.9 09/21/2005 05:10:00 10 1.9 15.6 5.3 10.1 1.8 15.3 5.7 141 14 144 305 8.1 0 8.7 7.9 09/21/2005 05:20:00 9.6 1.7 14.5 6.1 9.5 1.5 14.5 6.1 140 13 116 305 8.1 0 8.7 7.9 09/21/2005 05:30:00 10.3 2.2 15.6 4.9 10.2 2 15.6 5.3 144 13 145 305 8.1 0 8.4 7.9 09/21/2005 05:40:00 10.2 1.7 16.1 5.3 10.3 1.8 16.1 6.1 143 15 147 305 8.2 0 8.2 8.2 09/21/2005 05:50:00 10.8 2 16.4 6.5 11 2 16.8 6.1 145 12 146 305 8.2 0 8.4 8.2 09/21/2005 06:00:00 11.3 1.8 16.4 6.5 11.1 1.7 15.3 7.2 146 10 127 305 8.2 0 8.7 8.2 09/21/2005 06:10:00 11.2 1.8 15.6 6.1 11.1 1.7 16.1 6.8 146 11 155 305 8.3 0 8.4 8.2 09/21/2005 06:20:00 9.9 2.3 15.6 4.9 10 1.9 15.6 5.7 148 13 139 305 8.3 0 8.9 8.2 09/21/2005 06:30:00 10.2 2.3 15.3 5.3 10.2 1.9 16.4 5.3 150 12 143 305 8.3 0.1 8.9 8.2 09/21/2005 06:40:00 9.7 2.4 15.6 4.9 9.9 1.8 14.9 5.3 150 12 149 305 8.3 0.1 8.9 8.2 09/21/2005 06:50:00 10.9 2.7 17.9 4.6 11.3 2.3 17.2 5.7 150 12 137 305 8.2 0.1 8.9 8.2 09/21/2005 07:00:00 10.6 1.9 16.8 6.1 10.6 1.6 14.9 6.1 149 13 159 305 8.2 0 8.9 8.2 09/21/2005 07:10:00 10.7 1.9 15.3 5.3 10.8 1.6 14.9 7.2 148 13 118 305 8.2 0 8.9 8.2 09/21/2005 07:20:00 10.2 1.7 14.9 5.3 10.2 1.6 14.5 6.8 147 11 154 305 8.2 0 8.9 8.2 09/21/2005 07:30:00 10.9 1.7 15.3 6.1 10.7 1.7 14.9 7.2 146 10 150 305 8.1 0 8.4 8.2 09/21/2005 07:40:00 9.5 1.9 14.1 4.6 9.4 1.6 13.7 6.1 149 11 150 305 8.2 0 8.9 8.2 09/21/2005 07:50:00 8.9 1.8 13 4.6 9.1 1.5 13.3 5.3 150 13 133 305 8.3 0.1 8.9 8.2 09/21/2005 08:00:00 8.9 1.8 14.1 4.9 9.4 1.5 14.1 5.7 150 13 127 305 8.2 0.1 8.9 8.2 09/21/2005 08:10:00 8.9 1.8 13.3 4.6 9 1.6 13 4.9 149 13 137 305 8.3 0.1 8.9 8.2 09/21/2005 08:20:00 9.5 2.1 15.3 4.9 9.8 1.8 14.9 5.3 149 12 146 305 8.3 0.1 8.9 8.2 09/21/2005 08:30:00 10.6 1.9 14.5 5.7 10.8 1.5 14.5 7.2 148 10 143 305 8.4 0.1 8.9 8.2 09/21/2005 08:40:00 8.4 2.6 13.7 2.6 8.7 2.3 14.5 3.8 150 10 145 305 8.4 0 8.9 8.2 09/21/2005 08:50:00 6.5 1.7 10.3 2.3 6.8 1.4 10.7 2.6 153 15 147 305 8.4 0.1 9.2 8.2 09/21/2005 09:00:00 7.3 1.5 11.5 3.8 7.4 1.2 11.5 4.6 146 11 163 305 8.4 0 8.9 8.2 09/21/2005 09:10:00 7.7 1.3 11.5 3.4 7.7 1.1 10.7 4.9 146 9 148 305 8.4 0 8.9 8.2 09/21/2005 09:20:00 6.8 1.3 10.3 3.8 6.8 1.2 9.9 4.2 145 11 154 305 8.4 0 8.9 8.2 09/21/2005 09:30:00 6.5 1.2 10.3 3.4 6.7 1.2 10.7 4.2 146 11 148 305 8.4 0 8.9 8.2 09/21/2005 09:40:00 7.1 1.5 10.3 3 7.3 1.2 10.3 4.2 150 11 127 305 8.4 0 9.2 8.2 09/21/2005 09:50:00 8.1 1.5 11.8 3.8 8.1 1.4 11.5 3.8 148 9 147 305 8.6 0 9.2 8.4 09/21/2005 10:00:00 8.7 1.7 13.3 4.6 8.8 1.2 12.6 6.5 151 10 140 305 8.6 0 9.2 8.4 09/21/2005 10:10:00 7.6 1.7 12.6 4.2 8.5 1.3 11.5 5.3 157 11 154 305 8.8 0 9.2 8.7 09/21/2005 10:20:00 7.4 1.5 11.8 4.2 8.8 1.4 12.2 5.7 163 9 158 305 8.8 0 9.2 8.7 09/21/2005 10:30:00 7.9 1.6 12.2 4.6 9.7 1.1 12.6 6.8 161 8 154 305 8.8 0.1 9.2 8.7 09/21/2005 10:40:00 8.1 1.5 12.2 4.9 9 1.2 11.8 4.9 157 9 147 305 8.8 0 9.2 8.7 09/21/2005 10:50:00 7.7 1.6 12.2 4.6 9.1 1.1 12.2 6.1 160 8 149 305 8.7 0 9.2 8.7 09/21/2005 11:00:00 7.9 1.6 12.6 4.6 9.9 1 13.3 6.5 162 8 154 305 8.8 0.1 9.2 8.7 09/21/2005 11:10:00 8.3 1.7 13 4.2 10.6 0.9 13.3 8.4 161 7 155 305 8.9 0 9.2 8.9 09/21/2005 11:20:00 8.2 1.5 12.6 5.3 10.7 1.1 13.7 7.6 162 7 157 305 9 0 9.7 8.9 09/21/2005 11:30:00 7.9 1.3 11.8 5.3 11 1 13.7 8.4 166 6 154 305 9.2 0 9.7 9.2 09/21/2005 11:40:00 7.7 1.3 12.2 4.6 10.4 1.2 13.3 6.8 168 7 156 305 9.2 0 9.7 9.2 09/21/2005 11:50:00 7.7 1.2 11.8 4.9 10.3 1.2 13.3 7.6 167 8 174 305 9.2 0 9.7 9.2 09/21/2005 12:00:00 7.9 1.6 12.2 4.6 9.1 1.5 13.7 5.7 162 12 147 305 9.2 0 9.7 9.2 09/21/2005 12:10:00 7.1 1.4 10.7 4.2 8.1 1.3 11.5 4.2 161 12 155 305 9.2 0 9.7 9.2 09/21/2005 12:20:00 7.3 1.5 11.8 4.2 8.2 1.3 11.8 4.9 159 14 148 305 9.1 0 9.7 8.9 09/21/2005 12:30:00 7.8 1.7 12.6 4.6 8.3 1.3 12.6 5.7 155 11 144 305 9.1 0 9.5 8.9 09/21/2005 12:40:00 7.6 1.5 12.2 4.2 9 1.3 13 5.7 162 12 155 305 9.1 0 9.7 8.9 09/21/2005 12:50:00 7.4 1.8 13 3.4 8.2 1.5 12.2 4.9 155 15 151 305 9.1 0 9.7 8.9 09/21/2005 13:00:00 8.2 1.7 12.6 4.2 8.6 1.3 12.2 5.7 151 13 131 305 9.1 0 9.7 8.9 09/21/2005 13:10:00 8.9 1.8 13.3 4.2 9.1 1.4 12.6 5.7 150 13 157 305 9.2 0 9.7 9.2 09/21/2005 13:20:00 9.5 1.5 13.3 5.3 9.4 1.4 13.7 6.1 143 10 138 305 9.1 0 9.5 9.2 09/21/2005 13:30:00 9 1.9 13.7 4.6 9.2 1.5 13 5.7 148 10 149 305 9.1 0 9.7 8.9 09/21/2005 13:40:00 8 1.5 12.6 4.6 8.5 1.3 12.2 4.9 152 13 140 305 9.2 0 9.7 9.2 09/21/2005 13:50:00 8.5 1.8 12.2 3.8 8.7 1.6 13.3 4.9 148 11 150 305 9.2 0 9.7 9.2 09/21/2005 14:00:00 9.1 1.5 14.1 4.9 9.2 1.2 13.3 5.7 147 10 161 305 9.1 0 9.5 8.9 09/21/2005 14:10:00 8.3 1.9 12.2 3 8.4 1.5 13 4.6 147 12 145 305 8.9 0 9.5 8.9 09/21/2005 14:20:00 7 1.6 11.8 3.4 7.2 1.3 11.1 4.2 151 13 142 305 8.9 0 9.5 8.9 09/21/2005 14:30:00 7.5 1.5 11.5 3.8 8.4 1.2 11.5 5.7 158 12 149 305 9.1 0 9.7 8.9 09/21/2005 14:40:00 7.3 1.3 11.5 4.2 8.7 1.4 12.6 4.9 158 12 150 305 9.2 0 9.7 9.2 09/21/2005 14:50:00 7.5 1.5 12.2 4.2 8.9 1.3 12.6 6.1 160 9 150 305 9.2 0 9.7 9.2 09/21/2005 15:00:00 7.9 1.5 11.5 4.2 9.2 1.1 12.2 6.1 160 9 147 305 9.2 0 9.7 9.2 09/21/2005 15:10:00 8.3 1.7 13.3 4.9 10 1.3 14.5 6.8 159 8 150 305 9.2 0 9.7 9.2 09/21/2005 15:20:00 7.6 1.6 12.2 4.2 9.8 1 12.6 7.6 162 7 150 305 9.2 0 9.7 9.2 09/21/2005 15:30:00 6.8 1.2 11.1 4.2 9.4 1 11.8 6.5 169 6 173 305 9.2 0 9.7 9.2 09/21/2005 15:40:00 9 1.6 13 5.3 10.1 1 12.6 7.2 179 7 189 305 9.2 0 9.7 9.2 09/21/2005 15:50:00 9.9 1.1 13 5.7 10.1 1 13.3 7.2 184 5 184 305 9.1 0 9.7 8.9 09/21/2005 16:00:00 10.1 0.9 12.2 7.2 10 1 12.6 6.8 184 4 184 305 9 0 9.5 8.9 09/21/2005 16:10:00 11.2 1 13.3 8 10.9 1 13.3 8 188 4 195 305 8.9 0 9.5 8.9 09/21/2005 16:20:00 11.5 0.9 13 8 11.1 1 13.3 8 189 4 187 305 8.9 0 9.2 8.9 09/21/2005 16:30:00 11.6 0.8 13.3 9.5 11 1 13 8.4 189 4 186 305 8.8 0.1 9.2 8.7 09/21/2005 16:40:00 12.2 0.8 14.5 9.9 11.8 0.9 14.5 9.1 191 4 195 305 8.8 0 9.2 8.7 09/21/2005 16:50:00 11.9 0.9 14.5 8.8 11.5 1.1 13.7 8.8 191 4 207 305 8.7 0 9.2 8.4 09/21/2005 17:00:00 12.1 0.8 14.1 9.1 11.7 1 13.7 8.4 192 4 198 305 8.6 0 9.2 8.4 09/21/2005 17:10:00 12.3 0.8 14.1 9.9 11.9 0.9 14.1 9.1 193 3 197 305 8.5 0 8.9 8.4 09/21/2005 17:20:00 11.9 0.6 13.3 9.5 11.4 0.8 13.7 8.4 193 3 195 305 8.4 0 8.9 8.2 09/21/2005 17:30:00 11.8 0.7 13.7 9.5 11.3 0.9 13.7 8.8 194 3 187 305 8.3 0.1 8.9 8.2 09/21/2005 17:40:00 11.6 0.6 13.7 9.9 11.2 0.8 13.7 8.8 197 3 200 305 8.2 0.1 8.7 8.2 09/21/2005 17:50:00 11.9 0.6 13.7 10.3 11.3 0.8 13.3 8.8 198 3 201 305 8.2 0 8.7 8.2 09/21/2005 18:00:00 11.4 0.6 13.3 9.9 11 0.6 13 9.1 200 3 206 305 8.2 0.1 8.7 8.2 09/21/2005 18:10:00 11.9 0.7 14.1 9.5 11.5 0.7 13.3 8.8 202 4 206 305 8.1 0 8.7 8.2 09/21/2005 18:20:00 11.7 0.8 13.3 8 11.1 0.9 13 7.6 205 5 198 305 8.2 0.1 8.7 8.2 09/21/2005 18:30:00 11.3 0.9 13 8 10.5 1 12.6 7.6 206 5 208 305 8.2 0 8.7 8.2 09/21/2005 18:40:00 11.8 1.1 14.5 8.4 10.9 1.1 13.3 7.6 206 5 205 305 8.2 0.1 8.7 7.9 09/21/2005 18:50:00 13.4 1 16.1 10.7 12.5 1.1 16.1 9.5 213 6 213 305 8.2 0.1 8.7 8.2 09/21/2005 19:00:00 12.4 0.8 14.9 10.3 11.6 1 14.5 8.8 213 4 218 305 8.2 0 8.7 8.2 09/21/2005 19:10:00 11.5 1.1 14.9 8 10.3 1.1 13 7.2 208 6 227 305 8.1 0 8.7 7.9 09/21/2005 19:20:00 12.5 1 14.5 9.1 11.3 1.3 14.1 7.2 209 6 205 305 8.1 0 8.7 8.2 09/21/2005 19:30:00 13 0.8 15.3 9.9 12.2 1 14.9 9.9 212 4 216 305 8.1 0 8.7 7.9 09/21/2005 19:40:00 13.1 0.9 16.1 11.1 12.2 1.1 15.6 8.8 212 5 217 305 8.1 0 8.7 7.9 09/21/2005 19:50:00 12.8 1 15.3 9.9 11.9 1.3 15.3 7.6 211 5 212 305 8.1 0 8.7 7.9 09/21/2005 20:00:00 12 0.8 14.1 9.5 11.1 0.9 13.7 8.4 211 5 216 305 8 0 8.4 7.9 09/21/2005 20:10:00 12.7 0.7 14.5 10.3 11.9 1 14.1 8.4 212 4 213 305 8 0 8.4 7.9 09/21/2005 20:20:00 13.1 0.8 14.9 10.3 12 1 14.5 8.8 212 4 214 305 8 0 8.4 7.9 09/21/2005 20:30:00 13 0.8 14.9 11.1 12 1.1 15.3 8.8 211 5 218 305 8 0 8.4 7.9 09/21/2005 20:40:00 12.5 1 14.9 9.5 11.5 1.2 14.9 8 208 5 206 305 8 0 8.4 7.9 09/21/2005 20:50:00 12.2 1 14.1 8.8 11 1.2 13.3 8.4 208 6 213 305 8 0 8.4 7.9 09/21/2005 21:00:00 12.5 0.9 14.5 9.1 11.4 1 13.7 8.4 208 5 210 305 8 0 8.7 7.9 09/21/2005 21:10:00 12.2 0.9 14.5 8.8 11 1.1 13.7 7.6 209 5 210 305 8.1 0 8.7 8.2 09/21/2005 21:20:00 12.1 1.2 14.9 7.6 10.9 1.3 13.7 7.2 207 6 205 305 8.2 0 8.7 8.2 09/21/2005 21:30:00 13.2 0.9 15.6 10.3 12.1 1 15.3 8 209 5 210 305 8.3 0.1 8.9 8.2 09/21/2005 21:40:00 12.3 1 14.1 8.8 11.3 1.2 13.7 7.6 206 5 211 305 8.2 0.1 8.9 8.2 09/21/2005 21:50:00 12.5 0.7 14.1 10.3 12 0.9 14.5 9.1 204 4 200 305 8.2 0.1 8.7 8.2 09/21/2005 22:00:00 13.1 0.7 15.3 11.5 12.6 0.7 14.5 10.7 202 4 205 305 8.2 0.1 8.9 8.2 09/21/2005 22:10:00 13.1 0.8 15.3 10.3 12.4 1 14.5 9.9 204 4 203 305 8.3 0.1 8.9 8.2 09/21/2005 22:20:00 13.7 0.8 15.6 11.5 13.2 1 16.1 9.9 202 4 198 305 8.3 0.1 8.9 8.2 09/21/2005 22:30:00 13.4 1.2 16.8 9.5 12.7 1.3 15.6 9.1 205 5 208 305 8.2 0.1 8.7 8.2 09/21/2005 22:40:00 12.4 1.1 15.3 8.8 11.4 1.3 14.5 8 206 5 207 305 8.1 0 8.7 7.9 09/21/2005 22:50:00 11.4 1.1 14.1 8.4 10.3 1.2 13.3 7.2 206 5 208 305 8 0 8.7 7.9 09/21/2005 23:00:00 11.4 0.6 13 9.5 11.1 0.7 13 9.1 204 4 209 305 8 0 8.2 7.9 09/21/2005 23:10:00 10.6 0.7 12.2 8 10.1 0.8 12.2 6.8 203 4 202 305 8 0 8.2 7.9 09/21/2005 23:20:00 9.5 0.9 11.5 6.8 9 1 11.1 6.5 203 5 201 305 7.9 0 7.9 7.7 09/21/2005 23:30:00 10.6 0.7 12.6 8.8 10.2 0.7 12.2 8.4 200 3 198 305 8 0 8.2 7.9 09/21/2005 23:40:00 10.8 0.6 12.2 8.4 10.3 0.7 12.2 8 202 4 199 305 8.1 0 8.2 7.9 09/21/2005 23:50:00 11.4 0.7 13.7 9.5 10.9 0.8 13 8 202 4 205 305 8.2 0 8.2 7.9 09/22/2005 00:00:00 12 0.9 13.7 9.5 11.4 0.8 13.3 9.1 203 4 193 305 8.2 0 8.7 8.2 09/22/2005 00:10:00 12.3 1 14.5 8.8 11.3 1.2 13.7 8 206 6 203 305 8.3 0 8.4 8.2 09/22/2005 00:20:00 12.5 1.2 14.9 8.4 11.5 1.4 14.5 7.6 211 6 200 305 8.2 0 8.7 8.2 09/22/2005 00:30:00 12.1 1.2 14.9 7.6 11.1 1.3 14.1 6.1 210 5 213 305 8.2 0 8.9 7.9 09/22/2005 00:40:00 10.8 1 13 7.2 9.9 1.1 12.2 6.5 206 6 203 305 8.1 0 8.2 7.9 09/22/2005 00:50:00 10.4 0.8 12.6 8.4 9.9 0.8 11.8 6.8 203 5 205 305 8 0 8.2 7.9 09/22/2005 01:00:00 10 0.8 11.8 7.2 9.6 0.9 11.8 6.5 194 4 196 305 8 0 8.2 7.9 09/22/2005 01:10:00 10.3 0.7 12.2 8.4 9.9 0.9 11.8 7.6 194 4 199 305 8 0 8.2 7.9 09/22/2005 01:20:00 11.3 0.8 13.7 7.6 10.8 0.9 13 8 194 4 203 305 8.1 0 8.2 7.9 09/22/2005 01:30:00 11.5 0.7 13.3 9.5 11 0.8 13 8.8 198 3 198 305 8.1 0 8.2 8.2 09/22/2005 01:40:00 10.5 0.7 12.6 8.8 10 0.8 12.6 7.6 196 4 202 305 8.1 0 8.2 7.9 09/22/2005 01:50:00 10 0.6 11.5 8 9.6 0.7 11.5 7.2 192 4 196 305 8.1 0 8.2 8.2 09/22/2005 02:00:00 9.8 0.6 11.5 7.6 9.4 0.8 11.8 7.2 191 4 192 305 8.1 0 8.2 8.2 09/22/2005 02:10:00 9.4 0.8 11.5 6.8 9.1 0.9 11.5 6.8 189 5 192 305 8.1 0 8.2 8.2 09/22/2005 02:20:00 9.8 0.9 12.2 7.6 9.4 1 11.8 6.8 195 6 205 305 8.1 0 8.4 8.2 09/22/2005 02:30:00 8.4 0.9 10.3 6.1 8.2 1 10.3 5.7 189 4 192 305 8.1 0 8.4 7.9 09/22/2005 02:40:00 9.1 1.1 12.2 4.6 8.9 1 11.8 6.5 188 6 202 305 8 0 8.4 7.9 09/22/2005 02:50:00 8.9 1 11.1 6.5 8.6 1 11.1 6.1 191 5 192 305 7.9 0 8.2 7.7 09/22/2005 03:00:00 7.4 1.3 9.9 4.2 7.8 0.9 9.9 6.1 183 6 200 305 7.9 0 8.2 7.7 09/22/2005 03:10:00 6.9 0.9 9.1 4.6 7.6 0.7 9.5 5.3 181 4 186 305 7.8 0 7.9 7.7 09/22/2005 03:20:00 7.6 0.9 9.5 4.2 8 0.8 9.9 5.7 183 5 183 305 7.7 0 7.9 7.7 09/22/2005 03:30:00 7.4 1 9.5 3.8 8 0.7 9.5 5.3 182 5 186 305 7.6 0 7.7 7.7 09/22/2005 03:40:00 7 0.9 8.8 4.2 7.6 0.6 9.1 5.7 181 5 182 305 7.5 0 7.7 7.4 09/22/2005 03:50:00 4.8 1 7.2 2.6 6.2 0.8 8 3.8 174 7 174 305 7.5 0 7.7 7.4 09/22/2005 04:00:00 5.1 1 8 3.4 7 0.8 8.8 4.9 172 7 184 305 7.7 0 8.2 7.7 09/22/2005 04:10:00 5.5 1.1 8.4 3.4 7.5 0.9 9.5 5.3 171 7 179 305 7.9 0 7.9 7.7 09/22/2005 04:20:00 5.2 0.9 8 3 6.9 1 8.8 4.2 162 6 154 305 7.7 0 8.2 7.7 09/22/2005 04:30:00 4.9 0.9 7.6 3 5.8 0.8 7.6 4.2 158 6 162 305 7.6 0 7.7 7.4 09/22/2005 04:40:00 4.7 0.8 6.8 2.6 6.2 0.6 7.6 4.6 161 6 150 305 7.5 0 7.7 7.4 09/22/2005 04:50:00 3.6 0.8 5.7 1.5 4.6 0.6 6.1 2.6 161 9 149 305 7.5 0 7.7 7.4 09/22/2005 05:00:00 4.1 1 6.8 2.3 4.1 0.9 6.8 2.3 142 11 133 305 7.5 0 7.7 7.4 09/22/2005 05:10:00 4.5 0.8 6.5 2.3 4.6 0.8 6.8 2.6 135 10 147 305 7.3 0 7.4 7.2 09/22/2005 05:20:00 4.2 1.2 7.2 1.5 4.2 1 6.8 1.9 142 15 133 305 7.3 0 7.4 7.2 09/22/2005 05:30:00 4.4 1 7.2 1.9 4.7 0.9 7.2 2.6 146 12 146 305 7.2 0 7.4 7.2 09/22/2005 05:40:00 4.8 1 8 2.3 5 0.9 7.6 3.4 141 14 133 305 7.2 0 7.4 7.2 09/22/2005 05:50:00 4.2 1.1 7.2 1.9 4.6 1 7.6 2.3 144 15 138 305 7.1 0 7.2 7.2 09/22/2005 06:00:00 6.4 1.5 8.8 2.3 6.2 1.3 8.8 2.6 135 11 137 305 7 0 7.2 6.9 09/22/2005 06:10:00 6.4 1.2 9.5 3.8 6.3 1.1 9.5 4.2 132 12 136 305 7 0 7.2 6.9 09/22/2005 06:20:00 5 1.3 8.8 2.3 5 1.3 9.1 2.6 133 18 141 305 7 0 7.2 6.9 09/22/2005 06:30:00 4.8 1.5 9.5 1.1 4.7 1.5 8.8 1.9 120 28 130 305 6.9 0 7.2 6.9 09/22/2005 06:40:00 5.7 2 11.8 1.5 5.6 1.9 11.5 2.3 114 27 135 305 6.9 0 7.2 6.9 09/22/2005 06:50:00 6.8 1.5 11.1 3.4 6.6 1.5 10.7 2.6 114 21 123 305 6.8 0 6.9 6.9 09/22/2005 07:00:00 6.2 1.5 10.3 1.9 6 1.5 9.5 2.6 107 22 121 305 6.7 0 6.9 6.7 09/22/2005 07:10:00 5.7 1.6 9.9 1.1 5.5 1.5 9.9 1.5 78 33 67 305 6.7 0 6.9 6.7 09/22/2005 07:20:00 6.3 2.4 11.8 1.5 6.2 2.2 12.6 1.1 86 29 65 305 6.6 0 6.9 6.4 09/22/2005 07:30:00 11 2.1 17.6 6.1 10.4 2 16.1 6.5 108 14 103 305 6.6 0 6.9 6.4 09/22/2005 07:40:00 9.9 1.9 17.6 5.3 9.4 1.7 14.5 5.3 99 15 112 305 6.7 0 6.9 6.7 09/22/2005 07:50:00 9.1 1.6 14.9 4.9 8.8 1.7 14.5 4.6 79 13 65 305 6.8 0 6.9 6.7 09/22/2005 08:00:00 8.5 1 11.5 6.5 8.3 1.2 12.2 5.7 75 8 80 305 6.7 0 6.9 6.7 09/22/2005 08:10:00 9 0.9 11.5 7.2 8.8 1 11.5 6.5 73 5 73 305 6.7 0 6.9 6.4 09/22/2005 08:20:00 8.9 0.6 10.7 7.2 8.8 0.7 10.7 6.5 69 5 66 305 6.7 0 6.9 6.7 09/22/2005 08:30:00 9.5 0.8 11.8 7.6 9.2 0.8 11.5 7.2 75 6 77 305 6.7 0 6.9 6.7 09/22/2005 08:40:00 10.4 1.1 13.7 6.8 10.3 1.2 13.3 6.1 75 7 73 305 6.8 0 7.2 6.7 09/22/2005 08:50:00 10.9 1.2 14.9 8 10.8 1.3 15.3 6.1 73 9 73 305 7 0 7.2 6.9 09/22/2005 09:00:00 11.6 1.3 15.3 8.4 11.5 1.5 15.6 7.6 74 9 75 305 7 0 7.2 6.9 09/22/2005 09:10:00 11.6 1 14.9 8.8 11.4 1.1 14.5 8.8 74 6 87 305 7 0 7.2 6.9 09/22/2005 09:20:00 11.6 1 16.1 8.8 11.5 1.1 15.6 8.4 70 7 67 305 7 0 7.2 6.9 09/22/2005 09:30:00 12.4 0.9 14.9 9.9 12.3 1 14.5 8.8 68 5 66 305 7 0 7.2 6.9 09/22/2005 09:40:00 12.9 1 15.6 11.1 12.7 1 14.9 10.3 66 6 67 305 7 0 7.2 6.9 09/22/2005 09:50:00 13.5 1 15.6 9.5 13.2 1.1 15.6 9.1 66 5 71 305 7.2 0 7.4 7.2 09/22/2005 10:00:00 13.2 1.2 16.4 9.5 12.8 1.3 16.4 8.4 65 5 81 305 7.1 0 7.2 7.2 09/22/2005 10:10:00 13 1.2 16.4 9.1 12.4 1.3 15.6 7.6 65 6 65 305 7.1 0 7.2 7.2 09/22/2005 10:20:00 13.2 1.1 15.6 9.9 12.8 1.2 16.1 10.3 64 5 58 305 7.2 0 7.4 7.2 09/22/2005 10:30:00 12.9 1 15.3 10.7 12.6 1 14.5 9.9 62 5 77 305 7.2 0 7.4 7.2 09/22/2005 10:40:00 12.6 0.8 14.9 9.9 12.3 0.9 15.3 9.9 59 4 61 305 7.2 0 7.4 7.2 09/22/2005 10:50:00 12.8 0.7 14.9 10.7 12.5 0.8 14.5 10.3 56 4 64 305 7.3 0 7.4 7.2 09/22/2005 11:00:00 13.4 1 16.1 11.1 13.1 1.1 16.8 10.3 53 5 55 305 7.3 0 7.4 7.2 09/22/2005 11:10:00 14.3 1 17.2 11.5 13.9 1 16.8 11.5 53 5 52 305 7.3 0 7.4 7.2 09/22/2005 11:20:00 14.7 1.3 18.7 11.5 14.3 1.3 18.3 11.1 53 5 58 305 7.4 0 7.7 7.4 09/22/2005 11:30:00 15.3 1.2 19.1 11.8 14.9 1.3 18.7 11.8 53 5 58 305 7.5 0 7.7 7.4 09/22/2005 11:40:00 16 1.1 19.1 12.2 15.6 1.2 18.7 12.6 54 5 52 305 7.5 0 7.7 7.4 09/22/2005 11:50:00 16.4 1.3 19.9 12.6 15.9 1.5 20.6 11.8 52 5 54 305 7.5 0 7.7 7.4 09/22/2005 12:00:00 16.7 1.5 19.9 12.6 16.2 1.5 20.2 11.8 51 5 51 305 7.5 0 7.7 7.4 09/22/2005 12:10:00 16.8 1.3 20.2 13.7 16.4 1.3 19.9 13 54 5 56 305 7.5 0 7.7 7.4 09/22/2005 12:20:00 17.5 1.2 20.2 14.1 17.2 1.3 20.2 13.3 55 5 55 305 7.4 0 7.9 7.4 09/22/2005 12:30:00 16.6 1.1 20.6 13.7 16.2 1.2 20.2 13 55 5 60 305 7.3 0 7.4 7.4 09/22/2005 12:40:00 16.6 1.2 19.9 13 16.3 1.4 20.2 13 56 5 60 305 7.3 0 7.7 7.2 09/22/2005 12:50:00 16 1.1 19.9 13.3 15.5 1.3 18.3 11.5 59 5 56 305 7.4 0 7.4 7.4 09/22/2005 13:00:00 15.2 1.3 18.7 12.2 14.7 1.3 19.1 11.8 62 5 62 305 7.4 0 7.7 7.4 09/22/2005 13:10:00 14 1.1 17.6 11.1 13.5 1.2 16.8 10.3 63 5 68 305 7.4 0 7.7 7.4 09/22/2005 13:20:00 15 1 17.9 11.8 14.5 1.1 17.9 10.7 65 5 57 305 7.5 0 7.7 7.4 09/22/2005 13:30:00 14.3 2.1 19.5 8.8 14 2.1 18.7 9.1 69 6 73 305 7.7 0 7.9 7.7 09/22/2005 13:40:00 13.9 1.4 17.9 10.7 13.6 1.5 17.2 10.3 70 6 69 305 7.9 0 8.2 7.7 09/22/2005 13:50:00 13.8 1.3 19.5 9.1 13.4 1.5 17.9 8.4 69 7 91 305 8 0 8.2 7.9 09/22/2005 14:00:00 11.1 2.9 19.5 4.6 11.2 2.9 19.9 3.8 71 17 80 305 8.1 0 8.2 7.9 09/22/2005 14:10:00 5.1 2.2 11.8 1.5 5 2 11.5 0.7 102 30 66 305 8.1 0 8.2 8.2 09/22/2005 14:20:00 4 1.6 8 0.4 3.9 1.5 9.9 0.4 104 39 109 305 8.1 0 8.2 7.9 09/22/2005 14:30:00 4.4 2.1 10.3 0.4 4.5 2 11.5 0.7 113 39 114 305 8.2 0 8.2 8.2 09/22/2005 14:40:00 5.8 2.3 14.5 0.4 5.7 2 13.7 1.1 124 22 156 305 8.2 0 8.4 8.2 09/22/2005 14:50:00 6.1 1.9 11.1 1.9 6 1.7 11.5 2.3 118 26 91 305 8.2 0 8.4 8.2 09/22/2005 15:00:00 4.2 2.2 13.7 0.4 4.2 2 11.8 0.4 91 36 143 305 8.4 0 8.7 8.2 09/22/2005 15:10:00 4.4 1.7 8.8 0.4 4.4 1.7 9.5 0.4 81 36 66 305 8.2 0 8.4 7.9 09/22/2005 15:20:00 6 1.8 11.1 2.3 5.8 1.6 11.8 3 72 22 75 305 7.9 0 8.2 7.7 09/22/2005 15:30:00 6.9 2.4 13 0.7 6.9 2.3 13.3 2.6 61 23 38 305 7.8 0 7.9 7.7 09/22/2005 15:40:00 8.1 2 13.3 3.8 8.1 2 14.5 4.2 58 15 65 305 7.7 0.1 8.2 7.7 09/22/2005 15:50:00 8.6 2 14.9 3 8.5 2.3 14.5 1.9 64 17 61 305 7.7 0 8.2 7.7 09/22/2005 16:00:00 8 2.1 12.2 3.4 7.9 2.2 13 3.4 67 15 65 305 7.7 0.1 8.2 7.7 09/22/2005 16:10:00 9.4 1 12.6 6.5 9.2 1 12.2 6.5 70 8 69 305 7.9 0 8.4 7.7 09/22/2005 16:20:00 9.8 0.8 12.2 7.2 9.7 1 13 7.2 71 6 66 305 7.9 0 8.4 7.7 09/22/2005 16:30:00 9.9 0.8 12.6 7.6 9.6 0.9 12.2 7.2 69 6 72 305 7.7 0.1 8.4 7.7 09/22/2005 16:40:00 9.2 0.8 12.2 7.2 8.9 0.8 11.1 6.8 65 5 71 305 7.6 0 8.2 7.4 09/22/2005 16:50:00 10.9 0.9 12.6 8 10.6 1 12.6 8 70 4 68 305 7.5 0.1 8.2 7.4 09/22/2005 17:00:00 11.2 0.6 12.6 9.5 10.9 0.6 12.2 9.1 68 4 64 305 7.5 0 8.2 7.4 09/22/2005 17:10:00 10.5 0.7 11.8 8.4 10.2 0.8 12.2 8 63 4 65 305 7.6 0 8.2 7.4 09/22/2005 17:20:00 10.6 0.6 11.8 8.4 10.4 0.7 11.8 8.4 61 3 62 305 7.5 0.1 8.2 7.2 09/22/2005 17:30:00 10 0.7 11.8 8 9.8 0.7 11.5 7.6 53 4 53 305 7.2 0.1 7.7 7.2 09/22/2005 17:40:00 10.7 0.6 12.2 8.8 10.5 0.7 11.8 8.8 46 4 48 305 7 0 7.7 6.9 09/22/2005 17:50:00 10.7 0.7 12.2 8.8 10.6 0.7 11.8 8.4 48 3 46 305 7 0 7.2 6.9 09/22/2005 18:00:00 10.5 0.6 12.2 8.8 10.4 0.7 11.8 8 46 3 45 305 6.9 0 7.2 6.9 09/22/2005 18:10:00 10.1 0.8 11.8 7.6 10 0.9 11.8 7.6 43 3 42 305 6.9 0 7.2 6.9 09/22/2005 18:20:00 10.2 0.5 11.8 8.8 10.1 0.6 11.5 8 40 3 40 305 6.9 0 7.2 6.9 09/22/2005 18:30:00 10 0.6 11.5 8 9.9 0.7 11.5 7.6 35 3 36 305 6.9 0 7.2 6.9 09/22/2005 18:40:00 10.1 0.8 11.8 8.4 9.9 0.8 12.2 8 33 3 36 305 7 0 7.2 6.9 09/22/2005 18:50:00 11 0.6 12.6 9.5 10.8 0.6 12.6 9.1 33 3 31 305 6.9 0 7.2 6.9 09/22/2005 19:00:00 10.6 0.6 11.8 9.1 10.5 0.6 11.8 8.4 27 3 25 305 6.8 0 7.2 6.9 09/22/2005 19:10:00 10.6 0.6 11.8 9.1 10.5 0.7 12.2 8.8 24 3 27 305 6.8 0 6.9 6.7 09/22/2005 19:20:00 11 0.6 12.6 9.1 10.9 0.6 12.6 8.8 23 3 21 305 6.8 0 6.9 6.7 09/22/2005 19:30:00 11.3 0.6 12.6 9.5 11.3 0.7 13.3 9.1 20 4 21 305 6.7 0 6.9 6.7 09/22/2005 19:40:00 11.6 0.8 13.3 9.5 11.6 0.9 13.3 9.1 16 3 18 305 6.8 0 6.9 6.7 09/22/2005 19:50:00 10.7 0.7 12.6 9.1 10.7 0.7 12.6 9.1 15 3 17 305 6.8 0 6.9 6.7 09/22/2005 20:00:00 10.4 0.8 11.8 8 10.4 0.9 12.2 8 10 5 14 305 6.7 0 6.9 6.7 09/22/2005 20:10:00 9.1 0.9 11.1 6.8 9.1 0.9 11.1 6.8 1 4 0 305 6.8 0 6.9 6.7 09/22/2005 20:20:00 9 0.7 10.7 6.8 9.1 0.8 11.5 7.2 0 4 9 305 6.8 0 6.9 6.7 09/22/2005 20:30:00 8.5 0.8 10.3 6.8 8.8 0.8 10.3 6.5 352 3 353 305 6.9 0 7.2 6.9 09/22/2005 20:40:00 8.5 0.8 10.7 6.8 8.6 0.8 10.7 6.5 351 4 352 305 7 0 7.2 6.9 09/22/2005 20:50:00 9.4 0.7 11.1 6.8 9.5 0.7 11.1 6.5 351 4 346 305 6.9 0 7.2 6.9 09/22/2005 21:00:00 8.8 0.9 10.7 6.5 9 0.8 11.1 6.8 343 5 347 305 6.8 0 6.9 6.9 09/22/2005 21:10:00 8.3 0.7 9.9 6.1 8.5 0.7 10.3 6.5 335 5 337 305 6.8 0 6.9 6.9 09/22/2005 21:20:00 9.1 0.7 10.7 6.8 9.3 0.8 11.1 7.2 334 4 329 305 6.7 0 6.9 6.7 09/22/2005 21:30:00 7.9 0.6 9.1 5.7 8 0.7 9.5 5.3 330 4 336 305 6.7 0 6.9 6.7 09/22/2005 21:40:00 7.8 0.6 9.9 6.5 7.8 0.7 9.5 6.5 325 6 320 305 6.8 0 6.9 6.7 09/22/2005 21:50:00 8.1 0.6 9.5 6.5 8.1 0.7 9.5 6.5 320 6 323 305 6.9 0 7.2 6.9 09/22/2005 22:00:00 8.9 0.8 10.7 6.5 8.8 0.9 10.7 6.1 317 6 316 305 7 0 7.2 6.9 09/22/2005 22:10:00 9 0.8 11.5 7.2 8.7 0.8 11.1 6.8 313 11 317 305 7 0 7.2 6.9 09/22/2005 22:20:00 9.5 0.7 11.1 7.6 9.3 0.8 11.1 6.8 313 20 305 305 6.9 0 7.2 6.9 09/22/2005 22:30:00 9 0.6 10.7 6.8 8.8 0.7 10.7 6.5 312 12 348 305 6.9 0 7.2 6.9 09/22/2005 22:40:00 9.1 0.7 10.7 6.8 8.8 0.7 10.3 6.8 311 22 314 305 6.9 0 7.2 6.9 09/22/2005 22:50:00 9.6 0.8 11.1 7.2 9.1 0.8 11.1 6.8 309 18 6 305 6.9 0 7.2 6.9 09/22/2005 23:00:00 9 0.8 11.1 7.2 8.6 0.9 10.7 6.5 307 20 300 305 7 0 7.2 6.9 09/22/2005 23:10:00 9.2 0.8 11.5 6.8 8.7 0.9 10.7 6.5 302 14 297 305 7 0 7.2 6.9 09/22/2005 23:20:00 9 0.9 11.5 7.2 8.5 0.9 11.1 6.5 297 15 301 305 7 0 7.2 6.9 09/22/2005 23:30:00 9.1 1.2 12.2 5.7 8.3 1.2 11.8 5.7 289 7 293 305 7.1 0 7.2 7.2 09/22/2005 23:40:00 9.6 1.1 11.5 6.5 8.3 1.2 11.5 5.3 282 6 290 305 7.1 0 7.2 7.2 09/22/2005 23:50:00 9.6 1.1 12.6 6.8 7.8 1.1 11.5 4.9 277 8 280 305 7 0 7.2 6.9 09/23/2005 00:00:00 9 1.1 11.5 5.7 7.5 1.2 10.3 4.6 277 8 275 305 7 0 7.7 6.9 09/23/2005 00:10:00 8.5 0.9 10.3 5.7 6.8 1 9.1 4.2 271 9 283 305 7.2 0 7.4 7.2 09/23/2005 00:20:00 9 1 11.5 5.7 7.1 1 9.9 4.2 272 8 275 305 7.4 0 7.7 7.2 09/23/2005 00:30:00 8.9 1.1 11.5 5.7 7 1 9.9 4.6 260 9 268 305 7.5 0 7.7 7.4 09/23/2005 00:40:00 8.6 0.8 10.7 6.1 7.5 0.9 9.9 5.3 250 7 259 305 7.5 0 7.7 7.4 09/23/2005 00:50:00 9.3 0.9 11.8 6.8 8.3 1 10.7 6.1 246 7 239 305 7.5 0 7.7 7.4 09/23/2005 01:00:00 9.7 1 12.2 6.8 8.7 1.2 11.5 5.3 242 6 238 305 7.6 0 7.7 7.4 09/23/2005 01:10:00 9.5 0.8 11.1 7.2 8.7 0.9 11.1 6.1 239 5 232 305 7.5 0 7.7 7.4 09/23/2005 01:20:00 9.4 0.8 11.1 6.8 8.6 0.8 10.7 6.5 239 5 239 305 7.5 0 7.9 7.4 09/23/2005 01:30:00 8.5 0.6 10.3 6.5 7.7 0.7 9.9 5.7 236 6 236 305 7.5 0 7.7 7.4 09/23/2005 01:40:00 8.2 0.7 9.9 6.1 7.5 0.7 9.5 6.1 236 6 229 305 7.5 0 7.7 7.4 09/23/2005 01:50:00 8 0.7 9.5 6.1 7.1 0.8 8.8 4.9 234 5 235 305 7.5 0 7.7 7.4 09/23/2005 02:00:00 7.8 0.7 9.1 5.7 7 0.8 8.8 5.3 234 6 238 305 7.5 0 7.7 7.4 09/23/2005 02:10:00 7.6 0.6 9.1 5.7 6.9 0.7 8.8 5.3 228 6 233 305 7.5 0 7.7 7.4 09/23/2005 02:20:00 7.3 0.6 8.8 5.3 6.5 0.6 8.4 4.9 222 6 221 305 7.3 0 7.4 7.2 09/23/2005 02:30:00 6.9 0.6 8.8 5.3 6.3 0.6 7.6 4.2 221 5 222 305 7.3 0 7.4 7.2 09/23/2005 02:40:00 7 0.6 8.4 5.3 6.4 0.6 7.6 4.9 222 5 221 305 7.3 0 7.4 7.2 09/23/2005 02:50:00 7.3 0.5 8.4 5.7 6.8 0.6 8 5.3 219 5 225 305 7.3 0 7.4 7.2 09/23/2005 03:00:00 6.6 0.6 8.4 4.6 6.1 0.7 8.4 4.2 214 6 221 305 7.3 0 7.4 7.2 09/23/2005 03:10:00 6.6 0.6 8.4 5.3 6.1 0.6 7.6 4.2 219 6 230 305 7.2 0 7.4 7.2 09/23/2005 03:20:00 7.3 0.7 9.1 4.9 6.5 0.8 8.4 4.6 223 5 224 305 7.3 0 7.4 7.2 09/23/2005 03:30:00 7.7 0.6 8.8 5.7 7.1 0.7 8.8 5.3 219 6 218 305 7.3 0 7.4 7.2 09/23/2005 03:40:00 8 0.6 9.5 6.5 7.5 0.7 9.1 5.3 215 4 210 305 7.5 0 7.7 7.4 09/23/2005 03:50:00 7.8 0.8 9.5 6.1 7 0.8 8.8 4.6 220 5 222 305 7.6 0 7.7 7.4 09/23/2005 04:00:00 8.2 0.6 9.5 6.5 7.5 0.7 9.1 6.1 224 5 224 305 7.6 0 7.7 7.7 09/23/2005 04:10:00 8.4 0.7 10.7 6.1 7.7 0.9 9.9 5.3 227 5 233 305 7.7 0 7.7 7.7 09/23/2005 04:20:00 8.8 0.7 10.3 6.5 8.2 0.7 9.9 6.1 228 5 232 305 7.7 0 7.9 7.7 09/23/2005 04:30:00 8.7 0.8 10.7 6.5 8.1 0.8 10.3 6.1 229 5 230 305 7.8 0 7.9 7.7 09/23/2005 04:40:00 8.4 0.7 10.3 6.5 7.7 0.7 9.5 5.7 229 5 233 305 7.7 0 7.9 7.7 09/23/2005 04:50:00 8.3 0.7 9.9 6.1 7.8 0.7 9.5 5.7 229 5 227 305 7.7 0 7.9 7.7 09/23/2005 05:00:00 7.8 0.8 9.5 5.3 6.9 0.8 8.8 5.3 232 6 238 305 7.6 0 7.9 7.4 09/23/2005 05:10:00 8 0.6 9.5 6.1 7.2 0.7 8.8 4.9 234 5 232 305 7.5 0 7.7 7.4 09/23/2005 05:20:00 7.2 0.8 9.5 4.9 6.6 0.8 8.4 4.6 229 6 227 305 7.5 0 7.7 7.4 09/23/2005 05:30:00 8.3 0.7 10.3 6.1 7.5 0.8 9.5 5.3 226 5 229 305 7.5 0 7.7 7.4 09/23/2005 05:40:00 8.8 0.6 10.7 6.8 8.4 0.7 9.9 6.1 227 5 226 305 7.3 0 7.7 7.2 09/23/2005 05:50:00 8.7 0.7 10.3 6.5 7.9 0.8 9.9 5.3 226 5 227 305 7.5 0 7.7 7.4 09/23/2005 06:00:00 8.4 0.6 9.9 6.8 7.9 0.7 9.9 5.7 228 5 225 305 7.5 0 7.7 7.4 09/23/2005 06:10:00 8 0.6 9.5 6.5 7.5 0.7 9.1 5.7 227 5 231 305 7.4 0 7.7 7.4 09/23/2005 06:20:00 7.5 0.5 9.1 5.7 7.1 0.6 8.8 5.7 228 5 227 305 7.3 0 7.7 7.4 09/23/2005 06:30:00 7.6 0.7 9.1 5.7 6.9 0.7 8.8 4.9 231 5 228 305 7.3 0 7.4 7.4 09/23/2005 06:40:00 8 0.6 9.1 6.1 7.3 0.6 8.8 5.7 230 5 236 305 7.3 0 7.4 7.2 09/23/2005 06:50:00 8 0.8 9.5 5.7 7.3 0.8 8.8 5.3 230 6 234 305 7.3 0 7.4 7.2 09/23/2005 07:00:00 8.6 0.8 10.3 6.5 7.7 0.9 9.5 5.3 232 6 237 305 7.3 0 7.4 7.2 09/23/2005 07:10:00 8.9 1 11.5 6.1 8 1 11.1 5.7 231 6 228 305 7.3 0 7.4 7.2 09/23/2005 07:20:00 9.1 0.9 11.5 6.8 8.2 1 11.1 6.1 234 7 242 305 7.3 0 7.4 7.2 09/23/2005 07:30:00 8.8 1.3 12.2 6.1 8 1.3 11.8 5.3 233 8 232 305 7.2 0 7.7 7.2 09/23/2005 07:40:00 9.2 0.7 10.7 7.2 8.6 0.9 10.7 6.1 226 5 231 305 7.2 0 7.4 7.2 09/23/2005 07:50:00 9.5 0.7 11.1 6.5 8.9 0.8 10.7 6.5 226 5 217 305 7.2 0 7.4 7.2 09/23/2005 08:00:00 9.4 1.2 12.6 6.1 8.5 1.1 11.8 4.9 226 7 230 305 7.2 0 7.4 7.2 09/23/2005 08:10:00 10 0.9 11.8 7.2 9 1 11.8 6.8 222 5 221 305 7.2 0 7.4 7.2 09/23/2005 08:20:00 10.5 0.7 12.2 8.4 9.6 1 11.8 7.2 221 5 217 305 7.2 0 7.4 7.2 09/23/2005 08:30:00 10.3 1 12.6 7.2 9.3 1 12.2 7.2 218 5 221 305 7.2 0 7.4 7.2 09/23/2005 08:40:00 10.7 0.7 12.6 8.8 10 0.8 11.8 8 216 5 214 305 7.2 0 7.4 7.2 09/23/2005 08:50:00 10.2 0.8 11.8 8 9.4 0.9 11.5 6.8 217 5 225 305 7.2 0 7.4 7.2 09/23/2005 09:00:00 10.1 0.8 12.2 8 9.4 0.9 11.5 7.2 217 5 217 305 7.2 0 7.4 7.2 09/23/2005 09:10:00 10.6 0.8 12.6 7.6 10 1 12.6 7.2 215 4 218 305 7.2 0 7.4 7.2 09/23/2005 09:20:00 10.6 0.9 12.2 7.6 9.8 1 11.8 7.6 215 5 211 305 7.2 0 7.4 7.2 09/23/2005 09:30:00 10.6 0.9 12.6 8.4 9.8 1 11.8 7.6 217 5 223 305 7.2 0 7.4 7.2 09/23/2005 09:40:00 10.7 0.7 13 8.8 10 0.8 11.8 7.6 215 5 220 305 7.3 0 7.4 7.2 09/23/2005 09:50:00 10.7 0.7 12.2 8.8 9.9 1 11.8 7.2 213 4 212 305 7.2 0 7.4 7.2 09/23/2005 10:00:00 10.3 0.8 11.8 8 9.6 1 11.5 6.8 217 5 213 305 7.2 0 7.4 7.2 09/23/2005 10:10:00 10 0.8 12.2 7.6 9.3 0.9 11.8 6.8 217 5 218 305 7.3 0 7.4 7.2 09/23/2005 10:20:00 9.9 0.8 12.2 7.6 9.2 0.9 12.2 7.2 217 5 220 305 7.3 0 7.4 7.2 09/23/2005 10:30:00 10.4 0.7 11.8 7.6 9.7 0.8 11.8 6.8 214 4 213 305 7.3 0 7.4 7.2 09/23/2005 10:40:00 9.7 0.9 11.5 6.8 9.2 0.9 11.1 6.8 215 5 213 305 7.2 0 7.4 7.2 09/23/2005 10:50:00 10.7 0.8 12.6 8.4 10.1 0.9 12.2 7.2 214 4 214 305 7.2 0 7.4 7.2 09/23/2005 11:00:00 10.6 0.9 13.3 8 9.7 1 12.2 7.2 220 6 213 305 7.2 0 7.4 7.2 09/23/2005 11:10:00 10.2 1.1 12.6 7.6 9.4 1.1 12.6 6.5 219 5 220 305 7.2 0 7.4 7.2 09/23/2005 11:20:00 10.3 1 12.2 7.2 9.6 1 11.5 7.2 220 6 214 305 7.2 0 7.4 7.2 09/23/2005 11:30:00 10.6 0.8 13 8 9.6 1 12.6 6.8 220 5 205 305 7.2 0 7.4 7.2 09/23/2005 11:40:00 10.3 0.8 12.2 7.2 9.4 1 11.8 6.5 219 5 221 305 7.3 0 7.4 7.2 09/23/2005 11:50:00 10.5 0.8 12.6 8 9.6 1 11.8 7.2 223 5 227 305 7.3 0 7.4 7.2 09/23/2005 12:00:00 10.7 1.1 13 6.8 9.9 1.1 12.2 6.8 227 5 227 305 7.3 0 7.4 7.2 09/23/2005 12:10:00 10.2 1.1 13 7.2 9.5 1.2 12.2 6.8 228 6 228 305 7.2 0 7.4 7.2 09/23/2005 12:20:00 9.9 0.8 11.8 7.2 9 1 11.5 6.5 224 6 215 305 7.2 0 7.4 7.2 09/23/2005 12:30:00 10.2 1 13 7.6 9.4 1.1 13 6.5 221 6 219 305 7.3 0 7.4 7.2 09/23/2005 12:40:00 10.1 1 12.6 7.6 9.3 1 12.2 7.2 218 5 224 305 7.3 0 7.4 7.2 09/23/2005 12:50:00 10.1 0.8 12.6 8 9.4 1 11.8 6.8 215 5 221 305 7.3 0 7.4 7.2 09/23/2005 13:00:00 10 0.9 12.6 7.6 9.2 1 12.2 6.8 218 5 220 305 7.3 0 7.4 7.4 09/23/2005 13:10:00 9.3 1 11.5 6.5 8.5 1 11.1 6.5 219 5 228 305 7.3 0 7.4 7.2 09/23/2005 13:20:00 9.3 0.8 11.1 6.8 8.6 0.8 10.7 6.5 218 5 221 305 7.3 0 7.4 7.2 09/23/2005 13:30:00 8.9 0.8 10.7 6.5 8.3 0.7 10.7 6.5 218 5 218 305 7.2 0 7.4 7.2 09/23/2005 13:40:00 9.1 0.6 11.1 7.2 8.7 0.7 10.3 5.7 216 4 220 305 7.3 0 7.4 7.2 09/23/2005 13:50:00 8.9 0.6 10.7 6.5 8.5 0.7 9.9 6.1 215 4 217 305 7.4 0 7.7 7.4 09/23/2005 14:00:00 8.7 0.7 10.3 6.5 8.1 0.8 9.9 5.7 217 5 220 305 7.5 0 7.7 7.4 09/23/2005 14:10:00 8.3 0.6 9.5 6.5 7.8 0.7 9.5 5.7 216 5 213 305 7.5 0 7.9 7.4 09/23/2005 14:20:00 8.9 0.7 10.7 6.8 8.4 0.7 10.3 6.8 216 5 219 305 7.6 0 8.2 7.7 09/23/2005 14:30:00 9.2 0.7 10.7 6.8 8.8 0.8 10.7 6.5 216 4 224 305 7.6 0 8.2 7.7 09/23/2005 14:40:00 8.9 0.7 10.3 6.8 8.3 0.7 10.3 6.1 216 5 213 305 7.7 0.1 8.2 7.7 09/23/2005 14:50:00 8.6 0.7 10.7 6.5 8.1 0.8 10.3 5.7 216 5 213 305 7.7 0 8.2 7.7 09/23/2005 15:00:00 8.8 0.6 10.3 6.8 8.4 0.8 9.9 5.7 213 4 212 305 7.9 0 8.4 7.7 09/23/2005 15:10:00 8.8 0.6 10.3 7.2 8.4 0.7 9.9 6.5 214 4 211 305 8 0 8.4 7.9 09/23/2005 15:20:00 8.8 0.7 10.7 6.1 8.2 0.9 9.9 6.1 216 5 215 305 8 0 8.7 7.9 09/23/2005 15:30:00 8.1 0.8 9.9 5.7 7.6 0.8 9.5 5.7 221 5 221 305 7.9 0 8.4 7.7 09/23/2005 15:40:00 8.9 0.9 10.7 5.7 8.3 1 10.3 5.7 220 5 220 305 7.7 0.1 8.2 7.7 09/23/2005 15:50:00 9.1 0.8 10.7 6.5 8.5 0.9 10.3 6.5 215 6 211 305 7.5 0.1 8.2 7.2 09/23/2005 16:00:00 9.2 0.7 11.1 6.8 8.5 0.9 11.1 6.1 208 5 210 305 7.3 0.1 7.9 7.2 09/23/2005 16:10:00 8.8 0.5 10.3 7.2 8.5 0.7 9.9 6.5 203 4 200 305 7.1 0 7.7 7.2 09/23/2005 16:20:00 7.5 1 9.1 4.9 7.3 1 9.1 4.6 205 7 200 305 7.1 0.1 7.7 7.2 09/23/2005 16:30:00 7.8 0.7 9.1 5.7 7.4 0.8 9.1 5.3 214 5 214 305 7.2 0.1 7.7 7.2 09/23/2005 16:40:00 7.5 0.9 9.1 4.9 7.3 0.9 9.1 4.9 205 5 202 305 7.2 0 7.7 7.2 09/23/2005 16:50:00 7.5 0.7 9.1 5.3 7.3 0.7 9.1 4.9 205 4 208 305 7.2 0 7.4 7.2 09/23/2005 17:00:00 6.5 0.6 7.6 4.6 6.1 0.6 7.6 4.2 210 6 217 305 7.3 0 7.4 7.2 09/23/2005 17:10:00 5.7 0.7 7.2 3.8 5.5 0.8 7.2 3.8 224 9 211 305 7.3 0 7.7 7.2 09/23/2005 17:20:00 4.2 0.5 5.3 2.6 4.1 0.5 4.9 2.6 232 6 230 305 7.2 0 7.4 7.2 09/23/2005 17:30:00 3.8 0.4 4.6 2.6 3.8 0.5 4.9 3 226 5 221 305 7 0 7.2 7.2 09/23/2005 17:40:00 3.9 0.5 4.9 2.6 3.8 0.5 4.9 2.6 227 6 230 305 7 0 7.2 7.2 09/23/2005 17:50:00 4.2 0.5 5.3 3 4.1 0.5 5.3 3 227 5 228 305 7 0 7.2 7.2 09/23/2005 18:00:00 4.4 0.4 5.3 3 4.3 0.5 5.3 3 223 5 225 305 7.1 0 7.2 7.2 09/23/2005 18:10:00 4.2 0.4 5.3 2.6 4 0.5 5.3 2.6 218 5 223 305 7.2 0 7.4 7.2 09/23/2005 18:20:00 4.5 0.4 5.7 3 4.3 0.5 5.3 3 220 6 232 305 7.5 0 7.7 7.4 09/23/2005 18:30:00 4.5 0.5 5.7 3.4 4.2 0.4 5.3 3 224 6 229 305 7.9 0.1 8.2 7.7 09/23/2005 18:40:00 4.6 0.4 5.7 3.4 4.3 0.5 5.7 3 226 5 221 305 7.9 0.1 8.2 7.7 09/23/2005 18:50:00 4.5 0.4 5.3 3.4 4.2 0.4 5.3 3.4 231 5 229 305 7.5 0 7.7 7.7 09/23/2005 19:00:00 4.6 0.3 5.3 3.4 4.2 0.4 5.3 3 226 5 227 305 7.6 0 8.2 7.7 09/23/2005 19:10:00 4.4 0.4 5.3 3 4.2 0.4 5.3 3 219 5 221 305 7.6 0 7.9 7.7 09/23/2005 19:20:00 5.1 0.4 6.1 3.8 4.8 0.4 5.7 3.4 217 4 218 305 7.6 0 8.2 7.4 09/23/2005 19:30:00 5.5 0.4 6.5 4.6 5.1 0.5 6.5 3.8 212 5 214 305 7.6 0 7.9 7.4 09/23/2005 19:40:00 5.8 0.5 6.8 4.2 5.4 0.6 6.8 3.8 212 5 215 305 7.6 0 8.2 7.7 09/23/2005 19:50:00 6.1 0.4 7.2 4.9 5.8 0.4 6.5 4.2 217 5 222 305 7.6 0 8.2 7.4 09/23/2005 20:00:00 6.7 0.6 8.4 4.9 6.1 0.7 8.4 4.6 220 5 234 305 7.6 0 7.9 7.4 09/23/2005 20:10:00 7 0.6 8.8 4.9 6.4 0.7 8.4 4.9 223 5 229 305 7.6 0 7.9 7.4 09/23/2005 20:20:00 7.3 0.7 8.8 5.7 6.8 0.7 8.4 4.9 232 8 231 305 7.5 0 7.9 7.4 09/23/2005 20:30:00 7.1 0.7 8.8 5.7 6.6 0.7 8.8 4.9 236 6 240 305 7.5 0 7.9 7.4 09/23/2005 20:40:00 7.4 0.9 9.5 5.3 6.8 1 9.1 4.6 239 5 242 305 7.3 0 7.9 7.2 09/23/2005 20:50:00 6.8 0.5 8 5.3 6.1 0.6 7.6 4.6 231 6 234 305 7.3 0 7.7 7.2 09/23/2005 21:00:00 6.5 0.6 8 4.6 6 0.6 7.6 4.6 230 6 225 305 7.3 0 7.7 7.2 09/23/2005 21:10:00 6.2 0.7 7.6 3.4 5.8 0.6 7.2 4.6 231 5 229 305 7.3 0 7.9 7.2 09/23/2005 21:20:00 6.3 0.5 8 4.6 5.9 0.6 7.2 4.2 232 5 231 305 7.3 0 7.7 7.2 09/23/2005 21:30:00 6.9 0.6 8.4 5.3 6.3 0.8 8 4.2 236 6 246 305 7.3 0 7.9 7.2 09/23/2005 21:40:00 6.4 0.6 8 4.6 5.6 0.6 7.2 4.2 232 6 244 305 7.3 0 7.4 7.2 09/23/2005 21:50:00 6.3 0.6 8 4.6 5.6 0.6 7.2 4.2 233 5 238 305 7.3 0 7.9 7.2 09/23/2005 22:00:00 6.9 0.6 8.4 5.3 6.2 0.7 8 4.6 234 5 236 305 7.3 0 7.4 7.4 09/23/2005 22:10:00 6.5 0.6 8 4.9 6 0.6 7.6 4.2 235 6 234 305 7.3 0 7.4 7.4 09/23/2005 22:20:00 6.9 0.6 8 5.3 6.3 0.6 7.6 4.6 234 6 231 305 7.3 0 7.9 7.4 09/23/2005 22:30:00 6.7 0.6 8 4.9 6.1 0.7 7.6 4.2 232 5 234 305 7.3 0 7.4 7.4 09/23/2005 22:40:00 6.8 0.6 8 5.3 6.1 0.7 7.6 4.2 234 5 234 305 7.3 0 7.4 7.4 09/23/2005 22:50:00 6.8 0.5 8 5.3 6.2 0.5 8 4.9 234 5 238 305 7.4 0 7.7 7.4 09/23/2005 23:00:00 6.5 0.6 7.6 4.9 6 0.6 7.6 4.6 235 6 236 305 7.3 0 7.4 7.4 09/23/2005 23:10:00 6.3 0.7 7.6 4.6 5.8 0.6 7.6 4.2 234 6 231 305 7.3 0 7.7 7.4 09/23/2005 23:20:00 6.5 0.6 7.6 4.2 5.9 0.6 7.6 3.8 237 6 239 305 7.3 0 7.4 7.4 09/23/2005 23:30:00 6.5 0.6 7.6 4.9 5.9 0.6 7.6 4.6 237 5 228 305 7.3 0.1 7.9 7.4 09/23/2005 23:40:00 6.6 0.6 8.4 4.9 5.9 0.6 7.6 4.2 239 6 234 305 7.3 0 7.9 7.4 09/23/2005 23:50:00 6.4 0.5 8.4 4.6 5.9 0.6 7.2 4.2 238 5 228 305 7.3 0 7.9 7.4 09/24/2005 00:00:00 6.2 0.6 7.6 4.6 5.5 0.7 7.6 3.8 244 7 243 305 7.3 0 7.9 7.2 09/24/2005 00:10:00 5.9 0.7 8 4.2 5.3 0.7 7.2 3.4 248 7 254 305 7.3 0 7.9 7.4 09/24/2005 00:20:00 6.2 0.7 8 4.2 5.5 0.7 7.6 3.8 249 6 267 305 7.3 0 7.9 7.4 09/24/2005 00:30:00 5.8 0.7 7.2 3.8 5.2 0.7 7.2 3 251 6 239 305 7.3 0 7.9 7.4 09/24/2005 00:40:00 6.2 0.7 7.6 4.2 5.3 0.7 7.2 3 254 7 255 305 7.3 0 7.9 7.4 09/24/2005 00:50:00 5.7 0.6 7.6 4.2 4.8 0.6 6.5 3 257 7 265 305 7.3 0 7.9 7.4 09/24/2005 01:00:00 5.9 0.7 8 4.2 4.5 0.7 6.5 3 266 7 275 305 7.3 0.1 7.9 7.2 09/24/2005 01:10:00 5.6 0.8 7.2 2.6 4.6 0.7 6.5 3 261 8 264 305 7.3 0 7.9 7.4 09/24/2005 01:20:00 5.6 0.9 7.6 3 4.5 1 6.8 2.3 270 10 259 305 7.3 0 7.7 7.2 09/24/2005 01:30:00 5.8 0.8 8 3.8 4.6 1 6.8 2.3 269 7 275 305 7.3 0.1 7.9 7.4 09/24/2005 01:40:00 5.1 0.6 6.8 3 4.1 0.6 6.1 2.6 262 7 264 305 7.3 0 7.9 7.2 09/24/2005 01:50:00 5.5 0.9 8 3 4.3 0.8 6.5 1.9 262 8 262 305 7.3 0 7.9 7.2 09/24/2005 02:00:00 6.8 0.6 8.4 4.9 5.4 0.6 6.8 3.4 263 7 245 305 7.4 0 7.9 7.4 09/24/2005 02:10:00 6.5 0.7 8 4.6 5.5 0.6 7.2 3.8 256 5 261 305 7.5 0 7.9 7.4 09/24/2005 02:20:00 5.6 0.5 6.8 4.2 5.2 0.6 6.5 3 249 6 258 305 7.4 0 7.9 7.4 09/24/2005 02:30:00 5.5 0.6 6.8 4.2 5.1 0.7 6.8 3.4 247 8 242 305 7.3 0 7.7 7.4 09/24/2005 02:40:00 7.5 1.2 10.3 3.8 6.2 1 9.1 3.4 256 7 264 305 7.3 0 7.9 7.4 09/24/2005 02:50:00 9.1 0.8 11.1 6.5 7.7 1 10.7 4.2 254 6 258 305 7.3 0 7.4 7.4 09/24/2005 03:00:00 9.1 0.9 11.1 6.5 7.6 1 11.1 4.6 255 6 255 305 7.3 0.1 7.7 7.2 09/24/2005 03:10:00 8.1 0.9 9.9 5.7 6.7 0.9 9.1 4.2 255 6 243 305 7.2 0.1 7.7 7.2 09/24/2005 03:20:00 8.4 0.8 10.3 6.1 7.1 0.9 9.5 4.2 254 6 251 305 7.1 0 7.7 7.2 09/24/2005 03:30:00 8.3 0.9 9.9 5.7 7.2 1 10.3 4.9 253 6 254 305 7 0 7.2 6.9 09/24/2005 03:40:00 8.2 0.8 10.7 5.3 7.3 1.1 9.9 3.8 251 5 249 305 7 0 7.7 6.9 09/24/2005 03:50:00 7.5 1 9.5 4.9 6.8 1 9.5 4.2 247 6 249 305 7 0 7.2 6.9 09/24/2005 04:00:00 8.1 0.8 9.9 5.3 7.5 1 9.1 4.9 245 6 238 305 7.1 0.1 7.7 7.2 09/24/2005 04:10:00 8.6 1 11.1 5.3 8 1 10.7 4.6 247 7 252 305 6.8 0.2 7.7 6.7 09/24/2005 04:20:00 7.9 0.7 9.9 5.7 7.3 1 9.1 4.6 243 6 250 305 6.7 0 7.2 6.7 09/24/2005 04:30:00 8.4 0.9 10.7 6.1 7.6 1 10.3 4.9 242 6 242 305 6.8 0.1 7.2 6.7 09/24/2005 04:40:00 7.9 1.1 10.3 4.6 7.4 1.2 10.3 4.2 246 6 247 305 6.6 0 7.2 6.4 09/24/2005 04:50:00 7.8 0.9 9.9 5.7 7.2 1.1 9.5 4.6 241 5 244 305 6.5 0 7.2 6.4 09/24/2005 05:00:00 8 0.7 9.5 5.3 7.2 1 9.1 4.2 250 8 251 305 6.5 0 6.9 6.4 09/24/2005 05:10:00 6.8 0.8 8.4 4.9 6 0.9 8.8 4.2 251 6 244 305 6.5 0 6.4 6.4 09/24/2005 05:20:00 6.6 0.7 8 4.6 6 0.8 8 3.8 245 6 258 305 6.5 0 7.2 6.4 09/24/2005 05:30:00 6.9 0.9 8.8 4.6 6.5 1 8.4 3.8 245 7 251 305 6.6 0.1 7.2 6.4 09/24/2005 05:40:00 7 0.8 8.8 4.9 6.5 1 8.4 3.8 249 7 247 305 6.6 0 7.2 6.4 09/24/2005 05:50:00 7.5 0.7 8.8 5.3 7.1 0.8 8.4 4.6 242 5 246 305 6.6 0.1 7.2 6.4 09/24/2005 06:00:00 7.6 0.7 9.1 5.3 7 0.8 9.1 4.6 239 5 238 305 6.6 0 7.2 6.4 09/24/2005 06:10:00 7.2 1 9.1 4.6 6.7 1 8.8 4.6 239 5 239 305 6.5 0 7.2 6.4 09/24/2005 06:20:00 7.2 0.8 9.1 5.3 6.7 1 8.8 4.6 239 6 237 305 6.6 0 7.2 6.4 09/24/2005 06:30:00 7.4 0.8 8.8 4.9 7 0.8 8.4 4.6 237 5 233 305 6.7 0 6.9 6.4 09/24/2005 06:40:00 7.2 0.8 8.8 4.6 6.5 1.2 8.8 3.8 249 9 240 305 6.6 0 7.2 6.1 09/24/2005 06:50:00 6.1 0.6 7.2 4.2 5.6 0.9 7.2 3 249 8 263 305 6.4 0 6.4 6.1 09/24/2005 07:00:00 5.7 0.6 7.2 4.2 5.3 0.6 6.8 3.8 245 6 247 305 6.5 0 6.4 6.4 09/24/2005 07:10:00 5.5 0.6 6.8 4.2 5.1 0.8 6.8 3 249 7 247 305 6.5 0 6.7 6.4 09/24/2005 07:20:00 5.3 0.7 6.8 3.4 4.7 0.8 6.5 2.6 248 6 252 305 6.5 0 6.7 6.4 09/24/2005 07:30:00 5.3 0.6 6.8 3.8 4.9 0.7 6.8 2.6 246 7 250 305 6.6 0 6.7 6.4 09/24/2005 07:40:00 6.2 0.8 8.4 3.8 5.9 0.8 7.6 3.4 237 5 235 305 6.6 0 6.9 6.4 09/24/2005 07:50:00 5.2 0.7 7.2 3.4 4.9 0.6 6.5 3.4 232 5 232 305 6.5 0 6.4 6.4 09/24/2005 08:00:00 5.2 0.6 6.5 3.4 5 0.6 6.1 3.4 238 6 238 305 6.5 0 7.2 6.4 09/24/2005 08:10:00 6.3 1 8.8 4.2 6 1 8.4 3.8 237 5 234 305 6.7 0 7.2 6.4 09/24/2005 08:20:00 6.8 1 10.3 4.2 5.7 1.3 10.3 3 256 11 238 305 6.5 0 7.2 6.1 09/24/2005 08:30:00 5.4 0.6 6.8 3.4 4.8 0.7 6.8 3 250 7 261 305 6.3 0 6.9 6.1 09/24/2005 08:40:00 5.3 0.5 6.8 3.8 5.1 0.6 6.8 3.4 240 5 244 305 6.5 0 6.4 6.4 09/24/2005 08:50:00 5.1 0.5 6.1 3.8 4.8 0.5 6.1 3.4 242 5 239 305 6.5 0 7.2 6.4 09/24/2005 09:00:00 5.1 0.5 6.5 3.4 4.8 0.6 6.8 3.4 239 6 232 305 6.7 0 7.2 6.4 09/24/2005 09:10:00 4.8 0.5 6.1 3.4 4.7 0.6 5.7 3 245 6 256 305 6.8 0 7.2 6.7 09/24/2005 09:20:00 5.2 0.7 6.8 3.4 4.7 0.8 6.8 3 251 5 256 305 6.8 0 7.2 6.7 09/24/2005 09:30:00 4.8 0.6 6.5 3.4 4.3 0.8 6.1 2.6 248 7 238 305 6.8 0 7.4 6.7 09/24/2005 09:40:00 5.6 0.8 7.2 3.8 4.9 0.8 7.2 2.6 252 7 250 305 6.9 0 7.4 6.9 09/24/2005 09:50:00 5.5 0.8 6.8 3.4 4.7 0.8 6.5 2.6 257 7 247 305 6.7 0.1 7.4 6.7 09/24/2005 10:00:00 5.8 0.6 7.2 3.8 5.2 0.7 6.8 3.4 252 7 269 305 6.6 0.1 7.2 6.4 09/24/2005 10:10:00 5.2 0.8 7.2 3 4.7 0.9 6.8 2.6 254 11 256 305 6.6 0.1 7.2 6.4 09/24/2005 10:20:00 4 0.5 5.3 2.6 3.4 0.6 4.9 1.9 266 7 268 305 6.5 0 7.2 6.4 09/24/2005 10:30:00 3.6 0.5 4.6 1.9 3.1 0.5 4.6 1.9 256 5 256 305 6.5 0.1 7.2 6.4 09/24/2005 10:40:00 3.7 0.7 5.3 1.9 3 0.6 4.2 1.5 265 8 259 305 6.5 0 7.2 6.4 09/24/2005 10:50:00 3.1 0.6 4.6 1.5 2.6 0.6 4.2 1.1 265 11 275 305 6.5 0 7.2 6.4 09/24/2005 11:00:00 2.9 0.4 3.8 1.5 2.6 0.5 3.8 1.5 267 15 258 305 6.5 0 7.2 6.4 09/24/2005 11:10:00 2.4 0.3 3 1.9 2.5 0.3 3.4 1.9 289 9 288 305 6.3 0 6.9 6.1 09/24/2005 11:20:00 1.8 0.4 2.6 0.7 2 0.4 3 0.7 290 7 300 305 6.3 0 6.9 6.1 09/24/2005 11:30:00 2.3 0.3 3 1.5 2.5 0.3 3 1.5 294 11 305 305 6.3 0 6.4 6.1 09/24/2005 11:40:00 2.5 0.3 3.4 1.9 2.7 0.3 3.4 1.9 302 14 291 305 6.3 0 6.9 6.1 09/24/2005 11:50:00 3.6 0.4 4.6 2.3 3.9 0.5 4.9 2.6 314 8 308 305 6.2 0 6.4 5.9 09/24/2005 12:00:00 3 0.6 4.2 1.5 3.4 0.6 4.6 1.9 321 5 320 305 6 0 6.7 5.6 09/24/2005 12:10:00 2.4 0.5 3.4 1.1 2.7 0.4 3.8 1.9 325 6 319 305 5.9 0 6.4 5.9 09/24/2005 12:20:00 2.1 0.5 3.4 1.1 2.6 0.4 3.4 1.9 329 9 324 305 6 0 6.7 5.9 09/24/2005 12:30:00 2.5 0.4 3.4 1.1 2.9 0.4 4.2 1.9 323 8 326 305 6.1 0 6.4 5.9 09/24/2005 12:40:00 1.8 0.6 3 0.4 2.2 0.5 3.4 0.7 316 9 327 305 6 0.1 6.7 5.9 09/24/2005 12:50:00 1.4 0.6 2.6 0.4 1.8 0.5 3.4 0.7 317 12 316 305 6.2 0 6.4 6.1 09/24/2005 13:00:00 1.5 0.7 3 0.4 1.9 0.6 3 0.4 315 13 311 305 6.3 0 6.9 6.1 09/24/2005 13:10:00 2 0.6 3.4 0.4 2.3 0.5 3.8 0.7 299 11 296 305 6.5 0.1 7.2 6.4 09/24/2005 13:20:00 3 0.3 3.8 2.3 3.2 0.3 4.2 2.6 302 15 303 305 6.5 0.1 7.2 6.4 09/24/2005 13:30:00 3.3 0.4 4.6 2.3 3.4 0.4 4.6 2.6 296 13 308 305 6.5 0.1 7.2 6.4 09/24/2005 13:40:00 3.5 0.5 4.9 1.5 3.6 0.5 4.6 1.9 298 15 305 305 6.7 0.1 7.2 6.4 09/24/2005 13:50:00 3.9 0.3 4.9 3 4.2 0.4 4.9 3.4 306 20 296 305 6.6 0.1 7.2 6.4 09/24/2005 14:00:00 4.2 0.5 5.3 3 4.4 0.5 5.7 3 299 10 286 305 6.7 0.1 7.2 6.4 09/24/2005 14:10:00 4.5 0.5 5.3 3 4.6 0.5 5.7 3.4 299 17 306 305 6.4 0 7.2 6.1 09/24/2005 14:20:00 4.4 0.5 5.7 3 4.6 0.5 5.7 3 312 16 302 305 6.1 0.1 6.7 5.9 09/24/2005 14:30:00 4.6 0.4 5.3 3.4 4.8 0.4 5.7 3.4 309 18 312 305 6 0.1 6.7 5.9 09/24/2005 14:40:00 4.5 0.4 5.3 3.4 4.6 0.4 5.7 3.4 311 17 305 305 5.8 0 6.4 5.6 09/24/2005 14:50:00 4.6 0.4 5.3 3 4.7 0.4 5.7 3.4 308 16 308 305 5.8 0 6.1 5.6 09/24/2005 15:00:00 4.6 0.4 5.3 3.8 4.7 0.4 5.7 3.8 308 19 308 305 5.7 0.1 6.4 5.4 09/24/2005 15:10:00 4.6 0.4 5.7 3.4 4.8 0.5 5.7 3.8 308 22 307 305 5.5 0 5.6 5.4 09/24/2005 15:20:00 4.6 0.5 5.7 3.4 4.8 0.5 5.7 3.8 309 18 303 305 5.5 0 5.6 5.4 09/24/2005 15:30:00 4.6 0.5 5.7 3 4.8 0.5 5.7 3.4 309 15 304 305 5.5 0 5.6 5.4 09/24/2005 15:40:00 4.8 0.4 5.7 3.8 5 0.4 6.1 3.8 311 19 305 305 5.4 0 5.6 5.4 09/24/2005 15:50:00 4.5 0.4 5.3 3.4 4.7 0.4 5.3 3 310 18 304 305 5.6 0 5.9 5.4 09/24/2005 16:00:00 4.5 0.4 5.7 3.4 4.7 0.5 5.7 3.4 314 14 313 305 5.8 0 6.4 5.6 09/24/2005 16:10:00 4.9 0.4 6.1 3.8 5.1 0.4 6.1 4.2 312 17 310 305 6 0.1 6.4 5.9 09/24/2005 16:20:00 5.1 0.4 6.1 4.2 5.3 0.4 6.5 4.2 317 8 303 305 6.1 0.1 6.4 5.9 09/24/2005 16:30:00 5.3 0.4 6.1 4.2 5.5 0.4 6.1 4.2 314 8 311 305 6.3 0 6.4 6.1 09/24/2005 16:40:00 4.9 0.4 5.7 3.8 5.1 0.4 6.1 3.8 317 8 319 305 6.3 0 6.7 6.1 09/24/2005 16:50:00 5.1 0.4 5.7 3.4 5.3 0.4 6.1 4.2 319 5 319 305 6.5 0.1 6.9 6.1 09/24/2005 17:00:00 4.7 0.4 5.7 3.4 5 0.5 6.1 3.8 316 9 323 305 6.8 0.1 7.2 6.4 09/24/2005 17:10:00 5 0.4 6.1 3.8 5.2 0.4 6.1 3.8 309 17 305 305 7 0 7.2 6.9 09/24/2005 17:20:00 4.7 0.4 5.7 3.4 4.9 0.4 5.7 3.8 310 9 313 305 7 0 7.2 6.9 09/24/2005 17:30:00 4.7 0.4 5.7 3.4 4.9 0.5 6.1 3.8 311 13 306 305 6.8 0 7.2 6.9 09/24/2005 17:40:00 4.4 0.4 5.7 3 4.5 0.4 5.3 3.8 308 18 299 305 7 0 7.2 6.9 09/24/2005 17:50:00 4.6 0.4 5.7 3.4 4.8 0.4 5.7 3.8 307 8 13 305 7 0 7.2 6.9 09/24/2005 18:00:00 4.6 0.4 5.3 3.4 4.8 0.4 5.7 3.8 306 12 310 305 6.7 0 6.9 6.4 09/24/2005 18:10:00 4.2 0.5 5.3 2.6 4.4 0.5 5.7 3 307 10 308 305 6.3 0 6.7 6.1 09/24/2005 18:20:00 4.3 0.4 4.9 3 4.5 0.4 5.7 3.8 310 8 308 305 6.2 0 6.4 6.1 09/24/2005 18:30:00 3.8 0.4 4.6 2.6 4.1 0.4 4.9 3 314 9 359 305 6.1 0.1 6.4 5.9 09/24/2005 18:40:00 3.6 0.5 4.9 2.3 3.9 0.5 5.3 2.6 317 6 318 305 6.1 0.1 6.9 5.9 09/24/2005 18:50:00 4.3 0.4 5.3 3.4 4.6 0.4 5.7 3.4 317 5 311 305 6.1 0.1 6.9 5.9 09/24/2005 19:00:00 4.2 0.4 4.9 3 4.5 0.4 5.3 3 314 12 305 305 6.3 0.1 6.9 5.9 09/24/2005 19:10:00 4.4 0.4 5.3 3.4 4.6 0.4 5.3 3.4 315 8 309 305 6.3 0.1 6.9 6.1 09/24/2005 19:20:00 4.3 0.4 4.9 3.4 4.6 0.4 5.7 3.8 317 5 316 305 6.2 0.1 6.7 6.1 09/24/2005 19:30:00 4.4 0.3 4.9 3.8 4.7 0.3 5.3 3.8 315 5 305 305 6.1 0.1 6.7 5.9 09/24/2005 19:40:00 4.2 0.3 4.9 3.4 4.5 0.4 5.3 3.4 320 4 325 305 6.1 0.1 6.7 5.9 09/24/2005 19:50:00 4.1 0.3 4.9 3 4.4 0.4 5.3 3.4 319 5 312 305 6.1 0.1 6.4 5.9 09/24/2005 20:00:00 3.7 0.4 4.6 2.6 4 0.5 4.9 2.6 320 5 316 305 6 0 6.4 5.9 09/24/2005 20:10:00 3.1 0.4 4.2 2.3 3.5 0.4 4.6 2.3 331 4 325 305 6 0 6.4 5.9 09/24/2005 20:20:00 2.8 0.3 3.4 2.3 3.3 0.3 3.8 2.3 340 4 334 305 6 0 6.1 5.9 09/24/2005 20:30:00 2.7 0.2 3.4 2.3 3.2 0.2 3.8 2.6 342 4 339 305 6 0 6.1 5.9 09/24/2005 20:40:00 2.6 0.5 3.8 1.5 3 0.4 4.2 2.3 337 4 334 305 6 0 6.4 5.9 09/24/2005 20:50:00 2 0.3 2.6 1.1 2.5 0.3 3 1.9 336 8 337 305 6.1 0 6.7 5.9 09/24/2005 21:00:00 1.8 0.3 2.6 0.7 2.4 0.2 3 1.5 326 6 317 305 6.2 0 6.9 6.1 09/24/2005 21:10:00 2.2 0.4 3.4 1.5 2.7 0.3 3.8 1.9 328 5 340 305 6.2 0 6.7 6.1 09/24/2005 21:20:00 2.7 0.5 3.8 1.5 3.1 0.6 4.2 1.9 333 10 351 305 6.3 0 6.9 6.1 09/24/2005 21:30:00 2.7 0.3 3.4 2.3 3.1 0.3 3.8 2.3 349 6 340 305 6.3 0 6.9 6.1 09/24/2005 21:40:00 2.6 0.2 3 1.9 3 0.2 3.4 2.3 357 7 2 305 6.2 0 6.9 6.1 09/24/2005 21:50:00 2.5 0.3 3.4 1.9 2.9 0.3 3.8 2.3 358 5 351 305 6.1 0 6.7 5.9 09/24/2005 22:00:00 2.3 0.3 3 1.5 2.6 0.2 3 1.9 347 6 346 305 6.1 0 6.4 5.9 09/24/2005 22:10:00 2.2 0.4 3 1.1 2.7 0.3 3.4 1.9 347 4 345 305 6 0 6.7 5.9 09/24/2005 22:20:00 1.3 0.8 3.4 0.4 1.9 0.6 3.8 1.1 339 7 347 305 6.1 0 6.7 5.9 09/24/2005 22:30:00 2.8 0.3 3.8 1.9 3.1 0.2 3.8 2.6 335 5 324 305 6.1 0 6.4 6.1 09/24/2005 22:40:00 2.4 0.2 3 1.9 2.9 0.2 3.4 2.3 339 2 341 305 6.1 0 6.9 5.9 09/24/2005 22:50:00 2.9 0.3 3.4 1.9 3.3 0.3 3.8 2.6 335 5 339 305 6.1 0 6.1 5.9 09/24/2005 23:00:00 3.6 0.3 4.6 3 3.9 0.3 4.9 3 339 5 339 305 6.1 0 6.1 5.9 09/24/2005 23:10:00 3.5 0.4 4.2 2.3 3.8 0.5 4.9 2.6 328 6 330 305 6 0 6.1 5.9 09/24/2005 23:20:00 3.3 0.5 4.2 1.9 3.7 0.5 4.6 2.3 336 9 336 305 5.9 0 6.1 5.9 09/24/2005 23:30:00 2.9 0.4 3.8 1.9 3.3 0.4 4.2 1.9 341 8 325 305 5.8 0 5.9 5.6 09/24/2005 23:40:00 2.1 0.3 3 1.5 2.5 0.3 3.4 1.9 335 7 338 305 5.7 0 5.9 5.6 09/24/2005 23:50:00 2.7 0.4 3.4 1.5 3.1 0.4 3.8 2.3 336 5 330 305 5.8 0 5.9 5.6 09/25/2005 00:00:00 3.4 0.3 4.2 2.6 3.9 0.3 4.6 3.4 343 3 347 305 5.7 0 6.1 5.6 09/25/2005 00:10:00 2.8 0.4 3.8 2.3 3.3 0.3 4.2 2.6 342 4 342 305 5.6 0 5.9 5.6 09/25/2005 00:20:00 2.5 0.4 3.4 1.5 3 0.5 3.8 1.9 334 5 334 305 5.6 0 5.6 5.4 09/25/2005 00:30:00 2.8 0.3 3.4 1.9 3.2 0.3 3.8 2.3 333 6 331 305 5.6 0 5.6 5.6 09/25/2005 00:40:00 2.8 0.2 3.4 2.3 3.3 0.2 3.8 2.6 329 4 331 305 5.6 0 5.9 5.6 09/25/2005 00:50:00 2.6 0.3 3.4 1.9 2.9 0.3 3.4 2.3 335 4 332 305 5.6 0 5.9 5.6 09/25/2005 01:00:00 2.5 0.3 3 1.9 2.8 0.2 3.4 2.3 337 4 327 305 5.6 0 5.6 5.6 09/25/2005 01:10:00 2.6 0.3 3.4 1.9 2.9 0.3 3.8 2.3 338 4 337 305 5.6 0 5.9 5.6 09/25/2005 01:20:00 2.5 0.4 3.4 1.9 2.9 0.4 3.8 2.3 338 3 335 305 5.6 0 5.9 5.6 09/25/2005 01:30:00 2.5 0.2 3 1.9 2.9 0.2 3.4 2.3 343 5 343 305 5.7 0 5.9 5.6 09/25/2005 01:40:00 2 0.4 3 1.1 2.4 0.3 3 1.5 342 7 342 305 5.8 0 5.9 5.6 09/25/2005 01:50:00 2 0.3 2.6 1.1 2.4 0.3 3 1.9 339 5 348 305 5.7 0 5.9 5.6 09/25/2005 02:00:00 1.8 0.3 2.6 1.1 2.2 0.3 3 1.5 329 5 336 305 5.6 0 5.9 5.4 09/25/2005 02:10:00 1.6 0.6 2.6 0.4 2.1 0.4 3 1.1 318 6 315 305 5.6 0 5.6 5.6 09/25/2005 02:20:00 2.3 0.3 2.6 1.9 2.6 0.3 3 1.9 314 4 318 305 5.6 0 5.6 5.6 09/25/2005 02:30:00 2.3 0.2 2.6 1.5 2.6 0.2 3 2.3 318 3 323 305 5.6 0 5.9 5.6 09/25/2005 02:40:00 1.9 0.5 2.6 1.1 2.2 0.4 3 1.5 313 8 311 305 5.6 0 5.9 5.6 09/25/2005 02:50:00 2.1 0.3 2.6 1.5 2.5 0.2 3 1.9 325 6 317 305 5.8 0 5.9 5.6 09/25/2005 03:00:00 1.2 0.6 2.3 0.4 1.8 0.5 3 1.1 322 3 331 305 5.7 0 5.9 5.6 09/25/2005 03:10:00 0.9 0.3 1.5 0.4 1.5 0.3 1.9 0.7 321 9 331 305 5.7 0 5.9 5.6 09/25/2005 03:20:00 1.7 0.4 2.6 0.7 2 0.4 2.6 1.1 314 5 323 305 5.8 0 5.9 5.6 09/25/2005 03:30:00 1.8 0.2 2.6 1.1 2.2 0.2 2.6 1.5 318 4 322 305 5.8 0 5.9 5.6 09/25/2005 03:40:00 0.9 0.5 1.5 0.4 1.5 0.4 2.3 0.4 314 4 311 305 5.6 0 5.9 5.6 09/25/2005 03:50:00 0.5 0.2 1.1 0.4 1.3 0.2 1.9 0.7 317 7 320 305 5.6 0 5.9 5.6 09/25/2005 04:00:00 1.3 0.6 2.3 0.4 1.7 0.4 2.6 0.7 311 3 313 305 5.6 0 5.9 5.6 09/25/2005 04:10:00 1.9 0.3 2.6 1.1 2.3 0.3 3 1.5 312 6 313 305 5.6 0 5.9 5.6 09/25/2005 04:20:00 1.8 0.4 2.6 0.7 2.2 0.3 2.6 1.5 309 11 312 305 5.6 0 5.6 5.4 09/25/2005 04:30:00 1.9 0.4 2.6 0.7 2.2 0.4 3 1.1 309 10 305 305 5.5 0 5.6 5.4 09/25/2005 04:40:00 1.5 0.3 2.3 0.7 1.9 0.3 2.6 1.1 309 15 304 305 5.5 0 5.6 5.4 09/25/2005 04:50:00 0.9 0.4 1.9 0.4 1.5 0.3 1.9 0.7 306 2 305 305 5.6 0 5.6 5.4 09/25/2005 05:00:00 0.7 0.6 2.3 0.4 1.4 0.4 2.6 0.7 307 12 306 305 5.6 0 5.6 5.4 09/25/2005 05:10:00 1.4 0.4 2.3 0.4 1.8 0.4 2.6 1.1 316 6 309 305 5.8 0 5.9 5.6 09/25/2005 05:20:00 1.9 0.4 3 1.1 2.2 0.4 3.4 1.5 313 5 316 305 5.9 0 5.9 5.6 09/25/2005 05:30:00 2.2 0.4 3 1.5 2.5 0.3 3.4 1.9 313 5 320 305 5.8 0 5.9 5.6 09/25/2005 05:40:00 2.1 0.4 2.6 0.7 2.4 0.3 3 1.5 313 6 318 305 5.8 0 5.9 5.6 09/25/2005 05:50:00 2.2 0.3 3 1.5 2.4 0.3 3 1.9 309 12 309 305 5.8 0 5.9 5.6 09/25/2005 06:00:00 2.2 0.2 2.6 1.5 2.6 0.2 3 1.9 311 5 309 305 5.8 0 5.9 5.6 09/25/2005 06:10:00 2.3 0.3 3 1.5 2.6 0.3 3.4 1.9 320 5 323 305 5.8 0 5.9 5.6 09/25/2005 06:20:00 2.1 0.4 3 1.1 2.5 0.4 3 1.5 328 4 321 305 5.9 0 5.9 5.6 09/25/2005 06:30:00 2.3 0.3 3 1.5 2.6 0.3 3.4 1.5 327 4 323 305 5.9 0 5.9 5.6 09/25/2005 06:40:00 2.3 0.3 3 1.5 2.7 0.3 3.4 1.9 338 7 336 305 5.9 0 5.9 5.9 09/25/2005 06:50:00 2.5 0.4 3.4 1.9 2.9 0.4 4.2 2.3 351 4 345 305 5.9 0 5.9 5.9 09/25/2005 07:00:00 2.5 0.4 3.4 1.5 2.9 0.4 3.8 1.5 350 5 348 305 5.9 0 5.9 5.9 09/25/2005 07:10:00 2.6 0.3 3.4 1.9 3 0.3 3.8 2.3 352 5 358 305 6 0 6.1 5.9 09/25/2005 07:20:00 3 0.2 3.4 2.6 3.4 0.2 3.8 3 350 2 350 305 5.9 0 5.9 5.9 09/25/2005 07:30:00 2.9 0.3 3.4 2.3 3.3 0.3 4.2 2.6 352 4 355 305 5.8 0 5.9 5.6 09/25/2005 07:40:00 2.9 0.3 3.4 2.3 3.3 0.2 3.8 2.6 353 3 352 305 5.8 0 5.9 5.6 09/25/2005 07:50:00 3.1 0.3 3.4 2.3 3.5 0.3 3.8 2.3 351 3 347 305 5.6 0 5.9 5.6 09/25/2005 08:00:00 3.2 0.2 3.8 2.6 3.5 0.2 4.2 3 357 3 358 305 5.6 0 5.6 5.4 09/25/2005 08:10:00 2.9 0.3 3.8 2.3 3.3 0.4 4.2 2.3 353 3 347 305 5.5 0 5.6 5.4 09/25/2005 08:20:00 2.3 0.3 3 1.5 2.7 0.3 3.4 1.9 2 3 3 305 5.6 0 5.6 5.4 09/25/2005 08:30:00 2.2 0.2 2.6 1.5 2.6 0.3 3 1.9 356 4 359 305 5.6 0 5.9 5.6 09/25/2005 08:40:00 1.8 0.2 2.3 1.1 2.2 0.3 2.6 1.5 357 6 1 305 5.6 0 5.9 5.6 09/25/2005 08:50:00 1.7 0.5 2.3 0.4 2.2 0.4 3 1.1 356 6 4 305 5.7 0 5.9 5.6 09/25/2005 09:00:00 1.4 0.3 2.3 0.7 1.7 0.4 2.6 0.7 8 8 350 305 5.8 0 5.9 5.6 09/25/2005 09:10:00 0.4 0.2 1.1 0.4 0.8 0.2 1.5 0.4 21 9 13 305 5.8 0 5.9 5.6 09/25/2005 09:20:00 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 34 1 305 305 5.9 0 5.9 5.6 09/25/2005 09:30:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 29 10 305 305 5.9 0 5.9 5.9 09/25/2005 09:40:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 8 9 354 305 5.9 0 6.1 5.9 09/25/2005 09:50:00 0.9 0.2 1.5 0.4 1.2 0.2 1.5 0.4 353 2 355 305 6 0 6.1 5.9 09/25/2005 10:00:00 0.5 0.2 1.1 0.4 0.7 0.4 1.5 0.4 2 2 351 305 6 0 6.1 5.9 09/25/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 2 305 305 6 0 6.1 5.9 09/25/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 1 305 305 6.2 0 6.4 6.1 09/25/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 1 305 305 6.3 0 6.4 6.1 09/25/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 23 305 305 6.5 0 6.9 6.4 09/25/2005 10:50:00 0.4 0.1 0.7 0.4 0.6 0.2 1.1 0.4 309 5 312 305 6.5 0 6.7 6.4 09/25/2005 11:00:00 0.8 0.5 1.9 0.4 1 0.5 1.9 0.4 304 6 305 305 6.6 0.1 7.2 6.4 09/25/2005 11:10:00 1.6 0.4 2.3 0.7 1.8 0.5 2.6 0.7 324 21 319 305 6.5 0.1 7.2 6.4 09/25/2005 11:20:00 1.6 0.3 2.3 0.7 1.9 0.3 2.6 1.1 348 6 355 305 6.5 0 7.2 6.4 09/25/2005 11:30:00 1.3 0.3 2.3 0.4 1.8 0.2 2.3 1.1 345 4 345 305 6.5 0 6.7 6.4 09/25/2005 11:40:00 1 0.3 1.9 0.4 1.6 0.3 2.3 0.7 338 4 340 305 6.5 0.1 7.2 6.4 09/25/2005 11:50:00 1.3 0.4 2.3 0.4 1.8 0.3 2.6 1.1 342 6 336 305 6.5 0 6.7 6.4 09/25/2005 12:00:00 1.7 0.3 2.6 1.1 2.1 0.2 2.6 1.5 340 5 345 305 6.5 0 7.2 6.4 09/25/2005 12:10:00 1.6 0.3 2.3 1.1 1.9 0.3 2.6 1.5 343 5 340 305 6.5 0 7.2 6.4 09/25/2005 12:20:00 1.5 0.3 1.9 0.7 1.6 0.3 2.3 0.7 349 8 334 305 6.5 0 7.2 6.4 09/25/2005 12:30:00 1.2 0.4 2.3 0.4 1.4 0.3 1.9 0.7 353 7 350 305 6.7 0.1 7.2 6.4 09/25/2005 12:40:00 1.2 0.4 2.3 0.4 1.4 0.3 2.3 0.4 345 5 353 305 6.7 0.1 7.2 6.4 09/25/2005 12:50:00 0.8 0.4 1.9 0.4 1.1 0.3 1.9 0.4 350 1 350 305 6.7 0 7.2 6.7 09/25/2005 13:00:00 1.2 0.3 1.9 0.4 1.4 0.3 1.9 0.7 353 7 350 305 6.7 0 7.2 6.7 09/25/2005 13:10:00 2 1.1 4.6 0.4 2.1 1.1 4.6 0.4 354 7 354 305 6.8 0 7.4 6.7 09/25/2005 13:20:00 4.2 0.3 4.9 3.4 4.2 0.4 4.9 3.4 353 3 357 305 6.9 0 7.4 6.9 09/25/2005 13:30:00 4 0.3 4.6 3 4 0.4 4.9 2.6 355 3 355 305 6.8 0 7.4 6.7 09/25/2005 13:40:00 3.5 0.3 4.2 2.6 3.6 0.3 4.6 2.6 350 5 347 305 6.8 0 7.4 6.7 09/25/2005 13:50:00 3.4 0.2 3.8 2.6 3.5 0.3 4.2 2.6 344 4 337 305 6.9 0 7.4 6.9 09/25/2005 14:00:00 3.2 0.3 3.8 2.3 3.3 0.3 3.8 2.3 342 5 341 305 7 0.1 7.7 6.9 09/25/2005 14:10:00 3.1 0.3 4.2 2.3 3.4 0.4 4.2 2.6 343 5 343 305 7 0 7.4 6.9 09/25/2005 14:20:00 3.1 0.3 3.8 2.3 3.2 0.4 4.2 2.3 345 5 347 305 6.9 0 7.2 6.7 09/25/2005 14:30:00 2.7 0.4 3.8 1.9 2.9 0.4 4.2 1.9 349 5 341 305 6.8 0 6.9 6.7 09/25/2005 14:40:00 2.6 0.3 3.4 1.5 2.7 0.4 3.8 1.5 351 5 4 305 6.8 0 6.9 6.7 09/25/2005 14:50:00 2.4 0.3 3 1.5 2.5 0.3 3.4 1.5 351 6 357 305 6.7 0.1 7.2 6.4 09/25/2005 15:00:00 2.6 0.4 3.4 1.5 2.8 0.4 3.8 1.9 339 7 330 305 6.6 0 6.9 6.4 09/25/2005 15:10:00 2.1 0.4 3 1.1 2.3 0.4 3.4 1.5 353 8 351 305 6.5 0 6.7 6.4 09/25/2005 15:20:00 2.1 0.4 3 1.5 2.3 0.4 3.4 1.1 351 6 354 305 6.5 0 6.7 6.4 09/25/2005 15:30:00 2.3 0.3 3 1.5 2.5 0.3 3.4 1.5 351 5 355 305 6.7 0.1 6.9 6.4 09/25/2005 15:40:00 2.5 0.3 3.4 1.5 2.7 0.4 3.4 1.9 354 4 0 305 6.7 0 6.9 6.4 09/25/2005 15:50:00 2.5 0.3 3 1.5 2.6 0.3 3 1.9 352 5 353 305 6.7 0 6.9 6.7 09/25/2005 16:00:00 2.4 0.4 3 1.5 2.5 0.4 3.4 1.5 357 6 353 305 6.8 0 6.9 6.7 09/25/2005 16:10:00 2.3 0.3 3 1.5 2.5 0.3 3 1.5 353 7 359 305 6.7 0 6.9 6.7 09/25/2005 16:20:00 2.1 0.3 3 1.1 2.2 0.4 3 0.7 351 11 329 305 6.7 0 6.9 6.7 09/25/2005 16:30:00 2.4 0.3 3.4 1.5 2.5 0.4 3.4 1.5 346 8 323 305 6.8 0 7.4 6.7 09/25/2005 16:40:00 2 0.4 3 1.1 2.1 0.4 3 1.1 347 6 351 305 6.8 0.1 7.4 6.7 09/25/2005 16:50:00 2.2 0.4 3 1.1 2.3 0.4 3 1.5 354 5 355 305 6.8 0.1 7.4 6.7 09/25/2005 17:00:00 1.8 0.4 3 0.7 1.9 0.4 3.4 1.1 359 7 355 305 6.8 0 7.4 6.7 09/25/2005 17:10:00 2.4 0.2 3 1.9 2.5 0.3 3 1.9 346 4 350 305 6.9 0 7.4 6.9 09/25/2005 17:20:00 1.8 0.5 3 0.4 1.9 0.5 3 0.7 347 10 343 305 6.9 0 7.4 6.9 09/25/2005 17:30:00 1.9 0.3 2.6 1.1 2 0.4 3 0.7 348 10 342 305 6.9 0 7.4 6.7 09/25/2005 17:40:00 2.1 0.5 3.4 1.1 2.2 0.5 3.4 1.1 340 12 328 305 6.8 0.1 7.4 6.7 09/25/2005 17:50:00 1.6 0.6 3 0.4 1.8 0.6 3 0.4 332 7 320 305 6.8 0.1 7.4 6.7 09/25/2005 18:00:00 1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 340 13 347 305 6.8 0 7.2 6.7 09/25/2005 18:10:00 1.7 0.4 2.6 0.4 1.9 0.4 2.6 0.4 328 18 340 305 6.8 0 7.4 6.7 09/25/2005 18:20:00 1.3 0.4 2.3 0.4 1.3 0.4 2.3 0.4 310 10 312 305 6.8 0 7.2 6.7 09/25/2005 18:30:00 1.7 0.4 2.6 0.4 1.8 0.3 3 1.1 321 24 312 305 6.9 0 7.4 6.9 09/25/2005 18:40:00 1.1 0.6 2.3 0.4 1.2 0.7 2.6 0.4 336 21 323 305 6.8 0 7.2 6.7 09/25/2005 18:50:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 324 45 10 305 6.7 0 6.9 6.7 09/25/2005 19:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 283 18 284 305 6.7 0 7.2 6.7 09/25/2005 19:10:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 296 23 228 305 6.7 0 6.9 6.7 09/25/2005 19:20:00 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 243 16 227 305 6.7 0 6.9 6.4 09/25/2005 19:30:00 1.1 0.5 2.3 0.4 1.1 0.4 1.9 0.4 250 6 256 305 6.6 0 6.7 6.4 09/25/2005 19:40:00 1.4 0.4 2.3 0.4 1.1 0.4 1.9 0.4 260 7 270 305 6.6 0 6.9 6.4 09/25/2005 19:50:00 1.4 0.3 2.3 0.7 1.4 0.3 1.9 0.7 243 6 255 305 6.5 0 6.7 6.4 09/25/2005 20:00:00 1.6 0.3 2.3 1.1 1.5 0.3 1.9 0.7 237 7 245 305 6.5 0 7.2 6.1 09/25/2005 20:10:00 2 0.3 2.6 1.1 1.9 0.3 2.6 1.1 233 6 234 305 6.5 0 6.9 6.1 09/25/2005 20:20:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 0.7 234 9 246 305 6.4 0 6.4 6.1 09/25/2005 20:30:00 2 0.3 2.6 1.1 1.8 0.3 2.6 1.1 222 9 231 305 6.4 0 6.4 6.1 09/25/2005 20:40:00 2.2 0.2 2.6 1.5 2.2 0.3 2.6 1.5 221 3 219 305 6.4 0 6.4 6.1 09/25/2005 20:50:00 2 0.4 3 1.1 1.9 0.3 3.4 1.1 223 6 231 305 6.4 0 6.4 6.1 09/25/2005 21:00:00 2.1 0.4 3 1.1 1.9 0.5 3 0.7 230 11 224 305 6.5 0 6.4 6.4 09/25/2005 21:10:00 2.1 0.3 3 1.5 2 0.3 3 1.1 224 6 226 305 6.5 0 6.7 6.4 09/25/2005 21:20:00 1.8 0.4 2.6 1.1 1.7 0.4 2.6 0.7 213 4 213 305 6.5 0 6.4 6.4 09/25/2005 21:30:00 2.1 0.4 3 1.1 2 0.4 3 1.1 210 6 213 305 6.5 0 6.7 6.4 09/25/2005 21:40:00 2.1 0.3 3 1.5 2 0.3 2.6 1.5 222 6 227 305 6.5 0 6.7 6.4 09/25/2005 21:50:00 1.8 0.3 2.6 1.1 1.7 0.3 2.3 1.1 215 6 224 305 6.6 0 6.9 6.4 09/25/2005 22:00:00 2.2 0.3 3 1.5 2.1 0.3 2.6 1.5 214 5 213 305 6.6 0 6.7 6.4 09/25/2005 22:10:00 2.4 0.3 3 1.5 2.4 0.3 3 1.5 214 5 210 305 6.6 0 6.7 6.4 09/25/2005 22:20:00 2.5 0.3 3 1.5 2.3 0.3 3 1.5 213 5 214 305 6.6 0 6.9 6.4 09/25/2005 22:30:00 2.4 0.3 3 1.5 2.2 0.3 3 1.5 210 6 216 305 6.7 0 6.9 6.7 09/25/2005 22:40:00 2.4 0.4 3.4 1.5 2.2 0.4 3 0.7 207 9 214 305 6.7 0 6.9 6.7 09/25/2005 22:50:00 2.3 0.4 3.4 1.1 2.3 0.4 3.4 1.1 198 9 193 305 6.7 0 6.9 6.7 09/25/2005 23:00:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.5 199 8 194 305 6.7 0 6.9 6.7 09/25/2005 23:10:00 2 0.5 3 0.7 1.9 0.5 3 0.7 221 6 203 305 6.6 0 6.9 6.4 09/25/2005 23:20:00 1.8 0.5 2.6 0.7 1.5 0.4 2.3 0.4 227 9 235 305 6.6 0 6.9 6.4 09/25/2005 23:30:00 2.4 0.3 3 1.1 2.1 0.3 2.6 1.1 224 10 227 305 6.7 0 6.9 6.4 09/25/2005 23:40:00 2.4 0.4 3.4 1.1 2.3 0.4 3.4 1.5 202 9 192 305 6.7 0 6.9 6.4 09/25/2005 23:50:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 206 7 199 305 6.6 0 6.7 6.4 09/26/2005 00:00:00 2.9 0.3 3.8 2.3 2.8 0.3 3.4 1.9 206 7 201 305 6.5 0 7.2 6.4 09/26/2005 00:10:00 2.5 0.4 3 1.1 2.4 0.4 3 1.5 208 8 204 305 6.6 0 6.7 6.4 09/26/2005 00:20:00 2.1 0.4 3 1.1 2.1 0.3 3 1.1 209 8 218 305 6.6 0 6.9 6.4 09/26/2005 00:30:00 2.9 0.4 3.8 1.5 2.9 0.4 3.8 1.9 195 7 192 305 6.5 0 6.7 6.4 09/26/2005 00:40:00 2.8 0.3 3.4 1.9 2.8 0.2 3.4 2.3 186 3 186 305 6.4 0 6.4 6.1 09/26/2005 00:50:00 2.7 0.4 3.4 1.5 2.8 0.3 3.4 1.9 185 4 183 305 6.3 0 6.4 6.1 09/26/2005 01:00:00 2.7 0.3 3.4 1.5 2.5 0.4 3.4 1.5 197 7 202 305 6.3 0 6.4 6.1 09/26/2005 01:10:00 3 0.4 3.8 1.9 3 0.4 4.2 1.9 191 6 188 305 6.4 0 6.4 6.1 09/26/2005 01:20:00 1.8 0.6 3 0.7 2.3 0.4 3 1.5 181 6 184 305 6.4 0 6.4 6.1 09/26/2005 01:30:00 1.5 0.5 2.6 0.7 1.9 0.4 2.6 0.7 179 5 178 305 6.2 0.1 6.4 5.9 09/26/2005 01:40:00 1.9 0.3 2.6 0.7 2.4 0.3 3 1.5 181 4 187 305 5.8 0 5.9 5.6 09/26/2005 01:50:00 2.2 0.5 3.8 1.1 3.3 0.3 3.8 2.6 175 6 184 305 5.6 0 5.9 5.4 09/26/2005 02:00:00 2.5 0.5 3.4 1.5 2.9 0.4 3.8 1.9 183 8 194 305 5.6 0 5.9 5.4 09/26/2005 02:10:00 2.8 0.4 3.8 1.5 3.1 0.5 4.2 1.9 185 7 184 305 5.9 0 5.9 5.6 09/26/2005 02:20:00 2.3 0.4 3.4 1.1 2.6 0.3 3.4 1.5 183 5 182 305 5.9 0 5.9 5.9 09/26/2005 02:30:00 2.2 0.4 3 1.1 2.5 0.3 3.4 1.9 182 4 187 305 6 0 6.1 5.9 09/26/2005 02:40:00 2.4 0.3 3 1.5 2.5 0.3 3 1.9 187 3 188 305 6 0 6.1 5.9 09/26/2005 02:50:00 2.6 0.4 3.4 1.5 3.1 0.4 4.2 2.3 180 5 186 305 6 0 6.1 5.9 09/26/2005 03:00:00 3 0.8 5.3 1.9 4.2 0.3 4.9 3.4 166 6 155 305 6 0 6.1 5.9 09/26/2005 03:10:00 4.7 0.5 6.1 3 4.8 0.4 5.7 3.8 158 3 157 305 6.1 0 6.1 5.9 09/26/2005 03:20:00 3.2 0.8 5.3 1.5 4.1 0.5 5.3 3 168 7 159 305 6.1 0 6.1 5.9 09/26/2005 03:30:00 3 0.7 4.6 1.5 3.5 0.4 4.6 2.3 162 7 155 305 6.1 0 6.4 5.9 09/26/2005 03:40:00 3.6 0.6 5.3 2.3 4.4 0.5 5.3 2.6 163 6 158 305 6.1 0 6.1 5.9 09/26/2005 03:50:00 3.5 0.6 5.3 2.3 4.7 0.5 6.1 2.6 170 7 158 305 6.1 0 6.4 5.9 09/26/2005 04:00:00 4.3 0.7 5.7 2.3 4.7 0.5 5.7 3.4 183 5 190 305 6.4 0 6.4 6.1 09/26/2005 04:10:00 5.1 0.5 6.5 3 5.3 0.4 6.5 4.6 188 5 192 305 6.5 0 6.7 6.4 09/26/2005 04:20:00 4.6 0.4 5.3 3.4 4.7 0.5 5.7 3 194 6 188 305 6.5 0 6.7 6.4 09/26/2005 04:30:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3 195 6 198 305 6.4 0 6.4 6.1 09/26/2005 04:40:00 4 0.2 4.6 3.4 4.1 0.3 4.6 3.4 191 3 190 305 6.4 0 6.4 6.1 09/26/2005 04:50:00 4.1 0.4 4.9 2.6 4.1 0.4 4.9 3 189 3 186 305 6.3 0 6.4 6.1 09/26/2005 05:00:00 4.5 0.4 5.7 3.4 4.6 0.4 5.7 3.8 187 3 184 305 6.4 0 6.4 6.1 09/26/2005 05:10:00 4.6 0.6 5.7 2.6 5 0.4 5.7 4.2 184 4 183 305 6.4 0 6.4 6.1 09/26/2005 05:20:00 4.5 0.5 5.7 2.6 4.7 0.4 5.7 3.8 186 5 189 305 6.5 0 6.4 6.4 09/26/2005 05:30:00 4 0.5 5.3 3 4.1 0.5 5.3 3 191 5 188 305 6.4 0 6.4 6.1 09/26/2005 05:40:00 3.1 0.6 4.2 1.1 3.3 0.4 4.2 1.9 185 12 198 305 6.4 0 6.4 6.1 09/26/2005 05:50:00 2.2 0.4 3.4 1.1 3.2 0.4 4.6 2.3 171 7 179 305 6.1 0.1 6.4 5.9 09/26/2005 06:00:00 2.6 0.5 4.2 1.9 3.7 0.4 4.9 2.3 169 7 172 305 5.9 0 6.1 5.9 09/26/2005 06:10:00 3 0.6 4.9 1.5 3.9 0.4 4.9 3 166 7 158 305 5.8 0.1 5.9 5.4 09/26/2005 06:20:00 2.6 0.4 3.8 1.5 4.2 0.3 4.9 3.4 168 4 167 305 5.2 0.1 5.4 4.9 09/26/2005 06:30:00 3.3 0.7 4.6 1.9 4.1 0.3 4.9 3.4 162 5 157 305 5 0 5.2 4.9 09/26/2005 06:40:00 5 0.6 6.5 3 4.9 0.5 6.1 3.8 150 6 154 305 5.2 0 5.4 4.9 09/26/2005 06:50:00 3.6 1.3 5.7 1.5 4.5 0.6 5.7 3.4 162 9 149 305 5.3 0 5.6 5.2 09/26/2005 07:00:00 3.3 1 4.9 1.5 4 0.3 4.9 3 161 6 158 305 5.3 0.1 5.6 4.9 09/26/2005 07:10:00 3.5 0.8 5.7 2.3 4.6 0.4 5.3 3.4 166 8 155 305 5.3 0.1 5.6 5.2 09/26/2005 07:20:00 2.8 0.6 4.2 1.5 4.1 0.5 5.3 3 171 6 172 305 5.6 0 5.9 5.4 09/26/2005 07:30:00 5.1 0.4 5.7 3.4 5.1 0.4 5.7 3 145 5 155 305 5.1 0.2 5.6 4.7 09/26/2005 07:40:00 4.9 0.3 5.7 3.8 4.8 0.4 5.3 3.8 135 4 140 305 4.8 0.2 5.4 4.7 09/26/2005 07:50:00 4.7 0.4 5.3 3.4 4.6 0.4 5.7 3.4 135 5 129 305 5.5 0.1 5.9 5.4 09/26/2005 08:00:00 4.3 0.5 5.3 3 4.1 0.5 4.9 2.6 137 7 137 305 5.5 0 5.6 5.4 09/26/2005 08:10:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 2.3 125 9 133 305 5.7 0 5.9 5.6 09/26/2005 08:20:00 3.5 0.5 4.9 2.3 3.4 0.5 4.6 2.3 121 10 110 305 5.8 0 5.9 5.6 09/26/2005 08:30:00 3.7 0.6 4.9 1.9 3.7 0.6 5.7 1.5 121 11 116 305 5.9 0 5.9 5.6 09/26/2005 08:40:00 3.7 0.5 5.7 2.3 3.6 0.6 5.3 2.3 123 11 118 305 6 0 6.1 5.9 09/26/2005 08:50:00 3.9 0.7 5.3 2.3 3.8 0.6 5.3 2.3 128 10 127 305 6.1 0 6.1 5.9 09/26/2005 09:00:00 4.1 0.7 5.7 2.3 4.1 0.7 5.7 2.3 124 10 126 305 6.1 0 6.1 5.9 09/26/2005 09:10:00 4.6 0.8 6.5 2.6 4.5 0.8 6.5 2.3 125 12 134 305 6.2 0 6.4 6.1 09/26/2005 09:20:00 4.1 1 6.8 2.3 4 0.9 6.5 2.3 131 14 141 305 6.3 0 6.4 6.1 09/26/2005 09:30:00 5.7 0.8 7.2 3.4 5.7 0.7 7.6 3.8 133 8 144 305 6.3 0 6.4 6.1 09/26/2005 09:40:00 5.1 0.8 7.2 3.4 5 0.8 6.8 3.4 132 10 136 305 6.3 0 6.4 6.1 09/26/2005 09:50:00 3.5 1 6.5 1.5 3.6 1 6.8 1.9 129 15 152 305 6.5 0 6.4 6.1 09/26/2005 10:00:00 4.9 0.8 6.8 2.3 4.8 0.7 6.5 3 119 13 121 305 6.5 0 6.7 6.4 09/26/2005 10:10:00 5 0.7 6.8 3 5 0.7 6.5 3.4 130 13 118 305 6.4 0 6.4 6.1 09/26/2005 10:20:00 5.8 0.7 7.2 3.8 5.7 0.6 6.8 4.2 133 7 136 305 6.5 0 6.7 6.1 09/26/2005 10:30:00 5.7 0.6 6.8 4.2 5.6 0.6 7.2 3.4 135 6 137 305 6.6 0 6.7 6.4 09/26/2005 10:40:00 5.7 0.6 6.8 4.2 5.7 0.5 6.8 4.6 138 5 138 305 6.7 0 6.9 6.4 09/26/2005 10:50:00 5.5 0.6 7.2 4.2 5.4 0.5 7.6 4.2 138 7 145 305 6.7 0 7.2 6.7 09/26/2005 11:00:00 5.5 0.6 6.8 3.8 5.4 0.6 6.8 4.2 137 7 129 305 6.8 0 6.9 6.7 09/26/2005 11:10:00 4.9 0.7 6.8 2.6 4.9 0.6 6.8 3 142 10 131 305 7 0 7.2 6.9 09/26/2005 11:20:00 4.1 0.6 5.7 2.6 4 0.6 5.7 2.6 139 11 148 305 7 0 7.2 6.9 09/26/2005 11:30:00 3.9 0.6 5.3 2.6 3.8 0.5 5.3 2.6 128 8 128 305 7 0 7.2 7.2 09/26/2005 11:40:00 3 0.6 4.6 1.5 2.9 0.5 4.2 1.9 125 14 131 305 7 0 7.2 7.2 09/26/2005 11:50:00 2.5 0.7 3.8 0.4 2.4 0.6 3.8 0.7 121 16 108 305 7.2 0 7.4 7.2 09/26/2005 12:00:00 3 0.8 4.9 1.5 2.8 0.7 4.9 1.1 124 20 120 305 7.4 0 7.7 7.4 09/26/2005 12:10:00 3.7 0.9 6.1 1.5 3.8 0.9 6.1 1.9 130 15 107 305 7.5 0 7.7 7.4 09/26/2005 12:20:00 3.8 1 6.5 1.5 3.8 0.9 5.7 1.5 142 20 152 305 7.5 0 7.7 7.4 09/26/2005 12:30:00 5.1 1.3 7.6 1.9 5.2 1.2 7.6 2.3 150 10 156 305 7.9 0 8.2 7.7 09/26/2005 12:40:00 4.9 1 7.2 2.6 5.5 0.9 7.6 3.8 164 16 189 305 8 0 8.2 7.9 09/26/2005 12:50:00 5.4 1.1 8 2.6 5.6 0.8 7.6 3.4 154 14 157 305 8.2 0 8.4 7.9 09/26/2005 13:00:00 5.9 0.8 8 3.8 5.9 0.7 7.6 3.8 144 9 143 305 8.2 0 8.4 7.9 09/26/2005 13:10:00 6.2 1 8.8 4.2 6.2 1 8 3.8 146 9 143 305 7.9 0 8.2 7.7 09/26/2005 13:20:00 6.9 0.9 9.1 4.6 6.8 0.8 8.8 4.9 149 9 154 305 7.9 0 7.9 7.7 09/26/2005 13:30:00 5.9 0.7 7.6 3.8 5.9 0.7 7.6 4.2 145 9 140 305 7.8 0 7.9 7.7 09/26/2005 13:40:00 6.3 0.7 8 4.2 6.2 0.6 8 4.2 148 7 147 305 7.8 0 7.9 7.7 09/26/2005 13:50:00 5.8 0.8 8 3.4 5.7 0.7 7.2 3.8 145 8 149 305 7.9 0 8.2 7.9 09/26/2005 14:00:00 6.2 0.8 7.6 4.2 6.1 0.7 7.6 4.2 133 6 138 305 8 0 8.2 7.9 09/26/2005 14:10:00 6.1 0.5 7.2 4.9 6 0.5 7.2 4.6 134 5 130 305 8 0 8.2 7.9 09/26/2005 14:20:00 6.7 0.9 8.8 4.6 6.6 0.9 8.8 4.9 133 6 133 305 7.7 0 7.9 7.7 09/26/2005 14:30:00 7.4 0.7 9.1 4.9 7.3 0.7 9.1 4.6 141 8 143 305 7.4 0 7.7 7.2 09/26/2005 14:40:00 5.8 1.3 9.1 2.6 5.8 1.1 9.1 3 152 11 156 305 7.2 0 7.4 7.2 09/26/2005 14:50:00 4.1 0.8 6.5 2.3 5 0.8 6.5 2.6 175 8 155 305 7.5 0.1 7.7 7.4 09/26/2005 15:00:00 3.6 0.9 5.3 1.1 3.7 0.7 4.9 2.3 138 16 130 305 7.8 0 7.9 7.7 09/26/2005 15:10:00 4 1.2 8.4 2.3 4.1 1.2 8.4 1.9 125 22 144 305 8 0 8.2 7.7 09/26/2005 15:20:00 4.9 0.7 6.5 3 4.8 0.7 6.5 3.4 133 11 146 305 8 0 8.2 7.7 09/26/2005 15:30:00 4 1.5 6.8 0.4 4 1.3 6.8 0.4 126 18 150 305 8.2 0 8.2 8.2 09/26/2005 15:40:00 4.5 1 6.8 2.3 4.4 0.8 6.1 2.6 138 16 142 305 8.2 0 8.4 8.2 09/26/2005 15:50:00 5.3 0.6 6.8 3.8 5.2 0.6 7.2 3.8 138 9 145 305 8.2 0 8.4 8.2 09/26/2005 16:00:00 4.6 0.6 6.1 2.6 4.6 0.7 6.1 3 134 8 140 305 8.2 0 8.4 8.2 09/26/2005 16:10:00 4.1 0.8 6.1 2.3 4.1 0.9 6.1 1.5 135 15 133 305 8.1 0 8.2 7.9 09/26/2005 16:20:00 3.6 1.1 6.1 0.4 3.7 0.9 6.1 1.9 133 17 142 305 8 0 8.2 7.9 09/26/2005 16:30:00 3.3 0.8 5.3 0.7 3.2 0.8 5.3 0.4 134 17 148 305 8 0 8.2 7.9 09/26/2005 16:40:00 4 0.9 6.5 2.3 4 0.9 6.1 1.9 141 15 152 305 8.1 0 8.2 7.9 09/26/2005 16:50:00 3.6 0.8 5.7 1.9 3.5 0.8 5.7 1.9 125 16 112 305 8.1 0 8.2 7.9 09/26/2005 17:00:00 3.7 0.7 4.9 1.9 3.6 0.7 5.3 1.9 120 23 139 305 8 0 8.2 7.9 09/26/2005 17:10:00 3.4 0.9 5.7 0.7 3.3 0.9 5.7 0.7 110 21 107 305 8 0 8.2 7.9 09/26/2005 17:20:00 4.5 1 6.5 1.9 4.3 1 6.5 2.3 126 13 122 305 8 0 8.2 7.7 09/26/2005 17:30:00 5.2 0.6 6.5 3.4 5 0.6 6.1 3.4 137 7 146 305 7.9 0 7.9 7.7 09/26/2005 17:40:00 4.3 0.6 5.3 2.6 4.1 0.6 5.3 2.6 136 6 139 305 7.9 0 7.9 7.7 09/26/2005 17:50:00 4.1 0.8 6.5 2.3 4 0.9 6.1 2.3 133 13 149 305 7.8 0 7.9 7.7 09/26/2005 18:00:00 3.8 0.9 6.1 1.9 3.8 0.8 6.8 1.9 114 22 153 305 7.4 0 7.7 7.2 09/26/2005 18:10:00 4.7 0.8 6.5 3 4.5 0.7 6.8 2.6 124 17 147 305 7.3 0 7.4 7.2 09/26/2005 18:20:00 3.6 1 5.3 0.7 3.6 1 5.7 1.1 123 20 125 305 7.3 0 7.4 7.4 09/26/2005 18:30:00 2.9 0.7 4.6 1.1 2.9 0.7 4.9 1.5 102 17 128 305 7.2 0 7.4 7.2 09/26/2005 18:40:00 2.6 0.7 4.6 0.4 2.6 0.8 4.2 0.7 85 19 81 305 7.2 0 7.4 7.2 09/26/2005 18:50:00 3.2 1.2 5.7 1.1 3 1.3 5.7 0.7 83 20 62 305 7 0 7.2 7.2 09/26/2005 19:00:00 4.3 0.4 5.7 3 4.2 0.4 5.3 3 74 5 77 305 7 0 7.2 6.9 09/26/2005 19:10:00 4.7 0.5 5.7 3.4 4.5 0.4 5.3 3.4 75 6 78 305 7 0 7.2 6.9 09/26/2005 19:20:00 5.3 0.4 6.5 4.2 5.2 0.3 6.1 4.2 71 3 66 305 6.8 0 6.9 6.9 09/26/2005 19:30:00 4.9 0.4 6.1 4.2 4.7 0.4 5.7 4.2 70 5 86 305 6.8 0 6.9 6.9 09/26/2005 19:40:00 4.4 0.3 5.3 3.8 4.3 0.3 5.3 3.4 67 5 63 305 6.8 0 6.9 6.9 09/26/2005 19:50:00 4.4 0.4 5.3 3.4 4.2 0.4 4.9 3.4 63 4 64 305 6.8 0 7.2 6.7 09/26/2005 20:00:00 4.3 0.3 4.9 3.4 4.2 0.3 4.9 3 59 5 62 305 6.8 0 7.4 6.7 09/26/2005 20:10:00 4.9 0.4 5.7 4.2 4.7 0.4 5.7 3.8 56 4 58 305 6.9 0 7.4 6.9 09/26/2005 20:20:00 5.3 0.7 7.2 4.2 5.1 0.6 6.8 3.8 58 8 67 305 6.9 0 7.4 6.9 09/26/2005 20:30:00 7 0.6 8.4 5.7 6.7 0.6 8 5.3 72 5 65 305 6.8 0 7.4 6.9 09/26/2005 20:40:00 6.7 0.5 8 4.9 6.4 0.5 7.6 4.9 72 5 71 305 6.8 0.1 7.4 6.7 09/26/2005 20:50:00 7 0.4 8 5.7 6.7 0.4 7.6 5.3 70 3 69 305 6.8 0.2 7.4 6.7 09/26/2005 21:00:00 6.8 0.4 7.6 5.7 6.5 0.4 7.6 5.3 70 3 66 305 6.7 0.1 7.2 6.4 09/26/2005 21:10:00 6.7 0.4 7.6 5.7 6.4 0.5 7.6 5.3 68 3 66 305 6.6 0.1 7.2 6.4 09/26/2005 21:20:00 7.1 0.5 8.4 6.1 6.8 0.5 8 5.7 69 3 68 305 6.5 0 6.9 6.4 09/26/2005 21:30:00 7.3 0.5 8.4 6.1 7 0.5 8.4 5.3 71 3 67 305 6.5 0 6.9 6.4 09/26/2005 21:40:00 7.5 0.5 8.8 6.1 7.2 0.5 8 5.7 68 4 68 305 6.5 0 6.9 6.4 09/26/2005 21:50:00 7.1 0.5 8 6.1 6.9 0.5 8 5.3 64 3 67 305 6.5 0.1 6.9 6.1 09/26/2005 22:00:00 6.6 0.4 7.2 5.7 6.3 0.4 7.2 4.9 59 3 54 305 6.4 0 7.2 6.1 09/26/2005 22:10:00 7.1 0.4 8 6.1 6.9 0.4 8 6.1 56 3 56 305 6.5 0 6.4 6.1 09/26/2005 22:20:00 7 0.5 8 5.7 6.8 0.5 8 5.3 56 3 58 305 6.5 0 6.4 6.4 09/26/2005 22:30:00 6.9 0.4 8 6.1 6.6 0.4 7.6 5.3 59 3 62 305 6.5 0 6.7 6.4 09/26/2005 22:40:00 6.9 0.4 8 5.7 6.7 0.4 8 5.3 54 3 57 305 6.6 0 6.9 6.4 09/26/2005 22:50:00 7.6 0.4 8.4 6.1 7.5 0.4 8.4 6.1 54 3 52 305 6.7 0 6.9 6.7 09/26/2005 23:00:00 7.7 0.6 9.1 6.5 7.5 0.6 8.8 6.1 62 5 68 305 6.7 0 7.2 6.4 09/26/2005 23:10:00 6.8 0.4 7.6 5.7 6.5 0.4 7.6 5.3 57 4 62 305 6.5 0 7.2 6.4 09/26/2005 23:20:00 7.5 0.4 8.4 6.5 7.2 0.5 8.4 5.7 53 3 57 305 6.6 0 6.9 6.7 09/26/2005 23:30:00 7.6 0.4 8.4 6.5 7.4 0.4 8.4 6.1 48 3 50 305 6.6 0 7.2 6.4 09/26/2005 23:40:00 7.6 0.5 8.8 6.1 7.4 0.5 8.4 6.1 51 3 51 305 6.6 0 7.2 6.4 09/26/2005 23:50:00 7.6 0.6 8.8 6.1 7.4 0.7 8.8 5.7 50 5 48 305 6.5 0 6.7 6.1 09/27/2005 00:00:00 7.6 0.5 8.8 6.1 7.5 0.6 8.8 5.7 46 4 44 305 6.4 0 7.2 6.1 09/27/2005 00:10:00 7.4 0.4 8.4 5.7 7.3 0.4 8.4 6.1 39 3 40 305 6.3 0 6.4 6.1 09/27/2005 00:20:00 6.3 0.6 7.2 4.9 6.2 0.6 7.2 4.9 36 6 36 305 6.3 0 6.9 6.1 09/27/2005 00:30:00 6.3 1 9.1 4.6 6.2 1 8.8 4.6 41 7 46 305 6.5 0.1 7.2 6.1 09/27/2005 00:40:00 8.6 0.5 9.9 7.2 8.4 0.6 9.9 6.8 52 3 50 305 6.8 0.1 7.4 6.4 09/27/2005 00:50:00 9 0.6 10.3 7.2 8.7 0.7 10.3 6.5 53 3 51 305 6.9 0 7.4 6.9 09/27/2005 01:00:00 8.7 0.6 9.9 6.8 8.5 0.6 9.9 6.5 53 3 57 305 6.9 0 7.4 6.9 09/27/2005 01:10:00 8.2 0.6 9.5 6.5 8 0.6 9.5 6.5 52 3 46 305 6.9 0 7.4 6.9 09/27/2005 01:20:00 8 0.5 9.5 6.8 7.8 0.5 9.1 6.5 50 4 55 305 6.9 0 7.4 6.9 09/27/2005 01:30:00 7.8 0.5 8.8 6.5 7.5 0.5 9.1 6.5 50 3 46 305 6.8 0 7.4 6.9 09/27/2005 01:40:00 8.3 0.5 9.5 6.1 8.1 0.5 9.1 6.5 50 3 51 305 6.8 0 7.4 6.9 09/27/2005 01:50:00 7.8 0.5 8.8 6.5 7.6 0.5 8.8 5.7 46 3 48 305 6.8 0 7.4 6.9 09/27/2005 02:00:00 7.9 0.5 9.1 6.8 7.7 0.5 9.1 6.1 48 3 56 305 6.9 0 7.4 6.9 09/27/2005 02:10:00 7.8 0.5 9.1 6.5 7.7 0.5 9.5 6.1 46 3 46 305 6.9 0 7.4 6.9 09/27/2005 02:20:00 8.1 0.6 9.5 6.5 7.9 0.6 9.5 6.1 44 4 43 305 7 0 7.4 6.9 09/27/2005 02:30:00 7.9 0.6 9.5 6.1 7.7 0.7 9.1 5.7 51 5 46 305 7 0 7.4 6.9 09/27/2005 02:40:00 8 0.5 9.5 6.8 7.8 0.6 9.1 6.1 55 3 52 305 6.9 0 7.4 6.9 09/27/2005 02:50:00 7.5 0.6 8.4 5.7 7.3 0.6 8.4 5.3 55 4 61 305 6.8 0 6.9 6.9 09/27/2005 03:00:00 7.9 0.5 9.1 6.5 7.7 0.6 8.8 6.1 54 3 50 305 6.8 0 7.2 6.7 09/27/2005 03:10:00 8 0.5 9.1 6.5 7.7 0.5 9.1 6.8 54 3 57 305 6.8 0 6.9 6.9 09/27/2005 03:20:00 8.3 0.5 9.5 7.2 8.1 0.5 9.1 6.8 52 3 52 305 6.8 0 6.9 6.7 09/27/2005 03:30:00 8.2 0.5 9.5 6.8 8 0.5 9.5 6.8 53 4 52 305 6.8 0 6.9 6.9 09/27/2005 03:40:00 8.3 0.5 9.5 6.8 8.1 0.6 9.1 6.5 55 4 60 305 6.8 0 6.9 6.9 09/27/2005 03:50:00 8.7 0.5 9.9 7.2 8.4 0.6 9.9 6.8 56 3 56 305 6.7 0 6.9 6.7 09/27/2005 04:00:00 8.5 0.6 9.9 7.2 8.2 0.7 9.9 6.5 60 3 60 305 6.7 0 7.2 6.7 09/27/2005 04:10:00 7.8 0.6 9.1 6.5 7.7 0.6 9.1 6.1 60 3 60 305 6.7 0 7.2 6.7 09/27/2005 04:20:00 7.8 0.4 8.8 6.8 7.7 0.4 8.8 6.1 58 3 54 305 6.7 0 6.9 6.7 09/27/2005 04:30:00 7.6 0.5 8.8 6.5 7.5 0.5 8.4 6.5 55 3 58 305 6.7 0 6.9 6.7 09/27/2005 04:40:00 7.2 0.6 8.8 5.7 7.1 0.6 8.8 5.7 50 4 47 305 6.7 0 7.2 6.7 09/27/2005 04:50:00 8.3 0.6 9.9 6.5 8.1 0.6 9.5 6.1 50 4 44 305 6.8 0 7.2 6.7 09/27/2005 05:00:00 8.2 0.5 9.5 6.8 8.1 0.6 9.5 6.5 49 3 48 305 6.8 0 7.4 6.7 09/27/2005 05:10:00 8.1 0.6 9.5 6.5 8 0.6 9.1 5.7 53 4 58 305 6.8 0.1 7.4 6.7 09/27/2005 05:20:00 8.3 0.6 9.5 6.5 8.1 0.6 9.5 6.1 58 3 55 305 6.8 0 7.4 6.7 09/27/2005 05:30:00 7.9 0.6 9.1 6.1 7.7 0.6 9.1 6.1 56 3 56 305 6.9 0 7.4 6.9 09/27/2005 05:40:00 8.4 0.7 9.9 6.5 8.1 0.7 10.3 6.5 59 4 59 305 6.9 0 7.4 6.9 09/27/2005 05:50:00 9 0.6 10.3 7.6 8.7 0.6 10.3 7.2 57 4 59 305 6.9 0 7.4 6.9 09/27/2005 06:00:00 9.4 0.8 11.5 7.2 9.2 0.9 11.1 6.8 54 3 51 305 6.9 0 7.4 6.9 09/27/2005 06:10:00 9.1 0.6 10.7 7.6 8.9 0.6 11.1 7.6 51 4 56 305 6.9 0 7.4 6.9 09/27/2005 06:20:00 9.2 0.5 10.3 7.6 9.1 0.5 10.3 7.6 46 4 45 305 6.9 0 7.4 6.9 09/27/2005 06:30:00 9.1 0.6 11.1 7.2 9 0.7 10.7 7.2 44 3 43 305 6.8 0 7.4 6.7 09/27/2005 06:40:00 9 0.6 10.3 7.2 9 0.7 10.7 6.8 45 4 47 305 6.8 0 7.4 6.7 09/27/2005 06:50:00 8.9 0.6 10.3 6.8 8.8 0.6 9.9 6.8 39 4 44 305 6.9 0 7.4 6.9 09/27/2005 07:00:00 9.1 0.5 10.3 7.6 9 0.6 10.3 7.6 36 4 42 305 6.9 0 7.4 6.9 09/27/2005 07:10:00 8.5 0.6 10.3 7.2 8.4 0.6 10.3 7.2 33 3 36 305 6.8 0 7.4 6.9 09/27/2005 07:20:00 9.3 0.6 10.7 7.6 9.2 0.7 10.7 7.2 34 3 35 305 6.8 0 6.9 6.7 09/27/2005 07:30:00 9.6 0.6 11.1 8.4 9.6 0.6 10.7 8 37 3 32 305 6.8 0 6.9 6.7 09/27/2005 07:40:00 9.1 0.6 10.3 7.2 9.1 0.6 10.3 7.2 36 3 35 305 6.7 0 6.9 6.7 09/27/2005 07:50:00 9.2 0.7 10.7 7.2 9.1 0.7 10.7 6.8 36 3 36 305 6.6 0 6.9 6.4 09/27/2005 08:00:00 9.4 0.4 10.3 8.4 9.4 0.4 10.3 8 35 2 33 305 6.6 0 7.2 6.4 09/27/2005 08:10:00 9.1 0.5 10.7 7.6 9 0.5 10.3 7.6 33 3 36 305 6.6 0 6.9 6.4 09/27/2005 08:20:00 9.3 0.5 10.7 8 9.3 0.6 10.7 7.6 34 3 38 305 6.6 0 6.7 6.4 09/27/2005 08:30:00 9.4 0.6 11.1 7.6 9.4 0.6 11.1 7.6 39 3 38 305 6.6 0 6.7 6.4 09/27/2005 08:40:00 9 0.6 10.3 7.2 9 0.6 10.3 7.2 41 4 35 305 6.6 0 6.7 6.4 09/27/2005 08:50:00 9.1 0.5 10.3 7.6 9.2 0.5 10.3 7.6 41 3 39 305 6.7 0 6.9 6.4 09/27/2005 09:00:00 8.8 0.5 10.3 7.6 8.9 0.5 10.3 7.6 34 5 27 305 6.7 0 6.9 6.4 09/27/2005 09:10:00 9.4 0.6 10.7 8 9.4 0.6 11.1 8 27 4 29 305 6.7 0 6.9 6.7 09/27/2005 09:20:00 9.5 0.5 10.7 7.6 9.5 0.6 10.7 8 20 3 19 305 6.7 0 6.9 6.7 09/27/2005 09:30:00 9.2 0.5 10.3 8 9.3 0.5 10.3 8 17 3 15 305 6.7 0 7.2 6.4 09/27/2005 09:40:00 8.7 0.6 10.3 6.8 8.8 0.6 10.7 7.2 16 3 12 305 6.7 0.1 7.4 6.4 09/27/2005 09:50:00 9.1 0.6 10.3 7.6 9.2 0.6 11.1 7.6 16 4 18 305 6.8 0.1 7.4 6.7 09/27/2005 10:00:00 9.5 0.5 10.7 8 9.5 0.5 10.7 8 15 3 17 305 6.7 0.1 7.2 6.7 09/27/2005 10:10:00 9.4 0.5 10.7 8 9.4 0.6 10.7 8 16 3 18 305 6.7 0.1 7.2 6.7 09/27/2005 10:20:00 9.4 0.6 10.7 7.6 9.4 0.6 11.1 7.6 18 3 21 305 6.7 0.1 7.2 6.7 09/27/2005 10:30:00 9.3 0.7 11.1 7.6 9.3 0.7 11.1 7.6 21 3 21 305 6.8 0 7.4 6.7 09/27/2005 10:40:00 9.3 0.6 10.7 7.6 9.3 0.7 11.1 7.2 21 4 15 305 6.7 0.1 7.4 6.7 09/27/2005 10:50:00 9.4 0.6 10.7 7.6 9.5 0.7 11.1 7.2 18 3 18 305 6.7 0.2 7.2 6.7 09/27/2005 11:00:00 9.3 0.6 10.3 7.6 9.3 0.6 10.7 7.6 17 3 15 305 6.8 0.1 7.4 6.7 09/27/2005 11:10:00 9.3 0.5 10.3 7.6 9.4 0.5 10.7 8 16 2 21 305 6.8 0.1 7.4 6.7 09/27/2005 11:20:00 8.7 0.6 9.9 6.8 8.7 0.7 10.3 6.5 15 3 14 305 7 0 7.4 6.9 09/27/2005 11:30:00 8.9 0.7 10.3 6.8 9 0.7 10.7 6.8 11 3 12 305 7 0 7.4 6.9 09/27/2005 11:40:00 8.9 0.6 10.3 7.6 9 0.6 10.3 7.6 13 4 13 305 6.9 0 7.4 6.9 09/27/2005 11:50:00 9.9 0.6 11.5 8 9.9 0.7 11.5 8 15 3 17 305 6.9 0 7.2 6.9 09/27/2005 12:00:00 10.4 0.5 11.5 8.8 10.4 0.5 11.8 9.1 17 3 15 305 6.9 0 7.4 6.9 09/27/2005 12:10:00 10.4 0.6 11.8 8.4 10.2 0.7 12.2 8 22 4 18 305 6.9 0 7.4 6.9 09/27/2005 12:20:00 10.2 0.7 11.8 8.4 10.2 0.8 12.2 7.2 24 3 22 305 7 0 7.4 7.2 09/27/2005 12:30:00 10.2 0.6 11.5 8.4 10.1 0.7 11.8 7.6 23 3 22 305 7 0 7.2 6.9 09/27/2005 12:40:00 9.9 0.7 11.5 8 9.9 0.8 11.5 8 25 3 22 305 6.9 0 7.2 6.9 09/27/2005 12:50:00 10.2 0.7 11.5 8 10.1 0.7 11.8 7.6 23 3 20 305 6.9 0 7.2 6.9 09/27/2005 13:00:00 10.4 0.8 11.8 7.6 10.4 0.9 12.2 8 19 4 24 305 6.8 0 7.2 6.7 09/27/2005 13:10:00 10.5 0.7 12.2 8.8 10.6 0.8 12.6 8.4 22 3 22 305 6.7 0 6.9 6.7 09/27/2005 13:20:00 10.4 0.9 12.2 8 10.3 1 12.6 8 24 4 27 305 6.9 0 7.2 6.7 09/27/2005 13:30:00 10.5 0.7 12.2 8.4 10.5 0.8 12.2 8.4 23 3 21 305 6.9 0 7.2 6.9 09/27/2005 13:40:00 10.6 0.8 12.2 8.4 10.5 1 12.6 8 21 5 29 305 6.8 0 7.2 6.9 09/27/2005 13:50:00 10.6 0.5 11.8 8.8 10.6 0.6 11.8 8.8 20 4 23 305 6.8 0 7.2 6.9 09/27/2005 14:00:00 10.5 0.6 11.8 8.8 10.5 0.7 11.8 8.4 18 3 18 305 6.9 0 7.4 6.9 09/27/2005 14:10:00 10.1 0.7 11.5 8.4 10.2 0.8 11.8 8.4 17 3 19 305 7 0 7.4 6.9 09/27/2005 14:20:00 10.2 0.6 11.8 8.8 10.3 0.6 11.8 8.8 19 3 20 305 7.1 0 7.7 7.2 09/27/2005 14:30:00 10.6 1 12.6 7.2 10.7 1.1 12.2 7.2 19 3 24 305 7.1 0.1 7.7 7.2 09/27/2005 14:40:00 11.2 0.7 12.6 9.1 11.2 0.7 13 9.5 20 3 19 305 7 0 7.7 7.2 09/27/2005 14:50:00 11.6 0.7 13 8.8 11.5 0.8 13.3 9.5 21 3 19 305 7 0 7.4 6.9 09/27/2005 15:00:00 11.6 0.9 13.3 8.8 11.6 1 13.7 8.8 22 3 25 305 7 0 7.7 6.9 09/27/2005 15:10:00 11.6 0.8 13.7 9.5 11.6 1 14.1 9.1 25 3 21 305 7 0 7.4 6.9 09/27/2005 15:20:00 11.8 0.8 13.7 9.9 11.8 0.9 14.1 9.5 24 3 22 305 7 0 7.7 6.9 09/27/2005 15:30:00 11.8 0.8 13.3 9.5 11.9 0.9 13.7 9.5 22 3 22 305 6.9 0 7.7 6.9 09/27/2005 15:40:00 10.7 1 12.6 8 10.7 1 13 8 24 4 21 305 6.9 0 7.4 6.9 09/27/2005 15:50:00 10.8 0.7 12.2 8.8 10.8 0.8 12.6 8.8 24 4 27 305 7 0 7.4 6.9 09/27/2005 16:00:00 10.8 0.7 12.2 8.8 10.8 0.8 13 8.8 23 4 19 305 7 0 7.4 6.9 09/27/2005 16:10:00 11.6 0.8 13.3 8.8 11.5 0.9 13.3 8.8 25 4 24 305 6.9 0 7.4 6.9 09/27/2005 16:20:00 11.2 0.8 13.3 8 11.2 0.8 13.3 8.4 24 4 24 305 6.9 0 7.2 6.9 09/27/2005 16:30:00 11.2 0.6 13 9.5 11.2 0.7 13 9.5 23 4 16 305 6.9 0 7.2 6.9 09/27/2005 16:40:00 11.7 0.7 13.7 9.9 11.7 0.8 13.7 9.5 23 3 24 305 6.9 0 7.2 6.9 09/27/2005 16:50:00 12 0.7 13.7 9.5 12 0.8 13.7 9.9 23 4 24 305 7 0 7.2 6.9 09/27/2005 17:00:00 11.4 1 14.1 8.8 11.3 1.1 13.7 8.4 24 4 24 305 7 0 7.2 6.9 09/27/2005 17:10:00 11.1 0.8 13 9.1 11.1 0.9 13.3 8.8 24 4 23 305 7 0 7.2 6.9 09/27/2005 17:20:00 11 0.7 12.6 9.1 10.9 0.8 12.6 8.8 24 4 25 305 7 0 7.2 6.9 09/27/2005 17:30:00 11.2 1 13.3 8.8 11.1 1.1 13.7 8.4 25 4 26 305 7 0 7.2 6.9 09/27/2005 17:40:00 11.6 0.9 13.7 9.5 11.6 0.9 14.1 9.5 24 4 23 305 7 0 7.2 7.2 09/27/2005 17:50:00 11.7 0.9 14.1 9.5 11.6 1 14.5 9.1 27 4 29 305 7.1 0 7.2 7.2 09/27/2005 18:00:00 12.3 0.9 14.9 9.9 12.2 1 14.9 9.9 26 4 24 305 7.2 0 7.4 7.2 09/27/2005 18:10:00 12.9 0.9 15.3 10.3 12.7 1 15.3 9.5 26 3 27 305 7.2 0 7.4 7.2 09/27/2005 18:20:00 12.5 1 14.9 9.5 12.4 1.1 15.3 9.5 25 4 26 305 7.2 0 7.4 7.2 09/27/2005 18:30:00 12.7 1 14.9 9.9 12.6 1.1 15.3 9.5 25 4 28 305 7.2 0 7.7 7.2 09/27/2005 18:40:00 13.1 1 16.1 10.7 13 1 15.3 10.7 27 4 24 305 7.3 0.1 7.9 7.2 09/27/2005 18:50:00 13.1 0.7 14.9 11.5 13.1 0.8 15.3 11.1 25 4 29 305 7.3 0.1 7.9 7.2 09/27/2005 19:00:00 13.1 1 15.6 10.7 13 1.1 16.4 10.7 25 4 21 305 7.3 0.1 7.7 7.2 09/27/2005 19:10:00 13.2 1.3 16.4 9.9 13.1 1.3 16.4 9.9 26 5 26 305 7.3 0.1 7.7 7.2 09/27/2005 19:20:00 14 1.2 16.4 10.7 13.8 1.3 16.4 10.7 26 4 27 305 7.2 0.1 7.7 7.2 09/27/2005 19:30:00 13.5 1.2 16.8 10.7 13.4 1.3 16.4 10.7 25 4 19 305 7.2 0.1 7.7 7.2 09/27/2005 19:40:00 13.8 1.2 16.4 10.7 13.6 1.3 16.4 10.3 27 5 24 305 7.2 0.1 7.7 7.2 09/27/2005 19:50:00 14.8 1.1 17.6 11.5 14.6 1.1 17.2 11.8 29 4 27 305 7.2 0.1 7.7 7.2 09/27/2005 20:00:00 15.2 1.4 17.9 11.1 14.9 1.5 17.9 10.3 30 4 28 305 7.3 0.1 7.9 7.2 09/27/2005 20:10:00 14.7 1.3 18.7 11.8 14.5 1.3 18.3 11.1 30 5 26 305 7.3 0.1 7.7 7.2 09/27/2005 20:20:00 14.9 1.3 17.9 11.8 14.7 1.3 18.3 11.1 28 4 30 305 7.3 0 7.9 7.2 09/27/2005 20:30:00 14.9 1.2 17.9 12.2 14.7 1.2 17.9 11.1 29 4 25 305 7.3 0 7.9 7.2 09/27/2005 20:40:00 14.8 1.2 17.6 11.8 14.7 1.3 17.2 10.7 27 4 27 305 7.3 0 7.9 7.4 09/27/2005 20:50:00 13.8 1.1 16.4 11.1 13.7 1.2 16.8 10.3 27 5 31 305 7.3 0 7.9 7.2 09/27/2005 21:00:00 14.1 1.2 16.8 11.1 13.9 1.3 17.2 10.7 27 5 30 305 7.3 0 7.4 7.2 09/27/2005 21:10:00 13.7 1 16.4 11.5 13.7 1.1 16.4 11.1 24 4 29 305 7.1 0 7.4 7.2 09/27/2005 21:20:00 14.1 1.1 16.4 11.5 14.1 1.2 16.8 11.1 23 4 29 305 7 0 7.2 7.2 09/27/2005 21:30:00 14.4 1 16.8 12.2 14.3 1 16.4 11.8 23 4 24 305 7 0 7.2 6.9 09/27/2005 21:40:00 13.9 1.1 16.4 11.5 14 1.1 16.1 11.1 23 4 25 305 7 0 7.2 7.2 09/27/2005 21:50:00 14 1.1 16.4 10.7 14 1.2 16.8 10.7 21 4 20 305 7 0 7.2 7.2 09/27/2005 22:00:00 14 1 16.4 10.7 13.9 1 16.4 11.5 22 4 28 305 7 0 7.2 7.2 09/27/2005 22:10:00 14.4 1 17.2 11.8 14.3 1.1 17.9 11.1 19 4 23 305 7.1 0 7.2 7.2 09/27/2005 22:20:00 14.3 1.1 17.2 11.5 14.2 1.2 17.2 11.1 18 4 17 305 7.1 0 7.4 7.2 09/27/2005 22:30:00 13.8 1 16.4 11.1 13.7 1 16.1 11.1 18 4 15 305 7 0 7.2 7.2 09/27/2005 22:40:00 13.1 1.2 16.4 10.3 13.2 1.3 16.4 10.3 16 4 17 305 7 0 7.2 7.2 09/27/2005 22:50:00 14.1 1 16.4 11.5 14.1 1.1 16.4 10.7 16 4 17 305 7 0 7.2 7.2 09/27/2005 23:00:00 13 0.9 15.3 9.9 13.1 0.9 15.6 10.7 15 4 18 305 7 0 7.2 7.2 09/27/2005 23:10:00 13.3 1.1 16.1 9.9 13.3 1.1 15.6 9.9 17 4 13 305 7 0 7.2 6.9 09/27/2005 23:20:00 13.1 1 15.3 10.7 13.2 1 15.6 10.7 15 4 16 305 7 0 7.2 6.9 09/27/2005 23:30:00 12.2 0.9 14.9 10.3 12.3 1.1 14.9 9.5 11 3 14 305 7 0 7.2 6.9 09/27/2005 23:40:00 13.1 1 16.8 10.7 13.2 1.1 16.8 10.7 11 4 12 305 6.9 0 7.2 6.9 09/27/2005 23:50:00 13.4 1.2 16.4 10.3 13.6 1.2 16.8 10.3 12 4 10 305 6.8 0 6.9 6.9 09/28/2005 00:00:00 13.3 1 15.6 10.7 13.5 1 15.6 11.1 11 4 10 305 6.7 0 7.2 6.7 09/28/2005 00:10:00 13.4 1 16.1 10.7 13.4 1.1 16.4 10.3 9 4 18 305 6.6 0 7.2 6.4 09/28/2005 00:20:00 13.5 1.1 15.6 10.7 13.6 1.1 16.1 10.7 6 4 10 305 6.5 0 6.7 6.4 09/28/2005 00:30:00 13.2 0.9 15.6 10.7 13.3 0.9 16.1 10.3 6 4 4 305 6.4 0 6.9 6.1 09/28/2005 00:40:00 12.9 1 15.6 9.9 13.1 1.2 16.1 9.5 7 4 7 305 6.3 0 6.4 6.1 09/28/2005 00:50:00 13.2 1.2 16.4 10.3 13.1 1.2 16.4 10.3 7 4 7 305 6.2 0 6.4 6.1 09/28/2005 01:00:00 13.7 1.2 17.6 10.7 13.8 1.3 17.6 10.7 6 5 12 305 6.2 0 6.4 6.1 09/28/2005 01:10:00 14.2 1 16.4 11.8 14.3 1 16.4 11.1 5 4 1 305 6.2 0 6.4 6.1 09/28/2005 01:20:00 14.8 1.2 17.2 11.1 14.8 1.3 17.2 11.5 6 4 6 305 6.2 0 6.4 6.1 09/28/2005 01:30:00 14 1.7 17.2 10.3 14.2 1.7 17.2 10.7 4 4 3 305 6.1 0 6.4 5.9 09/28/2005 01:40:00 12.8 1.3 15.6 9.5 12.8 1.4 15.6 9.1 3 5 359 305 6 0 6.1 5.9 09/28/2005 01:50:00 13.3 1.1 15.6 9.9 13.3 1.1 15.6 10.3 1 4 1 305 5.9 0 6.1 5.6 09/28/2005 02:00:00 14.5 1.1 16.8 11.1 14.6 1.3 17.6 10.7 2 4 1 305 5.8 0 5.9 5.6 09/28/2005 02:10:00 13.6 1.5 16.4 9.9 13.6 1.5 16.4 9.1 3 5 3 305 5.8 0 5.9 5.6 09/28/2005 02:20:00 14.1 1.1 16.4 11.5 14.2 1.1 16.4 11.5 4 4 2 305 5.8 0 5.9 5.6 09/28/2005 02:30:00 13.8 1.1 16.4 10.3 14 1.2 16.8 10.3 4 4 5 305 5.9 0 5.9 5.6 09/28/2005 02:40:00 14.3 1 16.4 11.8 14.4 1.1 16.8 11.5 5 4 4 305 5.8 0 5.9 5.6 09/28/2005 02:50:00 13.4 1 15.6 10.3 13.5 1.1 15.6 9.5 359 4 1 305 5.8 0 5.9 5.6 09/28/2005 03:00:00 13.7 1.1 16.1 11.1 13.7 1.1 16.4 11.1 358 4 357 305 5.6 0 5.9 5.6 09/28/2005 03:10:00 13.8 1.1 16.8 10.7 14 1.2 16.8 10.7 359 3 358 305 5.6 0 5.6 5.4 09/28/2005 03:20:00 13.3 1.2 15.6 10.3 13.5 1.3 16.1 9.5 359 4 2 305 5.6 0 5.9 5.4 09/28/2005 03:30:00 12.9 1 15.3 10.3 13 1.2 16.1 9.1 357 4 0 305 5.6 0 5.9 5.6 09/28/2005 03:40:00 12.8 0.9 14.9 9.9 13 1.1 15.6 9.5 354 4 2 305 5.6 0 5.9 5.6 09/28/2005 03:50:00 13 1.2 15.3 9.1 13.1 1.3 15.3 8 356 4 356 305 5.6 0 5.9 5.4 09/28/2005 04:00:00 12.7 1 14.9 9.5 13 1.2 15.3 9.1 355 4 2 305 5.5 0 5.6 5.4 09/28/2005 04:10:00 12 1 14.5 9.1 12.2 1.1 14.5 9.5 359 4 0 305 5.5 0 5.9 5.4 09/28/2005 04:20:00 12.4 1.1 14.5 9.9 12.6 1.2 14.9 8.8 359 4 359 305 5.6 0 5.9 5.4 09/28/2005 04:30:00 12.5 1 14.5 9.9 12.7 1.1 14.9 9.1 0 4 357 305 5.6 0 5.9 5.4 09/28/2005 04:40:00 12.1 1 14.1 9.5 12.3 1.1 14.5 9.1 356 4 353 305 5.6 0 5.6 5.4 09/28/2005 04:50:00 12 1 14.1 9.1 12.1 1 14.1 8.8 356 5 356 305 5.6 0 5.9 5.4 09/28/2005 05:00:00 12.7 0.9 14.5 9.5 12.8 1 14.9 9.1 354 4 350 305 5.5 0 6.1 5.4 09/28/2005 05:10:00 12.3 0.8 14.1 9.5 12.5 1 14.5 9.5 354 4 357 305 5.5 0 5.6 5.4 09/28/2005 05:20:00 12.3 0.9 14.1 9.9 12.4 1 14.5 10.3 355 4 351 305 5.5 0 5.6 5.4 09/28/2005 05:30:00 12.1 1 14.1 9.5 12.3 1 14.5 9.1 355 4 351 305 5.5 0 5.6 5.4 09/28/2005 05:40:00 12.2 0.9 14.1 9.5 12.4 1 14.5 8.8 355 4 0 305 5.5 0 5.6 5.4 09/28/2005 05:50:00 12.4 1.1 14.5 9.1 12.5 1.2 14.9 8.8 356 4 352 305 5.5 0 5.6 5.4 09/28/2005 06:00:00 12.1 0.9 13.7 9.5 12.2 1 14.5 9.5 357 4 351 305 5.5 0 6.1 5.4 09/28/2005 06:10:00 11.3 0.9 14.1 8.8 11.5 1 14.1 9.1 358 4 356 305 5.6 0 5.9 5.6 09/28/2005 06:20:00 11.8 0.8 13.3 9.5 11.9 1 13.7 9.5 358 4 359 305 5.6 0 5.9 5.6 09/28/2005 06:30:00 11.9 0.8 14.1 9.5 12.2 0.9 14.1 9.1 358 5 1 305 5.7 0 5.9 5.6 09/28/2005 06:40:00 12.1 1 14.5 9.5 12.3 1 14.5 9.1 359 4 359 305 5.7 0 5.9 5.6 09/28/2005 06:50:00 12.1 0.9 13.7 9.9 12.3 1 14.5 9.5 2 4 7 305 5.7 0 5.9 5.6 09/28/2005 07:00:00 11.8 1 13.7 9.1 12 1.1 14.1 8.4 359 4 357 305 5.6 0 5.9 5.6 09/28/2005 07:10:00 12 0.8 13.7 9.1 12.3 0.9 14.1 9.5 1 4 4 305 5.6 0 5.9 5.4 09/28/2005 07:20:00 11.6 0.9 13.7 9.1 11.7 1.1 14.1 8.8 1 4 358 305 5.6 0 5.9 5.6 09/28/2005 07:30:00 11.6 1.2 14.1 8.8 11.8 1.3 14.1 8 4 4 5 305 5.6 0 5.9 5.6 09/28/2005 07:40:00 12 0.9 14.1 9.5 12.2 0.9 14.1 9.9 1 4 0 305 5.6 0 5.9 5.6 09/28/2005 07:50:00 12.2 0.8 14.1 9.1 12.4 0.9 14.5 9.5 1 4 358 305 5.6 0 5.9 5.4 09/28/2005 08:00:00 12.3 0.9 14.5 9.5 12.5 1 14.5 9.5 359 3 0 305 5.6 0 5.9 5.4 09/28/2005 08:10:00 12.1 1 14.1 9.1 12.2 1.1 14.5 9.1 1 5 2 305 5.6 0 5.6 5.4 09/28/2005 08:20:00 11.5 1 14.1 9.1 11.7 1.1 14.5 8.8 2 5 1 305 5.5 0 5.6 5.4 09/28/2005 08:30:00 12.3 1 14.1 9.5 12.5 1 14.5 9.5 1 5 359 305 5.4 0 5.6 5.4 09/28/2005 08:40:00 11.9 1 14.5 9.9 12 1.1 14.9 8.8 5 5 357 305 5.4 0 5.6 5.4 09/28/2005 08:50:00 11.8 0.8 13.7 9.5 12 0.9 14.1 9.5 5 5 8 305 5.5 0 5.6 5.4 09/28/2005 09:00:00 12.2 1 14.9 9.5 12.3 1.1 14.5 9.1 7 4 8 305 5.5 0 5.6 5.4 09/28/2005 09:10:00 12.6 1.2 15.6 9.5 12.8 1.2 15.6 9.9 10 5 9 305 5.5 0 5.6 5.4 09/28/2005 09:20:00 13.5 0.8 15.6 9.9 13.7 1 16.1 10.3 8 3 7 305 5.4 0 5.6 5.4 09/28/2005 09:30:00 12.6 1 15.3 9.9 12.7 1.1 15.3 9.5 9 4 14 305 5.5 0 5.6 5.4 09/28/2005 09:40:00 12.8 1 15.3 10.3 12.9 1.1 15.3 9.5 8 5 12 305 5.3 0 5.6 5.2 09/28/2005 09:50:00 13.7 0.9 15.6 11.1 13.8 1 15.6 10.3 10 4 9 305 5.2 0 5.4 4.9 09/28/2005 10:00:00 13.6 1.1 15.6 10.7 13.7 1.1 16.1 9.9 9 4 8 305 5.2 0 5.4 5.2 09/28/2005 10:10:00 13.3 0.9 15.3 10.3 13.3 1 15.3 10.7 9 4 2 305 5.3 0 5.4 5.2 09/28/2005 10:20:00 13.3 1 15.3 10.3 13.3 1.2 15.6 9.5 9 4 8 305 5.3 0 5.4 5.2 09/28/2005 10:30:00 13.2 1 15.3 11.1 13.3 1 15.6 10.7 8 5 15 305 5.3 0 5.4 5.2 09/28/2005 10:40:00 13 1.1 15.3 9.1 13.1 1.2 15.3 8.8 11 4 9 305 5.4 0 5.6 5.2 09/28/2005 10:50:00 12.7 0.9 14.9 9.9 12.8 1 15.3 10.3 6 5 4 305 5.4 0 5.6 5.4 09/28/2005 11:00:00 12.5 1.1 15.3 9.1 12.8 1.2 15.3 9.1 6 4 10 305 5.4 0 5.6 5.4 09/28/2005 11:10:00 13.1 1.2 15.3 9.5 13.4 1.2 15.6 9.5 6 4 7 305 5.4 0 5.6 5.4 09/28/2005 11:20:00 13.7 1 16.1 11.1 13.7 1.1 16.1 10.3 5 4 10 305 5.4 0 5.6 5.4 09/28/2005 11:30:00 13 1 15.3 9.9 13.2 1 15.6 10.3 5 3 4 305 5.3 0 5.4 5.2 09/28/2005 11:40:00 12.5 1.1 14.9 9.9 12.6 1.2 14.9 8.8 7 5 8 305 5.3 0 5.4 5.2 09/28/2005 11:50:00 13.5 1.2 16.1 9.9 13.6 1.3 16.1 9.5 6 4 9 305 5.3 0 5.4 5.2 09/28/2005 12:00:00 12.9 1 15.3 9.9 13.1 1 15.3 9.5 7 5 12 305 5.3 0 5.6 5.2 09/28/2005 12:10:00 13.1 1 14.9 9.5 13.3 1 15.3 10.3 3 4 7 305 5.3 0 5.4 5.2 09/28/2005 12:20:00 13.1 0.9 15.3 10.3 13.2 1 15.6 10.7 5 4 8 305 5.3 0 5.4 5.2 09/28/2005 12:30:00 13 0.8 14.9 10.3 13.2 0.8 15.3 10.3 8 4 3 305 5.4 0 5.6 5.4 09/28/2005 12:40:00 13.1 0.7 14.5 10.3 13.4 0.9 15.3 11.1 5 4 0 305 5.3 0 5.4 5.2 09/28/2005 12:50:00 12.7 0.9 14.5 10.3 13 0.9 14.9 10.3 7 5 4 305 5.4 0 5.4 5.4 09/28/2005 13:00:00 13.1 1.1 14.9 9.1 13.4 1.1 15.3 9.5 7 4 4 305 5.4 0 5.9 5.2 09/28/2005 13:10:00 13 1 15.3 10.3 13.1 1.2 15.6 9.1 6 5 6 305 5.3 0 5.4 5.2 09/28/2005 13:20:00 13.1 1 15.3 10.7 13.3 1 15.6 10.7 7 5 7 305 5.2 0 5.4 4.9 09/28/2005 13:30:00 13 0.9 14.9 10.7 13.2 1 15.3 10.3 10 4 14 305 5.2 0 5.4 4.9 09/28/2005 13:40:00 12.6 1.1 15.3 9.9 12.7 1.2 15.3 9.9 10 4 7 305 5.3 0 5.6 5.2 09/28/2005 13:50:00 12.8 0.9 14.5 9.9 12.9 1 15.3 9.9 12 4 7 305 5.3 0 5.6 5.2 09/28/2005 14:00:00 13.4 1 15.3 11.1 13.5 1 16.1 10.3 12 4 8 305 5.3 0 5.4 5.2 09/28/2005 14:10:00 13.9 0.8 15.6 11.5 13.9 0.9 16.1 10.7 10 3 9 305 5.3 0 5.4 5.2 09/28/2005 14:20:00 13.5 0.8 15.3 11.1 13.7 0.9 15.6 11.1 8 3 15 305 5.3 0 5.4 5.2 09/28/2005 14:30:00 13.2 0.9 15.3 10.3 13.3 1 15.3 9.9 7 4 5 305 5.3 0 5.4 5.2 09/28/2005 14:40:00 13.1 0.8 15.3 10.7 13.3 0.8 15.3 10.7 10 4 14 305 5.4 0 5.6 5.2 09/28/2005 14:50:00 13 1 14.9 10.3 13.2 1 15.3 9.9 8 4 6 305 5.4 0 5.6 5.4 09/28/2005 15:00:00 12.8 1 14.9 10.3 13 1 15.3 10.7 7 4 4 305 5.4 0 5.6 5.4 09/28/2005 15:10:00 13.2 0.8 14.9 11.1 13.3 1 15.3 10.7 8 4 4 305 5.4 0 5.6 5.4 09/28/2005 15:20:00 13.6 0.9 15.3 11.1 13.7 1 15.6 11.1 7 4 9 305 5.4 0 5.6 5.4 09/28/2005 15:30:00 13.1 1 14.9 9.1 13.2 1.1 15.3 9.1 5 4 2 305 5.5 0 5.6 5.4 09/28/2005 15:40:00 12.7 1 14.9 9.5 12.9 1 15.6 9.1 5 4 358 305 5.6 0 5.9 5.4 09/28/2005 15:50:00 13.2 0.8 14.9 10.7 13.3 1 15.3 9.1 3 4 8 305 5.6 0 5.9 5.6 09/28/2005 16:00:00 12.4 1.3 15.3 8.4 12.4 1.5 15.3 8.4 7 5 9 305 5.8 0 5.9 5.6 09/28/2005 16:10:00 12.1 1 14.5 8.8 12.3 1 14.5 8.4 5 6 5 305 5.8 0 5.9 5.6 09/28/2005 16:20:00 12 1 14.1 9.9 12.1 1 14.5 9.5 4 5 3 305 5.6 0 5.9 5.4 09/28/2005 16:30:00 11.8 0.8 13.7 9.1 12 0.9 14.5 9.9 2 5 2 305 5.6 0 5.6 5.4 09/28/2005 16:40:00 12.4 0.7 14.5 10.3 12.5 0.9 14.5 9.9 5 4 9 305 5.6 0 5.9 5.4 09/28/2005 16:50:00 11.8 0.9 13.7 8.8 12 1 14.1 8.8 5 4 358 305 5.7 0 5.9 5.6 09/28/2005 17:00:00 11.9 1 13.7 9.5 12 1.1 14.1 9.1 6 4 8 305 5.8 0 5.9 5.6 09/28/2005 17:10:00 11.7 1 13.7 9.5 11.8 1.1 14.1 9.1 8 4 4 305 5.8 0 5.9 5.6 09/28/2005 17:20:00 12.3 0.7 13.7 10.3 12.4 0.8 14.1 9.9 10 3 5 305 5.9 0 5.9 5.9 09/28/2005 17:30:00 12 0.7 13.7 9.5 12.1 0.8 14.1 9.5 11 3 7 305 6 0 6.1 5.9 09/28/2005 17:40:00 11.4 0.8 13.3 9.1 11.6 0.9 14.1 8.8 14 5 5 305 5.9 0 6.1 5.9 09/28/2005 17:50:00 11.5 0.9 13.7 8.8 11.7 1 14.1 8.8 15 5 14 305 5.9 0 6.1 5.9 09/28/2005 18:00:00 12 0.8 13.7 9.9 12.1 1 14.1 9.5 14 4 14 305 5.9 0 6.1 5.6 09/28/2005 18:10:00 11.6 1.2 14.1 8.8 11.7 1.3 14.5 8.4 15 4 15 305 5.8 0 5.9 5.6 09/28/2005 18:20:00 12.3 0.7 13.7 9.5 12.3 0.8 14.5 9.5 17 4 12 305 5.6 0 5.9 5.6 09/28/2005 18:30:00 12 0.9 14.1 9.5 12.1 1 14.1 9.1 17 4 19 305 5.6 0 5.9 5.6 09/28/2005 18:40:00 11.7 1 13.7 8.8 11.8 1.1 14.1 8.8 17 5 26 305 5.6 0 5.9 5.4 09/28/2005 18:50:00 11.7 0.9 13.3 9.1 11.9 0.9 13.7 9.5 18 5 12 305 5.6 0 5.6 5.4 09/28/2005 19:00:00 11.5 0.8 13.3 9.1 11.7 0.9 13.3 8.8 16 4 16 305 5.5 0 5.6 5.4 09/28/2005 19:10:00 11.8 0.7 13.3 9.9 11.9 0.9 13.3 9.5 14 3 13 305 5.5 0 5.6 5.4 09/28/2005 19:20:00 10.9 1 13 8 10.9 1.1 13.3 8 17 4 12 305 5.5 0 5.6 5.4 09/28/2005 19:30:00 11 0.8 13.3 9.1 11.1 1 13.7 8.4 16 5 21 305 5.4 0 5.6 5.4 09/28/2005 19:40:00 11.1 0.7 12.6 8.8 11.2 0.8 13 8.4 16 4 14 305 5.4 0 5.6 5.4 09/28/2005 19:50:00 10.8 0.9 12.6 8.8 10.8 1 12.6 8 16 5 17 305 5.5 0 5.6 5.4 09/28/2005 20:00:00 11 0.6 12.2 9.1 11.1 0.7 12.6 8.8 18 3 21 305 5.5 0 5.6 5.4 09/28/2005 20:10:00 10.9 0.8 12.2 8.4 11.1 0.8 13 8.4 18 3 19 305 5.5 0 5.6 5.4 09/28/2005 20:20:00 10.2 0.9 12.2 8 10.2 0.9 12.2 8.4 16 4 17 305 5.4 0 5.6 5.4 09/28/2005 20:30:00 10 1 12.2 8 10.1 1 12.2 7.6 16 4 15 305 5.4 0 5.6 5.4 09/28/2005 20:40:00 10.5 0.8 12.2 8.4 10.6 0.8 12.6 8 17 4 13 305 5.4 0 5.6 5.4 09/28/2005 20:50:00 10.4 0.7 11.5 8.4 10.4 0.8 12.2 7.6 16 4 18 305 5.4 0 5.6 5.4 09/28/2005 21:00:00 9.8 0.6 11.1 8 9.9 0.7 11.5 8 20 4 21 305 5.4 0 5.6 5.4 09/28/2005 21:10:00 10.3 0.8 11.8 8 10.4 0.9 12.2 8 18 5 23 305 5.3 0 5.4 5.2 09/28/2005 21:20:00 10.1 0.6 11.5 8 10.2 0.7 12.2 8 15 3 13 305 5.3 0 5.4 5.2 09/28/2005 21:30:00 10.5 0.8 11.8 8 10.6 0.9 12.2 8 19 3 19 305 5.2 0 5.4 5.2 09/28/2005 21:40:00 10.3 0.6 11.8 8 10.4 0.7 11.8 8.4 22 4 25 305 5.2 0 5.4 5.2 09/28/2005 21:50:00 10.1 0.6 11.5 8.4 10.2 0.7 11.8 8 26 3 25 305 5.2 0 5.4 4.9 09/28/2005 22:00:00 10.1 0.6 11.5 8 10.2 0.6 11.5 8 24 4 19 305 5.1 0 5.4 4.9 09/28/2005 22:10:00 9.9 0.7 11.5 7.6 10 0.8 11.5 7.2 23 4 20 305 5 0 5.4 4.9 09/28/2005 22:20:00 10.2 0.6 11.5 8.4 10.3 0.7 11.5 8 22 4 21 305 5 0 5.2 4.9 09/28/2005 22:30:00 10.1 0.6 11.5 8.4 10.1 0.8 11.8 7.6 21 4 22 305 4.9 0 5.2 4.9 09/28/2005 22:40:00 9.7 0.7 11.1 7.6 9.9 0.8 11.5 7.6 21 4 16 305 4.8 0 5.2 4.9 09/28/2005 22:50:00 9.3 0.8 10.7 7.2 9.4 0.9 11.1 6.8 28 5 27 305 4.9 0 5.2 4.9 09/28/2005 23:00:00 10 0.6 11.5 8 10.1 0.7 11.8 8 26 4 28 305 4.8 0 5.2 4.9 09/28/2005 23:10:00 10 0.7 11.5 8.8 10.1 0.8 11.8 8 25 4 27 305 4.8 0 4.9 4.7 09/28/2005 23:20:00 10.5 0.6 11.8 8.8 10.6 0.7 12.2 8.4 24 5 26 305 4.8 0 4.9 4.9 09/28/2005 23:30:00 10.1 0.8 11.8 8 10.1 0.9 11.8 8 25 5 25 305 4.8 0 4.9 4.9 09/28/2005 23:40:00 10.6 0.6 11.8 8.4 10.7 0.7 12.2 8.8 24 3 27 305 4.8 0 5.2 4.7 09/28/2005 23:50:00 10.5 0.5 11.8 8.8 10.6 0.6 12.2 8.8 23 5 25 305 4.8 0 4.9 4.7 09/29/2005 00:00:00 9.9 0.7 11.5 7.6 10 0.8 11.8 8 20 5 16 305 4.8 0 5.4 4.9 09/29/2005 00:10:00 9.9 0.7 11.5 8 10 0.8 11.8 7.6 19 5 18 305 4.8 0 5.2 4.9 09/29/2005 00:20:00 10.4 0.6 11.8 8.8 10.5 0.6 11.8 8.8 19 5 17 305 4.8 0 4.9 4.9 09/29/2005 00:30:00 9.8 0.8 11.8 7.2 10 1 12.6 7.6 21 5 13 305 4.8 0 4.9 4.9 09/29/2005 00:40:00 10.2 0.5 11.5 8.4 10.3 0.6 11.8 8.4 22 5 24 305 4.8 0 4.9 4.7 09/29/2005 00:50:00 10 0.7 11.5 8 10.1 0.8 11.8 8 26 4 23 305 4.8 0 4.9 4.9 09/29/2005 01:00:00 10.6 0.7 12.2 8.4 10.7 0.7 12.2 7.6 21 5 21 305 4.8 0 4.9 4.7 09/29/2005 01:10:00 10.2 0.7 12.2 8.4 10.4 0.7 12.2 8.4 19 6 17 305 4.8 0 4.9 4.9 09/29/2005 01:20:00 9.6 0.8 11.5 7.6 9.7 0.9 11.8 7.6 21 4 11 305 4.8 0 4.9 4.9 09/29/2005 01:30:00 9.5 0.7 11.1 7.6 9.7 0.7 11.5 8 18 4 18 305 4.8 0 4.9 4.7 09/29/2005 01:40:00 9.7 0.5 11.1 8.4 9.9 0.6 11.5 8 19 4 15 305 4.8 0 4.9 4.7 09/29/2005 01:50:00 9.6 0.6 11.1 7.6 9.8 0.7 11.1 7.6 20 4 19 305 4.8 0 4.9 4.7 09/29/2005 02:00:00 9 0.6 10.3 7.6 9.1 0.7 10.7 7.2 20 5 15 305 4.8 0 4.9 4.7 09/29/2005 02:10:00 9 0.6 10.3 7.2 9.2 0.6 10.7 6.8 18 5 17 305 4.8 0 4.9 4.7 09/29/2005 02:20:00 8.9 0.6 10.3 7.2 9.1 0.6 10.3 7.6 17 5 20 305 4.8 0 4.9 4.7 09/29/2005 02:30:00 9 0.6 10.3 7.6 9.2 0.7 10.7 7.6 18 4 16 305 4.8 0 4.9 4.7 09/29/2005 02:40:00 9 0.6 10.3 7.2 9.2 0.6 10.7 7.2 20 4 24 305 4.8 0 4.9 4.7 09/29/2005 02:50:00 8.7 0.5 10.3 7.2 9 0.6 11.1 7.6 15 4 17 305 4.8 0 4.9 4.7 09/29/2005 03:00:00 9.1 0.6 10.7 6.5 9.3 0.7 11.1 6.8 18 5 21 305 4.8 0 4.9 4.7 09/29/2005 03:10:00 8.9 0.5 10.3 7.6 9.1 0.5 10.7 7.6 20 5 23 305 4.7 0 4.9 4.7 09/29/2005 03:20:00 9.1 0.5 10.3 7.6 9.2 0.6 10.7 7.6 21 3 24 305 4.7 0 4.9 4.7 09/29/2005 03:30:00 8.6 0.5 9.5 7.2 8.9 0.6 9.9 7.2 20 4 21 305 4.7 0 4.9 4.4 09/29/2005 03:40:00 8.7 0.6 9.9 7.2 9 0.6 10.3 7.2 17 4 18 305 4.6 0 4.9 4.4 09/29/2005 03:50:00 9 0.6 10.7 7.6 9.2 0.6 10.7 7.6 18 4 20 305 4.6 0 4.9 4.4 09/29/2005 04:00:00 9.4 0.5 10.3 8 9.6 0.5 11.1 8 18 3 14 305 4.6 0 4.9 4.4 09/29/2005 04:10:00 9 0.5 9.9 7.6 9.3 0.5 10.3 8 15 3 17 305 4.7 0 4.9 4.7 09/29/2005 04:20:00 9.3 0.6 11.1 7.2 9.4 0.7 11.5 7.6 15 4 11 305 4.8 0 4.9 4.7 09/29/2005 04:30:00 10 0.5 11.1 8.4 10.3 0.5 11.5 8.8 9 3 12 305 4.8 0 4.9 4.7 09/29/2005 04:40:00 9.9 0.5 11.5 8.4 10.1 0.6 11.8 8.4 8 3 7 305 4.8 0 4.9 4.7 09/29/2005 04:50:00 9.3 0.5 11.1 7.6 9.6 0.6 11.1 8 10 5 2 305 4.6 0 4.7 4.4 09/29/2005 05:00:00 9.4 0.6 10.3 7.6 9.7 0.7 11.1 7.6 10 4 12 305 4.5 0 4.7 4.4 09/29/2005 05:10:00 8.9 0.6 10.3 6.8 9.1 0.7 10.7 7.2 11 4 11 305 4.4 0 4.7 4.4 09/29/2005 05:20:00 9.1 0.6 10.3 7.2 9.4 0.7 11.1 7.2 12 5 6 305 4.4 0 4.7 4.4 09/29/2005 05:30:00 9 0.6 10.7 7.2 9.3 0.6 11.1 7.6 9 4 6 305 4.4 0 4.7 4.4 09/29/2005 05:40:00 8.9 0.8 10.3 6.8 9.2 0.8 10.7 7.2 12 4 10 305 4.4 0 4.7 4.4 09/29/2005 05:50:00 9.2 0.7 10.7 7.2 9.4 0.7 11.1 7.2 10 4 12 305 4.5 0 4.7 4.4 09/29/2005 06:00:00 9.4 0.6 11.1 7.6 9.6 0.7 11.1 7.6 11 5 13 305 4.5 0 4.7 4.4 09/29/2005 06:10:00 9.7 0.7 11.1 7.2 10 0.7 11.5 7.6 9 4 11 305 4.5 0 4.7 4.4 09/29/2005 06:20:00 9.7 0.6 11.1 8 10 0.6 11.8 8.4 11 5 11 305 4.6 0 4.9 4.4 09/29/2005 06:30:00 10.2 0.6 11.5 8.4 10.4 0.6 12.2 8.8 8 6 7 305 4.5 0 4.7 4.4 09/29/2005 06:40:00 10.1 0.6 11.5 8.4 10.3 0.7 11.8 8 5 4 2 305 4.4 0 4.7 4.4 09/29/2005 06:50:00 10.3 0.6 11.8 8.4 10.6 0.7 11.8 8.8 6 4 2 305 4.4 0 4.7 4.4 09/29/2005 07:00:00 10.5 0.6 11.8 8 10.8 0.6 12.2 8.8 4 3 8 305 4.4 0 4.7 4.4 09/29/2005 07:10:00 10.3 0.7 11.5 7.6 10.6 0.8 12.2 8 3 3 6 305 4.4 0 4.7 4.2 09/29/2005 07:20:00 10.1 0.7 11.5 8 10.4 0.8 12.2 7.6 2 4 2 305 4.4 0 4.4 4.2 09/29/2005 07:30:00 10.2 0.6 11.8 8 10.5 0.7 11.8 8.8 2 3 4 305 4.4 0 4.7 4.2 09/29/2005 07:40:00 10.4 0.6 11.5 8 10.7 0.6 12.2 8.4 4 4 4 305 4.4 0 4.7 4.4 09/29/2005 07:50:00 10.5 0.6 11.8 8.8 10.7 0.7 12.2 8.4 4 4 7 305 4.5 0 4.7 4.4 09/29/2005 08:00:00 10.3 0.6 11.8 8.4 10.6 0.7 12.2 8.8 4 4 5 305 4.6 0 4.9 4.4 09/29/2005 08:10:00 10.3 0.5 11.5 8.8 10.6 0.6 11.8 8.8 9 3 1 305 4.7 0 4.9 4.4 09/29/2005 08:20:00 10.2 0.8 11.8 8 10.5 0.9 12.2 7.2 10 4 11 305 4.7 0 4.9 4.7 09/29/2005 08:30:00 10.3 0.8 12.6 8 10.6 0.8 12.6 8.8 9 4 8 305 4.7 0 4.9 4.4 09/29/2005 08:40:00 10.5 0.6 11.8 7.2 10.8 0.7 11.8 7.6 8 3 11 305 4.7 0 4.9 4.7 09/29/2005 08:50:00 9.9 0.6 11.5 7.6 10.1 0.7 11.8 8.4 8 3 5 305 4.8 0 4.9 4.7 09/29/2005 09:00:00 9.5 0.6 10.7 8 9.8 0.7 11.1 8 10 3 8 305 5 0 5.2 4.9 09/29/2005 09:10:00 9.4 0.6 10.7 7.6 9.6 0.7 11.1 7.6 12 4 9 305 5.1 0 5.4 4.9 09/29/2005 09:20:00 8.8 0.5 10.7 7.2 9.1 0.6 10.7 7.6 13 3 20 305 5.2 0 5.4 5.2 09/29/2005 09:30:00 8.7 0.4 9.5 7.6 8.9 0.5 9.9 7.2 14 3 18 305 5.3 0 5.4 5.2 09/29/2005 09:40:00 8.9 0.5 10.3 7.2 9.1 0.5 10.3 7.6 8 3 10 305 5.3 0 5.4 5.2 09/29/2005 09:50:00 9 0.5 10.7 7.6 9.2 0.6 11.1 7.6 6 3 5 305 5.3 0 5.4 5.2 09/29/2005 10:00:00 8.8 0.6 10.3 7.2 9.1 0.7 10.7 6.8 8 4 4 305 5.5 0 5.6 5.4 09/29/2005 10:10:00 8.2 0.5 9.5 6.8 8.4 0.5 9.5 6.5 23 8 33 305 5.9 0 6.1 5.6 09/29/2005 10:20:00 8.3 0.5 9.1 6.8 8.3 0.5 9.5 6.5 30 3 27 305 6.1 0 6.1 5.9 09/29/2005 10:30:00 8.6 0.6 9.9 7.2 8.7 0.6 9.9 7.2 39 4 38 305 6.2 0 6.4 6.1 09/29/2005 10:40:00 9.1 0.6 10.3 7.2 9.2 0.7 10.7 7.2 40 3 38 305 6.2 0 6.4 6.1 09/29/2005 10:50:00 9.4 0.7 11.1 7.6 9.4 0.8 11.1 7.2 43 4 48 305 6.3 0 6.4 6.1 09/29/2005 11:00:00 9.3 0.7 10.7 7.6 9.4 0.7 11.1 6.5 41 3 44 305 6.3 0 6.4 6.1 09/29/2005 11:10:00 9.4 0.5 10.7 8 9.5 0.5 10.7 8 41 3 41 305 6.4 0 6.4 6.1 09/29/2005 11:20:00 9.6 0.5 11.1 8 9.6 0.6 10.7 7.6 39 4 35 305 6.5 0 6.7 6.4 09/29/2005 11:30:00 10.5 0.7 12.2 8 10.5 0.7 12.2 8 41 4 39 305 6.5 0 6.7 6.4 09/29/2005 11:40:00 11 0.8 12.6 8.8 11 0.8 13 8.8 38 8 46 305 6.5 0 6.9 6.1 09/29/2005 11:50:00 11.4 0.6 13 9.1 11.4 0.7 13 8.8 30 4 28 305 6.1 0 6.4 5.9 09/29/2005 12:00:00 10.9 0.9 12.6 8 10.7 0.9 12.6 8.4 28 4 31 305 6.2 0 6.7 6.1 09/29/2005 12:10:00 11.3 0.6 12.6 9.1 11.5 0.7 13 9.5 26 4 22 305 6.1 0 6.4 5.9 09/29/2005 12:20:00 10.9 0.6 12.2 9.1 11 0.7 13 9.1 24 4 19 305 6 0 6.1 5.9 09/29/2005 12:30:00 10.5 0.7 12.2 8.8 10.5 0.8 12.2 7.6 26 4 30 305 6 0 6.1 5.9 09/29/2005 12:40:00 11.1 0.6 12.6 9.5 11.1 0.8 12.6 8.4 24 4 21 305 6 0 6.1 5.9 09/29/2005 12:50:00 11.3 0.7 12.6 8.8 11.3 0.8 12.6 8.8 25 4 27 305 6 0 6.1 5.9 09/29/2005 13:00:00 11.4 0.8 12.6 9.1 11.5 0.9 13 9.1 26 4 28 305 6 0 6.4 5.9 09/29/2005 13:10:00 11.6 0.8 13.3 8.8 11.5 0.9 13.3 8.8 28 4 35 305 6.1 0 6.4 5.9 09/29/2005 13:20:00 11.6 0.6 13.3 9.9 11.5 0.6 13 9.1 31 4 33 305 6.3 0 6.4 6.1 09/29/2005 13:30:00 11.7 0.7 13.3 9.9 11.6 0.8 13 8.8 31 3 31 305 6.3 0 6.4 6.1 09/29/2005 13:40:00 11.3 0.8 13 9.1 11.3 0.8 13 9.1 31 4 33 305 6.3 0 6.4 6.1 09/29/2005 13:50:00 11.2 0.9 12.6 8.4 11.2 0.9 13 8.4 30 3 29 305 6.2 0 6.4 6.1 09/29/2005 14:00:00 11.3 0.8 13 9.1 11.2 0.9 13.3 8.8 33 4 28 305 6.4 0 6.7 6.1 09/29/2005 14:10:00 11.5 0.7 13 9.5 11.4 0.7 13 9.5 32 3 31 305 6.6 0 6.9 6.1 09/29/2005 14:20:00 11.4 1 13.3 8.8 11.3 1 13.3 8.4 32 4 32 305 6.6 0 6.9 6.4 09/29/2005 14:30:00 11 0.9 12.6 8.4 10.9 1 13 8 33 4 31 305 6.7 0 6.9 6.4 09/29/2005 14:40:00 10.6 0.7 12.2 8.4 10.6 0.8 12.6 8 30 4 31 305 6.6 0 6.9 6.4 09/29/2005 14:50:00 10.7 0.8 12.2 8.4 10.7 0.9 12.6 8 27 4 22 305 6.7 0.1 6.9 6.4 09/29/2005 15:00:00 10.9 0.6 12.2 9.1 11 0.6 12.6 9.5 22 4 29 305 6.3 0 6.7 6.1 09/29/2005 15:10:00 10.4 0.8 12.2 8.4 10.5 1 12.2 8 18 3 19 305 6.3 0 6.4 6.1 09/29/2005 15:20:00 10.7 0.7 12.2 8.8 10.7 0.8 12.2 8.8 16 4 14 305 6.1 0 6.4 5.9 09/29/2005 15:30:00 10.9 0.9 12.2 8.4 11 1 12.6 8.4 11 4 9 305 6 0.1 6.4 5.9 09/29/2005 15:40:00 10.7 0.8 12.6 8.8 10.8 0.8 13 8.8 15 5 13 305 6 0 6.1 5.9 09/29/2005 15:50:00 11.1 0.7 12.6 8.4 11.3 0.8 13.3 9.1 15 4 12 305 6 0 6.1 5.9 09/29/2005 16:00:00 11.5 0.6 13 9.5 11.6 0.8 13.3 8.8 15 3 18 305 5.9 0 6.1 5.9 09/29/2005 16:10:00 11.6 0.7 13 9.1 11.8 0.7 13.3 9.1 13 4 15 305 5.9 0 6.1 5.9 09/29/2005 16:20:00 11.6 0.7 13 9.1 11.7 0.7 13.3 8.8 14 3 20 305 5.9 0 6.1 5.9 09/29/2005 16:30:00 11.7 0.6 13 9.9 11.9 0.7 13.3 9.9 16 3 19 305 6 0 6.1 5.9 09/29/2005 16:40:00 11 0.9 13 8.8 11 1 13.3 8.8 18 3 18 305 6 0 6.1 5.9 09/29/2005 16:50:00 11 0.6 12.2 8.8 11.1 0.7 12.6 8.8 17 3 15 305 6 0 6.1 5.9 09/29/2005 17:00:00 10.7 0.8 12.2 8 10.9 0.9 12.6 8 23 4 17 305 6 0 6.1 5.9 09/29/2005 17:10:00 10.4 0.7 11.8 8.4 10.5 0.7 12.2 8.4 22 3 21 305 6 0 6.1 5.9 09/29/2005 17:20:00 9.5 0.7 11.1 7.6 9.4 0.8 11.5 7.2 26 5 28 305 6.2 0 6.4 5.9 09/29/2005 17:30:00 10.2 0.6 11.5 8.4 10.2 0.6 11.8 8.4 24 4 27 305 6.2 0 6.4 5.9 09/29/2005 17:40:00 10.3 0.6 11.5 8.4 10.4 0.7 11.8 8.4 24 3 23 305 6.2 0 6.4 6.1 09/29/2005 17:50:00 10.2 0.8 11.8 7.6 10.3 0.9 12.2 7.2 21 4 29 305 6.1 0.1 6.4 5.9 09/29/2005 18:00:00 10.1 0.8 11.8 8 10.2 0.9 12.2 8.4 22 4 17 305 5.8 0 5.9 5.6 09/29/2005 18:10:00 11 0.8 12.2 8.4 11 0.9 12.6 8 25 4 21 305 5.5 0 5.9 5.4 09/29/2005 18:20:00 10.6 0.7 12.2 8.8 10.6 0.9 13 8.4 27 4 26 305 5.6 0 5.9 5.4 09/29/2005 18:30:00 11.3 0.7 13 8.8 11.3 0.9 13 8.4 27 3 27 305 5.6 0 5.6 5.4 09/29/2005 18:40:00 11.3 0.8 12.6 8.4 11.3 0.8 13 8 28 4 32 305 5.6 0 5.6 5.4 09/29/2005 18:50:00 11.7 0.7 13.3 9.5 11.5 0.8 13.3 9.5 29 4 25 305 5.4 0 5.6 5.4 09/29/2005 19:00:00 12.1 0.6 13.3 9.9 12 0.7 14.1 9.1 28 3 23 305 5.3 0 5.6 5.2 09/29/2005 19:10:00 12 0.9 14.1 9.5 11.9 1 14.1 9.1 30 4 26 305 5.2 0 5.4 4.9 09/29/2005 19:20:00 12.3 0.7 13.7 10.3 12.3 0.8 13.7 9.9 33 3 31 305 5 0 5.2 4.9 09/29/2005 19:30:00 12.1 0.9 14.1 9.9 12 1 14.1 9.1 29 5 25 305 4.8 0 5.2 4.9 09/29/2005 19:40:00 12.5 0.6 13.7 10.7 12.3 0.7 13.7 10.3 31 3 25 305 4.8 0 4.9 4.7 09/29/2005 19:50:00 11.6 0.8 13.3 9.1 11.4 0.9 13.3 9.1 32 4 31 305 4.8 0 4.9 4.9 09/29/2005 20:00:00 12.7 0.9 14.5 9.9 12.6 0.8 14.5 10.3 29 3 29 305 4.8 0 4.9 4.7 09/29/2005 20:10:00 12.8 0.6 14.5 11.5 12.7 0.8 14.5 10.3 33 4 35 305 4.8 0 4.9 4.7 09/29/2005 20:20:00 12.5 0.8 14.1 10.3 12.3 1 14.1 9.5 32 3 32 305 4.8 0 4.9 4.7 09/29/2005 20:30:00 11.8 0.8 14.1 9.5 11.8 0.9 13.7 9.1 29 4 24 305 4.8 0 4.9 4.7 09/29/2005 20:40:00 11.6 0.7 13.3 8.8 11.5 0.8 13.3 8.4 27 5 27 305 4.8 0 4.9 4.7 09/29/2005 20:50:00 10.7 0.7 12.6 9.1 10.8 0.8 13 8.8 22 4 22 305 4.6 0 4.9 4.4 09/29/2005 21:00:00 10.7 0.6 12.2 8.8 10.7 0.7 12.6 8.8 29 3 23 305 4.5 0 4.7 4.4 09/29/2005 21:10:00 10.8 0.9 13 8.8 10.8 0.9 13 8.8 30 4 29 305 4.4 0 4.7 4.4 09/29/2005 21:20:00 11.4 0.7 13 9.5 11.3 0.7 13 9.1 31 4 33 305 4.5 0 4.7 4.4 09/29/2005 21:30:00 11.4 0.6 13 9.5 11.4 0.7 13 9.1 33 4 33 305 4.4 0 4.7 4.4 09/29/2005 21:40:00 10.8 0.8 12.2 8.8 10.7 0.9 12.2 8 32 4 36 305 4.4 0 4.7 4.4 09/29/2005 21:50:00 11.1 0.8 13 9.1 11 0.9 12.6 8.4 29 4 28 305 4.5 0 4.7 4.4 09/29/2005 22:00:00 11.2 0.8 13 8.4 11.2 0.8 13 8.8 26 5 22 305 4.5 0 4.7 4.4 09/29/2005 22:10:00 10.6 0.7 12.2 9.1 10.7 0.7 12.6 9.1 24 5 24 305 4.5 0 4.7 4.4 09/29/2005 22:20:00 10.8 0.6 12.2 9.1 10.9 0.7 12.6 8.8 25 5 28 305 4.4 0 4.7 4.4 09/29/2005 22:30:00 10.3 0.6 11.8 8.4 10.3 0.7 12.2 8.4 27 5 33 305 4.4 0 4.7 4.4 09/29/2005 22:40:00 11.3 0.8 13.7 9.1 11.4 0.9 13.7 8.8 27 5 21 305 4.5 0 4.7 4.4 09/29/2005 22:50:00 10.8 0.7 13 8.8 10.9 0.8 13 8.4 18 4 14 305 4.5 0 4.7 4.4 09/29/2005 23:00:00 11.5 0.9 14.1 9.1 11.6 0.9 14.1 9.5 17 5 16 305 4.5 0 4.7 4.4 09/29/2005 23:10:00 11.7 0.6 13.3 9.9 11.9 0.7 13.7 9.9 16 5 18 305 4.5 0 4.7 4.4 09/29/2005 23:20:00 11.8 1 13.3 8.8 12 1 14.5 8.8 18 5 24 305 4.5 0 4.9 4.4 09/29/2005 23:30:00 11.5 0.8 13.3 8.8 11.7 0.9 13.3 8.4 17 4 20 305 4.5 0 4.7 4.4 09/29/2005 23:40:00 11.2 0.6 12.6 9.1 11.3 0.6 13 9.5 17 5 28 305 4.4 0 4.7 4.4 09/29/2005 23:50:00 11.4 0.7 13 9.5 11.6 0.8 13.3 9.5 19 4 22 305 4.3 0 4.4 4.2 09/30/2005 00:00:00 11.5 0.7 13 9.5 11.7 0.8 13.3 8.8 16 4 22 305 4.3 0 4.7 4.2 09/30/2005 00:10:00 11.4 0.7 13 9.1 11.7 0.8 13.3 9.5 16 3 15 305 4.2 0 4.4 4.2 09/30/2005 00:20:00 11.2 0.8 13 9.1 11.3 1 13 8.8 16 6 23 305 4.2 0 4.4 4.2 09/30/2005 00:30:00 11.3 0.8 13 9.1 11.4 0.8 13 9.1 17 4 18 305 4.3 0 4.7 4.2 09/30/2005 00:40:00 11.3 0.9 13 9.1 11.3 1 13.7 8.8 21 5 28 305 4.2 0 4.4 4.2 09/30/2005 00:50:00 11.5 0.8 13 9.1 11.6 1 13.3 8.8 18 4 21 305 4.3 0 4.4 4.2 09/30/2005 01:00:00 11.9 0.6 13 9.9 12 0.7 13.7 10.3 17 4 28 305 4.3 0 4.7 4.2 09/30/2005 01:10:00 11.8 0.7 13.3 9.5 11.9 0.8 13.7 9.1 14 3 13 305 4.3 0 4.4 4.2 09/30/2005 01:20:00 11.8 0.5 13.3 10.3 11.9 0.6 13.3 9.5 18 3 15 305 4.3 0 4.7 4.2 09/30/2005 01:30:00 12 0.7 13.3 9.1 12.1 0.8 13.3 9.1 18 4 17 305 4.3 0 4.7 4.2 09/30/2005 01:40:00 11.4 0.7 13 9.5 11.5 0.8 13.3 9.1 17 4 17 305 4.3 0 4.7 4.2 09/30/2005 01:50:00 11.3 0.7 13 9.5 11.4 0.8 13 9.1 18 4 16 305 4.3 0 4.7 4.2 09/30/2005 02:00:00 11.2 0.7 12.6 9.1 11.3 0.8 13 9.1 17 5 12 305 4.3 0 4.7 4.2 09/30/2005 02:10:00 10.9 0.6 12.6 8.8 11.1 0.7 13 8.8 13 5 5 305 4.3 0 4.7 4.2 09/30/2005 02:20:00 10.6 0.7 12.2 8.4 10.8 0.8 12.6 8.4 12 4 7 305 4.3 0 4.7 4.2 09/30/2005 02:30:00 10.8 0.8 12.2 8.4 11 0.9 13 8.4 8 5 11 305 4.3 0 4.7 4.2 09/30/2005 02:40:00 10.2 0.7 11.8 8.4 10.4 0.8 12.6 8.4 4 4 1 305 4.4 0 4.7 4.2 09/30/2005 02:50:00 10.4 0.6 12.2 8.4 10.7 0.7 11.8 8.4 6 4 4 305 4.3 0 4.7 4.2 09/30/2005 03:00:00 10.2 0.7 11.8 8.4 10.4 0.8 12.2 7.6 6 5 8 305 4.4 0 4.7 4.2 09/30/2005 03:10:00 10.2 0.7 12.2 8 10.5 0.8 12.2 7.6 5 4 7 305 4.4 0 4.7 4.2 09/30/2005 03:20:00 10.4 0.7 11.8 8.8 10.6 0.8 12.6 8.4 4 4 2 305 4.4 0 4.7 4.4 09/30/2005 03:30:00 11.2 1 13.3 8.8 11.4 1 13.7 8.8 8 4 15 305 4.3 0 4.7 4.2 09/30/2005 03:40:00 11.7 0.8 13.7 9.5 11.9 0.8 13.7 9.5 11 4 9 305 4.3 0 4.7 4.2 09/30/2005 03:50:00 11.6 1 13.3 8.8 11.8 1.1 13.7 9.1 10 4 7 305 4.1 0 4.4 4.2 09/30/2005 04:00:00 11.6 0.8 13.3 9.5 11.8 0.9 14.1 9.1 14 4 12 305 4.2 0 4.7 4.2 09/30/2005 04:10:00 12.4 0.8 14.1 10.3 12.6 0.9 14.1 9.9 8 3 14 305 4.3 0 4.7 4.2 09/30/2005 04:20:00 12.3 0.9 14.1 9.5 12.6 0.9 14.5 10.3 6 4 8 305 4.2 0.1 4.7 3.9 09/30/2005 04:30:00 11.7 0.7 13.3 9.5 11.9 0.8 13.7 9.1 5 4 4 305 4 0.1 4.4 3.7 09/30/2005 04:40:00 11.5 0.8 13.3 9.1 11.8 0.9 13.3 9.1 2 5 2 305 3.9 0.1 4.4 3.7 09/30/2005 04:50:00 11.5 1 13.3 8.8 11.8 1 13.7 8.4 4 3 2 305 3.9 0.1 4.4 3.7 09/30/2005 05:00:00 11.7 0.7 13.3 9.1 11.9 0.7 13.3 9.5 0 4 2 305 3.9 0.1 4.4 3.7 09/30/2005 05:10:00 11.5 0.8 13.3 9.5 11.8 0.8 13.7 9.1 2 4 3 305 3.8 0 4.4 3.7 09/30/2005 05:20:00 11.6 0.8 13.7 9.1 11.8 0.8 14.1 9.1 3 4 359 305 3.8 0 4.2 3.7 09/30/2005 05:30:00 11.1 0.6 12.2 9.1 11.4 0.8 12.6 8.8 359 4 357 305 3.7 0 4.2 3.7 09/30/2005 05:40:00 11.2 0.8 13 9.1 11.4 1 13.3 8.8 359 4 359 305 3.8 0 4.2 3.7 09/30/2005 05:50:00 11.1 0.8 13 8.4 11.4 0.8 13.3 9.1 1 5 357 305 3.7 0 4.2 3.4 09/30/2005 06:00:00 10.9 0.7 12.6 8.8 11.2 0.8 13.3 8.8 0 3 356 305 3.7 0 4.2 3.4 09/30/2005 06:10:00 10.9 0.7 12.6 8.8 11.2 0.8 13 8.8 0 4 7 305 3.7 0 4.2 3.4 09/30/2005 06:20:00 11 0.7 12.6 8.8 11.3 0.8 13 8.4 359 5 2 305 3.7 0 4.2 3.7 09/30/2005 06:30:00 11.6 0.7 13 8.8 11.8 0.8 13.7 8.8 2 5 359 305 3.7 0 4.2 3.4 09/30/2005 06:40:00 11 1 13 8.8 11.2 1.1 13.3 8 1 5 2 305 3.7 0 4.2 3.4 09/30/2005 06:50:00 10.9 0.7 12.6 8.8 11.2 0.8 13 9.1 359 5 2 305 3.7 0 4.2 3.4 09/30/2005 07:00:00 10.6 0.8 12.2 7.6 10.9 0.8 12.6 8 359 5 351 305 3.8 0 4.2 3.7 09/30/2005 07:10:00 11 0.9 13 8.8 11.3 0.9 13 8.8 0 4 358 305 3.8 0 4.2 3.4 09/30/2005 07:20:00 11.3 0.9 13 8.8 11.7 1 13.3 9.1 356 4 358 305 3.7 0 4.2 3.4 09/30/2005 07:30:00 11.4 0.9 13.3 8.4 11.6 1 13.7 8.8 354 4 356 305 3.7 0 4.2 3.4 09/30/2005 07:40:00 10.7 0.7 12.2 8 11 0.8 12.6 8 355 3 0 305 3.7 0 4.2 3.4 09/30/2005 07:50:00 10.7 0.8 13.7 7.2 10.9 0.9 13.3 7.6 354 5 340 305 3.7 0 4.2 3.4 09/30/2005 08:00:00 11.4 0.7 13.3 9.5 11.8 0.8 14.1 9.5 353 5 356 305 3.6 0.1 3.9 3.4 09/30/2005 08:10:00 11 0.8 12.6 8.4 11.3 1 13.3 7.6 353 6 352 305 3.6 0 4.2 3.4 09/30/2005 08:20:00 11.4 0.9 13.3 8.8 11.7 1 13.7 8.4 353 4 353 305 3.7 0 4.2 3.4 09/30/2005 08:30:00 10.9 0.8 13 8 11.2 1 13.3 8 355 3 355 305 3.7 0 4.2 3.4 09/30/2005 08:40:00 11.5 0.8 13 9.5 11.8 0.8 13.3 9.5 7 6 8 305 3.8 0.1 4.4 3.7 09/30/2005 08:50:00 11.7 1 13.7 9.5 12 1 14.1 9.5 357 5 5 305 3.1 0.3 3.9 2.7 09/30/2005 09:00:00 11.4 0.9 13.3 8.4 11.8 1 13.7 8.4 350 4 352 305 2.6 0 3.2 2.5 09/30/2005 09:10:00 11.7 0.7 13.3 9.5 12.1 0.8 14.1 9.5 345 3 348 305 2.7 0 3.2 2.5 09/30/2005 09:20:00 11.3 1 13.3 9.1 11.6 1.1 14.1 9.5 344 4 343 305 2.7 0.1 3.2 2.5 09/30/2005 09:30:00 10.7 0.7 12.2 8.8 11 0.8 12.6 8.4 342 3 341 305 2.7 0 3.2 2.5 09/30/2005 09:40:00 9.9 0.6 11.5 7.6 10.3 0.7 11.8 8 339 3 339 305 2.8 0.1 3.2 2.7 09/30/2005 09:50:00 9.1 0.9 11.5 7.2 9.3 0.9 11.5 7.2 352 9 359 305 3 0.1 3.7 2.7 09/30/2005 10:00:00 10.4 0.9 12.2 8 10.6 1 12.6 7.6 11 4 12 305 3.4 0.1 3.9 3.2 09/30/2005 10:10:00 9.8 0.9 11.8 7.2 10 1 12.2 7.2 10 5 10 305 3.5 0.1 3.9 3.2 09/30/2005 10:20:00 9.3 0.7 11.1 7.2 9.6 0.8 11.8 7.6 6 6 1 305 3.5 0.1 3.9 3.2 09/30/2005 10:30:00 9.1 0.8 11.1 7.2 9.4 0.8 11.5 7.2 5 5 5 305 3.5 0.1 3.9 3.4 09/30/2005 10:40:00 9.9 1.1 12.6 7.6 10.3 1.1 13 8 13 5 12 305 3.5 0.2 3.9 3.2 09/30/2005 10:50:00 10.2 1.1 12.6 7.6 10.4 1.1 13 7.6 12 4 13 305 3.3 0.1 3.7 3.2 09/30/2005 11:00:00 10.3 1.2 13 8 10.5 1.2 13 7.6 9 5 11 305 3.3 0 3.7 3.2 09/30/2005 11:10:00 10.1 0.9 13 7.6 10.3 0.9 13 8.4 10 4 24 305 3.3 0 3.7 3.2 09/30/2005 11:20:00 9.6 1 11.8 7.2 9.8 1.1 12.2 7.6 9 7 14 305 3.3 0.1 3.7 3.2 09/30/2005 11:30:00 9.6 0.7 11.5 7.6 9.9 0.9 11.8 7.2 7 7 3 305 3.3 0.1 3.7 3.2 09/30/2005 11:40:00 9.3 0.8 11.1 6.8 9.6 0.8 11.5 6.5 4 6 8 305 3.3 0.1 3.7 3.2 09/30/2005 11:50:00 9.9 0.8 12.2 7.6 10.2 0.8 12.6 8.4 4 5 14 305 3.4 0.1 3.7 3.2 09/30/2005 12:00:00 10.2 0.8 12.2 8 10.5 0.8 12.6 8.4 8 5 5 305 3.4 0.1 3.9 3.2 09/30/2005 12:10:00 10.1 0.7 11.5 8.4 10.4 0.8 12.2 8.4 3 5 9 305 3.4 0.1 3.9 3.2 09/30/2005 12:20:00 10.2 0.7 11.8 8.4 10.5 0.8 12.6 8.8 5 6 355 305 3.3 0.1 3.7 3.2 09/30/2005 12:30:00 10.7 0.7 12.6 8.4 11 0.8 13 8.4 4 4 2 305 3.2 0 3.7 2.9 09/30/2005 12:40:00 10.9 0.8 12.6 8.8 11.2 0.8 13.3 9.1 5 5 4 305 3.3 0 3.7 2.9 09/30/2005 12:50:00 10.6 0.8 12.2 7.6 10.9 0.9 12.6 7.6 6 5 5 305 3.2 0 3.7 2.9 09/30/2005 13:00:00 10.1 0.6 11.8 8 10.4 0.7 12.2 8.4 9 3 7 305 3.3 0 3.7 3.2 09/30/2005 13:10:00 9.6 0.5 10.7 8 9.9 0.6 11.5 8.4 4 5 9 305 3.3 0 3.7 2.9 09/30/2005 13:20:00 10.1 1 12.6 7.6 10.3 1 12.6 8 15 7 356 305 3.3 0 3.7 2.9 09/30/2005 13:30:00 10.3 0.7 12.2 8.8 10.6 0.8 12.6 8.4 4 4 10 305 3.3 0 3.7 3.2 09/30/2005 13:40:00 10.1 1.2 13 7.2 10.4 1.2 13 7.2 5 6 7 305 3.1 0.1 3.7 2.9 09/30/2005 13:50:00 9.5 0.8 12.2 7.6 9.8 0.8 12.2 7.6 7 5 4 305 3.1 0 3.4 2.9 09/30/2005 14:00:00 10 1 12.6 8 10.3 1 12.6 8 6 5 13 305 3.2 0 3.7 2.9 09/30/2005 14:10:00 11.3 0.7 13.3 8.8 11.6 0.8 13.7 9.1 4 4 9 305 3.2 0 3.7 2.9 09/30/2005 14:20:00 10.4 0.9 12.2 8 10.6 0.9 12.6 8.4 12 7 19 305 3.2 0 3.7 2.9 09/30/2005 14:30:00 11.7 1.2 14.9 9.1 12 1.2 14.9 9.1 6 4 358 305 3.2 0 3.7 2.9 09/30/2005 14:40:00 11.1 1.3 13.7 8 11.4 1.5 14.1 7.6 7 7 356 305 3.1 0 3.7 2.9 09/30/2005 14:50:00 10.9 1.5 14.9 8 11.2 1.5 15.3 8.4 10 6 9 305 3.2 0 3.7 2.9 09/30/2005 15:00:00 10.7 1 13 8.8 10.9 1 13 8.8 13 5 8 305 3.2 0 3.7 2.9 09/30/2005 15:10:00 11.2 0.8 13.7 9.1 11.3 1 13.7 9.1 11 5 4 305 3.3 0 3.7 2.9 09/30/2005 15:20:00 11.3 1.3 14.9 8.4 11.4 1.4 14.9 8.8 15 6 11 305 3.2 0 3.7 2.9 09/30/2005 15:30:00 11.7 1.3 14.5 8.8 11.9 1.4 14.5 9.1 14 5 17 305 3.2 0 3.7 2.9 09/30/2005 15:40:00 11.5 1.1 14.1 8.8 11.7 1.2 14.5 8.8 17 4 10 305 3.3 0 3.7 2.9 09/30/2005 15:50:00 11.7 1 13.7 8.8 11.9 1.1 14.1 9.1 18 4 21 305 3.1 0 3.7 2.9 09/30/2005 16:00:00 11.9 0.8 13.7 9.5 12 1 13.7 8.4 14 5 14 305 3.2 0 3.7 2.9 09/30/2005 16:10:00 10.4 0.8 13.3 8.8 10.7 0.8 13 8.8 11 6 2 305 3.1 0 3.4 2.9 09/30/2005 16:20:00 10.5 1 12.6 7.6 10.7 1 13.3 7.2 7 5 6 305 3.1 0 3.4 2.9 09/30/2005 16:30:00 10.5 1 13 8 10.8 1 14.1 8 3 6 5 305 3.1 0.1 3.7 2.9 09/30/2005 16:40:00 10.8 0.8 12.6 8.4 11 1 13 8.4 16 7 13 305 3.1 0.1 3.7 2.9 09/30/2005 16:50:00 10.8 1 13.3 8 10.9 1 13.7 8 16 5 10 305 3 0 3.4 2.9 09/30/2005 17:00:00 10.4 0.9 12.6 8.4 10.5 1 13 8.4 19 7 17 305 3.1 0.1 3.4 2.9 09/30/2005 17:10:00 10.5 1 12.6 7.6 10.7 1 13 7.6 16 4 19 305 3 0.1 3.4 2.7 09/30/2005 17:20:00 10.8 0.9 13 8.4 11 0.9 13 8.8 14 5 21 305 2.8 0.2 3.4 2.7 09/30/2005 17:30:00 9.3 1 12.6 6.8 9.7 1.1 13 6.8 7 6 5 305 2.8 0.2 3.4 2.7 09/30/2005 17:40:00 9 0.7 11.1 7.2 9.3 0.7 11.5 7.6 2 5 9 305 2.8 0.2 3.4 2.7 09/30/2005 17:50:00 9 1 11.8 6.8 9.3 0.9 11.8 7.2 9 4 16 305 2.9 0.1 3.4 2.7 09/30/2005 18:00:00 9.8 1.1 12.2 7.2 10 1.1 12.6 7.6 6 5 355 305 3 0.1 3.4 2.7 09/30/2005 18:10:00 8.7 0.6 10.3 6.8 9 0.7 10.7 6.8 8 6 5 305 3.1 0.1 3.4 2.9 09/30/2005 18:20:00 9.3 0.8 11.1 7.2 9.5 0.9 11.8 6.8 9 5 14 305 3.1 0 3.7 2.9 09/30/2005 18:30:00 10 0.8 12.6 8.4 10.2 0.9 13 8.4 14 6 4 305 3 0.1 3.4 2.7 09/30/2005 18:40:00 9.9 0.9 11.8 7.6 10 0.9 12.2 8 17 5 19 305 3 0.1 3.4 2.9 09/30/2005 18:50:00 10 0.8 11.8 7.6 10.2 0.8 12.2 7.6 21 5 22 305 2.9 0.1 3.4 2.7 09/30/2005 19:00:00 9.9 1 12.2 7.2 10.1 1 13 7.2 14 5 25 305 3 0.1 3.4 2.9 09/30/2005 19:10:00 9.2 0.8 12.2 7.2 9.3 0.8 11.8 6.8 20 7 33 305 3 0.2 3.4 2.7 09/30/2005 19:20:00 9.9 0.7 11.5 7.6 10 0.7 11.8 8 20 4 16 305 2.9 0.1 3.4 2.7 09/30/2005 19:30:00 9.7 0.9 11.8 7.2 9.8 0.9 11.8 6.8 20 4 16 305 2.9 0.1 3.4 2.7 09/30/2005 19:40:00 9.9 0.8 11.8 7.2 10.1 0.8 12.2 8 19 5 28 305 2.9 0.1 3.4 2.7 09/30/2005 19:50:00 9.7 1 11.8 7.6 9.8 1 12.2 7.6 21 5 19 305 2.8 0.1 3.2 2.7 09/30/2005 20:00:00 8.9 0.9 11.8 6.5 9.1 0.9 11.8 6.5 18 5 29 305 2.8 0.1 3.4 2.7 09/30/2005 20:10:00 8.5 0.9 10.7 6.5 8.8 0.9 11.1 6.1 16 6 18 305 2.9 0.1 3.4 2.7 09/30/2005 20:20:00 8.4 1 11.1 5.7 8.6 1 11.1 5.7 8 8 15 305 3 0 3.4 2.7 09/30/2005 20:30:00 7.7 0.7 9.9 6.1 7.9 0.7 9.9 6.1 12 5 9 305 2.9 0.1 3.4 2.7 09/30/2005 20:40:00 6.7 0.7 8.8 4.9 7 0.8 9.1 5.3 9 6 10 305 2.8 0.1 3.4 2.7 09/30/2005 20:50:00 7.2 0.5 9.1 6.1 7.5 0.5 9.5 6.5 14 6 22 305 2.9 0.1 3.4 2.7 09/30/2005 21:00:00 7.7 0.9 10.7 5.7 7.9 0.9 11.1 6.1 13 6 9 305 3 0.1 3.4 2.7 09/30/2005 21:10:00 8.3 1 10.3 5.7 8.7 1 10.7 6.5 3 5 4 305 3 0.1 3.4 2.7 09/30/2005 21:20:00 8 1 9.9 5.7 8.3 1 10.7 5.7 9 6 15 305 3 0.1 3.4 2.7 09/30/2005 21:30:00 8.4 0.8 10.3 6.1 8.7 0.8 10.3 6.5 11 3 11 305 2.9 0.1 3.4 2.9 09/30/2005 21:40:00 7.4 0.8 9.5 5.7 7.8 0.8 9.5 5.7 6 9 9 305 2.9 0.1 3.4 2.7 09/30/2005 21:50:00 8.2 0.9 11.1 6.1 8.5 0.9 11.5 6.5 6 6 359 305 2.9 0.2 3.4 2.7 09/30/2005 22:00:00 8.1 0.8 10.7 6.5 8.4 0.9 10.3 6.5 13 4 18 305 2.9 0.2 3.4 2.7 09/30/2005 22:10:00 8.4 0.8 10.3 5.7 8.7 0.9 11.1 6.8 4 8 2 305 2.9 0.2 3.4 2.7 09/30/2005 22:20:00 6.8 1.2 9.5 4.2 7.1 1.3 10.3 4.6 359 4 5 305 2.9 0.2 3.4 2.7 09/30/2005 22:30:00 7.6 0.7 9.1 5.7 7.9 0.8 9.9 6.1 4 7 0 305 2.9 0.2 3.4 2.7 09/30/2005 22:40:00 8 0.9 10.7 5.7 8.4 0.8 10.7 6.1 0 7 6 305 2.9 0.2 3.4 2.7 09/30/2005 22:50:00 8.7 0.8 11.1 6.8 8.9 0.9 11.1 6.8 4 6 12 305 2.9 0.2 3.4 2.7 09/30/2005 23:00:00 7.2 0.8 9.1 5.3 7.5 0.8 9.1 5.3 7 6 13 305 2.8 0.2 3.2 2.7 09/30/2005 23:10:00 8.1 1 10.3 5.7 8.4 1 11.5 6.1 353 6 356 305 2.9 0.2 3.4 2.7 09/30/2005 23:20:00 6.3 0.9 9.1 4.2 6.7 0.9 9.1 4.6 0 8 357 305 2.9 0.2 3.4 2.7 09/30/2005 23:30:00 7.1 1.5 10.3 4.9 7.4 1.3 10.7 5.3 2 7 8 305 3 0.2 3.4 2.9 09/30/2005 23:40:00 7.3 1.2 9.5 4.2 7.6 1.2 9.9 4.6 13 8 13 305 2.9 0.2 3.4 2.7 09/30/2005 23:50:00 7.9 0.8 9.5 5.7 8.2 0.8 9.9 6.5 8 6 12 305 2.8 0.2 3.4 2.7 10/01/2005 00:00:00 7.9 0.8 10.3 6.1 8.3 0.8 10.7 6.1 9 9 5 305 2.8 0.1 3.2 2.5 10/01/2005 00:10:00 6.4 0.8 8.8 4.9 6.8 0.8 9.1 4.9 355 9 351 305 2.8 0.1 3.2 2.5 10/01/2005 00:20:00 7.4 0.9 10.3 4.9 7.7 0.9 10.7 5.3 18 10 28 305 2.8 0.1 3.2 2.7 10/01/2005 00:30:00 7 1.1 9.9 4.9 7.4 1.2 10.7 4.9 351 8 352 305 2.7 0 3.2 2.5 10/01/2005 00:40:00 6.9 1.1 9.5 4.9 7.2 1.1 9.9 4.9 8 7 0 305 2.7 0.1 3.2 2.7 10/01/2005 00:50:00 7.9 1.3 10.3 5.3 8.2 1.3 10.7 5.7 4 12 0 305 2.7 0.1 3.2 2.5 10/01/2005 01:00:00 6.9 1.1 8.8 4.2 7.3 1 9.1 4.6 8 7 17 305 2.8 0.1 3.2 2.7 10/01/2005 01:10:00 7.6 0.9 9.5 5.3 7.9 1 10.3 5.7 13 7 12 305 2.8 0.1 3.2 2.5 10/01/2005 01:20:00 7.7 0.6 9.5 6.1 8.1 0.6 9.9 6.5 10 8 10 305 2.8 0.1 3.2 2.5 10/01/2005 01:30:00 7.7 0.8 9.9 6.1 8 0.8 9.9 6.1 10 5 1 305 2.8 0.1 3.2 2.5 10/01/2005 01:40:00 6.6 0.9 9.1 4.9 7.1 0.8 9.5 5.3 8 15 17 305 2.6 0.1 3.2 2.5 10/01/2005 01:50:00 6.3 0.9 8.4 4.2 6.6 0.9 8.8 4.6 0 7 7 305 2.7 0.1 3.2 2.5 10/01/2005 02:00:00 7.2 1 9.5 4.9 7.5 1 10.3 4.9 7 7 11 305 2.7 0.1 3.2 2.5 10/01/2005 02:10:00 7.2 1.2 9.5 4.6 7.5 1.2 9.9 4.9 4 6 358 305 2.7 0 3.2 2.5 10/01/2005 02:20:00 7.2 1 9.5 5.3 7.6 1 9.9 5.3 2 6 358 305 2.7 0 3.2 2.5 10/01/2005 02:30:00 7.1 1.1 9.5 4.6 7.4 1.1 9.9 4.9 2 5 6 305 2.6 0 3.2 2.5 10/01/2005 02:40:00 6.9 1.1 9.5 4.9 7.2 1.1 9.9 5.3 357 8 8 305 2.6 0 3.2 2.5 10/01/2005 02:50:00 6.7 0.6 8.4 5.3 7.1 0.6 8.8 6.1 358 5 358 305 2.6 0 3.2 2.5 10/01/2005 03:00:00 7.4 0.7 8.8 5.3 7.8 0.8 9.1 5.7 3 4 4 305 2.6 0 3.2 2.5 10/01/2005 03:10:00 6.6 0.7 9.1 5.3 7 0.6 9.5 5.7 349 7 348 305 2.6 0 3.2 2.5 10/01/2005 03:20:00 6.3 1.1 9.1 4.6 6.8 1.1 9.5 4.6 355 6 351 305 2.6 0 3.2 2.5 10/01/2005 03:30:00 6.6 0.9 9.1 4.6 6.9 0.9 9.9 5.3 351 9 2 305 2.5 0 2.9 2.2 10/01/2005 03:40:00 7.1 0.9 9.5 4.9 7.4 0.9 9.9 5.3 355 7 353 305 2.5 0 2.9 2.2 10/01/2005 03:50:00 6.9 0.6 8.8 5.7 7.2 0.7 9.1 4.9 359 6 9 305 2.5 0 2.9 2.5 10/01/2005 04:00:00 7.5 0.7 9.9 5.7 7.8 0.7 9.9 6.1 5 6 3 305 2.5 0 2.9 2.2 10/01/2005 04:10:00 7.4 0.7 9.1 5.7 7.8 0.7 9.1 6.1 1 6 4 305 2.5 0 2.7 2.2 10/01/2005 04:20:00 6.9 0.8 9.1 4.9 7.2 0.7 9.5 5.7 8 6 7 305 2.4 0.1 2.7 2.2 10/01/2005 04:30:00 6.9 0.9 9.5 4.9 7.2 1 9.9 5.7 11 5 9 305 2.5 0.1 2.7 2.2 10/01/2005 04:40:00 8.1 0.7 10.7 6.5 8.5 0.7 10.7 6.8 9 4 11 305 2.4 0.1 2.7 2.2 10/01/2005 04:50:00 7.1 0.7 8.8 5.7 7.4 0.7 9.5 5.7 4 5 4 305 2.5 0.1 2.9 2.2 10/01/2005 05:00:00 7.8 1 9.9 5.7 8.1 1 10.3 5.7 346 8 332 305 2.5 0 2.9 2.2 10/01/2005 05:10:00 6.8 1.4 10.3 4.6 7.2 1.5 10.7 4.9 4 16 341 305 2.4 0.1 2.7 2.2 10/01/2005 05:20:00 6.3 0.6 8 4.9 6.7 0.6 8.4 5.3 15 8 9 305 2.5 0 2.7 2.2 10/01/2005 05:30:00 6 0.5 7.6 4.6 6.3 0.5 7.6 5.3 16 6 359 305 2.5 0 2.9 2.2 10/01/2005 05:40:00 6.3 0.6 8.4 4.9 6.7 0.6 9.1 5.3 12 6 5 305 2.5 0 2.9 2.5 10/01/2005 05:50:00 6.3 0.6 7.6 4.9 6.6 0.6 8.4 4.9 17 5 18 305 2.6 0 2.9 2.5 10/01/2005 06:00:00 6.2 0.5 7.6 4.6 6.5 0.6 8 4.9 23 6 27 305 2.6 0 2.9 2.5 10/01/2005 06:10:00 5.4 0.7 7.6 4.2 5.7 0.7 8.4 4.2 18 6 11 305 2.6 0 2.9 2.5 10/01/2005 06:20:00 4.8 0.6 6.5 3.4 5.1 0.6 6.8 3.4 15 6 12 305 2.6 0 3.2 2.5 10/01/2005 06:30:00 4.5 0.5 5.7 3.4 4.8 0.5 6.1 3.8 19 5 22 305 2.6 0 2.9 2.5 10/01/2005 06:40:00 4.1 0.5 5.3 3 4.5 0.5 5.7 3.4 22 5 18 305 2.6 0 2.9 2.5 10/01/2005 06:50:00 4.4 0.3 4.9 3.4 4.8 0.3 5.7 4.2 17 5 9 305 2.5 0.1 2.9 2.2 10/01/2005 07:00:00 4.3 0.5 5.7 3.4 4.7 0.5 6.1 3.8 12 5 12 305 2.5 0 2.9 2.2 10/01/2005 07:10:00 4.9 0.6 6.1 3.4 5.3 0.6 6.5 3.8 4 6 10 305 2.3 0.1 2.7 2.2 10/01/2005 07:20:00 4.9 0.4 5.7 3.8 5.3 0.4 6.5 4.6 5 6 8 305 2.3 0.1 2.7 2.2 10/01/2005 07:30:00 4.8 0.6 6.1 3.4 5.2 0.6 6.5 3.8 4 5 0 305 2.3 0.1 2.7 2.2 10/01/2005 07:40:00 4.6 0.6 6.5 3.4 5 0.6 6.8 3.8 351 7 353 305 2.2 0.1 2.7 2 10/01/2005 07:50:00 4.5 0.5 5.7 3 4.9 0.5 6.1 3.4 351 5 341 305 2.2 0.1 2.5 2 10/01/2005 08:00:00 4.9 0.5 6.1 4.2 5.3 0.5 6.5 4.2 354 5 356 305 2.2 0.1 2.5 2 10/01/2005 08:10:00 4.9 0.7 6.8 3.4 5.3 0.7 6.8 3.8 5 6 11 305 2.2 0.1 2.5 2 10/01/2005 08:20:00 5.1 0.6 6.8 3.4 5.5 0.6 6.8 3.8 1 8 1 305 2.2 0.1 2.5 2 10/01/2005 08:30:00 3.8 0.5 4.9 2.6 4.2 0.6 5.3 3 356 5 5 305 2 0.1 2.5 1.7 10/01/2005 08:40:00 4.3 0.4 5.3 3.4 4.5 0.4 5.3 3.4 351 5 345 305 2 0.1 2.5 1.7 10/01/2005 08:50:00 4 0.5 5.3 3 4.5 0.5 6.1 3.4 351 5 357 305 2 0.1 2.5 2 10/01/2005 09:00:00 4.1 0.4 5.3 3 4.6 0.5 5.7 3.4 346 4 344 305 2 0.1 2.5 1.7 10/01/2005 09:10:00 3.7 0.4 4.6 2.6 4.1 0.5 5.3 3 349 4 346 305 2 0 2.5 2 10/01/2005 09:20:00 4.2 0.5 5.3 2.6 4.6 0.6 6.1 3 359 4 0 305 2.1 0 2.5 2 10/01/2005 09:30:00 4.8 0.7 6.5 3 5.2 0.7 6.8 3.8 9 7 0 305 2.2 0.1 2.5 2 10/01/2005 09:40:00 4.8 0.5 6.1 3.4 5.1 0.6 6.5 3.8 8 5 4 305 2.2 0.1 2.5 2 10/01/2005 09:50:00 5 0.4 6.1 4.2 5.4 0.5 6.5 4.6 11 7 1 305 2.2 0.1 2.5 2 10/01/2005 10:00:00 5.3 0.5 6.5 4.2 5.7 0.5 6.8 4.2 6 5 4 305 2.2 0.1 2.7 2 10/01/2005 10:10:00 5.1 0.7 6.8 3.8 5.6 0.7 7.2 4.2 9 5 10 305 2.3 0.1 2.7 2.2 10/01/2005 10:20:00 4.4 0.4 5.7 3.4 4.7 0.5 6.1 3.4 10 9 9 305 2.5 0 2.9 2.2 10/01/2005 10:30:00 4.2 0.6 5.7 3 4.5 0.7 6.1 3.4 10 5 2 305 2.5 0 2.7 2.2 10/01/2005 10:40:00 4.1 0.6 5.7 2.6 4.3 0.6 5.7 2.6 13 5 12 305 2.6 0.1 3.2 2.5 10/01/2005 10:50:00 3.6 0.4 5.3 2.3 3.9 0.4 5.3 2.6 1 8 16 305 2.6 0.1 3.2 2.5 10/01/2005 11:00:00 3.8 0.4 4.9 2.6 4 0.4 4.9 3 8 9 20 305 2.8 0.1 3.2 2.5 10/01/2005 11:10:00 3.7 0.4 4.9 2.6 3.9 0.4 4.9 3 17 6 18 305 2.6 0 3.2 2.5 10/01/2005 11:20:00 4.1 0.4 5.3 3.4 4.3 0.4 5.3 3.4 11 7 2 305 2.7 0.1 3.2 2.5 10/01/2005 11:30:00 4.1 0.5 6.1 2.6 4.3 0.5 6.1 3.4 16 8 7 305 2.7 0.1 3.2 2.5 10/01/2005 11:40:00 4 0.4 5.3 3 4.3 0.4 5.7 3 19 4 9 305 2.8 0.1 3.2 2.5 10/01/2005 11:50:00 4 0.7 6.1 2.6 4.2 0.7 6.1 3 12 6 16 305 2.9 0.2 3.4 2.7 10/01/2005 12:00:00 3.9 0.5 5.3 2.6 4.1 0.5 5.3 3 8 6 12 305 2.8 0.1 3.4 2.7 10/01/2005 12:10:00 3.4 0.4 4.9 2.6 3.6 0.4 4.9 2.6 8 7 4 305 2.9 0.2 3.4 2.7 10/01/2005 12:20:00 3.4 0.5 4.2 2.3 3.6 0.5 4.6 2.3 12 5 7 305 3.1 0.1 3.7 2.9 10/01/2005 12:30:00 3.1 0.5 4.6 1.9 3.4 0.4 4.6 2.6 12 9 19 305 3.3 0.1 3.7 2.9 10/01/2005 12:40:00 2.9 0.6 4.2 1.5 3.2 0.5 4.2 1.9 26 10 27 305 3.3 0 3.7 3.2 10/01/2005 12:50:00 3 0.6 4.6 1.9 3.3 0.6 4.6 2.3 16 8 5 305 3.3 0 3.7 3.2 10/01/2005 13:00:00 2.8 0.4 3.8 1.9 3.1 0.4 3.8 2.3 21 9 357 305 3.3 0 3.7 2.9 10/01/2005 13:10:00 3.2 0.5 4.2 2.3 3.4 0.5 4.6 2.3 20 8 21 305 3.6 0.1 3.9 3.2 10/01/2005 13:20:00 3.4 0.4 4.9 2.3 3.6 0.4 4.6 2.3 20 13 19 305 3.7 0 4.2 3.7 10/01/2005 13:30:00 3.6 0.5 4.9 2.3 3.8 0.5 4.9 2.6 2 8 7 305 3.7 0 3.9 3.4 10/01/2005 13:40:00 4.1 0.6 5.7 3 4.3 0.6 5.7 3 10 9 23 305 3.8 0 4.2 3.7 10/01/2005 13:50:00 4.3 0.4 5.3 3.4 4.4 0.4 5.3 3.4 11 6 7 305 3.6 0.1 4.2 3.2 10/01/2005 14:00:00 4.3 0.5 6.1 3 4.4 0.6 6.1 3 20 7 54 305 3.7 0 3.9 3.4 10/01/2005 14:10:00 3.8 0.4 4.9 3 4 0.4 5.3 3 20 7 16 305 3.7 0 4.2 3.4 10/01/2005 14:20:00 3.8 0.5 4.9 2.6 4 0.5 4.9 2.6 16 7 23 305 3.7 0.1 4.2 3.4 10/01/2005 14:30:00 3.5 0.6 4.9 1.9 3.6 0.6 4.9 2.3 22 8 19 305 4 0 4.4 3.7 10/01/2005 14:40:00 3.1 0.4 4.2 1.9 3.2 0.4 4.2 2.3 27 13 33 305 4.2 0 4.4 3.9 10/01/2005 14:50:00 3.8 0.7 5.3 2.3 3.9 0.6 5.3 2.6 21 12 24 305 3.8 0.1 4.2 3.4 10/01/2005 15:00:00 3.7 0.4 4.9 2.6 3.8 0.4 4.9 2.6 24 5 27 305 3.7 0 4.2 3.4 10/01/2005 15:10:00 3.1 0.5 4.2 1.9 3.2 0.5 4.6 2.3 17 8 7 305 3.6 0 3.7 3.4 10/01/2005 15:20:00 3.7 0.6 5.3 2.6 3.8 0.6 5.3 2.6 36 7 36 305 3.4 0 3.7 3.2 10/01/2005 15:30:00 2.7 0.5 3.8 1.5 2.8 0.4 3.8 1.9 23 9 32 305 3.3 0 3.4 3.2 10/01/2005 15:40:00 3.1 0.7 4.9 1.9 3.3 0.8 4.9 1.9 39 9 43 305 3.4 0 3.7 3.2 10/01/2005 15:50:00 3.1 0.5 4.2 2.3 3.2 0.5 4.6 2.3 37 9 41 305 3.3 0 3.7 3.2 10/01/2005 16:00:00 3.5 0.5 4.9 2.3 3.6 0.5 4.6 2.3 46 9 43 305 3.4 0.1 3.7 3.2 10/01/2005 16:10:00 3.6 0.5 4.9 2.3 3.7 0.5 4.9 2.6 49 8 41 305 3.3 0.1 3.7 3.2 10/01/2005 16:20:00 2.9 0.5 4.2 1.9 3 0.5 4.2 1.9 48 5 41 305 3.2 0 3.7 3.2 10/01/2005 16:30:00 3 0.4 3.8 1.9 3.2 0.4 4.2 2.3 42 8 33 305 3.2 0 3.4 2.9 10/01/2005 16:40:00 3.1 0.4 4.2 2.3 3.3 0.4 4.2 2.3 39 9 43 305 3.2 0 3.4 2.9 10/01/2005 16:50:00 3.7 0.4 4.6 2.6 3.8 0.4 4.6 3 28 12 40 305 3.2 0 3.4 2.9 10/01/2005 17:00:00 3.2 0.6 4.6 1.9 3.5 0.7 4.9 2.3 31 11 30 305 3.2 0 3.4 2.9 10/01/2005 17:10:00 2.9 0.6 4.2 1.5 3.1 0.5 4.6 1.9 44 10 31 305 3.1 0 3.4 2.9 10/01/2005 17:20:00 2.9 0.6 4.6 1.9 3 0.6 4.6 1.9 62 8 62 305 3.1 0 3.4 2.9 10/01/2005 17:30:00 3 0.6 4.6 2.3 3.1 0.6 4.9 1.9 37 11 33 305 3.1 0 3.4 2.9 10/01/2005 17:40:00 3.4 0.5 4.9 2.3 3.6 0.5 4.9 2.6 37 5 38 305 3 0 3.4 2.7 10/01/2005 17:50:00 2.9 0.5 3.8 1.9 3.1 0.4 4.2 2.3 53 10 48 305 3 0 3.4 2.9 10/01/2005 18:00:00 3.1 0.6 4.2 1.5 3.2 0.6 4.2 1.9 33 9 28 305 3.1 0.1 3.4 2.9 10/01/2005 18:10:00 3.1 0.5 4.2 1.9 3.2 0.5 4.2 2.3 29 5 21 305 3 0 3.4 2.9 10/01/2005 18:20:00 3.1 0.4 4.2 1.9 3.3 0.4 4.2 2.3 27 5 35 305 3.1 0.1 3.4 2.9 10/01/2005 18:30:00 3.3 0.4 4.2 2.3 3.5 0.5 4.2 2.3 45 8 32 305 3.3 0.1 3.7 2.9 10/01/2005 18:40:00 3.5 0.4 4.6 2.6 3.7 0.4 4.9 2.6 40 6 42 305 3.3 0.1 3.7 2.9 10/01/2005 18:50:00 3.1 0.5 4.6 1.9 3.4 0.5 4.6 2.3 35 10 42 305 2.8 0.1 3.2 2.7 10/01/2005 19:00:00 3 0.5 4.2 1.5 3.2 0.5 4.2 1.9 35 7 33 305 2.7 0 3.2 2.5 10/01/2005 19:10:00 3.5 0.3 4.2 2.6 3.7 0.4 4.6 3 25 5 27 305 2.7 0.1 3.2 2.5 10/01/2005 19:20:00 3.6 0.5 4.6 2.6 3.9 0.5 4.6 3 21 3 25 305 2.6 0 3.2 2.5 10/01/2005 19:30:00 3.1 0.5 3.8 2.3 3.3 0.5 4.2 2.6 33 6 30 305 2.6 0 3.2 2.5 10/01/2005 19:40:00 3.3 0.5 4.6 2.3 3.5 0.5 4.9 2.6 27 6 17 305 2.6 0.1 3.2 2.2 10/01/2005 19:50:00 3.3 0.6 4.9 1.9 3.5 0.6 4.9 2.3 32 7 25 305 2.5 0.1 2.9 2.2 10/01/2005 20:00:00 3.9 0.5 4.9 3 4.1 0.5 5.3 3 16 4 21 305 2.5 0 2.9 2.2 10/01/2005 20:10:00 3.7 0.3 4.6 3 3.9 0.3 4.6 3 26 6 39 305 2.5 0.1 2.9 2.2 10/01/2005 20:20:00 4.2 0.4 4.9 3 4.4 0.4 5.3 3.4 24 3 21 305 2.4 0.1 2.7 2.2 10/01/2005 20:30:00 4.5 0.6 5.7 3.4 4.7 0.6 6.5 3.8 25 5 16 305 2.4 0.1 2.7 2.2 10/01/2005 20:40:00 5 0.4 5.7 4.2 5.4 0.4 6.1 4.2 19 4 23 305 2.4 0.1 2.7 2.2 10/01/2005 20:50:00 5.1 0.4 6.1 4.2 5.4 0.4 6.5 4.6 14 3 18 305 2.3 0.1 2.7 2.2 10/01/2005 21:00:00 4.8 0.6 6.1 3.8 5.2 0.6 6.5 3.8 19 3 21 305 2.3 0.1 2.7 2.2 10/01/2005 21:10:00 4.3 0.3 4.9 3.4 4.6 0.3 5.3 3.8 22 5 28 305 2.2 0.1 2.7 2 10/01/2005 21:20:00 3.8 0.4 4.9 3 3.9 0.4 5.3 3 21 8 18 305 2.1 0 2.5 2 10/01/2005 21:30:00 3.6 0.4 4.6 2.6 3.8 0.4 4.6 2.6 27 5 26 305 2 0 2.5 2 10/01/2005 21:40:00 3.3 0.4 4.6 2.6 3.5 0.4 4.9 2.6 30 8 23 305 2.2 0.1 2.7 2 10/01/2005 21:50:00 3.2 0.5 4.9 2.3 3.5 0.5 4.9 2.3 24 6 17 305 2.2 0.1 2.7 2 10/01/2005 22:00:00 2.8 0.6 4.2 1.5 3.1 0.5 4.6 1.9 27 3 26 305 2.2 0.1 2.7 2 10/01/2005 22:10:00 1.4 0.3 1.9 0.7 1.8 0.3 2.3 0.7 39 9 37 305 2.2 0.2 2.7 1.5 10/01/2005 22:20:00 1.8 0.8 3 0.4 1.9 0.6 3.4 0.7 28 16 37 305 1.4 0.2 2.2 1 10/01/2005 22:30:00 2.1 0.5 3 1.1 2.4 0.5 3.4 1.5 22 7 10 305 1.6 0.5 2.7 0.8 10/01/2005 22:40:00 1.7 0.8 3 0.4 2.2 0.6 3.4 1.1 21 13 35 305 2.3 0.2 2.9 2 10/01/2005 22:50:00 1.1 0.7 2.6 0.4 1.5 0.6 3 0.4 16 12 2 305 1.4 0.4 2.5 0.8 10/01/2005 23:00:00 1.7 0.5 2.6 0.4 1.7 0.4 2.6 0.7 15 8 25 305 0.6 0.2 1.3 0.3 10/01/2005 23:10:00 2.2 0.4 3 1.5 2.6 0.4 3.4 1.9 8 4 5 305 1.2 0.5 2.5 0.6 10/01/2005 23:20:00 2.3 0.2 3 1.5 2.6 0.2 3.4 1.9 21 4 13 305 2.3 0 2.9 2.2 10/01/2005 23:30:00 2.4 0.3 3.4 1.5 2.7 0.3 3.4 1.9 27 6 31 305 2.5 0 2.9 2.2 10/01/2005 23:40:00 2.4 0.3 3 1.9 2.6 0.3 3.4 2.3 36 5 32 305 2.5 0 2.9 2.2 10/01/2005 23:50:00 2.7 0.4 3.8 1.9 2.9 0.4 4.2 2.3 39 4 36 305 2.5 0.1 2.9 2.2 10/02/2005 00:00:00 2.1 0.5 3.8 1.1 2.4 0.4 3.8 1.5 36 11 46 305 2.6 0 3.2 2.5 10/02/2005 00:10:00 1.9 0.8 3.4 0.4 2.2 0.7 3.8 1.1 35 10 25 305 2.7 0.2 3.2 2.5 10/02/2005 00:20:00 3.2 0.6 5.3 1.9 3.4 0.5 4.9 2.3 10 8 10 305 2.7 0.1 3.2 2.5 10/02/2005 00:30:00 2.8 0.6 4.6 1.5 3.1 0.6 4.9 2.3 8 6 5 305 2.8 0.2 3.2 2.5 10/02/2005 00:40:00 0.6 0.4 2.3 0.4 1.2 0.5 2.6 0.4 353 10 4 305 2.8 0.2 3.2 2.5 10/02/2005 00:50:00 0.8 0.4 1.5 0.4 1.1 0.5 1.9 0.4 329 12 334 305 2.7 0.1 3.2 2.2 10/02/2005 01:00:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 73 86 305 305 2.5 0.1 2.9 2.2 10/02/2005 01:10:00 0.7 0.5 2.6 0.4 1 0.5 2.3 0.4 121 33 69 305 2.6 0.1 3.2 2.5 10/02/2005 01:20:00 1.5 0.6 2.6 0.4 1.7 0.5 3 0.7 80 16 81 305 2.4 0.2 2.9 2.2 10/02/2005 01:30:00 1.4 0.5 2.6 0.4 1.8 0.5 2.6 0.7 29 17 42 305 2.6 0.2 3.2 2 10/02/2005 01:40:00 1.5 0.6 2.6 0.4 1.9 0.5 2.6 0.7 68 15 61 305 2.6 0.2 3.2 2.2 10/02/2005 01:50:00 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 43 21 305 305 2.6 0.2 3.2 2.2 10/02/2005 02:00:00 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 76 8 88 305 2.3 0.1 2.9 2.2 10/02/2005 02:10:00 1.1 0.6 2.3 0.4 1.6 0.4 2.3 0.7 101 10 102 305 2.2 0.2 2.5 2 10/02/2005 02:20:00 1.8 0.3 2.6 1.1 2.1 0.2 2.6 1.5 93 8 99 305 1.9 0.1 2.2 1.7 10/02/2005 02:30:00 2.2 0.4 3.8 1.5 2.4 0.3 3.8 1.9 94 5 93 305 2.2 0.1 2.5 2 10/02/2005 02:40:00 1.9 0.6 3 0.4 2.1 0.4 3 0.4 81 16 90 305 2.2 0.1 2.7 2 10/02/2005 02:50:00 1.7 0.8 3.8 0.4 2 0.6 3 1.1 57 15 67 305 2.3 0.2 2.9 2.2 10/02/2005 03:00:00 2.2 0.6 3.4 0.4 2.5 0.5 3.8 1.1 52 13 65 305 2.7 0.2 3.2 2.2 10/02/2005 03:10:00 0.6 0.5 2.3 0.4 1 0.6 2.3 0.4 48 15 41 305 2.8 0.2 3.2 2.5 10/02/2005 03:20:00 0.6 0.4 1.5 0.4 1.2 0.4 1.9 0.4 82 28 106 305 2.7 0.2 3.2 2.2 10/02/2005 03:30:00 2 0.9 4.2 0.4 2.2 0.7 4.2 1.1 89 20 78 305 2.3 0.1 2.9 2.2 10/02/2005 03:40:00 2 0.8 4.2 0.4 2.1 0.7 4.2 0.7 90 17 101 305 2.5 0.1 2.9 2.2 10/02/2005 03:50:00 2.1 0.7 3.4 0.4 2.3 0.5 3.8 0.7 90 11 87 305 2.5 0.2 2.9 2.2 10/02/2005 04:00:00 1.5 0.9 3.8 0.4 2.1 0.7 3.8 1.1 88 24 68 305 2.3 0.1 2.9 2.2 10/02/2005 04:10:00 2.7 0.5 3.8 1.1 2.9 0.4 3.8 1.5 108 13 100 305 2.3 0.1 2.7 2.2 10/02/2005 04:20:00 1.1 0.6 2.6 0.4 1.5 0.5 2.6 0.7 74 15 64 305 2.5 0.1 2.9 2.2 10/02/2005 04:30:00 0.7 0.5 1.9 0.4 1 0.5 2.3 0.4 52 13 43 305 2.5 0.1 2.9 2.2 10/02/2005 04:40:00 0.7 0.5 2.3 0.4 1.2 0.5 2.6 0.4 21 13 4 305 2.6 0 2.9 2.5 10/02/2005 04:50:00 0.7 0.5 2.6 0.4 1.1 0.7 2.6 0.4 336 64 348 305 2.7 0 3.2 2.5 10/02/2005 05:00:00 0.4 0 0.7 0.4 0.7 0.3 1.5 0.4 84 41 346 305 2.5 0.1 2.9 2.2 10/02/2005 05:10:00 1.5 0.4 2.6 0.7 2 0.4 2.6 0.4 332 7 327 305 2.5 0.1 3.2 2.2 10/02/2005 05:20:00 1.6 0.3 2.6 0.7 2 0.3 2.6 1.5 321 6 325 305 2.7 0 3.2 2.5 10/02/2005 05:30:00 2.1 0.6 3.4 0.4 2.5 0.6 3.8 1.1 10 30 34 305 2.7 0.1 3.2 2.5 10/02/2005 05:40:00 1.6 0.4 2.6 0.7 2.1 0.3 3 1.5 28 10 36 305 2.8 0.1 3.2 2.7 10/02/2005 05:50:00 1.5 0.6 3 0.4 2 0.5 3 1.1 19 8 12 305 2.8 0.1 3.2 2.7 10/02/2005 06:00:00 1.6 0.9 3 0.4 1.9 0.7 3.4 0.4 76 16 73 305 2.7 0.1 3.2 2.5 10/02/2005 06:10:00 2 0.9 3.8 0.4 2.4 0.7 4.2 0.7 51 12 32 305 2.6 0 3.2 2.5 10/02/2005 06:20:00 3 0.4 3.8 2.3 3.2 0.4 4.2 2.3 64 9 69 305 2.6 0 3.2 2.5 10/02/2005 06:30:00 3.3 0.8 4.9 1.5 3.3 0.7 4.9 1.9 60 20 70 305 2.6 0.1 3.2 2.5 10/02/2005 06:40:00 2.6 0.5 3.8 1.1 2.7 0.4 4.2 1.9 83 12 44 305 2.6 0.1 3.2 2.5 10/02/2005 06:50:00 3.3 0.9 5.7 1.1 3.4 0.9 5.3 1.5 57 15 64 305 2.6 0.1 3.2 2.5 10/02/2005 07:00:00 2.3 0.8 4.2 0.7 2.6 0.7 4.6 1.1 34 15 13 305 2.8 0.1 3.2 2.5 10/02/2005 07:10:00 2.9 0.5 4.2 1.5 3.2 0.5 4.2 1.9 42 29 41 305 2.8 0.1 3.2 2.7 10/02/2005 07:20:00 2.9 0.8 4.6 1.1 3.1 0.7 4.9 1.9 54 8 56 305 2.8 0.1 3.2 2.7 10/02/2005 07:30:00 2.5 0.5 3.8 1.1 2.6 0.5 3.8 1.5 60 12 62 305 2.7 0 3.2 2.5 10/02/2005 07:40:00 2.8 0.7 4.6 0.7 2.9 0.6 4.2 1.1 86 11 89 305 2.6 0 3.2 2.5 10/02/2005 07:50:00 3 0.8 4.9 0.7 3.1 0.7 4.9 1.9 83 10 76 305 2.7 0 3.2 2.5 10/02/2005 08:00:00 3.1 0.5 4.2 1.9 3.1 0.5 4.2 1.9 74 11 71 305 2.6 0 2.9 2.5 10/02/2005 08:10:00 2.9 1.3 5.7 0.4 3.1 1.1 5.3 0.7 94 15 106 305 2.5 0 2.9 2.2 10/02/2005 08:20:00 2.3 1 4.9 0.4 2.5 0.8 4.9 0.4 104 21 118 305 2.6 0 2.9 2.5 10/02/2005 08:30:00 2.7 0.9 4.2 0.4 2.9 0.7 4.2 1.1 98 18 112 305 2.6 0 2.9 2.5 10/02/2005 08:40:00 1.7 0.6 3 0.4 2 0.5 3.4 0.7 100 21 85 305 2.6 0 2.9 2.5 10/02/2005 08:50:00 1.9 0.6 3.8 0.7 2.2 0.5 3.8 1.5 90 19 82 305 2.6 0 2.9 2.5 10/02/2005 09:00:00 3.3 0.8 4.9 1.9 3.4 0.6 5.3 2.3 97 12 83 305 2.6 0 3.2 2.5 10/02/2005 09:10:00 3 0.6 4.2 0.7 3 0.6 4.2 1.5 91 14 72 305 2.6 0.1 3.2 2.5 10/02/2005 09:20:00 1.7 0.6 3.4 0.4 2.3 0.5 3.8 0.7 148 33 82 305 2.3 0.2 2.9 2 10/02/2005 09:30:00 1.8 0.5 3.4 0.4 2.6 0.4 3.4 1.5 175 15 137 305 2.1 0.1 2.5 2 10/02/2005 09:40:00 1.1 0.6 3 0.4 1.9 0.6 3.8 0.7 154 29 149 305 2.1 0.1 2.5 2 10/02/2005 09:50:00 2 1.3 5.3 0.4 2.1 1.1 5.7 0.4 102 22 92 305 2.2 0.2 2.7 2 10/02/2005 10:00:00 3.6 1.1 6.5 0.7 3.7 1 6.5 1.5 107 19 90 305 2.6 0 2.9 2.2 10/02/2005 10:10:00 3.8 1 8.4 1.5 3.9 1 8 1.9 80 15 51 305 2.7 0.1 3.2 2.5 10/02/2005 10:20:00 3.2 1.4 6.5 0.4 3.3 1.2 6.8 1.1 86 26 72 305 2.8 0.1 3.2 2.7 10/02/2005 10:30:00 4.6 0.8 7.2 2.6 4.5 0.8 6.8 3 77 10 75 305 2.8 0.1 3.2 2.7 10/02/2005 10:40:00 3.9 0.8 6.1 1.1 3.9 0.7 5.3 1.1 78 15 77 305 2.8 0.1 3.2 2.7 10/02/2005 10:50:00 4.4 1.1 7.6 1.5 4.5 1.1 7.2 1.9 72 20 85 305 2.7 0.1 3.2 2.5 10/02/2005 11:00:00 4.6 1.7 9.1 1.1 4.6 1.6 9.1 1.1 76 19 64 305 2.7 0 3.2 2.7 10/02/2005 11:10:00 3.8 1.1 6.8 0.7 3.9 1.1 6.5 1.1 78 20 82 305 2.8 0.2 3.2 2.7 10/02/2005 11:20:00 4.4 1.2 8.8 1.9 4.4 1.2 8.4 2.3 73 15 70 305 2.8 0.1 3.2 2.7 10/02/2005 11:30:00 3.7 1.7 9.1 0.4 3.8 1.5 8.8 1.1 88 24 72 305 2.8 0.2 3.2 2.7 10/02/2005 11:40:00 3.4 1.2 6.5 0.4 3.6 1 6.1 0.4 109 43 119 305 2.9 0.1 3.4 2.7 10/02/2005 11:50:00 3.9 1.2 7.2 0.4 4 1 6.5 1.9 73 28 111 305 2.9 0.1 3.2 2.7 10/02/2005 12:00:00 3.1 0.9 6.1 0.4 3.3 0.9 6.5 1.1 115 26 79 305 3.1 0.1 3.7 2.9 10/02/2005 12:10:00 3.9 1.2 6.5 0.4 4.1 1.1 6.5 1.1 135 19 141 305 3.4 0.1 3.7 3.2 10/02/2005 12:20:00 3.6 0.9 5.7 0.7 3.9 0.8 5.7 1.9 135 17 107 305 3.4 0.2 3.7 3.2 10/02/2005 12:30:00 4 1.6 6.8 1.1 4.2 1.3 6.8 1.5 120 29 89 305 3.5 0.2 3.9 3.2 10/02/2005 12:40:00 4.7 1.3 8.4 1.5 4.9 1.2 8 2.3 135 17 130 305 3.7 0.1 4.2 3.4 10/02/2005 12:50:00 4.4 1.1 6.8 1.9 4.4 1 6.8 1.9 134 16 126 305 4 0.1 4.4 3.7 10/02/2005 13:00:00 5.1 0.9 7.6 2.6 5.2 1 8 2.3 135 11 118 305 3.9 0.1 4.4 3.7 10/02/2005 13:10:00 4.5 1.1 7.6 1.1 4.5 1 7.6 2.6 127 16 128 305 3.9 0.1 4.7 3.7 10/02/2005 13:20:00 4.9 1.2 7.2 2.3 5 1.1 6.8 2.6 131 13 133 305 4.5 0.1 4.9 4.2 10/02/2005 13:30:00 5.6 0.8 7.6 3.4 5.7 0.8 7.6 3 131 12 106 305 4.5 0.1 4.9 4.4 10/02/2005 13:40:00 5.2 0.9 7.6 3 5.4 0.7 8 3.8 137 13 136 305 4.7 0.1 5.2 4.4 10/02/2005 13:50:00 5 0.9 7.6 2.6 5.1 0.8 7.6 2.6 137 12 120 305 4.4 0.1 4.9 4.2 10/02/2005 14:00:00 5 0.9 7.2 2.6 5.1 0.8 7.6 3 133 15 141 305 4.4 0.1 4.9 4.2 10/02/2005 14:10:00 4.8 1 7.2 2.3 5 1 8 2.3 139 13 156 305 4.8 0 5.2 4.7 10/02/2005 14:20:00 4.6 0.8 7.2 2.3 4.7 1 7.2 2.3 135 12 148 305 4.7 0 4.9 4.4 10/02/2005 14:30:00 4.9 1.2 8 2.3 4.9 1.2 8.4 2.3 141 12 147 305 4.7 0 4.9 4.4 10/02/2005 14:40:00 4.1 0.9 6.1 2.3 4.2 0.8 6.5 2.3 134 20 142 305 4.9 0 5.4 4.7 10/02/2005 14:50:00 3.6 1.3 6.8 0.4 3.6 1.2 7.2 0.7 99 38 102 305 4.7 0 4.9 4.4 10/02/2005 15:00:00 4.1 1 7.2 1.9 4 1 6.8 1.9 84 20 76 305 4.4 0.1 4.9 4.2 10/02/2005 15:10:00 4.3 1.3 8 1.1 4.3 1.1 7.2 1.9 71 19 84 305 4 0 4.4 3.9 10/02/2005 15:20:00 3.5 1.1 6.1 0.7 3.4 1 5.7 1.1 80 24 71 305 4.1 0 4.4 3.9 10/02/2005 15:30:00 2.9 1.1 4.9 0.4 3 1.1 5.7 0.4 110 23 79 305 4.2 0.1 4.7 4.2 10/02/2005 15:40:00 3.1 1 5.3 0.4 3.3 0.9 5.3 0.4 84 28 92 305 4.2 0.2 4.7 3.7 10/02/2005 15:50:00 2.6 1.2 5.7 0.4 2.7 1.1 5.3 0.7 71 22 46 305 3.9 0.1 4.4 3.7 10/02/2005 16:00:00 2.9 1.5 6.5 0.4 3 1.2 6.1 0.4 102 29 77 305 4.5 0.1 4.9 4.2 10/02/2005 16:10:00 3.5 0.7 5.3 1.5 4.4 0.9 6.5 1.9 175 13 186 305 4.4 0.3 4.9 3.7 10/02/2005 16:20:00 4.5 1 6.8 1.9 4.8 0.8 6.8 3 150 15 141 305 4 0 4.4 3.7 10/02/2005 16:30:00 5.2 0.9 7.2 3 5.3 0.8 7.2 3.8 141 10 149 305 4.1 0 4.4 3.9 10/02/2005 16:40:00 3.3 0.9 6.1 0.7 3.6 0.8 6.1 1.1 126 20 140 305 4.5 0.1 4.7 4.4 10/02/2005 16:50:00 4.1 0.9 6.1 1.5 4.5 0.7 6.8 3 153 17 127 305 4.5 0.1 4.9 4.4 10/02/2005 17:00:00 3.2 1 5.3 0.7 3.6 0.9 5.7 1.5 150 19 172 305 4.2 0 4.4 4.2 10/02/2005 17:10:00 4.2 1 7.2 1.5 4.3 0.9 6.8 1.9 133 18 126 305 4.1 0 4.4 3.9 10/02/2005 17:20:00 5 1 7.2 2.3 4.9 1 6.8 2.3 133 17 114 305 4.1 0 4.4 3.9 10/02/2005 17:30:00 4.8 1.4 7.6 1.9 4.8 1.4 8 1.9 129 18 149 305 4.2 0 4.7 4.2 10/02/2005 17:40:00 4.5 1.2 7.2 1.9 4.4 1.1 7.2 1.9 142 12 133 305 4.2 0 4.4 4.2 10/02/2005 17:50:00 4 1.3 7.2 0.4 4.1 1.2 7.2 1.1 127 21 154 305 4.1 0 4.4 3.9 10/02/2005 18:00:00 6 1.3 8.4 3 6 1.2 8.8 3 137 11 139 305 4.1 0 4.4 3.9 10/02/2005 18:10:00 5.7 1.1 9.1 3 5.8 1.1 8.8 3.4 137 11 148 305 4.2 0.1 4.7 3.9 10/02/2005 18:20:00 4.8 0.9 6.8 2.3 4.9 0.8 7.2 2.3 129 17 136 305 3.9 0.1 4.4 3.7 10/02/2005 18:30:00 5 1.7 8.8 1.9 5.1 1.5 8.8 2.3 143 13 134 305 3.9 0.1 4.4 3.7 10/02/2005 18:40:00 6.3 0.8 8.4 3.8 6.3 0.9 8.4 4.2 137 9 133 305 3.8 0 4.4 3.7 10/02/2005 18:50:00 6.2 1.3 8.8 2.6 6.2 1.1 8.8 3.4 140 11 144 305 3.6 0 3.7 3.2 10/02/2005 19:00:00 5.2 1 7.6 2.6 5.3 1 7.6 2.6 141 13 156 305 3.5 0 3.9 3.4 10/02/2005 19:10:00 5.7 1.2 9.5 3 5.9 1.1 9.5 3.4 145 15 144 305 3.6 0 3.9 3.4 10/02/2005 19:20:00 5.7 1.7 10.3 1.9 5.8 1.6 9.9 2.3 137 16 156 305 3.6 0 4.2 3.4 10/02/2005 19:30:00 6.3 1.1 10.3 4.2 6.2 1 9.9 3.8 134 13 142 305 3.7 0 4.2 3.4 10/02/2005 19:40:00 5.5 1.1 8.8 3.4 5.4 1 7.6 3 137 13 128 305 3.7 0 4.2 3.4 10/02/2005 19:50:00 6.5 1.2 8.8 3 6.4 1 8.8 3.8 139 9 136 305 3.7 0 4.2 3.4 10/02/2005 20:00:00 6.6 0.8 8.8 4.2 6.6 0.8 8.4 4.2 138 9 138 305 3.7 0 4.2 3.4 10/02/2005 20:10:00 6.1 1 8.8 3.8 6.2 0.9 8.4 4.2 137 10 141 305 3.7 0 4.2 3.4 10/02/2005 20:20:00 6.2 1 8.8 4.2 6.2 1 8.4 3.8 138 7 128 305 3.7 0 4.2 3.4 10/02/2005 20:30:00 6.2 0.8 8 4.2 6.1 0.8 8 3.8 135 8 140 305 3.6 0.1 4.2 3.4 10/02/2005 20:40:00 6.4 1 8.4 4.2 6.4 1 8.8 3.8 137 10 134 305 3.4 0.2 4.2 3.2 10/02/2005 20:50:00 7.1 1 9.9 4.6 7.1 1 9.5 4.6 139 8 141 305 3.7 0 4.2 3.4 10/02/2005 21:00:00 6.2 1 8.8 2.6 6.1 0.9 8.4 4.2 137 10 138 305 3.7 0 4.2 3.4 10/02/2005 21:10:00 6.2 0.8 8.4 4.2 6.2 0.7 8 4.2 135 8 140 305 3.9 0.1 4.4 3.7 10/02/2005 21:20:00 5.2 1 7.6 2.3 5.2 0.9 7.2 2.6 137 11 134 305 3.9 0.1 4.4 3.7 10/02/2005 21:30:00 4.8 1.4 7.6 1.9 4.9 1.3 7.6 2.3 132 14 132 305 4.1 0.2 4.7 3.9 10/02/2005 21:40:00 3.4 1.2 7.2 0.7 3.3 1 6.1 1.1 107 26 112 305 4 0.2 4.7 3.7 10/02/2005 21:50:00 4.2 1.3 6.8 1.1 4.2 1.1 7.2 1.1 123 21 129 305 4 0.2 4.4 3.7 10/02/2005 22:00:00 5.1 1.4 8.4 1.5 5.1 1.3 9.1 2.3 108 28 81 305 4 0.2 4.7 3.7 10/02/2005 22:10:00 5 1.3 9.1 2.6 4.9 1.2 9.1 2.6 128 19 96 305 4 0.2 4.4 3.7 10/02/2005 22:20:00 5.8 2 11.1 1.9 5.9 1.7 10.3 1.1 129 17 122 305 4 0.2 4.7 3.7 10/02/2005 22:30:00 7.4 1.3 10.7 4.2 7.5 1.2 10.7 4.6 142 13 139 305 4 0.2 4.7 3.7 10/02/2005 22:40:00 8 1.5 11.5 4.9 7.9 1.5 11.1 4.6 138 11 147 305 4 0.2 4.4 3.7 10/02/2005 22:50:00 8.8 1.3 12.2 6.1 8.8 1.3 12.2 5.7 136 9 133 305 3.9 0.1 4.4 3.7 10/02/2005 23:00:00 9.8 1.1 12.2 6.5 9.7 1.1 12.6 6.5 137 6 146 305 3.9 0.2 4.4 3.7 10/02/2005 23:10:00 8.9 1 11.5 5.7 8.7 1 10.7 6.5 136 8 135 305 3.9 0.1 4.4 3.7 10/02/2005 23:20:00 8.9 1.3 11.5 5.3 8.6 1.3 11.5 5.7 136 8 138 305 3.9 0.2 4.4 3.7 10/02/2005 23:30:00 9.2 1.1 11.5 6.5 9.1 1.1 11.5 6.5 136 6 143 305 3.7 0.1 4.4 3.4 10/02/2005 23:40:00 9.1 1.3 11.8 4.9 8.8 1.4 11.5 5.3 137 8 138 305 3.6 0.1 4.2 3.2 10/02/2005 23:50:00 9.3 1.2 11.8 6.5 9.1 1.2 11.8 6.1 136 7 132 305 3.4 0.1 3.9 3.2 10/03/2005 00:00:00 10.2 1.1 12.6 7.2 10 1.1 13 6.8 137 6 138 305 3.4 0.1 3.9 3.2 10/03/2005 00:10:00 10.6 1 12.2 6.1 10.3 1 12.2 6.5 134 6 136 305 3.6 0.1 4.2 3.2 10/03/2005 00:20:00 10.7 0.8 12.6 8.4 10.5 0.9 13.7 8 134 5 130 305 3.6 0.1 4.2 3.4 10/03/2005 00:30:00 9.6 1.1 12.6 6.1 9.3 1.1 12.6 6.5 135 8 132 305 3.5 0.2 3.9 3.2 10/03/2005 00:40:00 8.6 1.2 11.5 5.7 8.4 1.2 11.8 5.3 137 9 130 305 3.5 0.2 3.9 3.4 10/03/2005 00:50:00 8.6 1.3 12.2 4.9 8.3 1.2 11.8 4.9 136 9 142 305 3.5 0.2 3.9 3.4 10/03/2005 01:00:00 8.7 1.1 11.5 6.1 8.5 1 11.5 6.1 137 8 138 305 3.6 0.1 4.2 3.4 10/03/2005 01:10:00 8.9 1.2 12.2 5.7 8.7 1.1 12.6 5.3 138 10 131 305 3.6 0.1 4.2 3.4 10/03/2005 01:20:00 7.8 1.4 11.5 4.6 7.6 1.3 10.7 4.6 137 11 119 305 3.6 0.2 4.2 3.4 10/03/2005 01:30:00 8 1.3 11.1 3.8 8 1.1 10.7 4.9 136 9 133 305 3.6 0.1 4.2 3.4 10/03/2005 01:40:00 8.2 1.4 12.2 4.9 8 1.3 12.2 4.9 135 10 141 305 3.6 0.2 4.2 3.2 10/03/2005 01:50:00 7.8 1.3 11.1 4.2 7.7 1.3 10.7 4.6 138 10 141 305 3.6 0 4.2 3.4 10/03/2005 02:00:00 6.1 1.3 9.1 2.6 6.1 1.3 9.9 2.6 138 13 145 305 3.7 0 4.2 3.4 10/03/2005 02:10:00 5.6 1.5 10.3 2.3 5.6 1.3 9.9 2.3 134 16 131 305 3.7 0 4.2 3.4 10/03/2005 02:20:00 4.9 1.4 9.1 1.1 4.8 1.3 9.5 1.5 127 21 117 305 3.8 0 4.2 3.4 10/03/2005 02:30:00 5.5 1.7 9.5 1.9 5.5 1.5 8.8 2.6 130 15 130 305 3.8 0.1 4.4 3.7 10/03/2005 02:40:00 5.9 1.3 9.1 2.3 5.8 1.3 9.1 2.6 134 15 133 305 3.9 0.1 4.4 3.7 10/03/2005 02:50:00 6.4 1.3 9.9 2.6 6.4 1.3 9.5 3.4 137 13 145 305 3.9 0.1 4.4 3.7 10/03/2005 03:00:00 6.5 1.3 9.5 2.3 6.6 1.3 9.1 3.4 137 13 129 305 3.9 0.2 4.4 3.7 10/03/2005 03:10:00 6.2 1.2 9.5 3 6.2 1.2 8.8 3 132 12 138 305 3.9 0.1 4.4 3.7 10/03/2005 03:20:00 6.3 1 9.1 3.8 6.3 1 9.1 3.4 132 14 112 305 3.9 0.1 4.4 3.7 10/03/2005 03:30:00 5.7 1.1 9.1 3.4 5.8 1.1 9.9 3.4 137 13 141 305 3.9 0.1 4.4 3.7 10/03/2005 03:40:00 6.1 1.2 8.8 3 6 1.2 8.4 2.6 136 12 141 305 3.9 0.2 4.4 3.7 10/03/2005 03:50:00 7.7 1.3 10.7 4.9 7.5 1.3 10.7 4.2 137 10 143 305 3.9 0.1 4.4 3.7 10/03/2005 04:00:00 7.8 1.1 9.9 4.6 7.7 1.1 10.3 4.9 136 8 140 305 3.6 0.2 4.2 3.2 10/03/2005 04:10:00 6.2 1.2 9.1 4.2 6.2 1.1 9.1 3.8 133 15 140 305 3.4 0.2 3.7 3.2 10/03/2005 04:20:00 6.4 1.4 10.3 3 6.2 1.5 9.9 3.4 135 12 142 305 3.4 0.1 3.7 3.2 10/03/2005 04:30:00 7 1.1 9.5 4.2 7 1 9.1 3.8 137 11 143 305 3.6 0 4.2 3.4 10/03/2005 04:40:00 6.2 1.1 9.1 3 6.1 1.1 9.1 3.8 133 13 135 305 3.5 0.1 3.9 3.4 10/03/2005 04:50:00 7 1.7 10.3 3 7 1.5 10.3 3 134 13 138 305 3.6 0 4.2 3.4 10/03/2005 05:00:00 6.6 1.2 9.5 3.8 6.5 1.2 10.3 3.8 131 15 151 305 3.5 0.1 3.9 3.2 10/03/2005 05:10:00 5.6 1.2 8.4 3 5.7 1.1 8.4 2.6 131 15 116 305 3.3 0.1 3.7 3.2 10/03/2005 05:20:00 6 1.5 10.3 2.3 6 1.3 9.9 3.4 125 15 121 305 3.4 0.1 3.7 3.2 10/03/2005 05:30:00 6.4 1.4 9.5 3 6.2 1.3 9.5 3 129 13 136 305 3.4 0.1 3.7 3.2 10/03/2005 05:40:00 7.3 1.1 10.7 4.6 7.2 1.1 10.7 4.6 137 9 150 305 3.4 0.1 3.7 3.2 10/03/2005 05:50:00 6.9 0.9 8.8 4.2 6.7 1 9.1 3.4 134 9 126 305 3.4 0.1 3.7 3.2 10/03/2005 06:00:00 7.4 1 9.5 3.4 7.3 1 9.1 4.2 136 6 147 305 3.4 0.1 3.7 3.2 10/03/2005 06:10:00 6 1.1 8.4 3 5.9 1 8.4 3.4 144 10 138 305 3.3 0.1 3.7 3.2 10/03/2005 06:20:00 5.9 1 7.6 3 5.9 0.8 7.6 3.8 137 9 145 305 3.4 0.1 3.7 3.2 10/03/2005 06:30:00 6.7 1.2 10.3 3.4 6.5 1.2 10.7 3.8 140 13 141 305 3.5 0.1 3.9 3.2 10/03/2005 06:40:00 6.5 1.1 9.1 4.2 6.5 1 9.1 4.2 139 11 148 305 3.4 0.2 3.9 3.2 10/03/2005 06:50:00 6.3 1.1 9.1 3 6.2 1 8.8 4.2 138 10 139 305 3.4 0.1 3.7 3.2 10/03/2005 07:00:00 5.6 1 7.6 2.6 5.5 1 7.6 3 141 13 140 305 3.4 0.1 3.7 3.4 10/03/2005 07:10:00 6.4 1 9.5 4.2 6.2 1 8.8 3.8 137 9 147 305 3.4 0.1 3.7 3.2 10/03/2005 07:20:00 8.3 1 10.7 5.7 8.2 0.9 10.3 5.7 138 6 142 305 3.4 0.1 3.7 3.2 10/03/2005 07:30:00 6.1 1.2 9.1 3 6 1.1 9.1 3.8 146 12 143 305 3.4 0.1 3.7 3.2 10/03/2005 07:40:00 5.9 1 8 3.4 6 1.1 8.8 2.6 134 13 135 305 3.3 0.1 3.7 3.2 10/03/2005 07:50:00 5.4 1 8 3 5.4 1 7.6 3.4 136 12 146 305 3.3 0.1 3.7 3.2 10/03/2005 08:00:00 6.3 1.1 8.4 2.6 6.2 1.1 8.8 3.4 140 12 124 305 3.4 0.1 3.9 3.2 10/03/2005 08:10:00 6.9 0.9 9.9 4.6 6.9 0.9 10.3 4.6 134 8 137 305 3.7 0 4.2 3.4 10/03/2005 08:20:00 6.6 1.1 9.5 3.8 6.4 1 9.1 3.8 136 9 136 305 3.8 0 4.2 3.7 10/03/2005 08:30:00 6.6 1 9.5 4.2 6.5 1 9.1 4.2 136 11 147 305 3.9 0.1 4.4 3.7 10/03/2005 08:40:00 6.3 1.2 9.5 3 6.2 1.3 9.9 3 131 14 124 305 3.9 0.1 4.4 3.7 10/03/2005 08:50:00 6.7 1 9.1 4.2 6.5 1 9.1 4.2 133 13 113 305 3.9 0.1 4.4 3.7 10/03/2005 09:00:00 6.8 1.1 9.5 4.2 6.7 1.1 9.1 4.6 131 12 130 305 3.9 0 4.2 3.7 10/03/2005 09:10:00 7.2 1.1 10.3 3.8 7.2 1.1 10.3 4.6 135 11 136 305 3.9 0.1 4.4 3.7 10/03/2005 09:20:00 6.8 1.2 9.5 3.8 6.8 1.1 9.9 3.8 136 9 145 305 3.9 0.1 4.4 3.7 10/03/2005 09:30:00 7.5 1.1 9.9 4.9 7.5 0.9 9.5 4.9 135 9 146 305 3.9 0.1 4.4 3.7 10/03/2005 09:40:00 7.5 1.3 11.5 4.2 7.5 1.2 11.5 4.2 136 11 135 305 4 0.1 4.4 3.7 10/03/2005 09:50:00 7.7 0.9 9.9 4.9 7.6 1.1 10.7 4.9 135 11 144 305 4 0.2 4.4 3.7 10/03/2005 10:00:00 7.5 1.5 13 4.2 7.4 1.5 11.8 3.8 136 11 139 305 4 0.1 4.4 3.7 10/03/2005 10:10:00 7.9 1.5 11.5 4.6 7.8 1.3 11.1 4.6 135 10 145 305 4 0.2 4.4 3.7 10/03/2005 10:20:00 7.8 1.3 13.3 4.9 7.8 1.2 11.8 4.6 136 9 136 305 4 0.2 4.4 3.7 10/03/2005 10:30:00 8.2 1.1 11.5 5.7 8.1 1.1 11.5 5.3 135 8 138 305 4 0.2 4.4 3.7 10/03/2005 10:40:00 7.5 1.3 10.7 3.8 7.4 1.2 9.9 4.6 135 10 136 305 4.1 0.1 4.7 3.9 10/03/2005 10:50:00 6.5 1.1 8.8 3.4 6.6 1 8.8 4.2 139 10 133 305 4.2 0.1 4.7 3.9 10/03/2005 11:00:00 6.4 1 8.8 3 6.4 0.9 8.4 3.8 137 10 140 305 4.4 0.1 4.7 4.2 10/03/2005 11:10:00 6.1 0.9 8.4 4.2 6.2 1 9.5 3.8 136 9 127 305 4.4 0.1 4.7 4.2 10/03/2005 11:20:00 5.7 1.2 9.1 3 5.8 1.1 9.1 3.4 139 12 133 305 4.3 0 4.7 4.2 10/03/2005 11:30:00 6.4 1 9.1 3.8 6.5 0.9 8.8 4.2 140 12 143 305 4.4 0 4.7 4.2 10/03/2005 11:40:00 5.7 1.2 9.5 3.4 5.6 1.2 9.1 3.4 125 15 127 305 4.4 0 4.7 4.4 10/03/2005 11:50:00 6.2 1.2 9.1 2.3 6.1 1 9.1 3.4 132 13 133 305 4.4 0 4.7 4.4 10/03/2005 12:00:00 6 1 9.1 3.4 6.1 1.1 9.5 3.4 135 13 144 305 4.6 0 4.9 4.4 10/03/2005 12:10:00 6.2 1.1 9.1 3 6.3 1.1 9.5 3.8 138 11 149 305 4.7 0 4.9 4.7 10/03/2005 12:20:00 6.8 1.1 9.5 3.8 6.8 1.1 9.9 4.2 139 11 143 305 4.8 0 4.9 4.7 10/03/2005 12:30:00 7.6 1 9.9 4.9 7.6 0.9 11.1 5.3 137 8 136 305 4.8 0 5.2 4.7 10/03/2005 12:40:00 7.3 1 9.5 4.6 7.4 0.9 9.5 4.6 134 10 135 305 5 0 5.4 4.9 10/03/2005 12:50:00 7.9 1 10.3 5.3 7.9 0.9 10.3 5.3 137 8 140 305 5.2 0 5.4 4.9 10/03/2005 13:00:00 7.7 1.1 10.3 4.9 7.7 1.1 11.5 4.9 135 9 138 305 5.3 0 5.4 4.9 10/03/2005 13:10:00 7.7 1 9.9 5.3 7.6 1 9.5 5.3 141 9 142 305 5.4 0 5.6 5.4 10/03/2005 13:20:00 8 1.1 10.3 4.9 8 1.1 11.5 4.9 140 10 143 305 5.5 0 5.9 5.4 10/03/2005 13:30:00 7.8 1.2 11.8 4.2 7.9 1.2 11.8 4.6 142 9 141 305 5.6 0 5.9 5.4 10/03/2005 13:40:00 7.9 1 10.7 5.3 7.9 1.1 10.7 5.3 138 11 135 305 5.6 0 5.9 5.4 10/03/2005 13:50:00 6.9 1.2 10.7 3.8 6.8 1.2 9.5 4.2 135 13 118 305 5.8 0.1 5.9 5.6 10/03/2005 14:00:00 6.2 1.3 9.9 3.4 6.1 1.3 10.3 3.4 130 15 131 305 6 0 6.1 5.6 10/03/2005 14:10:00 5.9 1.1 8.8 3 5.8 1.1 8.4 3.4 128 15 108 305 6.3 0 6.4 5.9 10/03/2005 14:20:00 6 1.3 8.8 3.4 6 1.2 9.1 3.4 132 15 140 305 6.3 0 6.4 6.1 10/03/2005 14:30:00 5.4 1.1 8.4 3 5.2 1.1 8.4 2.3 121 22 120 305 6.4 0 6.7 6.1 10/03/2005 14:40:00 5.6 1.2 7.6 2.6 5.5 1.2 8 2.3 125 15 124 305 6.5 0 6.9 6.1 10/03/2005 14:50:00 6.1 1 8.4 4.2 6.1 1.1 9.1 4.2 128 13 138 305 6.3 0 6.4 6.1 10/03/2005 15:00:00 5.4 1 8 2.3 5.3 0.9 8 3 114 19 108 305 6.5 0 6.7 6.1 10/03/2005 15:10:00 5.8 0.9 8.4 2.6 5.7 1 8 3.4 123 17 130 305 6.6 0 6.9 6.4 10/03/2005 15:20:00 5 1.1 7.6 1.5 4.9 1.2 7.6 1.9 124 19 152 305 6.7 0 6.9 6.4 10/03/2005 15:30:00 4.3 1 7.2 1.5 4.3 1 7.6 1.9 126 21 138 305 7 0 7.2 6.9 10/03/2005 15:40:00 3.4 1.1 5.7 0.4 3.5 1.1 6.1 0.4 132 24 154 305 7.1 0 7.4 7.2 10/03/2005 15:50:00 4.8 1.5 8.4 1.5 4.5 1.3 7.6 1.9 115 23 119 305 7.2 0.1 7.7 6.9 10/03/2005 16:00:00 4 1.5 7.6 0.4 4 1.2 7.2 1.9 130 23 138 305 7.1 0.1 7.7 6.9 10/03/2005 16:10:00 3 1.3 6.8 0.4 3.1 1.3 7.2 0.4 80 45 145 305 7 0 7.7 6.7 10/03/2005 16:20:00 2.7 1.5 6.5 0.4 2.8 1.5 6.5 0.4 69 33 72 305 6.9 0.1 7.7 6.4 10/03/2005 16:30:00 3.3 1 5.7 1.1 3.1 1 5.3 1.1 95 38 80 305 6.8 0.1 7.2 6.4 10/03/2005 16:40:00 3.1 1.3 7.6 0.4 3 1.2 7.2 1.1 93 43 112 305 7.1 0 7.4 7.2 10/03/2005 16:50:00 2.8 1.1 6.5 0.4 2.7 1.1 5.3 0.4 67 35 102 305 6.8 0.1 7.2 6.4 10/03/2005 17:00:00 2.4 1.1 5.3 0.4 2.5 1 4.9 0.4 69 39 53 305 6.8 0.1 7.2 6.7 10/03/2005 17:10:00 2.4 1 4.9 0.4 2.3 0.8 4.6 0.4 74 33 56 305 7 0 7.2 6.9 10/03/2005 17:20:00 3.1 1.7 7.6 0.4 3.2 1.6 8 0.4 60 39 49 305 6.7 0.2 7.2 6.4 10/03/2005 17:30:00 4 1.3 7.6 1.1 4.2 1.3 8 1.5 43 18 61 305 6.5 0 6.7 6.4 10/03/2005 17:40:00 5.1 1.3 8.4 2.3 5.1 1.3 8.8 1.5 55 16 56 305 6.1 0 6.4 5.9 10/03/2005 17:50:00 4.2 2.3 10.3 0.4 4.2 2.2 9.9 0.4 76 33 59 305 6.3 0.1 6.7 6.1 10/03/2005 18:00:00 5.8 1.5 9.5 2.3 5.7 1.6 9.9 2.3 75 24 118 305 6 0 6.1 5.9 10/03/2005 18:10:00 5.9 1.6 10.3 3 5.6 1.6 9.9 3 87 22 53 305 6.1 0 6.4 5.9 10/03/2005 18:20:00 7.2 1.6 13 3.4 7.1 1.5 12.2 3.4 70 15 65 305 5.9 0 6.1 5.6 10/03/2005 18:30:00 7 1.9 12.2 1.9 6.7 1.9 11.8 3 70 18 53 305 5.8 0 5.9 5.6 10/03/2005 18:40:00 7.5 1.5 12.6 4.2 7.5 1.4 12.6 3.8 67 13 68 305 5.7 0 5.9 5.6 10/03/2005 18:50:00 7.5 1.7 12.6 3 7.3 1.7 11.5 3 75 20 59 305 5.6 0 5.9 5.6 10/03/2005 19:00:00 8.2 1.1 11.5 4.9 8 1.3 11.8 4.6 74 12 86 305 5.5 0 5.6 5.4 10/03/2005 19:10:00 8 1.3 11.5 4.6 7.9 1.3 12.2 4.9 81 12 65 305 5.5 0 5.6 5.4 10/03/2005 19:20:00 7.7 1.5 12.2 3.4 7.6 1.5 11.8 4.6 82 13 67 305 5.4 0 5.6 5.4 10/03/2005 19:30:00 7.4 1.4 11.1 4.2 7.4 1.4 11.5 4.2 80 12 82 305 5.2 0 5.4 5.2 10/03/2005 19:40:00 7.6 1.6 11.5 3.4 7.5 1.5 10.7 3.8 78 15 82 305 5.1 0 5.2 4.9 10/03/2005 19:50:00 7 1.4 12.2 4.2 7.2 1.5 12.2 4.2 69 15 42 305 5 0 5.2 4.9 10/03/2005 20:00:00 6.5 1.6 11.8 3.4 6.7 1.7 11.5 3 74 17 73 305 5 0 5.2 4.9 10/03/2005 20:10:00 6.7 1.5 11.5 2.6 6.9 1.6 11.1 2.6 67 14 63 305 5 0 5.2 4.9 10/03/2005 20:20:00 7.7 1.2 11.5 4.2 7.7 1.2 11.5 4.9 76 12 59 305 5 0 5.2 4.9 10/03/2005 20:30:00 7.3 1.2 9.9 4.2 7.3 1.2 10.7 4.2 77 11 70 305 4.9 0 5.2 4.9 10/03/2005 20:40:00 7 1.2 10.3 3.8 7 1.3 10.7 3.8 77 12 63 305 5 0 5.2 4.9 10/03/2005 20:50:00 6.8 1.3 11.1 4.6 6.9 1.2 10.3 4.2 76 15 92 305 5 0 5.2 4.9 10/03/2005 21:00:00 6.8 1 9.9 3.8 6.7 1.1 9.5 3.8 77 12 74 305 5.1 0 5.4 4.9 10/03/2005 21:10:00 6.8 1.5 10.7 3.4 6.6 1.6 12.2 3 76 16 84 305 5.2 0 5.4 4.9 10/03/2005 21:20:00 7.8 1 10.7 4.6 7.6 1 10.7 5.3 77 9 72 305 5.2 0 5.4 5.2 10/03/2005 21:30:00 8.3 0.7 9.9 6.1 8 0.7 9.1 5.7 77 6 71 305 5.2 0 5.4 5.2 10/03/2005 21:40:00 8.6 0.9 11.1 6.5 8.4 1 10.3 5.7 77 5 82 305 5.2 0 5.4 5.2 10/03/2005 21:50:00 8.5 0.8 10.7 6.1 8.3 0.8 10.3 5.7 80 6 82 305 5.2 0 5.4 5.2 10/03/2005 22:00:00 9.1 1 11.5 5.7 8.9 1 11.8 5.3 82 6 85 305 5.3 0 5.4 5.2 10/03/2005 22:10:00 8 0.9 11.5 5.3 7.8 0.9 9.9 5.3 84 8 84 305 5.3 0 5.4 5.2 10/03/2005 22:20:00 8.1 1.1 11.1 5.7 8 1.1 10.3 5.7 78 6 79 305 5.4 0 5.4 5.4 10/03/2005 22:30:00 8.4 0.8 10.3 6.1 8.4 0.8 10.7 5.7 79 6 78 305 5.3 0 5.4 5.4 10/03/2005 22:40:00 8.4 1 11.8 6.1 8.2 1 11.1 5.7 79 6 66 305 5.3 0 5.4 5.4 10/03/2005 22:50:00 7.9 0.7 9.9 6.1 7.7 0.8 9.9 5.7 77 8 72 305 5.3 0 5.4 5.2 10/03/2005 23:00:00 8.3 1 11.1 5.3 8 0.9 10.3 5.7 84 7 90 305 5.2 0 5.4 5.2 10/03/2005 23:10:00 8.5 0.7 9.9 6.5 8.3 0.7 9.9 6.5 85 6 78 305 5.2 0 5.4 4.9 10/03/2005 23:20:00 7.9 0.7 9.5 6.1 7.9 0.7 9.9 5.3 80 6 69 305 5 0 5.2 4.9 10/03/2005 23:30:00 8.7 1 11.5 5.3 8.7 1 11.5 5.7 79 8 84 305 4.9 0 5.2 4.9 10/03/2005 23:40:00 8.5 0.9 11.5 6.1 8.2 0.9 11.1 5.7 79 8 101 305 4.8 0 4.9 4.9 10/03/2005 23:50:00 9.6 0.8 11.8 7.2 9.5 0.9 11.8 6.8 78 5 72 305 4.9 0 5.2 4.9 10/04/2005 00:00:00 9.2 1.2 12.6 4.2 9.1 1.1 12.2 4.2 82 10 84 305 4.9 0 5.6 4.9 10/04/2005 00:10:00 8.8 1.4 13 5.3 8.8 1.3 12.6 5.7 78 14 84 305 4.8 0 4.9 4.9 10/04/2005 00:20:00 9.4 1.3 12.6 6.5 9.5 1.3 13.3 5.7 75 10 68 305 4.8 0 4.9 4.7 10/04/2005 00:30:00 9.5 1.5 14.5 5.3 9.7 1.4 13.7 5.3 76 10 108 305 4.8 0 4.9 4.9 10/04/2005 00:40:00 9.4 1.5 13 5.3 9.3 1.3 13 4.6 78 10 70 305 4.8 0 4.9 4.9 10/04/2005 00:50:00 9.5 0.8 11.5 6.1 9.3 0.9 11.8 6.8 80 6 80 305 4.8 0 4.9 4.9 10/04/2005 01:00:00 9.7 0.8 12.2 7.2 9.4 0.8 11.5 7.2 80 6 85 305 4.8 0 4.9 4.9 10/04/2005 01:10:00 9.7 0.7 11.5 7.6 9.5 0.7 11.5 7.2 75 6 77 305 4.8 0 4.9 4.7 10/04/2005 01:20:00 9.4 0.8 11.8 7.6 9.2 0.9 11.8 7.2 78 6 71 305 4.8 0 4.9 4.7 10/04/2005 01:30:00 10 0.8 11.8 7.2 9.8 0.8 11.8 7.6 72 5 77 305 4.7 0 4.9 4.7 10/04/2005 01:40:00 10.2 0.8 12.2 8 10.1 0.8 12.2 7.6 71 5 66 305 4.7 0 4.9 4.7 10/04/2005 01:50:00 9.9 0.6 11.5 8 9.9 0.7 11.8 8 71 4 80 305 4.7 0 4.9 4.7 10/04/2005 02:00:00 9.6 0.5 11.1 8 9.6 0.6 11.1 8 70 3 66 305 4.7 0 4.9 4.4 10/04/2005 02:10:00 9.7 0.7 11.5 7.6 9.7 0.7 11.8 7.6 71 4 73 305 4.7 0 4.9 4.7 10/04/2005 02:20:00 9.8 0.7 11.8 8 9.7 0.7 11.8 7.6 71 4 76 305 4.7 0 4.9 4.7 10/04/2005 02:30:00 9.8 0.7 12.2 8 9.7 0.8 11.5 7.6 70 5 59 305 4.8 0 4.9 4.7 10/04/2005 02:40:00 9.7 0.8 12.2 7.6 9.6 0.8 12.6 7.6 70 5 79 305 4.8 0 4.9 4.7 10/04/2005 02:50:00 9.8 0.9 12.2 7.6 9.6 1 12.2 6.8 73 6 71 305 4.8 0 4.9 4.7 10/04/2005 03:00:00 9.6 0.9 11.8 7.6 9.5 0.9 12.2 7.6 70 5 67 305 4.8 0 4.9 4.7 10/04/2005 03:10:00 9.4 1 12.2 7.2 9.3 1 12.2 6.8 71 6 65 305 4.8 0 4.9 4.7 10/04/2005 03:20:00 9.7 1 12.6 7.6 9.6 1 12.2 7.2 71 5 66 305 4.8 0 4.9 4.7 10/04/2005 03:30:00 9.5 0.8 12.2 7.6 9.4 0.8 12.2 7.2 71 5 65 305 4.8 0 4.9 4.7 10/04/2005 03:40:00 9.3 0.7 11.8 7.6 9.2 0.8 11.8 6.8 72 6 69 305 4.8 0 4.9 4.7 10/04/2005 03:50:00 8.9 1 11.5 6.5 8.8 1 11.5 6.5 71 7 65 305 4.8 0 4.9 4.7 10/04/2005 04:00:00 8.9 0.8 12.6 7.2 8.8 1 11.8 6.1 73 6 75 305 4.8 0 4.9 4.7 10/04/2005 04:10:00 9.3 0.7 11.5 7.6 9.3 0.8 11.5 7.2 69 6 64 305 4.8 0 4.9 4.7 10/04/2005 04:20:00 9 0.8 10.7 6.8 9 0.8 11.1 6.5 72 5 68 305 4.8 0 4.9 4.7 10/04/2005 04:30:00 9.3 1 11.8 6.8 9.2 1 11.5 6.5 69 5 71 305 4.8 0 4.9 4.7 10/04/2005 04:40:00 9.2 1 11.1 6.1 9.1 1 11.5 5.7 70 5 70 305 4.8 0 5.2 4.7 10/04/2005 04:50:00 9.2 0.9 11.1 6.8 9.1 0.9 11.5 6.5 69 5 70 305 4.9 0 5.2 4.9 10/04/2005 05:00:00 8.8 0.8 10.7 7.2 8.7 0.8 10.7 6.8 69 6 63 305 4.8 0 5.2 4.9 10/04/2005 05:10:00 9.1 0.8 10.7 6.8 9 0.9 10.7 6.5 73 5 68 305 5 0 5.4 4.9 10/04/2005 05:20:00 9.6 0.8 12.6 7.6 9.4 0.8 11.5 7.2 71 5 78 305 5 0 5.4 4.9 10/04/2005 05:30:00 8.5 0.8 10.3 6.1 8.4 0.9 10.7 5.7 71 6 65 305 5 0 5.4 4.9 10/04/2005 05:40:00 8.3 0.8 11.1 6.5 8.2 0.9 10.7 5.3 70 7 65 305 5.1 0 5.4 4.9 10/04/2005 05:50:00 8.7 0.8 11.5 6.8 8.6 0.9 11.8 6.5 64 4 67 305 5 0.1 5.4 4.9 10/04/2005 06:00:00 8.2 0.7 10.3 6.1 8 0.8 9.9 6.1 68 6 75 305 5.1 0 5.4 4.9 10/04/2005 06:10:00 8.7 0.6 10.3 6.8 8.6 0.6 9.9 6.8 62 5 56 305 5 0 5.4 4.9 10/04/2005 06:20:00 8.9 0.6 10.7 7.6 8.8 0.6 10.3 7.2 68 4 66 305 5.1 0 5.4 4.9 10/04/2005 06:30:00 8.3 0.7 10.7 6.5 8.2 0.7 10.7 6.5 68 4 73 305 5.2 0 5.4 4.9 10/04/2005 06:40:00 8.2 0.8 10.3 6.5 8.1 0.8 10.3 6.1 69 4 72 305 5.2 0 5.4 4.9 10/04/2005 06:50:00 8.7 0.8 11.1 6.5 8.6 0.8 11.5 6.5 72 5 74 305 5.1 0 5.4 4.9 10/04/2005 07:00:00 9.2 0.5 10.7 7.6 9.2 0.6 10.7 7.2 70 4 68 305 5.2 0 5.4 4.9 10/04/2005 07:10:00 8.9 0.6 11.1 6.8 8.9 0.7 10.7 7.2 67 3 66 305 5.2 0 5.4 4.9 10/04/2005 07:20:00 10.2 0.8 12.2 8.4 10.1 0.8 12.2 8 67 3 67 305 5.2 0 5.6 5.2 10/04/2005 07:30:00 9.8 1 12.2 6.8 9.7 1.1 12.2 7.2 73 7 67 305 5.3 0 5.6 5.2 10/04/2005 07:40:00 9.4 0.8 11.8 6.8 9.1 1 12.2 5.7 79 8 78 305 5.4 0 5.6 5.4 10/04/2005 07:50:00 8.6 1.2 11.8 6.1 8.4 1.2 11.8 5.3 78 5 67 305 5.4 0 5.6 5.4 10/04/2005 08:00:00 8.7 0.8 11.1 6.5 8.6 0.8 11.1 6.1 71 6 67 305 5.4 0 5.6 5.4 10/04/2005 08:10:00 9.6 0.9 12.2 7.2 9.4 0.9 11.8 6.8 75 6 64 305 5.4 0 5.6 5.4 10/04/2005 08:20:00 9.7 0.8 11.8 7.6 9.6 0.9 12.2 7.2 73 5 64 305 5.4 0 5.6 5.4 10/04/2005 08:30:00 9.7 0.8 11.8 7.6 9.6 0.8 12.2 8 74 5 71 305 5.4 0 5.6 5.4 10/04/2005 08:40:00 9.5 1 12.2 7.2 9.3 1.1 12.6 6.8 74 6 72 305 5.4 0 5.6 5.4 10/04/2005 08:50:00 9.6 1 11.5 6.5 9.2 1.1 11.5 6.1 82 5 78 305 5.4 0 5.6 5.2 10/04/2005 09:00:00 9.8 0.9 12.2 6.8 9.5 1 12.2 6.8 82 7 82 305 5.3 0 5.6 5.2 10/04/2005 09:10:00 9.4 0.9 11.5 6.8 9.2 1 11.5 6.5 79 5 78 305 5.4 0 5.6 5.4 10/04/2005 09:20:00 9.3 1 12.2 7.2 9.2 1 11.8 7.2 74 6 68 305 5.4 0 5.6 5.4 10/04/2005 09:30:00 10.1 0.8 11.8 7.6 10 0.8 11.8 7.2 73 5 70 305 5.4 0 5.6 5.4 10/04/2005 09:40:00 9.3 0.7 10.7 7.6 9.2 0.8 11.1 6.8 73 5 73 305 5.4 0 5.6 5.4 10/04/2005 09:50:00 9.1 0.7 10.7 7.2 9 0.7 11.1 6.8 71 6 71 305 5.4 0 5.6 5.4 10/04/2005 10:00:00 9.6 1 12.2 6.8 9.4 1.2 11.8 6.8 76 7 69 305 5.4 0 5.6 5.4 10/04/2005 10:10:00 9.6 0.8 11.8 6.8 9.5 0.9 11.8 6.8 77 6 71 305 5.4 0 5.6 5.4 10/04/2005 10:20:00 9.8 0.8 12.6 7.6 9.7 0.9 12.6 7.2 75 5 73 305 5.4 0 5.6 5.4 10/04/2005 10:30:00 10.6 0.8 12.6 8.4 10.4 0.9 13 8 71 4 69 305 5.4 0 5.6 5.2 10/04/2005 10:40:00 10.8 0.6 12.2 9.1 10.7 0.7 12.2 8.4 72 3 67 305 5.2 0 5.6 4.9 10/04/2005 10:50:00 10.4 0.7 12.2 8.4 10.3 0.7 12.2 8.4 73 4 84 305 5.2 0 5.4 4.9 10/04/2005 11:00:00 10.9 0.5 12.6 9.5 10.7 0.5 11.8 9.1 68 3 72 305 5.2 0 5.4 4.9 10/04/2005 11:10:00 10.4 0.6 11.8 8 10.3 0.8 11.8 7.6 69 4 69 305 5.3 0 5.6 4.9 10/04/2005 11:20:00 10 0.6 11.1 8 9.9 0.7 11.5 8 67 4 66 305 5.5 0 5.6 5.2 10/04/2005 11:30:00 10 0.5 11.5 8.8 10 0.6 11.5 7.6 66 3 71 305 5.5 0 5.6 5.4 10/04/2005 11:40:00 9.4 0.8 11.1 7.6 9.4 0.8 11.1 7.2 65 3 66 305 5.6 0 5.9 5.4 10/04/2005 11:50:00 9.9 0.7 11.1 7.6 9.8 0.8 11.5 7.2 67 3 65 305 5.7 0 5.9 5.6 10/04/2005 12:00:00 9.4 0.5 10.7 8 9.3 0.5 10.7 7.6 68 4 73 305 5.8 0 5.9 5.6 10/04/2005 12:10:00 9.3 0.5 10.3 7.6 9.2 0.6 10.3 7.6 68 4 71 305 5.8 0 5.9 5.6 10/04/2005 12:20:00 8.9 0.7 10.7 7.2 8.8 0.7 10.3 6.5 72 5 65 305 5.8 0 5.9 5.6 10/04/2005 12:30:00 8.2 0.6 9.5 6.1 8 0.7 9.5 5.3 75 5 78 305 6.1 0.1 6.4 5.9 10/04/2005 12:40:00 8.9 0.6 9.9 6.8 8.8 0.7 9.9 6.5 70 4 71 305 6 0 6.1 5.9 10/04/2005 12:50:00 8.4 0.6 9.5 6.8 8.2 0.6 9.5 6.5 69 4 68 305 5.9 0 6.1 5.6 10/04/2005 13:00:00 8.6 0.5 9.5 7.2 8.4 0.6 9.5 6.8 69 3 77 305 5.8 0 5.9 5.6 10/04/2005 13:10:00 8.7 0.5 9.9 7.2 8.5 0.5 9.5 6.5 68 3 72 305 6 0 6.1 5.9 10/04/2005 13:20:00 8.1 0.5 9.1 6.5 7.9 0.6 9.1 6.1 68 4 63 305 6.2 0 6.4 5.9 10/04/2005 13:30:00 7.6 0.5 8.8 6.1 7.4 0.6 8.8 5.7 66 5 61 305 6.5 0 6.9 6.1 10/04/2005 13:40:00 7.9 0.6 9.5 6.8 7.7 0.7 9.5 6.1 62 4 64 305 6.5 0 6.9 6.4 10/04/2005 13:50:00 8.3 0.4 9.5 6.8 8 0.5 9.5 6.1 59 4 57 305 6.5 0 6.9 6.4 10/04/2005 14:00:00 8.8 0.6 10.3 6.8 8.7 0.7 10.7 6.8 53 4 59 305 6.6 0 6.9 6.4 10/04/2005 14:10:00 8.6 0.5 9.9 7.2 8.4 0.7 10.3 6.5 51 3 48 305 6.7 0 7.2 6.4 10/04/2005 14:20:00 9.2 0.4 10.3 8 9.1 0.5 10.3 7.6 49 3 49 305 6.7 0 6.9 6.4 10/04/2005 14:30:00 8.6 0.6 9.9 6.8 8.5 0.7 9.9 6.8 47 4 40 305 6.7 0 6.9 6.4 10/04/2005 14:40:00 9.1 0.4 9.9 8.4 9.2 0.4 9.9 8 43 3 48 305 6.7 0 6.9 6.7 10/04/2005 14:50:00 9.9 0.5 11.1 8.4 9.9 0.6 11.5 8.8 43 4 49 305 6.6 0 6.9 6.4 10/04/2005 15:00:00 9.8 0.6 11.1 8.4 9.8 0.6 11.1 8 40 4 39 305 6.5 0 6.7 6.4 10/04/2005 15:10:00 10.3 0.6 11.5 8.8 10.3 0.6 11.8 8.8 37 3 35 305 6.5 0 6.9 6.4 10/04/2005 15:20:00 10.6 0.6 11.8 8.8 10.6 0.6 12.2 8.8 33 5 30 305 6.3 0 6.7 6.1 10/04/2005 15:30:00 9.9 0.6 11.1 8 9.9 0.6 11.8 8 34 4 37 305 6.3 0 6.7 6.1 10/04/2005 15:40:00 9.6 0.8 11.5 7.6 9.5 0.8 11.5 7.6 36 4 32 305 6.3 0 6.4 6.1 10/04/2005 15:50:00 10.4 0.5 11.8 8.8 10.4 0.6 11.8 8.8 38 5 35 305 6.1 0 6.4 5.9 10/04/2005 16:00:00 10.9 0.7 13 9.5 10.9 0.7 12.6 8.8 39 4 36 305 6.3 0 6.4 6.1 10/04/2005 16:10:00 11.1 0.5 12.6 9.5 11 0.6 12.2 9.5 42 5 43 305 6.4 0 6.4 6.1 10/04/2005 16:20:00 11.1 0.6 12.2 9.1 11 0.7 12.6 8.4 41 6 40 305 6.4 0 6.9 6.1 10/04/2005 16:30:00 10.9 0.5 12.2 9.1 10.8 0.5 12.2 9.1 36 4 40 305 6.3 0 6.4 6.1 10/04/2005 16:40:00 10.4 0.6 11.8 8.4 10.3 0.7 11.8 8 34 4 31 305 6 0 6.1 5.9 10/04/2005 16:50:00 10.9 0.6 12.2 9.5 10.8 0.7 12.2 9.5 33 4 34 305 6 0 6.1 5.9 10/04/2005 17:00:00 10.7 0.6 12.2 9.1 10.8 0.8 12.2 8.4 29 5 32 305 5.8 0 5.9 5.6 10/04/2005 17:10:00 11.2 0.6 12.6 9.5 11.2 0.7 13 9.5 28 4 37 305 5.8 0 5.9 5.6 10/04/2005 17:20:00 11.1 0.7 13 9.1 11.2 0.8 13 8.4 28 3 31 305 5.6 0 5.9 5.4 10/04/2005 17:30:00 10.9 0.7 12.6 9.1 11 0.8 12.6 8.8 26 3 28 305 5.5 0 5.6 5.4 10/04/2005 17:40:00 10.7 0.7 12.6 8.8 10.7 0.9 12.6 8.4 28 4 20 305 5.5 0 5.6 5.4 10/04/2005 17:50:00 11.3 0.7 13 8.4 11.4 0.8 13.3 8.8 24 4 25 305 5.3 0 5.4 5.2 10/04/2005 18:00:00 11.2 0.5 12.6 9.9 11.2 0.6 13 9.1 24 4 19 305 5.1 0 5.4 4.9 10/04/2005 18:10:00 11 0.6 12.2 9.1 10.9 0.7 12.2 9.1 31 4 35 305 5.3 0 5.6 5.2 10/04/2005 18:20:00 10.3 0.7 11.8 8.4 10.3 0.7 12.2 8.4 28 5 25 305 5 0 5.4 4.9 10/04/2005 18:30:00 10.7 1 12.6 8.4 10.9 1.1 13 8.4 24 6 24 305 4.9 0 5.2 4.7 10/04/2005 18:40:00 10.9 0.6 12.6 9.5 11 0.7 12.6 8.8 21 3 22 305 4.8 0 4.9 4.7 10/04/2005 18:50:00 10.4 0.6 11.8 8.8 10.5 0.6 12.2 8.8 23 3 26 305 4.8 0 4.9 4.7 10/04/2005 19:00:00 10.1 0.6 11.5 8 10.2 0.6 11.5 8.4 29 3 35 305 4.8 0 4.9 4.7 10/04/2005 19:10:00 9.7 0.5 10.7 8 9.8 0.5 11.1 8 25 4 29 305 4.7 0 4.9 4.7 10/04/2005 19:20:00 9.2 0.8 11.1 7.2 9.4 0.7 11.5 7.6 22 4 23 305 4.8 0 4.9 4.7 10/04/2005 19:30:00 9.5 0.7 11.1 7.2 9.6 0.7 11.5 7.2 32 3 30 305 4.8 0 4.9 4.7 10/04/2005 19:40:00 9.5 0.6 10.7 8 9.5 0.6 10.7 7.6 30 5 27 305 4.8 0 5.2 4.7 10/04/2005 19:50:00 10 0.7 11.5 8 10 0.7 11.5 8.4 36 5 39 305 4.8 0 5.2 4.7 10/04/2005 20:00:00 9.3 0.8 11.1 7.2 9.3 0.7 11.5 7.6 37 4 34 305 4.9 0 5.2 4.7 10/04/2005 20:10:00 10 0.6 11.5 8.4 9.9 0.7 11.5 7.2 36 3 38 305 4.9 0 5.4 4.9 10/04/2005 20:20:00 9.9 1 11.8 7.6 9.8 1 11.8 7.2 41 4 37 305 4.9 0 5.4 4.9 10/04/2005 20:30:00 10.6 0.7 11.8 8.4 10.5 0.7 11.8 8.4 42 4 39 305 5 0.1 5.4 4.9 10/04/2005 20:40:00 10.9 0.7 12.6 8.4 10.6 0.7 12.6 8.4 43 4 39 305 5 0.1 5.4 4.9 10/04/2005 20:50:00 10.5 0.8 12.2 8.4 10.5 0.7 12.2 8.4 41 5 35 305 5.2 0.1 5.4 4.9 10/04/2005 21:00:00 11 0.6 12.6 9.5 10.8 0.7 12.6 8.8 44 3 44 305 5.2 0 5.4 4.9 10/04/2005 21:10:00 10 0.6 11.5 8 9.9 0.7 11.5 8 40 4 46 305 5.2 0 5.6 4.9 10/04/2005 21:20:00 10.3 0.7 12.2 8 10.2 0.8 12.2 8.4 45 4 46 305 5.3 0 5.6 5.2 10/04/2005 21:30:00 9.7 0.6 11.5 8.4 9.7 0.6 11.1 8 38 4 45 305 5.3 0 5.6 5.2 10/04/2005 21:40:00 9.4 0.7 11.5 7.6 9.3 0.8 11.5 8 40 4 37 305 5.3 0 5.6 5.2 10/04/2005 21:50:00 9.6 0.6 10.7 8 9.5 0.6 10.7 8 38 3 33 305 5.3 0 5.6 5.2 10/04/2005 22:00:00 9.1 0.6 10.7 7.6 8.9 0.7 10.7 7.6 41 3 41 305 5.3 0 5.6 4.9 10/04/2005 22:10:00 9.1 0.6 10.3 7.6 8.9 0.7 10.7 7.2 39 3 35 305 5.3 0 5.6 5.2 10/04/2005 22:20:00 9.1 0.6 10.3 7.6 9 0.6 10.7 7.2 38 3 36 305 5.3 0 5.6 5.2 10/04/2005 22:30:00 8.7 0.5 9.9 7.2 8.6 0.5 9.9 7.2 37 3 41 305 5.3 0 5.6 5.2 10/04/2005 22:40:00 8.3 0.5 9.5 7.2 8.2 0.6 9.5 6.5 38 4 42 305 5.3 0 5.6 5.2 10/04/2005 22:50:00 8.7 0.7 9.9 6.8 8.7 0.7 9.9 6.8 32 3 29 305 5.4 0 5.9 5.4 10/04/2005 23:00:00 8.6 0.6 9.9 7.2 8.6 0.6 9.9 7.2 34 3 34 305 5.4 0 5.9 5.4 10/04/2005 23:10:00 8.8 0.6 9.9 7.6 8.8 0.5 10.3 7.6 35 3 33 305 5.5 0 5.9 5.4 10/04/2005 23:20:00 8.6 0.6 9.9 7.2 8.7 0.6 9.9 7.2 35 3 37 305 5.5 0.1 5.9 5.4 10/04/2005 23:30:00 8.8 0.6 10.3 7.2 8.8 0.6 10.3 7.2 35 3 34 305 5.5 0.1 5.9 5.4 10/04/2005 23:40:00 9.1 0.5 10.3 7.2 9.2 0.5 10.3 7.6 33 3 36 305 5.6 0.1 5.9 5.4 10/04/2005 23:50:00 8.9 0.6 10.3 7.2 8.9 0.6 10.3 7.6 27 3 25 305 5.5 0.1 5.9 5.4 10/05/2005 00:00:00 9.1 0.6 10.3 7.6 9.1 0.5 10.3 7.6 28 3 26 305 5.5 0.1 5.9 5.4 10/05/2005 00:10:00 9.8 0.6 11.1 7.6 9.8 0.6 11.5 8 27 3 28 305 5.5 0.1 5.9 5.4 10/05/2005 00:20:00 10.1 0.6 11.1 8.8 10.2 0.7 11.8 8.4 25 3 26 305 5.5 0.1 5.9 5.4 10/05/2005 00:30:00 10.2 0.5 11.5 8.8 10.3 0.7 12.2 8.8 25 3 23 305 5.5 0 5.9 5.4 10/05/2005 00:40:00 10.3 0.5 11.5 8.4 10.4 0.6 11.5 8.8 25 3 23 305 5.5 0 5.9 5.4 10/05/2005 00:50:00 10.1 0.6 11.1 8.4 10 0.7 11.5 8 29 3 27 305 5.5 0.1 5.9 5.4 10/05/2005 01:00:00 9.9 0.6 11.1 8.4 9.9 0.7 11.8 8 29 3 25 305 5.6 0.1 5.9 5.4 10/05/2005 01:10:00 9.8 0.5 11.1 8 9.8 0.5 11.5 8.4 29 3 32 305 5.6 0.1 5.9 5.4 10/05/2005 01:20:00 10 0.7 11.1 7.6 10 0.8 11.5 7.6 29 3 30 305 5.6 0.1 5.9 5.4 10/05/2005 01:30:00 10.4 0.5 11.8 9.1 10.4 0.6 12.2 8.8 29 3 27 305 5.6 0.1 5.9 5.4 10/05/2005 01:40:00 10.3 0.7 11.8 8.8 10.2 0.7 11.8 8.4 29 3 28 305 5.6 0.1 5.9 5.4 10/05/2005 01:50:00 10.9 0.5 12.2 9.5 10.9 0.6 12.2 9.1 27 3 26 305 5.6 0.1 5.9 5.4 10/05/2005 02:00:00 10.3 0.6 11.8 8 10.3 0.7 11.8 8 27 3 26 305 5.5 0.1 5.9 5.4 10/05/2005 02:10:00 9.2 0.6 10.7 7.6 9.2 0.7 11.5 7.2 28 3 30 305 5.5 0 5.9 5.4 10/05/2005 02:20:00 9.7 0.6 11.1 8 9.8 0.7 11.5 7.6 25 3 25 305 5.5 0 5.9 5.4 10/05/2005 02:30:00 9.1 0.6 10.3 7.6 9.1 0.6 10.7 7.6 27 4 27 305 5.4 0 5.9 5.4 10/05/2005 02:40:00 9.6 0.5 11.1 7.2 9.6 0.6 11.1 8 27 3 24 305 5.5 0 5.9 5.4 10/05/2005 02:50:00 9.3 0.5 10.7 8 9.4 0.6 10.7 7.6 26 3 23 305 5.5 0 5.9 5.4 10/05/2005 03:00:00 9.8 0.6 11.1 7.6 10 0.7 11.5 8 27 3 27 305 5.4 0 5.9 5.2 10/05/2005 03:10:00 9.7 0.5 10.7 8.4 9.8 0.6 11.1 7.6 27 3 27 305 5.3 0 5.6 5.2 10/05/2005 03:20:00 9.8 0.5 11.1 8.4 10 0.6 11.5 8.4 27 3 27 305 5.3 0 5.6 5.2 10/05/2005 03:30:00 9.6 0.5 11.1 8 9.7 0.7 11.5 7.6 27 3 24 305 5.2 0.1 5.6 4.9 10/05/2005 03:40:00 9.2 0.6 10.7 6.8 9.3 0.7 10.7 6.8 27 3 22 305 5.2 0.1 5.6 4.9 10/05/2005 03:50:00 9.2 0.4 10.3 8 9.4 0.5 10.7 8 24 3 22 305 5.2 0.1 5.6 4.9 10/05/2005 04:00:00 9.3 0.5 10.3 8 9.5 0.5 10.7 8 25 3 22 305 5.2 0.1 5.6 4.9 10/05/2005 04:10:00 8.7 0.5 10.3 7.2 8.8 0.6 10.3 7.2 30 4 31 305 5.3 0.1 5.6 4.9 10/05/2005 04:20:00 8.4 0.5 9.9 7.2 8.4 0.6 9.9 6.8 31 4 33 305 5.3 0 5.6 5.2 10/05/2005 04:30:00 9.2 0.6 10.3 6.8 9.1 0.6 10.7 7.2 43 6 40 305 5.4 0 5.9 5.2 10/05/2005 04:40:00 9.3 0.5 10.7 8 9.3 0.6 10.7 7.6 46 4 45 305 5.4 0 5.6 5.2 10/05/2005 04:50:00 9.4 0.5 10.7 8.4 9.4 0.5 10.7 8 35 5 31 305 5.4 0 5.9 5.2 10/05/2005 05:00:00 9.5 0.6 10.7 8 9.6 0.7 11.1 8 27 3 29 305 5.2 0.1 5.6 4.9 10/05/2005 05:10:00 9.3 0.6 10.3 7.2 9.3 0.6 10.7 7.6 31 4 28 305 5.1 0.1 5.6 4.9 10/05/2005 05:20:00 9.1 0.6 11.1 7.6 9.1 0.6 10.7 8 28 4 31 305 5.2 0.1 5.6 4.9 10/05/2005 05:30:00 10.1 0.7 12.2 8.4 10.1 0.8 12.2 8 25 4 23 305 5.2 0.1 5.4 4.9 10/05/2005 05:40:00 10.7 0.6 12.2 9.1 10.7 0.8 12.2 8.4 27 4 27 305 5.1 0.1 5.4 4.9 10/05/2005 05:50:00 10.9 0.6 12.6 9.5 10.8 0.6 12.6 9.5 30 4 32 305 5.2 0.1 5.6 4.9 10/05/2005 06:00:00 10.7 0.7 12.2 8.8 10.6 0.8 12.6 8.8 32 3 34 305 5.2 0 5.6 4.9 10/05/2005 06:10:00 11.4 0.9 13.3 9.1 11.2 1 13.3 8.8 32 4 29 305 5.2 0 5.6 4.9 10/05/2005 06:20:00 12.2 0.7 13.3 9.9 12.1 0.7 13.3 9.5 33 4 33 305 5.2 0 5.6 4.9 10/05/2005 06:30:00 11.9 0.8 14.1 9.9 11.8 0.9 14.1 9.1 35 5 32 305 5.2 0 5.6 4.9 10/05/2005 06:40:00 11.8 0.8 14.1 9.5 11.6 0.8 13.7 8.8 38 4 36 305 5.2 0.1 5.6 4.9 10/05/2005 06:50:00 11.8 0.9 13.7 9.1 11.7 0.9 13.7 8.8 35 5 35 305 5.2 0 5.6 4.9 10/05/2005 07:00:00 12.2 1 14.5 9.5 12.1 1.1 14.9 8.8 35 5 32 305 5.2 0 5.6 5.2 10/05/2005 07:10:00 11.8 1 13.7 9.5 11.5 1 13.7 8.8 41 4 40 305 5.2 0.1 5.6 5.2 10/05/2005 07:20:00 11.9 0.9 14.1 9.1 11.7 1 13.3 8.8 41 4 44 305 5.3 0 5.6 5.2 10/05/2005 07:30:00 12.3 0.7 14.1 10.3 12.1 0.8 14.5 9.9 38 5 38 305 5.3 0 5.6 5.2 10/05/2005 07:40:00 12.2 0.7 13.7 10.3 12 0.8 13.7 9.9 37 4 31 305 5.4 0 5.6 5.2 10/05/2005 07:50:00 11.7 1 14.1 9.1 11.5 1 13.7 8.8 37 5 32 305 5.3 0 5.6 5.2 10/05/2005 08:00:00 12.4 0.7 14.1 10.7 12.2 0.8 13.7 9.9 37 4 38 305 5.3 0 5.6 5.2 10/05/2005 08:10:00 11.7 0.9 14.1 9.5 11.6 0.9 14.5 9.1 38 4 40 305 5.3 0 5.6 5.2 10/05/2005 08:20:00 12.8 1 15.3 10.3 12.6 1.1 14.9 9.5 38 4 31 305 5.3 0 5.6 5.2 10/05/2005 08:30:00 12.6 0.8 14.5 10.3 12.5 1 14.9 9.9 36 5 43 305 5.3 0 5.6 5.2 10/05/2005 08:40:00 13.6 0.8 15.6 11.1 13.4 0.9 15.6 11.5 31 4 31 305 5.3 0 5.6 5.2 10/05/2005 08:50:00 13 1 15.3 10.7 12.8 1.1 15.3 9.9 33 4 29 305 5.3 0 5.6 5.2 10/05/2005 09:00:00 12.5 1.3 14.9 9.5 12.2 1.3 15.3 8.8 36 5 36 305 5.2 0 5.6 4.9 10/05/2005 09:10:00 12.2 0.9 14.5 9.5 12 1 14.5 9.1 36 5 32 305 5.3 0 5.6 5.2 10/05/2005 09:20:00 12.7 0.8 14.5 10.7 12.6 0.8 14.5 9.9 38 3 37 305 5.3 0 5.6 5.2 10/05/2005 09:30:00 11.6 1 14.5 9.1 11.5 1.1 14.1 8.8 32 6 28 305 5.3 0 5.6 5.2 10/05/2005 09:40:00 12.6 0.8 14.5 10.3 12.4 1 14.5 9.9 32 4 34 305 5.2 0 5.6 5.2 10/05/2005 09:50:00 12.7 0.9 14.5 10.3 12.5 1 14.5 10.3 33 4 38 305 5.2 0 5.6 4.9 10/05/2005 10:00:00 12.7 1 14.9 9.1 12.6 1.1 14.5 9.5 33 4 28 305 5.2 0 5.6 5.2 10/05/2005 10:10:00 12.7 0.8 14.9 10.7 12.5 0.8 15.3 10.3 39 3 40 305 5.3 0 5.6 5.2 10/05/2005 10:20:00 12.2 1 14.1 9.5 12.1 1 14.5 9.1 38 4 31 305 5.3 0 5.6 5.2 10/05/2005 10:30:00 11.5 0.8 13.7 8.8 11.4 0.8 13.7 8.4 31 5 32 305 5.4 0 5.6 5.2 10/05/2005 10:40:00 11.8 1 14.1 9.5 11.8 1 14.5 9.5 32 4 27 305 5.3 0 5.6 5.2 10/05/2005 10:50:00 11.2 0.8 13 8.8 11.2 0.9 13.3 9.1 27 4 26 305 5.4 0 5.6 5.2 10/05/2005 11:00:00 11.1 0.9 13.3 8.8 11 1 13.3 8.8 28 5 27 305 5.4 0 5.6 5.2 10/05/2005 11:10:00 11.1 0.8 13 8.8 11.2 0.8 13.3 9.1 24 4 26 305 5.3 0 5.6 5.2 10/05/2005 11:20:00 10.9 0.8 13 8.8 10.8 0.8 13 8.8 30 4 27 305 5.3 0 5.6 5.2 10/05/2005 11:30:00 11.5 1 13.7 8.8 11.4 1 13.7 8.4 33 4 25 305 5.3 0 5.6 5.2 10/05/2005 11:40:00 10.7 1 13 8.4 10.7 1 13.3 8.4 26 5 27 305 5.4 0 5.9 5.2 10/05/2005 11:50:00 11.7 0.8 13.7 9.9 11.8 1 14.1 9.1 26 4 29 305 5.2 0 5.6 5.2 10/05/2005 12:00:00 11.6 0.7 13.3 9.1 11.6 0.7 13.3 9.9 30 4 35 305 5.2 0 5.6 4.9 10/05/2005 12:10:00 11.4 0.7 13 9.5 11.3 0.8 13.3 8.8 29 4 27 305 5.2 0 5.6 5.2 10/05/2005 12:20:00 11.3 0.8 13.3 9.1 11.4 0.8 13.3 9.1 30 4 27 305 5.3 0 5.6 5.2 10/05/2005 12:30:00 11.2 0.8 13.3 8.8 11.3 0.9 13.7 9.1 28 4 24 305 5.3 0 5.6 5.2 10/05/2005 12:40:00 11.6 0.8 13.3 9.5 11.5 0.9 13.3 9.1 25 5 28 305 5.3 0 5.6 5.2 10/05/2005 12:50:00 11.7 0.8 13.7 9.5 11.8 0.9 14.1 9.1 25 4 25 305 5.2 0 5.6 5.2 10/05/2005 13:00:00 11.7 0.7 13.7 9.5 11.7 0.9 14.1 9.5 24 4 24 305 5.2 0 5.6 4.9 10/05/2005 13:10:00 11.2 0.8 13.3 8.8 11.2 0.8 13.3 8.8 24 4 23 305 5.2 0 5.6 4.9 10/05/2005 13:20:00 11.8 0.7 13.3 9.9 11.8 0.8 13.7 9.1 25 4 24 305 5.3 0 5.6 5.2 10/05/2005 13:30:00 11.7 0.9 13.3 9.1 11.8 1 13.7 9.1 25 4 26 305 5.3 0 5.6 5.2 10/05/2005 13:40:00 10.9 1 12.6 8.4 10.9 1 13 8.4 34 5 40 305 5.4 0 5.6 5.2 10/05/2005 13:50:00 11.2 1 13 8.4 11.1 1 13.3 8.4 27 5 24 305 5.4 0 5.6 5.4 10/05/2005 14:00:00 11.1 0.7 13 9.1 11.2 0.8 13 9.1 21 4 24 305 5.4 0 5.6 5.2 10/05/2005 14:10:00 10.9 1 13 8.8 11 1.1 12.6 8 22 5 20 305 5.4 0 5.6 5.2 10/05/2005 14:20:00 10.9 0.8 13 8.4 11 0.9 13 8.8 22 4 20 305 5.4 0 5.6 5.2 10/05/2005 14:30:00 11.2 0.9 13 8.8 11.2 1 13.3 8.8 23 5 25 305 5.5 0 5.9 5.4 10/05/2005 14:40:00 11.6 0.6 13.3 10.3 11.7 0.7 13.7 9.5 24 4 18 305 5.4 0 5.6 5.4 10/05/2005 14:50:00 11.7 0.8 13.3 9.1 11.7 0.9 13.7 9.1 23 4 21 305 5.4 0 5.6 5.4 10/05/2005 15:00:00 11.5 0.8 13.3 9.5 11.5 0.9 13.7 9.5 25 5 21 305 5.4 0 5.9 5.4 10/05/2005 15:10:00 11.6 0.7 13.3 9.1 11.6 0.8 13.7 9.1 23 4 29 305 5.5 0 5.9 5.4 10/05/2005 15:20:00 11.5 0.8 13.3 9.5 11.7 0.8 13.3 9.5 21 4 26 305 5.4 0 5.6 5.2 10/05/2005 15:30:00 11.3 0.7 13 9.5 11.5 0.8 13.3 8.8 17 4 18 305 5.3 0 5.4 5.2 10/05/2005 15:40:00 12.3 0.8 13.7 10.3 12.3 0.8 14.1 9.5 18 4 16 305 5.2 0 5.6 4.9 10/05/2005 15:50:00 11.5 0.9 13 9.1 11.6 0.9 13.3 9.1 18 4 21 305 5.3 0 5.6 5.2 10/05/2005 16:00:00 11.7 0.7 13.3 9.9 11.7 0.7 13.3 9.5 21 5 25 305 5.2 0 5.6 4.9 10/05/2005 16:10:00 12.3 0.8 14.5 10.3 12.4 0.9 14.5 9.1 25 4 20 305 5.2 0 5.4 4.9 10/05/2005 16:20:00 12.6 0.9 15.3 10.3 12.7 1 14.9 10.3 24 4 24 305 5.2 0 5.4 4.9 10/05/2005 16:30:00 12.9 0.9 15.3 10.7 12.9 1 15.6 9.9 23 4 21 305 5.1 0 5.4 4.9 10/05/2005 16:40:00 12.9 0.9 14.9 9.9 12.9 1 15.3 9.9 26 4 27 305 5.1 0 5.4 4.9 10/05/2005 16:50:00 13.2 0.8 14.9 11.1 13.2 0.8 15.3 10.7 23 5 26 305 5 0.1 5.4 4.9 10/05/2005 17:00:00 12.3 1 14.5 9.5 12.4 1.2 14.9 9.5 23 4 25 305 5 0 5.4 4.9 10/05/2005 17:10:00 11.9 1 14.1 9.5 12 1.1 14.1 8.8 22 4 18 305 5 0.1 5.4 4.9 10/05/2005 17:20:00 12.8 0.7 14.9 10.7 12.9 0.9 14.9 10.3 23 3 22 305 5 0.1 5.4 4.9 10/05/2005 17:30:00 12.7 0.8 14.9 10.7 12.7 0.9 14.9 10.3 25 4 23 305 5.1 0 5.4 4.9 10/05/2005 17:40:00 12.8 0.8 14.5 9.9 12.6 1 14.9 9.1 27 4 25 305 5 0.1 5.4 4.9 10/05/2005 17:50:00 12.6 0.9 14.5 9.9 12.5 1 14.9 9.9 27 3 25 305 5 0.1 5.4 4.9 10/05/2005 18:00:00 12.7 1 14.9 9.9 12.6 1.1 14.9 9.5 27 4 28 305 5 0.1 5.4 4.9 10/05/2005 18:10:00 11.8 1 14.1 9.5 11.8 1.1 13.7 8.8 31 4 27 305 5 0.1 5.4 4.9 10/05/2005 18:20:00 12 1 14.1 9.1 11.9 1 14.1 8.8 29 4 25 305 4.9 0 5.4 4.9 10/05/2005 18:30:00 12.1 1 14.9 9.9 11.9 1 14.9 9.5 29 4 32 305 4.9 0 5.4 4.9 10/05/2005 18:40:00 11.9 0.8 13.7 9.5 11.7 1 13.7 9.1 32 4 39 305 4.9 0.1 5.4 4.9 10/05/2005 18:50:00 12.7 1 14.9 9.5 12.6 1.1 14.5 9.1 32 3 32 305 4.9 0 5.4 4.9 10/05/2005 19:00:00 12 1 14.5 9.5 12 1.1 14.5 9.1 30 4 27 305 4.9 0 5.4 4.9 10/05/2005 19:10:00 11.2 0.8 13 9.1 11.1 0.9 13.3 8.8 30 4 32 305 4.9 0 5.4 4.9 10/05/2005 19:20:00 12.3 0.6 13.7 10.3 12.3 0.7 14.1 10.3 30 3 32 305 4.9 0 5.4 4.7 10/05/2005 19:30:00 11.7 0.9 14.1 9.5 11.7 0.9 13.7 9.5 27 4 33 305 4.9 0 5.4 4.9 10/05/2005 19:40:00 12.2 0.7 14.1 10.3 12.2 0.7 14.1 10.3 27 4 25 305 4.9 0 5.4 4.7 10/05/2005 19:50:00 11.3 1 13.7 9.1 11.2 1.1 13.7 8.8 28 4 25 305 4.8 0 5.4 4.7 10/05/2005 20:00:00 11.9 0.8 13.3 9.9 11.8 0.9 13.7 9.5 30 4 24 305 4.8 0 5.4 4.7 10/05/2005 20:10:00 12.3 0.8 14.1 10.3 12.2 0.9 14.1 10.3 31 3 33 305 4.8 0 5.2 4.7 10/05/2005 20:20:00 12.7 0.8 14.5 10.3 12.6 0.8 14.5 9.9 31 3 32 305 4.8 0 5.2 4.7 10/05/2005 20:30:00 12.1 0.9 14.1 9.5 12 1 14.5 9.5 33 4 38 305 4.7 0 5.2 4.4 10/05/2005 20:40:00 12.2 1 14.1 8.8 12 1 14.9 8.8 29 4 32 305 4.8 0.1 5.2 4.7 10/05/2005 20:50:00 12 0.8 13.3 9.9 12 0.8 13.7 9.9 30 4 25 305 4.7 0.1 5.4 4.4 10/05/2005 21:00:00 11.5 0.7 13 9.1 11.4 0.8 13.3 9.1 32 5 27 305 4.7 0.1 5.2 4.4 10/05/2005 21:10:00 11.7 0.8 13.3 9.5 11.6 0.9 13.7 9.1 32 5 30 305 4.7 0.1 5.2 4.4 10/05/2005 21:20:00 11.4 0.8 13.3 8.8 11.3 0.9 13.3 8.4 34 4 39 305 4.7 0.1 5.2 4.4 10/05/2005 21:30:00 11.5 0.8 13 9.5 11.3 0.9 13.3 8.8 34 4 32 305 4.5 0.1 4.9 4.4 10/05/2005 21:40:00 11.1 0.8 12.6 8.8 11.1 0.8 12.6 8.8 32 4 28 305 4.5 0.1 5.2 4.4 10/05/2005 21:50:00 11.2 0.7 13 9.1 11.1 0.8 12.6 8.8 33 5 29 305 4.5 0.1 4.9 4.4 10/05/2005 22:00:00 11.5 0.7 13 9.5 11.4 0.8 13 9.1 35 3 32 305 4.6 0.1 4.9 4.4 10/05/2005 22:10:00 11.4 0.8 13 9.1 11.3 0.8 13 9.1 33 3 37 305 4.5 0.1 4.9 4.4 10/05/2005 22:20:00 10.9 0.6 12.2 8.8 10.8 0.7 12.2 8.8 32 4 27 305 4.5 0.1 4.9 4.4 10/05/2005 22:30:00 10.7 0.7 12.6 8.4 10.7 0.8 12.6 8.8 35 5 27 305 4.5 0.1 4.9 4.4 10/05/2005 22:40:00 10.4 0.8 12.2 8.4 10.4 0.9 12.2 7.6 30 4 29 305 4.6 0.1 5.2 4.4 10/05/2005 22:50:00 11.1 0.8 12.6 8.8 11.1 0.9 13 8.4 30 3 33 305 4.5 0.1 4.9 4.4 10/05/2005 23:00:00 11 0.8 13 8.4 10.9 0.8 13.3 8.4 29 4 30 305 4.5 0.1 4.9 4.4 10/05/2005 23:10:00 11.1 0.9 13 8.8 11 0.9 13 8.4 27 5 22 305 4.5 0.1 4.9 4.4 10/05/2005 23:20:00 10.9 0.6 12.2 9.1 11 0.7 12.6 8.8 26 5 34 305 4.4 0.1 4.9 4.4 10/05/2005 23:30:00 10.6 0.8 12.2 8.4 10.6 1 12.6 8 26 4 24 305 4.5 0.1 4.9 4.4 10/05/2005 23:40:00 10.9 0.7 12.6 8.8 10.8 0.8 12.6 8.4 28 5 29 305 4.5 0.1 4.9 4.4 10/05/2005 23:50:00 10.9 0.8 12.6 8.8 10.9 0.9 13 8.4 25 4 26 305 4.5 0.1 4.9 4.4 10/06/2005 00:00:00 10.7 0.8 12.2 8.8 10.6 0.9 12.6 8 25 4 27 305 4.5 0.1 4.9 4.4 10/06/2005 00:10:00 10.9 0.8 12.6 8.4 10.9 0.8 12.6 8.4 26 4 25 305 4.5 0.1 4.9 4.4 10/06/2005 00:20:00 10.4 0.8 13 8.8 10.4 0.8 13 8.4 29 4 25 305 4.5 0.1 4.9 4.4 10/06/2005 00:30:00 11.2 0.7 12.6 8.8 11.3 0.8 13 8.4 24 3 25 305 4.5 0.1 4.9 4.4 10/06/2005 00:40:00 10.2 0.7 11.5 8 10.3 0.8 11.8 8 24 4 24 305 4.4 0.1 4.9 4.4 10/06/2005 00:50:00 10.1 0.5 11.5 8.8 10 0.6 11.5 8 27 3 27 305 4.5 0.2 4.9 4.4 10/06/2005 01:00:00 9.9 0.6 11.5 8 10 0.7 11.5 8 22 4 21 305 4.4 0.2 4.9 4.2 10/06/2005 01:10:00 9.8 0.8 11.5 7.6 9.9 0.8 11.8 7.2 20 4 22 305 4.4 0.1 4.9 4.4 10/06/2005 01:20:00 10 0.9 11.8 7.6 10 0.9 12.2 7.6 21 4 20 305 4.4 0.1 4.9 4.4 10/06/2005 01:30:00 9.8 0.7 11.5 8 9.9 0.7 11.5 7.6 21 4 18 305 4.4 0.1 4.9 4.2 10/06/2005 01:40:00 10 0.7 11.5 8 10.1 0.6 11.5 8.4 17 3 12 305 4.4 0.1 4.9 4.2 10/06/2005 01:50:00 10.1 0.6 11.8 8.4 10.2 0.7 11.8 8 20 3 24 305 4.4 0.1 4.9 4.2 10/06/2005 02:00:00 9.9 0.7 11.5 7.6 10 0.7 11.5 7.6 19 3 22 305 4.4 0.1 4.9 4.2 10/06/2005 02:10:00 10.3 0.6 11.5 8.4 10.4 0.7 11.8 8.4 18 3 26 305 4.4 0 4.9 4.2 10/06/2005 02:20:00 9.9 0.7 11.5 8 10.1 0.7 11.5 8 19 4 19 305 4.3 0 4.9 4.2 10/06/2005 02:30:00 9.9 0.6 11.5 8.4 10.1 0.6 11.5 8 16 3 11 305 4.3 0 4.9 4.2 10/06/2005 02:40:00 9.4 0.6 10.7 7.2 9.5 0.6 11.1 7.2 19 3 16 305 4.2 0 4.7 4.2 10/06/2005 02:50:00 8.6 0.6 9.9 6.8 8.7 0.7 10.3 6.5 21 6 25 305 4.3 0 4.7 4.2 10/06/2005 03:00:00 9.4 0.7 10.7 7.6 9.6 0.8 11.1 6.8 17 4 9 305 4.3 0.1 4.7 4.2 10/06/2005 03:10:00 9.4 0.6 11.1 7.6 9.5 0.7 11.5 7.6 18 5 24 305 4.3 0.1 4.7 4.2 10/06/2005 03:20:00 9 0.5 10.3 7.6 9.2 0.6 10.7 7.2 3 6 7 305 3.9 0.2 4.7 3.4 10/06/2005 03:30:00 9.3 0.8 11.1 7.2 9.5 0.8 11.5 7.2 3 5 359 305 3.8 0.1 4.4 3.4 10/06/2005 03:40:00 9.8 0.7 11.8 8 10 0.7 11.8 8.4 3 3 6 305 3.7 0.1 4.2 3.4 10/06/2005 03:50:00 9.3 0.7 10.7 7.6 9.5 0.7 11.1 7.6 1 5 0 305 3.7 0 4.2 3.4 10/06/2005 04:00:00 9.6 1.1 11.8 7.6 9.7 1.2 12.2 6.1 4 5 9 305 3.6 0 4.2 3.4 10/06/2005 04:10:00 9.9 0.7 11.5 7.6 10.2 0.7 11.8 8.4 7 4 10 305 3.6 0 3.9 3.4 10/06/2005 04:20:00 10 1 11.8 7.2 10.2 1 11.8 7.6 6 5 6 305 3.6 0.1 4.2 3.2 10/06/2005 04:30:00 10.4 0.7 11.8 8.4 10.7 0.7 12.2 8.4 6 3 5 305 3.5 0.1 3.7 3.2 10/06/2005 04:40:00 9.4 0.7 11.5 7.2 9.6 0.7 11.5 7.6 2 5 3 305 3.4 0.1 3.7 3.2 10/06/2005 04:50:00 9.2 0.6 10.7 7.6 9.5 0.7 11.1 7.6 7 4 8 305 3.6 0.1 3.9 3.2 10/06/2005 05:00:00 9.3 0.6 10.7 7.6 9.6 0.7 11.1 6.8 7 3 8 305 3.6 0.1 4.2 3.2 10/06/2005 05:10:00 10.1 0.5 11.5 8.4 10.4 0.6 11.8 8.8 8 3 12 305 3.5 0.1 3.9 3.4 10/06/2005 05:20:00 9.5 0.5 10.7 7.6 9.8 0.6 11.5 7.6 8 3 7 305 3.6 0.1 3.9 3.4 10/06/2005 05:30:00 9.1 0.6 10.7 7.2 9.3 0.7 11.1 7.2 5 3 2 305 3.6 0 3.9 3.4 10/06/2005 05:40:00 9.1 0.7 11.1 7.2 9.3 0.8 11.5 7.2 7 4 8 305 3.7 0 4.2 3.4 10/06/2005 05:50:00 9.8 0.6 11.5 8 10 0.6 11.5 8.4 6 4 359 305 3.6 0.1 4.2 3.4 10/06/2005 06:00:00 9.7 0.5 11.1 8.4 10 0.5 11.1 8 8 4 5 305 3.6 0 3.9 3.4 10/06/2005 06:10:00 9.3 0.6 10.3 7.6 9.5 0.7 11.1 7.6 13 3 10 305 3.6 0.1 3.9 3.4 10/06/2005 06:20:00 9.7 0.5 11.1 8.8 9.9 0.5 11.1 8.4 13 3 16 305 3.7 0 4.2 3.4 10/06/2005 06:30:00 9 0.6 10.7 6.8 9.1 0.6 11.1 7.2 14 5 19 305 3.7 0 4.2 3.4 10/06/2005 06:40:00 9.5 0.6 11.1 7.6 9.8 0.6 11.5 8 9 3 7 305 3.7 0 4.2 3.4 10/06/2005 06:50:00 9.2 0.5 10.7 7.6 9.4 0.6 10.7 7.6 11 3 11 305 3.8 0 4.2 3.7 10/06/2005 07:00:00 9.1 0.5 10.3 7.2 9.4 0.5 10.7 8 11 3 12 305 3.8 0 4.2 3.7 10/06/2005 07:10:00 8.6 0.8 9.9 6.1 8.9 0.9 10.7 6.1 14 4 14 305 3.8 0 4.2 3.7 10/06/2005 07:20:00 9.2 0.6 10.7 7.2 9.5 0.7 11.1 6.8 13 4 8 305 3.8 0 4.2 3.7 10/06/2005 07:30:00 9.3 0.7 11.1 7.2 9.5 0.7 11.5 7.6 15 5 6 305 3.9 0.1 4.4 3.7 10/06/2005 07:40:00 9.5 0.7 11.1 7.6 9.7 0.7 11.5 7.6 18 4 16 305 3.9 0.1 4.4 3.7 10/06/2005 07:50:00 9.3 0.6 10.7 8 9.5 0.6 11.1 8 20 4 17 305 3.9 0.1 4.4 3.7 10/06/2005 08:00:00 9.5 0.7 11.1 7.6 9.7 0.7 11.5 7.6 24 3 22 305 3.9 0.1 4.4 3.7 10/06/2005 08:10:00 10 0.5 11.5 8.4 10.1 0.6 11.5 8 27 3 26 305 3.9 0.1 4.4 3.7 10/06/2005 08:20:00 9.6 0.6 10.7 8 9.6 0.6 11.1 8 28 3 27 305 4 0.1 4.4 3.7 10/06/2005 08:30:00 8.6 0.6 9.9 6.8 8.7 0.6 9.9 6.5 29 4 31 305 4 0.1 4.4 3.7 10/06/2005 08:40:00 9 0.5 9.9 7.6 9 0.5 10.3 7.6 27 3 27 305 4 0.1 4.4 3.9 10/06/2005 08:50:00 8.8 0.6 10.3 7.2 9 0.7 10.7 6.8 26 4 22 305 4 0.1 4.4 3.9 10/06/2005 09:00:00 8.6 0.6 9.5 7.2 8.7 0.6 10.3 7.2 28 4 31 305 4.1 0 4.4 3.9 10/06/2005 09:10:00 8.7 0.6 10.7 7.2 8.6 0.7 10.7 7.2 30 3 31 305 4.1 0.1 4.4 3.9 10/06/2005 09:20:00 8.6 0.6 9.9 6.8 8.7 0.6 9.9 6.5 37 5 35 305 4.2 0.1 4.7 4.2 10/06/2005 09:30:00 8.4 0.5 9.5 6.8 8.6 0.5 9.5 7.2 35 4 32 305 4.2 0 4.7 4.2 10/06/2005 09:40:00 8.2 0.5 9.1 6.8 8.3 0.5 9.1 6.5 32 3 25 305 4.3 0 4.7 4.2 10/06/2005 09:50:00 7.6 0.5 8.8 6.5 7.8 0.6 9.1 6.5 43 4 38 305 4.2 0 4.7 4.2 10/06/2005 10:00:00 7.7 0.5 8.8 6.1 7.8 0.5 9.1 6.5 38 4 33 305 4.2 0 4.7 4.2 10/06/2005 10:10:00 7.3 0.5 8.4 5.7 7.4 0.6 8.4 5.7 37 3 30 305 4.3 0 4.7 4.2 10/06/2005 10:20:00 6.7 0.5 8 4.9 6.7 0.6 8 4.9 39 3 38 305 4.4 0.1 4.7 4.2 10/06/2005 10:30:00 6.3 0.4 7.2 5.3 6.4 0.5 7.2 4.9 38 4 39 305 4.5 0.1 4.9 4.4 10/06/2005 10:40:00 6.4 0.3 6.8 5.3 6.5 0.4 7.2 4.9 40 3 41 305 4.7 0.1 5.2 4.4 10/06/2005 10:50:00 6 0.4 7.2 4.9 6.1 0.5 7.2 4.9 48 3 50 305 4.8 0 5.4 4.7 10/06/2005 11:00:00 5.7 0.4 6.5 4.9 5.8 0.4 6.8 4.9 52 2 51 305 4.8 0 5.4 4.7 10/06/2005 11:10:00 5.2 0.5 6.1 3.8 5.3 0.5 6.5 4.2 54 6 57 305 4.9 0.1 5.4 4.9 10/06/2005 11:20:00 5 0.4 5.7 3.8 4.9 0.5 6.1 3.8 64 4 61 305 5.2 0 5.6 4.9 10/06/2005 11:30:00 4.8 0.3 5.7 3.8 4.7 0.4 5.7 3.8 67 5 68 305 5.3 0 5.6 5.2 10/06/2005 11:40:00 5.3 0.4 6.1 4.2 5.2 0.5 6.1 3.8 68 4 66 305 5.4 0 5.6 5.4 10/06/2005 11:50:00 5.7 0.4 6.5 4.9 5.6 0.4 6.5 4.6 70 3 73 305 5.5 0 5.6 5.4 10/06/2005 12:00:00 5.8 0.3 6.5 4.2 5.7 0.4 6.5 3.8 72 3 69 305 5.6 0 5.9 5.4 10/06/2005 12:10:00 5.3 0.4 6.1 4.2 5.2 0.5 6.1 3.8 72 3 70 305 5.6 0 5.9 5.6 10/06/2005 12:20:00 5.2 0.4 6.5 4.2 5.1 0.5 6.5 3.8 73 4 74 305 5.8 0 5.9 5.6 10/06/2005 12:30:00 5 0.4 6.1 3.8 4.9 0.4 5.7 3.8 70 5 73 305 5.8 0 5.9 5.6 10/06/2005 12:40:00 4.9 0.4 6.1 3.4 4.9 0.5 6.1 3.8 69 5 70 305 5.8 0 5.9 5.6 10/06/2005 12:50:00 4.5 0.4 5.7 3.4 4.5 0.5 5.7 3.4 68 6 70 305 5.9 0 6.1 5.9 10/06/2005 13:00:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 65 6 65 305 6 0 6.1 5.9 10/06/2005 13:10:00 4.1 0.4 4.9 3 4.1 0.4 4.9 3 61 5 62 305 5.9 0 6.1 5.9 10/06/2005 13:20:00 3.6 0.4 4.6 2.6 3.7 0.4 4.6 2.3 56 6 52 305 5.8 0 5.9 5.6 10/06/2005 13:30:00 3.8 0.3 4.6 3 3.8 0.4 4.6 2.6 59 5 59 305 5.9 0 5.9 5.6 10/06/2005 13:40:00 3.7 0.4 4.6 2.6 3.8 0.4 4.6 2.6 56 6 52 305 5.9 0 5.9 5.6 10/06/2005 13:50:00 3.6 0.4 4.2 2.6 3.6 0.4 4.6 2.6 56 6 57 305 6 0 6.1 5.9 10/06/2005 14:00:00 4 0.4 4.9 2.6 4 0.4 4.9 3 56 5 53 305 6 0 6.1 5.9 10/06/2005 14:10:00 4.2 0.3 4.9 3 4.3 0.3 4.9 3.4 61 5 68 305 6.1 0 6.4 5.9 10/06/2005 14:20:00 4.3 0.3 4.9 3.4 4.3 0.4 4.9 3.4 61 5 62 305 6.1 0 6.4 5.9 10/06/2005 14:30:00 4.6 0.3 5.3 3.4 4.6 0.4 5.3 3.4 64 4 66 305 6.2 0 6.4 6.1 10/06/2005 14:40:00 4.6 0.3 5.3 3.8 4.5 0.3 5.3 3.4 62 4 69 305 6.3 0 6.4 6.1 10/06/2005 14:50:00 4.7 0.3 5.3 3.8 4.7 0.3 5.3 3.4 63 4 68 305 6.2 0 6.4 5.9 10/06/2005 15:00:00 4.3 0.3 4.9 3.4 4.3 0.3 4.9 3.4 61 5 63 305 6.1 0 6.4 5.9 10/06/2005 15:10:00 4.1 0.4 4.9 3 4.1 0.4 4.9 3 59 5 58 305 6.1 0 6.4 5.9 10/06/2005 15:20:00 3.9 0.3 4.9 3 3.9 0.3 4.6 3 58 5 57 305 6.3 0 6.7 6.1 10/06/2005 15:30:00 3.8 0.3 4.6 2.6 3.8 0.4 4.6 3 56 4 56 305 6.1 0 6.4 5.9 10/06/2005 15:40:00 3.8 0.3 4.6 3 3.9 0.3 4.6 3 56 3 55 305 6.2 0 6.4 5.9 10/06/2005 15:50:00 3.9 0.3 4.6 3.4 3.9 0.3 4.9 3 56 5 61 305 6.1 0 6.9 5.9 10/06/2005 16:00:00 3.9 0.3 4.6 3 4 0.3 4.9 3 56 4 49 305 6.1 0 6.4 5.9 10/06/2005 16:10:00 3.9 0.3 4.6 2.6 4 0.3 4.6 3 52 4 53 305 6.1 0.1 6.4 5.9 10/06/2005 16:20:00 3.9 0.2 4.6 3.4 3.9 0.3 4.6 2.6 52 3 51 305 6.1 0 6.4 5.9 10/06/2005 16:30:00 3.7 0.3 4.2 2.6 3.8 0.3 4.6 2.6 49 3 48 305 6.1 0 6.7 5.9 10/06/2005 16:40:00 4.1 0.3 4.6 3.4 4.1 0.3 4.9 3 51 3 54 305 6.1 0 6.4 5.9 10/06/2005 16:50:00 4.3 0.2 4.9 3.4 4.3 0.3 4.9 3.4 51 3 55 305 6.1 0 6.7 5.9 10/06/2005 17:00:00 4.2 0.2 4.6 3.4 4.3 0.3 4.9 3.4 52 3 50 305 6.1 0 6.4 5.9 10/06/2005 17:10:00 4 0.3 4.6 3.4 4 0.3 4.6 3 50 4 48 305 6.1 0 6.4 5.9 10/06/2005 17:20:00 3.7 0.3 4.6 3 3.8 0.4 4.6 2.6 53 4 53 305 6.1 0 6.1 5.9 10/06/2005 17:30:00 4 0.2 4.6 3.4 3.9 0.3 4.6 3 53 4 58 305 6 0 6.4 5.9 10/06/2005 17:40:00 3.6 0.5 4.6 2.3 3.7 0.5 4.6 2.3 50 4 45 305 6 0 6.1 5.9 10/06/2005 17:50:00 2.8 0.4 3.8 1.5 2.8 0.3 3.4 1.9 47 5 51 305 6.1 0 6.4 5.9 10/06/2005 18:00:00 2.9 0.4 3.8 1.9 2.8 0.4 4.2 2.3 49 6 42 305 6.1 0 6.4 5.9 10/06/2005 18:10:00 4 0.6 4.9 2.3 3.9 0.6 4.9 2.3 46 5 47 305 6 0 6.1 5.9 10/06/2005 18:20:00 4.8 0.3 5.3 4.2 4.6 0.3 5.3 3.8 45 3 47 305 6 0 5.9 5.9 10/06/2005 18:30:00 5 0.3 5.7 4.2 4.9 0.4 5.7 3.8 48 3 48 305 5.8 0 5.9 5.6 10/06/2005 18:40:00 4.9 0.3 5.7 4.2 4.8 0.3 5.7 3.8 48 3 52 305 5.7 0 5.9 5.6 10/06/2005 18:50:00 4.9 0.3 5.7 4.2 4.8 0.3 5.7 3.8 47 2 45 305 5.6 0 5.9 5.4 10/06/2005 19:00:00 5 0.2 5.7 4.6 5 0.3 5.7 4.2 45 2 46 305 5.4 0 5.6 5.4 10/06/2005 19:10:00 5.3 0.3 5.7 4.6 5.3 0.3 5.7 4.2 49 3 43 305 5.3 0 5.4 5.2 10/06/2005 19:20:00 5.2 0.3 6.1 4.2 5.2 0.3 6.1 4.2 47 3 47 305 5 0 5.4 4.9 10/06/2005 19:30:00 5.4 0.2 6.1 4.9 5.4 0.3 6.1 4.9 48 3 53 305 4.8 0 4.9 4.9 10/06/2005 19:40:00 5.7 0.3 6.1 4.9 5.6 0.3 6.1 4.9 48 3 47 305 4.8 0 4.9 4.7 10/06/2005 19:50:00 5.7 0.3 6.1 4.9 5.6 0.3 6.5 4.6 50 3 48 305 4.8 0 4.9 4.7 10/06/2005 20:00:00 6.1 0.3 6.8 5.3 6.1 0.3 6.8 4.9 48 3 55 305 4.8 0 4.9 4.7 10/06/2005 20:10:00 5.8 0.4 6.8 4.9 5.8 0.4 6.8 4.9 48 3 45 305 4.8 0 4.9 4.7 10/06/2005 20:20:00 5.7 0.3 6.5 4.6 5.6 0.4 6.5 4.9 49 3 46 305 4.7 0 4.9 4.7 10/06/2005 20:30:00 5.6 0.4 6.5 4.6 5.6 0.4 6.5 4.6 50 3 48 305 4.7 0 4.9 4.4 10/06/2005 20:40:00 5.4 0.4 6.5 4.6 5.5 0.4 6.5 4.6 47 3 51 305 4.7 0 4.7 4.7 10/06/2005 20:50:00 5.7 0.3 6.1 4.9 5.6 0.3 6.5 4.9 44 2 41 305 4.7 0 4.9 4.7 10/06/2005 21:00:00 5.5 0.3 6.1 4.9 5.5 0.3 6.5 4.6 46 3 44 305 4.7 0 4.9 4.7 10/06/2005 21:10:00 5.4 0.4 6.1 4.2 5.4 0.4 6.1 4.2 45 3 47 305 4.7 0 4.9 4.7 10/06/2005 21:20:00 4.9 0.3 5.7 4.2 5 0.3 5.7 4.2 41 2 44 305 4.7 0 4.9 4.7 10/06/2005 21:30:00 5 0.3 5.7 4.2 5 0.3 5.7 4.2 41 3 44 305 4.7 0 4.9 4.4 10/06/2005 21:40:00 5.3 0.3 5.7 4.6 5.3 0.3 6.1 4.6 40 3 43 305 4.7 0 4.9 4.4 10/06/2005 21:50:00 5.3 0.3 6.1 4.6 5.3 0.4 6.1 4.6 42 3 39 305 4.7 0 4.9 4.7 10/06/2005 22:00:00 5 0.3 5.7 4.2 5 0.3 5.7 4.2 42 4 49 305 4.7 0 4.9 4.4 10/06/2005 22:10:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 4.2 44 2 45 305 4.7 0 4.9 4.4 10/06/2005 22:20:00 4.9 0.3 5.7 4.2 5 0.3 5.7 4.2 44 2 43 305 4.7 0 4.9 4.4 10/06/2005 22:30:00 5.2 0.3 6.1 4.6 5.2 0.3 6.1 4.2 43 4 45 305 4.7 0 4.9 4.4 10/06/2005 22:40:00 5.4 0.3 6.1 4.6 5.4 0.3 6.1 4.6 38 2 40 305 4.7 0 4.9 4.7 10/06/2005 22:50:00 5.2 0.3 6.1 4.2 5.2 0.4 6.1 4.2 42 3 46 305 4.7 0 4.9 4.7 10/06/2005 23:00:00 4.5 0.6 6.1 3 4.5 0.6 5.7 3 56 7 67 305 4.5 0.2 4.9 4.2 10/06/2005 23:10:00 4.6 0.4 5.7 3.8 4.6 0.3 5.3 3.8 63 4 64 305 4.3 0 4.7 4.2 10/06/2005 23:20:00 4.6 0.5 5.7 3.4 4.6 0.4 6.1 3.4 63 4 64 305 4.4 0 4.7 4.2 10/06/2005 23:30:00 4.5 0.3 5.3 3.8 4.6 0.3 5.7 3.8 62 4 58 305 4.4 0 4.7 4.2 10/06/2005 23:40:00 4.5 0.4 5.7 3.4 4.5 0.5 5.7 3.8 57 4 54 305 4.3 0 4.7 4.2 10/06/2005 23:50:00 4.6 0.6 5.7 3.4 4.6 0.6 5.7 3.4 54 3 56 305 4.2 0 4.7 4.2 10/07/2005 00:00:00 5.7 0.4 6.5 4.9 5.7 0.4 6.5 4.9 49 2 50 305 4.4 0.1 4.9 4.2 10/07/2005 00:10:00 5.7 0.3 6.5 4.6 5.6 0.4 6.5 4.6 49 3 48 305 4.7 0 5.2 4.4 10/07/2005 00:20:00 5.9 0.6 7.6 4.6 5.9 0.6 7.2 4.6 49 3 48 305 4.6 0 4.9 4.4 10/07/2005 00:30:00 6 0.3 7.2 5.3 6 0.4 7.2 4.9 49 3 51 305 4.7 0 4.9 4.4 10/07/2005 00:40:00 6.7 0.3 7.6 5.7 6.7 0.4 7.6 5.7 51 3 55 305 4.7 0 5.2 4.7 10/07/2005 00:50:00 6.9 0.4 8 6.1 6.9 0.5 8 5.7 53 4 57 305 4.8 0 5.2 4.7 10/07/2005 01:00:00 6.8 0.6 8 5.3 6.7 0.6 8 5.3 57 3 58 305 4.7 0 5.2 4.4 10/07/2005 01:10:00 6.2 0.7 8 4.6 6.2 0.8 8 4.9 54 4 53 305 4.7 0 5.2 4.4 10/07/2005 01:20:00 6.9 0.7 8.4 4.9 6.8 0.7 8.4 4.9 55 5 54 305 4.8 0 5.4 4.7 10/07/2005 01:30:00 7.6 0.6 8.8 5.7 7.5 0.6 8.8 4.9 56 4 61 305 4.8 0 5.4 4.7 10/07/2005 01:40:00 7 0.5 8 5.7 7 0.5 8 5.7 49 4 44 305 4.9 0 5.4 4.7 10/07/2005 01:50:00 6.9 0.4 7.6 6.1 6.9 0.4 7.6 5.7 45 3 46 305 4.9 0.1 5.4 4.9 10/07/2005 02:00:00 6.5 0.3 7.2 5.3 6.5 0.4 7.2 5.7 47 3 46 305 4.9 0.1 5.4 4.9 10/07/2005 02:10:00 7.2 0.6 8.4 5.7 7.4 0.6 8.8 5.7 44 4 48 305 5 0.1 5.4 4.9 10/07/2005 02:20:00 7.8 0.5 9.1 6.5 7.9 0.5 9.1 6.5 44 3 41 305 5 0.1 5.4 4.9 10/07/2005 02:30:00 7.4 0.4 8.8 6.1 7.6 0.4 8.8 6.5 45 3 42 305 4.9 0.1 5.4 4.9 10/07/2005 02:40:00 7 0.4 8 6.1 7.1 0.4 8 6.1 48 3 47 305 4.9 0 5.4 4.7 10/07/2005 02:50:00 7.4 0.5 8.4 6.1 7.4 0.5 8.8 5.7 47 3 48 305 4.9 0 5.4 4.7 10/07/2005 03:00:00 7.6 0.4 8.8 6.8 7.5 0.4 8.8 6.5 50 3 47 305 4.9 0 5.4 4.9 10/07/2005 03:10:00 7.4 0.3 8 6.5 7.4 0.3 8.4 6.5 49 2 50 305 4.8 0 5.4 4.7 10/07/2005 03:20:00 7.3 0.5 8.4 6.1 7.3 0.5 8.4 6.1 50 3 51 305 4.8 0 5.4 4.7 10/07/2005 03:30:00 7.3 0.5 8.4 6.1 7.2 0.5 8.4 5.7 51 3 48 305 4.8 0 5.2 4.7 10/07/2005 03:40:00 8.1 0.4 8.8 7.2 8 0.4 8.8 6.8 49 2 48 305 4.9 0 5.4 4.7 10/07/2005 03:50:00 7.9 0.4 9.1 6.8 7.9 0.5 9.1 6.5 48 3 51 305 4.9 0 5.4 4.7 10/07/2005 04:00:00 7.7 0.4 8.8 6.5 7.6 0.5 9.1 6.1 56 4 61 305 4.8 0 5.4 4.7 10/07/2005 04:10:00 6.6 0.6 8 5.3 6.6 0.6 8 4.9 60 5 71 305 4.8 0 5.2 4.7 10/07/2005 04:20:00 5.9 0.5 7.2 4.9 6 0.5 7.2 4.9 59 3 54 305 4.7 0 5.2 4.4 10/07/2005 04:30:00 6.7 0.5 8 5.7 6.7 0.5 8 5.7 59 4 58 305 4.7 0 5.2 4.4 10/07/2005 04:40:00 6.5 0.6 8 4.9 6.4 0.6 8 4.9 57 4 53 305 4.7 0 5.2 4.4 10/07/2005 04:50:00 7 0.5 8.4 5.7 6.9 0.5 8 5.7 58 3 60 305 4.7 0.1 5.2 4.4 10/07/2005 05:00:00 6.7 0.5 8 5.3 6.6 0.5 8 5.7 59 3 58 305 4.7 0 5.2 4.4 10/07/2005 05:10:00 6.4 0.6 8 5.3 6.3 0.6 8 4.9 53 4 44 305 4.7 0 5.4 4.7 10/07/2005 05:20:00 7.5 0.4 8.4 6.5 7.4 0.4 8.4 6.1 40 3 36 305 4.9 0 5.4 4.7 10/07/2005 05:30:00 7.6 0.6 8.8 6.1 7.6 0.6 9.1 6.1 39 3 38 305 5 0.1 5.4 4.9 10/07/2005 05:40:00 7.6 0.4 8.4 6.8 7.5 0.5 8.4 6.1 44 3 43 305 4.9 0 5.4 4.7 10/07/2005 05:50:00 7.9 0.5 9.1 6.5 7.8 0.6 9.1 6.1 43 3 41 305 4.9 0 5.4 4.7 10/07/2005 06:00:00 7.9 0.5 9.1 6.5 7.8 0.5 9.5 6.5 45 4 48 305 4.8 0 5.4 4.7 10/07/2005 06:10:00 8 0.4 8.8 6.8 7.9 0.5 8.8 6.5 45 4 48 305 4.9 0.1 5.4 4.7 10/07/2005 06:20:00 7.4 0.4 8.4 6.5 7.3 0.4 8.4 6.5 44 2 46 305 4.8 0 5.4 4.7 10/07/2005 06:30:00 7.6 0.4 8.8 6.5 7.5 0.4 8.4 6.5 44 2 44 305 4.8 0 5.4 4.7 10/07/2005 06:40:00 6.8 0.5 8 5.7 6.7 0.5 8 5.7 46 3 44 305 4.8 0 5.4 4.7 10/07/2005 06:50:00 6.8 0.4 7.6 6.1 6.8 0.4 7.6 5.7 45 3 47 305 4.8 0 5.4 4.7 10/07/2005 07:00:00 6.7 0.4 7.6 5.7 6.7 0.4 7.6 5.3 44 3 40 305 4.8 0 5.4 4.7 10/07/2005 07:10:00 6.3 0.3 6.8 5.3 6.4 0.4 7.2 5.3 39 2 42 305 4.8 0 5.4 4.7 10/07/2005 07:20:00 6.1 0.4 6.8 5.3 6.2 0.4 6.8 4.9 38 2 41 305 4.8 0 5.4 4.7 10/07/2005 07:30:00 5.6 0.3 6.5 4.9 5.6 0.3 6.5 4.9 36 3 37 305 4.8 0 5.2 4.7 10/07/2005 07:40:00 6.1 0.3 6.8 5.3 6.1 0.3 6.8 5.3 30 2 30 305 4.7 0.1 5.2 4.7 10/07/2005 07:50:00 6.3 0.4 7.2 5.3 6.3 0.4 7.2 5.3 24 2 25 305 4.7 0 5.2 4.4 10/07/2005 08:00:00 6 0.3 6.5 4.9 6.1 0.3 6.8 4.9 22 2 23 305 4.7 0 5.2 4.7 10/07/2005 08:10:00 6.1 0.3 6.8 4.9 6.1 0.4 7.2 5.3 21 2 21 305 4.7 0.1 5.2 4.4 10/07/2005 08:20:00 5.8 0.4 6.8 4.9 5.9 0.4 6.8 5.3 18 2 22 305 4.7 0.1 5.2 4.4 10/07/2005 08:30:00 5.9 0.3 6.8 4.9 6.1 0.4 7.2 5.3 14 3 13 305 4.7 0.1 5.2 4.4 10/07/2005 08:40:00 6 0.3 6.8 5.3 6.1 0.3 6.8 5.3 16 2 13 305 4.7 0.1 5.2 4.4 10/07/2005 08:50:00 6.2 0.5 7.2 4.9 6.3 0.5 7.2 5.3 19 2 19 305 4.7 0.2 5.2 4.4 10/07/2005 09:00:00 6.8 0.4 7.6 5.7 6.8 0.4 8 5.7 17 2 16 305 4.7 0.1 5.2 4.4 10/07/2005 09:10:00 6.5 0.3 7.6 5.7 6.7 0.4 7.6 5.7 19 3 18 305 4.8 0 5.4 4.4 10/07/2005 09:20:00 6.1 0.3 7.2 5.3 6.3 0.3 6.8 5.3 21 3 19 305 4.8 0 5.4 4.7 10/07/2005 09:30:00 5.9 0.4 6.8 4.9 6 0.4 6.8 4.9 17 3 21 305 4.8 0 5.4 4.7 10/07/2005 09:40:00 6 0.4 7.2 4.9 6.2 0.4 7.6 5.3 17 2 15 305 4.8 0 5.4 4.7 10/07/2005 09:50:00 5.6 0.4 6.5 4.6 5.8 0.5 6.8 4.6 19 3 16 305 4.9 0.1 5.4 4.7 10/07/2005 10:00:00 5.2 0.3 6.1 4.6 5.4 0.3 6.1 4.6 18 3 16 305 4.9 0.1 5.4 4.7 10/07/2005 10:10:00 5.9 0.5 7.2 4.6 6 0.6 7.2 4.2 17 3 17 305 5 0.1 5.4 4.9 10/07/2005 10:20:00 5.4 0.4 6.5 4.2 5.5 0.4 6.1 4.6 20 3 25 305 5 0.2 5.4 4.9 10/07/2005 10:30:00 5.6 0.4 6.5 4.2 5.8 0.4 6.5 4.6 20 3 22 305 5.1 0.1 5.6 4.9 10/07/2005 10:40:00 5.6 0.5 6.8 4.6 5.7 0.5 6.8 4.6 18 3 23 305 5.3 0.1 5.6 4.9 10/07/2005 10:50:00 6.2 0.4 7.2 5.3 6.3 0.4 7.2 5.3 21 2 21 305 5.3 0 5.6 4.9 10/07/2005 11:00:00 6.1 0.6 7.2 4.9 6.2 0.6 7.6 4.6 19 5 24 305 5.5 0 5.9 5.2 10/07/2005 11:10:00 6.3 0.5 7.2 4.9 6.3 0.5 7.6 4.6 12 4 9 305 5.6 0.1 5.9 5.4 10/07/2005 11:20:00 6.8 0.5 8 5.3 7 0.5 8.4 5.7 9 2 10 305 5.5 0 5.6 5.4 10/07/2005 11:30:00 7.4 0.7 9.1 5.7 7.7 0.7 9.1 6.1 11 3 12 305 5.4 0 5.6 5.4 10/07/2005 11:40:00 7.7 0.5 8.8 6.5 7.8 0.5 9.1 6.5 11 3 11 305 5.2 0 5.6 5.2 10/07/2005 11:50:00 7.5 0.6 8.8 5.3 7.7 0.7 9.1 5.7 7 3 8 305 5.3 0 5.6 5.2 10/07/2005 12:00:00 8.1 0.6 9.5 6.1 8.4 0.6 9.9 6.8 7 3 5 305 5.1 0.1 5.4 4.9 10/07/2005 12:10:00 8.5 0.4 9.5 7.2 8.7 0.5 9.9 7.2 9 3 12 305 5 0.1 5.4 4.9 10/07/2005 12:20:00 7.6 0.5 8.8 6.5 7.8 0.5 8.8 6.5 9 3 8 305 5.2 0 5.6 4.9 10/07/2005 12:30:00 7.6 0.7 9.1 5.7 7.8 0.7 9.5 5.7 11 3 11 305 5.2 0 5.6 5.2 10/07/2005 12:40:00 7.5 0.6 8.8 6.1 7.7 0.6 9.1 6.1 12 3 12 305 5.2 0 5.6 5.2 10/07/2005 12:50:00 7.7 0.5 8.8 6.5 7.9 0.5 9.1 6.5 12 3 12 305 5.2 0 5.6 4.9 10/07/2005 13:00:00 8.4 0.6 9.9 6.8 8.6 0.6 9.9 6.8 11 3 11 305 5.2 0 5.6 4.9 10/07/2005 13:10:00 8.5 0.6 9.5 6.8 8.7 0.7 9.9 6.5 8 3 11 305 5.2 0 5.6 4.9 10/07/2005 13:20:00 8.4 0.6 9.9 6.8 8.5 0.7 9.9 6.5 9 3 11 305 5.2 0 5.6 4.9 10/07/2005 13:30:00 8.1 0.5 9.5 6.8 8.1 0.6 9.5 6.5 8 3 3 305 5.3 0 5.6 5.2 10/07/2005 13:40:00 8 0.7 9.1 6.1 8.2 0.7 9.9 6.1 9 3 10 305 5.4 0 5.6 5.4 10/07/2005 13:50:00 7.6 0.4 8.4 6.1 7.7 0.5 8.8 6.1 11 3 14 305 5.5 0.1 5.9 5.4 10/07/2005 14:00:00 7.1 0.5 8 5.7 7.1 0.5 8.4 5.7 17 5 13 305 5.5 0.1 5.9 5.4 10/07/2005 14:10:00 6.9 0.4 8 6.1 6.9 0.4 8 5.7 32 4 27 305 5.6 0.1 5.9 5.4 10/07/2005 14:20:00 6.9 0.5 8 5.7 6.9 0.5 8 5.7 32 2 35 305 5.5 0.1 5.9 5.4 10/07/2005 14:30:00 7 0.6 8.4 5.7 6.9 0.7 8.4 5.3 33 3 37 305 5.6 0.1 5.9 5.4 10/07/2005 14:40:00 7.3 0.4 8.4 6.1 7.3 0.4 8.4 5.7 33 3 33 305 5.6 0 5.9 5.4 10/07/2005 14:50:00 7.8 0.5 8.8 6.5 7.8 0.5 8.8 6.5 33 3 30 305 5.5 0 5.6 5.4 10/07/2005 15:00:00 7.1 0.5 8.8 5.7 7.3 0.5 8.8 5.7 29 3 30 305 5.2 0 5.6 5.2 10/07/2005 15:10:00 6.9 0.4 8 6.1 7.1 0.4 8.4 5.7 26 3 26 305 5.2 0 5.4 4.9 10/07/2005 15:20:00 7.6 0.5 8.8 6.1 7.7 0.5 9.1 6.5 26 3 25 305 5.2 0 5.4 4.9 10/07/2005 15:30:00 6.8 0.5 8 5.7 6.9 0.5 8 5.7 27 3 23 305 5.2 0 5.6 4.9 10/07/2005 15:40:00 6.2 0.4 7.2 5.3 6.3 0.5 7.6 5.3 27 3 26 305 5.3 0 5.6 5.2 10/07/2005 15:50:00 6.9 0.4 8 6.1 7 0.5 8.4 5.7 27 3 25 305 5.4 0 5.9 5.2 10/07/2005 16:00:00 6.5 0.4 7.2 5.7 6.6 0.4 7.6 5.3 31 2 29 305 5.3 0 5.6 5.2 10/07/2005 16:10:00 6.8 0.3 7.6 5.3 6.8 0.4 7.6 5.3 32 3 28 305 5.3 0 5.6 5.2 10/07/2005 16:20:00 6.9 0.4 7.6 6.1 7.1 0.4 8 6.1 33 3 29 305 5.3 0 5.6 5.2 10/07/2005 16:30:00 6.9 0.4 7.6 5.7 7.1 0.4 8 5.3 37 3 43 305 5.3 0 5.6 5.2 10/07/2005 16:40:00 7.3 0.4 8.4 6.5 7.4 0.4 8.4 6.5 32 4 25 305 5.2 0 5.6 4.9 10/07/2005 16:50:00 7.3 0.4 8.4 6.1 7.2 0.4 8.4 5.7 31 3 29 305 5.2 0 5.6 4.9 10/07/2005 17:00:00 7.8 0.4 8.8 6.8 7.8 0.4 8.8 6.5 35 2 36 305 5.2 0 5.6 4.9 10/07/2005 17:10:00 7.6 0.4 8.4 6.5 7.7 0.4 8.8 6.5 35 2 38 305 5.2 0 5.6 4.9 10/07/2005 17:20:00 7.2 0.4 8.4 5.7 7.4 0.5 8.4 6.1 38 2 39 305 5.2 0 5.6 4.9 10/07/2005 17:30:00 6.7 0.4 7.6 5.7 6.9 0.4 8 5.7 41 4 46 305 5.2 0.1 5.6 4.9 10/07/2005 17:40:00 7 0.4 8 5.7 7.2 0.5 8 5.7 42 4 46 305 5 0.1 5.4 4.9 10/07/2005 17:50:00 6.2 0.4 7.2 5.3 6.4 0.4 7.2 5.3 45 3 41 305 5.1 0.1 5.6 4.9 10/07/2005 18:00:00 6.5 0.5 7.2 4.9 6.5 0.5 7.6 4.9 45 3 47 305 5.1 0.2 5.4 4.9 10/07/2005 18:10:00 6.2 0.4 7.2 5.3 6.4 0.4 7.2 5.3 42 2 44 305 5.1 0.1 5.6 4.9 10/07/2005 18:20:00 6.2 0.4 7.2 5.3 6.5 0.4 7.2 5.7 41 2 41 305 5.2 0.1 5.6 4.9 10/07/2005 18:30:00 5.9 0.4 6.8 4.6 6.1 0.4 6.8 4.9 40 3 41 305 5.2 0.1 5.6 4.9 10/07/2005 18:40:00 5.5 0.3 6.1 4.9 5.6 0.3 6.5 4.9 42 2 39 305 5.2 0.1 5.6 4.9 10/07/2005 18:50:00 5.4 0.3 6.1 4.6 5.4 0.3 6.1 4.6 43 2 45 305 5.1 0.1 5.6 4.9 10/07/2005 19:00:00 5.2 0.3 6.5 4.6 5.2 0.3 6.1 4.6 43 3 52 305 5.2 0.1 5.6 4.9 10/07/2005 19:10:00 6.1 0.3 6.8 5.3 6.1 0.3 6.8 4.9 47 2 42 305 5.1 0.1 5.6 4.9 10/07/2005 19:20:00 6.8 0.3 7.6 6.1 6.8 0.4 7.6 5.3 44 2 48 305 5.2 0.1 5.6 4.9 10/07/2005 19:30:00 6.9 0.3 7.6 6.1 6.9 0.4 8 6.1 43 2 40 305 5.2 0.1 5.6 4.9 10/07/2005 19:40:00 6.8 0.3 7.6 6.1 6.8 0.3 7.6 5.7 42 2 42 305 5.2 0.1 5.6 4.9 10/07/2005 19:50:00 6.6 0.4 7.6 5.3 6.5 0.5 7.6 4.9 46 4 44 305 5.2 0.1 5.6 4.9 10/07/2005 20:00:00 6.3 0.3 6.8 5.7 6.2 0.3 7.2 5.3 49 2 55 305 5.2 0.1 5.6 4.9 10/07/2005 20:10:00 6.1 0.3 6.8 4.9 6 0.3 6.8 4.9 49 2 50 305 5.2 0.1 5.6 4.9 10/07/2005 20:20:00 6.6 0.9 9.1 4.9 6.5 1 9.1 4.9 52 6 62 305 5.1 0.1 5.6 4.9 10/07/2005 20:30:00 7.3 0.7 9.1 5.3 7.3 0.8 9.1 5.3 61 4 60 305 4.7 0.1 5.4 4.4 10/07/2005 20:40:00 5.9 0.6 7.2 4.6 5.8 0.6 7.2 4.2 54 3 54 305 4.8 0.1 5.4 4.7 10/07/2005 20:50:00 5.7 0.4 6.8 4.6 5.7 0.5 6.8 4.6 56 5 50 305 4.8 0.1 5.4 4.7 10/07/2005 21:00:00 6.5 0.7 9.5 4.9 6.4 0.8 9.1 4.6 58 5 58 305 5 0.2 5.4 4.7 10/07/2005 21:10:00 8.1 0.5 9.5 6.8 8.2 0.6 9.5 6.1 48 5 44 305 4.9 0.1 5.4 4.7 10/07/2005 21:20:00 7.2 0.5 8 5.7 7.1 0.5 8.4 5.7 47 3 47 305 4.8 0 5.4 4.7 10/07/2005 21:30:00 6.7 0.5 8 5.3 6.7 0.5 8.4 5.3 45 3 44 305 4.9 0.1 5.4 4.7 10/07/2005 21:40:00 6.8 0.5 8 5.3 6.8 0.5 8 5.3 44 3 46 305 5 0.2 5.4 4.7 10/07/2005 21:50:00 6.9 0.4 8 5.7 6.7 0.5 8 5.7 42 3 42 305 5 0.1 5.4 4.7 10/07/2005 22:00:00 6.2 0.4 7.2 4.9 6.2 0.5 7.2 4.9 41 3 40 305 5 0.1 5.4 4.9 10/07/2005 22:10:00 6.5 0.4 7.2 5.3 6.5 0.4 7.2 5.3 42 3 41 305 5.1 0.1 5.6 4.9 10/07/2005 22:20:00 7.5 0.5 9.1 6.1 7.5 0.6 8.8 6.1 48 5 50 305 5.2 0.1 5.6 4.9 10/07/2005 22:30:00 7.3 0.4 8.4 6.5 7.2 0.5 8 6.1 54 3 59 305 5.2 0.1 5.6 4.9 10/07/2005 22:40:00 7.5 0.4 8.4 6.5 7.5 0.4 8.4 6.5 51 3 50 305 5.2 0.1 5.6 4.9 10/07/2005 22:50:00 7.3 0.4 8.4 6.1 7.2 0.4 8.4 6.1 51 3 46 305 5.2 0.1 5.6 4.9 10/07/2005 23:00:00 7.4 0.4 8.4 6.1 7.2 0.4 8.8 6.5 53 2 53 305 5.2 0.1 5.6 4.9 10/07/2005 23:10:00 7.3 0.4 8.4 6.1 7.1 0.4 8.4 6.1 49 3 48 305 5.3 0.1 5.6 4.9 10/07/2005 23:20:00 7.4 0.4 8.4 5.7 7.3 0.4 8.4 5.7 46 3 49 305 5.3 0.2 5.6 5.2 10/07/2005 23:30:00 9 1 10.7 6.8 8.9 1 10.7 6.8 51 4 55 305 5.2 0.2 5.6 4.9 10/07/2005 23:40:00 7.8 1 10.3 6.5 7.8 1 9.5 5.7 53 4 50 305 4.9 0.1 5.4 4.7 10/07/2005 23:50:00 6.5 0.4 7.2 5.3 6.5 0.5 7.6 5.3 43 3 46 305 4.9 0.1 5.4 4.7 10/08/2005 00:00:00 6.5 0.4 7.6 5.7 6.6 0.4 8 5.7 37 3 37 305 5 0.1 5.4 4.9 10/08/2005 00:10:00 7.7 0.5 9.1 6.5 7.7 0.5 8.8 6.5 36 3 35 305 5.2 0.1 5.6 4.9 10/08/2005 00:20:00 8.2 0.6 9.9 6.8 8.2 0.5 9.9 6.8 38 4 37 305 5.3 0.1 5.6 4.9 10/08/2005 00:30:00 7.7 0.5 9.1 6.5 7.7 0.5 9.5 6.1 39 3 40 305 5.2 0.1 5.6 4.9 10/08/2005 00:40:00 7.5 0.4 8.4 6.5 7.5 0.4 8.8 6.5 39 3 40 305 5.2 0.1 5.6 4.9 10/08/2005 00:50:00 7.5 0.4 8.8 6.5 7.5 0.4 8.8 6.1 35 3 36 305 5.2 0.1 5.6 4.9 10/08/2005 01:00:00 8.1 0.4 9.5 6.5 8 0.4 9.5 6.8 34 2 35 305 5.2 0.1 5.6 5.2 10/08/2005 01:10:00 7.6 0.4 8.4 6.5 7.6 0.4 8.8 6.1 37 2 35 305 5.3 0.1 5.9 5.2 10/08/2005 01:20:00 7 0.3 8 6.1 7 0.3 8 6.1 37 3 43 305 5.3 0.1 5.6 5.2 10/08/2005 01:30:00 7.1 0.4 8.4 6.1 7.1 0.4 8 6.1 42 3 44 305 5.2 0.1 5.6 5.2 10/08/2005 01:40:00 6.5 0.4 7.6 5.3 6.5 0.4 7.6 5.7 42 2 44 305 5.2 0.1 5.6 4.9 10/08/2005 01:50:00 6.5 0.5 8 5.3 6.3 0.5 7.6 4.9 45 3 45 305 5.3 0.1 5.6 5.2 10/08/2005 02:00:00 7 0.4 8 5.7 6.9 0.4 8 5.7 44 3 43 305 5.3 0.1 5.9 5.2 10/08/2005 02:10:00 6.8 0.4 8 5.7 6.8 0.4 7.6 5.3 44 2 47 305 5.3 0.1 5.9 5.2 10/08/2005 02:20:00 6.8 0.5 7.6 5.7 6.7 0.5 8 5.3 45 3 44 305 5.3 0 5.9 5.2 10/08/2005 02:30:00 7.6 0.4 8.4 6.8 7.4 0.4 8.8 6.5 43 3 40 305 5.4 0.1 5.9 5.2 10/08/2005 02:40:00 7.3 0.4 8.4 6.5 7.1 0.4 8.4 6.1 41 2 40 305 5.4 0 5.9 5.2 10/08/2005 02:50:00 7.3 0.4 8.4 6.5 7.3 0.4 8.4 6.5 40 2 41 305 5.4 0 5.9 5.2 10/08/2005 03:00:00 7.3 0.4 8.4 6.5 7.2 0.4 8.4 6.1 39 2 37 305 5.3 0 5.9 5.2 10/08/2005 03:10:00 7.6 0.3 8.4 6.8 7.6 0.4 8.4 6.8 39 2 36 305 5.3 0 5.9 5.2 10/08/2005 03:20:00 7.5 0.4 8.8 6.5 7.5 0.4 8.8 6.5 41 2 40 305 5.3 0 5.6 4.9 10/08/2005 03:30:00 7.3 0.5 8.8 6.1 7.3 0.4 8.4 6.1 43 3 43 305 5.2 0.1 5.6 4.9 10/08/2005 03:40:00 7.1 0.3 8 6.1 7 0.4 8 6.1 41 4 45 305 5.2 0.1 5.6 4.9 10/08/2005 03:50:00 7.2 0.4 8 6.1 7.2 0.5 8.4 5.7 39 3 39 305 5.3 0.1 5.9 5.2 10/08/2005 04:00:00 5.7 0.7 7.2 4.6 5.9 0.8 7.6 4.6 40 4 37 305 5.5 0.1 5.9 5.2 10/08/2005 04:10:00 4.4 0.5 5.3 3.4 4.4 0.4 5.3 3.4 48 8 36 305 5.2 0.1 5.9 4.9 10/08/2005 04:20:00 5.5 0.9 7.6 3.8 5.5 0.8 7.6 4.2 48 7 33 305 5.3 0 5.9 4.9 10/08/2005 04:30:00 7.2 0.4 8 6.5 7.1 0.4 8 6.1 31 2 34 305 5.5 0.1 5.9 5.4 10/08/2005 04:40:00 6.7 0.3 7.6 6.1 6.7 0.3 7.6 6.1 33 1 33 305 5.4 0 5.9 5.2 10/08/2005 04:50:00 6.2 0.3 6.8 5.3 6.3 0.4 7.2 5.3 36 1 35 305 5.3 0.1 5.9 5.2 10/08/2005 05:00:00 5 0.4 6.1 3.8 5.2 0.4 6.5 4.2 49 6 37 305 5.2 0.2 5.9 4.9 10/08/2005 05:10:00 5.5 0.8 8 4.2 5.5 0.7 8 4.2 46 6 41 305 5.4 0.2 5.9 4.9 10/08/2005 05:20:00 7.2 0.4 8.4 6.1 7.2 0.4 8 6.1 33 3 33 305 5.3 0.1 5.9 4.9 10/08/2005 05:30:00 6.8 0.4 8 5.7 6.8 0.4 8 5.7 31 3 28 305 5.4 0.1 5.9 5.2 10/08/2005 05:40:00 6.6 0.4 8 5.3 6.6 0.4 8 5.7 32 3 35 305 5.4 0.1 5.9 5.2 10/08/2005 05:50:00 6.8 0.4 7.6 5.7 6.8 0.4 8 5.7 33 3 31 305 5.4 0.1 5.9 5.2 10/08/2005 06:00:00 6.7 0.4 7.6 5.3 6.7 0.4 7.6 5.7 29 3 31 305 5.5 0.2 5.9 5.2 10/08/2005 06:10:00 7.4 0.5 8.8 6.5 7.4 0.4 8.4 6.1 29 3 31 305 5.5 0.2 5.9 5.4 10/08/2005 06:20:00 8.2 0.5 9.1 7.2 8.2 0.5 9.1 6.8 30 3 30 305 5.5 0.2 5.9 5.4 10/08/2005 06:30:00 7.7 0.5 8.8 6.1 7.7 0.5 8.8 6.1 33 3 32 305 5.5 0.2 5.9 5.4 10/08/2005 06:40:00 7.7 0.5 8.8 6.5 7.7 0.5 8.8 6.1 37 3 35 305 5.5 0.2 5.9 5.4 10/08/2005 06:50:00 7.9 0.4 9.5 6.8 7.9 0.5 9.5 6.5 37 3 38 305 5.5 0.2 5.9 5.2 10/08/2005 07:00:00 7.8 0.5 9.5 6.5 7.8 0.5 9.5 6.1 37 3 35 305 5.5 0.1 5.9 5.4 10/08/2005 07:10:00 7.5 0.4 8.4 6.5 7.4 0.4 8.4 6.1 38 3 43 305 5.5 0.1 5.9 5.4 10/08/2005 07:20:00 8 0.5 9.5 6.5 8 0.5 9.5 6.5 37 3 36 305 5.5 0.1 5.9 5.2 10/08/2005 07:30:00 8.4 0.4 9.5 7.6 8.3 0.5 9.5 7.2 36 3 38 305 5.5 0.1 5.9 5.4 10/08/2005 07:40:00 8.4 0.4 9.1 7.6 8.3 0.4 9.1 6.8 33 3 32 305 5.5 0 5.9 5.4 10/08/2005 07:50:00 8.3 0.4 9.1 7.2 8.2 0.4 9.1 7.2 35 3 31 305 5.5 0.1 5.9 5.4 10/08/2005 08:00:00 8.2 0.4 9.1 6.8 8 0.4 9.1 6.8 38 3 40 305 5.4 0 5.9 5.4 10/08/2005 08:10:00 7.9 0.5 9.1 6.8 7.8 0.5 8.8 6.8 34 2 30 305 5.4 0 5.9 5.4 10/08/2005 08:20:00 7.5 0.4 8.4 6.5 7.4 0.4 8.4 6.1 28 3 30 305 5.4 0 5.9 5.4 10/08/2005 08:30:00 7.9 0.4 8.8 6.5 7.8 0.5 9.1 6.5 27 3 33 305 5.4 0 5.9 5.4 10/08/2005 08:40:00 7.7 0.4 8.8 6.5 7.6 0.5 8.8 6.1 27 3 31 305 5.4 0 5.9 5.4 10/08/2005 08:50:00 7.4 0.5 8.8 6.1 7.4 0.5 8.4 6.1 31 3 30 305 5.4 0 5.9 5.2 10/08/2005 09:00:00 7 0.5 8.4 6.1 7 0.5 8.4 6.1 35 3 33 305 5.4 0 5.9 5.2 10/08/2005 09:10:00 7 0.4 8 5.7 7 0.4 8 5.7 33 4 33 305 5.3 0 5.9 5.2 10/08/2005 09:20:00 7.6 0.4 8.4 6.5 7.6 0.4 8.4 6.5 32 3 26 305 5.4 0 5.9 5.2 10/08/2005 09:30:00 8.1 0.4 9.1 6.8 8 0.4 9.1 6.8 34 3 33 305 5.4 0 5.9 5.4 10/08/2005 09:40:00 7.9 0.6 9.1 6.5 7.9 0.5 9.1 6.5 27 5 27 305 5.5 0.1 5.9 5.4 10/08/2005 09:50:00 7.8 0.6 9.1 6.1 7.8 0.6 9.1 6.1 15 4 16 305 5.4 0 5.9 5.4 10/08/2005 10:00:00 7.8 0.5 9.1 6.5 7.8 0.5 8.8 6.5 23 3 23 305 5.4 0 5.9 5.4 10/08/2005 10:10:00 8 0.5 9.5 6.8 8 0.5 9.5 6.8 27 3 25 305 5.4 0 5.9 5.4 10/08/2005 10:20:00 7.9 0.5 9.5 6.5 7.9 0.5 9.5 6.8 28 3 27 305 5.4 0 5.9 5.4 10/08/2005 10:30:00 7.8 0.6 9.5 6.1 7.9 0.6 9.1 6.1 24 3 22 305 5.4 0 5.9 5.2 10/08/2005 10:40:00 7.5 0.5 8.8 5.7 7.6 0.5 8.8 6.1 18 4 20 305 5.4 0 5.9 5.4 10/08/2005 10:50:00 6.8 0.5 8 5.3 6.9 0.5 8.4 5.7 9 3 7 305 5.3 0 5.9 5.2 10/08/2005 11:00:00 7.6 0.6 8.8 6.1 7.7 0.7 9.1 5.3 9 4 5 305 5.2 0 5.6 4.9 10/08/2005 11:10:00 7.7 0.5 9.1 6.1 7.7 0.5 9.1 6.1 10 3 1 305 5.2 0 5.6 4.9 10/08/2005 11:20:00 7.6 0.5 8.8 6.5 7.7 0.5 8.8 6.1 11 3 13 305 5.2 0 5.6 5.2 10/08/2005 11:30:00 7.3 0.6 8.8 5.7 7.4 0.6 8.8 5.7 9 3 12 305 5.2 0 5.6 5.2 10/08/2005 11:40:00 7.8 0.5 9.1 6.1 7.9 0.5 9.1 6.1 9 3 8 305 5.2 0 5.6 4.9 10/08/2005 11:50:00 7.3 0.5 8.8 5.7 7.5 0.6 8.8 6.1 9 3 6 305 5.2 0 5.6 4.9 10/08/2005 12:00:00 7.1 0.5 8.4 5.7 7.3 0.5 8.4 6.1 8 3 5 305 5.2 0 5.6 4.9 10/08/2005 12:10:00 7.1 0.4 8 5.3 7.2 0.4 8 5.7 7 3 5 305 5.2 0 5.6 4.9 10/08/2005 12:20:00 8.1 0.6 9.9 6.1 8.1 0.6 9.5 6.1 16 3 13 305 5.3 0 5.6 5.2 10/08/2005 12:30:00 8.7 0.6 10.3 6.8 8.7 0.6 10.3 7.2 16 3 18 305 5.4 0 5.9 5.2 10/08/2005 12:40:00 8.9 0.5 9.9 7.6 8.9 0.6 10.7 7.2 15 3 13 305 5.4 0 5.9 5.2 10/08/2005 12:50:00 9.1 0.6 10.3 7.6 9.1 0.5 10.7 7.6 15 3 16 305 5.3 0 5.6 5.2 10/08/2005 13:00:00 8.4 0.7 9.9 6.5 8.5 0.7 10.3 6.8 15 3 13 305 5.3 0 5.6 5.2 10/08/2005 13:10:00 8.5 0.7 10.7 7.2 8.5 0.7 10.7 6.5 17 3 20 305 5.3 0 5.6 5.2 10/08/2005 13:20:00 9 0.6 10.7 7.2 9 0.6 10.7 7.2 16 3 16 305 5.3 0 5.6 5.2 10/08/2005 13:30:00 8.8 0.5 9.9 7.6 8.8 0.5 10.3 7.6 15 3 12 305 5.3 0 5.6 5.2 10/08/2005 13:40:00 8.6 0.6 9.9 7.2 8.6 0.6 9.9 7.2 20 4 19 305 5.3 0 5.6 5.2 10/08/2005 13:50:00 9 0.9 10.7 7.2 8.9 0.8 10.7 6.8 24 4 25 305 5.3 0 5.9 5.2 10/08/2005 14:00:00 8.3 0.6 9.9 6.8 8.3 0.6 10.3 6.8 22 5 26 305 5.3 0 5.6 5.2 10/08/2005 14:10:00 8.4 0.7 9.9 6.8 8.4 0.7 10.3 6.8 25 4 22 305 5.3 0 5.6 4.9 10/08/2005 14:20:00 9.1 0.5 10.3 8 8.9 0.5 10.7 7.6 28 3 28 305 5.3 0 5.6 5.2 10/08/2005 14:30:00 9 0.5 10.7 7.6 8.9 0.5 10.3 7.2 28 3 32 305 5.5 0.1 5.9 5.4 10/08/2005 14:40:00 9.7 0.9 11.5 7.6 9.5 0.9 11.5 7.6 27 3 29 305 5.6 0.1 6.1 5.4 10/08/2005 14:50:00 9.7 0.5 11.1 8.4 9.5 0.5 11.1 8 28 4 30 305 5.8 0 6.1 5.6 10/08/2005 15:00:00 9.4 0.6 10.7 7.2 9.3 0.6 11.1 7.6 27 3 31 305 5.8 0 5.9 5.6 10/08/2005 15:10:00 9.2 0.5 10.3 7.6 9 0.6 10.7 7.2 27 3 21 305 5.8 0 5.9 5.6 10/08/2005 15:20:00 9.9 0.5 11.1 8.8 9.6 0.6 11.1 8.4 29 3 31 305 5.7 0 5.9 5.6 10/08/2005 15:30:00 9.5 0.5 10.7 8.4 9.3 0.5 10.7 7.2 28 3 29 305 5.9 0 5.9 5.6 10/08/2005 15:40:00 8.8 0.5 10.3 7.6 8.6 0.5 9.9 7.6 28 4 37 305 5.8 0 5.9 5.6 10/08/2005 15:50:00 9.3 0.6 10.7 8 9.2 0.6 10.7 7.6 27 4 27 305 5.9 0 5.9 5.6 10/08/2005 16:00:00 8.9 0.6 10.3 6.8 8.8 0.6 10.3 7.2 24 3 20 305 5.8 0 5.9 5.6 10/08/2005 16:10:00 8.3 0.7 9.9 6.5 8.3 0.8 9.9 6.5 22 3 18 305 5.5 0.1 5.9 5.4 10/08/2005 16:20:00 8.1 0.6 9.5 6.5 8 0.6 9.5 6.8 27 4 21 305 5.4 0 5.6 5.4 10/08/2005 16:30:00 8.7 0.6 9.9 7.2 8.6 0.6 9.9 7.2 32 3 26 305 5.5 0 5.6 5.4 10/08/2005 16:40:00 9.1 0.6 10.7 7.6 9 0.6 10.3 7.6 33 3 36 305 5.4 0 5.6 5.4 10/08/2005 16:50:00 8.8 0.5 9.9 7.6 8.8 0.5 10.3 7.2 34 3 36 305 5.5 0 5.6 5.4 10/08/2005 17:00:00 9.2 0.6 10.7 7.6 9 0.6 10.7 6.8 34 3 33 305 5.5 0 5.6 5.4 10/08/2005 17:10:00 9 0.8 10.7 6.8 8.8 0.7 10.7 6.8 35 3 37 305 5.3 0 5.6 5.4 10/08/2005 17:20:00 7.4 0.4 8.4 6.5 7.2 0.4 8.4 6.1 36 3 33 305 5.3 0 5.6 5.2 10/08/2005 17:30:00 7.2 0.4 8.4 6.1 7.1 0.5 8.4 5.7 36 3 37 305 5.3 0 5.6 5.2 10/08/2005 17:40:00 7.1 0.4 8 5.7 7.2 0.4 8.4 6.1 34 2 32 305 5.4 0 5.6 5.2 10/08/2005 17:50:00 7.7 0.5 9.1 6.8 7.7 0.4 9.1 6.8 33 2 33 305 5.4 0 5.6 5.4 10/08/2005 18:00:00 8 0.3 9.1 7.2 7.8 0.4 8.8 6.8 32 2 34 305 5.4 0 5.6 5.4 10/08/2005 18:10:00 8.5 0.5 9.5 7.2 8.4 0.5 9.5 7.2 35 3 31 305 5.4 0 5.6 5.2 10/08/2005 18:20:00 8.6 0.5 9.9 7.6 8.5 0.4 9.5 7.6 34 3 32 305 5.2 0 5.4 4.9 10/08/2005 18:30:00 9.3 0.4 10.7 8 9.1 0.5 10.7 7.6 31 3 33 305 5.1 0 5.4 4.9 10/08/2005 18:40:00 9.7 0.5 11.1 8.8 9.5 0.5 10.7 8 32 3 29 305 5.1 0 5.4 4.9 10/08/2005 18:50:00 10.3 0.6 11.8 8.8 10.1 0.6 11.8 8.4 33 3 33 305 5 0.1 5.4 4.9 10/08/2005 19:00:00 10.2 0.6 11.8 8.4 10 0.6 11.5 8.4 34 3 33 305 5 0.1 5.4 4.9 10/08/2005 19:10:00 10.9 0.7 12.2 9.1 10.8 0.7 12.6 8.4 33 3 32 305 5 0.1 5.4 4.9 10/08/2005 19:20:00 11 0.6 12.6 9.1 10.8 0.7 12.6 8.8 33 4 26 305 5 0.1 5.4 4.9 10/08/2005 19:30:00 12 0.6 13 9.9 11.8 0.7 13 9.5 34 3 34 305 5 0.1 5.4 4.9 10/08/2005 19:40:00 11.3 0.7 12.6 9.5 11.1 0.7 12.6 9.5 37 3 36 305 5 0.1 5.4 4.9 10/08/2005 19:50:00 11.2 0.6 12.6 9.1 11 0.7 12.6 9.1 38 3 36 305 5 0.1 5.4 4.9 10/08/2005 20:00:00 11 0.7 12.6 8.8 10.8 0.8 12.6 8.8 39 3 39 305 4.9 0.1 5.4 4.9 10/08/2005 20:10:00 10.4 0.7 12.2 8.8 10.3 0.7 12.2 8.8 37 3 39 305 5 0.2 5.4 4.9 10/08/2005 20:20:00 10.9 0.6 12.6 9.5 10.8 0.7 12.6 8.8 35 3 38 305 5 0.2 5.4 4.9 10/08/2005 20:30:00 10.7 1 12.2 8.4 10.6 0.9 12.6 8.4 35 3 34 305 5 0.2 5.6 4.9 10/08/2005 20:40:00 10.3 0.6 11.8 8.8 10.2 0.6 11.8 8 37 3 36 305 5 0.1 5.4 4.9 10/08/2005 20:50:00 10.2 0.5 11.5 8.8 10.1 0.6 11.8 8.4 40 3 39 305 5 0.2 5.4 4.9 10/08/2005 21:00:00 10.2 0.7 11.8 8.4 10.2 0.7 11.8 8.4 38 3 44 305 5 0.2 5.4 4.9 10/08/2005 21:10:00 10.9 0.7 12.2 9.1 10.7 0.7 12.2 8.4 39 3 34 305 4.9 0.1 5.4 4.9 10/08/2005 21:20:00 11 0.7 12.6 9.1 10.8 0.8 12.6 8.8 38 3 38 305 4.9 0.1 5.4 4.9 10/08/2005 21:30:00 10.3 0.7 11.8 8 10.2 0.7 11.8 8 37 4 41 305 4.9 0.1 5.4 4.9 10/08/2005 21:40:00 9.6 0.7 11.1 8 9.4 0.7 11.1 7.6 36 4 32 305 4.9 0.1 5.4 4.7 10/08/2005 21:50:00 10.1 0.6 11.5 8.4 10 0.6 11.5 8 34 4 27 305 4.9 0.1 5.4 4.7 10/08/2005 22:00:00 9.4 0.6 11.5 8 9.3 0.6 11.1 7.6 36 4 31 305 4.9 0.1 5.4 4.7 10/08/2005 22:10:00 9 0.7 10.7 7.6 9 0.7 10.7 7.2 34 3 36 305 4.9 0.1 5.4 4.7 10/08/2005 22:20:00 9.4 0.7 11.1 7.6 9.3 0.8 11.5 7.6 34 3 33 305 4.9 0.1 5.4 4.7 10/08/2005 22:30:00 9.8 0.7 11.1 7.6 9.7 0.8 11.5 7.6 36 3 35 305 4.9 0.1 5.4 4.7 10/08/2005 22:40:00 9 0.7 10.7 7.2 8.8 0.7 10.3 7.2 35 3 34 305 4.8 0 5.4 4.7 10/08/2005 22:50:00 9 0.6 10.3 7.2 8.9 0.6 9.9 7.2 34 3 33 305 4.8 0 5.4 4.7 10/08/2005 23:00:00 8.5 0.7 10.3 6.8 8.5 0.7 10.3 6.8 33 3 28 305 4.8 0 5.4 4.7 10/08/2005 23:10:00 9 0.5 10.3 7.6 9 0.5 9.9 7.2 34 3 35 305 4.8 0.1 5.4 4.7 10/08/2005 23:20:00 8.9 0.5 10.3 7.2 8.9 0.5 10.7 7.6 30 3 29 305 4.8 0 5.4 4.7 10/08/2005 23:30:00 9.5 0.5 10.7 8.4 9.4 0.6 10.7 8 29 3 31 305 4.8 0.1 5.4 4.7 10/08/2005 23:40:00 9.7 0.4 11.1 8.4 9.7 0.5 10.7 8.4 26 2 27 305 4.8 0 5.4 4.7 10/08/2005 23:50:00 9.7 0.4 10.7 8.8 9.6 0.4 11.1 8.4 28 2 31 305 4.8 0 5.4 4.7 10/09/2005 00:00:00 9.9 0.5 11.1 8.4 9.9 0.6 11.1 8.4 27 2 27 305 4.8 0 5.4 4.7 10/09/2005 00:10:00 9.2 0.6 10.7 7.6 9.1 0.6 10.7 7.6 28 2 30 305 4.7 0 5.4 4.7 10/09/2005 00:20:00 8.7 0.5 9.9 7.6 8.7 0.5 9.9 7.2 29 3 30 305 4.7 0.1 4.9 4.4 10/09/2005 00:30:00 8.6 0.5 9.5 7.2 8.6 0.5 9.9 7.2 25 2 26 305 4.7 0.1 4.9 4.4 10/09/2005 00:40:00 8.7 0.5 10.3 7.2 8.7 0.5 9.9 7.2 26 3 27 305 4.7 0.1 5.2 4.4 10/09/2005 00:50:00 8.5 0.5 9.9 7.2 8.6 0.5 9.9 7.2 27 3 24 305 4.7 0.1 5.2 4.4 10/09/2005 01:00:00 9.2 0.5 10.3 8 9.1 0.5 10.3 7.6 26 2 29 305 4.7 0.1 4.9 4.4 10/09/2005 01:10:00 9.6 0.6 11.1 8.4 9.5 0.6 11.1 8 30 3 32 305 4.8 0 5.2 4.4 10/09/2005 01:20:00 9.3 0.6 10.7 8 9 0.6 10.7 7.6 33 3 36 305 4.7 0.1 5.2 4.4 10/09/2005 01:30:00 9.5 0.5 11.1 8 9.4 0.6 10.7 8 29 3 33 305 4.8 0 5.4 4.7 10/09/2005 01:40:00 9.4 0.5 11.1 8 9.2 0.5 11.1 8 30 3 28 305 4.7 0 5.2 4.7 10/09/2005 01:50:00 9.9 0.6 11.5 8 9.8 0.7 11.5 8 32 3 32 305 4.7 0 5.2 4.4 10/09/2005 02:00:00 10.4 0.5 11.8 8.8 10.3 0.6 11.5 8.4 34 3 33 305 4.8 0 5.2 4.7 10/09/2005 02:10:00 10.3 0.5 11.5 8.8 10.1 0.5 11.5 8.8 34 2 36 305 4.8 0 5.4 4.7 10/09/2005 02:20:00 9.9 0.6 11.5 8.8 9.7 0.6 11.5 8.4 34 3 35 305 4.7 0.1 5.2 4.4 10/09/2005 02:30:00 10.1 0.5 11.1 8.4 9.9 0.5 11.1 8 33 3 35 305 4.7 0 4.9 4.4 10/09/2005 02:40:00 10.1 0.6 11.5 8.4 9.9 0.6 11.1 8.4 31 2 29 305 4.6 0.1 4.9 4.4 10/09/2005 02:50:00 9.9 0.4 11.1 8.8 9.7 0.4 11.5 8.8 31 2 27 305 4.6 0.1 4.9 4.4 10/09/2005 03:00:00 9.2 0.5 10.3 8 9.1 0.5 10.7 7.6 29 3 30 305 4.5 0.1 4.9 4.4 10/09/2005 03:10:00 9.5 0.6 11.5 8 9.3 0.6 11.5 7.6 30 2 26 305 4.5 0.1 4.9 4.4 10/09/2005 03:20:00 9.2 0.5 10.7 7.6 9 0.5 10.3 7.2 30 3 33 305 4.5 0.1 4.9 4.4 10/09/2005 03:30:00 9.6 0.5 10.7 8 9.4 0.4 10.7 8.4 27 3 29 305 4.5 0.1 4.9 4.4 10/09/2005 03:40:00 9.9 0.4 11.1 8.8 9.7 0.5 11.5 8 27 2 27 305 4.4 0.1 4.9 4.2 10/09/2005 03:50:00 9.3 0.7 11.1 7.6 9.1 0.7 11.1 7.2 28 3 22 305 4.4 0.1 4.9 4.4 10/09/2005 04:00:00 10.1 0.5 11.1 8.8 9.9 0.5 11.5 8.4 28 2 26 305 4.5 0.1 4.9 4.4 10/09/2005 04:10:00 9.6 0.5 10.7 8.4 9.5 0.5 10.7 8.4 28 2 26 305 4.5 0.1 4.9 4.4 10/09/2005 04:20:00 9.3 0.5 11.1 7.6 9.3 0.5 10.7 8 28 3 31 305 4.5 0.1 4.9 4.4 10/09/2005 04:30:00 9 0.5 10.3 7.2 9 0.5 9.9 7.2 28 3 26 305 4.5 0.1 4.9 4.4 10/09/2005 04:40:00 9.7 0.5 11.1 8.4 9.6 0.5 11.1 8 31 3 29 305 4.5 0.1 4.9 4.4 10/09/2005 04:50:00 10 0.5 11.5 8.4 9.9 0.6 11.5 8.8 29 3 30 305 4.5 0.1 4.9 4.4 10/09/2005 05:00:00 10 0.5 11.1 8.4 9.8 0.6 11.1 8 32 3 33 305 4.4 0.1 4.9 4.4 10/09/2005 05:10:00 9.9 0.6 11.1 8.4 9.8 0.6 11.5 8 31 3 32 305 4.4 0.1 4.9 4.4 10/09/2005 05:20:00 9.5 0.5 10.7 8.4 9.5 0.5 11.1 8.4 25 3 25 305 4.4 0.1 4.9 4.4 10/09/2005 05:30:00 9.8 0.7 11.1 8.4 9.8 0.7 11.5 8 24 3 24 305 4.3 0 4.7 4.2 10/09/2005 05:40:00 10.2 0.6 11.5 8.8 10.3 0.6 11.8 8.8 25 3 22 305 4.2 0 4.7 4.2 10/09/2005 05:50:00 10.5 0.5 11.8 9.1 10.4 0.6 11.8 9.1 27 3 25 305 4.2 0 4.7 4.2 10/09/2005 06:00:00 9.7 0.5 10.7 8.4 9.7 0.5 11.1 8.4 28 3 25 305 4.2 0 4.7 4.2 10/09/2005 06:10:00 9.9 0.5 11.1 8.4 9.8 0.6 11.1 8 30 4 29 305 4.2 0.1 4.7 3.9 10/09/2005 06:20:00 10.1 0.6 11.5 8.8 10.1 0.6 11.8 8.8 31 3 33 305 4.1 0.1 4.7 3.9 10/09/2005 06:30:00 10.5 0.5 11.5 9.1 10.4 0.6 11.8 8.8 31 3 29 305 4 0 4.4 3.9 10/09/2005 06:40:00 10 0.7 11.8 8.4 9.9 0.7 11.8 7.6 34 3 37 305 4.1 0.1 4.7 3.9 10/09/2005 06:50:00 10.7 0.7 12.2 8.8 10.6 0.8 12.2 8.4 33 4 32 305 4 0.1 4.4 3.9 10/09/2005 07:00:00 10.7 0.8 12.6 8.4 10.6 0.9 12.6 8 34 4 32 305 4 0.1 4.7 3.9 10/09/2005 07:10:00 10 0.6 11.5 8.4 10 0.6 11.5 7.6 28 4 29 305 4 0.1 4.4 3.7 10/09/2005 07:20:00 9.9 0.7 11.5 8.4 10 0.7 11.8 8.4 27 3 26 305 3.9 0.1 4.4 3.7 10/09/2005 07:30:00 10.3 0.5 11.8 8.8 10.3 0.6 11.8 9.1 27 3 25 305 3.9 0.1 4.4 3.7 10/09/2005 07:40:00 10.6 0.7 11.8 8.4 10.5 0.8 12.2 8.8 28 3 27 305 3.8 0 4.4 3.7 10/09/2005 07:50:00 10.5 0.6 12.2 8.8 10.4 0.7 12.6 8.8 31 3 32 305 3.7 0 4.2 3.4 10/09/2005 08:00:00 10.2 0.5 11.5 8.8 10.2 0.6 12.2 8.8 33 4 32 305 3.7 0 4.2 3.4 10/09/2005 08:10:00 9.6 0.6 10.7 7.6 9.6 0.6 11.1 7.6 31 5 30 305 3.7 0 4.2 3.4 10/09/2005 08:20:00 9.4 0.7 11.1 7.6 9.6 0.7 11.5 7.6 26 3 30 305 3.7 0.1 4.2 3.4 10/09/2005 08:30:00 9 0.6 10.3 7.2 9.1 0.7 10.7 7.2 30 5 32 305 3.6 0.1 4.2 3.4 10/09/2005 08:40:00 9 0.6 10.3 7.2 9.1 0.6 10.7 7.2 28 4 38 305 3.6 0.1 3.9 3.4 10/09/2005 08:50:00 9 0.5 10.3 6.8 9.2 0.6 10.3 6.8 27 4 22 305 3.6 0.1 4.2 3.4 10/09/2005 09:00:00 9.2 0.6 10.3 7.2 9.3 0.7 10.7 7.6 27 4 26 305 3.7 0.1 4.2 3.4 10/09/2005 09:10:00 9.1 0.8 10.7 7.2 9.2 0.8 11.1 7.2 31 4 28 305 3.6 0.1 4.2 3.4 10/09/2005 09:20:00 8.9 0.6 10.3 7.2 9 0.6 10.7 7.2 34 6 34 305 3.5 0.2 4.2 3.2 10/09/2005 09:30:00 8.8 0.7 10.7 6.8 8.9 0.8 10.7 6.8 34 5 30 305 3.5 0.1 3.9 3.2 10/09/2005 09:40:00 8.9 0.7 10.7 6.5 9 0.7 10.7 6.5 33 6 39 305 3.4 0.2 3.9 3.2 10/09/2005 09:50:00 8.8 0.8 10.7 6.8 8.9 0.8 11.1 7.2 39 8 41 305 3.4 0.2 3.7 3.2 10/09/2005 10:00:00 9.3 0.7 11.1 7.6 9.4 0.7 11.1 7.6 37 5 37 305 3.4 0.2 3.7 3.2 10/09/2005 10:10:00 9.1 0.7 10.7 7.2 9.2 0.8 10.7 7.2 42 6 31 305 3.4 0.2 3.9 3.2 10/09/2005 10:20:00 9.2 0.6 10.3 7.2 9.2 0.7 10.7 7.2 48 6 51 305 3.5 0.2 4.2 3.2 10/09/2005 10:30:00 8.6 0.6 9.9 6.8 8.7 0.6 9.9 6.8 37 6 35 305 3.4 0.2 3.9 3.2 10/09/2005 10:40:00 8 0.6 9.5 6.5 8.1 0.6 9.9 6.5 38 6 41 305 3.4 0.2 3.9 3.2 10/09/2005 10:50:00 8.1 0.6 9.5 6.8 8.2 0.7 9.5 6.5 37 5 35 305 3.4 0.1 3.7 3.2 10/09/2005 11:00:00 8.5 0.6 10.3 6.8 8.6 0.6 10.3 6.8 28 5 30 305 3.3 0 3.7 3.2 10/09/2005 11:10:00 8.4 0.7 10.3 6.5 8.5 0.7 10.7 6.5 34 8 31 305 3.3 0 3.7 2.9 10/09/2005 11:20:00 8.4 0.7 10.3 6.8 8.6 0.7 10.3 7.2 36 6 36 305 3.1 0.1 3.4 2.9 10/09/2005 11:30:00 7.6 0.7 9.1 6.1 7.8 0.7 9.5 6.1 34 5 36 305 2.9 0.1 3.4 2.7 10/09/2005 11:40:00 7.8 0.7 9.9 6.1 8 0.8 9.9 6.1 40 5 45 305 2.8 0.1 3.2 2.5 10/09/2005 11:50:00 7.2 0.7 9.1 5.7 7.4 0.6 9.1 5.7 39 7 34 305 2.9 0.1 3.4 2.7 10/09/2005 12:00:00 7.5 0.7 9.1 6.1 7.8 0.7 9.5 6.1 23 4 23 305 2.8 0.1 3.4 2.7 10/09/2005 12:10:00 7.6 0.6 8.8 6.1 7.8 0.7 9.1 6.1 31 6 21 305 2.7 0.1 3.2 2.5 10/09/2005 12:20:00 7.1 0.6 8.8 6.1 7.3 0.6 9.1 5.7 36 8 26 305 2.6 0 3.2 2.5 10/09/2005 12:30:00 7.1 0.7 8.4 5.3 7.4 0.8 9.1 5.3 25 9 39 305 2.6 0.1 3.2 2.5 10/09/2005 12:40:00 6.2 0.6 8 4.9 6.5 0.6 8.4 4.9 36 6 24 305 2.5 0.1 3.2 2.2 10/09/2005 12:50:00 6.5 0.6 8 4.9 6.8 0.6 8.8 4.9 20 6 17 305 2.7 0.1 3.2 2.5 10/09/2005 13:00:00 6.7 0.7 8.8 5.3 7 0.8 8.8 5.3 23 5 22 305 2.7 0.1 3.2 2.5 10/09/2005 13:10:00 6.5 0.7 8 4.9 6.8 0.8 8.4 4.9 19 6 10 305 2.8 0.2 3.2 2.5 10/09/2005 13:20:00 6.8 0.5 8 5.7 7.1 0.5 8.4 5.7 20 7 13 305 2.8 0.2 3.2 2.5 10/09/2005 13:30:00 6.9 0.5 8.4 5.3 7.2 0.5 8.4 5.7 24 5 19 305 2.8 0.2 3.2 2.7 10/09/2005 13:40:00 7.2 0.6 8.4 5.7 7.4 0.6 8.8 5.7 22 7 16 305 2.8 0.1 3.2 2.5 10/09/2005 13:50:00 6.9 0.6 8.4 5.7 7 0.6 8.4 5.3 28 5 30 305 2.8 0.2 3.4 2.5 10/09/2005 14:00:00 6.9 0.5 8 5.3 7.1 0.6 8.8 5.3 20 6 38 305 2.8 0.2 3.4 2.7 10/09/2005 14:10:00 6.7 0.7 8.8 4.9 7.1 0.7 9.1 5.3 19 5 10 305 2.7 0.1 3.2 2.5 10/09/2005 14:20:00 6.6 0.5 7.6 5.3 6.9 0.6 8.4 5.3 14 5 12 305 2.6 0.1 3.2 2.5 10/09/2005 14:30:00 6.2 0.5 7.2 4.9 6.5 0.5 8 4.9 21 5 18 305 2.7 0.1 3.2 2.5 10/09/2005 14:40:00 6.2 0.6 7.6 4.6 6.5 0.7 8 4.9 14 4 13 305 2.7 0.1 3.2 2.5 10/09/2005 14:50:00 6.5 0.6 8 5.3 6.8 0.5 8 4.9 13 4 5 305 2.6 0.1 3.2 2.2 10/09/2005 15:00:00 5.9 0.7 7.2 4.2 6.2 0.7 8 4.9 14 5 3 305 2.5 0.1 2.9 2.2 10/09/2005 15:10:00 6.2 0.5 7.6 4.9 6.5 0.6 8.4 4.9 10 4 10 305 2.7 0.1 3.2 2.5 10/09/2005 15:20:00 6.7 0.6 8 5.3 7.1 0.6 8.8 5.7 6 5 358 305 2.7 0.1 3.2 2.5 10/09/2005 15:30:00 6.9 0.4 7.6 5.7 7.3 0.4 8.4 6.1 4 4 10 305 2.6 0 3.2 2.5 10/09/2005 15:40:00 6.3 0.5 7.2 4.9 6.6 0.6 8 4.9 4 3 2 305 2.8 0.2 3.4 2.5 10/09/2005 15:50:00 6.3 0.5 7.2 5.3 6.6 0.5 7.6 5.3 13 5 21 305 2.9 0.1 3.4 2.7 10/09/2005 16:00:00 7 0.5 8 5.3 7.3 0.5 8.4 5.7 13 3 12 305 2.8 0.1 3.2 2.7 10/09/2005 16:10:00 6.2 0.5 7.2 4.9 6.6 0.5 8 5.3 17 3 12 305 2.8 0.1 3.2 2.5 10/09/2005 16:20:00 7.2 0.8 8.8 4.9 7.5 0.9 9.1 5.3 5 7 7 305 2.8 0.1 3.2 2.7 10/09/2005 16:30:00 6.5 0.7 8 4.6 6.7 0.8 8.4 4.6 3 5 1 305 2.8 0.1 3.2 2.5 10/09/2005 16:40:00 6.5 0.6 8 5.3 6.9 0.6 8.4 4.9 9 4 4 305 2.8 0.1 3.2 2.7 10/09/2005 16:50:00 7.2 0.8 8.8 5.3 7.6 0.8 9.1 5.3 4 4 4 305 2.7 0.1 3.2 2.5 10/09/2005 17:00:00 7.5 0.8 9.1 6.1 7.9 0.7 9.1 5.7 10 5 6 305 2.6 0 3.2 2.5 10/09/2005 17:10:00 7.1 0.7 8.4 4.9 7.5 0.7 9.1 4.9 12 4 11 305 2.5 0 2.9 2.5 10/09/2005 17:20:00 7.5 0.5 8.8 6.1 7.8 0.5 9.1 6.1 13 6 17 305 2.5 0.1 3.2 2.5 10/09/2005 17:30:00 7.1 0.6 8.8 5.3 7.5 0.6 9.1 5.3 12 6 10 305 2.6 0 3.2 2.5 10/09/2005 17:40:00 7.7 1 10.3 5.7 7.9 1.1 10.7 5.3 12 8 10 305 2.6 0.1 3.2 2.2 10/09/2005 17:50:00 8 0.8 9.9 5.7 8.2 0.9 10.3 5.7 12 5 8 305 2.6 0.1 3.2 2.2 10/09/2005 18:00:00 7.9 0.8 9.9 6.1 8 0.9 10.3 6.1 22 8 12 305 2.5 0.1 3.2 2.2 10/09/2005 18:10:00 8.7 0.9 10.3 6.5 9 1 10.7 6.5 8 4 8 305 2.4 0.2 2.9 2.2 10/09/2005 18:20:00 8.3 0.7 9.9 6.1 8.7 0.7 10.3 6.8 6 5 3 305 2.3 0.1 2.9 2 10/09/2005 18:30:00 8.2 1 10.7 6.1 8.5 1 10.7 6.5 7 4 6 305 2 0.1 2.7 1.7 10/09/2005 18:40:00 8.9 0.9 11.5 7.2 9.2 0.9 11.8 7.6 7 5 359 305 2.2 0.1 2.7 2 10/09/2005 18:50:00 8.5 1.3 10.7 5.7 8.8 1.4 11.1 6.1 8 5 5 305 1.8 0.2 2.5 1.5 10/09/2005 19:00:00 8.5 1.3 11.1 5.3 8.6 1.2 11.1 5.3 9 6 18 305 1.9 0.2 2.5 1.5 10/09/2005 19:10:00 10.1 0.7 11.5 7.6 10.3 0.8 11.8 7.6 7 5 5 305 1.9 0.1 2.5 1.5 10/09/2005 19:20:00 9.2 0.8 11.5 7.2 9.4 0.9 11.5 7.2 11 5 6 305 1.8 0.1 2.2 1.5 10/09/2005 19:30:00 9.5 0.8 11.8 7.6 9.7 0.8 12.2 7.6 14 5 11 305 2 0 2.5 1.7 10/09/2005 19:40:00 9.6 0.8 11.5 6.8 9.9 0.8 11.8 7.6 8 4 7 305 1.9 0 2.5 1.7 10/09/2005 19:50:00 10.6 0.6 11.8 8.8 10.9 0.7 12.6 8.8 2 5 359 305 2 0.1 2.5 1.7 10/09/2005 20:00:00 10.1 0.8 11.8 8 10.4 0.9 12.2 8.4 13 3 15 305 1.9 0.1 2.2 1.7 10/09/2005 20:10:00 9 0.8 10.7 6.8 9.2 0.8 11.1 7.2 7 6 8 305 1.7 0.1 2.2 1.5 10/09/2005 20:20:00 8.1 0.8 10.3 6.5 8.3 0.7 9.9 6.5 9 11 9 305 1.4 0.1 2 1.3 10/09/2005 20:30:00 8.9 0.8 10.7 7.2 9 0.8 11.1 7.2 14 6 17 305 1.6 0.1 2.2 1.3 10/09/2005 20:40:00 8.8 0.8 10.7 6.5 9 0.8 10.7 6.8 15 6 14 305 1.7 0.1 2.2 1.5 10/09/2005 20:50:00 8.6 1.2 11.5 5.7 8.8 1.3 12.2 5.7 5 10 2 305 1.7 0.2 2.2 1.5 10/09/2005 21:00:00 8.1 1.1 11.5 6.1 8.3 1.1 11.5 6.5 6 5 5 305 1.9 0.1 2.2 1.5 10/09/2005 21:10:00 7.9 0.6 9.9 6.5 8.1 0.7 9.9 6.5 12 5 17 305 1.9 0 2.2 1.7 10/09/2005 21:20:00 8.1 0.8 9.9 6.1 8.3 0.9 10.3 6.1 17 9 22 305 1.7 0.2 2.2 1.3 10/09/2005 21:30:00 8.5 1.5 11.5 5.7 8.7 1.5 11.5 6.1 19 6 19 305 1.5 0.1 2.2 1.3 10/09/2005 21:40:00 8 0.5 9.5 6.5 8.3 0.6 9.9 6.5 15 4 22 305 1.4 0 2 1.3 10/09/2005 21:50:00 7.9 0.6 9.1 6.5 8.2 0.6 9.9 6.5 11 4 8 305 1.7 0.1 2.2 1.5 10/09/2005 22:00:00 7.5 0.6 9.1 5.7 7.9 0.7 9.1 6.1 3 10 2 305 1.8 0.1 2.2 1.5 10/09/2005 22:10:00 6.6 0.6 8 4.6 6.9 0.6 8.4 5.3 6 6 15 305 1.8 0.1 2.2 1.5 10/09/2005 22:20:00 7 0.6 8.8 5.3 7.4 0.7 9.1 5.7 18 4 17 305 1.9 0.1 2.2 1.7 10/09/2005 22:30:00 7 0.5 8.4 5.7 7.4 0.5 8.8 6.1 9 7 18 305 1.9 0 2.2 1.7 10/09/2005 22:40:00 6.8 0.9 8.8 4.6 7.1 0.9 9.1 4.9 357 7 351 305 1.9 0.1 2.2 1.7 10/09/2005 22:50:00 7.1 0.9 9.1 5.3 7.5 0.9 9.1 5.3 354 5 351 305 1.9 0 2.2 1.7 10/09/2005 23:00:00 7 0.5 8.4 5.3 7.4 0.5 8.8 5.7 354 4 358 305 1.9 0.1 2.2 1.7 10/09/2005 23:10:00 6.8 0.5 8 4.9 7.2 0.5 8.4 5.3 353 5 347 305 1.9 0.1 2.2 1.7 10/09/2005 23:20:00 6.7 0.8 8.8 4.9 7.1 0.8 8.8 4.9 353 5 352 305 1.9 0.1 2.2 1.7 10/09/2005 23:30:00 5.8 0.8 8 4.2 6.2 0.8 8.8 4.6 358 5 357 305 1.9 0.1 2.2 1.7 10/09/2005 23:40:00 7 0.7 8.8 5.3 7.3 0.7 9.1 5.3 359 5 1 305 1.9 0.1 2.2 1.5 10/09/2005 23:50:00 5.1 0.8 7.2 3.4 5.4 0.8 8 3.4 2 5 6 305 1.7 0.2 2.2 1.5 10/10/2005 00:00:00 6.6 0.6 8 4.6 6.9 0.7 8.4 4.9 3 7 7 305 1.7 0.1 2.2 1.5 10/10/2005 00:10:00 5.9 0.6 7.6 4.6 6.3 0.6 8 4.6 16 5 16 305 1.5 0 2 1.3 10/10/2005 00:20:00 4.7 0.5 6.1 3.4 5 0.6 6.5 3.4 24 11 12 305 1.6 0.1 2.2 1.5 10/10/2005 00:30:00 5.2 0.8 6.5 3.4 5.4 0.9 6.8 3.4 23 10 18 305 1.7 0.1 2.2 1.5 10/10/2005 00:40:00 5.2 0.5 6.1 4.2 5.6 0.5 6.5 4.6 24 5 21 305 1.9 0 2.5 2 10/10/2005 00:50:00 4.3 0.4 5.3 3 4.7 0.4 5.7 3.8 15 4 12 305 2.1 0 2.5 2 10/10/2005 01:00:00 6.8 1 8.4 3.4 7.2 1.1 8.8 3.8 3 6 4 305 2.3 0.1 2.7 2 10/10/2005 01:10:00 6.9 0.5 8 5.7 7.3 0.5 8.4 6.1 356 4 351 305 2.2 0.1 2.7 2 10/10/2005 01:20:00 7.4 1.1 9.1 4.9 7.8 1.2 9.5 4.9 354 5 356 305 1.7 0.3 2.7 1.3 10/10/2005 01:30:00 5.4 0.9 7.6 3.8 5.6 0.9 7.6 3.8 353 5 350 305 1.4 0.1 2.2 1.3 10/10/2005 01:40:00 8 1.2 9.9 4.2 8.2 1.3 10.3 4.9 353 6 348 305 2.2 0.3 2.9 1.5 10/10/2005 01:50:00 9.3 0.8 11.1 6.5 9.6 0.9 11.5 7.2 349 4 354 305 2.6 0 3.2 2.5 10/10/2005 02:00:00 8.9 0.7 10.7 6.8 9.3 0.8 11.1 6.1 351 3 354 305 2.5 0 2.9 2.5 10/10/2005 02:10:00 8.1 0.6 9.5 6.5 8.5 0.6 9.9 6.5 358 5 350 305 2.5 0 2.9 2.5 10/10/2005 02:20:00 8 1.3 10.3 4.9 8.3 1.2 11.1 5.3 10 3 13 305 2.3 0.2 2.9 2 10/10/2005 02:30:00 5.4 0.6 6.8 3.4 5.7 0.6 7.2 4.2 12 5 13 305 2.2 0.2 2.9 2 10/10/2005 02:40:00 7.4 1.4 11.5 4.9 7.6 1.3 11.5 5.3 18 16 6 305 2.6 0 3.2 2.5 10/10/2005 02:50:00 9.4 1.3 12.2 6.8 9.5 1.3 12.6 7.2 27 11 12 305 2.6 0.1 3.2 2.2 10/10/2005 03:00:00 12.2 0.9 13.7 9.9 12.3 1 14.1 9.1 16 3 15 305 2.8 0.1 3.2 2.7 10/10/2005 03:10:00 11.4 0.8 13.7 9.1 11.5 0.8 13.7 9.1 18 4 19 305 2.7 0 3.2 2.7 10/10/2005 03:20:00 10 0.8 12.2 8.4 10.2 0.8 12.6 8.4 22 3 19 305 2.7 0 3.2 2.5 10/10/2005 03:30:00 10.3 0.7 11.8 8.4 10.4 0.8 12.2 8 20 4 24 305 2.7 0 3.2 2.5 10/10/2005 03:40:00 11 0.6 12.6 9.9 11.1 0.6 13 9.5 16 3 13 305 2.8 0.1 3.2 2.7 10/10/2005 03:50:00 9.7 0.8 11.5 7.6 9.9 0.9 11.8 8 20 4 15 305 2.8 0.1 3.2 2.7 10/10/2005 04:00:00 10.5 0.8 12.6 8.4 10.6 0.8 13 8.8 21 5 21 305 2.9 0 3.4 2.7 10/10/2005 04:10:00 10.7 0.6 12.2 9.1 10.8 0.6 12.6 8.8 21 3 19 305 3 0 3.4 2.9 10/10/2005 04:20:00 11.1 0.7 13 9.1 11.2 0.7 13.3 8.8 19 5 18 305 3.1 0 3.7 2.9 10/10/2005 04:30:00 11.6 0.7 13.3 9.5 11.7 0.8 13.3 9.1 23 5 22 305 3.1 0.1 3.7 2.9 10/10/2005 04:40:00 11.7 0.7 13 9.5 11.7 0.8 13.3 9.1 28 3 22 305 3.1 0.1 3.4 2.9 10/10/2005 04:50:00 12 0.6 13.3 9.5 12 0.7 13.7 9.5 24 4 22 305 3 0.1 3.4 2.9 10/10/2005 05:00:00 11.5 0.9 13.7 8.8 11.6 1 13.7 8.4 26 4 27 305 3 0.1 3.4 2.9 10/10/2005 05:10:00 9.8 0.8 13.3 8 9.9 0.8 13 7.6 31 5 27 305 2.9 0.1 3.4 2.7 10/10/2005 05:20:00 10.2 0.6 11.8 8.4 10.2 0.7 11.8 8.4 33 6 36 305 2.8 0.1 3.2 2.7 10/10/2005 05:30:00 10.7 0.8 12.2 8.4 10.7 0.8 12.6 8.4 36 5 38 305 2.8 0.1 3.4 2.7 10/10/2005 05:40:00 10.6 0.7 12.2 8.8 10.7 0.8 12.2 8.4 36 3 33 305 2.8 0.1 3.4 2.7 10/10/2005 05:50:00 9.4 0.9 11.5 7.2 9.5 1 11.5 7.2 36 5 35 305 2.7 0 3.2 2.7 10/10/2005 06:00:00 10.3 0.7 11.8 8.8 10.4 0.7 12.2 8.4 28 4 28 305 2.7 0 3.2 2.7 10/10/2005 06:10:00 10.3 0.7 11.8 8.4 10.4 0.7 12.2 8.4 26 6 26 305 2.7 0.1 3.2 2.7 10/10/2005 06:20:00 10 0.9 12.6 7.6 10.1 1 12.6 7.6 34 5 35 305 2.7 0 3.2 2.5 10/10/2005 06:30:00 10.2 1 12.2 8 10.2 1 12.2 8 31 4 38 305 2.6 0 2.9 2.5 10/10/2005 06:40:00 11.5 0.9 13.7 9.1 11.5 1 14.1 9.1 29 7 33 305 2.6 0 3.2 2.5 10/10/2005 06:50:00 11 1.2 14.1 8.8 11.1 1.2 14.5 8.8 24 5 22 305 2.6 0 3.2 2.5 10/10/2005 07:00:00 10.8 1.2 13.3 8 10.9 1.2 13.3 8 25 5 19 305 2.6 0 2.9 2.5 10/10/2005 07:10:00 10.8 0.9 13.3 8.4 10.8 1 13.7 8.4 25 6 27 305 2.5 0 2.9 2.5 10/10/2005 07:20:00 11.5 1.3 14.1 8 11.6 1.2 14.1 8.4 24 4 36 305 2.6 0 2.9 2.5 10/10/2005 07:30:00 11.3 1.1 14.1 8.4 11.2 1.1 14.5 8.8 32 7 30 305 2.5 0 2.7 2.2 10/10/2005 07:40:00 11.8 1 14.1 9.1 11.8 1.1 14.1 8.4 38 4 40 305 2.3 0.1 2.7 2.2 10/10/2005 07:50:00 10.8 0.8 13 8.4 10.9 0.9 13.3 8 37 4 37 305 2.2 0.1 2.7 2.2 10/10/2005 08:00:00 10.7 1.2 15.3 8.4 10.8 1.3 15.3 8.4 24 6 36 305 2.3 0.1 2.7 2.2 10/10/2005 08:10:00 12.2 1 14.5 9.9 12.1 1 14.5 9.1 35 5 37 305 2.2 0 2.7 2 10/10/2005 08:20:00 11.3 1.5 14.5 8.4 11.3 1.4 14.9 8 23 7 21 305 2.2 0 2.5 2 10/10/2005 08:30:00 9.8 0.8 11.5 8 10 0.8 11.8 8.4 22 5 26 305 2.2 0 2.7 2 10/10/2005 08:40:00 9.8 0.9 12.2 8 9.9 1 12.6 7.6 29 6 38 305 2.2 0.1 2.7 2.2 10/10/2005 08:50:00 10.9 1.2 14.1 8.4 11 1.2 14.1 8 24 5 28 305 2.3 0.1 2.7 2.2 10/10/2005 09:00:00 9.9 0.9 12.6 8 10.1 0.9 12.6 7.2 23 6 27 305 2.3 0.1 2.7 2.2 10/10/2005 09:10:00 9.4 0.8 11.1 7.6 9.5 0.8 11.1 7.6 29 6 33 305 2.2 0.1 2.7 2.2 10/10/2005 09:20:00 9.4 0.6 11.1 7.6 9.4 0.6 11.1 7.2 30 4 36 305 2.2 0.1 2.7 2.2 10/10/2005 09:30:00 9.4 1 11.8 6.8 9.5 0.9 11.8 7.6 32 6 36 305 2.2 0 2.5 2 10/10/2005 09:40:00 9.2 0.8 11.5 7.2 9.3 0.9 11.5 7.2 32 5 27 305 2.2 0 2.5 2 10/10/2005 09:50:00 9.5 0.8 11.8 6.8 9.6 0.9 11.8 7.2 36 7 34 305 2.2 0 2.5 2 10/10/2005 10:00:00 10.1 1 12.2 7.2 10.2 1 12.2 7.2 34 6 35 305 2.2 0 2.5 2 10/10/2005 10:10:00 9.5 0.8 11.5 7.2 9.7 0.8 11.8 7.6 31 6 41 305 2.2 0 2.5 2 10/10/2005 10:20:00 9.4 0.8 11.5 7.6 9.5 0.8 11.8 7.2 35 6 43 305 2.2 0 2.5 2 10/10/2005 10:30:00 9.4 1 11.1 7.2 9.5 1 11.8 7.2 37 5 43 305 2.1 0 2.5 2 10/10/2005 10:40:00 8.2 0.8 10.7 6.1 8.3 0.8 10.3 6.5 39 5 37 305 2.2 0 2.5 2 10/10/2005 10:50:00 9.3 0.8 11.5 7.6 9.4 0.8 11.5 7.6 40 6 39 305 2.1 0 2.5 2 10/10/2005 11:00:00 9.2 0.8 12.2 7.2 9.2 0.9 11.8 6.8 40 5 41 305 2.1 0 2.5 2 10/10/2005 11:10:00 9 1 11.1 6.8 9.1 0.9 11.5 6.8 36 5 41 305 2.2 0 2.5 2 10/10/2005 11:20:00 8.3 0.5 9.5 6.8 8.4 0.6 9.9 6.5 38 4 36 305 2.2 0 2.5 2 10/10/2005 11:30:00 9 1 11.5 5.7 9.2 1 11.5 6.1 34 5 37 305 2.2 0 2.5 2 10/10/2005 11:40:00 8.2 0.6 9.5 6.5 8.4 0.6 9.9 6.8 27 8 28 305 2.2 0 2.7 2 10/10/2005 11:50:00 7.9 0.9 11.1 5.3 8.1 0.8 10.3 5.7 24 4 29 305 2.1 0 2.5 2 10/10/2005 12:00:00 8.5 0.9 10.7 6.5 8.7 0.9 11.1 6.8 25 5 26 305 2.1 0 2.5 2 10/10/2005 12:10:00 7.9 0.7 9.9 6.1 8.1 0.8 10.3 6.1 26 7 28 305 2.1 0 2.5 2 10/10/2005 12:20:00 7.6 1 10.3 5.3 7.9 1 11.1 5.7 13 10 20 305 2.1 0 2.5 2 10/10/2005 12:30:00 6.8 0.7 8.8 4.9 7.1 0.7 9.5 5.3 19 8 21 305 2.1 0 2.5 2 10/10/2005 12:40:00 7 0.6 8 5.3 7.2 0.6 8.8 5.3 22 5 23 305 2.2 0 2.5 2 10/10/2005 12:50:00 7.3 0.7 9.1 5.7 7.5 0.7 9.1 5.7 29 5 31 305 2.1 0 2.5 2 10/10/2005 13:00:00 7.4 0.6 8.8 6.1 7.7 0.5 8.8 6.5 28 3 30 305 2.1 0 2.5 2 10/10/2005 13:10:00 6.4 0.4 7.6 5.3 6.6 0.5 8 5.3 31 9 14 305 2.1 0 2.5 2 10/10/2005 13:20:00 6.6 1 8.4 4.2 6.8 1 8.8 4.9 18 9 21 305 2 0 2.5 2 10/10/2005 13:30:00 7.2 0.5 8.8 6.1 7.5 0.5 9.1 6.1 23 7 19 305 2 0 2.5 2 10/10/2005 13:40:00 7.8 0.9 9.5 6.1 8.2 0.9 9.9 6.1 10 5 8 305 2 0.1 2.5 2 10/10/2005 13:50:00 8.7 0.7 10.3 6.8 9 0.7 11.1 6.5 12 10 9 305 1.9 0.1 2.2 1.5 10/10/2005 14:00:00 8.5 1 10.7 5.7 8.8 1.1 11.1 6.1 21 5 21 305 1.9 0.1 2.2 1.5 10/10/2005 14:10:00 10 0.7 11.1 8 10.1 0.8 11.5 8 14 5 18 305 2 0 2.5 2 10/10/2005 14:20:00 9.9 0.7 11.5 8 10.1 0.8 11.8 8 10 4 5 305 2 0.1 2.5 1.7 10/10/2005 14:30:00 8.9 0.8 11.1 6.5 9.2 0.8 11.1 6.5 5 4 6 305 1.9 0.1 2.5 1.5 10/10/2005 14:40:00 9.6 0.6 11.1 7.2 9.9 0.7 11.5 8 8 4 8 305 1.7 0.2 2.5 1.5 10/10/2005 14:50:00 8.2 1.3 11.1 5.7 8.5 1.4 11.8 5.7 13 5 10 305 1.4 0.3 2.2 1 10/10/2005 15:00:00 8 1.3 11.1 6.1 8.2 1.3 11.1 6.1 21 6 14 305 1.4 0.1 2.2 1.3 10/10/2005 15:10:00 10 0.8 11.5 7.6 10.3 0.8 12.2 8 15 3 15 305 1.1 0.2 1.7 0.6 10/10/2005 15:20:00 6.4 1 8.4 3.8 6.7 1 8.8 4.2 23 8 13 305 0.5 0.2 1.3 0.1 10/10/2005 15:30:00 9.6 2 12.2 5.3 9.9 2 12.2 4.9 15 6 12 305 0.6 0.2 1.3 0.1 10/10/2005 15:40:00 9.8 0.8 11.1 7.6 10.1 0.9 12.2 6.8 10 6 13 305 0.8 0 1.3 0.6 10/10/2005 15:50:00 10.2 0.8 12.2 8.4 10.5 0.9 12.2 8.4 12 4 6 305 0.9 0 1.3 0.8 10/10/2005 16:00:00 7.4 1.2 9.5 4.6 7.8 1.2 9.9 4.9 2 5 4 305 1 0 1.5 0.8 10/10/2005 16:10:00 9.5 1.3 11.8 6.1 9.8 1.3 11.8 5.7 359 5 359 305 1 0.2 1.5 0.6 10/10/2005 16:20:00 9 0.4 9.9 7.6 9.3 0.5 10.3 7.6 359 3 355 305 1 0.1 1.5 0.8 10/10/2005 16:30:00 9.1 0.6 10.7 6.8 9.4 0.6 11.1 7.2 0 5 0 305 1.2 0.1 1.7 0.8 10/10/2005 16:40:00 7.2 0.8 9.1 5.7 7.5 0.9 9.9 6.1 13 10 358 305 0.5 0 1.3 0.3 10/10/2005 16:50:00 5.5 0.6 7.2 4.6 5.9 0.6 7.6 4.6 23 5 28 305 0.5 0 1 0.3 10/10/2005 17:00:00 5.4 0.4 6.5 4.6 5.9 0.4 6.8 4.6 11 4 18 305 0.7 0.1 1.3 0.6 10/10/2005 17:10:00 6 0.8 7.6 4.6 6.4 0.8 8 4.6 16 5 10 305 1.2 0.1 1.7 1 10/10/2005 17:20:00 6 0.8 9.1 4.2 6.3 0.9 9.1 4.6 11 6 21 305 1.4 0 2 1.3 10/10/2005 17:30:00 6 0.8 8.8 3.8 6.3 0.8 8.8 4.2 7 7 7 305 1.4 0 2 1.3 10/10/2005 17:40:00 9.4 0.7 11.1 7.6 9.8 0.8 11.5 8 357 4 355 305 1.3 0.2 2.2 1 10/10/2005 17:50:00 8.7 0.7 11.1 7.2 9 0.8 11.5 7.6 358 4 355 305 0.9 0.1 1.5 0.6 10/10/2005 18:00:00 7.9 0.5 9.1 6.5 8.3 0.5 9.5 6.8 354 5 359 305 0.6 0.1 1.3 0.6 10/10/2005 18:10:00 8.5 0.6 9.9 6.8 8.8 0.7 10.7 7.2 356 4 352 305 0.5 0 1 0.6 10/10/2005 18:20:00 7 0.8 8.8 5.3 7.4 0.8 9.5 5.7 354 3 352 305 0.5 0 1 0.6 10/10/2005 18:30:00 5.8 0.6 6.8 4.2 6.2 0.6 7.2 4.6 352 4 354 305 0.9 0 1.5 0.6 10/10/2005 18:40:00 5.6 0.8 7.2 3.4 5.9 0.9 7.6 3.8 351 5 348 305 1 0 1.5 1 10/10/2005 18:50:00 7.1 0.6 9.5 5.7 7.3 0.6 9.9 6.1 6 9 0 305 1.3 0 2 1 10/10/2005 19:00:00 8.5 1.3 11.1 6.1 8.9 1.4 11.8 5.7 1 7 357 305 1.3 0.1 2 1 10/10/2005 19:10:00 8.4 0.7 9.9 6.1 9 0.7 10.7 6.5 349 6 358 305 0.7 0.1 1.3 0.6 10/10/2005 19:20:00 5.1 1.7 8.8 2.3 5.5 1.7 9.5 2.6 359 11 343 305 0.2 0.1 0.8 0.1 10/10/2005 19:30:00 5.7 1.4 7.6 2.3 5.9 1.6 8 2.6 358 8 358 305 0.7 0.3 1.5 0.1 10/10/2005 19:40:00 8.4 1.5 10.7 5.7 8.8 1.6 11.1 6.1 345 4 340 305 0.9 0.3 1.5 0.3 10/10/2005 19:50:00 6.6 1.9 9.5 3.4 7 1.9 10.3 3.8 333 5 340 305 0 0 0.6 -0.1 10/10/2005 20:00:00 4.7 1.5 8.8 2.6 4.9 1.7 9.1 2.3 334 22 348 305 0.1 0.2 1 -0.1 10/10/2005 20:10:00 6.9 1.7 9.9 2.6 7.2 1.7 10.7 3 11 20 8 305 0.7 0.2 1.3 0.3 10/10/2005 20:20:00 7.6 0.7 9.5 5.7 7.9 0.7 9.9 6.1 9 6 8 305 1.2 0.1 1.7 1 10/10/2005 20:30:00 8.2 0.7 9.9 6.5 8.5 0.7 10.3 6.8 14 3 17 305 1.2 0.1 1.7 1 10/10/2005 20:40:00 8.2 0.7 10.7 6.8 8.5 0.7 10.7 6.8 18 5 24 305 1.2 0.1 1.7 1 10/10/2005 20:50:00 7.6 0.8 9.5 5.7 8 0.8 10.3 6.1 15 6 17 305 1.2 0.1 1.5 1 10/10/2005 21:00:00 7.8 0.7 9.1 6.1 8.1 0.7 9.9 6.1 21 4 23 305 1.2 0.1 1.5 1 10/10/2005 21:10:00 7.2 0.6 9.5 6.1 7.6 0.6 9.9 6.1 14 8 2 305 1.2 0 1.5 1 10/10/2005 21:20:00 7.6 0.7 9.5 6.1 8 0.8 9.9 6.1 21 4 18 305 1.2 0 1.5 1 10/10/2005 21:30:00 7.2 0.8 9.1 4.9 7.4 0.8 9.1 5.3 22 5 19 305 1.2 0.1 2 1 10/10/2005 21:40:00 7.2 0.8 9.1 5.7 7.4 0.8 9.5 5.7 18 5 17 305 1.2 0.1 1.7 1 10/10/2005 21:50:00 7.4 0.7 9.9 5.3 7.7 0.8 9.9 5.3 20 6 16 305 1.1 0 1.5 1 10/10/2005 22:00:00 8 0.9 9.9 5.7 8.2 0.9 10.3 6.1 22 6 29 305 1 0 1.5 1 10/10/2005 22:10:00 7.5 0.7 9.1 6.1 7.7 0.7 9.1 6.1 31 6 33 305 1 0 1.5 0.8 10/10/2005 22:20:00 7.1 0.6 8.4 4.9 7.3 0.6 8.8 5.7 28 7 27 305 1 0 1.5 1 10/10/2005 22:30:00 6.7 0.6 8.4 4.9 7 0.6 8.4 5.3 26 6 18 305 1 0 1.3 0.8 10/10/2005 22:40:00 6.5 0.6 8 4.9 6.7 0.6 8.4 5.3 35 6 37 305 1 0 1.3 0.8 10/10/2005 22:50:00 7 0.8 9.1 4.6 7.2 0.9 9.5 4.6 32 5 29 305 0.9 0 1.3 0.8 10/10/2005 23:00:00 7.5 0.7 9.1 5.7 7.7 0.8 9.5 5.7 40 8 41 305 1 0 1.3 0.8 10/10/2005 23:10:00 7.7 0.6 8.8 6.1 7.9 0.6 9.1 6.5 39 8 46 305 1 0 1.3 0.8 10/10/2005 23:20:00 7.1 0.8 8.8 5.3 7.3 0.8 9.1 5.7 35 6 42 305 1 0 1.5 0.8 10/10/2005 23:30:00 6.9 0.7 8.8 4.9 7.2 0.7 8.8 5.3 35 5 41 305 1 0 1.5 0.8 10/10/2005 23:40:00 6.1 1.2 9.1 3.8 6.3 1.2 9.1 4.2 36 10 48 305 0.9 0 1.3 0.8 10/10/2005 23:50:00 5.8 0.7 7.2 3.8 6.1 0.7 7.6 4.6 41 7 49 305 0.9 0 1.3 0.8 10/11/2005 00:00:00 6.4 0.7 8.8 4.6 6.7 0.7 8.8 4.9 33 6 38 305 0.9 0.1 1.5 0.6 10/11/2005 00:10:00 5.4 0.6 6.8 4.2 5.7 0.6 7.2 4.6 39 6 32 305 0.7 0.1 1.3 0.6 10/11/2005 00:20:00 4.5 0.6 6.5 3.4 4.9 0.6 6.5 3.8 37 9 39 305 0.7 0.1 1.3 0.6 10/11/2005 00:30:00 4.4 0.7 5.7 3 4.7 0.7 6.1 3 41 12 34 305 0.7 0.1 1.3 0.6 10/11/2005 00:40:00 4.9 0.7 6.5 3.4 5.2 0.7 6.8 3.4 35 10 32 305 0.9 0 1.3 0.8 10/11/2005 00:50:00 5.8 0.6 8 4.6 6.2 0.6 8.4 4.6 43 6 38 305 0.8 0.1 1.3 0.6 10/11/2005 01:00:00 6.2 1.2 8.8 3.8 6.5 1.1 9.1 4.2 43 5 36 305 0.3 0.2 1 0.1 10/11/2005 01:10:00 4.5 0.4 5.3 3.8 4.7 0.4 5.7 3.4 63 8 50 305 0.1 0 0.6 0.1 10/11/2005 01:20:00 3.6 0.5 4.6 2.6 3.7 0.5 4.9 2.6 68 5 82 305 0 0.1 0.6 0.1 10/11/2005 01:30:00 2.4 0.5 3.8 1.5 2.5 0.4 4.2 1.9 60 9 65 305 0.1 0.1 0.6 0.1 10/11/2005 01:40:00 1.6 0.5 2.6 0.4 1.8 0.4 2.6 0.7 80 9 79 305 0 0 0.6 -0.1 10/11/2005 01:50:00 3.8 1.3 6.5 1.1 3.8 1.3 6.1 1.5 50 13 48 305 0.2 0.1 0.6 -0.1 10/11/2005 02:00:00 4 0.9 5.7 1.9 4.4 0.8 6.1 2.3 24 16 35 305 0.3 0 0.6 0.1 10/11/2005 02:10:00 5 0.6 6.5 3.4 5.3 0.6 6.8 3.8 18 8 30 305 0.1 0.1 0.6 -0.4 10/11/2005 02:20:00 3.2 1.5 6.1 1.1 3.5 1.6 6.1 1.5 26 9 26 305 -0.8 0.3 0.1 -1.3 10/11/2005 02:30:00 4.6 0.5 6.1 3.4 4.7 0.6 6.1 3.4 65 7 62 305 -1.2 0.1 -0.6 -1.5 10/11/2005 02:40:00 3 0.9 4.6 1.1 3.1 0.8 4.6 1.5 67 12 79 305 -1.4 0 -1.1 -1.5 10/11/2005 02:50:00 2.3 0.5 3 1.1 2.3 0.4 3 1.1 59 14 78 305 -1.2 0 -0.6 -1.3 10/11/2005 03:00:00 1.7 0.5 2.6 0.7 2 0.4 3 1.1 42 7 48 305 -0.7 0.1 -0.4 -1.1 10/11/2005 03:10:00 0.6 0.3 1.5 0.4 0.9 0.4 2.3 0.4 33 18 43 305 -0.5 0 -0.1 -0.6 10/11/2005 03:20:00 1 1 4.6 0.4 1.3 0.8 3.8 0.4 337 23 359 305 -0.7 0 -0.4 -0.8 10/11/2005 03:30:00 5.7 1.3 7.6 2.6 6 1.4 8 2.6 334 6 337 305 -0.1 0.2 0.6 -0.6 10/11/2005 03:40:00 6.3 0.5 7.6 4.6 6.6 0.5 7.6 4.9 330 5 326 305 -0.1 0 0.3 -0.4 10/11/2005 03:50:00 6.2 0.5 7.2 5.3 6.7 0.5 7.6 5.3 330 4 329 305 -0.1 0 0.3 -0.1 10/11/2005 04:00:00 6.2 0.5 7.6 4.9 6.6 0.5 8 5.3 332 5 326 305 -0.1 0 0.3 -0.1 10/11/2005 04:10:00 5.3 0.5 6.1 4.2 5.7 0.5 6.8 4.6 342 5 340 305 -0.1 0 0.3 -0.1 10/11/2005 04:20:00 5 0.5 6.1 3.8 5.4 0.5 6.8 4.2 344 6 339 305 0 0 0.3 0.1 10/11/2005 04:30:00 4.9 0.4 6.1 3.8 5.4 0.4 6.8 4.6 353 4 355 305 0.2 0 0.6 0.1 10/11/2005 04:40:00 4.6 0.6 5.7 3.4 5.1 0.6 6.5 3.8 354 6 348 305 0.3 0 0.3 0.1 10/11/2005 04:50:00 4.5 0.7 6.1 3 4.9 0.7 6.8 3 357 7 3 305 0.2 0 0.8 0.1 10/11/2005 05:00:00 4.1 0.5 5.3 3 4.5 0.5 5.7 3.4 352 5 357 305 0.2 0 0.6 0.1 10/11/2005 05:10:00 4.1 0.5 5.3 3 4.6 0.5 6.1 3.4 355 8 348 305 0.2 0 0.3 0.1 10/11/2005 05:20:00 4.3 0.5 5.7 3 4.8 0.5 6.1 3.4 1 6 358 305 0.2 0 0.6 0.1 10/11/2005 05:30:00 4.7 0.6 6.1 3 5.1 0.6 6.8 3.4 2 5 359 305 0.3 0 0.6 0.1 10/11/2005 05:40:00 5.3 0.8 6.8 3.4 5.6 0.8 7.2 4.2 2 4 359 305 0.3 0 0.6 0.1 10/11/2005 05:50:00 6.5 0.6 7.6 4.9 6.8 0.6 8.4 5.3 8 6 8 305 0.4 0 0.6 0.3 10/11/2005 06:00:00 6.2 0.6 7.6 4.6 6.6 0.6 8 5.3 10 6 5 305 0.3 0 0.8 0.3 10/11/2005 06:10:00 6.9 0.5 8 5.3 7.2 0.6 8.4 5.7 14 6 14 305 0.3 0 0.6 0.1 10/11/2005 06:20:00 6.2 0.7 8 4.2 6.6 0.7 8.4 4.6 14 4 21 305 0.2 0.1 0.6 0.1 10/11/2005 06:30:00 6.2 0.6 7.6 4.6 6.4 0.6 8.4 4.9 21 7 15 305 0.2 0 0.8 0.1 10/11/2005 06:40:00 7 0.7 8.8 4.9 7.3 0.6 8.8 4.9 21 6 12 305 0.3 0 0.8 0.1 10/11/2005 06:50:00 7.1 0.6 8.8 5.3 7.4 0.6 9.1 6.1 22 7 32 305 0.2 0 0.6 0.1 10/11/2005 07:00:00 7.4 0.6 8.8 5.7 7.7 0.6 8.8 6.1 19 5 23 305 0.2 0.1 0.6 0.1 10/11/2005 07:10:00 7.5 0.5 9.1 6.1 7.7 0.6 9.1 6.5 23 6 26 305 0.2 0.1 0.6 0.1 10/11/2005 07:20:00 7.5 0.5 8.8 6.1 7.7 0.5 8.8 6.5 23 5 25 305 0.2 0 0.6 0.1 10/11/2005 07:30:00 7.7 0.6 9.5 5.7 7.9 0.7 9.5 6.5 25 6 27 305 0.2 0 0.8 0.1 10/11/2005 07:40:00 7.7 0.5 9.1 6.5 7.9 0.6 9.5 6.5 25 4 27 305 0.3 0 0.8 0.1 10/11/2005 07:50:00 7.2 0.7 8.8 5.7 7.4 0.7 9.1 5.7 24 6 28 305 0.3 0 0.6 0.1 10/11/2005 08:00:00 7.5 0.5 8.8 5.7 7.6 0.6 9.1 5.7 32 4 37 305 0.2 0 0.6 0.1 10/11/2005 08:10:00 7 0.6 8.8 5.3 7.2 0.6 8.8 5.7 22 6 24 305 0.3 0 0.6 0.1 10/11/2005 08:20:00 7.6 0.6 9.1 6.1 7.9 0.6 9.1 6.5 21 5 19 305 0.3 0 0.6 0.3 10/11/2005 08:30:00 7.6 0.6 9.1 6.1 7.9 0.6 9.5 6.5 21 5 24 305 0.3 0 0.8 0.3 10/11/2005 08:40:00 7.1 0.5 8 5.7 7.4 0.5 8.8 6.5 21 5 28 305 0.4 0 0.6 0.3 10/11/2005 08:50:00 6.9 0.5 8.4 6.1 7.2 0.5 8.8 5.7 30 6 37 305 0.4 0 1 0.3 10/11/2005 09:00:00 6.5 0.6 8.8 4.9 6.7 0.6 9.1 5.3 36 9 37 305 0.4 0 0.6 0.3 10/11/2005 09:10:00 5.9 0.9 7.6 3.4 6.1 1 7.6 3.4 55 13 57 305 0.5 0 0.6 0.3 10/11/2005 09:20:00 4.1 0.9 6.5 2.3 4.1 0.9 6.8 2.3 111 10 96 305 0.1 0.2 0.6 -0.1 10/11/2005 09:30:00 1.9 1 4.9 0.4 2.1 0.9 4.2 0.4 78 24 66 305 0 0 0.3 -0.4 10/11/2005 09:40:00 2.4 1 4.2 0.4 2.6 1 4.6 0.4 112 16 131 305 0.1 0 0.3 0.1 10/11/2005 09:50:00 4.1 0.5 5.3 2.3 4.2 0.5 5.3 2.3 131 5 138 305 -0.1 0 0.1 -0.1 10/11/2005 10:00:00 4.1 0.3 4.6 3.4 4.2 0.3 4.9 3.4 142 3 138 305 0 0 0.1 0.1 10/11/2005 10:10:00 4.4 0.3 5.3 3.8 4.7 0.3 5.3 3.8 135 3 135 305 0 0 0.6 0.1 10/11/2005 10:20:00 4.1 0.3 4.9 3.4 4.3 0.3 5.3 3.4 136 4 140 305 0 0 0.3 0.1 10/11/2005 10:30:00 3.8 0.3 4.6 2.6 3.9 0.4 4.9 3 134 4 134 305 0.3 0.1 1 0.1 10/11/2005 10:40:00 3.3 0.4 4.6 2.3 3.4 0.4 4.6 2.6 135 7 134 305 0.5 0 1 0.3 10/11/2005 10:50:00 2.9 0.5 4.2 1.5 3.1 0.5 4.6 1.9 133 5 138 305 0.5 0 1 0.6 10/11/2005 11:00:00 2 0.6 3 0.4 2.5 0.4 3 1.1 144 11 133 305 0.6 0.1 1 0.6 10/11/2005 11:10:00 1.9 0.6 3 0.7 2.9 0.5 3.8 1.5 176 8 184 305 0.6 0.2 1 0.1 10/11/2005 11:20:00 3.4 0.3 3.8 2.3 3.7 0.4 4.2 2.3 189 2 192 305 0 0.1 0.6 -0.1 10/11/2005 11:30:00 3.1 0.3 3.4 1.9 3.4 0.3 4.2 2.3 191 3 186 305 0 0 0.3 -0.1 10/11/2005 11:40:00 3 0.3 3.4 2.3 3.3 0.3 3.8 2.6 194 3 193 305 -0.1 0 0.3 -0.4 10/11/2005 11:50:00 2.5 0.3 3 1.9 2.9 0.3 3.4 2.3 196 3 196 305 0 0 0.6 -0.1 10/11/2005 12:00:00 2.3 0.3 3 1.5 2.7 0.3 3.4 1.9 196 6 213 305 0.2 0.1 0.6 0.1 10/11/2005 12:10:00 1.9 0.4 3 1.1 2.3 0.4 3.4 1.5 203 6 196 305 0.4 0 1 0.1 10/11/2005 12:20:00 1.7 0.4 2.6 0.4 2.1 0.3 3 1.1 201 5 208 305 0.6 0.1 1.3 0.6 10/11/2005 12:30:00 0.8 0.4 1.5 0.4 1.6 0.3 2.3 0.7 200 7 202 305 0.9 0 1.5 0.6 10/11/2005 12:40:00 1.2 0.5 2.3 0.4 1.7 0.4 2.6 0.7 203 11 192 305 1 0 1.5 0.8 10/11/2005 12:50:00 1.8 0.5 3 0.4 2.3 0.4 3.4 1.5 207 10 199 305 1 0 1.5 1 10/11/2005 13:00:00 2.2 0.4 3.4 1.1 2.6 0.4 3.4 1.5 202 4 205 305 1 0 1.3 1 10/11/2005 13:10:00 2.1 0.4 3 1.1 2.5 0.3 3 1.9 205 6 210 305 1 0.1 1.5 0.8 10/11/2005 13:20:00 1.5 0.5 2.6 0.4 2 0.4 3 1.1 209 10 209 305 1.2 0.1 1.7 1 10/11/2005 13:30:00 1.2 0.5 2.3 0.4 1.7 0.3 2.6 0.7 218 11 234 305 1.7 0.2 2.2 1.3 10/11/2005 13:40:00 0.6 0.4 1.9 0.4 1.2 0.4 2.3 0.4 215 19 218 305 1.9 0.2 2.5 1.5 10/11/2005 13:50:00 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 258 15 256 305 1.7 0.1 2.2 1.5 10/11/2005 14:00:00 3.6 0.8 4.9 0.4 4.1 0.8 5.3 0.7 12 7 10 305 1 0.4 2.2 0.3 10/11/2005 14:10:00 3.7 0.3 4.6 2.6 4.1 0.3 5.3 3 31 11 42 305 0.4 0 1 0.1 10/11/2005 14:20:00 4 0.4 5.3 3 4.3 0.4 5.7 3.4 51 6 54 305 0.3 0.2 0.8 0.1 10/11/2005 14:30:00 4 0.3 4.6 3 4.4 0.4 5.3 3 51 6 60 305 0.4 0.1 1 0.1 10/11/2005 14:40:00 3.7 0.4 4.9 3 4.1 0.4 4.9 3.4 50 4 48 305 0.6 0.1 1 0.3 10/11/2005 14:50:00 3 0.5 4.2 1.9 3.4 0.5 4.6 2.3 58 6 58 305 0.6 0.1 1 0.3 10/11/2005 15:00:00 1 0.7 2.6 0.4 1.7 0.6 3.4 0.4 44 16 52 305 1.2 0.4 2 0.6 10/11/2005 15:10:00 0.7 0.6 2.6 0.4 1.1 0.6 3 0.4 99 90 217 305 2.4 0.5 3.7 1.5 10/11/2005 15:20:00 1.6 0.6 3 0.4 2.1 0.4 3.4 1.1 201 14 241 305 2.5 0.3 3.4 2 10/11/2005 15:30:00 0.9 0.5 2.3 0.4 1.5 0.4 2.6 0.7 194 26 189 305 2.4 0.1 2.7 2 10/11/2005 15:40:00 1 0.6 2.3 0.4 1.5 0.6 2.6 0.4 221 15 208 305 2.5 0 2.7 2.2 10/11/2005 15:50:00 1 0.5 2.3 0.4 1.5 0.4 2.6 0.7 235 16 231 305 2 0.1 2.5 2 10/11/2005 16:00:00 0.9 0.9 3.8 0.4 1.3 0.8 4.2 0.4 263 39 315 305 2.5 0.3 3.4 2.2 10/11/2005 16:10:00 0.6 0.3 1.9 0.4 1 0.4 1.9 0.4 264 43 252 305 2.8 0.1 3.4 2.5 10/11/2005 16:20:00 1 0.5 2.3 0.4 1.3 0.4 2.3 0.4 266 39 234 305 2.6 0 2.9 2.5 10/11/2005 16:30:00 1.3 0.5 2.6 0.4 1.7 0.4 3 0.7 328 17 313 305 2.5 0 2.7 2.2 10/11/2005 16:40:00 1.3 0.5 2.3 0.4 1.8 0.4 2.6 0.7 316 11 323 305 2.3 0 2.5 2.2 10/11/2005 16:50:00 1.7 0.4 3 0.4 1.6 0.4 3.4 0.7 283 22 302 305 2.4 0.1 2.7 2.2 10/11/2005 17:00:00 0.7 0.5 2.3 0.4 1 0.4 2.3 0.4 270 29 238 305 2.1 0 2.2 2 10/11/2005 17:10:00 1.3 0.5 2.3 0.4 1.7 0.3 2.3 0.7 313 10 328 305 2.1 0 2.2 2 10/11/2005 17:20:00 1.1 0.4 2.3 0.4 1.3 0.4 2.6 0.7 289 17 303 305 2.3 0 2.5 2.2 10/11/2005 17:30:00 0.9 0.5 2.3 0.4 1.4 0.5 2.6 0.4 328 13 326 305 2.3 0.1 2.7 2.2 10/11/2005 17:40:00 0.9 0.4 1.9 0.4 1.5 0.3 2.3 0.7 349 12 359 305 2.1 0 2.5 2 10/11/2005 17:50:00 0.6 0.3 1.5 0.4 1.2 0.3 1.9 0.4 14 11 24 305 2 0 2.2 2 10/11/2005 18:00:00 0.7 0.4 2.3 0.4 1.2 0.4 2.3 0.4 23 13 35 305 1.9 0 2 1.7 10/11/2005 18:10:00 1.3 0.4 2.3 0.7 1.7 0.3 2.3 1.1 50 7 42 305 1.6 0 2 1.3 10/11/2005 18:20:00 1.1 0.3 1.9 0.4 1.5 0.2 1.9 1.1 47 4 48 305 1.4 0 1.5 1.3 10/11/2005 18:30:00 2.2 0.7 3.8 0.7 2.3 0.6 3.8 1.1 59 10 60 305 1.2 0 1.5 1.3 10/11/2005 18:40:00 2.7 0.4 3.8 1.9 2.7 0.4 3.4 1.9 59 8 74 305 0.8 0.2 1.3 0.6 10/11/2005 18:50:00 2 0.3 2.6 1.1 2 0.3 3 1.1 72 9 54 305 0.4 0 0.6 0.3 10/11/2005 19:00:00 2.3 0.4 3.4 1.1 2.3 0.4 3 1.5 76 6 68 305 0.2 0.1 0.3 0.1 10/11/2005 19:10:00 2 0.4 3.4 1.1 2.1 0.4 3 1.5 79 6 75 305 0 0 0.3 -0.1 10/11/2005 19:20:00 1.1 0.4 1.9 0.4 1.4 0.3 1.9 0.7 82 4 87 305 -0.4 0.1 0.1 -0.6 10/11/2005 19:30:00 1.3 0.3 1.9 0.4 1.6 0.3 2.3 1.1 78 0 78 305 -0.7 0 -0.4 -0.8 10/11/2005 19:40:00 1 0.4 1.9 0.4 1.4 0.3 1.9 0.7 73 6 79 305 -0.8 0 -0.6 -1.1 10/11/2005 19:50:00 0.9 0.3 1.5 0.4 1.3 0.2 1.5 0.7 72 3 73 305 -0.9 0 -0.6 -1.1 10/11/2005 20:00:00 0.5 0.2 1.1 0.4 1.1 0.3 1.5 0.4 64 0 64 305 -1 0.1 -0.6 -1.1 10/11/2005 20:10:00 0.4 0.1 0.7 0.4 1.1 0.2 1.5 0.7 81 5 65 305 -1 0.1 -0.6 -1.1 10/11/2005 20:20:00 0.4 0 0.7 0.4 0.8 0.2 1.5 0.4 85 0 85 305 -0.7 0 -0.4 -0.8 10/11/2005 20:30:00 0.5 0.2 1.1 0.4 1.2 0.2 1.5 0.7 85 0 85 305 -1 0.1 -0.4 -1.3 10/11/2005 20:40:00 0.7 0.6 2.6 0.4 1.2 0.4 2.6 0.4 77 14 57 305 -1 0.1 -0.4 -1.1 10/11/2005 20:50:00 2.9 1.5 5.7 0.4 2.9 1.5 6.1 0.7 39 12 29 305 -0.4 0.3 0.3 -1.1 10/11/2005 21:00:00 4.8 0.5 6.5 3.4 5.1 0.5 6.8 3.8 32 5 29 305 0.3 0 0.6 0.1 10/11/2005 21:10:00 6.1 0.5 7.6 4.9 6.4 0.5 7.6 4.9 33 8 31 305 0.3 0 0.6 0.1 10/11/2005 21:20:00 5.3 0.6 6.8 3.8 5.7 0.6 7.2 4.6 36 6 29 305 0.2 0.1 0.6 0.1 10/11/2005 21:30:00 4.9 0.6 6.1 3.8 5.2 0.6 6.5 4.2 48 8 50 305 0.1 0.1 0.6 -0.1 10/11/2005 21:40:00 5.3 0.6 6.5 4.2 5.7 0.5 6.8 4.6 51 5 50 305 -0.1 0 0.3 -0.4 10/11/2005 21:50:00 5.2 0.4 6.5 4.2 5.5 0.5 6.5 4.2 55 5 62 305 -0.3 0.1 0.1 -0.6 10/11/2005 22:00:00 4.7 0.5 5.7 3.4 5.1 0.6 6.5 3.4 46 6 46 305 -0.5 0.1 0.1 -0.6 10/11/2005 22:10:00 4.5 0.5 5.7 3.4 4.8 0.5 6.5 3.4 41 7 43 305 -0.7 0.1 -0.1 -1.1 10/11/2005 22:20:00 4.6 0.5 6.1 3 4.9 0.5 6.1 3 41 6 40 305 -0.7 0.1 -0.4 -1.1 10/11/2005 22:30:00 4.7 0.4 5.3 3.8 5 0.4 5.7 3.8 28 5 36 305 -0.5 0.2 0.1 -1.1 10/11/2005 22:40:00 3.9 0.5 4.9 3 4.2 0.5 5.7 3 34 8 24 305 -0.4 0.2 0.1 -0.6 10/11/2005 22:50:00 2.6 0.3 3.4 1.9 2.8 0.3 3.8 1.9 23 9 40 305 -0.3 0.2 0.3 -0.4 10/11/2005 23:00:00 1.8 0.7 3 0.4 2.1 0.6 3 0.7 27 12 16 305 0 0.2 0.6 -0.4 10/11/2005 23:10:00 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 28 9 33 305 0.1 0.1 0.6 -0.1 10/11/2005 23:20:00 0.5 0.3 1.9 0.4 0.9 0.4 2.3 0.4 151 56 200 305 -0.1 0.2 0.3 -0.4 10/11/2005 23:30:00 0.8 0.4 1.9 0.4 1.3 0.4 1.9 0.4 228 15 242 305 -0.3 0.2 0.1 -0.4 10/11/2005 23:40:00 1 0.6 2.6 0.4 1.6 0.5 2.6 0.7 203 19 184 305 -0.4 0.2 0.1 -0.6 10/11/2005 23:50:00 1.5 0.4 2.3 0.4 2.3 0.3 3 1.5 174 16 185 305 -0.5 0.1 0.1 -0.6 10/12/2005 00:00:00 2.4 0.6 3.8 1.1 2.6 0.5 4.2 1.5 110 9 105 305 -0.4 0.1 0.1 -0.6 10/12/2005 00:10:00 0.9 0.6 2.3 0.4 1.3 0.7 2.6 0.4 102 23 119 305 -0.4 0.1 0.1 -0.6 10/12/2005 00:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 119 0 305 305 -0.4 0.1 0.1 -0.6 10/12/2005 00:30:00 0.4 0 0.4 0.4 0.6 0.2 1.5 0.4 124 17 305 305 -0.4 0.1 0.1 -0.6 10/12/2005 00:40:00 0.4 0.1 1.1 0.4 1.1 0.3 1.9 0.4 199 11 184 305 -0.3 0.1 0.1 -0.4 10/12/2005 00:50:00 0.8 0.7 2.6 0.4 0.8 0.5 2.3 0.4 147 45 119 305 -0.4 0.1 0.1 -0.6 10/12/2005 01:00:00 3 0.4 3.8 1.9 2.9 0.7 4.2 1.1 135 8 136 305 -0.9 0.2 -0.4 -1.1 10/12/2005 01:10:00 3.5 0.4 4.6 2.6 3.8 0.4 4.9 3 121 3 116 305 -0.9 0.1 -0.4 -1.1 10/12/2005 01:20:00 4.1 0.3 4.9 3.4 4.4 0.3 4.9 3.8 116 5 112 305 -0.6 0.2 0.1 -0.8 10/12/2005 01:30:00 4.4 0.3 4.9 3.8 4.6 0.3 5.3 3.8 111 3 119 305 -0.4 0.2 0.1 -0.6 10/12/2005 01:40:00 4.6 0.5 5.3 3 4.7 0.4 5.7 3.4 109 6 118 305 -0.3 0.2 0.1 -0.4 10/12/2005 01:50:00 4.6 0.6 5.7 3 4.6 0.5 5.7 2.6 100 6 108 305 -0.3 0.2 0.1 -0.6 10/12/2005 02:00:00 4.2 0.4 4.9 3 4.2 0.4 4.9 3 85 6 90 305 -0.1 0.1 0.3 -0.4 10/12/2005 02:10:00 3.9 0.4 4.9 2.6 3.9 0.3 4.9 3 81 5 85 305 -0.2 0.2 0.3 -0.4 10/12/2005 02:20:00 3.9 0.4 4.9 2.6 4 0.4 5.3 3 72 6 59 305 -0.1 0.2 0.6 -0.4 10/12/2005 02:30:00 3.7 0.5 5.3 2.6 3.8 0.5 5.3 2.6 74 5 78 305 0 0.1 0.6 -0.4 10/12/2005 02:40:00 3.5 0.3 4.6 2.6 3.4 0.3 4.2 2.6 77 5 72 305 -0.4 0.2 0.3 -0.6 10/12/2005 02:50:00 3.4 0.5 4.6 2.3 3.4 0.4 4.2 2.6 63 15 75 305 -0.3 0.3 0.6 -0.6 10/12/2005 03:00:00 4.9 0.7 6.1 3 5.2 0.8 6.5 2.6 39 7 42 305 0.6 0.3 1.5 0.1 10/12/2005 03:10:00 5.5 0.5 6.8 4.6 5.8 0.5 7.2 4.6 34 5 27 305 0.9 0.1 1.5 0.8 10/12/2005 03:20:00 5.3 0.4 6.5 4.2 5.7 0.4 6.8 4.6 33 6 34 305 0.9 0 1.5 0.8 10/12/2005 03:30:00 5.3 0.4 6.5 4.6 5.7 0.4 6.5 4.6 33 7 29 305 1 0.1 1.5 0.8 10/12/2005 03:40:00 5.5 0.5 6.8 4.2 5.9 0.5 6.8 4.6 31 6 26 305 0.9 0 1.5 0.8 10/12/2005 03:50:00 4.9 0.5 6.1 3.8 5.3 0.5 6.5 4.2 37 6 33 305 0.9 0.1 1.5 0.8 10/12/2005 04:00:00 4.8 0.4 6.1 3.8 5.3 0.4 6.1 4.2 39 6 45 305 0.9 0.1 1.5 0.6 10/12/2005 04:10:00 4.6 0.4 5.7 3.4 5 0.4 6.1 3.8 41 5 39 305 0.8 0.1 1.3 0.6 10/12/2005 04:20:00 4.4 0.5 5.7 3.4 4.9 0.5 6.1 3.8 45 6 49 305 0.8 0.1 1.3 0.6 10/12/2005 04:30:00 4.1 0.3 5.3 3.4 4.6 0.4 5.7 3.8 36 5 43 305 0.8 0.1 1.3 0.6 10/12/2005 04:40:00 4.3 0.5 5.7 3.4 4.7 0.5 6.1 3.4 32 6 27 305 0.8 0.1 1.3 0.6 10/12/2005 04:50:00 4.8 0.4 5.7 3.8 5.3 0.4 6.1 4.2 33 4 30 305 0.8 0.2 1.3 0.6 10/12/2005 05:00:00 5.2 0.5 6.8 4.2 5.6 0.5 7.2 4.6 34 5 36 305 0.7 0.2 1.3 0.6 10/12/2005 05:10:00 4.6 0.4 5.3 3.8 5.1 0.4 6.1 4.2 26 7 38 305 0.6 0.1 1 0.6 10/12/2005 05:20:00 4.7 0.6 6.5 3.4 5.1 0.6 6.8 3.8 34 4 34 305 0.7 0.2 1.3 0.6 10/12/2005 05:30:00 4.4 0.3 4.9 3.4 4.8 0.4 6.1 4.2 31 6 33 305 0.7 0.2 1.3 0.6 10/12/2005 05:40:00 4.3 0.4 5.7 3.4 4.7 0.4 5.7 3.8 23 5 30 305 0.7 0.2 1.3 0.6 10/12/2005 05:50:00 4.4 0.5 6.1 3.4 4.9 0.5 6.1 3.8 28 7 40 305 0.7 0.2 1.3 0.6 10/12/2005 06:00:00 3.8 0.3 4.9 3 4.2 0.3 5.3 3.4 29 6 30 305 0.7 0.2 1.3 0.6 10/12/2005 06:10:00 3.9 0.4 5.3 3 4.2 0.4 5.7 3.4 27 5 25 305 0.7 0.2 1.3 0.6 10/12/2005 06:20:00 3.6 0.3 4.6 2.6 4 0.4 4.9 3 33 7 26 305 0.6 0.1 1.3 0.6 10/12/2005 06:30:00 3.7 0.4 4.9 3 4.1 0.4 5.7 3.4 30 8 33 305 0.7 0.1 1.3 0.6 10/12/2005 06:40:00 3.5 0.5 4.6 2.3 3.9 0.5 4.9 2.6 23 5 19 305 0.7 0.1 1 0.6 10/12/2005 06:50:00 3 0.3 3.8 2.3 3.4 0.4 4.2 2.3 19 6 12 305 0.7 0.1 1.3 0.6 10/12/2005 07:00:00 3.1 0.6 4.2 1.9 3.4 0.7 4.9 2.3 15 8 10 305 0.7 0.1 1.3 0.6 10/12/2005 07:10:00 2.8 0.4 4.2 1.9 3.2 0.4 4.2 2.3 20 5 21 305 0.7 0.1 1.3 0.6 10/12/2005 07:20:00 2.8 0.5 4.2 1.9 3 0.5 4.6 2.3 19 6 29 305 0.6 0.1 1.3 0.6 10/12/2005 07:30:00 2.9 0.4 3.8 1.9 3.2 0.4 4.2 2.3 11 4 11 305 0.8 0 1.3 0.6 10/12/2005 07:40:00 2.9 0.4 3.8 1.9 3.2 0.4 4.2 2.3 7 4 4 305 0.7 0.1 1.3 0.6 10/12/2005 07:50:00 3.4 0.5 4.6 2.3 3.5 0.5 4.6 2.6 7 6 8 305 0.7 0.1 1 0.6 10/12/2005 08:00:00 3.2 0.5 4.2 1.5 3.4 0.5 4.6 1.9 4 6 5 305 0.7 0 1 0.6 10/12/2005 08:10:00 2.9 0.5 4.2 1.5 3.2 0.5 4.2 2.3 12 6 18 305 0.7 0 1.3 0.6 10/12/2005 08:20:00 2.9 0.5 4.2 1.5 3.2 0.5 4.2 2.3 11 5 8 305 0.7 0 1.3 0.6 10/12/2005 08:30:00 3 0.4 4.2 1.9 3.3 0.4 4.6 2.3 11 6 17 305 0.8 0 1.3 0.6 10/12/2005 08:40:00 3.3 0.5 4.6 1.9 3.6 0.5 4.6 2.6 359 5 2 305 0.6 0 1 0.6 10/12/2005 08:50:00 2.7 0.5 3.8 1.5 3 0.4 4.2 2.3 5 5 359 305 0.7 0 1.3 0.6 10/12/2005 09:00:00 2.7 0.5 3.8 1.5 3 0.4 4.2 2.3 15 9 12 305 0.7 0 1.3 0.6 10/12/2005 09:10:00 2.5 0.5 3.4 1.5 2.9 0.4 4.2 1.9 7 9 16 305 0.6 0 1 0.6 10/12/2005 09:20:00 2.3 0.8 4.2 0.4 2.8 0.8 4.6 1.5 353 10 346 305 0.7 0.1 1.3 0.6 10/12/2005 09:30:00 2.7 0.4 3.8 1.9 3 0.4 4.2 2.3 3 9 348 305 0.7 0.1 1.3 0.6 10/12/2005 09:40:00 2.7 0.5 3.8 1.5 3 0.5 4.2 1.9 356 9 345 305 0.9 0 1.3 0.6 10/12/2005 09:50:00 2.1 0.7 3.8 1.1 2.5 0.6 4.2 1.5 346 13 351 305 0.9 0 1.3 0.6 10/12/2005 10:00:00 1.7 0.9 3 0.4 2.2 0.6 3.4 1.1 319 4 309 305 0.8 0 1.5 0.6 10/12/2005 10:10:00 1.5 0.5 2.6 0.4 1.9 0.3 2.6 1.1 301 6 301 305 0.7 0.1 1 0.6 10/12/2005 10:20:00 1.3 1.2 3.8 0.4 1.6 1 3.4 0.4 309 8 305 305 0.8 0 1.3 0.6 10/12/2005 10:30:00 2.2 0.4 3 1.1 2.5 0.3 3.4 1.9 311 5 314 305 0.7 0.1 1.3 0.6 10/12/2005 10:40:00 2.1 0.6 3.4 0.7 2.5 0.5 3.4 1.5 312 6 306 305 0.8 0.1 1.3 0.6 10/12/2005 10:50:00 1.4 1.1 4.2 0.4 2 0.8 3.8 0.7 313 7 320 305 1 0.1 1.5 0.8 10/12/2005 11:00:00 2.4 0.4 3.4 1.5 2.7 0.4 3.4 1.9 309 11 328 305 1 0.1 1.5 0.8 10/12/2005 11:10:00 1.8 0.5 3 1.1 2.2 0.4 3 1.5 304 9 300 305 0.9 0.1 1.3 0.6 10/12/2005 11:20:00 2.8 0.6 3.8 1.1 3 0.5 4.2 1.9 303 15 298 305 0.8 0.1 1.3 0.6 10/12/2005 11:30:00 2.4 0.5 3.4 1.1 2.7 0.4 3.8 1.9 314 10 317 305 1 0.1 1.5 0.8 10/12/2005 11:40:00 2.3 0.5 3.4 1.1 2.6 0.4 3.4 1.5 321 9 327 305 1 0.1 1.5 1 10/12/2005 11:50:00 2.2 0.5 3.4 0.7 2.5 0.5 3.4 1.1 303 12 296 305 1.2 0.1 1.5 1 10/12/2005 12:00:00 0.6 0.4 1.9 0.4 1 0.4 2.3 0.4 270 16 302 305 1.2 0.1 1.5 1 10/12/2005 12:10:00 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 262 9 246 305 1.2 0.1 2 1 10/12/2005 12:20:00 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 268 0 268 305 1.4 0 2 1.3 10/12/2005 12:30:00 0.8 0.4 1.9 0.4 1.2 0.4 1.9 0.4 251 15 235 305 1.5 0 2 1.3 10/12/2005 12:40:00 2.3 0.4 3 1.1 2.3 0.4 3 1.5 240 8 244 305 1.6 0 2 1.3 10/12/2005 12:50:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.5 243 7 239 305 1.4 0.1 2 1.3 10/12/2005 13:00:00 2.8 0.4 4.2 1.9 2.6 0.4 4.2 1.1 245 7 237 305 1.6 0.1 2.2 1.5 10/12/2005 13:10:00 3.4 0.6 5.3 1.9 3.3 0.6 4.9 1.9 236 7 237 305 1.9 0.2 2.5 1.5 10/12/2005 13:20:00 3.6 0.6 4.9 2.3 3.4 0.6 4.6 1.9 245 8 248 305 1.7 0.1 2.2 1.5 10/12/2005 13:30:00 3.7 0.6 4.9 1.9 3.5 0.7 4.9 2.3 248 7 251 305 1.8 0.2 2.5 1.5 10/12/2005 13:40:00 3.8 0.5 4.9 2.3 3.7 0.5 4.6 2.3 243 6 247 305 2.1 0.1 2.5 2 10/12/2005 13:50:00 4.3 0.5 5.7 3 4 0.6 5.7 2.6 240 5 245 305 2.2 0.1 2.7 2 10/12/2005 14:00:00 4.7 0.6 6.5 3 4.6 0.7 6.5 2.3 236 10 231 305 2.2 0 2.7 2 10/12/2005 14:10:00 5 0.5 6.1 3.4 4.9 0.6 6.1 3.4 227 6 222 305 2.2 0.1 2.7 2 10/12/2005 14:20:00 4.5 0.5 5.7 3 4.4 0.6 5.7 3 231 6 235 305 2.2 0.1 2.7 2 10/12/2005 14:30:00 4.7 0.4 6.1 3 4.6 0.5 5.7 3 238 8 244 305 2 0.1 2.5 2 10/12/2005 14:40:00 4.3 0.5 5.3 2.6 4.2 0.5 5.3 3 242 7 233 305 1.7 0.1 2.2 1.5 10/12/2005 14:50:00 4.2 0.8 6.1 2.3 4 0.9 5.7 2.3 237 7 229 305 1.6 0.1 2.2 1.3 10/12/2005 15:00:00 4.8 0.6 6.1 3 4.6 0.6 6.1 3 234 6 230 305 1.6 0 2 1.3 10/12/2005 15:10:00 5 0.4 6.1 3.8 5 0.4 5.7 3.8 221 6 221 305 1.7 0.2 2.2 1.5 10/12/2005 15:20:00 5.1 0.5 6.1 3.4 4.9 0.6 6.1 3.4 219 6 223 305 1.9 0.2 2.5 1.5 10/12/2005 15:30:00 4.8 0.5 5.7 3.4 4.7 0.5 5.7 3 215 5 215 305 2.2 0.1 2.5 2 10/12/2005 15:40:00 5.1 0.4 6.1 3.8 4.9 0.5 6.1 3.4 220 7 220 305 2.2 0.1 2.7 2 10/12/2005 15:50:00 5.2 0.5 6.5 3.4 4.9 0.6 6.1 3 229 5 232 305 1.9 0.2 2.5 1.5 10/12/2005 16:00:00 5.7 0.7 6.8 3.4 5.4 0.7 7.2 3.8 238 6 238 305 1.8 0.1 2.2 1.5 10/12/2005 16:10:00 5.7 0.7 7.6 3.8 5.4 0.8 7.6 3.4 237 7 238 305 1.8 0.1 2.2 1.5 10/12/2005 16:20:00 5.9 0.6 7.2 4.2 5.6 0.8 7.6 3.4 241 5 247 305 1.8 0.2 2.2 1.5 10/12/2005 16:30:00 5.2 0.5 6.8 3.4 4.9 0.6 6.5 3.4 242 10 251 305 1.7 0.1 2.2 1.5 10/12/2005 16:40:00 4.2 1 7.2 2.3 3.6 0.8 6.8 1.5 258 8 253 305 1.4 0.1 2 1.3 10/12/2005 16:50:00 5.2 0.5 6.5 3.8 4.6 0.6 6.5 2.6 256 6 267 305 1.7 0.2 2.5 1.5 10/12/2005 17:00:00 4.9 0.8 6.8 2.6 4 0.7 6.1 1.9 261 6 256 305 2.6 0.2 3.2 2.2 10/12/2005 17:10:00 4.5 0.5 6.1 3.4 3.8 0.6 5.3 2.3 262 7 273 305 2.5 0 2.9 2.2 10/12/2005 17:20:00 4.3 0.7 5.7 1.9 3.4 0.6 4.9 1.5 265 6 269 305 2.5 0 2.9 2.2 10/12/2005 17:30:00 4 0.6 5.3 2.3 3.2 0.6 4.6 1.9 267 7 268 305 2.3 0.1 2.7 2.2 10/12/2005 17:40:00 4.3 0.6 5.3 2.6 3.5 0.7 5.3 1.9 263 6 265 305 2.3 0.1 2.7 2.2 10/12/2005 17:50:00 4.5 0.4 5.3 3 3.8 0.6 5.3 2.3 274 8 261 305 2.2 0 2.5 2.2 10/12/2005 18:00:00 4.4 0.5 5.7 2.6 3.6 0.6 4.9 2.3 270 8 283 305 2.1 0 2.2 2 10/12/2005 18:10:00 3.5 0.5 4.6 1.9 2.8 0.6 4.2 1.5 271 9 281 305 2.1 0 2.2 2 10/12/2005 18:20:00 3.6 0.5 4.6 2.6 2.8 0.6 4.2 1.5 271 7 266 305 2 0 2.2 1.7 10/12/2005 18:30:00 4.1 0.5 5.3 2.6 3.4 0.6 4.9 1.9 274 8 279 305 1.5 0.1 2 1.3 10/12/2005 18:40:00 4.5 0.5 5.7 3 3.7 0.6 4.9 2.3 274 6 270 305 1.3 0 1.5 1.3 10/12/2005 18:50:00 4.2 0.4 5.3 3.4 3.6 0.6 4.9 2.3 275 5 279 305 1.3 0.1 1.7 1 10/12/2005 19:00:00 4.4 0.6 6.1 3 3.9 0.5 5.3 2.6 279 5 284 305 1.4 0.1 2 1.3 10/12/2005 19:10:00 4.9 0.5 6.5 3.8 4.2 0.6 6.1 2.6 279 9 283 305 1.4 0 2 1.3 10/12/2005 19:20:00 4.2 0.5 6.1 2.6 3.6 0.5 4.9 2.3 278 8 270 305 1.5 0 2 1.3 10/12/2005 19:30:00 4.7 0.5 6.1 3 4.1 0.6 5.7 2.6 277 4 278 305 1.6 0 2 1.5 10/12/2005 19:40:00 4.8 0.8 6.8 3 4.2 1.1 6.8 2.3 280 12 293 305 1.6 0 2 1.5 10/12/2005 19:50:00 5.9 0.9 7.6 3.8 5.5 0.9 7.2 3.8 294 17 285 305 1.5 0 2.2 1.3 10/12/2005 20:00:00 5.7 0.7 7.6 3.8 5.1 0.8 6.8 2.6 282 8 272 305 1.6 0 2.2 1.5 10/12/2005 20:10:00 5.3 0.8 7.2 3 4.6 0.9 6.5 2.3 280 9 281 305 1.6 0.1 2.2 1.5 10/12/2005 20:20:00 5.7 0.5 6.8 4.2 5.2 0.7 6.5 3.4 279 5 286 305 1.7 0.1 2.2 1.5 10/12/2005 20:30:00 6 0.8 7.6 4.2 5.3 1 7.2 3 280 7 287 305 1.7 0.1 2.2 1.5 10/12/2005 20:40:00 6.4 0.6 8 4.2 5.7 0.8 7.2 3.4 281 6 281 305 1.6 0.1 2 1.5 10/12/2005 20:50:00 5.6 0.6 6.8 3.8 5.1 0.6 6.5 3.4 279 7 283 305 1.4 0.2 2 1.3 10/12/2005 21:00:00 5.1 0.8 6.8 3.4 4.5 0.6 6.1 2.6 282 9 273 305 1.3 0.2 1.7 1 10/12/2005 21:10:00 5.8 0.6 7.2 3.8 4.8 0.7 6.8 3.4 272 6 273 305 1.3 0.2 1.7 1 10/12/2005 21:20:00 5.4 0.8 6.8 3 4.3 0.8 6.5 2.3 265 7 256 305 1.3 0.2 1.7 1 10/12/2005 21:30:00 4.4 0.7 6.5 3 3.5 0.6 5.7 1.9 265 7 254 305 1.3 0.1 1.5 1.3 10/12/2005 21:40:00 5.5 0.8 6.8 3.4 4.4 0.9 6.1 2.3 266 6 266 305 1.3 0.1 1.7 1.3 10/12/2005 21:50:00 5.6 0.6 6.8 3.8 4.8 0.8 6.8 3 258 8 252 305 1.5 0 2 1.3 10/12/2005 22:00:00 5.9 0.7 7.6 3.8 5 0.8 7.2 3 270 8 290 305 1.4 0 1.7 1.3 10/12/2005 22:10:00 5 0.8 6.8 2.6 4.1 0.7 6.5 2.6 265 6 264 305 1.4 0 2 1.3 10/12/2005 22:20:00 5.7 0.8 8.4 3.8 5 1 8.4 2.3 257 7 248 305 1.5 0 2 1.3 10/12/2005 22:30:00 5.5 0.7 7.2 3.4 4.7 0.8 6.8 2.3 258 11 260 305 1.5 0 2 1.3 10/12/2005 22:40:00 5.2 0.6 6.8 3.4 4.6 0.8 6.1 3 253 6 242 305 1.5 0 2 1.3 10/12/2005 22:50:00 5.4 0.7 6.8 3.4 4.6 1 6.8 2.6 259 7 254 305 1.6 0 2 1.5 10/12/2005 23:00:00 5.4 0.6 6.8 4.2 4.4 0.6 6.1 2.6 267 5 271 305 1.6 0 2 1.5 10/12/2005 23:10:00 4.5 0.7 6.5 3 3.6 0.7 6.1 2.3 263 8 258 305 1.6 0 2 1.5 10/12/2005 23:20:00 4.8 0.6 6.5 3.4 3.9 0.6 5.7 2.6 266 6 268 305 1.6 0.1 2.2 1.5 10/12/2005 23:30:00 3.8 0.5 4.9 2.3 3.1 0.5 4.6 1.9 265 8 254 305 1.6 0 2.2 1.5 10/12/2005 23:40:00 4.4 0.5 6.1 2.6 3.6 0.6 5.3 2.3 263 7 266 305 1.7 0.1 2.2 1.5 10/12/2005 23:50:00 4.3 0.4 5.3 3.4 3.7 0.6 5.3 2.3 262 8 270 305 1.6 0 2.2 1.5 10/13/2005 00:00:00 4.9 0.8 7.6 3 4.4 0.7 6.8 2.6 260 13 272 305 1.6 0.1 2.2 1.5 10/13/2005 00:10:00 4.2 0.7 5.3 1.5 4 0.6 5.7 2.3 282 16 266 305 1.8 0 2.2 1.5 10/13/2005 00:20:00 3.6 0.6 4.9 1.9 3.4 0.6 4.6 1.9 291 9 293 305 1.7 0.1 2.2 1.5 10/13/2005 00:30:00 3.4 0.4 4.6 2.3 3.4 0.4 4.6 2.3 300 6 305 305 1.7 0.1 2.2 1.5 10/13/2005 00:40:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 309 6 305 305 1.6 0 2.2 1.5 10/13/2005 00:50:00 4 0.6 5.3 2.3 4.2 0.6 5.3 2.6 307 8 303 305 1.7 0.1 2.2 1.5 10/13/2005 01:00:00 3.8 0.4 4.9 3 4.1 0.4 5.3 3 313 7 319 305 2 0 2.5 2 10/13/2005 01:10:00 2.9 0.5 4.2 2.3 3.1 0.4 4.2 2.3 311 5 306 305 2 0 2.5 2 10/13/2005 01:20:00 3.1 0.5 4.2 1.9 3.2 0.5 4.6 2.3 310 10 305 305 1.9 0 2.5 1.7 10/13/2005 01:30:00 3.1 0.8 4.9 1.5 3.3 0.9 5.3 1.5 327 15 344 305 1.8 0.1 2.2 1.5 10/13/2005 01:40:00 3.9 0.5 5.3 3 4.4 0.5 5.7 3.4 337 7 334 305 1.9 0 2.5 1.7 10/13/2005 01:50:00 4.1 0.6 5.7 2.6 4.5 0.8 6.5 3 347 5 345 305 2 0 2.5 2 10/13/2005 02:00:00 3.9 0.4 4.9 3 4.4 0.4 5.7 3.4 354 4 357 305 1.9 0 2.5 1.7 10/13/2005 02:10:00 3.4 0.5 4.6 2.3 3.7 0.5 4.9 2.6 352 4 356 305 1.9 0 2.5 2 10/13/2005 02:20:00 3.6 0.4 4.6 2.6 4 0.4 4.9 3 344 8 343 305 1.8 0.1 2.2 1.5 10/13/2005 02:30:00 3.9 0.4 4.9 3 4.4 0.4 5.3 3 347 3 345 305 1.8 0.1 2.2 1.5 10/13/2005 02:40:00 3.9 0.5 4.9 2.6 4.3 0.5 5.3 3 338 6 336 305 1.6 0.1 2.2 1.5 10/13/2005 02:50:00 3.8 0.4 5.3 3 4.3 0.4 5.7 3.4 340 6 346 305 1.6 0 2.2 1.5 10/13/2005 03:00:00 3.9 0.4 4.6 3 4.4 0.4 5.3 3.4 344 7 348 305 1.6 0 2.2 1.5 10/13/2005 03:10:00 3.7 0.4 4.6 2.6 4 0.4 4.6 2.6 345 5 344 305 1.6 0.1 2.2 1.3 10/13/2005 03:20:00 3.9 0.5 5.3 2.6 4.3 0.5 5.3 3 341 4 342 305 1.4 0.1 2 1.3 10/13/2005 03:30:00 3.8 0.4 4.9 3 4.2 0.4 5.3 3.4 347 4 340 305 1.5 0.2 2.2 1.3 10/13/2005 03:40:00 3.7 0.4 4.6 2.6 4.2 0.5 5.3 3 342 6 345 305 1.3 0.1 2 1 10/13/2005 03:50:00 4 0.4 4.9 3 4.5 0.5 5.7 3.4 345 8 345 305 1.3 0.1 2 1 10/13/2005 04:00:00 3.5 0.4 4.9 2.6 4 0.4 4.9 3 352 5 353 305 1.4 0 2 1.3 10/13/2005 04:10:00 4 0.6 5.3 3 4.5 0.6 6.1 3.4 350 8 353 305 1.3 0 2 1.3 10/13/2005 04:20:00 3.8 0.5 4.9 2.6 4.2 0.5 5.7 2.6 336 8 341 305 1.2 0.1 1.5 1 10/13/2005 04:30:00 3.4 1 5.3 1.5 3.8 1 5.7 1.9 340 6 336 305 1.3 0 2 1 10/13/2005 04:40:00 3.7 0.4 4.9 3 4 0.5 5.7 2.6 325 11 329 305 1.1 0.1 2 1 10/13/2005 04:50:00 3.6 0.7 4.9 1.9 4 0.7 5.3 2.6 344 6 336 305 1.2 0.1 1.5 1 10/13/2005 05:00:00 3.3 0.4 4.6 2.3 3.6 0.5 4.9 2.6 331 10 352 305 1.2 0.1 1.7 1 10/13/2005 05:10:00 3.5 0.6 4.9 2.6 3.8 0.6 5.3 2.6 357 8 3 305 1.4 0 2 1.3 10/13/2005 05:20:00 2.6 0.6 4.2 1.1 2.9 0.6 4.6 1.9 2 10 3 305 1.5 0 2 1.3 10/13/2005 05:30:00 3.9 1 5.7 1.5 4.4 1 5.7 2.3 337 8 333 305 1.5 0 2 1.3 10/13/2005 05:40:00 2.1 0.8 4.2 0.7 2.6 0.8 4.6 1.1 342 8 352 305 1.6 0 2.2 1.5 10/13/2005 05:50:00 2.2 0.5 3 1.1 2.5 0.5 3.8 1.5 352 9 351 305 1.4 0.1 2 1.3 10/13/2005 06:00:00 2.7 0.6 3.8 1.1 3.1 0.6 4.2 1.9 339 11 333 305 1.5 0 2 1.3 10/13/2005 06:10:00 3.5 1 4.9 1.5 3.9 1 5.7 2.3 327 9 320 305 1.6 0 2 1.3 10/13/2005 06:20:00 4 0.8 5.7 2.6 4.5 0.9 6.5 2.6 335 10 326 305 1.6 0.1 2.2 1.3 10/13/2005 06:30:00 2.3 0.8 4.6 0.4 2.8 0.8 4.9 1.1 343 17 3 305 1.6 0 2.2 1.5 10/13/2005 06:40:00 3.9 0.5 5.3 2.6 4.3 0.5 5.3 2.6 321 5 320 305 1.4 0.1 2 1.3 10/13/2005 06:50:00 2.5 0.7 4.6 0.7 2.9 0.7 5.7 1.5 323 12 316 305 1.6 0.1 2.2 1.3 10/13/2005 07:00:00 3.3 0.9 5.3 1.9 3.7 0.9 5.7 2.3 336 8 339 305 1.6 0 2 1.3 10/13/2005 07:10:00 4.1 0.5 5.3 2.6 4.6 0.5 5.7 3 347 5 344 305 1.6 0.1 2.2 1.3 10/13/2005 07:20:00 4.3 0.5 5.3 3 4.8 0.5 6.1 3.4 0 7 1 305 1.6 0.1 2.2 1.5 10/13/2005 07:30:00 3.1 0.9 4.9 1.5 3.5 0.9 4.9 1.9 356 9 4 305 1.6 0 2.2 1.5 10/13/2005 07:40:00 2.3 0.8 3.8 0.4 2.6 0.6 4.2 1.5 317 8 311 305 1.5 0 2 1.3 10/13/2005 07:50:00 0.5 0.5 2.6 0.4 1.3 0.4 3 0.7 311 10 318 305 1.6 0 2 1.3 10/13/2005 08:00:00 0.7 0.6 2.6 0.4 1.3 0.5 2.6 0.4 308 6 317 305 1.4 0.2 2 1.3 10/13/2005 08:10:00 1.3 1 4.6 0.4 1.8 0.7 4.6 0.7 316 10 306 305 1.2 0.1 1.5 1 10/13/2005 08:20:00 3.6 0.5 4.9 2.6 4 0.4 4.9 3 333 6 331 305 1.3 0.1 2 1 10/13/2005 08:30:00 2.4 0.5 3.8 1.1 2.8 0.5 4.2 1.9 345 7 351 305 1.6 0 2 1.5 10/13/2005 08:40:00 2 0.8 3.4 0.7 2.5 0.5 3.4 1.5 323 13 311 305 1.6 0 2.2 1.3 10/13/2005 08:50:00 1.3 0.5 2.6 0.4 2 0.3 3 1.1 312 6 312 305 1.5 0 2 1.3 10/13/2005 09:00:00 1.9 0.6 3 0.7 2.3 0.5 3.4 1.1 331 12 338 305 1.6 0.1 2.2 1.3 10/13/2005 09:10:00 2.5 0.6 3.4 1.1 2.9 0.5 3.8 1.9 327 5 335 305 1.6 0 2.2 1.5 10/13/2005 09:20:00 2 0.5 3 1.1 2.3 0.4 3 1.5 308 6 305 305 1.6 0 2.2 1.5 10/13/2005 09:30:00 1.8 0.9 3.4 0.4 2.3 0.7 3.8 1.1 319 12 332 305 1.6 0 2.2 1.5 10/13/2005 09:40:00 2.9 0.3 3.4 1.9 3.3 0.4 3.8 2.3 335 9 340 305 1.7 0.1 2.2 1.5 10/13/2005 09:50:00 2.7 0.4 4.2 1.9 3 0.4 4.2 2.3 312 6 321 305 1.7 0.2 2.2 1.5 10/13/2005 10:00:00 2.6 0.4 3.8 1.5 2.9 0.4 4.2 2.3 314 9 336 305 1.8 0.1 2.2 1.5 10/13/2005 10:10:00 2.9 0.6 4.2 1.1 3.1 0.5 4.2 1.5 317 9 320 305 1.8 0.1 2.2 1.5 10/13/2005 10:20:00 3.2 0.3 4.2 2.6 3.4 0.3 4.2 2.6 318 7 317 305 1.9 0.1 2.2 1.7 10/13/2005 10:30:00 3.3 0.3 4.2 2.3 3.5 0.3 4.6 2.6 326 8 326 305 1.9 0.1 2.5 1.7 10/13/2005 10:40:00 3.5 0.5 5.3 2.3 3.8 0.6 5.7 2.3 324 10 333 305 1.9 0 2.5 2 10/13/2005 10:50:00 3.8 0.3 4.6 3 4.2 0.4 4.9 3.4 342 6 345 305 2 0 2.5 2 10/13/2005 11:00:00 4.3 0.5 5.3 3.4 4.8 0.5 6.1 3.8 344 7 345 305 2.1 0.1 2.7 2 10/13/2005 11:10:00 4.9 0.3 5.7 4.2 5.3 0.4 6.1 4.2 342 5 344 305 2.1 0 2.5 2 10/13/2005 11:20:00 4.5 0.4 6.1 3.8 5 0.5 6.5 3.8 342 4 343 305 2 0 2.5 2 10/13/2005 11:30:00 5.1 0.4 6.5 4.2 5.6 0.4 6.5 4.6 349 4 346 305 2 0 2.5 2 10/13/2005 11:40:00 5 0.4 6.1 3.8 5.5 0.5 6.8 4.2 343 6 342 305 2 0 2.5 2 10/13/2005 11:50:00 4.1 0.5 5.3 3 4.6 0.6 6.1 3.4 343 7 348 305 1.9 0.1 2.5 1.7 10/13/2005 12:00:00 4.1 0.5 5.7 3.4 4.6 0.5 6.1 3.4 348 6 341 305 2 0.1 2.5 1.7 10/13/2005 12:10:00 4 0.5 5.7 3 4.4 0.5 5.7 3.4 335 6 348 305 2.1 0 2.7 2 10/13/2005 12:20:00 5.1 1.1 6.8 3 5.6 1.2 7.2 3.4 347 12 351 305 2 0.1 2.5 1.7 10/13/2005 12:30:00 4.5 0.6 6.1 3.4 4.9 0.8 7.2 3.4 9 7 352 305 1.6 0 2.2 1.5 10/13/2005 12:40:00 5 1.1 7.2 3 5.5 1.2 8 3 350 11 347 305 1.7 0.1 2.2 1.3 10/13/2005 12:50:00 4.6 0.8 6.5 3 4.9 1 6.8 3 350 6 355 305 1.5 0.1 2.2 1.3 10/13/2005 13:00:00 4.9 0.4 6.1 3.8 5.4 0.4 6.5 4.2 350 6 352 305 1.7 0.1 2.2 1.5 10/13/2005 13:10:00 4.7 0.4 5.7 3.8 5.2 0.4 6.5 4.2 347 4 344 305 2.2 0.2 2.9 1.7 10/13/2005 13:20:00 4.1 0.5 5.7 3 4.6 0.5 6.1 3.4 337 5 334 305 2.5 0 2.9 2.2 10/13/2005 13:30:00 4.3 0.6 6.1 3 4.7 0.6 6.5 3.4 339 11 2 305 2.5 0.3 3.2 2 10/13/2005 13:40:00 4.4 0.9 6.5 2.6 4.8 1 6.8 3 321 8 333 305 1.5 0.3 2.2 1 10/13/2005 13:50:00 3.9 0.8 5.7 2.3 4.3 0.7 5.7 2.6 312 6 306 305 0.9 0 1.5 0.8 10/13/2005 14:00:00 2.4 0.5 3.4 1.5 2.6 0.4 3.8 1.5 312 5 310 305 0.9 0.1 1.3 0.6 10/13/2005 14:10:00 3.3 0.9 4.6 0.4 3.4 1 4.9 1.5 333 13 333 305 1.3 0.3 2.2 1 10/13/2005 14:20:00 4.3 0.4 5.3 3 4.8 0.5 6.1 3.8 348 5 354 305 2.5 0.2 3.2 2 10/13/2005 14:30:00 4.2 0.3 4.9 3.4 4.7 0.3 5.3 3.8 357 6 3 305 2.5 0.1 3.2 2.2 10/13/2005 14:40:00 3.9 0.4 4.6 3 4.3 0.4 4.9 3 347 6 4 305 2.6 0.1 3.2 2.2 10/13/2005 14:50:00 4.5 0.8 6.1 3 4.9 0.8 6.5 3.4 352 7 351 305 2.4 0.1 2.9 2.2 10/13/2005 15:00:00 4.8 0.4 5.7 3.8 5.3 0.5 6.5 4.2 350 3 347 305 2 0.2 2.7 1.7 10/13/2005 15:10:00 4.7 0.5 5.7 3.4 5.2 0.5 6.5 3.8 352 4 354 305 2 0 2.5 1.7 10/13/2005 15:20:00 4.9 0.4 6.1 3.8 5.4 0.4 6.5 4.6 352 5 352 305 2 0.1 2.5 2 10/13/2005 15:30:00 5.6 0.5 6.8 4.2 6 0.5 7.2 4.6 358 5 356 305 2.5 0 2.9 2.2 10/13/2005 15:40:00 4.8 0.5 6.1 3 5.2 0.6 6.5 3 359 5 359 305 2.6 0.2 3.2 2.2 10/13/2005 15:50:00 5.1 0.5 6.1 4.2 5.5 0.5 6.8 4.6 350 4 355 305 2.6 0.2 3.2 2.2 10/13/2005 16:00:00 5 0.5 6.5 4.2 5.5 0.5 6.8 4.6 355 5 355 305 2.2 0.1 2.7 2 10/13/2005 16:10:00 5.1 0.6 6.5 3.4 5.4 0.7 6.8 3.8 357 4 357 305 2.6 0.1 3.2 2.2 10/13/2005 16:20:00 5.6 0.4 6.5 4.6 6 0.4 7.2 4.6 357 6 353 305 2.8 0.2 3.2 2.5 10/13/2005 16:30:00 5.7 0.5 7.2 4.6 6.1 0.6 7.2 4.6 0 4 359 305 2.6 0.1 3.2 2.5 10/13/2005 16:40:00 6.1 0.5 7.2 4.9 6.5 0.5 8 5.3 2 5 3 305 2.6 0.1 3.2 2.5 10/13/2005 16:50:00 5.7 0.4 6.5 4.6 6.1 0.4 7.2 4.9 2 4 8 305 2.7 0.1 3.2 2.5 10/13/2005 17:00:00 6.9 1.5 9.1 4.2 7.3 1.4 9.5 4.6 352 9 343 305 2.5 0.2 2.9 1.7 10/13/2005 17:10:00 7.3 0.9 9.1 5.3 7.5 0.9 9.1 5.7 344 3 340 305 1.6 0.1 2.2 1.5 10/13/2005 17:20:00 6.5 1.4 10.7 4.6 6.8 1.3 10.7 4.9 355 9 12 305 2 0.4 2.9 1.5 10/13/2005 17:30:00 7.9 1.3 11.1 4.6 8.2 1.3 11.1 4.6 3 9 10 305 1.3 0.4 2.5 1 10/13/2005 17:40:00 5.8 0.9 7.6 4.2 6.1 0.9 8 4.2 346 6 341 305 1.3 0.2 2 1 10/13/2005 17:50:00 7.7 1.3 10.3 4.2 7.9 1.4 10.7 4.6 17 13 25 305 1.9 0.1 2.2 1.5 10/13/2005 18:00:00 7.8 0.6 9.1 6.1 8 0.7 9.5 5.7 24 5 34 305 1.9 0.1 2.2 1.7 10/13/2005 18:10:00 7.5 0.5 9.1 6.1 7.8 0.6 9.5 6.5 13 4 15 305 1.9 0.1 2.5 1.7 10/13/2005 18:20:00 6.9 0.8 8.8 4.9 7.2 0.8 9.1 4.9 15 5 12 305 2 0 2.5 1.7 10/13/2005 18:30:00 7.3 0.7 8.8 5.3 7.6 0.7 9.1 6.1 10 4 16 305 2 0 2.5 2 10/13/2005 18:40:00 8.5 1.2 10.3 5.7 8.8 1.1 10.7 6.5 13 3 11 305 1.9 0.2 2.5 1.5 10/13/2005 18:50:00 7.1 0.6 8.4 5.7 7.3 0.6 8.8 5.3 19 9 13 305 1.8 0.1 2.2 1.5 10/13/2005 19:00:00 6.6 0.5 8 5.3 6.8 0.5 8 5.3 24 10 11 305 1.7 0.1 2.2 1.5 10/13/2005 19:10:00 7.2 0.6 8.8 5.3 7.5 0.7 9.1 5.7 9 4 7 305 2 0.1 2.5 2 10/13/2005 19:20:00 7.5 0.6 9.1 5.3 7.7 0.6 9.5 6.1 17 5 11 305 2.2 0.1 2.5 2 10/13/2005 19:30:00 8 0.8 9.9 6.5 8.2 0.8 9.9 6.5 21 5 25 305 2.2 0 2.7 2 10/13/2005 19:40:00 6.6 0.6 9.1 5.3 6.9 0.6 8.8 5.3 17 6 4 305 2.1 0 2.5 2 10/13/2005 19:50:00 7.9 0.8 9.5 6.5 8.1 0.8 9.9 6.5 12 5 10 305 2.1 0 2.5 2 10/13/2005 20:00:00 7.3 0.6 9.1 5.7 7.5 0.6 9.1 5.7 21 4 28 305 2.1 0 2.5 2 10/13/2005 20:10:00 6.8 0.7 8.4 5.3 7.2 0.7 8.8 5.7 26 4 29 305 2.2 0 2.5 2 10/13/2005 20:20:00 7.1 0.5 8.4 5.7 7.5 0.5 8.8 6.5 18 4 17 305 2.2 0.1 2.7 2.2 10/13/2005 20:30:00 7.6 0.9 9.9 5.7 7.9 0.8 9.9 5.7 8 11 7 305 2.3 0.1 2.7 2.2 10/13/2005 20:40:00 9.1 0.7 11.1 7.2 9.4 0.8 11.8 7.2 359 4 1 305 2 0.2 2.7 1.5 10/13/2005 20:50:00 7.2 2 11.1 3.8 7.6 2.2 11.5 3.8 9 8 356 305 1.2 0.1 2 0.8 10/13/2005 21:00:00 4.9 0.9 7.2 3 5 0.8 7.6 3.4 14 10 10 305 1.2 0.2 2 1 10/13/2005 21:10:00 7.2 0.5 8.4 6.1 7.5 0.5 8.8 6.1 353 4 349 305 1.8 0.2 2.2 1.5 10/13/2005 21:20:00 8.9 1 11.5 7.2 9.2 1 12.2 6.8 4 8 16 305 1.8 0.3 2.5 1.3 10/13/2005 21:30:00 8.2 1.5 10.7 5.3 8.5 1.5 11.1 5.3 4 5 8 305 0.9 0.2 1.5 0.6 10/13/2005 21:40:00 5.7 0.5 7.2 4.2 6 0.5 7.6 4.9 356 5 356 305 1.1 0.2 2 0.8 10/13/2005 21:50:00 7.4 0.7 8.8 5.3 7.7 0.7 8.8 5.3 14 6 20 305 1.7 0.2 2.5 1.3 10/13/2005 22:00:00 8.3 1.1 11.1 6.8 8.6 1.1 11.5 6.5 9 5 7 305 1.8 0.1 2.2 1.5 10/13/2005 22:10:00 7 1.2 9.5 4.9 7.3 1.1 9.9 5.3 7 7 20 305 1.1 0.1 1.5 1 10/13/2005 22:20:00 8 0.8 9.9 6.5 8.2 0.8 10.3 6.8 17 4 20 305 1.6 0.2 2.5 1 10/13/2005 22:30:00 8.4 1 10.7 6.5 8.7 1 10.7 6.5 9 5 0 305 2 0.1 2.7 1.5 10/13/2005 22:40:00 7.4 0.9 10.3 5.7 7.6 1 11.1 5.7 11 8 1 305 1.8 0.2 2.5 1.5 10/13/2005 22:50:00 9 1.2 11.1 6.5 9.3 1.3 11.8 6.8 15 8 10 305 2 0.2 2.7 1.3 10/13/2005 23:00:00 7.4 1.5 11.1 5.3 7.7 1.5 11.5 5.3 4 3 3 305 1.4 0 2 1.3 10/13/2005 23:10:00 6.1 0.5 7.6 4.6 6.3 0.5 7.2 4.9 9 5 2 305 1.6 0.1 2.2 1.3 10/13/2005 23:20:00 7.9 0.8 9.1 5.3 8.1 0.7 9.5 6.1 17 4 18 305 2 0 2.5 1.7 10/13/2005 23:30:00 7.8 0.8 9.5 6.1 8 0.8 9.5 6.1 19 4 22 305 2.2 0.1 2.7 2 10/13/2005 23:40:00 8 0.6 9.5 6.1 8.4 0.6 10.3 6.8 14 9 25 305 2.1 0 2.7 2 10/13/2005 23:50:00 6.4 1.1 8.8 4.2 6.8 1.1 9.1 4.6 357 5 352 305 1.7 0.1 2.5 1.5 10/14/2005 00:00:00 7.6 0.6 8.8 6.1 7.9 0.7 9.1 6.5 356 4 349 305 1.7 0.2 2.2 1.5 10/14/2005 00:10:00 7 0.6 8.8 5.3 7.3 0.7 9.1 5.3 358 5 357 305 1.9 0.1 2.5 1.5 10/14/2005 00:20:00 7.8 0.9 9.1 5.3 8.1 1 9.9 5.7 7 8 357 305 2 0.1 2.7 1.7 10/14/2005 00:30:00 8.4 0.5 9.1 6.8 8.7 0.5 9.9 7.6 353 4 355 305 1.7 0.1 2.2 1.5 10/14/2005 00:40:00 6.3 1 9.5 4.6 6.7 1 9.5 5.3 350 4 354 305 1.3 0.1 2 1.3 10/14/2005 00:50:00 6.8 1 9.1 4.2 7.1 1.1 9.9 4.6 1 5 6 305 1.6 0.1 2.2 1.3 10/14/2005 01:00:00 8.5 1.5 11.5 4.9 8.7 1.5 11.5 5.7 5 7 11 305 1.8 0.2 2.5 1.5 10/14/2005 01:10:00 8.4 1.2 11.1 6.1 8.8 1.2 11.5 6.1 356 9 1 305 1.3 0.2 2.2 1 10/14/2005 01:20:00 5.5 1.2 7.6 3.4 5.9 1.2 8.4 4.2 5 11 351 305 1.3 0.2 2 1 10/14/2005 01:30:00 7.6 0.6 8.8 5.3 7.9 0.6 9.1 5.3 357 5 4 305 1.7 0.2 2.2 1.5 10/14/2005 01:40:00 6.5 1.1 8.4 4.2 6.9 1.1 8.8 4.6 352 12 350 305 1.5 0 2.2 1.3 10/14/2005 01:50:00 6.1 1.2 8.4 4.2 6.5 1.3 8.8 4.6 7 11 352 305 1.8 0.1 2.5 1.5 10/14/2005 02:00:00 7.4 0.7 9.1 5.7 7.7 0.7 9.5 6.1 357 9 5 305 1.6 0.1 2.5 1.3 10/14/2005 02:10:00 6.3 1.5 10.3 4.6 6.6 1.5 11.1 4.6 8 7 5 305 1.5 0.2 2.2 1.3 10/14/2005 02:20:00 7.7 0.8 9.5 5.7 8 0.9 9.9 6.1 359 3 0 305 1.4 0 2 1.3 10/14/2005 02:30:00 7.5 1.2 9.9 4.9 7.9 1.3 10.3 5.7 353 7 0 305 1.4 0 2 1.3 10/14/2005 02:40:00 7.4 1.4 9.9 4.9 7.6 1.4 9.9 3.8 2 7 10 305 1.3 0.1 2 1 10/14/2005 02:50:00 7.5 0.9 9.5 5.3 7.9 1 9.9 5.7 357 3 359 305 1.4 0 2 1.3 10/14/2005 03:00:00 7.5 0.8 9.1 5.7 7.8 0.9 9.5 5.3 359 7 354 305 1.7 0.2 2.2 1.3 10/14/2005 03:10:00 7.2 0.6 9.1 6.1 7.4 0.7 9.5 5.7 15 5 17 305 2 0 2.5 1.7 10/14/2005 03:20:00 7.1 0.6 8.4 5.7 7.4 0.6 8.8 5.7 20 6 15 305 2 0 2.5 2 10/14/2005 03:30:00 6.7 0.7 8.8 5.3 7 0.7 9.1 5.7 12 5 7 305 2 0.1 2.7 2 10/14/2005 03:40:00 7 0.8 8.4 4.9 7.3 0.8 8.8 5.3 5 9 17 305 2.2 0 2.7 2 10/14/2005 03:50:00 6.5 0.7 8.8 4.6 6.9 0.7 9.1 4.9 5 11 0 305 2 0 2.5 2 10/14/2005 04:00:00 6.3 0.6 7.6 4.6 6.6 0.6 8 4.9 20 5 24 305 2.1 0 2.5 2 10/14/2005 04:10:00 7.4 0.6 8.8 5.3 7.7 0.7 9.1 5.7 0 6 355 305 2 0 2.5 2 10/14/2005 04:20:00 7.3 0.6 8.8 6.1 7.7 0.6 9.1 5.7 1 8 358 305 1.9 0.1 2.5 1.7 10/14/2005 04:30:00 5.9 1 8.4 4.6 6.3 1 8.8 4.6 4 5 9 305 1.9 0.2 2.5 1.5 10/14/2005 04:40:00 5.3 0.8 7.6 4.2 5.6 0.7 8 4.2 8 6 5 305 1.6 0.1 2.2 1.3 10/14/2005 04:50:00 6.3 0.7 7.6 4.6 6.6 0.7 8.4 4.9 12 8 2 305 1.9 0.1 2.5 1.5 10/14/2005 05:00:00 6.6 0.6 7.6 4.6 6.9 0.6 8 4.6 20 5 19 305 2.1 0.1 2.7 2 10/14/2005 05:10:00 6.3 0.8 8 4.6 6.6 0.8 8.4 4.9 24 7 33 305 2 0.2 2.5 1.7 10/14/2005 05:20:00 5.6 0.9 8 3.8 5.8 0.9 8.8 4.2 17 5 21 305 1.7 0.2 2.5 1.5 10/14/2005 05:30:00 5.9 0.7 7.2 4.2 6.1 0.8 7.6 4.2 26 4 32 305 2 0.1 2.5 1.7 10/14/2005 05:40:00 6.4 0.6 7.6 5.3 6.7 0.6 8 5.3 20 6 18 305 2.1 0.2 2.7 2 10/14/2005 05:50:00 6 0.9 8.4 4.2 6.2 1 9.1 4.2 29 4 24 305 2.1 0.1 2.5 2 10/14/2005 06:00:00 6.9 0.4 8 5.7 7 0.5 8 5.7 33 5 29 305 1.9 0.2 2.7 1.5 10/14/2005 06:10:00 6.1 0.4 6.8 4.9 6.4 0.5 7.6 5.3 37 3 34 305 1.7 0.2 2.2 1.5 10/14/2005 06:20:00 5.6 0.7 7.2 4.2 5.6 0.7 7.2 4.2 28 7 29 305 1.8 0.1 2.5 1.5 10/14/2005 06:30:00 5.8 0.7 7.6 4.2 5.9 0.7 7.6 4.6 18 4 14 305 1.9 0 2.5 1.7 10/14/2005 06:40:00 5.7 0.7 7.2 4.2 5.8 0.7 7.6 3.8 19 12 7 305 2 0.1 2.5 1.7 10/14/2005 06:50:00 5.3 0.7 7.2 4.2 5.4 0.8 7.6 3.8 21 7 20 305 2 0.1 2.7 2 10/14/2005 07:00:00 5.4 1 8.4 4.2 5.6 1.1 9.1 3.8 14 5 17 305 1.9 0 2.5 2 10/14/2005 07:10:00 5.3 0.6 6.8 3.8 5.4 0.7 7.2 3.8 23 6 19 305 2 0 2.5 2 10/14/2005 07:20:00 4.9 0.8 7.6 3.4 5.2 0.9 8 3.8 28 8 24 305 1.9 0.1 2.5 1.7 10/14/2005 07:30:00 5.3 0.7 7.2 3.8 5.7 0.7 7.2 4.2 17 5 16 305 1.9 0.1 2.5 1.5 10/14/2005 07:40:00 4.9 0.8 6.8 3 5.3 0.8 7.6 3.8 18 5 21 305 1.9 0.1 2.5 1.7 10/14/2005 07:50:00 4.3 0.7 5.7 3 4.7 0.7 6.5 3 20 8 17 305 1.9 0.1 2.5 1.7 10/14/2005 08:00:00 4.4 0.6 5.7 3 4.8 0.6 6.1 3.4 7 7 6 305 1.9 0.1 2.2 1.7 10/14/2005 08:10:00 4.3 0.6 5.7 3 4.6 0.6 6.1 3 17 10 30 305 1.8 0.1 2.2 1.7 10/14/2005 08:20:00 3.9 0.3 4.9 3 4.3 0.4 5.3 3.4 16 6 16 305 1.8 0.1 2.5 1.5 10/14/2005 08:30:00 4.3 0.4 5.3 3.4 4.7 0.4 5.7 3.8 14 5 7 305 1.7 0.1 2.2 1.5 10/14/2005 08:40:00 3.6 0.4 4.6 3 4 0.4 5.3 3 22 5 20 305 1.6 0 2.2 1.5 10/14/2005 08:50:00 3.6 0.3 4.2 3 3.9 0.3 4.6 3 15 4 11 305 1.7 0.1 2.2 1.5 10/14/2005 09:00:00 3.5 0.5 4.9 2.6 3.7 0.6 5.3 2.6 20 6 17 305 1.7 0.1 2.2 1.5 10/14/2005 09:10:00 3.7 0.4 4.6 2.6 3.9 0.5 4.9 2.6 16 10 16 305 1.7 0.1 2.2 1.5 10/14/2005 09:20:00 3.7 0.5 5.3 2.6 3.8 0.5 5.3 3 23 9 11 305 1.8 0.1 2.2 1.5 10/14/2005 09:30:00 3.1 0.4 4.2 1.9 3.4 0.4 4.6 2.6 20 8 38 305 1.9 0 2.5 1.7 10/14/2005 09:40:00 3.5 0.6 4.9 2.3 3.8 0.7 5.3 2.6 33 17 26 305 1.9 0 2.5 1.7 10/14/2005 09:50:00 3.4 0.4 4.6 2.6 3.7 0.4 4.6 2.6 43 11 40 305 1.8 0 2.2 1.7 10/14/2005 10:00:00 3.7 0.7 4.9 2.3 3.9 0.8 5.3 2.3 38 12 22 305 1.9 0 2.5 1.7 10/14/2005 10:10:00 3.3 0.5 4.6 1.9 3.5 0.6 4.9 2.3 31 11 35 305 1.8 0.1 2.5 1.7 10/14/2005 10:20:00 2.5 0.8 4.2 0.7 2.9 0.6 4.6 1.5 9 12 14 305 1.9 0.1 2.5 1.7 10/14/2005 10:30:00 2.1 0.5 3.4 0.4 2.4 0.4 3.4 1.1 24 8 23 305 1.9 0.1 2.5 1.7 10/14/2005 10:40:00 2.8 0.8 4.6 1.1 2.9 0.8 4.9 1.5 20 11 22 305 1.9 0 2.5 2 10/14/2005 10:50:00 0.8 0.5 2.3 0.4 1.4 0.5 2.6 0.4 19 13 16 305 2 0 2.5 2 10/14/2005 11:00:00 1.6 0.8 3.8 0.4 2 0.5 3.4 0.7 39 15 40 305 2.1 0 2.7 2 10/14/2005 11:10:00 0.7 0.5 2.3 0.4 1.2 0.5 2.3 0.4 20 30 10 305 2.2 0.1 2.7 2 10/14/2005 11:20:00 1.6 0.6 2.6 0.4 2.1 0.5 3 0.7 37 17 38 305 2.3 0.1 2.7 2.2 10/14/2005 11:30:00 1.8 0.5 3 0.7 2.2 0.4 3.4 1.1 41 9 47 305 2.2 0.1 2.7 2 10/14/2005 11:40:00 0.9 0.7 2.6 0.4 1.2 0.8 3 0.4 76 15 48 305 2.2 0 2.5 2 10/14/2005 11:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 98 0 305 305 2.2 0 2.7 2 10/14/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 98 0 305 305 2.2 0.1 2.7 2.2 10/14/2005 12:10:00 0.6 0.4 1.9 0.4 1.1 0.6 3 0.4 35 43 359 305 2.3 0.1 2.9 2.2 10/14/2005 12:20:00 0.6 0.4 1.9 0.4 0.9 0.5 2.3 0.4 66 39 76 305 2.5 0.1 3.2 2.2 10/14/2005 12:30:00 1.8 0.5 2.6 0.4 2.2 0.4 3 1.1 105 6 103 305 3.3 0.2 3.7 2.7 10/14/2005 12:40:00 1.1 0.6 2.3 0.4 1.6 0.5 2.6 0.4 96 15 99 305 3.2 0.1 3.7 2.9 10/14/2005 12:50:00 0.4 0 0.7 0.4 0.6 0.3 1.1 0.4 91 22 76 305 3.2 0 3.7 2.9 10/14/2005 13:00:00 1 0.5 2.3 0.4 1.7 0.5 2.6 0.4 16 24 14 305 2.8 0.3 3.7 2.5 10/14/2005 13:10:00 0.9 0.5 2.6 0.4 1.6 0.4 3 0.7 337 13 359 305 2.5 0 2.9 2.5 10/14/2005 13:20:00 0.7 0.5 2.3 0.4 1.3 0.5 3 0.4 346 17 359 305 2.5 0.1 2.9 2.2 10/14/2005 13:30:00 0.4 0.2 1.5 0.4 0.8 0.4 1.9 0.4 241 49 281 305 2.6 0 2.9 2.5 10/14/2005 13:40:00 0.5 0.2 1.5 0.4 1 0.4 1.9 0.4 295 66 312 305 2.7 0.1 3.2 2.5 10/14/2005 13:50:00 1 0.7 2.6 0.4 1.6 0.5 3 0.4 336 24 0 305 2.8 0.1 3.2 2.7 10/14/2005 14:00:00 1.9 0.4 3 0.7 2 0.4 3 1.1 281 12 273 305 2.9 0.1 3.4 2.7 10/14/2005 14:10:00 1.3 0.6 2.6 0.4 1.7 0.4 2.6 0.7 284 28 301 305 2.8 0.1 3.4 2.7 10/14/2005 14:20:00 0.5 0.3 1.5 0.4 1.1 0.4 2.3 0.4 234 28 255 305 2.9 0.1 3.4 2.7 10/14/2005 14:30:00 1.1 0.7 2.6 0.4 1.5 0.7 2.6 0.4 222 26 224 305 3.2 0 3.7 2.9 10/14/2005 14:40:00 1.5 0.5 2.6 0.4 1.7 0.4 3 0.7 246 13 265 305 3.3 0.2 3.7 2.9 10/14/2005 14:50:00 0.9 0.7 3 0.4 1.5 0.5 3 0.4 218 15 226 305 3.5 0.1 3.9 3.2 10/14/2005 15:00:00 0.7 0.4 1.9 0.4 1.2 0.6 2.3 0.4 214 16 245 305 3.8 0.2 4.4 3.4 10/14/2005 15:10:00 1.3 0.7 3 0.4 1.7 0.6 3 0.4 208 33 220 305 3.4 0 3.7 3.2 10/14/2005 15:20:00 1.5 0.4 2.6 0.4 2 0.3 3 1.1 209 11 205 305 3.2 0 3.4 2.9 10/14/2005 15:30:00 1.3 0.4 2.3 0.4 1.7 0.3 2.3 1.1 226 13 219 305 3.2 0 3.4 2.9 10/14/2005 15:40:00 1.4 0.4 2.6 0.4 1.7 0.3 2.6 1.1 229 11 232 305 3.2 0 3.4 3.2 10/14/2005 15:50:00 0.8 0.5 1.9 0.4 1.5 0.3 2.3 0.7 228 11 242 305 3.3 0 3.4 3.2 10/14/2005 16:00:00 1.3 0.6 2.6 0.4 1.6 0.5 3 0.4 223 15 218 305 3.4 0.1 4.2 3.2 10/14/2005 16:10:00 2.1 0.4 3 0.7 2.2 0.3 3 1.1 237 7 245 305 3.3 0.1 3.9 3.2 10/14/2005 16:20:00 2 0.3 2.6 1.1 2.1 0.3 2.6 1.1 233 8 239 305 3.2 0 3.7 3.2 10/14/2005 16:30:00 1.5 0.4 2.3 0.4 1.7 0.3 2.6 0.7 233 10 223 305 3.3 0 3.7 3.2 10/14/2005 16:40:00 1.7 0.4 2.6 0.4 1.8 0.3 2.6 1.1 243 8 239 305 3.2 0 3.7 2.9 10/14/2005 16:50:00 1.6 0.4 2.3 0.4 1.7 0.3 2.3 1.1 240 8 237 305 3.2 0 3.7 2.9 10/14/2005 17:00:00 1.6 0.4 2.6 0.7 1.7 0.3 2.6 0.7 233 6 228 305 3 0.1 3.2 2.7 10/14/2005 17:10:00 1.4 0.3 2.3 0.7 1.6 0.3 2.3 1.1 223 7 218 305 2.8 0.1 3.2 2.7 10/14/2005 17:20:00 1.3 0.4 1.9 0.4 1.5 0.3 2.3 0.7 239 5 231 305 2.7 0 3.2 2.5 10/14/2005 17:30:00 0.5 0.2 1.1 0.4 1 0.3 1.9 0.4 204 17 197 305 3.1 0.1 3.4 2.9 10/14/2005 17:40:00 0.5 0.2 1.1 0.4 1.1 0.2 1.5 0.7 194 1 193 305 3 0.1 3.4 2.9 10/14/2005 17:50:00 0.4 0.1 1.1 0.4 1 0.3 1.5 0.4 180 8 194 305 2.8 0.1 3.4 2.7 10/14/2005 18:00:00 0.8 0.5 1.9 0.4 1.3 0.4 2.3 0.7 162 10 150 305 3.3 0.1 3.7 2.9 10/14/2005 18:10:00 0.7 0.4 1.9 0.4 1 0.5 1.9 0.4 173 15 163 305 3.1 0 3.4 2.9 10/14/2005 18:20:00 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 219 17 218 305 2.8 0.1 3.2 2.7 10/14/2005 18:30:00 1.9 1 3 0.4 1.8 0.9 3 0.4 224 10 224 305 2.5 0.2 2.9 2.2 10/14/2005 18:40:00 2.5 0.3 3.4 1.9 2.6 0.2 3.4 1.9 206 5 198 305 2 0 2.2 2 10/14/2005 18:50:00 2.3 0.2 2.6 1.9 2.6 0.2 3 2.3 196 5 202 305 1.7 0.1 2 1.5 10/14/2005 19:00:00 2.4 0.2 2.6 1.9 2.6 0.2 3 2.3 199 3 200 305 1.6 0 2 1.5 10/14/2005 19:10:00 2.6 0.3 3.4 1.9 2.7 0.2 3 2.3 199 3 204 305 1.8 0.1 2.2 1.5 10/14/2005 19:20:00 2.9 0.2 3.8 2.3 2.9 0.2 3.4 2.3 205 6 208 305 2 0 2.2 1.7 10/14/2005 19:30:00 3.1 0.3 4.2 2.6 3.2 0.3 3.8 2.6 201 6 201 305 1.9 0 2.2 1.7 10/14/2005 19:40:00 3.6 0.4 4.6 2.6 3.7 0.5 4.6 2.6 196 6 196 305 2 0 2.5 1.7 10/14/2005 19:50:00 4.3 0.4 5.3 3.4 4.4 0.5 5.3 3.4 192 6 186 305 2.2 0 2.5 2 10/14/2005 20:00:00 4.8 0.4 6.1 3.8 5.1 0.4 6.1 4.2 193 5 201 305 2.2 0 2.5 2 10/14/2005 20:10:00 5.1 0.4 6.1 4.2 5.1 0.4 6.1 4.2 195 4 198 305 2 0 2.5 2 10/14/2005 20:20:00 5.4 0.3 6.1 4.2 5.4 0.3 6.1 4.2 193 2 194 305 1.9 0.1 2.5 1.5 10/14/2005 20:30:00 5.1 0.4 6.5 4.2 5.1 0.4 6.8 3.8 199 5 206 305 1.8 0.2 2.2 1.5 10/14/2005 20:40:00 5.5 0.5 7.2 4.2 5.5 0.5 6.8 3.8 196 5 198 305 1.9 0.2 2.5 1.5 10/14/2005 20:50:00 5.8 0.5 7.2 4.6 5.8 0.5 6.8 3.8 192 4 196 305 1.7 0.2 2.2 1.5 10/14/2005 21:00:00 5.5 0.5 6.8 4.2 5.5 0.5 6.8 4.2 191 4 197 305 1.7 0.1 2.2 1.5 10/14/2005 21:10:00 5.3 0.6 7.2 3.8 5.3 0.6 6.8 3.8 193 6 190 305 1.6 0 2 1.5 10/14/2005 21:20:00 5.1 0.4 6.5 3.8 5.1 0.5 6.5 3.8 192 5 195 305 1.6 0 2.2 1.5 10/14/2005 21:30:00 5 0.8 7.2 3 5.2 0.6 6.8 4.2 187 5 193 305 1.6 0 2.2 1.5 10/14/2005 21:40:00 5.7 0.5 7.2 4.2 5.7 0.5 7.2 4.2 190 4 190 305 1.5 0 2 1.3 10/14/2005 21:50:00 5.9 0.6 6.8 4.6 5.9 0.6 7.2 4.6 190 3 192 305 1.4 0 2 1.3 10/14/2005 22:00:00 6.3 0.3 6.8 5.3 6.1 0.4 6.8 4.6 193 3 193 305 1.3 0 2 1.3 10/14/2005 22:10:00 6 0.5 6.8 4.9 5.9 0.5 6.8 3.8 192 4 184 305 1.2 0.1 1.5 1 10/14/2005 22:20:00 6.6 0.4 7.6 4.9 6.5 0.5 7.6 4.6 193 3 196 305 1.3 0 2 1.3 10/14/2005 22:30:00 6.3 0.4 7.2 5.3 6.3 0.4 7.6 5.3 191 4 195 305 1.3 0.1 2 1.3 10/14/2005 22:40:00 5.9 0.5 7.2 4.6 5.8 0.5 6.8 4.2 191 3 189 305 1.3 0 2 1.3 10/14/2005 22:50:00 6.1 0.6 7.6 4.2 6.2 0.6 8 4.2 191 5 194 305 1.5 0 2 1.3 10/14/2005 23:00:00 6.1 0.6 8 4.6 6.2 0.6 8 4.9 193 6 191 305 1.4 0.1 2 1.3 10/14/2005 23:10:00 5.7 0.4 6.5 4.6 5.7 0.4 6.8 4.6 190 5 202 305 1.4 0.1 2 1.3 10/14/2005 23:20:00 6.3 0.5 8 4.6 6.5 0.4 7.6 5.3 188 5 188 305 1.5 0.1 2.2 1.3 10/14/2005 23:30:00 6.3 0.7 8.8 3.4 6.6 0.6 9.1 4.9 186 5 188 305 1.6 0.2 2.2 1.3 10/14/2005 23:40:00 6 0.6 7.2 4.2 6.3 0.4 7.6 4.9 185 4 183 305 1.7 0.1 2.2 1.5 10/14/2005 23:50:00 6.2 1 8.8 3 6.8 0.7 8.4 4.6 183 4 194 305 1.7 0.2 2.2 1.5 10/15/2005 00:00:00 6.2 0.8 7.6 3.4 6.7 0.6 8.4 5.3 183 4 188 305 1.8 0.2 2.2 1.5 10/15/2005 00:10:00 6.2 0.7 7.6 3.8 6.7 0.5 8 5.3 184 4 183 305 1.7 0.2 2.2 1.5 10/15/2005 00:20:00 7 0.6 8.4 4.6 7.1 0.5 8.4 4.6 190 4 192 305 1.7 0.2 2.2 1.5 10/15/2005 00:30:00 6.7 0.9 8.4 3.8 7 0.7 8.4 4.9 186 5 183 305 1.6 0 2.2 1.5 10/15/2005 00:40:00 7.2 1 8.8 4.6 7.9 0.6 9.1 5.7 183 4 186 305 1.7 0.1 2.2 1.5 10/15/2005 00:50:00 7.3 0.8 8.4 4.6 7.7 0.5 8.8 6.1 185 4 187 305 1.7 0.1 2.2 1.5 10/15/2005 01:00:00 6.6 1.1 8.8 3.4 7.6 0.7 9.1 5.3 182 5 184 305 1.8 0.2 2.2 1.5 10/15/2005 01:10:00 7.1 1 9.1 4.6 8.1 0.7 9.5 6.1 182 5 180 305 1.9 0.1 2.5 1.5 10/15/2005 01:20:00 7.3 0.9 8.8 4.2 8.1 0.6 9.5 6.1 183 4 182 305 2 0.1 2.5 1.7 10/15/2005 01:30:00 7.3 0.9 9.1 4.6 8.1 0.6 9.5 6.5 183 4 187 305 1.9 0.1 2.2 1.7 10/15/2005 01:40:00 8.1 0.9 10.3 4.2 8.3 0.6 9.9 5.7 187 3 190 305 1.7 0.1 2.5 1.5 10/15/2005 01:50:00 7.6 0.9 9.5 4.6 8 0.6 9.5 6.1 185 4 186 305 1.7 0.1 2.2 1.5 10/15/2005 02:00:00 8.3 0.6 9.9 6.1 8.4 0.6 9.9 6.8 188 3 190 305 1.7 0.1 2.2 1.5 10/15/2005 02:10:00 8.7 0.6 9.9 6.8 8.8 0.6 9.9 6.8 188 2 190 305 1.6 0 2.2 1.5 10/15/2005 02:20:00 8.7 0.4 9.5 7.6 8.8 0.4 9.9 7.6 191 2 190 305 1.6 0 2.2 1.5 10/15/2005 02:30:00 8.5 0.5 9.5 6.5 8.6 0.5 9.9 6.8 189 3 189 305 1.6 0 2.2 1.5 10/15/2005 02:40:00 8.2 0.5 9.1 6.1 8.4 0.5 9.5 6.8 186 2 182 305 1.7 0.1 2.2 1.5 10/15/2005 02:50:00 7.5 1 9.1 4.6 8.3 0.6 9.9 6.5 183 5 184 305 1.9 0 2.5 1.7 10/15/2005 03:00:00 8.4 0.7 9.9 5.7 8.7 0.6 9.9 6.8 187 3 186 305 2 0.1 2.5 2 10/15/2005 03:10:00 9.2 0.5 10.7 7.6 9.3 0.6 10.7 6.8 187 2 190 305 2 0 2.5 2 10/15/2005 03:20:00 9.1 0.4 9.9 8 9.1 0.4 10.3 8 190 2 188 305 2 0 2.5 2 10/15/2005 03:30:00 9 0.4 9.9 7.6 9.2 0.5 10.3 7.6 188 3 190 305 2.1 0 2.5 2 10/15/2005 03:40:00 8.5 0.5 9.5 6.8 9 0.4 9.9 7.6 187 3 190 305 2 0 2.5 2 10/15/2005 03:50:00 8.2 0.5 9.1 6.5 8.6 0.4 9.9 7.6 189 3 194 305 2 0 2.2 2 10/15/2005 04:00:00 8.4 0.7 9.9 6.1 8.6 0.6 10.3 7.2 188 3 190 305 2.1 0 2.5 2 10/15/2005 04:10:00 8.8 0.4 9.5 7.2 9 0.4 9.9 7.6 188 2 191 305 2.2 0 2.5 2 10/15/2005 04:20:00 9.4 0.4 10.7 8 9.5 0.4 10.3 7.6 188 2 186 305 2.3 0.1 2.7 2.2 10/15/2005 04:30:00 8.6 0.8 9.9 5.3 8.9 0.6 10.3 6.5 186 3 188 305 2.2 0.1 2.7 2.2 10/15/2005 04:40:00 8.7 0.7 10.3 6.1 9 0.6 10.7 7.2 186 3 184 305 2.3 0.1 2.7 2.2 10/15/2005 04:50:00 8.7 0.7 10.3 6.5 9.2 0.6 10.3 7.2 185 3 179 305 2.3 0.1 2.7 2.2 10/15/2005 05:00:00 7.9 1 9.9 4.2 8.9 0.6 10.3 6.8 183 4 186 305 2.4 0 2.9 2.2 10/15/2005 05:10:00 8.2 1 9.9 5.3 9.3 0.7 10.7 6.8 182 4 186 305 2.5 0 2.9 2.2 10/15/2005 05:20:00 8.7 1 10.3 4.6 9.6 0.7 11.1 6.8 183 3 188 305 2.4 0 2.9 2.2 10/15/2005 05:30:00 9.3 0.6 10.3 7.2 9.8 0.5 10.7 8 185 3 184 305 2.3 0.1 2.9 2.2 10/15/2005 05:40:00 8 1.2 10.7 4.6 9.3 0.7 11.1 6.5 181 4 194 305 2.5 0 2.9 2.2 10/15/2005 05:50:00 8.3 1 9.9 4.6 9.3 0.7 10.7 6.8 182 4 181 305 2.5 0 2.9 2.5 10/15/2005 06:00:00 8.1 1.3 10.3 4.6 9.3 0.7 10.7 7.2 182 5 188 305 2.6 0 2.9 2.5 10/15/2005 06:10:00 9.2 0.6 9.9 6.5 9.5 0.6 10.7 7.6 186 3 183 305 2.4 0.1 2.9 2.2 10/15/2005 06:20:00 9 0.6 10.3 6.5 9.4 0.5 10.7 8 185 2 188 305 2.3 0.1 2.7 2.2 10/15/2005 06:30:00 8.6 0.8 9.9 4.9 9.2 0.5 10.7 7.2 184 3 188 305 2.3 0.1 2.7 2.2 10/15/2005 06:40:00 8.8 0.7 9.9 6.1 9.3 0.5 10.7 7.2 184 3 186 305 2.3 0.1 2.7 2.2 10/15/2005 06:50:00 8.9 1 11.1 5.7 9.5 0.7 11.1 7.6 185 3 188 305 2.3 0.1 2.9 2.2 10/15/2005 07:00:00 9.6 0.7 10.7 6.1 9.8 0.6 11.1 7.6 186 3 190 305 2.3 0.1 2.7 2.2 10/15/2005 07:10:00 9.6 0.7 11.1 6.1 9.9 0.7 11.1 7.2 186 3 188 305 2.3 0.1 2.7 2.2 10/15/2005 07:20:00 9.4 1 11.1 5.3 10.1 0.6 11.5 7.6 184 3 189 305 2.5 0 2.9 2.2 10/15/2005 07:30:00 9.3 0.9 10.7 6.1 10 0.6 11.1 8.4 184 3 185 305 2.6 0 2.9 2.5 10/15/2005 07:40:00 8.9 1.1 11.1 5.3 10 0.7 11.5 8 182 4 183 305 2.7 0 3.2 2.5 10/15/2005 07:50:00 8.5 1 10.3 4.9 9.8 0.7 11.1 7.2 182 4 184 305 2.7 0 3.2 2.7 10/15/2005 08:00:00 8.4 1.3 11.1 4.6 10 0.9 11.8 7.6 181 5 180 305 2.8 0 3.2 2.7 10/15/2005 08:10:00 7.8 1.4 11.1 4.2 9.5 0.9 11.5 6.1 179 6 186 305 2.8 0.1 3.4 2.7 10/15/2005 08:20:00 8 1.5 11.5 4.6 9.8 1 12.2 6.8 179 5 189 305 2.8 0.1 3.2 2.7 10/15/2005 08:30:00 8.3 1.4 11.1 4.9 10 1 12.2 7.6 180 6 184 305 2.8 0.1 3.2 2.7 10/15/2005 08:40:00 7.8 1.6 11.5 4.6 9.7 0.9 11.8 6.8 179 7 181 305 2.9 0.1 3.4 2.7 10/15/2005 08:50:00 7.6 1.6 11.5 4.2 9.8 1 13 7.6 178 6 181 305 2.9 0.1 3.4 2.7 10/15/2005 09:00:00 8.3 1.5 12.2 4.6 10.2 1 12.6 7.6 180 6 174 305 2.8 0.1 3.2 2.7 10/15/2005 09:10:00 8.3 1.5 11.5 4.6 10.3 1 12.2 7.6 179 5 192 305 2.8 0.1 3.2 2.7 10/15/2005 09:20:00 7.9 1.7 11.5 3.4 9.7 1.1 12.2 6.8 179 6 188 305 2.8 0.1 3.2 2.7 10/15/2005 09:30:00 8.3 1.5 11.5 4.2 9.9 1.1 12.2 7.2 180 6 189 305 2.9 0.1 3.4 2.7 10/15/2005 09:40:00 8.3 1.4 11.1 4.9 10.2 0.9 12.6 6.8 180 5 186 305 2.9 0.1 3.4 2.7 10/15/2005 09:50:00 8.1 1.5 11.1 4.6 10.1 1 12.6 7.2 180 5 182 305 2.9 0 3.2 2.9 10/15/2005 10:00:00 8.1 1.5 11.1 3.8 9.7 1.1 11.8 6.8 180 6 187 305 2.9 0.1 3.4 2.7 10/15/2005 10:10:00 8 1.7 11.5 4.2 9.9 1.2 12.2 7.2 179 6 190 305 2.9 0 3.4 2.9 10/15/2005 10:20:00 7.3 1.5 11.5 4.2 9.1 1 11.5 6.5 179 7 186 305 2.9 0 3.4 2.9 10/15/2005 10:30:00 7.6 1.7 12.2 4.6 9.7 1.1 12.2 6.8 179 6 176 305 3 0 3.4 2.9 10/15/2005 10:40:00 7.3 1.5 11.8 4.6 9.5 1 12.2 6.5 177 7 187 305 2.9 0 3.4 2.9 10/15/2005 10:50:00 7.4 1.5 11.5 4.6 9.7 1 12.2 7.2 177 7 187 305 3 0 3.4 2.9 10/15/2005 11:00:00 7.1 1.2 11.1 4.6 10.3 0.9 13.7 7.6 173 6 194 305 3.1 0 3.7 2.9 10/15/2005 11:10:00 7.2 1.3 11.5 4.9 10 1 12.6 7.2 175 7 186 305 3.1 0 3.7 2.9 10/15/2005 11:20:00 6.9 1.3 10.7 4.2 9.6 1 11.8 7.2 175 7 176 305 3.1 0 3.7 2.9 10/15/2005 11:30:00 6.8 1.3 11.1 4.2 9 1 11.8 6.5 176 7 183 305 3.1 0.1 3.4 2.9 10/15/2005 11:40:00 7.3 1.6 11.5 3.8 9.3 1.2 12.6 6.5 178 6 186 305 3.1 0 3.7 2.9 10/15/2005 11:50:00 7.8 1.2 10.3 4.2 9.9 0.9 12.6 7.2 179 6 180 305 3.1 0.1 3.7 2.9 10/15/2005 12:00:00 7.8 1.2 10.7 5.3 9.6 0.8 12.2 6.8 181 5 176 305 3.1 0 3.7 2.9 10/15/2005 12:10:00 7.6 1.3 10.3 4.6 9.1 1 11.5 6.1 168 23 188 305 3.2 0 3.7 2.9 10/15/2005 12:20:00 7.5 1.3 11.1 4.2 9.4 0.8 11.8 6.8 179 6 182 305 3.3 0.1 3.7 2.9 10/15/2005 12:30:00 7.8 1.2 11.5 4.6 9.8 0.9 11.8 7.2 179 6 179 305 3.3 0.1 3.7 3.2 10/15/2005 12:40:00 8.1 1.2 11.5 4.9 10.1 0.9 12.2 8 180 5 187 305 3.3 0.1 3.7 3.2 10/15/2005 12:50:00 8.2 1.4 11.8 4.9 10.1 1 12.6 8 180 5 183 305 3.4 0.1 3.9 3.2 10/15/2005 13:00:00 8 1.5 11.5 4.2 10.3 1.2 12.6 6.5 179 6 181 305 3.5 0.2 4.2 3.4 10/15/2005 13:10:00 7.9 1.5 12.2 4.9 10.2 1.3 13.7 7.2 178 7 179 305 3.7 0.2 4.2 3.4 10/15/2005 13:20:00 7.3 1.5 11.1 4.6 9.9 1.2 13.3 6.8 175 7 186 305 3.7 0.2 4.2 3.4 10/15/2005 13:30:00 7.2 1.4 11.5 4.6 9.5 1 12.6 6.1 174 8 191 305 3.7 0 4.2 3.4 10/15/2005 13:40:00 7 1.3 10.7 4.6 9.7 1 11.8 7.2 175 7 184 305 3.7 0.1 4.2 3.4 10/15/2005 13:50:00 7.5 1.4 11.8 4.6 9.7 1.1 12.2 6.5 177 7 184 305 3.7 0 4.2 3.4 10/15/2005 14:00:00 6.7 1.3 10.3 4.2 9.4 0.9 12.2 6.8 173 7 183 305 3.7 0 4.2 3.4 10/15/2005 14:10:00 6.9 1.5 11.5 4.2 9.9 1.2 12.6 6.5 173 7 162 305 3.8 0.1 4.4 3.4 10/15/2005 14:20:00 7.3 1.3 10.7 4.2 9.7 1 12.2 6.8 176 7 187 305 3.8 0.1 4.4 3.7 10/15/2005 14:30:00 7.6 1.5 12.6 4.9 9.9 1.1 13.3 7.2 176 7 184 305 3.8 0.1 4.4 3.7 10/15/2005 14:40:00 8 1.7 12.6 4.6 10.4 1.3 13.7 7.2 177 6 186 305 3.8 0.1 4.4 3.7 10/15/2005 14:50:00 8 1.4 11.8 4.9 10.6 1.2 13.7 7.2 173 8 164 305 3.7 0.1 4.2 3.4 10/15/2005 15:00:00 8.6 1.5 13.3 5.7 11.4 1.3 14.9 8.4 172 8 181 305 3.7 0.2 4.2 3.4 10/15/2005 15:10:00 8.9 1.2 13.7 6.1 12.3 1.3 16.1 8.8 171 6 174 305 3.5 0.2 4.2 3.2 10/15/2005 15:20:00 9.3 1.1 13.3 6.5 13.5 1.1 16.4 10.3 170 6 162 305 3.4 0.2 3.7 3.2 10/15/2005 15:30:00 9 1.1 14.1 6.1 13.2 1.2 16.4 9.5 170 5 159 305 3.3 0 3.7 3.2 10/15/2005 15:40:00 9.3 1.2 13.7 6.5 13.5 1.2 16.8 9.1 169 5 163 305 3.1 0 3.7 2.9 10/15/2005 15:50:00 9.5 1.3 13.3 6.5 13.6 1.3 16.8 9.5 169 6 162 305 3.1 0 3.4 2.9 10/15/2005 16:00:00 9 1.3 14.1 6.1 13.2 1.2 15.6 9.9 169 5 162 305 3.2 0 3.4 2.9 10/15/2005 16:10:00 9.6 1.3 14.9 6.8 13.9 1.2 17.2 9.9 169 5 159 305 3.2 0.1 3.4 2.9 10/15/2005 16:20:00 9.2 1.1 12.6 6.5 13.4 1.2 15.6 10.3 169 5 164 305 3.3 0 3.7 3.2 10/15/2005 16:30:00 9.4 1.2 14.5 6.8 13.7 1.1 17.2 11.1 169 5 163 305 3.3 0 3.7 3.2 10/15/2005 16:40:00 9.8 1.4 14.9 7.2 14 1.3 17.6 9.5 169 5 165 305 3.3 0 3.7 3.2 10/15/2005 16:50:00 9.6 1.2 13.7 7.2 13.7 1.3 17.6 9.9 169 5 174 305 3.3 0 3.7 3.2 10/15/2005 17:00:00 9.2 1.2 13.7 6.1 13.2 1.2 16.8 9.9 169 6 159 305 3.3 0 3.7 3.2 10/15/2005 17:10:00 8.8 1.3 13.7 5.7 12.5 1.2 16.1 8.8 168 5 154 305 3.3 0 3.7 3.2 10/15/2005 17:20:00 9.4 1.2 13.7 6.5 13.8 1.4 17.2 10.3 169 5 181 305 3.3 0 3.7 3.2 10/15/2005 17:30:00 9.5 1.3 14.5 6.5 13.5 1.3 17.6 9.5 168 5 156 305 3.3 0 3.7 3.2 10/15/2005 17:40:00 9.7 1.4 14.5 6.5 13.3 1.3 16.4 9.9 168 5 159 305 3.3 0.1 3.7 3.2 10/15/2005 17:50:00 9.2 1.1 13 6.5 13 1.1 16.1 9.5 168 5 160 305 3.4 0.1 3.7 3.2 10/15/2005 18:00:00 10 1.3 15.6 7.2 14.5 1.4 18.3 10.7 169 5 163 305 3.5 0 4.2 3.4 10/15/2005 18:10:00 10 1.3 15.3 6.8 14.1 1.3 16.8 10.3 169 5 174 305 3.5 0 4.2 3.4 10/15/2005 18:20:00 10 1.2 13.3 7.2 14.3 1.3 17.2 10.7 169 5 161 305 3.5 0 4.2 3.4 10/15/2005 18:30:00 10.2 1.3 14.1 7.2 14.3 1.2 17.6 9.9 168 5 161 305 3.6 0 4.2 3.4 10/15/2005 18:40:00 10.1 1.3 14.5 7.6 14 1.2 17.2 10.3 168 5 161 305 3.5 0 3.9 3.4 10/15/2005 18:50:00 9.5 1.3 13.7 6.8 12.9 1.2 16.1 9.9 168 5 156 305 3.5 0 3.9 3.4 10/15/2005 19:00:00 9.8 1.5 14.1 6.5 12.4 1.1 16.1 9.1 166 6 156 305 3.4 0.1 3.9 3.2 10/15/2005 19:10:00 9.8 1.5 14.1 6.5 12.6 1.1 15.6 9.5 166 6 156 305 3.4 0.1 3.9 3.2 10/15/2005 19:20:00 9.4 1.4 13.7 6.5 12.4 1.1 15.6 9.1 167 6 171 305 3.5 0 4.2 3.4 10/15/2005 19:30:00 9.5 1.5 13.7 5.7 12.3 1.1 14.9 9.1 166 6 163 305 3.6 0 4.2 3.4 10/15/2005 19:40:00 9.8 1.3 14.1 6.8 13.3 1.2 16.4 10.3 168 6 174 305 3.8 0.2 4.4 3.4 10/15/2005 19:50:00 10.3 1.3 15.6 6.5 14.1 1.4 17.9 10.7 169 5 152 305 4 0.2 4.4 3.7 10/15/2005 20:00:00 10.4 1.3 15.3 7.6 14.1 1.3 17.2 10.7 169 6 165 305 4 0.1 4.4 3.7 10/15/2005 20:10:00 10.8 1.3 14.5 7.2 14.4 1.3 17.9 10.7 168 6 160 305 4.1 0.1 4.7 3.9 10/15/2005 20:20:00 10.8 1.5 15.6 7.2 14.5 1.4 18.3 10.3 168 6 159 305 4.2 0.1 4.7 4.2 10/15/2005 20:30:00 11.1 1.3 16.1 8 14.7 1.6 18.3 9.5 168 6 172 305 4.4 0.2 4.9 4.2 10/15/2005 20:40:00 12 1.3 15.3 7.6 16.1 1.4 20.6 11.5 169 5 155 305 4.5 0.2 4.9 4.2 10/15/2005 20:50:00 12.3 1.4 16.1 8 16.5 1.5 19.9 12.6 171 6 183 305 4.6 0.2 5.2 4.4 10/15/2005 21:00:00 10.6 1.5 15.6 7.2 14.1 1.7 19.1 8.8 172 7 168 305 4.7 0.1 5.2 4.4 10/15/2005 21:10:00 12.3 1.4 16.4 8 16 1.4 19.1 11.5 170 6 169 305 4.8 0.1 5.4 4.7 10/15/2005 21:20:00 11.6 1.6 17.2 7.6 14.2 1.5 18.7 10.7 173 6 171 305 4.8 0.1 5.4 4.7 10/15/2005 21:30:00 11 1.8 15.3 5.7 12.5 1.3 16.1 8.4 179 6 186 305 4.6 0.1 5.2 4.4 10/15/2005 21:40:00 11.5 1.6 15.6 7.6 13.1 1.1 16.1 10.3 181 6 185 305 4.8 0.1 5.4 4.4 10/15/2005 21:50:00 11.5 1.1 14.1 6.8 12.6 1.1 15.3 9.5 183 6 186 305 4.9 0 5.4 4.7 10/15/2005 22:00:00 11.5 0.9 13.7 9.1 11.3 1 14.1 7.6 188 4 188 305 4.8 0.1 5.4 4.7 10/15/2005 22:10:00 11 1 13.3 8.4 10.7 1 13.3 7.2 191 4 188 305 4.9 0.1 5.4 4.7 10/15/2005 22:20:00 11.6 0.6 13.3 9.9 11 0.8 13.3 8 196 3 197 305 5 0.2 5.4 4.9 10/15/2005 22:30:00 11.1 0.6 13 9.1 10.8 0.7 13 8.8 202 4 198 305 5 0.2 5.6 4.9 10/15/2005 22:40:00 10 0.9 12.6 7.2 9.2 1.1 11.8 6.1 212 5 214 305 5.5 0.1 5.9 5.4 10/15/2005 22:50:00 10.3 0.6 12.2 6.8 9.9 0.7 11.5 6.8 208 4 208 305 5.5 0.1 5.9 5.4 10/15/2005 23:00:00 10.3 0.6 11.5 8.4 9.9 0.6 11.5 7.2 208 3 208 305 5.5 0 5.9 5.4 10/15/2005 23:10:00 10.3 0.6 11.8 8.8 10 0.6 11.5 8 207 3 210 305 5.4 0 5.6 5.2 10/15/2005 23:20:00 9.7 0.5 11.5 7.6 9.4 0.6 11.1 6.5 201 3 208 305 5.2 0.2 5.6 4.9 10/15/2005 23:30:00 10.4 0.9 12.2 8.4 10 0.9 12.2 7.6 203 5 204 305 5 0.2 5.6 4.9 10/15/2005 23:40:00 10.6 1 12.6 6.8 9.7 1.1 12.2 6.5 212 6 213 305 5.4 0 5.9 5.2 10/15/2005 23:50:00 10.9 0.7 12.6 8.8 10.4 0.7 12.2 8.8 218 4 210 305 5.5 0 5.9 5.4 10/16/2005 00:00:00 11.1 1 13.3 8 10.1 1.1 12.6 7.6 223 5 228 305 5.5 0.1 5.9 5.4 10/16/2005 00:10:00 10.7 1.1 14.1 7.6 9.7 1.2 13.3 6.8 224 5 224 305 5.5 0.1 5.9 5.4 10/16/2005 00:20:00 10.3 0.9 12.2 7.2 9.3 1 12.2 6.8 223 5 214 305 5.5 0 5.9 5.4 10/16/2005 00:30:00 10.3 0.9 12.2 8 9.4 1 12.2 6.8 226 5 220 305 5.5 0 5.9 5.4 10/16/2005 00:40:00 10.6 0.9 13 8.4 9.7 1 12.6 7.2 227 5 227 305 5.5 0.1 5.9 5.4 10/16/2005 00:50:00 10.8 0.8 13 8 10 1 11.8 6.8 228 4 231 305 5.6 0.1 5.9 5.4 10/16/2005 01:00:00 10.2 0.9 12.2 7.6 9.2 1 11.5 6.5 227 5 229 305 5.5 0.1 6.1 5.4 10/16/2005 01:10:00 10.2 0.7 11.8 8.4 9.4 0.8 11.5 7.2 230 4 233 305 5.6 0.1 6.1 5.4 10/16/2005 01:20:00 10.1 0.7 12.2 7.6 9.4 0.8 11.1 6.8 229 4 229 305 5.6 0.1 6.1 5.4 10/16/2005 01:30:00 9.4 0.8 11.5 7.2 8.8 0.8 10.7 6.5 231 4 225 305 5.5 0.1 6.1 5.4 10/16/2005 01:40:00 8.9 0.6 10.7 7.2 8.2 0.9 9.9 5.7 228 5 224 305 5.5 0.1 5.9 5.4 10/16/2005 01:50:00 8.6 0.6 10.3 6.5 7.8 0.8 9.5 5.7 226 4 230 305 5.4 0 5.9 5.4 10/16/2005 02:00:00 8.6 0.7 10.3 6.5 7.8 0.8 9.5 5.7 227 5 225 305 5.5 0.1 5.9 5.2 10/16/2005 02:10:00 8.5 0.8 10.7 6.1 7.9 0.8 9.9 6.1 231 6 232 305 5.5 0.1 5.9 5.4 10/16/2005 02:20:00 8.7 0.8 11.1 6.5 8 0.8 10.7 6.1 240 5 245 305 5.5 0.1 6.1 5.4 10/16/2005 02:30:00 8.6 1 10.7 6.1 8 1 10.7 5.3 249 7 252 305 5.6 0.1 6.1 5.4 10/16/2005 02:40:00 7.7 1.5 11.1 4.9 6.4 1.5 10.7 3.4 271 7 275 305 5.5 0.1 6.1 5.2 10/16/2005 02:50:00 6 0.6 7.6 4.2 4.7 0.6 6.8 3.4 265 6 276 305 5.2 0 5.9 4.9 10/16/2005 03:00:00 6.3 1 9.5 3.4 5 0.8 7.2 2.3 270 8 277 305 5.2 0 5.6 4.9 10/16/2005 03:10:00 7.8 1.1 10.3 4.9 6.4 1.1 9.1 3.4 274 7 266 305 5.2 0 5.9 4.9 10/16/2005 03:20:00 8.6 1.1 11.5 5.3 7.2 1.1 10.3 4.9 277 8 280 305 5.2 0.1 5.9 4.9 10/16/2005 03:30:00 9 1.2 11.5 6.1 8.1 1.3 11.1 4.6 285 11 285 305 4.9 0.1 5.6 4.7 10/16/2005 03:40:00 8.7 1 11.1 6.1 8.2 1 10.3 6.1 290 11 294 305 4.9 0 5.4 4.7 10/16/2005 03:50:00 8.3 0.8 10.3 6.5 7.4 0.9 9.5 4.6 284 6 276 305 4.9 0.1 5.4 4.7 10/16/2005 04:00:00 7.9 0.9 9.9 5.3 6.9 1 9.5 4.6 280 6 279 305 4.9 0.1 5.4 4.7 10/16/2005 04:10:00 7.8 1.2 10.7 4.6 6.6 1.1 9.5 3.4 276 6 280 305 5 0.2 5.4 4.9 10/16/2005 04:20:00 7.5 0.9 9.9 5.3 6.4 1 8.8 3.8 274 8 273 305 5 0.2 5.6 4.9 10/16/2005 04:30:00 7.3 0.8 9.5 5.3 5.8 0.8 8.4 3.4 270 7 277 305 5 0.2 5.4 4.9 10/16/2005 04:40:00 8.1 0.9 9.9 4.6 6.4 1 8.8 3.4 267 6 268 305 5.1 0.2 5.4 4.9 10/16/2005 04:50:00 7.6 1.2 10.7 4.6 6.1 1.1 8.4 3.4 268 7 268 305 5.1 0.2 5.4 4.9 10/16/2005 05:00:00 8 1 10.7 5.3 6.3 1.1 9.1 3.4 270 6 261 305 5 0.2 5.4 4.9 10/16/2005 05:10:00 7.9 0.8 9.9 4.9 6.4 1 8.8 4.2 271 6 276 305 5 0.2 5.4 4.9 10/16/2005 05:20:00 6.8 0.7 8.8 4.9 5.4 0.7 8 3.4 267 6 272 305 5 0.2 5.4 4.9 10/16/2005 05:30:00 6.5 0.7 8.4 3.8 5.1 0.7 7.2 3.4 265 7 267 305 5 0.1 5.4 4.9 10/16/2005 05:40:00 6.9 0.8 8.8 3.4 5.5 0.8 8 3 263 7 259 305 5 0.2 5.4 4.7 10/16/2005 05:50:00 6.5 0.6 8.4 4.9 5.2 0.6 7.2 3.8 261 6 267 305 5 0.2 5.4 4.9 10/16/2005 06:00:00 7 0.6 8.4 5.3 5.7 0.7 7.2 3.8 261 5 256 305 5 0.2 5.4 4.9 10/16/2005 06:10:00 6.6 0.6 8.4 4.9 5.5 0.7 8 3.8 259 5 261 305 5 0.1 5.4 4.7 10/16/2005 06:20:00 6.3 0.6 8 4.6 5.5 0.6 7.2 3.8 255 5 258 305 4.9 0.1 5.4 4.7 10/16/2005 06:30:00 5.5 0.6 7.2 3.8 4.8 0.6 6.5 3 254 6 259 305 4.9 0 5.4 4.7 10/16/2005 06:40:00 5.2 0.4 6.5 3.4 4.6 0.5 5.7 3 253 5 243 305 4.8 0 5.4 4.7 10/16/2005 06:50:00 5.2 0.4 6.1 3.8 4.7 0.5 5.7 3 250 5 248 305 4.8 0.1 5.2 4.7 10/16/2005 07:00:00 5.2 0.4 6.1 4.2 4.7 0.5 6.1 3.4 246 5 255 305 4.7 0.1 5.2 4.4 10/16/2005 07:10:00 5.1 0.4 6.1 4.2 4.5 0.5 5.7 3.4 236 5 244 305 4.6 0.1 5.2 4.4 10/16/2005 07:20:00 4.8 0.4 5.7 3.8 4.5 0.5 5.7 3.4 232 3 233 305 4.5 0.1 4.9 4.4 10/16/2005 07:30:00 4.8 0.4 5.7 3.8 4.3 0.4 5.3 3 229 5 234 305 4.5 0.1 4.9 4.4 10/16/2005 07:40:00 4.9 0.3 5.7 3.8 4.5 0.4 5.3 3.4 221 3 223 305 4.4 0.2 4.9 4.4 10/16/2005 07:50:00 4.2 0.4 5.3 3 3.8 0.4 4.6 2.6 216 5 216 305 4.3 0.1 4.9 4.2 10/16/2005 08:00:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 205 7 215 305 4.4 0.2 4.9 4.2 10/16/2005 08:10:00 4.4 0.7 6.5 2.3 4.6 0.9 6.8 2.6 192 9 193 305 4.5 0.2 4.9 4.2 10/16/2005 08:20:00 5.1 0.7 7.6 3.4 5.4 0.8 8 3.8 190 6 188 305 4.4 0.1 4.9 4.2 10/16/2005 08:30:00 5.8 0.5 6.5 4.2 6.1 0.5 6.8 4.6 191 3 192 305 4.2 0.1 4.9 3.9 10/16/2005 08:40:00 6.1 0.3 6.8 5.3 6.4 0.3 7.2 5.3 194 2 194 305 4.2 0 4.7 3.9 10/16/2005 08:50:00 6.7 0.2 7.2 6.1 6.8 0.4 7.6 5.3 197 2 196 305 4.4 0.1 4.9 4.2 10/16/2005 09:00:00 6.7 0.2 7.6 6.1 6.8 0.3 7.6 5.7 196 3 204 305 4.2 0.1 4.7 3.9 10/16/2005 09:10:00 6.9 0.3 7.6 6.1 6.9 0.4 7.6 5.7 195 2 194 305 4.2 0.1 4.7 3.9 10/16/2005 09:20:00 7.3 0.6 8.8 4.9 7.4 0.5 8.8 5.7 195 5 198 305 4.1 0.2 4.7 3.7 10/16/2005 09:30:00 5.9 0.8 7.6 3.4 6.5 0.7 8.4 4.6 189 7 192 305 4 0.2 4.4 3.7 10/16/2005 09:40:00 5.3 0.8 8 3.4 6.4 0.6 8 4.6 183 7 189 305 4.1 0.2 4.7 3.7 10/16/2005 09:50:00 5.2 0.7 7.6 3.4 5.7 0.8 8.4 3.4 187 7 190 305 4.3 0.1 4.9 3.9 10/16/2005 10:00:00 4.9 0.7 7.2 3 5.7 0.6 8.4 4.2 186 6 171 305 4.5 0.2 4.9 4.4 10/16/2005 10:10:00 5.3 0.5 7.2 3.8 5.5 0.5 6.8 4.6 191 5 196 305 4.4 0.1 4.9 4.2 10/16/2005 10:20:00 5.4 0.3 6.1 4.2 5.8 0.3 6.5 5.3 191 3 192 305 4.2 0.1 4.7 4.2 10/16/2005 10:30:00 5.5 0.3 6.5 4.6 5.7 0.4 6.8 4.6 195 4 193 305 4.2 0.1 4.7 3.9 10/16/2005 10:40:00 5.4 0.3 6.1 4.6 5.6 0.3 6.1 4.9 193 3 193 305 4.1 0.1 4.7 3.9 10/16/2005 10:50:00 5.2 0.3 6.1 4.6 5.5 0.3 6.1 4.9 190 2 193 305 4 0.1 4.7 3.9 10/16/2005 11:00:00 5.7 0.3 6.1 4.9 6.1 0.3 6.8 5.3 189 2 190 305 4.2 0.1 4.9 3.9 10/16/2005 11:10:00 5.8 0.7 7.6 2.6 6.5 0.6 7.6 3.8 184 6 186 305 4.4 0.1 4.9 4.2 10/16/2005 11:20:00 5 0.8 6.8 3 5.4 0.9 7.6 3.4 156 13 186 305 4.3 0.3 5.2 3.9 10/16/2005 11:30:00 5.1 1 6.8 1.9 5.5 0.8 7.6 3.8 158 11 149 305 4.1 0.1 4.7 3.9 10/16/2005 11:40:00 5.2 1.4 7.6 2.3 6.1 0.9 8 4.6 177 9 186 305 4.5 0.2 5.4 4.2 10/16/2005 11:50:00 6.8 0.5 7.6 5.3 7.2 0.5 8.4 6.1 187 3 186 305 5 0.1 5.4 4.7 10/16/2005 12:00:00 4 1 6.5 2.6 5.5 0.6 6.8 3.8 176 7 182 305 5.3 0 5.6 4.9 10/16/2005 12:10:00 4.1 0.8 6.5 2.3 5.5 0.7 8 3.8 171 9 181 305 5.4 0 5.9 5.2 10/16/2005 12:20:00 4.5 0.9 7.2 3 6.3 0.6 8 4.6 174 7 158 305 5.5 0.1 5.9 5.4 10/16/2005 12:30:00 5.5 0.9 7.2 3 6.1 0.6 8 4.6 162 6 161 305 5.2 0.2 5.9 4.9 10/16/2005 12:40:00 5.6 0.7 7.2 3.4 5.8 0.6 7.6 4.6 158 6 150 305 5 0.2 5.6 4.9 10/16/2005 12:50:00 6.3 0.7 8 4.6 6.3 0.6 8 4.6 152 6 159 305 5 0.2 5.6 4.9 10/16/2005 13:00:00 6.9 0.8 8.4 5.3 6.8 0.7 8.4 4.9 152 7 160 305 5 0.1 5.6 4.9 10/16/2005 13:10:00 6.4 1.1 9.1 3.4 6.5 0.9 9.5 4.2 157 6 154 305 5.3 0.1 5.9 4.9 10/16/2005 13:20:00 6.4 1 8.8 3.8 6.9 0.9 9.1 4.9 160 6 156 305 5.4 0.1 5.9 5.2 10/16/2005 13:30:00 6.1 0.8 8.4 3.8 6 0.7 8 4.2 152 7 147 305 5.5 0.1 5.9 5.4 10/16/2005 13:40:00 5.9 0.6 7.6 4.2 6.1 0.6 7.2 4.2 144 8 145 305 5.4 0.1 5.9 5.2 10/16/2005 13:50:00 6.2 0.7 8 3.8 6.2 0.7 8 4.2 147 8 161 305 5.5 0.1 5.9 5.2 10/16/2005 14:00:00 6.5 0.7 8 4.2 6.6 0.7 8.4 4.9 143 7 151 305 5.5 0.1 5.9 5.2 10/16/2005 14:10:00 6.5 0.7 8.8 4.6 6.5 0.7 8.8 4.6 139 6 136 305 5.4 0 5.9 5.2 10/16/2005 14:20:00 5.8 1 8 3 5.8 0.9 8 3 146 10 136 305 5.4 0.1 5.9 5.2 10/16/2005 14:30:00 6.2 1 9.1 3.4 6.4 0.9 8.4 4.2 152 10 161 305 5.3 0.1 5.9 4.9 10/16/2005 14:40:00 6.3 1 9.1 3.8 6.3 0.8 8.4 4.6 152 7 150 305 5.1 0.2 5.6 4.9 10/16/2005 14:50:00 5.7 0.8 8 4.2 5.8 0.7 7.6 4.2 149 11 148 305 5.2 0.1 5.6 4.9 10/16/2005 15:00:00 6.7 0.8 8.8 4.2 6.7 0.8 8.8 4.6 144 10 151 305 5.3 0.1 5.6 4.9 10/16/2005 15:10:00 6.3 1 9.1 4.2 6.4 1 8.8 3.8 146 10 132 305 5.2 0.1 5.6 4.9 10/16/2005 15:20:00 7 1 9.5 4.6 7.1 1.1 9.5 3.8 143 9 130 305 5.1 0.2 5.6 4.9 10/16/2005 15:30:00 7.6 1 9.9 4.9 7.6 0.9 10.3 5.3 142 8 149 305 5 0.2 5.6 4.9 10/16/2005 15:40:00 6.9 1 10.3 4.9 6.8 0.9 9.5 4.9 148 9 155 305 5 0.1 5.4 4.9 10/16/2005 15:50:00 7.8 1 10.3 5.7 7.8 1 9.9 5.3 143 9 139 305 4.9 0.1 5.4 4.9 10/16/2005 16:00:00 6.8 1 9.9 4.2 7 1.1 10.7 4.6 141 10 145 305 5 0.1 5.6 4.9 10/16/2005 16:10:00 5.8 1 8 3.4 5.8 1 8 3.8 141 10 137 305 5 0.1 5.4 4.9 10/16/2005 16:20:00 6.5 0.9 8.8 4.2 6.4 0.9 8.4 4.6 137 9 130 305 4.9 0 5.4 4.7 10/16/2005 16:30:00 6.1 1.2 8.8 3 6 1.1 9.1 3 138 9 129 305 4.8 0 5.4 4.7 10/16/2005 16:40:00 7.4 1.1 9.5 4.6 7.4 1 9.9 4.6 140 9 127 305 4.7 0 4.9 4.4 10/16/2005 16:50:00 7.6 1.1 10.3 3.8 7.7 1 9.5 4.2 142 11 154 305 4.5 0.1 4.9 4.4 10/16/2005 17:00:00 7.6 1.1 10.3 4.6 7.6 1 10.3 4.9 134 7 145 305 4.5 0.1 4.9 4.4 10/16/2005 17:10:00 5.4 1.1 8 1.9 5.4 1.1 8 2.6 130 13 120 305 4.5 0.1 4.9 4.4 10/16/2005 17:20:00 5.3 1.2 8.8 2.6 5.2 1.2 8.8 2.6 126 17 133 305 4.5 0.1 4.9 4.4 10/16/2005 17:30:00 5.7 1.2 9.1 2.3 5.7 1.2 9.9 2.3 125 19 130 305 4.4 0.1 4.9 4.2 10/16/2005 17:40:00 5.2 1.3 9.1 1.9 5.2 1.3 8.8 1.9 121 22 144 305 4.2 0.1 4.7 4.2 10/16/2005 17:50:00 4.3 1.3 8.8 1.5 4.2 1.3 8.4 1.5 105 24 70 305 4 0.2 4.4 3.7 10/16/2005 18:00:00 5.6 1.7 9.9 3 5.3 1.8 9.5 1.9 78 23 109 305 3.9 0.2 4.4 3.7 10/16/2005 18:10:00 5.8 1.6 10.3 1.9 5.8 1.5 9.9 3 75 21 69 305 3.9 0.2 4.4 3.7 10/16/2005 18:20:00 4.9 1.5 9.1 1.1 4.9 1.6 9.9 1.1 87 30 113 305 3.9 0.2 4.4 3.7 10/16/2005 18:30:00 5.4 1.7 11.8 1.5 5.5 1.6 11.1 1.5 75 28 56 305 3.9 0.2 4.4 3.7 10/16/2005 18:40:00 5.9 2.2 11.1 0.7 6.1 2.3 10.7 1.5 83 29 77 305 3.9 0.2 4.4 3.7 10/16/2005 18:50:00 8.1 1.9 12.6 4.6 7.8 1.8 11.5 3.4 77 14 90 305 3.7 0.1 4.4 3.4 10/16/2005 19:00:00 8.6 1.5 13.3 3.8 8.6 1.6 13 4.2 78 13 74 305 3.6 0.1 4.2 3.4 10/16/2005 19:10:00 8.5 1.1 11.8 4.9 8.4 1.1 12.2 5.3 81 8 70 305 3.5 0.2 3.9 3.2 10/16/2005 19:20:00 8.9 1.1 11.5 6.1 8.6 1.1 11.8 6.1 81 6 71 305 3.4 0.2 3.9 3.2 10/16/2005 19:30:00 10 0.9 12.2 6.8 9.8 1 11.8 6.8 79 6 80 305 3.3 0.1 3.7 2.9 10/16/2005 19:40:00 10 0.8 12.2 8 9.7 0.9 12.2 7.2 76 5 69 305 3.1 0.1 3.7 2.9 10/16/2005 19:50:00 10.9 1 13.7 8 10.7 1.1 13.7 8 74 5 78 305 3 0.1 3.7 2.7 10/16/2005 20:00:00 11.6 0.9 14.1 9.1 11.4 1.1 13.3 8 75 5 81 305 2.9 0.1 3.4 2.7 10/16/2005 20:10:00 12.4 0.8 14.1 10.3 12.5 0.8 14.9 9.5 73 5 71 305 2.8 0.1 3.2 2.7 10/16/2005 20:20:00 12.4 0.9 14.5 9.5 12.2 1 14.5 9.1 76 5 78 305 2.8 0.1 3.2 2.7 10/16/2005 20:30:00 12.8 0.7 14.9 11.1 12.8 0.8 14.9 10.3 72 5 67 305 2.9 0 3.4 2.9 10/16/2005 20:40:00 13.4 0.7 15.3 11.5 13.4 0.9 15.3 10.7 69 4 69 305 2.9 0 3.4 2.9 10/16/2005 20:50:00 14 0.8 16.1 11.8 13.9 1 16.1 11.5 71 3 70 305 2.9 0 3.4 2.9 10/16/2005 21:00:00 13.9 0.9 16.1 11.5 13.7 1 16.1 10.7 69 4 65 305 3 0 3.4 2.9 10/16/2005 21:10:00 13 1.2 16.4 10.3 12.9 1.3 16.8 10.3 67 6 63 305 3.1 0 3.7 2.9 10/16/2005 21:20:00 13.8 1 16.4 11.1 13.7 1.1 16.4 10.3 62 4 61 305 3.1 0 3.4 2.9 10/16/2005 21:30:00 14.7 1.1 16.8 10.7 14.6 1.2 17.2 9.9 70 5 67 305 3.3 0 3.7 3.2 10/16/2005 21:40:00 14.6 1 16.8 11.5 14.5 1.1 16.8 11.5 65 6 74 305 3.3 0 3.7 3.2 10/16/2005 21:50:00 15.3 1 17.2 11.5 15.2 1.1 17.6 11.8 63 4 61 305 3.3 0 3.7 2.9 10/16/2005 22:00:00 15.2 1.2 17.9 12.2 15.2 1.3 18.3 11.5 64 4 69 305 3.1 0 3.7 2.9 10/16/2005 22:10:00 15.7 1.1 18.7 12.2 15.7 1.2 18.7 11.8 59 5 61 305 3 0 3.4 2.9 10/16/2005 22:20:00 15.7 1 18.3 13.3 15.7 1.1 17.9 12.6 55 4 62 305 2.9 0 3.4 2.7 10/16/2005 22:30:00 15.9 1.2 18.7 12.6 15.8 1.3 18.7 12.6 53 4 56 305 2.9 0 3.4 2.7 10/16/2005 22:40:00 15.1 1.3 18.7 11.1 14.9 1.3 17.6 11.1 55 5 57 305 2.9 0 3.4 2.7 10/16/2005 22:50:00 16.5 1.2 19.1 12.6 16.4 1.4 19.1 12.2 53 4 51 305 2.9 0.1 3.4 2.7 10/16/2005 23:00:00 15.8 1.5 18.3 11.8 15.5 1.6 19.1 11.1 53 4 48 305 2.9 0 3.4 2.9 10/16/2005 23:10:00 16.7 1.2 19.1 13.3 16.6 1.3 19.5 13 51 4 53 305 2.9 0.1 3.4 2.7 10/16/2005 23:20:00 16.6 1.3 19.1 12.2 16.5 1.5 19.1 11.8 50 4 52 305 2.9 0.1 3.4 2.7 10/16/2005 23:30:00 17 1.1 19.5 14.1 16.8 1.2 19.9 13.3 47 4 40 305 2.8 0.1 3.2 2.7 10/16/2005 23:40:00 16.9 1.2 19.5 13.3 16.8 1.3 19.9 13 47 5 51 305 2.8 0.1 3.2 2.7 10/16/2005 23:50:00 16.6 1.5 20.2 12.6 16.5 1.5 19.9 11.8 44 5 38 305 2.8 0.1 3.2 2.7 10/17/2005 00:00:00 16.8 1.5 20.2 11.8 16.8 1.5 19.9 12.6 46 4 52 305 2.7 0 3.2 2.7 10/17/2005 00:10:00 17.4 1.6 20.2 13.3 17.2 1.7 20.6 13.3 43 5 44 305 2.8 0.1 3.2 2.5 10/17/2005 00:20:00 17.1 1.5 20.6 12.2 16.9 1.6 20.2 12.2 38 5 38 305 2.6 0 3.2 2.5 10/17/2005 00:30:00 17 1.2 19.9 13.3 16.8 1.2 20.2 13.3 35 4 38 305 2.6 0 3.2 2.5 10/17/2005 00:40:00 17.6 1.3 20.6 13.3 17.4 1.3 20.2 13.3 35 3 36 305 2.5 0.1 2.9 2.2 10/17/2005 00:50:00 17.3 1.2 19.9 13.3 17.1 1.2 19.5 12.6 36 5 35 305 2.4 0.1 2.9 2.2 10/17/2005 01:00:00 16.6 1.2 20.2 13 16.4 1.3 20.2 12.6 33 5 35 305 2.3 0.1 2.7 2.2 10/17/2005 01:10:00 16.8 1.3 20.2 13 16.4 1.5 20.2 12.2 31 3 34 305 2.3 0.1 2.9 2.2 10/17/2005 01:20:00 17.6 1.2 20.6 13.3 17.4 1.3 21 13 29 4 33 305 2.2 0.1 2.7 2 10/17/2005 01:30:00 17.4 1.4 20.2 13.7 17.1 1.5 20.6 13.3 30 4 33 305 2.2 0.1 2.7 2 10/17/2005 01:40:00 17.2 1.2 19.9 14.1 17 1.4 19.9 13.3 28 3 23 305 2 0 2.5 2 10/17/2005 01:50:00 17.1 1.2 19.9 13.7 16.8 1.3 20.2 13.3 26 4 23 305 2 0.1 2.5 1.7 10/17/2005 02:00:00 16.2 1.2 19.5 13 16.1 1.3 18.7 12.2 26 4 30 305 2.1 0 2.5 2 10/17/2005 02:10:00 17.9 1.5 20.6 13 17.7 1.5 21 13.3 24 4 26 305 1.8 0.1 2.5 1.5 10/17/2005 02:20:00 17.8 1.3 21 13.7 17.7 1.3 21 13.7 26 4 22 305 1.9 0.1 2.5 1.5 10/17/2005 02:30:00 18.5 1.5 22.1 14.9 18.2 1.6 22.1 14.9 26 4 27 305 1.9 0 2.5 2 10/17/2005 02:40:00 17.4 1.5 20.6 12.6 17.1 1.5 20.6 13 25 4 30 305 1.9 0.1 2.5 1.5 10/17/2005 02:50:00 17.7 1.5 20.6 13.7 17.7 1.5 21 13 25 4 22 305 1.9 0.1 2.5 1.5 10/17/2005 03:00:00 17.6 1.5 20.6 13 17.3 1.6 21 13 24 4 27 305 2 0.1 2.5 1.7 10/17/2005 03:10:00 18.4 1.5 22.1 14.9 18.2 1.5 22.6 14.5 23 4 23 305 2 0.1 2.5 2 10/17/2005 03:20:00 18.3 1.5 21.4 14.1 18.1 1.5 21.4 14.1 23 4 25 305 2.2 0.1 2.7 2 10/17/2005 03:30:00 18.9 1.5 22.1 14.5 18.7 1.7 22.1 14.5 24 4 29 305 2.2 0.1 2.7 2 10/17/2005 03:40:00 18.8 1.8 22.9 14.5 18.5 1.8 22.1 14.5 24 4 24 305 2.1 0.1 2.7 2 10/17/2005 03:50:00 18.8 1.6 22.1 14.9 18.6 1.7 22.1 13.7 24 4 27 305 1.9 0.2 2.5 1.5 10/17/2005 04:00:00 18 1.3 20.6 13.7 17.8 1.3 21 14.1 21 4 13 305 1.7 0.2 2.2 1.5 10/17/2005 04:10:00 17.9 1.7 22.6 13.3 17.7 1.8 23.3 13 21 5 19 305 1.9 0.2 2.5 1.5 10/17/2005 04:20:00 19.5 1.5 22.9 15.6 19.3 1.5 22.6 15.3 20 4 19 305 1.9 0.2 2.5 1.5 10/17/2005 04:30:00 19.1 1.4 22.6 15.3 19 1.5 22.9 14.9 19 4 26 305 1.9 0.2 2.5 1.5 10/17/2005 04:40:00 18.3 1.5 21.8 14.9 18.1 1.6 21.8 14.1 15 4 19 305 1.8 0.2 2.5 1.5 10/17/2005 04:50:00 17.7 1.7 21 13 17.6 1.7 21.4 13 14 4 18 305 1.9 0.2 2.5 1.5 10/17/2005 05:00:00 17.8 1.4 21 14.5 17.6 1.7 21 13 13 4 15 305 1.8 0.2 2.5 1.5 10/17/2005 05:10:00 18.7 1.3 22.1 15.3 18.6 1.5 22.9 14.5 11 4 8 305 1.8 0.1 2.2 1.5 10/17/2005 05:20:00 18.1 1.7 22.1 13.7 18.1 1.7 21.4 13.7 10 4 9 305 1.8 0.2 2.2 1.5 10/17/2005 05:30:00 18.1 1.5 21 12.2 18 1.7 21.8 13 10 4 8 305 1.8 0.2 2.2 1.5 10/17/2005 05:40:00 18.5 1.5 21.4 13.7 18.4 1.6 21.8 13.7 7 4 3 305 1.8 0.2 2.2 1.5 10/17/2005 05:50:00 17.3 1.3 22.1 13.7 17.1 1.5 21.4 13 7 5 12 305 1.9 0.2 2.5 1.5 10/17/2005 06:00:00 18.3 1.5 22.6 14.9 18.2 1.7 22.1 14.1 5 4 3 305 1.9 0.1 2.5 1.5 10/17/2005 06:10:00 18.5 1.4 21.8 14.5 18.6 1.5 22.9 14.1 4 4 2 305 1.9 0.2 2.5 1.5 10/17/2005 06:20:00 18.9 1.3 22.6 15.3 18.9 1.4 22.6 14.5 2 4 0 305 1.9 0.2 2.5 1.5 10/17/2005 06:30:00 17.9 1.5 22.6 14.1 17.9 1.7 22.1 13.3 0 5 2 305 1.9 0.1 2.5 1.5 10/17/2005 06:40:00 18.3 1.5 21.8 14.9 18.4 1.6 22.1 13.7 1 4 359 305 1.9 0.1 2.5 1.7 10/17/2005 06:50:00 19 1.5 22.6 14.5 19 1.7 22.6 13.7 0 4 358 305 1.9 0.1 2.5 1.7 10/17/2005 07:00:00 18.5 1.6 22.9 14.1 18.6 1.8 22.9 13.7 0 4 2 305 2 0.1 2.5 1.7 10/17/2005 07:10:00 17.7 1.7 21.8 13 17.7 1.7 21.4 13.3 359 4 3 305 2.1 0.1 2.5 2 10/17/2005 07:20:00 18.4 1.7 21.8 14.1 18.5 1.8 22.1 13.7 357 4 6 305 2.1 0.1 2.7 2 10/17/2005 07:30:00 18.1 1.5 21.8 14.5 18.2 1.6 22.6 14.5 353 4 355 305 2 0.2 2.5 1.7 10/17/2005 07:40:00 17.7 1.6 21 13.3 17.9 1.7 21.8 13.3 354 4 359 305 2 0.1 2.5 1.7 10/17/2005 07:50:00 17.5 1.3 21 13 17.6 1.5 21.4 13.3 350 4 352 305 1.8 0.2 2.5 1.5 10/17/2005 08:00:00 18.5 1.8 22.1 13 18.6 1.9 22.9 14.1 350 4 350 305 1.7 0.1 2.2 1.5 10/17/2005 08:10:00 19.5 1.5 22.9 15.6 19.8 1.4 23.7 15.3 350 3 349 305 1.6 0.1 2.2 1.5 10/17/2005 08:20:00 19 1.5 22.1 14.9 19.2 1.6 22.6 13.3 350 4 348 305 1.6 0.1 2.2 1.5 10/17/2005 08:30:00 19.3 1.6 23.3 14.9 19.5 1.7 23.3 14.5 349 4 351 305 1.7 0.2 2.2 1.5 10/17/2005 08:40:00 19.6 1.6 23.3 14.5 19.8 1.7 23.7 14.5 348 4 349 305 1.7 0.2 2.2 1.5 10/17/2005 08:50:00 18.7 1.9 22.9 14.5 18.9 1.9 23.7 13 346 5 348 305 1.7 0.2 2.2 1.5 10/17/2005 09:00:00 18.5 2.1 23.3 13.3 18.5 2.2 23.7 13 346 5 345 305 1.8 0.2 2.2 1.5 10/17/2005 09:10:00 18.8 2.1 22.9 13.7 19 2.2 23.7 14.1 343 5 343 305 1.7 0.2 2.2 1.5 10/17/2005 09:20:00 20 1.8 23.7 14.9 20.1 1.9 23.7 14.5 343 4 339 305 1.6 0.1 2.2 1.5 10/17/2005 09:30:00 20.5 1.9 25.2 15.3 20.7 2 25.2 15.3 343 4 346 305 1.6 0.1 2.2 1.5 10/17/2005 09:40:00 19.9 1.7 24 15.3 20.1 1.8 24 15.3 343 4 341 305 1.7 0.1 2.2 1.5 10/17/2005 09:50:00 19.6 1.8 23.7 13.3 19.7 1.9 24 14.1 343 5 342 305 1.7 0.2 2.2 1.5 10/17/2005 10:00:00 20.4 1.6 24 14.9 20.5 1.7 24 15.3 341 5 343 305 1.7 0.1 2.2 1.5 10/17/2005 10:10:00 19.5 1.9 23.7 14.1 19.4 2 24 14.5 341 5 344 305 1.7 0.1 2.2 1.5 10/17/2005 10:20:00 20.9 1.5 24.8 16.8 21.1 1.7 24.8 16.8 342 4 340 305 1.6 0.1 2.2 1.5 10/17/2005 10:30:00 19.1 1.9 24 14.5 19.2 2 25.2 13.7 343 5 343 305 1.7 0.1 2.2 1.5 10/17/2005 10:40:00 19.7 1.8 24 14.9 19.7 2 24 14.5 340 4 338 305 1.6 0 2.2 1.5 10/17/2005 10:50:00 19.8 2.2 24.4 14.1 19.9 2.2 24.8 14.1 341 5 340 305 1.6 0.1 2.2 1.5 10/17/2005 11:00:00 19.6 1.9 23.7 13.3 19.6 2.1 24.4 13.7 341 5 344 305 1.6 0.1 2.2 1.5 10/17/2005 11:10:00 19.7 1.9 23.7 14.5 19.8 2.1 24.4 14.9 341 5 339 305 1.7 0.2 2.2 1.5 10/17/2005 11:20:00 19.5 1.7 23.3 15.6 19.4 1.7 24 15.3 341 5 337 305 1.7 0.1 2.2 1.5 10/17/2005 11:30:00 18.3 1.8 22.9 13.7 18.4 1.8 23.3 14.1 341 4 350 305 1.7 0.1 2.2 1.5 10/17/2005 11:40:00 18.1 1.9 22.9 13.3 18.2 2.1 23.3 13.3 340 5 341 305 1.6 0.1 2.2 1.3 10/17/2005 11:50:00 17.6 1.5 20.6 13.3 17.8 1.6 21 13 339 5 340 305 1.4 0.2 2 1.3 10/17/2005 12:00:00 17.9 1.9 21.8 13 18 1.8 21.8 13.3 338 5 334 305 1.3 0.1 2 1 10/17/2005 12:10:00 19 1.6 22.1 14.9 19.1 1.7 22.9 14.5 338 4 331 305 1.3 0.2 1.7 1 10/17/2005 12:20:00 18.6 1.7 22.1 14.1 18.8 1.9 22.9 13.3 337 4 333 305 1.3 0.1 2 1 10/17/2005 12:30:00 18.8 1.5 22.1 14.5 18.8 1.7 22.6 14.1 337 5 344 305 1.4 0.1 2 1.3 10/17/2005 12:40:00 18.5 2.1 22.6 13.3 18.6 2.1 22.6 13 337 4 334 305 1.5 0.1 2.2 1.3 10/17/2005 12:50:00 19.4 1.9 24 12.2 19.5 1.9 23.7 12.2 338 4 340 305 1.6 0.1 2.2 1.3 10/17/2005 13:00:00 19.3 1.8 23.7 14.1 19.3 1.9 22.9 13.3 335 4 332 305 1.7 0.1 2.2 1.5 10/17/2005 13:10:00 18.2 2 22.6 13.3 18.2 2 22.6 13 337 4 337 305 1.7 0.2 2.2 1.5 10/17/2005 13:20:00 18.7 1.6 22.6 14.9 18.6 1.7 22.9 14.5 336 5 332 305 1.7 0.2 2.2 1.5 10/17/2005 13:30:00 17.7 1.8 21.4 13 17.7 1.8 21.4 12.6 334 5 341 305 1.7 0.1 2.2 1.5 10/17/2005 13:40:00 17.3 1.5 21 12.6 17.6 1.7 21 11.8 335 4 339 305 1.7 0.1 2.2 1.5 10/17/2005 13:50:00 17.1 1.7 21.4 12.6 17.1 1.7 21.8 12.6 333 5 332 305 1.7 0.2 2.2 1.5 10/17/2005 14:00:00 17.7 1.7 21 13 17.6 1.7 21.4 13 333 4 333 305 1.7 0.2 2.2 1.5 10/17/2005 14:10:00 16.4 1.7 20.2 12.2 16.4 1.7 20.2 11.5 330 5 329 305 1.9 0.1 2.5 1.5 10/17/2005 14:20:00 15.9 1.6 19.9 11.5 15.8 1.7 19.5 11.1 329 6 323 305 1.9 0.1 2.5 1.7 10/17/2005 14:30:00 17 1.5 20.2 13 17 1.7 20.6 12.2 330 5 328 305 1.9 0.1 2.5 1.7 10/17/2005 14:40:00 15.7 1.3 19.1 12.2 15.8 1.5 19.1 11.8 328 5 333 305 1.8 0.2 2.5 1.5 10/17/2005 14:50:00 15 1.5 19.1 10.7 14.9 1.7 18.7 10.7 328 5 336 305 1.8 0.2 2.2 1.5 10/17/2005 15:00:00 15.2 1.5 18.3 10.7 15.1 1.5 19.1 10.7 327 4 329 305 1.7 0.1 2.2 1.5 10/17/2005 15:10:00 15.3 1.3 18.3 11.8 15.2 1.4 19.1 11.5 327 4 327 305 1.9 0.2 2.2 1.5 10/17/2005 15:20:00 14.7 1.7 17.6 10.7 14.6 1.6 18.3 10.3 326 6 324 305 2 0.2 2.7 1.5 10/17/2005 15:30:00 15.9 1.5 19.1 11.1 15.8 1.6 19.5 11.1 327 6 325 305 2.2 0.1 2.5 2 10/17/2005 15:40:00 16.1 1.7 19.5 11.5 16.1 1.7 19.9 11.8 329 5 330 305 2 0.1 2.7 2 10/17/2005 15:50:00 15.5 1.5 18.7 11.5 15.5 1.6 18.7 10.3 329 4 330 305 2 0.1 2.5 2 10/17/2005 16:00:00 15.2 1.7 18.3 9.9 15.2 1.7 18.7 10.3 327 5 326 305 2.1 0.1 2.7 2 10/17/2005 16:10:00 15.1 1.7 18.7 10.3 15.1 1.9 19.1 9.9 326 5 337 305 2.2 0.1 2.7 2 10/17/2005 16:20:00 14.3 1.3 17.2 10.3 14.2 1.5 17.2 9.5 325 6 325 305 2.3 0.2 2.7 2.2 10/17/2005 16:30:00 14.5 2 19.1 9.9 14.5 2.1 19.1 9.9 325 6 316 305 2.5 0.1 2.9 2.2 10/17/2005 16:40:00 15.5 1.4 18.7 11.5 15.4 1.5 18.7 11.1 325 5 323 305 2.7 0 3.2 2.5 10/17/2005 16:50:00 15.7 1.7 19.5 10.3 15.4 1.8 19.9 9.9 326 6 323 305 2.9 0.1 3.2 2.7 10/17/2005 17:00:00 14.5 1.5 18.3 11.1 14.5 1.5 18.7 10.3 327 6 330 305 2.8 0.1 3.2 2.7 10/17/2005 17:10:00 14.5 1.3 17.2 10.7 14.5 1.3 17.2 10.3 327 5 325 305 2.8 0.1 3.2 2.7 10/17/2005 17:20:00 13.5 1.3 16.8 9.5 13.4 1.3 16.4 10.3 319 12 322 305 2.8 0.1 3.2 2.5 10/17/2005 17:30:00 13.6 1.3 16.4 9.5 13.3 1.4 16.4 9.9 310 15 310 305 2.4 0 2.7 2.2 10/17/2005 17:40:00 14.7 1.3 16.8 10.7 14.3 1.4 17.2 9.5 308 17 312 305 2.3 0.1 2.7 2.2 10/17/2005 17:50:00 14.5 1.5 17.6 9.9 14.1 1.5 17.6 9.5 309 16 305 305 2.2 0.1 2.7 2.2 10/17/2005 18:00:00 15.3 1.5 17.9 10.3 15 1.7 17.9 10.3 310 17 305 305 2.2 0 2.7 2 10/17/2005 18:10:00 15.1 1.2 17.9 11.1 14.7 1.3 17.2 11.5 309 18 297 305 2 0 2.5 2 10/17/2005 18:20:00 15.2 1.3 17.9 11.8 14.7 1.5 17.9 11.1 309 20 306 305 1.9 0 2.2 1.7 10/17/2005 18:30:00 15 1.4 17.9 10.7 14.6 1.5 17.9 10.3 308 9 306 305 1.8 0.1 2.2 1.5 10/17/2005 18:40:00 14.5 1.3 17.6 10.3 14.2 1.5 17.2 10.3 309 21 302 305 1.9 0.1 2.2 1.7 10/17/2005 18:50:00 14.9 1.4 17.6 10.7 14.6 1.4 17.2 10.7 307 22 305 305 1.9 0.1 2.5 1.7 10/17/2005 19:00:00 13.6 1.3 16.8 9.9 13.2 1.4 16.4 9.5 308 15 305 305 2.2 0.1 2.7 2 10/17/2005 19:10:00 13.9 1.2 16.4 10.3 13.6 1.3 16.4 9.1 310 15 317 305 2.2 0 2.7 2.2 10/17/2005 19:20:00 13.4 1.2 16.4 10.3 13.2 1.3 16.4 9.9 314 12 307 305 2.2 0.1 2.7 2.2 10/17/2005 19:30:00 11.7 1.1 14.5 8.8 11.5 1.2 14.1 8.4 312 7 310 305 2.5 0.1 2.9 2.2 10/17/2005 19:40:00 11.7 0.9 13.3 9.1 11.6 1.1 13.7 8.4 313 17 311 305 2.4 0 2.7 2.2 10/17/2005 19:50:00 12.4 0.9 14.1 9.5 12.3 1 14.1 9.1 309 17 307 305 2.4 0 2.9 2.2 10/17/2005 20:00:00 11.9 1 14.1 9.5 11.6 1 14.5 8.8 307 26 294 305 2.3 0.1 2.7 2.2 10/17/2005 20:10:00 12.7 1.1 14.9 8.8 12.5 1.1 14.5 8.4 306 21 313 305 2.3 0.1 2.7 2.2 10/17/2005 20:20:00 11.9 1 14.1 8.8 11.7 1 14.1 8.8 307 15 304 305 2.3 0.1 2.7 2.2 10/17/2005 20:30:00 12.7 0.9 15.3 10.7 12.4 1 14.9 9.9 308 19 327 305 2.3 0.1 2.7 2.2 10/17/2005 20:40:00 11.7 1 14.1 9.1 11.5 1 13.7 8.8 306 13 305 305 2.4 0.1 2.9 2.2 10/17/2005 20:50:00 12 1 13.7 9.1 11.8 1.1 14.1 7.6 310 22 306 305 2.3 0.1 2.7 2.2 10/17/2005 21:00:00 11.3 1.2 13.7 8 11.1 1.2 13.7 8 306 21 316 305 2.3 0.1 2.7 2.2 10/17/2005 21:10:00 11.3 0.9 13 8.4 10.9 1 13 8 305 20 305 305 2.3 0.1 2.7 2.2 10/17/2005 21:20:00 10.9 1 12.6 7.6 10.7 1 12.6 7.6 301 18 281 305 2.2 0 2.7 2 10/17/2005 21:30:00 11.6 1 13.3 8.4 11.4 1.1 13.7 8.4 300 17 305 305 2.2 0 2.5 2 10/17/2005 21:40:00 11.5 1 13.3 8.4 11.1 1.1 13.3 8 295 7 288 305 2.2 0 2.5 2 10/17/2005 21:50:00 12 0.8 13.3 9.1 11.6 1 13.3 8.8 297 17 297 305 2.2 0 2.7 2 10/17/2005 22:00:00 11.8 0.8 13.7 9.1 11.3 1 13.3 8.8 294 11 303 305 2.1 0 2.5 2 10/17/2005 22:10:00 11.8 1.2 14.5 8 11.3 1.4 14.5 7.2 291 6 289 305 2 0 2.5 2 10/17/2005 22:20:00 11.9 1.2 14.5 8.8 11.3 1.3 13.7 8.4 292 7 294 305 2.1 0 2.5 2 10/17/2005 22:30:00 12.2 1.4 14.9 8 11.5 1.5 14.5 7.6 290 9 285 305 2.1 0 2.5 2 10/17/2005 22:40:00 12.6 1.1 14.9 9.1 12.1 1.3 14.5 7.6 292 13 287 305 2 0 2.5 2 10/17/2005 22:50:00 11.7 1 13.3 8.8 11.2 1.3 13.3 7.6 291 12 287 305 2.1 0 2.5 2 10/17/2005 23:00:00 12.3 1 14.9 9.5 11.9 1.1 14.5 8.4 293 7 290 305 2.1 0 2.5 2 10/17/2005 23:10:00 11.7 1.4 14.1 8 11.2 1.5 14.1 7.6 293 12 294 305 2 0.1 2.5 2 10/17/2005 23:20:00 11.9 1.3 14.9 8.8 11.3 1.3 14.1 8 292 12 290 305 2 0 2.5 2 10/17/2005 23:30:00 11.5 1 13.7 8 11 1.1 13.3 7.6 294 15 290 305 1.9 0 2.5 1.7 10/17/2005 23:40:00 12.2 0.9 14.5 9.5 11.9 1.1 14.5 8.4 296 9 295 305 1.9 0.1 2.2 1.7 10/17/2005 23:50:00 11.6 1.1 14.1 8.4 11.3 1.1 13.7 8 295 7 291 305 1.9 0.1 2.5 1.7 10/18/2005 00:00:00 11.3 1 13.3 8.4 10.9 1.1 13 7.6 292 6 288 305 1.9 0 2.2 1.7 10/18/2005 00:10:00 9.6 0.9 11.8 6.8 9.2 1 11.1 6.5 295 18 296 305 1.8 0 2.2 1.7 10/18/2005 00:20:00 9.7 0.8 11.5 7.2 9.4 1 11.1 7.2 295 13 300 305 1.7 0.1 2.2 1.5 10/18/2005 00:30:00 8.8 0.9 11.1 6.1 8.6 1 10.7 5.7 299 18 302 305 1.7 0.1 2.2 1.5 10/18/2005 00:40:00 7.9 0.8 9.9 6.1 7.8 0.8 9.5 5.7 295 13 286 305 1.7 0.1 2.2 1.5 10/18/2005 00:50:00 8.6 1.2 11.1 5.3 8.2 1.4 11.1 5.3 296 18 294 305 1.7 0.1 2.2 1.5 10/18/2005 01:00:00 8.7 0.8 10.7 6.1 8.4 0.8 10.3 6.1 292 9 287 305 1.7 0.1 2.2 1.5 10/18/2005 01:10:00 8.5 0.6 9.9 6.8 8.2 0.7 9.9 6.5 290 6 290 305 1.6 0.1 2.2 1.5 10/18/2005 01:20:00 8.5 0.8 10.3 6.1 8.1 0.9 9.9 5.3 288 6 287 305 1.6 0.1 2.2 1.5 10/18/2005 01:30:00 8.8 0.7 10.7 6.5 8.3 0.9 10.3 5.7 288 7 292 305 1.7 0.1 2.2 1.5 10/18/2005 01:40:00 8.8 0.8 10.3 6.5 8.3 0.8 10.3 6.5 289 6 287 305 1.6 0 2.2 1.5 10/18/2005 01:50:00 7.8 1 10.3 4.9 7.3 1 9.5 4.2 283 7 282 305 1.6 0 2 1.5 10/18/2005 02:00:00 7.7 0.8 9.1 4.9 6.9 0.8 8.8 4.6 281 8 275 305 1.4 0 2 1.3 10/18/2005 02:10:00 7.6 0.8 9.5 4.9 7.3 0.9 9.1 4.9 288 7 294 305 1.3 0.1 1.7 1.3 10/18/2005 02:20:00 7.5 0.8 9.5 5.3 7 0.9 8.8 4.9 287 9 284 305 1.3 0 1.7 1.3 10/18/2005 02:30:00 7.2 0.8 8.8 4.9 7 0.8 8.4 4.9 292 9 301 305 1.2 0.1 1.7 1 10/18/2005 02:40:00 7.4 0.6 8.8 5.3 6.9 0.8 8.4 3.8 280 11 282 305 1.3 0.1 1.7 1 10/18/2005 02:50:00 7.1 0.6 8.8 5.3 6.2 0.7 8 3.8 275 6 274 305 1.3 0.1 1.7 1 10/18/2005 03:00:00 6.3 0.7 8 4.2 5.9 0.7 7.6 3.8 283 7 275 305 1.2 0.1 1.5 1 10/18/2005 03:10:00 5.8 0.7 7.2 3.4 5.5 0.7 6.8 3.4 288 8 282 305 1.2 0.1 1.5 1 10/18/2005 03:20:00 5.9 0.7 7.2 4.2 5.7 0.8 7.6 3.8 286 7 295 305 1.2 0.1 1.7 1 10/18/2005 03:30:00 5.6 0.8 7.6 3.4 4.9 0.8 6.8 2.6 273 9 280 305 1.3 0.1 1.7 1 10/18/2005 03:40:00 5.6 0.6 6.8 3.8 4.9 0.7 6.5 3 276 9 269 305 1.2 0.1 1.5 1 10/18/2005 03:50:00 5.3 0.7 6.5 3.4 4.8 0.8 6.5 1.9 277 9 285 305 1.2 0.1 1.5 1 10/18/2005 04:00:00 5.4 0.7 7.2 3.8 4.6 0.7 6.1 2.6 271 8 264 305 1.1 0.1 1.5 1 10/18/2005 04:10:00 5.4 0.5 6.8 4.2 4.7 0.6 6.5 3 272 6 280 305 1.1 0.1 1.5 1 10/18/2005 04:20:00 5.3 0.6 6.8 3.4 4.6 0.6 6.1 2.6 274 8 268 305 1.2 0.1 1.5 1 10/18/2005 04:30:00 5.6 0.5 6.5 3.8 4.6 0.6 6.1 3 267 7 259 305 1.2 0.2 1.5 1 10/18/2005 04:40:00 4.9 0.9 6.8 2.6 4.1 0.8 6.1 2.3 270 8 261 305 1.2 0.1 1.7 1 10/18/2005 04:50:00 5.2 0.6 6.5 3.4 4.6 0.7 6.1 3 271 8 278 305 1.3 0.2 1.7 1 10/18/2005 05:00:00 5.4 0.8 6.8 3 4.8 0.9 6.5 2.6 276 8 280 305 1.2 0.2 1.7 1 10/18/2005 05:10:00 5.7 0.5 6.8 4.6 5.4 0.5 6.5 3.8 281 7 280 305 1.2 0.2 1.5 1 10/18/2005 05:20:00 5.1 0.5 6.8 3.8 4.5 0.6 5.7 2.6 277 7 277 305 1.2 0.1 1.5 1 10/18/2005 05:30:00 4.7 0.5 6.1 3 4.2 0.7 5.7 2.3 280 7 285 305 1 0.1 1.5 0.8 10/18/2005 05:40:00 5.3 0.6 6.8 3 4.4 0.6 6.1 2.3 270 6 272 305 1 0.1 1.5 0.8 10/18/2005 05:50:00 5.7 0.6 6.8 3.8 5 0.7 6.5 3.4 276 6 273 305 1 0.1 1.5 0.8 10/18/2005 06:00:00 5.5 0.7 6.8 3 4.7 0.7 6.1 3 273 6 273 305 1 0.1 1.5 0.8 10/18/2005 06:10:00 5 0.6 6.8 3.4 4.1 0.6 5.7 2.6 268 8 275 305 1 0.1 1.5 0.8 10/18/2005 06:20:00 5.7 0.7 7.6 3.8 4.9 0.7 6.8 3 276 6 275 305 1 0.1 1.5 0.8 10/18/2005 06:30:00 5.5 0.6 6.8 3.8 4.5 0.6 6.5 3 271 7 267 305 1 0.1 1.5 0.8 10/18/2005 06:40:00 4.5 0.6 6.1 3 3.8 0.6 5.7 2.6 273 6 266 305 0.9 0 1.5 0.8 10/18/2005 06:50:00 4.7 0.4 6.1 3.4 3.8 0.5 4.9 2.3 260 7 261 305 1 0 1.5 0.8 10/18/2005 07:00:00 4.8 0.6 6.1 3.4 4.1 0.8 6.1 2.3 257 7 251 305 1 0 1.5 0.8 10/18/2005 07:10:00 4.9 0.5 6.1 3.8 4.3 0.6 5.7 2.3 253 8 267 305 1 0 1.5 0.8 10/18/2005 07:20:00 5 0.5 6.1 3.8 4.4 0.6 5.7 2.3 253 6 255 305 1 0 1.5 1 10/18/2005 07:30:00 4.9 0.6 6.8 3.4 4.4 0.8 6.8 2.3 250 7 239 305 1.1 0.1 1.5 1 10/18/2005 07:40:00 5 0.6 6.5 3.4 4.6 0.7 6.5 3 243 8 238 305 1.2 0.1 1.5 1 10/18/2005 07:50:00 4.5 0.5 6.1 2.6 4 0.6 5.7 2.3 247 7 249 305 1.1 0.1 1.5 1 10/18/2005 08:00:00 4.1 0.8 5.3 1.9 3.5 0.9 5.3 1.1 247 13 236 305 1.1 0 1.5 1 10/18/2005 08:10:00 4 0.5 5.7 2.6 3.3 0.5 5.7 1.9 258 10 256 305 1.1 0 1.5 1 10/18/2005 08:20:00 4.2 0.6 5.7 2.6 3.3 0.6 4.6 1.9 260 5 258 305 1 0 1.5 1 10/18/2005 08:30:00 3.8 0.6 4.9 2.3 3.4 0.6 4.9 1.9 245 12 263 305 1 0 1.5 0.8 10/18/2005 08:40:00 3.3 0.6 4.6 1.9 3.2 0.5 4.6 2.3 229 5 222 305 0.9 0 1.3 0.8 10/18/2005 08:50:00 3.5 0.4 4.2 2.3 3.3 0.4 4.2 2.3 224 7 225 305 0.9 0 1.5 0.8 10/18/2005 09:00:00 3.4 0.4 4.2 2.6 3.1 0.4 4.2 1.9 231 5 236 305 0.8 0 1.3 0.6 10/18/2005 09:10:00 3.1 0.4 4.2 2.3 3 0.4 4.2 2.3 236 5 236 305 0.7 0 1.3 0.6 10/18/2005 09:20:00 2.8 0.5 3.8 1.5 2.8 0.4 3.8 1.9 231 4 234 305 0.7 0.1 1 0.6 10/18/2005 09:30:00 2.3 0.4 3.4 1.5 2.3 0.4 3.4 1.5 226 6 224 305 0.6 0.1 1 0.6 10/18/2005 09:40:00 2.1 0.4 3 1.1 2.2 0.3 3 1.5 231 7 229 305 0.7 0 1.3 0.6 10/18/2005 09:50:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 1.5 225 12 223 305 0.9 0 1 0.6 10/18/2005 10:00:00 2.2 0.6 3.4 1.1 2.2 0.5 3.8 1.1 214 9 227 305 0.8 0 1 0.6 10/18/2005 10:10:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.5 219 6 208 305 1 0 1.3 0.8 10/18/2005 10:20:00 2 0.7 3 0.4 2.3 0.6 3.4 1.1 202 9 206 305 1 0 1.5 0.8 10/18/2005 10:30:00 0.5 0.3 1.5 0.4 1.2 0.5 1.9 0.4 178 23 179 305 1.1 0 1.5 1 10/18/2005 10:40:00 0.4 0.2 1.5 0.4 0.9 0.4 1.9 0.4 163 21 196 305 1 0 1.5 1 10/18/2005 10:50:00 0.7 0.4 1.9 0.4 1.2 0.4 2.3 0.4 120 8 138 305 1 0 1.5 1 10/18/2005 11:00:00 0.8 0.5 1.9 0.4 1.4 0.5 2.3 0.4 110 8 123 305 1.1 0.1 1.5 1 10/18/2005 11:10:00 1.6 0.4 2.6 0.7 2.1 0.3 2.6 1.5 109 5 111 305 1.1 0.1 1.5 1 10/18/2005 11:20:00 2.4 0.4 3.4 1.5 2.8 0.4 3.4 1.9 125 5 117 305 1.2 0.1 1.5 1 10/18/2005 11:30:00 2.3 0.4 3 1.5 2.7 0.4 3.4 1.9 120 6 120 305 1.1 0.1 1.5 1 10/18/2005 11:40:00 1 0.5 1.9 0.4 1.6 0.5 2.6 0.7 121 9 111 305 1.1 0.1 1.5 1 10/18/2005 11:50:00 1 0.5 2.3 0.4 1.5 0.3 2.3 0.7 125 17 105 305 1 0 1.5 1 10/18/2005 12:00:00 2 0.7 4.2 0.4 2.4 0.5 4.2 1.5 118 20 108 305 1 0 1.5 0.8 10/18/2005 12:10:00 2.3 1.1 4.6 0.4 2.6 1 4.9 0.4 85 28 61 305 1.1 0 1.5 1 10/18/2005 12:20:00 2.9 0.6 4.6 1.5 3 0.5 4.6 1.9 70 11 67 305 1.1 0.1 1.5 1 10/18/2005 12:30:00 3.1 1.1 4.9 0.4 3.2 0.9 4.9 0.7 78 12 73 305 1.3 0.1 2 1 10/18/2005 12:40:00 4 0.6 5.7 2.6 4 0.6 5.3 2.6 82 10 71 305 1.5 0.1 2.2 1.3 10/18/2005 12:50:00 4.6 0.6 6.1 3.4 4.6 0.6 6.5 3 64 6 60 305 1.3 0.2 2 1 10/18/2005 13:00:00 4.6 0.8 6.1 2.6 4.5 0.8 6.1 2.6 65 9 70 305 1.3 0.2 2 1 10/18/2005 13:10:00 4.9 0.5 6.5 3.4 5.1 0.5 6.8 3.8 65 4 60 305 1.1 0.1 1.5 1 10/18/2005 13:20:00 5 0.8 6.8 3 4.9 0.8 6.8 2.6 72 7 77 305 1.2 0.2 1.5 1 10/18/2005 13:30:00 5.7 0.5 6.8 4.2 5.7 0.5 6.8 3.8 61 5 65 305 1.3 0.1 1.7 1 10/18/2005 13:40:00 6.3 0.6 8 4.6 6.2 0.6 8 4.6 66 4 60 305 1.4 0 2 1.3 10/18/2005 13:50:00 6.8 0.4 8 5.7 6.7 0.4 8 5.3 65 4 67 305 1.5 0.1 2 1.3 10/18/2005 14:00:00 7.3 0.5 8.8 5.7 7.1 0.7 8.4 5.3 63 5 67 305 1.4 0.1 2 1.3 10/18/2005 14:10:00 8.1 0.6 9.5 6.5 8.2 0.7 9.9 6.5 59 5 54 305 1.4 0.1 2 1.3 10/18/2005 14:20:00 8 0.4 9.1 6.8 8.2 0.5 9.5 6.8 53 5 54 305 1.5 0.1 2 1.3 10/18/2005 14:30:00 7.8 0.5 9.1 6.1 7.8 0.6 9.1 6.5 61 4 61 305 1.6 0.1 2.2 1.5 10/18/2005 14:40:00 7.3 0.5 8.4 5.3 7.4 0.6 8.8 4.9 50 8 41 305 1.7 0.2 2.2 1.5 10/18/2005 14:50:00 8.5 0.5 9.5 7.2 8.7 0.6 10.7 6.8 55 5 45 305 1.7 0.1 2.2 1.5 10/18/2005 15:00:00 8.9 0.6 10.7 8 9 0.7 10.7 7.2 56 5 60 305 1.7 0.1 2.2 1.5 10/18/2005 15:10:00 9.3 0.6 10.7 7.6 9.5 0.6 11.1 8 50 3 53 305 1.7 0.2 2.2 1.5 10/18/2005 15:20:00 8.9 0.6 10.3 7.2 9 0.6 10.7 7.2 50 6 51 305 1.8 0.2 2.2 1.5 10/18/2005 15:30:00 9.6 0.9 12.6 7.6 9.7 0.9 12.6 7.6 49 6 50 305 1.7 0.1 2.2 1.5 10/18/2005 15:40:00 9.6 0.7 11.1 7.6 9.6 0.8 11.1 6.8 53 6 56 305 1.7 0.2 2.2 1.5 10/18/2005 15:50:00 9.9 1.1 12.2 7.6 10 1.1 12.2 7.2 52 5 48 305 1.6 0.1 2.2 1.3 10/18/2005 16:00:00 9.9 1.1 11.8 7.2 9.9 1.1 12.2 6.8 46 5 43 305 1.8 0.2 2.2 1.5 10/18/2005 16:10:00 10.4 0.8 12.2 8.8 10.6 0.8 13 8.8 43 4 46 305 1.4 0.2 2.2 1.3 10/18/2005 16:20:00 11.3 1.1 13.3 8 11.2 1.2 13.3 8.4 49 5 45 305 1.6 0.1 2.2 1.3 10/18/2005 16:30:00 11.6 0.8 13.7 9.5 11.7 1 14.1 9.1 47 6 48 305 1.6 0 2.2 1.3 10/18/2005 16:40:00 11.9 0.8 13.3 9.5 12 0.9 13.7 9.5 39 4 41 305 1.6 0.1 2.2 1.3 10/18/2005 16:50:00 12.2 0.7 14.1 10.3 12.3 0.9 14.1 9.9 36 4 32 305 1.6 0 2.2 1.5 10/18/2005 17:00:00 12.1 0.9 14.1 9.5 12.1 0.9 14.5 9.5 34 5 35 305 1.6 0 2.2 1.3 10/18/2005 17:10:00 12.7 0.6 14.1 11.1 12.8 0.7 14.5 10.7 34 4 32 305 1.4 0 2 1.3 10/18/2005 17:20:00 12.3 0.7 13.7 10.3 12.3 0.8 14.1 9.5 31 3 29 305 1.3 0.1 2 1 10/18/2005 17:30:00 12 0.8 13.7 9.1 12.1 1 14.1 8.8 32 4 34 305 1.2 0.1 1.5 1 10/18/2005 17:40:00 11.8 0.8 13.7 9.1 11.8 0.9 14.1 9.5 28 4 25 305 1 0 1.5 0.8 10/18/2005 17:50:00 12.1 0.6 13.7 10.3 12.1 0.7 13.7 9.9 31 3 32 305 0.8 0 1.3 0.6 10/18/2005 18:00:00 12.1 1 14.1 9.1 12 1 14.5 9.1 31 4 25 305 0.7 0.1 1 0.6 10/18/2005 18:10:00 11.9 0.8 13.7 9.5 11.8 0.8 13.7 9.5 29 4 26 305 0.5 0 1.3 0.6 10/18/2005 18:20:00 12.2 0.8 14.1 9.9 12.1 0.8 14.1 9.5 24 4 22 305 0.5 0 0.8 0.3 10/18/2005 18:30:00 12.4 0.6 14.1 10.3 12.3 0.7 13.7 9.9 24 4 23 305 0.5 0 0.6 0.3 10/18/2005 18:40:00 12.4 0.8 14.1 9.9 12.3 0.8 14.1 10.3 22 3 23 305 0.4 0 0.8 0.3 10/18/2005 18:50:00 12.4 0.6 13.7 10.7 12.3 0.8 13.7 10.3 24 3 24 305 0.3 0 0.6 0.1 10/18/2005 19:00:00 12.1 0.8 13.7 9.9 12 0.8 14.1 9.5 21 3 18 305 0.3 0 0.3 0.1 10/18/2005 19:10:00 11.3 0.9 13.7 9.5 11.1 1 13.3 8.8 23 4 21 305 0.2 0 0.8 0.1 10/18/2005 19:20:00 11.5 0.9 13.3 8.8 11.3 0.9 13 8.4 22 4 23 305 0.2 0 0.6 0.1 10/18/2005 19:30:00 11.8 0.7 13.3 9.5 11.6 0.8 13.3 9.1 23 3 20 305 0.1 0 0.3 0.1 10/18/2005 19:40:00 11.2 0.8 13.3 8.8 11 0.8 12.6 7.6 28 4 27 305 0.1 0 0.6 0.1 10/18/2005 19:50:00 11.7 0.8 13.7 9.1 11.4 0.9 13.3 8.8 28 4 26 305 0 0 0.6 0.1 10/18/2005 20:00:00 11.5 1 13.3 8.4 11.2 1.1 13.7 8.4 22 5 32 305 0.2 0 0.3 0.1 10/18/2005 20:10:00 11.4 1 13.3 8.4 11.2 1.1 13.7 8.8 23 3 18 305 0.2 0 0.6 0.1 10/18/2005 20:20:00 11.9 0.8 13.7 9.5 11.7 0.8 13.3 9.9 21 4 17 305 0.3 0 0.8 0.3 10/18/2005 20:30:00 12 0.9 14.1 8.8 11.9 1 14.1 8.4 19 2 22 305 0.4 0 0.8 0.3 10/18/2005 20:40:00 12.4 0.8 14.1 9.9 12.3 0.8 14.1 9.5 18 0 18 305 0.4 0 0.8 0.3 10/18/2005 20:50:00 12.4 0.8 14.1 9.9 12.3 0.8 14.9 9.9 18 0 18 305 0.3 0 0.6 0.3 10/18/2005 21:00:00 11.9 1 13.7 9.5 11.8 1 14.1 9.1 17 0 18 305 0.4 0 0.8 0.3 10/18/2005 21:10:00 11.9 1 14.1 8.8 11.7 1.1 14.5 8.8 15 0 16 305 0.4 0 1 0.3 10/18/2005 21:20:00 11.9 0.9 13.7 9.1 11.9 1 14.1 9.5 14 0 14 305 0.3 0 0.8 0.1 10/18/2005 21:30:00 11.7 0.9 13.3 9.5 11.6 0.9 13.3 9.5 13 2 14 305 0.4 0 1 0.3 10/18/2005 21:40:00 11.6 0.9 13.3 8.4 11.6 1 13.3 8.4 10 0 10 305 0.4 0 0.8 0.3 10/18/2005 21:50:00 10.9 0.8 13 8.8 11 0.9 13 8.8 10 0 10 305 0.3 0 0.6 0.1 10/18/2005 22:00:00 10.3 0.7 11.8 8.4 10.4 0.8 12.2 8 10 0 10 305 0.4 0 0.8 0.3 10/18/2005 22:10:00 11.5 0.8 13.3 9.1 11.6 1 13.7 8.8 9 0 9 305 0.6 0.1 1 0.3 10/18/2005 22:20:00 11.2 0.8 13.7 8.8 11 0.9 13.3 8.8 12 1 10 305 0.5 0 1 0.3 10/18/2005 22:30:00 10.4 0.8 12.2 8 10.5 0.9 12.2 7.6 12 1 13 305 0.5 0 1 0.6 10/18/2005 22:40:00 11 0.9 13 8 11 1 13.3 8 10 1 11 305 0.6 0 1 0.6 10/18/2005 22:50:00 11.4 0.9 13.7 9.1 11.4 0.9 13.7 9.1 12 2 13 305 0.7 0 1 0.6 10/18/2005 23:00:00 11.1 0.9 13 8.8 11 1 13 8.8 15 1 15 305 0.5 0 1 0.3 10/18/2005 23:10:00 11.2 1 13 8.4 11.3 1.1 13.7 7.6 7 5 8 305 0.7 0 1 0.6 10/18/2005 23:20:00 11.9 0.8 14.1 9.1 12.4 0.8 14.1 9.5 1 3 2 305 0.7 0 1.3 0.6 10/18/2005 23:30:00 11.6 0.9 13.3 9.1 12.4 1 14.5 9.1 1 2 358 305 0.7 0 1 0.6 10/18/2005 23:40:00 10.9 1 13 8.4 11.8 1 14.1 8.8 358 4 355 305 0.8 0 1 0.6 10/18/2005 23:50:00 11.7 1 13.7 9.1 12.5 1 14.5 9.5 358 4 359 305 0.9 0 1.3 0.6 10/19/2005 00:00:00 12.1 0.8 14.1 9.5 13 0.8 14.5 10.7 0 4 6 305 0.7 0 1 0.6 10/19/2005 00:10:00 11.9 0.7 13.3 9.5 12.5 0.8 14.5 10.3 2 4 2 305 0.7 0 1 0.6 10/19/2005 00:20:00 11.4 0.8 13.3 9.1 12.2 0.8 14.1 9.5 2 4 359 305 0.7 0 1 0.6 10/19/2005 00:30:00 11.7 1 13.7 8.8 12.3 1 14.5 9.5 2 3 358 305 0.7 0 1 0.6 10/19/2005 00:40:00 11.1 1 13 8.4 11.9 1 13.7 9.1 0 4 359 305 0.7 0 1.3 0.6 10/19/2005 00:50:00 10.9 1 13 8.8 11.8 1 14.9 9.1 359 5 355 305 0.9 0 1.3 0.8 10/19/2005 01:00:00 11.6 1.1 14.1 8.8 12.8 1.1 15.3 10.3 353 3 350 305 1 0 1.3 0.8 10/19/2005 01:10:00 12.2 0.9 14.5 9.5 13.3 1 15.6 10.7 351 4 353 305 1 0 1.5 1 10/19/2005 01:20:00 12 1 14.5 9.1 13.1 1.1 15.6 10.3 350 4 352 305 1 0 1.5 1 10/19/2005 01:30:00 12 0.8 13.7 9.9 13.1 0.9 14.9 10.7 351 4 351 305 1 0 1.5 0.8 10/19/2005 01:40:00 12.1 0.9 14.1 9.5 13 1 15.3 9.9 353 4 354 305 1 0 1.5 0.8 10/19/2005 01:50:00 11.4 1 13.3 8.4 12.4 1.1 14.9 9.1 348 3 346 305 1 0 1.3 0.8 10/19/2005 02:00:00 11.8 1 13.7 9.1 12.8 1.1 15.3 9.5 348 4 346 305 0.9 0 1.3 0.8 10/19/2005 02:10:00 11.9 0.8 13.7 8.8 13 1 15.3 9.5 348 3 347 305 0.9 0 1.5 0.8 10/19/2005 02:20:00 12.1 0.9 14.1 9.9 12.9 1.1 15.3 10.3 349 4 350 305 0.9 0 1.3 0.8 10/19/2005 02:30:00 11.9 0.8 14.1 9.1 12.6 1 14.9 9.5 349 4 352 305 1 0 1.5 0.8 10/19/2005 02:40:00 11.9 0.9 13.7 9.5 12.7 1.1 14.9 9.1 348 4 345 305 0.9 0 1.3 0.8 10/19/2005 02:50:00 11.9 0.8 14.1 9.9 12.6 0.9 14.9 10.3 350 4 352 305 1 0 1.3 0.8 10/19/2005 03:00:00 11.5 0.9 13 8.8 12.3 1 14.1 9.5 348 4 350 305 0.9 0 1 0.8 10/19/2005 03:10:00 11.7 1 13.7 8.8 12.5 1 14.5 9.1 347 4 343 305 0.9 0 1.3 0.8 10/19/2005 03:20:00 12.2 0.8 13.7 9.1 12.9 0.9 15.3 9.9 346 3 344 305 0.9 0 1.3 0.6 10/19/2005 03:30:00 11 0.8 12.6 9.1 11.8 1 14.1 9.1 346 5 342 305 0.9 0 1.3 0.8 10/19/2005 03:40:00 11.1 1 13.3 8 11.9 1.1 14.1 8.4 343 4 343 305 0.9 0 1 0.6 10/19/2005 03:50:00 11.2 0.9 13 8.4 11.8 1 14.1 8.8 341 5 344 305 0.8 0 1 0.6 10/19/2005 04:00:00 11 1 13 8.8 11.6 1 14.1 8.8 339 5 331 305 0.7 0 1 0.6 10/19/2005 04:10:00 11.3 0.8 13.3 9.1 11.9 1 13.7 9.5 338 4 336 305 0.6 0 1 0.6 10/19/2005 04:20:00 11.3 0.7 13.3 9.1 11.9 0.8 13.7 9.5 336 4 335 305 0.6 0 1 0.6 10/19/2005 04:30:00 11 0.7 12.2 9.1 11.5 0.8 13 8.8 334 4 336 305 0.5 0 1 0.6 10/19/2005 04:40:00 11.1 1.1 13 8.8 11.6 1.1 13.7 8.4 336 3 330 305 0.5 0 1 0.3 10/19/2005 04:50:00 11.1 0.9 13 8.4 11.6 1 13.7 9.1 334 4 338 305 0.5 0 0.8 0.3 10/19/2005 05:00:00 11 1 13 8 11.3 1 13.3 8 330 4 328 305 0.4 0 1 0.3 10/19/2005 05:10:00 11 0.8 12.6 8.4 11.5 1 13 8 330 3 330 305 0.4 0 0.8 0.3 10/19/2005 05:20:00 10.8 0.7 12.2 8 11.2 0.8 12.6 8.8 331 3 333 305 0.4 0 0.8 0.3 10/19/2005 05:30:00 10.4 0.8 12.6 8 10.7 0.9 13 8.8 326 5 327 305 0.4 0 1 0.3 10/19/2005 05:40:00 11 0.8 12.2 8.4 11.2 1 12.6 8.4 321 5 315 305 0.2 0 0.6 0.1 10/19/2005 05:50:00 11 0.6 12.2 9.1 11.3 0.8 13 8 320 5 314 305 0.2 0.1 0.6 0.1 10/19/2005 06:00:00 10.3 0.6 11.8 8.4 10.6 0.7 12.2 8.4 324 6 326 305 0.2 0 0.6 0.1 10/19/2005 06:10:00 10.5 0.5 11.8 9.1 10.8 0.6 12.2 8.8 323 4 321 305 0.2 0 0.8 0.1 10/19/2005 06:20:00 9.4 0.6 11.5 7.2 9.6 0.7 11.8 6.8 317 9 310 305 0.3 0 0.8 0.1 10/19/2005 06:30:00 9.4 0.8 11.1 6.8 9.6 0.9 11.5 6.5 315 11 319 305 0.3 0 0.8 0.1 10/19/2005 06:40:00 9 0.6 10.3 7.2 9.3 0.7 11.1 7.2 316 6 311 305 0.4 0.1 1 0.3 10/19/2005 06:50:00 8.2 0.7 9.5 6.1 8.5 0.7 9.9 6.5 319 5 318 305 0.6 0.1 1 0.6 10/19/2005 07:00:00 7.4 0.6 8.8 5.7 7.7 0.7 9.1 5.7 318 6 317 305 0.9 0 1.3 0.6 10/19/2005 07:10:00 7.5 0.9 9.9 5.3 7.5 1 9.9 5.3 304 13 311 305 1 0 1.5 0.8 10/19/2005 07:20:00 7.2 0.8 8.8 4.2 6.9 0.8 8.8 4.2 290 11 288 305 0.9 0 1.3 0.8 10/19/2005 07:30:00 6.7 1 9.1 3.8 5.8 1 8.4 3 281 9 287 305 0.9 0 1.3 0.8 10/19/2005 07:40:00 7.6 0.8 9.1 5.3 6.5 1 8.4 3.8 278 6 283 305 1 0 1 1 10/19/2005 07:50:00 7.2 0.9 8.8 4.6 5.8 0.8 7.6 3.4 275 7 276 305 1 0 1 0.8 10/19/2005 08:00:00 6.8 0.9 8.4 4.2 5.2 0.8 6.8 3.4 270 7 276 305 1 0 1 1 10/19/2005 08:10:00 6.8 0.8 8.8 4.2 5.1 0.7 6.8 2.6 267 7 259 305 1 0 1 1 10/19/2005 08:20:00 6.7 0.9 8.8 3.8 5.3 0.9 7.2 3.4 258 6 262 305 1 0 1.3 1 10/19/2005 08:30:00 7.2 0.8 9.1 4.6 5.9 1 9.1 3.4 257 6 254 305 1 0 1 1 10/19/2005 08:40:00 7.3 0.7 9.1 4.9 5.7 0.7 7.2 3.8 258 6 258 305 1 0 1.3 1 10/19/2005 08:50:00 5.8 1.1 8.4 2.6 4.5 0.9 6.5 2.3 265 8 266 305 1 0 1.3 1 10/19/2005 09:00:00 6.1 0.8 8 3.8 4.6 0.8 6.8 2.6 270 8 273 305 1 0 1 0.8 10/19/2005 09:10:00 6.2 1.1 8 3 4.6 0.9 6.5 1.9 264 8 262 305 0.9 0 1.3 0.8 10/19/2005 09:20:00 6.2 1 8.4 3.4 4.7 0.7 6.5 3 264 7 265 305 0.8 0 1 0.6 10/19/2005 09:30:00 6.2 0.7 7.6 4.6 4.6 0.7 6.5 2.3 268 7 273 305 0.9 0 1.3 0.8 10/19/2005 09:40:00 5.6 0.8 7.6 3.4 4.2 0.7 5.7 2.3 272 7 277 305 1 0 1 0.8 10/19/2005 09:50:00 5.8 0.6 7.6 3.8 4.7 0.7 7.2 3 276 7 284 305 1 0 1.5 0.8 10/19/2005 10:00:00 5.9 0.8 7.2 3.4 4.9 0.9 7.2 2.6 276 6 281 305 0.9 0 1 0.8 10/19/2005 10:10:00 6 0.9 8 4.2 5.3 0.9 6.8 3 279 7 279 305 0.8 0 1.3 0.6 10/19/2005 10:20:00 6.2 0.7 7.6 3.8 4.9 0.8 6.8 3 272 7 276 305 0.7 0 1.3 0.6 10/19/2005 10:30:00 6 0.7 7.6 3.8 4.9 0.7 6.5 3 275 7 276 305 0.8 0 1.3 0.6 10/19/2005 10:40:00 6.8 0.6 8.4 4.6 5.5 0.8 7.6 3.4 274 7 285 305 0.7 0 1.3 0.6 10/19/2005 10:50:00 6.8 0.7 8.8 4.9 5.2 0.6 7.2 3.4 270 6 272 305 0.7 0 1.3 0.6 10/19/2005 11:00:00 6 0.8 8 3.4 4.6 0.7 6.5 2.6 270 7 279 305 0.8 0 1.3 0.8 10/19/2005 11:10:00 6.3 0.9 8.8 3.8 4.8 0.8 7.2 3 265 7 265 305 0.8 0 1.3 0.8 10/19/2005 11:20:00 6.1 0.8 8.4 4.2 4.6 0.7 7.2 3 263 7 266 305 0.9 0 1.5 0.8 10/19/2005 11:30:00 6.5 0.8 7.6 3.8 5.1 0.8 6.8 3 259 7 259 305 0.8 0 1 0.6 10/19/2005 11:40:00 6.3 0.6 7.6 4.9 4.8 0.6 6.5 3 264 7 266 305 0.8 0 1.3 0.6 10/19/2005 11:50:00 5.9 1 8 3.4 4.6 0.8 6.5 2.6 266 8 266 305 0.8 0 1.3 0.6 10/19/2005 12:00:00 6.1 0.8 7.6 3.8 5 0.9 7.6 2.6 259 7 263 305 0.8 0 1.3 0.6 10/19/2005 12:10:00 5.7 1 7.6 3.4 4.6 0.8 6.8 2.6 268 7 265 305 1 0 1.3 0.8 10/19/2005 12:20:00 5.3 0.8 8 3.4 4.3 0.8 6.5 2.3 267 10 274 305 1.2 0.1 1.7 1 10/19/2005 12:30:00 5.7 1 7.6 3.4 4.5 0.8 6.8 2.6 264 7 275 305 1.1 0.1 1.5 1 10/19/2005 12:40:00 5.9 0.7 7.6 3.8 4.7 0.7 6.5 2.6 264 6 272 305 1.1 0.1 1.5 1 10/19/2005 12:50:00 5.2 1.1 8 3.4 4.1 1 6.8 2.3 262 7 259 305 1.1 0.1 1.5 1 10/19/2005 13:00:00 5.5 0.8 8 3.4 4.7 0.8 7.6 2.3 257 9 255 305 1 0 1.5 1 10/19/2005 13:10:00 5.6 1 8.4 3 4.6 1 7.2 2.3 258 8 261 305 1 0.1 1.5 1 10/19/2005 13:20:00 5.7 1.1 8 3 4.7 1.1 7.6 2.6 258 7 258 305 1.2 0.1 1.7 1 10/19/2005 13:30:00 5.7 0.9 8 4.2 5 1 6.8 2.6 254 8 256 305 1.2 0.1 1.7 1 10/19/2005 13:40:00 5.4 0.7 7.6 3.4 4.7 0.9 7.2 2.6 250 7 250 305 1.6 0.2 2.2 1.3 10/19/2005 13:50:00 6.1 0.7 8 4.2 5.5 0.8 7.2 3 250 8 259 305 1.6 0.1 2.2 1.3 10/19/2005 14:00:00 5.5 0.9 7.2 3 4.9 1 7.2 2.6 252 7 253 305 1.6 0.2 2.2 1.3 10/19/2005 14:10:00 6.2 0.7 7.6 4.2 5.7 0.8 7.2 3.4 246 6 242 305 1.7 0.1 2.2 1.5 10/19/2005 14:20:00 6.1 0.6 7.6 4.2 5.7 0.8 7.2 3.4 245 5 249 305 1.8 0.1 2.2 1.5 10/19/2005 14:30:00 6.2 0.9 8 4.2 5.8 1 8 3.4 247 7 241 305 1.9 0 2.2 1.5 10/19/2005 14:40:00 6.7 0.8 8.4 4.6 6.2 0.8 8.4 4.2 243 6 240 305 1.9 0.1 2.5 2 10/19/2005 14:50:00 6.4 0.6 8 4.6 5.9 0.8 7.6 4.2 243 6 242 305 2.1 0.1 2.5 2 10/19/2005 15:00:00 6.6 0.8 8.8 3.8 6 0.9 8 3.4 245 7 248 305 2.2 0.1 2.7 2 10/19/2005 15:10:00 7.4 0.5 8.8 5.7 6.9 0.7 8.4 5.3 246 5 246 305 2 0.2 2.5 1.7 10/19/2005 15:20:00 6.9 0.8 8.4 4.6 6.5 0.8 8.8 3.8 244 6 242 305 1.8 0.2 2.2 1.5 10/19/2005 15:30:00 6.8 0.7 8.8 4.9 6.3 0.8 8.4 4.2 240 5 234 305 1.7 0.1 2.2 1.5 10/19/2005 15:40:00 6.6 0.6 8 4.6 6.1 0.7 8 4.2 240 5 239 305 1.7 0.1 2.2 1.5 10/19/2005 15:50:00 6.8 0.7 8.4 4.6 6.4 0.8 8 4.2 238 5 238 305 1.7 0.1 2.2 1.5 10/19/2005 16:00:00 6.4 0.6 8.4 4.2 6 0.7 8 3.8 236 6 244 305 1.7 0.1 2.2 1.5 10/19/2005 16:10:00 6.4 0.4 7.6 5.3 6.1 0.5 7.2 4.6 228 4 225 305 1.9 0.1 2.2 1.5 10/19/2005 16:20:00 6.5 0.5 8 4.6 6.2 0.6 7.6 4.2 228 5 228 305 1.9 0 2.2 1.7 10/19/2005 16:30:00 6.9 0.5 8 5.3 6.4 0.6 7.6 4.6 230 5 226 305 1.9 0 2.5 2 10/19/2005 16:40:00 7.5 0.6 8.8 6.1 7.1 0.7 8.4 5.3 227 4 225 305 1.8 0.2 2.5 1.5 10/19/2005 16:50:00 7 0.6 8.4 4.9 6.6 0.7 8 4.6 224 5 230 305 1.9 0.1 2.2 1.7 10/19/2005 17:00:00 6.9 0.7 8.4 4.9 6.5 0.8 8 4.6 230 5 231 305 1.9 0.1 2.2 1.5 10/19/2005 17:10:00 6.7 0.6 8 4.9 6.4 0.7 7.6 4.2 225 7 229 305 1.9 0.1 2.2 1.5 10/19/2005 17:20:00 6.2 0.8 8 3.8 5.9 0.9 7.6 3.8 223 6 223 305 1.8 0.1 2.2 1.5 10/19/2005 17:30:00 6.4 0.6 8 4.6 6.1 0.8 8 4.2 225 6 224 305 1.9 0 2.5 1.7 10/19/2005 17:40:00 6.9 0.8 9.1 4.9 6.6 0.8 8.8 4.6 228 6 231 305 1.9 0.1 2.2 1.7 10/19/2005 17:50:00 6.8 1 8.8 4.6 6.3 1.1 8.8 3.8 232 5 238 305 1.4 0.2 2.2 1.3 10/19/2005 18:00:00 6.3 0.7 7.6 4.2 5.8 0.8 7.6 3.4 227 5 224 305 1.6 0.2 2.2 1.3 10/19/2005 18:10:00 6.8 0.5 7.6 5.3 6.4 0.6 7.6 4.9 222 5 227 305 1.7 0.1 2.2 1.5 10/19/2005 18:20:00 6.7 0.5 8 4.9 6.2 0.6 7.6 4.6 220 5 222 305 1.7 0.1 2.2 1.5 10/19/2005 18:30:00 6.2 0.6 7.6 4.6 5.9 0.6 7.6 4.2 220 5 218 305 1.6 0.1 2.2 1.5 10/19/2005 18:40:00 6.2 0.6 7.2 4.2 5.8 0.7 7.2 4.2 219 5 217 305 1.6 0 2.2 1.5 10/19/2005 18:50:00 6.2 0.6 7.6 4.2 5.8 0.7 7.2 3.8 226 5 235 305 1.7 0.2 2.2 1.5 10/19/2005 19:00:00 6.6 0.7 8 4.6 6.2 0.8 7.6 3.8 225 6 228 305 1.7 0.2 2.2 1.5 10/19/2005 19:10:00 6 0.7 7.2 4.2 5.5 0.8 7.2 3.8 221 5 211 305 1.8 0.2 2.2 1.5 10/19/2005 19:20:00 7.2 0.7 9.1 5.3 6.8 0.8 8.8 4.9 233 10 232 305 1.9 0.1 2.5 1.7 10/19/2005 19:30:00 6.6 0.6 8 4.9 6.1 0.8 7.6 4.2 239 7 241 305 1.8 0.1 2.5 1.5 10/19/2005 19:40:00 6.4 0.5 7.6 4.9 5.9 0.6 7.2 4.6 232 5 236 305 1.9 0.1 2.5 1.5 10/19/2005 19:50:00 6 0.7 7.6 4.2 5.6 0.7 7.2 3.8 231 5 228 305 1.9 0.1 2.5 1.7 10/19/2005 20:00:00 5.8 0.5 6.8 4.6 5.5 0.5 6.5 3.8 226 5 227 305 1.9 0.1 2.5 1.7 10/19/2005 20:10:00 5.9 0.5 7.2 4.2 5.5 0.6 6.8 3.8 224 5 224 305 2 0.2 2.5 2 10/19/2005 20:20:00 5.9 0.7 7.6 4.2 5.5 0.7 7.2 3.8 229 6 230 305 2 0.1 2.5 2 10/19/2005 20:30:00 6.3 0.7 7.6 4.2 5.8 0.7 7.2 3.8 232 5 230 305 2.2 0.1 2.7 2 10/19/2005 20:40:00 5.9 0.6 8 4.2 5.5 0.6 7.6 3.8 228 5 223 305 2.2 0.1 2.7 2 10/19/2005 20:50:00 6.4 0.5 7.6 4.6 6.1 0.6 7.2 4.2 227 4 222 305 2.2 0.1 2.7 2 10/19/2005 21:00:00 6.3 0.5 7.6 4.9 5.9 0.7 7.6 3.8 223 3 221 305 2.2 0.1 2.5 2 10/19/2005 21:10:00 5.9 0.5 7.2 4.6 5.5 0.5 6.8 4.2 219 5 220 305 2.2 0.1 2.7 2 10/19/2005 21:20:00 6.4 0.7 8 4.2 6 0.8 7.6 4.2 222 5 224 305 2.2 0.1 2.7 2 10/19/2005 21:30:00 6.7 0.8 9.1 4.9 6.2 0.8 9.1 4.6 225 6 236 305 2.2 0.1 2.7 2.2 10/19/2005 21:40:00 7.9 1.1 9.9 4.6 7.5 1.1 9.9 4.2 243 5 239 305 1.8 0.2 2.5 1.5 10/19/2005 21:50:00 7.2 0.6 8.8 5.3 6.9 0.7 8.8 4.6 242 3 242 305 1.6 0.1 2.2 1.5 10/19/2005 22:00:00 5.6 0.7 7.6 3.8 5.3 0.8 7.6 3 247 6 247 305 1.6 0.1 2.2 1.5 10/19/2005 22:10:00 4.9 0.7 6.8 3 4.6 0.8 6.5 3 241 8 247 305 1.6 0.1 2 1.5 10/19/2005 22:20:00 4.7 0.4 5.7 3.4 4.5 0.5 5.7 3 234 7 244 305 1.5 0.1 2 1.3 10/19/2005 22:30:00 4.8 0.5 5.7 3.4 4.7 0.5 5.7 3 227 4 225 305 1.4 0.1 2 1.3 10/19/2005 22:40:00 5.1 0.5 6.5 3.8 5 0.6 6.1 3.4 227 4 231 305 1.6 0 2.2 1.3 10/19/2005 22:50:00 6.1 0.8 8.4 4.2 5.8 0.7 8 4.2 227 6 218 305 1.6 0 2.2 1.5 10/19/2005 23:00:00 6 0.8 7.6 3.8 5.8 0.8 7.2 3.4 227 5 229 305 1.6 0 2.2 1.5 10/19/2005 23:10:00 6.6 0.6 8 4.6 6.1 0.7 7.6 4.2 233 5 237 305 1.7 0.1 2.2 1.5 10/19/2005 23:20:00 7.1 0.8 9.1 4.9 6.7 0.8 8.8 4.6 230 5 231 305 1.7 0 2.2 1.5 10/19/2005 23:30:00 6.1 0.7 8 4.2 6 0.6 7.6 4.2 218 5 221 305 1.4 0 1.7 1.3 10/19/2005 23:40:00 6.4 1.1 8.8 4.2 6.2 1.1 8.4 3.8 235 9 242 305 1.6 0 2 1.3 10/19/2005 23:50:00 5.3 0.4 6.5 4.2 5.1 0.5 6.1 3.8 231 4 234 305 1.3 0 2 1.3 10/20/2005 00:00:00 5.5 0.5 7.2 3.8 5.4 0.6 6.5 3.8 232 3 234 305 1.4 0 1.7 1.3 10/20/2005 00:10:00 5.8 0.5 6.8 4.2 5.6 0.6 6.8 3.8 232 4 238 305 1.6 0 2 1.5 10/20/2005 00:20:00 5.8 0.6 7.6 4.2 5.6 0.7 7.2 3.8 229 5 226 305 1.6 0 2 1.5 10/20/2005 00:30:00 7.1 0.6 8.4 4.9 6.7 0.8 8.4 3.8 235 10 252 305 1.6 0 2 1.5 10/20/2005 00:40:00 6.4 0.6 8.4 4.9 6 0.7 8 4.2 240 7 238 305 1.4 0 2 1.3 10/20/2005 00:50:00 7.2 0.7 8.8 4.9 6.8 0.7 8 4.9 237 5 243 305 1.6 0 2 1.5 10/20/2005 01:00:00 6.4 0.6 7.6 4.6 5.9 0.6 7.2 4.2 231 5 228 305 1.3 0 1.7 1.3 10/20/2005 01:10:00 6.7 0.6 8 4.6 6.2 0.7 7.6 4.6 233 5 236 305 1.3 0 1.7 1.3 10/20/2005 01:20:00 6.6 0.6 7.6 4.9 6.1 0.6 7.6 4.6 233 4 237 305 1.4 0 2 1.3 10/20/2005 01:30:00 6.6 0.9 8.8 4.6 6.3 1 9.1 3.8 230 6 237 305 1.6 0 2 1.3 10/20/2005 01:40:00 6.8 0.8 8.4 4.6 6.5 0.8 8.4 4.2 232 5 230 305 1.6 0 2.2 1.5 10/20/2005 01:50:00 6.6 0.7 8.8 4.9 6.3 0.8 8.4 4.2 232 6 238 305 1.6 0 2.2 1.5 10/20/2005 02:00:00 5.8 0.6 7.2 3.8 5.4 0.7 7.2 3.4 234 8 228 305 1.6 0 2.2 1.5 10/20/2005 02:10:00 6.6 0.7 8 4.6 6.2 0.7 8 4.6 225 6 224 305 1.6 0 2.2 1.5 10/20/2005 02:20:00 6.9 0.8 8.4 4.6 6.6 0.8 8.4 4.6 227 5 230 305 1.7 0 2.2 1.5 10/20/2005 02:30:00 7.3 0.6 8.8 4.9 6.8 0.7 8.4 4.9 226 5 230 305 1.7 0 2.2 1.5 10/20/2005 02:40:00 7.3 0.7 8.8 4.9 6.9 0.8 8.4 4.6 224 5 219 305 1.7 0 2.2 1.5 10/20/2005 02:50:00 6.9 0.7 8.4 4.9 6.6 0.8 8.4 4.2 220 5 221 305 1.6 0 2.2 1.5 10/20/2005 03:00:00 7.5 1 10.3 5.3 7.1 1.1 9.9 4.6 221 8 231 305 1.6 0 2 1.5 10/20/2005 03:10:00 7 0.8 9.1 4.9 6.6 0.9 8.8 3.8 221 11 237 305 1.3 0 2 1.3 10/20/2005 03:20:00 6.5 0.5 8 4.6 6.3 0.6 7.6 4.6 208 5 210 305 1.2 0 1.7 1 10/20/2005 03:30:00 5.8 0.7 7.2 3.8 5.6 0.8 7.2 3.4 210 5 210 305 1.4 0 2 1.3 10/20/2005 03:40:00 6.1 0.6 7.2 4.6 5.8 0.7 7.2 3.8 210 7 210 305 1.6 0 2 1.5 10/20/2005 03:50:00 7.9 0.8 9.5 4.9 7.6 1 9.5 4.9 225 4 223 305 1.8 0 2.2 1.5 10/20/2005 04:00:00 6.8 0.9 9.1 4.2 6.6 1 8.8 4.2 227 5 230 305 1.6 0 2.2 1.5 10/20/2005 04:10:00 6.8 0.7 8.8 4.6 6.7 0.8 8.4 4.6 216 5 213 305 1.7 0.1 2.2 1.5 10/20/2005 04:20:00 6.4 0.6 8.4 4.2 6.1 0.7 8 4.2 218 5 222 305 1.7 0.1 2.2 1.5 10/20/2005 04:30:00 6.1 0.5 7.2 4.2 5.9 0.6 7.6 4.2 211 6 211 305 1.6 0 2.2 1.5 10/20/2005 04:40:00 6.3 0.8 8.8 4.2 6.1 0.8 7.6 4.2 213 8 211 305 1.7 0.1 2.2 1.5 10/20/2005 04:50:00 6.2 0.8 8.4 4.2 6 0.8 8 4.2 214 5 212 305 1.9 0 2.2 1.5 10/20/2005 05:00:00 7.2 0.5 8.4 5.3 6.8 0.6 8.8 5.3 215 6 205 305 1.9 0 2.2 1.7 10/20/2005 05:10:00 7.5 0.7 9.1 5.7 7.2 0.8 9.1 4.9 215 5 198 305 1.9 0 2.2 1.7 10/20/2005 05:20:00 6.9 0.8 8.8 4.9 6.6 0.8 8.8 4.6 221 6 218 305 1.8 0 2.2 1.5 10/20/2005 05:30:00 6.4 1 8.4 4.2 6.1 1 8.4 4.2 220 5 221 305 1.9 0 2.5 1.7 10/20/2005 05:40:00 7.5 0.7 9.1 5.7 7.1 0.8 9.1 4.9 223 5 219 305 2.1 0 2.7 2 10/20/2005 05:50:00 8 0.8 9.9 5.7 7.4 0.8 9.5 4.9 230 7 239 305 2.1 0 2.7 2 10/20/2005 06:00:00 8.4 0.9 10.3 6.1 7.8 0.9 9.9 5.3 232 7 234 305 2 0.2 2.7 1.5 10/20/2005 06:10:00 8.9 1.3 11.8 6.5 8.4 1.2 11.8 5.7 227 5 229 305 1.7 0.1 2.2 1.5 10/20/2005 06:20:00 10.7 0.9 13.3 7.6 9.9 1.1 13.3 6.8 230 5 236 305 1.7 0.1 2.2 1.5 10/20/2005 06:30:00 10.4 1.1 12.6 6.8 9.8 1.2 12.2 6.8 227 5 226 305 1.7 0.1 2.2 1.5 10/20/2005 06:40:00 10.8 1.3 13.3 6.8 10.1 1.3 13 7.2 231 5 228 305 1.6 0 2.2 1.5 10/20/2005 06:50:00 10 1 12.2 7.2 9.2 1 12.2 6.8 231 5 237 305 1.8 0.1 2.5 1.5 10/20/2005 07:00:00 9.7 1.1 12.6 6.5 9.1 1.1 11.8 6.1 235 5 245 305 1.7 0.1 2.2 1.5 10/20/2005 07:10:00 10.3 1.1 13 6.5 9.5 1.2 12.2 6.5 235 6 234 305 2 0.1 2.7 1.7 10/20/2005 07:20:00 10.9 1.2 14.1 8 10.2 1.3 13.7 6.5 238 6 242 305 2.1 0 2.7 2 10/20/2005 07:30:00 12.4 1 14.5 8.8 11.7 1.1 14.5 8.4 239 5 244 305 1.9 0.2 2.5 1.5 10/20/2005 07:40:00 11.4 1.3 14.1 7.2 10.7 1.5 14.1 6.5 241 6 244 305 1.8 0.1 2.5 1.5 10/20/2005 07:50:00 12 1.2 15.3 7.6 11.3 1.4 14.5 7.2 241 6 242 305 2 0.1 2.7 1.7 10/20/2005 08:00:00 11.7 1.4 15.3 8.4 10.9 1.5 14.9 8 239 6 241 305 2.2 0.1 2.7 2 10/20/2005 08:10:00 12 1.5 14.9 8 11.2 1.5 14.1 6.8 241 6 237 305 2.3 0.2 2.9 2.2 10/20/2005 08:20:00 13 1.5 16.4 8 12.3 1.7 16.1 6.8 247 6 239 305 2.2 0.1 2.7 2 10/20/2005 08:30:00 11.4 1.4 15.3 8 10.7 1.4 14.5 6.8 243 7 250 305 2.3 0.1 2.9 2.2 10/20/2005 08:40:00 11.7 1.5 16.1 6.8 11 1.6 16.1 6.5 245 7 243 305 2.3 0.2 2.9 2 10/20/2005 08:50:00 12.4 1.7 16.8 8.8 11.5 1.8 16.8 8 244 6 254 305 2.2 0.1 2.7 2 10/20/2005 09:00:00 12.6 1.4 16.4 8.8 11.7 1.5 16.4 7.6 241 6 242 305 2.2 0.1 2.7 2 10/20/2005 09:10:00 13.3 1.6 16.4 8.4 12.3 1.7 16.8 8 241 5 234 305 2.2 0.1 2.7 2 10/20/2005 09:20:00 14.5 1.5 17.9 9.9 13.7 1.7 17.2 8.8 244 5 245 305 2.2 0.1 2.7 2 10/20/2005 09:30:00 13.4 1.5 16.4 9.9 12.5 1.6 16.1 8 241 6 246 305 2.3 0.1 2.9 2.2 10/20/2005 09:40:00 13.9 1.8 17.6 9.5 12.8 1.9 16.8 8.8 240 7 243 305 2.3 0.2 2.9 2.2 10/20/2005 09:50:00 14.2 1.4 17.6 10.3 13.2 1.6 16.4 8.8 240 6 239 305 2.2 0.1 2.7 2 10/20/2005 10:00:00 14.1 1.4 17.2 10.7 13.1 1.5 16.8 8.8 240 5 243 305 2 0.1 2.7 2 10/20/2005 10:10:00 14 1.7 17.2 8.4 13 1.8 16.8 7.6 240 6 244 305 2.1 0.1 2.5 2 10/20/2005 10:20:00 14.4 1.5 17.9 10.7 13.5 1.7 17.6 9.5 238 5 235 305 1.9 0.2 2.5 1.5 10/20/2005 10:30:00 14.2 1.5 17.6 9.9 13.3 1.4 16.8 9.5 236 5 239 305 2 0.2 2.5 1.7 10/20/2005 10:40:00 13.8 1.4 16.8 9.9 12.9 1.5 16.1 9.5 236 5 239 305 1.9 0.1 2.5 1.7 10/20/2005 10:50:00 13.7 1.9 17.6 8 12.7 1.8 17.2 8 235 6 239 305 1.8 0.2 2.5 1.5 10/20/2005 11:00:00 13.8 1.7 17.2 9.5 12.9 1.7 16.8 8.8 235 7 242 305 1.6 0 2.2 1.5 10/20/2005 11:10:00 14.2 1.2 17.2 11.1 13.2 1.3 16.4 9.1 233 5 231 305 1.6 0 2.2 1.5 10/20/2005 11:20:00 13.5 1.5 16.4 9.9 12.7 1.6 16.4 8.8 235 5 234 305 1.6 0 2.2 1.5 10/20/2005 11:30:00 13.7 1.5 16.4 9.9 12.9 1.5 16.4 8.8 236 6 232 305 1.9 0.1 2.5 1.5 10/20/2005 11:40:00 13.7 1.7 17.2 9.1 12.7 1.7 16.1 8 239 6 238 305 2 0 2.5 2 10/20/2005 11:50:00 13.1 1.5 16.4 8.4 12.2 1.5 15.6 8 239 6 244 305 2.1 0.2 2.7 2 10/20/2005 12:00:00 14.3 1.7 17.9 9.9 13.5 1.8 17.6 9.1 243 6 246 305 2.2 0.2 2.7 2 10/20/2005 12:10:00 14.5 1.4 17.6 9.1 13.6 1.6 17.6 9.5 240 5 230 305 1.9 0.2 2.5 1.5 10/20/2005 12:20:00 14.4 1.5 17.6 10.7 13.4 1.5 16.8 9.1 241 6 251 305 1.7 0.2 2.2 1.5 10/20/2005 12:30:00 15 1.7 17.9 10.3 14 1.7 17.2 9.1 242 6 238 305 1.6 0.1 2.2 1.5 10/20/2005 12:40:00 14.3 1.8 18.7 9.9 13.4 1.9 17.6 8 242 6 246 305 1.6 0.1 2.2 1.5 10/20/2005 12:50:00 14.3 1.7 17.6 8.8 13.4 1.8 17.6 8.8 244 6 248 305 1.8 0.2 2.5 1.5 10/20/2005 13:00:00 14 1.8 18.3 9.5 13.1 1.9 17.2 8.8 244 6 247 305 1.9 0.1 2.5 2 10/20/2005 13:10:00 12.9 1.4 16.4 8.8 11.9 1.5 16.1 8.4 244 7 246 305 2 0.1 2.5 2 10/20/2005 13:20:00 12.9 1.7 16.1 8.4 12.1 1.7 16.8 7.2 244 6 239 305 2 0.1 2.5 2 10/20/2005 13:30:00 13.6 1.5 16.4 8.8 12.9 1.7 16.4 8.4 245 6 244 305 2 0.1 2.5 2 10/20/2005 13:40:00 12.9 1.5 16.4 8.8 12 1.7 15.3 8 244 6 250 305 2.2 0.1 2.7 2 10/20/2005 13:50:00 13.7 1.5 17.2 9.1 12.8 1.7 16.4 7.6 243 6 247 305 2.2 0.1 2.7 2 10/20/2005 14:00:00 12.9 1.3 16.1 9.1 12.2 1.4 14.9 8.8 240 6 228 305 2.2 0.1 2.7 2 10/20/2005 14:10:00 13.1 1.5 16.4 8 12.1 1.6 15.6 7.2 238 6 242 305 1.9 0.2 2.5 1.5 10/20/2005 14:20:00 13.1 1.5 16.8 9.1 12.2 1.6 16.1 8.4 239 5 244 305 1.7 0.2 2.2 1.5 10/20/2005 14:30:00 13 1.3 15.6 8.8 12.2 1.5 14.9 8 239 6 241 305 1.7 0.2 2.2 1.5 10/20/2005 14:40:00 13 1.3 15.6 8.8 12.1 1.4 14.9 7.6 240 5 239 305 1.7 0.1 2.2 1.5 10/20/2005 14:50:00 13.3 1.1 15.6 9.1 12.3 1.3 14.9 8.4 239 6 232 305 1.7 0.1 2.2 1.5 10/20/2005 15:00:00 13.7 1.4 16.8 10.3 12.8 1.5 16.4 9.5 237 5 239 305 1.5 0.2 2.2 1.3 10/20/2005 15:10:00 13.3 1.3 16.4 8.8 12.4 1.5 15.6 8.8 239 5 242 305 1.6 0.2 2.2 1.3 10/20/2005 15:20:00 11.9 1.4 14.9 8.4 11 1.5 14.5 7.6 239 7 240 305 1.7 0.2 2.2 1.5 10/20/2005 15:30:00 12.6 1.2 14.9 8.8 11.7 1.3 14.5 8.4 233 5 239 305 1.7 0.2 2.2 1.5 10/20/2005 15:40:00 12.7 1.3 15.3 9.1 11.9 1.3 14.9 8.4 233 6 227 305 1.6 0.1 2.2 1.5 10/20/2005 15:50:00 12.5 1.3 15.6 9.1 11.7 1.3 14.9 8.8 233 6 231 305 1.5 0 2 1.3 10/20/2005 16:00:00 12.2 1.5 15.3 7.2 11.6 1.5 14.5 7.2 230 5 229 305 1.4 0.1 2 1.3 10/20/2005 16:10:00 11.6 1.2 14.9 8 10.9 1.2 14.1 7.6 230 6 232 305 1.3 0.1 1.7 1.3 10/20/2005 16:20:00 11.7 1.2 14.9 7.6 11.2 1.3 14.5 8 228 5 223 305 1.2 0.1 1.7 1 10/20/2005 16:30:00 12.2 1.2 14.5 8.4 11.5 1.3 14.1 8.4 226 5 231 305 1.1 0 1.5 1 10/20/2005 16:40:00 11.2 1.3 14.5 7.6 10.4 1.3 13.7 7.6 227 6 224 305 1.1 0.1 1.5 1 10/20/2005 16:50:00 11.1 1.4 14.9 7.2 10.4 1.3 14.5 6.8 237 6 241 305 1.1 0.1 1.5 1 10/20/2005 17:00:00 9.5 1.1 11.8 6.5 8.9 1.2 11.5 5.3 236 6 232 305 1.2 0.2 1.7 1 10/20/2005 17:10:00 9.5 1.1 11.8 6.5 9 1.1 11.5 6.5 234 7 237 305 1.3 0.2 1.7 1 10/20/2005 17:20:00 10.3 1.2 13 7.2 9.5 1.2 12.6 6.8 222 5 224 305 1.4 0.1 2 1.3 10/20/2005 17:30:00 10.8 0.9 13.3 8.4 10.3 1 13 7.2 227 6 224 305 1.3 0.2 2 1 10/20/2005 17:40:00 9.3 1.1 12.2 6.8 8.9 1 11.5 6.1 226 8 232 305 1.3 0.2 1.7 1.3 10/20/2005 17:50:00 9.8 1.2 13 6.1 9.4 1.2 13 6.1 219 6 230 305 1.3 0.1 2 1 10/20/2005 18:00:00 9.2 0.9 11.1 6.8 8.7 1 11.1 6.5 223 7 225 305 1.2 0.1 1.5 1 10/20/2005 18:10:00 8.2 1 10.7 5.7 7.8 0.9 9.9 5.3 227 6 231 305 1.2 0.1 1.5 1 10/20/2005 18:20:00 7.9 0.8 9.9 5.7 7.6 1 10.3 4.9 218 7 208 305 1.2 0.1 1.5 1 10/20/2005 18:30:00 8.2 1 10.3 6.1 7.8 1 10.3 5.3 224 6 224 305 1.3 0.1 1.7 1.3 10/20/2005 18:40:00 6.9 0.7 8.4 4.6 6.6 0.7 8.4 4.2 219 5 220 305 1.3 0 1.5 1 10/20/2005 18:50:00 6.9 0.7 8.8 4.9 6.7 0.7 8.4 4.9 216 5 214 305 1.4 0 2 1.3 10/20/2005 19:00:00 6.2 1 9.1 3.8 6 1 9.1 3.8 206 8 189 305 1.5 0 2 1.3 10/20/2005 19:10:00 7.4 0.7 9.1 4.9 7.2 0.8 9.1 4.6 203 6 203 305 1.6 0 2.2 1.5 10/20/2005 19:20:00 6.3 1.3 8.4 3 6.6 1 8.8 3.8 175 21 203 305 1.6 0.2 2.2 1.3 10/20/2005 19:30:00 5.6 1.2 8.4 3 6.6 0.7 8.8 4.2 163 13 147 305 1.1 0.1 1.5 0.8 10/20/2005 19:40:00 5.7 1.2 8 3 7 0.9 9.1 4.9 176 6 182 305 1.3 0 1.7 1.3 10/20/2005 19:50:00 6.9 0.6 8.4 3.8 7.3 0.5 8.8 5.3 183 3 179 305 1.2 0.1 1.5 1 10/20/2005 20:00:00 6.6 0.4 7.6 4.9 6.9 0.3 7.6 6.1 183 2 186 305 1 0 1.5 1 10/20/2005 20:10:00 5.3 1 7.2 2.6 7 0.9 9.1 4.9 173 7 183 305 1.3 0 2 1 10/20/2005 20:20:00 5.8 1.4 9.1 3 7.3 1 9.9 4.6 173 7 186 305 1.4 0 2 1.3 10/20/2005 20:30:00 7 1.3 9.9 4.2 8.6 0.9 10.7 6.1 177 5 182 305 1.4 0 2 1.3 10/20/2005 20:40:00 7.3 1.6 12.6 4.2 9.6 1 12.2 6.5 174 7 188 305 1.2 0.1 2 1 10/20/2005 20:50:00 8.7 1.2 11.1 4.9 9.8 0.8 12.2 7.2 180 4 183 305 1.2 0.1 1.7 1 10/20/2005 21:00:00 7.7 1.2 9.9 3.4 9.1 0.8 11.1 6.8 178 4 177 305 1.3 0 1.7 1.3 10/20/2005 21:10:00 6.8 1.3 10.7 4.2 8.9 0.9 12.2 6.1 174 6 184 305 1.4 0 2 1.3 10/20/2005 21:20:00 6.3 1 9.1 4.2 9.2 0.9 11.5 6.8 169 6 168 305 1.5 0 2 1.3 10/20/2005 21:30:00 5.4 0.9 7.6 3.4 7.8 1 9.9 5.3 166 5 157 305 1 0 1.5 0.6 10/20/2005 21:40:00 6.4 1.2 10.7 4.2 8.2 0.9 11.1 5.7 164 9 145 305 0.2 0.2 1 -0.1 10/20/2005 21:50:00 7 1.5 11.1 3.4 7.3 1.1 10.3 4.6 151 10 151 305 -0.3 0 0.1 -0.4 10/20/2005 22:00:00 7.6 1.4 11.1 3.8 7.6 1.2 11.1 4.6 148 10 155 305 -0.1 0 0.3 -0.4 10/20/2005 22:10:00 8.6 1.6 12.2 3.8 8.5 1.5 11.8 5.3 146 10 149 305 0.2 0 0.6 0.1 10/20/2005 22:20:00 9 1.8 13.3 4.2 9.1 1.6 13.3 4.9 145 11 155 305 0.4 0 0.8 0.1 10/20/2005 22:30:00 9.5 1.5 12.6 4.2 9.4 1.4 12.6 6.1 143 10 150 305 0.4 0 0.8 0.3 10/20/2005 22:40:00 11.3 1.6 15.3 6.8 11.1 1.5 15.3 6.8 144 9 145 305 0.5 0 1 0.3 10/20/2005 22:50:00 11.1 1.4 14.9 7.2 10.8 1.3 14.1 8 146 8 158 305 0.6 0.1 1 0.3 10/20/2005 23:00:00 11.7 1.6 15.3 6.8 11.3 1.5 14.9 6.8 146 7 140 305 0.5 0 1 0.6 10/20/2005 23:10:00 11.3 1.3 14.1 8 11 1.2 14.1 8 146 7 147 305 0.6 0.1 1 0.6 10/20/2005 23:20:00 11.3 1.1 13.7 7.2 11 1.1 13.7 7.2 144 7 147 305 0.5 0 1 0.6 10/20/2005 23:30:00 10.8 1.1 13.3 7.6 10.5 1 13 7.6 144 8 144 305 0.6 0.1 1 0.6 10/20/2005 23:40:00 10.8 0.9 13.7 8.4 10.5 0.8 13.3 8 147 6 150 305 0.7 0.1 1.3 0.6 10/20/2005 23:50:00 11 0.9 13.3 8 10.6 1 13 7.6 147 5 150 305 0.9 0 1.3 0.6 10/21/2005 00:00:00 10.7 0.8 12.6 8.4 10.3 0.8 12.2 8 147 4 150 305 0.9 0 1.3 0.8 10/21/2005 00:10:00 10 0.8 11.8 8 9.7 0.7 11.8 7.6 146 4 148 305 1 0 1.5 0.8 10/21/2005 00:20:00 9.3 1.2 12.2 5.7 9.1 1 11.5 6.5 147 6 151 305 1.1 0 1.5 1 10/21/2005 00:30:00 6.1 1.3 9.5 3.8 8.1 1 10.3 5.7 167 9 154 305 1.2 0.1 1.5 1 10/21/2005 00:40:00 6 1.3 9.5 3.4 7.6 0.8 9.1 5.7 176 6 179 305 1.6 0 1.5 1.3 10/21/2005 00:50:00 4.4 1 6.8 2.3 5.4 0.8 8 3.4 166 11 177 305 1.2 0.2 2 0.8 10/21/2005 01:00:00 5.8 1.6 9.1 1.9 6.3 1.4 9.9 3.4 167 15 185 305 0.6 0.1 1 0.6 10/21/2005 01:10:00 8.1 0.3 9.1 7.2 8.3 0.3 9.9 7.2 185 2 189 305 1.2 0.1 1.5 1 10/21/2005 01:20:00 8.7 0.6 9.5 5.3 9.1 0.5 9.9 7.6 183 3 186 305 1.2 0 1.5 1 10/21/2005 01:30:00 9 0.2 9.5 8.4 9.4 0.2 9.9 8.8 186 1 186 305 1.5 0 2 1.3 10/21/2005 01:40:00 8.5 0.4 9.1 7.6 8.8 0.5 9.9 7.2 187 1 187 305 1.5 0 2 1.5 10/21/2005 01:50:00 8.4 0.3 9.1 7.6 8.5 0.4 9.5 7.2 186 3 191 305 1.5 0 2 1.3 10/21/2005 02:00:00 8 1 9.9 4.6 8.8 0.6 10.3 6.5 180 4 188 305 1.6 0 2.2 1.5 10/21/2005 02:10:00 6.6 1.3 9.5 3 7.9 1.1 9.9 4.6 176 6 182 305 1.5 0.1 2.2 0.8 10/21/2005 02:20:00 8.2 1 9.5 4.2 8.6 0.9 9.9 5.3 184 4 184 305 1.2 0.3 1.5 0.6 10/21/2005 02:30:00 8.8 0.4 9.9 7.6 9 0.5 10.3 8 189 3 192 305 1.4 0 2 1.3 10/21/2005 02:40:00 8.2 0.4 9.1 6.5 8.5 0.4 9.5 7.6 187 3 190 305 1.4 0 2 1.3 10/21/2005 02:50:00 8.7 0.5 9.9 7.2 9 0.5 10.3 7.2 188 3 188 305 1.2 0.1 1.7 1 10/21/2005 03:00:00 9 0.5 10.3 7.6 9.2 0.5 10.7 7.6 186 2 188 305 1 0 1.5 0.8 10/21/2005 03:10:00 9.5 0.6 11.5 7.6 9.8 0.6 11.1 7.6 185 3 189 305 1 0.1 1.5 0.8 10/21/2005 03:20:00 8.9 0.7 10.7 7.2 9.4 0.6 11.1 8 183 3 188 305 0.8 0.2 1.5 0.6 10/21/2005 03:30:00 7.3 0.5 8.4 6.1 7.6 0.6 9.1 6.1 185 2 186 305 0.5 0 1 0.3 10/21/2005 03:40:00 6.2 0.5 8.4 4.9 6.4 0.6 8.4 4.6 186 4 185 305 0.3 0 1 0.3 10/21/2005 03:50:00 7.7 0.5 8.8 5.7 7.9 0.5 8.8 6.1 188 3 191 305 1 0.2 1.5 0.6 10/21/2005 04:00:00 6.8 0.6 8.4 5.3 6.8 0.5 8.4 5.7 192 3 195 305 1.3 0 2 1.3 10/21/2005 04:10:00 6.9 0.5 8.4 5.7 6.9 0.5 8.4 4.9 192 3 190 305 1.2 0.1 1.7 1 10/21/2005 04:20:00 6.3 0.5 7.6 4.9 6.6 0.5 8 4.6 188 5 192 305 0.7 0.2 1.3 0.6 10/21/2005 04:30:00 5.8 1.3 7.6 2.3 6.3 1 8.4 3 182 7 188 305 0.6 0.1 1.3 0.3 10/21/2005 04:40:00 6.7 0.6 7.6 4.2 7 0.4 8 4.9 185 6 186 305 1 0.2 1.7 0.6 10/21/2005 04:50:00 6.1 0.8 9.1 3.8 6.1 0.7 8.4 4.2 149 6 153 305 0.3 0.3 1.5 0.1 10/21/2005 05:00:00 5.6 1 7.6 3 6.1 1 8.8 3.4 173 15 192 305 0.4 0.3 1.3 0.1 10/21/2005 05:10:00 5 0.8 6.8 2.3 5.3 0.6 7.2 3.8 187 9 186 305 0.7 0.1 1 0.3 10/21/2005 05:20:00 3 0.7 4.6 1.5 4.4 0.4 5.3 3.4 173 7 186 305 0.3 0.1 0.8 0.1 10/21/2005 05:30:00 3.1 0.6 4.6 1.9 4 0.3 5.3 3.4 159 5 159 305 -0.2 0.1 0.3 -0.4 10/21/2005 05:40:00 4.6 0.3 5.3 3.8 4.7 0.3 5.3 4.2 143 3 144 305 -0.3 0 0.1 -0.4 10/21/2005 05:50:00 5 0.5 6.1 2.6 5.3 0.3 6.1 4.6 149 7 153 305 -0.1 0 0.1 -0.4 10/21/2005 06:00:00 5.3 0.7 6.8 3 5.7 0.3 6.5 4.9 155 5 156 305 -0.4 0.1 0.1 -0.6 10/21/2005 06:10:00 5.8 0.5 6.8 3.8 5.9 0.3 6.8 4.9 151 5 149 305 -0.5 0 -0.4 -0.6 10/21/2005 06:20:00 6.3 0.4 7.2 4.9 6 0.3 6.8 5.3 151 4 153 305 -0.6 0 -0.6 -0.8 10/21/2005 06:30:00 6.8 0.6 8 4.6 6.5 0.4 7.6 5.7 154 4 152 305 -0.7 0 0.1 -0.8 10/21/2005 06:40:00 6.3 0.9 8.4 3.8 6.7 0.4 7.6 5.7 157 4 155 305 -0.4 0.1 0.1 -0.8 10/21/2005 06:50:00 4.3 1.1 7.2 2.6 5.9 0.4 6.8 4.9 161 4 155 305 -0.2 0.2 0.1 -0.6 10/21/2005 07:00:00 5.9 0.8 7.2 3 6.4 0.4 7.6 5.3 154 5 145 305 -0.7 0 -0.4 -1.1 10/21/2005 07:10:00 5.7 0.4 6.8 4.2 5.7 0.3 6.5 4.9 151 6 156 305 -1.1 0 -0.6 -1.3 10/21/2005 07:20:00 5.9 0.6 7.6 4.6 5.8 0.4 6.8 4.6 146 6 147 305 -0.2 0.1 0.3 -0.6 10/21/2005 07:30:00 6.7 0.5 8 4.9 6.4 0.4 7.2 5.3 153 4 154 305 -0.6 0.2 0.3 -1.1 10/21/2005 07:40:00 6.7 0.5 8 4.9 6.2 0.4 7.2 4.9 153 4 157 305 -0.8 0.1 -0.1 -1.1 10/21/2005 07:50:00 6.4 0.4 7.2 5.3 6.2 0.4 7.2 5.3 149 3 147 305 -0.8 0.1 -0.1 -1.1 10/21/2005 08:00:00 6 0.2 6.5 5.3 5.7 0.3 6.1 5.3 142 1 142 305 -0.8 0 -0.1 -1.1 10/21/2005 08:10:00 5.9 0.3 6.8 4.9 5.7 0.3 6.5 4.9 143 2 147 305 -0.8 0 -0.4 -1.1 10/21/2005 08:20:00 6.3 0.4 7.2 4.9 6.1 0.3 6.8 4.9 145 3 147 305 -0.2 0.1 0.6 -0.6 10/21/2005 08:30:00 6.1 0.4 7.2 4.9 5.9 0.4 6.8 4.6 142 3 147 305 0 0 0.6 -0.1 10/21/2005 08:40:00 5.3 0.6 6.5 3 5.1 0.6 6.1 3.4 148 5 154 305 0 0 0.6 -0.1 10/21/2005 08:50:00 5.1 0.4 5.7 3.4 5 0.5 5.7 3.4 143 5 148 305 -0.2 0.3 0.6 -1.1 10/21/2005 09:00:00 5.4 0.4 6.5 4.9 5.3 0.3 6.1 4.6 139 1 141 305 -1.2 0.2 -0.6 -1.3 10/21/2005 09:10:00 6.2 0.3 6.8 5.3 5.9 0.3 6.5 4.9 140 2 140 305 -1.1 0.1 -0.6 -1.3 10/21/2005 09:20:00 6.1 0.3 6.8 5.7 6.1 0.3 6.5 5.3 137 2 140 305 -1.3 0 -0.6 -1.3 10/21/2005 09:30:00 5.2 0.3 6.1 4.6 5.3 0.3 6.1 4.6 137 2 134 305 -1.1 0 -0.6 -1.1 10/21/2005 09:40:00 4.9 0.4 5.7 3.8 4.9 0.3 5.7 4.2 130 8 135 305 -0.8 0.4 0.1 -1.3 10/21/2005 09:50:00 4.1 0.6 5.7 1.9 4.1 0.6 5.7 2.6 118 10 114 305 0.4 0 0.6 0.1 10/21/2005 10:00:00 4.6 0.7 5.7 2.3 4.6 0.6 5.7 2.6 136 5 134 305 0.3 0.2 0.6 -0.4 10/21/2005 10:10:00 5.6 0.3 6.1 4.9 5.4 0.3 6.1 4.6 138 1 138 305 -0.5 0 -0.4 -0.6 10/21/2005 10:20:00 5.2 0.6 6.5 3.8 5.3 0.5 6.5 3.4 130 6 130 305 -0.3 0.1 0.1 -0.6 10/21/2005 10:30:00 5.3 0.4 6.1 3.8 5.3 0.4 6.1 4.2 132 3 132 305 0 0 0.3 -0.1 10/21/2005 10:40:00 5.4 0.4 6.5 4.6 5.4 0.4 6.5 4.6 134 2 134 305 0 0 0.1 -0.1 10/21/2005 10:50:00 5.3 0.4 6.5 4.2 5.2 0.4 6.5 4.6 130 5 121 305 0.1 0 0.3 0.1 10/21/2005 11:00:00 5.7 0.4 6.5 4.2 5.6 0.4 6.5 4.6 134 3 131 305 0.5 0 1 0.3 10/21/2005 11:10:00 5.5 0.3 6.1 4.6 5.5 0.3 6.1 4.6 135 2 137 305 0.6 0 0.8 0.6 10/21/2005 11:20:00 5.6 0.2 6.1 4.6 5.6 0.2 6.1 4.9 140 4 133 305 0.5 0.1 1 0.1 10/21/2005 11:30:00 5.2 0.5 6.5 3.8 5.2 0.4 6.1 3.8 145 3 150 305 0.1 0 0.3 0.1 10/21/2005 11:40:00 5.1 0.3 5.7 4.2 5.1 0.3 6.1 4.2 139 3 145 305 0 0 0.3 -0.1 10/21/2005 11:50:00 4.6 0.2 4.9 4.2 4.6 0.2 4.9 3.8 143 2 141 305 0.4 0 0.8 0.3 10/21/2005 12:00:00 4.4 0.4 4.9 3 4.6 0.3 5.3 3.8 142 2 143 305 0.5 0 1 0.3 10/21/2005 12:10:00 3.4 0.4 4.2 2.6 3.9 0.3 4.6 3.4 139 2 139 305 0.5 0 1 0.6 10/21/2005 12:20:00 3.6 0.2 3.8 3 3.9 0.2 4.2 3.4 134 3 136 305 0.9 0.2 1.5 0.6 10/21/2005 12:30:00 2.4 1 4.2 0.4 2.7 0.9 4.2 0.7 136 11 137 305 1.4 0.1 2 1.3 10/21/2005 12:40:00 2.5 0.6 3.8 1.1 3 0.4 4.2 1.9 148 5 150 305 1.9 0 2.5 1.5 10/21/2005 12:50:00 2 0.5 3.4 0.4 2.8 0.5 3.8 1.5 154 8 153 305 2.3 0.2 2.9 2 10/21/2005 13:00:00 3.5 0.7 4.2 1.1 3.8 0.5 4.6 2.3 147 7 149 305 1.6 0.2 2.5 1.3 10/21/2005 13:10:00 3 0.5 3.8 1.1 3.4 0.4 4.2 2.3 147 7 147 305 1.2 0.1 1.5 1 10/21/2005 13:20:00 1.8 0.7 3.4 0.4 2.7 0.6 3.8 1.1 158 10 159 305 1.3 0.3 2.5 1 10/21/2005 13:30:00 0.8 0.4 1.9 0.4 1.7 0.4 2.6 0.7 165 12 148 305 2.5 0.3 3.4 2 10/21/2005 13:40:00 1 0.7 3 0.4 1.4 0.8 3 0.4 199 19 179 305 2.2 0.4 3.2 1.5 10/21/2005 13:50:00 2.2 1 3.8 0.4 2.8 0.7 4.2 1.5 187 10 192 305 1.3 0.2 2.2 0.8 10/21/2005 14:00:00 2.1 0.9 3.4 0.4 2.5 0.8 3.8 0.4 197 8 193 305 0.9 0.1 1.3 0.6 10/21/2005 14:10:00 2 0.7 3 0.4 2.4 0.5 3.4 1.5 183 7 193 305 0.9 0.1 1.5 0.6 10/21/2005 14:20:00 0.5 0.4 1.9 0.4 0.9 0.5 2.3 0.4 198 17 186 305 1.6 0.2 2.2 1.3 10/21/2005 14:30:00 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 203 12 305 305 2 0.1 2.7 2 10/21/2005 14:40:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 192 0 305 305 2.1 0.1 2.5 2 10/21/2005 14:50:00 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 183 8 305 305 2.4 0.4 3.4 2 10/21/2005 15:00:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 174 0 305 305 4 0.5 4.9 2.9 10/21/2005 15:10:00 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 85 66 13 305 3.9 0.6 4.9 2.7 10/21/2005 15:20:00 1.8 0.5 2.6 0.4 2.2 0.4 3 0.7 28 7 31 305 2.1 0.3 2.9 1.5 10/21/2005 15:30:00 0.6 0.4 1.9 0.4 1.4 0.4 2.3 0.7 32 5 26 305 1.7 0.1 2.2 1.5 10/21/2005 15:40:00 0.4 0.1 1.1 0.4 1 0.4 1.9 0.4 57 6 48 305 1.9 0.2 2.5 1.5 10/21/2005 15:50:00 0.4 0.2 1.1 0.4 0.9 0.4 1.9 0.4 157 76 213 305 2.8 0.2 3.4 2.2 10/21/2005 16:00:00 1.5 0.7 2.6 0.4 2.1 0.6 3 0.4 144 22 131 305 2.7 0.1 3.2 2.5 10/21/2005 16:10:00 2.1 0.6 3.8 0.4 2.4 0.6 3.8 0.7 143 8 147 305 3 0.2 3.7 2.7 10/21/2005 16:20:00 1.9 0.6 3 0.4 2.5 0.4 3.4 1.1 143 11 141 305 2.3 0.4 3.4 1.5 10/21/2005 16:30:00 2.4 0.5 3.4 0.7 2.8 0.4 3.4 1.9 143 7 139 305 1.5 0.2 2.2 1 10/21/2005 16:40:00 1.6 0.8 2.6 0.4 2.3 0.6 3 0.4 154 16 140 305 1 0.2 1.5 0.8 10/21/2005 16:50:00 1.8 0.7 3 0.4 2.1 0.5 3.4 0.7 199 15 198 305 0.8 0.2 1.3 0.6 10/21/2005 17:00:00 3.7 0.5 4.6 3 3.8 0.4 4.6 3 195 4 198 305 0.6 0.1 1.3 0.6 10/21/2005 17:10:00 3.3 0.3 4.2 2.6 3.4 0.3 4.2 2.3 191 4 191 305 0.5 0 1 0.3 10/21/2005 17:20:00 3.8 0.4 4.9 3 4 0.4 4.9 3 188 4 192 305 0.5 0 1 0.3 10/21/2005 17:30:00 3.5 0.3 4.6 2.6 3.7 0.3 4.6 2.6 191 6 193 305 0.3 0 0.8 0.3 10/21/2005 17:40:00 3 0.4 3.8 2.3 3 0.4 3.8 2.3 197 7 189 305 0.6 0.1 1.3 0.3 10/21/2005 17:50:00 2.3 0.4 4.2 1.1 2.4 0.4 3.8 1.5 197 12 211 305 0.7 0.1 1.3 0.6 10/21/2005 18:00:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.3 215 6 221 305 0.9 0.1 1.5 0.6 10/21/2005 18:10:00 3.3 0.3 4.2 2.3 3.3 0.4 4.2 2.3 215 5 218 305 0.7 0.1 1.3 0.6 10/21/2005 18:20:00 3.5 0.3 4.2 2.3 3.6 0.4 4.6 2.3 208 6 205 305 0.6 0 1 0.3 10/21/2005 18:30:00 3 0.4 3.8 1.9 3.2 0.4 3.8 1.9 215 6 212 305 0.5 0 1 0.3 10/21/2005 18:40:00 2.8 0.3 3.4 1.9 2.8 0.3 3.4 1.9 219 3 225 305 0.6 0.1 1 0.3 10/21/2005 18:50:00 2.8 0.3 3.4 1.9 2.9 0.3 3.4 1.9 213 5 218 305 0.5 0 1 0.6 10/21/2005 19:00:00 2.1 0.5 3 1.1 2.3 0.3 3 1.5 219 6 230 305 0.5 0 1 0.6 10/21/2005 19:10:00 1.6 0.4 2.6 0.7 1.8 0.3 2.6 1.1 219 7 231 305 0.5 0 1 0.6 10/21/2005 19:20:00 1.8 0.3 2.6 0.7 2 0.3 2.6 1.1 219 8 217 305 0.6 0 1 0.6 10/21/2005 19:30:00 1.6 0.3 2.3 0.7 1.8 0.2 2.3 1.1 234 7 239 305 0.6 0 1 0.6 10/21/2005 19:40:00 1.1 0.5 2.3 0.4 1.6 0.3 2.3 1.1 234 6 242 305 0.4 0 0.8 0.3 10/21/2005 19:50:00 1 0.2 1.5 0.4 1.5 0.2 1.9 1.1 236 3 234 305 0.4 0 0.8 0.3 10/21/2005 20:00:00 0.9 0.3 1.5 0.4 1.5 0.2 2.3 0.7 220 17 235 305 0.2 0.1 0.3 0.1 10/21/2005 20:10:00 0.8 0.3 1.5 0.4 1.5 0.2 2.3 1.1 193 5 200 305 0.1 0 0.6 0.1 10/21/2005 20:20:00 1.2 0.5 2.3 0.4 1.7 0.4 2.6 0.7 190 9 195 305 0.1 0 0.3 0.1 10/21/2005 20:30:00 1.6 0.3 2.3 0.7 2 0.3 2.6 1.5 200 9 193 305 0.4 0 0.6 0.1 10/21/2005 20:40:00 1.5 0.4 2.3 0.4 1.7 0.4 2.6 0.7 218 13 206 305 0.5 0 1 0.3 10/21/2005 20:50:00 0.6 0.3 1.5 0.4 1.1 0.3 1.9 0.4 217 19 238 305 0.4 0 1 0.3 10/21/2005 21:00:00 1.6 0.4 2.3 0.7 1.5 0.4 2.3 0.4 249 12 249 305 0.3 0 0.8 0.1 10/21/2005 21:10:00 2.3 0.4 3 1.5 2.3 0.4 3 1.1 279 5 283 305 0.5 0 1 0.3 10/21/2005 21:20:00 2.4 0.3 3 1.9 2.7 0.3 3.4 1.9 294 3 287 305 0.5 0 1 0.3 10/21/2005 21:30:00 2.4 0.3 3 1.9 2.6 0.2 3 2.3 296 4 297 305 0.3 0.1 0.8 0.1 10/21/2005 21:40:00 2.3 0.3 3 1.5 2.4 0.4 3 1.5 277 6 284 305 0.2 0.1 0.6 0.1 10/21/2005 21:50:00 2.5 0.3 3.4 1.9 2.2 0.4 3.4 1.5 260 4 259 305 0.3 0 0.6 0.1 10/21/2005 22:00:00 1.7 0.5 2.6 0.7 1.7 0.5 2.6 0.7 257 1 256 305 0.3 0 0.8 0.1 10/21/2005 22:10:00 0.8 0.3 1.5 0.4 1.1 0.3 1.9 0.4 257 4 256 305 0.3 0 0.8 0.1 10/21/2005 22:20:00 0.5 0.2 1.1 0.4 0.7 0.2 1.5 0.4 262 0 262 305 0.1 0.1 0.6 0.1 10/21/2005 22:30:00 1 0.7 2.6 0.4 1.7 0.7 3 0.4 197 29 186 305 0 0 0.6 -0.1 10/21/2005 22:40:00 1.4 0.2 1.9 0.7 2.1 0.2 2.6 1.5 189 3 187 305 -0.1 0 0.3 -0.1 10/21/2005 22:50:00 1.6 0.3 2.3 0.7 2.3 0.2 2.6 1.5 184 4 181 305 -0.1 0 0.3 -0.4 10/21/2005 23:00:00 0.5 0.3 1.5 0.4 1.5 0.3 2.3 1.1 192 5 187 305 -0.1 0 0.3 -0.4 10/21/2005 23:10:00 0.4 0.2 1.5 0.4 1.1 0.4 1.9 0.4 197 0 197 305 -0.2 0.1 0.3 -0.4 10/21/2005 23:20:00 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 197 0 305 305 -0.1 0.1 0.1 -0.4 10/21/2005 23:30:00 1.2 0.5 2.3 0.4 1.6 0.4 2.6 0.7 213 10 227 305 0 0 0.3 0.1 10/21/2005 23:40:00 1.9 0.3 2.6 1.1 2.3 0.3 2.6 1.5 199 5 205 305 0.2 0 0.3 0.1 10/21/2005 23:50:00 1.9 0.3 2.6 1.1 2.2 0.3 2.6 1.5 202 5 210 305 0.2 0 0.3 0.1 10/22/2005 00:00:00 1.5 0.4 2.3 0.7 2 0.3 2.6 1.1 197 6 198 305 0.1 0.1 0.6 -0.1 10/22/2005 00:10:00 0.8 0.3 1.5 0.4 1.5 0.3 2.3 1.1 204 5 200 305 -0.3 0 0.1 -0.4 10/22/2005 00:20:00 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 218 9 305 305 -0.4 0 0.3 -0.4 10/22/2005 00:30:00 1.2 0.5 2.3 0.4 1.6 0.3 2.6 1.1 220 7 216 305 -0.5 0 0.1 -0.6 10/22/2005 00:40:00 1.2 0.5 2.6 0.4 1.5 0.4 2.6 0.4 206 15 206 305 0 0.2 0.6 -0.4 10/22/2005 00:50:00 0.4 0.2 1.5 0.4 0.7 0.5 2.3 0.4 232 8 235 305 -0.1 0 0.6 -0.4 10/22/2005 01:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 232 5 305 305 -0.1 0 0.3 -0.4 10/22/2005 01:10:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 220 0 305 305 -0.4 0.2 0.3 -0.6 10/22/2005 01:20:00 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 217 5 305 305 -0.7 0 0.1 -1.1 10/22/2005 01:30:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 211 0 305 305 -0.8 0 -0.4 -1.1 10/22/2005 01:40:00 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 211 0 305 305 -0.6 0.1 0.1 -0.8 10/22/2005 01:50:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 211 0 305 305 -0.4 0.1 1 -0.6 10/22/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 211 0 305 305 -0.3 0.1 0.3 -0.6 10/22/2005 02:10:00 0.4 0.3 1.9 0.4 0.9 0.3 1.5 0.4 356 43 344 305 -0.2 0.2 0.6 -0.6 10/22/2005 02:20:00 0.9 0.6 2.6 0.4 1.1 0.5 2.6 0.4 353 32 348 305 0 0 0.6 -0.1 10/22/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 36 0 305 305 -0.1 0 0.3 -0.4 10/22/2005 02:40:00 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 79 45 305 305 -0.3 0.1 0.1 -0.4 10/22/2005 02:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 84 61 305 305 -0.4 0 0.3 -0.6 10/22/2005 03:00:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 5 0 305 305 -0.3 0 0.3 -0.4 10/22/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 0 305 305 -0.3 0.2 0.3 -0.6 10/22/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 0 305 305 -0.7 0 0.1 -1.1 10/22/2005 03:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 5 0 305 305 -1.1 0 -0.4 -1.3 10/22/2005 03:40:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 285 64 248 305 -0.7 0 0.1 -1.1 10/22/2005 03:50:00 0.4 0.2 1.9 0.4 0.4 0.2 1.1 0.4 280 51 287 305 -0.4 0.3 0.1 -0.8 10/22/2005 04:00:00 0.9 1 4.9 0.4 0.9 0.8 5.3 0.4 297 32 339 305 0 0 0.6 -0.1 10/22/2005 04:10:00 5.6 0.7 6.8 3.8 6 0.8 7.6 3.4 342 6 338 305 0.8 0.3 1 0.1 10/22/2005 04:20:00 6.3 0.4 7.2 4.9 6.8 0.4 7.6 5.3 347 8 337 305 1 0 1.3 0.8 10/22/2005 04:30:00 5 1.2 6.8 2.6 5.6 1.2 7.6 2.6 347 11 358 305 0.5 0.1 1 0.1 10/22/2005 04:40:00 0.8 0.7 2.6 0.4 1.3 0.7 3 0.4 329 9 330 305 0.2 0 0.3 0.1 10/22/2005 04:50:00 0.7 0.3 1.5 0.4 1.3 0.3 1.9 0.4 17 11 1 305 0.1 0 0.6 0.1 10/22/2005 05:00:00 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 25 20 339 305 -0.4 0.2 0.6 -0.6 10/22/2005 05:10:00 2.2 0.5 3 0.4 2.2 0.8 3.4 0.4 349 6 350 305 -0.4 0.2 0.3 -0.6 10/22/2005 05:20:00 3.2 0.8 5.3 1.9 3.5 0.7 5.7 2.3 359 6 13 305 0.6 0.2 1 0.3 10/22/2005 05:30:00 4.9 0.4 6.1 3.8 5.2 0.3 6.1 4.6 20 5 24 305 1 0 1.3 0.8 10/22/2005 05:40:00 5.4 0.7 6.8 3.8 5.8 0.7 7.2 4.2 14 3 14 305 1.1 0 1.3 1 10/22/2005 05:50:00 5.9 0.4 7.2 4.6 6.3 0.5 7.6 4.9 21 4 27 305 1.1 0 1.3 1 10/22/2005 06:00:00 5.9 0.5 6.8 4.9 6.4 0.4 7.6 5.3 18 3 17 305 1.2 0 1.5 1 10/22/2005 06:10:00 6 0.4 6.8 4.9 6.4 0.4 7.2 5.3 21 3 20 305 1.3 0.1 2 1.3 10/22/2005 06:20:00 5.6 0.3 6.5 4.6 6 0.4 6.8 4.9 21 4 18 305 1.3 0.1 2 1 10/22/2005 06:30:00 6.5 0.4 7.2 5.3 6.9 0.4 7.6 5.7 18 5 12 305 1.4 0 2 1.3 10/22/2005 06:40:00 6.4 0.3 7.2 5.7 6.8 0.4 7.6 5.7 24 3 20 305 1.4 0 2 1.3 10/22/2005 06:50:00 6.5 0.3 7.2 5.7 6.9 0.4 8 6.1 23 3 21 305 1.4 0 2 1.3 10/22/2005 07:00:00 6.6 0.4 7.6 5.3 7 0.5 8 5.7 21 4 17 305 1.5 0 2 1.3 10/22/2005 07:10:00 7.1 0.8 9.1 5.3 7.5 0.8 9.9 5.7 16 3 13 305 1.6 0 2.2 1.5 10/22/2005 07:20:00 8.3 0.4 9.5 7.2 8.7 0.4 9.5 7.2 12 3 12 305 1.4 0 2 1.3 10/22/2005 07:30:00 8.3 0.6 9.9 6.5 8.7 0.6 9.9 6.5 10 4 10 305 1.4 0 2 1.3 10/22/2005 07:40:00 8.6 0.6 9.9 6.1 9 0.7 10.3 6.5 7 2 7 305 1.2 0.1 1.7 1 10/22/2005 07:50:00 7.7 0.4 8.8 6.5 8.1 0.4 9.1 6.8 2 3 0 305 1 0 1.5 1 10/22/2005 08:00:00 7.1 0.5 8.4 5.7 7.5 0.5 8.8 6.1 357 4 359 305 1 0 1.5 1 10/22/2005 08:10:00 7.6 0.4 8.4 6.1 8.1 0.4 9.1 6.8 348 2 348 305 1 0 1.5 0.8 10/22/2005 08:20:00 7.6 0.4 8.4 6.5 8 0.4 8.8 6.8 343 3 343 305 0.8 0 1.3 0.6 10/22/2005 08:30:00 7.1 0.4 8 6.1 7.6 0.4 8.4 6.8 341 3 344 305 0.7 0 1 0.6 10/22/2005 08:40:00 6.2 0.5 7.2 4.9 6.7 0.5 8 5.3 342 3 346 305 0.6 0 1 0.6 10/22/2005 08:50:00 4.8 0.3 5.7 3.8 5.3 0.4 6.1 4.6 345 4 347 305 0.6 0 1 0.6 10/22/2005 09:00:00 4.6 0.3 5.7 3.8 4.9 0.3 6.1 4.2 340 3 339 305 0.6 0 1 0.6 10/22/2005 09:10:00 4.4 0.3 4.9 3.4 4.6 0.3 5.3 3.8 334 5 336 305 0.6 0 0.8 0.6 10/22/2005 09:20:00 4 0.3 4.9 3.4 4.3 0.3 4.9 3.8 325 5 329 305 0.5 0 0.6 0.6 10/22/2005 09:30:00 3.6 0.2 4.2 3 3.8 0.2 4.6 3.4 325 3 320 305 0.5 0 0.8 0.6 10/22/2005 09:40:00 3 0.5 3.8 1.9 3.3 0.5 4.2 1.9 331 8 321 305 0.5 0 1 0.6 10/22/2005 09:50:00 1.8 0.3 2.6 1.1 2.2 0.3 3 1.5 345 6 336 305 0.5 0 0.8 0.6 10/22/2005 10:00:00 1.7 0.3 2.3 1.1 2.2 0.3 3 1.5 351 5 348 305 0.6 0.1 1.3 0.6 10/22/2005 10:10:00 2.1 0.3 3 1.1 2.4 0.3 3.4 1.5 6 9 3 305 0.7 0 1.3 0.6 10/22/2005 10:20:00 2.2 0.4 3.4 1.5 2.6 0.4 3.4 1.9 17 7 27 305 0.7 0 1.3 0.6 10/22/2005 10:30:00 2.8 0.5 3.8 1.5 3 0.4 4.2 2.3 24 5 21 305 0.7 0 1 0.6 10/22/2005 10:40:00 3.1 0.3 3.8 2.3 3.4 0.3 3.8 2.6 20 5 27 305 0.8 0 1.3 0.6 10/22/2005 10:50:00 3.2 0.3 4.2 2.6 3.4 0.3 4.2 2.6 19 4 16 305 0.9 0 1.5 0.8 10/22/2005 11:00:00 3.4 0.3 4.2 2.6 3.7 0.3 4.6 3 18 5 19 305 1 0.1 1.5 0.8 10/22/2005 11:10:00 4.3 0.4 5.3 3.4 4.5 0.4 5.3 3.4 16 4 17 305 1.1 0 1.5 1 10/22/2005 11:20:00 4.9 0.6 6.5 3.4 5.2 0.6 6.5 3.8 29 13 46 305 1.1 0.1 1.5 0.6 10/22/2005 11:30:00 5.4 0.4 6.5 3.8 5.5 0.5 6.5 3.8 52 4 58 305 0.4 0.1 1 0.1 10/22/2005 11:40:00 3.5 0.4 4.6 2.6 3.6 0.4 4.6 2.6 45 5 53 305 0.2 0 0.6 0.1 10/22/2005 11:50:00 2.5 0.4 3.4 1.5 2.7 0.3 3.4 1.9 55 9 46 305 0.3 0 0.8 0.3 10/22/2005 12:00:00 1.7 0.4 2.6 0.7 2 0.4 3 1.1 61 7 68 305 0.4 0 1 0.3 10/22/2005 12:10:00 3.4 1.3 5.3 1.1 3.5 1.2 5.7 1.5 35 11 30 305 0.7 0.2 1.3 0.3 10/22/2005 12:20:00 5.6 0.4 6.5 4.2 5.8 0.4 6.8 4.6 29 7 20 305 1.1 0.1 1.5 1 10/22/2005 12:30:00 5.4 0.7 6.8 3.8 5.5 0.7 6.8 4.2 51 6 43 305 1 0.2 1.5 0.6 10/22/2005 12:40:00 4.6 0.4 5.7 3.8 4.7 0.5 6.1 3.8 50 6 46 305 0.6 0.1 1.3 0.6 10/22/2005 12:50:00 3.9 0.4 4.6 3 4.2 0.4 4.9 3.4 39 4 38 305 0.8 0 1.3 0.6 10/22/2005 13:00:00 3.3 0.3 4.2 2.6 3.6 0.2 4.2 3 33 4 25 305 0.9 0 1.3 0.8 10/22/2005 13:10:00 4.3 0.6 6.1 3 4.5 0.6 6.1 3.4 28 5 25 305 1 0 1.5 0.8 10/22/2005 13:20:00 4.2 0.5 5.3 3 4.4 0.5 5.7 3.4 18 5 20 305 0.7 0 1 0.6 10/22/2005 13:30:00 4.9 0.4 5.7 3.8 5.2 0.5 6.1 3.8 2 7 1 305 0.9 0 1 0.8 10/22/2005 13:40:00 5.1 0.4 6.1 4.2 5.5 0.4 6.1 4.6 2 4 2 305 1 0 1.5 1 10/22/2005 13:50:00 5.5 0.4 6.5 4.6 5.9 0.4 6.8 4.9 353 5 352 305 0.7 0.2 1 0.6 10/22/2005 14:00:00 5.2 0.3 6.1 4.2 5.7 0.4 6.8 4.6 347 4 348 305 0.5 0 1 0.3 10/22/2005 14:10:00 4.7 0.3 5.3 3.8 5.1 0.4 6.1 3.8 354 3 357 305 0.5 0 0.6 0.3 10/22/2005 14:20:00 4.5 0.3 5.3 3.4 4.9 0.4 6.1 3.8 356 4 352 305 0.5 0 1 0.6 10/22/2005 14:30:00 4.8 0.4 5.7 3.8 5.2 0.3 6.1 4.2 5 3 4 305 0.5 0 0.6 0.3 10/22/2005 14:40:00 4.6 0.3 5.3 3.8 5 0.3 5.7 3.8 3 3 6 305 0.4 0 0.6 0.3 10/22/2005 14:50:00 4.6 0.3 5.3 3.8 5 0.4 6.1 4.2 355 4 355 305 0.4 0 0.6 0.3 10/22/2005 15:00:00 5.5 0.5 6.5 3.8 5.9 0.5 6.8 4.2 347 4 344 305 0.3 0.1 0.6 0.1 10/22/2005 15:10:00 6 0.4 6.5 4.9 6.4 0.4 7.2 5.3 343 2 343 305 0.1 0.1 0.6 0.1 10/22/2005 15:20:00 5.6 0.5 6.5 4.6 5.9 0.4 6.8 4.6 338 7 331 305 0.1 0.1 0.6 0.1 10/22/2005 15:30:00 5.8 0.5 6.8 4.2 6.1 0.5 7.2 4.6 319 7 328 305 0 0 0.6 -0.1 10/22/2005 15:40:00 5.4 1.2 8 3.4 5.8 1.2 8.4 3.8 332 9 345 305 0 0.1 0.6 0.1 10/22/2005 15:50:00 6.7 1.5 11.1 4.2 7.1 1.5 12.2 4.6 351 6 355 305 0 0 0.6 -0.1 10/22/2005 16:00:00 14.6 2.8 19.5 8 14.7 2.8 20.2 8 347 5 350 305 0 0 0.6 -0.1 10/22/2005 16:10:00 16.7 1.5 20.6 12.6 16.7 1.6 21 12.6 348 4 346 305 0 0 0.6 -0.1 10/22/2005 16:20:00 18.1 1.8 22.1 14.1 18.1 1.8 22.9 13.7 349 4 347 305 0 0 0.6 -0.1 10/22/2005 16:30:00 18.2 1.7 22.1 13.7 18.2 1.7 22.6 13.3 350 4 347 305 -0.1 0 0.6 -0.4 10/22/2005 16:40:00 17.3 1.4 20.2 13 17.4 1.3 21 13.3 351 4 354 305 0 0 0.6 -0.1 10/22/2005 16:50:00 15.5 1.8 19.9 11.8 15.7 1.8 19.9 11.5 358 6 352 305 -0.1 0 0.6 -0.4 10/22/2005 17:00:00 16.2 2.2 21 12.2 16.4 2.1 21.8 11.8 350 7 340 305 -0.1 0 0.1 -0.4 10/22/2005 17:10:00 18.3 2 24.4 13.7 18.5 2 24.4 13.3 345 5 344 305 -0.1 0 0.6 -0.4 10/22/2005 17:20:00 16.8 2.4 21.8 11.5 17.2 2.4 22.9 11.5 343 4 343 305 0 0 0.6 0.1 10/22/2005 17:30:00 9.9 2.4 15.6 6.5 10.3 2.4 16.4 6.8 357 6 346 305 0.5 0.2 1 0.3 10/22/2005 17:40:00 6.9 1.2 9.9 4.2 6.9 1.2 9.5 4.2 63 24 99 305 0.5 0.1 1 0.1 10/22/2005 17:50:00 9.4 1.2 12.2 6.1 8.9 1.2 11.5 6.1 92 11 100 305 0 0 0.6 -0.1 10/22/2005 18:00:00 8.4 1 11.1 5.7 7.8 0.9 9.9 5.7 77 6 81 305 0 0 0.6 -0.1 10/22/2005 18:10:00 7.8 0.5 8.8 6.1 7.7 0.7 9.1 5.3 49 21 84 305 0 0 0.3 0.1 10/22/2005 18:20:00 8.4 1 11.1 6.5 8.8 1 11.5 6.8 355 11 354 305 0.1 0.1 0.3 0.1 10/22/2005 18:30:00 9 1.7 14.9 5.3 9.2 1.7 14.9 5.7 2 3 358 305 -0.1 0 0.1 -0.4 10/22/2005 18:40:00 13.3 1.5 16.8 9.9 13.4 1.4 17.6 9.9 359 5 5 305 -0.3 0 0.1 -0.4 10/22/2005 18:50:00 15.6 1.9 19.9 11.1 15.8 2 19.9 11.5 351 5 343 305 -0.3 0 -0.1 -0.4 10/22/2005 19:00:00 16.5 1.5 20.6 13 16.6 1.6 20.6 12.2 345 5 352 305 -0.4 0 0.1 -0.4 10/22/2005 19:10:00 18.4 1.8 22.9 13.7 18.5 1.9 23.3 13.7 345 5 337 305 -0.3 0 0.1 -0.4 10/22/2005 19:20:00 20.3 1.9 24.8 14.5 20.4 2.1 26.3 13.3 346 4 347 305 -0.3 0 0.1 -0.4 10/22/2005 19:30:00 20.2 1.7 24 14.9 20.3 1.7 24.4 15.6 347 5 350 305 -0.3 0 -0.1 -0.4 10/22/2005 19:40:00 19.9 1.5 22.9 14.5 19.8 1.6 23.7 14.1 349 4 344 305 -0.3 0 -0.1 -0.4 10/22/2005 19:50:00 18.6 1.7 22.1 14.1 18.7 1.8 22.9 14.5 350 4 347 305 -0.2 0 0.3 -0.4 10/22/2005 20:00:00 18.5 1.6 22.9 13 18.5 1.7 22.6 14.5 346 5 339 305 -0.2 0 0.6 -0.4 10/22/2005 20:10:00 19.9 1.9 23.7 13.3 19.9 2 24.4 13.3 346 4 346 305 0 0 0.6 -0.1 10/22/2005 20:20:00 19.6 1.7 23.7 14.9 19.6 1.9 23.7 13.7 346 5 344 305 0 0.1 0.6 -0.1 10/22/2005 20:30:00 9.9 2.8 21.4 6.5 10.1 2.8 21.8 6.5 4 11 353 305 0.5 0.1 1 0.1 10/22/2005 20:40:00 8.2 0.8 9.9 5.7 8.5 0.8 10.7 6.1 9 6 2 305 0.5 0.1 1.3 0.3 10/22/2005 20:50:00 9.5 0.9 11.8 7.2 9.9 0.9 11.8 7.6 358 3 349 305 0.6 0.1 1.3 0.6 10/22/2005 21:00:00 11.6 2.2 16.4 6.8 11.8 2.2 16.8 7.2 349 8 340 305 0.2 0.3 1 -0.4 10/22/2005 21:10:00 15.6 2.4 20.2 10.3 15.7 2.5 20.2 9.1 2 4 1 305 -0.1 0 0.6 -0.4 10/22/2005 21:20:00 16.4 1.7 21 12.2 16.4 1.7 21 12.6 358 5 353 305 -0.2 0.1 0.3 -0.4 10/22/2005 21:30:00 18.5 2 22.9 13 18.6 2 22.9 13 351 3 348 305 -0.4 0.1 0.3 -0.6 10/22/2005 21:40:00 17.9 1.5 21.4 13.3 18 1.5 22.1 13.3 350 4 346 305 -0.4 0.2 0.3 -0.6 10/22/2005 21:50:00 17.4 1.7 21.8 13 17.5 1.7 21.8 13 350 4 348 305 -0.4 0.1 0.1 -0.6 10/22/2005 22:00:00 16.8 1.3 20.2 13 16.9 1.5 20.2 11.8 348 5 347 305 -0.4 0.1 0.3 -0.4 10/22/2005 22:10:00 15.9 1.8 20.2 10.7 16 1.8 21 10.7 343 5 347 305 -0.4 0 0.1 -0.6 10/22/2005 22:20:00 16.4 1.5 19.5 12.2 16.6 1.5 20.2 12.6 343 5 344 305 -0.4 0.1 0.1 -0.6 10/22/2005 22:30:00 17.3 2 21.8 13 17.3 2.1 22.1 12.2 344 5 338 305 -0.4 0 -0.1 -0.4 10/22/2005 22:40:00 18.5 1.9 23.3 13.7 18.7 1.9 23.7 14.5 345 5 349 305 -0.4 0 -0.1 -0.4 10/22/2005 22:50:00 18.6 2.1 23.7 14.1 18.7 2.2 23.3 13.7 344 4 340 305 -0.4 0 -0.4 -0.6 10/22/2005 23:00:00 18.2 1.6 21.8 12.6 18.3 1.6 21.8 13 347 5 352 305 -0.3 0 0.1 -0.4 10/22/2005 23:10:00 20 1.8 24.4 14.9 20 1.9 24 14.1 346 5 347 305 -0.3 0 0.3 -0.4 10/22/2005 23:20:00 20.9 2.2 24.8 14.9 20.9 2.2 25.6 15.3 345 5 350 305 -0.4 0 -0.1 -0.6 10/22/2005 23:30:00 20.8 1.9 25.6 14.9 20.9 2 25.6 15.6 348 5 347 305 -0.4 0 -0.1 -0.6 10/22/2005 23:40:00 21.5 1.9 26 17.2 21.5 1.9 26 16.4 349 4 347 305 -0.4 0 0.1 -0.6 10/22/2005 23:50:00 21.5 1.9 25.2 16.1 21.6 1.9 26.3 16.4 350 4 346 305 -0.3 0 0.1 -0.4 10/23/2005 00:00:00 20.5 2.3 24.8 14.9 20.5 2.3 24.8 15.3 352 4 349 305 -0.3 0 0.3 -0.4 10/23/2005 00:10:00 19 1.7 22.9 14.9 19 1.8 23.3 13.7 351 5 349 305 -0.3 0 0.1 -0.4 10/23/2005 00:20:00 17.9 2.1 22.6 12.2 17.9 2.1 22.9 11.8 350 5 351 305 -0.3 0 0.3 -0.4 10/23/2005 00:30:00 19.1 1.8 23.3 13.3 19.1 1.9 23.3 13 350 4 347 305 -0.3 0 0.3 -0.4 10/23/2005 00:40:00 18.2 2 22.6 13 18.4 2 22.9 13 348 4 347 305 -0.2 0 0.3 -0.4 10/23/2005 00:50:00 17.1 2.1 21.8 11.8 17.2 2.1 21.8 12.2 350 4 352 305 -0.1 0 0.6 -0.4 10/23/2005 01:00:00 16.8 1.8 20.6 12.6 16.8 1.9 21 12.6 351 5 353 305 0.2 0 0.6 0.1 10/23/2005 01:10:00 16.3 1.5 19.5 11.8 16.4 1.6 19.9 12.6 350 4 348 305 0.3 0 1 0.1 10/23/2005 01:20:00 14.3 1.4 17.2 9.9 14.5 1.5 17.6 9.9 352 5 352 305 0.4 0 1 0.3 10/23/2005 01:30:00 13.8 1.6 17.6 8.8 13.9 1.7 18.3 8.8 354 7 349 305 0.5 0 1 0.3 10/23/2005 01:40:00 13 1.1 15.6 10.3 13.2 1.1 16.1 10.3 353 6 355 305 0.5 0 1 0.3 10/23/2005 01:50:00 12.9 1.3 16.1 9.5 13.1 1.3 16.4 9.9 358 4 357 305 0.7 0.1 1.3 0.6 10/23/2005 02:00:00 16.3 1.5 19.9 12.6 16.4 1.5 20.6 12.6 354 4 355 305 0.4 0.2 1.3 0.1 10/23/2005 02:10:00 16.9 1.4 21 13 17.2 1.5 20.6 13.7 355 3 354 305 0 0 0.6 -0.1 10/23/2005 02:20:00 16.3 1.5 19.5 11.8 16.4 1.5 20.2 11.1 357 5 4 305 -0.2 0 0.3 -0.4 10/23/2005 02:30:00 17.9 1.6 21 13 18.1 1.7 21.4 13.7 354 4 354 305 -0.2 0 0.3 -0.4 10/23/2005 02:40:00 17.6 1.3 20.6 13.7 18 1.3 21 14.1 351 3 352 305 -0.3 0 0.3 -0.4 10/23/2005 02:50:00 16.3 1.2 18.7 12.2 16.4 1.3 19.5 13 350 4 351 305 -0.3 0 -0.1 -0.4 10/23/2005 03:00:00 16 1.2 18.7 13 16.2 1.2 19.5 11.8 349 5 349 305 -0.3 0 0.1 -0.6 10/23/2005 03:10:00 15.5 1 17.9 12.6 15.8 1.1 18.3 11.8 348 4 344 305 -0.1 0 0.1 -0.4 10/23/2005 03:20:00 13.7 1.2 16.1 10.7 13.9 1.2 16.4 11.1 350 4 349 305 0.3 0.1 0.6 0.1 10/23/2005 03:30:00 12.2 0.8 14.1 9.9 12.5 0.9 14.5 9.1 355 5 347 305 0.7 0 1 0.6 10/23/2005 03:40:00 11.2 0.7 13 8.8 11.4 0.8 13.3 8.8 12 5 8 305 1 0 1.3 0.8 10/23/2005 03:50:00 10.4 0.8 12.2 8.4 10.7 0.8 12.6 8.8 18 4 17 305 1 0 1 0.8 10/23/2005 04:00:00 9.6 1 11.5 7.2 9.7 1 12.2 6.8 22 3 22 305 1 0 1.5 0.8 10/23/2005 04:10:00 11.7 0.8 14.5 9.1 11.8 0.9 14.5 9.1 19 6 5 305 1 0 1.3 0.6 10/23/2005 04:20:00 15.6 1.7 19.1 11.1 15.8 1.8 19.5 11.5 4 9 358 305 0.3 0.2 0.8 0.1 10/23/2005 04:30:00 15.2 1.2 17.9 11.8 15.4 1.2 18.3 12.2 359 5 4 305 0.1 0 0.6 0.1 10/23/2005 04:40:00 16.1 1.3 18.7 12.2 16.3 1.3 19.1 12.2 356 4 352 305 0.1 0 0.3 0.1 10/23/2005 04:50:00 16 1.5 18.7 11.1 16.2 1.6 19.1 10.7 357 4 358 305 0.1 0.1 0.6 0.1 10/23/2005 05:00:00 15.3 1.3 19.1 12.2 15.6 1.4 19.5 12.6 354 4 355 305 0 0.1 0.6 0.1 10/23/2005 05:10:00 14 1.5 17.2 9.9 14.2 1.7 17.6 10.3 354 5 350 305 0 0.1 0.6 -0.1 10/23/2005 05:20:00 16 1.2 18.3 12.6 16.2 1.3 19.1 13 353 4 352 305 0.3 0 0.8 0.1 10/23/2005 05:30:00 15.7 1.5 18.7 10.7 15.8 1.6 19.1 10.7 355 4 351 305 0.4 0 1 0.3 10/23/2005 05:40:00 15.3 1.3 18.3 12.2 15.4 1.2 18.7 12.2 357 4 358 305 0.5 0 1 0.3 10/23/2005 05:50:00 16 1.5 19.1 13 16.1 1.5 19.5 12.6 4 5 2 305 0.6 0.1 1.3 0.3 10/23/2005 06:00:00 15.7 1.4 18.7 11.5 15.8 1.5 19.1 12.2 0 5 358 305 0.3 0.1 0.8 0.1 10/23/2005 06:10:00 16.8 1.1 19.1 13.7 16.9 1.1 19.1 13 358 3 1 305 0.1 0.1 0.6 0.1 10/23/2005 06:20:00 15.9 1.3 19.1 12.6 16 1.4 18.7 12.2 359 4 0 305 0.2 0.1 0.6 0.1 10/23/2005 06:30:00 15.6 1.7 18.7 10.7 15.7 1.8 19.1 10.3 359 4 356 305 0.2 0.1 0.6 0.1 10/23/2005 06:40:00 15.8 1.3 18.3 11.8 16.1 1.3 19.5 12.2 358 4 4 305 0.1 0.1 0.6 0.1 10/23/2005 06:50:00 15.3 1.4 18.3 11.5 15.5 1.5 18.7 11.8 357 4 354 305 0.2 0.1 0.6 0.1 10/23/2005 07:00:00 16.4 1 18.7 13 16.6 1.2 19.9 13 355 3 351 305 0.1 0.1 0.6 0.1 10/23/2005 07:10:00 16.3 1.2 18.7 12.6 16.5 1.3 19.1 12.2 355 3 0 305 0.1 0 0.6 0.1 10/23/2005 07:20:00 14.2 1.1 17.2 11.1 14.6 1.1 17.6 11.1 353 5 1 305 0.2 0 0.3 0.1 10/23/2005 07:30:00 14.8 1.7 18.3 9.1 15.1 1.7 18.7 10.3 353 4 357 305 0.2 0 0.6 0.1 10/23/2005 07:40:00 14.8 1.3 17.9 11.8 15 1.3 17.9 11.5 355 4 356 305 0.2 0 0.3 0.1 10/23/2005 07:50:00 15.1 1.3 17.9 11.8 15.3 1.4 18.3 12.2 353 4 351 305 0.1 0 0.6 0.1 10/23/2005 08:00:00 15.4 1.3 18.3 11.1 15.6 1.3 18.3 11.8 355 5 353 305 0 0 0.6 0.1 10/23/2005 08:10:00 15.8 1.3 18.7 12.2 16 1.3 19.1 12.6 358 5 1 305 0.1 0 0.3 0.1 10/23/2005 08:20:00 16.7 1.2 19.5 13 16.8 1.2 19.5 12.6 1 4 2 305 0.1 0 0.3 0.1 10/23/2005 08:30:00 17.2 1.3 20.2 13.7 17.4 1.3 20.2 13.7 357 3 2 305 0.1 0 0.6 0.1 10/23/2005 08:40:00 17 1.3 19.9 13 17 1.4 20.6 13.3 358 4 359 305 0.1 0 0.3 0.1 10/23/2005 08:50:00 17.3 1.3 19.9 13.7 17.5 1.4 20.2 13.7 356 4 3 305 0 0 0.1 0.1 10/23/2005 09:00:00 17.5 1.4 20.2 13.7 17.6 1.5 20.6 13.7 356 4 356 305 0 0 0.1 -0.1 10/23/2005 09:10:00 17.1 1.4 20.2 13 17.3 1.5 20.2 13 355 4 357 305 -0.1 0 0.1 -0.4 10/23/2005 09:20:00 16.6 1.5 19.9 12.2 16.9 1.6 20.6 12.6 354 4 354 305 -0.1 0 0.1 -0.4 10/23/2005 09:30:00 17 1.5 19.9 12.2 17.2 1.5 20.2 12.6 353 4 356 305 -0.1 0.1 0.6 -0.4 10/23/2005 09:40:00 16.8 1.5 19.9 12.2 17.1 1.5 20.6 13.3 356 4 355 305 -0.1 0 0.6 -0.4 10/23/2005 09:50:00 16.8 1.3 19.5 12.6 16.8 1.3 19.9 12.6 358 4 352 305 -0.1 0.1 0.6 -0.4 10/23/2005 10:00:00 16.5 1.2 19.1 13 16.7 1.3 19.5 12.6 353 4 350 305 -0.1 0 0.3 -0.4 10/23/2005 10:10:00 16.8 1.3 19.5 12.2 17.1 1.4 19.9 12.6 355 4 359 305 -0.1 0 0.6 -0.4 10/23/2005 10:20:00 15.9 1.3 18.3 12.6 16.1 1.4 19.5 12.6 357 4 357 305 0 0 0.6 -0.1 10/23/2005 10:30:00 16.2 1.1 18.7 12.6 16.5 1.2 19.1 13.3 354 4 357 305 -0.1 0 0.6 -0.4 10/23/2005 10:40:00 16.6 1 19.5 14.1 16.9 1.1 19.9 13 352 4 351 305 -0.1 0 0.3 -0.4 10/23/2005 10:50:00 15.8 1.1 17.9 12.2 16.1 1.3 18.3 11.8 351 4 347 305 -0.1 0 0.6 -0.4 10/23/2005 11:00:00 15.1 1.2 18.3 11.1 15.4 1.3 18.3 11.5 350 5 347 305 0 0 0.6 -0.4 10/23/2005 11:10:00 15.6 1.2 18.3 11.8 15.8 1.4 18.3 11.8 348 4 355 305 -0.1 0.1 0.6 -0.4 10/23/2005 11:20:00 16 1.2 18.3 12.2 16.2 1.3 18.7 12.6 350 4 350 305 0 0 0.6 -0.4 10/23/2005 11:30:00 15.3 1.3 17.9 12.2 15.5 1.4 18.7 11.8 351 4 350 305 0 0.1 0.6 -0.1 10/23/2005 11:40:00 15.6 1.2 17.6 12.2 15.7 1.3 18.3 12.2 353 4 355 305 0 0 0.6 -0.1 10/23/2005 11:50:00 15.3 1.2 17.9 12.2 15.7 1.3 18.3 11.8 351 4 351 305 0 0 0.3 0.1 10/23/2005 12:00:00 16.4 0.9 17.9 12.2 16.6 1.1 18.3 11.8 352 3 348 305 0.1 0 0.3 0.1 10/23/2005 12:10:00 16.4 1.2 18.7 12.2 16.7 1.3 19.1 13 348 3 349 305 0 0 0.6 -0.1 10/23/2005 12:20:00 16 1.2 18.7 11.5 16.3 1.3 18.7 11.5 349 4 350 305 -0.1 0 0.1 -0.1 10/23/2005 12:30:00 15.3 1.1 17.2 11.1 15.5 1.3 18.3 11.8 350 5 352 305 0 0 0.1 -0.1 10/23/2005 12:40:00 14.7 1.2 17.6 11.1 15 1.3 17.9 11.1 351 5 355 305 0.1 0 0.6 0.1 10/23/2005 12:50:00 15.1 1 17.2 12.2 15.4 1 17.6 12.2 349 4 352 305 0 0 0.3 -0.1 10/23/2005 13:00:00 15.5 1 17.6 11.8 15.8 1.1 18.3 11.8 350 3 350 305 0 0 0.3 0.1 10/23/2005 13:10:00 15 1 17.6 11.1 15.3 1 17.9 11.5 350 5 350 305 0.1 0 0.3 0.1 10/23/2005 13:20:00 14.9 1 17.2 12.6 15.1 1.1 17.6 12.2 351 4 348 305 0.2 0 0.3 0.1 10/23/2005 13:30:00 15.2 1 17.6 12.2 15.6 1.2 17.9 12.6 350 4 347 305 0.1 0 0.3 0.1 10/23/2005 13:40:00 14.9 1.2 17.2 11.1 15.2 1.3 17.9 11.5 353 4 354 305 0.1 0 0.3 0.1 10/23/2005 13:50:00 15.1 1.3 17.9 11.1 15.4 1.3 18.3 11.5 350 3 353 305 0.1 0 0.6 0.1 10/23/2005 14:00:00 15.6 1.1 17.9 11.8 15.9 1.2 19.1 11.8 349 4 344 305 0.1 0.1 0.6 0.1 10/23/2005 14:10:00 15 1.1 17.6 11.8 15.2 1.2 17.9 11.8 350 4 354 305 0.1 0.1 0.6 0.1 10/23/2005 14:20:00 15.5 1 17.6 12.6 15.8 1.1 17.6 12.6 349 4 353 305 0.1 0.1 0.6 0.1 10/23/2005 14:30:00 15.6 1 17.6 12.2 15.9 1.2 18.3 12.6 349 4 352 305 0.1 0.1 0.6 0.1 10/23/2005 14:40:00 15.5 1.1 17.9 12.2 15.8 1.1 18.7 13 349 4 351 305 0.2 0.1 0.6 0.1 10/23/2005 14:50:00 15.2 1.3 17.6 11.1 15.5 1.4 18.3 11.5 349 3 347 305 0.2 0.1 0.6 0.1 10/23/2005 15:00:00 14.9 1.1 17.2 11.5 15.2 1.2 17.6 11.8 353 4 356 305 0.2 0.1 0.6 0.1 10/23/2005 15:10:00 14.2 1.3 17.6 10.3 14.4 1.3 17.6 10.7 350 5 346 305 0.4 0 1 0.1 10/23/2005 15:20:00 14.6 1.2 17.2 11.5 14.8 1.3 17.9 11.8 349 4 345 305 0.4 0.1 1 0.1 10/23/2005 15:30:00 15.4 0.9 17.2 12.2 15.7 1.1 17.9 12.2 353 4 351 305 0.2 0.1 0.8 0.1 10/23/2005 15:40:00 14.9 1.2 17.2 11.5 15.1 1.2 17.6 11.8 353 5 353 305 0.1 0.1 0.6 0.1 10/23/2005 15:50:00 14.5 1.3 17.2 10.7 14.8 1.5 17.6 10.7 351 5 341 305 0.2 0.1 0.6 0.1 10/23/2005 16:00:00 14.7 1.1 17.2 11.1 14.9 1.2 17.6 11.8 346 4 344 305 0 0 0.6 -0.1 10/23/2005 16:10:00 15.5 1 17.2 11.8 15.7 1.2 18.3 12.2 347 3 347 305 0 0 0.6 -0.1 10/23/2005 16:20:00 15.2 1 17.6 11.5 15.4 1.1 17.6 11.8 344 4 344 305 0 0 0.1 -0.1 10/23/2005 16:30:00 14.9 1.2 16.8 11.1 15.2 1.3 17.6 11.8 347 4 346 305 0 0 0.1 -0.1 10/23/2005 16:40:00 15 1.1 17.6 11.1 15.3 1.3 17.9 11.1 346 4 348 305 -0.1 0 0.1 -0.4 10/23/2005 16:50:00 15.4 1.2 17.6 11.1 15.6 1.3 18.3 11.5 349 4 354 305 -0.1 0 0.3 -0.4 10/23/2005 17:00:00 15.1 1.3 17.6 11.8 15.3 1.3 18.3 12.2 344 5 337 305 -0.1 0 0.3 -0.4 10/23/2005 17:10:00 15.4 1 17.9 11.8 15.7 1.2 18.7 12.6 350 3 350 305 -0.1 0 0.3 -0.4 10/23/2005 17:20:00 14.8 1.2 17.9 10.3 15.1 1.4 18.3 10.3 345 5 333 305 -0.1 0 0.3 -0.4 10/23/2005 17:30:00 14.9 1.4 17.9 11.5 15.1 1.5 18.7 11.8 342 5 347 305 -0.1 0 0.6 -0.1 10/23/2005 17:40:00 15.8 1.2 17.9 11.5 16.1 1.4 18.7 11.8 345 4 341 305 -0.1 0 0.3 -0.4 10/23/2005 17:50:00 14.9 1.3 18.3 11.5 15.2 1.5 19.1 11.5 344 5 344 305 -0.1 0 0.3 -0.4 10/23/2005 18:00:00 14.8 1.2 17.9 11.5 15 1.3 18.3 11.8 345 5 341 305 -0.1 0 0.1 -0.1 10/23/2005 18:10:00 15.2 1.3 18.7 12.2 15.5 1.4 19.5 12.2 344 5 339 305 -0.1 0 0.1 -0.4 10/23/2005 18:20:00 15.2 1.2 17.6 11.5 15.5 1.3 17.9 12.2 345 5 339 305 -0.3 0 0.1 -0.4 10/23/2005 18:30:00 15.3 1.3 17.6 11.5 15.6 1.3 18.3 11.8 345 4 347 305 -0.3 0 0.3 -0.4 10/23/2005 18:40:00 15.4 1.3 17.9 11.5 15.5 1.4 18.7 10.3 345 5 343 305 -0.3 0 0.3 -0.4 10/23/2005 18:50:00 15.1 1 17.6 11.8 15.4 1.2 17.9 11.5 349 5 351 305 -0.3 0.1 0.3 -0.4 10/23/2005 19:00:00 15.4 1.1 17.9 12.2 15.6 1.2 18.7 12.2 346 4 347 305 -0.4 0.1 0.1 -0.6 10/23/2005 19:10:00 15.3 1.3 17.6 11.1 15.6 1.5 18.3 10.7 348 4 346 305 -0.4 0.1 0.1 -0.6 10/23/2005 19:20:00 15.2 1.2 17.9 11.5 15.4 1.3 18.3 12.2 345 5 347 305 -0.4 0.1 0.1 -0.6 10/23/2005 19:30:00 15.7 1.2 19.1 12.6 16 1.4 19.5 12.2 346 5 345 305 -0.4 0.1 0.3 -0.6 10/23/2005 19:40:00 15 1.3 17.6 11.5 15.3 1.4 18.7 11.5 349 5 345 305 -0.5 0.1 0.1 -0.6 10/23/2005 19:50:00 15.3 1.3 18.3 11.5 15.7 1.4 19.5 11.5 349 4 344 305 -0.6 0 0.1 -0.8 10/23/2005 20:00:00 15.6 1.2 18.7 11.8 15.9 1.3 19.5 12.2 345 4 346 305 -0.7 0 -0.1 -0.8 10/23/2005 20:10:00 15 1.2 17.9 12.2 15.2 1.3 18.3 11.8 343 5 338 305 -0.7 0 -0.1 -0.8 10/23/2005 20:20:00 15 1.4 18.7 11.1 15.4 1.4 18.7 11.5 344 4 336 305 -0.6 0 -0.1 -0.8 10/23/2005 20:30:00 13.8 1.2 16.4 11.1 14.1 1.3 17.2 10.7 340 6 340 305 -0.6 0 0.1 -0.6 10/23/2005 20:40:00 14.2 1.2 17.9 10.7 14.5 1.3 17.9 11.1 343 5 341 305 -0.7 0 -0.1 -0.8 10/23/2005 20:50:00 14.2 1.3 16.8 10.3 14.6 1.3 17.6 10.3 342 5 340 305 -0.7 0 -0.6 -0.8 10/23/2005 21:00:00 13.9 1.4 17.2 9.9 14.2 1.5 17.6 9.9 345 6 346 305 -0.7 0 -0.4 -0.8 10/23/2005 21:10:00 14 1.2 16.4 10.7 14.4 1.3 17.2 11.5 344 5 345 305 -0.6 0 -0.4 -0.8 10/23/2005 21:20:00 14 1.1 16.4 11.1 14.4 1.2 17.6 11.5 344 5 347 305 -0.7 0 -0.6 -0.8 10/23/2005 21:30:00 14.2 1.1 16.4 10.7 14.6 1.2 17.2 10.3 342 6 343 305 -0.7 0 -0.4 -0.8 10/23/2005 21:40:00 14.1 1 16.4 11.5 14.4 1 17.2 12.2 345 4 347 305 -0.7 0 -0.6 -0.8 10/23/2005 21:50:00 14 1.2 16.4 11.1 14.4 1.3 17.2 11.5 344 4 339 305 -0.7 0 -0.6 -0.8 10/23/2005 22:00:00 13.3 1 16.4 9.9 13.6 1 16.4 11.1 346 5 343 305 -0.6 0 -0.6 -0.6 10/23/2005 22:10:00 13.1 1.5 15.6 9.1 13.5 1.5 16.1 9.5 345 4 349 305 -0.7 0 -0.6 -0.8 10/23/2005 22:20:00 13.3 1.5 17.2 9.9 13.6 1.5 16.8 9.5 348 6 354 305 -0.7 0 -0.6 -0.8 10/23/2005 22:30:00 12.8 0.9 15.3 10.3 13.2 1 15.6 10.7 349 4 347 305 -0.7 0 -0.6 -1.1 10/23/2005 22:40:00 12.5 1.2 15.3 9.5 12.9 1.2 16.1 9.9 345 4 344 305 -0.7 0 -0.6 -0.8 10/23/2005 22:50:00 12.4 1 15.3 9.9 12.7 1.2 16.1 9.9 344 5 338 305 -0.7 0 -0.6 -0.8 10/23/2005 23:00:00 12.9 0.9 15.3 11.1 13.3 1 15.6 9.5 342 4 343 305 -0.7 0 -0.6 -0.8 10/23/2005 23:10:00 13.4 1.1 16.1 10.7 13.7 1.2 16.8 10.7 342 5 340 305 -0.7 0 -0.1 -0.8 10/23/2005 23:20:00 13 1.1 15.6 9.9 13.4 1.2 16.1 9.5 347 5 345 305 -0.7 0 -0.1 -0.8 10/23/2005 23:30:00 13 1.1 15.6 9.5 13.5 1.2 16.4 10.3 346 5 348 305 -0.7 0 -0.1 -0.8 10/23/2005 23:40:00 13 1.1 15.6 9.9 13.4 1.2 15.6 9.1 343 4 341 305 -0.7 0 -0.1 -0.8 10/23/2005 23:50:00 13.1 1 15.3 10.3 13.6 1 16.1 10.3 342 5 343 305 -0.8 0 -0.4 -1.1 10/24/2005 00:00:00 12.8 1.1 14.9 9.5 13.1 1.2 15.6 10.3 341 6 338 305 -0.8 0 -0.4 -1.1 10/24/2005 00:10:00 12.6 1 15.3 9.9 13 1 16.1 10.3 341 4 339 305 -0.8 0 -0.4 -1.1 10/24/2005 00:20:00 12.7 1.2 16.1 9.5 13 1.3 16.1 9.9 338 5 334 305 -0.8 0 -0.4 -1.1 10/24/2005 00:30:00 13.2 1 15.6 9.9 13.5 1 16.4 10.3 340 5 344 305 -0.8 0 -0.4 -1.1 10/24/2005 00:40:00 12.7 1 15.3 9.9 13.1 1 15.6 9.5 344 6 341 305 -0.8 0 -0.4 -1.1 10/24/2005 00:50:00 13.5 1 15.6 10.3 13.8 1.1 15.6 10.3 347 5 344 305 -0.8 0 -0.4 -1.1 10/24/2005 01:00:00 12.8 1 15.3 9.9 13.3 1 15.6 10.7 348 5 345 305 -0.8 0 -0.6 -1.1 10/24/2005 01:10:00 13.1 0.9 15.6 10.7 13.5 1 16.4 9.9 345 5 347 305 -0.8 0 -0.6 -1.1 10/24/2005 01:20:00 13.4 0.8 15.6 11.5 13.8 0.9 15.6 10.3 346 4 341 305 -0.8 0 -0.6 -1.1 10/24/2005 01:30:00 13.5 1 15.3 9.9 14 1 16.4 10.3 346 4 348 305 -0.8 0 -0.6 -1.1 10/24/2005 01:40:00 13.2 0.9 14.9 10.7 13.5 1 15.6 10.3 344 4 343 305 -0.9 0 -0.6 -1.1 10/24/2005 01:50:00 12.9 0.8 14.9 9.9 13.3 0.9 15.6 9.9 343 5 339 305 -0.9 0 -0.6 -1.1 10/24/2005 02:00:00 12.8 1.2 15.6 9.5 13.1 1.3 16.1 9.5 342 6 338 305 -0.8 0 -0.6 -1.1 10/24/2005 02:10:00 12.4 0.9 14.9 10.3 12.8 0.9 15.3 10.3 339 5 338 305 -0.9 0 -0.6 -1.1 10/24/2005 02:20:00 12.3 1 14.9 9.5 12.7 1 15.3 9.9 344 4 334 305 -0.8 0 -0.6 -1.1 10/24/2005 02:30:00 13 0.9 15.3 10.3 13.3 1 16.1 10.7 342 4 336 305 -1 0 -0.8 -1.1 10/24/2005 02:40:00 12.4 0.9 14.5 9.9 12.9 0.9 15.3 9.5 343 5 334 305 -1 0 -0.8 -1.1 10/24/2005 02:50:00 12.2 1 14.1 9.5 12.6 1.1 15.3 9.5 340 4 343 305 -1.1 0 -0.8 -1.1 10/24/2005 03:00:00 12.2 1 14.9 9.1 12.6 1.1 15.3 9.9 341 5 331 305 -1 0 -0.8 -1.1 10/24/2005 03:10:00 12 1 14.9 9.9 12.3 1 15.6 10.3 343 4 348 305 -1 0 -0.6 -1.1 10/24/2005 03:20:00 12 1.1 14.5 8.8 12.4 1.2 14.9 9.1 343 5 338 305 -1 0.1 -0.6 -1.1 10/24/2005 03:30:00 12.4 1 14.9 8.8 12.7 1 15.3 9.1 346 5 348 305 -1 0 -0.6 -1.1 10/24/2005 03:40:00 12.7 1 14.9 9.1 13 1 15.3 9.5 346 5 344 305 -1 0 -0.4 -1.1 10/24/2005 03:50:00 12.3 1 14.9 9.5 12.7 1 15.6 9.9 350 5 348 305 -0.8 0 -0.4 -1.1 10/24/2005 04:00:00 11.7 1.1 14.5 8.4 12.2 1.1 14.9 9.5 345 5 337 305 -0.9 0 -0.6 -1.1 10/24/2005 04:10:00 12 0.8 14.1 9.5 12.4 0.9 14.5 9.9 350 5 347 305 -0.9 0 -0.4 -1.1 10/24/2005 04:20:00 11.9 1 14.5 9.1 12.3 1 14.9 9.5 348 6 351 305 -0.9 0 -0.4 -1.1 10/24/2005 04:30:00 11.9 0.7 13.3 9.9 12.4 0.8 14.1 9.9 350 6 352 305 -1 0 -0.6 -1.1 10/24/2005 04:40:00 11.6 0.8 13.3 9.9 12 0.9 14.1 9.9 349 6 340 305 -0.9 0 -0.4 -1.1 10/24/2005 04:50:00 12.6 0.8 15.3 9.9 13.1 0.9 16.1 9.9 349 4 346 305 -1 0 -0.6 -1.1 10/24/2005 05:00:00 12.4 0.9 14.5 10.3 12.8 1 14.9 9.9 350 5 349 305 -1 0 -0.6 -1.1 10/24/2005 05:10:00 12.3 1 14.5 9.9 12.8 1 15.3 10.3 355 4 350 305 -1 0.1 -0.6 -1.1 10/24/2005 05:20:00 12.1 1 14.5 9.1 12.4 1.1 15.6 9.5 357 6 346 305 -0.9 0 -0.4 -1.1 10/24/2005 05:30:00 11.6 0.9 13.7 9.5 12 0.9 14.5 9.5 352 5 355 305 -1 0 -0.4 -1.1 10/24/2005 05:40:00 11.5 0.9 13.3 8.4 11.8 1 14.1 8.8 351 5 349 305 -1 0 -0.6 -1.1 10/24/2005 05:50:00 11.8 1 14.1 9.1 12.2 1 14.9 9.9 354 3 351 305 -1 0.1 -0.6 -1.1 10/24/2005 06:00:00 11.5 0.9 13.3 8.8 11.9 1 14.5 9.1 353 5 355 305 -1.1 0 -0.8 -1.1 10/24/2005 06:10:00 11.8 1.1 14.5 8.8 12.1 1.2 14.9 8.8 353 6 351 305 -1 0 -0.8 -1.1 10/24/2005 06:20:00 11.4 1.3 14.9 8 11.9 1.3 15.3 8.8 355 5 354 305 -1.1 0 -0.8 -1.1 10/24/2005 06:30:00 11.8 0.8 14.1 9.1 12.3 1 14.9 9.1 353 6 336 305 -1.1 0 -0.8 -1.1 10/24/2005 06:40:00 11.6 0.7 13.7 9.5 12 0.9 14.5 9.1 349 5 344 305 -1.1 0 -1.1 -1.3 10/24/2005 06:50:00 11.2 1 13.7 8 11.6 1.1 14.5 8.4 352 5 345 305 -1 0 -0.8 -1.1 10/24/2005 07:00:00 11.9 0.8 13.7 9.9 12.3 0.9 14.9 9.5 354 5 346 305 -1 0 -0.8 -1.1 10/24/2005 07:10:00 12.1 1 14.1 9.5 12.5 1 14.9 9.5 353 5 351 305 -1 0 -0.8 -1.1 10/24/2005 07:20:00 11.9 1 14.5 9.9 12.3 1.1 15.3 9.5 350 5 343 305 -1.1 0 -0.8 -1.1 10/24/2005 07:30:00 11.6 1 14.5 8.8 12 1.2 14.9 8.8 351 5 347 305 -1.1 0 -0.8 -1.3 10/24/2005 07:40:00 11.5 0.8 13 8.8 12 0.8 13.7 9.1 350 6 347 305 -1.1 0 -0.8 -1.1 10/24/2005 07:50:00 11.6 0.9 13.7 8.4 12 1 14.5 8.8 347 4 350 305 -1.1 0 -1.1 -1.3 10/24/2005 08:00:00 11.5 1 14.5 8.4 11.9 1 14.9 9.1 348 5 347 305 -1.1 0 -1.1 -1.3 10/24/2005 08:10:00 11.5 0.8 13 8.8 12 0.8 13.7 9.1 346 5 342 305 -1.1 0 -0.6 -1.3 10/24/2005 08:20:00 11 0.9 13.3 8 11.4 0.9 14.1 8.8 348 5 350 305 -1.1 0 -0.8 -1.3 10/24/2005 08:30:00 11.3 0.8 13 8.8 11.8 0.9 14.1 9.5 347 4 354 305 -1.1 0 -0.6 -1.3 10/24/2005 08:40:00 11.4 1 13.3 8 11.8 1 13.7 9.5 346 5 343 305 -1.1 0 -0.6 -1.3 10/24/2005 08:50:00 11.4 0.9 13.7 9.1 11.8 1 14.9 9.1 351 5 357 305 -1.1 0 -1.1 -1.3 10/24/2005 09:00:00 11 0.8 13.3 8.8 11.4 0.9 13.3 8.8 346 5 348 305 -1.1 0 -0.6 -1.3 10/24/2005 09:10:00 10.8 0.8 12.6 8 11.1 0.9 13 8 346 6 344 305 -1.1 0 -0.8 -1.1 10/24/2005 09:20:00 11.1 0.8 13.3 8.4 11.5 0.9 13.7 9.1 346 5 345 305 -1.1 0 -0.6 -1.1 10/24/2005 09:30:00 11.3 0.9 14.1 8.8 11.7 0.9 14.1 8.4 348 4 349 305 -1.1 0 -0.8 -1.3 10/24/2005 09:40:00 11.2 1 13.7 9.1 11.6 1.1 14.1 8.8 357 5 0 305 -1.1 0 -0.6 -1.1 10/24/2005 09:50:00 11.4 0.8 13.3 8.8 11.9 0.9 14.1 9.1 354 5 350 305 -1.1 0 -0.8 -1.1 10/24/2005 10:00:00 10.7 0.7 12.2 8.8 11.2 0.7 12.6 8.8 353 5 350 305 -1.1 0 -0.6 -1.1 10/24/2005 10:10:00 10.8 0.8 13 8.8 11.2 0.9 13.7 9.1 359 4 358 305 -1 0.1 -0.6 -1.1 10/24/2005 10:20:00 10.3 0.9 12.6 6.8 10.7 1 13 7.2 358 4 358 305 -1 0.1 -0.4 -1.1 10/24/2005 10:30:00 10 0.7 12.2 8 10.4 0.8 12.2 8.4 355 6 355 305 -1 0 -0.8 -1.1 10/24/2005 10:40:00 10.5 0.9 12.2 8.4 10.9 1 13 8.4 351 3 352 305 -1 0 -0.8 -1.1 10/24/2005 10:50:00 10 0.9 11.8 8 10.4 0.9 12.2 8 357 7 351 305 -0.9 0 -0.6 -1.1 10/24/2005 11:00:00 9.6 1 11.5 6.5 10 1 11.8 7.2 356 5 359 305 -1 0 -0.6 -1.1 10/24/2005 11:10:00 9.4 0.7 11.1 7.2 9.9 0.8 11.8 7.6 354 4 356 305 -1 0 -0.8 -1.1 10/24/2005 11:20:00 9.7 0.7 11.1 7.6 10.1 0.7 11.8 7.6 358 5 357 305 -1.1 0 -1.1 -1.3 10/24/2005 11:30:00 9.4 0.7 11.1 6.8 9.8 0.7 11.5 7.2 355 6 354 305 -1.1 0 -0.6 -1.3 10/24/2005 11:40:00 9.1 0.7 10.7 6.8 9.6 0.7 11.1 7.2 352 4 351 305 -1.1 0 -1.1 -1.3 10/24/2005 11:50:00 8.9 0.7 10.7 7.2 9.3 0.8 11.1 7.6 349 6 355 305 -1.1 0 -1.1 -1.3 10/24/2005 12:00:00 8.9 0.8 11.1 6.5 9.4 0.9 11.8 6.8 349 5 342 305 -1.1 0 -1.1 -1.3 10/24/2005 12:10:00 8.6 0.8 10.3 6.5 9 0.8 11.1 7.2 354 7 345 305 -1.1 0 -1.1 -1.1 10/24/2005 12:20:00 9.1 0.8 11.5 7.6 9.6 0.8 11.8 7.6 354 6 358 305 -1.1 0 -0.8 -1.3 10/24/2005 12:30:00 8.7 0.7 10.3 6.8 9.1 0.7 11.1 7.2 356 5 350 305 -1.1 0 -0.8 -1.3 10/24/2005 12:40:00 8.3 0.8 9.9 6.1 8.8 0.8 10.7 6.5 1 6 6 305 -1.1 0 -0.8 -1.1 10/24/2005 12:50:00 8.5 0.7 10.3 6.8 9 0.8 11.1 7.2 1 5 5 305 -1 0 -0.6 -1.1 10/24/2005 13:00:00 8.2 0.8 9.9 5.7 8.7 0.8 10.3 6.1 359 5 358 305 -1 0 -0.6 -1.1 10/24/2005 13:10:00 8.2 0.8 10.3 6.1 8.6 0.8 11.5 6.5 358 6 11 305 -1 0 -0.8 -1.1 10/24/2005 13:20:00 7.9 0.8 10.3 6.1 8.3 0.8 10.3 6.5 359 6 0 305 -1 0 -0.4 -1.1 10/24/2005 13:30:00 8.1 0.8 10.3 6.5 8.6 0.8 10.7 6.8 358 4 0 305 -0.8 0 -0.4 -1.1 10/24/2005 13:40:00 8.1 0.8 9.9 6.1 8.6 0.8 10.3 6.8 353 6 352 305 -0.9 0 -0.4 -1.1 10/24/2005 13:50:00 7.6 0.6 9.5 5.7 8.1 0.6 10.3 6.5 359 5 3 305 -0.9 0 -0.4 -1.1 10/24/2005 14:00:00 8.4 0.8 10.3 6.1 8.9 0.9 10.7 6.1 359 6 1 305 -0.7 0 -0.4 -0.8 10/24/2005 14:10:00 8.6 0.8 11.1 6.1 8.9 0.9 10.7 6.1 3 5 11 305 -0.8 0 -0.1 -1.1 10/24/2005 14:20:00 8.8 0.6 10.7 6.5 9.2 0.7 11.1 7.2 3 7 357 305 -0.8 0 -0.1 -1.1 10/24/2005 14:30:00 9.4 0.8 11.5 7.2 9.8 0.8 11.5 7.2 1 4 0 305 -0.7 0 -0.1 -0.8 10/24/2005 14:40:00 9.3 0.6 11.1 8 9.7 0.6 11.5 8 6 4 8 305 -0.7 0 -0.1 -0.8 10/24/2005 14:50:00 8.3 0.7 9.9 6.5 8.8 0.7 10.3 6.8 4 5 5 305 -0.7 0 -0.4 -1.1 10/24/2005 15:00:00 8.4 0.7 10.3 6.8 8.8 0.8 10.7 6.8 359 4 5 305 -0.7 0 -0.6 -1.1 10/24/2005 15:10:00 7.9 0.7 9.5 6.1 8.4 0.7 9.9 6.5 0 4 357 305 -0.8 0 -0.6 -1.1 10/24/2005 15:20:00 7.4 0.8 9.9 6.1 7.9 0.8 10.7 6.1 0 6 358 305 -0.7 0 -0.6 -1.1 10/24/2005 15:30:00 7.7 0.7 9.1 6.1 8.1 0.8 9.9 6.1 4 5 359 305 -0.7 0 -0.4 -0.8 10/24/2005 15:40:00 8.7 0.8 10.7 6.8 9.1 0.8 11.1 7.2 5 6 5 305 -0.7 0 -0.6 -0.8 10/24/2005 15:50:00 8.8 0.7 11.1 6.8 9.1 0.7 11.1 6.8 5 5 5 305 -0.7 0 -0.1 -1.1 10/24/2005 16:00:00 8.5 0.7 10.3 7.2 8.9 0.7 10.3 7.2 5 4 5 305 -0.8 0 -0.4 -1.1 10/24/2005 16:10:00 8.2 0.7 10.3 6.1 8.5 0.7 10.3 6.8 9 4 10 305 -0.8 0 -0.6 -1.1 10/24/2005 16:20:00 7.7 0.7 9.5 5.7 8.1 0.7 9.5 6.1 6 6 3 305 -0.8 0 -0.6 -1.1 10/24/2005 16:30:00 7.6 0.8 9.9 6.1 8 0.8 9.9 6.1 9 4 8 305 -0.9 0 -0.4 -1.1 10/24/2005 16:40:00 8.5 1.1 10.7 5.7 8.9 1.1 11.1 6.1 4 5 9 305 -0.8 0 -0.6 -1.1 10/24/2005 16:50:00 8.3 0.7 9.5 5.7 8.8 0.8 10.3 6.1 5 7 359 305 -0.8 0 -0.6 -1.1 10/24/2005 17:00:00 7.8 0.7 9.9 6.5 8.2 0.7 10.7 6.1 10 5 12 305 -0.8 0 -0.6 -1.1 10/24/2005 17:10:00 8.5 0.6 9.9 6.8 8.8 0.6 10.3 6.8 6 6 3 305 -0.8 0 -0.6 -1.1 10/24/2005 17:20:00 8.2 1 10.7 5.3 8.6 1 11.1 6.1 7 9 7 305 -0.9 0 -0.6 -1.1 10/24/2005 17:30:00 8.1 0.8 11.1 6.1 8.5 0.8 11.5 6.1 6 5 11 305 -0.9 0 -0.6 -1.1 10/24/2005 17:40:00 8.8 0.8 10.3 6.5 9.1 0.8 10.7 6.8 8 3 9 305 -0.9 0 -0.6 -1.1 10/24/2005 17:50:00 8.5 0.6 10.3 6.5 8.9 0.7 11.1 6.8 7 5 7 305 -1 0 -0.6 -1.1 10/24/2005 18:00:00 8.7 0.7 10.7 7.2 9.1 0.7 11.1 7.6 10 6 14 305 -0.9 0 -0.6 -1.1 10/24/2005 18:10:00 9 0.8 11.1 7.2 9.3 0.7 11.5 7.2 9 5 13 305 -0.9 0 -0.4 -1.1 10/24/2005 18:20:00 8.9 0.8 11.1 7.2 9.3 0.8 11.5 7.6 14 4 13 305 -1 0 -0.4 -1.1 10/24/2005 18:30:00 8.7 0.9 10.7 6.8 9.1 0.9 11.1 6.5 12 6 14 305 -1 0 -0.6 -1.1 10/24/2005 18:40:00 8.7 0.7 11.5 7.2 9.1 0.7 11.8 7.2 6 6 15 305 -1 0 -0.4 -1.1 10/24/2005 18:50:00 8.8 1.1 12.2 5.7 9.1 1.1 12.2 6.8 10 6 1 305 -0.9 0 -0.6 -1.1 10/24/2005 19:00:00 9.1 0.6 10.7 7.2 9.5 0.6 11.1 7.6 8 5 16 305 -1 0 -0.4 -1.1 10/24/2005 19:10:00 9.1 0.8 10.7 6.8 9.4 0.9 11.1 7.2 6 5 5 305 -1 0 -0.6 -1.1 10/24/2005 19:20:00 9.2 0.8 11.1 6.8 9.6 0.9 11.5 7.2 4 6 2 305 -1 0 -0.6 -1.1 10/24/2005 19:30:00 9.5 0.9 13 7.6 9.8 1 13.3 7.2 8 6 0 305 -1.1 0 -0.6 -1.1 10/24/2005 19:40:00 9.2 0.8 11.5 7.2 9.6 0.9 11.8 7.2 7 5 12 305 -1.1 0 -1.1 -1.3 10/24/2005 19:50:00 9.1 0.6 10.7 7.6 9.5 0.7 11.1 6.8 2 7 11 305 -1.1 0 -0.6 -1.3 10/24/2005 20:00:00 9.4 0.8 11.8 7.2 9.8 0.9 12.2 7.6 357 5 358 305 -1.2 0 -1.1 -1.3 10/24/2005 20:10:00 8.8 0.7 10.3 6.5 9.1 0.7 11.1 6.8 6 6 5 305 -1.2 0 -1.1 -1.3 10/24/2005 20:20:00 8.7 0.7 10.7 6.5 9.1 0.7 11.1 6.8 2 6 357 305 -1.3 0 -1.1 -1.3 10/24/2005 20:30:00 8.6 0.6 10.3 6.8 9 0.7 10.7 6.5 3 4 0 305 -1.3 0 -1.1 -1.3 10/24/2005 20:40:00 8.4 0.6 9.9 6.8 8.8 0.6 10.3 7.2 1 5 3 305 -1.3 0 -1.1 -1.3 10/24/2005 20:50:00 8.8 0.8 10.7 6.5 9.2 0.8 11.1 7.2 6 5 15 305 -1.1 0 -1.1 -1.3 10/24/2005 21:00:00 8.8 0.7 10.3 6.5 9.2 0.7 11.1 7.2 4 5 5 305 -1.2 0 -1.1 -1.3 10/24/2005 21:10:00 9.4 0.8 11.1 6.8 9.8 0.9 11.8 7.2 5 5 10 305 -1.1 0 -1.1 -1.3 10/24/2005 21:20:00 9.4 0.7 11.5 7.6 9.7 0.7 11.8 8 9 5 0 305 -1.1 0 -0.8 -1.1 10/24/2005 21:30:00 9.4 0.8 11.5 7.2 9.8 0.8 11.8 7.6 10 5 11 305 -1.1 0 -0.8 -1.1 10/24/2005 21:40:00 9.1 0.8 11.1 7.2 9.5 0.9 11.8 6.8 7 6 11 305 -1.1 0 -0.8 -1.1 10/24/2005 21:50:00 9.2 0.7 11.5 7.2 9.6 0.8 11.5 7.2 5 6 9 305 -1.1 0 -0.8 -1.1 10/24/2005 22:00:00 9 0.8 11.5 7.2 9.4 0.9 11.8 7.6 7 5 12 305 -1.1 0 -0.6 -1.3 10/24/2005 22:10:00 9.2 0.8 11.1 6.8 9.5 0.8 11.5 7.2 8 5 8 305 -1.1 0 -1.1 -1.3 10/24/2005 22:20:00 9.4 0.7 12.2 8 9.9 0.8 12.6 8.4 5 6 6 305 -1.1 0 -1.1 -1.3 10/24/2005 22:30:00 9.8 0.9 11.8 7.2 10.1 1 12.2 8 8 5 8 305 -1.1 0 -0.6 -1.3 10/24/2005 22:40:00 9.9 1 12.6 7.6 10.2 1 13.3 8 9 6 8 305 -1.1 0 -0.8 -1.3 10/24/2005 22:50:00 9 1.1 11.8 6.1 9.3 1.1 11.8 6.8 12 6 8 305 -1.1 0 -0.8 -1.3 10/24/2005 23:00:00 9.4 0.7 11.1 7.6 9.8 0.8 11.5 7.2 15 4 20 305 -1.1 0 -0.6 -1.3 10/24/2005 23:10:00 9.8 0.9 12.2 7.2 10.1 0.8 12.6 8 12 4 4 305 -1.1 0 -0.6 -1.3 10/24/2005 23:20:00 9.4 0.8 11.8 6.5 9.8 0.8 12.2 7.2 12 5 11 305 -1.1 0 -0.6 -1.3 10/24/2005 23:30:00 8.9 0.8 11.1 6.8 9.2 0.9 11.8 6.8 10 6 14 305 -1.1 0 -1.1 -1.3 10/24/2005 23:40:00 9 1 11.1 6.5 9.4 1 11.5 6.8 4 5 7 305 -1.1 0 -0.6 -1.3 10/24/2005 23:50:00 9.1 1.1 11.8 6.5 9.5 1.1 12.6 6.5 8 5 359 305 -1.1 0 -1.1 -1.3 10/25/2005 00:00:00 8.9 0.8 11.1 6.8 9.2 0.9 11.8 7.2 5 5 358 305 -1.1 0 -0.6 -1.3 10/25/2005 00:10:00 9.4 1.1 13 7.2 9.7 1.1 12.6 7.2 10 5 9 305 -1.1 0 -0.8 -1.1 10/25/2005 00:20:00 10.5 0.9 12.2 8 10.9 0.9 12.6 8.4 6 5 8 305 -1.1 0 -0.8 -1.1 10/25/2005 00:30:00 10.4 0.8 12.6 8.4 10.7 0.8 12.6 8.4 3 6 4 305 -1.1 0 -0.8 -1.1 10/25/2005 00:40:00 10 0.9 13 8.4 10.4 0.9 13.3 8.4 5 5 11 305 -1 0 -0.8 -1.1 10/25/2005 00:50:00 10.1 0.9 12.6 8 10.3 0.9 13 8.4 5 5 4 305 -0.9 0 -0.6 -1.1 10/25/2005 01:00:00 10.3 0.8 12.6 8 10.7 0.9 13 8.8 1 5 6 305 -1 0 -0.8 -1.1 10/25/2005 01:10:00 10.4 0.8 12.2 8.4 10.8 0.9 13 8.8 4 5 5 305 -1 0 -0.8 -1.1 10/25/2005 01:20:00 10.5 1 13.3 8.4 10.8 1.1 14.1 8.4 2 4 2 305 -1 0 -0.8 -1.1 10/25/2005 01:30:00 9.9 1 12.2 7.6 10.2 1.1 13 7.6 7 6 7 305 -1 0 -0.8 -1.1 10/25/2005 01:40:00 9.6 1 13 7.2 10 1 13 7.2 0 4 359 305 -1 0 -0.8 -1.1 10/25/2005 01:50:00 10.6 1.1 12.6 8 11 1.2 13.3 7.6 1 5 13 305 -1 0 -0.8 -1.1 10/25/2005 02:00:00 10.4 0.8 12.6 8.8 10.7 0.9 13.3 8.4 3 4 0 305 -1 0 -0.6 -1.1 10/25/2005 02:10:00 10.9 1 13 7.2 11.2 1.1 13.3 8 1 4 2 305 -1 0 -0.8 -1.1 10/25/2005 02:20:00 10.6 0.9 12.6 8 10.9 0.9 13 8.4 0 5 359 305 -1 0 -0.8 -1.1 10/25/2005 02:30:00 10.8 1 12.6 8 11.1 1 13 8.4 359 4 358 305 -1 0 -0.6 -1.1 10/25/2005 02:40:00 11.3 0.9 13 8.8 11.6 0.9 13.7 8.8 0 5 8 305 -1 0 -0.6 -1.1 10/25/2005 02:50:00 10.7 0.9 12.6 8 11 1 13 8.4 1 5 354 305 -1 0 -0.6 -1.1 10/25/2005 03:00:00 10.4 0.9 12.6 8 10.7 0.9 13.3 8.4 1 4 358 305 -1 0 -0.6 -1.1 10/25/2005 03:10:00 10.5 0.9 12.6 8.4 10.8 1 13 8 5 5 6 305 -1 0 -0.6 -1.1 10/25/2005 03:20:00 10.5 0.7 12.2 8.4 10.8 0.7 12.6 9.1 5 5 7 305 -1 0 -0.6 -1.1 10/25/2005 03:30:00 10.3 0.9 12.2 8.4 10.6 0.9 12.6 8.8 7 5 1 305 -1 0 -0.6 -1.1 10/25/2005 03:40:00 10.7 0.8 12.6 8 11 0.9 12.6 8.4 9 4 6 305 -1 0 -0.6 -1.1 10/25/2005 03:50:00 10.3 0.9 12.2 8 10.7 1 13 8.4 5 5 2 305 -0.9 0 -0.4 -1.1 10/25/2005 04:00:00 10.4 0.8 13 8.4 10.7 0.8 13.3 8 9 5 8 305 -0.9 0 -0.6 -1.1 10/25/2005 04:10:00 10.5 0.8 12.2 8.4 10.8 0.9 13 8.4 7 5 5 305 -0.9 0 -0.6 -1.1 10/25/2005 04:20:00 10.7 0.9 12.6 7.6 11 1 13 8.4 5 4 5 305 -1 0 -0.8 -1.1 10/25/2005 04:30:00 10.5 0.7 12.2 8.4 10.8 0.8 12.6 8.4 6 4 5 305 -1 0 -0.6 -1.1 10/25/2005 04:40:00 10.2 0.7 11.8 7.6 10.6 0.9 12.6 8 0 5 359 305 -1.1 0 -1.1 -1.1 10/25/2005 04:50:00 9.6 0.9 11.5 6.8 10 0.9 11.8 7.6 4 5 358 305 -1.1 0 -0.8 -1.3 10/25/2005 05:00:00 9.2 0.7 11.5 7.2 9.6 0.7 11.8 7.2 2 6 0 305 -1.1 0 -1.1 -1.1 10/25/2005 05:10:00 9.3 0.8 11.5 7.6 9.6 0.8 12.2 7.6 1 6 6 305 -1.1 0 -1.1 -1.3 10/25/2005 05:20:00 9.1 0.7 10.7 7.6 9.6 0.7 11.1 8 0 4 357 305 -1.1 0 -1.1 -1.3 10/25/2005 05:30:00 9.2 0.7 10.7 7.2 9.5 0.7 11.5 7.6 0 6 1 305 -1 0 -0.8 -1.1 10/25/2005 05:40:00 9.9 0.7 12.2 8 10.3 0.8 12.2 8.4 0 4 4 305 -1 0 -0.8 -1.1 10/25/2005 05:50:00 10.4 1 12.6 7.6 10.8 1 13 7.6 1 4 5 305 -1.1 0 -0.6 -1.3 10/25/2005 06:00:00 10.2 0.9 12.2 8 10.5 1 13 8 359 5 3 305 -1.1 0 -1.1 -1.1 10/25/2005 06:10:00 10.7 0.7 13 8.8 11 0.7 12.6 8.4 0 4 355 305 -1.1 0 -1.1 -1.3 10/25/2005 06:20:00 11.4 0.7 13.3 9.5 11.8 0.8 14.1 9.1 356 3 354 305 -1.1 0 -1.1 -1.3 10/25/2005 06:30:00 10.9 0.7 12.6 8.8 11.3 0.8 12.6 8.8 2 4 0 305 -1.1 0 -0.8 -1.3 10/25/2005 06:40:00 10.6 0.8 12.6 8.8 10.9 0.8 13 8.4 4 4 358 305 -1.1 0 -0.8 -1.3 10/25/2005 06:50:00 10.6 0.9 13 8.8 10.9 0.9 13.3 8.4 3 4 0 305 -1.1 0 -1.1 -1.3 10/25/2005 07:00:00 10.5 0.9 12.6 7.6 11 0.9 13 8 0 4 2 305 -1.1 0 -0.6 -1.3 10/25/2005 07:10:00 10.3 0.8 12.6 8.8 10.7 0.8 12.6 8.4 2 6 9 305 -1.1 0 -0.6 -1.3 10/25/2005 07:20:00 9.7 0.8 11.8 7.6 10 0.8 12.2 7.6 2 6 353 305 -1.1 0 -0.8 -1.1 10/25/2005 07:30:00 10.4 0.8 12.2 8.4 10.7 0.8 13 8 4 4 359 305 -1.1 0 -0.4 -1.1 10/25/2005 07:40:00 10.3 0.8 12.2 8.4 10.6 0.8 12.6 8.4 9 6 3 305 -1 0.1 -0.4 -1.1 10/25/2005 07:50:00 10.7 0.7 12.6 8.8 10.9 0.8 12.6 8 9 6 13 305 -1 0 -0.4 -1.1 10/25/2005 08:00:00 10.2 0.8 12.2 8 10.4 0.8 12.6 8.4 10 4 11 305 -1 0 -0.8 -1.1 10/25/2005 08:10:00 10.4 0.8 12.2 8.8 10.8 1 12.6 8.4 8 3 6 305 -1.1 0 -0.6 -1.1 10/25/2005 08:20:00 10 0.9 12.6 7.6 10.3 1.1 13.3 8 8 5 5 305 -1.1 0 -0.6 -1.1 10/25/2005 08:30:00 9.3 1 12.6 6.8 9.7 1 12.6 6.8 8 5 9 305 -1.1 0 -0.4 -1.1 10/25/2005 08:40:00 10.3 1 12.6 8 10.6 1.1 13.3 8.4 6 6 14 305 -1 0 -0.8 -1.1 10/25/2005 08:50:00 9.5 0.8 11.8 7.6 9.8 0.8 12.6 7.6 6 6 8 305 -1.1 0 -0.6 -1.1 10/25/2005 09:00:00 9.4 0.7 11.1 7.2 9.7 0.8 11.8 7.2 0 6 2 305 -1 0 -0.6 -1.1 10/25/2005 09:10:00 9.4 1 11.8 6.8 9.8 1.1 12.6 6.8 5 5 0 305 -1 0 -0.6 -1.1 10/25/2005 09:20:00 10 0.8 12.2 8 10.4 0.8 12.2 8.4 7 5 358 305 -1 0 -0.8 -1.1 10/25/2005 09:30:00 9.5 1 12.2 7.2 9.8 1 11.8 7.2 7 8 11 305 -1 0 -0.8 -1.1 10/25/2005 09:40:00 9.8 0.9 11.8 6.8 10.1 0.9 11.8 6.8 10 3 12 305 -1.1 0 -0.8 -1.3 10/25/2005 09:50:00 9.5 1.1 11.8 7.2 9.8 1.1 12.2 7.2 8 5 15 305 -1.1 0 -0.8 -1.1 10/25/2005 10:00:00 9.1 0.8 11.5 7.2 9.4 0.8 11.8 7.6 2 5 10 305 -1.1 0 -0.6 -1.3 10/25/2005 10:10:00 9.2 0.9 11.1 7.2 9.6 0.9 11.5 7.6 7 6 8 305 -1.1 0 -0.8 -1.1 10/25/2005 10:20:00 9.1 0.8 10.7 7.2 9.4 0.8 11.1 7.2 9 6 12 305 -0.9 0 -0.6 -1.1 10/25/2005 10:30:00 10 1.2 12.6 6.8 10.3 1.2 13 6.8 13 4 13 305 -0.9 0 -0.6 -1.1 10/25/2005 10:40:00 9.4 0.7 11.1 7.6 9.8 0.8 11.5 8 3 5 9 305 -1 0 -0.6 -1.1 10/25/2005 10:50:00 8.8 0.8 11.1 6.8 9.1 0.8 11.5 7.2 8 5 6 305 -0.9 0.1 -0.6 -1.1 10/25/2005 11:00:00 8.7 0.9 10.7 6.8 9.1 0.9 11.1 6.8 7 5 11 305 -1 0 -0.8 -1.1 10/25/2005 11:10:00 9 0.9 11.5 6.5 9.3 0.9 11.5 6.5 10 5 12 305 -1 0 -0.6 -1.1 10/25/2005 11:20:00 9.3 0.8 11.1 6.8 9.6 0.8 11.5 7.2 7 4 5 305 -1 0 -0.6 -1.1 10/25/2005 11:30:00 8.9 0.9 11.8 6.8 9.2 0.9 12.6 7.6 4 7 2 305 -1 0 -0.6 -1.1 10/25/2005 11:40:00 9.1 0.8 11.1 6.8 9.5 0.8 11.5 7.6 0 6 0 305 -0.8 0 -0.6 -1.1 10/25/2005 11:50:00 8.9 0.8 10.7 6.1 9.3 0.9 11.5 6.8 359 5 9 305 -0.9 0 -0.6 -1.1 10/25/2005 12:00:00 8.8 0.9 11.5 6.5 9.2 0.9 11.8 6.8 357 5 2 305 -0.8 0 -0.4 -1.1 10/25/2005 12:10:00 9.1 0.8 11.1 7.2 9.5 0.8 11.5 7.6 355 5 353 305 -0.9 0 -0.6 -1.1 10/25/2005 12:20:00 9 0.7 10.7 7.2 9.4 0.7 11.1 7.6 359 5 11 305 -1 0 -0.6 -1.1 10/25/2005 12:30:00 8.6 1 11.5 6.1 9 1 11.8 6.8 2 7 352 305 -0.9 0 -0.6 -1.1 10/25/2005 12:40:00 8.5 1 11.5 6.5 8.8 0.9 12.2 7.2 2 5 9 305 -0.9 0 -0.6 -1.1 10/25/2005 12:50:00 8.6 0.9 10.7 6.1 9 0.9 11.1 6.5 1 5 2 305 -0.8 0 -0.4 -1.1 10/25/2005 13:00:00 8.4 0.9 10.7 6.5 8.7 0.9 10.7 6.1 5 6 0 305 -0.8 0 -0.4 -1.1 10/25/2005 13:10:00 8.6 1.1 10.7 6.5 9 1.1 11.1 6.5 0 6 0 305 -0.8 0 -0.4 -1.1 10/25/2005 13:20:00 8.1 0.8 9.5 5.7 8.5 0.8 9.9 6.5 8 8 12 305 -0.9 0 -0.4 -1.1 10/25/2005 13:30:00 8.2 0.6 9.5 5.7 8.5 0.6 10.3 6.8 3 8 8 305 -0.8 0 -0.4 -1.1 10/25/2005 13:40:00 8.3 1.1 10.3 5.7 8.7 1.1 11.1 6.1 6 6 12 305 -0.8 0 -0.4 -1.1 10/25/2005 13:50:00 8.1 0.9 10.3 6.1 8.5 0.9 11.1 6.1 2 6 356 305 -0.9 0 -0.6 -1.1 10/25/2005 14:00:00 8.2 0.7 9.9 6.5 8.6 0.7 10.3 6.8 4 5 8 305 -0.8 0 -0.6 -1.1 10/25/2005 14:10:00 8.1 0.7 9.9 6.5 8.5 0.7 10.3 6.8 3 5 358 305 -0.8 0 -0.6 -1.1 10/25/2005 14:20:00 8.3 0.6 10.3 6.8 8.7 0.6 10.7 7.2 4 5 7 305 -0.7 0 -0.4 -1.1 10/25/2005 14:30:00 8.6 0.8 10.7 6.5 9 0.8 11.1 6.8 4 5 5 305 -0.5 0.1 -0.4 -0.8 10/25/2005 14:40:00 8.9 0.7 10.7 7.2 9.4 0.7 11.1 7.6 3 4 5 305 -0.7 0 -0.4 -0.8 10/25/2005 14:50:00 8.4 0.8 10.7 6.5 8.7 0.9 11.1 6.5 4 5 0 305 -0.7 0 -0.6 -1.1 10/25/2005 15:00:00 8.9 0.7 11.1 6.8 9.3 0.8 11.1 7.2 0 5 352 305 -0.8 0 -0.6 -1.1 10/25/2005 15:10:00 8.6 0.5 10.3 7.2 9 0.6 11.1 6.8 2 5 4 305 -0.7 0 -0.6 -0.8 10/25/2005 15:20:00 8.3 0.8 10.7 6.1 8.6 0.9 11.1 6.8 358 5 359 305 -0.7 0 -0.4 -0.8 10/25/2005 15:30:00 8.3 0.7 9.9 6.5 8.7 0.7 10.3 6.8 2 5 354 305 -0.7 0 -0.6 -0.8 10/25/2005 15:40:00 8.4 0.8 10.3 6.5 8.7 0.8 11.5 6.5 1 6 351 305 -0.7 0 -0.4 -0.8 10/25/2005 15:50:00 8.5 0.5 9.9 7.2 8.9 0.6 10.7 7.2 358 5 352 305 -0.7 0 -0.6 -0.8 10/25/2005 16:00:00 8.3 0.6 9.5 6.8 8.7 0.6 9.9 7.2 0 7 8 305 -0.7 0 -0.4 -0.8 10/25/2005 16:10:00 7.9 0.6 9.5 6.5 8.3 0.6 9.9 6.5 1 4 2 305 -0.7 0 -0.4 -1.1 10/25/2005 16:20:00 7.7 0.8 9.1 5.7 8 0.8 9.9 6.1 3 5 0 305 -0.8 0 -0.4 -1.1 10/25/2005 16:30:00 7.6 0.7 9.5 5.3 8 0.7 9.9 6.1 4 4 7 305 -0.8 0 -0.4 -1.1 10/25/2005 16:40:00 7.5 0.5 8.8 6.5 8 0.5 9.1 6.5 1 4 4 305 -1 0 -0.6 -1.1 10/25/2005 16:50:00 7.3 0.6 9.1 5.7 7.7 0.6 9.1 6.1 359 5 3 305 -0.9 0 -0.4 -1.1 10/25/2005 17:00:00 7.1 0.6 9.1 5.7 7.6 0.6 9.9 6.5 0 5 6 305 -1 0 -0.6 -1.1 10/25/2005 17:10:00 7.2 0.6 9.5 6.1 7.7 0.6 9.9 6.5 3 7 7 305 -1 0 -0.4 -1.1 10/25/2005 17:20:00 7.3 0.5 8.8 5.7 7.7 0.6 9.1 5.7 4 4 4 305 -1 0 -0.6 -1.1 10/25/2005 17:30:00 7 0.6 8 5.3 7.5 0.6 9.1 6.1 1 4 357 305 -1 0 -0.6 -1.1 10/25/2005 17:40:00 7.2 0.6 8.4 5.7 7.7 0.6 9.1 6.5 358 3 357 305 -1.1 0 -0.6 -1.1 10/25/2005 17:50:00 6.8 0.6 8.4 5.3 7.3 0.6 8.8 5.7 356 6 346 305 -1.1 0 -1.1 -1.1 10/25/2005 18:00:00 7.2 0.6 8.8 5.3 7.6 0.7 9.1 5.7 359 5 1 305 -1.1 0 -0.8 -1.1 10/25/2005 18:10:00 7 0.6 8.4 4.6 7.4 0.6 8.8 5.7 4 6 0 305 -1.1 0 -0.6 -1.1 10/25/2005 18:20:00 6.7 0.7 8.4 5.3 7.2 0.7 9.1 5.3 6 4 10 305 -1.1 0 -0.8 -1.1 10/25/2005 18:30:00 6.9 0.6 8.4 5.3 7.3 0.6 8.8 5.7 3 6 7 305 -1.1 0 -0.8 -1.1 10/25/2005 18:40:00 6.4 0.7 8.4 4.6 6.8 0.8 8.8 4.9 6 5 4 305 -1 0 -0.8 -1.1 10/25/2005 18:50:00 6.2 0.6 7.2 4.2 6.7 0.6 7.6 4.6 5 3 2 305 -1.1 0 -1.1 -1.1 10/25/2005 19:00:00 5.8 0.8 8 4.2 6.2 0.8 8.4 4.6 9 7 352 305 -1.1 0 -1.1 -1.1 10/25/2005 19:10:00 5.6 0.6 8 4.2 6 0.7 8.8 4.6 8 6 10 305 -1.1 0 -1.1 -1.1 10/25/2005 19:20:00 5.1 0.6 6.5 3.8 5.4 0.7 6.8 3.8 3 6 355 305 -1.1 0 -0.8 -1.1 10/25/2005 19:30:00 5.4 0.6 6.8 3.8 5.7 0.5 6.8 4.2 12 6 10 305 -1.1 0 -0.8 -1.1 10/25/2005 19:40:00 5.2 0.7 7.2 3.4 5.6 0.6 7.2 4.2 10 6 18 305 -1 0 -0.8 -1.1 10/25/2005 19:50:00 5.5 0.8 7.2 3.8 5.7 0.7 7.2 4.2 15 6 9 305 -1 0 -0.8 -1.1 10/25/2005 20:00:00 5.4 0.6 6.8 4.2 5.6 0.6 7.2 4.2 20 7 15 305 -1 0 -0.8 -1.1 10/25/2005 20:10:00 5 0.5 6.1 4.2 5.2 0.5 6.5 3.8 20 7 22 305 -1 0 -0.8 -1.1 10/25/2005 20:20:00 5.5 0.6 7.2 4.2 5.8 0.7 7.6 4.2 20 6 24 305 -1.1 0 -0.8 -1.1 10/25/2005 20:30:00 5.9 0.6 7.2 4.2 6.1 0.6 7.6 4.6 16 6 15 305 -1 0 -0.8 -1.1 10/25/2005 20:40:00 5.3 0.6 6.8 3.8 5.7 0.6 7.2 4.2 3 4 6 305 -1.1 0 -0.8 -1.1 10/25/2005 20:50:00 5.3 0.6 6.8 4.2 5.7 0.6 7.2 4.2 7 5 7 305 -1.1 0 -1.1 -1.3 10/25/2005 21:00:00 5 0.6 6.5 3.8 5.4 0.6 6.8 4.2 8 6 8 305 -1.1 0 -0.8 -1.3 10/25/2005 21:10:00 4.6 0.5 6.1 3 4.9 0.5 6.1 3 21 5 19 305 -1.1 0 -0.6 -1.3 10/25/2005 21:20:00 4 0.7 6.1 2.6 4.2 0.8 6.1 2.6 12 7 13 305 -1.2 0 -0.6 -1.3 10/25/2005 21:30:00 4.1 0.6 5.7 2.6 4.3 0.7 6.1 3 10 11 359 305 -1.2 0 -0.6 -1.3 10/25/2005 21:40:00 4 0.5 5.7 3 4.1 0.6 5.7 2.6 17 6 12 305 -1.2 0 -1.1 -1.3 10/25/2005 21:50:00 4.3 0.5 5.7 3 4.4 0.6 5.7 3 7 9 4 305 -1.2 0 -0.6 -1.3 10/25/2005 22:00:00 3.5 0.5 4.6 2.3 3.7 0.5 4.9 2.6 19 7 19 305 -1.2 0 -1.1 -1.3 10/25/2005 22:10:00 3.7 0.6 5.3 2.6 4 0.6 5.7 3 2 8 9 305 -1.3 0 -1.1 -1.3 10/25/2005 22:20:00 3.4 0.5 5.3 2.3 3.7 0.5 5.7 2.6 4 7 358 305 -1.2 0 -0.8 -1.3 10/25/2005 22:30:00 3.2 0.8 5.3 1.5 3.4 0.7 5.7 1.9 5 8 14 305 -1.2 0 -1.1 -1.3 10/25/2005 22:40:00 3.4 0.7 5.7 1.9 3.6 0.8 5.7 2.3 0 10 352 305 -1.4 0 -1.1 -1.3 10/25/2005 22:50:00 4 0.8 5.7 1.9 4.3 0.9 6.1 2.3 351 7 347 305 -1.3 0 -1.1 -1.3 10/25/2005 23:00:00 3.7 0.6 4.9 2.3 4.1 0.6 5.3 2.6 347 6 343 305 -1.4 0 -0.8 -1.5 10/25/2005 23:10:00 3.6 0.6 4.9 2.3 3.9 0.6 4.9 2.6 350 9 352 305 -1.4 0 -1.3 -1.5 10/25/2005 23:20:00 2.8 0.5 4.6 1.5 3.1 0.5 4.6 1.9 339 8 359 305 -1.5 0 -1.3 -1.8 10/25/2005 23:30:00 3.2 0.8 4.6 1.5 3.4 0.8 4.9 1.9 347 10 333 305 -1.4 0 -1.3 -1.8 10/25/2005 23:40:00 3.2 0.6 4.9 1.9 3.5 0.6 4.9 2.3 354 6 347 305 -1.4 0 -1.1 -1.5 10/25/2005 23:50:00 3.6 0.6 4.9 2.3 4 0.6 5.3 2.3 350 9 350 305 -1.4 0 -1.1 -1.5 10/26/2005 00:00:00 2.6 0.6 4.2 1.1 3 0.6 4.9 1.9 331 7 329 305 -1.5 0.1 -1.1 -1.8 10/26/2005 00:10:00 3.5 0.5 4.6 2.3 3.8 0.5 4.9 2.6 344 6 356 305 -1.4 0 -0.8 -1.5 10/26/2005 00:20:00 3 0.5 4.2 1.5 3.3 0.5 4.6 1.9 333 17 347 305 -1.4 0 -0.6 -1.5 10/26/2005 00:30:00 3.2 0.5 4.2 1.9 3.4 0.5 4.9 2.3 324 9 336 305 -1.5 0.1 -1.1 -1.8 10/26/2005 00:40:00 2.6 0.6 3.8 1.1 2.9 0.5 4.2 1.9 324 10 339 305 -1.4 0.1 -0.8 -1.8 10/26/2005 00:50:00 3.2 0.4 4.2 1.9 3.6 0.5 4.6 2.3 339 10 334 305 -1.4 0 -0.8 -1.8 10/26/2005 01:00:00 2.9 0.5 4.2 1.5 3.2 0.6 4.6 1.9 336 13 345 305 -1.4 0.1 -0.8 -1.5 10/26/2005 01:10:00 2.5 0.6 3.8 1.1 2.9 0.5 4.2 1.9 337 5 331 305 -1.5 0.1 -0.8 -1.8 10/26/2005 01:20:00 3 0.5 4.2 1.9 3.3 0.5 4.6 2.3 320 8 324 305 -1.6 0.1 -1.1 -1.8 10/26/2005 01:30:00 3.1 0.6 4.2 1.5 3.5 0.6 4.9 1.9 336 7 339 305 -1.5 0 -1.1 -1.8 10/26/2005 01:40:00 3.4 0.8 4.6 1.5 3.7 0.8 4.9 1.9 319 12 330 305 -1.5 0.1 -0.8 -1.8 10/26/2005 01:50:00 3.2 0.6 4.6 1.9 3.6 0.6 5.3 2.3 317 8 320 305 -1.4 0 -0.8 -1.5 10/26/2005 02:00:00 3.3 0.6 4.9 1.5 3.5 0.6 4.9 2.3 314 6 316 305 -1.5 0.1 -1.1 -1.8 10/26/2005 02:10:00 3 0.5 4.2 1.9 3.2 0.4 4.2 2.3 310 10 305 305 -1.6 0.1 -1.1 -2 10/26/2005 02:20:00 3.4 0.7 4.9 1.9 3.7 0.7 5.7 2.3 318 9 325 305 -1.6 0.1 -0.8 -1.8 10/26/2005 02:30:00 1.9 1.1 4.2 0.4 2.3 1 4.9 0.7 328 13 313 305 -1.3 0 -0.8 -1.5 10/26/2005 02:40:00 2.9 0.8 4.6 1.5 3.2 0.9 5.3 1.9 336 7 341 305 -1.4 0 -0.8 -1.5 10/26/2005 02:50:00 2.5 1 4.9 0.7 2.7 0.8 4.9 1.1 317 12 305 305 -1.4 0 -0.8 -1.5 10/26/2005 03:00:00 3.2 0.5 4.2 1.9 3.3 0.5 4.2 2.3 294 5 294 305 -1.5 0 -1.1 -1.8 10/26/2005 03:10:00 2.4 0.8 3.8 0.7 2.6 0.8 4.2 1.1 319 18 333 305 -1.5 0 -1.1 -1.8 10/26/2005 03:20:00 3.1 0.5 4.2 1.9 3.4 0.5 4.6 2.3 323 6 325 305 -1.4 0 -1.3 -1.5 10/26/2005 03:30:00 2.1 0.8 3.4 0.4 2.6 0.7 3.8 0.7 312 7 315 305 -1.5 0 -1.3 -1.8 10/26/2005 03:40:00 1.8 0.8 3.4 0.4 2.2 0.6 3.4 1.1 325 11 312 305 -1.5 0 -1.3 -1.8 10/26/2005 03:50:00 2.2 0.5 3 0.7 2.7 0.5 3.4 1.5 324 8 317 305 -1.7 0.1 -1.3 -2 10/26/2005 04:00:00 0.9 0.6 3 0.4 1.6 0.4 3 0.7 323 10 308 305 -1.6 0.1 -1.1 -2 10/26/2005 04:10:00 2.6 0.8 4.2 0.7 3 0.7 4.2 1.5 312 8 309 305 -2.2 0 -1.5 -2.4 10/26/2005 04:20:00 2.9 0.4 3.8 1.9 3.2 0.3 3.8 2.3 309 12 306 305 -2.1 0.1 -1.5 -2.2 10/26/2005 04:30:00 2.1 0.6 3.4 0.7 2.5 0.5 3.8 1.5 317 8 317 305 -1.8 0.2 -1.1 -2.2 10/26/2005 04:40:00 0.5 0.3 1.5 0.4 1.1 0.4 1.9 0.4 310 14 310 305 -1.5 0 -1.1 -1.8 10/26/2005 04:50:00 1.9 0.6 3.4 0.7 2.2 0.5 3.4 1.1 304 6 305 305 -2.1 0.3 -1.3 -2.7 10/26/2005 05:00:00 1.2 0.4 2.3 0.4 1.6 0.4 2.6 0.7 301 13 308 305 -2.6 0.1 -2.4 -2.7 10/26/2005 05:10:00 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 272 0 272 305 -2.3 0.2 -1.8 -2.7 10/26/2005 05:20:00 0.5 0.4 1.9 0.4 0.9 0.4 1.9 0.4 273 18 234 305 -2.2 0 -2 -2.4 10/26/2005 05:30:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.7 252 14 239 305 -2.3 0 -2.2 -2.4 10/26/2005 05:40:00 0.8 0.4 1.9 0.4 1 0.3 1.9 0.4 257 6 261 305 -2.5 0.1 -2.2 -2.7 10/26/2005 05:50:00 1.1 0.5 2.3 0.4 1.4 0.4 2.3 0.4 278 22 302 305 -2.6 0 -2.2 -2.7 10/26/2005 06:00:00 1.3 0.6 2.6 0.4 1.7 0.4 2.6 1.1 294 12 287 305 -2.6 0.1 -2.2 -2.7 10/26/2005 06:10:00 0.7 0.4 1.5 0.4 1.1 0.4 1.9 0.4 292 12 273 305 -2.8 0 -2.4 -3.1 10/26/2005 06:20:00 0.8 0.4 1.5 0.4 0.9 0.3 1.9 0.4 254 15 283 305 -2.9 0 -2.7 -3.1 10/26/2005 06:30:00 0.5 0.3 1.9 0.4 0.8 0.4 1.9 0.4 240 20 232 305 -2.8 0 -2.7 -2.9 10/26/2005 06:40:00 0.8 0.3 1.5 0.4 1.3 0.4 1.9 0.4 181 3 182 305 -2.7 0.1 -2.4 -3.1 10/26/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 212 22 213 305 -3.1 0.3 -2.7 -3.8 10/26/2005 07:00:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 211 2 305 305 -3.7 0.1 -3.1 -4 10/26/2005 07:10:00 0.4 0 0.7 0.4 1 0.2 1.5 0.4 186 0 186 305 -3.3 0 -2.9 -3.3 10/26/2005 07:20:00 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 180 1 305 305 -3.1 0.1 -2.9 -3.3 10/26/2005 07:30:00 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 183 4 305 305 -3.1 0 -2.9 -3.3 10/26/2005 07:40:00 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 177 2 305 305 -3.4 0 -3.1 -3.8 10/26/2005 07:50:00 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 177 0 305 305 -3.9 0 -3.3 -4 10/26/2005 08:00:00 0.5 0.2 1.1 0.4 1.5 0.2 1.9 0.7 153 8 147 305 -3.6 0 -3.3 -3.8 10/26/2005 08:10:00 0.5 0.2 1.1 0.4 1.6 0.2 1.9 1.1 147 0 147 305 -3.5 0 -3.3 -3.8 10/26/2005 08:20:00 0.6 0.3 1.9 0.4 1.8 0.3 2.6 1.1 148 3 144 305 -3.3 0 -3.1 -3.6 10/26/2005 08:30:00 0.6 0.3 1.5 0.4 1.7 0.2 2.3 1.1 147 0 147 305 -3.3 0 -3.1 -3.3 10/26/2005 08:40:00 1 0.3 1.9 0.4 1.9 0.2 2.3 1.1 150 2 152 305 -3.3 0 -3.3 -3.6 10/26/2005 08:50:00 0.4 0.2 1.1 0.4 1.4 0.3 1.9 0.7 151 0 151 305 -3.3 0 -3.1 -3.6 10/26/2005 09:00:00 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 158 10 305 305 -3.5 0 -3.3 -3.8 10/26/2005 09:10:00 0.4 0.2 1.1 0.4 1 0.3 1.9 0.4 176 5 181 305 -3.5 0 -3.3 -3.8 10/26/2005 09:20:00 1 0.4 1.9 0.4 1.6 0.3 2.3 1.1 185 5 188 305 -3.5 0.2 -3.1 -3.8 10/26/2005 09:30:00 1.2 0.4 2.3 0.4 1.9 0.3 2.6 1.5 178 4 185 305 -3.2 0 -2.9 -3.3 10/26/2005 09:40:00 1.1 0.4 1.9 0.4 1.7 0.2 2.3 1.1 177 2 179 305 -3.2 0 -3.1 -3.3 10/26/2005 09:50:00 1 0.3 1.5 0.4 1.7 0.4 2.3 0.7 179 0 180 305 -3.3 0.1 -3.1 -3.6 10/26/2005 10:00:00 0.9 0.3 1.5 0.4 1.5 0.3 2.3 0.7 178 2 183 305 -3.7 0.1 -3.3 -3.8 10/26/2005 10:10:00 0.8 0.4 1.5 0.4 1.3 0.3 1.9 0.4 179 0 179 305 -3.4 0 -3.3 -3.6 10/26/2005 10:20:00 0.4 0.1 0.7 0.4 1.1 0.3 1.9 0.4 179 0 179 305 -3.5 0.1 -3.3 -3.8 10/26/2005 10:30:00 0.7 0.3 1.5 0.4 1.5 0.2 1.9 1.1 179 0 179 305 -3.8 0 -3.6 -4 10/26/2005 10:40:00 0.6 0.3 1.5 0.4 1.4 0.2 1.9 1.1 179 0 179 305 -3.7 0 -3.3 -4 10/26/2005 10:50:00 0.8 0.3 1.5 0.4 1.7 0.4 2.3 0.4 176 4 181 305 -3.7 0.1 -3.3 -4 10/26/2005 11:00:00 1.3 0.3 1.9 0.4 1.8 0.3 2.3 0.7 181 4 184 305 -3.4 0 -2.9 -3.8 10/26/2005 11:10:00 0.9 0.2 1.5 0.4 1.6 0.2 2.3 1.1 181 0 181 305 -3.3 0 -3.3 -3.3 10/26/2005 11:20:00 0.6 0.2 1.1 0.4 1.4 0.2 1.9 1.1 181 0 181 305 -3.5 0.1 -3.1 -3.8 10/26/2005 11:30:00 0.4 0 0.4 0.4 0.9 0.2 1.5 0.7 182 0 305 305 -3 0.2 -2.2 -3.3 10/26/2005 11:40:00 0.4 0 0.4 0.4 0.8 0.2 1.5 0.4 182 0 305 305 -2.4 0 -2 -2.7 10/26/2005 11:50:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 182 0 305 305 -2.2 0.1 -1.3 -2.4 10/26/2005 12:00:00 0.4 0 0.7 0.4 0.9 0.3 1.5 0.4 182 0 183 305 -1.4 0.1 -0.6 -1.8 10/26/2005 12:10:00 0.4 0 0.4 0.4 0.9 0.2 1.1 0.4 182 0 305 305 -1.1 0.1 -0.4 -1.3 10/26/2005 12:20:00 0.5 0.3 1.5 0.4 1.3 0.4 2.3 0.7 161 8 147 305 -1.1 0.4 -0.1 -1.8 10/26/2005 12:30:00 1.1 0.4 1.9 0.4 2.1 0.4 3 1.1 161 13 150 305 -1.8 0.3 -1.3 -2.2 10/26/2005 12:40:00 1.4 0.2 1.9 1.1 2 0.2 2.3 1.5 150 0 150 305 -1.7 0.2 -1.3 -2 10/26/2005 12:50:00 1.5 0.2 1.9 1.1 2.1 0.2 2.3 1.9 150 0 150 305 -1.4 0 -1.1 -1.8 10/26/2005 13:00:00 2 0.2 2.3 1.5 2.3 0.2 2.6 1.9 150 0 150 305 -1.2 0 -1.1 -1.3 10/26/2005 13:10:00 2.1 0.2 2.6 1.9 2.5 0.2 3 2.3 150 0 150 305 -1.2 0 -0.6 -1.3 10/26/2005 13:20:00 2.1 0.4 2.6 0.7 2.6 0.2 3 2.3 150 0 150 305 -1.1 0 -1.1 -1.3 10/26/2005 13:30:00 0.9 0.4 1.9 0.4 2.3 0.2 2.6 1.9 154 3 150 305 -0.7 0.1 -0.4 -1.1 10/26/2005 13:40:00 0.6 0.3 1.5 0.4 2.1 0.2 2.6 1.9 160 1 161 305 -0.2 0.1 0.1 -0.6 10/26/2005 13:50:00 1.4 0.3 1.9 0.7 2.1 0.2 2.3 1.9 159 1 161 305 0 0 0.3 -0.1 10/26/2005 14:00:00 0.9 0.3 1.5 0.4 2.1 0.2 2.3 1.5 155 1 158 305 0.1 0 0.6 0.1 10/26/2005 14:10:00 0.4 0.1 0.7 0.4 1.9 0.2 2.3 1.5 159 3 155 305 0.4 0.1 0.6 0.1 10/26/2005 14:20:00 0.6 0.3 1.1 0.4 1.7 0.2 2.3 1.5 171 6 173 305 0.9 0.2 1.3 0.6 10/26/2005 14:30:00 1.2 0.4 1.9 0.4 1.6 0.3 2.3 1.1 183 4 180 305 0.6 0.1 1 0.3 10/26/2005 14:40:00 1.2 0.4 1.9 0.4 1.7 0.3 2.3 1.1 181 5 184 305 0.5 0 1 0.3 10/26/2005 14:50:00 0.9 0.3 1.9 0.4 1.6 0.2 2.3 1.1 185 3 184 305 0.4 0.2 1 0.1 10/26/2005 15:00:00 0.5 0.3 1.1 0.4 1.1 0.5 1.9 0.4 180 4 178 305 0.3 0.1 1 0.1 10/26/2005 15:10:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 185 5 305 305 1 0.3 1.5 0.6 10/26/2005 15:20:00 0.4 0.1 1.1 0.4 1 0.3 1.9 0.4 199 3 198 305 0.7 0.2 1.3 0.3 10/26/2005 15:30:00 0.6 0.3 1.5 0.4 1.4 0.2 1.9 0.7 215 8 212 305 0.2 0.3 1.3 -0.4 10/26/2005 15:40:00 0.4 0.2 1.1 0.4 1.3 0.2 1.9 0.7 212 5 221 305 0 0 0.3 -0.4 10/26/2005 15:50:00 0.6 0.3 1.5 0.4 1.2 0.5 2.3 0.4 181 27 196 305 0.1 0.1 0.6 -0.1 10/26/2005 16:00:00 0.5 0.3 1.9 0.4 0.7 0.5 1.9 0.4 123 18 98 305 1 0.5 2 0.1 10/26/2005 16:10:00 1.7 0.5 2.6 0.4 1.7 0.4 2.3 0.7 75 11 62 305 2 0 2.2 1.5 10/26/2005 16:20:00 1.5 0.4 2.6 0.4 1.7 0.3 2.3 1.1 69 8 67 305 1.7 0.1 2 1.5 10/26/2005 16:30:00 3.6 0.8 4.9 1.1 3.4 0.7 4.6 1.5 73 8 79 305 0.4 0.7 1.7 -0.6 10/26/2005 16:40:00 3 0.7 4.9 1.5 2.8 0.6 4.9 1.5 71 17 97 305 -0.7 0.2 -0.1 -1.1 10/26/2005 16:50:00 4 0.9 6.1 1.9 3.8 0.8 5.7 1.9 82 8 89 305 -0.8 0.1 -0.4 -1.1 10/26/2005 17:00:00 4.4 0.7 6.1 3 4.2 0.7 5.7 2.3 93 9 82 305 -1 0.1 -0.4 -1.1 10/26/2005 17:10:00 3.1 0.5 4.2 1.5 2.9 0.5 4.2 1.1 79 11 82 305 -1.1 0.1 -0.6 -1.3 10/26/2005 17:20:00 3.3 1 5.7 1.5 3.1 1 5.7 1.5 70 14 56 305 -1.1 0.1 -0.6 -1.3 10/26/2005 17:30:00 4.1 0.7 6.1 2.6 4 0.6 5.7 2.6 66 14 68 305 -1 0.2 -0.4 -1.1 10/26/2005 17:40:00 3.8 0.8 5.3 2.3 3.7 0.8 5.7 1.9 61 9 50 305 -1.1 0.1 -0.6 -1.3 10/26/2005 17:50:00 3.8 0.5 5.3 2.3 3.6 0.5 5.3 2.3 79 13 77 305 -1 0.2 -0.4 -1.1 10/26/2005 18:00:00 4.2 0.7 5.7 2.6 4 0.7 5.3 2.6 77 8 67 305 -1.1 0 -0.6 -1.3 10/26/2005 18:10:00 4.9 0.8 6.8 3.4 4.8 0.8 6.8 3.4 71 11 68 305 -1.1 0 -0.6 -1.1 10/26/2005 18:20:00 4.3 0.5 5.3 2.6 4.2 0.5 5.3 3 81 8 82 305 -1.1 0 -1.1 -1.3 10/26/2005 18:30:00 4.8 1.2 7.6 2.6 4.7 1.2 7.2 2.6 79 13 66 305 -1.1 0 -0.8 -1.3 10/26/2005 18:40:00 4.3 0.7 6.5 3 4.4 0.8 6.5 2.6 65 10 54 305 -1.1 0 -0.8 -1.1 10/26/2005 18:50:00 4 0.7 6.1 2.3 3.9 0.7 5.7 2.3 80 9 88 305 -1 0 -0.6 -1.1 10/26/2005 19:00:00 4.8 0.7 6.8 3 4.8 0.7 6.5 3 70 8 68 305 -1 0 -0.6 -1.1 10/26/2005 19:10:00 4.9 0.9 7.2 3 4.8 0.9 7.2 3 76 8 67 305 -1 0 -0.8 -1.1 10/26/2005 19:20:00 4.1 0.9 6.5 1.9 4.1 0.8 6.5 2.3 79 17 63 305 -0.9 0 -0.6 -1.1 10/26/2005 19:30:00 3.6 1 6.1 0.7 3.5 1 5.7 1.1 86 20 86 305 -0.8 0 -0.4 -1.1 10/26/2005 19:40:00 3.8 0.6 5.7 2.3 3.6 0.5 4.9 2.3 78 13 53 305 -0.8 0 -0.4 -1.1 10/26/2005 19:50:00 4 1 7.2 1.9 4 1.1 8.8 1.5 81 15 57 305 -0.6 0 0.1 -0.8 10/26/2005 20:00:00 4.9 1.2 8 2.6 4.8 1.1 7.2 2.3 78 12 74 305 -0.6 0 -0.4 -0.6 10/26/2005 20:10:00 4.9 0.9 8 3 4.9 0.8 8 3 61 7 64 305 -0.5 0 0.1 -0.6 10/26/2005 20:20:00 6.1 1.2 9.5 4.2 6 1.1 9.1 4.2 67 7 73 305 -0.5 0 0.1 -0.6 10/26/2005 20:30:00 6.8 1.3 9.5 4.2 6.7 1.5 9.5 3.8 69 11 58 305 -0.5 0.1 0.1 -0.6 10/26/2005 20:40:00 6.4 0.6 8.4 5.3 6.3 0.7 8.8 4.9 71 6 59 305 -0.4 0 0.1 -0.6 10/26/2005 20:50:00 6.3 1.3 9.1 3.4 6.1 1.3 9.5 3.8 69 8 62 305 -0.4 0.1 0.3 -0.6 10/26/2005 21:00:00 7.1 1.2 10.3 4.6 6.9 1.2 9.9 4.6 73 6 66 305 -0.4 0.1 0.1 -0.6 10/26/2005 21:10:00 6.7 1.2 10.3 4.6 6.5 1.2 10.3 4.2 78 6 68 305 -0.4 0.1 0.1 -0.4 10/26/2005 21:20:00 7.8 0.8 9.5 6.1 7.7 0.8 9.9 5.7 64 6 54 305 -0.3 0 0.3 -0.4 10/26/2005 21:30:00 6.7 0.7 8.4 4.9 6.5 0.8 8.4 4.9 70 6 66 305 -0.3 0.1 0.3 -0.4 10/26/2005 21:40:00 8.2 1.1 10.3 5.7 8.2 1.2 10.3 5.3 62 6 62 305 -0.1 0 0.3 -0.4 10/26/2005 21:50:00 7.9 0.8 10.7 6.1 7.8 0.9 10.7 5.7 68 5 62 305 -0.2 0 0.3 -0.4 10/26/2005 22:00:00 8.3 0.9 10.3 6.1 8.1 0.9 10.3 4.9 67 8 70 305 -0.1 0 0.1 -0.1 10/26/2005 22:10:00 7.4 0.8 9.1 5.3 7.4 0.8 9.1 5.3 63 8 71 305 0 0 0.1 0.1 10/26/2005 22:20:00 8.4 0.9 11.8 6.5 8.3 0.9 11.8 6.5 65 8 65 305 0.2 0 0.3 0.1 10/26/2005 22:30:00 8.7 1 11.5 6.1 8.7 1.1 11.8 6.1 64 6 62 305 0.2 0 0.6 0.1 10/26/2005 22:40:00 8.7 1.1 11.5 6.8 8.5 1.2 11.5 6.1 73 6 76 305 0 0.1 0.3 0.1 10/26/2005 22:50:00 8.6 1.2 12.2 5.7 8.6 1.3 11.8 5.7 65 6 68 305 0.1 0 0.3 0.1 10/26/2005 23:00:00 9.1 0.9 11.5 6.8 8.8 1 11.5 6.5 71 8 68 305 0.1 0 0.3 0.1 10/26/2005 23:10:00 9.8 0.7 11.5 8 9.9 0.8 11.8 7.6 60 4 64 305 0.2 0 0.3 0.1 10/26/2005 23:20:00 9.6 1 12.2 7.2 9.6 1 12.6 7.2 65 4 65 305 0.2 0 0.3 0.1 10/26/2005 23:30:00 9.1 1.3 12.6 6.5 9 1.3 12.6 6.5 68 8 67 305 0.2 0 0.3 0.1 10/26/2005 23:40:00 9.2 1.2 11.8 6.5 8.9 1.3 11.8 5.7 73 6 76 305 0.2 0 0.3 0.1 10/26/2005 23:50:00 8.6 1.1 11.5 5.7 8.2 1.1 11.1 4.9 75 7 72 305 0.1 0 0.6 0.1 10/27/2005 00:00:00 9.1 0.9 11.1 7.2 9.1 1 11.1 6.5 66 7 61 305 0.1 0.1 0.6 0.1 10/27/2005 00:10:00 9 1.1 11.5 6.5 8.8 1.3 12.6 5.7 69 7 62 305 0 0.1 0.6 -0.4 10/27/2005 00:20:00 8.7 1.1 12.6 6.5 8.5 1.2 11.5 5.7 75 6 67 305 -0.1 0 0.3 -0.4 10/27/2005 00:30:00 8.5 0.9 10.7 6.5 8.2 1 10.3 5.3 75 7 79 305 -0.1 0 0.3 -0.4 10/27/2005 00:40:00 9.5 1.1 12.6 6.1 9.4 1.2 12.2 6.1 69 5 64 305 -0.2 0.1 0.3 -0.4 10/27/2005 00:50:00 9.4 1 11.8 6.5 9.1 1 11.5 6.5 75 7 67 305 -0.2 0.1 0.3 -0.4 10/27/2005 01:00:00 9.4 1.1 12.6 6.5 9 1.2 12.6 6.1 75 7 69 305 -0.3 0.1 0.3 -0.4 10/27/2005 01:10:00 9.4 1.1 12.6 6.8 9.3 1 12.2 7.2 68 6 69 305 -0.2 0.1 0.3 -0.4 10/27/2005 01:20:00 10.5 1 13.3 8.4 10.4 1.1 13.3 8 67 5 58 305 -0.2 0.1 0.3 -0.4 10/27/2005 01:30:00 10 0.9 13.3 8 9.9 1 13 7.6 67 5 71 305 -0.3 0.1 0.3 -0.4 10/27/2005 01:40:00 8.7 1.2 12.2 4.9 8.6 1.3 11.8 4.9 69 6 70 305 -0.3 0.1 0.3 -0.4 10/27/2005 01:50:00 9.1 1 13.7 6.5 8.9 1.1 13.7 6.1 71 6 62 305 -0.3 0 0.3 -0.4 10/27/2005 02:00:00 10.2 1.1 13.7 7.6 10 1.2 13.3 7.6 68 6 64 305 -0.1 0.1 0.3 -0.4 10/27/2005 02:10:00 8.9 1.2 11.5 5.7 8.8 1.3 11.8 6.1 64 5 65 305 -0.1 0 0.6 -0.4 10/27/2005 02:20:00 10 1.1 13 6.8 9.8 1.1 13 6.1 74 10 65 305 0 0 0.3 0.1 10/27/2005 02:30:00 8.9 1.1 11.5 5.3 8.8 1.2 11.5 5.7 72 8 68 305 0 0 0.3 -0.1 10/27/2005 02:40:00 9.1 1.2 12.2 5.7 8.8 1.3 11.8 5.7 78 8 77 305 0.2 0 0.3 0.1 10/27/2005 02:50:00 9.1 1.6 13 4.9 8.9 1.6 12.2 4.6 80 13 88 305 0.3 0 0.8 0.1 10/27/2005 03:00:00 6.3 1.6 10.3 3 6 1.6 11.1 3 101 21 101 305 0.1 0 0.3 0.1 10/27/2005 03:10:00 5.5 1.4 9.5 1.9 5.3 1.3 9.1 2.3 108 29 91 305 -0.1 0 0.1 -0.4 10/27/2005 03:20:00 6.3 1.3 9.5 2.3 6.2 1.5 9.9 2.6 123 22 109 305 -0.3 0 -0.1 -0.4 10/27/2005 03:30:00 6 1.5 10.3 2.6 5.7 1.6 9.5 2.3 131 18 138 305 -0.5 0 -0.4 -0.6 10/27/2005 03:40:00 5.2 1 8.4 2.3 5.3 1 8 2.3 132 19 110 305 -0.5 0 -0.4 -0.6 10/27/2005 03:50:00 5.2 1.2 9.1 2.3 5.3 1.1 10.3 2.6 133 15 136 305 -0.5 0 -0.1 -0.6 10/27/2005 04:00:00 3.7 1.5 7.2 0.4 3.9 1.5 8 1.1 115 23 154 305 -0.4 0 0.1 -0.4 10/27/2005 04:10:00 3.8 1 6.5 1.5 3.8 1 6.5 1.9 123 17 96 305 -0.4 0 -0.4 -0.4 10/27/2005 04:20:00 3.2 1 5.3 0.4 3.4 0.9 5.3 1.1 125 17 108 305 -0.4 0 0.1 -0.6 10/27/2005 04:30:00 3.4 1.1 7.2 1.1 3.5 1.2 7.6 1.5 119 22 116 305 -0.3 0 0.3 -0.4 10/27/2005 04:40:00 3.3 1.2 6.5 0.4 3.4 1.1 6.1 0.7 128 18 127 305 -0.3 0 0.3 -0.4 10/27/2005 04:50:00 3.5 0.8 5.7 1.1 3.6 0.8 5.3 1.5 125 16 146 305 -0.3 0 0.3 -0.4 10/27/2005 05:00:00 3.5 1.1 6.5 0.7 3.8 1.1 6.5 1.1 126 21 144 305 -0.2 0 0.3 -0.4 10/27/2005 05:10:00 3.5 1.1 6.8 1.1 3.7 1.1 6.8 1.5 123 16 127 305 -0.1 0 0.3 -0.4 10/27/2005 05:20:00 4.6 0.7 6.5 2.6 4.6 0.8 6.1 2.6 131 11 124 305 0 0 0.3 -0.1 10/27/2005 05:30:00 3.5 1 6.1 0.4 3.7 1 6.5 1.5 122 15 127 305 0 0 0.6 -0.1 10/27/2005 05:40:00 2.7 1.2 5.7 0.4 2.9 1 5.3 0.4 125 22 108 305 -0.1 0 0.6 -0.1 10/27/2005 05:50:00 2.6 1.3 6.1 0.4 2.6 1 6.1 0.4 93 39 69 305 0 0 0.3 -0.1 10/27/2005 06:00:00 4.9 1.1 7.6 2.3 4.8 1.1 8 3 89 22 66 305 0.2 0 0.6 0.1 10/27/2005 06:10:00 4.4 1.2 8.4 1.9 4.4 1.1 8 2.3 100 19 113 305 0.2 0 0.6 0.1 10/27/2005 06:20:00 5.2 1.7 10.3 2.3 5.1 1.7 10.7 1.5 72 19 60 305 0.3 0 0.6 0.1 10/27/2005 06:30:00 8 1.3 12.6 4.2 7.8 1.2 12.2 4.2 76 13 57 305 0.5 0 1 0.6 10/27/2005 06:40:00 8.5 1.2 13 6.1 8.2 1.2 11.8 5.7 77 8 89 305 0.6 0 1.3 0.6 10/27/2005 06:50:00 8.5 1 11.5 5.7 8.2 1 11.1 5.7 81 6 80 305 0.6 0 0.8 0.6 10/27/2005 07:00:00 9.2 1.3 12.6 5.7 8.7 1.2 11.8 5.7 80 8 75 305 0.6 0 1 0.6 10/27/2005 07:10:00 9.7 0.9 11.8 7.6 9.5 1 11.8 7.6 73 9 81 305 0.5 0 1 0.6 10/27/2005 07:20:00 9.6 1 11.8 6.8 9.4 1 12.6 6.8 74 5 74 305 0.5 0 0.6 0.6 10/27/2005 07:30:00 9.7 0.8 12.6 7.2 9.4 0.9 11.8 6.5 76 7 73 305 0.5 0 1 0.6 10/27/2005 07:40:00 9.8 1.3 12.2 6.1 9.4 1.2 12.6 6.8 81 8 68 305 0.4 0 0.6 0.3 10/27/2005 07:50:00 9.4 1.3 12.2 5.7 9.1 1.2 11.8 5.3 76 8 84 305 0.3 0 0.8 0.1 10/27/2005 08:00:00 9.4 1 12.6 7.2 8.9 1 12.6 6.5 77 6 82 305 0.2 0 0.8 0.1 10/27/2005 08:10:00 9.2 1.1 11.8 6.5 8.8 1.2 11.8 5.3 79 7 82 305 0.2 0 0.8 0.1 10/27/2005 08:20:00 9.7 1.3 13.3 6.1 9.2 1.5 13.7 5.3 81 9 82 305 0.2 0 0.3 0.1 10/27/2005 08:30:00 9.9 1.2 13.7 7.2 9.5 1.2 13 6.5 83 7 80 305 0.1 0 0.3 0.1 10/27/2005 08:40:00 8.7 0.9 10.3 5.7 8.3 0.8 9.9 6.1 77 8 70 305 0.1 0 0.3 0.1 10/27/2005 08:50:00 9.4 1.2 13 6.1 9 1.2 12.2 5.3 74 9 67 305 0.2 0 0.3 0.1 10/27/2005 09:00:00 10.1 1 13 8 10 1 13 6.5 71 6 66 305 0.2 0 0.6 0.1 10/27/2005 09:10:00 10.8 1.1 13 7.6 10.6 1.1 13 7.6 70 4 75 305 0.2 0.1 0.8 0.1 10/27/2005 09:20:00 10.1 0.9 12.2 6.5 9.9 1 11.8 6.5 75 6 74 305 0.2 0 0.6 0.1 10/27/2005 09:30:00 10.2 1 12.6 7.2 9.8 1 12.2 6.8 80 7 81 305 0.1 0 0.6 0.1 10/27/2005 09:40:00 9.3 1.2 12.2 6.1 9 1.2 12.2 6.1 75 8 64 305 0 0 0.6 0.1 10/27/2005 09:50:00 10.2 1.1 12.6 6.5 9.9 1.2 12.6 6.5 75 7 70 305 0.3 0 0.8 0.1 10/27/2005 10:00:00 10.1 1.4 13 6.5 9.6 1.4 12.6 6.1 80 8 83 305 0.3 0 0.8 0.1 10/27/2005 10:10:00 9.1 1 11.1 6.5 8.9 1 10.7 5.3 77 6 85 305 0.3 0 1 0.1 10/27/2005 10:20:00 9.2 1.2 12.2 6.1 9.1 1.3 12.2 6.1 66 9 65 305 0.4 0 1 0.3 10/27/2005 10:30:00 10.7 1.1 13.7 8.4 10.6 1.2 14.1 7.2 62 10 61 305 0.4 0 1 0.3 10/27/2005 10:40:00 10.6 1.3 14.1 7.2 10.5 1.3 13.7 7.2 65 6 64 305 0.4 0.1 1 0.1 10/27/2005 10:50:00 10.4 1.2 13.7 8 10.4 1.3 13.3 7.6 64 4 66 305 0.4 0 1 0.3 10/27/2005 11:00:00 10.2 0.8 12.2 8.4 10.2 0.9 12.6 8 61 6 65 305 0.4 0 1 0.3 10/27/2005 11:10:00 10.5 0.8 12.2 8 10.4 0.8 12.2 8.4 64 8 56 305 0.4 0 1 0.3 10/27/2005 11:20:00 10.4 0.8 13 7.6 10.4 0.8 13 7.6 62 6 68 305 0.4 0 1 0.3 10/27/2005 11:30:00 10.7 0.8 13 8.4 10.7 0.8 12.6 8.8 56 8 60 305 0.4 0 0.6 0.3 10/27/2005 11:40:00 10.6 1.2 13 8.4 10.5 1.3 13 7.6 54 6 52 305 0.4 0 0.6 0.1 10/27/2005 11:50:00 10.7 1.2 13.7 8 10.6 1.2 13 7.6 60 6 62 305 0.4 0 0.6 0.3 10/27/2005 12:00:00 10.4 0.8 13 8 10.4 0.9 12.6 8 55 5 59 305 0.4 0 0.6 0.3 10/27/2005 12:10:00 11.1 0.8 13 8.8 11.1 0.8 13 8 57 5 59 305 0.4 0 0.6 0.3 10/27/2005 12:20:00 11 1.4 13.7 7.6 11 1.4 14.1 7.2 62 6 62 305 0.4 0 0.6 0.3 10/27/2005 12:30:00 10.6 0.8 12.2 8.4 10.6 0.8 12.2 8.4 55 4 53 305 0.4 0 0.6 0.3 10/27/2005 12:40:00 11 0.7 12.6 8.4 11 0.8 12.6 8.4 55 5 58 305 0.4 0 0.6 0.3 10/27/2005 12:50:00 10 0.7 11.5 7.6 10 0.7 11.8 7.6 57 4 57 305 0.3 0 0.6 0.3 10/27/2005 13:00:00 9.5 0.8 11.5 7.2 9.6 0.8 11.5 6.8 56 5 50 305 0.3 0 0.6 0.1 10/27/2005 13:10:00 9.4 0.8 11.5 7.2 9.4 0.8 11.8 7.2 56 5 59 305 0.3 0 0.8 0.1 10/27/2005 13:20:00 9.6 0.7 11.5 8 9.6 0.8 11.5 7.6 56 5 54 305 0.2 0 0.3 0.1 10/27/2005 13:30:00 8.6 0.8 10.7 6.1 8.6 0.9 10.7 5.7 64 9 69 305 0.3 0 0.3 0.1 10/27/2005 13:40:00 8.9 0.8 10.7 6.8 8.9 0.8 10.7 6.5 66 5 73 305 0.2 0 0.6 0.1 10/27/2005 13:50:00 9.1 0.8 11.1 7.2 9 0.8 10.7 6.5 66 4 65 305 0.2 0.1 0.8 0.1 10/27/2005 14:00:00 9.1 0.6 10.3 7.2 9 0.6 10.7 7.2 69 4 72 305 0.4 0.1 1.3 0.1 10/27/2005 14:10:00 9 0.7 10.7 6.8 8.8 0.8 10.7 6.5 72 5 71 305 0.6 0 1 0.3 10/27/2005 14:20:00 8.3 0.9 10.3 5.7 8.2 1 10.3 5.7 71 5 73 305 0.4 0 1.3 0.3 10/27/2005 14:30:00 8.5 0.7 10.3 6.5 8.3 0.7 10.3 6.5 68 5 65 305 0.7 0.1 1.3 0.6 10/27/2005 14:40:00 8.4 0.6 10.3 6.8 8.3 0.6 9.9 5.7 65 8 68 305 0.9 0 1.5 0.8 10/27/2005 14:50:00 8.5 0.6 9.9 6.8 8.5 0.7 10.3 6.5 59 7 60 305 0.7 0.2 1.3 0.6 10/27/2005 15:00:00 7.7 0.7 9.1 5.3 7.7 0.7 9.5 5.3 61 8 67 305 0.5 0 1 0.3 10/27/2005 15:10:00 7.9 0.8 9.9 6.1 8 0.9 9.9 6.1 56 7 59 305 0.5 0 1 0.3 10/27/2005 15:20:00 8 0.7 9.5 6.5 8 0.7 9.5 6.1 56 7 50 305 0.5 0 1 0.3 10/27/2005 15:30:00 7.7 0.8 9.5 5.3 7.6 0.9 9.5 5.3 70 5 65 305 0.6 0.1 1.3 0.3 10/27/2005 15:40:00 7.3 0.6 8.8 5.7 7.4 0.7 9.1 5.7 64 5 70 305 0.4 0 1 0.3 10/27/2005 15:50:00 7.2 0.8 9.5 5.3 7.4 0.9 9.9 5.3 60 8 65 305 0.4 0 0.8 0.3 10/27/2005 16:00:00 6.5 0.7 8.4 4.9 6.6 0.7 8.8 4.9 53 6 44 305 0.4 0 0.6 0.3 10/27/2005 16:10:00 7 1.2 9.9 4.9 6.9 1.1 9.5 4.9 71 8 72 305 0.3 0 0.8 0.1 10/27/2005 16:20:00 7.5 1.1 10.3 5.3 7.2 1.1 10.3 4.6 79 9 70 305 0.2 0 0.3 0.1 10/27/2005 16:30:00 7.7 0.8 10.3 5.7 7.7 1 9.9 5.3 67 7 70 305 0.1 0 0.3 0.1 10/27/2005 16:40:00 8.3 0.8 9.9 6.5 8.3 0.8 10.3 6.1 61 9 55 305 0.1 0 0.3 0.1 10/27/2005 16:50:00 8 1.2 11.8 5.3 8 1.2 11.8 5.7 62 8 51 305 0.2 0 0.3 0.1 10/27/2005 17:00:00 9.2 0.6 10.7 6.8 9.2 0.7 11.1 6.8 54 9 61 305 0.1 0 0.3 0.1 10/27/2005 17:10:00 8.7 0.9 11.1 6.5 8.6 0.9 10.7 6.5 66 5 65 305 0 0 0.1 -0.1 10/27/2005 17:20:00 8.3 0.7 9.9 6.1 8.4 0.7 9.9 6.5 56 9 58 305 0 0.1 0.3 -0.4 10/27/2005 17:30:00 9.5 1.4 12.6 6.5 9.5 1.4 12.6 6.5 56 5 59 305 0.2 0 0.6 0.1 10/27/2005 17:40:00 8.4 0.6 10.3 6.8 8.4 0.6 10.3 6.1 56 7 56 305 0.1 0 0.3 0.1 10/27/2005 17:50:00 8.6 0.9 11.1 6.8 8.6 0.9 11.1 6.1 63 6 67 305 0.2 0 0.3 0.1 10/27/2005 18:00:00 9 1 11.5 6.8 9 0.9 11.1 6.8 62 7 61 305 0.2 0 0.6 0.1 10/27/2005 18:10:00 8 0.6 9.9 6.5 8 0.7 9.9 6.1 55 9 49 305 0.3 0 0.8 0.1 10/27/2005 18:20:00 10 0.8 11.8 7.6 10 0.9 11.8 8 38 6 38 305 0.3 0 0.8 0.1 10/27/2005 18:30:00 9.5 0.6 10.7 8.4 9.5 0.7 11.1 8 39 5 40 305 0.2 0.1 0.6 0.1 10/27/2005 18:40:00 9.4 0.7 11.1 7.6 9.5 0.8 11.1 7.2 46 4 42 305 0 0 0.6 -0.1 10/27/2005 18:50:00 10.1 0.6 11.8 8.8 10.2 0.7 12.2 8 47 5 46 305 -0.1 0 0.6 -0.4 10/27/2005 19:00:00 9.6 0.9 12.2 7.6 9.6 1 11.8 7.2 42 6 43 305 -0.2 0 0.3 -0.4 10/27/2005 19:10:00 10.5 0.7 12.2 8.4 10.5 0.8 12.2 7.6 45 5 53 305 -0.3 0 0.3 -0.4 10/27/2005 19:20:00 10.1 0.9 12.2 8 10.1 1 12.6 7.6 49 5 45 305 -0.3 0 0.3 -0.4 10/27/2005 19:30:00 10.1 0.8 11.8 8 10.1 0.9 12.2 7.6 48 6 52 305 -0.4 0 0.3 -0.6 10/27/2005 19:40:00 10.2 1 12.6 8 10.2 1.1 13.3 7.2 47 6 46 305 -0.4 0 0.1 -0.6 10/27/2005 19:50:00 10.4 0.9 14.1 8.4 10.4 1 13.7 8 45 5 56 305 -0.4 0 -0.4 -0.6 10/27/2005 20:00:00 11.1 0.8 13.3 8.8 11.1 0.8 13.3 9.1 51 8 56 305 -0.5 0 0.1 -0.6 10/27/2005 20:10:00 11.1 0.8 13.7 8.8 11.2 0.8 13.3 8.4 52 5 52 305 -0.5 0 -0.4 -0.6 10/27/2005 20:20:00 11.4 0.8 13.3 9.5 11.4 0.9 13.7 8.8 50 8 50 305 -0.5 0 -0.4 -0.6 10/27/2005 20:30:00 11 0.9 12.6 8.8 11 1 13 8.8 47 6 46 305 -0.5 0 -0.4 -0.6 10/27/2005 20:40:00 11 0.9 13.3 8 10.9 1 13.3 7.2 50 6 47 305 -0.5 0 -0.1 -0.6 10/27/2005 20:50:00 10.6 1.2 13.3 7.6 10.7 1.3 14.5 7.6 48 6 46 305 -0.5 0 -0.4 -0.6 10/27/2005 21:00:00 11.2 0.7 13 8.8 11.2 0.8 13.3 8.8 50 5 56 305 -0.5 0 -0.4 -0.6 10/27/2005 21:10:00 10.6 0.8 12.6 8.8 10.6 0.8 12.2 8 52 5 54 305 -0.4 0 -0.1 -0.4 10/27/2005 21:20:00 10.5 1.1 13.7 8 10.5 1.2 14.1 8 54 6 48 305 -0.4 0 -0.1 -0.4 10/27/2005 21:30:00 10.5 1.1 13.3 7.2 10.5 1.2 13.7 6.8 44 7 46 305 -0.1 0.1 0.3 -0.4 10/27/2005 21:40:00 10.6 0.8 12.6 8.8 10.7 1 13 8 47 6 46 305 0 0 0.1 -0.1 10/27/2005 21:50:00 10.7 0.7 12.6 8.8 10.8 0.8 13 9.1 40 6 36 305 -0.1 0 0.1 -0.4 10/27/2005 22:00:00 10.2 0.7 12.6 8.8 10.2 0.8 12.6 7.6 40 6 43 305 -0.1 0 0.1 -0.4 10/27/2005 22:10:00 11.1 0.9 13 8.8 11.2 1.1 13.3 8.4 49 5 54 305 -0.2 0 0.1 -0.4 10/27/2005 22:20:00 11 0.8 13 8.8 11.1 0.8 13 9.1 50 6 52 305 -0.3 0 0.1 -0.4 10/27/2005 22:30:00 11 0.8 13 8.4 11 0.9 13.3 8.8 43 6 39 305 -0.3 0 0.1 -0.4 10/27/2005 22:40:00 10.4 0.8 12.2 8.4 10.4 1 12.6 8 49 7 50 305 -0.3 0 0.1 -0.4 10/27/2005 22:50:00 11.2 0.8 13 8.8 11.2 0.9 13.3 8.8 42 4 45 305 -0.2 0 0.1 -0.4 10/27/2005 23:00:00 11.3 0.7 12.6 9.5 11.3 0.8 13 9.1 45 4 41 305 -0.3 0 0.1 -0.4 10/27/2005 23:10:00 11.3 0.7 13 9.5 11.3 0.8 13.7 8.8 40 4 40 305 -0.3 0 0.1 -0.4 10/27/2005 23:20:00 11.1 1 13 8.4 11.2 1.1 13.3 8 46 5 40 305 -0.3 0 -0.1 -0.4 10/27/2005 23:30:00 11.7 0.8 13.7 9.5 11.7 0.9 13.7 9.5 40 5 40 305 -0.3 0 0.1 -0.4 10/27/2005 23:40:00 11.4 0.6 13 9.5 11.5 0.7 13 9.9 46 5 33 305 -0.3 0 -0.1 -0.4 10/27/2005 23:50:00 10.5 0.7 12.6 8.8 10.4 0.9 13 8.4 45 6 43 305 -0.2 0 0.1 -0.4 10/28/2005 00:00:00 10.8 0.8 13 8.8 10.9 0.9 13.3 8.8 46 6 54 305 -0.1 0 0.3 -0.4 10/28/2005 00:10:00 11.1 0.8 13 8.8 11 0.9 13.3 9.1 47 6 46 305 0.1 0 0.3 0.1 10/28/2005 00:20:00 11.7 0.8 13.7 9.5 11.8 0.9 14.1 9.5 45 3 48 305 0.1 0 0.3 0.1 10/28/2005 00:30:00 11.5 0.7 13.3 9.5 11.6 0.8 13.7 9.5 45 4 42 305 0.1 0 0.3 0.1 10/28/2005 00:40:00 11.6 0.8 13.3 9.1 11.7 0.8 13.7 9.1 38 5 42 305 0.2 0 0.3 0.1 10/28/2005 00:50:00 11.5 1.1 13.7 9.1 11.6 1.1 14.1 8.4 36 5 30 305 0.3 0 0.6 0.1 10/28/2005 01:00:00 12.3 0.8 14.1 10.3 12.4 0.9 14.5 9.9 32 4 32 305 0.4 0 0.6 0.3 10/28/2005 01:10:00 12.2 1 14.5 9.1 12.3 1.1 14.9 9.5 35 5 37 305 0.4 0 0.6 0.3 10/28/2005 01:20:00 12.1 0.7 14.1 10.3 12.2 0.8 14.5 10.3 39 4 38 305 0.3 0 0.6 0.3 10/28/2005 01:30:00 12.5 1.1 14.9 9.1 12.5 1.2 14.9 9.1 39 4 39 305 0.4 0 0.6 0.3 10/28/2005 01:40:00 12.3 0.8 14.1 9.9 12.4 0.8 14.1 9.5 41 5 45 305 0.4 0 0.6 0.3 10/28/2005 01:50:00 12.5 1 14.9 9.9 12.6 1.1 15.6 9.5 42 5 45 305 0.4 0 0.6 0.3 10/28/2005 02:00:00 13 0.7 14.9 11.1 13.1 0.7 14.9 10.7 43 3 44 305 0.4 0 0.6 0.3 10/28/2005 02:10:00 12.8 0.7 14.5 10.7 12.8 0.8 14.9 10.3 42 4 43 305 0.4 0 0.6 0.3 10/28/2005 02:20:00 12.6 0.8 14.5 9.9 12.7 1 15.3 9.5 46 5 47 305 0.4 0 0.6 0.3 10/28/2005 02:30:00 12.8 0.8 15.3 10.3 12.8 1 15.3 10.3 45 4 45 305 0.4 0 0.6 0.3 10/28/2005 02:40:00 12.9 0.8 14.5 10.7 12.9 0.9 14.9 10.7 36 5 42 305 0.4 0 0.6 0.3 10/28/2005 02:50:00 12.3 1 14.1 9.1 12.2 1.1 14.5 9.1 37 5 34 305 0.5 0 0.8 0.6 10/28/2005 03:00:00 13 1 14.9 9.9 13 1 14.9 9.9 40 5 38 305 0.5 0 0.8 0.3 10/28/2005 03:10:00 13.6 0.9 15.6 10.7 13.5 1.1 15.6 10.3 38 5 35 305 0.6 0 1 0.6 10/28/2005 03:20:00 12.6 0.8 14.5 10.3 12.6 0.9 14.9 9.9 43 5 42 305 0.7 0.1 1.3 0.6 10/28/2005 03:30:00 12.2 0.9 14.5 9.5 12.2 1 14.1 9.5 42 6 33 305 0.7 0.1 1.3 0.6 10/28/2005 03:40:00 12.3 0.9 14.1 9.9 12.3 1 14.9 9.5 43 5 51 305 0.8 0.1 1.3 0.6 10/28/2005 03:50:00 12.2 0.9 14.1 9.9 12.2 1 14.5 9.9 40 6 48 305 0.9 0 1.5 0.6 10/28/2005 04:00:00 13 0.9 14.9 9.5 13 1 15.3 9.9 34 5 34 305 1 0 1.5 0.8 10/28/2005 04:10:00 12.7 1.2 16.1 9.9 12.7 1.3 16.1 9.1 34 7 22 305 1 0 1.5 0.8 10/28/2005 04:20:00 13.7 0.9 16.4 11.5 13.8 1 16.8 11.1 27 5 29 305 1 0 1.5 0.8 10/28/2005 04:30:00 12.6 1 14.9 9.9 12.6 1.1 15.6 9.9 25 5 29 305 0.9 0 1.5 0.8 10/28/2005 04:40:00 13 1 15.3 9.9 13.2 1 15.3 9.1 24 4 22 305 0.9 0 1.5 0.8 10/28/2005 04:50:00 13.1 1 15.6 11.1 13.1 1 15.6 9.9 31 5 33 305 0.9 0 1.3 0.8 10/28/2005 05:00:00 12.5 1 14.9 9.9 12.5 1 14.9 9.5 31 7 56 305 0.9 0.1 1.3 0.6 10/28/2005 05:10:00 12.7 0.8 14.9 10.3 12.6 0.9 14.9 10.3 30 5 26 305 0.8 0 1.3 0.6 10/28/2005 05:20:00 13.1 0.9 15.6 10.7 13.3 1 16.1 11.1 22 4 23 305 0.8 0 1.3 0.6 10/28/2005 05:30:00 12.7 0.9 15.3 10.3 12.9 1 15.3 9.5 18 4 19 305 0.7 0.1 1.3 0.6 10/28/2005 05:40:00 13.1 0.9 15.6 10.7 13.2 1 16.4 10.7 21 5 24 305 0.6 0.1 1 0.6 10/28/2005 05:50:00 13.3 1.1 15.6 10.7 13.4 1.2 16.1 10.3 21 8 17 305 0.6 0 1.3 0.6 10/28/2005 06:00:00 13 1 15.3 9.5 13 1.1 15.3 10.3 27 4 28 305 0.5 0 0.8 0.3 10/28/2005 06:10:00 13.1 0.7 14.5 11.1 13.3 0.8 15.3 10.7 23 5 25 305 0.5 0 0.6 0.3 10/28/2005 06:20:00 13.5 1.1 15.6 11.1 13.5 1.2 16.4 11.1 22 5 18 305 0.5 0 0.8 0.3 10/28/2005 06:30:00 13.5 1 16.1 11.1 13.6 1.1 16.4 10.7 20 5 21 305 0.5 0 0.6 0.6 10/28/2005 06:40:00 13.4 1.2 15.6 9.1 13.5 1.3 16.1 9.5 25 7 29 305 0.5 0 0.6 0.3 10/28/2005 06:50:00 13.8 1 16.8 11.5 13.9 1 16.8 10.7 25 4 24 305 0.4 0 0.6 0.3 10/28/2005 07:00:00 13.6 1.1 16.1 10.3 13.7 1.2 16.1 10.3 25 5 18 305 0.5 0 0.6 0.3 10/28/2005 07:10:00 13.9 1.2 17.2 11.1 14 1.4 16.8 9.9 24 5 24 305 0.4 0 0.6 0.1 10/28/2005 07:20:00 12.9 0.9 15.6 9.9 13 1 15.6 9.9 28 6 27 305 0.3 0 0.6 0.1 10/28/2005 07:30:00 12.7 0.8 14.5 10.3 12.8 0.9 14.9 10.3 26 6 29 305 0.3 0 0.6 0.1 10/28/2005 07:40:00 13.1 0.9 15.3 10.7 13.2 1 15.3 10.3 20 5 20 305 0.4 0 0.6 0.1 10/28/2005 07:50:00 14 1.2 16.8 10.3 14.2 1.3 17.2 10.7 16 4 17 305 0.3 0 0.8 0.1 10/28/2005 08:00:00 14 1.2 16.4 10.3 14.1 1.3 16.4 10.7 19 5 18 305 0.1 0.1 0.6 0.1 10/28/2005 08:10:00 13 1 15.3 9.9 13.2 1.1 15.6 9.9 21 5 18 305 0 0.1 0.6 0.1 10/28/2005 08:20:00 13 1.3 16.1 9.9 13.1 1.5 16.4 9.5 25 5 22 305 0 0.1 0.6 0.1 10/28/2005 08:30:00 13.7 1.1 16.4 11.1 13.8 1.2 16.8 11.1 16 5 16 305 0 0.1 0.6 0.1 10/28/2005 08:40:00 14.3 0.8 16.4 12.2 14.5 1 16.8 12.2 16 5 21 305 0 0 0.6 -0.1 10/28/2005 08:50:00 14.1 1.2 16.8 10.7 14.3 1.2 16.8 10.3 16 4 16 305 0 0 0.6 -0.1 10/28/2005 09:00:00 13.4 0.9 16.1 10.7 13.6 1 15.6 11.1 13 4 12 305 -0.1 0 0.3 -0.4 10/28/2005 09:10:00 13.8 1 16.8 11.5 14 1 16.8 11.5 12 3 12 305 -0.1 0 0.3 -0.4 10/28/2005 09:20:00 13.9 1.1 16.1 10.3 14 1.2 16.1 9.9 14 5 21 305 -0.1 0 0.3 -0.4 10/28/2005 09:30:00 14.2 0.9 16.4 11.8 14.4 1 17.2 11.5 13 5 16 305 -0.2 0 0.3 -0.4 10/28/2005 09:40:00 13.9 1 16.1 10.7 14 1.1 16.4 11.1 13 5 7 305 -0.2 0 0.3 -0.4 10/28/2005 09:50:00 13.9 1 15.6 11.5 13.9 1 16.1 11.5 21 6 18 305 -0.3 0 0.3 -0.4 10/28/2005 10:00:00 13.7 1 16.1 10.7 13.9 1.1 16.4 10.7 17 5 28 305 -0.3 0 0.3 -0.4 10/28/2005 10:10:00 13.6 1 15.6 11.1 13.7 1 15.6 10.3 14 5 12 305 -0.4 0 -0.1 -0.6 10/28/2005 10:20:00 13.7 1 16.4 11.5 13.9 1.1 16.8 11.1 16 4 17 305 -0.4 0 0.1 -0.4 10/28/2005 10:30:00 12.8 0.8 14.5 9.9 12.9 0.8 15.3 10.3 12 4 18 305 -0.4 0 -0.4 -0.6 10/28/2005 10:40:00 12.6 1.3 15.6 9.5 12.7 1.4 15.6 9.5 18 5 17 305 -0.4 0 -0.4 -0.6 10/28/2005 10:50:00 13.8 1.1 16.1 9.5 14 1.2 16.4 9.9 17 4 17 305 -0.5 0 -0.4 -0.6 10/28/2005 11:00:00 13.5 0.9 15.6 11.1 13.5 1.1 16.4 9.9 20 6 24 305 -0.5 0 -0.4 -0.6 10/28/2005 11:10:00 13.7 1 16.1 11.1 13.9 1.1 16.8 10.7 19 5 16 305 -0.5 0 0.1 -0.6 10/28/2005 11:20:00 13.9 1.3 17.2 11.1 14.1 1.3 17.6 11.1 17 5 19 305 -0.6 0 -0.6 -0.8 10/28/2005 11:30:00 13.6 0.9 16.1 11.1 13.8 1 16.1 11.1 18 5 16 305 -0.7 0 -0.6 -0.8 10/28/2005 11:40:00 14.1 0.8 16.4 11.8 14.2 1 16.4 11.5 17 5 7 305 -0.7 0 -0.6 -0.8 10/28/2005 11:50:00 14.2 1 16.4 10.7 14.4 1.1 16.4 10.3 11 5 9 305 -0.8 0 -0.6 -1.1 10/28/2005 12:00:00 14 1 16.4 10.7 14.1 1.1 16.4 11.1 14 4 14 305 -0.8 0 -0.6 -1.1 10/28/2005 12:10:00 13.7 1 15.6 10.7 13.8 1 16.1 10.7 22 5 20 305 -0.9 0.1 -0.4 -1.1 10/28/2005 12:20:00 13.9 1.2 16.8 9.9 14.1 1.2 16.8 9.9 18 5 13 305 -0.9 0.1 -0.4 -1.1 10/28/2005 12:30:00 14 0.8 16.1 11.8 14.2 0.9 16.4 11.8 12 3 11 305 -1 0 -0.4 -1.1 10/28/2005 12:40:00 13.5 1 16.4 11.1 13.6 1.1 16.8 10.7 12 5 19 305 -1 0.1 -0.6 -1.1 10/28/2005 12:50:00 12.7 1.1 15.3 9.1 12.9 1.1 15.3 9.1 11 6 11 305 -1.1 0 -0.6 -1.1 10/28/2005 13:00:00 12.7 0.9 14.9 9.5 12.9 1 15.3 9.9 13 6 8 305 -1 0 -0.8 -1.1 10/28/2005 13:10:00 13.2 1.3 17.2 9.5 13.4 1.4 17.2 9.5 13 5 14 305 -1 0.1 -0.6 -1.1 10/28/2005 13:20:00 12.2 1.5 15.6 9.1 12.4 1.5 16.1 9.1 13 5 16 305 -1.1 0 -0.8 -1.3 10/28/2005 13:30:00 12.4 1 14.9 9.9 12.6 1.1 14.9 9.5 16 5 23 305 -1.1 0 -0.6 -1.3 10/28/2005 13:40:00 12.1 1 14.9 8.8 12.2 1.1 14.9 9.5 16 5 10 305 -1.1 0 -0.8 -1.1 10/28/2005 13:50:00 12.8 1.3 15.6 9.5 13 1.4 16.4 9.5 14 4 12 305 -1.1 0 -0.8 -1.3 10/28/2005 14:00:00 12.8 1.1 15.6 10.3 13.1 1.2 16.1 9.9 9 5 12 305 -1.1 0 -0.6 -1.3 10/28/2005 14:10:00 13.5 1 16.4 10.7 13.7 1.1 16.8 9.9 15 5 16 305 -1.1 0 -1.1 -1.3 10/28/2005 14:20:00 13.4 1 16.4 9.9 13.6 1.1 16.4 9.9 13 5 10 305 -1.1 0 -0.6 -1.3 10/28/2005 14:30:00 13.1 1 16.1 10.3 13.3 1.1 16.4 10.3 17 5 12 305 -1.1 0 -0.6 -1.3 10/28/2005 14:40:00 13.5 1.2 17.2 11.1 13.8 1.2 17.6 11.1 13 6 17 305 -1.2 0 -1.1 -1.5 10/28/2005 14:50:00 14.3 1.1 16.8 10.3 14.5 1.2 17.2 10.3 12 5 12 305 -1.2 0 -1.1 -1.3 10/28/2005 15:00:00 13.5 0.9 15.3 10.7 13.6 1 15.6 10.3 14 5 11 305 -1.2 0 -1.1 -1.3 10/28/2005 15:10:00 14.1 0.9 16.4 11.8 14.3 1 16.8 11.1 15 5 16 305 -1.2 0 -1.1 -1.3 10/28/2005 15:20:00 13.9 1 16.4 11.1 14 1 16.8 10.7 12 5 7 305 -1.3 0 -1.1 -1.5 10/28/2005 15:30:00 13.5 1.2 16.4 9.5 13.6 1.3 16.4 8.8 13 4 11 305 -1.2 0 -1.1 -1.3 10/28/2005 15:40:00 13.1 1.3 16.4 10.3 13.2 1.2 16.1 9.9 19 6 22 305 -1.2 0 -1.1 -1.3 10/28/2005 15:50:00 13.7 1 16.1 10.7 13.8 1.1 16.4 10.7 14 5 9 305 -1.1 0 -1.1 -1.3 10/28/2005 16:00:00 13.3 1 15.6 10.3 13.4 1.1 16.1 10.7 16 5 7 305 -1.2 0 -1.1 -1.3 10/28/2005 16:10:00 13.7 1.2 16.8 10.3 13.8 1.2 17.2 10.3 17 5 14 305 -1.1 0 -0.8 -1.3 10/28/2005 16:20:00 12.9 1.2 15.6 9.5 13 1.2 16.1 9.5 14 5 16 305 -1.1 0 -0.8 -1.3 10/28/2005 16:30:00 13.8 0.9 16.1 11.5 13.9 1 16.1 11.5 12 5 12 305 -1.1 0 -1.1 -1.1 10/28/2005 16:40:00 14.1 1 16.4 11.1 14.2 1 16.4 11.8 13 6 22 305 -1.2 0 -1.1 -1.3 10/28/2005 16:50:00 14.3 1.1 16.8 11.5 14.4 1.1 17.6 11.8 13 5 5 305 -1.2 0 -1.1 -1.3 10/28/2005 17:00:00 13.6 1 16.1 10.7 13.8 1.1 16.1 10.3 11 6 13 305 -1.2 0 -0.6 -1.3 10/28/2005 17:10:00 13.3 1.1 16.4 10.3 13.4 1.2 16.4 9.9 15 6 23 305 -1.2 0 -0.6 -1.3 10/28/2005 17:20:00 13.4 1 15.6 10.7 13.6 1.1 16.1 10.7 14 5 12 305 -1.2 0 -0.6 -1.3 10/28/2005 17:30:00 14.3 1.3 17.6 11.5 14.4 1.3 17.6 10.7 11 5 15 305 -1.2 0 -0.6 -1.5 10/28/2005 17:40:00 14 1.3 17.6 11.1 14.1 1.4 17.2 10.7 14 6 17 305 -1.2 0 -0.6 -1.3 10/28/2005 17:50:00 14 0.9 16.1 11.5 14.2 1 16.4 11.5 11 6 15 305 -1.2 0 -0.6 -1.3 10/28/2005 18:00:00 14 1.3 16.8 11.1 14.1 1.4 17.2 10.7 9 4 5 305 -1.2 0 -0.8 -1.3 10/28/2005 18:10:00 14.2 1 16.1 11.5 14.5 1.1 16.8 11.1 9 4 8 305 -1.2 0 -0.6 -1.3 10/28/2005 18:20:00 13.4 1 15.6 9.9 13.7 1.1 16.4 10.3 13 5 18 305 -1.1 0 -1.1 -1.3 10/28/2005 18:30:00 13.8 1.3 17.2 9.9 14 1.3 17.9 9.9 18 6 21 305 -1.2 0 -0.6 -1.3 10/28/2005 18:40:00 14.3 1 16.4 11.5 14.5 1 16.8 11.8 17 5 17 305 -1.1 0 -0.8 -1.3 10/28/2005 18:50:00 12.6 1.3 16.4 9.5 12.8 1.4 16.8 9.5 12 5 9 305 -1.1 0 -0.6 -1.3 10/28/2005 19:00:00 13.4 1.2 16.1 10.3 13.6 1.3 16.4 9.9 10 5 12 305 -1.1 0 -1.1 -1.3 10/28/2005 19:10:00 12.8 0.8 14.5 9.9 13.1 0.8 15.3 9.9 11 5 9 305 -1.1 0 -0.6 -1.3 10/28/2005 19:20:00 13.9 1.3 17.2 10.7 14.1 1.3 17.2 11.1 14 5 10 305 -1 0.1 -0.6 -1.1 10/28/2005 19:30:00 13.9 1.5 16.8 10.3 14.1 1.6 17.6 10.3 11 5 13 305 -1.1 0 -1.1 -1.3 10/28/2005 19:40:00 14.3 1 17.2 12.2 14.5 1 17.2 12.2 9 3 12 305 -1.1 0 -1.1 -1.3 10/28/2005 19:50:00 14 1 16.4 11.5 14.1 1.1 17.2 11.5 14 4 11 305 -1.1 0 -0.8 -1.3 10/28/2005 20:00:00 13.2 1.1 16.4 10.3 13.3 1.2 16.8 10.3 11 6 8 305 -1.1 0 -0.6 -1.3 10/28/2005 20:10:00 13.9 1.1 16.8 10.7 14 1.2 17.2 10.3 14 5 8 305 -1.2 0 -1.1 -1.3 10/28/2005 20:20:00 13.9 1 16.1 11.5 14 1.2 16.4 10.3 16 5 17 305 -1.2 0 -1.1 -1.3 10/28/2005 20:30:00 14.2 1.1 17.2 11.5 14.3 1.1 16.8 10.3 14 5 14 305 -1.2 0 -0.6 -1.3 10/28/2005 20:40:00 13.7 1.1 15.6 10.3 13.9 1.2 17.2 10.7 12 5 8 305 -1.2 0 -1.1 -1.3 10/28/2005 20:50:00 13.8 1.2 17.6 11.1 14 1.3 17.2 9.9 10 5 5 305 -1.2 0 -1.1 -1.3 10/28/2005 21:00:00 14.1 1 16.4 11.1 14.3 1 16.4 11.5 9 3 6 305 -1.3 0 -1.1 -1.5 10/28/2005 21:10:00 14 1.1 16.4 11.1 14.2 1.2 17.2 10.7 9 6 14 305 -1.4 0 -1.1 -1.5 10/28/2005 21:20:00 14.2 1 16.8 11.5 14.5 1.1 17.2 11.8 4 5 6 305 -1.4 0 -1.1 -1.5 10/28/2005 21:30:00 14.7 1.2 17.6 11.1 14.9 1.3 17.9 10.7 5 5 10 305 -1.4 0 -1.1 -1.5 10/28/2005 21:40:00 14.2 1.2 17.6 11.5 14.4 1.2 17.2 11.5 13 8 23 305 -1.4 0 -0.8 -1.5 10/28/2005 21:50:00 14.6 1.3 18.3 11.1 14.7 1.5 18.7 11.1 13 6 10 305 -1.4 0 -0.8 -1.5 10/28/2005 22:00:00 15.1 1.2 17.2 11.5 15.3 1.3 17.9 11.1 7 5 3 305 -1.3 0 -1.1 -1.3 10/28/2005 22:10:00 14.6 1.2 17.6 11.1 14.8 1.3 17.9 10.7 6 4 7 305 -1.5 0 -1.1 -1.8 10/28/2005 22:20:00 14.1 1.1 17.2 11.5 14.1 1.2 17.2 11.1 11 5 8 305 -1.5 0 -1.1 -1.8 10/28/2005 22:30:00 13.9 1.2 16.8 11.5 14 1.2 17.6 10.7 10 6 17 305 -1.4 0 -1.1 -1.8 10/28/2005 22:40:00 13.6 1.4 17.2 10.3 13.8 1.6 17.6 10.3 11 5 8 305 -1.4 0 -1.1 -1.8 10/28/2005 22:50:00 14 1.1 16.4 11.1 14.1 1.2 16.4 11.1 9 8 3 305 -1.4 0.1 -1.1 -1.8 10/28/2005 23:00:00 14.9 1.1 17.6 11.1 15.2 1.1 17.6 12.2 8 4 13 305 -1.6 0 -1.1 -1.8 10/28/2005 23:10:00 14.3 1 16.4 11.8 14.4 1 16.8 11.1 8 5 5 305 -1.5 0 -0.8 -1.5 10/28/2005 23:20:00 13.3 1.1 15.6 9.9 13.5 1.1 16.1 10.3 7 4 8 305 -1.5 0 -1.1 -1.8 10/28/2005 23:30:00 13.4 1.3 16.1 9.5 13.5 1.5 16.8 9.9 7 6 0 305 -1.4 0 -1.1 -1.8 10/28/2005 23:40:00 12.8 1.1 15.3 9.9 13 1.2 15.3 9.5 8 5 19 305 -1.4 0 -1.1 -1.5 10/28/2005 23:50:00 13.5 1.1 16.4 10.7 13.7 1.1 16.4 10.7 10 6 13 305 -1.5 0 -1.1 -1.8 10/29/2005 00:00:00 13.8 1.1 17.2 10.7 14.1 1.2 17.2 10.7 14 5 10 305 -1.5 0 -1.1 -1.8 10/29/2005 00:10:00 12.9 1.1 15.3 8.8 13 1.2 15.6 9.9 11 6 8 305 -1.6 0 -1.3 -1.8 10/29/2005 00:20:00 13.5 1.2 16.8 11.1 13.7 1.2 16.8 11.1 10 5 13 305 -1.6 0 -1.3 -1.8 10/29/2005 00:30:00 13.1 1.5 16.8 8 13.3 1.6 17.2 8.8 5 6 5 305 -1.6 0 -1.3 -1.8 10/29/2005 00:40:00 13.7 1.4 17.2 10.3 13.9 1.4 17.6 10.3 7 5 11 305 -1.5 0 -1.3 -1.8 10/29/2005 00:50:00 13.2 1.2 16.4 10.7 13.5 1.3 16.8 11.1 7 5 359 305 -1.6 0 -1.3 -1.8 10/29/2005 01:00:00 13.8 1.1 15.6 9.9 14.1 1.2 16.1 9.9 6 6 11 305 -1.6 0 -1.3 -1.8 10/29/2005 01:10:00 14.1 1 16.4 11.5 14.3 1 17.2 11.8 9 5 11 305 -1.5 0.1 -1.3 -1.8 10/29/2005 01:20:00 14 1.1 16.8 10.7 14.2 1.1 17.6 11.1 6 4 7 305 -1.5 0 -1.3 -1.8 10/29/2005 01:30:00 13.6 1 16.4 9.9 13.8 1.1 16.8 10.7 8 5 8 305 -1.5 0 -1.3 -1.8 10/29/2005 01:40:00 14 1.2 16.4 11.1 14.2 1.2 17.6 11.1 6 5 4 305 -1.6 0 -1.3 -1.8 10/29/2005 01:50:00 14.2 1.2 17.6 11.1 14.4 1.3 17.9 9.9 4 5 5 305 -1.6 0 -1.3 -1.8 10/29/2005 02:00:00 13.7 1.2 17.6 11.5 13.9 1.2 17.9 10.7 10 6 16 305 -1.6 0 -1.3 -1.8 10/29/2005 02:10:00 13.3 1.1 16.1 10.3 13.5 1.1 16.1 10.3 16 6 6 305 -1.7 0 -1.3 -1.8 10/29/2005 02:20:00 14.1 1.5 17.2 10.7 14.2 1.5 17.6 10.3 15 6 7 305 -1.7 0 -1.3 -2 10/29/2005 02:30:00 14.3 1.3 17.2 10.3 14.4 1.5 17.9 9.5 8 5 7 305 -1.8 0 -1.3 -2 10/29/2005 02:40:00 14.6 1.2 17.2 10.3 14.7 1.3 17.9 10.7 15 5 16 305 -1.8 0 -1.8 -2 10/29/2005 02:50:00 13.6 1.4 17.6 10.7 13.7 1.5 17.2 10.3 17 5 13 305 -1.9 0 -1.8 -2.2 10/29/2005 03:00:00 14 1.1 16.4 10.7 14.1 1.1 16.8 10.7 18 5 22 305 -1.8 0 -1.3 -2 10/29/2005 03:10:00 15.6 1 18.3 12.6 15.7 1.1 18.3 13 18 5 12 305 -1.9 0 -1.5 -2 10/29/2005 03:20:00 13.2 1.3 17.2 10.3 13.3 1.3 17.6 9.9 9 4 8 305 -1.9 0 -1.8 -2 10/29/2005 03:30:00 13.6 1 16.1 10.7 13.8 1.1 16.4 10.7 13 6 9 305 -1.9 0 -1.3 -2 10/29/2005 03:40:00 13.5 1.4 16.8 9.9 13.7 1.5 16.8 10.3 8 5 4 305 -1.9 0 -1.8 -2 10/29/2005 03:50:00 14.3 1.3 17.9 10.3 14.4 1.5 18.7 9.9 7 4 8 305 -1.9 0 -1.8 -2 10/29/2005 04:00:00 13.6 1.4 16.4 10.7 13.8 1.5 16.8 10.7 6 5 8 305 -2 0 -1.8 -2.2 10/29/2005 04:10:00 13.1 1.2 16.1 9.5 13.2 1.2 16.1 9.1 15 6 14 305 -1.8 0 -1.8 -2 10/29/2005 04:20:00 14.1 1 16.4 11.1 14.2 1 16.8 10.7 20 6 26 305 -1.8 0 -1.5 -2 10/29/2005 04:30:00 14.6 1.4 17.9 10.7 14.6 1.5 18.3 10.7 15 6 25 305 -1.8 0 -1.5 -2 10/29/2005 04:40:00 14.7 1.2 18.7 11.1 14.9 1.3 19.1 11.8 15 5 16 305 -1.9 0 -1.8 -2 10/29/2005 04:50:00 13.9 1.3 16.4 9.5 14.1 1.3 16.8 9.9 16 6 15 305 -1.8 0 -1.8 -2 10/29/2005 05:00:00 14.8 1 17.6 11.8 14.9 1.1 17.9 11.8 10 3 8 305 -1.8 0 -1.3 -2 10/29/2005 05:10:00 13.8 1.3 16.8 9.9 14 1.3 17.2 10.3 14 7 26 305 -1.7 0 -1.8 -2 10/29/2005 05:20:00 14.4 1.6 17.9 10.7 14.6 1.6 18.3 11.1 16 4 20 305 -1.7 0 -1.5 -1.8 10/29/2005 05:30:00 14.2 1.3 17.6 10.3 14.4 1.3 17.9 9.9 11 4 12 305 -1.7 0 -1.5 -2 10/29/2005 05:40:00 13.7 1 16.4 11.1 13.9 1 17.2 11.5 15 5 13 305 -1.7 0 -1.8 -2 10/29/2005 05:50:00 13.4 1 16.1 9.9 13.6 1.1 16.1 10.3 16 5 17 305 -1.7 0 -1.5 -1.8 10/29/2005 06:00:00 13.9 1 16.4 11.5 14.1 1 16.8 11.5 16 4 10 305 -1.8 0 -1.8 -2 10/29/2005 06:10:00 12.9 1.5 16.1 9.5 13.1 1.6 16.4 9.1 14 5 18 305 -1.8 0 -1.8 -2 10/29/2005 06:20:00 13.1 1.3 16.1 9.9 13.1 1.4 16.1 9.5 16 6 12 305 -1.8 0 -1.8 -2 10/29/2005 06:30:00 14 1.3 17.2 9.9 14.2 1.3 17.6 10.3 15 5 23 305 -1.8 0 -1.8 -2 10/29/2005 06:40:00 13.5 1.2 16.8 10.7 13.6 1.2 17.6 10.7 9 6 2 305 -1.9 0 -1.8 -2 10/29/2005 06:50:00 13.1 1.1 16.1 10.3 13.4 1.1 16.1 10.3 4 6 12 305 -1.8 0 -1.3 -2 10/29/2005 07:00:00 12.9 1 15.3 10.3 13.1 1.1 15.6 10.7 7 5 6 305 -1.8 0 -1.5 -2 10/29/2005 07:10:00 13 1.2 16.1 9.5 13.2 1.3 15.6 9.1 6 6 9 305 -1.8 0 -1.3 -2 10/29/2005 07:20:00 13.3 1.3 16.1 10.7 13.5 1.3 16.8 9.9 11 4 14 305 -1.8 0 -1.5 -2 10/29/2005 07:30:00 12.7 1.6 16.1 9.1 13 1.7 16.1 9.1 2 5 0 305 -1.8 0 -1.3 -2 10/29/2005 07:40:00 12.8 1.2 15.6 9.9 13.1 1.2 16.1 9.9 2 5 354 305 -1.7 0 -1.3 -1.8 10/29/2005 07:50:00 12.3 1.5 14.9 8.8 12.6 1.5 15.3 8.8 8 4 7 305 -1.7 0 -1.3 -1.8 10/29/2005 08:00:00 12 1.1 14.5 8.8 12.3 1.2 14.9 9.5 10 6 4 305 -1.7 0 -1.3 -2 10/29/2005 08:10:00 11.1 1 13.3 8.4 11.4 1.1 14.1 8.8 6 6 4 305 -1.7 0 -1.3 -1.8 10/29/2005 08:20:00 11.3 1.3 15.6 8.8 11.6 1.2 14.5 8.8 7 8 5 305 -1.7 0 -1.3 -1.8 10/29/2005 08:30:00 11.8 1 13.7 9.1 12.1 0.9 14.1 9.5 10 5 14 305 -1.7 0 -1.3 -1.8 10/29/2005 08:40:00 12.6 1.1 15.3 9.1 12.8 1.2 15.6 9.5 11 5 12 305 -1.7 0 -1.1 -1.8 10/29/2005 08:50:00 11.7 1 14.5 9.1 12 1.1 14.9 9.5 5 6 356 305 -1.7 0 -1.3 -1.8 10/29/2005 09:00:00 11.8 1.2 14.1 7.6 12.1 1.2 14.5 8.4 1 5 4 305 -1.7 0 -1.8 -1.8 10/29/2005 09:10:00 11.3 1.2 14.1 8.8 11.6 1.3 14.9 8 357 5 3 305 -1.7 0 -1.5 -1.8 10/29/2005 09:20:00 11 1.1 13.7 8.4 11.3 1.1 14.1 8.8 359 5 356 305 -1.7 0 -1.5 -2 10/29/2005 09:30:00 10.8 1.3 13.7 8.4 11.2 1.3 14.5 7.6 0 5 357 305 -1.7 0 -1.8 -1.8 10/29/2005 09:40:00 10.8 1.2 13.3 8 11.2 1.3 14.1 8.4 352 6 359 305 -1.8 0 -1.8 -2 10/29/2005 09:50:00 11.3 1.1 13.7 9.1 11.6 1.1 14.5 8.4 2 7 5 305 -1.6 0 -1.3 -1.8 10/29/2005 10:00:00 11.2 1 13.7 8.4 11.5 1.1 14.1 8.8 2 6 1 305 -1.6 0 -1.5 -1.8 10/29/2005 10:10:00 11.2 1.2 13.7 8.4 11.3 1.3 14.1 8.4 7 6 7 305 -1.7 0 -1.5 -1.8 10/29/2005 10:20:00 11.3 1.2 14.9 8.4 11.6 1.2 14.9 8.8 11 6 8 305 -1.6 0 -1.3 -1.8 10/29/2005 10:30:00 10.2 0.9 12.2 8.4 10.5 0.9 12.2 8.4 11 6 13 305 -1.7 0 -1.3 -1.8 10/29/2005 10:40:00 11.1 1.1 13.7 8 11.3 1 13.7 8.4 11 7 11 305 -1.6 0 -1.3 -1.8 10/29/2005 10:50:00 9.6 0.8 11.5 8 9.9 0.8 12.6 7.6 359 6 354 305 -1.6 0 -1.3 -1.8 10/29/2005 11:00:00 10.5 0.9 13 7.6 10.9 0.9 13.7 8.8 359 5 358 305 -1.6 0 -1.3 -1.8 10/29/2005 11:10:00 10.5 1.1 12.6 8 10.9 1.3 13.3 7.6 358 5 353 305 -1.6 0 -1.3 -1.8 10/29/2005 11:20:00 10 1 11.8 8 10.4 1 12.6 8.4 5 4 2 305 -1.6 0 -1.1 -1.8 10/29/2005 11:30:00 9 0.9 12.2 6.5 9.3 1 12.2 6.5 2 8 5 305 -1.5 0 -1.1 -1.8 10/29/2005 11:40:00 11.1 0.8 13.3 9.1 11.5 0.9 13.7 8.8 359 5 351 305 -1.6 0 -1.3 -1.8 10/29/2005 11:50:00 9.7 1.1 12.6 7.2 10.1 1.1 13 7.6 0 7 12 305 -1.6 0.1 -1.3 -1.8 10/29/2005 12:00:00 9.8 1 12.2 6.8 10.2 1 12.6 6.8 3 6 356 305 -1.5 0 -1.1 -1.8 10/29/2005 12:10:00 11.3 1.1 13.7 8.8 11.7 1.2 14.1 8.8 349 5 347 305 -1.9 0.3 -1.3 -2.4 10/29/2005 12:20:00 9.5 0.8 11.5 6.5 9.9 0.9 12.2 7.2 349 5 352 305 -2.1 0.1 -2 -2.4 10/29/2005 12:30:00 9.6 1.6 12.2 5.7 10 1.7 12.6 6.5 358 6 356 305 -2.4 0.3 -1.8 -2.7 10/29/2005 12:40:00 9.6 1 11.5 6.8 10 1 12.2 7.2 6 5 9 305 -2.3 0 -2 -2.4 10/29/2005 12:50:00 9.2 0.7 11.1 7.2 9.6 0.8 11.8 8 2 5 11 305 -2.4 0 -2.2 -2.4 10/29/2005 13:00:00 8.5 1 10.7 6.1 8.8 1 11.1 6.8 0 5 2 305 -2.3 0 -2.2 -2.7 10/29/2005 13:10:00 9.4 1 11.8 6.1 9.8 1.1 12.2 7.2 350 6 345 305 -2.2 0 -2 -2.4 10/29/2005 13:20:00 8.2 0.9 10.7 6.1 8.6 0.9 10.7 6.5 2 10 355 305 -2.1 0.1 -1.8 -2.4 10/29/2005 13:30:00 10.7 1 12.6 8 11.1 1 13 8.4 355 5 352 305 -2.3 0.2 -2 -2.9 10/29/2005 13:40:00 8.7 1 11.1 6.5 9 1.1 11.5 6.5 4 5 5 305 -2.8 0 -2.7 -3.1 10/29/2005 13:50:00 8.2 0.8 9.9 6.1 8.6 0.8 10.3 6.5 1 4 0 305 -2.8 0.1 -2.7 -3.1 10/29/2005 14:00:00 8.8 0.7 10.3 6.8 9.2 0.8 11.1 7.2 355 4 353 305 -2.7 0 -2.4 -2.9 10/29/2005 14:10:00 7.8 0.7 9.5 6.1 8.3 0.8 9.9 6.5 359 4 355 305 -2.8 0 -2.7 -2.9 10/29/2005 14:20:00 7.5 1 9.5 5.3 8 1 10.7 5.7 0 5 1 305 -2.7 0 -2.4 -2.7 10/29/2005 14:30:00 7.5 1.1 10.3 4.9 7.9 1.1 10.7 5.3 4 7 11 305 -2.4 0.1 -2 -2.7 10/29/2005 14:40:00 9.3 0.8 11.5 7.6 9.7 0.8 12.2 7.6 5 7 15 305 -2.2 0 -2 -2.4 10/29/2005 14:50:00 9.6 1 11.8 7.2 9.9 1 12.6 6.8 3 5 0 305 -2.3 0 -2 -2.4 10/29/2005 15:00:00 9.3 0.9 11.8 7.2 9.7 0.9 12.2 7.2 6 7 356 305 -2.2 0.1 -2 -2.4 10/29/2005 15:10:00 9.7 0.9 12.2 7.2 10 1 12.6 7.6 8 6 8 305 -2 0 -1.8 -2 10/29/2005 15:20:00 9.5 1 11.8 7.6 9.9 1 12.6 7.6 1 6 3 305 -1.9 0 -1.8 -2 10/29/2005 15:30:00 8.8 0.8 11.1 6.8 9.1 0.7 11.1 6.8 0 9 14 305 -2 0 -1.8 -2 10/29/2005 15:40:00 8.8 0.9 10.7 6.5 9.2 0.8 10.7 6.5 11 6 18 305 -2.1 0.1 -1.8 -2.2 10/29/2005 15:50:00 8.1 0.8 10.3 5.7 8.5 0.8 10.7 6.5 4 5 4 305 -2.1 0 -1.8 -2.2 10/29/2005 16:00:00 8.6 0.8 11.1 6.8 9 0.8 11.5 6.8 351 11 1 305 -2.1 0 -1.8 -2.2 10/29/2005 16:10:00 9 1 11.1 6.5 9.3 1 11.5 7.2 348 5 348 305 -2.2 0 -1.8 -2.2 10/29/2005 16:20:00 8.1 1.2 10.3 5.3 8.4 1.2 10.7 5.7 357 8 336 305 -2.1 0 -1.8 -2.4 10/29/2005 16:30:00 8.2 1 10.3 5.3 8.6 1 11.1 5.7 357 6 358 305 -2.1 0 -1.8 -2.2 10/29/2005 16:40:00 8.3 1 10.7 6.1 8.6 1.1 11.1 5.7 9 5 14 305 -2 0 -1.8 -2.2 10/29/2005 16:50:00 8.5 0.8 10.7 6.5 8.9 0.9 10.7 6.8 349 9 359 305 -2 0 -1.8 -2 10/29/2005 17:00:00 8.9 1 11.5 6.5 9.3 1 11.8 7.2 345 7 339 305 -2.2 0 -2 -2.4 10/29/2005 17:10:00 9.1 1 11.1 6.1 9.5 1 11.5 6.8 340 4 340 305 -2.5 0.1 -2.2 -2.7 10/29/2005 17:20:00 7.4 1.3 10.7 4.9 7.8 1.3 11.1 5.7 351 5 346 305 -2.7 0 -2.4 -2.7 10/29/2005 17:30:00 8.2 0.6 10.3 6.5 8.5 0.7 10.7 6.8 357 5 355 305 -2.8 0 -2.4 -2.9 10/29/2005 17:40:00 8.7 0.8 10.7 5.7 9 0.9 10.7 6.8 5 5 357 305 -2.8 0.2 -2.4 -3.3 10/29/2005 17:50:00 7.1 1 8.8 4.9 7.5 1 9.1 5.3 354 7 354 305 -3.5 0.2 -3.1 -3.8 10/29/2005 18:00:00 6.8 0.9 8.8 4.6 7.2 1 9.1 4.9 343 7 338 305 -3.5 0 -3.1 -3.8 10/29/2005 18:10:00 5.8 0.6 7.2 4.6 6.4 0.6 8 4.9 340 5 340 305 -3.3 0 -3.1 -3.6 10/29/2005 18:20:00 6.2 0.7 8.4 4.6 6.6 0.7 8.8 4.9 347 12 357 305 -2.9 0 -2.7 -3.1 10/29/2005 18:30:00 6.7 1 9.5 4.2 7.2 0.9 9.9 4.6 353 8 347 305 -2.6 0.1 -2.2 -2.9 10/29/2005 18:40:00 8.2 1 10.7 4.9 8.6 1 10.7 5.3 342 9 333 305 -2.3 0 -2 -2.4 10/29/2005 18:50:00 8.8 0.8 11.5 6.5 9.3 0.8 11.8 7.6 346 10 323 305 -2.5 0 -2.4 -2.7 10/29/2005 19:00:00 9.1 0.6 10.7 7.6 9.5 0.6 10.7 8 350 5 359 305 -2.6 0 -2.4 -2.7 10/29/2005 19:10:00 8.2 0.9 10.3 6.1 8.6 0.9 10.7 6.8 347 4 350 305 -2.8 0 -2.7 -3.1 10/29/2005 19:20:00 8.1 0.9 9.5 4.9 8.5 0.9 10.3 5.7 345 6 347 305 -2.9 0 -2.7 -3.1 10/29/2005 19:30:00 6.9 0.9 9.5 4.2 7.3 0.9 9.9 4.9 345 9 2 305 -2.8 0 -2.4 -3.1 10/29/2005 19:40:00 7.7 0.6 9.5 6.5 8 0.6 9.5 6.5 15 5 16 305 -2.7 0 -2.4 -2.7 10/29/2005 19:50:00 7.7 1.3 10.7 5.3 8.1 1.2 11.5 5.3 2 15 345 305 -2.5 0 -2.2 -2.7 10/29/2005 20:00:00 8.8 0.6 10.7 7.2 9.1 0.7 11.1 6.8 346 8 345 305 -2.2 0 -2 -2.4 10/29/2005 20:10:00 9.6 0.6 11.1 8 9.9 0.6 11.5 7.6 4 4 358 305 -2.3 0 -2 -2.4 10/29/2005 20:20:00 8.5 0.8 10.3 6.8 8.8 0.8 10.7 6.5 4 5 9 305 -2.2 0 -2 -2.4 10/29/2005 20:30:00 8.2 0.7 9.5 6.5 8.6 0.8 10.3 6.5 358 5 356 305 -2.3 0 -2.2 -2.7 10/29/2005 20:40:00 7.3 0.7 8.8 5.3 7.6 0.8 9.1 5.7 4 7 10 305 -2.3 0 -1.8 -2.4 10/29/2005 20:50:00 7.4 0.9 9.1 5.3 7.8 0.9 9.5 5.3 358 6 355 305 -2.2 0 -2 -2.4 10/29/2005 21:00:00 7.3 0.9 9.1 5.3 7.7 0.9 9.9 5.7 2 6 1 305 -2.2 0 -1.8 -2.4 10/29/2005 21:10:00 6.6 0.7 8.8 5.3 7.1 0.6 9.1 5.7 0 6 11 305 -2.2 0 -1.8 -2.4 10/29/2005 21:20:00 6.4 1.1 9.1 3.4 6.8 1.1 9.9 3.8 357 8 353 305 -2.3 0 -1.8 -2.4 10/29/2005 21:30:00 7.6 1 9.5 4.9 7.9 1.1 10.3 5.3 350 7 340 305 -2.4 0.1 -1.8 -2.7 10/29/2005 21:40:00 9.5 0.9 11.5 6.5 9.9 1 11.5 6.8 356 4 350 305 -2.4 0.1 -2 -2.7 10/29/2005 21:50:00 7.9 1.1 10.3 5.3 8.3 1.1 10.7 5.7 2 11 4 305 -3 0.1 -2.7 -3.3 10/29/2005 22:00:00 8.9 1.3 11.5 5.7 9.3 1.3 11.8 6.1 355 8 1 305 -2.7 0.1 -2.4 -2.9 10/29/2005 22:10:00 9.6 0.8 11.8 7.6 10 0.8 11.8 8 356 6 3 305 -2.6 0 -2.4 -2.7 10/29/2005 22:20:00 7.9 1.3 10.3 5.3 8.3 1.3 11.1 5.7 348 4 348 305 -2.7 0 -2.4 -2.9 10/29/2005 22:30:00 7.1 1.8 10.7 4.6 7.5 1.8 11.5 4.9 348 9 4 305 -2.7 0 -2.4 -3.1 10/29/2005 22:40:00 7.9 1 10.3 5.7 8.3 1 10.3 5.7 350 6 353 305 -2.8 0 -2.4 -3.1 10/29/2005 22:50:00 8.4 1.4 10.7 5.3 8.8 1.4 11.1 5.7 9 8 5 305 -3 0.2 -2.7 -3.3 10/29/2005 23:00:00 6 0.8 8.8 4.6 6.4 0.9 9.1 4.6 4 12 350 305 -3 0.2 -2.4 -3.3 10/29/2005 23:10:00 8.1 0.8 9.9 6.1 8.5 0.8 10.7 6.5 344 6 341 305 -2.4 0 -2.2 -2.7 10/29/2005 23:20:00 7.8 0.7 9.5 6.1 8.2 0.7 10.3 6.5 342 5 345 305 -2.4 0 -2.2 -2.7 10/29/2005 23:30:00 6 1 8.8 4.2 6.4 1 9.1 4.6 337 8 329 305 -2.7 0 -2.4 -2.9 10/29/2005 23:40:00 7.2 0.7 8.8 4.9 7.6 0.7 9.1 5.7 346 5 352 305 -2.4 0 -2.2 -2.4 10/29/2005 23:50:00 7.5 0.8 9.5 6.1 8 0.7 9.9 6.1 342 5 350 305 -2.3 0 -2.2 -2.4 10/30/2005 00:00:00 7 0.7 8.8 5.3 7.4 0.7 9.5 5.7 337 8 336 305 -2.4 0 -2.4 -2.7 10/30/2005 00:10:00 6.5 0.9 8.4 4.6 6.9 0.9 8.8 4.6 331 6 327 305 -2.4 0 -2.2 -2.7 10/30/2005 00:20:00 6.8 0.7 8.4 5.3 7.2 0.7 9.1 5.7 343 5 348 305 -2.2 0 -2 -2.4 10/30/2005 00:30:00 8 1.1 10.3 5.3 8.4 1.1 10.3 5.7 345 6 346 305 -2.1 0 -2 -2.2 10/30/2005 00:40:00 8.7 0.7 10.7 6.8 9.1 0.7 11.5 7.2 349 5 350 305 -2.3 0 -2 -2.4 10/30/2005 00:50:00 7.7 0.7 9.5 5.7 8.1 0.8 9.9 6.1 335 6 340 305 -2.4 0 -2.2 -2.7 10/30/2005 01:00:00 6.6 0.7 8.4 4.9 7.1 0.8 8.8 4.9 347 7 350 305 -2.2 0 -1.8 -2.4 10/30/2005 01:10:00 7.1 0.9 9.5 5.3 7.5 0.9 10.3 5.7 343 5 352 305 -2.1 0 -2 -2.2 10/30/2005 01:20:00 7.2 0.7 9.5 5.3 7.5 0.8 9.5 5.7 337 9 337 305 -2.2 0 -2 -2.4 10/30/2005 01:30:00 7.9 0.9 10.7 6.1 8.2 0.9 10.7 6.5 342 5 347 305 -2.1 0 -2 -2.2 10/30/2005 01:40:00 8.6 0.6 10.3 6.5 9.1 0.7 10.7 7.6 349 4 346 305 -2.3 0 -1.8 -2.7 10/30/2005 01:50:00 7.5 0.9 9.1 5.3 7.9 0.9 9.9 5.3 344 6 348 305 -2.7 0 -2.4 -2.7 10/30/2005 02:00:00 7.5 1.1 9.9 4.9 7.9 1.1 10.3 5.3 346 6 345 305 -2.5 0.1 -2.2 -2.7 10/30/2005 02:10:00 7.6 1.1 10.3 4.6 8 1.1 10.7 5.3 338 5 338 305 -2.4 0 -2.2 -2.7 10/30/2005 02:20:00 7.8 1.5 10.3 4.2 8.3 1.5 10.7 4.9 336 8 346 305 -2.7 0.1 -2 -2.9 10/30/2005 02:30:00 6.8 0.8 8.8 3.8 7.1 0.8 9.1 4.9 335 10 350 305 -2.7 0.1 -2.4 -3.1 10/30/2005 02:40:00 6.5 0.8 8.8 4.2 6.9 0.8 8.8 4.6 351 10 337 305 -2.6 0 -2.4 -2.7 10/30/2005 02:50:00 7.5 0.6 9.1 6.1 8 0.6 9.5 6.5 357 4 358 305 -2.4 0 -2.2 -2.4 10/30/2005 03:00:00 7.1 0.9 9.1 5.3 7.5 0.8 9.5 6.1 347 7 359 305 -2.3 0 -1.8 -2.4 10/30/2005 03:10:00 7.4 0.7 9.9 6.1 7.8 0.7 9.9 5.7 353 4 356 305 -2.2 0 -1.8 -2.4 10/30/2005 03:20:00 6.5 0.6 8 5.3 6.9 0.6 8.4 5.3 342 6 343 305 -2.2 0 -1.8 -2.4 10/30/2005 03:30:00 6.4 0.6 8 4.9 6.8 0.6 8.4 5.3 346 5 351 305 -2.2 0 -1.8 -2.4 10/30/2005 03:40:00 6.1 1 8.8 4.2 6.6 1.1 9.1 4.6 344 6 343 305 -2.2 0 -1.8 -2.4 10/30/2005 03:50:00 5.4 0.7 7.6 3.8 5.7 0.7 7.6 4.2 327 10 325 305 -2.2 0 -2 -2.4 10/30/2005 04:00:00 6.3 0.7 8 4.6 6.6 0.7 8.4 4.6 329 10 320 305 -2.2 0 -2 -2.4 10/30/2005 04:10:00 6.3 0.8 8 3.8 6.6 0.8 8 4.2 326 8 332 305 -2.2 0 -2 -2.4 10/30/2005 04:20:00 6.5 0.6 7.6 4.6 6.9 0.7 8.4 4.9 338 6 342 305 -2.2 0 -2 -2.4 10/30/2005 04:30:00 6.4 0.7 8 4.6 6.8 0.7 8.8 4.9 340 8 349 305 -2.2 0 -1.8 -2.4 10/30/2005 04:40:00 5.6 0.8 7.6 3.8 6 0.8 8.4 4.2 347 6 349 305 -2.3 0 -2.2 -2.4 10/30/2005 04:50:00 6 0.9 8 4.2 6.5 0.9 8.4 4.6 343 6 338 305 -2.2 0 -1.8 -2.4 10/30/2005 05:00:00 6.4 0.6 8 4.6 6.7 0.7 8.4 4.9 328 11 326 305 -2.3 0 -2.2 -2.4 10/30/2005 05:10:00 6.1 0.7 8.4 4.2 6.5 0.7 8.8 4.6 332 6 326 305 -2.2 0 -2 -2.4 10/30/2005 05:20:00 5.6 0.8 7.6 4.2 6 0.8 7.6 4.6 343 8 339 305 -2.2 0 -2 -2.4 10/30/2005 05:30:00 6.5 0.6 8.4 4.9 6.8 0.6 8.8 5.3 333 6 325 305 -2.2 0 -1.8 -2.2 10/30/2005 05:40:00 6.1 0.6 8.4 4.6 6.4 0.6 8 4.9 330 6 342 305 -2.2 0 -1.8 -2.2 10/30/2005 05:50:00 6.1 0.8 9.1 4.2 6.5 0.8 9.1 4.6 341 10 323 305 -2.2 0 -2 -2.4 10/30/2005 06:00:00 5.4 0.7 7.2 3.8 5.9 0.8 8 4.2 337 6 339 305 -2.2 0 -2 -2.4 10/30/2005 06:10:00 5.4 0.6 7.2 3.8 5.7 0.6 7.6 4.2 334 12 329 305 -2.2 0 -1.8 -2.4 10/30/2005 06:20:00 5.3 0.8 7.2 3 5.6 0.8 7.6 3.8 331 12 331 305 -2.2 0 -1.8 -2.4 10/30/2005 06:30:00 5.3 0.4 6.5 4.2 5.7 0.4 6.8 4.9 342 5 346 305 -2.2 0 -1.8 -2.2 10/30/2005 06:40:00 5.4 0.5 6.5 4.2 5.8 0.5 6.8 4.2 331 5 314 305 -2.2 0 -2 -2.4 10/30/2005 06:50:00 4.5 0.5 5.7 3 4.9 0.6 6.1 3.4 333 5 331 305 -2.3 0 -2 -2.4 10/30/2005 07:00:00 4.2 0.5 6.1 2.6 4.5 0.6 6.5 3 333 9 342 305 -2.2 0 -2 -2.4 10/30/2005 07:10:00 3.9 0.9 6.8 2.3 4.3 1 6.8 2.6 340 11 330 305 -2.2 0 -1.8 -2.2 10/30/2005 07:20:00 5.6 0.7 7.2 3.8 5.6 0.8 7.2 3.8 309 11 307 305 -2.2 0 -1.8 -2.4 10/30/2005 07:30:00 5.3 0.8 7.2 3.4 5.5 0.7 7.2 3.4 314 12 320 305 -2.2 0 -1.8 -2.4 10/30/2005 07:40:00 5.1 0.5 6.5 3.8 5.3 0.6 7.2 3.8 313 12 326 305 -2.2 0 -2 -2.4 10/30/2005 07:50:00 4.7 0.7 6.1 3.4 4.9 0.7 6.5 3.4 308 5 305 305 -2.2 0 -2 -2.4 10/30/2005 08:00:00 3.1 0.6 4.6 1.9 2.9 0.8 4.6 1.5 289 12 303 305 -2.4 0 -2.2 -2.7 10/30/2005 08:10:00 4.3 0.8 6.5 2.3 4.2 0.9 6.5 2.3 297 13 307 305 -2.3 0 -2.2 -2.4 10/30/2005 08:20:00 3.3 0.7 4.9 1.9 3.5 0.7 4.9 2.3 303 7 301 305 -2.2 0 -2 -2.4 10/30/2005 08:30:00 4.4 0.8 6.5 2.6 4.9 0.8 6.5 3 331 9 310 305 -2.2 0 -2 -2.4 10/30/2005 08:40:00 3.6 0.5 4.9 2.3 3.9 0.5 6.1 2.6 340 12 342 305 -2.2 0 -2 -2.2 10/30/2005 08:50:00 3 0.7 4.9 1.5 3.1 0.6 4.6 1.5 314 13 305 305 -2.2 0 -1.8 -2.4 10/30/2005 09:00:00 3.4 0.7 4.9 1.9 3.8 0.8 5.3 2.3 345 9 338 305 -2.2 0 -2 -2.4 10/30/2005 09:10:00 4 0.6 5.7 3 4.4 0.6 6.1 3 335 9 330 305 -2.1 0 -2 -2.2 10/30/2005 09:20:00 4.3 0.7 6.8 3 4.6 0.7 6.5 3 321 11 320 305 -2.2 0 -2 -2.2 10/30/2005 09:30:00 5.2 0.7 6.8 3.4 5.5 0.8 7.2 3.4 326 8 317 305 -2.1 0 -2 -2.2 10/30/2005 09:40:00 3.5 0.7 5.3 1.9 3.9 0.8 5.7 2.3 333 8 341 305 -2.2 0 -2 -2.2 10/30/2005 09:50:00 3.3 0.5 4.6 1.9 3.7 0.5 4.9 2.6 343 9 344 305 -2.2 0 -2 -2.4 10/30/2005 10:00:00 3.5 0.6 4.9 1.9 3.9 0.6 5.3 2.3 343 7 344 305 -2.2 0 -1.8 -2.4 10/30/2005 10:10:00 4.4 0.8 6.5 2.3 4.6 0.9 6.5 2.3 326 17 315 305 -2.2 0 -2 -2.4 10/30/2005 10:20:00 4.9 0.7 7.2 3.4 5.2 0.7 7.6 3.4 334 11 330 305 -2.2 0 -1.8 -2.4 10/30/2005 10:30:00 5.4 0.6 7.2 4.2 5.8 0.6 7.6 4.2 335 7 331 305 -2.2 0 -2 -2.4 10/30/2005 10:40:00 5.2 0.7 6.8 3.4 5.6 0.7 6.8 3.8 327 7 319 305 -2.2 0 -2 -2.4 10/30/2005 10:50:00 5.1 0.5 6.5 3.8 5.5 0.5 6.8 4.2 327 9 329 305 -2.3 0 -2.2 -2.4 10/30/2005 11:00:00 4.4 0.6 6.1 3 4.8 0.6 6.5 3.4 319 8 327 305 -2.3 0 -2 -2.4 10/30/2005 11:10:00 4.5 0.6 6.1 3 4.6 0.6 6.1 3 310 7 308 305 -2.4 0 -2 -2.7 10/30/2005 11:20:00 4.3 0.6 6.1 3 4.6 0.6 6.5 3.4 319 8 317 305 -2.3 0 -2.2 -2.7 10/30/2005 11:30:00 4.9 0.7 6.8 3.4 5.2 0.6 6.8 3.8 320 8 326 305 -2.3 0 -1.8 -2.4 10/30/2005 11:40:00 4.4 0.6 6.5 3 4.7 0.6 6.5 3 316 8 317 305 -2.3 0 -2.2 -2.4 10/30/2005 11:50:00 3.7 0.6 4.9 2.3 4 0.6 5.3 2.3 319 13 324 305 -2.2 0 -1.8 -2.4 10/30/2005 12:00:00 2.8 0.5 3.8 1.5 3.1 0.4 4.6 1.9 319 13 327 305 -1.9 0 -1.3 -2.2 10/30/2005 12:10:00 3.7 0.9 5.7 1.5 3.9 0.9 5.7 2.3 311 8 317 305 -1.9 0.1 -1.8 -2.2 10/30/2005 12:20:00 4.2 0.5 5.7 3 4.4 0.5 5.7 3 306 7 303 305 -2.1 0 -2 -2.2 10/30/2005 12:30:00 4.1 0.6 5.3 2.6 4.3 0.6 5.7 2.6 317 7 320 305 -2.2 0 -2 -2.2 10/30/2005 12:40:00 3.1 0.9 4.9 1.5 3.1 0.8 4.9 1.5 307 5 319 305 -2.2 0 -2 -2.2 10/30/2005 12:50:00 3.3 0.5 4.6 2.3 3.3 0.4 4.6 2.3 304 12 293 305 -2 0.1 -1.8 -2.2 10/30/2005 13:00:00 2.9 0.8 4.9 1.5 2.8 0.7 4.6 1.5 294 15 299 305 -1.7 0.2 -1.1 -2 10/30/2005 13:10:00 1.8 0.5 3.4 0.4 2.2 0.4 3.4 1.1 318 6 319 305 -1.1 0.1 -0.8 -1.3 10/30/2005 13:20:00 1.8 0.7 3 0.4 2.2 0.6 3.4 0.7 307 8 305 305 -0.6 0.1 -0.4 -1.1 10/30/2005 13:30:00 2.9 0.7 4.6 1.1 3.2 0.7 4.6 1.5 323 12 303 305 -0.7 0 -0.4 -1.1 10/30/2005 13:40:00 3.5 0.4 4.9 2.3 3.8 0.4 5.3 2.6 346 8 352 305 -1.3 0.2 -0.8 -1.8 10/30/2005 13:50:00 3 0.6 4.6 1.5 3.3 0.6 4.6 2.3 347 13 333 305 -1.9 0 -1.5 -2 10/30/2005 14:00:00 3.1 0.6 4.6 1.5 3.3 0.6 4.6 1.9 348 9 334 305 -2 0 -1.8 -2 10/30/2005 14:10:00 3.7 0.4 4.6 3 3.9 0.4 4.9 3 336 8 341 305 -2 0 -2 -2.2 10/30/2005 14:20:00 3.2 0.7 4.9 1.9 3.5 0.7 5.3 2.3 335 10 339 305 -2.1 0 -2 -2.2 10/30/2005 14:30:00 2.7 0.5 4.2 1.5 3 0.5 4.2 1.9 347 6 348 305 -2.1 0 -1.8 -2.2 10/30/2005 14:40:00 2.2 0.5 3 1.1 2.4 0.4 3.4 1.5 342 14 331 305 -1.9 0 -1.3 -2 10/30/2005 14:50:00 2.8 0.6 4.2 1.1 3 0.6 4.2 1.5 343 7 349 305 -1.9 0 -1.8 -2 10/30/2005 15:00:00 2 0.6 3.4 0.7 2.2 0.5 3.8 1.5 344 12 352 305 -1.9 0 -1.3 -2 10/30/2005 15:10:00 1.4 0.6 2.6 0.4 1.8 0.6 3.4 0.4 315 12 299 305 -1.5 0.1 -1.1 -1.8 10/30/2005 15:20:00 0.4 0.1 1.1 0.4 0.7 0.3 1.1 0.4 343 2 344 305 -1.2 0.3 -0.1 -1.8 10/30/2005 15:30:00 0.5 0.3 1.5 0.4 0.7 0.5 1.9 0.4 352 19 3 305 -0.8 0.3 0.1 -1.3 10/30/2005 15:40:00 0.9 0.5 1.9 0.4 1.5 0.4 2.3 0.7 345 13 337 305 -1.5 0.1 -1.1 -1.8 10/30/2005 15:50:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 322 56 305 305 -0.7 0.4 0.1 -1.5 10/30/2005 16:00:00 0.4 0.1 1.1 0.4 0.8 0.3 1.5 0.4 145 11 124 305 0.3 0.2 0.8 -0.4 10/30/2005 16:10:00 1 0.4 1.9 0.4 1.4 0.3 1.9 0.7 124 10 124 305 -0.2 0.4 0.8 -0.8 10/30/2005 16:20:00 1.2 0.4 2.3 0.4 1.5 0.3 2.3 0.7 107 6 113 305 -0.7 0.1 0.1 -1.1 10/30/2005 16:30:00 1.1 0.2 1.5 0.7 1.4 0.2 1.9 1.1 111 1 112 305 -0.3 0.1 0.3 -0.4 10/30/2005 16:40:00 1 0.3 1.9 0.4 1.3 0.3 1.9 0.7 93 11 83 305 -0.6 0 0.1 -0.8 10/30/2005 16:50:00 0.5 0.2 1.1 0.4 0.8 0.3 1.5 0.4 83 0 83 305 -1 0.2 -0.6 -1.5 10/30/2005 17:00:00 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 83 0 83 305 -2.1 0.3 -1.1 -2.7 10/30/2005 17:10:00 0.4 0.1 0.7 0.4 0.7 0.3 1.1 0.4 97 13 83 305 -3 0.1 -2.2 -3.3 10/30/2005 17:20:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 108 0 305 305 -3.2 0.1 -3.1 -3.8 10/30/2005 17:30:00 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 108 0 305 305 -4 0.2 -3.3 -4.5 10/30/2005 17:40:00 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 108 0 108 305 -4.3 0 -3.8 -4.5 10/30/2005 17:50:00 0.7 0.3 1.5 0.4 1.1 0.2 1.5 0.7 108 0 108 305 -4.6 0.2 -4.2 -4.9 10/30/2005 18:00:00 0.9 0.2 1.1 0.4 1.4 0.2 1.9 1.1 118 8 108 305 -4.9 0.1 -4.7 -5.1 10/30/2005 18:10:00 1 0.2 1.5 0.4 1.4 0.2 1.9 0.7 125 0 125 305 -4.1 0.3 -3.8 -4.7 10/30/2005 18:20:00 1.5 0.1 1.9 1.1 1.7 0.2 1.9 1.5 126 2 125 305 -4 0 -3.8 -4.2 10/30/2005 18:30:00 2.1 0.3 2.6 1.5 2.2 0.2 2.6 1.5 133 0 133 305 -4 0 -3.8 -4 10/30/2005 18:40:00 2.5 0.2 3 2.3 2.6 0.2 3 2.3 134 2 134 305 -4 0 -3.8 -4 10/30/2005 18:50:00 2.9 0.3 3.4 2.3 3 0.3 3.4 2.3 142 1 143 305 -4 0 -3.8 -4.2 10/30/2005 19:00:00 3.5 0.2 3.8 3 3.5 0.1 3.8 3 145 1 145 305 -4.2 0 -4 -4.2 10/30/2005 19:10:00 3.7 0.2 4.2 3.4 3.9 0.2 4.2 3.4 146 1 145 305 -4.3 0 -3.8 -4.5 10/30/2005 19:20:00 4 0.3 4.6 3.4 4.1 0.4 4.9 3.4 149 2 150 305 -4.5 0 -4.5 -4.7 10/30/2005 19:30:00 4.5 0.2 4.9 4.2 4.5 0.2 4.9 3.8 142 2 145 305 -4.6 0.1 -4.5 -4.9 10/30/2005 19:40:00 5 0.2 5.3 4.2 4.9 0.3 5.7 4.2 138 3 137 305 -4.2 0.1 -3.8 -4.5 10/30/2005 19:50:00 5.4 0.2 5.7 4.9 5.4 0.2 5.7 4.9 136 1 141 305 -4.2 0 -4 -4.5 10/30/2005 20:00:00 5.5 0.2 5.7 4.9 5.6 0.2 6.1 4.9 136 2 132 305 -4 0 -3.6 -4.2 10/30/2005 20:10:00 5.3 0.4 5.7 4.2 5.3 0.4 6.1 3.8 129 5 136 305 -3.9 0.3 -3.3 -4.2 10/30/2005 20:20:00 4.7 0.4 5.7 3.4 4.8 0.4 5.7 3.8 125 5 127 305 -3.2 0 -3.1 -3.3 10/30/2005 20:30:00 5.1 0.6 6.5 3.4 5.1 0.5 6.5 3.8 127 7 133 305 -3.2 0 -3.1 -3.3 10/30/2005 20:40:00 5.6 0.5 6.5 4.2 5.5 0.5 6.8 4.2 130 5 130 305 -3.2 0 -3.1 -3.3 10/30/2005 20:50:00 5.3 0.6 7.2 3.8 5.2 0.6 6.8 3.8 131 6 131 305 -3 0 -2.9 -3.1 10/30/2005 21:00:00 5.4 0.3 6.1 4.2 5.1 0.4 5.7 3.8 135 3 134 305 -3.6 0.3 -2.9 -4 10/30/2005 21:10:00 5.5 0.5 6.5 3.8 5.4 0.5 6.5 3.8 134 5 123 305 -3.5 0.1 -3.3 -3.8 10/30/2005 21:20:00 5.9 0.4 6.8 4.6 5.6 0.4 6.5 4.6 137 3 133 305 -3.7 0.1 -3.3 -4 10/30/2005 21:30:00 6.2 0.6 7.6 4.2 6.1 0.6 7.6 4.2 133 5 132 305 -3.5 0.3 -3.1 -4 10/30/2005 21:40:00 6.8 0.5 8.4 5.3 6.6 0.5 8 5.3 134 5 142 305 -2.8 0 -2.7 -3.1 10/30/2005 21:50:00 7.6 0.4 8.8 6.5 7.4 0.5 8.8 6.1 136 3 137 305 -2.7 0.1 -2.4 -3.1 10/30/2005 22:00:00 7.5 0.7 9.5 5.7 7.2 0.7 9.5 5.7 140 6 142 305 -2.4 0 -1.8 -2.7 10/30/2005 22:10:00 7.3 0.7 9.5 4.9 7.3 0.7 9.1 5.3 140 8 150 305 -2.2 0 -2 -2.4 10/30/2005 22:20:00 8.1 0.6 9.5 6.1 8.1 0.6 9.5 6.5 135 5 139 305 -2 0 -1.5 -2.2 10/30/2005 22:30:00 8 0.6 9.1 6.5 7.8 0.5 9.1 6.1 134 5 135 305 -2 0 -2 -2 10/30/2005 22:40:00 7.9 0.6 9.5 6.1 7.8 0.6 9.5 6.1 133 4 136 305 -2 0 -1.8 -2 10/30/2005 22:50:00 8.1 0.5 9.1 6.5 8 0.6 9.1 6.1 131 4 131 305 -1.9 0 -1.8 -2 10/30/2005 23:00:00 8.3 0.7 10.3 6.1 8.2 0.8 9.9 5.3 129 6 125 305 -1.9 0 -1.8 -2 10/30/2005 23:10:00 7.4 1.2 10.7 4.6 7.5 1.1 10.7 4.6 125 11 108 305 -1.9 0 -1.8 -2 10/30/2005 23:20:00 8.4 1.1 12.2 5.3 8.4 1 11.8 5.7 132 9 140 305 -1.9 0 -1.8 -2 10/30/2005 23:30:00 8.7 1.4 11.5 4.6 8.6 1.4 11.5 4.2 131 10 139 305 -1.9 0 -1.8 -2 10/30/2005 23:40:00 8.1 1.2 11.5 5.7 8 1.2 11.1 5.3 131 11 141 305 -1.9 0 -1.5 -2 10/30/2005 23:50:00 8.2 1.3 11.1 4.6 7.9 1.3 11.1 4.6 134 11 147 305 -1.9 0 -1.3 -2 10/31/2005 00:00:00 9.3 1 11.5 6.8 9.1 1.1 11.5 6.5 132 6 135 305 -1.7 0 -1.3 -1.8 10/31/2005 00:10:00 10.2 1.2 12.6 6.8 9.9 1.1 12.2 6.5 134 7 134 305 -1.6 0 -1.1 -1.8 10/31/2005 00:20:00 10.9 0.7 12.6 7.6 10.7 0.7 12.2 8.4 136 5 136 305 -1.6 0 -1.3 -1.8 10/31/2005 00:30:00 10.7 1 12.6 6.8 10.5 0.9 12.6 7.2 132 6 136 305 -1.6 0 -1.3 -1.8 10/31/2005 00:40:00 11 0.7 12.6 8.4 10.8 0.8 12.6 8.8 133 4 134 305 -1.7 0 -1.5 -1.8 10/31/2005 00:50:00 10 1 12.6 7.2 9.9 1.1 12.6 6.8 132 7 132 305 -1.6 0 -1.1 -1.8 10/31/2005 01:00:00 10.7 1.2 13.7 6.8 10.4 1.2 13.3 6.8 135 6 134 305 -1.5 0 -1.3 -1.8 10/31/2005 01:10:00 11.5 0.9 13.3 8.8 11.2 1 13.3 8 135 5 137 305 -1.4 0 -1.3 -1.5 10/31/2005 01:20:00 11.4 0.8 13 9.1 11.3 0.8 13.3 8.8 134 5 135 305 -1.6 0 -1.1 -1.8 10/31/2005 01:30:00 11.7 0.8 13.7 9.5 11.6 0.9 13.3 9.1 132 5 122 305 -1.6 0 -1.1 -1.8 10/31/2005 01:40:00 11.1 1 13 7.2 11 1 13 7.6 131 6 132 305 -1.6 0 -1.3 -1.8 10/31/2005 01:50:00 10.1 1.1 13 6.5 9.9 1.2 14.1 5.7 131 8 138 305 -1.5 0 -1.3 -1.8 10/31/2005 02:00:00 9.6 1.3 13.3 5.3 9.4 1.4 14.5 4.9 132 10 145 305 -1.4 0 -1.1 -1.5 10/31/2005 02:10:00 10.2 1.4 13 6.1 9.8 1.5 12.6 5.7 134 7 128 305 -1.2 0 -1.1 -1.3 10/31/2005 02:20:00 10.6 1.1 13.7 7.6 10.4 1.1 13 7.2 136 7 141 305 -1.1 0 -1.1 -1.3 10/31/2005 02:30:00 11.1 1.3 13.7 6.8 11.1 1.3 14.5 7.2 137 7 128 305 -1 0 -0.8 -1.1 10/31/2005 02:40:00 11.7 1.3 14.9 8.4 11.5 1.4 14.5 8 137 7 131 305 -0.8 0 -0.6 -1.1 10/31/2005 02:50:00 12 1.1 14.5 8 12 1.1 14.5 8.8 136 6 138 305 -0.9 0 -0.6 -1.1 10/31/2005 03:00:00 12.9 1.1 16.1 9.5 12.8 1.1 15.6 9.5 135 5 141 305 -1 0 -0.6 -1.1 10/31/2005 03:10:00 12.4 1.2 14.9 9.5 12.2 1.2 14.9 9.5 133 5 132 305 -1.1 0 -0.8 -1.3 10/31/2005 03:20:00 12.3 1.1 15.3 9.5 12.1 1.1 15.6 9.1 133 6 142 305 -1.2 0 -1.1 -1.3 10/31/2005 03:30:00 12.9 1.1 14.9 9.1 12.7 1.1 14.9 9.1 133 6 138 305 -1.2 0 -1.1 -1.3 10/31/2005 03:40:00 13.1 1.2 15.6 9.1 12.9 1.2 15.6 8.8 133 6 130 305 -1.2 0 -1.1 -1.3 10/31/2005 03:50:00 13 1.2 15.6 9.5 12.8 1.3 15.3 9.5 134 5 137 305 -1.1 0 -1.1 -1.3 10/31/2005 04:00:00 13.3 1.1 16.1 9.1 13 1 16.1 9.9 134 6 128 305 -1.1 0 -1.1 -1.3 10/31/2005 04:10:00 13.1 1 16.1 9.5 13 1 15.3 9.9 134 5 138 305 -1.1 0 -1.1 -1.3 10/31/2005 04:20:00 12.4 1.1 16.1 9.1 12.2 1.1 14.9 9.1 132 7 129 305 -1.1 0 -1.1 -1.3 10/31/2005 04:30:00 11.3 1.7 16.1 5.7 11.2 1.7 16.1 5.7 132 11 152 305 -1.2 0 -1.1 -1.3 10/31/2005 04:40:00 12.7 1.4 16.4 8.4 12.5 1.4 17.6 8.4 134 8 135 305 -1.2 0 -0.8 -1.3 10/31/2005 04:50:00 13.4 1.2 15.6 9.5 13.1 1.3 15.6 9.1 134 5 134 305 -1.2 0 -1.1 -1.3 10/31/2005 05:00:00 12.8 1.1 16.1 10.3 12.5 1.2 16.1 9.5 134 6 136 305 -1.2 0 -0.8 -1.3 10/31/2005 05:10:00 13.6 1.5 16.1 9.1 13.3 1.5 16.1 9.5 134 5 138 305 -1.1 0 -0.6 -1.1 10/31/2005 05:20:00 14.8 1.1 17.2 11.1 14.4 1.2 16.8 11.5 135 5 138 305 -1 0 -0.6 -1.1 10/31/2005 05:30:00 14.3 1.5 17.9 9.5 14.1 1.4 17.6 9.5 136 5 135 305 -1 0 -0.6 -1.1 10/31/2005 05:40:00 14 1.4 17.2 9.5 13.8 1.3 16.4 9.9 135 5 140 305 -0.8 0 -0.4 -1.1 10/31/2005 05:50:00 14.8 1.3 17.9 10.3 14.6 1.3 17.6 10.3 136 5 134 305 -0.8 0 -0.4 -1.1 10/31/2005 06:00:00 13.8 1.2 16.4 9.5 13.5 1.1 16.4 10.3 134 5 135 305 -0.8 0 -0.6 -0.8 10/31/2005 06:10:00 14.2 1.2 17.2 10.7 14 1.2 16.8 10.7 135 5 140 305 -0.7 0 -0.4 -0.8 10/31/2005 06:20:00 14.1 1.2 17.2 10.3 13.8 1.2 17.6 10.7 133 5 135 305 -0.7 0 -0.1 -0.8 10/31/2005 06:30:00 14 1.3 16.8 10.3 13.8 1.2 16.4 10.7 134 6 129 305 -0.6 0 -0.4 -0.6 10/31/2005 06:40:00 14.4 1.1 16.8 11.5 14.1 1 16.4 11.1 134 5 137 305 -0.6 0 -0.4 -0.6 10/31/2005 06:50:00 14.2 1.1 16.8 11.5 14.1 1.1 16.4 11.5 133 5 131 305 -0.5 0 0.1 -0.6 10/31/2005 07:00:00 13.5 1.1 16.4 10.7 13.3 1.1 16.1 10.3 133 5 134 305 -0.5 0 0.1 -0.6 10/31/2005 07:10:00 13.1 1.3 16.4 9.1 13 1.2 16.8 8.8 132 7 142 305 -0.3 0 -0.1 -0.4 10/31/2005 07:20:00 13.3 1.4 17.2 10.3 12.9 1.4 16.4 9.5 134 7 137 305 -0.2 0 0.1 -0.4 10/31/2005 07:30:00 12.4 1.5 15.6 8 12.3 1.6 15.6 6.8 133 7 135 305 -0.1 0 0.1 -0.4 10/31/2005 07:40:00 13.3 1.5 16.8 9.1 13.1 1.4 16.8 9.1 134 7 137 305 0.1 0.1 0.3 -0.1 10/31/2005 07:50:00 14.2 1.3 17.6 9.9 13.9 1.3 17.6 9.9 136 7 136 305 0.3 0 0.6 0.1 10/31/2005 08:00:00 14.4 1.5 17.9 8.4 14.1 1.5 17.9 9.1 135 7 130 305 0.4 0 0.6 0.3 10/31/2005 08:10:00 13.4 1.6 17.6 9.1 13.1 1.6 17.6 8.8 136 8 130 305 0.4 0 0.6 0.3 10/31/2005 08:20:00 13.6 1.6 17.2 9.9 13.5 1.6 17.2 9.5 136 8 143 305 0.5 0 0.6 0.3 10/31/2005 08:30:00 14.2 1.7 17.9 8.8 14 1.6 19.1 9.1 136 6 134 305 0.5 0 0.6 0.3 10/31/2005 08:40:00 13.8 1.5 19.1 9.1 13.6 1.6 19.1 9.5 135 6 143 305 0.4 0 0.8 0.3 10/31/2005 08:50:00 13.6 1.7 17.9 8.8 13.4 1.7 17.6 9.1 135 6 138 305 0.5 0 1 0.3 10/31/2005 09:00:00 14.4 1.3 17.2 9.9 14.1 1.4 17.9 9.9 135 6 135 305 0.5 0 1 0.6 10/31/2005 09:10:00 14.2 1.3 17.9 9.9 13.9 1.4 17.6 10.7 134 7 128 305 0.6 0 1 0.6 10/31/2005 09:20:00 13.9 1.6 17.2 9.9 13.7 1.7 17.6 9.5 135 7 135 305 0.7 0 1.3 0.6 10/31/2005 09:30:00 14.3 1.6 18.3 9.9 14.2 1.6 18.3 9.9 135 7 133 305 0.8 0 1.3 0.6 10/31/2005 09:40:00 15.2 1.5 19.1 11.5 15 1.4 19.5 11.8 133 6 140 305 0.9 0 1.3 0.8 10/31/2005 09:50:00 15 1.4 18.7 10.7 14.8 1.3 19.1 10.7 134 6 129 305 0.9 0 1 0.8 10/31/2005 10:00:00 14.9 1.5 19.1 9.9 14.7 1.5 18.3 11.1 135 7 136 305 1 0 1.5 0.8 10/31/2005 10:10:00 14.4 1.6 18.3 9.9 14.3 1.7 18.3 9.9 135 7 139 305 1 0.8 14.8 0.8 10/31/2005 10:20:00 14.5 1.5 17.9 9.9 14.1 1.5 18.7 10.3 135 7 132 305 1 0 1.5 1 10/31/2005 10:30:00 14.5 1.5 18.3 10.7 14.4 1.6 18.3 10.3 135 7 142 305 1 0 1.5 0.8 10/31/2005 10:40:00 14.7 1.5 18.3 10.7 14.6 1.4 17.9 10.3 135 7 144 305 1 0 1.5 1 10/31/2005 10:50:00 14.7 1.7 19.5 11.1 14.5 1.5 19.9 9.5 141 9 151 305 1 0 1.3 1 10/31/2005 11:00:00 15.1 1.5 19.1 10.3 14.9 1.6 19.1 10.3 133 7 135 305 1 0 1.5 1 10/31/2005 11:10:00 15.3 1.6 18.7 9.9 15.1 1.7 19.9 8.8 133 7 132 305 1 0 1.5 1 10/31/2005 11:20:00 14.9 1.7 19.1 9.1 14.7 1.7 19.1 9.5 137 8 142 305 1.1 0 1.5 1 10/31/2005 11:30:00 15.2 1.6 18.7 10.7 15 1.7 19.1 9.9 136 9 129 305 1 0 1.3 1 10/31/2005 11:40:00 14.6 2 19.5 9.1 14.5 2 19.5 9.5 137 8 148 305 1.1 0 1.3 1 10/31/2005 11:50:00 14.9 2 19.5 9.9 14.8 2.1 19.5 9.5 134 8 119 305 1.1 0 1.5 1 10/31/2005 12:00:00 15 1.8 19.5 9.1 15 1.8 19.5 9.9 135 9 130 305 1.1 0 1.5 1 10/31/2005 12:10:00 15.3 1.5 19.5 10.7 15 1.5 19.1 11.1 134 6 137 305 1 0 1.5 1 10/31/2005 12:20:00 15.9 1.5 20.2 11.5 15.6 1.6 20.6 10.7 134 7 132 305 1 0 1.5 1 10/31/2005 12:30:00 16.2 1.5 20.2 12.2 15.9 1.6 20.2 10.7 134 6 129 305 1 0 1.3 1 10/31/2005 12:40:00 15.6 1.6 19.5 11.5 15.3 1.6 19.5 11.5 133 7 129 305 1 0 1.5 1 10/31/2005 12:50:00 15.9 1.3 20.6 11.8 15.6 1.5 20.2 11.8 134 6 126 305 1 0 1.5 1 10/31/2005 13:00:00 16 1.7 19.9 10.7 15.7 1.7 19.9 11.1 134 7 140 305 1.1 0 1.3 1 10/31/2005 13:10:00 16.4 1.5 20.6 11.5 16.1 1.7 20.2 11.1 134 5 138 305 1 0 1.5 1 10/31/2005 13:20:00 16.4 1.5 20.2 12.2 16.1 1.7 19.9 11.1 134 6 127 305 1.1 0 1.5 1 10/31/2005 13:30:00 15.6 1.7 19.5 10.7 15.3 1.7 20.6 10.7 133 7 137 305 1.1 0 1.5 1 10/31/2005 13:40:00 15.7 1.6 19.1 11.1 15.5 1.6 19.5 11.1 134 6 124 305 1 0 1.5 1 10/31/2005 13:50:00 15.4 1.7 19.1 11.1 15.1 1.7 18.3 10.7 135 8 141 305 1 0 1.5 1 10/31/2005 14:00:00 15.8 1.7 19.9 11.1 15.5 1.7 19.5 10.3 134 7 127 305 1 0 1.5 1 10/31/2005 14:10:00 15.7 1.9 19.5 10.7 15.6 1.9 21.8 9.9 134 8 134 305 1 0 1.5 1 10/31/2005 14:20:00 14.4 2 19.1 7.6 14.3 2 19.5 8.8 134 9 142 305 1 0 1.5 1 10/31/2005 14:30:00 14.5 2.1 20.2 9.5 14.3 2.1 19.9 9.1 134 9 130 305 1 0 1.5 1 10/31/2005 14:40:00 13.8 2.2 20.6 8.4 13.5 2.1 19.9 7.6 134 11 145 305 1 0 1.5 1 10/31/2005 14:50:00 14.2 1.9 20.2 9.9 14.3 2.1 21.8 9.1 136 10 144 305 1 0 1.5 1 10/31/2005 15:00:00 13 2.9 20.2 5.3 13 2.8 20.2 6.5 136 15 128 305 1 0 1.5 0.8 10/31/2005 15:10:00 14.6 2.3 21.4 9.5 14.5 2.2 22.1 9.1 134 11 133 305 1 0 1.5 0.8 10/31/2005 15:20:00 13.6 2.3 19.1 7.6 13.4 2.4 18.7 5.3 132 13 125 305 1 0 1.5 0.8 10/31/2005 15:30:00 14 2.4 20.6 7.2 13.9 2.5 21 6.5 132 12 109 305 1 0 1.5 0.8 10/31/2005 15:40:00 13.5 2.3 20.2 6.8 13.2 2.2 20.6 8 134 13 140 305 1 0 1 0.8 10/31/2005 15:50:00 12.8 2.5 21 5.7 12.8 2.4 20.2 6.5 132 15 124 305 0.9 0 1.3 0.8 10/31/2005 16:00:00 12 2.5 19.5 5.3 11.9 2.4 17.9 6.1 131 14 137 305 0.9 0 1 0.8 10/31/2005 16:10:00 12.7 2.8 19.5 4.6 12.3 2.9 19.5 5.3 129 15 140 305 0.9 0 1 0.8 10/31/2005 16:20:00 12.7 2.6 21 6.1 12.5 2.8 20.6 5.7 125 16 118 305 0.8 0 1.3 0.6 10/31/2005 16:30:00 11.4 2.3 17.6 5.7 11.3 2.2 16.8 4.9 125 17 111 305 0.8 0 1.3 0.6 10/31/2005 16:40:00 12.4 2.9 19.9 4.6 12.1 2.9 19.9 4.6 126 16 141 305 0.8 0 1 0.6 10/31/2005 16:50:00 11.8 2.9 19.5 4.9 11.6 2.8 19.1 5.3 122 18 94 305 0.8 0 1.3 0.6 10/31/2005 17:00:00 13.1 2.7 22.6 6.5 12.8 2.8 20.6 4.9 123 15 120 305 0.7 0 1.3 0.6 10/31/2005 17:10:00 12.5 2.6 19.9 6.1 12.2 2.7 19.1 7.6 123 14 120 305 0.7 0 0.8 0.6 10/31/2005 17:20:00 12.6 2.8 19.9 5.7 12.3 2.6 20.2 6.1 125 15 120 305 0.6 0 1 0.6 10/31/2005 17:30:00 11.6 2.6 17.9 4.9 11.3 2.6 17.9 4.9 122 19 108 305 0.5 0 0.6 0.6 10/31/2005 17:40:00 12.3 2.9 20.2 4.9 12.1 2.9 21.4 4.6 124 17 129 305 0.5 0 0.8 0.6 10/31/2005 17:50:00 12.4 3.1 20.6 4.6 12.1 2.8 19.1 6.1 125 16 117 305 0.5 0 1 0.6 10/31/2005 18:00:00 12.6 3.1 19.9 4.9 12.2 3.1 20.2 6.1 123 15 114 305 0.5 0 1 0.3 10/31/2005 18:10:00 12 2.9 18.7 5.3 12 2.9 19.1 4.6 124 16 119 305 0.4 0 1 0.3 10/31/2005 18:20:00 12.8 2.7 20.2 7.2 12.6 2.7 19.9 7.2 123 16 124 305 0.4 0 1 0.3 10/31/2005 18:30:00 12.4 2.7 20.6 7.2 12.4 2.7 19.9 6.1 123 16 127 305 0.4 0 1 0.3 10/31/2005 18:40:00 12.4 2.9 21 6.5 12.3 2.8 21 6.1 122 17 122 305 0.3 0 0.8 0.1 10/31/2005 18:50:00 12.9 2.7 21.4 6.5 12.7 2.8 19.9 6.5 121 15 119 305 0.3 0 0.8 0.1 10/31/2005 19:00:00 13.1 2.5 20.6 7.6 12.9 2.5 21 8 124 16 123 305 0.2 0 0.8 0.1 10/31/2005 19:10:00 12.3 2.2 18.7 7.6 12.3 2.1 18.3 6.8 124 15 134 305 0.2 0 0.6 0.1 10/31/2005 19:20:00 12.8 2.6 20.2 6.8 12.5 2.6 20.2 6.8 125 15 107 305 0.2 0.1 0.6 0.1 10/31/2005 19:30:00 12.8 2.6 20.2 6.1 12.7 2.5 21.4 6.5 127 14 140 305 0.2 0.1 0.6 0.1 10/31/2005 19:40:00 12.7 2.9 24.4 6.5 12.4 3.1 23.7 6.1 128 17 123 305 0.1 0.1 0.6 0.1 10/31/2005 19:50:00 12 2.6 20.2 6.5 12 2.7 19.9 6.1 121 15 118 305 0.2 0.1 0.6 0.1 10/31/2005 20:00:00 11.5 2.6 18.3 6.1 11.3 2.5 16.8 6.1 123 15 137 305 0.1 0 0.6 0.1 10/31/2005 20:10:00 13.1 2.6 18.7 7.2 12.7 2.6 21 7.2 124 17 127 305 0.1 0 0.6 0.1 10/31/2005 20:20:00 13.6 2.7 21.4 7.2 13.5 2.9 21 7.6 127 14 121 305 0 0 0.3 0.1 10/31/2005 20:30:00 13.3 2.7 21.4 6.5 13 2.6 20.6 7.2 119 17 127 305 -0.1 0 0.3 -0.4 10/31/2005 20:40:00 12.3 2.8 20.2 6.1 12.1 2.6 19.5 7.2 121 15 137 305 -0.1 0 0.3 -0.4 10/31/2005 20:50:00 12.9 2.7 21.4 6.1 12.5 2.6 21 6.8 124 15 119 305 -0.3 0 0.1 -0.4 10/31/2005 21:00:00 12.8 3.5 22.9 4.2 12.4 3.5 24.8 4.9 123 17 92 305 -0.3 0 0.1 -0.4 10/31/2005 21:10:00 13.3 3.1 21.8 6.8 12.9 2.9 21.8 4.9 119 17 111 305 -0.4 0 0.1 -0.4 10/31/2005 21:20:00 14 2.8 20.2 8 13.7 2.9 20.2 7.6 121 15 133 305 -0.4 0 0.1 -0.4 10/31/2005 21:30:00 13.9 3.1 22.1 7.2 13.7 3.1 21.8 7.2 127 13 129 305 -0.4 0 0.1 -0.6 10/31/2005 21:40:00 11.8 2.7 19.5 6.1 11.6 2.5 19.1 5.7 122 17 119 305 -0.4 0 0.1 -0.4 10/31/2005 21:50:00 13.1 2.5 19.5 6.8 12.6 2.4 19.9 7.2 115 15 123 305 -0.4 0.1 0.1 -0.6 10/31/2005 22:00:00 12.4 3.1 21.4 6.1 12.4 3.2 21.8 7.2 120 17 143 305 -0.5 0.1 0.1 -0.6 10/31/2005 22:10:00 12.5 2.8 20.2 5.3 12.2 2.7 19.9 5.7 118 17 128 305 -0.5 0 -0.1 -0.6 10/31/2005 22:20:00 11.5 2.7 19.5 5.3 11.2 2.5 18.3 6.1 117 17 118 305 -0.5 0 0.1 -0.6 10/31/2005 22:30:00 12.6 3.1 21.4 5.3 12.3 2.8 20.2 5.3 121 16 146 305 -0.5 0 0.1 -0.6 10/31/2005 22:40:00 11.9 2.7 21.8 5.3 11.5 2.7 19.5 6.1 117 17 139 305 -0.5 0 0.1 -0.6 10/31/2005 22:50:00 12 2.9 21 4.9 11.7 2.8 21.4 4.6 122 17 108 305 -0.5 0 -0.1 -0.6 10/31/2005 23:00:00 12 2.7 21.8 6.1 11.4 2.7 20.6 3.8 122 20 134 305 -0.5 0 0.1 -0.6 10/31/2005 23:10:00 10.9 2.9 19.9 4.9 10.5 2.7 18.7 4.9 121 18 140 305 -0.5 0 0.1 -0.6 10/31/2005 23:20:00 11.8 2.6 19.1 5.7 11.6 2.6 18.3 6.5 116 18 127 305 -0.5 0 0.1 -0.6 10/31/2005 23:30:00 11.4 2.6 20.2 5.3 11.1 2.4 20.6 4.9 114 19 101 305 -0.5 0 0.1 -0.6 10/31/2005 23:40:00 12.2 2.7 18.3 4.6 12 2.7 19.9 5.7 117 16 96 305 -0.5 0 0.1 -0.6 10/31/2005 23:50:00 10.9 2.4 17.2 5.3 10.7 2.4 17.2 6.1 113 19 109 305 -0.5 0 0.1 -0.6 11/01/2005 00:00:00 10.1 3.2 18.3 4.2 10 3.1 18.3 4.2 117 18 132 305 -0.5 0 -0.1 -0.6 11/01/2005 00:10:00 11.2 2.5 17.6 5.3 10.9 2.6 17.2 5.7 111 18 96 305 -0.5 0 0.1 -0.6 11/01/2005 00:20:00 12.1 2.9 20.2 4.9 11.9 2.8 18.7 5.7 109 18 131 305 -0.5 0 -0.1 -0.6 11/01/2005 00:30:00 10.3 2.4 16.4 4.2 10.3 2.5 17.6 5.3 108 17 88 305 -0.5 0.1 0.1 -0.6 11/01/2005 00:40:00 10.7 2.2 17.9 5.7 10.3 2.2 15.6 5.7 109 15 118 305 -0.5 0 -0.1 -0.6 11/01/2005 00:50:00 11 3.1 19.5 4.9 10.6 2.9 18.7 3 113 19 113 305 -0.5 0 0.1 -0.6 11/01/2005 01:00:00 9.9 2.5 17.9 4.2 9.9 2.3 17.2 5.3 113 21 119 305 -0.4 0.1 0.1 -0.6 11/01/2005 01:10:00 10.1 2.3 16.8 4.6 9.8 2.2 17.2 3.8 111 20 96 305 -0.4 0 0.1 -0.6 11/01/2005 01:20:00 10.6 2.4 19.1 4.9 10.4 2.4 19.1 5.3 108 18 96 305 -0.4 0 0.1 -0.6 11/01/2005 01:30:00 10.4 2.4 16.8 5.3 10.2 2.2 16.8 4.9 111 19 101 305 -0.4 0.1 0.1 -0.6 11/01/2005 01:40:00 9.7 2.6 17.2 4.2 9.2 2.5 16.8 4.6 113 17 114 305 -0.4 0.1 0.1 -0.6 11/01/2005 01:50:00 10.1 2.9 17.2 3.4 9.9 3.1 18.3 3.8 110 18 103 305 -0.4 0 0.1 -0.6 11/01/2005 02:00:00 8.9 2.3 15.3 3.4 8.7 2.3 14.9 4.2 112 21 118 305 -0.4 0 0.1 -0.6 11/01/2005 02:10:00 10.2 2.1 18.3 5.7 10 2.1 17.6 5.3 111 18 108 305 -0.4 0 0.1 -0.4 11/01/2005 02:20:00 9.5 2.4 16.8 4.2 9.6 2.5 16.4 4.6 113 17 93 305 -0.4 0 0.1 -0.4 11/01/2005 02:30:00 8.8 2 14.9 4.9 8.5 2 14.5 4.2 114 17 106 305 -0.3 0 0.1 -0.4 11/01/2005 02:40:00 8.6 2.3 15.3 3.8 8.4 2.3 15.6 4.2 100 19 92 305 -0.3 0 0.1 -0.4 11/01/2005 02:50:00 10 2.6 16.1 4.6 9.7 2.5 16.1 4.2 114 19 101 305 -0.4 0 0.1 -0.6 11/01/2005 03:00:00 7.8 2.2 15.6 2.6 7.6 2.1 14.9 2.6 111 23 88 305 -0.4 0.1 0.1 -0.6 11/01/2005 03:10:00 8.2 3.1 15.6 1.9 8 2.9 15.3 1.5 101 23 98 305 -0.5 0 0.1 -0.6 11/01/2005 03:20:00 7.4 2.3 14.5 2.3 7.1 2.2 14.1 1.9 102 24 98 305 -0.5 0 0.1 -0.6 11/01/2005 03:30:00 6.3 2 11.5 1.9 6.2 1.9 12.6 1.9 101 26 82 305 -0.5 0 0.1 -0.6 11/01/2005 03:40:00 6.8 1.9 12.2 3 6.9 1.7 11.8 3.4 88 27 84 305 -0.5 0 -0.1 -0.6 11/01/2005 03:50:00 8 2.3 14.1 3 7.7 2.1 13.7 3.4 93 27 111 305 -0.5 0 -0.1 -0.6 11/01/2005 04:00:00 7.6 2.1 13 1.9 7.5 2.1 13.3 1.5 100 26 78 305 -0.5 0.1 0.1 -0.6 11/01/2005 04:10:00 7.9 1.9 14.1 3.4 7.7 1.7 13.7 3.8 99 23 111 305 -0.5 0 0.1 -0.6 11/01/2005 04:20:00 7.5 2.1 15.3 2.3 7.3 2 13.7 2.3 93 26 111 305 -0.5 0.1 0.1 -0.6 11/01/2005 04:30:00 8.7 2.4 15.6 3.4 8.5 2.3 15.3 3 104 23 84 305 -0.4 0.1 0.1 -0.6 11/01/2005 04:40:00 7.7 2 13 3 7.5 2.1 15.6 2.3 93 22 77 305 -0.4 0 0.1 -0.6 11/01/2005 04:50:00 7.6 1.7 13.3 3.4 7.5 1.7 14.1 3.8 94 17 92 305 -0.3 0 0.3 -0.4 11/01/2005 05:00:00 3.2 1.2 6.5 0.7 3.1 1.2 6.5 1.1 112 24 111 305 -0.1 0 0.3 -0.4 11/01/2005 05:10:00 4.7 1.5 7.6 1.5 4.8 1.4 7.2 1.9 197 13 221 305 -0.1 0 0.6 -0.4 11/01/2005 05:20:00 7.2 0.7 8.8 5.3 7 0.7 8.4 5.3 223 6 227 305 0 0 0.6 -0.1 11/01/2005 05:30:00 7.8 0.9 9.1 4.9 7.4 0.9 8.8 5.3 234 5 235 305 0 0 0.3 -0.1 11/01/2005 05:40:00 8.5 0.8 9.9 6.1 7.9 0.8 9.5 5.3 233 4 232 305 0 0.1 0.6 0.1 11/01/2005 05:50:00 8.2 1 9.9 5.7 7.7 1 9.5 5.3 232 5 231 305 0.2 0 0.6 0.1 11/01/2005 06:00:00 9.6 0.8 11.1 6.8 8.9 0.9 10.7 6.5 227 4 220 305 0.3 0 0.8 0.3 11/01/2005 06:10:00 8.5 0.8 10.3 6.5 7.9 0.9 9.9 6.1 232 5 230 305 0.3 0 0.8 0.3 11/01/2005 06:20:00 7.9 0.8 9.5 5.7 7.4 0.8 9.5 5.3 225 6 224 305 0.5 0 1 0.3 11/01/2005 06:30:00 7.4 0.6 8.8 5.7 7.1 0.6 8.8 5.3 219 5 224 305 0.5 0 1 0.6 11/01/2005 06:40:00 7 0.5 8 5.7 6.9 0.5 8.4 5.3 216 4 214 305 0.5 0 1 0.6 11/01/2005 06:50:00 7.2 0.6 8.4 4.9 7.1 0.7 8.4 4.6 216 4 223 305 0.5 0 1 0.6 11/01/2005 07:00:00 6.6 0.6 8 4.6 6.3 0.7 7.6 4.2 222 5 225 305 0.5 0 1 0.6 11/01/2005 07:10:00 6.2 0.5 7.2 4.6 5.6 0.6 6.8 3.4 224 4 205 305 0.6 0.1 1 0.6 11/01/2005 07:20:00 6.5 0.6 8 3.8 6 0.7 7.6 4.2 220 4 220 305 0.7 0 1.3 0.6 11/01/2005 07:30:00 6.9 0.5 8 5.3 6.6 0.6 7.6 4.6 214 5 216 305 0.9 0 1.5 0.6 11/01/2005 07:40:00 6.9 0.7 8.4 4.2 6.4 0.8 8 4.6 210 6 212 305 1 0.1 1.5 0.8 11/01/2005 07:50:00 6.9 0.4 8 5.3 6.7 0.4 8.8 5.3 203 4 208 305 1.1 0.1 1.5 1 11/01/2005 08:00:00 6.8 0.4 7.6 6.1 6.8 0.4 7.6 5.3 200 3 202 305 1 0 1.5 1 11/01/2005 08:10:00 6 0.3 6.8 5.3 6 0.4 7.2 4.6 196 3 198 305 1 0 1.5 0.8 11/01/2005 08:20:00 5.6 0.3 6.5 4.9 5.6 0.4 6.5 4.2 193 3 196 305 1 0 1.5 0.8 11/01/2005 08:30:00 5.5 0.3 6.1 4.9 5.9 0.4 6.8 4.2 191 3 200 305 1.1 0.1 1.5 1 11/01/2005 08:40:00 5.9 0.4 6.8 4.9 6.5 0.4 7.6 5.3 189 3 184 305 1.2 0.1 1.7 1 11/01/2005 08:50:00 5.4 0.4 6.5 4.2 6 0.4 6.8 4.6 190 3 193 305 1.3 0.1 2 1 11/01/2005 09:00:00 4.7 0.4 5.7 3.8 4.9 0.5 5.7 3.8 195 5 194 305 1.3 0 2 1.3 11/01/2005 09:10:00 4.6 0.3 5.3 3.8 4.8 0.4 5.7 3.8 201 6 196 305 1.4 0 2 1.3 11/01/2005 09:20:00 4.7 0.4 6.1 3.4 4.4 0.5 5.3 3 211 4 211 305 1.4 0.1 2 1.3 11/01/2005 09:30:00 5.3 0.4 6.1 4.2 4.8 0.5 6.1 3.4 212 4 211 305 1.4 0 2 1.3 11/01/2005 09:40:00 5.2 0.5 6.1 3.8 4.9 0.5 6.1 3 215 6 211 305 1.5 0 2 1.3 11/01/2005 09:50:00 4.8 0.8 6.5 2.6 4.5 0.8 6.1 2.6 208 7 199 305 1.4 0 2 1.3 11/01/2005 10:00:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 198 5 211 305 1.4 0 1.5 1.3 11/01/2005 10:10:00 4.1 0.3 4.9 3 4 0.3 4.9 3 202 6 198 305 1.6 0 2.2 1.5 11/01/2005 10:20:00 3.9 0.3 4.6 3 3.9 0.3 4.9 3 200 6 203 305 1.6 0 2.2 1.5 11/01/2005 10:30:00 3.9 0.3 4.6 2.6 4 0.3 4.9 3 193 5 192 305 1.6 0 2 1.5 11/01/2005 10:40:00 3.9 0.4 4.9 3 3.9 0.3 4.9 3 192 5 198 305 1.6 0 2.2 1.5 11/01/2005 10:50:00 4.2 0.4 4.9 3 4.4 0.4 5.3 3.4 189 4 189 305 1.6 0 2 1.5 11/01/2005 11:00:00 5 0.3 5.7 4.2 5.2 0.3 5.7 3.8 190 4 189 305 1.6 0 2.2 1.3 11/01/2005 11:10:00 5.1 0.5 6.5 3 5.4 0.4 6.1 3.8 189 5 193 305 1.5 0 2 1.3 11/01/2005 11:20:00 4.8 0.4 5.7 3 5 0.4 5.7 3.8 189 4 198 305 1.5 0 2 1.3 11/01/2005 11:30:00 4.9 0.5 5.7 3 5.2 0.5 6.8 3.8 191 6 190 305 1.6 0 2.2 1.5 11/01/2005 11:40:00 4.2 0.5 6.1 2.6 4.2 0.5 5.7 3 197 9 194 305 1.6 0 2.2 1.5 11/01/2005 11:50:00 3.1 0.4 4.2 1.9 3.1 0.4 4.2 2.3 202 7 192 305 1.6 0 2.2 1.5 11/01/2005 12:00:00 3.3 0.4 4.2 2.3 3.4 0.4 4.6 2.6 191 5 197 305 1.6 0 2.2 1.5 11/01/2005 12:10:00 2.9 0.3 3.8 2.3 2.9 0.3 3.8 1.9 200 6 205 305 1.6 0.1 2.2 1.5 11/01/2005 12:20:00 2.5 0.4 3.4 1.1 2.5 0.4 3.4 1.5 192 5 185 305 1.6 0 2.2 1.5 11/01/2005 12:30:00 2.9 0.3 3.8 2.3 2.9 0.3 3.8 2.3 195 5 198 305 1.6 0.1 2.2 1.5 11/01/2005 12:40:00 2.6 0.4 3.8 1.5 2.8 0.3 3.8 2.3 193 5 199 305 1.7 0.1 2.2 1.5 11/01/2005 12:50:00 2.5 0.3 3.4 1.5 2.8 0.3 3.4 1.9 186 5 183 305 1.7 0.1 2.2 1.5 11/01/2005 13:00:00 2.1 0.5 3 0.7 2.9 0.3 3.8 1.9 177 3 178 305 1.9 0.1 2.5 1.5 11/01/2005 13:10:00 2.2 0.6 3.8 0.7 3.2 0.4 4.2 2.3 163 6 154 305 2 0.1 2.5 1.7 11/01/2005 13:20:00 2 0.5 3.4 1.1 3.6 0.3 4.2 2.6 166 5 159 305 1.9 0 2.5 1.7 11/01/2005 13:30:00 2.5 0.6 3.8 1.1 3.7 0.3 4.6 2.6 172 7 181 305 1.9 0.1 2.2 1.7 11/01/2005 13:40:00 2.2 0.5 3.8 1.1 3.8 0.4 4.6 2.6 171 4 175 305 1.9 0 2.5 1.7 11/01/2005 13:50:00 2.6 0.6 4.2 1.1 4 0.4 4.9 3 172 6 178 305 1.9 0.2 2.5 1.5 11/01/2005 14:00:00 2.8 0.7 4.6 1.5 4.3 0.3 4.9 3.4 174 7 182 305 1.5 0 2 1.3 11/01/2005 14:10:00 3 0.7 4.2 1.5 4 0.4 4.9 2.6 176 6 181 305 1.6 0.1 2.2 1.5 11/01/2005 14:20:00 2.6 0.6 4.2 1.5 3.8 0.4 4.9 2.6 173 6 171 305 1.8 0.1 2.5 1.5 11/01/2005 14:30:00 2.1 0.5 3.4 1.1 3.5 0.4 4.6 2.6 171 6 184 305 1.7 0.2 2.2 1.5 11/01/2005 14:40:00 2.2 0.6 3.4 1.1 3 0.6 4.9 1.5 175 8 181 305 1.6 0 2.2 1.5 11/01/2005 14:50:00 2.3 0.6 4.2 1.1 3.3 0.6 4.6 1.5 173 9 172 305 1.7 0.1 2.2 1.5 11/01/2005 15:00:00 2.2 0.7 4.2 0.7 3 0.6 4.2 1.5 176 9 179 305 1.9 0 2.5 1.7 11/01/2005 15:10:00 2.7 0.6 3.8 1.1 3.3 0.5 4.2 1.5 176 6 174 305 2 0 2.5 1.7 11/01/2005 15:20:00 2.4 0.6 3.8 1.1 3.2 0.5 4.2 1.5 176 7 186 305 1.9 0.1 2.5 1.7 11/01/2005 15:30:00 2.6 0.6 4.2 1.1 4 0.3 4.9 3 164 7 156 305 1.7 0.2 2.2 1.5 11/01/2005 15:40:00 2.6 0.7 4.6 0.7 3.6 0.5 4.6 2.6 161 8 175 305 1.6 0 2.2 1.5 11/01/2005 15:50:00 2 0.7 3.4 0.4 2.7 0.6 3.8 1.1 173 12 179 305 1.7 0.2 2.2 1.5 11/01/2005 16:00:00 2.6 0.7 3.8 0.7 3.4 0.5 4.6 2.3 162 9 158 305 1.6 0 2.2 1.3 11/01/2005 16:10:00 1.6 1.1 4.2 0.4 2.3 1.1 4.2 0.4 160 26 149 305 1.5 0 2 1.3 11/01/2005 16:20:00 0.5 0.4 2.6 0.4 0.7 0.5 2.6 0.4 189 72 159 305 1.6 0.1 2.2 1.5 11/01/2005 16:30:00 1.7 1.3 4.2 0.4 1.6 1.2 4.2 0.4 182 69 145 305 1.6 0.1 2.2 1.3 11/01/2005 16:40:00 2.6 1.2 4.6 0.4 2.6 1.1 4.6 0.4 154 19 138 305 1.4 0.1 2 1.3 11/01/2005 16:50:00 3.4 1.3 4.9 0.4 3.4 1.2 5.3 1.1 140 12 135 305 1.4 0 2 1.3 11/01/2005 17:00:00 3.8 0.8 5.3 1.1 4.1 0.8 5.3 1.5 137 11 127 305 1.3 0 2 1.3 11/01/2005 17:10:00 3.5 0.9 5.3 0.4 3.9 0.8 5.3 1.5 131 10 139 305 1.4 0 2 1.3 11/01/2005 17:20:00 2.6 0.7 4.2 0.7 3.3 0.6 4.6 1.5 120 15 131 305 1.4 0 2 1.3 11/01/2005 17:30:00 1.8 0.8 3.4 0.4 2.5 0.6 3.8 1.1 129 20 121 305 1.6 0 2.2 1.5 11/01/2005 17:40:00 2.5 0.8 4.6 0.4 3 0.8 5.7 0.7 144 13 150 305 1.6 0 2.2 1.5 11/01/2005 17:50:00 3.2 1.1 4.9 0.4 3.9 0.8 5.3 1.9 141 10 136 305 1.6 0 2.2 1.3 11/01/2005 18:00:00 3.3 0.6 4.6 1.1 4.1 0.5 4.9 2.6 135 8 138 305 1.5 0.1 2 1.3 11/01/2005 18:10:00 4.1 0.8 5.7 1.9 4.5 0.6 6.1 3 135 6 140 305 1.6 0.1 2.2 1.3 11/01/2005 18:20:00 4.2 0.5 5.3 2.6 4.8 0.4 5.7 3.8 129 5 131 305 1.3 0.1 1.7 1 11/01/2005 18:30:00 2.8 0.8 5.3 0.7 3.6 0.6 5.7 2.3 126 13 130 305 1.2 0.1 1.5 1 11/01/2005 18:40:00 3.2 0.9 5.3 1.1 3.7 0.8 6.1 2.3 127 10 129 305 1.2 0.1 1.7 1 11/01/2005 18:50:00 2.5 1.2 4.9 0.4 3.2 0.9 4.9 0.7 139 18 151 305 1.2 0.1 1.7 1 11/01/2005 19:00:00 3.2 1.8 5.3 0.4 3.5 1.8 5.7 0.4 130 49 130 305 1.2 0.1 1.7 1 11/01/2005 19:10:00 4 0.8 5.3 1.9 4.5 0.7 6.1 2.3 130 9 134 305 1 0 1.5 0.8 11/01/2005 19:20:00 3.6 0.8 5.7 1.5 3.8 0.9 5.3 1.1 133 9 134 305 1.1 0 1.5 1 11/01/2005 19:30:00 2.9 1.2 4.9 0.4 3 1.1 4.9 0.4 135 10 140 305 1.3 0.1 2 1 11/01/2005 19:40:00 1.9 0.7 3 0.4 2.3 0.6 3.8 0.7 102 13 128 305 1.6 0.1 2.2 1.5 11/01/2005 19:50:00 0.9 0.5 2.3 0.4 1.4 0.7 3 0.4 85 22 92 305 1.6 0 2.2 1.5 11/01/2005 20:00:00 0.7 0.4 1.5 0.4 1.2 0.4 2.3 0.4 24 35 101 305 1.6 0.1 2.2 1.5 11/01/2005 20:10:00 1.4 0.5 2.6 0.4 1.8 0.5 2.6 0.4 123 53 75 305 1.6 0.1 2.2 1.5 11/01/2005 20:20:00 0.7 0.6 2.3 0.4 1 0.6 2.6 0.4 121 39 93 305 1.5 0 2 1.3 11/01/2005 20:30:00 0.4 0 0.4 0.4 0.4 0.1 1.5 0.4 65 0 305 305 1.4 0.1 2 1.3 11/01/2005 20:40:00 0.4 0.2 1.5 0.4 0.5 0.4 1.9 0.4 137 47 150 305 1.4 0 2 1.3 11/01/2005 20:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 55 30 19 305 1.6 0.1 2.2 1.3 11/01/2005 21:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 35 35 305 305 1.6 0 2.2 1.5 11/01/2005 21:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 63 28 305 305 1.6 0.1 2.2 1.5 11/01/2005 21:20:00 0.5 0.4 2.3 0.4 0.6 0.4 2.3 0.4 142 112 127 305 1.6 0 2.2 1.5 11/01/2005 21:30:00 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 330 58 196 305 1.6 0.1 2.2 1.5 11/01/2005 21:40:00 0.9 0.8 3.8 0.4 1 0.7 3 0.4 147 61 134 305 1.6 0 2.2 1.3 11/01/2005 21:50:00 1 1 4.2 0.4 1.1 0.9 3.8 0.4 170 49 113 305 1.4 0 2 1.3 11/01/2005 22:00:00 4.7 0.7 6.1 2.6 4.7 0.8 6.1 2.6 116 4 113 305 1.3 0.1 2 1 11/01/2005 22:10:00 4.7 0.6 6.1 3.4 5 0.5 6.1 3.4 109 7 110 305 1.4 0 2 1.3 11/01/2005 22:20:00 4.8 0.9 6.1 2.3 4.9 0.8 6.1 2.6 107 11 108 305 1.5 0 2 1.3 11/01/2005 22:30:00 4.3 1 6.5 0.7 4.4 0.8 6.1 1.9 109 13 107 305 1.6 0 2 1.3 11/01/2005 22:40:00 4.2 0.9 6.5 2.3 4.4 0.8 6.5 2.3 110 11 118 305 1.6 0 2.2 1.5 11/01/2005 22:50:00 4.4 0.8 6.1 1.5 4.6 0.8 6.5 2.3 117 9 110 305 1.6 0 2.2 1.5 11/01/2005 23:00:00 4.4 1 6.1 0.7 4.7 0.7 6.5 1.9 110 12 116 305 1.6 0 2.2 1.5 11/01/2005 23:10:00 4.9 0.6 6.1 2.6 5 0.6 6.1 3 112 6 106 305 1.5 0 2 1.3 11/01/2005 23:20:00 5.9 0.5 7.2 4.6 5.8 0.5 7.2 3.8 113 4 113 305 1.6 0 2 1.3 11/01/2005 23:30:00 6.5 0.5 7.6 4.6 6.2 0.5 7.2 4.6 108 5 106 305 1.6 0.1 2.2 1.5 11/01/2005 23:40:00 6.4 0.7 8 4.9 5.9 0.7 7.6 4.6 98 3 104 305 1.6 0.1 2.2 1.5 11/01/2005 23:50:00 5.6 0.5 6.5 4.2 5 0.5 6.1 4.2 94 5 92 305 1.6 0 2.2 1.5 11/02/2005 00:00:00 5.3 0.5 6.8 3.4 4.7 0.6 6.1 3 92 6 97 305 1.5 0 2 1.3 11/02/2005 00:10:00 4.9 0.4 6.1 3.8 4.4 0.4 5.3 3 83 5 85 305 1.6 0.1 2 1.3 11/02/2005 00:20:00 4.7 0.6 6.1 3 4.2 0.6 5.3 2.3 89 9 87 305 1.5 0.2 2 1.3 11/02/2005 00:30:00 4.6 0.5 5.7 3.4 4.3 0.6 5.7 3 107 6 101 305 1.4 0.1 2 1.3 11/02/2005 00:40:00 3.7 0.6 5.3 1.9 3.5 0.5 4.9 1.9 112 6 112 305 1.4 0.2 2 1.3 11/02/2005 00:50:00 2.3 1.2 4.6 0.4 2 1.1 4.2 0.4 117 22 126 305 1.4 0.1 2 1.3 11/02/2005 01:00:00 1.4 0.9 3.4 0.4 1.9 0.9 3.4 0.4 14 72 22 305 1.6 0.1 2.2 1.3 11/02/2005 01:10:00 3.4 0.7 4.6 0.4 3.6 0.7 4.6 1.5 34 14 27 305 1.7 0.2 2.2 1.5 11/02/2005 01:20:00 3.6 0.5 5.3 2.3 3.7 0.6 5.7 1.9 63 12 56 305 1.7 0.1 2 1.3 11/02/2005 01:30:00 3.2 0.3 4.2 2.6 3.3 0.3 4.2 2.6 60 4 63 305 1.6 0 2 1.3 11/02/2005 01:40:00 3.1 0.4 3.8 1.9 3 0.4 4.2 1.9 62 5 54 305 1.5 0.1 2 1.3 11/02/2005 01:50:00 3.6 0.3 4.6 2.6 3.6 0.4 4.6 3 55 4 50 305 1.6 0 2 1.3 11/02/2005 02:00:00 4 0.5 4.9 3 4.1 0.5 4.9 3 43 6 37 305 1.5 0 2 1.3 11/02/2005 02:10:00 5.4 0.4 6.5 4.2 5.6 0.4 6.5 3.8 36 3 35 305 1.4 0 2 1.3 11/02/2005 02:20:00 5.4 0.3 6.1 4.6 5.5 0.3 6.1 4.6 32 2 31 305 1.4 0 2 1.3 11/02/2005 02:30:00 5.4 0.4 6.1 4.6 5.6 0.4 6.5 4.9 33 3 32 305 1.4 0 2 1.3 11/02/2005 02:40:00 6 0.6 7.6 4.6 6.2 0.7 7.6 4.6 37 3 36 305 1.4 0 2 1.3 11/02/2005 02:50:00 6.9 0.6 8 5.7 7 0.6 8.4 5.7 42 4 44 305 1.5 0 2 1.3 11/02/2005 03:00:00 8.1 0.6 9.5 6.8 8.2 0.6 9.5 6.5 43 4 42 305 1.3 0.2 1.7 1 11/02/2005 03:10:00 8.4 0.5 9.1 7.2 8.6 0.5 9.5 7.2 46 2 50 305 1 0 1.5 0.8 11/02/2005 03:20:00 8.4 0.5 9.5 6.8 8.5 0.5 9.5 6.8 48 2 47 305 0.9 0 1.5 0.8 11/02/2005 03:30:00 8.2 0.6 9.5 6.1 8.3 0.7 9.5 6.1 45 3 48 305 0.9 0 1.3 0.8 11/02/2005 03:40:00 8.7 0.6 10.3 6.1 8.8 0.7 10.7 5.7 48 4 50 305 0.9 0 1.3 0.6 11/02/2005 03:50:00 9.8 0.6 11.1 6.8 9.8 0.8 11.1 5.7 48 2 48 305 0.7 0.1 1.3 0.6 11/02/2005 04:00:00 10.1 0.8 11.5 8.4 10 0.9 11.8 7.6 51 3 52 305 0.6 0.1 1.3 0.6 11/02/2005 04:10:00 10.6 0.7 12.2 8.8 10.6 0.8 12.2 8.4 49 3 47 305 0.5 0 1 0.6 11/02/2005 04:20:00 10.9 0.8 12.6 8 10.9 1 12.6 8 46 3 45 305 0.5 0 1 0.3 11/02/2005 04:30:00 11.5 0.7 13.3 9.5 11.5 0.7 13 9.1 45 4 46 305 0.4 0 1 0.3 11/02/2005 04:40:00 11.7 0.7 13 9.5 11.7 0.7 13.3 9.1 41 3 40 305 0.3 0.1 0.8 0.1 11/02/2005 04:50:00 12 0.8 13.7 9.5 12 0.9 14.1 9.5 40 3 41 305 0 0.1 0.6 -0.1 11/02/2005 05:00:00 12 0.7 13.7 8.8 12 0.8 13.7 9.1 41 5 45 305 0 0 0.6 -0.4 11/02/2005 05:10:00 12.1 0.9 14.1 8.8 12.1 1 14.1 9.1 40 3 42 305 -0.1 0 0.6 -0.4 11/02/2005 05:20:00 11.5 0.9 13.3 9.5 11.5 1 13.7 9.1 38 3 38 305 -0.2 0.1 0.3 -0.4 11/02/2005 05:30:00 11.9 0.8 13.7 9.1 11.9 0.8 13.7 9.5 38 4 39 305 -0.4 0.1 0.1 -0.6 11/02/2005 05:40:00 12.1 0.7 13.3 10.3 12 0.8 13.7 9.9 40 3 37 305 -0.5 0.1 0.1 -0.6 11/02/2005 05:50:00 12.2 0.7 14.1 9.5 12.2 0.8 14.1 8.8 37 2 38 305 -0.5 0 0.1 -0.6 11/02/2005 06:00:00 12.2 0.6 13.3 9.9 12.2 0.6 13.3 10.7 36 2 33 305 -0.5 0 0.1 -0.6 11/02/2005 06:10:00 11.8 0.9 13.3 9.1 11.7 1 13.7 8.8 39 2 36 305 -0.5 0.1 0.1 -0.6 11/02/2005 06:20:00 12.2 0.6 13.3 10.7 12.3 0.6 13.3 10.3 37 2 36 305 -0.6 0 0.1 -0.8 11/02/2005 06:30:00 11.9 0.7 13.3 9.5 11.9 0.8 13.3 9.5 35 2 34 305 -0.7 0 -0.1 -0.8 11/02/2005 06:40:00 12.1 0.5 13.3 10.7 12.1 0.6 13.3 10.7 37 2 36 305 -0.7 0 -0.1 -0.8 11/02/2005 06:50:00 11.9 0.6 13.3 9.5 11.9 0.7 13.3 9.5 36 3 35 305 -0.7 0.1 -0.1 -1.1 11/02/2005 07:00:00 11.4 0.9 13.3 8.8 11.3 1 13.3 8.8 34 3 35 305 -0.8 0.1 -0.1 -1.1 11/02/2005 07:10:00 11.4 0.8 13 9.1 11.4 0.8 13.3 9.1 32 1 31 305 -0.9 0.1 -0.4 -1.1 11/02/2005 07:20:00 11.7 0.7 13.3 9.1 11.7 0.8 13.7 9.1 30 2 28 305 -1 0.1 -0.4 -1.1 11/02/2005 07:30:00 11.8 0.6 13 9.9 11.9 0.6 13.7 9.9 28 1 27 305 -1 0.1 -0.4 -1.1 11/02/2005 07:40:00 11.3 0.7 12.6 9.1 11.3 0.8 13 9.1 29 2 27 305 -0.9 0.1 -0.4 -1.1 11/02/2005 07:50:00 11 1.1 13.3 8 11.1 1.1 13.3 8.8 30 2 26 305 -1 0.1 -0.4 -1.1 11/02/2005 08:00:00 11.1 0.9 12.6 8.8 11.1 0.9 13.3 8.8 29 2 26 305 -1 0.1 -0.4 -1.3 11/02/2005 08:10:00 10.6 0.8 12.2 8.4 10.7 0.9 12.2 8.4 31 2 32 305 -1 0.1 -0.4 -1.1 11/02/2005 08:20:00 10.9 0.6 12.6 9.1 10.9 0.7 12.2 8.8 30 2 30 305 -1.1 0 -0.6 -1.3 11/02/2005 08:30:00 10.7 0.8 12.6 8.4 10.7 0.8 12.6 8.8 32 2 33 305 -1.1 0 -0.6 -1.3 11/02/2005 08:40:00 10.8 0.8 12.6 8.4 10.8 0.9 12.6 7.6 31 3 32 305 -1.1 0 -0.6 -1.3 11/02/2005 08:50:00 10.9 0.6 12.2 8.4 11 0.6 12.6 8.4 31 3 32 305 -1.1 0 -0.6 -1.3 11/02/2005 09:00:00 10.6 0.7 12.2 8.4 10.6 0.8 12.2 8.4 33 3 30 305 -1 0.1 -0.6 -1.1 11/02/2005 09:10:00 10.7 0.8 12.6 8.4 10.7 0.8 12.2 8.4 32 5 27 305 -1 0.1 -0.4 -1.1 11/02/2005 09:20:00 10.6 0.8 12.6 8.8 10.7 0.8 13 8.4 27 3 23 305 -1 0.1 -0.6 -1.3 11/02/2005 09:30:00 10.8 0.7 12.2 8.8 11 0.8 12.6 8.8 24 3 19 305 -1.1 0 -0.6 -1.3 11/02/2005 09:40:00 10.9 0.8 12.6 8.8 11 0.8 12.6 8.8 23 3 19 305 -1.4 0 -1.1 -1.5 11/02/2005 09:50:00 10.7 0.7 12.2 8.4 10.9 0.8 12.6 8.4 24 2 24 305 -1.5 0.1 -1.3 -1.8 11/02/2005 10:00:00 10.3 0.6 12.2 8.8 10.5 0.7 13 8.4 24 5 19 305 -1.5 0.1 -1.1 -1.8 11/02/2005 10:10:00 10.7 0.6 12.2 8.8 10.9 0.6 12.6 9.5 26 3 23 305 -1.6 0 -1.1 -1.8 11/02/2005 10:20:00 10.7 0.6 12.2 8.8 10.8 0.7 12.2 9.1 29 2 23 305 -1.6 0 -1.1 -1.8 11/02/2005 10:30:00 10.7 0.6 12.6 8.8 10.8 0.7 12.2 8.8 29 4 26 305 -1.6 0 -1.1 -1.8 11/02/2005 10:40:00 10.8 0.6 13 9.1 10.9 0.7 13.3 9.1 30 3 26 305 -1.6 0 -1.1 -1.8 11/02/2005 10:50:00 10.2 0.7 11.8 8.4 10.3 0.7 11.8 8.8 31 3 30 305 -1.6 0 -1.1 -1.8 11/02/2005 11:00:00 10.6 0.7 12.2 8.4 10.7 0.8 12.6 8.4 31 3 29 305 -1.6 0 -1.1 -1.8 11/02/2005 11:10:00 10.8 0.6 12.2 9.5 11 0.6 12.6 9.1 28 3 24 305 -1.7 0 -1.8 -2 11/02/2005 11:20:00 10.7 0.6 12.2 9.1 10.8 0.6 12.6 8.8 33 3 32 305 -1.8 0 -1.3 -2 11/02/2005 11:30:00 10.4 0.6 11.8 8.8 10.6 0.6 12.2 8.4 30 3 32 305 -1.8 0 -1.5 -2 11/02/2005 11:40:00 10.3 0.8 12.2 8.4 10.5 0.9 12.6 8.4 26 4 25 305 -1.8 0 -1.3 -2 11/02/2005 11:50:00 10.4 0.7 12.2 8.8 10.6 0.7 12.6 8.8 23 3 22 305 -1.8 0 -1.3 -2 11/02/2005 12:00:00 10.6 0.7 12.2 8.8 10.8 0.7 12.2 9.1 25 3 23 305 -1.8 0 -1.8 -2 11/02/2005 12:10:00 10.3 0.7 12.2 8.4 10.6 0.7 12.6 8.8 23 3 17 305 -1.8 0 -1.3 -2 11/02/2005 12:20:00 10.6 0.6 11.8 8.8 10.9 0.6 12.2 9.1 20 3 19 305 -1.8 0 -1.8 -2 11/02/2005 12:30:00 10.1 0.7 11.8 8 10.4 0.8 11.8 8 20 3 21 305 -1.8 0 -1.3 -2 11/02/2005 12:40:00 10.4 0.8 12.2 8 10.6 0.8 12.2 8.4 20 3 14 305 -1.9 0 -1.5 -2 11/02/2005 12:50:00 10.8 0.6 12.2 8.8 11 0.6 12.6 9.1 25 3 23 305 -1.9 0 -1.8 -2 11/02/2005 13:00:00 10.3 0.5 11.5 8.4 10.6 0.6 12.2 8.8 23 3 30 305 -2 0 -1.8 -2 11/02/2005 13:10:00 10.4 0.7 11.8 8.4 10.6 0.8 12.6 8.4 22 3 17 305 -2 0 -1.8 -2.2 11/02/2005 13:20:00 9.8 0.6 11.5 7.6 10 0.7 11.8 7.6 24 3 24 305 -2 0 -1.8 -2.2 11/02/2005 13:30:00 9.8 0.8 11.5 7.6 10 0.9 12.2 8 23 4 30 305 -2.1 0 -2 -2.2 11/02/2005 13:40:00 10.1 0.8 11.5 8 10.4 0.8 11.8 8.4 16 3 15 305 -2.2 0 -2 -2.2 11/02/2005 13:50:00 10.2 0.8 11.8 8 10.4 0.9 12.2 7.6 19 6 14 305 -2.2 0 -2 -2.4 11/02/2005 14:00:00 10.2 0.6 11.8 8.8 10.5 0.6 12.2 8.4 18 4 19 305 -2.3 0 -2 -2.4 11/02/2005 14:10:00 10.2 0.6 12.2 8.4 10.5 0.7 12.2 8.4 17 3 19 305 -2.3 0 -2.2 -2.4 11/02/2005 14:20:00 9.9 0.6 11.5 8 10.1 0.7 11.8 8.4 24 6 17 305 -2.4 0 -2.2 -2.7 11/02/2005 14:30:00 10.2 0.5 11.5 8.8 10.4 0.6 12.2 8.8 25 5 19 305 -2.4 0 -2 -2.7 11/02/2005 14:40:00 10.4 0.8 12.6 8.4 10.6 0.8 12.6 8.8 29 6 10 305 -2.6 0 -2.4 -2.7 11/02/2005 14:50:00 10.2 0.8 12.2 8.4 10.4 0.9 12.6 8.4 25 3 23 305 -2.4 0 -2.2 -2.7 11/02/2005 15:00:00 10.2 0.5 11.8 8.8 10.4 0.6 12.2 9.1 27 6 30 305 -2.7 0 -2.4 -2.7 11/02/2005 15:10:00 9.9 0.8 12.2 8 10 0.8 12.2 8 30 4 26 305 -2.7 0 -2.4 -2.9 11/02/2005 15:20:00 9.3 1 11.5 6.5 9.5 1 11.5 6.5 28 5 24 305 -2.6 0 -2.4 -2.7 11/02/2005 15:30:00 9.8 0.8 11.8 7.6 10 0.8 12.2 7.6 29 6 36 305 -2.6 0 -2.2 -2.7 11/02/2005 15:40:00 10 1.2 13 7.2 10.1 1.2 13 6.8 31 6 29 305 -2.6 0 -2 -2.7 11/02/2005 15:50:00 9.1 0.9 11.8 6.8 9.4 1 11.8 7.2 19 6 19 305 -2.6 0 -2.4 -2.7 11/02/2005 16:00:00 9.6 0.7 11.1 8 10 0.7 11.5 8.4 16 8 14 305 -2.6 0 -2.4 -2.7 11/02/2005 16:10:00 9.3 1 13.3 6.5 9.5 1 13.3 6.5 27 6 27 305 -2.6 0 -2 -2.7 11/02/2005 16:20:00 9 0.8 11.5 7.2 9.2 0.9 12.6 7.2 29 6 33 305 -2.6 0 -2 -2.7 11/02/2005 16:30:00 9.6 1 11.5 6.5 9.7 1 11.8 6.8 30 5 32 305 -2.6 0 -2 -2.7 11/02/2005 16:40:00 8.8 0.8 10.7 7.2 9 0.8 11.1 7.6 23 6 22 305 -2.6 0 -2.4 -2.7 11/02/2005 16:50:00 9.1 0.7 10.7 7.2 9.3 0.7 11.1 7.6 16 6 21 305 -2.5 0 -2 -2.7 11/02/2005 17:00:00 8.8 1 11.8 6.8 9.1 1 12.2 7.2 22 8 25 305 -2.6 0 -2.4 -2.7 11/02/2005 17:10:00 8.2 1.1 10.7 6.1 8.4 1.1 10.7 6.1 22 6 29 305 -2.5 0 -2.2 -2.7 11/02/2005 17:20:00 8.3 1 10.3 6.1 8.5 1 10.7 6.5 23 8 32 305 -2.4 0 -2 -2.7 11/02/2005 17:30:00 9 1 11.5 6.8 9.2 1 11.8 6.8 27 6 31 305 -2.3 0.1 -1.8 -2.4 11/02/2005 17:40:00 9.8 1.3 13.3 6.5 10 1.2 13.3 6.8 22 5 20 305 -2.2 0 -2 -2.4 11/02/2005 17:50:00 8 1.2 10.7 5.7 8.3 1.2 11.1 6.1 18 4 23 305 -2.2 0 -1.8 -2.4 11/02/2005 18:00:00 9.2 0.8 11.5 7.2 9.4 0.9 11.8 6.8 19 6 19 305 -2.2 0 -2 -2.2 11/02/2005 18:10:00 8 1.3 11.1 5.7 8.3 1.3 11.8 6.1 13 6 17 305 -2.2 0 -2 -2.4 11/02/2005 18:20:00 8.9 1 11.5 6.1 9.1 1 11.5 6.8 14 5 12 305 -2.2 0 -2 -2.4 11/02/2005 18:30:00 8.6 1 11.1 6.1 8.9 1 11.1 6.1 19 5 24 305 -2.2 0 -2 -2.4 11/02/2005 18:40:00 9.1 0.9 11.8 7.2 9.3 1 12.2 7.6 20 4 18 305 -2.1 0 -2 -2.2 11/02/2005 18:50:00 9 0.9 11.1 6.8 9.3 0.9 11.8 7.6 9 4 13 305 -2.1 0 -2 -2.2 11/02/2005 19:00:00 9.2 1 11.5 6.5 9.5 1 11.8 7.2 5 7 15 305 -2.2 0 -2 -2.4 11/02/2005 19:10:00 8.6 0.9 10.7 4.9 9 0.9 11.1 6.1 7 6 7 305 -2.2 0 -1.8 -2.4 11/02/2005 19:20:00 8.6 0.9 10.7 6.8 9 1 11.5 6.8 8 7 3 305 -2.2 0 -2 -2.2 11/02/2005 19:30:00 9.1 1.1 11.5 6.5 9.3 1.1 11.8 6.8 12 6 16 305 -2.2 0 -2 -2.2 11/02/2005 19:40:00 8.6 0.9 11.5 6.5 8.9 0.9 12.6 6.5 8 7 11 305 -2.2 0 -2 -2.4 11/02/2005 19:50:00 8.7 0.7 10.7 7.2 9 0.8 11.1 7.2 9 8 8 305 -2.2 0 -2 -2.4 11/02/2005 20:00:00 8.6 0.9 10.3 6.5 8.9 0.9 10.7 6.8 5 7 7 305 -2.1 0 -1.8 -2.2 11/02/2005 20:10:00 9.2 0.8 10.7 6.8 9.5 1 11.1 7.2 9 4 12 305 -2.2 0 -2 -2.4 11/02/2005 20:20:00 9.1 0.6 10.7 7.2 9.5 0.6 11.5 8 359 7 358 305 -2.2 0 -2 -2.4 11/02/2005 20:30:00 9.5 1 12.6 6.5 9.8 1 13.3 6.8 2 5 359 305 -2.3 0 -2 -2.4 11/02/2005 20:40:00 9.1 0.8 11.5 7.2 9.5 0.8 11.8 7.6 4 7 5 305 -2.3 0 -1.8 -2.4 11/02/2005 20:50:00 8.9 0.8 11.5 6.8 9.3 0.8 11.8 6.8 3 7 357 305 -2.3 0 -2 -2.4 11/02/2005 21:00:00 9.2 1.2 13 6.8 9.6 1.2 13.3 7.2 357 6 354 305 -2.4 0 -2.2 -2.7 11/02/2005 21:10:00 7.8 0.8 9.9 6.1 8.2 0.8 11.1 6.1 350 4 354 305 -2.6 0 -2 -2.7 11/02/2005 21:20:00 7.7 1 9.9 5.3 8 1 10.7 5.7 351 7 343 305 -2.6 0 -2.4 -2.7 11/02/2005 21:30:00 8.2 1 10.7 5.7 8.6 1 10.7 5.7 356 8 349 305 -2.6 0 -2.4 -2.7 11/02/2005 21:40:00 7.7 1.3 10.7 4.6 8.2 1.3 11.1 5.3 354 5 353 305 -2.7 0 -2.4 -2.7 11/02/2005 21:50:00 7.7 1 9.9 6.1 8.1 1 10.7 5.7 352 9 4 305 -2.7 0 -2.4 -2.7 11/02/2005 22:00:00 7.9 1 10.3 5.7 8.3 1 10.7 6.5 5 7 3 305 -2.7 0 -2.4 -2.7 11/02/2005 22:10:00 7.9 0.9 9.5 5.7 8.3 0.8 10.3 6.1 2 6 359 305 -2.7 0 -2.4 -2.9 11/02/2005 22:20:00 7.6 0.7 9.1 4.9 8 0.8 9.9 5.7 9 8 356 305 -2.8 0 -2.7 -2.9 11/02/2005 22:30:00 8.6 0.6 10.7 6.8 8.9 0.7 10.7 6.8 11 7 4 305 -2.8 0 -2.4 -2.9 11/02/2005 22:40:00 8.8 0.7 11.1 7.2 9.2 0.7 11.5 7.2 15 8 23 305 -2.8 0 -2.4 -2.9 11/02/2005 22:50:00 8.6 1.1 11.5 5.7 8.9 1.1 11.8 6.1 12 10 10 305 -2.8 0 -2.4 -3.1 11/02/2005 23:00:00 8.1 1.3 11.8 5.3 8.5 1.3 12.2 6.1 0 8 356 305 -2.8 0 -2.4 -2.9 11/02/2005 23:10:00 7.1 0.7 8.8 5.7 7.5 0.7 9.1 5.7 0 9 355 305 -3 0 -2.2 -3.1 11/02/2005 23:20:00 6.7 1 9.1 4.2 7.1 1 9.1 4.6 359 7 5 305 -3 0 -2.7 -3.1 11/02/2005 23:30:00 5.8 0.6 7.6 4.2 6.2 0.6 8 4.6 354 8 5 305 -3 0 -2.7 -3.1 11/02/2005 23:40:00 6.5 1 8.8 4.6 6.8 0.9 9.1 4.6 345 10 352 305 -2.9 0 -2.4 -3.1 11/02/2005 23:50:00 7 0.8 9.1 5.3 7.3 0.9 9.1 5.3 340 8 352 305 -2.8 0 -2.4 -3.1 11/03/2005 00:00:00 7.1 0.9 9.9 4.9 7.5 0.9 10.7 5.3 340 7 333 305 -2.7 0 -2.4 -2.9 11/03/2005 00:10:00 7.4 0.8 9.5 5.3 7.8 0.9 9.9 5.3 341 4 343 305 -2.8 0 -2.7 -2.9 11/03/2005 00:20:00 6.3 1 8 3.8 6.7 1 8.8 4.6 345 6 342 305 -2.7 0 -2.7 -2.9 11/03/2005 00:30:00 6.9 0.9 11.1 4.9 7.3 0.9 11.1 5.3 348 13 346 305 -2.6 0 -2.2 -2.7 11/03/2005 00:40:00 7.5 0.8 9.5 4.6 8 0.8 9.9 6.1 350 5 358 305 -2.6 0 -2.4 -2.7 11/03/2005 00:50:00 7.1 1 10.3 5.3 7.5 0.9 10.3 5.7 352 9 334 305 -2.7 0 -2.4 -2.7 11/03/2005 01:00:00 6.6 1 8.8 3.8 7.1 1 9.1 4.6 351 7 345 305 -2.7 0 -2.4 -2.9 11/03/2005 01:10:00 6.4 1.1 8.8 3.8 6.8 1 9.1 4.6 353 13 358 305 -2.8 0 -2.7 -2.9 11/03/2005 01:20:00 6.1 1.1 8.8 3 6.5 1.1 8.8 3.8 4 7 5 305 -2.8 0 -2.7 -3.1 11/03/2005 01:30:00 6 1.1 8.8 3.8 6.4 1.1 9.1 4.2 358 6 5 305 -2.9 0 -2.7 -3.1 11/03/2005 01:40:00 5.7 0.8 8 3.8 6 0.8 8.4 4.2 351 6 352 305 -3 0 -2.7 -3.1 11/03/2005 01:50:00 4.6 0.7 6.8 3.4 5.1 0.7 7.2 3.8 340 8 357 305 -3 0 -2.7 -3.1 11/03/2005 02:00:00 6.2 1.1 9.1 3.4 6.7 1.1 9.9 4.2 1 5 0 305 -2.9 0 -2.7 -3.1 11/03/2005 02:10:00 5.6 0.8 8.4 4.2 6 0.8 8 3.4 7 7 357 305 -3 0 -2.7 -3.1 11/03/2005 02:20:00 4.3 0.6 6.1 2.6 4.6 0.6 6.5 3 4 9 10 305 -3 0 -2.7 -3.1 11/03/2005 02:30:00 5.1 1.2 7.2 2.3 5.4 1.2 7.6 3 5 12 3 305 -2.8 0 -2.4 -3.1 11/03/2005 02:40:00 6 1 8 3.4 6.4 1 8.4 3.8 357 13 344 305 -2.8 0 -2.7 -2.9 11/03/2005 02:50:00 4.6 1.3 7.6 2.3 4.9 1.5 8 1.9 15 12 22 305 -2.9 0 -2.7 -3.1 11/03/2005 03:00:00 4.8 1 6.8 3 5.1 1 7.2 3.4 338 11 336 305 -2.9 0 -2.7 -3.1 11/03/2005 03:10:00 5 0.7 6.8 3.4 5.4 0.7 7.2 3.8 350 6 357 305 -2.9 0 -2.7 -3.1 11/03/2005 03:20:00 6 0.8 7.6 3.8 6.4 0.7 8 4.2 6 6 14 305 -2.8 0 -2.7 -3.1 11/03/2005 03:30:00 4.4 1 7.6 1.5 4.7 1 8 1.9 3 9 16 305 -3 0 -2.7 -3.1 11/03/2005 03:40:00 5.1 0.6 6.8 3.4 5.4 0.6 6.8 3.4 11 16 19 305 -3 0 -2.7 -3.1 11/03/2005 03:50:00 4.1 0.8 5.7 2.3 4.5 0.8 6.5 2.3 7 16 23 305 -3 0 -2.9 -3.1 11/03/2005 04:00:00 5 0.8 6.8 3.4 5.4 0.8 7.6 3.4 8 10 349 305 -3 0 -2.4 -3.1 11/03/2005 04:10:00 3.1 1.2 5.7 0.4 3.3 1.2 6.1 1.1 13 13 16 305 -3.1 0.1 -2.9 -3.3 11/03/2005 04:20:00 3.4 0.8 5.7 1.5 3.6 1 6.1 1.9 341 7 346 305 -3.1 0 -3.1 -3.3 11/03/2005 04:30:00 3.8 0.6 5.3 2.6 4 0.6 6.1 2.6 341 10 350 305 -3.2 0 -3.1 -3.3 11/03/2005 04:40:00 3.9 0.5 5.7 2.6 4.1 0.6 6.5 2.6 1 26 350 305 -3 0 -2.7 -3.3 11/03/2005 04:50:00 3 0.8 4.9 0.4 3.1 0.8 5.3 1.5 333 17 337 305 -3.1 0 -2.9 -3.3 11/03/2005 05:00:00 3.8 0.6 5.3 2.3 4.2 0.8 6.5 2.3 357 10 353 305 -3 0 -2.9 -3.1 11/03/2005 05:10:00 3.3 0.8 4.9 1.9 3.4 0.8 5.3 1.9 340 22 352 305 -3 0 -2.7 -3.1 11/03/2005 05:20:00 3.5 0.6 5.3 2.3 3.7 0.6 5.7 1.9 345 16 331 305 -3 0 -2.4 -3.1 11/03/2005 05:30:00 3.4 0.5 4.9 2.3 3.6 0.5 4.9 2.3 345 8 350 305 -3 0 -2.7 -3.1 11/03/2005 05:40:00 3.7 0.5 4.9 2.3 3.9 0.6 5.3 2.6 351 11 359 305 -3 0 -2.7 -3.1 11/03/2005 05:50:00 3.3 0.9 4.9 0.4 3.4 0.8 5.3 1.5 355 15 351 305 -3 0 -2.7 -3.1 11/03/2005 06:00:00 3.1 0.8 4.9 1.5 3.2 0.8 4.9 1.9 30 9 19 305 -2.9 0 -2.4 -3.1 11/03/2005 06:10:00 1.4 0.5 2.6 0.4 1.7 0.4 2.6 0.7 21 14 31 305 -2.9 0 -2.4 -3.1 11/03/2005 06:20:00 1.3 1 3.4 0.4 1.8 0.8 3.8 0.7 336 8 332 305 -2.9 0 -2.4 -3.1 11/03/2005 06:30:00 3.2 0.5 4.6 1.5 3.3 0.5 4.6 1.9 338 17 350 305 -2.8 0 -2.7 -3.1 11/03/2005 06:40:00 4 0.5 6.1 3 4.1 0.6 6.5 2.6 358 6 348 305 -2.8 0 -2.4 -2.9 11/03/2005 06:50:00 5 0.8 6.8 3.4 5.4 0.9 8 3.8 346 6 347 305 -2.8 0 -2.4 -3.1 11/03/2005 07:00:00 3.5 1 4.9 0.7 3.8 1 5.3 1.5 338 12 344 305 -2.9 0 -2.4 -3.1 11/03/2005 07:10:00 2.8 0.8 5.7 1.5 3 0.8 6.1 1.5 344 12 9 305 -2.9 0 -2.7 -3.1 11/03/2005 07:20:00 3.4 0.5 4.9 2.3 3.6 0.5 4.9 2.3 8 10 13 305 -2.9 0 -2.4 -3.1 11/03/2005 07:30:00 4.1 0.6 5.7 2.6 4.4 0.6 5.7 2.6 16 9 25 305 -3 0 -2.7 -3.1 11/03/2005 07:40:00 3.6 0.6 5.3 1.9 3.8 0.5 4.9 1.9 25 15 21 305 -3 0 -2.7 -3.1 11/03/2005 07:50:00 4.3 0.8 6.1 2.3 4.6 0.9 6.5 1.9 8 12 0 305 -3 0 -2.7 -3.1 11/03/2005 08:00:00 4.3 0.6 6.5 2.6 4.7 0.7 7.2 3 1 9 5 305 -3 0 -2.9 -3.1 11/03/2005 08:10:00 3.2 0.6 4.6 1.9 3.5 0.6 4.9 1.9 10 7 18 305 -3.1 0 -3.1 -3.3 11/03/2005 08:20:00 3.1 0.6 4.6 1.5 3.3 0.7 4.9 1.9 1 11 352 305 -3.2 0 -3.1 -3.3 11/03/2005 08:30:00 3.5 0.7 5.3 1.9 3.8 0.7 5.3 1.9 12 9 22 305 -3.2 0 -3.1 -3.3 11/03/2005 08:40:00 2.1 1 3.4 0.4 2.3 1 3.8 0.4 22 13 25 305 -3.2 0 -3.1 -3.3 11/03/2005 08:50:00 2 1.5 4.6 0.4 2.4 1.5 4.9 0.4 15 36 348 305 -3.3 0 -3.1 -3.3 11/03/2005 09:00:00 3.7 0.6 5.7 2.3 4 0.6 5.7 2.6 351 11 0 305 -3.3 0 -3.1 -3.3 11/03/2005 09:10:00 3.8 0.8 5.7 2.3 4.2 0.9 6.5 2.3 0 7 359 305 -3.3 0 -3.1 -3.3 11/03/2005 09:20:00 3.7 0.6 5.7 2.3 3.9 0.6 5.7 2.6 15 9 13 305 -3.3 0 -2.9 -3.3 11/03/2005 09:30:00 3.5 0.7 4.9 2.3 3.7 0.8 5.3 1.9 354 22 336 305 -3.3 0 -3.3 -3.3 11/03/2005 09:40:00 4 0.6 6.5 2.6 4.3 0.6 6.5 3 27 24 10 305 -3.3 0 -2.9 -3.6 11/03/2005 09:50:00 2.1 0.6 3.4 0.7 2.2 0.7 3.8 0.4 34 19 69 305 -3.4 0 -3.1 -3.6 11/03/2005 10:00:00 3.7 0.6 5.3 2.3 3.9 0.6 5.7 2.3 9 14 8 305 -3.3 0 -3.3 -3.6 11/03/2005 10:10:00 3.4 1.2 6.1 1.5 3.6 1.2 6.8 1.9 4 11 353 305 -3.5 0 -3.3 -3.6 11/03/2005 10:20:00 3 0.9 5.3 0.7 3.2 0.8 5.3 1.5 29 16 40 305 -3.5 0 -3.3 -3.8 11/03/2005 10:30:00 2.5 1.5 6.5 0.4 2.8 1.4 6.5 1.1 41 22 60 305 -3.6 0 -3.3 -3.8 11/03/2005 10:40:00 4.3 0.5 5.7 3 4.2 0.5 5.3 3 75 7 84 305 -3.6 0 -3.3 -3.8 11/03/2005 10:50:00 5.2 0.6 6.8 3.8 5.1 0.6 6.5 3.4 64 7 68 305 -3.5 0 -3.1 -3.8 11/03/2005 11:00:00 5.1 0.5 6.5 3.4 5.2 0.6 6.5 3.4 59 6 58 305 -3.4 0 -2.9 -3.6 11/03/2005 11:10:00 5 0.4 6.1 3.8 5.1 0.5 6.5 3.8 58 6 60 305 -3.3 0 -2.9 -3.6 11/03/2005 11:20:00 4.6 0.5 6.1 3.4 4.6 0.5 6.5 3.4 64 9 55 305 -3.3 0 -3.3 -3.6 11/03/2005 11:30:00 4.9 0.4 6.1 3.8 5 0.4 5.7 3.8 57 5 57 305 -3.3 0 -2.7 -3.3 11/03/2005 11:40:00 5 0.5 6.8 3.8 5 0.5 6.5 3.8 65 5 60 305 -3.2 0 -2.7 -3.3 11/03/2005 11:50:00 5.1 0.4 6.1 3.8 4.9 0.4 5.7 3.4 75 4 84 305 -3.2 0 -2.7 -3.3 11/03/2005 12:00:00 5.1 0.4 6.1 3.8 5 0.4 6.1 4.2 77 5 77 305 -3.2 0 -3.1 -3.3 11/03/2005 12:10:00 5.2 0.4 6.5 4.2 5.1 0.4 6.5 4.2 83 5 79 305 -3.1 0 -2.9 -3.1 11/03/2005 12:20:00 5.6 0.5 6.8 4.6 5.4 0.5 6.8 3.8 87 5 87 305 -3 0 -2.4 -3.1 11/03/2005 12:30:00 5.2 0.6 6.5 3.4 5 0.6 6.5 3.4 93 9 89 305 -2.9 0 -2.7 -3.1 11/03/2005 12:40:00 5 0.5 6.5 3.8 4.9 0.5 6.1 3.4 88 8 92 305 -2.8 0 -2.7 -2.9 11/03/2005 12:50:00 5.1 0.6 6.5 3.4 5.1 0.6 6.5 3.8 106 6 105 305 -2.8 0 -2.7 -3.1 11/03/2005 13:00:00 4.9 0.5 6.1 3.8 4.9 0.5 6.1 3.8 107 6 106 305 -2.8 0 -2.7 -2.9 11/03/2005 13:10:00 4.9 0.5 6.5 3.8 4.9 0.4 6.5 3.8 109 6 116 305 -2.8 0 -2.4 -2.9 11/03/2005 13:20:00 4.3 0.4 5.3 3 4.4 0.4 5.7 3.4 115 7 113 305 -2.8 0 -2.4 -2.9 11/03/2005 13:30:00 4.2 0.5 5.3 2.6 4.3 0.5 5.7 3 118 6 113 305 -2.8 0 -2.7 -2.9 11/03/2005 13:40:00 4.3 0.5 5.7 2.6 4.4 0.5 5.7 3 117 5 121 305 -2.8 0 -2.7 -2.9 11/03/2005 13:50:00 4.3 0.4 5.3 3.4 4.2 0.4 4.9 3 100 6 95 305 -2.8 0 -2.4 -2.9 11/03/2005 14:00:00 3.5 0.4 4.2 2.6 3.5 0.4 4.2 2.6 107 8 107 305 -2.8 0 -2.7 -2.9 11/03/2005 14:10:00 3.3 0.4 4.2 2.6 3.4 0.4 4.2 2.3 110 6 114 305 -2.7 0 -2.4 -2.7 11/03/2005 14:20:00 3.1 0.5 4.2 1.9 3.3 0.4 4.2 2.3 113 7 116 305 -2.7 0 -2.4 -2.7 11/03/2005 14:30:00 3 0.5 4.2 1.9 3.1 0.4 4.2 2.3 111 10 117 305 -2.6 0 -2 -2.7 11/03/2005 14:40:00 3.4 0.7 4.9 1.1 3.5 0.6 4.9 1.5 114 10 108 305 -2.7 0 -2.4 -2.7 11/03/2005 14:50:00 3.9 0.5 5.3 2.3 4 0.6 5.7 1.9 119 9 128 305 -2.7 0 -2.7 -2.7 11/03/2005 15:00:00 4.6 0.4 5.7 3 4.7 0.4 5.7 3.4 120 5 118 305 -2.7 0 -2.4 -2.7 11/03/2005 15:10:00 4.6 0.7 6.5 1.9 4.7 0.7 6.5 2.3 118 7 116 305 -2.6 0 -2.4 -2.7 11/03/2005 15:20:00 4.4 0.6 5.7 2.6 4.5 0.6 6.1 3 120 11 132 305 -2.5 0 -2.4 -2.7 11/03/2005 15:30:00 4.2 0.7 6.1 2.3 4.2 0.6 5.7 2.6 126 10 101 305 -2.6 0 -2.2 -2.7 11/03/2005 15:40:00 4 0.5 4.9 2.6 4 0.4 4.9 2.6 132 6 143 305 -2.6 0 -2.2 -2.7 11/03/2005 15:50:00 3.5 0.9 4.9 0.7 3.7 0.7 4.9 1.9 145 12 143 305 -2.7 0 -2.4 -2.7 11/03/2005 16:00:00 2.9 0.7 4.9 1.5 3.6 0.7 5.3 1.5 159 14 171 305 -2.7 0 -2.4 -2.7 11/03/2005 16:10:00 3.2 0.6 4.9 1.5 4.2 0.6 5.7 2.6 167 10 153 305 -2.9 0 -2.7 -3.1 11/03/2005 16:20:00 3.2 0.5 4.6 2.3 5.3 0.4 6.1 4.2 166 3 161 305 -3 0 -2.7 -3.1 11/03/2005 16:30:00 3.2 0.5 4.6 1.9 5.3 0.3 6.1 4.2 166 3 165 305 -3.1 0 -2.7 -3.3 11/03/2005 16:40:00 3.3 0.4 4.6 2.3 5.6 0.4 6.5 4.2 167 2 168 305 -3.1 0 -3.1 -3.1 11/03/2005 16:50:00 3.3 0.5 4.6 2.3 5.3 0.4 6.1 3.8 167 3 162 305 -3.1 0 -2.9 -3.3 11/03/2005 17:00:00 3.3 0.5 4.9 1.9 5.3 0.5 6.5 3.8 168 4 161 305 -3.1 0 -2.7 -3.3 11/03/2005 17:10:00 3.3 0.6 5.3 1.9 5.2 0.5 6.8 3.8 168 5 159 305 -3.1 0 -2.9 -3.1 11/03/2005 17:20:00 3.1 0.7 4.9 1.5 4.7 0.6 6.1 2.6 170 6 179 305 -3.2 0 -3.1 -3.3 11/03/2005 17:30:00 3.1 0.8 4.9 1.5 3.9 0.6 5.3 2.3 163 10 140 305 -3.3 0 -3.1 -3.3 11/03/2005 17:40:00 4 1 6.5 1.9 4.2 0.6 5.7 2.6 155 8 150 305 -3.4 0 -3.3 -3.6 11/03/2005 17:50:00 4.1 0.9 6.1 1.9 4.5 0.6 5.7 2.6 156 10 156 305 -3.5 0 -3.3 -3.6 11/03/2005 18:00:00 3.5 0.8 5.7 1.5 4.2 0.7 6.1 2.3 164 10 153 305 -3.5 0 -3.1 -3.6 11/03/2005 18:10:00 3.6 0.8 5.7 1.9 4.4 0.7 7.6 3 165 12 148 305 -3.4 0 -2.9 -3.6 11/03/2005 18:20:00 4.7 1 6.8 2.3 5.1 0.6 6.5 3.8 156 7 152 305 -3.5 0 -3.3 -3.8 11/03/2005 18:30:00 5.4 0.7 7.2 3.8 5.5 0.6 6.8 4.2 148 6 141 305 -3.6 0 -3.1 -3.8 11/03/2005 18:40:00 6.2 1 8.4 3.8 6.1 1 8.4 3.8 146 6 139 305 -3.5 0 -3.1 -3.8 11/03/2005 18:50:00 7.7 0.4 8.8 6.5 7.5 0.4 8.8 6.5 145 3 151 305 -3.4 0 -3.1 -3.6 11/03/2005 19:00:00 7.3 0.8 9.1 5.3 7.3 0.7 9.1 5.7 145 6 137 305 -3.5 0 -3.1 -3.8 11/03/2005 19:10:00 5.6 1 8 3.4 6.1 0.7 8.4 3.8 156 9 159 305 -3.4 0 -2.9 -3.6 11/03/2005 19:20:00 5.4 1 7.6 2.6 5.9 0.5 7.2 3.8 158 6 154 305 -3.3 0 -2.9 -3.6 11/03/2005 19:30:00 4 0.9 6.1 1.9 4.9 0.6 6.5 3 161 9 151 305 -3.3 0 -2.7 -3.6 11/03/2005 19:40:00 3.1 0.7 5.3 1.5 3.9 0.7 5.3 1.9 182 13 196 305 -3 0.2 -2 -3.3 11/03/2005 19:50:00 3.9 0.8 6.1 1.5 4.2 0.7 5.7 2.6 198 17 210 305 -2.7 0 -2.2 -2.7 11/03/2005 20:00:00 5.3 1.1 8.4 2.6 4.6 1 6.8 2.6 249 17 273 305 -2.4 0.2 -2 -2.7 11/03/2005 20:10:00 5.4 1 7.6 3.4 4.9 1 7.2 2.6 239 8 245 305 -2.2 0 -1.8 -2.2 11/03/2005 20:20:00 5.8 1 7.6 3.8 5.3 0.9 7.2 3 240 9 251 305 -2.2 0 -1.8 -2.2 11/03/2005 20:30:00 6.1 0.9 8.8 3.8 5.4 1 8 3 245 8 244 305 -2 0 -2 -2 11/03/2005 20:40:00 7.2 0.7 9.1 5.3 6.1 0.8 8.4 3.8 251 7 259 305 -2 0 -1.8 -2 11/03/2005 20:50:00 7 0.7 8.8 4.9 5.8 0.8 8 3.8 255 7 259 305 -2 0 -1.8 -2 11/03/2005 21:00:00 6.3 1 8.4 3.4 4.9 0.8 7.2 3 259 8 262 305 -2.1 0 -2 -2.2 11/03/2005 21:10:00 5.7 0.9 7.6 3 4.8 0.9 6.8 2.6 257 8 259 305 -2.2 0 -2 -2.2 11/03/2005 21:20:00 6.6 0.9 8.8 4.2 5 0.9 7.2 2.6 269 8 275 305 -2.2 0 -2 -2.4 11/03/2005 21:30:00 6.2 0.7 7.6 4.6 5.1 0.9 7.2 3 261 12 252 305 -2.3 0 -2.2 -2.4 11/03/2005 21:40:00 6.9 1 9.1 4.2 5.4 1 7.6 3 270 9 276 305 -2.2 0 -2 -2.4 11/03/2005 21:50:00 6.8 0.9 8.8 4.9 5.5 0.9 7.6 3.4 276 8 281 305 -2.2 0 -2 -2.4 11/03/2005 22:00:00 7 0.8 8.8 4.9 5.3 0.9 7.6 3.4 270 8 269 305 -2.4 0 -2 -2.4 11/03/2005 22:10:00 6.3 1 8.4 3 5.3 1 7.6 2.6 278 11 286 305 -2.3 0 -2.2 -2.4 11/03/2005 22:20:00 6.4 0.8 8.8 3.8 5.3 1.1 8 2.6 278 11 288 305 -2.3 0 -2 -2.4 11/03/2005 22:30:00 6.6 0.7 8.4 4.9 5.7 0.7 7.2 3.8 283 7 293 305 -2.3 0 -2 -2.4 11/03/2005 22:40:00 7 0.8 8.8 4.9 6.3 0.8 8.4 4.2 291 6 297 305 -2.3 0 -1.8 -2.4 11/03/2005 22:50:00 7.3 0.7 9.1 5.7 6.9 0.7 9.1 4.9 296 9 291 305 -2.2 0 -2.2 -2.4 11/03/2005 23:00:00 6.6 0.5 8 5.3 6.4 0.5 7.6 4.9 298 11 298 305 -2.3 0 -2.2 -2.4 11/03/2005 23:10:00 6.4 0.6 8 4.9 6.3 0.5 7.6 4.9 303 8 284 305 -2.3 0 -2.2 -2.4 11/03/2005 23:20:00 6.4 0.5 8 4.9 6.4 0.6 7.6 4.6 304 9 294 305 -2.3 0 -2.2 -2.4 11/03/2005 23:30:00 6.2 0.6 7.6 4.6 6.3 0.6 7.6 4.9 308 8 302 305 -2.2 0 -1.8 -2.4 11/03/2005 23:40:00 6.1 0.5 8 4.9 6.3 0.5 7.6 4.9 314 8 298 305 -2.2 0 -2 -2.4 11/03/2005 23:50:00 5.7 0.6 7.2 4.2 6 0.6 7.2 4.6 318 7 312 305 -2.2 0 -2 -2.4 11/04/2005 00:00:00 5.8 0.5 7.2 4.6 5.9 0.5 7.6 4.6 312 7 316 305 -2.3 0 -2 -2.4 11/04/2005 00:10:00 5.4 0.6 7.6 3.8 5.7 0.7 7.6 4.2 312 6 324 305 -2.4 0 -2 -2.7 11/04/2005 00:20:00 5.6 0.6 6.8 3.4 5.8 0.6 6.8 3.8 308 6 309 305 -2.6 0 -2 -2.7 11/04/2005 00:30:00 5.3 0.5 6.8 3.8 5.5 0.5 6.8 4.2 315 7 300 305 -2.6 0 -2 -2.7 11/04/2005 00:40:00 5.3 0.5 6.5 4.2 5.6 0.5 6.8 4.2 315 6 305 305 -2.5 0 -2.2 -2.7 11/04/2005 00:50:00 5.7 0.5 6.8 4.2 6 0.6 7.2 4.6 322 5 325 305 -2.5 0 -2 -2.7 11/04/2005 01:00:00 6.1 0.7 7.6 4.6 6.3 0.7 8 4.6 318 6 305 305 -2.5 0 -2 -2.7 11/04/2005 01:10:00 6.1 0.6 8 4.9 6.3 0.6 8 5.3 315 6 319 305 -2.5 0 -2 -2.7 11/04/2005 01:20:00 5.7 0.6 7.6 4.2 5.9 0.7 8 4.2 316 7 307 305 -2.6 0.1 -2.2 -2.7 11/04/2005 01:30:00 5.5 0.5 6.8 4.2 5.8 0.5 7.2 4.6 321 6 318 305 -2.6 0 -2.4 -2.7 11/04/2005 01:40:00 5.4 0.6 7.2 4.2 5.6 0.6 7.2 4.2 317 7 313 305 -2.7 0 -2.7 -2.7 11/04/2005 01:50:00 5.2 0.5 6.5 4.2 5.5 0.4 6.5 4.6 314 7 303 305 -2.7 0 -2.2 -2.7 11/04/2005 02:00:00 4.8 0.5 5.7 3.8 5.1 0.6 6.1 3.8 318 6 327 305 -2.7 0 -2.2 -2.7 11/04/2005 02:10:00 4.3 0.5 5.7 3 4.3 0.6 5.7 3 316 7 329 305 -2.7 0 -2.4 -2.9 11/04/2005 02:20:00 4.3 0.6 5.7 3.4 4.6 0.6 5.7 3.8 321 7 313 305 -2.8 0 -2.7 -2.9 11/04/2005 02:30:00 4.3 0.6 5.7 3 4.6 0.6 6.1 3 318 8 324 305 -2.8 0 -2.4 -2.9 11/04/2005 02:40:00 3.7 0.5 5.3 2.3 3.9 0.5 5.7 2.6 321 8 305 305 -2.8 0 -2.4 -3.1 11/04/2005 02:50:00 4.1 0.5 4.9 3 4.3 0.5 5.3 3 321 7 327 305 -2.8 0 -2.4 -3.1 11/04/2005 03:00:00 3.8 0.4 4.9 3 3.8 0.4 4.6 3 312 7 316 305 -2.8 0 -2.7 -3.1 11/04/2005 03:10:00 4 0.5 5.3 2.6 4.1 0.5 5.3 3 313 7 312 305 -3 0 -2.7 -3.3 11/04/2005 03:20:00 3.5 0.8 5.3 1.9 3.6 0.8 5.3 2.3 322 12 305 305 -3 0 -2.9 -3.1 11/04/2005 03:30:00 3.9 0.5 4.9 2.3 4.1 0.5 5.3 2.3 318 8 331 305 -3 0 -2.9 -3.1 11/04/2005 03:40:00 4.1 0.4 5.3 3 4.2 0.4 5.3 3 310 9 303 305 -3.1 0 -2.9 -3.3 11/04/2005 03:50:00 3.9 0.6 5.3 2.6 4.1 0.6 5.3 2.6 308 7 322 305 -3.3 0 -3.1 -3.3 11/04/2005 04:00:00 4.1 0.5 5.7 2.6 4.2 0.6 5.7 2.6 311 7 319 305 -3.1 0 -2.9 -3.3 11/04/2005 04:10:00 3.9 0.6 5.7 3 3.9 0.6 5.7 2.6 303 6 313 305 -3.1 0.1 -2.9 -3.3 11/04/2005 04:20:00 3.4 0.4 4.2 2.3 3.6 0.5 4.9 2.3 312 7 311 305 -3.2 0.1 -3.1 -3.3 11/04/2005 04:30:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 319 6 322 305 -3.1 0 -2.4 -3.3 11/04/2005 04:40:00 2.8 0.5 3.8 1.5 2.8 0.5 3.8 1.5 316 7 319 305 -3 0 -2.7 -3.1 11/04/2005 04:50:00 2.4 0.5 3.4 1.1 2.5 0.5 3.4 1.5 327 11 329 305 -3 0 -2.7 -3.1 11/04/2005 05:00:00 1.7 0.5 3 0.7 2 0.4 3.4 1.1 335 13 337 305 -2.8 0 -2.2 -3.1 11/04/2005 05:10:00 2.5 0.5 3.4 0.7 2.6 0.5 3.8 1.5 327 8 333 305 -2.9 0.1 -2.4 -3.1 11/04/2005 05:20:00 1.9 0.5 3.4 0.7 2.1 0.4 3 1.5 322 7 330 305 -3.2 0 -2.7 -3.3 11/04/2005 05:30:00 1.3 0.5 2.3 0.4 1.7 0.4 2.6 1.1 313 8 316 305 -3.4 0.2 -3.1 -3.8 11/04/2005 05:40:00 0.9 0.6 2.3 0.4 1.4 0.4 2.3 0.7 314 9 305 305 -3.9 0 -3.8 -4 11/04/2005 05:50:00 1.5 0.5 2.6 0.4 1.5 0.4 2.3 0.4 347 8 341 305 -4.1 0 -3.8 -4.2 11/04/2005 06:00:00 1.1 0.6 2.3 0.4 1.5 0.4 2.3 0.7 340 10 339 305 -4.1 0 -3.6 -4.2 11/04/2005 06:10:00 1.1 0.7 2.6 0.4 1.4 0.8 2.6 0.4 344 5 339 305 -4 0 -3.8 -4 11/04/2005 06:20:00 0.8 0.6 2.3 0.4 1.1 0.8 2.6 0.4 338 4 334 305 -3.7 0.1 -3.3 -4 11/04/2005 06:30:00 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 333 10 312 305 -3.5 0 -3.3 -3.8 11/04/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 340 0 305 305 -3.6 0 -3.3 -3.8 11/04/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 340 0 305 305 -3.4 0 -3.3 -3.8 11/04/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 340 0 305 305 -3.4 0 -3.3 -3.6 11/04/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 340 0 305 305 -3.3 0 -3.1 -3.3 11/04/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 340 0 305 305 -3.4 0 -3.3 -3.6 11/04/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 340 0 305 305 -3.5 0 -3.3 -3.8 11/04/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 340 0 305 305 -3.6 0 -3.3 -3.8 11/04/2005 07:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 341 11 305 305 -3.7 0 -3.3 -3.8 11/04/2005 08:00:00 0.4 0 0.4 0.4 0.5 0.2 0.7 0.4 83 0 305 305 -3.5 0 -3.3 -3.8 11/04/2005 08:10:00 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 83 1 305 305 -3.4 0 -2.9 -3.6 11/04/2005 08:20:00 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 84 0 305 305 -3.4 0 -2.9 -3.6 11/04/2005 08:30:00 0.4 0 0.4 0.4 0.9 0.2 1.1 0.4 84 0 305 305 -3.5 0 -3.3 -3.8 11/04/2005 08:40:00 0.4 0 0.4 0.4 1 0.3 1.5 0.4 84 0 305 305 -3.5 0 -3.1 -3.8 11/04/2005 08:50:00 0.4 0.2 1.1 0.4 1.1 0.3 1.9 0.4 88 6 112 305 -3.3 0 -2.7 -3.6 11/04/2005 09:00:00 0.4 0.1 1.1 0.4 1.1 0.2 1.9 0.4 74 15 96 305 -3.1 0 -2.9 -3.3 11/04/2005 09:10:00 0.7 0.4 1.9 0.4 1.3 0.3 2.3 0.7 52 3 56 305 -2.7 0.1 -2 -3.1 11/04/2005 09:20:00 0.4 0.2 1.5 0.4 0.9 0.3 1.5 0.4 54 22 44 305 -2.6 0 -2.2 -2.7 11/04/2005 09:30:00 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 101 9 305 305 -2.8 0 -2.2 -2.9 11/04/2005 09:40:00 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 115 4 305 305 -2.6 0.1 -2 -2.7 11/04/2005 09:50:00 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 111 16 116 305 -2.6 0 -2 -2.7 11/04/2005 10:00:00 0.5 0.3 1.5 0.4 0.7 0.5 1.9 0.4 108 29 100 305 -2.6 0 -2 -2.7 11/04/2005 10:10:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 128 33 101 305 -2.7 0 -2 -2.7 11/04/2005 10:20:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 112 38 84 305 -2.7 0 -2 -2.7 11/04/2005 10:30:00 0.6 0.3 1.5 0.4 1.3 0.2 1.9 0.7 88 6 84 305 -2.8 0 -2.2 -2.9 11/04/2005 10:40:00 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 54 32 72 305 -2.7 0 -2.2 -2.7 11/04/2005 10:50:00 1.3 0.8 2.6 0.4 1.6 0.6 3 0.4 90 24 104 305 -2.6 0 -2.4 -2.7 11/04/2005 11:00:00 2.1 0.6 3.4 0.4 2.3 0.6 3.8 1.1 114 8 124 305 -2.6 0 -2.4 -2.7 11/04/2005 11:10:00 3 0.6 4.6 1.9 3.2 0.6 4.6 1.5 123 6 119 305 -2.5 0 -2.4 -2.7 11/04/2005 11:20:00 3.8 0.3 4.6 3 3.9 0.3 4.6 3 116 3 114 305 -2.5 0 -2.4 -2.7 11/04/2005 11:30:00 3.8 0.3 4.6 3 3.9 0.3 4.6 3 115 3 118 305 -2.6 0 -2.4 -2.7 11/04/2005 11:40:00 4.4 0.3 4.9 3.4 4.4 0.3 4.9 3.8 115 3 116 305 -2.5 0 -2.4 -2.7 11/04/2005 11:50:00 4.1 0.3 4.6 3.4 4.3 0.3 4.9 3.4 120 3 120 305 -2.4 0 -2.2 -2.4 11/04/2005 12:00:00 3.9 0.5 4.9 2.3 4 0.4 4.9 2.6 120 6 124 305 -2.2 0 -2 -2.4 11/04/2005 12:10:00 3.2 0.5 4.6 1.9 3.2 0.5 4.6 2.3 123 8 114 305 -2.2 0 -2 -2.2 11/04/2005 12:20:00 3.8 0.4 4.6 2.6 3.9 0.4 4.6 3 118 4 119 305 -2.1 0 -2 -2.2 11/04/2005 12:30:00 3.4 0.6 4.6 1.9 3.5 0.5 4.6 2.3 111 6 114 305 -2.1 0 -2 -2.2 11/04/2005 12:40:00 3.3 0.6 4.6 1.9 3.3 0.5 4.6 2.3 111 5 116 305 -2 0 -2 -2.2 11/04/2005 12:50:00 4 0.4 4.6 3 4 0.3 4.6 3 114 3 112 305 -2 0 -1.8 -2 11/04/2005 13:00:00 3.8 0.4 4.6 2.6 3.8 0.3 4.6 3 109 4 108 305 -1.9 0 -1.5 -2 11/04/2005 13:10:00 3.9 0.4 4.9 3 3.9 0.4 4.6 2.6 106 4 102 305 -1.8 0 -1.3 -2 11/04/2005 13:20:00 4 0.6 5.3 2.6 4 0.6 4.9 2.6 101 5 90 305 -1.7 0 -1.3 -1.8 11/04/2005 13:30:00 4 0.4 4.9 3 3.9 0.4 4.6 3 99 5 99 305 -1.6 0 -1.1 -1.8 11/04/2005 13:40:00 4.3 0.4 5.3 3 4.3 0.4 5.3 3 102 5 97 305 -1.6 0 -1.1 -1.8 11/04/2005 13:50:00 4.9 0.4 6.1 3 4.8 0.4 6.1 3.8 106 5 109 305 -1.5 0 -1.3 -1.8 11/04/2005 14:00:00 4.9 0.4 5.7 3.8 4.8 0.5 5.7 3.4 105 6 105 305 -1.5 0 -1.1 -1.8 11/04/2005 14:10:00 5.3 0.4 6.1 4.2 5.2 0.4 6.1 4.2 110 5 110 305 -1.5 0 -1.1 -1.8 11/04/2005 14:20:00 4.9 0.5 6.1 3.8 4.9 0.5 6.1 3.8 111 6 105 305 -1.5 0 -1.1 -1.8 11/04/2005 14:30:00 4.3 0.5 5.7 3 4.2 0.5 5.3 3 103 8 96 305 -1.5 0 -1.1 -1.8 11/04/2005 14:40:00 4 0.5 5.3 3 3.9 0.4 4.9 3 106 8 113 305 -1.5 0 -1.1 -1.8 11/04/2005 14:50:00 4.1 0.5 5.7 2.3 4 0.5 5.3 2.6 107 7 100 305 -1.4 0 -1.1 -1.5 11/04/2005 15:00:00 3.9 0.6 5.3 2.3 3.8 0.5 5.3 2.6 102 8 94 305 -1.4 0 -1.1 -1.5 11/04/2005 15:10:00 3.4 0.8 6.1 1.5 3.3 0.7 5.3 1.9 98 16 103 305 -1.2 0 -1.1 -1.3 11/04/2005 15:20:00 2.5 1 4.2 0.4 2.7 0.7 4.2 0.7 90 17 89 305 -1.1 0 -1.1 -1.3 11/04/2005 15:30:00 3.1 1 5.3 0.4 3.2 0.7 4.9 1.9 91 21 99 305 -1 0 -0.8 -1.1 11/04/2005 15:40:00 3.7 1 5.7 1.1 3.7 0.8 5.7 1.5 94 13 109 305 -0.8 0 -0.6 -1.1 11/04/2005 15:50:00 4.4 0.6 6.1 2.6 4.2 0.6 5.7 2.6 99 9 94 305 -0.8 0 -0.6 -1.1 11/04/2005 16:00:00 5.2 0.7 6.5 3 5 0.8 7.2 3.4 104 8 113 305 -0.8 0 -0.6 -0.8 11/04/2005 16:10:00 4.8 0.6 6.5 3.4 4.7 0.6 6.1 3.4 101 7 110 305 -0.8 0 -0.6 -1.1 11/04/2005 16:20:00 4.5 0.7 6.5 2.3 4.3 0.7 6.5 2.3 103 9 105 305 -0.8 0 -0.6 -1.1 11/04/2005 16:30:00 4.9 0.5 6.5 3.4 4.7 0.5 6.1 3.4 100 8 110 305 -1 0 -0.8 -1.1 11/04/2005 16:40:00 5.5 0.4 6.5 4.6 5.2 0.4 6.1 4.2 99 4 99 305 -1.1 0 -0.6 -1.3 11/04/2005 16:50:00 5.8 0.5 6.8 4.2 5.4 0.5 6.5 3.8 101 4 105 305 -1.1 0 -1.1 -1.3 11/04/2005 17:00:00 6 0.4 6.8 4.9 5.7 0.4 6.8 4.6 101 5 96 305 -1.1 0 -1.1 -1.3 11/04/2005 17:10:00 5.9 0.6 7.2 4.2 5.7 0.5 6.8 4.6 107 6 102 305 -1.1 0 -1.1 -1.3 11/04/2005 17:20:00 6.1 0.6 7.6 4.6 5.9 0.6 7.2 4.6 107 6 107 305 -1.2 0 -1.1 -1.3 11/04/2005 17:30:00 5.8 0.8 7.2 3.8 5.6 0.8 6.8 3.4 109 7 108 305 -1.4 0 -1.1 -1.5 11/04/2005 17:40:00 6 0.9 8 3.8 5.8 0.8 8 3.4 111 7 112 305 -1.4 0 -0.8 -1.5 11/04/2005 17:50:00 6.2 0.7 7.6 4.2 6.2 0.7 8 4.2 115 6 112 305 -1.6 0 -1.3 -1.8 11/04/2005 18:00:00 6.8 0.6 8.4 4.6 6.7 0.6 7.6 5.3 118 4 119 305 -1.6 0 -1.3 -1.8 11/04/2005 18:10:00 6.7 0.6 8 5.3 6.7 0.6 8 4.9 119 5 117 305 -1.6 0 -1.1 -1.8 11/04/2005 18:20:00 6.1 0.8 8 3.8 6.1 0.9 8 3.4 121 5 120 305 -1.6 0 -1.1 -1.8 11/04/2005 18:30:00 5.5 1.1 8 3 5.5 1.2 8 3 126 6 129 305 -1.6 0 -1.1 -1.8 11/04/2005 18:40:00 5.9 0.8 8 3.8 5.9 0.7 7.6 3.8 126 6 124 305 -1.5 0 -1.1 -1.8 11/04/2005 18:50:00 5.4 1.2 8 3.4 5.3 1.2 8 3.4 123 6 125 305 -1.4 0 -1.1 -1.5 11/04/2005 19:00:00 6.2 1 8 3.8 6.1 1 8 3.4 128 7 133 305 -1.4 0 -1.1 -1.5 11/04/2005 19:10:00 6 1 8 2.6 6 1 8 3 126 6 132 305 -1.4 0 -1.1 -1.5 11/04/2005 19:20:00 5.8 1 8 3 5.7 1 8 3.4 126 7 119 305 -1.3 0 -0.8 -1.3 11/04/2005 19:30:00 5.6 0.6 6.8 4.2 5.7 0.6 6.8 4.2 126 7 123 305 -1.2 0 -1.1 -1.3 11/04/2005 19:40:00 5.5 0.7 6.8 3.4 5.5 0.7 7.2 3.8 130 7 130 305 -1.2 0 -1.1 -1.3 11/04/2005 19:50:00 5.2 0.7 6.5 3.4 5.3 0.7 6.5 3.4 127 6 135 305 -1.1 0 -1.1 -1.3 11/04/2005 20:00:00 4.9 0.5 6.1 3.4 5 0.5 6.1 3.4 130 6 123 305 -1.2 0 -1.1 -1.3 11/04/2005 20:10:00 5.2 0.5 6.5 3.8 5.3 0.5 6.5 3.8 132 6 136 305 -1.3 0 -0.6 -1.5 11/04/2005 20:20:00 5.4 0.6 6.8 3.8 5.4 0.7 6.8 3.8 130 4 136 305 -1.4 0 -1.3 -1.5 11/04/2005 20:30:00 5.5 0.4 6.5 4.2 5.7 0.4 6.8 4.6 132 3 135 305 -1.6 0.1 -1.3 -2 11/04/2005 20:40:00 5.3 0.4 6.8 4.2 5.5 0.4 6.8 3.8 134 2 135 305 -1.9 0 -1.8 -2 11/04/2005 20:50:00 4.6 0.7 5.7 2.6 4.9 0.6 6.1 3 129 6 126 305 -1.8 0 -1.8 -2 11/04/2005 21:00:00 3.1 0.8 4.6 0.4 3.2 0.8 4.6 0.7 204 64 136 305 -2.4 0.7 -1.5 -3.8 11/04/2005 21:10:00 1.9 0.5 3 0.4 2.1 0.7 3.8 0.4 198 30 221 305 -3.5 0.4 -2.7 -4 11/04/2005 21:20:00 1.2 0.7 2.6 0.4 1.5 0.5 2.6 0.4 226 43 246 305 -2.7 0 -2.4 -2.7 11/04/2005 21:30:00 5 1.1 6.5 1.5 5.1 1.1 6.8 1.9 141 8 143 305 -2.7 0 -2.7 -2.9 11/04/2005 21:40:00 6.9 0.6 8.4 5.3 6.7 0.6 7.6 4.9 146 3 151 305 -2.8 0 -2.4 -3.1 11/04/2005 21:50:00 7.6 0.3 8.4 6.8 7.3 0.3 8 6.5 148 2 150 305 -3 0 -2.9 -3.1 11/04/2005 22:00:00 7.7 0.4 8.4 6.5 7.2 0.3 8 6.5 150 2 147 305 -3.2 0 -3.1 -3.3 11/04/2005 22:10:00 7.5 0.5 8.4 5.7 7.3 0.3 8 6.5 152 3 150 305 -3.3 0 -2.7 -3.3 11/04/2005 22:20:00 8 0.4 9.1 6.5 7.7 0.3 8.4 6.8 149 2 150 305 -3.1 0 -2.7 -3.3 11/04/2005 22:30:00 7.5 0.8 8.8 4.6 7.7 0.3 8.4 6.5 153 3 152 305 -3.1 0.1 -2.7 -3.3 11/04/2005 22:40:00 7.8 0.5 8.8 6.1 7.8 0.3 8.4 6.8 152 3 151 305 -3.3 0 -3.1 -3.3 11/04/2005 22:50:00 7.2 1 8.8 4.2 7.6 0.3 8.4 6.5 154 5 155 305 -3.4 0 -3.1 -3.6 11/04/2005 23:00:00 5.1 0.8 7.2 3 6.9 0.4 7.6 5.3 162 6 163 305 -3.4 0 -3.3 -3.6 11/04/2005 23:10:00 4.3 0.7 6.1 2.3 6.5 0.5 8 4.9 168 7 183 305 -2.7 0.3 -2.2 -3.3 11/04/2005 23:20:00 3.8 0.7 6.8 2.3 5.6 0.4 6.8 4.2 171 6 186 305 -2.2 0 -1.8 -2.4 11/04/2005 23:30:00 3 0.5 4.6 1.9 4.9 0.3 5.7 4.2 172 5 180 305 -2.4 0.2 -2 -2.7 11/04/2005 23:40:00 3.6 0.7 5.3 2.3 4.6 0.4 5.7 3.4 180 6 191 305 -2.4 0.3 -1.8 -2.7 11/04/2005 23:50:00 4.5 0.7 6.5 3 4.9 0.6 6.8 3.8 186 5 194 305 -1.8 0 -1.3 -2 11/05/2005 00:00:00 4.9 0.6 6.8 3.4 5 0.5 6.5 3.4 196 7 190 305 -1.4 0 -1.1 -1.8 11/05/2005 00:10:00 4.4 0.5 5.7 3 4.5 0.5 5.7 2.3 205 10 220 305 -1.1 0.1 -0.4 -1.3 11/05/2005 00:20:00 5.2 1.6 9.1 2.3 4.8 1.3 8.4 2.3 220 16 242 305 -0.7 0.3 0.1 -1.1 11/05/2005 00:30:00 7.4 1 9.1 4.9 6.5 1 8.4 4.2 236 5 234 305 -0.1 0 0.1 -0.4 11/05/2005 00:40:00 7.1 1 9.1 4.9 6.2 1 8.4 3.8 232 6 227 305 -0.1 0 0.1 -0.4 11/05/2005 00:50:00 8.2 0.6 9.1 6.1 7.3 0.7 9.1 5.7 226 4 227 305 0 0 0.3 -0.1 11/05/2005 01:00:00 7.3 0.7 9.1 5.3 6.6 0.8 8.8 4.6 220 4 225 305 -0.3 0 0.3 -0.4 11/05/2005 01:10:00 7.3 0.6 8.8 4.9 6.7 0.7 8.4 4.6 212 6 215 305 -0.4 0 -0.1 -0.4 11/05/2005 01:20:00 6.4 0.6 7.6 4.2 6.2 0.6 7.2 4.2 195 8 200 305 -0.6 0.1 -0.4 -1.1 11/05/2005 01:30:00 6.9 0.5 7.6 4.6 7 0.4 8 6.1 188 3 190 305 -0.8 0 -0.6 -1.1 11/05/2005 01:40:00 7.2 0.4 8.4 5.7 7.2 0.3 8 6.5 189 3 188 305 -0.9 0 -0.6 -1.1 11/05/2005 01:50:00 7.3 0.3 8 6.5 7.2 0.3 8 5.7 190 2 189 305 -1.1 0 -0.8 -1.1 11/05/2005 02:00:00 7.8 0.4 8.8 6.5 7.8 0.4 8.8 6.5 186 2 187 305 -1.2 0 -1.1 -1.3 11/05/2005 02:10:00 8 0.5 8.8 6.1 8.1 0.4 9.1 6.8 183 3 183 305 -1.1 0 -0.8 -1.3 11/05/2005 02:20:00 8.1 0.5 9.1 5.7 8.2 0.4 9.1 6.8 184 2 186 305 -0.8 0 -0.6 -1.1 11/05/2005 02:30:00 7.2 1 9.1 3.8 7.9 0.6 9.1 6.1 180 4 179 305 -0.7 0 -0.4 -1.1 11/05/2005 02:40:00 8.2 0.7 9.5 5.7 8.5 0.5 9.5 6.1 184 3 184 305 -0.6 0 -0.4 -0.8 11/05/2005 02:50:00 6.2 1.3 9.1 3.4 7.6 0.8 9.5 5.3 177 7 184 305 -0.5 0.1 -0.4 -1.1 11/05/2005 03:00:00 6.2 1.1 9.1 3.8 8.2 0.6 9.5 6.1 163 5 159 305 -1.5 0.2 -0.8 -1.8 11/05/2005 03:10:00 8.4 1 10.7 5.3 8.9 0.6 10.3 6.5 156 5 159 305 -1.9 0.3 -1.8 -2.9 11/05/2005 03:20:00 8.2 0.7 9.5 5.3 8.1 0.6 9.9 6.8 155 4 153 305 -3.3 0.1 -2.7 -3.6 11/05/2005 03:30:00 7.7 1 9.9 4.9 9.4 0.4 10.7 8 160 4 158 305 -2.3 0.4 -1.8 -3.1 11/05/2005 03:40:00 7.7 1.2 11.1 4.9 9.7 0.5 11.1 8.4 161 4 151 305 -1.9 0 -1.8 -2 11/05/2005 03:50:00 10.3 0.8 11.8 7.6 10 0.7 11.5 8 153 5 153 305 -2.1 0.2 -1.8 -2.4 11/05/2005 04:00:00 9.8 1 12.2 6.1 10 0.8 12.2 7.6 155 5 147 305 -2.3 0.1 -1.5 -2.7 11/05/2005 04:10:00 9.8 1.1 12.2 5.3 9.9 0.8 12.2 7.6 155 5 151 305 -2 0 -1.8 -2.2 11/05/2005 04:20:00 9.4 1.2 11.8 5.3 10.3 0.8 11.8 7.2 157 6 147 305 -2 0 -1.8 -2.2 11/05/2005 04:30:00 7.7 1.3 11.1 4.6 9.9 0.6 11.8 8 162 6 154 305 -2.2 0 -2 -2.4 11/05/2005 04:40:00 7.5 1.3 11.5 5.3 9.8 0.7 12.6 8 162 6 171 305 -2.3 0.1 -1.8 -2.4 11/05/2005 04:50:00 7.5 1.2 11.5 4.9 10.1 0.8 12.6 8 165 6 161 305 -2.1 0 -1.8 -2.2 11/05/2005 05:00:00 9.6 1.2 12.2 6.5 10.9 0.7 12.6 9.1 157 5 153 305 -1.6 0 -1.3 -2 11/05/2005 05:10:00 8 1.3 11.8 5.3 10.2 0.7 11.8 8.4 161 6 155 305 -1.6 0 -1.3 -1.8 11/05/2005 05:20:00 7.8 1.1 11.1 5.3 10.9 1 13.7 8.8 168 6 163 305 -1.1 0.2 -0.6 -1.5 11/05/2005 05:30:00 8.3 1.2 12.2 5.7 11.1 0.9 14.5 8.8 165 6 177 305 -1 0.1 -0.6 -1.1 11/05/2005 05:40:00 8.7 1.2 12.2 6.1 11 1.3 14.1 7.2 165 6 158 305 -0.8 0 -0.6 -1.1 11/05/2005 05:50:00 10 1.6 14.1 6.1 11.4 1 14.1 8.8 161 6 155 305 -0.7 0.1 -0.4 -1.1 11/05/2005 06:00:00 9.8 1.1 14.1 6.8 12.7 1.3 16.8 9.1 167 6 159 305 -0.3 0.2 0.3 -0.6 11/05/2005 06:10:00 10.2 1 13.3 7.2 13.6 1.1 16.8 9.9 170 5 165 305 0.4 0.1 0.8 0.1 11/05/2005 06:20:00 10.5 1 13.7 8.4 14.4 1 16.8 11.5 170 4 175 305 0.5 0 0.8 0.3 11/05/2005 06:30:00 10.9 1.2 14.5 8 13.7 1 16.8 10.3 171 5 174 305 0.5 0 1.3 0.3 11/05/2005 06:40:00 10 1.7 14.1 6.8 11.8 1.2 15.3 9.1 174 6 176 305 0.5 0 0.6 0.3 11/05/2005 06:50:00 10.7 1.6 14.9 7.6 11.7 1.1 14.9 8.4 175 6 177 305 0.6 0 0.8 0.6 11/05/2005 07:00:00 11.7 1.3 14.9 8.4 12.1 1.2 15.3 8.4 180 6 177 305 0.6 0 0.8 0.6 11/05/2005 07:10:00 12.3 0.8 14.5 10.3 12.2 1 14.5 9.5 189 4 190 305 0.6 0 1 0.6 11/05/2005 07:20:00 11.6 0.7 13.7 9.9 11.4 0.8 14.1 9.1 194 3 194 305 0.7 0 1.3 0.6 11/05/2005 07:30:00 12.3 0.8 15.3 10.7 11.7 0.8 14.1 9.1 194 3 192 305 1 0 1.5 0.8 11/05/2005 07:40:00 12.4 0.7 14.9 10.7 12 0.8 14.5 9.5 201 4 208 305 1.3 0.1 2 1 11/05/2005 07:50:00 12.3 0.8 14.1 9.9 11.4 1 13.7 8.8 211 5 203 305 1.6 0 2.2 1.5 11/05/2005 08:00:00 11.6 0.8 14.1 9.1 11 0.8 13 8.8 217 4 218 305 1.7 0.1 2.2 1.5 11/05/2005 08:10:00 11.5 1.1 14.1 8 10.3 1.1 13.7 8 222 6 220 305 1.8 0.2 2.2 1.5 11/05/2005 08:20:00 11.8 1 14.5 8.8 10.7 1.1 13.3 8 223 5 224 305 1.8 0.1 2.5 1.5 11/05/2005 08:30:00 11.8 1 14.5 8.8 10.7 1.1 14.1 7.6 226 4 224 305 1.8 0.1 2.5 1.5 11/05/2005 08:40:00 10.9 1 13.3 7.6 9.8 1 12.6 7.2 224 5 227 305 1.7 0.1 2.2 1.5 11/05/2005 08:50:00 11 1.7 14.5 7.6 9.6 2.1 14.1 5.3 251 17 228 305 1.4 0.3 2.2 1 11/05/2005 09:00:00 8.4 1.2 11.5 4.9 6.4 1.1 9.5 3 268 7 267 305 1.1 0.1 1.5 1 11/05/2005 09:10:00 8.3 1.1 10.7 5.3 6.9 1.1 10.3 4.6 273 6 272 305 1.2 0.1 1.7 1 11/05/2005 09:20:00 8.2 1.9 13 4.6 6.8 2.2 12.2 3 272 11 296 305 1.3 0 1.7 1 11/05/2005 09:30:00 10.3 1 12.2 7.6 9.7 1 11.8 7.2 291 6 292 305 1 0.1 1.5 0.6 11/05/2005 09:40:00 9.7 1.2 12.2 7.2 9 1.2 11.8 5.7 286 7 278 305 0.6 0.1 1 0.6 11/05/2005 09:50:00 10.5 1.1 12.6 7.2 10.2 1.2 12.6 6.5 294 12 294 305 0.4 0 1 0.3 11/05/2005 10:00:00 10.2 1.3 13.3 7.2 9.7 1.4 13 6.8 290 6 283 305 0.3 0 0.8 0.1 11/05/2005 10:10:00 11.1 1.1 13.3 8 10.4 1.2 13.3 7.6 287 6 284 305 0.3 0 0.6 0.1 11/05/2005 10:20:00 10.9 1.3 13.3 7.2 10.2 1.4 12.6 6.1 285 11 280 305 0.2 0 0.6 0.1 11/05/2005 10:30:00 10.6 1.2 13 6.8 9.9 1.3 12.2 6.1 285 7 285 305 0.1 0 0.6 0.1 11/05/2005 10:40:00 10.1 1.2 13 6.5 9.3 1.3 12.2 6.1 285 7 283 305 0 0 0.6 -0.1 11/05/2005 10:50:00 10.5 1 12.6 7.6 9.9 1 12.6 7.2 288 6 288 305 -0.2 0 0.3 -0.4 11/05/2005 11:00:00 10 1.3 13 6.1 9 1.4 12.6 4.6 283 7 285 305 -0.4 0 -0.1 -0.6 11/05/2005 11:10:00 10.6 1.2 13 6.5 9.9 1.3 13.3 6.5 285 7 292 305 -0.4 0 0.3 -0.6 11/05/2005 11:20:00 9.5 1.2 12.2 6.1 9.1 1.1 11.8 6.5 289 9 290 305 -0.5 0 -0.4 -0.6 11/05/2005 11:30:00 9.8 1.3 12.2 6.1 9.3 1.3 11.8 5.7 288 6 287 305 -0.6 0 -0.4 -0.6 11/05/2005 11:40:00 9.7 1 12.2 7.2 9.1 1 11.8 6.1 288 6 288 305 -0.6 0 0.1 -0.6 11/05/2005 11:50:00 9.5 1 11.8 6.5 8.9 1.1 11.5 5.3 284 6 279 305 -0.5 0 0.1 -0.6 11/05/2005 12:00:00 9.7 1 11.8 6.5 9.3 1.1 11.5 4.9 289 8 282 305 -0.5 0 -0.4 -0.6 11/05/2005 12:10:00 10.8 1 13 8.4 10.4 1 12.6 8 294 10 297 305 -0.9 0.1 -0.6 -1.1 11/05/2005 12:20:00 10.3 1.1 12.6 7.6 9.9 1.1 12.2 7.6 294 9 292 305 -1.1 0 -0.6 -1.3 11/05/2005 12:30:00 10.6 0.9 12.2 7.6 10.2 0.9 12.6 7.2 296 10 296 305 -1.2 0 -0.8 -1.3 11/05/2005 12:40:00 11 1 13.7 8.4 10.7 1.1 13 8 298 13 303 305 -1.2 0 -0.8 -1.3 11/05/2005 12:50:00 10.3 1.2 12.6 6.1 9.9 1.3 12.6 6.1 292 7 293 305 -1.4 0 -1.1 -1.8 11/05/2005 13:00:00 10.9 0.8 13 8.8 10.7 0.8 12.6 8.4 300 17 303 305 -1.6 0 -1.1 -1.8 11/05/2005 13:10:00 10.7 0.8 12.6 8.4 10.6 0.9 13 8 299 9 323 305 -1.5 0.1 -1.1 -1.8 11/05/2005 13:20:00 10.8 1 13.7 8.8 10.5 1 13.3 8 295 8 303 305 -1.6 0 -1.3 -2 11/05/2005 13:30:00 10.5 1 12.6 8 10.2 1.1 12.2 8 301 17 296 305 -1.8 0 -1.3 -2 11/05/2005 13:40:00 9.7 0.9 11.8 6.8 9.5 0.9 11.8 6.8 298 15 303 305 -1.8 0 -1.3 -2 11/05/2005 13:50:00 8.6 1 11.5 6.5 8.4 1 11.5 5.7 295 10 298 305 -1.9 0 -1.3 -2 11/05/2005 14:00:00 9.5 1.1 11.8 6.8 8.9 1.1 12.2 6.5 287 7 305 305 -1.8 0 -1.8 -2 11/05/2005 14:10:00 10 1.1 12.2 6.5 9.6 1.1 12.2 6.5 293 11 292 305 -1.9 0 -1.8 -2 11/05/2005 14:20:00 10.6 1.1 13.7 8 10.1 1.3 13.7 6.8 286 5 288 305 -2.1 0.1 -1.8 -2.2 11/05/2005 14:30:00 9.2 1.3 11.8 5.7 8.4 1.5 11.1 5.3 284 8 285 305 -2 0 -1.8 -2.2 11/05/2005 14:40:00 9.3 1.1 12.2 6.8 8.7 1 11.8 6.5 284 8 284 305 -1.9 0 -1.8 -2 11/05/2005 14:50:00 9.8 0.9 12.2 7.6 9.3 0.9 11.8 7.2 288 6 282 305 -2.1 0 -1.8 -2.2 11/05/2005 15:00:00 10.8 1 13.3 8.4 10.4 1 12.6 8 291 7 297 305 -2.1 0 -2 -2.2 11/05/2005 15:10:00 10.8 1.2 14.1 8 10.2 1.3 13.7 6.8 289 8 299 305 -2.2 0 -2 -2.4 11/05/2005 15:20:00 10.4 1.4 13.3 6.8 9.4 1.5 12.6 6.1 280 8 279 305 -2.3 0 -2 -2.4 11/05/2005 15:30:00 10.7 1.5 13.3 6.5 9.7 1.5 12.6 5.3 282 6 279 305 -2.4 0 -2 -2.4 11/05/2005 15:40:00 10.6 1.3 13.3 8 9.3 1.3 12.6 6.5 281 8 285 305 -2.4 0 -2.2 -2.4 11/05/2005 15:50:00 10.5 1 12.6 8 9.3 1.1 12.6 5.7 280 7 282 305 -2.4 0 -2.2 -2.7 11/05/2005 16:00:00 10 1.1 13 6.8 9.2 1.3 13 5.3 282 8 285 305 -2.6 0 -2.4 -2.7 11/05/2005 16:10:00 10.4 1.3 13.7 7.6 9.2 1.3 12.2 5.7 281 8 273 305 -2.7 0 -2.4 -2.7 11/05/2005 16:20:00 10.6 1.2 13 6.8 8.6 1.2 11.8 5.3 271 7 273 305 -2.7 0 -2.7 -2.9 11/05/2005 16:30:00 9.7 1.4 13 5.3 7.9 1.3 11.1 4.2 269 7 268 305 -2.7 0 -2.7 -2.9 11/05/2005 16:40:00 10.1 1.8 13.7 5.7 8.6 1.8 12.6 3.8 272 10 259 305 -2.7 0 -2.4 -2.9 11/05/2005 16:50:00 10.6 1.7 14.5 6.1 8.9 1.6 13 5.3 275 8 266 305 -2.8 0 -2.4 -2.9 11/05/2005 17:00:00 11.6 1.4 14.5 6.8 9.5 1.5 13.7 5.3 272 7 269 305 -2.7 0 -2.4 -2.7 11/05/2005 17:10:00 12.7 1.8 16.4 8.4 10.6 1.8 14.1 6.1 273 9 270 305 -2.7 0 -2.4 -2.7 11/05/2005 17:20:00 13 1.5 16.4 8.4 10.4 1.6 14.5 6.1 267 7 276 305 -2.9 0 -2.7 -3.3 11/05/2005 17:30:00 12.8 1.7 16.1 8 10.6 1.7 14.1 5.7 263 8 256 305 -3.2 0 -3.1 -3.3 11/05/2005 17:40:00 13.1 1.8 17.2 8.8 10.5 1.8 14.5 6.1 267 8 264 305 -3.3 0 -3.1 -3.3 11/05/2005 17:50:00 12.2 1.7 15.6 7.6 9.8 1.7 13.7 5.3 265 7 262 305 -3.3 0 -3.3 -3.6 11/05/2005 18:00:00 11.6 1.8 16.4 7.2 9.6 1.6 13.7 6.1 274 9 282 305 -3.3 0 -3.1 -3.6 11/05/2005 18:10:00 12.7 1.7 16.8 6.5 10.4 1.9 15.3 4.9 271 8 275 305 -3.5 0 -2.9 -3.8 11/05/2005 18:20:00 12.5 1.6 15.3 8 10.6 1.7 15.3 6.5 273 8 285 305 -3.3 0 -2.7 -3.3 11/05/2005 18:30:00 11 2 15.3 6.1 9.3 1.8 13.7 3.8 273 10 268 305 -3.3 0 -2.9 -3.3 11/05/2005 18:40:00 11.9 1.5 15.6 7.6 10.6 1.5 14.1 7.2 281 8 280 305 -3.3 0 -2.9 -3.6 11/05/2005 18:50:00 12.6 2.1 16.4 6.8 11.6 2 16.1 6.5 283 7 282 305 -3.9 0 -3.1 -4 11/05/2005 19:00:00 11.4 1.6 14.9 6.1 9.9 1.7 14.5 5.3 278 8 281 305 -3.8 0.2 -3.3 -4 11/05/2005 19:10:00 12.8 1.8 16.4 6.8 11.1 2 15.6 4.9 278 9 282 305 -3.3 0 -2.9 -3.6 11/05/2005 19:20:00 13.2 1.5 16.8 9.1 11.2 1.3 14.5 8.4 274 6 273 305 -3.5 0 -3.3 -3.6 11/05/2005 19:30:00 12 1.3 14.9 7.6 10.4 1.5 14.1 5.7 278 9 278 305 -3.7 0 -3.3 -3.8 11/05/2005 19:40:00 12.3 1 14.5 9.1 11.6 1.3 14.1 8 285 12 285 305 -3.5 0 -3.3 -3.8 11/05/2005 19:50:00 12.5 1.5 15.6 7.2 10.7 1.5 14.9 6.1 276 7 290 305 -3.4 0 -3.3 -3.8 11/05/2005 20:00:00 12 1.5 15.3 8.4 9.8 1.4 13 6.1 272 7 268 305 -3.5 0 -3.3 -3.6 11/05/2005 20:10:00 10.9 1.6 14.9 7.2 10.1 1.7 13.3 5.7 286 10 275 305 -3.7 0.1 -3.3 -3.8 11/05/2005 20:20:00 13.4 1.8 17.2 8.4 11 1.7 14.9 6.8 271 7 276 305 -3.6 0.3 -3.3 -4.5 11/05/2005 20:30:00 10.2 1.3 13.3 6.1 8.5 1.3 11.8 4.9 271 7 269 305 -4.2 0.2 -3.8 -4.5 11/05/2005 20:40:00 12 2.7 17.2 6.1 11 3.2 17.2 4.9 285 16 303 305 -3.6 0.2 -3.3 -4 11/05/2005 20:50:00 12 2 16.8 8.4 11.6 2.2 16.8 7.2 292 9 302 305 -4.4 0.1 -4 -4.7 11/05/2005 21:00:00 10.8 1.6 14.5 6.8 10.4 1.6 14.1 6.1 289 8 294 305 -4.2 0 -4 -4.5 11/05/2005 21:10:00 9.7 1.3 12.2 6.1 8.2 1.3 11.1 4.6 277 8 276 305 -4.2 0.1 -3.8 -4.5 11/05/2005 21:20:00 12 1.8 15.6 6.8 9.8 1.5 13.7 5.3 267 7 263 305 -3.9 0.1 -3.6 -4.2 11/05/2005 21:30:00 11.2 1.5 14.1 7.2 9.6 1.3 13.7 6.5 277 8 268 305 -4.3 0 -4 -4.5 11/05/2005 21:40:00 11.9 1.1 14.1 8.4 11.5 1.3 14.1 7.2 296 13 295 305 -3.9 0.1 -3.3 -4.2 11/05/2005 21:50:00 12 1.6 15.6 8.8 11.7 1.6 15.6 8.8 295 7 290 305 -3.7 0 -3.1 -3.8 11/05/2005 22:00:00 13.2 1.1 15.6 9.5 12.9 1.3 15.6 8.8 294 7 295 305 -3.6 0 -3.1 -3.8 11/05/2005 22:10:00 12.7 1.2 15.3 9.5 12.5 1.3 15.3 8.8 300 10 302 305 -3.6 0 -2.9 -3.8 11/05/2005 22:20:00 12.1 1 14.9 9.9 11.9 1.1 14.9 9.1 301 7 305 305 -3.8 0 -3.1 -4 11/05/2005 22:30:00 10.4 1.1 13 6.8 10.1 1.2 12.6 6.5 291 6 290 305 -3.7 0.1 -3.1 -3.8 11/05/2005 22:40:00 11.5 1.3 14.5 7.6 10.9 1.5 14.1 7.2 290 9 272 305 -3.5 0 -3.3 -3.8 11/05/2005 22:50:00 11.1 1.1 13.3 8 10.8 1.2 13.3 7.6 292 7 294 305 -3.5 0 -3.1 -3.6 11/05/2005 23:00:00 10.6 1.5 14.9 7.6 10.3 1.5 14.1 6.8 296 13 35 305 -3.6 0.1 -3.1 -4 11/05/2005 23:10:00 11.3 2.2 14.5 6.1 11.2 2.2 14.9 6.8 303 18 311 305 -4 0 -3.6 -4.2 11/05/2005 23:20:00 11 1.6 14.9 8.4 11 1.7 14.9 8 306 14 311 305 -4 0 -3.6 -4.2 11/05/2005 23:30:00 9.8 0.8 11.8 7.2 9.7 0.8 11.8 7.2 302 8 297 305 -3.8 0 -3.6 -4 11/05/2005 23:40:00 11.4 1.1 14.1 8.8 11.3 1.2 14.5 8.8 306 15 301 305 -3.6 0 -3.1 -3.8 11/05/2005 23:50:00 10.6 0.8 12.6 8.4 10.6 0.8 13 8.4 305 20 303 305 -3.7 0 -3.6 -3.8 11/06/2005 00:00:00 11.9 1.2 14.9 8.8 11.8 1.2 14.9 8.8 308 11 309 305 -3.8 0 -3.6 -3.8 11/06/2005 00:10:00 11.6 0.9 13.7 8.4 11.6 0.9 13.7 8.8 311 13 306 305 -3.9 0 -3.6 -4 11/06/2005 00:20:00 10.1 1 12.6 7.6 10.1 1 13 8 309 15 307 305 -4.1 0 -4 -4.2 11/06/2005 00:30:00 9.7 0.8 11.5 7.6 9.8 0.8 11.5 7.6 313 8 307 305 -4.2 0 -4 -4.5 11/06/2005 00:40:00 8.3 1 11.8 6.1 8.5 1 11.8 6.5 316 10 322 305 -4.3 0 -3.8 -4.5 11/06/2005 00:50:00 8.2 1 10.3 5.7 8.5 1 10.7 6.1 329 6 330 305 -4.3 0 -4 -4.5 11/06/2005 01:00:00 7.9 1.1 10.3 4.9 8.3 1.1 10.7 5.7 331 8 333 305 -4.4 0 -3.8 -4.5 11/06/2005 01:10:00 8.5 0.8 10.3 6.5 8.9 0.8 10.7 7.2 342 8 343 305 -4.4 0 -4.2 -4.7 11/06/2005 01:20:00 8.2 0.9 9.9 6.1 8.7 0.9 10.7 6.8 337 7 330 305 -4.6 0 -4.5 -4.7 11/06/2005 01:30:00 8.8 0.8 10.7 6.5 9.2 0.8 11.1 7.2 336 6 339 305 -4.6 0 -4.2 -4.7 11/06/2005 01:40:00 9.2 0.9 11.5 7.2 9.6 0.8 12.2 7.6 336 6 333 305 -4.6 0 -4.2 -4.7 11/06/2005 01:50:00 9.1 0.9 11.1 7.2 9.5 0.9 11.5 7.2 339 5 339 305 -4.7 0 -4.5 -4.7 11/06/2005 02:00:00 8.8 0.8 11.1 6.8 9.1 0.9 11.5 6.8 334 6 328 305 -4.6 0 -4.5 -4.7 11/06/2005 02:10:00 8.7 1.1 11.5 6.1 9.1 1.2 11.8 6.5 330 5 321 305 -4.6 0 -4.5 -4.7 11/06/2005 02:20:00 8.7 0.9 11.1 6.5 9.1 0.9 11.5 6.5 324 7 320 305 -4.6 0 -4.5 -4.7 11/06/2005 02:30:00 9.4 1.2 12.6 6.8 9.7 1.2 13 7.2 326 7 316 305 -4.2 0.1 -3.8 -4.7 11/06/2005 02:40:00 9.2 1.2 11.8 5.7 9.5 1.2 11.8 6.1 326 6 333 305 -3.9 0.2 -3.6 -4.2 11/06/2005 02:50:00 10.1 1 12.6 7.6 10.4 1 12.6 7.6 325 5 318 305 -3.6 0 -3.3 -3.8 11/06/2005 03:00:00 9.4 1.1 12.2 6.5 9.8 1.1 12.6 6.8 327 7 329 305 -3.2 0.2 -2.9 -3.8 11/06/2005 03:10:00 8.9 1.1 12.2 6.5 9.2 1.1 12.6 6.5 347 9 358 305 -2.5 0.2 -2 -3.1 11/06/2005 03:20:00 9.6 1.6 13.7 6.8 9.9 1.6 14.5 7.2 358 7 357 305 -2.1 0 -2 -2.2 11/06/2005 03:30:00 8.7 0.9 10.3 6.1 9 0.8 10.3 6.8 15 7 25 305 -1.8 0 -1.8 -2 11/06/2005 03:40:00 8.8 0.8 10.7 6.5 9.1 0.7 11.1 6.8 16 8 2 305 -1.9 0.1 -1.8 -2.2 11/06/2005 03:50:00 10.4 3.1 16.4 5.3 10.5 2.9 16.8 5.7 17 9 11 305 -2.5 0.2 -2.2 -2.9 11/06/2005 04:00:00 16.5 1.5 19.5 11.5 16.5 1.5 19.5 11.5 16 4 16 305 -2.6 0 -2 -2.7 11/06/2005 04:10:00 15.7 1.3 19.5 12.6 15.8 1.3 19.1 12.6 18 4 21 305 -2.1 0.1 -1.8 -2.4 11/06/2005 04:20:00 17.2 1.2 19.5 13.3 17.2 1.3 19.5 13.3 19 4 21 305 -2.3 0.2 -2 -2.7 11/06/2005 04:30:00 17.1 1.3 19.5 13.3 17.1 1.4 20.2 13.3 18 5 13 305 -2.6 0.1 -2.2 -2.7 11/06/2005 04:40:00 16.8 1.2 19.5 12.2 16.8 1.2 19.5 12.6 18 4 23 305 -2.3 0 -2.2 -2.4 11/06/2005 04:50:00 15.3 1.3 17.9 11.5 15.3 1.4 18.7 11.8 25 5 24 305 -2.4 0 -2.4 -2.7 11/06/2005 05:00:00 14.4 0.9 17.2 11.8 14.4 0.9 16.8 11.8 25 4 27 305 -2.5 0 -2.2 -2.7 11/06/2005 05:10:00 15.5 1.2 17.9 11.8 15.5 1.2 18.3 12.6 20 5 29 305 -2.7 0 -2.4 -3.1 11/06/2005 05:20:00 15.9 1.1 17.9 13 15.9 1.2 18.3 12.6 20 5 25 305 -2.6 0.1 -2.4 -3.1 11/06/2005 05:30:00 16 1.1 19.1 13.3 16 1.1 19.5 12.6 18 5 16 305 -2.4 0 -2.2 -2.7 11/06/2005 05:40:00 15.7 1 17.9 12.2 15.8 1.2 18.7 11.8 25 5 23 305 -2.6 0.1 -2.2 -2.7 11/06/2005 05:50:00 15.2 1 18.7 12.6 15.4 1.1 17.9 12.6 18 5 14 305 -2.7 0 -2.4 -2.7 11/06/2005 06:00:00 15 1.4 18.7 10.3 15 1.5 18.7 10.7 16 5 12 305 -2.7 0 -2.4 -2.7 11/06/2005 06:10:00 15.6 1.2 18.3 12.6 15.7 1.2 18.7 12.6 16 5 11 305 -2.8 0 -2.7 -2.9 11/06/2005 06:20:00 14.9 1.1 18.3 11.8 14.9 1.1 17.6 11.8 20 5 24 305 -2.8 0 -2.7 -3.1 11/06/2005 06:30:00 13.8 1.4 17.2 9.5 13.7 1.5 17.2 9.5 25 6 20 305 -3 0 -2.7 -3.1 11/06/2005 06:40:00 14 1.3 17.6 11.1 13.9 1.4 17.6 10.7 27 7 26 305 -2.8 0 -2.7 -3.1 11/06/2005 06:50:00 13.4 1.2 16.4 10.3 13.4 1.3 16.8 10.3 28 6 33 305 -2.8 0 -2.7 -2.9 11/06/2005 07:00:00 14.3 1.2 17.2 11.1 14.4 1.2 17.6 10.3 17 6 13 305 -3.1 0.2 -2.7 -3.3 11/06/2005 07:10:00 15 1.9 19.1 11.1 15 1.8 19.1 10.3 20 9 14 305 -3.2 0 -2.9 -3.3 11/06/2005 07:20:00 14.7 1.2 17.6 11.8 14.7 1.3 17.6 11.5 24 5 23 305 -2.8 0.2 -2.4 -3.3 11/06/2005 07:30:00 14.3 1.2 17.2 11.1 14.4 1.3 17.6 11.5 12 5 11 305 -2.7 0 -2.4 -2.9 11/06/2005 07:40:00 14.8 1.2 18.3 11.8 14.7 1.3 18.7 11.8 23 6 16 305 -3.1 0.1 -2.7 -3.3 11/06/2005 07:50:00 15.6 1.1 17.9 11.8 15.6 1.1 17.9 12.2 17 3 16 305 -2.8 0 -2.7 -3.1 11/06/2005 08:00:00 14.2 1.2 17.6 10.3 14.4 1.2 18.3 10.7 15 5 23 305 -3.1 0.1 -2.7 -3.3 11/06/2005 08:10:00 13.4 1.2 17.2 10.3 13.5 1.3 17.6 10.3 22 6 26 305 -2.9 0 -2.7 -3.3 11/06/2005 08:20:00 14.5 1.4 17.2 10.3 14.4 1.5 17.6 10.7 19 6 21 305 -3.1 0 -2.7 -3.3 11/06/2005 08:30:00 13.9 1 16.8 11.1 14 1.1 16.8 10.7 14 4 15 305 -3.1 0.1 -2.7 -3.3 11/06/2005 08:40:00 15.1 1.1 17.9 12.2 15.1 1.1 17.9 11.8 16 5 17 305 -3.1 0 -2.9 -3.3 11/06/2005 08:50:00 15.3 1.1 17.9 11.8 15.3 1.1 18.3 11.5 10 3 12 305 -3 0.1 -2.7 -3.3 11/06/2005 09:00:00 14.3 1 16.4 11.5 14.4 1 16.8 11.8 14 4 18 305 -3 0 -2.7 -3.1 11/06/2005 09:10:00 14 1.2 16.4 11.1 14.1 1.2 17.2 11.1 21 5 16 305 -3 0 -2.7 -3.1 11/06/2005 09:20:00 13.5 1.1 15.6 10.3 13.5 1.2 16.1 10.7 22 5 24 305 -2.9 0 -2.7 -3.1 11/06/2005 09:30:00 12.8 1 15.3 10.3 12.9 1 15.3 9.9 22 6 27 305 -3 0 -2.2 -3.3 11/06/2005 09:40:00 13.7 1.3 16.1 9.9 13.8 1.3 16.8 9.9 17 4 18 305 -3.1 0.2 -2.7 -3.6 11/06/2005 09:50:00 13.6 1.1 16.1 11.1 13.6 1.1 16.1 11.1 22 6 14 305 -3 0 -2.7 -3.3 11/06/2005 10:00:00 14 0.9 16.4 11.5 14.1 1 16.8 11.5 13 4 12 305 -3.1 0.2 -2.7 -3.6 11/06/2005 10:10:00 12.6 0.9 14.5 10.3 12.6 1 14.5 9.9 27 6 36 305 -3.4 0.1 -2.7 -3.8 11/06/2005 10:20:00 14.3 1.2 17.2 11.1 14.3 1.3 16.8 11.5 33 5 31 305 -3.3 0.2 -3.1 -3.8 11/06/2005 10:30:00 12.1 1 15.6 9.9 12.1 1 15.3 9.1 31 7 35 305 -3.4 0.3 -2.7 -3.8 11/06/2005 10:40:00 13.2 1.1 15.6 10.3 13.2 1.2 16.1 9.9 18 8 13 305 -3 0.2 -2.7 -3.3 11/06/2005 10:50:00 13.1 0.8 14.9 9.9 13.2 1 15.3 10.3 19 9 27 305 -2.9 0.1 -2.4 -3.3 11/06/2005 11:00:00 10.8 1 13.3 8 11.1 1 13.7 8.4 7 7 7 305 -3.2 0 -3.1 -3.3 11/06/2005 11:10:00 12.8 1.3 16.1 9.1 12.9 1.3 16.1 9.9 15 5 16 305 -3 0.1 -2.7 -3.3 11/06/2005 11:20:00 12.6 1 14.9 9.9 12.7 1 14.9 9.5 18 4 15 305 -3.2 0 -2.9 -3.3 11/06/2005 11:30:00 12.6 1.2 15.3 9.1 12.9 1.2 15.6 9.5 12 4 11 305 -3.1 0.1 -2.9 -3.3 11/06/2005 11:40:00 13.9 1.8 17.2 9.5 14 1.9 17.6 9.9 19 6 12 305 -3.5 0.3 -2.7 -4 11/06/2005 11:50:00 13 1.5 16.1 9.5 13.2 1.5 16.4 9.5 20 6 18 305 -3.3 0.1 -3.1 -3.8 11/06/2005 12:00:00 11.8 2.3 16.4 6.5 11.8 2.3 16.4 6.8 29 6 29 305 -3.6 0.2 -3.3 -3.8 11/06/2005 12:10:00 12.9 0.9 15.3 11.1 13 1 15.6 11.1 29 7 37 305 -3.2 0.1 -2.9 -3.6 11/06/2005 12:20:00 13.4 1.1 17.6 10.3 13.5 1.1 16.4 10.3 23 4 31 305 -2.8 0 -2.4 -3.1 11/06/2005 12:30:00 13 1.3 16.4 9.9 13 1.3 16.1 9.9 33 6 33 305 -3.1 0.1 -2.7 -3.3 11/06/2005 12:40:00 11.2 1.3 13.7 8 11.3 1.5 14.1 8 41 6 49 305 -3.1 0 -2.7 -3.3 11/06/2005 12:50:00 12.5 1.2 15.6 9.5 12.6 1.2 16.1 9.5 31 4 32 305 -2.8 0 -2.4 -3.1 11/06/2005 13:00:00 13.5 1.1 16.1 10.7 13.4 1.2 16.1 10.3 28 4 26 305 -2.9 0.1 -2.7 -3.3 11/06/2005 13:10:00 12.2 0.8 13.7 9.9 12.2 1 14.5 9.1 25 6 18 305 -2.8 0.1 -2.4 -3.1 11/06/2005 13:20:00 12 0.9 14.1 9.5 12.1 1 15.3 9.5 35 6 33 305 -2.6 0.1 -2.4 -2.7 11/06/2005 13:30:00 12.1 1 14.5 9.5 12.1 1.1 14.5 9.1 37 6 42 305 -2.5 0 -2 -2.7 11/06/2005 13:40:00 12.2 1.1 14.9 9.9 12.4 1.2 15.3 9.1 33 5 40 305 -2.6 0.1 -2.2 -2.9 11/06/2005 13:50:00 11.5 1 13.7 8.8 11.7 1.2 14.1 9.1 18 8 15 305 -2.7 0 -2.4 -2.9 11/06/2005 14:00:00 11.8 1 13.7 8.4 12.1 1 14.1 8.8 8 3 6 305 -3.5 0.2 -2.7 -3.8 11/06/2005 14:10:00 10.9 1 12.6 8.4 11.2 1 13 8.8 6 3 6 305 -3.7 0.1 -3.1 -3.8 11/06/2005 14:20:00 10.7 1 12.6 8 11 0.9 12.6 8.4 12 5 18 305 -3.1 0.2 -2.7 -3.6 11/06/2005 14:30:00 10.5 0.8 12.2 8.4 10.8 0.9 13 8 14 6 13 305 -3 0 -2.7 -3.1 11/06/2005 14:40:00 11 1 13.3 8.8 11.2 1 13.7 8.8 11 5 13 305 -3.2 0.1 -2.9 -3.6 11/06/2005 14:50:00 11.3 0.9 13.7 9.5 11.5 1 14.1 9.1 11 6 7 305 -3.3 0 -3.1 -3.6 11/06/2005 15:00:00 12.2 1 14.9 9.9 12.6 1 15.3 9.9 0 5 355 305 -3 0.1 -2.7 -3.3 11/06/2005 15:10:00 12.4 0.8 14.5 9.9 12.8 1 15.3 9.9 0 5 3 305 -2.8 0 -2.7 -3.1 11/06/2005 15:20:00 11.8 1 14.9 9.5 12.2 1 15.6 9.5 359 5 353 305 -2.8 0 -2.7 -3.1 11/06/2005 15:30:00 10.9 0.7 12.6 9.1 11.2 0.8 13 9.1 3 4 4 305 -2.8 0 -2.7 -2.9 11/06/2005 15:40:00 11.1 0.8 13 9.5 11.5 0.8 13.3 9.5 6 6 10 305 -2.8 0 -2.7 -2.9 11/06/2005 15:50:00 10.8 1 13.3 8.8 11.1 1 13.7 8.8 9 6 357 305 -2.6 0 -2.4 -2.7 11/06/2005 16:00:00 9.7 1.3 12.2 6.8 10 1.4 12.6 6.8 8 6 4 305 -2.7 0 -2.4 -3.1 11/06/2005 16:10:00 11.6 1.2 14.1 8.8 11.9 1.2 14.5 8.8 5 7 0 305 -2.6 0 -2.4 -2.7 11/06/2005 16:20:00 11.3 0.9 13.7 8.8 11.6 0.9 13.7 9.1 12 7 16 305 -2.4 0 -2.2 -2.7 11/06/2005 16:30:00 11 1.1 13.7 8.4 11.2 1.2 14.1 7.6 14 7 13 305 -2.6 0 -2.4 -3.1 11/06/2005 16:40:00 9.6 1.1 11.8 7.2 9.9 1.1 12.6 7.6 16 6 7 305 -3.3 0 -2.9 -3.6 11/06/2005 16:50:00 11.4 1.3 14.5 8.4 11.7 1.3 14.5 8.4 7 6 11 305 -2.9 0.1 -2.7 -3.3 11/06/2005 17:00:00 11 1.2 13.7 7.6 11.4 1.2 14.1 8.4 4 4 7 305 -3.1 0 -2.9 -3.3 11/06/2005 17:10:00 11.2 1.2 14.1 8.4 11.5 1.2 14.1 8 7 6 8 305 -3.1 0.1 -2.7 -3.3 11/06/2005 17:20:00 12.2 0.8 14.1 9.9 12.5 0.7 14.1 10.3 4 4 0 305 -3.1 0 -2.7 -3.1 11/06/2005 17:30:00 11.8 1.7 16.4 8 12.1 1.6 16.4 8.4 4 5 9 305 -3 0 -2.7 -3.3 11/06/2005 17:40:00 12.7 1 15.6 9.9 12.9 1.1 15.6 9.9 7 5 8 305 -2.7 0 -2.4 -2.7 11/06/2005 17:50:00 12.5 0.8 14.5 10.7 12.7 0.9 14.5 10.3 15 5 11 305 -2.3 0 -1.8 -2.4 11/06/2005 18:00:00 11.9 0.9 14.5 9.5 12.1 1 15.3 9.5 11 8 0 305 -2.2 0 -2 -2.4 11/06/2005 18:10:00 12.7 1 15.3 9.5 12.9 1.1 15.6 9.9 11 5 11 305 -2.3 0 -2 -2.7 11/06/2005 18:20:00 12.5 1.5 15.6 9.1 12.7 1.5 15.6 9.1 6 5 4 305 -2.5 0.1 -2 -2.7 11/06/2005 18:30:00 12.5 1 14.5 9.9 12.6 1 14.9 9.9 11 4 11 305 -2.3 0 -2 -2.4 11/06/2005 18:40:00 11.7 1.2 16.1 8.8 12 1.3 16.8 8.8 11 8 8 305 -2.3 0 -2 -2.4 11/06/2005 18:50:00 11.8 1.1 14.9 9.5 12 1.1 14.9 8.8 16 5 11 305 -2.2 0 -1.5 -2.2 11/06/2005 19:00:00 12.4 1 14.5 9.9 12.6 1 14.5 9.9 19 4 22 305 -2.2 0 -1.8 -2.4 11/06/2005 19:10:00 13.2 0.8 15.3 9.9 13.4 0.8 15.3 10.3 17 4 17 305 -2.2 0 -1.8 -2.4 11/06/2005 19:20:00 12.9 1 15.3 9.9 13.1 1.1 15.6 9.5 17 5 24 305 -2.2 0 -2 -2.4 11/06/2005 19:30:00 12.6 0.9 14.5 10.3 12.9 0.9 14.9 10.3 12 5 7 305 -2.3 0 -2 -2.4 11/06/2005 19:40:00 13.8 1.7 16.8 8.4 13.9 1.7 17.2 9.9 21 9 21 305 -2.5 0.3 -2.2 -3.3 11/06/2005 19:50:00 13.6 1 16.1 11.1 13.7 1.1 16.8 10.7 26 3 28 305 -3.2 0 -3.1 -3.3 11/06/2005 20:00:00 11.9 0.7 13.7 9.5 12.1 0.8 14.1 9.1 15 5 15 305 -3 0 -2.4 -3.3 11/06/2005 20:10:00 12 1 14.9 9.1 12.2 1 14.9 9.1 11 5 9 305 -2.9 0 -2.7 -3.1 11/06/2005 20:20:00 13 1 14.9 9.9 13.2 1 15.3 9.5 17 6 14 305 -2.6 0.1 -1.8 -3.1 11/06/2005 20:30:00 14.7 1.7 17.9 11.5 14.7 1.7 18.7 11.1 23 5 20 305 -2.5 0.2 -2.2 -3.1 11/06/2005 20:40:00 13.6 2 17.9 9.9 13.7 2 17.2 9.9 20 3 22 305 -3.5 0.2 -2.9 -3.8 11/06/2005 20:50:00 11.1 1 14.5 8.8 11.2 1 14.1 8.8 23 5 25 305 -2.8 0.3 -2 -3.3 11/06/2005 21:00:00 14.3 1.2 16.4 10.7 14.3 1.2 16.8 11.1 26 5 28 305 -3 0.3 -2.4 -3.6 11/06/2005 21:10:00 12.8 0.8 14.9 10.3 13 1 15.3 10.7 20 4 25 305 -3.3 0 -3.1 -3.6 11/06/2005 21:20:00 12.4 0.9 14.9 10.3 12.5 1 15.3 9.9 25 5 22 305 -3.2 0 -3.1 -3.3 11/06/2005 21:30:00 11.6 1.6 14.5 8 11.7 1.7 14.9 7.6 48 5 40 305 -4 0.4 -3.1 -4.7 11/06/2005 21:40:00 10.4 1 12.6 8 10.5 1.1 13.3 8 50 6 53 305 -3.9 0.1 -3.3 -4.2 11/06/2005 21:50:00 10.3 0.9 13 8 10.4 1 13.3 8 50 8 56 305 -3.3 0 -2.7 -3.6 11/06/2005 22:00:00 9.9 0.8 11.8 8 10 0.8 11.8 8 45 9 53 305 -2.9 0.1 -2.7 -3.3 11/06/2005 22:10:00 9.7 1 11.8 7.2 9.8 1 12.2 7.2 38 11 40 305 -2.7 0.1 -2.4 -2.9 11/06/2005 22:20:00 10.1 1 13 7.6 10.3 1 13.3 7.6 53 8 45 305 -2.6 0.1 -2.4 -2.9 11/06/2005 22:30:00 9.7 0.9 11.8 6.5 9.7 0.9 12.2 7.2 67 6 59 305 -3 0.1 -2.7 -3.3 11/06/2005 22:40:00 10.5 1.3 13.3 8 10.7 1.3 13.7 8 58 6 57 305 -3.6 0.2 -3.1 -4 11/06/2005 22:50:00 11.1 1.1 12.6 8 11.2 1.1 13 8.4 43 6 37 305 -4 0 -3.8 -4.2 11/06/2005 23:00:00 9.1 1 11.8 6.5 9.3 1 12.2 7.2 43 6 58 305 -3.7 0.3 -3.1 -4.2 11/06/2005 23:10:00 11.9 1.3 15.3 8 12 1.3 15.3 8.4 56 5 56 305 -3.7 0.4 -3.1 -4.2 11/06/2005 23:20:00 10.2 1.1 13.3 8 10.3 1.1 13.3 8 57 6 62 305 -4.2 0 -3.6 -4.5 11/06/2005 23:30:00 10.8 1 13 7.2 10.9 1 13 7.6 57 6 52 305 -3.9 0.1 -3.6 -4 11/06/2005 23:40:00 11.3 1 14.9 8.8 11.3 1 13.7 8.4 57 7 66 305 -3.5 0.1 -3.1 -3.8 11/06/2005 23:50:00 12 0.9 14.5 9.1 12 1 14.9 9.1 50 7 50 305 -3.1 0 -2.7 -3.3 11/07/2005 00:00:00 12.7 0.9 14.9 9.9 12.7 1 14.5 9.5 54 6 48 305 -3.1 0.1 -2.7 -3.3 11/07/2005 00:10:00 13.4 0.9 16.1 10.7 13.4 1 15.6 10.3 53 6 51 305 -3.2 0 -2.7 -3.3 11/07/2005 00:20:00 14 1.1 16.8 11.1 14 1.1 16.4 11.1 46 5 51 305 -3.2 0 -3.1 -3.3 11/07/2005 00:30:00 12.8 0.9 14.5 10.3 12.9 1 15.3 9.5 45 5 39 305 -3.3 0 -2.9 -3.6 11/07/2005 00:40:00 12.8 1.2 17.2 10.3 12.8 1.3 17.2 9.5 42 5 48 305 -3.3 0 -2.7 -3.3 11/07/2005 00:50:00 14.5 1.1 17.2 11.5 14.5 1.1 16.8 11.8 38 4 41 305 -3.3 0 -2.7 -3.6 11/07/2005 01:00:00 15.6 1.1 18.3 13 15.5 1.2 18.3 12.6 38 5 36 305 -3.5 0 -2.9 -3.8 11/07/2005 01:10:00 16.1 1.2 18.7 12.6 16 1.2 18.7 11.8 32 5 36 305 -3.5 0 -3.1 -3.8 11/07/2005 01:20:00 15.3 1.2 18.7 12.6 15.2 1.3 18.7 11.8 29 5 28 305 -3.7 0 -3.3 -3.8 11/07/2005 01:30:00 16.5 1.1 19.5 13 16.5 1.1 19.5 12.6 27 5 27 305 -3.9 0 -3.8 -4 11/07/2005 01:40:00 16.8 1.1 19.5 13.3 16.7 1.2 19.9 13 30 5 32 305 -4.1 0 -3.8 -4.5 11/07/2005 01:50:00 17.6 1 20.2 14.1 17.3 1.1 19.9 13.7 30 5 35 305 -4.3 0 -4 -4.5 11/07/2005 02:00:00 17 1.5 19.9 12.2 16.7 1.6 20.2 12.6 27 5 23 305 -4.3 0.1 -4 -4.7 11/07/2005 02:10:00 16.7 1.5 19.9 12.2 16.6 1.5 19.9 13 31 5 29 305 -4.7 0.1 -4.5 -4.9 11/07/2005 02:20:00 16.3 1.3 19.9 12.6 16.2 1.4 19.9 12.6 30 6 26 305 -4.5 0.1 -4 -4.7 11/07/2005 02:30:00 16.6 1.2 19.9 13 16.5 1.3 19.9 13.7 25 5 26 305 -4.5 0 -4 -4.7 11/07/2005 02:40:00 15.6 1.2 19.5 12.6 15.6 1.2 18.7 12.2 25 5 30 305 -4.6 0 -4.5 -4.7 11/07/2005 02:50:00 15.7 1.1 18.7 12.6 15.7 1.1 19.1 13 23 6 14 305 -4.6 0 -4.2 -4.7 11/07/2005 03:00:00 15.9 1.1 19.1 13 15.9 1.1 19.1 13 25 4 29 305 -4.7 0.1 -4.5 -4.9 11/07/2005 03:10:00 15.4 1.2 19.5 12.6 15.3 1.3 19.5 12.2 27 5 23 305 -4.8 0 -4.7 -5.1 11/07/2005 03:20:00 15.2 1.5 18.7 11.5 15.1 1.5 18.7 10.7 31 5 30 305 -4.9 0 -4.7 -5.1 11/07/2005 03:30:00 15.8 1.2 19.5 12.2 15.6 1.3 18.7 11.5 32 8 42 305 -4.9 0.1 -4.2 -5.1 11/07/2005 03:40:00 15.5 1.5 24 12.2 15.4 1.5 21.8 11.1 34 5 17 305 -4.9 0 -4.7 -4.9 11/07/2005 03:50:00 15.6 1.3 18.7 12.6 15.5 1.3 18.7 12.2 32 4 34 305 -4.9 0 -4.7 -4.9 11/07/2005 04:00:00 15.6 1.7 19.5 10.7 15.4 1.7 19.5 11.1 28 6 40 305 -5.1 0.1 -4.7 -5.6 11/07/2005 04:10:00 14.3 1.5 17.9 10.3 14.2 1.5 17.9 10.3 26 5 37 305 -5.2 0.2 -4.7 -5.6 11/07/2005 04:20:00 15.5 1.3 19.1 11.8 15.5 1.4 19.5 11.1 33 7 27 305 -5.2 0 -4.7 -5.6 11/07/2005 04:30:00 16.2 1.2 19.1 13 16.1 1.2 19.1 12.6 32 7 29 305 -5.3 0.2 -4.9 -5.8 11/07/2005 04:40:00 14.7 1.1 17.2 11.8 14.7 1.2 17.6 11.8 32 7 27 305 -5.2 0.2 -4.7 -5.8 11/07/2005 04:50:00 15.9 1.2 18.7 13 15.9 1.3 19.1 12.6 29 5 22 305 -5 0.2 -4.7 -5.8 11/07/2005 05:00:00 14.5 1.2 17.9 11.5 14.4 1.3 17.2 11.1 28 6 28 305 -5.5 0.2 -4.9 -5.8 11/07/2005 05:10:00 15.2 1.2 17.9 11.8 15.1 1.2 18.3 12.2 31 5 30 305 -5 0 -4.7 -5.1 11/07/2005 05:20:00 14.9 1.1 17.9 12.2 14.9 1.2 17.6 11.8 36 4 35 305 -5 0 -4.9 -5.3 11/07/2005 05:30:00 15.9 1.4 18.7 12.6 15.9 1.4 19.5 13 26 5 25 305 -5.1 0.1 -4.7 -5.6 11/07/2005 05:40:00 16 1.5 19.5 11.8 16 1.7 20.2 11.8 41 6 45 305 -5.7 0.4 -4.7 -6.2 11/07/2005 05:50:00 15.7 1.5 19.5 12.2 15.7 1.5 19.5 11.8 29 7 26 305 -5.6 0.2 -5.1 -6 11/07/2005 06:00:00 16.2 1.3 18.7 12.6 16.1 1.3 18.7 12.6 32 9 27 305 -5.8 0.1 -5.6 -6.2 11/07/2005 06:10:00 15.3 1.1 17.9 13 15.3 1.2 18.3 12.2 46 5 49 305 -6.3 0.3 -5.8 -6.9 11/07/2005 06:20:00 14.4 1.3 17.6 11.5 14.3 1.3 17.9 11.1 43 7 51 305 -6.2 0.1 -5.8 -6.7 11/07/2005 06:30:00 14.3 1.5 17.6 10.7 14.3 1.5 17.6 10.7 41 5 50 305 -6.2 0.1 -5.8 -6.7 11/07/2005 06:40:00 13.8 1.3 17.2 10.7 13.7 1.4 17.2 10.3 45 6 49 305 -6.1 0 -5.8 -6.4 11/07/2005 06:50:00 14.4 1.4 19.1 11.8 14.3 1.5 19.9 11.5 47 6 46 305 -6.2 0 -5.8 -6.4 11/07/2005 07:00:00 14.5 1.5 17.2 10.3 14.5 1.6 17.6 10.7 41 6 54 305 -6 0 -5.8 -6.2 11/07/2005 07:10:00 15.4 1.8 20.6 10.3 15.3 1.8 20.6 11.1 36 7 30 305 -6.3 0.4 -5.6 -7.1 11/07/2005 07:20:00 13.6 1.4 17.9 10.3 13.5 1.4 18.3 10.3 34 6 30 305 -6.3 0.1 -6 -6.7 11/07/2005 07:30:00 13.6 1.1 15.6 10.7 13.5 1.2 16.1 10.7 36 6 31 305 -6.1 0 -5.8 -6.4 11/07/2005 07:40:00 14.9 1.6 19.5 11.1 14.7 1.6 19.5 10.7 39 8 38 305 -6.1 0.1 -5.8 -6.7 11/07/2005 07:50:00 14.4 1.6 18.7 9.9 14.2 1.6 18.3 10.3 29 6 35 305 -6.4 0.1 -5.8 -6.7 11/07/2005 08:00:00 14.8 1.4 18.7 11.5 14.8 1.5 18.7 11.1 34 5 28 305 -6.3 0.1 -6 -6.7 11/07/2005 08:10:00 13.9 1.3 18.3 11.1 13.9 1.2 18.3 10.7 31 8 26 305 -6.3 0.1 -5.8 -6.7 11/07/2005 08:20:00 14.7 1.8 18.7 11.1 14.6 1.9 18.3 9.9 38 9 39 305 -6.3 0.3 -5.8 -6.9 11/07/2005 08:30:00 13.6 1.4 16.8 10.7 13.5 1.4 16.8 10.7 45 6 42 305 -6.5 0.1 -6.2 -6.9 11/07/2005 08:40:00 12.8 1 16.1 9.9 12.8 1.1 15.6 10.3 48 5 44 305 -6.5 0 -6.2 -6.7 11/07/2005 08:50:00 14 1.2 17.9 10.3 13.9 1.2 17.6 9.9 36 8 35 305 -6.6 0.1 -6.2 -6.9 11/07/2005 09:00:00 13.5 1.7 17.2 9.9 13.5 1.8 17.6 9.5 43 8 43 305 -6.7 0.2 -6 -7.1 11/07/2005 09:10:00 14.5 1 17.2 12.2 14.5 1 16.8 11.8 33 5 40 305 -6.2 0.2 -5.8 -6.7 11/07/2005 09:20:00 13.9 1.5 17.6 10.3 13.9 1.5 17.6 10.3 37 6 46 305 -6 0 -5.8 -6.2 11/07/2005 09:30:00 13.8 1.3 16.8 11.1 13.8 1.3 16.8 10.3 34 6 26 305 -6.3 0.1 -6 -6.9 11/07/2005 09:40:00 13.5 1.2 16.1 10.3 13.6 1.2 16.1 10.3 39 14 25 305 -6.2 0.1 -5.8 -6.7 11/07/2005 09:50:00 14.2 1.1 16.1 11.1 14.2 1.2 16.4 10.7 40 5 48 305 -6.3 0.2 -6 -6.9 11/07/2005 10:00:00 12.4 0.9 14.9 9.9 12.6 1 14.9 10.3 45 6 39 305 -6.7 0 -6.4 -6.9 11/07/2005 10:10:00 11.7 1.3 14.1 8.4 11.7 1.3 14.1 8.8 31 8 30 305 -6.8 0.1 -6.4 -6.9 11/07/2005 10:20:00 13.1 1.2 16.8 9.1 13.1 1.3 16.8 9.1 37 7 48 305 -6.7 0 -6.4 -6.9 11/07/2005 10:30:00 12.5 1.2 15.3 8.8 12.5 1.3 15.6 9.9 37 7 23 305 -6.7 0.2 -6.2 -7.1 11/07/2005 10:40:00 13.8 1.3 16.8 10.7 13.8 1.3 17.6 9.9 42 7 42 305 -6.4 0 -6.2 -6.7 11/07/2005 10:50:00 14.2 1.3 17.6 11.1 14.1 1.5 17.2 10.3 50 7 34 305 -6.3 0 -6 -6.7 11/07/2005 11:00:00 14.9 1 17.6 12.2 14.9 1 17.2 11.8 45 6 52 305 -6.1 0 -5.8 -6.4 11/07/2005 11:10:00 15.5 1.4 18.7 12.2 15.4 1.4 18.3 11.8 52 5 58 305 -6.2 0 -6 -6.4 11/07/2005 11:20:00 14.9 1.3 17.6 11.8 14.9 1.4 17.9 11.5 48 5 42 305 -6.2 0 -6 -6.4 11/07/2005 11:30:00 15.6 1.3 19.5 12.6 15.5 1.4 19.1 11.8 50 6 43 305 -6.3 0.2 -5.8 -6.7 11/07/2005 11:40:00 15.3 1.3 18.3 11.1 15.2 1.4 18.7 11.5 48 5 45 305 -6.4 0.1 -6 -6.9 11/07/2005 11:50:00 14.8 1.4 17.9 11.1 14.7 1.5 18.3 11.1 46 8 46 305 -6.3 0.1 -5.8 -6.7 11/07/2005 12:00:00 14.7 1.5 18.3 10.3 14.6 1.6 18.7 10.3 38 8 52 305 -6 0.1 -5.8 -6.2 11/07/2005 12:10:00 14.4 1.1 17.9 11.5 14.4 1.2 17.6 11.1 33 5 32 305 -5.9 0.1 -5.6 -6 11/07/2005 12:20:00 15.1 1.4 17.9 11.8 15.1 1.5 18.3 11.1 45 7 31 305 -6.1 0 -5.8 -6.4 11/07/2005 12:30:00 14.9 1.6 18.7 10.7 14.9 1.7 19.1 10.3 49 6 54 305 -6.2 0 -6 -6.4 11/07/2005 12:40:00 13.6 1.6 17.9 10.3 13.5 1.5 17.2 10.3 44 7 46 305 -6.1 0.1 -5.8 -6.7 11/07/2005 12:50:00 13.8 1.2 17.2 11.1 13.7 1.3 16.8 10.3 43 7 50 305 -6.4 0.3 -5.8 -6.9 11/07/2005 13:00:00 13 1.4 16.4 9.9 12.9 1.5 16.4 9.1 36 6 36 305 -6.4 0.1 -6 -6.7 11/07/2005 13:10:00 14.1 1.1 16.8 11.1 14.2 1.1 17.2 11.8 45 6 46 305 -6.7 0.2 -6.2 -7.1 11/07/2005 13:20:00 12.6 1 16.1 9.9 12.6 1.1 15.6 9.5 46 5 44 305 -6.5 0.1 -6.2 -6.7 11/07/2005 13:30:00 13.2 1.2 16.4 9.9 13.3 1.3 16.4 9.9 30 11 41 305 -6.6 0.2 -6 -6.9 11/07/2005 13:40:00 12.2 1.4 17.2 9.1 12.3 1.4 17.6 9.5 29 4 33 305 -6.8 0.3 -6.2 -7.3 11/07/2005 13:50:00 13.5 1.2 16.8 11.1 13.6 1.3 17.2 10.7 31 6 31 305 -6.4 0 -6.2 -6.7 11/07/2005 14:00:00 14 1.2 17.6 11.8 14 1.2 17.6 11.5 36 8 27 305 -6.4 0.1 -6 -6.7 11/07/2005 14:10:00 13.8 1 16.4 11.1 13.8 1 16.4 11.1 34 6 40 305 -6.2 0.2 -5.8 -6.7 11/07/2005 14:20:00 14.7 1.6 19.5 11.8 14.6 1.5 19.9 11.8 34 6 32 305 -6.1 0.2 -5.6 -6.7 11/07/2005 14:30:00 13 1.3 16.8 9.9 13 1.3 16.4 9.1 30 12 44 305 -6.5 0.1 -6.2 -6.9 11/07/2005 14:40:00 15.5 1.9 18.7 11.5 15.5 2 18.7 11.5 43 7 51 305 -6.5 0.1 -6 -6.9 11/07/2005 14:50:00 13.6 1.7 19.5 10.3 13.7 1.7 19.1 10.3 34 6 26 305 -6.2 0.2 -5.8 -6.7 11/07/2005 15:00:00 15 1.1 17.9 12.2 14.9 1 17.6 12.6 25 6 17 305 -6.4 0.2 -6 -6.9 11/07/2005 15:10:00 13.9 1.5 18.7 10.3 13.9 1.5 18.3 9.5 23 8 13 305 -6.2 0.2 -5.6 -6.7 11/07/2005 15:20:00 14.8 1.2 19.1 10.7 14.8 1.1 17.9 10.7 27 14 23 305 -6.1 0.1 -5.8 -6.4 11/07/2005 15:30:00 15.2 1.2 17.9 11.8 15.1 1.2 17.9 12.2 31 5 32 305 -6.7 0 -6.4 -6.9 11/07/2005 15:40:00 14.5 1.2 18.3 12.2 14.5 1.2 17.9 11.1 31 7 24 305 -6.8 0.2 -6.4 -7.1 11/07/2005 15:50:00 14.5 1.5 17.6 11.1 14.5 1.4 17.6 11.5 40 6 39 305 -6.9 0 -6.7 -7.1 11/07/2005 16:00:00 13.4 2.1 20.2 9.1 13.4 2.2 20.6 9.9 33 7 29 305 -6.6 0.2 -6.2 -7.3 11/07/2005 16:10:00 14.5 1 17.6 11.8 14.5 1.1 17.6 11.1 33 6 33 305 -6.5 0.1 -6.2 -7.1 11/07/2005 16:20:00 16.4 1.2 20.2 13.3 16.3 1.3 19.5 12.2 11 10 27 305 -6.9 0.2 -6.2 -7.3 11/07/2005 16:30:00 14.5 1.9 18.7 10.3 14.6 1.9 19.1 9.9 21 12 12 305 -6.9 0.2 -6.2 -7.3 11/07/2005 16:40:00 14.1 1.7 18.7 11.1 14.1 1.7 19.1 11.1 21 7 22 305 -6.9 0.1 -6.7 -7.3 11/07/2005 16:50:00 15.6 1.5 20.2 11.8 15.5 1.5 19.9 12.2 29 6 31 305 -6.7 0.2 -6.2 -7.3 11/07/2005 17:00:00 16.9 2.9 23.7 11.5 16.8 3.1 23.7 12.2 29 5 33 305 -7.1 0.3 -6.4 -7.5 11/07/2005 17:10:00 16.9 1.5 21 13.3 16.6 1.5 21.4 13 27 5 23 305 -6.9 0.2 -6.4 -7.1 11/07/2005 17:20:00 16.4 1.8 20.2 11.8 16.3 1.8 20.2 11.1 24 7 25 305 -6.2 0.1 -6 -6.7 11/07/2005 17:30:00 16.3 2 21 12.2 16.2 2 22.1 12.6 25 9 15 305 -6.5 0.3 -6 -7.1 11/07/2005 17:40:00 18.5 1.2 21 15.3 18.4 1.3 21.4 14.1 9 6 10 305 -6.1 0 -5.6 -6.4 11/07/2005 17:50:00 18.4 1.5 22.9 14.5 18.4 1.6 22.1 14.5 15 5 10 305 -5.9 0.1 -5.6 -6.2 11/07/2005 18:00:00 19.5 1.3 23.7 16.4 19.5 1.4 23.7 16.1 17 4 20 305 -6.1 0 -5.8 -6.2 11/07/2005 18:10:00 18.7 1.8 24 13.7 18.6 1.9 24.4 13.7 15 7 19 305 -6.3 0.3 -6 -7.1 11/07/2005 18:20:00 16.5 2.1 21.8 11.8 16.4 2.2 22.1 11.1 31 10 12 305 -7.2 0.2 -6.9 -7.5 11/07/2005 18:30:00 17.5 1.7 22.1 13.3 17.4 1.7 22.1 13 21 5 14 305 -6.4 0.2 -5.8 -6.9 11/07/2005 18:40:00 18.5 1.5 22.9 14.5 18.3 1.6 22.6 13.7 23 7 22 305 -6.3 0.3 -5.6 -6.9 11/07/2005 18:50:00 18.2 1.4 21.8 14.1 18.1 1.4 21.4 13.3 26 8 28 305 -6.8 0.2 -6.7 -7.3 11/07/2005 19:00:00 18.7 1.8 23.3 13.7 18.6 1.9 22.6 13 21 5 24 305 -6.6 0.2 -6 -7.1 11/07/2005 19:10:00 17.7 1.7 21.8 13 17.7 1.7 22.1 12.2 19 6 12 305 -6.2 0.1 -5.8 -6.4 11/07/2005 19:20:00 18.7 1.5 22.1 14.1 18.5 1.5 22.6 14.5 14 5 12 305 -6.6 0.2 -6 -7.1 11/07/2005 19:30:00 16.5 2 20.6 11.8 16.4 2 21 11.5 22 11 22 305 -7 0.1 -6.7 -7.5 11/07/2005 19:40:00 15.7 1.6 20.2 12.2 15.6 1.7 20.2 11.5 25 6 19 305 -7.1 0.1 -6.7 -7.5 11/07/2005 19:50:00 17.4 1.9 22.6 13.3 17.3 1.8 22.6 13.3 19 8 16 305 -6.4 0.3 -6 -7.1 11/07/2005 20:00:00 19.2 1.5 23.3 15.3 19.1 1.7 24 15.3 15 5 9 305 -6.5 0.4 -6 -7.3 11/07/2005 20:10:00 16.3 2.6 23.7 11.5 16.1 2.5 24 11.5 32 9 25 305 -7.1 0.2 -6.7 -7.5 11/07/2005 20:20:00 15.5 2 21 11.5 15.4 2 21 11.5 26 7 21 305 -6.9 0.2 -6.4 -7.3 11/07/2005 20:30:00 15.2 1.8 19.1 10.7 15.1 1.7 19.1 11.1 24 9 14 305 -7.1 0 -6.7 -7.3 11/07/2005 20:40:00 16.4 2.6 22.1 11.8 16.4 2.7 22.6 11.1 27 12 29 305 -6.9 0.3 -6 -7.5 11/07/2005 20:50:00 14.7 1 17.2 11.5 14.7 1 17.9 11.8 42 7 33 305 -7.4 0 -7.3 -7.7 11/07/2005 21:00:00 13.7 1.3 17.9 11.5 13.7 1.2 17.6 11.1 27 5 35 305 -7.5 0.1 -7.1 -7.7 11/07/2005 21:10:00 13.6 1.7 19.5 10.7 13.5 1.8 20.2 9.5 26 7 39 305 -7 0.2 -6.4 -7.5 11/07/2005 21:20:00 14.3 1.2 16.8 11.5 14.2 1.2 16.8 10.7 32 6 30 305 -7.1 0 -6.9 -7.3 11/07/2005 21:30:00 14 2 18.3 10.7 14 2.1 18.7 10.7 32 6 33 305 -7.4 0.2 -6.9 -7.7 11/07/2005 21:40:00 15.6 1.2 18.7 11.8 15.5 1.3 19.1 11.8 33 5 36 305 -7.1 0.3 -6.7 -7.7 11/07/2005 21:50:00 15.5 1.6 19.9 11.5 15.3 1.6 20.6 11.1 31 7 24 305 -6.6 0.2 -6.2 -7.1 11/07/2005 22:00:00 15.9 1.3 19.5 12.2 15.7 1.3 19.1 12.6 29 6 28 305 -6.5 0.1 -6.2 -6.9 11/07/2005 22:10:00 15.9 1.2 19.1 12.6 15.9 1.3 19.5 13 21 6 15 305 -6.6 0 -6.2 -7.1 11/07/2005 22:20:00 16.3 1.9 20.6 9.9 16.1 1.7 20.6 10.3 20 9 10 305 -7.1 0.2 -6.7 -7.5 11/07/2005 22:30:00 17 3.2 25.6 11.5 16.8 2.9 24 11.5 27 8 12 305 -6.9 0.2 -6.2 -7.3 11/07/2005 22:40:00 18.5 2.2 22.1 13.3 18.4 2.2 22.1 13 27 6 19 305 -7 0.3 -6.2 -7.5 11/07/2005 22:50:00 16.8 1.4 20.6 13 16.7 1.5 20.6 13.3 23 10 13 305 -6.5 0.2 -6 -6.9 11/07/2005 23:00:00 17.7 2 22.6 13 17.8 2.1 22.1 13.3 7 5 5 305 -6.3 0.1 -6 -6.7 11/07/2005 23:10:00 17.6 2.1 22.9 12.6 17.4 2.1 23.3 12.2 21 9 24 305 -6.3 0.2 -5.8 -6.7 11/07/2005 23:20:00 19 1.7 22.6 14.9 18.9 1.9 22.6 14.5 16 6 21 305 -6.3 0.2 -5.8 -6.9 11/07/2005 23:30:00 17.3 1.5 21.8 12.6 17.4 1.6 21.8 12.2 15 5 15 305 -6.4 0.4 -5.6 -6.9 11/07/2005 23:40:00 18.4 1.3 21.8 14.1 18.5 1.3 21.8 14.5 9 6 12 305 -5.9 0 -5.6 -6.2 11/07/2005 23:50:00 19.4 1.5 22.6 14.5 19.5 1.7 23.3 14.5 9 5 8 305 -6.3 0.1 -6 -6.7 11/08/2005 00:00:00 18.6 1.6 23.3 14.9 18.5 1.7 23.7 13.7 13 6 12 305 -6 0.2 -5.6 -6.7 11/08/2005 00:10:00 19.3 1.6 23.3 15.3 19.3 1.6 22.6 15.3 10 5 16 305 -6.1 0.2 -5.6 -6.7 11/08/2005 00:20:00 18.8 2 22.9 12.2 18.7 2 23.3 12.2 13 5 17 305 -5.9 0.1 -5.6 -6.2 11/08/2005 00:30:00 18.2 1.7 21.8 14.1 18.1 1.7 21.8 13.7 11 8 11 305 -6.2 0.4 -5.6 -6.7 11/08/2005 00:40:00 18 1.7 22.9 14.1 18 1.8 22.9 13.3 9 8 3 305 -5.9 0.1 -5.6 -6.2 11/08/2005 00:50:00 19.1 1.6 22.1 13 19.1 1.6 22.6 14.1 6 9 356 305 -6.2 0.2 -5.8 -6.7 11/08/2005 01:00:00 18.7 1.9 23.3 13.7 18.5 2.1 22.9 12.2 15 7 12 305 -6.3 0.2 -5.8 -6.7 11/08/2005 01:10:00 19.5 2 24.8 14.1 19.4 2 24 15.3 6 6 18 305 -5.8 0.1 -5.6 -6.2 11/08/2005 01:20:00 20 2.1 24.4 14.5 19.9 2 24.8 14.5 4 5 359 305 -6.4 0.3 -5.6 -6.9 11/08/2005 01:30:00 19.9 1.7 23.3 14.5 19.8 1.7 23.3 15.3 10 7 5 305 -6.4 0.1 -6 -6.9 11/08/2005 01:40:00 20.2 2.4 25.2 14.5 20.1 2.4 25.6 14.1 9 5 1 305 -6.2 0.2 -5.8 -6.7 11/08/2005 01:50:00 20.4 1.8 24.4 16.1 20.2 1.9 24 16.1 11 5 11 305 -6.1 0 -5.8 -6.2 11/08/2005 02:00:00 20.9 1.9 24.8 16.1 20.9 1.9 25.2 16.1 6 7 359 305 -6.1 0 -5.8 -6.4 11/08/2005 02:10:00 20.6 1.5 24.8 16.4 20.5 1.6 24.8 16.4 7 5 8 305 -6.3 0.1 -5.8 -6.7 11/08/2005 02:20:00 20.7 1.7 25.2 16.1 20.6 1.7 24.8 15.3 9 5 13 305 -6.1 0.2 -5.6 -6.7 11/08/2005 02:30:00 21.2 1.7 25.6 15.6 20.9 1.9 26 15.3 8 6 11 305 -6.2 0 -5.8 -6.4 11/08/2005 02:40:00 21.7 1.7 26 16.4 21.4 1.8 26.3 16.8 10 4 10 305 -6.1 0 -5.8 -6.7 11/08/2005 02:50:00 21.6 2 26.3 16.4 21.6 2 26 16.4 12 5 8 305 -6.1 0.1 -5.8 -6.4 11/08/2005 03:00:00 22.5 1.7 27.1 16.8 22.2 1.7 26.3 16.1 7 4 13 305 -6.1 0.1 -5.6 -6.2 11/08/2005 03:10:00 22.4 2 26.8 17.2 22.3 2 26.8 16.8 8 5 9 305 -5.7 0.1 -5.6 -6 11/08/2005 03:20:00 23.4 1.7 27.1 18.3 23.1 1.8 27.1 17.6 5 5 5 305 -5.9 0.1 -5.6 -6 11/08/2005 03:30:00 21.7 2.2 26.8 16.4 21.6 2.3 26.8 16.4 5 5 6 305 -5.6 0 -5.1 -5.8 11/08/2005 03:40:00 22.5 1.8 26.3 17.2 22.3 1.9 26.3 17.2 8 4 1 305 -5.8 0.1 -5.3 -6 11/08/2005 03:50:00 22.1 2 26.8 16.8 22 2 26.8 16.1 10 5 15 305 -5.5 0.1 -5.1 -5.8 11/08/2005 04:00:00 22 2.1 26.8 16.8 21.9 2.1 26.8 15.6 7 6 9 305 -5.5 0.1 -5.1 -5.8 11/08/2005 04:10:00 21.7 2.2 27.1 15.6 21.4 2.4 26.3 14.9 6 6 3 305 -5.5 0.1 -5.1 -6 11/08/2005 04:20:00 22.8 2.5 27.9 17.2 22.7 2.5 27.9 16.4 4 5 6 305 -5.5 0.2 -5.1 -5.8 11/08/2005 04:30:00 23.8 2.4 28.3 17.6 23.5 2.3 27.9 17.2 7 6 18 305 -5.4 0.1 -5.1 -5.8 11/08/2005 04:40:00 23.5 2.3 29.1 17.6 23.2 2.2 28.7 17.2 6 5 14 305 -5.6 0.1 -5.1 -5.8 11/08/2005 04:50:00 23.2 2.3 27.5 16.1 23.1 2.3 29.1 17.2 5 5 5 305 -5.5 0.1 -5.1 -5.8 11/08/2005 05:00:00 23.7 2.2 29.1 17.2 23.6 2.2 29.1 17.9 3 4 1 305 -5.5 0 -5.1 -5.6 11/08/2005 05:10:00 23.8 1.7 28.3 19.5 23.6 1.7 27.9 18.3 6 6 4 305 -5.4 0.1 -4.9 -5.6 11/08/2005 05:20:00 23.7 2.3 28.3 17.9 23.5 2.2 28.7 17.9 8 5 1 305 -5.5 0.2 -4.9 -6 11/08/2005 05:30:00 23.9 2 29.1 18.3 23.6 2.1 28.3 18.7 5 6 0 305 -5.5 0 -5.1 -5.8 11/08/2005 05:40:00 24 2.8 29.4 16.4 23.6 2.8 28.7 16.1 5 5 3 305 -5.4 0.1 -4.9 -5.8 11/08/2005 05:50:00 23 1.9 27.1 16.8 22.8 2 26.8 17.6 4 5 3 305 -5.5 0 -5.1 -5.6 11/08/2005 06:00:00 23.2 2.1 28.7 17.2 23 2.2 28.7 16.8 9 6 11 305 -5.4 0.2 -4.9 -5.8 11/08/2005 06:10:00 24.4 2.1 30.2 18.3 24 2.1 29.8 16.8 8 6 14 305 -5.7 0.1 -5.3 -6 11/08/2005 06:20:00 23.9 2.2 29.8 17.6 23.5 2.2 29.8 17.6 9 5 10 305 -5.6 0.2 -5.1 -6.2 11/08/2005 06:30:00 22.9 2.4 27.9 17.6 22.7 2.4 28.3 17.2 8 6 4 305 -5.7 0.2 -5.3 -6.2 11/08/2005 06:40:00 22.7 1.8 27.9 18.3 22.5 2 27.9 17.2 9 5 5 305 -5.6 0.1 -5.1 -6 11/08/2005 06:50:00 22.1 2.2 26.8 15.3 21.8 2.3 26.3 14.9 9 5 12 305 -5.8 0.1 -5.6 -6 11/08/2005 07:00:00 22.4 2.1 26.8 17.2 22 2.2 26.8 16.8 9 5 3 305 -5.7 0.1 -5.3 -6.2 11/08/2005 07:10:00 22.7 1.9 27.9 16.8 22.3 1.9 27.9 17.6 9 5 9 305 -5.7 0 -5.6 -5.8 11/08/2005 07:20:00 23.2 2 27.9 18.3 22.8 2 27.9 17.9 11 5 4 305 -5.7 0.1 -5.6 -6 11/08/2005 07:30:00 22.2 2.4 27.5 15.6 21.7 2.6 27.5 15.3 15 5 14 305 -5.5 0.1 -4.9 -5.8 11/08/2005 07:40:00 23.7 2.1 28.3 17.6 23.3 2.1 27.9 17.2 7 5 5 305 -5.4 0.1 -4.9 -5.6 11/08/2005 07:50:00 22.9 2 26.8 17.9 22.4 2.1 26.8 16.8 9 5 6 305 -5.3 0.1 -5.1 -5.6 11/08/2005 08:00:00 22.6 2.1 27.5 17.2 22.2 2.2 27.1 17.2 11 6 17 305 -5.2 0 -5.1 -5.6 11/08/2005 08:10:00 23.1 2.2 28.3 17.9 22.6 2.1 27.9 18.3 9 6 11 305 -5.2 0.1 -4.9 -5.6 11/08/2005 08:20:00 23.9 1.9 28.3 18.3 23.1 1.9 27.9 18.7 8 5 7 305 -5.3 0 -5.1 -5.6 11/08/2005 08:30:00 24.2 2.1 28.7 18.7 23.5 1.9 28.7 18.3 6 5 4 305 -5.4 0 -5.1 -5.6 11/08/2005 08:40:00 25 1.8 30.6 19.9 23.9 1.9 29.4 18.3 8 5 9 305 -5.3 0 -5.1 -5.6 11/08/2005 08:50:00 25.3 2.3 30.6 18.7 24.4 2.3 29.8 18.7 10 5 13 305 -5.4 0.1 -5.1 -5.8 11/08/2005 09:00:00 24 2.2 28.3 17.6 23.2 2.3 27.9 17.6 9 6 3 305 -5.5 0 -5.1 -5.8 11/08/2005 09:10:00 25.3 1.8 29.1 20.2 24.4 1.8 28.7 19.9 11 4 18 305 -5.7 0.2 -5.3 -6 11/08/2005 09:20:00 24.4 2 28.7 18.3 23.6 2.1 27.9 17.9 12 4 12 305 -5.7 0.1 -5.6 -6 11/08/2005 09:30:00 23.8 1.8 28.7 18.7 22.9 2 27.9 18.3 12 4 17 305 -5.6 0.1 -5.1 -6 11/08/2005 09:40:00 22.8 1.7 27.1 17.2 21.9 1.9 26.3 16.4 15 6 16 305 -5.4 0.1 -5.1 -5.8 11/08/2005 09:50:00 22.6 1.8 26.8 17.9 21.9 1.9 26.8 17.9 12 5 8 305 -5.3 0.1 -4.9 -5.6 11/08/2005 10:00:00 22.5 1.8 27.1 17.9 21.7 1.9 26.3 16.8 14 6 8 305 -5.5 0 -5.1 -5.8 11/08/2005 10:10:00 22 1.7 27.1 17.9 21.1 1.8 26.8 16.8 17 5 18 305 -5.4 0 -5.1 -5.6 11/08/2005 10:20:00 22.9 2 26.8 17.9 22 2.1 26.3 16.8 14 5 10 305 -5.4 0.1 -5.1 -5.8 11/08/2005 10:30:00 22.5 2.1 27.5 16.4 21.8 2 26.8 16.8 12 5 19 305 -5.3 0.1 -5.1 -5.6 11/08/2005 10:40:00 22.5 2.1 27.9 17.6 21.9 2.1 27.5 16.4 10 6 5 305 -5.2 0.1 -4.9 -5.6 11/08/2005 10:50:00 23.2 2.2 27.9 17.2 22.6 2.3 27.9 16.1 10 5 6 305 -5.2 0.1 -5.1 -5.6 11/08/2005 11:00:00 22.6 1.7 27.5 17.6 22.1 1.8 27.1 16.4 13 5 14 305 -5.2 0 -4.9 -5.6 11/08/2005 11:10:00 22.4 2.2 27.9 16.4 22 2.2 27.1 15.6 12 5 13 305 -5.1 0.1 -4.7 -5.6 11/08/2005 11:20:00 22.8 2.3 27.1 16.8 22.6 2.3 27.1 16.8 7 4 11 305 -5.3 0.1 -4.9 -5.6 11/08/2005 11:30:00 22.2 2.3 27.1 15.3 22 2.4 27.9 16.4 7 5 5 305 -5.3 0 -4.9 -5.6 11/08/2005 11:40:00 22.8 2.2 27.5 16.8 22.4 2.3 26.8 16.4 9 5 11 305 -5.2 0 -4.9 -5.6 11/08/2005 11:50:00 24.9 1.9 28.7 19.5 24.1 1.9 27.9 19.1 14 5 12 305 -5.1 0 -4.9 -5.3 11/08/2005 12:00:00 26.7 2.4 31.8 20.2 25.3 2.4 30.9 18.7 20 5 17 305 -5.2 0 -4.9 -5.6 11/08/2005 12:10:00 25.5 2.3 31.8 20.2 24.2 2.2 29.8 18.7 21 5 23 305 -5.1 0 -4.9 -5.3 11/08/2005 12:20:00 21.4 2.2 26.3 15.3 20.5 2.2 26 14.1 12 9 25 305 -5 0 -4.7 -5.1 11/08/2005 12:30:00 22.1 2.2 26.3 15.6 21.3 2.2 25.6 15.6 4 5 3 305 -5.1 0 -4.7 -5.3 11/08/2005 12:40:00 24.4 2.1 29.8 17.2 23.4 2.1 29.1 17.2 14 5 17 305 -5 0 -4.7 -5.3 11/08/2005 12:50:00 25.3 2.2 30.2 18.7 24.3 2.4 30.6 17.6 14 5 18 305 -5 0 -4.7 -5.1 11/08/2005 13:00:00 23.5 2.2 27.9 18.7 22.8 2.4 28.7 15.6 12 5 12 305 -4.9 0 -4.7 -5.1 11/08/2005 13:10:00 23.1 2 27.9 18.3 22.5 2 27.1 16.4 6 5 358 305 -5 0 -4.9 -5.1 11/08/2005 13:20:00 23.8 2.3 27.9 16.1 23.1 2.4 27.9 14.5 10 6 5 305 -5 0 -4.7 -5.1 11/08/2005 13:30:00 23.9 2.4 29.1 16.8 23.3 2.5 28.7 17.2 11 5 19 305 -5 0.1 -4.7 -5.1 11/08/2005 13:40:00 24.6 2.4 29.8 18.3 24.2 2.5 29.4 17.9 10 5 7 305 -5 0 -4.7 -5.1 11/08/2005 13:50:00 24.4 2.5 29.8 17.9 23.9 2.6 29.8 17.9 11 5 11 305 -4.9 0 -4.7 -5.1 11/08/2005 14:00:00 24.9 1.9 30.2 18.3 24.6 2 29.4 17.6 9 5 10 305 -4.9 0 -4.7 -5.1 11/08/2005 14:10:00 23.6 2.2 28.7 17.6 23.3 2.4 28.7 17.9 7 5 4 305 -4.9 0 -4.7 -4.9 11/08/2005 14:20:00 23.2 2.2 28.3 17.6 22.9 2.3 28.3 17.2 8 5 5 305 -4.9 0 -4.7 -4.9 11/08/2005 14:30:00 23.5 2.2 29.4 17.6 23.4 2.3 29.1 17.9 7 6 16 305 -4.8 0 -4.7 -4.9 11/08/2005 14:40:00 24.2 1.7 29.8 19.5 24.1 1.9 29.8 19.1 10 5 9 305 -4.8 0 -4.7 -4.9 11/08/2005 14:50:00 23 2.4 29.1 16.4 22.9 2.4 28.7 17.6 5 5 8 305 -4.8 0 -4.7 -4.9 11/08/2005 15:00:00 25.6 2.4 31.3 17.6 25.4 2.5 31.8 15.6 10 6 12 305 -4.8 0 -4.7 -4.9 11/08/2005 15:10:00 24.9 2.1 29.4 18.3 24.7 2.1 29.4 18.3 11 4 10 305 -4.8 0 -4.7 -4.9 11/08/2005 15:20:00 25.2 2.4 30.6 19.1 25.1 2.5 29.8 18.7 8 5 11 305 -4.7 0 -4.5 -4.9 11/08/2005 15:30:00 24.5 2.7 30.2 18.3 24.3 2.8 29.8 17.6 12 5 17 305 -4.7 0.1 -4.5 -4.9 11/08/2005 15:40:00 24 2.3 29.4 18.3 23.5 2.4 27.9 17.2 13 5 12 305 -4.6 0 -4.5 -4.7 11/08/2005 15:50:00 24.3 1.7 27.9 19.9 24.1 1.8 28.7 18.7 9 6 10 305 -4.6 0 -4.5 -4.7 11/08/2005 16:00:00 23.7 2.4 29.4 17.2 23.5 2.4 29.1 17.9 8 5 2 305 -4.7 0 -4.5 -4.9 11/08/2005 16:10:00 24.2 2 28.7 18.7 24 2.3 29.8 17.6 7 6 1 305 -4.7 0 -4.5 -4.9 11/08/2005 16:20:00 22.8 2.3 28.3 16.8 22.7 2.4 28.7 17.6 6 5 5 305 -4.7 0 -4.5 -4.9 11/08/2005 16:30:00 23 2 27.9 17.6 22.9 2 27.9 17.2 4 6 6 305 -4.7 0 -4.5 -4.9 11/08/2005 16:40:00 23.7 2 28.3 17.2 23.6 2.2 28.3 17.9 4 6 5 305 -4.7 0 -4.5 -4.9 11/08/2005 16:50:00 21.5 2.4 26.8 15.3 21.5 2.4 26.3 15.3 5 6 2 305 -4.6 0 -4.5 -4.7 11/08/2005 17:00:00 23.1 2.1 27.9 15.6 23 2.3 28.3 15.6 6 6 8 305 -4.8 0 -4.5 -4.9 11/08/2005 17:10:00 22.2 2.3 27.9 16.1 22 2.3 28.3 16.1 7 5 14 305 -4.8 0 -4.5 -4.9 11/08/2005 17:20:00 22.6 2.5 29.1 15.3 22.4 2.6 29.1 14.9 4 5 0 305 -4.8 0 -4.5 -4.9 11/08/2005 17:30:00 23.8 2.1 28.7 17.6 23.7 2.4 29.1 17.2 4 6 357 305 -4.9 0 -4.7 -5.1 11/08/2005 17:40:00 22.9 2 26.8 17.2 22.9 2.2 27.5 16.8 7 6 3 305 -4.9 0 -4.7 -5.1 11/08/2005 17:50:00 22.1 2.5 27.9 15.3 22.2 2.5 29.1 16.4 9 5 5 305 -4.7 0 -4.5 -4.9 11/08/2005 18:00:00 22.7 2.3 27.5 14.9 22.5 2.4 27.9 16.1 9 5 1 305 -4.8 0 -4.7 -4.9 11/08/2005 18:10:00 23 2.5 28.7 16.1 23.1 2.5 29.4 16.8 7 5 7 305 -4.7 0.1 -4.5 -4.9 11/08/2005 18:20:00 23.5 2 28.3 18.3 23.5 2 29.1 18.3 6 5 3 305 -4.8 0 -4.7 -4.9 11/08/2005 18:30:00 22.7 2.1 27.9 17.2 22.6 2.1 29.1 16.8 2 6 3 305 -4.7 0 -4.7 -4.9 11/08/2005 18:40:00 23.6 2.3 29.4 17.9 23.4 2.5 29.4 16.4 4 5 5 305 -4.7 0 -4.5 -4.9 11/08/2005 18:50:00 23.1 2.1 27.9 17.9 23 2.2 27.5 17.6 5 5 357 305 -4.6 0 -4.5 -4.9 11/08/2005 19:00:00 24 2.2 29.1 18.3 23.6 2.3 29.1 17.9 11 5 2 305 -4.7 0.1 -4.5 -4.9 11/08/2005 19:10:00 24.6 2.4 28.7 17.2 24.4 2.4 28.7 17.6 10 5 10 305 -4.6 0 -4.5 -4.7 11/08/2005 19:20:00 23.6 2 29.1 17.6 23.7 2 28.7 18.3 7 5 7 305 -4.5 0 -4.5 -4.7 11/08/2005 19:30:00 23.7 1.9 28.3 17.6 23.7 2 27.9 17.6 5 5 10 305 -4.7 0 -4.5 -4.9 11/08/2005 19:40:00 23.2 2.1 29.8 18.3 23 2.3 30.2 17.6 14 7 2 305 -4.6 0 -4.5 -4.7 11/08/2005 19:50:00 23.2 2.1 28.3 17.2 22.9 2.1 27.9 16.1 12 5 13 305 -4.6 0.1 -4.5 -4.9 11/08/2005 20:00:00 22.8 2.1 26.8 17.2 22.7 2.2 27.5 17.2 11 5 8 305 -4.6 0.1 -4.5 -4.9 11/08/2005 20:10:00 22.5 2.1 27.9 16.8 22.4 2.1 27.9 17.2 11 6 15 305 -4.6 0 -4.2 -4.7 11/08/2005 20:20:00 22.8 2.3 27.5 17.2 22.8 2.4 27.9 15.6 11 6 11 305 -4.5 0 -4.2 -4.7 11/08/2005 20:30:00 22.3 2.3 28.7 16.8 22.1 2.3 28.3 16.4 11 6 14 305 -4.5 0 -4.5 -4.7 11/08/2005 20:40:00 23.6 2.4 29.1 17.9 23.4 2.5 28.7 17.2 6 5 1 305 -4.6 0.1 -4.5 -4.9 11/08/2005 20:50:00 23.1 2.3 28.3 17.6 23 2.4 28.7 16.4 4 5 12 305 -4.7 0 -4.5 -4.9 11/08/2005 21:00:00 23.8 1.8 28.3 17.9 23.7 2 29.1 17.6 6 4 8 305 -4.7 0 -4.5 -4.7 11/08/2005 21:10:00 22.4 2.4 27.5 15.6 22.3 2.4 27.5 15.3 7 5 4 305 -4.5 0.1 -4.2 -4.7 11/08/2005 21:20:00 23.6 2.1 28.3 17.6 23.4 2.2 28.3 17.2 10 4 10 305 -4.6 0 -4.5 -4.7 11/08/2005 21:30:00 23.3 2.3 27.9 17.2 23.1 2.3 27.9 17.2 7 6 12 305 -4.5 0 -4.5 -4.7 11/08/2005 21:40:00 21.8 2.3 28.3 15.6 21.8 2.3 28.7 15.6 7 6 4 305 -4.4 0 -4.2 -4.7 11/08/2005 21:50:00 23.1 2 27.9 17.2 23 2.2 27.5 17.2 5 5 7 305 -4.4 0 -4.2 -4.7 11/08/2005 22:00:00 23.4 1.8 27.9 16.4 23.5 1.8 28.7 17.6 3 4 356 305 -4.4 0 -4.2 -4.7 11/08/2005 22:10:00 23.7 1.8 28.3 18.7 23.5 1.8 27.9 18.3 7 5 7 305 -4.5 0 -4.2 -4.7 11/08/2005 22:20:00 24.4 1.8 28.3 18.3 24.3 2 29.1 18.3 10 5 8 305 -4.6 0 -4.2 -4.7 11/08/2005 22:30:00 22.2 2.2 28.3 17.6 22.1 2.2 27.9 17.2 7 5 9 305 -4.4 0 -4 -4.7 11/08/2005 22:40:00 23.9 1.8 27.9 18.3 23.9 2.1 27.9 17.6 4 5 0 305 -4.6 0 -4.5 -4.9 11/08/2005 22:50:00 21.8 1.9 26 16.1 21.7 2 26 16.4 4 5 356 305 -4.4 0.1 -4 -4.7 11/08/2005 23:00:00 21.5 2.3 27.9 15.6 21.3 2.4 28.7 16.1 8 6 0 305 -4.2 0.1 -4 -4.5 11/08/2005 23:10:00 21.2 1.8 26.3 16.8 21.2 1.9 26.8 16.1 6 5 11 305 -4.1 0 -3.8 -4.5 11/08/2005 23:20:00 22.6 2 27.9 17.2 22.6 2.1 28.7 16.8 4 5 8 305 -4.5 0.1 -4 -4.7 11/08/2005 23:30:00 22.6 1.8 26.3 17.6 22.5 2 26.8 16.8 9 6 5 305 -4.6 0.1 -4.5 -4.9 11/08/2005 23:40:00 21.4 2.9 27.9 15.3 21.3 3.1 28.3 15.3 11 5 18 305 -4.3 0.1 -3.8 -4.7 11/08/2005 23:50:00 21.9 2.1 26.3 15.6 21.7 2.3 26.3 15.6 10 5 10 305 -4.2 0.1 -4 -4.5 11/09/2005 00:00:00 21.8 2.1 26.8 16.8 21.7 2.2 26.8 16.4 9 4 10 305 -4.2 0.1 -3.8 -4.5 11/09/2005 00:10:00 21.1 2.2 26 14.9 21 2.3 26 15.3 9 4 11 305 -4.2 0.1 -3.8 -4.5 11/09/2005 00:20:00 22.1 2.1 26.3 17.2 22 2.1 27.1 16.4 9 6 18 305 -4.2 0.1 -3.8 -4.5 11/09/2005 00:30:00 21.7 2.4 26.8 15.6 21.4 2.5 27.5 15.6 9 5 9 305 -4.3 0.1 -4 -4.5 11/09/2005 00:40:00 21.5 2 25.6 16.4 21.5 2.1 26.8 16.1 7 6 21 305 -4.2 0.1 -4 -4.5 11/09/2005 00:50:00 21.6 2 26.3 16.1 21.5 2.1 26 16.1 8 5 15 305 -4.4 0 -4 -4.7 11/09/2005 01:00:00 22 1.9 26.8 17.2 22 1.9 26.8 16.1 3 5 9 305 -4.5 0.1 -4.2 -4.7 11/09/2005 01:10:00 21.2 1.9 26.3 16.1 21.2 2 26 16.4 1 5 4 305 -4.2 0.1 -4 -4.5 11/09/2005 01:20:00 21.8 2.2 26.8 15.3 21.8 2.3 26.8 15.6 2 5 357 305 -4.2 0.1 -4 -4.5 11/09/2005 01:30:00 23 1.9 27.1 16.8 22.9 2 27.5 17.6 6 5 12 305 -4.2 0 -4 -4.5 11/09/2005 01:40:00 21.9 1.8 25.6 17.2 21.9 1.9 26 16.4 1 6 2 305 -4.2 0 -4 -4.5 11/09/2005 01:50:00 21.9 1.9 27.5 16.8 21.8 1.9 27.5 16.8 5 5 9 305 -4.2 0.1 -3.8 -4.5 11/09/2005 02:00:00 21.7 1.9 26.8 17.2 21.7 2 26.8 16.8 4 6 6 305 -4.2 0.1 -4 -4.5 11/09/2005 02:10:00 20.3 2.1 26 14.1 20.3 2.2 26.8 13.7 5 5 5 305 -4.1 0.1 -3.8 -4.5 11/09/2005 02:20:00 21.8 1.7 26.3 17.2 21.7 1.7 26 16.1 1 5 2 305 -4.4 0 -4 -4.7 11/09/2005 02:30:00 21.2 1.9 26 15.6 21.3 2 26.3 16.4 2 6 8 305 -4.4 0 -4 -4.5 11/09/2005 02:40:00 21.5 1.9 25.6 16.1 21.6 1.9 26 16.4 4 5 7 305 -4.5 0 -4.2 -4.7 11/09/2005 02:50:00 20.8 2 25.2 15.3 20.7 1.9 25.2 15.6 5 7 0 305 -4.5 0.1 -4 -4.7 11/09/2005 03:00:00 19.7 2 24 15.3 19.7 2.1 24 15.3 3 5 2 305 -4.4 0 -4.2 -4.7 11/09/2005 03:10:00 20.3 2 24.4 14.1 20.2 2 24 14.5 6 5 10 305 -4.4 0 -4.2 -4.5 11/09/2005 03:20:00 21.2 2.1 25.6 16.4 21.2 2.1 26.3 16.4 6 5 7 305 -4.4 0 -4.2 -4.7 11/09/2005 03:30:00 21.2 2.1 25.2 14.9 21.1 2.2 25.2 15.3 5 5 8 305 -4.4 0 -4 -4.7 11/09/2005 03:40:00 22.3 1.8 26.3 17.9 22.2 2 27.1 16.4 4 6 7 305 -4.6 0.1 -4.5 -4.9 11/09/2005 03:50:00 21.3 1.7 25.2 15.3 21.3 1.8 25.6 15.3 4 5 5 305 -4.6 0 -4.5 -4.7 11/09/2005 04:00:00 19.9 2.2 24.4 14.1 19.7 2.2 24.8 14.1 3 6 3 305 -4.4 0 -4 -4.7 11/09/2005 04:10:00 21.4 1.8 25.2 16.4 21.5 2 25.6 16.4 357 5 1 305 -4.6 0 -4.2 -4.7 11/09/2005 04:20:00 21.4 2.1 26.3 16.4 21.5 2.3 26.8 15.6 4 6 354 305 -4.5 0.1 -4.2 -4.7 11/09/2005 04:30:00 21.4 1.7 25.2 16.4 21.4 1.8 24.8 16.4 7 5 6 305 -4.5 0 -4.2 -4.7 11/09/2005 04:40:00 21.8 2.4 27.5 16.4 21.7 2.6 27.9 15.3 8 5 8 305 -4.6 0.2 -4.2 -4.9 11/09/2005 04:50:00 22.4 1.9 27.9 17.2 22.5 2 27.9 16.4 3 5 359 305 -4.7 0 -4.5 -4.9 11/09/2005 05:00:00 22.6 1.6 27.5 17.9 22.7 1.7 28.3 18.3 3 5 351 305 -4.6 0 -4.5 -4.9 11/09/2005 05:10:00 22.1 1.8 26 17.2 22 1.8 26.3 17.2 5 6 12 305 -4.6 0 -4.5 -4.7 11/09/2005 05:20:00 22.4 1.9 26.3 17.2 22.2 2.1 27.1 16.8 8 6 10 305 -4.7 0.1 -4.5 -4.9 11/09/2005 05:30:00 22.4 2 26.3 16.1 22.2 2.1 26.3 16.4 6 5 9 305 -4.6 0 -4.5 -4.9 11/09/2005 05:40:00 22.3 1.8 26 16.8 22.3 1.9 26.8 17.6 8 5 1 305 -4.6 0 -4.5 -4.7 11/09/2005 05:50:00 22.3 2.7 27.5 15.6 22.3 2.6 27.9 15.6 5 6 10 305 -4.6 0.1 -4.2 -4.9 11/09/2005 06:00:00 23.5 1.8 27.1 17.9 23.3 1.9 27.1 16.4 4 5 0 305 -4.7 0.1 -4.5 -4.9 11/09/2005 06:10:00 22.2 2.3 27.9 15.3 22 2.2 27.9 16.4 6 5 6 305 -4.6 0.1 -4.5 -4.9 11/09/2005 06:20:00 21.9 2 26.3 16.4 21.9 2.1 26.3 16.1 5 5 3 305 -4.7 0 -4.5 -4.9 11/09/2005 06:30:00 21.9 1.7 25.6 16.8 21.7 1.8 26.8 16.4 7 5 3 305 -4.7 0.1 -4.5 -4.9 11/09/2005 06:40:00 21.6 1.9 25.6 16.8 21.4 2 25.2 16.4 8 5 9 305 -4.7 0 -4.5 -4.9 11/09/2005 06:50:00 21.3 2.1 25.6 16.4 21.2 2.2 26 16.1 4 5 4 305 -4.5 0.1 -4.2 -4.9 11/09/2005 07:00:00 21.9 2.3 26.8 16.1 21.9 2.3 27.1 16.4 1 5 4 305 -4.6 0 -4.5 -4.9 11/09/2005 07:10:00 22.2 2.1 27.1 16.1 22.1 2.2 27.5 16.8 3 4 9 305 -4.7 0 -4.5 -4.7 11/09/2005 07:20:00 21.7 2.2 26.3 15.6 21.9 2.2 26.8 16.4 2 5 358 305 -4.5 0.1 -4 -4.7 11/09/2005 07:30:00 21.9 1.9 25.6 16.4 21.8 2 26.8 16.4 3 5 5 305 -4.5 0 -4.2 -4.7 11/09/2005 07:40:00 21.9 1.8 26.8 17.2 22 1.8 27.5 17.2 359 5 351 305 -4.5 0 -4.2 -4.7 11/09/2005 07:50:00 21.7 2 25.6 16.4 21.6 2 25.6 16.8 2 4 8 305 -4.4 0 -4 -4.7 11/09/2005 08:00:00 20.5 2 25.6 15.3 20.5 2 26 15.6 2 6 1 305 -4.5 0 -4.2 -4.7 11/09/2005 08:10:00 21.3 1.8 25.2 15.3 21.3 2 25.6 15.6 0 5 5 305 -4.4 0 -4 -4.7 11/09/2005 08:20:00 20.5 2.2 25.2 14.9 20.6 2.2 25.2 14.5 3 5 356 305 -4.3 0.1 -3.8 -4.7 11/09/2005 08:30:00 21.7 2.2 26.8 16.4 21.7 2.2 26.8 16.8 2 5 359 305 -4.4 0.1 -4 -4.7 11/09/2005 08:40:00 22.1 1.8 27.1 17.6 22 2.1 27.1 16.4 4 5 0 305 -4.3 0 -4 -4.5 11/09/2005 08:50:00 21.6 2.3 26.3 15.6 21.5 2.4 27.1 15.3 10 5 4 305 -4.3 0 -4 -4.5 11/09/2005 09:00:00 22.1 2.1 27.1 16.4 21.9 2.2 27.1 16.4 9 5 12 305 -4.2 0.1 -3.8 -4.5 11/09/2005 09:10:00 22.4 2.5 27.5 15.6 22.2 2.5 28.7 14.9 10 4 12 305 -4.2 0.1 -3.8 -4.5 11/09/2005 09:20:00 21.5 2 26 15.6 21.3 2.1 25.6 15.3 11 5 9 305 -4.1 0 -3.8 -4.2 11/09/2005 09:30:00 22.2 1.8 26.3 17.6 21.9 1.7 26.3 16.8 13 5 18 305 -4 0.1 -3.8 -4.2 11/09/2005 09:40:00 21.6 2.3 27.5 16.1 21.5 2.5 27.1 15.6 8 5 8 305 -4 0.1 -3.6 -4.2 11/09/2005 09:50:00 21.4 2.2 26.3 14.9 21.1 2.4 26.8 15.3 8 6 8 305 -4.1 0 -3.8 -4.2 11/09/2005 10:00:00 22.2 2 26 16.8 21.9 2 26 16.1 10 5 8 305 -4 0 -3.8 -4.2 11/09/2005 10:10:00 22.4 2 27.1 16.4 22.2 2 26.8 16.1 9 5 7 305 -4 0 -3.8 -4.2 11/09/2005 10:20:00 22.6 1.9 26.3 16.1 22.4 1.9 26.8 16.8 10 6 4 305 -3.9 0 -3.6 -4 11/09/2005 10:30:00 21.3 2.1 26.3 16.1 21 2.2 25.2 16.4 10 5 5 305 -3.7 0 -3.3 -3.8 11/09/2005 10:40:00 20 2 24.4 16.1 19.8 2.1 25.2 14.9 9 5 13 305 -3.6 0 -3.3 -3.8 11/09/2005 10:50:00 21.1 1.8 25.2 16.4 21.2 1.9 25.2 16.8 7 4 9 305 -3.6 0 -3.3 -3.8 11/09/2005 11:00:00 20.9 1.7 25.6 16.4 20.9 1.9 25.6 16.1 4 5 5 305 -3.5 0.1 -3.3 -3.8 11/09/2005 11:10:00 21.8 1.7 25.6 16.4 21.7 1.7 25.6 16.8 5 5 1 305 -3.7 0.1 -3.3 -3.8 11/09/2005 11:20:00 21.2 2 24.8 14.9 21.1 2 25.6 15.6 6 5 11 305 -4.1 0.2 -3.8 -4.5 11/09/2005 11:30:00 20.6 1.8 26.3 15.6 20.5 1.8 25.6 15.6 6 4 6 305 -4 0.2 -3.6 -4.5 11/09/2005 11:40:00 20.4 2.4 25.2 14.1 20.2 2.5 25.6 14.1 8 6 16 305 -3.8 0 -3.3 -4 11/09/2005 11:50:00 21.1 2.2 26.8 15.6 20.9 2.3 27.1 15.6 5 5 11 305 -3.7 0.1 -3.3 -3.8 11/09/2005 12:00:00 21 2.1 26.3 14.5 20.9 2.1 27.1 15.6 9 5 0 305 -3.6 0.1 -3.3 -3.8 11/09/2005 12:10:00 21.8 2.3 27.1 15.6 21.8 2.4 27.5 16.4 7 5 3 305 -3.7 0.1 -3.3 -4 11/09/2005 12:20:00 21.6 1.7 24.8 15.6 21.3 1.9 25.2 16.4 11 6 10 305 -3.8 0 -3.6 -3.8 11/09/2005 12:30:00 21.6 2.3 25.6 15.6 21.6 2.3 26.3 15.6 4 6 6 305 -3.7 0 -3.3 -4 11/09/2005 12:40:00 21.4 2.4 26.8 13.3 21.4 2.5 27.1 14.9 4 5 1 305 -3.9 0 -3.8 -4 11/09/2005 12:50:00 21.5 2.1 26.3 16.1 21.4 2.1 26.3 15.6 7 6 9 305 -3.8 0 -3.3 -4 11/09/2005 13:00:00 22 2.2 27.1 16.8 21.9 2.2 27.1 16.1 10 6 12 305 -3.9 0 -3.6 -4 11/09/2005 13:10:00 23 1.9 27.1 17.6 22.9 2 27.5 16.8 10 4 15 305 -3.9 0 -3.8 -4 11/09/2005 13:20:00 21.8 2.1 26 16.1 21.6 2 26 16.4 7 5 7 305 -3.9 0 -3.8 -4 11/09/2005 13:30:00 21.8 1.9 26 15.6 21.7 2 26 16.1 9 5 8 305 -3.9 0 -3.8 -4 11/09/2005 13:40:00 21 2.3 26 14.9 21 2.3 26 14.9 6 5 7 305 -4 0 -3.8 -4 11/09/2005 13:50:00 21.7 1.9 26 16.8 21.6 2.1 26.8 17.2 10 5 11 305 -4.1 0 -4 -4.2 11/09/2005 14:00:00 21.2 1.8 26 15.6 21.1 1.9 26.3 15.6 5 5 3 305 -4 0 -3.8 -4.2 11/09/2005 14:10:00 21.7 1.7 25.2 16.8 21.7 1.8 26.3 16.1 5 5 4 305 -4.1 0 -3.8 -4.2 11/09/2005 14:20:00 22 2.1 27.1 16.1 22 2.2 27.1 16.1 5 6 7 305 -4.1 0.1 -3.8 -4.5 11/09/2005 14:30:00 21.6 1.8 25.6 17.6 21.6 1.8 25.2 16.8 10 4 7 305 -4.2 0 -3.8 -4.5 11/09/2005 14:40:00 21 1.6 24.8 16.8 20.7 1.7 24.8 16.8 8 6 1 305 -4.2 0 -3.8 -4.5 11/09/2005 14:50:00 21.6 1.9 26.3 15.6 21.6 2 26.8 16.1 6 6 3 305 -4.3 0 -4 -4.5 11/09/2005 15:00:00 21.7 1.7 25.6 17.2 21.5 1.8 25.6 16.8 14 5 17 305 -4.3 0 -4 -4.5 11/09/2005 15:10:00 21.1 2.1 26.8 16.1 21.1 2.1 27.1 16.4 8 6 3 305 -4.2 0.1 -4 -4.5 11/09/2005 15:20:00 22.5 1.8 26.8 17.2 22.4 1.9 27.1 16.8 8 4 7 305 -4.4 0 -4 -4.5 11/09/2005 15:30:00 21.3 2 26.3 16.4 21 2.1 27.1 16.4 8 5 4 305 -4.4 0 -4 -4.5 11/09/2005 15:40:00 21 2.2 26 14.5 20.8 2.3 26.3 14.5 7 6 359 305 -4.2 0.1 -4 -4.5 11/09/2005 15:50:00 21.9 1.7 25.6 16.8 21.7 1.7 25.2 16.8 13 6 17 305 -4.4 0.1 -4 -4.7 11/09/2005 16:00:00 20.7 2.3 26.3 16.1 20.5 2.3 26.3 15.6 14 6 19 305 -4.2 0.1 -3.8 -4.5 11/09/2005 16:10:00 21.2 2.6 27.1 13 21.1 2.6 27.9 13.3 11 4 8 305 -4.2 0.1 -3.8 -4.5 11/09/2005 16:20:00 22.3 1.6 25.6 17.6 22.1 1.7 26 17.2 5 5 8 305 -4.4 0 -3.8 -4.5 11/09/2005 16:30:00 20.7 2.2 25.2 15.6 20.8 2.3 25.6 15.3 9 6 4 305 -4.1 0.1 -3.8 -4.5 11/09/2005 16:40:00 22.4 2 27.1 17.2 22.3 2.1 27.5 16.4 8 5 10 305 -4.3 0.1 -4 -4.5 11/09/2005 16:50:00 21.8 2.4 26.8 15.6 21.6 2.5 27.9 16.4 7 6 358 305 -4.1 0.1 -3.8 -4.5 11/09/2005 17:00:00 22.5 2.6 27.5 16.1 22.1 2.7 27.1 15.3 12 6 7 305 -4.2 0.1 -3.8 -4.5 11/09/2005 17:10:00 22.9 2.1 27.1 17.2 22.8 2.2 27.5 17.6 12 5 9 305 -4.2 0.1 -3.8 -4.5 11/09/2005 17:20:00 23.2 1.9 27.5 18.3 22.9 2.1 27.1 17.2 13 6 12 305 -4.2 0 -4 -4.5 11/09/2005 17:30:00 22.8 2 27.1 16.8 22.6 2 26.8 17.6 8 6 358 305 -4.2 0 -3.8 -4.5 11/09/2005 17:40:00 22.9 2.2 27.1 16.8 22.6 2.3 27.5 16.8 11 5 13 305 -4.1 0.1 -3.8 -4.5 11/09/2005 17:50:00 23.1 1.9 26.8 18.7 22.9 2 27.1 17.2 16 5 17 305 -4.1 0 -3.8 -4.5 11/09/2005 18:00:00 22.7 2.1 27.1 16.8 22.7 2.2 27.1 17.2 10 6 2 305 -3.9 0 -3.6 -4 11/09/2005 18:10:00 23.2 2.1 27.5 16.8 22.9 2.2 27.5 16.4 7 5 359 305 -3.9 0 -3.8 -4.2 11/09/2005 18:20:00 20.6 2.6 26 14.5 20.4 2.6 26 14.1 10 5 7 305 -3.8 0.1 -3.3 -4 11/09/2005 18:30:00 22.8 2.2 26.8 16.8 22.6 2.3 27.5 16.1 10 5 13 305 -3.9 0 -3.6 -4 11/09/2005 18:40:00 22 1.7 26 17.2 21.8 1.9 25.6 16.8 7 5 8 305 -3.8 0 -3.6 -4 11/09/2005 18:50:00 21.7 2 26.8 16.4 21.5 2.1 26.8 16.4 5 6 3 305 -3.9 0 -3.3 -4 11/09/2005 19:00:00 21.9 1.8 26.3 16.4 21.7 1.9 26.3 16.8 5 5 2 305 -3.9 0 -3.8 -4 11/09/2005 19:10:00 21.5 2.3 27.1 14.5 21.3 2.4 27.5 15.3 7 5 10 305 -3.9 0 -3.3 -4 11/09/2005 19:20:00 21.2 2.5 27.9 16.4 21 2.6 28.3 14.9 4 5 6 305 -3.7 0.1 -3.3 -4 11/09/2005 19:30:00 21.7 1.9 26.3 15.6 21.6 2 26.3 16.1 5 5 5 305 -3.9 0 -3.3 -4 11/09/2005 19:40:00 21.1 2 25.2 16.1 20.9 2.1 25.2 14.9 6 5 13 305 -3.8 0 -3.3 -4 11/09/2005 19:50:00 22.2 2.1 26.3 15.6 21.9 2.1 26 15.6 7 6 13 305 -3.8 0.1 -3.3 -4 11/09/2005 20:00:00 22.6 1.8 27.1 16.1 22.2 1.8 26 17.2 11 5 15 305 -3.8 0 -3.6 -4 11/09/2005 20:10:00 22.1 1.8 26.3 16.8 22.1 1.7 26.3 17.2 10 6 8 305 -3.7 0 -3.6 -4 11/09/2005 20:20:00 21.2 2.1 26 14.9 21.2 2 26 16.4 12 6 7 305 -3.7 0.1 -3.3 -3.8 11/09/2005 20:30:00 21.6 1.9 26.3 15.3 21.6 1.9 26.8 14.9 10 6 9 305 -3.7 0.1 -3.3 -3.8 11/09/2005 20:40:00 21.9 2.4 27.5 14.9 21.7 2.3 26.8 15.3 8 5 13 305 -3.7 0.1 -3.3 -3.8 11/09/2005 20:50:00 22.2 1.8 26.3 16.4 22 1.8 26.3 16.1 10 5 15 305 -3.7 0 -3.3 -3.8 11/09/2005 21:00:00 22.1 2.3 27.1 15.3 21.8 2.3 26.8 14.9 16 4 19 305 -3.7 0 -3.6 -4 11/09/2005 21:10:00 21.8 2 26 17.2 21.7 2 25.6 16.8 15 5 18 305 -3.7 0 -3.3 -4 11/09/2005 21:20:00 21.2 2.3 26.8 15.6 21 2.4 26.3 14.5 14 6 6 305 -3.5 0 -3.3 -3.8 11/09/2005 21:30:00 21.2 1.7 26 17.2 21.2 1.7 26 16.8 9 6 5 305 -3.5 0 -3.3 -3.8 11/09/2005 21:40:00 21.3 2.2 26 15.3 21.1 2.2 26 15.3 12 5 11 305 -3.6 0 -3.3 -3.8 11/09/2005 21:50:00 21.1 2.7 26.3 14.9 20.8 2.7 26.3 13.7 11 6 7 305 -3.5 0 -3.1 -3.8 11/09/2005 22:00:00 21.3 2 25.2 15.6 21 2.1 25.2 16.1 10 5 4 305 -3.4 0 -3.1 -3.6 11/09/2005 22:10:00 21.8 1.7 26 16.4 21.7 1.7 25.6 16.8 13 4 15 305 -3.5 0 -3.3 -3.8 11/09/2005 22:20:00 21.1 1.7 25.2 15.3 21 1.8 25.2 14.9 9 5 14 305 -3.3 0 -3.1 -3.6 11/09/2005 22:30:00 21 1.6 24.8 16.4 21 1.7 24.4 16.1 10 5 12 305 -3.3 0 -3.1 -3.6 11/09/2005 22:40:00 22 1.8 26.8 16.8 21.9 1.9 26.3 16.1 17 4 13 305 -3.4 0 -3.3 -3.6 11/09/2005 22:50:00 22.3 1.7 26.3 17.6 22 1.9 26.8 16.8 14 5 14 305 -3.4 0 -3.3 -3.6 11/09/2005 23:00:00 22.1 1.9 26 16.8 21.8 2.2 26.3 16.1 12 5 9 305 -3.4 0 -3.3 -3.6 11/09/2005 23:10:00 20.6 2 25.2 15.3 20.5 2.1 25.2 15.3 8 5 4 305 -3.3 0 -2.9 -3.6 11/09/2005 23:20:00 21 2 25.2 16.1 20.9 1.9 24.8 16.4 8 5 1 305 -3.2 0 -3.1 -3.3 11/09/2005 23:30:00 20.1 1.7 24.4 14.9 19.9 1.9 24.8 14.5 8 5 8 305 -3.2 0 -3.1 -3.3 11/09/2005 23:40:00 20.6 2.2 26 15.3 20.5 2.4 26.8 14.9 5 4 2 305 -3.3 0 -3.1 -3.3 11/09/2005 23:50:00 21.7 1.5 25.2 16.1 21.7 1.7 25.2 16.8 5 4 5 305 -3.2 0 -2.9 -3.3 11/10/2005 00:00:00 19.3 1.7 24.4 14.9 19.2 1.8 24.8 14.5 8 5 9 305 -3.1 0.1 -2.9 -3.3 11/10/2005 00:10:00 20 1.5 23.3 15.6 20 1.7 23.7 14.1 5 5 5 305 -3 0 -2.7 -3.1 11/10/2005 00:20:00 19.6 1.7 23.7 14.5 19.6 1.8 23.7 14.1 3 5 4 305 -3 0 -2.7 -3.1 11/10/2005 00:30:00 20.3 1.8 24.4 14.9 20.2 1.9 24.8 15.6 4 5 11 305 -2.9 0 -2.7 -3.1 11/10/2005 00:40:00 18.4 1.9 24 14.1 18.3 2 23.7 12.6 5 5 9 305 -2.8 0 -2.7 -3.1 11/10/2005 00:50:00 18.9 1.6 23.7 14.1 18.8 1.7 23.7 13.3 6 6 3 305 -2.8 0 -2.7 -3.1 11/10/2005 01:00:00 19.2 1.7 23.7 14.1 19.1 1.7 22.9 13.7 7 6 19 305 -2.9 0 -2.7 -3.1 11/10/2005 01:10:00 19.2 1.6 22.9 15.3 19.2 1.7 23.7 15.3 4 5 9 305 -2.8 0 -2.7 -3.1 11/10/2005 01:20:00 20.2 1.9 24 15.3 20 1.9 24 16.1 6 4 9 305 -2.9 0 -2.7 -3.1 11/10/2005 01:30:00 19.9 1.5 22.9 15.6 19.7 1.5 22.9 16.1 3 5 3 305 -2.9 0 -2.7 -3.1 11/10/2005 01:40:00 18.6 1.5 22.1 14.5 18.6 1.5 22.6 14.1 359 5 6 305 -3 0 -2.7 -3.1 11/10/2005 01:50:00 18.4 1.5 22.6 14.1 18.4 1.5 22.9 14.5 359 5 357 305 -3.2 0.1 -2.7 -3.3 11/10/2005 02:00:00 18.1 1.9 22.9 13 18.2 2 23.7 13 1 4 1 305 -3.1 0.1 -2.7 -3.3 11/10/2005 02:10:00 17.4 1.7 21.4 13.7 17.4 1.7 21.8 13 4 5 1 305 -3.1 0 -2.7 -3.3 11/10/2005 02:20:00 17.5 1.9 21.4 13 17.4 2 21.8 12.2 3 5 7 305 -3.1 0.1 -2.7 -3.3 11/10/2005 02:30:00 18.3 1.5 22.1 14.1 18.3 1.6 22.6 13.7 359 4 357 305 -3.3 0 -3.1 -3.6 11/10/2005 02:40:00 18.2 1.6 21.4 13.3 18.1 1.7 21.4 13.7 4 6 13 305 -3.3 0 -3.1 -3.3 11/10/2005 02:50:00 18.6 1.8 22.1 13.3 18.6 1.7 22.6 13.3 0 5 358 305 -3.2 0.1 -2.9 -3.3 11/10/2005 03:00:00 18.4 1.5 21.4 13.7 18.3 1.4 22.6 14.1 1 5 4 305 -3.3 0 -3.1 -3.6 11/10/2005 03:10:00 18.9 1.6 23.7 14.5 18.8 1.7 23.7 14.9 3 4 11 305 -3.3 0.1 -3.1 -3.6 11/10/2005 03:20:00 17.9 1.7 21.8 13.7 17.9 1.7 21.8 13.3 358 5 353 305 -3.1 0.1 -2.7 -3.3 11/10/2005 03:30:00 18.4 1.7 21.8 13.7 18.3 1.7 22.1 13.3 358 4 1 305 -3.3 0 -3.1 -3.3 11/10/2005 03:40:00 17.9 1.6 21.4 13 17.9 1.7 21.4 12.6 3 4 2 305 -3.2 0 -3.1 -3.3 11/10/2005 03:50:00 18.7 1.3 21.4 14.5 18.6 1.3 21.4 14.9 7 4 7 305 -3.5 0 -3.1 -3.8 11/10/2005 04:00:00 17.8 1.6 21.8 13 17.8 1.7 22.1 12.6 356 8 351 305 -3.3 0.1 -2.9 -3.8 11/10/2005 04:10:00 17.9 1.2 21 13.7 18 1.2 20.6 14.9 354 5 352 305 -3.3 0 -3.1 -3.6 11/10/2005 04:20:00 17.6 1.9 21.4 13 17.7 1.9 21.4 12.2 3 6 347 305 -3.3 0 -3.1 -3.6 11/10/2005 04:30:00 17.8 1.5 21.4 13.3 17.9 1.6 21.4 13.3 356 5 358 305 -3.5 0.1 -3.3 -3.8 11/10/2005 04:40:00 17.4 1.7 21.4 13 17.7 1.7 22.1 11.8 353 4 351 305 -3.5 0 -3.3 -3.6 11/10/2005 04:50:00 16.5 1.5 20.2 12.2 16.4 1.5 20.2 12.2 359 8 350 305 -3.2 0.1 -2.9 -3.3 11/10/2005 05:00:00 17.6 2 22.9 12.6 17.5 2.1 22.9 13 1 5 1 305 -3.7 0.3 -3.1 -4.2 11/10/2005 05:10:00 17.2 1.8 20.2 11.8 17.4 2.1 21.4 11.8 353 5 354 305 -3.8 0.1 -3.3 -4 11/10/2005 05:20:00 18.4 1.4 21.4 13.7 18.5 1.5 21.8 14.1 354 4 356 305 -4 0 -3.8 -4.2 11/10/2005 05:30:00 17.6 1.5 21 13.7 17.9 1.6 21 13.7 352 5 353 305 -4 0 -3.8 -4.2 11/10/2005 05:40:00 17.6 1.3 21 13.7 17.7 1.4 20.6 14.1 355 4 3 305 -3.9 0 -3.8 -4 11/10/2005 05:50:00 15.8 1.6 19.1 11.8 16 1.7 19.5 11.5 353 5 359 305 -3.9 0 -3.8 -4 11/10/2005 06:00:00 17.4 1.7 21.4 12.6 17.4 1.8 21.4 11.8 351 4 357 305 -3.9 0 -3.8 -4 11/10/2005 06:10:00 17.3 1.8 21.4 11.8 17.6 1.8 21.8 11.8 355 5 356 305 -4 0 -3.6 -4.2 11/10/2005 06:20:00 18.1 1.5 21.8 14.1 18.3 1.6 21.8 14.5 351 3 352 305 -3.9 0 -3.8 -4 11/10/2005 06:30:00 17.6 1.7 21.4 13 17.9 1.7 21.4 13.7 353 5 355 305 -4 0 -3.8 -4.2 11/10/2005 06:40:00 17.5 1.4 20.6 13.3 17.6 1.5 21.4 13.3 354 6 358 305 -3.9 0 -3.8 -4 11/10/2005 06:50:00 17 1.2 19.9 13.7 17.1 1.3 20.2 13.7 357 3 0 305 -4.1 0 -3.8 -4.5 11/10/2005 07:00:00 18.1 1.9 22.1 13 18.2 1.9 22.9 14.1 351 6 355 305 -3.8 0 -3.6 -4 11/10/2005 07:10:00 17.4 1.4 21.4 13.7 17.5 1.5 21.4 14.1 356 6 0 305 -3.9 0 -3.8 -4 11/10/2005 07:20:00 16.7 1.4 20.2 12.6 16.6 1.5 19.9 11.8 5 5 4 305 -3.9 0.3 -3.3 -4.2 11/10/2005 07:30:00 17.6 1.9 21.8 12.6 17.8 2 22.1 12.2 358 6 351 305 -3.5 0.1 -3.1 -3.8 11/10/2005 07:40:00 15.6 1.5 19.9 11.5 15.7 1.5 20.2 11.1 1 8 359 305 -3.7 0.1 -3.3 -4 11/10/2005 07:50:00 16.3 1.5 20.2 12.2 16.4 1.7 20.6 11.5 354 5 352 305 -3.7 0 -3.3 -4 11/10/2005 08:00:00 16 1.9 20.6 11.1 16 1.9 20.6 11.1 1 5 3 305 -3.3 0 -3.1 -3.8 11/10/2005 08:10:00 17.8 1.5 20.6 13 17.7 1.5 20.6 13 9 5 5 305 -3.2 0 -3.1 -3.3 11/10/2005 08:20:00 17.4 1.6 20.6 12.2 17.3 1.7 21 12.2 10 4 11 305 -3.2 0 -2.9 -3.3 11/10/2005 08:30:00 17 1.7 20.6 13 17 1.7 20.6 12.2 13 4 14 305 -3.4 0.2 -2.9 -3.8 11/10/2005 08:40:00 16.7 1.5 20.6 12.2 16.7 1.5 21 11.8 7 6 6 305 -3.3 0.2 -2.9 -3.8 11/10/2005 08:50:00 16.6 1.7 20.2 13 16.8 1.7 20.6 12.6 6 6 16 305 -3.2 0.1 -2.9 -3.6 11/10/2005 09:00:00 16.8 1.5 19.9 12.6 16.8 1.6 20.2 11.1 3 4 4 305 -3.3 0.1 -3.1 -3.6 11/10/2005 09:10:00 17.4 1.5 20.6 13 17.3 1.5 21 13 11 4 18 305 -3.1 0.1 -2.9 -3.3 11/10/2005 09:20:00 17.1 1.5 19.9 12.2 17 1.5 20.2 12.2 8 4 12 305 -3.2 0 -3.1 -3.3 11/10/2005 09:30:00 17.1 1.5 20.2 13 17.2 1.6 20.6 12.2 5 4 2 305 -3.1 0.1 -2.9 -3.3 11/10/2005 09:40:00 16.4 1.4 19.5 11.8 16.5 1.5 19.9 12.2 2 5 3 305 -3 0 -2.7 -3.3 11/10/2005 09:50:00 15.7 1.5 19.5 11.8 15.7 1.6 19.5 11.5 5 4 0 305 -3.3 0.1 -3.1 -3.6 11/10/2005 10:00:00 15.6 1.4 18.3 11.8 15.7 1.6 19.1 11.5 0 6 355 305 -3.1 0 -2.9 -3.3 11/10/2005 10:10:00 15.7 1.3 19.1 11.5 15.9 1.5 19.5 12.2 5 6 357 305 -3.1 0 -2.9 -3.3 11/10/2005 10:20:00 16.1 1.7 20.2 12.2 16.2 1.8 19.9 11.5 7 4 11 305 -3.1 0 -2.7 -3.3 11/10/2005 10:30:00 15.1 1.6 19.9 11.5 15.2 1.6 19.9 11.5 6 5 12 305 -3 0 -2.7 -3.1 11/10/2005 10:40:00 16.9 1.7 20.6 12.6 16.9 1.7 21 13 12 7 11 305 -3.5 0.3 -2.9 -4 11/10/2005 10:50:00 15.8 1.3 18.7 13 15.7 1.4 19.1 12.2 15 5 15 305 -3.9 0.1 -3.6 -4.2 11/10/2005 11:00:00 14.7 1.3 18.3 11.5 14.7 1.3 18.7 11.5 12 6 9 305 -3.8 0 -3.6 -4 11/10/2005 11:10:00 16 1.5 20.6 12.2 16.1 1.6 20.6 11.8 10 5 15 305 -3.5 0 -3.1 -3.8 11/10/2005 11:20:00 15.4 1.3 17.9 11.1 15.4 1.4 17.9 10.3 10 6 8 305 -3.3 0 -3.1 -3.6 11/10/2005 11:30:00 15.8 1.6 18.7 11.5 15.9 1.7 19.1 11.5 11 5 7 305 -3.2 0.1 -3.1 -3.6 11/10/2005 11:40:00 16.3 1.7 21.4 11.8 16.1 1.7 21.4 12.2 15 9 13 305 -3.3 0.2 -2.9 -3.8 11/10/2005 11:50:00 14.7 1.1 18.7 11.1 14.8 1.1 18.3 11.8 16 5 14 305 -3.5 0.2 -3.1 -3.8 11/10/2005 12:00:00 15.9 1.5 19.1 11.8 16 1.5 19.5 12.2 11 5 8 305 -3.1 0 -2.7 -3.3 11/10/2005 12:10:00 15.3 1.5 18.7 12.2 15.2 1.5 19.1 12.2 8 6 2 305 -2.8 0 -2.7 -3.1 11/10/2005 12:20:00 15.2 1.2 18.7 12.2 15.4 1.3 18.7 11.1 359 4 355 305 -3 0.1 -2.7 -3.3 11/10/2005 12:30:00 15.5 1.3 19.5 12.2 15.5 1.5 19.9 11.5 358 4 356 305 -3.1 0 -2.9 -3.3 11/10/2005 12:40:00 15.6 1.4 19.1 12.2 15.6 1.5 19.1 11.5 354 5 358 305 -3.1 0.1 -2.9 -3.3 11/10/2005 12:50:00 15.3 1.3 18.3 11.5 15.5 1.4 18.7 11.5 355 4 355 305 -3.2 0.1 -2.9 -3.3 11/10/2005 13:00:00 15 1.2 17.6 11.5 15.2 1.3 18.3 11.8 353 4 350 305 -3.1 0 -2.9 -3.3 11/10/2005 13:10:00 14.8 1.3 18.3 11.5 15.1 1.3 19.5 11.8 357 3 352 305 -3.1 0 -2.9 -3.3 11/10/2005 13:20:00 14.8 1.3 17.9 11.1 15 1.3 18.7 11.5 358 4 357 305 -3.2 0 -2.9 -3.3 11/10/2005 13:30:00 13.9 1.1 16.8 10.3 14 1.1 16.4 9.9 354 5 0 305 -3.2 0 -2.9 -3.3 11/10/2005 13:40:00 14.2 1.3 16.8 10.7 14.4 1.3 17.2 10.7 354 5 355 305 -3.1 0 -2.9 -3.3 11/10/2005 13:50:00 14 1.2 16.8 11.1 14.1 1.2 16.8 10.3 354 4 357 305 -3.2 0 -3.1 -3.3 11/10/2005 14:00:00 14.2 1.1 16.4 11.5 14.3 1.2 17.2 11.5 359 5 354 305 -3.1 0 -2.7 -3.3 11/10/2005 14:10:00 14 1 16.8 11.1 14.1 1.1 17.2 11.1 359 6 352 305 -3.2 0 -2.9 -3.3 11/10/2005 14:20:00 13.7 1.1 16.4 10.7 14 1.2 16.8 11.1 354 5 351 305 -3.1 0 -3.1 -3.3 11/10/2005 14:30:00 15.1 1 17.9 12.6 15.3 1.1 18.3 12.2 356 4 354 305 -3.1 0 -2.9 -3.3 11/10/2005 14:40:00 15.3 1.2 18.7 11.8 15.5 1.3 18.7 11.8 3 4 4 305 -3 0 -2.7 -3.1 11/10/2005 14:50:00 14.9 1.2 18.3 11.5 15.1 1.3 18.3 11.5 353 5 350 305 -3 0 -2.7 -3.1 11/10/2005 15:00:00 16.4 1.1 19.1 13.7 16.5 1.2 19.5 13.7 354 4 358 305 -3.1 0 -3.1 -3.3 11/10/2005 15:10:00 15.4 1.1 17.9 12.2 15.6 1.2 18.7 11.8 354 6 346 305 -3.2 0.1 -2.9 -3.3 11/10/2005 15:20:00 14.8 0.9 16.8 12.2 15 1 17.6 12.2 354 5 348 305 -3.2 0 -3.1 -3.3 11/10/2005 15:30:00 15.6 1.2 18.3 11.8 15.7 1.3 18.7 11.8 354 4 355 305 -3.1 0 -3.1 -3.3 11/10/2005 15:40:00 14.8 1.1 17.9 12.2 14.9 1.1 18.3 12.2 355 4 356 305 -3 0 -2.7 -3.1 11/10/2005 15:50:00 14.4 1.2 17.9 11.5 14.6 1.2 18.3 11.8 355 4 358 305 -3 0 -2.7 -3.1 11/10/2005 16:00:00 15.3 1 17.6 12.2 15.5 1.1 17.9 11.5 358 4 355 305 -3.1 0 -2.9 -3.3 11/10/2005 16:10:00 14.8 1.3 17.9 11.5 15 1.3 17.9 11.1 358 5 359 305 -3.3 0 -3.1 -3.3 11/10/2005 16:20:00 13.7 1.1 16.4 10.7 13.9 1.2 16.4 9.5 1 5 3 305 -3.2 0.1 -2.7 -3.3 11/10/2005 16:30:00 13.8 1.1 16.8 11.1 14 1.1 17.6 10.7 356 5 354 305 -3.3 0 -3.1 -3.3 11/10/2005 16:40:00 13.4 1.1 15.3 10.3 13.5 1.1 16.1 10.3 350 4 357 305 -3.2 0 -3.1 -3.3 11/10/2005 16:50:00 14.6 1.5 18.7 10.7 14.8 1.6 18.3 10.7 354 5 2 305 -3.2 0 -3.1 -3.3 11/10/2005 17:00:00 16.4 0.8 19.5 13.7 16.5 1 19.5 13.7 357 4 353 305 -3.2 0 -3.1 -3.3 11/10/2005 17:10:00 15.2 1.3 17.6 11.5 15.3 1.5 17.9 11.5 353 4 352 305 -3.3 0 -3.1 -3.3 11/10/2005 17:20:00 15.2 1.2 17.9 11.8 15.5 1.3 18.3 11.8 353 4 350 305 -3.3 0 -3.1 -3.6 11/10/2005 17:30:00 14.9 1.3 18.3 11.8 15 1.3 18.7 11.8 350 5 351 305 -3.4 0 -3.3 -3.6 11/10/2005 17:40:00 14.7 1.3 17.6 11.5 14.8 1.3 17.9 11.5 351 5 350 305 -3.4 0 -3.3 -3.6 11/10/2005 17:50:00 14.9 1.4 17.9 11.5 15 1.5 17.9 11.5 352 5 353 305 -3.4 0 -3.3 -3.6 11/10/2005 18:00:00 15.9 1.2 18.7 12.2 16.2 1.2 19.1 12.6 347 5 343 305 -3.5 0 -3.3 -3.8 11/10/2005 18:10:00 16.5 1.2 19.5 13.3 16.6 1.3 19.5 13.3 349 5 346 305 -3.6 0 -3.3 -3.8 11/10/2005 18:20:00 15.4 1.3 18.3 12.2 15.6 1.4 18.7 12.2 357 5 0 305 -3.5 0 -3.3 -3.8 11/10/2005 18:30:00 14.6 1.2 17.2 11.5 14.8 1.2 17.9 11.8 353 5 350 305 -3.5 0 -3.3 -3.8 11/10/2005 18:40:00 15.3 0.8 17.2 11.8 15.4 0.9 17.2 11.8 353 3 352 305 -3.6 0 -3.3 -3.8 11/10/2005 18:50:00 15.3 1.3 17.9 12.2 15.4 1.4 18.3 11.1 355 5 357 305 -3.5 0 -3.3 -3.8 11/10/2005 19:00:00 15.2 1.3 17.6 11.5 15.4 1.5 18.3 11.5 355 4 350 305 -3.5 0 -3.3 -3.8 11/10/2005 19:10:00 16.1 0.9 17.9 13.3 16.3 1 18.7 13.3 351 3 353 305 -3.8 0 -3.6 -3.8 11/10/2005 19:20:00 16.3 1 19.5 13.3 16.5 1.1 19.5 13 353 4 353 305 -3.7 0 -3.3 -3.8 11/10/2005 19:30:00 17.3 1 19.5 13.7 17.5 1.2 19.9 13.3 350 3 350 305 -3.7 0 -3.6 -3.8 11/10/2005 19:40:00 18.2 1.1 21 14.1 18.4 1.1 21 15.3 352 4 354 305 -3.8 0 -3.6 -4 11/10/2005 19:50:00 17 1.2 19.9 14.1 17.1 1.3 19.9 13.7 353 5 350 305 -3.9 0 -3.8 -4 11/10/2005 20:00:00 16.2 1.2 18.7 12.6 16.4 1.3 19.1 12.2 354 4 348 305 -3.9 0 -3.8 -4 11/10/2005 20:10:00 15.8 1.1 17.9 13 15.9 1.2 18.7 12.6 353 5 353 305 -3.8 0 -3.6 -4 11/10/2005 20:20:00 16.5 1.3 19.1 12.2 16.7 1.5 19.5 11.8 353 5 352 305 -3.9 0 -3.6 -4 11/10/2005 20:30:00 15.9 1.1 17.9 12.2 16 1.2 18.3 12.2 351 4 349 305 -3.9 0 -3.6 -4 11/10/2005 20:40:00 16.4 1.1 18.3 12.2 16.6 1.2 18.7 12.6 349 5 340 305 -3.9 0 -3.8 -4 11/10/2005 20:50:00 16.4 1 19.1 13 16.7 1.1 19.5 13.3 352 4 347 305 -4 0 -3.8 -4.2 11/10/2005 21:00:00 15.5 1 17.6 12.6 15.6 1.1 17.9 11.8 352 5 357 305 -4 0 -3.8 -4 11/10/2005 21:10:00 15.5 1.2 17.9 11.8 15.6 1.3 18.3 11.8 355 4 351 305 -3.9 0 -3.8 -4 11/10/2005 21:20:00 15.6 1.2 17.9 13 15.8 1.3 18.3 12.2 351 4 352 305 -3.9 0 -3.8 -4 11/10/2005 21:30:00 16.1 1 18.3 13 16.2 1.1 18.7 13.3 350 3 350 305 -4 0 -3.8 -4.2 11/10/2005 21:40:00 15.6 1 17.6 12.6 15.8 1 17.9 13 357 4 354 305 -4 0 -3.8 -4 11/10/2005 21:50:00 15 1.3 17.9 11.8 15.3 1.3 18.3 11.8 350 5 343 305 -4 0 -3.8 -4.2 11/10/2005 22:00:00 16.8 1 18.7 13.7 17 1.2 19.5 13.7 352 3 352 305 -4 0 -3.8 -4.2 11/10/2005 22:10:00 17.2 1.1 19.9 13.7 17.3 1.2 20.2 13.3 356 5 356 305 -4 0 -3.8 -4.2 11/10/2005 22:20:00 14.9 1.5 18.3 11.1 15.2 1.5 18.7 11.8 355 4 352 305 -4 0 -3.8 -4.2 11/10/2005 22:30:00 14.5 1.5 16.8 10.7 14.6 1.5 17.6 10.3 349 4 349 305 -4.1 0 -3.8 -4.2 11/10/2005 22:40:00 14.3 1.4 17.2 10.7 14.4 1.5 17.6 10.3 347 5 347 305 -4.1 0 -3.8 -4.2 11/10/2005 22:50:00 15.4 1.1 18.3 12.6 15.7 1 17.9 12.6 346 4 344 305 -4.2 0 -4 -4.5 11/10/2005 23:00:00 15.2 1.1 17.6 11.8 15.4 1.3 17.9 11.5 351 4 351 305 -4.1 0 -3.8 -4.2 11/10/2005 23:10:00 15.1 1.2 17.6 11.5 15.3 1.3 18.3 11.1 349 4 347 305 -4.1 0 -3.8 -4.2 11/10/2005 23:20:00 15.9 1.1 18.7 11.8 16 1.3 19.1 12.2 352 4 350 305 -4.1 0 -3.8 -4.5 11/10/2005 23:30:00 15.2 0.9 17.2 12.2 15.4 1 17.6 12.2 355 4 345 305 -4.2 0 -4 -4.5 11/10/2005 23:40:00 14.8 0.9 16.8 11.8 15.1 1 17.6 12.2 351 4 350 305 -4.2 0 -4 -4.5 11/10/2005 23:50:00 14.4 1.2 17.6 10.7 14.6 1.3 17.9 9.9 351 4 348 305 -4.2 0 -4 -4.5 11/11/2005 00:00:00 15.3 1 17.6 12.6 15.4 1.1 17.6 12.2 355 5 356 305 -4.1 0 -3.8 -4.2 11/11/2005 00:10:00 15.6 1.4 18.3 11.8 15.8 1.5 18.7 11.8 357 4 352 305 -4.1 0.1 -3.8 -4.5 11/11/2005 00:20:00 15.7 1.2 18.3 12.2 15.8 1.3 19.1 11.8 357 4 354 305 -4.2 0 -3.8 -4.5 11/11/2005 00:30:00 15 1.3 17.6 11.8 15.2 1.4 18.3 11.5 356 4 356 305 -4.2 0 -4 -4.5 11/11/2005 00:40:00 13.7 1.1 16.1 10.3 14.1 1.2 16.4 10.7 356 5 0 305 -4.1 0 -3.8 -4.5 11/11/2005 00:50:00 14 1 16.1 10.7 14.3 1.1 16.4 11.5 355 4 354 305 -4.1 0 -3.8 -4.5 11/11/2005 01:00:00 14.2 1.1 17.6 11.1 14.4 1.1 17.6 11.8 356 4 355 305 -4.1 0 -3.8 -4.5 11/11/2005 01:10:00 14.9 1 16.8 11.8 15.1 1.1 17.2 11.8 358 4 0 305 -4.2 0 -3.8 -4.2 11/11/2005 01:20:00 14.8 1 16.8 10.7 14.9 1 16.8 11.8 356 4 354 305 -4.1 0 -3.8 -4.2 11/11/2005 01:30:00 15 1 17.6 11.8 15.2 1.1 17.9 11.8 356 4 352 305 -4.1 0 -3.8 -4.2 11/11/2005 01:40:00 14.9 0.8 16.4 12.2 15.2 0.9 17.9 12.6 358 4 353 305 -4.1 0 -3.8 -4.5 11/11/2005 01:50:00 14.5 1 16.4 11.5 14.7 1 17.2 11.5 357 3 357 305 -4.1 0 -4 -4.2 11/11/2005 02:00:00 14.2 1 16.4 10.7 14.4 1 16.8 11.1 355 3 352 305 -4.1 0 -3.8 -4.2 11/11/2005 02:10:00 13.6 0.8 15.3 11.1 13.8 1 15.6 10.7 357 4 359 305 -4 0 -3.8 -4.2 11/11/2005 02:20:00 13.9 0.9 15.6 11.8 14.1 1 16.4 11.8 358 4 355 305 -4 0 -3.8 -4.2 11/11/2005 02:30:00 14.3 0.8 16.1 11.1 14.5 0.9 16.4 11.1 355 4 350 305 -4 0 -3.8 -4.2 11/11/2005 02:40:00 14.3 0.7 15.6 12.2 14.5 0.8 16.4 11.8 352 4 354 305 -4 0 -3.8 -4.2 11/11/2005 02:50:00 13.6 0.9 15.3 11.1 13.7 0.9 15.6 11.1 354 4 353 305 -4 0 -3.8 -4 11/11/2005 03:00:00 13 1.1 14.9 9.9 13.3 1.1 15.6 9.5 352 4 357 305 -4 0 -3.8 -4 11/11/2005 03:10:00 12.8 0.8 14.9 10.7 13.1 0.9 15.6 10.7 353 4 348 305 -4 0 -3.8 -4 11/11/2005 03:20:00 12.7 0.9 15.3 9.9 12.9 1 15.3 10.7 350 4 346 305 -4.1 0 -3.8 -4.2 11/11/2005 03:30:00 12.8 1 14.9 9.5 13.1 1 14.9 10.7 349 4 354 305 -4.1 0 -3.8 -4.2 11/11/2005 03:40:00 12.5 0.8 14.5 10.3 12.7 0.9 14.9 9.5 352 5 356 305 -4 0 -3.8 -4.2 11/11/2005 03:50:00 12 0.7 13.3 9.5 12.3 0.8 14.1 9.1 350 4 352 305 -3.9 0 -3.8 -4 11/11/2005 04:00:00 12.2 0.7 14.1 9.5 12.5 0.8 14.5 9.9 351 3 348 305 -3.9 0 -3.8 -4 11/11/2005 04:10:00 12.1 0.8 13.7 9.5 12.4 0.9 14.5 9.5 348 4 344 305 -3.9 0 -3.6 -4 11/11/2005 04:20:00 13 0.7 14.9 10.7 13.3 0.8 15.3 11.5 352 4 349 305 -3.9 0 -3.6 -4 11/11/2005 04:30:00 12 0.9 14.1 9.5 12.3 1 14.5 9.9 354 4 356 305 -3.8 0 -3.6 -3.8 11/11/2005 04:40:00 11.5 0.7 13.3 9.1 11.9 0.7 14.1 9.5 352 5 356 305 -3.8 0 -3.6 -4 11/11/2005 04:50:00 11.6 1 13.7 9.1 11.9 1 14.9 9.1 350 5 347 305 -3.8 0 -3.6 -4 11/11/2005 05:00:00 11.9 0.7 13.7 9.9 12.2 0.8 14.1 9.5 352 4 348 305 -3.9 0 -3.8 -3.8 11/11/2005 05:10:00 11.9 0.7 14.1 9.5 12.2 0.8 14.1 9.9 355 4 356 305 -3.8 0 -3.6 -3.8 11/11/2005 05:20:00 12 0.8 14.1 9.5 12.3 0.9 14.5 9.5 354 5 349 305 -3.8 0 -3.6 -4 11/11/2005 05:30:00 11.8 0.8 13.7 9.1 12.1 0.9 13.7 8.8 355 4 352 305 -3.9 0 -3.8 -4 11/11/2005 05:40:00 11 0.8 13.3 8.4 11.3 0.9 13.7 8.8 354 5 349 305 -3.9 0 -3.8 -4 11/11/2005 05:50:00 10.5 0.8 12.2 8.4 10.9 0.8 13 8.8 353 6 353 305 -3.9 0 -3.6 -4 11/11/2005 06:00:00 10.4 0.6 11.8 8.4 10.7 0.6 12.6 8.8 355 4 350 305 -3.7 0 -3.6 -3.8 11/11/2005 06:10:00 11.5 0.6 13 8.8 11.9 0.7 13.3 9.5 352 5 352 305 -3.7 0 -3.6 -3.8 11/11/2005 06:20:00 11.5 0.7 13.3 9.1 11.8 0.8 13.7 9.1 359 6 0 305 -3.7 0 -3.3 -3.8 11/11/2005 06:30:00 11.3 0.8 13.3 8.4 11.5 1 13.7 8.8 0 3 0 305 -3.6 0 -3.3 -3.8 11/11/2005 06:40:00 10.8 0.7 12.2 8.8 11.1 0.8 12.6 8.8 354 5 354 305 -3.6 0 -3.3 -3.8 11/11/2005 06:50:00 10.5 0.7 12.6 8 10.8 0.8 13 8 358 5 352 305 -3.7 0 -3.3 -3.8 11/11/2005 07:00:00 11.3 0.7 13 9.5 11.6 0.8 13.3 9.1 356 4 352 305 -3.7 0 -3.6 -3.8 11/11/2005 07:10:00 12.3 0.9 14.1 9.5 12.6 0.9 14.5 9.9 357 4 358 305 -3.8 0 -3.6 -3.8 11/11/2005 07:20:00 12.7 0.8 14.5 10.3 13 0.9 14.9 9.5 358 4 358 305 -3.8 0 -3.6 -4 11/11/2005 07:30:00 11.9 1 14.1 8.4 12.1 1.1 14.1 8.4 358 5 1 305 -3.8 0 -3.6 -4 11/11/2005 07:40:00 11.4 0.8 13.3 9.1 11.6 1 14.1 8.4 357 4 353 305 -3.9 0 -3.6 -4 11/11/2005 07:50:00 11.2 0.8 13 9.1 11.5 0.9 13.7 9.5 354 4 355 305 -3.9 0 -3.6 -4 11/11/2005 08:00:00 11 0.6 12.6 8.8 11.4 0.6 13 9.9 356 3 358 305 -3.9 0 -3.8 -4 11/11/2005 08:10:00 11.1 0.7 12.6 9.1 11.4 0.8 13.3 9.1 356 3 358 305 -4 0 -3.8 -4.2 11/11/2005 08:20:00 11.2 0.7 13.3 8.8 11.5 0.8 13.3 9.1 355 3 350 305 -3.9 0 -3.8 -4 11/11/2005 08:30:00 11.7 0.8 13.3 9.1 12.1 0.8 13.7 9.9 354 4 350 305 -3.9 0 -3.6 -4 11/11/2005 08:40:00 12.4 0.8 14.1 9.9 12.7 0.8 14.9 9.5 357 4 357 305 -3.9 0 -3.8 -4 11/11/2005 08:50:00 12.1 0.9 14.5 9.5 12.4 0.9 14.9 10.3 359 4 0 305 -3.8 0 -3.6 -4 11/11/2005 09:00:00 12.2 0.8 14.1 9.9 12.4 0.9 14.5 10.3 353 3 351 305 -3.9 0 -3.8 -4 11/11/2005 09:10:00 11.4 0.7 13 8.8 11.7 0.8 13.3 8.8 351 4 354 305 -3.9 0 -3.8 -4 11/11/2005 09:20:00 11.4 0.8 13.7 9.5 11.6 1 14.1 9.1 348 4 345 305 -3.9 0 -3.8 -4 11/11/2005 09:30:00 11.1 0.8 12.6 8.8 11.5 0.9 13.3 8.8 352 5 348 305 -3.9 0 -3.8 -4 11/11/2005 09:40:00 11.4 0.8 13 9.1 11.8 0.9 13.3 9.5 351 3 353 305 -3.9 0 -3.6 -4 11/11/2005 09:50:00 11.1 0.8 13 9.1 11.5 0.8 13.3 9.5 354 4 353 305 -3.8 0 -3.6 -3.8 11/11/2005 10:00:00 11.7 0.9 14.1 9.1 12.1 1 14.1 9.1 355 4 354 305 -3.7 0 -3.3 -3.8 11/11/2005 10:10:00 12.1 0.7 13.7 9.5 12.4 0.8 14.1 9.9 354 4 354 305 -3.7 0 -3.6 -3.8 11/11/2005 10:20:00 12.6 0.8 14.5 10.3 12.9 0.9 15.3 10.7 356 3 351 305 -3.6 0 -3.3 -3.8 11/11/2005 10:30:00 12 0.9 14.5 9.1 12.3 1 14.5 9.5 356 4 353 305 -3.6 0 -3.3 -3.8 11/11/2005 10:40:00 11.7 0.8 13.7 9.5 12 0.9 14.1 9.1 357 5 0 305 -3.5 0 -3.3 -3.8 11/11/2005 10:50:00 11.7 0.9 13.3 9.1 12 1 13.7 8.8 352 4 354 305 -3.6 0 -3.3 -3.8 11/11/2005 11:00:00 11.6 0.8 13.7 8.8 12 0.8 13.7 9.9 351 4 352 305 -3.6 0 -3.3 -3.8 11/11/2005 11:10:00 11.9 0.9 13.7 9.1 12.2 1.1 14.9 9.1 350 5 348 305 -3.6 0 -3.3 -3.8 11/11/2005 11:20:00 11.7 0.9 13.7 9.1 12 1 14.5 9.5 351 4 350 305 -3.6 0 -3.3 -3.8 11/11/2005 11:30:00 11.9 0.8 14.1 9.1 12.2 1 14.5 9.5 351 5 351 305 -3.5 0 -3.1 -3.8 11/11/2005 11:40:00 11.7 1 14.1 9.1 12.1 1 14.5 9.1 353 5 350 305 -3.3 0 -3.1 -3.6 11/11/2005 11:50:00 12.6 0.8 14.9 10.3 12.9 0.9 14.9 10.7 354 5 349 305 -3.3 0 -3.1 -3.3 11/11/2005 12:00:00 12.7 0.9 14.5 9.9 13.1 1 15.3 10.3 357 4 355 305 -3.3 0 -3.1 -3.3 11/11/2005 12:10:00 12.4 1 14.9 9.9 12.7 1 14.9 9.9 0 4 4 305 -3.2 0 -3.1 -3.3 11/11/2005 12:20:00 11.5 1 13.7 8.8 11.8 1 14.1 8.8 355 4 352 305 -3.1 0.1 -2.7 -3.3 11/11/2005 12:30:00 11.3 1.1 13.7 8 11.5 1.2 14.1 8.8 357 5 355 305 -3.1 0 -2.7 -3.3 11/11/2005 12:40:00 10.8 0.8 12.6 8.4 11.1 0.9 13.3 8.8 357 6 351 305 -3 0 -2.7 -3.1 11/11/2005 12:50:00 10.6 0.8 12.6 8.4 10.8 0.8 13 8.4 355 5 4 305 -2.8 0 -2.7 -3.1 11/11/2005 13:00:00 10.5 0.7 12.2 8.8 10.9 0.8 13 8.8 357 5 357 305 -2.9 0 -2.7 -3.1 11/11/2005 13:10:00 11.5 0.7 13.3 9.5 11.9 0.8 13.7 9.5 0 4 0 305 -3.1 0 -2.7 -3.3 11/11/2005 13:20:00 12.6 0.7 14.5 10.7 13 0.7 15.3 11.1 2 3 2 305 -2.8 0 -2.7 -3.1 11/11/2005 13:30:00 12.3 0.7 13.7 9.9 12.5 0.9 14.5 9.9 4 5 2 305 -2.8 0 -2.7 -3.1 11/11/2005 13:40:00 11.4 1.2 13.7 7.6 11.7 1.3 13.7 8 4 3 4 305 -2.8 0 -2.7 -3.1 11/11/2005 13:50:00 10.1 1.1 11.8 6.8 10.3 1.1 12.6 6.8 1 4 359 305 -2.7 0 -2.4 -2.7 11/11/2005 14:00:00 10 1 12.2 7.2 10.3 1 12.6 8 2 5 5 305 -2.6 0 -2.4 -2.7 11/11/2005 14:10:00 10.6 0.6 11.8 8.8 10.9 0.7 12.6 8.8 359 5 353 305 -2.7 0 -2.4 -2.9 11/11/2005 14:20:00 11.3 0.8 13.3 9.1 11.6 0.8 13.3 9.1 2 4 5 305 -2.7 0 -2.4 -2.7 11/11/2005 14:30:00 11.2 0.8 13 8.8 11.6 0.8 13.7 9.1 353 4 356 305 -2.7 0 -2.4 -3.1 11/11/2005 14:40:00 10.8 0.7 12.6 8.8 11.1 0.8 13.3 9.1 353 5 353 305 -2.8 0 -2.7 -3.1 11/11/2005 14:50:00 11.2 0.6 12.6 9.5 11.6 0.7 13 9.5 351 4 351 305 -3 0 -2.4 -3.1 11/11/2005 15:00:00 11 0.8 12.6 8.8 11.4 0.9 13.3 8.8 348 5 347 305 -2.8 0 -2.7 -3.1 11/11/2005 15:10:00 11.4 0.6 12.6 9.9 11.7 0.7 13.3 9.9 348 4 351 305 -2.9 0 -2.7 -3.1 11/11/2005 15:20:00 10.7 0.9 12.2 8.4 11.1 0.9 12.6 8.8 351 4 345 305 -2.9 0 -2.7 -3.1 11/11/2005 15:30:00 11.1 0.9 13.3 8.8 11.3 1 13.7 8.8 350 5 351 305 -3 0 -2.4 -3.1 11/11/2005 15:40:00 12.2 0.8 13.7 9.5 12.5 0.9 14.5 10.3 350 3 347 305 -3 0 -2.7 -3.3 11/11/2005 15:50:00 12.2 0.8 14.1 10.3 12.6 0.8 14.9 10.3 354 4 348 305 -3.1 0.1 -2.7 -3.3 11/11/2005 16:00:00 12.4 0.8 14.5 10.3 12.7 0.8 14.5 10.3 353 4 342 305 -3.1 0 -3.1 -3.3 11/11/2005 16:10:00 12.3 1 14.5 9.5 12.5 1 14.9 9.5 1 4 1 305 -3.1 0.1 -2.9 -3.3 11/11/2005 16:20:00 11.7 0.8 13.3 9.1 12 1 14.5 8.8 3 4 7 305 -3.2 0 -3.1 -3.3 11/11/2005 16:30:00 10.2 0.8 12.2 8 10.6 0.8 12.6 8.4 0 4 0 305 -3.1 0 -2.9 -3.3 11/11/2005 16:40:00 10.2 0.9 12.6 8.4 10.4 1 13.3 8.4 358 6 5 305 -3 0 -2.7 -3.1 11/11/2005 16:50:00 11.4 0.9 13.3 8.8 11.8 0.9 13.7 8.8 359 4 359 305 -3.1 0 -2.7 -3.1 11/11/2005 17:00:00 12.7 0.8 14.5 10.7 13 1 14.9 10.7 5 4 3 305 -3.1 0 -2.9 -3.3 11/11/2005 17:10:00 13 0.8 14.9 10.7 13.3 0.9 14.9 10.7 1 4 7 305 -3.1 0 -2.9 -3.3 11/11/2005 17:20:00 11.8 0.8 13.7 9.1 12.1 0.9 14.1 9.1 355 5 2 305 -3.2 0 -3.1 -3.3 11/11/2005 17:30:00 11.6 0.8 13.7 9.1 11.9 0.9 14.1 8.8 353 5 354 305 -3.2 0 -3.1 -3.3 11/11/2005 17:40:00 11.4 0.9 13.3 9.1 11.7 1 13.7 9.1 355 4 352 305 -3.2 0 -3.1 -3.3 11/11/2005 17:50:00 11.3 0.8 13.3 9.1 11.6 0.8 13.7 9.5 355 4 357 305 -3.2 0 -3.1 -3.3 11/11/2005 18:00:00 11.1 0.7 12.6 9.5 11.4 0.7 13.3 9.5 357 5 4 305 -3.1 0 -2.9 -3.3 11/11/2005 18:10:00 11.6 0.7 13.3 9.5 11.9 0.8 13.3 9.9 0 6 5 305 -3.1 0 -2.9 -3.3 11/11/2005 18:20:00 12 0.7 13.7 9.9 12.2 0.8 14.1 10.3 359 3 2 305 -3.1 0.1 -2.9 -3.3 11/11/2005 18:30:00 11.6 0.7 13.3 9.5 11.8 0.9 14.1 9.5 5 4 5 305 -3.2 0 -3.1 -3.3 11/11/2005 18:40:00 10.8 0.8 12.6 8 11.1 0.8 13 8.4 2 4 358 305 -3.1 0 -2.9 -3.3 11/11/2005 18:50:00 11.2 0.7 13.3 9.5 11.5 0.7 13.7 9.5 1 3 1 305 -3.1 0 -2.9 -3.3 11/11/2005 19:00:00 11.1 0.7 13 8.8 11.4 0.8 13.3 9.1 2 3 0 305 -3.1 0 -2.9 -3.3 11/11/2005 19:10:00 11.2 0.8 13 8.8 11.5 0.8 13.3 8.8 1 5 353 305 -2.9 0 -2.7 -3.1 11/11/2005 19:20:00 10.9 0.7 12.6 9.1 11.1 0.7 13 9.5 1 4 0 305 -2.9 0 -2.7 -3.1 11/11/2005 19:30:00 10.6 0.7 12.2 8.8 10.9 0.8 13 8.4 359 4 357 305 -2.9 0 -2.7 -3.1 11/11/2005 19:40:00 11.2 0.7 12.6 9.5 11.5 0.8 13.3 9.5 358 4 0 305 -2.8 0 -2.7 -3.1 11/11/2005 19:50:00 12.1 0.8 13.7 10.3 12.4 0.9 14.5 9.5 0 4 3 305 -2.8 0 -2.7 -3.1 11/11/2005 20:00:00 11.7 0.8 13.3 9.1 11.9 0.9 14.1 9.1 4 4 7 305 -2.8 0 -2.7 -3.1 11/11/2005 20:10:00 10.3 0.6 11.8 8.8 10.5 0.7 12.2 8.8 2 5 6 305 -2.8 0 -2.7 -3.1 11/11/2005 20:20:00 10.9 0.7 12.6 8.8 11 0.9 12.6 8.4 8 4 1 305 -2.9 0 -2.7 -3.1 11/11/2005 20:30:00 11.7 0.7 13.7 9.5 11.9 0.9 14.1 9.1 5 4 359 305 -3 0 -2.7 -3.1 11/11/2005 20:40:00 11.3 0.9 13.7 8.8 11.5 1.1 13.7 8.4 4 4 4 305 -3 0 -2.7 -3.1 11/11/2005 20:50:00 11 0.6 12.2 9.1 11.3 0.7 12.6 9.1 7 4 3 305 -2.9 0 -2.7 -3.1 11/11/2005 21:00:00 10.6 0.7 12.2 9.1 10.9 0.7 12.6 9.1 4 5 6 305 -2.9 0 -2.7 -3.1 11/11/2005 21:10:00 10.4 0.7 12.2 8.8 10.7 0.8 13 8.8 0 5 3 305 -2.8 0 -2.7 -2.9 11/11/2005 21:20:00 10.4 0.6 11.8 8.8 10.6 0.7 12.6 8.4 4 5 9 305 -2.8 0 -2.7 -2.9 11/11/2005 21:30:00 11.1 0.7 12.6 8.8 11.3 0.7 13 9.5 4 4 3 305 -2.8 0 -2.7 -2.9 11/11/2005 21:40:00 11.1 0.7 12.6 9.1 11.3 0.8 13.3 9.5 4 5 359 305 -2.7 0 -2.4 -2.9 11/11/2005 21:50:00 10.5 0.7 12.2 8.4 10.7 0.8 12.6 8.4 5 5 4 305 -2.6 0 -2.4 -2.7 11/11/2005 22:00:00 10.5 0.6 11.8 8.8 10.8 0.7 12.6 8.4 0 4 358 305 -2.7 0 -2.7 -2.7 11/11/2005 22:10:00 10.9 0.9 13.3 8.4 11.1 1 13.3 8.4 3 5 4 305 -2.7 0 -2.4 -2.7 11/11/2005 22:20:00 11.4 0.7 13 9.1 11.7 0.8 13.3 9.1 359 3 0 305 -2.8 0 -2.7 -2.9 11/11/2005 22:30:00 10.6 0.8 12.6 7.6 10.9 0.9 12.6 7.6 355 3 2 305 -2.7 0 -2.4 -2.9 11/11/2005 22:40:00 10.4 0.7 12.2 8.4 10.7 0.8 13 8.8 4 6 3 305 -2.7 0 -2.4 -2.7 11/11/2005 22:50:00 11.2 0.7 13 9.1 11.5 0.9 13.3 8.8 1 5 3 305 -2.7 0 -2.4 -2.7 11/11/2005 23:00:00 11 0.7 12.2 8.8 11.3 0.7 13 8.8 359 4 359 305 -2.7 0 -2.4 -2.9 11/11/2005 23:10:00 9.9 0.8 11.8 7.6 10.2 0.9 12.2 8 1 4 7 305 -2.7 0 -2.4 -2.9 11/11/2005 23:20:00 10.1 0.8 11.8 8 10.4 0.9 12.2 8 358 3 358 305 -2.8 0 -2.4 -2.9 11/11/2005 23:30:00 10.3 0.9 12.6 7.6 10.6 1 13 7.6 355 5 353 305 -2.8 0 -2.7 -2.9 11/11/2005 23:40:00 10.4 0.6 11.5 8.8 10.7 0.7 12.2 8.8 352 3 354 305 -2.8 0 -2.7 -2.9 11/11/2005 23:50:00 10.7 0.8 12.6 8.8 11.1 0.9 14.1 8.4 356 4 352 305 -2.8 0 -2.4 -2.9 11/12/2005 00:00:00 10.8 0.7 12.6 8.4 11.2 0.8 12.6 8.8 358 5 353 305 -2.7 0 -2.2 -2.7 11/12/2005 00:10:00 11.1 0.6 12.6 9.5 11.4 0.8 13.3 9.1 1 3 2 305 -2.7 0 -2.4 -2.7 11/12/2005 00:20:00 10.4 0.6 11.8 8.4 10.6 0.7 12.6 8.8 359 5 2 305 -2.7 0 -2.4 -2.7 11/12/2005 00:30:00 10.5 0.8 12.6 8.4 10.8 0.8 12.6 8.8 2 4 0 305 -2.7 0 -2.4 -2.7 11/12/2005 00:40:00 10.2 0.7 12.2 8.4 10.4 0.8 12.6 8 6 6 9 305 -2.6 0 -2.4 -2.7 11/12/2005 00:50:00 10.4 0.7 11.8 8 10.7 0.8 12.6 8.4 2 5 12 305 -2.7 0 -2.4 -2.7 11/12/2005 01:00:00 10.4 0.9 12.2 8.4 10.7 0.9 12.6 7.6 1 5 1 305 -2.7 0 -2.4 -2.9 11/12/2005 01:10:00 10.1 0.9 12.6 8.4 10.4 1 13 8 3 4 2 305 -2.7 0 -2.4 -2.7 11/12/2005 01:20:00 10.4 0.7 12.2 8.8 10.6 0.8 12.6 8.4 3 4 358 305 -2.7 0 -2.4 -2.7 11/12/2005 01:30:00 9.8 0.6 11.5 8 10.1 0.6 11.5 8.4 0 3 359 305 -2.7 0 -2.4 -2.7 11/12/2005 01:40:00 9.6 0.7 11.1 7.6 9.9 0.7 11.5 7.2 2 4 8 305 -2.6 0 -2.4 -2.7 11/12/2005 01:50:00 9.5 0.6 11.1 8 9.8 0.6 11.5 8 2 5 4 305 -2.7 0 -2.4 -2.7 11/12/2005 02:00:00 9.5 0.6 11.5 8 9.8 0.7 11.5 7.6 359 5 3 305 -2.6 0 -2.4 -2.7 11/12/2005 02:10:00 9.3 0.6 10.7 7.6 9.5 0.7 11.5 7.2 0 4 356 305 -2.6 0 -2.4 -2.7 11/12/2005 02:20:00 9.9 0.8 11.5 7.6 10.2 0.9 12.2 8 359 4 358 305 -2.7 0 -2.4 -2.7 11/12/2005 02:30:00 9.5 0.8 11.1 6.8 9.8 0.9 11.8 6.8 2 4 3 305 -2.7 0 -2.4 -2.7 11/12/2005 02:40:00 9.7 0.8 11.5 7.2 10 0.9 12.2 7.6 4 4 8 305 -2.7 0 -2.4 -2.7 11/12/2005 02:50:00 8.9 1 11.5 6.1 9.2 1 11.8 6.5 3 4 2 305 -2.7 0 -2.4 -2.7 11/12/2005 03:00:00 9.1 1.1 11.5 6.5 9.4 1.2 12.2 6.5 359 5 354 305 -2.7 0 -2.4 -2.7 11/12/2005 03:10:00 9.1 0.8 11.5 7.2 9.4 0.8 12.2 7.2 3 6 359 305 -2.6 0 -2.4 -2.7 11/12/2005 03:20:00 9 0.7 10.7 7.2 9.3 0.7 11.1 7.2 0 5 5 305 -2.6 0 -2.4 -2.7 11/12/2005 03:30:00 9.6 0.6 11.1 7.6 9.9 0.7 11.5 8 0 4 3 305 -2.6 0 -2 -2.7 11/12/2005 03:40:00 9.5 0.6 11.1 8 9.7 0.6 11.5 8 1 5 357 305 -2.6 0 -2.4 -2.7 11/12/2005 03:50:00 8.9 0.9 11.1 6.8 9.1 1 11.5 7.2 7 4 6 305 -2.6 0 -2 -2.7 11/12/2005 04:00:00 8.8 0.7 10.7 7.2 9 0.7 11.1 7.2 7 5 2 305 -2.6 0 -2.4 -2.7 11/12/2005 04:10:00 7.9 0.6 9.9 6.5 8.2 0.7 10.7 6.5 356 7 354 305 -2.6 0 -2.4 -2.7 11/12/2005 04:20:00 9.1 0.7 10.7 7.2 9.4 0.7 11.1 6.8 1 6 8 305 -2.5 0 -2.4 -2.7 11/12/2005 04:30:00 8.7 0.8 10.7 6.8 9 0.8 11.1 6.8 356 5 0 305 -2.6 0 -2.4 -2.7 11/12/2005 04:40:00 9.3 0.6 11.5 7.6 9.6 0.7 11.5 7.2 356 4 352 305 -2.6 0 -2.4 -2.7 11/12/2005 04:50:00 8.5 0.7 9.9 6.8 8.8 0.8 10.7 6.5 353 5 3 305 -2.7 0 -2.4 -2.7 11/12/2005 05:00:00 9.5 0.8 11.5 6.8 9.8 0.9 11.8 7.2 358 4 351 305 -2.6 0 -2.4 -2.7 11/12/2005 05:10:00 9 0.7 10.7 7.2 9.3 0.8 11.5 7.2 358 5 350 305 -2.6 0 -2.4 -2.7 11/12/2005 05:20:00 9 0.6 10.3 7.2 9.2 0.7 10.7 7.2 0 5 357 305 -2.6 0 -2.4 -2.7 11/12/2005 05:30:00 8.6 0.6 9.9 6.8 8.9 0.7 10.3 7.2 2 4 8 305 -2.7 0 -2.4 -2.7 11/12/2005 05:40:00 8.6 0.9 10.7 6.8 8.8 0.9 11.1 6.8 357 5 352 305 -2.7 0 -2.4 -2.7 11/12/2005 05:50:00 8.2 0.6 9.5 6.5 8.6 0.6 9.9 6.8 0 4 355 305 -2.7 0 -2.4 -2.7 11/12/2005 06:00:00 8.6 0.9 10.7 6.5 8.9 1 11.5 6.8 0 5 3 305 -2.6 0 -2.4 -2.7 11/12/2005 06:10:00 7.7 0.7 9.5 6.1 8 0.7 9.5 6.5 3 7 359 305 -2.7 0 -2.4 -2.7 11/12/2005 06:20:00 8.8 0.6 10.3 7.6 9 0.6 10.7 7.6 359 5 0 305 -2.6 0 -2 -2.7 11/12/2005 06:30:00 8.8 0.7 10.3 6.5 9.1 0.7 11.1 6.8 351 6 348 305 -2.7 0 -2.4 -2.7 11/12/2005 06:40:00 9.1 0.5 10.3 7.6 9.3 0.6 10.7 8 356 6 356 305 -2.6 0 -2.4 -2.7 11/12/2005 06:50:00 9.4 0.7 11.5 7.6 9.8 0.8 11.8 8 354 5 349 305 -2.7 0 -2.4 -2.7 11/12/2005 07:00:00 9.5 0.9 11.5 7.6 9.8 0.9 12.2 8 352 7 350 305 -2.7 0 -2.4 -2.7 11/12/2005 07:10:00 9.1 0.5 10.7 8 9.4 0.6 10.7 8 0 4 5 305 -2.6 0 -2.4 -2.7 11/12/2005 07:20:00 9.5 0.7 11.5 8 9.8 0.8 12.2 7.6 358 6 351 305 -2.5 0 -2.4 -2.7 11/12/2005 07:30:00 9.5 0.8 11.8 7.2 9.8 0.8 11.8 7.6 355 5 358 305 -2.7 0 -2.4 -2.7 11/12/2005 07:40:00 9.2 0.6 10.7 7.6 9.6 0.6 11.5 7.2 356 3 356 305 -2.6 0 -2.4 -2.7 11/12/2005 07:50:00 9.2 0.8 11.5 6.8 9.5 0.9 11.8 7.2 357 8 359 305 -2.6 0 -2.4 -2.7 11/12/2005 08:00:00 9.5 1 12.2 7.6 9.8 1 13 8 353 4 2 305 -2.6 0 -2.4 -2.7 11/12/2005 08:10:00 8.8 0.6 10.7 6.5 9 0.7 11.1 7.2 352 4 345 305 -2.7 0 -2.4 -2.7 11/12/2005 08:20:00 8.9 0.9 10.7 6.5 9.1 1 11.1 6.8 353 4 357 305 -2.7 0 -2.4 -2.7 11/12/2005 08:30:00 9.4 1 11.8 7.2 9.6 1 12.2 7.2 357 4 3 305 -2.7 0 -2.4 -2.9 11/12/2005 08:40:00 9.7 0.6 11.1 8.4 10 0.6 11.5 8.4 354 4 355 305 -2.7 0 -2.7 -2.9 11/12/2005 08:50:00 9.8 0.6 11.5 8 10.1 0.7 12.2 8.4 353 5 350 305 -2.8 0 -2.7 -2.9 11/12/2005 09:00:00 10.1 0.5 11.5 8.8 10.3 0.6 11.8 8.8 357 4 351 305 -2.8 0 -2.7 -2.9 11/12/2005 09:10:00 10.1 0.7 11.8 8 10.4 0.7 12.2 8.8 354 4 355 305 -2.8 0 -2.4 -2.9 11/12/2005 09:20:00 9.6 0.5 10.7 8 9.8 0.6 11.1 8 356 4 351 305 -2.8 0 -2.7 -2.9 11/12/2005 09:30:00 10 0.7 11.8 8 10.3 0.8 12.2 8.4 358 5 354 305 -2.8 0 -2.4 -2.9 11/12/2005 09:40:00 9.6 0.7 11.5 7.6 9.9 0.7 11.1 8 0 5 357 305 -2.8 0 -2.4 -2.9 11/12/2005 09:50:00 9.5 0.7 11.1 6.8 9.7 0.7 11.1 7.2 359 3 4 305 -2.8 0 -2.7 -3.1 11/12/2005 10:00:00 9.5 0.6 11.1 7.6 9.8 0.7 11.5 6.8 0 4 6 305 -2.8 0 -2.7 -3.1 11/12/2005 10:10:00 9.5 0.6 11.5 7.6 9.8 0.7 11.8 7.6 1 4 358 305 -2.8 0 -2.7 -3.1 11/12/2005 10:20:00 9.5 0.7 11.1 7.6 9.8 0.8 11.5 7.6 4 3 4 305 -2.8 0 -2.7 -2.9 11/12/2005 10:30:00 9.1 0.7 10.7 7.2 9.3 0.8 11.1 7.2 4 4 0 305 -2.8 0 -2.7 -2.9 11/12/2005 10:40:00 9.3 0.6 10.3 7.6 9.6 0.6 11.1 7.6 355 5 3 305 -2.9 0 -2.7 -3.1 11/12/2005 10:50:00 8.7 0.5 9.9 6.8 9 0.6 10.3 6.8 357 5 358 305 -2.8 0 -2.4 -3.1 11/12/2005 11:00:00 8.8 0.7 10.3 6.8 9.1 0.7 10.7 6.5 1 3 2 305 -2.7 0 -2.4 -2.9 11/12/2005 11:10:00 9.2 0.5 11.1 7.6 9.4 0.6 11.5 8 2 4 6 305 -2.7 0 -2.7 -2.7 11/12/2005 11:20:00 9.3 0.5 10.7 8 9.5 0.6 11.1 8 3 5 5 305 -2.8 0 -2.7 -2.9 11/12/2005 11:30:00 8.6 0.5 9.9 7.2 8.9 0.6 10.3 7.2 358 5 353 305 -2.8 0 -2.7 -2.9 11/12/2005 11:40:00 8.6 0.5 9.5 7.2 8.8 0.6 9.9 7.2 0 4 0 305 -2.8 0 -2.7 -2.9 11/12/2005 11:50:00 9 0.5 9.9 7.2 9.3 0.5 10.7 7.6 356 4 353 305 -2.8 0 -2.7 -2.9 11/12/2005 12:00:00 9 0.6 10.3 7.2 9.4 0.7 10.7 7.2 1 4 2 305 -2.8 0 -2.7 -2.9 11/12/2005 12:10:00 9.4 0.6 10.7 7.6 9.7 0.7 11.5 7.2 357 3 359 305 -2.8 0 -2.7 -2.9 11/12/2005 12:20:00 9 0.6 10.3 6.8 9.3 0.6 10.7 7.2 357 4 358 305 -2.8 0 -2.7 -3.1 11/12/2005 12:30:00 8.7 0.6 9.9 6.8 9.1 0.7 10.7 7.2 355 4 354 305 -2.8 0 -2.7 -3.1 11/12/2005 12:40:00 9 0.6 10.3 6.8 9.2 0.7 10.7 6.5 355 4 357 305 -2.8 0 -2.7 -2.9 11/12/2005 12:50:00 8.8 0.6 11.1 7.2 9.1 0.7 11.5 7.2 359 6 351 305 -2.7 0 -2.4 -2.7 11/12/2005 13:00:00 8.9 0.7 10.7 7.2 9.2 0.7 11.1 7.2 358 4 357 305 -2.6 0 -2.4 -2.7 11/12/2005 13:10:00 9.4 0.8 11.1 6.8 9.6 0.8 11.5 7.2 2 5 1 305 -2.5 0 -2.4 -2.7 11/12/2005 13:20:00 9.8 0.5 11.1 8.4 10.1 0.6 11.5 8 1 4 355 305 -2.6 0 -2.4 -2.7 11/12/2005 13:30:00 9.4 0.6 10.7 7.6 9.7 0.7 11.1 8 359 4 357 305 -2.6 0 -2.4 -2.7 11/12/2005 13:40:00 9.5 0.6 10.7 8 9.8 0.6 11.5 8 357 4 353 305 -2.6 0 -2.4 -2.7 11/12/2005 13:50:00 9.8 0.5 11.1 8.4 10 0.6 11.5 8.4 2 3 4 305 -2.4 0 -2.2 -2.7 11/12/2005 14:00:00 9.9 0.8 11.5 8 10.1 0.8 11.8 8 5 3 9 305 -2.4 0 -2.2 -2.7 11/12/2005 14:10:00 10.1 0.6 11.5 8.4 10.3 0.6 11.8 8 4 3 359 305 -2.5 0 -2.4 -2.7 11/12/2005 14:20:00 9.5 0.6 11.1 7.6 9.8 0.6 11.5 8 1 4 359 305 -2.5 0 -2.4 -2.7 11/12/2005 14:30:00 9.5 0.7 10.7 7.6 9.8 0.8 11.8 7.6 359 4 9 305 -2.5 0 -2.4 -2.7 11/12/2005 14:40:00 9 0.6 10.3 6.8 9.2 0.6 10.3 7.2 359 4 356 305 -2.6 0 -2.4 -2.7 11/12/2005 14:50:00 9.3 0.6 10.7 7.6 9.5 0.6 11.1 7.6 0 3 357 305 -2.5 0 -2 -2.7 11/12/2005 15:00:00 9.5 0.6 10.7 7.6 9.8 0.6 11.1 8.4 1 3 0 305 -2.6 0 -2.4 -2.7 11/12/2005 15:10:00 8.6 0.5 9.5 6.8 8.9 0.6 9.9 6.5 0 5 2 305 -2.6 0 -2 -2.7 11/12/2005 15:20:00 8.4 0.5 9.5 6.8 8.7 0.6 9.9 6.8 358 4 358 305 -2.6 0 -2.4 -2.7 11/12/2005 15:30:00 8.4 0.6 9.5 6.5 8.7 0.7 10.3 6.5 359 5 353 305 -2.6 0 -2.4 -2.7 11/12/2005 15:40:00 8.8 0.7 10.3 6.8 9.1 0.7 10.7 6.8 2 5 359 305 -2.6 0 -2 -2.7 11/12/2005 15:50:00 9.1 0.4 10.3 8 9.4 0.5 10.7 7.2 359 4 357 305 -2.6 0 -2.4 -2.7 11/12/2005 16:00:00 8.7 0.6 9.9 6.5 9 0.7 10.7 6.5 359 4 359 305 -2.6 0 -2.4 -2.7 11/12/2005 16:10:00 8.7 0.6 9.9 7.2 8.9 0.6 10.3 6.8 0 4 358 305 -2.6 0 -2.4 -2.7 11/12/2005 16:20:00 9.1 0.6 10.3 7.2 9.3 0.7 11.1 7.2 359 7 351 305 -2.6 0 -2.4 -2.7 11/12/2005 16:30:00 8.9 0.5 10.3 7.2 9.1 0.6 10.7 6.8 356 4 353 305 -2.5 0 -2.4 -2.7 11/12/2005 16:40:00 8.6 0.6 9.9 6.8 8.8 0.6 9.9 6.8 6 5 3 305 -2.4 0 -2.2 -2.7 11/12/2005 16:50:00 8.9 0.5 9.9 7.2 9.1 0.6 10.3 7.6 6 5 11 305 -2.5 0 -2 -2.7 11/12/2005 17:00:00 9.1 0.6 10.7 7.6 9.3 0.7 10.7 7.6 5 4 356 305 -2.5 0 -2.4 -2.7 11/12/2005 17:10:00 8.8 0.6 9.9 6.8 9 0.7 10.3 6.5 7 3 6 305 -2.4 0 -2.2 -2.7 11/12/2005 17:20:00 8.8 0.7 10.3 7.2 9.1 0.7 10.7 7.2 6 3 9 305 -2.4 0 -2.2 -2.7 11/12/2005 17:30:00 8.5 0.5 9.5 6.8 8.8 0.5 9.9 7.2 6 4 11 305 -2.4 0 -2.2 -2.7 11/12/2005 17:40:00 8.9 0.5 10.7 7.6 9.1 0.6 10.7 7.6 6 3 7 305 -2.3 0 -2.2 -2.4 11/12/2005 17:50:00 8.8 0.6 10.3 6.8 9 0.6 10.3 6.1 12 3 13 305 -2.3 0 -2.2 -2.4 11/12/2005 18:00:00 8.6 0.6 9.9 6.5 8.9 0.7 10.3 6.5 14 3 10 305 -2.3 0 -2.2 -2.4 11/12/2005 18:10:00 8.7 0.5 9.9 7.2 8.9 0.5 10.3 7.2 11 8 10 305 -2.4 0 -2.2 -2.7 11/12/2005 18:20:00 7.5 0.7 9.5 5.7 7.8 0.8 9.9 5.7 15 6 17 305 -2.4 0 -2.4 -2.7 11/12/2005 18:30:00 8.1 0.5 9.1 6.5 8.4 0.5 9.5 6.8 2 4 3 305 -2.6 0.1 -2.2 -2.7 11/12/2005 18:40:00 7.2 0.6 8.4 5.7 7.5 0.6 8.8 5.7 1 4 2 305 -2.6 0 -2.4 -2.7 11/12/2005 18:50:00 7.1 0.5 8.8 5.3 7.3 0.6 9.1 5.7 0 5 8 305 -2.6 0 -2 -2.7 11/12/2005 19:00:00 7.6 0.7 9.1 5.7 7.8 0.8 9.1 6.1 5 5 4 305 -2.5 0 -2.4 -2.7 11/12/2005 19:10:00 8.7 0.6 9.9 7.2 9 0.6 10.7 6.8 4 5 10 305 -2.6 0 -2.4 -2.7 11/12/2005 19:20:00 8.5 0.6 10.3 6.8 8.8 0.6 10.7 7.2 1 4 359 305 -2.7 0 -2 -2.7 11/12/2005 19:30:00 8.7 0.6 9.9 6.5 9 0.7 10.7 6.8 2 5 358 305 -2.7 0 -2.4 -2.7 11/12/2005 19:40:00 8.6 0.6 9.9 6.8 8.9 0.6 10.3 7.2 359 4 346 305 -2.7 0 -2.4 -2.7 11/12/2005 19:50:00 8.9 0.6 10.3 7.6 9.2 0.6 10.7 7.6 1 3 1 305 -2.7 0 -2.4 -2.7 11/12/2005 20:00:00 9.3 0.6 10.7 7.6 9.5 0.7 11.1 7.6 8 4 7 305 -2.6 0 -2.4 -2.7 11/12/2005 20:10:00 8.6 0.6 9.9 6.8 8.9 0.6 10.3 7.2 8 4 12 305 -2.7 0 -2.4 -2.7 11/12/2005 20:20:00 8.2 0.5 9.1 6.5 8.4 0.6 9.5 6.5 8 4 7 305 -2.6 0 -2.4 -2.7 11/12/2005 20:30:00 7.9 0.5 9.1 6.1 8.1 0.6 9.1 6.5 9 3 10 305 -2.6 0 -2.4 -2.7 11/12/2005 20:40:00 7.6 0.4 8.4 6.5 7.8 0.5 9.1 5.7 10 3 3 305 -2.4 0 -2.2 -2.7 11/12/2005 20:50:00 8.7 1 10.3 6.5 8.8 1 10.7 6.5 17 4 18 305 -2.4 0 -2.2 -2.7 11/12/2005 21:00:00 8.9 0.5 10.3 7.2 9.1 0.5 10.7 7.6 14 3 16 305 -2.6 0 -2.4 -2.7 11/12/2005 21:10:00 8.7 0.5 9.9 6.8 8.9 0.6 10.7 6.8 13 3 15 305 -2.6 0 -2.4 -2.7 11/12/2005 21:20:00 8.8 0.6 10.3 7.2 8.9 0.7 10.3 7.2 13 4 12 305 -2.7 0 -2.4 -2.7 11/12/2005 21:30:00 8.9 0.6 10.3 7.6 9.1 0.6 10.7 7.2 10 4 9 305 -2.8 0 -2.4 -2.9 11/12/2005 21:40:00 8.5 0.6 10.3 6.5 8.7 0.6 10.7 6.8 9 4 15 305 -2.7 0 -2.4 -2.9 11/12/2005 21:50:00 8.4 0.5 9.5 6.8 8.6 0.5 9.9 6.8 13 3 8 305 -2.8 0 -2.2 -3.1 11/12/2005 22:00:00 8.6 0.5 9.9 7.2 8.8 0.6 10.3 7.2 7 4 11 305 -2.9 0 -2.7 -3.1 11/12/2005 22:10:00 8.4 0.6 9.5 6.8 8.6 0.6 9.9 6.8 3 5 8 305 -2.8 0 -2.7 -3.1 11/12/2005 22:20:00 8.2 0.5 9.1 6.8 8.5 0.6 9.5 6.8 1 4 358 305 -2.8 0 -2.4 -3.1 11/12/2005 22:30:00 8 0.5 9.1 6.8 8.3 0.6 9.9 6.8 358 4 352 305 -2.8 0 -2.4 -3.1 11/12/2005 22:40:00 8.7 0.5 9.9 7.2 8.9 0.6 10.3 7.2 3 3 4 305 -2.8 0 -2.4 -3.1 11/12/2005 22:50:00 8.8 0.5 9.9 7.6 9.1 0.5 10.3 7.6 4 4 3 305 -2.8 0 -2.4 -2.9 11/12/2005 23:00:00 9 0.5 9.9 7.2 9.3 0.5 10.7 7.6 5 3 9 305 -2.8 0 -2.4 -2.9 11/12/2005 23:10:00 8.8 0.6 9.9 6.8 9.1 0.6 10.3 6.8 4 3 9 305 -2.8 0 -2.4 -2.9 11/12/2005 23:20:00 8.3 0.6 9.5 6.5 8.5 0.6 9.9 6.5 5 5 3 305 -2.7 0 -2.4 -2.7 11/12/2005 23:30:00 8.1 0.5 9.1 6.8 8.3 0.6 9.9 6.5 3 3 0 305 -2.7 0 -2.4 -2.7 11/12/2005 23:40:00 7.8 0.5 9.1 6.5 8.1 0.6 9.5 6.8 8 6 8 305 -2.6 0 -2.4 -2.7 11/12/2005 23:50:00 7.5 0.4 8.8 6.5 7.7 0.4 9.1 6.5 8 4 14 305 -2.7 0 -2.4 -2.7 11/13/2005 00:00:00 7.3 0.5 8 6.1 7.5 0.6 8.8 6.1 10 3 8 305 -2.6 0 -2.4 -2.7 11/13/2005 00:10:00 6.7 0.5 8.4 5.3 7 0.5 8.4 5.7 5 4 5 305 -2.6 0 -2.4 -2.7 11/13/2005 00:20:00 6.7 0.4 7.6 5.3 7 0.5 8 5.7 359 5 356 305 -2.6 0 -2.4 -2.7 11/13/2005 00:30:00 6.6 0.5 8 4.9 6.9 0.5 8 5.3 1 4 356 305 -2.6 0 -2.4 -2.7 11/13/2005 00:40:00 7 0.3 8 6.1 7.3 0.4 8 6.5 354 5 357 305 -2.7 0 -2.4 -2.7 11/13/2005 00:50:00 6.8 0.4 8 5.7 7.1 0.5 8.4 5.7 2 4 2 305 -2.7 0 -2.4 -2.7 11/13/2005 01:00:00 6.9 0.6 8.8 5.3 7.1 0.6 9.1 5.7 3 5 4 305 -2.7 0 -2.7 -2.9 11/13/2005 01:10:00 7.1 0.4 8 5.7 7.4 0.5 8.4 6.1 2 4 352 305 -2.8 0 -2.7 -2.9 11/13/2005 01:20:00 7.1 0.5 8.4 5.7 7.3 0.6 8.8 5.3 7 4 8 305 -2.8 0 -2.4 -3.1 11/13/2005 01:30:00 7 0.4 8.4 5.7 7.3 0.5 8.4 5.7 4 4 0 305 -2.9 0 -2.7 -3.1 11/13/2005 01:40:00 7 0.5 8.8 5.7 7.3 0.6 8.4 5.7 2 4 359 305 -2.9 0 -2.7 -3.1 11/13/2005 01:50:00 6.6 0.6 8 5.3 6.9 0.6 8.4 5.3 0 4 4 305 -2.9 0 -2.7 -3.1 11/13/2005 02:00:00 6.9 0.3 7.6 6.1 7.1 0.4 8.4 6.1 2 4 0 305 -3 0 -2.7 -3.1 11/13/2005 02:10:00 6.8 0.4 8 5.7 7 0.5 8.4 5.7 3 5 8 305 -3 0 -2.9 -3.1 11/13/2005 02:20:00 6.7 0.5 8 5.3 6.8 0.6 8.4 5.3 5 4 4 305 -3 0 -2.7 -3.1 11/13/2005 02:30:00 6.7 0.4 7.6 5.3 6.9 0.5 8 5.7 3 5 1 305 -3 0 -2.7 -3.1 11/13/2005 02:40:00 7 0.5 8 5.3 7.1 0.5 8 5.7 6 4 5 305 -3 0 -2.9 -3.1 11/13/2005 02:50:00 7.2 0.4 8.4 6.1 7.5 0.5 8.4 6.1 3 3 6 305 -3 0 -2.4 -3.1 11/13/2005 03:00:00 7.5 0.5 9.1 6.1 7.7 0.5 9.5 6.5 8 4 4 305 -3.1 0 -2.9 -3.1 11/13/2005 03:10:00 7.4 0.4 8.4 6.1 7.6 0.4 8.4 6.5 10 3 11 305 -3.1 0 -2.9 -3.3 11/13/2005 03:20:00 7.3 0.4 8.4 6.1 7.5 0.4 8.4 6.1 13 4 12 305 -3.1 0 -3.1 -3.3 11/13/2005 03:30:00 6.7 0.5 8 5.3 6.8 0.5 8 5.3 12 5 22 305 -3.1 0 -2.9 -3.3 11/13/2005 03:40:00 6.7 0.5 8 5.3 6.9 0.6 8 5.3 17 4 21 305 -3.2 0 -3.1 -3.3 11/13/2005 03:50:00 6.4 0.5 8 4.9 6.6 0.5 8 5.3 16 5 21 305 -3.3 0 -3.1 -3.3 11/13/2005 04:00:00 6.7 0.5 8 5.3 6.9 0.5 8 5.7 16 3 15 305 -3.3 0 -3.1 -3.3 11/13/2005 04:10:00 6.4 0.6 7.6 4.9 6.6 0.7 8 4.6 11 5 14 305 -3.3 0 -3.1 -3.3 11/13/2005 04:20:00 6.1 0.5 7.6 4.9 6.3 0.5 7.6 4.9 11 6 26 305 -3.3 0 -3.1 -3.3 11/13/2005 04:30:00 5.9 0.5 7.2 4.6 6 0.5 7.6 4.6 11 4 9 305 -3.3 0 -3.1 -3.3 11/13/2005 04:40:00 6.3 0.4 7.2 4.9 6.4 0.4 7.6 5.3 12 4 9 305 -3.3 0 -3.1 -3.3 11/13/2005 04:50:00 6.1 0.4 7.2 5.3 6.3 0.5 7.2 4.9 12 4 15 305 -3.3 0 -3.1 -3.3 11/13/2005 05:00:00 5.9 0.5 7.2 4.9 6.1 0.5 7.6 4.9 14 5 22 305 -3.3 0 -3.1 -3.3 11/13/2005 05:10:00 5.6 0.4 6.8 4.6 5.8 0.5 6.8 4.6 10 5 17 305 -3.3 0 -3.1 -3.3 11/13/2005 05:20:00 5.4 0.4 6.5 3.8 5.5 0.4 6.5 4.2 7 4 7 305 -3.3 0 -3.1 -3.3 11/13/2005 05:30:00 5.3 0.5 6.5 4.2 5.4 0.5 6.8 3.8 11 7 19 305 -3.3 0 -3.1 -3.3 11/13/2005 05:40:00 5 0.6 6.1 3.8 5.1 0.6 6.5 3.8 12 5 14 305 -3.3 0 -3.1 -3.3 11/13/2005 05:50:00 4.9 0.6 6.5 3 5.2 0.6 6.5 3.4 16 8 23 305 -3.3 0 -3.3 -3.3 11/13/2005 06:00:00 4.6 0.6 6.1 3 4.8 0.6 6.5 3 12 8 6 305 -3.3 0 -3.1 -3.6 11/13/2005 06:10:00 4.5 0.4 5.3 3.4 4.6 0.4 5.7 3.8 12 4 16 305 -3.3 0 -3.3 -3.3 11/13/2005 06:20:00 4.6 0.5 6.1 3 4.7 0.6 6.5 3 355 9 353 305 -3.3 0 -3.3 -3.3 11/13/2005 06:30:00 4.8 0.4 6.1 3.8 5 0.5 6.1 3.8 2 8 353 305 -3.3 0 -3.1 -3.3 11/13/2005 06:40:00 4.3 0.6 6.1 3.4 4.5 0.6 6.5 3.4 353 5 353 305 -3.3 0 -3.1 -3.3 11/13/2005 06:50:00 4.2 0.5 5.3 3 4.4 0.6 5.7 3 5 6 4 305 -3.3 0 -3.1 -3.3 11/13/2005 07:00:00 4 0.7 5.3 1.9 4.2 0.7 5.7 3 358 11 355 305 -3.3 0 -3.1 -3.3 11/13/2005 07:10:00 4 0.6 6.1 2.6 4.4 0.5 5.7 3 357 5 359 305 -3.3 0 -3.1 -3.3 11/13/2005 07:20:00 4.2 0.5 5.3 2.6 4.5 0.5 5.3 3 2 7 10 305 -3.3 0 -3.1 -3.3 11/13/2005 07:30:00 4.1 0.6 6.1 2.6 4.5 0.5 6.5 3 0 5 3 305 -3.2 0 -3.1 -3.3 11/13/2005 07:40:00 4.1 0.6 5.7 2.6 4.4 0.6 6.1 3 347 9 343 305 -3.2 0 -3.1 -3.3 11/13/2005 07:50:00 4.5 0.7 6.1 2.6 4.7 0.7 6.1 3 324 15 306 305 -3.3 0 -3.1 -3.6 11/13/2005 08:00:00 3.9 1.1 6.5 1.9 4 1.2 6.8 1.9 319 14 338 305 -3.5 0 -3.3 -3.8 11/13/2005 08:10:00 3.4 0.7 4.6 1.5 3.7 0.8 5.3 2.3 348 11 341 305 -3.4 0 -3.3 -3.6 11/13/2005 08:20:00 2.5 0.5 3.8 1.1 2.7 0.5 3.8 1.5 333 12 327 305 -3.4 0 -3.3 -3.6 11/13/2005 08:30:00 2.6 0.6 4.2 1.5 2.9 0.6 4.6 1.9 10 11 19 305 -3.3 0 -3.3 -3.6 11/13/2005 08:40:00 1.9 1.1 4.9 0.4 2.1 1 5.3 0.7 346 26 315 305 -3.3 0 -3.3 -3.6 11/13/2005 08:50:00 3.9 0.4 4.6 3 4 0.4 4.9 3 319 11 310 305 -3.5 0 -3.3 -3.8 11/13/2005 09:00:00 3.1 0.6 4.9 1.9 3.4 0.6 4.9 2.3 333 10 318 305 -3.5 0 -3.3 -3.6 11/13/2005 09:10:00 2.5 1 4.9 0.7 2.7 0.9 4.9 1.5 313 6 315 305 -3.5 0 -3.3 -3.8 11/13/2005 09:20:00 1.9 0.8 3.8 0.7 2.2 0.7 3.8 1.1 306 3 303 305 -3.6 0 -3.3 -3.8 11/13/2005 09:30:00 1.7 1.1 3.8 0.4 2 1 4.2 0.4 324 17 336 305 -3.7 0 -3.6 -3.8 11/13/2005 09:40:00 2.9 0.5 4.2 1.5 3.2 0.6 4.6 1.9 346 6 346 305 -3.5 0 -3.3 -3.8 11/13/2005 09:50:00 2.1 0.6 3.4 0.7 2.4 0.5 3.8 1.5 355 9 358 305 -3.5 0 -3.3 -3.8 11/13/2005 10:00:00 2 0.6 3.4 0.7 2.3 0.6 4.2 1.1 357 11 343 305 -3.6 0 -3.3 -3.8 11/13/2005 10:10:00 1.5 0.4 2.6 0.4 1.9 0.4 2.6 0.7 9 11 4 305 -3.6 0 -3.3 -3.8 11/13/2005 10:20:00 1.3 0.5 2.3 0.4 1.7 0.4 2.6 0.7 334 16 0 305 -3.6 0.1 -3.3 -3.8 11/13/2005 10:30:00 1.1 0.5 2.3 0.4 1.5 0.5 2.3 0.4 323 17 321 305 -3.7 0 -3.6 -4 11/13/2005 10:40:00 1.3 0.4 2.6 0.7 1.5 0.3 2.6 0.7 305 8 324 305 -4 0.1 -3.8 -4.2 11/13/2005 10:50:00 1.3 0.7 3 0.4 1.5 0.6 2.6 0.4 315 8 310 305 -4.5 0.1 -4 -4.7 11/13/2005 11:00:00 1.5 0.5 3 0.4 1.6 0.4 2.3 0.7 298 12 285 305 -4.8 0 -4.5 -4.9 11/13/2005 11:10:00 2.2 0.7 3.8 1.1 2.1 0.6 3.4 1.1 292 10 300 305 -4.2 0.2 -3.8 -4.7 11/13/2005 11:20:00 2.5 0.6 3.8 0.4 2.3 0.6 3.8 0.7 290 9 305 305 -3.9 0 -3.8 -4 11/13/2005 11:30:00 1.3 0.7 3 0.4 1.5 0.6 3 0.4 297 8 291 305 -3.8 0.1 -3.6 -4 11/13/2005 11:40:00 1.1 0.7 2.6 0.4 1.1 0.7 2.3 0.4 299 13 312 305 -3.7 0.1 -3.3 -3.8 11/13/2005 11:50:00 2.2 0.4 3.4 1.1 2.4 0.5 3.4 1.1 314 6 302 305 -4 0 -3.8 -4.2 11/13/2005 12:00:00 2.2 0.5 3 0.7 2.2 0.4 3 1.5 306 22 330 305 -3.9 0.2 -3.6 -4.2 11/13/2005 12:10:00 2.5 0.5 3.4 1.1 2.1 0.5 3.4 0.7 282 18 268 305 -4.1 0 -3.8 -4.5 11/13/2005 12:20:00 2.8 0.5 3.8 1.9 2.8 0.4 3.4 1.9 305 9 285 305 -4 0 -3.6 -4.2 11/13/2005 12:30:00 2.2 0.4 3.4 1.5 2.3 0.3 3 1.5 308 6 316 305 -3.7 0 -3.6 -4 11/13/2005 12:40:00 2 0.7 3 0.4 2 0.5 2.6 0.7 292 8 282 305 -3.9 0 -3.8 -4 11/13/2005 12:50:00 1.5 0.5 2.6 0.4 1.4 0.4 2.3 0.7 300 8 287 305 -3.6 0.3 -2.7 -3.8 11/13/2005 13:00:00 2.8 0.6 3.8 1.5 2.5 0.6 3.4 1.1 292 6 291 305 -2.8 0 -2.4 -3.1 11/13/2005 13:10:00 2.2 0.5 3.4 1.1 1.9 0.4 3 0.7 281 14 274 305 -3.3 0 -3.1 -3.6 11/13/2005 13:20:00 2.9 0.6 4.2 1.5 2.5 0.6 3.8 1.1 278 7 291 305 -3.5 0 -3.1 -3.8 11/13/2005 13:30:00 2.6 0.4 3.4 1.5 2.3 0.3 3 1.5 286 8 275 305 -3.3 0 -3.1 -3.6 11/13/2005 13:40:00 2.8 0.3 3.8 2.3 2.6 0.3 3.4 1.9 292 8 291 305 -3.7 0.1 -3.3 -3.8 11/13/2005 13:50:00 2.9 0.5 4.2 1.5 2.8 0.5 4.2 1.5 293 9 298 305 -3.7 0 -3.3 -4 11/13/2005 14:00:00 3.2 0.6 4.9 1.9 3.1 0.6 4.9 1.9 299 9 301 305 -3.3 0.1 -3.1 -3.8 11/13/2005 14:10:00 3.2 0.4 4.6 2.3 3.2 0.4 4.2 2.3 307 7 302 305 -3.3 0.1 -2.9 -3.8 11/13/2005 14:20:00 2.9 0.6 4.6 1.5 3 0.6 4.2 1.9 304 10 303 305 -3.5 0 -3.3 -3.8 11/13/2005 14:30:00 2.9 0.5 4.2 2.3 3 0.4 3.8 2.3 302 6 294 305 -2.9 0.1 -2.7 -3.3 11/13/2005 14:40:00 3.2 0.5 4.2 2.3 3.1 0.5 4.2 1.9 296 11 316 305 -3 0.1 -2.7 -3.3 11/13/2005 14:50:00 3.5 0.5 4.9 2.3 3.4 0.4 4.9 2.6 298 11 293 305 -3.6 0.1 -3.1 -3.8 11/13/2005 15:00:00 3.1 0.3 3.8 2.3 2.8 0.5 3.8 1.5 292 13 279 305 -3.6 0 -3.3 -3.8 11/13/2005 15:10:00 3.4 0.6 4.6 2.3 3.5 0.5 4.6 2.3 309 11 310 305 -3.6 0 -3.3 -3.8 11/13/2005 15:20:00 2.7 0.4 3.4 1.5 2.6 0.4 3.4 1.5 301 10 310 305 -3.5 0 -3.3 -3.6 11/13/2005 15:30:00 1.7 0.5 2.6 0.7 1.6 0.4 2.6 0.7 296 14 296 305 -3.3 0 -3.1 -3.6 11/13/2005 15:40:00 3.2 1 5.3 1.1 3.1 1.1 4.9 0.7 299 9 293 305 -3.3 0 -3.1 -3.3 11/13/2005 15:50:00 3.3 0.7 5.3 1.9 3.3 0.7 4.9 1.9 297 8 293 305 -3.3 0 -3.1 -3.3 11/13/2005 16:00:00 2.8 0.7 4.2 1.9 2.7 0.7 4.2 1.5 296 8 305 305 -3.2 0 -3.1 -3.3 11/13/2005 16:10:00 4.4 0.5 5.7 3 4.2 0.4 5.3 3 301 10 288 305 -3.3 0 -3.1 -3.3 11/13/2005 16:20:00 5 0.5 6.8 3.8 4.8 0.5 6.5 3 299 8 301 305 -3.3 0 -3.1 -3.3 11/13/2005 16:30:00 3.5 0.7 5.7 1.9 3.2 0.6 4.9 1.9 289 9 277 305 -3.3 0 -3.3 -3.6 11/13/2005 16:40:00 3.3 1 4.9 1.5 2.8 0.8 4.6 1.1 279 8 279 305 -3.5 0 -3.3 -3.6 11/13/2005 16:50:00 3.6 0.7 5.7 1.9 2.9 0.6 4.9 1.1 279 9 281 305 -3.3 0 -3.3 -3.6 11/13/2005 17:00:00 3.1 1.1 5.7 1.5 2.6 1.1 5.3 1.1 271 13 283 305 -3.5 0 -3.3 -3.8 11/13/2005 17:10:00 1.5 0.6 3 0.4 1.3 0.5 2.6 0.4 263 12 281 305 -3.5 0 -3.3 -3.8 11/13/2005 17:20:00 2.2 0.8 4.2 0.4 1.7 0.5 3 0.4 262 11 259 305 -3.5 0 -3.3 -3.8 11/13/2005 17:30:00 2.7 0.9 4.9 1.1 2.2 0.8 4.2 0.7 264 12 253 305 -3.4 0 -3.3 -3.6 11/13/2005 17:40:00 4 0.9 6.1 1.5 3.6 0.8 5.3 1.5 287 13 283 305 -3.4 0 -3.3 -3.6 11/13/2005 17:50:00 3.7 0.7 5.7 2.3 3.3 0.7 5.3 1.5 289 12 302 305 -3.5 0 -3.3 -3.8 11/13/2005 18:00:00 3.6 0.7 5.3 2.6 3 0.7 4.6 1.9 276 7 276 305 -3.4 0 -3.3 -3.6 11/13/2005 18:10:00 3.8 0.8 5.7 1.9 3 0.7 4.6 1.5 260 12 251 305 -3.3 0 -3.3 -3.3 11/13/2005 18:20:00 3.7 0.4 4.9 2.3 2.9 0.5 4.6 1.9 264 8 252 305 -3.3 0 -3.1 -3.3 11/13/2005 18:30:00 4.9 0.6 6.5 3 4.2 0.7 5.3 2.3 280 10 283 305 -3.3 0 -3.1 -3.3 11/13/2005 18:40:00 3.5 0.7 5.3 1.9 3 0.7 4.6 1.9 267 13 273 305 -3.3 0 -3.3 -3.3 11/13/2005 18:50:00 4.6 0.8 6.5 2.3 4.1 0.9 5.7 1.9 273 14 285 305 -3.3 0 -3.3 -3.3 11/13/2005 19:00:00 4 0.6 5.7 2.3 3.6 0.6 4.9 1.9 247 8 257 305 -3.3 0 -3.1 -3.3 11/13/2005 19:10:00 3.9 0.6 5.3 2.3 3.5 0.6 4.9 1.9 252 9 250 305 -3.2 0 -3.1 -3.3 11/13/2005 19:20:00 3.1 0.5 4.2 2.3 2.7 0.4 3.8 1.9 250 9 254 305 -3.2 0 -3.1 -3.3 11/13/2005 19:30:00 2.7 0.5 4.2 1.9 2.5 0.4 3.4 1.5 240 7 251 305 -3.2 0 -2.7 -3.3 11/13/2005 19:40:00 2.1 0.6 3.4 0.7 2.1 0.5 3.4 1.1 239 10 237 305 -3.2 0 -3.1 -3.3 11/13/2005 19:50:00 3.7 1.1 6.8 1.9 3 1 6.5 1.1 259 10 247 305 -3 0 -2.7 -3.3 11/13/2005 20:00:00 3.7 1 6.1 2.3 3.4 0.8 5.7 1.9 249 10 250 305 -3 0 -2.7 -3.1 11/13/2005 20:10:00 3.6 0.8 5.7 1.9 3 0.7 4.6 1.5 260 13 261 305 -3 0 -2.9 -3.1 11/13/2005 20:20:00 3 0.7 4.9 1.1 2.7 0.7 4.2 1.1 243 13 231 305 -3 0 -2.9 -3.1 11/13/2005 20:30:00 3.9 0.7 5.7 2.6 3.5 0.6 5.3 2.3 244 9 236 305 -2.9 0 -2.7 -3.1 11/13/2005 20:40:00 4.5 0.9 6.5 1.9 3.7 0.8 5.3 1.9 271 15 269 305 -2.9 0 -2.7 -3.1 11/13/2005 20:50:00 2.6 0.8 4.6 0.7 2 0.5 3 0.7 264 8 269 305 -3 0 -2.9 -3.1 11/13/2005 21:00:00 2.9 0.6 3.8 1.9 2.4 0.7 3.8 0.7 254 9 251 305 -3 0 -2.7 -3.1 11/13/2005 21:10:00 4.2 1 6.8 2.6 3.5 0.7 6.1 2.3 248 9 251 305 -2.8 0 -2.7 -3.1 11/13/2005 21:20:00 5.3 0.9 6.8 2.6 4 0.8 6.1 2.3 267 10 250 305 -2.8 0 -2.7 -2.9 11/13/2005 21:30:00 4.7 0.6 6.8 2.6 3.7 0.6 5.3 2.3 271 8 265 305 -2.8 0 -2.7 -3.1 11/13/2005 21:40:00 3.9 0.8 6.1 2.3 3.2 0.8 5.3 1.5 258 11 275 305 -2.9 0 -2.7 -3.1 11/13/2005 21:50:00 4.6 0.5 6.1 3 3.7 0.6 5.3 2.3 259 9 268 305 -2.9 0 -2.7 -3.1 11/13/2005 22:00:00 3.5 0.5 4.9 2.3 3 0.5 4.2 1.5 253 11 244 305 -3 0 -2.9 -3.1 11/13/2005 22:10:00 3.6 0.9 5.7 1.9 3 0.8 4.9 1.5 257 9 265 305 -3 0 -2.9 -3.1 11/13/2005 22:20:00 4.8 0.6 6.1 3 4.1 0.6 6.1 2.3 249 10 249 305 -2.9 0 -2.7 -3.1 11/13/2005 22:30:00 5.4 0.6 6.8 3.8 4.4 0.7 6.1 2.6 273 9 281 305 -3 0 -2.9 -3.1 11/13/2005 22:40:00 5.2 0.6 6.5 3.8 4.1 0.6 5.7 2.6 260 7 261 305 -3.1 0 -3.1 -3.3 11/13/2005 22:50:00 4.3 0.5 5.3 3 3.9 0.5 5.3 2.3 246 5 245 305 -3.2 0 -3.1 -3.3 11/13/2005 23:00:00 3.3 0.4 4.6 2.6 3.1 0.5 4.2 1.9 246 10 234 305 -3.2 0 -3.1 -3.3 11/13/2005 23:10:00 2.2 0.6 3 0.4 2 0.6 3 0.7 251 23 231 305 -3.2 0 -3.1 -3.3 11/13/2005 23:20:00 2.3 0.6 3.8 0.7 2 0.6 3.4 0.7 256 10 252 305 -3.1 0 -2.9 -3.3 11/13/2005 23:30:00 3.4 0.8 5.7 2.3 2.8 0.8 5.3 1.5 271 12 287 305 -3 0 -2.7 -3.1 11/13/2005 23:40:00 3.9 0.8 5.7 1.9 3.2 0.7 4.6 1.5 259 11 265 305 -3 0 -2.7 -3.1 11/13/2005 23:50:00 4.2 0.5 5.3 3.4 3.8 0.5 5.3 2.6 236 9 252 305 -2.9 0 -2.7 -3.1 11/14/2005 00:00:00 4 0.5 5.3 3 3.5 0.5 5.3 2.3 240 8 239 305 -2.8 0 -2.4 -3.1 11/14/2005 00:10:00 4.6 1 6.8 1.9 4.2 0.8 6.1 1.5 230 12 244 305 -2.8 0 -2.7 -2.9 11/14/2005 00:20:00 2.6 0.7 4.9 0.7 2.5 0.7 4.6 1.1 237 10 236 305 -2.8 0 -2.7 -2.9 11/14/2005 00:30:00 3.7 1.2 6.5 0.7 3.1 1 5.3 0.7 252 12 247 305 -2.8 0 -2.7 -2.9 11/14/2005 00:40:00 4.5 0.6 5.7 2.6 3.6 0.6 5.7 2.3 261 11 256 305 -2.8 0 -2.7 -2.9 11/14/2005 00:50:00 4.7 0.6 6.1 2.6 4.1 0.7 5.7 1.5 277 11 273 305 -2.8 0 -2.7 -2.9 11/14/2005 01:00:00 4.1 0.7 5.7 2.3 3.5 0.6 4.9 1.1 274 15 263 305 -2.8 0 -2.7 -3.1 11/14/2005 01:10:00 3.3 1 5.3 1.1 2.7 0.6 4.2 1.5 271 12 268 305 -3 0 -2.7 -3.1 11/14/2005 01:20:00 2.3 0.8 3.8 0.4 2.2 0.6 3.8 0.7 245 14 245 305 -3 0 -2.9 -3.1 11/14/2005 01:30:00 2.9 0.5 4.9 1.5 2.6 0.5 3.8 1.5 246 8 258 305 -3 0 -2.7 -3.1 11/14/2005 01:40:00 4.7 1 6.5 2.6 4 1 6.1 1.9 277 8 284 305 -3 0 -2.7 -3.1 11/14/2005 01:50:00 3.2 0.6 4.9 1.9 2.8 0.7 4.2 1.5 255 13 278 305 -3 0 -2.7 -3.1 11/14/2005 02:00:00 3.6 1 6.5 1.1 3.2 0.9 5.3 1.1 249 12 251 305 -3 0 -2.7 -3.1 11/14/2005 02:10:00 2.4 0.7 4.2 1.1 2.1 0.6 4.2 1.1 247 4 257 305 -3 0 -2.9 -3.1 11/14/2005 02:20:00 4 0.6 5.3 2.3 3.6 0.6 4.9 1.9 234 15 223 305 -3 0 -2.9 -3.1 11/14/2005 02:30:00 4.3 0.6 6.1 3 3.7 0.6 5.3 2.3 250 12 282 305 -2.8 0 -2.7 -3.1 11/14/2005 02:40:00 3.3 0.7 4.9 1.9 3 0.7 4.6 1.9 238 8 244 305 -2.9 0 -2.7 -3.1 11/14/2005 02:50:00 4.8 0.9 7.6 2.6 4.3 0.7 6.5 2.6 247 23 259 305 -2.9 0 -2.7 -3.1 11/14/2005 03:00:00 4.1 0.6 5.7 3 3.5 0.6 4.9 1.9 262 17 269 305 -2.9 0 -2.7 -3.1 11/14/2005 03:10:00 3.6 0.7 5.3 2.6 2.8 0.6 4.6 1.5 269 9 256 305 -2.9 0 -2.7 -3.1 11/14/2005 03:20:00 3.2 0.6 4.2 1.5 2.5 0.4 3.4 1.5 275 13 263 305 -2.8 0 -2.7 -3.1 11/14/2005 03:30:00 4 0.7 5.7 2.6 4.2 0.7 5.7 3 318 8 322 305 -3 0 -2.7 -3.1 11/14/2005 03:40:00 4.6 0.5 5.7 3.8 4.9 0.5 6.1 3.8 327 6 326 305 -3.2 0 -3.1 -3.3 11/14/2005 03:50:00 4.6 0.4 5.7 3.4 4.9 0.5 6.1 3.4 337 6 339 305 -3.2 0 -2.7 -3.3 11/14/2005 04:00:00 4.5 0.4 5.7 3.4 4.9 0.4 6.1 3.4 341 4 337 305 -3.3 0 -3.1 -3.3 11/14/2005 04:10:00 4.4 0.4 5.7 3.4 4.8 0.5 6.1 3.4 344 5 342 305 -3.4 0 -3.3 -3.6 11/14/2005 04:20:00 4.1 0.5 5.3 3 4.5 0.5 5.7 3.4 341 6 336 305 -3.5 0 -3.3 -3.8 11/14/2005 04:30:00 3.9 0.5 4.9 2.6 4.3 0.4 5.7 3.4 349 5 347 305 -3.6 0 -3.3 -3.8 11/14/2005 04:40:00 4.4 0.5 5.3 3 4.7 0.5 6.1 3.4 343 5 346 305 -3.6 0 -3.3 -3.8 11/14/2005 04:50:00 3.7 0.6 4.9 2.3 3.9 0.6 5.3 2.6 346 8 350 305 -3.6 0 -3.3 -3.8 11/14/2005 05:00:00 3 0.6 4.6 1.9 3.4 0.5 4.9 2.3 350 8 343 305 -3.6 0 -3.6 -3.8 11/14/2005 05:10:00 4.1 0.4 4.9 3.4 4.4 0.4 5.3 3.4 334 5 334 305 -3.6 0 -3.6 -3.8 11/14/2005 05:20:00 4.5 0.6 6.1 3 4.7 0.6 6.1 3 341 6 345 305 -3.7 0 -3.3 -3.8 11/14/2005 05:30:00 4.7 0.5 5.7 3.4 4.9 0.5 6.1 3.4 342 7 343 305 -3.8 0 -3.6 -3.8 11/14/2005 05:40:00 4.4 0.4 5.3 3 4.5 0.4 5.7 3.4 350 5 348 305 -3.9 0 -3.8 -4 11/14/2005 05:50:00 4.2 0.6 5.3 2.6 4.3 0.6 5.7 3 356 5 356 305 -3.9 0 -3.8 -4 11/14/2005 06:00:00 3.9 0.6 5.3 1.9 4.1 0.6 5.3 2.6 359 7 0 305 -3.9 0 -3.8 -4 11/14/2005 06:10:00 3.2 0.4 4.2 2.3 3.6 0.4 4.9 2.6 0 8 6 305 -3.9 0 -3.8 -4 11/14/2005 06:20:00 3.6 0.5 4.9 2.3 3.9 0.6 5.3 2.3 345 10 333 305 -3.9 0 -3.8 -4 11/14/2005 06:30:00 4.5 0.6 6.5 3 4.9 0.6 6.5 3.4 346 6 348 305 -3.9 0 -3.8 -4 11/14/2005 06:40:00 4.7 0.6 5.7 3 5 0.6 6.1 3.4 348 9 352 305 -4 0 -3.8 -4.2 11/14/2005 06:50:00 5 0.5 6.5 3.4 5.2 0.5 6.5 3.4 340 7 339 305 -4 0 -3.8 -4.2 11/14/2005 07:00:00 5 0.5 6.8 3.4 5.3 0.5 6.5 4.2 350 9 0 305 -4.1 0 -3.8 -4.2 11/14/2005 07:10:00 5.3 0.6 6.8 3.8 5.6 0.6 7.2 3.8 355 7 345 305 -4.1 0 -4 -4.2 11/14/2005 07:20:00 5.3 0.7 6.8 3.8 5.6 0.7 7.2 4.2 346 6 351 305 -4.2 0 -4 -4.5 11/14/2005 07:30:00 5.3 0.5 6.8 4.2 5.6 0.6 7.2 4.2 352 6 350 305 -4.2 0 -4 -4.5 11/14/2005 07:40:00 4.6 0.8 6.1 3 4.7 0.8 6.5 3 1 9 5 305 -4.4 0 -4 -4.5 11/14/2005 07:50:00 3.4 0.8 5.7 1.9 3.6 0.8 5.7 2.3 348 22 339 305 -4.4 0 -4.2 -4.5 11/14/2005 08:00:00 2.3 0.6 3.8 1.1 2.6 0.6 4.2 1.5 328 10 354 305 -4.4 0 -4.2 -4.5 11/14/2005 08:10:00 2.4 1.1 4.6 0.4 2.7 1 4.6 0.7 332 15 329 305 -4.4 0 -4.2 -4.5 11/14/2005 08:20:00 2.2 0.5 3 0.7 2.4 0.5 3.4 0.7 334 23 358 305 -4.3 0 -4 -4.5 11/14/2005 08:30:00 2.6 0.6 4.6 1.5 2.7 0.6 4.9 1.5 327 17 355 305 -4.3 0 -4 -4.5 11/14/2005 08:40:00 3.3 0.8 5.7 1.1 3.5 0.8 6.1 1.5 338 13 358 305 -4.2 0 -4 -4.5 11/14/2005 08:50:00 4.7 0.9 7.2 2.6 5 1 7.6 2.6 355 11 6 305 -4 0 -3.8 -4.2 11/14/2005 09:00:00 3.9 0.9 6.5 1.9 4.1 1 7.2 2.3 348 12 2 305 -4.1 0 -4 -4.2 11/14/2005 09:10:00 4.7 0.7 6.5 3 5 0.7 6.5 3.4 347 7 347 305 -4 0 -3.8 -4.2 11/14/2005 09:20:00 5.5 0.8 7.2 3.8 5.9 0.8 7.6 4.2 352 8 355 305 -4 0 -3.8 -4 11/14/2005 09:30:00 6.3 1.1 9.5 4.2 6.5 1.2 9.9 4.2 348 7 352 305 -3.9 0 -3.8 -4 11/14/2005 09:40:00 7.2 0.9 8.8 4.9 7.4 0.9 9.1 5.3 351 5 345 305 -3.9 0 -3.8 -4 11/14/2005 09:50:00 8.2 0.6 9.5 6.5 8.5 0.7 9.9 6.5 349 4 354 305 -3.9 0 -3.8 -4 11/14/2005 10:00:00 9.3 0.7 11.1 6.8 9.6 0.8 11.5 7.2 351 3 355 305 -4 0 -3.8 -4.2 11/14/2005 10:10:00 9.8 0.6 11.1 7.6 10.1 0.7 11.5 8 354 5 356 305 -4.2 0 -4 -4.5 11/14/2005 10:20:00 10.2 0.7 12.2 8.4 10.5 0.7 12.2 8.8 357 5 1 305 -4.3 0 -4 -4.5 11/14/2005 10:30:00 10.4 0.6 11.8 8.8 10.7 0.6 12.2 8.4 356 5 352 305 -4.4 0 -4 -4.5 11/14/2005 10:40:00 10.5 0.8 11.8 7.6 10.7 0.8 12.2 7.6 359 4 358 305 -4.4 0 -4 -4.5 11/14/2005 10:50:00 10.9 0.6 12.6 8.8 11.2 0.6 12.6 9.1 2 4 359 305 -4.3 0.1 -4 -4.5 11/14/2005 11:00:00 10.8 0.7 12.6 9.1 11.1 0.8 13 9.1 5 4 8 305 -4.1 0 -3.8 -4.2 11/14/2005 11:10:00 11 0.7 12.6 9.1 11.2 0.8 13 9.1 8 3 9 305 -4.1 0 -3.8 -4.2 11/14/2005 11:20:00 11.5 0.7 13 9.5 11.7 0.8 13.3 9.1 6 4 10 305 -4.1 0 -3.8 -4.2 11/14/2005 11:30:00 11.2 0.6 13 9.1 11.4 0.7 13.3 8.4 8 4 0 305 -4 0 -3.8 -4.2 11/14/2005 11:40:00 11.7 0.7 13.3 9.5 11.9 0.8 13.7 9.1 8 3 5 305 -4.1 0 -3.8 -4.5 11/14/2005 11:50:00 12.1 0.7 13.7 9.9 12.3 0.8 14.1 9.9 6 3 9 305 -4.2 0 -3.8 -4.5 11/14/2005 12:00:00 11.5 0.7 13.3 9.1 11.7 0.7 13.7 9.9 7 3 3 305 -4.1 0 -3.8 -4.2 11/14/2005 12:10:00 11.3 0.6 12.6 8.8 11.5 0.8 13.3 8.8 8 4 9 305 -4.1 0 -3.8 -4.5 11/14/2005 12:20:00 11.1 0.6 12.6 8.4 11.3 0.7 13 8.4 12 3 12 305 -4.1 0 -3.8 -4.5 11/14/2005 12:30:00 11.2 0.6 13 9.1 11.3 0.8 13.3 8.8 9 4 9 305 -4.2 0 -4 -4.5 11/14/2005 12:40:00 10.9 0.8 13 8.4 11 0.9 13 8.8 10 4 6 305 -4.3 0 -4 -4.5 11/14/2005 12:50:00 10.9 0.5 12.2 8.8 11.1 0.6 13.3 8.8 10 3 11 305 -4.4 0 -4.2 -4.5 11/14/2005 13:00:00 10.7 0.7 12.2 8.8 10.9 0.8 12.6 8.8 9 5 9 305 -4.4 0 -4.2 -4.5 11/14/2005 13:10:00 10.6 0.9 12.6 8 10.8 1 13 8 10 4 7 305 -4.3 0 -4 -4.5 11/14/2005 13:20:00 11.7 0.7 13 8.8 11.8 0.8 13.7 8.8 10 3 4 305 -4.2 0 -4 -4.5 11/14/2005 13:30:00 11.3 0.6 13 9.9 11.5 0.7 13.7 9.5 7 4 5 305 -4.1 0 -3.8 -4.2 11/14/2005 13:40:00 11 0.6 12.2 8.8 11.3 0.7 13 9.1 7 4 12 305 -4 0 -3.8 -4.2 11/14/2005 13:50:00 11.5 0.6 13 9.9 11.7 0.7 13.3 9.5 8 3 8 305 -4.1 0 -4 -4.2 11/14/2005 14:00:00 11.2 0.7 12.6 9.1 11.4 0.8 13 9.1 9 4 10 305 -4.1 0 -3.8 -4.2 11/14/2005 14:10:00 11.7 0.9 13.7 9.1 11.9 1 14.1 9.1 7 3 7 305 -4.1 0 -3.8 -4.2 11/14/2005 14:20:00 12.1 0.8 13.7 9.1 12.3 1 14.1 8.8 9 3 11 305 -3.9 0 -3.6 -4 11/14/2005 14:30:00 12.5 1 14.5 9.1 12.6 1.1 14.9 8.8 10 4 11 305 -3.5 0 -3.3 -3.8 11/14/2005 14:40:00 13.2 0.8 15.6 10.7 13.2 0.9 15.3 10.7 14 3 15 305 -3.3 0 -3.1 -3.6 11/14/2005 14:50:00 13.1 0.8 14.9 10.3 13.2 1 15.3 10.3 13 3 14 305 -3.3 0 -3.1 -3.6 11/14/2005 15:00:00 13.9 0.9 15.6 11.1 13.9 0.9 16.1 11.5 17 4 13 305 -3.3 0 -3.1 -3.8 11/14/2005 15:10:00 14.4 0.9 16.4 11.8 14.4 0.9 16.1 11.8 16 4 14 305 -3.5 0.1 -3.1 -3.8 11/14/2005 15:20:00 14.3 1 16.4 11.1 14.3 1.1 17.2 11.1 14 4 14 305 -3.6 0.1 -3.3 -3.8 11/14/2005 15:30:00 13.8 0.9 16.1 10.7 14 1 16.1 10.7 14 5 12 305 -3.6 0 -3.3 -3.8 11/14/2005 15:40:00 13.5 0.7 15.3 11.8 13.4 0.9 16.1 10.3 15 4 12 305 -3.5 0 -3.3 -3.8 11/14/2005 15:50:00 13.2 0.8 14.9 10.7 13.2 0.9 14.9 10.7 17 4 17 305 -3.2 0 -3.1 -3.3 11/14/2005 16:00:00 13.3 0.8 14.9 11.1 13.3 0.8 15.3 10.7 16 3 19 305 -3.3 0 -3.1 -3.3 11/14/2005 16:10:00 12.1 0.7 13.7 10.3 12.2 0.8 13.7 9.9 16 4 12 305 -3.3 0 -3.1 -3.3 11/14/2005 16:20:00 12.4 0.9 14.5 9.5 12.5 1 14.5 9.5 14 3 17 305 -3.2 0 -3.1 -3.3 11/14/2005 16:30:00 12.2 1 14.5 9.1 12.3 1 14.1 9.5 13 3 16 305 -3.3 0 -3.1 -3.6 11/14/2005 16:40:00 12.4 1.1 14.9 9.5 12.5 1.2 14.9 9.5 14 4 21 305 -3.3 0.1 -3.1 -3.6 11/14/2005 16:50:00 13.3 0.8 14.9 11.1 13.3 1 15.3 10.7 15 4 11 305 -3.3 0 -3.1 -3.3 11/14/2005 17:00:00 13 0.6 14.5 11.5 12.9 0.8 14.5 10.3 15 3 18 305 -3.3 0 -3.1 -3.3 11/14/2005 17:10:00 12.6 0.8 14.1 9.9 12.7 0.9 14.5 10.3 13 3 12 305 -3.5 0 -3.1 -3.8 11/14/2005 17:20:00 12.9 1 15.3 9.5 13.1 1 15.3 9.9 12 3 17 305 -3.6 0 -3.3 -3.8 11/14/2005 17:30:00 13.3 1 15.3 10.3 13.4 1.1 15.6 9.9 15 4 17 305 -3.8 0 -3.6 -4 11/14/2005 17:40:00 13.8 1 16.1 11.1 13.9 1.1 16.4 11.1 15 3 16 305 -3.8 0 -3.3 -4 11/14/2005 17:50:00 13.3 0.8 14.5 10.7 13.4 0.9 14.9 10.3 19 4 18 305 -3.8 0 -3.6 -3.8 11/14/2005 18:00:00 12.8 1 14.9 9.9 13 1 15.6 10.3 17 5 20 305 -3.7 0 -3.6 -4 11/14/2005 18:10:00 11.9 0.8 13.3 9.5 12 0.9 13.7 9.5 9 5 9 305 -3.9 0 -3.8 -4 11/14/2005 18:20:00 12.3 0.9 14.5 9.5 12.5 1 14.9 9.5 11 4 8 305 -4 0 -3.8 -4.2 11/14/2005 18:30:00 12.5 0.9 14.5 9.9 12.7 1 14.5 9.9 7 4 2 305 -4 0 -3.8 -4 11/14/2005 18:40:00 12.6 1 14.9 9.9 12.8 1 15.3 10.3 10 4 7 305 -4 0 -3.8 -4 11/14/2005 18:50:00 12.7 0.8 14.5 9.9 12.9 0.9 14.9 9.5 10 4 9 305 -4 0 -3.8 -4 11/14/2005 19:00:00 12.5 0.8 14.1 9.9 12.7 0.9 14.5 9.9 7 4 5 305 -4 0 -3.8 -4.2 11/14/2005 19:10:00 12.6 0.9 14.5 9.9 12.9 1 14.9 9.1 6 5 9 305 -4 0 -3.8 -4.2 11/14/2005 19:20:00 13.4 0.9 15.3 10.3 13.6 1 16.1 10.7 10 4 4 305 -3.9 0 -3.8 -4 11/14/2005 19:30:00 13.4 1.1 16.1 10.3 13.4 1.1 16.1 9.9 7 4 7 305 -3.8 0 -3.6 -4 11/14/2005 19:40:00 13.7 1.2 15.6 10.3 13.8 1.2 16.1 10.7 7 4 10 305 -3.7 0 -3.3 -4 11/14/2005 19:50:00 13.5 0.9 15.3 10.3 13.7 1 15.6 11.1 10 3 12 305 -3.8 0 -3.6 -4 11/14/2005 20:00:00 12.7 1 15.3 9.1 12.8 1 14.9 9.1 11 4 8 305 -3.7 0 -3.3 -3.8 11/14/2005 20:10:00 12.3 0.8 15.3 10.3 12.5 1 15.6 10.3 10 5 11 305 -3.5 0 -3.3 -3.6 11/14/2005 20:20:00 12.1 0.8 14.1 9.5 12.3 0.8 14.5 9.9 12 5 10 305 -3.4 0 -3.1 -3.6 11/14/2005 20:30:00 12.2 0.9 14.1 9.5 12.3 1 14.5 9.5 12 4 19 305 -3.2 0 -3.1 -3.3 11/14/2005 20:40:00 13.1 0.8 14.5 9.9 13.2 0.9 14.9 10.3 12 3 14 305 -3.2 0 -3.1 -3.3 11/14/2005 20:50:00 12.5 0.8 14.1 9.9 12.6 0.9 14.5 9.9 12 4 13 305 -3.2 0 -3.1 -3.3 11/14/2005 21:00:00 12.5 0.9 14.5 9.1 12.7 0.9 14.5 9.1 6 4 5 305 -3.2 0.1 -2.9 -3.3 11/14/2005 21:10:00 13.2 0.7 14.9 11.1 13.4 0.8 15.3 11.1 4 4 358 305 -3.3 0 -3.1 -3.3 11/14/2005 21:20:00 13 1 14.9 10.3 13.1 1.1 15.3 10.3 3 5 7 305 -3.3 0 -3.1 -3.3 11/14/2005 21:30:00 12.8 1 15.3 9.5 12.9 1 15.3 9.9 3 5 3 305 -3.3 0 -3.1 -3.3 11/14/2005 21:40:00 13.1 0.9 14.9 9.9 13.3 1 15.3 10.3 3 5 0 305 -3.2 0 -2.9 -3.3 11/14/2005 21:50:00 13.1 0.8 14.9 10.7 13.2 1 15.6 10.3 4 4 6 305 -3.2 0 -3.1 -3.3 11/14/2005 22:00:00 13 0.9 15.3 10.3 13.2 0.9 15.3 10.7 5 4 4 305 -3.1 0 -2.7 -3.3 11/14/2005 22:10:00 13.9 0.9 16.1 11.5 14.1 1 16.1 11.5 3 4 1 305 -3 0 -2.7 -3.1 11/14/2005 22:20:00 13.6 1.2 16.1 9.9 13.8 1.2 16.4 10.3 5 4 4 305 -3 0 -2.7 -3.1 11/14/2005 22:30:00 13.7 1.1 16.1 11.1 13.9 1.1 16.4 10.3 5 5 6 305 -2.9 0 -2.7 -3.1 11/14/2005 22:40:00 13.4 1.1 16.4 11.1 13.6 1.1 16.4 10.7 5 4 1 305 -2.8 0 -2.7 -3.1 11/14/2005 22:50:00 14.2 0.8 16.1 11.5 14.4 1 16.8 11.5 4 4 4 305 -2.9 0 -2.7 -3.1 11/14/2005 23:00:00 14.1 1 16.4 10.7 14.2 1 16.8 11.5 4 4 8 305 -2.9 0 -2.7 -3.1 11/14/2005 23:10:00 14.6 1.1 17.2 11.5 14.7 1.2 17.9 11.8 2 3 5 305 -3 0 -2.7 -3.3 11/14/2005 23:20:00 14.4 1.1 17.2 11.8 14.5 1.1 17.6 11.8 1 4 2 305 -3 0.1 -2.9 -3.3 11/14/2005 23:30:00 14.7 1 17.2 11.8 14.8 1.1 17.6 11.5 0 4 9 305 -3.2 0 -3.1 -3.3 11/14/2005 23:40:00 14.9 1 17.2 11.8 15 1.1 17.6 11.5 0 4 4 305 -3.2 0 -2.9 -3.3 11/14/2005 23:50:00 15.4 1.3 18.3 11.8 15.5 1.3 18.7 11.1 1 4 0 305 -3.2 0.1 -2.9 -3.3 11/15/2005 00:00:00 15.6 1 17.6 12.2 15.8 1 17.9 12.6 3 4 7 305 -3.3 0 -3.1 -3.3 11/15/2005 00:10:00 15.2 1 17.2 11.8 15.3 1 17.9 11.8 3 4 355 305 -3.2 0 -3.1 -3.3 11/15/2005 00:20:00 15 1 17.2 11.8 15.1 1.1 17.6 11.1 3 3 358 305 -3.2 0.1 -2.9 -3.3 11/15/2005 00:30:00 15 1 17.6 12.6 15.1 1 17.6 12.6 8 5 359 305 -3.3 0 -3.1 -3.3 11/15/2005 00:40:00 14 1.1 16.8 11.5 14 1.2 16.8 10.7 7 5 3 305 -3.2 0 -3.1 -3.3 11/15/2005 00:50:00 14.9 1.3 18.3 11.5 15 1.5 18.7 11.1 5 5 2 305 -3.3 0 -3.1 -3.3 11/15/2005 01:00:00 14.9 1.2 18.3 10.7 14.9 1.3 17.9 11.8 6 5 5 305 -3.2 0 -3.1 -3.3 11/15/2005 01:10:00 15.3 1.5 19.1 11.1 15.3 1.6 19.1 11.5 6 6 9 305 -3.2 0 -3.1 -3.3 11/15/2005 01:20:00 15.5 1.4 19.5 12.2 15.6 1.5 18.7 11.5 7 4 9 305 -3.2 0 -3.1 -3.3 11/15/2005 01:30:00 15.8 1.3 19.1 12.2 15.9 1.5 19.5 12.6 3 4 2 305 -3.2 0 -2.9 -3.3 11/15/2005 01:40:00 16 1 18.7 13.3 16.1 1.2 18.7 12.6 2 4 1 305 -3.3 0 -3.1 -3.6 11/15/2005 01:50:00 15.6 1.2 18.3 11.8 15.7 1.2 18.3 12.2 2 5 359 305 -3.4 0 -2.9 -3.6 11/15/2005 02:00:00 15.8 1.2 19.1 13 15.9 1.4 19.5 12.2 1 4 359 305 -3.4 0 -3.3 -3.6 11/15/2005 02:10:00 15.5 1.5 18.7 11.1 15.5 1.5 19.1 11.1 1 4 3 305 -3.4 0 -3.1 -3.8 11/15/2005 02:20:00 15.9 1.1 18.3 12.2 16 1.2 18.7 12.6 359 4 2 305 -3.6 0.1 -3.3 -3.8 11/15/2005 02:30:00 15.5 0.9 17.6 12.6 15.5 1.1 17.9 11.8 358 5 351 305 -3.8 0 -3.6 -3.8 11/15/2005 02:40:00 15.2 0.9 17.2 12.6 15.4 1 17.6 12.2 357 4 353 305 -3.9 0 -3.6 -4 11/15/2005 02:50:00 15.6 1 17.9 12.6 15.9 1.2 18.3 11.5 357 3 355 305 -3.9 0 -3.8 -4 11/15/2005 03:00:00 15 1.1 17.6 11.8 15.1 1.2 17.6 11.5 1 3 359 305 -3.9 0 -3.8 -4 11/15/2005 03:10:00 15.2 1 17.6 12.2 15.2 1.1 17.6 11.5 0 4 354 305 -3.9 0 -3.8 -4 11/15/2005 03:20:00 14.9 1.3 17.2 11.5 15 1.3 17.9 11.5 358 4 359 305 -3.8 0 -3.6 -4 11/15/2005 03:30:00 15.8 1.2 18.7 11.5 15.9 1.2 18.7 12.2 2 4 355 305 -3.7 0 -3.3 -3.8 11/15/2005 03:40:00 15.9 1.3 19.5 11.8 16.1 1.4 20.2 12.2 2 5 359 305 -3.6 0 -3.3 -3.8 11/15/2005 03:50:00 16 1.2 19.1 11.5 16.2 1.3 19.5 12.2 2 4 1 305 -3.5 0 -3.3 -3.8 11/15/2005 04:00:00 16.4 1 18.7 13.7 16.6 1 19.1 13 3 5 6 305 -3.6 0 -3.1 -3.8 11/15/2005 04:10:00 16.5 1.2 19.5 13.3 16.7 1.2 19.9 13.3 1 4 2 305 -3.5 0 -3.3 -3.8 11/15/2005 04:20:00 15.9 1.2 18.7 12.6 16 1.3 19.1 12.2 1 5 355 305 -3.5 0 -3.3 -3.8 11/15/2005 04:30:00 16.2 1.3 19.5 12.2 16.4 1.3 19.5 12.6 0 4 357 305 -3.5 0 -3.3 -3.8 11/15/2005 04:40:00 16.5 1.4 19.1 12.2 16.6 1.5 19.5 12.2 1 5 3 305 -3.6 0 -3.3 -3.8 11/15/2005 04:50:00 16.7 1.3 19.1 13.7 16.7 1.3 19.5 13.3 4 4 4 305 -3.7 0.1 -3.3 -3.8 11/15/2005 05:00:00 16.8 1.2 19.5 12.2 17 1.3 20.2 13.3 6 4 9 305 -3.7 0 -3.3 -3.8 11/15/2005 05:10:00 16.9 1.2 19.1 13 17 1.2 19.5 13.7 3 4 8 305 -3.6 0 -3.3 -3.8 11/15/2005 05:20:00 16.7 1.1 19.5 13.7 16.8 1.2 19.9 13 357 4 1 305 -3.7 0 -3.3 -3.8 11/15/2005 05:30:00 16 1.4 18.7 11.8 16.1 1.5 19.5 11.1 356 4 359 305 -3.7 0.1 -3.3 -3.8 11/15/2005 05:40:00 16.3 1.2 19.1 13 16.4 1.3 18.7 12.6 357 4 359 305 -3.7 0 -3.6 -3.8 11/15/2005 05:50:00 16.6 1.3 19.1 12.2 16.8 1.3 19.5 12.6 356 4 356 305 -3.8 0 -3.6 -4 11/15/2005 06:00:00 16.9 1.5 20.6 13 17.1 1.5 21 13.7 357 4 2 305 -3.8 0 -3.6 -4 11/15/2005 06:10:00 17.3 1.1 19.9 13.7 17.4 1.3 19.9 13.3 358 4 359 305 -3.8 0 -3.6 -4 11/15/2005 06:20:00 16.7 1.2 19.1 13 16.8 1.2 20.2 13 359 4 358 305 -3.7 0 -3.3 -4 11/15/2005 06:30:00 17.4 1.3 20.6 12.6 17.7 1.3 21.4 13.7 0 4 5 305 -3.7 0 -3.6 -3.8 11/15/2005 06:40:00 17.2 1.2 19.9 13 17.2 1.3 20.6 13 1 5 357 305 -3.8 0 -3.3 -4 11/15/2005 06:50:00 17.5 1.2 19.9 13.7 17.6 1.2 20.2 13.7 358 4 355 305 -3.9 0 -3.8 -4 11/15/2005 07:00:00 17.5 1.4 20.6 13.3 17.6 1.6 20.2 13 358 4 0 305 -4 0 -3.8 -4.2 11/15/2005 07:10:00 16.6 1.4 19.9 13 16.7 1.4 19.9 12.6 0 4 352 305 -3.9 0 -3.8 -4 11/15/2005 07:20:00 16.7 1.2 19.5 13.3 16.8 1.2 19.9 13.3 0 4 359 305 -3.9 0 -3.8 -4.2 11/15/2005 07:30:00 17.1 1.2 19.9 14.5 17.2 1.2 19.9 13.7 0 4 355 305 -4.2 0.1 -4 -4.5 11/15/2005 07:40:00 16.8 1.3 19.5 12.2 17 1.5 19.5 13 2 3 2 305 -4.3 0 -4 -4.5 11/15/2005 07:50:00 17.5 1.1 19.5 13 17.7 1.2 20.2 13.7 359 3 3 305 -4.4 0 -4.2 -4.7 11/15/2005 08:00:00 16.4 1.4 19.9 12.2 16.5 1.4 19.5 12.6 1 4 1 305 -4.4 0 -4.2 -4.7 11/15/2005 08:10:00 16.7 1.2 19.5 13 16.9 1.3 19.9 12.6 357 4 2 305 -4.6 0 -4.5 -4.7 11/15/2005 08:20:00 16.9 1.2 19.9 13.7 16.9 1.2 20.2 13.3 358 4 1 305 -4.6 0.1 -4.5 -4.9 11/15/2005 08:30:00 16.7 1.3 19.9 13 16.8 1.5 20.6 13 357 6 2 305 -4.7 0 -4.5 -4.9 11/15/2005 08:40:00 17.2 1.5 20.6 12.2 17.2 1.7 20.6 12.6 358 4 356 305 -4.8 0 -4.5 -4.9 11/15/2005 08:50:00 16.6 1.4 19.5 13.3 16.7 1.5 19.9 13 358 5 355 305 -4.9 0 -4.7 -5.1 11/15/2005 09:00:00 16.6 1.5 19.5 13 16.7 1.5 19.9 12.6 357 5 357 305 -4.8 0 -4.5 -5.1 11/15/2005 09:10:00 17.3 1.3 20.2 13.7 17.4 1.5 21 13.3 357 4 354 305 -4.9 0 -4.7 -5.1 11/15/2005 09:20:00 16.9 1.3 19.5 11.8 16.9 1.5 20.6 12.6 357 5 1 305 -5 0 -4.7 -5.1 11/15/2005 09:30:00 16.8 1.5 20.2 12.2 16.8 1.6 21 12.6 358 5 353 305 -5.1 0 -4.9 -5.6 11/15/2005 09:40:00 16.8 1.4 19.5 13 16.9 1.5 19.9 13 359 5 3 305 -5.2 0.1 -4.9 -5.6 11/15/2005 09:50:00 15.8 1.3 19.5 12.2 15.9 1.4 19.9 12.6 0 4 0 305 -5.2 0.1 -4.7 -5.6 11/15/2005 10:00:00 16.3 1.5 19.1 11.5 16.3 1.7 19.9 11.5 1 4 0 305 -5.2 0.1 -4.7 -5.6 11/15/2005 10:10:00 16.9 1.2 19.1 13.3 16.9 1.4 19.5 13 1 4 358 305 -5.3 0 -5.1 -5.6 11/15/2005 10:20:00 16.5 1.2 19.5 13 16.6 1.3 19.9 12.6 1 4 4 305 -5.2 0 -5.1 -5.6 11/15/2005 10:30:00 15.7 1.3 18.7 11.8 15.8 1.4 19.1 12.2 4 5 0 305 -5.1 0 -4.9 -5.1 11/15/2005 10:40:00 16 1.2 19.1 13 16.1 1.3 19.1 12.2 4 5 4 305 -5.2 0.1 -4.9 -5.6 11/15/2005 10:50:00 16.4 1.1 19.1 11.8 16.4 1.2 18.7 12.6 3 5 9 305 -5.3 0.1 -5.1 -5.6 11/15/2005 11:00:00 15.7 1.3 18.7 11.5 15.8 1.3 19.1 11.8 1 5 359 305 -5.3 0.1 -5.1 -5.6 11/15/2005 11:10:00 15.1 1.5 18.7 11.1 15.2 1.5 18.3 12.2 3 5 0 305 -5.2 0 -4.9 -5.6 11/15/2005 11:20:00 15.5 1.3 18.7 11.5 15.6 1.3 19.1 11.5 3 5 2 305 -5.3 0.1 -5.1 -5.6 11/15/2005 11:30:00 15.6 1.2 18.3 12.2 15.8 1.3 18.7 12.2 3 4 0 305 -5.5 0 -5.1 -5.6 11/15/2005 11:40:00 14.8 1.3 17.9 11.5 15 1.4 18.3 11.1 4 5 10 305 -5.4 0 -5.1 -5.6 11/15/2005 11:50:00 15.1 1.5 18.3 10.7 15.1 1.5 18.7 10.7 7 5 8 305 -5.4 0.1 -4.9 -5.6 11/15/2005 12:00:00 15.9 1.2 18.3 11.8 16 1.3 19.1 11.8 4 5 359 305 -5.5 0 -5.1 -5.8 11/15/2005 12:10:00 16.1 1.3 18.7 12.2 16.2 1.3 18.7 12.2 4 4 7 305 -5.5 0 -5.3 -5.8 11/15/2005 12:20:00 16.5 1.2 18.7 12.6 16.5 1.2 19.1 12.6 3 3 4 305 -5.5 0 -5.3 -5.8 11/15/2005 12:30:00 16.4 1.2 19.1 13.3 16.4 1.3 19.5 13 4 4 1 305 -5.5 0 -5.3 -5.8 11/15/2005 12:40:00 17.7 1.2 20.2 14.1 17.7 1.2 20.2 14.5 5 4 9 305 -5.5 0 -5.3 -5.8 11/15/2005 12:50:00 15.6 1.1 18.3 12.2 15.7 1.2 18.7 12.2 3 5 355 305 -5.5 0 -5.1 -5.6 11/15/2005 13:00:00 15.3 1.3 18.3 11.5 15.4 1.4 18.3 11.5 0 5 0 305 -5.4 0 -5.1 -5.6 11/15/2005 13:10:00 15.6 1.2 18.3 11.5 15.7 1.3 19.1 11.8 1 4 4 305 -5.2 0 -4.9 -5.6 11/15/2005 13:20:00 16.3 1.2 18.7 12.6 16.4 1.3 19.1 12.2 358 4 351 305 -5.3 0.1 -4.9 -5.6 11/15/2005 13:30:00 17.5 1 19.9 14.5 17.5 1.2 20.2 13.3 359 3 358 305 -5.3 0 -5.1 -5.6 11/15/2005 13:40:00 17.3 1.1 19.5 13.7 17.3 1.2 19.9 13 3 4 1 305 -5.2 0 -4.9 -5.3 11/15/2005 13:50:00 16.5 1.1 19.5 13.3 16.5 1.2 19.9 13 3 4 358 305 -5 0 -4.7 -5.1 11/15/2005 14:00:00 16.7 1.5 19.9 12.2 16.7 1.5 20.2 11.8 5 5 6 305 -4.9 0 -4.7 -5.1 11/15/2005 14:10:00 17.9 1.4 21 14.1 17.8 1.5 21.4 14.1 3 4 7 305 -5 0 -4.7 -5.1 11/15/2005 14:20:00 17.9 1.5 21 14.9 17.9 1.6 21.4 14.1 5 4 5 305 -5 0.1 -4.7 -5.1 11/15/2005 14:30:00 17.6 1.3 20.6 14.1 17.6 1.5 21.4 14.1 5 4 3 305 -4.8 0 -4.7 -4.9 11/15/2005 14:40:00 18.1 1.3 20.6 13.7 18.1 1.4 21.4 13.7 3 4 0 305 -4.9 0 -4.5 -5.1 11/15/2005 14:50:00 18.3 1 20.6 15.3 18.3 1.2 21 14.9 0 4 357 305 -5 0 -4.7 -5.3 11/15/2005 15:00:00 17.4 1.2 19.9 14.1 17.5 1.2 20.6 14.1 0 4 0 305 -5.2 0.1 -4.9 -5.6 11/15/2005 15:10:00 17 1.3 19.9 13.7 17.1 1.3 19.9 13 0 4 3 305 -5.3 0 -5.1 -5.6 11/15/2005 15:20:00 17 1.5 19.9 13 17 1.5 20.2 13 358 5 356 305 -5.2 0.1 -4.9 -5.6 11/15/2005 15:30:00 17.1 1.5 20.6 12.6 17.2 1.5 20.2 13 359 4 359 305 -5.3 0 -5.1 -5.6 11/15/2005 15:40:00 18 1.3 21 14.1 18.1 1.4 21 14.1 357 4 357 305 -5.4 0 -5.1 -5.6 11/15/2005 15:50:00 17.7 1.4 21 14.1 17.8 1.5 21.4 13.7 356 5 352 305 -5.3 0 -5.1 -5.6 11/15/2005 16:00:00 17.3 1.5 20.6 13.3 17.4 1.6 21 13 357 4 355 305 -5.4 0 -5.1 -5.6 11/15/2005 16:10:00 16.8 1.3 20.6 13.7 17 1.4 21 12.6 356 5 2 305 -5.4 0 -5.1 -5.6 11/15/2005 16:20:00 17.4 1.2 21 13 17.4 1.3 21.4 13.7 358 4 354 305 -5.5 0 -5.1 -5.6 11/15/2005 16:30:00 17.4 1.4 20.6 12.6 17.5 1.5 20.6 12.2 359 4 1 305 -5.5 0 -5.1 -5.8 11/15/2005 16:40:00 16.7 1.5 19.5 13 16.7 1.5 19.5 12.2 358 4 359 305 -5.5 0 -5.3 -5.8 11/15/2005 16:50:00 16.9 1.4 19.9 13 16.9 1.4 19.5 13 359 5 355 305 -5.5 0 -5.1 -5.8 11/15/2005 17:00:00 16.7 1.4 19.9 13.3 16.8 1.5 19.9 13.3 358 4 358 305 -5.5 0 -5.1 -5.8 11/15/2005 17:10:00 16.7 1.2 19.5 13 16.8 1.3 20.2 12.2 359 5 3 305 -5.5 0 -5.1 -5.8 11/15/2005 17:20:00 17.3 1.2 19.9 14.1 17.5 1.3 20.6 14.1 358 4 355 305 -5.6 0 -5.1 -6 11/15/2005 17:30:00 17 1.3 20.2 13 17.1 1.4 20.2 13.7 0 4 0 305 -5.7 0.1 -5.6 -6 11/15/2005 17:40:00 17.3 1.2 19.9 13.7 17.3 1.2 20.2 14.5 0 5 1 305 -5.8 0.1 -5.6 -6 11/15/2005 17:50:00 17.2 1.3 20.2 13.3 17.2 1.4 21 13.3 1 4 1 305 -5.8 0 -5.6 -6 11/15/2005 18:00:00 17.8 1.3 21 14.1 17.9 1.3 21.8 14.9 0 4 2 305 -5.9 0.1 -5.6 -6 11/15/2005 18:10:00 17.7 1.4 20.6 14.5 17.7 1.5 21.4 13.3 2 5 6 305 -6 0 -5.8 -6.2 11/15/2005 18:20:00 17.1 1.6 20.6 12.2 17.3 1.7 21 12.6 359 5 358 305 -6.1 0 -5.8 -6.4 11/15/2005 18:30:00 17.1 1.2 19.9 13.7 17.1 1.3 20.6 13 1 5 0 305 -6.1 0 -6 -6.4 11/15/2005 18:40:00 17.2 1.2 20.2 14.5 17.3 1.3 20.2 13.7 2 4 0 305 -6.2 0 -5.8 -6.4 11/15/2005 18:50:00 16.9 1.4 19.5 12.2 16.9 1.4 20.2 12.2 0 4 0 305 -6.2 0 -6 -6.4 11/15/2005 19:00:00 17.5 1.5 20.2 13.3 17.5 1.5 21 13.7 1 5 3 305 -6.2 0 -5.8 -6.4 11/15/2005 19:10:00 16.9 1.2 19.5 13.3 17 1.2 20.2 13.7 2 5 6 305 -6.2 0 -5.8 -6.4 11/15/2005 19:20:00 16.5 1.5 19.9 12.6 16.5 1.5 19.9 12.6 0 5 351 305 -6.1 0 -6 -6.4 11/15/2005 19:30:00 16.8 1.3 20.2 13 16.8 1.5 21 13 1 4 1 305 -6.2 0 -6 -6.4 11/15/2005 19:40:00 16.9 1.5 19.9 13 17 1.5 20.2 13.3 0 3 3 305 -6.2 0 -6 -6.4 11/15/2005 19:50:00 17.1 1.3 19.9 12.2 17.1 1.5 19.9 13 359 4 358 305 -6.2 0 -5.8 -6.4 11/15/2005 20:00:00 16.7 1.2 19.5 13.3 16.7 1.3 19.9 13.3 359 4 355 305 -6.2 0 -6 -6.4 11/15/2005 20:10:00 16.7 1.3 19.9 13 16.6 1.3 19.5 13 0 5 4 305 -6.1 0 -5.8 -6.2 11/15/2005 20:20:00 17.3 1.2 19.9 13.3 17.4 1.3 20.2 13 359 5 356 305 -6.3 0 -6 -6.7 11/15/2005 20:30:00 17.3 1.3 20.6 13 17.4 1.3 21 13.3 3 4 4 305 -6.4 0 -6 -6.7 11/15/2005 20:40:00 16.5 1.5 19.5 11.8 16.6 1.6 19.9 11.8 4 5 2 305 -6.3 0.1 -6 -6.7 11/15/2005 20:50:00 17.4 1.4 21 13.3 17.6 1.4 21 13 0 4 5 305 -6.3 0.1 -6 -6.7 11/15/2005 21:00:00 17.4 1.4 20.6 13 17.4 1.5 20.2 13.3 1 5 2 305 -6.4 0.1 -6 -6.7 11/15/2005 21:10:00 16.9 1.5 20.2 12.6 16.9 1.6 20.6 12.6 356 4 357 305 -6.3 0.1 -6 -6.7 11/15/2005 21:20:00 17.1 1.7 20.2 12.2 17.1 1.8 21 11.8 3 4 3 305 -6.1 0 -5.8 -6.4 11/15/2005 21:30:00 17.3 1.6 20.6 11.8 17.2 1.7 21 12.6 359 4 0 305 -6.2 0 -6 -6.4 11/15/2005 21:40:00 17.2 1.5 20.2 11.8 17.3 1.6 20.6 12.2 1 5 10 305 -6.2 0 -5.8 -6.4 11/15/2005 21:50:00 17.3 1.1 19.9 13.7 17.3 1.2 19.9 13.7 2 5 359 305 -6.2 0 -6 -6.4 11/15/2005 22:00:00 17.1 1.2 19.9 14.1 17.2 1.3 19.9 13 358 5 353 305 -6.2 0 -6 -6.4 11/15/2005 22:10:00 17.6 1.3 20.6 13.7 17.7 1.3 20.6 14.1 1 6 13 305 -6.4 0 -6 -6.7 11/15/2005 22:20:00 16.8 1.3 21 13.3 16.9 1.3 21 13 1 5 357 305 -6.3 0.1 -6 -6.7 11/15/2005 22:30:00 17.1 1.3 20.2 13.3 17.2 1.4 20.2 13.7 0 5 359 305 -6.3 0 -6 -6.4 11/15/2005 22:40:00 17.3 1.5 20.6 13 17.3 1.5 21 12.6 3 6 7 305 -6.3 0 -6 -6.7 11/15/2005 22:50:00 18 1.7 21.8 13 18 1.7 22.6 13 0 4 1 305 -6.3 0 -6 -6.7 11/15/2005 23:00:00 18.1 1.3 21 13.3 18.1 1.4 21.8 14.1 1 4 3 305 -6.4 0.1 -6 -6.7 11/15/2005 23:10:00 18 1.7 21 11.8 18 1.6 21.4 13.3 0 5 358 305 -6.4 0 -6.2 -6.7 11/15/2005 23:20:00 18.3 1.5 21 13.3 18.3 1.6 21.4 13.3 359 5 0 305 -6.6 0 -6.4 -6.9 11/15/2005 23:30:00 19 1.3 22.6 14.1 19 1.5 22.6 15.3 1 5 0 305 -6.5 0 -6.2 -6.9 11/15/2005 23:40:00 18.7 1.5 22.1 13 18.7 1.6 22.1 13.7 1 4 3 305 -6.7 0 -6.2 -6.9 11/15/2005 23:50:00 17.6 1.3 21.4 14.1 17.6 1.5 22.1 13.3 2 5 3 305 -6.5 0 -6.2 -6.9 11/16/2005 00:00:00 17.6 1.5 21 13.7 17.7 1.5 21.4 12.6 0 5 1 305 -6.3 0.2 -6 -6.7 11/16/2005 00:10:00 17.6 1.5 21 13.3 17.6 1.5 21 13.3 2 5 4 305 -6.4 0.1 -6 -6.7 11/16/2005 00:20:00 17.7 1.2 20.2 12.6 17.7 1.3 21 13.7 1 5 0 305 -6.3 0 -6 -6.7 11/16/2005 00:30:00 18.5 1.3 21.8 14.9 18.5 1.4 22.6 15.3 2 5 2 305 -6.3 0.1 -6 -6.7 11/16/2005 00:40:00 17.8 1.3 21.8 14.1 17.9 1.5 21 14.1 1 4 7 305 -6.4 0 -6.2 -6.7 11/16/2005 00:50:00 18.1 1.2 20.6 14.1 18.2 1.3 20.6 14.1 4 4 10 305 -6.2 0 -6 -6.4 11/16/2005 01:00:00 18.3 1.1 21 14.9 18.4 1.2 21.8 14.9 359 5 1 305 -6.3 0 -6 -6.7 11/16/2005 01:10:00 18.2 1.8 21.4 12.6 18.2 1.8 21.8 13.3 0 4 355 305 -6.2 0 -6 -6.4 11/16/2005 01:20:00 17.3 1.3 20.2 13.3 17.3 1.5 21.4 13.3 1 5 5 305 -6.1 0.1 -5.8 -6.4 11/16/2005 01:30:00 18 1.5 20.6 13.3 17.9 1.5 21 13 2 5 357 305 -6.1 0 -5.8 -6.2 11/16/2005 01:40:00 17.6 1.5 20.6 13.3 17.6 1.7 21 13.7 1 5 359 305 -6.2 0 -6 -6.4 11/16/2005 01:50:00 17.8 1.5 21 13.7 17.7 1.7 21.4 13.7 1 5 5 305 -6.1 0 -5.8 -6.4 11/16/2005 02:00:00 17.4 1.2 20.2 14.1 17.5 1.2 19.9 14.5 1 4 0 305 -6.2 0 -6 -6.4 11/16/2005 02:10:00 18.4 1.7 21.8 13.7 18.5 1.9 22.1 13.7 0 4 0 305 -6.1 0 -5.8 -6.4 11/16/2005 02:20:00 18.6 1.8 21.4 12.2 18.6 1.8 22.1 13 1 4 355 305 -6.2 0 -6 -6.4 11/16/2005 02:30:00 17.8 1.7 22.6 13.7 17.9 1.7 22.6 13.7 359 5 7 305 -6.3 0 -6 -6.7 11/16/2005 02:40:00 17.5 1.4 20.6 13 17.4 1.6 21 13 1 5 7 305 -6.3 0 -6 -6.7 11/16/2005 02:50:00 17.7 1.4 21 13.7 17.8 1.3 21.4 13.7 1 5 357 305 -6.4 0.1 -6 -6.7 11/16/2005 03:00:00 17.3 1.3 19.9 13.3 17.3 1.4 19.9 12.6 2 5 3 305 -6.4 0.1 -6 -6.7 11/16/2005 03:10:00 17.7 1.4 21.4 14.1 17.7 1.5 21.8 13.7 1 5 357 305 -6.4 0.1 -6 -6.7 11/16/2005 03:20:00 17.9 1.3 21.8 13.3 18 1.3 21.4 14.1 1 5 6 305 -6.2 0 -6 -6.4 11/16/2005 03:30:00 18.2 1.3 21.4 14.1 18.4 1.3 21.4 14.5 1 5 1 305 -6.3 0 -6 -6.4 11/16/2005 03:40:00 18.3 1.5 21.4 13.7 18.3 1.6 21.8 13.3 2 4 0 305 -6.1 0 -5.8 -6.2 11/16/2005 03:50:00 18.5 1.8 22.6 12.6 18.5 1.8 21.8 13 0 5 359 305 -6.2 0.1 -5.8 -6.7 11/16/2005 04:00:00 18.1 1.6 21.8 13.7 18.2 1.6 21.8 14.1 3 5 6 305 -6.3 0 -6 -6.7 11/16/2005 04:10:00 19.6 1.6 22.9 15.3 19.6 1.7 23.3 14.5 2 5 356 305 -6.2 0 -5.8 -6.4 11/16/2005 04:20:00 18.7 1.7 21.8 14.1 18.6 1.8 22.6 13.7 6 4 6 305 -6 0 -5.8 -6.2 11/16/2005 04:30:00 18.5 1.7 22.6 13.3 18.5 1.7 22.1 11.5 2 5 0 305 -6.1 0.2 -5.8 -6.7 11/16/2005 04:40:00 18.6 1.5 22.1 14.9 18.7 1.5 22.1 14.5 359 5 359 305 -6.4 0.1 -6 -6.7 11/16/2005 04:50:00 18.7 1.7 22.1 13 18.7 1.7 22.6 13.3 358 5 357 305 -6.3 0.1 -6 -6.7 11/16/2005 05:00:00 19.2 1.5 22.6 14.5 19.1 1.5 22.9 14.9 0 4 2 305 -6.1 0 -5.8 -6.4 11/16/2005 05:10:00 19.4 1.5 23.3 15.6 19.5 1.5 22.9 15.6 3 5 1 305 -6.2 0 -6 -6.7 11/16/2005 05:20:00 18.7 1.7 21.8 14.1 18.6 1.8 22.1 14.1 1 5 4 305 -6.2 0.1 -6 -6.4 11/16/2005 05:30:00 19 1.5 22.1 14.1 19.1 1.6 22.6 14.1 0 4 358 305 -6.3 0 -6 -6.7 11/16/2005 05:40:00 18.9 1.2 21.8 15.3 18.9 1.4 21.8 14.5 0 4 2 305 -6.2 0 -6 -6.4 11/16/2005 05:50:00 18.7 1.5 21.4 13.7 18.7 1.6 21.8 13.3 1 5 353 305 -6.2 0 -6 -6.4 11/16/2005 06:00:00 18.6 1.4 21.4 14.9 18.7 1.5 21.8 13.7 1 5 355 305 -6.2 0.1 -6 -6.4 11/16/2005 06:10:00 18.4 1.7 22.1 14.1 18.3 1.8 22.9 14.1 0 5 354 305 -6.3 0.1 -6 -6.7 11/16/2005 06:20:00 18.5 1.6 21.8 13.7 18.5 1.7 22.1 13.3 359 5 5 305 -6.2 0 -6 -6.4 11/16/2005 06:30:00 17.9 1.5 21 13.7 17.8 1.5 21.4 13.3 2 5 357 305 -6.4 0 -6.2 -6.7 11/16/2005 06:40:00 18.8 1.7 22.9 13.3 18.8 1.8 23.7 14.1 2 5 3 305 -6.1 0 -6 -6.4 11/16/2005 06:50:00 19.3 1.5 23.3 15.3 19.3 1.6 23.3 14.1 3 4 5 305 -6 0 -5.8 -6.2 11/16/2005 07:00:00 18.4 1.5 22.9 14.1 18.3 1.6 22.1 14.5 359 4 5 305 -6.2 0 -6 -6.4 11/16/2005 07:10:00 18.4 1.3 21.4 14.9 18.5 1.4 21.4 14.5 359 4 356 305 -6.2 0 -6 -6.4 11/16/2005 07:20:00 18 1.7 21 11.8 18 1.7 21.4 12.2 0 4 358 305 -6.2 0.1 -5.8 -6.7 11/16/2005 07:30:00 17.9 1.6 21.4 13 17.8 1.6 21.4 13 1 5 7 305 -6.3 0.1 -5.8 -6.7 11/16/2005 07:40:00 17.5 1.7 21.8 13 17.4 1.8 21.8 13 0 4 1 305 -6.2 0 -5.8 -6.4 11/16/2005 07:50:00 18.5 1.3 21.4 13.7 18.4 1.4 21.8 13.7 1 5 359 305 -6.2 0 -5.8 -6.4 11/16/2005 08:00:00 17.9 1.5 21.8 14.5 17.8 1.5 22.1 14.1 5 5 11 305 -6.2 0.1 -5.8 -6.7 11/16/2005 08:10:00 18.6 1.4 22.1 14.5 18.5 1.5 22.6 13.3 0 4 359 305 -6.4 0.1 -5.8 -6.7 11/16/2005 08:20:00 18.2 1.7 21.8 13.3 18.1 1.5 21.8 14.1 0 4 358 305 -6.3 0 -6 -6.7 11/16/2005 08:30:00 18.3 1.3 21.4 13.3 18.3 1.3 22.1 13.7 357 4 353 305 -6.4 0 -6 -6.7 11/16/2005 08:40:00 18.2 1.3 21 14.1 18 1.4 21.8 14.1 359 5 357 305 -6.3 0.1 -6 -6.7 11/16/2005 08:50:00 18.5 1.7 22.1 13.7 18.2 1.7 21.8 13 359 5 0 305 -6.2 0 -5.8 -6.4 11/16/2005 09:00:00 17.6 2 21.4 12.6 17.3 2 21 11.5 3 5 0 305 -6.2 0.1 -5.8 -6.4 11/16/2005 09:10:00 18.8 1.7 22.6 13.3 18.4 1.7 21.8 13 6 5 1 305 -6 0 -5.6 -6.2 11/16/2005 09:20:00 18 1.6 20.6 12.6 17.7 1.6 20.6 12.2 5 5 8 305 -6.2 0 -5.8 -6.4 11/16/2005 09:30:00 18.1 1.2 20.2 14.1 17.8 1.3 20.2 14.1 4 4 0 305 -6 0 -5.6 -6.2 11/16/2005 09:40:00 17.8 1.4 21.8 14.1 17.5 1.3 21.4 13 15 8 21 305 -6 0 -5.8 -6.2 11/16/2005 09:50:00 18 2.1 22.1 13.3 17.5 2.1 22.1 12.2 16 5 20 305 -5.7 0.1 -5.6 -6 11/16/2005 10:00:00 17.3 1.6 20.6 13.3 16.9 1.7 20.6 11.8 15 6 11 305 -5.5 0 -5.1 -5.8 11/16/2005 10:10:00 18.8 1.5 22.6 14.1 18.5 1.5 22.6 14.1 12 5 8 305 -5.7 0 -5.6 -5.8 11/16/2005 10:20:00 18.5 1.7 22.6 13.7 18 1.7 22.6 13 12 4 18 305 -5.6 0.1 -5.3 -6 11/16/2005 10:30:00 16.4 1.3 19.5 12.2 16.1 1.3 19.9 12.2 17 6 32 305 -5.5 0 -5.3 -5.6 11/16/2005 10:40:00 17.8 1.6 21.4 13 17.5 1.8 21 13 11 5 13 305 -5.6 0 -5.3 -5.8 11/16/2005 10:50:00 17 2.1 22.1 12.2 16.5 2.1 21.4 12.2 17 6 11 305 -5.7 0 -5.6 -6 11/16/2005 11:00:00 17.9 1.8 21.8 13.3 17.4 1.8 21.4 13.3 26 6 17 305 -5.6 0.2 -5.1 -5.8 11/16/2005 11:10:00 16.9 1.3 19.9 13.3 16.7 1.3 19.5 13.3 22 5 29 305 -5.5 0 -5.1 -5.8 11/16/2005 11:20:00 17.5 1.3 20.2 13.3 17.1 1.3 19.9 13.3 17 4 17 305 -5.6 0.1 -5.1 -5.8 11/16/2005 11:30:00 17.1 1.7 21 13.3 16.8 1.7 20.6 12.6 19 4 24 305 -5.6 0 -5.1 -5.8 11/16/2005 11:40:00 17 1.3 20.2 12.2 16.8 1.4 19.9 13 21 5 23 305 -5.5 0.1 -5.1 -5.8 11/16/2005 11:50:00 17.4 1.4 21.4 13.7 17 1.5 21.4 13.3 21 5 22 305 -5.5 0.2 -5.1 -6 11/16/2005 12:00:00 16.6 1.2 20.6 12.6 16.4 1.2 19.5 13 20 6 21 305 -5.5 0.1 -5.1 -5.8 11/16/2005 12:10:00 17 1.6 20.2 11.5 16.6 1.7 20.2 11.8 26 5 31 305 -5.3 0.1 -4.9 -5.8 11/16/2005 12:20:00 15.9 1.5 19.5 12.2 15.7 1.5 19.5 12.2 25 5 24 305 -5 0 -4.7 -5.3 11/16/2005 12:30:00 17.2 1.5 20.6 13.3 16.9 1.5 21 13.3 25 5 24 305 -5 0 -4.7 -5.1 11/16/2005 12:40:00 16.1 1.3 19.9 11.8 15.9 1.3 19.1 12.2 20 6 19 305 -5.3 0.1 -4.9 -5.6 11/16/2005 12:50:00 17.5 2.5 22.9 11.8 17.2 2.4 22.9 12.2 26 5 29 305 -5.2 0.1 -4.7 -5.6 11/16/2005 13:00:00 16.8 1.3 19.9 13 16.6 1.3 19.9 13.3 27 6 22 305 -5 0.1 -4.7 -5.1 11/16/2005 13:10:00 16.4 1.5 20.2 13 16.1 1.6 20.2 12.6 27 5 29 305 -4.9 0 -4.7 -5.1 11/16/2005 13:20:00 16.9 1.6 20.6 13 16.7 1.7 20.2 13 24 5 26 305 -4.9 0.1 -4.5 -5.1 11/16/2005 13:30:00 18.3 1.5 21 14.1 18.2 1.5 21.8 13.3 23 5 18 305 -4.7 0 -4.5 -4.9 11/16/2005 13:40:00 18.5 1.5 22.6 15.3 18.3 1.5 22.9 14.5 25 5 25 305 -4.7 0.1 -4.5 -4.9 11/16/2005 13:50:00 18 1.6 21.4 14.1 17.9 1.7 21.8 14.1 26 5 19 305 -4.9 0 -4.5 -5.1 11/16/2005 14:00:00 18.2 1.3 21 14.5 17.9 1.3 21 14.1 28 5 26 305 -4.9 0 -4.5 -5.1 11/16/2005 14:10:00 17.8 1.7 21.8 13.3 17.6 1.7 21.8 14.1 27 5 32 305 -4.9 0 -4.7 -4.9 11/16/2005 14:20:00 16.7 1.4 19.9 12.6 16.6 1.5 19.9 13 22 8 12 305 -4.7 0 -4.5 -4.9 11/16/2005 14:30:00 17.5 1.5 20.6 13 17.5 1.7 21 13 21 6 23 305 -4.8 0 -4.7 -5.1 11/16/2005 14:40:00 17.4 1.6 21.4 12.6 17.2 1.7 21.8 13 22 5 23 305 -4.9 0 -4.7 -5.3 11/16/2005 14:50:00 17.9 1.5 21 13.3 17.8 1.6 21.8 13.7 19 5 15 305 -4.9 0 -4.7 -5.1 11/16/2005 15:00:00 16.9 1.5 20.6 13.3 16.8 1.6 20.2 13 20 5 20 305 -4.9 0.1 -4.7 -5.1 11/16/2005 15:10:00 17.5 1.3 20.6 13.7 17.4 1.3 20.6 14.1 24 4 18 305 -5 0 -4.7 -5.1 11/16/2005 15:20:00 17.2 1.4 20.6 12.6 17.1 1.5 20.2 13 19 7 24 305 -4.8 0 -4.5 -4.9 11/16/2005 15:30:00 15.7 1.3 19.5 12.2 15.6 1.3 19.1 11.8 20 8 16 305 -4.9 0 -4.7 -4.9 11/16/2005 15:40:00 16.7 1.4 19.9 13 16.7 1.4 19.5 12.6 16 8 24 305 -5 0.2 -4.5 -5.3 11/16/2005 15:50:00 16.3 1.6 19.9 12.2 16.2 1.7 21 12.2 18 6 14 305 -4.8 0.1 -4.5 -5.1 11/16/2005 16:00:00 16.4 1.5 20.2 13.3 16.3 1.5 20.2 12.6 18 5 23 305 -5 0 -4.7 -5.1 11/16/2005 16:10:00 16.6 1.4 19.9 12.2 16.4 1.4 19.5 12.2 17 8 18 305 -4.7 0.1 -4.5 -4.9 11/16/2005 16:20:00 16.6 1.8 19.9 13 16.5 1.9 19.9 12.6 16 6 12 305 -5.3 0.2 -4.7 -5.8 11/16/2005 16:30:00 17 1.6 20.2 13 16.9 1.6 20.2 12.6 14 6 6 305 -5.2 0.1 -4.9 -5.6 11/16/2005 16:40:00 17.2 1.5 20.6 13.3 17.1 1.5 20.2 13.3 19 6 11 305 -5.5 0 -5.1 -5.8 11/16/2005 16:50:00 16.6 1.5 19.9 12.2 16.5 1.5 19.9 12.6 21 5 17 305 -5.3 0.1 -4.9 -5.6 11/16/2005 17:00:00 16.7 1.3 19.5 12.6 16.6 1.5 20.2 11.8 16 5 22 305 -5.2 0.2 -4.7 -5.6 11/16/2005 17:10:00 17.7 1.5 22.6 13.3 17.5 1.7 22.6 13.3 15 5 18 305 -5.2 0 -4.9 -5.6 11/16/2005 17:20:00 17.7 1.5 21.4 13.3 17.6 1.5 21 13.7 15 4 17 305 -5 0 -4.7 -5.1 11/16/2005 17:30:00 18 1.7 21.4 13.3 17.9 1.8 22.1 13.3 15 4 10 305 -5.2 0.2 -4.7 -5.6 11/16/2005 17:40:00 16.9 1.2 21 14.1 16.9 1.2 21.4 13.7 18 5 19 305 -5.5 0.1 -4.9 -5.8 11/16/2005 17:50:00 17 1.2 20.2 13.7 16.9 1.3 20.2 13.7 16 5 20 305 -5.2 0.2 -4.7 -5.6 11/16/2005 18:00:00 16.3 1.2 18.3 12.2 16.1 1.2 19.1 11.8 17 7 13 305 -5 0 -4.5 -5.1 11/16/2005 18:10:00 16.7 1.7 20.2 13 16.7 1.7 19.9 12.2 14 4 13 305 -5.1 0 -4.7 -5.3 11/16/2005 18:20:00 16.5 1.4 19.9 12.6 16.3 1.5 19.5 12.2 16 5 20 305 -5 0 -4.5 -5.1 11/16/2005 18:30:00 16.5 1.4 19.9 12.6 16.5 1.4 19.9 12.2 13 5 18 305 -5 0 -4.7 -5.1 11/16/2005 18:40:00 16.5 1.1 19.5 13.3 16.5 1.2 19.5 13.3 12 4 15 305 -4.9 0 -4.7 -5.1 11/16/2005 18:50:00 17.3 1.3 21 13.3 17.2 1.5 21 13 11 5 16 305 -4.9 0 -4.7 -5.1 11/16/2005 19:00:00 17.7 1.2 20.6 14.5 17.6 1.3 20.6 14.5 13 4 14 305 -4.9 0.1 -4.7 -5.1 11/16/2005 19:10:00 16.8 1.3 19.5 13 16.8 1.4 19.9 13.3 18 6 17 305 -5.1 0.2 -4.7 -5.6 11/16/2005 19:20:00 16 1.2 18.7 12.6 15.9 1.3 18.7 12.2 20 4 20 305 -5.2 0.1 -4.9 -5.6 11/16/2005 19:30:00 16.3 1.7 19.9 11.8 16.2 1.9 19.9 12.2 15 6 15 305 -5 0.1 -4.7 -5.6 11/16/2005 19:40:00 15.2 1.2 17.9 12.2 15.3 1.2 17.9 11.8 13 4 14 305 -5.3 0 -4.9 -5.6 11/16/2005 19:50:00 15.9 1.7 19.9 11.8 15.9 1.7 19.9 11.8 15 5 13 305 -5.3 0.2 -4.9 -5.8 11/16/2005 20:00:00 16.9 1.5 19.9 13 16.9 1.6 20.2 12.6 9 3 9 305 -5.1 0.1 -4.7 -5.3 11/16/2005 20:10:00 16.3 1.5 20.2 13 16.3 1.5 19.9 12.6 10 5 9 305 -4.9 0 -4.7 -5.1 11/16/2005 20:20:00 16.5 1.3 19.9 12.2 16.5 1.4 20.6 12.6 14 6 13 305 -4.9 0 -4.7 -5.1 11/16/2005 20:30:00 15.8 1.3 18.7 12.2 15.9 1.4 19.5 11.8 15 4 10 305 -4.9 0 -4.7 -5.1 11/16/2005 20:40:00 15.8 1.5 19.1 11.5 15.7 1.5 18.7 11.8 13 5 10 305 -4.9 0.1 -4.5 -5.3 11/16/2005 20:50:00 15.6 1.5 18.7 12.6 15.7 1.5 18.3 11.5 13 5 13 305 -5 0.1 -4.7 -5.6 11/16/2005 21:00:00 15.8 1 17.9 12.2 15.7 1.1 18.3 12.2 13 5 11 305 -5 0.1 -4.7 -5.3 11/16/2005 21:10:00 16.6 1.3 19.5 12.6 16.6 1.3 19.9 12.6 15 5 19 305 -4.9 0.1 -4.5 -5.3 11/16/2005 21:20:00 16.4 1.3 18.7 13 16.3 1.3 19.1 11.8 8 4 8 305 -5.2 0.1 -4.7 -5.6 11/16/2005 21:30:00 16 1.2 19.9 11.5 16 1.3 19.1 11.5 9 6 10 305 -5.1 0 -4.7 -5.3 11/16/2005 21:40:00 16.4 1.2 20.2 13 16.5 1.3 19.9 12.2 6 4 8 305 -5 0 -4.7 -5.3 11/16/2005 21:50:00 16 1.6 20.6 12.2 16.1 1.6 20.6 12.6 6 5 9 305 -4.9 0 -4.7 -5.1 11/16/2005 22:00:00 16.1 1.3 19.1 11.5 16.2 1.4 19.5 11.8 3 8 358 305 -5 0 -4.7 -5.3 11/16/2005 22:10:00 15.5 1.5 18.7 12.2 15.7 1.5 19.1 11.8 10 6 7 305 -4.9 0 -4.5 -5.1 11/16/2005 22:20:00 15.5 1.4 19.9 12.2 15.5 1.3 19.1 11.8 13 6 15 305 -4.9 0.1 -4.5 -5.1 11/16/2005 22:30:00 15.7 1.3 19.1 12.2 15.7 1.4 19.5 12.2 14 5 10 305 -5 0.3 -4.5 -5.6 11/16/2005 22:40:00 14.4 1.1 17.2 11.1 14.3 1.1 16.8 11.8 19 6 14 305 -5 0.1 -4.5 -5.3 11/16/2005 22:50:00 14.6 1.2 17.6 11.5 14.7 1.2 17.6 11.5 13 5 6 305 -4.9 0.1 -4.5 -5.3 11/16/2005 23:00:00 14.9 1.2 17.6 11.5 14.9 1.3 17.9 11.8 12 6 11 305 -5 0.1 -4.7 -5.3 11/16/2005 23:10:00 15.4 1.1 18.7 11.8 15.5 1.2 18.3 12.2 1 5 0 305 -5 0 -4.7 -5.3 11/16/2005 23:20:00 16.1 1.2 18.7 13.3 16.1 1.3 18.7 13 359 5 3 305 -5.3 0 -5.1 -5.6 11/16/2005 23:30:00 15.2 1.1 17.6 11.8 15.3 1.1 17.9 11.8 4 5 5 305 -5.2 0 -4.9 -5.6 11/16/2005 23:40:00 15.1 1.3 17.9 11.5 15.1 1.3 18.3 12.2 5 5 8 305 -5 0.1 -4.7 -5.3 11/16/2005 23:50:00 15.9 1.4 18.3 11.8 16 1.5 19.1 11.5 5 7 5 305 -5 0 -4.7 -5.1 11/17/2005 00:00:00 16.2 1.2 18.7 12.6 16.2 1.3 19.5 12.2 6 5 6 305 -5 0 -4.9 -5.1 11/17/2005 00:10:00 16 1.4 19.9 12.2 16 1.5 19.9 11.5 7 5 5 305 -5 0 -4.7 -5.1 11/17/2005 00:20:00 15.4 1 17.6 12.2 15.5 1.1 17.9 11.8 9 5 6 305 -5.1 0 -4.9 -5.3 11/17/2005 00:30:00 14 1.3 17.6 10.7 14.1 1.3 17.6 10.3 10 5 11 305 -5 0 -4.9 -5.3 11/17/2005 00:40:00 15.3 1.4 18.7 11.5 15.4 1.3 18.7 11.8 8 5 5 305 -5.1 0 -4.9 -5.3 11/17/2005 00:50:00 15 1.2 17.9 11.5 15.1 1.3 18.3 11.8 8 5 13 305 -5.2 0 -5.1 -5.6 11/17/2005 01:00:00 14.9 1.2 17.2 11.1 15 1.2 17.6 10.7 6 5 3 305 -5.1 0 -4.9 -5.3 11/17/2005 01:10:00 14.2 0.9 16.1 11.5 14.2 0.9 16.4 11.8 8 5 7 305 -5.2 0 -5.1 -5.6 11/17/2005 01:20:00 14.5 1.2 17.2 11.5 14.6 1.3 17.6 11.5 4 7 8 305 -5.2 0.1 -5.1 -5.6 11/17/2005 01:30:00 14.6 1.3 17.9 11.8 14.6 1.4 17.9 10.7 6 6 7 305 -5.2 0.1 -4.7 -5.6 11/17/2005 01:40:00 14.7 1.2 17.6 11.8 14.8 1.3 17.9 11.1 359 6 350 305 -5.2 0.1 -4.9 -5.6 11/17/2005 01:50:00 14.2 1 16.4 11.5 14.3 1 16.4 11.8 358 5 4 305 -5.5 0 -5.1 -5.6 11/17/2005 02:00:00 15.5 1.2 17.9 11.8 15.7 1.3 18.7 12.2 353 5 354 305 -5.6 0 -5.3 -5.8 11/17/2005 02:10:00 14.5 1.2 17.2 11.5 14.8 1.2 17.6 11.5 353 6 352 305 -5.7 0.1 -5.6 -6 11/17/2005 02:20:00 15.4 1.2 18.3 12.2 15.7 1.3 18.7 12.2 354 4 351 305 -5.7 0 -5.6 -6 11/17/2005 02:30:00 15.4 1.4 18.7 11.1 15.5 1.5 19.1 11.5 357 6 0 305 -5.6 0 -5.6 -5.8 11/17/2005 02:40:00 15 0.9 17.2 12.2 15.2 1 17.6 12.6 356 5 358 305 -5.7 0 -5.6 -5.8 11/17/2005 02:50:00 15.4 1 17.9 12.6 15.6 1.1 17.9 13 357 4 355 305 -5.6 0 -5.6 -5.8 11/17/2005 03:00:00 15.3 1.3 18.3 11.8 15.5 1.4 18.7 11.5 356 4 2 305 -5.6 0.1 -5.3 -6 11/17/2005 03:10:00 15.2 1 18.3 12.2 15.4 1.1 18.7 12.2 356 5 350 305 -5.8 0.1 -5.6 -6 11/17/2005 03:20:00 14.9 1.1 17.6 11.8 15.1 1.2 17.9 12.2 352 4 353 305 -5.9 0.1 -5.6 -6 11/17/2005 03:30:00 15.4 1.3 17.9 11.8 15.5 1.4 18.7 11.8 350 5 342 305 -5.9 0.1 -5.6 -6 11/17/2005 03:40:00 15.5 1.5 18.7 11.1 15.6 1.5 19.1 11.1 353 4 352 305 -6 0 -5.6 -6.2 11/17/2005 03:50:00 15.7 1.4 18.7 12.2 15.9 1.5 19.1 12.2 353 5 344 305 -6.2 0 -6 -6.4 11/17/2005 04:00:00 15.7 1.8 19.5 10.7 15.8 1.8 19.5 10.7 354 4 356 305 -6.1 0 -5.8 -6.4 11/17/2005 04:10:00 15.5 1.1 17.6 11.8 15.7 1.2 17.6 11.8 355 3 348 305 -6.1 0 -5.8 -6.2 11/17/2005 04:20:00 15.3 1 17.6 12.6 15.5 1.1 18.3 12.2 352 4 356 305 -6.1 0 -5.8 -6.2 11/17/2005 04:30:00 15 1.1 17.9 12.2 15.1 1.1 18.3 11.5 355 5 353 305 -6 0 -5.8 -6.2 11/17/2005 04:40:00 15.1 1.1 17.6 11.5 15.3 1.1 17.9 11.5 355 4 355 305 -6 0 -5.8 -6.2 11/17/2005 04:50:00 14.7 1.1 17.6 11.8 14.9 1.1 17.9 11.8 357 5 357 305 -6 0 -5.6 -6.2 11/17/2005 05:00:00 15.2 1.1 18.3 12.6 15.5 1.2 18.7 12.2 356 5 359 305 -6 0 -5.8 -6.2 11/17/2005 05:10:00 15.1 1.1 18.3 12.2 15.2 1.2 18.7 12.6 351 4 351 305 -6 0 -5.8 -6.2 11/17/2005 05:20:00 15.1 1 17.2 11.5 15.3 1.1 17.6 11.8 353 4 356 305 -6 0 -5.8 -6.2 11/17/2005 05:30:00 15 1.2 17.2 11.5 15.1 1.3 17.9 11.5 356 4 354 305 -6 0 -5.6 -6.2 11/17/2005 05:40:00 15.2 1 17.6 12.6 15.5 1 17.9 12.6 356 4 356 305 -6.1 0 -5.6 -6.4 11/17/2005 05:50:00 15 1 17.2 11.8 15.2 1 17.9 11.8 357 5 357 305 -6.2 0 -6 -6.4 11/17/2005 06:00:00 15.1 1.1 17.2 11.8 15.3 1.2 17.6 12.2 357 5 351 305 -6.3 0 -6 -6.4 11/17/2005 06:10:00 14.7 1.2 17.2 10.3 14.9 1.3 17.9 9.5 2 4 0 305 -6.2 0 -6 -6.4 11/17/2005 06:20:00 14.7 0.9 16.8 11.8 14.9 1 16.8 12.2 357 5 355 305 -6.3 0 -6 -6.4 11/17/2005 06:30:00 14.9 1.2 17.6 11.8 15.1 1.2 17.6 11.8 358 5 2 305 -6.4 0 -6.2 -6.7 11/17/2005 06:40:00 14.9 1.2 17.2 11.8 15.1 1.3 17.9 12.2 359 5 2 305 -6.3 0 -6 -6.7 11/17/2005 06:50:00 15.1 1.2 18.3 11.5 15.3 1.2 17.6 11.5 357 5 353 305 -6.3 0 -6 -6.7 11/17/2005 07:00:00 14.4 1.1 18.3 11.5 14.5 1.1 16.8 11.8 356 5 5 305 -6.3 0.1 -6 -6.7 11/17/2005 07:10:00 15.1 1.3 18.3 11.5 15.2 1.3 18.3 11.8 356 5 350 305 -6.4 0 -6.2 -6.7 11/17/2005 07:20:00 14.5 1 17.2 11.8 14.6 1.1 17.2 11.8 358 5 355 305 -6.2 0 -6 -6.4 11/17/2005 07:30:00 14.7 1.1 17.2 11.8 14.9 1.1 17.6 11.1 358 4 356 305 -6.2 0 -6 -6.4 11/17/2005 07:40:00 14.8 1 17.6 12.2 14.9 1 17.6 11.8 359 5 4 305 -6.3 0 -6 -6.7 11/17/2005 07:50:00 14.4 0.9 16.4 11.5 14.5 0.9 17.2 12.2 0 5 1 305 -6.4 0.1 -6.2 -6.7 11/17/2005 08:00:00 14.3 0.9 16.4 12.2 14.6 1 16.8 12.2 358 5 348 305 -6.5 0 -6.2 -6.7 11/17/2005 08:10:00 14.3 1.1 16.8 11.5 14.5 1.2 17.6 11.8 356 5 359 305 -6.5 0 -6.2 -6.7 11/17/2005 08:20:00 13.2 1.1 15.6 9.5 13.4 1.2 16.1 9.1 358 7 355 305 -6.4 0 -6.2 -6.7 11/17/2005 08:30:00 14.1 1.1 17.2 11.5 14.4 1.1 17.2 11.8 358 5 357 305 -6.5 0 -6.2 -6.7 11/17/2005 08:40:00 13.7 0.9 15.6 11.1 14 0.9 16.1 11.5 0 5 359 305 -6.5 0.1 -6.2 -6.7 11/17/2005 08:50:00 14.3 1 17.2 11.1 14.6 1.1 17.2 10.7 358 4 2 305 -6.5 0 -6.2 -6.7 11/17/2005 09:00:00 14.7 1.1 17.2 11.8 14.9 1.2 17.6 12.2 355 4 353 305 -6.5 0.1 -6 -6.9 11/17/2005 09:10:00 14.7 1 16.8 12.2 14.9 1.1 17.6 11.8 354 4 350 305 -6.6 0 -6.4 -6.9 11/17/2005 09:20:00 14.7 1 17.2 11.1 14.9 1.1 18.3 11.8 356 4 347 305 -6.5 0 -6.2 -6.9 11/17/2005 09:30:00 14.3 1 16.4 11.5 14.5 1.1 17.2 11.5 354 4 354 305 -6.7 0 -6.4 -6.9 11/17/2005 09:40:00 14.1 1.1 16.4 11.5 14.4 1.2 16.8 11.5 352 5 343 305 -6.8 0 -6.7 -6.9 11/17/2005 09:50:00 14.3 0.9 16.1 11.5 14.5 1 16.8 11.8 354 5 354 305 -6.9 0 -6.7 -7.1 11/17/2005 10:00:00 13.8 1.2 16.4 11.1 14.1 1.2 16.4 11.1 354 5 353 305 -6.8 0 -6.7 -7.1 11/17/2005 10:10:00 14.5 1.1 17.2 10.7 14.7 1.2 17.6 10.3 355 5 353 305 -6.8 0 -6.7 -7.1 11/17/2005 10:20:00 14.3 1 16.4 10.7 14.5 1.1 16.8 11.1 355 5 357 305 -6.7 0 -6.7 -6.9 11/17/2005 10:30:00 13.5 1 15.6 10.7 13.7 1 16.1 11.1 0 5 4 305 -6.7 0 -6.4 -6.9 11/17/2005 10:40:00 13.7 1 15.6 11.1 13.9 1.1 16.4 11.5 356 5 349 305 -6.8 0 -6.7 -7.1 11/17/2005 10:50:00 13.1 1.2 15.6 9.9 13.4 1.3 16.1 10.3 356 5 352 305 -6.8 0 -6.4 -7.1 11/17/2005 11:00:00 12.9 1 15.3 10.3 13.2 1 15.6 10.7 357 6 0 305 -6.8 0.1 -6.7 -7.1 11/17/2005 11:10:00 13.3 1 15.6 10.7 13.5 1 16.1 10.3 357 4 353 305 -7 0 -6.7 -7.1 11/17/2005 11:20:00 13 1.1 15.6 9.9 13.4 1.2 16.8 9.5 359 5 354 305 -7 0.1 -6.7 -7.1 11/17/2005 11:30:00 13.4 1.1 16.4 10.7 13.7 1.2 17.2 11.1 357 6 5 305 -6.9 0 -6.7 -7.3 11/17/2005 11:40:00 14.3 0.9 16.8 11.8 14.5 0.9 16.8 11.8 354 4 351 305 -7.1 0 -6.7 -7.3 11/17/2005 11:50:00 14.2 1 16.1 11.5 14.4 1 16.8 11.1 356 5 358 305 -7.2 0 -6.9 -7.3 11/17/2005 12:00:00 14.1 0.9 16.1 11.5 14.3 1 16.4 11.1 357 5 0 305 -7.2 0 -7.1 -7.5 11/17/2005 12:10:00 14.5 0.9 16.8 11.5 14.8 1 17.6 11.1 354 3 356 305 -7.3 0 -7.1 -7.5 11/17/2005 12:20:00 14 0.9 15.6 11.1 14.3 1 16.4 11.5 359 5 356 305 -7.2 0 -6.9 -7.5 11/17/2005 12:30:00 14 1 16.1 11.1 14.2 1.1 16.4 10.7 357 5 352 305 -7.4 0 -7.1 -7.5 11/17/2005 12:40:00 14.2 1 16.4 11.8 14.4 1.1 16.8 11.1 358 5 353 305 -7.5 0.1 -7.1 -7.7 11/17/2005 12:50:00 14.4 1 17.2 10.7 14.6 1 16.8 10.7 357 5 358 305 -7.6 0.1 -7.3 -7.9 11/17/2005 13:00:00 14.4 1 16.8 11.5 14.6 1.1 17.2 11.5 352 6 347 305 -7.4 0.2 -6.9 -7.7 11/17/2005 13:10:00 14.8 1.2 17.2 10.7 15 1.3 17.6 11.1 351 4 351 305 -7.5 0.1 -7.1 -7.7 11/17/2005 13:20:00 14.9 1 16.8 11.5 15.1 1.1 17.9 11.1 352 4 353 305 -7.7 0 -7.3 -7.7 11/17/2005 13:30:00 14.6 1.1 16.8 11.1 14.8 1.2 17.2 11.1 353 5 354 305 -7.6 0.1 -7.3 -7.7 11/17/2005 13:40:00 15.4 1 17.6 12.2 15.7 1.1 18.3 12.2 355 5 345 305 -7.6 0 -7.3 -7.9 11/17/2005 13:50:00 16 1.3 18.7 11.5 16.2 1.4 18.7 11.8 353 5 355 305 -7.7 0.2 -7.3 -8.2 11/17/2005 14:00:00 15.7 1.4 19.5 12.6 15.9 1.5 19.9 12.6 350 5 351 305 -7.9 0.1 -7.7 -8.2 11/17/2005 14:10:00 15.6 1.3 19.1 11.1 15.9 1.4 19.5 11.5 355 6 352 305 -7.9 0.1 -7.7 -8.2 11/17/2005 14:20:00 15.9 1 18.7 12.6 16.1 1.1 18.3 13 354 5 351 305 -8 0.1 -7.7 -8.2 11/17/2005 14:30:00 16.2 1 18.7 13 16.4 1.1 19.1 13.3 352 5 353 305 -8 0.1 -7.7 -8.2 11/17/2005 14:40:00 15.8 1.2 18.7 12.2 15.9 1.3 19.1 12.6 356 4 0 305 -8.2 0 -7.7 -8.4 11/17/2005 14:50:00 15.4 1.1 17.6 12.2 15.6 1.2 17.9 12.2 355 5 349 305 -8.2 0 -7.7 -8.4 11/17/2005 15:00:00 15.8 1.1 18.7 12.2 16 1.2 19.1 12.2 357 6 351 305 -8.1 0.1 -7.7 -8.4 11/17/2005 15:10:00 15.7 1.2 18.7 11.5 15.9 1.3 19.1 11.8 357 6 356 305 -8.2 0 -7.7 -8.4 11/17/2005 15:20:00 15.3 1.2 17.9 12.2 15.6 1.2 18.3 12.6 358 5 350 305 -8.2 0 -7.9 -8.4 11/17/2005 15:30:00 15.5 1.3 18.7 12.6 15.6 1.3 18.7 12.6 356 5 0 305 -8.2 0 -7.7 -8.4 11/17/2005 15:40:00 14.9 1.7 18.7 10.3 15.1 1.8 19.1 10.3 356 6 351 305 -8 0.2 -7.7 -8.4 11/17/2005 15:50:00 15.5 1.3 18.3 11.8 15.6 1.3 19.1 12.2 1 5 1 305 -8.3 0 -7.9 -8.6 11/17/2005 16:00:00 16.3 1.5 19.9 12.2 16.5 1.6 19.5 12.6 356 5 354 305 -8.2 0.1 -7.7 -8.4 11/17/2005 16:10:00 16.3 1.1 19.1 13.3 16.5 1.3 19.1 13 355 4 1 305 -8.3 0 -8.2 -8.6 11/17/2005 16:20:00 16.1 1 18.3 13.3 16.3 1.1 18.7 13.3 359 6 9 305 -8.2 0 -7.9 -8.4 11/17/2005 16:30:00 15.5 1.5 17.9 11.5 15.6 1.6 18.7 11.5 358 5 2 305 -7.9 0.1 -7.5 -8.2 11/17/2005 16:40:00 15.6 1 17.9 12.2 15.8 1.2 18.3 12.6 3 6 358 305 -8 0.1 -7.7 -8.2 11/17/2005 16:50:00 15.1 1.1 18.3 11.8 15.3 1.2 18.3 12.2 0 6 9 305 -7.9 0 -7.7 -8.2 11/17/2005 17:00:00 15.2 1.1 17.6 11.8 15.4 1.3 18.3 11.5 4 6 8 305 -7.9 0 -7.5 -8.2 11/17/2005 17:10:00 15.3 1 17.9 12.6 15.4 1.1 17.6 11.8 3 5 1 305 -7.8 0 -7.3 -7.9 11/17/2005 17:20:00 14.7 1.1 17.6 11.8 14.9 1.2 17.9 11.5 1 5 0 305 -7.7 0 -7.3 -7.9 11/17/2005 17:30:00 15 1.3 17.9 11.5 15.1 1.3 18.3 11.1 2 5 4 305 -7.7 0 -7.3 -7.9 11/17/2005 17:40:00 14.7 1.1 17.2 11.5 15 1.2 17.6 10.7 6 4 5 305 -7.7 0 -7.5 -7.9 11/17/2005 17:50:00 15.2 1.1 17.9 11.5 15.3 1.3 18.3 11.1 5 5 357 305 -7.7 0.1 -7.1 -7.9 11/17/2005 18:00:00 15.8 1.2 18.3 11.8 15.9 1.3 18.7 11.8 6 5 7 305 -7.7 0 -7.3 -7.9 11/17/2005 18:10:00 16.1 1.3 19.1 11.5 16.3 1.3 19.1 11.5 6 5 8 305 -7.6 0 -7.3 -7.9 11/17/2005 18:20:00 15.6 1.3 19.1 12.2 15.7 1.4 19.5 12.6 6 5 359 305 -7.5 0.1 -7.1 -7.7 11/17/2005 18:30:00 15.7 1.3 19.1 12.2 15.8 1.3 19.1 12.2 6 5 8 305 -7.5 0.1 -7.1 -7.7 11/17/2005 18:40:00 16.1 1.1 18.3 12.6 16.1 1.2 19.1 13 4 4 3 305 -7.6 0 -7.3 -7.7 11/17/2005 18:50:00 16.6 1.4 19.9 12.6 16.7 1.5 20.2 12.6 5 5 7 305 -7.6 0.1 -7.1 -7.7 11/17/2005 19:00:00 16.4 1.2 19.5 13.3 16.5 1.3 19.9 13.3 4 6 357 305 -7.5 0.1 -7.1 -7.7 11/17/2005 19:10:00 16.1 1.3 19.1 12.2 16.2 1.5 19.1 12.6 6 4 11 305 -7.6 0 -7.3 -7.9 11/17/2005 19:20:00 16.2 1.3 19.1 12.6 16.3 1.3 19.5 11.8 8 5 5 305 -7.7 0 -7.5 -7.9 11/17/2005 19:30:00 15.9 1.5 19.1 11.8 16.1 1.6 19.1 12.2 5 5 359 305 -7.8 0.1 -7.5 -8.2 11/17/2005 19:40:00 16.4 1.3 19.5 13 16.5 1.4 19.5 12.2 3 5 355 305 -7.7 0 -7.5 -7.9 11/17/2005 19:50:00 16.2 1.5 19.1 12.6 16.3 1.6 19.5 11.8 4 4 357 305 -7.7 0 -7.3 -7.9 11/17/2005 20:00:00 16 1.5 20.2 12.2 16.2 1.5 19.9 11.8 1 5 1 305 -7.8 0.1 -7.3 -8.2 11/17/2005 20:10:00 16.4 1.3 19.1 12.2 16.5 1.3 19.5 12.6 2 5 356 305 -7.8 0 -7.3 -7.9 11/17/2005 20:20:00 16.5 1.5 20.2 11.5 16.6 1.6 19.9 11.5 359 5 9 305 -7.7 0.1 -7.3 -7.9 11/17/2005 20:30:00 15.8 1.3 19.9 12.2 15.9 1.3 20.2 12.6 2 5 357 305 -7.6 0 -7.1 -7.9 11/17/2005 20:40:00 16.5 1.4 19.5 12.6 16.6 1.5 20.2 11.8 1 6 349 305 -7.6 0 -7.3 -7.9 11/17/2005 20:50:00 16.3 1.2 19.5 12.2 16.5 1.2 19.5 11.8 3 5 1 305 -7.7 0.1 -7.3 -7.9 11/17/2005 21:00:00 16.2 1.4 19.5 13.3 16.2 1.5 19.9 12.2 2 5 358 305 -7.7 0 -7.5 -7.9 11/17/2005 21:10:00 16.4 1.5 19.5 12.6 16.5 1.5 19.9 12.2 3 5 5 305 -7.6 0 -7.3 -7.9 11/17/2005 21:20:00 16 1.3 18.7 12.2 16.1 1.4 19.9 12.6 3 5 356 305 -7.7 0 -7.3 -7.9 11/17/2005 21:30:00 16.1 1.5 19.5 12.2 16.3 1.5 19.5 12.2 359 5 359 305 -7.6 0 -7.3 -7.7 11/17/2005 21:40:00 15.9 1.3 19.5 12.6 16 1.5 20.2 11.5 2 5 2 305 -7.5 0.1 -7.3 -7.7 11/17/2005 21:50:00 15.4 1.4 19.5 11.5 15.6 1.5 19.5 11.8 4 6 8 305 -7.3 0 -7.1 -7.5 11/17/2005 22:00:00 15.4 1.3 18.7 12.6 15.5 1.5 19.1 11.8 6 5 10 305 -7.2 0 -6.9 -7.3 11/17/2005 22:10:00 15.7 1.4 19.1 11.8 15.8 1.4 19.1 12.2 5 6 2 305 -7.2 0 -6.9 -7.5 11/17/2005 22:20:00 15.7 1.5 19.1 11.8 15.9 1.7 19.9 11.8 0 5 355 305 -7 0 -6.7 -7.3 11/17/2005 22:30:00 15.8 1.5 18.7 11.8 15.9 1.6 19.1 11.5 5 5 2 305 -7 0 -6.7 -7.1 11/17/2005 22:40:00 16.1 1.3 19.1 11.8 16.3 1.4 19.5 11.5 5 5 4 305 -7.1 0 -6.7 -7.3 11/17/2005 22:50:00 16.5 1.3 19.1 12.6 16.6 1.3 19.9 13 3 5 2 305 -7 0.1 -6.7 -7.3 11/17/2005 23:00:00 16.4 1.2 19.5 13.7 16.5 1.2 19.9 12.6 4 5 10 305 -6.9 0 -6.4 -7.3 11/17/2005 23:10:00 15.7 1.3 19.1 12.2 15.7 1.4 18.7 12.6 6 6 8 305 -6.7 0 -6.4 -7.1 11/17/2005 23:20:00 16.3 1.5 20.2 12.6 16.3 1.5 20.2 11.8 4 5 6 305 -6.6 0 -6.2 -6.9 11/17/2005 23:30:00 17.1 1.3 19.9 13.3 17.2 1.5 20.6 12.6 2 5 8 305 -6.5 0.1 -6.2 -6.9 11/17/2005 23:40:00 16.8 1.4 19.9 13 16.9 1.5 20.6 13 1 5 356 305 -6.5 0.1 -6 -6.9 11/17/2005 23:50:00 17.3 1.5 19.9 11.8 17.4 1.5 21 11.8 1 5 357 305 -6.8 0 -6.4 -6.9 11/18/2005 00:00:00 17 1.4 19.9 13.7 17.2 1.4 20.2 13.7 4 5 359 305 -6.8 0 -6.4 -7.1 11/18/2005 00:10:00 16.5 1.3 19.5 12.2 16.5 1.5 19.9 12.2 4 5 3 305 -6.8 0 -6.7 -6.9 11/18/2005 00:20:00 16 1.4 19.1 11.5 16.2 1.4 19.5 12.2 1 5 356 305 -6.7 0.1 -6.2 -6.9 11/18/2005 00:30:00 16.2 1.4 19.9 12.6 16.3 1.5 19.9 13 1 6 355 305 -6.8 0.1 -6.4 -7.1 11/18/2005 00:40:00 16.3 1.3 19.5 12.6 16.4 1.5 19.5 12.2 359 5 355 305 -7 0.1 -6.7 -7.3 11/18/2005 00:50:00 16.1 1.3 18.7 12.2 16.2 1.3 19.1 11.5 359 4 1 305 -6.9 0.1 -6.7 -7.1 11/18/2005 01:00:00 16.6 1.3 19.5 12.6 16.7 1.4 19.9 12.2 1 4 2 305 -7 0.1 -6.7 -7.3 11/18/2005 01:10:00 16.3 1.3 19.5 12.6 16.5 1.4 20.2 13 358 5 356 305 -7.1 0 -6.7 -7.3 11/18/2005 01:20:00 17.1 1.3 19.9 13.3 17.2 1.5 20.2 13 359 7 354 305 -7 0.1 -6.7 -7.3 11/18/2005 01:30:00 17.2 1.3 20.2 13.3 17.3 1.3 19.9 13.7 359 5 359 305 -7 0 -6.7 -7.1 11/18/2005 01:40:00 17.4 1.1 19.9 14.5 17.5 1.1 20.2 13.7 359 5 1 305 -7 0 -6.7 -7.3 11/18/2005 01:50:00 17.5 1.4 20.6 13 17.6 1.5 20.6 13 359 6 2 305 -7 0.1 -6.7 -7.3 11/18/2005 02:00:00 17.6 1.3 21.4 13.7 17.7 1.5 21.8 13.7 0 5 0 305 -6.9 0.1 -6.7 -7.1 11/18/2005 02:10:00 18.2 1.3 20.6 13.7 18.2 1.5 21 13.3 356 5 354 305 -7 0.1 -6.7 -7.3 11/18/2005 02:20:00 18.3 1.6 21.8 13.7 18.3 1.7 22.1 13.7 355 5 348 305 -7 0.1 -6.7 -7.1 11/18/2005 02:30:00 18.2 1.6 21.4 13.7 18.2 1.7 22.1 13.3 355 6 351 305 -7 0.1 -6.7 -7.3 11/18/2005 02:40:00 17.6 1.9 22.1 12.2 17.7 2 21.8 12.2 356 5 358 305 -7 0.1 -6.7 -7.3 11/18/2005 02:50:00 17.3 1.7 21.8 13.7 17.5 1.8 22.6 13.7 357 5 358 305 -7 0.1 -6.7 -7.3 11/18/2005 03:00:00 17.9 1.3 21 13.3 18.1 1.3 20.6 14.1 358 5 357 305 -7 0.1 -6.7 -7.3 11/18/2005 03:10:00 17.9 1.2 21 14.9 18.1 1.3 21 14.5 357 5 355 305 -7 0 -6.9 -7.1 11/18/2005 03:20:00 17.9 1.1 20.6 14.5 18.1 1.2 20.6 15.3 356 4 359 305 -7.2 0 -7.1 -7.3 11/18/2005 03:30:00 17.6 1.5 21.4 13 17.8 1.5 21.8 13.7 355 5 355 305 -7.2 0 -6.9 -7.3 11/18/2005 03:40:00 17.9 1.5 21.4 13.7 18 1.4 21.8 14.5 355 5 353 305 -7.1 0 -6.9 -7.3 11/18/2005 03:50:00 17.1 1.3 20.2 13.3 17.2 1.5 20.6 13 355 4 355 305 -7.1 0.1 -6.9 -7.3 11/18/2005 04:00:00 17.5 1.7 22.1 12.6 17.6 1.8 21.8 13.3 357 5 5 305 -7.1 0 -6.9 -7.3 11/18/2005 04:10:00 17.8 1.5 21.4 13 17.9 1.6 21.8 13.3 358 5 355 305 -7.1 0 -6.7 -7.3 11/18/2005 04:20:00 18.4 1.2 21.4 14.1 18.4 1.2 21.4 14.5 357 4 354 305 -7.1 0 -6.9 -7.3 11/18/2005 04:30:00 18 1.7 21.8 13.7 18 1.7 21.8 13.3 358 5 357 305 -7 0.1 -6.7 -7.3 11/18/2005 04:40:00 18 1.3 21 13.3 18 1.5 21.4 14.1 356 4 352 305 -7 0 -6.7 -7.1 11/18/2005 04:50:00 18 1.5 20.6 13.7 18.1 1.5 21 14.1 351 5 353 305 -7.2 0 -6.9 -7.3 11/18/2005 05:00:00 17.8 1.4 21.4 13.3 17.8 1.5 21.4 13.3 355 6 352 305 -7 0.1 -6.7 -7.3 11/18/2005 05:10:00 17.5 1.4 21 13 17.7 1.5 20.6 13 353 5 347 305 -7.1 0 -6.7 -7.3 11/18/2005 05:20:00 18.2 1.4 21 13.7 18.2 1.5 21.4 13.7 356 5 357 305 -7 0.1 -6.7 -7.3 11/18/2005 05:30:00 18.7 1.8 22.1 13.7 18.9 1.7 22.1 14.1 355 5 358 305 -7 0.1 -6.7 -7.3 11/18/2005 05:40:00 18.5 1.5 22.1 14.9 18.5 1.6 22.6 13.7 354 5 351 305 -7 0.1 -6.7 -7.1 11/18/2005 05:50:00 18.1 1.4 21.8 13.7 18.1 1.4 21.4 14.1 353 5 355 305 -7 0.1 -6.7 -7.3 11/18/2005 06:00:00 17.9 1.9 21.8 13.3 18 2 21.8 13.7 355 5 351 305 -7 0.1 -6.4 -7.1 11/18/2005 06:10:00 18.4 1.4 21.8 14.1 18.5 1.5 22.6 14.9 356 4 353 305 -7 0.1 -6.7 -7.3 11/18/2005 06:20:00 18.5 1.5 21.8 13.7 18.6 1.5 22.1 13.3 357 5 356 305 -7 0.1 -6.7 -7.3 11/18/2005 06:30:00 18.9 1.4 21.8 14.9 19 1.5 22.6 15.3 356 5 353 305 -7.2 0 -6.9 -7.5 11/18/2005 06:40:00 18.6 1.5 23.3 14.9 18.7 1.6 22.9 14.5 356 5 358 305 -7.2 0 -6.9 -7.5 11/18/2005 06:50:00 18.7 1.5 22.1 14.1 18.9 1.6 22.9 14.5 356 5 0 305 -7.3 0.1 -6.9 -7.5 11/18/2005 07:00:00 18.8 1.6 22.6 14.1 18.8 1.7 22.6 14.1 355 5 0 305 -7.4 0 -7.1 -7.7 11/18/2005 07:10:00 19.1 1.3 22.6 15.3 19.1 1.4 22.6 16.1 356 4 352 305 -7.4 0 -7.1 -7.7 11/18/2005 07:20:00 19 1.5 22.9 14.1 19.2 1.5 23.3 15.3 356 5 352 305 -7.5 0.1 -7.1 -7.7 11/18/2005 07:30:00 18.5 1.7 21.8 14.1 18.6 1.8 22.6 14.5 356 6 354 305 -7.5 0.1 -7.1 -7.7 11/18/2005 07:40:00 18.3 1.6 22.6 13.7 18.5 1.7 22.6 13.3 355 5 355 305 -7.4 0 -7.1 -7.7 11/18/2005 07:50:00 18.1 1.4 21.4 13.3 18.2 1.6 22.1 13.3 353 5 354 305 -7.5 0 -7.3 -7.7 11/18/2005 08:00:00 18.5 1.6 22.1 13.7 18.6 1.7 22.6 13.7 353 5 352 305 -7.7 0 -7.3 -7.9 11/18/2005 08:10:00 18.8 1.7 22.1 14.1 18.9 1.8 22.9 13 353 4 355 305 -7.7 0 -7.3 -7.9 11/18/2005 08:20:00 18.7 1.5 21.8 13 18.8 1.6 22.1 14.5 356 5 349 305 -7.7 0 -7.3 -7.9 11/18/2005 08:30:00 18.6 1.7 22.6 14.1 18.7 1.7 22.9 14.9 354 6 350 305 -7.7 0 -7.3 -7.9 11/18/2005 08:40:00 18.8 1.9 22.1 13.3 18.8 2.1 22.6 13.3 356 5 358 305 -7.7 0 -7.3 -7.9 11/18/2005 08:50:00 19.2 1.4 22.6 16.1 19.2 1.3 23.3 15.6 354 4 353 305 -7.7 0 -7.5 -7.9 11/18/2005 09:00:00 19 1.9 22.9 13.7 19.1 1.9 22.9 13.7 351 4 349 305 -7.7 0 -7.3 -7.9 11/18/2005 09:10:00 19.2 1.6 22.6 14.5 19.2 1.7 22.6 14.5 352 4 358 305 -7.7 0 -7.3 -7.9 11/18/2005 09:20:00 19.2 1.7 22.6 14.5 19.1 1.9 22.9 13.7 351 5 358 305 -7.7 0 -7.3 -7.9 11/18/2005 09:30:00 19.6 1.6 22.6 14.1 19.8 1.7 23.3 15.3 351 5 354 305 -7.8 0 -7.3 -7.9 11/18/2005 09:40:00 18.6 1.5 22.1 14.5 18.7 1.5 22.1 14.1 352 5 350 305 -7.8 0 -7.3 -7.9 11/18/2005 09:50:00 19.3 1.5 22.9 13.7 19.4 1.5 23.3 14.5 352 5 352 305 -7.8 0 -7.3 -7.9 11/18/2005 10:00:00 18.9 1.3 21.8 15.3 19.1 1.5 22.1 15.3 351 5 358 305 -7.7 0 -7.3 -7.7 11/18/2005 10:10:00 18.4 1.4 21.8 14.5 18.5 1.5 22.1 14.9 354 5 352 305 -7.6 0 -7.3 -7.9 11/18/2005 10:20:00 18.5 1.5 22.6 14.5 18.7 1.6 23.3 14.9 352 5 353 305 -7.8 0.1 -7.3 -8.2 11/18/2005 10:30:00 18.4 1.5 22.6 14.1 18.6 1.7 21.8 13.7 355 5 354 305 -7.7 0 -7.3 -7.9 11/18/2005 10:40:00 19.3 1.4 22.6 14.9 19.5 1.5 22.9 14.9 353 4 355 305 -7.9 0 -7.5 -8.2 11/18/2005 10:50:00 19.5 2.1 24 13.7 19.6 2.1 24.8 14.1 351 4 345 305 -7.8 0.1 -7.3 -8.2 11/18/2005 11:00:00 19.4 1.5 22.9 15.3 19.6 1.7 23.3 15.3 351 4 344 305 -7.8 0 -7.5 -7.9 11/18/2005 11:10:00 19.3 1.6 22.6 13.3 19.5 1.6 23.7 14.1 349 5 351 305 -7.8 0.1 -7.3 -8.2 11/18/2005 11:20:00 18.8 1.6 23.3 14.9 18.8 1.7 24 14.5 347 5 346 305 -7.8 0.1 -7.3 -8.2 11/18/2005 11:30:00 18.9 1.8 23.3 13.3 18.9 1.8 22.9 13 348 5 345 305 -7.7 0.1 -7.3 -7.9 11/18/2005 11:40:00 18.5 1.9 22.6 13.3 18.6 1.8 22.9 13.7 350 5 353 305 -7.8 0 -7.5 -8.2 11/18/2005 11:50:00 18.2 1.7 23.3 13.3 18.4 1.7 22.6 14.5 351 5 348 305 -7.8 0 -7.5 -7.9 11/18/2005 12:00:00 18.6 1.9 22.9 13.7 18.8 1.9 23.3 14.9 352 4 349 305 -7.8 0.1 -7.5 -8.2 11/18/2005 12:10:00 19.6 1.9 23.7 14.1 19.7 2 24.4 13.7 352 5 351 305 -7.8 0.1 -7.3 -8.2 11/18/2005 12:20:00 19 1.5 22.9 14.5 19.1 1.7 22.6 13 352 5 355 305 -7.8 0.1 -7.3 -8.2 11/18/2005 12:30:00 19.2 1.7 23.3 13.3 19.3 1.7 23.3 14.1 351 5 351 305 -7.7 0 -7.3 -7.9 11/18/2005 12:40:00 18.4 1.9 21.8 12.6 18.6 1.9 22.6 13.3 352 5 358 305 -7.8 0.1 -7.3 -8.2 11/18/2005 12:50:00 18.6 1.5 22.1 13.7 18.7 1.6 22.6 14.1 353 5 358 305 -7.7 0 -7.3 -8.2 11/18/2005 13:00:00 19.4 1.8 22.9 14.1 19.5 1.8 22.9 14.5 354 5 350 305 -7.7 0 -7.3 -8.2 11/18/2005 13:10:00 17.9 1.7 22.1 13.3 18 1.7 21.8 13.3 355 5 351 305 -7.6 0.2 -7.1 -7.9 11/18/2005 13:20:00 18.7 1.4 22.1 14.1 18.7 1.5 21.8 14.1 351 5 352 305 -7.7 0.1 -7.1 -7.9 11/18/2005 13:30:00 19.5 1.6 23.7 13.7 19.7 1.7 24 14.1 352 5 358 305 -7.8 0.1 -7.5 -8.2 11/18/2005 13:40:00 18.9 1.7 22.1 14.1 19.1 1.7 22.9 13.7 352 5 2 305 -7.8 0.2 -7.3 -8.2 11/18/2005 13:50:00 19.5 1.7 24 15.3 19.6 1.8 24 14.5 351 5 350 305 -7.9 0.2 -7.3 -8.2 11/18/2005 14:00:00 18.7 2 22.9 13.7 18.7 2 23.7 14.1 353 5 359 305 -7.7 0.1 -7.3 -8.2 11/18/2005 14:10:00 19.3 1.8 23.7 14.5 19.5 1.8 24 15.3 355 5 345 305 -7.6 0.1 -7.1 -7.9 11/18/2005 14:20:00 19.8 1.7 22.9 14.5 19.8 1.8 23.7 15.3 354 4 353 305 -7.8 0.1 -7.3 -8.2 11/18/2005 14:30:00 19.7 1.6 22.9 13.7 19.6 1.7 22.9 13 355 5 354 305 -7.7 0.1 -7.3 -7.9 11/18/2005 14:40:00 19.8 1.7 23.7 15.3 19.8 1.8 24.4 14.9 354 5 355 305 -7.7 0 -7.3 -7.9 11/18/2005 14:50:00 19.9 1.8 23.7 14.5 20.1 1.9 23.7 14.9 351 5 352 305 -7.8 0 -7.3 -8.2 11/18/2005 15:00:00 19.9 2.1 23.7 14.9 19.9 2.1 24 14.5 352 5 349 305 -7.7 0.2 -7.1 -8.2 11/18/2005 15:10:00 20.3 1.6 23.7 16.1 20.3 1.7 24 15.3 353 5 350 305 -7.8 0.1 -7.3 -7.9 11/18/2005 15:20:00 20 1.7 24.4 16.1 20 1.8 24.8 15.6 351 5 351 305 -7.7 0 -7.3 -7.9 11/18/2005 15:30:00 19.4 1.8 23.7 14.9 19.5 1.9 24 14.9 352 5 356 305 -7.7 0.1 -7.3 -7.9 11/18/2005 15:40:00 19.8 2 24 14.5 19.9 2 23.7 14.9 354 5 355 305 -7.8 0 -7.3 -8.2 11/18/2005 15:50:00 20.5 1.7 23.7 14.5 20.6 1.7 25.2 15.6 354 4 351 305 -7.9 0 -7.7 -8.2 11/18/2005 16:00:00 19.6 1.7 23.3 14.9 19.7 1.7 23.3 13.3 354 5 2 305 -7.8 0.1 -7.3 -7.9 11/18/2005 16:10:00 19.8 1.8 23.7 14.5 19.8 1.9 23.7 14.9 353 5 356 305 -7.8 0.1 -7.3 -7.9 11/18/2005 16:20:00 20.4 1.6 24.8 16.4 20.3 1.7 24.8 15.6 355 5 358 305 -7.8 0.1 -7.3 -8.2 11/18/2005 16:30:00 20.5 1.7 24.4 15.3 20.6 1.8 24.4 15.6 354 4 1 305 -8 0.1 -7.5 -8.2 11/18/2005 16:40:00 20.2 1.8 24.4 15.6 20.2 2 24.8 15.3 353 5 354 305 -7.8 0.1 -7.3 -8.2 11/18/2005 16:50:00 19.8 1.7 25.2 15.3 19.8 1.8 24 14.9 353 5 356 305 -7.8 0.2 -7.3 -8.2 11/18/2005 17:00:00 19.2 1.9 23.3 14.1 19.2 2 23.3 14.1 354 5 357 305 -7.7 0.1 -7.3 -7.9 11/18/2005 17:10:00 20.8 1.7 24.8 15.3 20.9 1.9 25.6 16.1 356 5 351 305 -7.8 0 -7.3 -7.9 11/18/2005 17:20:00 21.3 1.8 25.2 14.5 21.3 1.9 25.2 14.9 352 4 352 305 -7.8 0 -7.5 -7.9 11/18/2005 17:30:00 20.8 1.7 24.8 15.3 20.9 1.7 25.2 15.6 353 4 348 305 -7.9 0.1 -7.5 -8.2 11/18/2005 17:40:00 19.7 1.7 22.9 14.5 19.7 1.7 23.7 15.3 357 5 355 305 -7.6 0.1 -7.1 -7.9 11/18/2005 17:50:00 20.5 1.6 23.7 16.1 20.5 1.7 23.7 15.6 354 5 358 305 -7.7 0 -7.3 -7.9 11/18/2005 18:00:00 20.3 2 24.4 14.5 20.3 2.1 24.8 14.5 353 4 354 305 -7.7 0.1 -7.1 -7.9 11/18/2005 18:10:00 20.1 1.7 24 15.3 20 1.8 24 14.5 353 5 350 305 -7.6 0 -7.3 -7.7 11/18/2005 18:20:00 20.2 2.1 24.8 14.5 20.1 2.1 24.4 13.7 352 5 348 305 -7.5 0.1 -7.1 -7.7 11/18/2005 18:30:00 20.4 1.8 24.4 15.3 20.4 1.9 24.8 14.9 354 5 353 305 -7.5 0.1 -6.9 -7.9 11/18/2005 18:40:00 20 2.1 24 14.5 20 2 24 14.9 354 5 357 305 -7.4 0.1 -6.9 -7.7 11/18/2005 18:50:00 20 1.8 24 14.5 20 1.9 24 14.5 352 5 350 305 -7.5 0.1 -7.1 -7.7 11/18/2005 19:00:00 20.1 1.8 24.4 15.3 20.5 1.9 24.4 15.6 351 5 348 305 -7.6 0 -7.3 -7.7 11/18/2005 19:10:00 20.2 1.7 24 16.1 20.4 1.8 24.8 15.6 351 5 351 305 -7.6 0.1 -7.1 -7.9 11/18/2005 19:20:00 20.3 1.7 24 16.1 20.5 1.8 24.8 15.3 353 5 358 305 -7.7 0 -7.3 -7.9 11/18/2005 19:30:00 19.4 2 23.7 13.7 19.6 2.1 23.7 14.5 355 5 351 305 -7.6 0.1 -7.1 -7.7 11/18/2005 19:40:00 19.8 1.7 24.4 15.3 19.9 1.7 24.4 14.9 354 5 1 305 -7.7 0 -7.3 -7.9 11/18/2005 19:50:00 19.9 1.7 23.3 14.5 20.1 1.7 24.4 14.5 350 5 351 305 -7.6 0 -7.1 -7.7 11/18/2005 20:00:00 20 1.6 23.3 16.4 20.1 1.7 24.4 16.1 352 5 350 305 -7.6 0 -7.3 -7.9 11/18/2005 20:10:00 20.7 1.5 23.3 16.1 20.9 1.6 24 16.1 351 4 344 305 -7.7 0.1 -7.3 -7.9 11/18/2005 20:20:00 20.1 2 24.4 14.9 20.4 2 24.8 14.9 351 5 347 305 -7.7 0.1 -7.3 -7.9 11/18/2005 20:30:00 19.8 1.8 24 14.5 20 1.9 24.8 14.9 352 5 357 305 -7.6 0.1 -7.1 -7.9 11/18/2005 20:40:00 19.4 1.7 24 14.1 19.5 2 24 13.3 352 5 354 305 -7.5 0.1 -7.1 -7.7 11/18/2005 20:50:00 19.5 2.1 24.4 14.9 19.5 2.1 24.8 14.9 354 5 350 305 -7.4 0.1 -7.1 -7.7 11/18/2005 21:00:00 19.5 1.8 24.4 15.3 19.6 2 24.4 14.5 353 5 358 305 -7.4 0.1 -7.1 -7.7 11/18/2005 21:10:00 19.7 1.8 27.1 14.9 19.6 1.9 27.9 14.9 353 5 355 305 -7.4 0 -7.1 -7.7 11/18/2005 21:20:00 18.9 2.1 26.8 13.7 18.9 2.2 26.8 14.5 358 5 358 305 -7.4 0 -7.1 -7.7 11/18/2005 21:30:00 19.8 1.8 24 13.3 19.7 1.9 24 14.9 356 5 353 305 -7.5 0 -7.3 -7.7 11/18/2005 21:40:00 19.6 1.3 22.6 14.5 19.6 1.4 22.9 16.1 357 6 8 305 -7.4 0 -7.1 -7.7 11/18/2005 21:50:00 19.8 2 24 13.7 19.5 1.9 24 13.7 7 7 9 305 -7 0 -6.7 -7.3 11/18/2005 22:00:00 20.4 1.7 24.4 14.9 20.1 1.7 25.2 15.3 12 5 8 305 -7 0.1 -6.7 -7.3 11/18/2005 22:10:00 21.8 1.7 26.8 16.4 21.5 1.7 26.3 16.4 13 5 12 305 -7.1 0 -6.9 -7.3 11/18/2005 22:20:00 21.3 1.7 25.6 17.2 20.9 1.8 25.6 16.1 11 5 10 305 -7 0.1 -6.7 -7.3 11/18/2005 22:30:00 21.1 2 25.2 16.1 20.8 2 25.6 14.9 10 5 11 305 -7.1 0 -6.9 -7.3 11/18/2005 22:40:00 21.1 2 25.6 14.9 21 2 25.6 14.9 8 5 18 305 -7 0.1 -6.7 -7.1 11/18/2005 22:50:00 21.7 2.3 26.8 16.8 21.4 2.4 26.3 15.3 14 5 17 305 -7 0.1 -6.7 -7.3 11/18/2005 23:00:00 21.4 2.3 26.3 15.3 21.2 2.3 26.3 14.9 14 6 21 305 -6.8 0 -6.2 -6.9 11/18/2005 23:10:00 20.9 2.3 26.8 14.9 20.7 2.2 27.1 15.3 10 7 19 305 -6.9 0.1 -6.7 -7.1 11/18/2005 23:20:00 18.8 1.8 22.6 13.7 18.8 1.8 22.9 14.1 3 6 15 305 -6.8 0.1 -6.2 -7.3 11/18/2005 23:30:00 18.9 1.7 23.3 14.1 19 1.8 23.7 14.1 355 6 358 305 -7.1 0 -6.9 -7.3 11/18/2005 23:40:00 19.9 1.9 24 13.3 19.8 1.9 24 14.1 3 6 357 305 -7.2 0 -6.9 -7.3 11/18/2005 23:50:00 18.9 2 23.3 14.5 18.7 2.1 22.9 13 1 7 5 305 -7.4 0 -6.9 -7.7 11/19/2005 00:00:00 17.9 1.6 21.4 13.3 17.9 1.7 21.8 13 1 5 357 305 -7.2 0.1 -6.9 -7.5 11/19/2005 00:10:00 17.9 1.8 22.1 13.3 17.9 1.9 21.8 13.3 359 5 2 305 -7.4 0 -6.9 -7.7 11/19/2005 00:20:00 18.4 1.7 22.9 14.1 18.2 1.7 22.9 14.1 355 5 355 305 -7.2 0 -6.7 -7.5 11/19/2005 00:30:00 17.7 1.4 21 13.7 17.7 1.5 21.4 13.3 355 6 356 305 -7.1 0.1 -6.7 -7.5 11/19/2005 00:40:00 19 1.7 22.6 14.1 18.9 1.7 22.6 13.3 350 5 348 305 -7.4 0.1 -6.9 -7.7 11/19/2005 00:50:00 18.8 1.5 22.1 14.1 18.7 1.6 22.6 14.1 350 5 352 305 -7.4 0.1 -6.9 -7.7 11/19/2005 01:00:00 18.7 1.3 21.8 14.9 18.6 1.5 21.8 14.9 351 5 341 305 -7.3 0.1 -6.9 -7.7 11/19/2005 01:10:00 19.2 1.8 23.3 13.7 19 1.9 23.7 13.3 352 5 353 305 -7.3 0.1 -6.9 -7.5 11/19/2005 01:20:00 19.1 1.6 22.6 14.9 19 1.7 22.9 14.9 350 5 345 305 -7.4 0.1 -7.1 -7.7 11/19/2005 01:30:00 19.6 1.6 23.3 15.6 19.5 1.6 23.3 15.6 350 5 352 305 -7.4 0.1 -6.9 -7.7 11/19/2005 01:40:00 20.3 1.4 23.3 14.9 20.1 1.5 22.9 15.3 350 4 349 305 -7.5 0.1 -7.1 -7.7 11/19/2005 01:50:00 19.1 1.5 23.3 14.5 19 1.6 23.3 14.1 352 5 354 305 -7.4 0 -6.9 -7.5 11/19/2005 02:00:00 18.7 1.7 22.6 14.1 18.5 1.8 22.9 13.7 353 4 354 305 -7.3 0.1 -6.9 -7.5 11/19/2005 02:10:00 19.1 1.6 24.4 15.3 18.9 1.7 23.7 14.5 353 5 352 305 -7.2 0.1 -7.1 -7.5 11/19/2005 02:20:00 19 2.2 22.9 13.3 18.9 2.1 23.7 13.7 350 5 357 305 -7.2 0.1 -6.9 -7.5 11/19/2005 02:30:00 19.8 1.7 22.9 15.6 19.7 1.7 23.3 14.9 352 5 353 305 -7.4 0.1 -6.7 -7.7 11/19/2005 02:40:00 19.2 1.7 22.9 14.5 19 1.7 22.9 14.5 350 5 357 305 -7.2 0 -6.9 -7.5 11/19/2005 02:50:00 18.8 1.7 22.6 12.6 18.7 1.8 22.1 13.3 351 5 351 305 -7.2 0.1 -6.9 -7.5 11/19/2005 03:00:00 19.5 1.6 22.6 15.3 19.4 1.6 22.9 13.3 350 5 352 305 -7.3 0.1 -7.1 -7.7 11/19/2005 03:10:00 19.9 1.5 23.3 15.3 19.7 1.5 23.7 14.9 351 4 346 305 -7.4 0 -7.1 -7.7 11/19/2005 03:20:00 19.5 1.5 22.1 14.9 19.3 1.5 22.6 14.5 354 5 352 305 -7.2 0 -7.1 -7.5 11/19/2005 03:30:00 18.7 1.5 22.1 13.7 18.6 1.5 22.1 14.5 353 5 0 305 -7.4 0 -7.1 -7.5 11/19/2005 03:40:00 19.6 1.4 22.6 15.6 19.4 1.5 22.9 15.3 350 4 349 305 -7.2 0 -6.9 -7.5 11/19/2005 03:50:00 19.6 1.9 22.9 14.5 19.3 1.9 22.9 14.1 350 5 355 305 -7.4 0.1 -6.9 -7.7 11/19/2005 04:00:00 19.2 1.7 22.9 14.9 19.1 1.8 23.3 14.1 350 4 344 305 -7.2 0 -6.9 -7.5 11/19/2005 04:10:00 20.1 1.7 23.3 14.9 19.9 1.7 22.9 15.3 351 4 349 305 -7.4 0.1 -6.9 -7.7 11/19/2005 04:20:00 19.6 1.9 23.3 14.5 19.4 2 23.7 14.5 350 5 347 305 -7.2 0 -6.9 -7.5 11/19/2005 04:30:00 20 1.7 23.3 14.9 19.9 1.8 23.3 15.6 349 4 346 305 -7.4 0.2 -6.9 -7.7 11/19/2005 04:40:00 19.9 1.7 23.3 14.9 19.9 1.7 23.3 15.3 350 4 352 305 -7.3 0 -6.9 -7.7 11/19/2005 04:50:00 19.5 1.8 23.3 14.1 19.4 1.8 22.9 14.9 349 5 350 305 -7.2 0 -6.9 -7.5 11/19/2005 05:00:00 19.7 1.6 23.3 14.9 19.5 1.6 22.9 14.5 350 5 350 305 -7.2 0 -6.9 -7.5 11/19/2005 05:10:00 19.1 1.7 22.6 14.1 19.1 1.7 22.6 14.1 350 5 346 305 -7.2 0 -6.9 -7.5 11/19/2005 05:20:00 19.9 1.4 22.9 16.4 19.6 1.4 22.9 15.6 352 4 347 305 -7.2 0 -6.9 -7.5 11/19/2005 05:30:00 19.6 1.7 22.9 15.3 19.4 1.8 23.3 14.5 350 4 350 305 -7.1 0 -6.7 -7.3 11/19/2005 05:40:00 19.7 1.7 22.6 14.5 19.5 1.7 22.6 13.7 352 5 348 305 -7.2 0 -6.9 -7.5 11/19/2005 05:50:00 18.8 1.9 22.1 13.3 18.7 1.8 22.6 13.7 353 5 353 305 -7.1 0 -6.7 -7.3 11/19/2005 06:00:00 19.3 1.5 22.6 15.3 19 1.5 22.6 14.9 354 5 353 305 -7.1 0 -6.9 -7.3 11/19/2005 06:10:00 18.8 1.6 22.6 14.9 18.5 1.6 22.6 14.5 352 5 346 305 -7.2 0 -7.1 -7.5 11/19/2005 06:20:00 19.6 1.5 22.6 15.6 19.4 1.5 22.9 15.3 352 5 348 305 -7.1 0 -7.1 -7.3 11/19/2005 06:30:00 19 2.2 23.3 13.7 18.9 2.2 23.7 13 351 5 351 305 -7.1 0 -6.9 -7.3 11/19/2005 06:40:00 19.3 1.5 23.3 14.5 19.3 1.6 23.3 15.3 352 4 351 305 -7 0.1 -6.7 -7.3 11/19/2005 06:50:00 18.6 2.1 23.3 13 18.7 2.1 23.3 13 352 5 344 305 -7.1 0 -6.9 -7.3 11/19/2005 07:00:00 19.1 1.7 22.9 13.7 19 1.8 22.6 13.7 353 5 345 305 -7 0 -6.7 -7.1 11/19/2005 07:10:00 19.4 1.7 22.9 14.1 19.2 1.8 22.6 13 351 5 345 305 -7 0.1 -6.7 -7.1 11/19/2005 07:20:00 19.4 1.6 23.3 15.3 19.3 1.7 22.9 14.9 351 5 350 305 -7 0 -6.7 -7.3 11/19/2005 07:30:00 19.8 1.5 22.9 15.3 19.7 1.6 23.3 15.6 353 5 356 305 -7.1 0 -6.9 -7.3 11/19/2005 07:40:00 20 1.7 23.3 15.6 19.9 1.7 24.4 15.6 353 5 0 305 -7.1 0 -6.9 -7.3 11/19/2005 07:50:00 19.6 1.6 22.9 14.9 19.4 1.6 22.9 14.5 354 5 356 305 -7.1 0.1 -6.7 -7.3 11/19/2005 08:00:00 19.6 1.9 23.7 15.3 19.5 1.7 24 15.3 352 5 350 305 -7.1 0 -6.9 -7.3 11/19/2005 08:10:00 18.3 1.8 23.3 13.7 18.3 2 22.9 13.3 353 5 356 305 -7 0.1 -6.7 -7.3 11/19/2005 08:20:00 19.4 2.1 23.7 14.1 19.4 2 24 14.1 356 4 354 305 -6.9 0.1 -6.4 -7.3 11/19/2005 08:30:00 18.7 1.5 22.6 14.9 18.7 1.6 22.9 14.5 355 4 354 305 -7 0.1 -6.7 -7.1 11/19/2005 08:40:00 19.3 1.6 22.6 14.5 19.2 1.6 22.1 14.1 353 5 351 305 -6.9 0.1 -6.7 -7.1 11/19/2005 08:50:00 19 1.8 22.1 14.1 19 1.8 22.9 14.1 351 5 353 305 -6.9 0.1 -6.4 -7.1 11/19/2005 09:00:00 18.9 1.6 21.8 14.9 19 1.5 22.1 14.5 353 5 344 305 -7 0.1 -6.7 -7.3 11/19/2005 09:10:00 19.1 1.6 22.6 14.5 19.1 1.6 22.6 15.3 352 4 349 305 -6.9 0.1 -6.4 -7.3 11/19/2005 09:20:00 18.8 1.7 23.3 14.9 18.8 1.8 23.7 14.1 352 5 350 305 -6.9 0.1 -6.4 -7.1 11/19/2005 09:30:00 20 1.4 23.7 16.1 19.9 1.5 24 15.6 351 5 346 305 -7 0.1 -6.7 -7.3 11/19/2005 09:40:00 18.5 1.6 21.8 13.3 18.5 1.6 21.8 13.3 353 4 352 305 -6.9 0.1 -6.7 -7.1 11/19/2005 09:50:00 19.7 1.6 22.6 13 19.7 1.6 22.6 13.7 354 5 357 305 -7 0.1 -6.7 -7.1 11/19/2005 10:00:00 18.9 1.7 22.6 14.9 18.9 1.7 22.6 14.5 352 5 356 305 -6.8 0.1 -6.2 -7.1 11/19/2005 10:10:00 19.4 1.7 23.3 15.6 19.4 1.7 22.9 15.3 353 4 347 305 -6.9 0 -6.7 -7.1 11/19/2005 10:20:00 18.7 1.7 23.3 14.5 18.6 1.7 23.3 14.5 352 5 351 305 -6.9 0.1 -6.4 -7.1 11/19/2005 10:30:00 18.9 1.7 22.6 13 18.8 1.7 22.6 13.7 354 5 3 305 -6.9 0.1 -6.7 -7.1 11/19/2005 10:40:00 18.5 1.6 22.9 14.1 18.5 1.7 22.9 13.7 350 4 351 305 -7 0 -6.7 -7.3 11/19/2005 10:50:00 18.8 1.3 21.8 14.5 18.8 1.3 22.1 15.3 353 5 357 305 -7.1 0.1 -6.7 -7.3 11/19/2005 11:00:00 18.1 1.7 22.1 13.3 18.3 1.7 22.6 12.6 351 5 350 305 -7 0 -6.7 -7.1 11/19/2005 11:10:00 18.5 1.6 22.9 14.5 18.5 1.7 22.9 14.1 353 5 352 305 -7 0.1 -6.7 -7.3 11/19/2005 11:20:00 18.4 1.6 21.8 14.5 18.4 1.7 22.1 13.3 351 4 348 305 -7 0 -6.7 -7.3 11/19/2005 11:30:00 17.5 1.5 21 13.7 17.6 1.6 21.4 13.7 349 5 352 305 -7 0.1 -6.7 -7.3 11/19/2005 11:40:00 17.8 1.5 21 13.3 18 1.7 21.4 13.3 351 5 348 305 -7.1 0 -6.9 -7.3 11/19/2005 11:50:00 17.4 1.6 21.8 12.6 17.5 1.6 22.1 13.3 354 5 352 305 -7 0.1 -6.7 -7.1 11/19/2005 12:00:00 18.3 1.5 21.8 13.7 18.4 1.5 21.4 14.1 353 5 351 305 -7 0 -6.7 -7.1 11/19/2005 12:10:00 17.8 1.5 21.4 13.7 17.9 1.5 21.4 13.7 353 5 355 305 -7 0 -6.7 -7.1 11/19/2005 12:20:00 18 1.5 21.8 13.3 18.1 1.5 21.8 13.7 353 5 353 305 -6.9 0 -6.7 -7.1 11/19/2005 12:30:00 17.8 1.3 20.6 14.1 18 1.3 21 14.1 353 5 353 305 -7 0.1 -6.7 -7.1 11/19/2005 12:40:00 18.1 1.5 22.1 13.7 18.2 1.5 22.6 14.1 354 5 350 305 -7 0.1 -6.7 -7.3 11/19/2005 12:50:00 17.6 1.5 20.6 13.3 17.7 1.5 21 13.7 353 5 355 305 -7 0.1 -6.7 -7.1 11/19/2005 13:00:00 18.2 1.5 21.4 14.1 18.4 1.5 21.4 14.1 355 5 356 305 -7 0.1 -6.7 -7.1 11/19/2005 13:10:00 17.8 1.4 21 14.1 17.8 1.5 21 13.7 355 5 352 305 -6.9 0.1 -6.4 -7.3 11/19/2005 13:20:00 18 1.1 20.6 14.1 18.1 1.1 20.6 13.7 351 4 349 305 -7 0 -6.7 -7.1 11/19/2005 13:30:00 17 1.2 19.5 13 17.1 1.2 19.9 13.3 349 4 344 305 -7.1 0 -6.7 -7.3 11/19/2005 13:40:00 17 1.5 21 13.7 17 1.5 21 13.3 352 5 346 305 -7 0.1 -6.7 -7.3 11/19/2005 13:50:00 17.3 1.6 21 13.3 17.4 1.7 20.6 13.3 355 5 355 305 -7 0.1 -6.7 -7.1 11/19/2005 14:00:00 16.4 1.5 19.1 11.8 16.5 1.5 19.5 12.2 354 4 349 305 -7 0.1 -6.4 -7.3 11/19/2005 14:10:00 16.2 1.5 19.1 11.8 16.3 1.6 19.1 12.6 353 5 354 305 -7.2 0.3 -6.7 -7.7 11/19/2005 14:20:00 17.3 1.5 20.6 13 17.3 1.5 20.6 13 356 5 357 305 -7.2 0 -6.9 -7.5 11/19/2005 14:30:00 16.7 1.7 20.6 11.5 16.8 1.9 21 11.5 354 5 353 305 -7.1 0 -6.7 -7.3 11/19/2005 14:40:00 16 1.9 19.5 10.7 16.1 2 19.5 11.5 356 5 357 305 -7.2 0.2 -6.7 -7.5 11/19/2005 14:50:00 16.6 1.4 19.9 13.3 16.8 1.4 20.2 13.3 354 5 353 305 -7.2 0 -6.9 -7.5 11/19/2005 15:00:00 16.2 1.1 18.7 13 16.3 1.2 19.1 13 359 6 354 305 -7.2 0.1 -6.9 -7.7 11/19/2005 15:10:00 16.9 1.5 20.2 12.2 16.9 1.5 20.2 12.6 356 6 353 305 -7.4 0 -7.1 -7.7 11/19/2005 15:20:00 16.2 1.5 19.9 12.6 16.2 1.5 19.9 12.2 356 6 357 305 -7.3 0 -6.9 -7.7 11/19/2005 15:30:00 16.6 1.2 19.5 13 16.6 1.3 20.2 12.6 0 6 359 305 -7.4 0.1 -7.1 -7.7 11/19/2005 15:40:00 15.7 1.7 20.2 11.1 15.6 1.8 20.2 11.1 359 6 356 305 -7.4 0.1 -7.1 -7.7 11/19/2005 15:50:00 16.5 1.3 20.2 12.6 16.5 1.4 20.2 13 356 4 356 305 -7.3 0 -7.1 -7.5 11/19/2005 16:00:00 16.5 1.3 19.9 13 16.6 1.4 19.5 12.2 355 5 349 305 -7.4 0.2 -6.9 -7.7 11/19/2005 16:10:00 16.4 1.3 19.1 12.2 16.5 1.4 19.5 12.2 351 5 353 305 -7.4 0 -7.1 -7.7 11/19/2005 16:20:00 15.4 1.5 19.1 12.2 15.4 1.6 19.5 11.8 358 5 1 305 -7.1 0 -6.9 -7.3 11/19/2005 16:30:00 16.7 1.5 19.5 12.6 16.8 1.5 19.9 12.6 354 6 358 305 -7.4 0.1 -6.9 -7.7 11/19/2005 16:40:00 16.6 1.4 19.1 11.8 16.7 1.5 19.5 12.2 352 5 349 305 -7.5 0 -7.3 -7.7 11/19/2005 16:50:00 16.7 1.2 19.1 13 16.7 1.3 19.5 12.2 355 5 348 305 -7.5 0.1 -7.3 -7.7 11/19/2005 17:00:00 16.4 1.2 18.7 13 16.5 1.4 19.9 13 353 6 359 305 -7.4 0.1 -6.9 -7.7 11/19/2005 17:10:00 16 1.7 22.1 11.1 16 1.7 21 11.1 354 6 7 305 -7.4 0 -6.9 -7.7 11/19/2005 17:20:00 16.3 1.2 20.2 13.3 16.4 1.3 19.9 12.6 353 4 357 305 -7.4 0.1 -6.9 -7.7 11/19/2005 17:30:00 16.6 1.2 19.1 13 16.6 1.3 19.1 13 354 4 350 305 -7.4 0 -6.9 -7.7 11/19/2005 17:40:00 15.6 1.3 18.7 12.2 15.7 1.4 19.1 11.8 358 5 358 305 -7.4 0.1 -6.9 -7.7 11/19/2005 17:50:00 16 1.5 19.5 11.8 15.9 1.6 18.7 10.7 356 5 351 305 -7.3 0.1 -6.9 -7.7 11/19/2005 18:00:00 15.8 1.2 18.7 12.2 16 1.3 19.5 11.8 355 5 347 305 -7.4 0.1 -6.9 -7.7 11/19/2005 18:10:00 15.4 1.5 18.7 11.1 15.5 1.5 19.5 11.1 358 5 349 305 -7.5 0.1 -7.1 -7.7 11/19/2005 18:20:00 15.6 1.2 18.7 12.6 15.6 1.3 18.3 12.2 0 6 359 305 -7.5 0.1 -7.1 -7.7 11/19/2005 18:30:00 16.3 1.1 19.1 13 16.4 1.2 19.1 11.8 4 6 2 305 -7.5 0.1 -7.1 -7.7 11/19/2005 18:40:00 15.5 1.2 18.3 12.2 15.6 1.1 18.7 12.2 1 5 351 305 -7.4 0 -7.1 -7.7 11/19/2005 18:50:00 15.6 1.6 19.1 10.7 15.6 1.7 19.5 11.5 1 5 4 305 -7.5 0.1 -7.1 -7.7 11/19/2005 19:00:00 14.9 1.4 17.6 11.1 14.8 1.5 18.3 10.7 4 5 0 305 -7.4 0.2 -6.9 -7.7 11/19/2005 19:10:00 15.8 1.5 18.7 11.5 15.6 1.5 18.7 11.5 13 7 13 305 -7.3 0 -6.9 -7.7 11/19/2005 19:20:00 15.5 1.4 19.1 12.2 15.4 1.4 19.1 12.2 12 6 25 305 -7.2 0 -6.9 -7.5 11/19/2005 19:30:00 15.5 1.3 18.3 12.2 15.4 1.4 18.7 11.8 13 6 10 305 -7.3 0.1 -6.9 -7.7 11/19/2005 19:40:00 15.2 1.5 19.1 11.8 15.1 1.5 18.7 11.5 13 6 24 305 -7.3 0 -7.1 -7.7 11/19/2005 19:50:00 16 1 19.1 13 16 1 18.7 13 10 5 16 305 -7.4 0 -7.1 -7.5 11/19/2005 20:00:00 15.3 1.5 20.2 12.2 15.3 1.5 19.9 12.2 12 6 13 305 -7.3 0.1 -6.9 -7.7 11/19/2005 20:10:00 15.2 1.1 17.9 11.5 15.1 1.2 17.6 11.8 8 6 11 305 -7.4 0 -6.9 -7.5 11/19/2005 20:20:00 14.5 1.1 17.2 11.1 14.6 1.2 17.2 11.5 1 4 4 305 -7.5 0.2 -7.1 -7.9 11/19/2005 20:30:00 14.4 1.4 17.6 11.1 14.4 1.4 17.6 11.1 6 5 5 305 -7.7 0 -7.3 -7.9 11/19/2005 20:40:00 14.8 1.6 18.7 10.7 14.7 1.6 19.1 10.7 7 8 356 305 -7.6 0.1 -7.3 -7.9 11/19/2005 20:50:00 15.7 1.3 18.7 12.2 15.6 1.2 18.3 11.5 17 5 20 305 -7.6 0.1 -7.3 -7.9 11/19/2005 21:00:00 14.9 1.4 17.6 11.1 14.7 1.5 17.9 11.1 16 6 25 305 -7.5 0.1 -7.1 -7.7 11/19/2005 21:10:00 14.6 1.1 17.2 12.2 14.5 1.1 17.2 11.8 15 5 11 305 -7.5 0.1 -7.1 -7.7 11/19/2005 21:20:00 14.4 1.1 17.9 11.5 14.4 1.1 17.9 11.5 14 6 19 305 -7.9 0.1 -7.5 -8.2 11/19/2005 21:30:00 14.9 1.5 18.3 11.5 15 1.5 18.7 11.1 6 8 15 305 -7.7 0 -7.3 -7.9 11/19/2005 21:40:00 15.9 1.1 18.7 12.6 15.8 1.1 18.7 13 16 6 11 305 -7.6 0.1 -7.3 -7.9 11/19/2005 21:50:00 14.5 1 17.2 11.5 14.5 1.1 17.2 11.5 13 7 16 305 -7.6 0.1 -7.1 -7.9 11/19/2005 22:00:00 15.3 1.3 18.7 12.2 15.3 1.3 18.7 12.2 13 6 11 305 -7.6 0 -7.1 -7.9 11/19/2005 22:10:00 15.7 1.1 17.9 12.6 15.6 1.1 18.3 12.6 17 5 24 305 -7.6 0 -7.1 -7.9 11/19/2005 22:20:00 15.1 1.3 18.7 12.2 15 1.3 19.1 12.2 13 6 15 305 -7.6 0.1 -7.1 -7.9 11/19/2005 22:30:00 14.1 1.2 16.8 10.7 14.1 1.2 16.8 10.7 14 5 11 305 -7.7 0 -7.3 -7.9 11/19/2005 22:40:00 15.3 1.3 17.9 11.8 15.2 1.3 18.3 11.5 12 5 12 305 -7.9 0.2 -7.3 -8.2 11/19/2005 22:50:00 15.1 1.4 19.5 11.8 15 1.4 19.9 11.8 13 5 15 305 -7.8 0.1 -7.3 -8.2 11/19/2005 23:00:00 14.2 1.2 17.2 11.1 14.2 1.3 16.8 9.9 11 6 18 305 -7.8 0.1 -7.3 -8.2 11/19/2005 23:10:00 14 1.3 16.8 10.3 14 1.3 16.4 9.9 11 6 6 305 -8 0.2 -7.3 -8.4 11/19/2005 23:20:00 13.1 1 16.1 10.3 13.3 1.1 16.1 9.9 3 4 4 305 -7.9 0.2 -7.5 -8.4 11/19/2005 23:30:00 13.6 1.2 16.1 9.9 13.6 1.3 16.4 10.3 4 5 2 305 -7.7 0.1 -7.3 -8.2 11/19/2005 23:40:00 14.5 1.6 17.6 9.5 14.5 1.6 17.9 9.5 8 6 14 305 -7.8 0.1 -7.3 -8.2 11/19/2005 23:50:00 13.2 1.8 17.2 9.5 13.2 1.8 16.8 9.1 6 6 11 305 -7.7 0 -7.3 -7.9 11/20/2005 00:00:00 13.9 1.3 17.2 10.3 14 1.3 17.6 10.7 6 8 20 305 -7.8 0 -7.5 -7.9 11/20/2005 00:10:00 13.5 1.2 17.2 10.3 13.6 1.2 16.8 10.3 9 6 19 305 -7.8 0.1 -7.3 -8.2 11/20/2005 00:20:00 14.1 1.2 16.8 10.3 14.1 1.2 16.8 10.3 9 5 21 305 -7.8 0 -7.3 -8.2 11/20/2005 00:30:00 13.8 1.5 17.2 9.5 13.8 1.6 17.2 9.9 8 5 3 305 -7.7 0 -7.3 -7.9 11/20/2005 00:40:00 14.6 1.2 17.2 11.8 14.7 1.2 17.9 11.5 8 4 5 305 -7.8 0 -7.5 -8.2 11/20/2005 00:50:00 14.4 1.2 19.1 10.7 14.5 1.3 19.9 10.7 5 7 357 305 -7.9 0.1 -7.3 -8.2 11/20/2005 01:00:00 14.3 1.7 18.3 10.7 14.4 1.6 18.3 10.7 11 6 21 305 -8 0.1 -7.7 -8.4 11/20/2005 01:10:00 14.7 1.5 21 11.1 14.6 1.5 20.6 10.7 11 7 17 305 -8 0.1 -7.5 -8.4 11/20/2005 01:20:00 14.8 1.1 17.6 11.8 14.9 1.2 17.9 11.5 8 6 3 305 -7.9 0.1 -7.7 -8.2 11/20/2005 01:30:00 13.3 1.2 16.4 10.7 13.3 1.2 16.8 9.9 7 6 10 305 -8.1 0.1 -7.7 -8.4 11/20/2005 01:40:00 14.2 1.2 16.8 11.1 14.2 1.3 17.2 10.7 3 10 0 305 -8.2 0.1 -7.7 -8.4 11/20/2005 01:50:00 14 1.2 17.6 10.7 14.1 1.2 17.9 10.3 10 7 18 305 -8 0.1 -7.7 -8.4 11/20/2005 02:00:00 15 1.5 18.3 11.5 14.9 1.5 18.3 11.5 15 5 22 305 -8 0.1 -7.7 -8.2 11/20/2005 02:10:00 14.4 1.2 17.6 10.7 14.4 1.2 17.6 11.8 10 5 13 305 -7.9 0 -7.5 -8.2 11/20/2005 02:20:00 13 1.1 16.4 9.5 13.1 1.1 16.1 9.9 2 9 1 305 -7.9 0.2 -7.5 -8.2 11/20/2005 02:30:00 13.6 1.3 16.8 10.7 13.6 1.5 17.2 9.9 11 7 10 305 -8.1 0.1 -7.7 -8.4 11/20/2005 02:40:00 14.8 1.2 17.6 11.5 15 1.2 17.9 11.5 4 6 4 305 -8 0.1 -7.5 -8.2 11/20/2005 02:50:00 15.1 1.2 18.3 12.2 15.1 1.2 18.3 11.8 12 6 22 305 -8 0.1 -7.5 -8.4 11/20/2005 03:00:00 14.1 1.3 18.3 10.7 14.3 1.2 18.3 10.7 7 6 16 305 -7.9 0.1 -7.7 -8.2 11/20/2005 03:10:00 14.8 0.9 17.2 12.6 14.7 1 17.9 11.8 10 6 24 305 -7.9 0.1 -7.5 -8.2 11/20/2005 03:20:00 15.1 1.1 17.6 11.8 15 1.1 17.2 11.8 15 5 20 305 -8 0.1 -7.7 -8.2 11/20/2005 03:30:00 14.3 1.4 17.2 10.3 14.3 1.4 17.6 9.9 12 6 12 305 -8.2 0 -7.7 -8.4 11/20/2005 03:40:00 15.3 1.1 17.9 11.8 15.2 1.2 17.9 11.8 9 5 22 305 -8.1 0.1 -7.7 -8.2 11/20/2005 03:50:00 14.6 1.1 17.9 12.2 14.7 1.1 17.9 11.8 10 5 15 305 -8.2 0 -7.7 -8.2 11/20/2005 04:00:00 14.9 1 17.2 11.5 15.1 1 17.6 11.5 3 5 11 305 -8.2 0 -7.7 -8.4 11/20/2005 04:10:00 14.6 1.1 17.2 11.8 14.7 1.2 17.6 11.8 1 8 350 305 -8.2 0 -7.7 -8.4 11/20/2005 04:20:00 15.3 1.4 18.7 11.5 15.4 1.5 18.7 11.8 7 6 12 305 -8.2 0 -7.7 -8.2 11/20/2005 04:30:00 14.7 1.4 19.1 11.5 14.8 1.4 19.5 11.5 7 7 8 305 -8.2 0 -7.7 -8.4 11/20/2005 04:40:00 14 1.5 18.3 11.1 14.2 1.6 17.9 10.7 7 5 9 305 -8.2 0 -7.7 -8.4 11/20/2005 04:50:00 14.5 1.3 17.6 11.1 14.7 1.3 17.9 11.8 7 5 10 305 -8.1 0.1 -7.5 -8.4 11/20/2005 05:00:00 14.9 1.2 18.3 11.1 14.9 1.2 18.3 11.5 5 7 2 305 -8.2 0 -7.7 -8.4 11/20/2005 05:10:00 14.7 1.5 18.7 11.5 14.8 1.5 18.3 12.2 9 6 17 305 -8.2 0 -7.7 -8.4 11/20/2005 05:20:00 14.3 1.3 17.9 11.5 14.4 1.3 17.6 11.5 7 9 15 305 -8.2 0 -7.7 -8.4 11/20/2005 05:30:00 14.5 1.2 17.6 11.5 14.5 1.1 17.9 11.5 354 7 0 305 -8.4 0.1 -7.9 -8.8 11/20/2005 05:40:00 14.3 1.4 17.2 11.1 14.5 1.4 17.6 10.7 3 9 19 305 -8.4 0.1 -7.9 -8.8 11/20/2005 05:50:00 15.6 1.1 17.9 12.6 15.7 1.1 17.9 13 8 5 10 305 -8.4 0 -7.9 -8.6 11/20/2005 06:00:00 14.7 1.4 18.3 11.1 14.8 1.4 18.7 11.1 9 5 1 305 -8.3 0 -7.7 -8.4 11/20/2005 06:10:00 14.1 1.3 17.2 11.1 14.2 1.2 17.2 11.5 3 6 9 305 -8.2 0 -7.7 -8.4 11/20/2005 06:20:00 15.4 1.2 19.1 12.6 15.4 1.1 18.7 12.2 8 5 7 305 -8.2 0 -7.7 -8.4 11/20/2005 06:30:00 15.5 1.2 18.3 12.6 15.5 1.2 18.7 12.2 8 5 16 305 -8.2 0 -7.7 -8.4 11/20/2005 06:40:00 14.8 1.3 16.8 11.8 14.9 1.3 17.6 11.5 5 5 10 305 -8.3 0 -7.7 -8.4 11/20/2005 06:50:00 15.3 1.5 18.7 10.7 15.4 1.5 19.5 11.8 2 6 6 305 -8.1 0.1 -7.7 -8.4 11/20/2005 07:00:00 15.7 1.3 18.7 11.8 15.8 1.3 19.1 11.1 2 5 356 305 -8.1 0.1 -7.7 -8.4 11/20/2005 07:10:00 15.7 1.5 19.5 11.8 15.9 1.6 19.9 11.1 359 5 1 305 -8 0.1 -7.5 -8.2 11/20/2005 07:20:00 15.3 1.3 17.9 12.2 15.5 1.3 18.3 11.1 359 7 5 305 -8 0.1 -7.7 -8.2 11/20/2005 07:30:00 15.9 1.6 20.6 12.2 16 1.7 21 12.2 3 6 8 305 -7.8 0.1 -7.3 -8.2 11/20/2005 07:40:00 15.6 1.3 18.7 11.8 15.7 1.4 18.7 11.5 0 7 3 305 -8 0.1 -7.7 -8.4 11/20/2005 07:50:00 15.2 1.3 18.7 11.8 15.2 1.3 18.7 12.2 7 5 7 305 -8 0.1 -7.3 -8.4 11/20/2005 08:00:00 13.7 1.1 16.8 11.1 13.8 1.2 16.8 10.3 1 7 359 305 -7.9 0.2 -7.3 -8.2 11/20/2005 08:10:00 15.2 1.6 19.5 11.5 15.3 1.5 19.1 11.8 3 5 5 305 -7.8 0.1 -7.3 -8.2 11/20/2005 08:20:00 14.7 1.3 17.2 11.5 14.8 1.3 17.6 11.1 5 6 0 305 -7.8 0 -7.3 -8.2 11/20/2005 08:30:00 14.6 1.3 17.6 11.1 14.8 1.3 18.3 11.5 1 5 2 305 -7.8 0 -7.3 -7.9 11/20/2005 08:40:00 15.1 1.5 18.3 10.3 15.1 1.4 17.9 10.3 2 5 2 305 -7.7 0 -7.3 -7.9 11/20/2005 08:50:00 14.4 1.4 18.3 11.8 14.4 1.3 17.6 11.1 5 7 4 305 -7.7 0 -7.1 -7.9 11/20/2005 09:00:00 15.4 1.3 19.1 12.2 15.5 1.4 19.9 12.2 4 5 11 305 -7.6 0 -7.3 -7.7 11/20/2005 09:10:00 15.6 1.5 19.5 12.2 15.7 1.3 19.9 12.6 4 5 7 305 -7.6 0 -7.1 -7.7 11/20/2005 09:20:00 15.3 1.5 18.7 11.5 15.4 1.5 19.1 11.5 4 6 0 305 -7.6 0.1 -7.1 -7.9 11/20/2005 09:30:00 16.2 1.4 19.9 12.6 16.3 1.5 20.2 12.2 5 4 7 305 -7.6 0.1 -7.1 -7.7 11/20/2005 09:40:00 15.6 1.5 19.9 11.8 15.5 1.5 20.6 11.5 3 5 8 305 -7.6 0.1 -7.1 -7.7 11/20/2005 09:50:00 15.5 1.3 19.5 12.2 15.6 1.5 20.2 12.2 2 6 355 305 -7.6 0 -7.1 -7.7 11/20/2005 10:00:00 15.6 1.2 19.1 12.6 15.7 1.3 18.7 12.6 8 4 11 305 -7.6 0 -7.1 -7.7 11/20/2005 10:10:00 15.5 1.2 18.3 11.8 15.5 1.3 18.3 11.5 9 5 9 305 -7.5 0.1 -7.1 -7.7 11/20/2005 10:20:00 15.3 1.2 17.6 12.6 15.4 1.2 17.9 12.2 5 5 6 305 -7.5 0.1 -7.1 -7.7 11/20/2005 10:30:00 16.3 1.2 19.5 13 16.3 1.3 19.9 13 5 5 357 305 -7.5 0.1 -7.1 -7.7 11/20/2005 10:40:00 15.7 1.4 18.7 12.6 15.8 1.5 19.5 11.8 3 6 11 305 -7.4 0 -6.9 -7.7 11/20/2005 10:50:00 14.7 1.1 17.6 11.5 14.9 1.2 17.6 11.8 5 4 5 305 -7.5 0.1 -6.9 -7.7 11/20/2005 11:00:00 15.2 1.1 17.9 12.2 15.3 1.1 18.3 12.6 3 5 4 305 -7.4 0.1 -6.9 -7.7 11/20/2005 11:10:00 15.8 1.2 18.3 11.8 15.9 1.3 19.1 11.5 359 4 358 305 -7.4 0 -6.9 -7.5 11/20/2005 11:20:00 15.4 1.2 19.5 12.2 15.5 1.3 19.5 11.8 2 5 3 305 -7.3 0 -7.1 -7.7 11/20/2005 11:30:00 15.4 1.3 19.1 11.5 15.6 1.3 19.5 11.8 0 5 357 305 -7.2 0 -6.7 -7.5 11/20/2005 11:40:00 16.3 1.6 19.5 12.6 16.4 1.6 20.2 11.8 1 4 357 305 -7.2 0 -6.9 -7.7 11/20/2005 11:50:00 16.6 1.3 20.2 13 16.6 1.3 19.9 13.3 8 6 12 305 -7.7 0.3 -6.9 -8.2 11/20/2005 12:00:00 15.7 1.3 18.7 12.6 15.8 1.4 19.5 12.2 5 5 4 305 -7.6 0.1 -7.1 -7.9 11/20/2005 12:10:00 15.4 1.5 18.3 10.7 15.5 1.5 18.3 11.1 11 6 6 305 -7.5 0.1 -7.1 -7.7 11/20/2005 12:20:00 15.7 1.1 18.3 12.6 15.7 1.1 18.3 13 11 5 11 305 -7.5 0.2 -6.9 -7.9 11/20/2005 12:30:00 15.7 1.5 18.3 11.8 15.7 1.6 18.7 12.6 15 5 12 305 -7.4 0.1 -6.9 -7.7 11/20/2005 12:40:00 14.9 1.3 17.6 11.5 15 1.3 17.6 11.5 11 4 16 305 -7.5 0.1 -7.1 -7.7 11/20/2005 12:50:00 15.8 1.1 18.3 12.6 15.9 1.2 18.3 11.8 7 5 6 305 -7.3 0.1 -6.9 -7.7 11/20/2005 13:00:00 16.2 1.1 19.1 13 16.2 1.3 19.5 12.6 9 6 6 305 -7.4 0 -6.9 -7.7 11/20/2005 13:10:00 16.2 1.5 19.1 12.6 16.2 1.5 19.5 12.2 7 4 11 305 -7.6 0.2 -7.1 -7.9 11/20/2005 13:20:00 15 1.3 18.7 12.2 15.1 1.4 18.7 11.8 7 5 359 305 -7.8 0.2 -7.1 -8.2 11/20/2005 13:30:00 14.8 1.1 17.6 11.8 14.9 1.1 17.6 12.2 9 5 8 305 -7.5 0.1 -7.1 -7.7 11/20/2005 13:40:00 16.2 1.2 19.1 13 16.1 1.3 19.5 13 8 6 14 305 -7.5 0.1 -6.9 -7.7 11/20/2005 13:50:00 14.2 1.4 17.9 10.7 14.2 1.5 17.9 11.5 16 4 19 305 -7.8 0.2 -7.1 -8.2 11/20/2005 14:00:00 15.7 1.5 19.5 12.2 15.8 1.6 19.5 11.1 8 7 16 305 -7.7 0.2 -7.3 -8.4 11/20/2005 14:10:00 15.7 1.1 18.3 12.6 15.8 1.2 18.7 13 4 7 3 305 -8.2 0.2 -7.3 -8.4 11/20/2005 14:20:00 14.5 1.2 17.2 10.7 14.7 1.2 17.6 11.5 9 4 3 305 -7.5 0.1 -7.1 -7.7 11/20/2005 14:30:00 14.9 1 17.6 11.1 15.1 1.1 17.6 11.8 9 4 11 305 -7.4 0.1 -7.1 -7.7 11/20/2005 14:40:00 14.4 1 16.8 11.5 14.4 1.1 16.4 11.5 13 5 15 305 -7.9 0.2 -7.1 -8.2 11/20/2005 14:50:00 15.3 1.3 18.7 10.3 15.5 1.3 18.7 11.1 2 9 12 305 -7.8 0.1 -7.3 -8.2 11/20/2005 15:00:00 15.1 1.5 18.7 11.5 15.3 1.7 19.1 11.8 357 8 343 305 -7.9 0.2 -7.3 -8.4 11/20/2005 15:10:00 15.7 1.6 18.7 11.5 16 1.7 19.5 11.8 348 5 345 305 -7.8 0 -7.3 -8.2 11/20/2005 15:20:00 16 1.3 19.5 12.6 16.1 1.5 19.9 12.2 353 5 348 305 -7.8 0.1 -7.3 -8.2 11/20/2005 15:30:00 15.6 1.3 18.3 12.2 15.7 1.3 19.1 12.2 352 5 346 305 -8.1 0.1 -7.7 -8.4 11/20/2005 15:40:00 15.4 1.3 18.3 11.5 15.5 1.5 19.1 11.8 357 6 355 305 -8 0.1 -7.5 -8.2 11/20/2005 15:50:00 15.4 1.9 19.5 8.4 15.4 2 20.2 8.8 358 10 350 305 -8.2 0.1 -7.7 -8.4 11/20/2005 16:00:00 16.8 1.3 19.9 11.8 16.9 1.4 19.9 12.6 349 4 354 305 -8.4 0 -7.9 -8.6 11/20/2005 16:10:00 16.9 1.3 19.5 13.3 17 1.4 19.9 12.6 348 6 353 305 -8.3 0.1 -7.7 -8.6 11/20/2005 16:20:00 16.3 1.5 20.2 12.2 16.5 1.5 20.6 12.6 348 5 347 305 -8.3 0.2 -7.7 -8.6 11/20/2005 16:30:00 17 1.4 20.2 13 17.2 1.5 20.6 13.3 349 4 352 305 -8.3 0 -7.9 -8.6 11/20/2005 16:40:00 17 1.3 20.6 13.7 17.2 1.4 21.4 13.3 346 5 347 305 -8.4 0 -7.9 -8.6 11/20/2005 16:50:00 16.5 1.3 19.5 13 16.8 1.3 19.9 13.3 345 5 345 305 -8.4 0 -8.2 -8.6 11/20/2005 17:00:00 17 1.2 19.5 13.3 17.2 1.2 19.5 14.1 347 4 343 305 -8.3 0 -7.9 -8.6 11/20/2005 17:10:00 16.6 1.1 19.1 13.3 16.7 1.2 19.9 13 349 4 350 305 -8.3 0 -7.9 -8.6 11/20/2005 17:20:00 16.8 1.3 19.9 13.3 17 1.4 20.2 13 348 5 350 305 -8.4 0 -7.9 -8.8 11/20/2005 17:30:00 17 1.1 19.1 13 17.2 1.2 20.2 13.3 346 5 349 305 -8.4 0.1 -7.9 -8.8 11/20/2005 17:40:00 16.2 1.2 19.5 12.6 16.5 1.3 19.5 12.2 345 6 340 305 -8.5 0.1 -8.2 -8.8 11/20/2005 17:50:00 16.8 1.6 21.4 13.3 16.9 1.6 21.4 13 347 4 344 305 -8.4 0 -7.9 -8.6 11/20/2005 18:00:00 16.7 1.2 19.9 13.3 16.9 1.2 20.6 13.7 347 4 347 305 -8.3 0 -7.9 -8.4 11/20/2005 18:10:00 17 1.1 19.5 13.3 17.2 1.2 20.2 14.1 348 4 344 305 -8.4 0 -7.9 -8.6 11/20/2005 18:20:00 16 1.4 19.5 11.8 16.2 1.4 19.5 12.2 348 5 342 305 -8.3 0 -7.9 -8.4 11/20/2005 18:30:00 16.1 1.4 19.1 12.2 16.4 1.5 19.9 12.6 347 4 348 305 -8.3 0 -7.7 -8.4 11/20/2005 18:40:00 16.5 1.2 19.1 12.6 16.7 1.2 19.9 13 346 4 350 305 -8.3 0 -7.9 -8.6 11/20/2005 18:50:00 17 1.1 19.1 14.5 17.2 1.1 19.5 14.5 346 4 349 305 -8.4 0.1 -7.9 -8.6 11/20/2005 19:00:00 16.4 0.9 18.3 13.3 16.6 1 18.7 14.5 352 4 348 305 -8.3 0 -7.9 -8.6 11/20/2005 19:10:00 15.9 1.2 19.1 12.6 16.1 1.2 19.1 13 350 5 354 305 -8.2 0 -7.7 -8.4 11/20/2005 19:20:00 16.2 1.4 19.1 13 16.5 1.5 19.9 12.6 354 4 356 305 -8.1 0.1 -7.7 -8.4 11/20/2005 19:30:00 15.7 1.3 18.7 12.2 16 1.4 19.5 11.5 352 5 353 305 -8.2 0 -7.7 -8.4 11/20/2005 19:40:00 15.5 1 17.9 12.2 15.7 1 17.9 12.6 356 4 2 305 -8.2 0 -7.7 -8.4 11/20/2005 19:50:00 15.5 1.1 17.6 11.8 15.8 1.2 17.9 12.2 354 5 357 305 -8.2 0 -7.7 -8.4 11/20/2005 20:00:00 15.1 1 17.6 12.2 15.4 1.1 17.9 13 349 4 351 305 -8.2 0 -7.7 -8.4 11/20/2005 20:10:00 15.2 1.2 17.9 12.2 15.4 1.3 18.3 12.2 348 5 348 305 -8 0.1 -7.7 -8.2 11/20/2005 20:20:00 16.1 0.9 18.3 13.7 16.3 1.1 18.7 13.3 348 3 343 305 -8.2 0 -7.7 -8.4 11/20/2005 20:30:00 15.6 1.1 18.3 12.2 15.8 1.3 18.7 12.2 348 4 346 305 -8 0.1 -7.7 -8.2 11/20/2005 20:40:00 15.9 1.2 18.3 11.5 16.2 1.2 18.7 11.8 349 5 347 305 -8.2 0.1 -7.5 -8.4 11/20/2005 20:50:00 15.4 1.2 18.3 12.2 15.6 1.3 18.7 11.5 349 4 348 305 -8.2 0.1 -7.7 -8.6 11/20/2005 21:00:00 14.7 1 16.8 11.5 14.9 1 17.2 12.2 352 4 347 305 -8.2 0 -7.7 -8.4 11/20/2005 21:10:00 14.6 1.1 17.6 11.8 14.8 1.2 18.3 11.5 351 4 350 305 -8.2 0 -7.7 -8.4 11/20/2005 21:20:00 15.2 1.1 17.2 12.2 15.4 1.1 17.6 11.5 345 5 351 305 -8.1 0.1 -7.5 -8.4 11/20/2005 21:30:00 14.7 1.5 17.9 10.3 14.9 1.6 18.3 10.7 353 12 340 305 -7.7 0.2 -7.1 -8.2 11/20/2005 21:40:00 13 1.5 16.4 8.8 13 1.5 16.8 9.5 26 12 14 305 -7.5 0.2 -6.9 -7.9 11/20/2005 21:50:00 12.9 1.7 16.8 8 13 1.7 17.2 8 10 10 353 305 -7.2 0.1 -6.7 -7.5 11/20/2005 22:00:00 15.4 1 17.2 12.6 15.7 1 17.6 12.6 355 4 358 305 -7.6 0 -7.1 -7.7 11/20/2005 22:10:00 14.6 1.4 18.3 10.7 14.7 1.5 18.3 11.5 11 15 355 305 -7.6 0.1 -7.1 -7.9 11/20/2005 22:20:00 11.6 1 14.1 8.8 11.6 1 14.1 9.1 27 5 24 305 -8 0.1 -7.5 -8.2 11/20/2005 22:30:00 11.8 0.9 14.5 9.1 11.9 0.9 14.5 9.5 16 4 9 305 -7.8 0.1 -7.3 -7.9 11/20/2005 22:40:00 15.5 1.4 17.9 11.8 15.6 1.5 18.7 11.8 352 8 353 305 -7.6 0 -7.1 -7.9 11/20/2005 22:50:00 15.4 1 17.6 12.2 15.7 1.2 18.7 12.2 345 5 345 305 -7.7 0 -7.3 -7.9 11/20/2005 23:00:00 15.2 1.6 22.1 11.5 15.5 1.6 22.9 11.5 351 9 1 305 -7.7 0 -7.3 -7.9 11/20/2005 23:10:00 8.8 1.5 11.5 3 8.7 1.5 11.5 3.4 24 10 29 305 -8.1 0.1 -7.5 -8.4 11/20/2005 23:20:00 8.9 1.2 11.5 4.9 8.9 1.2 11.5 4.9 18 8 4 305 -8.3 0 -7.7 -8.6 11/20/2005 23:30:00 9.9 1.7 14.1 7.2 9.8 1.8 14.5 7.2 16 7 11 305 -8.3 0.1 -7.9 -8.6 11/20/2005 23:40:00 13 1.5 15.6 9.9 12.9 1.5 16.1 9.1 28 7 22 305 -8 0.1 -7.5 -8.4 11/20/2005 23:50:00 11.3 1.1 14.5 9.1 11.2 1.2 14.1 8.8 30 7 23 305 -7.9 0 -7.7 -8.2 11/21/2005 00:00:00 11.3 1.6 14.5 7.6 11.3 1.7 14.9 7.6 19 8 17 305 -7.7 0.2 -6.9 -8.2 11/21/2005 00:10:00 13 0.8 14.9 11.1 13.1 0.8 14.9 11.1 12 7 31 305 -7.3 0 -6.9 -7.7 11/21/2005 00:20:00 13.5 1.3 17.2 11.1 13.6 1.4 17.2 11.1 13 11 11 305 -7.5 0.2 -6.9 -7.7 11/21/2005 00:30:00 14.7 1 17.2 12.6 14.7 1 17.9 12.2 9 4 5 305 -7.2 0 -6.9 -7.5 11/21/2005 00:40:00 13.7 1.2 16.8 10.3 13.7 1.2 16.8 10.3 20 10 7 305 -7.2 0 -6.7 -7.7 11/21/2005 00:50:00 12.1 0.9 14.5 10.3 12.2 0.9 14.5 10.3 21 11 17 305 -7.7 0.1 -7.1 -7.9 11/21/2005 01:00:00 10.4 0.8 12.2 8 10.4 0.8 12.2 8 20 12 11 305 -7.5 0.2 -6.9 -7.9 11/21/2005 01:10:00 10.4 0.8 12.6 8.4 10.4 0.9 12.6 8.4 36 6 35 305 -7.3 0 -6.9 -7.5 11/21/2005 01:20:00 10.4 1 12.6 7.2 10.5 1.1 13 7.6 38 6 39 305 -7.4 0 -6.9 -7.5 11/21/2005 01:30:00 11.3 0.8 13.7 8.8 11.4 0.8 13.3 9.1 41 6 34 305 -7.4 0 -6.9 -7.7 11/21/2005 01:40:00 11.9 1 14.1 9.5 11.9 1 14.1 9.5 37 5 39 305 -7.4 0.1 -6.9 -7.7 11/21/2005 01:50:00 10.6 1 13 7.6 10.6 1 13 8.4 31 7 32 305 -7.4 0 -6.9 -7.7 11/21/2005 02:00:00 11.4 1.1 14.1 9.1 11.4 1.1 14.1 9.1 29 7 26 305 -7.3 0 -6.9 -7.5 11/21/2005 02:10:00 11.5 0.9 13.3 8.8 11.5 0.9 13.3 8.4 32 6 40 305 -7.2 0 -6.9 -7.3 11/21/2005 02:20:00 11 1.1 13.7 8.8 11 1.2 13.3 8.4 28 5 27 305 -7.1 0 -6.7 -7.3 11/21/2005 02:30:00 11.6 0.8 13.3 9.5 11.6 0.9 13.7 9.1 25 4 30 305 -7.1 0 -6.7 -7.3 11/21/2005 02:40:00 13.7 1.4 16.8 10.3 13.8 1.5 16.8 10.3 9 9 19 305 -7.5 0.3 -6.9 -7.9 11/21/2005 02:50:00 12.9 1.1 15.6 9.1 12.9 1.1 15.3 9.5 22 5 29 305 -7.8 0.1 -7.3 -8.2 11/21/2005 03:00:00 11.7 1.5 15.3 8 11.8 1.5 14.9 8.4 22 13 35 305 -7.6 0.1 -7.1 -7.9 11/21/2005 03:10:00 11.6 0.9 14.1 9.5 11.7 1 14.5 9.5 34 6 37 305 -7.9 0.2 -7.3 -8.4 11/21/2005 03:20:00 9.9 0.8 11.8 8.4 10 0.8 12.2 8 14 4 14 305 -7.8 0.1 -7.3 -8.2 11/21/2005 03:30:00 11.3 1 13.3 8.4 11.2 1 13.3 8.4 24 6 24 305 -7.4 0.1 -7.1 -7.7 11/21/2005 03:40:00 11.1 0.6 13.3 9.5 11.2 0.7 13.3 9.1 21 5 25 305 -7.2 0 -7.1 -7.3 11/21/2005 03:50:00 10.9 1.2 14.1 8.8 11 1.3 14.5 8.8 14 11 6 305 -7 0.1 -6.9 -7.3 11/21/2005 04:00:00 12.4 1.6 16.4 9.5 12.6 1.6 16.8 9.9 5 4 13 305 -7.1 0 -6.9 -7.3 11/21/2005 04:10:00 12.4 1.5 15.3 9.1 12.4 1.5 15.6 8.8 14 5 8 305 -7.6 0 -7.1 -7.7 11/21/2005 04:20:00 14.5 1.2 18.7 11.1 14.7 1.2 19.1 11.5 8 6 5 305 -7.1 0.2 -6.7 -7.7 11/21/2005 04:30:00 15.3 0.9 17.2 12.6 15.5 0.9 17.9 11.8 4 4 5 305 -7 0 -6.7 -7.3 11/21/2005 04:40:00 15.3 1.3 18.3 11.8 15.5 1.3 18.7 11.8 3 5 8 305 -7 0.1 -6.7 -7.3 11/21/2005 04:50:00 15.7 1.1 18.3 12.6 15.8 1.2 18.7 12.6 3 4 3 305 -7 0 -6.7 -7.1 11/21/2005 05:00:00 15.7 1.2 18.7 12.6 15.8 1.2 18.7 12.6 3 5 0 305 -6.9 0 -6.7 -7.1 11/21/2005 05:10:00 15.6 1.5 18.7 11.1 15.7 1.4 18.3 11.1 6 5 11 305 -6.9 0.1 -6.4 -7.1 11/21/2005 05:20:00 15.6 1.4 19.5 12.2 15.8 1.4 20.2 12.2 359 5 358 305 -6.9 0 -6.7 -6.9 11/21/2005 05:30:00 16.2 1.4 18.7 11.8 16.3 1.5 19.5 11.1 2 4 359 305 -6.9 0.1 -6.7 -7.1 11/21/2005 05:40:00 16 1.2 18.7 12.2 16 1.3 19.1 13 7 5 12 305 -6.8 0 -6.4 -6.9 11/21/2005 05:50:00 16.3 1.2 19.1 13 16.4 1.3 19.1 12.6 2 5 0 305 -6.8 0.1 -6.2 -7.1 11/21/2005 06:00:00 16.6 1.2 19.5 13 16.7 1.2 19.5 13 5 5 9 305 -6.9 0.1 -6.4 -7.1 11/21/2005 06:10:00 17.2 1.1 19.5 14.1 17.2 1.2 20.2 14.1 6 4 4 305 -7 0.1 -6.7 -7.3 11/21/2005 06:20:00 16.9 1.2 19.9 14.1 16.9 1.3 20.2 13.3 7 5 6 305 -7.2 0.2 -6.7 -7.7 11/21/2005 06:30:00 14.6 1.5 18.3 10.7 14.7 1.5 18.7 11.5 356 6 353 305 -7.2 0.1 -6.7 -7.5 11/21/2005 06:40:00 16 1.3 19.5 12.6 16.3 1.3 19.1 13 351 4 351 305 -7.6 0.1 -7.1 -7.9 11/21/2005 06:50:00 16.6 1.3 19.5 13 16.8 1.3 19.9 13.3 353 5 346 305 -7.6 0.1 -7.1 -7.9 11/21/2005 07:00:00 16.5 1.3 19.9 13 16.7 1.3 19.9 12.6 354 4 346 305 -7.5 0.1 -6.9 -7.7 11/21/2005 07:10:00 16.3 1.3 19.9 13.3 16.5 1.4 20.2 13.3 355 4 355 305 -7.4 0.1 -6.9 -7.7 11/21/2005 07:20:00 16.6 1.3 19.5 13.3 16.7 1.3 20.2 13 4 7 10 305 -7.1 0.1 -6.7 -7.5 11/21/2005 07:30:00 16.7 1.3 20.6 13.3 16.9 1.3 19.9 13.3 4 6 11 305 -7.1 0 -6.7 -7.3 11/21/2005 07:40:00 16.3 1.5 19.9 12.6 16.5 1.5 20.6 13.3 0 4 1 305 -7.1 0.1 -6.7 -7.3 11/21/2005 07:50:00 17.1 1.4 20.6 13 17.2 1.5 20.6 13.3 357 5 355 305 -7.2 0 -6.7 -7.5 11/21/2005 08:00:00 17 1.2 20.2 13.7 17.1 1.3 21 13.3 359 5 355 305 -7.1 0 -6.7 -7.3 11/21/2005 08:10:00 16.8 1.5 19.9 12.6 16.9 1.5 20.6 12.6 3 5 356 305 -6.9 0.1 -6.7 -7.3 11/21/2005 08:20:00 17.1 1.3 19.5 13.3 17.3 1.4 20.6 12.6 1 5 2 305 -7.1 0 -6.9 -7.3 11/21/2005 08:30:00 16.7 1.5 19.5 12.6 16.8 1.4 19.9 13 359 5 356 305 -7.1 0 -6.9 -7.3 11/21/2005 08:40:00 16.9 1.2 19.9 14.1 17.2 1.3 20.2 13.3 1 5 357 305 -7.2 0 -6.9 -7.5 11/21/2005 08:50:00 17.9 1.3 21 13.7 17.9 1.3 21 14.1 0 5 359 305 -7.1 0 -6.9 -7.3 11/21/2005 09:00:00 17.5 1.2 19.9 13.3 17.6 1.3 20.2 13.7 1 4 359 305 -7.2 0 -6.9 -7.3 11/21/2005 09:10:00 17.6 1.3 21 14.1 17.7 1.5 21 13.7 1 5 359 305 -7.1 0 -6.9 -7.3 11/21/2005 09:20:00 16.6 1.2 19.1 12.2 16.8 1.3 19.5 12.2 2 5 359 305 -7.1 0 -6.9 -7.3 11/21/2005 09:30:00 16.9 1.2 19.5 13.7 16.9 1.2 19.5 13.7 4 4 11 305 -7 0.1 -6.7 -7.3 11/21/2005 09:40:00 16.7 1.4 19.9 13.3 16.8 1.5 19.9 13 1 5 0 305 -7 0 -6.9 -7.1 11/21/2005 09:50:00 16.5 1.4 19.9 13.3 16.6 1.5 20.2 12.6 1 4 1 305 -7 0.1 -6.7 -7.3 11/21/2005 10:00:00 16.1 1.3 18.3 12.6 16.3 1.4 19.1 12.2 6 4 9 305 -7 0.1 -6.7 -7.3 11/21/2005 10:10:00 16.5 1.4 19.9 13.3 16.6 1.5 19.9 13 1 5 4 305 -7 0 -6.7 -7.1 11/21/2005 10:20:00 16.6 1.2 19.9 13.3 16.7 1.2 19.9 13.3 2 5 4 305 -6.9 0 -6.4 -7.1 11/21/2005 10:30:00 16.5 1.3 20.2 12.6 16.5 1.3 19.5 13 3 5 0 305 -6.9 0 -6.4 -7.1 11/21/2005 10:40:00 17 1.4 21 13.3 17.1 1.5 21.4 13.3 2 6 10 305 -6.9 0.1 -6.2 -7.1 11/21/2005 10:50:00 16.8 1.5 19.9 13 17 1.6 20.6 13 0 5 357 305 -7 0.1 -6.7 -7.1 11/21/2005 11:00:00 17.1 1.2 19.9 14.1 17.3 1.2 20.2 14.1 1 5 356 305 -6.9 0.1 -6.7 -7.3 11/21/2005 11:10:00 16.4 1.2 19.5 13.3 16.5 1.3 19.9 13 359 5 3 305 -6.9 0.1 -6.7 -7.3 11/21/2005 11:20:00 16.5 1.2 19.1 13.3 16.7 1.2 19.5 13.3 356 5 353 305 -7 0.1 -6.7 -7.3 11/21/2005 11:30:00 17.1 1.2 20.2 12.6 17.3 1.3 20.6 13.7 355 5 355 305 -7.1 0.1 -6.7 -7.3 11/21/2005 11:40:00 17.5 1.3 20.6 14.1 17.5 1.4 21 14.1 355 4 356 305 -7.2 0 -6.9 -7.5 11/21/2005 11:50:00 17 1.2 19.5 13.3 17.2 1.2 19.9 12.6 352 5 355 305 -7.4 0.1 -6.9 -7.7 11/21/2005 12:00:00 16.3 1.3 19.5 13.3 16.5 1.3 19.5 13 353 5 359 305 -7.3 0 -6.9 -7.5 11/21/2005 12:10:00 16.9 1.2 20.2 13.7 17.2 1.3 20.2 13.7 355 3 358 305 -7.4 0.1 -6.9 -7.5 11/21/2005 12:20:00 16.4 1.3 20.2 13.3 16.6 1.4 19.9 12.6 355 4 352 305 -7.2 0 -6.9 -7.7 11/21/2005 12:30:00 16.3 1.5 19.5 11.8 16.4 1.6 20.2 12.2 354 5 343 305 -7.2 0 -6.7 -7.5 11/21/2005 12:40:00 17 1.2 19.5 14.5 17.2 1.2 20.2 14.1 352 4 357 305 -7.5 0.1 -7.3 -7.7 11/21/2005 12:50:00 16.4 1.4 19.5 11.8 16.7 1.4 19.9 12.6 351 4 341 305 -7.4 0.1 -7.1 -7.7 11/21/2005 13:00:00 16.4 1.2 18.7 12.6 16.6 1.2 18.7 12.6 351 4 352 305 -7.4 0 -7.1 -7.7 11/21/2005 13:10:00 16.5 1.3 19.5 13 16.7 1.4 19.9 13 352 4 353 305 -7.4 0 -7.1 -7.7 11/21/2005 13:20:00 16.3 1.4 20.2 11.8 16.5 1.5 19.9 12.6 352 5 345 305 -7.4 0 -7.1 -7.7 11/21/2005 13:30:00 16.1 1.2 19.5 13 16.3 1.2 19.5 13 355 5 351 305 -7.2 0 -7.1 -7.3 11/21/2005 13:40:00 16.6 1.4 19.9 13 16.9 1.4 20.2 13.3 354 3 353 305 -7.4 0 -7.1 -7.7 11/21/2005 13:50:00 15.6 1.3 18.3 11.8 15.9 1.3 18.7 13 352 5 347 305 -7.5 0.1 -7.1 -7.7 11/21/2005 14:00:00 15.4 1 17.9 12.2 15.6 1.1 18.3 12.2 352 4 352 305 -7.5 0.1 -7.1 -7.7 11/21/2005 14:10:00 15.1 1.3 17.6 11.5 15.5 1.3 18.3 11.8 350 5 351 305 -7.5 0.1 -7.3 -7.7 11/21/2005 14:20:00 15.1 1.2 17.9 11.8 15.3 1.2 17.9 12.2 351 5 352 305 -7.4 0.1 -7.1 -7.7 11/21/2005 14:30:00 15.1 1.2 17.6 10.3 15.3 1.2 17.9 10.7 357 6 351 305 -7.4 0.1 -7.1 -7.7 11/21/2005 14:40:00 14.7 1.1 17.2 11.8 14.9 1.2 17.6 11.5 0 5 1 305 -7.5 0 -7.3 -7.7 11/21/2005 14:50:00 15.8 1.2 18.3 12.2 16 1.2 19.1 12.6 355 4 354 305 -7.4 0.1 -7.1 -7.7 11/21/2005 15:00:00 15.3 1.1 17.6 12.6 15.6 1.2 18.3 12.2 355 5 350 305 -7.4 0.1 -6.9 -7.7 11/21/2005 15:10:00 15.5 1.2 18.3 11.8 15.7 1.3 18.7 12.2 355 5 352 305 -7.5 0.1 -7.1 -7.7 11/21/2005 15:20:00 15.4 1 17.6 12.2 15.7 1.2 18.3 12.6 351 4 354 305 -7.6 0 -7.1 -7.9 11/21/2005 15:30:00 15.4 1 17.6 12.6 15.5 1 17.9 12.2 353 4 353 305 -7.6 0 -7.1 -7.9 11/21/2005 15:40:00 15.3 1 17.2 11.8 15.5 1.1 17.6 11.8 353 5 353 305 -7.7 0 -7.3 -7.9 11/21/2005 15:50:00 15.7 1.2 17.6 12.6 16 1.2 17.9 11.5 354 4 355 305 -7.7 0.1 -7.3 -8.2 11/21/2005 16:00:00 14.4 1.3 17.9 10.7 14.7 1.3 17.9 10.7 354 6 355 305 -7.7 0.1 -7.1 -7.9 11/21/2005 16:10:00 14.8 1.3 17.6 11.5 15.1 1.4 18.7 11.1 352 5 346 305 -7.6 0.1 -7.1 -7.7 11/21/2005 16:20:00 14.1 1.1 16.1 10.7 14.3 1.2 16.8 11.1 350 5 348 305 -7.7 0 -7.3 -7.9 11/21/2005 16:30:00 14.6 0.9 16.8 11.8 14.9 1 17.6 12.2 354 5 353 305 -7.6 0.1 -7.1 -7.9 11/21/2005 16:40:00 15.2 1.3 17.9 11.8 15.5 1.3 18.3 12.2 352 5 341 305 -7.6 0.1 -7.1 -7.9 11/21/2005 16:50:00 15.1 1.5 18.7 9.9 15.3 1.6 18.7 11.1 350 7 350 305 -7.7 0 -7.3 -7.9 11/21/2005 17:00:00 13.8 0.9 16.1 11.5 14.1 1 16.4 11.5 355 5 357 305 -7.7 0 -7.3 -7.9 11/21/2005 17:10:00 14.9 1.1 17.6 12.2 15.1 1.2 17.9 12.2 357 6 354 305 -7.8 0 -7.7 -7.9 11/21/2005 17:20:00 14.5 1.1 17.2 11.8 14.7 1.2 17.2 11.5 355 4 351 305 -7.9 0.1 -7.7 -8.2 11/21/2005 17:30:00 14.4 1.2 17.6 11.5 14.6 1.3 17.9 11.5 352 4 356 305 -8 0.1 -7.7 -8.4 11/21/2005 17:40:00 13.9 1.1 17.2 11.1 14.2 1.1 17.6 11.8 353 5 1 305 -7.9 0.1 -7.5 -8.2 11/21/2005 17:50:00 14.1 1 16.4 11.5 14.3 1.1 16.8 11.1 354 6 357 305 -8.1 0.1 -7.7 -8.4 11/21/2005 18:00:00 14.1 1.1 16.8 11.5 14.4 1.1 16.8 11.5 359 5 0 305 -7.8 0 -7.5 -7.9 11/21/2005 18:10:00 13.9 1.1 16.8 11.1 14.1 1.2 16.8 11.1 0 6 4 305 -7.7 0 -7.3 -7.9 11/21/2005 18:20:00 13.9 1.1 16.8 11.1 14.1 1.1 16.8 11.1 359 5 359 305 -7.7 0 -7.7 -7.9 11/21/2005 18:30:00 14.1 1.1 17.6 11.5 14.4 1.1 17.2 11.8 0 4 357 305 -7.7 0 -7.5 -7.9 11/21/2005 18:40:00 14.2 1.2 17.6 11.1 14.4 1.3 18.3 11.1 1 5 359 305 -7.7 0 -7.5 -7.9 11/21/2005 18:50:00 13.1 1.1 15.3 9.9 13.3 1.1 16.1 9.9 9 5 16 305 -7.7 0 -7.3 -7.9 11/21/2005 19:00:00 12.9 1.1 16.1 9.9 13.1 1.1 16.1 9.9 353 5 351 305 -8 0.1 -7.7 -8.2 11/21/2005 19:10:00 13.9 0.9 16.1 11.5 14.1 1 16.4 10.7 357 6 0 305 -8.1 0.1 -7.7 -8.4 11/21/2005 19:20:00 13.8 1.2 16.8 10.7 14.1 1.3 16.4 10.7 355 4 358 305 -8.3 0 -7.9 -8.6 11/21/2005 19:30:00 13.7 1 15.6 11.1 14 1 16.4 11.1 355 4 357 305 -8.3 0 -7.9 -8.4 11/21/2005 19:40:00 13.5 1.1 16.4 10.3 13.8 1.1 17.2 11.1 354 5 357 305 -8.2 0.1 -7.7 -8.6 11/21/2005 19:50:00 13.8 1.1 15.6 11.1 14 1.1 16.8 10.7 355 5 349 305 -8.2 0 -7.7 -8.4 11/21/2005 20:00:00 14.1 1.1 16.4 11.1 14.4 1.1 16.8 11.1 357 5 4 305 -8.2 0 -7.7 -8.4 11/21/2005 20:10:00 13.5 1 15.6 10.7 13.9 1 16.1 10.7 355 5 359 305 -8.3 0 -7.7 -8.6 11/21/2005 20:20:00 13.7 1.1 16.1 10.7 14.1 1 16.1 11.1 354 5 355 305 -8.3 0 -7.7 -8.4 11/21/2005 20:30:00 13.1 1 15.3 10.7 13.4 1 16.1 10.3 352 6 355 305 -8.4 0.1 -7.9 -8.6 11/21/2005 20:40:00 13.5 1 15.6 10.3 13.8 1.1 16.4 10.3 353 5 353 305 -8.3 0 -7.7 -8.4 11/21/2005 20:50:00 13.9 1.1 17.6 11.1 14.1 1.2 17.2 10.7 356 5 355 305 -8.3 0 -7.7 -8.6 11/21/2005 21:00:00 13.9 1.4 16.8 10.7 14.1 1.5 17.2 10.7 356 4 357 305 -8.3 0.1 -7.7 -8.6 11/21/2005 21:10:00 13.4 1.1 15.6 10.7 13.7 1.2 16.4 10.3 358 4 355 305 -8.4 0 -7.9 -8.6 11/21/2005 21:20:00 14 1.3 17.2 10.3 14.1 1.3 17.2 10.7 2 5 12 305 -8.3 0.1 -7.7 -8.6 11/21/2005 21:30:00 12.5 0.8 14.9 10.3 12.7 0.9 15.3 9.9 4 6 356 305 -8.3 0 -7.9 -8.6 11/21/2005 21:40:00 13.7 1.2 17.2 10.7 13.9 1.2 17.2 10.7 359 6 355 305 -8.5 0 -8.2 -8.8 11/21/2005 21:50:00 12.8 1 15.6 10.3 13 1.1 15.6 10.7 3 4 0 305 -8.5 0.1 -8.2 -8.8 11/21/2005 22:00:00 13.3 1.2 16.1 10.3 13.6 1.1 16.1 10.3 2 6 358 305 -8.5 0.1 -8.2 -8.8 11/21/2005 22:10:00 12.7 1.3 16.1 9.9 13 1.4 16.4 9.5 3 6 357 305 -8.4 0 -8.2 -8.6 11/21/2005 22:20:00 12 1 14.5 9.5 12.2 1 14.5 9.9 3 6 3 305 -8.5 0.1 -8.2 -8.8 11/21/2005 22:30:00 12.4 1.3 14.9 8.8 12.6 1.3 15.6 8.8 2 5 2 305 -8.5 0 -8.2 -8.8 11/21/2005 22:40:00 12.3 1.2 16.1 6.5 12.6 1.2 16.1 8.4 4 7 1 305 -8.5 0 -8.2 -8.8 11/21/2005 22:50:00 12.4 1.1 14.5 9.9 12.7 1.2 14.9 9.9 2 5 8 305 -8.5 0 -8.2 -8.8 11/21/2005 23:00:00 12.4 1.1 14.9 9.5 12.6 1.2 15.6 9.5 2 5 1 305 -8.5 0.1 -8.2 -8.8 11/21/2005 23:10:00 11.7 1.1 14.9 8.8 11.9 1.2 14.9 8.4 4 6 0 305 -8.6 0 -8.4 -8.8 11/21/2005 23:20:00 12.9 1.3 16.8 9.5 13.1 1.3 17.9 9.5 0 6 354 305 -8.5 0.1 -8.4 -8.8 11/21/2005 23:30:00 12.2 1.3 14.9 9.1 12.5 1.4 15.6 8.8 359 6 352 305 -8.6 0 -8.4 -8.8 11/21/2005 23:40:00 12 0.9 14.1 9.5 12.3 0.9 14.9 9.9 1 5 5 305 -8.6 0.1 -8.4 -8.8 11/21/2005 23:50:00 12.1 1.3 15.6 9.1 12.4 1.3 16.1 9.5 358 5 352 305 -8.6 0 -8.4 -8.8 11/22/2005 00:00:00 12.6 1.3 15.6 9.5 12.9 1.2 16.1 10.3 0 5 9 305 -8.6 0.1 -8.2 -8.8 11/22/2005 00:10:00 11.8 1.3 14.9 9.1 12 1.3 15.6 9.5 0 6 7 305 -8.7 0.1 -8.2 -9 11/22/2005 00:20:00 11.9 1.2 14.9 9.1 12.1 1.2 15.3 9.1 2 5 3 305 -8.6 0.1 -7.9 -8.8 11/22/2005 00:30:00 11.6 1.1 14.5 9.1 11.9 1.2 14.9 8.4 0 6 0 305 -8.7 0 -8.2 -9 11/22/2005 00:40:00 12.5 1.7 16.1 9.1 12.8 1.7 16.8 8.8 1 6 8 305 -8.7 0 -8.4 -8.8 11/22/2005 00:50:00 11.7 1.3 14.9 9.1 11.9 1.3 15.3 9.1 2 6 356 305 -8.6 0.1 -8.2 -8.8 11/22/2005 01:00:00 12.5 1.3 16.4 9.1 12.7 1.4 16.4 9.1 4 5 12 305 -8.6 0.1 -8.2 -8.8 11/22/2005 01:10:00 12 1.1 14.9 9.5 12.1 1.1 15.3 8.4 9 6 359 305 -8.6 0.1 -8.2 -8.8 11/22/2005 01:20:00 11.9 1.4 15.6 9.1 12.1 1.5 16.4 9.1 9 6 2 305 -8.6 0.1 -8.2 -8.8 11/22/2005 01:30:00 11.6 1.2 14.5 8.8 11.9 1.2 15.3 9.5 3 6 354 305 -8.5 0.1 -8.2 -8.8 11/22/2005 01:40:00 12 1 14.9 9.5 12.4 1.1 15.3 9.5 359 6 355 305 -8.5 0.1 -8.2 -8.6 11/22/2005 01:50:00 12.2 1.1 14.5 9.5 12.5 1.1 15.6 9.1 355 5 352 305 -8.6 0.1 -8.2 -8.8 11/22/2005 02:00:00 12.7 1.2 16.1 10.3 12.9 1.3 16.4 9.9 354 6 349 305 -8.4 0.1 -7.7 -8.8 11/22/2005 02:10:00 13.4 1.2 16.1 10.3 13.6 1.3 16.4 10.3 356 5 3 305 -8.6 0.1 -8.2 -8.8 11/22/2005 02:20:00 12.7 1.3 17.2 9.9 13 1.3 17.6 9.9 1 6 351 305 -8.6 0.1 -8.2 -8.8 11/22/2005 02:30:00 13.2 1.6 16.8 9.5 13.5 1.6 17.2 9.9 0 6 352 305 -8.6 0.1 -8.2 -8.8 11/22/2005 02:40:00 13.1 1.1 15.6 10.7 13.3 1.1 16.4 9.9 4 5 352 305 -8.6 0.1 -8.2 -8.8 11/22/2005 02:50:00 12.6 1.1 15.6 9.1 12.8 1.1 16.1 9.1 7 6 10 305 -8.6 0 -8.2 -8.8 11/22/2005 03:00:00 12.3 1.2 15.6 9.5 12.5 1.3 16.1 9.5 5 6 12 305 -8.6 0.1 -8.2 -8.8 11/22/2005 03:10:00 12.6 1.1 15.3 9.9 12.8 1.2 15.6 10.3 3 5 353 305 -8.5 0.1 -8.2 -8.8 11/22/2005 03:20:00 12.6 1.3 16.1 9.5 12.8 1.5 16.4 9.1 2 5 3 305 -8.4 0.1 -7.9 -8.8 11/22/2005 03:30:00 13.5 1.3 16.4 9.5 13.7 1.3 16.8 9.5 4 5 359 305 -8.3 0.1 -7.7 -8.6 11/22/2005 03:40:00 14.2 1.2 16.8 11.5 14.4 1.3 17.9 11.5 0 5 3 305 -8.3 0 -7.9 -8.6 11/22/2005 03:50:00 13.2 1.1 16.4 10.3 13.4 1.1 16.4 10.3 4 6 9 305 -8.4 0.1 -7.7 -8.6 11/22/2005 04:00:00 13.6 1.1 16.4 10.3 13.8 1.1 16.8 9.9 1 5 2 305 -8.4 0 -8.2 -8.6 11/22/2005 04:10:00 13.7 1.3 17.6 10.7 13.9 1.4 17.2 10.7 5 6 6 305 -8.4 0 -7.9 -8.6 11/22/2005 04:20:00 13.8 1 16.1 11.5 13.9 1 16.4 11.5 1 6 354 305 -8.5 0.1 -8.2 -8.8 11/22/2005 04:30:00 13.5 1.2 16.4 10.3 13.7 1.2 16.8 10.7 1 5 2 305 -8.5 0.1 -8.2 -8.8 11/22/2005 04:40:00 14 1.2 17.2 9.9 14.2 1.2 17.2 10.7 2 5 3 305 -8.4 0.1 -7.9 -8.6 11/22/2005 04:50:00 14.4 1.6 17.9 10.3 14.6 1.7 18.3 10.7 357 5 357 305 -8.5 0 -8.2 -8.8 11/22/2005 05:00:00 14.6 0.9 17.2 11.8 14.9 1 17.2 11.8 358 4 355 305 -8.5 0.1 -7.9 -8.8 11/22/2005 05:10:00 14.2 1 16.4 11.8 14.4 1.1 17.2 11.5 358 5 1 305 -8.4 0.1 -7.9 -8.8 11/22/2005 05:20:00 14.3 1.2 16.8 10.7 14.7 1.2 17.9 10.7 359 5 354 305 -8.4 0.2 -7.9 -8.8 11/22/2005 05:30:00 14.9 1.2 17.9 11.8 15.2 1.2 18.7 12.2 355 4 352 305 -8.5 0.1 -7.9 -8.8 11/22/2005 05:40:00 14 1.3 17.6 11.1 14.3 1.3 17.9 11.1 358 5 353 305 -8.4 0 -7.9 -8.6 11/22/2005 05:50:00 13.9 1.1 17.2 11.1 14.1 1.2 17.9 11.1 358 5 359 305 -8.3 0 -7.9 -8.6 11/22/2005 06:00:00 13.6 1 16.4 10.3 13.9 1.1 16.8 10.3 356 5 346 305 -8.3 0 -7.9 -8.4 11/22/2005 06:10:00 13.9 1.1 16.8 11.5 14.2 1.2 17.2 11.5 357 5 359 305 -8.3 0 -7.9 -8.6 11/22/2005 06:20:00 14.1 1.1 16.4 11.5 14.4 1.1 16.8 11.5 354 4 353 305 -8.3 0.1 -7.7 -8.6 11/22/2005 06:30:00 14.2 1.1 16.4 10.3 14.5 1.2 17.2 11.1 355 5 352 305 -8.3 0 -7.7 -8.6 11/22/2005 06:40:00 15 1.1 17.6 11.8 15.2 1.1 17.9 12.2 355 5 355 305 -8 0.1 -7.5 -8.4 11/22/2005 06:50:00 15.5 0.9 17.2 12.6 15.7 1 17.6 12.6 355 5 355 305 -8.3 0 -7.7 -8.4 11/22/2005 07:00:00 14.5 1 16.8 12.2 14.7 1 17.2 12.2 357 5 353 305 -8.2 0.1 -7.7 -8.4 11/22/2005 07:10:00 14.1 1.2 17.9 11.1 14.4 1.3 17.9 10.7 359 5 353 305 -7.9 0.1 -7.3 -8.2 11/22/2005 07:20:00 15.1 1.2 18.3 12.6 15.4 1.2 18.3 12.2 354 5 355 305 -7.8 0.1 -7.3 -8.2 11/22/2005 07:30:00 14.7 1.3 17.9 11.5 15 1.4 18.7 11.5 354 5 352 305 -7.8 0.1 -7.3 -8.2 11/22/2005 07:40:00 15.2 1.1 18.7 11.8 15.5 1.2 18.3 11.8 355 5 356 305 -7.8 0.1 -7.3 -7.9 11/22/2005 07:50:00 15.5 1.2 18.3 12.2 15.8 1.3 18.7 11.5 355 4 358 305 -7.7 0.1 -7.3 -7.9 11/22/2005 08:00:00 14.8 1.2 17.6 11.5 15 1.2 17.9 11.8 357 4 5 305 -7.8 0 -7.3 -8.2 11/22/2005 08:10:00 14.3 1.2 18.3 11.8 14.6 1.3 19.1 11.5 352 6 4 305 -7.9 0 -7.7 -8.2 11/22/2005 08:20:00 15 1.2 18.3 11.8 15.2 1.3 19.1 11.8 356 4 355 305 -7.7 0 -7.1 -7.9 11/22/2005 08:30:00 14.2 1.5 17.6 10.3 14.4 1.5 18.3 10.3 357 4 353 305 -7.9 0.1 -7.3 -8.2 11/22/2005 08:40:00 14.7 1.2 17.2 11.1 14.9 1.3 17.9 11.1 357 4 353 305 -7.9 0.1 -7.7 -8.2 11/22/2005 08:50:00 14.5 1.1 17.2 11.5 14.8 1.1 17.2 12.2 355 5 356 305 -7.9 0.1 -7.3 -8.2 11/22/2005 09:00:00 14.4 1 16.8 11.5 14.6 1 17.6 11.5 356 5 355 305 -8.1 0.1 -7.5 -8.4 11/22/2005 09:10:00 15 1 17.2 12.2 15.4 1 17.9 12.6 354 5 357 305 -8 0.1 -7.5 -8.2 11/22/2005 09:20:00 13.9 1.2 17.6 11.1 14.2 1.3 17.9 11.1 354 6 348 305 -7.9 0.1 -7.5 -8.2 11/22/2005 09:30:00 14.7 1.1 17.2 11.1 15 1.2 17.9 11.5 0 5 354 305 -7.8 0 -7.3 -8.2 11/22/2005 09:40:00 14.9 1.3 18.7 11.5 15.2 1.3 18.7 11.5 356 5 348 305 -7.8 0.1 -7.1 -8.2 11/22/2005 09:50:00 14.9 1.4 17.6 11.5 15.3 1.4 18.7 12.2 355 5 345 305 -7.8 0 -7.3 -8.2 11/22/2005 10:00:00 14.6 1.3 17.6 11.1 14.9 1.3 18.3 10.7 356 5 358 305 -7.7 0.1 -7.3 -8.2 11/22/2005 10:10:00 14.7 1.1 17.2 11.8 15 1.2 17.9 11.5 359 5 353 305 -7.5 0.1 -6.9 -7.7 11/22/2005 10:20:00 15 1.4 18.7 11.5 15.3 1.5 19.5 12.2 357 4 1 305 -7.7 0.1 -7.1 -8.2 11/22/2005 10:30:00 15.4 1.1 17.6 12.2 15.7 1.2 18.3 11.8 356 4 354 305 -7.8 0 -7.3 -7.9 11/22/2005 10:40:00 14.8 1.1 17.6 12.2 15.1 1.1 17.9 12.2 355 4 353 305 -7.8 0 -7.3 -7.9 11/22/2005 10:50:00 15.2 1 18.3 13 15.4 1.1 18.3 12.2 354 6 345 305 -7.8 0.1 -7.3 -7.9 11/22/2005 11:00:00 15.2 1.4 18.7 11.8 15.6 1.4 19.1 12.2 355 5 352 305 -7.8 0 -7.3 -7.9 11/22/2005 11:10:00 15.8 1.2 18.3 12.2 16 1.2 18.7 12.6 352 5 355 305 -7.8 0 -7.3 -8.2 11/22/2005 11:20:00 15.6 1.2 18.3 12.6 15.9 1.2 18.7 12.2 351 4 348 305 -7.9 0.1 -7.5 -8.2 11/22/2005 11:30:00 14.9 1.2 19.9 11.8 15.3 1.2 19.9 12.6 353 5 0 305 -8 0.1 -7.7 -8.2 11/22/2005 11:40:00 15.5 1 18.3 12.2 15.8 1.1 18.3 13 354 5 353 305 -8 0.1 -7.7 -8.4 11/22/2005 11:50:00 15.7 1.1 18.7 12.6 16 1.2 19.1 12.2 358 5 355 305 -7.9 0.1 -7.3 -8.2 11/22/2005 12:00:00 15.1 1.2 18.7 11.8 15.4 1.3 19.9 12.6 355 5 355 305 -8 0.1 -7.5 -8.4 11/22/2005 12:10:00 15.9 1.2 18.3 13 16.1 1.3 19.1 12.6 352 4 353 305 -8 0.1 -7.5 -8.2 11/22/2005 12:20:00 15.6 1.2 18.7 12.6 15.9 1.2 18.7 12.6 353 5 353 305 -8.1 0.1 -7.7 -8.2 11/22/2005 12:30:00 15.2 1.1 18.3 12.6 15.5 1.2 18.3 12.2 354 6 351 305 -8 0.1 -7.5 -8.2 11/22/2005 12:40:00 14.9 1.1 18.3 11.5 15.2 1.1 18.3 11.8 354 5 353 305 -7.9 0.1 -7.5 -8.2 11/22/2005 12:50:00 14.5 1.1 17.9 12.2 14.8 1.2 17.9 12.6 356 5 358 305 -7.9 0.1 -7.3 -8.2 11/22/2005 13:00:00 14.6 1.2 17.6 11.8 14.9 1.2 17.9 11.5 355 5 3 305 -8 0 -7.7 -8.2 11/22/2005 13:10:00 15.5 1.2 18.7 12.6 15.7 1.3 19.1 12.6 355 4 357 305 -8 0.1 -7.3 -8.2 11/22/2005 13:20:00 15.1 1 17.9 12.2 15.4 1.1 18.7 13 354 5 351 305 -8.1 0.1 -7.7 -8.2 11/22/2005 13:30:00 14.5 1.1 17.2 11.5 14.8 1.2 17.2 12.2 354 4 354 305 -8.2 0 -7.7 -8.4 11/22/2005 13:40:00 14.4 0.9 16.8 11.8 14.6 1 17.6 11.8 357 4 355 305 -8.2 0 -7.7 -8.4 11/22/2005 13:50:00 14.4 1.1 17.6 11.5 14.7 1.2 17.6 11.1 354 5 359 305 -8.1 0.1 -7.7 -8.4 11/22/2005 14:00:00 14.2 1.1 16.8 11.5 14.6 1.2 17.9 11.5 358 5 2 305 -8.2 0 -7.7 -8.4 11/22/2005 14:10:00 14.1 0.8 15.6 11.5 14.4 0.9 16.4 11.8 357 4 351 305 -8.4 0 -7.9 -8.6 11/22/2005 14:20:00 14.1 0.8 16.8 10.7 14.3 0.9 17.2 11.5 356 5 359 305 -8.4 0 -7.9 -8.6 11/22/2005 14:30:00 13.6 1 16.1 11.5 13.9 1.1 16.4 11.1 354 5 355 305 -8.5 0.1 -8.2 -8.8 11/22/2005 14:40:00 13.6 1 16.8 11.5 14 1.1 16.8 11.5 351 4 351 305 -8.6 0.1 -8.2 -8.8 11/22/2005 14:50:00 13.9 1.1 17.9 10.3 14.2 1.2 17.2 10.3 349 4 348 305 -8.5 0.1 -8.2 -8.8 11/22/2005 15:00:00 13.2 1.1 15.6 11.1 13.5 1.2 16.8 11.1 351 5 349 305 -8.5 0.1 -7.9 -8.8 11/22/2005 15:10:00 13.6 1 16.1 10.7 13.9 1 16.1 10.3 351 4 352 305 -8.4 0 -7.9 -8.6 11/22/2005 15:20:00 13.6 0.8 15.3 10.7 14 0.9 16.1 11.5 352 5 348 305 -8.4 0.1 -7.9 -8.8 11/22/2005 15:30:00 14.1 0.9 16.8 11.8 14.4 1 16.4 11.1 351 5 352 305 -8.6 0.1 -8.2 -8.8 11/22/2005 15:40:00 14.2 1 16.4 11.5 14.6 1 16.8 12.2 353 5 351 305 -8.7 0.1 -8.2 -9 11/22/2005 15:50:00 14.2 0.9 16.4 11.5 14.6 1 16.8 11.8 350 4 352 305 -8.7 0 -8.4 -8.8 11/22/2005 16:00:00 14.3 0.9 16.1 11.8 14.6 1 17.2 12.2 352 4 351 305 -8.7 0.1 -8.2 -9 11/22/2005 16:10:00 14.5 0.9 16.8 11.8 14.9 1 17.2 12.2 350 3 348 305 -8.8 0 -8.4 -9 11/22/2005 16:20:00 14.4 1 17.2 11.8 14.8 1 17.6 11.8 350 3 353 305 -8.7 0 -8.4 -9 11/22/2005 16:30:00 14.6 1 16.8 11.8 14.9 1.1 17.6 11.8 351 5 354 305 -8.8 0 -8.4 -9 11/22/2005 16:40:00 14.3 0.8 16.4 11.8 14.6 0.9 16.4 12.2 350 6 342 305 -8.7 0.1 -8.2 -9 11/22/2005 16:50:00 14 1 16.4 11.1 14.4 1.1 17.2 11.1 345 4 344 305 -8.8 0 -8.4 -9 11/22/2005 17:00:00 13.7 1 16.1 10.7 14 1.1 16.4 11.1 349 5 350 305 -8.6 0.1 -8.2 -8.8 11/22/2005 17:10:00 13.9 1 16.8 11.8 14.3 1 17.2 11.8 351 4 352 305 -8.7 0 -8.4 -8.8 11/22/2005 17:20:00 14.2 1 16.4 11.5 14.5 1.1 17.6 11.5 348 4 351 305 -8.7 0.1 -8.4 -8.8 11/22/2005 17:30:00 14.1 1 16.4 10.3 14.4 1.1 16.8 11.1 347 4 343 305 -8.6 0.1 -8.2 -8.8 11/22/2005 17:40:00 14.4 1.2 17.2 11.1 14.7 1.2 17.6 11.8 351 4 345 305 -8.6 0.1 -8.2 -8.8 11/22/2005 17:50:00 13.7 1 16.8 11.5 14 1.1 16.8 11.5 352 5 350 305 -8.6 0.1 -8.2 -8.8 11/22/2005 18:00:00 14.3 0.8 16.4 12.2 14.6 0.9 16.8 11.5 356 5 357 305 -8.5 0.1 -7.9 -8.8 11/22/2005 18:10:00 13.3 1.2 16.1 9.9 13.7 1.3 17.2 10.7 352 5 347 305 -8.7 0 -8.4 -9.2 11/22/2005 18:20:00 12.9 0.9 15.3 10.7 13.1 1 15.6 10.7 354 5 359 305 -8.7 0 -8.2 -8.8 11/22/2005 18:30:00 12.7 0.9 14.9 9.9 13 1 15.3 10.3 357 6 2 305 -8.7 0 -8.2 -8.8 11/22/2005 18:40:00 13.1 1 15.3 10.7 13.4 1.1 15.6 10.3 355 5 350 305 -8.7 0 -8.2 -9 11/22/2005 18:50:00 13.4 1 16.8 11.5 13.8 1.1 17.2 11.1 352 5 351 305 -8.8 0 -8.4 -9.2 11/22/2005 19:00:00 14 0.9 16.1 11.1 14.3 1 16.4 11.5 353 4 354 305 -9 0 -8.6 -9.2 11/22/2005 19:10:00 13.9 0.8 15.6 11.8 14.3 0.9 16.4 11.8 350 5 350 305 -8.9 0.1 -8.6 -9.2 11/22/2005 19:20:00 13.5 1 15.3 10.7 13.8 1.1 16.4 11.1 353 4 347 305 -8.9 0.1 -8.4 -9.2 11/22/2005 19:30:00 13.1 1 15.3 10.3 13.5 1 16.1 10.3 352 6 340 305 -8.9 0 -8.6 -9.2 11/22/2005 19:40:00 13.2 1.1 16.1 10.3 13.5 1.1 16.1 10.3 348 5 352 305 -8.9 0.1 -8.4 -9.2 11/22/2005 19:50:00 13.5 0.9 16.4 10.7 13.8 0.9 17.2 11.1 349 5 348 305 -8.9 0.1 -8.4 -9.2 11/22/2005 20:00:00 13.2 1.2 16.4 10.3 13.5 1.3 17.2 11.1 349 5 348 305 -8.9 0.1 -8.4 -9.2 11/22/2005 20:10:00 13.3 1.2 16.1 10.3 13.6 1.3 16.8 9.9 344 5 357 305 -9.1 0.1 -8.8 -9.2 11/22/2005 20:20:00 13.6 0.9 16.1 11.5 13.9 1 16.8 11.5 346 7 341 305 -9.1 0.1 -8.6 -9.2 11/22/2005 20:30:00 13.6 1 15.3 11.1 13.9 1 16.4 10.7 343 6 340 305 -9.2 0.1 -8.8 -9.4 11/22/2005 20:40:00 14.3 1 16.4 11.1 14.6 1.1 16.8 11.8 347 5 353 305 -9.3 0 -8.8 -9.4 11/22/2005 20:50:00 14.4 1.2 16.8 11.1 14.7 1.3 17.9 11.5 348 5 346 305 -9.3 0.1 -8.8 -9.6 11/22/2005 21:00:00 14.6 1.2 17.9 11.8 15 1.3 18.3 11.5 346 4 345 305 -9.4 0 -9 -9.6 11/22/2005 21:10:00 14.8 0.9 16.8 12.2 15.2 1 17.6 12.2 345 4 351 305 -9.5 0 -9 -9.6 11/22/2005 21:20:00 15 0.8 17.2 12.6 15.4 0.9 17.9 12.6 347 4 344 305 -9.6 0.1 -9.2 -9.8 11/22/2005 21:30:00 14.7 0.9 17.2 11.5 15.1 1 17.2 11.8 343 4 340 305 -9.8 0 -9.4 -10 11/22/2005 21:40:00 14.8 1 16.8 11.8 15.2 1 17.2 12.2 344 4 341 305 -9.8 0 -9.2 -10 11/22/2005 21:50:00 13.6 1 16.4 10.7 13.8 1 16.8 11.1 346 5 343 305 -9.6 0.1 -9.2 -9.8 11/22/2005 22:00:00 13.4 0.9 15.3 10.7 13.7 0.9 15.6 11.1 344 6 340 305 -9.7 0.1 -9.2 -10 11/22/2005 22:10:00 13.5 0.9 15.3 11.1 13.9 1 16.1 10.7 342 5 337 305 -9.8 0 -9.4 -10 11/22/2005 22:20:00 13.9 1 16.1 11.1 14.2 1.1 16.4 11.5 346 6 350 305 -9.7 0.1 -9.2 -9.8 11/22/2005 22:30:00 13.6 0.9 15.6 11.1 13.9 1 16.8 11.5 347 6 350 305 -9.5 0 -9.2 -9.8 11/22/2005 22:40:00 14.3 1.1 16.8 10.7 14.6 1.2 17.2 10.7 346 5 343 305 -9.6 0.1 -9 -9.8 11/22/2005 22:50:00 14.4 0.8 16.8 12.2 14.7 0.9 16.8 12.2 351 5 348 305 -9.8 0.1 -9.2 -10 11/22/2005 23:00:00 14.5 1 16.4 11.1 14.8 1.1 16.8 11.8 351 6 357 305 -9.9 0.1 -9.2 -10.2 11/22/2005 23:10:00 15 1.2 17.6 11.5 15.4 1.2 17.9 12.2 354 4 355 305 -10.3 0.2 -9.6 -10.9 11/22/2005 23:20:00 14.4 1 16.4 11.8 14.8 1 17.2 11.8 355 6 356 305 -10.3 0.1 -9.8 -10.7 11/22/2005 23:30:00 14.4 0.8 16.8 11.8 14.5 1 16.8 11.8 352 7 358 305 -10.4 0 -9.8 -10.7 11/22/2005 23:40:00 14.4 1 16.4 11.8 14.7 1.1 16.8 11.5 350 4 353 305 -10.4 0 -10 -10.7 11/22/2005 23:50:00 14.3 1.1 16.4 10.7 14.6 1.1 17.2 11.8 352 6 351 305 -10.2 0.1 -10 -10.4 11/23/2005 00:00:00 14.6 1.1 17.2 11.1 14.9 1.2 17.2 10.7 347 5 343 305 -10.4 0.1 -9.8 -10.9 11/23/2005 00:10:00 13.8 0.9 16.8 11.5 14.1 1 17.6 10.7 350 5 342 305 -10.4 0 -10 -10.7 11/23/2005 00:20:00 13.1 1.1 15.3 10.3 13.5 1 16.1 10.7 346 6 351 305 -10.3 0 -9.8 -10.7 11/23/2005 00:30:00 13.3 0.9 16.1 10.7 13.7 1 16.4 11.5 347 6 340 305 -10.4 0.1 -9.8 -10.7 11/23/2005 00:40:00 13.3 1 15.3 10.3 13.7 1.1 16.1 9.9 354 4 357 305 -10.4 0 -10 -10.7 11/23/2005 00:50:00 13.3 0.9 15.3 10.7 13.6 1 16.1 10.7 351 5 347 305 -10.5 0 -10.2 -10.9 11/23/2005 01:00:00 13.4 0.8 15.3 11.5 13.8 1 15.6 10.7 348 4 351 305 -10.7 0.1 -10.2 -10.9 11/23/2005 01:10:00 13.4 1 15.6 10.7 13.7 1 16.1 10.7 345 5 345 305 -10.7 0.1 -10.2 -10.9 11/23/2005 01:20:00 14 0.8 16.1 11.8 14.4 0.9 16.8 11.5 350 5 353 305 -10.8 0.1 -10.4 -10.9 11/23/2005 01:30:00 14 1 16.8 11.5 14.3 1.1 17.2 11.5 346 5 343 305 -10.9 0 -10.4 -11.1 11/23/2005 01:40:00 13.6 0.8 15.3 11.1 13.9 0.9 16.1 11.1 347 5 348 305 -10.9 0 -10.4 -11.3 11/23/2005 01:50:00 13.4 0.9 15.6 11.1 13.8 1 16.1 11.5 352 6 345 305 -10.9 0.1 -10.4 -11.1 11/23/2005 02:00:00 13.1 1.2 16.4 10.3 13.4 1.3 16.8 10.7 352 5 355 305 -11 0 -10.7 -11.3 11/23/2005 02:10:00 12.4 1 16.8 10.3 12.7 1.1 17.2 10.3 352 5 5 305 -10.9 0.1 -10.4 -11.3 11/23/2005 02:20:00 12.3 1 14.9 9.5 12.7 1.1 15.6 9.9 353 5 357 305 -10.9 0 -10.4 -11.1 11/23/2005 02:30:00 12.6 1 15.3 10.3 12.9 1 15.6 10.7 352 4 354 305 -10.8 0.1 -10.4 -10.9 11/23/2005 02:40:00 13.7 1.1 16.4 10.3 14 1.2 16.8 9.9 355 5 350 305 -10.5 0.1 -10 -10.9 11/23/2005 02:50:00 14.1 1 16.8 11.8 14.4 1 16.8 12.2 355 5 3 305 -10.8 0.1 -10.4 -11.1 11/23/2005 03:00:00 14.3 0.9 16.4 11.8 14.5 1.1 17.2 11.1 356 6 356 305 -10.9 0 -10.7 -11.3 11/23/2005 03:10:00 13.9 1 17.6 11.5 14.2 1.1 16.8 11.1 350 5 344 305 -11 0 -10.9 -11.3 11/23/2005 03:20:00 12.7 0.9 14.5 9.9 13 1 15.3 9.9 349 6 347 305 -11 0.1 -10.4 -11.3 11/23/2005 03:30:00 13.9 1.2 16.4 11.5 14.2 1.3 16.8 11.1 351 5 352 305 -10.7 0.1 -10.4 -11.1 11/23/2005 03:40:00 13.3 1.1 15.6 10.3 13.5 1.3 16.4 10.7 350 5 344 305 -10.8 0.1 -10.4 -11.1 11/23/2005 03:50:00 13 1.1 16.1 9.9 13.2 1.2 16.4 9.9 350 6 352 305 -10.8 0.1 -10.4 -11.1 11/23/2005 04:00:00 13.7 1.2 16.8 11.1 14.1 1.3 17.2 10.7 350 5 341 305 -10.7 0.1 -10.4 -10.9 11/23/2005 04:10:00 13.1 1 16.1 9.1 13.5 1.1 16.4 9.9 351 5 352 305 -10.8 0.1 -10.4 -10.9 11/23/2005 04:20:00 13.6 1.2 17.6 10.7 13.9 1.2 18.3 11.1 352 5 350 305 -10.7 0.1 -10.4 -10.9 11/23/2005 04:30:00 13.3 1.1 16.1 10.3 13.6 1.2 16.4 10.7 349 6 1 305 -10.7 0 -10.2 -10.9 11/23/2005 04:40:00 13.8 1 16.1 10.3 14.1 1.2 16.4 9.5 353 5 358 305 -10.6 0.1 -10 -10.9 11/23/2005 04:50:00 13 1 16.1 10.3 13.2 1.1 16.4 11.1 352 4 353 305 -10.6 0.1 -10.2 -10.9 11/23/2005 05:00:00 13.4 1.1 16.1 10.7 13.8 1 16.8 11.5 348 7 345 305 -10.7 0.1 -10.4 -10.9 11/23/2005 05:10:00 13.9 1.2 17.2 11.1 14.2 1.3 17.9 10.7 349 6 345 305 -10.7 0.1 -10.4 -10.9 11/23/2005 05:20:00 13.9 1.1 16.4 10.7 14.2 1.2 17.6 10.7 350 6 343 305 -10.8 0.1 -10.4 -11.1 11/23/2005 05:30:00 13.7 1 16.4 11.1 14 1.1 16.8 11.5 353 5 345 305 -10.8 0.1 -10.4 -11.1 11/23/2005 05:40:00 13.8 1 16.8 10.3 14 1.1 16.8 10.7 349 6 352 305 -10.8 0.1 -10.4 -10.9 11/23/2005 05:50:00 13.8 1.1 16.4 10.3 14.1 1.2 16.8 10.7 351 6 356 305 -10.7 0.1 -10.4 -10.9 11/23/2005 06:00:00 14.5 1 16.8 10.7 14.7 1.1 17.2 11.1 355 5 357 305 -10.8 0.1 -10.4 -11.1 11/23/2005 06:10:00 13.7 1.2 16.4 10.7 13.9 1.3 17.2 10.3 354 7 352 305 -10.7 0.1 -10.4 -11.1 11/23/2005 06:20:00 14.2 1.2 17.6 11.1 14.5 1.3 17.9 11.1 348 6 343 305 -10.7 0.1 -10.4 -10.9 11/23/2005 06:30:00 14.3 1.2 17.6 11.5 14.7 1.3 17.9 11.1 348 5 339 305 -10.8 0 -10.7 -10.9 11/23/2005 06:40:00 14.3 1.1 16.8 11.1 14.7 1.2 17.2 10.7 351 5 350 305 -10.7 0 -10.4 -10.9 11/23/2005 06:50:00 14.3 1.2 17.6 11.5 14.6 1.2 17.9 11.1 352 5 347 305 -10.8 0 -10.4 -10.9 11/23/2005 07:00:00 14.4 1.3 17.2 11.5 14.9 1.3 17.6 11.8 346 5 344 305 -10.9 0 -10.7 -11.3 11/23/2005 07:10:00 13.7 1 16.4 11.5 14 1.1 16.4 11.1 347 5 350 305 -10.8 0.1 -10.4 -11.1 11/23/2005 07:20:00 14.7 1.3 17.6 10.3 15 1.4 18.3 10.7 346 5 340 305 -10.6 0.1 -10.4 -10.9 11/23/2005 07:30:00 15.2 1.3 18.3 12.2 15.4 1.4 19.1 11.8 343 5 340 305 -10.7 0.1 -10.4 -10.9 11/23/2005 07:40:00 16.1 1.1 19.1 12.6 16.4 1.2 19.5 13 349 6 357 305 -10.7 0.1 -10.4 -10.9 11/23/2005 07:50:00 15.9 1.3 19.5 11.8 16.2 1.5 19.5 11.8 349 5 346 305 -10.6 0.1 -10.2 -10.9 11/23/2005 08:00:00 16.4 1.2 19.5 13 16.6 1.3 19.5 13 345 4 341 305 -10.7 0.1 -10.4 -10.9 11/23/2005 08:10:00 15.5 1.1 18.7 12.6 15.8 1.2 18.7 13 347 6 358 305 -10.8 0.1 -10.4 -10.9 11/23/2005 08:20:00 15.1 1.3 18.3 11.5 15.4 1.5 19.5 11.5 347 5 352 305 -10.7 0 -10.2 -10.9 11/23/2005 08:30:00 15.1 1.1 17.6 11.8 15.3 1.1 17.9 12.2 347 6 350 305 -10.7 0.1 -10.4 -10.9 11/23/2005 08:40:00 15.3 1.3 18.3 11.1 15.5 1.5 19.1 11.5 349 5 350 305 -10.7 0.1 -10 -10.9 11/23/2005 08:50:00 15.9 0.9 17.9 12.2 16.1 1.1 19.1 11.8 344 4 346 305 -10.7 0 -10.4 -10.9 11/23/2005 09:00:00 15.5 1.2 17.9 11.8 15.9 1.3 18.7 12.6 348 5 342 305 -10.7 0.1 -10.4 -10.9 11/23/2005 09:10:00 15.1 1.2 18.3 11.5 15.4 1.2 18.7 12.6 346 5 348 305 -10.5 0.1 -10 -10.9 11/23/2005 09:20:00 15.7 1.3 18.7 11.8 16 1.4 19.1 11.8 347 6 355 305 -10.4 0 -10 -10.9 11/23/2005 09:30:00 15.5 1.7 18.7 11.1 15.7 1.9 19.9 10.7 346 5 339 305 -10.4 0.1 -9.8 -10.9 11/23/2005 09:40:00 16 1.3 20.2 12.2 16.3 1.5 20.2 12.6 345 5 343 305 -10.4 0.1 -10 -10.9 11/23/2005 09:50:00 15.8 1.3 19.1 12.6 16.2 1.4 19.9 12.2 348 5 352 305 -10.4 0 -10 -10.7 11/23/2005 10:00:00 15.4 1.1 18.3 12.2 15.6 1.3 19.1 11.8 349 6 343 305 -10.3 0 -10 -10.4 11/23/2005 10:10:00 16.3 1.1 19.5 13 16.7 1.2 20.2 13.3 347 5 349 305 -10.4 0 -10 -10.7 11/23/2005 10:20:00 15.3 1.2 18.7 12.6 15.4 1.2 19.9 11.8 351 6 344 305 -10.2 0.2 -9.6 -10.7 11/23/2005 10:30:00 16.6 1.2 19.1 12.6 17.1 1.3 19.9 13 347 4 343 305 -10.4 0 -10 -10.7 11/23/2005 10:40:00 15.6 1.2 18.7 12.2 15.8 1.3 18.7 12.2 350 6 350 305 -10.2 0.1 -9.8 -10.4 11/23/2005 10:50:00 15.9 1.3 18.7 11.8 16.1 1.4 19.5 11.8 354 6 347 305 -10.1 0.1 -9.6 -10.4 11/23/2005 11:00:00 16.6 1.5 20.6 11.8 16.8 1.7 21 13 353 6 352 305 -10.2 0 -10 -10.4 11/23/2005 11:10:00 15.7 1.2 19.9 11.5 16 1.3 19.9 13 349 5 353 305 -10.3 0 -10 -10.7 11/23/2005 11:20:00 15.7 1.5 19.5 12.6 16 1.5 19.9 13 349 6 347 305 -10.2 0.1 -10 -10.4 11/23/2005 11:30:00 15.3 1.3 18.7 10.7 15.6 1.5 19.5 11.1 347 5 341 305 -10.2 0 -10 -10.4 11/23/2005 11:40:00 15.9 1.2 19.5 12.6 16.2 1.3 19.9 13 348 5 345 305 -10.2 0.1 -10 -10.4 11/23/2005 11:50:00 15.9 1.2 18.7 12.6 16.3 1.3 19.5 13 347 4 350 305 -10.2 0 -10 -10.4 11/23/2005 12:00:00 16.4 1.2 19.1 13 16.7 1.2 19.5 13 348 4 351 305 -10.2 0.1 -9.8 -10.4 11/23/2005 12:10:00 15.9 1.4 18.7 12.2 16.2 1.5 19.5 12.6 348 5 350 305 -10.1 0.1 -9.8 -10.4 11/23/2005 12:20:00 16.4 1.3 19.5 12.6 16.7 1.5 20.2 13 350 5 350 305 -10.1 0.1 -9.6 -10.4 11/23/2005 12:30:00 16.8 1.2 19.5 13.3 17.1 1.2 19.9 13 348 5 353 305 -10.1 0.1 -9.8 -10.4 11/23/2005 12:40:00 16.5 1.2 19.9 13.3 16.7 1.2 19.9 13 347 4 347 305 -10 0.1 -9.6 -10.2 11/23/2005 12:50:00 15.9 1.3 19.9 12.6 16.2 1.4 19.9 12.6 345 5 346 305 -10.1 0 -9.6 -10.4 11/23/2005 13:00:00 15.8 1 19.1 13 16.1 1.1 19.1 13.3 346 5 352 305 -10.1 0.1 -9.6 -10.4 11/23/2005 13:10:00 16.1 1.1 18.7 13 16.4 1.2 19.1 13 347 5 341 305 -10.1 0.1 -9.6 -10.4 11/23/2005 13:20:00 15.9 1.4 19.1 12.2 15.9 1.5 19.5 12.2 348 6 345 305 -9.9 0.1 -9.4 -10.2 11/23/2005 13:30:00 16.9 1.2 19.9 11.8 17.1 1.2 20.2 13 347 4 341 305 -9.9 0.1 -9.2 -10.2 11/23/2005 13:40:00 16.1 1.5 19.9 11.1 16.3 1.5 20.6 11.5 347 5 350 305 -9.9 0.1 -9.4 -10 11/23/2005 13:50:00 15.9 1.5 19.1 11.8 16 1.5 19.5 11.5 348 5 344 305 -9.7 0.1 -9.2 -10 11/23/2005 14:00:00 16.8 1.2 19.5 13 17 1.3 19.9 13 343 5 343 305 -9.8 0.1 -9.2 -10 11/23/2005 14:10:00 15.6 1.1 18.7 11.5 15.8 1.2 18.7 12.2 345 6 343 305 -9.6 0.1 -9 -9.8 11/23/2005 14:20:00 15.6 1.5 19.9 11.1 15.8 1.5 19.5 11.1 345 5 339 305 -9.5 0.1 -9 -9.8 11/23/2005 14:30:00 16.1 1.4 19.5 11.1 16.2 1.5 19.5 12.6 346 6 346 305 -9.5 0.1 -9 -9.8 11/23/2005 14:40:00 16.1 1.7 20.2 11.1 16.4 1.7 20.2 12.2 345 6 343 305 -9.5 0.1 -9.2 -9.8 11/23/2005 14:50:00 16.6 1.4 20.2 13 16.8 1.4 21 13.3 345 5 342 305 -9.5 0.1 -9.2 -9.8 11/23/2005 15:00:00 16.2 1.3 19.5 13 16.4 1.5 20.2 13 348 5 341 305 -9.6 0 -9.2 -9.8 11/23/2005 15:10:00 15.9 1.5 19.1 11.5 16.1 1.5 19.5 11.5 350 6 346 305 -9.5 0 -9.2 -9.8 11/23/2005 15:20:00 16.3 1.3 19.9 12.2 16.5 1.5 19.5 13 350 5 346 305 -9.5 0 -9.2 -9.6 11/23/2005 15:30:00 15.9 1.6 19.9 11.8 16.2 1.7 20.2 11.5 348 5 346 305 -9.4 0 -9.2 -9.6 11/23/2005 15:40:00 15.9 1.5 19.5 11.5 16.2 1.5 20.2 12.6 349 5 352 305 -9.4 0 -9.2 -9.6 11/23/2005 15:50:00 15.9 1.2 19.5 11.8 16.1 1.4 20.2 12.2 347 5 349 305 -9.4 0 -9.2 -9.6 11/23/2005 16:00:00 15.9 1.1 18.3 12.6 16.2 1.2 18.7 12.6 347 4 343 305 -9.5 0 -9.2 -9.6 11/23/2005 16:10:00 15.5 1.3 18.7 12.2 15.7 1.4 18.7 12.2 350 5 343 305 -9.4 0 -9.2 -9.6 11/23/2005 16:20:00 15.1 1.3 18.3 11.8 15.3 1.4 19.1 11.8 351 5 353 305 -9.4 0 -9.2 -9.6 11/23/2005 16:30:00 14.6 1.2 17.9 11.5 14.9 1.3 18.3 11.1 348 5 341 305 -9.6 0 -9.2 -9.8 11/23/2005 16:40:00 14.1 1.4 17.6 9.9 14.4 1.5 18.3 10.3 346 5 348 305 -9.5 0.1 -9.2 -9.8 11/23/2005 16:50:00 14.8 1.3 17.9 11.1 14.9 1.4 18.3 11.5 345 5 341 305 -9.5 0 -9.2 -9.6 11/23/2005 17:00:00 14.4 1.2 17.6 10.3 14.6 1.2 18.3 11.5 348 6 348 305 -9.7 0.1 -9.2 -9.8 11/23/2005 17:10:00 14.2 1.2 17.2 10.7 14.4 1.3 17.9 11.5 348 5 350 305 -9.7 0.1 -9.2 -9.8 11/23/2005 17:20:00 14.4 1.1 16.8 10.3 14.5 1.2 17.9 10.3 348 4 340 305 -9.7 0.1 -9.2 -9.8 11/23/2005 17:30:00 14.5 1.1 17.2 11.1 14.7 1.3 17.6 11.5 347 4 343 305 -9.6 0.1 -9.2 -9.8 11/23/2005 17:40:00 15.2 1.2 17.9 11.8 15.5 1.3 18.7 12.2 348 4 346 305 -9.5 0 -9 -9.6 11/23/2005 17:50:00 15.7 1.4 18.3 10.3 15.9 1.6 18.7 10.7 351 4 351 305 -9.3 0.1 -8.8 -9.6 11/23/2005 18:00:00 15.4 1.2 17.6 11.8 15.6 1.3 18.7 11.8 348 5 350 305 -9.1 0.1 -8.6 -9.4 11/23/2005 18:10:00 16 1.1 18.3 13 16.2 1.3 18.7 12.2 347 4 350 305 -9.3 0 -8.8 -9.6 11/23/2005 18:20:00 15.7 1.1 18.3 11.1 15.8 1.2 17.9 11.5 348 5 341 305 -9.3 0 -8.6 -9.6 11/23/2005 18:30:00 15.6 1.1 17.9 12.2 15.8 1.2 19.1 11.5 349 4 350 305 -9.4 0 -9 -9.6 11/23/2005 18:40:00 15.8 1.3 19.1 12.2 16.1 1.4 19.5 12.2 348 6 339 305 -9.5 0.1 -9 -9.8 11/23/2005 18:50:00 15.2 1.5 17.9 11.1 15.3 1.7 18.7 10.3 342 6 351 305 -9.4 0 -9 -9.6 11/23/2005 19:00:00 15.5 1.2 18.3 11.5 15.7 1.3 19.1 11.8 347 5 355 305 -9.3 0 -8.8 -9.6 11/23/2005 19:10:00 15.3 1.1 17.9 10.7 15.6 1.1 18.3 11.5 351 5 355 305 -9.3 0 -9 -9.6 11/23/2005 19:20:00 15.2 1.7 19.1 10.7 15.5 1.7 19.1 10.7 343 6 339 305 -9.4 0.1 -9 -9.6 11/23/2005 19:30:00 14.8 1.2 17.9 11.8 15 1.3 18.3 11.8 336 5 337 305 -9.6 0.1 -9.2 -9.8 11/23/2005 19:40:00 14.6 1.3 17.9 10.7 14.7 1.4 18.7 11.1 338 5 338 305 -9.7 0.1 -9.4 -9.8 11/23/2005 19:50:00 14.8 1.3 17.9 11.1 14.9 1.4 17.9 11.5 342 5 339 305 -9.8 0 -9.6 -10 11/23/2005 20:00:00 14.5 1.2 16.8 10.3 14.6 1.3 17.2 10.7 340 5 346 305 -9.8 0 -9.4 -10 11/23/2005 20:10:00 14.4 1.5 17.9 10.3 14.5 1.7 18.3 10.3 342 5 340 305 -9.8 0 -9.4 -10 11/23/2005 20:20:00 14.9 1.2 17.6 11.8 15.1 1.3 18.3 11.5 344 5 333 305 -9.8 0.1 -9.2 -10 11/23/2005 20:30:00 14.5 1.5 17.6 10.7 14.6 1.5 17.9 11.1 343 6 334 305 -9.9 0 -9.4 -10 11/23/2005 20:40:00 14.3 1.3 17.2 11.1 14.5 1.4 17.2 10.7 340 5 336 305 -9.9 0 -9.6 -10 11/23/2005 20:50:00 14.3 1.7 17.6 9.1 14.5 1.8 17.9 9.9 340 6 343 305 -9.9 0 -9.6 -10.2 11/23/2005 21:00:00 14.9 1.1 17.6 11.5 15 1.2 17.6 11.1 339 5 342 305 -10 0 -9.8 -10.2 11/23/2005 21:10:00 14.7 1.5 17.9 9.9 14.7 1.6 18.7 9.9 341 6 341 305 -9.9 0 -9.8 -10 11/23/2005 21:20:00 14.7 1.3 17.6 11.1 14.9 1.4 17.9 10.7 340 5 336 305 -9.9 0 -9.6 -10 11/23/2005 21:30:00 14.9 1.5 17.9 10.3 15 1.5 18.3 10.3 339 6 342 305 -9.8 0 -9.4 -10 11/23/2005 21:40:00 14.2 1.5 17.9 10.3 14.3 1.5 17.9 11.1 341 6 340 305 -9.8 0.1 -9.2 -10 11/23/2005 21:50:00 15.6 1.3 19.5 11.8 15.7 1.4 19.1 11.1 341 5 339 305 -9.8 0 -9.4 -10 11/23/2005 22:00:00 16.1 1.3 19.5 13 16.2 1.5 20.6 11.8 343 5 344 305 -9.8 0 -9.4 -10 11/23/2005 22:10:00 15.5 1.4 18.7 11.8 15.6 1.5 19.5 11.8 341 5 338 305 -9.7 0.1 -9.2 -10 11/23/2005 22:20:00 16.1 1.3 19.9 12.2 16.2 1.5 19.9 11.5 340 5 337 305 -9.7 0.1 -9.2 -10 11/23/2005 22:30:00 15.6 1.2 19.1 12.2 15.7 1.3 18.7 12.2 341 5 344 305 -9.8 0.1 -9.2 -10 11/23/2005 22:40:00 16.2 1.3 19.5 11.8 16.4 1.4 19.9 12.2 342 5 344 305 -9.8 0.1 -9.4 -10 11/23/2005 22:50:00 16.1 1.2 19.1 12.2 16.2 1.3 19.9 11.8 337 5 328 305 -9.8 0.1 -9.4 -10 11/23/2005 23:00:00 15.1 1.4 18.7 10.3 15.3 1.5 18.3 11.1 341 6 339 305 -9.7 0.1 -9.2 -10 11/23/2005 23:10:00 16.3 1.3 19.5 12.2 16.4 1.4 19.9 13 338 5 336 305 -9.8 0.1 -9.4 -10 11/23/2005 23:20:00 14.9 1.6 17.9 10.7 15.1 1.7 18.7 11.1 344 6 347 305 -9.6 0.2 -9.2 -9.8 11/23/2005 23:30:00 15.4 1.3 18.7 11.5 15.6 1.4 19.5 11.1 343 5 339 305 -9.7 0.1 -9.2 -10 11/23/2005 23:40:00 15.1 1.5 18.7 11.1 15.2 1.6 19.1 11.1 343 5 336 305 -9.6 0.1 -9 -9.8 11/23/2005 23:50:00 16.2 1.1 19.1 13 16.4 1.2 19.1 13 344 6 349 305 -9.8 0 -9.6 -10 11/24/2005 00:00:00 16.8 1.2 19.5 13.3 16.7 1.4 19.5 11.8 344 5 347 305 -9.7 0.1 -9.4 -10 11/24/2005 00:10:00 16.7 1.3 20.2 11.8 16.9 1.4 19.9 11.8 342 5 338 305 -9.8 0 -9.4 -9.8 11/24/2005 00:20:00 16.7 1.5 19.9 13 16.9 1.5 19.9 13 345 4 341 305 -9.8 0 -9.4 -10 11/24/2005 00:30:00 16.7 1 19.5 13 16.8 1.1 19.5 11.5 343 5 341 305 -9.8 0 -9.2 -10 11/24/2005 00:40:00 16.5 1.3 20.2 13 16.7 1.5 20.6 13 343 5 339 305 -9.8 0 -9.6 -10.2 11/24/2005 00:50:00 16.5 1.1 18.7 13 16.6 1.3 19.1 13 341 4 341 305 -9.9 0 -9.2 -10 11/24/2005 01:00:00 15.6 1.2 18.7 11.8 16 1.2 18.3 12.6 346 6 341 305 -9.9 0 -9.6 -10.2 11/24/2005 01:10:00 15.5 1.3 18.7 12.2 15.7 1.3 19.9 12.2 342 6 344 305 -10.1 0 -9.8 -10.2 11/24/2005 01:20:00 15.6 1.2 17.9 11.5 15.8 1.3 18.3 11.8 341 5 340 305 -10.1 0 -9.8 -10.4 11/24/2005 01:30:00 14.2 1.3 16.8 10.7 14.4 1.4 17.6 9.5 339 6 337 305 -10.1 0.1 -9.6 -10.4 11/24/2005 01:40:00 15.3 1.3 19.1 11.8 15.4 1.5 19.5 11.8 347 5 344 305 -10.1 0 -9.6 -10.4 11/24/2005 01:50:00 15 1.7 19.1 11.1 15.1 1.7 19.1 11.1 346 6 350 305 -10.1 0 -9.6 -10.2 11/24/2005 02:00:00 15.2 1.3 17.9 9.9 15.6 1.5 18.7 9.5 344 4 345 305 -10.2 0.1 -9.8 -10.4 11/24/2005 02:10:00 14.8 1 17.9 11.5 15 1.1 17.9 11.8 341 5 341 305 -10.3 0.1 -9.8 -10.4 11/24/2005 02:20:00 15.2 1.2 17.9 11.1 15.4 1.3 18.3 11.8 343 5 343 305 -10.3 0.1 -9.8 -10.4 11/24/2005 02:30:00 15 1.3 18.3 10.7 15.2 1.4 18.7 10.3 344 5 340 305 -10.3 0.1 -9.8 -10.4 11/24/2005 02:40:00 15 1.2 17.6 12.2 15.1 1.2 18.3 11.5 343 6 339 305 -10.3 0.1 -9.8 -10.4 11/24/2005 02:50:00 15.2 1.1 17.6 12.6 15.4 1.1 17.9 11.5 338 5 338 305 -10.4 0 -10 -10.7 11/24/2005 03:00:00 14.8 1.5 18.3 11.1 15 1.5 18.7 11.5 339 5 342 305 -10.4 0 -9.8 -10.9 11/24/2005 03:10:00 14.7 1 17.2 11.5 14.9 1.1 17.2 11.8 338 4 334 305 -10.4 0 -10 -10.9 11/24/2005 03:20:00 15.4 1.1 17.9 11.8 15.6 1.1 17.9 11.8 338 5 326 305 -10.4 0 -10 -10.7 11/24/2005 03:30:00 14.7 1.2 17.2 10.7 14.8 1.3 17.6 11.1 341 6 339 305 -10.4 0 -10 -10.7 11/24/2005 03:40:00 15.5 1.2 18.7 12.2 15.7 1.3 19.1 11.8 345 5 341 305 -10.4 0 -10 -10.7 11/24/2005 03:50:00 15.1 1.7 19.1 11.1 15.4 1.8 18.7 11.1 344 5 344 305 -10.4 0 -10 -10.4 11/24/2005 04:00:00 15.1 1.6 17.9 11.1 15.1 1.7 18.3 11.1 344 5 335 305 -10.5 0.1 -10 -10.9 11/24/2005 04:10:00 15.1 1.6 18.3 10.7 15.2 1.6 18.7 10.7 346 5 345 305 -10.7 0.1 -10.2 -10.9 11/24/2005 04:20:00 15.1 1.6 18.3 11.1 15.3 1.7 18.7 11.5 346 5 340 305 -10.7 0.1 -10.2 -10.9 11/24/2005 04:30:00 14.4 1.2 17.2 11.5 14.5 1.3 17.2 11.5 343 5 344 305 -10.8 0.1 -10.4 -10.9 11/24/2005 04:40:00 14.7 1.5 18.3 11.1 14.7 1.5 17.6 11.5 341 6 341 305 -10.8 0 -10.4 -11.1 11/24/2005 04:50:00 15.4 1.1 17.9 12.2 15.4 1.2 18.3 12.6 345 5 350 305 -10.8 0 -10.4 -10.9 11/24/2005 05:00:00 14.6 1.3 17.2 10.3 14.6 1.4 17.6 10.7 345 6 345 305 -10.8 0 -10.4 -10.9 11/24/2005 05:10:00 15.3 1.3 18.7 12.2 15.3 1.5 19.1 12.2 343 5 351 305 -10.9 0 -10.4 -10.9 11/24/2005 05:20:00 13.6 1.4 16.8 9.5 13.7 1.5 16.8 9.9 344 6 343 305 -10.8 0.1 -10.4 -10.9 11/24/2005 05:30:00 13.6 1.5 17.2 9.9 13.7 1.5 17.6 9.5 344 6 346 305 -10.9 0 -10.4 -10.9 11/24/2005 05:40:00 13.7 1.6 16.8 9.5 13.8 1.7 16.8 9.1 342 5 336 305 -10.9 0 -10.4 -11.1 11/24/2005 05:50:00 14.2 1.2 17.2 10.3 14.4 1.2 17.2 10.7 343 4 346 305 -11 0 -10.4 -11.3 11/24/2005 06:00:00 12.9 1.4 16.1 8.8 13 1.4 16.4 9.1 342 6 348 305 -11 0 -10.7 -11.3 11/24/2005 06:10:00 14.9 1.2 18.3 11.5 15 1.3 19.1 11.8 344 5 337 305 -11.2 0 -10.9 -11.3 11/24/2005 06:20:00 14.5 1.3 16.8 9.9 14.6 1.5 17.2 10.3 342 6 350 305 -11.2 0 -10.9 -11.5 11/24/2005 06:30:00 14.2 1.4 17.2 9.9 14.2 1.4 17.2 10.3 341 6 343 305 -11.2 0 -10.9 -11.5 11/24/2005 06:40:00 14.2 1.5 17.2 9.9 14.3 1.5 17.6 9.5 340 5 345 305 -11.2 0 -10.9 -11.3 11/24/2005 06:50:00 14.2 1.1 17.2 10.3 14.3 1.2 17.2 10.3 339 5 337 305 -11.2 0 -10.9 -11.5 11/24/2005 07:00:00 14.4 1.5 17.6 10.3 14.5 1.5 17.9 9.1 340 6 335 305 -11.3 0 -10.9 -11.5 11/24/2005 07:10:00 14.6 1.4 17.2 9.9 14.6 1.5 17.9 9.1 341 6 344 305 -11.3 0 -10.9 -11.5 11/24/2005 07:20:00 13.8 1.7 17.2 9.5 13.9 1.7 17.6 9.5 338 6 336 305 -11.2 0.1 -10.9 -11.5 11/24/2005 07:30:00 14.3 1.3 16.8 9.9 14.4 1.4 17.6 10.7 340 5 337 305 -11.4 0 -10.9 -11.5 11/24/2005 07:40:00 14.7 1.3 17.6 10.7 14.8 1.4 17.9 11.1 339 6 335 305 -11.5 0 -11.1 -11.7 11/24/2005 07:50:00 15.2 1.2 17.9 12.2 15.4 1.2 18.3 11.8 336 4 329 305 -11.5 0 -11.3 -11.7 11/24/2005 08:00:00 14.4 1.6 17.6 10.3 14.5 1.6 17.9 10.3 340 5 337 305 -11.6 0 -11.3 -11.7 11/24/2005 08:10:00 14.3 1.2 17.2 10.7 14.3 1.3 17.9 10.3 337 5 333 305 -11.6 0 -11.3 -11.7 11/24/2005 08:20:00 14.5 1.2 17.9 11.1 14.6 1.4 17.9 11.1 337 4 341 305 -11.7 0.1 -11.3 -11.9 11/24/2005 08:30:00 14.2 1.5 17.9 10.7 14.3 1.5 17.2 9.9 342 5 343 305 -11.7 0 -11.3 -11.9 11/24/2005 08:40:00 13.9 1.3 17.2 10.3 14 1.3 17.2 10.3 342 6 344 305 -11.6 0 -11.3 -11.7 11/24/2005 08:50:00 13.8 1.2 16.8 9.9 14.1 1.2 16.8 10.7 345 5 343 305 -11.6 0 -11.3 -11.9 11/24/2005 09:00:00 13.9 1.5 16.8 10.3 14 1.5 17.2 10.3 341 6 336 305 -11.6 0 -11.3 -11.9 11/24/2005 09:10:00 14.7 1.2 19.1 11.5 14.9 1.3 19.9 11.5 340 5 333 305 -11.8 0.1 -11.5 -12.1 11/24/2005 09:20:00 14.2 1.2 16.8 11.1 14.3 1.3 17.6 10.3 341 5 339 305 -11.8 0.1 -11.5 -12.1 11/24/2005 09:30:00 14.2 1.3 16.8 10.3 14.3 1.5 17.6 11.1 341 4 341 305 -11.7 0.1 -11.5 -12.1 11/24/2005 09:40:00 13.6 1.3 16.8 10.3 13.8 1.3 17.2 9.9 346 5 344 305 -11.6 0 -11.5 -11.9 11/24/2005 09:50:00 14.9 1 17.6 11.8 15.1 1.2 17.9 11.8 347 4 346 305 -11.8 0.1 -11.5 -12.1 11/24/2005 10:00:00 14.7 1.2 17.2 11.5 14.9 1.3 17.9 11.1 348 4 345 305 -11.8 0 -11.5 -12.1 11/24/2005 10:10:00 14.4 1.2 17.2 11.1 14.6 1.3 17.6 11.5 348 4 352 305 -11.7 0 -11.5 -11.9 11/24/2005 10:20:00 15.5 1.2 17.6 11.8 15.7 1.2 18.3 12.2 352 5 353 305 -11.8 0.1 -11.5 -12.1 11/24/2005 10:30:00 14.4 1.1 17.2 11.1 14.5 1.3 17.6 11.1 353 7 1 305 -11.7 0.1 -11.5 -11.9 11/24/2005 10:40:00 15 1.2 17.6 11.5 15.1 1.3 17.9 11.1 353 5 8 305 -11.8 0.1 -11.7 -12.1 11/24/2005 10:50:00 14 1.2 17.2 10.3 14.3 1.4 17.9 10.7 353 5 355 305 -11.9 0 -11.7 -12.1 11/24/2005 11:00:00 14.6 1.5 18.3 10.3 14.9 1.6 18.3 10.7 349 5 351 305 -12.1 0 -11.9 -12.3 11/24/2005 11:10:00 13.1 1.6 16.4 8 13.2 1.7 17.2 8.8 348 6 348 305 -12 0 -11.7 -12.1 11/24/2005 11:20:00 13.4 1.6 17.2 9.5 13.6 1.7 18.3 9.9 348 5 350 305 -12 0 -11.7 -12.3 11/24/2005 11:30:00 13.8 1.4 16.8 9.5 13.9 1.5 16.8 10.3 343 5 343 305 -12 0 -11.7 -12.1 11/24/2005 11:40:00 13.3 1.4 17.6 10.3 13.6 1.4 17.2 10.3 346 6 356 305 -12 0 -11.7 -12.1 11/24/2005 11:50:00 12.1 1.5 15.3 8.8 12.3 1.5 16.1 8 346 5 333 305 -12 0 -11.7 -12.1 11/24/2005 12:00:00 11.9 1.5 15.3 8 12.1 1.6 16.1 8.8 344 5 341 305 -12 0 -11.7 -12.1 11/24/2005 12:10:00 13.2 1.2 16.1 9.5 13.5 1.3 16.8 9.5 342 5 346 305 -12 0 -11.9 -12.1 11/24/2005 12:20:00 12.2 1.3 15.6 9.1 12.4 1.3 15.6 8.8 342 5 344 305 -11.9 0 -11.7 -12.1 11/24/2005 12:30:00 12 1.2 14.9 8.4 12.2 1.2 15.3 8.4 340 5 337 305 -11.8 0 -11.5 -12.1 11/24/2005 12:40:00 11.6 1.2 14.1 8.4 11.6 1.2 14.1 8.8 345 6 339 305 -11.8 0 -11.5 -12.1 11/24/2005 12:50:00 12.4 1.1 14.5 8.4 12.5 1.2 15.3 9.1 341 5 337 305 -11.9 0.1 -11.5 -12.1 11/24/2005 13:00:00 12.1 1.2 15.3 8.8 12.3 1.3 15.3 9.1 343 5 341 305 -11.9 0 -11.7 -12.1 11/24/2005 13:10:00 11.8 1.3 14.9 8.4 12 1.3 15.6 8.8 340 6 343 305 -11.8 0 -11.5 -12.1 11/24/2005 13:20:00 11.2 1.1 13.7 7.6 11.3 1.2 13.7 8.4 337 5 337 305 -11.8 0 -11.5 -11.9 11/24/2005 13:30:00 10.6 1.4 13.7 6.5 10.8 1.4 14.1 7.2 341 6 346 305 -11.6 0.2 -11.3 -11.9 11/24/2005 13:40:00 10.8 1.3 13.7 6.5 10.9 1.3 14.1 6.8 338 6 330 305 -11.4 0.1 -11.1 -11.5 11/24/2005 13:50:00 10.7 1.1 13.3 7.2 10.8 1.2 13.7 8 340 6 332 305 -11.4 0.1 -10.9 -11.5 11/24/2005 14:00:00 10.5 1 13 7.6 10.6 1.1 13.3 7.6 333 5 327 305 -11.4 0.1 -11.1 -11.5 11/24/2005 14:10:00 10.4 1 12.6 7.2 10.5 1.1 13 7.6 335 5 327 305 -11.4 0.1 -11.1 -11.7 11/24/2005 14:20:00 10.6 1.2 13 8 10.7 1.2 13.7 8 336 6 334 305 -11.4 0 -11.3 -11.7 11/24/2005 14:30:00 9.6 1.2 13.3 6.8 9.7 1.3 14.1 6.8 334 6 335 305 -11.4 0 -11.1 -11.7 11/24/2005 14:40:00 10.4 1.1 13 7.6 10.7 1.2 13 7.2 334 5 330 305 -11.4 0 -11.3 -11.7 11/24/2005 14:50:00 10.8 1 13 8 10.9 1.1 13.3 8 337 5 334 305 -11.5 0 -11.3 -11.7 11/24/2005 15:00:00 10.7 1.2 13 7.6 10.9 1.2 13.7 7.6 341 5 340 305 -11.4 0 -11.3 -11.7 11/24/2005 15:10:00 11 1.1 13.3 7.6 11 1.1 13.7 8.4 341 6 339 305 -11.4 0 -11.1 -11.7 11/24/2005 15:20:00 11 1.2 13.7 8 11.2 1.2 14.1 8 341 5 346 305 -11.4 0.1 -11.1 -11.5 11/24/2005 15:30:00 10.8 1 13 8 10.9 1.2 13.3 7.6 341 5 340 305 -11.4 0 -11.1 -11.5 11/24/2005 15:40:00 10.4 1 12.6 7.6 10.6 1.1 13 7.6 346 5 350 305 -11.4 0.1 -11.1 -11.5 11/24/2005 15:50:00 10.4 1.3 13 6.8 10.4 1.3 13.7 7.6 342 5 341 305 -11.4 0 -11.1 -11.5 11/24/2005 16:00:00 9.9 1.1 12.2 6.8 10 1.2 12.6 7.6 341 6 344 305 -11.5 0 -11.1 -11.7 11/24/2005 16:10:00 10.3 1.4 13.7 6.8 10.6 1.3 13.7 8 345 6 343 305 -11.5 0 -11.3 -11.7 11/24/2005 16:20:00 9.9 1.5 13 6.8 10 1.5 13.3 7.2 343 7 348 305 -11.6 0 -11.3 -11.9 11/24/2005 16:30:00 9.9 1.1 13 7.6 10 1.1 13 7.6 343 6 331 305 -11.8 0.1 -11.5 -12.1 11/24/2005 16:40:00 10.4 1.7 14.1 6.5 10.6 1.7 14.5 7.2 346 7 347 305 -12 0 -11.7 -12.1 11/24/2005 16:50:00 10.3 1.5 14.5 7.2 10.5 1.5 14.9 7.2 345 6 330 305 -12 0 -11.7 -12.1 11/24/2005 17:00:00 9.9 1.3 14.1 6.5 10.1 1.3 15.3 7.6 346 6 351 305 -12 0 -11.7 -12.1 11/24/2005 17:10:00 9.7 1.1 12.2 6.8 9.9 1 12.2 6.8 346 6 341 305 -12 0 -11.7 -12.3 11/24/2005 17:20:00 10 1 12.2 7.2 10.3 1 13 8 353 5 348 305 -12 0 -11.7 -12.1 11/24/2005 17:30:00 9.7 1.2 12.2 6.1 10 1.1 13 6.8 349 6 346 305 -11.9 0.1 -11.7 -12.1 11/24/2005 17:40:00 9.6 1.3 12.6 6.1 9.7 1.2 13 6.1 347 6 345 305 -12 0 -11.7 -12.1 11/24/2005 17:50:00 10.1 1.1 13 6.5 10.2 1.3 13.7 6.8 350 7 350 305 -11.9 0.1 -11.7 -12.1 11/24/2005 18:00:00 9.4 1.2 12.2 6.5 9.6 1.3 12.6 6.5 343 6 339 305 -12 0 -11.7 -12.3 11/24/2005 18:10:00 9.6 1.1 12.2 7.2 9.7 1.2 12.6 6.8 345 6 343 305 -12 0 -11.7 -12.3 11/24/2005 18:20:00 10.1 1.1 12.6 6.8 10.3 1.2 13 6.8 346 5 346 305 -12.1 0 -11.9 -12.3 11/24/2005 18:30:00 9.2 1 11.5 6.8 9.3 1 12.2 6.8 349 6 341 305 -12 0 -11.7 -12.3 11/24/2005 18:40:00 9.2 1 11.1 6.1 9.3 1.1 11.8 5.3 346 6 348 305 -12 0 -11.7 -12.3 11/24/2005 18:50:00 9.5 1 11.5 7.2 9.8 1 12.2 7.2 349 5 348 305 -12.1 0 -11.7 -12.3 11/24/2005 19:00:00 9.5 1.1 12.6 6.8 9.5 1.1 12.6 7.2 348 6 356 305 -12.1 0 -11.9 -12.3 11/24/2005 19:10:00 8.7 1.2 11.5 5.3 8.8 1.3 11.5 5.7 351 6 352 305 -12.2 0 -11.9 -12.5 11/24/2005 19:20:00 8.5 1.2 11.8 4.9 8.7 1.2 12.2 5.7 346 6 355 305 -12.2 0.1 -11.9 -12.5 11/24/2005 19:30:00 9.5 1 11.8 7.2 9.7 1 12.6 7.6 347 8 336 305 -12.5 0.1 -12.1 -12.5 11/24/2005 19:40:00 8.9 1.1 12.2 5.3 9.1 1.1 12.2 6.5 347 7 334 305 -12.5 0 -12.1 -12.5 11/24/2005 19:50:00 9.9 1 12.6 7.6 9.9 1 13 7.2 350 5 342 305 -12.5 0 -12.3 -12.7 11/24/2005 20:00:00 10.5 1.2 13.3 7.2 10.6 1.3 13.7 7.2 351 5 355 305 -12.6 0 -12.5 -12.7 11/24/2005 20:10:00 10 1.5 13.7 6.5 10.1 1.6 14.1 6.5 349 6 341 305 -12.6 0 -12.5 -12.9 11/24/2005 20:20:00 9.7 1.2 12.2 6.5 9.8 1.2 12.6 6.8 348 6 350 305 -12.6 0 -12.5 -12.9 11/24/2005 20:30:00 9.5 1.1 12.2 7.2 9.6 1.2 12.2 6.5 347 6 332 305 -12.6 0 -12.3 -12.9 11/24/2005 20:40:00 9.8 1.4 13.3 6.8 9.9 1.4 13 6.5 349 6 352 305 -12.6 0 -12.3 -12.7 11/24/2005 20:50:00 9.2 1.2 11.8 6.5 9.3 1.1 11.8 6.8 344 6 351 305 -12.6 0 -12.3 -12.7 11/24/2005 21:00:00 9.4 1 11.8 6.5 9.4 1 11.8 6.8 344 6 343 305 -12.6 0 -12.3 -12.7 11/24/2005 21:10:00 9.9 1.3 12.6 7.2 10 1.5 13 6.8 346 5 352 305 -12.6 0 -12.3 -12.7 11/24/2005 21:20:00 9.2 1.5 12.2 6.5 9.5 1.7 13 5.7 347 6 340 305 -12.5 0 -12.1 -12.5 11/24/2005 21:30:00 9.8 1 11.8 6.8 10 1.1 12.2 6.5 345 5 347 305 -12.3 0 -12.1 -12.5 11/24/2005 21:40:00 8.6 1.1 11.1 5.7 8.8 1.2 11.5 5.7 340 6 341 305 -12.3 0 -12.1 -12.5 11/24/2005 21:50:00 8.2 1 10.3 4.9 8.3 1 10.3 5.7 341 8 335 305 -12.3 0 -12.1 -12.5 11/24/2005 22:00:00 8.5 1 10.7 5.7 8.6 1.1 11.1 5.7 338 6 328 305 -12.3 0 -12.1 -12.5 11/24/2005 22:10:00 9.2 0.9 11.8 6.8 9.3 0.9 11.5 6.8 344 6 355 305 -12.2 0 -12.1 -12.5 11/24/2005 22:20:00 9.6 1.2 11.8 6.5 9.8 1.2 12.6 6.8 344 4 345 305 -12.3 0 -11.9 -12.5 11/24/2005 22:30:00 9.2 1 11.1 6.5 9.3 1.1 11.8 6.5 348 5 350 305 -12.3 0 -12.1 -12.5 11/24/2005 22:40:00 8.6 1 10.7 6.1 8.9 1 11.1 6.5 348 4 349 305 -12.2 0 -12.1 -12.5 11/24/2005 22:50:00 7.5 1 9.5 5.3 7.7 0.9 9.9 5.7 345 5 341 305 -12.2 0 -11.9 -12.5 11/24/2005 23:00:00 7 1 9.5 4.9 7.2 1 9.1 4.6 344 7 330 305 -12 0 -11.7 -12.1 11/24/2005 23:10:00 7.6 0.9 9.9 5.7 7.7 0.8 9.9 5.3 346 6 337 305 -12 0 -11.7 -12.1 11/24/2005 23:20:00 9 1.1 11.5 6.1 9.3 1.2 11.5 6.5 345 6 348 305 -12.1 0 -11.9 -12.3 11/24/2005 23:30:00 7.9 1.1 9.9 4.9 8.1 1.1 10.7 5.3 343 6 351 305 -12.2 0 -11.9 -12.5 11/24/2005 23:40:00 8.3 1.1 10.7 5.3 8.5 1.1 11.5 5.7 347 7 349 305 -12.2 0 -11.9 -12.5 11/24/2005 23:50:00 8.6 1 11.1 5.3 8.7 1 11.1 5.3 348 5 349 305 -12.4 0.1 -12.1 -12.5 11/25/2005 00:00:00 8.3 0.9 10.7 6.1 8.5 1 10.7 6.5 348 6 348 305 -12.4 0 -12.1 -12.5 11/25/2005 00:10:00 8.6 1.1 11.1 5.7 8.7 1.2 11.5 5.7 346 6 347 305 -12.3 0 -12.1 -12.5 11/25/2005 00:20:00 8.3 0.8 9.9 5.7 8.3 0.8 9.9 5.7 343 5 336 305 -12.3 0 -12.1 -12.5 11/25/2005 00:30:00 8.8 1.1 11.1 5.3 8.9 1.2 11.8 5.7 346 5 347 305 -12.4 0 -12.1 -12.5 11/25/2005 00:40:00 8.9 1 11.1 6.1 9.2 1 11.5 6.5 346 4 348 305 -12.3 0 -12.1 -12.5 11/25/2005 00:50:00 8 0.9 9.9 5.7 8.3 0.9 10.3 5.7 351 5 356 305 -12.3 0.1 -12.1 -12.5 11/25/2005 01:00:00 8.3 1 10.3 5.7 8.4 1 10.7 6.1 346 5 339 305 -12.2 0 -11.9 -12.5 11/25/2005 01:10:00 8.4 0.8 10.7 6.5 8.5 0.8 10.7 6.5 351 6 348 305 -12.2 0 -11.9 -12.5 11/25/2005 01:20:00 7.1 1.1 9.1 4.6 7.2 1 9.5 4.9 350 8 341 305 -12.2 0 -12.1 -12.5 11/25/2005 01:30:00 8 0.8 10.3 5.7 8.2 0.9 10.3 5.7 348 6 350 305 -12.2 0 -11.9 -12.5 11/25/2005 01:40:00 8 0.8 9.9 5.7 8.3 0.8 9.9 6.1 348 5 358 305 -12 0 -11.7 -12.3 11/25/2005 01:50:00 7.7 0.7 9.5 5.7 7.9 0.8 9.9 6.1 345 5 345 305 -12 0 -11.7 -12.3 11/25/2005 02:00:00 7.6 0.9 10.3 4.9 7.7 0.9 9.9 5.3 349 5 347 305 -12 0 -11.7 -12.3 11/25/2005 02:10:00 7 0.8 9.1 5.3 7.3 0.8 9.1 5.3 349 6 349 305 -12.1 0 -11.7 -12.3 11/25/2005 02:20:00 7.7 0.7 9.5 5.7 7.8 0.8 9.5 5.7 348 5 357 305 -12.1 0 -11.9 -12.5 11/25/2005 02:30:00 7.1 1 8.8 4.6 7.3 1 9.1 4.9 355 5 356 305 -12.2 0 -11.9 -12.5 11/25/2005 02:40:00 7.2 1 9.5 4.6 7.4 0.9 9.5 5.3 352 7 5 305 -12.1 0.1 -11.9 -12.5 11/25/2005 02:50:00 6.7 0.8 8.4 4.9 6.8 0.8 8.8 4.9 354 6 353 305 -12.2 0 -12.1 -12.5 11/25/2005 03:00:00 6.5 0.9 8.8 4.6 6.6 0.9 9.1 4.9 343 6 349 305 -12.2 0 -11.9 -12.3 11/25/2005 03:10:00 7 1 9.1 4.9 7.1 1 9.5 4.9 345 5 346 305 -12.1 0.1 -11.7 -12.3 11/25/2005 03:20:00 7 0.8 8.4 4.9 7.1 0.8 8.8 4.6 353 5 344 305 -12 0 -11.7 -12.3 11/25/2005 03:30:00 6.1 0.9 8 3.8 6.2 0.9 8.4 3.8 352 6 346 305 -12 0 -11.7 -12.1 11/25/2005 03:40:00 5.8 1.1 9.1 3.4 5.9 1.1 8.8 3.4 349 7 341 305 -11.9 0 -11.7 -12.1 11/25/2005 03:50:00 7.3 0.9 9.1 4.9 7.4 0.9 9.5 4.6 345 6 344 305 -11.9 0.1 -11.5 -12.1 11/25/2005 04:00:00 7.5 1.1 9.9 5.3 7.7 1.1 10.3 5.7 343 7 352 305 -11.8 0 -11.7 -12.1 11/25/2005 04:10:00 7.6 0.9 9.5 5.3 7.7 0.8 9.9 5.3 348 5 348 305 -11.8 0 -11.5 -12.1 11/25/2005 04:20:00 8.2 1.1 11.5 5.7 8.4 1.1 11.1 6.1 348 5 347 305 -11.8 0 -11.5 -12.1 11/25/2005 04:30:00 8.2 0.9 11.1 6.1 8.3 1 10.7 6.1 348 6 337 305 -12 0 -11.7 -12.1 11/25/2005 04:40:00 8.2 1 11.1 6.1 8.4 1 11.1 6.1 354 6 352 305 -12 0 -11.7 -12.1 11/25/2005 04:50:00 7.9 0.7 9.9 6.1 8 0.8 9.9 6.1 357 5 353 305 -12.1 0 -11.7 -12.3 11/25/2005 05:00:00 7.5 1 9.9 4.9 7.7 1 10.3 4.9 355 5 346 305 -12.1 0 -11.9 -12.3 11/25/2005 05:10:00 8.6 1.2 11.1 6.1 8.7 1.2 11.8 6.1 358 6 355 305 -12.2 0.1 -11.9 -12.5 11/25/2005 05:20:00 8.8 1 11.5 6.5 8.8 1.1 11.5 6.1 359 6 359 305 -12.3 0 -12.1 -12.5 11/25/2005 05:30:00 10 1.2 12.2 6.1 9.8 1.3 12.2 6.1 1 5 357 305 -12.2 0 -11.9 -12.5 11/25/2005 05:40:00 9.9 1.1 12.2 7.2 9.8 1.2 12.6 6.8 4 6 4 305 -12 0 -11.7 -12.1 11/25/2005 05:50:00 9.2 1 11.5 6.1 9.1 1.1 11.8 6.1 8 6 7 305 -12 0 -11.7 -12.1 11/25/2005 06:00:00 8.3 0.9 10.7 6.1 8.3 0.9 11.1 5.7 358 5 354 305 -11.9 0.1 -11.7 -12.1 11/25/2005 06:10:00 9.1 0.9 11.5 7.2 9.3 1 11.5 6.5 349 5 346 305 -11.9 0.1 -11.5 -12.1 11/25/2005 06:20:00 8.9 0.9 10.7 6.5 9.1 0.9 11.1 7.2 355 6 358 305 -12 0 -11.7 -12.1 11/25/2005 06:30:00 9.4 1 11.5 6.5 9.6 1 12.2 6.8 355 5 350 305 -12 0 -11.7 -12.1 11/25/2005 06:40:00 9.4 1 11.8 6.5 9.5 1 11.8 6.5 351 6 356 305 -12 0 -11.7 -12.1 11/25/2005 06:50:00 9.1 1 11.5 6.8 9.3 1 11.8 7.2 354 5 356 305 -12 0 -11.7 -12.1 11/25/2005 07:00:00 9.6 0.8 11.5 7.2 9.5 1 11.8 6.5 359 4 359 305 -12.1 0 -11.9 -12.3 11/25/2005 07:10:00 9.5 0.9 11.8 6.8 9.6 1 12.2 6.8 354 4 358 305 -12.2 0 -11.9 -12.3 11/25/2005 07:20:00 8.6 1 11.1 6.1 8.6 1 10.7 6.1 356 6 357 305 -12.1 0 -11.9 -12.3 11/25/2005 07:30:00 8.6 1.1 11.1 5.3 8.7 1.1 11.5 5.7 356 5 359 305 -12.2 0 -12.1 -12.5 11/25/2005 07:40:00 7.8 0.9 9.5 5.7 7.9 0.9 9.9 6.1 354 5 355 305 -12.1 0 -11.7 -12.3 11/25/2005 07:50:00 8.2 1 9.9 5.3 8.4 1 10.7 5.7 350 6 356 305 -12.1 0 -11.9 -12.3 11/25/2005 08:00:00 8.7 1 10.7 5.7 8.8 1 11.5 6.1 349 5 354 305 -12.1 0 -12.1 -12.3 11/25/2005 08:10:00 7.9 0.8 10.3 6.1 8.1 0.8 10.7 6.1 351 4 346 305 -12.1 0 -11.9 -12.3 11/25/2005 08:20:00 7.9 0.7 9.5 6.1 8.1 0.7 9.9 5.7 350 5 345 305 -12.1 0 -11.7 -12.3 11/25/2005 08:30:00 8.1 0.8 10.3 5.7 8.2 0.8 10.3 6.1 348 6 358 305 -12 0 -11.7 -12.1 11/25/2005 08:40:00 8.5 0.9 10.7 6.5 8.6 1 10.7 6.5 352 5 347 305 -12 0 -11.7 -12.1 11/25/2005 08:50:00 8.6 1.1 11.1 5.7 8.7 1.2 11.1 6.1 353 5 354 305 -12 0 -11.7 -12.1 11/25/2005 09:00:00 9 1 10.7 6.5 9.1 1.1 11.5 6.1 354 5 356 305 -11.9 0.1 -11.5 -12.1 11/25/2005 09:10:00 8.3 0.9 9.9 6.1 8.3 0.9 10.3 5.7 357 6 354 305 -11.9 0.1 -11.7 -12.1 11/25/2005 09:20:00 8.5 0.8 10.3 6.1 8.7 0.8 10.7 6.5 357 6 357 305 -11.9 0.1 -11.5 -12.1 11/25/2005 09:30:00 7.8 0.9 9.9 5.7 7.9 1 9.9 6.1 354 5 355 305 -11.9 0 -11.7 -12.1 11/25/2005 09:40:00 8.8 1 10.7 5.3 8.8 1.1 11.5 5.3 348 6 337 305 -11.9 0.1 -11.7 -12.1 11/25/2005 09:50:00 8.2 0.9 10.3 5.7 8.3 1 10.3 5.7 347 5 343 305 -12 0 -11.7 -12.1 11/25/2005 10:00:00 7.6 1 9.9 4.9 7.7 1 10.3 5.7 349 7 346 305 -12 0 -11.7 -12.3 11/25/2005 10:10:00 5.6 1.1 8 3.4 5.7 1 8 3.8 348 7 358 305 -12.2 0 -11.9 -12.5 11/25/2005 10:20:00 7.3 1.1 9.5 4.6 7.5 1.1 9.9 4.9 357 6 356 305 -12 0 -11.7 -12.1 11/25/2005 10:30:00 8.1 0.9 9.9 5.3 8.3 1 10.3 5.7 356 4 354 305 -11.9 0 -11.7 -12.1 11/25/2005 10:40:00 7.2 0.7 8.8 5.3 7.3 0.7 8.8 5.3 356 5 357 305 -12 0 -11.7 -12.1 11/25/2005 10:50:00 6.7 0.8 8.4 4.6 6.8 0.9 8.8 4.6 348 6 355 305 -12 0 -11.7 -12.1 11/25/2005 11:00:00 6.7 0.7 8.4 5.3 6.9 0.8 8.8 4.9 2 7 350 305 -12 0 -11.7 -12.1 11/25/2005 11:10:00 5.8 0.9 7.6 3.8 5.8 0.9 8 3.8 4 8 358 305 -12 0 -11.7 -12.3 11/25/2005 11:20:00 5.8 0.5 7.2 4.2 6 0.5 7.2 4.6 358 4 359 305 -12 0 -11.9 -12.3 11/25/2005 11:30:00 5.7 0.6 6.8 4.2 5.8 0.6 7.2 4.2 1 5 0 305 -11.9 0 -11.7 -12.1 11/25/2005 11:40:00 5.8 0.7 7.2 3.8 5.8 0.7 7.2 4.2 5 5 3 305 -11.8 0.1 -11.5 -12.1 11/25/2005 11:50:00 4.9 0.9 6.8 3 4.9 1 7.2 3 4 7 358 305 -11.9 0.1 -11.5 -12.1 11/25/2005 12:00:00 5.6 0.7 7.2 3.8 5.8 0.7 7.2 3.8 1 6 359 305 -11.9 0.1 -11.7 -12.1 11/25/2005 12:10:00 5.6 1.1 7.6 3 5.7 1 7.6 3.4 10 6 10 305 -12 0 -11.5 -12.1 11/25/2005 12:20:00 6 0.5 7.2 4.6 6.1 0.6 7.6 4.9 17 5 18 305 -12 0 -11.7 -12.3 11/25/2005 12:30:00 5.5 0.7 7.2 3.8 5.5 0.7 7.2 4.2 17 7 16 305 -12 0 -11.7 -12.3 11/25/2005 12:40:00 6.2 0.7 7.6 4.2 6.3 0.7 7.6 4.2 7 4 6 305 -11.9 0.1 -11.5 -12.3 11/25/2005 12:50:00 6.1 0.6 7.6 4.9 6.3 0.5 7.6 4.9 12 5 4 305 -11.9 0.1 -11.5 -12.1 11/25/2005 13:00:00 5.9 0.6 7.2 4.2 6 0.6 7.2 4.6 13 6 9 305 -11.9 0.1 -11.5 -12.1 11/25/2005 13:10:00 5.7 0.7 7.2 3.8 5.7 0.7 7.2 3.4 12 5 15 305 -11.8 0.1 -11.5 -12.1 11/25/2005 13:20:00 5.9 0.5 7.2 4.6 6 0.5 7.2 4.9 14 4 15 305 -11.7 0.1 -11.5 -11.9 11/25/2005 13:30:00 6 0.5 7.2 4.6 6.2 0.5 7.6 4.6 15 4 10 305 -11.6 0.1 -11.1 -11.9 11/25/2005 13:40:00 5.1 0.5 6.5 3.8 5.2 0.6 6.5 3.8 22 5 20 305 -11.3 0.1 -10.9 -11.5 11/25/2005 13:50:00 5.4 0.6 6.8 4.2 5.5 0.6 7.2 4.2 16 5 14 305 -11.1 0.1 -10.9 -11.5 11/25/2005 14:00:00 5.6 0.7 6.8 3.4 5.7 0.8 6.8 3.8 14 7 23 305 -11.2 0.1 -10.9 -11.5 11/25/2005 14:10:00 5.4 0.8 6.8 3 5.5 0.8 7.2 3.4 7 4 8 305 -11.1 0.1 -10.9 -11.3 11/25/2005 14:20:00 4.7 0.6 6.5 3.4 4.9 0.6 6.5 3.4 14 4 13 305 -11.1 0.1 -10.9 -11.3 11/25/2005 14:30:00 6.3 0.5 7.2 4.9 6.5 0.5 7.6 4.9 12 3 14 305 -11.2 0 -10.9 -11.3 11/25/2005 14:40:00 5.4 0.5 6.5 3.8 5.6 0.5 6.8 4.2 22 6 13 305 -11.2 0.1 -10.9 -11.5 11/25/2005 14:50:00 4.8 0.5 6.1 3.8 5 0.5 6.1 3.8 15 7 22 305 -11.2 0 -10.9 -11.5 11/25/2005 15:00:00 4.4 0.5 5.7 3.4 4.5 0.5 5.7 3 19 5 19 305 -11.1 0 -10.7 -11.3 11/25/2005 15:10:00 4.4 0.6 5.7 2.6 4.6 0.6 6.1 3 19 6 23 305 -11 0 -10.7 -11.3 11/25/2005 15:20:00 4.6 0.5 5.7 3.4 4.8 0.5 6.1 3.4 11 6 8 305 -11 0.1 -10.7 -11.3 11/25/2005 15:30:00 4.6 0.5 6.1 3.4 4.7 0.5 6.1 3.4 18 5 16 305 -11.1 0.1 -10.7 -11.5 11/25/2005 15:40:00 4.4 0.5 5.7 3 4.6 0.4 5.7 3.4 16 5 19 305 -11.2 0.1 -10.9 -11.5 11/25/2005 15:50:00 4.6 0.5 5.7 3 4.8 0.6 6.1 3.4 12 5 10 305 -11.1 0 -10.7 -11.3 11/25/2005 16:00:00 4.5 0.5 5.7 3.4 4.7 0.5 6.1 3.4 17 4 20 305 -11.2 0.1 -10.9 -11.5 11/25/2005 16:10:00 4.4 0.5 5.3 3 4.5 0.5 5.7 3 15 5 13 305 -11.2 0.1 -10.9 -11.3 11/25/2005 16:20:00 4 0.4 4.9 2.6 4.2 0.4 5.3 3.4 19 5 21 305 -11.2 0.1 -10.9 -11.5 11/25/2005 16:30:00 3.6 0.5 4.9 2.3 3.8 0.5 4.9 2.6 25 6 24 305 -11.4 0.1 -10.9 -11.7 11/25/2005 16:40:00 3.7 0.3 4.6 2.3 3.9 0.3 4.6 2.6 12 4 12 305 -11.5 0 -11.3 -11.7 11/25/2005 16:50:00 3.5 0.3 4.6 2.6 3.7 0.3 4.6 3 26 8 34 305 -11.5 0 -11.3 -11.7 11/25/2005 17:00:00 3.4 0.3 4.2 2.6 3.5 0.3 4.6 2.6 22 7 34 305 -11.6 0 -11.3 -11.9 11/25/2005 17:10:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 46 10 48 305 -11.8 0.2 -11.3 -12.5 11/25/2005 17:20:00 3.3 0.3 4.2 2.3 3.3 0.4 4.2 2.3 45 7 48 305 -12.5 0.1 -12.1 -12.7 11/25/2005 17:30:00 2.9 0.4 3.8 1.9 3 0.4 3.8 2.3 49 6 50 305 -12.1 0 -11.9 -12.5 11/25/2005 17:40:00 2.2 0.2 2.6 1.5 2.3 0.2 3 1.9 41 6 32 305 -11.9 0 -11.7 -12.1 11/25/2005 17:50:00 2.1 0.3 3 1.5 2.4 0.3 3 1.9 58 12 76 305 -12 0.1 -11.7 -12.3 11/25/2005 18:00:00 2.1 0.6 3.4 0.7 2.2 0.5 3.4 1.1 54 15 70 305 -12.5 0.2 -12.1 -12.9 11/25/2005 18:10:00 0.5 0.4 2.3 0.4 0.8 0.5 2.3 0.4 33 22 51 305 -12.3 0.2 -11.9 -12.9 11/25/2005 18:20:00 1.4 0.8 3 0.4 2 0.8 3.4 0.4 184 36 202 305 -12.8 0 -12.5 -13.1 11/25/2005 18:30:00 0.4 0.1 1.1 0.4 0.9 0.4 1.9 0.4 193 9 189 305 -12.8 0 -12.5 -12.9 11/25/2005 18:40:00 0.8 0.3 1.5 0.4 1.5 0.3 1.9 1.1 199 4 203 305 -13 0.2 -12.5 -13.3 11/25/2005 18:50:00 1.6 0.4 2.3 0.4 1.9 0.5 2.6 1.1 188 4 186 305 -13.1 0.2 -12.7 -13.3 11/25/2005 19:00:00 1.5 0.3 2.3 0.7 2.1 0.4 2.6 1.1 194 6 196 305 -13.2 0.2 -12.5 -13.5 11/25/2005 19:10:00 0.9 0.4 1.5 0.4 1.5 0.4 2.3 0.7 182 3 179 305 -13.4 0.2 -13.1 -13.9 11/25/2005 19:20:00 0.6 0.4 1.5 0.4 0.7 0.3 1.5 0.4 195 12 210 305 -14.4 0.3 -13.7 -14.6 11/25/2005 19:30:00 0.6 0.4 1.5 0.4 0.8 0.4 1.5 0.4 207 2 210 305 -14.1 0.4 -13.7 -14.8 11/25/2005 19:40:00 0.8 0.4 1.5 0.4 1.1 0.4 1.9 0.4 196 8 192 305 -13.8 0.1 -13.5 -14.1 11/25/2005 19:50:00 0.5 0.2 1.5 0.4 0.9 0.3 1.5 0.4 176 2 184 305 -13.9 0 -13.7 -14.1 11/25/2005 20:00:00 0.4 0.1 0.7 0.4 0.9 0.2 1.5 0.4 175 0 176 305 -14.3 0.2 -13.7 -14.6 11/25/2005 20:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 175 0 305 305 -14.7 0 -14.4 -15 11/25/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 175 0 305 305 -14.8 0.1 -14.4 -15 11/25/2005 20:30:00 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 166 12 177 305 -14.2 0 -13.9 -14.4 11/25/2005 20:40:00 0.9 0.5 1.9 0.4 1.6 0.8 3 0.4 175 4 176 305 -13.5 0.1 -13.3 -14.1 11/25/2005 20:50:00 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 168 21 157 305 -13.7 0.2 -13.3 -14.3 11/25/2005 21:00:00 1 0.5 2.3 0.4 1.4 0.5 2.3 0.4 142 7 133 305 -13.8 0.2 -13.3 -14.1 11/25/2005 21:10:00 0.8 0.6 2.6 0.4 1.4 0.5 2.6 0.4 166 15 150 305 -13.4 0.1 -13.1 -13.7 11/25/2005 21:20:00 0.4 0.2 1.1 0.4 1.1 0.3 1.9 0.4 176 6 170 305 -13.5 0.1 -13.3 -13.7 11/25/2005 21:30:00 1.1 0.3 1.9 0.4 1.4 0.3 2.3 0.7 200 2 203 305 -13.5 0.2 -13.1 -13.9 11/25/2005 21:40:00 1.4 0.5 2.3 0.4 1.5 0.4 2.3 0.7 185 7 192 305 -14 0.1 -13.7 -14.3 11/25/2005 21:50:00 1.2 0.4 1.9 0.4 1.3 0.4 2.3 0.7 186 5 189 305 -14 0 -13.7 -14.3 11/25/2005 22:00:00 1.2 0.5 2.3 0.4 1.5 0.4 2.3 0.7 182 1 182 305 -13.9 0.1 -13.5 -14.3 11/25/2005 22:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 182 0 305 305 -14 0.2 -13.7 -14.3 11/25/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 0 305 305 -14.3 0.1 -14.1 -14.6 11/25/2005 22:30:00 0.4 0.1 0.7 0.4 0.7 0.5 2.3 0.4 175 8 172 305 -14.1 0.2 -13.7 -14.6 11/25/2005 22:40:00 0.4 0.1 1.1 0.4 0.7 0.5 1.9 0.4 170 7 183 305 -13.4 0.1 -13.1 -13.7 11/25/2005 22:50:00 0.7 0.4 1.5 0.4 1.1 0.5 1.9 0.4 186 4 187 305 -13.1 0.2 -12.7 -13.5 11/25/2005 23:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 190 0 305 305 -13.3 0.1 -12.9 -13.5 11/25/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 305 305 -13.9 0.2 -13.3 -14.3 11/25/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 191 0 305 305 -13.8 0.1 -13.3 -14.3 11/25/2005 23:30:00 0.7 0.3 1.5 0.4 1.3 0.5 2.3 0.4 189 6 190 305 -13.3 0 -12.9 -13.5 11/25/2005 23:40:00 1.5 0.5 2.3 0.4 2 0.4 2.6 1.1 188 8 196 305 -13.6 0 -13.3 -13.7 11/25/2005 23:50:00 0.7 0.4 1.9 0.4 1.3 0.5 2.3 0.4 152 12 143 305 -13.5 0.1 -13.3 -13.7 11/26/2005 00:00:00 0.6 0.5 2.3 0.4 0.9 0.7 2.6 0.4 131 22 154 305 -13.6 0 -13.3 -13.9 11/26/2005 00:10:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 111 12 80 305 -13.2 0 -12.9 -13.5 11/26/2005 00:20:00 0.5 0.2 1.5 0.4 0.7 0.3 1.5 0.4 93 6 89 305 -13.6 0 -13.3 -13.9 11/26/2005 00:30:00 0.4 0.2 1.5 0.4 0.7 0.3 1.5 0.4 94 1 93 305 -13.8 0 -13.7 -14.1 11/26/2005 00:40:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 93 0 93 305 -14.2 0 -13.7 -14.3 11/26/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 305 305 -14.3 0 -14.3 -14.4 11/26/2005 01:00:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 122 22 113 305 -14 0.2 -13.7 -14.4 11/26/2005 01:10:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 117 6 116 305 -13.6 0.1 -13.5 -14.1 11/26/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 121 0 305 305 -13.1 0.1 -12.9 -13.7 11/26/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 121 0 305 305 -12.9 0.2 -12.5 -13.3 11/26/2005 01:40:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 121 0 305 305 -13.4 0 -13.1 -13.7 11/26/2005 01:50:00 0.6 0.5 2.3 0.4 0.8 0.6 2.3 0.4 104 6 108 305 -14 0.2 -13.5 -14.3 11/26/2005 02:00:00 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 135 32 88 305 -13.5 0.3 -12.9 -13.9 11/26/2005 02:10:00 0.8 0.7 3 0.4 1 0.9 3.8 0.4 146 28 100 305 -12.7 0.3 -12.1 -13.1 11/26/2005 02:20:00 1.1 0.7 3.8 0.4 1 0.5 2.6 0.4 107 56 88 305 -12.5 0 -12.3 -12.9 11/26/2005 02:30:00 2.5 1.1 4.9 0.4 2.6 1.2 5.3 0.4 129 19 118 305 -12.8 0.1 -12.5 -13.1 11/26/2005 02:40:00 4.2 0.7 5.7 2.3 4.7 0.7 6.1 2.6 126 11 129 305 -12.5 0 -12.3 -12.7 11/26/2005 02:50:00 3.4 1 5.3 1.1 4.3 0.8 6.1 2.3 124 13 133 305 -12.4 0.1 -12.1 -12.5 11/26/2005 03:00:00 4.1 0.7 5.3 2.3 4.5 0.7 5.7 2.3 121 11 130 305 -12.2 0 -11.9 -12.5 11/26/2005 03:10:00 5.2 0.5 6.5 3.4 5.5 0.5 6.5 3.8 123 8 128 305 -12.2 0 -11.9 -12.5 11/26/2005 03:20:00 4.4 1 6.5 1.9 4.4 1 6.5 1.9 117 13 105 305 -12 0.1 -11.5 -12.3 11/26/2005 03:30:00 4.6 0.7 6.1 2.3 4.8 0.7 6.1 2.3 120 8 124 305 -11.9 0.1 -11.5 -12.1 11/26/2005 03:40:00 4.8 1 6.5 2.6 5 1 6.5 2.3 121 10 129 305 -12 0 -11.7 -12.1 11/26/2005 03:50:00 4.7 0.8 6.5 1.9 4.9 0.8 6.8 2.6 125 9 118 305 -11.9 0.1 -11.5 -12.1 11/26/2005 04:00:00 4.7 0.5 5.7 3.4 5 0.6 6.1 3 126 9 124 305 -12 0 -11.7 -12.3 11/26/2005 04:10:00 3.9 0.9 6.1 1.1 4.2 0.8 5.7 2.3 118 16 93 305 -12 0.1 -11.5 -12.3 11/26/2005 04:20:00 4.5 0.7 6.1 2.6 4.6 0.6 6.1 2.6 113 8 111 305 -12 0 -11.7 -12.3 11/26/2005 04:30:00 5.1 1 6.8 2.3 5.1 1.1 6.8 2.6 114 8 108 305 -12 0.1 -11.7 -12.3 11/26/2005 04:40:00 5.6 0.6 6.8 3.8 5.7 0.6 6.8 3.4 119 6 115 305 -12 0 -11.7 -12.3 11/26/2005 04:50:00 5.6 0.4 6.8 4.6 5.7 0.4 7.2 4.9 120 6 125 305 -12.2 0 -11.9 -12.5 11/26/2005 05:00:00 5.3 0.5 6.5 4.2 5.5 0.5 6.8 4.6 121 5 123 305 -12 0.1 -11.7 -12.3 11/26/2005 05:10:00 6.2 0.5 7.2 4.2 6.2 0.4 7.6 5.3 120 4 119 305 -12 0 -11.7 -12.1 11/26/2005 05:20:00 6 0.4 7.2 4.9 5.9 0.4 6.8 4.9 115 4 113 305 -11.9 0.1 -11.5 -12.1 11/26/2005 05:30:00 5.7 0.4 7.2 4.6 5.7 0.4 6.5 4.9 112 4 116 305 -11.8 0 -11.5 -12.1 11/26/2005 05:40:00 6.1 0.3 6.8 5.3 6.1 0.3 6.8 5.3 115 3 114 305 -11.6 0 -11.3 -11.7 11/26/2005 05:50:00 6.8 0.3 7.2 5.7 6.5 0.3 7.2 5.3 111 3 111 305 -11.7 0.1 -11.3 -12.1 11/26/2005 06:00:00 6.6 0.4 7.6 5.3 6.5 0.4 7.6 5.7 113 3 111 305 -11.9 0.1 -11.5 -12.1 11/26/2005 06:10:00 6.8 0.5 8.4 5.3 6.6 0.5 8 5.3 112 3 113 305 -11.7 0 -11.3 -12.1 11/26/2005 06:20:00 7.6 0.5 8.4 6.1 7.4 0.5 8.4 6.1 111 3 111 305 -11.5 0 -11.3 -11.7 11/26/2005 06:30:00 7.4 0.4 8.4 6.5 7.1 0.4 8 6.1 107 3 113 305 -11.7 0.1 -11.3 -12.1 11/26/2005 06:40:00 7.8 0.5 9.1 6.5 7.3 0.5 8.8 6.1 105 3 102 305 -11.8 0.1 -11.5 -12.1 11/26/2005 06:50:00 7.4 0.5 8.8 6.5 6.9 0.5 8 5.7 102 3 105 305 -11.9 0.1 -11.5 -12.1 11/26/2005 07:00:00 7.6 0.6 9.5 6.1 6.9 0.6 8.8 5.7 98 4 94 305 -12 0 -11.7 -12.1 11/26/2005 07:10:00 7.6 0.7 9.1 5.7 6.8 0.6 8.4 5.3 92 4 94 305 -12 0.1 -11.7 -12.3 11/26/2005 07:20:00 7.7 1 9.5 4.6 7 0.9 8.8 3.8 92 7 99 305 -11.9 0.1 -11.5 -12.1 11/26/2005 07:30:00 8.1 0.8 9.9 5.7 7.4 0.8 9.5 4.9 91 7 101 305 -11.9 0.1 -11.5 -12.1 11/26/2005 07:40:00 8.2 1 10.3 5.7 7.5 0.9 9.9 4.9 93 6 96 305 -11.8 0.1 -11.5 -12.1 11/26/2005 07:50:00 8.8 0.6 10.3 6.8 8 0.6 9.9 6.5 97 5 97 305 -11.7 0 -11.3 -11.9 11/26/2005 08:00:00 9.2 0.6 10.7 7.2 8.5 0.6 9.9 6.5 100 4 102 305 -11.5 0 -11.1 -11.7 11/26/2005 08:10:00 9.1 0.6 10.7 7.2 8.4 0.6 9.9 6.5 101 4 97 305 -11.5 0 -11.1 -11.7 11/26/2005 08:20:00 9.5 0.6 11.1 8 8.8 0.5 10.3 7.2 102 4 102 305 -11.4 0 -10.9 -11.7 11/26/2005 08:30:00 9 0.6 10.3 6.8 8.4 0.6 10.3 6.8 103 4 110 305 -11.4 0.1 -10.9 -11.5 11/26/2005 08:40:00 9.3 0.6 11.1 7.6 8.7 0.6 10.3 7.2 102 4 109 305 -11.4 0 -10.9 -11.5 11/26/2005 08:50:00 9.1 0.7 10.7 7.2 8.6 0.7 10.3 6.5 104 5 106 305 -11.4 0.1 -10.9 -11.5 11/26/2005 09:00:00 9.1 0.8 11.1 6.8 8.7 0.8 11.1 6.8 106 5 105 305 -11.4 0 -10.9 -11.5 11/26/2005 09:10:00 9 0.7 10.7 7.2 8.6 0.6 10.3 7.2 107 5 117 305 -11.4 0 -10.9 -11.5 11/26/2005 09:20:00 8.7 0.7 10.7 6.8 8.3 0.7 10.3 6.5 106 5 108 305 -11.3 0.1 -10.9 -11.5 11/26/2005 09:30:00 8.2 0.8 10.3 6.1 7.8 0.7 9.5 6.1 107 6 101 305 -11.4 0 -10.9 -11.5 11/26/2005 09:40:00 7.9 0.8 9.9 5.3 7.5 0.8 9.5 4.9 105 7 105 305 -11.4 0.1 -10.9 -11.5 11/26/2005 09:50:00 7.2 0.8 8.8 4.6 6.8 0.8 8.4 4.9 108 6 94 305 -11.4 0.1 -10.9 -11.5 11/26/2005 10:00:00 6 0.9 8.4 4.2 5.7 0.8 8 3.8 106 9 108 305 -11.4 0.1 -10.9 -11.7 11/26/2005 10:10:00 5.7 0.8 7.6 3.4 5.4 0.7 7.2 3.8 104 12 113 305 -11.4 0.1 -11.1 -11.7 11/26/2005 10:20:00 4.3 1.2 7.2 1.1 4.2 1.1 6.8 1.5 104 13 84 305 -11.4 0.1 -10.9 -11.5 11/26/2005 10:30:00 3.9 1.3 7.6 1.1 3.8 1.2 7.2 1.1 95 19 90 305 -11.4 0.1 -10.9 -11.7 11/26/2005 10:40:00 4.4 1.2 7.6 1.5 4.1 1.2 6.8 1.5 89 19 95 305 -11.3 0.1 -10.9 -11.7 11/26/2005 10:50:00 5.8 1.4 9.9 2.3 5.4 1.3 8.8 2.3 92 17 93 305 -11.4 0.1 -10.9 -11.5 11/26/2005 11:00:00 6.9 1.1 10.3 3.8 6.5 1 9.5 4.2 93 12 73 305 -11.3 0.1 -10.9 -11.5 11/26/2005 11:10:00 7 1.3 10.3 3.8 6.7 1.3 11.1 3.8 90 14 96 305 -11.2 0.1 -10.9 -11.5 11/26/2005 11:20:00 7.3 1.4 10.7 3.4 7 1.3 10.3 3 99 13 98 305 -11.3 0.1 -10.9 -11.5 11/26/2005 11:30:00 7.5 1.3 12.2 3.8 7 1.2 9.9 4.2 98 10 97 305 -11.4 0.1 -10.9 -11.5 11/26/2005 11:40:00 6.4 1.3 10.7 3 6 1.2 9.1 3 94 13 78 305 -11.4 0.1 -10.9 -11.7 11/26/2005 11:50:00 6.1 1.2 9.5 3 5.8 1.2 8.8 3 97 14 104 305 -11.4 0.1 -10.9 -11.5 11/26/2005 12:00:00 5.5 1.2 8.8 3 5.4 1 8.4 3.4 94 14 90 305 -11.5 0 -11.3 -11.7 11/26/2005 12:10:00 5.1 1.1 8.8 2.3 4.8 1.1 7.2 2.3 93 17 117 305 -11.5 0.1 -11.1 -11.7 11/26/2005 12:20:00 5.1 1.3 8.4 1.9 5 1.2 8.4 2.3 91 18 101 305 -11.3 0.1 -10.9 -11.5 11/26/2005 12:30:00 4.9 1.7 9.9 1.1 4.7 1.6 8.4 1.5 90 20 72 305 -11.1 0.1 -10.7 -11.3 11/26/2005 12:40:00 4.2 1.2 7.6 1.1 4 1.1 6.8 1.1 92 22 82 305 -11.2 0.1 -10.9 -11.5 11/26/2005 12:50:00 3.4 1.1 6.8 1.5 3.2 1 7.6 1.1 88 20 123 305 -11.2 0.1 -10.9 -11.5 11/26/2005 13:00:00 4.1 1.3 7.6 1.1 3.9 1.2 6.8 1.1 78 19 96 305 -11.1 0.1 -10.9 -11.3 11/26/2005 13:10:00 3.3 1.2 6.8 0.7 3.1 1.1 6.1 0.7 81 17 96 305 -11.1 0.1 -10.7 -11.3 11/26/2005 13:20:00 4.2 1 6.8 1.9 4 1 6.8 1.1 77 18 65 305 -11 0 -10.4 -11.3 11/26/2005 13:30:00 4.5 1 7.6 2.3 4.3 1 6.8 1.9 79 17 74 305 -10.9 0 -10.4 -10.9 11/26/2005 13:40:00 5.7 1.4 9.9 3 5.6 1.3 9.1 3 74 17 65 305 -10.6 0 -10 -10.9 11/26/2005 13:50:00 5 1.5 9.1 1.9 4.9 1.5 8.8 1.5 77 20 78 305 -10.4 0 -10 -10.7 11/26/2005 14:00:00 5.6 1.8 11.1 0.7 5.4 1.8 9.9 1.1 70 23 102 305 -10.2 0.1 -9.8 -10.4 11/26/2005 14:10:00 6.6 1.6 10.7 2.6 6.4 1.6 11.1 2.6 68 19 35 305 -10.1 0 -9.6 -10.4 11/26/2005 14:20:00 5.4 1.5 9.5 1.9 5.3 1.5 9.1 1.9 75 22 72 305 -9.8 0.1 -9.2 -10 11/26/2005 14:30:00 7.1 1.5 12.2 3 6.9 1.5 11.8 3.8 78 15 98 305 -9.7 0.1 -9.2 -9.8 11/26/2005 14:40:00 8.8 1.3 13 5.3 8.6 1.3 12.2 5.3 76 11 66 305 -9.7 0.1 -9.2 -10 11/26/2005 14:50:00 9.3 1.1 13 6.5 9.1 1.2 11.8 6.1 78 11 81 305 -9.9 0.1 -9.4 -10.2 11/26/2005 15:00:00 9 1.3 13 5.3 8.5 1.3 12.2 4.2 79 11 77 305 -10.1 0 -9.6 -10.2 11/26/2005 15:10:00 8.3 1.7 13.3 3.8 8 1.6 13 5.3 77 11 62 305 -10.1 0 -9.6 -10.2 11/26/2005 15:20:00 8.6 1.5 13.7 4.9 8.3 1.5 13.7 4.6 74 12 81 305 -10 0 -9.6 -10.2 11/26/2005 15:30:00 8.5 1.5 14.1 4.9 8.2 1.6 14.5 4.9 78 14 85 305 -9.9 0 -9.4 -10 11/26/2005 15:40:00 9.2 1.7 14.1 5.3 8.8 1.7 13.7 5.3 80 13 94 305 -9.8 0 -9.4 -10 11/26/2005 15:50:00 8.9 1.8 14.1 4.9 8.5 1.8 13.7 4.6 82 15 85 305 -9.8 0 -9.2 -10 11/26/2005 16:00:00 7 1.8 12.6 2.6 6.7 1.7 11.8 2.3 84 22 85 305 -9.6 0.1 -9.2 -9.8 11/26/2005 16:10:00 6 1.5 10.3 2.6 5.7 1.5 10.3 2.6 90 26 103 305 -9.3 0 -8.8 -9.4 11/26/2005 16:20:00 4.9 1.8 10.3 1.1 4.7 1.8 10.3 0.4 90 24 92 305 -9.6 0.1 -9 -9.8 11/26/2005 16:30:00 4.7 1.5 10.7 1.5 4.6 1.4 9.5 1.9 88 24 53 305 -9.7 0.1 -9.2 -9.8 11/26/2005 16:40:00 5.6 1.7 9.9 1.1 5.5 1.5 9.9 2.3 83 27 88 305 -9.6 0.1 -9.2 -9.8 11/26/2005 16:50:00 5.3 1.7 9.5 0.7 5.3 1.7 10.3 1.5 70 20 66 305 -9.6 0.1 -9.2 -9.8 11/26/2005 17:00:00 6.7 2.1 13.7 0.4 6.6 2.1 13 1.9 75 18 81 305 -9.6 0 -9.2 -9.6 11/26/2005 17:10:00 7.1 1.9 12.2 3 7.2 1.8 11.5 2.6 65 15 68 305 -9.6 0 -9.2 -9.8 11/26/2005 17:20:00 6.3 1.7 11.8 2.3 6.2 1.7 11.5 2.6 71 22 66 305 -9.6 0 -9.2 -9.8 11/26/2005 17:30:00 5.9 1.4 9.1 1.9 5.9 1.5 9.5 1.9 64 18 92 305 -9.5 0 -9 -9.6 11/26/2005 17:40:00 6.2 1.7 11.1 2.3 6.1 1.8 9.9 2.6 63 15 67 305 -9.4 0 -9 -9.6 11/26/2005 17:50:00 5.6 2 10.3 1.1 5.7 1.9 10.3 1.5 64 22 75 305 -9.4 0 -9 -9.6 11/26/2005 18:00:00 5.6 1.6 10.3 1.1 5.7 1.7 11.1 1.5 56 20 70 305 -9.4 0 -9 -9.6 11/26/2005 18:10:00 4.7 1.7 9.1 1.5 4.7 1.5 8 1.5 64 26 42 305 -9.4 0 -9 -9.6 11/26/2005 18:20:00 3.6 1.8 9.1 0.4 3.5 1.7 8 0.4 71 35 103 305 -9.4 0 -9 -9.6 11/26/2005 18:30:00 4.4 1.5 8.4 1.5 4.5 1.4 8 1.5 80 35 89 305 -9.2 0.1 -8.8 -9.4 11/26/2005 18:40:00 4.7 1.6 8.8 0.7 4.6 1.7 9.1 1.5 65 28 67 305 -9.1 0.1 -8.8 -9.2 11/26/2005 18:50:00 4.1 1.7 11.1 0.4 4 1.7 10.7 0.7 69 35 63 305 -9 0.1 -8.6 -9.2 11/26/2005 19:00:00 4.9 1.9 11.8 1.5 4.9 1.8 11.8 0.4 71 26 68 305 -9 0 -8.6 -9.2 11/26/2005 19:10:00 6.6 2.4 12.6 1.5 6.4 2.3 12.2 1.1 74 24 77 305 -9 0.1 -8.4 -9.2 11/26/2005 19:20:00 6.1 2.6 14.9 0.7 5.7 2.5 13.7 0.7 79 28 92 305 -9 0.1 -8.6 -9.2 11/26/2005 19:30:00 5.1 1.8 9.9 0.7 5 1.8 10.3 1.1 76 27 45 305 -9.1 0.1 -8.6 -9.2 11/26/2005 19:40:00 5.1 2.1 9.9 0.4 5 1.9 9.5 0.7 74 26 55 305 -9.1 0.1 -8.6 -9.2 11/26/2005 19:50:00 5.9 2.2 13.7 1.9 5.7 2.2 13.7 1.9 73 23 68 305 -9 0 -8.4 -9.2 11/26/2005 20:00:00 5.2 1.9 11.5 1.1 4.9 2.1 10.7 0.4 78 28 72 305 -9 0.1 -8.4 -9.2 11/26/2005 20:10:00 5 2.2 9.9 0.4 4.8 1.9 8.8 0.7 74 36 74 305 -9 0 -8.6 -9.2 11/26/2005 20:20:00 5.1 1.8 10.3 0.4 5 1.7 9.5 0.7 72 30 81 305 -8.9 0 -8.4 -9.2 11/26/2005 20:30:00 6.1 2.3 11.8 1.9 6 2.3 13.7 2.6 80 22 93 305 -8.9 0 -8.4 -9.2 11/26/2005 20:40:00 7.6 2 13.7 2.6 7.6 2.1 14.1 3.4 68 20 63 305 -8.9 0 -8.4 -9.2 11/26/2005 20:50:00 6.4 2.4 12.6 1.9 6.1 2.5 12.6 1.9 71 21 65 305 -8.9 0 -8.4 -9.2 11/26/2005 21:00:00 6.3 2 11.5 1.5 6.2 2 11.8 1.9 62 23 44 305 -8.9 0 -8.4 -9.2 11/26/2005 21:10:00 6.1 2.3 12.6 0.4 6.1 2.4 12.6 0.7 69 28 64 305 -8.8 0 -8.4 -9.2 11/26/2005 21:20:00 5.7 1.7 9.5 0.7 5.8 1.7 10.3 1.5 74 33 32 305 -9 0 -8.4 -9.2 11/26/2005 21:30:00 4.4 1.7 10.3 0.4 4.5 1.6 10.3 0.7 75 30 64 305 -8.9 0.1 -8.4 -9.2 11/26/2005 21:40:00 3.8 2.2 11.1 0.4 3.8 1.8 9.9 0.4 99 47 110 305 -9 0 -8.6 -9.2 11/26/2005 21:50:00 4.6 1.7 9.5 1.1 4.5 1.6 8.8 0.4 91 41 144 305 -9 0.1 -8.6 -9.2 11/26/2005 22:00:00 5.8 2.3 12.6 1.1 5.6 2.3 12.2 0.7 84 33 114 305 -9 0 -8.6 -9.2 11/26/2005 22:10:00 5.7 1.7 11.8 2.6 5.5 1.7 11.8 1.9 91 32 64 305 -9 0.1 -8.6 -9.2 11/26/2005 22:20:00 6.3 2.3 13 2.3 6.1 2.3 11.5 1.9 81 30 90 305 -8.9 0 -8.6 -9.2 11/26/2005 22:30:00 8.7 3.3 16.8 1.5 8.6 3.2 16.4 2.3 67 19 69 305 -8.9 0.1 -8.4 -9.2 11/26/2005 22:40:00 8.7 2.6 15.3 2.3 8.6 2.7 15.3 2.6 72 23 85 305 -9 0.1 -8.6 -9.2 11/26/2005 22:50:00 7.9 2.6 16.4 1.9 7.9 2.6 14.5 1.5 66 23 54 305 -8.9 0.1 -8.4 -9.2 11/26/2005 23:00:00 8.2 2.4 14.5 2.3 8.2 2.5 14.9 3 66 21 77 305 -8.9 0.1 -8.6 -9.2 11/26/2005 23:10:00 6.5 2.2 14.5 1.5 6.4 2.2 14.9 1.5 59 20 70 305 -9 0 -8.4 -9.2 11/26/2005 23:20:00 5.1 2.2 13 0.7 5.2 2 11.8 1.5 83 36 97 305 -9 0 -8.6 -9.2 11/26/2005 23:30:00 4.7 1.9 10.7 1.5 4.5 1.7 9.5 1.9 89 30 74 305 -9.1 0.1 -8.6 -9.2 11/26/2005 23:40:00 7.4 1.9 11.8 1.9 7.2 2.1 11.8 2.3 68 19 47 305 -9 0.1 -8.6 -9.2 11/26/2005 23:50:00 7.6 2.2 14.5 3.4 7.1 2.2 12.6 3.4 78 22 87 305 -9 0 -8.6 -9.2 11/27/2005 00:00:00 7.3 2.6 13.7 1.9 7.2 2.6 12.6 2.3 80 26 101 305 -9 0 -8.6 -9.2 11/27/2005 00:10:00 7.6 2.7 13 1.1 7.5 2.7 14.1 2.3 66 23 71 305 -9 0 -8.6 -9.2 11/27/2005 00:20:00 6 2.2 12.2 1.9 5.8 2.2 11.8 0.7 74 33 66 305 -8.9 0 -8.4 -9.2 11/27/2005 00:30:00 5.9 2.3 12.2 0.7 5.8 2.1 11.5 1.1 96 36 105 305 -8.9 0 -8.4 -9 11/27/2005 00:40:00 8.4 2.1 13.7 4.2 8.2 2.2 14.5 3.8 96 24 87 305 -8.8 0 -8.4 -9 11/27/2005 00:50:00 9.4 2.6 17.2 3.8 9.4 2.6 16.4 3.8 73 17 45 305 -8.7 0 -8.4 -8.8 11/27/2005 01:00:00 9.4 2.4 15.3 4.2 9.2 2.4 16.4 3.4 75 19 64 305 -8.7 0 -8.2 -8.8 11/27/2005 01:10:00 10.1 2.5 17.6 3 9.9 2.7 18.3 3.4 73 15 56 305 -8.7 0 -8.2 -8.8 11/27/2005 01:20:00 10 2 16.1 4.9 10.1 2.2 16.1 4.9 74 17 82 305 -8.7 0.1 -8.2 -8.8 11/27/2005 01:30:00 8.8 2.8 16.1 2.6 8.6 2.8 14.9 3 83 22 73 305 -8.6 0.1 -8.2 -8.8 11/27/2005 01:40:00 8 2 13.3 1.1 7.8 2.2 14.5 1.9 75 22 67 305 -8.6 0.1 -8.2 -8.8 11/27/2005 01:50:00 9.7 2.9 16.1 2.3 9.6 2.9 16.4 3 78 22 80 305 -8.5 0 -7.9 -8.6 11/27/2005 02:00:00 9.9 2.7 17.6 4.2 9.7 2.9 18.3 2.6 74 20 87 305 -8.4 0 -7.9 -8.6 11/27/2005 02:10:00 9.4 2.6 16.8 3 9.2 2.7 16.8 2.6 76 22 62 305 -8.3 0 -7.9 -8.4 11/27/2005 02:20:00 10.8 2.8 17.6 3.4 10.8 3.2 18.7 3 74 23 65 305 -8.3 0 -7.9 -8.4 11/27/2005 02:30:00 12.7 2.6 19.1 6.5 12.4 2.7 21.4 5.3 72 17 48 305 -8.3 0 -7.9 -8.4 11/27/2005 02:40:00 13.7 2.7 21.4 7.6 13.3 2.7 20.2 8.4 80 15 87 305 -8.4 0 -7.9 -8.6 11/27/2005 02:50:00 13.3 2.6 21.4 6.5 13.1 2.5 21 6.8 86 17 68 305 -8.4 0 -7.9 -8.4 11/27/2005 03:00:00 12.3 2.7 20.2 5.7 11.9 2.7 20.6 5.3 88 18 105 305 -8.4 0 -7.9 -8.6 11/27/2005 03:10:00 11.2 2.3 17.2 4.2 11 2.1 16.4 6.5 83 16 81 305 -8.3 0 -7.9 -8.4 11/27/2005 03:20:00 12 2.1 17.2 5.3 11.9 2.2 17.9 6.1 73 14 77 305 -8.3 0 -7.9 -8.4 11/27/2005 03:30:00 11.7 2.2 18.3 6.5 11.6 2.4 18.7 6.1 75 14 71 305 -8.2 0 -7.7 -8.4 11/27/2005 03:40:00 11.5 2.3 17.9 6.8 11.3 2.4 18.3 5.3 75 15 66 305 -8.2 0 -7.7 -8.4 11/27/2005 03:50:00 12.2 2.5 18.7 5.7 12.1 2.7 19.9 5.7 76 18 63 305 -8.2 0.1 -7.7 -8.2 11/27/2005 04:00:00 11.7 3.1 21.4 5.3 11.6 3.1 21.4 6.1 77 18 102 305 -8.1 0.1 -7.7 -8.2 11/27/2005 04:10:00 12.1 2.9 20.2 5.3 11.8 3.2 21 4.9 83 20 61 305 -8.2 0.1 -7.7 -8.2 11/27/2005 04:20:00 13.4 2.7 21.4 5.3 13.1 2.9 21.4 5.3 81 15 93 305 -8.1 0.1 -7.7 -8.2 11/27/2005 04:30:00 12.9 2.7 18.7 6.1 12.7 2.8 19.9 5.3 76 15 71 305 -7.9 0 -7.5 -8.2 11/27/2005 04:40:00 12.1 2.8 18.7 5.3 11.7 2.9 18.7 4.9 89 20 71 305 -7.9 0 -7.3 -7.9 11/27/2005 04:50:00 13.4 2.1 19.5 6.8 13 2.1 19.9 6.8 79 10 64 305 -7.8 0 -7.3 -7.9 11/27/2005 05:00:00 13.9 1.5 19.9 10.3 13.6 1.6 19.5 9.9 79 7 66 305 -7.7 0 -7.3 -7.9 11/27/2005 05:10:00 13.3 2.6 20.6 6.5 13.2 2.7 21 5.7 75 13 72 305 -7.7 0 -7.3 -7.9 11/27/2005 05:20:00 9.8 2.5 17.2 4.6 9.5 2.5 17.9 4.6 97 26 84 305 -7.8 0.1 -7.3 -7.9 11/27/2005 05:30:00 8.7 2.6 14.5 1.9 8.4 2.4 13.7 2.6 106 22 89 305 -8 0.1 -7.7 -8.2 11/27/2005 05:40:00 10.6 3.6 19.5 3 10.1 3.5 19.5 3 103 22 95 305 -8.3 0 -7.7 -8.6 11/27/2005 05:50:00 9.4 2.5 16.8 3.4 9 2.3 15.6 3.4 101 23 127 305 -8.4 0 -7.9 -8.6 11/27/2005 06:00:00 11 2.8 20.2 4.6 10.4 2.8 19.1 4.6 97 22 80 305 -8.4 0 -7.9 -8.6 11/27/2005 06:10:00 11.3 2.6 17.9 5.7 10.9 2.6 19.5 5.3 103 21 127 305 -8.4 0 -7.9 -8.6 11/27/2005 06:20:00 10.1 2.5 17.6 4.6 9.6 2.4 17.2 4.2 98 21 99 305 -8.4 0 -7.9 -8.6 11/27/2005 06:30:00 9.6 2.6 16.4 3.8 9.1 2.5 16.1 3.8 101 22 97 305 -8.4 0 -7.9 -8.6 11/27/2005 06:40:00 9.8 2.5 16.4 3 9.2 2.4 15.6 3.8 86 21 92 305 -8.3 0.1 -7.7 -8.4 11/27/2005 06:50:00 10.3 2.9 19.5 3.4 10.2 2.9 18.7 3.8 87 24 68 305 -8.2 0 -7.7 -8.4 11/27/2005 07:00:00 10.2 2.7 17.9 4.9 9.7 2.6 18.3 3.8 97 23 92 305 -8.2 0 -7.7 -8.4 11/27/2005 07:10:00 10.6 2.8 18.3 3.4 10.2 2.8 17.2 3.8 105 18 102 305 -8.2 0 -7.7 -8.4 11/27/2005 07:20:00 11.7 2.3 18.7 6.5 11.2 2.3 18.3 5.7 102 16 88 305 -8.2 0 -7.7 -8.4 11/27/2005 07:30:00 13.9 2.5 22.9 7.6 13.2 2.6 22.6 7.2 97 16 86 305 -8.2 0 -7.7 -8.4 11/27/2005 07:40:00 13.5 2.6 19.5 7.2 13 2.8 20.6 6.1 97 20 68 305 -8.2 0 -7.7 -8.2 11/27/2005 07:50:00 14.8 3.1 23.3 6.1 14.3 3.1 21.8 6.8 105 16 77 305 -8.1 0.1 -7.7 -8.2 11/27/2005 08:00:00 13.4 2.8 21.4 6.8 13 2.7 20.2 6.5 107 16 102 305 -8.1 0.1 -7.7 -8.2 11/27/2005 08:10:00 13.6 2.9 23.3 6.5 12.9 2.9 22.6 6.1 106 16 97 305 -8.2 0.1 -7.7 -8.2 11/27/2005 08:20:00 13.9 2.9 21.4 6.5 13.2 3.1 21.4 3.8 105 17 85 305 -8.2 0 -7.7 -8.2 11/27/2005 08:30:00 15 2.5 21.4 9.1 14.6 2.6 21.8 8.8 110 15 141 305 -8.2 0 -7.7 -8.4 11/27/2005 08:40:00 15.7 2.9 22.9 6.5 15.2 2.9 23.3 9.5 111 13 124 305 -8.2 0.1 -7.7 -8.2 11/27/2005 08:50:00 16.4 2.7 22.1 8 15.9 2.7 23.3 9.1 112 13 97 305 -8.2 0.1 -7.7 -8.2 11/27/2005 09:00:00 16.5 2.5 25.6 10.7 15.9 2.6 27.1 9.9 110 13 91 305 -8 0.1 -7.3 -8.2 11/27/2005 09:10:00 15.4 2.5 22.1 9.9 14.8 2.5 21.8 8.4 113 13 116 305 -7.8 0 -7.3 -7.9 11/27/2005 09:20:00 16.2 2.3 22.6 9.9 15.6 2.3 22.6 8.8 111 13 110 305 -7.7 0 -7.3 -7.7 11/27/2005 09:30:00 15.1 2.3 20.6 9.9 14.5 2.5 20.2 9.1 114 12 117 305 -7.6 0.1 -7.1 -7.7 11/27/2005 09:40:00 15.2 2.4 22.6 9.1 14.7 2.4 21.4 9.1 112 14 101 305 -7.4 0 -7.1 -7.7 11/27/2005 09:50:00 15.5 2.8 22.9 9.5 14.8 2.7 21.8 8.4 109 13 91 305 -7.3 0 -7.1 -7.3 11/27/2005 10:00:00 17 2.3 24.4 10.7 16.4 2.3 24 10.7 109 12 101 305 -7.2 0 -6.7 -7.3 11/27/2005 10:10:00 16.3 2.5 22.9 9.9 15.9 2.6 22.6 9.9 112 15 114 305 -7.1 0 -6.7 -7.3 11/27/2005 10:20:00 16.7 2.7 24 10.3 16.3 2.7 23.3 9.9 117 13 118 305 -7.1 0 -6.9 -7.3 11/27/2005 10:30:00 17.5 2.5 24 11.8 17 2.5 23.3 11.5 118 12 133 305 -7.2 0 -6.7 -7.3 11/27/2005 10:40:00 17.1 2.2 23.7 12.2 16.6 2.3 24.8 10.3 114 13 113 305 -7.1 0 -6.7 -7.3 11/27/2005 10:50:00 16.5 2.5 24 10.3 16.1 2.6 24 9.5 113 14 127 305 -7.2 0 -6.9 -7.5 11/27/2005 11:00:00 18 2.8 25.2 11.1 17.6 2.6 23.7 10.7 121 11 118 305 -7.4 0.1 -7.3 -7.7 11/27/2005 11:10:00 19.3 2.6 25.2 11.5 18.9 2.6 25.2 10.7 119 12 119 305 -7.6 0 -7.3 -7.7 11/27/2005 11:20:00 18.6 2.6 25.2 11.5 18.1 2.7 24.4 9.9 118 11 119 305 -7.6 0 -7.1 -7.7 11/27/2005 11:30:00 17.6 2.6 25.6 9.9 17 2.4 26.3 11.1 116 12 109 305 -7.6 0 -7.5 -7.7 11/27/2005 11:40:00 18.7 2.4 26 12.6 18.2 2.5 25.6 12.6 116 13 124 305 -7.6 0 -7.3 -7.7 11/27/2005 11:50:00 17.9 2.6 26.3 10.7 17.3 2.5 25.6 11.1 116 12 119 305 -7.5 0 -7.3 -7.7 11/27/2005 12:00:00 18.1 2.8 27.1 9.1 17.5 2.7 26.3 9.1 116 12 109 305 -7.5 0 -6.9 -7.7 11/27/2005 12:10:00 18.1 2.6 25.2 8.4 17.7 2.5 23.7 10.7 118 11 119 305 -7.5 0.1 -7.1 -7.7 11/27/2005 12:20:00 16.8 2.6 24.4 10.7 16.4 2.6 22.6 8.8 118 12 114 305 -7.4 0.1 -7.1 -7.7 11/27/2005 12:30:00 16.1 2.3 21.4 8.4 15.8 2.3 22.1 9.9 115 13 118 305 -7.5 0.1 -7.1 -7.7 11/27/2005 12:40:00 16.1 2.5 22.6 10.7 15.5 2.5 22.6 9.1 117 13 119 305 -7.4 0 -6.9 -7.7 11/27/2005 12:50:00 16 2.6 23.7 9.9 15.8 2.6 22.9 10.3 114 12 117 305 -7.4 0.1 -6.9 -7.7 11/27/2005 13:00:00 16.7 2.5 22.9 9.1 16.3 2.5 22.6 10.3 117 13 133 305 -7.4 0 -7.1 -7.7 11/27/2005 13:10:00 15.8 2.6 21.8 9.9 15.4 2.7 21.8 9.5 119 12 118 305 -7.4 0 -6.9 -7.5 11/27/2005 13:20:00 16.2 2.5 22.6 9.9 15.7 2.6 23.3 8.8 120 12 142 305 -7.4 0 -6.9 -7.5 11/27/2005 13:30:00 17.6 2.5 24.8 9.5 17.3 2.6 26 9.1 122 10 124 305 -7.4 0 -6.9 -7.5 11/27/2005 13:40:00 16.5 2.6 24.8 9.9 15.9 2.6 22.1 9.5 122 10 133 305 -7.2 0 -6.9 -7.3 11/27/2005 13:50:00 16.5 2.5 22.9 9.5 16.2 2.5 22.6 7.6 123 10 134 305 -7.2 0 -6.7 -7.3 11/27/2005 14:00:00 16.3 2.3 22.6 10.7 16.1 2.2 23.7 10.3 122 11 121 305 -7.1 0 -6.7 -7.3 11/27/2005 14:10:00 17.5 2.2 22.9 11.1 16.9 2.3 22.6 11.1 121 12 110 305 -7.1 0 -6.7 -7.3 11/27/2005 14:20:00 16.5 2.3 22.6 7.2 16.1 2.3 21.4 9.1 121 11 131 305 -7.1 0 -6.9 -7.3 11/27/2005 14:30:00 15.7 2.3 21 9.5 15.1 2.1 19.9 9.1 114 13 135 305 -7.1 0 -7.1 -7.3 11/27/2005 14:40:00 15.7 2.1 22.1 8.8 15.3 2 22.1 9.9 109 13 112 305 -7.1 0 -6.9 -7.3 11/27/2005 14:50:00 16.1 1.9 21 11.5 15.7 2.1 22.9 11.1 116 13 108 305 -7.1 0 -6.9 -7.1 11/27/2005 15:00:00 15.3 2 20.2 9.9 15 1.9 20.2 9.5 115 12 130 305 -7 0 -6.7 -7.1 11/27/2005 15:10:00 15.4 2.1 21.4 10.3 15.1 2 21 9.9 117 13 106 305 -6.9 0 -6.7 -7.1 11/27/2005 15:20:00 15.4 2.3 21 9.5 15 2.4 21.8 9.1 114 11 107 305 -6.8 0 -6.4 -6.9 11/27/2005 15:30:00 15 2.5 22.9 9.1 14.7 2.4 21 8.8 117 12 127 305 -6.7 0 -6.7 -6.9 11/27/2005 15:40:00 13.2 2.3 20.2 8.8 12.8 2.3 19.5 8.4 109 13 108 305 -6.6 0 -6.2 -6.9 11/27/2005 15:50:00 15.3 1.9 21 10.7 14.8 2 21 9.9 107 13 114 305 -6.5 0 -6.4 -6.7 11/27/2005 16:00:00 14.3 2.3 20.2 9.1 13.9 2.3 19.9 7.6 109 13 102 305 -6.4 0.1 -6 -6.7 11/27/2005 16:10:00 15.2 2.4 22.6 9.1 14.7 2.4 22.6 8.8 109 12 133 305 -6.4 0 -6.2 -6.7 11/27/2005 16:20:00 14.7 2.1 19.9 8.4 14.3 2 19.9 8.8 113 14 117 305 -6.3 0 -6.2 -6.4 11/27/2005 16:30:00 14 2.1 19.5 8.8 13.6 2.1 19.1 8 113 13 110 305 -6.3 0 -6 -6.4 11/27/2005 16:40:00 13.7 2.1 21.4 7.6 13.3 2 19.5 7.6 110 13 89 305 -6.2 0 -5.8 -6.2 11/27/2005 16:50:00 14 2.3 20.6 7.6 13.5 2.3 21.4 8 118 12 123 305 -6.1 0 -5.8 -6.2 11/27/2005 17:00:00 15.5 2.1 20.2 9.9 15 2 20.6 9.9 114 13 134 305 -6.1 0 -6 -6.2 11/27/2005 17:10:00 15.1 2 20.6 9.5 14.7 2.1 20.2 9.9 116 13 138 305 -6.1 0 -6 -6.2 11/27/2005 17:20:00 15.9 2.1 21.4 10.7 15.5 2 19.9 9.5 111 11 103 305 -6 0 -5.8 -6.2 11/27/2005 17:30:00 15.8 2.4 21 9.1 15.2 2.3 20.2 8.8 109 10 112 305 -6 0 -5.8 -6 11/27/2005 17:40:00 14.6 2.4 20.6 8.4 14.2 2.3 20.6 8.4 110 13 94 305 -5.8 0 -5.6 -6 11/27/2005 17:50:00 13.1 2.3 19.1 8 12.9 2.2 19.5 6.1 113 13 103 305 -5.7 0 -5.6 -5.8 11/27/2005 18:00:00 12 2.3 20.2 5.7 11.7 2.2 17.9 4.6 113 15 144 305 -5.6 0 -5.1 -5.8 11/27/2005 18:10:00 10.7 2.5 19.1 5.3 10.4 2.3 17.2 5.7 112 17 94 305 -5.5 0 -5.1 -5.8 11/27/2005 18:20:00 10.6 2 15.6 6.1 10.2 2 16.4 4.6 109 14 103 305 -5.3 0.1 -5.1 -5.6 11/27/2005 18:30:00 10 1.9 15.3 6.1 9.8 1.9 15.3 5.7 103 19 82 305 -5.3 0.1 -4.9 -5.6 11/27/2005 18:40:00 8.3 2.2 14.5 3 8.1 2.1 15.3 3.8 86 23 46 305 -5.5 0 -5.1 -5.6 11/27/2005 18:50:00 9.5 2.4 15.3 4.6 9.3 2.4 14.9 4.2 72 14 75 305 -5.6 0.1 -5.1 -5.8 11/27/2005 19:00:00 10.6 1.9 16.4 5.7 10.3 2 16.8 5.3 81 14 89 305 -6 0 -5.6 -6 11/27/2005 19:10:00 9.5 1.9 16.1 5.3 9.4 1.9 14.9 4.6 80 16 93 305 -6 0 -5.8 -6 11/27/2005 19:20:00 8.3 2.6 14.1 2.3 8 2.5 13.7 2.3 76 17 71 305 -5.9 0 -5.8 -6 11/27/2005 19:30:00 7.4 1.7 13.7 4.2 7.4 1.6 12.6 3.4 77 17 116 305 -5.7 0 -5.6 -5.8 11/27/2005 19:40:00 9.2 2.1 14.5 3.8 9.3 2.1 15.3 3.8 71 13 64 305 -5.7 0 -5.3 -5.8 11/27/2005 19:50:00 9.8 1.9 14.5 4.9 9.8 2 16.1 4.2 73 13 74 305 -5.8 0 -5.6 -6 11/27/2005 20:00:00 10.5 2.2 16.8 4.2 10.3 2.3 16.8 4.2 77 13 72 305 -5.7 0 -5.3 -5.8 11/27/2005 20:10:00 9.7 2.3 16.8 4.2 9.6 2.5 18.3 3.8 82 16 72 305 -5.6 0 -5.1 -5.8 11/27/2005 20:20:00 11.3 2.2 16.8 6.5 11 2.3 17.9 6.1 83 17 79 305 -5.5 0 -5.1 -5.8 11/27/2005 20:30:00 9.9 2.3 17.9 4.9 9.5 2.4 16.1 4.2 85 20 65 305 -5.6 0 -5.1 -5.8 11/27/2005 20:40:00 10.8 2.5 17.6 5.7 10.6 2.6 17.2 4.6 81 18 83 305 -5.5 0 -5.1 -5.8 11/27/2005 20:50:00 9.9 2.2 16.8 4.9 9.4 2.3 17.9 4.6 98 17 75 305 -5.5 0 -5.1 -5.8 11/27/2005 21:00:00 9.3 2.2 14.9 4.2 9 2.1 14.1 3.8 86 18 77 305 -5.7 0 -5.3 -5.8 11/27/2005 21:10:00 8.2 2 14.5 2.6 7.8 1.9 14.9 3.4 90 20 71 305 -5.5 0 -5.1 -5.8 11/27/2005 21:20:00 9.7 2.3 16.4 4.2 9.4 2.3 16.1 4.2 76 20 101 305 -5.7 0.1 -5.3 -6 11/27/2005 21:30:00 10.8 2.3 17.9 5.3 11 2.3 17.2 5.7 71 14 78 305 -5.8 0 -5.6 -6 11/27/2005 21:40:00 10.2 2.4 16.4 4.2 10 2.5 17.9 3.8 78 19 93 305 -5.7 0 -5.6 -6 11/27/2005 21:50:00 11.2 1.7 15.6 6.8 11.3 1.7 15.3 6.1 67 12 50 305 -5.6 0 -5.3 -5.8 11/27/2005 22:00:00 11.1 2.3 16.8 4.6 11.2 2.3 17.2 5.3 72 13 75 305 -5.5 0 -5.1 -5.8 11/27/2005 22:10:00 12.6 1.4 16.4 8.4 12.5 1.5 16.4 7.6 73 9 77 305 -5.9 0.1 -5.6 -6 11/27/2005 22:20:00 12.6 1.8 17.6 8 12.6 1.8 17.2 8.4 72 8 69 305 -6 0 -5.6 -6 11/27/2005 22:30:00 12.9 2.6 20.6 6.1 12.8 2.5 21.4 7.2 73 13 76 305 -6 0 -5.8 -6.2 11/27/2005 22:40:00 14.1 2.5 22.9 7.6 14 2.6 22.9 8 74 14 68 305 -6 0 -5.8 -6.2 11/27/2005 22:50:00 14.9 2.1 21 9.5 14.9 2.3 21.8 8.8 73 11 80 305 -6.2 0 -5.8 -6.2 11/27/2005 23:00:00 15.3 2.8 24 8 14.9 3.1 23.7 7.2 74 12 69 305 -6.3 0 -5.8 -6.4 11/27/2005 23:10:00 15 3.2 22.9 7.2 15 3.5 22.9 4.9 73 15 57 305 -6.3 0 -6 -6.4 11/27/2005 23:20:00 14.2 3.5 24.4 5.7 14.2 3.6 24.4 5.3 73 17 81 305 -6.3 0 -6 -6.4 11/27/2005 23:30:00 14.4 3.3 22.9 6.8 14.3 3.5 24 6.8 77 16 69 305 -6.3 0 -6.2 -6.4 11/27/2005 23:40:00 15.8 2.6 22.6 9.9 15.8 2.6 22.9 10.3 75 12 65 305 -6.3 0 -6.2 -6.4 11/27/2005 23:50:00 15.8 3.1 25.2 6.1 15.6 3.1 25.2 7.6 71 13 60 305 -6.3 0 -6 -6.4 11/28/2005 00:00:00 15.3 3.1 22.9 6.5 15.2 3.3 23.3 7.6 75 12 78 305 -6.3 0 -6 -6.4 11/28/2005 00:10:00 16 2.9 25.2 8.4 15.8 2.9 25.6 8.4 73 13 75 305 -6.2 0 -6.2 -6.4 11/28/2005 00:20:00 16 2.8 22.9 8 15.9 2.9 24 9.1 74 13 80 305 -6.3 0 -6.2 -6.4 11/28/2005 00:30:00 17.1 2.9 24.4 8.8 16.8 3.1 24.8 8.4 73 13 85 305 -6.3 0 -6.2 -6.4 11/28/2005 00:40:00 17.5 3.1 26.3 9.9 17.3 3.2 26 9.1 75 13 82 305 -6.4 0 -6.2 -6.7 11/28/2005 00:50:00 17.5 2.3 24.8 10.3 17.2 2.3 24 10.3 77 9 83 305 -6.4 0 -6.2 -6.7 11/28/2005 01:00:00 17.4 2.3 24 9.9 17.1 2.5 22.9 10.3 75 10 70 305 -6.6 0 -6.4 -6.9 11/28/2005 01:10:00 18.2 2.6 25.2 10.7 18 2.6 25.2 10.7 76 11 71 305 -6.7 0 -6.7 -6.9 11/28/2005 01:20:00 18.5 1.9 23.7 11.8 18.2 1.9 23.3 11.5 74 8 89 305 -6.9 0 -6.7 -7.1 11/28/2005 01:30:00 18.5 2.7 27.1 11.5 18.3 2.7 26 11.1 73 10 89 305 -6.9 0 -6.7 -7.1 11/28/2005 01:40:00 19.7 2.2 25.2 14.1 19.4 2.2 24.8 13.7 74 8 71 305 -6.9 0 -6.7 -7.1 11/28/2005 01:50:00 18.9 2.1 24.8 13.3 18.4 2.1 24 12.6 78 6 75 305 -6.8 0 -6.4 -6.9 11/28/2005 02:00:00 18.2 2.1 24.4 10.7 17.8 2.3 24.8 9.9 77 7 75 305 -6.7 0 -6.2 -6.9 11/28/2005 02:10:00 18 2.1 22.1 12.2 17.5 2.1 22.6 12.2 76 8 86 305 -6.5 0.1 -6.2 -6.7 11/28/2005 02:20:00 18.2 1.8 22.9 13.3 18 2 22.6 11.5 74 7 70 305 -6.4 0.1 -6 -6.7 11/28/2005 02:30:00 18.7 2.1 23.7 13 18.3 2.2 23.3 12.2 77 6 80 305 -6.4 0.1 -6 -6.7 11/28/2005 02:40:00 18.6 2.3 23.7 11.5 18.2 2.3 24.4 11.8 76 8 74 305 -6.4 0.1 -6 -6.7 11/28/2005 02:50:00 18 2.1 22.9 11.1 17.7 2.1 22.6 11.1 75 7 70 305 -6.4 0.1 -6 -6.7 11/28/2005 03:00:00 18.1 2.4 24.4 9.1 17.8 2.5 23.3 11.1 75 9 78 305 -6.3 0 -6 -6.4 11/28/2005 03:10:00 18.9 2.2 24.4 13 18.5 2.5 24.8 11.8 75 8 87 305 -6.4 0.1 -6 -6.4 11/28/2005 03:20:00 18.7 2.3 25.2 13.7 18.6 2.4 26.8 12.6 75 8 86 305 -6.3 0 -6 -6.4 11/28/2005 03:30:00 17.9 3.1 27.1 10.7 17.9 3.1 26.8 9.1 75 12 73 305 -6.2 0 -6 -6.4 11/28/2005 03:40:00 18.9 2.8 29.1 12.6 18.8 2.9 28.3 11.8 73 11 77 305 -6.3 0 -6 -6.4 11/28/2005 03:50:00 18.5 3.3 27.1 11.5 18.6 3.3 28.7 11.1 75 13 70 305 -6.3 0 -6 -6.4 11/28/2005 04:00:00 17 3.8 30.2 8 17 4.1 30.6 6.1 80 16 76 305 -6.3 0 -6 -6.4 11/28/2005 04:10:00 17.5 3.8 27.9 9.1 17.1 4 29.4 7.6 83 17 65 305 -6.2 0 -6.2 -6.4 11/28/2005 04:20:00 15.5 3.5 26 6.8 15.3 3.5 26 8 82 17 79 305 -6.2 0 -6 -6.4 11/28/2005 04:30:00 16.5 3.5 24.8 7.6 16.3 3.6 25.2 7.2 79 17 87 305 -6.1 0 -6 -6.2 11/28/2005 04:40:00 15.6 3.3 25.6 8 15.5 3.5 26.3 7.2 76 16 70 305 -6 0 -5.8 -6.2 11/28/2005 04:50:00 14.9 3.2 24 7.2 15 3.3 26.8 7.2 73 17 80 305 -5.8 0 -5.6 -6 11/28/2005 05:00:00 13.6 3.2 23.7 5.3 13.4 3.3 23.3 6.1 73 17 95 305 -5.7 0 -5.6 -6 11/28/2005 05:10:00 13.1 2.9 22.1 5.3 12.9 2.9 22.1 5.3 79 19 72 305 -5.6 0 -5.6 -5.8 11/28/2005 05:20:00 9.9 2.6 17.2 3.8 9.6 2.5 17.9 3.8 89 22 78 305 -5.5 0 -5.1 -5.8 11/28/2005 05:30:00 11.4 2.9 18.3 3.4 11 2.9 19.5 4.6 105 19 123 305 -5 0.2 -4.7 -5.6 11/28/2005 05:40:00 12.9 2.2 17.2 6.1 12.4 2.2 17.6 6.5 106 15 97 305 -4.6 0 -4.5 -4.7 11/28/2005 05:50:00 14.9 2.6 22.6 8.8 14.3 2.5 20.6 8 108 13 103 305 -4.5 0 -4.2 -4.7 11/28/2005 06:00:00 14.2 2.3 19.9 7.6 13.6 2.4 19.9 7.6 110 12 103 305 -4.2 0 -4 -4.5 11/28/2005 06:10:00 13 2.4 18.7 6.8 12.6 2.5 18.3 6.8 116 15 114 305 -4 0.1 -3.3 -4.2 11/28/2005 06:20:00 12.8 2.3 19.5 6.8 12.5 2.1 17.9 8.4 126 12 128 305 -3.5 0.1 -3.1 -3.8 11/28/2005 06:30:00 13 1.7 17.2 9.1 12.7 1.7 17.6 8.8 132 10 144 305 -2.8 0.1 -2.4 -3.3 11/28/2005 06:40:00 10.8 1.5 14.9 7.2 10.6 1.4 14.1 6.8 137 8 126 305 -2.4 0.2 -1.8 -2.7 11/28/2005 06:50:00 9.1 1 12.6 6.8 8.9 1 12.2 6.5 142 9 147 305 -1.8 0 -1.5 -2.2 11/28/2005 07:00:00 9.7 1.5 14.9 6.5 12.4 2.1 16.4 6.5 166 8 174 305 -0.2 0.8 0.6 -1.8 11/28/2005 07:10:00 10 1.3 13 5.7 12.3 1.3 16.1 9.1 177 7 182 305 1 4.2 39.3 0.3 11/28/2005 07:20:00 11.7 1.7 16.1 7.2 13.5 1.3 16.8 10.3 177 5 188 305 0.5 0 0.6 0.3 11/28/2005 07:30:00 13.6 1.3 17.2 9.5 13.9 1.3 17.2 9.1 185 5 183 305 0.4 0 0.6 0.3 11/28/2005 07:40:00 13.8 1.1 16.8 10.7 13.7 1.2 16.8 10.7 180 3 184 305 0.4 0 0.6 0.3 11/28/2005 07:50:00 13.2 0.9 16.1 10.7 13.4 0.8 15.6 11.1 187 6 193 305 0.4 0 0.6 0.3 11/28/2005 08:00:00 14.7 1.1 17.9 11.8 14.4 1.2 17.6 11.5 192 3 193 305 0.4 0 0.6 0.3 11/28/2005 08:10:00 15.3 0.9 17.9 13.3 14.8 1 17.2 11.8 192 3 194 305 0.4 0 0.6 0.3 11/28/2005 08:20:00 13.9 1 16.4 11.1 14 0.8 16.1 11.1 189 3 198 305 0.4 0 0.6 0.1 11/28/2005 08:30:00 12.6 1 15.3 9.5 13 0.9 15.3 9.9 188 4 189 305 0 0 0.3 -0.4 11/28/2005 08:40:00 13.3 1 16.1 10.3 13.5 1 16.1 10.7 188 3 187 305 -0.3 0 0.1 -0.4 11/28/2005 08:50:00 13.4 0.9 15.6 10.7 13.4 0.9 15.6 10.7 190 3 189 305 -0.3 0 0.3 -0.4 11/28/2005 09:00:00 12.8 0.8 15.3 9.9 12.6 0.9 14.9 10.3 190 4 197 305 -0.4 0 0.1 -0.6 11/28/2005 09:10:00 12.6 1 14.9 9.5 12.6 1 15.6 9.5 188 3 193 305 -0.4 0 0.1 -0.6 11/28/2005 09:20:00 12.3 0.9 15.3 9.9 12.4 0.9 14.9 10.3 188 3 198 305 -0.5 0.1 0.1 -0.6 11/28/2005 09:30:00 12.6 0.9 14.9 9.9 13 0.8 14.9 10.7 187 3 187 305 -0.4 0 -0.1 -0.6 11/28/2005 09:40:00 12.4 1.1 14.9 8.4 13.6 1.1 16.1 9.5 185 4 188 305 -0.2 0.1 0.3 -0.4 11/28/2005 09:50:00 12 1.3 14.9 6.8 13.8 1.1 16.1 9.9 183 4 180 305 0.2 0 0.6 0.1 11/28/2005 10:00:00 10.8 1.5 13.7 6.1 12.9 1.1 15.3 9.1 182 5 186 305 0.3 0 0.8 0.1 11/28/2005 10:10:00 10.1 1.7 13.7 6.1 12.4 1.1 14.5 9.5 181 5 183 305 0.2 0 0.8 0.1 11/28/2005 10:20:00 11.6 1.6 14.5 7.6 13.5 1.2 15.6 10.3 183 4 186 305 0.3 0.1 0.6 0.1 11/28/2005 10:30:00 11.7 1.6 15.3 6.8 13.6 1.1 15.6 10.3 182 4 186 305 0.5 0 0.8 0.6 11/28/2005 10:40:00 11.2 1.5 14.1 7.2 13.4 1 16.1 9.9 181 4 187 305 0.5 0 1 0.6 11/28/2005 10:50:00 9.2 1.7 14.1 5.7 12 1.1 14.5 9.1 178 6 188 305 0.6 0 1 0.6 11/28/2005 11:00:00 9.2 1.2 12.6 6.5 13.5 1 16.8 9.9 175 5 184 305 0.5 0 1 0.6 11/28/2005 11:10:00 9.9 1.7 14.5 6.8 13.4 1.1 15.6 9.9 177 5 191 305 0.7 0.1 1.3 0.6 11/28/2005 11:20:00 9.8 1.7 13.7 6.1 12 1.1 15.3 8.8 179 5 188 305 0.5 0 1 0.3 11/28/2005 11:30:00 9.5 1.6 13.3 5.7 11.9 1 14.5 8.4 179 5 188 305 0.5 0 1.3 0.3 11/28/2005 11:40:00 11 1.4 13.7 6.1 12.6 1 14.9 9.9 181 4 186 305 0.5 0 1 0.3 11/28/2005 11:50:00 11.2 1.3 13.7 6.1 12.5 1.1 15.3 8.8 183 4 179 305 0.4 0.1 1 0.1 11/28/2005 12:00:00 10.7 1 12.6 7.2 11.5 0.8 13.3 8 184 3 187 305 0 0 0.6 -0.4 11/28/2005 12:10:00 10.9 1 13.7 8 11.7 0.9 14.5 9.1 184 3 186 305 -0.2 0 0.6 -0.4 11/28/2005 12:20:00 10.1 1.1 12.2 6.5 11.2 0.8 13 8.8 183 3 183 305 -0.1 0 0.6 -0.4 11/28/2005 12:30:00 9.3 1.2 11.8 5.7 10.6 0.8 12.6 8.4 182 3 184 305 -0.1 0 0.6 -0.4 11/28/2005 12:40:00 8.3 1.5 11.8 3.8 10.2 0.9 12.2 8 181 5 184 305 -0.1 0 0.3 -0.4 11/28/2005 12:50:00 8.7 1.3 12.2 5.7 10.7 1 13.7 8.4 181 4 182 305 0.2 0 0.8 0.1 11/28/2005 13:00:00 9.3 1 12.2 6.1 10.7 0.9 12.6 7.2 182 4 185 305 0.1 0 0.3 0.1 11/28/2005 13:10:00 8.5 1.2 11.5 4.9 10.1 0.8 11.8 8 181 4 182 305 0 0 0.3 0.1 11/28/2005 13:20:00 8.2 1.2 10.7 4.6 9.8 0.8 11.5 7.2 181 4 179 305 0.1 0 0.6 0.1 11/28/2005 13:30:00 8.5 0.9 10.7 5.7 9.4 0.6 11.1 8 183 3 187 305 -0.1 0 0.6 -0.4 11/28/2005 13:40:00 7.2 1.2 9.9 4.6 9 0.8 10.7 6.5 179 5 184 305 0.1 0 0.6 0.1 11/28/2005 13:50:00 7.6 1.2 10.3 4.6 9.2 0.7 11.1 7.2 178 4 181 305 0.3 0 0.8 0.1 11/28/2005 14:00:00 8.4 1.2 10.7 4.9 9.8 0.7 11.1 7.6 178 5 183 305 0.2 0 0.6 0.1 11/28/2005 14:10:00 9.3 1 11.5 6.1 10.4 0.7 11.8 8.4 179 4 179 305 0 0 0.3 0.1 11/28/2005 14:20:00 9.4 0.8 11.1 6.5 10 0.6 11.5 8 181 3 177 305 -0.1 0 0.6 -0.4 11/28/2005 14:30:00 9 0.6 10.7 7.6 9 0.6 10.3 7.2 183 3 183 305 -0.4 0.1 0.1 -0.6 11/28/2005 14:40:00 8.5 0.6 9.9 6.5 8.7 0.5 10.3 6.5 182 3 188 305 -0.6 0 -0.1 -0.6 11/28/2005 14:50:00 8.4 0.8 9.9 6.1 9.3 0.6 10.7 7.2 180 3 180 305 -0.4 0.1 0.1 -0.6 11/28/2005 15:00:00 8.6 0.8 11.1 6.1 9.3 0.7 11.1 7.2 180 3 182 305 -0.4 0.1 0.1 -0.6 11/28/2005 15:10:00 8.5 1.2 10.7 4.9 9.8 0.8 11.8 6.8 179 4 186 305 -0.3 0 0.1 -0.4 11/28/2005 15:20:00 8.8 1.1 11.1 4.6 10 0.8 11.8 7.6 179 4 183 305 -0.2 0 0.3 -0.4 11/28/2005 15:30:00 9.2 0.9 11.1 6.8 10.3 0.6 11.8 8.4 179 3 183 305 -0.1 0 0.3 -0.4 11/28/2005 15:40:00 9.5 1 11.5 6.8 10.4 0.7 11.8 8.4 180 3 181 305 -0.1 0 0.3 -0.4 11/28/2005 15:50:00 9.2 1 11.5 5.7 10.4 0.7 11.8 8.4 179 3 184 305 -0.3 0 0.3 -0.4 11/28/2005 16:00:00 9.9 0.8 11.5 6.8 10.8 0.6 11.8 9.1 180 3 180 305 -0.3 0 0.3 -0.6 11/28/2005 16:10:00 9.5 1 11.5 5.7 10.6 0.7 11.8 8 180 3 186 305 -0.4 0.1 0.1 -0.6 11/28/2005 16:20:00 9.2 1 11.1 5.7 10.3 0.7 11.8 8.4 180 3 182 305 -0.5 0 0.1 -0.6 11/28/2005 16:30:00 9 1 10.7 5.7 10.1 0.8 11.5 7.6 179 3 183 305 -0.5 0 0.1 -0.6 11/28/2005 16:40:00 9.1 1 11.1 6.1 10.1 0.7 11.5 7.6 179 3 183 305 -0.5 0 0.1 -0.6 11/28/2005 16:50:00 8.9 1 10.7 4.9 9.8 0.7 11.5 7.6 179 3 181 305 -0.5 0 0.1 -0.6 11/28/2005 17:00:00 8.5 1 11.1 4.9 9.4 0.7 11.5 6.8 180 4 184 305 -0.4 0.1 0.1 -0.6 11/28/2005 17:10:00 8.1 1.3 10.7 4.6 9.3 0.8 11.8 7.6 179 5 184 305 -0.4 0.1 0.1 -0.6 11/28/2005 17:20:00 8 1.3 10.7 3.8 9.2 0.8 11.1 7.2 178 5 181 305 -0.4 0.1 0.1 -0.6 11/28/2005 17:30:00 7 1.3 9.5 3.4 8.5 0.8 10.3 5.7 177 6 182 305 -0.3 0 0.1 -0.6 11/28/2005 17:40:00 8.5 1.2 11.5 4.9 9.5 0.8 11.5 7.2 179 4 183 305 -0.3 0 0.1 -0.4 11/28/2005 17:50:00 8.2 1.5 11.1 4.6 9.9 0.9 11.8 7.2 177 5 186 305 0 0 0.6 -0.4 11/28/2005 18:00:00 7.9 1.5 11.5 4.2 9.3 1 11.5 7.2 177 5 175 305 -0.1 0 0.1 -0.4 11/28/2005 18:10:00 7.7 1.5 11.5 4.2 9.1 0.8 11.5 7.2 178 5 188 305 -0.2 0 0.1 -0.4 11/28/2005 18:20:00 8.2 1.6 11.5 4.2 9.5 0.9 11.5 7.2 178 5 184 305 -0.2 0 0.1 -0.4 11/28/2005 18:30:00 8.6 1.5 11.8 4.6 9.9 1 12.2 7.2 178 5 186 305 -0.1 0 0.1 -0.4 11/28/2005 18:40:00 8.1 1.5 11.1 4.6 9.6 0.8 11.1 7.2 177 5 182 305 0 0 0.3 -0.1 11/28/2005 18:50:00 7.8 1.5 11.1 4.6 9.5 0.9 11.8 6.8 176 5 184 305 0 0 0.6 0.1 11/28/2005 19:00:00 8.4 1.1 10.7 4.9 9.9 0.7 11.5 8 178 4 180 305 0.2 0 0.6 0.1 11/28/2005 19:10:00 7.6 1.3 10.7 4.2 9.4 0.8 11.8 7.2 176 6 181 305 0.1 0.1 0.6 0.1 11/28/2005 19:20:00 7.4 1.3 10.7 4.6 9.2 1 11.5 6.5 176 6 183 305 0.1 0 0.3 -0.1 11/28/2005 19:30:00 6.7 1.1 9.9 4.2 7.4 0.9 9.9 5.7 159 11 186 305 -1 0.6 0.1 -1.8 11/28/2005 19:40:00 7.4 0.6 9.1 5.3 7.3 0.5 8.8 5.7 148 7 149 305 -1.5 0.1 -1.1 -1.8 11/28/2005 19:50:00 6.7 0.7 8.4 3.8 7 0.5 8.4 5.7 151 8 145 305 -1.5 0 -1.1 -1.8 11/28/2005 20:00:00 5.8 1.2 9.5 3.4 7.2 1 9.9 5.3 167 9 184 305 -1.2 0.3 -0.6 -1.8 11/28/2005 20:10:00 5.9 1.2 9.5 3.4 7.7 1 10.7 5.7 168 8 181 305 -0.7 0.2 -0.4 -1.3 11/28/2005 20:20:00 5.5 1 8.4 3 7.1 0.6 9.9 5.7 164 8 185 305 -1 0 -0.8 -1.1 11/28/2005 20:30:00 5.7 1.1 9.1 3.4 7.8 1 11.1 5.7 168 8 182 305 -0.7 0.5 0.3 -1.1 11/28/2005 20:40:00 6.1 1 8.4 3.8 7 0.7 9.5 5.3 160 11 166 305 -0.4 0.5 0.3 -1.1 11/28/2005 20:50:00 5.7 1 8.8 3 6.5 0.8 8 4.6 160 9 159 305 -1.3 0.1 -1.1 -1.8 11/28/2005 21:00:00 7.6 1 9.9 4.9 7.6 1 9.9 5.3 149 6 152 305 -1.6 0 -1.3 -1.8 11/28/2005 21:10:00 7.9 0.8 10.3 4.6 7.9 0.6 9.1 5.3 146 6 155 305 -1.6 0 -1.3 -1.8 11/28/2005 21:20:00 8.6 0.7 11.1 6.1 8.6 0.7 10.3 6.8 144 5 154 305 -1.6 0 -1.3 -1.8 11/28/2005 21:30:00 8.4 1 10.7 5.3 8.4 0.6 10.3 6.8 153 6 150 305 -1.8 0.1 -1.5 -2 11/28/2005 21:40:00 7.8 1 10.3 4.6 7.8 0.7 9.5 5.7 153 7 149 305 -1.8 0 -1.3 -2 11/28/2005 21:50:00 6.8 1.4 9.9 3.8 7.9 0.7 9.5 6.5 159 7 150 305 -1.6 0 -1.5 -1.8 11/28/2005 22:00:00 7 1 9.5 4.6 8 0.5 9.5 6.5 158 5 160 305 -1.4 0.1 -1.1 -1.8 11/28/2005 22:10:00 6.5 1.1 8.8 3.4 7.2 0.6 9.1 5.3 157 8 160 305 -1.3 0 -0.8 -1.5 11/28/2005 22:20:00 7.6 1 9.9 4.9 7.7 0.7 9.5 6.1 155 6 150 305 -1.5 0 -1.1 -1.8 11/28/2005 22:30:00 8 0.8 10.3 5.7 7.7 0.7 9.5 6.1 151 6 160 305 -1.5 0 -1.1 -1.8 11/28/2005 22:40:00 7 0.7 8.8 4.2 6.9 0.5 8.4 5.3 147 6 162 305 -1.5 0.1 -1.1 -1.8 11/28/2005 22:50:00 8 0.7 10.3 4.9 7.7 0.6 9.9 6.1 142 5 154 305 -1.4 0 -0.8 -1.8 11/28/2005 23:00:00 7.3 0.6 9.1 6.1 7.2 0.5 8.4 5.7 143 5 138 305 -1.2 0 -0.6 -1.3 11/28/2005 23:10:00 6.9 0.6 8.4 5.3 6.7 0.6 8 5.3 143 4 150 305 -1.2 0 -0.8 -1.3 11/28/2005 23:20:00 7 0.5 8.4 4.9 6.8 0.5 8 4.9 144 4 154 305 -1.3 0 -0.8 -1.3 11/28/2005 23:30:00 7.2 0.6 8.8 5.3 7 0.6 8.4 5.3 145 5 150 305 -1.3 0 -1.1 -1.5 11/28/2005 23:40:00 7.5 0.8 9.5 4.2 7.7 0.5 8.8 6.5 153 6 153 305 -1.4 0 -1.1 -1.5 11/28/2005 23:50:00 6.8 1.1 9.1 4.2 7.7 0.5 9.1 6.5 158 5 155 305 -1.2 0 -0.8 -1.3 11/29/2005 00:00:00 6 1.2 9.5 3.8 8.2 1 10.7 6.5 167 8 183 305 -1 0.1 -0.6 -1.1 11/29/2005 00:10:00 7.6 1.2 10.3 4.6 9.1 0.7 10.7 6.8 177 5 182 305 -0.1 0.1 0.3 -0.6 11/29/2005 00:20:00 8.6 0.8 10.3 4.9 9.5 0.6 11.1 8 180 3 182 305 -0.1 0 0.1 -0.4 11/29/2005 00:30:00 7.7 1.2 10.3 4.2 8.8 0.8 10.7 6.5 179 4 181 305 -0.2 0 0.1 -0.4 11/29/2005 00:40:00 7.1 1.2 9.5 3.8 8 0.7 9.5 5.7 179 5 188 305 -0.5 0 0.1 -0.6 11/29/2005 00:50:00 7.1 1 9.1 4.2 8 0.7 9.5 6.1 179 4 183 305 -0.4 0.1 0.1 -0.6 11/29/2005 01:00:00 6.1 1 8 3.4 6.9 0.7 8.8 5.7 179 5 178 305 -0.5 0.1 0.1 -0.6 11/29/2005 01:10:00 7.8 0.8 9.1 4.6 8.2 0.5 9.1 6.5 182 3 188 305 -0.5 0 0.1 -0.6 11/29/2005 01:20:00 7.3 0.9 9.1 4.9 8 0.7 9.5 6.5 180 4 186 305 -0.2 0 0.3 -0.4 11/29/2005 01:30:00 7.8 0.8 9.5 4.2 8.3 0.6 9.9 6.5 181 3 181 305 -0.1 0 0.3 -0.4 11/29/2005 01:40:00 7.3 1.1 9.5 3.8 8.5 0.7 10.3 6.1 178 4 181 305 0.1 0.1 0.6 -0.1 11/29/2005 01:50:00 6.5 1.3 9.1 3.4 8 0.8 9.9 6.1 176 6 183 305 0.3 0 0.6 0.1 11/29/2005 02:00:00 7.4 1.2 9.9 4.2 8.5 0.7 10.7 5.7 178 5 188 305 0.3 0 1 0.1 11/29/2005 02:10:00 6.6 1.1 9.1 3.8 7.6 0.7 9.5 5.7 179 5 188 305 0.2 0 0.6 0.1 11/29/2005 02:20:00 6.8 0.9 8.4 3.8 7.7 0.6 9.1 6.1 179 4 188 305 0.1 0.1 0.6 0.1 11/29/2005 02:30:00 4.7 1.2 7.6 2.6 5.6 1 8 3.4 168 10 183 305 -0.4 0.4 0.3 -1.1 11/29/2005 02:40:00 5.6 0.9 8 3 5.7 0.7 7.2 3.8 154 6 141 305 -1 0.1 -0.4 -1.1 11/29/2005 02:50:00 5.9 0.6 8 3.8 5.8 0.5 7.2 4.6 150 6 163 305 -1.1 0 -0.6 -1.3 11/29/2005 03:00:00 5.9 0.7 8 3.8 6.1 0.5 8 4.9 151 8 163 305 -1.3 0 -1.1 -1.3 11/29/2005 03:10:00 5.1 1.1 8 2.6 6.2 0.8 8.4 4.2 175 8 183 305 -0.7 0.4 0.1 -1.3 11/29/2005 03:20:00 5.1 1.2 7.6 2.6 6.3 0.9 8.4 3.8 176 6 188 305 -0.1 0 0.1 -0.4 11/29/2005 03:30:00 5.4 0.9 7.2 3 6.7 0.5 7.6 5.3 177 4 183 305 -0.3 0 0.1 -0.4 11/29/2005 03:40:00 5.3 1.2 7.6 2.6 6.5 0.7 8 4.6 176 6 183 305 -0.4 0.1 0.3 -0.6 11/29/2005 03:50:00 5 0.9 6.8 2.6 5.7 0.6 7.2 4.2 178 5 181 305 -0.5 0 -0.1 -0.6 11/29/2005 04:00:00 4 0.8 5.7 2.3 4.8 0.5 6.1 3.4 179 6 181 305 -0.6 0 -0.1 -0.6 11/29/2005 04:10:00 3.7 0.7 4.9 1.9 4.4 0.4 5.3 3.4 178 6 192 305 -0.5 0 -0.1 -0.6 11/29/2005 04:20:00 3.6 0.7 5.3 1.5 4.3 0.4 5.3 3 164 13 140 305 -0.6 0 0.1 -0.8 11/29/2005 04:30:00 4 0.5 5.3 2.3 4.1 0.4 4.9 3 149 5 150 305 -0.8 0 -0.4 -1.1 11/29/2005 04:40:00 2.8 0.7 4.9 1.1 3.9 0.5 4.9 2.3 163 7 147 305 -0.9 0 -0.4 -1.1 11/29/2005 04:50:00 2.4 0.6 3.8 1.1 2.9 0.5 4.2 1.5 161 8 160 305 -0.8 0 -0.4 -1.1 11/29/2005 05:00:00 2.2 0.6 3.8 1.1 3.2 0.4 4.2 2.3 168 9 150 305 -0.8 0 -0.4 -1.1 11/29/2005 05:10:00 2 0.5 3 0.7 2.2 0.5 3.4 1.1 183 8 184 305 -0.5 0 -0.1 -0.6 11/29/2005 05:20:00 2.4 0.4 3.4 1.5 2.3 0.4 3 1.5 196 5 196 305 -0.4 0 0.1 -0.6 11/29/2005 05:30:00 2.8 0.3 3.4 1.9 2.8 0.3 3.4 1.9 196 0 196 305 -0.4 0 0.1 -0.6 11/29/2005 05:40:00 2 0.6 3.4 0.7 2.4 0.4 3.4 1.1 195 0 196 305 -0.6 0 -0.4 -0.6 11/29/2005 05:50:00 2 0.5 3 0.7 2.4 0.4 3 1.5 195 0 195 305 -0.8 0 -0.4 -1.1 11/29/2005 06:00:00 3.1 0.5 4.2 1.9 3 0.5 4.2 1.9 195 0 194 305 -0.7 0 -0.4 -0.8 11/29/2005 06:10:00 3.9 0.4 5.3 3 3.8 0.5 4.9 2.6 195 0 194 305 -0.7 0 -0.4 -0.8 11/29/2005 06:20:00 3.7 0.6 4.9 2.3 3.7 0.6 4.9 2.3 195 0 195 305 -0.8 0 -0.4 -1.1 11/29/2005 06:30:00 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 195 0 195 305 -0.9 0 -0.4 -1.1 11/29/2005 06:40:00 2.3 0.4 3.4 1.1 2.4 0.4 3.4 1.5 195 0 195 305 -1.1 0 -0.6 -1.1 11/29/2005 06:50:00 3 0.4 3.8 2.3 2.6 0.3 3.4 1.9 195 0 195 305 -1.1 0 -0.6 -1.3 11/29/2005 07:00:00 3.1 0.3 3.8 2.3 2.5 0.4 3.4 1.5 196 0 196 305 -1.2 0 -0.6 -1.3 11/29/2005 07:10:00 2.6 0.3 3 1.9 2.1 0.3 2.6 1.5 196 0 196 305 -1.4 0 -0.8 -1.5 11/29/2005 07:20:00 2.2 0.2 2.6 1.5 2.1 0.4 3 1.1 196 0 196 305 -1.5 0 -1.3 -1.8 11/29/2005 07:30:00 2.5 0.3 3 1.9 2.5 0.3 3.4 1.9 196 0 196 305 -1.4 0 -0.8 -1.5 11/29/2005 07:40:00 2.9 0.3 3.8 2.3 2.9 0.3 3.8 2.3 196 0 196 305 -1.3 0 -1.1 -1.3 11/29/2005 07:50:00 3 0.4 3.8 1.9 3 0.3 4.2 2.3 196 0 196 305 -1.4 0 -1.1 -1.5 11/29/2005 08:00:00 3.1 0.3 3.8 2.3 3.1 0.3 4.2 1.9 196 0 196 305 -1.4 0 -1.1 -1.5 11/29/2005 08:10:00 3.2 0.5 4.6 1.9 3.1 0.5 4.6 1.9 196 0 196 305 -1.4 0 -1.3 -1.3 11/29/2005 08:20:00 3.1 0.4 4.2 1.9 3.1 0.4 4.2 2.3 196 0 196 305 -1.3 0 -1.1 -1.5 11/29/2005 08:30:00 3.2 0.4 4.2 2.3 3.1 0.4 4.2 1.9 196 0 196 305 -1.2 0 -1.1 -1.3 11/29/2005 08:40:00 2.8 0.3 3.4 2.3 2.8 0.3 3.4 1.9 196 0 196 305 -1.2 0 -1.1 -1.3 11/29/2005 08:50:00 2.7 0.4 3.8 1.9 2.7 0.3 3.4 1.9 196 0 196 305 -1.2 0 -1.1 -1.3 11/29/2005 09:00:00 3.2 0.4 4.2 2.3 2.9 0.4 4.2 2.3 196 0 196 305 -1.2 0 -1.1 -1.3 11/29/2005 09:10:00 3.4 0.4 4.6 2.6 2.9 0.3 3.8 1.9 197 0 196 305 -1.2 0 -1.1 -1.3 11/29/2005 09:20:00 4.3 0.5 5.7 2.6 3.7 0.6 4.9 2.3 218 17 227 305 -1.1 0 -0.8 -1.3 11/29/2005 09:30:00 4.9 0.7 6.5 3.4 4.1 0.6 5.7 2.6 238 7 239 305 -1 0 -0.6 -1.1 11/29/2005 09:40:00 4.9 0.7 6.1 3 4.1 0.7 5.7 2.3 248 6 255 305 -1 0.1 -0.6 -1.1 11/29/2005 09:50:00 4.8 0.5 5.7 3.4 3.9 0.6 5.3 2.6 254 6 256 305 -1 0 -0.8 -1.1 11/29/2005 10:00:00 4.4 0.4 5.7 3 3.6 0.5 4.6 2.3 252 7 258 305 -1.1 0 -0.6 -1.3 11/29/2005 10:10:00 4.2 0.4 4.9 3 3.5 0.4 4.6 2.6 231 6 236 305 -1.2 0 -0.8 -1.3 11/29/2005 10:20:00 3.7 0.3 4.2 2.6 3.2 0.4 4.2 2.3 233 5 234 305 -1.3 0 -0.8 -1.5 11/29/2005 10:30:00 3.6 0.4 4.6 2.3 3 0.3 3.8 2.3 228 6 234 305 -1.4 0 -1.3 -1.5 11/29/2005 10:40:00 2.8 0.3 3.4 2.3 2.4 0.3 3.4 1.5 222 9 220 305 -1.5 0 -1.1 -1.8 11/29/2005 10:50:00 3.4 0.5 4.6 2.3 3.4 0.5 4.2 2.3 205 6 208 305 -1.5 0 -1.1 -1.8 11/29/2005 11:00:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 203 7 210 305 -1.5 0.1 -1.1 -1.8 11/29/2005 11:10:00 2.9 0.4 3.8 1.9 3 0.5 3.8 1.9 197 8 213 305 -1.6 0 -1.5 -1.8 11/29/2005 11:20:00 2.8 0.5 3.8 1.5 2.7 0.5 3.8 1.5 196 9 192 305 -1.7 0 -1.8 -1.8 11/29/2005 11:30:00 2.3 0.5 3.4 1.1 2.2 0.4 3 0.7 211 16 208 305 -1.7 0 -1.3 -1.8 11/29/2005 11:40:00 1.8 0.6 3 0.4 1.5 0.5 2.6 0.4 223 13 238 305 -1.8 0 -1.8 -2 11/29/2005 11:50:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 219 16 251 305 -1.8 0 -1.8 -2 11/29/2005 12:00:00 2.2 0.4 3 1.1 2.2 0.4 3 1.5 213 8 214 305 -1.7 0 -1.5 -1.8 11/29/2005 12:10:00 2.9 0.9 5.3 1.5 3 1 5.7 1.5 202 10 188 305 -1.8 0.1 -1.3 -2.4 11/29/2005 12:20:00 2.7 0.5 3.8 1.1 2.7 0.6 3.8 1.1 209 13 194 305 -2 0.2 -1.8 -2.4 11/29/2005 12:30:00 2.8 0.6 3.8 1.1 2.7 0.7 3.8 1.1 208 12 206 305 -1.7 0 -1.1 -1.8 11/29/2005 12:40:00 2.2 0.7 4.2 0.4 2.2 0.7 3.8 0.4 208 11 203 305 -1.8 0 -1.8 -2 11/29/2005 12:50:00 1.6 0.5 3 0.4 1.4 0.4 2.6 0.7 221 22 267 305 -1.6 0 -1.1 -1.8 11/29/2005 13:00:00 1.1 0.5 2.3 0.4 1.2 0.5 2.6 0.4 215 13 217 305 -1.6 0 -1.1 -1.8 11/29/2005 13:10:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 203 23 205 305 -1.5 0 -1.3 -1.8 11/29/2005 13:20:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 234 23 261 305 -1.4 0 -0.8 -1.3 11/29/2005 13:30:00 2.7 1.7 5.7 0.4 2.9 1.7 5.7 0.4 208 23 184 305 -1.6 0.4 -0.8 -2.2 11/29/2005 13:40:00 2.3 0.5 3.4 1.1 2.5 0.5 3.4 1.5 210 13 214 305 -2.2 0 -2 -2.4 11/29/2005 13:50:00 2.2 0.6 3.4 0.7 2.2 0.6 3.4 0.7 209 17 190 305 -2 0.1 -1.5 -2.2 11/29/2005 14:00:00 1.4 0.6 3 0.4 1.2 0.6 3 0.4 245 24 254 305 -1.8 0 -1.3 -2 11/29/2005 14:10:00 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 222 14 252 305 -1.8 0 -1.8 -2 11/29/2005 14:20:00 0.9 0.5 1.9 0.4 0.6 0.3 1.5 0.4 252 19 268 305 -1.8 0 -1.8 -1.8 11/29/2005 14:30:00 1.8 0.5 3 0.4 1.4 0.5 2.6 0.4 251 15 281 305 -1.6 0 -1.1 -1.8 11/29/2005 14:40:00 2.1 0.5 3 0.7 2 0.5 2.6 0.4 292 23 305 305 -1.7 0 -1.3 -2 11/29/2005 14:50:00 1.9 0.4 2.6 0.7 1.8 0.4 2.6 0.7 296 18 290 305 -1.8 0 -1.5 -2 11/29/2005 15:00:00 1 0.5 2.3 0.4 0.9 0.6 2.3 0.4 267 30 301 305 -1.8 0 -1.3 -2 11/29/2005 15:10:00 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 233 21 218 305 -1.8 0 -1.8 -2 11/29/2005 15:20:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 258 21 297 305 -1.8 0 -1.8 -2 11/29/2005 15:30:00 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 300 9 297 305 -1.8 0 -1.8 -2 11/29/2005 15:40:00 1.2 0.5 2.3 0.4 1.4 0.6 2.6 0.4 319 7 327 305 -1.9 0 -1.8 -2 11/29/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 17 305 305 -2 0 -1.8 -2 11/29/2005 16:00:00 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 312 26 273 305 -1.9 0 -1.5 -2 11/29/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 285 0 305 305 -1.9 0 -1.8 -2 11/29/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 285 0 305 305 -1.9 0 -1.3 -2 11/29/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 296 22 305 305 -1.9 0 -1.5 -2 11/29/2005 16:40:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 12 19 24 305 -1.9 0 -1.8 -2 11/29/2005 16:50:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 34 16 24 305 -1.8 0 -1.8 -2 11/29/2005 17:00:00 0.7 0.4 1.5 0.4 0.8 0.4 1.5 0.4 22 8 14 305 -1.8 0 -1.3 -2 11/29/2005 17:10:00 1.5 0.3 2.3 0.7 1.6 0.3 2.3 0.7 13 8 18 305 -1.8 0 -1.3 -2 11/29/2005 17:20:00 2.2 0.5 4.9 1.5 2.2 0.5 5.7 1.5 349 12 27 305 -1.7 0 -1.1 -1.8 11/29/2005 17:30:00 7.5 1 9.1 4.2 7.3 1 9.1 3.8 28 6 32 305 -1.8 0 -1.3 -2 11/29/2005 17:40:00 7.6 0.7 9.1 6.1 7.5 0.7 9.1 5.7 33 4 33 305 -2 0.1 -1.8 -2.2 11/29/2005 17:50:00 7.4 0.6 8.8 5.7 7.3 0.6 9.1 5.3 32 5 24 305 -2 0.1 -1.8 -2.2 11/29/2005 18:00:00 7.7 0.8 9.5 5.7 7.5 0.8 9.1 5.3 28 5 25 305 -2.1 0 -2 -2.2 11/29/2005 18:10:00 8.5 0.6 9.9 6.8 8.2 0.7 9.9 6.5 30 5 29 305 -2.2 0 -1.8 -2.4 11/29/2005 18:20:00 8.2 1 10.3 6.1 8 1 9.9 5.7 33 5 35 305 -2.2 0 -1.8 -2.4 11/29/2005 18:30:00 7.9 0.7 9.5 6.1 7.8 0.7 9.5 5.7 32 5 37 305 -2.2 0 -1.8 -2.4 11/29/2005 18:40:00 7.5 0.9 9.5 5.3 7.5 0.9 9.9 5.7 32 5 34 305 -2.3 0 -1.8 -2.4 11/29/2005 18:50:00 9 0.8 10.7 6.8 8.7 0.9 10.7 6.1 33 5 30 305 -2.4 0 -1.8 -2.7 11/29/2005 19:00:00 9.5 0.8 11.1 7.6 9.2 0.8 10.7 6.5 32 4 32 305 -2.6 0.1 -2 -2.7 11/29/2005 19:10:00 9.8 0.8 11.5 7.2 9.6 0.8 11.1 6.8 33 5 32 305 -2.7 0 -2.2 -2.9 11/29/2005 19:20:00 9.8 0.9 11.5 7.6 9.6 0.8 11.8 8 29 5 32 305 -2.8 0 -2.4 -3.1 11/29/2005 19:30:00 10.4 0.9 12.6 8.4 10.3 0.9 12.6 8 28 4 30 305 -3.1 0.1 -2.7 -3.3 11/29/2005 19:40:00 10.5 1 12.6 8 10.2 0.9 12.6 8 29 4 32 305 -3.2 0 -2.7 -3.3 11/29/2005 19:50:00 10.7 0.9 12.6 8 10.4 0.9 12.6 8 30 5 25 305 -3.3 0 -2.7 -3.6 11/29/2005 20:00:00 10.8 1 12.6 8 10.5 1 12.6 8 31 4 32 305 -3.5 0 -3.3 -3.8 11/29/2005 20:10:00 10.6 0.8 12.2 8.4 10.4 0.9 12.2 8 30 4 32 305 -3.7 0 -3.1 -3.8 11/29/2005 20:20:00 10.5 1.1 13 7.6 10.2 1 12.6 7.6 30 5 30 305 -3.8 0 -3.3 -4 11/29/2005 20:30:00 10.5 1 13 8 10.1 1 12.6 7.2 30 5 30 305 -3.9 0 -3.3 -4 11/29/2005 20:40:00 10.9 0.8 13 8.8 10.5 0.8 12.2 8.4 31 5 29 305 -4 0 -3.8 -4 11/29/2005 20:50:00 11.1 0.8 13 9.1 10.9 0.9 13 8 35 4 33 305 -4 0 -3.3 -4.2 11/29/2005 21:00:00 10.8 1 12.6 8 10.6 1 13 7.6 31 4 32 305 -4 0 -3.8 -4.2 11/29/2005 21:10:00 10.9 1 13.3 8.8 10.7 1 13.3 8.4 33 5 34 305 -4.1 0 -4 -4.2 11/29/2005 21:20:00 10.5 0.9 12.6 8.4 10.2 1 12.6 8 31 6 32 305 -4.2 0 -4 -4.2 11/29/2005 21:30:00 10.4 0.7 12.2 8.4 10.3 0.8 12.2 8.4 31 5 28 305 -4.2 0 -3.8 -4.5 11/29/2005 21:40:00 10 1 11.8 7.6 9.9 1 11.8 7.2 29 5 24 305 -4.3 0 -4 -4.5 11/29/2005 21:50:00 10.7 1.1 12.6 7.2 10.7 1.1 13 7.6 33 5 35 305 -4.4 0 -4 -4.7 11/29/2005 22:00:00 10.9 0.9 12.6 8 10.9 1 12.6 7.6 38 5 36 305 -4.4 0 -3.8 -4.5 11/29/2005 22:10:00 10.7 0.9 12.6 8.4 10.8 0.8 12.2 8.4 38 4 42 305 -4.3 0 -3.8 -4.5 11/29/2005 22:20:00 11.1 1 13.3 8 11 1.1 13.3 7.6 35 6 40 305 -4.3 0 -3.8 -4.5 11/29/2005 22:30:00 10.9 0.9 12.6 8.4 10.9 1 12.6 8 36 5 39 305 -4.3 0 -3.8 -4.5 11/29/2005 22:40:00 11 0.7 12.6 8.8 11 0.8 12.6 8.4 37 4 33 305 -4.4 0 -3.8 -4.5 11/29/2005 22:50:00 10.4 0.8 11.8 8 10.4 0.9 12.2 8 38 5 41 305 -4.4 0 -4 -4.5 11/29/2005 23:00:00 10.2 0.8 11.8 8.4 10.1 0.9 12.2 8 34 5 38 305 -4.4 0 -4 -4.5 11/29/2005 23:10:00 10.1 0.6 11.5 8.4 10.1 0.7 11.5 8 32 4 37 305 -4.4 0 -4 -4.7 11/29/2005 23:20:00 9.8 0.8 11.5 7.6 9.8 0.8 11.8 7.2 34 5 36 305 -4.4 0 -4.5 -4.7 11/29/2005 23:30:00 10.2 0.6 11.1 8 10.2 0.6 11.5 7.6 29 3 30 305 -4.5 0 -4.5 -4.7 11/29/2005 23:40:00 10.2 0.5 11.5 8.4 10.1 0.6 11.5 8 27 4 24 305 -4.6 0 -4.5 -4.7 11/29/2005 23:50:00 10.3 0.5 11.5 8.4 10.4 0.6 11.5 8.4 29 4 32 305 -4.6 0 -4.5 -4.7 11/30/2005 00:00:00 10.4 0.6 11.8 8.4 10.2 0.8 11.8 7.6 30 5 26 305 -4.7 0 -4.5 -4.9 11/30/2005 00:10:00 10.1 0.5 11.1 8 9.9 0.6 11.5 7.6 29 4 27 305 -4.8 0 -4.7 -4.9 11/30/2005 00:20:00 10.6 0.6 11.8 8.4 10.6 0.7 11.8 8.4 32 3 32 305 -4.9 0 -4.7 -5.1 11/30/2005 00:30:00 10.7 0.6 11.8 7.6 10.4 0.8 12.2 8 28 5 25 305 -5 0 -4.7 -5.1 11/30/2005 00:40:00 10.7 0.6 11.8 8.8 10.6 0.7 11.8 8.8 30 4 23 305 -5.2 0.1 -5.1 -5.6 11/30/2005 00:50:00 10.6 0.7 11.8 8.8 10.5 0.8 12.2 8.8 34 5 35 305 -5.2 0 -5.1 -5.3 11/30/2005 01:00:00 10.9 0.7 12.2 8.8 10.8 0.9 13 8.8 33 4 38 305 -5.3 0 -5.1 -5.6 11/30/2005 01:10:00 10.9 0.6 12.6 9.1 10.8 0.7 12.2 8.4 37 4 37 305 -5.5 0 -5.3 -5.6 11/30/2005 01:20:00 10.7 0.7 12.6 8.4 10.5 0.8 12.2 7.6 33 5 32 305 -5.5 0 -5.3 -5.8 11/30/2005 01:30:00 10.4 0.7 11.8 8.8 10.1 0.8 12.2 8 34 4 38 305 -5.6 0 -5.6 -5.8 11/30/2005 01:40:00 10.4 0.7 12.2 8.4 10.1 0.8 12.2 8 34 5 25 305 -5.6 0 -5.6 -5.8 11/30/2005 01:50:00 10.5 0.8 12.2 7.6 10.4 0.9 12.2 7.6 36 6 32 305 -5.8 0.1 -5.6 -6 11/30/2005 02:00:00 9.9 0.8 11.5 7.6 9.7 0.8 11.1 7.6 33 5 39 305 -5.9 0 -5.8 -6 11/30/2005 02:10:00 10 0.8 11.8 7.6 9.9 1 12.2 6.8 35 4 31 305 -6 0 -5.8 -6.2 11/30/2005 02:20:00 9.7 0.8 11.5 7.2 9.6 1 11.8 7.2 38 6 32 305 -6.1 0 -5.8 -6.2 11/30/2005 02:30:00 9.9 0.8 11.8 8 9.9 0.8 12.2 7.6 37 5 37 305 -6 0 -5.8 -6.2 11/30/2005 02:40:00 9.7 0.8 11.8 7.6 9.6 0.8 11.8 7.6 32 5 30 305 -5.9 0 -5.8 -6 11/30/2005 02:50:00 9.9 0.8 11.8 7.6 9.8 0.9 11.5 6.8 36 5 42 305 -5.9 0 -5.8 -6 11/30/2005 03:00:00 9.8 0.7 11.5 8 9.8 0.8 11.8 7.2 38 4 43 305 -5.9 0 -5.8 -6 11/30/2005 03:10:00 9.7 0.9 11.5 6.8 9.6 0.9 11.1 7.2 34 5 37 305 -6 0 -5.8 -6.2 11/30/2005 03:20:00 9.6 0.7 11.1 8 9.5 0.8 11.1 6.8 36 6 31 305 -6.1 0 -6 -6.2 11/30/2005 03:30:00 9 0.8 10.7 6.8 8.9 0.9 11.1 6.8 40 5 32 305 -6.1 0 -6 -6.2 11/30/2005 03:40:00 9.3 1 11.8 7.2 9.2 1.1 11.8 7.2 41 5 40 305 -6.1 0 -6 -6.2 11/30/2005 03:50:00 9.1 0.8 10.7 7.2 9 0.8 10.7 6.8 37 5 32 305 -6.1 0 -6 -6.2 11/30/2005 04:00:00 9.8 0.6 11.1 8.4 9.7 0.6 11.5 8 36 5 39 305 -6.1 0 -6 -6.2 11/30/2005 04:10:00 9.6 0.8 11.1 7.2 9.6 0.9 11.5 7.2 37 5 38 305 -6.1 0 -6 -6.2 11/30/2005 04:20:00 9.4 0.7 11.1 7.2 9.3 0.7 11.1 7.2 38 6 36 305 -6.1 0 -6 -6.2 11/30/2005 04:30:00 9.3 0.7 11.1 6.8 9.2 0.8 11.1 6.8 36 6 40 305 -6.1 0 -6 -6.2 11/30/2005 04:40:00 9.1 0.9 11.1 6.8 9 1 11.5 6.5 36 5 33 305 -6.1 0 -6 -6.2 11/30/2005 04:50:00 9.3 0.7 11.1 7.2 9.2 0.8 11.1 7.6 36 5 35 305 -6.2 0 -6 -6.4 11/30/2005 05:00:00 8.7 0.8 10.7 6.5 8.7 0.8 10.7 6.5 38 6 32 305 -6.2 0 -6 -6.4 11/30/2005 05:10:00 8.7 0.6 10.3 6.8 8.6 0.8 10.3 6.5 37 7 39 305 -6.3 0 -6.2 -6.4 11/30/2005 05:20:00 8.7 0.8 10.3 6.8 8.6 0.8 10.7 6.8 32 6 39 305 -6.3 0 -6.2 -6.4 11/30/2005 05:30:00 8.8 0.9 11.5 6.1 8.7 0.9 11.5 5.7 34 7 45 305 -6.4 0 -6.2 -6.4 11/30/2005 05:40:00 8.5 0.8 10.3 6.1 8.4 0.8 10.3 5.7 38 6 31 305 -6.4 0 -6.2 -6.7 11/30/2005 05:50:00 8.6 0.8 9.9 5.7 8.4 0.9 9.9 5.3 34 9 48 305 -6.4 0 -6.2 -6.7 11/30/2005 06:00:00 8.3 0.6 9.9 6.8 8.2 0.8 10.3 6.5 38 6 35 305 -6.5 0 -6.2 -6.7 11/30/2005 06:10:00 8.6 0.6 9.9 6.8 8.5 0.6 10.3 7.2 33 8 41 305 -6.6 0 -6.4 -6.7 11/30/2005 06:20:00 8.1 0.6 9.9 6.5 8 0.7 9.9 6.1 30 5 30 305 -6.6 0 -6.4 -6.9 11/30/2005 06:30:00 8.2 0.6 9.5 6.8 8.1 0.6 9.5 6.5 36 4 40 305 -6.7 0 -6.7 -6.9 11/30/2005 06:40:00 8.4 0.9 10.3 5.7 8.4 1 10.7 6.1 36 7 40 305 -6.7 0 -6.7 -6.9 11/30/2005 06:50:00 8.4 0.8 10.3 6.5 8.3 0.8 10.3 6.1 34 6 31 305 -6.8 0 -6.7 -6.9 11/30/2005 07:00:00 8.5 1 10.7 6.1 8.4 1 11.5 5.7 33 6 30 305 -6.9 0 -6.7 -7.1 11/30/2005 07:10:00 9.1 0.8 10.7 6.8 9.1 0.8 11.1 6.8 26 5 27 305 -6.9 0 -6.7 -7.1 11/30/2005 07:20:00 8.9 0.7 10.3 6.8 8.8 0.8 10.7 6.1 23 5 23 305 -7 0 -6.7 -7.1 11/30/2005 07:30:00 9.5 0.8 11.5 7.6 9.5 0.8 12.2 7.6 20 5 22 305 -7.1 0 -6.9 -7.3 11/30/2005 07:40:00 9 0.9 11.1 6.8 9 0.9 11.5 6.5 24 5 31 305 -7.1 0 -6.9 -7.3 11/30/2005 07:50:00 9.6 0.9 11.5 7.2 9.5 0.8 11.1 7.6 22 5 30 305 -7.1 0 -6.9 -7.3 11/30/2005 08:00:00 9 0.8 11.1 6.8 8.9 0.8 11.1 6.8 21 6 19 305 -7.1 0 -6.9 -7.3 11/30/2005 08:10:00 9.8 1 11.8 7.2 9.8 1 12.2 7.6 19 5 17 305 -7.2 0 -7.1 -7.5 11/30/2005 08:20:00 10.2 0.7 11.8 8 10.2 0.8 12.2 8 20 5 16 305 -7.5 0.1 -7.1 -7.7 11/30/2005 08:30:00 9.8 1 12.2 6.5 9.8 1 12.2 6.8 19 5 15 305 -7.6 0 -7.3 -7.7 11/30/2005 08:40:00 10 0.8 11.8 7.6 10 0.8 12.2 7.2 24 5 18 305 -7.7 0 -7.5 -7.9 11/30/2005 08:50:00 9.9 0.8 11.8 7.2 9.8 0.8 12.2 7.2 25 6 23 305 -7.7 0 -7.7 -7.9 11/30/2005 09:00:00 10 0.7 11.5 8 9.8 0.7 11.5 8 26 5 36 305 -7.8 0 -7.7 -7.9 11/30/2005 09:10:00 10.3 0.9 12.2 7.6 10.1 1 12.6 7.6 23 5 21 305 -7.9 0 -7.7 -8.2 11/30/2005 09:20:00 10.5 0.9 11.8 7.6 10.3 0.9 12.2 7.6 25 5 18 305 -8 0.1 -7.7 -8.2 11/30/2005 09:30:00 10.7 0.8 12.2 8.8 10.6 1 13.3 8 24 7 14 305 -8.2 0 -7.9 -8.4 11/30/2005 09:40:00 10.5 1.1 13 8 10.4 1.1 13 7.6 28 6 37 305 -8.2 0 -7.9 -8.4 11/30/2005 09:50:00 10.8 0.9 12.6 8 10.7 1.1 13 8 28 5 29 305 -8.3 0 -7.9 -8.4 11/30/2005 10:00:00 10.3 0.9 12.2 7.6 10.2 0.9 12.2 6.8 27 6 30 305 -8.5 0 -8.4 -8.6 11/30/2005 10:10:00 10.2 0.8 12.2 8 10.1 0.9 12.2 8 27 5 27 305 -8.6 0.1 -8.4 -8.8 11/30/2005 10:20:00 10.3 0.9 12.2 8 10.2 0.9 12.6 8 27 5 31 305 -8.7 0 -8.4 -8.8 11/30/2005 10:30:00 10.9 0.8 13 8.4 10.8 0.9 13 8.4 25 6 30 305 -8.8 0 -8.6 -9 11/30/2005 10:40:00 10.6 1.1 13.3 8 10.6 1.2 13.3 7.6 26 8 3 305 -9.1 0 -8.8 -9.2 11/30/2005 10:50:00 10.5 0.8 12.6 8.4 10.5 0.9 12.2 8.4 27 5 28 305 -9.2 0 -8.8 -9.4 11/30/2005 11:00:00 10.1 0.8 11.8 8.4 10.1 0.9 12.2 8 30 5 26 305 -9.3 0 -9.2 -9.4 11/30/2005 11:10:00 9.7 1 12.2 7.6 9.5 1 12.2 7.2 28 6 29 305 -9.3 0 -9 -9.2 11/30/2005 11:20:00 9.8 1.1 11.8 7.6 9.7 1.1 12.2 7.2 28 6 23 305 -9.3 0 -9 -9.4 11/30/2005 11:30:00 9.5 0.7 11.5 7.2 9.4 0.8 11.5 7.2 28 5 29 305 -9.3 0 -8.8 -9.4 11/30/2005 11:40:00 9.7 0.8 11.8 7.6 9.6 0.9 11.8 7.2 27 7 19 305 -9.3 0 -9.2 -9.6 11/30/2005 11:50:00 9.7 0.9 12.2 7.6 9.6 0.9 11.8 7.6 25 6 23 305 -9.3 0 -9 -9.6 11/30/2005 12:00:00 9.5 0.9 11.8 6.8 9.5 0.9 12.2 6.8 23 6 30 305 -9.3 0 -9.2 -9.6 11/30/2005 12:10:00 9.6 0.8 11.5 7.2 9.6 0.9 11.5 7.2 25 5 21 305 -9.4 0 -9.2 -9.6 11/30/2005 12:20:00 10 0.8 11.8 8 10 0.8 11.8 8 23 5 29 305 -9.4 0 -9.2 -9.6 11/30/2005 12:30:00 10.2 0.8 12.2 7.6 10.1 0.9 12.2 7.2 22 7 22 305 -9.5 0 -9.2 -9.6 11/30/2005 12:40:00 9.8 0.8 12.2 7.6 9.9 0.8 12.2 8 21 6 27 305 -9.6 0 -9.2 -9.8 11/30/2005 12:50:00 9.7 0.7 11.8 7.2 9.7 0.9 12.2 7.2 22 6 22 305 -9.7 0.1 -9.4 -10 11/30/2005 13:00:00 9.7 0.7 11.1 7.2 9.7 0.7 11.5 7.6 19 5 19 305 -9.7 0 -9.4 -9.8 11/30/2005 13:10:00 9.1 0.8 10.7 7.2 9.1 0.9 11.1 6.8 21 6 13 305 -9.6 0 -9.4 -9.8 11/30/2005 13:20:00 9.5 0.6 11.1 8 9.6 0.8 11.5 8 23 5 22 305 -9.7 0 -9.4 -9.8 11/30/2005 13:30:00 9 0.7 11.1 7.2 9.1 0.8 11.1 7.2 25 5 30 305 -9.6 0 -9.2 -9.6 11/30/2005 13:40:00 9.2 0.7 11.1 7.6 9.2 0.7 11.1 7.6 23 8 20 305 -9.6 0 -9.4 -9.8 11/30/2005 13:50:00 9.1 0.9 10.7 6.5 9.2 0.9 11.1 6.5 24 5 32 305 -9.6 0 -9.2 -9.8 11/30/2005 14:00:00 8.7 0.6 10.7 6.8 8.7 0.6 10.7 6.8 27 6 32 305 -9.8 0 -9.6 -10 11/30/2005 14:10:00 9.1 0.7 11.1 7.2 9.2 0.8 11.5 7.2 26 5 20 305 -9.7 0 -9.6 -9.8 11/30/2005 14:20:00 8.8 0.7 11.1 6.8 8.8 0.7 10.7 6.8 27 5 25 305 -9.7 0 -9.4 -9.8 11/30/2005 14:30:00 8.7 0.6 10.7 7.2 8.7 0.7 11.1 7.2 25 4 29 305 -9.7 0 -9.4 -9.8 11/30/2005 14:40:00 9 0.7 10.3 6.5 9 0.8 10.7 6.1 22 6 20 305 -9.7 0 -9.6 -9.8 11/30/2005 14:50:00 9.4 0.8 11.8 7.2 9.4 0.8 11.8 7.2 22 6 13 305 -9.7 0 -9.4 -9.8 11/30/2005 15:00:00 10 0.8 11.8 7.6 10 0.9 12.2 8 24 5 18 305 -9.8 0 -9.6 -10 11/30/2005 15:10:00 10.5 0.5 11.8 9.1 10.6 0.6 12.2 9.1 24 5 17 305 -9.9 0 -9.6 -10 11/30/2005 15:20:00 10.1 0.6 11.8 8.4 10.1 0.7 11.8 8 21 5 17 305 -9.8 0 -9.6 -10 11/30/2005 15:30:00 10.1 0.9 12.2 7.2 10.1 1 12.2 7.2 23 6 16 305 -9.9 0 -9.6 -10 11/30/2005 15:40:00 10.4 0.8 12.6 8 10.5 0.9 12.6 8 17 4 19 305 -10 0 -9.6 -10.2 11/30/2005 15:50:00 10.5 0.7 12.2 8.8 10.4 0.9 13 8 18 5 14 305 -10 0 -9.8 -10.2 11/30/2005 16:00:00 10.7 0.8 12.6 8.4 10.6 0.9 13 8.4 22 5 18 305 -10 0.1 -9.8 -10.2 11/30/2005 16:10:00 10.9 0.9 14.5 8.4 11 1 14.5 8.4 16 6 25 305 -10.1 0 -9.8 -10.4 11/30/2005 16:20:00 11.8 1 14.5 9.5 11.9 1 14.9 9.5 15 5 16 305 -10.3 0 -10 -10.4 11/30/2005 16:30:00 12.1 0.9 15.6 9.9 12.2 1 16.1 9.5 13 5 11 305 -10.5 0 -10.4 -10.9 11/30/2005 16:40:00 12.1 1 14.5 9.5 12.2 1 14.5 9.1 10 6 4 305 -10.8 0 -10.7 -11.1 11/30/2005 16:50:00 11.8 0.9 14.1 8.8 11.9 1 14.5 9.1 13 5 14 305 -11.1 0 -10.9 -11.3 11/30/2005 17:00:00 11.7 0.9 13.7 9.1 11.8 1 14.5 9.1 10 6 24 305 -11.2 0 -10.9 -11.5 11/30/2005 17:10:00 10.6 1 12.6 8 10.7 1 13 8 11 6 12 305 -11.2 0 -10.9 -11.5 11/30/2005 17:20:00 10.6 0.8 12.6 8 10.6 0.9 13 8 11 5 12 305 -11.3 0.1 -10.7 -11.5 11/30/2005 17:30:00 10.6 1 13.3 8 10.7 1 13.7 8 8 5 12 305 -11.2 0 -10.4 -11.3 11/30/2005 17:40:00 10.6 1 13.7 8 10.7 1 13.7 7.2 13 5 8 305 -11.1 0 -10.9 -11.3 11/30/2005 17:50:00 9.7 0.8 12.2 7.2 9.8 0.9 12.2 7.6 17 7 27 305 -11.1 0 -10.7 -11.3 11/30/2005 18:00:00 9.6 0.7 11.8 7.2 9.7 0.7 12.2 8 18 7 23 305 -10.9 0 -10.7 -11.1 11/30/2005 18:10:00 9.5 0.9 11.5 6.1 9.5 0.9 11.5 6.1 15 5 9 305 -10.8 0 -10.4 -10.9 11/30/2005 18:20:00 9.6 1 11.8 6.8 9.6 1 12.2 7.2 19 5 18 305 -10.6 0.1 -10.4 -10.9 11/30/2005 18:30:00 9.8 0.9 12.2 7.2 9.8 1 12.2 7.2 17 6 30 305 -10.5 0 -10.4 -10.9 11/30/2005 18:40:00 10.1 0.9 12.2 7.6 10.1 1 12.6 7.6 21 5 23 305 -10.4 0 -10.2 -10.9 11/30/2005 18:50:00 10.2 0.9 12.2 7.6 10.2 0.9 12.6 8 16 4 18 305 -10.5 0 -10.4 -10.9 11/30/2005 19:00:00 10.5 0.9 12.6 8.4 10.7 1 13 8.4 16 5 16 305 -10.4 0 -10.2 -10.9 11/30/2005 19:10:00 10.7 1 13.3 8 10.6 1.1 13 7.6 14 5 21 305 -10.5 0 -10.4 -10.9 11/30/2005 19:20:00 11.1 1.1 14.1 8 11.2 1.1 14.5 8.4 19 6 19 305 -10.7 0.1 -10.4 -10.9 11/30/2005 19:30:00 10.7 1.1 13.3 7.6 10.7 1.1 13.7 8.4 15 9 18 305 -10.6 0.1 -10.2 -10.9 11/30/2005 19:40:00 10.8 0.9 13.7 8.4 10.8 1 13.7 7.2 8 8 22 305 -10.5 0.2 -10 -10.9 11/30/2005 19:50:00 10.9 0.8 13 8.8 11.1 1 13.3 8.8 4 5 0 305 -10.9 0 -10.7 -11.1 11/30/2005 20:00:00 10.1 0.9 12.2 7.6 10.3 0.9 12.2 8 6 4 2 305 -11 0 -10.7 -11.3 11/30/2005 20:10:00 10.4 1 12.2 8 10.6 1.1 13 8 8 7 13 305 -11 0 -10.9 -11.3 11/30/2005 20:20:00 10.1 1.2 13.3 7.2 10.1 1.2 13 6.8 11 7 356 305 -11 0.1 -10.4 -11.3 11/30/2005 20:30:00 10.2 1 11.8 7.6 10.3 1.1 12.2 7.2 2 8 358 305 -10.9 0 -10.9 -11.3 11/30/2005 20:40:00 10.4 0.7 12.2 8.4 10.6 0.8 12.6 8.4 4 5 356 305 -11 0 -10.9 -11.3 11/30/2005 20:50:00 10.3 0.8 12.2 8 10.5 0.8 12.6 8.4 5 6 357 305 -11.1 0.1 -10.9 -11.5 11/30/2005 21:00:00 10.5 0.9 12.2 8 10.7 1 13 7.6 7 8 7 305 -11.3 0 -11.1 -11.5 11/30/2005 21:10:00 11.1 0.8 13.3 8.8 11.2 0.8 13.3 9.1 7 6 4 305 -11.3 0 -11.3 -11.5 11/30/2005 21:20:00 10.5 1 12.6 8 10.6 1 12.6 8 8 6 3 305 -11.4 0 -11.3 -11.5 11/30/2005 21:30:00 10.8 0.9 13 8.4 10.9 1 13.3 8 3 8 8 305 -11.3 0.1 -10.9 -11.5 11/30/2005 21:40:00 10.1 0.8 12.2 8.4 10.2 1 12.6 7.2 5 6 6 305 -11.4 0 -11.3 -11.7 11/30/2005 21:50:00 10.4 1 13 8 10.6 1 13.7 8.4 3 7 1 305 -11.4 0 -11.3 -11.7 11/30/2005 22:00:00 10.5 1.1 13.7 8 10.7 1.1 13.7 8.4 2 7 355 305 -11.5 0 -11.3 -11.7 11/30/2005 22:10:00 10.8 1 13.3 8 11 1.1 13.7 8 0 8 4 305 -11.5 0 -11.3 -11.7 11/30/2005 22:20:00 9.9 1.1 12.6 6.8 10 1.1 12.6 6.8 0 7 359 305 -11.5 0 -11.3 -11.7 11/30/2005 22:30:00 10.2 1.1 12.6 7.6 10.4 1.1 13.3 8 2 6 358 305 -11.6 0 -11.5 -11.9 11/30/2005 22:40:00 10.2 1.2 13.3 6.8 10.3 1.3 13.7 6.8 8 9 17 305 -11.5 0 -11.5 -11.9 11/30/2005 22:50:00 11.5 1.2 14.5 7.6 11.5 1.2 14.1 8.8 9 8 12 305 -11.5 0 -11.3 -11.7 11/30/2005 23:00:00 11.2 1 13.7 8 11.4 1 14.1 8.4 9 6 11 305 -11.7 0 -11.5 -11.9 11/30/2005 23:10:00 11.1 1 13.3 8.8 11.2 1.1 13.7 8.8 6 7 13 305 -11.7 0.1 -11.5 -12.1 11/30/2005 23:20:00 12 1.1 14.5 8 12 1.2 14.9 8 6 6 9 305 -11.9 0 -11.7 -12.1 11/30/2005 23:30:00 12.3 1 14.9 9.5 12.5 1.2 15.3 9.1 6 7 13 305 -11.9 0.1 -11.5 -12.3 11/30/2005 23:40:00 11.5 1.1 14.9 8.8 11.6 1.2 14.9 8.8 10 5 7 305 -11.8 0.1 -11.5 -12.1 11/30/2005 23:50:00 12.7 1 14.9 9.5 12.7 1 15.3 9.9 11 5 11 305 -11.9 0.1 -11.7 -12.1 12/01/2005 00:00:00 12.1 1.1 15.3 9.5 12.2 1.2 15.3 8.8 11 6 11 305 -12 0 -11.7 -12.5 12/01/2005 00:10:00 12.3 0.9 14.5 9.5 12.4 1 15.3 8.8 9 6 8 305 -12.1 0 -11.9 -12.3 12/01/2005 00:20:00 12.4 1.1 14.9 9.5 12.6 1.2 15.3 9.1 5 7 357 305 -12.2 0.1 -11.9 -12.5 12/01/2005 00:30:00 11.9 0.8 14.1 9.5 12 0.9 14.5 9.5 6 6 11 305 -12 0 -11.7 -12.3 12/01/2005 00:40:00 12.3 1.2 14.5 8.8 12.5 1.2 15.6 8.4 4 5 2 305 -12.2 0.1 -11.9 -12.5 12/01/2005 00:50:00 12.9 1 15.6 9.9 13.2 1.1 16.1 9.9 3 4 6 305 -12.3 0.1 -12.1 -12.5 12/01/2005 01:00:00 12.6 1 15.3 10.7 12.8 1 15.3 10.7 5 6 357 305 -12.2 0.2 -11.5 -12.5 12/01/2005 01:10:00 13.1 0.9 15.6 10.3 13.3 1 15.6 9.5 5 7 3 305 -12.4 0.1 -11.9 -12.5 12/01/2005 01:20:00 12.3 1.2 15.6 9.5 12.6 1.2 16.1 9.1 3 7 3 305 -12.5 0.1 -11.9 -12.7 12/01/2005 01:30:00 12.2 1 14.5 9.1 12.2 1.1 14.9 9.1 13 5 14 305 -12.4 0.1 -11.7 -12.7 12/01/2005 01:40:00 12.6 1 15.3 9.5 12.6 1.1 14.9 9.5 14 5 18 305 -12.2 0.1 -11.7 -12.5 12/01/2005 01:50:00 12.2 1 14.9 9.9 12.3 1 14.9 9.9 14 4 7 305 -12.3 0 -12.1 -12.5 12/01/2005 02:00:00 11.9 0.8 14.5 9.5 12 1 14.5 9.1 11 6 16 305 -12.3 0.1 -12.1 -12.5 12/01/2005 02:10:00 12.2 1.1 15.6 9.5 12.3 1.2 15.6 9.1 14 6 14 305 -12.4 0.1 -12.1 -12.7 12/01/2005 02:20:00 13.1 1.1 16.4 10.3 13.2 1.2 16.4 9.1 6 7 14 305 -12.6 0 -12.1 -12.9 12/01/2005 02:30:00 13.2 1.1 15.6 9.9 13.3 1.2 16.4 9.9 10 8 351 305 -12.5 0 -12.1 -12.7 12/01/2005 02:40:00 13.8 1.1 17.2 11.5 13.8 1.2 17.6 10.3 11 5 13 305 -12.5 0 -12.1 -12.7 12/01/2005 02:50:00 13.2 1.2 16.1 9.1 13.3 1.3 16.1 9.5 10 6 22 305 -12.4 0.1 -11.9 -12.5 12/01/2005 03:00:00 13.8 1 16.8 10.3 13.9 1.1 16.8 10.3 12 7 12 305 -12.6 0.1 -12.1 -12.9 12/01/2005 03:10:00 13.5 1.2 16.4 10.3 13.7 1.3 16.8 9.1 5 5 4 305 -12.6 0.1 -12.1 -12.9 12/01/2005 03:20:00 13.2 1.1 16.1 9.5 13.4 1.1 16.1 11.1 5 6 359 305 -12.6 0 -12.1 -12.9 12/01/2005 03:30:00 13.8 1.1 16.8 10.3 13.9 1.3 16.8 10.3 5 7 7 305 -12.5 0 -12.1 -12.9 12/01/2005 03:40:00 13.7 0.8 16.4 11.5 13.9 0.9 16.1 11.5 7 5 8 305 -12.7 0 -12.5 -12.9 12/01/2005 03:50:00 13.6 1.2 16.1 10.3 13.8 1.3 16.4 9.9 5 6 352 305 -12.7 0 -12.1 -12.9 12/01/2005 04:00:00 13 0.9 15.3 10.3 13.2 1 15.6 10.3 2 7 359 305 -12.6 0 -12.1 -12.9 12/01/2005 04:10:00 13.6 1.1 16.4 9.9 13.8 1.1 16.8 10.7 0 5 359 305 -12.7 0 -12.1 -12.9 12/01/2005 04:20:00 14.1 1 17.2 10.7 14.3 1.1 16.8 10.3 1 6 354 305 -12.5 0.1 -12.1 -12.9 12/01/2005 04:30:00 13.8 1.2 17.2 10.7 13.9 1.2 17.6 11.1 358 5 352 305 -12.5 0.1 -12.1 -12.7 12/01/2005 04:40:00 14 1 16.4 11.1 14.2 1.1 17.2 11.5 1 5 356 305 -12.5 0 -12.3 -12.7 12/01/2005 04:50:00 13.9 1.2 17.2 10.7 14.1 1.3 16.8 10.7 0 5 4 305 -12.3 0 -12.1 -12.5 12/01/2005 05:00:00 13.8 1.1 16.1 10.3 13.9 1.2 16.4 10.3 359 6 2 305 -12.4 0.1 -12.1 -12.7 12/01/2005 05:10:00 14.3 1.2 17.9 10.3 14.5 1.2 18.7 11.5 0 6 357 305 -12.3 0.1 -12.1 -12.5 12/01/2005 05:20:00 14.3 1.1 17.6 11.5 14.5 1.1 17.6 11.1 359 6 7 305 -12.2 0 -12.1 -12.5 12/01/2005 05:30:00 14.5 1.4 17.6 11.5 14.7 1.5 18.3 11.1 3 4 2 305 -12.3 0 -12.1 -12.5 12/01/2005 05:40:00 13.7 1.2 16.8 10.3 13.8 1.2 16.8 10.7 2 6 0 305 -12.1 0 -11.9 -12.5 12/01/2005 05:50:00 14.9 1.1 17.9 12.2 15.1 1.2 17.9 11.5 0 4 2 305 -12.1 0 -11.9 -12.3 12/01/2005 06:00:00 14.6 1.2 18.3 11.8 14.8 1.2 18.7 11.8 359 6 358 305 -12 0 -11.7 -12.3 12/01/2005 06:10:00 15.5 1.2 18.3 12.6 15.6 1.3 18.3 11.8 0 7 352 305 -11.9 0.1 -11.5 -12.1 12/01/2005 06:20:00 15.7 1.6 19.1 11.1 15.8 1.7 19.9 11.5 0 5 2 305 -11.7 0.1 -11.5 -12.1 12/01/2005 06:30:00 15.8 1.4 19.5 12.6 15.8 1.5 19.9 11.8 2 6 351 305 -11.7 0.2 -11.3 -12.1 12/01/2005 06:40:00 16 1.4 19.1 12.6 16.1 1.5 19.1 12.2 358 5 357 305 -11.6 0.1 -11.3 -12.1 12/01/2005 06:50:00 15.9 1.5 19.5 11.8 16 1.5 19.9 12.2 359 6 359 305 -11.5 0.1 -10.9 -11.9 12/01/2005 07:00:00 16.2 1.3 19.1 12.6 16.3 1.5 19.5 11.8 358 5 2 305 -11.5 0.1 -10.9 -11.9 12/01/2005 07:10:00 15.5 1.4 18.7 11.1 15.5 1.5 18.7 11.1 1 5 0 305 -11.4 0.1 -10.9 -11.7 12/01/2005 07:20:00 16.1 1.2 19.1 12.2 16.2 1.3 19.5 12.2 359 5 358 305 -11.3 0.1 -10.9 -11.5 12/01/2005 07:30:00 15.9 1.7 20.2 11.1 16 1.7 19.5 11.1 1 6 358 305 -11 0.2 -10.7 -11.5 12/01/2005 07:40:00 16.4 1.6 19.5 12.6 16.5 1.6 20.2 13 1 5 5 305 -10.9 0 -10.7 -11.3 12/01/2005 07:50:00 16.1 1.4 19.9 12.2 16.2 1.5 19.5 12.2 0 6 352 305 -10.8 0.1 -10.4 -11.3 12/01/2005 08:00:00 16.5 1.7 20.2 11.8 16.5 1.8 20.6 11.8 0 5 356 305 -10.5 0.1 -10.2 -10.9 12/01/2005 08:10:00 17.2 1.5 20.2 13 17.2 1.5 20.6 12.6 0 6 355 305 -10.4 0 -10 -10.9 12/01/2005 08:20:00 17.1 1.4 21 13.7 17 1.5 21.8 13.3 359 6 352 305 -10.4 0 -10 -10.9 12/01/2005 08:30:00 18.3 1.5 21.4 14.5 18.3 1.6 21.8 13 358 4 359 305 -10.2 0.1 -9.8 -10.4 12/01/2005 08:40:00 18.6 1.6 21.8 13.7 18.6 1.7 21.8 13.3 0 6 0 305 -10.2 0.1 -9.6 -10.4 12/01/2005 08:50:00 18.7 1.3 21.8 15.3 18.7 1.3 22.1 14.1 358 5 4 305 -10.1 0 -9.6 -10.4 12/01/2005 09:00:00 18.6 1.5 22.1 13.3 18.5 1.5 22.1 14.1 359 6 356 305 -9.9 0.1 -9.4 -10.4 12/01/2005 09:10:00 17.7 1.7 22.6 13.7 17.8 1.8 22.6 13 358 5 2 305 -9.9 0.1 -9.2 -10.2 12/01/2005 09:20:00 18.5 1.3 21.8 14.9 18.5 1.5 22.1 14.9 356 5 358 305 -10 0 -9.6 -10.2 12/01/2005 09:30:00 19.1 1.6 23.3 14.9 19.2 1.7 24 14.9 355 5 354 305 -10 0.1 -9.6 -10.4 12/01/2005 09:40:00 19.1 1.6 23.3 15.3 19.2 1.7 23.3 14.5 353 4 353 305 -10 0.1 -9.4 -10.4 12/01/2005 09:50:00 19.5 1.7 23.7 15.3 19.4 1.8 24 15.3 355 5 356 305 -10 0 -9.6 -10.2 12/01/2005 10:00:00 20 1.8 23.3 13.7 20.1 1.9 23.7 14.5 357 5 352 305 -10.1 0.1 -9.6 -10.4 12/01/2005 10:10:00 19.4 1.6 22.6 15.3 19.4 1.7 23.3 14.9 359 4 11 305 -9.9 0 -9.4 -10 12/01/2005 10:20:00 19.9 1.9 23.7 12.6 19.9 1.9 24.4 14.1 1 6 7 305 -10 0 -9.6 -10.2 12/01/2005 10:30:00 19.3 1.5 22.6 15.3 19.4 1.6 23.3 15.3 3 5 0 305 -10 0 -9.6 -10.2 12/01/2005 10:40:00 19.2 1.7 22.9 14.5 19.2 1.7 22.9 13.3 359 5 5 305 -10.1 0.1 -9.6 -10.4 12/01/2005 10:50:00 19.7 1.5 23.3 14.9 19.6 1.6 23.7 14.5 359 5 358 305 -10.3 0.1 -9.8 -10.7 12/01/2005 11:00:00 18.8 1.5 22.6 14.5 18.8 1.5 22.6 14.9 358 5 0 305 -10.4 0 -10 -10.7 12/01/2005 11:10:00 19.1 1.8 22.9 13.3 19.2 1.9 23.7 13.7 356 5 352 305 -10.4 0.1 -10 -10.9 12/01/2005 11:20:00 17.6 1.5 21.8 13.3 17.7 1.5 21.8 13.7 2 6 0 305 -10.4 0.2 -9.8 -10.9 12/01/2005 11:30:00 18.3 1.4 21.8 14.5 18.3 1.5 21.8 14.9 1 5 0 305 -10.4 0 -10 -10.7 12/01/2005 11:40:00 17.9 1.7 21.4 13.3 17.9 1.7 21.8 13.3 358 5 358 305 -10.5 0 -10 -10.9 12/01/2005 11:50:00 17.6 1.4 21.4 14.1 17.6 1.4 21.4 13.3 0 5 359 305 -10.5 0 -10.2 -10.9 12/01/2005 12:00:00 17.5 1.3 20.6 13.7 17.5 1.4 20.6 14.1 1 5 0 305 -10.5 0 -10.2 -10.9 12/01/2005 12:10:00 17.7 1.3 20.6 14.1 17.6 1.5 21 13.7 1 6 5 305 -10.4 0 -10 -10.9 12/01/2005 12:20:00 17.3 1.3 21.4 12.6 17.5 1.4 21 12.6 359 5 354 305 -10.4 0 -10 -10.7 12/01/2005 12:30:00 17.5 1.4 20.2 12.6 17.6 1.5 20.6 13 2 6 355 305 -10.5 0.1 -10 -10.9 12/01/2005 12:40:00 17.4 1.3 20.6 13 17.5 1.3 21 13.3 0 5 2 305 -10.6 0.1 -10 -10.9 12/01/2005 12:50:00 17.2 1.5 20.6 12.6 17.3 1.5 21 13 3 5 2 305 -10.5 0.1 -10 -10.9 12/01/2005 13:00:00 16.9 1.5 20.6 13 16.8 1.7 21 13 4 6 0 305 -10.5 0 -10.2 -10.9 12/01/2005 13:10:00 16.3 1.5 19.9 12.6 16.4 1.6 19.5 12.2 2 6 353 305 -10.7 0.1 -10 -10.9 12/01/2005 13:20:00 16.4 1.4 20.2 12.6 16.5 1.6 21.8 13 3 6 10 305 -10.5 0 -10.2 -10.9 12/01/2005 13:30:00 15.4 1.3 18.3 11.8 15.6 1.4 18.7 11.5 358 6 3 305 -10.7 0.1 -10.4 -10.9 12/01/2005 13:40:00 16 1 17.9 13.3 16.1 1.1 18.7 13.3 359 6 2 305 -10.7 0 -10.2 -10.9 12/01/2005 13:50:00 15.1 1.2 18.3 11.8 15.1 1.3 18.7 11.8 359 6 4 305 -10.6 0 -10.2 -10.9 12/01/2005 14:00:00 14.8 1.3 18.3 11.1 14.9 1.5 18.7 10.7 359 6 353 305 -10.5 0 -10.2 -10.9 12/01/2005 14:10:00 14.8 1.5 19.1 11.1 14.9 1.5 19.1 11.5 358 7 358 305 -10.4 0 -10 -10.7 12/01/2005 14:20:00 15 1.2 18.3 11.5 15 1.3 18.3 10.7 359 7 357 305 -10.6 0.1 -10.2 -10.9 12/01/2005 14:30:00 15 1.3 18.3 11.5 15.1 1.4 18.7 11.1 352 5 355 305 -10.7 0.1 -10.2 -11.1 12/01/2005 14:40:00 15.2 1.3 18.7 11.8 15.3 1.5 18.7 11.5 352 4 354 305 -10.9 0.1 -10.4 -11.3 12/01/2005 14:50:00 15.9 1.2 18.3 11.8 16.1 1.2 18.7 11.8 351 5 343 305 -10.9 0 -10.7 -11.3 12/01/2005 15:00:00 15.3 1.3 19.1 10.3 15.5 1.5 19.1 9.9 352 6 347 305 -10.9 0 -10.4 -11.3 12/01/2005 15:10:00 15.6 1.5 19.1 11.1 15.9 1.5 19.5 11.1 351 4 353 305 -10.9 0 -10.7 -11.3 12/01/2005 15:20:00 15.3 1.4 18.7 11.1 15.6 1.5 19.1 11.5 351 6 356 305 -11 0 -10.4 -11.3 12/01/2005 15:30:00 15.3 1.3 17.9 11.8 15.5 1.3 18.3 12.6 350 6 352 305 -11 0.1 -10.7 -11.3 12/01/2005 15:40:00 15.2 1.2 17.9 12.6 15.4 1.3 18.3 12.2 350 5 351 305 -11 0.1 -10.7 -11.3 12/01/2005 15:50:00 15.5 1.2 17.9 11.5 15.7 1.3 18.7 11.8 352 5 355 305 -11.1 0 -10.7 -11.3 12/01/2005 16:00:00 15.5 1.3 18.7 12.2 15.6 1.3 18.7 11.8 350 6 341 305 -11 0.1 -10.4 -11.3 12/01/2005 16:10:00 16 1.4 19.1 12.2 16.1 1.5 19.5 12.2 352 6 351 305 -10.8 0.1 -10.4 -11.3 12/01/2005 16:20:00 17.1 1.4 19.9 12.6 17.2 1.5 20.2 11.8 354 5 350 305 -11.1 0.1 -10.7 -11.3 12/01/2005 16:30:00 16.9 1.5 20.6 12.6 17 1.5 20.2 13 350 6 341 305 -11 0.2 -10.4 -11.5 12/01/2005 16:40:00 17 1.3 19.9 13.7 17 1.4 20.2 13 350 6 352 305 -11.2 0.1 -10.9 -11.5 12/01/2005 16:50:00 16.2 1.5 19.5 12.6 16.4 1.7 19.9 12.2 353 5 357 305 -11.3 0.1 -10.9 -11.7 12/01/2005 17:00:00 16.2 1.3 19.1 12.2 16.2 1.4 20.2 12.2 353 6 352 305 -11.2 0.1 -10.9 -11.5 12/01/2005 17:10:00 17.3 1.2 19.9 13.3 17.4 1.2 20.2 14.1 357 6 4 305 -11.4 0.1 -11.1 -11.5 12/01/2005 17:20:00 17.2 1.4 19.9 13.3 17.3 1.5 20.2 13.3 356 5 358 305 -11.1 0.1 -10.7 -11.5 12/01/2005 17:30:00 17.9 1.2 21 14.1 18.1 1.3 21 14.1 354 5 352 305 -11.4 0 -11.1 -11.7 12/01/2005 17:40:00 16.7 1.3 19.9 12.2 16.8 1.5 19.9 12.2 354 5 353 305 -11.3 0.1 -10.9 -11.7 12/01/2005 17:50:00 16.5 1.5 19.9 11.8 16.7 1.5 20.2 11.8 353 5 355 305 -11.3 0.1 -10.9 -11.5 12/01/2005 18:00:00 16.8 1.2 19.5 12.6 17 1.4 20.6 12.2 354 5 357 305 -11.3 0.1 -10.9 -11.7 12/01/2005 18:10:00 16.8 1.5 20.2 12.6 16.9 1.5 20.2 12.6 356 5 0 305 -11.3 0.1 -10.9 -11.5 12/01/2005 18:20:00 17.9 1.7 21 13 18 1.9 21.4 11.8 353 5 350 305 -11.2 0.2 -10.7 -11.7 12/01/2005 18:30:00 17.9 1.3 21.4 14.5 18 1.4 21.8 13.7 354 5 351 305 -11.3 0.1 -11.1 -11.7 12/01/2005 18:40:00 17.6 1.3 20.6 13 17.8 1.3 20.6 13.7 352 5 355 305 -11.2 0.1 -10.9 -11.7 12/01/2005 18:50:00 17.8 1.6 21.4 13.3 17.9 1.6 21.4 13.3 353 6 350 305 -11.2 0.1 -10.7 -11.5 12/01/2005 19:00:00 17.3 1.3 20.2 13 17.4 1.3 20.2 12.6 354 6 349 305 -11.3 0.1 -10.9 -11.5 12/01/2005 19:10:00 16 1.5 19.5 11.8 16 1.5 19.9 11.5 354 6 357 305 -11.3 0.1 -10.9 -11.5 12/01/2005 19:20:00 16.6 1.3 19.5 12.2 16.7 1.5 20.6 13 355 4 351 305 -11.3 0.1 -10.9 -11.5 12/01/2005 19:30:00 16.6 1.5 19.9 12.6 16.8 1.6 20.2 13 359 6 351 305 -11.2 0 -10.9 -11.5 12/01/2005 19:40:00 17.1 1.4 21 13 17.1 1.6 20.6 13 358 6 0 305 -11 0.1 -10.7 -11.5 12/01/2005 19:50:00 16.7 1.7 20.2 11.8 16.9 1.7 20.6 12.6 1 6 6 305 -10.9 0.1 -10.4 -11.3 12/01/2005 20:00:00 17 1.5 20.6 12.6 17 1.5 20.6 12.6 357 5 352 305 -11 0 -10.7 -11.3 12/01/2005 20:10:00 16.5 1.5 19.9 12.6 16.6 1.7 20.2 13 356 6 349 305 -10.9 0.1 -10.4 -11.3 12/01/2005 20:20:00 16.8 1.5 20.2 13 16.8 1.5 20.2 12.2 358 6 355 305 -10.9 0 -10.4 -11.3 12/01/2005 20:30:00 18.1 1.5 21.8 12.2 18.3 1.5 21.8 13 353 5 356 305 -10.9 0.1 -10.4 -11.3 12/01/2005 20:40:00 18.2 1.6 21.8 13.7 18.4 1.7 21.8 13.3 356 5 356 305 -10.9 0.1 -10.4 -11.3 12/01/2005 20:50:00 18.4 1.4 22.1 14.5 18.4 1.5 21.8 13.3 0 7 0 305 -11 0 -10.4 -11.3 12/01/2005 21:00:00 18.4 1.3 21.4 15.6 18.4 1.4 21.8 14.9 355 5 358 305 -11 0.1 -10.4 -11.3 12/01/2005 21:10:00 17.3 1.8 21 12.2 17.3 2 21.4 12.6 358 5 356 305 -10.9 0.1 -10.4 -11.3 12/01/2005 21:20:00 17.7 1.5 21 14.1 17.8 1.5 21.4 13.3 358 5 357 305 -11 0.1 -10.4 -11.3 12/01/2005 21:30:00 17.9 1.7 22.1 12.6 18 1.8 22.6 12.2 359 5 356 305 -10.9 0 -10.4 -11.3 12/01/2005 21:40:00 17.7 1.5 21.4 13 17.8 1.5 21.4 13.3 3 5 359 305 -11 0 -10.4 -11.3 12/01/2005 21:50:00 17.7 1.2 20.2 13.7 17.8 1.2 21 13 2 6 4 305 -11.2 0.1 -10.9 -11.5 12/01/2005 22:00:00 17.1 1.5 20.2 11.8 17.2 1.7 21 12.2 0 6 6 305 -11 0 -10.7 -11.5 12/01/2005 22:10:00 16.5 1.8 19.9 11.5 16.5 1.7 20.2 11.1 4 5 4 305 -10.9 0.1 -10.4 -11.3 12/01/2005 22:20:00 18 1.2 21 14.1 18.1 1.2 21.8 14.1 2 5 9 305 -11 0 -10.7 -11.3 12/01/2005 22:30:00 17.3 1.7 20.2 12.2 17.5 1.7 20.6 11.8 2 5 4 305 -11.1 0.1 -10.7 -11.5 12/01/2005 22:40:00 17 1.3 21.4 12.6 17.1 1.3 20.6 13.3 2 5 358 305 -11.1 0.1 -10.9 -11.5 12/01/2005 22:50:00 16.8 1.4 20.6 13.3 16.8 1.5 20.2 12.6 1 6 352 305 -11.2 0 -10.9 -11.5 12/01/2005 23:00:00 17.1 1.5 20.6 13.3 17.2 1.6 20.6 13 2 5 359 305 -11.1 0.1 -10.7 -11.5 12/01/2005 23:10:00 17.2 1.5 22.1 12.6 17.3 1.7 22.1 12.6 3 5 2 305 -11.1 0 -10.9 -11.3 12/01/2005 23:20:00 17.3 1.5 21.4 12.6 17.3 1.6 21.4 12.6 2 5 6 305 -11.1 0.1 -10.7 -11.5 12/01/2005 23:30:00 17.2 1.4 21 13 17.3 1.5 21.4 13 2 5 357 305 -11.3 0.1 -10.9 -11.5 12/01/2005 23:40:00 16.9 1.1 20.2 14.1 17 1.3 19.9 13.3 4 4 0 305 -11.3 0.1 -10.9 -11.5 12/01/2005 23:50:00 16.7 1.5 19.9 12.2 16.7 1.5 20.2 11.5 3 5 4 305 -11.2 0.1 -10.9 -11.5 12/02/2005 00:00:00 16.5 1.5 19.5 12.2 16.7 1.6 19.9 12.6 6 7 359 305 -11.2 0.1 -10.9 -11.5 12/02/2005 00:10:00 17.2 1.3 20.2 13.3 17.2 1.5 21 11.8 4 5 0 305 -11.3 0.1 -10.9 -11.7 12/02/2005 00:20:00 16.8 1.4 20.2 13.3 16.9 1.5 20.6 13.3 2 5 357 305 -11.3 0.1 -10.9 -11.7 12/02/2005 00:30:00 16.4 1.4 19.1 11.8 16.5 1.5 20.2 12.6 4 7 7 305 -11.3 0.1 -10.9 -11.5 12/02/2005 00:40:00 17.4 1.3 20.6 13.7 17.5 1.5 21 12.6 359 4 356 305 -11.4 0 -11.1 -11.7 12/02/2005 00:50:00 16.9 1.7 20.6 12.2 17 1.7 20.6 12.2 1 5 356 305 -11.5 0 -11.3 -11.7 12/02/2005 01:00:00 17.4 1.3 20.6 13.7 17.5 1.5 21.4 13.3 3 4 7 305 -11.5 0 -11.3 -11.7 12/02/2005 01:10:00 15.9 1.5 19.5 10.3 16 1.7 19.5 11.5 5 7 8 305 -11.4 0.1 -10.9 -11.7 12/02/2005 01:20:00 16.4 1.2 19.5 13 16.4 1.3 19.9 13.3 359 5 358 305 -11.4 0 -11.1 -11.7 12/02/2005 01:30:00 16.8 1.3 19.9 12.6 16.9 1.5 19.9 13 2 5 0 305 -11.4 0.1 -11.1 -11.7 12/02/2005 01:40:00 16.5 1.6 19.9 11.1 16.4 1.6 20.2 11.8 5 5 7 305 -11.4 0.1 -10.9 -11.7 12/02/2005 01:50:00 16.2 1.5 19.5 11.1 16.3 1.5 19.5 11.5 4 5 3 305 -11.4 0.1 -10.9 -11.7 12/02/2005 02:00:00 16 1.7 19.9 12.2 16.1 1.7 19.9 11.8 5 5 5 305 -11.4 0.1 -10.9 -11.7 12/02/2005 02:10:00 16.9 1.3 19.5 13 17 1.5 19.9 12.6 4 6 4 305 -11.5 0.1 -11.3 -11.9 12/02/2005 02:20:00 16.6 1.8 19.9 11.8 16.7 1.7 20.6 12.2 6 7 0 305 -11.4 0.1 -10.9 -11.7 12/02/2005 02:30:00 17.6 1.3 20.6 13.3 17.5 1.4 20.6 12.6 15 5 31 305 -11.5 0 -11.1 -11.7 12/02/2005 02:40:00 17.8 1.5 20.6 13.3 17.7 1.5 21 13.3 18 4 15 305 -11.5 0.1 -11.1 -11.7 12/02/2005 02:50:00 18.1 1.4 21 13.7 18 1.5 21 13.7 16 5 17 305 -11.5 0 -11.1 -11.9 12/02/2005 03:00:00 18.1 1.7 22.1 13 18.1 1.7 21.8 13 15 4 12 305 -11.5 0 -11.3 -11.7 12/02/2005 03:10:00 18.2 1.6 22.9 13.3 18.1 1.6 22.9 14.1 12 5 17 305 -11.5 0 -11.1 -11.9 12/02/2005 03:20:00 17.7 1.8 21.8 11.5 17.6 1.9 21.8 12.2 13 5 15 305 -11.6 0 -11.3 -11.9 12/02/2005 03:30:00 18.9 2.1 23.3 13.3 18.8 2.1 23.3 13.3 13 6 18 305 -11.4 0.1 -10.9 -11.7 12/02/2005 03:40:00 17.3 1.5 21 13 17.2 1.6 21 13 14 5 9 305 -11.6 0 -11.3 -11.9 12/02/2005 03:50:00 17.9 1.7 21.4 13.3 17.9 1.7 21.4 13.3 12 7 0 305 -11.5 0 -11.1 -11.7 12/02/2005 04:00:00 18.3 2 23.3 12.6 18.1 1.9 22.9 13.3 14 6 18 305 -11.6 0 -11.3 -11.9 12/02/2005 04:10:00 18.3 1.5 22.6 14.1 18.2 1.7 22.9 13 12 5 8 305 -11.6 0 -11.3 -11.9 12/02/2005 04:20:00 18 1.5 21.4 13.3 17.9 1.6 21.8 13.3 12 5 12 305 -11.5 0 -11.3 -11.9 12/02/2005 04:30:00 17.9 1.4 22.9 13.3 17.7 1.4 21.8 13.3 14 6 22 305 -11.5 0 -10.9 -11.7 12/02/2005 04:40:00 18.9 1.7 22.6 14.1 18.9 1.7 22.9 14.5 11 5 11 305 -11.4 0.1 -10.9 -11.9 12/02/2005 04:50:00 18.8 1.8 23.3 14.1 18.8 1.8 22.9 13.3 10 6 15 305 -11.7 0.1 -11.3 -12.1 12/02/2005 05:00:00 19.6 1.5 23.3 15.6 19.5 1.7 23.3 14.5 12 5 8 305 -11.9 0.1 -11.5 -12.1 12/02/2005 05:10:00 17.6 1.8 21.8 13.3 17.5 1.8 21.8 13 11 5 16 305 -11.7 0 -11.3 -11.9 12/02/2005 05:20:00 18.7 1.7 23.7 13.7 18.6 1.8 23.7 13.7 8 5 357 305 -11.9 0.1 -11.5 -12.1 12/02/2005 05:30:00 18.9 1.7 22.1 13.7 18.6 1.9 22.6 13 13 6 14 305 -12 0 -11.7 -12.3 12/02/2005 05:40:00 18.5 1.9 22.9 13.7 18.4 2 23.3 13.7 15 6 18 305 -12.1 0 -11.7 -12.5 12/02/2005 05:50:00 18.6 1.7 22.1 13.3 18.4 1.7 22.1 13.3 21 6 19 305 -12.2 0 -11.9 -12.5 12/02/2005 06:00:00 18.8 1.6 22.9 14.9 18.5 1.6 22.9 14.1 21 6 23 305 -12.2 0 -12.1 -12.5 12/02/2005 06:10:00 18.8 2.2 22.9 13.3 18.8 2.2 22.9 12.6 13 6 18 305 -12.4 0.1 -12.1 -12.7 12/02/2005 06:20:00 17.6 1.7 21.8 13 17.4 1.7 21.4 12.6 17 7 12 305 -12.4 0.1 -12.1 -12.5 12/02/2005 06:30:00 17.4 1.6 20.6 12.6 17.2 1.5 20.6 13 22 6 19 305 -12.6 0 -12.3 -12.9 12/02/2005 06:40:00 17.9 1.6 22.6 14.5 17.6 1.7 22.6 14.1 23 6 25 305 -13 0.1 -12.5 -13.3 12/02/2005 06:50:00 18.1 1.6 21.4 13.3 17.9 1.6 21.4 13 21 4 25 305 -13.2 0 -12.9 -13.3 12/02/2005 07:00:00 17.4 1.7 21 12.6 17.2 1.6 20.6 12.2 18 5 24 305 -13.2 0 -12.9 -13.5 12/02/2005 07:10:00 17.9 1.4 21.4 14.5 17.9 1.5 21.4 14.1 14 6 18 305 -13.1 0.1 -12.9 -13.5 12/02/2005 07:20:00 18.1 1.4 21.8 13.3 17.9 1.5 21.4 13.7 16 5 19 305 -13.1 0 -12.9 -13.3 12/02/2005 07:30:00 17.7 1.6 20.6 12.2 17.5 1.7 21 11.8 11 5 13 305 -13.1 0 -12.9 -13.3 12/02/2005 07:40:00 17.9 1.7 21.8 13.3 17.7 1.8 21.8 13.3 11 5 9 305 -13.1 0 -12.9 -13.3 12/02/2005 07:50:00 17.9 1.5 21 14.1 17.6 1.5 21 13.7 18 5 15 305 -13 0.1 -12.7 -13.1 12/02/2005 08:00:00 17.9 1.6 21 14.1 17.7 1.7 21 13 20 5 18 305 -13 0.1 -12.5 -13.3 12/02/2005 08:10:00 17.1 1.7 20.6 12.6 16.9 1.7 20.6 12.2 20 5 23 305 -12.9 0 -12.5 -13.1 12/02/2005 08:20:00 18.2 1.6 22.1 14.5 18.1 1.5 21.8 14.5 21 6 19 305 -12.9 0.1 -12.5 -13.1 12/02/2005 08:30:00 17.9 1.5 21.4 13.3 17.7 1.6 21.4 13 18 5 27 305 -12.9 0 -12.7 -13.1 12/02/2005 08:40:00 17 1.5 20.2 13.3 16.9 1.3 20.2 12.2 19 6 20 305 -12.8 0 -12.5 -12.9 12/02/2005 08:50:00 17.6 1.6 21 13.7 17.4 1.6 21 13.7 18 5 22 305 -12.8 0 -12.5 -12.9 12/02/2005 09:00:00 17.5 1.5 19.9 13.3 17.1 1.6 19.9 13 24 4 22 305 -12.8 0 -12.5 -12.9 12/02/2005 09:10:00 17.7 1.3 20.6 14.1 17.5 1.4 21 13.3 22 5 31 305 -12.8 0 -12.5 -12.9 12/02/2005 09:20:00 17.4 1.3 20.2 13.3 17.3 1.4 20.2 12.6 21 5 24 305 -12.8 0 -12.5 -13.1 12/02/2005 09:30:00 17.4 1.3 20.6 13.7 17.1 1.4 20.6 13 23 5 21 305 -12.8 0 -12.5 -12.9 12/02/2005 09:40:00 17.3 1.3 20.2 13.3 17 1.4 20.6 13 21 5 21 305 -12.8 0 -12.5 -12.9 12/02/2005 09:50:00 17.6 1.7 21.4 13 17.3 1.8 21.4 13 20 5 18 305 -12.6 0 -12.5 -12.9 12/02/2005 10:00:00 18.1 1.5 21.4 13 17.9 1.5 20.6 13.7 18 4 22 305 -12.6 0 -12.5 -12.9 12/02/2005 10:10:00 17.8 1.7 21 13.3 17.6 1.7 21.4 13.3 21 5 23 305 -12.6 0 -12.3 -12.7 12/02/2005 10:20:00 17.2 1.9 20.6 12.6 16.9 2 20.6 12.2 18 4 13 305 -12.5 0 -12.1 -12.7 12/02/2005 10:30:00 17.2 1.3 19.9 13.3 17 1.5 20.2 13.3 21 5 25 305 -12.5 0 -12.1 -12.5 12/02/2005 10:40:00 17.3 1.5 21 12.6 17 1.5 21.4 12.2 21 5 16 305 -12.5 0 -12.1 -12.7 12/02/2005 10:50:00 17.5 1.7 21 13 17.3 1.9 21.4 12.6 18 6 17 305 -12.4 0.1 -12.1 -12.5 12/02/2005 11:00:00 17.8 1.5 20.6 13.3 17.6 1.7 20.6 13.3 17 5 19 305 -12.4 0.1 -12.1 -12.5 12/02/2005 11:10:00 19.6 1.2 22.1 16.1 19.3 1.3 22.1 15.3 20 4 18 305 -12.5 0.1 -12.1 -12.5 12/02/2005 11:20:00 18.4 1.9 22.1 13 18.1 1.9 22.6 12.6 22 5 18 305 -12.4 0.1 -12.1 -12.5 12/02/2005 11:30:00 17.6 2.1 21.8 13 17.2 1.9 21 12.2 25 5 25 305 -12.3 0.1 -12.1 -12.5 12/02/2005 11:40:00 17.3 1.7 21 13 17 2 20.6 12.6 22 5 25 305 -12.3 0.1 -12.1 -12.5 12/02/2005 11:50:00 17.8 1.7 21 13.3 17.5 1.7 21.4 12.2 21 6 19 305 -12.4 0.1 -12.1 -12.5 12/02/2005 12:00:00 18.6 1.6 22.1 14.5 18.3 1.6 21.8 14.5 18 5 16 305 -12.4 0.1 -12.1 -12.5 12/02/2005 12:10:00 17.9 1.7 21.8 13.7 17.7 1.7 21.8 13.3 22 5 22 305 -12.4 0.1 -12.1 -12.5 12/02/2005 12:20:00 17.5 1.5 21.4 13.7 17.3 1.6 20.6 12.2 25 6 22 305 -12.5 0.1 -12.1 -12.7 12/02/2005 12:30:00 17.9 1.5 21.4 13.7 17.5 1.6 21.8 13.7 25 5 21 305 -12.4 0.1 -12.1 -12.5 12/02/2005 12:40:00 18.8 1.5 22.1 14.5 18.4 1.5 21.4 14.9 21 6 28 305 -12.5 0 -12.3 -12.5 12/02/2005 12:50:00 19 1.7 22.1 14.1 18.8 1.7 22.1 13.7 22 5 20 305 -12.5 0 -12.1 -12.7 12/02/2005 13:00:00 18.7 1.9 22.1 13.7 18.3 1.9 22.1 13.7 20 5 19 305 -12.4 0.1 -12.1 -12.5 12/02/2005 13:10:00 19 2.1 23.7 13.7 18.6 2.3 23.3 12.6 22 5 18 305 -12.4 0.1 -12.1 -12.5 12/02/2005 13:20:00 18.9 1.6 22.1 14.1 18.5 1.7 22.6 14.5 25 5 29 305 -12.2 0 -11.9 -12.5 12/02/2005 13:30:00 17.7 1.7 21.8 13.3 17.5 1.8 21.8 12.6 26 6 31 305 -12 0 -11.7 -12.3 12/02/2005 13:40:00 18.3 1.8 22.9 13.3 18.1 1.8 21.8 13.3 22 7 28 305 -12 0 -11.7 -12.1 12/02/2005 13:50:00 18 1.7 22.6 13 17.8 1.8 21.8 12.6 22 6 21 305 -12 0 -11.5 -12.3 12/02/2005 14:00:00 17.8 2.3 22.1 12.2 17.5 2.3 21.8 12.6 18 6 22 305 -12.1 0 -11.7 -12.3 12/02/2005 14:10:00 17.1 1.7 22.1 13.3 16.9 1.7 21.4 12.2 22 5 28 305 -12.1 0 -11.7 -12.5 12/02/2005 14:20:00 17.9 1.9 22.1 12.2 17.7 2 22.1 12.6 21 5 23 305 -12.3 0.1 -11.9 -12.5 12/02/2005 14:30:00 17.8 1.9 22.1 11.5 17.5 1.9 21.8 11.8 25 6 27 305 -12.3 0 -12.1 -12.5 12/02/2005 14:40:00 17.7 1.8 21.4 12.6 17.3 1.7 21.4 13 32 5 33 305 -12.3 0.1 -11.9 -12.5 12/02/2005 14:50:00 16.3 1.8 20.2 11.5 16.1 1.7 20.2 11.8 36 6 32 305 -12.5 0 -12.1 -12.5 12/02/2005 15:00:00 16.9 1.6 21 12.2 16.7 1.5 20.6 11.8 34 6 26 305 -12.5 0.1 -12.1 -12.7 12/02/2005 15:10:00 15.9 1.8 20.2 10.7 15.7 1.7 19.5 11.5 29 6 32 305 -12.3 0.1 -12.1 -12.5 12/02/2005 15:20:00 16.8 1.5 19.9 12.2 16.5 1.6 19.9 11.5 29 6 30 305 -12.4 0.1 -12.1 -12.5 12/02/2005 15:30:00 16.9 1.5 20.6 13 16.5 1.5 20.6 12.2 28 6 23 305 -12.2 0.1 -11.7 -12.5 12/02/2005 15:40:00 16.9 1.5 20.6 12.6 16.7 1.5 20.2 13 24 5 13 305 -12.2 0 -11.9 -12.5 12/02/2005 15:50:00 17.3 1.7 21 12.6 16.9 1.7 21 13 25 5 26 305 -12.1 0.1 -11.7 -12.5 12/02/2005 16:00:00 18.1 1.4 20.6 13.7 17.8 1.5 21 13.7 26 4 22 305 -12.2 0.1 -11.9 -12.5 12/02/2005 16:10:00 17 1.7 20.2 13 16.6 1.6 20.2 12.6 27 5 18 305 -12 0 -11.7 -12.3 12/02/2005 16:20:00 16.9 1.8 21.4 12.6 16.6 1.8 21 12.6 25 6 28 305 -11.9 0.1 -11.5 -12.1 12/02/2005 16:30:00 16.3 1.4 19.9 12.2 16 1.4 19.9 12.2 31 5 32 305 -11.9 0.1 -11.5 -12.1 12/02/2005 16:40:00 16.2 1.2 19.1 12.6 16 1.2 18.7 12.6 21 8 28 305 -12 0.2 -11.7 -12.5 12/02/2005 16:50:00 15.7 1.5 18.7 11.5 15.6 1.5 19.1 11.5 14 5 10 305 -12.3 0.1 -11.9 -12.5 12/02/2005 17:00:00 15 1.2 18.3 11.1 14.9 1.2 17.6 11.5 14 5 15 305 -12.4 0.1 -12.1 -12.7 12/02/2005 17:10:00 14.8 1.3 17.2 10.3 14.7 1.3 17.6 10.7 9 6 12 305 -12.5 0 -12.1 -12.9 12/02/2005 17:20:00 14.4 1.3 17.2 10.7 14.3 1.3 17.2 10.7 9 5 11 305 -12.6 0 -12.5 -12.9 12/02/2005 17:30:00 15.4 1.4 17.9 10.7 15.3 1.5 17.9 10.7 7 5 4 305 -12.8 0.1 -12.5 -12.9 12/02/2005 17:40:00 13.2 1 15.6 10.3 13.4 1.1 16.1 10.3 4 5 6 305 -12.7 0 -12.5 -12.9 12/02/2005 17:50:00 13.8 1.3 17.6 10.7 13.9 1.3 17.6 9.9 3 5 4 305 -12.6 0 -12.3 -12.9 12/02/2005 18:00:00 13.7 1.3 16.4 10.3 13.7 1.3 16.8 9.9 7 5 12 305 -12.6 0 -12.3 -12.7 12/02/2005 18:10:00 13.6 1.3 16.4 9.5 13.6 1.3 16.1 9.5 7 5 1 305 -12.6 0 -12.3 -12.9 12/02/2005 18:20:00 13.6 1.7 16.8 9.1 13.6 1.6 16.8 9.1 9 5 9 305 -12.8 0 -12.5 -12.9 12/02/2005 18:30:00 13.1 1.3 16.4 9.1 13.1 1.3 16.4 9.5 8 5 8 305 -12.7 0 -12.5 -12.9 12/02/2005 18:40:00 12.8 1.4 16.1 9.9 12.7 1.4 16.4 9.5 8 6 4 305 -12.7 0 -12.5 -12.9 12/02/2005 18:50:00 12.1 1.4 15.6 7.6 12.1 1.5 16.1 7.2 7 5 10 305 -12.6 0 -12.3 -12.9 12/02/2005 19:00:00 12.7 1 14.9 9.9 12.8 1.1 14.9 9.9 3 5 2 305 -12.7 0 -12.5 -12.9 12/02/2005 19:10:00 12 1.2 14.5 8 12.1 1.2 14.5 8.4 1 5 3 305 -12.6 0 -12.5 -12.9 12/02/2005 19:20:00 12.1 1.3 14.9 8.8 12.2 1.5 15.3 9.1 6 6 9 305 -12.5 0 -12.1 -12.9 12/02/2005 19:30:00 11.8 1.2 14.5 8.4 11.7 1.4 14.9 8 8 5 4 305 -12.5 0 -12.1 -12.5 12/02/2005 19:40:00 11.8 1.4 14.5 8 12 1.2 14.9 7.6 2 6 0 305 -12.6 0 -12.3 -12.7 12/02/2005 19:50:00 12.7 1.1 15.6 9.1 12.7 1.1 16.1 9.5 2 5 0 305 -12.6 0 -12.5 -12.9 12/02/2005 20:00:00 12.2 1.1 15.3 9.1 12.3 1.1 14.9 9.5 3 6 13 305 -12.6 0 -12.5 -12.9 12/02/2005 20:10:00 12.4 1 14.9 9.1 12.4 1.1 14.5 8.8 5 4 4 305 -12.7 0 -12.5 -12.9 12/02/2005 20:20:00 11.7 1.1 14.5 9.1 11.6 1.1 14.5 8.8 5 5 4 305 -12.6 0 -12.3 -12.7 12/02/2005 20:30:00 11.7 1 14.5 9.1 11.9 1 14.5 9.5 2 5 0 305 -12.7 0 -12.5 -12.9 12/02/2005 20:40:00 11.3 1.2 13.3 8.4 11.4 1.3 14.1 8.4 359 5 0 305 -12.6 0 -12.5 -12.9 12/02/2005 20:50:00 11.1 1.2 14.1 7.2 11.2 1.1 13.7 7.6 2 5 0 305 -12.6 0 -12.3 -12.7 12/02/2005 21:00:00 11.2 1.1 13.7 8.4 11.3 1.1 13.7 8.8 5 6 6 305 -12.5 0 -12.1 -12.7 12/02/2005 21:10:00 11.2 1.2 13.7 7.6 11.2 1.3 14.5 7.6 9 6 7 305 -12.5 0 -12.1 -12.7 12/02/2005 21:20:00 10.2 1 12.6 7.2 10.3 1 12.6 8 7 7 4 305 -12.4 0.1 -12.1 -12.5 12/02/2005 21:30:00 10 1 12.2 7.2 10.1 1 12.6 7.2 9 8 9 305 -12.3 0.1 -12.1 -12.5 12/02/2005 21:40:00 10.7 1.4 14.1 7.6 10.8 1.5 14.5 7.6 9 6 6 305 -12.3 0.1 -12.1 -12.5 12/02/2005 21:50:00 9.5 1 12.2 6.5 9.6 1.1 12.2 6.5 6 7 11 305 -12.3 0.1 -12.1 -12.5 12/02/2005 22:00:00 10.5 1.2 13 7.6 10.6 1.2 13.3 8 7 8 7 305 -12.3 0 -12.1 -12.5 12/02/2005 22:10:00 10.6 1.1 13.7 8 10.6 1.1 13.7 8.4 9 5 13 305 -12.2 0 -11.9 -12.5 12/02/2005 22:20:00 9.3 1.1 12.6 6.1 9.2 1 12.2 6.5 11 8 15 305 -12.1 0 -11.7 -12.3 12/02/2005 22:30:00 10.1 0.9 12.6 7.6 10 0.9 13 8 6 6 8 305 -11.9 0 -11.7 -12.1 12/02/2005 22:40:00 9.4 1 12.2 6.8 9.5 1.1 11.8 6.8 10 7 12 305 -11.9 0.1 -11.5 -12.1 12/02/2005 22:50:00 9.4 1.1 11.8 6.5 9.3 1.2 12.2 6.1 9 7 4 305 -11.8 0 -11.5 -12.1 12/02/2005 23:00:00 9 1.1 11.8 6.5 9 1.1 12.2 6.5 10 6 3 305 -11.6 0 -11.3 -11.9 12/02/2005 23:10:00 9.5 0.9 11.8 7.2 9.5 0.9 11.8 6.8 5 6 356 305 -11.5 0 -11.3 -11.7 12/02/2005 23:20:00 10.2 0.8 12.2 8 10.3 1 12.6 7.6 2 4 4 305 -11.5 0 -11.1 -11.7 12/02/2005 23:30:00 9.4 1.2 12.6 6.1 9.4 1.2 13 6.5 1 7 2 305 -11.4 0.1 -10.9 -11.5 12/02/2005 23:40:00 9.5 1 11.8 7.2 9.5 1.1 12.2 6.8 3 6 0 305 -11.3 0.1 -10.9 -11.5 12/02/2005 23:50:00 9.8 1 11.8 6.8 9.8 1 12.6 6.8 2 7 6 305 -11.3 0.1 -10.9 -11.5 12/03/2005 00:00:00 9.6 1.1 11.8 6.8 9.7 1.1 12.6 6.8 2 6 8 305 -11.3 0.1 -10.9 -11.5 12/03/2005 00:10:00 9.8 1 11.8 6.8 9.8 1 12.2 7.2 358 6 347 305 -11.2 0.1 -10.9 -11.5 12/03/2005 00:20:00 9.6 1 11.8 7.2 9.6 1.1 12.2 6.5 0 6 3 305 -11.3 0.1 -10.9 -11.5 12/03/2005 00:30:00 9.5 1.5 12.6 5.7 9.6 1.5 12.6 6.1 357 5 357 305 -11.2 0 -10.9 -11.5 12/03/2005 00:40:00 9.4 1 11.8 6.5 9.6 1.1 11.8 6.8 357 6 356 305 -11.2 0.1 -10.9 -11.5 12/03/2005 00:50:00 10.2 0.9 12.2 7.2 10.3 0.9 12.6 8 358 5 0 305 -11.2 0.1 -10.9 -11.5 12/03/2005 01:00:00 9.4 0.9 11.5 6.8 9.4 1 11.5 7.2 0 6 359 305 -11.2 0.1 -10.9 -11.5 12/03/2005 01:10:00 8.8 0.8 10.7 6.5 8.8 0.9 11.1 6.1 2 5 358 305 -11.2 0 -10.9 -11.3 12/03/2005 01:20:00 9 0.9 11.1 6.5 9 0.9 11.1 6.8 4 5 3 305 -11.2 0.1 -10.9 -11.5 12/03/2005 01:30:00 9.5 1 11.1 6.8 9.5 1 11.8 7.2 1 6 7 305 -11.2 0.1 -10.9 -11.5 12/03/2005 01:40:00 9.1 1.1 11.8 5.7 9.2 1.1 12.2 6.5 0 6 7 305 -11.1 0.1 -10.7 -11.3 12/03/2005 01:50:00 9.1 0.9 11.1 6.8 9.1 0.9 11.5 7.2 358 5 354 305 -11 0 -10.7 -11.3 12/03/2005 02:00:00 9.9 1.1 12.2 7.2 9.9 1.2 13 7.2 1 7 2 305 -11 0 -10.4 -11.3 12/03/2005 02:10:00 8.9 1.2 11.8 6.1 8.9 1.2 12.2 6.5 16 11 22 305 -11 0 -10.4 -11.3 12/03/2005 02:20:00 10.5 0.8 12.2 8.4 10.5 0.9 12.2 8 25 4 25 305 -11 0 -10.7 -11.3 12/03/2005 02:30:00 9.9 1 12.2 7.2 9.8 1 12.2 6.8 26 6 21 305 -11 0 -10.9 -11.3 12/03/2005 02:40:00 9.1 0.8 11.1 6.1 9 0.9 11.5 6.5 18 7 26 305 -11.1 0 -10.9 -11.3 12/03/2005 02:50:00 8.9 0.8 11.1 6.8 8.8 0.8 11.1 7.2 20 6 23 305 -11.1 0 -10.9 -11.3 12/03/2005 03:00:00 9.3 0.9 11.8 6.8 9.2 1 11.5 6.8 19 7 22 305 -11 0 -10.7 -11.3 12/03/2005 03:10:00 8.8 0.7 11.1 6.5 8.8 0.7 11.8 6.8 22 4 21 305 -11.1 0 -10.9 -11.3 12/03/2005 03:20:00 8.9 0.8 10.7 6.1 8.8 0.7 10.3 6.5 23 6 10 305 -11.1 0 -10.9 -11.3 12/03/2005 03:30:00 9 0.7 10.7 7.2 8.8 0.8 11.1 6.8 28 5 22 305 -11.2 0 -10.9 -11.5 12/03/2005 03:40:00 8.8 0.7 10.3 6.8 8.8 0.7 10.3 6.8 25 4 26 305 -11.3 0 -10.9 -11.5 12/03/2005 03:50:00 8.5 0.9 11.5 6.1 8.5 1 11.8 6.1 21 6 23 305 -11.2 0 -10.9 -11.5 12/03/2005 04:00:00 9.5 1 11.8 6.8 9.5 1 12.2 7.2 23 5 29 305 -11.2 0.1 -10.7 -11.5 12/03/2005 04:10:00 9.2 0.7 10.7 7.2 9.2 0.8 11.1 6.8 21 5 15 305 -11.3 0 -11.3 -11.5 12/03/2005 04:20:00 9.6 0.7 11.5 7.6 9.5 0.7 11.1 7.6 20 5 22 305 -11.5 0 -11.3 -11.7 12/03/2005 04:30:00 9.3 1 11.5 6.5 9.1 1 11.1 6.5 18 7 14 305 -11.5 0 -11.1 -11.7 12/03/2005 04:40:00 9.2 0.8 11.5 7.6 9.2 0.8 11.5 7.2 16 5 22 305 -11.3 0.1 -10.9 -11.5 12/03/2005 04:50:00 8.9 1 11.8 6.8 8.9 1.1 12.2 6.5 14 5 12 305 -11.2 0 -10.9 -11.3 12/03/2005 05:00:00 8.8 1.2 11.5 5.7 8.7 1.2 11.5 5.7 13 7 15 305 -11.1 0 -10.9 -11.3 12/03/2005 05:10:00 8.4 1 11.1 6.5 8.4 1 11.1 6.1 16 6 22 305 -11 0 -10.7 -11.3 12/03/2005 05:20:00 9.1 1 10.7 6.1 9.1 1 11.1 6.5 20 4 21 305 -11 0 -10.4 -11.3 12/03/2005 05:30:00 9.3 0.9 11.1 6.8 9.2 0.9 11.1 6.5 18 4 18 305 -11.2 0 -10.9 -11.3 12/03/2005 05:40:00 8.5 0.6 9.9 6.5 8.5 0.7 9.9 6.1 16 3 18 305 -11.2 0 -10.9 -11.3 12/03/2005 05:50:00 8.8 0.6 10.3 7.2 8.8 0.7 10.7 6.5 15 4 12 305 -11.2 0 -10.9 -11.3 12/03/2005 06:00:00 8 0.8 10.3 5.7 8 0.8 9.9 6.1 17 5 18 305 -11.2 0 -10.9 -11.3 12/03/2005 06:10:00 7.1 0.8 8.8 4.9 7.1 0.8 8.8 4.9 15 5 17 305 -11.1 0 -10.7 -11.3 12/03/2005 06:20:00 7.6 0.8 9.5 5.3 7.6 0.8 9.9 5.7 11 5 8 305 -11 0 -10.4 -11.3 12/03/2005 06:30:00 8.2 0.6 9.5 6.1 8.2 0.6 9.9 6.5 21 13 14 305 -11 0 -10.7 -11.3 12/03/2005 06:40:00 8.7 0.8 11.1 6.5 8.6 0.8 11.1 6.5 30 5 37 305 -11.3 0.1 -10.9 -11.5 12/03/2005 06:50:00 8.9 0.8 10.7 7.2 8.9 0.8 10.7 6.5 28 5 31 305 -11.3 0.1 -10.9 -11.5 12/03/2005 07:00:00 8.6 0.8 10.3 6.8 8.5 0.9 9.9 6.1 30 5 26 305 -11.4 0.1 -10.9 -11.7 12/03/2005 07:10:00 8.5 0.6 9.9 6.8 8.5 0.7 9.9 6.5 32 4 36 305 -11.5 0 -11.1 -11.7 12/03/2005 07:20:00 8 0.9 10.7 5.3 8 0.9 11.1 5.3 30 6 29 305 -11.5 0 -11.3 -11.7 12/03/2005 07:30:00 6.9 0.7 8.8 5.3 6.9 0.7 8.8 4.9 29 7 35 305 -11.5 0 -11.3 -11.7 12/03/2005 07:40:00 7.3 0.5 8.8 5.3 7.2 0.6 8.8 5.7 33 5 28 305 -11.6 0 -11.3 -11.7 12/03/2005 07:50:00 7.5 0.8 9.1 5.3 7.6 0.8 9.1 5.7 41 6 39 305 -11.7 0.1 -11.3 -12.1 12/03/2005 08:00:00 8.1 0.7 9.5 5.7 8.1 0.7 9.1 6.1 38 6 45 305 -11.9 0 -11.7 -12.1 12/03/2005 08:10:00 7.6 0.9 9.5 4.9 7.6 0.9 9.5 5.3 29 9 18 305 -11.9 0 -11.5 -12.1 12/03/2005 08:20:00 8.8 1 10.7 6.8 8.8 1 11.1 6.1 23 5 22 305 -11.9 0.1 -11.7 -12.1 12/03/2005 08:30:00 9.1 0.9 11.1 6.1 9.1 0.9 11.1 6.5 23 5 18 305 -11.9 0.1 -11.5 -12.1 12/03/2005 08:40:00 9.6 0.8 11.5 7.6 9.5 0.8 11.5 7.6 24 5 23 305 -12 0 -11.7 -12.3 12/03/2005 08:50:00 8.8 0.8 10.7 6.5 8.8 0.9 10.7 6.1 20 4 18 305 -12.1 0 -11.7 -12.3 12/03/2005 09:00:00 8.9 0.8 10.7 6.5 8.8 0.8 10.7 6.5 18 5 23 305 -12.1 0.1 -11.7 -12.3 12/03/2005 09:10:00 8.8 1 11.1 6.5 8.8 0.9 11.5 6.5 15 5 15 305 -11.9 0.1 -11.7 -12.1 12/03/2005 09:20:00 8.4 1 10.3 6.1 8.3 0.9 10.7 5.7 24 5 30 305 -12 0 -11.7 -12.3 12/03/2005 09:30:00 8.7 0.7 10.3 6.8 8.7 0.7 10.3 6.5 25 4 23 305 -12.2 0 -11.9 -12.3 12/03/2005 09:40:00 8.6 0.7 10.3 6.8 8.8 0.8 10.3 6.8 18 4 22 305 -12.2 0 -11.9 -12.3 12/03/2005 09:50:00 8.2 0.7 9.9 6.5 8.2 0.7 9.9 6.1 25 5 27 305 -12.3 0 -12.1 -12.5 12/03/2005 10:00:00 7.9 0.7 9.5 6.1 8 0.8 9.5 6.1 20 5 14 305 -12.2 0.1 -11.9 -12.5 12/03/2005 10:10:00 8.9 0.8 11.1 6.5 8.8 0.8 10.7 6.5 16 5 14 305 -12.2 0 -11.9 -12.5 12/03/2005 10:20:00 8.3 0.8 10.3 6.1 8.1 0.8 10.3 6.1 22 6 13 305 -12.1 0 -11.7 -12.5 12/03/2005 10:30:00 8.2 0.6 10.7 6.5 8.1 0.7 10.3 6.5 23 6 21 305 -12.2 0 -11.9 -12.5 12/03/2005 10:40:00 9 0.8 10.7 6.8 8.8 0.9 11.1 6.5 18 6 22 305 -12.2 0 -11.9 -12.5 12/03/2005 10:50:00 9.3 0.7 10.7 6.8 9.3 0.7 10.7 7.2 19 4 11 305 -12.2 0 -12.1 -12.5 12/03/2005 11:00:00 8.5 0.6 9.9 6.1 8.5 0.7 10.3 6.1 25 5 23 305 -12.3 0 -12.1 -12.5 12/03/2005 11:10:00 8.6 0.7 10.3 6.8 8.6 0.7 10.3 6.8 22 5 23 305 -12.3 0 -12.1 -12.5 12/03/2005 11:20:00 8.1 0.5 9.5 6.8 8.1 0.6 9.5 6.5 21 5 18 305 -12.2 0 -12.1 -12.5 12/03/2005 11:30:00 8.2 0.8 9.9 6.1 8.2 0.8 9.9 6.1 19 5 15 305 -12.1 0 -11.7 -12.3 12/03/2005 11:40:00 8.4 0.8 10.3 6.5 8.3 0.9 9.9 6.1 21 5 14 305 -12 0 -11.7 -12.1 12/03/2005 11:50:00 8.2 0.9 9.9 5.7 8.2 0.9 9.9 5.7 19 4 22 305 -11.9 0.1 -11.5 -12.1 12/03/2005 12:00:00 8.8 0.8 10.3 6.5 8.7 0.8 10.3 6.8 18 4 19 305 -11.9 0 -11.7 -12.1 12/03/2005 12:10:00 8.6 0.8 9.9 6.5 8.6 0.8 10.3 6.5 23 5 18 305 -11.9 0.1 -11.7 -12.1 12/03/2005 12:20:00 7.5 0.9 9.5 5.3 7.5 0.8 9.5 5.7 21 6 21 305 -11.9 0.1 -11.5 -12.1 12/03/2005 12:30:00 8.4 0.8 9.9 6.5 8.3 0.8 9.9 6.1 23 4 24 305 -11.9 0.1 -11.5 -12.1 12/03/2005 12:40:00 7.9 0.8 9.9 6.1 7.9 0.8 9.9 6.1 21 5 17 305 -11.9 0.1 -11.5 -12.1 12/03/2005 12:50:00 8.1 0.8 10.3 6.1 8.1 0.7 9.9 6.1 25 5 26 305 -11.9 0.1 -11.5 -12.1 12/03/2005 13:00:00 8.1 0.7 10.3 6.5 8.1 0.7 10.3 6.1 27 5 27 305 -11.8 0.1 -11.5 -12.1 12/03/2005 13:10:00 8.7 0.6 10.7 6.8 8.6 0.7 11.1 6.8 19 5 25 305 -11.8 0.1 -11.5 -12.1 12/03/2005 13:20:00 7.9 0.9 9.9 5.7 7.8 1 9.9 5.3 21 7 19 305 -11.7 0.1 -11.5 -11.9 12/03/2005 13:30:00 7.4 0.8 9.1 5.3 7.4 0.9 9.5 5.3 22 6 26 305 -11.8 0.1 -11.5 -12.1 12/03/2005 13:40:00 7.5 1 10.3 5.3 7.6 1 9.9 5.3 20 7 13 305 -11.7 0 -11.3 -11.9 12/03/2005 13:50:00 7.5 0.6 9.5 5.7 7.5 0.6 8.8 5.7 19 5 18 305 -11.6 0 -11.3 -11.7 12/03/2005 14:00:00 8.1 1 9.9 5.7 8.2 0.8 9.9 6.1 15 6 16 305 -11.5 0 -11.3 -11.7 12/03/2005 14:10:00 8.5 0.9 10.3 5.7 8.5 0.9 10.3 6.1 20 5 22 305 -11.7 0.1 -11.3 -11.9 12/03/2005 14:20:00 9.3 0.9 11.1 6.1 9.2 1 11.1 6.5 13 5 11 305 -11.7 0 -11.5 -11.9 12/03/2005 14:30:00 9 0.8 10.7 6.8 9 0.9 11.5 6.8 21 4 22 305 -11.7 0 -11.5 -11.9 12/03/2005 14:40:00 7.8 0.6 9.9 5.7 7.8 0.7 9.5 5.3 23 5 19 305 -11.8 0 -11.5 -12.1 12/03/2005 14:50:00 7.9 0.8 9.1 6.1 7.9 0.8 9.5 6.1 25 6 15 305 -11.9 0 -11.7 -12.1 12/03/2005 15:00:00 7.6 1 9.5 5.3 7.6 1 9.9 5.3 27 5 24 305 -11.9 0 -11.7 -12.1 12/03/2005 15:10:00 7.7 0.8 9.5 5.7 7.7 0.8 9.5 5.7 24 5 26 305 -11.9 0 -11.5 -12.1 12/03/2005 15:20:00 7.6 0.7 9.1 5.7 7.6 0.7 9.1 5.7 24 4 27 305 -12 0 -11.7 -12.1 12/03/2005 15:30:00 7 0.8 8.8 4.9 7 0.7 8.8 4.9 22 5 29 305 -12 0 -11.7 -12.1 12/03/2005 15:40:00 7.2 0.9 9.9 4.9 7.2 1 10.3 4.9 11 8 4 305 -12 0 -11.7 -12.1 12/03/2005 15:50:00 7.9 0.9 10.3 5.7 7.9 0.9 10.3 5.3 7 6 10 305 -12 0 -11.7 -12.3 12/03/2005 16:00:00 7.7 0.9 10.3 5.7 7.7 1 9.9 5.3 5 5 15 305 -12 0 -11.7 -12.3 12/03/2005 16:10:00 7 0.8 8.8 4.9 7 0.9 8.8 4.9 10 6 14 305 -12 0 -11.7 -12.3 12/03/2005 16:20:00 7.4 0.9 9.5 5.7 7.3 0.8 9.1 5.7 11 8 16 305 -12 0 -11.7 -12.1 12/03/2005 16:30:00 7.5 0.9 9.9 5.7 7.5 0.9 9.9 5.3 11 7 11 305 -12 0 -11.7 -12.3 12/03/2005 16:40:00 7.4 1 10.3 4.6 7.4 1 10.3 5.3 10 5 12 305 -12.1 0 -11.7 -12.3 12/03/2005 16:50:00 7.6 0.6 9.1 5.7 7.6 0.7 9.9 5.7 14 8 14 305 -12.1 0 -11.7 -12.3 12/03/2005 17:00:00 8.2 1 9.9 5.3 8.2 1 10.3 5.7 17 6 16 305 -12.1 0 -11.9 -12.3 12/03/2005 17:10:00 8.1 0.9 10.7 6.1 8.2 1 10.7 6.1 20 6 15 305 -12.2 0 -11.9 -12.5 12/03/2005 17:20:00 8.2 0.8 9.9 5.7 8.2 0.9 10.3 5.3 17 8 21 305 -12.2 0 -11.9 -12.5 12/03/2005 17:30:00 8.4 0.9 11.5 6.5 8.3 1 11.8 6.1 11 6 15 305 -12.3 0 -12.1 -12.5 12/03/2005 17:40:00 8 0.9 10.3 5.3 8 0.9 10.3 6.1 10 6 16 305 -12.3 0 -11.9 -12.5 12/03/2005 17:50:00 8.5 1 11.1 6.5 8.5 1 11.5 6.5 15 8 21 305 -12.4 0.1 -12.1 -12.5 12/03/2005 18:00:00 8.9 0.8 10.7 6.8 8.8 0.8 10.7 6.5 14 6 26 305 -12.4 0.1 -12.1 -12.5 12/03/2005 18:10:00 8.5 1.7 12.6 5.3 8.6 1.7 13 5.3 16 5 17 305 -12.5 0.1 -12.1 -12.7 12/03/2005 18:20:00 9.5 1.1 11.8 6.1 9.5 1.2 12.2 6.1 16 7 19 305 -12.5 0.1 -12.1 -12.5 12/03/2005 18:30:00 8.8 1.1 12.2 6.1 8.9 1.1 12.6 6.5 18 8 18 305 -12.5 0 -12.1 -12.5 12/03/2005 18:40:00 9 0.9 11.8 7.2 8.9 0.9 11.8 6.5 14 6 16 305 -12.4 0.1 -12.1 -12.5 12/03/2005 18:50:00 9.4 0.9 11.5 6.8 9.4 0.9 11.8 6.8 16 7 17 305 -12.4 0.1 -12.1 -12.5 12/03/2005 19:00:00 8.8 0.8 10.7 6.5 8.7 0.8 11.1 6.1 18 8 13 305 -12.5 0 -12.1 -12.5 12/03/2005 19:10:00 9.3 1.1 12.2 6.8 9.3 1.2 12.2 6.1 18 8 20 305 -12.5 0 -12.3 -12.7 12/03/2005 19:20:00 9 1 11.1 6.5 9 1 11.1 6.5 16 7 9 305 -12.5 0 -12.1 -12.7 12/03/2005 19:30:00 8.8 0.8 10.7 6.5 8.9 1 11.1 6.5 19 12 13 305 -12.4 0 -12.1 -12.5 12/03/2005 19:40:00 7.6 1 10.3 4.2 7.6 1 10.7 4.9 28 5 30 305 -12.5 0 -12.1 -12.5 12/03/2005 19:50:00 8.6 0.9 11.1 6.1 8.6 0.9 11.1 6.1 20 6 18 305 -12.5 0 -12.1 -12.7 12/03/2005 20:00:00 7.9 1.2 10.7 5.3 8.1 1.2 11.1 5.7 8 6 4 305 -12.7 0 -12.3 -12.9 12/03/2005 20:10:00 9.2 1.5 11.5 5.7 9.1 1.5 11.8 5.7 23 7 27 305 -12.8 0.1 -12.5 -12.9 12/03/2005 20:20:00 9.2 1.1 11.8 6.8 9.3 1 11.8 7.2 21 6 24 305 -13 0.1 -12.7 -13.1 12/03/2005 20:30:00 8.1 0.9 11.1 6.1 8.1 0.8 10.7 5.7 35 10 16 305 -13 0 -12.7 -13.3 12/03/2005 20:40:00 7.3 1.1 10.3 4.9 7.3 1.1 10.7 4.6 30 7 17 305 -12.9 0 -12.5 -13.1 12/03/2005 20:50:00 7.2 0.9 9.9 4.9 7.2 1 10.3 5.3 38 8 29 305 -12.7 0 -12.5 -12.9 12/03/2005 21:00:00 7.8 0.8 9.9 5.3 7.7 0.9 9.9 4.6 38 8 33 305 -12.6 0 -12.1 -12.9 12/03/2005 21:10:00 7.9 1 9.9 5.7 7.8 0.9 10.3 5.7 30 6 32 305 -12.5 0 -12.1 -12.5 12/03/2005 21:20:00 7.3 0.8 9.1 5.3 7.4 0.8 9.5 5.3 31 7 24 305 -12.2 0.1 -11.7 -12.5 12/03/2005 21:30:00 7 0.9 8.8 4.9 6.9 0.9 9.1 4.9 34 7 46 305 -12 0 -11.7 -12.1 12/03/2005 21:40:00 6.9 0.9 8.8 4.6 7 0.9 9.1 4.9 29 7 29 305 -11.9 0.1 -11.5 -12.1 12/03/2005 21:50:00 8.1 1.1 10.7 4.9 8.1 1.1 10.3 4.6 25 6 28 305 -11.7 0 -11.3 -12.1 12/03/2005 22:00:00 7.8 1 9.9 5.3 7.7 1.1 10.3 5.3 31 8 29 305 -11.7 0 -11.3 -11.9 12/03/2005 22:10:00 8.5 0.8 11.1 5.7 8.4 1 11.5 5.3 26 6 35 305 -11.7 0 -11.3 -11.9 12/03/2005 22:20:00 8.1 1 11.1 5.7 8.1 1 10.3 5.3 24 7 18 305 -11.7 0 -11.3 -11.9 12/03/2005 22:30:00 8.2 0.9 10.3 5.7 8.1 0.9 10.3 5.7 24 6 22 305 -11.7 0.1 -11.3 -11.9 12/03/2005 22:40:00 8.9 0.7 10.7 7.2 8.9 0.7 10.7 6.8 19 4 25 305 -11.8 0.1 -11.5 -12.1 12/03/2005 22:50:00 8.9 0.8 10.7 6.8 9 0.8 10.7 6.8 23 6 18 305 -11.8 0.1 -11.5 -12.1 12/03/2005 23:00:00 7.3 0.9 9.1 5.3 7.2 1 9.5 5.3 23 7 27 305 -11.8 0 -11.5 -12.1 12/03/2005 23:10:00 8.6 0.8 10.7 6.5 8.6 0.9 10.3 6.1 22 4 15 305 -11.8 0.1 -11.5 -12.1 12/03/2005 23:20:00 8.4 0.8 9.9 6.1 8.4 0.9 10.3 6.1 20 6 9 305 -11.9 0 -11.5 -12.1 12/03/2005 23:30:00 8.2 0.8 9.9 6.1 8.2 0.8 9.9 6.1 23 5 21 305 -11.9 0 -11.7 -12.1 12/03/2005 23:40:00 8.4 0.9 10.3 6.1 8.3 1 10.3 6.1 20 5 20 305 -11.9 0 -11.7 -12.1 12/03/2005 23:50:00 9 0.7 11.1 6.8 8.9 0.7 11.1 6.8 21 6 11 305 -12 0 -11.7 -12.1 12/04/2005 00:00:00 8.4 0.9 10.7 6.1 8.3 0.9 10.7 6.1 24 6 20 305 -11.9 0.1 -11.7 -12.1 12/04/2005 00:10:00 9.2 0.8 10.7 6.8 9.1 0.8 11.1 7.2 18 4 21 305 -12 0 -11.7 -12.3 12/04/2005 00:20:00 8.9 0.8 11.1 6.8 8.9 0.8 10.7 6.5 21 6 14 305 -12 0 -11.7 -12.1 12/04/2005 00:30:00 8.5 0.7 10.3 6.8 8.4 0.8 10.3 6.5 20 5 24 305 -12 0 -11.7 -12.1 12/04/2005 00:40:00 9.3 0.9 11.5 6.8 9.2 1 11.1 6.5 22 6 23 305 -12.1 0 -11.7 -12.3 12/04/2005 00:50:00 9.1 0.9 11.5 6.8 9 0.9 11.8 6.8 21 7 24 305 -12.1 0.1 -11.7 -12.3 12/04/2005 01:00:00 9.5 1 11.5 7.2 9.5 1 11.8 7.2 25 5 23 305 -12.2 0.1 -11.7 -12.5 12/04/2005 01:10:00 8.2 1 10.3 5.7 8.2 1 10.3 6.1 21 6 27 305 -12.3 0.1 -12.1 -12.5 12/04/2005 01:20:00 8 0.7 9.5 6.1 8 0.7 9.9 6.1 32 9 46 305 -12.3 0.1 -12.1 -12.5 12/04/2005 01:30:00 8.2 0.9 9.9 6.1 8.2 0.8 9.9 6.1 34 7 36 305 -12.3 0 -12.1 -12.5 12/04/2005 01:40:00 7.4 1.2 9.9 4.6 7.5 1.2 9.9 4.6 42 7 51 305 -12.3 0.1 -11.9 -12.5 12/04/2005 01:50:00 8 0.8 10.3 5.7 8 0.9 10.3 6.1 34 7 35 305 -12.4 0.1 -12.1 -12.5 12/04/2005 02:00:00 7.7 0.8 9.9 5.7 7.7 0.9 9.9 5.7 36 5 32 305 -12.4 0.1 -12.1 -12.5 12/04/2005 02:10:00 7 1.1 10.3 4.6 7 1.2 10.7 4.9 49 8 49 305 -12.4 0.1 -12.1 -12.5 12/04/2005 02:20:00 7.7 0.8 9.9 5.7 7.6 0.9 10.3 5.7 30 7 27 305 -12.3 0 -12.1 -12.5 12/04/2005 02:30:00 7.1 0.7 8.8 5.3 7.2 0.7 8.8 4.9 42 7 35 305 -12.3 0 -12.1 -12.5 12/04/2005 02:40:00 8.4 0.8 9.9 5.7 8.4 0.9 9.9 5.7 29 5 20 305 -12.3 0 -12.1 -12.5 12/04/2005 02:50:00 8 0.8 10.3 6.1 8 0.8 10.3 6.1 27 6 34 305 -12.4 0.1 -12.1 -12.5 12/04/2005 03:00:00 8.6 0.9 10.7 6.1 8.6 0.9 11.1 6.5 26 5 39 305 -12.4 0.1 -11.9 -12.5 12/04/2005 03:10:00 8.4 0.8 10.7 6.5 8.4 0.8 9.9 6.5 28 7 36 305 -12.2 0.1 -11.9 -12.5 12/04/2005 03:20:00 8.7 0.7 10.7 6.5 8.7 0.8 10.3 6.5 26 6 26 305 -12.3 0.1 -12.1 -12.5 12/04/2005 03:30:00 8.8 0.7 10.3 6.5 8.7 0.8 10.3 6.1 29 6 31 305 -12.3 0 -12.1 -12.5 12/04/2005 03:40:00 8.7 1 10.7 6.1 8.6 1 10.7 6.1 21 7 22 305 -12.4 0.1 -12.1 -12.5 12/04/2005 03:50:00 8.5 0.8 11.1 6.5 8.6 0.8 11.1 6.5 33 6 32 305 -12.3 0 -12.1 -12.5 12/04/2005 04:00:00 8.3 0.8 10.3 6.5 8.3 0.9 10.3 6.5 37 6 25 305 -12.3 0.1 -12.1 -12.5 12/04/2005 04:10:00 8.7 1 11.5 6.1 8.7 1 11.1 6.1 41 6 48 305 -12.3 0.1 -12.1 -12.5 12/04/2005 04:20:00 7.9 0.9 9.9 5.7 7.9 0.9 9.9 5.3 37 8 39 305 -12.4 0.1 -12.1 -12.5 12/04/2005 04:30:00 7.7 0.6 9.1 6.5 7.7 0.6 9.1 6.1 50 10 52 305 -12.3 0.1 -12.1 -12.5 12/04/2005 04:40:00 7.4 1 9.9 5.3 7.2 1 10.3 5.3 62 11 61 305 -12.3 0.1 -11.9 -12.5 12/04/2005 04:50:00 8.1 0.9 9.9 6.1 8.1 1 10.3 6.1 48 9 48 305 -12.3 0.1 -11.9 -12.5 12/04/2005 05:00:00 7.7 0.8 9.9 5.7 7.7 0.9 9.9 5.7 38 7 44 305 -12.2 0 -11.9 -12.3 12/04/2005 05:10:00 7.1 1.1 9.9 4.9 7 1.1 10.3 4.9 42 6 39 305 -12.3 0 -12.1 -12.5 12/04/2005 05:20:00 6.5 1 8.8 4.2 6.5 0.9 8.8 4.9 43 8 32 305 -12.1 0 -11.9 -12.5 12/04/2005 05:30:00 7.1 0.7 8.4 5.3 7.1 0.8 9.1 4.9 52 7 50 305 -12.1 0 -11.9 -12.3 12/04/2005 05:40:00 7.2 0.9 9.1 4.9 7.3 0.9 9.9 4.9 51 9 55 305 -12.1 0 -11.7 -12.3 12/04/2005 05:50:00 6.8 0.9 9.9 4.2 6.5 1 9.1 4.2 71 6 70 305 -12.2 0.1 -11.7 -12.5 12/04/2005 06:00:00 6.8 0.8 8.8 4.9 6.5 0.8 8 4.9 76 5 78 305 -12.3 0.1 -12.1 -12.5 12/04/2005 06:10:00 7.7 1 9.5 5.3 7.3 1.1 9.5 4.2 69 8 67 305 -12.4 0.1 -12.1 -12.5 12/04/2005 06:20:00 8 0.7 9.5 6.1 8 0.7 9.5 5.7 42 7 36 305 -12.3 0.1 -12.1 -12.5 12/04/2005 06:30:00 7.3 1.2 9.9 4.9 7.4 1.2 10.3 4.9 40 6 37 305 -12.4 0.1 -12.1 -12.5 12/04/2005 06:40:00 8.2 0.7 9.9 6.8 8.2 0.7 9.9 6.5 40 5 35 305 -12.3 0.1 -12.1 -12.5 12/04/2005 06:50:00 8.4 0.9 10.3 6.5 8.5 0.9 10.7 6.5 48 6 45 305 -12.4 0.1 -12.1 -12.5 12/04/2005 07:00:00 7.6 0.8 9.9 5.3 7.5 1 9.9 5.3 54 10 55 305 -12.4 0.1 -12.1 -12.5 12/04/2005 07:10:00 7.5 1 10.7 4.9 7.5 1 10.3 4.9 56 7 50 305 -12.2 0 -11.9 -12.5 12/04/2005 07:20:00 7.4 1 10.3 4.6 7.4 1 9.9 4.6 42 7 32 305 -12.1 0 -11.7 -12.3 12/04/2005 07:30:00 7.5 1.1 11.1 5.3 7.5 1.3 10.3 5.3 35 6 28 305 -12.1 0.1 -11.7 -12.3 12/04/2005 07:40:00 7.4 1 10.3 4.9 7.3 1 10.7 4.6 32 7 44 305 -12 0.1 -11.7 -12.3 12/04/2005 07:50:00 7 1.1 10.7 4.6 7 1.2 10.7 4.2 51 9 53 305 -12 0 -11.7 -12.3 12/04/2005 08:00:00 6.9 1.1 9.9 4.6 6.9 1 9.5 4.6 49 9 48 305 -12.1 0 -11.7 -12.5 12/04/2005 08:10:00 6.2 0.8 8.8 4.6 5.9 0.8 8.4 4.2 72 13 58 305 -12.2 0.1 -11.7 -12.5 12/04/2005 08:20:00 5.8 0.8 8 3.8 5.4 0.7 7.6 3.8 76 7 81 305 -12.4 0.1 -12.1 -12.5 12/04/2005 08:30:00 6.6 0.7 8.4 4.9 6.5 0.7 8.8 4.6 63 8 67 305 -12.3 0 -11.9 -12.5 12/04/2005 08:40:00 7.2 1 10.3 4.9 7.2 1.1 11.1 4.9 52 10 54 305 -12 0 -11.7 -12.3 12/04/2005 08:50:00 7.5 1.5 11.1 4.9 7.5 1.7 11.5 4.6 49 9 48 305 -12 0 -11.7 -12.3 12/04/2005 09:00:00 8.4 0.9 11.1 6.5 8.4 1 11.5 6.1 42 7 46 305 -12 0 -11.7 -12.3 12/04/2005 09:10:00 8.5 0.7 10.3 6.5 8.5 0.7 10.3 6.5 40 6 40 305 -12.1 0 -11.7 -12.3 12/04/2005 09:20:00 7.7 1.1 9.9 5.7 7.6 1.3 10.3 4.9 64 10 52 305 -12.1 0 -11.9 -12.3 12/04/2005 09:30:00 6 0.8 9.1 3.8 5.9 0.8 8 3.8 60 12 34 305 -12.2 0 -11.7 -12.5 12/04/2005 09:40:00 6.7 1.2 9.9 4.6 6.5 1.3 10.3 4.2 63 9 62 305 -12.1 0 -11.7 -12.3 12/04/2005 09:50:00 6.6 0.6 8 4.9 6.3 0.6 7.6 4.9 75 9 76 305 -12.1 0 -11.7 -12.3 12/04/2005 10:00:00 6.9 0.9 9.1 4.6 6.4 0.9 9.1 4.2 75 7 73 305 -12.1 0 -11.7 -12.3 12/04/2005 10:10:00 8 1 10.7 6.1 7.7 0.9 10.7 5.7 66 8 70 305 -12.1 0 -11.7 -12.3 12/04/2005 10:20:00 7.7 0.8 9.5 6.1 7.3 0.8 9.5 5.3 73 4 70 305 -12.2 0 -11.9 -12.5 12/04/2005 10:30:00 7.5 0.9 10.3 5.3 7.3 0.9 9.9 5.3 63 9 62 305 -12.3 0 -11.9 -12.5 12/04/2005 10:40:00 8.4 1.3 11.1 4.9 8.3 1.3 10.7 4.9 54 9 57 305 -12.3 0 -11.9 -12.5 12/04/2005 10:50:00 8.8 0.9 11.5 6.8 8.9 0.9 12.2 6.8 52 7 48 305 -12.3 0.1 -11.9 -12.5 12/04/2005 11:00:00 8.3 0.8 10.7 6.5 8.2 0.8 11.1 6.1 57 7 55 305 -12.3 0.1 -12.1 -12.5 12/04/2005 11:10:00 8 0.9 10.3 6.1 7.9 1 10.3 5.7 56 9 52 305 -12.3 0.1 -11.9 -12.5 12/04/2005 11:20:00 7.2 1.1 10.3 4.9 7.2 1.1 10.3 4.6 57 11 48 305 -12.2 0.1 -11.9 -12.5 12/04/2005 11:30:00 8 0.6 9.5 6.1 8.1 0.7 9.9 6.5 53 7 43 305 -12.2 0.1 -11.7 -12.5 12/04/2005 11:40:00 7.6 1.1 11.8 5.7 7.7 1.1 11.5 5.3 47 7 46 305 -12.1 0.1 -11.7 -12.3 12/04/2005 11:50:00 8.5 0.7 9.9 6.5 8.5 0.8 10.3 6.1 45 7 48 305 -11.9 0.1 -11.7 -12.1 12/04/2005 12:00:00 8.9 0.7 11.1 7.2 9 0.8 11.1 6.8 48 7 52 305 -12 0 -11.7 -12.3 12/04/2005 12:10:00 8.6 0.7 10.3 6.8 8.7 0.8 10.7 6.5 49 7 50 305 -12.1 0.1 -11.7 -12.5 12/04/2005 12:20:00 8.3 0.8 10.3 6.5 8.3 0.9 10.3 6.1 52 6 50 305 -12.3 0.1 -11.9 -12.5 12/04/2005 12:30:00 8.7 0.8 10.7 6.5 8.8 0.9 10.7 6.5 45 7 50 305 -12.3 0 -11.9 -12.5 12/04/2005 12:40:00 8.6 0.7 10.3 6.8 8.7 0.8 10.3 6.5 50 8 53 305 -12.3 0 -11.9 -12.5 12/04/2005 12:50:00 9.4 0.9 11.8 6.8 9.4 1 12.2 6.8 41 7 39 305 -12.2 0 -11.9 -12.5 12/04/2005 13:00:00 10.2 0.8 11.8 7.2 10.3 0.9 12.2 7.6 37 5 31 305 -12.5 0 -12.1 -12.7 12/04/2005 13:10:00 9.7 0.8 11.1 6.8 9.8 0.9 11.5 6.5 38 6 35 305 -12.7 0 -12.3 -12.9 12/04/2005 13:20:00 9.6 0.8 11.5 7.2 9.7 0.9 11.5 7.2 39 5 38 305 -12.9 0.1 -12.5 -13.3 12/04/2005 13:30:00 9.3 0.5 10.7 7.6 9.3 0.6 10.7 7.6 33 5 30 305 -13.1 0 -12.7 -13.3 12/04/2005 13:40:00 9.7 0.6 11.5 7.6 9.8 0.7 11.8 7.6 38 7 25 305 -13.2 0 -12.9 -13.3 12/04/2005 13:50:00 9.8 0.7 11.8 8 9.8 0.8 11.5 8 35 6 35 305 -13.2 0.1 -12.9 -13.3 12/04/2005 14:00:00 9.8 0.9 11.8 7.6 9.9 1 12.2 8 40 6 41 305 -13.2 0 -12.9 -13.3 12/04/2005 14:10:00 10 0.9 11.8 8 10.1 1 12.2 8 48 5 42 305 -13.1 0 -12.7 -13.3 12/04/2005 14:20:00 10 0.7 11.5 8 10.2 0.8 12.2 8 46 6 49 305 -13.1 0.1 -12.7 -13.3 12/04/2005 14:30:00 10.3 0.7 11.8 8.4 10.4 0.8 12.2 8.4 36 5 40 305 -13 0.1 -12.5 -13.1 12/04/2005 14:40:00 10.5 0.8 13 8.8 10.5 0.9 12.6 8.4 40 7 43 305 -12.9 0.1 -12.5 -13.1 12/04/2005 14:50:00 10.9 0.8 12.6 8.4 10.9 0.8 13 8.4 35 5 35 305 -13.1 0.1 -12.7 -13.3 12/04/2005 15:00:00 10.3 0.8 13 8 10.3 0.8 12.2 8 42 6 32 305 -13 0.1 -12.5 -13.3 12/04/2005 15:10:00 10.7 0.7 12.2 9.1 10.6 0.8 13 8.4 33 5 43 305 -13 0 -12.7 -13.3 12/04/2005 15:20:00 9.7 1 12.2 7.2 9.8 1 12.2 7.2 48 9 37 305 -13.1 0 -12.7 -13.3 12/04/2005 15:30:00 9.7 0.6 11.5 8.4 9.6 0.7 11.5 7.2 57 7 45 305 -13.2 0 -12.9 -13.3 12/04/2005 15:40:00 9.9 1 12.2 7.6 10 1.1 13 7.6 43 6 47 305 -13.2 0.1 -12.9 -13.5 12/04/2005 15:50:00 10.1 0.7 11.5 8 10.2 0.9 11.8 8 50 6 48 305 -13.2 0 -12.9 -13.3 12/04/2005 16:00:00 9.6 1 11.5 6.5 9.7 1.1 12.2 7.2 47 7 45 305 -13.1 0.1 -12.7 -13.3 12/04/2005 16:10:00 9.5 0.8 11.5 8 9.6 0.8 11.5 7.2 50 9 38 305 -13.1 0 -12.7 -13.3 12/04/2005 16:20:00 10.4 0.9 12.2 6.1 10.4 1 13 5.7 39 8 29 305 -13.2 0.1 -12.7 -13.5 12/04/2005 16:30:00 11.4 0.7 13.3 9.5 11.5 0.7 13.3 9.1 35 5 35 305 -13.4 0.1 -13.1 -13.7 12/04/2005 16:40:00 11.3 1 13 8.4 11.2 1 13.7 7.6 35 4 36 305 -13.5 0.1 -13.3 -13.7 12/04/2005 16:50:00 11.2 0.7 12.6 8.4 11.1 0.7 12.6 8.8 33 5 26 305 -13.6 0 -13.3 -13.7 12/04/2005 17:00:00 11 0.8 13 8 11 0.9 12.6 8 34 5 42 305 -13.8 0 -13.3 -14.1 12/04/2005 17:10:00 10.7 0.8 12.6 8.4 10.7 0.9 13 8.4 31 5 31 305 -14 0.1 -13.7 -14.3 12/04/2005 17:20:00 9.9 0.8 12.2 7.6 9.9 0.9 12.2 7.6 35 6 37 305 -14.3 0.1 -13.9 -14.6 12/04/2005 17:30:00 9.8 0.6 11.1 7.6 9.9 0.7 11.5 8 41 6 37 305 -14.5 0.1 -14.3 -14.6 12/04/2005 17:40:00 9.7 0.9 12.2 7.6 9.7 1 11.5 6.8 37 5 36 305 -14.7 0 -14.3 -14.8 12/04/2005 17:50:00 10 0.9 12.2 7.6 10.1 1 12.2 7.6 42 7 36 305 -14.7 0 -14.3 -14.8 12/04/2005 18:00:00 10 0.8 12.6 7.6 10.1 0.8 12.6 7.6 39 6 39 305 -14.6 0 -14.4 -14.8 12/04/2005 18:10:00 10.3 0.5 11.5 8.8 10.5 0.5 11.8 8.8 39 5 33 305 -14.8 0 -14.4 -15 12/04/2005 18:20:00 9.8 0.7 11.5 8 9.8 0.8 11.8 7.2 38 5 39 305 -14.8 0 -14.6 -15 12/04/2005 18:30:00 10.1 0.8 11.8 8 10.2 0.8 11.8 7.6 40 5 37 305 -15 0.1 -14.6 -15.2 12/04/2005 18:40:00 10.2 0.8 11.8 7.6 10.3 0.8 11.8 8.4 41 6 45 305 -15.1 0 -14.6 -15.2 12/04/2005 18:50:00 10.7 0.8 12.6 8.4 10.8 0.8 12.6 8.4 37 4 36 305 -15.2 0.1 -14.6 -15.2 12/04/2005 19:00:00 10.7 0.9 12.6 7.6 10.7 1 12.6 8 43 5 44 305 -15.3 0 -14.6 -15.6 12/04/2005 19:10:00 11.5 0.9 13 8.8 11.4 1 13.3 8.4 41 5 42 305 -15.5 0 -14.8 -15.6 12/04/2005 19:20:00 12.1 0.8 13.7 9.5 12.1 1 14.1 9.1 41 4 42 305 -15.6 0 -15 -15.6 12/04/2005 19:30:00 11.7 0.9 13.7 8.8 11.6 1 13.7 9.1 42 6 41 305 -15.6 0 -15.4 -15.8 12/04/2005 19:40:00 12.4 1 14.1 9.1 12.3 1 14.1 9.1 39 5 40 305 -15.7 0 -15.4 -16 12/04/2005 19:50:00 12.2 1.2 14.9 9.1 12.2 1.3 14.9 9.1 38 5 36 305 -15.8 0 -15.6 -16 12/04/2005 20:00:00 12.7 1 14.9 9.9 12.7 1.1 15.3 9.9 39 5 40 305 -15.8 0 -15.6 -16 12/04/2005 20:10:00 13.2 1.1 15.3 9.9 13.2 1.1 15.6 9.9 40 5 39 305 -15.8 0 -15.6 -15.8 12/04/2005 20:20:00 11.3 1.1 14.1 8.4 11.2 1.2 14.5 8 39 6 39 305 -15.6 0 -15.2 -15.8 12/04/2005 20:30:00 12.2 1.2 14.1 9.1 12 1.2 14.1 9.1 37 6 22 305 -15.4 0 -15.2 -15.6 12/04/2005 20:40:00 12.7 1 14.5 9.1 12.4 1.2 14.9 9.1 38 5 37 305 -15.4 0 -15.2 -15.6 12/04/2005 20:50:00 12.3 1.1 14.9 9.1 12.3 1.2 15.3 8.8 41 5 41 305 -15.4 0 -15.2 -15.6 12/04/2005 21:00:00 12.8 0.6 14.1 10.7 12.5 0.8 14.1 10.3 34 5 32 305 -15.3 0 -15 -15.6 12/04/2005 21:10:00 12.5 0.8 14.5 9.9 12.3 1 14.5 9.5 34 5 30 305 -15.3 0 -15.2 -15.6 12/04/2005 21:20:00 12.4 0.9 14.5 9.9 12.3 1 14.1 9.1 36 5 36 305 -15.3 0 -15.2 -15.6 12/04/2005 21:30:00 12.1 1.1 14.5 9.1 11.9 1.2 14.9 8 36 5 38 305 -15.3 0 -15 -15.6 12/04/2005 21:40:00 12 1.2 14.5 8.8 11.9 1.2 14.9 8.8 33 5 36 305 -15.2 0 -14.6 -15.4 12/04/2005 21:50:00 12.3 1.2 14.9 9.1 12.2 1.3 14.5 8.8 35 5 36 305 -15.3 0.1 -14.6 -15.6 12/04/2005 22:00:00 12.9 1 15.3 10.3 12.8 1.1 14.9 9.1 34 5 29 305 -15.5 0.1 -15 -15.8 12/04/2005 22:10:00 13.8 1.1 16.4 10.3 13.6 1.2 16.4 9.9 32 5 32 305 -15.7 0.1 -15 -15.8 12/04/2005 22:20:00 14.7 1 16.4 11.8 14.5 1 16.4 11.8 30 5 27 305 -15.7 0 -15 -15.8 12/04/2005 22:30:00 13.9 1.3 16.8 10.7 13.6 1.3 16.4 10.7 30 5 30 305 -15.8 0.1 -15.2 -16 12/04/2005 22:40:00 14.1 1.6 17.2 10.3 13.9 1.6 16.8 9.5 33 5 32 305 -15.8 0 -15 -16 12/04/2005 22:50:00 14.1 1.5 16.8 10.7 13.9 1.6 17.2 9.5 39 6 31 305 -15.9 0.1 -15.2 -16.2 12/04/2005 23:00:00 15.8 1 18.3 12.6 15.6 1.1 17.9 12.2 37 4 42 305 -16 0 -15.6 -16.2 12/04/2005 23:10:00 14.3 1.5 17.9 10.3 14 1.5 17.6 10.7 38 6 32 305 -16 0 -15.6 -16.2 12/04/2005 23:20:00 14.9 1.3 17.6 10.3 14.7 1.4 17.9 10.7 38 5 35 305 -16.1 0 -15.6 -16.2 12/04/2005 23:30:00 15.2 1.1 17.6 11.8 15.1 1.2 17.6 11.1 35 4 36 305 -15.9 0 -15.6 -16.2 12/04/2005 23:40:00 14.8 1.2 17.2 11.5 14.7 1.2 17.6 11.1 37 4 32 305 -15.9 0 -15.4 -16 12/04/2005 23:50:00 16.1 1.2 18.7 12.6 15.9 1.3 18.7 12.2 38 4 41 305 -15.9 0 -15.6 -16 12/05/2005 00:00:00 15.8 1.3 18.3 11.8 15.6 1.4 18.3 11.8 36 4 32 305 -15.9 0 -15.8 -16 12/05/2005 00:10:00 14.2 1.4 17.6 10.7 14.1 1.5 17.9 10.7 37 5 36 305 -15.8 0 -15.6 -16 12/05/2005 00:20:00 14 1.3 17.2 11.1 13.8 1.4 17.2 9.5 37 6 46 305 -15.8 0 -15.6 -16 12/05/2005 00:30:00 14 1.4 16.8 10.3 13.8 1.5 17.2 9.9 37 5 33 305 -16 0 -15.8 -16.2 12/05/2005 00:40:00 14.7 1.3 17.2 10.7 14.3 1.5 17.2 9.9 34 5 27 305 -16 0 -15.8 -16.2 12/05/2005 00:50:00 14.8 1.3 17.2 11.5 14.6 1.4 17.6 11.1 34 5 33 305 -16.1 0 -15.8 -16.2 12/05/2005 01:00:00 14.1 1.5 17.2 10.7 13.9 1.6 17.9 10.3 36 6 29 305 -16.1 0.1 -15.8 -16.4 12/05/2005 01:10:00 15.5 1.2 17.6 11.5 15.2 1.3 17.9 11.5 34 5 34 305 -16.2 0 -16 -16.4 12/05/2005 01:20:00 14.2 1.2 17.2 10.7 14 1.2 17.2 10.7 35 6 39 305 -16 0 -15.8 -16.2 12/05/2005 01:30:00 14.1 1.3 16.8 10.7 13.9 1.3 17.2 10.7 37 5 37 305 -16 0 -15.8 -16.2 12/05/2005 01:40:00 13.4 1.3 17.9 9.9 13.3 1.4 17.9 9.5 38 6 35 305 -15.9 0 -15.8 -16.2 12/05/2005 01:50:00 13.1 1.4 16.4 9.9 13.1 1.5 16.8 10.3 36 6 31 305 -15.9 0 -15.8 -16 12/05/2005 02:00:00 13.6 1.4 16.1 9.9 13.4 1.3 16.1 9.9 32 6 29 305 -15.8 0 -15.8 -16 12/05/2005 02:10:00 13.1 1.2 16.1 9.9 12.8 1.1 15.6 9.1 37 6 31 305 -15.8 0 -15.6 -16 12/05/2005 02:20:00 15.3 1.5 18.3 11.1 15 1.5 18.3 10.7 37 5 44 305 -15.8 0 -15.4 -16 12/05/2005 02:30:00 13.9 1.3 16.8 10.3 13.7 1.3 16.4 10.3 35 5 33 305 -15.8 0 -15.6 -16 12/05/2005 02:40:00 14.8 1.3 17.6 11.5 14.6 1.4 17.6 11.5 37 5 39 305 -15.8 0 -15.6 -16 12/05/2005 02:50:00 15.3 1.7 18.7 10.7 15 1.8 18.7 9.9 33 5 31 305 -15.7 0 -15.6 -15.8 12/05/2005 03:00:00 16.9 1.3 19.9 12.6 16.6 1.3 19.1 12.6 38 4 39 305 -15.8 0 -15.6 -16 12/05/2005 03:10:00 16.7 1.5 20.2 12.2 16.5 1.6 20.6 11.1 37 5 39 305 -15.9 0 -15.8 -16.2 12/05/2005 03:20:00 16.9 1.2 19.9 13.3 16.8 1.3 20.2 13 42 5 34 305 -16 0 -15.8 -16.2 12/05/2005 03:30:00 16.1 1.3 18.7 12.6 15.8 1.4 18.7 12.2 40 5 33 305 -15.8 0 -15.6 -16 12/05/2005 03:40:00 16.7 1.9 20.6 11.8 16.6 1.9 21 12.2 39 5 36 305 -15.8 0 -15.6 -16 12/05/2005 03:50:00 17.6 1.3 20.2 13.7 17.4 1.4 19.9 13.3 39 5 53 305 -15.9 0 -15.8 -16 12/05/2005 04:00:00 17.4 1.7 20.6 12.6 17.2 1.7 21 12.6 38 5 41 305 -15.8 0 -15.2 -16 12/05/2005 04:10:00 17.8 1.4 20.6 13.7 17.5 1.5 20.6 13.7 40 5 40 305 -15.9 0 -15.4 -16 12/05/2005 04:20:00 17.6 1.3 20.6 13.3 17.4 1.5 20.6 13.3 41 5 47 305 -15.8 0 -15.6 -16 12/05/2005 04:30:00 17.7 1.4 21 13.7 17.5 1.6 20.6 13 41 5 49 305 -15.8 0 -15.6 -16 12/05/2005 04:40:00 18.1 1.7 22.6 13.7 17.8 1.7 22.9 13 43 5 41 305 -15.7 0 -15.6 -15.8 12/05/2005 04:50:00 18.5 1.4 22.1 14.5 18.2 1.6 22.1 13.7 42 5 45 305 -15.4 0 -15.2 -15.6 12/05/2005 05:00:00 18.9 1.6 22.1 14.9 18.8 1.7 22.1 14.5 43 4 40 305 -15.3 0 -15 -15.6 12/05/2005 05:10:00 18.9 1.4 21.8 14.1 18.6 1.5 21.8 14.5 41 5 39 305 -15.2 0 -14.8 -15.2 12/05/2005 05:20:00 17.4 1.5 20.6 13.3 17.2 1.5 20.6 13 40 5 46 305 -15.1 0 -14.8 -15.2 12/05/2005 05:30:00 17.5 1.6 21.4 13.7 17.4 1.6 21.4 13.3 40 5 41 305 -15.2 0 -15 -15.2 12/05/2005 05:40:00 17.3 1.4 20.2 13 17.1 1.4 19.9 13 38 4 38 305 -15.1 0 -15 -15.2 12/05/2005 05:50:00 16.7 1.6 19.9 11.8 16.3 1.6 19.9 11.8 38 5 37 305 -15.1 0 -15 -15.2 12/05/2005 06:00:00 16.9 1.3 19.5 13.3 16.5 1.4 19.5 12.6 38 5 38 305 -15 0.1 -14.6 -15.2 12/05/2005 06:10:00 17.7 1.7 21.4 13.3 17.4 1.8 21.8 13 42 5 46 305 -14.8 0 -14.6 -15 12/05/2005 06:20:00 18.8 1.2 21.8 14.9 18.5 1.3 22.1 14.5 42 4 42 305 -14.8 0 -14.6 -15 12/05/2005 06:30:00 18.8 1.8 22.6 14.1 18.5 2 23.3 13.7 41 5 39 305 -14.7 0 -14.6 -14.8 12/05/2005 06:40:00 19.3 1.9 23.3 14.5 18.9 2 23.3 13.7 41 5 42 305 -14.7 0 -14.4 -14.6 12/05/2005 06:50:00 19.1 1.5 22.1 14.9 18.8 1.6 22.9 13.7 41 5 43 305 -14.6 0.1 -14.3 -14.6 12/05/2005 07:00:00 17.7 1.7 21.4 13.3 17.6 1.7 21.4 13.3 43 5 45 305 -14.5 0.1 -14.3 -14.6 12/05/2005 07:10:00 17.7 1.4 21 13.7 17.5 1.4 20.6 14.1 43 5 48 305 -14.4 0 -14.3 -14.6 12/05/2005 07:20:00 18 1.6 21.4 14.1 17.6 1.7 21.8 13 40 5 42 305 -14.4 0 -14.1 -14.6 12/05/2005 07:30:00 17.8 1.8 21.8 12.6 17.6 1.9 22.1 13.3 39 5 39 305 -14.3 0 -13.9 -14.4 12/05/2005 07:40:00 17.3 1.7 21.4 13 17.1 1.7 21.4 13.3 41 5 34 305 -14.2 0 -13.9 -14.4 12/05/2005 07:50:00 17.3 1.7 20.2 12.6 17 1.7 20.2 12.6 41 5 42 305 -14.2 0 -13.9 -14.4 12/05/2005 08:00:00 16.9 1.5 20.2 13 16.7 1.6 20.2 12.6 39 4 43 305 -14.2 0 -13.9 -14.3 12/05/2005 08:10:00 17.3 1.5 21 13.7 17.1 1.5 20.2 13.3 39 5 45 305 -14.2 0 -13.9 -14.3 12/05/2005 08:20:00 17.8 1.7 22.9 13.7 17.5 1.7 22.6 13.7 39 6 33 305 -14.2 0 -13.9 -14.3 12/05/2005 08:30:00 17.9 1.7 21.4 13.3 17.5 1.8 21 12.2 38 5 38 305 -14.2 0 -13.9 -14.3 12/05/2005 08:40:00 16.9 2.1 20.6 12.6 16.7 2 21 12.2 39 5 38 305 -14.2 0 -13.9 -14.3 12/05/2005 08:50:00 18.5 1.5 22.1 13.3 18.3 1.5 21 13.3 38 4 41 305 -14.3 0 -13.9 -14.6 12/05/2005 09:00:00 17 1.7 20.6 12.2 16.8 1.7 21 12.2 39 5 39 305 -14.4 0 -14.1 -14.4 12/05/2005 09:10:00 16.9 1.5 19.9 13 16.6 1.5 19.9 13 41 6 36 305 -14.4 0 -14.1 -14.4 12/05/2005 09:20:00 16.1 1.6 19.1 11.1 15.8 1.7 19.1 11.1 44 5 44 305 -14.4 0 -14.3 -14.6 12/05/2005 09:30:00 15.9 1.8 19.9 10.7 15.8 1.8 19.9 10.3 44 5 50 305 -14.4 0 -14.3 -14.6 12/05/2005 09:40:00 16.2 1.7 19.9 11.8 16 1.7 19.9 11.5 42 5 46 305 -14.3 0 -14.3 -14.4 12/05/2005 09:50:00 16.3 1.6 20.6 11.1 16 1.6 20.2 10.7 40 5 38 305 -14.2 0 -14.1 -14.3 12/05/2005 10:00:00 16.3 1.7 21 12.2 16.1 1.8 21.4 11.1 41 5 43 305 -14.1 0 -13.7 -14.3 12/05/2005 10:10:00 16.7 1.9 21 12.6 16.5 1.9 21 11.8 40 6 39 305 -14.1 0 -13.7 -14.3 12/05/2005 10:20:00 16.7 1.7 19.9 12.6 16.4 1.7 20.6 11.8 40 6 33 305 -14.1 0 -13.7 -14.3 12/05/2005 10:30:00 15.4 1.9 20.6 10.7 15.2 2 19.5 11.1 39 5 42 305 -14.1 0 -13.7 -14.3 12/05/2005 10:40:00 15.6 1.9 19.5 9.9 15.4 1.9 19.5 10.3 41 5 40 305 -14.1 0 -13.7 -14.3 12/05/2005 10:50:00 15.4 1.6 19.9 11.1 15.1 1.6 19.1 11.1 41 6 35 305 -14.1 0 -13.7 -14.3 12/05/2005 11:00:00 16.6 1.5 19.9 13 16.3 1.5 19.9 12.6 42 6 49 305 -14.2 0 -13.9 -14.3 12/05/2005 11:10:00 16.4 2 20.6 11.8 16.1 2 21 11.8 41 5 40 305 -14.2 0 -14.1 -14.3 12/05/2005 11:20:00 17.1 1.3 20.6 13 16.8 1.5 20.6 13 41 5 42 305 -14.2 0 -13.9 -14.4 12/05/2005 11:30:00 16.9 1.5 20.2 12.6 16.5 1.6 20.2 12.6 42 5 47 305 -14.4 0.1 -14.1 -14.6 12/05/2005 11:40:00 15.6 1.6 19.1 11.5 15.4 1.6 18.7 11.1 44 5 45 305 -14.6 0.1 -14.3 -14.6 12/05/2005 11:50:00 15.3 1.3 18.7 11.1 15 1.5 18.3 10.7 40 5 44 305 -14.7 0 -14.4 -14.8 12/05/2005 12:00:00 15.6 2.6 21 10.3 15.3 2.6 21.4 10.3 40 6 39 305 -14.7 0 -14.4 -14.8 12/05/2005 12:10:00 17.5 1.3 20.2 13.3 17.1 1.4 19.9 12.6 37 4 38 305 -14.8 0 -14.6 -15 12/05/2005 12:20:00 16.1 1.7 20.6 11.5 15.8 1.7 19.5 11.5 39 5 38 305 -14.9 0 -14.6 -15 12/05/2005 12:30:00 16.4 1.5 19.5 11.1 16.1 1.5 19.5 12.2 40 7 30 305 -14.9 0.1 -14.6 -15 12/05/2005 12:40:00 16.8 1.5 20.2 13 16.5 1.6 20.2 13 42 5 36 305 -15.1 0.1 -14.6 -15.2 12/05/2005 12:50:00 15.9 1.5 19.5 12.2 15.7 1.6 20.6 12.2 41 5 37 305 -15 0 -14.6 -15 12/05/2005 13:00:00 16.6 1.3 19.5 11.8 16.3 1.4 19.1 12.6 39 5 35 305 -14.9 0 -14.6 -15 12/05/2005 13:10:00 15.6 1.6 19.1 9.9 15.4 1.5 18.7 11.5 40 6 48 305 -14.9 0 -14.6 -15 12/05/2005 13:20:00 16 1.5 19.9 12.2 15.8 1.5 19.5 11.8 41 5 42 305 -14.8 0 -14.6 -15 12/05/2005 13:30:00 15.1 1.5 18.7 11.1 15 1.6 19.1 10.7 42 5 40 305 -14.8 0 -14.6 -14.8 12/05/2005 13:40:00 14.6 1.4 17.9 11.1 14.5 1.4 17.9 10.7 41 5 36 305 -14.7 0 -14.4 -14.8 12/05/2005 13:50:00 14.9 1.5 17.9 11.5 14.7 1.7 18.3 9.9 40 6 31 305 -14.5 0 -14.3 -14.6 12/05/2005 14:00:00 17.3 1.5 20.2 12.6 17 1.7 20.6 12.6 40 5 37 305 -14.5 0 -14.3 -14.6 12/05/2005 14:10:00 14.6 1.7 19.1 11.1 14.4 1.9 19.1 10.7 43 5 47 305 -14.5 0 -14.4 -14.6 12/05/2005 14:20:00 16.5 1.7 20.6 11.8 16.2 1.8 20.2 11.1 44 5 46 305 -14.4 0 -14.3 -14.6 12/05/2005 14:30:00 16.2 1.6 19.9 11.8 15.9 1.8 20.2 11.5 44 5 35 305 -14.4 0 -14.3 -14.6 12/05/2005 14:40:00 15.9 1.4 19.5 12.6 15.7 1.5 19.9 12.2 43 5 36 305 -14.3 0 -14.3 -14.4 12/05/2005 14:50:00 15.1 1.6 18.7 11.8 14.8 1.7 18.7 11.5 45 6 41 305 -14.2 0 -14.1 -14.3 12/05/2005 15:00:00 15.9 1.3 19.1 12.6 15.7 1.3 19.1 12.2 44 5 44 305 -14.1 0 -13.7 -14.3 12/05/2005 15:10:00 14.6 1.7 18.3 11.1 14.4 1.7 18.3 10.7 43 5 41 305 -14 0 -13.7 -14.3 12/05/2005 15:20:00 14.6 1.5 17.9 9.9 14.3 1.6 17.6 9.9 42 5 37 305 -13.9 0 -13.7 -14.1 12/05/2005 15:30:00 13.4 1.7 18.3 9.9 13.2 1.6 18.3 9.9 39 6 32 305 -13.8 0 -13.7 -13.9 12/05/2005 15:40:00 15 1.5 19.1 11.5 14.7 1.6 19.5 11.1 38 6 42 305 -13.6 0 -13.5 -13.7 12/05/2005 15:50:00 16.6 1.9 20.6 12.6 16.2 1.9 20.6 11.8 37 5 34 305 -13.5 0.1 -13.1 -13.7 12/05/2005 16:00:00 15.1 1.8 19.5 11.1 14.8 1.8 19.5 11.1 37 5 36 305 -13.5 0.1 -13.1 -13.7 12/05/2005 16:10:00 17.6 1.5 21 13 17.3 1.5 20.6 13 36 5 32 305 -13.5 0.1 -13.1 -13.7 12/05/2005 16:20:00 18.2 1.8 22.6 13.3 17.9 1.9 22.6 12.6 38 5 40 305 -13.5 0.1 -13.1 -13.7 12/05/2005 16:30:00 17.8 1.7 22.9 13.3 17.5 1.7 22.1 12.2 38 5 34 305 -13.6 0 -13.3 -13.7 12/05/2005 16:40:00 17.9 1.5 21.4 13.7 17.5 1.5 21.4 13.3 38 5 49 305 -13.6 0 -13.1 -13.7 12/05/2005 16:50:00 18.6 1.7 22.1 13.3 18.2 1.7 22.1 13.7 35 4 30 305 -13.4 0.1 -13.1 -13.7 12/05/2005 17:00:00 18.5 1.6 22.1 14.1 18 1.6 21.4 13.7 35 5 41 305 -13.5 0.1 -13.1 -13.7 12/05/2005 17:10:00 17.6 1.7 21.4 13 17.3 1.7 21.8 13 38 5 37 305 -13.4 0.1 -13.1 -13.7 12/05/2005 17:20:00 17.1 1.5 21.8 13.3 16.8 1.6 21.8 12.6 36 6 37 305 -13.4 0.1 -12.9 -13.5 12/05/2005 17:30:00 17.3 1.7 21.4 13.3 17 1.7 21.4 12.2 37 5 38 305 -13.4 0.1 -12.9 -13.7 12/05/2005 17:40:00 18 2 22.6 13.3 17.5 1.9 22.6 12.6 36 6 31 305 -13.4 0.1 -13.1 -13.7 12/05/2005 17:50:00 18.4 1.7 22.9 14.1 18 1.7 22.1 13 33 5 31 305 -13.4 0.1 -13.1 -13.7 12/05/2005 18:00:00 16.9 1.9 21 11.8 16.4 1.8 20.6 12.2 34 6 26 305 -13.4 0.1 -12.9 -13.7 12/05/2005 18:10:00 17.7 1.9 22.9 12.6 17.2 1.8 22.6 12.2 33 5 32 305 -13.4 0 -12.9 -13.5 12/05/2005 18:20:00 18.3 2.3 24.4 12.6 17.7 2.2 24 12.6 31 5 29 305 -13.4 0 -13.3 -13.5 12/05/2005 18:30:00 17.8 2 22.6 12.6 17.3 2 22.6 12.6 34 5 32 305 -13.4 0 -13.3 -13.5 12/05/2005 18:40:00 17.1 2 22.1 12.6 16.7 2.1 21.8 12.2 34 5 37 305 -13.5 0 -13.3 -13.7 12/05/2005 18:50:00 17.7 2.2 22.6 12.2 17.4 2.2 21.8 12.2 35 5 33 305 -13.5 0 -13.3 -13.7 12/05/2005 19:00:00 18 2.3 23.3 11.8 17.7 2.3 23.7 12.2 35 5 32 305 -13.4 0 -13.3 -13.7 12/05/2005 19:10:00 16.7 2.2 21.4 12.2 16.4 2.3 21.8 11.8 35 5 45 305 -13.4 0 -12.9 -13.5 12/05/2005 19:20:00 16.8 1.8 21 12.6 16.4 1.7 21 12.2 33 6 34 305 -13.4 0 -13.1 -13.7 12/05/2005 19:30:00 16.6 2.2 21.8 11.8 16.3 2.2 21.4 11.8 37 6 33 305 -13.4 0 -13.3 -13.5 12/05/2005 19:40:00 16.8 1.8 22.1 12.6 16.3 1.9 21 12.2 34 5 31 305 -13.3 0 -13.1 -13.5 12/05/2005 19:50:00 17.3 2 22.1 12.2 17 2 22.1 12.2 36 6 39 305 -13.3 0 -13.1 -13.5 12/05/2005 20:00:00 17.1 2.3 21.4 11.5 16.7 2.3 22.1 11.5 34 5 32 305 -13.1 0 -12.7 -13.3 12/05/2005 20:10:00 18.7 2 23.3 13.7 18.1 2 22.1 13 33 5 33 305 -13.1 0 -12.7 -13.3 12/05/2005 20:20:00 19.7 2 24.8 14.5 19.2 2.1 25.2 13.3 34 6 34 305 -13.1 0 -12.9 -13.3 12/05/2005 20:30:00 18.1 2.1 24 13.3 17.7 2 23.7 13 38 6 30 305 -13.1 0 -12.9 -13.3 12/05/2005 20:40:00 17.2 1.6 21 13.3 16.7 1.6 20.6 13.3 36 6 33 305 -13.1 0 -12.9 -13.3 12/05/2005 20:50:00 18.2 2.7 25.2 12.6 17.6 2.7 24 11.5 35 6 32 305 -13.2 0.1 -12.9 -13.5 12/05/2005 21:00:00 19.3 1.9 24 14.5 18.9 1.9 23.7 13.7 38 5 36 305 -13.4 0.1 -12.9 -13.7 12/05/2005 21:10:00 19.5 1.9 23.7 14.1 19 2 24 14.1 33 6 37 305 -13.5 0.1 -13.1 -13.7 12/05/2005 21:20:00 19.7 2.3 24.8 14.1 19.2 2.3 24.8 13 33 5 44 305 -13.6 0.1 -13.1 -13.9 12/05/2005 21:30:00 17.2 1.9 22.1 13.3 16.9 1.9 21.4 12.2 34 6 32 305 -13.5 0.1 -13.1 -13.7 12/05/2005 21:40:00 15.9 1.9 20.2 11.5 15.6 1.9 20.2 11.8 32 6 32 305 -13.5 0.1 -12.9 -13.7 12/05/2005 21:50:00 17.5 1.9 22.1 13 17.1 1.7 21.4 12.6 35 7 27 305 -13.6 0.1 -13.1 -13.7 12/05/2005 22:00:00 18.4 1.8 24 12.6 17.9 1.7 23.3 13.7 31 6 31 305 -13.8 0 -13.3 -14.1 12/05/2005 22:10:00 19.5 1.9 24 14.5 18.9 1.9 22.9 13.7 32 6 35 305 -13.9 0.1 -13.5 -14.3 12/05/2005 22:20:00 19.3 2.2 24.8 14.1 18.7 2.1 23.3 13.3 32 6 23 305 -14 0.1 -13.7 -14.3 12/05/2005 22:30:00 19.7 1.8 23.7 14.1 19.4 1.9 23.7 14.1 35 6 36 305 -14.1 0.1 -13.7 -14.3 12/05/2005 22:40:00 19.4 2.3 23.7 12.6 18.9 2.1 23.7 12.6 30 5 34 305 -14 0.1 -13.7 -14.3 12/05/2005 22:50:00 18.8 2.2 24.4 13.7 18.1 2.2 23.7 13.7 31 6 29 305 -14 0 -13.7 -14.3 12/05/2005 23:00:00 18.9 1.8 22.6 13.7 18.6 1.8 22.9 13.3 33 6 35 305 -14.1 0 -13.7 -14.3 12/05/2005 23:10:00 17.9 2 22.9 12.2 17.6 2 22.6 11.5 32 6 32 305 -14.1 0 -13.9 -14.3 12/05/2005 23:20:00 17.8 2.1 22.6 12.2 17.5 2.1 22.9 13 33 5 36 305 -14.1 0 -13.9 -14.3 12/05/2005 23:30:00 18 2.1 22.9 13.3 17.6 2 22.6 13.3 32 5 35 305 -14.1 0 -13.9 -14.3 12/05/2005 23:40:00 18.8 2.2 22.9 13.3 18.4 2.1 22.9 12.6 33 5 29 305 -14.2 0 -13.7 -14.3 12/05/2005 23:50:00 18.5 2.2 22.9 12.2 18 2.2 22.1 11.5 30 5 30 305 -14.2 0 -13.9 -14.4 12/06/2005 00:00:00 19.2 1.9 23.3 14.1 18.7 1.9 22.9 12.6 29 5 32 305 -14.3 0 -14.1 -14.4 12/06/2005 00:10:00 18.6 2.1 24 13 18.2 1.9 23.3 13 29 6 27 305 -14.2 0 -14.1 -14.3 12/06/2005 00:20:00 18.5 2.1 24.4 12.6 18 2.1 23.3 11.5 29 6 33 305 -14.3 0 -14.3 -14.4 12/06/2005 00:30:00 18 1.9 22.9 13 17.6 1.9 22.6 12.6 28 6 29 305 -14.3 0 -14.1 -14.4 12/06/2005 00:40:00 18.2 2.2 22.9 12.2 17.8 2.2 22.9 12.6 30 6 30 305 -14.3 0 -14.3 -14.4 12/06/2005 00:50:00 18.5 1.9 23.3 13 18.1 1.8 22.1 13 31 5 25 305 -14.4 0 -14.3 -14.6 12/06/2005 01:00:00 19.7 2.5 24.8 13.7 19.1 2.4 24.4 13.3 30 5 27 305 -14.4 0 -14.3 -14.6 12/06/2005 01:10:00 19.2 1.9 23.3 14.1 18.7 1.7 22.6 13.7 31 5 23 305 -14.4 0.1 -14.3 -14.6 12/06/2005 01:20:00 18.5 1.8 22.9 14.1 18.1 1.7 22.1 14.5 29 6 29 305 -14.4 0 -14.1 -14.6 12/06/2005 01:30:00 19.2 2.1 23.7 13.3 18.7 2 22.9 14.1 30 6 32 305 -14.4 0 -14.1 -14.6 12/06/2005 01:40:00 19.4 2.4 25.2 13 19 2.4 25.2 13.3 31 5 30 305 -14.3 0 -14.1 -14.4 12/06/2005 01:50:00 19.5 2.6 24.8 13.3 19 2.6 25.2 13.3 31 5 33 305 -14.3 0 -13.9 -14.4 12/06/2005 02:00:00 18.5 2.7 25.2 13 18.2 2.5 24.8 12.2 33 6 33 305 -14.3 0 -14.1 -14.4 12/06/2005 02:10:00 18.6 2.3 25.2 13 18.2 2.3 24.8 13.3 32 6 36 305 -14.3 0 -14.1 -14.4 12/06/2005 02:20:00 18.5 2.3 23.3 13.3 18.1 2.1 22.6 13.3 32 6 23 305 -14.4 0 -14.1 -14.6 12/06/2005 02:30:00 19 2.4 24.8 13.7 18.5 2.4 24.8 12.6 32 6 29 305 -14.4 0 -14.3 -14.6 12/06/2005 02:40:00 20.1 1.9 24 14.5 19.5 2.1 23.7 14.1 32 5 38 305 -14.4 0.1 -14.3 -14.6 12/06/2005 02:50:00 20.3 2 25.2 14.9 19.8 2 24.4 14.5 29 5 34 305 -14.5 0.1 -14.3 -14.6 12/06/2005 03:00:00 19.7 2.1 24.8 14.5 19.2 2 24 13.7 28 5 29 305 -14.5 0.1 -14.3 -14.6 12/06/2005 03:10:00 19.7 1.8 24 14.9 19.3 1.9 24 14.1 29 5 24 305 -14.6 0.1 -14.3 -14.6 12/06/2005 03:20:00 20.4 1.7 24.8 15.6 19.9 1.8 24.4 14.9 29 5 30 305 -14.7 0 -14.3 -14.6 12/06/2005 03:30:00 20.5 2 24 14.5 19.9 2 23.7 14.5 27 5 22 305 -14.7 0 -14.3 -14.6 12/06/2005 03:40:00 19.5 1.9 23.3 14.5 19 1.9 23.7 13.7 28 5 24 305 -14.7 0 -14.3 -14.6 12/06/2005 03:50:00 19.5 1.5 23.3 16.1 18.8 1.6 22.9 15.6 28 5 30 305 -14.7 0 -14.3 -14.6 12/06/2005 04:00:00 19.4 1.8 23.3 14.9 18.9 1.8 22.9 13.3 29 6 29 305 -14.5 0 -14.3 -14.6 12/06/2005 04:10:00 20.5 1.8 25.2 15.6 19.9 1.9 25.2 15.6 28 5 27 305 -14.6 0.1 -14.3 -14.6 12/06/2005 04:20:00 20.1 2 24.8 15.6 19.5 2 24.4 14.9 28 5 29 305 -14.6 0 -14.4 -14.6 12/06/2005 04:30:00 20.8 1.9 24.8 15.3 20.2 1.9 24.8 16.1 27 5 25 305 -14.7 0 -14.4 -14.8 12/06/2005 04:40:00 19.9 1.7 23.3 15.3 19.4 1.8 24 14.9 25 5 23 305 -14.7 0 -14.4 -14.6 12/06/2005 04:50:00 20.6 1.7 24.4 15.6 19.9 1.8 24.4 14.9 24 5 25 305 -14.7 0 -14.4 -14.8 12/06/2005 05:00:00 20.5 1.9 24.8 15.6 19.9 1.9 24.4 16.1 25 5 23 305 -14.7 0 -14.3 -14.6 12/06/2005 05:10:00 20 2 25.6 14.1 19.5 2 24.8 14.1 26 5 25 305 -14.6 0 -14.3 -14.6 12/06/2005 05:20:00 20.6 1.8 25.6 16.1 20 1.9 24.8 15.3 26 6 23 305 -14.5 0.1 -14.3 -14.6 12/06/2005 05:30:00 20.3 2 25.2 15.6 19.7 2.1 24.8 15.3 26 6 22 305 -14.4 0 -14.3 -14.6 12/06/2005 05:40:00 19 2.1 24 14.5 18.6 2.1 24.4 13.7 25 5 27 305 -14.5 0.1 -14.3 -14.6 12/06/2005 05:50:00 20.3 1.7 23.7 14.9 19.8 1.8 23.7 14.9 24 5 22 305 -14.6 0.1 -14.3 -14.6 12/06/2005 06:00:00 19.9 1.7 23.3 14.5 19.4 1.8 23.7 14.1 26 5 21 305 -14.6 0.1 -14.3 -14.6 12/06/2005 06:10:00 19.3 1.9 24.4 14.5 18.8 1.9 24.4 14.5 25 5 30 305 -14.6 0.1 -14.3 -14.6 12/06/2005 06:20:00 19.2 1.9 23.7 14.1 18.7 1.8 23.7 13.3 27 6 28 305 -14.4 0 -14.3 -14.6 12/06/2005 06:30:00 19.6 2.1 24.4 14.5 19.1 2.2 24 13 26 5 25 305 -14.5 0.1 -14.3 -14.6 12/06/2005 06:40:00 19.5 1.7 23.7 14.1 19 1.8 22.9 14.1 24 5 20 305 -14.5 0.1 -14.3 -14.6 12/06/2005 06:50:00 19.9 2.2 25.6 14.5 19.5 2.2 25.6 13.3 24 5 20 305 -14.6 0.1 -14.3 -14.6 12/06/2005 07:00:00 19.5 2.5 25.6 13.7 19 2.4 25.6 13.3 24 5 23 305 -14.6 0.1 -14.3 -14.6 12/06/2005 07:10:00 20.6 2.3 26.8 14.5 20.2 2.3 27.5 14.1 26 5 25 305 -14.7 0 -14.3 -14.8 12/06/2005 07:20:00 21.4 2.2 26.3 15.6 20.7 2.2 25.2 15.3 25 5 18 305 -14.7 0 -14.4 -14.8 12/06/2005 07:30:00 20.8 2.2 26.3 16.1 20.2 2.2 26.3 15.3 25 6 23 305 -14.7 0 -14.4 -14.6 12/06/2005 07:40:00 22 2.2 26 16.8 21.3 1.9 26 16.4 27 6 31 305 -14.6 0 -14.3 -14.6 12/06/2005 07:50:00 21.7 2.5 26.3 16.1 21.2 2.5 26.8 14.1 26 5 20 305 -14.7 0 -14.4 -14.8 12/06/2005 08:00:00 21.1 2.5 26 15.3 20.3 2.4 25.2 14.9 27 5 27 305 -14.7 0 -14.4 -14.8 12/06/2005 08:10:00 20.9 2.4 25.2 15.3 20.2 2.4 24.8 14.1 26 5 24 305 -14.7 0 -14.4 -14.8 12/06/2005 08:20:00 22 2.2 27.5 16.1 21.3 2.3 26 15.3 25 5 21 305 -14.7 0 -14.3 -14.8 12/06/2005 08:30:00 21.1 2.1 26.3 15.6 20.5 2.2 25.6 14.5 26 5 22 305 -14.7 0 -14.4 -14.6 12/06/2005 08:40:00 21 2 25.6 15.6 20.3 1.9 24.8 15.6 25 5 22 305 -14.7 0 -14.4 -14.6 12/06/2005 08:50:00 20.6 2.3 25.2 15.6 20.1 2.4 25.6 14.1 22 6 22 305 -14.7 0 -14.4 -14.8 12/06/2005 09:00:00 20.2 2.3 25.6 14.1 19.6 2.3 24.4 13.7 23 6 24 305 -14.7 0 -14.3 -14.8 12/06/2005 09:10:00 20.9 2.1 25.6 15.3 20.5 2.1 25.2 14.5 24 6 26 305 -14.6 0.1 -14.3 -14.6 12/06/2005 09:20:00 21.4 2.1 26 16.1 20.8 2.2 26 16.1 23 5 23 305 -14.4 0 -14.3 -14.6 12/06/2005 09:30:00 20.4 1.7 24.8 15.6 20 1.9 24.8 15.3 23 6 20 305 -14.4 0 -14.1 -14.6 12/06/2005 09:40:00 20.5 2.4 26 14.1 20.1 2.4 25.2 14.5 25 6 25 305 -14.3 0 -13.9 -14.6 12/06/2005 09:50:00 19.6 2.1 23.3 14.1 19.2 2 23.7 14.1 25 6 35 305 -14.2 0 -13.7 -14.4 12/06/2005 10:00:00 20.6 2.2 26 15.6 20.2 2 25.6 16.1 25 6 29 305 -14.2 0 -13.9 -14.4 12/06/2005 10:10:00 20 2.4 25.6 13.3 19.6 2.4 24.8 14.5 25 6 28 305 -14.2 0 -13.7 -14.4 12/06/2005 10:20:00 21.1 2.4 26.8 15.3 20.5 2.4 26.8 14.5 27 6 23 305 -14.3 0 -13.9 -14.4 12/06/2005 10:30:00 20 2.5 26.3 14.9 19.6 2.6 26.8 14.5 27 6 21 305 -14.3 0 -14.1 -14.4 12/06/2005 10:40:00 21.8 2.3 26.3 15.6 21.2 2.3 27.1 14.9 27 6 30 305 -14.4 0.1 -14.1 -14.6 12/06/2005 10:50:00 20.3 2.3 26 14.9 19.7 2.2 24.4 14.5 26 6 32 305 -14.4 0 -14.1 -14.6 12/06/2005 11:00:00 21.4 2.5 26.8 14.9 21 2.4 26 14.9 24 5 22 305 -14.4 0 -14.3 -14.6 12/06/2005 11:10:00 21.3 1.7 25.2 16.4 20.8 1.7 25.6 15.6 28 5 30 305 -14.4 0 -14.3 -14.6 12/06/2005 11:20:00 20.2 2.1 25.2 14.5 19.7 2.1 24.8 14.1 27 6 25 305 -14.4 0 -14.3 -14.6 12/06/2005 11:30:00 19.6 2.7 26.3 14.1 19.3 2.7 26.8 13.7 25 6 27 305 -14.4 0 -14.1 -14.6 12/06/2005 11:40:00 19.4 2.2 24.8 14.1 19 2.1 24 13 26 6 29 305 -14.2 0 -13.9 -14.4 12/06/2005 11:50:00 20.4 2.1 24.8 15.6 20 2.1 25.6 14.9 24 6 25 305 -14.2 0 -13.9 -14.4 12/06/2005 12:00:00 20.6 2.4 24.8 14.1 20.2 2.3 24.4 14.1 24 5 25 305 -14.2 0 -13.9 -14.4 12/06/2005 12:10:00 19.4 2.3 25.6 13.7 19.1 2.4 26.3 13 24 6 22 305 -14.2 0 -13.7 -14.4 12/06/2005 12:20:00 19.2 2.3 25.6 13.3 18.8 2.2 24.8 13.7 26 6 17 305 -14.2 0 -13.9 -14.3 12/06/2005 12:30:00 18.8 2.1 24.8 13.3 18.4 2.1 24 13 25 7 21 305 -14.2 0 -13.7 -14.3 12/06/2005 12:40:00 20.4 2.3 25.6 14.1 19.8 2.4 25.2 13.7 27 6 27 305 -14.2 0 -13.7 -14.3 12/06/2005 12:50:00 20.2 2.3 25.6 14.9 19.7 2.4 26 14.1 25 6 26 305 -14.2 0 -13.7 -14.3 12/06/2005 13:00:00 18.8 2.3 25.6 13.3 18.3 2.2 23.7 12.6 27 6 25 305 -14.1 0 -13.7 -14.3 12/06/2005 13:10:00 20.5 2.2 25.6 15.6 19.9 2.2 25.6 12.6 25 6 30 305 -14.2 0 -13.7 -14.3 12/06/2005 13:20:00 20.7 2.2 25.6 14.9 20.4 2.1 25.6 14.9 22 5 16 305 -14.2 0 -13.7 -14.3 12/06/2005 13:30:00 19.4 2.2 24.8 14.1 18.8 2.2 24.8 13.7 22 6 17 305 -14.2 0 -13.7 -14.3 12/06/2005 13:40:00 20.4 2.3 25.2 14.9 19.8 2.3 24.8 14.1 25 6 29 305 -14.1 0.1 -13.7 -14.3 12/06/2005 13:50:00 18.9 2.2 24 13 18.5 2.1 23.3 13 23 7 18 305 -14 0 -13.7 -14.3 12/06/2005 14:00:00 18.3 2.1 24.8 13.7 18 2 25.2 13.7 21 6 26 305 -14 0 -13.7 -14.3 12/06/2005 14:10:00 19.6 2.7 26 14.1 19.3 2.6 25.6 14.5 23 6 18 305 -14 0.1 -13.7 -14.3 12/06/2005 14:20:00 19.7 2.3 24.8 13 19.1 2.5 25.2 13 23 6 25 305 -14 0 -13.7 -14.3 12/06/2005 14:30:00 19.5 2 24.8 14.1 19 1.9 24.4 13.7 22 6 19 305 -14 0.1 -13.7 -14.3 12/06/2005 14:40:00 20.3 2.4 24.8 13 19.8 2.4 24.8 13.7 21 6 21 305 -13.9 0 -13.7 -14.3 12/06/2005 14:50:00 18.7 2.4 23.7 12.2 18.5 2.4 24 12.2 22 5 28 305 -13.8 0 -13.3 -14.1 12/06/2005 15:00:00 18.3 2 23.3 14.1 17.9 2.1 22.9 12.2 22 7 17 305 -13.7 0.1 -13.3 -14.1 12/06/2005 15:10:00 20.5 2.2 25.6 14.9 19.8 2.2 25.2 14.9 24 6 25 305 -13.6 0 -13.3 -13.7 12/06/2005 15:20:00 20.2 2.6 26 14.5 19.6 2.6 25.6 14.5 24 6 14 305 -13.6 0 -13.3 -13.7 12/06/2005 15:30:00 19.3 2.5 24.8 13 18.7 2.4 24.8 13.3 26 6 25 305 -13.6 0.1 -13.1 -13.7 12/06/2005 15:40:00 20.5 2.1 26 15.3 20.1 2.1 26 15.3 28 6 25 305 -13.5 0.1 -13.1 -13.7 12/06/2005 15:50:00 20.9 2.1 26.8 14.5 20.4 2 26 14.9 28 6 22 305 -13.5 0.1 -13.1 -13.7 12/06/2005 16:00:00 20.1 2.4 25.2 14.9 19.6 2.2 24.8 14.9 24 6 23 305 -13.5 0.1 -13.1 -13.7 12/06/2005 16:10:00 19.2 2 24 13.7 18.8 2 22.9 14.1 26 6 29 305 -13.5 0.1 -13.1 -13.7 12/06/2005 16:20:00 19.8 2 24 15.3 19.4 2 24 13.7 24 6 25 305 -13.5 0.1 -13.1 -13.7 12/06/2005 16:30:00 20.4 2.1 24.8 15.3 19.9 2.1 23.7 14.1 27 5 18 305 -13.5 0.1 -13.1 -13.7 12/06/2005 16:40:00 20.4 2.3 25.2 14.5 19.9 2.3 24.8 14.5 26 6 33 305 -13.5 0.1 -13.1 -13.7 12/06/2005 16:50:00 20 2.2 25.2 14.9 19.4 2.2 24 13.7 27 5 29 305 -13.4 0.1 -12.9 -13.5 12/06/2005 17:00:00 21.7 1.7 26.3 17.6 21.2 1.7 26.3 17.6 28 5 26 305 -13.5 0.1 -13.1 -13.7 12/06/2005 17:10:00 20 2.4 25.2 14.9 19.5 2.3 24.4 14.1 27 6 21 305 -13.4 0 -12.9 -13.7 12/06/2005 17:20:00 21.3 2.3 25.6 15.3 20.7 2.2 25.2 14.5 26 6 21 305 -13.3 0 -12.9 -13.5 12/06/2005 17:30:00 21.4 2.1 26 16.1 21 2.2 26 15.6 27 5 26 305 -13.2 0 -12.9 -13.3 12/06/2005 17:40:00 21.5 2 26 16.1 21 2 26 16.1 26 5 36 305 -13.2 0 -12.9 -13.3 12/06/2005 17:50:00 20.2 2.7 26 14.1 19.8 2.5 26 13.7 28 6 36 305 -13.2 0.1 -12.7 -13.3 12/06/2005 18:00:00 21.9 2.3 27.5 17.2 21.4 2.4 27.1 14.9 31 6 34 305 -13.2 0.1 -12.5 -13.5 12/06/2005 18:10:00 22.3 2.3 26.8 16.4 21.7 2.3 26.8 15.6 30 6 29 305 -13.2 0.1 -12.9 -13.5 12/06/2005 18:20:00 21 2.3 27.1 15.6 20.6 2.4 26 14.5 30 6 22 305 -13.2 0.1 -12.9 -13.5 12/06/2005 18:30:00 20.6 2.1 26.3 15.6 20 2.1 26.8 14.9 30 6 30 305 -13.3 0 -12.9 -13.5 12/06/2005 18:40:00 19.8 2.6 26 13.3 19.4 2.6 25.2 13.3 30 6 34 305 -13.3 0 -12.9 -13.5 12/06/2005 18:50:00 20.9 2.4 25.6 14.5 20.4 2.3 25.2 14.1 29 6 20 305 -13.3 0.1 -12.9 -13.5 12/06/2005 19:00:00 20.4 1.9 25.2 15.3 20 1.9 24 15.3 27 6 22 305 -13.3 0 -12.9 -13.5 12/06/2005 19:10:00 20.6 2.1 24.4 15.3 20.1 2 24.8 14.5 27 6 38 305 -13.3 0.1 -12.9 -13.5 12/06/2005 19:20:00 20.9 1.8 25.2 16.4 20.5 1.7 24.4 16.1 27 5 25 305 -13.4 0 -12.9 -13.5 12/06/2005 19:30:00 21.2 2.3 25.6 16.1 20.7 2.2 25.6 14.9 26 6 22 305 -13.4 0.1 -12.9 -13.7 12/06/2005 19:40:00 21.3 1.8 24.8 16.1 20.7 1.8 24.4 15.6 27 6 33 305 -13.3 0.1 -12.9 -13.5 12/06/2005 19:50:00 21.3 2.5 26.3 14.9 20.7 2.4 25.6 14.5 25 5 26 305 -13.4 0.1 -12.9 -13.5 12/06/2005 20:00:00 20.3 2.2 24.8 14.5 19.7 2.1 24.4 14.5 26 6 27 305 -13.3 0.1 -12.9 -13.5 12/06/2005 20:10:00 18.9 2.3 24 13 18.4 2.3 23.3 13 28 6 30 305 -13.2 0.1 -12.9 -13.5 12/06/2005 20:20:00 20.8 2.2 26.3 16.1 20.4 2.1 25.2 16.1 27 6 33 305 -13.2 0.1 -12.9 -13.5 12/06/2005 20:30:00 19.2 2.4 24.4 14.1 18.7 2.3 24.8 13.7 29 6 33 305 -13.2 0.1 -12.9 -13.5 12/06/2005 20:40:00 18.7 2.4 24.8 13.7 18.3 2.3 23.3 13.3 28 6 22 305 -13.3 0.1 -12.9 -13.5 12/06/2005 20:50:00 21.3 2.2 26 15.6 20.8 2.2 25.6 15.6 27 5 22 305 -13.4 0.1 -12.9 -13.5 12/06/2005 21:00:00 20.9 1.9 24.4 15.3 20.4 2 24.8 14.5 27 5 24 305 -13.4 0.1 -13.1 -13.7 12/06/2005 21:10:00 20.4 1.7 24.8 16.4 19.9 1.7 24.8 14.9 28 5 28 305 -13.3 0 -12.9 -13.5 12/06/2005 21:20:00 20 2.3 24.8 14.5 19.4 2.1 24 14.9 27 6 27 305 -13.1 0.1 -12.5 -13.3 12/06/2005 21:30:00 19.7 2.1 24.4 14.5 19.4 2.2 23.7 13.3 29 6 26 305 -13 0 -12.5 -13.3 12/06/2005 21:40:00 18.9 2.2 24.4 13 18.5 2.1 23.3 13 29 6 32 305 -13.2 0.1 -12.7 -13.5 12/06/2005 21:50:00 20.1 2.1 24 14.1 19.6 2.2 23.3 13 30 5 33 305 -13.3 0 -12.9 -13.5 12/06/2005 22:00:00 18.6 1.7 22.9 14.1 18.4 1.9 22.9 13.7 29 6 29 305 -13.2 0.1 -12.7 -13.3 12/06/2005 22:10:00 19.9 2.2 24.4 14.1 19.6 2.2 24.8 14.5 27 6 27 305 -13.1 0.1 -12.5 -13.3 12/06/2005 22:20:00 18.9 2.5 24.4 13.7 18.5 2.4 24.4 13.3 28 6 30 305 -13.3 0.2 -12.7 -13.7 12/06/2005 22:30:00 20.2 1.8 24.8 15.3 19.7 1.7 25.2 14.9 31 6 29 305 -13.5 0.1 -13.1 -13.7 12/06/2005 22:40:00 19.7 1.9 24.4 14.9 19.3 2 24 14.5 29 6 31 305 -13.6 0.1 -13.1 -13.7 12/06/2005 22:50:00 18.3 2.5 23.7 12.2 17.9 2.4 22.9 13 28 6 30 305 -13.5 0.1 -13.1 -13.7 12/06/2005 23:00:00 19.6 1.8 24 14.5 19.2 1.9 23.7 14.1 27 6 19 305 -13.6 0 -13.1 -13.7 12/06/2005 23:10:00 19.6 1.9 24.8 15.3 19.1 1.8 24.4 14.5 27 6 26 305 -13.6 0 -13.1 -13.7 12/06/2005 23:20:00 20.3 2 26.3 15.6 19.7 1.9 24.8 15.6 27 5 27 305 -13.6 0 -13.3 -13.7 12/06/2005 23:30:00 18.5 2 24.4 13.7 18 1.9 24 13 30 5 31 305 -13.6 0.1 -13.1 -13.7 12/06/2005 23:40:00 17.9 1.7 22.1 13 17.5 1.7 22.1 11.8 32 6 30 305 -13.6 0 -13.3 -13.7 12/06/2005 23:50:00 19.5 2 24.4 14.9 19.2 1.9 24.4 14.5 31 6 32 305 -13.7 0 -13.3 -13.7 12/07/2005 00:00:00 19.8 1.8 24.4 15.6 19.3 1.7 24 15.3 29 5 21 305 -13.7 0 -13.3 -13.7 12/07/2005 00:10:00 19.2 1.9 24.8 14.9 18.8 1.8 23.3 14.5 30 6 19 305 -13.6 0 -13.3 -13.7 12/07/2005 00:20:00 19.2 2.5 24.8 13.3 18.8 2.5 24.4 13.3 33 6 32 305 -13.6 0 -13.3 -13.7 12/07/2005 00:30:00 21 1.7 24.8 17.2 20.5 1.7 24.4 16.1 31 5 36 305 -13.7 0 -13.3 -13.9 12/07/2005 00:40:00 19.2 2.3 24.8 13.7 18.6 2.3 24.8 13.3 26 5 27 305 -13.7 0 -13.3 -13.9 12/07/2005 00:50:00 19.9 1.7 24.4 15.6 19.5 1.7 24.4 14.9 29 6 30 305 -13.7 0.1 -13.3 -13.9 12/07/2005 01:00:00 18.9 2.1 24 14.1 18.5 2 22.9 13.7 30 5 27 305 -13.6 0 -13.1 -13.7 12/07/2005 01:10:00 19.8 1.7 23.7 14.1 19.3 1.6 23.7 14.1 31 5 32 305 -13.6 0 -13.3 -13.7 12/07/2005 01:20:00 20.4 1.8 24.8 14.9 20 1.9 24.8 14.9 34 6 37 305 -13.6 0 -13.3 -13.7 12/07/2005 01:30:00 18.9 2.1 24 13.3 18.4 2.1 24 13.3 32 5 32 305 -13.5 0.1 -13.1 -13.7 12/07/2005 01:40:00 19.7 2.3 25.2 14.5 19.3 2.2 24.4 14.1 32 5 27 305 -13.5 0.1 -13.1 -13.7 12/07/2005 01:50:00 20.1 2.2 24.4 14.1 19.4 2.1 24.8 14.5 32 6 39 305 -13.5 0.1 -13.1 -13.7 12/07/2005 02:00:00 20.1 2 24.8 13.3 19.4 2 23.7 13.3 31 5 35 305 -13.7 0 -13.3 -13.9 12/07/2005 02:10:00 19.2 2.2 23.7 13.7 18.8 2.1 23.3 14.1 30 5 23 305 -13.7 0 -13.3 -13.7 12/07/2005 02:20:00 20.7 1.9 24.8 14.5 20.1 1.9 24.4 15.3 31 5 34 305 -13.7 0 -13.3 -13.7 12/07/2005 02:30:00 20.3 2.2 24.8 14.5 19.6 2.2 24.8 14.5 29 5 36 305 -13.7 0 -13.3 -13.9 12/07/2005 02:40:00 19.7 1.9 24 14.5 19.2 2 23.3 13.3 31 5 30 305 -13.7 0 -13.3 -13.7 12/07/2005 02:50:00 18.5 2 22.6 13 18 2 22.1 13 29 6 28 305 -13.6 0 -13.3 -13.7 12/07/2005 03:00:00 19.1 2.1 24.4 14.1 18.6 2.2 23.7 13.7 29 5 29 305 -13.8 0 -13.3 -13.9 12/07/2005 03:10:00 19.3 1.9 23.7 14.1 18.7 1.8 23.3 14.5 27 6 28 305 -13.7 0 -13.3 -13.9 12/07/2005 03:20:00 20.6 2 24.8 15.3 20 2 24.4 14.1 28 5 27 305 -13.7 0 -13.3 -13.9 12/07/2005 03:30:00 20.6 1.7 24 16.4 19.9 1.7 23.7 15.6 29 5 35 305 -13.6 0 -13.5 -13.7 12/07/2005 03:40:00 19.4 2.7 25.6 13.3 19 2.6 25.2 14.1 31 5 36 305 -13.6 0 -13.3 -13.7 12/07/2005 03:50:00 20.4 2.1 25.2 13.3 19.9 2.1 24.8 15.3 31 5 30 305 -13.6 0 -13.3 -13.7 12/07/2005 04:00:00 20.6 2.2 24.4 13.7 20.1 2.2 24.8 13.3 33 6 39 305 -13.5 0.1 -13.1 -13.7 12/07/2005 04:10:00 19.7 2.3 26 14.1 19.3 2.4 25.2 13.7 34 6 28 305 -13.5 0 -13.1 -13.7 12/07/2005 04:20:00 18.8 2.2 23.7 14.1 18.4 2.1 24.4 13.3 30 6 24 305 -13.3 0.1 -12.9 -13.5 12/07/2005 04:30:00 20.3 2 24.8 15.3 19.7 2 23.7 14.5 28 5 36 305 -13.4 0.1 -12.9 -13.7 12/07/2005 04:40:00 17.3 2.3 24.8 12.6 17 2.2 24.8 12.6 20 6 32 305 -14 0.4 -13.1 -14.6 12/07/2005 04:50:00 17.6 2 22.9 11.5 17.3 2.1 23.3 12.6 22 6 18 305 -14.3 0.1 -13.9 -14.6 12/07/2005 05:00:00 18.3 2 22.6 13.3 17.8 2.1 23.7 13 26 6 21 305 -13.8 0.2 -13.3 -14.3 12/07/2005 05:10:00 19.3 2.1 23.3 12.6 18.8 2 22.9 13.7 28 5 30 305 -13.5 0.1 -13.1 -13.7 12/07/2005 05:20:00 18.7 2.3 24 13 18.3 2.1 23.3 12.6 30 6 27 305 -13.5 0.1 -13.1 -13.7 12/07/2005 05:30:00 21 1.9 25.2 16.4 20.4 1.9 24.4 15.3 28 5 27 305 -13.5 0.1 -13.1 -13.7 12/07/2005 05:40:00 20.2 2.3 24.4 14.9 19.6 2.2 24.8 14.1 26 6 31 305 -13.5 0.1 -13.1 -13.7 12/07/2005 05:50:00 19.2 2.2 24 13.3 18.8 2.1 24 13.3 24 6 21 305 -13.6 0 -13.3 -13.7 12/07/2005 06:00:00 21.4 2.2 26 15.3 20.7 2.1 26.8 15.6 27 6 17 305 -13.6 0.1 -13.1 -13.7 12/07/2005 06:10:00 19.8 2.2 24.4 14.5 19.3 2.2 23.7 13.3 28 6 26 305 -13.6 0.1 -13.3 -13.7 12/07/2005 06:20:00 20.4 2.2 24.4 14.9 19.8 2.1 24.8 14.1 29 5 29 305 -13.6 0.1 -13.1 -13.7 12/07/2005 06:30:00 20.6 2.4 26 14.5 20 2.4 25.2 13.7 30 6 33 305 -13.5 0.1 -13.1 -13.7 12/07/2005 06:40:00 21.8 2.3 27.5 15.6 21.2 2.2 25.6 16.1 29 6 31 305 -13.6 0 -13.3 -13.7 12/07/2005 06:50:00 21.4 2.4 26.3 15.6 20.8 2.3 25.6 15.6 29 6 21 305 -13.6 0 -13.3 -13.7 12/07/2005 07:00:00 21.1 2.2 26.3 14.5 20.5 2.2 26.3 14.1 30 6 30 305 -13.6 0 -13.3 -13.7 12/07/2005 07:10:00 20.5 2.1 25.2 15.6 20.1 2 25.2 15.3 30 6 25 305 -13.6 0 -13.3 -13.7 12/07/2005 07:20:00 20.7 2.1 25.2 16.4 20.4 2 24.8 15.3 28 6 28 305 -13.6 0 -13.5 -13.7 12/07/2005 07:30:00 20.1 2.3 26 13 19.8 2.3 25.2 14.1 27 7 32 305 -13.6 0 -13.3 -13.7 12/07/2005 07:40:00 21.2 2.4 27.1 15.3 20.7 2.3 26 14.9 29 6 29 305 -13.6 0 -13.3 -13.7 12/07/2005 07:50:00 20.9 2.2 27.1 15.6 20.4 2.1 26 15.3 30 6 35 305 -13.6 0 -13.5 -13.7 12/07/2005 08:00:00 20.3 2.2 25.2 14.5 20 2.2 25.2 14.9 31 6 36 305 -13.6 0 -13.3 -13.7 12/07/2005 08:10:00 20.3 2.3 26 14.5 19.6 2.3 26.3 14.1 32 7 32 305 -13.6 0 -13.1 -13.7 12/07/2005 08:20:00 21.6 2.1 27.1 16.1 21.2 2.2 27.5 15.3 33 6 29 305 -13.6 0 -13.3 -13.7 12/07/2005 08:30:00 21.5 2.2 27.1 15.6 21.2 2.2 26.8 15.3 32 6 33 305 -13.6 0 -13.3 -13.7 12/07/2005 08:40:00 21.9 2.3 27.1 14.1 21.4 2.3 26.8 14.9 28 6 37 305 -13.6 0 -13.3 -13.7 12/07/2005 08:50:00 21.7 2.2 27.5 16.1 21.1 2.2 26.8 16.4 28 6 25 305 -13.7 0 -13.3 -13.7 12/07/2005 09:00:00 21.7 2.1 26.8 16.4 21.2 2.1 26.3 16.8 27 6 25 305 -13.7 0 -13.3 -13.9 12/07/2005 09:10:00 21 2.5 26.8 15.6 20.5 2.4 26.3 14.9 27 6 30 305 -13.6 0 -13.3 -13.7 12/07/2005 09:20:00 20.1 2.3 25.6 14.5 19.7 2.2 26 14.9 26 6 27 305 -13.5 0.1 -13.1 -13.7 12/07/2005 09:30:00 21.3 2.4 26.3 15.3 20.8 2.2 25.2 15.3 23 6 21 305 -13.5 0.1 -13.1 -13.7 12/07/2005 09:40:00 20.9 2.5 27.1 15.3 20.5 2.5 26.3 14.5 23 6 22 305 -13.4 0.1 -13.1 -13.7 12/07/2005 09:50:00 20.8 2.6 26.8 13.7 20.3 2.5 26.8 14.1 26 6 21 305 -13.3 0.1 -12.9 -13.7 12/07/2005 10:00:00 20.9 2 25.6 15.3 20.4 2.1 25.6 14.9 26 6 32 305 -13.2 0.1 -12.9 -13.5 12/07/2005 10:10:00 22.1 2.2 27.1 17.2 21.6 2.1 26.8 16.1 28 6 12 305 -13.1 0.1 -12.9 -13.3 12/07/2005 10:20:00 21.3 2.4 27.1 15.6 20.7 2.5 26 14.1 28 6 19 305 -13.1 0 -12.7 -13.3 12/07/2005 10:30:00 21.5 2.1 26 15.3 21 2.1 25.2 15.3 28 6 26 305 -13.1 0 -12.7 -13.3 12/07/2005 10:40:00 19.7 2.7 26.3 14.5 19.4 2.7 26 13.7 28 6 27 305 -13.1 0 -12.9 -13.3 12/07/2005 10:50:00 19.7 2.5 26.8 14.1 19.2 2.3 26 13.7 25 6 25 305 -13.2 0.1 -12.9 -13.5 12/07/2005 11:00:00 20.5 2.4 26 14.1 20 2.3 26 14.1 22 5 18 305 -13.3 0.1 -12.9 -13.5 12/07/2005 11:10:00 19.2 2.3 24.4 13.3 18.8 2.3 24 13.3 26 6 29 305 -13.2 0 -12.9 -13.5 12/07/2005 11:20:00 21.7 2.2 27.1 15.6 21.2 2.3 26.3 15.3 28 6 25 305 -13.1 0 -12.9 -13.3 12/07/2005 11:30:00 21.6 2.3 26.8 15.3 21 2.2 26.3 14.1 27 6 22 305 -13.2 0 -12.9 -13.3 12/07/2005 11:40:00 21.2 2.5 27.5 15.3 20.8 2.3 27.5 15.6 26 6 27 305 -13.3 0 -13.1 -13.5 12/07/2005 11:50:00 22 2.3 26.3 15.3 21.4 2.2 26 15.3 27 6 31 305 -13.2 0 -13.1 -13.3 12/07/2005 12:00:00 21.1 2.5 27.1 14.9 20.5 2.5 26 14.5 27 6 33 305 -13.2 0 -13.1 -13.3 12/07/2005 12:10:00 21.1 2.6 26.8 15.3 20.6 2.5 26.8 14.5 26 6 15 305 -13.3 0 -12.9 -13.5 12/07/2005 12:20:00 22.8 2.5 28.3 16.4 22.3 2.4 27.5 16.8 26 5 30 305 -13.3 0 -13.1 -13.5 12/07/2005 12:30:00 21.8 2.5 26.8 15.6 21.3 2.4 27.1 15.3 26 5 35 305 -13.3 0 -13.1 -13.3 12/07/2005 12:40:00 22.9 2.4 28.3 15.3 22.2 2.3 27.5 17.2 25 5 19 305 -13.2 0 -12.9 -13.3 12/07/2005 12:50:00 22.3 2.3 27.1 16.4 21.6 2.4 26.8 15.6 25 6 31 305 -13.1 0 -12.9 -13.3 12/07/2005 13:00:00 21.6 2.6 27.5 14.9 21.1 2.5 26.8 15.3 26 6 27 305 -13.1 0 -12.9 -13.3 12/07/2005 13:10:00 20.4 2 24.8 15.6 20 2 24.4 14.5 25 6 31 305 -13.1 0 -12.9 -13.3 12/07/2005 13:20:00 21.9 2.5 27.5 16.1 21.6 2.4 27.1 15.6 25 6 30 305 -13.1 0 -12.9 -13.3 12/07/2005 13:30:00 21.4 2.5 27.9 15.3 21 2.4 27.1 14.9 26 6 29 305 -13.1 0.1 -12.7 -13.3 12/07/2005 13:40:00 22.3 2.6 27.9 15.3 21.8 2.6 27.9 14.1 26 6 27 305 -13.2 0.1 -12.9 -13.3 12/07/2005 13:50:00 22.4 2.4 28.3 16.1 22 2.4 27.9 16.4 27 6 31 305 -13.2 0.1 -12.7 -13.3 12/07/2005 14:00:00 21.5 2.2 26.8 16.4 21.2 2.2 26.8 15.3 26 6 26 305 -13.2 0.1 -12.9 -13.5 12/07/2005 14:10:00 20.1 2.5 25.6 13.7 19.7 2.4 25.6 13.3 24 6 27 305 -13.2 0.1 -12.9 -13.3 12/07/2005 14:20:00 21.1 2.4 26.8 15.3 20.5 2.3 26.3 14.5 25 6 28 305 -13.1 0.1 -12.7 -13.3 12/07/2005 14:30:00 23.1 2.2 27.5 17.2 22.6 2.3 27.5 17.6 26 6 23 305 -13.1 0 -12.7 -13.3 12/07/2005 14:40:00 22.2 2.7 28.3 14.9 21.7 2.6 28.3 15.6 25 6 25 305 -13 0.1 -12.5 -13.3 12/07/2005 14:50:00 21.7 2.5 27.9 14.5 21 2.6 27.5 15.3 25 6 22 305 -13.1 0.1 -12.7 -13.3 12/07/2005 15:00:00 21.7 2.1 27.1 16.4 21.2 1.9 26 16.1 25 6 27 305 -13.1 0.1 -12.9 -13.3 12/07/2005 15:10:00 22.5 2.3 27.1 16.1 22 2.3 27.1 16.4 25 6 28 305 -13.1 0 -12.7 -13.3 12/07/2005 15:20:00 21.2 2.4 27.5 16.1 21 2.4 26.8 16.4 22 6 26 305 -13.1 0 -12.7 -13.3 12/07/2005 15:30:00 21.7 2.4 27.9 16.1 21.4 2.4 27.5 15.6 23 6 24 305 -13.2 0.1 -12.9 -13.3 12/07/2005 15:40:00 23.1 2.7 29.1 17.2 22.4 2.5 28.3 17.2 22 7 22 305 -13.3 0.1 -12.7 -13.5 12/07/2005 15:50:00 22.5 2.6 29.4 15.6 22.1 2.5 27.9 16.1 23 6 25 305 -13.3 0 -13.1 -13.5 12/07/2005 16:00:00 22.1 2.6 27.9 15.6 21.4 2.5 27.1 14.9 22 6 21 305 -13.3 0 -12.9 -13.5 12/07/2005 16:10:00 20.3 2.7 26.8 13.7 19.9 2.5 26.3 13.7 21 6 24 305 -13.3 0 -12.9 -13.5 12/07/2005 16:20:00 21.8 2.9 28.7 13.7 21.3 2.9 28.3 13.7 22 6 21 305 -13.2 0 -13.1 -13.5 12/07/2005 16:30:00 21.4 2.5 27.1 14.5 20.9 2.4 26.8 14.9 23 6 20 305 -13.3 0 -13.1 -13.5 12/07/2005 16:40:00 22.5 2.5 27.5 15.3 22 2.5 28.3 14.5 22 6 24 305 -13.4 0 -13.1 -13.5 12/07/2005 16:50:00 22.9 2.6 28.7 16.4 22.3 2.4 27.9 16.4 22 6 30 305 -13.4 0 -13.1 -13.5 12/07/2005 17:00:00 22.7 2.5 29.1 16.1 22.2 2.5 27.9 14.9 22 6 19 305 -13.3 0 -12.9 -13.5 12/07/2005 17:10:00 20.9 2.8 27.5 13.3 20.5 2.8 26.8 13.7 22 6 23 305 -13.2 0 -12.9 -13.3 12/07/2005 17:20:00 21.1 2.4 27.5 13.3 20.8 2.4 26 12.6 20 6 27 305 -13.2 0 -12.9 -13.3 12/07/2005 17:30:00 21.2 3.1 27.5 12.2 20.7 2.9 27.1 12.2 22 6 18 305 -13.2 0 -12.7 -13.5 12/07/2005 17:40:00 19.9 2.6 25.6 13 19.5 2.6 25.2 12.6 22 6 24 305 -13 0 -12.5 -13.1 12/07/2005 17:50:00 21.2 2.5 27.9 15.6 20.8 2.4 28.3 14.9 21 7 24 305 -13.2 0 -12.9 -13.3 12/07/2005 18:00:00 20.3 2.6 27.5 14.9 19.9 2.7 27.9 14.1 24 6 22 305 -13.1 0 -12.9 -13.3 12/07/2005 18:10:00 21 2.6 27.5 14.5 20.4 2.5 27.9 14.5 22 6 18 305 -13.2 0.1 -12.9 -13.5 12/07/2005 18:20:00 21.4 2.8 29.1 14.9 21.1 2.6 28.7 16.1 23 6 21 305 -13.1 0 -12.7 -13.3 12/07/2005 18:30:00 21.5 2 27.1 14.9 21 2 26 15.6 24 6 29 305 -13.1 0.1 -12.5 -13.3 12/07/2005 18:40:00 21.5 2.4 27.5 15.6 21 2.4 27.5 16.1 22 6 12 305 -13 0.1 -12.5 -13.3 12/07/2005 18:50:00 18.9 2.7 25.6 13.3 18.7 2.7 25.2 12.6 23 6 24 305 -12.9 0.1 -12.5 -13.1 12/07/2005 19:00:00 22 2.6 28.3 13.3 21.3 2.7 27.9 13.3 20 7 17 305 -12.9 0.1 -12.5 -13.3 12/07/2005 19:10:00 21.9 2.5 27.5 15.3 21.3 2.3 26.8 16.1 20 6 23 305 -13 0.1 -12.5 -13.3 12/07/2005 19:20:00 21.2 2.6 27.5 14.9 20.8 2.5 27.1 14.1 21 6 22 305 -12.9 0.1 -12.5 -13.1 12/07/2005 19:30:00 20.3 2.9 26.8 14.1 19.8 2.7 27.1 13.7 20 6 13 305 -12.9 0.1 -12.5 -13.1 12/07/2005 19:40:00 22.1 2.5 27.5 15.3 21.6 2.4 27.5 15.3 20 6 21 305 -12.8 0.1 -12.5 -13.1 12/07/2005 19:50:00 19.1 3.1 27.5 13 18.7 3.1 27.5 12.6 18 6 18 305 -12.8 0.1 -12.5 -12.9 12/07/2005 20:00:00 21.4 2.5 27.1 15.6 20.9 2.5 26.8 14.9 17 6 17 305 -12.9 0.1 -12.5 -13.1 12/07/2005 20:10:00 19.3 2.5 26 13 19.1 2.3 25.6 13.7 19 8 15 305 -12.9 0.1 -12.5 -13.1 12/07/2005 20:20:00 19.1 2.5 24.4 13.7 18.8 2.4 23.7 13.7 22 7 22 305 -12.9 0.1 -12.5 -13.1 12/07/2005 20:30:00 18.6 2.4 24 12.2 18.5 2.4 23.7 12.6 26 6 22 305 -12.9 0.1 -12.5 -13.1 12/07/2005 20:40:00 18.3 2.1 23.3 13.3 17.9 2 22.9 12.6 27 6 24 305 -12.9 0.1 -12.5 -13.1 12/07/2005 20:50:00 19.6 2.2 25.2 13.7 19.2 2.2 24.4 13.7 24 6 18 305 -12.7 0 -12.3 -12.9 12/07/2005 21:00:00 19.8 2.6 24.8 13.3 19.5 2.5 24.8 13.7 21 6 13 305 -12.6 0 -12.3 -12.9 12/07/2005 21:10:00 20 2.4 24.8 13.3 19.5 2.3 24.8 12.6 16 6 13 305 -12.7 0 -12.5 -12.9 12/07/2005 21:20:00 19.3 2.4 26 14.1 19 2.5 24.8 14.1 15 5 22 305 -12.9 0 -12.5 -12.9 12/07/2005 21:30:00 19.4 2.8 26.8 12.6 19.1 2.7 27.5 12.6 19 6 15 305 -12.7 0 -12.5 -12.9 12/07/2005 21:40:00 18.2 2.6 24.4 12.2 18 2.5 24.4 11.8 20 7 13 305 -12.7 0 -12.5 -12.9 12/07/2005 21:50:00 17.7 2.5 23.3 13 17.4 2.4 23.7 12.2 21 6 22 305 -12.8 0 -12.5 -13.1 12/07/2005 22:00:00 18.7 2.5 25.6 13 18.4 2.5 24.8 12.6 21 7 19 305 -12.8 0.1 -12.5 -12.9 12/07/2005 22:10:00 18.2 2.3 23.7 13 18 2.2 23.7 12.6 21 6 9 305 -12.9 0 -12.5 -13.1 12/07/2005 22:20:00 19.9 2.3 27.1 14.5 19.5 2.4 26 14.1 22 6 14 305 -12.8 0 -12.5 -13.1 12/07/2005 22:30:00 17.6 1.9 22.9 12.6 17.3 2 23.3 11.8 23 6 20 305 -13 0.1 -12.5 -13.1 12/07/2005 22:40:00 18.1 2.3 24 13.7 17.8 2.2 24 12.6 22 5 16 305 -12.8 0.1 -12.3 -13.1 12/07/2005 22:50:00 19.2 1.7 24 14.9 19 1.7 23.7 14.5 19 6 16 305 -12.7 0.1 -12.3 -12.9 12/07/2005 23:00:00 19.2 2.3 24.8 14.1 18.8 2.3 24.8 14.5 19 7 19 305 -12.8 0.1 -12.5 -12.9 12/07/2005 23:10:00 17.1 2 21.4 12.2 16.9 2 21.8 10.7 12 8 31 305 -13.2 0.4 -12.5 -14.3 12/07/2005 23:20:00 17.1 2 22.6 12.2 17 2 21.4 12.6 8 6 4 305 -14.2 0.1 -13.7 -14.4 12/07/2005 23:30:00 16.6 1.8 21.4 12.6 16.4 1.7 21 11.8 9 6 8 305 -14.2 0 -13.7 -14.4 12/07/2005 23:40:00 16.4 2 22.1 11.5 16.4 2.1 21.4 11.5 7 6 5 305 -14.3 0.1 -13.9 -14.6 12/07/2005 23:50:00 15.8 1.8 19.9 9.9 15.6 1.8 19.5 11.1 8 5 7 305 -14.3 0 -14.1 -14.6 12/08/2005 00:00:00 15.4 1.6 19.5 11.1 15.3 1.7 19.5 11.1 9 6 6 305 -14.2 0 -13.7 -14.4 12/08/2005 00:10:00 14.8 1.9 19.5 9.5 14.7 1.9 19.5 9.9 18 8 22 305 -13.6 0.4 -12.7 -14.3 12/08/2005 00:20:00 17.5 2.3 23.3 11.8 17.1 2.3 22.9 11.8 23 6 33 305 -13.2 0 -12.7 -13.3 12/08/2005 00:30:00 17.8 2.4 23.7 11.8 17.4 2.3 23.7 11.8 24 6 15 305 -13.1 0 -12.7 -13.5 12/08/2005 00:40:00 17.4 2.6 22.9 11.1 17.2 2.5 22.6 11.5 21 6 20 305 -13.1 0.1 -12.5 -13.5 12/08/2005 00:50:00 18.6 1.7 23.3 12.2 18.4 1.7 22.6 13 8 9 22 305 -13.9 0.7 -12.7 -14.8 12/08/2005 01:00:00 17.2 1.9 22.1 13 17.1 2 22.6 12.2 7 6 4 305 -14.8 0 -14.6 -15 12/08/2005 01:10:00 16.1 2.1 21.8 11.5 16 2 21 11.1 9 6 4 305 -14.9 0 -14.6 -15 12/08/2005 01:20:00 17.2 2 22.1 11.5 16.9 2 22.1 10.7 7 6 1 305 -15 0.1 -14.6 -15.2 12/08/2005 01:30:00 16.4 1.7 21 12.2 16.2 1.8 20.6 12.2 7 6 9 305 -14.7 0 -14.4 -14.8 12/08/2005 01:40:00 15.8 1.8 20.2 11.5 15.5 1.9 20.2 11.5 9 6 4 305 -14.4 0.1 -14.1 -14.6 12/08/2005 01:50:00 15.6 1.7 20.6 11.5 15.5 1.7 19.9 11.8 8 6 9 305 -14.2 0 -13.9 -14.4 12/08/2005 02:00:00 15.5 2.1 21.4 10.7 15.3 2 21 11.1 7 6 9 305 -14.4 0.2 -13.9 -14.8 12/08/2005 02:10:00 17.7 1.7 21.8 13.3 17.5 1.7 21 13.3 5 5 4 305 -15 0.2 -14.4 -15.2 12/08/2005 02:20:00 16.4 1.7 20.6 11.5 16.3 1.7 20.6 11.8 7 6 356 305 -15.2 0 -14.8 -15.4 12/08/2005 02:30:00 16.8 2 21.4 11.8 16.8 2 21.8 12.6 5 6 3 305 -15.3 0 -15 -15.6 12/08/2005 02:40:00 16.6 2.2 22.1 11.5 16.5 2.1 21.8 11.8 7 6 3 305 -15.1 0.1 -14.8 -15.2 12/08/2005 02:50:00 16.6 2.3 22.1 12.2 16.4 2.2 22.6 12.2 7 6 4 305 -15 0 -14.6 -15.2 12/08/2005 03:00:00 16.7 2 21.8 11.8 16.6 2 21 12.6 10 6 9 305 -15.1 0 -14.6 -15.2 12/08/2005 03:10:00 17 1.9 21.4 11.5 16.8 1.8 21.4 11.1 8 6 3 305 -15.2 0 -14.8 -15.2 12/08/2005 03:20:00 18.4 2.2 23.3 13 17.9 2.2 22.1 11.5 8 6 7 305 -15.3 0 -15 -15.6 12/08/2005 03:30:00 17.1 2.1 22.6 12.6 16.8 2.2 23.3 11.1 7 6 3 305 -15.1 0.1 -14.8 -15.2 12/08/2005 03:40:00 17.5 2.1 22.1 11.1 17.3 2 21.8 11.1 9 6 8 305 -15.2 0.1 -14.8 -15.2 12/08/2005 03:50:00 16 1.9 21 10.7 16 1.9 21 11.1 9 6 8 305 -15.1 0.1 -14.6 -15.2 12/08/2005 04:00:00 16.4 2.1 21.4 11.5 16.2 2 20.6 10.7 9 6 4 305 -15.1 0.1 -14.8 -15.2 12/08/2005 04:10:00 15.6 2.4 22.9 11.1 15.3 2.4 21 11.1 8 7 13 305 -15.1 0 -14.6 -15.2 12/08/2005 04:20:00 16.6 2.2 22.1 11.5 16.4 2.2 21.8 10.7 7 6 0 305 -15.2 0 -14.8 -15.6 12/08/2005 04:30:00 18.2 2 22.6 10.7 17.9 2 22.1 10.3 7 6 1 305 -15.5 0 -15.2 -15.6 12/08/2005 04:40:00 16.9 1.9 22.1 12.6 16.8 1.9 21.8 11.5 8 6 1 305 -15.5 0 -15 -15.6 12/08/2005 04:50:00 16.8 1.8 21.8 11.5 16.6 1.8 22.1 11.5 7 6 3 305 -15.4 0 -15 -15.6 12/08/2005 05:00:00 16.2 2.1 22.1 10.7 16.1 2 22.1 11.1 9 6 4 305 -15.2 0 -14.8 -15.4 12/08/2005 05:10:00 17.8 1.8 22.1 12.2 17.6 1.9 22.1 11.8 11 5 14 305 -15.2 0 -14.8 -15.4 12/08/2005 05:20:00 17.8 2 23.3 12.6 17.5 2 22.9 12.6 8 6 4 305 -15.4 0 -15 -15.6 12/08/2005 05:30:00 16.5 2.1 20.6 11.5 16.4 2.1 21 11.5 9 6 16 305 -15.4 0 -15 -15.6 12/08/2005 05:40:00 15.1 2 20.6 10.7 15 1.9 19.5 10.3 9 6 7 305 -15.2 0.1 -14.8 -15.2 12/08/2005 05:50:00 15.2 1.7 19.5 10.3 15.1 1.8 19.5 10.3 10 6 11 305 -15.2 0 -14.8 -15.2 12/08/2005 06:00:00 13.6 1.9 19.5 9.5 13.5 1.9 18.3 9.1 6 6 8 305 -15.2 0 -14.8 -15.4 12/08/2005 06:10:00 15 1.7 18.7 11.1 15 1.7 19.1 9.9 8 6 6 305 -15.1 0.1 -14.6 -15.2 12/08/2005 06:20:00 16.2 2.3 21.4 9.9 16 2.2 21 9.9 9 5 12 305 -15.1 0.1 -14.6 -15.4 12/08/2005 06:30:00 15.5 2.1 20.2 10.7 15.5 2.1 21 10.3 6 6 7 305 -15.3 0 -15 -15.6 12/08/2005 06:40:00 16.1 2.3 22.1 12.2 16 2.3 22.1 11.8 6 6 8 305 -15.4 0.1 -15 -15.6 12/08/2005 06:50:00 14.4 1.9 18.7 9.9 14.3 1.8 18.7 9.5 9 6 2 305 -15.4 0.1 -15 -15.6 12/08/2005 07:00:00 16.1 2.2 21 10.3 15.8 2.2 20.6 9.9 9 6 5 305 -15.2 0 -14.8 -15.2 12/08/2005 07:10:00 15.6 1.8 20.2 10.7 15.6 1.8 19.5 10.7 9 5 9 305 -15.1 0.1 -14.6 -15.2 12/08/2005 07:20:00 16 2.4 21 10.3 15.7 2.3 20.6 10.3 9 6 7 305 -15 0 -14.6 -15 12/08/2005 07:30:00 16.6 1.7 22.1 12.6 16.4 1.7 21.4 11.5 9 6 5 305 -15 0 -14.6 -15 12/08/2005 07:40:00 15.5 1.7 19.5 11.5 15.4 1.6 19.5 11.5 7 6 11 305 -15 0.1 -14.6 -15.2 12/08/2005 07:50:00 15.9 2.2 20.6 11.1 15.7 2.1 21 10.3 8 6 9 305 -15.2 0 -14.8 -15.4 12/08/2005 08:00:00 15.4 2.2 20.6 10.7 15.3 2.1 20.6 10.7 7 6 7 305 -15.3 0 -15 -15.4 12/08/2005 08:10:00 15.8 2 20.2 10.7 15.7 1.9 19.9 9.9 7 6 4 305 -15.3 0 -15 -15.6 12/08/2005 08:20:00 15.6 1.9 20.2 11.5 15.5 2 20.2 10.7 8 6 7 305 -15.3 0 -15 -15.6 12/08/2005 08:30:00 15.9 2 21.4 11.5 15.7 2 21.4 11.5 6 6 2 305 -15.3 0 -15 -15.6 12/08/2005 08:40:00 15.4 2.1 19.9 10.7 15.3 2.1 20.2 10.3 7 6 3 305 -15.3 0 -15 -15.4 12/08/2005 08:50:00 15.3 2 19.9 9.9 15.1 2 19.5 10.3 7 6 8 305 -15.3 0 -15 -15.4 12/08/2005 09:00:00 14.5 2.4 20.6 8.8 14.5 2.3 20.2 9.5 8 6 6 305 -15.2 0.1 -14.8 -15.2 12/08/2005 09:10:00 15.9 1.9 20.2 10.3 15.8 2 20.2 11.1 6 6 10 305 -15.2 0 -14.8 -15.2 12/08/2005 09:20:00 15.9 1.7 20.6 11.1 15.8 1.7 19.5 10.7 6 6 1 305 -15.2 0 -14.8 -15.2 12/08/2005 09:30:00 14.7 1.7 19.5 11.1 14.5 1.7 19.1 9.9 6 5 6 305 -15.1 0.1 -14.6 -15.2 12/08/2005 09:40:00 14.3 1.9 18.7 8.8 14.3 1.7 17.9 9.1 7 6 5 305 -15 0.1 -14.6 -15 12/08/2005 09:50:00 14 1.9 18.3 9.5 13.8 1.9 18.7 9.9 8 6 8 305 -14.9 0 -14.6 -15 12/08/2005 10:00:00 14.5 1.9 19.5 10.7 14.3 1.8 19.1 9.9 8 6 5 305 -14.8 0 -14.6 -15 12/08/2005 10:10:00 14.1 1.8 18.7 9.1 14 1.8 18.3 9.1 10 6 8 305 -14.7 0 -14.4 -14.8 12/08/2005 10:20:00 14.6 1.7 19.1 10.7 14.4 1.7 19.1 10.7 8 5 11 305 -14.8 0 -14.4 -14.8 12/08/2005 10:30:00 15.3 1.6 19.5 11.5 15.2 1.6 20.2 10.7 7 6 7 305 -14.8 0 -14.6 -15 12/08/2005 10:40:00 15.7 1.7 20.2 11.8 15.6 1.7 19.9 11.8 7 5 7 305 -14.8 0 -14.4 -15 12/08/2005 10:50:00 14.6 2 19.1 9.9 14.4 1.8 18.3 9.5 7 6 5 305 -14.8 0 -14.6 -15 12/08/2005 11:00:00 15.3 1.8 18.7 10.3 15.3 1.7 18.7 10.3 6 5 9 305 -14.8 0 -14.4 -15 12/08/2005 11:10:00 15.7 1.6 19.5 10.7 15.5 1.7 18.7 10.3 4 5 3 305 -14.8 0 -14.4 -15 12/08/2005 11:20:00 14.5 1.8 19.1 10.3 14.2 1.8 18.7 10.3 4 6 4 305 -14.8 0 -14.4 -15 12/08/2005 11:30:00 13.8 1.6 17.6 10.3 13.8 1.5 17.2 9.9 5 6 0 305 -14.7 0 -14.4 -14.8 12/08/2005 11:40:00 13.4 1.4 17.6 10.3 13.3 1.3 16.8 9.9 6 6 15 305 -14.7 0 -14.3 -14.6 12/08/2005 11:50:00 13.8 1.7 17.9 9.5 13.8 1.8 18.3 9.9 7 6 7 305 -14.7 0 -14.3 -14.8 12/08/2005 12:00:00 13.7 1.7 17.9 9.5 13.6 1.7 17.6 9.9 8 6 10 305 -14.6 0 -14.3 -14.6 12/08/2005 12:10:00 13.8 1.9 17.9 9.1 13.6 1.9 17.6 8.8 8 6 10 305 -14.6 0.1 -14.3 -14.6 12/08/2005 12:20:00 13.9 1.7 17.9 8.8 13.8 1.5 17.9 9.5 6 5 4 305 -14.4 0.1 -14.1 -14.6 12/08/2005 12:30:00 13.8 1.8 17.9 9.1 13.6 1.8 17.9 9.1 5 6 2 305 -14.7 0 -14.3 -14.6 12/08/2005 12:40:00 13.3 1.7 18.3 9.5 13.2 1.6 17.9 9.1 5 6 359 305 -14.6 0.1 -14.3 -14.6 12/08/2005 12:50:00 12.5 1.8 17.6 9.1 12.5 1.8 17.6 9.5 4 6 5 305 -14.5 0.1 -14.3 -14.6 12/08/2005 13:00:00 13.3 1.7 17.6 9.5 13.1 1.7 17.6 9.5 4 6 357 305 -14.5 0.1 -14.3 -14.6 12/08/2005 13:10:00 13.5 1.7 17.9 10.3 13.5 1.7 17.6 9.5 4 6 3 305 -14.6 0.1 -14.3 -14.6 12/08/2005 13:20:00 14.2 1.8 18.3 9.1 14 1.7 18.7 8.8 3 5 357 305 -14.6 0.1 -14.3 -14.8 12/08/2005 13:30:00 13.2 1.5 18.3 9.9 13.3 1.3 18.3 10.3 3 6 9 305 -14.7 0 -14.4 -14.8 12/08/2005 13:40:00 13.1 1.7 17.2 9.9 13.1 1.6 17.6 9.5 2 5 0 305 -14.7 0 -14.3 -14.8 12/08/2005 13:50:00 13.4 1.5 17.2 9.1 13.4 1.5 17.6 9.1 2 6 3 305 -14.6 0.1 -14.3 -14.8 12/08/2005 14:00:00 12.3 1.2 15.6 9.1 12.3 1.3 15.6 9.5 2 6 8 305 -14.5 0.1 -14.3 -14.6 12/08/2005 14:10:00 13.8 1.5 17.6 9.9 13.7 1.4 16.8 9.5 0 5 0 305 -14.6 0.1 -14.3 -14.6 12/08/2005 14:20:00 12.6 1.3 16.8 8.8 12.7 1.4 17.2 9.5 1 6 5 305 -14.4 0.1 -14.1 -14.6 12/08/2005 14:30:00 13.2 1.4 16.8 9.5 13 1.5 16.8 8.8 1 5 1 305 -14.5 0.1 -14.1 -14.6 12/08/2005 14:40:00 13.7 1.6 17.2 9.5 13.7 1.6 17.2 9.5 359 6 358 305 -14.7 0 -14.3 -14.6 12/08/2005 14:50:00 15.3 1.5 18.7 11.1 15.3 1.5 18.7 11.8 359 5 359 305 -14.7 0 -14.4 -14.8 12/08/2005 15:00:00 14.2 1.8 18.3 9.5 14.1 1.8 18.3 9.5 358 5 2 305 -14.7 0 -14.3 -14.8 12/08/2005 15:10:00 14 1.7 18.3 9.5 13.9 1.8 18.7 9.5 359 6 2 305 -14.7 0 -14.3 -14.8 12/08/2005 15:20:00 13.5 1.7 17.6 9.1 13.4 1.6 17.6 8.8 358 6 1 305 -14.7 0 -14.3 -14.8 12/08/2005 15:30:00 13.2 1.5 16.8 9.1 13.1 1.5 16.8 9.1 359 6 354 305 -14.7 0 -14.3 -14.6 12/08/2005 15:40:00 12.2 1.5 16.4 8 12.1 1.5 16.8 8.4 359 6 2 305 -14.4 0 -14.1 -14.6 12/08/2005 15:50:00 12.7 1.4 16.4 9.1 12.7 1.3 16.1 9.5 359 5 359 305 -14.3 0 -13.7 -14.4 12/08/2005 16:00:00 12.5 1.3 16.1 9.1 12.4 1.3 16.1 8.4 0 5 0 305 -14.2 0 -13.7 -14.3 12/08/2005 16:10:00 12.6 1.5 16.4 9.5 12.6 1.5 16.4 8.8 1 6 5 305 -14.2 0 -13.7 -14.4 12/08/2005 16:20:00 14.3 1.7 17.9 9.5 14.1 1.5 17.6 9.9 358 5 355 305 -14.5 0.1 -14.3 -14.6 12/08/2005 16:30:00 14 1.4 17.9 9.1 13.9 1.3 17.6 9.5 358 6 356 305 -14.5 0.1 -14.3 -14.6 12/08/2005 16:40:00 13.9 1.7 17.9 9.9 13.8 1.5 17.9 9.9 358 6 7 305 -14.6 0.1 -14.3 -14.6 12/08/2005 16:50:00 13.2 1.6 17.2 9.9 13.1 1.5 17.6 8.8 357 5 354 305 -14.6 0.1 -14.3 -14.6 12/08/2005 17:00:00 14.7 1.5 17.6 8.8 14.4 1.5 17.9 9.5 356 5 352 305 -14.6 0.1 -14.3 -14.6 12/08/2005 17:10:00 12.7 1.4 16.8 9.1 12.8 1.4 16.4 9.5 356 6 351 305 -14.5 0.1 -14.3 -14.6 12/08/2005 17:20:00 12.8 1.6 17.2 9.9 12.8 1.7 17.2 9.1 358 6 1 305 -14.4 0 -13.9 -14.6 12/08/2005 17:30:00 13.8 1.7 17.6 9.1 13.7 1.6 17.6 9.1 0 6 8 305 -14.3 0 -13.9 -14.4 12/08/2005 17:40:00 13.1 1.9 17.9 8.8 13.1 1.9 17.6 8.8 358 5 355 305 -14.2 0.1 -13.7 -14.4 12/08/2005 17:50:00 13 1.7 16.8 8.8 13 1.7 16.8 8.4 0 6 4 305 -14.1 0.1 -13.7 -14.3 12/08/2005 18:00:00 13.3 1.9 17.2 9.1 13.2 1.8 17.2 9.5 0 6 358 305 -14.1 0.1 -13.7 -14.3 12/08/2005 18:10:00 13.3 1.4 16.4 9.5 13.3 1.4 16.8 9.9 0 6 9 305 -14.1 0.1 -13.7 -14.3 12/08/2005 18:20:00 13 1.7 17.2 8.8 13 1.7 17.6 9.1 359 6 358 305 -14.1 0.1 -13.7 -14.3 12/08/2005 18:30:00 13.9 1.5 17.2 9.1 13.7 1.6 17.6 9.5 0 5 358 305 -14.2 0.1 -13.7 -14.4 12/08/2005 18:40:00 13.9 1.6 17.2 9.9 13.9 1.7 17.2 9.9 0 5 357 305 -14.2 0.1 -13.7 -14.4 12/08/2005 18:50:00 12.9 1.6 16.1 9.1 12.8 1.5 16.4 8.8 1 5 3 305 -14.2 0 -13.7 -14.4 12/08/2005 19:00:00 13.7 1.5 17.2 9.5 13.5 1.5 17.6 9.9 1 6 354 305 -14.3 0 -13.9 -14.4 12/08/2005 19:10:00 12.9 1.9 17.2 8.4 12.8 1.8 17.2 9.1 358 6 357 305 -14.4 0 -13.9 -14.4 12/08/2005 19:20:00 12.8 1.3 16.8 9.9 12.8 1.2 16.1 10.3 358 6 353 305 -14.3 0.1 -13.7 -14.4 12/08/2005 19:30:00 14.1 1.5 17.6 9.1 13.9 1.5 17.2 9.1 0 5 8 305 -14.3 0 -13.9 -14.4 12/08/2005 19:40:00 13.7 1.9 17.2 8.8 13.6 1.7 17.2 9.1 356 5 3 305 -14.3 0 -13.9 -14.4 12/08/2005 19:50:00 14 1.5 17.6 9.9 13.8 1.5 17.6 10.7 356 5 1 305 -14.4 0 -13.9 -14.6 12/08/2005 20:00:00 13.4 1.7 18.3 9.9 13.3 1.7 17.6 9.1 356 6 359 305 -14.4 0 -14.1 -14.6 12/08/2005 20:10:00 13.6 1.8 17.2 8.8 13.6 1.8 17.2 8.4 356 6 0 305 -14.4 0.1 -14.1 -14.6 12/08/2005 20:20:00 13.8 1.4 17.2 9.9 13.8 1.3 16.8 10.7 354 5 351 305 -14.6 0.1 -14.3 -14.6 12/08/2005 20:30:00 14 1.3 17.2 11.1 14 1.3 16.8 10.3 356 5 358 305 -14.6 0 -14.3 -14.6 12/08/2005 20:40:00 12.7 1.7 16.8 8.4 12.7 1.7 16.8 8 354 6 343 305 -14.6 0.1 -14.3 -14.6 12/08/2005 20:50:00 12.3 1.3 15.6 8.4 12.2 1.3 16.8 8.8 353 6 351 305 -14.6 0 -14.3 -14.6 12/08/2005 21:00:00 12.2 1.5 16.4 8.4 12.3 1.5 16.1 8.4 356 6 4 305 -14.6 0.1 -14.3 -14.6 12/08/2005 21:10:00 13.2 1.6 16.8 9.1 13.1 1.5 16.4 9.5 357 6 357 305 -14.7 0 -14.4 -14.8 12/08/2005 21:20:00 14 1.3 17.6 11.1 13.8 1.3 17.2 10.3 358 5 357 305 -14.9 0.1 -14.6 -15 12/08/2005 21:30:00 14.1 1.6 17.6 9.5 13.9 1.7 17.6 10.3 357 5 357 305 -15 0.1 -14.6 -15.2 12/08/2005 21:40:00 13.6 1.3 16.4 10.7 13.6 1.3 16.8 10.3 354 5 350 305 -15.1 0.1 -14.6 -15.2 12/08/2005 21:50:00 13.1 1.5 16.1 8.8 13 1.6 16.4 8.4 355 5 356 305 -15 0.1 -14.6 -15 12/08/2005 22:00:00 12 1.7 15.6 8 11.9 1.6 15.3 8 357 6 357 305 -15 0.1 -14.6 -15 12/08/2005 22:10:00 12.2 1.2 16.1 9.1 12.2 1.3 16.1 8.8 359 6 346 305 -15 0.1 -14.6 -15 12/08/2005 22:20:00 12.5 1.3 16.1 9.1 12.6 1.5 16.4 9.1 357 6 2 305 -15 0 -14.6 -15 12/08/2005 22:30:00 12.4 1.3 15.3 9.1 12.4 1.4 16.1 8.8 356 5 354 305 -15 0.1 -14.6 -15 12/08/2005 22:40:00 12.5 1.3 15.6 9.1 12.6 1.3 15.6 9.5 356 5 1 305 -15.1 0.1 -14.8 -15.2 12/08/2005 22:50:00 12.1 1.3 15.3 8.4 12 1.2 14.9 9.1 357 5 5 305 -15.2 0.1 -14.8 -15.2 12/08/2005 23:00:00 11.8 1.3 15.3 8.8 11.8 1.3 14.9 9.1 355 5 2 305 -15.2 0 -15 -15.4 12/08/2005 23:10:00 12.5 1.3 15.3 9.1 12.5 1.2 15.3 9.5 356 5 355 305 -15.2 0 -15 -15.4 12/08/2005 23:20:00 13.6 2 17.2 8.4 13.5 1.8 17.6 7.6 0 5 356 305 -15.2 0 -14.8 -15.4 12/08/2005 23:30:00 13.2 1.5 16.8 9.5 13.2 1.5 17.6 9.9 0 6 359 305 -15.2 0 -14.8 -15.4 12/08/2005 23:40:00 12 1.7 16.4 8.4 12 1.7 16.8 8.4 0 6 2 305 -15.3 0 -15 -15.4 12/08/2005 23:50:00 13.4 1.3 16.1 10.3 13.2 1.4 16.4 9.5 357 5 359 305 -15.3 0 -15 -15.6 12/09/2005 00:00:00 13.5 1.4 16.1 9.1 13.6 1.5 16.4 9.1 355 5 356 305 -15.3 0 -15 -15.6 12/09/2005 00:10:00 12.7 1.3 15.6 9.1 12.7 1.3 15.3 9.1 354 5 351 305 -15.3 0 -15 -15.4 12/09/2005 00:20:00 12.1 1.5 15.6 8.8 12.2 1.4 15.6 8.8 353 6 359 305 -15.2 0 -15 -15.2 12/09/2005 00:30:00 11.3 1.6 14.5 7.6 11.3 1.5 14.9 7.6 355 6 356 305 -15.1 0 -14.6 -15.2 12/09/2005 00:40:00 12 1.3 14.5 8.8 12.2 1.3 15.3 8.8 354 5 356 305 -15 0 -14.8 -15 12/09/2005 00:50:00 11.9 1.3 14.9 8.4 12 1.3 14.9 8.8 353 5 351 305 -14.9 0 -14.6 -15 12/09/2005 01:00:00 11.9 1.2 15.3 8.4 11.9 1.2 15.3 8.4 352 6 350 305 -14.9 0 -14.6 -15 12/09/2005 01:10:00 11.5 1.2 14.1 8.4 11.5 1.3 14.5 8.8 351 5 347 305 -14.9 0 -14.6 -15 12/09/2005 01:20:00 11.6 1.5 14.5 7.6 11.7 1.6 14.9 7.2 351 6 348 305 -14.9 0 -14.6 -15 12/09/2005 01:30:00 12.6 1.1 14.9 8.8 12.6 1.1 14.9 9.5 353 5 357 305 -15 0 -14.6 -15 12/09/2005 01:40:00 11.6 1.3 14.5 8.4 11.7 1.3 14.5 8.8 354 5 352 305 -15 0 -14.6 -15 12/09/2005 01:50:00 11.9 1.3 14.5 8.8 11.9 1.2 14.5 8.8 355 5 355 305 -14.9 0 -14.6 -15 12/09/2005 02:00:00 11.9 1 14.1 8.8 11.8 1.1 14.5 9.1 359 5 359 305 -14.9 0 -14.6 -15 12/09/2005 02:10:00 10.9 1.6 13.7 7.2 10.9 1.6 14.9 7.2 356 6 355 305 -14.8 0 -14.6 -15 12/09/2005 02:20:00 11.3 1.6 14.1 7.2 11.3 1.6 14.5 7.6 356 5 356 305 -14.9 0 -14.6 -15 12/09/2005 02:30:00 10.6 1.3 13.3 6.8 10.6 1.2 13.3 7.2 354 7 358 305 -14.8 0 -14.4 -15 12/09/2005 02:40:00 10.1 1.5 13.3 6.1 10.2 1.6 14.1 6.5 352 7 354 305 -14.8 0 -14.4 -15 12/09/2005 02:50:00 10.2 1.4 13 6.5 10.2 1.4 13.3 6.8 352 6 352 305 -14.7 0 -14.4 -15 12/09/2005 03:00:00 10.6 1.3 13 7.2 10.7 1.3 13.3 7.2 352 6 352 305 -14.7 0 -14.4 -15 12/09/2005 03:10:00 9.6 1.2 13 6.8 9.7 1.2 13.3 7.2 356 6 353 305 -14.7 0 -14.4 -14.8 12/09/2005 03:20:00 10.4 1.2 13 6.1 10.4 1.3 13.3 5.7 359 6 350 305 -14.7 0 -14.4 -14.8 12/09/2005 03:30:00 10.6 1.4 14.1 6.8 10.6 1.5 13.7 6.8 355 5 357 305 -14.7 0 -14.4 -14.8 12/09/2005 03:40:00 10.1 1.3 13 6.8 10.3 1.4 13.7 7.2 354 6 352 305 -14.7 0 -14.3 -14.8 12/09/2005 03:50:00 10.8 1.4 13.7 7.2 10.9 1.3 14.1 8 357 6 354 305 -14.7 0 -14.3 -14.8 12/09/2005 04:00:00 10.6 1 13 7.2 10.6 1.1 13.3 7.6 357 6 351 305 -14.7 0 -14.3 -14.6 12/09/2005 04:10:00 10.9 1.3 13.3 7.2 10.9 1.3 13.7 7.2 357 6 3 305 -14.7 0 -14.3 -14.8 12/09/2005 04:20:00 10 1.7 13.3 5.7 10.1 1.7 13.7 6.5 359 6 358 305 -14.7 0 -14.3 -14.6 12/09/2005 04:30:00 10.6 1.5 14.1 7.2 10.5 1.5 13.7 7.2 357 6 350 305 -14.7 0 -14.3 -14.6 12/09/2005 04:40:00 9.2 1.3 12.6 5.7 9.2 1.3 12.2 6.1 357 6 350 305 -14.7 0 -14.4 -14.6 12/09/2005 04:50:00 10.7 1.1 13.7 7.2 10.7 1.2 14.1 7.2 357 6 356 305 -14.7 0 -14.4 -14.6 12/09/2005 05:00:00 10.9 1.2 14.1 8 11 1.3 13.3 8 356 5 355 305 -14.7 0 -14.3 -14.8 12/09/2005 05:10:00 10.4 1.2 13.3 7.2 10.5 1.3 13.7 7.6 358 5 1 305 -14.7 0 -14.4 -14.8 12/09/2005 05:20:00 10.5 1.2 13.3 6.8 10.4 1.2 13.3 8 356 6 351 305 -14.7 0 -14.4 -14.8 12/09/2005 05:30:00 9.8 1.2 12.6 6.8 9.9 1.3 12.6 6.5 356 5 1 305 -14.7 0 -14.3 -14.8 12/09/2005 05:40:00 9.6 1.2 12.2 6.5 9.5 1.2 12.2 6.8 358 6 355 305 -14.7 0 -14.3 -14.8 12/09/2005 05:50:00 10.4 1.3 13.3 6.8 10.4 1.4 13.3 7.2 356 5 352 305 -14.6 0.1 -14.3 -14.6 12/09/2005 06:00:00 10.5 1 13.3 7.2 10.4 1 13 8 355 6 356 305 -14.6 0.1 -14.3 -14.6 12/09/2005 06:10:00 9.9 1.2 12.6 6.5 10 1.3 13 6.1 357 5 356 305 -14.5 0.1 -14.1 -14.6 12/09/2005 06:20:00 9.8 1.1 12.6 7.2 9.9 1.1 13 7.6 357 6 359 305 -14.5 0 -14.3 -14.6 12/09/2005 06:30:00 10 1.3 13 7.2 10.1 1.3 13 7.2 357 6 356 305 -14.4 0 -14.3 -14.6 12/09/2005 06:40:00 9.3 0.9 11.5 7.2 9.3 0.9 11.5 6.8 358 6 6 305 -14.4 0 -14.3 -14.6 12/09/2005 06:50:00 9.7 1.3 13 6.8 9.6 1.3 13.3 7.2 357 6 350 305 -14.4 0 -14.1 -14.6 12/09/2005 07:00:00 9.6 1.1 12.6 6.8 9.5 1 12.2 7.2 355 6 351 305 -14.3 0 -13.9 -14.4 12/09/2005 07:10:00 9.7 1 12.2 6.5 9.8 1.1 12.6 7.2 359 6 355 305 -14.2 0.1 -13.7 -14.4 12/09/2005 07:20:00 9.6 1.1 12.6 6.5 9.6 1.1 12.6 6.8 353 6 356 305 -14.1 0.1 -13.7 -14.3 12/09/2005 07:30:00 8.9 1.1 11.5 6.5 8.9 1 11.5 6.5 350 5 358 305 -14.3 0 -13.7 -14.4 12/09/2005 07:40:00 9.1 0.9 11.5 6.8 9.1 0.9 11.8 6.8 351 5 345 305 -14.2 0 -13.9 -14.4 12/09/2005 07:50:00 8.3 1 11.1 5.3 8.3 1 11.1 5.7 346 5 345 305 -14.3 0.1 -13.9 -14.6 12/09/2005 08:00:00 7.6 0.8 9.5 5.3 7.6 0.8 9.9 5.3 343 6 352 305 -14.4 0 -14.3 -14.6 12/09/2005 08:10:00 7.3 0.9 9.5 4.9 7.2 1 9.5 4.9 342 6 343 305 -14.5 0.1 -14.3 -14.6 12/09/2005 08:20:00 7.6 1 9.9 5.3 7.6 1 9.9 5.3 344 5 344 305 -14.4 0.1 -14.3 -14.6 12/09/2005 08:30:00 8.3 0.8 9.9 6.5 8.3 0.7 9.9 6.5 340 6 341 305 -14.4 0.1 -14.1 -14.6 12/09/2005 08:40:00 7.4 0.8 9.5 5.3 7.3 0.8 9.9 5.3 341 6 339 305 -14.5 0.1 -14.1 -14.6 12/09/2005 08:50:00 7.1 0.7 9.1 4.9 7 0.8 8.8 5.3 340 7 343 305 -14.6 0 -14.4 -14.6 12/09/2005 09:00:00 7.2 0.8 9.1 4.9 7.2 0.8 9.1 5.3 343 6 344 305 -14.6 0 -14.3 -14.6 12/09/2005 09:10:00 7.3 0.7 9.1 5.7 7.1 0.7 9.1 5.3 339 6 345 305 -14.7 0 -14.3 -14.8 12/09/2005 09:20:00 6.9 0.8 9.1 4.2 6.8 0.8 9.5 4.9 336 6 343 305 -14.7 0 -14.4 -14.8 12/09/2005 09:30:00 7.4 0.9 9.5 5.3 7.2 0.9 9.1 4.9 340 6 343 305 -14.5 0.1 -14.1 -14.6 12/09/2005 09:40:00 7.3 1.1 10.7 4.6 7.4 1.1 11.1 4.6 347 8 355 305 -14.3 0.1 -13.9 -14.6 12/09/2005 09:50:00 8 1.2 11.1 5.3 8 1.1 10.7 5.3 349 7 355 305 -14.1 0.1 -13.7 -14.3 12/09/2005 10:00:00 9.2 0.8 11.5 6.8 9.2 0.8 12.2 7.2 346 5 350 305 -14 0 -13.7 -14.1 12/09/2005 10:10:00 8.8 1 11.1 6.5 8.8 1.1 11.5 6.1 344 5 338 305 -13.9 0 -13.5 -14.1 12/09/2005 10:20:00 8.6 1.1 10.7 5.7 8.7 1.1 11.1 6.1 348 5 350 305 -13.8 0 -13.7 -14.1 12/09/2005 10:30:00 9 0.8 11.1 6.5 9.1 0.9 11.8 6.8 347 5 355 305 -13.8 0 -13.3 -13.9 12/09/2005 10:40:00 8 1 9.9 5.3 8.1 0.9 10.3 5.7 346 5 340 305 -13.7 0 -13.3 -13.9 12/09/2005 10:50:00 7.9 1 9.9 5.3 8 1 10.3 5.3 346 5 346 305 -13.7 0 -13.5 -13.7 12/09/2005 11:00:00 8.1 1.1 10.7 5.7 8.3 1.1 11.1 5.7 346 6 347 305 -13.6 0.1 -13.1 -13.7 12/09/2005 11:10:00 8.3 1.2 11.1 5.3 8.5 1.2 11.1 5.7 344 5 340 305 -13.6 0 -13.3 -13.7 12/09/2005 11:20:00 8.2 0.9 10.3 6.1 8.3 0.9 10.3 6.1 341 5 344 305 -13.6 0 -13.3 -13.7 12/09/2005 11:30:00 7.6 1 9.9 4.9 7.8 1 9.9 5.3 340 6 336 305 -13.6 0.1 -13.1 -13.7 12/09/2005 11:40:00 7.8 1 9.9 4.9 7.8 1 10.3 4.9 341 6 348 305 -13.6 0.1 -13.1 -13.7 12/09/2005 11:50:00 8.7 1 11.1 5.7 8.7 1 11.5 6.1 341 5 337 305 -13.6 0.1 -13.1 -13.7 12/09/2005 12:00:00 8.4 1 10.3 5.7 8.4 1.1 10.7 6.1 343 6 340 305 -13.6 0 -13.3 -13.7 12/09/2005 12:10:00 8.2 1.2 11.1 5.3 8.4 1.2 11.1 6.1 341 5 343 305 -13.7 0 -13.3 -14.1 12/09/2005 12:20:00 8 1 10.3 5.7 8 1 10.3 5.3 342 6 333 305 -13.9 0.1 -13.5 -14.1 12/09/2005 12:30:00 7.1 0.8 9.5 5.3 7.1 0.8 9.9 5.3 343 6 353 305 -13.9 0.1 -13.5 -14.3 12/09/2005 12:40:00 7.2 0.7 8.8 5.3 7.2 0.7 8.8 5.3 345 5 342 305 -13.9 0.1 -13.5 -14.3 12/09/2005 12:50:00 6.9 1.2 9.1 3.8 6.9 1.1 9.1 4.2 343 5 338 305 -13.9 0.1 -13.5 -14.3 12/09/2005 13:00:00 6.6 0.8 8.8 4.6 6.5 0.8 8.8 4.9 343 6 339 305 -13.9 0.1 -13.5 -14.3 12/09/2005 13:10:00 6.4 0.8 8.8 4.2 6.5 0.9 9.9 4.6 352 7 0 305 -13.9 0 -13.5 -14.1 12/09/2005 13:20:00 5.8 0.6 7.2 4.6 5.9 0.6 7.6 4.2 358 5 356 305 -14 0.1 -13.3 -14.3 12/09/2005 13:30:00 5 0.6 6.8 3.4 5 0.7 6.8 3 7 8 359 305 -14 0.1 -13.7 -14.3 12/09/2005 13:40:00 4.7 0.6 6.5 3.4 4.7 0.6 6.5 3.4 11 6 19 305 -14.2 0 -13.7 -14.3 12/09/2005 13:50:00 4.6 0.5 5.7 3.4 4.7 0.5 6.1 3.4 12 6 15 305 -14.2 0 -13.7 -14.4 12/09/2005 14:00:00 4.4 0.5 5.7 3 4.3 0.5 5.7 3 11 5 7 305 -14.3 0 -13.9 -14.4 12/09/2005 14:10:00 4.2 0.5 5.3 2.6 4.1 0.5 5.7 3 5 7 8 305 -14.3 0.1 -13.7 -14.4 12/09/2005 14:20:00 4.6 0.6 6.1 3 4.5 0.6 6.1 3 355 6 356 305 -14.2 0.1 -13.7 -14.3 12/09/2005 14:30:00 4.4 0.5 6.1 3 4.3 0.5 5.7 3.4 348 6 353 305 -14 0.1 -13.5 -14.3 12/09/2005 14:40:00 4.7 0.5 5.7 3.4 4.6 0.5 5.7 3.4 348 4 346 305 -13.9 0 -13.5 -14.1 12/09/2005 14:50:00 4.9 0.5 6.5 3.8 4.9 0.5 6.5 3.8 349 4 340 305 -13.8 0 -13.3 -14.1 12/09/2005 15:00:00 5.7 0.7 7.2 4.2 5.7 0.6 7.6 4.2 349 5 351 305 -13.6 0.1 -13.1 -13.7 12/09/2005 15:10:00 5.4 0.7 6.8 3.8 5.4 0.6 6.8 3.8 354 6 351 305 -13.5 0.1 -13.1 -13.7 12/09/2005 15:20:00 5.6 0.7 7.2 3.4 5.7 0.7 7.6 3.8 345 5 341 305 -13.5 0.1 -13.1 -13.7 12/09/2005 15:30:00 4.1 0.6 6.1 3 4.2 0.6 6.1 2.6 337 5 335 305 -13.4 0.1 -12.9 -13.7 12/09/2005 15:40:00 4 0.4 5.3 3 4.1 0.4 5.3 2.6 342 5 352 305 -13.7 0 -13.3 -13.9 12/09/2005 15:50:00 4.6 0.5 6.1 3.4 4.7 0.5 6.1 3.4 357 6 351 305 -13.9 0.1 -13.3 -14.3 12/09/2005 16:00:00 4.6 0.6 6.1 3 4.7 0.6 6.5 3.4 0 6 358 305 -14.1 0.1 -13.7 -14.4 12/09/2005 16:10:00 4.4 0.5 5.7 3 4.3 0.5 5.3 3 352 6 350 305 -14.3 0 -13.9 -14.4 12/09/2005 16:20:00 5.2 0.6 6.5 3 5.1 0.6 6.5 3 355 4 358 305 -14.4 0 -14.1 -14.6 12/09/2005 16:30:00 5 0.5 6.5 3.8 5 0.5 6.8 3.8 357 4 4 305 -14.5 0.1 -14.3 -14.6 12/09/2005 16:40:00 4.2 0.8 5.7 2.6 4.3 0.8 6.1 2.3 352 7 2 305 -14.7 0 -14.3 -14.8 12/09/2005 16:50:00 4.8 0.7 6.8 3 4.8 0.6 6.8 3.4 346 7 339 305 -14.6 0.1 -14.3 -14.6 12/09/2005 17:00:00 5.1 0.5 6.5 3.8 5.1 0.5 6.5 4.2 344 5 339 305 -14.5 0.1 -14.3 -14.6 12/09/2005 17:10:00 4.4 0.5 5.7 3.4 4.3 0.5 5.7 3.4 346 4 344 305 -14.5 0.1 -14.3 -14.6 12/09/2005 17:20:00 4.6 0.6 6.1 3 4.6 0.6 6.1 3 348 6 345 305 -14.5 0.1 -14.3 -14.6 12/09/2005 17:30:00 5.3 0.5 6.5 3.8 5.2 0.5 6.8 3.8 346 5 352 305 -14.4 0 -14.1 -14.6 12/09/2005 17:40:00 5.1 0.6 6.8 3.4 5 0.6 6.5 3.8 342 5 347 305 -14.4 0 -14.1 -14.6 12/09/2005 17:50:00 5.6 1.3 9.1 3 5.6 1.3 8.8 3 346 8 345 305 -14.3 0.1 -13.7 -14.4 12/09/2005 18:00:00 6.6 0.9 8.8 4.6 6.5 0.9 9.1 4.6 349 6 345 305 -14.2 0 -13.7 -14.4 12/09/2005 18:10:00 6.9 1 9.1 4.6 6.9 0.9 9.1 4.9 349 8 341 305 -14.3 0 -13.7 -14.4 12/09/2005 18:20:00 5.5 0.7 6.8 3.8 5.5 0.7 6.8 4.2 355 6 350 305 -14.4 0 -14.1 -14.6 12/09/2005 18:30:00 5 0.6 6.8 3.8 5 0.6 6.8 3.8 358 6 355 305 -14.6 0 -14.3 -14.6 12/09/2005 18:40:00 4.4 0.5 5.7 2.6 4.3 0.5 5.7 3 9 8 17 305 -14.8 0 -14.3 -15 12/09/2005 18:50:00 5.2 0.6 7.2 3.8 5.1 0.6 6.8 3.8 357 5 0 305 -14.8 0 -14.6 -15 12/09/2005 19:00:00 3.6 0.5 4.9 2.3 3.7 0.5 4.9 2.3 4 5 355 305 -15 0.1 -14.6 -15.2 12/09/2005 19:10:00 3.6 0.5 5.3 2.6 3.5 0.5 4.6 2.3 5 7 12 305 -15.3 0 -14.8 -15.6 12/09/2005 19:20:00 3.8 0.5 5.3 3 3.8 0.4 5.7 3 3 6 4 305 -15.2 0 -15 -15.4 12/09/2005 19:30:00 3.4 0.7 4.9 1.9 3.3 0.7 4.6 1.9 10 8 8 305 -15.2 0 -15 -15.4 12/09/2005 19:40:00 2.3 0.4 3.4 1.5 2.3 0.4 3.4 1.5 3 14 358 305 -15.6 0.2 -15 -15.8 12/09/2005 19:50:00 3.3 0.5 4.6 2.3 3.1 0.5 4.6 1.5 346 8 342 305 -15.8 0 -15.4 -16 12/09/2005 20:00:00 3.3 0.4 4.2 2.3 3.1 0.4 4.2 2.3 340 7 348 305 -15.5 0 -15.2 -15.6 12/09/2005 20:10:00 3.8 0.4 4.9 2.6 3.6 0.5 4.6 2.3 333 5 333 305 -15.4 0 -15.2 -15.6 12/09/2005 20:20:00 3.4 0.5 4.2 1.9 3.2 0.4 4.2 1.9 323 10 332 305 -15.6 0.2 -15.2 -16 12/09/2005 20:30:00 2.9 0.4 3.8 2.3 2.6 0.3 3.4 1.9 319 7 323 305 -16.5 0.3 -15.8 -16.9 12/09/2005 20:40:00 2.6 0.4 3.8 1.9 2.3 0.4 3.4 1.5 321 7 327 305 -16.9 0 -16.7 -16.9 12/09/2005 20:50:00 2 0.6 3.4 0.4 1.5 0.7 3.4 0.4 326 17 322 305 -16.9 0 -16.9 -17.1 12/09/2005 21:00:00 1.4 0.7 3.4 0.4 1.1 0.5 2.6 0.4 0 32 354 305 -16.7 0.2 -16.4 -17.1 12/09/2005 21:10:00 2 0.5 3.4 0.7 1.5 0.5 3 0.4 352 11 323 305 -16.4 0 -16 -16.6 12/09/2005 21:20:00 2 0.4 3 1.1 1.5 0.5 2.6 0.4 346 7 351 305 -16.2 0.1 -16 -16.6 12/09/2005 21:30:00 2 0.3 2.6 1.1 1.5 0.4 2.3 0.4 348 5 355 305 -15.9 0 -15.8 -16 12/09/2005 21:40:00 2.2 0.2 2.6 1.5 2 0.3 2.6 1.5 351 0 352 305 -15.8 0 -15.8 -16 12/09/2005 21:50:00 2.5 0.4 4.2 1.5 2.4 0.4 4.2 1.5 347 5 331 305 -15.9 0 -15.8 -16 12/09/2005 22:00:00 2.5 0.4 3.8 1.5 2.4 0.4 3.8 1.1 341 9 352 305 -16 0.1 -15.8 -16.4 12/09/2005 22:10:00 3.3 0.4 4.2 2.3 3 0.5 4.2 1.9 340 5 339 305 -16.1 0 -15.8 -16.4 12/09/2005 22:20:00 3.5 0.4 4.2 2.3 3.4 0.4 4.6 2.3 344 5 339 305 -15.8 0 -15.6 -16 12/09/2005 22:30:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 349 3 348 305 -15.6 0 -15.4 -15.8 12/09/2005 22:40:00 3.6 0.2 4.2 3 3.6 0.3 4.2 3 354 3 352 305 -15.7 0 -15.4 -15.8 12/09/2005 22:50:00 4.3 0.4 4.9 3.4 4.2 0.4 4.9 3 355 3 352 305 -15.8 0 -15.6 -16 12/09/2005 23:00:00 3.9 0.4 4.9 3 3.8 0.4 4.9 3 354 2 354 305 -15.7 0.1 -15.6 -15.8 12/09/2005 23:10:00 4 0.4 4.9 3 3.8 0.4 4.6 2.6 350 4 344 305 -15.8 0 -15.6 -15.8 12/09/2005 23:20:00 3.4 0.5 4.6 2.3 3.2 0.5 4.6 2.3 359 6 352 305 -16 0.2 -15.6 -16.4 12/09/2005 23:30:00 2.8 0.3 3.8 1.9 2.6 0.3 3 1.9 359 6 359 305 -16.2 0 -16 -16.4 12/09/2005 23:40:00 2.7 0.4 3.8 1.5 2.4 0.3 3.4 1.5 12 6 10 305 -15.9 0.1 -15.8 -16.4 12/09/2005 23:50:00 2.7 0.4 3.8 1.9 2.5 0.4 3.4 1.5 8 5 4 305 -15.8 0 -15.8 -16 12/10/2005 00:00:00 3 0.3 3.8 2.3 2.8 0.3 3.4 1.9 4 5 3 305 -15.8 0 -15.2 -16 12/10/2005 00:10:00 2.9 0.4 3.8 1.9 2.7 0.4 3.4 1.5 354 4 353 305 -16 0.1 -15.8 -16.4 12/10/2005 00:20:00 2 0.4 3 1.1 1.5 0.5 2.6 0.4 359 7 5 305 -15.9 0.1 -15.8 -16.4 12/10/2005 00:30:00 1.5 0.5 2.6 0.4 1.3 0.4 2.3 0.4 11 19 353 305 -15.8 0 -15.8 -16 12/10/2005 00:40:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 21 24 24 305 -15.9 0 -15.8 -16 12/10/2005 00:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 48 18 15 305 -16.2 0.1 -16 -16.6 12/10/2005 01:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 6 30 346 305 -16.5 0.1 -16 -16.9 12/10/2005 01:10:00 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 18 36 58 305 -16.9 0.1 -16.6 -17.3 12/10/2005 01:20:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 296 16 303 305 -16.9 0.1 -16.6 -17.3 12/10/2005 01:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 276 12 261 305 -16.5 0.3 -16 -16.9 12/10/2005 01:40:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 214 29 305 305 -16.3 0.1 -15.6 -16.6 12/10/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 0 305 305 -16.7 0.1 -16.4 -16.9 12/10/2005 02:00:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 220 35 169 305 -16.9 0 -16.9 -16.9 12/10/2005 02:10:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 145 2 152 305 -16.9 0 -16.6 -16.9 12/10/2005 02:20:00 1.2 0.5 2.3 0.4 1.3 0.5 2.6 0.4 72 23 80 305 -17.2 0.1 -16.6 -17.5 12/10/2005 02:30:00 1.2 0.5 2.6 0.4 1.3 0.4 2.6 0.4 28 12 30 305 -16.9 0.2 -16.4 -17.3 12/10/2005 02:40:00 1.1 0.3 1.9 0.4 1.3 0.3 1.9 0.7 6 8 11 305 -16.1 0.1 -15.8 -16.6 12/10/2005 02:50:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 352 6 2 305 -16.4 0.2 -15.6 -16.6 12/10/2005 03:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 6 17 347 305 -16.9 0.2 -16 -17.1 12/10/2005 03:10:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 357 11 328 305 -16.1 0.4 -15 -16.9 12/10/2005 03:20:00 1.8 0.3 2.6 0.7 1.6 0.4 2.6 0.7 359 8 353 305 -15.4 0.1 -15 -15.8 12/10/2005 03:30:00 1.8 0.3 2.6 1.1 1.7 0.3 2.6 1.1 352 7 350 305 -15.1 0 -15 -15.2 12/10/2005 03:40:00 1.5 0.4 2.3 0.7 1.4 0.3 2.6 0.7 353 9 356 305 -15.2 0 -14.6 -15.4 12/10/2005 03:50:00 2.2 0.3 3 1.1 2 0.3 2.6 1.1 340 4 335 305 -15.4 0 -15 -15.6 12/10/2005 04:00:00 2.5 0.3 3 1.5 2.2 0.3 3 1.5 346 4 340 305 -15.5 0 -15 -15.6 12/10/2005 04:10:00 2.6 0.3 3.4 1.9 2.4 0.4 3.4 1.5 344 4 346 305 -15.6 0 -15.4 -15.8 12/10/2005 04:20:00 3 0.4 5.3 2.3 2.8 0.4 3.8 1.9 351 6 354 305 -15.7 0.1 -15 -15.8 12/10/2005 04:30:00 3.7 0.3 4.6 3 3.5 0.3 4.2 2.6 354 5 359 305 -16.1 0.2 -15.6 -16.4 12/10/2005 04:40:00 3.6 0.3 4.6 3 3.3 0.3 3.8 2.3 0 4 3 305 -16.1 0.1 -15.8 -16.4 12/10/2005 04:50:00 4.3 0.4 5.3 3.4 4 0.4 5.3 3 355 4 352 305 -16.1 0.1 -15.8 -16.6 12/10/2005 05:00:00 4 0.5 5.3 2.6 3.6 0.5 4.6 2.3 1 6 355 305 -16.4 0.1 -16 -16.6 12/10/2005 05:10:00 3.4 0.5 4.6 2.3 3.1 0.5 4.6 2.3 357 8 0 305 -15.9 0 -15.8 -16.2 12/10/2005 05:20:00 3.5 0.3 4.6 2.6 3.3 0.3 4.2 2.6 348 5 332 305 -15.9 0 -15.8 -16 12/10/2005 05:30:00 3.8 0.4 4.6 3 3.7 0.4 4.6 3 343 5 348 305 -15.8 0 -15.8 -16 12/10/2005 05:40:00 3.5 0.4 4.6 2.3 3.2 0.5 4.6 1.9 341 5 337 305 -16.4 0.2 -15.8 -16.9 12/10/2005 05:50:00 3.3 0.6 4.9 1.9 2.9 0.6 4.6 1.9 339 6 334 305 -16.4 0 -16 -16.6 12/10/2005 06:00:00 4.3 0.3 5.3 3.8 4.1 0.3 4.9 3.4 341 4 347 305 -15.8 0 -15.8 -16.2 12/10/2005 06:10:00 3.8 0.3 4.6 3 3.5 0.4 4.2 2.6 348 6 341 305 -16.2 0.2 -15.8 -16.4 12/10/2005 06:20:00 3.5 0.4 4.6 2.6 3.2 0.5 4.2 2.3 359 4 357 305 -15.9 0.1 -15.6 -16.4 12/10/2005 06:30:00 3.4 0.5 4.6 2.3 3.2 0.4 4.2 2.3 9 8 3 305 -15.8 0 -15.4 -16 12/10/2005 06:40:00 3.5 0.3 4.2 2.6 3.3 0.3 3.8 2.6 18 4 13 305 -15.6 0 -15.4 -15.8 12/10/2005 06:50:00 3.5 0.3 4.6 2.6 3.3 0.3 4.2 2.6 12 3 8 305 -15.8 0 -15.6 -16 12/10/2005 07:00:00 3.8 0.3 4.6 3 3.6 0.3 4.2 2.6 12 2 15 305 -15.9 0 -15.8 -16 12/10/2005 07:10:00 3.2 0.3 3.8 2.6 3.1 0.3 3.8 2.3 23 6 13 305 -15.9 0.1 -15.8 -16.2 12/10/2005 07:20:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 27 3 29 305 -15.8 0 -15.6 -16.2 12/10/2005 07:30:00 4.1 0.2 4.9 3.4 4.1 0.2 4.6 3.4 24 3 19 305 -16 0 -15.8 -16.2 12/10/2005 07:40:00 4.7 0.4 6.1 3.8 4.6 0.3 5.7 4.2 20 3 16 305 -16.2 0.1 -16 -16.4 12/10/2005 07:50:00 5 0.5 6.5 3.8 4.8 0.4 6.1 3.8 19 5 13 305 -16.3 0 -16 -16.4 12/10/2005 08:00:00 6.2 0.8 8.4 4.2 6 0.8 8 4.2 17 5 15 305 -15.9 0.2 -15.4 -16.2 12/10/2005 08:10:00 7 0.6 8.8 5.3 6.7 0.6 8.4 5.3 17 5 19 305 -15.5 0 -15.2 -15.6 12/10/2005 08:20:00 7.2 0.9 9.1 5.3 7 0.9 9.5 4.9 16 6 17 305 -15.5 0 -15.2 -15.6 12/10/2005 08:30:00 6.3 0.6 8 4.6 6.1 0.5 7.6 4.6 19 5 22 305 -15.6 0 -15.2 -15.6 12/10/2005 08:40:00 6.3 0.9 8.8 4.6 6.2 0.9 8.8 4.2 17 5 11 305 -15.6 0 -15.2 -15.8 12/10/2005 08:50:00 6.3 0.6 8.4 4.9 6.3 0.6 8 4.6 19 6 19 305 -15.6 0 -15.2 -15.8 12/10/2005 09:00:00 6.8 0.9 8.8 4.9 6.8 0.8 9.1 4.9 16 5 11 305 -15.6 0 -15.2 -15.8 12/10/2005 09:10:00 6.7 0.7 8.4 4.9 6.4 0.7 8 4.2 21 5 20 305 -15.6 0 -15.2 -15.8 12/10/2005 09:20:00 6.9 0.7 8.8 4.9 6.7 0.7 8.4 4.9 19 5 15 305 -15.4 0.1 -15 -15.6 12/10/2005 09:30:00 6.5 0.7 8.4 4.9 6.3 0.6 8 4.9 18 6 18 305 -15.4 0 -15 -15.6 12/10/2005 09:40:00 6.8 0.7 8.8 5.3 6.8 0.7 8.8 4.9 18 5 19 305 -15.3 0 -15 -15.6 12/10/2005 09:50:00 6.4 0.9 8.4 4.2 6.3 1 8.8 4.6 17 6 27 305 -15.2 0.1 -14.8 -15.4 12/10/2005 10:00:00 5.8 0.9 8.4 3.8 5.7 0.9 8 3.8 17 6 17 305 -15.2 0 -15 -15.4 12/10/2005 10:10:00 5.5 0.9 8.8 3.4 5.4 0.8 8.4 3.4 18 7 7 305 -15.4 0 -15 -15.6 12/10/2005 10:20:00 6.8 0.8 8.8 4.6 6.7 0.9 9.1 4.6 18 6 22 305 -15.3 0 -15 -15.6 12/10/2005 10:30:00 5.6 0.8 7.6 3.8 5.5 0.8 7.2 3.8 25 8 30 305 -15.5 0.1 -15 -15.8 12/10/2005 10:40:00 6.6 0.6 8 4.9 6.4 0.6 7.6 4.9 27 5 21 305 -15.6 0 -15.2 -15.8 12/10/2005 10:50:00 6.3 0.8 8.4 4.6 6 0.8 7.6 4.2 27 6 33 305 -15.7 0.1 -15.4 -15.8 12/10/2005 11:00:00 5.7 0.8 7.6 3.8 5.4 0.7 7.6 3.8 26 6 18 305 -15.8 0 -15.6 -16 12/10/2005 11:10:00 5.1 0.5 6.5 3.8 4.9 0.5 6.5 3.4 32 7 24 305 -15.8 0 -15.6 -16 12/10/2005 11:20:00 5.6 0.5 6.8 4.2 5.4 0.5 6.8 4.2 32 5 43 305 -15.8 0 -15.6 -16 12/10/2005 11:30:00 5.4 0.5 6.8 4.2 5.2 0.5 6.8 4.2 28 6 29 305 -15.6 0.1 -15.2 -15.8 12/10/2005 11:40:00 5.3 0.5 6.5 4.2 5.1 0.5 6.5 4.2 27 5 25 305 -15.6 0.1 -15.2 -15.8 12/10/2005 11:50:00 5.4 0.5 7.2 3.8 5.1 0.5 6.8 3.8 25 5 18 305 -15.6 0.1 -15.2 -15.8 12/10/2005 12:00:00 5.9 0.6 7.2 4.2 5.7 0.6 7.2 4.2 22 5 20 305 -15.5 0 -15 -15.8 12/10/2005 12:10:00 6.3 0.7 7.6 4.6 6.1 0.7 7.6 4.2 21 5 15 305 -15.3 0 -15 -15.6 12/10/2005 12:20:00 5.9 0.5 7.2 4.6 5.7 0.5 7.2 4.2 20 5 17 305 -15.3 0 -15 -15.4 12/10/2005 12:30:00 5.9 0.5 8 4.2 5.8 0.6 8 4.2 19 5 20 305 -15.3 0 -15 -15.4 12/10/2005 12:40:00 5.5 0.5 6.5 4.2 5.3 0.5 6.8 3.8 20 4 24 305 -15.3 0 -15 -15.6 12/10/2005 12:50:00 5.1 0.5 6.8 3.8 4.8 0.5 6.5 3.8 27 6 40 305 -15.5 0 -15 -15.6 12/10/2005 13:00:00 5.6 0.6 6.8 4.2 5.4 0.6 7.2 4.2 31 5 27 305 -15.5 0 -15 -15.6 12/10/2005 13:10:00 5.6 0.5 6.8 4.6 5.5 0.5 7.2 4.2 32 4 38 305 -15.5 0 -15 -15.6 12/10/2005 13:20:00 5.3 0.5 6.8 4.2 5.1 0.5 6.5 3.8 33 5 23 305 -15.6 0 -15.2 -15.8 12/10/2005 13:30:00 5.2 0.8 7.2 3.8 5.1 0.7 6.8 3.8 31 6 36 305 -15.5 0.1 -15.2 -15.8 12/10/2005 13:40:00 5 0.5 6.5 3.8 4.8 0.5 6.5 3.8 33 5 36 305 -15.5 0 -15.2 -15.6 12/10/2005 13:50:00 5.5 0.4 6.5 3.8 5.3 0.5 6.5 4.2 32 5 32 305 -15.5 0 -15 -15.6 12/10/2005 14:00:00 5 0.5 6.1 3.8 4.8 0.5 5.7 3.4 24 5 21 305 -15.5 0 -15 -15.6 12/10/2005 14:10:00 5.1 0.7 7.2 3.8 5 0.6 6.8 3.4 26 5 24 305 -15.5 0 -15 -15.6 12/10/2005 14:20:00 4.9 0.5 6.1 3.4 4.8 0.5 6.1 3.4 32 5 38 305 -15.5 0.1 -15 -15.8 12/10/2005 14:30:00 5.2 0.6 6.8 3.8 5 0.6 6.5 3.8 32 6 35 305 -15.6 0.1 -15.2 -15.8 12/10/2005 14:40:00 4.6 0.5 5.7 3.4 4.4 0.4 5.3 3.4 30 6 25 305 -15.7 0.1 -15.2 -15.8 12/10/2005 14:50:00 4.4 0.5 6.1 3.4 4.2 0.5 5.7 3 36 6 36 305 -15.8 0 -15.4 -16 12/10/2005 15:00:00 4.5 0.5 6.1 3.4 4.3 0.5 5.7 3 39 6 35 305 -15.8 0 -15.6 -16 12/10/2005 15:10:00 4.5 0.5 6.5 3.4 4.3 0.5 5.7 3.4 40 5 44 305 -15.8 0 -15.6 -16 12/10/2005 15:20:00 4.8 0.6 6.5 3.4 4.7 0.6 6.5 3.4 41 5 41 305 -15.8 0 -15.6 -16 12/10/2005 15:30:00 4.5 0.4 5.7 3.4 4.4 0.4 5.3 3.4 43 5 45 305 -15.8 0 -15.6 -16 12/10/2005 15:40:00 4.3 0.5 5.3 3 4.1 0.6 5.3 3 38 5 26 305 -15.9 0 -15.6 -16.2 12/10/2005 15:50:00 4.5 0.6 5.7 3 4.3 0.6 6.1 3 39 6 44 305 -16 0 -15.8 -16.2 12/10/2005 16:00:00 5.2 0.4 6.1 4.2 4.9 0.5 6.1 3.8 36 4 42 305 -15.9 0 -15.6 -16.2 12/10/2005 16:10:00 4.6 0.6 5.7 2.6 4.2 0.6 5.3 2.6 38 5 37 305 -16 0.1 -15.8 -16.2 12/10/2005 16:20:00 4.4 0.5 5.7 3.4 4.2 0.5 5.7 3 40 6 35 305 -16.1 0.1 -15.8 -16.4 12/10/2005 16:30:00 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.6 42 5 43 305 -16.2 0.1 -16 -16.4 12/10/2005 16:40:00 3 0.4 4.2 2.3 2.8 0.4 3.8 1.9 43 6 44 305 -16.2 0.1 -16 -16.4 12/10/2005 16:50:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 2.3 44 5 51 305 -16 0 -15.8 -16.2 12/10/2005 17:00:00 2.7 0.3 3.4 1.9 2.8 0.3 3.4 2.3 43 5 48 305 -15.9 0 -15.8 -16 12/10/2005 17:10:00 2.7 0.3 3.4 2.3 2.8 0.3 3.4 2.3 44 4 48 305 -15.9 0 -15.8 -16 12/10/2005 17:20:00 2.7 0.3 3.4 1.9 2.8 0.3 3.8 1.9 43 6 41 305 -15.9 0 -15.8 -16.2 12/10/2005 17:30:00 2.8 0.2 3.4 2.3 2.8 0.3 3.4 2.3 46 7 46 305 -15.8 0 -15.6 -16 12/10/2005 17:40:00 2.9 0.4 3.8 2.3 2.9 0.4 3.8 2.3 44 4 43 305 -15.9 0 -15.8 -16.2 12/10/2005 17:50:00 3.1 0.3 4.2 2.3 3.1 0.3 3.8 2.3 40 4 42 305 -15.9 0 -15.8 -16 12/10/2005 18:00:00 2.9 0.3 3.8 2.3 2.9 0.3 3.8 2.3 40 5 45 305 -15.9 0 -15.8 -16.2 12/10/2005 18:10:00 2.2 0.3 3 1.5 2.2 0.3 3 1.1 38 6 36 305 -15.9 0 -15.8 -16 12/10/2005 18:20:00 2 0.4 2.6 1.1 2 0.3 3 1.1 40 7 30 305 -15.9 0 -15.8 -16 12/10/2005 18:30:00 2.2 0.5 3.4 1.1 2.2 0.4 3.4 1.1 38 11 35 305 -15.8 0 -15.6 -16 12/10/2005 18:40:00 2.2 0.6 4.2 0.7 2.1 0.5 3.8 1.1 50 10 58 305 -15.9 0 -15.8 -16.2 12/10/2005 18:50:00 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.5 51 7 45 305 -16.1 0.1 -16 -16.2 12/10/2005 19:00:00 2.6 0.4 3.4 1.9 2.6 0.3 3.4 1.9 50 8 53 305 -16 0 -15.8 -16.2 12/10/2005 19:10:00 2.3 0.4 3.4 1.5 2.4 0.3 3.4 1.5 49 6 40 305 -16 0 -15.8 -16.4 12/10/2005 19:20:00 2.2 0.3 3 1.5 2.3 0.3 3 1.5 43 7 47 305 -16.2 0 -16 -16.4 12/10/2005 19:30:00 2.6 0.4 3.8 1.9 2.5 0.4 3.8 1.5 37 8 29 305 -16.2 0 -16 -16.4 12/10/2005 19:40:00 3 0.4 4.2 2.3 2.8 0.4 4.2 1.9 35 7 27 305 -16.3 0 -16 -16.6 12/10/2005 19:50:00 2.8 0.5 4.2 1.9 2.6 0.4 3.4 1.9 37 9 25 305 -16.4 0 -16.2 -16.6 12/10/2005 20:00:00 2.9 0.4 4.2 1.9 2.7 0.4 4.2 1.9 36 7 31 305 -16.5 0.1 -16.2 -16.9 12/10/2005 20:10:00 3.7 0.5 4.9 2.6 3.4 0.5 4.9 2.3 33 7 27 305 -16.7 0.1 -16.2 -16.9 12/10/2005 20:20:00 3.3 0.5 4.6 2.3 3.2 0.4 4.2 1.9 33 5 36 305 -16.3 0 -16 -16.6 12/10/2005 20:30:00 3.1 0.6 4.6 1.9 3.2 0.5 4.6 2.3 35 5 36 305 -16.3 0 -16 -16.6 12/10/2005 20:40:00 3.8 0.4 4.6 2.6 3.7 0.4 4.6 3 33 5 32 305 -15.9 0 -15.8 -16.2 12/10/2005 20:50:00 4.1 0.4 5.3 3 4 0.4 4.9 3 29 5 20 305 -15.8 0 -15.6 -16 12/10/2005 21:00:00 4.1 0.4 5.3 3 4 0.4 4.9 3 28 5 36 305 -15.8 0 -15.6 -16 12/10/2005 21:10:00 4 0.4 4.9 2.6 4 0.4 4.9 3 25 5 27 305 -15.8 0 -15.6 -16 12/10/2005 21:20:00 3.5 0.4 4.2 2.6 3.6 0.3 4.6 2.6 29 6 29 305 -15.7 0.1 -15.2 -15.8 12/10/2005 21:30:00 3.6 0.5 4.9 2.3 3.6 0.5 4.9 2.6 33 6 35 305 -15.8 0.1 -15.4 -16 12/10/2005 21:40:00 3.9 0.4 4.9 3 3.9 0.5 5.3 3 34 7 37 305 -15.7 0.1 -15.4 -16 12/10/2005 21:50:00 4.3 0.4 5.3 3.4 4.5 0.4 5.3 3.4 39 5 44 305 -15.7 0.1 -15.4 -16 12/10/2005 22:00:00 4.6 0.4 5.3 3.4 4.7 0.5 6.1 3.8 38 6 34 305 -15.6 0.1 -15.2 -15.8 12/10/2005 22:10:00 4.3 0.5 5.7 3 4.3 0.5 5.7 3 36 7 36 305 -15.8 0 -15.6 -16 12/10/2005 22:20:00 4.6 0.4 5.7 3.8 4.7 0.3 5.7 3.8 33 3 35 305 -15.7 0.1 -15.2 -16 12/10/2005 22:30:00 4.6 0.4 5.3 3.4 4.7 0.5 5.7 3.4 36 5 36 305 -15.8 0.2 -15.4 -16.4 12/10/2005 22:40:00 4.5 0.3 5.3 3.8 4.7 0.4 5.7 3.4 41 5 37 305 -16.2 0.1 -16 -16.4 12/10/2005 22:50:00 4.5 0.4 5.7 3.4 4.6 0.4 5.7 3.4 38 6 36 305 -15.9 0 -15.6 -16.2 12/10/2005 23:00:00 4.8 0.4 6.1 3.8 4.9 0.5 6.1 4.2 35 5 36 305 -15.7 0 -15.4 -15.8 12/10/2005 23:10:00 5.1 0.4 5.7 4.2 5.2 0.3 6.1 4.2 33 4 25 305 -15.6 0 -15.2 -15.8 12/10/2005 23:20:00 4.9 0.4 6.1 4.2 5 0.4 6.1 3.8 36 5 38 305 -15.7 0.1 -15.2 -15.8 12/10/2005 23:30:00 5.2 0.4 6.1 3.8 5.2 0.5 6.8 3.8 35 4 30 305 -15.6 0.1 -15.2 -15.8 12/10/2005 23:40:00 5.1 0.4 6.1 4.2 5.3 0.4 6.1 4.6 36 4 41 305 -15.6 0.1 -15.2 -15.8 12/10/2005 23:50:00 5 0.4 6.1 3.8 5.2 0.4 6.1 4.2 36 4 38 305 -15.6 0.1 -15.2 -15.8 12/11/2005 00:00:00 4.7 0.4 5.7 3.8 4.9 0.4 6.1 4.2 35 5 37 305 -15.5 0 -15.2 -15.8 12/11/2005 00:10:00 4.5 0.4 5.3 3.4 4.6 0.4 5.7 3.8 33 4 32 305 -15.6 0.1 -15.2 -15.8 12/11/2005 00:20:00 4.1 0.4 5.3 2.6 4.1 0.5 5.3 3 32 5 30 305 -15.8 0.1 -15.4 -16 12/11/2005 00:30:00 3.5 0.5 4.9 2.3 3.6 0.5 4.9 2.6 37 7 39 305 -16.1 0.1 -15.8 -16.4 12/11/2005 00:40:00 3.2 0.3 4.2 2.3 3.2 0.3 4.2 2.3 39 7 34 305 -16.1 0.1 -15.8 -16.4 12/11/2005 00:50:00 3.3 0.3 4.2 2.6 3.4 0.3 4.2 2.6 43 6 46 305 -16.3 0.2 -16 -16.7 12/11/2005 01:00:00 3.4 0.2 4.2 2.6 3.4 0.2 4.2 3 47 5 41 305 -16.8 0.1 -16.4 -17.1 12/11/2005 01:10:00 3.1 0.4 4.2 1.9 3 0.4 4.2 1.9 36 7 29 305 -16.8 0.1 -16.4 -17.1 12/11/2005 01:20:00 3.7 0.3 4.6 3 3.7 0.3 4.6 3 32 3 30 305 -15.9 0.1 -15.8 -16.6 12/11/2005 01:30:00 3.3 0.5 4.2 2.3 3.2 0.5 4.2 2.3 35 5 33 305 -16.1 0 -15.8 -16.4 12/11/2005 01:40:00 3.3 0.3 3.8 2.6 3.3 0.3 4.2 2.6 33 4 33 305 -15.9 0 -15.8 -16.2 12/11/2005 01:50:00 2.6 0.4 3.4 1.9 2.6 0.3 3.4 1.9 27 5 32 305 -15.9 0 -15.8 -16 12/11/2005 02:00:00 3 0.4 4.2 2.3 2.9 0.3 3.8 2.3 28 5 35 305 -15.8 0 -15.6 -16 12/11/2005 02:10:00 3.3 0.4 4.2 2.3 3.2 0.4 3.8 2.3 28 4 17 305 -15.8 0 -15.6 -16 12/11/2005 02:20:00 3.3 0.5 4.2 2.3 3.1 0.4 4.2 2.3 26 5 25 305 -15.8 0 -15.6 -16 12/11/2005 02:30:00 4.3 0.4 5.3 3.4 4.3 0.4 5.7 3.4 24 5 32 305 -15.8 0 -15.6 -16 12/11/2005 02:40:00 4.1 0.5 5.3 3 4.1 0.4 5.3 3 26 6 26 305 -15.8 0 -15.6 -16 12/11/2005 02:50:00 2.8 0.5 4.2 1.5 2.7 0.5 3.8 1.9 39 6 29 305 -15.9 0 -15.8 -16.2 12/11/2005 03:00:00 2.6 0.4 3.8 1.9 2.6 0.3 3.8 1.9 36 5 28 305 -15.9 0 -15.8 -16 12/11/2005 03:10:00 2.7 0.4 3.8 1.9 2.8 0.3 3.8 1.9 26 7 14 305 -15.9 0.1 -15.8 -16.2 12/11/2005 03:20:00 3.1 0.3 3.8 1.9 3.1 0.4 3.8 1.9 19 4 17 305 -15.9 0.2 -15.6 -16.4 12/11/2005 03:30:00 3.2 0.4 4.6 2.3 3.2 0.4 4.2 2.3 21 6 30 305 -15.8 0 -15.6 -16 12/11/2005 03:40:00 2.7 0.4 3.8 1.9 2.9 0.4 3.8 1.5 12 7 16 305 -15.9 0 -15.6 -16.2 12/11/2005 03:50:00 2.8 0.3 3.4 2.3 3 0.3 3.8 1.9 11 4 14 305 -15.8 0 -15.6 -15.8 12/11/2005 04:00:00 2.6 0.4 3.8 1.9 2.8 0.3 3.8 1.9 12 5 12 305 -15.7 0 -15.4 -15.8 12/11/2005 04:10:00 2.9 0.5 4.2 1.5 3 0.4 3.8 1.9 14 5 22 305 -15.7 0.1 -15.4 -15.8 12/11/2005 04:20:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 13 5 11 305 -15.8 0 -15.6 -16 12/11/2005 04:30:00 3.4 0.5 4.6 2.3 3.4 0.4 4.6 2.6 10 5 18 305 -15.8 0 -15.6 -16 12/11/2005 04:40:00 2.5 0.4 3.8 1.5 2.6 0.3 3.4 1.9 8 6 3 305 -15.7 0 -15.4 -15.8 12/11/2005 04:50:00 2.7 0.4 3.8 1.9 2.8 0.4 4.2 1.9 6 6 11 305 -15.8 0 -15.4 -16 12/11/2005 05:00:00 3.1 0.4 4.2 1.9 3.2 0.4 4.2 2.3 2 5 0 305 -15.7 0.1 -15.2 -16 12/11/2005 05:10:00 2.9 0.4 3.8 1.9 3.1 0.4 4.2 2.3 2 5 356 305 -15.3 0 -15 -15.6 12/11/2005 05:20:00 3.7 0.7 5.3 2.3 3.7 0.7 5.3 1.9 3 6 11 305 -15.3 0.1 -15 -15.6 12/11/2005 05:30:00 4.1 0.5 5.3 3 4.1 0.5 5.7 2.6 9 5 359 305 -15.3 0 -15 -15.6 12/11/2005 05:40:00 4.2 0.5 5.7 3.4 4.3 0.5 5.7 3 12 6 10 305 -15.2 0.1 -14.8 -15.6 12/11/2005 05:50:00 4.3 0.6 5.7 2.6 4.3 0.5 5.7 2.6 13 6 17 305 -15.2 0.1 -14.8 -15.2 12/11/2005 06:00:00 3.9 0.6 5.3 2.6 4 0.6 5.3 2.6 7 6 4 305 -15 0.1 -14.6 -15.2 12/11/2005 06:10:00 4.4 0.6 6.1 3 4.6 0.6 6.5 3 1 6 359 305 -14.8 0 -14.6 -15 12/11/2005 06:20:00 4.4 0.7 6.1 3 4.6 0.7 6.5 3.4 5 6 10 305 -14.8 0 -14.6 -15 12/11/2005 06:30:00 4.2 0.5 5.3 2.6 4.4 0.5 5.3 3 8 5 6 305 -14.8 0 -14.6 -15 12/11/2005 06:40:00 4.3 0.5 5.3 3 4.5 0.5 5.7 3 8 6 14 305 -14.9 0 -14.6 -15 12/11/2005 06:50:00 4.2 0.5 5.3 2.6 4.4 0.6 5.3 2.6 7 5 1 305 -14.8 0 -14.6 -15 12/11/2005 07:00:00 3.8 0.5 4.9 2.6 3.9 0.4 4.6 2.6 10 5 14 305 -14.8 0 -14.6 -15 12/11/2005 07:10:00 3.4 0.5 4.6 2.3 3.6 0.5 4.9 2.3 13 5 19 305 -14.9 0 -14.6 -15 12/11/2005 07:20:00 3.4 0.4 4.2 1.9 3.5 0.4 4.2 2.3 12 5 21 305 -14.9 0 -14.6 -15 12/11/2005 07:30:00 3 0.4 3.8 2.3 3.3 0.3 3.8 2.3 9 5 23 305 -14.8 0 -14.6 -15 12/11/2005 07:40:00 2.9 0.5 3.8 1.9 3.1 0.5 4.2 1.9 2 8 7 305 -14.9 0.1 -14.6 -15 12/11/2005 07:50:00 3.1 0.4 3.8 1.9 3.3 0.5 4.2 2.3 4 7 9 305 -14.8 0 -14.6 -15 12/11/2005 08:00:00 3.2 0.4 4.2 1.9 3.5 0.4 4.2 2.3 359 5 0 305 -14.7 0 -14.3 -14.8 12/11/2005 08:10:00 3.5 0.5 4.6 2.3 3.7 0.5 4.6 2.3 356 5 1 305 -14.6 0 -14.3 -14.6 12/11/2005 08:20:00 4.1 0.4 4.6 2.6 4.3 0.4 5.3 3 351 5 358 305 -14.7 0 -14.3 -14.6 12/11/2005 08:30:00 4.1 0.3 4.9 3 4.2 0.4 4.9 3 350 3 353 305 -14.7 0 -14.3 -14.6 12/11/2005 08:40:00 3.8 0.4 4.6 2.6 4 0.4 4.9 3 345 7 350 305 -14.7 0 -14.3 -14.8 12/11/2005 08:50:00 3.8 0.4 4.6 3 4 0.4 4.9 2.6 335 8 320 305 -14.6 0.1 -14.3 -14.8 12/11/2005 09:00:00 3.6 0.4 4.6 2.6 3.7 0.4 4.6 2.6 329 6 320 305 -14.7 0 -14.4 -14.8 12/11/2005 09:10:00 3.9 0.4 4.6 2.6 4.1 0.4 4.9 3 328 4 331 305 -14.6 0.1 -14.3 -14.8 12/11/2005 09:20:00 3.5 0.4 4.2 2.3 3.5 0.4 4.6 2.6 328 6 321 305 -14.6 0.1 -14.3 -14.8 12/11/2005 09:30:00 3.7 0.5 4.9 2.6 3.7 0.5 4.6 2.6 320 19 311 305 -14.7 0 -14.3 -14.8 12/11/2005 09:40:00 3.4 0.3 4.6 2.3 3.5 0.4 4.6 2.6 323 5 320 305 -14.7 0 -14.3 -14.8 12/11/2005 09:50:00 3.4 0.4 4.2 2.6 3.5 0.4 4.6 2.3 316 17 310 305 -14.7 0 -14.3 -14.8 12/11/2005 10:00:00 3.8 0.3 4.9 3 3.7 0.4 4.9 3 311 30 320 305 -14.7 0 -14.4 -15 12/11/2005 10:10:00 4 0.4 5.3 2.6 3.8 0.4 4.9 2.6 309 27 316 305 -14.9 0 -14.6 -15 12/11/2005 10:20:00 4.2 0.5 5.3 2.6 4.2 0.6 5.3 2.6 316 21 307 305 -14.8 0.1 -14.4 -15 12/11/2005 10:30:00 4.3 0.4 5.3 3.4 4.2 0.5 4.9 3 314 20 324 305 -14.7 0 -14.4 -15 12/11/2005 10:40:00 3.8 0.5 4.6 2.3 3.5 0.4 4.6 2.3 299 16 295 305 -14.7 0 -14.3 -15 12/11/2005 10:50:00 4.3 0.3 4.9 3.4 3.9 0.4 4.6 2.6 292 4 296 305 -14.8 0 -14.6 -15 12/11/2005 11:00:00 4 0.4 4.9 3 3.7 0.5 4.9 2.6 300 17 301 305 -14.8 0 -14.4 -15 12/11/2005 11:10:00 4.3 0.3 5.3 3.4 4 0.3 4.9 3 297 22 296 305 -14.7 0 -14.6 -15 12/11/2005 11:20:00 4.7 0.4 5.7 3.8 4.2 0.4 5.3 3 293 9 291 305 -14.8 0 -14.4 -14.8 12/11/2005 11:30:00 4.5 0.3 5.3 3.8 4 0.4 4.9 3 291 4 283 305 -14.7 0 -14.6 -14.8 12/11/2005 11:40:00 5.3 0.4 6.5 4.6 4.9 0.4 6.1 3.4 295 13 290 305 -14.6 0 -14.4 -14.8 12/11/2005 11:50:00 5.2 0.5 6.5 3.8 4.9 0.5 6.1 3.4 297 18 301 305 -14.4 0 -14.3 -14.6 12/11/2005 12:00:00 4 0.5 5.3 2.6 3.3 0.7 4.9 1.9 283 9 288 305 -14.4 0 -13.9 -14.4 12/11/2005 12:10:00 4 0.6 5.7 2.6 2.9 0.6 4.2 1.5 274 9 265 305 -14.4 0 -13.9 -14.6 12/11/2005 12:20:00 4 0.7 5.7 2.3 2.8 0.6 4.6 1.1 269 8 273 305 -14.5 0 -14.3 -14.6 12/11/2005 12:30:00 4.7 0.7 6.1 1.9 3.3 0.6 4.9 1.5 266 6 268 305 -14.5 0 -14.3 -14.6 12/11/2005 12:40:00 4.6 0.7 6.1 2.3 3.2 0.6 4.9 1.5 264 6 266 305 -14.4 0 -14.3 -14.6 12/11/2005 12:50:00 4.6 0.7 6.1 2.3 3.2 0.7 4.6 1.5 265 8 257 305 -14.3 0 -14.3 -14.4 12/11/2005 13:00:00 5.1 0.6 6.5 2.6 3.6 0.6 4.9 1.9 264 6 256 305 -14.2 0 -13.7 -14.4 12/11/2005 13:10:00 4.7 0.7 6.1 3 3.3 0.6 4.9 1.5 270 8 264 305 -14.1 0.1 -13.7 -14.3 12/11/2005 13:20:00 4.3 0.7 6.1 2.3 3 0.7 4.9 1.5 269 7 268 305 -14 0.2 -13.7 -14.3 12/11/2005 13:30:00 3.7 0.6 5.3 2.3 2.5 0.5 4.2 1.1 268 7 274 305 -14.1 0.1 -13.7 -14.3 12/11/2005 13:40:00 3.6 0.5 4.9 2.6 2.5 0.5 3.8 1.1 271 7 273 305 -14 0.2 -13.7 -14.3 12/11/2005 13:50:00 3.8 0.5 4.9 2.3 3 0.6 4.6 1.5 282 7 275 305 -13.9 0.1 -13.5 -14.3 12/11/2005 14:00:00 3.8 0.8 5.3 1.9 2.9 0.9 4.9 0.7 277 8 273 305 -13.8 0.1 -13.3 -14.1 12/11/2005 14:10:00 3.9 0.7 6.1 2.6 2.8 0.6 4.6 1.5 266 7 246 305 -13.8 0.1 -13.3 -14.1 12/11/2005 14:20:00 4.4 0.5 5.3 3 3.2 0.5 4.6 1.5 262 5 262 305 -13.7 0.1 -13.3 -14.1 12/11/2005 14:30:00 4.5 0.5 5.7 3 3.1 0.5 4.6 1.9 264 5 256 305 -13.7 0.1 -13.3 -14.1 12/11/2005 14:40:00 4.4 0.5 5.7 2.3 3.2 0.5 4.6 1.9 273 6 279 305 -13.7 0.1 -13.3 -14.1 12/11/2005 14:50:00 4.4 0.4 5.3 3 3 0.5 4.2 1.9 270 6 273 305 -13.6 0.1 -13.3 -13.7 12/11/2005 15:00:00 3.9 0.5 5.3 2.6 2.7 0.5 4.2 1.5 270 6 273 305 -13.6 0.1 -13.1 -13.9 12/11/2005 15:10:00 3.6 0.6 4.9 2.3 2.6 0.6 4.2 1.5 274 6 273 305 -13.5 0.2 -13.1 -13.7 12/11/2005 15:20:00 3.9 0.4 4.6 2.6 3 0.5 4.2 1.9 277 5 282 305 -13.5 0.1 -12.9 -13.7 12/11/2005 15:30:00 3.4 0.4 4.2 2.3 2.4 0.4 3.4 1.1 271 5 279 305 -13.6 0 -13.3 -13.7 12/11/2005 15:40:00 3.9 0.3 4.6 2.6 2.8 0.4 3.8 1.9 271 3 273 305 -13.8 0 -13.3 -14.1 12/11/2005 15:50:00 3.8 0.4 4.6 3 2.9 0.3 3.4 1.9 277 3 272 305 -14 0.1 -13.7 -14.3 12/11/2005 16:00:00 3.3 0.3 3.8 2.6 2.4 0.4 3.4 1.1 277 5 279 305 -14.2 0 -13.7 -14.3 12/11/2005 16:10:00 2.9 0.3 3.8 2.3 2.1 0.4 3.4 0.7 279 4 281 305 -14.2 0 -13.9 -14.3 12/11/2005 16:20:00 2.5 0.2 3 1.9 1.8 0.3 2.3 1.1 282 4 283 305 -14.4 0.1 -14.3 -14.6 12/11/2005 16:30:00 2.3 0.2 2.6 1.9 1.4 0.4 2.3 0.7 278 9 293 305 -14.6 0 -14.4 -14.6 12/11/2005 16:40:00 2 0.2 2.6 1.5 1.6 0.2 1.9 0.7 286 9 274 305 -14.7 0 -14.3 -14.8 12/11/2005 16:50:00 2.3 0.2 2.6 1.5 1.4 0.3 1.9 0.7 263 4 258 305 -14.7 0 -14.6 -14.8 12/11/2005 17:00:00 1.8 0.5 3 0.4 1.5 0.4 2.6 0.7 248 13 258 305 -14.7 0 -14.3 -14.6 12/11/2005 17:10:00 1.2 0.4 2.3 0.4 1.1 0.3 1.9 0.4 228 9 220 305 -14.8 0 -14.6 -15 12/11/2005 17:20:00 1.5 0.4 2.3 0.7 1.6 0.4 2.3 0.7 209 17 224 305 -14.9 0 -14.6 -15 12/11/2005 17:30:00 1.7 0.3 2.6 0.7 1.8 0.3 2.3 0.7 202 10 205 305 -14.7 0 -14.4 -15 12/11/2005 17:40:00 1.3 0.4 2.3 0.4 1.6 0.3 2.3 0.4 192 13 205 305 -14.5 0.1 -14.3 -14.6 12/11/2005 17:50:00 1.4 0.3 2.3 0.7 1.5 0.3 2.3 0.4 208 9 208 305 -14.4 0.1 -14.3 -14.6 12/11/2005 18:00:00 0.9 0.3 1.9 0.4 1.2 0.2 1.5 0.4 197 8 190 305 -14.6 0.1 -14.3 -14.8 12/11/2005 18:10:00 1 0.3 1.5 0.4 1.3 0.2 1.9 0.7 209 10 206 305 -14.5 0.1 -14.3 -14.8 12/11/2005 18:20:00 1 0.3 1.5 0.4 1.2 0.3 1.9 0.7 203 9 208 305 -15 0.2 -14.4 -15.6 12/11/2005 18:30:00 0.5 0.2 1.1 0.4 0.8 0.3 1.5 0.4 188 3 193 305 -15.5 0.1 -15 -15.8 12/11/2005 18:40:00 0.5 0.3 1.5 0.4 0.8 0.3 1.9 0.4 196 9 191 305 -15.7 0 -15.4 -15.8 12/11/2005 18:50:00 0.8 0.3 1.9 0.4 1 0.3 1.9 0.4 191 0 191 305 -15.3 0 -15 -15.6 12/11/2005 19:00:00 0.9 0.4 1.9 0.4 1.1 0.4 1.9 0.4 193 3 199 305 -15.5 0 -15.2 -15.6 12/11/2005 19:10:00 1.6 0.2 2.3 1.1 1.7 0.2 2.3 1.1 195 2 192 305 -15.8 0.1 -15.6 -16.2 12/11/2005 19:20:00 2.7 0.3 3.4 1.9 2.8 0.4 3.4 1.9 192 2 193 305 -15.5 0.1 -15.2 -15.8 12/11/2005 19:30:00 2.2 0.3 3 1.1 2.2 0.3 3 1.5 183 2 186 305 -15.5 0 -15.2 -15.8 12/11/2005 19:40:00 2.8 0.4 3.8 1.9 2.9 0.5 3.8 1.9 187 2 189 305 -15.2 0.1 -14.8 -15.6 12/11/2005 19:50:00 2.3 0.4 3 1.1 2.4 0.5 3.4 1.5 187 4 193 305 -15.4 0.1 -15 -15.8 12/11/2005 20:00:00 2.2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 194 3 197 305 -15.6 0.1 -15.2 -15.8 12/11/2005 20:10:00 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.5 191 3 191 305 -15.7 0 -15.2 -15.8 12/11/2005 20:20:00 2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 192 2 192 305 -15.3 0.1 -14.8 -15.6 12/11/2005 20:30:00 2.2 0.2 2.6 1.9 2.4 0.2 2.6 1.9 190 4 190 305 -14.7 0.1 -14.4 -15 12/11/2005 20:40:00 2.6 0.2 3 2.3 2.9 0.2 3.4 1.9 201 2 203 305 -14.7 0 -14.3 -14.6 12/11/2005 20:50:00 2.2 0.3 3 1.5 2.5 0.3 3.4 1.5 197 3 199 305 -14.5 0.1 -14.3 -14.8 12/11/2005 21:00:00 1.4 0.3 2.3 0.7 1.7 0.2 2.3 1.1 193 2 192 305 -14.5 0.1 -14.1 -14.8 12/11/2005 21:10:00 2 0.3 2.6 1.5 2.3 0.4 3 1.5 202 6 208 305 -15 0.1 -14.6 -15.4 12/11/2005 21:20:00 2.2 0.2 2.6 1.9 2.5 0.2 3 2.3 203 3 204 305 -15.1 0.1 -14.8 -15.4 12/11/2005 21:30:00 2 0.2 2.3 1.9 2.3 0.2 2.6 1.9 201 2 205 305 -14.8 0 -14.6 -15 12/11/2005 21:40:00 1.9 0.1 2.3 1.5 2.1 0.2 2.6 1.9 204 1 203 305 -14.8 0 -14.6 -15 12/11/2005 21:50:00 2.1 0.2 2.6 1.9 2.4 0.2 2.6 1.9 201 2 197 305 -14.8 0.1 -14.6 -15 12/11/2005 22:00:00 2.3 0.2 2.6 1.9 2.5 0.2 3 1.9 200 3 202 305 -15.1 0.1 -14.6 -15.4 12/11/2005 22:10:00 2 0.2 2.3 1.5 2.2 0.2 2.6 1.5 192 3 193 305 -14.7 0.2 -14.3 -15.2 12/11/2005 22:20:00 1.8 0.3 2.6 1.1 2 0.2 2.6 1.5 206 8 213 305 -14.6 0.1 -14.3 -14.8 12/11/2005 22:30:00 1.6 0.2 2.3 1.1 1.8 0.2 2.3 1.5 210 6 211 305 -14.7 0 -14.4 -15 12/11/2005 22:40:00 1.5 0.2 1.9 1.1 1.7 0.2 2.3 1.5 207 4 209 305 -14.6 0.1 -14.3 -14.8 12/11/2005 22:50:00 1.7 0.2 2.3 1.1 1.9 0.2 2.6 1.1 208 7 220 305 -14.8 0.1 -14.3 -15 12/11/2005 23:00:00 1.7 0.3 2.3 0.7 1.9 0.2 2.6 1.1 210 9 213 305 -14.8 0.1 -14.4 -15 12/11/2005 23:10:00 1.7 0.3 2.3 0.7 1.7 0.3 2.6 1.1 221 11 207 305 -14.5 0.1 -14.3 -14.8 12/11/2005 23:20:00 1.8 0.4 2.6 0.7 1.8 0.3 2.6 1.1 226 7 222 305 -14.4 0.1 -14.1 -14.6 12/11/2005 23:30:00 2 0.3 2.6 1.1 2.1 0.2 2.6 1.5 219 6 218 305 -14.8 0 -14.4 -15 12/11/2005 23:40:00 1.3 0.3 1.9 0.7 1.5 0.3 2.3 0.7 210 10 205 305 -14.7 0.1 -14.3 -15 12/11/2005 23:50:00 1.3 0.4 2.3 0.4 1.5 0.4 2.3 0.4 222 15 219 305 -14.3 0 -13.9 -14.4 12/12/2005 00:00:00 0.6 0.3 1.5 0.4 0.9 0.4 1.9 0.4 212 18 225 305 -14.4 0 -14.3 -14.6 12/12/2005 00:10:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 196 69 278 305 -14.4 0.1 -14.1 -14.6 12/12/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 292 33 305 305 -14.1 0 -13.7 -14.3 12/12/2005 00:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 288 16 279 305 -14.4 0.2 -13.7 -15 12/12/2005 00:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 315 22 333 305 -15.2 0.1 -14.6 -15.4 12/12/2005 00:50:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 280 23 302 305 -14.1 0.3 -13.7 -14.8 12/12/2005 01:00:00 1.3 0.3 2.3 0.4 0.8 0.2 1.5 0.4 269 11 270 305 -14.2 0.3 -13.7 -15 12/12/2005 01:10:00 1.1 0.4 2.3 0.4 0.7 0.3 1.5 0.4 255 11 256 305 -14.5 0.1 -14.3 -15 12/12/2005 01:20:00 1.2 0.4 2.3 0.4 0.9 0.5 2.3 0.4 250 19 224 305 -14.6 0.5 -14.3 -16 12/12/2005 01:30:00 1.3 0.5 2.6 0.4 1.3 0.4 2.3 0.4 231 12 247 305 -15.6 0.1 -15 -16 12/12/2005 01:40:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 238 12 230 305 -14.6 0.2 -14.3 -15.2 12/12/2005 01:50:00 1.7 0.4 2.6 0.4 2.2 0.4 3 1.1 205 6 194 305 -15.8 0.3 -14.6 -16 12/12/2005 02:00:00 2.5 0.5 3.4 1.5 2.8 0.6 3.8 1.9 205 8 199 305 -15.2 0.2 -14.6 -16 12/12/2005 02:10:00 2.6 0.4 3.4 1.9 2.8 0.4 3.8 2.3 203 5 201 305 -14.4 0.4 -13.7 -15 12/12/2005 02:20:00 2.4 0.3 3.4 1.1 2.6 0.3 3.4 1.9 207 7 208 305 -14 0.1 -13.7 -14.3 12/12/2005 02:30:00 1.8 0.3 2.6 1.1 1.8 0.3 2.6 1.1 217 10 211 305 -14 0 -13.7 -14.3 12/12/2005 02:40:00 2.2 0.3 3 1.5 2.4 0.3 3 1.9 215 9 224 305 -14.3 0.2 -13.7 -14.6 12/12/2005 02:50:00 2.2 0.3 3 1.5 2.3 0.4 3 1.1 214 13 212 305 -14.5 0.1 -14.3 -14.6 12/12/2005 03:00:00 2.2 0.4 3.4 0.7 2.4 0.4 3.4 1.5 207 11 214 305 -14.2 0.2 -13.7 -14.6 12/12/2005 03:10:00 2 0.3 3 1.1 2.1 0.3 3 1.5 212 11 221 305 -14 0.1 -13.7 -14.3 12/12/2005 03:20:00 1.7 0.3 2.3 0.7 1.8 0.3 2.6 1.1 206 12 203 305 -14.1 0.1 -13.7 -14.3 12/12/2005 03:30:00 1.2 0.5 2.3 0.4 1.5 0.5 2.6 0.4 217 10 203 305 -14.2 0 -13.7 -14.4 12/12/2005 03:40:00 1.3 0.3 1.9 0.4 1.6 0.3 2.3 0.4 196 15 214 305 -14 0.2 -13.7 -14.6 12/12/2005 03:50:00 1.4 0.3 2.3 0.4 1.7 0.3 2.3 0.4 201 10 194 305 -14 0.2 -13.3 -14.6 12/12/2005 04:00:00 1.6 0.3 2.3 0.7 2 0.2 2.6 1.5 202 5 196 305 -13.9 0.1 -13.5 -14.3 12/12/2005 04:10:00 2.8 0.6 3.8 1.5 3.4 0.6 4.6 1.9 194 6 197 305 -14.2 0.1 -13.5 -14.4 12/12/2005 04:20:00 1.8 0.4 3 0.7 2.2 0.6 3.4 1.1 201 7 199 305 -14 0.2 -13.5 -14.4 12/12/2005 04:30:00 2 0.3 2.6 1.1 2.4 0.4 3.4 1.5 200 7 196 305 -14 0.1 -13.7 -14.3 12/12/2005 04:40:00 1.8 0.3 2.3 1.1 2.1 0.3 2.6 1.5 204 6 209 305 -13.9 0.1 -13.5 -14.3 12/12/2005 04:50:00 1.5 0.4 2.3 0.7 1.9 0.4 3 1.1 198 5 195 305 -13.9 0.1 -13.3 -14.3 12/12/2005 05:00:00 1.6 0.3 2.3 0.7 1.8 0.3 2.3 1.1 200 4 207 305 -13.9 0 -13.5 -14.1 12/12/2005 05:10:00 1.7 0.3 2.3 1.1 2 0.3 2.6 1.5 196 3 193 305 -13.9 0 -13.7 -14.1 12/12/2005 05:20:00 2.3 0.8 3.8 1.1 2.6 0.8 4.2 1.1 198 3 199 305 -13.9 0.1 -13.7 -14.3 12/12/2005 05:30:00 2.7 0.2 3.4 2.3 3 0.2 3.8 2.3 199 4 202 305 -14.2 0 -13.7 -14.3 12/12/2005 05:40:00 2.5 0.4 3.4 1.5 2.8 0.4 3.4 1.9 202 5 189 305 -13.8 0 -13.5 -14.1 12/12/2005 05:50:00 2.4 0.4 3.4 1.5 2.7 0.5 3.8 1.9 198 5 192 305 -13.8 0.1 -13.5 -14.3 12/12/2005 06:00:00 2.1 0.2 2.6 1.5 2.1 0.3 2.6 1.5 213 7 213 305 -14.2 0.1 -13.7 -14.4 12/12/2005 06:10:00 1.9 0.2 2.6 1.5 2.1 0.2 2.6 1.5 203 5 208 305 -14.3 0 -14.1 -14.4 12/12/2005 06:20:00 2.4 0.3 3 1.9 2.5 0.3 3.4 1.9 206 4 213 305 -14.4 0 -14.1 -14.6 12/12/2005 06:30:00 2.6 0.3 3.4 1.9 2.8 0.3 3.4 1.9 206 4 212 305 -14.2 0 -13.9 -14.3 12/12/2005 06:40:00 2.5 0.2 3 1.9 2.7 0.2 3 2.3 203 4 202 305 -14.2 0 -13.9 -14.3 12/12/2005 06:50:00 2.3 0.2 3 1.9 2.5 0.2 3 1.9 200 5 202 305 -14.1 0 -13.9 -14.3 12/12/2005 07:00:00 2.4 0.3 3 1.5 2.5 0.3 3.4 1.9 208 5 213 305 -14 0.1 -13.5 -14.3 12/12/2005 07:10:00 2.1 0.3 2.6 1.5 2.3 0.3 3 1.5 209 5 210 305 -13.9 0 -13.7 -14.3 12/12/2005 07:20:00 2.1 0.2 2.6 1.5 2.3 0.2 2.6 1.9 202 4 203 305 -13.9 0.1 -13.5 -14.1 12/12/2005 07:30:00 1.9 0.3 2.6 1.1 2.1 0.3 2.6 1.5 202 3 203 305 -13.9 0.1 -13.5 -14.3 12/12/2005 07:40:00 2.4 0.3 3 1.5 2.6 0.3 3.4 1.9 200 3 198 305 -14.1 0.1 -13.7 -14.3 12/12/2005 07:50:00 2.6 0.2 3 1.9 2.8 0.2 3.4 2.3 200 5 210 305 -14.1 0.1 -13.5 -14.4 12/12/2005 08:00:00 3 0.2 3.8 2.3 3.2 0.3 3.8 2.6 198 4 196 305 -13.8 0.1 -13.3 -14.1 12/12/2005 08:10:00 3 0.3 3.8 2.3 3.3 0.3 3.8 2.6 197 4 208 305 -13.4 0.1 -12.9 -13.9 12/12/2005 08:20:00 3 0.3 3.8 2.3 3.3 0.2 3.8 2.6 197 3 194 305 -13.1 0.1 -12.7 -13.5 12/12/2005 08:30:00 2.9 0.3 3.4 2.3 3.2 0.3 3.8 2.3 194 4 194 305 -13.5 0.1 -13.1 -13.7 12/12/2005 08:40:00 3.1 0.3 4.2 2.3 3.4 0.3 4.2 2.3 194 3 202 305 -13.3 0.2 -12.7 -13.7 12/12/2005 08:50:00 3.1 0.3 3.8 2.6 3.3 0.3 4.2 2.6 192 3 196 305 -13 0.1 -12.5 -13.3 12/12/2005 09:00:00 3.2 0.3 3.8 2.3 3.4 0.3 4.2 2.6 190 3 190 305 -12.7 0.1 -12.3 -12.9 12/12/2005 09:10:00 2.6 0.3 3.4 1.5 3.1 0.2 3.8 2.3 183 3 188 305 -12.9 0.2 -12.3 -13.3 12/12/2005 09:20:00 2.4 0.5 3.4 0.7 2.8 0.3 3.4 2.3 183 5 188 305 -13.5 0.2 -12.9 -13.9 12/12/2005 09:30:00 1.6 0.4 2.6 0.7 2.7 0.3 3.4 1.9 174 8 183 305 -13.8 0.2 -13.3 -14.3 12/12/2005 09:40:00 1.7 0.7 3.4 0.4 2.4 0.4 3.4 1.5 165 11 147 305 -14.2 0.1 -13.9 -14.6 12/12/2005 09:50:00 1 0.9 3 0.4 0.7 0.6 2.6 0.4 81 90 147 305 -13.7 0.1 -13.3 -14.1 12/12/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 321 0 305 305 -13.7 0.1 -13.3 -14.1 12/12/2005 10:10:00 0.6 0.6 3 0.4 0.7 0.8 3.8 0.4 263 64 155 305 -13.9 0.2 -13.3 -14.3 12/12/2005 10:20:00 1.4 0.8 3.4 0.4 1.5 0.8 3.4 0.4 170 39 190 305 -13.7 0.1 -13.1 -14.1 12/12/2005 10:30:00 4.4 0.7 5.3 1.9 4.4 1.1 5.7 1.5 146 6 140 305 -13.5 0.1 -12.9 -13.7 12/12/2005 10:40:00 4.5 0.2 4.9 4.2 5 0.2 5.3 4.6 147 1 150 305 -12.9 0.2 -12.1 -13.5 12/12/2005 10:50:00 4.8 0.2 5.3 4.2 5 0.2 5.3 4.6 142 2 143 305 -12.4 0.1 -12.1 -12.7 12/12/2005 11:00:00 4.7 0.3 5.3 3.8 4.7 0.2 5.3 4.2 141 1 142 305 -11.9 0.1 -11.3 -12.3 12/12/2005 11:10:00 4.8 0.3 5.7 3.4 5 0.4 5.7 4.2 140 2 136 305 -11.9 0.1 -11.5 -12.1 12/12/2005 11:20:00 5 0.3 6.1 4.2 5.1 0.4 6.1 4.2 138 3 155 305 -11.8 0 -11.5 -12.1 12/12/2005 11:30:00 4.7 0.6 5.7 2.3 4.9 0.5 6.1 2.6 138 5 141 305 -11.9 0 -11.7 -12.1 12/12/2005 11:40:00 4.9 0.3 5.7 3.4 5.2 0.3 5.7 4.2 136 3 134 305 -12 0 -11.7 -12.1 12/12/2005 11:50:00 5.2 0.4 5.7 3 5.5 0.4 6.1 3.4 136 4 139 305 -12 0.2 -11.5 -12.3 12/12/2005 12:00:00 5.8 0.2 6.5 5.3 6 0.2 6.5 5.7 134 2 134 305 -11.7 0.2 -11.3 -12.1 12/12/2005 12:10:00 6 0.4 7.2 4.6 6 0.5 7.2 4.6 133 2 136 305 -11.4 0.1 -10.9 -11.7 12/12/2005 12:20:00 6 0.3 6.5 5.3 6.1 0.3 6.8 5.3 131 2 134 305 -11.5 0.2 -11.1 -11.9 12/12/2005 12:30:00 5.8 0.3 6.5 4.6 5.8 0.3 6.5 4.9 133 3 129 305 -11.7 0.1 -11.3 -11.9 12/12/2005 12:40:00 5.7 0.5 7.2 4.6 5.6 0.5 7.2 4.6 135 4 139 305 -11.6 0.1 -11.1 -12.1 12/12/2005 12:50:00 5.6 0.6 7.2 2.6 5.6 0.5 7.2 4.2 137 5 142 305 -11.5 0.1 -10.9 -11.7 12/12/2005 13:00:00 5.8 0.5 7.2 4.6 5.8 0.5 6.8 4.6 138 4 135 305 -11.4 0.2 -10.9 -11.7 12/12/2005 13:10:00 5.3 0.7 6.8 2.6 5.4 0.5 6.8 3.8 137 7 148 305 -11.4 0.2 -10.9 -11.7 12/12/2005 13:20:00 5 0.7 7.2 2.6 5 0.7 6.8 2.6 137 8 147 305 -11.3 0.2 -10.9 -11.7 12/12/2005 13:30:00 4.6 0.6 6.1 2.3 4.9 0.5 6.1 3.4 139 8 152 305 -11.2 0.2 -10.4 -11.5 12/12/2005 13:40:00 4.8 1 6.5 1.9 4.9 1 6.5 2.6 145 9 135 305 -10.8 0.2 -10.4 -11.3 12/12/2005 13:50:00 4.9 0.9 6.5 1.9 5.2 0.6 6.5 2.6 142 9 156 305 -10.7 0.2 -10.2 -10.9 12/12/2005 14:00:00 4.2 0.9 6.1 1.5 4.5 0.9 6.1 1.9 143 12 151 305 -10.7 0.2 -10 -10.9 12/12/2005 14:10:00 1 0.9 3.8 0.4 1.3 0.8 3.8 0.4 12 82 137 305 -10.8 0.1 -10.4 -10.9 12/12/2005 14:20:00 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 38 29 28 305 -10.7 0.1 -10.4 -11.1 12/12/2005 14:30:00 0.7 0.4 1.9 0.4 1 0.5 2.3 0.4 36 23 40 305 -10.8 0.2 -10.4 -11.3 12/12/2005 14:40:00 0.4 0.2 1.5 0.4 0.7 0.4 2.3 0.4 18 12 38 305 -10.9 0.2 -10.4 -11.5 12/12/2005 14:50:00 1.2 0.9 3.4 0.4 1.2 0.8 3.4 0.4 79 47 87 305 -10.9 0 -10.7 -11.1 12/12/2005 15:00:00 3.2 0.6 4.6 1.5 3.3 0.7 4.6 1.5 127 10 129 305 -10.7 0 -10.4 -10.9 12/12/2005 15:10:00 1.5 0.8 3.8 0.4 1.7 0.7 3 0.4 66 41 108 305 -10.7 0 -10.4 -10.9 12/12/2005 15:20:00 1 0.7 3 0.4 1.2 0.8 3 0.4 73 33 78 305 -10.8 0.1 -10.4 -11.3 12/12/2005 15:30:00 1.7 0.7 3.8 0.4 2 0.6 4.2 0.7 54 32 68 305 -11.1 0 -10.7 -11.3 12/12/2005 15:40:00 0.8 0.7 3.4 0.4 1 0.6 3.4 0.4 343 90 151 305 -11 0 -10.9 -11.3 12/12/2005 15:50:00 1.3 0.9 3.4 0.4 1.5 0.8 3 0.4 92 64 112 305 -10.9 0 -10.4 -11.1 12/12/2005 16:00:00 0.5 0.3 2.3 0.4 0.7 0.5 2.3 0.4 58 82 12 305 -10.7 0 -10.4 -10.9 12/12/2005 16:10:00 2.4 1.7 4.9 0.4 2.5 1.8 6.1 0.4 125 22 127 305 -10.7 0.1 -10.4 -11.1 12/12/2005 16:20:00 5.5 1.1 7.2 2.3 5.9 1 7.6 3.4 139 9 138 305 -11.2 0.2 -10.9 -11.5 12/12/2005 16:30:00 5 0.8 6.5 2.3 5.6 0.7 7.2 3 139 9 133 305 -11.3 0.2 -10.9 -11.7 12/12/2005 16:40:00 5.1 1 6.8 2.3 5.9 0.7 6.8 3.4 142 9 141 305 -11.4 0.1 -10.9 -11.7 12/12/2005 16:50:00 4.9 0.8 6.5 3 5.9 0.7 7.2 3.4 140 8 142 305 -11.4 0.1 -10.9 -11.7 12/12/2005 17:00:00 4.4 0.9 6.1 1.5 5.5 0.7 6.8 3 139 8 138 305 -11.3 0.2 -10.7 -11.5 12/12/2005 17:10:00 4.3 0.7 6.1 2.3 5.2 0.6 6.5 2.6 139 9 143 305 -10.9 0.1 -10.4 -11.3 12/12/2005 17:20:00 3.4 0.9 4.9 1.1 4.3 1 6.1 1.1 130 27 137 305 -10.7 0.1 -10 -10.9 12/12/2005 17:30:00 1.8 0.7 4.6 0.4 2.4 0.8 5.3 1.1 26 13 47 305 -11.3 0.5 -10.4 -12.1 12/12/2005 17:40:00 1.7 0.6 3 0.7 2.3 0.7 3.8 0.7 55 15 37 305 -11.9 0.2 -11.3 -12.3 12/12/2005 17:50:00 0.5 0.3 1.9 0.4 1.3 0.4 2.3 0.4 49 9 41 305 -11.7 0.1 -11.3 -12.1 12/12/2005 18:00:00 1.2 0.7 2.6 0.4 2.2 0.6 3.8 0.4 41 11 37 305 -11.9 0.1 -11.5 -12.1 12/12/2005 18:10:00 1.1 0.4 1.9 0.4 1.7 0.4 2.6 0.7 39 9 39 305 -11.6 0.2 -10.9 -12.1 12/12/2005 18:20:00 2.3 0.5 4.2 1.1 2.9 0.5 4.6 1.9 50 4 40 305 -11.3 0.2 -10.9 -11.7 12/12/2005 18:30:00 4.1 0.5 5.3 2.6 4.7 0.5 5.7 3.4 44 6 41 305 -11.4 0.1 -10.9 -11.7 12/12/2005 18:40:00 4.9 0.4 5.7 3.8 5.1 0.4 6.1 3.8 52 6 46 305 -11.4 0.1 -10.9 -11.7 12/12/2005 18:50:00 4.8 0.4 5.7 3.4 4.9 0.4 6.1 3.4 53 4 54 305 -11.3 0.1 -11.1 -11.5 12/12/2005 19:00:00 4.9 0.4 5.7 3.8 5 0.4 6.1 3.8 52 5 56 305 -11.3 0 -11.1 -11.5 12/12/2005 19:10:00 4.5 0.4 5.3 3 4.5 0.4 5.3 3.4 53 5 48 305 -11.3 0.1 -11.1 -11.5 12/12/2005 19:20:00 4.7 0.6 6.5 3 4.8 0.6 6.1 3 52 7 58 305 -11.4 0 -11.1 -11.7 12/12/2005 19:30:00 5.2 0.6 6.1 3 5.4 0.6 6.5 3.4 53 4 60 305 -11.5 0 -11.3 -11.7 12/12/2005 19:40:00 5.5 0.5 6.8 4.2 5.6 0.5 6.8 4.2 49 5 48 305 -11.6 0 -11.5 -11.9 12/12/2005 19:50:00 5.6 0.5 6.5 4.2 5.7 0.5 6.8 3.8 54 4 50 305 -11.7 0 -11.5 -11.9 12/12/2005 20:00:00 5.9 0.4 7.2 4.9 6.1 0.4 7.2 4.9 58 3 56 305 -11.8 0.1 -11.3 -12.1 12/12/2005 20:10:00 6 0.4 7.2 4.9 6.2 0.4 7.2 4.9 57 4 61 305 -11.8 0.1 -11.3 -12.1 12/12/2005 20:20:00 6.3 0.4 7.2 5.3 6.5 0.4 7.2 5.3 57 3 56 305 -11.8 0.2 -11.3 -12.1 12/12/2005 20:30:00 5.9 0.5 7.2 4.2 6 0.5 7.2 4.6 59 5 54 305 -11.9 0.1 -11.5 -12.1 12/12/2005 20:40:00 5.3 0.5 6.5 3.8 5.4 0.5 6.5 3.8 61 5 59 305 -11.9 0.1 -11.5 -12.1 12/12/2005 20:50:00 4.5 0.8 6.1 3 4.7 0.8 6.1 2.6 57 7 54 305 -11.9 0.2 -11.3 -12.1 12/12/2005 21:00:00 5.4 1.3 7.2 2.6 5.8 1.3 7.6 3.4 54 6 64 305 -11.9 0.2 -11.3 -12.1 12/12/2005 21:10:00 5.9 0.4 6.8 4.9 6.1 0.4 6.8 4.6 58 4 55 305 -11.9 0.1 -11.5 -12.1 12/12/2005 21:20:00 5.9 0.5 6.8 4.6 6.1 0.5 7.2 4.6 58 4 57 305 -12 0.1 -11.5 -12.3 12/12/2005 21:30:00 6.4 0.4 7.2 4.9 6.6 0.5 7.6 4.9 58 3 56 305 -12.2 0.1 -11.7 -12.5 12/12/2005 21:40:00 5.5 1 7.2 2.6 5.7 1 7.6 3 58 12 56 305 -12.3 0.2 -11.9 -12.5 12/12/2005 21:50:00 6 0.8 7.6 3.8 6 0.9 8.4 3.8 65 9 68 305 -12.4 0.2 -12.1 -12.7 12/12/2005 22:00:00 5.4 1 7.2 3 5.2 1 7.6 2.3 74 11 79 305 -12.5 0.1 -12.1 -12.9 12/12/2005 22:10:00 5.9 1.1 8 2.6 5.9 1.2 8.8 3 64 12 62 305 -12.8 0.1 -12.3 -13.1 12/12/2005 22:20:00 6.7 0.6 8 5.3 6.5 0.7 8 4.6 69 9 65 305 -13.1 0.1 -12.7 -13.5 12/12/2005 22:30:00 6.6 0.7 8.4 4.9 6.3 0.8 8.8 4.2 70 8 88 305 -13.3 0.1 -12.9 -13.7 12/12/2005 22:40:00 6.1 0.8 8 3 5.9 0.9 7.6 2.6 72 11 82 305 -13.5 0.1 -13.1 -13.7 12/12/2005 22:50:00 6 0.9 8 3.8 5.5 0.8 7.2 3 85 9 89 305 -13.7 0.1 -13.3 -14.1 12/12/2005 23:00:00 6.1 1 8.4 2.6 5.8 0.9 7.6 3.4 96 11 102 305 -13.9 0.1 -13.5 -14.3 12/12/2005 23:10:00 6.8 0.8 8.4 4.2 6.3 0.7 8 4.2 93 7 91 305 -14 0.1 -13.5 -14.3 12/12/2005 23:20:00 6.2 1 8 4.2 5.8 0.8 7.2 3.8 87 12 89 305 -14.1 0 -13.9 -14.3 12/12/2005 23:30:00 5.9 1 8.4 3.8 5.5 0.9 7.6 3.4 76 11 80 305 -14.2 0 -13.9 -14.3 12/12/2005 23:40:00 6.2 0.7 8 4.6 5.6 0.7 6.8 4.2 83 7 88 305 -14.2 0 -13.9 -14.4 12/12/2005 23:50:00 6 1 8.4 3.4 5.5 1 8.4 3.4 83 9 80 305 -14.3 0 -14.1 -14.4 12/13/2005 00:00:00 6.2 1.5 9.5 1.9 5.6 1.3 8.4 2.3 87 11 89 305 -14.3 0 -13.9 -14.4 12/13/2005 00:10:00 6.3 1 8.4 3.4 5.9 0.9 8 3.4 87 10 94 305 -14.2 0 -14.1 -14.3 12/13/2005 00:20:00 5.8 1.4 8.4 2.3 5.4 1.3 8 2.3 84 11 97 305 -14.2 0 -14.1 -14.4 12/13/2005 00:30:00 5.7 1 8 3 5.3 1 7.2 3 82 9 89 305 -14.1 0 -13.7 -14.3 12/13/2005 00:40:00 6 1 8 3.8 5.5 0.9 7.2 3.4 82 9 83 305 -13.9 0 -13.7 -14.3 12/13/2005 00:50:00 6 0.7 8 3.8 5.6 0.6 7.2 3.8 81 7 90 305 -13.7 0 -13.5 -13.9 12/13/2005 01:00:00 6.8 0.8 8.4 4.2 6.3 0.8 8.8 3 84 8 90 305 -13.6 0 -13.3 -13.7 12/13/2005 01:10:00 6.1 1 9.1 3.4 5.8 1 8.4 3.4 81 10 88 305 -13.6 0 -13.3 -13.7 12/13/2005 01:20:00 6.7 0.8 8.8 4.2 6.4 0.7 8 4.2 77 8 70 305 -13.5 0 -13.3 -13.7 12/13/2005 01:30:00 6.7 0.7 8 4.9 6.5 0.7 8.4 4.9 72 6 67 305 -13.5 0.1 -13.1 -13.7 12/13/2005 01:40:00 7.1 0.6 8.4 5.7 7 0.6 8.4 5.3 68 5 69 305 -13.4 0.2 -13.1 -13.7 12/13/2005 01:50:00 6.3 0.8 8.4 4.6 6.1 0.7 8 4.2 70 6 77 305 -13.5 0.1 -13.1 -13.7 12/13/2005 02:00:00 5.3 0.8 7.2 3.4 5 0.7 6.5 3 74 10 85 305 -13.6 0.1 -13.3 -13.7 12/13/2005 02:10:00 5.6 0.7 7.6 3.8 5.2 0.6 6.8 3.4 80 9 90 305 -13.6 0 -13.3 -13.7 12/13/2005 02:20:00 6.2 0.7 8 4.6 5.8 0.7 7.6 4.2 74 6 77 305 -13.6 0 -13.3 -13.9 12/13/2005 02:30:00 5.9 0.5 7.2 4.6 5.8 0.5 7.2 4.6 65 8 79 305 -13.6 0 -13.3 -13.7 12/13/2005 02:40:00 6.5 0.8 8.8 4.9 6.2 0.7 8 4.6 70 9 74 305 -13.7 0 -13.3 -13.9 12/13/2005 02:50:00 6.5 0.7 7.6 4.6 6.3 0.6 7.6 4.2 66 8 76 305 -13.8 0.1 -13.3 -14.1 12/13/2005 03:00:00 7.3 0.6 8.8 5.7 7.2 0.7 9.1 5.7 64 4 66 305 -13.7 0 -13.3 -14.1 12/13/2005 03:10:00 7.5 0.5 8.8 6.1 7.4 0.6 8.8 5.7 68 4 68 305 -13.8 0 -13.3 -14.1 12/13/2005 03:20:00 7.1 0.5 8.4 5.7 7 0.6 8.8 5.3 69 6 68 305 -13.7 0 -13.3 -14.1 12/13/2005 03:30:00 6.8 0.5 8 5.3 6.6 0.6 8.4 5.3 70 7 65 305 -13.7 0 -13.3 -13.9 12/13/2005 03:40:00 7.1 0.5 8.8 5.3 6.9 0.6 8.4 5.7 69 5 82 305 -13.6 0 -13.3 -13.7 12/13/2005 03:50:00 6.9 0.6 8.4 5.3 6.6 0.6 8 5.3 73 5 73 305 -13.8 0 -13.3 -13.9 12/13/2005 04:00:00 7.6 0.5 8.8 6.1 7.4 0.5 8.4 6.1 70 3 71 305 -13.8 0 -13.3 -14.1 12/13/2005 04:10:00 8.3 0.5 9.5 7.2 8.2 0.7 9.9 6.5 67 4 67 305 -14 0 -13.7 -14.3 12/13/2005 04:20:00 8.6 0.4 9.9 7.6 8.5 0.4 9.5 7.2 67 3 71 305 -14.1 0 -13.7 -14.3 12/13/2005 04:30:00 8.5 0.6 10.3 6.5 8.6 0.8 10.3 6.5 60 5 55 305 -14.1 0 -13.7 -14.3 12/13/2005 04:40:00 8.2 0.7 9.5 6.5 8.4 0.8 9.5 6.1 55 4 57 305 -14.2 0 -13.9 -14.3 12/13/2005 04:50:00 8.1 0.6 9.5 6.8 8.2 0.6 9.9 6.5 58 5 62 305 -14.2 0 -13.7 -14.3 12/13/2005 05:00:00 8 0.7 9.5 6.1 8 0.8 9.9 6.1 59 5 58 305 -14.2 0 -13.7 -14.3 12/13/2005 05:10:00 8.3 0.5 9.5 6.8 8.5 0.5 9.9 6.8 55 5 48 305 -14.3 0 -13.7 -14.4 12/13/2005 05:20:00 7.5 0.5 8.8 6.1 7.6 0.7 9.1 5.7 46 6 51 305 -14.3 0 -13.7 -14.4 12/13/2005 05:30:00 7.1 0.7 8.8 5.3 7.2 0.7 8.8 5.3 47 6 50 305 -14.2 0 -13.7 -14.4 12/13/2005 05:40:00 7.7 0.5 8.8 5.7 7.8 0.5 9.1 6.1 45 5 49 305 -14.4 0 -13.9 -14.6 12/13/2005 05:50:00 7.6 0.4 8.8 6.5 7.7 0.5 8.8 5.7 42 5 39 305 -14.4 0 -14.1 -14.6 12/13/2005 06:00:00 7.5 0.5 8.8 5.7 7.7 0.6 9.1 5.3 48 5 48 305 -14.4 0.1 -13.9 -14.6 12/13/2005 06:10:00 7.7 0.4 8.4 6.5 7.8 0.5 8.8 6.5 53 5 48 305 -14.4 0.1 -14.1 -14.6 12/13/2005 06:20:00 8.1 0.7 9.1 5.7 8.3 0.8 9.5 5.7 53 4 55 305 -14.4 0.1 -14.1 -14.6 12/13/2005 06:30:00 8.1 0.5 9.5 6.5 8.3 0.5 9.5 6.5 53 4 49 305 -14.5 0.1 -14.3 -14.6 12/13/2005 06:40:00 7.9 0.4 8.8 6.8 8 0.5 9.1 6.5 54 4 56 305 -14.5 0.1 -14.3 -14.6 12/13/2005 06:50:00 8.1 0.5 9.1 6.5 8.2 0.5 9.1 6.8 59 3 60 305 -14.5 0.1 -14.3 -14.6 12/13/2005 07:00:00 8 0.5 9.1 6.5 8.1 0.5 9.1 6.8 57 5 59 305 -14.5 0.1 -14.3 -14.6 12/13/2005 07:10:00 7.9 0.5 9.1 6.5 8 0.6 9.5 6.8 47 5 48 305 -14.4 0 -14.1 -14.6 12/13/2005 07:20:00 8.1 0.5 9.5 6.8 8.3 0.5 9.5 6.8 46 3 48 305 -14.4 0.1 -14.3 -14.6 12/13/2005 07:30:00 7.8 0.6 9.1 6.1 7.8 0.7 9.1 6.1 53 7 49 305 -14.4 0.1 -14.3 -14.6 12/13/2005 07:40:00 8.2 0.7 9.5 6.5 8.1 0.9 9.9 5.7 64 3 60 305 -14.7 0 -14.3 -14.8 12/13/2005 07:50:00 8 0.4 8.8 7.2 8.1 0.4 9.1 6.8 59 4 67 305 -14.6 0.1 -14.3 -14.6 12/13/2005 08:00:00 8.1 0.5 9.1 6.5 8.1 0.6 9.1 6.1 63 4 67 305 -14.6 0.1 -14.3 -14.8 12/13/2005 08:10:00 8 0.5 8.8 6.8 8.1 0.5 9.5 6.5 61 7 68 305 -14.7 0.1 -14.3 -14.8 12/13/2005 08:20:00 8.1 0.5 9.1 6.8 8.2 0.5 9.5 6.8 57 6 52 305 -14.6 0.1 -14.3 -14.6 12/13/2005 08:30:00 8.4 0.4 9.5 7.2 8.6 0.5 9.9 6.5 51 3 51 305 -14.6 0.1 -14.3 -14.6 12/13/2005 08:40:00 7.9 0.5 9.1 6.8 8.1 0.5 9.5 6.5 49 5 63 305 -14.5 0 -14.3 -14.6 12/13/2005 08:50:00 8 0.5 9.1 6.5 8.1 0.5 9.1 6.5 52 4 50 305 -14.5 0 -14.3 -14.6 12/13/2005 09:00:00 7.8 0.5 9.1 6.5 7.8 0.7 9.5 6.1 57 5 48 305 -14.4 0 -14.1 -14.6 12/13/2005 09:10:00 8.1 0.5 9.9 6.8 8 0.6 9.5 6.1 62 6 76 305 -14.4 0.1 -14.1 -14.6 12/13/2005 09:20:00 8.8 0.5 9.9 7.2 8.7 0.5 9.9 7.6 66 3 64 305 -14.6 0.1 -14.3 -14.6 12/13/2005 09:30:00 9 0.5 10.3 7.2 9 0.7 10.7 6.8 61 5 62 305 -14.7 0.1 -14.3 -14.6 12/13/2005 09:40:00 9.4 0.4 10.7 8.4 9.5 0.5 10.7 8 63 3 64 305 -14.7 0 -14.3 -14.6 12/13/2005 09:50:00 9.4 0.4 10.7 8.4 9.5 0.4 10.7 8 63 3 66 305 -14.7 0.1 -14.3 -14.8 12/13/2005 10:00:00 9.3 0.4 10.7 8.4 9.4 0.4 10.3 8 64 3 69 305 -14.6 0 -14.3 -14.6 12/13/2005 10:10:00 9.2 0.4 10.3 8 9.3 0.5 10.3 7.6 64 3 66 305 -14.7 0 -14.4 -14.6 12/13/2005 10:20:00 9.3 0.4 10.3 8.4 9.4 0.4 11.1 8.4 64 3 68 305 -14.7 0 -14.3 -14.6 12/13/2005 10:30:00 9.7 0.5 11.1 8.4 9.8 0.5 11.1 8.4 62 4 61 305 -14.6 0.1 -14.3 -14.6 12/13/2005 10:40:00 10 0.5 11.1 8.4 9.9 0.6 11.5 7.6 68 3 64 305 -14.6 0.1 -14.3 -14.6 12/13/2005 10:50:00 9.9 0.6 11.5 8 9.9 0.6 11.5 8 62 4 61 305 -14.4 0 -14.1 -14.6 12/13/2005 11:00:00 10.3 0.4 11.5 9.1 10.3 0.4 11.1 8.8 65 2 67 305 -14.4 0.1 -14.3 -14.6 12/13/2005 11:10:00 10.2 0.5 11.5 8.4 10.1 0.7 11.5 8 67 3 64 305 -14.4 0.1 -14.1 -14.6 12/13/2005 11:20:00 10.3 0.5 11.8 8.4 10.1 0.7 11.5 8 67 3 70 305 -14.4 0 -14.1 -14.6 12/13/2005 11:30:00 10.4 0.5 11.8 9.1 10.1 0.6 11.5 8.8 69 4 68 305 -14.4 0 -14.1 -14.6 12/13/2005 11:40:00 10.3 0.5 11.1 8.8 9.9 0.6 11.1 8 73 2 75 305 -14.4 0 -14.1 -14.6 12/13/2005 11:50:00 10 0.4 11.1 8.8 9.6 0.5 11.1 8.4 74 3 72 305 -14.4 0 -13.9 -14.6 12/13/2005 12:00:00 9.5 0.4 10.7 8 9.3 0.5 10.3 7.6 72 3 74 305 -14.3 0.1 -13.9 -14.4 12/13/2005 12:10:00 8.8 0.6 10.3 7.6 8.6 0.6 10.3 7.2 70 4 73 305 -14.3 0 -13.7 -14.4 12/13/2005 12:20:00 8.2 0.5 9.1 6.8 8.3 0.6 9.5 6.5 60 6 67 305 -14.1 0.1 -13.7 -14.3 12/13/2005 12:30:00 8.2 0.4 9.1 6.8 8.4 0.5 9.5 6.5 54 4 50 305 -14.2 0.1 -13.7 -14.3 12/13/2005 12:40:00 8 0.6 9.5 6.5 8.2 0.7 9.9 6.5 56 4 56 305 -14.1 0.1 -13.7 -14.3 12/13/2005 12:50:00 8.8 0.6 10.3 7.2 8.8 0.7 10.7 6.5 61 5 56 305 -14.1 0.1 -13.7 -14.3 12/13/2005 13:00:00 9.1 0.5 10.3 7.6 9.2 0.6 10.7 7.2 57 5 60 305 -14 0.1 -13.7 -14.3 12/13/2005 13:10:00 9.3 0.7 11.1 7.2 9.3 0.9 11.1 6.8 57 5 59 305 -13.9 0.1 -13.5 -14.3 12/13/2005 13:20:00 10.4 0.5 11.5 8.8 10.3 0.7 11.8 8 66 4 70 305 -14 0.1 -13.5 -14.3 12/13/2005 13:30:00 10 0.5 11.1 8.4 10.2 0.6 11.5 8.4 56 5 67 305 -13.9 0 -13.3 -14.1 12/13/2005 13:40:00 9.1 0.7 10.7 7.2 9.3 0.7 11.1 7.6 55 4 50 305 -13.8 0 -13.3 -14.1 12/13/2005 13:50:00 8.3 0.7 9.5 6.5 8.5 0.8 9.9 6.1 54 4 57 305 -13.7 0 -13.1 -13.7 12/13/2005 14:00:00 8 0.7 9.5 6.5 8.1 0.7 9.9 6.1 51 5 46 305 -13.6 0.1 -13.1 -13.7 12/13/2005 14:10:00 8.1 0.8 9.9 6.5 8.2 0.8 10.3 6.5 48 7 54 305 -13.5 0.1 -12.9 -13.7 12/13/2005 14:20:00 8.1 0.7 9.9 6.5 8.2 0.8 10.3 6.1 47 6 52 305 -13.6 0 -13.1 -13.7 12/13/2005 14:30:00 8.9 0.8 11.1 6.8 8.8 0.9 11.1 7.2 47 5 43 305 -13.6 0 -13.1 -13.7 12/13/2005 14:40:00 8.9 0.9 11.1 6.5 8.9 0.9 11.5 6.5 47 6 49 305 -13.5 0.1 -12.9 -13.7 12/13/2005 14:50:00 10 1.1 12.2 7.2 10.2 1.2 13 7.2 47 5 50 305 -13.4 0.1 -12.9 -13.7 12/13/2005 15:00:00 10.6 0.9 12.6 8 10.8 1 12.6 8.4 49 5 54 305 -13.4 0.1 -12.9 -13.5 12/13/2005 15:10:00 9.9 1 12.6 7.6 10 1.1 12.6 6.8 49 5 46 305 -13.3 0.1 -12.9 -13.5 12/13/2005 15:20:00 9 0.9 11.1 6.8 9.1 1 11.8 6.5 49 6 46 305 -13.2 0.1 -12.9 -13.5 12/13/2005 15:30:00 8.5 0.8 9.9 6.5 8.5 0.9 10.7 6.1 50 6 45 305 -13.2 0.1 -12.9 -13.5 12/13/2005 15:40:00 8.8 0.8 11.1 6.8 8.8 0.9 11.1 6.5 53 5 56 305 -13.4 0.1 -12.9 -13.7 12/13/2005 15:50:00 8.8 0.8 10.3 6.5 8.8 0.8 10.3 6.5 50 5 52 305 -13.4 0.1 -12.9 -13.7 12/13/2005 16:00:00 8.3 0.9 10.7 6.1 8.3 0.9 10.7 6.1 50 6 53 305 -13.4 0.1 -12.9 -13.7 12/13/2005 16:10:00 8.1 0.9 10.3 5.7 8.1 1 10.3 5.7 55 7 53 305 -13.2 0.1 -12.7 -13.5 12/13/2005 16:20:00 10.1 1.3 13 6.8 9.9 1.4 13.7 6.8 64 7 57 305 -13.1 0.1 -12.5 -13.5 12/13/2005 16:30:00 10.5 0.8 12.2 8.4 10.3 0.9 12.6 8.4 66 5 66 305 -13.5 0.1 -12.9 -13.9 12/13/2005 16:40:00 10.6 0.8 13 8.8 10.3 0.8 13 8.8 66 4 59 305 -13.8 0.1 -13.3 -14.1 12/13/2005 16:50:00 10.5 0.8 12.6 8.8 10.4 0.8 12.6 8.4 65 5 64 305 -13.9 0.1 -13.5 -14.1 12/13/2005 17:00:00 12.5 0.8 14.9 10.3 12.3 0.9 14.5 9.5 67 3 67 305 -14 0.2 -13.5 -14.3 12/13/2005 17:10:00 10.2 1.7 13.3 6.5 10.1 1.9 13.7 6.1 62 6 65 305 -14 0.2 -13.7 -14.3 12/13/2005 17:20:00 10.1 1 13.7 7.6 10 1.2 14.1 6.8 62 6 67 305 -14.1 0.1 -13.5 -14.4 12/13/2005 17:30:00 12.3 1.1 15.3 10.3 12.2 1.1 14.9 9.5 66 4 70 305 -14.4 0.1 -13.7 -14.6 12/13/2005 17:40:00 11.2 0.8 14.1 8.8 11.1 0.8 13 9.1 64 4 71 305 -14.5 0 -14.1 -14.6 12/13/2005 17:50:00 11.4 1 14.9 9.1 11.3 1.1 13.7 8.8 64 5 67 305 -14.6 0.1 -14.3 -14.8 12/13/2005 18:00:00 13.7 0.8 16.1 11.5 13.6 1 16.4 11.1 66 3 66 305 -14.8 0 -14.4 -15 12/13/2005 18:10:00 14.2 0.8 16.1 12.2 14.1 0.9 16.4 11.1 66 3 73 305 -14.8 0 -14.4 -15 12/13/2005 18:20:00 15.1 0.9 17.2 13 14.8 1 17.2 11.8 68 3 67 305 -14.9 0 -14.6 -15 12/13/2005 18:30:00 15.2 0.9 17.2 12.6 15 1 17.6 12.2 66 3 66 305 -14.9 0 -14.4 -15 12/13/2005 18:40:00 14.5 1 17.2 11.8 14.4 1 16.8 11.8 66 4 62 305 -14.9 0 -14.4 -15 12/13/2005 18:50:00 14.5 1.1 16.8 11.5 14.4 1.1 16.4 11.5 66 4 67 305 -14.9 0 -14.4 -15 12/13/2005 19:00:00 13.8 0.9 16.4 11.5 13.7 1 16.4 11.1 66 4 62 305 -14.9 0 -14.4 -15 12/13/2005 19:10:00 15 1.3 17.9 11.5 14.6 1.3 17.6 11.1 70 4 71 305 -14.9 0 -14.4 -15 12/13/2005 19:20:00 15.6 1 17.9 12.6 15.1 1.2 17.6 11.1 72 4 72 305 -14.6 0.1 -14.3 -14.6 12/13/2005 19:30:00 15.5 1.1 17.9 13 15 1.1 18.3 12.6 71 4 69 305 -14.4 0 -14.1 -14.6 12/13/2005 19:40:00 13.4 0.9 16.1 11.5 13.2 0.9 15.3 10.7 68 4 67 305 -14.5 0.1 -14.3 -14.6 12/13/2005 19:50:00 15.3 1 18.3 12.6 15 1.1 17.9 12.2 68 4 68 305 -14.4 0.1 -14.1 -14.6 12/13/2005 20:00:00 14 1.1 16.8 11.1 13.9 1.2 16.4 10.3 64 5 70 305 -14.4 0.1 -14.1 -14.6 12/13/2005 20:10:00 12.8 1.1 15.6 9.9 12.8 1.1 15.6 9.5 58 5 61 305 -14.3 0.1 -13.9 -14.6 12/13/2005 20:20:00 12.9 1.2 16.1 10.3 12.9 1.3 16.1 9.9 57 5 57 305 -14.2 0.1 -13.9 -14.4 12/13/2005 20:30:00 12.9 1.1 15.6 10.3 12.9 1.2 15.3 10.3 57 5 76 305 -14.2 0 -13.9 -14.4 12/13/2005 20:40:00 12.7 1 14.9 10.3 12.6 1 15.3 9.9 55 5 48 305 -14.1 0.1 -13.7 -14.3 12/13/2005 20:50:00 12.5 1 15.3 9.9 12.4 1 15.6 9.5 52 5 54 305 -14 0.1 -13.7 -14.3 12/13/2005 21:00:00 12.4 1 14.9 9.5 12.3 1.1 14.9 9.5 50 5 51 305 -13.9 0.1 -13.5 -14.3 12/13/2005 21:10:00 12.7 1 16.1 10.7 12.5 1.1 16.1 9.9 51 5 51 305 -13.7 0.1 -13.3 -13.9 12/13/2005 21:20:00 11.6 1 14.1 8.4 11.5 1.1 14.5 8.4 50 5 45 305 -13.6 0.1 -13.1 -13.7 12/13/2005 21:30:00 11.9 1.1 15.3 8.8 11.8 1.1 14.9 9.1 51 5 48 305 -13.5 0.1 -13.1 -13.7 12/13/2005 21:40:00 12.3 1.1 14.9 9.1 12.1 1.2 14.5 9.1 50 5 50 305 -13.5 0.1 -13.1 -13.7 12/13/2005 21:50:00 12 1 14.9 9.9 11.9 1.1 15.3 9.5 52 5 50 305 -13.4 0.1 -12.9 -13.7 12/13/2005 22:00:00 12.6 1.2 15.6 9.9 12.5 1.2 15.6 9.9 52 5 55 305 -13.4 0.1 -12.9 -13.7 12/13/2005 22:10:00 12.6 1 15.3 10.3 12.5 1 14.9 9.9 52 5 56 305 -13.4 0.1 -12.9 -13.7 12/13/2005 22:20:00 11.8 1 14.5 9.9 11.6 1.1 14.5 9.1 47 5 45 305 -13.4 0 -12.9 -13.5 12/13/2005 22:30:00 12 1.2 14.9 9.1 11.9 1.3 15.3 8.8 47 6 41 305 -13.4 0.1 -12.9 -13.7 12/13/2005 22:40:00 12.1 1.1 15.3 9.1 11.9 1.2 15.3 9.1 47 6 43 305 -13.2 0 -12.7 -13.3 12/13/2005 22:50:00 12.5 1.3 16.1 9.5 12.6 1.3 15.6 9.5 44 6 44 305 -13.1 0 -12.7 -13.3 12/13/2005 23:00:00 13 1.5 16.1 9.1 12.7 1.5 16.4 9.1 41 5 40 305 -13.3 0.1 -12.7 -13.5 12/13/2005 23:10:00 11.9 1.4 15.3 8.8 11.7 1.3 14.9 8.4 38 6 39 305 -13.3 0 -12.9 -13.5 12/13/2005 23:20:00 13 1.5 16.4 9.1 12.8 1.5 16.1 8.8 41 6 48 305 -13.3 0.1 -12.9 -13.5 12/13/2005 23:30:00 12.5 1.5 16.1 8.8 12.4 1.6 16.4 9.1 40 7 39 305 -13.4 0 -12.9 -13.5 12/13/2005 23:40:00 13.5 1.4 16.8 9.9 13.3 1.5 16.8 9.9 40 6 35 305 -13.3 0.1 -12.9 -13.5 12/13/2005 23:50:00 13 2 17.9 8 12.7 2 17.6 8 41 6 43 305 -13.4 0.1 -12.9 -13.5 12/14/2005 00:00:00 12.8 1.4 17.6 9.1 12.6 1.5 17.2 8.8 39 6 35 305 -13.4 0.1 -12.9 -13.5 12/14/2005 00:10:00 12.4 1.9 19.1 8.4 12.2 2.1 18.3 8.4 37 6 49 305 -13.5 0.1 -13.1 -13.7 12/14/2005 00:20:00 13.8 1.7 18.3 9.9 13.7 1.8 17.9 9.5 39 6 37 305 -13.7 0.1 -13.3 -13.9 12/14/2005 00:30:00 14.2 1.7 17.9 10.3 14 1.7 18.3 9.1 37 6 42 305 -13.7 0.1 -13.3 -14.1 12/14/2005 00:40:00 13.5 1.7 17.6 9.5 13.4 1.8 17.9 9.1 39 6 41 305 -13.6 0.1 -13.1 -13.9 12/14/2005 00:50:00 13.1 1.7 17.2 9.9 13 1.8 17.2 8.8 38 6 36 305 -13.6 0.1 -13.1 -13.9 12/14/2005 01:00:00 13 1.2 16.4 10.3 12.7 1.3 17.2 10.3 35 6 30 305 -13.7 0.1 -13.3 -13.9 12/14/2005 01:10:00 14.5 1.5 17.6 10.7 14.3 1.7 18.3 9.9 34 5 35 305 -13.8 0.1 -13.3 -14.1 12/14/2005 01:20:00 14.4 1.3 17.2 10.3 14.2 1.4 17.2 10.3 35 5 36 305 -13.8 0.1 -13.3 -14.1 12/14/2005 01:30:00 14.1 1.4 17.6 10.3 14 1.5 17.9 9.9 35 5 35 305 -13.6 0.1 -13.3 -13.9 12/14/2005 01:40:00 14.6 1.5 17.9 10.7 14.4 1.4 17.6 10.7 35 5 32 305 -13.6 0.1 -13.3 -13.9 12/14/2005 01:50:00 14.5 1.5 18.3 11.1 14.3 1.5 18.3 11.1 35 6 28 305 -13.6 0.1 -13.3 -14.1 12/14/2005 02:00:00 14.2 1.3 17.9 11.1 14 1.4 17.2 10.7 36 6 37 305 -13.8 0.1 -13.3 -14.3 12/14/2005 02:10:00 14.2 1.6 18.7 9.9 14 1.7 19.1 10.3 36 6 32 305 -14 0.1 -13.7 -14.3 12/14/2005 02:20:00 13.3 1.6 17.2 8.4 13.3 1.6 17.6 9.1 38 6 40 305 -14 0.1 -13.7 -14.3 12/14/2005 02:30:00 12.7 1.7 17.9 8.8 12.6 1.6 17.2 8.8 37 7 33 305 -14.1 0.1 -13.7 -14.3 12/14/2005 02:40:00 13.2 1.9 18.3 9.1 13.1 2 17.6 8.8 38 6 45 305 -14.3 0 -13.7 -14.4 12/14/2005 02:50:00 13.9 1.5 17.9 9.9 13.8 1.5 18.7 10.7 39 6 42 305 -14.4 0 -14.1 -14.6 12/14/2005 03:00:00 13.3 1.5 16.8 9.9 13.1 1.7 17.6 9.9 37 6 31 305 -14.4 0 -13.9 -14.6 12/14/2005 03:10:00 14.2 1.7 17.9 10.3 13.9 1.7 17.6 9.5 38 6 39 305 -14.4 0 -14.1 -14.6 12/14/2005 03:20:00 14 1.7 19.1 10.3 13.7 1.7 18.3 10.3 39 6 50 305 -14.4 0 -14.3 -14.4 12/14/2005 03:30:00 13.9 1.6 19.1 10.3 13.6 1.7 17.9 9.9 41 6 35 305 -14.4 0 -14.3 -14.6 12/14/2005 03:40:00 15.2 1.6 19.5 9.9 15.1 1.5 18.7 10.3 41 6 38 305 -14.4 0 -14.3 -14.6 12/14/2005 03:50:00 14 2.2 20.2 10.3 13.9 2 19.5 9.1 39 6 36 305 -14.5 0 -14.3 -14.6 12/14/2005 04:00:00 13.9 2.3 20.2 9.1 13.7 2.2 19.1 8.8 38 7 42 305 -14.5 0.1 -14.3 -14.6 12/14/2005 04:10:00 14.7 1.9 19.1 9.9 14.4 1.8 19.1 10.3 39 6 32 305 -14.5 0.1 -14.1 -14.6 12/14/2005 04:20:00 15 1.9 20.2 10.3 14.6 1.9 20.2 9.9 38 7 42 305 -14.5 0 -14.3 -14.6 12/14/2005 04:30:00 14.2 1.8 19.1 9.1 14.1 1.7 17.9 9.1 38 6 32 305 -14.5 0.1 -14.3 -14.6 12/14/2005 04:40:00 14.3 1.6 18.3 9.9 14 1.6 18.7 9.9 37 6 37 305 -14.6 0.1 -14.1 -14.6 12/14/2005 04:50:00 14.7 2.1 19.5 9.5 14.3 1.9 18.7 9.5 38 7 34 305 -14.5 0.2 -14.3 -14.6 12/14/2005 05:00:00 15.6 2.2 19.9 9.9 15.2 2.1 19.9 9.9 37 7 53 305 -14.5 0.2 -14.3 -14.6 12/14/2005 05:10:00 15.1 2.1 20.2 9.5 14.7 2 20.2 9.1 36 6 37 305 -14.5 0.2 -14.1 -14.6 12/14/2005 05:20:00 14.7 2.3 20.6 9.9 14.4 2.2 20.2 9.9 35 6 34 305 -14.5 0.2 -14.3 -14.6 12/14/2005 05:30:00 14.7 2 19.1 10.3 14.2 2 19.1 9.9 34 6 42 305 -14.4 0.1 -14.1 -14.6 12/14/2005 05:40:00 14.4 2.5 20.6 8.8 13.9 2.5 19.9 8.4 34 7 37 305 -14.4 0.1 -14.1 -14.6 12/14/2005 05:50:00 15.5 1.9 20.2 11.5 15.3 2 19.9 11.5 34 6 33 305 -14.5 0.1 -14.1 -14.6 12/14/2005 06:00:00 15.9 2.1 21.4 10.7 15.4 2.1 21.4 11.1 34 6 37 305 -14.6 0.1 -14.3 -14.6 12/14/2005 06:10:00 15.9 1.9 19.9 11.1 15.6 1.8 19.5 11.1 34 6 33 305 -14.6 0.1 -14.3 -14.6 12/14/2005 06:20:00 14.1 1.9 19.1 9.9 13.7 1.8 18.3 9.1 35 7 38 305 -14.6 0.1 -14.3 -14.6 12/14/2005 06:30:00 15.1 1.8 20.6 9.9 14.7 1.7 19.1 9.9 35 7 27 305 -14.6 0.1 -14.3 -14.8 12/14/2005 06:40:00 15.7 2.4 21 11.1 15.2 2.4 20.6 9.5 37 6 33 305 -14.6 0.1 -14.3 -15 12/14/2005 06:50:00 15 2.1 21.4 9.9 14.7 2.1 21 10.3 36 6 41 305 -14.6 0.1 -14.3 -14.6 12/14/2005 07:00:00 16.4 2.4 21 10.7 16 2.4 20.6 10.3 34 6 32 305 -14.6 0.1 -14.3 -14.6 12/14/2005 07:10:00 16.1 1.9 19.9 10.7 15.7 1.8 20.2 10.7 35 7 47 305 -14.7 0 -14.3 -14.6 12/14/2005 07:20:00 16 2.1 21 11.5 15.7 2.1 20.2 10.7 33 6 36 305 -14.7 0 -14.4 -14.6 12/14/2005 07:30:00 15.9 1.8 19.9 11.5 15.4 1.8 19.9 11.1 34 6 35 305 -14.7 0 -14.4 -14.6 12/14/2005 07:40:00 16.5 2.2 21.8 11.8 16.1 2.1 21 11.8 35 6 32 305 -14.6 0.1 -14.3 -14.6 12/14/2005 07:50:00 16.3 2 21.8 12.2 16 1.9 22.1 11.5 34 6 37 305 -14.4 0 -14.3 -14.6 12/14/2005 08:00:00 16.8 2.2 22.6 11.8 16.4 2.2 21.8 11.1 37 6 34 305 -14.5 0.1 -13.9 -14.6 12/14/2005 08:10:00 15.6 2.6 21 9.9 15.2 2.5 21 9.1 35 6 35 305 -14.4 0 -14.1 -14.6 12/14/2005 08:20:00 16.5 2.2 21.8 12.2 16.1 2.2 21.8 11.1 35 6 35 305 -14.3 0 -13.9 -14.6 12/14/2005 08:30:00 16 1.9 20.2 11.5 15.4 1.7 20.2 11.1 35 6 35 305 -14.2 0 -13.9 -14.4 12/14/2005 08:40:00 16.3 1.9 21.4 11.8 15.9 1.8 19.9 11.8 37 6 32 305 -14.1 0.1 -13.7 -14.3 12/14/2005 08:50:00 15.6 2 19.9 10.7 15.1 1.9 19.5 10.3 35 6 33 305 -14 0 -13.7 -14.3 12/14/2005 09:00:00 16.6 1.7 20.2 12.2 16.1 1.7 20.2 11.1 33 6 33 305 -14 0.1 -13.5 -14.3 12/14/2005 09:10:00 15.1 1.8 20.6 10.7 14.9 1.7 20.6 10.3 35 7 34 305 -14 0 -13.7 -14.3 12/14/2005 09:20:00 15.4 2.2 20.2 11.1 15 2.1 19.9 10.7 34 7 25 305 -13.9 0.1 -13.3 -14.1 12/14/2005 09:30:00 16.6 1.9 21 11.5 16.2 1.8 20.2 11.8 35 7 31 305 -14 0.2 -13.5 -14.3 12/14/2005 09:40:00 15 1.7 19.1 11.1 14.7 1.7 18.7 10.3 36 6 37 305 -13.9 0.2 -13.3 -14.3 12/14/2005 09:50:00 15.2 1.7 19.5 11.1 15.1 1.7 19.5 11.1 36 6 31 305 -14 0.1 -13.5 -14.3 12/14/2005 10:00:00 15.2 1.7 19.9 10.7 14.9 1.7 18.7 10.3 36 6 30 305 -13.8 0.1 -13.3 -14.3 12/14/2005 10:10:00 15.1 2.2 21 9.5 14.9 2.1 19.9 9.5 39 6 39 305 -13.7 0.1 -13.3 -14.1 12/14/2005 10:20:00 16.8 1.7 21.8 11.8 16.5 1.6 21.8 13 40 7 43 305 -13.7 0.1 -13.3 -13.7 12/14/2005 10:30:00 15.8 1.7 19.9 11.5 15.7 1.7 20.2 11.5 41 7 45 305 -13.5 0.2 -13.1 -13.7 12/14/2005 10:40:00 15.6 2.3 22.1 10.3 15.2 2.3 21 10.7 40 7 43 305 -13.5 0.1 -13.1 -13.7 12/14/2005 10:50:00 16 2.6 21.4 10.7 15.7 2.6 21 10.3 38 7 38 305 -13.5 0.2 -13.1 -13.7 12/14/2005 11:00:00 15.6 2.1 20.6 10.7 15.3 2.1 20.6 9.9 37 7 39 305 -13.5 0.2 -13.1 -13.7 12/14/2005 11:10:00 15.4 1.6 20.2 11.5 15 1.7 19.5 11.5 40 7 32 305 -13.5 0.2 -13.1 -13.7 12/14/2005 11:20:00 16.3 2.4 21.4 10.3 16 2.4 22.1 10.7 40 7 44 305 -13.6 0.1 -13.1 -13.7 12/14/2005 11:30:00 16.7 2.1 21.8 11.5 16.3 2.1 21.4 10.7 41 7 49 305 -13.6 0.1 -13.1 -13.7 12/14/2005 11:40:00 15.7 2.4 21.4 10.7 15.4 2.4 21 10.3 43 6 48 305 -13.7 0 -13.3 -13.7 12/14/2005 11:50:00 16.4 1.9 20.2 11.8 16 2.1 20.6 11.1 42 7 53 305 -13.6 0 -13.3 -13.7 12/14/2005 12:00:00 15.7 2.1 21 9.9 15.4 2 20.2 10.3 43 7 39 305 -13.6 0 -13.1 -13.7 12/14/2005 12:10:00 15.9 2.1 21.4 10.7 15.8 2.1 22.1 11.1 44 6 38 305 -13.5 0.1 -13.1 -13.7 12/14/2005 12:20:00 17 2.4 22.1 11.1 16.7 2.3 22.1 9.5 44 6 51 305 -13.5 0 -13.3 -13.7 12/14/2005 12:30:00 15.5 2 21 10.3 15.3 1.9 20.2 10.7 43 7 46 305 -13.4 0 -13.1 -13.7 12/14/2005 12:40:00 16.2 1.7 21.4 11.1 15.8 1.6 20.6 11.1 42 7 42 305 -13.4 0 -13.1 -13.5 12/14/2005 12:50:00 17.2 2 22.1 11.8 16.9 2 21.8 13 42 6 39 305 -13.2 0 -12.9 -13.5 12/14/2005 13:00:00 16.3 2.1 21.4 11.1 16 2.1 21.4 11.5 43 6 45 305 -13.2 0 -12.7 -13.3 12/14/2005 13:10:00 15.3 1.8 20.2 11.1 15.2 1.9 19.9 10.7 44 7 47 305 -13.2 0 -12.9 -13.3 12/14/2005 13:20:00 16.3 1.8 21.4 11.8 16.1 1.8 21.4 11.8 43 7 42 305 -13.2 0 -12.9 -13.3 12/14/2005 13:30:00 15.7 1.5 20.2 12.6 15.6 1.5 19.5 12.2 45 6 35 305 -13.1 0 -12.9 -13.3 12/14/2005 13:40:00 17 1.8 21 12.6 16.6 1.9 20.6 11.5 43 6 40 305 -13.1 0 -12.7 -13.3 12/14/2005 13:50:00 15.6 1.7 19.1 11.5 15.3 1.7 19.5 11.8 42 6 46 305 -13.1 0 -12.7 -13.3 12/14/2005 14:00:00 16.5 1.9 22.1 12.2 16.4 2 21.8 11.8 46 6 38 305 -13 0.1 -12.5 -13.3 12/14/2005 14:10:00 16.2 2.3 22.1 11.5 16 2.2 21.8 11.5 47 6 53 305 -12.9 0.2 -12.5 -13.1 12/14/2005 14:20:00 16.1 1.7 19.9 11.1 15.9 1.7 19.9 11.5 42 6 40 305 -12.9 0.1 -12.5 -13.1 12/14/2005 14:30:00 16.2 2.1 21.4 11.1 16.1 2.1 21.4 11.8 42 5 42 305 -12.9 0.2 -12.5 -13.1 12/14/2005 14:40:00 17.1 1.9 21.8 11.8 16.8 1.9 21.4 11.8 40 6 41 305 -12.9 0.2 -12.5 -13.1 12/14/2005 14:50:00 16.6 1.8 21.4 10.3 16.4 1.7 20.2 11.5 41 6 43 305 -12.9 0.2 -12.5 -13.1 12/14/2005 15:00:00 17.3 1.7 21.8 12.6 17 1.7 22.1 11.1 44 6 44 305 -12.8 0.1 -12.3 -12.9 12/14/2005 15:10:00 16.1 2.2 21.8 11.1 15.9 2.2 21.4 11.1 42 6 41 305 -12.7 0.1 -12.3 -12.9 12/14/2005 15:20:00 16.5 1.8 21.4 11.8 16.1 1.9 20.6 10.7 40 6 39 305 -12.9 0.1 -12.5 -13.1 12/14/2005 15:30:00 17.3 2.2 21.4 12.6 17.1 2.1 21.8 11.8 41 6 48 305 -12.9 0.2 -12.5 -13.3 12/14/2005 15:40:00 18 2.1 22.1 12.2 17.7 2.1 22.1 12.2 42 6 38 305 -13 0.2 -12.5 -13.3 12/14/2005 15:50:00 18.2 2.1 22.6 13 17.8 2.2 22.6 12.6 41 6 44 305 -12.9 0.2 -12.5 -13.1 12/14/2005 16:00:00 17.3 2.2 22.9 11.8 17 2.3 23.3 11.5 43 6 41 305 -12.8 0.1 -12.3 -13.1 12/14/2005 16:10:00 18 2.6 24 11.8 17.6 2.5 23.7 11.1 42 6 48 305 -12.7 0.1 -12.3 -12.9 12/14/2005 16:20:00 18.3 2 23.3 13 18.1 1.9 22.9 13 42 6 46 305 -12.7 0 -12.5 -12.9 12/14/2005 16:30:00 19.1 2.1 23.3 13.3 18.7 2 23.7 13.3 41 6 41 305 -12.7 0 -12.5 -12.9 12/14/2005 16:40:00 19.4 2 23.3 13.7 19.3 2.1 23.7 14.1 42 6 37 305 -12.7 0 -12.5 -12.9 12/14/2005 16:50:00 16.3 2.3 21 11.1 16.1 2.2 21 10.7 39 6 32 305 -12.6 0 -12.3 -12.7 12/14/2005 17:00:00 16.8 2.2 21.8 10.3 16.5 2.2 22.9 10.3 40 6 29 305 -12.6 0 -12.1 -12.9 12/14/2005 17:10:00 17.4 2 22.1 13.7 17 1.9 21.8 13 41 7 41 305 -12.6 0 -12.5 -12.9 12/14/2005 17:20:00 16.5 1.8 21.4 12.2 16.1 1.7 20.6 11.8 38 6 33 305 -12.6 0 -12.1 -12.9 12/14/2005 17:30:00 17.5 2.1 22.6 11.5 17.2 2 22.1 12.2 38 6 30 305 -12.7 0 -12.3 -12.9 12/14/2005 17:40:00 16.6 2 21 12.2 16.3 1.9 22.6 11.5 36 6 37 305 -12.9 0 -12.5 -13.1 12/14/2005 17:50:00 18.8 2.3 23.3 13 18.5 2.4 24 13.3 37 6 40 305 -13.1 0 -12.7 -13.3 12/14/2005 18:00:00 17.8 2.4 24.4 11.8 17.5 2.4 24 11.1 38 7 27 305 -13.4 0.1 -12.9 -13.7 12/14/2005 18:10:00 18.8 2.3 24.4 13.3 18.4 2.3 24.4 13 35 6 37 305 -13.5 0.1 -13.1 -13.7 12/14/2005 18:20:00 20.7 2.4 26.8 14.5 20.1 2.5 26 13.7 37 6 29 305 -13.7 0 -13.3 -13.7 12/14/2005 18:30:00 19.2 2.4 25.6 13.3 18.8 2.4 25.2 13 37 6 31 305 -13.7 0 -13.3 -13.9 12/14/2005 18:40:00 15.2 2.7 23.3 8 14.8 2.6 21.8 8 34 8 32 305 -13.7 0.1 -13.3 -14.1 12/14/2005 18:50:00 16.1 2.2 22.9 10.7 15.7 2.1 21.8 11.8 37 7 34 305 -14 0.1 -13.5 -14.3 12/14/2005 19:00:00 17 2.5 22.6 12.2 16.4 2.3 22.1 11.5 36 7 27 305 -14.1 0.1 -13.7 -14.3 12/14/2005 19:10:00 17.9 2.7 24 11.5 17.7 2.4 23.7 12.2 35 7 19 305 -14.2 0.1 -13.7 -14.6 12/14/2005 19:20:00 20.2 2.2 25.2 14.5 19.7 2.2 25.2 14.1 33 6 30 305 -14.4 0.1 -14.1 -14.6 12/14/2005 19:30:00 22.9 2.5 29.4 16.1 22.1 2.5 27.9 14.5 32 6 30 305 -14.6 0.1 -14.3 -14.6 12/14/2005 19:40:00 22.1 2.3 27.9 15.6 21.5 2.2 27.1 16.4 33 6 35 305 -14.6 0.1 -14.3 -14.6 12/14/2005 19:50:00 19.9 2.7 26.8 13.3 19.4 2.6 25.2 13 37 6 30 305 -14.7 0 -14.3 -14.6 12/14/2005 20:00:00 18.7 2.8 25.6 11.5 18.1 2.7 26 11.5 37 7 37 305 -14.5 0.1 -14.3 -14.6 12/14/2005 20:10:00 17.8 2.6 24 12.6 17.6 2.5 24 11.8 35 7 31 305 -14.4 0 -14.1 -14.6 12/14/2005 20:20:00 18 2.5 23.7 12.6 17.5 2.4 23.7 11.5 34 6 47 305 -14.4 0 -14.3 -14.6 12/14/2005 20:30:00 18.4 2.5 24 11.5 18 2.2 22.9 12.6 32 6 34 305 -14.4 0 -14.1 -14.6 12/14/2005 20:40:00 18.1 2.2 23.7 12.6 17.7 2.1 22.9 12.2 34 7 35 305 -14.4 0 -14.1 -14.6 12/14/2005 20:50:00 18.1 2.9 24 10.3 17.6 2.8 23.7 10.7 35 6 32 305 -14.4 0 -14.1 -14.6 12/14/2005 21:00:00 17.4 2.4 23.7 11.5 17.1 2.4 23.7 11.1 34 6 30 305 -14.3 0 -13.9 -14.4 12/14/2005 21:10:00 18.5 2.1 22.9 12.2 17.9 2 22.9 11.8 33 7 23 305 -14.3 0 -13.9 -14.4 12/14/2005 21:20:00 19.9 2.5 26 14.5 19.5 2.4 25.6 14.5 33 6 38 305 -14.4 0 -14.3 -14.6 12/14/2005 21:30:00 18.9 2.5 26 13.3 18.3 2.5 24.8 13 33 6 34 305 -14.4 0 -14.3 -14.6 12/14/2005 21:40:00 18.4 2.2 24 13.3 17.8 2.2 23.7 12.6 31 6 28 305 -14.4 0 -14.1 -14.6 12/14/2005 21:50:00 18.9 2.1 23.7 14.1 18.4 2.1 23.7 13.3 32 6 23 305 -14.4 0 -14.1 -14.6 12/14/2005 22:00:00 17.7 2.2 23.7 12.2 17.3 2.1 23.7 11.8 34 7 36 305 -14.4 0 -14.1 -14.6 12/14/2005 22:10:00 19.2 2.3 24.8 13.7 18.7 2.3 24.4 13 34 6 28 305 -14.3 0 -13.9 -14.4 12/14/2005 22:20:00 19.2 2.4 24.8 13.7 18.8 2.2 23.7 13.3 32 6 30 305 -14.4 0 -14.3 -14.6 12/14/2005 22:30:00 19.2 1.9 24 14.1 18.6 1.9 24 14.1 32 6 29 305 -14.4 0 -14.3 -14.6 12/14/2005 22:40:00 18.9 2.1 24.4 14.1 18.4 2.1 23.3 13.3 30 6 30 305 -14.4 0 -14.3 -14.6 12/14/2005 22:50:00 18.5 2 24.4 13.7 18.1 1.9 24.4 13.3 31 5 28 305 -14.5 0 -14.3 -14.6 12/14/2005 23:00:00 18.9 2.2 24.4 13.3 18.4 2.2 23.7 13.3 30 5 27 305 -14.4 0.1 -14.1 -14.6 12/14/2005 23:10:00 19.6 2.2 25.2 14.1 19 2.2 24 13.3 32 6 29 305 -14.4 0.1 -13.9 -14.6 12/14/2005 23:20:00 18.8 1.8 23.3 14.5 18.1 1.7 22.6 13.7 32 6 33 305 -14.3 0.1 -13.9 -14.4 12/14/2005 23:30:00 18.1 2 23.3 13 17.6 1.9 22.6 13.3 32 6 39 305 -14.3 0.1 -13.9 -14.6 12/14/2005 23:40:00 17.9 2.5 24 11.8 17.4 2.3 23.7 11.5 35 6 40 305 -14.4 0.1 -14.1 -14.6 12/14/2005 23:50:00 16.6 2.4 21.8 11.1 16.2 2.3 21.8 11.5 34 6 29 305 -14.4 0.1 -14.1 -14.6 12/15/2005 00:00:00 18.2 1.9 23.7 14.1 17.8 1.9 23.3 13.7 34 5 33 305 -14.5 0.1 -14.1 -14.6 12/15/2005 00:10:00 17.8 2.2 22.9 12.6 17.4 2.1 22.6 13 34 6 34 305 -14.4 0.1 -14.3 -14.6 12/15/2005 00:20:00 18.3 1.8 24 13.7 18 1.8 23.7 13.7 33 6 34 305 -14.4 0.1 -14.1 -14.6 12/15/2005 00:30:00 17.1 2.1 22.9 12.6 16.7 2 22.1 11.8 32 6 37 305 -14.5 0.1 -14.1 -14.6 12/15/2005 00:40:00 18.3 2.5 24.8 12.6 17.9 2.3 24 12.6 32 6 35 305 -14.5 0.1 -14.3 -14.6 12/15/2005 00:50:00 19 2.1 23.7 12.6 18.7 2.1 23.7 12.6 31 6 38 305 -14.4 0.1 -14.1 -14.6 12/15/2005 01:00:00 18.5 1.9 23.3 14.5 18.1 1.8 22.9 13.7 33 6 33 305 -14.4 0.1 -14.1 -14.6 12/15/2005 01:10:00 18.3 2.6 25.2 13.3 17.9 2.6 24.4 13 34 7 28 305 -14.3 0.1 -13.9 -14.6 12/15/2005 01:20:00 19 2 24.4 13.3 18.5 2 23.3 12.6 33 6 27 305 -14.3 0 -13.9 -14.4 12/15/2005 01:30:00 18.6 2.1 23.3 13.3 18.1 2.1 22.6 13 32 6 31 305 -14.3 0 -13.9 -14.4 12/15/2005 01:40:00 17.9 1.9 23.7 13.3 17.5 2.1 22.9 13 33 6 35 305 -14.3 0 -14.3 -14.4 12/15/2005 01:50:00 18.6 2.3 24.4 13.3 18 2.3 24.4 12.6 34 6 30 305 -14.3 0 -13.9 -14.4 12/15/2005 02:00:00 18.3 2.2 25.2 13.3 17.9 2.2 24 12.6 34 6 23 305 -14.3 0 -13.9 -14.4 12/15/2005 02:10:00 18.2 2.3 23.7 12.6 17.8 2.3 23.3 12.2 34 6 27 305 -14.4 0 -13.9 -14.4 12/15/2005 02:20:00 18.4 2.4 23.3 12.2 18 2.4 23.3 12.6 34 6 29 305 -14.4 0 -14.3 -14.4 12/15/2005 02:30:00 18.5 2.5 24 11.8 18 2.5 23.3 12.6 34 6 33 305 -14.4 0 -14.1 -14.6 12/15/2005 02:40:00 19.2 2 24.4 14.1 18.7 2 24.8 13.7 33 7 32 305 -14.5 0 -14.1 -14.6 12/15/2005 02:50:00 18.8 2.3 23.7 13.3 18.3 2.4 23.7 13.3 33 6 28 305 -14.5 0 -14.3 -14.6 12/15/2005 03:00:00 18.1 2.4 24.4 13 17.6 2.3 24.8 12.6 34 6 32 305 -14.4 0 -13.9 -14.6 12/15/2005 03:10:00 18.4 2.5 24 12.6 18 2.4 23.7 13 34 6 32 305 -14.4 0 -13.9 -14.4 12/15/2005 03:20:00 18.6 2.3 23.7 13 18.1 2.3 23.3 12.6 33 7 45 305 -14.4 0 -13.9 -14.6 12/15/2005 03:30:00 17.8 2.2 24 13.7 17.2 2 23.3 12.6 31 6 30 305 -14.3 0 -13.9 -14.4 12/15/2005 03:40:00 18.1 2.6 24 12.6 17.6 2.6 24 12.6 32 7 31 305 -14.3 0 -13.9 -14.4 12/15/2005 03:50:00 20.6 2.3 26.8 16.1 20 2.3 26.3 14.9 31 6 33 305 -14.3 0.1 -13.9 -14.4 12/15/2005 04:00:00 20.2 2.1 25.6 15.3 19.7 2.1 25.2 14.5 34 6 33 305 -14.4 0.1 -13.9 -14.6 12/15/2005 04:10:00 19.4 2.2 26 13.7 19 2.2 24.8 13.7 32 7 31 305 -14.4 0.1 -14.1 -14.6 12/15/2005 04:20:00 19.4 1.8 23.7 14.5 18.9 1.9 24 14.1 29 6 30 305 -14.5 0.2 -14.1 -14.6 12/15/2005 04:30:00 19.1 1.9 24 14.1 18.5 2 23.7 14.1 28 6 21 305 -14.6 0.1 -14.3 -14.6 12/15/2005 04:40:00 17.2 2.5 24.4 11.8 16.7 2.3 22.9 10.7 30 7 27 305 -14.6 0.1 -14.3 -14.6 12/15/2005 04:50:00 18.2 3.2 24.8 11.1 17.8 3.1 24.4 10.3 31 6 33 305 -14.7 0 -14.3 -14.8 12/15/2005 05:00:00 18.3 2.3 23.7 13.3 18 2.1 23.3 12.2 34 6 30 305 -14.7 0 -14.3 -14.8 12/15/2005 05:10:00 17.6 2.1 22.6 13 17.3 2 22.1 13 34 7 36 305 -14.7 0 -14.3 -14.8 12/15/2005 05:20:00 18 2.3 24 12.2 17.6 2.1 23.3 13 32 6 26 305 -14.6 0.1 -14.3 -14.8 12/15/2005 05:30:00 17.9 2.3 23.3 12.2 17.3 2.4 23.3 11.5 31 5 35 305 -14.5 0.1 -14.1 -14.6 12/15/2005 05:40:00 16.7 2.2 22.1 11.8 16.3 2.1 22.1 11.8 31 6 34 305 -14.4 0.1 -13.9 -14.6 12/15/2005 05:50:00 18 2.5 23.7 12.2 17.7 2.3 22.6 12.6 30 6 36 305 -14.2 0.1 -13.7 -14.4 12/15/2005 06:00:00 16.2 1.9 21 11.8 15.6 1.8 20.6 11.1 29 6 19 305 -14.2 0.1 -13.7 -14.3 12/15/2005 06:10:00 15.7 2 20.2 9.9 15.3 1.9 19.5 10.7 29 7 37 305 -14.1 0 -13.7 -14.3 12/15/2005 06:20:00 14.4 1.7 18.3 10.3 13.9 1.7 17.9 9.9 28 6 32 305 -14.2 0 -13.7 -14.3 12/15/2005 06:30:00 15.7 1.5 21.8 12.6 15.4 1.5 20.6 11.8 28 6 33 305 -14.1 0.1 -13.5 -14.3 12/15/2005 06:40:00 16.7 2.3 22.6 10.3 16.2 2.1 21.8 11.1 27 6 28 305 -14 0.1 -13.5 -14.3 12/15/2005 06:50:00 17 2.1 21.8 12.2 16.5 2 22.1 11.8 25 6 25 305 -14 0 -13.5 -14.3 12/15/2005 07:00:00 17 2.3 22.9 12.2 16.6 2.1 22.6 11.8 25 6 20 305 -13.9 0.1 -13.3 -14.1 12/15/2005 07:10:00 17.4 1.8 22.1 13 17 1.8 23.3 11.5 25 6 30 305 -14 0.1 -13.5 -14.1 12/15/2005 07:20:00 17.5 2 22.6 12.2 17.1 2 22.1 11.8 23 6 18 305 -14.1 0.1 -13.5 -14.3 12/15/2005 07:30:00 19.8 2.5 24.4 13 19.3 2.5 24.8 13.7 24 6 21 305 -14.1 0.1 -13.7 -14.3 12/15/2005 07:40:00 19.3 2 24.8 14.5 18.9 1.9 24.4 13.7 22 7 20 305 -14.1 0.1 -13.7 -14.3 12/15/2005 07:50:00 19.9 2.8 27.1 13.3 19.5 2.7 25.6 13 19 6 18 305 -14.1 0.1 -13.7 -14.3 12/15/2005 08:00:00 19.7 2.2 25.6 14.1 19.2 2.1 24.8 14.1 18 6 21 305 -14.1 0.1 -13.7 -14.3 12/15/2005 08:10:00 19 2.5 26 13.3 18.7 2.3 24.8 14.1 20 6 21 305 -14 0.1 -13.5 -14.3 12/15/2005 08:20:00 18.6 2.4 24.8 12.6 18.2 2.5 24.4 11.1 22 7 27 305 -13.9 0.1 -13.5 -14.1 12/15/2005 08:30:00 18.4 2.6 24 11.8 18 2.5 23.3 10.7 20 6 17 305 -13.8 0.1 -13.3 -14.1 12/15/2005 08:40:00 18.7 2.4 25.2 13.7 18.3 2.2 24.8 12.6 22 6 27 305 -13.6 0.1 -13.1 -13.9 12/15/2005 08:50:00 17.4 2.2 22.6 12.6 17.1 2.1 22.6 12.2 24 6 29 305 -13.5 0.2 -13.1 -13.7 12/15/2005 09:00:00 18.9 2.7 26.3 12.6 18.5 2.7 26.3 11.5 26 7 24 305 -13.3 0.1 -12.9 -13.7 12/15/2005 09:10:00 18.4 2.4 25.6 13.3 18 2.3 25.2 13.7 26 7 36 305 -13.3 0.1 -12.9 -13.5 12/15/2005 09:20:00 20.6 2.4 27.9 15.3 20.1 2.4 27.5 14.1 26 7 19 305 -13.2 0.1 -12.7 -13.5 12/15/2005 09:30:00 19.7 2.5 25.2 13 19.3 2.4 24.8 13 27 6 27 305 -13.1 0.1 -12.7 -13.3 12/15/2005 09:40:00 19.8 2.3 24.8 13.7 19.4 2.2 24.4 13.7 28 6 29 305 -13 0.1 -12.5 -13.3 12/15/2005 09:50:00 19.3 2.6 26 12.6 19 2.5 24.4 11.8 28 7 29 305 -12.9 0.1 -12.5 -13.1 12/15/2005 10:00:00 19.3 2.2 24.8 13.7 18.8 2.3 25.6 12.6 27 6 22 305 -12.9 0.1 -12.3 -13.1 12/15/2005 10:10:00 19.5 2.6 26.3 13.3 19.2 2.6 27.1 12.2 26 6 31 305 -12.9 0.1 -12.5 -13.1 12/15/2005 10:20:00 20.9 2.5 27.1 12.2 20.4 2.4 26.8 11.8 25 6 20 305 -13 0.1 -12.5 -13.1 12/15/2005 10:30:00 20.3 2.4 27.5 13.7 19.8 2.4 26.3 13.3 23 6 21 305 -13 0 -12.5 -13.3 12/15/2005 10:40:00 19.3 2.9 26.3 13 18.9 2.8 26.3 13 24 6 20 305 -13 0 -12.5 -13.3 12/15/2005 10:50:00 21.1 2.6 27.1 15.3 20.5 2.6 27.1 15.3 24 6 25 305 -13 0.1 -12.5 -13.1 12/15/2005 11:00:00 19.3 2.3 25.2 13.7 18.8 2.3 24 13 26 6 16 305 -13 0.1 -12.5 -13.1 12/15/2005 11:10:00 19.3 2.6 24.8 13 18.6 2.6 25.6 13.7 26 7 35 305 -12.9 0.2 -12.5 -13.1 12/15/2005 11:20:00 20.5 2.3 25.6 15.6 19.9 2.2 26 15.3 28 6 27 305 -13 0.1 -12.5 -13.3 12/15/2005 11:30:00 21.5 2.8 28.7 14.9 20.7 2.7 27.9 14.5 26 7 23 305 -13 0.1 -12.5 -13.3 12/15/2005 11:40:00 23.7 2.4 29.1 17.6 23 2.4 27.9 17.2 24 6 25 305 -13.1 0.1 -12.5 -13.3 12/15/2005 11:50:00 22.4 2.7 29.8 16.1 21.9 2.6 30.2 16.1 27 6 25 305 -13.2 0.1 -12.7 -13.5 12/15/2005 12:00:00 22.3 2.5 29.1 16.4 21.6 2.5 29.1 16.1 29 7 23 305 -13.3 0.1 -12.7 -13.5 12/15/2005 12:10:00 20.1 2.4 25.2 15.3 19.7 2.3 25.2 14.1 31 7 23 305 -13.4 0 -12.9 -13.5 12/15/2005 12:20:00 18.9 2.6 24.4 12.6 18.5 2.6 24.8 13 27 7 27 305 -13.4 0.1 -12.9 -13.5 12/15/2005 12:30:00 19.6 2.9 26.3 13.3 19.1 2.8 26 13 26 7 24 305 -13.4 0.1 -12.9 -13.5 12/15/2005 12:40:00 19.9 2.6 26 13 19.4 2.5 25.6 13 25 7 27 305 -13.3 0.1 -12.9 -13.5 12/15/2005 12:50:00 19.2 2.4 26.8 13.3 18.8 2.3 26 13 27 7 28 305 -13.1 0.1 -12.7 -13.3 12/15/2005 13:00:00 20.3 2.4 26 13 19.8 2.4 25.6 13.3 26 6 24 305 -13.1 0.1 -12.7 -13.3 12/15/2005 13:10:00 21.4 2.4 26.8 14.9 20.6 2.4 26 14.9 24 6 27 305 -13 0.1 -12.5 -13.3 12/15/2005 13:20:00 20.4 2.4 26.8 14.9 19.8 2.4 25.2 13.3 25 6 26 305 -13.1 0 -12.5 -13.3 12/15/2005 13:30:00 22.1 2.7 27.5 14.9 21.5 2.6 26.8 14.5 23 6 17 305 -13 0.1 -12.5 -13.1 12/15/2005 13:40:00 21.4 2.9 29.1 14.5 20.8 2.8 29.1 14.5 23 6 11 305 -12.9 0.1 -12.5 -13.1 12/15/2005 13:50:00 22.9 2.7 30.6 17.2 22.3 2.7 29.1 16.8 24 6 24 305 -13 0.1 -12.5 -13.1 12/15/2005 14:00:00 21 2.7 27.5 15.3 20.3 2.6 26.3 15.3 24 6 30 305 -13 0.1 -12.5 -13.1 12/15/2005 14:10:00 20 3.1 27.5 11.8 19.6 3.1 28.3 11.5 24 7 35 305 -13.1 0 -12.5 -13.3 12/15/2005 14:20:00 20.3 2.5 27.5 14.5 19.5 2.7 25.6 13.7 25 7 17 305 -13.1 0 -12.5 -13.3 12/15/2005 14:30:00 21.9 2.5 28.3 16.1 21.3 2.4 27.1 14.9 26 6 27 305 -13.1 0 -12.7 -13.3 12/15/2005 14:40:00 22.5 2.2 29.4 14.1 21.9 2.3 29.8 15.6 24 6 29 305 -13.1 0 -12.7 -13.3 12/15/2005 14:50:00 19.9 2.7 27.1 14.9 19.6 2.6 26.8 14.5 25 7 17 305 -13.1 0 -12.7 -13.3 12/15/2005 15:00:00 21 2.7 27.1 13.7 20.5 2.5 27.1 14.1 25 7 24 305 -13.2 0.1 -12.7 -13.3 12/15/2005 15:10:00 21.5 2.9 28.3 14.9 20.9 2.7 27.1 15.3 26 7 30 305 -13.2 0.1 -12.7 -13.3 12/15/2005 15:20:00 21.5 2.7 29.1 14.9 21 2.7 29.8 15.3 27 7 28 305 -13.2 0.1 -12.7 -13.5 12/15/2005 15:30:00 21.2 2.6 27.5 14.9 20.6 2.6 26.8 14.1 27 6 23 305 -13.2 0.1 -12.7 -13.3 12/15/2005 15:40:00 18.9 2.6 27.9 13 18.5 2.6 26.8 12.6 27 7 21 305 -13 0.1 -12.5 -13.3 12/15/2005 15:50:00 20.8 2.8 29.1 14.1 20.3 2.8 27.9 14.5 24 6 18 305 -12.9 0.1 -12.5 -13.1 12/15/2005 16:00:00 22.5 2.3 27.9 17.2 21.9 2.2 26.8 16.1 24 6 21 305 -12.9 0.1 -12.5 -13.1 12/15/2005 16:10:00 20.7 2.6 28.3 15.3 20.1 2.6 26.8 14.5 26 6 28 305 -12.9 0.2 -12.5 -13.1 12/15/2005 16:20:00 20.5 2.7 27.5 13.7 19.9 2.6 26.3 13.3 26 6 19 305 -12.9 0.1 -12.5 -13.1 12/15/2005 16:30:00 22.3 2.5 29.1 15.3 21.5 2.4 27.5 14.9 25 6 31 305 -12.9 0.1 -12.5 -13.1 12/15/2005 16:40:00 21.8 2.4 27.1 16.1 21.4 2.2 27.1 16.1 24 7 31 305 -12.9 0.1 -12.5 -13.1 12/15/2005 16:50:00 22 2.9 29.1 14.9 21.5 2.8 28.3 14.1 22 6 31 305 -12.9 0.1 -12.5 -13.1 12/15/2005 17:00:00 23.5 2.6 28.7 16.4 22.9 2.4 28.3 16.1 22 6 25 305 -12.9 0.1 -12.5 -13.1 12/15/2005 17:10:00 23.1 2.3 29.4 16.1 22.4 2.4 30.6 16.4 21 6 17 305 -12.9 0.1 -12.5 -13.1 12/15/2005 17:20:00 22.6 2.6 29.4 15.6 22 2.6 29.1 15.6 22 6 24 305 -12.9 0.1 -12.5 -13.1 12/15/2005 17:30:00 21.9 3.1 28.3 14.1 21.2 3.1 27.5 13.3 24 6 30 305 -12.9 0.1 -12.5 -13.1 12/15/2005 17:40:00 23.1 2.6 28.7 16.4 22.4 2.7 27.9 15.3 25 6 22 305 -12.9 0.1 -12.5 -13.1 12/15/2005 17:50:00 21.2 2.2 26.8 15.3 20.7 2 26.3 15.6 26 6 31 305 -12.9 0.1 -12.5 -13.1 12/15/2005 18:00:00 21.1 3.2 27.1 13.3 20.6 3.2 27.5 13 25 6 21 305 -12.9 0.1 -12.5 -12.9 12/15/2005 18:10:00 22.9 2.3 28.3 16.8 22.4 2.2 27.5 16.1 22 6 23 305 -12.8 0 -12.3 -12.9 12/15/2005 18:20:00 20.9 2.4 27.1 15.6 20.4 2.3 25.6 15.3 23 6 21 305 -12.7 0 -12.3 -12.9 12/15/2005 18:30:00 19.8 2.9 27.5 13.3 19.2 2.8 26.3 13.7 23 6 23 305 -12.6 0 -12.1 -12.9 12/15/2005 18:40:00 21.1 2.5 26.8 15.6 20.5 2.5 26.8 14.9 25 6 21 305 -12.7 0 -12.3 -12.9 12/15/2005 18:50:00 19.3 2.6 26.3 14.1 19 2.6 25.6 13.7 24 6 24 305 -12.7 0.1 -12.1 -12.9 12/15/2005 19:00:00 19.7 2.2 25.6 14.5 19.1 2.1 24.8 14.5 27 6 23 305 -12.7 0.1 -12.3 -12.9 12/15/2005 19:10:00 20.9 2.4 27.1 14.5 20.3 2.3 27.5 14.1 27 7 19 305 -12.9 0.1 -12.5 -13.1 12/15/2005 19:20:00 22.2 2.7 28.7 14.9 21.6 2.6 28.3 15.6 26 6 24 305 -12.8 0 -12.3 -13.1 12/15/2005 19:30:00 22.7 2.5 28.7 16.1 22.1 2.4 27.9 16.8 24 7 23 305 -12.8 0.1 -12.3 -12.9 12/15/2005 19:40:00 22.1 3.2 30.2 14.9 21.6 3.1 29.4 14.5 27 7 39 305 -12.8 0.2 -12.3 -13.1 12/15/2005 19:50:00 21.4 2.8 28.3 13.7 20.9 2.8 27.9 13.3 29 6 25 305 -12.9 0.1 -12.5 -13.1 12/15/2005 20:00:00 20.1 3.3 28.3 12.6 19.6 3.2 27.5 11.8 26 6 27 305 -12.9 0.1 -12.5 -13.1 12/15/2005 20:10:00 20.5 2.9 26.3 13.7 19.8 2.9 27.1 12.6 22 7 16 305 -12.9 0.1 -12.5 -13.1 12/15/2005 20:20:00 21 2.9 27.5 14.5 20.4 2.8 27.5 13.7 25 7 23 305 -13 0.1 -12.5 -13.1 12/15/2005 20:30:00 21.1 3.2 29.8 13.7 20.6 3.2 27.9 13.7 29 6 27 305 -13.1 0 -12.5 -13.3 12/15/2005 20:40:00 23.7 2.6 29.8 17.6 23.2 2.5 29.8 17.2 26 7 23 305 -13.2 0 -12.7 -13.3 12/15/2005 20:50:00 22 2.4 29.1 16.4 21.3 2.3 28.7 15.3 26 6 39 305 -13.2 0 -12.7 -13.3 12/15/2005 21:00:00 21.4 2.8 29.4 14.1 20.9 2.7 28.7 15.3 25 6 26 305 -13.3 0.1 -12.9 -13.5 12/15/2005 21:10:00 21.6 2.8 28.7 13.7 20.9 2.7 26.8 13.7 25 7 22 305 -13.3 0 -12.9 -13.5 12/15/2005 21:20:00 22.9 2.7 29.4 16.4 22.4 2.7 29.4 15.3 26 6 22 305 -13.4 0 -12.9 -13.5 12/15/2005 21:30:00 21.8 2.8 29.1 14.9 21.2 2.7 29.1 15.3 23 7 33 305 -13.4 0.1 -12.9 -13.5 12/15/2005 21:40:00 23.9 2.7 29.8 16.8 23.4 2.6 29.1 16.8 23 6 21 305 -13.5 0.1 -12.9 -13.7 12/15/2005 21:50:00 23.8 2.6 30.2 17.2 23.2 2.6 29.1 17.6 24 6 18 305 -13.5 0.1 -13.1 -13.7 12/15/2005 22:00:00 22.6 2.9 30.2 15.3 22 2.8 29.1 15.6 24 6 35 305 -13.5 0.1 -13.1 -13.7 12/15/2005 22:10:00 24.2 2.8 30.9 17.2 23.7 2.7 30.2 17.2 25 6 16 305 -13.6 0 -13.3 -13.9 12/15/2005 22:20:00 24.4 2.8 30.2 16.4 23.8 2.8 30.2 16.8 24 6 19 305 -13.8 0.1 -13.3 -14.1 12/15/2005 22:30:00 24.3 2.8 30.9 16.8 23.8 2.7 32.1 16.1 22 6 18 305 -13.9 0.1 -13.5 -14.3 12/15/2005 22:40:00 25.2 2.7 30.9 17.6 24.5 2.6 30.2 16.1 25 7 24 305 -13.9 0.1 -13.5 -14.3 12/15/2005 22:50:00 22 2.7 28.7 14.1 21.6 2.7 29.1 14.1 23 6 14 305 -13.9 0.1 -13.5 -14.3 12/15/2005 23:00:00 22.3 2.7 29.1 16.4 21.8 2.7 28.7 14.9 25 6 20 305 -14 0.1 -13.7 -14.3 12/15/2005 23:10:00 22.9 2.6 29.1 16.4 22.4 2.6 29.1 15.3 26 7 18 305 -14.1 0.1 -13.7 -14.4 12/15/2005 23:20:00 23.3 3.1 29.8 16.8 22.6 2.9 28.3 15.6 27 6 30 305 -14.1 0.1 -13.7 -14.3 12/15/2005 23:30:00 23 2.6 29.4 16.1 22.4 2.5 29.1 15.6 28 7 25 305 -14.1 0.1 -13.7 -14.3 12/15/2005 23:40:00 20.3 2.6 27.9 14.5 19.8 2.6 27.1 13.3 29 8 30 305 -14.2 0 -13.7 -14.3 12/15/2005 23:50:00 22.3 2.7 28.7 16.1 21.7 2.9 29.1 14.5 28 7 30 305 -14.2 0.1 -13.7 -14.4 12/16/2005 00:00:00 22.1 2.5 27.5 14.9 21.7 2.4 27.1 16.1 31 6 32 305 -14.2 0 -13.7 -14.4 12/16/2005 00:10:00 21.1 2.7 27.9 14.1 20.6 2.6 27.5 14.5 28 7 21 305 -14.4 0 -14.3 -14.4 12/16/2005 00:20:00 22.5 2.6 28.7 14.5 21.8 2.4 27.1 14.5 25 7 27 305 -14.4 0 -14.1 -14.6 12/16/2005 00:30:00 22.9 3.1 29.4 14.1 22.4 2.9 29.4 13.7 24 6 26 305 -14.4 0 -14.3 -14.6 12/16/2005 00:40:00 24.2 3.1 32.1 16.8 23.5 3.2 30.9 16.4 26 6 25 305 -14.6 0.1 -13.9 -14.6 12/16/2005 00:50:00 23.4 3.2 30.6 14.9 23 3.1 30.2 14.1 26 6 23 305 -14.6 0 -14.3 -14.6 12/16/2005 01:00:00 24.4 3.2 31.8 16.8 23.9 3.1 30.6 16.8 24 6 22 305 -14.6 0 -14.3 -14.6 12/16/2005 01:10:00 25.2 2.7 31.3 16.8 24.4 2.7 30.9 17.2 23 6 16 305 -14.5 0 -14.3 -14.6 12/16/2005 01:20:00 22.2 3.6 30.9 14.9 21.6 3.5 30.6 15.6 24 7 25 305 -14.4 0 -14.3 -14.6 12/16/2005 01:30:00 22.5 2.3 30.6 16.8 22 2.3 29.1 16.1 24 6 26 305 -14.5 0 -14.3 -14.6 12/16/2005 01:40:00 23.7 2.4 29.1 17.6 23.4 2.4 29.4 18.3 23 6 17 305 -14.7 0 -14.3 -14.6 12/16/2005 01:50:00 24.4 3.1 31.3 16.4 23.7 2.9 31.3 15.3 23 6 19 305 -14.7 0 -14.3 -14.8 12/16/2005 02:00:00 23.3 2.5 30.2 17.2 22.7 2.5 29.1 16.4 23 6 23 305 -14.6 0 -14.3 -14.6 12/16/2005 02:10:00 23.5 2.7 29.8 16.8 22.8 2.6 28.7 16.4 24 7 29 305 -14.7 0 -14.4 -14.6 12/16/2005 02:20:00 22.6 2.8 31.8 14.5 22 2.7 30.6 14.5 25 6 22 305 -14.5 0.1 -14.3 -14.6 12/16/2005 02:30:00 24.9 2.8 30.9 18.3 24.5 2.8 30.2 17.6 24 6 22 305 -14.5 0.1 -14.3 -14.6 12/16/2005 02:40:00 26.1 2.9 34 19.1 25.5 2.9 34 18.7 23 6 25 305 -14.4 0.1 -14.1 -14.6 12/16/2005 02:50:00 25.6 2.5 32.9 19.9 24.9 2.6 31.3 18.7 24 6 18 305 -14.6 0.1 -14.3 -14.8 12/16/2005 03:00:00 24 2.9 30.2 16.8 23.5 2.9 30.6 16.1 25 6 28 305 -14.7 0 -14.3 -14.8 12/16/2005 03:10:00 24.4 3.2 31.3 16.8 23.8 3.2 31.3 16.8 23 6 30 305 -14.7 0 -14.3 -15 12/16/2005 03:20:00 23.3 2.7 30.2 16.4 22.9 2.6 30.2 16.8 23 6 19 305 -14.7 0 -14.4 -15 12/16/2005 03:30:00 22.2 2.8 27.9 16.1 21.8 2.8 28.3 15.6 22 6 22 305 -14.8 0 -14.4 -15 12/16/2005 03:40:00 21.8 2.9 29.4 14.1 21.5 2.9 29.8 14.1 24 5 24 305 -14.8 0 -14.4 -15 12/16/2005 03:50:00 21.6 2.5 27.5 14.5 21.2 2.5 28.3 14.5 22 6 21 305 -14.9 0.1 -14.6 -15 12/16/2005 04:00:00 22.3 2.9 28.7 15.3 21.8 2.9 28.7 15.3 22 6 23 305 -15 0.1 -14.6 -15.2 12/16/2005 04:10:00 21.6 2.6 27.9 14.9 21.2 2.6 26.8 14.9 20 6 9 305 -15.1 0.1 -14.6 -15.2 12/16/2005 04:20:00 22.7 2.9 28.7 14.5 22.3 2.8 27.9 14.9 19 6 20 305 -15.2 0.1 -14.8 -15.6 12/16/2005 04:30:00 22.7 2.8 29.4 14.9 22.2 2.8 29.1 14.5 18 6 14 305 -15.2 0 -14.8 -15.4 12/16/2005 04:40:00 22.6 2.6 28.3 16.4 22 2.6 27.5 15.6 20 6 28 305 -15.3 0 -15 -15.6 12/16/2005 04:50:00 23.3 2.7 30.6 15.3 22.8 2.6 30.2 15.3 20 6 16 305 -15.5 0 -15 -15.6 12/16/2005 05:00:00 22.8 2.7 28.3 15.6 22.3 2.5 27.9 14.5 21 6 33 305 -15.5 0 -15 -15.6 12/16/2005 05:10:00 22.5 2.7 27.9 17.2 21.8 2.5 27.1 16.4 20 7 22 305 -15.5 0 -15 -15.6 12/16/2005 05:20:00 21.5 2.5 27.5 16.1 21 2.6 27.1 15.6 19 7 14 305 -15.4 0 -15 -15.6 12/16/2005 05:30:00 21.7 3.5 29.1 13.7 21.1 3.5 29.4 13 20 7 23 305 -15.5 0 -15 -15.6 12/16/2005 05:40:00 20.3 2.7 26.8 14.5 19.8 2.7 26.8 14.5 20 6 19 305 -15.4 0 -15 -15.6 12/16/2005 05:50:00 22.1 2.9 30.2 15.3 21.6 2.8 29.8 14.9 19 7 16 305 -15.4 0 -15 -15.6 12/16/2005 06:00:00 20.9 2.6 27.5 15.6 20.5 2.6 27.9 14.9 20 6 19 305 -15.5 0 -15 -15.6 12/16/2005 06:10:00 21.1 2.4 27.1 14.9 20.7 2.4 27.5 15.6 21 6 13 305 -15.5 0 -15 -15.8 12/16/2005 06:20:00 17.9 2.4 24 12.2 17.5 2.5 24 11.5 18 7 22 305 -15.6 0 -15 -15.8 12/16/2005 06:30:00 20.1 3.2 28.7 14.1 19.7 3.1 28.3 13.7 20 7 14 305 -15.7 0.1 -15.2 -15.8 12/16/2005 06:40:00 22.2 3.1 29.4 14.1 21.7 3.1 28.3 14.9 21 6 27 305 -15.8 0 -15.4 -16 12/16/2005 06:50:00 21.6 2.6 29.1 15.3 21 2.4 28.7 15.6 21 6 23 305 -15.9 0 -15.6 -16 12/16/2005 07:00:00 22.6 2.1 28.7 17.9 22.1 2.3 27.5 17.2 20 6 32 305 -15.9 0 -15.8 -16 12/16/2005 07:10:00 23 2.8 29.1 15.3 22.6 2.8 29.1 15.6 18 6 19 305 -16 0 -15.8 -16.2 12/16/2005 07:20:00 22.1 2.3 27.1 16.4 21.6 2.4 27.5 15.6 18 6 19 305 -16.2 0 -15.8 -16.4 12/16/2005 07:30:00 21.3 2.8 27.1 13.7 20.9 2.8 27.1 13 19 6 25 305 -16.2 0.1 -16 -16.4 12/16/2005 07:40:00 21.3 2.5 27.5 15.3 21 2.5 27.5 14.9 19 5 15 305 -16.3 0 -16 -16.4 12/16/2005 07:50:00 19.6 2.2 25.6 14.9 19.3 2.1 26 14.1 20 6 11 305 -16.2 0 -16 -16.4 12/16/2005 08:00:00 20 2.5 25.6 14.5 19.6 2.5 26.3 14.5 19 6 24 305 -16.3 0 -16 -16.4 12/16/2005 08:10:00 20.7 2.6 27.1 15.3 20.1 2.6 27.1 15.3 19 6 7 305 -16.2 0.1 -15.8 -16.4 12/16/2005 08:20:00 20.5 2.7 27.9 14.1 20.1 2.7 29.1 14.5 19 6 19 305 -16.1 0.1 -15.8 -16.4 12/16/2005 08:30:00 22.5 3.1 28.7 14.1 22.2 2.9 29.1 15.6 19 6 23 305 -16.1 0.1 -15.8 -16.4 12/16/2005 08:40:00 22.1 2.3 27.1 15.6 21.6 2.3 27.5 15.6 17 7 19 305 -16.1 0.1 -15.8 -16.4 12/16/2005 08:50:00 22.1 2.8 28.3 13.7 21.5 2.8 27.9 14.1 16 6 19 305 -16.2 0.1 -16 -16.4 12/16/2005 09:00:00 21.2 2.9 27.5 13.3 20.8 2.7 26.3 13.7 17 6 15 305 -16.1 0 -15.8 -16.4 12/16/2005 09:10:00 22 2.2 27.1 16.1 21.5 2.3 28.3 16.4 20 6 14 305 -16.2 0.1 -15.8 -16.4 12/16/2005 09:20:00 22.3 2.5 28.3 16.4 21.7 2.5 27.5 16.1 21 7 27 305 -16.2 0.1 -16 -16.4 12/16/2005 09:30:00 22.2 2.4 29.1 16.4 21.8 2.5 27.9 15.3 21 7 20 305 -16.3 0 -16 -16.4 12/16/2005 09:40:00 22.1 2.5 28.3 16.4 21.6 2.6 28.3 14.9 20 6 17 305 -16.4 0 -16 -16.6 12/16/2005 09:50:00 20.7 2.6 26.8 14.5 20.3 2.6 27.1 14.5 19 7 17 305 -16.3 0 -16 -16.6 12/16/2005 10:00:00 22 2.8 29.1 14.1 21.6 2.6 27.5 14.5 17 6 19 305 -16.4 0 -16 -16.6 12/16/2005 10:10:00 21.2 3.1 28.3 14.1 20.9 3.1 28.3 13.7 20 6 21 305 -16.4 0 -16.4 -16.6 12/16/2005 10:20:00 20.5 3.5 28.7 12.2 20.1 3.3 28.3 12.6 17 7 13 305 -16.6 0.1 -16.4 -16.9 12/16/2005 10:30:00 22.3 2.7 29.4 15.3 21.8 2.7 28.3 15.3 19 6 20 305 -16.5 0 -16.2 -16.6 12/16/2005 10:40:00 21.3 2.5 27.1 14.9 21 2.4 26.8 14.9 20 6 16 305 -16.5 0 -16.4 -16.7 12/16/2005 10:50:00 17.9 2.8 27.5 11.1 17.6 2.8 27.1 11.8 15 6 12 305 -17 0.3 -16.6 -17.5 12/16/2005 11:00:00 17 1.6 21 13 16.8 1.6 20.6 12.6 6 5 5 305 -17.9 0.3 -17.3 -18.4 12/16/2005 11:10:00 15.9 1.7 21 10.3 15.7 1.7 21 11.1 9 5 0 305 -18 0.1 -17.7 -18.2 12/16/2005 11:20:00 17.1 2 21.8 12.6 16.8 1.9 21.4 12.6 8 6 2 305 -18.3 0.1 -18.1 -18.4 12/16/2005 11:30:00 16.1 1.7 19.9 12.2 15.9 1.8 19.9 12.2 9 6 11 305 -18.3 0.2 -18.1 -18.4 12/16/2005 11:40:00 16.2 1.7 20.6 11.5 16.2 1.7 20.2 12.2 7 6 7 305 -18.2 0.1 -18.1 -18.4 12/16/2005 11:50:00 17.1 1.6 21.4 13 17 1.6 21.4 13 3 6 7 305 -18.7 0.2 -18.1 -19 12/16/2005 12:00:00 16.7 2 21.4 12.6 16.5 1.9 20.6 12.6 5 6 6 305 -19.2 0.1 -19 -19.5 12/16/2005 12:10:00 17 2 21.8 12.2 16.9 2 22.1 12.6 8 5 11 305 -18.9 0.1 -18.6 -19.3 12/16/2005 12:20:00 16.1 1.8 20.6 11.8 15.9 1.9 20.2 11.1 7 6 356 305 -18.7 0 -18.4 -18.8 12/16/2005 12:30:00 16.5 1.7 21.4 12.2 16.3 1.6 21 12.2 8 5 3 305 -18.6 0 -18.4 -18.8 12/16/2005 12:40:00 16.9 1.9 21.8 11.5 16.8 2.1 22.9 11.5 7 6 14 305 -18.8 0.1 -18.4 -19 12/16/2005 12:50:00 16.6 2.3 21.4 11.1 16.3 2.4 21.8 10.3 10 6 16 305 -19.1 0 -19 -19.2 12/16/2005 13:00:00 17.5 1.8 22.1 12.6 17.1 1.9 21.8 12.2 10 5 12 305 -19.2 0 -19 -19.5 12/16/2005 13:10:00 15.3 1.7 19.9 11.1 15 1.7 18.7 10.3 12 6 9 305 -18.8 0.2 -18.2 -19 12/16/2005 13:20:00 18.1 2.3 24.8 12.6 17.8 2.2 24 13 22 6 22 305 -18.1 0 -18.1 -18.4 12/16/2005 13:30:00 17.1 2.7 24 11.1 16.9 2.6 24 10.7 14 7 18 305 -18.5 0.4 -18.1 -19 12/16/2005 13:40:00 16.4 2.2 22.9 11.5 16.1 2.2 21.8 11.1 13 7 25 305 -18.9 0.1 -18.4 -19 12/16/2005 13:50:00 15.6 1.7 20.2 11.8 15.4 1.8 19.9 10.7 13 6 21 305 -18.9 0.2 -18.4 -19.2 12/16/2005 14:00:00 18 2.2 22.9 12.6 17.6 2.2 22.9 12.6 20 6 20 305 -18.6 0 -18.2 -18.8 12/16/2005 14:10:00 18.4 2.1 24 13.7 17.9 2.1 22.9 13 21 7 27 305 -18.6 0 -18.4 -18.6 12/16/2005 14:20:00 20.1 2.3 24.8 13.3 19.5 2.2 24.4 13 22 6 19 305 -18.5 0 -18.2 -18.4 12/16/2005 14:30:00 19.1 2.3 24.4 14.1 18.8 2.3 24.8 14.1 22 6 18 305 -18.5 0 -18.2 -18.6 12/16/2005 14:40:00 19.5 2.4 25.2 14.1 19 2.4 24.4 13 22 6 23 305 -18.5 0 -18.2 -18.8 12/16/2005 14:50:00 19.7 2.5 25.2 14.1 19.1 2.5 24.4 12.6 20 6 19 305 -18.6 0 -18.4 -18.8 12/16/2005 15:00:00 18.8 2.4 24.8 13 18.4 2.4 23.7 13.3 18 6 22 305 -18.7 0 -18.4 -19 12/16/2005 15:10:00 19.3 2.3 24.8 13.7 18.7 2.2 24 14.1 17 6 22 305 -18.8 0 -18.6 -19 12/16/2005 15:20:00 17.5 2.4 24 11.8 17.1 2.3 23.7 11.5 19 6 21 305 -18.7 0 -18.4 -19 12/16/2005 15:30:00 18.3 2.5 24 12.2 18.1 2.4 23.7 13 20 6 33 305 -18.7 0 -18.4 -18.8 12/16/2005 15:40:00 17.2 2 23.3 13 16.9 1.8 21.8 12.6 18 6 10 305 -18.7 0 -18.4 -19 12/16/2005 15:50:00 18.9 2 23.3 13 18.5 2 22.6 13.3 18 6 13 305 -18.7 0 -18.4 -19 12/16/2005 16:00:00 18.4 2.5 23.3 13 18 2.3 22.6 12.2 19 5 12 305 -18.8 0 -18.6 -19 12/16/2005 16:10:00 19.3 2.2 24.8 14.1 18.8 2.2 24.8 13.7 18 6 19 305 -18.7 0 -18.6 -19 12/16/2005 16:20:00 19.2 2.2 24 13.3 18.8 2.1 23.3 13.7 18 6 23 305 -18.7 0 -18.4 -19 12/16/2005 16:30:00 20.1 2.4 24.8 14.1 19.9 2.4 24.8 14.5 17 5 16 305 -18.7 0 -18.4 -18.8 12/16/2005 16:40:00 18.9 2.3 24.8 13 18.5 2.2 25.2 13.3 19 6 17 305 -18.5 0 -18.2 -18.6 12/16/2005 16:50:00 19.9 2.3 26 14.9 19.8 2.3 25.2 13.3 17 5 16 305 -18.4 0 -18.2 -18.4 12/16/2005 17:00:00 17.9 2.3 23.3 13.3 17.8 2.2 23.3 12.2 16 6 17 305 -18.7 0.2 -18.2 -19 12/16/2005 17:10:00 19.3 2.2 25.2 14.5 19 2 24.4 14.1 16 6 7 305 -18.3 0 -18.1 -18.4 12/16/2005 17:20:00 18.9 2 24.4 13.3 18.5 2 24.4 13.3 16 6 4 305 -18.4 0 -18.2 -18.4 12/16/2005 17:30:00 19.3 2.2 24.8 13.7 19 2.3 24.4 14.1 18 6 22 305 -18.2 0.1 -18.1 -18.4 12/16/2005 17:40:00 19.7 2.1 23.7 13 19.4 2.3 24.8 13 19 6 20 305 -18 0 -17.9 -18.2 12/16/2005 17:50:00 17.4 2.1 22.9 12.2 17.3 2.1 22.6 12.2 6 7 17 305 -19.3 0.8 -17.9 -20.1 12/16/2005 18:00:00 15.8 1.7 21 11.8 15.7 1.7 21 11.8 6 6 3 305 -20.1 0.1 -19.9 -20.2 12/16/2005 18:10:00 16 1.6 19.9 11.5 15.8 1.6 19.5 11.8 6 6 6 305 -19.8 0.1 -19.5 -20.1 12/16/2005 18:20:00 16.6 2 23.3 12.2 16.5 2 21.8 11.8 14 7 20 305 -18.8 0.5 -18.1 -19.5 12/16/2005 18:30:00 18.5 2.4 25.2 13 18.2 2.5 26 13 15 6 9 305 -18 0 -17.7 -18.1 12/16/2005 18:40:00 19.3 2.4 24.8 13.3 18.9 2.4 24.4 13.3 18 6 16 305 -17.9 0 -17.7 -18.1 12/16/2005 18:50:00 19.5 2.5 26 14.1 19.1 2.5 25.2 13 20 6 18 305 -17.8 0 -17.7 -18.1 12/16/2005 19:00:00 19.9 2 25.6 15.6 19.5 1.9 24.8 15.6 21 6 28 305 -17.7 0 -17.5 -17.9 12/16/2005 19:10:00 20.6 2.1 26 15.3 20.1 2.2 25.6 14.5 20 6 14 305 -17.7 0 -17.5 -17.9 12/16/2005 19:20:00 20.3 2.4 27.1 14.9 19.9 2.4 26.8 14.9 21 6 23 305 -17.6 0 -17.5 -17.9 12/16/2005 19:30:00 20.7 2.1 24.8 14.9 20.1 2.1 24.4 14.1 20 5 17 305 -17.5 0 -17.5 -17.7 12/16/2005 19:40:00 19.4 2.3 24 14.1 19.1 2.3 24.4 13.7 21 5 15 305 -17.5 0 -17.3 -17.5 12/16/2005 19:50:00 19.9 2.4 25.2 14.1 19.6 2.2 25.2 14.5 20 6 27 305 -17.3 0.1 -17.1 -17.5 12/16/2005 20:00:00 20 2.3 25.2 13.7 19.7 2.4 25.6 14.1 17 6 17 305 -17.2 0 -16.9 -17.3 12/16/2005 20:10:00 19.3 2.5 25.2 13.7 18.9 2.5 25.6 13 17 6 17 305 -17.2 0 -16.9 -17.3 12/16/2005 20:20:00 15.9 2.6 24 10.3 15.6 2.5 23.7 9.5 9 7 17 305 -17.8 0.4 -16.9 -18.2 12/16/2005 20:30:00 18.7 2.7 25.2 12.2 18.3 2.7 25.2 12.2 20 7 34 305 -17.4 0.3 -16.9 -18.1 12/16/2005 20:40:00 20.7 2.1 25.2 14.5 20.2 2 25.6 14.9 19 6 18 305 -17.1 0 -16.9 -17.3 12/16/2005 20:50:00 19.4 2.2 24.4 13.3 19 2.2 25.2 13.3 19 6 19 305 -17.1 0 -16.9 -17.3 12/16/2005 21:00:00 19.9 2.3 25.6 13.7 19.5 2.3 24.8 13.7 22 6 25 305 -17 0 -16.9 -17.3 12/16/2005 21:10:00 18.3 2.4 24 13 18.1 2.3 23.7 13 20 6 21 305 -17 0 -16.9 -17.1 12/16/2005 21:20:00 16.4 1.7 20.6 12.6 16.2 1.5 19.9 12.2 9 8 3 305 -17.8 0.6 -16.9 -18.4 12/16/2005 21:30:00 15.6 1.7 19.5 11.1 15.3 1.8 19.1 10.3 9 6 11 305 -18.1 0.1 -18.1 -18.4 12/16/2005 21:40:00 15.4 1.7 19.9 11.5 15.3 1.7 19.9 11.8 8 5 9 305 -18.1 0.1 -17.9 -18.2 12/16/2005 21:50:00 17.2 2.3 24 11.8 16.8 2.2 22.9 11.8 20 7 24 305 -17.4 0.2 -16.9 -18.1 12/16/2005 22:00:00 18.9 2.4 24.8 12.6 18.5 2.4 26 13.7 21 6 17 305 -17.1 0 -16.9 -17.3 12/16/2005 22:10:00 19.1 2.7 25.2 13 18.7 2.6 24.8 11.8 20 6 21 305 -17.2 0 -16.9 -17.3 12/16/2005 22:20:00 18.7 2.3 24 13.3 18.2 2.3 23.3 13 22 6 22 305 -17.1 0 -16.9 -17.3 12/16/2005 22:30:00 17.1 2 21.8 12.6 16.8 2 21.8 11.5 18 8 15 305 -17.3 0.3 -16.9 -17.9 12/16/2005 22:40:00 16.2 1.7 20.2 11.8 16 1.7 20.2 12.2 10 6 16 305 -18.3 0.1 -17.7 -18.4 12/16/2005 22:50:00 14.5 1.8 19.1 8.8 14.3 1.8 18.3 9.5 12 6 18 305 -18.1 0 -17.9 -18.4 12/16/2005 23:00:00 16.1 2.3 22.6 10.7 15.9 2.2 22.6 10.7 19 7 21 305 -17.6 0.2 -17.3 -18.1 12/16/2005 23:10:00 17.1 2.3 22.6 12.2 16.7 2.2 22.6 12.2 22 6 22 305 -17.4 0 -17.1 -17.5 12/16/2005 23:20:00 18.4 2.1 23.7 13 18 2.1 23.7 12.6 22 6 23 305 -17.5 0 -17.5 -17.7 12/16/2005 23:30:00 16.5 2.2 21.8 12.2 16.2 2.1 21.4 11.8 25 6 21 305 -17.5 0 -17.3 -17.7 12/16/2005 23:40:00 17.1 2.1 21.8 12.6 16.7 2.1 21 11.5 22 6 19 305 -17.5 0 -17.1 -17.5 12/16/2005 23:50:00 14.5 1.7 19.1 9.9 14.3 1.6 18.3 10.3 9 6 13 305 -18 0.1 -17.5 -18.2 12/17/2005 00:00:00 13.5 1.8 19.1 9.1 13.3 1.8 18.3 9.5 13 6 27 305 -17.9 0.1 -17.5 -18.2 12/17/2005 00:10:00 16.5 2.1 21.4 11.8 16.3 2.1 21.8 11.5 18 6 24 305 -17.5 0 -17.1 -17.5 12/17/2005 00:20:00 15.4 1.8 19.9 11.5 15.1 1.9 20.2 9.9 18 6 10 305 -17.4 0 -17.1 -17.5 12/17/2005 00:30:00 16.9 1.9 20.6 12.2 16.5 1.8 20.6 11.8 23 6 21 305 -17.4 0 -17.1 -17.5 12/17/2005 00:40:00 15.6 2.1 20.6 11.5 15.3 1.8 20.6 10.3 22 7 26 305 -17.2 0 -16.9 -17.3 12/17/2005 00:50:00 16.3 1.8 21.4 12.2 16 2 21.8 11.5 22 6 21 305 -17.2 0 -16.9 -17.3 12/17/2005 01:00:00 16.6 1.7 21 12.2 16.3 1.7 20.6 11.1 24 6 28 305 -17.3 0 -16.9 -17.3 12/17/2005 01:10:00 16.4 1.5 21 12.6 16 1.6 21 11.8 25 5 26 305 -17.1 0 -16.9 -17.3 12/17/2005 01:20:00 14 1.8 18.7 9.9 13.7 1.7 18.3 9.9 23 6 26 305 -17 0 -16.9 -17.3 12/17/2005 01:30:00 13.7 1.6 17.6 9.1 13.4 1.5 17.6 9.5 18 6 18 305 -17.1 0 -16.9 -17.3 12/17/2005 01:40:00 15.4 1.7 19.9 11.1 15.2 1.7 19.5 11.1 22 6 26 305 -17.1 0 -16.9 -17.3 12/17/2005 01:50:00 14.8 1.9 19.5 10.3 14.7 1.8 19.5 10.7 19 6 22 305 -17.2 0.1 -16.9 -17.5 12/17/2005 02:00:00 14.2 1.5 17.6 10.7 13.9 1.5 17.6 10.7 11 5 19 305 -17.8 0.1 -17.3 -18.1 12/17/2005 02:10:00 13.8 1.2 17.2 10.7 13.5 1.2 16.8 9.9 11 5 9 305 -17.9 0 -17.7 -18.1 12/17/2005 02:20:00 14.2 1.5 18.7 10.3 14 1.4 18.7 10.7 16 6 5 305 -17.7 0.1 -17.5 -18.1 12/17/2005 02:30:00 16.2 1.8 21 11.1 15.7 1.7 20.2 11.5 20 5 21 305 -17.5 0 -17.3 -17.7 12/17/2005 02:40:00 15.7 1.7 19.5 11.5 15.4 1.8 19.1 11.1 18 6 21 305 -17.5 0 -17.3 -17.7 12/17/2005 02:50:00 15.7 1.5 18.7 11.1 15.4 1.6 18.7 11.1 18 5 18 305 -17.5 0 -17.5 -17.7 12/17/2005 03:00:00 14.7 1.7 18.7 10.3 14.3 1.5 18.3 10.7 20 5 16 305 -17.5 0 -17.3 -17.7 12/17/2005 03:10:00 15.3 1.8 19.5 11.1 15.1 1.8 19.9 10.7 21 6 25 305 -17.5 0 -17.1 -17.5 12/17/2005 03:20:00 16.3 1.8 21 11.8 15.9 1.8 20.6 11.5 21 6 17 305 -17.5 0 -17.3 -17.7 12/17/2005 03:30:00 14.1 1.5 17.6 9.9 13.8 1.5 17.6 10.3 24 6 28 305 -17.5 0 -17.3 -17.5 12/17/2005 03:40:00 14.1 1.7 18.3 10.3 13.9 1.7 17.6 9.9 27 6 24 305 -17.5 0 -17.3 -17.5 12/17/2005 03:50:00 15.2 1.8 19.9 11.1 14.9 1.8 19.5 11.1 27 6 27 305 -17.5 0 -17.3 -17.7 12/17/2005 04:00:00 16.1 1.7 20.2 11.5 15.8 1.7 20.2 11.5 25 6 26 305 -17.5 0 -17.3 -17.7 12/17/2005 04:10:00 16.1 2.1 21.8 11.8 15.8 2 21 11.5 23 5 22 305 -17.5 0 -17.3 -17.7 12/17/2005 04:20:00 16.8 2.1 22.1 11.5 16.6 1.8 21.8 11.8 23 6 22 305 -17.6 0 -17.5 -17.9 12/17/2005 04:30:00 15 1.8 19.5 9.9 14.8 1.7 18.7 10.3 21 9 22 305 -17.6 0.1 -17.5 -18.1 12/17/2005 04:40:00 13.6 2 18.7 8.8 13.6 2 19.1 9.5 12 8 19 305 -18 0.2 -17.5 -18.4 12/17/2005 04:50:00 13.4 1.5 16.8 8.4 13.4 1.6 16.8 9.1 8 5 12 305 -18.4 0 -18.1 -18.4 12/17/2005 05:00:00 12.7 1.3 16.1 9.5 12.6 1.5 16.4 9.5 13 7 13 305 -18.1 0.1 -17.5 -18.4 12/17/2005 05:10:00 13.4 1.9 17.9 9.1 13.2 1.9 17.9 9.1 23 6 19 305 -17.4 0.1 -17.1 -17.7 12/17/2005 05:20:00 13.9 2.3 18.3 8.4 13.6 2.2 18.3 8.4 24 6 25 305 -17.3 0 -17.1 -17.5 12/17/2005 05:30:00 15.4 1.7 20.6 11.1 15.2 1.7 19.1 11.1 24 6 30 305 -17.3 0.1 -16.9 -17.5 12/17/2005 05:40:00 15.4 1.7 20.2 11.1 15.2 1.7 19.5 11.1 25 6 22 305 -17.2 0 -16.9 -17.5 12/17/2005 05:50:00 13.6 1.9 17.9 8.8 13.4 1.9 18.7 9.1 26 6 21 305 -17.1 0 -16.9 -17.3 12/17/2005 06:00:00 15 2 19.5 9.5 14.6 1.9 19.9 9.1 27 6 22 305 -17.1 0 -16.9 -17.3 12/17/2005 06:10:00 15.9 1.6 19.5 11.1 15.4 1.6 19.5 11.1 24 5 29 305 -17.2 0 -16.9 -17.3 12/17/2005 06:20:00 14.6 2 19.1 10.3 14.4 2 18.7 9.9 21 6 23 305 -17.1 0 -16.9 -17.3 12/17/2005 06:30:00 13.2 1.7 16.8 9.1 13.1 1.7 16.8 9.1 16 8 17 305 -17.1 0.1 -16.9 -17.5 12/17/2005 06:40:00 12.8 1.4 16.8 9.5 12.7 1.3 16.8 8.8 7 5 3 305 -17.8 0.1 -17.3 -18.1 12/17/2005 06:50:00 13.8 1.5 16.8 9.9 13.6 1.5 16.8 9.9 12 8 9 305 -17.6 0.4 -16.9 -18.1 12/17/2005 07:00:00 13.8 1.3 17.6 10.7 13.7 1.3 16.8 10.7 6 6 8 305 -18 0 -17.9 -18.1 12/17/2005 07:10:00 12.6 1.2 16.1 9.5 12.6 1.2 15.6 9.1 6 6 357 305 -17.8 0 -17.5 -18.1 12/17/2005 07:20:00 11.1 1.2 13.7 8.4 11 1.2 14.1 8 6 6 14 305 -17.6 0 -17.5 -17.7 12/17/2005 07:30:00 11.7 1.6 16.1 8.8 11.6 1.6 15.6 8.4 16 7 5 305 -17.1 0.2 -16.9 -17.7 12/17/2005 07:40:00 12.8 1.4 16.1 8.4 12.5 1.4 16.1 8.8 17 6 9 305 -16.9 0 -16.9 -16.9 12/17/2005 07:50:00 12.9 1.6 16.4 8.4 12.6 1.6 16.8 8.8 21 6 22 305 -16.9 0 -16.9 -16.9 12/17/2005 08:00:00 12.5 1.1 15.3 9.5 12.3 1.2 14.9 8.8 17 5 20 305 -16.9 0 -16.9 -16.9 12/17/2005 08:10:00 12.7 1.3 15.6 9.5 12.6 1.2 15.3 8.8 15 6 13 305 -16.9 0 -16.9 -16.9 12/17/2005 08:20:00 13 1.2 15.3 9.5 12.6 1.2 15.3 9.1 16 5 14 305 -16.9 0 -16.9 -16.9 12/17/2005 08:30:00 13.1 1.5 16.1 8.8 12.9 1.5 16.4 8.8 16 5 13 305 -16.9 0 -16.9 -16.9 12/17/2005 08:40:00 12.2 1.3 15.3 8.4 12 1.2 15.3 8 18 6 31 305 -17 0 -16.9 -17.1 12/17/2005 08:50:00 13.1 1.6 17.2 9.1 13.1 1.6 17.2 9.1 19 6 25 305 -17 0 -16.9 -17.1 12/17/2005 09:00:00 12.6 1.6 16.4 8.4 12.5 1.5 16.8 8.8 4 12 18 305 -17.5 0.5 -16.9 -18.1 12/17/2005 09:10:00 12.3 1.6 16.1 8.8 12.3 1.6 16.4 8.8 357 5 2 305 -18.2 0.1 -18.1 -18.4 12/17/2005 09:20:00 13.1 1.3 16.8 9.9 13.1 1.2 16.1 9.9 356 5 351 305 -18.5 0 -18.4 -18.4 12/17/2005 09:30:00 13 1.8 17.2 9.1 12.9 1.8 17.6 9.1 357 6 356 305 -18.6 0 -18.4 -18.8 12/17/2005 09:40:00 13.7 1.3 16.8 9.9 13.7 1.3 16.4 9.9 0 4 356 305 -18.6 0 -18.4 -18.8 12/17/2005 09:50:00 12.7 1.5 15.6 9.1 12.6 1.5 16.8 8.8 357 6 359 305 -18.5 0 -18.2 -18.4 12/17/2005 10:00:00 13.2 1.2 16.1 9.9 13.1 1.3 16.1 9.1 357 6 359 305 -18.5 0 -18.1 -18.6 12/17/2005 10:10:00 13.1 1.7 16.4 9.1 13 1.7 16.8 8.8 358 6 357 305 -18.5 0 -18.4 -18.6 12/17/2005 10:20:00 13.1 1.5 16.1 8.8 13 1.5 16.4 9.1 0 5 359 305 -18.5 0 -18.4 -18.6 12/17/2005 10:30:00 13.5 1.4 17.2 9.9 13.4 1.4 17.2 10.3 0 5 13 305 -18.4 0 -18.2 -18.4 12/17/2005 10:40:00 13.7 1.4 17.2 10.3 13.6 1.4 17.6 9.5 357 6 355 305 -18.5 0 -18.2 -18.6 12/17/2005 10:50:00 13.4 1.4 16.8 9.5 13.3 1.4 16.8 9.9 358 5 351 305 -18.5 0 -18.2 -18.6 12/17/2005 11:00:00 14 1.8 17.6 9.1 13.8 1.7 17.6 9.1 357 6 358 305 -18.4 0 -18.1 -18.4 12/17/2005 11:10:00 12.8 1.6 16.8 9.1 12.8 1.5 17.2 9.5 355 5 348 305 -18.4 0 -18.2 -18.4 12/17/2005 11:20:00 13.4 1.6 16.8 9.1 13.6 1.5 16.8 9.1 356 5 351 305 -18.6 0 -18.4 -18.6 12/17/2005 11:30:00 12.7 1.5 16.4 9.1 12.5 1.5 16.4 9.1 358 6 355 305 -18.4 0 -18.2 -18.4 12/17/2005 11:40:00 12.4 1.3 15.6 9.1 12.2 1.4 15.3 8.4 1 6 358 305 -18.4 0 -18.2 -18.4 12/17/2005 11:50:00 12.5 1.6 15.6 8.4 12.4 1.5 15.6 8.8 4 5 3 305 -18.3 0 -18.1 -18.4 12/17/2005 12:00:00 11.3 1.5 14.9 8 11.3 1.6 14.5 8 1 6 2 305 -18.3 0 -18.1 -18.4 12/17/2005 12:10:00 11.5 1.4 14.9 8.4 11.6 1.2 14.9 9.1 0 6 0 305 -18.4 0 -18.2 -18.4 12/17/2005 12:20:00 11.8 1.5 14.5 7.6 11.9 1.3 14.9 8 359 5 359 305 -18.5 0 -18.2 -18.4 12/17/2005 12:30:00 10.6 1.3 14.1 7.2 10.6 1.2 14.5 8 359 6 358 305 -18.5 0 -18.4 -18.6 12/17/2005 12:40:00 11.2 1.2 13.3 8 11.2 1.2 13.7 8.4 0 5 359 305 -18.6 0 -18.4 -18.6 12/17/2005 12:50:00 11.4 1.2 14.1 8 11.4 1.2 14.5 8.8 359 5 358 305 -18.7 0 -18.4 -18.8 12/17/2005 13:00:00 12.2 1.1 14.5 9.5 12.1 1.1 14.9 9.5 0 5 1 305 -18.7 0 -18.4 -18.8 12/17/2005 13:10:00 11.8 1.3 14.9 8.4 11.8 1.3 14.9 8 359 6 2 305 -18.8 0 -18.6 -19 12/17/2005 13:20:00 11.1 1.1 13.7 8.4 11 1.1 13.7 8.4 359 5 351 305 -18.8 0 -18.6 -19 12/17/2005 13:30:00 11.2 1.1 14.1 8 11.1 1.1 14.1 8.4 358 5 2 305 -18.8 0 -18.6 -19 12/17/2005 13:40:00 10.2 1.3 13.7 7.2 10.2 1.3 13.3 7.2 3 6 356 305 -18.8 0 -18.4 -19 12/17/2005 13:50:00 10.8 1.3 13.3 6.8 10.7 1.3 13.7 7.2 6 5 3 305 -18.8 0 -18.6 -19 12/17/2005 14:00:00 11.2 1.1 13.7 7.6 11.1 1 13.7 8.4 9 5 5 305 -18.8 0 -18.6 -19 12/17/2005 14:10:00 11.6 1.3 14.9 8 11.4 1.3 15.6 8 7 6 8 305 -18.8 0 -18.6 -19 12/17/2005 14:20:00 12.1 1.2 14.9 9.5 12 1.2 14.5 9.1 7 5 16 305 -18.8 0 -18.6 -19 12/17/2005 14:30:00 10.8 1.2 13.3 8.4 10.7 1.3 13.7 7.6 7 5 11 305 -18.8 0 -18.4 -19 12/17/2005 14:40:00 10.5 1.2 13.3 7.2 10.5 1.2 13 6.8 8 5 9 305 -18.8 0 -18.6 -19 12/17/2005 14:50:00 10.2 1.5 13.3 6.8 10.2 1.4 13.3 6.8 8 5 5 305 -18.8 0 -18.6 -19 12/17/2005 15:00:00 10.2 1.1 13.3 7.6 10.2 1.1 13 7.2 10 5 11 305 -18.8 0 -18.6 -19 12/17/2005 15:10:00 11.3 1 13.7 8.4 11.3 1 13.7 8.8 8 5 5 305 -18.9 0 -18.4 -19 12/17/2005 15:20:00 10.6 1.2 13.3 7.6 10.7 1.2 13.3 7.6 9 5 10 305 -19 0 -18.8 -19 12/17/2005 15:30:00 11.2 1.2 14.1 7.6 11.2 1.2 14.1 7.6 8 5 9 305 -19 0 -18.8 -19 12/17/2005 15:40:00 11.1 1.4 14.5 6.5 11.1 1.6 14.5 6.8 7 5 7 305 -19.1 0 -19 -19.2 12/17/2005 15:50:00 12.5 1.3 15.3 9.1 12.5 1.2 15.3 9.9 10 6 7 305 -19 0 -18.8 -19 12/17/2005 16:00:00 12.2 1.3 14.9 7.6 12.2 1.4 15.3 8.4 11 6 17 305 -18.9 0 -18.6 -19 12/17/2005 16:10:00 12.4 1.2 14.9 9.1 12.4 1.3 14.9 9.5 13 4 12 305 -18.9 0 -18.6 -19 12/17/2005 16:20:00 11.5 1.3 14.1 8.4 11.3 1.4 14.5 8 10 5 6 305 -18.9 0 -18.8 -19 12/17/2005 16:30:00 12.4 1.1 14.9 8.8 12.5 1 14.5 9.1 10 5 17 305 -19 0 -18.8 -19 12/17/2005 16:40:00 12.4 1.1 15.3 9.9 12.3 1.2 14.9 9.1 13 5 14 305 -19 0 -18.8 -19.2 12/17/2005 16:50:00 11.5 1.5 14.5 7.6 11.5 1.5 14.5 8 12 6 8 305 -19 0.1 -18.8 -19 12/17/2005 17:00:00 11.5 1.6 14.1 7.2 11.6 1.6 14.1 7.2 7 6 0 305 -19 0 -18.8 -19.2 12/17/2005 17:10:00 12.1 1.2 14.9 9.1 12.1 1.3 14.9 8.4 12 6 13 305 -19 0 -18.8 -19.2 12/17/2005 17:20:00 11.9 1.2 14.9 9.1 11.9 1.2 14.9 9.1 12 5 12 305 -19.1 0 -19 -19.2 12/17/2005 17:30:00 10.5 1.2 13.7 7.6 10.5 1.3 14.9 8 11 5 6 305 -19.1 0 -19 -19.2 12/17/2005 17:40:00 11 1.2 13.3 8 11 1.3 13.7 7.6 10 5 12 305 -19.1 0 -19 -19.2 12/17/2005 17:50:00 10.5 1.1 13 7.2 10.5 1.1 13.3 8 8 5 9 305 -19.1 0 -19 -19.2 12/17/2005 18:00:00 10.4 1.3 13.7 7.6 10.5 1.3 13.7 7.2 10 5 7 305 -19.2 0 -19 -19.3 12/17/2005 18:10:00 10.7 1.2 13.7 7.2 10.5 1.3 13.7 7.2 12 5 4 305 -19.2 0 -19 -19.3 12/17/2005 18:20:00 10 1.3 13 7.2 10 1.2 12.6 6.8 9 6 9 305 -19.3 0 -19.2 -19.5 12/17/2005 18:30:00 10.4 1.1 13 7.2 10.5 1.1 13.3 7.2 8 5 6 305 -19.3 0 -18.8 -19.5 12/17/2005 18:40:00 10.6 1 12.6 7.6 10.5 1 13 7.2 7 5 10 305 -19.4 0 -19.2 -19.5 12/17/2005 18:50:00 8.8 1.3 12.6 5.7 8.9 1.3 12.6 6.1 8 7 4 305 -19.4 0 -19.2 -19.5 12/17/2005 19:00:00 9.2 1.2 11.8 6.5 9.2 1.3 12.6 6.8 5 6 15 305 -19.4 0 -19.2 -19.5 12/17/2005 19:10:00 9.4 1.1 12.2 6.8 9.3 1.1 12.6 6.8 7 6 3 305 -19.4 0 -19.3 -19.5 12/17/2005 19:20:00 9.9 0.9 12.2 7.2 9.8 1 12.2 7.2 7 5 4 305 -19.5 0 -19.3 -19.5 12/17/2005 19:30:00 10.3 1 12.2 7.2 10.2 1.1 12.2 7.2 9 5 8 305 -19.6 0 -19.3 -19.7 12/17/2005 19:40:00 10.4 1 12.2 8 10.2 1.1 13 8 7 5 7 305 -19.6 0 -19.5 -19.7 12/17/2005 19:50:00 10.4 1.2 13.3 6.8 10.4 1.2 13 6.8 6 5 1 305 -19.7 0 -19.5 -19.7 12/17/2005 20:00:00 10 1.3 13.3 6.8 9.9 1.3 13.3 6.8 5 5 9 305 -19.6 0 -19.5 -19.7 12/17/2005 20:10:00 9.5 1.2 13 6.8 9.4 1.2 13.3 6.5 9 6 3 305 -19.5 0 -19.3 -19.5 12/17/2005 20:20:00 8.6 1.1 11.1 5.7 8.4 1.1 11.1 5.7 7 6 17 305 -19.5 0.1 -19.3 -19.5 12/17/2005 20:30:00 10 1.1 12.2 7.2 9.9 1.1 12.6 7.2 10 5 10 305 -19.4 0 -19.3 -19.5 12/17/2005 20:40:00 9.7 1.6 13.3 6.1 9.7 1.4 12.6 6.5 16 6 9 305 -19.4 0 -19.3 -19.5 12/17/2005 20:50:00 10.7 1.2 13.7 7.6 10.5 1.1 13 6.8 12 5 22 305 -19.4 0 -19.3 -19.5 12/17/2005 21:00:00 9.9 1 12.6 7.2 9.7 1.1 13 7.6 12 6 10 305 -19.4 0 -19.2 -19.5 12/17/2005 21:10:00 9.7 1.3 12.2 6.8 9.5 1.4 12.2 6.1 11 6 14 305 -19.3 0 -19.2 -19.5 12/17/2005 21:20:00 9 1.2 11.5 6.1 8.9 1.2 11.8 6.1 14 7 17 305 -19.3 0 -19.2 -19.5 12/17/2005 21:30:00 9.1 1.4 11.8 6.1 8.9 1.3 11.8 6.1 15 6 26 305 -19.3 0 -19 -19.5 12/17/2005 21:40:00 9.8 0.9 11.5 7.2 9.6 1 12.2 6.5 14 6 21 305 -19.2 0 -18.8 -19.3 12/17/2005 21:50:00 9 1.1 11.5 6.1 8.9 1 11.8 6.1 13 6 10 305 -19.1 0 -19 -19.2 12/17/2005 22:00:00 8.6 1.2 11.5 5.7 8.4 1.2 11.8 5.7 15 6 10 305 -19.1 0 -18.6 -19.2 12/17/2005 22:10:00 8.5 1 11.1 5.7 8.4 1.1 11.1 5.3 13 5 12 305 -19 0 -18.8 -19 12/17/2005 22:20:00 8.9 1.1 11.8 6.1 8.8 1.1 11.8 6.5 13 6 12 305 -18.9 0 -18.8 -19 12/17/2005 22:30:00 9.2 1.3 11.8 6.5 9.1 1.2 11.8 6.1 12 6 9 305 -18.8 0 -18.6 -19 12/17/2005 22:40:00 9.7 1.1 12.2 6.5 9.7 1.1 12.2 6.8 13 6 17 305 -18.8 0 -18.6 -19 12/17/2005 22:50:00 8.7 1.3 11.5 5.7 8.6 1.2 11.8 5.7 19 6 21 305 -18.8 0 -18.6 -19 12/17/2005 23:00:00 9.5 1 11.8 7.2 9.3 1 11.8 6.5 17 5 16 305 -18.9 0 -18.4 -19 12/17/2005 23:10:00 8.8 1.1 11.1 5.7 8.6 1.1 11.5 5.7 19 6 25 305 -18.8 0 -18.6 -19 12/17/2005 23:20:00 8 0.9 10.3 5.7 7.8 0.8 10.3 6.1 18 6 21 305 -18.9 0 -18.8 -19 12/17/2005 23:30:00 8.8 1.1 11.5 6.1 8.6 1 11.5 6.5 17 6 11 305 -18.9 0 -18.6 -19 12/17/2005 23:40:00 9.3 1 11.8 6.1 9 1 11.5 6.1 17 6 10 305 -18.8 0 -18.6 -19 12/17/2005 23:50:00 8.8 1 11.1 6.5 8.6 1 11.1 5.7 18 5 16 305 -18.8 0 -18.6 -19 12/18/2005 00:00:00 7.9 1 10.7 5.7 7.8 1 11.1 5.7 18 6 12 305 -18.8 0 -18.4 -19 12/18/2005 00:10:00 9.1 1 11.5 6.1 8.9 1.1 11.8 6.5 17 6 17 305 -18.8 0 -18.6 -19 12/18/2005 00:20:00 9.5 1 11.8 6.5 9.2 1 12.2 6.8 18 5 12 305 -18.7 0 -18.4 -19 12/18/2005 00:30:00 9.3 1.1 11.5 6.5 9.1 1 11.8 6.5 17 5 14 305 -18.7 0 -18.4 -19 12/18/2005 00:40:00 8.9 1 11.1 6.5 8.7 1.1 11.5 6.5 18 5 10 305 -18.8 0 -18.4 -19 12/18/2005 00:50:00 9.6 1.1 12.2 6.8 9.4 1 12.2 6.8 17 5 26 305 -18.8 0 -18.6 -19 12/18/2005 01:00:00 10.4 1.3 13.3 7.2 10.1 1.3 13.3 6.8 16 5 16 305 -18.9 0 -18.8 -19 12/18/2005 01:10:00 10.8 1.2 13.3 7.6 10.5 1.1 13 8 17 5 15 305 -18.8 0 -18.8 -19 12/18/2005 01:20:00 10.7 1.4 13.3 6.1 10.4 1.3 13.3 7.2 16 5 19 305 -18.9 0 -18.4 -19 12/18/2005 01:30:00 10.8 1.1 13.3 7.6 10.7 1.1 13.7 7.6 16 5 16 305 -18.9 0 -18.8 -19 12/18/2005 01:40:00 10.5 1 13 7.2 10.4 1.1 13.3 7.6 16 6 15 305 -18.9 0 -18.8 -19 12/18/2005 01:50:00 10.3 1.3 13.7 6.5 10.2 1.3 13.3 6.8 18 5 14 305 -19 0 -18.8 -19 12/18/2005 02:00:00 10.7 1 13 8.4 10.6 1 13.3 8 17 5 16 305 -19.1 0 -19 -19.2 12/18/2005 02:10:00 10 1.2 13 6.8 9.9 1.2 13 6.5 17 5 13 305 -19.1 0 -19 -19.2 12/18/2005 02:20:00 10.4 1 12.6 7.6 10.2 1 12.6 7.6 15 6 21 305 -19.1 0 -19 -19 12/18/2005 02:30:00 10.2 1.1 12.2 7.2 10.1 1.2 13 6.8 15 5 11 305 -19.1 0 -19 -19.2 12/18/2005 02:40:00 10 1.2 12.6 6.8 9.8 1.2 12.6 6.8 16 5 20 305 -19.1 0 -19 -19.2 12/18/2005 02:50:00 9.3 1.2 12.2 6.8 9.2 1.1 12.2 6.5 18 6 18 305 -19 0 -18.8 -19 12/18/2005 03:00:00 9.5 1.2 12.2 6.1 9.4 1.3 12.2 6.1 17 6 13 305 -18.9 0 -18.8 -19 12/18/2005 03:10:00 9.5 1.1 12.2 6.8 9.3 1.2 12.6 6.5 17 6 12 305 -18.9 0 -18.8 -19 12/18/2005 03:20:00 9.2 1.1 12.2 6.5 9.1 1.1 11.8 6.5 14 6 9 305 -18.8 0 -18.6 -19 12/18/2005 03:30:00 9.3 1 11.8 6.8 9.1 1 11.8 6.8 15 6 13 305 -18.7 0 -18.4 -19 12/18/2005 03:40:00 9.7 1.2 12.2 6.8 9.5 1.2 11.8 7.2 14 6 17 305 -18.5 0 -18.4 -18.6 12/18/2005 03:50:00 10.3 1.2 12.6 6.8 10 1.3 12.6 7.2 12 5 15 305 -18.5 0 -18.4 -18.4 12/18/2005 04:00:00 10.4 1.1 12.6 7.2 10.3 1.1 13 7.2 12 5 8 305 -18.4 0 -18.2 -18.4 12/18/2005 04:10:00 9.8 1.1 13 6.8 9.8 1.1 13 6.8 11 5 19 305 -18.4 0 -18.2 -18.4 12/18/2005 04:20:00 10.4 1 12.6 7.6 10.4 1 12.6 8 9 5 11 305 -18.4 0 -18.2 -18.4 12/18/2005 04:30:00 10.4 1.1 12.6 7.6 10.3 1.2 12.6 7.6 10 5 11 305 -18.4 0 -18.2 -18.4 12/18/2005 04:40:00 8.6 1.1 11.8 6.1 8.5 1 11.5 6.1 16 6 28 305 -18.3 0 -18.2 -18.4 12/18/2005 04:50:00 9 0.9 11.1 7.2 8.9 0.9 11.5 6.5 22 7 18 305 -18.1 0.1 -17.7 -18.4 12/18/2005 05:00:00 9.6 1.1 11.8 6.8 9.6 1.2 12.2 6.1 25 6 22 305 -17.9 0 -17.7 -18.1 12/18/2005 05:10:00 10 1.1 12.6 6.8 9.9 1.1 12.6 6.8 26 6 32 305 -17.8 0 -17.7 -18.1 12/18/2005 05:20:00 10.3 1.1 13 6.8 10.2 1.1 13 6.8 25 6 29 305 -17.8 0 -17.7 -18.1 12/18/2005 05:30:00 11.8 1 13.7 8.8 11.6 1 14.1 8.8 26 5 26 305 -17.8 0 -17.7 -18.1 12/18/2005 05:40:00 12.4 1 14.5 8.8 12.2 1 14.1 9.1 26 5 15 305 -17.8 0 -17.7 -18.1 12/18/2005 05:50:00 11.2 1.2 14.1 8 11 1.2 13.7 7.6 29 6 31 305 -17.9 0 -17.5 -18.1 12/18/2005 06:00:00 11 1.1 13.7 8.4 10.8 1.1 13.3 7.6 28 6 25 305 -17.8 0 -17.5 -17.9 12/18/2005 06:10:00 10.4 1.1 13 7.6 10.3 1.1 13 8 28 6 24 305 -17.8 0 -17.5 -18.1 12/18/2005 06:20:00 10.2 1.2 13.3 7.6 10 1.2 13.7 7.2 31 6 23 305 -17.7 0 -17.5 -17.9 12/18/2005 06:30:00 10.7 1 12.6 8 10.4 1 13.3 7.6 29 5 27 305 -17.6 0 -17.5 -17.9 12/18/2005 06:40:00 10.3 1.1 13 7.6 10 1.2 12.6 7.2 26 5 28 305 -17.5 0 -17.3 -17.7 12/18/2005 06:50:00 10.5 1 12.6 7.6 10.4 1 12.2 7.6 30 5 27 305 -17.5 0 -17.5 -17.7 12/18/2005 07:00:00 10 1.2 12.2 6.8 9.8 1.3 12.6 6.5 34 6 35 305 -17.6 0 -17.5 -17.9 12/18/2005 07:10:00 10.3 0.9 12.6 8.4 10.1 1 13 7.2 35 5 32 305 -17.8 0 -17.5 -17.9 12/18/2005 07:20:00 10.3 1 12.6 7.6 10.1 1.1 12.6 7.6 37 5 35 305 -17.8 0 -17.7 -17.9 12/18/2005 07:30:00 10.6 1 13 7.6 10.4 1 13 8 33 5 37 305 -17.9 0 -17.7 -18.1 12/18/2005 07:40:00 10.2 1 12.6 7.6 9.9 1 12.2 7.2 31 5 33 305 -18 0 -17.9 -18.1 12/18/2005 07:50:00 11.3 0.9 13.3 8.8 11.1 1 13.3 7.6 36 4 32 305 -18.1 0 -17.9 -18.2 12/18/2005 08:00:00 11.3 0.8 13.7 9.1 11 0.9 13.3 8.8 35 5 42 305 -18.2 0 -18.1 -18.4 12/18/2005 08:10:00 12.5 1 14.9 9.5 12.2 1 14.5 9.1 33 5 31 305 -18.3 0 -18.1 -18.4 12/18/2005 08:20:00 11.9 1 14.5 8.8 11.6 1 14.5 8 35 5 34 305 -18.4 0 -18.1 -18.4 12/18/2005 08:30:00 12.1 1.2 14.5 9.5 11.8 1.3 14.5 8.8 34 6 23 305 -18.4 0 -18.2 -18.4 12/18/2005 08:40:00 12.8 1.1 14.9 9.9 12.5 1.2 15.3 9.1 34 5 34 305 -18.4 0 -18.2 -18.4 12/18/2005 08:50:00 13.3 1.1 15.6 9.9 12.9 1.1 15.3 9.5 33 5 35 305 -18.4 0 -18.2 -18.4 12/18/2005 09:00:00 13.1 1.1 16.4 10.3 12.8 1.2 15.6 9.1 32 4 33 305 -18.5 0 -18.4 -18.6 12/18/2005 09:10:00 13.4 1.1 16.1 10.3 13.2 1.1 16.1 10.3 35 4 32 305 -18.5 0 -18.4 -18.4 12/18/2005 09:20:00 13.7 1 15.6 11.1 13.4 1.1 16.1 10.3 33 5 32 305 -18.5 0 -18.4 -18.6 12/18/2005 09:30:00 12.4 0.9 14.5 9.1 12.1 1 14.5 9.5 33 5 33 305 -18.6 0 -18.4 -18.6 12/18/2005 09:40:00 13.1 1.2 16.1 9.9 12.7 1.2 15.6 9.5 35 4 33 305 -18.6 0 -18.4 -18.6 12/18/2005 09:50:00 13.7 1.4 16.8 9.9 13.4 1.5 17.2 9.5 38 5 35 305 -18.6 0 -18.4 -18.6 12/18/2005 10:00:00 13.2 1.5 16.8 9.5 13 1.5 16.8 9.9 36 5 33 305 -18.5 0 -18.4 -18.6 12/18/2005 10:10:00 12.6 1.2 15.6 9.5 12.5 1.2 16.1 9.5 40 6 37 305 -18.5 0 -18.4 -18.8 12/18/2005 10:20:00 12.2 1.3 15.6 9.1 11.9 1.5 15.6 8.4 41 6 38 305 -18.7 0 -18.4 -18.8 12/18/2005 10:30:00 12.4 1 15.3 9.9 12.3 1 15.3 9.9 40 6 43 305 -18.7 0 -18.4 -19 12/18/2005 10:40:00 14.2 1.2 16.8 11.5 14 1.2 16.8 11.1 36 5 38 305 -18.6 0 -18.4 -18.6 12/18/2005 10:50:00 14.6 1.1 17.6 11.1 14.3 1.2 17.2 10.7 37 5 36 305 -18.5 0 -18.4 -18.6 12/18/2005 11:00:00 12.6 1.1 15.6 9.5 12.5 1.2 16.1 9.1 38 6 49 305 -18.5 0 -18.4 -18.6 12/18/2005 11:10:00 12.8 1.2 16.4 9.5 12.6 1.3 16.4 9.9 40 5 37 305 -18.5 0 -18.4 -18.6 12/18/2005 11:20:00 13.2 1 15.6 10.7 13.1 1.1 16.1 10.3 41 5 43 305 -18.6 0 -18.4 -18.6 12/18/2005 11:30:00 13.8 1.2 16.1 11.1 13.5 1.3 16.8 10.7 38 6 41 305 -18.5 0 -18.2 -18.6 12/18/2005 11:40:00 13.7 1.5 16.4 10.3 13.3 1.6 17.2 9.1 38 6 40 305 -18.3 0 -18.1 -18.4 12/18/2005 11:50:00 13.1 1.5 17.6 9.1 13 1.5 17.6 9.5 45 6 38 305 -18.4 0 -18.2 -18.4 12/18/2005 12:00:00 13.7 1.2 17.2 10.3 13.4 1.3 17.6 9.9 45 6 49 305 -18.6 0 -18.4 -18.8 12/18/2005 12:10:00 13.1 1.6 16.8 9.1 12.9 1.7 17.2 9.1 44 5 36 305 -18.6 0 -18.4 -18.8 12/18/2005 12:20:00 11.7 1.5 15.6 8 11.6 1.5 15.3 8.4 46 6 45 305 -18.9 0 -18.6 -19 12/18/2005 12:30:00 11.4 1.1 14.1 8.8 11.2 1.1 13.7 8.8 47 6 48 305 -19 0 -18.8 -19 12/18/2005 12:40:00 11.6 0.9 14.1 9.1 11.4 1 14.1 9.1 46 5 41 305 -19.1 0 -18.4 -19.2 12/18/2005 12:50:00 12.2 1.3 15.6 8.8 11.9 1.4 15.6 8.4 45 6 50 305 -19.1 0 -19 -19.2 12/18/2005 13:00:00 12.5 1.3 16.4 9.5 12.4 1.2 16.4 9.5 43 6 39 305 -19.2 0 -19 -19.3 12/18/2005 13:10:00 13 1.5 17.2 8.8 12.7 1.4 16.4 9.1 43 6 52 305 -19.1 0 -19 -19.2 12/18/2005 13:20:00 13.2 1.5 16.1 9.5 13 1.5 16.1 9.1 39 6 37 305 -19.1 0 -18.4 -19.2 12/18/2005 13:30:00 13.4 1.3 16.4 9.9 13.2 1.4 16.4 9.9 35 5 29 305 -19.1 0 -19 -19.2 12/18/2005 13:40:00 12.4 1.2 16.1 9.5 12.2 1.3 16.4 9.5 37 6 33 305 -19.1 0 -19 -19.3 12/18/2005 13:50:00 13.8 1.3 16.4 10.7 13.5 1.3 16.4 9.9 36 5 35 305 -19.1 0 -19 -19.2 12/18/2005 14:00:00 14 1.3 17.2 10.3 13.7 1.5 17.6 9.5 37 5 33 305 -19.2 0 -19 -19.3 12/18/2005 14:10:00 13.2 1.5 17.2 9.9 12.9 1.6 17.6 9.5 37 6 40 305 -19.1 0 -19 -19.2 12/18/2005 14:20:00 14.1 1.5 17.9 10.3 13.8 1.5 17.6 9.9 37 7 42 305 -19.1 0 -19 -19.2 12/18/2005 14:30:00 14.8 1.3 17.9 11.1 14.5 1.3 17.6 10.7 32 5 35 305 -19.1 0 -19 -19.2 12/18/2005 14:40:00 15.3 1.7 19.5 11.1 15.1 1.7 19.5 11.1 32 5 35 305 -19.1 0 -19 -19.2 12/18/2005 14:50:00 15.4 1.3 19.1 12.6 15 1.3 18.7 11.1 36 5 31 305 -19.1 0 -19 -19 12/18/2005 15:00:00 14.5 1.3 17.6 11.5 14.3 1.3 17.6 11.5 37 5 50 305 -19 0 -18.8 -19 12/18/2005 15:10:00 16 1.5 20.2 11.8 15.9 1.4 19.1 12.2 34 4 37 305 -19 0 -18.8 -19 12/18/2005 15:20:00 14.8 1.5 19.1 11.8 14.3 1.5 18.3 10.7 33 5 27 305 -19 0 -18.8 -19 12/18/2005 15:30:00 14.3 1.3 17.9 10.7 13.9 1.4 17.6 10.3 32 5 29 305 -19 0 -18.8 -19 12/18/2005 15:40:00 14.5 1.8 18.3 10.7 14.3 1.7 18.3 10.3 37 6 37 305 -19 0 -19 -19 12/18/2005 15:50:00 13 1.6 18.3 9.5 12.6 1.5 18.3 9.5 37 5 34 305 -19 0 -19 -19.2 12/18/2005 16:00:00 13 1.4 16.4 9.9 12.9 1.4 17.2 9.9 38 6 28 305 -19.1 0 -18.8 -19.2 12/18/2005 16:10:00 12.9 1 16.1 9.9 12.6 1 15.6 9.9 37 6 33 305 -19.1 0 -18.8 -19.2 12/18/2005 16:20:00 13 1.2 16.1 9.9 12.8 1.2 16.4 9.9 39 6 47 305 -19.1 0 -19 -19.2 12/18/2005 16:30:00 12.7 1 15.6 9.9 12.3 1.1 15.3 9.5 38 6 40 305 -19.1 0 -19 -19.2 12/18/2005 16:40:00 13.2 1.5 17.6 9.5 12.9 1.4 17.2 9.5 39 6 33 305 -19.1 0 -19 -19.2 12/18/2005 16:50:00 13.8 1.1 16.8 10.7 13.6 1.2 16.8 10.7 42 5 44 305 -19.2 0 -19 -19.3 12/18/2005 17:00:00 14.1 1 16.4 10.7 13.8 1.2 16.8 10.3 44 5 45 305 -19.3 0 -19.2 -19.5 12/18/2005 17:10:00 13.2 1.2 16.4 10.3 13.1 1.3 16.4 9.9 45 5 47 305 -19.3 0 -18.8 -19.5 12/18/2005 17:20:00 13.7 1.1 16.4 11.1 13.4 1.2 16.8 10.7 44 5 46 305 -19.4 0 -19.2 -19.5 12/18/2005 17:30:00 13.6 1 16.4 10.7 13.3 1.1 16.1 10.3 46 5 56 305 -19.4 0 -19.3 -19.5 12/18/2005 17:40:00 13.8 1.3 17.2 10.7 13.6 1.4 17.6 10.3 47 5 50 305 -19.5 0 -19.3 -19.5 12/18/2005 17:50:00 14.3 1.1 17.2 10.7 14.1 1.3 16.8 10.7 48 5 51 305 -19.5 0 -19.3 -19.5 12/18/2005 18:00:00 14.4 1.4 17.9 10.3 14.1 1.4 17.9 9.9 45 6 43 305 -19.5 0 -19.3 -19.5 12/18/2005 18:10:00 13.1 1.3 17.6 10.3 12.8 1.4 17.6 9.5 46 5 48 305 -19.6 0 -19.3 -19.7 12/18/2005 18:20:00 14.6 1.3 18.7 11.1 14.3 1.3 17.6 11.1 44 5 36 305 -19.6 0 -19.5 -19.7 12/18/2005 18:30:00 15.6 1.5 20.2 11.8 15.3 1.6 19.9 11.5 41 6 48 305 -19.6 0 -19.3 -19.7 12/18/2005 18:40:00 16.9 1.5 19.9 13 16.6 1.6 20.2 13 39 5 38 305 -19.4 0 -19.2 -19.5 12/18/2005 18:50:00 17.2 2 22.1 12.6 16.9 2 21.8 13 37 6 41 305 -19.2 0 -19 -19.5 12/18/2005 19:00:00 16.7 1.8 21.4 12.6 16.4 1.8 21.8 13 41 6 37 305 -19.1 0 -19 -19.2 12/18/2005 19:10:00 16.9 1.5 21 13.3 16.6 1.5 20.2 12.2 40 5 24 305 -19.1 0 -19 -19.2 12/18/2005 19:20:00 16.7 1.7 20.6 12.2 16.5 1.7 20.6 12.2 40 6 42 305 -19.1 0 -19 -19 12/18/2005 19:30:00 16.5 1.7 20.6 12.6 16.2 1.7 19.9 12.2 40 5 31 305 -19 0 -18.8 -19 12/18/2005 19:40:00 16.4 1.2 19.9 12.6 16 1.3 19.9 13 41 5 44 305 -18.8 0 -18.6 -19 12/18/2005 19:50:00 16.2 1.6 20.2 13 16 1.6 21 13 41 5 44 305 -18.8 0 -18.6 -19 12/18/2005 20:00:00 18 1.5 21.4 14.5 17.7 1.5 21.4 14.1 37 4 36 305 -18.7 0 -18.4 -19 12/18/2005 20:10:00 16.3 1.5 19.5 12.6 16.1 1.5 19.1 13 44 5 43 305 -18.8 0 -18.6 -19 12/18/2005 20:20:00 18.4 1.9 22.9 14.1 18.1 2 22.6 13.3 45 5 41 305 -18.8 0 -18.6 -19 12/18/2005 20:30:00 17.4 1.7 22.1 13 17.1 1.7 22.1 13 42 5 38 305 -18.7 0 -18.4 -19 12/18/2005 20:40:00 18.1 1.9 22.6 14.1 17.8 1.8 21.8 13.3 40 5 38 305 -18.7 0 -18.4 -19 12/18/2005 20:50:00 17.7 1.7 22.1 13.7 17.4 1.8 21 13.3 44 5 47 305 -18.8 0 -18.6 -19 12/18/2005 21:00:00 19 1.7 24.8 14.5 18.9 1.8 25.6 14.5 44 5 39 305 -18.8 0 -18.4 -19 12/18/2005 21:10:00 20.9 1.9 25.2 14.9 20.6 2 25.6 14.9 44 4 38 305 -18.8 0 -18.6 -19 12/18/2005 21:20:00 18.3 1.7 22.9 14.1 18.1 1.7 22.9 13.7 48 5 46 305 -19 0 -18.8 -19.2 12/18/2005 21:30:00 19.3 1.6 23.7 15.3 19 1.7 23.3 14.5 48 6 36 305 -19.1 0 -19 -19.2 12/18/2005 21:40:00 19.1 1.6 23.3 14.5 19 1.7 23.3 14.5 47 5 49 305 -19.2 0 -19 -19.5 12/18/2005 21:50:00 19.8 1.6 23.3 16.1 19.6 1.7 23.7 15.3 46 5 48 305 -19.3 0 -19.2 -19.5 12/18/2005 22:00:00 18.9 1.7 22.6 14.5 18.6 1.7 22.1 14.1 45 5 39 305 -19.2 0 -19 -19.5 12/18/2005 22:10:00 18.9 1.6 22.1 14.5 18.6 1.7 22.9 14.1 46 5 39 305 -19.2 0 -19 -19.3 12/18/2005 22:20:00 19.5 1.5 22.9 15.6 19.2 1.5 22.6 14.5 44 5 48 305 -19.2 0 -19 -19.3 12/18/2005 22:30:00 18.4 2 22.9 13.3 18.2 2.1 23.7 14.1 44 5 43 305 -19.2 0 -19 -19.3 12/18/2005 22:40:00 17.3 1.5 21.4 13.7 17 1.5 21.4 13.3 42 6 39 305 -19.2 0 -19 -19.3 12/18/2005 22:50:00 17.6 1.5 21 13.7 17.3 1.5 21.4 13.7 44 5 42 305 -19.2 0 -19 -19.3 12/18/2005 23:00:00 17.3 1.7 21.4 12.6 17.1 1.8 21.4 13 42 5 40 305 -19.2 0 -19 -19.3 12/18/2005 23:10:00 17.4 1.6 21.4 13 17.1 1.7 21 13.3 40 6 43 305 -19.2 0 -19 -19.3 12/18/2005 23:20:00 17.7 1.7 21.4 13.7 17.6 1.7 21.4 13.7 42 5 37 305 -19.1 0 -19 -19.2 12/18/2005 23:30:00 18.6 1.8 22.9 14.5 18.4 1.8 22.9 13.7 42 5 44 305 -19.1 0 -19 -19.2 12/18/2005 23:40:00 17.8 1.6 21.4 12.6 17.7 1.7 22.1 13 40 5 48 305 -19 0.1 -18.8 -19 12/18/2005 23:50:00 17.8 1.7 22.1 14.1 17.5 1.7 22.6 13.7 41 5 31 305 -18.9 0 -18.8 -19 12/19/2005 00:00:00 16.6 1.7 20.6 12.6 16.4 1.7 21 11.8 37 6 30 305 -18.8 0 -18.4 -19 12/19/2005 00:10:00 17.4 1.7 21 13 17 1.6 21 13.3 38 5 37 305 -18.8 0 -18.6 -19 12/19/2005 00:20:00 17.1 1.5 20.6 13.3 16.7 1.5 21 13.3 36 6 31 305 -18.8 0 -18.6 -19 12/19/2005 00:30:00 16.7 1.9 22.9 12.6 16.4 1.9 22.6 12.2 37 6 34 305 -18.7 0 -18.4 -19 12/19/2005 00:40:00 17.1 1.7 20.6 13 16.8 1.7 21 12.6 40 6 42 305 -18.6 0 -18.4 -18.8 12/19/2005 00:50:00 16 1.6 20.6 12.2 15.8 1.7 20.2 11.8 43 6 41 305 -18.6 0 -18.4 -18.8 12/19/2005 01:00:00 17.9 1.8 21.8 12.6 17.6 1.7 21.4 12.6 42 6 40 305 -18.7 0 -18.4 -19 12/19/2005 01:10:00 18.6 1.8 22.6 14.1 18.4 1.8 22.1 13.7 41 6 44 305 -18.7 0 -18.4 -18.8 12/19/2005 01:20:00 19.6 1.5 22.9 14.9 19.5 1.7 22.9 14.9 43 5 43 305 -18.7 0 -18.4 -18.8 12/19/2005 01:30:00 19.5 2.2 24.4 14.1 19.1 2.2 24 13.7 45 5 46 305 -18.7 0 -18.4 -19 12/19/2005 01:40:00 19 2 23.7 13.7 18.8 2.1 23.3 13.3 43 5 44 305 -18.6 0 -18.4 -18.8 12/19/2005 01:50:00 19.7 1.8 24 14.9 19.3 1.9 23.7 14.9 43 5 41 305 -18.6 0 -18.4 -18.8 12/19/2005 02:00:00 18.8 1.7 22.9 14.5 18.6 1.7 22.9 13.7 46 5 48 305 -18.5 0 -18.2 -18.8 12/19/2005 02:10:00 18.6 1.7 22.6 14.1 18.5 1.7 23.3 14.1 44 5 46 305 -18.4 0 -18.2 -18.4 12/19/2005 02:20:00 17.2 1.3 21 13 17 1.4 21 13 44 5 40 305 -18.3 0 -18.2 -18.4 12/19/2005 02:30:00 19.4 2.1 23.3 14.5 19.2 2.1 23.3 14.1 43 5 41 305 -18.4 0 -18.2 -18.4 12/19/2005 02:40:00 20 1.7 24.4 14.5 19.7 1.8 24 13.3 45 5 41 305 -18.5 0 -18.2 -18.4 12/19/2005 02:50:00 18.4 1.7 22.6 13.3 18.1 1.7 22.9 13.7 43 6 51 305 -18.5 0 -18.2 -18.4 12/19/2005 03:00:00 19.4 1.9 24 14.9 19.2 1.8 24 14.1 44 6 51 305 -18.5 0 -18.4 -18.6 12/19/2005 03:10:00 18.8 1.8 22.6 14.1 18.5 1.9 22.6 14.1 45 5 39 305 -18.5 0 -18.4 -18.6 12/19/2005 03:20:00 17.3 2 21.4 11.8 17.2 2.1 21.8 12.6 45 5 44 305 -18.5 0 -18.4 -18.6 12/19/2005 03:30:00 18.4 1.5 21.8 14.5 18.4 1.6 21.8 13.7 47 6 39 305 -18.5 0 -18.2 -18.8 12/19/2005 03:40:00 16.4 1.5 20.2 12.6 16.2 1.5 19.5 13 47 5 44 305 -18.6 0 -18.4 -18.8 12/19/2005 03:50:00 17.5 1.3 20.6 13 17.3 1.5 20.2 12.6 48 4 57 305 -18.6 0 -18.4 -18.8 12/19/2005 04:00:00 17.5 1.7 23.3 13.7 17.3 1.7 22.6 14.1 46 6 33 305 -18.5 0 -18.2 -18.6 12/19/2005 04:10:00 17.4 1.6 21 13.3 17.2 1.6 21.4 13.3 45 5 46 305 -18.4 0 -17.9 -18.4 12/19/2005 04:20:00 16.7 1.8 21.4 13.3 16.5 1.9 21 12.2 43 6 38 305 -18.3 0 -18.1 -18.4 12/19/2005 04:30:00 17.7 1.5 21 13.3 17.6 1.6 21 13 39 5 37 305 -18.3 0 -18.1 -18.4 12/19/2005 04:40:00 17.8 2.2 22.9 13.3 17.7 2.2 22.6 13 42 6 43 305 -18.2 0 -18.1 -18.4 12/19/2005 04:50:00 17.8 1.4 21.4 13.7 17.5 1.5 21.8 13.7 42 6 45 305 -18.1 0 -18.1 -18.2 12/19/2005 05:00:00 19.9 1.9 24.8 14.9 19.5 2.1 24.4 13.7 38 5 38 305 -18.1 0.1 -18.1 -18.4 12/19/2005 05:10:00 19 2.3 24 12.6 18.8 2.2 24.4 13 41 6 38 305 -18.2 0 -18.1 -18.4 12/19/2005 05:20:00 19.4 1.8 23.7 14.9 19 2 23.7 14.5 40 6 41 305 -18.2 0 -18.1 -18.4 12/19/2005 05:30:00 19.8 1.9 23.7 14.1 19.5 1.9 23.3 14.9 43 6 43 305 -18.3 0.1 -18.1 -18.4 12/19/2005 05:40:00 19.5 2 23.7 13.7 19.2 1.9 24 14.9 42 5 48 305 -18.3 0 -18.1 -18.4 12/19/2005 05:50:00 18.8 2.1 23.3 13.3 18.5 2 22.9 12.6 40 6 37 305 -18.2 0.1 -18.1 -18.4 12/19/2005 06:00:00 18.3 2 22.6 13 18 1.9 22.1 13 42 5 41 305 -18.2 0.1 -18.1 -18.4 12/19/2005 06:10:00 18.3 1.7 22.9 13.7 18.1 1.7 23.3 13.3 39 6 38 305 -18.1 0 -18.1 -18.4 12/19/2005 06:20:00 20.1 1.8 24.4 14.5 19.9 1.9 23.7 13.3 42 6 35 305 -18.1 0 -18.1 -18.4 12/19/2005 06:30:00 19.4 1.5 22.9 13 19.2 1.7 22.9 13.3 44 5 48 305 -18.1 0 -18.1 -18.4 12/19/2005 06:40:00 19.1 2 23.3 14.9 18.8 2.2 23.7 14.1 41 6 47 305 -18.2 0 -18.1 -18.4 12/19/2005 06:50:00 18.5 1.8 22.6 13.3 18.4 1.9 22.9 13.7 40 5 40 305 -18.2 0 -18.1 -18.4 12/19/2005 07:00:00 19.2 1.7 22.6 14.5 18.9 1.7 22.6 14.1 38 5 36 305 -18.4 0 -18.2 -18.4 12/19/2005 07:10:00 17.6 1.9 22.1 13.3 17.5 1.9 22.6 13.3 39 6 35 305 -18.3 0.1 -18.1 -18.4 12/19/2005 07:20:00 18 2 24 13.7 17.7 2 23.7 13.7 40 5 37 305 -18.2 0 -18.1 -18.4 12/19/2005 07:30:00 18.7 2 22.9 13.3 18.5 2.1 22.9 12.6 45 5 38 305 -18.4 0 -18.1 -18.4 12/19/2005 07:40:00 18 1.9 22.6 13 17.7 1.8 21.8 12.6 41 6 43 305 -18.3 0 -18.1 -18.4 12/19/2005 07:50:00 20.3 1.7 24.4 15.6 20 1.7 24.8 15.3 41 5 40 305 -18.4 0 -18.2 -18.4 12/19/2005 08:00:00 18.4 1.7 22.1 13 18.2 1.7 22.6 13.7 43 5 43 305 -18.5 0 -18.2 -18.4 12/19/2005 08:10:00 18.7 2.1 23.7 13.7 18.5 2.1 23.7 14.1 42 5 52 305 -18.3 0 -18.1 -18.4 12/19/2005 08:20:00 18.5 1.7 22.1 13.3 18.4 1.7 23.3 13.7 43 5 44 305 -18.3 0 -18.1 -18.4 12/19/2005 08:30:00 19.7 1.7 23.7 14.1 19.4 1.7 24 14.9 39 6 36 305 -18.3 0 -18.1 -18.4 12/19/2005 08:40:00 19 2.1 25.2 14.1 18.8 2.1 24.8 13.7 43 5 45 305 -18.4 0 -18.2 -18.4 12/19/2005 08:50:00 18.5 1.9 22.9 13.7 18.1 1.8 22.9 13 39 6 34 305 -18.4 0 -18.2 -18.4 12/19/2005 09:00:00 19.9 1.6 23.3 16.1 19.7 1.5 23.3 15.6 41 5 40 305 -18.4 0 -18.2 -18.4 12/19/2005 09:10:00 18.5 1.8 22.1 13.3 18.2 1.9 22.6 12.6 42 5 38 305 -18.4 0 -18.2 -18.4 12/19/2005 09:20:00 17.6 2.2 21.8 12.6 17.4 2.2 22.6 12.6 43 5 39 305 -18.4 0 -18.1 -18.4 12/19/2005 09:30:00 18 1.8 22.1 13 17.8 1.8 22.6 13.3 42 5 40 305 -18.3 0 -18.1 -18.4 12/19/2005 09:40:00 18.6 1.7 22.1 14.1 18.4 1.6 22.1 14.1 37 4 33 305 -18.3 0 -18.1 -18.4 12/19/2005 09:50:00 17.2 1.8 21 13 16.9 1.8 21 13 36 5 32 305 -18.2 0 -18.1 -18.4 12/19/2005 10:00:00 18.2 1.7 22.1 13.7 17.9 1.7 22.6 13.7 37 5 40 305 -18.2 0 -18.1 -18.4 12/19/2005 10:10:00 18.7 1.5 21.8 14.5 18.4 1.6 22.1 13.3 37 5 38 305 -18.3 0 -18.1 -18.4 12/19/2005 10:20:00 18.4 1.4 22.1 14.5 18 1.5 22.1 14.5 37 6 32 305 -18.3 0 -18.1 -18.4 12/19/2005 10:30:00 17.8 1.9 22.6 13 17.8 1.8 22.6 13.3 38 5 35 305 -18.3 0 -18.1 -18.4 12/19/2005 10:40:00 16.8 2.1 22.9 11.8 16.6 2 22.9 11.8 41 6 37 305 -18.2 0 -18.1 -18.4 12/19/2005 10:50:00 16.9 1.7 21.4 12.6 16.6 1.7 21.4 12.2 36 5 34 305 -18.3 0 -18.1 -18.4 12/19/2005 11:00:00 18.4 1.5 22.6 13.3 18.2 1.5 22.6 13.7 37 6 20 305 -18.4 0 -18.2 -18.4 12/19/2005 11:10:00 16.7 1.9 21.4 13 16.6 1.9 21 12.6 42 6 37 305 -18.4 0 -18.2 -18.4 12/19/2005 11:20:00 18.2 1.8 22.6 13 17.9 1.9 22.6 13.3 42 6 41 305 -18.4 0 -18.2 -18.4 12/19/2005 11:30:00 17.7 2 22.9 13.3 17.4 2 23.7 13.3 40 5 35 305 -18.5 0 -18.2 -18.4 12/19/2005 11:40:00 18.2 1.4 21.8 13.7 17.9 1.6 21.4 13.3 36 4 36 305 -18.5 0 -18.2 -18.4 12/19/2005 11:50:00 18.4 1.6 22.6 14.1 18.2 1.6 22.6 14.9 40 5 43 305 -18.4 0 -18.2 -18.4 12/19/2005 12:00:00 16.1 1.5 20.2 12.6 16 1.6 21 12.2 39 6 32 305 -18.3 0 -18.1 -18.4 12/19/2005 12:10:00 17 1.9 21.8 12.2 16.7 2 21.4 12.6 39 6 39 305 -18.2 0 -18.1 -18.4 12/19/2005 12:20:00 17.8 2.1 22.6 12.6 17.6 2.1 22.6 12.2 40 5 32 305 -18.1 0 -18.1 -18.4 12/19/2005 12:30:00 17.8 1.7 23.3 14.5 17.5 1.9 22.9 13.3 41 6 39 305 -18.2 0 -18.1 -18.4 12/19/2005 12:40:00 16.9 1.6 21 12.2 16.5 1.7 21.4 12.6 39 5 40 305 -18.1 0 -18.1 -18.4 12/19/2005 12:50:00 17 2.2 22.6 11.1 16.7 2.1 22.1 11.5 40 6 39 305 -18.1 0 -17.9 -18.4 12/19/2005 13:00:00 18.3 1.7 21.8 12.6 18.2 1.7 21.4 13.3 39 5 34 305 -18.1 0 -18.1 -18.4 12/19/2005 13:10:00 18.9 1.9 23.3 14.1 18.6 2 22.9 13.7 41 6 36 305 -18.1 0 -18.1 -18.4 12/19/2005 13:20:00 18.6 2.1 23.3 14.1 18.3 2.1 23.3 13.7 39 6 37 305 -18.1 0 -18.1 -18.2 12/19/2005 13:30:00 18.1 1.8 22.1 13 17.8 1.8 21.8 12.6 38 5 38 305 -18.2 0 -18.1 -18.4 12/19/2005 13:40:00 16.9 2.1 23.3 12.6 16.6 2.1 23.3 13 38 7 33 305 -18.1 0 -18.1 -18.4 12/19/2005 13:50:00 19.4 2 23.3 13 19 1.9 23.3 13 36 6 35 305 -18.4 0 -18.1 -18.4 12/19/2005 14:00:00 18.8 1.7 23.3 13.7 18.5 1.8 22.9 13.7 39 6 36 305 -18.4 0 -18.1 -18.4 12/19/2005 14:10:00 19.4 2.1 24 14.5 19.1 2.3 24.8 13.7 37 6 40 305 -18.4 0 -18.2 -18.6 12/19/2005 14:20:00 18.8 2.1 24 14.1 18.5 2.1 24 14.1 37 6 35 305 -18.5 0 -18.2 -18.6 12/19/2005 14:30:00 18.2 1.7 22.9 14.5 18 1.7 22.6 13.3 37 6 32 305 -18.6 0 -18.4 -18.6 12/19/2005 14:40:00 18.4 1.9 22.1 12.6 18.1 1.8 22.6 13 37 5 32 305 -18.6 0 -18.4 -18.6 12/19/2005 14:50:00 17.9 1.8 21.8 13.3 17.6 1.8 22.1 12.6 37 5 31 305 -18.6 0 -18.4 -18.6 12/19/2005 15:00:00 16.3 1.7 19.9 11.5 16.1 1.7 19.9 11.8 38 6 38 305 -18.5 0 -18.4 -18.6 12/19/2005 15:10:00 17.5 2 22.6 11.8 17 2 22.9 12.2 40 6 38 305 -18.6 0 -18.4 -18.6 12/19/2005 15:20:00 18.3 1.9 22.6 13.3 18 1.8 22.6 13.7 36 5 38 305 -18.6 0 -18.4 -18.8 12/19/2005 15:30:00 19.2 1.7 23.7 15.3 18.8 1.8 22.9 14.1 37 5 39 305 -18.6 0 -18.4 -18.6 12/19/2005 15:40:00 17.8 1.7 21.8 13.3 17.5 1.7 22.1 13.7 38 5 38 305 -18.6 0 -18.4 -18.6 12/19/2005 15:50:00 16.3 2.2 21.8 11.1 16 2.2 21 11.5 34 6 32 305 -18.5 0 -18.2 -18.4 12/19/2005 16:00:00 17.1 1.8 21.4 12.2 16.8 2 21.8 12.6 35 5 36 305 -18.5 0 -18.1 -18.4 12/19/2005 16:10:00 17.2 2 22.1 12.6 16.7 2 22.1 12.2 32 5 34 305 -18.5 0 -18.4 -18.4 12/19/2005 16:20:00 18.4 1.7 22.6 14.1 17.9 1.8 22.6 13.3 34 6 24 305 -18.5 0 -18.4 -18.6 12/19/2005 16:30:00 18 1.7 21.8 12.6 17.6 1.7 21.8 13 33 5 32 305 -18.6 0 -18.4 -18.6 12/19/2005 16:40:00 18.2 2.2 21.8 12.6 17.7 2.2 21.8 12.2 34 5 38 305 -18.5 0 -18.4 -18.6 12/19/2005 16:50:00 17.2 2.1 22.1 12.6 16.9 2 21.8 12.6 32 5 24 305 -18.5 0 -18.2 -18.4 12/19/2005 17:00:00 17.5 1.5 21 13.7 17 1.5 21.4 13.3 31 5 32 305 -18.5 0 -18.2 -18.4 12/19/2005 17:10:00 16.7 1.9 21 12.6 16.3 1.7 21 12.6 32 6 29 305 -18.3 0 -18.1 -18.4 12/19/2005 17:20:00 16.3 2.3 22.1 11.1 16.2 2.3 22.1 11.8 34 6 32 305 -18.1 0 -18.1 -18.4 12/19/2005 17:30:00 16.5 1.8 21 12.2 16.3 1.9 21 12.2 33 7 40 305 -18.1 0 -18.1 -18.4 12/19/2005 17:40:00 15.9 1.7 20.2 11.8 15.5 1.6 20.2 11.8 29 6 26 305 -18.1 0 -18.1 -18.2 12/19/2005 17:50:00 17.5 1.8 21.8 11.1 17.1 1.7 22.6 11.5 30 6 29 305 -18.1 0 -18.1 -18.4 12/19/2005 18:00:00 16.4 2.1 21.8 11.5 16 2.1 21.8 11.5 30 7 22 305 -18.1 0 -18.1 -18.4 12/19/2005 18:10:00 17.9 2 21.4 12.6 17.5 2 22.1 12.2 30 6 35 305 -18.3 0.1 -18.1 -18.4 12/19/2005 18:20:00 17.5 1.9 21.4 12.2 17.1 1.7 21.4 12.2 30 6 30 305 -18.4 0 -18.2 -18.4 12/19/2005 18:30:00 17.3 2.4 22.1 11.5 16.9 2.3 21.8 11.5 33 5 34 305 -18.2 0 -18.1 -18.4 12/19/2005 18:40:00 18.3 1.8 22.6 14.1 17.7 1.8 22.1 13.7 33 5 31 305 -18.1 0 -18.1 -18.4 12/19/2005 18:50:00 17.6 1.8 22.1 13 17.1 1.7 21 13 31 5 28 305 -18.2 0 -18.1 -18.4 12/19/2005 19:00:00 18.3 2.1 22.1 13 17.8 2 22.1 12.2 31 6 36 305 -18.1 0 -18.1 -18.4 12/19/2005 19:10:00 17.8 1.9 22.1 13 17.4 1.7 21.8 13.3 31 6 27 305 -18.2 0 -18.1 -18.4 12/19/2005 19:20:00 17.6 1.7 22.9 13.7 17.2 1.7 22.6 13.3 31 6 29 305 -18.1 0 -18.1 -18.4 12/19/2005 19:30:00 18.4 2.3 23.7 13.7 17.8 2.3 23.7 12.6 31 6 30 305 -18.2 0 -18.1 -18.4 12/19/2005 19:40:00 18.7 2.3 23.3 13.3 18.2 2.3 23.7 12.6 29 6 34 305 -18.2 0 -18.1 -18.4 12/19/2005 19:50:00 18.6 1.9 22.9 13.3 18.1 2.1 22.6 13.3 32 6 33 305 -18.1 0 -18.1 -18.2 12/19/2005 20:00:00 19.3 1.8 22.9 13.7 18.6 1.8 22.6 13.7 33 6 34 305 -18.1 0 -17.9 -18.2 12/19/2005 20:10:00 18.9 2 23.3 13.3 18.6 1.9 24 13.7 32 5 29 305 -18 0 -17.9 -18.1 12/19/2005 20:20:00 19.7 2 25.2 14.1 19.1 2 24.4 14.1 29 5 26 305 -18 0 -17.7 -18.1 12/19/2005 20:30:00 18.8 2.1 23.7 13.3 18.4 1.9 22.9 13.7 25 6 30 305 -18 0 -17.7 -18.1 12/19/2005 20:40:00 19.7 2.4 24.4 13 19.3 2.3 24.4 12.6 29 6 26 305 -17.8 0.1 -17.5 -18.1 12/19/2005 20:50:00 18.4 2.2 23.7 13 17.8 2.1 22.9 12.6 28 7 33 305 -17.5 0.1 -17.3 -17.9 12/19/2005 21:00:00 18.8 2.1 23.7 13.7 18.4 2 24 13.3 29 6 27 305 -17.6 0.1 -17.3 -17.9 12/19/2005 21:10:00 18.9 2.1 23.3 13.7 18.5 2 22.9 13.3 28 6 40 305 -17.5 0 -17.3 -17.7 12/19/2005 21:20:00 18.4 2.3 24 11.5 17.9 2.3 24 11.8 28 6 33 305 -17.5 0 -17.3 -17.7 12/19/2005 21:30:00 20 2.5 25.2 14.1 19.5 2.5 24.8 13 28 5 27 305 -17.6 0.1 -17.3 -17.9 12/19/2005 21:40:00 18.8 2.3 24.8 13.7 18.4 2.2 23.7 13 30 7 35 305 -17.5 0 -17.1 -17.7 12/19/2005 21:50:00 19.7 2.6 25.2 13.7 19.1 2.6 24.4 14.5 29 5 30 305 -17.7 0.1 -17.5 -18.1 12/19/2005 22:00:00 19.3 2.4 23.7 14.1 19 2.4 24.4 13.3 31 7 33 305 -17.6 0 -17.5 -17.9 12/19/2005 22:10:00 19.1 2.8 25.2 13 18.7 2.6 24.8 11.8 32 6 31 305 -17.5 0 -17.3 -17.9 12/19/2005 22:20:00 19.1 2.4 24.8 13.7 18.8 2.4 24.8 13 35 6 36 305 -17.5 0 -17.3 -17.7 12/19/2005 22:30:00 20.7 2.3 26 15.3 20.3 2.4 26 13.3 35 6 32 305 -17.6 0.1 -17.3 -17.7 12/19/2005 22:40:00 20.5 2.3 25.2 14.1 19.8 2.3 25.6 13.7 30 6 27 305 -17.5 0 -17.3 -17.7 12/19/2005 22:50:00 19.2 2.6 25.2 13.7 18.8 2.6 24.8 13.3 33 7 37 305 -17.5 0.1 -17.1 -17.7 12/19/2005 23:00:00 19.3 2.5 26 14.1 18.7 2.4 24.8 13.3 31 7 25 305 -17.4 0.1 -16.9 -17.5 12/19/2005 23:10:00 20.7 2.5 26.3 13.7 20.3 2.3 26.3 14.5 33 6 27 305 -17.3 0.1 -16.9 -17.5 12/19/2005 23:20:00 20 2.4 25.6 14.9 19.6 2.2 25.2 15.3 31 6 27 305 -17.3 0.1 -16.9 -17.5 12/19/2005 23:30:00 20.7 2.4 26.8 14.9 20.1 2.4 25.2 14.5 31 6 32 305 -17.2 0.1 -16.9 -17.5 12/19/2005 23:40:00 21.3 2 26.8 16.1 20.8 2.1 26 15.6 32 5 32 305 -17.2 0.1 -16.9 -17.3 12/19/2005 23:50:00 18.9 2.3 25.6 14.1 18.6 2.2 24 13.3 31 6 27 305 -17.1 0 -16.9 -17.3 12/20/2005 00:00:00 21.3 1.9 25.6 16.1 20.8 2 25.2 14.9 32 6 29 305 -17.1 0 -16.9 -17.3 12/20/2005 00:10:00 18.6 2.4 25.2 13.3 18.3 2.4 24.4 12.6 33 6 32 305 -17 0 -16.9 -17.3 12/20/2005 00:20:00 21.3 2.3 26.3 16.1 20.8 2.3 26.3 14.9 36 5 32 305 -17.1 0 -16.9 -17.3 12/20/2005 00:30:00 19.8 2.7 25.6 13.3 19.3 2.7 25.2 13.7 36 7 50 305 -17 0 -16.9 -17.1 12/20/2005 00:40:00 19 2.4 24.8 14.5 18.7 2.4 24.8 13.3 36 6 44 305 -17.1 0 -16.9 -17.1 12/20/2005 00:50:00 19.5 2.2 24.4 14.1 19.1 2.2 23.7 14.1 37 6 33 305 -17.1 0 -16.9 -17.3 12/20/2005 01:00:00 16 1.9 21.8 12.2 15.8 1.9 21 11.8 37 7 33 305 -17.1 0 -16.9 -17.3 12/20/2005 01:10:00 16.5 2 23.7 12.6 16.3 1.9 23.3 11.8 35 6 50 305 -17 0 -16.6 -17.1 12/20/2005 01:20:00 17.9 2.3 22.9 12.6 17.6 2.3 23.3 12.6 35 7 42 305 -17 0 -16.9 -17.3 12/20/2005 01:30:00 18.3 2.2 24 12.6 17.9 2.2 23.3 11.8 36 6 33 305 -17.1 0 -16.9 -17.3 12/20/2005 01:40:00 18.3 2.5 24 12.2 17.9 2.5 24.8 12.2 35 7 41 305 -17.1 0 -16.9 -17.3 12/20/2005 01:50:00 17.7 2.1 22.9 12.6 17.3 2.1 22.9 12.2 37 7 46 305 -17.1 0 -16.9 -17.1 12/20/2005 02:00:00 19.5 2.5 27.5 14.1 19.1 2.5 26.3 13.7 35 7 34 305 -17 0 -16.6 -17.3 12/20/2005 02:10:00 17.9 2 22.6 13.3 17.6 2 22.6 12.6 38 6 34 305 -17 0 -16.9 -17.1 12/20/2005 02:20:00 17.1 2 21.4 11.8 16.8 2 22.1 11.8 38 6 31 305 -17.1 0 -16.9 -17.3 12/20/2005 02:30:00 17.5 2.5 23.7 11.8 17.2 2.6 22.9 12.2 37 7 30 305 -17.2 0.1 -16.9 -17.5 12/20/2005 02:40:00 19.3 1.8 24 14.1 19 1.7 23.7 14.1 37 7 35 305 -17.3 0.1 -16.9 -17.5 12/20/2005 02:50:00 18.1 2.1 23.7 13 17.8 2.1 23.3 12.6 38 6 35 305 -17.3 0.1 -16.9 -17.5 12/20/2005 03:00:00 17 1.8 20.6 13 16.7 1.9 21 12.2 38 6 41 305 -17.2 0.1 -16.9 -17.5 12/20/2005 03:10:00 17.3 2.5 23.3 12.2 17.1 2.5 24.4 11.5 36 6 37 305 -17.2 0.1 -16.9 -17.5 12/20/2005 03:20:00 19.7 2.1 23.7 13.3 19.3 2.2 24 13.7 37 6 29 305 -17.3 0.1 -16.9 -17.5 12/20/2005 03:30:00 18.2 2.3 23.3 13.3 17.8 2.4 22.6 13 38 7 46 305 -17.2 0.1 -16.9 -17.5 12/20/2005 03:40:00 19.7 2.4 25.2 14.1 19.3 2.4 25.2 13.7 39 6 42 305 -17.3 0.1 -16.9 -17.5 12/20/2005 03:50:00 18.9 1.9 24.8 12.6 18.8 2 24 13 40 6 43 305 -17.2 0.1 -16.9 -17.5 12/20/2005 04:00:00 19.1 2.1 24.8 14.1 18.8 2.1 24 14.9 40 6 38 305 -17.2 0.1 -16.9 -17.3 12/20/2005 04:10:00 17.4 1.9 21.8 13 17 1.8 21.8 12.2 40 6 35 305 -17.2 0 -16.9 -17.3 12/20/2005 04:20:00 19.3 1.9 25.6 14.9 19 2 25.2 14.5 38 6 39 305 -17.2 0 -16.9 -17.3 12/20/2005 04:30:00 17.5 2.1 23.3 13 17.2 2.3 23.3 12.6 40 6 50 305 -17.2 0 -16.9 -17.3 12/20/2005 04:40:00 18.7 2.2 24.4 13.7 18.4 2.2 23.7 13.3 39 6 36 305 -17.1 0 -16.9 -17.3 12/20/2005 04:50:00 19.2 2.5 24.8 13.7 18.9 2.4 24.8 13 40 6 32 305 -17.2 0 -16.9 -17.3 12/20/2005 05:00:00 19.2 1.7 23.7 15.6 18.9 1.7 24 15.3 40 7 40 305 -17.2 0 -16.9 -17.3 12/20/2005 05:10:00 19 2 25.6 14.5 18.5 2 24 14.1 38 6 45 305 -17.2 0 -16.9 -17.3 12/20/2005 05:20:00 17.8 2.3 22.9 13 17.6 2.3 23.3 12.6 38 6 41 305 -17.2 0.1 -16.9 -17.3 12/20/2005 05:30:00 17.9 2 22.9 13.3 17.4 1.9 23.3 13 38 7 35 305 -17.2 0 -16.9 -17.3 12/20/2005 05:40:00 17.5 2.1 22.9 13.3 17.2 2 22.1 13 39 6 34 305 -17.1 0 -16.9 -17.3 12/20/2005 05:50:00 18 2.2 22.9 12.6 18 2.1 22.6 12.6 41 6 39 305 -17.1 0 -16.9 -17.3 12/20/2005 06:00:00 19.7 1.9 23.3 13.7 19.5 1.8 23.3 14.1 38 5 35 305 -17.1 0 -16.9 -17.3 12/20/2005 06:10:00 18.4 1.9 23.3 14.1 18 1.8 22.9 14.1 38 6 29 305 -17.1 0 -16.9 -17.3 12/20/2005 06:20:00 18.3 2.4 23.3 12.6 18 2.4 22.6 12.6 35 6 30 305 -17 0 -16.9 -17.1 12/20/2005 06:30:00 17.8 1.9 22.6 12.6 17.4 1.9 22.1 11.8 35 5 35 305 -17 0 -16.9 -17.1 12/20/2005 06:40:00 17.5 2 22.1 12.6 17.2 2 21.8 12.6 38 6 37 305 -16.9 0 -16.6 -17.1 12/20/2005 06:50:00 18.6 1.7 22.9 13.7 18.5 1.7 22.9 14.5 40 5 29 305 -16.9 0 -16.6 -17.1 12/20/2005 07:00:00 17.6 2.1 22.1 12.2 17.2 2.2 22.1 11.8 41 7 46 305 -16.9 0 -16.6 -16.9 12/20/2005 07:10:00 18 2.2 23.7 12.6 18 2.3 23.7 12.2 42 6 43 305 -16.9 0 -16.6 -16.9 12/20/2005 07:20:00 19 1.9 24 14.9 18.8 2 23.7 13.7 42 5 29 305 -16.9 0 -16.6 -16.9 12/20/2005 07:30:00 19.1 2.3 24 12.2 18.7 2.4 24 12.6 41 6 39 305 -16.9 0 -16.6 -16.9 12/20/2005 07:40:00 18.6 2.1 23.3 13.7 18.4 2.1 22.9 13.3 42 6 43 305 -16.9 0 -16.6 -16.9 12/20/2005 07:50:00 18.8 1.7 22.9 13.3 18.6 1.7 23.3 14.1 44 6 40 305 -16.9 0 -16.6 -16.9 12/20/2005 08:00:00 18.2 2 24.4 13.7 18 2.1 23.3 13 42 6 38 305 -16.9 0 -16.6 -16.9 12/20/2005 08:10:00 19.5 2.3 25.2 13.7 19.2 2.3 24 13 39 6 25 305 -16.9 0 -16.6 -16.9 12/20/2005 08:20:00 19.6 2.1 24 15.3 19.3 2.1 24.8 14.1 40 6 38 305 -16.9 0 -16.6 -16.9 12/20/2005 08:30:00 20.3 1.8 24.4 14.9 20 1.8 24 15.3 38 6 37 305 -16.9 0 -16.6 -16.9 12/20/2005 08:40:00 19.2 2.2 24 13 18.9 2.3 24.8 13.7 41 6 48 305 -16.9 0 -16.6 -16.9 12/20/2005 08:50:00 18.7 2 24 13.7 18.6 2.1 22.9 14.1 44 6 45 305 -16.9 0 -16.6 -16.9 12/20/2005 09:00:00 19.8 1.8 25.2 14.1 19.5 1.9 24.4 14.1 43 6 50 305 -16.9 0 -16.4 -16.9 12/20/2005 09:10:00 19.7 1.8 24.8 14.1 19.7 1.8 24 14.5 44 6 53 305 -16.9 0 -16.6 -16.9 12/20/2005 09:20:00 19.4 1.9 24.4 14.9 19.1 2 24.8 14.1 41 6 42 305 -16.9 0 -16.6 -16.9 12/20/2005 09:30:00 17.3 2.5 22.1 12.6 17.2 2.6 22.6 12.2 44 6 39 305 -16.8 0 -16.4 -16.9 12/20/2005 09:40:00 18.7 2.1 23.3 13.7 18.6 2.1 23.7 14.1 41 6 35 305 -16.8 0.1 -16.4 -16.9 12/20/2005 09:50:00 19.5 1.7 23.7 14.9 19.3 1.8 24 14.1 42 6 39 305 -16.9 0 -16.4 -16.9 12/20/2005 10:00:00 18.9 2.4 24 13 19 2.4 24.8 12.6 43 5 47 305 -16.8 0.1 -16.4 -16.9 12/20/2005 10:10:00 18.7 2 23.7 13.7 18.7 2 23.7 13 42 6 45 305 -16.8 0.1 -16.4 -16.9 12/20/2005 10:20:00 20 1.8 24 15.3 19.9 1.7 23.7 14.9 41 6 35 305 -16.8 0 -16.4 -16.9 12/20/2005 10:30:00 19.8 2.2 24 14.5 19.8 2.3 25.6 14.5 44 6 51 305 -16.8 0 -16.4 -16.9 12/20/2005 10:40:00 21.2 1.9 25.2 16.1 21.1 1.8 25.6 16.8 44 6 45 305 -16.9 0 -16.6 -16.9 12/20/2005 10:50:00 21.1 1.8 25.2 16.1 21.1 1.9 25.2 16.4 44 5 42 305 -16.9 0 -16.6 -16.9 12/20/2005 11:00:00 20.4 1.9 25.2 15.3 20.3 2 25.2 15.3 43 5 39 305 -16.7 0.1 -16.4 -16.9 12/20/2005 11:10:00 20 2.1 24.4 14.9 19.9 2.1 24 14.5 40 5 42 305 -16.6 0.1 -16.4 -16.9 12/20/2005 11:20:00 19.9 1.7 24 15.3 19.8 1.7 23.3 14.9 41 5 38 305 -16.5 0.1 -16.2 -16.7 12/20/2005 11:30:00 19.2 2.4 23.7 13 19 2.5 23.7 13.3 42 6 40 305 -16.4 0 -16 -16.6 12/20/2005 11:40:00 19.7 1.7 22.9 14.9 19.5 1.7 23.3 13.7 43 6 43 305 -16.4 0.1 -16 -16.6 12/20/2005 11:50:00 19.4 1.8 24 14.1 19.3 1.7 24.4 14.5 42 5 36 305 -16.3 0 -16 -16.6 12/20/2005 12:00:00 18.5 1.9 22.9 14.1 18.4 1.8 22.9 14.1 44 6 40 305 -16.3 0.1 -15.8 -16.6 12/20/2005 12:10:00 20.1 1.7 23.7 14.5 20 1.8 24 14.9 46 5 46 305 -16.3 0 -16 -16.6 12/20/2005 12:20:00 20.7 1.7 24.4 16.1 20.7 1.7 24.4 16.8 46 5 42 305 -16.3 0.1 -15.8 -16.4 12/20/2005 12:30:00 19.6 1.9 23.3 14.5 19.4 1.9 22.9 14.5 46 5 47 305 -16.3 0 -16 -16.6 12/20/2005 12:40:00 18.4 1.7 22.6 14.5 18.3 1.7 22.9 14.5 45 6 48 305 -16.3 0.1 -16 -16.6 12/20/2005 12:50:00 17.8 1.5 21.4 14.1 17.8 1.5 22.1 14.1 44 5 39 305 -16.3 0.1 -15.8 -16.4 12/20/2005 13:00:00 17.3 1.6 21.4 13.3 17.4 1.7 21.8 13.3 45 5 46 305 -16.2 0.1 -15.8 -16.4 12/20/2005 13:10:00 17.4 1.7 21 12.2 17.5 1.8 21.4 13 45 5 47 305 -16.2 0.2 -15.8 -16.4 12/20/2005 13:20:00 16.9 2.1 21.4 12.6 16.8 2.1 21 11.8 40 6 35 305 -16.2 0.1 -15.8 -16.4 12/20/2005 13:30:00 18.4 1.5 21.8 14.9 18.5 1.5 22.1 14.5 37 5 40 305 -16.2 0.1 -15.8 -16.4 12/20/2005 13:40:00 17.5 1.7 21.4 12.2 17.4 1.7 22.1 12.2 38 5 28 305 -16.2 0.1 -15.8 -16.4 12/20/2005 13:50:00 18.4 2 22.9 11.1 18.2 1.9 21.8 11.8 36 6 36 305 -16.2 0.1 -15.8 -16.4 12/20/2005 14:00:00 19.1 1.7 23.3 13 18.8 1.7 22.6 13.7 37 5 34 305 -16.1 0.1 -15.8 -16.4 12/20/2005 14:10:00 18.9 1.7 22.9 14.9 18.7 1.7 23.3 14.5 36 5 31 305 -16.1 0.1 -15.8 -16.4 12/20/2005 14:20:00 19.3 1.7 23.3 14.1 19.1 1.7 24 14.1 39 5 37 305 -16.1 0.1 -15.8 -16.4 12/20/2005 14:30:00 18.7 1.9 23.7 13.3 18.5 1.9 23.3 13 38 6 32 305 -16.1 0.1 -15.8 -16.4 12/20/2005 14:40:00 19.2 2 23.7 14.1 19.1 2 24 14.1 38 5 34 305 -16.1 0 -15.6 -16.2 12/20/2005 14:50:00 19.5 1.9 24.4 14.5 19.2 2 24.4 14.5 40 6 35 305 -16.1 0 -15.6 -16.2 12/20/2005 15:00:00 18.2 2 22.1 13.3 17.9 2 22.9 13 40 5 38 305 -16 0 -15.6 -16.2 12/20/2005 15:10:00 17.8 1.8 22.1 13.3 17.5 1.7 22.6 13 40 6 45 305 -16.1 0 -15.6 -16.2 12/20/2005 15:20:00 15.7 1.5 19.5 11.5 15.4 1.7 19.5 11.1 42 6 45 305 -16.1 0.1 -15.6 -16.4 12/20/2005 15:30:00 16.1 1.9 21 12.6 16 1.9 21 11.8 41 6 40 305 -16.1 0 -15.6 -16.4 12/20/2005 15:40:00 17.2 1.8 21 12.2 16.9 1.8 21.4 11.8 39 6 36 305 -16 0.1 -15.6 -16.2 12/20/2005 15:50:00 15.7 1.7 19.5 11.5 15.5 1.7 19.5 11.5 39 6 39 305 -16 0.1 -15.6 -16.2 12/20/2005 16:00:00 15.9 2.1 21.8 11.5 15.7 2.1 21 11.1 37 6 41 305 -16 0 -15.6 -16.2 12/20/2005 16:10:00 18 1.8 23.3 13.3 17.6 1.8 22.1 13.3 35 6 44 305 -16 0.1 -15.6 -16.2 12/20/2005 16:20:00 16.9 2 21.4 12.2 16.5 2 21 11.5 34 6 35 305 -16.1 0.1 -15.6 -16.4 12/20/2005 16:30:00 17 1.7 22.1 12.6 16.6 1.7 21 11.8 33 5 36 305 -16.1 0.1 -15.8 -16.4 12/20/2005 16:40:00 18 1.7 21.8 13.3 17.6 1.7 21.4 13 34 5 33 305 -16.2 0.1 -15.8 -16.4 12/20/2005 16:50:00 16.6 1.8 21.4 13 16.4 1.7 21.4 12.2 34 6 37 305 -16.2 0.1 -15.8 -16.4 12/20/2005 17:00:00 17.4 1.9 22.1 13 17 1.9 21.8 12.2 36 6 30 305 -16.2 0.1 -15.8 -16.4 12/20/2005 17:10:00 17.2 1.9 22.1 13 16.9 2 21.8 13 36 5 35 305 -16.2 0.1 -15.8 -16.4 12/20/2005 17:20:00 16.7 1.7 21 12.6 16.4 1.7 21 12.2 33 6 30 305 -16.3 0.1 -16 -16.6 12/20/2005 17:30:00 18.2 2.3 22.9 12.6 17.8 2.2 22.1 12.2 34 6 34 305 -16.5 0.1 -16 -16.7 12/20/2005 17:40:00 17.6 1.7 22.6 11.8 17.4 1.7 22.6 12.6 37 6 32 305 -16.4 0.1 -16 -16.6 12/20/2005 17:50:00 17.5 2.4 22.9 11.5 17.2 2.3 22.9 12.6 35 6 35 305 -16.6 0.2 -16 -16.9 12/20/2005 18:00:00 18 1.7 21.8 13.3 17.6 1.7 21.4 13.7 35 6 41 305 -16.8 0.1 -16.4 -16.9 12/20/2005 18:10:00 18.9 2.1 23.3 13.7 18.3 2 23.3 12.2 34 6 32 305 -16.9 0 -16.6 -16.9 12/20/2005 18:20:00 19.9 1.7 23.7 13.7 19.3 1.7 23.3 14.5 32 6 32 305 -16.9 0 -16.6 -17.1 12/20/2005 18:30:00 19.7 1.8 23.7 14.5 19.2 1.8 23.7 14.1 33 5 30 305 -17 0 -16.9 -17.1 12/20/2005 18:40:00 19.5 1.7 23.3 14.5 19 1.7 22.6 14.5 35 5 43 305 -17.2 0 -16.9 -17.3 12/20/2005 18:50:00 19.8 2 24.4 14.9 19.4 2.1 24.8 14.1 34 6 34 305 -17.3 0.1 -16.9 -17.5 12/20/2005 19:00:00 18.5 2.1 24 13.3 18 2 24 14.1 34 6 33 305 -17.4 0 -16.9 -17.5 12/20/2005 19:10:00 18.2 1.8 22.9 13.7 17.8 1.7 22.9 14.1 33 6 29 305 -17.4 0 -16.9 -17.5 12/20/2005 19:20:00 19.3 2 24 14.1 18.7 1.9 22.9 13.7 32 5 31 305 -17.4 0 -17.1 -17.5 12/20/2005 19:30:00 17.5 1.8 22.1 13.3 17.3 1.7 23.3 13 33 6 24 305 -17.3 0.1 -16.9 -17.5 12/20/2005 19:40:00 18.4 2.2 23.7 13.3 18.1 2 22.9 13.3 32 6 28 305 -17.3 0.1 -16.9 -17.5 12/20/2005 19:50:00 19.4 2.5 24 14.1 18.9 2.5 24.4 13.3 34 6 39 305 -17.3 0.1 -16.9 -17.5 12/20/2005 20:00:00 19.2 2 23.7 14.5 18.7 1.9 23.3 14.9 34 6 40 305 -17.3 0 -16.9 -17.5 12/20/2005 20:10:00 19.7 2 24.4 14.1 19.2 2 24 13.7 36 6 29 305 -17.3 0.1 -16.9 -17.5 12/20/2005 20:20:00 18.6 2.4 24 13.7 18.2 2.4 23.3 13.3 38 6 33 305 -17.3 0.1 -16.9 -17.5 12/20/2005 20:30:00 18.8 1.9 22.9 13.7 18.5 1.9 23.3 14.1 36 6 39 305 -17.2 0 -16.9 -17.3 12/20/2005 20:40:00 18.5 2 22.6 13 18.2 2.1 22.9 13.3 39 5 31 305 -17.3 0.1 -16.9 -17.5 12/20/2005 20:50:00 17.9 1.9 22.9 13 17.6 1.9 22.9 13 38 6 33 305 -17.2 0 -16.9 -17.3 12/20/2005 21:00:00 17.5 2.3 22.9 11.8 17 2.2 22.1 11.8 32 6 32 305 -17.2 0.1 -16.9 -17.5 12/20/2005 21:10:00 17.6 2.1 22.9 13 17.2 2 22.6 12.6 34 6 35 305 -17.2 0.1 -16.9 -17.5 12/20/2005 21:20:00 18.5 1.7 22.1 14.5 18.1 1.6 21.8 14.5 34 6 34 305 -17.3 0 -16.9 -17.5 12/20/2005 21:30:00 18.2 2.2 23.7 12.2 17.9 2.3 22.6 11.1 34 6 33 305 -17.3 0.1 -16.9 -17.5 12/20/2005 21:40:00 17.8 2 23.3 13.3 17.6 2 22.9 13.3 36 6 38 305 -17.3 0.1 -16.9 -17.5 12/20/2005 21:50:00 17.5 1.7 22.1 13.3 17.1 1.7 22.1 13 36 6 35 305 -17.4 0 -16.9 -17.5 12/20/2005 22:00:00 16.9 1.9 21.4 12.2 16.6 2 22.1 11.8 35 6 42 305 -17.4 0 -17.1 -17.5 12/20/2005 22:10:00 17.8 1.8 21.8 12.2 17.5 1.9 21.4 12.6 36 6 33 305 -17.4 0 -17.1 -17.5 12/20/2005 22:20:00 17.3 1.9 21.8 12.6 17.1 1.8 22.6 12.6 35 6 36 305 -17.3 0 -17.1 -17.5 12/20/2005 22:30:00 17.5 2.3 23.3 12.2 17.2 2.3 23.3 12.2 35 6 32 305 -17.3 0.1 -16.9 -17.5 12/20/2005 22:40:00 17.3 1.9 21.8 11.8 16.9 2 21.8 12.2 37 5 34 305 -17.4 0 -17.1 -17.5 12/20/2005 22:50:00 16.9 1.6 21 13.3 16.6 1.6 20.6 13 37 6 33 305 -17.3 0.1 -16.9 -17.5 12/20/2005 23:00:00 16.4 1.7 20.2 11.8 16.1 1.7 19.9 11.1 37 6 37 305 -17.3 0 -16.9 -17.5 12/20/2005 23:10:00 16.1 1.6 19.9 12.6 15.9 1.6 20.2 12.2 35 6 31 305 -17.1 0 -16.9 -17.3 12/20/2005 23:20:00 15.6 1.6 20.6 11.8 15.4 1.5 19.9 11.8 35 6 27 305 -17.1 0 -16.9 -17.3 12/20/2005 23:30:00 16.2 1.7 20.6 11.8 15.9 1.7 20.6 11.8 35 6 32 305 -17.2 0 -16.9 -17.3 12/20/2005 23:40:00 16.7 2 23.3 12.2 16.4 1.9 21.8 12.2 34 6 30 305 -17.1 0 -16.9 -17.3 12/20/2005 23:50:00 17.4 1.7 22.1 12.6 17.2 1.7 21 13 35 6 32 305 -17.1 0 -16.9 -17.3 12/21/2005 00:00:00 16.3 1.7 20.2 12.2 16 1.8 19.9 11.8 35 7 38 305 -17.1 0 -16.9 -17.1 12/21/2005 00:10:00 16.6 2.3 22.9 11.5 16.4 2.3 23.7 11.1 33 6 30 305 -17 0 -16.7 -17.1 12/21/2005 00:20:00 15.7 1.7 20.2 11.8 15.4 1.7 19.9 11.5 31 6 18 305 -16.9 0 -16.6 -16.9 12/21/2005 00:30:00 16.4 1.7 21.4 11.5 16 1.6 20.2 12.2 31 6 31 305 -16.8 0 -16.4 -16.9 12/21/2005 00:40:00 16.8 1.7 22.1 12.2 16.4 1.7 21.4 12.6 29 6 35 305 -16.6 0 -16.2 -16.7 12/21/2005 00:50:00 17.3 1.7 21.4 13 16.8 1.7 21.4 13 28 6 33 305 -16.4 0 -16 -16.6 12/21/2005 01:00:00 15.8 3.1 23.7 8.4 15.5 2.9 23.3 8.8 27 6 28 305 -16.4 0 -16 -16.6 12/21/2005 01:10:00 16.8 2.4 23.3 10.7 16.4 2.4 23.3 10.3 28 6 24 305 -16.4 0 -16 -16.6 12/21/2005 01:20:00 17.4 2.4 23.3 11.5 17 2.4 21.8 11.1 30 6 30 305 -16.4 0 -16 -16.6 12/21/2005 01:30:00 17.5 2.3 22.9 12.2 17 2 22.9 12.2 29 6 26 305 -16.3 0 -16 -16.6 12/21/2005 01:40:00 18.1 1.8 23.3 13 17.5 1.8 23.7 13.7 29 6 28 305 -16.3 0 -16 -16.6 12/21/2005 01:50:00 17.1 2 22.9 12.6 16.7 1.9 22.1 12.6 30 6 23 305 -16.2 0.1 -15.8 -16.6 12/21/2005 02:00:00 18.3 2.5 24 12.2 17.8 2.4 23.3 11.8 29 6 27 305 -16.1 0.1 -15.8 -16.4 12/21/2005 02:10:00 17.9 1.8 23.7 13 17.5 1.8 23.3 13 27 5 23 305 -16 0 -15.8 -16.2 12/21/2005 02:20:00 17.2 2.1 22.1 12.2 16.7 2 21.8 12.2 27 7 32 305 -16 0 -15.8 -16.2 12/21/2005 02:30:00 14.2 1.7 17.9 10.3 13.9 1.6 17.2 10.3 16 5 17 305 -16.9 0.3 -16 -17.3 12/21/2005 02:40:00 13.9 1.3 16.4 10.7 13.7 1.3 16.4 10.7 17 5 9 305 -17.3 0.1 -16.9 -17.5 12/21/2005 02:50:00 14.6 1.9 18.7 10.3 14.2 1.9 19.1 9.5 18 5 16 305 -17.5 0.1 -17.3 -17.7 12/21/2005 03:00:00 16 1.5 19.5 11.8 15.5 1.5 18.7 11.1 19 5 23 305 -17.6 0 -17.3 -17.9 12/21/2005 03:10:00 15.8 1.3 18.7 11.8 15.4 1.3 19.5 11.5 19 5 14 305 -17.7 0 -17.5 -17.9 12/21/2005 03:20:00 14 1.7 19.1 10.3 13.8 1.7 19.5 9.5 18 5 20 305 -17.7 0 -17.5 -17.9 12/21/2005 03:30:00 13.9 1.5 17.2 10.3 13.6 1.5 16.8 10.3 22 5 30 305 -17.5 0 -17.1 -17.7 12/21/2005 03:40:00 13.5 2.5 20.2 9.1 13.2 2.4 19.9 9.1 27 6 36 305 -17.2 0.1 -16.9 -17.5 12/21/2005 03:50:00 16.2 2 21 12.6 15.8 2 20.2 11.5 29 6 33 305 -16.7 0 -16.6 -16.9 12/21/2005 04:00:00 17.8 2.1 21.8 11.5 17.3 2 21.4 10.7 33 6 35 305 -16.6 0 -16.2 -16.7 12/21/2005 04:10:00 17.5 2 22.1 12.2 17 1.8 21.4 13 30 6 29 305 -16.6 0 -16.2 -16.7 12/21/2005 04:20:00 16.5 2 21.4 11.8 16.1 2 20.6 11.1 29 6 25 305 -16.5 0 -16.2 -16.7 12/21/2005 04:30:00 16.2 1.7 20.2 11.8 15.9 1.5 20.2 12.2 29 8 45 305 -16.5 0 -16.2 -16.9 12/21/2005 04:40:00 14.6 1.5 18.7 10.7 14.5 1.5 18.3 10.7 17 5 16 305 -17.3 0.1 -16.6 -17.5 12/21/2005 04:50:00 13.7 1.7 18.3 9.9 13.5 1.7 17.9 9.9 17 5 20 305 -17.4 0 -17.1 -17.5 12/21/2005 05:00:00 14.3 1.6 17.9 9.9 14 1.6 17.6 9.9 18 5 13 305 -17.4 0 -17.1 -17.5 12/21/2005 05:10:00 14.3 1.5 18.3 11.1 14 1.6 17.9 10.3 20 6 15 305 -17.5 0 -17.1 -17.5 12/21/2005 05:20:00 14.6 2.8 22.9 9.9 14.3 2.7 23.3 9.9 25 6 23 305 -17.2 0.2 -16.4 -17.5 12/21/2005 05:30:00 19.2 1.7 22.9 14.5 18.6 1.7 22.6 14.5 30 5 25 305 -16.4 0 -16 -16.6 12/21/2005 05:40:00 18.7 1.9 23.7 14.1 18.3 1.8 22.6 14.1 31 5 32 305 -16.3 0.1 -16 -16.4 12/21/2005 05:50:00 18.4 2.1 22.6 13 18 2.1 22.6 12.6 33 6 35 305 -16.3 0.1 -16 -16.6 12/21/2005 06:00:00 17.9 1.9 22.6 12.6 17.3 1.9 22.1 12.6 30 6 27 305 -16.2 0.1 -16 -16.4 12/21/2005 06:10:00 18.3 2.1 23.3 13.3 17.8 2.1 23.7 13 29 6 33 305 -16.2 0.1 -16 -16.4 12/21/2005 06:20:00 18.1 1.9 22.6 14.1 17.6 1.8 22.6 13.7 30 6 39 305 -16.2 0.1 -15.8 -16.4 12/21/2005 06:30:00 16.5 1.7 21 11.8 16.3 1.8 21.4 11.1 31 5 30 305 -16.2 0.1 -16 -16.4 12/21/2005 06:40:00 14.9 1.6 20.2 10.3 14.7 1.6 20.2 11.1 22 9 21 305 -16.5 0.4 -15.8 -17.5 12/21/2005 06:50:00 14.2 1.5 18.3 10.3 14 1.5 17.6 10.7 16 6 13 305 -17.4 0 -16.9 -17.5 12/21/2005 07:00:00 13.7 1.4 17.6 10.3 13.6 1.4 17.2 10.3 18 5 18 305 -17.4 0.1 -16.9 -17.5 12/21/2005 07:10:00 13 1.3 16.1 9.1 12.8 1.3 16.4 9.5 18 5 22 305 -17.4 0 -16.9 -17.5 12/21/2005 07:20:00 15.8 2.1 19.5 11.1 15.5 2.1 19.5 10.3 25 6 26 305 -16.4 0.4 -15.8 -17.5 12/21/2005 07:30:00 15 1.6 20.2 11.5 14.7 1.5 19.1 11.1 27 5 26 305 -16 0.1 -15.6 -16.4 12/21/2005 07:40:00 14.3 1.6 19.5 11.1 14.1 1.5 19.1 10.3 28 5 30 305 -15.9 0 -15.8 -16.2 12/21/2005 07:50:00 15.9 1.7 19.9 11.1 15.5 1.7 20.2 11.1 29 5 27 305 -15.8 0 -15.6 -16 12/21/2005 08:00:00 15.1 1.7 20.6 10.7 14.9 1.7 20.6 11.1 29 6 40 305 -15.8 0 -15.2 -16 12/21/2005 08:10:00 16.4 1.7 20.6 12.6 16 1.6 19.9 12.6 29 6 32 305 -15.8 0.1 -15.2 -15.8 12/21/2005 08:20:00 17.1 1.9 21.4 12.6 16.8 1.9 21.8 11.8 29 6 29 305 -15.7 0.1 -15.2 -15.8 12/21/2005 08:30:00 16.4 2 22.1 11.5 16.2 2 21.8 11.5 29 7 45 305 -15.6 0 -15 -15.8 12/21/2005 08:40:00 15.6 1.7 20.6 11.5 15.3 1.7 20.2 11.8 30 6 35 305 -15.6 0.1 -15 -15.8 12/21/2005 08:50:00 15.7 1.7 20.6 11.1 15.5 1.7 19.9 11.5 27 9 31 305 -15.7 0.1 -15.2 -16.4 12/21/2005 09:00:00 14.4 1.7 17.9 10.7 14.2 1.7 17.6 10.3 14 5 16 305 -16.9 0.2 -16.4 -17.3 12/21/2005 09:10:00 13.8 1.4 17.2 10.3 13.6 1.3 17.9 10.3 15 5 9 305 -17.3 0 -16.9 -17.5 12/21/2005 09:20:00 13 1.3 15.6 10.3 13 1.2 15.6 9.9 16 5 8 305 -17.1 0 -16.9 -17.3 12/21/2005 09:30:00 13.3 1.1 15.6 10.7 13.1 1.2 16.4 10.3 15 4 12 305 -17.1 0 -16.9 -17.3 12/21/2005 09:40:00 13 1.1 15.6 10.3 13 1.1 16.1 10.3 18 5 14 305 -16.9 0 -16.9 -17.1 12/21/2005 09:50:00 12.6 1.1 15.6 9.9 12.6 1.1 15.6 9.9 19 5 17 305 -16.7 0.1 -16.2 -16.9 12/21/2005 10:00:00 12.2 1 14.9 9.9 12.2 1 14.5 9.5 22 5 17 305 -16.4 0.1 -16 -16.6 12/21/2005 10:10:00 12.9 2.2 17.9 8.8 12.7 2.1 17.6 9.1 28 7 37 305 -15.9 0.3 -15 -16.4 12/21/2005 10:20:00 14.7 1.2 17.6 11.1 14.3 1.3 17.2 11.5 26 5 28 305 -15.3 0.1 -14.8 -15.6 12/21/2005 10:30:00 14.4 1.4 17.9 11.1 14.1 1.3 17.6 11.1 26 6 19 305 -15.2 0.1 -14.6 -15.4 12/21/2005 10:40:00 14.4 1.6 18.7 9.9 14.2 1.6 17.9 9.9 23 5 20 305 -15.2 0.1 -14.8 -15.4 12/21/2005 10:50:00 15 1.5 18.7 11.1 14.7 1.5 18.3 10.7 23 6 23 305 -15.3 0.1 -14.8 -15.6 12/21/2005 11:00:00 13.3 1.8 18.7 9.1 13.2 1.8 17.9 9.9 17 5 14 305 -15.7 0.2 -15 -16 12/21/2005 11:10:00 13.7 1.6 17.6 9.9 13.5 1.5 17.2 9.5 12 5 21 305 -16.2 0.2 -15.6 -16.6 12/21/2005 11:20:00 14.5 1.6 17.9 10.3 14.2 1.5 17.9 10.3 16 5 12 305 -16.4 0.1 -16 -16.7 12/21/2005 11:30:00 13.4 1.5 17.6 9.9 13.2 1.5 17.2 9.1 15 5 10 305 -16.6 0.1 -16.2 -16.9 12/21/2005 11:40:00 12.9 1.7 16.8 8.8 12.9 1.7 16.8 8.8 14 5 12 305 -16.6 0.1 -16.2 -16.9 12/21/2005 11:50:00 12.6 1.4 16.1 8.8 12.7 1.4 16.4 9.1 15 5 8 305 -16.5 0.1 -16 -16.6 12/21/2005 12:00:00 13.2 1.3 16.1 9.9 13.2 1.3 16.4 9.9 14 5 13 305 -16.4 0 -16 -16.6 12/21/2005 12:10:00 13.5 1.5 17.2 9.5 13.5 1.5 16.4 9.9 14 5 8 305 -16.3 0 -16 -16.6 12/21/2005 12:20:00 12.7 1.1 16.1 9.9 12.7 1.2 16.4 9.5 14 5 16 305 -16.2 0 -16 -16.4 12/21/2005 12:30:00 12 1.4 17.2 8.8 11.9 1.3 16.4 9.1 20 6 21 305 -15.8 0.1 -14.8 -16 12/21/2005 12:40:00 14.6 1.6 18.3 9.9 14.4 1.5 18.7 11.5 24 6 23 305 -14.8 0.1 -14.6 -15.4 12/21/2005 12:50:00 13.7 1.5 17.6 10.3 13.4 1.5 17.6 9.5 23 6 23 305 -14.7 0 -14.4 -15 12/21/2005 13:00:00 16 2 21 11.1 15.8 2 20.6 11.1 21 6 19 305 -14.6 0.1 -14.3 -14.8 12/21/2005 13:10:00 15.2 1.9 19.5 10.3 14.9 2.1 19.9 9.9 8 5 7 305 -15.6 0.3 -14.4 -16 12/21/2005 13:20:00 13 1.4 16.1 9.5 13 1.4 16.1 9.5 8 5 14 305 -16 0.1 -15.8 -16.4 12/21/2005 13:30:00 11.9 1.1 14.5 8.8 11.8 1.1 14.5 8.8 8 5 1 305 -16.2 0 -15.8 -16.4 12/21/2005 13:40:00 13.3 1.3 16.8 9.5 13.1 1.3 16.8 9.5 11 5 10 305 -15.9 0 -15.6 -16.2 12/21/2005 13:50:00 12.8 1.4 16.8 9.5 12.8 1.5 17.2 9.5 13 6 14 305 -15.7 0 -15.2 -15.8 12/21/2005 14:00:00 12.2 1.5 16.4 8.4 12 1.5 16.4 8.8 13 6 11 305 -15.5 0 -15 -15.6 12/21/2005 14:10:00 11.5 1.1 14.5 9.1 11.3 1.1 14.5 8.4 16 6 15 305 -15.2 0.1 -14.4 -15.4 12/21/2005 14:20:00 12.5 1.1 16.1 9.5 12.3 1.2 15.3 8.8 21 5 21 305 -14.5 0.1 -14.3 -15 12/21/2005 14:30:00 15.1 2.2 20.6 10.7 14.8 2.1 20.2 9.5 23 6 17 305 -13.8 0.2 -13.3 -14.3 12/21/2005 14:40:00 14.8 1.8 18.7 10.7 14.5 1.7 18.3 10.3 22 6 22 305 -13.7 0.2 -13.3 -13.9 12/21/2005 14:50:00 14 1.6 17.9 9.9 13.9 1.7 17.9 10.7 22 6 34 305 -13.7 0.1 -13.3 -13.9 12/21/2005 15:00:00 14 1.5 17.6 10.3 13.9 1.5 17.6 10.3 16 7 14 305 -13.7 0.3 -13.1 -14.4 12/21/2005 15:10:00 13.5 1.3 16.4 9.5 13.4 1.4 16.8 9.9 10 6 0 305 -14.4 0.2 -13.9 -14.6 12/21/2005 15:20:00 13.4 1.4 17.2 9.9 13.2 1.4 16.8 9.5 12 5 9 305 -14.6 0.2 -14.3 -14.6 12/21/2005 15:30:00 13.5 1.4 16.8 10.3 13.4 1.5 16.8 9.9 13 5 10 305 -14.6 0.2 -14.3 -14.8 12/21/2005 15:40:00 13.1 1.5 16.4 9.9 12.9 1.5 16.4 9.1 17 6 19 305 -14.4 0.2 -13.9 -14.6 12/21/2005 15:50:00 13.2 1.4 16.4 9.9 13 1.4 16.8 9.5 22 6 21 305 -13.9 0.3 -13.1 -14.4 12/21/2005 16:00:00 16 1.8 21 11.8 15.7 1.8 20.6 11.1 22 6 20 305 -13.4 0.2 -12.9 -13.7 12/21/2005 16:10:00 15.1 1.5 19.9 11.1 14.9 1.5 20.2 10.7 22 6 31 305 -13.3 0.2 -12.9 -13.7 12/21/2005 16:20:00 15.3 2 19.5 10.7 15.1 1.9 19.5 10.3 24 6 16 305 -13.2 0.2 -12.9 -13.5 12/21/2005 16:30:00 15.7 1.8 21 11.8 15.4 1.9 20.2 11.5 24 5 28 305 -13.2 0.1 -12.9 -13.5 12/21/2005 16:40:00 15.5 1.8 20.6 11.5 15.3 1.7 19.9 11.5 24 6 21 305 -13.2 0.1 -12.9 -13.5 12/21/2005 16:50:00 15.4 2.1 20.2 10.3 15 2.1 21 10.3 22 6 19 305 -13.2 0 -12.9 -13.5 12/21/2005 17:00:00 16.2 2 21 11.8 15.9 1.9 21 10.7 23 6 25 305 -13.2 0 -12.7 -13.3 12/21/2005 17:10:00 16.9 1.9 21.8 12.2 16.6 1.9 21.4 11.5 21 6 19 305 -13.2 0 -12.7 -13.3 12/21/2005 17:20:00 16.7 1.6 20.2 11.5 16.4 1.5 19.9 11.5 24 6 23 305 -13.1 0 -12.7 -13.3 12/21/2005 17:30:00 15.5 1.6 19.9 11.8 15.2 1.5 19.5 11.1 23 6 26 305 -13.2 0.1 -12.7 -13.3 12/21/2005 17:40:00 15.6 1.9 19.9 11.5 15.3 1.9 19.9 11.5 24 6 15 305 -13.2 0 -12.7 -13.3 12/21/2005 17:50:00 15.1 2 21 11.5 14.8 1.8 21 11.5 25 6 17 305 -13.2 0 -12.5 -13.3 12/21/2005 18:00:00 16.2 2 21.4 11.5 15.8 1.9 21 11.8 24 6 17 305 -13.2 0.1 -12.7 -13.3 12/21/2005 18:10:00 15.7 1.7 19.5 11.1 15.4 1.7 19.1 11.1 24 6 25 305 -13.2 0 -12.7 -13.3 12/21/2005 18:20:00 16.5 1.6 20.6 13 16.2 1.5 20.2 12.6 23 6 27 305 -13.3 0 -12.9 -13.5 12/21/2005 18:30:00 16.3 1.7 20.6 11.5 16 1.6 20.2 11.1 25 6 29 305 -13.3 0 -12.9 -13.5 12/21/2005 18:40:00 16.9 1.7 21.4 11.1 16.5 1.9 21.4 11.1 21 5 21 305 -13.5 0.1 -12.9 -13.7 12/21/2005 18:50:00 16.9 1.5 21.4 13 16.5 1.5 20.6 12.2 23 5 25 305 -13.6 0 -13.3 -13.7 12/21/2005 19:00:00 17.2 1.9 22.1 12.6 16.8 2 22.1 11.8 22 6 26 305 -13.7 0.1 -13.3 -13.9 12/21/2005 19:10:00 16.9 2.2 22.1 11.1 16.7 2.1 21.8 11.5 22 6 19 305 -13.7 0.1 -13.3 -14.1 12/21/2005 19:20:00 17.7 1.8 22.1 12.6 17.5 1.8 22.1 13.7 19 6 19 305 -13.9 0.2 -13.3 -14.3 12/21/2005 19:30:00 15.7 2.2 21.8 10.7 15.4 2.1 21.4 9.9 18 6 13 305 -14 0.2 -13.5 -14.3 12/21/2005 19:40:00 16.1 2.3 21.4 11.1 16 2.3 21.4 11.5 18 6 18 305 -13.9 0.2 -13.5 -14.3 12/21/2005 19:50:00 15.7 1.9 21.4 11.5 15.5 2 21.8 11.5 19 5 17 305 -13.9 0.2 -13.5 -14.3 12/21/2005 20:00:00 15.9 2.4 21.8 10.3 15.6 2.4 21.8 10.3 22 6 22 305 -14 0.2 -13.5 -14.3 12/21/2005 20:10:00 16.1 2.1 22.9 11.1 15.8 2.1 22.6 11.5 21 7 17 305 -14 0.1 -13.5 -14.3 12/21/2005 20:20:00 16.6 2.4 22.6 11.8 16.2 2.3 21.8 11.8 23 6 13 305 -14 0.2 -13.5 -14.3 12/21/2005 20:30:00 16.9 2.1 21.8 12.2 16.6 2.1 21.4 11.5 22 6 24 305 -14 0.2 -13.7 -14.3 12/21/2005 20:40:00 16.3 2.3 21.4 10.7 16 2.1 20.6 10.3 23 6 22 305 -14.1 0.1 -13.7 -14.3 12/21/2005 20:50:00 17.2 2 22.9 11.8 16.9 2 23.7 12.2 22 6 22 305 -14.1 0.2 -13.7 -14.3 12/21/2005 21:00:00 17 2.2 23.3 11.8 16.7 2.1 22.1 11.8 21 6 18 305 -14.1 0.1 -13.7 -14.3 12/21/2005 21:10:00 17.2 2.3 22.9 11.8 16.9 2.2 22.9 11.8 20 6 26 305 -14.1 0.1 -13.7 -14.3 12/21/2005 21:20:00 16.4 2.2 21 11.5 16.1 2.1 21.4 11.5 20 6 24 305 -14.2 0 -14.1 -14.4 12/21/2005 21:30:00 16.6 2.1 21.4 10.7 16.3 2.1 20.2 10.7 20 6 18 305 -14.2 0 -13.9 -14.3 12/21/2005 21:40:00 16.7 2 21.4 12.2 16.5 2 21.4 11.5 19 6 15 305 -14.2 0 -13.7 -14.3 12/21/2005 21:50:00 16.4 1.8 20.6 11.8 16.1 1.8 20.2 11.1 18 7 25 305 -14.2 0 -13.9 -14.3 12/21/2005 22:00:00 15.9 1.9 20.2 11.1 15.8 1.9 20.6 11.5 17 6 15 305 -14.2 0 -13.7 -14.3 12/21/2005 22:10:00 16.2 1.8 20.2 10.7 16 1.9 21 11.1 20 7 19 305 -14.2 0.1 -13.5 -14.3 12/21/2005 22:20:00 16.7 2.2 21.8 12.2 16.3 2.1 21.4 11.5 22 6 16 305 -14 0.4 -12.5 -14.3 12/21/2005 22:30:00 17 2 21.8 12.6 16.7 2 21.4 11.1 21 5 27 305 -13 0.2 -12.5 -13.7 12/21/2005 22:40:00 17.4 2.1 22.6 11.8 17.2 2 22.1 12.6 21 6 22 305 -12.6 0.1 -12.1 -13.3 12/21/2005 22:50:00 16.3 2.1 21.4 11.5 15.9 2.1 21.8 11.1 22 7 28 305 -12.2 0.2 -11.7 -13.3 12/21/2005 23:00:00 16.7 1.9 21 12.2 16.4 1.8 20.6 11.5 22 5 24 305 -12.3 0.2 -11.5 -12.9 12/21/2005 23:10:00 15.1 1.9 20.2 11.5 14.9 1.9 20.6 11.1 20 7 16 305 -10.9 1.4 -8.8 -13.1 12/21/2005 23:20:00 15.5 2.3 21 10.3 15.4 2.3 21 9.9 19 6 23 305 -10.1 0.5 -9.6 -14.6 12/21/2005 23:30:00 16.6 1.8 20.6 10.7 16.4 1.7 19.9 11.5 19 5 21 305 -7.6 1.6 -5.3 -12.1 12/21/2005 23:40:00 15.9 1.7 21 11.8 15.7 1.7 20.6 11.1 21 6 23 305 -6.7 0.5 -5.8 -9.2 12/21/2005 23:50:00 15.4 1.7 20.2 11.5 15 1.6 19.5 10.7 21 7 17 305 -6 0.6 -4.7 -7.9 12/22/2005 00:00:00 17.2 2 22.1 12.2 16.9 1.8 21.4 12.2 23 6 32 305 -6.7 0.3 -5.8 -7.5 12/22/2005 00:10:00 15.9 1.7 19.9 11.8 15.5 1.7 19.5 11.5 21 6 14 305 -6.7 0.4 -5.6 -8.4 12/22/2005 00:20:00 13.9 2.3 22.6 9.9 13.7 2.2 22.6 9.5 23 7 20 305 -6.1 0.7 -4.7 -14.4 12/22/2005 00:30:00 17.9 1.7 21.8 13.3 17.6 1.7 22.1 12.6 27 6 27 305 -6 0.4 -4.9 -10.2 12/22/2005 00:40:00 16.4 2.2 21.8 9.9 16.1 2.1 21.4 10.3 27 7 31 305 -5.8 0.5 -4.7 -7.9 12/22/2005 00:50:00 14.7 2 19.9 10.7 14.5 1.9 20.2 10.3 26 7 46 305 -6.9 0.4 -5.8 -8.4 12/22/2005 01:00:00 15.4 1.8 19.5 11.1 15 1.8 19.9 11.1 23 6 17 305 -7.2 0.4 -6 -8.6 12/22/2005 01:10:00 15.5 1.8 20.6 11.1 15.3 1.7 20.2 11.1 26 6 25 305 -7.6 0.6 -5.8 -9.6 12/22/2005 01:20:00 17 1.7 21.8 12.2 16.8 1.9 21.4 11.8 25 6 29 305 -6.9 0.5 -5.8 -8.8 12/22/2005 01:30:00 16.9 2 22.1 12.6 16.6 2 22.1 11.8 23 5 20 305 -7 0.3 -6 -9.4 12/22/2005 01:40:00 16.5 2.1 21.8 11.8 16.3 1.8 21.4 11.5 24 6 29 305 -7 0.2 -6.2 -7.5 12/22/2005 01:50:00 17.2 2 23.7 12.6 16.9 1.9 22.6 11.8 23 6 32 305 -8 0.8 -6.4 -10 12/22/2005 02:00:00 17.5 1.8 21.8 13 17.1 1.7 21.4 13.3 24 5 22 305 -8 0.4 -7.1 -9.2 12/22/2005 02:10:00 17.7 2 22.1 11.8 17.3 1.9 22.1 12.2 23 6 23 305 -9.5 0.8 -7.9 -11.1 12/22/2005 02:20:00 16.4 2.2 21.4 10.7 16.1 2 21 10.7 24 6 29 305 -8.2 0.5 -6.9 -9.8 12/22/2005 02:30:00 16.9 1.7 20.6 12.6 16.6 1.7 21 11.5 23 5 13 305 -7.2 0.3 -6 -8.6 12/22/2005 02:40:00 16.3 2 22.1 12.2 15.9 2 21.8 11.1 24 6 18 305 -7.2 0.5 -6 -8.2 12/22/2005 02:50:00 16.7 2.1 21.8 12.2 16.6 2.1 21.8 11.8 22 6 23 305 -7 0.4 -6 -8.2 12/22/2005 03:00:00 16.5 1.8 20.6 11.1 16.2 1.7 21.4 11.5 23 5 23 305 -6.7 0.7 -5.6 -12.1 12/22/2005 03:10:00 15.5 2.2 20.6 11.1 15.2 2.1 20.2 9.9 23 6 16 305 -5.7 1 -4 -10.4 12/22/2005 03:20:00 15.8 2.1 20.6 11.5 15.6 2 20.2 10.7 24 6 24 305 -4.5 0.5 -3.6 -6.7 12/22/2005 03:30:00 14.9 2.1 19.9 9.9 14.7 2 20.2 9.9 23 6 27 305 -4.6 0.9 -3.6 -10.4 12/22/2005 03:40:00 15.8 2.1 21 10.3 15.5 2.1 21.4 9.5 28 6 29 305 -5.2 0.8 -3.8 -8.8 12/22/2005 03:50:00 16.1 1.8 20.6 10.7 15.7 1.7 19.9 11.5 26 6 29 305 -5.5 0.8 -4 -8.2 12/22/2005 04:00:00 15.5 2.1 20.2 10.7 15.2 2 19.5 10.7 24 7 14 305 -6.8 0.7 -5.6 -9.6 12/22/2005 04:10:00 15.5 2 20.6 10.7 15.1 1.9 20.6 11.1 24 6 19 305 -7.1 0.7 -5.6 -9.4 12/22/2005 04:20:00 15.9 2 20.6 11.1 15.4 2 20.2 11.5 26 6 31 305 -7.4 1 -5.6 -11.3 12/22/2005 04:30:00 15.4 1.7 19.9 10.7 15.1 1.5 18.7 11.1 26 6 22 305 -6.3 1 -4.9 -10.4 12/22/2005 04:40:00 14.7 1.5 19.5 10.7 14.4 1.5 19.1 10.7 25 6 15 305 -7.1 1.8 -3.6 -12.7 12/22/2005 04:50:00 15.7 1.8 20.6 11.5 15.4 1.7 19.9 11.1 25 6 22 305 -4.5 1.2 -3.3 -7.9 12/22/2005 05:00:00 16.9 2 21.8 10.3 16.5 1.9 21.8 10.7 23 7 30 305 -5.2 1.5 -3.3 -10 12/22/2005 05:10:00 16 1.7 19.5 11.5 15.8 1.7 19.5 10.7 23 6 22 305 -6.5 1.7 -4 -11.7 12/22/2005 05:20:00 13.5 1.9 17.9 8.4 13.4 1.9 17.9 8.8 22 6 21 305 -4.9 0.7 -3.8 -8.2 12/22/2005 05:30:00 15.3 1.7 19.1 11.1 14.9 1.8 18.7 10.7 22 6 21 305 -4.4 0.4 -3.8 -7.7 12/22/2005 05:40:00 14.4 1.8 19.1 10.7 14 1.7 19.9 10.3 22 7 18 305 -4.3 0.7 -3.6 -7.7 12/22/2005 05:50:00 16.1 1.7 21 12.2 15.7 1.7 20.6 12.2 26 6 23 305 -3.7 0.8 -2.2 -7.3 12/22/2005 06:00:00 15.3 1.7 19.1 10.7 14.9 1.7 19.5 10.7 27 6 25 305 -2.7 0.1 -2.2 -3.6 12/22/2005 06:10:00 14.4 1.7 19.1 10.7 13.9 1.7 19.5 10.3 27 6 19 305 -2.8 0.4 -2 -6.4 12/22/2005 06:20:00 13.9 2 17.9 8.4 13.5 2 17.9 8.8 23 6 24 305 -3 0.4 -2 -6.4 12/22/2005 06:30:00 14.5 1.9 19.5 9.9 14.2 1.9 19.1 9.9 26 5 35 305 -4.5 0.6 -2.9 -7.9 12/22/2005 06:40:00 13.4 1.6 17.6 8.8 13.2 1.5 16.8 9.5 27 7 34 305 -3.6 0.7 -2.7 -7.7 12/22/2005 06:50:00 13.2 1.9 17.9 8.4 12.9 1.9 17.9 8.4 23 6 18 305 -3.1 0.5 -2.4 -6.7 12/22/2005 07:00:00 13.3 1.7 17.2 9.1 13 1.8 17.6 8.8 25 7 18 305 -3.2 0.1 -2.7 -3.8 12/22/2005 07:10:00 13.7 1.7 18.3 9.1 13.3 1.7 17.6 9.5 24 7 30 305 -3.1 0.4 -2.2 -6.7 12/22/2005 07:20:00 13.4 2 18.3 8.8 13.1 2 17.2 9.1 24 6 24 305 -3.3 0.6 -2.4 -7.1 12/22/2005 07:30:00 14.2 1.7 17.9 10.3 13.9 1.7 17.9 9.9 24 6 20 305 -2.8 0.3 -2.2 -6.2 12/22/2005 07:40:00 12.2 1.9 16.8 8 12 1.8 16.1 8.4 27 7 22 305 -2.4 0.2 -1.8 -6 12/22/2005 07:50:00 11.7 1.7 16.1 8.4 11.3 1.6 15.6 8 24 7 32 305 -2.6 0.5 -2 -6.2 12/22/2005 08:00:00 11.2 1.6 15.6 8 10.9 1.7 15.6 8 22 7 19 305 -2.5 0.1 -2 -3.1 12/22/2005 08:10:00 12.7 1.7 16.4 8.8 12.5 1.7 16.4 8.8 25 6 19 305 -2.6 0.1 -2.2 -3.3 12/22/2005 08:20:00 12.8 1.7 17.6 8.8 12.4 1.6 16.8 8.8 25 6 32 305 -2.4 0.1 -2 -3.8 12/22/2005 08:30:00 12.5 1.7 17.6 8 12.3 1.7 17.2 8 25 6 22 305 -2.3 0.3 -1.8 -5.8 12/22/2005 08:40:00 10.4 1.3 14.1 7.6 10.3 1.3 14.9 7.2 25 7 22 305 -2.3 1 -1.1 -6.7 12/22/2005 08:50:00 12.5 2.2 16.8 6.8 12.3 2.2 16.8 6.8 19 6 20 305 -4.5 0.8 -2.9 -6.2 12/22/2005 09:00:00 13.5 1.4 16.8 9.5 13.4 1.5 17.2 9.5 20 6 23 305 -4.1 1.3 -2 -9.2 12/22/2005 09:10:00 13.7 1.5 17.6 9.1 13.3 1.3 16.8 9.9 25 6 27 305 -3.4 0.7 -2 -6.4 12/22/2005 09:20:00 11.8 1.6 16.1 8.4 11.6 1.6 15.3 8.4 20 6 17 305 -3.5 0.4 -2.7 -6.9 12/22/2005 09:30:00 12.5 1.3 16.1 9.5 12.4 1.3 16.4 9.5 23 7 31 305 -3.3 0.4 -2.7 -7.1 12/22/2005 09:40:00 12.1 1.7 16.4 8.4 12 1.7 16.4 8.8 26 6 30 305 -3.7 0.4 -2.7 -7.1 12/22/2005 09:50:00 12.3 1.9 16.4 8.4 12.1 1.9 16.4 8.4 26 6 25 305 -3.5 0.7 -1.8 -6.2 12/22/2005 10:00:00 12.9 1.3 16.4 9.5 12.5 1.4 16.4 9.1 27 7 31 305 -3.7 0.3 -3.1 -5.8 12/22/2005 10:10:00 13.7 1.7 17.2 9.5 13.5 1.6 16.8 8.8 23 7 14 305 -3.7 0.4 -2.4 -5.6 12/22/2005 10:20:00 13.9 1.7 17.9 8.8 13.7 1.7 17.9 9.5 21 6 17 305 -3.3 0.7 -2 -6 12/22/2005 10:30:00 11.7 1.4 15.3 8.4 11.5 1.3 15.3 8.8 20 6 17 305 -2.8 0.3 -2 -3.8 12/22/2005 10:40:00 12.4 1.5 17.2 8.4 12.2 1.7 16.8 8 21 6 23 305 -2.4 0.2 -2 -3.1 12/22/2005 10:50:00 12.7 1.4 16.8 9.1 12.4 1.3 16.1 9.1 23 7 19 305 -2.3 0.6 -1.3 -4.2 12/22/2005 11:00:00 12.8 1.5 16.1 8.8 12.6 1.5 16.1 9.1 17 6 17 305 -3.3 0.1 -2.7 -3.8 12/22/2005 11:10:00 11.4 1.5 16.1 8 11.1 1.4 15.3 8 22 6 24 305 -3.7 0.4 -2.4 -5.3 12/22/2005 11:20:00 12.8 1.6 16.8 8.8 12.6 1.6 16.1 8.8 23 7 31 305 -3.9 0.3 -3.1 -5.6 12/22/2005 11:30:00 12.2 1.2 15.3 8.8 12.1 1.2 14.9 8.8 24 5 18 305 -3.7 0.3 -3.1 -5.1 12/22/2005 11:40:00 12.1 1.3 15.3 9.1 11.9 1.2 15.3 8.8 23 6 27 305 -3.6 0 -3.1 -3.8 12/22/2005 11:50:00 12 1.3 15.3 8.8 11.9 1.3 15.3 8.4 24 7 20 305 -3.7 0.2 -2.4 -4.9 12/22/2005 12:00:00 11.9 1.5 15.6 8 11.8 1.5 15.3 7.6 22 6 23 305 -3.7 0.2 -3.1 -4.9 12/22/2005 12:10:00 12.8 1.1 15.6 9.9 12.6 1.2 15.3 9.1 23 6 30 305 -3.3 0.4 -2.4 -3.8 12/22/2005 12:20:00 11.5 1.2 14.5 8.8 11.3 1.4 14.5 8.4 22 6 21 305 -2.5 0.4 -1.8 -3.8 12/22/2005 12:30:00 12.2 1.3 15.6 8.8 12.1 1.3 15.3 8.8 25 6 26 305 -2.3 0 -2 -2.7 12/22/2005 12:40:00 12.8 1.3 16.1 9.1 12.6 1.4 16.1 9.1 24 6 19 305 -2.8 0.4 -2 -4.5 12/22/2005 12:50:00 12.7 1.5 16.4 8.8 12.5 1.5 16.8 8.8 23 6 27 305 -2.4 0.2 -1.8 -2.7 12/22/2005 13:00:00 12.8 1.6 16.4 8.4 12.6 1.6 16.8 9.1 26 6 29 305 -1.6 0.3 -1.1 -5.1 12/22/2005 13:10:00 12 1.5 15.6 8 12 1.5 15.6 8.4 22 5 25 305 -1.4 0.2 -1.1 -2.2 12/22/2005 13:20:00 11.6 1.3 14.9 8.4 11.5 1.3 14.9 7.2 21 6 18 305 -4.4 1 -1.1 -6.7 12/22/2005 13:30:00 11.9 1.5 15.3 8 11.8 1.5 15.6 8 21 6 25 305 -3.1 1.7 -1.8 -6.4 12/22/2005 13:40:00 11.2 1.4 14.5 7.6 11 1.4 14.5 7.2 20 5 18 305 -1.9 0.2 -1.3 -3.1 12/22/2005 13:50:00 11.1 1.5 15.3 7.6 11 1.5 15.3 7.6 24 6 27 305 -2.2 0.2 -1.8 -3.1 12/22/2005 14:00:00 11.5 1.2 14.1 8.4 11.3 1.3 14.1 8 26 6 24 305 -2.4 0.2 -1.8 -3.1 12/22/2005 14:10:00 11.5 1.2 14.9 8.8 11.4 1.2 14.5 8 24 6 27 305 -2.5 0.2 -1.8 -3.1 12/22/2005 14:20:00 12 1.2 14.9 9.5 11.8 1.3 14.9 9.1 23 5 23 305 -2.3 0 -2 -2.7 12/22/2005 14:30:00 11.1 1.1 14.1 8.4 10.9 1.1 13.7 7.6 23 6 27 305 -2.5 0.1 -2 -3.8 12/22/2005 14:40:00 11.9 1.1 14.9 8.8 11.6 1.1 14.5 8.8 23 6 22 305 -2.5 0.1 -2 -3.8 12/22/2005 14:50:00 10.4 1.3 13 7.6 10.1 1.4 13 7.2 24 6 30 305 -1.4 1.2 2 -2.9 12/22/2005 15:00:00 9.2 1.1 12.2 6.5 9 1 11.8 6.1 25 6 19 305 1.9 0.3 2.5 1 12/22/2005 15:10:00 9.5 1.2 13.3 6.5 9.3 1.1 12.6 6.5 26 6 29 305 2 0.4 2.7 1 12/22/2005 15:20:00 10 1.3 12.6 6.8 9.8 1.2 13 6.8 25 6 19 305 2.3 0.1 2.7 1.5 12/22/2005 15:30:00 10 1.2 13 7.2 9.8 1.2 12.6 6.8 25 5 28 305 2.2 0.3 2.7 1.5 12/22/2005 15:40:00 10.2 1.3 13 6.8 9.9 1.3 13.3 6.5 26 6 34 305 2.2 0.2 2.9 1.3 12/22/2005 15:50:00 10.1 1.2 13.3 7.2 10 1.2 13.3 6.8 24 6 26 305 2.2 0.2 2.7 1.5 12/22/2005 16:00:00 9.6 1.2 12.6 6.8 9.5 1.2 12.6 6.8 24 6 32 305 1.8 0.5 2.7 0.3 12/22/2005 16:10:00 10 1 12.6 7.6 9.9 1 12.6 6.8 23 6 17 305 2.6 0.1 2.9 1 12/22/2005 16:20:00 10.5 1.2 13.3 6.8 10.3 1.3 13.3 7.2 23 6 22 305 2.6 0 2.9 2.2 12/22/2005 16:30:00 10.6 1.3 14.1 7.2 10.5 1.3 13.7 7.6 23 6 9 305 2.6 0 2.9 1 12/22/2005 16:40:00 11.9 1.3 15.6 9.1 11.7 1.4 14.5 8 24 6 14 305 2.3 0.2 2.7 1 12/22/2005 16:50:00 11.5 1.5 14.1 7.6 11.3 1.5 14.9 8.4 25 5 27 305 2.3 0.4 2.9 0.8 12/22/2005 17:00:00 11.5 1.6 14.5 7.6 11.3 1.6 15.3 7.2 25 6 25 305 2.5 0.4 3.4 1 12/22/2005 17:10:00 11.5 1.3 14.5 8.4 11.2 1.4 14.9 8 26 6 30 305 2.5 0.5 3.4 0.6 12/22/2005 17:20:00 10.9 1.2 13.7 8 10.8 1.3 13.7 7.6 27 6 33 305 2.5 0.5 3.4 0.8 12/22/2005 17:30:00 11.3 1.5 14.9 8 11.1 1.6 14.5 8 26 7 20 305 2.5 0.4 3.2 1.5 12/22/2005 17:40:00 11.1 1.2 14.5 8.4 10.8 1.2 14.5 8 27 6 27 305 0.3 0.7 2.5 -1.1 12/22/2005 17:50:00 11.9 1.4 15.3 8.4 11.5 1.5 15.3 8 28 5 28 305 0.6 0.4 2 -0.4 12/22/2005 18:00:00 12.1 1.3 15.3 8.4 11.6 1.4 15.3 8.4 28 6 32 305 1.2 0.5 2 -1.1 12/22/2005 18:10:00 10.8 1.2 13.7 8.4 10.6 1.2 14.1 8 31 6 25 305 1.3 0.5 2.5 -0.4 12/22/2005 18:20:00 10.8 1.1 13.3 7.2 10.5 1.1 13.7 8 32 5 32 305 0.8 0.5 2 -1.3 12/22/2005 18:30:00 10 1.3 13.3 7.2 9.8 1.3 13.3 6.8 32 6 35 305 1.5 0.4 2.2 -1.1 12/22/2005 18:40:00 10.9 1 13.3 8.4 10.6 1.1 13.7 7.6 33 6 36 305 1.8 0.1 2.2 1 12/22/2005 18:50:00 10.9 1.3 13.7 7.2 10.7 1.3 14.1 6.8 33 5 28 305 1.9 0.1 2.2 0.3 12/22/2005 19:00:00 10.8 1.2 13.7 8 10.6 1.3 13.7 8 31 6 29 305 1.7 0.2 2.2 0.3 12/22/2005 19:10:00 9.8 1.2 12.6 6.5 9.7 1.2 12.2 6.8 30 6 33 305 1.7 0.1 2.2 0.6 12/22/2005 19:20:00 10.3 1.3 14.1 7.2 10.3 1.3 14.1 7.6 35 6 37 305 1.6 0.2 2.2 0.1 12/22/2005 19:30:00 10.9 1.5 14.5 7.6 10.7 1.5 14.1 7.6 34 5 31 305 1.9 0.2 2.5 -0.4 12/22/2005 19:40:00 10.6 1.2 13.7 7.2 10.4 1.2 13 7.6 36 5 30 305 1.8 0.1 2.2 1 12/22/2005 19:50:00 10.5 1.2 13 7.2 10.4 1.3 13 7.2 37 5 31 305 1.9 0.1 2.2 0.8 12/22/2005 20:00:00 10.6 1.1 13.3 8.4 10.5 1.2 13.3 8 35 6 30 305 1.7 0.2 2.2 0.1 12/22/2005 20:10:00 10.4 1.1 13 7.6 10.3 1.2 13 6.5 35 6 35 305 1.6 0.2 2 0.3 12/22/2005 20:20:00 10.8 1.1 13.7 8 10.7 1.1 13.7 8.4 38 6 26 305 1.6 0.1 2 0.1 12/22/2005 20:30:00 11.5 1.3 14.1 7.2 11.4 1.5 14.5 6.8 39 6 41 305 1.7 0.3 2.2 0.6 12/22/2005 20:40:00 10.7 1.1 13.3 8 10.6 1.1 13.3 7.6 41 6 47 305 2 0.1 2.2 1.3 12/22/2005 20:50:00 10.7 1.2 13.3 7.6 10.7 1.2 13.3 8 38 6 47 305 2.2 0.1 2.5 1 12/22/2005 21:00:00 10 1.2 13.3 7.6 9.9 1.3 14.1 6.8 41 6 40 305 2 0.2 2.5 0.8 12/22/2005 21:10:00 10.6 1.1 13 7.2 10.5 1.2 13.3 7.2 38 6 41 305 2 0.1 2.5 1.5 12/22/2005 21:20:00 10.7 1.3 13.7 7.6 10.5 1.4 13.7 7.2 37 6 39 305 1.9 0.2 2.5 1.5 12/22/2005 21:30:00 10.4 1.1 13 8 10.2 1.2 13 7.6 38 6 42 305 2 0.1 2.5 1.7 12/22/2005 21:40:00 10 1.1 12.6 7.2 10 1.1 13 7.6 39 6 46 305 2.2 0.1 2.5 1.5 12/22/2005 21:50:00 9.1 0.8 11.1 6.8 9 1 11.5 6.5 42 6 40 305 2.2 0.2 2.5 0.8 12/22/2005 22:00:00 9.8 1.3 13 6.1 9.6 1.4 13 6.1 38 7 23 305 2.3 0.3 3.2 1.5 12/22/2005 22:10:00 10.5 1.2 13.7 7.6 10.3 1.3 13.7 8 37 7 38 305 2.3 0.3 3.2 1.5 12/22/2005 22:20:00 10.6 1.4 13.7 7.2 10.5 1.3 14.1 8 39 6 40 305 2.2 0.2 2.9 1.5 12/22/2005 22:30:00 11.3 1.2 14.1 8.4 11.2 1.2 14.1 7.6 40 6 35 305 2.1 0.1 2.9 1.5 12/22/2005 22:40:00 11.8 1.2 14.1 8.8 11.8 1.2 14.1 9.1 40 5 38 305 2.4 0.4 3.4 1.5 12/22/2005 22:50:00 10.4 1 13 8.4 10.4 1 13 8 39 6 38 305 2.3 0.1 2.7 2 12/22/2005 23:00:00 11.1 1.1 13.7 8.4 11.1 1.2 14.5 8 42 6 45 305 2.2 0.1 2.5 0.6 12/22/2005 23:10:00 11.5 0.9 13.7 8.4 11.4 1 13.7 8.4 44 5 40 305 2.2 0.1 2.5 0.6 12/22/2005 23:20:00 11.4 1.2 14.1 8.4 11.3 1.2 14.1 8.4 43 5 46 305 1.9 0.1 2.2 0.3 12/22/2005 23:30:00 12.2 1.1 14.9 9.5 12.2 1.1 14.5 9.1 43 6 40 305 1 0.8 2 -1.8 12/22/2005 23:40:00 11.9 1 14.5 9.1 11.8 1.1 14.1 9.1 44 5 45 305 1.6 1.3 4.4 -8.8 12/22/2005 23:50:00 11.7 1.2 14.5 8.8 11.5 1.2 14.1 8.4 44 5 42 305 3.6 1.1 4.9 -9.6 12/23/2005 00:00:00 11.9 1 14.1 9.1 11.8 1.1 14.5 8.4 43 5 42 305 3.8 0.1 4.2 2.2 12/23/2005 00:10:00 11.4 1 14.1 9.1 11.3 1.1 14.5 8.4 40 6 40 305 4 0.4 4.9 2 12/23/2005 00:20:00 11.6 1.2 14.1 8 11.5 1.4 14.5 8 44 5 37 305 4.8 0.4 6.4 2.9 12/23/2005 00:30:00 11.1 1.2 13.7 7.2 11 1.3 14.1 7.2 43 6 39 305 5.7 0.8 8.2 3.7 12/23/2005 00:40:00 10.9 1 13.3 7.6 10.7 1.1 13.3 8.4 43 5 40 305 8.2 0.3 8.9 7.7 12/23/2005 00:50:00 10.9 1.3 13.7 8 10.7 1.3 13.7 7.6 45 5 47 305 8.3 0.1 8.7 7.9 12/23/2005 01:00:00 10.8 1.1 14.5 8 10.6 1.1 13.7 7.6 43 6 47 305 7.7 0.4 8.4 7.2 12/23/2005 01:10:00 11.5 1.2 14.5 8.4 11.3 1.4 14.9 7.2 41 6 43 305 7.5 0 7.7 7.2 12/23/2005 01:20:00 12.3 1.1 14.9 9.9 12 1.2 15.3 9.1 40 5 36 305 7.3 0.1 8.2 7.2 12/23/2005 01:30:00 11.9 1.3 15.6 8.8 11.7 1.3 16.1 8.8 41 7 39 305 9.3 1.6 10.8 -2.9 12/23/2005 01:40:00 12.2 1.1 15.3 9.5 12 1.2 15.3 8.8 43 5 41 305 9.7 1 10.8 2.2 12/23/2005 01:50:00 11.7 1.4 15.3 8.4 11.6 1.4 15.3 8 43 6 40 305 10.6 0 10.8 10.5 12/23/2005 02:00:00 12.4 1.2 16.8 9.5 12.2 1.3 17.2 8.8 45 6 44 305 10.1 0.6 10.8 7.2 12/23/2005 02:10:00 13.3 1.2 16.4 10.3 13.2 1.3 16.1 10.3 46 6 47 305 9.3 1.2 10.8 7.2 12/23/2005 02:20:00 12.4 1.3 15.6 9.1 12.4 1.2 16.1 9.5 45 6 50 305 7.9 0.5 8.7 7.2 12/23/2005 02:30:00 11.7 1.1 14.5 9.1 11.6 1.1 14.5 8.8 48 6 46 305 8.2 0.3 8.7 7.2 12/23/2005 02:40:00 11.2 1.2 13.7 7.6 11 1.2 13.7 8 48 6 61 305 8.4 0.2 8.9 7.2 12/23/2005 02:50:00 11.7 1.1 14.5 8.8 11.4 1.2 14.9 8 47 6 43 305 8.1 0.5 8.9 7.2 12/23/2005 03:00:00 11.8 1 14.5 9.1 11.6 1.1 14.1 8.8 49 6 48 305 8.2 0.5 8.9 6.9 12/23/2005 03:10:00 10.3 1.2 13.7 7.2 10 1.2 13.7 6.8 46 6 50 305 8 0.5 8.7 7.2 12/23/2005 03:20:00 10.9 1.2 13.7 7.6 10.8 1.2 13.3 7.6 42 6 39 305 8.2 0.5 8.9 7.2 12/23/2005 03:30:00 12 1.3 15.6 8.8 11.7 1.3 14.1 8.8 41 6 39 305 8.6 0.2 8.9 7.4 12/23/2005 03:40:00 12.8 1 15.3 9.9 12.7 1.1 15.3 9.9 42 5 33 305 8.7 0 8.9 7.7 12/23/2005 03:50:00 12.5 1.3 16.4 9.1 12.3 1.3 15.6 9.1 42 6 39 305 8.5 0.3 8.9 7.2 12/23/2005 04:00:00 12.2 1.2 15.3 9.1 12.1 1.3 15.6 8.8 41 6 40 305 8 0.5 8.7 6.9 12/23/2005 04:10:00 12.2 1.2 15.3 9.5 12 1.3 15.6 8.8 42 5 51 305 7.2 0.4 7.7 6.4 12/23/2005 04:20:00 12.4 1.4 15.6 8.8 12.2 1.5 16.8 9.1 45 6 44 305 7.2 0.4 7.7 6.1 12/23/2005 04:30:00 12.7 1.1 15.3 10.3 12.6 1.2 15.3 9.9 46 5 40 305 7 0.2 7.7 5.9 12/23/2005 04:40:00 12.3 1.2 14.9 9.1 12.1 1.3 14.9 9.1 47 5 48 305 7 1.8 7.9 -2.2 12/23/2005 04:50:00 11.8 1.2 15.3 8.8 11.6 1.3 16.1 8.4 45 5 47 305 7.4 0.4 7.9 6.4 12/23/2005 05:00:00 12.1 1.2 14.9 9.1 11.8 1.2 14.5 8.8 45 6 37 305 7.4 0.4 7.9 6.9 12/23/2005 05:10:00 11.5 1.3 14.9 8.4 11.4 1.4 15.3 8 46 6 46 305 7.6 0.3 7.9 6.4 12/23/2005 05:20:00 12.5 1.4 16.1 8.8 12.4 1.5 16.1 9.1 45 6 45 305 8.2 0.3 8.4 6.9 12/23/2005 05:30:00 11.2 1.1 14.1 8.4 11.1 1.2 14.1 7.6 46 7 38 305 7.7 0.4 8.2 6.4 12/23/2005 05:40:00 11.9 1.3 14.9 8.8 11.7 1.3 15.3 8.4 41 6 42 305 7.9 0 8.2 7.7 12/23/2005 05:50:00 11.8 1.2 15.3 9.5 11.6 1.3 14.9 8.4 38 5 32 305 7.9 0 8.2 7.7 12/23/2005 06:00:00 11 1 13 8.4 10.7 1.1 13 8 41 6 36 305 7 0.8 8.2 0.1 12/23/2005 06:10:00 11.5 1.3 14.5 8.4 11.4 1.3 14.9 8.8 42 6 51 305 7 0.2 7.2 6.1 12/23/2005 06:20:00 11.8 1.3 15.3 9.1 11.7 1.4 15.3 8.8 41 6 40 305 6.6 0.5 7.2 5.6 12/23/2005 06:30:00 12.8 1 14.9 9.9 12.6 1.1 15.6 9.9 40 5 35 305 6.7 0.3 7.2 5.9 12/23/2005 06:40:00 12.7 1 14.9 9.9 12.6 1.1 14.9 9.1 40 5 40 305 6.6 0 6.9 6.4 12/23/2005 06:50:00 12.7 1 15.3 9.9 12.6 1.1 15.6 9.5 39 5 37 305 6.5 0 6.7 6.4 12/23/2005 07:00:00 12.7 1.3 15.3 9.1 12.5 1.4 15.6 8.8 37 5 40 305 6.4 0.3 6.7 5.4 12/23/2005 07:10:00 11.9 1.1 14.5 9.1 11.9 1.1 14.9 8.8 38 6 38 305 6.5 0 6.7 6.4 12/23/2005 07:20:00 10.4 1 13 7.6 10.3 1 12.6 7.6 39 6 39 305 8.1 2.7 11.8 5.4 12/23/2005 07:30:00 11.2 1.2 14.1 8.4 11.1 1.2 14.5 8 41 6 39 305 8.4 3.4 11.8 0.3 12/23/2005 07:40:00 12.6 1.1 15.3 8.4 12.4 1.3 15.6 9.5 40 6 42 305 7 1.8 10.2 2.7 12/23/2005 07:50:00 11.4 1.8 14.9 7.2 11.4 1.8 16.1 6.8 44 6 37 305 10 0.1 10.5 10 12/23/2005 08:00:00 11.4 1.2 14.5 8.8 11.3 1.3 14.1 7.6 37 5 40 305 10.2 0.1 10.5 9.5 12/23/2005 08:10:00 11.7 1.7 14.5 8.4 11.5 1.7 14.5 8 41 5 51 305 10 0.4 10.2 9.2 12/23/2005 08:20:00 12.5 1.1 14.9 9.5 12.4 1.2 14.9 8.8 40 5 37 305 9.9 0.4 10.2 9.2 12/23/2005 08:30:00 11.6 1.2 14.5 8.4 11.5 1.2 14.5 8.4 36 6 42 305 9.7 0.4 10.2 8.7 12/23/2005 08:40:00 11.8 1.3 14.9 8.8 11.6 1.5 14.9 8.4 37 6 33 305 9.9 0 10 9.5 12/23/2005 08:50:00 11.3 1.6 14.5 7.2 11.3 1.6 14.5 6.8 38 7 40 305 9.8 0 10 9.7 12/23/2005 09:00:00 11.8 1 14.5 9.1 11.6 1.1 14.5 8.4 36 6 31 305 9.9 0.6 12.1 8.9 12/23/2005 09:10:00 10.9 1.1 13.7 8.4 10.8 1.1 13.3 8 40 7 39 305 12.1 0 12.4 11.8 12/23/2005 09:20:00 10.7 1.4 14.5 7.6 10.6 1.4 14.1 7.6 40 7 36 305 11.8 0.6 12.1 9.5 12/23/2005 09:30:00 12.2 1 14.5 9.5 12 1.1 14.9 9.1 35 5 39 305 12.1 0 12.1 11.8 12/23/2005 09:40:00 11.1 1.5 14.9 7.6 11 1.5 14.5 7.2 36 6 35 305 12 0 12.1 11.8 12/23/2005 09:50:00 10.9 1.4 14.1 7.2 10.8 1.4 13.7 7.2 36 6 36 305 12.4 0.4 12.9 11.8 12/23/2005 10:00:00 12.6 1.2 14.9 8.4 12.3 1.2 14.9 8.8 32 4 29 305 12.7 0 12.9 12.6 12/23/2005 10:10:00 12.4 1.1 14.5 9.5 12.2 1.1 14.9 9.1 35 6 35 305 13 0 13.2 12.6 12/23/2005 10:20:00 12.2 1.5 15.6 8.8 12 1.7 15.6 8.8 43 6 39 305 13 0 13.2 12.9 12/23/2005 10:30:00 12.2 1.3 14.9 8.8 12.1 1.4 15.3 8.4 42 6 44 305 13 0 13.2 12.9 12/23/2005 10:40:00 12 1.5 15.6 8 12 1.5 15.6 7.6 46 6 48 305 12.2 0.2 12.9 11.3 12/23/2005 10:50:00 12.8 1.2 15.3 8.8 12.6 1.2 16.4 9.1 44 6 36 305 11.9 0.4 12.4 10.8 12/23/2005 11:00:00 12.2 1.4 14.9 8.8 12.1 1.5 15.6 8.8 46 5 50 305 12.5 0.6 13.2 11.3 12/23/2005 11:10:00 12.1 1.3 15.3 8.4 12 1.3 15.6 8.8 46 6 51 305 14.5 0.4 15.1 12.9 12/23/2005 11:20:00 12.3 1.2 14.9 8 12 1.3 15.3 9.1 36 6 39 305 14 0.5 14.5 12.9 12/23/2005 11:30:00 11.8 1.2 14.5 8.4 11.5 1.2 14.9 8 39 6 36 305 14.2 1.5 17.3 12.4 12/23/2005 11:40:00 12.2 1.4 16.1 8.4 12 1.5 15.6 8 40 6 37 305 17.8 0.4 18.4 15.9 12/23/2005 11:50:00 11.4 1.4 14.5 7.6 11.2 1.5 14.5 8 37 7 40 305 18.1 0.5 19 14 12/23/2005 12:00:00 11.8 1 14.1 9.5 11.6 1 14.9 9.1 38 6 44 305 18.3 0.5 19 14.3 12/23/2005 12:10:00 10.7 1.4 14.5 7.6 10.7 1.4 14.5 7.6 36 6 40 305 18.3 0.6 19.3 13.7 12/23/2005 12:20:00 11.4 1.4 15.3 8 11.3 1.5 14.9 8.4 39 6 48 305 20.1 0.9 21.3 17.3 12/23/2005 12:30:00 11.5 1.3 14.1 8.4 11.4 1.3 14.5 8.4 40 6 37 305 21.2 0.5 21.9 19.3 12/23/2005 12:40:00 10.6 1.3 13.3 7.2 10.5 1.3 13.3 7.2 41 6 37 305 21.4 0.2 21.9 20.7 12/23/2005 12:50:00 11 1.6 14.5 7.6 10.9 1.7 14.5 7.2 42 6 37 305 20.6 0 21 19.9 12/23/2005 13:00:00 10.7 1.3 14.5 8 10.6 1.3 14.1 7.6 40 7 39 305 20.9 0.4 21.6 19.6 12/23/2005 13:10:00 11.2 1.3 14.1 8.4 11 1.5 14.1 7.2 37 7 35 305 21.2 0.2 21.9 20.4 12/23/2005 13:20:00 12.6 1.2 15.6 8.4 12.4 1.3 16.1 8 40 7 44 305 21.4 0.2 21.9 20.7 12/23/2005 13:30:00 12.1 1.5 15.6 7.6 11.9 1.5 15.6 8 42 6 42 305 21.5 0.7 21.9 16.5 12/23/2005 13:40:00 11 1.5 14.5 7.2 10.8 1.5 13.7 7.2 43 6 46 305 22.6 0.6 23.4 21.3 12/23/2005 13:50:00 11.7 1.5 14.9 8 11.5 1.5 14.9 8 43 7 48 305 23.1 0 23.4 22.8 12/23/2005 14:00:00 12.6 1.3 16.1 8.8 12.4 1.3 15.6 8.8 44 6 43 305 22.6 0.4 23.1 21.3 12/23/2005 14:10:00 11.4 1.2 14.5 8 11.3 1.2 14.5 8 45 7 49 305 22.8 0.6 25.8 21.9 12/23/2005 14:20:00 12.2 1.3 15.3 9.1 12 1.4 14.9 8.8 43 7 41 305 20 2.1 23.1 16.2 12/23/2005 14:30:00 12.1 1.3 15.3 9.1 11.9 1.3 14.9 8.8 39 6 47 305 18.7 1.4 19.9 10.5 12/23/2005 14:40:00 12.6 1.2 15.6 8.8 12.3 1.2 15.3 9.1 42 6 35 305 19.5 1.8 21.9 11 12/23/2005 14:50:00 11.9 1.4 15.3 8.4 11.8 1.5 15.3 7.6 42 6 37 305 21.1 1 23.4 14 12/23/2005 15:00:00 11.5 1.3 15.6 8.8 11.3 1.4 15.3 8.4 38 7 29 305 20.9 1.4 22.2 11.8 12/23/2005 15:10:00 12.8 1.3 15.6 9.5 12.7 1.4 15.6 9.5 41 6 39 305 20.8 0.9 22.8 17.9 12/23/2005 15:20:00 12.4 1.3 15.6 9.5 12.3 1.3 15.3 9.5 43 6 40 305 21.4 0.6 22.8 19.9 12/23/2005 15:30:00 11.9 1.7 15.3 8.4 11.5 1.7 15.3 7.6 40 7 38 305 17.3 2.2 21.9 14.8 12/23/2005 15:40:00 11.1 1.7 14.9 7.2 10.9 1.7 14.5 6.8 42 7 39 305 15.7 2.2 19.9 10 12/23/2005 15:50:00 11.8 1.5 15.3 8.4 11.6 1.5 15.3 8.8 39 7 37 305 18.4 2 21 14.3 12/23/2005 16:00:00 11.8 2 16.4 7.2 11.6 2.1 16.4 7.2 39 6 48 305 19 0.5 20.4 17.3 12/23/2005 16:10:00 11.1 1.5 14.9 7.2 11 1.6 14.5 7.2 41 7 48 305 18.4 0.4 19.6 17 12/23/2005 16:20:00 11.5 1.4 15.6 8 11.2 1.5 14.9 7.2 43 7 37 305 18.2 0.4 19 16.7 12/23/2005 16:30:00 11.5 1.3 14.5 7.6 11.4 1.3 14.5 7.6 42 7 37 305 18.3 0.4 19.3 17 12/23/2005 16:40:00 11.8 1.5 14.9 7.6 11.6 1.5 15.3 7.6 44 6 36 305 18.7 0.4 19.6 17.6 12/23/2005 16:50:00 12.3 1.4 15.3 8.8 12.1 1.4 15.6 8.8 38 7 38 305 18.6 0.3 19.3 17.6 12/23/2005 17:00:00 12.2 1.5 15.6 8.4 11.9 1.6 15.3 7.6 41 6 37 305 18.1 0.2 18.4 17.3 12/23/2005 17:10:00 12.3 1.5 15.6 8.4 12.1 1.4 16.1 8.8 40 7 44 305 17.3 0 17.6 16.5 12/23/2005 17:20:00 11.9 2.2 16.4 6.8 11.8 2.2 16.1 6.8 42 6 46 305 15.6 0.8 17 14.3 12/23/2005 17:30:00 11.7 1.7 15.3 8 11.5 1.8 15.6 7.6 43 5 44 305 15.7 0.6 17 14.3 12/23/2005 17:40:00 12.3 1.3 15.3 8.8 12 1.5 15.3 8 40 6 37 305 16.5 0.3 17 15.6 12/23/2005 17:50:00 11.3 1.3 14.9 8.4 11.2 1.3 14.9 8.4 44 6 46 305 16.2 0 17 15.6 12/23/2005 18:00:00 12.4 1.4 16.1 9.1 12.2 1.5 16.1 9.1 42 6 33 305 16.2 0.1 16.5 15.6 12/23/2005 18:10:00 11.9 1.4 15.3 7.6 11.6 1.5 14.9 8 40 7 40 305 15.5 0.1 16.2 14.8 12/23/2005 18:20:00 12.3 1.1 14.1 8 12.1 1 15.3 9.5 41 6 40 305 15.4 0.3 16.5 14.8 12/23/2005 18:30:00 11.3 1.3 14.5 8.4 11.1 1.3 14.9 8 39 7 38 305 15.9 0.2 16.2 15.1 12/23/2005 18:40:00 11.5 1.3 14.5 7.6 11.2 1.4 13.7 7.2 41 7 40 305 16.7 0.2 17 15.9 12/23/2005 18:50:00 11.4 1.3 13.7 8 11.2 1.4 14.1 7.6 38 7 34 305 16.8 0 17 15.9 12/23/2005 19:00:00 11.7 1.3 14.9 8.4 11.5 1.4 15.3 8 38 6 39 305 16.5 0.1 16.7 15.9 12/23/2005 19:10:00 12.7 1 14.9 10.3 12.5 1 14.5 9.9 34 6 41 305 16.2 0.4 17 15.3 12/23/2005 19:20:00 12.4 1.2 15.6 9.5 12.2 1.3 15.6 9.1 33 6 27 305 14.9 0.5 15.6 14 12/23/2005 19:30:00 12.5 1.5 16.1 7.6 12.3 1.5 16.1 8 37 6 34 305 14.7 0.6 15.6 11.6 12/23/2005 19:40:00 12 1.6 16.8 8 11.9 1.6 16.4 7.2 37 6 40 305 15.5 0.2 16.2 14.8 12/23/2005 19:50:00 11.7 1.4 14.9 7.2 11.4 1.4 14.9 8.4 38 7 44 305 15.4 0.5 16.5 13.7 12/23/2005 20:00:00 11.6 1.7 15.3 8.4 11.4 1.6 14.9 7.6 42 7 35 305 16.2 0.2 16.7 15.1 12/23/2005 20:10:00 12.8 1.6 16.1 8.8 12.6 1.7 16.1 8.8 39 6 35 305 16.4 0.4 17.3 15.1 12/23/2005 20:20:00 13 1.3 16.1 10.3 13 1.4 15.6 9.5 42 6 37 305 16.7 0.2 17.3 15.9 12/23/2005 20:30:00 12.6 1.3 15.6 9.1 12.4 1.2 15.3 9.1 39 6 37 305 16.9 0.5 18.7 15.3 12/23/2005 20:40:00 13 1.5 16.1 8.8 12.8 1.7 16.8 8 45 6 40 305 18 0.5 19.9 16.7 12/23/2005 20:50:00 12.7 1.5 16.8 9.1 12.6 1.6 16.8 9.1 42 6 39 305 20.1 0 20.1 19.3 12/23/2005 21:00:00 13.6 1.5 17.6 9.1 13.5 1.7 17.9 9.5 41 6 43 305 19.9 0 20.1 19.3 12/23/2005 21:10:00 13.5 1.3 17.2 9.9 13.3 1.4 16.4 10.3 42 6 52 305 19.9 0 20.1 19.3 12/23/2005 21:20:00 13.1 1.5 17.2 9.5 12.8 1.6 16.8 9.1 38 6 39 305 20 0.2 20.4 19.3 12/23/2005 21:30:00 11.7 1.5 14.9 8.4 11.4 1.5 15.3 7.2 36 6 34 305 19.7 0.3 20.4 18.7 12/23/2005 21:40:00 12.2 1.6 15.6 8.4 12.1 1.7 16.1 8.4 37 7 40 305 20 0.2 20.7 19.6 12/23/2005 21:50:00 13.3 1.4 16.4 7.6 13 1.5 16.1 7.2 38 6 36 305 20.5 0.1 20.7 19.9 12/23/2005 22:00:00 12.4 1.3 15.6 8.8 12.2 1.3 16.1 8.8 38 6 42 305 20.6 0.2 21.3 19.9 12/23/2005 22:10:00 12.5 1.4 15.6 8.8 12.3 1.4 15.3 8.8 38 6 37 305 21.3 0.9 22.8 20.1 12/23/2005 22:20:00 12.3 1.4 16.1 8.8 12.1 1.5 15.3 8.4 41 6 43 305 22.7 0.2 23.7 21.6 12/23/2005 22:30:00 11.7 1.5 15.6 7.6 11.6 1.5 15.3 7.6 42 7 48 305 23.2 0.2 24 22.2 12/23/2005 22:40:00 10.5 1.6 14.1 7.2 10.3 1.6 14.5 6.8 38 7 49 305 23.5 0.3 24.6 22.2 12/23/2005 22:50:00 11.2 1.5 14.9 8 11 1.5 14.1 7.2 38 6 28 305 23.8 0 24.3 22.8 12/23/2005 23:00:00 11.4 1.2 14.9 8 11.3 1.2 14.5 7.6 37 6 45 305 23.4 0.7 24.9 20.4 12/23/2005 23:10:00 10.5 1.4 13.7 6.8 10.3 1.4 13.7 7.2 36 6 32 305 24.3 1.1 26.1 21.9 12/23/2005 23:20:00 11.1 1 14.1 9.1 11 1 13.7 8.4 36 6 25 305 23.5 0.7 25.2 21.6 12/23/2005 23:30:00 10.8 1.3 13.3 7.6 10.8 1.3 13.7 8 34 7 34 305 24 1 26.7 21.9 12/23/2005 23:40:00 10.3 1.1 13 7.6 10.2 1.1 13 7.2 38 7 37 305 25.2 0.6 26.1 23.7 12/23/2005 23:50:00 10.8 1.1 13.7 8 10.6 1.1 13.7 7.6 38 7 41 305 24.3 0.6 25.5 22.5 12/24/2005 00:00:00 10.3 1.2 13.3 7.6 10.2 1.3 13.3 7.2 35 6 38 305 24.5 1.2 25.8 20.1 12/24/2005 00:10:00 10.6 1.3 13.7 7.6 10.5 1.4 14.1 7.2 35 6 41 305 25.2 0.6 26.7 23.7 12/24/2005 00:20:00 11 1.3 13.7 8 10.9 1.3 14.1 7.2 36 6 25 305 25.2 0.5 26.4 24 12/24/2005 00:30:00 10.6 1.3 13.7 8 10.6 1.3 14.1 7.6 35 6 34 305 25.4 0.6 26.4 23.7 12/24/2005 00:40:00 11.4 1.5 14.9 7.6 11.2 1.4 14.1 7.2 34 6 37 305 24.7 0.6 26.4 22.8 12/24/2005 00:50:00 12 1 14.5 9.1 11.7 1.1 14.1 9.1 36 5 33 305 24.8 0.5 26.1 23.1 12/24/2005 01:00:00 11.8 1.3 14.9 8.8 11.7 1.3 14.9 8.4 35 6 33 305 25.4 0.7 26.7 22.2 12/24/2005 01:10:00 12.3 1.1 14.9 9.5 12.1 1.1 15.3 9.5 34 6 37 305 25.6 0.2 26.1 24.9 12/24/2005 01:20:00 12.8 1 15.6 10.3 12.8 1.1 15.6 9.9 36 5 34 305 24.9 0.6 26.4 23.4 12/24/2005 01:30:00 12.7 1.3 15.6 9.1 12.6 1.3 15.6 9.1 35 5 22 305 24.9 0.6 26.1 23.4 12/24/2005 01:40:00 12.2 1.5 15.3 8 12.1 1.5 16.1 8 36 6 32 305 25.2 0.8 26.7 22.8 12/24/2005 01:50:00 13.5 1.1 16.4 9.9 13.3 1.2 16.4 9.9 36 5 39 305 25.2 0.5 26.7 24 12/24/2005 02:00:00 12.9 1.2 15.3 9.9 12.8 1.2 15.6 9.9 37 5 32 305 25.7 0.6 27 24 12/24/2005 02:10:00 12.6 1.2 15.3 9.5 12.6 1.3 15.6 9.9 37 5 38 305 25.4 0.3 27 24 12/24/2005 02:20:00 12 1.7 15.3 8.4 11.9 1.7 16.1 8 36 6 31 305 26.7 0 27 26.7 12/24/2005 02:30:00 12.4 1.2 14.9 9.1 12.4 1.2 15.3 9.5 36 5 37 305 27.7 0.7 28.5 26.1 12/24/2005 02:40:00 12.6 1.2 15.3 9.1 12.5 1.2 15.6 8.8 36 6 34 305 27.8 0.5 28.5 26.4 12/24/2005 02:50:00 12.3 1.2 15.3 9.9 12.3 1.2 15.6 9.9 35 5 29 305 27.4 0.6 28.2 25.5 12/24/2005 03:00:00 12.4 1.4 15.3 9.1 12.2 1.4 15.3 8.8 35 5 37 305 27.4 0.4 27.6 25.8 12/24/2005 03:10:00 11.9 1.2 15.3 9.1 11.8 1.2 14.5 8.8 35 6 32 305 27.3 1 28.2 22.2 12/24/2005 03:20:00 11.8 1.3 14.5 8 11.8 1.3 14.5 8.8 35 5 45 305 27.8 0 27.9 27.6 12/24/2005 03:30:00 11.6 1.3 14.9 8.8 11.5 1.3 14.5 8.4 33 6 32 305 27.4 0.3 27.9 23.7 12/24/2005 03:40:00 11.3 1.7 14.5 8 11.3 1.7 14.5 7.2 35 5 42 305 25.4 1.8 27.9 21.9 12/24/2005 03:50:00 10.7 1.2 14.5 8 10.8 1.1 14.5 7.6 35 6 32 305 23.2 0.8 26.4 22.2 12/24/2005 04:00:00 11.8 1.1 14.5 8.4 11.7 1.2 14.5 8.4 34 5 33 305 23.7 0.6 25.5 23.1 12/24/2005 04:10:00 11 1.2 14.1 8 10.9 1.2 14.5 7.6 33 6 40 305 24.4 0.4 25.5 23.7 12/24/2005 04:20:00 11.6 1.2 14.9 8.4 11.2 1.1 14.5 8.4 34 6 35 305 23.6 0.4 24.9 22.8 12/24/2005 04:30:00 11.8 1.1 15.3 9.5 11.6 1.2 14.9 8.8 34 6 25 305 22.5 0.3 23.7 21.9 12/24/2005 04:40:00 12.8 1.3 15.6 9.5 12.5 1.3 15.3 9.1 34 5 28 305 24.8 1.5 26.4 21.9 12/24/2005 04:50:00 12.6 1.1 15.6 9.1 12.4 1.2 15.3 9.1 36 6 35 305 22.3 1.2 25.8 20.7 12/24/2005 05:00:00 12.4 1.2 15.6 9.5 12.3 1.2 15.3 9.1 37 5 46 305 24.7 1.4 27 21 12/24/2005 05:10:00 11.5 1.1 14.1 9.1 11.3 1.1 14.1 9.1 37 6 45 305 24.3 1.7 26.7 20.7 12/24/2005 05:20:00 11.7 1.1 14.5 9.1 11.5 1.1 14.1 8.8 35 6 23 305 24.5 1.6 26.7 21.3 12/24/2005 05:30:00 10.9 1.3 14.5 8 10.8 1.3 14.5 8 34 6 33 305 22 0.5 25.5 20.7 12/24/2005 05:40:00 11.8 1.3 14.1 8.8 11.6 1.3 14.5 8.4 33 5 33 305 24.9 1.7 26.4 21.6 12/24/2005 05:50:00 11.6 1.1 14.5 9.1 11.5 1.1 14.5 8.8 33 6 34 305 22.1 1 26.1 21 12/24/2005 06:00:00 11 1.2 14.1 8.4 10.9 1.1 14.1 8.8 33 5 28 305 24.3 1.7 26.7 22.2 12/24/2005 06:10:00 11 1.5 14.9 7.2 10.8 1.5 14.9 8 32 6 32 305 25.7 0.5 26.4 22.2 12/24/2005 06:20:00 11.3 1.3 14.5 8 11.2 1.3 14.1 7.6 32 6 33 305 25.5 0.1 25.8 24.3 12/24/2005 06:30:00 11.7 1.6 16.1 7.6 11.7 1.6 16.1 7.6 33 7 35 305 25.4 0 26.4 24.9 12/24/2005 06:40:00 11 1.3 14.1 7.6 10.9 1.3 14.9 8 33 6 35 305 25.4 0.4 26.4 24 12/24/2005 06:50:00 11.9 1.5 15.3 8.4 11.7 1.5 15.6 8.4 35 6 33 305 23.7 1.8 25.8 21.3 12/24/2005 07:00:00 11.3 1.6 15.3 8 11.2 1.6 15.3 7.6 34 7 35 305 21.4 0.2 21.9 21 12/24/2005 07:10:00 11.7 1.3 14.9 8.4 11.5 1.2 14.9 8 33 6 23 305 21.7 0.6 24.9 20.7 12/24/2005 07:20:00 11.9 1.4 14.9 8.4 11.7 1.3 14.9 8.8 33 5 32 305 22.9 1.1 24 20.4 12/24/2005 07:30:00 12.1 1.4 14.9 9.1 11.9 1.3 14.9 8.8 33 6 37 305 22.5 0.8 23.7 19.6 12/24/2005 07:40:00 13.5 1.2 16.4 10.3 13.3 1.3 16.4 9.5 36 5 35 305 21.7 0.6 22.8 20.1 12/24/2005 07:50:00 13.5 1.2 16.4 10.3 13.4 1.2 16.1 9.1 35 5 33 305 23.5 1.6 25.5 20.1 12/24/2005 08:00:00 13.8 1.2 16.8 11.1 13.6 1.3 16.4 10.7 34 5 36 305 22.3 1.3 24.9 19 12/24/2005 08:10:00 13 1.2 15.6 10.3 12.9 1.2 15.3 9.9 35 5 33 305 21.9 0.7 23.1 19.3 12/24/2005 08:20:00 12 1.3 15.3 9.1 11.8 1.3 14.5 8.8 34 6 32 305 22.6 1.3 23.7 19.9 12/24/2005 08:30:00 12.5 1.5 16.1 8.4 12.3 1.5 16.1 9.1 36 6 36 305 20.1 0.8 23.4 19.3 12/24/2005 08:40:00 11.5 1.6 15.3 7.2 11.4 1.7 15.6 7.6 36 7 40 305 21.4 1.4 22.8 19 12/24/2005 08:50:00 11.7 1.3 15.3 8 11.4 1.4 15.3 8 35 6 32 305 22.5 0.4 23.1 20.7 12/24/2005 09:00:00 11.6 1.3 14.1 8 11.4 1.3 14.9 8 33 6 36 305 22.5 0.3 22.8 20.1 12/24/2005 09:10:00 12.4 1.3 16.1 9.5 12.2 1.3 16.1 8.4 32 6 29 305 22.5 0.1 22.8 21.9 12/24/2005 09:20:00 12.2 1.2 16.1 9.1 12.1 1.3 15.3 9.1 32 6 27 305 23 0.6 24.6 21.3 12/24/2005 09:30:00 12.2 1.2 14.9 9.1 12 1.2 14.9 9.1 31 6 25 305 23.4 0.2 24.3 22.5 12/24/2005 09:40:00 11.9 1 14.5 9.5 11.7 1 14.1 8.8 34 6 29 305 24.1 0.4 24.9 22.8 12/24/2005 09:50:00 12.8 1.2 15.3 9.5 12.5 1.3 15.3 9.5 34 5 35 305 23.7 0.5 24.3 21.3 12/24/2005 10:00:00 12.5 1.3 15.6 9.5 12.2 1.2 15.6 9.1 32 5 32 305 24.3 0.5 24.9 21.6 12/24/2005 10:10:00 12.5 1.2 15.6 9.1 12.3 1.2 15.3 9.5 31 5 22 305 22.8 1.7 24.6 17.9 12/24/2005 10:20:00 12.2 1.2 16.1 9.5 12.2 1.1 15.3 9.5 31 6 27 305 19.7 1 21 17.6 12/24/2005 10:30:00 12.6 1.1 15.3 9.9 12.4 1.1 15.6 9.1 34 6 37 305 18.8 0.3 19.6 17.9 12/24/2005 10:40:00 13 1.2 16.1 10.3 12.8 1.2 16.4 9.9 34 5 39 305 18.8 0.9 21.6 17.9 12/24/2005 10:50:00 13.5 1.1 16.1 10.7 13.3 1.1 16.1 10.3 36 6 32 305 20.5 1.4 23.4 17.9 12/24/2005 11:00:00 14.4 1.2 17.2 11.5 14.4 1.2 16.8 11.1 42 5 40 305 20.3 1.2 23.1 17.9 12/24/2005 11:10:00 14.1 1.1 16.8 11.5 14 1.2 16.8 11.1 40 5 46 305 21.7 1 22.8 19 12/24/2005 11:20:00 13.7 1.1 16.4 10.3 13.7 1.1 16.4 10.3 38 5 39 305 19.2 0.3 20.1 18.1 12/24/2005 11:30:00 14.9 1.2 17.9 11.5 14.6 1.2 17.2 11.5 39 5 45 305 19.3 0 19.6 19.3 12/24/2005 11:40:00 13.8 1.3 17.2 10.3 13.8 1.3 17.2 10.3 37 5 37 305 21.6 1.1 22.5 19 12/24/2005 11:50:00 12.9 1.1 15.6 10.3 12.7 1.2 15.6 9.9 35 5 32 305 22.3 2.1 27.3 14.3 12/24/2005 12:00:00 13.9 1.5 17.6 10.7 13.7 1.5 17.6 10.3 37 5 35 305 27.8 0.6 28.5 24.3 12/24/2005 12:10:00 13.9 1.4 17.6 11.1 13.8 1.4 17.2 11.1 36 5 35 305 28.5 0.9 29.2 25.5 12/24/2005 12:20:00 14.1 1.2 17.6 11.1 14 1.2 17.2 11.1 37 5 33 305 26.2 0.2 27 25.5 12/24/2005 12:30:00 13.6 1.2 16.4 10.3 13.4 1.3 16.4 9.9 38 6 37 305 26.8 0.4 27.6 26.1 12/24/2005 12:40:00 14.7 1.1 17.2 11.1 14.5 1.1 17.2 10.7 39 5 37 305 26.7 0.2 27.6 26.4 12/24/2005 12:50:00 14.4 1.3 17.2 10.3 14.3 1.3 16.8 9.9 38 5 37 305 26.8 0 27.3 26.7 12/24/2005 13:00:00 15 1 17.2 11.1 14.8 1.1 17.2 11.1 37 5 37 305 27.3 0.4 30.4 26.4 12/24/2005 13:10:00 15.1 1.1 17.9 11.8 14.9 1.1 16.8 12.2 37 4 30 305 27.4 0.2 28.2 26.7 12/24/2005 13:20:00 13.6 1.3 17.2 10.7 13.4 1.3 16.4 10.7 39 5 44 305 27.4 1.3 28.5 24.3 12/24/2005 13:30:00 13.7 1.2 16.8 9.9 13.6 1.3 16.4 10.3 39 5 35 305 27.9 1 31.4 24.9 12/24/2005 13:40:00 14.1 1.2 16.8 10.7 13.9 1.3 16.8 10.7 40 6 42 305 26.2 1.4 28.8 24 12/24/2005 13:50:00 13.3 1.1 15.6 9.9 13.1 1.1 15.6 9.9 39 5 40 305 28.5 0.7 29.2 25.2 12/24/2005 14:00:00 13.1 1.1 15.6 9.9 12.9 1.2 16.1 9.9 40 5 42 305 28.1 0.6 29.8 25.2 12/24/2005 14:10:00 12.2 1.1 14.9 9.5 12 1.1 15.3 9.1 40 5 40 305 28.3 0.7 29.5 25.5 12/24/2005 14:20:00 12.1 1 14.5 9.1 11.9 1 14.1 9.1 41 5 33 305 26 2 29.5 17 12/24/2005 14:30:00 12.6 1.2 16.1 9.9 12.3 1.3 15.3 9.1 40 5 38 305 27.9 1.8 30.7 24.3 12/24/2005 14:40:00 13.5 1.3 16.8 9.5 13.3 1.2 16.4 10.3 42 5 46 305 30.4 0.4 30.7 27.3 12/24/2005 14:50:00 12.7 1.1 16.4 10.3 12.4 1.1 15.6 9.5 42 5 40 305 30.5 0.3 30.7 27.9 12/24/2005 15:00:00 11.7 1.1 14.5 9.1 11.5 1.1 14.9 8.4 42 5 46 305 30.5 0 30.7 30.4 12/24/2005 15:10:00 12.4 1.1 16.1 9.9 12.2 1.2 15.3 9.1 41 5 38 305 29.3 1.7 30.7 26.4 12/24/2005 15:20:00 11.1 1 14.1 8.8 10.9 1 14.1 8.8 40 5 39 305 27.4 0.3 27.6 26.1 12/24/2005 15:30:00 10.7 1 13.3 8.4 10.6 1 13 8.4 42 5 40 305 26.8 0.6 27.6 22.5 12/24/2005 15:40:00 11.2 1.1 14.1 8.4 11 1.1 14.1 8.4 40 5 35 305 27.3 0.6 28.2 24.9 12/24/2005 15:50:00 11.8 1.1 14.9 9.1 11.4 1.2 14.5 8.8 38 5 33 305 27 1.5 28.5 23.4 12/24/2005 16:00:00 11.7 1.2 15.3 9.1 11.5 1.3 15.3 8.4 37 6 35 305 25.5 1.4 28.8 23.7 12/24/2005 16:10:00 12.5 1 15.3 10.3 12.4 1 15.6 9.1 42 6 40 305 26 0.9 27 24 12/24/2005 16:20:00 11.3 1 14.1 8.4 11.1 1.1 14.1 8.4 42 6 45 305 27.3 0.4 27.9 26.4 12/24/2005 16:30:00 11.6 1.4 14.5 8.4 11.4 1.5 14.5 8 38 5 40 305 26.8 0.2 27.9 26.4 12/24/2005 16:40:00 10.5 1 13.3 8.4 10.3 1.1 13 8 37 6 34 305 27.5 0.4 28.2 26.7 12/24/2005 16:50:00 10.5 0.9 13 8 10.4 1 12.6 8 35 6 39 305 27.6 0.4 28.2 26.7 12/24/2005 17:00:00 10.8 1.1 13.7 8 10.6 1.2 14.1 7.6 37 6 35 305 30.1 2.1 33.3 27.3 12/24/2005 17:10:00 11.2 1.2 14.5 8 11 1.2 14.5 8.4 40 6 46 305 32.5 0.2 33.3 31.7 12/24/2005 17:20:00 10.8 1 13.7 8.8 10.6 1 14.1 8 40 6 35 305 32 0 32.3 31.7 12/24/2005 17:30:00 10.6 1.1 14.1 8 10.4 1.2 13.3 7.2 40 6 34 305 31.8 0.7 32 27.6 12/24/2005 17:40:00 10.7 1.2 14.1 8 10.4 1.3 13.3 7.6 39 5 33 305 32.6 0.8 33.6 30.7 12/24/2005 17:50:00 10.4 1.1 13 7.6 10.2 1.2 13 7.6 40 5 38 305 32.2 0.2 33 31.7 12/24/2005 18:00:00 10.7 1.2 14.1 8 10.6 1.2 14.1 8 42 6 46 305 32.6 0 33 32.3 12/24/2005 18:10:00 10.7 1.2 13.7 7.6 10.6 1.2 13.7 7.6 41 6 40 305 32.3 0.2 32.6 31.4 12/24/2005 18:20:00 9.7 1 13 7.2 9.5 1.1 13 7.2 37 6 32 305 32.3 0.5 33.9 31.7 12/24/2005 18:30:00 10.2 0.9 12.6 8 10 0.8 12.6 8 39 6 38 305 29.9 2 33.3 25.8 12/24/2005 18:40:00 10 1.1 13 7.2 9.9 1.2 12.6 7.2 39 5 38 305 28.9 0.3 29.8 27.6 12/24/2005 18:50:00 11 1.5 14.5 7.2 10.9 1.5 14.5 7.2 38 6 41 305 29.2 0.5 30.4 28.2 12/24/2005 19:00:00 10.5 1.2 13.3 7.6 10.3 1.2 13.3 7.2 38 6 26 305 28.4 0.6 30.1 27.6 12/24/2005 19:10:00 10.2 1.1 13.7 7.2 10 1 13.3 7.6 36 6 19 305 28.7 0.6 30.1 27.3 12/24/2005 19:20:00 9.9 1.1 13 6.8 9.7 1.2 13 6.8 33 6 34 305 29.8 1 32.6 28.2 12/24/2005 19:30:00 8.7 1 11.1 6.8 8.6 1 10.7 6.5 32 6 30 305 29 0.6 30.1 27.3 12/24/2005 19:40:00 8.8 1 11.5 6.5 8.5 1 11.1 6.5 31 5 29 305 26.4 0.8 29.8 24.9 12/24/2005 19:50:00 9 1 11.8 6.5 8.7 1 11.5 6.5 35 6 32 305 27.3 1.4 28.8 24.3 12/24/2005 20:00:00 9.1 1.1 11.5 6.8 8.8 1 11.1 6.5 32 6 33 305 28.6 0 28.8 28.2 12/24/2005 20:10:00 9.5 1.1 12.6 6.8 9.3 1.1 12.6 6.8 33 5 31 305 29 0.9 30.1 23.7 12/24/2005 20:20:00 9.3 1 11.8 7.2 9 0.9 11.5 6.8 35 6 34 305 29.8 1.4 34.3 27.6 12/24/2005 20:30:00 8.6 0.9 11.1 6.1 8.4 0.8 10.7 5.7 35 6 41 305 34.3 0.2 34.6 33.6 12/24/2005 20:40:00 8.6 0.8 11.1 6.8 8.4 0.9 11.1 6.5 36 5 41 305 34.2 0 34.6 33.6 12/24/2005 20:50:00 8.9 0.8 11.1 6.8 8.7 0.8 11.1 6.5 33 6 38 305 33.4 1.4 34.6 27.3 12/24/2005 21:00:00 8.8 0.8 11.5 6.8 8.7 0.8 11.1 6.5 33 6 44 305 35.5 1.6 37.6 33.3 12/24/2005 21:10:00 8.9 1 11.8 6.8 8.7 1 11.8 6.5 35 6 34 305 37.4 1.1 39.3 33.6 12/24/2005 21:20:00 8 0.8 9.9 6.1 7.8 0.8 9.9 5.7 33 6 36 305 37.9 1.3 39.3 34.3 12/24/2005 21:30:00 7.7 0.8 9.9 5.7 7.6 0.8 9.5 5.7 27 5 24 305 38 0.8 39.6 32.6 12/24/2005 21:40:00 7.8 0.8 9.9 6.1 7.7 0.7 9.5 5.7 25 6 21 305 37.7 1.4 39.6 34.3 12/24/2005 21:50:00 8.9 1 11.8 6.5 8.7 1 11.1 6.8 23 5 18 305 38.1 1.5 40 34.9 12/24/2005 22:00:00 8.4 0.9 10.7 6.5 8.2 1 10.7 6.5 25 5 24 305 39.1 0.7 39.6 35.9 12/24/2005 22:10:00 8.2 1 10.7 5.7 8.1 1 10.7 4.9 26 6 27 305 38.8 0.4 39.3 36.2 12/24/2005 22:20:00 8.3 0.9 10.7 5.7 8.1 0.9 10.7 5.7 26 6 27 305 37.7 1.1 39.3 33 12/24/2005 22:30:00 7.9 0.9 10.3 5.7 7.8 1 10.3 6.1 26 6 25 305 36.6 1.5 38.3 33.3 12/24/2005 22:40:00 7.3 0.7 9.5 5.7 7.3 0.7 9.5 5.7 20 5 16 305 37.3 0.8 38.3 32.6 12/24/2005 22:50:00 9.1 0.9 11.1 6.8 9.1 1 11.5 6.5 20 5 18 305 37.5 0.8 38.6 33.3 12/24/2005 23:00:00 9.2 1.1 12.6 6.5 9.1 1.2 12.2 6.5 22 6 19 305 35.8 1.4 37.6 32.3 12/24/2005 23:10:00 9.5 0.9 11.5 7.2 9.3 1 11.8 6.8 22 5 27 305 36.2 1.1 37.6 32.6 12/24/2005 23:20:00 8.7 1 11.1 6.1 8.6 1 11.1 5.7 24 5 30 305 37 1.4 37.9 32.3 12/24/2005 23:30:00 8.5 0.9 10.3 6.5 8.3 1 10.7 6.1 23 6 19 305 37.2 0.2 37.9 36.6 12/24/2005 23:40:00 9 0.9 11.1 6.8 8.9 1 11.5 6.1 22 5 29 305 37.6 0.3 38.6 36.6 12/24/2005 23:50:00 9.2 1 11.5 6.8 9 1.1 11.8 6.5 20 5 21 305 36.8 1.2 38.6 33 12/25/2005 00:00:00 9.5 0.9 11.5 7.2 9.5 0.9 11.5 7.2 20 4 16 305 35.9 1.6 38.6 32.3 12/25/2005 00:10:00 9 1 11.5 6.5 8.8 1.2 11.8 5.7 19 6 20 305 35.4 1.4 37.2 33 12/25/2005 00:20:00 9.4 1 11.8 6.8 9.1 1.1 11.5 6.1 19 6 24 305 35.7 1.4 37.6 33.3 12/25/2005 00:30:00 8.9 1 11.1 6.1 8.9 1 11.5 6.5 19 6 15 305 37 1.1 38.3 33 12/25/2005 00:40:00 9.5 1.2 12.6 6.8 9.4 1.2 12.2 6.8 20 6 11 305 38 0 38.6 37.6 12/25/2005 00:50:00 9.8 0.9 12.2 7.2 9.6 0.9 11.8 6.8 22 5 15 305 37.1 1.4 37.9 32.6 12/25/2005 01:00:00 9.9 1.1 13 7.2 9.6 1.2 13.3 6.8 22 5 13 305 36.7 0.7 37.6 33 12/25/2005 01:10:00 9.4 1.2 13 6.5 9.3 1.2 12.6 5.7 21 6 18 305 36.2 1.1 37.2 31.7 12/25/2005 01:20:00 9.1 1 11.8 6.5 8.9 1 11.5 6.1 22 6 15 305 34.6 1.5 37.2 31 12/25/2005 01:30:00 9.7 0.9 12.2 6.8 9.4 1 12.2 6.8 23 6 15 305 33.9 1.7 37.2 28.5 12/25/2005 01:40:00 9 0.9 11.8 6.5 8.9 0.9 11.8 6.5 22 5 25 305 36.6 0.3 37.6 35.6 12/25/2005 01:50:00 9.7 1 11.8 6.8 9.5 1 11.8 6.8 19 5 25 305 34.8 1.7 37.2 31 12/25/2005 02:00:00 9.6 1.1 12.2 6.8 9.5 1.2 13 7.2 18 6 7 305 34.9 1.4 36.9 31 12/25/2005 02:10:00 11.1 1.3 14.5 7.6 10.9 1.3 14.9 8 20 5 17 305 35.7 1.6 37.2 31 12/25/2005 02:20:00 10.1 1.2 12.6 7.2 9.9 1.1 12.6 7.2 21 6 16 305 36.1 0.4 37.2 34.3 12/25/2005 02:30:00 10.8 1.3 13.3 7.6 10.7 1.3 13.7 7.6 21 6 22 305 36 0.3 36.9 35.3 12/25/2005 02:40:00 10.5 1.3 13.7 6.8 10.4 1.2 13.3 7.2 20 5 16 305 34.6 1.5 36.9 32.6 12/25/2005 02:50:00 10.5 1.1 13.3 7.6 10.3 1.2 13 7.2 20 6 18 305 36.8 0 37.6 36.2 12/25/2005 03:00:00 10.4 1.3 13 7.6 10.2 1.3 13.3 7.2 21 6 19 305 37.1 0 37.6 36.9 12/25/2005 03:10:00 10.7 1.2 14.1 7.2 10.5 1.2 13.3 6.8 21 6 16 305 32.6 3.8 37.2 24.3 12/25/2005 03:20:00 9.9 1.1 13 7.2 9.8 1.2 13 7.2 17 6 15 305 30.1 1.9 32.6 27.3 12/25/2005 03:30:00 10.4 1 13 8 10.2 1.1 12.6 8 18 6 14 305 31 2.4 36.6 26.1 12/25/2005 03:40:00 10.3 1.1 13.3 8 10.2 1.1 13.3 7.6 19 6 15 305 36.2 1.2 38.6 33.9 12/25/2005 03:50:00 10.9 1.3 13.7 7.2 10.8 1.2 14.1 7.6 18 5 14 305 38.3 0.1 38.6 36.6 12/25/2005 04:00:00 10.5 1.1 14.1 8 10.4 1.2 13.7 7.6 18 5 7 305 36.6 1.6 38.6 33.6 12/25/2005 04:10:00 10.5 1.2 13 7.6 10.4 1.3 13.3 6.5 20 6 25 305 37.8 1.1 38.9 33.3 12/25/2005 04:20:00 10.7 1 13.3 8.4 10.6 1 13 8 19 6 13 305 37.5 1.8 39.3 33.9 12/25/2005 04:30:00 11.2 1.5 14.1 6.8 11.2 1.3 13.7 7.2 17 6 12 305 37.7 1.3 38.9 34.6 12/25/2005 04:40:00 11.1 1.2 14.1 8.4 11.1 1.1 13.7 8.4 17 5 26 305 38 0 38.6 37.6 12/25/2005 04:50:00 12.1 1.3 15.3 8.8 12.1 1.2 14.5 8.4 14 5 13 305 38.5 0.3 38.9 37.9 12/25/2005 05:00:00 12.5 1.1 14.5 8.8 12.3 1.1 14.9 9.1 14 5 12 305 38.1 1.2 38.9 33.3 12/25/2005 05:10:00 11.7 1.2 14.9 8.4 11.6 1.2 14.9 8 17 5 16 305 38.1 1.3 38.9 34.3 12/25/2005 05:20:00 11.2 1.4 14.1 7.6 11 1.3 14.5 7.6 14 6 7 305 36.9 1.4 38.9 34.9 12/25/2005 05:30:00 11 1.1 14.1 8 10.8 1.2 14.1 8 17 5 23 305 37.8 1.5 39.3 35.3 12/25/2005 05:40:00 10.9 1.7 14.5 6.5 10.9 1.7 14.9 6.5 17 6 19 305 38.9 0 39.3 38.6 12/25/2005 05:50:00 10.8 1.3 13.7 7.2 10.6 1.4 14.1 6.8 15 6 14 305 38.9 0 39.3 38.6 12/25/2005 06:00:00 10.3 1.3 13.3 7.2 10.1 1.2 13 6.8 17 6 15 305 39 0 39.3 38.6 12/25/2005 06:10:00 10.8 1.4 14.9 7.6 10.7 1.3 14.1 7.6 17 6 14 305 39.2 0 39.6 38.6 12/25/2005 06:20:00 10.9 1.2 13.3 7.6 10.7 1.3 14.1 8 16 5 15 305 39.4 0 39.6 38.9 12/25/2005 06:30:00 9.9 1.2 13 7.2 9.9 1.1 12.6 6.8 16 6 25 305 39.4 0 39.6 38.9 12/25/2005 06:40:00 10.4 1.3 13.3 7.6 10.4 1.4 13.7 7.2 18 6 18 305 39.6 0.3 40.3 38.6 12/25/2005 06:50:00 10.5 1 13 8 10.5 1.1 13.7 7.2 17 5 10 305 39.8 0.1 40.3 39.3 12/25/2005 07:00:00 10.2 1.3 13.7 7.2 10.1 1.4 13.3 6.8 18 6 10 305 39.4 0 40 38.9 12/25/2005 07:10:00 10.6 1.1 13.7 7.2 10.4 1.2 13.3 6.8 19 5 12 305 39.3 0 39.6 38.9 12/25/2005 07:20:00 10.7 1.3 14.1 7.6 10.6 1.3 13.7 7.6 20 6 16 305 38.8 1.3 39.3 33.6 12/25/2005 07:30:00 10.4 1.1 13.7 7.6 10.2 1.2 13 7.6 17 6 17 305 33.5 0.3 33.9 31.7 12/25/2005 07:40:00 10.7 1.2 13.7 8.4 10.6 1.2 13.7 8 16 6 14 305 32.2 0.6 33.6 31.4 12/25/2005 07:50:00 10.8 1.3 14.5 7.6 10.6 1.3 14.1 7.6 19 6 22 305 31.8 0 32 31 12/25/2005 08:00:00 11.2 1.2 13.7 8 11 1.2 14.1 7.6 17 6 8 305 31.6 0.5 33 29.2 12/25/2005 08:10:00 10.7 1.6 14.9 7.2 10.5 1.6 14.1 7.2 19 6 22 305 32.2 0.4 33.3 30.4 12/25/2005 08:20:00 11.4 1.7 14.9 7.6 11.2 1.7 14.9 7.2 21 6 22 305 32.2 0.1 33 31.7 12/25/2005 08:30:00 11.8 1.2 15.3 9.1 11.8 1.2 15.3 8.8 21 5 11 305 32.8 1.5 35.6 31 12/25/2005 08:40:00 12.1 1.2 14.5 9.1 11.9 1.2 14.9 8.8 19 5 22 305 31 2 32.6 26.4 12/25/2005 08:50:00 11.5 1.2 14.1 8.4 11.3 1.3 14.1 8.4 19 5 17 305 32.7 0.5 33.3 28.5 12/25/2005 09:00:00 11.2 1.2 13.7 8.4 11.1 1.2 13.7 8 19 5 22 305 34.6 1 35.6 30.7 12/25/2005 09:10:00 11.9 1.1 14.1 7.6 11.8 1.3 14.5 7.6 17 5 16 305 34.4 1.5 35.9 28.5 12/25/2005 09:20:00 11.2 1.3 14.1 7.6 11.1 1.3 13.7 7.2 17 5 7 305 34.1 1.8 36.2 28.5 12/25/2005 09:30:00 10.5 1 13 8 10.4 1.1 13 7.6 19 5 17 305 35.3 1.1 37.9 33 12/25/2005 09:40:00 11.4 1.1 13.7 8.4 11.3 1.1 13.3 8.4 20 5 25 305 35 1.2 36.9 29.8 12/25/2005 09:50:00 10.5 1 13 8 10.3 1.1 13.3 8 17 6 12 305 35.5 0.1 35.9 35.3 12/25/2005 10:00:00 11.7 1 14.5 9.1 11.6 1.2 14.5 8.4 20 4 17 305 35.6 1.1 36.2 29.8 12/25/2005 10:10:00 11.5 1.1 13.3 8.4 11.4 1.2 13.7 8 19 5 16 305 35.2 1.5 36.2 29.8 12/25/2005 10:20:00 11.3 1 13.7 8.4 11.2 1 13.3 8.8 19 5 25 305 34.5 2 36.6 30.4 12/25/2005 10:30:00 11.3 0.9 13 9.1 11.1 1 13.3 8.8 17 5 14 305 35.7 1.4 36.6 30.1 12/25/2005 10:40:00 11.5 1.2 14.1 8.4 11.2 1.2 14.1 8.8 16 5 15 305 36 0 36.6 35.6 12/25/2005 10:50:00 11.3 1.1 13.7 8 11.2 1.2 14.1 8 17 5 18 305 34.8 1.1 36.2 29.5 12/25/2005 11:00:00 11.7 1 13.3 8.8 11.5 1 13.7 8.4 15 4 15 305 34.3 0.1 34.9 33.6 12/25/2005 11:10:00 12.3 0.8 13.7 9.9 12.1 0.8 14.1 9.5 13 4 12 305 34 0 34.6 33.6 12/25/2005 11:20:00 11.2 1 13.7 8.4 11.1 1.1 13.7 8 14 5 14 305 33.5 0.5 34.3 32 12/25/2005 11:30:00 11.5 1.2 14.1 8.4 11.6 1.2 14.1 7.6 17 5 16 305 32.8 1 33.6 25.5 12/25/2005 11:40:00 12.2 1.2 15.3 8.4 12.2 1.3 14.5 8.4 19 5 20 305 32.6 0 33.3 32.3 12/25/2005 11:50:00 12 1.3 14.5 8.8 11.8 1.3 14.5 8 22 5 21 305 31.9 1.4 33 27.3 12/25/2005 12:00:00 12.1 1.1 14.5 8.8 12 1.1 14.5 8.8 22 5 16 305 31.7 1.2 32.6 27.6 12/25/2005 12:10:00 12.5 1.3 16.1 9.5 12.3 1.3 15.6 8.8 24 5 24 305 28.4 1 30.7 24.9 12/25/2005 12:20:00 13.3 1.3 16.8 9.9 13 1.5 16.8 9.5 25 5 18 305 28.9 2.7 31 19.9 12/25/2005 12:30:00 13.8 1.4 17.6 9.9 13.4 1.3 16.8 9.1 27 5 23 305 30.6 0.8 31.4 26.1 12/25/2005 12:40:00 13.4 1.5 17.2 8.8 12.9 1.5 16.4 9.1 23 6 23 305 29.9 0.2 30.7 29.5 12/25/2005 12:50:00 12.6 1.2 16.1 9.9 12.3 1.3 15.3 9.1 19 5 17 305 30.2 0.2 30.7 29.5 12/25/2005 13:00:00 12 1.2 14.9 8.8 11.9 1.3 14.5 8 18 6 16 305 30.8 0 31.4 30.4 12/25/2005 13:10:00 12.4 1.2 15.3 8.8 12.2 1.3 15.3 9.5 19 5 23 305 30.6 0.4 31.7 29.8 12/25/2005 13:20:00 12.1 1.5 15.6 8.8 11.9 1.6 16.1 8.4 16 5 16 305 31.3 0 31.7 31 12/25/2005 13:30:00 13 1.1 16.1 9.9 12.8 1.1 15.6 9.5 18 5 14 305 30.8 0 31.4 30.4 12/25/2005 13:40:00 12 1.6 15.3 8 12 1.7 15.3 8 18 5 17 305 30.6 0 31 29.8 12/25/2005 13:50:00 12.4 1.3 14.9 8 12.2 1.3 14.9 8.4 14 5 14 305 30.5 0.4 31.4 29.2 12/25/2005 14:00:00 12.3 1.5 15.3 8.8 12 1.5 15.3 8.4 16 6 22 305 30.2 0.9 31.4 23.4 12/25/2005 14:10:00 13.1 1.2 15.6 9.9 12.8 1.2 16.1 9.5 15 5 9 305 31.3 0.5 32.3 29.8 12/25/2005 14:20:00 13 1.3 15.6 9.9 12.9 1.3 16.1 9.9 15 5 19 305 31.6 0.4 32.3 30.4 12/25/2005 14:30:00 12.6 1.4 16.4 9.1 12.5 1.4 16.8 8.4 13 6 13 305 31.4 0 32 31 12/25/2005 14:40:00 13.2 1.3 16.4 9.5 13 1.3 16.4 9.1 14 5 16 305 31.8 0.2 32.3 31 12/25/2005 14:50:00 13.9 1.6 17.9 9.9 13.6 1.5 16.8 9.5 15 5 16 305 32 0 32.6 31.7 12/25/2005 15:00:00 13.5 1.4 16.4 9.9 13.4 1.4 16.4 9.5 15 5 18 305 32.2 0.2 32.6 31.4 12/25/2005 15:10:00 13.3 1.5 16.4 9.5 13 1.6 16.4 8.8 16 5 17 305 32.3 0.2 33 31.7 12/25/2005 15:20:00 14 1.5 16.8 8.8 13.8 1.5 17.2 9.5 15 5 18 305 32.2 0.1 32.6 31.7 12/25/2005 15:30:00 13.3 1.5 16.1 9.1 13.1 1.5 16.4 9.1 16 5 14 305 31.8 0.4 32.6 27.6 12/25/2005 15:40:00 13.5 1.7 16.8 9.5 13.4 1.6 17.2 9.9 17 6 10 305 31.7 0 32.3 30.7 12/25/2005 15:50:00 13 1.5 16.8 8.8 12.9 1.5 16.8 9.1 16 5 13 305 31.7 0 32 31.7 12/25/2005 16:00:00 13.1 1.6 16.8 9.1 13 1.5 17.6 9.1 17 6 14 305 31.6 0 32 31.4 12/25/2005 16:10:00 11.7 1.3 15.3 8.4 11.5 1.4 14.9 8 16 6 14 305 31.1 0.3 31.7 29.8 12/25/2005 16:20:00 12.2 1.4 15.6 8 12.2 1.4 15.3 8 17 5 19 305 31.3 0.4 32 29.8 12/25/2005 16:30:00 12.2 1.4 15.6 9.1 12.1 1.3 15.3 8.8 17 5 18 305 31.4 0.4 32 30.4 12/25/2005 16:40:00 13.1 1.9 18.7 8.8 12.8 1.9 18.7 8 22 6 25 305 31.4 0.3 32.3 30.4 12/25/2005 16:50:00 15.8 1.7 20.2 11.5 15.6 1.7 19.1 11.1 25 6 31 305 31.6 0.3 32.3 30.7 12/25/2005 17:00:00 15.7 1.8 19.9 11.8 15.4 1.8 19.9 11.1 27 6 25 305 32.3 0.4 33.3 31.7 12/25/2005 17:10:00 15.3 1.9 20.2 11.1 15.1 1.8 19.9 11.1 27 6 32 305 33.1 0 33.3 33 12/25/2005 17:20:00 15.4 2.1 20.6 11.1 15.1 2.2 21 11.1 31 6 31 305 33 0.2 33.3 32 12/25/2005 17:30:00 15.4 1.5 20.2 12.2 14.9 1.5 19.1 11.1 30 6 21 305 32.4 0.2 33 31.7 12/25/2005 17:40:00 16.3 1.5 19.9 13 15.9 1.6 19.5 12.2 31 5 31 305 31.9 0 32.6 31 12/25/2005 17:50:00 15.2 1.6 20.6 11.8 14.8 1.7 19.9 11.5 32 6 19 305 31.8 0.1 32 29.5 12/25/2005 18:00:00 15.9 1.5 20.2 11.8 15.7 1.5 19.1 11.5 32 6 31 305 31.8 0.4 32.6 30.4 12/25/2005 18:10:00 15.8 1.9 20.2 10.3 15.6 1.9 20.2 11.1 31 6 23 305 31.4 1.3 33 24.6 12/25/2005 18:20:00 15.6 1.5 19.5 11.1 15.2 1.5 19.9 11.5 33 5 33 305 31.7 2.8 34.3 14.8 12/25/2005 18:30:00 15.9 1.8 19.9 11.8 15.6 1.7 19.9 11.8 30 5 28 305 33.8 0.5 34.9 31.7 12/25/2005 18:40:00 15.7 1.4 18.3 12.6 15.4 1.4 18.7 11.8 32 5 31 305 33.7 0.5 34.6 31 12/25/2005 18:50:00 15.1 1.7 18.7 10.7 14.8 1.7 17.9 10.3 33 6 31 305 32.7 0.5 34.3 30.1 12/25/2005 19:00:00 16.4 1.9 20.6 12.2 16 1.9 20.2 11.5 32 5 29 305 32.2 0.3 33.3 31.7 12/25/2005 19:10:00 16 1.5 20.2 11.8 15.7 1.4 19.5 12.2 35 5 33 305 32.3 0.3 33.3 31.4 12/25/2005 19:20:00 15.7 1.7 19.5 11.5 15.4 1.7 19.9 11.8 36 5 38 305 32.5 0.3 33.3 31.4 12/25/2005 19:30:00 14.3 1.3 17.9 10.3 14 1.3 17.2 10.3 32 6 28 305 32.7 0.2 33.6 32 12/25/2005 19:40:00 15.4 1.7 19.5 11.1 15.1 1.7 19.5 10.7 33 6 25 305 32.2 0.5 33.3 31 12/25/2005 19:50:00 12.7 1.3 16.8 9.9 12.7 1.2 16.4 9.5 34 6 37 305 32 0.4 33 30.7 12/25/2005 20:00:00 15.8 2.1 21.4 11.1 15.5 1.9 21.4 11.1 33 6 36 305 31.8 0.3 32.6 31 12/25/2005 20:10:00 16 1.7 20.2 11.1 15.7 1.7 19.5 10.7 36 6 29 305 31.5 0.3 32.3 30.4 12/25/2005 20:20:00 14.5 1.5 19.1 10.7 14.3 1.4 18.3 10.3 37 6 36 305 31.3 0.5 32.6 28.8 12/25/2005 20:30:00 15.4 1.8 19.1 9.9 15 1.8 18.7 9.9 38 7 45 305 31 1.5 33.3 25.5 12/25/2005 20:40:00 14.8 1.8 19.1 10.7 14.6 1.8 18.7 9.9 35 6 29 305 31.5 0.6 33 29.8 12/25/2005 20:50:00 13.5 1.7 17.9 9.5 13.3 1.7 17.6 9.5 37 7 39 305 32.4 0.5 33.3 30.1 12/25/2005 21:00:00 13.5 1.6 16.8 9.5 13.2 1.6 16.8 9.1 37 7 29 305 31.9 0.3 32.6 30.4 12/25/2005 21:10:00 12.9 1.7 16.4 9.1 12.6 1.7 16.8 9.1 39 6 38 305 31.5 0.6 32.6 29.8 12/25/2005 21:20:00 14.8 2.3 19.9 9.9 14.6 2.3 19.1 9.5 39 7 35 305 31.8 0.2 32.3 31 12/25/2005 21:30:00 14 1.9 18.7 9.9 13.7 1.8 17.9 9.5 38 7 39 305 31.3 0.5 32 29.8 12/25/2005 21:40:00 13.5 2 17.9 9.1 13.4 1.9 17.6 9.5 36 6 32 305 31.7 0.4 32.3 29.8 12/25/2005 21:50:00 13.8 2.1 18.3 8.8 13.5 2.1 18.3 8.8 33 6 28 305 31.8 0.2 32.3 31 12/25/2005 22:00:00 13.1 1.8 17.2 9.1 13 1.7 17.2 9.1 34 6 41 305 31.9 0 32.3 31.7 12/25/2005 22:10:00 14.6 1.7 18.3 9.1 14.2 1.7 17.9 9.1 33 6 30 305 32 0.4 32.6 28.8 12/25/2005 22:20:00 14.4 2.3 18.7 8.4 14 2.3 19.1 8.4 29 7 25 305 31.9 0.1 32.3 31.4 12/25/2005 22:30:00 16.6 1.6 20.2 12.6 16.1 1.6 19.9 11.8 32 6 33 305 31.1 0.5 32 29.2 12/25/2005 22:40:00 14.8 1.7 19.1 10.3 14.5 1.7 18.7 9.5 36 7 38 305 31 0.2 31.4 29.8 12/25/2005 22:50:00 13.5 1.6 17.9 9.9 13.3 1.6 17.9 8.8 37 6 40 305 31 1.2 33 24 12/25/2005 23:00:00 15.1 1.7 18.7 10.3 14.8 1.7 18.3 9.9 35 5 38 305 31.8 0.1 33 31 12/25/2005 23:10:00 15.7 2.1 19.5 11.5 15.4 2.1 19.5 10.3 36 6 30 305 31.5 0.1 32.3 31 12/25/2005 23:20:00 16.3 1.9 20.2 10.7 16 1.8 20.2 10.7 34 6 37 305 31.2 0.3 32 29.8 12/25/2005 23:30:00 15.2 1.8 18.7 10.3 14.8 1.9 18.7 9.5 34 7 36 305 31.5 0 32 30.7 12/25/2005 23:40:00 15 1.7 18.7 11.1 14.6 1.7 18.3 10.7 36 6 23 305 31.3 0 31.7 30.7 12/25/2005 23:50:00 15.5 1.8 19.5 10.3 15.3 1.7 19.5 8.8 33 5 29 305 31.3 0.4 32.3 29.8 12/26/2005 00:00:00 15.6 2.1 19.9 9.9 15.2 2.1 19.9 9.9 33 5 26 305 31 0.3 31.7 29.8 12/26/2005 00:10:00 14.1 1.8 18.3 10.3 13.8 1.8 17.9 9.9 31 6 29 305 30.6 0.2 31.7 29.8 12/26/2005 00:20:00 15.6 1.5 19.5 11.8 15.4 1.4 18.7 11.5 30 6 26 305 30.8 0.1 31.4 30.1 12/26/2005 00:30:00 16.2 1.9 19.9 11.8 15.9 1.9 19.9 11.5 33 6 30 305 31.2 0.7 32.6 28.5 12/26/2005 00:40:00 15.7 1.7 19.9 11.5 15.2 1.7 19.1 10.7 33 6 19 305 31.3 0.6 32.3 29.8 12/26/2005 00:50:00 16.8 1.8 20.6 12.2 16.4 1.7 20.6 11.8 35 6 31 305 32.6 0.6 33.3 29.5 12/26/2005 01:00:00 15.4 1.9 19.9 10.3 15 1.9 20.2 9.9 34 6 27 305 32.8 0.1 33.3 32 12/26/2005 01:10:00 13.8 2.6 19.9 8.4 13.6 2.5 19.5 8.4 29 9 35 305 32.4 0.2 33.3 31.4 12/26/2005 01:20:00 11.5 1.2 14.9 8.4 11.3 1.2 14.1 8 18 5 16 305 32.5 0.2 33.3 31.7 12/26/2005 01:30:00 11.9 1.4 15.3 8 11.8 1.4 15.3 8 21 5 19 305 33.5 0.3 33.9 32.3 12/26/2005 01:40:00 12.4 1.1 14.9 9.1 12.3 1.1 14.5 9.5 21 5 20 305 33.5 0.3 33.9 32 12/26/2005 01:50:00 11.7 1 14.1 9.1 11.5 1 14.1 8.8 16 5 17 305 31.6 2.8 34.3 20.1 12/26/2005 02:00:00 13.7 1.4 16.8 9.9 13.5 1.4 16.8 9.1 19 5 17 305 31.8 0.4 33 31 12/26/2005 02:10:00 14.6 1.9 18.7 9.1 14.4 1.9 18.3 8.8 22 5 18 305 31.7 0.5 32.3 29.5 12/26/2005 02:20:00 14.4 1.8 18.3 9.9 14.2 1.8 18.3 9.9 23 5 22 305 30.1 0.5 31.4 29.2 12/26/2005 02:30:00 14.8 1.8 18.3 9.5 14.6 1.8 18.7 9.9 21 6 19 305 30.5 0.6 31.7 28.8 12/26/2005 02:40:00 14.6 1.7 17.9 9.9 14.3 1.7 18.3 9.5 20 6 17 305 30.4 1 31.7 27.6 12/26/2005 02:50:00 14.5 1.6 18.3 10.7 14.2 1.6 18.3 10.7 15 5 14 305 29.5 0.7 31 26.4 12/26/2005 03:00:00 14.2 1.5 18.3 10.7 14 1.5 17.6 10.3 20 6 18 305 30.8 0.3 31.7 30.1 12/26/2005 03:10:00 12.7 1.6 16.4 9.5 12.6 1.5 17.2 9.5 21 7 18 305 31.8 0.1 32 30.7 12/26/2005 03:20:00 13.3 1.3 16.1 10.7 13.2 1.5 16.1 9.9 21 5 18 305 32.1 0 32.3 31.4 12/26/2005 03:30:00 14.7 1.4 20.2 11.5 14.4 1.5 19.5 11.1 22 5 19 305 32.2 0.1 32.6 31.7 12/26/2005 03:40:00 14.5 1.6 19.5 10.7 14.3 1.5 19.1 10.3 26 6 17 305 31.9 0 32 31.4 12/26/2005 03:50:00 15.4 1.5 19.1 12.2 15.1 1.5 18.7 11.8 26 5 24 305 33 0.9 34.3 31.7 12/26/2005 04:00:00 15.3 1.5 18.3 10.7 15 1.4 17.9 11.1 28 6 35 305 34.1 0 34.3 33.6 12/26/2005 04:10:00 14.2 1.4 18.3 11.1 14.1 1.4 17.6 10.7 24 6 24 305 33.5 0.4 34.3 33 12/26/2005 04:20:00 14.5 1.3 17.9 11.5 14.3 1.3 17.6 11.1 19 5 22 305 33.6 0 34.3 33.3 12/26/2005 04:30:00 14.1 1.6 17.9 10.7 13.8 1.7 17.6 9.9 20 5 19 305 34.8 0.2 35.3 33.9 12/26/2005 04:40:00 13.4 1.5 16.8 9.9 13.2 1.5 17.2 9.5 19 5 17 305 34.8 0 34.9 34.3 12/26/2005 04:50:00 13 1.3 15.6 9.1 12.9 1.3 15.6 9.5 19 5 15 305 34.7 0 34.9 34.3 12/26/2005 05:00:00 12.8 1.1 15.3 9.9 12.6 1.2 15.6 8.8 20 5 14 305 34.8 0 34.9 34.6 12/26/2005 05:10:00 12.6 1.4 16.1 9.1 12.3 1.5 16.1 8.8 18 5 20 305 35.2 0.1 35.3 34.9 12/26/2005 05:20:00 11.7 1.2 14.9 8 11.6 1.2 14.1 8.8 17 5 8 305 35.3 0 35.3 35.3 12/26/2005 05:30:00 11.7 1.1 14.1 8.4 11.6 1.1 14.1 8.4 16 5 16 305 35.4 0 35.9 35.3 12/26/2005 05:40:00 10.7 1.5 13.7 7.2 10.5 1.5 14.1 6.8 22 6 21 305 35.6 0 35.9 35.3 12/26/2005 05:50:00 12.7 1.5 16.1 8.4 12.4 1.6 16.4 7.6 26 5 23 305 35.6 0 35.9 35.3 12/26/2005 06:00:00 13.2 1.2 16.1 9.9 13 1.2 15.6 9.5 27 5 33 305 35.6 0 35.9 35.3 12/26/2005 06:10:00 12.6 1.1 15.3 9.5 12.5 1.2 15.6 9.1 24 5 18 305 35.7 0 35.9 35.3 12/26/2005 06:20:00 12.7 1.7 16.4 8.8 12.5 1.7 16.4 8.8 25 6 27 305 35.7 0 35.9 35.6 12/26/2005 06:30:00 13.1 1.1 16.4 9.9 13 1.1 16.4 10.3 24 6 24 305 35.8 0 35.9 35.6 12/26/2005 06:40:00 14 1.1 17.2 11.1 13.9 1.1 17.2 11.1 25 5 20 305 35.9 0 36.2 35.9 12/26/2005 06:50:00 14.1 1.2 17.2 10.7 13.9 1.2 17.6 10.7 23 5 21 305 35.8 0 36.2 35.9 12/26/2005 07:00:00 15 1.5 18.3 11.5 14.8 1.5 18.7 11.1 26 5 30 305 35.8 0 36.2 35.9 12/26/2005 07:10:00 14.7 1.5 17.9 10.3 14.5 1.5 17.6 10.3 25 5 21 305 36 0 36.2 35.9 12/26/2005 07:20:00 14.6 1.3 17.6 11.1 14.4 1.4 17.2 11.5 24 5 30 305 36 0 36.2 35.9 12/26/2005 07:30:00 13.7 1.3 16.8 9.9 13.6 1.3 16.8 9.5 22 5 29 305 36 0 36.2 35.9 12/26/2005 07:40:00 13.1 1.2 16.1 9.9 12.8 1.2 15.6 9.9 22 6 23 305 36.8 0.9 37.9 35.9 12/26/2005 07:50:00 13.7 1.5 16.8 9.5 13.6 1.4 16.4 9.9 24 5 25 305 37.4 0.4 37.9 36.6 12/26/2005 08:00:00 14.3 1.3 17.9 11.5 14 1.3 17.6 10.3 24 5 28 305 37.4 0.4 37.9 35.9 12/26/2005 08:10:00 15 1.5 19.1 10.7 14.6 1.5 18.3 10.7 28 6 22 305 37.7 0.6 38.6 35.3 12/26/2005 08:20:00 15.8 2.2 22.6 10.7 15.5 2.2 22.1 10.3 30 7 42 305 37.7 0.4 38.3 35.3 12/26/2005 08:30:00 17.5 2 21.8 11.8 17.4 1.9 22.1 12.2 34 5 40 305 37.7 0.6 38.6 33.6 12/26/2005 08:40:00 18.4 1.5 22.1 14.5 17.9 1.5 21.4 14.1 32 5 32 305 37.5 0.5 38.3 35.9 12/26/2005 08:50:00 16.5 1.7 20.6 12.2 16.2 1.6 19.9 12.2 32 5 29 305 37.8 0.5 38.6 36.6 12/26/2005 09:00:00 17.1 1.7 21.4 12.6 16.8 1.7 21.4 10.7 31 6 31 305 38.5 0.5 38.9 37.2 12/26/2005 09:10:00 17 1.6 21.4 13 16.6 1.7 20.6 12.2 30 5 19 305 38.5 0.5 39.3 36.9 12/26/2005 09:20:00 17.7 2.3 24 13 17.2 2.2 22.9 12.6 30 6 26 305 38.8 0.4 39.3 37.6 12/26/2005 09:30:00 18 2.1 23.7 13.3 17.5 2.1 22.9 13.3 32 6 30 305 37.9 0.5 39.3 36.6 12/26/2005 09:40:00 18.4 1.9 23.7 13.7 18 1.8 22.6 13 30 6 33 305 38.6 0.3 38.9 37.6 12/26/2005 09:50:00 18.9 1.5 23.3 15.3 18.5 1.5 23.3 14.5 30 5 31 305 39.1 0.4 40.3 35.9 12/26/2005 10:00:00 18.4 2.3 23.3 13 18 2.3 23.3 11.8 29 6 18 305 40.1 0 40.3 40 12/26/2005 10:10:00 20.3 1.7 24.4 14.9 19.8 1.7 23.7 14.9 29 5 32 305 41.9 0.8 42.7 39.6 12/26/2005 10:20:00 20.6 1.9 24.8 15.6 20 1.8 24 14.9 28 5 29 305 42.1 0.4 42.7 40.3 12/26/2005 10:30:00 20.4 2.1 25.2 14.9 19.8 2.1 24 13.7 27 5 23 305 40.3 0.6 41.7 38.6 12/26/2005 10:40:00 18.8 2.3 23.3 13 18.3 2.1 22.9 13 28 6 28 305 38.8 2.7 41.3 17.9 12/26/2005 10:50:00 20.2 1.7 23.7 16.1 19.5 1.7 23.3 14.9 30 5 31 305 36.7 2.8 39.3 22.2 12/26/2005 11:00:00 18.7 2.1 23.7 13.3 18.3 2.1 23.3 13 30 5 29 305 38.1 1 39.3 31.7 12/26/2005 11:10:00 16.7 2.2 21.8 11.8 16.2 2.1 21.4 11.5 31 6 26 305 38 1.2 39.6 34.3 12/26/2005 11:20:00 16.7 1.5 21 12.6 16.4 1.5 21 13 32 6 30 305 40.3 2.1 41.7 34.6 12/26/2005 11:30:00 17 2 21.4 12.6 16.6 2.1 21.4 12.2 33 6 31 305 39.9 0.3 41 38.6 12/26/2005 11:40:00 16.4 1.9 21 11.5 16 1.9 21 11.1 33 6 31 305 39.5 0.4 40.6 38.3 12/26/2005 11:50:00 16.3 1.8 20.2 11.5 15.9 1.7 19.5 11.8 34 6 37 305 38.6 0.1 39.3 38.3 12/26/2005 12:00:00 16 1.7 19.9 11.5 15.7 1.6 19.5 11.8 34 5 35 305 38.9 0 39.3 38.6 12/26/2005 12:10:00 16.4 1.8 23.3 12.2 16 1.7 22.1 11.8 32 5 35 305 39.1 0 39.3 38.6 12/26/2005 12:20:00 15.9 1.8 21 11.8 15.6 1.7 21.4 11.1 33 6 36 305 39.4 0.2 39.6 38.3 12/26/2005 12:30:00 15.1 1.7 19.5 10.7 14.7 1.7 19.9 10.7 31 6 33 305 39.4 0 39.6 38.9 12/26/2005 12:40:00 16 1.6 19.9 11.5 15.7 1.6 19.9 11.5 30 6 27 305 39.2 0 39.6 38.9 12/26/2005 12:50:00 15.3 1.6 20.6 11.5 14.9 1.7 20.6 11.1 29 6 32 305 39.2 0 39.6 38.9 12/26/2005 13:00:00 15.7 1.7 19.5 11.1 15.4 1.7 20.2 10.3 28 5 23 305 38.9 0.2 39.6 38.3 12/26/2005 13:10:00 15.9 1.7 19.9 11.8 15.5 1.6 19.1 11.1 28 6 28 305 39.3 0.2 40 38.3 12/26/2005 13:20:00 16.6 2.3 22.6 11.8 16.2 2.3 21.8 11.5 28 5 29 305 39.3 0 39.6 38.3 12/26/2005 13:30:00 17.4 2 22.1 12.6 17 1.9 21.8 12.6 31 6 32 305 38.7 0.6 39.6 32.6 12/26/2005 13:40:00 17.3 1.9 21.8 13 17 2 21.8 11.8 30 6 35 305 38.7 0.1 39.3 38.3 12/26/2005 13:50:00 16.9 2.1 21.8 12.2 16.6 2 21.4 11.8 29 6 24 305 38.6 0.5 39.3 34.6 12/26/2005 14:00:00 17.1 1.7 21.8 13 16.7 1.7 21 13 29 6 27 305 39.1 0 40 38.3 12/26/2005 14:10:00 17.7 1.9 22.1 13.7 17.3 1.9 22.1 11.8 29 6 29 305 39.4 0 39.6 38.9 12/26/2005 14:20:00 17.8 2.1 22.1 13.3 17.5 2 23.3 13.3 28 6 33 305 39.5 0 39.6 38.9 12/26/2005 14:30:00 18 1.9 22.6 13 17.6 1.9 22.1 13 31 5 27 305 39.5 0 40 39.3 12/26/2005 14:40:00 17.9 2.1 24 13 17.5 2 22.6 12.6 31 5 26 305 39.6 0 40 39.3 12/26/2005 14:50:00 19.4 1.5 22.6 15.3 18.8 1.7 22.6 13.7 32 5 34 305 39.4 0 39.6 39.3 12/26/2005 15:00:00 18.2 1.9 22.1 14.1 17.7 1.8 22.9 12.2 31 5 30 305 39.4 0 39.6 39.3 12/26/2005 15:10:00 18.6 1.7 22.1 14.1 18.1 1.7 21.8 13.3 31 5 32 305 39.6 0.7 40.3 34.3 12/26/2005 15:20:00 17.8 1.9 22.9 13.7 17.5 1.9 22.1 13.3 32 5 28 305 39.1 0 39.6 38.9 12/26/2005 15:30:00 18.5 2.5 23.7 13 18.1 2.4 23.7 13 31 5 33 305 38.8 0.2 39.3 38.3 12/26/2005 15:40:00 19.4 1.8 23.3 14.1 18.9 1.7 22.9 13.3 31 5 33 305 37.9 0.8 39.3 31.7 12/26/2005 15:50:00 18.7 1.5 22.1 14.5 18.2 1.5 21.8 14.5 31 5 36 305 38.3 0.3 38.9 35.9 12/26/2005 16:00:00 18 1.9 21.8 13.3 17.5 1.8 21.8 13 31 5 32 305 38 0.6 38.9 33.3 12/26/2005 16:10:00 18.3 2.7 23.7 11.8 17.8 2.8 23.7 11.5 31 6 37 305 38.2 0.1 38.6 37.6 12/26/2005 16:20:00 17.2 2.8 23.7 11.8 16.7 2.7 23.3 11.5 32 5 30 305 38.7 0 38.9 38.6 12/26/2005 16:30:00 17.1 1.7 21 12.2 16.6 1.7 21 12.2 29 5 27 305 38.4 0 38.9 37.9 12/26/2005 16:40:00 18 2.1 22.9 12.2 17.6 2 22.6 12.6 29 6 35 305 38.9 0.5 39.6 34.3 12/26/2005 16:50:00 18.7 2.3 23.7 13.3 18.1 2.2 23.7 13 28 6 32 305 38.8 0.6 39.6 36.6 12/26/2005 17:00:00 18 2.1 22.9 13.7 17.5 2 22.6 13 28 6 33 305 38.3 0.2 39.3 37.6 12/26/2005 17:10:00 18.4 1.7 23.7 14.1 17.8 1.7 21.8 13.3 30 6 31 305 37.2 1.1 38.6 34.3 12/26/2005 17:20:00 19.3 2 24.4 14.1 18.7 2 24.8 13.7 28 6 31 305 36.4 0.6 37.6 34.3 12/26/2005 17:30:00 19.7 1.6 22.9 15.3 19.1 1.6 23.3 14.9 28 5 26 305 36.3 0.3 36.9 34.9 12/26/2005 17:40:00 18.4 1.8 22.9 13 18 1.7 22.6 13 29 5 25 305 36.6 1.4 37.9 26.4 12/26/2005 17:50:00 17.4 1.7 22.1 13.3 17 1.7 21 13.3 33 6 28 305 38.3 0.6 39.3 35.9 12/26/2005 18:00:00 17.1 1.9 21.4 12.6 16.7 1.7 21.4 12.6 31 6 34 305 38.1 0.4 38.6 35.3 12/26/2005 18:10:00 19.9 1.9 24.4 14.9 19.4 2 23.7 14.9 29 5 27 305 38.3 0 38.9 37.9 12/26/2005 18:20:00 20 1.9 24.8 14.5 19.4 1.9 23.7 13.7 31 5 36 305 38.2 0 38.9 37.9 12/26/2005 18:30:00 19.7 2.1 24.4 14.1 19.3 2.1 23.7 13.7 33 5 32 305 37.9 0 38.6 37.6 12/26/2005 18:40:00 18.9 2.1 24.4 14.1 18.4 2.2 23.7 13.7 34 6 35 305 37.9 0.1 38.6 37.2 12/26/2005 18:50:00 19.4 2.2 24.4 14.1 18.9 2.1 23.7 13.7 33 5 35 305 37.8 0.2 38.6 37.2 12/26/2005 19:00:00 18.3 2.5 24.8 13 17.9 2.4 24 13.3 29 5 32 305 36.8 0.3 37.6 36.2 12/26/2005 19:10:00 17 2 21.4 12.2 16.8 1.9 21.8 12.6 31 6 22 305 36.9 0.1 37.6 35.3 12/26/2005 19:20:00 17.4 1.7 22.1 13.7 17 1.9 21.8 12.2 32 6 37 305 36.6 0.8 37.6 34.6 12/26/2005 19:30:00 19.3 1.7 22.6 14.9 18.9 1.6 22.6 13.7 30 5 31 305 33.9 1.9 35.3 29.8 12/26/2005 19:40:00 18.2 1.8 22.1 13 17.7 1.9 22.6 12.2 32 7 33 305 29.9 0.3 30.7 29.2 12/26/2005 19:50:00 15.2 2.8 22.9 9.9 14.9 2.7 22.9 10.3 22 7 22 305 29.2 1 30.4 26.4 12/26/2005 20:00:00 15.4 2.6 21.4 10.7 15.2 2.6 21.4 10.7 28 8 33 305 29.5 0.7 30.7 28.8 12/26/2005 20:10:00 17 3.2 23.3 11.1 16.7 2.9 23.3 10.3 28 6 27 305 32.3 2.4 35.3 28.2 12/26/2005 20:20:00 18.2 2.5 23.3 12.6 17.9 2.4 22.9 12.6 32 6 30 305 33.8 0.3 35.3 33.3 12/26/2005 20:30:00 18.5 2.1 24 14.1 18.1 2 23.7 14.1 35 5 35 305 33.8 0 34.3 33.3 12/26/2005 20:40:00 18.6 2.4 23.7 12.6 18.1 2.3 23.3 13 34 5 27 305 31 2.3 33.9 25.5 12/26/2005 20:50:00 17.4 2.2 22.6 12.6 17.1 2.2 22.6 12.2 33 6 35 305 28.1 1 30.1 24.9 12/26/2005 21:00:00 18.3 2.2 24.4 13.3 17.8 2.1 23.3 13 33 6 48 305 28 0.5 29.2 25.8 12/26/2005 21:10:00 19.6 2.3 26.3 14.5 19.1 2.3 26 14.5 31 5 41 305 26.5 3.1 28.8 11.3 12/26/2005 21:20:00 18.1 2.3 23.7 13 17.6 2.2 24 12.6 30 6 31 305 26.5 0.8 27.6 23.7 12/26/2005 21:30:00 18.3 2.6 24 13 17.9 2.4 23.7 13 32 6 32 305 27.2 0.2 27.9 26.4 12/26/2005 21:40:00 18.5 2.1 24.4 13.7 18 2 23.7 13.3 30 6 26 305 26.4 0.5 27.3 23.4 12/26/2005 21:50:00 17.8 2 22.9 13 17.3 1.9 22.1 13 30 6 18 305 26.4 8.7 34.3 3.2 12/26/2005 22:00:00 16.3 2.2 21 10.7 15.8 2.2 21 11.1 32 7 26 305 28.2 8 34.9 9.7 12/26/2005 22:10:00 16.5 2.2 21.4 11.1 16.1 2.2 20.6 11.1 33 6 29 305 35.8 0.3 36.6 34.9 12/26/2005 22:20:00 17.2 2.5 22.9 12.2 16.7 2.5 23.3 10.3 33 6 31 305 25.4 9.5 36.6 13.2 12/26/2005 22:30:00 17.3 2.1 22.1 12.2 16.9 2.1 22.1 12.2 32 6 33 305 26.4 5.4 34.9 20.1 12/26/2005 22:40:00 17.9 1.9 22.1 13.7 17.5 1.8 22.1 13 34 5 31 305 26.1 4 34.3 20.7 12/26/2005 22:50:00 17.6 2.1 22.9 13 17.4 2.1 23.3 13.7 33 6 33 305 27.1 1.6 29.5 23.7 12/26/2005 23:00:00 17.9 2.3 23.3 13.3 17.4 2.3 22.6 12.6 31 6 29 305 27.8 0.4 28.5 26.7 12/26/2005 23:10:00 17.8 2.1 22.6 11.5 17.2 2.1 22.1 11.1 31 5 29 305 27.9 0.2 28.8 27 12/26/2005 23:20:00 17.6 2 22.6 12.6 17.2 1.9 22.6 11.8 32 6 31 305 28.1 0.2 28.8 27.3 12/26/2005 23:30:00 18.3 1.8 22.6 14.1 17.8 1.8 22.6 13.7 29 6 24 305 28.3 0.1 28.8 27.3 12/26/2005 23:40:00 17.9 2.1 23.3 12.2 17.6 2.1 22.6 12.2 34 5 32 305 28.3 0.2 29.2 27.6 12/26/2005 23:50:00 19 1.8 23.3 14.5 18.4 1.8 22.6 14.1 33 6 31 305 28.1 0.2 28.8 27.3 12/27/2005 00:00:00 19.2 1.9 23.3 13.7 18.8 1.8 23.3 13.7 33 5 36 305 28.1 0.1 28.8 27.3 12/27/2005 00:10:00 18.2 2.5 22.9 13.3 17.6 2.5 24 13 31 6 31 305 29.4 1.1 31.4 27.9 12/27/2005 00:20:00 18.6 1.9 23.7 14.1 18.1 2 23.3 13.7 31 6 28 305 31.1 0.2 31.7 30.4 12/27/2005 00:30:00 19.9 2 25.6 15.3 19.4 1.9 25.2 15.3 33 6 27 305 31.1 0.1 31.7 30.7 12/27/2005 00:40:00 17.5 2.1 23.7 13 17.1 1.9 22.1 13 32 5 32 305 31 0.2 31.7 29.8 12/27/2005 00:50:00 19.2 2.4 24.4 14.1 18.7 2.4 23.3 13 31 5 30 305 30.7 0.2 31.4 29.2 12/27/2005 01:00:00 20.9 2.1 26 15.3 20.4 2.1 25.2 14.9 31 5 26 305 31 0.2 31.7 27.3 12/27/2005 01:10:00 20.3 2.3 24.8 14.1 19.9 2.2 24.4 14.9 31 5 32 305 31 0.1 31.7 30.1 12/27/2005 01:20:00 19.4 2.2 24.4 14.5 18.9 2.2 24 14.1 32 6 30 305 30.9 0.4 31.7 29.5 12/27/2005 01:30:00 18.8 2.2 23.3 12.6 18.5 2 22.9 13.3 32 5 35 305 30.7 0.1 31.4 30.1 12/27/2005 01:40:00 17.7 2.1 22.6 11.8 17.2 2 21.8 11.8 29 6 15 305 30.6 0 31.4 30.4 12/27/2005 01:50:00 17.9 2 22.1 12.2 17.5 1.9 22.6 13.3 31 6 31 305 30.3 0.5 31.4 27.9 12/27/2005 02:00:00 18.3 2.6 24.4 12.6 17.9 2.5 23.7 12.6 30 6 33 305 30.7 0.5 32 29.8 12/27/2005 02:10:00 19.4 1.9 24 14.1 18.9 1.9 23.3 14.5 31 6 37 305 31 0.3 31.7 29.8 12/27/2005 02:20:00 19.8 1.7 24 15.3 19.2 1.7 23.3 15.3 29 5 29 305 31 0.3 32 29.2 12/27/2005 02:30:00 18.9 1.8 23.7 14.5 18.5 1.8 23.7 14.9 32 5 34 305 31 0.1 32 30.4 12/27/2005 02:40:00 19.1 2 23.7 14.1 18.6 2 24.4 13.7 30 6 31 305 31.2 0.3 32 30.4 12/27/2005 02:50:00 18.7 2.1 23.7 14.1 18.3 2.1 22.6 14.1 32 5 33 305 31 0.3 31.7 29.5 12/27/2005 03:00:00 19.8 1.9 23.7 14.9 19.2 2 23.3 13.7 30 6 39 305 30.6 0.6 31.7 28.5 12/27/2005 03:10:00 19.7 1.8 24 14.5 19.1 1.8 23.7 14.5 32 6 31 305 30.7 0.4 32 28.8 12/27/2005 03:20:00 20.7 1.7 24 15.3 20.2 1.7 24 14.9 34 5 33 305 32.3 2.6 35.3 20.1 12/27/2005 03:30:00 20 2.1 24.8 14.5 19.5 2.2 24.4 14.1 33 5 28 305 34.1 0.4 34.9 31.4 12/27/2005 03:40:00 20.3 1.7 24 15.6 19.9 1.7 23.7 15.3 34 6 35 305 34.4 0.3 35.3 33.3 12/27/2005 03:50:00 19.5 2 24.4 14.5 19.2 1.9 23.7 13.7 35 5 41 305 34.3 0.2 35.9 33.6 12/27/2005 04:00:00 18.8 1.8 23.3 13.7 18.5 1.8 22.9 13.7 35 6 35 305 35.6 0.2 36.2 34.9 12/27/2005 04:10:00 19.8 2.3 24.4 14.5 19.3 2.3 24 14.1 33 6 32 305 34.8 0.6 35.9 33.6 12/27/2005 04:20:00 20.7 2.1 26 15.6 20.2 2 25.6 15.6 31 6 25 305 34.1 0 34.9 33.6 12/27/2005 04:30:00 18.2 2 24 13.3 17.7 2 22.9 13 31 5 30 305 33.9 0.9 36.2 32.6 12/27/2005 04:40:00 18.2 1.7 22.6 13.7 17.8 1.7 22.9 13.7 31 5 29 305 35.9 0.1 36.9 35.3 12/27/2005 04:50:00 18.7 2.1 23.3 13 18.2 2.2 22.9 12.2 30 5 28 305 35.8 0 36.6 35.3 12/27/2005 05:00:00 17.5 2 22.1 13 17 1.7 21.4 12.6 29 6 32 305 35.7 0.2 36.6 34.9 12/27/2005 05:10:00 17.1 2.1 22.1 12.2 16.7 2.1 21.8 11.5 31 6 32 305 35.3 0.4 35.9 30.4 12/27/2005 05:20:00 16.9 1.9 21.8 11.8 16.5 1.8 22.1 11.8 31 6 35 305 35.7 0.2 36.6 34.9 12/27/2005 05:30:00 17.1 1.7 21 12.2 16.8 1.7 21.4 11.8 34 6 29 305 35.7 0.3 36.9 35.3 12/27/2005 05:40:00 17.5 2.1 23.3 13.3 17.1 2.1 22.9 13.3 33 6 40 305 33.5 0.8 35.9 32.6 12/27/2005 05:50:00 19 1.9 24 14.1 18.6 2.2 23.7 13.7 34 6 35 305 32.9 0.1 33.6 32.3 12/27/2005 06:00:00 19.8 1.8 22.9 14.1 19.3 1.8 23.7 14.5 36 5 35 305 32.4 0.4 33.3 31 12/27/2005 06:10:00 19.3 2 24 13.3 18.9 2 23.3 13.3 35 5 38 305 33 0 33.6 32.6 12/27/2005 06:20:00 18.4 1.9 22.9 12.2 18 1.9 22.1 13 37 6 40 305 32.8 0 33.3 32.3 12/27/2005 06:30:00 18.7 2 22.9 13 18.3 2.1 22.9 13 36 5 37 305 32.4 0.2 33.3 31.4 12/27/2005 06:40:00 19.6 1.8 23.7 14.5 19.3 1.7 23.7 15.6 35 5 49 305 32.6 0.2 33.3 31.7 12/27/2005 06:50:00 16 1.8 20.6 11.8 15.7 1.8 20.2 10.7 34 6 32 305 33 0.3 34.6 32.3 12/27/2005 07:00:00 16.2 1.9 21.4 11.5 15.7 1.8 20.2 11.5 32 6 33 305 34 0.2 34.9 33 12/27/2005 07:10:00 16.9 1.5 22.6 11.8 16.6 1.5 21.4 12.6 36 6 30 305 34.2 0.2 34.9 33.3 12/27/2005 07:20:00 15.9 2.1 22.1 11.5 15.7 2.1 21.8 11.5 34 6 32 305 34.2 0.4 35.3 33.3 12/27/2005 07:30:00 16.3 1.6 21 11.5 15.8 1.5 20.2 12.2 32 6 21 305 34.1 0.2 35.3 33 12/27/2005 07:40:00 15.2 2.4 21.4 10.7 14.8 2.3 21 11.1 31 6 37 305 34 0.1 34.9 33.3 12/27/2005 07:50:00 15.7 2.1 21.4 11.1 15.4 2.1 21.4 11.5 35 6 30 305 33.7 0.2 34.6 33 12/27/2005 08:00:00 15.4 1.9 19.9 11.5 15.1 1.9 20.2 11.1 35 6 35 305 33.2 0.2 33.9 32.3 12/27/2005 08:10:00 16.7 2.1 21.8 11.8 16.2 2 20.6 11.5 33 6 36 305 33.2 0.3 34.3 32.3 12/27/2005 08:20:00 17.1 2 21.8 12.2 16.7 1.9 21.8 12.2 35 6 34 305 32.5 0.5 33.6 29.5 12/27/2005 08:30:00 15.5 2 21.4 11.1 15.1 2 20.2 10.3 32 7 35 305 29.6 1.8 33.3 27.9 12/27/2005 08:40:00 18.1 2.2 22.1 12.6 17.6 2.1 21.8 13 31 5 36 305 31.2 1.2 32.6 28.5 12/27/2005 08:50:00 16.9 1.8 21.8 12.6 16.4 1.8 21.8 12.2 32 6 32 305 25.7 1.6 31.7 22.2 12/27/2005 09:00:00 17.2 1.7 21 11.8 16.6 1.6 20.2 12.6 32 5 36 305 25.3 0.4 26.4 24 12/27/2005 09:10:00 15.2 1.9 19.5 11.5 15 1.8 19.1 11.5 30 6 30 305 26.4 1 28.8 24.6 12/27/2005 09:20:00 14.8 1.5 18.7 11.5 14.6 1.2 19.1 11.8 31 6 44 305 30.5 1.2 32 26.4 12/27/2005 09:30:00 15.5 1.7 19.9 10.7 15.2 1.7 19.9 10.7 30 6 33 305 30.5 3.1 32.6 22.5 12/27/2005 09:40:00 16.3 2.1 20.6 11.1 15.8 2.2 21.8 10.7 30 6 23 305 27 3.4 31.7 21.9 12/27/2005 09:50:00 17.2 1.8 21.8 12.6 16.8 1.7 21.8 13.3 32 6 37 305 29.7 1.6 33 20.4 12/27/2005 10:00:00 16.9 2.5 21.8 11.5 16.6 2.4 21.4 11.1 35 6 37 305 32.6 0.6 33.3 31 12/27/2005 10:10:00 16 2 20.6 11.5 15.6 2.1 21 9.9 32 6 33 305 33.7 0.1 34.3 33.3 12/27/2005 10:20:00 14.7 1.9 19.5 10.7 14.5 2 19.9 10.7 35 5 34 305 34 0.3 34.9 33.3 12/27/2005 10:30:00 15.9 1.4 19.1 11.8 15.5 1.4 18.7 11.5 35 6 33 305 35.5 0.5 36.6 34.3 12/27/2005 10:40:00 15.4 1.6 19.1 11.1 15 1.6 19.1 11.1 33 7 30 305 35.8 0.2 36.6 34.6 12/27/2005 10:50:00 15.2 1.7 20.2 11.5 14.8 1.7 19.5 11.5 35 6 32 305 35.7 0.1 36.6 35.3 12/27/2005 11:00:00 15.5 1.6 19.1 12.2 15.1 1.7 18.7 11.5 32 6 36 305 35.8 0.2 36.6 34.3 12/27/2005 11:10:00 14.6 1.7 19.1 10.3 14.3 1.7 18.7 9.5 34 6 31 305 35.5 0.2 36.2 34.9 12/27/2005 11:20:00 16.5 1.7 20.2 11.8 16.2 1.7 19.9 11.8 33 5 36 305 35.7 0.4 36.6 34.3 12/27/2005 11:30:00 15.9 1.6 19.1 11.5 15.7 1.6 18.7 11.5 33 5 37 305 36.5 0.2 37.2 35.9 12/27/2005 11:40:00 14.2 1.5 17.9 10.3 14 1.5 17.2 10.3 30 6 34 305 36.7 0.2 37.2 35.6 12/27/2005 11:50:00 14.5 1.7 19.1 9.5 14.2 1.7 17.9 8.8 30 6 36 305 36.4 0.2 37.2 35.9 12/27/2005 12:00:00 15 1.8 19.9 10.7 14.6 1.7 19.1 10.7 30 6 13 305 35.7 0.2 36.6 35.3 12/27/2005 12:10:00 14.1 1.7 18.7 10.7 13.8 1.7 18.7 10.3 31 6 27 305 35.5 0.3 36.2 34.3 12/27/2005 12:20:00 14.3 2.1 18.3 9.5 14 2.1 18.3 9.5 32 6 32 305 35.9 0.4 36.9 34.6 12/27/2005 12:30:00 14.4 1.7 18.7 10.3 14 1.5 17.9 10.3 35 6 38 305 36 0.1 36.6 35.3 12/27/2005 12:40:00 15.7 1.8 19.9 10.7 15.4 1.7 19.5 10.7 34 6 28 305 36.1 0.1 36.6 35.6 12/27/2005 12:50:00 14.1 1.4 17.6 11.5 13.8 1.4 17.6 10.7 33 6 33 305 35.8 0.1 36.6 35.3 12/27/2005 13:00:00 15.2 1.4 18.3 11.8 14.8 1.4 18.3 11.5 33 5 35 305 35.4 0.4 36.2 33.9 12/27/2005 13:10:00 14.2 1.4 17.6 10.7 13.9 1.4 17.9 10.3 34 6 36 305 35.3 0.2 36.2 34.3 12/27/2005 13:20:00 13.6 1.5 18.7 9.9 13.3 1.5 18.7 9.9 34 5 32 305 35.3 0.2 36.6 34.6 12/27/2005 13:30:00 13.3 1.5 17.6 9.9 13 1.5 17.6 9.5 30 6 37 305 34.4 0.5 35.6 33.3 12/27/2005 13:40:00 14.4 1.5 17.9 10.3 14 1.5 17.9 9.5 33 6 30 305 34.1 0.4 35.3 32.6 12/27/2005 13:50:00 15.2 1.5 19.1 11.5 14.8 1.5 19.1 10.7 32 6 38 305 33.7 0.3 34.9 32.6 12/27/2005 14:00:00 14.5 1.8 18.7 9.9 14.3 1.7 18.3 9.5 34 6 41 305 33.1 0.2 33.9 32.6 12/27/2005 14:10:00 13.8 1.5 17.2 10.3 13.5 1.5 16.8 9.9 35 7 26 305 33 0.2 34.9 32.3 12/27/2005 14:20:00 13.8 1.5 17.9 10.3 13.6 1.5 17.2 10.3 35 6 37 305 32.6 0.4 34.9 31.7 12/27/2005 14:30:00 15.1 1.5 19.1 11.5 14.8 1.5 18.7 11.5 34 6 33 305 32.1 0.3 34.3 31 12/27/2005 14:40:00 14.9 1.7 18.7 10.3 14.7 1.7 19.1 9.9 35 5 29 305 32.4 0.2 33.3 31.7 12/27/2005 14:50:00 14.6 1.6 18.3 11.1 14.3 1.5 17.6 10.7 34 5 35 305 32.7 0.4 33.3 31.4 12/27/2005 15:00:00 14.6 1.5 18.7 10.3 14.4 1.7 19.1 10.3 37 5 32 305 33 0.2 33.6 32 12/27/2005 15:10:00 13.8 1.8 18.7 9.9 13.5 1.9 18.7 9.5 36 5 34 305 33.2 0.2 33.9 32.3 12/27/2005 15:20:00 13.3 1.6 18.7 9.1 13.1 1.7 18.3 8.4 34 7 43 305 33.3 0.1 33.9 33 12/27/2005 15:30:00 12.6 1.4 15.6 9.1 12.3 1.5 15.6 8.4 32 6 30 305 33.1 0.3 34.3 32.6 12/27/2005 15:40:00 11.9 2.5 18.7 8.4 11.5 2.5 18.3 8 35 6 29 305 33.3 0.6 35.9 32 12/27/2005 15:50:00 13.4 1.5 17.2 9.5 13.2 1.5 17.2 9.5 35 7 27 305 35.8 1 39.3 27.6 12/27/2005 16:00:00 13.5 1.7 17.2 9.5 13.2 1.7 16.8 9.1 35 6 39 305 36.8 0.5 39.3 36.2 12/27/2005 16:10:00 12.1 1.8 15.6 8 11.8 1.8 16.4 7.6 35 6 32 305 37.5 0.4 39.6 36.6 12/27/2005 16:20:00 12.6 1.2 15.6 9.9 12.3 1.2 15.3 8.4 34 6 35 305 38.4 0.2 38.9 37.9 12/27/2005 16:30:00 12.5 1.7 16.8 8.8 12.3 1.7 16.8 8.4 33 6 32 305 38.5 0.5 39.6 37.6 12/27/2005 16:40:00 13.3 1.3 16.4 9.9 13.1 1.3 15.6 9.5 33 6 32 305 39.4 0.1 40 38.9 12/27/2005 16:50:00 13.7 1.4 17.2 9.9 13.3 1.4 16.8 9.5 34 5 35 305 39.5 0 40 39.3 12/27/2005 17:00:00 13.3 1.2 16.8 9.9 13 1.2 16.8 10.3 35 6 34 305 39.3 0 39.6 38.9 12/27/2005 17:10:00 13.7 1.3 16.8 10.7 13.6 1.4 16.4 10.3 35 5 32 305 38.4 1.1 39.6 35.3 12/27/2005 17:20:00 14.8 1.8 19.5 10.7 14.6 1.8 19.5 10.3 33 6 35 305 36.7 1.3 39.3 32.6 12/27/2005 17:30:00 16.6 1.2 19.5 13 16.4 1.2 19.9 13.3 31 5 22 305 35 1.2 36.9 31.7 12/27/2005 17:40:00 15.7 1.7 19.9 12.2 15.4 1.7 19.9 11.1 31 6 30 305 35.3 1.6 37.6 30.4 12/27/2005 17:50:00 14.4 1.7 18.7 10.7 14.2 1.7 18.7 10.3 32 6 27 305 36 0.5 37.6 34.9 12/27/2005 18:00:00 14.1 1.5 18.3 9.9 13.9 1.5 17.6 10.3 32 6 24 305 36.5 0.1 37.2 36.2 12/27/2005 18:10:00 13.1 1.3 17.2 9.9 13 1.3 16.4 10.3 35 6 32 305 36.5 0.1 36.9 35.3 12/27/2005 18:20:00 14.4 1.3 17.2 9.9 14.2 1.3 17.2 10.3 34 5 35 305 36.7 0.1 37.2 36.2 12/27/2005 18:30:00 14.1 1.7 17.9 9.1 13.7 1.7 18.3 9.5 34 6 36 305 36.8 0 37.6 35.9 12/27/2005 18:40:00 12.8 1.5 17.2 9.1 12.6 1.5 16.4 9.1 31 5 30 305 36.7 0.1 37.2 35.9 12/27/2005 18:50:00 12.9 1.5 16.8 9.5 12.6 1.5 16.4 9.5 33 6 33 305 35.9 0.6 37.2 35.3 12/27/2005 19:00:00 13.6 1.4 17.2 10.3 13.4 1.4 16.8 9.5 32 5 37 305 36.1 0.6 37.6 34.9 12/27/2005 19:10:00 12.9 1.2 15.6 9.9 12.8 1.2 16.1 9.9 36 6 37 305 37.4 0 37.9 37.2 12/27/2005 19:20:00 13.6 1.4 16.8 10.3 13.3 1.4 16.8 9.9 33 5 28 305 37.2 0.2 37.9 35.9 12/27/2005 19:30:00 15.5 1.3 19.5 11.8 15.3 1.2 18.7 12.2 39 6 35 305 36.9 0.5 37.9 35.9 12/27/2005 19:40:00 17 1.4 20.2 13.3 16.9 1.5 20.2 13 39 5 38 305 37.2 0.1 37.9 36.2 12/27/2005 19:50:00 16.5 1.5 20.2 13 16.2 1.5 20.2 11.8 38 5 40 305 37 0 37.6 36.6 12/27/2005 20:00:00 14.3 1.5 18.3 10.7 14 1.6 18.3 10.7 36 6 30 305 37 0 37.6 36.6 12/27/2005 20:10:00 15.3 1.3 18.3 11.8 15.1 1.5 18.7 11.5 34 5 35 305 36.5 0.1 37.2 35.9 12/27/2005 20:20:00 14.6 1.2 17.2 11.5 14.2 1.3 17.2 11.1 33 5 32 305 36.4 0 36.9 35.3 12/27/2005 20:30:00 16 1.4 19.9 11.5 15.7 1.3 19.9 12.6 37 5 31 305 36.4 0.1 36.9 35.3 12/27/2005 20:40:00 15.8 2 20.2 10.7 15.4 2 19.9 11.1 36 5 31 305 36.4 0.1 36.9 34.6 12/27/2005 20:50:00 16.1 1.6 19.5 12.6 15.6 1.6 19.5 11.8 34 5 31 305 33.6 5 37.2 12.1 12/27/2005 21:00:00 15.7 1.4 19.5 12.2 15.4 1.5 19.1 11.8 35 5 39 305 35.4 1.2 37.6 33.3 12/27/2005 21:10:00 15.4 1.4 19.1 11.8 15.1 1.4 18.7 11.1 37 6 39 305 34.4 0.2 35.3 33.9 12/27/2005 21:20:00 16.4 1.7 19.9 12.2 16.1 1.7 19.9 12.2 38 6 41 305 34.1 0.2 34.9 33.3 12/27/2005 21:30:00 14.5 1.3 17.6 11.8 14.2 1.3 17.6 11.5 36 5 30 305 33.1 0.6 34.3 31 12/27/2005 21:40:00 16.2 1.4 19.1 12.2 15.7 1.5 18.7 11.5 32 5 30 305 32.5 0.9 33.6 29.5 12/27/2005 21:50:00 15.2 1.6 19.1 11.8 14.8 1.5 18.7 11.1 33 5 31 305 24 3.5 31.7 19 12/27/2005 22:00:00 16.1 1.5 20.2 13 15.9 1.5 19.9 13 33 5 31 305 13.2 3.1 21 6.9 12/27/2005 22:10:00 16.3 1.5 19.9 12.6 16 1.5 19.9 11.8 34 5 35 305 17.7 3.8 22.2 9.5 12/27/2005 22:20:00 17.2 1.3 20.6 13.7 17 1.3 20.2 13.3 35 4 45 305 22.6 0.6 24.3 21.6 12/27/2005 22:30:00 17 1.6 21.4 13.7 16.7 1.5 20.2 13.3 35 5 35 305 24.8 0.5 26.1 24 12/27/2005 22:40:00 15.8 1.5 19.9 11.8 15.5 1.4 19.1 12.2 33 5 35 305 25.8 0.3 26.7 24.9 12/27/2005 22:50:00 15.9 1.6 19.5 11.8 15.7 1.6 19.9 11.5 34 5 39 305 25.6 0.4 26.7 24.6 12/27/2005 23:00:00 16.6 1.5 20.2 12.2 16.2 1.5 19.9 12.6 33 6 33 305 25.6 0.4 26.7 24.3 12/27/2005 23:10:00 16.2 1.5 19.5 12.6 15.9 1.5 19.1 12.2 32 5 29 305 24.3 2.3 26.7 17.9 12/27/2005 23:20:00 16.3 1.3 19.5 13 16 1.3 19.9 12.6 33 5 37 305 9.3 2.9 20.4 3.9 12/27/2005 23:30:00 15.1 1.5 19.1 11.5 14.9 1.5 17.9 11.1 35 6 30 305 5.7 1.2 8.7 1.5 12/27/2005 23:40:00 16.5 1.7 20.2 12.6 16.1 1.5 19.5 12.6 34 5 30 305 0.2 4 6.9 -8.4 12/27/2005 23:50:00 16.2 1.7 20.2 11.8 15.9 1.8 20.2 12.2 35 5 36 305 -9.3 3.4 -3.1 -14.6 12/28/2005 00:00:00 16.7 1.4 20.6 13.3 16.3 1.5 20.2 13 36 5 36 305 -12.2 3.1 -5.6 -14.6 12/28/2005 00:10:00 16.8 1.6 20.2 13 16.7 1.7 21 12.2 36 6 35 305 -5.1 1.1 -2.7 -7.9 12/28/2005 00:20:00 16.5 1.4 19.5 13.3 16.3 1.5 19.5 12.2 37 5 36 305 -2.3 9.9 11.3 -14.6 12/28/2005 00:30:00 16.3 1.7 20.2 11.5 16 1.7 19.5 10.7 36 5 39 305 10.1 1.9 13.4 4.4 12/28/2005 00:40:00 16.6 1.4 20.6 12.6 16.1 1.4 20.2 12.6 33 5 32 305 13.8 1.7 17.6 10.8 12/28/2005 00:50:00 16.2 1.5 20.2 13 15.8 1.5 19.9 12.6 35 5 35 305 18.2 2.7 24 13.7 12/28/2005 01:00:00 16.1 1.5 19.5 12.2 15.8 1.5 19.1 11.8 35 5 36 305 19.9 1.5 23.7 15.3 12/28/2005 01:10:00 15.5 1.7 19.1 11.1 15.3 1.7 19.5 10.7 36 5 35 305 19.2 1.2 21.9 16.5 12/28/2005 01:20:00 16.8 1.4 19.9 12.6 16.4 1.5 19.1 13 34 4 40 305 22 1.2 24.3 18.7 12/28/2005 01:30:00 15.3 1.6 19.1 11.5 15 1.6 18.7 11.1 33 5 32 305 21 0.8 22.5 18.1 12/28/2005 01:40:00 15.9 1.5 19.9 12.2 15.5 1.5 19.1 11.8 32 5 41 305 21.3 1.1 23.7 17.9 12/28/2005 01:50:00 15.7 1.9 19.5 11.5 15.3 1.9 19.9 11.1 33 5 34 305 24 1 27.3 22.2 12/28/2005 02:00:00 15.7 1.5 18.7 11.1 15.3 1.5 18.7 12.2 33 5 26 305 27 0.4 28.2 24.6 12/28/2005 02:10:00 15.3 1.9 19.5 10.3 14.8 1.8 19.5 9.9 32 6 31 305 27.4 0.7 29.5 24.6 12/28/2005 02:20:00 16.2 1.5 19.9 12.6 15.9 1.4 19.9 12.6 32 5 34 305 29.2 0.4 30.4 27.9 12/28/2005 02:30:00 16.1 1.9 20.2 11.5 15.7 1.9 20.2 11.1 33 6 35 305 30.3 0.9 32 26.7 12/28/2005 02:40:00 16.2 1.7 20.2 11.5 15.8 1.7 19.9 11.1 35 5 30 305 29.7 0.5 30.7 28.5 12/28/2005 02:50:00 15.7 1.6 19.5 12.2 15.3 1.7 19.5 11.1 33 6 33 305 29.5 0.5 30.7 27.9 12/28/2005 03:00:00 15.8 1.7 19.5 11.8 15.5 1.8 19.5 11.1 34 5 23 305 29.7 0.4 31 27.9 12/28/2005 03:10:00 14.6 1.8 19.1 10.3 14.1 1.8 19.1 10.3 35 6 28 305 29.9 0.5 31.7 28.5 12/28/2005 03:20:00 15.2 1.5 19.1 10.7 14.9 1.3 17.9 11.5 33 5 39 305 27.5 3.2 30.7 21.6 12/28/2005 03:30:00 15.4 1.4 19.1 12.2 14.9 1.4 18.3 11.8 33 6 31 305 23.3 2.3 28.8 19.6 12/28/2005 03:40:00 16.4 1.5 19.9 12.2 16.2 1.5 19.5 12.2 32 5 33 305 27.2 0.3 28.5 24.9 12/28/2005 03:50:00 16.8 1.6 20.6 12.6 16.4 1.5 19.9 12.6 33 5 34 305 27.4 0.8 29.8 22.5 12/28/2005 04:00:00 16.5 1.5 20.2 12.6 16.2 1.5 19.5 12.2 36 5 36 305 27.8 0.5 29.2 24 12/28/2005 04:10:00 16.6 1.4 19.5 12.6 16.3 1.3 19.1 12.6 33 5 33 305 28.9 1.1 31.4 26.4 12/28/2005 04:20:00 17 1.5 20.6 13 16.6 1.5 20.2 12.6 34 5 33 305 28.1 0.3 29.8 27.3 12/28/2005 04:30:00 16.8 2 20.6 11.1 16.4 1.9 20.6 10.7 32 5 31 305 28.2 0.7 30.4 24 12/28/2005 04:40:00 17.5 1.5 20.6 13.7 17 1.6 20.6 13 32 5 31 305 28.5 0.8 30.7 27 12/28/2005 04:50:00 17.3 1.8 21.4 12.6 16.9 1.8 21 12.6 33 5 30 305 28 0.2 28.5 26.7 12/28/2005 05:00:00 16.4 1.9 21.4 13 16 1.8 20.2 12.2 33 6 33 305 27.9 0.2 28.8 26.7 12/28/2005 05:10:00 15.5 1.6 19.5 11.8 15.1 1.6 19.9 11.5 33 6 37 305 27.9 0.2 28.5 27 12/28/2005 05:20:00 16.2 1.9 20.2 11.1 15.8 2 19.9 11.1 32 6 36 305 27.6 0.8 28.8 23.1 12/28/2005 05:30:00 16.7 1.8 20.6 12.2 16.2 1.9 20.2 11.5 32 6 28 305 27.8 0.5 29.2 26.1 12/28/2005 05:40:00 15.5 2.1 20.6 11.1 15.2 2 20.2 10.7 32 5 31 305 28.1 0.1 29.2 26.4 12/28/2005 05:50:00 16 1.8 20.2 11.1 15.7 1.7 19.5 11.5 32 6 32 305 28.2 0.4 29.2 24.9 12/28/2005 06:00:00 17.6 1.5 20.6 13.7 17.2 1.4 21 13.3 32 5 34 305 28.5 0.3 29.5 26.7 12/28/2005 06:10:00 16.8 1.3 20.2 13 16.3 1.4 19.5 13 32 5 31 305 28.5 0.2 29.8 27.3 12/28/2005 06:20:00 17.5 1.7 22.6 13 17 1.8 22.1 12.2 31 5 30 305 28.5 0.2 29.5 27 12/28/2005 06:30:00 17.4 2.2 21.8 11.8 17 2.1 22.1 12.2 29 5 25 305 29.6 0.7 31 27.3 12/28/2005 06:40:00 17.6 1.8 21.8 12.6 17.1 1.8 21.4 12.2 29 5 34 305 30 0.3 31 28.5 12/28/2005 06:50:00 16.8 2.2 22.1 12.2 16.7 2.1 21.4 11.8 32 5 38 305 29.9 0.2 31 29.2 12/28/2005 07:00:00 18 2.1 22.6 11.8 17.5 2.1 21.8 11.8 32 6 26 305 29.9 0.7 31.4 25.2 12/28/2005 07:10:00 17.5 2.2 22.1 12.2 17.1 2 21.8 11.8 30 6 28 305 30 0.6 31 26.1 12/28/2005 07:20:00 17.9 2.2 22.6 12.6 17.2 2 21.8 11.8 31 5 22 305 29.7 0.9 31.4 26.7 12/28/2005 07:30:00 17 1.7 21 13.3 16.6 1.7 21.8 13 30 6 26 305 29.3 1.1 31.4 26.1 12/28/2005 07:40:00 17.9 1.7 22.1 13 17.5 1.7 21.4 13 31 5 33 305 29.4 1 30.7 24.9 12/28/2005 07:50:00 16.7 1.9 22.1 13 16.2 1.9 21.4 12.2 30 6 25 305 29.7 1.3 31.7 24.3 12/28/2005 08:00:00 17.4 1.8 21.8 12.2 17.1 1.7 21 12.6 32 6 21 305 29.3 1.6 31.4 25.2 12/28/2005 08:10:00 15.8 1.9 21 11.1 15.4 1.8 20.2 11.8 31 6 25 305 29.3 1.5 31.4 25.5 12/28/2005 08:20:00 17.5 1.9 22.9 13 17 1.9 22.6 12.6 31 6 31 305 29.9 1.4 31.7 25.2 12/28/2005 08:30:00 16 2.1 21.8 11.8 15.5 2 22.1 11.8 29 6 36 305 29.5 1.7 31.4 24.9 12/28/2005 08:40:00 17 2 21.4 11.5 16.6 1.8 21 12.2 30 6 28 305 29.6 1.4 31.4 25.2 12/28/2005 08:50:00 16.5 2.5 23.7 10.7 16 2.5 22.6 11.1 34 6 31 305 29.8 1.5 31.7 25.5 12/28/2005 09:00:00 17.4 2.2 21.8 12.6 17.1 2.2 22.1 11.8 33 5 39 305 30.2 1.5 33.3 25.5 12/28/2005 09:10:00 18.3 1.9 22.6 12.6 17.8 1.8 22.6 13 32 6 28 305 30.2 1.2 33.3 25.8 12/28/2005 09:20:00 17 1.7 21.8 13 16.7 1.7 21.8 12.2 31 6 36 305 30.4 1.4 33.3 26.1 12/28/2005 09:30:00 16.6 1.7 20.2 12.6 16.1 1.7 19.9 11.8 32 6 34 305 33.6 3.8 40 25.5 12/28/2005 09:40:00 17.5 1.9 22.6 12.2 17.1 1.8 22.6 11.8 34 6 35 305 35 2.9 39.6 27.3 12/28/2005 09:50:00 17.1 1.7 21.8 12.6 16.7 1.7 21 12.2 34 5 35 305 36.2 3.1 41 25.2 12/28/2005 10:00:00 18.4 1.5 22.6 14.9 17.9 1.6 22.1 14.1 34 6 31 305 38.2 2.6 41.3 27.3 12/28/2005 10:10:00 16.9 1.9 21.4 11.8 16.6 1.8 20.2 11.5 32 6 22 305 37.7 1.9 40 28.8 12/28/2005 10:20:00 16.3 2.3 21 11.5 15.9 2.3 21.4 11.5 33 7 35 305 38 1.8 40 27.9 12/28/2005 10:30:00 18.1 2.2 22.6 12.2 17.9 2.2 22.1 11.8 32 6 35 305 37.6 3.5 41 24.6 12/28/2005 10:40:00 19.4 1.7 23.7 14.5 18.8 1.8 24 14.1 31 6 32 305 38.3 1.5 41.3 24.6 12/28/2005 10:50:00 18.9 2 23.3 14.1 18.5 2 22.9 14.1 31 6 35 305 37.6 2.2 40.6 25.5 12/28/2005 11:00:00 18.8 2.3 23.3 12.6 18.3 2.2 22.6 12.6 30 6 27 305 35.6 3.2 38.6 24 12/28/2005 11:10:00 18.9 2.3 24.4 13.3 18.5 2.1 24 13.3 32 6 30 305 39.8 2.9 43.8 27.6 12/28/2005 11:20:00 19.1 2.3 24 13 18.7 2.3 23.7 12.6 33 5 34 305 40 0.8 41.3 38.3 12/28/2005 11:30:00 17.2 2.1 22.6 12.6 16.8 2.1 22.9 12.6 31 6 25 305 39.5 0.7 41.7 37.6 12/28/2005 11:40:00 17.1 1.9 22.1 13 16.6 1.9 21.8 12.6 32 6 28 305 38.9 1.2 40.6 34.3 12/28/2005 11:50:00 17.5 2 22.9 12.6 17.1 1.9 22.1 12.6 33 6 34 305 37.5 0.6 39.3 35.9 12/28/2005 12:00:00 15.9 1.6 21.4 12.2 15.7 1.6 20.2 11.1 33 7 42 305 37.7 0.7 39.3 35.3 12/28/2005 12:10:00 17.7 2 22.1 11.8 17.3 1.9 21.4 11.8 32 6 22 305 37.7 1.7 39.3 24 12/28/2005 12:20:00 18.4 1.9 23.3 12.6 18.1 1.8 22.1 12.2 31 6 30 305 39.1 1.4 40.6 27.6 12/28/2005 12:30:00 18 2.3 23.3 12.6 17.7 2.2 23.3 11.8 31 6 34 305 38 0.5 39.6 35.9 12/28/2005 12:40:00 18.9 1.9 23.3 13.7 18.3 1.8 23.3 13.7 32 6 30 305 38.7 0.5 39.6 37.9 12/28/2005 12:50:00 17.7 2 23.3 13.7 17.2 1.9 23.3 13 33 6 31 305 36.8 1.8 38.3 30.1 12/28/2005 13:00:00 17.9 1.8 22.1 13.3 17.4 1.7 22.1 12.6 32 5 30 305 33 1.2 35.6 29.8 12/28/2005 13:10:00 15.9 1.6 19.5 11.8 15.6 1.4 19.1 12.2 32 6 24 305 31.7 0.9 33.3 28.5 12/28/2005 13:20:00 17.7 2.3 23.7 12.6 17.4 2.1 22.6 12.6 31 6 31 305 30.6 0.8 32 28.5 12/28/2005 13:30:00 18 1.8 22.6 13 17.5 1.9 22.1 13 31 6 42 305 35.6 2.4 37.9 28.2 12/28/2005 13:40:00 17.6 2.1 22.1 12.6 17.2 2 22.6 12.2 30 6 30 305 37.2 1.1 38.3 25.5 12/28/2005 13:50:00 18.3 2.2 22.9 12.6 17.8 2.1 23.3 12.6 31 6 19 305 37.8 0.5 38.9 34.6 12/28/2005 14:00:00 18.4 2 22.6 13 17.8 1.9 21.8 13 31 6 33 305 38 0.4 38.6 36.2 12/28/2005 14:10:00 18.5 1.8 22.6 13 17.9 1.7 21.4 13.7 29 5 42 305 38.3 0.1 38.9 37.6 12/28/2005 14:20:00 18.4 1.7 22.1 13.3 18.1 1.7 22.1 13.7 31 6 29 305 37.5 0.3 38.3 36.2 12/28/2005 14:30:00 17.3 2.1 22.1 12.6 16.9 2 21.8 11.5 29 5 37 305 37 0.6 39.6 31.7 12/28/2005 14:40:00 16.8 1.8 22.1 12.2 16.3 1.9 21.8 11.8 29 6 35 305 40 0.4 40.6 37.6 12/28/2005 14:50:00 18 2.1 22.1 11.8 17.4 2.1 22.1 11.5 32 6 38 305 39.4 0.4 40.3 38.6 12/28/2005 15:00:00 19.3 2.1 23.7 13.3 18.8 2.2 23.7 13.7 30 5 24 305 38.9 0.2 39.6 38.6 12/28/2005 15:10:00 18.1 2.1 22.1 12.6 17.6 1.9 21.8 11.8 32 5 31 305 38.8 0.3 39.6 37.9 12/28/2005 15:20:00 17.4 1.8 22.6 13 16.9 1.9 22.6 12.6 30 6 35 305 37.2 1.5 38.9 19.6 12/28/2005 15:30:00 17.6 2 22.1 13 17.2 2 21.4 13 31 6 20 305 37.1 0.6 38.3 34.3 12/28/2005 15:40:00 17.9 2.1 22.6 13.7 17.5 2.1 22.9 12.6 33 6 36 305 36.9 3.1 38.6 13.2 12/28/2005 15:50:00 18.4 2.1 22.9 13.3 17.9 2 23.3 12.6 33 6 32 305 34.9 1.2 37.6 27.3 12/28/2005 16:00:00 17.7 2 22.9 12.6 17.2 2 22.1 12.2 32 6 34 305 35.3 0.8 36.6 27.6 12/28/2005 16:10:00 18.2 1.9 22.6 13 17.8 1.8 22.1 13.3 33 6 31 305 35.8 1.1 37.6 30.7 12/28/2005 16:20:00 17.2 1.7 22.1 13 16.8 1.7 22.6 13.3 34 7 32 305 34.7 0.8 35.9 31 12/28/2005 16:30:00 17.1 2.2 22.6 12.2 16.6 2.1 22.1 12.6 33 6 35 305 34.5 0.7 35.9 30.7 12/28/2005 16:40:00 17.6 1.9 21.8 13 17.1 1.7 21.4 13 33 6 35 305 35.7 1.3 37.2 28.2 12/28/2005 16:50:00 16.9 2 22.1 11.8 16.6 1.9 21.8 11.8 32 6 28 305 36.7 0.3 37.6 35.9 12/28/2005 17:00:00 17.3 2.5 22.9 11.8 16.9 2.5 23.7 11.5 31 6 35 305 36.6 0.2 37.6 35.9 12/28/2005 17:10:00 17 2.6 22.9 11.5 16.6 2.4 22.9 11.1 32 6 27 305 37.2 0 37.9 36.9 12/28/2005 17:20:00 17.8 2.4 22.1 12.2 17.4 2.4 22.1 12.2 33 6 21 305 37.1 0 37.6 35.9 12/28/2005 17:30:00 18.2 2.5 24.8 12.6 17.7 2.4 24 12.2 31 6 30 305 35.8 0.9 37.2 33.6 12/28/2005 17:40:00 17.2 2.3 22.1 12.2 16.9 2.2 22.6 11.8 31 6 35 305 32.2 8 37.6 3.9 12/28/2005 17:50:00 17.5 2 22.6 13.3 16.9 1.9 22.6 12.6 31 6 34 305 24.9 2.3 28.5 17.3 12/28/2005 18:00:00 18.3 1.7 23.7 13.3 17.8 1.7 23.7 13 30 6 31 305 28.5 0.4 29.8 25.5 12/28/2005 18:10:00 17.4 1.7 21.4 13.3 17 1.7 21.4 13 31 6 32 305 30.6 0.9 31.7 27.3 12/28/2005 18:20:00 17.1 2.2 22.9 12.2 16.7 2 21.4 11.8 30 6 29 305 28.1 3.2 31.7 21.3 12/28/2005 18:30:00 18.5 2 23.7 13.3 17.9 1.9 22.6 12.6 31 5 28 305 30 1.4 31.4 26.1 12/28/2005 18:40:00 19.2 1.8 23.3 14.5 18.8 1.7 22.6 14.1 32 6 33 305 29.4 1.6 31 25.5 12/28/2005 18:50:00 18 2.1 22.6 12.6 17.6 2 22.1 12.6 33 6 30 305 27.9 1.8 31.7 25.8 12/28/2005 19:00:00 17.8 1.6 21.8 13.7 17.3 1.6 21.4 13 33 6 29 305 28.5 1.8 31.7 26.7 12/28/2005 19:10:00 17.8 2.2 24 12.2 17.3 2.2 23.7 12.2 33 6 35 305 28.5 1.8 31.4 26.4 12/28/2005 19:20:00 18.5 2.1 23.3 14.1 18 2 22.9 13.7 32 6 35 305 28.1 1.8 31 25.8 12/28/2005 19:30:00 18.3 2 23.3 13.3 17.9 1.9 22.6 12.6 33 5 30 305 27.6 1.5 30.7 25.5 12/28/2005 19:40:00 19.3 1.9 23.3 13 18.8 1.9 23.3 13 33 5 28 305 29.7 1.7 34.3 26.7 12/28/2005 19:50:00 18.3 2 23.3 13.7 17.8 2 23.3 12.2 33 5 37 305 35.6 0.7 36.9 33.9 12/28/2005 20:00:00 19.3 2.1 23.7 14.9 18.9 2.2 24.4 13.3 33 5 40 305 36.5 0.3 37.2 35.3 12/28/2005 20:10:00 18.6 2.1 24 14.1 18.4 2 23.7 12.6 35 6 30 305 36.9 0 37.2 35.3 12/28/2005 20:20:00 19.3 1.8 23.3 15.3 18.8 1.7 23.3 14.9 35 5 25 305 37.1 0.3 38.6 36.6 12/28/2005 20:30:00 18.2 2.2 24 13.3 17.9 2.1 24 13.7 35 5 37 305 38.2 0 38.6 37.9 12/28/2005 20:40:00 18.2 2.3 23.7 13 17.7 2.3 23.3 13 34 6 40 305 38.4 0 38.9 37.9 12/28/2005 20:50:00 19.4 2 23.7 14.1 18.8 1.9 23.3 14.1 33 6 42 305 38 0.2 38.6 37.6 12/28/2005 21:00:00 19.3 2.2 23.7 14.5 18.7 2 23.3 14.1 32 5 32 305 38.2 0.4 39.3 37.2 12/28/2005 21:10:00 17.3 1.9 21.8 12.6 17 1.9 21.4 12.6 33 5 32 305 38.6 0.1 39.3 38.3 12/28/2005 21:20:00 18.3 1.4 21.4 14.5 17.8 1.5 21.8 13 34 5 33 305 38.2 0.5 38.9 35.9 12/28/2005 21:30:00 18.8 1.8 23.3 13.3 18.3 1.9 22.9 13.3 33 6 36 305 37.5 0.1 37.9 37.2 12/28/2005 21:40:00 18.6 1.7 22.6 13.3 18.1 1.8 22.6 13 33 5 25 305 37.7 0.1 38.3 37.2 12/28/2005 21:50:00 17.8 1.9 23.3 13 17.6 1.9 23.7 13.3 33 6 47 305 38.1 0 38.6 37.9 12/28/2005 22:00:00 17.5 2.2 22.1 11.8 17.1 2.3 21.8 10.7 33 5 43 305 38.6 0.1 38.9 38.3 12/28/2005 22:10:00 16.6 1.9 21 11.8 16.2 1.8 21 11.8 33 6 32 305 39.7 0.7 40.6 38.6 12/28/2005 22:20:00 16.6 2.1 21.8 12.6 16.1 2.1 22.1 11.8 32 6 36 305 40.4 0.5 42 40 12/28/2005 22:30:00 14.8 1.7 19.5 11.1 14.5 1.5 19.1 10.7 30 6 26 305 41.9 0.1 42.4 41.3 12/28/2005 22:40:00 16 1.7 19.9 12.2 15.6 1.7 19.5 11.8 28 6 23 305 42.5 0.2 43.1 42 12/28/2005 22:50:00 16.2 2 21.4 11.5 15.8 1.8 20.6 11.1 28 6 33 305 42.4 0.2 43.1 41.7 12/28/2005 23:00:00 18 1.8 22.1 13.7 17.5 1.8 22.6 13.3 28 6 30 305 42 0.1 42.7 41.7 12/28/2005 23:10:00 17.5 2 23.3 13.3 17.2 2 22.1 13 27 6 27 305 42.8 0.2 43.4 42 12/28/2005 23:20:00 18 2.2 23.3 13 17.6 2.2 22.9 12.6 28 6 23 305 42.6 0 43.1 42.4 12/28/2005 23:30:00 17.2 2.2 21.8 11.5 16.8 2.2 21.8 11.8 28 6 27 305 42.6 0.5 47.3 41.3 12/28/2005 23:40:00 17.6 2 22.1 13.3 17.3 2 22.6 12.6 29 6 30 305 42.2 1.2 47.7 40.3 12/28/2005 23:50:00 18.9 2.1 23.3 13.7 18.5 2 22.9 13.3 29 5 33 305 43.9 2 48.4 40.6 12/29/2005 00:00:00 18 2 22.9 13.7 17.7 1.9 22.6 13 31 6 26 305 43.2 1.9 48.8 39.6 12/29/2005 00:10:00 18.8 1.7 24 14.5 18.2 1.8 23.3 13.7 31 6 29 305 44.1 2.5 49.2 39.6 12/29/2005 00:20:00 19.8 2.1 24.8 14.9 19.3 2.1 25.2 14.1 33 6 24 305 43.2 2.6 48.8 29.8 12/29/2005 00:30:00 20.5 2.1 25.2 15.3 20 2.1 24.4 15.3 33 5 31 305 41.4 1.5 43.4 24 12/29/2005 00:40:00 19.2 2.4 25.2 14.5 18.8 2.4 24.8 14.1 32 6 31 305 42.9 1.2 44.5 36.6 12/29/2005 00:50:00 19.4 2.2 25.2 14.1 19 2.1 23.7 14.9 32 6 36 305 43.2 2.5 46.6 28.8 12/29/2005 01:00:00 19.3 2.1 24.8 14.5 18.9 2.1 24 13.3 33 6 32 305 45.2 0.9 46.6 36.2 12/29/2005 01:10:00 20 2.1 25.6 14.5 19.5 2.1 25.2 13.7 32 5 27 305 48.2 3.7 52.9 40 12/29/2005 01:20:00 19.3 1.9 25.2 14.9 18.8 1.9 24.8 14.5 33 6 35 305 51.3 3.2 52.9 39.6 12/29/2005 01:30:00 19.4 2.1 24.8 14.1 19 2 24 14.5 33 6 30 305 50 3.1 52.1 39.6 12/29/2005 01:40:00 19.6 1.9 23.7 14.1 19 1.8 23.3 13.7 34 6 35 305 47.8 4.5 51.4 39.3 12/29/2005 01:50:00 19.4 2.4 25.6 14.9 19 2.4 25.6 13.7 33 5 37 305 48.9 3.7 51.4 38.9 12/29/2005 02:00:00 19.4 1.8 24 15.3 18.9 1.8 23.3 14.5 32 5 31 305 49.4 2.5 51.4 38.6 12/29/2005 02:10:00 19.1 1.7 23.7 14.5 18.6 1.7 22.9 14.9 35 6 40 305 49.1 1 50.3 38.3 12/29/2005 02:20:00 18.4 1.8 22.9 13.7 18.1 1.8 22.9 14.1 34 6 35 305 47.7 3.7 51.4 38.6 12/29/2005 02:30:00 19 2.1 23.7 13.3 18.6 2.2 24 12.6 34 6 39 305 44.9 6.2 51.8 35.9 12/29/2005 02:40:00 18.9 2 23.3 14.1 18.5 1.9 22.1 13.7 35 6 36 305 49.4 1.8 52.5 30.4 12/29/2005 02:50:00 19.7 1.8 23.7 15.3 19.2 1.7 23.3 14.9 37 5 30 305 50.2 1.6 51.4 32.6 12/29/2005 03:00:00 19.1 2.1 24 14.1 18.7 2 23.3 14.1 37 5 38 305 50.6 1 51.8 37.9 12/29/2005 03:10:00 18 1.8 22.6 12.6 17.6 1.8 22.1 13.3 34 6 36 305 51.5 0.8 52.9 37.9 12/29/2005 03:20:00 17.4 1.7 22.6 13.7 17 1.7 21.4 13 33 6 37 305 51.8 0.6 52.9 41 12/29/2005 03:30:00 19 2.4 24.8 13.7 18.5 2.4 24.8 13 32 6 30 305 51.7 0 52.5 51.4 12/29/2005 03:40:00 16.8 1.6 20.6 12.6 16.4 1.6 21 12.2 34 7 30 305 51.6 0.4 52.9 50.6 12/29/2005 03:50:00 17.8 2.2 22.1 13 17.4 2 22.6 12.2 34 6 29 305 51.6 0.5 52.9 50.6 12/29/2005 04:00:00 18 1.8 22.6 13 17.5 1.7 21.8 12.6 34 6 28 305 50.5 2.1 52.1 43.1 12/29/2005 04:10:00 18.9 1.7 22.6 13.3 18.4 1.7 22.6 13 33 6 32 305 48.2 1.9 50.6 42.7 12/29/2005 04:20:00 20.3 2 25.2 15.3 19.8 2 24.4 14.9 35 6 30 305 43.4 2.2 47.3 34.9 12/29/2005 04:30:00 19.1 1.8 23.3 14.1 18.7 1.8 22.9 14.1 34 5 26 305 44.6 1.8 46.3 32 12/29/2005 04:40:00 18.6 2 23.7 13.7 18.2 2 23.3 13.3 31 6 22 305 46.6 2.5 50.3 33.6 12/29/2005 04:50:00 18.1 2.3 23.3 12.6 17.5 2.2 22.1 12.6 31 5 29 305 48.6 2.6 50.6 33.6 12/29/2005 05:00:00 18.1 2.2 24.4 13 17.6 2.2 24 13.7 34 6 38 305 48.7 2.1 51.4 32.6 12/29/2005 05:10:00 20.4 2 26.8 15.6 19.9 2 25.2 15.3 35 6 30 305 41 8 51 30.1 12/29/2005 05:20:00 20.1 2 25.2 14.9 19.7 2 25.2 14.9 36 5 30 305 39.4 7 48.8 29.8 12/29/2005 05:30:00 20.3 2 25.6 14.9 19.8 2 25.2 14.5 33 5 30 305 44.4 2.4 47.7 30.4 12/29/2005 05:40:00 16.8 1.8 22.6 13 16.5 1.7 22.9 12.2 35 6 38 305 43.2 1.7 45.2 30.7 12/29/2005 05:50:00 17.9 2.7 23.7 11.8 17.5 2.7 23.7 11.1 34 5 33 305 43.4 1.7 46.3 31.7 12/29/2005 06:00:00 18.9 2.2 23.3 12.6 18.5 2.2 22.6 11.8 32 6 29 305 42 1.8 44.5 19.9 12/29/2005 06:10:00 19.2 2.1 24.4 13 18.9 2.1 23.3 13.7 32 5 39 305 43.5 1.5 45.5 26.7 12/29/2005 06:20:00 18.5 1.8 24 14.1 18.1 1.9 24.4 13.3 31 5 33 305 43.9 1 45.5 41.3 12/29/2005 06:30:00 17.7 2.1 23.3 13 17.3 2.1 22.9 12.6 32 6 31 305 43.8 0.8 45.5 40 12/29/2005 06:40:00 17.5 1.7 22.1 12.2 17.1 1.7 22.1 13 31 6 25 305 42.5 1.4 44.5 24.9 12/29/2005 06:50:00 17.3 1.8 22.1 12.6 16.9 1.7 22.1 12.6 32 6 32 305 42.2 1 44.5 37.9 12/29/2005 07:00:00 19.5 2 24.8 14.1 19.1 2 24 14.1 31 6 28 305 43.4 0.8 44.8 38.6 12/29/2005 07:10:00 18.9 1.8 22.9 14.5 18.5 1.9 22.9 14.1 32 5 37 305 43 1.4 45.2 25.5 12/29/2005 07:20:00 19.3 2.2 24.8 14.1 18.8 2.1 24 13 31 6 33 305 42.9 1.7 44.5 23.7 12/29/2005 07:30:00 20.7 1.8 25.2 15.6 20.3 1.8 25.6 15.3 34 6 36 305 43.2 0.8 44.5 32 12/29/2005 07:40:00 19.9 2.3 25.2 14.5 19.4 2.3 24.8 14.1 35 6 23 305 42.9 0.5 44.5 40.6 12/29/2005 07:50:00 20.3 2 24.4 15.6 19.9 2 24 15.3 34 6 30 305 43 0.9 44.5 33.3 12/29/2005 08:00:00 20.3 2.1 26 15.6 19.8 2.2 26 14.9 35 6 41 305 41.6 1.6 43.1 21.9 12/29/2005 08:10:00 20.4 2.3 25.2 14.5 20 2.2 25.2 14.9 35 6 37 305 41.4 0.7 43.4 33.9 12/29/2005 08:20:00 20.6 1.9 25.2 15.6 20 1.8 25.2 15.6 32 5 30 305 41.1 1.4 43.1 19.6 12/29/2005 08:30:00 19.3 2.4 24.8 13.3 18.9 2.2 24 13.3 31 6 24 305 40.6 1.4 42.7 19.6 12/29/2005 08:40:00 18.3 2 23.7 12.6 17.8 2 23.3 13 32 6 33 305 39.6 0.4 40.6 35.9 12/29/2005 08:50:00 18.9 2.2 24.4 13.7 18.5 2.2 24.4 12.6 32 5 36 305 40.1 1 42.7 36.6 12/29/2005 09:00:00 18.4 2 23.7 14.1 17.9 1.9 23.3 13 33 6 34 305 40.8 1.2 42.7 26.4 12/29/2005 09:10:00 19.8 2.7 25.2 13.3 19.4 2.6 25.2 13 34 6 37 305 41.1 0.9 42.7 38.3 12/29/2005 09:20:00 18.9 2.4 24 13.3 18.5 2.3 23.3 13.3 36 6 36 305 40.9 1.7 42.7 24.9 12/29/2005 09:30:00 19.1 2.3 24.4 13 18.6 2.4 23.7 11.8 35 6 22 305 41.2 0.9 42.7 35.9 12/29/2005 09:40:00 19.2 2 24 14.9 18.8 1.9 24 13.7 34 6 35 305 40 1 42 37.2 12/29/2005 09:50:00 20.2 2.5 26 15.3 19.7 2.5 25.6 14.1 34 6 34 305 40.9 1 42.7 38.6 12/29/2005 10:00:00 18.7 2.3 24.4 13.7 18.3 2.3 23.7 13.7 33 6 29 305 41.5 0.8 43.1 38.9 12/29/2005 10:10:00 19.8 2.3 26 14.5 19.3 2.2 25.2 14.5 32 6 27 305 41.8 1 43.1 33 12/29/2005 10:20:00 17.7 2.1 22.6 13 17.3 2.1 22.1 11.8 31 7 30 305 40.8 1.2 42.7 24.9 12/29/2005 10:30:00 18.6 2.4 23.7 12.2 18.1 2.2 22.9 12.6 31 6 26 305 41.2 0.8 43.1 36.9 12/29/2005 10:40:00 17.6 2.6 23.3 11.8 17.1 2.5 22.9 11.1 30 6 23 305 41.4 1.5 45.5 37.9 12/29/2005 10:50:00 19.3 1.7 23.3 15.3 18.7 1.6 22.6 15.3 30 6 31 305 43.2 0.9 45.2 38.9 12/29/2005 11:00:00 18.4 1.9 22.9 13.3 17.9 1.9 22.9 13.3 31 6 29 305 42.7 0.9 44.5 40 12/29/2005 11:10:00 16.3 1.7 21 12.2 15.9 1.8 20.6 11.1 34 6 39 305 43 1.4 44.8 25.8 12/29/2005 11:20:00 17.7 2.2 22.1 13.3 17.3 2.2 22.1 12.6 30 6 23 305 42.6 1.4 44.5 26.1 12/29/2005 11:30:00 15.9 2 22.6 11.5 15.5 1.9 22.1 11.1 32 7 28 305 41.9 1.4 44.5 21.9 12/29/2005 11:40:00 17.9 2.3 22.9 11.8 17.3 2.3 22.6 11.1 33 6 31 305 41.6 0.3 43.1 37.9 12/29/2005 11:50:00 17.5 2.6 23.7 11.1 17 2.6 23.7 11.5 32 6 29 305 41.8 0.3 43.4 40.6 12/29/2005 12:00:00 18.5 2 23.7 13 18.2 1.8 22.9 13 31 5 35 305 42.2 0.8 44.1 40.6 12/29/2005 12:10:00 17 2.2 21 10.3 16.7 2 22.1 10.3 31 6 29 305 42.7 1.2 44.5 27.3 12/29/2005 12:20:00 16.8 1.8 21.4 12.6 16.4 1.8 21.4 11.5 30 6 24 305 42.9 1.2 44.5 28.2 12/29/2005 12:30:00 17.1 1.8 21.4 13 16.8 1.8 21.4 13 32 6 27 305 43.2 1.2 44.5 27.6 12/29/2005 12:40:00 16 2.4 22.1 11.5 15.7 2.3 21 11.1 29 6 33 305 42.8 1.2 44.5 28.2 12/29/2005 12:50:00 17 2.5 21.8 11.5 16.7 2.3 21.8 10.7 33 5 29 305 42.4 0.9 44.1 39.6 12/29/2005 13:00:00 17.8 2.2 22.9 13 17.3 1.9 22.1 12.6 29 6 40 305 41.8 0.7 42.7 31.7 12/29/2005 13:10:00 17.1 2.2 22.6 11.8 16.7 2.2 22.6 11.8 31 6 28 305 43 0.9 44.5 40.6 12/29/2005 13:20:00 15.7 1.8 21 11.5 15.4 1.7 20.6 11.5 32 6 26 305 43 0.8 44.1 41 12/29/2005 13:30:00 15.4 1.7 19.9 11.1 15 1.6 19.1 11.1 30 6 36 305 42.3 0.7 44.1 40.6 12/29/2005 13:40:00 16.4 1.7 20.6 11.8 16.1 1.7 19.9 11.5 28 6 22 305 41.3 0.2 43.1 40.6 12/29/2005 13:50:00 16.6 1.7 20.6 13 16 1.6 20.6 12.6 29 6 33 305 42.5 0.9 43.8 40.3 12/29/2005 14:00:00 17 1.7 22.1 12.6 16.5 1.7 21.4 12.6 30 6 25 305 41.6 0.6 43.4 40.6 12/29/2005 14:10:00 17 1.7 20.6 12.6 16.5 1.7 20.6 11.8 32 6 28 305 42.5 0.9 43.8 35.9 12/29/2005 14:20:00 16.2 1.7 20.2 11.5 15.9 1.7 19.5 11.1 35 6 32 305 42.8 1 45.2 37.2 12/29/2005 14:30:00 16 1.6 19.9 12.2 15.8 1.5 19.5 12.2 35 5 37 305 42.9 0.9 45.5 40.6 12/29/2005 14:40:00 15.9 1.8 20.6 10.7 15.6 1.7 21.4 11.5 35 6 37 305 42.5 0.8 44.1 40.6 12/29/2005 14:50:00 17.3 2 22.6 12.2 17 2 22.6 11.8 35 5 35 305 42.5 1 44.8 37.9 12/29/2005 15:00:00 17.8 1.7 22.9 11.8 17.5 1.7 22.1 12.2 33 6 28 305 42.5 1 44.8 40 12/29/2005 15:10:00 18.5 1.8 22.9 13.7 18.1 1.8 22.6 13.7 32 5 28 305 42.5 1 44.8 40.3 12/29/2005 15:20:00 18.5 1.9 22.6 13.3 18 1.8 21.4 13.3 32 5 32 305 42.6 1.1 45.5 34.9 12/29/2005 15:30:00 18.4 2.1 22.6 12.6 17.8 2 22.1 13 31 6 31 305 43.4 1.5 47.3 35.9 12/29/2005 15:40:00 17.1 1.8 21.4 12.6 16.8 1.8 22.6 12.6 32 5 26 305 46.2 1.5 48.4 40.6 12/29/2005 15:50:00 17.2 2.2 21.8 11.8 16.7 2.1 21.8 11.8 31 6 33 305 46.9 1.2 48.1 28.8 12/29/2005 16:00:00 17.2 2.3 22.9 11.8 16.6 2.2 21.8 11.8 32 6 28 305 45.1 3.7 47.7 26.4 12/29/2005 16:10:00 17.3 2.4 22.1 11.5 16.7 2.4 21.4 11.5 32 6 35 305 45.2 1.5 47.3 36.2 12/29/2005 16:20:00 17.1 2.2 22.6 12.2 16.8 2 22.6 13.3 33 6 25 305 44.9 1.8 46.6 26.4 12/29/2005 16:30:00 18.7 1.7 22.6 13.3 18.2 1.7 22.6 12.6 32 6 29 305 45 1.5 46.6 24 12/29/2005 16:40:00 16.2 1.7 20.2 12.6 15.7 1.7 20.2 11.8 32 6 38 305 44.7 0.8 46.3 40.6 12/29/2005 16:50:00 15.1 1.9 20.2 10.7 14.9 1.8 19.9 10.3 23 7 24 305 44.2 1.5 45.5 27 12/29/2005 17:00:00 13.5 1.5 17.6 10.3 13.3 1.3 16.8 9.9 16 6 16 305 44.6 1.2 46.3 31 12/29/2005 17:10:00 13.2 1.2 16.4 9.1 13.2 1.3 16.1 9.1 15 5 16 305 44.7 1.9 45.5 21.6 12/29/2005 17:20:00 13 1.5 16.8 9.5 12.9 1.5 16.8 9.5 17 6 19 305 44.6 0.7 45.5 41.3 12/29/2005 17:30:00 13.4 1.5 16.8 9.5 13.3 1.5 16.4 9.9 16 5 18 305 44.1 0.6 45.2 42 12/29/2005 17:40:00 13.9 1.5 17.6 10.3 13.8 1.4 18.3 10.3 17 5 11 305 43.7 0.7 44.5 40.6 12/29/2005 17:50:00 14.5 1.5 18.3 11.1 14.2 1.4 17.9 11.1 18 5 12 305 43.8 0.9 45.2 39.3 12/29/2005 18:00:00 14.5 1.4 17.6 10.3 14.3 1.4 17.2 10.7 17 6 30 305 41 3.1 44.5 20.4 12/29/2005 18:10:00 15.1 1.3 18.3 10.7 15.1 1.3 18.3 11.1 17 5 12 305 41.8 2.5 43.8 32.6 12/29/2005 18:20:00 15 1.6 18.3 10.3 14.8 1.5 17.9 10.7 16 5 16 305 35.8 0.3 36.9 34.3 12/29/2005 18:30:00 15.9 1.3 19.1 12.2 15.8 1.3 18.7 12.2 18 5 17 305 36.7 0 37.2 36.2 12/29/2005 18:40:00 15.8 1.3 18.7 12.2 15.6 1.3 19.5 12.2 17 5 14 305 36.9 0 37.2 36.9 12/29/2005 18:50:00 15.6 1.5 19.1 11.5 15.4 1.5 19.1 11.5 18 5 14 305 37.2 0 37.6 36.6 12/29/2005 19:00:00 16.2 2 21.4 11.8 16 2 21 12.2 16 5 11 305 37.2 0 37.6 36.9 12/29/2005 19:10:00 16.5 1.5 20.2 13 16.4 1.5 20.2 13 17 5 13 305 38.4 3.1 47 36.6 12/29/2005 19:20:00 17.1 1.5 20.6 13.3 16.7 1.5 20.6 13.3 19 5 20 305 43.7 3.2 46.6 36.9 12/29/2005 19:30:00 15 1.7 19.1 11.1 14.9 1.7 19.5 10.7 21 6 19 305 43.1 4.4 47 34.6 12/29/2005 19:40:00 14.4 1.5 17.6 10.3 14.2 1.5 17.6 10.7 21 5 27 305 42.4 2.5 46.6 36.2 12/29/2005 19:50:00 15.4 1.5 18.7 11.8 15.2 1.5 18.7 11.5 19 5 22 305 42.9 2.8 46.3 36.9 12/29/2005 20:00:00 15.1 1.3 18.3 11.1 15 1.3 17.9 11.5 17 5 15 305 43 2.7 45.9 36.9 12/29/2005 20:10:00 14.8 1.7 18.3 10.7 14.6 1.6 17.6 10.7 18 5 15 305 43.7 2.3 45.9 36.9 12/29/2005 20:20:00 15.8 1.3 18.7 11.8 15.5 1.4 19.1 11.8 18 4 21 305 44.2 2.5 46.3 36.9 12/29/2005 20:30:00 15.5 1.7 19.1 11.1 15.3 1.7 18.7 11.5 19 5 24 305 44.4 1.8 46.6 36.9 12/29/2005 20:40:00 15.8 1.7 19.1 11.1 15.7 1.7 19.9 11.5 19 5 15 305 43.6 2.4 47 37.2 12/29/2005 20:50:00 15.6 1.5 18.7 11.8 15.4 1.5 18.7 11.5 19 5 16 305 44.8 2.4 47.7 37.2 12/29/2005 21:00:00 14.7 1.7 17.9 11.1 14.5 1.5 17.9 10.7 19 5 15 305 44.7 1.4 47 36.9 12/29/2005 21:10:00 15.4 1.7 18.7 11.5 15.2 1.7 18.7 11.5 19 5 18 305 44.7 2.5 46.6 35.3 12/29/2005 21:20:00 15.6 1.7 19.1 10.3 15.4 1.7 19.1 9.9 19 5 17 305 44.7 1.5 46.3 35.3 12/29/2005 21:30:00 15.6 1.5 19.5 11.5 15.3 1.5 19.1 11.8 19 5 16 305 45 0.9 45.9 34.9 12/29/2005 21:40:00 15 1.7 19.1 11.8 14.7 1.6 19.1 11.1 19 6 16 305 44.9 0.6 45.5 41 12/29/2005 21:50:00 16.1 1.4 19.1 12.6 15.9 1.4 19.5 12.2 20 5 17 305 44.3 1.8 45.5 33.3 12/29/2005 22:00:00 14.7 1.5 19.1 10.7 14.4 1.6 19.1 10.7 21 5 15 305 45.1 1.2 46.3 35.3 12/29/2005 22:10:00 14.8 2 19.5 10.3 14.7 1.9 19.1 10.7 21 5 21 305 44.9 0.4 46.3 42 12/29/2005 22:20:00 15.6 1.5 18.3 9.9 15.3 1.5 17.9 11.1 19 5 13 305 44.5 0.7 45.2 34.9 12/29/2005 22:30:00 14.2 2 19.5 9.5 14.1 2 18.7 9.5 19 5 18 305 44.3 0.3 45.2 41 12/29/2005 22:40:00 14.6 1.5 17.6 9.9 14.4 1.5 17.6 9.9 22 5 26 305 43.8 1 44.5 34.3 12/29/2005 22:50:00 15.2 1.5 18.3 11.8 15 1.5 18.3 11.5 20 5 15 305 43.9 1.9 45.5 34.6 12/29/2005 23:00:00 15.5 1.5 18.7 11.1 15.3 1.6 18.7 10.7 20 5 30 305 44.1 1 45.2 34.9 12/29/2005 23:10:00 14.7 1.6 19.5 11.5 14.5 1.5 18.3 11.1 21 5 26 305 43.9 1.8 45.2 34.9 12/29/2005 23:20:00 15.5 1.4 19.1 12.2 15.3 1.5 19.1 11.8 22 5 23 305 43.8 0.3 44.5 41.7 12/29/2005 23:30:00 15.5 1.5 19.1 11.8 15.1 1.5 18.3 11.5 19 6 14 305 43.5 0.9 44.1 34.6 12/29/2005 23:40:00 15.1 1.5 18.7 11.1 14.8 1.5 19.1 11.5 21 6 21 305 43.4 1.1 44.5 34.9 12/29/2005 23:50:00 15.4 1.6 19.9 11.5 15.3 1.6 19.5 11.5 21 5 16 305 43.9 0.6 44.5 34.9 12/30/2005 00:00:00 15.9 1.6 19.9 12.2 15.8 1.6 19.5 11.8 20 5 26 305 43.2 1.2 44.5 34.3 12/30/2005 00:10:00 16.2 1.5 19.1 11.5 15.9 1.5 19.1 11.8 21 5 23 305 35.4 0.2 35.9 33.3 12/30/2005 00:20:00 15.2 1.6 18.7 10.7 15 1.7 18.7 10.7 19 5 10 305 41.2 3.7 45.2 35.3 12/30/2005 00:30:00 14.8 1.3 17.9 11.5 14.6 1.5 18.3 10.3 22 5 30 305 43.4 1 44.8 35.3 12/30/2005 00:40:00 15 1.4 17.9 11.5 14.8 1.3 17.6 11.5 21 5 29 305 43 2.9 45.5 34.9 12/30/2005 00:50:00 14.1 1.5 17.9 10.7 13.9 1.5 18.3 10.7 20 5 20 305 43.9 1.6 45.5 35.3 12/30/2005 01:00:00 14.3 1.5 17.9 11.1 14.1 1.5 17.9 10.7 18 5 21 305 42.5 2 45.2 34.9 12/30/2005 01:10:00 15.4 1.5 18.7 11.8 15.2 1.5 18.7 11.8 20 5 26 305 42.1 1.6 44.1 34.6 12/30/2005 01:20:00 14.4 1.6 18.3 10.3 14.2 1.6 17.6 10.3 20 6 19 305 42.2 1.4 43.8 34.3 12/30/2005 01:30:00 14.2 1.5 17.9 9.9 14 1.4 17.6 9.9 22 5 18 305 41.8 2.8 44.5 35.9 12/30/2005 01:40:00 14.7 1.5 17.9 11.5 14.4 1.5 17.9 11.1 23 5 24 305 36.7 1.5 45.9 35.9 12/30/2005 01:50:00 15.8 1.7 19.9 11.5 15.4 1.7 19.5 11.1 21 5 19 305 44.4 1 46.6 36.9 12/30/2005 02:00:00 14.6 1.7 17.9 11.1 14.4 1.7 17.9 10.7 19 6 26 305 44.6 0.6 45.9 36.2 12/30/2005 02:10:00 14.4 1.5 17.6 9.9 14.1 1.4 17.2 10.3 19 5 19 305 45.7 1.1 47 41.7 12/30/2005 02:20:00 13.5 1.2 16.8 10.3 13.4 1.2 16.8 10.3 17 5 12 305 45.3 0.8 46.6 43.4 12/30/2005 02:30:00 12.8 1.3 16.8 9.1 12.6 1.3 16.1 9.1 18 5 17 305 46.3 0.5 47 40 12/30/2005 02:40:00 13 1.5 16.8 9.5 12.8 1.5 16.4 9.5 20 6 19 305 46.3 2.1 48.4 37.6 12/30/2005 02:50:00 14.3 1.5 17.6 10.3 14.1 1.7 17.6 9.9 18 5 20 305 46.1 1.8 47.7 37.9 12/30/2005 03:00:00 13.9 1.5 17.6 10.7 13.8 1.5 17.2 9.9 19 5 10 305 46.1 0.7 47.3 37.9 12/30/2005 03:10:00 14.2 1.5 17.6 9.1 13.9 1.5 17.6 9.5 16 5 12 305 45.8 2.2 48.1 37.9 12/30/2005 03:20:00 14.4 1.3 18.3 10.7 14.3 1.3 17.9 11.1 17 5 14 305 46 1.4 47.7 37.9 12/30/2005 03:30:00 14.5 1.6 17.9 10.3 14.2 1.7 17.9 10.3 18 5 21 305 45.5 1.5 46.6 37.9 12/30/2005 03:40:00 12.6 1.7 16.8 8.8 12.5 1.7 16.4 8.4 18 6 11 305 45.5 1.1 47.3 37.6 12/30/2005 03:50:00 14 1.8 17.6 9.5 13.8 1.7 17.9 9.5 17 5 15 305 45.5 0.8 47.3 37.6 12/30/2005 04:00:00 13.2 1.5 16.8 9.1 13.1 1.5 16.8 8.8 18 6 16 305 45.5 0 45.9 44.1 12/30/2005 04:10:00 13.6 1.5 17.2 9.1 13.5 1.5 17.2 8.8 16 5 17 305 45.1 1 46.3 37.2 12/30/2005 04:20:00 14.6 1.5 17.9 11.1 14.5 1.5 17.6 10.7 17 5 17 305 45.5 1.1 47.3 37.6 12/30/2005 04:30:00 13.7 1.4 16.8 9.9 13.6 1.4 17.9 10.3 17 6 20 305 45.5 1.4 47.3 37.9 12/30/2005 04:40:00 14.8 1.6 19.5 11.1 14.8 1.5 18.3 10.7 16 4 18 305 46.1 0.7 47.7 38.6 12/30/2005 04:50:00 15.3 1.5 18.7 11.5 15.1 1.5 18.7 11.5 16 6 14 305 45.5 1.7 47.7 38.3 12/30/2005 05:00:00 14.7 1.7 18.3 10.7 14.5 1.6 18.3 10.3 16 5 11 305 45.7 1.4 48.1 38.3 12/30/2005 05:10:00 14.7 1.7 19.1 10.7 14.4 1.7 19.5 10.3 19 6 17 305 45.9 1.4 47.7 38.3 12/30/2005 05:20:00 14.8 1.7 19.5 11.1 14.6 1.7 19.9 11.1 20 5 20 305 45.7 1.4 47.7 37.9 12/30/2005 05:30:00 14.5 1.5 17.9 10.3 14.4 1.5 17.9 10.7 20 5 22 305 45.7 1 47.3 37.9 12/30/2005 05:40:00 13.3 1.5 16.8 10.3 13.2 1.4 16.8 9.9 18 6 16 305 45.4 1.8 47.7 37.6 12/30/2005 05:50:00 13.7 1.8 18.3 9.1 13.5 1.8 18.7 9.5 19 5 16 305 45.4 2 47 37.2 12/30/2005 06:00:00 14.1 2 18.3 9.1 14 2.1 18.3 9.1 20 5 22 305 45.7 0.7 47 37.9 12/30/2005 06:10:00 14.6 1.5 17.6 9.5 14.4 1.6 17.6 9.9 18 5 18 305 45.8 1 47.3 37.9 12/30/2005 06:20:00 13.8 1.3 17.2 10.3 13.7 1.4 16.8 9.5 19 5 25 305 45.5 0.6 46.3 35.3 12/30/2005 06:30:00 14.4 1.6 18.7 9.9 14.1 1.5 17.6 9.5 20 6 23 305 45.5 0 45.9 44.5 12/30/2005 06:40:00 14.3 1.7 18.3 10.3 14.2 1.6 17.9 10.3 21 5 13 305 45.5 1.2 47.3 36.2 12/30/2005 06:50:00 14 1.2 17.6 11.1 13.8 1.3 17.9 10.7 21 6 28 305 45.7 1.9 47.3 35.3 12/30/2005 07:00:00 13.1 1.3 16.8 9.5 13.1 1.3 16.8 10.3 20 6 17 305 46 0 46.3 45.2 12/30/2005 07:10:00 13.9 1.4 16.8 9.9 13.8 1.4 16.8 9.5 19 5 13 305 45.7 0 46.3 45.5 12/30/2005 07:20:00 15 1.3 17.6 11.8 14.8 1.3 17.6 11.5 18 5 14 305 45.8 0.9 47 35.9 12/30/2005 07:30:00 14.7 1.3 17.6 11.1 14.4 1.3 17.6 11.5 18 5 25 305 45.5 2.1 48.4 35.3 12/30/2005 07:40:00 14.1 1.7 17.9 9.9 13.9 1.7 17.9 9.5 18 5 25 305 46.2 2.2 48.1 35.3 12/30/2005 07:50:00 14.2 1.6 17.9 10.7 14 1.6 18.3 10.3 19 5 16 305 46.3 1.1 47.7 37.9 12/30/2005 08:00:00 14.7 1.3 18.3 11.5 14.6 1.3 18.7 10.7 17 5 17 305 46.7 1.8 48.1 37.9 12/30/2005 08:10:00 13.9 1.5 18.3 10.7 13.8 1.5 17.9 10.7 20 5 23 305 46.6 2 48.4 37.9 12/30/2005 08:20:00 14.2 1.5 17.6 10.7 14.1 1.5 17.6 11.1 20 5 19 305 47 1.9 48.8 37.9 12/30/2005 08:30:00 13.3 1.3 17.6 9.9 13.3 1.4 17.2 9.5 19 5 22 305 47.1 1.2 48.1 37.9 12/30/2005 08:40:00 13.1 1.2 15.6 9.9 13 1.2 16.1 9.5 19 6 25 305 46.9 0.8 47.7 38.3 12/30/2005 08:50:00 13 1.3 16.4 10.3 12.9 1.4 16.4 9.9 19 5 20 305 46.4 1.3 48.1 37.9 12/30/2005 09:00:00 13 1.6 16.4 9.1 12.9 1.6 16.8 9.5 18 6 15 305 46.3 1.3 47.7 37.9 12/30/2005 09:10:00 13.7 1.5 17.6 9.5 13.6 1.5 17.2 9.9 19 5 19 305 46 0.8 47.7 37.9 12/30/2005 09:20:00 14.3 1.3 17.2 10.7 14.1 1.5 17.6 9.9 19 5 24 305 45.3 1.2 47 36.6 12/30/2005 09:30:00 12.6 1.7 16.4 8.8 12.6 1.7 17.6 8.4 18 5 11 305 45 1.9 47 36.9 12/30/2005 09:40:00 13.6 1.9 18.7 9.1 13.3 1.7 17.6 9.1 17 6 17 305 45 2.7 47.3 36.6 12/30/2005 09:50:00 13.9 1.6 17.2 9.5 13.9 1.7 17.2 9.5 18 5 17 305 45.8 1.8 47.7 36.2 12/30/2005 10:00:00 13.6 1.3 17.2 10.7 13.5 1.3 17.6 10.3 18 6 12 305 45.6 1.8 47.7 37.2 12/30/2005 10:10:00 14.9 1.5 17.9 11.1 14.8 1.5 17.9 11.1 16 5 16 305 46.2 1.5 47.7 37.9 12/30/2005 10:20:00 14 1.2 17.9 10.3 13.9 1.2 17.9 10.7 17 5 17 305 45.3 1.1 46.3 37.6 12/30/2005 10:30:00 14.2 1.6 17.9 10.3 14.1 1.7 17.6 10.7 17 5 12 305 45.5 1 46.6 37.6 12/30/2005 10:40:00 14.2 1.7 18.7 10.3 14 1.7 18.7 9.9 17 6 22 305 46.3 1.1 47.7 37.6 12/30/2005 10:50:00 14.5 1.3 17.2 10.3 14.3 1.4 16.8 10.7 16 5 19 305 46.2 1.4 47.3 37.2 12/30/2005 11:00:00 13.9 1.3 17.2 9.9 13.7 1.3 17.2 10.3 18 5 22 305 46.3 1 47.3 36.2 12/30/2005 11:10:00 13.8 1.5 17.2 9.5 13.6 1.4 17.2 10.3 18 5 17 305 43.9 2.1 47.7 36.6 12/30/2005 11:20:00 14.9 1.4 17.9 9.9 14.8 1.4 18.3 9.9 19 5 22 305 44.2 1.7 46.6 36.6 12/30/2005 11:30:00 14.4 1.6 18.3 10.3 14.2 1.5 18.3 11.1 17 5 16 305 44.5 1.2 46.6 34.9 12/30/2005 11:40:00 14.6 1.4 17.9 10.7 14.4 1.6 17.6 10.7 16 5 12 305 44.4 0.4 45.5 42.7 12/30/2005 11:50:00 13.9 1.2 16.4 11.1 13.8 1.3 16.4 8.8 20 5 19 305 40.6 1.1 44.5 38.9 12/30/2005 12:00:00 14 1.4 17.2 10.7 13.9 1.5 17.2 9.5 20 6 13 305 43.8 0.7 44.8 41 12/30/2005 12:10:00 14 1.7 18.3 10.7 13.8 1.6 17.6 9.9 19 5 20 305 44.4 1 46.3 38.6 12/30/2005 12:20:00 14.2 1.5 17.6 9.1 13.9 1.4 17.9 9.5 19 5 23 305 46 0.1 46.6 45.5 12/30/2005 12:30:00 14.3 1.4 17.9 10.7 14.2 1.5 17.6 10.3 19 5 16 305 46.7 0.3 47.3 45.9 12/30/2005 12:40:00 14.1 1.2 17.2 10.7 14 1.2 16.4 10.3 17 5 16 305 46.9 0 47.3 45.2 12/30/2005 12:50:00 13.6 1.4 16.8 9.5 13.3 1.4 16.4 9.5 18 5 22 305 46.9 0.6 47.7 40.6 12/30/2005 13:00:00 13.5 1.2 16.4 10.7 13.4 1.2 16.4 10.3 19 5 25 305 47.2 0 47.7 47 12/30/2005 13:10:00 13.9 1.3 17.6 10.7 13.8 1.3 17.2 10.3 19 4 25 305 46.2 1.8 47.7 40.3 12/30/2005 13:20:00 13.8 1.2 17.2 11.1 13.6 1.2 16.8 10.7 18 5 11 305 46.9 0.5 47.3 37.2 12/30/2005 13:30:00 14.2 1.2 17.2 10.3 14 1.3 17.6 10.7 21 5 16 305 46.8 0 47.7 45.9 12/30/2005 13:40:00 14.4 1.6 18.3 9.5 14.1 1.7 17.6 9.1 22 5 21 305 46.7 0 47.3 44.8 12/30/2005 13:50:00 14.5 1.1 17.6 11.8 14.2 1.2 17.9 11.8 22 5 19 305 46.3 0.2 47 44.5 12/30/2005 14:00:00 14.2 1.2 17.6 10.7 14 1.2 17.6 11.1 21 5 23 305 46 0.3 47 44.1 12/30/2005 14:10:00 12.4 1.3 16.4 9.5 12.3 1.3 16.4 9.1 19 5 17 305 46.1 0.3 47.3 44.1 12/30/2005 14:20:00 13.4 1.7 17.6 8.8 13.2 1.6 17.2 9.5 20 5 16 305 46.4 0.2 47.3 45.5 12/30/2005 14:30:00 12.9 1.4 16.1 8.8 12.6 1.4 15.6 9.1 23 5 20 305 46.3 0.8 47.3 37.2 12/30/2005 14:40:00 12.9 1.4 15.6 9.5 12.8 1.4 15.6 9.1 22 5 32 305 46.4 0.7 47.3 36.9 12/30/2005 14:50:00 12.2 1.1 14.9 9.5 12.1 1.1 14.9 8.8 21 5 18 305 46.3 0.3 47.3 44.5 12/30/2005 15:00:00 12.3 1.3 15.3 9.1 12.2 1.3 15.6 8.8 21 5 22 305 42.7 2.7 46.6 37.6 12/30/2005 15:10:00 12.4 1.2 15.3 9.5 12.4 1.2 15.3 9.5 19 5 22 305 42.3 1.1 44.5 38.9 12/30/2005 15:20:00 12.8 1 14.9 9.5 12.7 1 15.3 9.9 21 4 21 305 45.7 1.6 48.1 37.2 12/30/2005 15:30:00 11.8 1.1 14.5 9.1 11.7 1.1 14.5 8.8 18 4 16 305 46.7 0.1 47.7 45.5 12/30/2005 15:40:00 11.9 0.9 14.1 8.8 11.7 0.9 14.1 9.5 18 4 17 305 45.9 1.2 47.7 41.3 12/30/2005 15:50:00 11.5 0.9 13.3 8.8 11.4 1 14.1 9.1 17 4 18 305 46.6 0.3 47.3 44.8 12/30/2005 16:00:00 12 1 14.1 9.1 11.9 1 14.1 9.1 16 4 13 305 46.3 0.4 47.3 44.8 12/30/2005 16:10:00 13.4 1.3 16.4 9.1 13.4 1.3 16.8 8.8 14 4 15 305 46.1 0.9 47.3 41.3 12/30/2005 16:20:00 13.7 1.1 16.1 10.3 13.6 1.1 16.4 10.3 14 4 5 305 45.9 0.8 47 40 12/30/2005 16:30:00 13.3 1.2 16.1 9.9 13 1.2 16.4 9.9 17 5 13 305 46.2 0.4 47.3 43.8 12/30/2005 16:40:00 13.2 1.3 15.6 9.9 13.1 1.3 15.6 9.9 17 5 12 305 46.2 0.6 47.3 40.3 12/30/2005 16:50:00 14.1 1.2 17.2 11.1 14 1.2 16.8 10.7 19 5 18 305 45.8 1 47 35.9 12/30/2005 17:00:00 14.1 1.3 17.6 10.7 14 1.2 16.8 11.1 17 5 22 305 46.7 0.6 48.1 43.4 12/30/2005 17:10:00 14.6 1.4 17.6 10.7 14.4 1.5 18.3 10.3 18 5 12 305 47.1 0.1 47.7 45.5 12/30/2005 17:20:00 14.2 1.4 17.6 11.1 14.1 1.3 17.2 11.1 18 5 14 305 47.2 0.1 48.1 46.3 12/30/2005 17:30:00 14.2 1.3 17.6 11.1 14.1 1.3 17.6 10.7 17 5 18 305 46.2 0.9 47.3 43.8 12/30/2005 17:40:00 12.7 1.2 14.9 9.5 12.6 1.2 15.3 9.5 20 5 18 305 46.8 0.2 47.7 45.2 12/30/2005 17:50:00 12 1.2 14.9 9.1 11.9 1.3 15.6 9.5 21 5 26 305 46.4 0.6 47.3 43.1 12/30/2005 18:00:00 12 1.1 14.9 9.5 11.9 1.1 14.9 9.5 21 6 27 305 46.3 1.3 47.7 37.6 12/30/2005 18:10:00 12.3 1.1 15.6 9.5 12.3 1.2 15.6 8.8 20 5 30 305 45.4 1 47.3 37.9 12/30/2005 18:20:00 12 1.2 14.9 8.8 11.9 1.2 14.9 8.8 22 5 20 305 45.8 0.8 47.3 42.4 12/30/2005 18:30:00 11 1.1 14.1 8.8 10.9 1.1 14.1 8.8 23 5 19 305 44.4 1.6 46.6 40.6 12/30/2005 18:40:00 11.8 1.2 14.5 9.1 11.6 1.2 14.5 8.4 21 5 17 305 43.9 1.6 45.9 34.6 12/30/2005 18:50:00 11.2 1.2 14.1 8.4 11 1.2 14.1 8.4 22 6 21 305 44 1.8 46.3 34.6 12/30/2005 19:00:00 10.7 1.1 14.1 8.4 10.5 1.2 13.7 8 23 5 21 305 43.2 1.9 44.8 32 12/30/2005 19:10:00 11 1.1 13.3 7.6 10.9 1.1 13.3 8 19 5 14 305 43 1 45.2 34.9 12/30/2005 19:20:00 11.2 1.1 13.7 8.8 11 1.2 13.7 8.4 20 5 17 305 42.9 1.5 44.5 34.9 12/30/2005 19:30:00 11.1 1 13.7 8.8 11 1 14.1 8.4 21 5 27 305 40.2 4 43.4 23.4 12/30/2005 19:40:00 12.1 1.3 14.9 9.5 12 1.3 15.3 9.1 15 6 19 305 40.7 2.1 43.4 32 12/30/2005 19:50:00 11.7 1.2 14.1 8.4 11.5 1.2 14.1 8.8 17 5 21 305 41.8 1.4 43.4 33 12/30/2005 20:00:00 11.6 1.1 14.1 8.8 11.6 1.2 14.1 8.4 16 5 17 305 41.2 1.3 43.1 32.6 12/30/2005 20:10:00 12.5 1.3 15.3 9.5 12.4 1.3 15.6 9.1 19 5 23 305 40.8 0.8 42.7 35.3 12/30/2005 20:20:00 12.5 1.3 15.6 9.1 12.2 1.2 15.3 8.8 24 5 26 305 39.8 0.7 41 37.6 12/30/2005 20:30:00 13 1.4 16.4 9.5 12.6 1.4 16.1 9.1 26 5 26 305 39.2 0.8 40.6 37.9 12/30/2005 20:40:00 12.4 1.2 15.3 9.5 12.2 1.3 15.3 9.5 25 5 25 305 38.8 0.7 40.6 37.6 12/30/2005 20:50:00 11.8 1 14.5 9.1 11.5 1.1 14.1 8.8 23 6 18 305 40.4 1.1 42 37.9 12/30/2005 21:00:00 12.4 1.8 17.6 8.8 12.1 1.7 18.3 8.8 25 6 38 305 41.8 0.7 43.1 39.6 12/30/2005 21:10:00 15.6 2.2 20.2 11.5 15.2 2.1 20.2 11.1 33 7 37 305 42.5 0.3 43.4 42 12/30/2005 21:20:00 15.8 1.5 19.5 11.8 15.5 1.5 19.9 11.1 34 6 33 305 43.1 0.2 44.1 42.4 12/30/2005 21:30:00 15.7 2.2 21 9.9 15.3 2.1 20.2 9.5 35 6 35 305 42.9 1.1 44.5 33.3 12/30/2005 21:40:00 16.2 2.6 22.6 10.7 15.9 2.5 21.4 9.9 33 8 31 305 42.7 0.3 43.4 40.6 12/30/2005 21:50:00 13.5 1.5 17.6 9.9 13.3 1.5 17.6 9.9 25 5 23 305 42.5 0.2 43.4 40.3 12/30/2005 22:00:00 15.1 2.4 21 10.3 14.7 2.3 21 10.3 35 7 35 305 42.9 0.5 43.8 35.9 12/30/2005 22:10:00 15.6 2 20.2 11.5 15.2 1.9 19.9 11.1 33 7 51 305 42.9 0.2 43.8 41 12/30/2005 22:20:00 12.5 1.3 15.6 9.1 12.3 1.2 16.1 9.1 19 6 8 305 43 0.4 44.1 41.7 12/30/2005 22:30:00 12.3 1.5 16.1 9.1 12.2 1.5 16.4 8.4 21 5 16 305 43.4 0 44.5 42.7 12/30/2005 22:40:00 12.6 1.2 15.3 9.1 12.5 1.3 14.9 8.8 25 5 25 305 43.9 0.1 44.5 43.4 12/30/2005 22:50:00 12.9 1.2 15.6 9.9 12.7 1.2 16.1 9.5 25 5 27 305 44.2 0.1 45.2 43.8 12/30/2005 23:00:00 12.7 1.4 16.4 9.5 12.4 1.5 16.1 9.1 26 6 27 305 44.3 0.1 45.2 43.8 12/30/2005 23:10:00 11.7 1.3 14.9 8.8 11.4 1.3 14.9 8.8 25 6 22 305 42.9 1 45.2 41.3 12/30/2005 23:20:00 12.3 1.3 15.6 8.4 12.1 1.4 15.3 8.4 26 5 30 305 42.1 0.4 43.1 38.9 12/30/2005 23:30:00 12.9 1.1 16.1 10.7 12.7 1.1 15.6 9.9 26 5 27 305 42 0.4 42.7 38.6 12/30/2005 23:40:00 12.4 1.3 15.6 8.8 12.2 1.2 14.9 9.5 27 6 23 305 41.8 0.9 43.1 38.6 12/30/2005 23:50:00 13.5 1.3 17.2 10.7 13.4 1.4 17.2 9.9 19 5 19 305 42 0.1 42.7 41.7 12/31/2005 00:00:00 13.1 1.3 16.4 9.1 13 1.4 16.4 9.1 19 5 15 305 42.1 0.5 43.1 38.6 12/31/2005 00:10:00 14.6 1.2 17.6 11.1 14.4 1.2 17.6 11.1 19 5 19 305 42.2 0 43.1 41.7 12/31/2005 00:20:00 14.1 1.7 17.6 9.9 13.9 1.6 17.9 10.7 20 5 25 305 42.2 1.1 43.4 38.3 12/31/2005 00:30:00 13.7 1.5 17.2 10.3 13.4 1.5 17.2 9.9 20 5 14 305 41.8 1.4 43.1 38.6 12/31/2005 00:40:00 13.1 1.2 16.4 9.9 12.9 1.2 16.1 9.9 20 6 24 305 41.9 1.5 43.1 38.6 12/31/2005 00:50:00 12.7 1.3 16.1 9.1 12.6 1.3 15.6 9.1 23 5 27 305 42 1.5 43.4 38.3 12/31/2005 01:00:00 14.6 2.4 21.4 9.5 14.5 2.4 21 9.5 22 6 14 305 39.4 0.7 43.1 38.6 12/31/2005 01:10:00 16.4 1.7 21 11.8 15.9 1.7 21 11.5 31 6 31 305 40.9 1.7 43.8 38.6 12/31/2005 01:20:00 16 1.7 20.6 12.2 15.6 1.7 20.2 11.5 33 5 31 305 39.4 0.5 40.6 37.9 12/31/2005 01:30:00 13.8 1.4 16.8 9.5 13.7 1.5 16.8 9.5 18 5 25 305 39.1 1.5 42.7 36.6 12/31/2005 01:40:00 12.9 1.1 16.1 10.3 12.7 1.2 16.1 9.9 21 5 16 305 40.9 1.8 43.1 37.2 12/31/2005 01:50:00 13.3 1.1 16.8 9.9 13.1 1.1 16.4 10.3 19 5 21 305 41 1.6 42.7 35.9 12/31/2005 02:00:00 13.6 1.5 17.2 9.1 13.3 1.4 16.8 8.8 22 7 12 305 41.2 1.5 43.1 37.2 12/31/2005 02:10:00 16.2 2.5 22.9 11.1 15.8 2.4 22.6 11.8 33 6 32 305 39.3 1.8 42.7 34.9 12/31/2005 02:20:00 16.9 1.6 20.6 12.2 16.4 1.7 20.2 12.2 33 5 27 305 38.3 0.9 39.6 34.3 12/31/2005 02:30:00 13.6 1.3 18.3 9.9 13.4 1.2 17.9 10.3 23 8 39 305 38.4 0.5 39.6 37.2 12/31/2005 02:40:00 14.4 2.2 21.4 9.9 14.1 2 19.9 10.7 23 7 22 305 38.4 1 42.4 37.2 12/31/2005 02:50:00 17.6 2.1 22.6 12.6 17.1 2.1 21.8 12.2 31 6 30 305 39.7 1.5 43.4 37.6 12/31/2005 03:00:00 17.2 1.7 21.8 13.3 16.8 1.7 21.8 12.6 33 6 37 305 40.8 2.4 45.5 37.6 12/31/2005 03:10:00 16.8 2.4 23.7 12.2 16.5 2.4 22.9 11.8 32 6 35 305 40.6 2.2 43.8 35.6 12/31/2005 03:20:00 18.6 2.2 23.7 12.6 18.2 2.3 24.4 13 33 7 32 305 41.4 1.5 43.1 36.2 12/31/2005 03:30:00 17.5 2.4 22.6 11.8 17 2.2 22.9 11.8 32 5 35 305 41.4 1.2 44.5 36.6 12/31/2005 03:40:00 18.7 2 24 14.5 18.3 2.1 24 13.7 36 6 37 305 41.8 1 44.1 36.6 12/31/2005 03:50:00 18.3 1.7 22.6 14.5 17.9 1.7 22.6 13 33 6 36 305 41.5 1 43.8 38.3 12/31/2005 04:00:00 17.2 1.7 21.4 13.3 16.8 1.7 21.4 12.2 33 6 39 305 41.4 2 43.8 35.9 12/31/2005 04:10:00 16.5 2 21.8 12.2 16.1 1.9 21 11.5 34 6 33 305 38.5 1 39.6 29.5 12/31/2005 04:20:00 17.4 1.8 22.1 13 16.9 1.9 21.8 12.2 34 6 40 305 38.8 0.2 39.6 37.9 12/31/2005 04:30:00 17.1 2.3 22.1 12.2 16.7 2.2 22.6 12.2 33 6 29 305 38.8 0.8 40 35.6 12/31/2005 04:40:00 16.6 1.8 22.1 12.6 16.3 1.8 22.6 12.6 32 6 26 305 38.8 0.9 39.6 34.6 12/31/2005 04:50:00 17.3 2.1 21.8 12.2 16.9 2.1 21.8 11.8 32 6 33 305 39.4 2.4 46.6 35.6 12/31/2005 05:00:00 18.1 2 22.9 13 17.6 2 22.9 13 32 5 27 305 45.2 1.7 47.7 38.3 12/31/2005 05:10:00 16.8 1.9 21.4 12.2 16.5 1.9 21.8 11.8 31 6 34 305 42.8 2.3 47.3 33.3 12/31/2005 05:20:00 17.7 1.7 21.4 13.7 17.2 1.7 21.8 12.6 30 5 35 305 40 1.3 43.8 36.6 12/31/2005 05:30:00 18.6 1.7 22.9 13 18.3 1.7 22.9 13.3 32 6 35 305 41.4 1.4 44.8 34.6 12/31/2005 05:40:00 17.7 1.7 21 13 17.2 1.7 21.4 13 32 6 26 305 42.5 0.9 45.2 34.9 12/31/2005 05:50:00 15.7 1.5 20.2 11.8 15.5 1.5 19.9 11.8 32 5 27 305 42.7 0.8 44.5 33.6 12/31/2005 06:00:00 16.4 1.5 20.2 13 16 1.5 19.5 12.2 32 6 32 305 43.9 1.5 47 36.9 12/31/2005 06:10:00 16.4 1.7 21 12.6 15.9 1.7 21 11.5 30 6 36 305 44.9 1.6 47.3 37.9 12/31/2005 06:20:00 17 1.8 21 12.6 16.7 1.9 21 11.8 31 6 33 305 45.6 0.7 47 43.1 12/31/2005 06:30:00 15.5 2.1 20.6 11.1 15.1 2 20.6 10.7 29 6 34 305 45.2 1.7 47.7 37.9 12/31/2005 06:40:00 16 1.8 21 11.8 15.9 1.7 20.6 11.5 33 6 33 305 46 1.4 48.4 38.6 12/31/2005 06:50:00 16.3 2 20.6 10.7 15.9 1.9 20.2 11.5 30 6 29 305 47.8 0.8 49.5 45.5 12/31/2005 07:00:00 16.5 1.9 20.6 11.8 16.1 1.8 20.6 11.8 34 5 37 305 46.6 0.2 47.3 45.2 12/31/2005 07:10:00 15.6 2.1 21.4 11.1 15.4 2.1 21 11.1 30 7 35 305 46 1.4 47.3 38.9 12/31/2005 07:20:00 18.4 2 22.6 12.2 17.8 2.1 23.7 13 29 6 33 305 43.1 2.9 48.1 38.6 12/31/2005 07:30:00 17.8 1.7 22.6 13.7 17.6 1.6 21.8 13.3 32 5 35 305 40.4 0.5 42.4 39.6 12/31/2005 07:40:00 15.9 2 21 11.1 15.4 2 20.2 11.1 31 5 37 305 40.4 0.3 41.7 39.6 12/31/2005 07:50:00 16.9 1.8 21.8 12.2 16.5 1.8 21.4 12.2 31 6 26 305 47 1.7 48.8 34.3 12/31/2005 08:00:00 16.8 2.1 22.6 12.2 16.6 1.9 22.1 12.2 27 8 27 305 47.3 0.6 48.4 37.9 12/31/2005 08:10:00 14.2 1.8 19.9 9.5 14.1 1.8 19.9 9.9 21 7 25 305 46.6 0.6 47.7 40.6 12/31/2005 08:20:00 16.4 2 22.1 12.2 16.1 2 21.8 11.8 28 6 29 305 46.3 1.2 47.7 36.9 12/31/2005 08:30:00 16.5 2.4 21.4 11.5 16.2 2.3 22.1 10.7 26 6 30 305 45.7 1.4 47 36.9 12/31/2005 08:40:00 15 1.5 19.1 11.5 14.7 1.6 18.3 10.3 19 5 22 305 45.3 1.2 47 40 12/31/2005 08:50:00 13.3 1.1 16.4 10.7 13.2 1.1 16.1 10.3 21 5 18 305 47.3 1.4 50.6 41 12/31/2005 09:00:00 14.8 2.4 21 9.5 14.7 2.3 20.6 9.5 29 6 16 305 49.3 0.4 50.6 48.1 12/31/2005 09:10:00 14.9 2 20.2 9.9 14.6 1.8 18.7 10.3 29 7 26 305 48.4 1.1 49.9 38.6 12/31/2005 09:20:00 13 1.6 16.4 8.8 12.7 1.6 17.2 8.8 21 7 35 305 48.6 1 50.3 41.3 12/31/2005 09:30:00 16.1 2.5 21 9.5 15.7 2.4 21 9.5 28 6 23 305 48.9 0.6 51 42 12/31/2005 09:40:00 16.4 2 20.6 11.1 16 2 20.6 10.3 27 6 24 305 49.6 1.8 51.8 38.6 12/31/2005 09:50:00 16.6 1.8 21 12.2 16.2 1.9 21 11.8 29 6 26 305 50 0.8 51.4 38.9 12/31/2005 10:00:00 15.9 2 20.6 10.7 15.4 2 20.6 11.1 27 6 21 305 49.5 1.2 50.6 30.7 12/31/2005 10:10:00 15.4 2.5 21.4 9.5 15.2 2.4 20.6 9.9 24 8 24 305 49 1.8 51.4 39.3 12/31/2005 10:20:00 15.2 2.5 22.1 10.3 15 2.4 21.4 9.5 24 6 30 305 49.2 1.2 50.6 38.9 12/31/2005 10:30:00 17.4 1.8 22.6 13.3 17 1.9 22.1 11.8 28 6 19 305 49 1 49.9 35.9 12/31/2005 10:40:00 17.6 2.1 22.6 11.8 17.1 2.1 22.1 11.5 30 6 31 305 49 0.4 49.9 45.5 12/31/2005 10:50:00 15.3 2.3 21 9.5 15 2.2 21.4 10.3 26 8 25 305 48.7 0.5 49.9 44.5 12/31/2005 11:00:00 15.4 2.4 22.9 10.7 15.2 2.4 22.1 10.3 24 7 22 305 49.3 0.9 51.4 41.7 12/31/2005 11:10:00 14.3 1.4 19.5 10.3 14.2 1.4 19.5 10.3 19 6 23 305 48.5 2.2 51 38.6 12/31/2005 11:20:00 14.1 1.3 17.6 11.1 13.9 1.2 17.2 11.1 19 6 19 305 50.6 1.4 52.9 40.6 12/31/2005 11:30:00 14 1.5 17.9 9.5 13.7 1.5 16.8 9.5 22 6 25 305 49.3 1.7 52.9 44.1 12/31/2005 11:40:00 14.8 1.7 19.5 11.1 14.5 1.7 19.1 10.7 23 6 27 305 49.2 1.5 52.9 44.1 12/31/2005 11:50:00 14.6 1.7 19.5 11.5 14.3 1.7 19.9 11.1 21 6 18 305 50.3 1.6 52.9 43.1 12/31/2005 12:00:00 14.6 2 19.9 9.9 14.5 1.9 19.5 10.3 21 6 18 305 49.7 1.6 52.5 40.3 12/31/2005 12:10:00 17.4 2 22.1 11.8 17 1.9 21.8 12.6 22 6 22 305 49 2.1 52.9 39.6 12/31/2005 12:20:00 16.4 2.5 22.1 10.3 16.1 2.6 22.1 10.3 24 6 21 305 48.9 1.3 51 42.7 12/31/2005 12:30:00 17.8 2.4 23.3 11.5 17.2 2.3 22.9 11.1 23 6 17 305 48.2 1.5 52.1 43.1 12/31/2005 12:40:00 17.7 2.1 23.3 11.8 17.3 2.1 22.9 12.2 24 6 20 305 47.5 1.2 49.9 42.7 12/31/2005 12:50:00 18.4 1.8 23.7 14.1 18.1 1.8 23.3 13.3 25 6 16 305 49.1 1.4 51.8 43.1 12/31/2005 13:00:00 17.5 2.1 22.6 11.8 17.2 2 22.1 11.8 23 5 19 305 49 1.5 51.8 40.3 12/31/2005 13:10:00 17.3 1.8 22.1 13 16.9 1.7 21.8 12.6 25 7 22 305 48.4 1.1 51.8 43.4 12/31/2005 13:20:00 17.6 2 23.7 13 17.2 2 22.9 12.2 25 6 21 305 47.8 1.4 50.6 42 12/31/2005 13:30:00 17.1 1.9 21.8 12.6 16.6 1.8 21.8 12.2 27 6 30 305 47.7 1.2 49.9 42 12/31/2005 13:40:00 16.5 1.9 21.4 12.2 16.1 1.7 21.4 12.2 27 6 21 305 46.5 1.8 49.9 38.6 12/31/2005 13:50:00 16.6 2.2 21.8 11.8 16.2 2.2 21.8 11.5 28 7 28 305 46.5 1.5 49.5 39.3 12/31/2005 14:00:00 14.7 2.1 20.2 9.5 14.4 1.9 19.1 9.5 29 5 22 305 46.6 1.1 48.8 40.3 12/31/2005 14:10:00 14.6 1.9 19.5 9.5 14.3 1.8 19.1 9.9 25 6 31 305 47.3 0.9 49.2 43.4 12/31/2005 14:20:00 15.8 2.5 21 10.7 15.4 2.3 20.6 10.7 26 7 24 305 46.6 1.2 48.8 38.6 12/31/2005 14:30:00 17.1 2.1 22.1 11.8 16.6 2.1 21.8 11.5 27 6 33 305 46.3 1.2 49.5 41.3 12/31/2005 14:40:00 17.7 2.2 22.6 12.6 17.2 2.2 22.1 12.2 25 6 27 305 47.1 1 49.5 42 12/31/2005 14:50:00 17.5 2.3 22.1 11.8 17 2 21.8 12.2 26 6 25 305 47.3 1.4 49.9 37.2 12/31/2005 15:00:00 17 1.8 22.1 12.2 16.8 1.7 21.4 12.6 26 6 27 305 47.3 1.2 49.5 40.3 12/31/2005 15:10:00 16.1 2.1 21.4 10.7 15.8 2 20.6 11.1 26 6 29 305 47.3 1.1 49.5 43.8 12/31/2005 15:20:00 14.9 2.3 21 9.9 14.5 2.3 20.6 9.9 26 6 18 305 46.5 1 49.9 44.5 12/31/2005 15:30:00 15.6 1.7 20.2 11.1 15.2 1.8 20.2 10.7 26 7 35 305 46.7 1 49.5 44.5 12/31/2005 15:40:00 15.4 2.1 20.2 10.7 15.1 2.2 21 10.3 27 6 25 305 47 0.9 49.5 44.5 12/31/2005 15:50:00 15.7 2.1 20.2 10.3 15.3 2.2 20.2 9.9 27 6 18 305 46.3 1 48.8 40.6 12/31/2005 16:00:00 15.6 1.5 19.1 11.8 15.2 1.5 19.5 11.8 28 6 27 305 46.3 1 48.8 40.3 12/31/2005 16:10:00 14.8 1.8 19.9 10.3 14.5 1.7 19.1 10.3 29 7 23 305 46.8 0.8 48.8 45.2 12/31/2005 16:20:00 15.9 2 20.6 11.1 15.6 1.9 20.6 10.3 28 6 35 305 46.9 0.8 48.8 45.5 12/31/2005 16:30:00 15.3 2 19.5 9.9 14.9 1.9 18.7 9.5 28 6 34 305 47.4 0.8 49.9 45.9 12/31/2005 16:40:00 14.6 1.8 19.1 10.3 14.2 1.7 19.5 9.9 28 6 28 305 47.8 1 49.9 45.9 12/31/2005 16:50:00 15.5 1.6 19.5 11.8 15.1 1.6 18.7 11.5 27 5 33 305 47.8 0.9 49.9 44.5 12/31/2005 17:00:00 16 1.7 20.2 11.8 15.6 1.7 21.4 11.1 28 6 45 305 47.6 0.9 49.9 45.9 12/31/2005 17:10:00 16.9 1.8 21 11.8 16.5 1.9 20.6 11.5 29 6 38 305 48.7 1.4 51 45.9 12/31/2005 17:20:00 15.7 2.1 21.4 11.1 15.3 2 20.6 10.7 29 6 30 305 48.9 1.5 51.4 45.9 12/31/2005 17:30:00 13.5 1.7 17.9 9.5 13.3 1.7 17.9 9.1 32 6 31 305 48.7 1.3 51.4 43.8 12/31/2005 17:40:00 15.1 1.9 19.9 9.5 14.8 1.8 19.9 10.3 29 7 21 305 48.4 2.1 51.8 41.7 12/31/2005 17:50:00 15.8 1.9 22.1 11.8 15.6 1.9 21 11.5 32 6 32 305 49.3 1.1 51.8 46.3 12/31/2005 18:00:00 17.3 1.8 21.4 12.2 16.8 1.7 20.6 11.8 32 5 29 305 48.8 0.8 49.9 44.5 12/31/2005 18:10:00 16.6 2.3 21.4 11.1 16.2 2.3 21.4 11.5 28 6 27 305 48.2 1.6 51.4 45.5 12/31/2005 18:20:00 15.3 1.9 19.9 10.7 14.9 1.8 19.9 11.1 29 6 21 305 48.2 1.2 50.3 44.1 12/31/2005 18:30:00 16.4 1.7 20.6 11.8 16 1.7 19.9 11.5 32 6 30 305 48.6 0.9 51 45.5 12/31/2005 18:40:00 16.7 1.9 21 12.2 16.5 1.8 21 11.5 34 6 32 305 49.3 1.2 51.8 43.4 12/31/2005 18:50:00 16.9 2.1 21.4 11.8 16.5 1.9 20.6 11.5 34 5 35 305 49 1.1 51.4 44.8 12/31/2005 19:00:00 16.7 2 21 11.8 16.4 2 21 11.8 35 6 37 305 48 0.6 49.9 47 12/31/2005 19:10:00 16.2 1.7 19.9 12.2 15.8 1.7 20.2 11.5 35 6 35 305 50 1.1 51.4 45.9 12/31/2005 19:20:00 15.2 1.7 18.7 11.1 14.9 1.7 18.7 10.7 35 5 36 305 51 0 51.4 50.6 12/31/2005 19:30:00 15.4 1.6 20.2 11.8 15.1 1.6 19.9 11.5 35 5 30 305 50.9 0 51.4 50.6 12/31/2005 19:40:00 16.2 1.7 19.9 12.2 15.9 1.7 19.5 11.8 33 5 35 305 50 1.4 51 40.6 12/31/2005 19:50:00 16.4 1.8 21.8 12.2 16.1 1.8 21 12.2 35 5 39 305 49 0.3 49.9 47.3 12/31/2005 20:00:00 15.9 1.5 20.2 12.2 15.5 1.6 19.9 11.8 36 6 35 305 49.2 1 49.9 40 12/31/2005 20:10:00 15.1 1.7 18.7 10.3 14.8 1.7 19.1 10.3 35 6 41 305 49.2 0 49.9 48.8 12/31/2005 20:20:00 15.2 1.9 22.1 11.5 14.7 1.9 20.2 10.7 32 5 30 305 48.3 0.1 48.8 47.7 12/31/2005 20:30:00 15.4 1.5 19.9 11.1 15.1 1.6 19.1 10.7 32 6 32 305 48.1 0.3 48.8 47.3 12/31/2005 20:40:00 16.4 1.9 20.2 11.8 16 2 19.9 11.5 31 5 33 305 47.4 0.2 47.7 45.2 12/31/2005 20:50:00 15.4 1.8 19.5 11.1 15.2 1.8 19.5 10.7 32 6 28 305 47.3 0 47.7 46.6 12/31/2005 21:00:00 15.9 1.7 19.9 11.1 15.6 1.6 19.1 11.8 34 6 35 305 46.9 0.3 47.7 44.8 12/31/2005 21:10:00 14.3 1.5 18.7 9.9 14.1 1.6 18.7 9.9 33 6 37 305 46.8 0 47 46.6 12/31/2005 21:20:00 15.9 1.5 19.5 11.5 15.5 1.5 19.5 11.8 32 6 31 305 46.6 0 47 46.3 12/31/2005 21:30:00 15.9 1.6 20.2 12.2 15.7 1.7 20.6 12.6 33 6 31 305 46.7 0 47 46.6 12/31/2005 21:40:00 16.5 2 20.2 11.1 16.1 2 20.6 11.5 31 5 43 305 46.3 0.1 46.6 45.5 12/31/2005 21:50:00 15.1 1.5 18.7 12.2 14.9 1.6 18.3 11.5 35 6 44 305 46.3 0.1 46.6 45.5 12/31/2005 22:00:00 14.8 1.5 17.9 10.7 14.6 1.5 17.9 10.7 36 5 39 305 45.7 0.5 46.6 44.8 12/31/2005 22:10:00 14.9 1.5 18.3 11.5 14.7 1.5 17.9 11.1 36 5 33 305 45.4 0 45.9 44.8 12/31/2005 22:20:00 14.1 1.5 19.1 10.3 13.9 1.6 18.7 10.3 35 5 28 305 45.1 1.4 45.5 22.8 12/31/2005 22:30:00 14.4 1.3 17.6 11.1 14.1 1.5 17.9 10.3 33 6 40 305 44.4 0.8 46.3 42 12/31/2005 22:40:00 15 1.6 18.7 9.9 14.7 1.7 18.7 10.3 33 5 38 305 43.8 1.2 44.8 30.7 12/31/2005 22:50:00 14.1 1.6 18.7 10.3 13.8 1.6 18.3 9.9 30 6 23 305 44.8 0.8 47.3 37.9 12/31/2005 23:00:00 14.3 1.5 17.6 10.7 14.2 1.4 17.6 10.7 30 6 27 305 45.4 0.7 47.3 37.9 12/31/2005 23:10:00 14.4 1.4 18.3 11.1 14.1 1.4 18.3 10.3 31 6 24 305 45 1.2 46.6 40.6 12/31/2005 23:20:00 14.8 1.4 17.9 11.5 14.5 1.4 17.6 11.1 33 6 29 305 45.1 0.3 45.5 43.1 12/31/2005 23:30:00 14.2 1.6 18.3 10.7 13.9 1.6 18.7 9.9 33 5 38 305 45.6 0.6 47.7 39.3 12/31/2005 23:40:00 13.2 1.1 16.1 9.9 13 1.2 16.1 9.9 21 7 18 305 45.9 1.1 48.4 40 12/31/2005 23:50:00 12.3 1.3 16.1 8.8 12.1 1.3 16.4 8.4 15 5 10 305 46.3 0.8 48.4 39.3 01/01/2006 00:00:00 13.6 1.3 16.1 9.5 13.6 1.3 16.4 9.9 13 5 17 305 46.2 0.8 48.4 44.1 01/01/2006 00:10:00 13 1.4 16.1 8.8 12.8 1.4 16.1 9.1 16 5 12 305 46.5 0.5 47.3 39.6 01/01/2006 00:20:00 11.9 1.3 14.5 8.4 11.8 1.3 15.3 8.4 20 6 8 305 46.3 1.1 47.3 33.9 01/01/2006 00:30:00 14 1.7 18.7 9.9 13.7 1.5 17.9 8.8 27 6 27 305 46.2 0.6 47 38.3 01/01/2006 00:40:00 15.9 1.7 19.9 11.8 15.7 1.7 19.5 11.1 26 6 18 305 45.4 2.4 47.3 36.6 01/01/2006 00:50:00 14.6 1.6 18.7 11.1 14.4 1.5 17.9 10.7 27 6 31 305 46 1.2 47.3 38.9 01/01/2006 01:00:00 15 1.6 19.5 9.9 14.7 1.7 19.1 10.7 27 5 27 305 45.9 0.4 46.6 42 01/01/2006 01:10:00 15.5 1.7 19.9 11.1 15.1 1.7 20.2 11.1 21 8 21 305 45.7 0.8 47.3 37.9 01/01/2006 01:20:00 13.8 1.4 17.6 10.3 13.7 1.4 17.9 10.7 11 5 8 305 45.9 0.6 46.6 39.6 01/01/2006 01:30:00 13.8 1.6 17.2 9.9 13.6 1.6 17.2 9.1 11 5 15 305 46.1 1.2 47.3 38.9 01/01/2006 01:40:00 14.3 1.4 17.9 11.1 14.1 1.4 18.3 10.7 11 5 9 305 46.4 1.9 48.4 36.2 01/01/2006 01:50:00 14.8 1.5 17.9 10.7 14.6 1.5 17.6 10.3 12 5 7 305 46.6 2 48.8 39.6 01/01/2006 02:00:00 14.3 1.4 17.6 10.3 14.2 1.5 17.2 9.5 12 5 12 305 46.4 1.7 48.8 37.9 01/01/2006 02:10:00 13.9 1.5 17.2 9.9 13.7 1.5 16.4 9.9 14 5 7 305 46.5 0.9 47.3 39.3 01/01/2006 02:20:00 13.6 1.4 17.2 10.3 13.5 1.4 17.2 9.5 14 5 14 305 47.1 2 49.5 38.6 01/01/2006 02:30:00 13.4 1.5 16.8 10.3 13.3 1.5 16.8 9.9 14 5 20 305 47.3 0.7 48.4 39.3 01/01/2006 02:40:00 12.8 1.2 15.6 9.9 12.8 1.2 15.6 9.9 13 5 16 305 46.5 2.2 48.4 38.9 01/01/2006 02:50:00 13.4 1.9 18.7 9.1 13.2 1.8 17.9 8.8 21 7 26 305 46.6 1.3 47.7 38.6 01/01/2006 03:00:00 15.2 1.6 19.5 11.5 14.9 1.5 18.7 11.1 25 6 19 305 45.3 2.1 47.3 37.9 01/01/2006 03:10:00 15.2 1.9 19.1 11.1 14.9 1.8 18.7 10.7 25 5 22 305 45.1 0.8 46.3 38.9 01/01/2006 03:20:00 14.3 1.7 19.5 10.3 14 1.7 19.5 10.3 16 9 25 305 44.1 1 45.2 37.6 01/01/2006 03:30:00 13.3 1.2 15.6 10.3 13.3 1.3 16.1 9.9 12 5 8 305 43.8 1.9 46.6 37.6 01/01/2006 03:40:00 13.7 1.5 17.2 10.7 13.6 1.5 17.2 10.3 10 5 15 305 43.7 2.6 46.6 37.6 01/01/2006 03:50:00 14.8 1.3 17.9 11.5 14.7 1.5 17.9 10.3 12 4 14 305 45.1 1.6 47.7 37.9 01/01/2006 04:00:00 14.1 1.3 17.9 11.1 13.9 1.3 18.7 10.7 14 5 13 305 45.3 1.1 47 37.6 01/01/2006 04:10:00 15.1 1.4 18.7 11.5 14.9 1.5 19.1 11.5 17 5 18 305 44.9 1.9 47.3 37.2 01/01/2006 04:20:00 14.3 1.6 17.9 10.3 14.2 1.6 18.3 9.9 18 5 23 305 45.1 2.2 47.3 37.2 01/01/2006 04:30:00 14.1 1.4 17.2 10.3 14.1 1.4 17.2 10.3 16 5 11 305 44.8 2.6 48.4 37.6 01/01/2006 04:40:00 12.5 1 15.3 9.9 12.5 1 14.9 9.1 15 5 23 305 45.7 2.3 48.4 37.6 01/01/2006 04:50:00 13.5 1.3 16.4 9.1 13.4 1.3 16.4 9.9 14 5 11 305 46 1.5 47.7 38.3 01/01/2006 05:00:00 12.1 1.5 16.4 8.8 12 1.5 16.4 8.8 15 5 16 305 45.8 1.9 47.3 37.6 01/01/2006 05:10:00 12.6 1.5 16.1 8.8 12.6 1.6 16.1 8.4 15 6 18 305 45.4 2 47.7 35.9 01/01/2006 05:20:00 13.7 1.7 17.6 9.5 13.5 1.7 17.2 9.1 14 6 12 305 46.1 2 47.7 37.9 01/01/2006 05:30:00 14.3 1.3 17.9 11.1 14.2 1.4 17.9 10.3 14 5 19 305 46.3 2.1 47.7 37.2 01/01/2006 05:40:00 12.5 1.6 16.8 9.1 12.5 1.5 17.2 8.8 15 5 19 305 46.2 2.5 48.8 37.9 01/01/2006 05:50:00 14 1.4 17.2 9.9 14 1.5 17.2 9.5 16 5 16 305 46.1 2.5 48.1 37.9 01/01/2006 06:00:00 13.1 1.5 16.4 9.5 13 1.5 16.4 9.5 16 5 17 305 45.8 1.8 47.3 38.9 01/01/2006 06:10:00 13 1.3 16.8 9.5 12.9 1.3 16.8 9.9 17 6 8 305 45.8 2 48.1 34.6 01/01/2006 06:20:00 12.6 1.4 17.2 9.9 12.4 1.5 17.6 8.8 16 5 17 305 46 2.3 48.8 32.6 01/01/2006 06:30:00 13.1 1.3 16.4 9.1 13 1.3 16.1 9.5 14 6 29 305 46.9 1.6 48.8 35.3 01/01/2006 06:40:00 13.5 1.5 17.6 10.3 13.3 1.5 17.2 9.9 11 5 12 305 47.6 2.3 48.8 40 01/01/2006 06:50:00 13.3 1.3 16.4 10.3 13 1.3 16.4 9.9 14 6 16 305 47.2 1.7 48.8 39.6 01/01/2006 07:00:00 12.9 1.3 16.4 9.9 12.8 1.3 16.1 9.9 13 5 18 305 47.3 0 47.7 47 01/01/2006 07:10:00 12.5 1.2 15.6 9.5 12.4 1.3 15.6 9.1 16 6 29 305 45.7 1.8 48.4 39.3 01/01/2006 07:20:00 13.1 1.4 17.2 10.3 13 1.4 17.2 9.9 17 7 16 305 44.8 2.8 48.4 34.9 01/01/2006 07:30:00 12.6 1.1 14.9 9.9 12.5 1.1 15.6 9.5 13 6 19 305 43.7 2 46.6 35.9 01/01/2006 07:40:00 13 1.2 16.1 9.5 12.7 1.2 16.1 9.9 11 5 9 305 43.3 1.8 45.2 34.3 01/01/2006 07:50:00 13 1.2 15.6 9.5 12.9 1.2 15.6 8.4 13 5 13 305 44.1 2.4 45.5 37.2 01/01/2006 08:00:00 12 1.5 15.6 8.8 12 1.5 15.6 8.8 16 5 16 305 43.2 2.5 48.4 29.5 01/01/2006 08:10:00 12.1 1.3 15.3 8.8 12 1.4 15.3 8.8 16 5 17 305 41 1.8 47.7 37.9 01/01/2006 08:20:00 12 1.2 15.3 8.8 11.8 1.2 15.3 8.8 17 5 10 305 39.6 1.2 42 33.3 01/01/2006 08:30:00 13.1 1.3 16.4 8.8 13.1 1.3 16.4 9.5 16 5 16 305 43.9 2.7 48.4 37.9 01/01/2006 08:40:00 11.6 1.3 14.5 8.4 11.5 1.2 14.1 8 15 6 21 305 44.9 1.8 47.3 39.6 01/01/2006 08:50:00 12.5 1.3 16.4 9.5 12.3 1.5 16.1 9.5 16 6 8 305 38.8 1.6 42 34.9 01/01/2006 09:00:00 12.9 1.3 16.1 9.1 12.8 1.2 16.1 9.5 15 5 20 305 38.5 0.9 39.6 36.2 01/01/2006 09:10:00 13.3 1.3 16.4 9.9 13.2 1.3 16.8 10.3 15 5 16 305 40.6 1.2 43.1 37.2 01/01/2006 09:20:00 12.5 1.3 15.6 9.1 12.4 1.3 16.4 9.1 15 5 18 305 42.3 1 43.8 39.3 01/01/2006 09:30:00 12 1.5 15.6 8.4 12.1 1.5 15.6 9.1 14 6 23 305 43.2 1.9 47.7 36.9 01/01/2006 09:40:00 12.2 1.3 15.3 9.1 12.1 1.2 14.9 8.8 16 5 18 305 44 2.9 47.3 36.6 01/01/2006 09:50:00 12 1.2 14.9 8.8 11.9 1.2 14.9 9.1 14 5 12 305 41.9 2.3 43.8 16.7 01/01/2006 10:00:00 11.9 1.1 14.5 8.8 11.8 1.1 14.1 8.4 16 5 19 305 42.5 2.1 44.1 17.6 01/01/2006 10:10:00 12.3 1.2 15.3 9.5 12.2 1.2 15.3 9.5 13 5 12 305 42.4 1 43.4 31.4 01/01/2006 10:20:00 12.7 1.2 15.6 9.5 12.6 1.2 15.6 8.8 16 5 15 305 42.5 1.8 44.8 31.7 01/01/2006 10:30:00 12 1.5 16.1 8.4 11.9 1.4 15.6 8.8 16 6 11 305 42.4 1.1 44.5 32.3 01/01/2006 10:40:00 13.6 1.3 17.2 9.9 13.6 1.3 17.2 10.7 15 5 15 305 46.5 2.6 48.8 31.7 01/01/2006 10:50:00 12.5 1.5 15.6 8.8 12.4 1.4 16.1 8.8 14 5 7 305 43.8 1.5 45.9 32.6 01/01/2006 11:00:00 12.8 1.4 16.4 9.9 12.5 1.4 15.6 8.8 14 5 10 305 43.9 0.7 45.9 34.9 01/01/2006 11:10:00 13.3 1.4 16.4 9.9 13.1 1.5 16.1 9.5 16 5 18 305 44.4 1.3 46.3 33.3 01/01/2006 11:20:00 12.8 1.5 16.1 8.4 12.7 1.5 15.6 7.6 15 5 19 305 43.2 1.7 48.4 31.7 01/01/2006 11:30:00 13.1 1.6 17.6 9.5 12.9 1.6 17.2 9.1 17 5 13 305 46.3 1.8 48.4 40.3 01/01/2006 11:40:00 12.7 1.5 16.1 9.5 12.7 1.5 16.4 8.8 17 5 26 305 42.3 1.5 48.4 40.3 01/01/2006 11:50:00 12.6 1.4 16.4 8.8 12.3 1.6 16.8 8.8 15 5 11 305 43.2 1.4 46.3 31.4 01/01/2006 12:00:00 12.4 1.2 14.9 9.5 12.3 1.2 14.9 9.5 15 5 13 305 44.1 1.2 46.3 35.9 01/01/2006 12:10:00 11.8 1.5 14.9 8.4 11.7 1.4 15.6 8.4 14 5 19 305 44.3 1.7 47.7 33 01/01/2006 12:20:00 11.5 1.2 15.3 8.8 11.4 1.2 15.6 8.8 13 6 8 305 45.5 1.9 48.8 38.6 01/01/2006 12:30:00 12.5 1.3 16.1 9.1 12.5 1.2 16.1 9.1 14 5 8 305 42.9 1.9 45.9 32.6 01/01/2006 12:40:00 13.2 1.4 17.2 9.5 13 1.4 16.4 9.9 13 6 5 305 43.2 1.2 44.5 34.9 01/01/2006 12:50:00 13.4 1.3 16.4 9.9 13.3 1.3 16.4 9.9 13 5 10 305 41.8 2.2 44.5 33.6 01/01/2006 13:00:00 12.7 1.4 16.1 9.5 12.7 1.5 16.4 9.1 14 5 10 305 42.1 2.2 45.5 34.6 01/01/2006 13:10:00 12.8 1.2 15.3 9.1 12.8 1.2 15.3 8.8 14 5 13 305 43.4 1.9 46.3 35.3 01/01/2006 13:20:00 12 1.5 15.6 8.8 11.9 1.5 15.3 8.4 14 5 21 305 41.7 1.9 44.8 33.3 01/01/2006 13:30:00 12.1 1.2 15.3 9.1 12.2 1.2 14.9 9.1 15 5 21 305 43 1.9 45.5 34.6 01/01/2006 13:40:00 12.4 1.2 15.6 8.8 12.4 1.2 15.6 9.1 13 5 17 305 45.8 2.1 48.4 37.9 01/01/2006 13:50:00 12 1.2 15.3 9.1 12 1.3 15.3 8.8 11 5 8 305 46.3 1.2 48.8 40.6 01/01/2006 14:00:00 13.1 1.5 17.2 9.9 12.9 1.4 16.8 9.5 11 5 4 305 46.3 1.7 48.4 39.3 01/01/2006 14:10:00 13.7 1.5 16.8 9.9 13.6 1.6 17.2 9.9 13 5 11 305 44.7 1.5 47 36.6 01/01/2006 14:20:00 12.7 1.4 16.8 8.4 12.7 1.5 16.1 8.8 15 6 10 305 45.5 1.6 47.7 37.2 01/01/2006 14:30:00 13.2 1.5 16.4 10.3 13.1 1.5 17.6 10.3 14 6 13 305 44.7 1.3 47.3 37.6 01/01/2006 14:40:00 12.7 1.3 15.6 9.5 12.6 1.3 15.6 9.9 15 5 16 305 43.4 2 46.3 31.7 01/01/2006 14:50:00 12.2 1.3 15.3 8.8 11.9 1.4 15.6 8.8 13 6 8 305 39.3 2.3 43.1 29.2 01/01/2006 15:00:00 13.1 1.3 17.2 9.9 13 1.3 16.8 9.5 13 5 13 305 36.6 2.7 41.3 28.5 01/01/2006 15:10:00 12.4 1.5 15.6 8 12.4 1.4 16.1 8 12 6 9 305 35.9 2.5 41 28.5 01/01/2006 15:20:00 12.7 1.3 15.3 8.8 12.6 1.3 15.3 9.1 11 5 18 305 37.5 2.7 40.6 27.6 01/01/2006 15:30:00 12.5 1.5 16.1 8 12.4 1.5 15.6 8.4 11 5 14 305 38.5 1.2 40 31 01/01/2006 15:40:00 11.3 1.2 15.3 8.8 11.3 1.2 15.6 8.8 13 5 9 305 37.4 1.9 40.3 29.8 01/01/2006 15:50:00 10.1 0.9 12.6 7.2 10.1 1 13 7.6 13 5 11 305 36.2 1.1 38.6 30.1 01/01/2006 16:00:00 10.8 1.7 15.6 7.6 10.5 1.8 15.6 7.2 24 9 26 305 36.2 1.8 38.6 29.5 01/01/2006 16:10:00 13.9 1.4 17.6 9.9 13.6 1.5 17.6 9.5 29 5 26 305 35.8 1.5 37.9 26.1 01/01/2006 16:20:00 14.2 1.3 17.6 10.7 13.9 1.4 17.6 10.3 28 6 27 305 35.9 1.8 38.3 29.2 01/01/2006 16:30:00 13.4 1.5 17.2 9.9 13.2 1.6 17.2 9.9 28 6 31 305 36.3 1.5 38.3 23.4 01/01/2006 16:40:00 12.5 1.3 16.8 9.5 12.2 1.2 16.1 9.1 30 6 29 305 33.5 2 37.2 28.2 01/01/2006 16:50:00 12.8 1.4 17.2 9.9 12.5 1.4 16.8 9.5 34 6 31 305 31.1 2.3 33.6 18.4 01/01/2006 17:00:00 13.6 1.7 18.3 10.3 13.3 1.7 18.3 8.8 35 6 34 305 31.9 1.3 33.6 27.3 01/01/2006 17:10:00 15.2 1.5 19.1 10.3 15 1.5 18.7 11.1 32 6 37 305 31.6 1 33.9 27.6 01/01/2006 17:20:00 15.6 1.7 20.2 11.1 15.2 1.7 19.5 11.1 31 6 31 305 29.4 1.9 32.6 22.2 01/01/2006 17:30:00 14.2 1.8 19.1 9.9 13.8 1.7 18.7 9.9 31 6 27 305 27.8 1.8 30.4 21.9 01/01/2006 17:40:00 12.5 1.8 17.9 8.8 12.4 1.7 17.6 8.4 18 8 28 305 25.6 1.9 28.8 20.4 01/01/2006 17:50:00 11.4 1 14.1 9.1 11.4 1.1 14.1 8.4 11 6 10 305 23.5 1.5 25.8 20.4 01/01/2006 18:00:00 12.3 1.2 15.6 9.1 12.3 1.2 15.3 8.8 11 5 15 305 23.6 1.4 26.4 17.6 01/01/2006 18:10:00 12 1.3 15.6 8.8 11.9 1.4 15.3 8.4 14 6 18 305 21.9 1.4 24.9 17 01/01/2006 18:20:00 11.4 1.4 15.3 8.4 11.3 1.4 14.9 8.8 14 5 17 305 21.1 2.2 23.1 -7.1 01/01/2006 18:30:00 11.5 1.2 14.5 8 11.4 1.3 14.1 7.2 12 6 14 305 21.9 1.1 24 17.9 01/01/2006 18:40:00 10.5 1.1 13 7.6 10.5 1.1 13.3 7.6 16 6 10 305 22.5 1.6 24.6 17.9 01/01/2006 18:50:00 10.4 1 13.7 7.6 10.2 1 13.3 7.2 22 7 18 305 20.6 1.8 24.3 14.3 01/01/2006 19:00:00 14.1 1.9 18.7 10.3 13.9 1.9 18.7 9.9 34 6 32 305 20 0.9 21.9 16.2 01/01/2006 19:10:00 14 2 18.3 9.1 13.9 1.9 18.3 8.8 34 7 42 305 19.9 1.2 21.9 15.1 01/01/2006 19:20:00 15 1.4 18.7 11.5 14.6 1.5 18.3 11.5 35 6 35 305 20.3 2.2 24.6 15.6 01/01/2006 19:30:00 14.8 1.7 19.5 11.1 14.5 1.7 18.3 10.3 34 6 44 305 23.4 1.3 24.9 18.7 01/01/2006 19:40:00 15.4 1.7 19.5 11.8 15.1 1.7 20.2 11.1 35 6 37 305 22.8 1.5 24.9 16.7 01/01/2006 19:50:00 15.9 1.8 21 11.8 15.6 1.7 21 11.8 35 6 22 305 22.7 1.5 24.9 19 01/01/2006 20:00:00 16 1.7 21.8 12.2 15.4 1.7 19.5 10.7 32 6 40 305 22.8 1.7 25.2 19.3 01/01/2006 20:10:00 15.4 2 19.9 11.1 15 2 19.5 11.1 32 6 31 305 22.6 1.6 24.9 18.7 01/01/2006 20:20:00 16.1 1.7 20.2 11.5 15.7 1.7 19.9 11.1 31 6 36 305 21.8 1.7 24.3 16.7 01/01/2006 20:30:00 15.2 1.5 19.1 11.5 14.7 1.5 19.1 11.5 31 6 29 305 20.6 1.6 23.1 17.6 01/01/2006 20:40:00 14.6 1.5 18.3 11.1 14.2 1.5 18.3 10.7 29 6 29 305 19.6 0.9 22.5 17 01/01/2006 20:50:00 14.6 1.7 19.5 11.1 14.3 1.7 17.9 10.3 30 6 28 305 20.7 0.7 21.6 18.7 01/01/2006 21:00:00 15 1.7 19.1 10.7 14.7 1.7 18.7 10.3 29 6 31 305 20.2 0.6 21.6 18.1 01/01/2006 21:10:00 15.6 1.3 18.3 11.8 15.2 1.4 18.7 11.8 30 6 26 305 20.6 1 24.6 19 01/01/2006 21:20:00 14.9 1.6 19.1 11.8 14.7 1.5 18.7 11.5 29 5 31 305 22.8 1.5 24.6 18.7 01/01/2006 21:30:00 16 1.7 20.2 11.5 15.6 1.6 20.2 11.8 29 6 24 305 21.4 1.5 24.9 19.6 01/01/2006 21:40:00 14.3 2.4 19.5 8.4 13.9 2.2 19.1 8.8 32 7 25 305 22.1 1.8 24.9 19 01/01/2006 21:50:00 15.4 1.9 19.5 11.5 15.1 1.9 19.5 10.7 32 6 29 305 22.3 1.5 24.6 19.3 01/01/2006 22:00:00 16.2 1.6 19.9 11.5 15.9 1.7 20.2 11.5 32 6 31 305 22.2 1.5 25.5 19 01/01/2006 22:10:00 15.8 2.1 20.6 11.1 15.4 2 21 9.9 29 6 29 305 25.2 2.3 28.8 20.4 01/01/2006 22:20:00 15.2 1.7 19.1 10.7 14.9 1.7 19.1 10.7 32 6 33 305 26.2 2.1 29.8 21.9 01/01/2006 22:30:00 16 1.7 20.6 12.2 15.7 1.8 20.2 11.1 32 6 33 305 25.8 2.4 30.1 21.6 01/01/2006 22:40:00 16.2 1.8 21.4 11.1 15.8 1.7 20.2 11.1 30 6 34 305 27.1 2.3 30.1 22.8 01/01/2006 22:50:00 15.6 1.7 19.5 12.2 15.2 1.7 19.9 11.1 29 6 32 305 26.7 1.9 28.8 21.9 01/01/2006 23:00:00 14.1 1.7 18.3 10.3 13.8 1.6 17.6 9.9 31 6 29 305 25.8 2 28.8 20.4 01/01/2006 23:10:00 14.9 1.9 19.5 10.7 14.7 1.9 19.5 9.9 32 6 30 305 25.6 2.2 28.8 22.2 01/01/2006 23:20:00 14.2 1.2 17.6 11.1 13.9 1.3 17.2 10.7 35 5 41 305 26.1 2 28.5 22.8 01/01/2006 23:30:00 14 1.4 17.6 10.7 13.6 1.5 16.8 10.7 30 6 35 305 26.1 1.3 28.2 21.9 01/01/2006 23:40:00 13.2 1.6 17.6 8.8 12.9 1.5 17.6 9.5 35 6 35 305 25.8 2.1 27.6 2.9 01/01/2006 23:50:00 13.5 1.1 16.4 11.1 13.3 1.2 16.4 10.3 35 5 38 305 26.1 1.4 27.6 20.7 01/02/2006 00:00:00 13.4 1.5 18.3 9.5 13.2 1.5 18.3 9.5 30 7 23 305 24.9 2.1 27.6 21.6 01/02/2006 00:10:00 13.7 1.6 20.2 9.9 13.5 1.6 19.1 10.3 27 7 33 305 24.7 2.1 27.3 19.6 01/02/2006 00:20:00 14.1 1.8 19.9 9.9 13.9 1.7 19.5 10.7 27 6 32 305 25.2 2 27.6 21.3 01/02/2006 00:30:00 13.9 1.3 17.6 11.1 13.7 1.4 17.6 11.1 28 6 30 305 24.5 2.2 27 18.1 01/02/2006 00:40:00 14.3 1.7 19.5 10.3 14 1.8 19.1 10.3 29 6 26 305 24.2 2.3 27.6 19.6 01/02/2006 00:50:00 14.3 1.7 18.7 10.7 14.2 1.7 18.7 10.3 31 6 36 305 23.5 2.5 26.7 19 01/02/2006 01:00:00 13.3 1.5 17.2 9.9 13.1 1.5 16.8 9.1 32 5 36 305 23.1 1.9 25.5 18.4 01/02/2006 01:10:00 13.5 1.5 17.9 9.9 13.1 1.5 17.6 9.5 32 6 30 305 22 2 24.6 17.6 01/02/2006 01:20:00 13.9 1.5 17.9 10.3 13.5 1.5 17.6 9.9 31 6 36 305 21.4 2 24.3 17.3 01/02/2006 01:30:00 13.2 1.5 17.2 8.8 13 1.4 17.2 9.5 32 6 30 305 21.2 1.8 24.6 18.7 01/02/2006 01:40:00 13.4 1.4 17.9 10.3 13.1 1.5 17.6 10.3 33 5 27 305 21.2 2 24.9 18.4 01/02/2006 01:50:00 12.8 1.5 17.9 9.5 12.5 1.6 16.4 9.1 33 6 28 305 21.4 1.5 24 17.9 01/02/2006 02:00:00 11.9 1.1 14.1 9.1 11.6 1.1 14.9 9.1 35 7 32 305 21.3 1.8 23.4 17.9 01/02/2006 02:10:00 12.4 1.3 15.3 9.1 12 1.3 15.6 9.1 34 6 39 305 19.5 1.8 23.7 17.6 01/02/2006 02:20:00 12.6 1.3 16.8 9.1 12.3 1.4 16.8 9.5 35 6 30 305 18.3 1 21 10 01/02/2006 02:30:00 12.8 1.2 15.6 9.5 12.7 1.2 16.1 9.9 35 6 31 305 18.7 1.2 21 15.6 01/02/2006 02:40:00 12.8 1.2 16.4 9.1 12.4 1.2 15.6 9.1 37 5 46 305 17.8 2 21.9 10 01/02/2006 02:50:00 12.5 1.3 15.6 9.9 12.3 1.3 15.6 8.4 36 6 35 305 17 2.2 19.6 12.4 01/02/2006 03:00:00 12.9 1.3 16.1 8.8 12.7 1.4 16.1 8.8 36 5 38 305 15.6 1.8 21 12.1 01/02/2006 03:10:00 13.1 1.3 16.1 9.1 12.7 1.3 16.1 9.9 36 6 32 305 13.6 0.8 15.6 11.6 01/02/2006 03:20:00 13 1.3 16.4 9.9 12.6 1.3 15.6 9.9 37 5 26 305 14.5 0.5 16.2 12.9 01/02/2006 03:30:00 13.2 1.2 17.2 10.3 12.9 1.3 16.8 9.5 36 6 36 305 15.6 0.8 17.3 12.4 01/02/2006 03:40:00 13.9 1.3 17.9 11.1 13.7 1.3 17.6 10.3 35 6 32 305 15.8 0.4 17 13.7 01/02/2006 03:50:00 12.8 1.2 15.6 9.5 12.6 1.3 16.4 9.5 36 6 36 305 15.2 0.4 16.7 12.9 01/02/2006 04:00:00 12.7 1.2 15.3 9.9 12.4 1.3 16.4 9.1 36 5 32 305 15.8 0.4 17.3 13.7 01/02/2006 04:10:00 13.3 1.4 17.2 8.8 13 1.4 17.6 9.1 34 5 45 305 16 0.6 17.9 12.1 01/02/2006 04:20:00 13.9 1.3 17.9 10.7 13.5 1.4 16.8 10.3 34 6 34 305 13.3 0.9 15.9 11 01/02/2006 04:30:00 14.1 1.2 16.8 10.7 13.9 1.2 17.2 9.9 35 5 28 305 13.2 0.6 14.8 11.3 01/02/2006 04:40:00 13.2 1.3 16.8 10.3 13 1.5 16.4 9.5 34 6 28 305 12.4 2.8 19.3 7.9 01/02/2006 04:50:00 14.2 1.2 17.9 11.5 13.9 1.2 17.2 11.1 34 5 27 305 16.9 2.1 19.6 11.6 01/02/2006 05:00:00 13.5 1.2 16.4 10.7 13.4 1.2 16.1 10.3 34 5 35 305 18.8 2.2 21.6 10 01/02/2006 05:10:00 13 1.5 16.8 9.9 12.7 1.5 16.1 9.1 34 6 32 305 19.1 1.9 21.9 9.7 01/02/2006 05:20:00 12.8 1.4 15.6 9.5 12.6 1.4 16.4 9.5 33 5 27 305 18 2.5 22.8 8.9 01/02/2006 05:30:00 12.6 1.5 16.1 9.5 12.2 1.5 16.1 9.5 33 6 29 305 18.4 2.3 21.6 10 01/02/2006 05:40:00 12.9 1.3 17.6 10.3 12.7 1.4 17.6 9.5 31 6 26 305 18.7 2.2 21.6 10.5 01/02/2006 05:50:00 13.9 1.3 17.6 10.3 13.5 1.3 17.2 9.5 31 6 33 305 18.9 2.4 22.5 11.3 01/02/2006 06:00:00 14.3 1.4 17.6 10.7 14.1 1.4 16.8 10.3 32 5 31 305 18.7 2.4 21.9 10 01/02/2006 06:10:00 13 1.5 16.4 9.5 12.8 1.5 16.4 9.5 35 6 36 305 17.4 2.5 20.7 8.9 01/02/2006 06:20:00 13.5 1.5 17.6 9.9 13.2 1.5 16.8 9.1 34 7 22 305 17.4 2.9 21 2.7 01/02/2006 06:30:00 13.4 1.2 16.4 10.3 13.1 1.3 16.8 9.9 36 5 29 305 19.5 2.2 21.9 11 01/02/2006 06:40:00 14 1.3 16.8 10.7 13.7 1.5 16.8 9.9 36 6 39 305 20.2 2.1 22.5 12.1 01/02/2006 06:50:00 13.9 1.3 17.9 10.7 13.7 1.3 17.6 10.3 35 5 33 305 20.6 2.4 23.4 12.1 01/02/2006 07:00:00 14.3 1.4 17.9 11.1 14.1 1.5 17.9 10.7 36 6 32 305 21.2 2.4 24 12.6 01/02/2006 07:10:00 14.2 1.4 19.1 11.1 14 1.5 17.9 11.1 36 5 28 305 21.8 1.7 24.3 16.7 01/02/2006 07:20:00 14.5 1.2 17.9 11.8 14.2 1.3 17.9 11.5 33 6 27 305 17.6 2.7 22.5 10.5 01/02/2006 07:30:00 14.4 1.6 18.3 9.9 14.1 1.6 17.9 9.9 33 5 34 305 17 2.3 20.1 9.7 01/02/2006 07:40:00 13.9 1.4 16.8 10.3 13.6 1.4 17.6 9.9 33 6 28 305 17 2.5 20.4 4.2 01/02/2006 07:50:00 13 1.2 15.6 9.5 12.8 1.3 16.1 9.5 35 7 33 305 18.4 2.1 21.9 11.3 01/02/2006 08:00:00 13.2 1.3 17.2 10.7 12.9 1.3 16.4 10.3 34 6 31 305 17.6 2 20.4 8.7 01/02/2006 08:10:00 13.6 1.3 19.1 10.3 13.3 1.3 17.9 9.9 34 6 27 305 16.1 1.8 19 10 01/02/2006 08:20:00 13.3 1.3 16.8 10.3 13 1.3 16.4 9.9 36 6 33 305 13 0.8 15.6 8.7 01/02/2006 08:30:00 13.8 1.2 17.2 10.7 13.3 1.3 17.6 10.3 37 5 39 305 13 1.4 17 9.2 01/02/2006 08:40:00 12.9 1.1 16.1 9.9 12.7 1.2 16.1 9.5 36 5 32 305 16.8 1.4 19.3 9.2 01/02/2006 08:50:00 13.1 1.3 16.8 9.9 12.7 1.4 17.2 9.9 36 6 30 305 14.4 2.5 18.7 -3.3 01/02/2006 09:00:00 13 1.4 16.8 8.8 12.8 1.4 17.6 9.1 35 5 38 305 14.3 2.3 19.6 5.6 01/02/2006 09:10:00 12.6 1.5 16.4 9.5 12.4 1.5 16.1 9.5 33 6 31 305 14.6 2 19.6 9.7 01/02/2006 09:20:00 13.2 1.3 17.6 10.3 12.7 1.3 16.8 9.9 33 6 34 305 14.6 1 17.3 10.2 01/02/2006 09:30:00 13.3 1.4 16.8 9.9 13 1.3 16.4 9.1 33 6 29 305 14.2 1 17 8.4 01/02/2006 09:40:00 12.8 1.4 17.2 9.5 12.5 1.3 16.4 9.9 32 6 29 305 13.8 1.5 16.7 -2.7 01/02/2006 09:50:00 13.5 1.3 16.4 10.3 13.4 1.2 16.4 10.3 34 5 32 305 13.2 1.2 15.3 3.4 01/02/2006 10:00:00 13.9 1.3 17.6 10.7 13.7 1.4 17.2 10.7 33 6 25 305 14.1 1.4 16.2 -2.9 01/02/2006 10:10:00 13.8 1.5 17.2 10.3 13.5 1.5 16.8 10.3 34 6 29 305 16.1 1.8 19.9 11.3 01/02/2006 10:20:00 13.4 1.5 16.8 9.9 13.2 1.5 17.2 9.5 35 5 33 305 15.4 1.4 18.1 1 01/02/2006 10:30:00 13.5 1.5 17.6 9.9 13.3 1.5 17.9 9.5 34 5 33 305 14.7 1.2 17.3 2.9 01/02/2006 10:40:00 13.2 1.4 16.8 9.9 12.8 1.4 16.4 9.9 33 6 39 305 15.7 2.2 17.9 4.4 01/02/2006 10:50:00 12.8 1.2 16.1 9.5 12.5 1.3 15.6 9.1 28 8 33 305 16.2 1.7 18.4 4.4 01/02/2006 11:00:00 11.1 1.1 14.1 7.6 11 1.2 14.1 7.6 13 6 22 305 16.9 1.2 17.9 8.9 01/02/2006 11:10:00 12.8 1.3 16.1 8.8 12.8 1.4 15.6 8.8 12 5 12 305 16.8 2.3 19 7.7 01/02/2006 11:20:00 11.7 1.3 16.1 8.4 11.5 1.4 16.4 8.4 15 5 9 305 17.2 1.4 18.1 6.9 01/02/2006 11:30:00 12.7 1.3 16.1 9.5 12.7 1.3 16.1 8.8 15 6 14 305 18.1 2.1 21.3 10.8 01/02/2006 11:40:00 12.6 1.5 15.6 8.8 12.5 1.5 16.1 8.4 15 5 15 305 19.3 2.2 21 12.4 01/02/2006 11:50:00 12.6 1.2 15.6 9.1 12.5 1.2 15.3 9.5 16 5 17 305 19.1 1.8 21 12.9 01/02/2006 12:00:00 11.8 1.3 14.9 8.8 11.7 1.3 14.5 8.8 15 5 18 305 20.3 1.8 21.9 14.3 01/02/2006 12:10:00 12.3 1.3 14.9 9.1 12.2 1.3 15.6 8.8 13 6 7 305 20.4 2.7 25.5 14 01/02/2006 12:20:00 12.4 1.2 15.3 9.1 12.3 1.3 16.1 9.5 12 5 6 305 23.2 1.2 26.4 21 01/02/2006 12:30:00 12.5 1.5 15.6 9.5 12.4 1.5 15.6 8.8 13 5 18 305 24 1.3 26.7 22.8 01/02/2006 12:40:00 12.5 1.5 16.1 8.8 12.4 1.5 16.1 8 13 6 17 305 23.7 1.4 27.3 21.3 01/02/2006 12:50:00 13.9 1.2 16.8 10.7 13.8 1.3 17.2 10.7 12 5 17 305 23.9 1.5 27 21.6 01/02/2006 13:00:00 13.2 1.3 16.4 9.5 13 1.3 16.8 9.5 14 6 18 305 24.3 1.3 27 21.9 01/02/2006 13:10:00 12.8 1.5 16.4 9.1 12.8 1.4 16.1 9.5 13 5 15 305 24.1 1.3 27 21.6 01/02/2006 13:20:00 11.9 1.5 15.6 8 11.8 1.5 15.6 8.4 12 5 11 305 23.7 1.5 26.4 20.4 01/02/2006 13:30:00 13.3 1.2 16.4 9.9 13.1 1.2 16.1 9.9 12 6 19 305 22.1 1.4 25.2 19.6 01/02/2006 13:40:00 12.2 1.4 16.1 9.1 12.1 1.3 15.6 9.1 10 6 5 305 21.2 1.5 24.6 16.2 01/02/2006 13:50:00 12.2 1.5 16.4 9.1 12.1 1.5 16.4 8.8 13 6 20 305 21.9 1.5 25.2 19.3 01/02/2006 14:00:00 12.1 1.4 15.6 8.4 12.1 1.4 15.6 8.4 12 6 14 305 22 1.5 24.9 19.3 01/02/2006 14:10:00 12.4 1.3 15.6 8.8 12.3 1.2 15.6 9.5 13 5 13 305 22.8 1.6 27 18.7 01/02/2006 14:20:00 12.5 1.5 16.1 8.8 12.4 1.5 16.1 8.8 12 6 16 305 23.8 1.8 27.3 18.1 01/02/2006 14:30:00 12.4 1.3 16.4 9.1 12.2 1.4 15.6 8.8 12 5 15 305 22.8 1.7 26.4 20.1 01/02/2006 14:40:00 12.8 1.3 16.1 9.1 12.5 1.3 16.4 9.5 10 6 10 305 21.4 1.6 24.9 18.4 01/02/2006 14:50:00 12.4 1.3 15.6 8.4 12.4 1.3 15.3 8.8 12 5 18 305 22 1.8 24.9 17.9 01/02/2006 15:00:00 11.3 1.6 16.1 7.6 11.3 1.5 16.1 8.4 10 6 8 305 22.4 1.5 26.4 19.3 01/02/2006 15:10:00 11.9 1.4 14.9 8.8 11.8 1.5 15.3 8.4 10 6 7 305 23.4 1.8 26.4 20.1 01/02/2006 15:20:00 11.9 1.5 16.1 7.2 11.8 1.6 15.6 8 10 6 12 305 22.9 1.6 26.7 19.6 01/02/2006 15:30:00 11.9 1.2 14.5 8.8 11.8 1.2 14.5 8.8 12 6 11 305 23.4 1.6 26.4 20.1 01/02/2006 15:40:00 12.1 1.2 14.9 9.1 12.1 1.1 14.9 9.5 13 5 11 305 22.8 1.5 26.1 19.6 01/02/2006 15:50:00 11.3 1.6 14.9 8 11.2 1.7 14.9 7.6 12 6 18 305 22.7 1.5 25.8 17.9 01/02/2006 16:00:00 12.4 1.2 15.3 9.5 12.3 1.3 16.4 8.8 9 6 9 305 22.3 1.2 25.5 18.7 01/02/2006 16:10:00 12.2 1.5 15.3 9.1 12.2 1.4 15.6 9.1 9 5 4 305 21.8 1 24.6 19 01/02/2006 16:20:00 12.5 1.3 15.6 9.1 12.6 1.3 15.6 8.8 8 5 5 305 22.1 0.8 24.9 19.6 01/02/2006 16:30:00 12.7 1.5 16.1 8.4 12.6 1.5 15.3 8.4 8 6 16 305 22.4 1.3 25.2 19.6 01/02/2006 16:40:00 11.4 1.3 15.3 7.2 11.4 1.4 15.6 7.2 10 5 16 305 22 1.4 25.8 17.6 01/02/2006 16:50:00 12.9 1.3 15.6 9.1 12.7 1.3 15.6 8.8 9 5 10 305 19.8 2.6 24.3 15.6 01/02/2006 17:00:00 12.8 1.4 16.4 9.1 12.7 1.5 16.1 8.8 11 5 19 305 19.5 1.5 22.8 16.5 01/02/2006 17:10:00 13.3 1.4 16.1 9.9 13.1 1.5 16.1 8.8 11 5 12 305 17.7 1.4 21.3 13.7 01/02/2006 17:20:00 13.6 1.7 17.2 9.1 13.4 1.7 17.6 8.4 11 5 8 305 18.6 1.1 21.9 16.2 01/02/2006 17:30:00 13.1 1.2 15.6 9.5 13 1.2 15.6 9.9 12 5 17 305 19.6 1.6 23.4 12.4 01/02/2006 17:40:00 13.3 1.5 16.8 9.5 13.2 1.5 16.8 9.5 9 5 8 305 21 1.4 24.3 18.1 01/02/2006 17:50:00 14.1 1.2 17.2 10.7 14 1.3 17.6 11.1 9 5 11 305 21.6 1.3 24 18.7 01/02/2006 18:00:00 14.1 1.7 17.2 8.8 13.9 1.7 17.2 8.8 8 5 5 305 21.4 1.6 23.4 18.7 01/02/2006 18:10:00 12.9 1.4 15.6 9.5 12.8 1.3 16.1 9.1 6 6 7 305 20.7 1.6 23.7 17 01/02/2006 18:20:00 13.5 1.1 16.1 11.1 13.4 1.2 16.1 9.1 8 5 12 305 20.9 1.5 23.7 16.7 01/02/2006 18:30:00 13.7 1.5 17.2 9.1 13.7 1.5 17.6 9.9 9 5 1 305 20.4 1.8 22.8 17.9 01/02/2006 18:40:00 14.3 1.6 17.9 8.8 14.2 1.7 17.9 9.9 10 5 14 305 21.2 1.5 23.7 17.6 01/02/2006 18:50:00 14.3 1.1 16.8 11.5 14.1 1.2 16.8 10.7 9 5 7 305 21 1.5 24 18.4 01/02/2006 19:00:00 13.5 1.3 16.4 9.9 13.2 1.4 16.8 9.9 9 5 9 305 18.8 0.8 20.7 17.9 01/02/2006 19:10:00 12.7 1.6 16.4 8 12.6 1.7 16.4 8.8 6 5 4 305 18.1 0.3 19 17.3 01/02/2006 19:20:00 11.7 1.5 16.1 8 11.6 1.5 16.1 8 8 6 15 305 19 1.5 21.3 14.3 01/02/2006 19:30:00 12.7 1.5 16.8 9.1 12.6 1.6 16.4 8.4 11 6 3 305 19.8 1.8 21.3 12.4 01/02/2006 19:40:00 13.4 1.3 16.8 9.9 13.3 1.4 16.8 9.5 11 5 14 305 19.3 0.9 20.7 15.6 01/02/2006 19:50:00 13.8 1 17.2 10.7 13.8 1.1 17.2 11.1 9 6 12 305 19.6 0.6 20.1 16.7 01/02/2006 20:00:00 13.9 1.2 16.4 10.7 13.8 1.2 16.4 10.7 11 5 11 305 19.3 1.5 21.3 12.4 01/02/2006 20:10:00 13.7 1.6 17.6 9.5 13.5 1.6 17.6 9.5 10 5 13 305 20.6 0.9 21.9 14.3 01/02/2006 20:20:00 12.9 1.5 16.4 9.5 12.8 1.5 16.8 8.8 10 6 8 305 20.6 1.2 22.2 13.4 01/02/2006 20:30:00 13.2 1.2 16.1 9.5 13.1 1.3 16.4 9.5 7 6 10 305 21.7 0.8 22.2 16.2 01/02/2006 20:40:00 13.5 1.9 16.8 8.8 13.4 1.8 17.6 9.1 7 5 4 305 21.8 0.7 22.5 18.7 01/02/2006 20:50:00 12.9 1.4 16.1 9.9 12.7 1.4 16.4 9.5 9 5 10 305 21.4 0.7 22.2 16.7 01/02/2006 21:00:00 12 1.5 16.1 8.8 12.1 1.7 16.8 8.4 10 6 9 305 20.8 0.9 22.5 18.7 01/02/2006 21:10:00 13.2 1.8 16.4 9.1 13.1 1.8 16.4 8.8 9 5 5 305 16.9 1.6 21.3 11 01/02/2006 21:20:00 13.2 1.5 16.4 9.9 13.1 1.6 17.2 9.5 10 5 7 305 14 1.2 15.9 9.7 01/02/2006 21:30:00 12.3 1.3 15.3 8.4 12.2 1.3 15.3 8.8 13 5 10 305 13.8 2.6 19.6 9.2 01/02/2006 21:40:00 13 1.2 15.6 9.1 13 1.2 15.6 9.5 7 5 358 305 19.1 0.5 20.1 17.6 01/02/2006 21:50:00 12.5 1.4 17.2 9.1 12.6 1.5 17.6 9.1 9 6 5 305 20.1 1 21.9 17.3 01/02/2006 22:00:00 14.3 1.3 17.9 11.1 14.3 1.3 17.2 11.1 8 5 1 305 19.3 0.7 20.4 15.1 01/02/2006 22:10:00 12.7 1.8 16.8 8.4 12.6 1.7 16.8 8.8 10 6 8 305 18.6 1.1 21 14.8 01/02/2006 22:20:00 13 1.5 16.8 8.8 12.9 1.6 17.2 9.1 8 7 3 305 16.5 2.8 21 9.5 01/02/2006 22:30:00 12.8 1.4 16.1 9.5 12.8 1.4 16.4 9.5 11 5 15 305 20.2 2.9 22.2 9.2 01/02/2006 22:40:00 11.9 1.6 15.6 7.6 11.9 1.6 15.3 8 9 6 1 305 21.7 0.7 22.2 19.6 01/02/2006 22:50:00 12.9 1.5 15.6 9.1 12.7 1.6 16.1 8.8 7 6 9 305 21.6 0.4 21.9 19.3 01/02/2006 23:00:00 12.1 1.7 15.3 8.8 12.1 1.7 15.6 8.4 9 6 7 305 20.3 1 21.9 18.1 01/02/2006 23:10:00 12.5 1.3 16.1 9.5 12.4 1.3 15.6 9.5 10 6 4 305 20 0.9 21 17 01/02/2006 23:20:00 12.5 1.4 15.3 8.4 12.5 1.5 15.6 8.8 12 5 11 305 20.1 1 21.3 17.6 01/02/2006 23:30:00 11.2 1.3 14.5 8.4 11.3 1.3 14.5 8.4 10 5 1 305 19.6 1.1 21 15.3 01/02/2006 23:40:00 12.3 1.2 15.3 9.1 12.4 1.1 15.6 9.1 11 5 13 305 19.1 0.9 20.1 15.1 01/02/2006 23:50:00 12.6 1.4 15.6 9.1 12.6 1.4 16.1 9.1 8 6 7 305 18.5 1.3 20.1 13.2 01/03/2006 00:00:00 12.1 1.5 16.4 8.4 12.2 1.5 16.4 8.8 11 5 10 305 19.6 0.6 20.4 17.6 01/03/2006 00:10:00 12.2 1.6 15.6 8 12.2 1.6 15.6 8.4 12 6 17 305 19.1 0.8 20.4 17 01/03/2006 00:20:00 12.6 1.3 15.6 9.1 12.5 1.3 15.6 9.5 11 6 3 305 19.5 0.6 20.4 17.6 01/03/2006 00:30:00 12.5 1.4 15.6 8.8 12.4 1.4 16.1 8.8 12 5 19 305 18.8 1 19.9 15.6 01/03/2006 00:40:00 12.3 1.2 15.3 9.1 12.1 1.3 15.6 9.1 13 5 17 305 19.2 0.8 20.1 14 01/03/2006 00:50:00 13 1.4 16.1 9.9 13 1.5 16.1 9.5 12 5 15 305 18.5 0.9 19.3 14.5 01/03/2006 01:00:00 12.6 1.3 14.9 9.1 12.5 1.2 14.9 9.5 11 5 9 305 18.6 0.7 19.3 16.2 01/03/2006 01:10:00 12.1 1.3 14.5 8.8 12.1 1.2 14.9 8.4 11 5 12 305 18.7 0.8 19.6 16.2 01/03/2006 01:20:00 11.8 1.4 14.5 7.6 11.8 1.3 15.3 9.1 13 5 18 305 18.8 1.1 19.9 16.2 01/03/2006 01:30:00 11.8 1.4 14.5 8 11.7 1.4 14.5 8 12 4 8 305 18 1.3 19.6 12.9 01/03/2006 01:40:00 11.5 1.3 15.3 8.4 11.4 1.4 15.6 8.4 14 6 12 305 15 2.3 19.3 5.9 01/03/2006 01:50:00 11.8 1.4 14.5 8.4 11.8 1.4 14.9 8.4 11 6 7 305 18.4 1.1 19.6 12.9 01/03/2006 02:00:00 12 1.1 14.9 9.1 11.9 1.1 14.5 9.1 12 5 7 305 19.6 0 20.1 17.3 01/03/2006 02:10:00 11.4 1.3 14.1 8.8 11.3 1.3 13.7 8.4 12 5 6 305 19.2 0.5 19.9 15.9 01/03/2006 02:20:00 11.4 1.2 13.7 7.6 11.3 1.2 14.1 8 14 5 11 305 18.4 1.4 20.4 15.3 01/03/2006 02:30:00 10.9 1 13.7 8.4 10.8 1 13.7 8.4 13 5 2 305 15.6 3.2 20.4 10.2 01/03/2006 02:40:00 11.1 1.5 14.1 7.2 11 1.4 14.1 7.6 12 5 14 305 20.1 0.8 20.7 15.3 01/03/2006 02:50:00 12.4 1.1 14.9 9.1 12.3 1.1 14.5 8 10 5 8 305 19.9 1.6 21.3 14.8 01/03/2006 03:00:00 11.9 1.2 14.9 8.4 11.7 1.2 14.5 8 12 5 14 305 20.4 0.6 21.3 16.5 01/03/2006 03:10:00 11.7 1.4 14.5 8.4 11.6 1.3 14.5 8 13 6 17 305 19.9 0.5 20.7 17.9 01/03/2006 03:20:00 13.3 1.4 16.1 9.5 13.2 1.4 16.1 9.9 14 5 15 305 19.8 0.8 20.4 15.6 01/03/2006 03:30:00 14.1 1 16.4 10.7 13.9 1.2 16.1 10.3 13 5 12 305 20.5 0.6 21.3 17.3 01/03/2006 03:40:00 13.4 1.1 15.6 9.5 13.3 1.2 16.1 9.5 11 5 13 305 20.7 1.2 21.9 13.4 01/03/2006 03:50:00 13 1.5 16.4 8.8 12.8 1.5 16.1 8.8 12 5 15 305 20.9 2 22.2 14.8 01/03/2006 04:00:00 12.9 1.1 15.3 9.9 12.7 1.2 15.6 9.5 12 5 9 305 21.7 0.7 22.2 16.5 01/03/2006 04:10:00 12.7 1.3 15.6 9.1 12.6 1.3 16.1 9.5 17 5 17 305 21.7 0.7 22.2 18.4 01/03/2006 04:20:00 12.8 1.6 16.1 8.4 12.6 1.5 16.1 8 16 4 14 305 21.2 1.6 22.5 15.3 01/03/2006 04:30:00 11.7 1.4 14.9 8 11.5 1.4 14.9 7.6 15 6 12 305 20.5 1.8 22.8 17 01/03/2006 04:40:00 12.2 1.8 16.4 8.4 12.2 1.8 16.4 8.4 16 6 20 305 22.5 0.5 23.4 19.3 01/03/2006 04:50:00 13.7 1 15.6 9.9 13.4 1.1 15.6 10.3 17 5 18 305 20.4 2.6 23.4 15.3 01/03/2006 05:00:00 12.5 1.4 15.3 8 12.4 1.5 15.6 8.8 19 5 16 305 23 0.1 23.7 21.9 01/03/2006 05:10:00 12.4 1.6 16.8 8 12.3 1.6 16.4 8.8 15 6 15 305 22.5 1.1 23.7 16.2 01/03/2006 05:20:00 12.2 1.5 15.3 7.2 12.2 1.5 15.6 8 13 5 14 305 23 0.2 23.7 21 01/03/2006 05:30:00 11.7 1.2 14.5 8.4 11.6 1.2 14.5 8.8 17 7 14 305 23.1 0.4 23.7 20.4 01/03/2006 05:40:00 12 1.6 16.4 8 11.8 1.6 15.6 8 17 6 22 305 23 0.5 23.7 20.1 01/03/2006 05:50:00 12.9 1.1 15.6 8.8 12.7 1.2 15.6 8.8 20 6 22 305 21.8 1.2 23.4 15.3 01/03/2006 06:00:00 12.6 1.1 15.3 9.5 12.6 1.2 15.3 9.9 17 6 19 305 22.1 1.1 23.4 16.2 01/03/2006 06:10:00 12.2 1.5 14.9 8.8 11.9 1.5 15.3 8 19 5 18 305 20.1 0.4 21.3 19 01/03/2006 06:20:00 11.9 1.3 14.5 8.8 12 1.3 14.9 8.8 18 5 21 305 22.3 1.6 24.3 17.3 01/03/2006 06:30:00 12.5 1.2 15.3 9.5 12.4 1.2 14.9 9.5 20 5 18 305 23.7 1 25.5 19 01/03/2006 06:40:00 11.6 1.3 15.3 8.8 11.4 1.3 14.5 8.8 19 5 14 305 24.6 0.9 25.5 21.6 01/03/2006 06:50:00 10 1 12.6 8 10 1.1 12.6 7.2 19 6 32 305 25 0.2 25.5 23.1 01/03/2006 07:00:00 11.4 1.3 14.5 8 11.3 1.3 14.1 8 17 5 13 305 25.2 0.4 26.1 23.1 01/03/2006 07:10:00 11 1.3 13.7 8 10.9 1.5 13.7 7.2 17 6 11 305 24.9 0.9 26.1 21.6 01/03/2006 07:20:00 10.8 1 13.7 7.2 10.7 1.1 13.7 8 19 5 18 305 23.5 2.6 26.1 14 01/03/2006 07:30:00 11.2 1 13.3 8 11.1 1 13 8.8 17 5 24 305 25.9 2.3 28.8 15.9 01/03/2006 07:40:00 10.3 1.1 13.3 7.6 10.4 1.1 13 7.6 14 6 13 305 25.7 2.1 28.8 16.2 01/03/2006 07:50:00 10.5 1.2 12.6 7.6 10.4 1.3 13 6.8 17 5 17 305 23.9 2.8 28.8 11.3 01/03/2006 08:00:00 10 1 12.6 7.2 9.9 1 12.2 6.8 16 5 11 305 25.5 2.6 28.5 14.8 01/03/2006 08:10:00 10.6 1.1 13 7.6 10.5 1.1 13.3 7.6 17 5 25 305 27.4 1.5 28.8 22.2 01/03/2006 08:20:00 10 1 11.8 7.6 9.8 1 12.2 7.2 15 6 20 305 26.6 1.8 28.8 21.6 01/03/2006 08:30:00 9.8 1.1 13 7.2 9.7 1.2 13 7.2 13 5 16 305 26 1.4 27.6 21 01/03/2006 08:40:00 9.9 1.1 13 6.8 9.9 1.1 13 7.2 13 5 10 305 25.7 1.7 28.2 20.7 01/03/2006 08:50:00 9.9 1.1 13 7.2 9.9 1.2 13 7.2 11 6 17 305 25.7 1.7 27.9 20.1 01/03/2006 09:00:00 10.4 1 12.6 8 10.4 1.1 13.3 7.6 11 5 13 305 25.4 1.2 27.6 20.4 01/03/2006 09:10:00 9.1 0.9 11.5 6.5 9 1.1 11.8 6.5 12 6 357 305 26.1 1.5 28.2 20.7 01/03/2006 09:20:00 10 1 13 7.6 9.9 1 13 7.2 15 5 18 305 25.3 1.8 27.6 19.9 01/03/2006 09:30:00 9.8 1 12.2 7.2 9.7 1.1 13 7.2 12 5 11 305 24.3 1.7 27.3 19.3 01/03/2006 09:40:00 9.1 1.3 11.8 6.5 9.2 1.3 12.6 6.5 6 5 3 305 23.4 1.5 25.8 17.9 01/03/2006 09:50:00 9.8 0.8 11.8 7.6 9.8 1 11.8 7.2 5 5 0 305 24.7 1.7 27.3 19.9 01/03/2006 10:00:00 9.7 1.2 12.2 6.8 9.7 1.3 12.6 6.8 10 6 10 305 24.6 1.4 25.8 20.4 01/03/2006 10:10:00 8.8 1.2 11.5 6.1 8.6 1.2 11.1 6.1 8 6 10 305 23.6 2.1 26.4 14 01/03/2006 10:20:00 8.8 0.9 11.1 6.5 8.6 1 11.1 6.5 9 6 12 305 18.6 3.2 23.4 11.3 01/03/2006 10:30:00 9.5 1.2 12.2 6.1 9.3 1.2 12.2 6.5 10 6 8 305 15.7 1.6 19.6 -0.6 01/03/2006 10:40:00 9.5 1 11.8 6.8 9.4 1 11.8 7.2 13 5 10 305 15.2 1.1 18.1 12.4 01/03/2006 10:50:00 10.1 1.1 12.2 7.2 10.1 1.1 12.2 7.2 12 4 14 305 14.6 1 16.5 10 01/03/2006 11:00:00 8.5 1 10.7 6.1 8.4 1 11.1 6.1 12 6 14 305 13.9 1.1 16.2 5.9 01/03/2006 11:10:00 9.2 0.9 11.5 6.5 9.1 0.9 11.5 6.5 15 5 21 305 18.1 3.8 23.7 2.7 01/03/2006 11:20:00 8.5 1 10.7 5.7 8.5 1 10.7 6.1 13 6 11 305 22.8 1.2 24.3 16.7 01/03/2006 11:30:00 8.5 1 11.1 6.1 8.5 1.1 11.5 6.1 12 6 4 305 22.5 1 24.9 14.5 01/03/2006 11:40:00 9.3 1 11.8 6.5 9.4 1.1 12.6 6.8 11 6 10 305 22 0.9 23.7 12.4 01/03/2006 11:50:00 8.6 1 11.1 6.1 8.6 1.1 11.8 6.5 12 6 8 305 20.9 1.9 23.4 15.1 01/03/2006 12:00:00 8.4 1 11.1 5.7 8.4 1 11.1 6.1 9 5 1 305 22 1 23.7 15.3 01/03/2006 12:10:00 8.3 1 10.7 6.1 8.2 1.1 10.7 6.1 8 5 8 305 21.7 1.8 24 11.8 01/03/2006 12:20:00 8.3 1 9.9 5.7 8.2 1.1 10.7 5.3 10 6 11 305 21.2 2.1 24 14 01/03/2006 12:30:00 8.8 0.8 10.7 6.5 8.8 0.9 10.7 6.5 10 5 11 305 21.7 1.2 23.4 14.5 01/03/2006 12:40:00 9 1 11.5 6.5 9 1 11.5 6.8 10 6 10 305 20.1 2.5 23.4 12.9 01/03/2006 12:50:00 9 0.9 11.1 6.5 8.8 1 11.5 6.5 12 5 13 305 17.3 0.7 19 15.3 01/03/2006 13:00:00 9.1 1 11.5 5.7 9 1.1 11.5 6.1 11 5 5 305 16.6 0.5 17.9 15.6 01/03/2006 13:10:00 8.5 1 11.5 5.7 8.4 1 11.5 6.1 12 6 5 305 16.7 0.5 17.6 15.6 01/03/2006 13:20:00 9.1 0.9 11.1 6.8 9.1 1 11.8 6.1 10 6 3 305 17.1 0.5 17.9 15.9 01/03/2006 13:30:00 8.5 1 10.3 5.7 8.4 1 10.7 5.7 13 5 10 305 20.1 1.9 22.2 16.2 01/03/2006 13:40:00 8.9 1 11.1 6.1 8.9 1.2 11.1 5.7 11 5 10 305 21.7 0.2 21.9 21 01/03/2006 13:50:00 8.4 1 10.3 6.1 8.3 1 10.7 6.1 12 6 10 305 21.4 0.1 21.9 21.3 01/03/2006 14:00:00 8.3 0.9 11.5 5.7 8.3 1 11.1 5.7 10 5 15 305 21.1 0.6 21.9 19.6 01/03/2006 14:10:00 9.6 0.9 11.5 6.5 9.6 0.9 11.5 7.2 11 5 7 305 20.6 0.2 21.3 19.9 01/03/2006 14:20:00 9.6 0.8 11.5 7.2 9.5 0.8 11.8 7.6 14 5 13 305 20.9 0.2 21.9 20.7 01/03/2006 14:30:00 10.3 0.9 12.2 7.6 10.1 1 12.6 7.6 15 5 10 305 21.7 0.3 22.2 20.4 01/03/2006 14:40:00 10.4 0.8 12.2 8.4 10.2 0.9 12.2 8 19 5 18 305 21.4 0.8 22.2 18.7 01/03/2006 14:50:00 10 1.2 13 6.1 10 1.3 12.6 6.5 18 5 24 305 21.2 0.4 22.2 19.9 01/03/2006 15:00:00 10.3 1.1 13.3 7.6 10.2 1.1 13 7.6 20 6 19 305 21.2 0.2 21.9 20.7 01/03/2006 15:10:00 10.2 1 12.6 8 10.1 1 12.6 8 25 5 31 305 21.7 0.6 23.1 20.7 01/03/2006 15:20:00 9.9 1.3 12.2 6.8 9.8 1.3 12.2 6.8 19 5 20 305 20.9 0.5 21.9 19 01/03/2006 15:30:00 10.6 0.9 12.6 8 10.4 1 12.2 7.6 18 5 13 305 21.3 0.1 21.9 20.1 01/03/2006 15:40:00 10.1 0.8 12.2 8 10 0.9 12.2 7.6 20 5 23 305 19.8 1.8 21.3 16.2 01/03/2006 15:50:00 9.8 0.9 12.6 7.6 9.7 1 12.6 6.8 15 5 13 305 16.4 0.2 17 15.9 01/03/2006 16:00:00 10.4 1 12.6 7.2 10.4 1 13.3 7.6 19 5 24 305 16.2 0.2 17 15.9 01/03/2006 16:10:00 10.2 0.9 12.2 7.6 10 1 12.2 7.6 16 4 20 305 16.2 0.2 17 15.9 01/03/2006 16:20:00 10.4 0.8 12.2 7.6 10.3 0.9 12.2 8 17 6 8 305 15.8 0.3 17 15.3 01/03/2006 16:30:00 10.3 0.8 12.6 8.4 10.2 0.9 12.6 8 19 6 28 305 15.4 0.3 16.5 14.8 01/03/2006 16:40:00 9.9 1 12.2 6.8 9.8 1 11.8 6.8 19 6 16 305 15.3 0.5 16.7 14.5 01/03/2006 16:50:00 9.2 1 11.8 6.8 9.1 1 11.8 6.8 18 6 17 305 16.2 0.4 17 13.2 01/03/2006 17:00:00 8.4 0.9 10.3 6.1 8.2 0.9 10.3 6.1 24 6 15 305 15.9 0.3 16.7 15.3 01/03/2006 17:10:00 8.3 0.9 9.9 6.1 8.1 0.9 9.9 6.1 23 5 19 305 15.4 0.5 16.5 14.8 01/03/2006 17:20:00 8.3 0.9 10.7 5.7 8.2 0.9 10.3 5.7 24 6 26 305 14.9 0.4 15.6 14 01/03/2006 17:30:00 8.5 1 10.7 6.5 8.2 1 10.3 5.7 27 7 25 305 14.8 1.1 16.2 12.4 01/03/2006 17:40:00 8.7 0.9 10.7 6.1 8.7 1 10.7 6.1 22 8 29 305 16 0.7 19 15.3 01/03/2006 17:50:00 7.7 0.8 9.5 6.1 7.5 0.8 9.9 5.3 26 6 19 305 19.2 0.7 20.1 15.3 01/03/2006 18:00:00 7.2 1 9.9 4.9 7 0.9 9.9 4.9 25 6 29 305 18.8 0.8 19.6 16.7 01/03/2006 18:10:00 8.2 1 10.3 5.7 8.1 0.9 10.3 6.1 24 7 33 305 17.5 0.5 19 15.9 01/03/2006 18:20:00 7.5 0.9 9.5 5.7 7.4 0.9 9.5 5.7 27 5 29 305 18.6 0.5 19.3 16.5 01/03/2006 18:30:00 6.3 1 8.4 4.2 6.3 0.9 8.4 4.2 20 8 11 305 18.8 0.5 19.9 17.9 01/03/2006 18:40:00 7.4 0.8 9.5 5.7 7.3 0.8 9.1 5.3 19 6 17 305 17.8 0.4 18.4 15.3 01/03/2006 18:50:00 7 0.8 8.8 5.3 6.9 0.8 8.8 4.9 27 7 15 305 18.4 0.4 19 17.3 01/03/2006 19:00:00 7.7 1.1 9.5 4.9 7.6 1.1 9.9 4.9 20 5 19 305 18.4 0.4 19 17 01/03/2006 19:10:00 7.1 1 9.5 4.6 7 1.1 9.5 4.2 24 6 21 305 17.2 0.1 17.6 16.5 01/03/2006 19:20:00 7.8 1 9.9 5.3 7.6 1 9.9 5.3 19 5 21 305 18.1 0.7 19 16.7 01/03/2006 19:30:00 7.5 0.7 9.1 5.7 7.4 0.7 9.1 5.7 19 6 16 305 19.8 0.3 20.1 18.4 01/03/2006 19:40:00 7.6 0.9 9.5 5.3 7.5 1 9.5 5.3 26 7 22 305 20 0 20.1 19.6 01/03/2006 19:50:00 7.3 0.8 8.8 5.3 7.1 0.8 8.8 4.9 18 6 15 305 19.6 0.5 20.1 16.7 01/03/2006 20:00:00 7 0.9 8.8 4.6 6.8 0.9 9.1 4.2 30 8 34 305 20.4 1 21.6 17.3 01/03/2006 20:10:00 6.3 0.7 8 4.2 6.2 0.7 7.6 4.2 23 7 16 305 21.2 0.1 21.6 20.7 01/03/2006 20:20:00 6.2 0.8 8 4.2 6.1 0.8 8 4.2 20 6 24 305 21.1 0 21.6 20.7 01/03/2006 20:30:00 6.2 0.8 8 4.6 6.1 0.8 8.4 4.2 15 8 21 305 20.7 0 21.3 20.1 01/03/2006 20:40:00 6.8 0.6 8 4.9 6.6 0.6 8 4.9 15 5 17 305 20.4 0.3 21 18.4 01/03/2006 20:50:00 6.7 0.8 8.8 4.9 6.5 0.8 8.4 4.6 19 7 11 305 19.6 0.3 20.1 16.5 01/03/2006 21:00:00 5.6 0.7 7.2 3.8 5.5 0.7 7.2 4.2 11 8 19 305 19.3 0.2 19.6 18.7 01/03/2006 21:10:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 4.2 13 8 4 305 19.3 0.3 19.9 18.4 01/03/2006 21:20:00 4.9 0.6 6.5 3.4 4.9 0.6 6.1 3.4 14 5 13 305 19.5 0 19.9 18.7 01/03/2006 21:30:00 5.1 0.6 6.8 3.4 5 0.6 6.5 3.8 17 5 14 305 19.6 0 19.9 18.1 01/03/2006 21:40:00 4.2 0.4 4.9 3 4.1 0.4 5.3 3 16 8 16 305 19.5 0 19.6 19.3 01/03/2006 21:50:00 4.4 0.6 5.7 3.4 4.4 0.6 6.1 3.4 12 6 10 305 19 1.5 19.9 13.7 01/03/2006 22:00:00 4.1 0.6 5.7 3 4 0.6 5.7 2.6 13 7 14 305 19.9 0.1 20.4 19.3 01/03/2006 22:10:00 4.8 0.6 6.1 3.4 4.7 0.6 6.1 3.4 15 6 7 305 19.9 0.2 21 19.3 01/03/2006 22:20:00 4.5 0.4 5.7 3.4 4.4 0.4 5.3 3.4 14 8 14 305 20.8 0.1 21.6 20.1 01/03/2006 22:30:00 4.3 0.6 5.7 2.6 4.4 0.5 5.7 3 1 6 359 305 20.6 0.1 21.3 20.1 01/03/2006 22:40:00 4.3 0.5 5.7 3.4 4.2 0.5 5.7 3 1 6 3 305 20.8 0.3 21.6 20.1 01/03/2006 22:50:00 4.4 0.5 5.7 3.4 4.5 0.5 5.7 3 358 4 357 305 21.4 0.2 22.2 20.7 01/03/2006 23:00:00 4.3 0.5 5.3 3 4.3 0.5 5.7 3 356 5 357 305 21.4 0.2 21.9 20.7 01/03/2006 23:10:00 4 0.5 4.9 2.6 4 0.4 4.9 2.6 0 6 359 305 20.9 0.2 21.6 19.9 01/03/2006 23:20:00 3.8 0.4 4.9 3 3.9 0.4 4.9 2.6 359 6 4 305 20.9 0.6 21.9 16.5 01/03/2006 23:30:00 3.9 0.5 5.3 2.6 3.9 0.6 5.3 2.6 350 8 343 305 20 0.8 21 17.9 01/03/2006 23:40:00 4 0.5 5.3 2.6 4.1 0.5 5.3 2.6 353 9 353 305 19.3 0.1 19.6 18.7 01/03/2006 23:50:00 4 0.4 4.9 3 4 0.4 4.9 3 351 6 351 305 19.3 0 19.9 19 01/04/2006 00:00:00 4 0.4 4.9 3 4 0.4 4.9 2.6 349 5 348 305 19.6 0 20.1 19 01/04/2006 00:10:00 3.9 0.4 4.9 3 4.1 0.4 4.9 3 348 5 338 305 19.5 0.2 19.9 16.7 01/04/2006 00:20:00 3.7 0.4 4.6 2.6 3.8 0.5 4.6 2.3 354 6 352 305 19.3 0.2 19.9 19 01/04/2006 00:30:00 3.2 0.3 3.8 2.3 3.3 0.4 4.6 2.3 359 7 347 305 19.3 0.2 19.9 19 01/04/2006 00:40:00 3.4 0.5 4.6 2.3 3.4 0.5 4.2 1.9 4 6 357 305 19.1 0.5 19.6 17 01/04/2006 00:50:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 4 7 4 305 19.4 0 19.9 19 01/04/2006 01:00:00 3.3 0.3 4.2 2.6 3.4 0.4 4.2 2.3 12 7 12 305 19.6 0.1 20.1 18.7 01/04/2006 01:10:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 24 4 27 305 19.3 0.2 19.9 17.9 01/04/2006 01:20:00 3.3 0.4 4.2 1.9 3.3 0.4 4.2 2.3 24 5 24 305 19.5 0.2 19.9 17.9 01/04/2006 01:30:00 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.3 18 3 19 305 18.4 0.5 19.6 17.3 01/04/2006 01:40:00 2.1 0.3 3 1.5 2.2 0.3 3 1.5 23 5 27 305 19.2 0.2 19.9 18.7 01/04/2006 01:50:00 2 0.2 2.6 1.5 2 0.2 2.6 1.5 18 3 18 305 19.6 0 19.9 19 01/04/2006 02:00:00 1.8 0.3 2.6 1.1 1.8 0.3 2.6 1.1 10 10 344 305 19.9 0.6 21.3 19.3 01/04/2006 02:10:00 1.8 0.3 2.3 1.1 1.8 0.3 2.6 1.1 2 12 347 305 21.2 0.2 21.6 20.4 01/04/2006 02:20:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 1.1 21 5 28 305 21.4 0.1 21.9 19.6 01/04/2006 02:30:00 1.4 0.3 2.3 0.7 1.4 0.3 2.3 0.7 12 6 15 305 21.2 0.1 21.9 20.7 01/04/2006 02:40:00 2.1 0.3 3 1.5 2.1 0.3 3 1.5 6 4 8 305 20.9 0.1 21.6 20.1 01/04/2006 02:50:00 2.4 0.3 3 1.5 2.4 0.3 3 1.9 10 5 4 305 18.9 2.5 21.9 12.9 01/04/2006 03:00:00 1.8 0.4 3 0.7 1.8 0.4 3 0.7 14 7 13 305 15.8 0.3 16.5 15.1 01/04/2006 03:10:00 2.5 0.6 3.8 1.1 2.6 0.7 3.8 1.1 342 17 331 305 15.4 0.3 16.2 14.8 01/04/2006 03:20:00 3 0.3 3.4 2.3 3.1 0.3 3.8 2.3 323 5 326 305 16 0.5 17.9 15.1 01/04/2006 03:30:00 2.8 0.3 3.4 1.9 2.9 0.3 3.4 2.3 330 5 331 305 15.7 0.6 17.3 14.3 01/04/2006 03:40:00 2.5 0.3 3 1.9 2.5 0.3 3 1.9 329 3 335 305 14.7 0.4 15.6 13.2 01/04/2006 03:50:00 1.9 0.3 2.6 1.1 2 0.3 2.6 1.5 323 5 326 305 14.3 0.8 16.7 12.9 01/04/2006 04:00:00 1.2 0.4 1.9 0.4 1.3 0.5 2.3 0.4 328 8 332 305 15.5 0.5 16.5 13.4 01/04/2006 04:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 350 0 350 305 15.7 0.4 16.7 14.5 01/04/2006 04:20:00 1 0.2 1.5 0.4 0.9 0.3 1.5 0.4 351 2 350 305 15.6 0.5 16.7 14.3 01/04/2006 04:30:00 1.1 0.2 1.5 0.4 0.9 0.3 1.5 0.4 355 0 355 305 14.6 0.6 15.9 12.9 01/04/2006 04:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 354 0 355 305 15.4 0.4 16.5 14.5 01/04/2006 04:50:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 355 0 355 305 15.1 0.5 16.2 14.3 01/04/2006 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 355 0 305 305 14.5 1.1 17 6.9 01/04/2006 05:10:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 355 0 355 305 16.5 0.5 17.6 14.8 01/04/2006 05:20:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 355 0 355 305 16.7 0.5 17.9 14.5 01/04/2006 05:30:00 0.6 0.3 1.1 0.4 0.6 0.3 1.5 0.4 12 29 355 305 15.9 0.8 17.3 12.9 01/04/2006 05:40:00 0.7 0.2 1.1 0.4 0.8 0.2 1.1 0.4 60 0 61 305 16.3 0.3 17 14.5 01/04/2006 05:50:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 60 0 61 305 16 0.2 16.5 14.5 01/04/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 60 0 305 305 16.2 0 16.7 14.8 01/04/2006 06:10:00 0.7 0.3 1.1 0.4 0.8 0.3 1.1 0.4 69 15 61 305 16.2 0.2 16.5 14 01/04/2006 06:20:00 0.5 0.3 1.9 0.4 0.6 0.2 1.1 0.4 114 45 199 305 16.3 0.3 17 15.3 01/04/2006 06:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 125 36 80 305 14.3 2.1 17.3 11.6 01/04/2006 06:40:00 1.1 0.8 2.6 0.4 1.3 1 3 0.4 98 56 53 305 13.2 0.2 14 11.6 01/04/2006 06:50:00 1.9 0.7 3.4 0.4 2.2 0.6 3.4 0.4 54 9 42 305 15.1 0.8 15.6 10.8 01/04/2006 07:00:00 1.6 0.6 3 0.4 1.7 0.5 3 0.7 52 5 47 305 15.6 0.1 15.9 14.8 01/04/2006 07:10:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 110 82 64 305 15.7 0 15.9 15.3 01/04/2006 07:20:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 296 49 248 305 15 0.5 15.6 14 01/04/2006 07:30:00 0.8 0.3 1.5 0.4 1 0.4 1.9 0.4 18 38 32 305 12 2.1 14.3 7.4 01/04/2006 07:40:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 7 15 341 305 10.5 0.8 12.1 8.9 01/04/2006 07:50:00 1.4 1 3.4 0.4 1.6 1 3.4 0.4 153 86 203 305 11.3 0.5 12.4 9.7 01/04/2006 08:00:00 1.9 0.6 3.4 0.4 1.7 0.6 3 0.4 234 17 251 305 11.2 0.4 12.1 10.2 01/04/2006 08:10:00 3.8 1.7 6.5 0.4 2.7 1.3 5.7 0.4 263 20 261 305 10.5 0.3 11.3 10 01/04/2006 08:20:00 4.2 0.7 6.1 2.3 3.4 0.7 5.3 1.9 271 18 279 305 9.8 0.4 10.5 8.9 01/04/2006 08:30:00 3.5 1 6.1 1.5 2.8 1 5.7 1.1 270 18 249 305 8.9 0.2 9.5 8.2 01/04/2006 08:40:00 2.8 0.8 4.9 1.5 2.3 0.7 4.6 1.1 274 23 253 305 8.6 0.7 9.5 2.2 01/04/2006 08:50:00 1.5 0.6 2.6 0.4 1.5 0.5 2.6 0.4 305 28 281 305 8.6 0.3 8.9 7.7 01/04/2006 09:00:00 1.3 0.5 2.3 0.4 1.8 0.4 2.6 0.4 31 21 24 305 7.8 0.2 8.4 7.2 01/04/2006 09:10:00 1.6 0.5 2.6 0.4 1.9 0.5 3 0.7 32 11 43 305 8.2 0.2 8.7 7.7 01/04/2006 09:20:00 1.1 0.4 1.9 0.4 1.3 0.5 2.3 0.4 65 11 46 305 8.8 0.5 9.7 7.9 01/04/2006 09:30:00 0.7 0.5 2.3 0.4 0.8 0.6 2.3 0.4 44 15 38 305 9 0.1 9.5 8.7 01/04/2006 09:40:00 2.4 0.8 4.2 0.7 2.5 0.7 3.8 0.7 86 18 94 305 8.4 0.4 9.2 6.7 01/04/2006 09:50:00 2.3 0.6 3.8 0.7 2.5 0.5 3.8 1.5 95 16 101 305 8.8 0.2 9.2 7.9 01/04/2006 10:00:00 2.5 0.6 3.4 0.7 2.5 0.4 3.4 1.5 100 8 124 305 8.5 0.1 9.2 8.2 01/04/2006 10:10:00 2.4 0.6 3.8 1.1 2.4 0.6 3.8 1.1 99 9 88 305 9.1 0.2 9.5 8.2 01/04/2006 10:20:00 3.2 0.6 4.2 1.9 2.9 0.6 3.8 1.5 103 5 102 305 8.9 0.3 9.5 7.9 01/04/2006 10:30:00 4 0.4 4.9 3 3.8 0.4 4.6 2.6 105 4 110 305 8 0.5 8.7 5.4 01/04/2006 10:40:00 4.1 0.5 4.9 1.9 3.9 0.4 4.6 2.6 100 6 110 305 6.3 0.7 8.2 3.7 01/04/2006 10:50:00 3.8 0.4 4.6 2.6 3.4 0.4 4.6 2.3 96 5 91 305 1.9 2.7 7.4 -11.5 01/04/2006 11:00:00 3.6 0.4 4.9 2.3 3.1 0.4 4.2 2.3 93 5 95 305 5.6 9.1 21.9 -3.8 01/04/2006 11:10:00 3.6 0.4 4.6 2.6 3.3 0.4 4.2 2.3 79 6 90 305 11.8 8 21.9 -1.8 01/04/2006 11:20:00 3.8 0.5 5.3 2.6 3.5 0.5 4.9 2.3 77 6 86 305 14.2 7 22.5 -18.6 01/04/2006 11:30:00 3.5 0.6 4.9 1.9 3.3 0.5 4.2 1.9 79 12 87 305 14 7 24.3 -9 01/04/2006 11:40:00 3.9 0.6 4.9 2.6 3.6 0.5 4.6 2.3 83 8 87 305 16.9 6.4 24.6 -8.8 01/04/2006 11:50:00 4.2 0.3 4.9 3.4 4 0.3 4.6 3 75 5 75 305 20.8 4.2 22.8 -2.9 01/04/2006 12:00:00 4.3 0.4 5.3 3.4 4.1 0.4 4.9 3 74 3 71 305 20.5 1.9 22.2 -1.8 01/04/2006 12:10:00 3.8 0.3 4.6 3 3.6 0.4 4.6 3 74 3 76 305 15.1 8 24 -9.6 01/04/2006 12:20:00 3.6 0.3 4.2 3 3.4 0.3 4.2 2.6 70 3 66 305 15.3 10.4 26.4 -6.2 01/04/2006 12:30:00 3.5 0.5 4.6 1.9 3.3 0.5 4.2 1.9 67 9 72 305 11.4 5.4 19.3 -4.5 01/04/2006 12:40:00 3.7 0.5 4.9 2.3 3.5 0.6 4.6 1.5 60 6 54 305 12.5 5.4 19.9 -18.1 01/04/2006 12:50:00 4 0.4 4.6 3 4 0.4 4.9 3 53 6 57 305 10.6 6.4 19.6 -18.8 01/04/2006 13:00:00 3.7 0.3 4.6 3 3.7 0.4 4.6 2.6 44 5 47 305 8.9 7.6 17.9 -18.8 01/04/2006 13:10:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 36 5 43 305 9.9 4.7 15.9 -12.5 01/04/2006 13:20:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 39 9 37 305 10.8 5.6 18.4 -15 01/04/2006 13:30:00 3.7 0.3 4.6 2.3 3.7 0.3 4.2 2.6 45 6 44 305 12.3 3.7 17.9 -14.3 01/04/2006 13:40:00 3.7 0.3 4.6 3 3.7 0.3 4.6 2.6 41 5 42 305 10.5 6.2 18.1 -3.8 01/04/2006 13:50:00 4.1 0.4 4.9 3 4 0.4 4.9 3 46 6 37 305 14 4.4 19.3 -3.1 01/04/2006 14:00:00 4.2 0.4 4.9 3 4.2 0.4 5.3 3.4 46 6 42 305 13.6 5 19.9 -3.1 01/04/2006 14:10:00 4.5 0.4 5.3 3.4 4.6 0.5 5.3 3.4 43 4 38 305 15.2 4 20.1 -4 01/04/2006 14:20:00 4.7 0.4 5.7 3.4 4.8 0.5 5.7 3.4 41 5 40 305 15.9 3.2 20.4 -3.3 01/04/2006 14:30:00 5.2 0.4 5.7 4.2 5.2 0.4 6.1 3.8 41 3 41 305 15.6 3.5 20.4 -0.6 01/04/2006 14:40:00 5.1 0.3 6.1 4.6 5.2 0.3 6.1 3.8 41 4 39 305 15.7 3.2 19.9 -3.1 01/04/2006 14:50:00 4.7 0.5 5.7 3.4 4.8 0.5 5.7 3 45 6 48 305 14.7 4.7 21 -2.9 01/04/2006 15:00:00 4.8 0.4 5.7 3.4 4.7 0.5 5.7 3.4 40 4 34 305 16.2 4.4 22.2 -14.3 01/04/2006 15:10:00 5.2 0.4 6.1 4.2 5.2 0.4 6.1 4.2 39 3 31 305 15.7 3.8 20.4 -2.4 01/04/2006 15:20:00 5.2 0.4 6.1 4.2 5.3 0.4 6.1 3.8 37 3 42 305 16.1 3.4 21.3 -1.1 01/04/2006 15:30:00 5.1 0.4 6.1 4.2 5.2 0.4 6.5 4.2 41 4 48 305 16.3 3.1 21.6 -0.6 01/04/2006 15:40:00 4.8 0.3 5.3 3.8 4.9 0.4 5.7 3.8 44 4 43 305 17.6 1.3 21.3 -0.4 01/04/2006 15:50:00 4.4 0.4 5.3 3.4 4.5 0.4 5.3 3.4 41 6 44 305 16.5 0.6 18.4 12.1 01/04/2006 16:00:00 4.3 0.4 5.3 3 4.4 0.5 5.3 3.4 37 6 42 305 17.5 1.6 19 -0.4 01/04/2006 16:10:00 4.7 0.3 5.3 3.8 4.8 0.3 5.7 3.8 49 4 58 305 17.9 0.4 19 15.3 01/04/2006 16:20:00 4.5 0.4 5.3 3.4 4.6 0.4 5.3 3.4 51 4 53 305 17.2 0.3 17.9 15.9 01/04/2006 16:30:00 4.5 0.5 5.7 3 4.6 0.5 5.7 3 52 4 52 305 16.7 1.3 17.9 -0.6 01/04/2006 16:40:00 4.8 0.3 5.7 4.2 4.9 0.4 5.7 3.8 55 4 48 305 15.2 1.4 17.9 10.5 01/04/2006 16:50:00 5.1 0.3 5.7 4.2 5.2 0.3 6.1 4.6 54 4 55 305 15.6 1.4 18.4 12.9 01/04/2006 17:00:00 4.8 0.5 6.1 3.4 4.7 0.5 6.1 3.4 59 6 52 305 17.5 1.6 19.6 1.7 01/04/2006 17:10:00 4.6 0.4 5.7 3.4 4.6 0.4 5.7 3.4 55 7 57 305 18.1 3.4 22.2 -0.6 01/04/2006 17:20:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3.4 55 6 57 305 18.9 2.5 21.3 0.1 01/04/2006 17:30:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.8 64 3 65 305 18.4 2.5 20.1 1.7 01/04/2006 17:40:00 4.4 0.4 5.3 3.4 4.3 0.5 5.3 3 62 4 59 305 17.7 3.5 20.7 -1.8 01/04/2006 17:50:00 4 0.4 4.9 2.6 3.8 0.5 4.6 2.6 65 4 67 305 18 2.1 19.6 -2.9 01/04/2006 18:00:00 3.9 0.4 4.9 3 3.8 0.4 4.9 2.6 63 4 67 305 18.6 1.9 19.9 3.4 01/04/2006 18:10:00 4.5 0.4 5.3 3.4 4.4 0.4 5.3 3 58 4 60 305 18.4 1.4 19.6 4.4 01/04/2006 18:20:00 4.3 0.5 5.3 3.4 4.2 0.5 5.3 3 56 3 53 305 17.4 2.6 19.6 -2.7 01/04/2006 18:30:00 4.8 0.3 5.3 3.8 4.9 0.4 5.7 3.8 57 3 53 305 17.7 1.8 19.9 4.2 01/04/2006 18:40:00 4.5 0.4 5.7 3.4 4.6 0.5 5.7 3.4 57 5 52 305 18.4 1.7 19.9 -1.8 01/04/2006 18:50:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 52 5 51 305 18.4 1.4 19.6 4.4 01/04/2006 19:00:00 4.7 0.4 5.3 3.8 4.7 0.4 5.7 3.8 50 5 56 305 17.8 1.8 19.3 2.9 01/04/2006 19:10:00 4.6 0.4 5.7 3.4 4.6 0.5 5.7 3.4 50 4 44 305 17.7 1 19 15.1 01/04/2006 19:20:00 4.9 0.4 5.7 3.8 4.9 0.4 5.7 3.8 45 3 43 305 17.4 1.1 19 12.1 01/04/2006 19:30:00 5 0.5 6.5 3.8 4.9 0.5 6.5 3.8 41 5 36 305 17.5 1.2 19 8.4 01/04/2006 19:40:00 5.9 0.5 7.2 3.8 5.9 0.6 7.2 4.2 43 4 41 305 17.2 2.4 19.6 -5.6 01/04/2006 19:50:00 5.9 0.5 6.8 4.6 5.8 0.5 7.2 4.6 42 5 40 305 16.9 1.4 18.4 13.2 01/04/2006 20:00:00 6.1 0.4 6.8 4.6 6 0.5 7.2 4.6 43 4 44 305 15.1 2.5 17.6 -3.3 01/04/2006 20:10:00 5.9 0.5 6.8 4.6 5.8 0.5 6.8 4.2 43 4 44 305 11.8 7.3 19 -4.5 01/04/2006 20:20:00 5.6 0.5 6.5 4.2 5.5 0.6 6.8 4.2 40 4 41 305 12.4 7 18.7 -3.8 01/04/2006 20:30:00 5.1 0.5 6.5 4.2 5 0.5 6.5 3.8 38 5 46 305 2.6 11.8 19.6 -18.1 01/04/2006 20:40:00 4.7 0.5 6.5 3.4 4.6 0.6 6.1 3.4 34 7 35 305 12 3.4 19 -13.3 01/04/2006 20:50:00 5 0.5 6.1 3.4 5 0.6 6.5 3.8 26 6 23 305 11.1 3.1 15.3 -14.4 01/04/2006 21:00:00 5.6 0.6 6.8 3.8 5.5 0.6 6.8 4.2 20 5 21 305 14 7 26.7 -17.5 01/04/2006 21:10:00 5.5 0.9 7.2 3.4 5.3 1 7.2 3 22 5 30 305 20.6 1.5 25.2 15.1 01/04/2006 21:20:00 5.7 0.6 6.8 4.6 5.6 0.6 7.2 4.2 21 6 25 305 23.7 1.1 25.5 20.4 01/04/2006 21:30:00 5.4 0.7 6.8 3.8 5.3 0.7 6.8 3.4 21 5 16 305 22.3 2.6 24.9 -16 01/04/2006 21:40:00 5.6 0.7 7.2 3.8 5.5 0.6 6.8 4.2 19 6 14 305 19.6 6.4 23.4 -17.9 01/04/2006 21:50:00 5.5 0.6 7.2 4.2 5.5 0.6 6.8 3.8 19 5 14 305 16.8 9.1 22.2 -15.2 01/04/2006 22:00:00 4.9 0.5 6.1 3.8 4.8 0.5 6.1 3.4 17 5 16 305 -9.4 4.5 -3.3 -16.9 01/04/2006 22:10:00 4.9 0.6 6.1 3.4 4.9 0.6 6.5 3.4 16 5 19 305 -3.6 0.6 -2.4 -6.4 01/04/2006 22:20:00 4.9 0.5 6.1 3.8 4.9 0.5 6.1 3.4 18 6 19 305 -2.4 2.5 3.2 -6.4 01/04/2006 22:30:00 5.6 0.6 6.8 3.8 5.5 0.6 7.6 4.2 16 6 30 305 0.9 0.9 2.2 -2.2 01/04/2006 22:40:00 5.9 0.5 7.2 4.9 5.8 0.5 6.8 4.6 17 6 19 305 -3 2.1 2.2 -7.3 01/04/2006 22:50:00 6.2 0.7 8 4.6 6.1 0.8 7.6 4.6 15 6 16 305 -5.2 1 -3.1 -9 01/04/2006 23:00:00 6.3 0.6 7.6 4.2 6.2 0.6 7.2 4.2 15 5 10 305 -2.8 2 -0.6 -9.6 01/04/2006 23:10:00 5.3 0.7 7.2 3.8 5.2 0.7 7.2 3.8 17 5 9 305 -8.8 4.7 -2.4 -14.6 01/04/2006 23:20:00 5.6 0.8 7.6 3.8 5.5 0.8 7.2 3.8 17 7 11 305 -2.8 7.3 4.9 -14.6 01/04/2006 23:30:00 6.2 0.8 7.6 4.6 6.1 0.8 8 4.2 13 5 8 305 1.4 3.1 4.9 -19.2 01/04/2006 23:40:00 6.6 0.8 8.4 4.9 6.5 0.8 8.4 4.6 9 5 14 305 -1.9 1 0.1 -6 01/04/2006 23:50:00 6.9 0.5 8 5.3 6.9 0.6 8.4 4.9 11 4 14 305 0 4.2 7.9 -19.2 01/05/2006 00:00:00 6.1 0.6 7.2 4.2 6 0.7 7.2 4.2 11 6 6 305 6.5 1.7 9.5 -5.8 01/05/2006 00:10:00 6.1 0.7 7.6 4.2 6 0.7 7.6 4.2 14 6 7 305 -7.4 9.9 6.9 -19.3 01/05/2006 00:20:00 6.1 0.6 7.2 4.6 6 0.6 7.2 4.6 24 5 21 305 -6.9 3.2 -2.4 -19.3 01/05/2006 00:30:00 6.5 0.6 8 4.9 6.4 0.6 7.6 4.9 22 6 21 305 -5.9 2.6 -3.3 -19.2 01/05/2006 00:40:00 6.9 0.6 8.4 4.9 6.8 0.6 8 4.9 24 7 18 305 -4.4 3.4 11.8 -18.4 01/05/2006 00:50:00 6.6 0.7 8.4 4.9 6.6 0.8 8 4.9 21 7 23 305 8.3 1.6 12.4 2.9 01/05/2006 01:00:00 6 0.8 8 3.8 5.9 0.8 7.6 3.8 16 6 11 305 5.4 1.5 8.4 -1.1 01/05/2006 01:10:00 6 0.5 7.2 4.2 5.9 0.5 7.2 4.6 20 5 20 305 4.7 1.4 9.2 0.1 01/05/2006 01:20:00 5.4 0.6 6.8 3.8 5.4 0.6 6.8 4.2 19 6 21 305 5.8 1.8 9.7 1 01/05/2006 01:30:00 5.7 0.7 7.2 4.2 5.7 0.7 7.6 3.8 16 5 19 305 5.6 1.6 9.7 1 01/05/2006 01:40:00 6.1 0.5 7.6 4.6 6 0.5 7.2 4.6 18 5 12 305 4.4 1.3 7.2 0.1 01/05/2006 01:50:00 5.7 0.7 7.2 3.8 5.8 0.7 7.2 4.2 13 8 5 305 6.2 2 9.7 0.3 01/05/2006 02:00:00 6 0.6 7.2 4.2 6 0.6 7.2 4.6 10 5 10 305 5.2 2.2 8.9 -3.8 01/05/2006 02:10:00 6.1 0.6 7.6 4.2 6.1 0.6 7.6 4.2 11 4 13 305 4.1 2.1 7.9 -2.2 01/05/2006 02:20:00 6.2 0.7 8 4.6 6.1 0.7 8 4.2 15 5 13 305 6.1 2.2 10 0.3 01/05/2006 02:30:00 6.3 0.6 8.4 4.6 6.3 0.7 8 4.6 15 7 22 305 9.5 1 11.6 4.2 01/05/2006 02:40:00 6.4 0.6 7.6 4.6 6.3 0.6 8 4.6 20 5 20 305 10 1 12.1 6.9 01/05/2006 02:50:00 6.5 0.8 8 4.6 6.5 0.8 8 4.2 17 5 18 305 9.5 1.6 11.8 1 01/05/2006 03:00:00 6.6 0.8 8 4.6 6.5 0.8 8 4.6 17 5 13 305 8.9 1.5 11.3 0.1 01/05/2006 03:10:00 6.4 0.6 8 4.9 6.4 0.6 8.4 4.6 16 5 19 305 9.8 1.6 12.4 3.7 01/05/2006 03:20:00 5.9 0.6 7.2 4.2 5.9 0.6 7.6 4.2 12 5 17 305 10.4 1.3 12.4 3.2 01/05/2006 03:30:00 5.9 0.8 7.6 4.2 5.9 0.8 7.6 4.2 12 6 10 305 10.3 0.9 12.4 5.9 01/05/2006 03:40:00 5.7 0.7 6.8 3.8 5.8 0.6 7.2 3.8 8 4 11 305 9 1.1 11 2.5 01/05/2006 03:50:00 5.2 0.8 7.2 3 5.2 0.7 7.2 3.4 11 7 15 305 8.7 1.4 11.6 3.2 01/05/2006 04:00:00 6.1 0.9 7.6 3.8 6.1 0.9 7.6 3.8 8 6 8 305 8.1 1 11.3 4.9 01/05/2006 04:10:00 6.2 0.7 7.6 4.2 6.3 0.7 8 4.6 13 6 14 305 12.3 2.4 15.9 3.2 01/05/2006 04:20:00 6.5 0.8 8.4 4.6 6.5 0.9 8.4 4.6 8 6 15 305 13.2 1.8 15.9 2.9 01/05/2006 04:30:00 6.3 0.8 8 4.6 6.3 0.8 8 4.6 7 6 8 305 6.7 2 13.7 -0.6 01/05/2006 04:40:00 6.7 0.7 8.4 4.6 6.7 0.7 8.4 4.2 4 6 9 305 -1.3 5.6 7.7 -8.8 01/05/2006 04:50:00 6.5 1 8.4 3.8 6.6 1 8.4 3.8 6 6 14 305 5.1 3.2 8.7 -7.7 01/05/2006 05:00:00 7.4 1 9.5 5.3 7.2 1 9.1 5.3 9 5 9 305 8 1.6 11 -1.3 01/05/2006 05:10:00 7.6 0.9 9.5 5.3 7.6 0.9 9.5 5.3 9 7 2 305 8.2 1 10.8 2 01/05/2006 05:20:00 7.8 0.8 9.5 4.6 7.8 0.8 9.5 4.9 3 5 2 305 12.8 1.5 15.3 5.6 01/05/2006 05:30:00 7.4 0.9 9.9 5.3 7.4 1 9.9 5.3 6 7 2 305 16.7 1.6 19.3 8.7 01/05/2006 05:40:00 7.8 1 11.1 5.7 7.9 1 10.7 4.9 7 5 8 305 17.9 1.7 20.4 8.2 01/05/2006 05:50:00 8.3 0.9 10.3 5.7 8.3 0.9 9.9 6.1 5 5 6 305 17.9 2 19.9 8.2 01/05/2006 06:00:00 8.4 0.9 10.3 6.1 8.4 0.9 10.3 5.7 8 6 14 305 17.4 2.3 19.6 5.4 01/05/2006 06:10:00 8.6 0.8 10.3 6.5 8.5 0.9 10.7 6.1 7 5 4 305 17.6 2.8 20.7 -2 01/05/2006 06:20:00 8.9 0.9 11.1 6.1 8.8 0.9 10.7 6.8 9 5 12 305 17.6 1.7 20.7 6.7 01/05/2006 06:30:00 8.8 1.2 11.1 6.1 8.8 1.3 11.5 5.7 11 6 5 305 18.9 1.8 21.3 7.2 01/05/2006 06:40:00 9 1.3 12.2 6.1 9 1.2 12.2 6.1 11 6 12 305 14.3 4.7 21 -16.4 01/05/2006 06:50:00 10.3 0.9 12.2 7.2 10.3 1 12.2 7.6 11 5 14 305 7.9 7.3 14.3 -16.6 01/05/2006 07:00:00 10.1 1 12.6 7.6 10.1 1.1 12.2 7.2 14 5 8 305 -0.4 5 14.5 -10.7 01/05/2006 07:10:00 9.5 0.9 11.8 6.8 9.5 0.9 11.8 7.2 17 5 13 305 13 4.7 19.3 0.6 01/05/2006 07:20:00 9.1 1.1 11.8 6.8 9 1.2 12.2 6.5 13 6 17 305 16.3 2.2 20.7 3.4 01/05/2006 07:30:00 10.5 0.9 12.6 8 10.4 1 12.6 8 14 6 16 305 17.8 1.7 20.7 5.6 01/05/2006 07:40:00 10.4 1 12.6 7.6 10.3 1.1 13 7.6 12 6 18 305 14.4 2.6 19.9 4.7 01/05/2006 07:50:00 9.9 1.1 12.2 7.2 9.8 1.1 12.6 6.8 11 6 10 305 16.5 1.8 19.3 3.7 01/05/2006 08:00:00 10 1.1 13 6.8 10 1.1 12.6 7.6 10 6 5 305 17.4 1.9 19 2.7 01/05/2006 08:10:00 9.6 1.3 12.2 6.1 9.6 1.3 12.2 6.1 11 5 18 305 18.3 1.3 21.9 6.4 01/05/2006 08:20:00 10.1 0.9 12.2 7.2 10 0.9 12.2 7.6 13 5 12 305 18 2.3 20.7 3.2 01/05/2006 08:30:00 10.3 0.9 12.2 7.2 10.2 1 12.2 6.8 15 5 14 305 18.1 2.5 21.9 3.7 01/05/2006 08:40:00 9.9 0.9 11.8 7.6 9.8 0.9 11.8 7.2 14 5 11 305 18.6 1.7 21.3 3.9 01/05/2006 08:50:00 10 0.8 11.8 8 10 0.8 11.8 8 14 5 15 305 18.4 2 21 2.7 01/05/2006 09:00:00 9.6 1 12.2 7.2 9.5 1.1 12.2 6.8 14 5 21 305 18.4 2.1 21.6 2 01/05/2006 09:10:00 10.6 1 12.6 8 10.7 1.1 13 8 10 5 12 305 18.6 1.8 22.2 2.2 01/05/2006 09:20:00 10.8 0.6 12.6 9.1 10.9 0.7 12.6 8.4 9 5 5 305 15.6 4.4 20.1 -3.3 01/05/2006 09:30:00 9.6 0.9 11.5 6.8 9.6 0.9 11.5 6.8 9 5 5 305 18.8 5 23.7 6.1 01/05/2006 09:40:00 9.1 1 11.5 6.8 9 1 11.1 6.8 8 5 16 305 22.4 1 25.8 17.6 01/05/2006 09:50:00 8.8 0.9 10.7 6.5 8.7 1 11.5 5.7 9 5 12 305 24.6 1.3 27.3 15.3 01/05/2006 10:00:00 9 0.8 11.1 6.8 9 0.9 11.1 6.5 11 6 13 305 25.3 0.9 27.3 20.1 01/05/2006 10:10:00 8.9 1.3 11.8 5.3 8.7 1.3 11.5 5.7 26 6 29 305 25.3 1 27.6 21.9 01/05/2006 10:20:00 11.2 1.1 13.3 8 11 1.1 13.3 8 24 5 18 305 24.5 1.5 27 15.3 01/05/2006 10:30:00 10.5 0.8 12.6 8.4 10.5 0.9 12.6 8 28 6 23 305 12.6 1.6 24.9 10.5 01/05/2006 10:40:00 11.7 1 13.7 7.6 11.5 1.1 13.7 8 29 5 28 305 11.9 0.1 12.4 10.2 01/05/2006 10:50:00 10.6 1.1 13.3 8 10.4 1.1 13.3 8 31 6 33 305 16 5 24 11.8 01/05/2006 11:00:00 11 1.1 13.7 8.4 10.9 1.1 13.3 8.4 32 6 40 305 21.8 3.4 26.1 11.8 01/05/2006 11:10:00 10 1.3 13.3 6.8 9.9 1.3 13 6.5 34 6 40 305 22.5 2.1 26.1 11.6 01/05/2006 11:20:00 10.3 1.2 12.6 7.2 10.1 1.2 12.6 6.8 31 6 27 305 22.6 2 26.4 11.8 01/05/2006 11:30:00 10.5 1.4 13.7 6.5 10.3 1.4 13.7 6.5 32 7 37 305 23.1 2.3 27 11.8 01/05/2006 11:40:00 10.4 1.4 13.7 7.2 10.3 1.4 13.3 7.2 31 7 29 305 23.5 3.2 27.3 11.3 01/05/2006 11:50:00 10.7 1.5 13 6.8 10.4 1.5 13 7.2 30 6 32 305 23.8 2.6 27.6 11.8 01/05/2006 12:00:00 10 1 12.2 7.6 9.9 1 12.6 7.6 33 6 30 305 23 3.1 27.3 2.7 01/05/2006 12:10:00 10.3 1 12.6 7.2 10.3 1.1 13.3 7.6 33 6 37 305 23.4 2.8 27.6 11.6 01/05/2006 12:20:00 9.6 1.1 12.2 7.2 9.5 1.1 12.6 6.8 32 7 38 305 23.4 2.5 27.6 11.6 01/05/2006 12:30:00 11.2 0.8 13.3 9.1 11.1 0.8 13.3 8.8 32 5 35 305 23.7 2.4 27 8.2 01/05/2006 12:40:00 10.8 1.1 13.3 8 10.7 1.1 13.3 8.4 33 6 29 305 22.3 4.5 27.3 10.8 01/05/2006 12:50:00 10.8 1.2 13.7 8 10.7 1.3 13.7 8 30 5 32 305 24.2 1.5 27 16.2 01/05/2006 13:00:00 11.5 0.9 13.3 8.8 11.4 0.9 13.3 9.1 32 5 30 305 24.3 1.1 26.1 20.1 01/05/2006 13:10:00 11.5 0.8 13.7 9.1 11.4 0.8 13.7 8.8 29 5 31 305 23.7 2 26.7 17 01/05/2006 13:20:00 11.1 0.9 13.7 8.8 10.9 1 13 8.4 30 6 30 305 14.5 4 26.1 11.8 01/05/2006 13:30:00 10.9 1.1 13.3 8.4 10.7 1.1 13.3 8 33 6 38 305 13 0.3 18.7 12.6 01/05/2006 13:40:00 10.7 1.1 13 8 10.5 1 12.6 7.6 32 5 28 305 22.8 3.4 25.8 12.9 01/05/2006 13:50:00 11.3 1.2 13.3 7.6 11 1.2 13.7 8 32 6 28 305 23.6 2 26.4 13.4 01/05/2006 14:00:00 11.5 1.1 13.7 8.4 11.3 1.1 14.1 8.4 28 5 20 305 23.8 2.1 27.3 13.7 01/05/2006 14:10:00 10.6 1.3 13 7.2 10.5 1.2 13 8 29 6 32 305 23.9 2.4 27.9 13.4 01/05/2006 14:20:00 11.6 1.4 14.1 8 11.4 1.4 14.5 8.4 30 6 34 305 23.1 2 27.6 13.2 01/05/2006 14:30:00 11.3 1.2 13.7 8.4 11.1 1.1 13.7 8.4 34 6 32 305 24.3 2.2 28.2 14 01/05/2006 14:40:00 10.1 1 12.6 7.6 10 1 12.2 6.8 33 6 33 305 23.7 1.8 27 13.7 01/05/2006 14:50:00 10.1 1.1 13 7.6 9.9 1.1 12.2 7.2 31 6 29 305 26.4 5.2 30.7 12.4 01/05/2006 15:00:00 11.1 1.1 13.7 8.4 10.9 1.1 14.1 8 26 6 34 305 29.1 2.7 30.7 13.2 01/05/2006 15:10:00 10.7 1.1 13.3 7.6 10.6 1.1 13.3 8 32 5 35 305 28.1 1.7 30.7 13.2 01/05/2006 15:20:00 11.2 1 13.3 9.1 11.1 0.9 13.3 8.8 30 5 23 305 25 5.6 29.8 13.2 01/05/2006 15:30:00 11 1.2 14.5 8 10.9 1.2 14.1 7.6 32 6 30 305 8.3 9.5 25.8 -13.9 01/05/2006 15:40:00 11.6 1 14.1 8 11.5 1 13.7 7.6 34 5 35 305 23.4 8.3 32 -12.7 01/05/2006 15:50:00 10.5 1.2 13.3 8 10.4 1.2 13.7 8 34 6 35 305 20.3 7 27.9 -15 01/05/2006 16:00:00 11.6 1.1 14.1 8.8 11.5 1.2 14.9 8 33 5 30 305 20.3 5.2 27.9 -14.4 01/05/2006 16:10:00 11.4 1.1 14.5 8.4 11.4 1.1 14.5 7.6 35 6 31 305 21.3 5.9 30.1 -4.5 01/05/2006 16:20:00 11.3 1.3 14.1 8.4 11.2 1.2 14.1 8 35 6 33 305 17.5 8.7 31.7 -8.4 01/05/2006 16:30:00 10.9 1 13.3 8.4 10.7 1.1 13 7.6 36 6 33 305 15.4 11.3 32.3 -12.5 01/05/2006 16:40:00 10.8 1.4 14.1 8 10.7 1.5 14.1 8 35 6 34 305 25.7 5.6 32 1.5 01/05/2006 16:50:00 11.9 1.2 14.1 8.4 11.8 1.2 14.5 8.4 35 5 38 305 19.8 5.2 32 9.5 01/05/2006 17:00:00 11.7 1.2 15.6 8.8 11.5 1.3 16.1 8.8 36 6 36 305 23.9 9.9 35.9 12.4 01/05/2006 17:10:00 12 1.2 14.5 9.5 11.8 1.2 14.9 9.1 36 6 32 305 34.9 0.9 36.9 32 01/05/2006 17:20:00 11.1 1.3 14.1 8 10.9 1.2 13.7 8.4 34 6 30 305 32.3 3.7 36.9 23.4 01/05/2006 17:30:00 11.2 1 13.3 8.4 11.1 1 13.7 8.4 35 6 35 305 13.2 14.6 32.6 -7.9 01/05/2006 17:40:00 11.4 1.1 14.1 8.8 11.2 1.1 14.1 8.4 33 5 27 305 23.7 5 28.8 -4.2 01/05/2006 17:50:00 12 1.2 14.9 8.8 11.9 1.2 14.9 8.8 33 6 27 305 16.4 10.4 26.7 -11.7 01/05/2006 18:00:00 11.4 1 14.5 8.4 11.2 1 14.5 8.4 37 6 32 305 10.8 13.4 25.5 -12.9 01/05/2006 18:10:00 11 1.6 14.5 7.6 10.9 1.5 14.1 7.6 37 6 34 305 15.4 9.1 24.6 -15 01/05/2006 18:20:00 11.5 1 15.6 8.8 11.4 1 14.1 8.8 39 6 20 305 -2.3 8.7 17.3 -13.1 01/05/2006 18:30:00 12.9 1.2 16.8 9.9 12.7 1.2 17.2 10.3 36 6 39 305 8 4.4 11.3 -13.5 01/05/2006 18:40:00 12.6 1.1 15.6 9.9 12.5 1 14.9 9.5 37 5 26 305 7.4 6.4 11.8 -14.6 01/05/2006 18:50:00 10.9 1.2 13.7 8.4 10.8 1.2 13.7 8 37 6 32 305 9.7 4.2 13.2 -15 01/05/2006 19:00:00 10.8 1.1 13.7 7.6 10.6 1.1 13.7 8 33 6 30 305 12 0.8 14.3 9.5 01/05/2006 19:10:00 10.6 1.2 13.3 7.6 10.4 1.2 13.3 7.2 31 6 41 305 9.9 2.9 12.4 -10.9 01/05/2006 19:20:00 10.9 1.3 14.1 7.6 10.8 1.3 14.5 7.6 29 6 33 305 15.4 4.2 18.7 4.9 01/05/2006 19:30:00 10.6 1.1 13.3 8 10.5 1.1 13 7.6 28 6 20 305 14.3 4 18.1 -5.1 01/05/2006 19:40:00 10.2 1.2 13 6.8 10.1 1.2 12.6 7.2 33 6 36 305 8.3 2 12.1 -2.7 01/05/2006 19:50:00 11 1.4 14.5 8 10.8 1.5 14.5 7.2 34 6 35 305 9.1 5.9 14.8 -13.1 01/05/2006 20:00:00 11.6 1.3 14.9 8.4 11.5 1.3 15.3 8.4 39 5 40 305 8.9 10.8 27.6 -11.9 01/05/2006 20:10:00 11.5 1.3 14.5 8 11.4 1.3 15.3 8 37 5 43 305 12.8 10.8 35.9 -11.7 01/05/2006 20:20:00 10.2 1.5 14.9 7.6 10.1 1.5 14.9 7.2 36 6 34 305 29.4 8.7 39.6 7.4 01/05/2006 20:30:00 10.6 1.2 13.7 8.4 10.5 1.3 13.7 7.6 36 7 31 305 31.8 4.5 39.3 7.2 01/05/2006 20:40:00 10.9 1.2 14.9 8.4 10.7 1.2 14.9 8 35 6 33 305 29.5 5.9 36.6 11.8 01/05/2006 20:50:00 10.9 1.3 14.5 7.2 10.8 1.3 14.1 7.6 32 6 28 305 20.5 5.6 31 -11.7 01/05/2006 21:00:00 11.3 1.2 14.5 8 11.1 1.2 14.5 8 33 5 37 305 13.6 9.1 30.1 -10.9 01/05/2006 21:10:00 10.9 1.2 13.7 8 10.7 1.2 14.1 7.6 29 6 29 305 16 4.5 22.8 -3.1 01/05/2006 21:20:00 10.6 1.2 13.7 7.6 10.4 1.2 13.3 7.6 25 6 18 305 19.3 4.4 26.7 12.6 01/05/2006 21:30:00 10.3 1 13.3 7.2 10.1 1.1 12.6 7.2 18 7 14 305 22.3 2.3 26.7 14.8 01/05/2006 21:40:00 11 1.3 14.5 8 10.9 1.2 14.1 8 18 6 10 305 19 2.7 24.9 6.4 01/05/2006 21:50:00 11.3 1.3 13.7 7.6 11.1 1.3 13.7 7.2 18 6 9 305 9.7 8.3 20.4 -9 01/05/2006 22:00:00 11.1 1 13 8.4 11 1 13.3 8.8 27 6 27 305 18.8 2.6 23.4 2.7 01/05/2006 22:10:00 11.2 1.1 13.7 8.4 11.1 1.1 14.1 8.4 28 5 24 305 20.6 1.8 24.6 7.2 01/05/2006 22:20:00 10.9 1 13.3 8.4 10.8 1 13.3 8.8 25 5 23 305 20.6 1.5 24.3 14.3 01/05/2006 22:30:00 11.2 1 13.3 7.2 10.9 1.1 13.3 7.6 24 5 25 305 18.8 1 22.2 15.3 01/05/2006 22:40:00 10.8 1.1 13.3 7.6 10.6 1 13 7.6 25 5 23 305 17 3.8 21.3 -7.7 01/05/2006 22:50:00 10.5 1 13 8.4 10.3 1.1 13 7.6 25 6 29 305 14.5 5.9 20.7 -11.3 01/05/2006 23:00:00 10.4 1.1 13.3 8 10.3 1.1 13 8 22 6 28 305 18 0.8 21 16.7 01/05/2006 23:10:00 9.8 1.2 12.2 6.8 9.8 1.2 12.2 7.2 22 5 18 305 12.4 6.7 24.9 -1.8 01/05/2006 23:20:00 10.6 1.3 13.7 6.8 10.4 1.3 13.3 7.2 24 6 21 305 19.1 9.9 37.9 9.5 01/05/2006 23:30:00 10 1 12.6 7.2 9.9 1 12.6 7.6 22 6 25 305 30.6 5.2 38.9 11 01/05/2006 23:40:00 9.8 1.1 12.6 6.8 9.8 1.1 12.6 6.8 21 6 14 305 34.8 3.7 41 12.6 01/05/2006 23:50:00 9.5 1.1 13 7.2 9.3 1.1 13.3 6.5 22 5 23 305 38.2 2.7 43.1 23.4 01/06/2006 00:00:00 9.3 0.9 11.5 6.8 9.2 0.9 11.5 6.5 22 5 33 305 39.7 2.1 43.4 22.8 01/06/2006 00:10:00 9.5 0.9 11.5 7.6 9.4 0.9 11.5 7.6 16 5 18 305 35.5 4.5 41.3 8.4 01/06/2006 00:20:00 9.7 0.9 11.5 7.6 9.5 0.9 11.5 7.2 13 5 18 305 36.7 3.8 41.3 9.2 01/06/2006 00:30:00 9.6 0.8 11.8 7.6 9.4 0.9 11.5 7.6 14 5 13 305 37.3 5.9 43.4 0.6 01/06/2006 00:40:00 9.7 0.7 11.5 8 9.6 0.8 11.8 7.6 14 5 12 305 33.6 7.6 43.1 -8.6 01/06/2006 00:50:00 10 1 12.2 7.2 9.8 1.1 11.8 7.2 19 5 21 305 30.5 6.4 36.2 -8.2 01/06/2006 01:00:00 10.9 1 13.3 8.4 10.7 1 13.3 8 20 5 15 305 31.4 3.7 36.9 6.4 01/06/2006 01:10:00 10.9 1.1 13.3 8.4 10.8 1.1 13.3 7.6 18 5 23 305 30.3 3.5 34.3 7.2 01/06/2006 01:20:00 10.4 0.9 13 7.2 10.2 0.9 12.6 8 19 5 17 305 30.7 2.3 34.9 8.2 01/06/2006 01:30:00 10.1 1.1 13 7.2 9.9 1.1 13 7.2 19 5 15 305 20.6 8.7 34.6 -3.6 01/06/2006 01:40:00 10.3 1 12.6 7.2 10.2 1.1 13.3 7.6 20 5 14 305 18.4 1 21.6 7.2 01/06/2006 01:50:00 10.5 0.8 12.6 8 10.2 0.9 12.2 8 24 5 27 305 22.1 7 38.9 11.8 01/06/2006 02:00:00 10.7 1.3 14.1 6.8 10.3 1.3 13.7 7.6 28 5 25 305 35.5 4.2 38.9 10.5 01/06/2006 02:10:00 11.1 1.2 14.9 8 10.9 1.2 14.5 8.4 31 6 40 305 35 3.2 39.3 2.7 01/06/2006 02:20:00 12.1 1.2 15.6 9.1 11.8 1.3 15.6 8 33 6 27 305 35.1 2.9 40.3 11.3 01/06/2006 02:30:00 12.6 1.1 15.3 9.5 12.4 1.1 15.3 9.5 34 5 37 305 39 3.8 46.3 23.4 01/06/2006 02:40:00 11.7 1.6 16.1 7.6 11.4 1.5 15.3 8 32 6 31 305 38.5 2.2 41.3 28.8 01/06/2006 02:50:00 11.7 1.3 14.5 8.4 11.4 1.2 14.1 8 33 6 26 305 33.5 8.7 41.3 17.9 01/06/2006 03:00:00 11.8 1.5 15.3 8.8 11.7 1.5 15.3 8.8 35 6 30 305 24.1 0.9 26.4 20.1 01/06/2006 03:10:00 12.2 1.3 15.6 9.5 12 1.4 15.6 9.5 33 6 30 305 25.5 0.4 27.6 24.6 01/06/2006 03:20:00 13 1.2 15.6 9.1 12.7 1.2 14.9 9.1 34 5 35 305 25.8 2 27.6 15.3 01/06/2006 03:30:00 12.3 1.5 15.6 9.1 12.2 1.5 15.6 8.4 35 6 29 305 27.6 0.8 30.4 25.5 01/06/2006 03:40:00 12.5 1.2 15.6 9.1 12.3 1.2 15.3 9.1 33 6 27 305 40.9 6.2 45.5 27 01/06/2006 03:50:00 12.7 1.2 16.1 9.9 12.3 1.2 15.6 9.1 32 5 30 305 39.3 15.3 47.7 -12.9 01/06/2006 04:00:00 12.6 1.3 15.6 9.5 12.3 1.3 15.6 8.8 32 5 33 305 -12.6 0 -12.1 -12.9 01/06/2006 04:10:00 11.7 1.1 15.6 9.1 11.6 1.2 16.4 8.4 34 5 40 305 -5.2 14 23.1 -12.7 01/06/2006 04:20:00 11.8 1.2 14.9 8.8 11.7 1.3 15.3 8.8 34 6 41 305 24.7 3.2 30.7 11.3 01/06/2006 04:30:00 12.6 1.5 16.1 9.5 12.4 1.5 15.6 8.8 35 6 37 305 28.5 0.5 29.5 27.3 01/06/2006 04:40:00 12.4 1.3 14.9 9.1 12.1 1.5 15.6 8.8 37 6 39 305 28.7 0.2 29.5 27.9 01/06/2006 04:50:00 12.2 1.3 14.9 8.4 12 1.4 14.9 8.4 38 6 46 305 28.7 0.1 29.5 28.2 01/06/2006 05:00:00 11.9 1.4 15.6 8.4 11.7 1.4 15.3 8.4 37 7 29 305 29.1 0.2 29.8 27.9 01/06/2006 05:10:00 13.1 1.4 17.2 9.5 12.7 1.4 16.8 9.1 36 6 40 305 28.9 0.5 30.4 24.6 01/06/2006 05:20:00 12.3 1.7 16.4 8 12.2 1.6 16.4 8 41 6 44 305 31.4 4.7 43.1 21.6 01/06/2006 05:30:00 11.9 1.6 16.1 8 11.7 1.6 16.4 8.4 39 6 34 305 46.5 2.9 51 31.7 01/06/2006 05:40:00 11.4 1.7 16.4 8 11.3 1.8 16.1 8.4 37 8 35 305 47 0.2 47.7 44.8 01/06/2006 05:50:00 13.3 1.6 16.4 8 13.1 1.5 16.8 8.8 34 6 32 305 47.8 1.5 49.9 32 01/06/2006 06:00:00 11.1 1.1 14.9 8.8 10.8 1.1 14.1 7.6 38 7 27 305 49.1 0.3 49.9 46.3 01/06/2006 06:10:00 12.1 1.5 15.6 8.8 12 1.5 15.6 8.4 37 6 29 305 49.1 0.1 49.9 48.1 01/06/2006 06:20:00 12.1 1.6 16.4 8.8 11.8 1.5 15.6 8.4 38 6 40 305 48.5 1.1 49.9 30.7 01/06/2006 06:30:00 11.9 1.5 15.3 8.4 11.8 1.5 15.6 8.4 38 7 44 305 48.8 0 49.5 48.4 01/06/2006 06:40:00 10.5 1.3 14.5 7.6 10.5 1.3 14.5 7.2 42 6 32 305 48.6 0.5 49.5 46.3 01/06/2006 06:50:00 11.1 1.5 14.5 7.6 11 1.5 14.9 7.6 45 6 41 305 47.7 0.9 48.8 36.9 01/06/2006 07:00:00 12 1.7 15.3 7.6 11.9 1.6 14.9 8 42 8 26 305 46.6 0.5 48.1 44.1 01/06/2006 07:10:00 11.1 1.2 14.1 7.6 11 1.2 14.1 7.6 43 7 42 305 45.9 0.6 47 36.9 01/06/2006 07:20:00 12.7 1.3 15.6 9.1 12.6 1.3 15.6 9.1 44 7 38 305 45.6 0.7 47.3 42.4 01/06/2006 07:30:00 12.1 1.2 15.6 8.8 12 1.2 15.3 8.4 42 5 39 305 45.2 1.5 47.3 35.9 01/06/2006 07:40:00 11 1 13.3 8.4 10.9 1 13.7 8.8 39 6 37 305 46.1 1.2 47.3 32.3 01/06/2006 07:50:00 10 1.2 15.3 7.6 10 1.2 15.3 8 43 7 56 305 44.9 1.2 47 38.6 01/06/2006 08:00:00 10.9 1.5 14.5 7.6 10.8 1.5 14.9 7.2 44 6 42 305 42.5 4.7 46.3 30.1 01/06/2006 08:10:00 10.7 1.3 14.1 7.6 10.5 1.3 14.1 7.6 44 8 49 305 38.7 5.4 42 4.9 01/06/2006 08:20:00 11.9 1.2 14.5 8.8 11.7 1.3 14.5 8.4 44 7 40 305 41 0.1 41.7 40 01/06/2006 08:30:00 10.5 1.2 13.3 7.2 10.4 1.2 13.3 7.2 41 6 37 305 40.7 0.3 41.7 39.3 01/06/2006 08:40:00 9.8 0.9 11.8 7.2 9.6 1 11.8 6.8 50 7 63 305 40.8 0.3 42 39.6 01/06/2006 08:50:00 9.8 1.2 12.6 7.2 9.7 1.3 13 6.8 49 6 50 305 40.5 1.1 41.3 26.7 01/06/2006 09:00:00 10.5 1.7 14.5 7.2 10.4 1.7 14.1 6.5 49 7 42 305 40.9 0.3 42 40 01/06/2006 09:10:00 11.3 1.3 14.5 8 11.1 1.4 14.5 8.4 50 6 44 305 40.1 0.9 41.3 26.7 01/06/2006 09:20:00 11.3 1 13.7 8.8 11.4 1.1 13.7 8.4 51 5 48 305 40.1 2 42 30.7 01/06/2006 09:30:00 10.1 1.1 13 7.6 10 1.2 13 7.6 49 5 45 305 39.5 2.2 42.4 31 01/06/2006 09:40:00 9.2 1.3 12.2 6.5 9.1 1.3 12.2 6.5 51 6 50 305 34.8 4.2 42 26.7 01/06/2006 09:50:00 10.2 1 12.6 7.2 10.2 1.1 13.3 7.2 48 6 40 305 41.2 5.6 45.5 27.9 01/06/2006 10:00:00 10.4 1.1 13.3 7.2 10.4 1.1 13.3 7.2 45 6 44 305 38.4 6.2 46.3 28.5 01/06/2006 10:10:00 9.5 0.9 11.5 7.2 9.3 1 11.5 6.8 44 5 46 305 35.2 6.7 46.6 27.9 01/06/2006 10:20:00 8.9 0.9 10.7 6.5 8.8 1 11.1 6.5 44 5 43 305 43.2 2 45.2 23.7 01/06/2006 10:30:00 10.1 1.3 13.3 7.2 10.1 1.3 13.3 6.5 47 8 50 305 43.8 1.2 45.2 25.8 01/06/2006 10:40:00 10.1 1.2 12.6 7.2 10.1 1.3 13 6.8 46 6 44 305 43.1 0.8 44.5 34.6 01/06/2006 10:50:00 9 1.1 12.2 6.1 8.9 1.1 11.5 6.1 45 7 47 305 43.3 0.6 44.8 42 01/06/2006 11:00:00 9 1 11.1 6.1 9 1 11.5 5.7 48 5 45 305 47.3 4.7 52.9 21 01/06/2006 11:10:00 8.9 0.8 11.1 6.8 8.8 0.9 11.5 6.5 49 6 52 305 51 2.6 52.9 43.1 01/06/2006 11:20:00 9 1.1 11.8 6.5 8.9 1.1 11.8 6.5 44 6 32 305 50.8 2.4 52.9 43.1 01/06/2006 11:30:00 9 0.8 11.5 6.8 8.9 0.8 11.1 6.8 39 6 40 305 50.4 2.4 52.9 40 01/06/2006 11:40:00 9.1 0.9 11.8 6.5 8.9 0.9 11.5 6.5 37 6 43 305 49.6 2.9 52.9 35.3 01/06/2006 11:50:00 8.8 1.2 11.1 6.1 8.6 1.2 11.1 5.7 34 5 30 305 51.4 1.7 52.9 40.6 01/06/2006 12:00:00 8 1 9.9 5.7 8 1 10.3 5.7 38 6 48 305 49.3 1.5 50.6 40.6 01/06/2006 12:10:00 7.8 1.1 10.7 5.3 7.8 1.2 10.3 4.9 41 6 50 305 50.1 1.2 51.8 45.2 01/06/2006 12:20:00 9.2 1 11.8 7.2 9.2 1 11.8 6.5 44 6 38 305 50 0.3 51 46.6 01/06/2006 12:30:00 9.1 0.9 11.5 6.8 9 0.9 11.1 6.5 45 6 48 305 49.8 0 50.6 49.2 01/06/2006 12:40:00 9.4 1 11.8 7.2 9.4 1 12.2 7.2 43 7 46 305 49.5 0.3 50.3 48.4 01/06/2006 12:50:00 9.4 1 11.8 6.8 9.4 1.1 12.2 6.8 42 6 35 305 49.1 1.6 49.9 39.3 01/06/2006 13:00:00 10 1 12.2 7.6 9.9 1 12.2 7.2 43 6 42 305 49.5 0 49.9 48.8 01/06/2006 13:10:00 9.2 1 11.5 6.8 9.1 1.1 11.5 6.8 44 6 48 305 48.8 0.6 49.9 38.6 01/06/2006 13:20:00 8.6 1.1 11.5 6.1 8.6 1.2 12.2 6.1 42 7 54 305 48.9 1 49.9 38.6 01/06/2006 13:30:00 9.6 1 12.6 7.2 9.5 1 12.6 6.5 44 6 44 305 48 0.8 48.8 41.7 01/06/2006 13:40:00 9.6 1.5 13.3 6.5 9.5 1.5 14.1 6.1 42 6 48 305 44.8 1.7 48.4 31 01/06/2006 13:50:00 9.7 0.9 12.2 7.6 9.6 1 13 7.6 41 6 44 305 40.6 4 45.2 34.9 01/06/2006 14:00:00 9.6 1 12.2 6.8 9.5 1 12.2 6.8 39 6 38 305 34.9 1.9 37.6 27 01/06/2006 14:10:00 9.5 1.1 12.2 6.5 9.4 1.2 12.6 6.5 43 6 46 305 34.8 2.6 40.6 27.9 01/06/2006 14:20:00 9.8 0.9 12.6 7.6 9.7 1 12.2 7.6 47 6 51 305 39.4 0.7 41 36.6 01/06/2006 14:30:00 9.6 0.9 12.2 7.6 9.5 1 12.6 6.8 46 6 45 305 38.3 1.8 40 29.5 01/06/2006 14:40:00 9.6 1 12.6 7.2 9.6 1 12.2 6.8 45 6 47 305 44.7 3.2 47.3 36.2 01/06/2006 14:50:00 9.2 0.9 11.8 6.8 9 0.9 11.5 6.5 43 6 32 305 44.6 3.4 47.7 33.6 01/06/2006 15:00:00 8.9 1 12.2 6.5 8.8 1 11.5 6.5 40 6 39 305 38 2.3 44.1 26.1 01/06/2006 15:10:00 9.1 1 11.8 6.8 9 1.1 11.5 6.1 38 6 40 305 37.5 0.4 38.3 35.3 01/06/2006 15:20:00 9.6 0.9 11.8 6.8 9.5 1 11.8 7.2 36 5 42 305 37.2 0.6 38.6 35.3 01/06/2006 15:30:00 9.4 1 11.5 6.8 9.4 1 11.8 7.2 37 6 37 305 35.8 0.8 37.9 27.6 01/06/2006 15:40:00 9.4 0.9 11.5 6.8 9.4 0.9 11.5 6.5 39 5 38 305 35.7 0.5 36.9 34.3 01/06/2006 15:50:00 8.6 0.6 10.3 7.2 8.6 0.6 9.9 6.8 39 6 45 305 36.1 0.8 38.9 32 01/06/2006 16:00:00 8.4 0.7 9.9 6.8 8.4 0.7 10.3 6.5 39 4 39 305 31.9 4.7 43.1 9.7 01/06/2006 16:10:00 8.6 1.1 11.8 6.1 8.5 1.1 11.8 6.5 36 6 23 305 43.6 0.8 44.8 37.6 01/06/2006 16:20:00 8.8 0.9 11.1 6.8 8.7 1 11.1 6.1 37 5 41 305 43.2 0.6 44.5 37.6 01/06/2006 16:30:00 9.4 1 11.8 7.2 9.3 1 11.8 7.2 34 4 39 305 36.1 5.9 43.8 29.5 01/06/2006 16:40:00 9.2 0.9 11.5 7.2 9.2 1 11.8 6.8 34 5 36 305 29.4 0.7 31.7 25.8 01/06/2006 16:50:00 9.9 0.9 11.8 7.6 9.8 0.8 11.8 7.6 33 5 33 305 29.5 2.3 34.3 13.2 01/06/2006 17:00:00 8.8 0.7 10.7 7.2 8.8 0.8 10.7 6.8 33 5 35 305 32.2 3.2 37.6 27.6 01/06/2006 17:10:00 8.2 0.6 9.9 6.5 8.2 0.6 9.5 6.5 36 5 35 305 41.3 5 48.4 36.6 01/06/2006 17:20:00 8.6 0.5 9.9 6.8 8.5 0.6 9.9 6.8 37 4 35 305 46.9 0.6 47.7 38.6 01/06/2006 17:30:00 8.7 0.6 10.7 6.8 8.8 0.6 11.1 7.2 39 5 36 305 46.3 0.7 47.7 44.8 01/06/2006 17:40:00 9.8 0.9 12.2 8 9.8 1 12.2 8 41 5 37 305 45.6 1.1 47 36.6 01/06/2006 17:50:00 10.3 0.9 12.2 8 10.2 1 12.6 8 43 4 47 305 45.5 1.6 47.3 35.9 01/06/2006 18:00:00 10.2 0.8 12.2 8 10.2 0.8 12.6 8.4 43 4 45 305 45.5 0.6 46.6 44.5 01/06/2006 18:10:00 10.5 0.9 13 8 10.5 0.9 13 8 41 5 50 305 45.5 1.7 46.6 35.9 01/06/2006 18:20:00 10.9 1 13 8.4 10.8 1.1 13.3 8.4 41 5 41 305 45.5 1.7 46.6 34.9 01/06/2006 18:30:00 10.8 0.9 13.3 8.8 10.8 0.9 14.1 8 38 5 45 305 45.5 0.2 46.3 44.5 01/06/2006 18:40:00 11.8 1 14.1 8.4 11.7 1 14.5 8.4 41 5 43 305 45.6 0.7 46.3 39.6 01/06/2006 18:50:00 12.2 0.8 13.7 9.9 12 0.8 14.1 9.5 40 4 40 305 43.9 3.1 46.3 26.1 01/06/2006 19:00:00 13.3 1.2 15.6 9.5 13.3 1.3 15.6 9.5 42 4 41 305 45.8 1.1 47.3 34.9 01/06/2006 19:10:00 13.2 1.2 15.3 9.9 13.1 1.2 15.3 9.5 42 4 43 305 45.7 0.3 47 43.1 01/06/2006 19:20:00 13.2 1 14.9 9.9 13 1.1 15.3 9.5 42 5 43 305 42.5 3.7 46.3 31.7 01/06/2006 19:30:00 12.4 1.1 14.9 9.5 12.4 1.2 14.9 9.5 42 4 40 305 38 0.7 39.6 36.6 01/06/2006 19:40:00 12.4 1.1 15.3 9.5 12.3 1.1 14.5 9.5 45 5 42 305 35.7 2.6 39.6 24 01/06/2006 19:50:00 12.7 1.2 15.3 9.5 12.7 1.2 14.9 9.1 43 5 35 305 37.2 3.2 39.3 21.9 01/06/2006 20:00:00 12.9 1.2 15.3 9.5 12.7 1.3 15.3 9.5 42 5 41 305 34.5 4.2 37.9 21.9 01/06/2006 20:10:00 13.5 1.3 15.6 9.9 13.3 1.2 16.1 9.9 44 5 43 305 37.2 2.9 39.3 20.4 01/06/2006 20:20:00 13.3 1.1 16.1 10.7 13.3 1.2 16.1 10.7 48 4 47 305 38.5 0.6 40 36.2 01/06/2006 20:30:00 13.1 1.1 15.3 10.3 13.1 1.2 15.3 9.5 47 5 48 305 31.7 5.2 39.3 20.1 01/06/2006 20:40:00 13.2 1 15.6 10.3 13 1 14.9 10.3 47 4 41 305 32.7 2.8 41.3 24.6 01/06/2006 20:50:00 12.6 1.1 14.9 9.1 12.6 1.2 14.5 8.8 47 4 48 305 34.1 1 35.3 25.2 01/06/2006 21:00:00 11.3 1.1 13.7 8 11.3 1.2 14.1 8.4 44 5 50 305 31 2.9 34.3 18.7 01/06/2006 21:10:00 11.2 1.1 13.3 8 11.1 1.2 13.7 8 45 5 44 305 28.6 2 34.9 13.2 01/06/2006 21:20:00 10.2 1.2 12.6 6.8 10 1.2 13 6.8 42 6 44 305 39.4 3.4 48.1 33 01/06/2006 21:30:00 9.3 1.2 11.8 6.8 9.1 1.2 11.8 6.5 40 6 47 305 44.6 2.9 47.7 34.9 01/06/2006 21:40:00 9 1.1 11.1 6.5 8.9 1.1 11.1 6.1 41 6 42 305 35.3 0.5 37.2 33 01/06/2006 21:50:00 9.4 1 11.8 7.2 9.2 1 11.5 6.5 38 5 37 305 34 2.2 37.6 26.1 01/06/2006 22:00:00 9.8 0.9 11.8 7.2 9.7 0.9 11.5 7.2 37 5 33 305 35.1 2.6 37.9 20.7 01/06/2006 22:10:00 9.1 1 11.1 6.5 8.8 1 11.1 6.5 37 6 43 305 34.7 1.4 36.9 17.9 01/06/2006 22:20:00 9.8 0.9 11.5 7.2 9.7 0.9 11.5 6.8 38 5 38 305 35.1 0.5 36.6 31 01/06/2006 22:30:00 9.7 1.3 12.6 6.5 9.5 1.3 12.6 6.1 37 5 37 305 43 4.7 47.7 33.3 01/06/2006 22:40:00 10.3 1 12.6 7.6 10.2 1.1 12.6 6.8 40 5 27 305 43.8 2.1 46.6 30.7 01/06/2006 22:50:00 10 0.9 11.8 7.6 9.8 0.9 11.5 7.2 40 5 35 305 45.4 1.7 47 35.9 01/06/2006 23:00:00 10.1 1 12.6 7.2 10 1.1 12.2 7.6 41 5 42 305 44.1 2.3 47 33.9 01/06/2006 23:10:00 10.3 0.8 11.8 7.6 10.1 0.9 11.8 7.2 40 5 39 305 44.9 2 47.3 33.3 01/06/2006 23:20:00 9.5 1 11.8 7.2 9.4 1.1 11.5 6.8 37 5 34 305 42.3 4.4 47.3 27.6 01/06/2006 23:30:00 9.3 0.6 11.1 7.6 9.3 0.7 10.7 6.5 37 4 36 305 33.9 5.9 44.5 15.3 01/06/2006 23:40:00 8.9 1 11.1 6.1 8.7 1 11.1 6.5 35 5 37 305 44.1 2.1 47.3 37.6 01/06/2006 23:50:00 9.7 1.1 11.8 6.5 9.6 1.1 11.8 5.7 37 6 33 305 47 0.9 48.4 41.7 01/07/2006 00:00:00 9.7 1 12.2 7.6 9.6 1.1 12.2 7.2 39 5 40 305 44.3 4.4 48.4 30.7 01/07/2006 00:10:00 11.4 1.2 13.7 8.4 11.3 1.3 14.1 7.6 36 5 35 305 45.6 4.2 49.5 33.3 01/07/2006 00:20:00 11.5 0.9 13.3 8.8 11.3 1 13.3 9.1 40 5 37 305 46.3 2.3 49.5 38.9 01/07/2006 00:30:00 11.1 0.9 13.3 8.8 10.8 1 13.3 8.4 38 5 37 305 46.8 2.1 49.2 38.9 01/07/2006 00:40:00 11.7 1.1 14.1 9.1 11.7 1 14.5 9.1 41 6 31 305 48.2 1.7 49.9 39.3 01/07/2006 00:50:00 11.7 1.3 14.5 8.8 11.6 1.4 14.9 8.4 45 5 48 305 47.1 1.8 49.9 37.9 01/07/2006 01:00:00 12 1 14.1 9.1 11.8 1 14.5 9.1 43 5 48 305 44.1 4 48.4 33.3 01/07/2006 01:10:00 10.5 1.2 13 8.4 10.3 1.2 13 7.6 43 6 40 305 30.6 3.5 35.9 3.2 01/07/2006 01:20:00 10.2 1.1 13 7.6 10 1.1 13.3 6.8 43 6 44 305 30.4 2.8 33.3 3.4 01/07/2006 01:30:00 9.5 1 11.8 7.2 9.3 1 11.8 6.5 43 6 41 305 33.9 2.6 35.9 10.5 01/07/2006 01:40:00 9 1.1 11.5 6.5 8.6 1.1 11.1 6.1 41 7 39 305 36.2 3.7 43.1 15.6 01/07/2006 01:50:00 9.4 0.9 11.1 6.5 9.3 1 11.5 6.1 39 6 43 305 39.2 5.4 46.3 19.6 01/07/2006 02:00:00 8.6 1 11.5 6.5 8.5 1.1 11.8 6.5 41 6 37 305 45.2 2.6 49.9 35.3 01/07/2006 02:10:00 9.6 0.8 11.5 7.2 9.4 0.9 11.5 6.8 41 6 37 305 45.7 2.2 48.8 37.9 01/07/2006 02:20:00 9.8 1.1 12.2 7.2 9.8 1.2 12.2 7.2 39 5 35 305 46.1 1.9 49.2 38.6 01/07/2006 02:30:00 9.8 1.1 12.6 7.6 9.7 1.1 12.6 7.2 37 5 36 305 45.5 2.1 50.6 39.3 01/07/2006 02:40:00 10.3 1.1 13 7.6 10.1 1.2 12.6 6.8 37 5 36 305 46.3 0.1 47 45.5 01/07/2006 02:50:00 9.8 1.1 12.2 6.8 9.7 1.1 12.2 6.8 37 5 32 305 45.9 1.2 47 40.6 01/07/2006 03:00:00 9.6 1.1 12.2 7.2 9.5 1.2 12.2 6.5 39 6 37 305 46.2 1.4 47.3 36.2 01/07/2006 03:10:00 10.1 1 13 7.2 10 1 13 7.6 36 5 29 305 46 0.2 46.6 44.8 01/07/2006 03:20:00 10.6 1 13 7.6 10.5 1 12.6 7.6 36 5 36 305 44.5 0.3 45.5 43.4 01/07/2006 03:30:00 9.9 1.2 12.6 6.8 9.8 1.2 12.6 7.2 38 5 39 305 44.2 1.4 46.6 33.9 01/07/2006 03:40:00 9.8 1.2 12.2 7.2 9.6 1.2 12.6 6.8 38 5 40 305 43.6 1 45.5 39.6 01/07/2006 03:50:00 9.9 1 12.2 7.2 9.8 1 12.2 6.5 39 5 42 305 43 0.8 44.1 36.2 01/07/2006 04:00:00 9.4 1.1 12.2 6.8 9.2 1.1 11.8 6.8 38 6 34 305 43.9 0.4 44.8 43.1 01/07/2006 04:10:00 10.3 1 12.6 7.6 10.2 1.1 12.6 7.6 37 5 40 305 44.5 1.5 48.4 42.4 01/07/2006 04:20:00 10.1 1.1 12.2 6.8 10 1.2 12.6 6.5 37 5 38 305 48.2 0.6 48.8 43.8 01/07/2006 04:30:00 9.9 0.8 12.2 7.6 9.8 0.8 11.8 7.2 38 5 31 305 48.4 0.7 49.2 39.6 01/07/2006 04:40:00 10.2 1.1 13.3 7.6 10.1 1.2 13.3 7.6 37 5 43 305 47.1 1 49.2 45.5 01/07/2006 04:50:00 11.5 1.2 14.1 7.6 11.4 1.2 14.1 7.6 42 5 35 305 48.3 1.4 49.9 40.3 01/07/2006 05:00:00 11.3 1.1 13.7 8.4 11.1 1.1 13.7 8.4 41 5 39 305 48.4 0.2 49.5 47.3 01/07/2006 05:10:00 11.5 0.9 13.7 9.5 11.3 1 13.7 8.4 41 5 39 305 47.2 1.2 48.8 40 01/07/2006 05:20:00 10.9 0.9 13 8.8 10.8 1 13.3 8.4 39 5 37 305 49.6 2.7 52.9 44.5 01/07/2006 05:30:00 11 0.7 12.6 8.8 10.9 0.8 12.6 8.4 36 4 32 305 44.5 1.7 50.6 37.9 01/07/2006 05:40:00 10.6 1 13 8.4 10.6 1.1 13.3 8 38 5 44 305 43.3 1 45.2 37.6 01/07/2006 05:50:00 10.2 0.8 12.2 8 10.1 0.9 12.2 8 38 5 40 305 44.6 0.8 45.9 40.3 01/07/2006 06:00:00 10 0.8 11.8 8 9.9 0.8 12.2 8 36 5 32 305 44.5 0.4 45.5 42 01/07/2006 06:10:00 10.6 1 13.3 7.6 10.6 1.1 13.3 7.6 36 4 36 305 43.2 2 45.9 40 01/07/2006 06:20:00 11.3 0.9 13.3 9.1 11.2 1 13.3 8.4 41 5 49 305 43.5 2.6 47 33.3 01/07/2006 06:30:00 11 1.3 14.1 7.6 11 1.4 13.7 7.6 40 5 43 305 45.2 0.3 46.3 43.4 01/07/2006 06:40:00 10.9 0.8 12.6 8.8 10.9 0.9 13 8.4 42 5 39 305 45.2 0.4 46.6 43.8 01/07/2006 06:50:00 12 0.7 13.7 9.9 12 0.8 14.1 9.1 40 4 41 305 45.1 0.2 46.3 44.5 01/07/2006 07:00:00 11.6 0.9 13.7 9.1 11.5 1.1 14.1 9.1 43 4 48 305 45.1 1.1 46.6 30.7 01/07/2006 07:10:00 11.1 1.2 13.3 8.4 11 1.2 13.7 8 42 5 41 305 44.6 0.3 45.5 43.4 01/07/2006 07:20:00 10.4 0.8 12.6 8 10.3 0.8 12.6 8.4 41 5 43 305 44.2 0.5 45.2 38.9 01/07/2006 07:30:00 10.4 1 12.6 7.2 10.3 1 12.6 7.6 41 5 42 305 44.2 0.4 45.2 43.1 01/07/2006 07:40:00 10.2 0.8 11.8 8 10.1 0.9 12.2 7.6 44 5 43 305 44.1 1.8 45.9 30.4 01/07/2006 07:50:00 9.9 0.9 12.2 6.8 9.8 0.9 11.8 6.8 45 5 48 305 43.8 0.4 45.2 42.4 01/07/2006 08:00:00 9.1 1 11.8 6.8 9 1 11.8 6.5 44 5 41 305 44.1 1.3 45.9 30.4 01/07/2006 08:10:00 9.1 0.9 11.1 7.2 9 0.9 11.5 7.2 42 5 49 305 41.7 5.4 45.9 31 01/07/2006 08:20:00 8.8 1 11.1 6.1 8.7 1 11.5 6.1 40 6 41 305 45 0.4 45.9 43.8 01/07/2006 08:30:00 9.6 1.2 12.2 6.1 9.5 1.3 12.6 6.1 35 7 19 305 44.1 1.1 45.5 31 01/07/2006 08:40:00 9.5 1 11.8 7.2 9.4 1 11.8 6.8 40 6 40 305 43.9 0.4 44.8 42.7 01/07/2006 08:50:00 9.9 1 12.2 7.6 9.8 1 12.2 7.6 39 6 38 305 43.8 0.3 44.8 42.7 01/07/2006 09:00:00 10.1 1.2 12.6 7.2 10 1.1 12.6 7.6 35 5 32 305 43.6 0.9 44.5 32 01/07/2006 09:10:00 9.6 1.2 12.6 6.8 9.5 1.2 12.6 6.8 35 6 29 305 43.8 0.4 45.2 42.4 01/07/2006 09:20:00 10.4 1.1 12.2 8 10.2 1.1 12.6 7.6 35 5 30 305 43.9 0.4 45.2 42.4 01/07/2006 09:30:00 10.2 1.1 12.6 7.2 10.1 1 12.2 6.8 38 5 36 305 43.9 0.3 44.8 42.4 01/07/2006 09:40:00 10.1 1.2 13 6.5 9.8 1.2 13 6.5 40 6 36 305 43.9 0.5 45.2 42.4 01/07/2006 09:50:00 8.7 1 12.6 5.7 8.6 1 11.8 6.5 38 7 41 305 43.5 0.4 44.5 42.4 01/07/2006 10:00:00 8.8 1 11.1 6.1 8.7 1 10.7 6.1 40 6 45 305 43.2 0.4 44.1 39.3 01/07/2006 10:10:00 8.5 0.9 10.7 6.1 8.2 1 10.3 5.7 41 6 35 305 43.2 0.5 44.5 41.3 01/07/2006 10:20:00 9.4 1.2 12.2 6.8 9.2 1.3 12.2 5.7 38 7 35 305 43.4 0.8 45.2 38.9 01/07/2006 10:30:00 9.1 1.2 11.8 6.1 8.9 1.2 11.5 6.1 38 6 52 305 44.5 0.6 45.5 42.7 01/07/2006 10:40:00 8.6 1.3 11.8 5.3 8.6 1.3 12.2 5.3 42 7 41 305 44.7 0.5 46.3 43.1 01/07/2006 10:50:00 9.5 1.1 11.8 7.2 9.3 1.1 11.8 6.1 40 6 39 305 43.3 1.6 44.5 36.2 01/07/2006 11:00:00 10.5 1.2 13 7.6 10.3 1.2 13 7.6 41 7 34 305 43.8 0.3 44.8 42.7 01/07/2006 11:10:00 8.6 1.4 12.6 6.1 8.4 1.5 12.2 5.3 43 7 35 305 43.2 0.7 44.8 40.6 01/07/2006 11:20:00 8.4 0.9 10.7 6.1 8.2 1 11.1 4.9 42 6 47 305 43.5 0.8 45.2 36.9 01/07/2006 11:30:00 9.5 1 11.8 6.5 9.2 1.1 12.2 6.8 41 8 39 305 44 0.5 45.2 42 01/07/2006 11:40:00 10 1.4 13.3 7.2 9.8 1.4 13.3 6.8 42 6 48 305 43.6 0.5 44.8 41.3 01/07/2006 11:50:00 9.8 1.1 13 6.8 9.7 1.3 13 6.8 43 7 57 305 43.9 0.4 44.5 42 01/07/2006 12:00:00 10.3 1 13.3 7.6 10.1 1 12.6 8 36 7 40 305 43.7 0.4 44.5 41.7 01/07/2006 12:10:00 10.7 1.1 13 7.6 10.6 1.1 13.3 7.2 35 5 35 305 43.2 0.5 44.1 41 01/07/2006 12:20:00 10.1 1.1 12.6 7.2 9.9 1.1 13 7.2 34 5 26 305 43 1.2 44.5 30.1 01/07/2006 12:30:00 10.1 1.3 13.3 6.8 9.9 1.2 13.7 6.5 35 6 37 305 43.2 1.1 44.8 30.7 01/07/2006 12:40:00 10.5 1.1 13 6.8 10.3 1.1 13 7.2 33 5 37 305 44 0.4 45.2 42.7 01/07/2006 12:50:00 9.6 1.1 12.2 6.8 9.5 1.1 12.6 6.1 35 6 36 305 40.6 3.7 44.5 33 01/07/2006 13:00:00 10.2 0.9 12.6 8 10.1 1 12.6 6.8 35 6 30 305 47.2 2 49.5 35.9 01/07/2006 13:10:00 9.5 0.9 12.2 7.2 9.3 1 11.8 6.8 36 5 33 305 47.5 0.6 49.2 44.8 01/07/2006 13:20:00 9 1.1 11.8 6.1 8.9 1.2 11.8 6.1 36 7 36 305 48.9 1.4 51.8 43.1 01/07/2006 13:30:00 9.1 1.1 12.2 6.5 9 1.2 11.8 6.1 36 6 41 305 48.3 4.5 52.9 25.2 01/07/2006 13:40:00 10.1 0.9 12.2 8 10 1 12.6 7.2 37 5 45 305 51.9 0.8 52.9 43.8 01/07/2006 13:50:00 9.6 1.1 11.8 6.8 9.4 1.1 11.8 6.5 36 6 31 305 51.5 1.5 52.9 43.1 01/07/2006 14:00:00 9.5 1.1 12.2 6.8 9.4 1.1 12.2 7.2 35 6 35 305 52 0.3 52.9 48.4 01/07/2006 14:10:00 9.5 1.1 12.2 7.2 9.3 1.1 12.6 6.8 30 6 33 305 51.6 0.7 52.9 43.8 01/07/2006 14:20:00 8.9 1 11.5 6.5 8.8 1 11.1 6.5 32 5 36 305 50.9 1 52.9 41.3 01/07/2006 14:30:00 9.7 1 11.8 6.5 9.4 1.1 11.8 6.5 31 6 29 305 50.1 1.9 52.1 40.3 01/07/2006 14:40:00 9.3 1.1 12.2 6.5 9.1 1.2 11.8 6.5 26 6 29 305 49.7 1.7 52.5 38.9 01/07/2006 14:50:00 10.1 1 13 8 10 1 13 7.6 28 6 35 305 49.9 2.1 51.4 37.9 01/07/2006 15:00:00 9.9 1.2 13 6.8 9.7 1.3 12.6 7.2 29 5 30 305 49.2 1.8 50.6 37.9 01/07/2006 15:10:00 10.2 1 12.6 7.6 10.1 1.1 13 7.6 29 5 28 305 48.9 1.4 50.3 37.9 01/07/2006 15:20:00 10.2 1.2 13 7.6 10 1.1 13 7.2 33 6 22 305 48.8 1.2 51 36.9 01/07/2006 15:30:00 10 1.3 13.3 6.8 9.9 1.3 13.3 6.8 34 6 37 305 49.1 0.5 49.9 47 01/07/2006 15:40:00 10.3 1.1 13.3 8 10.2 1.2 12.6 7.2 33 6 35 305 49.4 0.3 50.6 48.1 01/07/2006 15:50:00 10.5 1.2 14.1 7.2 10.4 1.2 13.7 6.8 34 8 43 305 49.6 1.1 50.6 36.6 01/07/2006 16:00:00 9.9 1.1 13.7 7.6 9.8 1.1 13 7.2 37 6 30 305 49.3 1 50.3 37.2 01/07/2006 16:10:00 9.8 1.1 13 7.6 9.6 1.1 13 7.2 33 6 29 305 50 0.3 51.4 48.8 01/07/2006 16:20:00 10.4 1 12.6 7.6 10.2 1 12.6 7.6 31 5 43 305 49.7 1.8 51.8 39.3 01/07/2006 16:30:00 10.7 0.9 13.3 8 10.6 1 13.3 8 35 5 33 305 43.4 3.8 48.4 23.1 01/07/2006 16:40:00 10 1 13 7.6 9.9 1 13 8 35 5 41 305 47.7 3.7 51 37.2 01/07/2006 16:50:00 11.4 1.1 13.7 7.6 11.3 1.1 13.7 8.4 35 5 35 305 50.4 0.3 51.4 48.4 01/07/2006 17:00:00 11.3 1 13.7 8.8 11.3 1 14.1 9.1 37 5 33 305 50.7 1.1 52.5 40 01/07/2006 17:10:00 10.3 1 12.6 8.4 10.2 1 12.6 8 38 5 34 305 49.8 0.5 52.5 48.8 01/07/2006 17:20:00 11 1.1 13.7 8 10.9 1.1 13.7 8 39 5 37 305 49.6 0.1 50.3 48.8 01/07/2006 17:30:00 11.2 1.4 14.5 8 11.1 1.3 14.5 8.4 39 6 37 305 49.8 0.1 50.6 49.2 01/07/2006 17:40:00 11.6 1.3 14.9 8.4 11.4 1.2 14.5 8.4 39 5 33 305 52 0.9 52.9 49.9 01/07/2006 17:50:00 12.4 1.2 15.6 9.1 12.2 1.3 15.3 9.1 36 5 37 305 52.4 0.2 52.9 51.8 01/07/2006 18:00:00 12.8 1.2 16.4 9.5 12.6 1.2 16.1 9.1 36 5 46 305 51.4 0.2 52.1 50.6 01/07/2006 18:10:00 11.8 0.9 14.1 9.5 11.7 1 14.5 9.1 37 5 35 305 50.8 0.1 51.4 50.3 01/07/2006 18:20:00 12.3 1.1 14.9 9.5 12.1 1.2 14.9 9.1 37 5 36 305 50.5 0.2 51 49.5 01/07/2006 18:30:00 12.8 1 15.3 10.3 12.5 1 15.3 9.9 35 5 37 305 49.6 1.5 50.6 37.2 01/07/2006 18:40:00 13.3 1.2 16.4 10.7 13.1 1.2 16.4 10.3 38 5 33 305 49.9 0.2 51 48.8 01/07/2006 18:50:00 11.9 1 14.5 9.1 11.7 1 14.5 9.1 38 6 29 305 45.8 4.4 50.3 34.3 01/07/2006 19:00:00 13 0.9 15.6 10.7 12.8 1 15.6 10.3 38 5 35 305 48.9 0.7 51 46.6 01/07/2006 19:10:00 13.2 1.3 16.8 9.9 13.1 1.3 16.1 9.9 38 5 37 305 50.2 0.3 52.1 49.2 01/07/2006 19:20:00 12.9 1.5 16.8 9.9 12.8 1.5 16.4 9.5 36 6 36 305 50.3 0 51 49.9 01/07/2006 19:30:00 12.7 1 14.9 9.9 12.5 1 14.5 9.1 31 4 35 305 50.1 0 51 49.9 01/07/2006 19:40:00 12.3 1 14.1 9.9 12.1 1 14.1 9.5 33 5 35 305 50.3 0.1 51.4 49.9 01/07/2006 19:50:00 12.7 1 15.3 9.5 12.5 1 15.3 9.9 33 5 35 305 50.2 0 51 49.5 01/07/2006 20:00:00 12.3 1 14.5 9.1 12.1 1.1 14.1 8.8 32 4 33 305 50.1 0 51 49.5 01/07/2006 20:10:00 12.4 1.1 14.5 9.5 12.3 1.1 14.9 9.5 33 5 35 305 50.1 0 51 49.5 01/07/2006 20:20:00 13.6 1 15.6 11.1 13.4 1 15.6 10.3 37 5 32 305 50.2 0 51 49.9 01/07/2006 20:30:00 12.7 1 15.3 10.3 12.6 1.1 15.3 9.9 41 5 40 305 50.4 0 51 50.3 01/07/2006 20:40:00 12.5 1.3 14.9 8.4 12.3 1.3 15.3 8.4 39 6 33 305 50.4 0.5 51 47.3 01/07/2006 20:50:00 12.5 1.2 14.9 9.5 12.3 1.2 15.3 8.8 38 6 35 305 49.3 0.4 50.3 44.8 01/07/2006 21:00:00 13.4 1.1 15.6 10.3 13.3 1.3 15.6 9.9 41 5 38 305 49.7 1.1 51 37.2 01/07/2006 21:10:00 12.4 1.7 16.4 8.4 12.4 1.7 16.8 8.8 42 5 41 305 50.2 1 51.8 37.2 01/07/2006 21:20:00 11.7 1 14.5 9.1 11.6 1 14.1 8.8 39 5 47 305 51.2 0.3 52.1 49.9 01/07/2006 21:30:00 12.2 1.2 15.3 8.8 12.1 1.2 15.3 8.8 39 5 37 305 50.8 1.5 51.8 37.9 01/07/2006 21:40:00 12.4 1 15.3 9.5 12.2 1 15.3 9.1 38 6 40 305 51.8 0.3 52.9 51 01/07/2006 21:50:00 13.1 1.1 16.1 9.9 13.1 1.2 16.1 9.9 45 6 40 305 51.3 0.2 51.8 49.5 01/07/2006 22:00:00 13.6 1.2 16.8 9.9 13.5 1.3 16.4 9.1 46 5 39 305 51.5 0.2 52.5 49.5 01/07/2006 22:10:00 12.7 1.2 15.6 9.1 12.5 1.3 16.1 8.8 44 5 45 305 51.9 1.2 52.9 38.6 01/07/2006 22:20:00 10.9 1 13 8.4 10.8 1 13.3 8.4 41 6 46 305 50.9 1 51.8 37.9 01/07/2006 22:30:00 12.9 1.2 15.3 9.1 12.7 1.3 14.9 9.1 38 6 35 305 50.8 0.4 51.8 49.5 01/07/2006 22:40:00 11.6 1.1 13.7 9.1 11.3 1.2 14.5 8.8 44 5 48 305 50.6 0.4 51.8 47.3 01/07/2006 22:50:00 13.1 1.7 16.8 9.9 12.9 1.8 16.8 9.5 45 6 46 305 50.8 0.4 51.8 49.5 01/07/2006 23:00:00 13.1 1.1 15.6 10.3 13.1 1.2 15.6 10.3 46 5 45 305 50.7 0.2 51.4 49.9 01/07/2006 23:10:00 12.6 1 14.9 10.7 12.5 1 15.3 9.9 46 6 43 305 51.8 0.4 52.5 49.9 01/07/2006 23:20:00 12.5 1.2 14.9 9.1 12.4 1.2 15.3 8.8 45 5 44 305 51.9 0 52.5 51 01/07/2006 23:30:00 11.6 1 13.7 9.1 11.4 1 13.7 8.4 43 5 40 305 50 1.2 52.1 35.9 01/07/2006 23:40:00 13 1.1 16.1 10.3 12.8 1.2 15.6 9.9 40 5 36 305 48.2 1.3 49.9 45.5 01/07/2006 23:50:00 13.6 1.3 16.4 10.3 13.3 1.4 16.8 9.9 39 5 40 305 44.2 2.2 46.6 32 01/08/2006 00:00:00 14 1 16.1 11.8 13.7 1 16.1 11.5 38 5 41 305 43.3 1.2 45.9 40 01/08/2006 00:10:00 13.9 0.9 16.1 11.5 13.8 1 16.1 11.5 36 4 31 305 42.5 1.1 44.8 36.9 01/08/2006 00:20:00 14.2 1 16.4 11.1 14 1 16.1 10.7 35 4 36 305 42.5 0.3 43.1 41 01/08/2006 00:30:00 14.1 0.9 16.4 11.5 13.8 1 16.4 11.5 37 5 34 305 42.4 0.3 43.1 40.6 01/08/2006 00:40:00 12.6 1 14.9 9.5 12.4 1.1 14.9 9.9 37 5 35 305 42.5 1.1 43.4 38.3 01/08/2006 00:50:00 12.4 1 14.9 9.9 12.3 1.1 14.9 9.9 37 5 37 305 42.5 0.4 43.8 39.3 01/08/2006 01:00:00 13.6 0.9 15.6 10.7 13.5 1 16.1 10.3 38 5 39 305 42.7 0.3 43.4 41.3 01/08/2006 01:10:00 12.5 1.1 14.9 9.5 12.5 1.2 15.3 9.5 40 5 47 305 42.5 0.2 43.1 42 01/08/2006 01:20:00 13.3 1 16.1 10.7 13.3 1.1 16.4 10.7 41 5 45 305 42.3 0.1 43.1 40.3 01/08/2006 01:30:00 13.2 1.3 16.4 10.3 13 1.4 16.8 9.9 38 4 35 305 42.6 0.5 43.4 39.6 01/08/2006 01:40:00 13.3 1.1 16.1 10.7 13.1 1.1 15.3 10.3 35 5 36 305 42.5 0.2 43.1 40 01/08/2006 01:50:00 12.1 1.5 15.3 8.4 11.9 1.5 15.6 8.8 38 5 34 305 42.5 0.7 43.4 39.3 01/08/2006 02:00:00 10.8 1.3 14.1 7.2 10.6 1.3 14.1 7.2 34 6 36 305 43.1 0.8 44.8 40.3 01/08/2006 02:10:00 12.2 1.5 15.6 8.8 12 1.4 15.6 8 38 6 39 305 44 0.1 44.5 43.4 01/08/2006 02:20:00 11.4 1.2 14.1 8.4 11.3 1.2 14.1 7.6 35 6 29 305 43.9 0.4 44.5 42 01/08/2006 02:30:00 10.4 1.2 13 7.6 10.2 1.2 13 6.8 35 7 28 305 43.8 1.5 44.8 29.2 01/08/2006 02:40:00 11 1.3 14.5 8 10.6 1.2 14.1 8 31 6 39 305 43.3 0.4 44.5 40 01/08/2006 02:50:00 12.2 1.3 15.6 9.1 12.1 1.4 16.1 9.1 34 5 30 305 42.9 0.2 43.8 42 01/08/2006 03:00:00 11.2 2.2 15.6 6.8 11 2.2 16.1 6.5 38 6 41 305 43.2 1.6 44.5 27.9 01/08/2006 03:10:00 9.3 0.9 11.5 7.2 9.2 0.9 11.5 6.8 36 6 35 305 42 2.9 44.5 27.6 01/08/2006 03:20:00 10.4 1.2 13 7.2 10.3 1.2 13.3 7.6 31 6 23 305 42.5 1.8 44.1 27.3 01/08/2006 03:30:00 10.4 1.3 14.9 8 10.2 1.3 14.1 7.6 32 6 39 305 42.6 0.7 43.4 35.6 01/08/2006 03:40:00 10.5 1.2 12.6 7.6 10.3 1.2 12.6 7.2 35 6 30 305 42.4 2 44.1 26.4 01/08/2006 03:50:00 10.5 1 13.7 8 10.3 1 13.7 8 32 6 33 305 42.5 1.6 43.8 26.7 01/08/2006 04:00:00 11.3 1.4 14.5 8.4 11 1.3 14.5 8 36 6 31 305 42.7 1.3 43.4 27 01/08/2006 04:10:00 12.1 1.3 14.9 9.1 12 1.3 15.3 8.8 38 6 29 305 42.4 1.2 43.4 27.6 01/08/2006 04:20:00 12.1 1.3 15.3 8.8 11.9 1.4 15.6 8 33 6 33 305 41.8 0.4 42.7 39.3 01/08/2006 04:30:00 11 1.1 13.7 8.4 10.9 1.1 13.7 8.4 36 4 28 305 41.7 0.3 42.4 37.9 01/08/2006 04:40:00 11.5 1.1 14.1 9.1 11.5 1.2 14.1 8.4 37 6 42 305 43.5 2.5 46.6 26.1 01/08/2006 04:50:00 13.3 1.1 16.1 10.3 13.2 1.1 16.4 10.7 37 5 35 305 45.5 0.4 46.6 42.4 01/08/2006 05:00:00 12.2 1.1 14.9 8.8 12 1.1 14.5 8.8 36 5 35 305 45.4 0.6 46.6 42.4 01/08/2006 05:10:00 11.7 1 13.7 8 11.4 1.1 14.5 7.6 36 5 39 305 46.5 0.6 47.7 44.5 01/08/2006 05:20:00 11.5 1.1 14.5 8.4 11.3 1.1 14.1 8 33 6 30 305 47.2 0.5 47.7 43.1 01/08/2006 05:30:00 11.5 1.7 15.6 7.2 11.4 1.7 15.6 7.2 36 7 36 305 47.3 0.5 48.4 43.1 01/08/2006 05:40:00 12.2 1.6 15.3 8.4 12 1.6 15.3 8 33 5 36 305 46.1 2 48.4 28.8 01/08/2006 05:50:00 12.2 1.1 14.9 9.5 11.9 1.2 14.5 9.1 31 6 20 305 44.4 1 45.9 34.3 01/08/2006 06:00:00 12.3 1.2 15.3 9.5 12.3 1.1 16.1 9.5 32 5 36 305 43.7 0.4 44.5 42 01/08/2006 06:10:00 12.2 1.1 15.6 9.9 12 1.2 15.6 9.1 33 6 38 305 42.7 0.3 43.4 39.6 01/08/2006 06:20:00 12.3 1.1 14.5 9.1 12 1.1 14.5 8.8 33 5 41 305 42.8 1.8 44.5 25.8 01/08/2006 06:30:00 12.6 1.1 15.6 9.5 12.4 1.1 15.3 9.5 33 5 35 305 43.8 1.9 44.8 25.5 01/08/2006 06:40:00 13 1.3 17.2 10.3 12.8 1.4 16.8 9.9 35 5 43 305 42.8 1 44.5 35.6 01/08/2006 06:50:00 12.6 1.2 15.3 9.9 12.5 1.2 15.6 9.9 37 5 37 305 41.6 1 43.1 38.6 01/08/2006 07:00:00 12.3 1 14.5 9.9 12.1 1.1 14.9 9.5 34 5 40 305 42.4 0.4 43.1 41 01/08/2006 07:10:00 13.5 1.1 15.6 10.3 13.4 1.2 16.1 9.9 35 5 34 305 42.1 0.3 43.1 40.6 01/08/2006 07:20:00 12.9 1.1 16.1 10.3 12.7 1.2 15.6 9.9 39 5 37 305 41.8 2.8 44.1 20.4 01/08/2006 07:30:00 12.6 1.3 16.1 9.5 12.3 1.3 16.8 9.5 37 5 41 305 38.9 3.5 42.4 32 01/08/2006 07:40:00 14 1.1 16.4 11.5 13.7 1.2 16.4 10.7 34 5 31 305 40.3 3.5 42 15.9 01/08/2006 07:50:00 14.5 1.4 17.9 11.5 14.2 1.3 17.6 11.1 33 5 33 305 40.6 0.5 41.7 38.6 01/08/2006 08:00:00 14.6 1.2 17.9 11.8 14.5 1.3 17.9 11.5 36 5 40 305 41 0.4 42 38.9 01/08/2006 08:10:00 13 1 15.3 10.3 12.8 1.1 15.6 9.9 37 5 46 305 40.9 0.6 42.4 38.6 01/08/2006 08:20:00 13.2 1 15.3 10.7 13 1.1 15.3 9.9 34 5 28 305 40.9 0.6 42 35.6 01/08/2006 08:30:00 13.6 1.2 16.4 10.3 13.6 1.1 16.4 10.3 35 5 34 305 40.8 2.4 42.7 17.9 01/08/2006 08:40:00 13 1 15.3 10.7 12.8 1 15.3 9.9 35 4 47 305 41.6 0.3 42.4 40.3 01/08/2006 08:50:00 13.6 1.1 16.1 10.3 13.5 1.2 16.1 10.3 34 4 36 305 41.2 0.4 42 39.3 01/08/2006 09:00:00 13.4 1.1 15.6 9.9 13.2 1 15.6 10.7 32 4 28 305 41.5 0.6 42.7 39.3 01/08/2006 09:10:00 12.8 1 16.1 10.3 12.9 1.1 15.6 9.9 34 5 29 305 39.1 8.3 46.3 18.4 01/08/2006 09:20:00 13.1 1.2 16.1 10.3 13 1.2 16.1 10.3 37 5 35 305 44.7 0.8 45.9 37.2 01/08/2006 09:30:00 13.7 1.1 16.4 10.3 13.7 1.2 16.1 10.3 40 5 46 305 42.8 4.5 44.8 21.9 01/08/2006 09:40:00 12.8 1.2 15.3 9.9 12.6 1.3 16.1 9.1 41 5 40 305 43.9 2.4 46.6 23.7 01/08/2006 09:50:00 12.8 1.1 15.3 10.3 12.7 1.1 15.3 9.9 41 5 46 305 45.7 0.3 46.6 44.5 01/08/2006 10:00:00 12.1 1.3 15.6 9.1 11.9 1.3 15.3 8.4 39 5 41 305 45.2 0.3 45.5 41.7 01/08/2006 10:10:00 11.6 1.2 14.9 8.4 11.5 1.2 14.5 9.1 40 5 41 305 44.7 0.3 45.5 43.8 01/08/2006 10:20:00 11.9 1.3 14.9 8.8 11.9 1.4 15.3 8.8 40 6 36 305 44.1 1.7 45.2 24.6 01/08/2006 10:30:00 11.9 1.2 14.5 9.1 11.8 1.1 14.5 9.1 39 5 44 305 43.1 0.4 44.1 42 01/08/2006 10:40:00 12.1 1.2 15.3 9.1 12.1 1.2 15.3 9.1 42 5 38 305 43.7 1.9 45.5 27 01/08/2006 10:50:00 13.6 1.3 17.2 10.7 13.5 1.4 17.9 10.7 41 5 42 305 43.2 0.5 44.5 41.3 01/08/2006 11:00:00 13.1 1.3 16.4 9.9 13 1.5 16.4 9.5 42 5 39 305 43.2 0.6 44.5 39.3 01/08/2006 11:10:00 12.7 1 15.3 10.3 12.6 1 15.3 9.5 37 5 46 305 43 0.3 43.8 41 01/08/2006 11:20:00 13.7 1.7 17.6 9.9 13.6 1.7 17.2 9.9 39 6 28 305 41.4 2.8 43.4 29.8 01/08/2006 11:30:00 13.2 1.2 16.4 10.3 13 1.3 16.1 9.9 43 6 40 305 42.1 1.4 43.1 29.8 01/08/2006 11:40:00 11.9 1.1 14.9 8.8 11.8 1.1 14.9 8.8 42 5 41 305 42.5 0.6 43.8 40 01/08/2006 11:50:00 12.9 1 15.6 8.8 12.8 1 15.3 9.9 40 5 34 305 37.7 5.9 45.5 29.8 01/08/2006 12:00:00 13.5 1.5 16.4 10.3 13.4 1.5 16.8 9.5 37 5 34 305 42.4 4.5 45.5 30.1 01/08/2006 12:10:00 13.4 1.3 16.4 9.9 13.4 1.4 16.8 9.9 41 6 39 305 44.7 0.8 45.9 40.6 01/08/2006 12:20:00 13.8 1.2 16.4 9.9 13.6 1.3 16.8 9.9 40 5 38 305 43.9 1.1 45.2 31 01/08/2006 12:30:00 13.3 1.3 16.1 9.9 13.1 1.4 16.4 9.9 39 6 31 305 43.9 1.8 45.2 31 01/08/2006 12:40:00 14 1.1 17.6 11.5 13.9 1.1 16.8 11.1 41 5 34 305 43.2 1.5 44.5 30.7 01/08/2006 12:50:00 13.8 1.1 17.2 11.5 13.7 1.1 16.8 10.7 38 6 37 305 42 0.6 43.8 39.6 01/08/2006 13:00:00 14.3 1 17.6 11.8 14.1 1.1 17.6 11.1 33 4 28 305 42.4 0.6 43.8 41.3 01/08/2006 13:10:00 14.4 1.3 17.9 10.7 14.3 1.3 17.6 11.1 36 5 37 305 43.1 1.4 44.8 30.7 01/08/2006 13:20:00 13.6 1.4 16.4 9.9 13.5 1.4 16.4 9.9 35 5 34 305 42.7 2.8 44.8 30.4 01/08/2006 13:30:00 14.8 1.5 19.9 12.2 14.6 1.7 19.5 11.5 34 5 36 305 44.3 0.4 45.2 42.7 01/08/2006 13:40:00 14.5 1.6 18.7 9.9 14.2 1.6 18.3 9.9 36 5 35 305 43.5 0.4 44.5 41.7 01/08/2006 13:50:00 14.3 1.6 18.7 10.3 14.3 1.7 18.7 9.9 39 6 37 305 43.2 2.9 45.5 30.1 01/08/2006 14:00:00 13.3 1.6 17.6 10.3 13.2 1.7 17.6 9.9 38 6 35 305 43.3 1.4 44.5 30.1 01/08/2006 14:10:00 13.6 1.4 16.4 9.9 13.4 1.5 16.8 9.1 38 6 44 305 43.1 1 44.1 30.1 01/08/2006 14:20:00 13.4 1.1 16.1 10.7 13.1 1.1 16.4 10.7 41 5 42 305 42.3 3.1 44.5 29.8 01/08/2006 14:30:00 12.4 1 15.3 9.1 12.3 1.1 14.9 9.1 38 5 38 305 42.6 0.5 43.8 40.6 01/08/2006 14:40:00 13.7 1.5 16.8 9.9 13.5 1.6 16.8 9.9 42 6 43 305 40.5 7 45.2 26.4 01/08/2006 14:50:00 12.7 1.1 15.3 9.9 12.6 1.2 15.6 9.1 42 6 50 305 43.1 1.5 44.5 29.8 01/08/2006 15:00:00 12.4 1.5 16.4 8.8 12.3 1.5 16.8 8.8 40 6 39 305 42.8 2.2 44.8 29.8 01/08/2006 15:10:00 14.2 1.3 17.2 10.7 14.1 1.5 17.6 10.3 41 6 45 305 43 1.7 45.5 29.8 01/08/2006 15:20:00 15.2 1.3 18.3 12.6 15 1.3 17.9 12.6 40 5 40 305 41.9 1.4 43.1 30.1 01/08/2006 15:30:00 14 1.5 17.2 10.3 13.9 1.7 17.6 10.7 43 5 46 305 42.1 1.8 43.8 29.8 01/08/2006 15:40:00 14.7 1.4 17.6 10.7 14.6 1.5 17.9 10.3 42 5 44 305 42.6 0.4 43.4 40.6 01/08/2006 15:50:00 14.1 1.2 16.8 10.3 13.9 1.3 16.8 9.9 43 5 39 305 40 5.9 44.8 29.5 01/08/2006 16:00:00 13 1 15.6 10.7 12.8 1 15.3 10.3 45 5 47 305 42.6 0.5 43.8 38.6 01/08/2006 16:10:00 13.2 1.1 16.4 10.7 13 1.1 15.6 10.3 40 6 36 305 42.6 0.3 43.4 41.3 01/08/2006 16:20:00 12.4 1.2 14.9 8.8 12.2 1.2 15.3 8.8 40 6 41 305 40.2 5 43.8 29.2 01/08/2006 16:30:00 12.4 1.5 15.6 9.5 12.2 1.5 16.4 8.8 40 6 38 305 39.9 6.7 46.3 30.1 01/08/2006 16:40:00 14.2 1.4 16.8 10.7 14 1.5 16.8 9.9 39 5 29 305 42.6 1.9 44.5 30.1 01/08/2006 16:50:00 13.1 1.3 16.4 10.3 13 1.3 16.1 9.9 39 6 35 305 42.7 1.8 44.8 30.1 01/08/2006 17:00:00 14 1.2 16.8 10.7 13.7 1.2 16.4 10.3 41 5 43 305 43.4 1.7 45.9 30.1 01/08/2006 17:10:00 13.6 1.2 16.8 10.3 13.3 1.3 16.4 9.9 38 5 39 305 44.1 0.5 45.2 42 01/08/2006 17:20:00 13.5 1.2 15.6 9.9 13.5 1.2 16.1 9.9 38 4 44 305 43.9 1.3 45.5 29.8 01/08/2006 17:30:00 13.1 1 15.6 10.3 12.9 1 15.3 9.9 38 5 33 305 42.9 1.8 44.5 29.5 01/08/2006 17:40:00 12.4 1 14.5 9.5 12.2 1 14.9 9.9 38 5 35 305 42.7 1.9 45.2 29.5 01/08/2006 17:50:00 12.2 1.1 14.9 9.9 11.9 1.1 14.5 9.5 34 6 35 305 43.1 0.4 44.1 41.3 01/08/2006 18:00:00 13 1 15.6 10.7 12.8 1.1 15.6 9.9 35 6 28 305 42.5 0.5 43.8 35.9 01/08/2006 18:10:00 14.3 1.2 17.2 11.1 14.1 1.3 17.2 10.7 35 5 37 305 43 1.7 44.1 30.4 01/08/2006 18:20:00 13.9 1.2 16.4 11.1 13.6 1.2 16.1 11.1 35 5 32 305 42.9 1.6 44.8 30.4 01/08/2006 18:30:00 14.2 1.1 17.2 11.1 14 1.1 16.8 10.7 34 5 32 305 43.7 0.5 44.5 41.3 01/08/2006 18:40:00 13.2 1.3 16.1 10.7 13 1.3 16.1 10.3 36 6 50 305 42 0.9 43.4 30.7 01/08/2006 18:50:00 11.9 1.3 14.9 9.1 11.7 1.3 15.3 8.8 35 6 41 305 43.2 1.2 44.5 30.7 01/08/2006 19:00:00 13.1 1.1 15.6 9.9 12.9 1.2 15.6 10.3 34 6 35 305 44 0.9 44.5 30.7 01/08/2006 19:10:00 12 1.1 15.6 8.8 11.8 1.2 15.3 8.8 36 5 30 305 44 0.4 44.5 43.1 01/08/2006 19:20:00 12.6 1.4 15.3 8.8 12.3 1.5 15.3 8.4 33 5 27 305 43.4 0.3 44.1 41.3 01/08/2006 19:30:00 13.9 1.2 16.4 10.7 13.8 1.2 16.1 11.1 31 4 27 305 43.5 0.6 46.3 42.4 01/08/2006 19:40:00 12.9 1 15.3 10.3 12.7 1.1 15.3 9.9 32 5 32 305 44.3 0.5 45.5 42.7 01/08/2006 19:50:00 12.6 1.2 16.1 9.5 12.2 1.3 14.9 8.4 31 5 35 305 43.7 0.9 45.5 41.3 01/08/2006 20:00:00 13.1 1.1 15.6 10.7 12.8 1.2 15.6 9.9 31 5 30 305 43.7 0.6 44.8 42 01/08/2006 20:10:00 12.5 1.1 14.5 9.5 12.2 1.1 14.5 9.5 32 5 32 305 44 1.5 45.2 30.4 01/08/2006 20:20:00 13.1 1.6 16.8 9.5 12.9 1.6 16.8 10.3 34 6 32 305 43.6 2.5 45.2 29.8 01/08/2006 20:30:00 13 1.4 16.4 9.1 12.8 1.4 16.4 9.1 38 5 41 305 40 6.2 46.6 31 01/08/2006 20:40:00 12 1 14.1 9.5 11.8 1 14.1 9.5 34 5 35 305 44.4 3.7 47.3 31.4 01/08/2006 20:50:00 13.6 1.4 16.8 10.7 13.4 1.4 17.2 9.5 38 6 45 305 43.9 4.5 47.3 30.7 01/08/2006 21:00:00 14.4 1.3 17.2 11.1 14.3 1.3 17.2 11.1 40 5 44 305 42.8 2.6 45.5 29.5 01/08/2006 21:10:00 15 1.3 18.3 11.5 14.7 1.3 18.7 11.5 37 5 27 305 41.9 1.2 43.1 30.1 01/08/2006 21:20:00 14.4 1.6 19.9 10.7 14.3 1.7 19.1 10.3 39 5 33 305 41.7 3.1 44.1 30.1 01/08/2006 21:30:00 15.3 1.6 19.5 10.7 15.3 1.6 19.9 10.7 38 5 34 305 42.4 1.4 44.1 30.4 01/08/2006 21:40:00 14.8 1.6 18.7 10.3 14.6 1.6 18.3 10.3 35 5 31 305 42.5 1.9 44.1 30.4 01/08/2006 21:50:00 15.3 1.4 17.9 10.3 15.1 1.4 18.3 10.3 40 6 39 305 42.1 2.6 44.5 30.1 01/08/2006 22:00:00 15.6 1.3 19.1 12.2 15.4 1.4 18.7 11.5 37 5 34 305 43.7 2.2 45.2 30.4 01/08/2006 22:10:00 14.6 1.6 18.3 10.7 14.4 1.7 18.7 10.3 39 6 38 305 42.5 2.6 44.5 30.4 01/08/2006 22:20:00 14.2 1.4 17.9 10.3 13.9 1.4 16.8 9.9 41 5 42 305 42.8 2 44.5 30.4 01/08/2006 22:30:00 12.7 1.2 15.6 9.9 12.4 1.3 15.3 9.5 40 6 37 305 42.5 1.2 43.8 30.4 01/08/2006 22:40:00 14.3 1.3 17.9 11.1 14.1 1.2 17.6 11.1 34 5 30 305 42.7 0.4 43.8 39.6 01/08/2006 22:50:00 14.5 1.7 19.1 10.3 14.2 1.7 18.7 9.9 37 6 26 305 43.2 2.9 45.2 30.7 01/08/2006 23:00:00 13.5 1.3 16.4 9.9 13.4 1.2 16.4 9.9 39 5 41 305 43.3 1.1 44.8 30.7 01/08/2006 23:10:00 14 1.5 17.6 10.7 13.8 1.5 17.6 9.9 38 5 43 305 43.8 1 45.5 30.7 01/08/2006 23:20:00 14 1.5 18.3 10.3 13.8 1.6 18.3 9.9 38 5 38 305 43.6 2.7 45.5 30.4 01/08/2006 23:30:00 12.6 1.3 17.2 9.5 12.4 1.2 16.1 9.9 34 6 23 305 42.7 3.4 44.8 30.4 01/08/2006 23:40:00 13.3 1.7 17.9 9.1 13.1 1.7 17.9 9.1 34 6 31 305 43.2 2.5 44.8 30.7 01/08/2006 23:50:00 14.5 1.2 16.8 11.5 14.3 1.3 17.6 10.7 32 5 40 305 43.2 0.2 43.8 40.6 01/09/2006 00:00:00 14.2 1.5 17.6 10.3 14 1.5 17.6 10.3 35 6 36 305 43.3 0.1 43.8 42.7 01/09/2006 00:10:00 13.7 1.6 17.2 9.9 13.4 1.6 16.8 9.5 36 5 35 305 42.8 1.2 43.8 30.1 01/09/2006 00:20:00 14.5 1.4 17.9 11.5 14.3 1.5 17.9 10.7 34 5 33 305 43.1 1.2 44.5 30.4 01/09/2006 00:30:00 13.8 1.3 16.4 10.7 13.6 1.3 16.8 10.3 34 6 21 305 43.2 0.5 44.5 38.6 01/09/2006 00:40:00 14.6 1.4 17.9 10.7 14.4 1.4 17.6 10.3 34 5 41 305 42.9 1.6 44.1 30.4 01/09/2006 00:50:00 14 1.5 17.2 10.7 13.8 1.5 17.6 10.3 34 5 35 305 42.2 2.6 43.8 29.8 01/09/2006 01:00:00 14.4 1.1 17.6 11.1 14.2 1.2 17.6 10.7 37 5 37 305 42.9 1.5 44.5 30.4 01/09/2006 01:10:00 14.7 1.4 19.1 11.5 14.5 1.4 17.6 11.5 33 5 30 305 43.3 1.6 44.5 30.1 01/09/2006 01:20:00 13.8 1.2 16.8 10.7 13.4 1.2 16.4 10.3 32 5 41 305 43.1 1.5 44.1 30.4 01/09/2006 01:30:00 14.7 1.5 19.1 11.1 14.4 1.5 18.3 11.5 33 5 33 305 43.1 1.6 44.5 30.1 01/09/2006 01:40:00 14 1.3 17.2 9.5 13.8 1.4 16.8 9.5 32 6 24 305 42.7 3.1 45.2 30.4 01/09/2006 01:50:00 14.3 1.5 17.6 10.7 13.9 1.5 17.6 10.7 33 6 30 305 38.4 6.2 44.5 30.1 01/09/2006 02:00:00 13.9 1.3 17.9 10.3 13.7 1.2 17.6 10.3 35 6 32 305 42.8 6.2 47.3 31 01/09/2006 02:10:00 13.4 1.7 17.9 9.5 13.3 1.7 17.2 9.9 38 6 39 305 43.2 3.7 46.6 30.4 01/09/2006 02:20:00 13.8 1.1 16.8 11.1 13.7 1.2 16.8 10.3 37 5 48 305 42.9 4.5 46.3 30.4 01/09/2006 02:30:00 14.2 1.6 17.9 10.7 14 1.7 17.6 9.5 37 5 36 305 41.4 6.4 47 30.1 01/09/2006 02:40:00 13.3 1.1 16.4 9.5 13 1.2 15.6 9.5 37 5 32 305 30.7 0.3 31.7 30.1 01/09/2006 02:50:00 13.6 1.4 17.2 9.5 13.3 1.5 16.8 9.5 36 5 38 305 32.9 2.1 36.2 27.6 01/09/2006 03:00:00 13.1 1.3 16.8 9.5 12.9 1.4 16.4 9.5 34 6 24 305 35.3 0.2 35.9 34.6 01/09/2006 03:10:00 13.3 1.5 17.2 9.9 13.1 1.5 16.8 9.9 33 6 39 305 35.2 0.1 35.6 34.6 01/09/2006 03:20:00 13.4 1.3 16.8 10.3 13 1.2 16.8 9.9 32 6 37 305 48.3 5.9 51.4 35.3 01/09/2006 03:30:00 13.5 1.1 16.4 10.7 13.3 1 16.4 10.3 34 5 39 305 51 0.1 51.8 49.9 01/09/2006 03:40:00 13.9 1.3 16.8 9.9 13.6 1.3 16.8 9.5 35 5 39 305 49 2.2 51 40.6 01/09/2006 03:50:00 14.4 1.3 17.6 11.1 14.2 1.4 17.2 10.7 35 5 33 305 43.5 4.7 48.8 35.6 01/09/2006 04:00:00 13.6 1.1 16.4 10.3 13.4 1.1 16.1 10.7 34 5 30 305 45.6 1.1 49.2 36.6 01/09/2006 04:10:00 14 1.2 17.2 11.5 13.6 1.2 16.8 10.7 33 5 32 305 43.8 2.2 46.3 28.2 01/09/2006 04:20:00 12.9 1.2 16.1 9.9 12.8 1.2 16.4 9.5 31 5 30 305 34.9 5.9 47.7 28.5 01/09/2006 04:30:00 12.1 1.2 15.6 9.5 11.9 1.2 15.3 8.8 32 5 33 305 45 2.5 47.3 33.3 01/09/2006 04:40:00 11.8 1.3 15.6 8.8 11.6 1.4 15.6 8.4 32 6 25 305 45.5 1.2 46.6 28.5 01/09/2006 04:50:00 12 1.3 15.3 8.8 11.9 1.3 15.3 8.4 31 5 25 305 46.3 0.7 47.3 40.6 01/09/2006 05:00:00 14.6 1.5 17.6 10.3 14.3 1.5 17.6 9.9 33 4 35 305 45.9 0.1 46.6 45.2 01/09/2006 05:10:00 14.8 1.2 17.9 12.2 14.5 1.2 17.6 11.8 33 5 29 305 45.3 0.2 46.3 44.5 01/09/2006 05:20:00 13.5 1.2 16.1 9.9 13.3 1.1 16.4 10.3 36 5 30 305 44.5 3.5 46.3 31 01/09/2006 05:30:00 13.6 1.2 16.4 10.3 13.4 1.3 16.4 9.9 35 5 33 305 44.7 2.2 45.9 30.4 01/09/2006 05:40:00 13.2 1.5 16.8 10.3 13 1.5 16.8 9.5 35 5 32 305 44.6 0.5 45.9 43.1 01/09/2006 05:50:00 13.7 1.2 16.8 11.1 13.5 1.3 16.4 9.9 34 5 36 305 44.5 2 46.3 28.8 01/09/2006 06:00:00 13.1 1.4 16.1 9.9 12.9 1.4 16.1 9.5 35 5 35 305 44.7 0.2 45.2 42.7 01/09/2006 06:10:00 12.5 1 14.9 9.9 12.3 1 15.3 9.5 34 5 20 305 44.6 0.2 45.2 41.3 01/09/2006 06:20:00 12.9 1.7 17.6 8.8 12.6 1.7 17.9 8.4 32 5 35 305 44.7 2.5 46.6 29.2 01/09/2006 06:30:00 14.3 1.7 18.3 10.3 14.1 1.6 17.9 10.3 33 5 28 305 45.5 2.3 47 30.4 01/09/2006 06:40:00 13.9 1.1 16.4 10.7 13.7 1.2 15.6 10.3 35 5 44 305 44.6 0.9 45.9 30.1 01/09/2006 06:50:00 11.9 1.3 16.1 8.4 11.7 1.3 15.6 8.4 36 5 32 305 44.9 2.5 46.6 29.5 01/09/2006 07:00:00 12.7 1.1 15.3 9.9 12.5 1.3 15.3 9.5 35 5 34 305 45 1.3 46.3 30.4 01/09/2006 07:10:00 12.2 1.4 15.6 9.1 11.9 1.4 15.6 9.1 31 6 30 305 44.5 3.2 46.3 29.2 01/09/2006 07:20:00 13 1.3 15.6 9.5 12.7 1.3 15.3 9.9 32 5 27 305 45.2 0.4 46.3 43.1 01/09/2006 07:30:00 13.2 1.3 15.6 9.5 13 1.3 15.6 9.9 30 5 30 305 45.1 0.2 45.5 44.1 01/09/2006 07:40:00 12.6 1.2 16.1 9.9 12.3 1.2 16.1 9.1 30 5 32 305 40.6 5.9 45.2 11.6 01/09/2006 07:50:00 11.8 1.2 14.5 8.4 11.6 1.2 14.5 8.4 32 6 31 305 49.9 3.2 51.8 32.6 01/09/2006 08:00:00 13.2 1.1 15.6 10.3 12.9 1.1 15.6 9.9 32 5 37 305 50.1 0.5 51 48.8 01/09/2006 08:10:00 11.9 1.3 15.3 8.4 11.7 1.3 14.9 8.8 32 6 30 305 50.4 2.4 52.1 41.3 01/09/2006 08:20:00 12.9 1.5 16.1 9.5 12.7 1.5 16.4 9.1 31 5 29 305 49.7 1.7 51 40.3 01/09/2006 08:30:00 12.7 1.2 15.6 9.1 12.5 1.2 14.9 9.5 28 5 21 305 49.8 0.3 50.6 48.4 01/09/2006 08:40:00 12.4 1.5 15.6 9.5 12.2 1.5 15.6 9.1 27 6 26 305 48.8 1 49.9 38.6 01/09/2006 08:50:00 12.9 1.3 16.1 9.5 12.7 1.4 15.6 9.5 31 6 21 305 47.6 1.8 49.5 37.2 01/09/2006 09:00:00 13.2 1.2 16.4 9.9 12.9 1.3 16.4 9.9 30 5 27 305 47.8 2.9 50.3 35.9 01/09/2006 09:10:00 11.3 1.3 14.5 8.4 11.1 1.3 14.5 8 30 5 38 305 43.6 5.9 51 34.9 01/09/2006 09:20:00 12 1.3 15.6 9.5 11.7 1.3 14.9 9.1 28 5 28 305 46.6 4.2 50.3 35.9 01/09/2006 09:30:00 12.6 1.3 16.4 9.5 12.4 1.2 15.6 9.9 27 5 29 305 38.8 7 49.9 27.6 01/09/2006 09:40:00 12.6 1.2 15.6 9.5 12.3 1.2 15.3 9.1 27 5 27 305 46.8 3.5 49.2 29.2 01/09/2006 09:50:00 11.3 1.1 14.1 8.8 11.1 1.1 13.3 8 29 5 37 305 45 0.5 46.3 43.4 01/09/2006 10:00:00 10.7 1.5 13.3 7.6 10.5 1.5 14.1 7.2 26 6 19 305 43.6 3.4 45.2 28.5 01/09/2006 10:10:00 11.3 1.2 13.7 8.4 11.3 1.1 13.7 8.8 16 4 18 305 44.6 2.7 46.3 29.5 01/09/2006 10:20:00 11.2 1.1 14.1 7.6 11.1 1.2 13.7 7.2 16 5 18 305 46 1.2 47 28.2 01/09/2006 10:30:00 10.7 0.8 12.6 8.4 10.8 0.8 13 8.4 17 5 12 305 46.3 2.5 47.7 28.5 01/09/2006 10:40:00 10.3 1.2 13 7.2 10.3 1.3 13 7.2 18 5 16 305 45.4 0.6 47 42.4 01/09/2006 10:50:00 11.6 1.1 14.1 8.8 11.5 1.2 14.1 8.4 20 5 17 305 46.3 0.3 47.3 44.8 01/09/2006 11:00:00 10.1 1.2 14.1 7.6 10 1.2 14.1 7.2 19 6 13 305 46.6 1.8 47.7 29.8 01/09/2006 11:10:00 11.3 1 13.3 8.8 11.1 1.1 13.3 8.4 25 5 26 305 46.8 0.2 47.3 45.5 01/09/2006 11:20:00 10.5 1.2 13 7.6 10.4 1.2 12.6 7.6 23 5 19 305 46.3 0.3 47.3 43.8 01/09/2006 11:30:00 10.5 1 13 7.6 10.3 1 12.6 7.6 21 5 21 305 45.6 3.4 47.3 27.6 01/09/2006 11:40:00 9.8 1.2 12.6 6.8 9.7 1.2 12.6 6.5 23 5 23 305 46.3 3.7 47.7 28.2 01/09/2006 11:50:00 9.7 1.1 12.2 6.8 9.6 1.2 12.2 6.8 23 5 25 305 45.7 1.6 47.7 29.5 01/09/2006 12:00:00 10.4 1.1 12.6 6.8 10.2 1.2 12.2 6.8 19 5 19 305 44.6 1.5 46.6 30.7 01/09/2006 12:10:00 9.9 0.9 11.8 7.6 9.8 1 12.2 6.8 21 5 13 305 44.2 2.4 46.3 28.8 01/09/2006 12:20:00 10.1 0.9 12.2 7.6 9.9 1 12.2 6.8 20 5 23 305 45.4 3.7 47.7 28.2 01/09/2006 12:30:00 10.1 0.9 11.8 7.6 10 0.9 12.6 7.6 18 5 22 305 46 0.8 47 35.9 01/09/2006 12:40:00 10.4 1.1 12.2 6.8 10.3 1.2 12.6 6.5 18 4 17 305 45.7 2.8 47.7 29.8 01/09/2006 12:50:00 9.8 1 12.2 7.6 9.7 1 11.8 7.6 19 5 25 305 43.2 5.9 47.7 30.7 01/09/2006 13:00:00 9.7 1 12.2 7.2 9.6 1.1 12.2 7.2 20 4 24 305 46.7 2.1 48.8 33 01/09/2006 13:10:00 9.9 0.8 11.5 7.6 9.8 0.9 11.5 7.6 20 4 23 305 45.3 2.9 47.3 31.7 01/09/2006 13:20:00 9.7 0.9 12.2 7.2 9.6 0.8 11.8 7.2 16 5 24 305 45.6 0.3 46.3 41.7 01/09/2006 13:30:00 10 0.8 12.2 8.4 10 0.8 12.2 8 12 5 5 305 39.6 6.7 47.3 30.7 01/09/2006 13:40:00 10.5 0.8 12.2 8.4 10.5 0.9 12.6 8.4 11 5 9 305 33.6 1.8 36.6 30.7 01/09/2006 13:50:00 10.8 1 13 8.4 10.8 1 13 8.4 14 5 8 305 39.8 5.9 49.9 33.9 01/09/2006 14:00:00 11.5 0.7 13 9.1 11.4 0.8 13.3 9.1 18 5 12 305 47.5 4.2 51 32 01/09/2006 14:10:00 11 1 13.3 8.4 10.8 1.1 13.3 8 19 4 19 305 45.8 4.5 49.9 32.3 01/09/2006 14:20:00 11.2 1 13.3 8.8 11.1 1 13.3 8.4 18 4 16 305 46.3 3.7 49.5 34.3 01/09/2006 14:30:00 10.9 1.1 13 7.6 10.8 1.1 13.7 7.6 19 4 22 305 44.8 4.7 49.9 32.3 01/09/2006 14:40:00 11 1.2 13.7 8 11 1.3 13.7 8.4 19 5 17 305 43.7 5.6 48.8 32 01/09/2006 14:50:00 11 1 13.7 8.4 10.9 1 13.3 8 22 5 27 305 40.8 6.4 48.4 31.4 01/09/2006 15:00:00 11.5 0.9 13.7 9.1 11.3 0.9 13.7 8.4 24 4 27 305 45.5 2.4 47.3 32.6 01/09/2006 15:10:00 11 1 13.3 8.8 10.9 1 13.3 8 22 5 23 305 40 6.2 48.4 28.2 01/09/2006 15:20:00 10.1 1.1 13 7.6 10.1 1.1 13 7.6 20 5 21 305 44 6.4 49.9 32.3 01/09/2006 15:30:00 10.9 1.1 13.3 8 10.7 1.2 13.3 8 19 5 21 305 46.1 3.8 49.9 32.3 01/09/2006 15:40:00 11.7 0.9 14.1 9.5 11.6 1 14.1 9.1 23 4 22 305 45 5.2 49.5 31.7 01/09/2006 15:50:00 11.3 0.8 13.3 8.8 11 0.9 13.3 8.4 25 5 23 305 44.6 5.9 49.5 31.7 01/09/2006 16:00:00 12.7 1.4 16.8 9.9 12.5 1.3 16.1 9.5 27 6 33 305 43.9 5.6 48.8 31.7 01/09/2006 16:10:00 12.8 1.2 16.4 9.9 12.5 1.3 16.1 9.1 31 5 32 305 42.6 5.4 48.1 32 01/09/2006 16:20:00 12.3 1.3 14.9 9.5 12 1.2 14.9 8.8 30 5 39 305 36.3 5.2 47.7 29.8 01/09/2006 16:30:00 13.6 1.4 17.2 10.3 13.3 1.5 17.6 9.9 31 5 27 305 43.2 5.2 48.8 32.3 01/09/2006 16:40:00 13.2 1.1 16.1 10.3 12.8 1.2 16.1 9.5 30 5 28 305 44.3 3.7 48.1 33.3 01/09/2006 16:50:00 12.6 1.3 14.9 9.1 12.3 1.3 14.5 8.8 29 5 32 305 46.5 2.5 49.9 33.6 01/09/2006 17:00:00 12.4 1.2 14.9 8.8 12.1 1.2 15.3 8.4 33 5 37 305 46.6 2 48.8 34.3 01/09/2006 17:10:00 12.4 0.9 14.5 9.9 12.1 1 14.9 9.5 31 6 32 305 44.6 5.9 50.6 33.3 01/09/2006 17:20:00 11.2 1.2 14.9 8.4 11 1.2 14.9 8 26 7 32 305 47.5 2.1 49.2 34.3 01/09/2006 17:30:00 10.2 0.8 12.2 8.4 10.1 0.9 12.6 8 19 5 20 305 46.7 2 49.2 33.3 01/09/2006 17:40:00 10.1 0.9 12.6 7.6 10.1 0.9 12.2 8 16 5 17 305 47.5 2.1 49.9 34.3 01/09/2006 17:50:00 10.7 1 13 8 10.7 0.9 13 8 17 5 19 305 46.9 0.8 48.4 38.6 01/09/2006 18:00:00 10.3 0.9 13 8 10.3 1 12.2 8 17 5 15 305 47 1.9 48.8 33.6 01/09/2006 18:10:00 10.5 0.8 12.6 7.6 10.3 0.9 12.6 8 17 5 30 305 47.4 2.4 50.3 33.3 01/09/2006 18:20:00 10.2 1 12.6 7.6 10.1 1 12.2 8 19 5 17 305 47.7 3.2 49.9 33.3 01/09/2006 18:30:00 10.3 1 12.6 6.8 10.3 1.1 12.2 7.2 19 4 16 305 47.4 4.4 50.3 32.6 01/09/2006 18:40:00 9.3 1.1 12.6 6.8 9.2 1.1 12.6 7.2 18 6 14 305 47.3 4.4 50.6 32.6 01/09/2006 18:50:00 9.4 1.1 11.5 6.8 9.3 1.1 12.2 6.5 18 6 19 305 47.2 5.2 51.4 32.6 01/09/2006 19:00:00 10.3 0.9 12.6 7.6 10.2 0.9 13 8 17 5 18 305 43.8 7.6 52.9 33 01/09/2006 19:10:00 10.1 1.1 12.6 7.2 10 1.2 12.6 7.6 17 5 14 305 49 4.5 52.9 33.3 01/09/2006 19:20:00 10.5 0.9 12.6 7.6 10.4 0.9 12.2 8 20 5 21 305 49 0.2 51.4 47.3 01/09/2006 19:30:00 9.8 1 11.8 7.6 9.6 1 11.8 6.8 17 5 12 305 47.7 0.6 48.8 43.8 01/09/2006 19:40:00 9.7 0.9 11.8 7.2 9.7 1 12.2 7.6 18 5 21 305 46.6 1.2 48.4 32.6 01/09/2006 19:50:00 10.5 0.9 12.6 8.4 10.3 0.9 12.2 7.6 20 5 20 305 45 1 46.6 41.3 01/09/2006 20:00:00 8.8 1 11.1 5.7 8.6 1 11.5 6.1 19 5 18 305 44.7 1.8 46.6 31 01/09/2006 20:10:00 9.3 1 11.5 6.5 9.2 1 11.1 6.1 17 5 20 305 45.7 1.9 47.7 31 01/09/2006 20:20:00 9.1 1.1 11.5 6.5 8.9 1 11.8 6.5 20 5 24 305 46.5 4.2 49.5 26.4 01/09/2006 20:30:00 10.2 0.8 12.2 8.4 10.1 0.9 12.2 7.6 20 4 19 305 46.5 4.5 49.5 29.8 01/09/2006 20:40:00 9.9 0.7 11.5 8 9.7 0.8 11.5 7.2 17 4 14 305 46.4 5.2 49.9 31.7 01/09/2006 20:50:00 10.3 1 12.2 8 10.1 1 12.6 7.6 18 5 19 305 46.9 4.5 49.9 30.4 01/09/2006 21:00:00 10.5 0.8 12.2 8 10.3 0.9 12.2 7.6 20 5 16 305 45.8 4.5 49.9 30.7 01/09/2006 21:10:00 10.7 0.8 12.6 8 10.6 0.9 13 8 18 4 17 305 45.3 2.2 49.9 31.7 01/09/2006 21:20:00 9.5 0.9 11.8 7.2 9.3 0.9 11.5 6.8 17 5 24 305 45.1 2.9 49.5 31.7 01/09/2006 21:30:00 9.3 0.9 11.1 6.5 9.2 1 11.5 6.1 18 5 12 305 45.4 5.4 49.5 31 01/09/2006 21:40:00 9 1 11.1 6.5 8.9 1 10.7 6.1 16 5 23 305 45.3 3.5 49.2 31.7 01/09/2006 21:50:00 8.9 0.9 11.1 6.5 8.8 1 11.1 6.5 19 5 17 305 44.8 3.2 48.8 32 01/09/2006 22:00:00 9.1 0.8 11.1 6.8 9.1 0.9 10.7 6.8 17 4 18 305 46.2 4 49.9 32.6 01/09/2006 22:10:00 9.1 0.8 11.1 7.2 9 1 11.1 6.5 16 5 17 305 46.9 3.8 49.9 32.6 01/09/2006 22:20:00 9.1 0.8 11.1 6.8 9.1 0.9 11.1 6.8 16 5 19 305 46.6 4.5 49.9 31.7 01/09/2006 22:30:00 9 0.8 10.7 7.2 8.9 0.8 11.1 7.2 16 5 12 305 44.7 6.2 49.5 31.7 01/09/2006 22:40:00 9.2 0.8 11.1 6.8 9.2 0.8 11.1 6.8 15 4 11 305 46.4 4.2 49.9 32 01/09/2006 22:50:00 8 0.9 10.3 5.7 7.8 0.9 9.9 5.7 15 5 19 305 45.7 3.7 48.4 31.4 01/09/2006 23:00:00 9.5 0.8 11.1 7.2 9.4 0.8 11.1 6.8 16 4 18 305 44.5 6.4 49.5 31.7 01/09/2006 23:10:00 9.1 1 11.1 6.8 8.9 1 11.1 6.5 15 5 12 305 46.1 5.4 49.5 31.7 01/09/2006 23:20:00 9.1 0.8 10.7 6.5 9 0.9 11.1 6.5 15 5 11 305 44.8 6.2 49.5 32 01/09/2006 23:30:00 9 1 11.1 6.1 8.8 1.1 11.5 6.5 15 5 16 305 46.8 4.4 49.5 31.7 01/09/2006 23:40:00 9.1 0.8 10.7 6.8 8.9 0.8 10.7 6.8 18 5 25 305 43.8 7 50.3 31.7 01/09/2006 23:50:00 8.7 1 10.7 6.5 8.5 1 11.1 5.7 23 6 19 305 40.6 7.3 49.5 32.3 01/10/2006 00:00:00 8.8 0.7 10.3 6.8 8.7 0.8 10.7 7.2 21 6 14 305 44.8 6.4 50.3 31 01/10/2006 00:10:00 9.1 0.7 11.1 7.2 8.9 0.8 11.1 6.8 19 6 17 305 46.9 4.5 49.2 30.7 01/10/2006 00:20:00 10 0.6 11.1 8 9.9 0.8 11.8 7.2 17 3 14 305 45.8 5.6 48.8 30.1 01/10/2006 00:30:00 10.2 0.7 11.8 7.6 10.1 0.8 11.8 7.6 15 4 14 305 46.5 4.4 49.2 31.7 01/10/2006 00:40:00 9.7 0.8 11.5 7.2 9.6 0.8 11.5 7.6 14 4 16 305 44.6 6.7 49.2 30.4 01/10/2006 00:50:00 9.4 0.9 11.5 6.5 9.4 1 11.8 6.5 15 5 14 305 46.6 4.4 49.5 31.7 01/10/2006 01:00:00 8.2 1 10.7 6.5 8.1 1 10.3 5.7 20 5 22 305 45.5 5.4 49.2 31 01/10/2006 01:10:00 8.5 0.9 10.3 6.1 8.4 1 10.3 6.1 15 6 12 305 43.5 6.7 49.5 31.7 01/10/2006 01:20:00 8.9 0.8 11.1 6.5 8.8 0.9 10.7 6.5 16 6 25 305 42.5 7.6 49.9 31.7 01/10/2006 01:30:00 9.4 0.8 11.5 7.2 9.2 0.8 11.1 7.2 18 5 19 305 46.3 5 48.8 31.7 01/10/2006 01:40:00 9.1 1 11.1 6.1 9 1 11.5 6.1 16 5 8 305 42.6 6.7 48.4 31.7 01/10/2006 01:50:00 9.2 0.8 11.1 7.2 9.1 0.8 10.7 6.8 18 5 21 305 38.6 6.2 46.6 31.7 01/10/2006 02:00:00 9.3 0.6 10.7 7.6 9.3 0.8 11.1 7.2 20 4 18 305 39.8 7 50.6 32.3 01/10/2006 02:10:00 9 0.9 11.1 6.5 8.9 1 11.1 6.8 17 5 12 305 50.1 1.5 51.4 33 01/10/2006 02:20:00 9.2 0.6 10.7 7.6 9.1 0.7 10.7 6.8 16 3 16 305 48.7 1.7 49.9 34.9 01/10/2006 02:30:00 8.6 0.8 10.3 6.8 8.6 0.8 10.3 6.8 18 4 17 305 47.9 0.9 49.9 41.3 01/10/2006 02:40:00 8.3 0.8 9.9 6.5 8.2 0.7 9.9 6.1 18 5 22 305 42.6 7.3 49.9 31.4 01/10/2006 02:50:00 8.1 0.7 9.5 6.5 8 0.7 9.5 6.1 18 4 19 305 48.3 0.6 49.5 44.1 01/10/2006 03:00:00 8.3 0.7 9.9 6.1 8.1 0.7 9.5 6.5 19 5 18 305 47.8 1.3 48.8 31.4 01/10/2006 03:10:00 8.7 0.7 10.7 6.8 8.6 0.8 11.1 6.8 18 4 19 305 45.8 4.7 48.8 30.4 01/10/2006 03:20:00 8.9 0.6 10.3 6.8 8.6 0.7 10.3 6.5 16 5 14 305 41.2 4.4 48.4 31.7 01/10/2006 03:30:00 8.8 0.9 11.1 6.8 8.6 0.9 11.1 6.5 16 4 13 305 44 7.6 49.5 11.3 01/10/2006 03:40:00 8.8 0.8 10.3 6.1 8.7 0.8 10.7 6.5 18 5 10 305 43.9 8 49.9 29.8 01/10/2006 03:50:00 9.5 0.9 11.1 6.8 9.4 1 11.5 6.5 19 6 14 305 48.1 4.4 50.6 30.4 01/10/2006 04:00:00 9.1 0.9 11.1 6.5 9 0.9 10.7 6.1 22 5 24 305 43 8.3 49.5 16.7 01/10/2006 04:10:00 8.8 1 11.1 6.5 8.7 1 11.5 6.5 23 5 24 305 45.2 7.3 49.5 27.6 01/10/2006 04:20:00 8.4 0.9 10.7 5.7 8.2 1 11.1 5.3 20 6 18 305 44.2 6.7 48.4 28.2 01/10/2006 04:30:00 8.1 1 10.3 5.7 8 1.1 9.9 5.3 16 6 27 305 42.5 7.3 50.3 27.6 01/10/2006 04:40:00 8.3 0.8 9.9 5.7 8.1 0.8 9.9 6.1 13 5 7 305 43.8 7.3 50.3 27.6 01/10/2006 04:50:00 7.5 1 9.9 5.3 7.4 1 9.9 5.3 18 6 21 305 46.4 6.2 50.6 25.5 01/10/2006 05:00:00 9.1 1 10.7 5.7 9 1.1 11.1 5.7 19 5 24 305 44.3 7.6 49.5 25.8 01/10/2006 05:10:00 9 1 11.1 6.5 8.9 1 11.5 6.5 23 6 21 305 44.6 4.7 48.4 27.6 01/10/2006 05:20:00 8.7 0.8 10.7 5.7 8.7 0.8 10.7 5.7 16 6 28 305 45.6 3.2 47.7 27.3 01/10/2006 05:30:00 8.7 0.7 10.3 6.8 8.7 0.8 10.7 6.1 14 4 14 305 46.5 3.1 48.4 26.4 01/10/2006 05:40:00 7.9 0.8 9.9 5.7 7.8 0.8 9.5 5.7 15 5 22 305 43.2 7.3 47.3 25.8 01/10/2006 05:50:00 8.2 0.8 9.5 6.5 8.2 0.8 9.5 4.9 13 5 12 305 43.7 7.3 48.8 27 01/10/2006 06:00:00 8.4 0.8 10.3 6.5 8.3 0.8 9.9 6.5 15 5 21 305 45.1 4 47.7 27 01/10/2006 06:10:00 7.9 0.8 9.5 5.3 7.8 0.8 9.5 5.7 18 6 15 305 46.6 0.6 48.1 44.8 01/10/2006 06:20:00 7.6 0.7 9.5 6.1 7.5 0.6 9.1 5.7 16 5 18 305 45.6 3.8 47.7 26.1 01/10/2006 06:30:00 8.1 0.8 9.9 5.7 8 0.8 9.9 5.7 11 6 22 305 41.9 9.1 50.6 27.6 01/10/2006 06:40:00 7.8 1 9.9 5.3 7.9 1 9.9 5.3 11 5 20 305 43.4 8.3 49.9 27 01/10/2006 06:50:00 8.2 0.8 10.3 6.5 8 0.8 9.5 6.1 12 5 11 305 48.4 5 50.6 27.6 01/10/2006 07:00:00 7.5 0.7 9.5 5.3 7.3 0.8 9.5 4.9 14 6 10 305 48.3 4.7 50.6 31.7 01/10/2006 07:10:00 7.8 0.6 9.5 5.3 7.7 0.7 9.5 5.7 11 4 12 305 48.3 0.8 49.9 41 01/10/2006 07:20:00 7.6 0.6 9.1 6.1 7.6 0.6 9.1 5.7 12 5 17 305 47 4.2 50.3 30.4 01/10/2006 07:30:00 6.9 0.8 8.4 4.9 6.9 0.8 8.8 4.9 11 5 7 305 47.7 0.3 48.4 45.9 01/10/2006 07:40:00 7.3 0.8 8.8 5.3 7.4 0.8 8.8 4.9 10 5 14 305 46.3 5 50.6 28.5 01/10/2006 07:50:00 7.2 0.9 8.8 5.3 7.1 0.8 9.1 5.3 14 5 16 305 38.8 10.4 52.9 27.6 01/10/2006 08:00:00 7.6 0.6 9.1 5.7 7.5 0.7 9.1 5.3 14 5 16 305 46.4 4.4 51 28.2 01/10/2006 08:10:00 7.3 0.8 9.1 5.3 7.2 0.8 9.1 4.9 11 5 12 305 43.9 5.2 46.6 27.3 01/10/2006 08:20:00 7.1 0.7 8.8 4.9 7 0.8 8.8 5.3 10 5 14 305 44.3 8 51.4 27.9 01/10/2006 08:30:00 7.1 0.8 8.8 5.3 7.1 0.8 9.1 5.3 7 5 10 305 46.3 3.7 48.4 28.5 01/10/2006 08:40:00 7.2 0.7 8.4 4.9 7.2 0.8 9.5 4.9 9 5 7 305 43.9 9.5 51 24 01/10/2006 08:50:00 7.5 0.5 8.8 6.1 7.4 0.5 8.8 6.1 8 4 15 305 44.3 8.3 49.9 27 01/10/2006 09:00:00 7 0.7 8.4 5.3 7 0.8 8.8 4.9 6 5 9 305 45.6 8 50.6 27.3 01/10/2006 09:10:00 6.9 0.7 8.4 4.9 6.9 0.8 8.4 4.9 7 5 9 305 46.2 6.4 49.9 27.3 01/10/2006 09:20:00 6.7 0.8 8.8 4.6 6.7 0.9 8.8 4.6 8 6 13 305 43.9 7.6 49.2 27.6 01/10/2006 09:30:00 7.8 0.6 9.1 5.7 7.7 0.6 9.1 6.1 7 4 11 305 46.1 4.5 48.8 27.9 01/10/2006 09:40:00 7.1 0.8 8.8 4.9 7.1 0.9 9.5 4.9 8 5 9 305 46.2 2.9 48.4 27.6 01/10/2006 09:50:00 7.3 0.6 8.8 5.3 7.3 0.6 8.8 5.7 9 4 11 305 41.2 8.3 48.8 27.3 01/10/2006 10:00:00 7 0.6 8.8 5.3 7 0.6 8.8 5.3 8 5 11 305 46 5.9 49.5 28.2 01/10/2006 10:10:00 6.8 0.9 9.1 4.6 6.7 0.9 8.8 4.9 12 5 14 305 46.1 5 49.2 27.6 01/10/2006 10:20:00 7.2 0.8 9.5 4.9 7.2 0.7 9.1 4.9 9 5 13 305 38.1 9.1 48.8 27.6 01/10/2006 10:30:00 7.4 0.9 9.1 4.9 7.4 1 9.1 4.9 10 6 9 305 36.2 8.3 48.1 27 01/10/2006 10:40:00 7.5 0.9 9.1 5.7 7.6 0.8 9.5 5.7 9 5 0 305 32.6 7.3 47 27.3 01/10/2006 10:50:00 7.3 0.7 9.1 5.3 7.2 0.7 9.1 5.7 8 5 7 305 42 7.3 48.1 27.3 01/10/2006 11:00:00 7.5 0.8 9.1 5.3 7.3 0.8 9.1 5.3 10 5 6 305 43.6 5 47.3 26.7 01/10/2006 11:10:00 7.9 0.9 10.3 6.1 7.7 0.8 9.5 5.7 12 4 5 305 46.7 3.8 48.8 27 01/10/2006 11:20:00 8.1 0.8 9.5 5.7 8.1 0.8 9.5 5.7 9 5 12 305 47.6 1.4 48.8 26.7 01/10/2006 11:30:00 8.1 0.9 9.9 5.3 8 1 10.3 5.7 9 4 7 305 45.5 6.7 49.2 24.9 01/10/2006 11:40:00 8.2 0.8 10.3 6.1 8.3 0.8 9.9 6.1 9 3 8 305 45 7.6 49.9 25.8 01/10/2006 11:50:00 8.1 0.6 9.9 6.1 8.1 0.6 10.3 6.5 8 4 8 305 44.3 8.7 49.9 21.9 01/10/2006 12:00:00 7.6 0.8 9.5 5.7 7.6 0.8 9.5 5.7 10 4 7 305 43.6 8.7 49.5 24.9 01/10/2006 12:10:00 7.8 0.8 9.5 5.7 7.7 0.9 9.9 5.7 8 6 12 305 44.1 8.7 51 27.6 01/10/2006 12:20:00 7.9 0.9 9.5 4.9 8 0.8 9.9 5.3 3 6 357 305 46.4 7.6 51.4 27.3 01/10/2006 12:30:00 7.9 0.8 9.9 6.1 8 0.9 10.3 5.7 4 5 0 305 46.7 7.3 51 27.6 01/10/2006 12:40:00 7.5 1 10.3 5.3 7.5 1 10.3 4.6 5 6 4 305 46.6 6.7 50.6 27 01/10/2006 12:50:00 7.1 0.7 9.1 4.9 7.2 0.9 9.1 5.3 8 6 10 305 46.7 6.7 50.6 27.6 01/10/2006 13:00:00 7.6 1 9.5 5.3 7.6 1 9.9 5.3 9 5 10 305 46.1 6.4 50.3 25.8 01/10/2006 13:10:00 7.1 0.8 9.1 5.3 7.1 0.7 9.1 5.3 11 5 12 305 45.9 6.2 49.2 26.4 01/10/2006 13:20:00 6.8 0.8 8.8 4.9 6.8 0.8 8.8 4.6 12 5 17 305 45.8 6.7 49.5 25.2 01/10/2006 13:30:00 7.1 0.7 8.8 5.3 6.9 0.7 8.8 5.3 11 5 12 305 46.2 6.4 49.5 26.7 01/10/2006 13:40:00 6.9 0.8 8.8 4.9 6.8 0.9 9.1 4.9 8 5 9 305 42.5 10.4 51 25.5 01/10/2006 13:50:00 7.2 0.9 9.5 5.3 7.1 0.9 9.5 5.3 7 6 2 305 47.8 5.2 51 26.4 01/10/2006 14:00:00 6.9 0.7 8.8 5.3 6.9 0.7 8.8 5.3 8 5 10 305 46.9 4.7 49.5 26.1 01/10/2006 14:10:00 8.2 0.8 9.9 6.1 8.1 1 10.3 5.3 10 5 11 305 39 9.9 49.2 24.6 01/10/2006 14:20:00 8.1 0.8 9.5 6.1 8.1 0.8 10.3 6.1 3 6 0 305 42.4 9.1 49.9 25.5 01/10/2006 14:30:00 8 0.8 9.9 5.7 8 1 9.9 6.1 5 5 13 305 42.5 8.7 48.8 25.5 01/10/2006 14:40:00 8.1 1 10.7 5.3 8 1.1 10.7 5.3 4 5 0 305 44.6 7 49.2 24.9 01/10/2006 14:50:00 7.8 0.8 10.3 5.7 7.8 0.8 9.9 5.7 7 5 5 305 45.1 7.6 50.3 22.2 01/10/2006 15:00:00 8.2 1 10.7 5.7 8.3 1 10.7 5.7 5 5 10 305 46.6 7.3 51 16.7 01/10/2006 15:10:00 7.7 0.9 9.5 5.3 7.7 0.9 9.5 5.3 3 6 0 305 46.1 5.4 49.9 22.8 01/10/2006 15:20:00 8.4 0.8 9.9 6.1 8.4 1 10.7 6.1 4 4 3 305 46.7 6.2 49.9 22.5 01/10/2006 15:30:00 8.4 1 11.1 5.3 8.5 1 10.3 5.7 4 4 4 305 43.5 8.7 49.9 23.1 01/10/2006 15:40:00 8.6 0.7 9.9 6.5 8.6 0.8 10.3 6.5 0 5 2 305 47.9 1.4 49.9 27.6 01/10/2006 15:50:00 7.7 0.8 9.5 5.3 7.8 0.9 10.3 5.7 6 5 1 305 43.2 8.7 49.9 25.8 01/10/2006 16:00:00 8.2 0.9 10.3 5.7 8.2 1 10.3 6.1 1 5 1 305 47.8 2.4 49.9 32.6 01/10/2006 16:10:00 8.4 1 10.7 5.7 8.4 1.1 11.1 6.1 2 6 358 305 47.5 1 49.5 37.2 01/10/2006 16:20:00 8.8 0.8 11.1 6.5 8.7 0.9 11.1 6.5 4 5 9 305 46.3 0.6 47.7 44.5 01/10/2006 16:30:00 8.4 1.1 11.8 5.7 8.4 1.2 11.8 5.7 2 7 10 305 44.7 7.3 51 26.1 01/10/2006 16:40:00 8.9 1 11.5 6.5 8.8 1 11.5 6.1 5 6 14 305 34.2 10.8 51.4 24.9 01/10/2006 16:50:00 8.7 0.8 10.3 6.5 8.7 0.8 10.7 6.5 3 5 7 305 26.4 0.5 27.3 23.7 01/10/2006 17:00:00 8.3 0.9 10.3 6.5 8.2 1 10.7 5.7 359 5 358 305 43.9 7.6 49.2 26.1 01/10/2006 17:10:00 8.2 0.8 10.3 6.1 8.2 0.9 10.7 6.1 359 6 8 305 43.4 7.6 48.8 26.1 01/10/2006 17:20:00 7.7 0.9 9.5 5.7 7.7 1 9.9 5.3 357 6 355 305 45.9 3.5 48.4 26.1 01/10/2006 17:30:00 8.4 1.1 10.7 5.7 8.4 1.2 11.5 5.7 2 5 359 305 45.1 3.1 47.7 26.1 01/10/2006 17:40:00 8.2 0.7 9.9 5.7 8.2 0.8 9.9 6.1 7 5 6 305 43 6.2 47 24.9 01/10/2006 17:50:00 8.1 0.8 9.5 5.7 8.1 0.9 10.3 5.7 4 5 13 305 46.7 2.1 48.1 26.7 01/10/2006 18:00:00 8.6 0.9 10.7 6.1 8.6 0.9 11.1 5.7 4 5 358 305 46 1.7 47.3 27 01/10/2006 18:10:00 8.4 1 10.7 5.7 8.4 1 10.7 6.1 8 5 12 305 42.5 7.3 49.2 25.2 01/10/2006 18:20:00 8.1 0.8 9.9 5.7 8.1 0.8 9.9 6.1 7 4 10 305 45.7 8 51.8 26.1 01/10/2006 18:30:00 7.9 0.8 9.9 5.7 7.7 0.9 9.9 5.7 4 5 356 305 49.5 1.2 51.8 42.7 01/10/2006 18:40:00 7.4 0.8 9.1 4.9 7.4 0.8 9.1 4.6 6 5 7 305 46.6 3.5 49.5 27.3 01/10/2006 18:50:00 8.5 1 11.1 6.1 8.4 0.9 11.1 5.7 3 6 358 305 47.7 5.2 51 26.7 01/10/2006 19:00:00 7.7 1 9.9 5.3 7.7 1 9.9 5.7 2 6 0 305 48 2.1 49.9 27.6 01/10/2006 19:10:00 7.8 0.8 9.9 5.7 7.7 0.9 9.9 5.7 5 6 2 305 46.3 4.5 49.2 26.7 01/10/2006 19:20:00 8 0.9 9.9 5.7 8 0.9 10.3 6.1 7 5 6 305 44.2 8.7 51 27.3 01/10/2006 19:30:00 9.3 1 11.1 5.3 9.2 1 11.5 5.7 7 4 7 305 49.3 0.6 50.6 47.7 01/10/2006 19:40:00 8.1 1.1 11.5 6.1 7.9 1.1 10.7 5.7 6 6 5 305 39.4 9.9 49.2 27 01/10/2006 19:50:00 9.2 0.8 10.7 6.1 9 0.8 10.7 6.5 6 5 359 305 48.2 0.5 49.5 46.6 01/10/2006 20:00:00 8.5 0.9 10.3 6.1 8.4 1 10.7 6.5 5 6 358 305 40.5 9.1 48.8 27.3 01/10/2006 20:10:00 8.9 1.2 11.8 6.1 8.8 1.3 11.8 5.7 6 6 5 305 44.9 4.7 47.7 27.3 01/10/2006 20:20:00 8.5 0.9 11.1 6.1 8.5 0.9 11.1 6.1 6 5 5 305 45.5 3.4 48.4 29.2 01/10/2006 20:30:00 8.7 1.1 11.1 6.5 8.6 1.1 11.5 5.7 7 5 2 305 43.2 5.2 47.3 27.9 01/10/2006 20:40:00 9.1 1.1 11.8 6.1 9.1 1.1 11.8 6.5 7 6 4 305 45.9 6.4 49.9 27.9 01/10/2006 20:50:00 8.8 1 11.5 6.5 8.9 1 11.5 6.5 7 6 12 305 38.9 9.1 49.9 28.2 01/10/2006 21:00:00 9 1.1 11.5 6.1 8.9 1.2 11.8 5.7 2 6 4 305 49.1 1.9 51 31.4 01/10/2006 21:10:00 9.4 1.2 12.6 6.5 9.3 1.2 11.8 6.5 6 6 11 305 45.5 4.5 47.7 28.5 01/10/2006 21:20:00 8.9 1.2 11.8 6.1 8.9 1.3 12.2 6.5 10 7 3 305 45.2 6.4 49.5 27.6 01/10/2006 21:30:00 9.6 1.1 11.8 7.2 9.6 1.2 12.2 6.8 8 5 5 305 40 8.7 48.8 26.7 01/10/2006 21:40:00 9.9 1 12.6 7.2 9.9 1.1 13 7.2 12 5 15 305 44.5 0.6 45.5 42 01/10/2006 21:50:00 9.7 1 12.2 6.8 9.7 1 11.5 6.8 10 5 13 305 36.2 8.7 48.8 25.5 01/10/2006 22:00:00 10.4 1 12.6 7.6 10.3 1.1 12.6 7.6 12 5 9 305 44.3 5.9 47.7 28.2 01/10/2006 22:10:00 10.4 1.2 13 7.2 10.3 1.2 13 6.8 12 5 9 305 46.4 2.7 49.5 29.5 01/10/2006 22:20:00 10 1.1 12.6 7.2 9.9 1.1 12.2 6.8 12 5 8 305 48 0.5 49.5 46.3 01/10/2006 22:30:00 9.9 1.1 12.2 6.5 9.8 1.1 12.6 6.8 14 6 21 305 46.7 5.2 51.8 28.2 01/10/2006 22:40:00 9.3 1.2 11.8 6.5 9.3 1.2 11.8 6.5 8 5 11 305 42.4 9.9 52.9 27.9 01/10/2006 22:50:00 9 1.1 12.6 6.5 9 1.2 11.8 6.1 10 5 8 305 42.9 10.8 52.9 27.6 01/10/2006 23:00:00 8.6 0.9 11.1 6.5 8.4 0.9 11.1 5.7 16 6 9 305 41.8 11.8 52.9 26.7 01/10/2006 23:10:00 9.5 1.1 11.8 6.5 9.5 1.1 11.8 6.5 14 5 19 305 47.4 8.7 52.5 24.3 01/10/2006 23:20:00 9.3 1 11.1 6.8 9.1 1 11.5 6.5 16 5 18 305 47.1 7.6 52.9 24.6 01/10/2006 23:30:00 9.5 0.9 11.1 7.2 9.4 1 11.5 6.5 11 4 11 305 48.7 5.2 52.9 28.8 01/10/2006 23:40:00 8.9 1.1 11.5 6.1 8.8 1.1 11.1 6.1 13 6 12 305 42.3 8.3 52.5 27 01/10/2006 23:50:00 10 1.1 12.6 6.8 9.9 1.2 12.6 6.5 15 5 17 305 44.2 9.1 52.9 29.2 01/11/2006 00:00:00 10.2 1.2 12.6 7.6 10 1.3 13 6.8 22 5 12 305 48.7 5 52.9 29.5 01/11/2006 00:10:00 9.3 0.9 11.1 6.1 9.3 0.9 11.5 6.8 16 9 22 305 46.6 6.2 52.1 29.5 01/11/2006 00:20:00 9.2 1.1 11.5 6.5 9.2 1.1 11.8 6.5 10 5 15 305 47.3 2.1 49.5 30.1 01/11/2006 00:30:00 10.3 0.9 12.2 7.6 10.3 1 12.6 7.6 11 4 13 305 47.3 4.7 52.1 30.1 01/11/2006 00:40:00 9.8 1 12.2 7.2 9.6 1 12.2 7.2 11 7 12 305 48.5 3.7 52.9 29.5 01/11/2006 00:50:00 10.1 1 12.2 8 10.1 1 12.6 8 12 5 12 305 46.6 5.2 52.1 26.4 01/11/2006 01:00:00 10.5 0.9 12.2 7.6 10.4 1 12.2 8 16 4 13 305 46.8 6.2 52.5 23.1 01/11/2006 01:10:00 10.4 0.8 12.2 8.4 10.1 0.9 12.2 7.6 17 4 22 305 45.7 7.6 52.9 22.2 01/11/2006 01:20:00 10.6 1 12.6 7.2 10.4 1.1 12.6 7.2 14 5 17 305 48.3 6.4 52.9 28.2 01/11/2006 01:30:00 9.8 1.1 12.2 7.6 9.6 1 12.2 7.2 13 5 16 305 38.8 9.1 52.5 25.5 01/11/2006 01:40:00 10.8 1 13 8 10.6 1 13 8 14 4 9 305 49.4 5.6 52.5 31.7 01/11/2006 01:50:00 11.1 0.9 13 8 10.9 1 13 8.4 15 4 13 305 48.8 4.7 51 27.6 01/11/2006 02:00:00 11.2 1 13.3 8.8 11.1 1 13 8.4 14 5 22 305 49.3 2.6 51 31.7 01/11/2006 02:10:00 10.4 1.5 13.3 7.2 10.2 1.3 13.3 7.2 18 6 20 305 48.1 5.2 51 31.4 01/11/2006 02:20:00 9.8 1 11.8 7.2 9.6 1 12.2 7.2 17 6 13 305 49.4 1.1 51.4 36.2 01/11/2006 02:30:00 10.3 1.1 13 7.6 10.1 1.1 13 7.6 16 5 18 305 48.2 4.2 51 31.7 01/11/2006 02:40:00 10.3 1 12.6 7.6 10.2 1 12.6 8 14 5 18 305 48.6 3.4 50.6 29.8 01/11/2006 02:50:00 10.2 1.1 12.6 7.6 10.1 1.1 12.6 7.2 14 5 13 305 48.9 1.7 50.6 31 01/11/2006 03:00:00 9.8 1 12.6 7.2 9.7 1.1 12.6 7.6 18 6 16 305 48.9 1.6 49.9 30.1 01/11/2006 03:10:00 9.8 1.2 12.6 6.8 9.6 1.2 12.6 6.8 17 5 18 305 47.5 3.8 49.9 28.8 01/11/2006 03:20:00 10.3 1 12.2 7.6 10.1 1 12.2 7.2 18 5 7 305 48.1 1.1 48.8 29.8 01/11/2006 03:30:00 11.5 1.2 14.1 7.6 11.2 1.2 14.5 8.4 18 5 26 305 46.9 5.9 51.8 28.8 01/11/2006 03:40:00 12.2 1.1 14.5 8.8 11.9 1.2 14.5 8.8 22 5 22 305 48.2 3.7 51 29.5 01/11/2006 03:50:00 11.3 1 14.5 8.4 11.1 1.1 13.7 8.4 21 6 30 305 48.6 3.8 51.8 30.4 01/11/2006 04:00:00 11.2 1.2 13.7 7.6 11.1 1.2 13.7 8 12 5 8 305 48.8 3.4 51 30.4 01/11/2006 04:10:00 11.6 1.2 14.5 8.4 11.5 1.2 14.9 8.4 17 5 12 305 49.1 1.2 49.9 30.1 01/11/2006 04:20:00 10.2 1.3 14.9 6.8 10.1 1.3 14.1 6.8 11 6 19 305 48.1 3.2 49.9 29.2 01/11/2006 04:30:00 10.1 1.1 13.7 7.6 9.9 1.1 14.5 7.2 9 6 9 305 47.6 2.8 49.5 29.2 01/11/2006 04:40:00 10.1 1 13.3 6.8 10 1 12.6 7.6 8 6 1 305 47.6 4 49.5 29.2 01/11/2006 04:50:00 10.3 1.2 13 6.8 10.2 1.2 13.3 6.8 5 6 359 305 47.3 2.7 49.2 28.8 01/11/2006 05:00:00 9.9 1.1 13 7.6 9.9 1.1 13 7.2 6 6 8 305 47.4 2.8 49.2 28.8 01/11/2006 05:10:00 10.8 0.8 12.6 8.4 10.8 0.9 13 8.4 3 6 2 305 48.8 0.2 49.5 48.4 01/11/2006 05:20:00 9.5 1 11.8 6.8 9.4 1.1 11.8 6.8 3 6 0 305 48.2 3.2 49.9 29.8 01/11/2006 05:30:00 10 1 12.6 6.8 10 1.1 12.2 7.2 8 6 10 305 48.7 3.8 51.4 30.1 01/11/2006 05:40:00 9 0.8 11.1 6.5 8.9 0.8 11.1 6.8 6 6 3 305 48.9 2.8 50.3 29.5 01/11/2006 05:50:00 9.1 1 11.8 6.8 9 1 11.8 6.5 14 6 16 305 48.2 1.4 49.5 44.1 01/11/2006 06:00:00 8.5 1.2 11.8 6.1 8.4 1.3 11.5 5.7 12 6 19 305 48.5 2.3 49.9 29.5 01/11/2006 06:10:00 8.6 0.9 11.5 6.5 8.6 1 11.5 5.7 9 5 6 305 49.2 2.6 50.6 29.8 01/11/2006 06:20:00 8.5 0.8 11.1 6.1 8.4 0.9 11.1 6.1 11 6 17 305 48.2 2.1 49.5 29.2 01/11/2006 06:30:00 8.6 1 11.1 6.1 8.4 1 10.7 5.7 14 5 13 305 48.2 1.8 49.9 29.8 01/11/2006 06:40:00 9.1 1 11.5 6.5 9 1 11.8 6.5 15 5 12 305 43.3 9.5 52.9 29.2 01/11/2006 06:50:00 8.9 1.1 11.5 6.5 8.7 1 11.5 6.5 16 6 14 305 45.1 9.9 52.9 29.2 01/11/2006 07:00:00 9.6 1.1 12.2 7.2 9.5 1.1 12.2 7.2 19 6 18 305 47.8 8.3 52.9 28.5 01/11/2006 07:10:00 9.9 1 12.2 7.2 9.6 1 12.2 6.8 17 5 22 305 49.2 7.6 52.9 29.8 01/11/2006 07:20:00 9.8 0.8 12.2 7.6 9.5 0.8 12.2 6.8 22 6 17 305 49.7 7.3 52.9 29.5 01/11/2006 07:30:00 9.2 0.9 11.8 7.6 8.9 1 11.8 6.8 21 5 28 305 50.3 6.4 52.9 29.8 01/11/2006 07:40:00 8.4 0.8 10.3 6.5 8.1 0.8 10.7 5.7 20 5 25 305 50.7 5.6 52.9 29.2 01/11/2006 07:50:00 9.1 1 11.5 6.8 9 1.1 11.5 6.5 15 6 17 305 50.8 5.6 52.9 29.2 01/11/2006 08:00:00 8.4 0.9 10.3 6.1 8.2 0.9 10.7 6.1 14 6 10 305 50.3 5.9 52.9 29.8 01/11/2006 08:10:00 8.6 1.1 11.1 6.1 8.3 1 10.7 6.1 19 7 22 305 48 8 52.9 28.8 01/11/2006 08:20:00 9.1 0.9 11.5 6.8 8.9 1 11.8 6.5 17 6 14 305 47.8 6.7 52.9 28.8 01/11/2006 08:30:00 9.3 0.9 11.1 6.5 9.3 0.9 11.5 7.2 16 5 15 305 50.8 5.6 52.9 28.8 01/11/2006 08:40:00 8.8 0.9 11.1 6.5 8.6 1 10.7 6.1 15 4 10 305 50.2 6.4 52.9 28.8 01/11/2006 08:50:00 8.2 1.3 11.1 5.3 8.2 1.3 11.1 5.3 13 5 12 305 48.6 8.3 52.9 28.2 01/11/2006 09:00:00 8.4 0.8 9.9 6.1 8.2 0.7 9.9 6.5 13 5 13 305 50.3 6.7 52.9 28.2 01/11/2006 09:10:00 8.1 0.9 10.3 6.1 8 1 10.7 6.1 11 5 0 305 49.8 7 52.9 28.2 01/11/2006 09:20:00 8.1 1.1 10.3 5.7 8 1 10.3 5.7 16 5 13 305 48.5 8.7 52.9 28.2 01/11/2006 09:30:00 7.4 0.9 9.1 4.9 7.3 0.9 9.5 5.3 14 4 8 305 50 6.7 52.9 28.2 01/11/2006 09:40:00 6.6 1 9.1 4.6 6.5 1 8.8 4.6 15 5 14 305 50 6.4 52.9 28.5 01/11/2006 09:50:00 7.3 0.9 9.1 4.6 7.1 0.9 9.5 4.6 16 5 13 305 44.4 11.3 52.9 28.2 01/11/2006 10:00:00 7.6 1 10.3 5.7 7.6 1 9.9 5.3 15 5 14 305 49.7 7.6 52.9 28.2 01/11/2006 10:10:00 6.2 1 8.8 4.2 6.1 1 8.8 4.2 12 5 11 305 44.7 9.5 52.9 27.9 01/11/2006 10:20:00 7 0.7 9.1 4.9 6.9 0.8 8.8 4.6 17 6 15 305 48.7 4.2 50.6 27.9 01/11/2006 10:30:00 7.6 0.9 9.9 5.3 7.5 1 9.9 5.3 12 7 12 305 47.8 5.6 51 28.2 01/11/2006 10:40:00 8.4 0.8 9.9 6.1 8.2 0.9 9.9 5.7 12 5 10 305 48 4.2 50.6 28.2 01/11/2006 10:50:00 8.4 0.7 9.9 6.1 8.3 0.7 9.9 6.1 11 4 12 305 47.2 5.2 50.3 26.1 01/11/2006 11:00:00 7.7 1 10.7 5.3 7.5 1 9.9 5.3 12 5 22 305 47.4 3.4 49.9 28.2 01/11/2006 11:10:00 8.2 0.9 10.7 6.1 8.1 0.9 10.7 5.7 12 7 20 305 48 2.7 50.3 28.2 01/11/2006 11:20:00 7.8 0.9 9.5 5.7 7.7 0.9 9.9 5.7 16 5 22 305 49 1.8 49.9 28.2 01/11/2006 11:30:00 8.3 0.8 10.3 6.1 8.1 0.9 10.3 6.1 18 5 23 305 43.3 9.5 51.8 28.2 01/11/2006 11:40:00 8.3 0.7 9.5 6.5 8.2 0.8 9.9 6.1 18 4 15 305 46.9 7 51.4 28.5 01/11/2006 11:50:00 8.4 0.9 10.3 6.1 8.2 0.8 9.9 6.1 19 5 17 305 48.9 4.2 52.1 28.5 01/11/2006 12:00:00 8.2 0.8 10.3 6.1 8 0.9 10.3 5.7 18 5 11 305 48.6 3.5 51.4 28.5 01/11/2006 12:10:00 8.2 1.1 10.7 5.3 8.1 1 10.7 4.9 20 5 21 305 47.7 5.2 51 28.2 01/11/2006 12:20:00 8.6 0.8 10.3 6.5 8.5 0.9 10.7 5.7 20 4 17 305 46.5 4.7 50.3 28.2 01/11/2006 12:30:00 8.5 0.8 11.1 6.8 8.4 0.9 11.5 6.5 18 5 14 305 43.7 4.7 47.3 27.9 01/11/2006 12:40:00 9.4 1.1 11.5 6.1 9.3 1.1 11.5 6.1 20 6 11 305 45.6 2.9 48.8 28.2 01/11/2006 12:50:00 9 1 11.5 6.1 8.8 1.1 11.8 6.1 20 6 18 305 43.9 5.4 48.8 27.9 01/11/2006 13:00:00 8.4 1 11.5 6.1 8.2 1.1 11.5 5.7 24 7 13 305 45.8 2.7 48.8 28.2 01/11/2006 13:10:00 8.7 1 11.5 6.5 8.5 1 11.8 6.5 24 8 13 305 44.4 3.7 47.3 27.9 01/11/2006 13:20:00 8.5 0.9 11.1 6.5 8.4 1 11.1 5.7 27 6 23 305 45.5 3.7 47.3 28.2 01/11/2006 13:30:00 8.6 1 10.7 6.1 8.4 1 10.7 6.1 25 5 26 305 46.7 0 47.3 46.6 01/11/2006 13:40:00 8 0.7 10.3 6.1 7.9 0.7 9.9 6.1 31 5 26 305 46.4 0.4 47 42.4 01/11/2006 13:50:00 8.9 0.9 10.7 6.8 8.8 0.9 11.1 6.8 23 4 29 305 44.7 2.1 45.9 27.9 01/11/2006 14:00:00 7.8 0.8 9.5 5.7 7.6 0.8 9.5 5.3 31 5 30 305 46.2 2.4 48.1 27.9 01/11/2006 14:10:00 6.8 0.8 8.4 4.9 6.7 0.8 9.1 4.6 30 7 19 305 46.2 2 48.1 27.6 01/11/2006 14:20:00 7 0.8 8.8 5.3 6.8 0.8 9.5 4.9 27 6 22 305 46 0 46.3 45.5 01/11/2006 14:30:00 7.2 0.8 8.8 5.3 7.1 0.7 9.1 5.3 32 6 36 305 45.1 4.7 48.4 27.6 01/11/2006 14:40:00 7.2 0.8 9.1 4.9 7 0.9 8.8 4.9 28 5 32 305 45.8 4.2 48.8 27.6 01/11/2006 14:50:00 7.3 0.6 9.1 5.3 7.2 0.6 9.1 6.1 36 6 38 305 46.2 0.6 46.6 37.2 01/11/2006 15:00:00 6.4 0.7 8.4 4.6 6.2 0.8 8.4 4.6 38 5 31 305 46.3 2.5 48.8 27.6 01/11/2006 15:10:00 7.2 0.7 8.8 4.6 7.1 0.7 8.8 4.6 41 5 40 305 44.7 2.8 47.3 27.3 01/11/2006 15:20:00 6.6 0.8 8.4 4.6 6.6 0.8 8 4.6 41 6 33 305 43.9 6.7 51.8 27.3 01/11/2006 15:30:00 7 0.8 8.8 4.9 7.1 0.8 8.8 4.6 44 5 39 305 46.9 3.8 50.3 27.3 01/11/2006 15:40:00 7.1 0.5 8.4 5.3 7.1 0.6 8.4 5.7 41 5 37 305 46.8 2.2 48.4 27.3 01/11/2006 15:50:00 7 0.7 8.8 5.3 6.9 0.6 8.4 5.3 41 6 48 305 46 0 46.3 45.5 01/11/2006 16:00:00 7.6 0.8 9.1 6.1 7.4 0.8 9.1 5.7 38 4 39 305 45.9 2.3 47.7 27 01/11/2006 16:10:00 6.5 0.8 8 4.9 6.5 0.8 8 4.6 42 5 46 305 46.8 2.1 48.4 27.6 01/11/2006 16:20:00 6.7 0.6 8.4 5.3 6.7 0.7 8.4 4.9 45 5 48 305 45.5 1.8 48.1 27.3 01/11/2006 16:30:00 6.1 0.7 7.6 4.2 6.2 0.7 7.6 4.6 47 5 48 305 45 0 45.5 44.5 01/11/2006 16:40:00 6.3 0.7 7.6 4.2 6.2 0.8 7.6 4.2 39 5 39 305 45.1 0.4 46.3 43.1 01/11/2006 16:50:00 6.5 0.6 8 4.9 6.4 0.6 8 4.9 33 5 40 305 44.3 0.3 45.5 43.4 01/11/2006 17:00:00 5.9 0.7 7.6 4.2 5.8 0.7 8 4.2 32 6 33 305 44.8 0.5 45.9 38.3 01/11/2006 17:10:00 5.3 0.5 6.8 4.2 5.3 0.5 6.8 4.2 39 5 35 305 45.6 1 46.3 27.6 01/11/2006 17:20:00 5.4 0.5 6.5 4.2 5.3 0.5 6.5 4.2 35 7 47 305 46.7 0.6 47.7 45.5 01/11/2006 17:30:00 4.6 0.4 6.1 3.8 4.6 0.4 6.1 3.4 44 5 42 305 46.5 0.1 47 46.3 01/11/2006 17:40:00 5 0.7 6.8 3.8 4.9 0.7 6.8 3.8 44 7 31 305 46.1 0 46.6 45.5 01/11/2006 17:50:00 5.2 0.4 6.5 4.2 5.2 0.4 6.1 4.2 45 5 41 305 46.2 1.4 48.8 27.6 01/11/2006 18:00:00 5 0.5 6.1 3.8 5 0.5 6.5 3.4 43 7 35 305 45.9 0.4 47.3 44.5 01/11/2006 18:10:00 5 0.5 6.1 3.8 5 0.5 6.1 3.8 44 5 38 305 44.1 0.8 46.3 42.4 01/11/2006 18:20:00 5.7 0.6 6.8 4.2 5.6 0.6 6.8 3.8 38 5 40 305 44 1.2 46.6 27.3 01/11/2006 18:30:00 5.6 0.4 6.5 4.6 5.5 0.5 6.5 4.2 46 4 48 305 41.8 1.7 46.6 39.6 01/11/2006 18:40:00 5.3 0.5 6.5 4.2 5.3 0.5 6.5 3.8 42 5 50 305 47 2.5 49.2 29.2 01/11/2006 18:50:00 4.5 0.5 5.7 3.4 4.5 0.5 5.7 3.4 35 6 33 305 46 2.4 48.4 28.5 01/11/2006 19:00:00 4.7 0.4 5.7 3.8 4.6 0.5 5.7 3.4 32 4 35 305 45.3 2.9 48.1 27.6 01/11/2006 19:10:00 4.4 0.5 5.7 3 4.3 0.4 5.3 3 35 6 40 305 45.3 2.2 47.7 28.2 01/11/2006 19:20:00 4.3 0.5 5.3 3 4.3 0.5 5.3 3 34 6 41 305 46.5 1 48.1 41.3 01/11/2006 19:30:00 4.7 0.4 5.7 3.4 4.7 0.5 6.1 3.4 34 5 36 305 45.2 2.5 48.4 28.5 01/11/2006 19:40:00 5.1 0.6 6.5 3.8 5.1 0.6 6.5 3.4 35 4 36 305 45 0.5 46.3 43.1 01/11/2006 19:50:00 4.7 0.5 5.7 3.4 4.6 0.5 6.1 3.4 40 5 37 305 46.8 1.8 51.8 43.4 01/11/2006 20:00:00 4 0.5 5.3 3 3.9 0.4 4.9 3 37 5 39 305 49.3 1.8 52.5 44.5 01/11/2006 20:10:00 4.4 0.5 5.3 3 4.3 0.5 5.7 3 40 5 35 305 49.7 1 51.8 45.2 01/11/2006 20:20:00 4.1 0.5 4.9 3 4.1 0.5 5.3 3 41 6 49 305 47.6 4.7 52.9 36.2 01/11/2006 20:30:00 4.5 0.4 5.7 3.4 4.5 0.5 5.3 3 41 5 36 305 42.6 5.9 51.8 36.6 01/11/2006 20:40:00 4.8 0.4 6.1 3.8 4.7 0.4 6.1 3.8 33 5 35 305 49.6 1.4 51.8 36.6 01/11/2006 20:50:00 4.2 0.6 5.3 2.6 4.2 0.6 5.3 2.6 33 7 41 305 49.4 0.6 51.4 46.6 01/11/2006 21:00:00 4.1 0.4 4.9 3 4 0.4 4.9 3 30 5 30 305 49.2 0.7 51 45.5 01/11/2006 21:10:00 3.9 0.4 4.6 3 3.9 0.4 4.6 2.6 37 6 36 305 48.7 1 50.3 45.9 01/11/2006 21:20:00 4.1 0.5 5.3 3 4 0.5 5.3 2.6 33 7 31 305 49.3 2 52.9 35.9 01/11/2006 21:30:00 4.3 0.4 5.3 3 4.2 0.5 5.7 3 29 8 31 305 50.7 2.5 52.9 35.3 01/11/2006 21:40:00 4.8 0.4 5.7 3.4 4.7 0.5 5.7 3.4 31 5 36 305 49.7 0.2 50.3 48.8 01/11/2006 21:50:00 5.3 0.3 6.1 4.2 5.2 0.4 6.1 4.2 34 4 38 305 48.4 1.5 49.9 27.6 01/11/2006 22:00:00 4.8 0.4 5.7 3.8 4.7 0.4 5.7 3.4 37 5 35 305 47.9 0.6 49.5 44.5 01/11/2006 22:10:00 4.5 0.5 5.7 3 4.5 0.5 5.3 3 35 5 35 305 47.7 0.5 48.4 40.3 01/11/2006 22:20:00 4.4 0.4 5.3 3.4 4.3 0.4 5.3 3.4 29 6 34 305 47.5 1.9 48.8 26.7 01/11/2006 22:30:00 4.3 0.4 5.3 3.4 4.3 0.4 5.7 3.4 33 5 37 305 46.1 1.4 48.1 26.1 01/11/2006 22:40:00 4.5 0.5 5.7 3.4 4.4 0.5 5.7 3 30 7 36 305 45.7 2.6 47 26.1 01/11/2006 22:50:00 4.5 0.6 5.3 2.6 4.4 0.6 5.3 2.6 33 4 40 305 45.4 1 46.6 32 01/11/2006 23:00:00 4.1 0.4 4.9 3 4 0.4 4.9 3 26 6 35 305 46.2 2.1 48.1 26.1 01/11/2006 23:10:00 3.7 0.5 4.9 2.6 3.7 0.5 4.9 2.6 22 7 26 305 46.3 0.1 46.6 45.9 01/11/2006 23:20:00 3.9 0.5 4.9 2.6 3.9 0.5 4.9 2.6 24 6 29 305 45.7 0.9 46.6 32.3 01/11/2006 23:30:00 4.4 0.4 5.3 3.4 4.3 0.4 5.3 3 25 7 29 305 42.1 3.8 46.3 25.2 01/11/2006 23:40:00 4.3 0.4 5.3 3.4 4.2 0.5 5.3 3 25 7 17 305 45.8 3.5 51 24.9 01/11/2006 23:50:00 4.3 0.4 5.3 3.4 4.2 0.4 4.9 3.4 31 5 38 305 45.9 2.6 48.4 32.3 01/12/2006 00:00:00 4.4 0.5 5.7 3 4.3 0.5 5.3 3.4 25 6 28 305 47.3 1.1 48.8 32 01/12/2006 00:10:00 3.9 0.4 4.6 3 3.8 0.4 4.9 2.6 32 5 36 305 48.3 0.5 49.5 46.3 01/12/2006 00:20:00 3.7 0.4 4.6 2.6 3.6 0.4 4.6 2.6 48 7 32 305 48.2 1.5 49.9 32.6 01/12/2006 00:30:00 4 0.3 4.9 3 4 0.4 4.9 2.6 50 6 59 305 48.4 0.6 49.5 43.4 01/12/2006 00:40:00 4.3 0.3 4.9 3.4 4.3 0.4 4.9 3 51 4 50 305 46.9 1.4 48.4 31 01/12/2006 00:50:00 4.1 0.3 4.9 3.4 4 0.4 4.9 3 53 4 58 305 47.6 1.6 48.8 32 01/12/2006 01:00:00 4 0.4 5.3 2.6 3.9 0.5 4.9 2.6 39 7 32 305 46.5 1.1 48.4 32.6 01/12/2006 01:10:00 4.4 0.7 5.7 2.6 4.4 0.8 6.5 2.6 47 6 48 305 46.4 1.4 48.1 32 01/12/2006 01:20:00 5 0.4 6.1 4.2 4.9 0.4 6.1 3.8 51 5 60 305 47.1 0.5 48.4 44.5 01/12/2006 01:30:00 4.9 0.5 6.1 3.8 4.9 0.4 6.1 3.8 50 5 51 305 47.2 2.7 49.2 31.7 01/12/2006 01:40:00 5.1 0.4 6.1 3.8 5 0.5 6.1 3.8 51 4 57 305 47.5 0.3 48.8 45.9 01/12/2006 01:50:00 5.3 0.4 6.1 3.8 5.3 0.5 6.1 3.8 49 4 48 305 47 1.1 48.1 31.7 01/12/2006 02:00:00 5.2 0.4 6.1 4.2 5.1 0.4 6.1 3.8 48 4 52 305 46.4 2.4 48.4 31.7 01/12/2006 02:10:00 5.1 0.5 6.1 3.8 5.1 0.6 6.1 3.8 51 6 45 305 46.5 2.1 48.4 29.5 01/12/2006 02:20:00 5.5 0.5 6.5 4.2 5.5 0.6 6.5 3.8 51 5 48 305 47.5 2.1 51 30.7 01/12/2006 02:30:00 5.4 0.4 6.1 4.6 5.4 0.4 6.5 4.2 53 6 51 305 47 0.4 48.1 45.2 01/12/2006 02:40:00 5.2 0.4 6.1 4.2 5 0.5 6.5 3.4 57 5 60 305 46.3 2.6 48.8 30.1 01/12/2006 02:50:00 4.7 0.5 5.7 3.4 4.7 0.5 5.7 3.4 49 5 48 305 45.9 2.2 48.1 30.4 01/12/2006 03:00:00 4.5 0.3 5.3 3.4 4.4 0.4 5.3 3.4 49 4 48 305 47.6 2.4 49.5 32.6 01/12/2006 03:10:00 4.1 0.4 4.9 3.4 4.1 0.4 4.9 3 51 4 52 305 48.6 0.5 49.9 47 01/12/2006 03:20:00 3.6 0.4 4.6 2.3 3.5 0.5 4.6 2.3 52 5 54 305 48.7 0.6 49.9 46.6 01/12/2006 03:30:00 4.2 0.5 5.3 2.6 4.1 0.5 5.3 3 58 5 58 305 47.4 1.2 49.5 42.7 01/12/2006 03:40:00 3.7 0.5 4.9 2.3 3.6 0.6 4.9 1.9 51 8 51 305 45.9 3.1 49.5 33.6 01/12/2006 03:50:00 3.6 0.3 4.2 3 3.6 0.3 4.2 2.6 61 6 64 305 46.9 2.5 49.9 34.6 01/12/2006 04:00:00 3.3 0.4 4.2 2.3 3.1 0.4 4.6 1.9 65 9 57 305 47.4 2.8 49.9 29.8 01/12/2006 04:10:00 3.7 0.3 4.6 3 3.6 0.4 4.6 2.6 69 6 64 305 48.6 1 50.6 46.3 01/12/2006 04:20:00 3.4 0.3 4.2 2.6 3.2 0.3 3.8 2.6 69 5 67 305 49 1.2 50.6 34.9 01/12/2006 04:30:00 3.5 0.3 4.2 2.6 3.2 0.3 4.2 2.3 75 5 81 305 48.7 2.1 51 33.3 01/12/2006 04:40:00 3.7 0.5 4.9 2.6 3.5 0.4 4.6 2.6 78 9 87 305 48.4 0.4 49.5 46.3 01/12/2006 04:50:00 4.1 0.5 5.3 2.3 3.6 0.6 5.3 1.9 88 11 82 305 46.8 4.5 50.3 32.6 01/12/2006 05:00:00 4.4 0.5 5.3 3 4.2 0.6 5.3 2.6 69 8 78 305 48.7 1.1 50.3 33.3 01/12/2006 05:10:00 4.5 0.6 6.8 3 4.3 0.6 6.1 3 67 7 75 305 47.5 2.5 49.9 32 01/12/2006 05:20:00 4.2 0.4 5.3 3.4 4.1 0.4 4.9 3 63 5 61 305 47.5 0.7 48.8 38.6 01/12/2006 05:30:00 4.4 0.4 5.3 3 4.3 0.4 4.9 3 62 5 65 305 45.6 2.4 47.7 30.7 01/12/2006 05:40:00 4.2 0.4 4.9 3 4 0.5 4.9 2.6 66 4 64 305 43.9 1.2 45.5 30.4 01/12/2006 05:50:00 3.9 0.4 4.6 3 3.6 0.4 4.2 2.6 68 4 75 305 44.8 2.4 48.1 30.4 01/12/2006 06:00:00 4.2 0.2 4.9 3.4 4 0.3 4.6 3 65 3 59 305 45.6 2.6 48.1 32.3 01/12/2006 06:10:00 4 0.3 4.6 3.4 3.8 0.2 4.6 3.4 69 2 67 305 45.5 2.1 47.7 32.6 01/12/2006 06:20:00 4.1 0.3 4.9 3 3.9 0.3 4.6 2.6 64 5 65 305 37.5 6.4 47 24.3 01/12/2006 06:30:00 4 0.3 4.9 3.4 3.8 0.3 4.6 3 64 3 62 305 40.8 8.7 51.4 29.8 01/12/2006 06:40:00 3.9 0.3 4.9 3 3.6 0.4 4.9 2.6 74 5 74 305 49.3 2.7 51.4 32.3 01/12/2006 06:50:00 4.1 0.5 5.3 2.6 3.7 0.5 4.9 2.3 77 8 81 305 47.4 1.8 49.9 31 01/12/2006 07:00:00 4.2 0.7 5.7 2.3 3.8 0.7 5.3 1.9 82 8 81 305 47.8 0.6 49.2 43.8 01/12/2006 07:10:00 4.2 0.5 5.7 3 3.8 0.6 5.3 2.6 86 8 90 305 48.1 0.6 49.5 44.8 01/12/2006 07:20:00 4 0.5 5.3 2.6 3.7 0.5 4.9 2.6 79 9 74 305 47.8 0.5 49.5 45.9 01/12/2006 07:30:00 4 0.6 5.3 2.6 3.7 0.6 5.7 2.3 74 9 82 305 38.1 6.4 48.8 31.7 01/12/2006 07:40:00 3.8 0.5 4.9 2.6 3.5 0.4 4.6 2.3 78 12 75 305 38.8 4 45.9 31.4 01/12/2006 07:50:00 3.8 0.8 5.7 1.9 3.4 0.7 5.3 1.9 83 12 90 305 44.8 0.6 46.3 42.4 01/12/2006 08:00:00 2.9 0.7 4.6 1.1 2.7 0.6 4.2 1.1 87 15 81 305 43.9 3.1 46.6 31.7 01/12/2006 08:10:00 3.9 0.8 5.7 1.9 3.6 0.7 4.9 2.3 86 11 91 305 44.4 0.9 46.6 41.3 01/12/2006 08:20:00 3.2 0.6 4.6 1.1 3 0.6 4.2 1.5 87 13 96 305 44.8 0.8 46.6 42.7 01/12/2006 08:30:00 3.4 0.6 4.6 1.5 3.1 0.6 4.2 1.5 89 11 93 305 41 5.6 48.1 28.2 01/12/2006 08:40:00 3.8 0.5 4.9 2.3 3.4 0.5 4.6 2.3 90 9 93 305 46.5 2.6 49.2 32 01/12/2006 08:50:00 3.6 0.6 5.7 2.3 3.3 0.6 4.9 2.3 85 9 91 305 47.1 4.2 50.3 31.7 01/12/2006 09:00:00 3.5 1 5.7 1.5 3.3 0.9 4.9 0.4 93 11 78 305 49 0.5 50.3 47.3 01/12/2006 09:10:00 3.8 0.7 5.3 2.3 3.6 0.7 4.9 2.3 90 11 91 305 47.6 2.8 49.9 31.7 01/12/2006 09:20:00 3.4 0.6 4.6 1.9 3 0.5 4.2 1.9 98 11 80 305 46 5.2 49.9 31.7 01/12/2006 09:30:00 5 0.6 6.5 3.4 4.7 0.6 5.7 3 98 5 98 305 46.4 2.1 48.8 30.7 01/12/2006 09:40:00 4.4 0.7 6.1 1.5 4.2 0.7 5.7 2.3 104 9 92 305 46.3 1.1 49.5 43.1 01/12/2006 09:50:00 4.3 0.6 5.7 2.3 4 0.7 5.3 1.5 105 7 104 305 45.7 0.8 47.3 40 01/12/2006 10:00:00 4.6 0.8 6.1 2.6 4.4 0.7 5.7 2.6 110 8 103 305 45.4 1.8 47.3 31.7 01/12/2006 10:10:00 4.2 0.7 5.3 2.3 4 0.7 4.9 2.3 102 8 102 305 45.6 2.8 48.1 31 01/12/2006 10:20:00 5 0.5 6.1 3.8 4.6 0.5 5.7 3.4 99 4 99 305 45.4 1.9 48.1 30.7 01/12/2006 10:30:00 4.8 0.5 6.1 3 4.4 0.5 5.3 3.4 98 6 97 305 45.1 2.6 47.3 30.7 01/12/2006 10:40:00 4.6 0.6 5.7 2.6 4.3 0.5 5.3 2.6 102 8 99 305 45.1 1.6 46.6 30.7 01/12/2006 10:50:00 4.8 0.8 6.1 3 4.5 0.7 6.1 2.6 94 9 90 305 41.5 7.3 49.5 30.1 01/12/2006 11:00:00 5 0.5 6.1 3 4.6 0.5 6.1 3 86 7 75 305 44 6.4 48.8 30.4 01/12/2006 11:10:00 5.2 0.7 6.8 3.8 4.8 0.7 6.5 3.4 83 6 90 305 46.9 0.7 49.2 44.8 01/12/2006 11:20:00 5.4 0.5 7.2 3.8 5 0.5 6.8 3.8 81 6 82 305 46.3 0.3 47.3 44.5 01/12/2006 11:30:00 5 0.7 6.5 3 4.6 0.7 6.1 2.6 81 7 84 305 46.1 0.4 47.3 44.5 01/12/2006 11:40:00 5 0.6 6.1 3.4 4.7 0.5 6.1 3 75 7 82 305 46.6 0.5 47.7 45.2 01/12/2006 11:50:00 5.5 0.6 6.8 4.6 5.3 0.7 6.8 4.2 67 5 67 305 45.9 0.5 47.3 43.8 01/12/2006 12:00:00 5.6 0.6 6.8 3.8 5.3 0.6 6.8 3.4 71 6 70 305 45.5 0.4 46.6 44.1 01/12/2006 12:10:00 5.6 0.5 6.8 4.2 5.3 0.5 6.5 3.8 71 5 69 305 44.8 0.5 45.9 43.1 01/12/2006 12:20:00 5.6 0.4 6.8 4.2 5.4 0.4 6.5 4.2 69 6 70 305 43.7 2.8 47.3 30.1 01/12/2006 12:30:00 6 0.5 6.8 4.9 5.8 0.5 6.8 4.6 68 4 68 305 43.6 2.1 45.9 30.4 01/12/2006 12:40:00 6.2 0.4 6.8 4.9 6.1 0.4 6.8 4.9 66 4 62 305 43.9 2.2 46.6 30.1 01/12/2006 12:50:00 5.8 0.4 6.5 4.6 5.5 0.4 6.5 4.2 74 4 75 305 44.1 3.5 47.3 30.4 01/12/2006 13:00:00 5.1 0.4 6.1 3.8 4.8 0.4 5.7 3.4 77 5 84 305 44.9 0.5 46.3 42.7 01/12/2006 13:10:00 5.4 0.4 6.5 4.2 5.1 0.5 6.1 3.8 75 5 71 305 43.7 2.3 45.9 30.1 01/12/2006 13:20:00 5.1 0.4 6.1 3.8 4.7 0.5 5.7 3.4 77 4 77 305 43.3 3.1 46.3 30.1 01/12/2006 13:30:00 5.2 0.3 6.1 4.2 4.8 0.4 5.7 3.8 79 4 81 305 43.3 2.5 45.9 29.8 01/12/2006 13:40:00 5.1 0.4 5.7 4.2 4.7 0.3 5.3 3.8 79 4 68 305 43.2 0.5 44.5 41 01/12/2006 13:50:00 5.1 0.3 5.7 4.2 4.7 0.3 5.3 3.8 79 3 75 305 40.5 5.2 45.5 29.2 01/12/2006 14:00:00 4.7 0.5 5.7 3.4 4.3 0.5 5.3 3 82 4 81 305 43.9 3.2 46.6 29.5 01/12/2006 14:10:00 4.4 0.4 5.3 3.8 4.1 0.4 4.9 3.4 78 5 77 305 43.2 2 46.3 29.8 01/12/2006 14:20:00 5 0.5 6.1 3.8 4.9 0.5 6.1 3.4 70 5 67 305 41.1 4 44.8 28.2 01/12/2006 14:30:00 4.5 0.4 5.3 3.4 4.3 0.5 5.3 3 70 5 73 305 39.3 4.2 44.5 27 01/12/2006 14:40:00 4.6 0.2 5.3 3.8 4.4 0.2 4.9 3.8 68 3 59 305 41.8 0.8 43.8 39.6 01/12/2006 14:50:00 4.3 0.3 5.3 3.4 4.1 0.4 4.9 3.4 69 4 65 305 40.6 3.7 44.5 27.6 01/12/2006 15:00:00 3.9 0.3 4.6 3 3.6 0.4 4.6 2.3 83 6 70 305 41.2 3.7 45.9 27.3 01/12/2006 15:10:00 3.7 0.5 4.9 2.6 3.4 0.5 4.9 2.6 75 7 83 305 42.7 1.6 46.3 36.9 01/12/2006 15:20:00 3.8 0.4 4.9 3 3.6 0.4 4.6 2.6 68 6 68 305 40.2 2.6 43.1 24.9 01/12/2006 15:30:00 4.1 0.5 5.3 3 3.9 0.4 4.9 2.6 70 7 80 305 40.2 1 41.7 25.2 01/12/2006 15:40:00 4.1 0.4 4.9 3.4 3.7 0.3 4.6 3 89 5 82 305 39.4 4.5 43.4 24.6 01/12/2006 15:50:00 3.7 0.4 4.6 2.6 3.4 0.3 4.2 2.6 92 7 90 305 40.3 0.8 42.7 38.3 01/12/2006 16:00:00 4 0.4 4.9 2.6 3.7 0.4 4.6 2.6 101 5 102 305 40.2 2 42 25.2 01/12/2006 16:10:00 3.9 0.5 4.9 2.6 3.5 0.5 4.9 2.3 93 6 96 305 40.5 0.6 42 36.9 01/12/2006 16:20:00 3.6 0.4 4.6 2.6 3.3 0.4 4.2 2.3 91 8 98 305 40.6 3.7 43.8 23.4 01/12/2006 16:30:00 3.6 0.5 4.9 2.6 3.3 0.4 4.6 2.3 96 6 90 305 42.4 2.3 43.8 24.9 01/12/2006 16:40:00 4.2 0.4 5.3 3 3.8 0.4 4.6 2.6 93 5 99 305 41.9 0.4 43.1 40.3 01/12/2006 16:50:00 3.8 0.5 4.9 2.6 3.5 0.4 4.6 2.3 90 5 94 305 40 0.9 42.7 36.6 01/12/2006 17:00:00 3.9 0.4 4.9 3 3.5 0.4 4.6 2.6 85 5 85 305 37.5 1.6 40 33.9 01/12/2006 17:10:00 3.9 0.4 4.9 3 3.5 0.3 4.2 2.6 91 5 87 305 36.4 6.7 42.4 20.4 01/12/2006 17:20:00 4 0.4 4.9 3 3.6 0.4 4.2 2.6 91 4 96 305 40.5 3.2 43.1 21 01/12/2006 17:30:00 3.9 0.4 4.9 2.6 3.4 0.4 4.2 2.6 91 5 85 305 40.4 1.9 43.1 20.7 01/12/2006 17:40:00 4.1 0.4 5.3 3 3.7 0.4 4.6 2.6 87 5 94 305 40.6 0.6 42.4 38.3 01/12/2006 17:50:00 4 0.4 5.3 3 3.6 0.4 4.9 2.6 91 4 97 305 40.7 0.6 42 36.9 01/12/2006 18:00:00 3.6 0.5 4.6 2.3 3.1 0.4 4.6 2.3 91 4 92 305 40.3 0.4 41.3 38.6 01/12/2006 18:10:00 2.8 0.4 4.2 1.5 2.8 0.4 4.2 1.5 71 11 72 305 40.2 3.8 42.7 19.9 01/12/2006 18:20:00 3.8 0.7 4.9 1.9 3.4 0.7 4.6 1.9 94 9 100 305 40.8 1.8 42 20.1 01/12/2006 18:30:00 4.6 0.3 5.3 4.2 4.2 0.3 4.9 3.8 97 2 101 305 40.6 3.4 42.7 20.4 01/12/2006 18:40:00 4.3 0.3 4.9 3.4 3.9 0.3 4.6 3 104 3 99 305 41.6 1.3 43.1 21.3 01/12/2006 18:50:00 4.3 0.4 5.3 3.4 4.2 0.4 5.3 3 112 5 107 305 41.6 2.4 44.1 21.3 01/12/2006 19:00:00 4.6 0.5 6.1 3 4.6 0.5 5.7 3 116 5 118 305 42.5 0.5 44.1 40.6 01/12/2006 19:10:00 4.6 0.4 5.7 3.4 4.6 0.4 5.3 3.4 115 5 111 305 41.4 2.2 43.8 24.6 01/12/2006 19:20:00 4.6 0.4 5.7 3.4 4.4 0.4 5.7 3.4 111 4 112 305 41.9 4.2 50.6 23.7 01/12/2006 19:30:00 4.5 0.3 4.9 3.8 4.4 0.3 5.3 3.4 116 4 109 305 48.2 3.2 51 39.6 01/12/2006 19:40:00 4.1 0.5 4.9 2.6 4.3 0.5 5.3 2.3 116 7 113 305 45.5 3.7 51.4 40.6 01/12/2006 19:50:00 3.4 0.6 4.2 1.1 3.6 0.5 4.6 1.5 112 10 118 305 42.6 1.8 48.1 32.6 01/12/2006 20:00:00 3.2 0.7 4.9 1.1 3.3 0.6 4.9 1.5 113 11 127 305 43.9 2.9 51 40.3 01/12/2006 20:10:00 4 0.5 5.3 2.3 4.2 0.5 4.9 2.6 120 7 121 305 42.6 0.7 44.5 40.3 01/12/2006 20:20:00 4.5 0.6 5.3 1.9 4.7 0.5 5.7 2.6 127 6 115 305 42.5 1 44.1 32.3 01/12/2006 20:30:00 4.9 0.4 6.1 3 5 0.4 6.1 3.4 130 4 130 305 42.2 2.6 44.8 24.6 01/12/2006 20:40:00 4.9 0.3 5.7 3.8 4.9 0.4 6.1 3.8 128 3 128 305 43.8 1.6 44.8 26.1 01/12/2006 20:50:00 4.4 0.6 5.7 2.6 4.6 0.5 5.7 3 128 8 121 305 42 2.6 44.8 24 01/12/2006 21:00:00 4.7 0.3 5.3 3.4 4.8 0.3 5.7 3.8 134 3 134 305 42.5 2.8 46.6 28.8 01/12/2006 21:10:00 4.5 0.5 5.7 2.6 4.7 0.5 6.1 3.4 132 5 131 305 44.2 1.3 46.6 40.6 01/12/2006 21:20:00 4.8 0.4 5.7 3 4.9 0.4 5.7 3.4 133 4 135 305 41.8 3.1 43.4 24 01/12/2006 21:30:00 4.4 0.6 5.3 2.6 4.6 0.5 6.1 3 127 8 132 305 38.8 5.2 43.4 20.4 01/12/2006 21:40:00 4.4 0.5 5.3 3 4.8 0.5 5.7 3 125 6 118 305 43.6 4 48.4 37.6 01/12/2006 21:50:00 4.2 0.4 5.3 3 4.5 0.4 5.7 3.4 128 6 128 305 45.7 2.1 47.7 35.3 01/12/2006 22:00:00 4.8 0.4 5.7 4.2 5.1 0.3 5.7 4.2 134 3 133 305 39.2 1.5 41.3 35.9 01/12/2006 22:10:00 4.3 0.4 5.3 2.6 4.3 0.5 5.3 2.3 131 4 129 305 41.4 3.1 47.3 31.4 01/12/2006 22:20:00 4.3 0.3 4.9 3 4.3 0.3 4.9 3 128 3 126 305 45.8 1.5 48.4 39.6 01/12/2006 22:30:00 4.1 0.4 4.9 2.6 4.3 0.4 4.9 3 127 5 128 305 43.8 2.8 46.6 29.8 01/12/2006 22:40:00 4.2 0.3 5.3 3.4 4.2 0.3 4.9 3.4 127 2 125 305 44 4 47.3 28.5 01/12/2006 22:50:00 3.9 0.2 4.6 3.4 4 0.3 4.6 3 128 2 127 305 46.1 0.9 47.3 37.6 01/12/2006 23:00:00 3.6 0.5 4.6 1.9 3.7 0.6 4.6 1.5 122 8 124 305 45.1 1.9 47 32.6 01/12/2006 23:10:00 3.2 0.3 3.8 2.3 3.2 0.4 3.8 1.9 114 4 115 305 45 2.6 47.3 32 01/12/2006 23:20:00 2.7 0.3 3.8 1.9 2.6 0.3 3.4 1.9 104 7 95 305 44.8 2.1 47 30.7 01/12/2006 23:30:00 2.8 0.3 3.8 1.9 2.6 0.3 3.4 2.3 102 7 93 305 43.8 2.2 45.2 30.1 01/12/2006 23:40:00 3.2 0.3 4.2 2.3 3.2 0.2 3.8 2.6 107 5 87 305 43.9 2.8 46.3 29.5 01/12/2006 23:50:00 3.4 0.4 4.2 1.5 3.4 0.3 4.2 2.3 104 7 105 305 43.9 1.7 46.3 31 01/13/2006 00:00:00 3.3 0.2 3.8 2.6 3.2 0.3 3.8 2.3 104 5 107 305 41.2 2.7 44.1 27.3 01/13/2006 00:10:00 2.8 0.6 3.8 0.4 2.7 0.6 3.8 0.4 113 9 118 305 40.6 5 44.1 23.4 01/13/2006 00:20:00 1 0.7 3 0.4 1 0.7 3 0.4 101 32 121 305 39.4 5.2 42.7 24.9 01/13/2006 00:30:00 0.9 0.6 2.3 0.4 0.8 0.5 1.9 0.4 294 47 287 305 39.4 3.4 42.4 27.6 01/13/2006 00:40:00 0.8 0.8 3 0.4 0.8 0.7 3 0.4 171 66 119 305 37 5 40.3 20.7 01/13/2006 00:50:00 3.2 0.5 4.2 1.5 3.4 0.5 4.2 0.7 118 8 129 305 38.1 1.8 40.3 23.1 01/13/2006 01:00:00 2.9 0.5 3.8 1.9 2.7 0.6 3.8 1.5 101 15 112 305 40.3 3.7 43.4 26.4 01/13/2006 01:10:00 2.6 0.6 4.2 1.1 2.7 0.7 4.2 1.1 111 12 108 305 41.7 1.3 43.4 27.3 01/13/2006 01:20:00 2.2 0.9 3.4 0.4 2.3 0.9 3.8 0.4 93 29 116 305 40.3 2.1 41.7 27.3 01/13/2006 01:30:00 2.8 0.7 4.6 0.4 2.9 0.6 4.2 0.7 99 17 105 305 38.7 1.2 41.3 33.3 01/13/2006 01:40:00 2.4 0.7 4.2 1.1 2.5 0.6 4.6 1.1 98 14 96 305 38.8 1.8 39.6 21.9 01/13/2006 01:50:00 2.3 0.5 3.4 0.7 2.2 0.5 3.4 1.1 93 12 109 305 38.3 1.8 39.3 22.5 01/13/2006 02:00:00 2.8 0.5 4.2 1.5 2.5 0.4 3.8 1.5 90 9 105 305 39.4 1.4 42.4 35.6 01/13/2006 02:10:00 2.7 0.4 3.8 1.5 2.6 0.3 3.4 1.5 89 12 92 305 38.4 3.5 41.3 22.8 01/13/2006 02:20:00 2.3 0.5 3.4 1.1 2.2 0.4 3 1.1 75 15 81 305 39.4 1.1 41.7 36.2 01/13/2006 02:30:00 1.8 0.6 3.4 0.4 1.8 0.6 3.4 0.4 62 9 63 305 39.5 2.2 41.7 25.2 01/13/2006 02:40:00 2.9 0.4 3.8 1.9 2.7 0.3 3.4 1.9 72 8 75 305 40.7 1.2 43.1 36.9 01/13/2006 02:50:00 2.8 0.3 3.8 2.3 2.7 0.3 3.4 2.3 78 6 80 305 39.6 2.8 42.7 25.5 01/13/2006 03:00:00 2.9 0.4 4.2 2.3 2.8 0.3 3.4 1.9 83 5 82 305 39.8 1.4 42.4 35.3 01/13/2006 03:10:00 2.7 0.2 3.4 1.9 2.6 0.2 3 1.9 83 5 78 305 38.3 3.8 43.1 22.5 01/13/2006 03:20:00 2.2 0.4 3 1.5 2.2 0.3 3 1.5 79 6 80 305 36.4 4 40 21.6 01/13/2006 03:30:00 2 0.3 2.6 1.1 2 0.2 2.6 1.5 75 6 70 305 36.3 2.2 41 23.4 01/13/2006 03:40:00 1.7 0.2 2.3 1.1 1.7 0.3 2.3 1.1 68 6 65 305 36.3 1.9 39.3 21.9 01/13/2006 03:50:00 1.6 0.3 2.3 0.7 1.7 0.3 2.3 1.1 54 5 55 305 36.4 3.5 40.3 22.5 01/13/2006 04:00:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 48 5 43 305 35.7 3.5 39.6 20.7 01/13/2006 04:10:00 0.9 0.4 1.9 0.4 0.9 0.5 1.9 0.4 35 24 45 305 36.4 3.8 39.6 21.6 01/13/2006 04:20:00 1 0.5 2.3 0.4 1.3 0.4 1.9 0.4 201 15 212 305 36.7 1.5 39.3 26.4 01/13/2006 04:30:00 0.6 0.4 1.5 0.4 0.7 0.4 1.5 0.4 210 13 221 305 36.2 0.5 37.2 31.4 01/13/2006 04:40:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 206 8 201 305 35.4 3.5 37.9 20.7 01/13/2006 04:50:00 0.5 0.2 1.5 0.4 0.9 0.4 1.9 0.4 206 5 212 305 35.2 2.8 37.9 20.4 01/13/2006 05:00:00 0.5 0.2 1.5 0.4 0.8 0.4 1.5 0.4 190 17 196 305 35.1 4.4 39.6 21 01/13/2006 05:10:00 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 177 2 305 305 37.7 3.2 40.3 23.1 01/13/2006 05:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 98 94 303 305 37.9 1.8 40.3 23.1 01/13/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 324 13 305 305 37.9 0.5 39.3 36.2 01/13/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 333 0 305 305 40 2 42 23.4 01/13/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 333 0 305 305 39.4 3.4 41.3 22.2 01/13/2006 06:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 11 41 56 305 39.8 0.9 41.3 32 01/13/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 56 0 305 305 38.8 5 42.7 21.9 01/13/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 56 0 305 305 41.2 0.9 43.1 37.9 01/13/2006 06:30:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 54 8 48 305 41.9 0.6 43.1 36.9 01/13/2006 06:40:00 1.7 0.6 3.4 0.4 1.6 0.6 3 0.4 54 17 33 305 41.7 0.2 42.7 41 01/13/2006 06:50:00 2.3 0.4 3.4 1.1 2.2 0.4 3.4 1.1 44 9 42 305 41.8 0.1 42.7 40.6 01/13/2006 07:00:00 2.8 0.4 3.8 2.3 2.8 0.3 3.8 1.9 48 6 36 305 41 0.4 42 39.6 01/13/2006 07:10:00 3.3 0.3 4.2 2.6 3.3 0.3 3.8 2.6 44 6 43 305 29.9 8.3 42.4 22.8 01/13/2006 07:20:00 3.5 0.5 4.9 2.6 3.3 0.5 4.9 2.3 26 10 18 305 24.9 0.4 26.4 24.3 01/13/2006 07:30:00 3.9 0.5 4.9 2.6 3.7 0.5 4.9 2.6 24 9 18 305 25.5 0.7 26.7 24 01/13/2006 07:40:00 3.9 0.4 4.9 3 3.6 0.5 4.9 2.6 36 4 30 305 40.6 9.5 47.3 25.5 01/13/2006 07:50:00 3.8 0.4 4.9 3 3.6 0.4 4.9 2.6 31 6 22 305 46.5 0.2 47.7 44.8 01/13/2006 08:00:00 3.8 0.5 4.9 2.6 3.7 0.5 4.9 2.3 20 5 13 305 46.1 0.7 47.3 43.4 01/13/2006 08:10:00 3.9 0.5 5.3 3 3.8 0.5 4.9 2.6 16 5 12 305 45.2 0.6 46.3 42 01/13/2006 08:20:00 4.4 0.5 5.3 3 4.4 0.4 5.3 3.4 19 3 19 305 44.1 1.6 45.5 22.8 01/13/2006 08:30:00 3.9 0.5 4.9 2.6 3.9 0.5 4.9 3 20 5 23 305 42.9 3.5 45.5 29.5 01/13/2006 08:40:00 4.5 0.4 5.7 3.4 4.4 0.4 5.3 3.4 23 4 31 305 43.2 0.5 44.1 40.3 01/13/2006 08:50:00 4.1 0.5 5.3 3 3.9 0.5 5.3 3 26 5 32 305 32.9 6.2 44.5 21.6 01/13/2006 09:00:00 4.4 0.5 5.7 3.4 4.2 0.5 5.7 3.4 31 5 32 305 38.4 6.7 44.5 24 01/13/2006 09:10:00 3.5 0.3 4.6 3 3.4 0.3 4.2 2.6 33 4 35 305 32.6 8 44.5 24.6 01/13/2006 09:20:00 3.1 0.4 4.6 2.3 3 0.4 4.2 2.3 28 6 27 305 41.8 2.4 44.1 23.7 01/13/2006 09:30:00 3 0.5 4.2 1.9 2.9 0.4 4.2 1.9 17 6 5 305 37.6 8 44.1 -16.6 01/13/2006 09:40:00 3.4 0.3 4.2 2.6 3.2 0.3 4.2 2.6 11 4 10 305 38.8 6.4 42.4 -19.5 01/13/2006 09:50:00 3.1 0.3 4.2 2.3 3 0.3 3.8 2.3 12 5 17 305 40 2.4 42 26.1 01/13/2006 10:00:00 3.5 0.5 4.6 2.6 3.3 0.5 4.6 2.3 11 6 9 305 37.4 5.6 42.4 26.4 01/13/2006 10:10:00 3.9 0.4 4.9 3 3.8 0.4 4.6 3 8 3 11 305 37.9 8 43.8 21.9 01/13/2006 10:20:00 3.7 0.4 4.2 2.3 3.6 0.4 4.6 2.3 14 5 9 305 34.6 9.5 43.8 21.6 01/13/2006 10:30:00 3.3 0.4 4.2 2.3 3.2 0.3 4.2 2.3 21 5 28 305 38.6 6.2 42.7 21.3 01/13/2006 10:40:00 2.5 0.3 3.4 1.5 2.4 0.3 3 1.5 28 6 21 305 38.8 5.6 42.4 17.3 01/13/2006 10:50:00 3.1 0.5 4.2 1.9 2.9 0.5 4.2 1.9 17 5 13 305 39.1 1.1 40.6 36.6 01/13/2006 11:00:00 3.4 0.3 4.2 2.6 3.3 0.3 4.2 2.3 15 5 18 305 37.5 6.4 41 17.6 01/13/2006 11:10:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.6 10 4 11 305 36.5 7 41.7 18.7 01/13/2006 11:20:00 3.6 0.4 4.2 2.6 3.5 0.4 4.6 2.6 15 5 5 305 37.7 5.2 40.6 20.1 01/13/2006 11:30:00 3.5 0.4 4.2 2.6 3.4 0.4 4.2 2.6 14 3 6 305 38.9 0.2 39.6 37.9 01/13/2006 11:40:00 3.5 0.4 4.6 2.3 3.4 0.4 4.2 2.3 19 4 22 305 38.3 0.5 39.3 36.9 01/13/2006 11:50:00 4.1 0.4 4.9 3 3.9 0.4 4.6 2.6 24 5 31 305 37.5 0.3 38.3 36.6 01/13/2006 12:00:00 4.4 0.3 4.9 3 4.3 0.3 5.3 3.4 20 5 25 305 35.8 6.2 39.6 17.3 01/13/2006 12:10:00 4.1 0.4 4.9 3 4 0.4 4.6 3 20 4 24 305 39 0.3 39.6 37.6 01/13/2006 12:20:00 3.8 0.4 4.6 2.6 3.7 0.4 4.6 2.6 25 6 17 305 36.9 7.3 42.7 17.9 01/13/2006 12:30:00 3.8 0.4 4.9 3 3.7 0.4 4.6 2.6 27 7 21 305 38.3 3.7 41 18.4 01/13/2006 12:40:00 3.7 0.4 4.9 3 3.7 0.4 4.6 2.6 22 4 25 305 36 7 40.6 17 01/13/2006 12:50:00 4.2 0.5 4.9 3 4.1 0.5 4.9 3 14 4 16 305 30.7 10.4 40.6 -18.4 01/13/2006 13:00:00 4.6 0.4 5.7 3 4.5 0.5 5.7 3 8 6 10 305 36.3 6.7 40.6 21 01/13/2006 13:10:00 4.5 0.4 5.7 3.4 4.5 0.4 5.7 3.4 9 4 5 305 36.7 0.6 38.3 33.9 01/13/2006 13:20:00 4.7 0.5 5.7 3.8 4.6 0.5 6.1 3.4 9 4 7 305 35.7 5.9 39.6 17.9 01/13/2006 13:30:00 4.5 0.4 5.7 3.4 4.4 0.4 5.3 3.4 9 5 12 305 19.3 4.5 37.9 17.3 01/13/2006 13:40:00 4.3 0.5 5.7 3 4.3 0.5 6.1 3.4 12 4 5 305 29 10.8 40.3 16.5 01/13/2006 13:50:00 4.2 0.5 5.3 2.6 4.1 0.5 5.3 2.6 13 5 15 305 39.4 0 39.6 39.3 01/13/2006 14:00:00 4.9 0.6 6.1 3.4 4.8 0.6 6.1 3 11 5 11 305 38.8 0.3 39.6 37.2 01/13/2006 14:10:00 4.7 0.5 6.1 3.4 4.6 0.5 5.7 3.4 21 6 26 305 34.8 5.4 37.6 14.8 01/13/2006 14:20:00 4.7 0.5 6.1 3.4 4.5 0.5 5.7 3 19 8 9 305 34.6 4 36.6 15.3 01/13/2006 14:30:00 3.9 0.5 5.3 3 3.7 0.5 4.9 2.6 18 7 21 305 34.3 5.9 37.9 15.6 01/13/2006 14:40:00 3.9 0.5 5.3 3 3.8 0.4 5.7 2.6 10 4 3 305 36.3 0.2 37.2 35.3 01/13/2006 14:50:00 4.3 0.4 5.3 3.4 4.1 0.4 5.7 3 14 5 14 305 33.4 7 37.2 14.3 01/13/2006 15:00:00 4.6 0.8 6.5 3 4.5 0.8 6.5 2.6 16 9 9 305 34.8 5.6 38.6 15.3 01/13/2006 15:10:00 5.4 0.6 6.8 3.8 5.4 0.6 6.8 3.8 5 6 2 305 28.6 11.8 36.6 -18.4 01/13/2006 15:20:00 5.3 0.7 6.8 3.4 5.3 0.7 6.8 3.4 4 6 6 305 24.4 1 27 22.2 01/13/2006 15:30:00 5.6 0.8 7.6 3.8 5.5 0.8 7.2 3.8 8 7 11 305 30.9 2.5 33.6 22.2 01/13/2006 15:40:00 5.9 0.6 7.2 4.2 5.9 0.7 7.6 4.6 10 6 10 305 31.1 1.3 33.3 26.1 01/13/2006 15:50:00 6 0.7 8 4.2 5.9 0.7 8 4.2 8 5 14 305 30.7 6.7 34.9 7.7 01/13/2006 16:00:00 5.8 0.9 8.4 4.2 5.8 0.9 8.4 4.2 19 8 12 305 31.4 5.2 34.3 6.4 01/13/2006 16:10:00 5.7 0.8 7.6 3.8 5.5 0.9 7.6 3.4 22 7 36 305 33.1 8 38.9 7.7 01/13/2006 16:20:00 5.4 0.7 7.6 4.2 5.2 0.7 7.6 3.4 26 7 27 305 33.3 1 36.6 29.8 01/13/2006 16:30:00 5.5 0.7 7.2 3.8 5.4 0.7 7.2 3.8 19 9 9 305 30.4 7.3 35.3 9.2 01/13/2006 16:40:00 5.6 1 8 3.4 5.5 0.9 7.6 3.8 33 6 41 305 32.3 2.5 37.9 27.9 01/13/2006 16:50:00 5.9 0.8 7.6 4.2 5.8 0.8 7.2 4.2 32 5 32 305 35.6 4.2 43.4 10.8 01/13/2006 17:00:00 5.9 0.5 7.2 4.6 5.8 0.6 7.2 4.6 33 5 32 305 42.2 0.2 43.1 41.3 01/13/2006 17:10:00 6.1 0.5 7.2 4.6 5.9 0.5 6.8 4.6 34 5 34 305 40.6 4 42.7 25.5 01/13/2006 17:20:00 6 0.6 7.2 4.6 5.7 0.7 7.2 4.2 32 6 33 305 38.8 4.4 42 26.7 01/13/2006 17:30:00 6 0.5 7.6 4.6 5.8 0.5 7.2 4.2 27 4 27 305 38.5 0.2 39.3 37.6 01/13/2006 17:40:00 5.6 0.8 6.8 3.8 5.5 0.8 7.2 3.8 20 5 27 305 37.4 1.8 38.9 21 01/13/2006 17:50:00 5.5 0.6 6.8 4.2 5.2 0.6 6.8 3.8 16 5 10 305 39.1 0.4 40 37.9 01/13/2006 18:00:00 6 0.6 7.2 4.2 5.8 0.6 7.2 4.2 21 5 18 305 38.9 0.3 40 37.9 01/13/2006 18:10:00 5.7 0.8 7.2 3.8 5.6 0.8 7.2 3.8 22 6 19 305 38.2 0.4 38.9 36.9 01/13/2006 18:20:00 5.8 0.7 7.2 3.8 5.7 0.7 7.2 3.8 19 5 17 305 37 0.6 38.3 35.9 01/13/2006 18:30:00 5.4 0.8 7.2 3.8 5.1 0.8 7.2 3.8 30 9 24 305 34.7 6.4 41 20.4 01/13/2006 18:40:00 5.3 0.4 6.5 4.2 5 0.4 6.1 4.2 39 4 44 305 39.2 0.4 40 36.9 01/13/2006 18:50:00 6.5 0.5 7.6 5.3 6.2 0.6 7.2 4.9 39 4 39 305 37.5 1.2 39.3 27 01/13/2006 19:00:00 7 0.6 8.4 5.7 6.8 0.6 8 4.9 34 4 30 305 37.1 0.6 38.3 34.6 01/13/2006 19:10:00 7.1 0.6 8.4 5.3 6.8 0.5 8 4.9 32 5 30 305 36.4 0.8 37.2 33 01/13/2006 19:20:00 6.5 0.6 8 5.3 6.3 0.6 8 4.9 33 4 36 305 35.5 5.2 39.3 19.3 01/13/2006 19:30:00 6.4 0.6 8 4.6 6.1 0.6 7.6 4.6 33 5 29 305 37.7 0.2 38.9 36.9 01/13/2006 19:40:00 6.1 0.6 7.2 4.6 5.8 0.5 7.2 4.2 33 4 37 305 36.3 0.5 37.9 33.9 01/13/2006 19:50:00 6.3 0.6 7.6 4.9 6 0.6 7.2 4.2 34 5 29 305 36.1 0.2 36.9 34.3 01/13/2006 20:00:00 6.4 0.5 7.6 4.9 6.1 0.5 7.2 4.6 36 4 23 305 36.7 0.6 37.6 35.3 01/13/2006 20:10:00 6.3 0.4 7.2 5.3 6 0.5 7.6 4.9 34 4 39 305 36.7 0.1 37.6 36.6 01/13/2006 20:20:00 6.4 0.5 7.6 4.9 6 0.6 7.2 4.6 34 4 38 305 36.1 3.2 37.9 21.9 01/13/2006 20:30:00 5.8 0.6 7.6 4.6 5.5 0.5 6.8 4.2 33 6 30 305 36.8 0.2 37.6 36.2 01/13/2006 20:40:00 5.9 0.6 8 4.6 5.7 0.6 7.6 4.6 31 6 25 305 37.3 0 37.6 36.9 01/13/2006 20:50:00 5.8 0.6 7.6 4.6 5.5 0.5 7.6 4.2 32 5 24 305 36.9 1.8 37.9 22.5 01/13/2006 21:00:00 6.2 0.4 7.2 4.9 5.8 0.5 7.2 4.6 36 4 36 305 35.5 0.5 36.9 34.6 01/13/2006 21:10:00 6.6 0.5 7.6 4.9 6.3 0.4 7.2 4.9 37 5 37 305 21.8 5.2 35.9 17.9 01/13/2006 21:20:00 7.2 0.5 8.4 5.7 6.8 0.6 8.4 5.3 36 4 39 305 40.2 4.7 42.4 20.1 01/13/2006 21:30:00 7.2 0.5 8.4 5.7 6.9 0.5 8.4 5.7 37 4 35 305 40.6 0.8 42 35.9 01/13/2006 21:40:00 7.1 0.4 8.4 6.1 6.8 0.5 8.4 5.7 39 4 40 305 39.7 0.5 40.6 36.2 01/13/2006 21:50:00 6.9 0.5 8.4 5.3 6.7 0.6 8.4 4.9 39 4 35 305 37.5 5.6 40 20.7 01/13/2006 22:00:00 6.7 0.5 8.4 5.7 6.5 0.5 8 4.9 36 4 38 305 38.3 0.4 39.3 35.3 01/13/2006 22:10:00 6.4 0.5 8 4.9 6.3 0.6 7.6 4.9 42 5 41 305 38.2 0.9 38.6 23.7 01/13/2006 22:20:00 6.5 0.5 8 5.3 6.4 0.5 8 5.3 39 5 39 305 38.4 0.8 40 30.4 01/13/2006 22:30:00 6.5 0.7 8 4.9 6.3 0.7 8.4 4.9 45 4 46 305 23.1 6.4 38.9 19.3 01/13/2006 22:40:00 6.6 0.6 8.4 4.9 6.4 0.6 8 4.9 43 5 49 305 43.1 1 44.8 40 01/13/2006 22:50:00 6.2 0.5 7.2 4.9 6 0.6 7.6 4.9 39 5 56 305 39.7 1.8 41.7 19.9 01/13/2006 23:00:00 6.9 0.9 8.4 4.6 6.7 0.9 9.1 4.6 33 5 32 305 37.7 0.4 38.6 35.9 01/13/2006 23:10:00 7.4 0.5 8.8 5.7 7.3 0.5 8.8 5.7 36 5 38 305 37.7 0.5 38.6 35.9 01/13/2006 23:20:00 7.3 0.5 8.8 5.7 7 0.6 8.4 5.3 36 5 34 305 30.4 9.9 43.1 18.4 01/13/2006 23:30:00 7.2 0.6 8.8 5.7 6.9 0.6 8.4 5.7 36 4 42 305 40.8 1.3 42.7 26.4 01/13/2006 23:40:00 6.7 0.5 8 5.3 6.5 0.5 8 5.3 36 4 40 305 37.9 2.1 40 22.5 01/13/2006 23:50:00 7.1 0.5 8.4 5.3 6.8 0.6 8.8 5.3 36 4 37 305 36.8 1.5 38.9 24.9 01/14/2006 00:00:00 7.2 0.5 8.4 5.7 6.9 0.5 8 5.7 38 4 36 305 38 4.2 41 19.3 01/14/2006 00:10:00 6.9 0.5 8 5.3 6.8 0.6 8.4 4.9 37 5 43 305 20.5 2.4 39.3 17.9 01/14/2006 00:20:00 7.1 0.5 8.4 5.7 6.9 0.6 8.4 5.3 36 4 35 305 20.6 0 21.3 19.6 01/14/2006 00:30:00 6.6 0.5 8 4.9 6.5 0.6 8 4.9 34 5 40 305 25.8 9.9 45.9 20.4 01/14/2006 00:40:00 6.8 0.5 8 5.3 6.6 0.5 7.6 5.3 36 4 37 305 45.4 0.7 47 42.7 01/14/2006 00:50:00 6.4 0.5 7.6 5.3 6.3 0.5 7.6 4.9 37 5 37 305 43.3 1.8 46.3 20.7 01/14/2006 01:00:00 5.8 0.6 7.2 4.2 5.6 0.6 7.2 4.2 38 4 38 305 41.8 2.3 43.8 19.9 01/14/2006 01:10:00 5.3 0.5 6.8 3.8 5.1 0.5 6.5 3.8 42 6 36 305 40.6 1.8 42.4 21.6 01/14/2006 01:20:00 5.2 0.4 6.5 4.2 5 0.4 5.7 4.2 45 5 37 305 41 3.1 43.8 21.3 01/14/2006 01:30:00 4.8 0.5 6.1 3.8 4.5 0.5 5.7 3.4 35 6 23 305 29.9 9.9 43.8 21.3 01/14/2006 01:40:00 4.6 0.4 5.7 3.4 4.4 0.4 5.7 3.8 31 6 35 305 43.8 0.6 44.8 42 01/14/2006 01:50:00 5.1 0.6 6.8 3.8 4.8 0.6 6.5 3.4 32 5 26 305 41.2 4.7 43.8 22.2 01/14/2006 02:00:00 4.2 0.5 5.7 3.4 4.1 0.5 5.3 3 36 5 26 305 41.8 0.8 43.4 40 01/14/2006 02:10:00 4.5 0.5 5.7 3.4 4.1 0.5 6.1 3 34 7 39 305 40.2 5.6 44.8 22.2 01/14/2006 02:20:00 4.4 0.4 5.3 3.4 4.1 0.3 5.3 3.4 35 5 30 305 36 8.7 44.1 21.9 01/14/2006 02:30:00 5.2 0.6 6.5 4.2 4.7 0.6 6.1 3.4 33 5 23 305 21.9 0.3 22.8 20.7 01/14/2006 02:40:00 4.7 0.5 6.1 3.8 4.4 0.4 5.3 3.8 36 6 31 305 42 9.9 48.1 21.3 01/14/2006 02:50:00 5 0.4 6.1 4.2 4.9 0.4 6.1 3.8 38 4 32 305 45.5 1 46.3 39.6 01/14/2006 03:00:00 5.2 0.4 6.1 4.2 5 0.4 6.1 3.4 39 4 40 305 36.4 11.3 47.7 21.9 01/14/2006 03:10:00 5 0.6 7.2 3.8 4.8 0.6 6.8 3.4 33 5 26 305 46.2 0.5 47.3 40.3 01/14/2006 03:20:00 5.3 0.5 6.8 4.2 5.2 0.6 6.5 3.8 37 6 35 305 44.7 2.4 46.3 21.9 01/14/2006 03:30:00 5.1 0.6 6.5 3.4 5 0.6 6.1 3.4 37 6 30 305 42.2 4.7 45.2 21.3 01/14/2006 03:40:00 5.7 0.6 7.2 4.2 5.5 0.5 6.8 4.2 37 5 48 305 41.7 2.2 44.5 20.4 01/14/2006 03:50:00 5.4 0.5 6.8 3.8 5.1 0.5 6.5 3.8 32 5 29 305 34.3 9.9 43.4 21 01/14/2006 04:00:00 5.8 0.4 7.2 4.6 5.6 0.4 6.8 4.6 33 4 35 305 43.7 6.2 46.6 21.9 01/14/2006 04:10:00 5.8 0.5 6.8 4.2 5.5 0.5 6.8 4.2 35 5 38 305 32.4 11.8 44.8 19.6 01/14/2006 04:20:00 5.2 0.6 6.8 3.8 5 0.6 6.5 3.8 33 5 35 305 39.2 9.5 44.5 18.1 01/14/2006 04:30:00 5.8 0.7 7.6 3.8 5.5 0.6 7.2 3.8 31 5 28 305 38.1 9.9 44.5 17.9 01/14/2006 04:40:00 5.8 0.6 7.2 4.2 5.5 0.6 6.8 4.2 32 5 33 305 42 0.6 43.1 38.6 01/14/2006 04:50:00 5.1 0.4 6.1 3.8 4.9 0.5 6.1 3.8 36 4 36 305 33.4 11.8 44.5 13.7 01/14/2006 05:00:00 4.9 0.5 6.5 3.8 4.8 0.5 6.5 3.8 38 6 38 305 40.3 1.5 42.7 19.3 01/14/2006 05:10:00 5 0.6 6.5 3.8 4.9 0.6 6.8 3.4 41 6 32 305 38.8 2.1 41 17.9 01/14/2006 05:20:00 5.4 0.6 6.8 3.8 5.2 0.6 6.5 4.2 45 6 43 305 36.8 5.6 40.3 15.6 01/14/2006 05:30:00 5.7 0.6 7.2 4.2 5.6 0.8 7.6 3.8 46 5 55 305 37 5 39.6 14.8 01/14/2006 05:40:00 5.9 0.5 6.8 4.6 5.7 0.6 7.2 4.2 45 5 42 305 34.1 9.1 40.6 15.3 01/14/2006 05:50:00 5.2 0.5 6.8 4.2 5.1 0.6 6.5 3.8 45 5 46 305 35.9 6.7 40 15.1 01/14/2006 06:00:00 5.6 0.6 6.8 4.2 5.5 0.6 6.8 4.2 41 5 43 305 35 7 40.3 17.9 01/14/2006 06:10:00 5.1 0.6 6.5 3.8 4.9 0.6 6.5 3.4 39 5 38 305 21.4 0.2 21.9 20.4 01/14/2006 06:20:00 5.1 0.4 6.5 3.8 5 0.5 6.1 3.8 34 6 23 305 35.3 9.1 42.4 21.3 01/14/2006 06:30:00 5 0.7 6.5 3.4 5 0.7 6.8 3.4 31 6 35 305 39.7 1.4 41.3 35.9 01/14/2006 06:40:00 5.6 0.6 7.2 4.2 5.5 0.6 7.2 4.2 38 6 33 305 31.8 7 39.3 14.3 01/14/2006 06:50:00 5.9 0.7 7.6 4.2 6 0.7 8 4.2 30 11 36 305 23.4 8.3 39.3 14.8 01/14/2006 07:00:00 6.4 0.7 8.4 4.9 6.4 0.7 8.4 4.9 25 7 30 305 35.7 2 38.3 32.6 01/14/2006 07:10:00 6.2 0.8 8 4.6 6.1 0.8 8 4.2 30 6 41 305 32.6 3.4 34.3 14.8 01/14/2006 07:20:00 6 0.8 7.6 4.2 5.9 0.7 7.6 4.2 29 8 41 305 32.1 2.6 33.6 15.6 01/14/2006 07:30:00 5.5 0.8 7.2 3.8 5.6 0.8 7.6 3.8 35 8 43 305 36.6 0.2 37.2 35.9 01/14/2006 07:40:00 6.3 0.9 8.8 4.6 6.2 0.9 8.8 4.2 30 7 32 305 35.2 5.6 39.3 17.9 01/14/2006 07:50:00 6 0.6 8 4.6 5.9 0.6 8 4.6 34 6 27 305 33.6 7.3 41.3 21.6 01/14/2006 08:00:00 5.9 0.7 8.4 4.2 5.7 0.7 8.4 4.2 32 9 21 305 37.4 2.9 40 21.6 01/14/2006 08:10:00 6 0.8 8 3.8 5.9 0.8 7.6 3.8 39 9 48 305 38.8 2.8 40.6 24.9 01/14/2006 08:20:00 7 1 9.5 4.9 6.8 1 8.8 4.9 26 6 19 305 25.2 4.4 38.9 23.1 01/14/2006 08:30:00 6.6 1 9.9 4.2 6.4 1 9.5 4.2 35 10 39 305 23.7 0.2 24.6 23.1 01/14/2006 08:40:00 7.5 1 9.1 5.3 7.4 1 9.5 4.9 36 9 30 305 38.6 8 44.1 23.7 01/14/2006 08:50:00 7.8 0.8 9.9 5.7 7.7 0.9 10.3 5.3 34 10 37 305 41.7 0.6 43.1 40.3 01/14/2006 09:00:00 7.1 0.9 9.5 4.6 7 1 9.9 4.6 34 10 26 305 41 0.6 42.4 38.3 01/14/2006 09:10:00 7.7 0.9 9.9 4.6 7.6 1 9.9 5.3 34 11 46 305 38.5 6.2 42.4 23.7 01/14/2006 09:20:00 7.7 0.9 9.9 5.7 7.6 0.9 9.9 5.3 40 7 49 305 34.4 9.9 45.2 23.7 01/14/2006 09:30:00 7.2 0.8 9.5 5.3 7 0.8 9.5 4.9 32 7 29 305 41.7 5.4 44.8 24.6 01/14/2006 09:40:00 8.1 1.1 11.5 5.3 7.9 1.2 11.5 4.9 29 7 38 305 40.6 6.2 44.5 24.3 01/14/2006 09:50:00 9 0.9 11.1 6.8 8.9 0.9 11.5 6.1 37 6 32 305 42.7 1.3 44.8 40.3 01/14/2006 10:00:00 8.8 1 10.7 6.5 8.6 1 11.1 6.1 32 8 38 305 39.9 6.4 45.5 24 01/14/2006 10:10:00 8.9 1 11.1 6.1 8.7 1 11.1 6.1 35 6 37 305 40.9 2.6 44.5 24 01/14/2006 10:20:00 9 1 11.5 6.5 8.8 1.1 11.8 6.5 24 5 16 305 39.2 6.2 43.1 24 01/14/2006 10:30:00 7.8 0.9 9.5 5.7 7.7 0.9 9.9 5.3 29 7 25 305 42.5 0.2 43.1 40.6 01/14/2006 10:40:00 8.1 1 9.9 5.7 8 0.9 9.9 6.1 24 6 21 305 41.3 5.4 44.5 23.4 01/14/2006 10:50:00 9 0.8 11.5 6.8 8.8 1 11.5 6.1 25 7 10 305 34.5 9.9 44.5 19.9 01/14/2006 11:00:00 8.5 1.2 11.8 5.7 8.4 1.2 11.5 5.7 30 7 25 305 44.2 1 46.3 41.3 01/14/2006 11:10:00 9.2 1.2 11.5 6.5 9.1 1.2 11.8 6.1 19 6 13 305 41.2 4.5 44.5 19.6 01/14/2006 11:20:00 9.2 0.9 11.5 7.2 9 1 11.5 6.5 21 6 25 305 41.8 0.3 42.4 39.3 01/14/2006 11:30:00 8.6 0.7 10.3 6.5 8.4 0.7 9.9 6.8 28 8 24 305 31.3 8.7 41.3 18.1 01/14/2006 11:40:00 8.7 1 11.1 6.5 8.5 1 10.7 6.1 29 10 22 305 31.4 0.6 32.3 29.2 01/14/2006 11:50:00 9.5 0.8 11.1 7.2 9.3 0.8 11.1 6.5 28 7 31 305 40.4 7 47 29.5 01/14/2006 12:00:00 8.6 1 11.5 6.5 8.4 1.1 11.5 6.5 27 8 33 305 45.9 1 47.3 31.7 01/14/2006 12:10:00 8.8 1 11.1 6.5 8.6 1 11.1 6.5 33 6 33 305 44.1 1.4 46.6 31 01/14/2006 12:20:00 8.5 1 10.7 6.1 8.2 1 10.7 5.7 35 6 25 305 43.1 0.7 44.8 39.3 01/14/2006 12:30:00 9.6 0.8 11.5 7.6 9.3 0.9 11.5 7.2 29 7 31 305 42.1 0.8 43.1 34.3 01/14/2006 12:40:00 9.4 0.8 11.8 7.2 9.3 0.8 11.1 7.2 28 8 17 305 41.8 1.6 43.4 27.3 01/14/2006 12:50:00 8.4 0.9 11.1 6.1 8.3 0.9 10.7 6.1 34 5 30 305 28.5 4.7 41.3 21.6 01/14/2006 13:00:00 7 0.8 9.5 5.3 6.7 0.9 9.5 4.9 37 8 42 305 30.9 7.3 47 3.2 01/14/2006 13:10:00 8 0.8 10.3 6.1 7.8 0.8 9.5 6.1 34 6 28 305 45.2 1.5 47 36.6 01/14/2006 13:20:00 8.5 1.1 11.1 5.7 8.3 1.1 10.3 5.3 36 6 37 305 37.7 8 44.5 26.4 01/14/2006 13:30:00 8.6 1.1 11.1 6.1 8.4 1.1 10.7 5.7 36 6 41 305 37.2 8.7 47 26.4 01/14/2006 13:40:00 8 0.8 9.9 6.1 7.8 0.9 10.3 6.1 26 8 29 305 43.7 3.4 46.6 24 01/14/2006 13:50:00 8.6 1.3 11.1 5.7 8.5 1.3 11.1 5.3 16 6 17 305 40.8 6.2 46.3 28.5 01/14/2006 14:00:00 8.4 1 11.1 5.7 8.3 1.1 11.5 5.3 19 6 19 305 30.5 11.8 44.8 0.1 01/14/2006 14:10:00 8.8 1.2 11.5 5.3 8.6 1.3 10.7 5.3 25 5 30 305 41.2 2.3 45.2 16.2 01/14/2006 14:20:00 9.5 1 11.8 7.2 9.3 1.1 11.8 6.1 24 5 21 305 38.6 4.2 49.5 14 01/14/2006 14:30:00 9.1 1.2 11.8 6.5 8.9 1.2 11.8 6.1 33 7 22 305 31.3 1.3 35.9 28.5 01/14/2006 14:40:00 8.3 0.9 11.1 6.1 8 1 11.1 5.7 29 6 19 305 43.9 9.1 52.5 27 01/14/2006 14:50:00 9 1.2 12.6 6.5 9 1.2 12.2 6.5 19 7 17 305 32.7 17.4 51.8 -6.9 01/14/2006 15:00:00 9.2 1 11.8 6.8 9 1 11.5 6.8 31 8 32 305 47.3 0.4 48.4 44.8 01/14/2006 15:10:00 9.3 1.2 12.2 6.5 9.1 1.1 11.8 6.5 31 8 29 305 38.7 7 47.7 21 01/14/2006 15:20:00 9.2 1.1 11.8 6.8 8.9 1.1 11.8 6.8 33 6 32 305 43.2 8.3 52.9 35.3 01/14/2006 15:30:00 10 1.1 12.2 6.8 9.8 1.2 12.2 6.8 28 7 21 305 49.6 6.7 52.9 33.6 01/14/2006 15:40:00 9.7 1.3 12.6 6.8 9.6 1.3 12.6 6.5 27 8 22 305 49.6 6.7 52.9 32 01/14/2006 15:50:00 10.3 0.9 12.6 7.6 10.2 0.9 12.2 7.6 33 5 20 305 49.7 5.9 52.9 30.4 01/14/2006 16:00:00 10 1.1 12.6 7.6 9.9 1.2 12.6 6.8 33 6 27 305 47.2 7.6 51.4 30.1 01/14/2006 16:10:00 9.8 1.2 12.6 6.8 9.6 1.2 12.2 5.7 31 5 34 305 46 7.3 51 28.5 01/14/2006 16:20:00 9.3 1 12.2 7.6 8.9 1 11.5 6.5 30 7 16 305 42.5 9.9 51.4 25.8 01/14/2006 16:30:00 10.5 0.9 12.6 7.6 10.3 1 12.6 8 29 6 28 305 47.3 6.7 51.8 27 01/14/2006 16:40:00 9.7 1.1 12.6 6.8 9.3 1.1 11.8 6.5 32 6 33 305 44.6 4.7 48.4 23.4 01/14/2006 16:50:00 10.1 1 12.6 6.5 10 0.9 12.2 7.2 27 8 22 305 43.8 5.2 47.3 25.5 01/14/2006 17:00:00 10.3 0.9 12.6 7.6 10.1 1 12.6 7.2 23 6 24 305 41 6.4 47.7 16.5 01/14/2006 17:10:00 9.7 1 11.8 6.8 9.6 1 12.2 6.8 28 7 29 305 44.7 4.7 47.7 23.4 01/14/2006 17:20:00 9.3 0.9 11.1 6.8 9.2 1 11.8 6.5 31 11 30 305 45.2 5.2 48.4 5.4 01/14/2006 17:30:00 10.7 1 13.3 7.6 10.5 1.1 13.3 7.6 33 6 38 305 43.2 7.3 47.7 22.2 01/14/2006 17:40:00 10.4 1 12.6 6.8 10.3 1 12.6 6.8 33 7 37 305 46 5 48.4 24 01/14/2006 17:50:00 9.9 0.9 12.2 7.2 9.8 1 12.2 7.6 38 6 46 305 45.5 6.7 49.2 24.3 01/14/2006 18:00:00 10.4 1.1 13 8 10.3 1.2 13.3 7.6 31 6 30 305 46.5 4.4 48.8 23.4 01/14/2006 18:10:00 9.3 1 11.5 6.5 9 1 11.8 6.5 26 8 22 305 33.1 10.4 48.8 22.5 01/14/2006 18:20:00 9.7 1.1 12.2 7.2 9.5 1.1 12.6 6.8 30 7 15 305 43.6 10.4 52.5 27.6 01/14/2006 18:30:00 9.7 1.3 13.3 6.8 9.4 1.3 13.3 6.8 34 7 37 305 47 2.9 49.9 22.8 01/14/2006 18:40:00 10 1 13 6.8 9.8 0.9 13 7.2 37 6 35 305 38.7 10.8 48.1 22.8 01/14/2006 18:50:00 10.4 1.2 13.7 7.6 10.1 1.2 13.7 7.2 33 8 29 305 37.9 11.8 52.9 27.3 01/14/2006 19:00:00 10.6 1.1 13 8 10.3 1.1 13.3 7.6 32 7 41 305 46.6 9.5 52.9 22.2 01/14/2006 19:10:00 10.7 1.3 13.3 7.6 10.5 1.2 13.3 7.2 34 6 33 305 39.2 11.8 52.1 23.7 01/14/2006 19:20:00 10.1 1.1 12.6 7.2 9.9 1.1 13 7.2 38 6 40 305 49.5 5 51.8 27 01/14/2006 19:30:00 10.2 1.1 13 7.6 9.9 1.1 12.6 7.2 39 6 36 305 48.9 4 51.4 27 01/14/2006 19:40:00 10.2 1.1 12.2 6.8 10 1.1 12.2 6.8 40 5 36 305 47.1 7.3 51 27 01/14/2006 19:50:00 9.8 1.1 13 7.2 9.5 1.2 13.3 7.2 39 5 38 305 43.3 10.8 51.8 27.3 01/14/2006 20:00:00 10.4 1 13 8 10.2 1 12.6 8 34 6 31 305 50.2 0.5 51.8 48.4 01/14/2006 20:10:00 9.5 0.9 11.5 6.8 9.3 0.9 11.8 7.2 37 6 30 305 48.5 0.7 50.3 46.6 01/14/2006 20:20:00 9.9 0.8 11.8 8 9.7 0.9 12.2 7.6 37 5 34 305 47.7 0.9 49.5 45.9 01/14/2006 20:30:00 9.2 1 11.8 6.8 9.1 1 11.1 6.5 34 5 32 305 48.2 2.8 50.3 22.8 01/14/2006 20:40:00 9.2 1.2 12.6 6.5 9 1.2 13 6.5 36 5 33 305 42.3 10.4 51.8 26.4 01/14/2006 20:50:00 9.3 0.9 11.5 6.8 9.1 0.9 11.5 7.2 37 5 37 305 49.3 4.7 51.8 24.9 01/14/2006 21:00:00 8.3 0.9 11.8 6.1 8 0.9 11.5 6.1 35 6 30 305 46.9 7.3 51 26.7 01/14/2006 21:10:00 9.1 1 11.1 7.2 8.8 1 11.5 6.8 34 5 32 305 48.5 4.2 51 26.7 01/14/2006 21:20:00 8.9 0.9 11.1 6.8 8.6 1 11.1 5.7 32 5 22 305 46.8 5.9 52.1 26.4 01/14/2006 21:30:00 9.2 0.8 11.1 6.8 8.8 0.8 10.7 6.5 29 5 30 305 43.4 8.3 51.8 25.8 01/14/2006 21:40:00 8 1 10.3 5.7 7.8 1 9.9 5.3 27 6 26 305 39.7 11.8 52.9 25.5 01/14/2006 21:50:00 8 0.9 9.9 6.1 7.8 0.9 9.9 5.7 20 6 22 305 49.6 5 52.5 28.2 01/14/2006 22:00:00 9.5 1.1 11.5 6.1 9.4 1.2 11.8 5.7 18 5 5 305 49.5 4 52.5 28.5 01/14/2006 22:10:00 8.8 1 10.7 6.1 8.7 1.1 11.1 6.1 15 6 16 305 43.6 10.8 52.9 27.9 01/14/2006 22:20:00 9.1 0.9 11.1 6.5 8.9 1 11.5 6.8 11 6 9 305 51 4.4 52.9 28.8 01/14/2006 22:30:00 9.6 0.9 11.5 6.8 9.5 0.9 11.5 6.8 9 4 9 305 50.8 4 52.9 24.9 01/14/2006 22:40:00 9.5 0.7 11.1 7.2 9.4 0.7 11.5 6.8 9 4 11 305 49.1 4.4 52.5 24.6 01/14/2006 22:50:00 9 0.8 11.1 6.5 8.8 0.9 11.1 6.5 10 5 17 305 49 7 52.9 24.6 01/14/2006 23:00:00 9 1 11.1 6.5 8.9 1 11.1 6.5 13 4 12 305 49.8 4.5 52.1 24 01/14/2006 23:10:00 9.6 0.8 11.5 7.2 9.5 1 11.5 7.2 13 5 17 305 47.8 8 52.5 24 01/14/2006 23:20:00 9.1 1 11.8 6.8 8.8 1.1 11.5 6.1 12 5 7 305 49.5 5.6 51.8 24 01/14/2006 23:30:00 9.8 0.9 11.8 7.6 9.6 1 11.8 6.8 14 4 17 305 49.2 5.2 51.4 24 01/14/2006 23:40:00 9 1.2 11.8 6.5 8.9 1.2 11.8 6.8 19 5 13 305 48 6.4 51 24 01/14/2006 23:50:00 10 1 11.5 6.8 9.8 1 11.8 7.2 17 5 23 305 44.8 8.7 50.3 23.7 01/15/2006 00:00:00 10.1 0.8 11.8 7.2 9.9 0.9 11.8 6.8 19 6 21 305 31.1 5.9 49.9 24.6 01/15/2006 00:10:00 9.6 0.9 11.5 6.5 9.5 1 11.5 6.5 18 5 23 305 39.1 11.3 52.9 24.6 01/15/2006 00:20:00 8.9 1.1 11.1 6.5 8.7 1.1 11.1 6.1 13 5 10 305 50.9 6.4 52.9 24.3 01/15/2006 00:30:00 9.1 1.1 11.5 6.8 9 1.1 11.5 6.5 16 5 15 305 36.6 13.4 52.9 24 01/15/2006 00:40:00 9.6 0.8 11.1 7.2 9.5 0.8 11.5 7.2 17 5 20 305 51.3 4 52.9 24.6 01/15/2006 00:50:00 8.8 1 11.1 6.5 8.7 1 11.1 6.5 17 6 16 305 49.7 8 52.9 24.3 01/15/2006 01:00:00 9.9 0.8 11.5 7.6 9.8 1 11.5 7.2 18 5 23 305 52 0.5 52.9 49.9 01/15/2006 01:10:00 9.8 0.6 11.1 7.2 9.8 0.7 11.5 6.8 14 4 14 305 44.5 10.4 52.1 24 01/15/2006 01:20:00 9.7 0.9 11.5 7.2 9.5 1 11.5 7.2 13 4 13 305 48.6 7.3 52.1 24.9 01/15/2006 01:30:00 9.5 0.8 11.1 7.2 9.6 0.8 11.5 7.2 12 5 13 305 47.8 8 52.5 23.7 01/15/2006 01:40:00 9.8 0.9 12.2 7.2 9.7 1 12.2 7.2 13 4 13 305 49.3 6.4 52.9 23.7 01/15/2006 01:50:00 9.7 0.9 11.8 6.5 9.6 1 11.8 6.8 15 6 16 305 47.7 8.3 52.9 23.4 01/15/2006 02:00:00 10.1 1 11.8 7.6 10 1.1 12.2 7.2 16 6 18 305 49.1 7 52.9 24 01/15/2006 02:10:00 10.7 1 12.6 8 10.5 1 12.6 7.6 16 5 14 305 50.3 3.1 51.8 24 01/15/2006 02:20:00 10.6 1 12.6 8 10.5 1 13 7.2 15 5 19 305 45.5 10.4 52.9 23.7 01/15/2006 02:30:00 9.5 1.2 11.8 6.8 9.4 1.3 11.8 6.8 17 5 21 305 48.1 7.6 51.8 24 01/15/2006 02:40:00 10.1 1.1 12.6 6.8 9.9 1.2 12.2 6.1 23 6 25 305 48.1 6.2 51 23.4 01/15/2006 02:50:00 10.8 1.2 13 6.8 10.4 1.3 13 6.5 20 5 25 305 33.3 11.8 51.8 24 01/15/2006 03:00:00 11 1.3 13.7 7.6 10.7 1.3 13.7 7.2 21 6 20 305 33.3 12.3 51.4 24 01/15/2006 03:10:00 10.6 1.4 13.3 7.2 10.4 1.5 13.3 6.8 21 6 22 305 41.9 12.3 51.8 23.7 01/15/2006 03:20:00 10.4 1 12.6 6.8 10.2 1.1 13 7.2 23 6 16 305 47.5 7.3 51.4 22.8 01/15/2006 03:30:00 9.5 1.4 12.2 6.1 9.2 1.5 12.6 5.3 24 7 26 305 48.6 5 51 23.1 01/15/2006 03:40:00 8.5 1.1 10.7 5.7 8.1 1.1 11.1 5.3 25 7 25 305 39.3 12.9 50.6 21.6 01/15/2006 03:50:00 8.5 1 11.1 6.1 8.1 1 10.7 5.7 29 7 19 305 45.5 8.3 49.9 20.1 01/15/2006 04:00:00 8.7 0.9 11.1 6.5 8.5 1 10.7 6.1 28 6 28 305 43.3 6.4 47.7 18.4 01/15/2006 04:10:00 8.1 1 10.3 5.7 7.8 1 10.3 5.3 28 6 33 305 40.2 7.6 45.5 17.6 01/15/2006 04:20:00 8.1 1 10.3 4.9 7.9 1 9.5 5.3 28 6 28 305 40 7.6 45.5 16.7 01/15/2006 04:30:00 7.8 0.8 9.5 6.1 7.5 0.7 9.1 5.7 28 6 22 305 41.5 6.7 45.5 19.9 01/15/2006 04:40:00 8 0.9 10.3 6.1 7.7 1 9.9 5.3 26 5 25 305 41 7.3 47.3 19.6 01/15/2006 04:50:00 7.8 0.8 9.1 6.1 7.7 0.7 9.1 6.1 24 6 28 305 44.4 5.4 47.3 20.7 01/15/2006 05:00:00 7.7 0.7 9.1 4.9 7.6 0.8 9.1 4.9 19 5 23 305 42.7 6.2 46.3 22.2 01/15/2006 05:10:00 7.8 0.6 9.1 5.3 7.7 0.7 8.8 5.7 17 5 23 305 42.7 5.6 45.2 22.2 01/15/2006 05:20:00 7.5 0.7 8.8 5.7 7.4 0.7 9.1 5.7 18 6 14 305 43.2 2.7 45.2 20.1 01/15/2006 05:30:00 7.4 0.9 9.1 4.9 7.3 0.9 9.1 4.9 17 5 11 305 35.4 10.8 46.6 23.1 01/15/2006 05:40:00 7.8 0.5 9.1 6.5 7.7 0.6 9.1 5.7 16 3 12 305 43.7 4 46.3 19.6 01/15/2006 05:50:00 7.5 0.7 8.8 5.7 7.3 0.7 8.8 5.3 16 4 18 305 39.2 5.9 43.1 16.7 01/15/2006 06:00:00 7.3 0.8 9.1 5.3 7.1 0.8 8.8 4.9 19 6 18 305 39 7 44.1 21.3 01/15/2006 06:10:00 7.5 0.9 9.5 5.3 7.3 0.8 9.5 4.9 18 5 16 305 41.2 5.2 43.8 21.3 01/15/2006 06:20:00 8 0.8 10.3 5.7 7.8 0.8 10.3 6.1 19 5 14 305 39.3 7.3 43.8 19.3 01/15/2006 06:30:00 7.8 0.8 9.5 5.7 7.7 0.8 9.1 5.3 23 5 21 305 39.9 7.3 44.8 19.6 01/15/2006 06:40:00 8 0.7 9.1 6.1 7.7 0.7 9.1 5.7 21 5 21 305 30.5 10.4 43.4 20.1 01/15/2006 06:50:00 7.1 1 9.1 4.9 7 1 9.1 4.9 21 6 28 305 22.5 0.4 23.1 20.4 01/15/2006 07:00:00 7.8 0.6 8.8 6.1 7.7 0.6 9.1 6.1 18 3 16 305 23 0.2 23.7 21.6 01/15/2006 07:10:00 7.6 0.7 9.1 5.7 7.3 0.7 9.1 5.7 20 5 19 305 40.7 8.3 46.6 23.4 01/15/2006 07:20:00 7.4 0.7 9.1 5.3 7.3 0.7 9.1 5.7 18 5 15 305 41.2 6.2 44.5 24 01/15/2006 07:30:00 6.7 0.7 8.4 4.9 6.6 0.7 8.4 4.9 19 5 17 305 40.7 6.2 45.2 23.7 01/15/2006 07:40:00 7.3 0.6 8.4 5.7 7.1 0.7 8.8 4.9 20 4 16 305 40.2 6.4 45.5 23.4 01/15/2006 07:50:00 6.7 0.9 8.8 4.6 6.6 0.9 8.8 4.6 23 5 20 305 37.5 7 42.4 22.8 01/15/2006 08:00:00 6.3 0.6 7.6 4.9 6.1 0.6 7.6 4.2 18 5 12 305 38.6 5 41.3 21.3 01/15/2006 08:10:00 7.3 0.8 9.1 5.7 7.1 0.8 8.8 4.9 19 5 22 305 36.3 7.6 42.4 22.8 01/15/2006 08:20:00 6.7 0.7 8.4 5.3 6.6 0.7 8.4 5.3 15 5 20 305 38.9 4.2 42 22.5 01/15/2006 08:30:00 6.5 0.6 8 5.3 6.3 0.6 8 4.9 17 4 16 305 34.8 7.6 41.3 22.2 01/15/2006 08:40:00 6.9 0.7 8.4 4.9 6.7 0.7 8.8 4.9 19 4 21 305 37.5 5.6 41 22.2 01/15/2006 08:50:00 7.2 0.7 8.8 5.7 6.8 0.7 8.8 4.9 19 4 17 305 37.7 5.6 41.3 22.2 01/15/2006 09:00:00 7.5 0.6 8.8 5.7 7.2 0.6 8.8 5.7 21 4 21 305 38.9 4.7 42 23.4 01/15/2006 09:10:00 7.1 0.6 8.8 5.7 6.8 0.6 8.4 4.9 23 4 24 305 40.6 0.9 42 38.6 01/15/2006 09:20:00 7.5 0.5 8.4 5.7 7.2 0.5 8.8 5.7 24 4 27 305 39.7 5.2 43.1 22.8 01/15/2006 09:30:00 7.4 0.5 8.4 6.1 7.2 0.6 8.8 5.7 22 3 22 305 39.5 5.2 43.1 22.5 01/15/2006 09:40:00 7 0.6 8.4 5.3 6.8 0.6 8.8 4.9 23 4 23 305 40 0.9 42 36.9 01/15/2006 09:50:00 6.7 1 9.1 4.9 6.5 0.9 8.8 4.9 20 5 18 305 40.1 0.6 41.3 37.9 01/15/2006 10:00:00 7.7 0.9 10.3 5.7 7.5 0.9 9.9 5.7 18 5 18 305 39.1 0.9 41 36.9 01/15/2006 10:10:00 7.8 1 9.5 5.3 7.6 0.9 9.5 5.3 16 5 18 305 37.7 0.8 38.9 34.3 01/15/2006 10:20:00 8.1 1 9.9 5.3 7.9 1 9.9 5.3 15 5 19 305 35.2 6.7 40.6 19.9 01/15/2006 10:30:00 8.7 0.6 9.9 6.8 8.5 0.6 10.3 6.8 16 4 13 305 37.3 4.2 40.3 19.6 01/15/2006 10:40:00 7.9 0.8 9.5 6.1 7.8 0.7 9.5 5.7 16 5 18 305 36.6 5.6 40.6 19 01/15/2006 10:50:00 7.8 1 9.5 5.3 7.6 1 9.5 5.3 11 5 13 305 36.9 4.7 40.6 17.9 01/15/2006 11:00:00 7 0.9 8.8 4.6 6.8 0.9 9.1 4.9 11 5 8 305 34.8 6.2 40.3 20.1 01/15/2006 11:10:00 7.4 0.7 8.8 5.7 7.1 0.8 9.1 4.9 9 5 5 305 36.5 4.2 39.6 18.7 01/15/2006 11:20:00 7.7 0.8 9.5 5.7 7.4 0.9 9.1 5.3 11 5 9 305 36.2 5.2 39.6 20.1 01/15/2006 11:30:00 6.4 0.6 8 4.6 6.1 0.6 7.6 4.6 20 6 23 305 38.2 2.3 40.3 21 01/15/2006 11:40:00 6.3 0.8 9.1 4.2 6.2 0.8 8.8 4.6 15 6 11 305 38.2 5.4 42 19.9 01/15/2006 11:50:00 8.1 0.7 9.5 6.1 7.8 0.7 9.5 6.1 12 4 10 305 37.2 5.4 40.6 21.6 01/15/2006 12:00:00 8.2 0.5 9.5 6.5 7.9 0.6 9.5 6.5 16 4 13 305 36.7 5.2 40 21.9 01/15/2006 12:10:00 7.7 0.5 8.8 6.5 7.5 0.6 8.8 5.7 18 4 16 305 37.9 5.4 42.4 21.6 01/15/2006 12:20:00 7.3 0.7 9.1 5.3 7.1 0.6 8.4 5.3 16 5 21 305 36 7 41.3 20.7 01/15/2006 12:30:00 7.3 0.6 8.4 5.7 7.1 0.7 8.8 5.7 15 4 11 305 31.3 8.3 40.6 21.9 01/15/2006 12:40:00 8.1 0.8 9.9 6.1 7.9 0.8 9.5 5.7 15 4 15 305 28.3 9.1 42 21.9 01/15/2006 12:50:00 7.6 0.7 9.1 5.7 7.3 0.7 9.1 5.7 12 4 10 305 40 0.5 41.7 37.6 01/15/2006 13:00:00 8 0.6 9.1 6.1 7.9 0.7 9.5 5.7 15 3 19 305 32.2 9.5 42 20.4 01/15/2006 13:10:00 7.2 0.8 9.1 4.9 6.9 0.8 8.8 4.9 14 5 11 305 39.1 5.2 43.1 22.2 01/15/2006 13:20:00 6.7 0.6 8 4.6 6.5 0.6 8 4.9 21 5 15 305 39.4 4.2 41.7 21.9 01/15/2006 13:30:00 6.7 0.8 8.8 5.3 6.4 0.8 9.1 4.6 20 6 17 305 39 5 42.4 22.2 01/15/2006 13:40:00 7 0.7 8.4 5.3 6.7 0.7 8.4 4.9 22 5 31 305 35.6 8.3 43.1 22.2 01/15/2006 13:50:00 7.4 0.7 8.8 4.9 7.1 0.8 8.8 4.6 22 5 21 305 40.2 2.1 42 22.2 01/15/2006 14:00:00 7.3 0.7 8.8 5.7 7 0.7 8.8 5.3 23 5 18 305 38.3 0.1 38.9 37.6 01/15/2006 14:10:00 7.1 0.7 8.8 5.3 6.8 0.8 8.4 4.9 25 5 24 305 37.1 5.9 43.1 20.4 01/15/2006 14:20:00 6.9 0.6 8.8 5.3 6.7 0.6 8.4 5.3 28 5 23 305 32.2 9.5 43.1 22.2 01/15/2006 14:30:00 6.8 0.6 8.4 5.3 6.5 0.6 8.4 4.9 25 5 21 305 41.7 3.2 44.1 21 01/15/2006 14:40:00 6 0.6 7.6 4.6 5.9 0.6 7.2 4.6 23 6 22 305 32.2 9.5 42.7 20.7 01/15/2006 14:50:00 6.9 0.7 8.4 4.9 6.7 0.7 8 4.6 17 5 13 305 39.5 4.7 42.4 22.2 01/15/2006 15:00:00 7.3 0.9 8.8 4.9 7.1 1 8.8 4.6 14 4 17 305 37.5 5.2 42 18.4 01/15/2006 15:10:00 7.3 0.7 8.8 5.3 7.2 0.7 8.8 5.3 13 5 10 305 36.8 5.4 40.6 19.3 01/15/2006 15:20:00 7 0.8 8.8 4.9 6.9 0.8 8.4 5.3 14 7 7 305 36.8 4.4 41 19.9 01/15/2006 15:30:00 7.2 0.6 8.8 5.3 7 0.7 8.4 5.3 25 5 23 305 36.7 5.6 40.6 19.6 01/15/2006 15:40:00 8 0.9 9.5 5.7 7.8 1 9.5 5.3 21 4 19 305 35.9 6.7 40.6 21.3 01/15/2006 15:50:00 8.2 0.9 9.9 5.3 8.1 1 9.9 5.3 18 4 22 305 38 6.2 42 19.6 01/15/2006 16:00:00 7.8 0.8 9.5 5.7 7.8 0.8 9.1 5.7 17 5 15 305 39.2 3.1 42 22.8 01/15/2006 16:10:00 7.3 0.9 9.5 5.3 7.1 0.9 9.5 4.9 18 5 19 305 38 5.6 43.1 22.8 01/15/2006 16:20:00 8.1 0.9 9.5 5.7 7.9 0.9 9.5 5.7 22 5 27 305 38.1 5.6 42.7 22.2 01/15/2006 16:30:00 8.1 0.8 9.5 6.1 7.8 0.7 9.5 6.1 26 5 23 305 40.9 4.2 43.8 22.8 01/15/2006 16:40:00 7.6 0.7 9.5 6.1 7.5 0.7 9.5 5.3 23 5 24 305 40 6.4 44.1 21.9 01/15/2006 16:50:00 8 0.6 9.5 6.1 7.8 0.6 9.1 6.1 21 4 18 305 41.8 1.8 43.4 22.5 01/15/2006 17:00:00 8.2 0.7 9.5 6.5 8 0.8 9.9 6.1 21 4 22 305 41.5 4.5 44.8 22.2 01/15/2006 17:10:00 7.8 0.8 9.9 5.7 7.5 0.9 9.5 5.3 22 5 29 305 42.1 5.2 45.2 23.7 01/15/2006 17:20:00 7.7 0.8 9.5 5.7 7.4 0.8 9.5 5.3 22 5 22 305 42.5 1.2 43.8 24 01/15/2006 17:30:00 7.6 0.9 9.5 5.3 7.4 1 9.1 4.9 19 5 18 305 42.6 4.4 45.2 23.7 01/15/2006 17:40:00 8.4 0.5 9.5 6.8 8.1 0.6 9.5 6.1 17 3 19 305 41.4 5.9 44.5 23.7 01/15/2006 17:50:00 8.1 0.8 9.5 5.7 7.9 0.9 9.5 5.7 20 5 16 305 43.3 0.4 44.1 42.4 01/15/2006 18:00:00 8.1 1 9.9 6.1 7.8 0.9 9.9 5.7 23 5 23 305 42.5 0.1 43.1 41.3 01/15/2006 18:10:00 8 0.9 10.3 5.7 7.8 0.8 10.7 6.1 27 5 22 305 42.5 4.7 45.2 24.3 01/15/2006 18:20:00 8.1 1 10.3 6.1 7.9 1 10.3 6.1 27 6 27 305 43.1 2.7 44.5 24.9 01/15/2006 18:30:00 8.1 0.8 10.3 6.5 7.8 0.8 9.5 6.1 30 6 24 305 42.7 0.2 43.8 41 01/15/2006 18:40:00 7.9 0.7 9.5 5.7 7.6 0.7 9.1 5.7 27 5 24 305 42 0.3 43.1 40 01/15/2006 18:50:00 8.7 0.7 10.7 6.8 8.5 0.8 10.3 6.1 29 5 29 305 41.2 1.4 42 30.1 01/15/2006 19:00:00 9.4 0.7 10.7 7.2 9.2 0.8 11.1 6.8 25 6 33 305 41.2 2.7 43.1 24 01/15/2006 19:10:00 8.9 1 11.1 6.5 8.6 1 10.7 6.5 27 5 34 305 41.1 5.4 43.8 23.7 01/15/2006 19:20:00 8.8 1 10.7 6.1 8.5 1 11.1 6.1 28 5 35 305 41.5 5 44.5 24 01/15/2006 19:30:00 7.5 0.9 9.5 4.9 7.3 0.9 9.1 5.3 21 6 19 305 43 0.4 44.5 41.7 01/15/2006 19:40:00 7.8 0.8 9.5 5.7 7.7 0.8 9.5 5.7 20 5 22 305 42.4 0.3 43.1 40.6 01/15/2006 19:50:00 7.7 0.6 9.1 5.7 7.5 0.7 9.1 5.7 19 4 20 305 40.8 5 43.4 23.7 01/15/2006 20:00:00 6.8 0.6 8.4 4.9 6.6 0.7 8.4 4.9 15 4 13 305 39.4 5.6 43.1 22.2 01/15/2006 20:10:00 7.6 1 8.8 4.9 7.3 1 9.1 4.6 21 4 26 305 39.6 1.5 41 31 01/15/2006 20:20:00 7.6 0.6 9.1 6.1 7.4 0.6 8.8 5.7 19 4 17 305 37.1 4 41.3 20.4 01/15/2006 20:30:00 7.1 0.7 8.8 5.3 6.8 0.7 8.8 5.3 20 4 16 305 37.8 6.4 42.7 20.7 01/15/2006 20:40:00 7.4 0.9 9.1 5.3 7.2 0.9 9.1 4.9 23 4 16 305 39.2 4.5 43.4 21.6 01/15/2006 20:50:00 7 0.5 8.4 5.7 6.8 0.6 8.4 5.3 23 4 23 305 41.2 2.9 43.1 21.3 01/15/2006 21:00:00 6.5 0.5 7.6 5.3 6.3 0.5 7.6 4.9 16 4 18 305 28.6 9.5 43.1 20.7 01/15/2006 21:10:00 6.7 0.6 8 4.9 6.5 0.6 8 4.9 17 5 19 305 40.8 5.6 46.3 21.9 01/15/2006 21:20:00 6.8 0.5 8 5.3 6.7 0.5 8 5.3 19 4 17 305 40.4 3.2 43.8 21.3 01/15/2006 21:30:00 6.7 0.6 8 5.3 6.5 0.7 8.4 4.9 14 4 7 305 40 7.3 44.5 19.6 01/15/2006 21:40:00 7.6 0.7 9.1 5.7 7.4 0.7 8.8 5.7 13 5 22 305 42.3 0.9 43.8 38.9 01/15/2006 21:50:00 7.9 0.6 9.1 6.1 7.7 0.6 8.8 5.7 15 4 14 305 40.6 2.3 42.7 19.6 01/15/2006 22:00:00 7 0.6 8.4 5.3 6.8 0.6 8.4 5.3 12 5 11 305 40.9 0.8 42.4 37.9 01/15/2006 22:10:00 7.7 0.7 9.1 6.1 7.6 0.7 9.1 5.7 11 4 7 305 40 0.3 40.6 38.6 01/15/2006 22:20:00 7.6 0.7 9.1 5.3 7.4 0.8 9.5 5.7 9 5 9 305 40.2 0.2 41 39.6 01/15/2006 22:30:00 7.4 0.8 9.1 5.3 7.2 0.8 8.8 4.9 3 4 3 305 38.5 7 44.5 19.9 01/15/2006 22:40:00 6.9 0.7 8.4 5.3 6.8 0.7 8.4 4.9 5 5 359 305 38.2 6.4 43.8 19.9 01/15/2006 22:50:00 7 0.8 9.1 5.3 6.9 0.8 8.8 5.3 6 5 359 305 38.9 3.2 41.3 20.7 01/15/2006 23:00:00 6.8 0.8 8.8 4.9 6.7 0.8 8.8 4.6 8 5 11 305 27.4 9.5 44.1 19.9 01/15/2006 23:10:00 6.9 0.7 8.8 4.9 6.8 0.8 8.4 4.9 8 5 4 305 41.4 2.8 43.4 20.1 01/15/2006 23:20:00 7.2 0.6 8.4 5.3 7.1 0.7 8.4 5.3 9 4 10 305 34.1 10.4 43.4 20.7 01/15/2006 23:30:00 6.9 0.7 8.4 4.9 6.7 0.7 8.8 4.9 8 4 11 305 40.8 1.8 42.4 20.7 01/15/2006 23:40:00 6.9 0.7 8.4 4.9 6.8 0.7 8.4 5.3 2 5 5 305 38.9 6.2 42.7 20.1 01/15/2006 23:50:00 6.1 0.6 7.6 4.6 5.9 0.6 8 4.6 6 5 13 305 39.6 5 42 20.7 01/16/2006 00:00:00 7.1 0.7 8.4 5.3 7 0.7 8.4 5.3 6 5 12 305 37.6 6.2 42.4 19.9 01/16/2006 00:10:00 7 0.8 8.4 4.9 6.9 0.8 8.4 4.9 9 5 13 305 41.7 0 42.4 41.3 01/16/2006 00:20:00 7 0.7 8.8 5.3 6.8 0.7 8.8 5.3 10 4 9 305 41.3 0.2 42 40.3 01/16/2006 00:30:00 7.5 0.6 8.8 5.7 7.4 0.7 8.8 5.7 10 5 5 305 41.2 0.2 42 40.3 01/16/2006 00:40:00 7.5 0.9 9.1 5.3 7.4 0.9 9.5 5.3 11 5 10 305 40.3 0.2 41.3 38.9 01/16/2006 00:50:00 7.5 0.7 9.1 5.7 7.3 0.8 9.1 5.3 13 5 8 305 39.5 1 40.6 23.4 01/16/2006 01:00:00 7.9 0.6 9.1 6.5 7.7 0.6 9.1 6.1 16 4 19 305 38.9 0.5 40 36.9 01/16/2006 01:10:00 7.3 0.6 8.8 5.3 7.1 0.7 8.8 5.3 12 5 21 305 39.3 0.2 40 37.2 01/16/2006 01:20:00 6.9 0.7 8.8 5.3 6.7 0.7 8.4 4.6 8 5 358 305 39.3 0.2 40 37.2 01/16/2006 01:30:00 7.1 0.7 8.4 5.3 6.9 0.7 8.4 4.9 12 4 13 305 39.5 0.1 40.3 38.9 01/16/2006 01:40:00 6.9 0.6 8.8 5.3 6.8 0.6 8.8 4.9 10 4 6 305 38.9 0.2 39.3 37.6 01/16/2006 01:50:00 7.6 0.6 9.1 5.3 7.5 0.6 8.8 5.3 11 4 11 305 38.3 0.7 39.3 27.3 01/16/2006 02:00:00 7.5 1 9.5 4.9 7.3 1 9.5 4.6 11 5 8 305 22 4.4 39.6 20.4 01/16/2006 02:10:00 7.3 0.9 9.1 5.3 7.2 0.9 8.8 5.3 12 4 14 305 21.4 0.1 22.2 21 01/16/2006 02:20:00 7.4 0.6 8.8 5.7 7.2 0.6 8.8 5.7 12 4 12 305 22 0.1 22.5 20.7 01/16/2006 02:30:00 7.6 0.6 9.1 5.7 7.5 0.7 9.1 5.3 9 4 10 305 24.9 0.3 26.1 23.7 01/16/2006 02:40:00 7.6 0.6 9.1 5.3 7.4 0.7 8.8 4.9 5 5 3 305 32.5 9.1 45.2 24.9 01/16/2006 02:50:00 6.7 0.6 8 4.9 6.6 0.7 8 4.9 4 6 5 305 44.9 0 45.5 44.1 01/16/2006 03:00:00 7.8 0.5 8.8 5.7 7.8 0.6 9.1 5.7 3 4 0 305 44.6 0.3 45.5 43.4 01/16/2006 03:10:00 7.1 0.7 9.1 5.3 7.1 0.8 9.1 5.3 2 6 8 305 44.2 0.3 44.8 41.7 01/16/2006 03:20:00 7.6 0.7 9.1 4.9 7.6 0.8 9.1 5.3 4 6 12 305 44.1 0.3 44.8 43.4 01/16/2006 03:30:00 7.2 0.8 9.1 5.3 7.1 0.8 8.8 4.9 10 5 12 305 44 0.4 45.2 42.7 01/16/2006 03:40:00 7.5 0.9 9.1 5.3 7.4 1 9.5 5.3 10 5 11 305 43.8 0.3 44.5 43.1 01/16/2006 03:50:00 6.7 0.9 9.1 4.9 6.6 1 9.1 4.6 8 6 13 305 43.3 0.6 44.8 41.7 01/16/2006 04:00:00 7.3 1 9.5 5.3 7.2 1.1 9.5 4.9 11 7 14 305 42.9 0.3 43.8 42 01/16/2006 04:10:00 7.8 0.7 9.5 5.7 7.6 0.7 9.5 5.7 8 6 5 305 41.9 0.3 43.1 41 01/16/2006 04:20:00 7.4 0.8 9.5 5.3 7.3 0.9 9.1 5.3 11 5 10 305 28.5 7.3 41.7 22.5 01/16/2006 04:30:00 7.9 0.7 9.5 6.1 7.7 0.8 9.5 5.7 11 4 11 305 25.1 1.5 32.6 23.7 01/16/2006 04:40:00 7.2 0.8 9.1 4.9 7.1 0.8 9.1 4.6 10 5 11 305 31.3 4.7 36.9 24.9 01/16/2006 04:50:00 7.6 0.6 9.1 5.7 7.4 0.7 9.1 4.9 9 4 7 305 38.3 3.7 46.3 26.4 01/16/2006 05:00:00 7.4 0.6 9.1 5.7 7.2 0.7 8.8 5.3 10 4 17 305 38.9 5.4 45.2 25.8 01/16/2006 05:10:00 6.8 0.6 8.4 5.3 6.6 0.6 8.4 5.3 11 5 15 305 42.5 0.7 43.4 36.9 01/16/2006 05:20:00 6.9 0.7 8.4 4.9 6.7 0.7 8.4 4.6 9 6 12 305 38.1 7.3 44.1 25.8 01/16/2006 05:30:00 7.1 0.7 8.8 5.3 6.9 0.7 8.4 5.3 8 5 10 305 40.9 2.7 42.4 25.5 01/16/2006 05:40:00 6.8 0.7 8.4 4.6 6.6 0.8 8.8 4.6 10 5 10 305 38.1 6.7 42.4 25.5 01/16/2006 05:50:00 6.7 0.8 8.8 4.6 6.5 0.8 8.4 4.6 8 5 7 305 41.2 0.9 42.7 36.2 01/16/2006 06:00:00 7.4 0.7 9.1 4.9 7.3 0.7 8.8 4.9 8 5 7 305 40.1 0.2 40.6 38.6 01/16/2006 06:10:00 7.1 0.7 8.8 5.3 6.9 0.8 8.8 4.9 10 5 10 305 37.4 5.9 40.6 21 01/16/2006 06:20:00 7.3 0.7 8.8 4.9 7.1 0.8 8.8 4.9 9 4 10 305 33.5 7.6 41.3 23.7 01/16/2006 06:30:00 7.2 0.7 8.8 5.3 7.1 0.7 8.8 5.3 13 4 13 305 39.5 3.4 41.7 24 01/16/2006 06:40:00 7 0.7 8.8 4.9 6.8 0.7 8.8 4.9 13 5 14 305 32.5 8 42.7 24 01/16/2006 06:50:00 7.2 0.7 8.4 5.3 7 0.7 8.8 4.9 13 5 11 305 39.6 5.2 42 24.3 01/16/2006 07:00:00 7.6 0.8 8.8 5.7 7.4 0.8 9.1 4.9 12 4 13 305 36.3 8.3 43.8 24.3 01/16/2006 07:10:00 7.6 0.5 8.8 6.1 7.4 0.6 8.8 6.1 11 5 11 305 40.5 3.2 43.8 24.6 01/16/2006 07:20:00 7.7 0.8 9.9 5.3 7.5 0.8 9.9 5.7 12 5 17 305 40.6 0.4 41.3 34.3 01/16/2006 07:30:00 8 0.8 9.9 6.1 7.9 0.8 9.5 5.3 11 4 11 305 40 2.3 40.6 24.3 01/16/2006 07:40:00 8 0.9 9.9 5.7 8 1 10.3 5.7 12 6 8 305 33.3 7.3 40.6 24.3 01/16/2006 07:50:00 7.7 0.7 9.5 5.7 7.5 0.8 9.5 5.7 13 5 7 305 37.2 4.5 40.6 24.6 01/16/2006 08:00:00 8 0.8 9.5 5.7 7.7 0.8 9.5 5.7 14 5 8 305 33.2 5.9 41.3 14.3 01/16/2006 08:10:00 8 0.9 9.9 5.7 7.8 0.8 9.9 5.7 14 5 17 305 34.2 5.4 39.6 13.4 01/16/2006 08:20:00 8.1 0.8 9.9 6.1 7.9 0.9 9.9 6.1 12 5 15 305 38.5 2 40.3 22.2 01/16/2006 08:30:00 8.1 0.8 9.5 5.7 8 0.9 10.3 5.7 13 5 13 305 38.9 3.7 42 22.2 01/16/2006 08:40:00 8.3 0.6 9.9 6.1 8 0.7 9.9 6.5 11 4 21 305 35.7 7.6 41.7 22.2 01/16/2006 08:50:00 8 0.8 10.3 5.3 7.9 0.8 9.9 5.7 11 5 12 305 34.9 5.6 41.7 20.4 01/16/2006 09:00:00 8.1 0.8 9.9 6.5 7.9 0.9 9.9 6.1 12 5 5 305 35.7 4.7 39.6 19.3 01/16/2006 09:10:00 8.4 0.8 9.9 6.5 8.2 0.8 10.3 5.7 9 5 12 305 38.5 0.9 40 34.3 01/16/2006 09:20:00 8.3 0.8 10.7 5.3 8.1 0.8 9.9 6.1 14 6 20 305 27.9 9.1 39.6 18.1 01/16/2006 09:30:00 9.4 0.6 10.7 7.6 9.2 0.7 10.7 7.2 15 4 17 305 37.6 1.8 39.6 18.7 01/16/2006 09:40:00 9.5 0.6 10.7 7.6 9.3 0.8 11.5 6.5 13 4 11 305 36.7 4.4 40.3 19.3 01/16/2006 09:50:00 8.7 0.9 10.7 6.1 8.6 1 10.7 6.1 12 5 10 305 35.8 4.4 38.6 19.6 01/16/2006 10:00:00 9.1 0.7 10.7 6.8 8.9 0.9 10.7 6.5 10 4 27 305 36.4 0.5 37.2 33.3 01/16/2006 10:10:00 8.4 0.8 9.9 6.1 8.2 0.8 9.9 5.7 10 6 11 305 33.2 8 40.6 18.7 01/16/2006 10:20:00 8.8 0.6 10.3 6.8 8.6 0.7 10.3 6.1 12 5 10 305 33.2 6.4 38.6 19.3 01/16/2006 10:30:00 8.3 0.8 10.3 6.1 8.2 0.9 9.9 6.1 11 4 14 305 34.3 5.6 38.9 19.6 01/16/2006 10:40:00 8.9 0.8 10.7 6.8 8.7 0.9 11.1 6.1 8 4 7 305 37.7 0.5 38.9 35.9 01/16/2006 10:50:00 9.1 0.7 11.1 6.8 8.9 0.8 11.1 6.8 9 5 5 305 35.9 4.4 38.6 19 01/16/2006 11:00:00 8.8 1 10.7 5.7 8.7 1 11.1 6.1 10 4 12 305 33.4 8 39.6 19 01/16/2006 11:10:00 8.5 1 11.1 6.1 8.3 1 11.5 5.7 12 6 13 305 32.6 7.3 38.6 18.4 01/16/2006 11:20:00 9.1 0.8 11.1 6.8 8.9 0.9 10.7 6.5 12 4 9 305 35.9 4.7 39.6 19 01/16/2006 11:30:00 8.6 1 10.7 6.1 8.4 1 10.3 6.1 10 5 7 305 34.7 6.4 39.6 19.6 01/16/2006 11:40:00 8 0.8 9.9 6.1 7.9 0.8 9.9 5.7 7 5 6 305 34.4 5.9 37.9 19.6 01/16/2006 11:50:00 8.5 0.7 10.3 6.5 8.4 0.8 9.9 5.7 6 4 2 305 34.5 4.2 37.9 19.3 01/16/2006 12:00:00 7 0.8 9.1 4.9 6.9 0.8 8.8 4.9 3 6 1 305 20.4 2.9 36.2 19 01/16/2006 12:10:00 7.4 0.9 9.1 4.9 7.3 1 9.1 4.9 4 7 12 305 27.1 9.5 41.3 19.9 01/16/2006 12:20:00 7.9 0.8 9.5 5.3 7.7 0.8 9.9 5.3 6 4 4 305 38.6 0.6 40 36.9 01/16/2006 12:30:00 7.4 1 9.5 5.3 7.3 1.1 9.9 5.3 3 6 5 305 38.1 4.5 41.3 19.3 01/16/2006 12:40:00 8.4 0.8 9.9 5.7 8.2 0.9 10.3 5.3 6 5 5 305 38.9 1.8 41.3 31 01/16/2006 12:50:00 8.5 1 10.3 5.7 8.4 1.1 10.7 5.3 5 5 4 305 39.6 1.4 41.3 34.6 01/16/2006 13:00:00 8.4 0.8 9.9 6.5 8.3 0.8 10.3 6.1 9 5 4 305 39.5 1.1 41 24.3 01/16/2006 13:10:00 7.6 0.8 9.5 5.3 7.5 0.9 9.9 5.3 8 5 0 305 39.4 0.4 40.3 37.6 01/16/2006 13:20:00 7.8 0.9 9.9 5.7 7.7 1 10.3 5.3 7 6 6 305 39.8 0.7 40.6 30.1 01/16/2006 13:30:00 7.4 0.9 9.5 5.3 7.4 0.9 9.1 5.3 5 6 7 305 39.6 0.2 40.3 38.3 01/16/2006 13:40:00 7.7 0.9 9.5 5.3 7.6 0.9 9.1 5.3 7 5 6 305 26.8 9.1 39.6 18.7 01/16/2006 13:50:00 8.1 0.8 9.5 5.7 8 0.8 9.9 5.7 5 4 4 305 19.2 2.6 21.3 -21.8 01/16/2006 14:00:00 7.6 0.6 9.1 5.7 7.4 0.7 9.5 5.3 7 5 1 305 20.9 4.2 34.3 6.4 01/16/2006 14:10:00 7.2 0.8 9.1 4.9 7.1 0.8 9.1 4.9 5 6 4 305 25.9 11.3 40 -6.2 01/16/2006 14:20:00 7.3 0.7 9.1 5.3 7.2 0.8 9.1 5.3 5 6 359 305 37.3 0.9 40 28.5 01/16/2006 14:30:00 7.1 1 9.1 4.9 6.9 1 9.1 4.9 3 6 0 305 36 3.4 38.6 14.8 01/16/2006 14:40:00 7.1 0.9 8.8 4.9 6.9 0.8 8.8 4.9 3 5 3 305 36.7 4.4 39.3 16.7 01/16/2006 14:50:00 6.8 0.7 8.8 4.9 6.6 0.7 8.4 4.6 2 5 6 305 36.4 3.5 38.6 16.5 01/16/2006 15:00:00 7 0.8 8.8 4.9 6.9 0.8 8.8 4.9 6 5 0 305 33.5 5.6 38.3 14 01/16/2006 15:10:00 7.5 1 9.5 4.9 7.3 1 9.1 4.9 10 5 22 305 35.2 4 38.6 14.3 01/16/2006 15:20:00 7.4 0.7 9.1 5.3 7.2 0.7 9.1 5.7 10 5 8 305 36.1 3.7 39.3 16.2 01/16/2006 15:30:00 7.8 0.8 9.1 5.7 7.6 0.8 9.5 5.3 12 5 11 305 36.7 2.9 38.3 15.6 01/16/2006 15:40:00 7 0.7 8.4 4.6 6.8 0.7 8.4 4.6 10 6 10 305 35.9 3.8 37.9 15.6 01/16/2006 15:50:00 7.5 0.6 8.8 5.7 7.2 0.7 9.1 5.3 6 5 9 305 33.6 4.7 37.9 14 01/16/2006 16:00:00 7.4 0.7 8.8 5.3 7.3 0.7 8.8 5.7 7 5 11 305 34.8 2.9 37.6 15.9 01/16/2006 16:10:00 7.3 0.7 8.8 5.3 7.1 0.7 8.4 4.9 11 7 17 305 35.7 2.6 37.9 16.2 01/16/2006 16:20:00 6.7 0.6 8 4.9 6.5 0.6 8 4.6 10 4 12 305 36.1 2.2 37.6 16.5 01/16/2006 16:30:00 6.9 0.7 8.4 4.9 6.8 0.7 8.4 4.9 8 5 359 305 35.8 3.1 38.3 16.5 01/16/2006 16:40:00 6.8 0.8 8.4 4.6 6.6 0.8 8.4 4.2 9 5 14 305 36.7 2 37.6 17.3 01/16/2006 16:50:00 6.9 0.8 8.4 4.9 6.7 0.7 8.4 4.9 8 4 5 305 36.6 0.3 37.2 34.6 01/16/2006 17:00:00 7.4 0.5 8.4 5.7 7.2 0.5 8.8 5.3 9 4 8 305 36.9 1.1 37.6 18.4 01/16/2006 17:10:00 6.3 0.7 7.6 4.6 6.1 0.8 8 4.6 11 5 12 305 36.7 4.7 39.6 18.1 01/16/2006 17:20:00 6.5 0.7 8 4.6 6.3 0.7 8 4.2 8 5 12 305 37.7 0.3 38.9 36.2 01/16/2006 17:30:00 6.6 0.6 8 4.9 6.4 0.6 7.6 4.9 12 4 12 305 34.7 6.4 37.9 17.3 01/16/2006 17:40:00 6.8 0.6 8 5.3 6.6 0.6 8 5.3 10 4 7 305 18.6 0.8 19.6 14 01/16/2006 17:50:00 6.4 0.7 8.4 4.9 6.2 0.6 8 4.2 10 5 7 305 29.1 11.3 43.1 15.3 01/16/2006 18:00:00 6.1 0.6 7.6 4.6 6 0.6 7.6 4.6 10 5 6 305 40.7 1 43.1 36.9 01/16/2006 18:10:00 6.8 0.5 8.4 5.7 6.6 0.5 8 5.3 5 4 5 305 40.1 0.2 40.6 38.6 01/16/2006 18:20:00 6.8 0.6 8 4.6 6.7 0.7 8 4.9 7 5 359 305 40 0.6 41.7 37.2 01/16/2006 18:30:00 6.7 0.4 8 5.3 6.6 0.5 7.6 4.9 13 3 11 305 38.3 1.1 41 31.7 01/16/2006 18:40:00 6.7 0.8 8 4.6 6.5 0.8 7.6 4.6 13 3 16 305 37.9 3.1 40 17 01/16/2006 18:50:00 7.1 0.6 8.8 4.9 6.8 0.6 8 4.9 11 3 14 305 37.1 2.1 38.6 16.7 01/16/2006 19:00:00 6.6 0.5 8 5.3 6.4 0.6 8 4.6 14 5 25 305 37.8 2.5 39.3 17.6 01/16/2006 19:10:00 6.8 0.6 8 4.9 6.6 0.6 8 4.9 15 4 16 305 37.8 0.4 38.6 36.6 01/16/2006 19:20:00 6.8 0.6 8.8 4.9 6.6 0.6 8.4 4.6 8 5 8 305 37.7 1.6 38.3 17.3 01/16/2006 19:30:00 6.5 0.7 8 4.9 6.2 0.7 8 4.6 12 5 10 305 38 2.8 40 17.3 01/16/2006 19:40:00 6.4 0.8 8 4.6 6.2 0.8 8 4.2 15 4 19 305 37.6 4.5 39.6 16.7 01/16/2006 19:50:00 6.8 0.6 8.4 4.9 6.5 0.7 8 4.6 13 5 5 305 38.8 0.2 39.6 37.6 01/16/2006 20:00:00 6.3 0.5 7.6 4.6 6.1 0.6 8 4.9 11 4 12 305 35.7 2.2 39.3 16.7 01/16/2006 20:10:00 6.4 0.5 7.6 4.9 6.1 0.5 7.2 4.6 17 4 12 305 34.1 4 35.9 15.6 01/16/2006 20:20:00 7 0.6 8.4 5.3 6.7 0.6 7.6 4.6 15 3 18 305 35.3 0.1 35.9 33.3 01/16/2006 20:30:00 6.1 0.7 7.6 4.6 5.9 0.6 7.2 4.2 10 5 16 305 36.7 1.4 39.6 32.3 01/16/2006 20:40:00 6.7 0.5 8 5.3 6.5 0.5 7.6 4.9 8 5 1 305 37.8 2.2 40.6 24.9 01/16/2006 20:50:00 5.8 0.5 7.6 4.6 5.5 0.6 6.8 4.2 10 4 9 305 34.7 4 40 16.7 01/16/2006 21:00:00 6.4 0.6 8 4.9 6.2 0.6 7.6 4.6 10 4 7 305 35 2.9 39.3 17.9 01/16/2006 21:10:00 6.6 0.7 8.4 4.9 6.4 0.6 8.4 4.9 10 6 5 305 35.2 3.2 41.7 17 01/16/2006 21:20:00 7.8 0.8 9.1 5.3 7.4 0.8 9.5 5.3 15 4 10 305 39.5 2 41.3 32 01/16/2006 21:30:00 8.1 0.8 9.9 5.7 7.9 0.8 9.5 5.7 15 4 14 305 37.4 4 41.3 27 01/16/2006 21:40:00 8.1 0.6 9.1 6.1 7.8 0.6 9.1 6.1 15 4 10 305 34.6 0 34.9 34.3 01/16/2006 21:50:00 7.2 0.7 9.5 5.3 6.9 0.7 9.5 4.6 14 5 12 305 34.8 4.5 37.6 17.3 01/16/2006 22:00:00 8.3 0.6 9.9 6.5 8 0.7 10.3 6.5 15 4 11 305 36.3 0.1 36.9 35.6 01/16/2006 22:10:00 8 0.9 9.9 6.1 7.7 1 9.5 5.3 16 4 12 305 36.3 2.1 42 18.4 01/16/2006 22:20:00 7.1 0.6 8.8 5.7 6.9 0.6 8.4 5.3 15 5 18 305 39.3 2.4 42.4 34.9 01/16/2006 22:30:00 7 0.6 8.4 5.3 6.8 0.6 8.4 5.3 11 6 12 305 37.7 4.4 43.8 17.6 01/16/2006 22:40:00 7.5 0.6 8.8 5.7 7.2 0.7 8.8 4.9 9 4 8 305 35.8 0.7 37.2 30.7 01/16/2006 22:50:00 7 0.7 8.4 5.3 6.7 0.7 8.4 4.9 11 5 12 305 34 5.4 37.9 18.4 01/16/2006 23:00:00 7.1 0.6 8.8 5.3 6.9 0.7 8.4 4.9 5 5 8 305 36.4 0.4 37.6 35.3 01/16/2006 23:10:00 7.9 0.8 9.5 5.7 7.6 0.8 9.1 5.3 14 5 12 305 34.7 2.4 37.6 19 01/16/2006 23:20:00 6.5 0.7 8.4 4.6 6.3 0.7 8 4.9 11 5 15 305 36.4 2.2 38.3 19 01/16/2006 23:30:00 5.3 0.6 6.8 3.8 5.2 0.6 6.8 3.4 6 5 3 305 35.2 4.5 38.9 19 01/16/2006 23:40:00 6.4 0.6 8 4.6 6.3 0.7 8 4.6 9 5 16 305 35.9 2.5 37.2 19.3 01/16/2006 23:50:00 6.8 0.6 8 5.3 6.7 0.6 8 4.6 10 5 11 305 35.3 0.2 36.2 34.3 01/17/2006 00:00:00 6.7 0.6 8 4.9 6.6 0.7 8.4 4.2 11 5 16 305 34.7 0 35.3 34.3 01/17/2006 00:10:00 7.1 0.5 8.4 4.9 7 0.5 8 5.3 9 3 12 305 34.8 0 34.9 34.6 01/17/2006 00:20:00 6.4 0.6 8 4.9 6.2 0.7 8 4.6 7 5 10 305 34.8 0 34.9 34.6 01/17/2006 00:30:00 6 0.6 7.2 4.6 5.7 0.6 7.2 4.2 4 5 355 305 34.9 0 35.3 34.6 01/17/2006 00:40:00 6.1 0.6 8 4.2 6 0.5 7.2 4.6 4 4 2 305 37.4 3.7 43.8 34.9 01/17/2006 00:50:00 6.3 0.8 8 4.9 6 0.7 8 4.2 9 6 7 305 40.5 2.8 43.4 34.9 01/17/2006 01:00:00 7.3 0.6 8.4 5.3 7 0.6 8.4 5.7 10 5 4 305 36.9 1.8 42.4 35.9 01/17/2006 01:10:00 7.8 0.7 9.5 5.7 7.5 0.8 9.5 5.7 8 4 10 305 36.4 0 36.6 36.2 01/17/2006 01:20:00 7.7 0.5 8.8 6.1 7.5 0.6 8.8 5.7 8 3 7 305 39.2 3.8 45.2 36.2 01/17/2006 01:30:00 6.5 0.7 8.4 4.9 6.3 0.7 8.4 4.2 11 5 6 305 44 2.9 46.6 33.9 01/17/2006 01:40:00 6.8 0.6 8 5.3 6.6 0.6 8.8 4.9 13 5 9 305 41.2 4 45.2 29.2 01/17/2006 01:50:00 6.4 1 8.8 4.2 6.2 1 8.8 4.2 9 5 10 305 35.1 5.2 37.9 19.6 01/17/2006 02:00:00 6.7 0.6 8 5.3 6.5 0.6 8 4.9 13 4 14 305 37.2 0.2 37.9 35.3 01/17/2006 02:10:00 6.8 0.5 7.6 5.3 6.5 0.5 7.6 4.9 8 3 10 305 37 0 37.6 36.6 01/17/2006 02:20:00 6.9 0.5 8 5.7 6.6 0.5 8 5.3 7 3 8 305 37.1 0.2 37.6 36.6 01/17/2006 02:30:00 6.3 0.6 7.6 4.6 6.1 0.6 7.6 4.2 15 6 29 305 37.8 1.9 43.4 35.3 01/17/2006 02:40:00 6.4 0.7 7.6 4.6 6.2 0.8 7.6 4.2 11 4 11 305 38.9 5.2 44.5 19.9 01/17/2006 02:50:00 6.7 0.4 7.6 5.3 6.4 0.5 7.2 4.9 9 3 10 305 38.1 4.5 44.5 20.1 01/17/2006 03:00:00 6.2 0.5 7.2 4.6 5.9 0.6 7.2 4.2 12 4 11 305 38.7 3.8 44.5 26.7 01/17/2006 03:10:00 6.2 0.6 7.2 4.6 5.9 0.6 7.6 4.2 10 4 11 305 38.7 2.7 43.1 36.2 01/17/2006 03:20:00 6.7 0.5 8 5.3 6.4 0.6 7.6 4.9 8 4 10 305 35.6 5.2 43.4 20.1 01/17/2006 03:30:00 6.1 0.6 8 4.6 5.8 0.6 7.6 4.2 12 6 10 305 37.4 2.2 43.1 20.4 01/17/2006 03:40:00 6 0.7 8 4.6 5.7 0.7 7.2 4.2 16 5 20 305 40.4 3.5 45.5 36.6 01/17/2006 03:50:00 6.6 0.6 8.4 4.9 6.4 0.7 8 4.6 11 5 10 305 44 1.6 45.9 36.9 01/17/2006 04:00:00 6.4 0.6 7.6 4.6 6.1 0.6 7.2 3.8 9 5 12 305 43.1 3.1 45.9 32.6 01/17/2006 04:10:00 6.2 0.6 7.6 4.6 5.9 0.6 7.6 4.2 7 5 2 305 43.1 2.9 46.3 32 01/17/2006 04:20:00 5.9 0.6 7.2 4.6 5.7 0.6 7.2 4.2 7 5 14 305 42.5 3.7 45.9 29.2 01/17/2006 04:30:00 6.3 0.7 8 4.6 6.1 0.7 8 4.6 5 5 2 305 40.4 3.2 44.8 34.3 01/17/2006 04:40:00 7 0.6 8.4 5.3 6.8 0.7 8 4.9 5 4 9 305 42.2 2.2 44.1 35.9 01/17/2006 04:50:00 6.8 0.5 8 5.7 6.6 0.5 8 5.3 7 4 7 305 39.2 3.1 43.8 35.3 01/17/2006 05:00:00 7 0.7 8.8 5.3 6.8 0.7 8.8 4.9 7 5 6 305 36.9 0 37.2 36.6 01/17/2006 05:10:00 6.3 0.7 8.4 4.9 6 0.6 8 4.2 14 6 20 305 34.3 5.2 37.2 19 01/17/2006 05:20:00 6.9 0.6 8.4 5.3 6.6 0.7 8.4 4.9 17 5 18 305 46.1 5.2 52.1 33.6 01/17/2006 05:30:00 7.1 0.8 8.8 4.9 6.8 0.8 8.8 4.6 18 5 14 305 48.8 2.1 51.8 41.3 01/17/2006 05:40:00 7.9 0.6 9.1 6.1 7.6 0.6 9.1 6.1 13 4 14 305 46.3 2.6 50.6 40.6 01/17/2006 05:50:00 7.4 0.7 9.1 5.3 7.2 0.8 9.1 5.3 9 5 9 305 44.5 2.4 50.6 41 01/17/2006 06:00:00 7.9 0.6 9.5 6.5 7.7 0.7 9.5 5.7 13 4 16 305 42.5 1.1 44.5 38.3 01/17/2006 06:10:00 7.1 0.6 8.8 5.3 6.8 0.7 8.4 4.9 14 4 17 305 42.4 0.5 43.1 40 01/17/2006 06:20:00 6.4 0.7 8 4.9 6.1 0.6 8 4.6 11 5 12 305 41.2 1.2 42.4 24.6 01/17/2006 06:30:00 5.8 0.7 7.2 4.2 5.6 0.7 7.6 3.8 10 6 5 305 41.6 0.3 42 40.3 01/17/2006 06:40:00 6.2 0.6 8 4.9 6 0.6 7.6 4.6 7 6 11 305 41.5 0.2 42.7 37.9 01/17/2006 06:50:00 6 0.7 7.6 4.2 5.7 0.7 7.2 4.2 5 6 2 305 43.2 1.9 47 31.7 01/17/2006 07:00:00 6 0.5 7.2 4.6 5.7 0.5 7.2 4.2 7 5 4 305 38.1 10.4 47.3 18.4 01/17/2006 07:10:00 5.8 0.8 7.6 3.8 5.7 0.8 7.6 3.8 8 3 2 305 41.9 10.8 51.8 18.7 01/17/2006 07:20:00 6.5 0.5 8 4.6 6.3 0.5 7.6 4.6 11 4 14 305 46.1 2.7 50.3 42 01/17/2006 07:30:00 6.5 0.6 8 4.9 6.3 0.7 8 4.6 10 5 10 305 41.8 1.4 43.8 21.6 01/17/2006 07:40:00 6.5 0.8 8 4.6 6.3 0.9 8 4.2 6 6 5 305 31.5 6.7 48.8 17.6 01/17/2006 07:50:00 6 0.8 8 4.6 5.9 0.7 7.6 4.2 8 5 0 305 31.5 6.2 51.8 19 01/17/2006 08:00:00 7.3 0.6 8.4 5.7 7 0.6 8.4 5.7 14 4 8 305 48.6 2.3 52.1 44.1 01/17/2006 08:10:00 6.9 0.5 8.4 5.3 6.7 0.6 8 4.9 13 5 11 305 46 2.3 51.8 43.1 01/17/2006 08:20:00 5.9 0.7 7.6 4.2 5.6 0.6 7.2 4.2 4 6 5 305 44 0.6 45.5 41.7 01/17/2006 08:30:00 5.7 0.5 7.2 4.6 5.6 0.5 7.2 4.2 5 5 356 305 42.3 6.2 45.2 19.6 01/17/2006 08:40:00 5.8 0.9 7.2 3.8 5.6 0.8 7.2 3.8 5 3 2 305 42.9 1.7 44.5 22.5 01/17/2006 08:50:00 5.9 0.4 6.8 4.2 5.7 0.5 6.8 4.6 3 4 3 305 41.8 1.2 43.1 23.1 01/17/2006 09:00:00 5.4 0.5 6.5 4.6 5.2 0.4 6.1 4.2 6 4 3 305 26.1 9.1 42.7 20.1 01/17/2006 09:10:00 5 0.4 6.1 3.8 4.7 0.4 5.7 3.8 9 4 6 305 27.2 4.7 34.6 20.7 01/17/2006 09:20:00 5.5 0.5 6.8 4.2 5.2 0.6 6.5 3.8 15 4 19 305 41.2 9.1 52.9 20.7 01/17/2006 09:30:00 5.6 0.4 6.5 4.6 5.3 0.4 6.1 4.2 13 4 16 305 49.1 2.3 52.5 40.6 01/17/2006 09:40:00 5.1 0.5 6.5 4.2 4.8 0.5 6.1 3.8 14 4 8 305 47.2 1.1 51.8 43.4 01/17/2006 09:50:00 5.5 0.4 6.5 4.2 5.2 0.5 6.5 3.8 13 3 13 305 46.3 1 48.8 42.4 01/17/2006 10:00:00 5.2 0.5 6.5 3.4 4.8 0.6 6.1 3.4 16 4 11 305 45.9 0.4 47.3 44.5 01/17/2006 10:10:00 4 0.8 6.1 2.6 3.8 0.7 5.3 2.6 36 13 13 305 44.9 1.1 46.3 28.5 01/17/2006 10:20:00 3.8 0.5 5.3 2.6 3.6 0.4 4.6 2.6 31 10 15 305 44.9 0.5 45.9 42.7 01/17/2006 10:30:00 4.8 0.6 6.5 3.4 4.5 0.6 6.1 3 20 7 13 305 44.8 0.4 45.9 42.4 01/17/2006 10:40:00 5.5 0.5 6.5 4.2 5.2 0.4 6.5 4.2 15 3 16 305 34 11.8 45.9 21 01/17/2006 10:50:00 4.3 1 6.1 3 4.1 0.9 6.1 2.6 35 16 13 305 37 5.4 45.5 21.6 01/17/2006 11:00:00 3.8 0.4 4.9 3 3.8 0.4 4.9 3 45 7 31 305 36.3 5.2 45.9 21.3 01/17/2006 11:10:00 4.3 0.5 5.7 2.6 4.3 0.4 5.3 3.4 37 8 35 305 37.7 4.4 46.3 21.3 01/17/2006 11:20:00 4.6 0.5 6.1 3.8 4.4 0.4 5.7 3.8 30 6 25 305 37.8 3.7 45.9 21.3 01/17/2006 11:30:00 5 0.4 6.1 4.2 4.7 0.5 5.7 3.8 27 4 23 305 34 5.4 44.8 21.3 01/17/2006 11:40:00 5.2 0.5 6.1 3.4 4.9 0.5 6.1 3.4 29 5 28 305 39.7 3.7 45.5 21.6 01/17/2006 11:50:00 4.6 0.7 6.5 2.6 4.4 0.6 5.3 3 30 7 19 305 40.6 3.4 45.5 36.6 01/17/2006 12:00:00 5 0.6 6.1 3.4 4.6 0.6 6.1 3 26 5 25 305 41.2 3.1 47 32.6 01/17/2006 12:10:00 4.5 0.6 6.1 3.4 4.3 0.5 5.7 3.4 31 5 37 305 39.6 2.9 47.3 29.2 01/17/2006 12:20:00 4.5 0.6 5.7 3.4 4.2 0.6 5.7 3 31 7 24 305 38.9 2.6 45.9 21.6 01/17/2006 12:30:00 5 0.6 6.1 3.4 4.7 0.6 6.1 3.4 26 6 24 305 38.3 5 46.3 20.7 01/17/2006 12:40:00 5 0.6 6.5 3.8 4.9 0.6 6.5 3 25 5 29 305 37.5 3.7 44.1 21.3 01/17/2006 12:50:00 5.1 0.5 6.5 3.8 5 0.5 6.1 3.8 35 6 39 305 40.8 2.1 43.8 35.9 01/17/2006 13:00:00 4.2 0.4 5.3 3.4 4.1 0.3 4.9 3 43 7 41 305 37.4 4.2 46.3 21.3 01/17/2006 13:10:00 4.3 0.4 5.7 3.4 4.3 0.3 5.3 3.4 51 5 45 305 39.6 2.5 44.5 30.4 01/17/2006 13:20:00 4.3 0.5 5.3 3.4 4.2 0.4 5.3 3.4 45 6 40 305 38.5 2.6 43.4 21.3 01/17/2006 13:30:00 4.7 0.5 5.7 3.4 4.7 0.5 6.1 3.4 47 5 39 305 38.1 4.4 45.5 20.4 01/17/2006 13:40:00 4.7 0.3 5.3 3.8 4.7 0.3 5.7 3.4 47 5 46 305 39.3 4.4 45.5 20.4 01/17/2006 13:50:00 4.2 0.4 5.3 3.4 4.2 0.4 5.3 3.4 53 5 48 305 38.8 5.9 45.5 19.6 01/17/2006 14:00:00 3.9 0.3 4.9 3 3.8 0.4 4.6 3 52 7 58 305 38.7 3.2 45.5 20.1 01/17/2006 14:10:00 4 0.4 5.3 3 4 0.4 5.3 3 48 8 44 305 39.9 3.1 45.5 26.1 01/17/2006 14:20:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 43 5 29 305 39.1 4.7 44.5 14.8 01/17/2006 14:30:00 4 0.3 4.6 3.4 3.9 0.3 4.6 3.4 47 6 45 305 35.2 4 44.1 16.5 01/17/2006 14:40:00 4 0.3 5.3 3.4 3.9 0.3 4.9 3 41 8 45 305 34.1 2.2 36.9 17.3 01/17/2006 14:50:00 3.7 0.4 4.9 2.6 3.6 0.3 4.9 2.6 48 7 40 305 36.2 4.5 43.1 18.7 01/17/2006 15:00:00 4.1 0.5 5.3 3 4.1 0.5 5.3 3 48 5 43 305 41.2 3.4 45.2 29.5 01/17/2006 15:10:00 4.5 0.3 5.3 3.8 4.4 0.3 5.7 3.8 44 6 39 305 41.8 1.6 44.8 33.3 01/17/2006 15:20:00 4.1 0.4 5.3 3 4.1 0.5 5.3 3 51 6 63 305 42.3 1.4 45.5 35.3 01/17/2006 15:30:00 4.4 0.3 5.3 3.8 4.4 0.3 5.3 3.4 49 5 37 305 40.2 3.7 44.8 27 01/17/2006 15:40:00 4.8 0.4 5.7 3.8 4.8 0.4 5.7 4.2 45 5 42 305 38.6 3.7 44.5 22.2 01/17/2006 15:50:00 4.8 0.4 6.1 3.8 4.7 0.4 6.1 3.8 41 6 37 305 36 4.4 42 17.9 01/17/2006 16:00:00 4.7 0.4 5.7 3.8 4.6 0.4 5.7 3.8 40 5 47 305 40.3 2.9 44.8 21.3 01/17/2006 16:10:00 5.1 0.5 6.1 4.2 4.9 0.5 6.1 3.8 33 5 29 305 37.7 2.7 42.4 17 01/17/2006 16:20:00 5.2 0.4 6.1 4.2 5 0.3 6.1 4.2 37 4 32 305 38.1 3.1 43.1 16.7 01/17/2006 16:30:00 5.7 0.4 6.5 4.6 5.5 0.4 6.5 4.6 41 4 37 305 36.5 0.8 38.3 31.7 01/17/2006 16:40:00 5 0.5 6.1 3.8 4.8 0.5 6.1 3.8 39 6 40 305 33.9 9.1 45.5 18.7 01/17/2006 16:50:00 5 0.3 5.7 4.2 4.7 0.3 5.7 3.8 32 4 35 305 40 5.4 45.2 -3.3 01/17/2006 17:00:00 4.9 0.5 6.5 3.8 4.6 0.4 6.1 3.8 35 4 30 305 41.1 5 46.6 8.7 01/17/2006 17:10:00 5.3 0.4 6.5 4.2 5 0.4 6.1 4.2 35 5 37 305 43.3 2.3 45.9 29.8 01/17/2006 17:20:00 5.2 0.4 6.5 4.2 4.9 0.4 6.1 4.2 33 4 37 305 42.9 3.7 48.1 25.5 01/17/2006 17:30:00 5 0.5 6.5 4.2 4.8 0.4 6.1 3.8 36 8 29 305 41.4 3.7 47.3 29.5 01/17/2006 17:40:00 4.9 0.4 6.1 3.4 4.8 0.4 6.1 3.8 43 5 43 305 39 4.5 44.1 29.5 01/17/2006 17:50:00 5 0.4 6.1 3.8 4.7 0.4 5.7 3.4 35 10 33 305 40.8 4.7 47 15.9 01/17/2006 18:00:00 4.9 0.4 5.7 3.8 4.6 0.5 5.7 3 39 6 42 305 41.2 3.1 45.5 31 01/17/2006 18:10:00 5.2 0.4 6.5 4.6 5 0.3 6.5 4.2 39 5 29 305 41.5 2.3 44.5 31.4 01/17/2006 18:20:00 5 0.4 6.1 4.2 4.8 0.4 6.5 3.8 45 5 36 305 39 3.7 45.5 27.3 01/17/2006 18:30:00 4.5 0.4 5.7 3.4 4.4 0.4 4.9 3.4 40 9 30 305 41 4.5 49.9 17 01/17/2006 18:40:00 4.8 0.4 6.1 3.8 4.7 0.4 5.7 3.8 37 7 29 305 43.1 4.5 51 27.3 01/17/2006 18:50:00 5.1 0.5 6.5 3.8 4.8 0.4 6.1 3.8 34 8 17 305 44.7 3.8 51.8 30.7 01/17/2006 19:00:00 5.1 0.4 6.1 4.2 5 0.3 6.1 4.2 43 4 39 305 44.4 4 51.4 29.2 01/17/2006 19:10:00 5.3 0.3 6.1 4.6 5.1 0.4 6.1 4.2 39 5 41 305 46.6 3.4 51.8 34.9 01/17/2006 19:20:00 4.8 0.5 6.5 3.8 4.8 0.5 6.5 3.4 44 5 42 305 42.6 6.2 49.9 11.8 01/17/2006 19:30:00 4.7 0.4 6.1 3.8 4.6 0.4 5.7 3.8 45 8 37 305 40.2 4.5 47.7 11.8 01/17/2006 19:40:00 5 0.4 6.1 3.8 4.9 0.4 5.7 3.8 41 6 45 305 41 4.7 47.3 18.1 01/17/2006 19:50:00 5.3 0.6 6.5 3.8 5.3 0.7 6.8 3.8 55 5 58 305 39.8 7 47.3 13.2 01/17/2006 20:00:00 6 0.4 6.8 4.9 6 0.4 7.2 4.9 56 4 59 305 40.5 7.6 49.5 13.7 01/17/2006 20:10:00 5.8 0.4 6.8 4.9 5.7 0.5 6.8 4.6 52 4 52 305 46 3.1 50.6 26.7 01/17/2006 20:20:00 5.8 0.5 7.2 4.6 5.7 0.6 7.2 4.2 51 5 42 305 45.7 5 51.4 15.3 01/17/2006 20:30:00 6.1 0.3 6.8 4.9 5.9 0.4 6.8 4.9 47 4 45 305 43.5 8.7 51 -23.4 01/17/2006 20:40:00 6.1 0.5 7.6 4.9 5.9 0.5 7.6 4.6 44 4 42 305 42.1 5 48.4 9.7 01/17/2006 20:50:00 6.1 0.5 7.2 4.9 6 0.6 7.2 4.6 46 5 46 305 42.1 6.4 48.1 4.9 01/17/2006 21:00:00 6 0.5 7.2 4.9 5.8 0.5 7.2 4.6 44 6 45 305 41.1 7.6 49.5 6.4 01/17/2006 21:10:00 6.3 0.5 7.6 5.3 6.1 0.5 7.2 4.9 42 4 37 305 30.9 3.8 37.2 21.6 01/17/2006 21:20:00 5.8 0.5 7.2 4.9 5.7 0.5 6.8 4.2 46 8 45 305 40.4 6.7 49.9 21.6 01/17/2006 21:30:00 6.3 0.4 7.6 4.9 6.2 0.5 7.6 4.9 58 4 50 305 41.8 3.8 47.3 22.2 01/17/2006 21:40:00 6.8 0.3 7.6 6.1 6.8 0.4 8 5.7 60 3 61 305 42.9 4 48.4 22.5 01/17/2006 21:50:00 7.2 0.4 8.4 6.1 7.3 0.5 8.4 5.7 58 4 55 305 41 2.2 44.1 21.9 01/17/2006 22:00:00 6.9 0.5 8.4 5.7 6.9 0.5 8 5.7 57 4 60 305 39.3 2.9 41.7 21.3 01/17/2006 22:10:00 6.8 0.3 7.6 5.7 6.8 0.4 8 5.3 57 3 54 305 39.1 0.7 40.3 32.6 01/17/2006 22:20:00 5.9 0.6 6.8 4.6 5.8 0.6 6.8 4.2 57 5 62 305 36.7 2.7 38.9 17.9 01/17/2006 22:30:00 6.6 0.4 7.6 5.3 6.7 0.4 8 5.7 56 4 63 305 35.1 0.4 36.2 33.3 01/17/2006 22:40:00 6.4 0.5 8.4 4.9 6.5 0.6 8.4 4.9 54 5 54 305 40.4 1.9 41.7 34.3 01/17/2006 22:50:00 6 0.5 6.8 4.6 6 0.5 7.2 4.6 50 6 56 305 42.4 0.4 43.4 41.3 01/17/2006 23:00:00 6.4 0.6 8.4 4.9 6.2 0.7 7.6 4.2 51 6 56 305 41.2 0.9 42 33.3 01/17/2006 23:10:00 6.4 0.6 8 4.6 6.4 0.7 8.4 4.9 52 5 44 305 36.7 3.7 41.3 31.7 01/17/2006 23:20:00 6.1 0.4 7.2 5.3 6 0.5 7.6 4.9 51 4 50 305 36.9 3.4 42 32.6 01/17/2006 23:30:00 5.8 0.4 7.2 4.6 5.7 0.5 7.2 4.2 49 4 43 305 39 1 40.6 37.6 01/17/2006 23:40:00 5.8 0.5 6.8 4.6 5.6 0.5 6.8 4.2 47 5 57 305 39.4 0.5 40.6 37.2 01/17/2006 23:50:00 6.2 0.5 7.2 4.9 5.9 0.5 6.8 4.6 46 3 44 305 39.2 0 39.6 38.9 01/18/2006 00:00:00 5.8 0.4 6.8 4.9 5.6 0.4 6.5 4.6 51 5 44 305 39.1 0 39.6 38.6 01/18/2006 00:10:00 5.3 0.6 6.5 4.2 5.1 0.6 6.5 3.4 49 5 54 305 38.9 0 39.3 38.3 01/18/2006 00:20:00 6 0.5 7.2 4.9 5.9 0.5 7.6 4.6 45 6 40 305 38.7 0.2 39.3 37.9 01/18/2006 00:30:00 5.9 0.7 7.2 4.2 5.8 0.6 7.2 4.2 44 5 44 305 37.7 1 39.6 36.2 01/18/2006 00:40:00 5 0.6 7.2 4.2 4.9 0.6 6.8 3.4 51 4 53 305 38.6 0.9 39.6 36.6 01/18/2006 00:50:00 5.9 0.7 7.6 4.6 5.8 0.6 7.6 4.6 42 6 29 305 39.2 6.2 47.3 28.8 01/18/2006 01:00:00 6.2 0.4 7.2 4.9 6.1 0.5 7.2 4.9 48 5 47 305 35.8 4.7 45.5 29.2 01/18/2006 01:10:00 5.5 0.5 7.2 4.6 5.4 0.5 6.8 4.6 49 6 36 305 39.2 0.5 43.8 38.6 01/18/2006 01:20:00 5.2 0.4 6.5 4.2 5 0.5 6.1 3.8 47 5 47 305 40.7 2.3 46.6 37.9 01/18/2006 01:30:00 6 0.7 7.6 4.2 5.9 0.7 7.6 4.2 49 6 53 305 42.5 2.7 46.3 38.3 01/18/2006 01:40:00 5.5 0.4 6.5 4.6 5.3 0.4 6.5 4.2 41 5 39 305 42 3.2 45.5 35.3 01/18/2006 01:50:00 5.7 0.5 6.8 4.6 5.5 0.5 7.6 4.2 45 5 45 305 41.2 2.8 45.5 34.9 01/18/2006 02:00:00 5.5 0.4 6.8 4.2 5.3 0.5 6.8 4.2 40 5 49 305 45.9 2.6 49.5 38.3 01/18/2006 02:10:00 5.8 0.4 6.8 4.6 5.5 0.4 6.5 4.6 33 5 30 305 43.3 3.8 49.5 25.8 01/18/2006 02:20:00 6.1 0.5 7.2 4.9 5.8 0.5 6.8 4.6 34 5 30 305 37.2 2.8 43.1 26.1 01/18/2006 02:30:00 5.6 0.6 7.2 4.2 5.4 0.6 6.8 4.2 41 4 46 305 38.3 3.8 44.5 27.3 01/18/2006 02:40:00 6.2 0.5 7.2 4.9 5.9 0.5 6.8 4.9 37 5 39 305 39.8 2.7 45.2 36.6 01/18/2006 02:50:00 5.4 0.5 6.8 3.4 5.1 0.5 6.8 3.8 43 6 36 305 39.4 3.2 44.8 27.3 01/18/2006 03:00:00 6.2 0.6 7.6 4.9 5.9 0.6 7.6 4.6 34 5 38 305 37.9 2.6 42.7 27.3 01/18/2006 03:10:00 6.3 0.4 7.6 4.9 6.1 0.5 7.2 4.6 40 5 29 305 38.7 1.5 44.8 36.9 01/18/2006 03:20:00 5.9 0.4 7.2 4.2 5.7 0.5 6.8 4.6 41 5 39 305 38.6 3.7 45.2 27.6 01/18/2006 03:30:00 6.1 0.6 7.6 4.9 5.8 0.6 7.2 4.6 37 4 31 305 37.1 2.7 39.6 26.7 01/18/2006 03:40:00 6.4 0.6 8 5.3 6 0.6 8 4.9 36 6 30 305 37.2 2.7 42.7 27.3 01/18/2006 03:50:00 6.6 0.7 8.4 4.9 6.4 0.7 8.4 4.6 37 4 40 305 37.4 2.9 42.7 33.9 01/18/2006 04:00:00 6.7 0.6 8.4 4.9 6.5 0.6 8 4.9 37 5 33 305 34.9 0.7 39.6 34.3 01/18/2006 04:10:00 6.8 0.7 8.4 4.9 6.5 0.7 8 4.9 36 5 33 305 35.5 0.8 40.6 34.6 01/18/2006 04:20:00 7 0.8 8.8 4.9 6.7 0.8 8.8 4.9 33 6 24 305 35.4 0.7 40 34.6 01/18/2006 04:30:00 6.9 0.7 8.4 4.9 6.7 0.7 8.4 4.9 37 6 41 305 34.6 1.5 39.3 32.3 01/18/2006 04:40:00 6.5 0.6 8 4.9 6.3 0.6 8 4.9 35 7 33 305 32.2 3.7 38.6 24.6 01/18/2006 04:50:00 6.3 0.7 8 4.2 6.1 0.7 7.6 4.2 34 5 32 305 35.9 3.7 41 26.4 01/18/2006 05:00:00 5.5 0.6 6.8 3.8 5.2 0.6 6.8 3.4 39 6 31 305 38.1 3.2 42 16.2 01/18/2006 05:10:00 5.7 0.6 7.2 4.6 5.5 0.7 7.2 4.2 40 5 44 305 34.3 2.9 40.6 27.6 01/18/2006 05:20:00 5.5 0.6 6.8 3.8 5.2 0.6 7.2 3.8 42 6 46 305 36.1 5.9 42.7 13.7 01/18/2006 05:30:00 5.2 0.6 6.8 3.8 5 0.6 6.5 3.8 48 6 40 305 35.7 2.5 41.7 14.5 01/18/2006 05:40:00 5.3 0.5 6.8 3.8 5.2 0.5 6.5 3.8 53 7 57 305 35.3 3.8 42.4 13.7 01/18/2006 05:50:00 5.5 0.4 6.8 4.2 5.4 0.4 6.5 4.2 44 6 39 305 36.8 2.1 42 28.2 01/18/2006 06:00:00 5.6 0.6 7.2 4.2 5.4 0.6 6.8 4.2 40 6 48 305 34.6 1.8 39.6 32 01/18/2006 06:10:00 5.6 0.7 7.2 3.8 5.4 0.7 6.8 3.4 37 6 41 305 35.3 1.9 39.6 32 01/18/2006 06:20:00 6.1 0.7 8 4.9 5.8 0.7 8.4 4.6 30 6 30 305 35.7 2.8 40.6 27.3 01/18/2006 06:30:00 6.3 0.6 8 4.6 5.9 0.6 7.2 4.2 32 5 30 305 32.5 3.7 37.9 25.2 01/18/2006 06:40:00 5.9 0.8 8 3.8 5.6 0.8 8 3.4 34 5 30 305 33.9 3.7 40.3 23.4 01/18/2006 06:50:00 6.3 0.6 7.6 4.9 6 0.6 7.6 4.6 32 5 30 305 36.4 2 41.7 33.6 01/18/2006 07:00:00 6.3 0.6 7.6 4.9 6 0.6 7.6 4.9 32 4 29 305 36.4 2 41.3 33.6 01/18/2006 07:10:00 6.1 0.5 8 4.9 5.9 0.5 8 4.6 34 5 35 305 37.4 1.9 41.3 33.3 01/18/2006 07:20:00 6.3 0.7 8.4 4.9 6 0.7 8.4 4.2 35 6 32 305 37.7 2.1 42 34.9 01/18/2006 07:30:00 5.9 0.6 7.6 4.2 5.6 0.6 8 4.2 34 5 34 305 36.8 2.1 41.7 34.3 01/18/2006 07:40:00 6.1 0.6 7.6 4.9 5.9 0.6 7.2 4.2 36 5 34 305 36 2.9 41.3 28.2 01/18/2006 07:50:00 6.1 0.5 7.6 4.9 5.8 0.5 7.2 4.6 37 5 40 305 39.2 2.3 43.1 33.3 01/18/2006 08:00:00 5.9 0.5 7.2 4.9 5.7 0.5 6.8 4.6 38 5 36 305 33.8 3.8 42 27 01/18/2006 08:10:00 5.7 0.7 8 4.2 5.4 0.7 7.6 4.2 37 5 30 305 33 3.7 38.9 27.6 01/18/2006 08:20:00 6.3 0.6 7.6 4.9 6 0.6 7.6 4.6 39 5 43 305 34.9 3.2 40 27.3 01/18/2006 08:30:00 6 0.5 7.2 4.6 5.8 0.5 7.2 4.6 44 5 49 305 36.8 3.1 42 27.6 01/18/2006 08:40:00 6.3 0.5 7.6 4.9 6 0.5 7.2 4.6 42 4 40 305 36.5 2.6 41.7 27.6 01/18/2006 08:50:00 5.5 0.5 7.2 4.6 5.3 0.5 6.8 4.6 39 5 40 305 35.4 4 41.7 26.1 01/18/2006 09:00:00 6.2 0.7 7.6 4.6 5.9 0.6 7.2 4.2 37 6 30 305 36.2 2.5 41.7 27.3 01/18/2006 09:10:00 6.2 0.6 8 4.6 6 0.5 7.2 4.9 37 6 33 305 37.6 2 41.7 32 01/18/2006 09:20:00 6.7 0.6 8 5.3 6.4 0.6 8 4.9 32 5 26 305 37 1.1 41.7 32.6 01/18/2006 09:30:00 6.6 0.6 8 4.9 6.3 0.7 8 4.9 29 5 39 305 36.7 0.8 37.9 32.6 01/18/2006 09:40:00 6.8 0.8 8.4 4.9 6.4 0.8 8 3.8 31 6 31 305 36.6 0.5 37.6 32.6 01/18/2006 09:50:00 6.8 0.8 8.4 5.3 6.5 0.7 8.4 4.9 29 5 32 305 33.6 4.2 37.2 25.2 01/18/2006 10:00:00 7.1 0.6 8.4 5.3 6.7 0.6 8.4 4.9 28 4 25 305 32.3 3.7 37.9 26.7 01/18/2006 10:10:00 7.1 0.8 8.8 5.3 6.7 0.8 8.8 4.9 27 5 26 305 37.3 3.7 43.4 27.3 01/18/2006 10:20:00 7.4 0.6 8.8 5.7 7.1 0.6 8.8 5.3 30 5 24 305 37.4 2.2 42.7 33.6 01/18/2006 10:30:00 7.9 0.6 9.5 6.5 7.6 0.7 9.1 5.7 27 5 30 305 37.7 1.8 43.4 35.9 01/18/2006 10:40:00 8.1 0.9 10.3 5.7 7.8 0.9 9.5 5.3 24 4 23 305 37.8 1.8 42 36.2 01/18/2006 10:50:00 7.4 0.9 9.1 5.3 7 0.9 9.1 5.3 24 5 22 305 36.9 1.5 41.7 35.3 01/18/2006 11:00:00 7.8 0.8 9.1 5.3 7.6 0.8 9.1 5.7 27 5 18 305 36.8 1.8 41 34.9 01/18/2006 11:10:00 7.6 1.1 10.3 5.3 7.4 1.2 10.3 5.3 30 7 25 305 35.9 2.1 41.7 28.2 01/18/2006 11:20:00 8.4 0.8 10.7 5.7 8.2 0.8 9.9 6.1 32 5 33 305 36.6 1.2 41.3 34.9 01/18/2006 11:30:00 6.7 1 9.5 4.9 6.5 1 9.5 4.6 35 5 30 305 36.6 0.5 40.6 35.3 01/18/2006 11:40:00 6.2 1 8.4 4.6 5.9 1 8 4.2 33 5 33 305 37.7 1.4 42.7 36.9 01/18/2006 11:50:00 6 0.9 8 4.2 5.8 0.9 8 4.2 36 5 34 305 37.1 1.1 42 34.3 01/18/2006 12:00:00 5.7 0.5 6.8 4.6 5.4 0.5 6.5 4.2 38 5 41 305 36.7 1.2 41.3 35.3 01/18/2006 12:10:00 5.5 0.5 6.8 4.6 5.2 0.5 6.5 3.8 40 5 39 305 37.1 1.6 42.4 35.6 01/18/2006 12:20:00 5.5 0.4 6.5 4.6 5.2 0.4 6.8 4.2 43 7 33 305 36.1 0.2 36.9 35.3 01/18/2006 12:30:00 5.9 0.4 6.8 4.9 5.6 0.5 6.8 4.2 40 5 39 305 35.9 1.4 41 34.3 01/18/2006 12:40:00 5.5 0.5 6.8 4.6 5.3 0.4 6.5 4.2 48 4 51 305 36.2 2 40.6 34.3 01/18/2006 12:50:00 5 0.4 6.1 3.8 4.8 0.4 6.1 3.8 50 5 52 305 33.8 4 40 25.5 01/18/2006 13:00:00 5.5 0.6 6.5 3.8 5.4 0.6 6.8 3.8 51 4 50 305 31.9 3.8 39.3 27 01/18/2006 13:10:00 5.6 0.4 6.5 4.2 5.6 0.4 6.5 4.6 51 4 51 305 34.7 2.9 39.3 26.7 01/18/2006 13:20:00 5.1 0.5 6.5 3.8 5 0.5 6.1 3.8 55 5 53 305 35.5 3.2 43.4 27.3 01/18/2006 13:30:00 5.3 0.4 6.1 4.2 5.2 0.4 6.5 3.8 48 5 66 305 37.6 0.4 41.3 35.9 01/18/2006 13:40:00 4.6 0.5 6.1 3 4.3 0.5 5.7 3 50 5 53 305 37.7 0.3 38.6 36.6 01/18/2006 13:50:00 4.8 0.5 6.1 3.8 4.5 0.6 6.1 3.4 47 4 50 305 37 2.1 41.3 34.3 01/18/2006 14:00:00 4.4 0.3 5.3 3.8 4.1 0.3 4.9 3 44 4 44 305 36.1 1.9 42 34.3 01/18/2006 14:10:00 4 0.3 4.9 3.4 3.8 0.3 4.6 3 45 4 39 305 32.6 5 42 20.4 01/18/2006 14:20:00 3.8 0.3 4.9 3 3.6 0.3 4.6 2.6 53 6 60 305 30.5 4.4 36.9 19 01/18/2006 14:30:00 4 0.4 4.9 3.4 3.8 0.4 4.9 3 56 5 43 305 29.5 4.5 35.3 21.3 01/18/2006 14:40:00 4 0.4 4.9 3 3.8 0.4 4.6 2.6 53 6 38 305 29.3 10.4 43.4 -8.2 01/18/2006 14:50:00 4.8 0.4 5.7 3.4 4.6 0.4 5.7 3 49 4 48 305 35.8 4.5 44.1 26.4 01/18/2006 15:00:00 4.2 0.4 5.3 3 4 0.5 4.9 2.6 54 5 56 305 33 11.3 43.1 -5.1 01/18/2006 15:10:00 4.4 0.4 5.3 3.4 4.3 0.4 5.7 3 49 6 56 305 38.7 4 42 26.4 01/18/2006 15:20:00 3.8 0.4 4.9 2.6 3.6 0.4 4.9 3 50 5 57 305 37.2 4.7 42 25.2 01/18/2006 15:30:00 4 0.4 4.9 3 3.9 0.4 4.9 2.6 46 5 49 305 37.2 4.7 43.8 19.6 01/18/2006 15:40:00 3.9 0.4 4.9 3 3.8 0.4 4.6 2.6 41 5 38 305 40.3 3.2 44.5 33.9 01/18/2006 15:50:00 3.5 0.4 4.6 2.6 3.2 0.4 4.2 2.3 51 6 39 305 40.3 2.9 44.5 33.3 01/18/2006 16:00:00 3.4 0.3 4.2 2.6 3.2 0.4 3.8 2.3 55 7 52 305 40.2 3.4 44.1 29.2 01/18/2006 16:10:00 3.5 0.4 4.6 2.6 3.2 0.4 4.6 2.3 52 6 43 305 41.1 2.2 44.8 29.2 01/18/2006 16:20:00 3.3 0.4 4.6 2.6 3.1 0.4 4.9 2.3 49 5 53 305 40.1 3.2 45.2 27.6 01/18/2006 16:30:00 3.6 0.3 4.6 2.6 3.4 0.4 4.2 2.3 49 6 62 305 39.8 2.9 46.3 27.3 01/18/2006 16:40:00 3.4 0.3 4.2 2.6 3.2 0.3 3.8 2.3 51 5 50 305 41.3 2.7 46.3 37.9 01/18/2006 16:50:00 3.3 0.3 4.2 2.6 3.1 0.3 3.8 2.3 52 5 54 305 39.4 2.1 45.9 36.6 01/18/2006 17:00:00 3.5 0.3 4.2 2.6 3.2 0.3 4.2 2.3 60 6 68 305 44.7 4 48.4 31.7 01/18/2006 17:10:00 4 0.4 4.9 3 3.9 0.4 4.9 3 59 5 65 305 46.8 1.5 47.7 38.3 01/18/2006 17:20:00 4.2 0.3 4.9 3.4 4.1 0.3 4.9 3 56 4 55 305 46 1.8 47.7 37.2 01/18/2006 17:30:00 4.1 0.3 4.9 3 4 0.3 4.6 3 57 5 60 305 39.3 1.8 46.3 37.9 01/18/2006 17:40:00 3.6 0.3 4.2 3 3.5 0.3 4.2 2.6 60 5 61 305 38.8 0.2 39.3 38.3 01/18/2006 17:50:00 3.7 0.3 4.6 2.6 3.3 0.5 4.2 2.3 59 5 68 305 38.7 1.2 42 28.8 01/18/2006 18:00:00 4 0.3 4.9 3.4 3.7 0.4 4.6 3 58 4 60 305 39.4 3.4 42 19 01/18/2006 18:10:00 4.2 0.3 4.9 3 4 0.3 4.9 3.4 57 5 65 305 40.8 0.2 41.3 40.3 01/18/2006 18:20:00 4 0.3 4.9 3 3.9 0.3 4.9 3 56 4 62 305 40.6 0.3 41.3 39.6 01/18/2006 18:30:00 4 0.4 4.6 2.6 3.8 0.4 4.6 2.6 60 4 54 305 40.7 0.1 41.3 40 01/18/2006 18:40:00 4.1 0.3 4.9 3.4 3.7 0.4 4.9 2.6 60 4 60 305 40.5 0 41 39.6 01/18/2006 18:50:00 3.8 0.5 4.9 2.3 3.6 0.5 4.6 2.3 62 6 61 305 40.1 0.2 41 38.6 01/18/2006 19:00:00 3.6 0.5 4.9 2.6 3.5 0.5 4.9 2.3 58 5 58 305 39.6 0 40.3 39.3 01/18/2006 19:10:00 3.6 0.4 4.6 2.6 3.3 0.4 4.2 2.3 52 5 54 305 38.8 0.9 39.6 25.5 01/18/2006 19:20:00 3.7 0.3 4.9 3 3.4 0.3 4.6 2.6 57 6 66 305 38.9 1 40.6 29.8 01/18/2006 19:30:00 3.8 0.3 4.9 3 3.6 0.3 4.2 2.3 56 7 48 305 33.6 5.2 40.3 27 01/18/2006 19:40:00 3.6 0.4 4.6 2.6 3.4 0.5 4.6 2.6 51 6 57 305 36.4 0.5 38.6 34.9 01/18/2006 19:50:00 3.5 0.4 4.9 2.6 3.3 0.4 4.9 2.3 48 6 42 305 36.6 1.1 38.9 34.3 01/18/2006 20:00:00 3.8 0.6 5.3 2.6 3.6 0.6 4.9 2.3 43 7 45 305 36.2 7.6 47.3 13.2 01/18/2006 20:10:00 4.2 0.5 5.7 3 3.9 0.5 4.9 2.6 29 10 33 305 40.2 1 47.3 37.2 01/18/2006 20:20:00 5.3 0.4 6.8 4.6 4.9 0.5 6.1 3.4 25 6 22 305 41.2 3.2 47.3 20.7 01/18/2006 20:30:00 4 0.4 5.7 3 3.7 0.4 4.9 3 41 8 27 305 41.8 2.1 47.3 38.6 01/18/2006 20:40:00 4.2 0.3 4.9 3.4 4 0.3 4.6 3 47 5 45 305 41.3 1.7 43.4 37.9 01/18/2006 20:50:00 4.1 0.3 5.3 3 3.7 0.3 4.6 3 39 5 33 305 39.2 0 39.6 38.6 01/18/2006 21:00:00 3.9 0.3 4.9 3 3.7 0.3 4.6 2.6 44 6 42 305 41.3 1.1 43.1 26.1 01/18/2006 21:10:00 3.7 0.5 5.3 2.6 3.5 0.4 4.9 2.6 42 7 35 305 41 0.8 42 38.3 01/18/2006 21:20:00 4 0.5 5.3 3 3.8 0.5 4.9 2.6 47 5 33 305 40.6 0.6 43.1 37.6 01/18/2006 21:30:00 4.8 0.3 5.3 4.2 4.6 0.3 5.3 4.2 45 4 54 305 42.1 0.3 43.1 41.3 01/18/2006 21:40:00 5.3 0.4 6.5 4.2 4.8 0.4 5.7 3.8 36 6 32 305 37 7.3 42 24.6 01/18/2006 21:50:00 5.5 1 7.6 4.2 5.1 1 7.6 3.8 23 6 19 305 41.2 6.4 45.9 25.8 01/18/2006 22:00:00 6.7 0.5 8 5.3 6.4 0.6 7.6 4.6 22 5 18 305 41 3.1 44.1 19.6 01/18/2006 22:10:00 6.2 0.7 8.4 4.6 5.9 0.7 7.6 4.6 22 5 17 305 35.7 1.8 43.4 31.7 01/18/2006 22:20:00 6 0.6 8 4.2 5.6 0.6 7.6 4.2 17 4 18 305 36.4 5.9 44.8 7.9 01/18/2006 22:30:00 6.7 0.5 8 4.9 6.4 0.6 8.4 4.9 15 4 18 305 39.4 2.2 43.8 20.4 01/18/2006 22:40:00 6.3 0.7 8 4.6 6 0.7 8.4 4.2 15 4 11 305 40.4 5.4 43.4 21 01/18/2006 22:50:00 6.1 0.6 7.6 4.6 5.8 0.6 7.6 4.2 16 5 13 305 40.1 1 41.7 37.9 01/18/2006 23:00:00 6 0.6 7.2 4.6 5.8 0.6 7.2 3.8 11 5 9 305 41.5 0.1 42 40.3 01/18/2006 23:10:00 6.1 0.6 7.2 4.6 5.9 0.6 7.2 4.2 13 4 13 305 41.2 0 41.7 40.6 01/18/2006 23:20:00 5.8 0.5 7.2 4.6 5.6 0.6 7.2 4.2 13 3 12 305 41.5 0.4 42.4 35.3 01/18/2006 23:30:00 5.6 0.6 6.8 3.8 5.3 0.6 6.8 3.8 13 4 9 305 41.8 0 42.4 41.3 01/18/2006 23:40:00 6.1 0.4 7.2 4.9 5.9 0.4 6.8 4.6 14 3 16 305 41.7 0 42 41.3 01/18/2006 23:50:00 5.3 0.5 6.8 4.2 5 0.6 6.8 3.8 13 3 16 305 41.6 0 42 41.3 01/19/2006 00:00:00 5.5 0.4 6.5 4.2 5.2 0.5 6.1 3.8 9 5 12 305 41.4 0.2 42 40 01/19/2006 00:10:00 5.4 0.5 6.8 4.2 5.2 0.5 6.5 4.2 7 6 4 305 41.7 0 42 41 01/19/2006 00:20:00 5.3 0.5 6.8 4.2 5.1 0.6 6.8 3.8 10 4 12 305 41.7 0.2 43.8 40.3 01/19/2006 00:30:00 4.8 0.6 6.1 3.4 4.5 0.6 6.1 3 15 6 28 305 42.2 1.6 47.7 23.4 01/19/2006 00:40:00 5.1 0.4 6.5 4.2 4.8 0.4 5.7 3.8 21 6 21 305 42.4 0.7 47.7 41 01/19/2006 00:50:00 5 0.5 6.8 3.8 4.7 0.6 6.8 3.4 16 6 23 305 45 2.7 48.8 39.6 01/19/2006 01:00:00 5 0.4 5.7 3.8 4.6 0.5 5.7 3.4 15 4 12 305 44.8 3.4 48.8 22.8 01/19/2006 01:10:00 5 0.4 6.1 4.2 4.8 0.4 5.7 3.8 14 4 11 305 43.3 3.4 47.3 23.1 01/19/2006 01:20:00 5.1 0.5 6.5 4.2 4.8 0.4 5.7 3.8 15 4 11 305 38.3 5.9 44.5 23.4 01/19/2006 01:30:00 4.6 0.4 6.1 3.8 4.4 0.4 5.3 3.4 9 4 12 305 40.6 1.5 43.1 33.9 01/19/2006 01:40:00 4.5 0.6 5.7 3.4 4.3 0.6 5.7 3 8 5 7 305 39.7 0.5 40.6 34.9 01/19/2006 01:50:00 4 0.5 4.9 2.6 3.6 0.6 4.9 1.9 17 7 7 305 41 1.2 44.1 38.9 01/19/2006 02:00:00 3 0.4 4.2 1.9 2.9 0.4 4.2 1.9 36 12 25 305 39.3 4 44.5 24.3 01/19/2006 02:10:00 4.6 0.5 5.7 3 4.3 0.5 5.3 3 20 3 19 305 40.5 0.6 42.4 37.2 01/19/2006 02:20:00 4.3 0.4 5.3 3.4 4 0.4 4.9 3 23 4 21 305 42.2 0.3 44.5 41.7 01/19/2006 02:30:00 4.9 0.4 5.7 3.8 4.6 0.4 5.7 3.4 15 3 13 305 42 2.2 44.5 26.4 01/19/2006 02:40:00 5 0.3 6.1 4.2 4.7 0.4 5.7 3.8 17 4 16 305 42.3 1.1 44.5 39.6 01/19/2006 02:50:00 4.5 0.4 5.3 3.4 4.1 0.4 4.9 3 18 4 16 305 42.6 1 44.5 40.3 01/19/2006 03:00:00 4.9 0.4 6.1 3.8 4.6 0.4 5.3 3.4 18 3 19 305 42.8 0.6 44.1 40.3 01/19/2006 03:10:00 5.3 0.4 6.1 4.2 5 0.4 6.1 4.2 21 3 27 305 40.4 1.7 42.7 26.1 01/19/2006 03:20:00 4.8 0.5 5.7 3.4 4.4 0.4 5.3 3 18 3 25 305 40.6 5.2 45.5 21.9 01/19/2006 03:30:00 4.7 0.4 5.7 3.8 4.4 0.5 5.3 3.4 16 4 16 305 41.5 0.9 43.1 33.6 01/19/2006 03:40:00 4.3 0.4 5.3 3 4 0.5 4.9 3 17 3 19 305 39.7 2.4 42 23.4 01/19/2006 03:50:00 4.6 0.5 5.7 3 4.2 0.5 5.3 2.6 17 4 14 305 38.8 0.7 40.6 36.6 01/19/2006 04:00:00 3.8 0.3 4.6 3 3.4 0.4 4.2 2.3 22 5 24 305 38.6 5.2 41.7 10.2 01/19/2006 04:10:00 3.6 0.3 4.6 2.6 3.4 0.3 4.2 2.6 34 9 24 305 39.8 0.5 41.3 37.9 01/19/2006 04:20:00 4.1 0.4 4.9 3.4 3.9 0.4 4.9 3 30 7 19 305 38.3 4.5 41.7 18.4 01/19/2006 04:30:00 4.2 0.2 4.6 3.8 3.9 0.2 4.6 3.4 46 3 44 305 37.9 0.6 39.6 35.3 01/19/2006 04:40:00 3.5 0.3 4.6 2.6 3.4 0.4 4.2 2.3 40 7 54 305 37 0.8 38.9 33.3 01/19/2006 04:50:00 4.1 0.3 4.9 3.4 4.1 0.4 5.3 3 50 6 49 305 36.7 0.4 37.9 35.9 01/19/2006 05:00:00 4.2 0.4 4.9 3.4 4.1 0.4 4.9 3 56 3 54 305 36.5 0.3 37.2 34.9 01/19/2006 05:10:00 3.9 0.3 4.6 3.4 3.7 0.3 4.6 3 57 4 54 305 34.5 0.3 35.9 33.3 01/19/2006 05:20:00 3.9 0.3 4.6 3 3.6 0.4 4.6 2.6 57 4 59 305 35.6 0.4 36.9 34.3 01/19/2006 05:30:00 4.3 0.3 4.9 3.4 4.1 0.3 4.9 3.4 57 3 57 305 35.5 0.3 36.6 33.9 01/19/2006 05:40:00 4.1 0.4 4.9 3.4 4 0.4 4.6 3 51 3 50 305 35.3 1.8 36.6 17.9 01/19/2006 05:50:00 3.5 0.3 4.2 3 3.3 0.3 4.2 2.6 53 3 56 305 35.1 0.4 36.2 33.3 01/19/2006 06:00:00 3.3 0.3 3.8 2.6 3.1 0.3 3.8 2.6 55 3 56 305 33.6 5 37.2 17.3 01/19/2006 06:10:00 3.1 0.3 3.8 2.3 3 0.3 3.8 2.3 46 6 57 305 31.6 6.2 35.9 7.4 01/19/2006 06:20:00 3.5 0.4 4.2 2.3 3.4 0.4 4.2 2.3 51 6 53 305 25.3 6.2 37.9 5.9 01/19/2006 06:30:00 3.6 0.4 4.6 3 3.5 0.4 4.6 2.6 48 6 56 305 33.1 4.4 38.6 26.1 01/19/2006 06:40:00 3.7 0.3 4.6 3 3.6 0.3 4.6 3 50 6 58 305 35.3 4.5 44.8 26.7 01/19/2006 06:50:00 3.6 0.2 4.2 3 3.5 0.3 4.2 3 53 4 54 305 37.9 5.2 43.8 26.7 01/19/2006 07:00:00 3.9 0.3 4.6 3.4 3.8 0.3 4.6 3 53 3 54 305 37.7 6.2 44.5 7.2 01/19/2006 07:10:00 4 0.3 4.9 3.4 3.9 0.3 4.6 3.4 54 3 53 305 38.8 3.7 43.8 10.5 01/19/2006 07:20:00 4.3 0.5 5.3 3 4.2 0.5 5.3 2.6 55 4 59 305 39.5 2.3 43.8 35.3 01/19/2006 07:30:00 3.6 0.3 4.6 2.6 3.4 0.3 4.6 2.6 60 7 64 305 40.1 2.3 44.1 36.6 01/19/2006 07:40:00 3.7 0.3 4.2 3 3.6 0.3 4.2 3 51 9 41 305 41.2 1.6 43.8 36.6 01/19/2006 07:50:00 3.5 0.3 4.2 2.6 3.3 0.4 4.2 2.6 54 8 65 305 35.8 3.5 42 20.1 01/19/2006 08:00:00 3.4 0.3 4.6 2.6 3.1 0.3 3.8 2.3 46 14 63 305 35.4 4.2 39.6 27.3 01/19/2006 08:10:00 3 0.4 3.8 2.3 2.8 0.4 3.4 1.9 51 13 65 305 36.7 3.4 39.3 27.9 01/19/2006 08:20:00 3.2 0.3 3.8 2.6 3.1 0.2 3.8 2.6 54 15 48 305 35.5 5.2 43.8 27.3 01/19/2006 08:30:00 3.6 0.3 4.2 3 3.5 0.2 4.2 2.6 54 6 62 305 40.5 2.4 43.8 34.9 01/19/2006 08:40:00 3.6 0.2 4.2 3 3.6 0.2 3.8 3 49 3 45 305 37.9 2.4 42.7 34.9 01/19/2006 08:50:00 3 0.3 3.8 2.3 3 0.3 3.8 2.3 45 6 49 305 38.6 2.3 42 35.3 01/19/2006 09:00:00 3.4 0.4 4.6 2.6 3.4 0.4 4.2 2.6 51 7 57 305 38 2.3 42 33.9 01/19/2006 09:10:00 3.9 0.3 4.6 3 3.9 0.3 4.6 2.6 40 2 40 305 37.3 2.3 42 34.3 01/19/2006 09:20:00 3.3 0.3 4.2 2.6 3.2 0.3 4.2 2.3 54 8 64 305 37.5 2.2 41.7 35.3 01/19/2006 09:30:00 3.8 0.3 4.6 2.6 3.6 0.4 4.2 2.6 52 4 53 305 34.9 8 44.5 19 01/19/2006 09:40:00 3.8 0.3 4.6 3 3.7 0.3 4.2 2.6 47 4 48 305 37.8 5.6 44.1 21.3 01/19/2006 09:50:00 2.6 0.4 3.4 1.9 2.3 0.4 3 1.5 53 6 54 305 37.5 6.2 45.2 21.9 01/19/2006 10:00:00 2.8 0.3 3.4 2.3 2.7 0.3 3.4 1.9 59 5 53 305 37 3.7 42 22.5 01/19/2006 10:10:00 3.4 0.2 4.2 2.6 3.3 0.2 3.8 2.6 34 11 35 305 36.7 4.2 42.4 21.6 01/19/2006 10:20:00 2.3 0.6 3.4 1.1 2.1 0.6 3.4 0.7 57 20 25 305 37.8 1.5 40.6 35.3 01/19/2006 10:30:00 1.9 0.3 2.6 1.1 1.6 0.4 2.6 0.4 59 7 61 305 36.6 1.5 40 34.9 01/19/2006 10:40:00 2 0.2 2.6 1.5 1.6 0.2 2.3 1.1 55 7 60 305 37.1 1.7 40.3 34.6 01/19/2006 10:50:00 1.7 0.2 2.3 1.1 1.3 0.2 1.9 0.7 48 2 44 305 37.5 1.3 40 33.3 01/19/2006 11:00:00 2.2 0.2 2.6 1.9 2 0.2 2.6 1.5 43 5 50 305 36.5 1.9 40.3 24.9 01/19/2006 11:10:00 2.1 0.2 2.3 1.9 2 0.2 2.3 1.5 31 3 41 305 34.7 3.8 40.6 25.5 01/19/2006 11:20:00 1.7 0.2 2.3 1.1 1.6 0.2 2.3 1.1 26 5 33 305 30.7 6.2 40.6 19.6 01/19/2006 11:30:00 1.3 0.3 1.9 0.7 1.1 0.3 1.5 0.4 10 2 9 305 36.1 2.9 41.7 20.1 01/19/2006 11:40:00 0.7 0.2 1.1 0.4 0.7 0.2 1.1 0.4 31 21 51 305 29.1 5.9 40.6 14.8 01/19/2006 11:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 51 0 51 305 25.5 2.8 28.2 19.6 01/19/2006 12:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 51 0 51 305 21.7 2.1 29.2 20.1 01/19/2006 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 0 305 305 29.7 5.6 40.3 20.7 01/19/2006 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 0 305 305 39.6 3.2 43.8 21.3 01/19/2006 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 0 305 305 38.6 3.7 43.1 21.3 01/19/2006 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 0 305 305 38.4 2.9 42.4 30.1 01/19/2006 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 0 305 305 39.9 2.6 42.7 29.8 01/19/2006 13:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 19 33 345 305 37.9 4.5 43.8 17.3 01/19/2006 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 305 305 34.3 2.4 37.2 17.3 01/19/2006 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 305 305 34.8 3.1 36.6 17.9 01/19/2006 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 305 305 36.6 4.7 41.7 18.4 01/19/2006 13:40:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 65 22 71 305 36.8 0.4 37.6 34.9 01/19/2006 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 71 0 305 305 34.1 8.7 43.8 -22.5 01/19/2006 14:00:00 0.4 0.1 0.7 0.4 0.5 0.4 1.9 0.4 20 12 19 305 32 4.2 36.9 1.7 01/19/2006 14:10:00 0.4 0.1 0.7 0.4 0.5 0.2 1.5 0.4 14 2 12 305 26.8 8 38.6 -0.8 01/19/2006 14:20:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 17 0 17 305 30.6 6.4 40.6 3.7 01/19/2006 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 0 305 305 33.1 4.7 39.6 3.4 01/19/2006 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 0 305 305 24.4 9.9 39.6 8.7 01/19/2006 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 0 305 305 19.9 6.4 31.4 -23 01/19/2006 15:00:00 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 271 51 247 305 21.4 6.2 29.2 12.9 01/19/2006 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 0 305 305 14.2 2.9 19 -22.2 01/19/2006 15:20:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 247 0 247 305 16.7 9.9 28.5 -21.3 01/19/2006 15:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 247 0 247 305 12 8 26.7 -21 01/19/2006 15:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 319 98 247 305 19.9 7.6 34.9 11.6 01/19/2006 15:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 41 32 44 305 25.4 7 34.3 -18.8 01/19/2006 16:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 342 9 4 305 18.8 8.7 34.6 -22.2 01/19/2006 16:10:00 0.8 0.4 1.9 0.4 0.5 0.2 1.9 0.4 349 9 342 305 20.5 8.3 31.7 -22.5 01/19/2006 16:20:00 1.4 0.5 2.6 0.4 0.7 0.4 1.5 0.4 356 11 344 305 28.9 2.6 32 15.3 01/19/2006 16:30:00 1.5 0.4 2.3 0.4 0.8 0.4 1.9 0.4 349 13 337 305 29 4.5 34.6 -22.5 01/19/2006 16:40:00 1.4 0.5 2.3 0.4 0.9 0.4 1.9 0.4 356 9 357 305 29.4 3.1 33.9 18.4 01/19/2006 16:50:00 1.7 0.4 3 0.7 1 0.5 2.3 0.4 355 9 351 305 29.5 3.4 32.6 19 01/19/2006 17:00:00 1.9 0.4 3 1.1 1.3 0.5 2.6 0.4 347 10 349 305 29.9 2.1 32.3 19.3 01/19/2006 17:10:00 2.5 0.3 3.4 1.9 2 0.3 3 1.5 354 5 354 305 30.2 2.2 32 20.1 01/19/2006 17:20:00 1.5 0.5 2.6 0.4 1 0.5 2.3 0.4 353 13 351 305 29.4 2 31.4 20.1 01/19/2006 17:30:00 2.4 0.3 3.8 1.5 1.9 0.4 2.6 0.7 355 5 355 305 29.4 2.4 31.7 19.9 01/19/2006 17:40:00 1.8 0.4 3 1.1 1.3 0.5 2.6 0.4 356 8 355 305 29.4 3.1 32 19.6 01/19/2006 17:50:00 2.2 0.4 3.4 1.1 1.7 0.4 2.6 0.7 4 6 1 305 29.4 2.9 32.3 19.3 01/19/2006 18:00:00 2.2 0.4 3 1.5 1.6 0.4 2.6 0.7 3 7 358 305 29.4 2.7 32 19.3 01/19/2006 18:10:00 1.8 0.4 3 0.7 1.6 0.4 2.6 0.4 5 12 352 305 34.1 7 47.7 18.4 01/19/2006 18:20:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 13 10 2 305 37.1 4.7 42.7 18.1 01/19/2006 18:30:00 1.3 0.3 2.3 0.4 1.1 0.3 1.9 0.4 3 7 2 305 37.6 3.7 43.1 15.3 01/19/2006 18:40:00 1.4 0.3 1.9 0.4 1.1 0.3 1.9 0.4 9 6 8 305 34.8 7 44.1 14.8 01/19/2006 18:50:00 1.3 0.4 2.3 0.4 1 0.3 2.3 0.4 8 10 2 305 37.1 3.2 41.7 14.5 01/19/2006 19:00:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 9 9 27 305 36.4 3.2 40.6 24.6 01/19/2006 19:10:00 1.1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 6 12 9 305 35.8 3.2 40 30.1 01/19/2006 19:20:00 0.5 0.3 1.9 0.4 0.4 0.1 0.7 0.4 10 4 359 305 36.6 2.7 39.6 30.4 01/19/2006 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 356 15 305 305 36.1 3.4 40.3 30.1 01/19/2006 19:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 355 35 326 305 38 3.7 43.8 25.2 01/19/2006 19:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 40 5 38 305 38.8 3.1 42.7 33.3 01/19/2006 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 305 305 38.8 3.1 42.4 32 01/19/2006 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 305 305 39.7 2.8 42.7 33.3 01/19/2006 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 0 305 305 37.7 4.4 42.4 24.6 01/19/2006 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 0 305 305 37.6 3.5 42.4 32.6 01/19/2006 20:40:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 37 0 38 305 35.3 4.2 40.6 24 01/19/2006 20:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 38 0 305 305 33.4 5.2 44.1 22.8 01/19/2006 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 305 305 37.7 3.7 43.8 23.7 01/19/2006 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 305 305 36.2 3.2 40 30.4 01/19/2006 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 305 305 35.7 5 43.1 9.7 01/19/2006 21:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 71 56 305 305 36.4 3.2 41.3 32 01/19/2006 21:40:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 167 0 305 305 37.2 2.7 40.6 31.4 01/19/2006 21:50:00 0.4 0.1 0.7 0.4 0.7 0.2 1.1 0.4 167 0 168 305 37.1 3.2 40.6 31 01/19/2006 22:00:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 167 0 168 305 37.2 3.2 40.6 31.7 01/19/2006 22:10:00 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 167 0 305 305 37.7 3.1 41 31.7 01/19/2006 22:20:00 0.4 0.2 1.1 0.4 0.6 0.2 1.1 0.4 169 6 168 305 37.8 3.2 41.3 31.7 01/19/2006 22:30:00 0.5 0.2 1.1 0.4 0.8 0.2 1.1 0.4 195 3 186 305 38 2.8 41.3 32 01/19/2006 22:40:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 196 0 305 305 38.3 2.7 41 32 01/19/2006 22:50:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 196 0 196 305 38 2.9 41 32 01/19/2006 23:00:00 0.4 0.2 0.7 0.4 0.8 0.3 1.5 0.4 196 0 196 305 38 2.6 40.6 31.7 01/19/2006 23:10:00 0.4 0.1 0.7 0.4 0.9 0.3 1.9 0.4 196 0 196 305 37.4 2.7 40.6 31.7 01/19/2006 23:20:00 0.4 0.1 0.7 0.4 0.9 0.2 1.5 0.4 196 0 196 305 38.4 1.8 40.3 31.7 01/19/2006 23:30:00 0.7 0.2 1.1 0.4 1 0.2 1.5 0.4 196 0 196 305 37.8 2.1 40.3 32 01/19/2006 23:40:00 1.5 0.7 2.6 0.4 1.9 0.9 3 0.4 197 2 196 305 37.9 2.1 40.6 32 01/19/2006 23:50:00 2.4 0.3 3.4 1.9 3 0.2 3.4 2.6 202 2 200 305 36.7 2.9 40.3 29.2 01/20/2006 00:00:00 2.2 0.2 3 1.9 2.6 0.2 3 2.3 202 1 200 305 37.3 1.8 39.6 30.7 01/20/2006 00:10:00 2.4 0.2 2.6 1.9 2.6 0.2 3 2.3 198 5 203 305 37.1 1.8 39.3 30.7 01/20/2006 00:20:00 2 0.2 2.3 1.9 2.2 0.2 2.6 1.9 199 5 191 305 36.7 2.3 40 31.7 01/20/2006 00:30:00 2.1 0.2 2.6 1.9 2.4 0.2 3 1.9 200 1 200 305 36.8 2.6 40.3 31.7 01/20/2006 00:40:00 2.4 0.2 3 1.9 2.7 0.3 3.4 2.3 196 2 200 305 35 3.2 40 29.2 01/20/2006 00:50:00 2.2 0.2 2.6 1.9 2.4 0.2 3 1.9 189 3 194 305 36 3.1 40.3 31.7 01/20/2006 01:00:00 2.5 0.2 3 2.3 2.8 0.2 3.4 2.3 199 4 206 305 36.8 2.6 40 31.7 01/20/2006 01:10:00 2.7 0.2 3 2.3 3.1 0.3 3.8 2.6 202 3 208 305 36.8 2.1 39.3 31.7 01/20/2006 01:20:00 3 0.2 3.4 2.6 3.3 0.2 3.8 3 195 2 194 305 36.6 3.2 40.6 31.7 01/20/2006 01:30:00 3.1 0.2 3.8 2.3 3.4 0.2 3.8 2.6 198 3 199 305 37.1 3.2 40.3 31.7 01/20/2006 01:40:00 3.2 0.2 3.8 2.6 3.4 0.2 3.8 3 197 3 194 305 37.9 2.9 42 31 01/20/2006 01:50:00 3 0.2 3.4 2.6 3.2 0.2 3.8 3 197 3 197 305 38.4 2.5 41 30.7 01/20/2006 02:00:00 3 0.2 3.4 2.3 3.1 0.2 3.8 2.6 196 4 197 305 38.3 1.5 40 28.8 01/20/2006 02:10:00 2.9 0.3 3.8 2.3 3.1 0.3 3.8 2.3 196 7 190 305 37.6 1.7 39.3 29.8 01/20/2006 02:20:00 2.8 0.2 3 2.3 2.9 0.2 3.4 2.6 206 4 199 305 37.1 1.8 38.6 29.8 01/20/2006 02:30:00 3 0.2 3.8 2.6 3.1 0.3 3.8 2.6 208 4 211 305 36.6 2.9 39.6 29.8 01/20/2006 02:40:00 2.9 0.3 3.4 2.3 3.1 0.3 3.8 2.3 203 6 205 305 36 3.2 38.6 29.2 01/20/2006 02:50:00 2.6 0.3 3.4 1.9 2.9 0.2 3.4 2.3 202 9 205 305 37.8 1.8 39.6 29.5 01/20/2006 03:00:00 2.5 0.2 3 1.9 2.8 0.2 3.4 2.3 205 8 190 305 36.2 3.4 39.3 27.3 01/20/2006 03:10:00 2.2 0.2 2.6 1.9 2.5 0.2 3 1.9 205 8 208 305 36.8 3.7 43.8 23.7 01/20/2006 03:20:00 1.8 0.3 2.3 1.1 2.3 0.2 2.6 1.9 214 9 206 305 38.7 2.7 43.4 24.9 01/20/2006 03:30:00 2 0.5 3 0.4 2.4 0.5 3.4 0.4 210 11 218 305 38.8 3.2 43.8 26.4 01/20/2006 03:40:00 2 0.3 2.6 0.7 2.3 0.3 3 1.5 214 11 221 305 36.7 3.1 40.6 28.8 01/20/2006 03:50:00 1.7 0.4 2.6 0.7 1.9 0.3 2.6 1.1 219 12 219 305 36.3 2.5 39.3 29.5 01/20/2006 04:00:00 1.5 0.3 2.3 0.7 1.6 0.3 2.3 1.1 210 12 213 305 35.8 2.4 38.6 28.5 01/20/2006 04:10:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.4 223 12 225 305 36.3 2.2 41.3 29.2 01/20/2006 04:20:00 1.3 0.2 2.3 0.7 1.5 0.2 1.9 0.7 227 11 221 305 36.4 2.6 39.6 29.5 01/20/2006 04:30:00 1.3 0.2 1.9 0.7 1.4 0.3 1.9 0.4 232 11 224 305 35.7 2.6 39.3 28.8 01/20/2006 04:40:00 1.3 0.3 2.3 0.7 1.4 0.3 2.3 0.7 225 12 248 305 36.2 2.9 39.3 28.5 01/20/2006 04:50:00 1.1 0.3 1.9 0.4 1.2 0.3 1.9 0.4 232 13 232 305 35.4 3.4 39.6 21.3 01/20/2006 05:00:00 1.1 0.4 2.3 0.4 1.1 0.3 1.9 0.4 232 15 239 305 35.6 3.1 38.9 28.5 01/20/2006 05:10:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 234 11 256 305 35.9 3.2 40.3 21.3 01/20/2006 05:20:00 1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 218 9 214 305 35.8 3.8 40.3 22.8 01/20/2006 05:30:00 1 0.4 2.3 0.4 1.1 0.3 1.9 0.4 216 6 221 305 33.5 7 45.2 9.5 01/20/2006 05:40:00 0.8 0.4 1.9 0.4 0.8 0.4 2.3 0.4 223 18 219 305 35.7 6.2 42.4 20.4 01/20/2006 05:50:00 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 209 15 233 305 34.5 6.4 43.1 9.5 01/20/2006 06:00:00 0.6 0.2 1.1 0.4 0.7 0.3 1.5 0.4 213 11 225 305 36.4 4.5 41.3 9.2 01/20/2006 06:10:00 1 0.3 1.5 0.4 1.2 0.2 1.9 0.7 205 7 203 305 35.9 5.2 42 9.5 01/20/2006 06:20:00 1 0.2 1.9 0.4 1.2 0.2 1.9 0.4 229 7 225 305 40.5 2.4 43.8 31.7 01/20/2006 06:30:00 0.9 0.2 1.5 0.4 1 0.2 1.5 0.4 239 11 220 305 40 2.6 43.4 31.7 01/20/2006 06:40:00 0.9 0.2 1.5 0.4 0.8 0.2 1.1 0.4 254 5 252 305 38.2 2.9 42 32.3 01/20/2006 06:50:00 0.5 0.2 0.7 0.4 0.8 0.2 1.1 0.4 243 9 246 305 39 6.4 46.3 9.7 01/20/2006 07:00:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 207 8 208 305 40.7 1.8 43.1 34.6 01/20/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 201 0 305 305 40.2 2.2 43.1 34.3 01/20/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 201 0 305 305 40 1.9 43.1 34.3 01/20/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 201 0 305 305 40.2 1.4 42.4 34.3 01/20/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 232 32 305 305 40.1 1.4 42 34.3 01/20/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 305 305 38.9 2.9 43.1 34.3 01/20/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 305 305 40.1 1.7 42.4 34.3 01/20/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 305 305 39.5 1.4 41.7 33.9 01/20/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 305 305 39 2.7 42.7 33.9 01/20/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 305 305 39.4 2.1 43.1 33.9 01/20/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 305 305 39.1 2.5 42 33.6 01/20/2006 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 1 305 305 37.7 3.2 42.4 33.9 01/20/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 305 305 39.2 2.9 42.4 33.9 01/20/2006 09:10:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 263 0 263 305 39.3 2.8 42.7 32.3 01/20/2006 09:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 263 0 305 305 39.4 2.7 43.1 34.3 01/20/2006 09:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 263 0 305 305 40 4 51.8 34.3 01/20/2006 09:40:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 341 32 12 305 43.6 4.2 52.5 33.9 01/20/2006 09:50:00 1 0.4 2.3 0.4 1.2 0.6 3 0.7 29 18 50 305 43.4 3.5 48.8 33.9 01/20/2006 10:00:00 2.4 0.4 3 1.5 2.7 0.3 3 1.9 44 3 45 305 45.7 4.5 52.5 33.6 01/20/2006 10:10:00 2.6 0.4 3.8 1.9 2.9 0.5 4.2 1.9 53 7 55 305 44 4.4 52.9 33.9 01/20/2006 10:20:00 2.6 0.4 3.8 1.9 2.4 0.4 3.4 1.9 70 9 68 305 44.4 3.2 50.3 33.6 01/20/2006 10:30:00 3 0.3 3.8 2.3 2.6 0.3 3.4 1.9 74 8 69 305 45.4 4 48.8 32.6 01/20/2006 10:40:00 3.8 0.4 4.6 2.3 3.3 0.4 4.2 2.3 72 4 67 305 43.9 5 50.3 33.6 01/20/2006 10:50:00 4 0.3 4.6 3 3.4 0.3 4.2 2.6 82 6 86 305 41.8 3.7 49.9 31.7 01/20/2006 11:00:00 3.9 0.3 4.6 3 3.3 0.3 4.2 2.3 80 4 81 305 44.8 4 50.6 34.3 01/20/2006 11:10:00 4.1 0.3 4.9 3.4 3.5 0.3 4.6 2.6 72 6 74 305 42.6 4.5 49.9 34.3 01/20/2006 11:20:00 3.9 0.3 4.6 3 3.7 0.3 4.6 2.6 64 4 67 305 42.6 3.8 49.5 34.6 01/20/2006 11:30:00 4.1 0.3 4.9 3.4 4 0.3 4.6 3.4 67 4 75 305 44 2.8 51.8 34.3 01/20/2006 11:40:00 4.1 0.3 4.9 3 3.9 0.3 4.9 3 65 5 71 305 44.7 6.4 52.9 32 01/20/2006 11:50:00 4.1 0.2 4.6 3.4 4.1 0.3 4.6 3 49 4 55 305 43.7 5.9 52.9 34.3 01/20/2006 12:00:00 3.6 0.3 4.2 3 3.7 0.3 4.6 3 51 3 47 305 47.9 3.7 52.9 33.6 01/20/2006 12:10:00 3 0.3 3.8 2.3 3 0.4 3.8 2.3 53 4 56 305 46.3 5 52.9 33.6 01/20/2006 12:20:00 2.6 0.3 3 1.9 2.5 0.3 3 1.9 56 5 58 305 41.2 6.2 52.1 33.3 01/20/2006 12:30:00 2.3 0.2 3 1.9 2.1 0.2 2.6 1.9 54 3 50 305 39.5 4.5 48.8 33.6 01/20/2006 12:40:00 1.8 0.3 2.3 0.7 1.5 0.3 2.3 0.7 52 4 59 305 42.1 4.2 50.3 33.6 01/20/2006 12:50:00 1 0.3 1.9 0.4 0.4 0.1 1.1 0.4 46 9 37 305 43.7 3.4 50.3 33.6 01/20/2006 13:00:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 33 13 51 305 39.7 4.5 48.4 33.6 01/20/2006 13:10:00 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 36 3 35 305 37.2 3.8 43.4 16.5 01/20/2006 13:20:00 1.6 0.2 2.3 1.1 1 0.4 1.5 0.4 38 6 45 305 38.3 3.7 44.5 22.2 01/20/2006 13:30:00 1.8 0.2 2.3 1.5 1.4 0.3 1.9 0.4 47 2 50 305 36.9 3.2 43.4 29.8 01/20/2006 13:40:00 2 0.2 2.3 1.5 1.8 0.3 2.3 1.1 50 2 48 305 38.4 4.4 46.3 30.4 01/20/2006 13:50:00 2.1 0.3 2.6 1.5 1.7 0.2 2.3 1.1 54 4 55 305 39 3.5 46.6 30.7 01/20/2006 14:00:00 2.6 0.2 3 1.9 1.9 0.3 2.6 1.1 59 4 57 305 37.7 7.6 50.6 12.9 01/20/2006 14:10:00 2.3 0.3 3 1.5 1.9 0.3 2.6 1.1 63 3 65 305 36.1 5.6 52.9 7.7 01/20/2006 14:20:00 2.3 0.2 2.6 1.9 2 0.2 2.6 1.5 67 2 70 305 39.4 9.9 52.9 -19 01/20/2006 14:30:00 2.1 0.2 2.6 1.9 2 0.2 2.3 1.5 69 3 62 305 30.6 9.1 48.8 -19.9 01/20/2006 14:40:00 2.1 0.2 2.3 1.9 1.9 0.2 2.3 1.5 59 3 63 305 36.9 12.3 52.9 -2.7 01/20/2006 14:50:00 2.1 0.2 2.6 1.9 1.9 0.2 2.3 1.5 61 2 58 305 31 7 40.6 3.9 01/20/2006 15:00:00 2.1 0.2 2.6 1.5 1.8 0.2 2.3 1.5 61 2 62 305 29.5 16 48.4 -21.3 01/20/2006 15:10:00 2 0.2 2.6 1.5 1.8 0.2 2.3 1.1 56 2 57 305 25.6 7.6 40.3 -21 01/20/2006 15:20:00 1.8 0.2 2.3 1.1 1.5 0.3 2.3 1.1 52 3 52 305 18.6 7.6 30.4 -20.6 01/20/2006 15:30:00 2.1 0.2 2.6 1.9 2.1 0.2 2.6 1.5 53 3 50 305 16.6 15.3 30.7 -21 01/20/2006 15:40:00 2.2 0.2 2.6 1.9 2.2 0.2 2.6 1.9 59 4 57 305 21.8 10.8 29.8 -20.8 01/20/2006 15:50:00 2.1 0.2 2.3 1.9 2.1 0.2 2.6 1.5 55 4 67 305 23.5 10.4 34.9 -20.8 01/20/2006 16:00:00 2.2 0.2 2.6 1.9 2.2 0.2 2.6 1.9 50 4 57 305 17.2 2.4 20.1 -21 01/20/2006 16:10:00 2.5 0.2 3 1.9 2.5 0.3 3 1.9 44 4 46 305 15.9 3.2 22.2 -20.1 01/20/2006 16:20:00 2.4 0.2 3 1.9 2.4 0.2 3 1.9 41 4 41 305 16.6 4.7 19.6 -19.2 01/20/2006 16:30:00 2.3 0.2 3 1.9 2.3 0.2 2.6 1.9 43 5 40 305 22.9 5 35.3 11.8 01/20/2006 16:40:00 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.5 44 6 49 305 40.5 12.9 51.8 -17.9 01/20/2006 16:50:00 1.5 0.3 2.3 1.1 1.5 0.3 2.3 0.7 38 2 36 305 46.6 10.8 51.8 -17.9 01/20/2006 17:00:00 1.2 0.2 1.5 0.7 1.1 0.2 1.5 0.7 37 0 37 305 52 1.8 52.9 32 01/20/2006 17:10:00 1.2 0.2 1.9 0.7 1.2 0.2 1.9 0.7 37 0 37 305 52.7 0.2 52.9 49.2 01/20/2006 17:20:00 1.4 0.3 1.9 0.7 1.4 0.2 1.9 1.1 48 5 37 305 52.7 0 52.9 52.9 01/20/2006 17:30:00 0.9 0.2 1.1 0.4 1 0.2 1.5 0.7 44 12 51 305 51.5 2.7 52.9 36.9 01/20/2006 17:40:00 0.8 0.2 1.1 0.4 1 0.2 1.5 0.7 27 10 21 305 52.7 0 52.9 52.9 01/20/2006 17:50:00 1 0.4 1.9 0.4 1.1 0.3 1.9 0.4 19 9 16 305 52.7 0 52.9 52.9 01/20/2006 18:00:00 1.4 0.3 2.3 0.4 1.3 0.3 2.3 0.4 16 9 34 305 52.7 0.2 52.9 49.5 01/20/2006 18:10:00 1.4 0.2 1.9 0.7 1.2 0.2 1.9 0.7 4 6 5 305 51.8 3.1 52.9 32.6 01/20/2006 18:20:00 1.2 0.3 1.9 0.4 0.7 0.3 1.5 0.4 359 4 357 305 52.4 0.4 52.9 50.3 01/20/2006 18:30:00 1 0.3 1.5 0.4 0.4 0.2 1.1 0.4 354 9 3 305 52.2 2.8 52.9 33.3 01/20/2006 18:40:00 0.9 0.3 1.5 0.4 0.4 0.1 0.7 0.4 344 0 344 305 52.7 0 52.9 52.9 01/20/2006 18:50:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 342 1 341 305 52.7 0 52.9 52.9 01/20/2006 19:00:00 0.9 0.2 1.5 0.4 0.4 0.1 0.7 0.4 342 4 340 305 52.7 0.3 52.9 47.7 01/20/2006 19:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.5 0.4 354 15 343 305 52.7 0 52.9 52.9 01/20/2006 19:20:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 359 10 18 305 52.7 0.2 52.9 48.8 01/20/2006 19:30:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 332 22 315 305 52.7 0 52.9 52.9 01/20/2006 19:40:00 0.8 0.4 1.9 0.4 0.4 0.1 0.7 0.4 315 5 313 305 52.7 0 52.9 52.9 01/20/2006 19:50:00 1.4 0.4 2.3 0.4 0.6 0.3 1.5 0.4 313 19 306 305 52.7 0 52.9 52.9 01/20/2006 20:00:00 2 0.4 3 1.1 1.1 0.5 2.3 0.4 317 22 310 305 52.7 0 52.9 52.9 01/20/2006 20:10:00 2.4 0.5 3 1.1 1.3 0.6 2.6 0.4 322 8 320 305 52.2 0.3 52.9 51 01/20/2006 20:20:00 2.5 0.3 3 1.5 1.7 0.3 2.3 0.7 329 4 325 305 50.7 1.4 52.9 46.6 01/20/2006 20:30:00 2 0.2 2.6 1.5 1.5 0.3 2.3 0.7 337 3 337 305 52.4 0.7 52.9 49.2 01/20/2006 20:40:00 1.4 0.4 2.3 0.4 0.8 0.4 1.9 0.4 352 13 345 305 52.6 0.3 52.9 50.3 01/20/2006 20:50:00 1.2 0.4 1.9 0.4 0.8 0.3 1.5 0.4 353 12 353 305 52.5 0.4 52.9 49.9 01/20/2006 21:00:00 1.5 0.3 2.3 0.4 1 0.3 1.9 0.4 347 7 344 305 51.7 1.1 52.9 46.3 01/20/2006 21:10:00 1.8 0.2 2.3 1.1 1.1 0.3 1.9 0.4 354 4 354 305 51.1 1.2 52.9 48.1 01/20/2006 21:20:00 2.2 0.2 2.6 1.5 1.6 0.4 2.3 0.7 346 1 346 305 51.1 1 52.9 47.3 01/20/2006 21:30:00 2.2 0.2 2.6 1.5 1.7 0.4 2.3 0.7 344 3 342 305 52 0.9 52.9 48.1 01/20/2006 21:40:00 2.1 0.2 2.6 1.5 1.7 0.3 2.3 0.7 349 2 347 305 52.3 0.5 52.9 49.5 01/20/2006 21:50:00 1.8 0.2 2.3 1.5 1.7 0.2 2.3 1.1 346 4 350 305 52.5 0.4 52.9 48.8 01/20/2006 22:00:00 1.8 0.2 2.3 1.1 1.5 0.3 2.3 0.4 336 3 341 305 44.6 9.1 52.9 30.4 01/20/2006 22:10:00 1.5 0.6 2.3 0.4 0.9 0.5 1.9 0.4 328 8 330 305 42 8 52.9 30.7 01/20/2006 22:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 24 17 347 305 52.7 0.3 52.9 46.6 01/20/2006 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 0 305 305 52.7 0 52.9 52.9 01/20/2006 22:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 33 0 33 305 52.7 0 52.9 52.9 01/20/2006 22:50:00 0.5 0.2 0.7 0.4 0.5 0.2 1.1 0.4 33 0 33 305 52.7 0 52.9 52.9 01/20/2006 23:00:00 1.2 0.4 1.9 0.4 1.3 0.3 1.9 0.7 55 9 54 305 52.3 0.8 52.9 42 01/20/2006 23:10:00 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 54 1 54 305 52.5 1.3 52.9 39.3 01/20/2006 23:20:00 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.7 58 4 54 305 52.6 0.2 52.9 50.3 01/20/2006 23:30:00 1.3 0.2 1.5 0.7 1.2 0.2 1.5 0.7 61 0 61 305 52.1 0.7 52.9 48.4 01/20/2006 23:40:00 1.3 0.2 1.9 0.7 1.3 0.2 1.5 0.7 61 2 61 305 50.3 1 52.9 48.4 01/20/2006 23:50:00 1.4 0.2 1.9 1.1 1.4 0.1 1.9 1.1 48 1 48 305 52.3 0.2 52.9 51.8 01/21/2006 00:00:00 1.8 0.2 2.3 1.5 1.8 0.2 2.3 1.1 47 0 48 305 49.5 8.3 52.9 23.7 01/21/2006 00:10:00 1.7 0.2 1.9 1.5 1.8 0.2 1.9 1.5 48 2 47 305 39.7 10.8 52.5 26.4 01/21/2006 00:20:00 1.8 0.2 2.3 1.1 1.9 0.2 2.3 1.5 42 3 41 305 48.1 3.2 52.9 25.8 01/21/2006 00:30:00 1.9 0.2 2.3 1.5 2 0.2 2.6 1.5 41 1 41 305 48 5.4 52.9 26.1 01/21/2006 00:40:00 1.9 0.2 2.6 1.5 2.1 0.2 2.6 1.5 47 3 47 305 48.8 2.9 52.9 27.3 01/21/2006 00:50:00 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.5 51 2 52 305 47 3.8 52.9 26.4 01/21/2006 01:00:00 2.2 0.2 2.6 1.9 2.3 0.2 2.6 1.9 49 5 53 305 46 6.4 52.9 24.9 01/21/2006 01:10:00 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.5 46 4 47 305 45.9 6.2 52.1 24.6 01/21/2006 01:20:00 2.1 0.2 2.6 1.9 2.2 0.2 2.6 1.9 44 3 52 305 50.3 3.8 52.9 29.2 01/21/2006 01:30:00 2.6 0.5 3.4 1.5 2.8 0.5 3.8 1.9 48 5 56 305 51.8 2.4 52.9 44.1 01/21/2006 01:40:00 3.5 0.3 3.8 2.6 3.7 0.2 4.2 3 54 2 51 305 46.3 2.4 52.9 43.1 01/21/2006 01:50:00 3.7 0.2 4.2 3.4 3.9 0.2 4.2 3.4 54 3 56 305 48.5 2.6 52.9 44.5 01/21/2006 02:00:00 3.6 0.2 4.2 3 3.8 0.2 4.6 3.4 49 2 45 305 49.2 3.4 52.9 43.1 01/21/2006 02:10:00 3.8 0.1 4.2 3.4 4 0.2 4.6 3.8 46 1 45 305 50.5 3.2 52.9 40.3 01/21/2006 02:20:00 3.8 0.2 4.2 3.4 4 0.2 4.2 3.4 52 3 47 305 52.2 1.7 52.9 42.7 01/21/2006 02:30:00 3.2 0.4 3.8 2.3 3.2 0.4 4.2 2.3 53 4 55 305 52.1 1.8 52.9 43.8 01/21/2006 02:40:00 2.2 0.4 3 1.5 2.2 0.4 3 1.5 39 6 51 305 51.8 2.6 52.9 41.7 01/21/2006 02:50:00 1.8 0.2 2.3 1.5 1.9 0.2 2.3 1.5 39 3 36 305 51.3 2.9 52.9 42.4 01/21/2006 03:00:00 1.7 0.2 2.3 1.1 1.8 0.2 2.3 1.5 24 11 32 305 49.4 4.4 52.9 40.3 01/21/2006 03:10:00 2 0.2 2.6 1.5 1.9 0.2 2.6 1.5 16 4 18 305 51.9 2 52.9 45.2 01/21/2006 03:20:00 1.9 0.2 2.3 1.5 1.7 0.2 1.9 1.1 16 4 18 305 48.8 2.4 52.9 45.5 01/21/2006 03:30:00 2.3 0.4 3 1.5 2 0.4 2.6 1.5 20 4 18 305 50.4 2.9 52.9 44.8 01/21/2006 03:40:00 2.7 0.2 3 2.3 2.4 0.2 3 1.9 18 2 19 305 50.5 3.4 52.9 39.3 01/21/2006 03:50:00 2.8 0.3 3.4 1.9 2.5 0.3 3 1.9 18 3 19 305 47.5 3.5 52.9 39.6 01/21/2006 04:00:00 3 0.2 3.4 2.6 3 0.2 3.4 2.3 41 12 22 305 51.9 2 52.9 45.9 01/21/2006 04:10:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.6 54 3 57 305 51.9 2.1 52.9 45.5 01/21/2006 04:20:00 3.8 0.2 4.9 3.4 3.6 0.3 4.2 2.6 57 3 53 305 48.9 3.1 52.9 45.2 01/21/2006 04:30:00 3.8 0.3 4.6 3 3.9 0.3 4.6 3.4 55 4 53 305 46.9 0 47.7 46.6 01/21/2006 04:40:00 3.8 0.3 4.6 3.4 3.8 0.4 4.6 3 59 4 53 305 50.1 2.8 52.9 45.5 01/21/2006 04:50:00 3.8 0.4 4.6 3 3.5 0.3 4.2 2.6 65 4 61 305 49.5 2.8 52.9 46.3 01/21/2006 05:00:00 2.7 0.6 3.8 1.5 2.5 0.5 3.8 1.5 71 9 66 305 49.1 1.8 52.1 46.3 01/21/2006 05:10:00 2 0.4 3 1.1 1.9 0.3 3 0.7 71 12 85 305 50 0.3 51 48.8 01/21/2006 05:20:00 1.7 0.5 2.6 0.4 1.6 0.5 2.6 0.7 76 12 64 305 47 0.9 50.3 45.5 01/21/2006 05:30:00 1 0.4 1.9 0.4 1.1 0.4 2.3 0.4 53 11 51 305 48.4 3.2 52.9 44.5 01/21/2006 05:40:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 83 22 58 305 50 3.7 52.9 36.2 01/21/2006 05:50:00 0.9 0.3 1.5 0.4 0.6 0.3 1.5 0.4 96 10 111 305 48.4 4.4 52.9 42 01/21/2006 06:00:00 1.5 0.3 2.3 0.7 1.5 0.5 2.6 0.4 75 11 58 305 50.5 3.5 52.9 43.8 01/21/2006 06:10:00 1.8 0.5 3 1.1 1.8 0.5 3 1.1 68 12 69 305 51.9 2.2 52.9 44.8 01/21/2006 06:20:00 2 0.2 2.6 1.5 2.2 0.3 2.6 1.5 46 12 62 305 51.9 1.1 52.9 44.8 01/21/2006 06:30:00 2 0.2 2.3 1.5 2 0.2 2.3 1.5 52 9 35 305 52.1 0.1 52.9 51 01/21/2006 06:40:00 2.1 0.3 2.6 1.5 2.2 0.4 3 1.5 48 7 54 305 52 0.3 52.9 45.5 01/21/2006 06:50:00 2.2 0.3 3 1.5 2.3 0.4 3.4 1.5 49 4 47 305 52.3 0 52.9 51.8 01/21/2006 07:00:00 2.8 0.4 4.2 1.5 3.1 0.5 4.6 2.3 48 3 50 305 52 0 52.9 51.8 01/21/2006 07:10:00 3.3 0.3 4.2 2.6 3.6 0.3 4.2 2.6 51 3 54 305 47.3 3.7 52.9 42.7 01/21/2006 07:20:00 3.9 0.3 4.6 3 4.1 0.3 4.6 3 49 3 48 305 47.8 2.8 52.9 43.8 01/21/2006 07:30:00 4 0.2 4.6 3.4 4.2 0.3 4.6 3 54 5 48 305 51.2 2.7 52.9 42.4 01/21/2006 07:40:00 2.9 0.6 4.6 1.5 2.8 0.6 4.6 1.5 60 10 62 305 49.7 3.1 52.9 42 01/21/2006 07:50:00 3.2 0.4 4.2 2.3 3.3 0.5 4.6 2.3 55 7 50 305 51.8 2.7 52.9 41.3 01/21/2006 08:00:00 3 0.5 4.2 1.9 3 0.5 4.2 1.9 60 6 59 305 48.2 4.5 52.9 39.6 01/21/2006 08:10:00 2.5 0.4 3.4 1.5 2.4 0.4 3.4 1.5 62 10 78 305 42.9 2.7 47.7 40.3 01/21/2006 08:20:00 2.6 0.5 3.8 1.5 2.1 0.4 3 0.7 83 15 98 305 50 2.6 52.9 47.3 01/21/2006 08:30:00 3.2 0.5 4.6 1.5 2.3 0.6 3.8 0.7 82 10 82 305 47.6 4.2 52.9 40.3 01/21/2006 08:40:00 2.8 0.6 4.6 1.1 2.4 0.6 4.2 0.7 81 15 69 305 50.4 0.7 52.9 49.5 01/21/2006 08:50:00 1.6 0.6 3 0.4 1.1 0.5 2.3 0.4 90 27 111 305 50.8 3.1 52.9 41.7 01/21/2006 09:00:00 1.3 0.5 2.6 0.4 0.9 0.6 2.3 0.4 97 27 101 305 52.4 0.5 52.9 48.8 01/21/2006 09:10:00 1.1 0.7 3.4 0.4 0.8 0.6 2.6 0.4 91 76 73 305 52.1 0.6 52.9 50.3 01/21/2006 09:20:00 2.2 0.4 3.4 1.1 1.8 0.5 3 0.4 72 11 62 305 51.4 0.4 52.9 51 01/21/2006 09:30:00 2.7 0.4 3.8 1.5 2.4 0.4 3 1.1 81 11 93 305 52.3 1 52.9 40.6 01/21/2006 09:40:00 2.1 0.5 3 1.1 2 0.4 3 1.1 68 10 71 305 52.4 0.7 52.9 49.5 01/21/2006 09:50:00 1.5 0.4 2.6 0.7 1.4 0.5 2.6 0.4 56 10 57 305 52 1.1 52.9 48.4 01/21/2006 10:00:00 1 0.4 2.3 0.4 0.7 0.3 1.5 0.4 50 8 58 305 48.1 5 52.9 42 01/21/2006 10:10:00 1.4 0.4 2.3 0.4 1.4 0.3 1.9 0.7 47 7 58 305 44.9 1.5 47.3 42 01/21/2006 10:20:00 1.4 0.3 1.9 0.7 1.4 0.3 2.3 0.7 46 8 56 305 45.3 1.4 46.6 42.7 01/21/2006 10:30:00 1.7 0.5 2.6 0.7 1.5 0.4 2.3 0.7 55 9 62 305 45.7 1.1 49.2 44.8 01/21/2006 10:40:00 1.4 0.4 2.3 0.7 1 0.4 1.9 0.4 60 8 57 305 44.6 1.7 48.8 39.3 01/21/2006 10:50:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 45 10 58 305 47.5 3.5 52.9 42.7 01/21/2006 11:00:00 1.6 0.3 2.3 1.1 1.6 0.3 2.3 1.1 52 6 48 305 48.2 2.5 52.9 39.6 01/21/2006 11:10:00 2 0.2 2.6 1.1 1.9 0.2 2.6 1.5 54 8 59 305 51.1 2.6 52.9 41 01/21/2006 11:20:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 50 5 49 305 49.6 4.4 52.9 36.6 01/21/2006 11:30:00 2.6 0.4 3.8 1.5 2.5 0.4 3.4 1.5 50 7 41 305 49.9 2.2 52.9 42.4 01/21/2006 11:40:00 2.7 0.3 3.4 2.3 2.7 0.2 3.4 2.3 45 5 52 305 50.5 2.3 52.9 41.3 01/21/2006 11:50:00 2.6 0.3 3 1.9 2.7 0.2 3.4 1.9 42 6 53 305 51.6 1.8 52.9 41 01/21/2006 12:00:00 2.2 0.3 3 1.5 2.2 0.3 2.6 1.5 36 8 17 305 50.7 2.2 52.9 46.3 01/21/2006 12:10:00 2.3 0.2 3 1.9 2.4 0.2 3 1.9 34 6 36 305 50.1 2.2 52.9 47.3 01/21/2006 12:20:00 1.8 0.2 2.6 1.1 1.9 0.3 3 1.5 28 6 26 305 49.9 2.8 52.9 45.2 01/21/2006 12:30:00 1.3 0.4 1.9 0.4 1.4 0.4 2.3 0.4 23 13 22 305 46.8 0.4 47.7 45.5 01/21/2006 12:40:00 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.4 19 14 12 305 47.8 1 50.3 46.3 01/21/2006 12:50:00 2.1 0.3 3.4 1.1 2 0.3 3.8 1.5 16 8 5 305 48.2 1 49.9 45.9 01/21/2006 13:00:00 2.7 0.9 4.9 0.7 2.6 0.7 4.6 1.1 9 12 353 305 43.3 4.2 48.4 36.9 01/21/2006 13:10:00 6.2 0.8 7.6 3.4 5.8 0.8 7.6 3 15 7 9 305 46.9 4.7 52.9 37.2 01/21/2006 13:20:00 6.6 0.9 8.8 4.9 6.4 0.9 8.4 4.6 12 5 14 305 49.6 2.2 52.9 37.2 01/21/2006 13:30:00 7.5 0.6 8.8 5.7 7.3 0.7 9.1 5.7 7 4 3 305 47.1 2 52.9 32.3 01/21/2006 13:40:00 7.4 0.8 9.1 5.3 7.2 0.8 9.1 5.3 5 5 9 305 40 7.3 50.3 14.5 01/21/2006 13:50:00 8.4 0.9 10.7 6.5 8.2 1.1 11.1 5.7 10 5 12 305 37.2 4.2 43.8 18.1 01/21/2006 14:00:00 9.1 0.7 10.7 7.2 9 0.8 11.1 6.8 8 5 12 305 35.1 6.4 43.1 16.7 01/21/2006 14:10:00 8.5 0.7 10.3 6.8 8.3 0.7 10.3 6.5 14 7 17 305 33.9 6.4 44.5 17.9 01/21/2006 14:20:00 8.2 1.1 11.1 5.7 8.1 1.1 10.7 5.7 9 7 10 305 29.2 6.2 37.9 15.1 01/21/2006 14:30:00 8.9 1 10.7 6.1 8.7 1 10.7 6.1 11 6 8 305 39.1 12.3 52.9 13.2 01/21/2006 14:40:00 8.3 1 9.9 6.1 8.1 1 10.3 5.7 13 6 21 305 48.9 2.2 52.9 44.5 01/21/2006 14:50:00 8.1 1 10.3 5.3 7.9 1 10.3 5.3 15 6 4 305 47.8 1.7 52.9 44.5 01/21/2006 15:00:00 8.2 1 10.7 6.1 8.1 0.9 10.3 6.1 14 6 17 305 47.2 2.9 52.9 41 01/21/2006 15:10:00 9.1 0.7 10.7 6.5 8.9 1 11.1 6.5 11 6 4 305 47.1 2.9 52.9 35.9 01/21/2006 15:20:00 8.9 0.8 10.7 6.8 8.6 0.9 11.1 5.7 11 6 13 305 49.4 2.9 52.9 39.3 01/21/2006 15:30:00 8.3 0.9 9.9 6.1 8 1 9.9 5.3 22 8 13 305 49.1 3.2 52.9 32 01/21/2006 15:40:00 8 0.8 9.5 5.7 7.7 0.8 9.9 5.7 22 8 12 305 49.3 3.5 52.9 30.1 01/21/2006 15:50:00 7.6 1 10.3 5.7 7.3 1 10.7 5.3 14 10 3 305 49.4 3.8 52.9 23.7 01/21/2006 16:00:00 8.4 1 10.7 6.1 8.3 1.2 10.7 5.7 8 6 9 305 49 2.9 52.9 44.5 01/21/2006 16:10:00 7.5 1 9.5 5.3 7.3 1 9.5 5.3 19 6 21 305 51 2.8 52.9 44.5 01/21/2006 16:20:00 8.2 0.8 9.5 6.1 8 0.9 9.9 5.7 16 4 21 305 51.8 2.5 52.9 43.4 01/21/2006 16:30:00 7.9 0.8 9.5 5.3 7.7 0.9 9.9 5.7 14 5 16 305 51 2.8 52.9 45.2 01/21/2006 16:40:00 8.5 0.8 10.3 6.1 8.3 0.9 10.7 6.1 9 5 7 305 51.9 2.2 52.9 43.1 01/21/2006 16:50:00 7.3 0.9 9.1 5.3 7.1 0.9 9.5 4.9 9 9 17 305 52.1 0.9 52.9 43.8 01/21/2006 17:00:00 7.4 1 9.5 5.3 7.3 1 9.9 4.9 4 6 7 305 50.4 2.2 52.9 42 01/21/2006 17:10:00 6.9 0.8 9.1 4.9 6.7 0.9 9.1 4.6 9 7 16 305 48.8 1.5 52.9 42 01/21/2006 17:20:00 8.2 0.7 9.5 5.7 8.1 0.8 9.9 5.7 6 5 7 305 49.2 2.9 52.9 25.8 01/21/2006 17:30:00 8.1 0.7 9.5 5.7 8.1 0.8 9.9 6.1 10 5 3 305 50 1.1 52.9 47.3 01/21/2006 17:40:00 6.1 1.3 8.8 3.4 5.8 1.2 8.4 3 14 7 5 305 50 1.1 52.9 48.1 01/21/2006 17:50:00 4.8 1 7.2 1.9 4.4 1 6.5 1.9 21 15 14 305 50.6 1.5 52.9 47.7 01/21/2006 18:00:00 6.9 0.9 8.8 4.6 6.6 1 8.8 3.8 3 7 7 305 51 1.6 52.9 48.1 01/21/2006 18:10:00 7.7 0.7 9.1 5.7 7.5 0.8 9.5 5.3 7 5 10 305 50.6 1.5 52.9 48.4 01/21/2006 18:20:00 8.5 0.5 9.5 6.5 8.4 0.6 9.9 6.5 358 3 355 305 44.2 6.7 52.9 27.6 01/21/2006 18:30:00 8.1 0.7 9.9 6.5 8.1 0.8 10.3 6.1 3 6 4 305 37.8 4.4 45.2 26.7 01/21/2006 18:40:00 8.7 0.5 9.5 6.8 8.7 0.7 10.3 6.8 6 3 7 305 35.8 4.7 44.5 25.2 01/21/2006 18:50:00 7.7 0.6 9.1 5.7 7.5 0.7 9.5 5.3 5 5 11 305 41.2 7.3 52.9 20.4 01/21/2006 19:00:00 7.3 0.8 8.8 4.2 7 0.8 8.8 4.6 11 6 11 305 38.2 5.2 43.8 8.2 01/21/2006 19:10:00 7.3 0.9 9.5 4.6 6.9 1 9.5 4.2 9 7 7 305 38.4 3.4 43.4 30.1 01/21/2006 19:20:00 7.7 1.1 10.3 4.9 7.3 1.1 10.3 4.6 2 7 359 305 38.1 4.5 44.5 23.4 01/21/2006 19:30:00 8.1 1 10.3 4.9 7.8 1 10.7 4.2 9 6 8 305 38.4 4.7 44.8 6.4 01/21/2006 19:40:00 7.6 1.2 9.9 4.9 7.3 1.2 10.3 4.6 11 6 13 305 33.5 10.8 42.7 -24.4 01/21/2006 19:50:00 6.6 1.2 9.9 3.8 6.4 1.3 9.1 3.8 9 7 10 305 37 5 44.5 24.9 01/21/2006 20:00:00 7.7 1 9.9 4.9 7.4 1 9.9 4.9 10 6 11 305 48.2 7 52.9 27 01/21/2006 20:10:00 8.5 0.8 10.3 6.5 8.3 0.7 9.9 6.5 10 5 10 305 51.2 4 52.9 33 01/21/2006 20:20:00 8.2 0.8 9.9 5.7 8 0.8 9.9 5.7 13 5 18 305 47.3 8 52.9 19.9 01/21/2006 20:30:00 9.1 0.9 10.7 6.5 8.6 1 10.7 6.1 13 5 16 305 48.9 6.7 52.9 20.7 01/21/2006 20:40:00 9.5 0.6 11.1 6.8 9.4 0.8 11.5 7.2 12 5 12 305 49.3 3.2 52.9 39.6 01/21/2006 20:50:00 9.5 0.8 11.5 7.2 9.2 0.9 11.1 6.8 11 4 12 305 49.7 3.2 52.9 36.2 01/21/2006 21:00:00 9 0.8 11.1 6.5 8.7 0.8 11.1 6.5 11 4 6 305 48.2 2.8 52.9 41.3 01/21/2006 21:10:00 9.2 0.7 11.1 6.8 8.9 0.9 11.5 6.8 11 5 7 305 48.6 7.3 52.9 21.3 01/21/2006 21:20:00 9.4 0.9 11.1 5.3 9.2 1.1 11.1 5.7 10 6 19 305 51.5 2.1 52.9 46.3 01/21/2006 21:30:00 8.7 0.8 10.7 6.5 8.5 0.9 10.7 6.1 10 5 5 305 49.6 6.7 52.9 21.6 01/21/2006 21:40:00 9 0.9 11.1 6.8 8.7 0.9 11.1 6.1 13 4 9 305 51 2.4 52.9 44.5 01/21/2006 21:50:00 8.2 0.9 9.9 6.1 8.1 0.9 9.9 5.7 12 4 8 305 48.6 7 52.9 21 01/21/2006 22:00:00 8.8 0.6 10.3 7.2 8.4 0.7 10.7 6.5 11 4 18 305 51.6 2.1 52.9 46.6 01/21/2006 22:10:00 8.1 0.9 9.9 5.7 7.9 0.9 9.9 5.7 11 5 8 305 49.9 6.7 52.9 21.9 01/21/2006 22:20:00 8.1 0.7 9.5 6.1 7.8 0.9 9.9 4.9 9 5 13 305 48.4 7.6 52.9 22.2 01/21/2006 22:30:00 7.6 0.8 9.5 5.3 7.3 0.8 9.5 5.7 16 5 16 305 50.8 4.2 52.9 30.1 01/21/2006 22:40:00 7.4 0.8 9.5 5.3 7 0.8 9.1 4.6 16 6 16 305 49.3 7 52.9 28.8 01/21/2006 22:50:00 7.7 0.7 9.1 6.1 7.4 0.7 9.1 5.7 15 4 12 305 45.5 8.7 52.9 23.1 01/21/2006 23:00:00 7.6 0.7 9.1 4.9 7.3 0.7 9.1 5.3 17 5 24 305 50 3.4 52.9 30.7 01/21/2006 23:10:00 7.7 0.8 9.5 5.7 7.3 0.8 9.1 5.3 17 5 36 305 48.5 2.8 51.4 30.7 01/21/2006 23:20:00 7.3 1.2 10.3 4.6 7 1.1 9.5 4.6 14 7 8 305 49.7 1.9 51.8 43.8 01/21/2006 23:30:00 8.5 1.1 11.5 6.1 8.1 1 11.1 5.3 9 5 7 305 49.3 2.1 51.4 43.4 01/21/2006 23:40:00 9 1 11.1 6.5 8.8 1 11.5 6.1 7 6 13 305 47.9 7 52.9 21.3 01/21/2006 23:50:00 9.4 0.7 11.1 7.2 9.2 0.8 11.8 7.2 5 5 6 305 45.7 7.3 52.9 27.3 01/22/2006 00:00:00 10 0.7 11.8 8 9.8 0.9 11.5 7.2 5 4 8 305 41.8 3.2 48.4 27.6 01/22/2006 00:10:00 9.9 0.8 12.2 7.6 9.7 0.9 11.5 7.6 9 4 10 305 43.9 2.8 48.8 34.9 01/22/2006 00:20:00 9.1 0.7 11.1 7.2 8.9 0.8 11.1 6.5 15 5 22 305 46.2 6.4 52.9 23.1 01/22/2006 00:30:00 8.8 1 11.5 6.5 8.4 1.1 11.5 5.3 15 7 10 305 48.6 4.7 52.9 29.2 01/22/2006 00:40:00 9.6 0.6 11.1 7.6 9.4 0.8 11.5 6.5 8 4 0 305 52.4 1 52.9 48.1 01/22/2006 00:50:00 8.4 0.8 10.7 6.5 8.2 0.8 9.9 6.1 11 5 3 305 52.2 1.2 52.9 47.3 01/22/2006 01:00:00 7.9 0.8 10.3 6.1 7.7 0.8 9.9 5.7 12 6 13 305 51.5 1.5 52.9 45.9 01/22/2006 01:10:00 7.3 0.8 9.1 5.3 7 0.7 9.1 5.3 16 6 14 305 50.4 1.9 52.9 43.8 01/22/2006 01:20:00 7.4 1.7 10.7 3.8 7.2 1.7 10.7 3.8 13 7 18 305 51 1.5 52.5 45.5 01/22/2006 01:30:00 6.4 1.1 9.1 3 6.1 1.2 8.8 3.4 4 8 11 305 48.1 5.9 52.9 27 01/22/2006 01:40:00 6.4 1.1 8.8 3.8 6.3 1 8.8 4.2 357 7 2 305 40.4 3.8 52.9 27.9 01/22/2006 01:50:00 6.7 1 8.8 4.2 6.4 1 8.8 3.8 353 8 359 305 52.2 1.1 52.9 48.8 01/22/2006 02:00:00 6.8 1.1 9.1 4.2 6.5 1.1 9.1 4.2 355 6 355 305 52 1.6 52.9 44.8 01/22/2006 02:10:00 7.3 0.8 9.5 5.3 7.2 0.9 9.1 5.3 354 7 351 305 51.5 2.3 52.9 44.1 01/22/2006 02:20:00 8.6 1.2 10.7 4.9 8.4 1.2 11.1 4.9 358 5 357 305 49.4 2.7 52.9 43.8 01/22/2006 02:30:00 9.1 0.9 11.1 6.8 9 1 11.5 6.1 2 5 2 305 50.5 2.2 52.9 44.5 01/22/2006 02:40:00 9 1 11.1 6.5 8.6 0.9 11.1 6.8 353 6 345 305 51.3 1.8 52.9 45.2 01/22/2006 02:50:00 9.3 1.1 11.5 6.5 9 1.1 11.5 6.1 352 7 341 305 41.5 3.8 52.9 31.4 01/22/2006 03:00:00 9.5 1.5 12.2 5.3 9.3 1.5 12.2 5.3 356 5 1 305 43.3 3.2 50.6 30.7 01/22/2006 03:10:00 10.4 1.1 12.6 7.2 10 1.1 13 6.8 355 5 356 305 44 3.5 50.3 32.3 01/22/2006 03:20:00 10.8 1.3 13.3 7.2 10.6 1.3 13.3 6.8 350 6 336 305 44.7 3.2 50.3 35.3 01/22/2006 03:30:00 10.5 1.2 13 8 10.3 1.2 13.3 7.6 353 6 348 305 45.4 2.8 51 35.3 01/22/2006 03:40:00 9.2 1.1 11.8 6.1 8.9 1.1 12.2 6.1 357 5 1 305 43.9 3.1 51 33.6 01/22/2006 03:50:00 9 1.4 12.2 6.5 8.7 1.4 13 5.7 0 9 351 305 44.7 2.9 50.3 35.3 01/22/2006 04:00:00 7 1 9.5 4.6 6.7 1 9.1 4.6 19 7 12 305 46.2 2.9 52.9 35.9 01/22/2006 04:10:00 7.2 0.7 8.8 5.7 6.8 0.8 8.4 4.9 19 5 18 305 47.3 3.7 52.9 35.9 01/22/2006 04:20:00 7.9 0.7 10.3 6.5 7.7 0.6 9.5 6.1 10 4 8 305 52.4 0.7 52.9 49.5 01/22/2006 04:30:00 7.9 0.8 9.9 5.7 7.6 0.8 9.5 5.7 4 6 8 305 52.3 0.8 52.9 50.3 01/22/2006 04:40:00 7.7 1 9.9 4.9 7.5 1.1 10.3 4.9 359 6 355 305 52.2 0.9 52.9 50.6 01/22/2006 04:50:00 7.7 1.3 11.1 5.3 7.4 1.3 11.5 5.3 0 7 3 305 52 0.9 52.9 49.5 01/22/2006 05:00:00 9.1 1.2 11.5 6.1 8.8 1.2 11.8 5.7 359 5 355 305 51.4 1.4 52.9 46.6 01/22/2006 05:10:00 9.8 1.1 13.3 6.8 9.6 1.1 13 6.5 353 8 357 305 52.2 1 52.9 49.9 01/22/2006 05:20:00 10.1 1 12.2 7.6 9.9 1 12.2 6.8 350 5 345 305 51.7 1.5 52.9 47.7 01/22/2006 05:30:00 8.7 0.9 10.7 6.5 8.5 0.9 11.1 6.5 356 5 353 305 51.1 1.2 52.9 48.1 01/22/2006 05:40:00 6.8 0.9 9.5 4.6 6.5 0.9 8.8 4.6 0 6 0 305 51.5 1.8 52.9 47 01/22/2006 05:50:00 7.1 0.8 8.8 5.3 6.9 0.7 8.8 5.3 1 5 6 305 50.3 2 52.9 46.6 01/22/2006 06:00:00 7.6 0.9 10.3 5.7 7.5 1 10.3 5.7 356 6 349 305 52.2 1.2 52.9 47.3 01/22/2006 06:10:00 7.4 1 10.7 5.3 7.2 1 11.5 5.3 355 6 349 305 52.1 1.1 52.9 48.4 01/22/2006 06:20:00 7.6 1 10.3 5.3 7.5 1 9.9 4.9 0 6 7 305 50.5 0.7 52.9 48.4 01/22/2006 06:30:00 7.5 0.9 9.5 4.9 7.2 1 9.5 4.9 357 6 0 305 52.2 0.8 52.9 50.3 01/22/2006 06:40:00 7.9 1 10.3 5.3 7.6 1 9.9 5.3 355 6 3 305 51.4 1.4 52.9 48.8 01/22/2006 06:50:00 8.4 1.2 10.7 5.3 8.2 1.1 11.1 5.7 354 6 355 305 51.8 1.9 52.9 43.8 01/22/2006 07:00:00 6.3 0.8 8 4.2 6.1 0.8 8.4 3.8 358 7 351 305 49.3 4.2 52.9 40 01/22/2006 07:10:00 5.9 0.9 7.6 3.4 5.7 1 8 3.4 358 7 355 305 49 5.6 52.9 37.6 01/22/2006 07:20:00 8.8 2.2 12.2 4.6 8.5 2.2 12.6 4.6 358 5 358 305 52.3 1.4 52.9 45.5 01/22/2006 07:30:00 9 0.9 11.1 6.8 8.8 1 11.5 6.5 359 6 351 305 52.2 1.7 52.9 44.1 01/22/2006 07:40:00 7.4 0.9 10.3 4.9 7.2 1 10.7 4.9 1 5 352 305 52.7 0 52.9 52.1 01/22/2006 07:50:00 6.5 0.7 8.4 4.6 6.3 0.7 8.4 4.6 7 6 6 305 51.5 2.6 52.9 44.5 01/22/2006 08:00:00 6.9 0.8 8.8 4.6 6.8 0.9 8.8 4.6 357 7 2 305 51.2 2.5 52.9 44.5 01/22/2006 08:10:00 7.1 0.9 9.1 4.9 6.9 0.9 9.5 4.2 353 7 359 305 51.5 2.8 52.9 42.7 01/22/2006 08:20:00 8 0.8 9.9 5.7 7.9 0.8 9.9 5.7 355 5 352 305 49.9 3.5 52.9 41 01/22/2006 08:30:00 8.8 0.9 10.7 6.1 8.7 1 11.1 6.5 358 4 357 305 49.9 3.2 52.9 44.5 01/22/2006 08:40:00 7.4 0.7 9.5 4.9 7.2 0.8 9.5 5.3 0 6 359 305 50.4 3.4 52.9 42.4 01/22/2006 08:50:00 8.1 1 10.7 5.3 8 1 10.7 5.3 358 5 347 305 50.3 3.5 52.9 43.1 01/22/2006 09:00:00 8.6 1 11.5 6.1 8.5 1.1 11.5 5.7 1 6 355 305 50.9 3.5 52.9 42 01/22/2006 09:10:00 7.3 1.1 9.9 4.6 6.9 1.2 10.3 4.2 358 8 358 305 49.1 4 52.9 43.1 01/22/2006 09:20:00 8.1 0.8 9.9 6.5 8 0.7 9.9 6.5 352 7 338 305 49.2 4.5 52.9 40 01/22/2006 09:30:00 8.5 0.7 10.3 6.5 8.3 0.8 10.3 5.7 357 5 355 305 51.6 2.6 52.9 43.1 01/22/2006 09:40:00 5.2 1.1 8 2.6 4.9 1.1 7.6 2.3 359 7 2 305 51.9 1.6 52.9 48.4 01/22/2006 09:50:00 4.2 1 6.5 2.3 4.1 1.1 6.1 1.9 350 10 349 305 51.7 1.8 52.9 47.7 01/22/2006 10:00:00 7.6 0.9 9.1 5.3 7.5 0.9 9.1 4.9 0 6 357 305 51.3 1.9 52.9 47 01/22/2006 10:10:00 6.4 0.8 9.1 4.2 6.1 0.8 8.8 3.8 357 5 359 305 51.7 1.6 52.9 48.4 01/22/2006 10:20:00 5.6 1 7.6 3.8 5.3 1 7.6 3.4 359 7 357 305 52.7 0 52.9 52.9 01/22/2006 10:30:00 7.2 0.5 8.8 5.7 6.9 0.5 8.4 5.3 6 4 2 305 51.8 1.8 52.9 46.3 01/22/2006 10:40:00 6.3 0.7 7.6 4.6 6.1 0.7 7.6 4.2 6 7 9 305 52.2 1.1 52.9 48.1 01/22/2006 10:50:00 5.5 0.8 7.2 3.4 5.4 0.8 7.2 3.4 7 6 10 305 51.7 2.1 52.9 46.3 01/22/2006 11:00:00 6 0.6 7.2 4.6 5.7 0.7 7.2 4.2 17 6 11 305 50.1 2.3 52.9 44.5 01/22/2006 11:10:00 4.8 0.5 6.1 3.4 4.4 0.6 6.1 3 22 6 23 305 50.7 2.5 52.9 45.5 01/22/2006 11:20:00 3.5 0.5 4.9 2.6 3 0.5 4.6 1.9 23 7 21 305 51 2.6 52.9 46.3 01/22/2006 11:30:00 4.4 0.7 6.5 2.6 4.1 0.6 5.7 2.6 21 6 20 305 51.8 2.2 52.9 45.9 01/22/2006 11:40:00 5.3 0.8 6.8 3.4 4.9 0.8 6.8 2.6 10 6 358 305 52.6 0.7 52.9 47 01/22/2006 11:50:00 2.1 0.6 3.8 1.1 1.8 0.4 3.4 0.7 36 13 17 305 41.6 9.9 52.9 27.6 01/22/2006 12:00:00 2.7 0.6 3.8 1.5 2.5 0.4 3.8 1.1 27 12 13 305 34.9 5.2 43.8 23.4 01/22/2006 12:10:00 2.5 0.8 4.6 1.1 2 0.8 4.6 0.7 349 19 353 305 47.8 5 52.9 27.3 01/22/2006 12:20:00 5.8 1.1 9.1 3.4 5.4 1 8.4 3.4 4 8 351 305 47.7 3.7 51.8 37.9 01/22/2006 12:30:00 7.4 0.8 9.1 5.7 7.2 0.8 9.1 5.3 2 6 353 305 48.6 3.8 52.9 38.3 01/22/2006 12:40:00 5.4 0.6 7.2 4.2 5.4 0.6 7.2 3.8 9 5 16 305 40.9 4 50.3 17.9 01/22/2006 12:50:00 6 0.7 7.6 4.6 5.6 0.7 7.2 4.2 6 5 12 305 40 2.8 43.4 34.3 01/22/2006 13:00:00 5.1 0.6 6.5 3.4 4.8 0.7 6.1 3 14 6 17 305 39.6 3.8 44.5 33.3 01/22/2006 13:10:00 4.5 0.6 6.5 3 4.2 0.6 6.1 2.6 10 5 5 305 37.8 4 44.1 32.6 01/22/2006 13:20:00 4.7 0.5 6.5 3.4 4.3 0.5 5.7 3.4 11 6 5 305 35.2 0.9 36.6 33 01/22/2006 13:30:00 5.2 0.7 6.8 3.8 4.8 0.7 6.5 3 8 5 4 305 34.6 0.7 35.9 32.3 01/22/2006 13:40:00 4.8 0.9 6.8 3 4.5 0.9 7.2 2.6 4 7 9 305 34.8 0.8 36.6 32.6 01/22/2006 13:50:00 6.4 0.5 7.6 5.3 6.2 0.6 7.6 4.6 358 3 358 305 33.1 3.2 36.9 16.7 01/22/2006 14:00:00 4.8 1.2 8 2.3 4.6 1.2 7.6 1.9 4 9 355 305 34.1 1 36.6 30.4 01/22/2006 14:10:00 5.8 0.6 7.2 3.8 5.5 0.7 7.2 3.8 14 6 3 305 34.3 1.2 36.9 26.4 01/22/2006 14:20:00 5.5 0.7 7.6 3.8 5.3 0.6 6.8 4.2 11 6 6 305 33.7 1.5 36.6 27 01/22/2006 14:30:00 5.6 0.5 6.8 4.2 5.3 0.5 6.5 4.2 11 5 9 305 33.6 3.8 37.2 5.4 01/22/2006 14:40:00 4.5 0.5 5.7 3.4 4.2 0.5 5.7 3 9 4 6 305 33.4 4.4 37.9 1.3 01/22/2006 14:50:00 4.7 0.6 5.7 3 4.4 0.6 5.3 3 13 4 13 305 30.8 10.4 36.6 -19 01/22/2006 15:00:00 3.7 0.8 6.1 2.3 3.4 0.8 5.7 1.9 6 11 1 305 33.2 1.6 36.6 27.6 01/22/2006 15:10:00 5.9 0.5 7.6 4.6 5.9 0.5 7.2 4.6 2 5 1 305 33.2 1.6 36.2 28.2 01/22/2006 15:20:00 6.5 0.6 7.6 4.6 6.3 0.6 7.6 4.6 16 6 8 305 33.7 1.9 37.2 29.5 01/22/2006 15:30:00 5.9 0.5 7.2 4.9 5.7 0.6 6.8 4.6 20 5 16 305 31.4 1.1 34.3 28.2 01/22/2006 15:40:00 5.5 0.3 6.5 4.6 5.4 0.4 6.1 4.6 24 3 18 305 33 1.3 35.3 28.2 01/22/2006 15:50:00 5.6 0.4 6.5 4.9 5.5 0.5 6.5 4.2 26 2 23 305 34 1 36.9 30.7 01/22/2006 16:00:00 4.4 0.2 4.9 3.8 4.1 0.2 4.9 3.4 28 2 28 305 36.2 2.1 38.9 17.9 01/22/2006 16:10:00 4.1 0.3 4.6 3.4 3.9 0.3 4.6 3.4 32 1 30 305 35.9 0.8 37.6 33.3 01/22/2006 16:20:00 3.2 0.5 4.2 2.3 3 0.5 4.2 1.9 46 8 35 305 35.4 0.8 36.9 32 01/22/2006 16:30:00 2.4 0.4 3.4 1.5 2.3 0.4 3.4 1.5 56 7 48 305 35.7 0.6 36.9 34.3 01/22/2006 16:40:00 2.5 0.3 3.4 1.5 2.4 0.3 3 1.5 49 7 58 305 35.7 0.9 37.9 33.3 01/22/2006 16:50:00 2.5 0.3 3 1.9 2.3 0.3 3.4 1.5 48 7 51 305 38.2 5.4 51.8 33.6 01/22/2006 17:00:00 2.6 0.3 3.4 1.9 2.5 0.3 3.4 1.9 47 5 40 305 47.1 5 51.8 13.2 01/22/2006 17:10:00 2.3 0.3 3.4 1.5 2.2 0.3 3 1.5 45 7 36 305 44.1 6.4 51.8 23.4 01/22/2006 17:20:00 2.3 0.3 3 1.5 2.2 0.3 3 1.5 36 6 41 305 41.6 8 49.9 22.5 01/22/2006 17:30:00 2.4 0.3 3.4 1.5 2.2 0.3 3 1.5 34 7 30 305 45.6 3.2 48.8 33.3 01/22/2006 17:40:00 1.7 0.4 2.6 0.7 1.5 0.3 2.3 0.7 30 11 19 305 44.4 1.2 47 40.6 01/22/2006 17:50:00 1.4 0.3 2.3 0.4 1.3 0.3 1.9 0.4 42 13 50 305 43.3 3.7 46.6 31.4 01/22/2006 18:00:00 1.1 0.4 1.9 0.4 1.1 0.3 1.9 0.4 34 11 43 305 42.6 4.5 47.7 32 01/22/2006 18:10:00 1.5 0.3 2.3 0.4 1.3 0.3 1.9 0.4 41 8 48 305 42.3 4.5 47.3 34.3 01/22/2006 18:20:00 1.7 0.3 2.3 0.7 1.6 0.2 2.3 1.1 41 7 51 305 44.7 3.1 48.1 33.3 01/22/2006 18:30:00 1.9 0.3 2.6 1.1 1.7 0.3 2.6 1.1 49 9 49 305 43.9 4.5 48.1 33.6 01/22/2006 18:40:00 1.7 0.2 2.3 1.1 1.5 0.2 2.3 0.7 50 6 45 305 45.5 2.7 47.7 34.9 01/22/2006 18:50:00 1.3 0.5 2.3 0.4 1 0.5 1.9 0.4 58 17 64 305 44.8 4 48.4 34.3 01/22/2006 19:00:00 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 101 22 56 305 43.6 5.4 48.8 32.3 01/22/2006 19:10:00 0.9 0.5 1.9 0.4 0.5 0.2 1.1 0.4 64 6 65 305 44.7 3.1 48.1 33.9 01/22/2006 19:20:00 1.5 0.5 2.6 0.4 1 0.5 2.3 0.4 61 13 67 305 42.9 5 48.4 33.3 01/22/2006 19:30:00 2 0.5 3 1.1 1.3 0.4 2.3 0.4 59 4 61 305 44.2 5 49.2 32 01/22/2006 19:40:00 2.9 0.4 3.8 1.9 2.2 0.4 3 1.1 64 3 67 305 43.7 3.1 47 32.6 01/22/2006 19:50:00 2.7 0.3 3.4 1.9 2.2 0.3 3 1.5 63 6 70 305 41.2 4.7 47 31.7 01/22/2006 20:00:00 3.1 0.2 3.8 2.6 2.8 0.3 3.4 1.9 52 4 50 305 37.9 5.2 45.9 24.6 01/22/2006 20:10:00 3 0.3 3.8 2.3 2.9 0.3 3.8 2.3 52 5 53 305 35.3 5.2 41 21.9 01/22/2006 20:20:00 2.7 0.3 3.4 2.3 2.5 0.3 3.8 1.9 48 5 49 305 34.4 5.2 42 22.8 01/22/2006 20:30:00 2.8 0.3 3.4 2.3 2.6 0.3 3.4 1.9 50 5 42 305 35.3 7.3 41.7 17.3 01/22/2006 20:40:00 3.3 0.3 4.2 2.6 3.1 0.3 3.8 2.3 62 4 62 305 37.8 1.1 40.3 32 01/22/2006 20:50:00 3.3 0.3 4.2 2.6 3 0.3 3.8 2.3 67 4 72 305 37.6 1.8 40.3 24.3 01/22/2006 21:00:00 2.8 0.3 3.8 1.9 2.5 0.3 3.4 1.9 65 5 65 305 35.3 4.5 39.6 21.9 01/22/2006 21:10:00 2.8 0.2 3.4 2.3 2.5 0.3 3 1.9 62 4 64 305 34.7 5.9 40.6 17.9 01/22/2006 21:20:00 3 0.2 3.4 2.3 2.7 0.3 3.4 2.3 62 3 59 305 37.2 3.5 40.6 24.9 01/22/2006 21:30:00 3.1 0.3 3.8 2.3 2.9 0.3 3.4 2.3 60 4 57 305 37.6 4.7 42.7 24.9 01/22/2006 21:40:00 3.1 0.3 3.8 2.6 2.8 0.3 3.4 1.9 61 5 70 305 33.4 7.3 40.6 19 01/22/2006 21:50:00 3.3 0.4 4.2 2.3 3.1 0.4 4.2 2.3 53 6 37 305 36 4.2 39.6 24.9 01/22/2006 22:00:00 3.2 0.3 4.2 2.3 2.9 0.3 3.8 2.3 57 7 56 305 35.6 3.4 40 23.7 01/22/2006 22:10:00 3.2 0.3 4.2 2.6 3 0.3 3.8 2.3 55 8 43 305 33.9 4.7 38.6 21.9 01/22/2006 22:20:00 2.9 0.3 3.8 2.3 2.7 0.3 3.4 1.9 46 7 33 305 31.9 6.2 39.3 21 01/22/2006 22:30:00 2.1 0.6 3 0.7 1.9 0.6 3 0.7 54 9 48 305 33.3 5.2 38.3 21.3 01/22/2006 22:40:00 0.9 0.2 1.5 0.4 0.8 0.2 1.1 0.4 55 11 66 305 32.1 6.2 38.6 12.9 01/22/2006 22:50:00 0.6 0.4 2.3 0.4 0.6 0.6 2.6 0.4 65 66 225 305 34.8 1.4 37.9 23.1 01/22/2006 23:00:00 0.9 0.4 1.9 0.4 1.5 0.4 2.3 0.4 227 8 224 305 33.1 0.8 34.9 29.8 01/22/2006 23:10:00 0.8 0.4 1.5 0.4 1.3 0.3 1.9 0.4 224 6 228 305 31 5.9 36.6 19 01/22/2006 23:20:00 0.8 0.3 1.5 0.4 1.4 0.4 2.3 0.7 198 5 214 305 31.4 4.4 35.3 19 01/22/2006 23:30:00 0.4 0 0.4 0.4 0.6 0.2 1.5 0.4 195 0 305 305 31 5.4 34.9 17.6 01/22/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 160 41 305 305 31.4 5 35.9 18.7 01/22/2006 23:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 113 0 305 305 29.2 6.2 35.9 17.3 01/23/2006 00:00:00 0.4 0.1 0.7 0.4 1.1 0.3 1.5 0.4 192 41 206 305 31.6 3.8 35.3 17 01/23/2006 00:10:00 0.8 0.4 1.9 0.4 1.2 0.3 1.9 0.7 212 13 208 305 32 0.7 33.6 29.8 01/23/2006 00:20:00 1.4 0.3 1.9 0.7 1.8 0.2 2.3 1.5 199 3 208 305 29.2 4.4 32 11.6 01/23/2006 00:30:00 1.3 0.3 1.9 0.7 1.7 0.3 2.3 1.1 191 3 194 305 29.3 4 33.6 16.2 01/23/2006 00:40:00 0.7 0.4 1.5 0.4 1 0.5 1.9 0.4 185 7 192 305 29.2 5.2 32.6 15.9 01/23/2006 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 170 11 305 305 25.4 5.9 31 13.4 01/23/2006 01:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 133 26 87 305 27.4 5 31.7 14.8 01/23/2006 01:10:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 79 2 87 305 27.6 2.1 29.8 13.2 01/23/2006 01:20:00 0.4 0.1 0.7 0.4 0.7 0.3 1.5 0.4 134 49 177 305 28.5 5 35.9 14 01/23/2006 01:30:00 0.8 0.5 2.3 0.4 1.4 0.6 2.6 0.4 205 16 221 305 27.5 5.2 31 3.4 01/23/2006 01:40:00 2.2 0.2 2.6 1.5 2.3 0.3 3 1.5 208 5 211 305 22.3 6.4 32.3 13.2 01/23/2006 01:50:00 2.2 0.2 2.6 1.5 2.3 0.4 3 1.5 217 3 220 305 17 0.8 19 11 01/23/2006 02:00:00 2.8 0.2 3.4 2.3 3.1 0.2 3.4 2.6 212 6 214 305 24.8 8 34.6 15.1 01/23/2006 02:10:00 2.8 0.3 3.4 1.9 2.9 0.3 3.4 1.9 208 5 205 305 29.8 4.5 33 13.4 01/23/2006 02:20:00 2.4 0.3 3 1.9 2.6 0.2 3.4 1.9 215 6 218 305 32.6 1.8 35.3 18.1 01/23/2006 02:30:00 2.6 0.3 3.8 1.9 2.8 0.3 3.4 1.9 211 7 200 305 33.3 1.3 35.3 25.5 01/23/2006 02:40:00 2.7 0.2 3 1.9 2.9 0.2 3.4 2.3 207 5 203 305 32.4 2.3 34.9 19 01/23/2006 02:50:00 2.6 0.3 3.4 1.9 2.8 0.3 3.8 1.9 214 7 210 305 30.6 5.4 35.3 17.3 01/23/2006 03:00:00 2.7 0.3 3.4 1.9 2.8 0.3 3.4 2.3 218 7 225 305 29.6 4.5 34.6 14.3 01/23/2006 03:10:00 3.1 0.3 3.8 2.6 3.3 0.3 4.2 2.6 208 7 214 305 22.9 5.9 31 15.3 01/23/2006 03:20:00 3.1 0.2 3.8 2.3 3.3 0.2 3.8 2.6 202 5 199 305 27.7 6.2 34.6 -6 01/23/2006 03:30:00 3.1 0.3 3.8 2.3 3.3 0.3 3.8 2.6 203 5 206 305 31.4 3.1 34.3 17.3 01/23/2006 03:40:00 3.4 0.3 4.2 2.6 3.6 0.2 4.2 3 209 5 210 305 29.2 5.9 34.9 16.7 01/23/2006 03:50:00 3.7 0.3 4.6 3 3.8 0.3 4.6 3 207 5 216 305 32.2 2.7 35.3 18.4 01/23/2006 04:00:00 4 0.3 4.6 3 4.1 0.3 4.9 3.4 201 5 208 305 33.1 3.5 39.3 19 01/23/2006 04:10:00 4.1 0.3 4.9 3.4 4.4 0.3 5.3 3.4 198 6 198 305 31.6 7.6 40.6 13.7 01/23/2006 04:20:00 4.3 0.3 5.3 3.8 4.6 0.3 5.7 3.8 199 5 203 305 31.5 8 40 13.4 01/23/2006 04:30:00 4.4 0.3 5.3 3.8 4.6 0.3 5.3 3.4 199 5 203 305 31 5 35.3 18.1 01/23/2006 04:40:00 4.5 0.4 5.7 3.4 4.8 0.3 5.7 3.4 196 6 197 305 31.2 6.7 37.9 16.7 01/23/2006 04:50:00 4.1 0.5 5.3 2.6 4.3 0.5 5.7 2.6 204 10 194 305 31.7 6.7 37.2 19.6 01/23/2006 05:00:00 3.3 0.5 4.6 1.9 3.4 0.4 4.9 2.3 209 10 204 305 32.7 5.6 37.2 17.9 01/23/2006 05:10:00 2.9 0.5 4.6 1.9 3.3 0.5 5.3 1.5 198 12 219 305 35.3 4.2 41.3 20.1 01/23/2006 05:20:00 2.3 0.5 3.8 0.7 2.3 0.5 3.8 0.4 212 15 203 305 36.2 3.5 42.7 19 01/23/2006 05:30:00 2 0.4 3 0.7 2.2 0.4 3.4 1.1 218 15 222 305 33.6 6.4 43.1 17.9 01/23/2006 05:40:00 1.8 0.6 3.8 0.4 2.1 0.4 3.4 1.1 200 15 210 305 38.9 5.2 44.8 20.1 01/23/2006 05:50:00 1.4 0.5 2.6 0.4 1.5 0.4 2.6 0.4 220 22 229 305 39.9 4.5 45.2 20.7 01/23/2006 06:00:00 1.5 0.4 2.6 0.7 1.6 0.4 2.6 0.4 229 13 243 305 40.5 4.2 46.6 19.6 01/23/2006 06:10:00 2.1 0.4 3 1.1 2.2 0.3 3 1.5 217 6 220 305 37.5 1.5 45.2 34.9 01/23/2006 06:20:00 2.9 0.4 3.8 1.9 2.9 0.3 3.8 1.9 220 8 235 305 36.8 0.6 38.9 34.6 01/23/2006 06:30:00 3.7 0.5 4.9 2.3 3.7 0.5 5.3 2.3 223 9 218 305 37.2 2.1 44.1 24.3 01/23/2006 06:40:00 3.8 0.4 4.9 2.3 3.8 0.4 4.9 2.6 225 10 236 305 37.8 5.9 45.5 20.4 01/23/2006 06:50:00 4 0.5 5.7 2.6 4 0.5 4.9 2.6 226 12 242 305 36.5 6.7 46.6 20.7 01/23/2006 07:00:00 4 0.6 5.7 2.6 3.8 0.5 5.3 1.9 235 12 238 305 38.3 6.2 45.9 20.7 01/23/2006 07:10:00 3.4 0.5 4.9 2.3 3.4 0.4 4.6 1.9 223 12 240 305 34.9 7 46.3 20.7 01/23/2006 07:20:00 4.3 0.5 5.7 2.6 3.5 0.4 4.9 2.6 243 12 251 305 28.5 4.2 34.3 20.1 01/23/2006 07:30:00 4.7 1.1 6.8 2.3 3.7 0.8 5.7 1.5 247 13 265 305 30.7 3.8 36.9 22.2 01/23/2006 07:40:00 5.9 0.7 7.2 4.6 4.2 0.6 6.1 2.3 262 4 259 305 31.8 2.9 35.3 21.9 01/23/2006 07:50:00 6.6 0.6 8 4.6 4.6 0.5 6.1 3 265 5 270 305 30.8 2.7 34.9 20.1 01/23/2006 08:00:00 6.4 0.5 7.6 4.6 4.6 0.5 6.5 3 262 5 264 305 30.6 3.1 35.3 20.4 01/23/2006 08:10:00 6.8 0.5 8.4 5.3 5.1 0.6 7.2 3.4 260 5 261 305 29.6 2.8 35.3 19.6 01/23/2006 08:20:00 6.2 0.6 7.6 4.6 4.6 0.6 6.8 3.4 261 5 259 305 29.5 3.2 35.6 21 01/23/2006 08:30:00 5.7 0.5 7.2 4.2 4.2 0.5 5.7 3 260 4 265 305 31.3 5.2 44.5 20.4 01/23/2006 08:40:00 5.4 0.4 6.5 4.2 4.1 0.5 5.3 2.6 259 4 254 305 38.8 4.5 44.5 20.1 01/23/2006 08:50:00 5.6 0.3 6.5 4.6 4.4 0.4 5.7 3 258 3 258 305 38.8 5 45.9 29.5 01/23/2006 09:00:00 5.1 0.4 6.1 3.4 4.2 0.4 5.3 2.6 255 5 264 305 38.8 4.5 45.5 28.5 01/23/2006 09:10:00 5.6 0.4 6.5 4.9 4.8 0.4 5.7 3.8 252 3 255 305 33.7 1.6 36.6 22.2 01/23/2006 09:20:00 5.7 0.3 6.5 4.6 4.8 0.4 6.1 3.8 252 3 255 305 30.5 5.4 40.6 22.5 01/23/2006 09:30:00 5.8 0.4 7.2 4.6 4.9 0.5 6.1 3.4 252 4 251 305 35.2 4 39.3 22.8 01/23/2006 09:40:00 5.5 0.5 6.5 4.2 4.6 0.5 6.1 2.6 253 5 249 305 34.3 5.2 39.3 21.6 01/23/2006 09:50:00 5.7 0.5 6.8 4.2 4.6 0.5 6.1 3.4 255 4 259 305 35.7 2.6 38.3 22.8 01/23/2006 10:00:00 5.3 0.5 6.1 4.2 4.5 0.5 5.7 3.4 253 3 261 305 29.3 5.4 38.9 17.9 01/23/2006 10:10:00 5 0.4 6.1 3.8 4.1 0.5 5.3 3 248 3 250 305 33.3 4.7 38.9 23.4 01/23/2006 10:20:00 5.3 0.3 6.1 4.6 4.4 0.4 5.3 3.4 252 3 251 305 34.4 2.8 37.6 21.9 01/23/2006 10:30:00 5.2 0.4 6.1 4.2 4.3 0.5 5.7 2.6 253 3 256 305 24.7 1 28.8 21.6 01/23/2006 10:40:00 5.2 0.3 6.1 4.2 4.4 0.4 5.3 3 250 2 250 305 25.8 1 27.9 23.1 01/23/2006 10:50:00 5.4 0.3 6.1 4.6 4.6 0.4 5.7 3.4 249 3 251 305 26.4 1.1 28.2 22.8 01/23/2006 11:00:00 5.9 0.4 6.8 4.6 5.1 0.5 6.5 3.4 251 3 251 305 37.5 5 41.3 24.9 01/23/2006 11:10:00 5.9 0.5 6.8 4.6 4.9 0.6 6.5 3 253 3 252 305 38.8 1 40.6 32 01/23/2006 11:20:00 5.8 0.4 6.5 4.9 5 0.4 6.1 3.8 251 3 251 305 32.4 5.6 39.3 24 01/23/2006 11:30:00 5.7 0.4 6.5 4.6 4.8 0.4 5.7 3.4 249 3 249 305 36.7 4.5 40.3 24.3 01/23/2006 11:40:00 5.5 0.3 6.5 4.6 4.6 0.5 5.7 3 251 3 252 305 36 5 41.7 25.2 01/23/2006 11:50:00 5.2 0.3 6.1 4.6 4.3 0.4 5.3 3 250 3 250 305 27.1 2.8 35.9 21.6 01/23/2006 12:00:00 5.2 0.3 6.1 4.6 4.4 0.4 5.3 3.4 251 3 252 305 27.6 0.5 28.8 25.8 01/23/2006 12:10:00 5.2 0.3 5.7 4.2 4.4 0.4 5.3 3.4 251 2 251 305 27.8 0.6 29.2 26.1 01/23/2006 12:20:00 4.9 0.3 5.7 3.8 4.1 0.4 4.9 3 250 2 258 305 28.1 1 30.1 25.5 01/23/2006 12:30:00 4.4 0.2 4.9 3.8 3.7 0.3 4.6 2.6 250 2 252 305 28.8 4.5 42 23.7 01/23/2006 12:40:00 4.5 0.3 4.9 3.8 3.9 0.3 4.6 3 247 3 251 305 39.1 2.2 41.7 27.6 01/23/2006 12:50:00 4.5 0.4 5.3 3.8 3.8 0.4 4.6 2.6 245 3 250 305 36.2 4.4 41 25.8 01/23/2006 13:00:00 3.8 0.4 4.6 3 3.4 0.3 4.2 2.6 236 6 236 305 36.2 5 40.3 24.9 01/23/2006 13:10:00 3.2 0.3 3.8 2.6 3.2 0.3 3.8 2.3 226 7 234 305 35.7 3.8 39.6 25.5 01/23/2006 13:20:00 3.4 0.4 4.6 2.3 3.3 0.4 4.2 2.3 227 9 224 305 34.8 4 40 25.8 01/23/2006 13:30:00 3.8 0.4 5.3 2.6 3.6 0.3 4.9 2.6 231 8 224 305 30.4 4 39.3 24.9 01/23/2006 13:40:00 3.3 0.4 4.6 2.3 3.2 0.4 4.2 1.9 225 9 221 305 26.5 0.9 28.5 23.1 01/23/2006 13:50:00 3.6 0.5 5.3 1.9 3.5 0.4 4.6 2.3 226 9 225 305 27.1 0.8 29.5 24.6 01/23/2006 14:00:00 4 0.7 6.1 2.6 3.8 0.6 5.3 2.3 231 11 242 305 29.5 3.5 37.6 25.5 01/23/2006 14:10:00 3.5 0.5 5.3 2.3 3.4 0.4 4.9 2.3 224 11 235 305 30.3 3.7 37.9 23.4 01/23/2006 14:20:00 3.3 0.4 4.6 2.3 3.3 0.3 4.2 2.6 223 9 232 305 29 3.2 37.6 24.9 01/23/2006 14:30:00 3.6 0.5 4.9 1.9 3.5 0.5 4.6 1.9 222 10 221 305 30.6 2.9 40.6 26.7 01/23/2006 14:40:00 3.6 0.7 5.7 1.9 3.4 0.6 5.3 1.9 232 13 236 305 30.2 0.8 32.3 27.9 01/23/2006 14:50:00 3.3 0.5 4.2 2.3 3 0.4 4.2 2.3 235 9 262 305 31.3 1.5 40.6 27.9 01/23/2006 15:00:00 3 0.5 4.6 1.9 2.7 0.4 3.8 1.5 232 10 234 305 32 1.8 41 28.5 01/23/2006 15:10:00 3.2 0.5 4.9 1.9 3 0.5 4.2 1.9 234 11 250 305 34.5 3.7 42 30.4 01/23/2006 15:20:00 3.4 0.4 4.6 2.3 3.4 0.4 4.6 1.9 218 10 225 305 34.1 3.4 42 30.4 01/23/2006 15:30:00 3.5 0.4 4.2 2.6 3.6 0.4 4.6 2.6 216 5 221 305 32.4 1.3 43.1 28.8 01/23/2006 15:40:00 3.7 0.3 4.6 3 3.9 0.3 4.6 3.4 213 5 217 305 40.5 3.7 44.5 32 01/23/2006 15:50:00 4 0.4 4.9 3 4 0.3 4.9 3 216 5 218 305 38.3 4.4 44.8 32 01/23/2006 16:00:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 213 5 213 305 35 0.7 36.6 33 01/23/2006 16:10:00 3.8 0.3 4.6 3 3.9 0.3 4.6 2.6 215 5 211 305 34.8 0.7 36.6 32.6 01/23/2006 16:20:00 3.8 0.3 4.6 3 3.9 0.3 4.6 3 210 5 219 305 35.3 0.6 36.6 33.3 01/23/2006 16:30:00 4 0.3 4.9 3 3.9 0.3 4.9 3 216 5 210 305 35.4 0.8 37.2 33.3 01/23/2006 16:40:00 3.8 0.4 4.9 3 3.9 0.3 4.6 2.6 213 6 211 305 40.1 3.7 48.4 34.3 01/23/2006 16:50:00 3.9 0.3 4.6 3 3.9 0.3 4.6 3 211 6 215 305 42.1 3.2 48.8 37.9 01/23/2006 17:00:00 3.9 0.4 4.9 3 4.1 0.3 4.9 3 208 7 218 305 47.4 5.2 52.9 38.3 01/23/2006 17:10:00 3.8 0.3 4.6 3 4 0.3 4.9 3.4 210 5 208 305 48.7 4.2 52.9 38.3 01/23/2006 17:20:00 3.8 0.3 4.6 2.6 3.9 0.3 4.6 3 208 6 202 305 50.2 3.8 52.9 37.9 01/23/2006 17:30:00 3.6 0.3 4.6 2.6 3.8 0.3 4.6 3 206 5 208 305 52 1 52.9 48.4 01/23/2006 17:40:00 3.9 0.3 4.6 3 4 0.3 4.9 3.4 208 6 204 305 45.8 5.4 52.9 35.9 01/23/2006 17:50:00 4.1 0.4 4.9 3 4.2 0.3 5.3 3.4 209 6 213 305 41.2 3.2 44.1 13.7 01/23/2006 18:00:00 4.4 0.4 5.3 3.4 4.5 0.4 5.3 3 212 5 211 305 36.5 7.3 44.5 5.2 01/23/2006 18:10:00 4.3 0.4 5.3 3.4 4.4 0.4 5.3 3.4 212 6 208 305 32.6 12.9 46.3 10.2 01/23/2006 18:20:00 4.2 0.3 5.3 3.4 4.4 0.3 5.3 3.8 208 5 214 305 40.8 8 49.5 4.9 01/23/2006 18:30:00 4.4 0.4 5.7 3.4 4.6 0.3 5.7 3.8 207 5 202 305 39.6 6.4 45.9 22.2 01/23/2006 18:40:00 4.5 0.4 5.7 3.4 4.6 0.4 5.7 3.4 207 6 208 305 39.8 7.3 45.5 11.3 01/23/2006 18:50:00 4.6 0.3 5.3 3.8 4.7 0.3 5.7 3.8 204 5 207 305 29.9 12.9 47.7 3.9 01/23/2006 19:00:00 4.7 0.3 5.3 3.8 4.9 0.3 5.7 3.8 203 4 203 305 33.8 19 50.6 -18.8 01/23/2006 19:10:00 4.6 0.3 5.3 3.8 4.9 0.3 5.3 4.2 201 4 194 305 43.9 7.6 51.8 9.5 01/23/2006 19:20:00 4.5 0.3 5.3 3.8 4.8 0.3 5.7 3.8 203 5 198 305 40.4 11.8 52.1 -18.4 01/23/2006 19:30:00 4.6 0.3 5.3 3.8 4.8 0.3 5.7 3.8 204 5 207 305 51.2 2.4 52.9 37.9 01/23/2006 19:40:00 4.3 0.4 5.3 3.4 4.5 0.4 5.3 3.4 208 6 208 305 50.8 2.5 52.9 47 01/23/2006 19:50:00 3.9 0.3 4.6 3 4.1 0.3 4.6 3.4 205 5 212 305 52.3 1.4 52.9 46.3 01/23/2006 20:00:00 3.9 0.3 4.6 3.4 4.1 0.3 4.6 3.4 203 5 205 305 48.8 6.2 52.9 13.7 01/23/2006 20:10:00 3.9 0.3 4.6 3 4 0.3 4.9 3.4 203 5 203 305 41.9 8.7 51.4 8.9 01/23/2006 20:20:00 3.9 0.2 4.6 3.4 4 0.2 4.6 3.4 205 4 199 305 48.9 3.8 52.9 37.6 01/23/2006 20:30:00 4 0.3 4.9 3.4 4.1 0.3 4.9 3.4 204 5 201 305 51.1 2.6 52.9 42 01/23/2006 20:40:00 4.1 0.3 4.9 3 4.3 0.3 4.9 3.4 202 4 208 305 51.2 2.4 52.9 39.3 01/23/2006 20:50:00 4.3 0.3 4.9 3.4 4.5 0.2 5.3 3.8 198 4 197 305 49.9 3.2 52.9 35.3 01/23/2006 21:00:00 4.5 0.3 5.3 3.8 4.7 0.3 5.3 3.8 197 4 208 305 47.9 3.1 52.9 24.3 01/23/2006 21:10:00 4.7 0.3 5.3 3.8 5 0.3 5.7 4.2 196 5 200 305 45.3 2.6 47.7 31.7 01/23/2006 21:20:00 4.7 0.3 6.1 3.8 4.9 0.3 6.1 4.2 196 3 192 305 43.2 3.2 47.3 29.8 01/23/2006 21:30:00 4.4 0.2 4.9 3.8 4.7 0.3 5.3 4.2 197 4 198 305 43.2 7 47 -18.4 01/23/2006 21:40:00 4.3 0.3 5.3 3.8 4.5 0.2 5.3 3.8 197 5 194 305 44.5 2.1 47.3 33.6 01/23/2006 21:50:00 4.1 0.3 4.9 3.4 4.4 0.2 4.9 3.8 196 3 197 305 44 2.3 46.6 32.3 01/23/2006 22:00:00 4.2 0.2 4.9 3.8 4.5 0.2 5.3 3.8 196 3 194 305 44.3 4.7 51 35.3 01/23/2006 22:10:00 4.1 0.2 4.6 3.4 4.4 0.2 4.9 3.8 195 4 195 305 48.2 3.7 52.1 34.6 01/23/2006 22:20:00 3.9 0.3 4.6 3 4.1 0.3 4.6 3.4 197 3 196 305 49.2 2 52.9 38.9 01/23/2006 22:30:00 4 0.2 4.6 3 4.2 0.2 4.6 3.4 203 3 196 305 47.3 3.7 52.5 30.7 01/23/2006 22:40:00 4.1 0.3 4.9 3.4 4.3 0.3 5.3 3.8 201 5 203 305 47.7 3.2 52.1 26.7 01/23/2006 22:50:00 4.6 0.3 5.3 3.8 4.8 0.3 5.7 4.2 201 4 201 305 43.6 2.3 47.7 30.1 01/23/2006 23:00:00 4.7 0.3 5.3 3.8 4.9 0.3 5.7 4.2 200 5 196 305 42.6 2.3 46.6 31.7 01/23/2006 23:10:00 4.5 0.3 5.3 3.8 4.7 0.3 5.3 3.8 200 4 208 305 42.8 2.6 46.3 32.6 01/23/2006 23:20:00 4.5 0.3 5.3 3.4 4.6 0.2 5.3 4.2 204 4 198 305 44 2.6 47 32.6 01/23/2006 23:30:00 4.1 0.3 4.9 3.4 4.2 0.3 4.9 3.4 201 5 208 305 43.6 2.7 46.3 31.7 01/23/2006 23:40:00 4.3 0.3 4.9 3.4 4.4 0.3 5.3 3.8 203 4 208 305 42.9 1.5 44.5 33.3 01/23/2006 23:50:00 4.3 0.3 4.9 3.4 4.4 0.3 4.9 3.4 203 5 205 305 42.9 2.9 46.6 33.6 01/24/2006 00:00:00 4.4 0.3 4.9 3.4 4.5 0.3 5.3 3.8 203 5 210 305 43.5 3.5 47.7 33.3 01/24/2006 00:10:00 4.1 0.3 4.9 2.6 4.3 0.3 4.9 3.4 201 6 194 305 43.9 3.7 47.7 34.9 01/24/2006 00:20:00 3.8 0.4 4.9 3 4 0.3 4.9 3.4 198 5 205 305 42.5 4 47.3 34.3 01/24/2006 00:30:00 3.6 0.3 4.6 3 3.9 0.3 4.6 3.4 196 5 194 305 41.5 2.7 44.8 34.3 01/24/2006 00:40:00 3.4 0.2 3.8 2.6 3.7 0.2 4.2 3 197 4 189 305 43.3 3.8 47.7 34.3 01/24/2006 00:50:00 3.2 0.2 3.8 2.6 3.5 0.2 4.2 2.6 196 4 193 305 45.3 5.2 50.6 34.3 01/24/2006 01:00:00 3.4 0.3 4.2 2.6 3.8 0.2 4.6 3.4 194 4 193 305 45.6 4.5 50.3 35.3 01/24/2006 01:10:00 3.7 0.2 4.2 3 4 0.2 4.6 3.4 196 3 198 305 45.9 3.4 49.9 34.3 01/24/2006 01:20:00 3.6 0.3 4.2 2.6 3.9 0.3 4.6 3 194 4 196 305 44.8 3.5 48.8 33.3 01/24/2006 01:30:00 3.6 0.3 4.6 3 4 0.3 4.6 3.4 196 3 193 305 44 3.1 48.4 32.6 01/24/2006 01:40:00 3.4 0.2 3.8 3 3.7 0.2 4.2 3 197 3 196 305 42 1.8 43.8 32 01/24/2006 01:50:00 3.3 0.2 3.8 2.6 3.6 0.2 4.2 3 196 3 195 305 42.3 1.8 44.5 32.6 01/24/2006 02:00:00 3.2 0.2 3.8 2.6 3.5 0.2 4.2 3 197 3 204 305 42.5 0.8 43.8 35.3 01/24/2006 02:10:00 3.4 0.2 4.2 3 3.8 0.2 4.2 3.4 198 3 196 305 39.7 5.6 45.5 30.7 01/24/2006 02:20:00 3.3 0.2 3.8 3 3.7 0.2 4.2 3.4 199 3 194 305 43.4 2.5 46.3 32 01/24/2006 02:30:00 3.7 0.2 4.2 3 4 0.3 4.6 3.4 195 3 193 305 39.4 6.2 45.5 30.4 01/24/2006 02:40:00 3.8 0.3 4.6 3.4 4.2 0.3 4.9 3.4 192 4 192 305 43.8 1.3 45.2 33 01/24/2006 02:50:00 3.7 0.2 4.2 3 3.8 0.2 4.6 3.4 191 2 191 305 43 0.8 44.5 35.3 01/24/2006 03:00:00 3.6 0.2 4.2 3 3.7 0.2 4.2 3 192 3 191 305 42.3 0.3 43.4 40.3 01/24/2006 03:10:00 3.8 0.2 4.2 3.4 4 0.2 4.6 3.4 189 3 189 305 42.2 0.8 43.8 33.3 01/24/2006 03:20:00 3.8 0.2 4.2 3 4 0.2 4.6 3.4 193 5 187 305 41.2 1.6 43.1 32 01/24/2006 03:30:00 3.7 0.2 4.2 3 3.9 0.2 4.6 3.4 197 4 198 305 41.1 1.2 42.4 32 01/24/2006 03:40:00 3.7 0.2 4.2 3 4 0.3 4.6 3 198 4 189 305 41.1 0.9 42.4 35.3 01/24/2006 03:50:00 3.6 0.2 4.2 2.6 3.7 0.2 4.2 3 201 4 201 305 41.1 0.5 42 39.3 01/24/2006 04:00:00 3.5 0.2 4.2 3 3.7 0.2 4.2 3.4 198 4 199 305 39.7 4 42.7 30.4 01/24/2006 04:10:00 3.7 0.2 4.2 3 3.8 0.2 4.6 3.4 200 4 198 305 31 0.9 32.6 27.6 01/24/2006 04:20:00 3.6 0.2 4.2 3 3.8 0.2 4.6 3.4 198 3 197 305 33 1.9 34.9 28.2 01/24/2006 04:30:00 3.7 0.2 4.6 3 3.9 0.2 4.6 3.4 194 3 193 305 36.8 2.9 42 33.3 01/24/2006 04:40:00 3.7 0.3 4.6 3 3.9 0.3 4.6 3 195 4 194 305 39 2.3 41.7 32.6 01/24/2006 04:50:00 3.4 0.2 3.8 3 3.5 0.2 4.2 3 197 4 197 305 40.4 2.5 45.2 32.3 01/24/2006 05:00:00 3.2 0.2 3.8 2.6 3.4 0.2 3.8 2.6 199 4 197 305 42 2.2 44.5 31.4 01/24/2006 05:10:00 2.9 0.2 3.8 2.3 3.1 0.2 3.8 2.3 199 4 202 305 42 1.9 43.8 30.7 01/24/2006 05:20:00 2.9 0.2 3.4 2.3 3.1 0.2 3.4 2.6 198 5 196 305 41.3 1.7 44.5 33 01/24/2006 05:30:00 2.8 0.3 3.4 1.9 3.1 0.2 3.8 2.6 193 5 197 305 41.4 0.7 42.7 35.6 01/24/2006 05:40:00 2.6 0.2 3 1.9 2.8 0.2 3.4 2.3 194 5 190 305 41.4 1.1 42.7 32 01/24/2006 05:50:00 2 0.2 2.6 1.5 2.2 0.2 2.6 1.9 195 5 192 305 40.2 1.1 42 29.8 01/24/2006 06:00:00 1.6 0.2 2.3 1.1 1.8 0.2 2.3 1.1 201 4 202 305 39.4 4.5 45.9 28.5 01/24/2006 06:10:00 1.5 0.2 1.9 1.1 1.6 0.2 1.9 1.1 194 3 198 305 41.5 1.8 43.8 31.4 01/24/2006 06:20:00 1 0.3 1.5 0.4 1.3 0.2 1.9 0.7 183 2 190 305 40.3 1.4 42 30.7 01/24/2006 06:30:00 0.6 0.2 1.1 0.4 1 0.2 1.5 0.4 177 4 182 305 40.6 2.8 43.1 28.5 01/24/2006 06:40:00 0.5 0.2 1.5 0.4 0.6 0.2 1.1 0.4 175 0 176 305 40.4 2.6 43.1 29.8 01/24/2006 06:50:00 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 190 21 221 305 39.9 4.2 43.8 30.4 01/24/2006 07:00:00 1.1 0.4 1.9 0.4 1.3 0.4 2.3 0.7 209 15 193 305 40.8 2.9 43.8 30.1 01/24/2006 07:10:00 1.7 0.2 2.3 1.1 1.9 0.2 2.3 1.5 183 3 188 305 41.6 2.8 48.8 31.4 01/24/2006 07:20:00 2 0.2 2.3 1.5 2.3 0.2 2.6 1.9 192 2 193 305 47.7 4.7 52.1 36.9 01/24/2006 07:30:00 1.9 0.2 2.3 1.1 2.1 0.3 2.6 1.5 188 3 188 305 46.6 2.9 52.1 32.6 01/24/2006 07:40:00 2.2 0.3 2.6 1.9 2.4 0.2 3 1.9 194 1 194 305 40.4 5 46.3 22.2 01/24/2006 07:50:00 2.4 0.2 3 1.9 2.5 0.2 3 2.3 193 1 194 305 42.6 3.7 46.6 31 01/24/2006 08:00:00 2.5 0.2 3 1.9 2.7 0.2 3 2.3 193 1 194 305 41.9 5.2 47.3 15.1 01/24/2006 08:10:00 2.5 0.3 3 1.9 2.5 0.3 3 1.5 189 4 194 305 34.7 3.7 38.3 19.3 01/24/2006 08:20:00 2.3 0.2 2.6 1.9 2.3 0.3 2.6 1.5 192 3 193 305 34.2 4 37.9 0.6 01/24/2006 08:30:00 2.4 0.2 2.6 1.9 2.5 0.2 2.6 1.9 193 1 194 305 33 3.1 36.6 19.6 01/24/2006 08:40:00 2.7 0.2 3 2.3 2.8 0.2 3.4 2.3 193 1 190 305 33.4 3.7 37.6 19 01/24/2006 08:50:00 2.5 0.2 2.6 2.3 2.6 0.2 3 2.3 191 2 194 305 39.3 5 44.5 20.1 01/24/2006 09:00:00 2.4 0.2 2.6 1.9 2.5 0.2 3 1.9 191 2 188 305 39.6 3.8 43.4 24.9 01/24/2006 09:10:00 2.5 0.2 2.6 2.3 2.6 0.2 3 2.3 192 1 194 305 39.7 2.1 42.7 26.4 01/24/2006 09:20:00 2.3 0.2 2.6 1.5 2.5 0.2 3 2.3 188 1 190 305 36.2 3.7 41.7 19 01/24/2006 09:30:00 2.3 0.2 2.6 1.9 2.5 0.2 3 1.9 193 2 190 305 34.2 3.8 40.3 19.3 01/24/2006 09:40:00 2.3 0.1 2.6 1.9 2.5 0.2 2.6 2.3 195 1 196 305 33 4.7 38.9 12.6 01/24/2006 09:50:00 2.4 0.2 2.6 1.9 2.6 0.2 3 2.3 197 1 193 305 32.9 5.4 38.6 11.8 01/24/2006 10:00:00 2.6 0.2 3 2.3 2.9 0.2 3.4 2.6 195 2 193 305 29.2 8.7 37.6 13.7 01/24/2006 10:10:00 2.9 0.2 3.4 2.6 3.2 0.2 3.4 2.6 196 1 196 305 30.3 3.5 33.9 15.1 01/24/2006 10:20:00 3.1 0.2 3.4 2.6 3.4 0.2 3.8 3 191 2 195 305 27.8 8.3 38.3 14.3 01/24/2006 10:30:00 3.4 0.2 4.2 3 3.6 0.2 4.2 3 190 2 189 305 34.9 3.5 37.9 23.4 01/24/2006 10:40:00 3.4 0.2 3.8 3 3.5 0.2 4.2 3 190 2 190 305 35.3 3.4 38.6 23.4 01/24/2006 10:50:00 3.4 0.2 4.2 3 3.6 0.3 4.2 3 189 3 188 305 33.2 3.4 37.2 16.5 01/24/2006 11:00:00 3.1 0.2 3.4 2.6 3.2 0.2 3.8 2.6 190 2 191 305 35.1 4.4 38.9 15.9 01/24/2006 11:10:00 2.9 0.2 3.4 2.3 3 0.2 3.8 2.6 189 2 189 305 35.2 3.4 38.6 19.9 01/24/2006 11:20:00 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.3 189 1 188 305 34.3 3.5 38.9 19 01/24/2006 11:30:00 2.6 0.2 3 2.3 2.6 0.2 3 2.3 193 2 189 305 33.7 4.7 41 18.7 01/24/2006 11:40:00 2.6 0.2 3 2.3 2.7 0.3 3.4 2.3 192 1 195 305 34.5 4 40.3 19 01/24/2006 11:50:00 2.5 0.2 3 2.3 2.6 0.2 3 2.3 196 2 198 305 31.6 2.9 39.3 20.7 01/24/2006 12:00:00 2.3 0.2 2.6 1.9 2.3 0.2 2.6 1.9 192 1 195 305 37.2 2.7 41.3 27 01/24/2006 12:10:00 2.6 0.2 3 2.3 2.7 0.3 3.4 2.3 192 0 192 305 33.5 5.2 39.6 18.7 01/24/2006 12:20:00 2.7 0.2 3 2.3 2.8 0.2 3.4 2.6 191 2 192 305 32.8 3.7 39.3 17.9 01/24/2006 12:30:00 2.7 0.2 3 2.3 2.7 0.2 3.4 2.3 190 2 189 305 33.2 4 38.3 17.3 01/24/2006 12:40:00 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.3 189 3 188 305 34.6 2.6 37.6 24 01/24/2006 12:50:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 191 2 192 305 32 3.8 37.6 20.1 01/24/2006 13:00:00 2.7 0.2 3 2.3 2.7 0.2 3.4 2.3 189 2 190 305 32.1 7 40.6 16.2 01/24/2006 13:10:00 2.4 0.2 2.6 1.9 2.2 0.2 2.6 1.5 192 3 189 305 36.7 1.8 39.3 27.3 01/24/2006 13:20:00 2.7 0.2 3 2.3 2.8 0.3 3.4 1.9 194 2 198 305 31.4 2.9 38.6 27.6 01/24/2006 13:30:00 2.7 0.2 3 2.3 3 0.2 3.4 2.6 191 0 191 305 35.4 3.5 40.3 24.9 01/24/2006 13:40:00 3 0.2 3.4 2.6 3.3 0.2 3.8 2.6 197 1 197 305 32.3 3.2 38.6 19.3 01/24/2006 13:50:00 3.4 0.2 3.8 3 3.7 0.2 4.2 3 197 2 195 305 30.6 2.8 34.3 17 01/24/2006 14:00:00 3.5 0.2 4.2 3 3.7 0.2 4.2 3.4 197 3 193 305 29.2 3.2 33.3 16.2 01/24/2006 14:10:00 3.3 0.2 3.8 2.6 3.5 0.2 4.2 3 195 3 190 305 15.2 1.9 18.7 11 01/24/2006 14:20:00 3.2 0.2 3.8 3 3.4 0.2 3.8 2.6 199 3 194 305 15.5 2.1 17.9 8.7 01/24/2006 14:30:00 3 0.2 3.8 2.6 3.2 0.3 3.8 2.3 200 4 201 305 11.4 1.7 14.3 8.2 01/24/2006 14:40:00 3.1 0.2 3.8 2.6 3.3 0.2 3.8 2.6 197 2 193 305 13.6 0.5 15.1 11.8 01/24/2006 14:50:00 2.8 0.2 3.4 2.3 3 0.2 3.4 2.3 197 4 200 305 13.9 0.5 15.3 12.4 01/24/2006 15:00:00 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.3 198 4 210 305 10.6 6.4 15.6 -16.6 01/24/2006 15:10:00 2.9 0.3 3.4 2.3 3 0.3 3.8 2.3 200 4 203 305 11.3 1.3 14 8.7 01/24/2006 15:20:00 2.6 0.2 3.4 1.9 2.7 0.2 3.4 1.9 204 5 203 305 13.2 0.5 15.1 11.6 01/24/2006 15:30:00 2.5 0.3 3.4 1.5 2.7 0.3 3.4 1.9 205 6 211 305 12.9 0.5 14 11.3 01/24/2006 15:40:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 208 5 213 305 13.8 0.8 15.9 11.6 01/24/2006 15:50:00 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.3 205 5 208 305 14.1 0.5 15.6 12.6 01/24/2006 16:00:00 2.8 0.2 3.8 2.3 2.9 0.3 3.4 2.3 203 6 201 305 18.2 5.4 27.3 10.2 01/24/2006 16:10:00 3 0.3 3.8 2.3 3 0.3 3.4 2.3 206 7 221 305 18.1 5.2 26.4 10.2 01/24/2006 16:20:00 3.4 0.3 4.2 2.6 3.4 0.3 4.6 2.6 205 6 208 305 19.8 0.9 22.5 17.9 01/24/2006 16:30:00 3.6 0.3 4.6 2.6 3.7 0.4 4.6 2.6 207 6 209 305 26.5 5.2 34.6 15.3 01/24/2006 16:40:00 3.7 0.3 4.9 3 3.8 0.3 4.6 3 207 5 210 305 30.8 3.4 34.3 20.1 01/24/2006 16:50:00 3.7 0.3 4.6 3 3.8 0.3 4.6 3 209 5 210 305 29.4 5.2 34.3 16.7 01/24/2006 17:00:00 3.9 0.3 4.6 3 3.9 0.3 4.6 3 209 6 206 305 29.2 4.7 33.6 18.7 01/24/2006 17:10:00 3.9 0.4 4.9 3 3.9 0.4 4.9 3 208 7 208 305 25.3 5.4 32.3 19.6 01/24/2006 17:20:00 3.9 0.4 4.9 3 3.9 0.3 4.9 3 208 6 207 305 29.2 3.7 32.6 19.3 01/24/2006 17:30:00 3.9 0.3 4.9 2.6 4.1 0.3 4.9 3 203 6 211 305 29 5 35.3 20.1 01/24/2006 17:40:00 4.3 0.3 4.9 3.4 4.4 0.3 4.9 3.8 204 4 198 305 28.3 6.2 35.6 18.7 01/24/2006 17:50:00 4.6 0.3 5.3 3.8 4.7 0.2 5.3 4.2 204 5 208 305 29.4 5.4 34.9 18.7 01/24/2006 18:00:00 4.3 0.3 4.9 3.4 4.5 0.3 5.3 3.4 200 5 205 305 31.5 4.7 37.2 17 01/24/2006 18:10:00 4.5 0.3 5.3 3.8 4.7 0.3 5.3 4.2 198 5 208 305 27.1 6.2 34.6 5.4 01/24/2006 18:20:00 4.5 0.3 5.3 3.8 4.6 0.3 5.3 3.8 198 5 203 305 25.7 5.2 32.6 16.5 01/24/2006 18:30:00 4.3 0.3 5.3 3.4 4.5 0.3 5.3 3.8 195 5 203 305 26.8 4.4 33 16.7 01/24/2006 18:40:00 4.1 0.3 4.9 3 4.4 0.3 5.3 3.4 194 5 199 305 30.3 1.5 34.6 21.9 01/24/2006 18:50:00 4.3 0.3 4.9 3.4 4.5 0.3 5.3 3.8 197 4 198 305 36.6 5.2 44.5 25.8 01/24/2006 19:00:00 4.3 0.3 4.6 3.4 4.4 0.2 4.9 3.8 197 4 193 305 36.1 5.9 43.4 23.4 01/24/2006 19:10:00 4.6 0.3 5.3 3.8 4.8 0.3 5.7 4.2 199 3 202 305 36.2 5.9 40.6 -17.5 01/24/2006 19:20:00 4.7 0.3 5.7 3.8 4.9 0.3 5.7 3.8 199 5 208 305 36.3 4.7 40.6 22.2 01/24/2006 19:30:00 4.8 0.3 5.3 3.8 4.9 0.3 6.1 4.2 198 5 195 305 31.2 7 41.7 -17.9 01/24/2006 19:40:00 4.8 0.3 6.1 3.8 5 0.4 5.7 4.2 201 5 200 305 39.4 1.7 41 31 01/24/2006 19:50:00 4.8 0.4 5.7 3.8 4.9 0.4 6.1 3.8 203 5 201 305 40.5 2.5 43.1 27.6 01/24/2006 20:00:00 4.5 0.3 5.7 3.4 4.6 0.3 5.3 3.8 204 6 208 305 40.9 1.3 43.1 34.6 01/24/2006 20:10:00 4.3 0.3 5.3 3.4 4.4 0.3 5.3 3.8 206 5 213 305 38 1.8 40 29.8 01/24/2006 20:20:00 4.1 0.3 4.9 3.4 4.3 0.3 4.9 3.4 205 5 213 305 31.4 5.6 38.3 15.3 01/24/2006 20:30:00 4.2 0.3 4.9 3.4 4.4 0.3 5.3 3.8 208 5 205 305 32.5 1.9 35.3 21.3 01/24/2006 20:40:00 4.2 0.3 4.9 3.4 4.4 0.3 5.3 3.4 204 6 198 305 34.3 3.5 37.6 19.3 01/24/2006 20:50:00 4.2 0.3 4.9 3.4 4.4 0.3 5.3 3.4 203 5 206 305 37.1 1.1 38.6 32 01/24/2006 21:00:00 4 0.3 4.9 3.4 4.2 0.3 4.9 3.4 206 5 203 305 36.2 1.2 37.9 24.9 01/24/2006 21:10:00 3.9 0.3 4.6 3 4 0.2 4.9 3.4 206 4 218 305 35.2 0.7 36.9 31.7 01/24/2006 21:20:00 3.6 0.3 4.2 2.6 3.8 0.3 4.6 3 205 6 210 305 35.2 0.7 36.6 32 01/24/2006 21:30:00 3.3 0.3 4.2 2.3 3.5 0.3 4.2 2.6 208 6 205 305 32.2 2 34.9 24 01/24/2006 21:40:00 3.3 0.2 3.8 2.6 3.5 0.3 4.2 2.6 204 6 206 305 32 5 36.6 21.9 01/24/2006 21:50:00 3.5 0.2 4.2 3 3.7 0.2 4.2 3 206 4 206 305 33 2.4 35.3 21.3 01/24/2006 22:00:00 3.5 0.2 3.8 3 3.8 0.2 4.2 3.4 206 4 203 305 23.4 4.5 34.6 19 01/24/2006 22:10:00 3.7 0.2 4.2 3 3.9 0.2 4.6 3.4 204 4 200 305 15.4 4.7 29.2 8.7 01/24/2006 22:20:00 3.6 0.2 4.2 3 3.9 0.2 4.6 3.4 203 4 201 305 16.7 7.3 31 8.7 01/24/2006 22:30:00 3.7 0.3 4.2 3 4.1 0.2 4.6 3.4 202 5 198 305 26.8 4.2 29.8 15.3 01/24/2006 22:40:00 3.8 0.3 4.6 3 4.1 0.2 4.6 3.8 200 5 208 305 17.5 3.7 28.8 14.3 01/24/2006 22:50:00 3.7 0.3 4.6 3 4.1 0.3 4.6 3.4 202 4 203 305 34 9.5 45.2 13.7 01/24/2006 23:00:00 3.4 0.3 4.2 2.6 3.7 0.3 4.6 3 202 6 193 305 43 1.4 45.5 35.3 01/24/2006 23:10:00 3.2 0.2 3.8 2.6 3.5 0.2 4.2 3 203 5 207 305 42 0.8 44.1 39.3 01/24/2006 23:20:00 3.3 0.3 4.2 2.6 3.6 0.2 4.2 3 203 4 205 305 42.7 2.6 46.6 22.8 01/24/2006 23:30:00 3.3 0.3 4.2 2.6 3.7 0.2 4.6 3 204 5 208 305 44.6 1 46.6 40.6 01/24/2006 23:40:00 3.5 0.4 4.2 2.6 3.8 0.4 4.6 2.6 205 9 227 305 45 1 46.6 33.3 01/24/2006 23:50:00 4.1 0.3 5.3 3.4 4.5 0.3 5.3 3.4 203 5 200 305 51.8 1.9 52.9 42 01/25/2006 00:00:00 4.1 0.3 4.9 3.4 4.5 0.4 5.3 3.4 202 6 204 305 47.9 5.6 52.9 36.9 01/25/2006 00:10:00 3.9 0.4 4.9 3 4.3 0.3 4.9 3.4 201 6 197 305 39.8 1.4 42.4 27 01/25/2006 00:20:00 4 0.4 4.9 2.3 4.3 0.4 5.3 2.6 202 8 192 305 39.4 1.4 42 27.9 01/25/2006 00:30:00 3.6 0.4 4.2 2.6 3.9 0.4 4.9 3 201 5 205 305 33 6.7 43.1 25.5 01/25/2006 00:40:00 3.5 0.3 4.6 2.6 3.8 0.3 4.6 3 200 6 196 305 42.9 5.9 52.9 27.6 01/25/2006 00:50:00 3.5 0.3 4.2 2.6 3.8 0.2 4.6 3.4 200 5 211 305 52.2 1.6 52.9 40 01/25/2006 01:00:00 3.9 0.3 4.6 3 4.1 0.3 4.9 3.4 197 5 202 305 52.4 1.1 52.9 46.3 01/25/2006 01:10:00 3.8 0.3 4.6 3 4.1 0.3 4.9 3.4 197 5 192 305 50.3 3.4 52.9 33.6 01/25/2006 01:20:00 4.1 0.4 5.3 3 4.3 0.4 5.7 3.4 199 6 198 305 43.2 7 52.9 26.7 01/25/2006 01:30:00 4.3 0.5 5.3 2.6 4.7 0.4 5.7 3.8 196 6 204 305 40.7 7.3 51 28.5 01/25/2006 01:40:00 4.2 0.3 4.9 3.4 4.6 0.3 5.3 3.8 196 6 199 305 50.8 3.7 52.9 31 01/25/2006 01:50:00 3.6 0.3 4.2 2.6 3.8 0.3 4.6 3 195 5 203 305 38.6 3.2 52.9 24.6 01/25/2006 02:00:00 3.1 0.2 3.8 2.6 3.3 0.3 3.8 2.6 204 6 208 305 41.5 5.6 51 28.2 01/25/2006 02:10:00 3.3 0.3 4.2 2.6 3.5 0.3 4.2 2.6 205 5 205 305 40 7 49.5 20.7 01/25/2006 02:20:00 2.9 0.3 3.8 1.9 3.2 0.3 3.8 2.6 198 7 192 305 30 6.4 37.9 6.1 01/25/2006 02:30:00 2.7 0.3 3.4 1.5 3.1 0.3 3.8 2.3 199 10 187 305 34.6 6.2 44.5 9.7 01/25/2006 02:40:00 2.3 0.4 3 1.1 2.6 0.4 3.4 1.5 210 7 221 305 40.5 3.8 45.5 21 01/25/2006 02:50:00 1.9 0.3 2.6 1.1 2.3 0.3 3 1.9 208 7 210 305 41.5 3.4 44.8 11.8 01/25/2006 03:00:00 0.9 0.5 2.3 0.4 1.3 0.7 2.6 0.4 212 10 208 305 35.8 8.3 47.7 13.4 01/25/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 231 13 305 305 27 3.7 41.3 17.3 01/25/2006 03:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 346 53 42 305 37.2 5.4 42.7 21.6 01/25/2006 03:30:00 0.5 0.4 1.9 0.4 0.4 0.2 1.5 0.4 355 14 24 305 36 7 44.5 23.7 01/25/2006 03:40:00 2.5 0.8 4.6 0.4 2.3 0.8 3.4 0.4 36 9 35 305 41.3 3.1 45.2 34.9 01/25/2006 03:50:00 3.8 0.5 5.3 2.6 3.7 0.5 5.3 2.3 37 5 44 305 36.9 3.5 44.1 26.4 01/25/2006 04:00:00 4 0.6 5.7 2.6 3.9 0.6 6.1 2.6 30 12 12 305 40.5 6.4 46.6 13.7 01/25/2006 04:10:00 4.9 0.6 6.1 3 4.9 0.6 6.1 3.4 9 4 12 305 36.2 4.7 45.5 14.5 01/25/2006 04:20:00 4.8 0.5 6.1 3.4 4.8 0.5 6.1 3.4 5 3 6 305 34.3 1.5 36.9 27.6 01/25/2006 04:30:00 5.4 0.4 6.5 4.2 5.3 0.4 6.5 4.2 8 3 11 305 37.4 1.6 40 21.9 01/25/2006 04:40:00 5 0.3 6.1 3.8 5 0.3 5.7 4.2 10 5 13 305 36.8 3.8 39.6 17.6 01/25/2006 04:50:00 5.7 0.5 6.5 4.2 5.7 0.5 6.8 4.2 12 4 14 305 35.7 7.6 44.1 18.7 01/25/2006 05:00:00 5.1 0.4 6.1 4.2 5.1 0.5 6.1 4.2 6 5 4 305 35.3 2.6 42 26.1 01/25/2006 05:10:00 5.7 0.6 7.2 4.2 5.7 0.6 6.8 4.6 17 4 21 305 28.5 11.3 46.3 14.8 01/25/2006 05:20:00 7 0.5 8 5.7 6.9 0.6 8.4 4.9 18 4 15 305 27.5 9.9 48.8 11 01/25/2006 05:30:00 7.1 0.7 8.4 4.9 7 0.8 8.8 5.3 20 4 22 305 32.9 7.6 46.6 11.8 01/25/2006 05:40:00 7.4 0.5 8.4 6.1 7.4 0.5 8.4 5.7 19 3 21 305 27.4 10.8 41 10.5 01/25/2006 05:50:00 6.2 0.5 7.2 4.6 6.1 0.5 7.2 4.9 19 5 21 305 30.3 10.8 48.4 10.8 01/25/2006 06:00:00 6.7 0.6 8 4.6 6.7 0.6 8.4 4.9 19 4 22 305 34.1 12.3 45.2 -15.4 01/25/2006 06:10:00 7.7 0.6 9.1 6.1 7.6 0.7 9.1 6.1 21 5 18 305 32.6 9.1 43.4 -15 01/25/2006 06:20:00 7.5 0.7 8.8 5.3 7.5 0.7 8.8 5.7 24 5 21 305 37.7 10.4 51.8 -1.1 01/25/2006 06:30:00 7.8 0.6 9.5 5.7 7.8 0.6 9.1 5.7 30 7 37 305 36.8 12.3 51 -15.4 01/25/2006 06:40:00 8 0.8 9.9 6.1 7.9 1 10.3 5.7 33 6 36 305 11 14.6 36.6 -15.8 01/25/2006 06:50:00 8.1 0.7 9.5 6.1 8 0.7 9.5 6.1 32 5 35 305 33.5 2.8 41 25.5 01/25/2006 07:00:00 8.8 0.7 10.3 6.8 8.7 0.8 10.3 6.5 35 6 42 305 25.1 9.9 38.9 8.2 01/25/2006 07:10:00 8.3 0.9 10.3 6.1 8.3 0.8 9.9 5.7 37 6 42 305 26.1 8.7 36.9 10.8 01/25/2006 07:20:00 8.3 1 10.3 6.1 8.2 1 10.7 5.3 41 8 49 305 37.2 1.9 41.3 32 01/25/2006 07:30:00 7.5 0.7 9.5 5.7 7.5 0.8 9.5 5.3 54 4 50 305 25.6 13.4 40.6 -16.4 01/25/2006 07:40:00 7.2 0.8 9.5 4.9 7.1 0.8 9.5 5.3 47 7 50 305 26.4 8.3 37.6 -11.5 01/25/2006 07:50:00 8.2 1.1 10.7 6.1 8.1 1.2 11.1 5.3 43 6 40 305 32.5 3.7 36.2 11.3 01/25/2006 08:00:00 8.6 0.8 10.3 6.5 8.5 0.9 10.7 6.5 45 6 51 305 31.8 3.4 38.3 11.3 01/25/2006 08:10:00 8.2 0.9 10.3 6.1 8.1 0.9 10.3 6.1 48 5 48 305 29.9 4.5 34.9 10.5 01/25/2006 08:20:00 8.9 0.7 10.7 6.8 8.9 0.8 10.3 6.8 42 6 44 305 31 8.3 36.6 -16.4 01/25/2006 08:30:00 8.9 1 11.1 6.5 8.9 1 11.5 6.5 38 7 31 305 30.8 10.8 37.9 -16.6 01/25/2006 08:40:00 8.1 0.8 9.9 5.7 8 0.7 9.9 5.7 40 7 35 305 34.5 3.8 41.7 21.9 01/25/2006 08:50:00 9.6 1.1 11.8 6.1 9.5 1.2 11.8 5.7 39 6 39 305 36.2 4.5 42 10.5 01/25/2006 09:00:00 10.2 1 12.6 7.6 10.1 1 12.6 7.6 38 5 41 305 33.5 5.6 40.3 -7.1 01/25/2006 09:10:00 9.9 1 11.8 7.2 9.8 1.1 12.2 7.2 41 7 33 305 34.6 8 44.1 -3.1 01/25/2006 09:20:00 9.6 1.2 11.8 6.8 9.6 1.2 12.2 7.2 39 6 40 305 31.6 4.4 37.9 8.9 01/25/2006 09:30:00 10.4 1 12.6 7.2 10.4 1 12.6 7.2 40 5 37 305 36.7 3.4 42.4 15.3 01/25/2006 09:40:00 9.7 0.8 11.5 7.2 9.6 0.8 11.5 7.6 42 5 36 305 26.2 11.8 43.4 -12.5 01/25/2006 09:50:00 8.2 0.9 10.3 6.1 8.2 1 10.7 5.7 45 6 40 305 44.6 8.3 52.9 17.6 01/25/2006 10:00:00 8.6 0.6 10.3 6.8 8.6 0.7 10.7 7.2 49 6 51 305 51.1 4.4 52.9 20.1 01/25/2006 10:10:00 8 0.8 9.9 5.7 7.8 0.8 9.9 6.1 54 5 53 305 51.1 3.5 52.9 24.9 01/25/2006 10:20:00 7.2 0.5 8.8 5.7 7.1 0.5 8.8 5.7 59 4 60 305 48.5 5.2 52.9 28.8 01/25/2006 10:30:00 7.3 0.8 9.9 5.3 7.1 0.8 9.5 5.3 54 6 51 305 45.1 7 52.9 12.9 01/25/2006 10:40:00 6.5 0.4 7.6 5.3 6.4 0.5 7.6 4.9 53 5 50 305 49.6 2.6 52.9 30.7 01/25/2006 10:50:00 6.8 0.5 8 5.3 6.7 0.6 8 5.3 56 3 57 305 49.5 2.2 52.9 35.9 01/25/2006 11:00:00 7 0.6 8.4 5.3 6.9 0.6 8.4 4.9 49 5 46 305 49.4 2.5 52.9 33.3 01/25/2006 11:10:00 7.6 0.6 9.1 6.1 7.5 0.6 9.1 5.7 49 5 47 305 49.4 2.8 52.9 31 01/25/2006 11:20:00 8 1 10.7 5.7 7.9 1.1 10.3 5.7 48 7 39 305 49.1 5.4 52.9 33.3 01/25/2006 11:30:00 7.3 0.5 8.8 6.1 7.2 0.5 8.8 5.7 51 5 45 305 51.6 2.5 52.9 36.2 01/25/2006 11:40:00 6.8 0.5 8.8 5.3 6.7 0.5 8.4 5.3 57 5 54 305 52.5 0.5 52.9 47.3 01/25/2006 11:50:00 6.8 0.5 8 5.3 6.7 0.6 8 5.7 55 4 53 305 51.8 2.6 52.9 39.3 01/25/2006 12:00:00 6.7 0.4 8 5.7 6.6 0.5 7.6 5.3 52 4 46 305 51.9 2.5 52.9 38.6 01/25/2006 12:10:00 7 0.5 8.4 5.7 6.8 0.6 8.8 5.3 53 5 53 305 52.6 0.8 52.9 41.3 01/25/2006 12:20:00 6.6 0.6 8 5.3 6.4 0.6 8 4.9 57 4 56 305 47.8 6.2 52.9 34.9 01/25/2006 12:30:00 7.2 0.6 8.4 5.3 7.3 0.7 8.8 5.3 57 3 59 305 46.2 6.7 52.9 17.6 01/25/2006 12:40:00 7.3 0.5 8.4 6.1 7.3 0.5 8.8 5.7 58 4 59 305 41 3.2 43.8 17 01/25/2006 12:50:00 7.4 0.5 8.4 6.1 7.1 0.5 8.4 5.3 63 3 60 305 41.6 1 43.8 37.9 01/25/2006 13:00:00 7.6 0.4 8.4 6.5 7.3 0.5 8.4 5.7 63 4 62 305 41.5 1.2 43.8 30.4 01/25/2006 13:10:00 6.6 0.5 8 5.3 6.4 0.5 7.6 4.9 64 5 65 305 40.6 1.3 42.4 35.3 01/25/2006 13:20:00 6.8 0.5 7.6 5.7 6.5 0.5 7.6 5.3 64 4 62 305 41.3 1.8 44.1 26.1 01/25/2006 13:30:00 6.6 0.5 7.6 4.9 6.3 0.6 7.6 4.6 65 4 65 305 41.1 2 43.1 19.9 01/25/2006 13:40:00 6.7 0.5 7.6 4.9 6.4 0.5 7.6 4.9 63 4 62 305 40.5 0.7 42.4 35.9 01/25/2006 13:50:00 7 0.5 8 5.7 6.6 0.5 8 5.3 63 4 63 305 40.1 1.1 41.7 28.5 01/25/2006 14:00:00 5.7 0.6 8 4.6 5.4 0.6 7.2 3.8 62 5 62 305 41.9 2.2 46.6 23.4 01/25/2006 14:10:00 5.1 0.5 6.5 4.2 4.9 0.5 6.1 3.8 60 5 62 305 41.5 2.4 47.3 33.6 01/25/2006 14:20:00 5.4 0.4 6.5 4.2 5.2 0.5 6.5 4.2 58 4 61 305 38.5 7.3 47 21.9 01/25/2006 14:30:00 4.4 0.5 5.7 3 4.4 0.5 6.1 3 57 4 54 305 37.2 7 44.8 21.9 01/25/2006 14:40:00 3.6 0.4 4.6 2.6 3.4 0.4 4.6 2.3 59 7 54 305 36.8 6.4 45.9 20.1 01/25/2006 14:50:00 3.2 0.4 4.2 2.3 3.1 0.4 4.6 2.3 57 9 45 305 41.6 3.7 44.5 21.3 01/25/2006 15:00:00 3.2 0.5 4.6 2.3 2.9 0.5 4.2 1.5 63 9 74 305 39.3 5 43.8 17 01/25/2006 15:10:00 3.4 0.5 4.6 2.3 3.3 0.5 4.6 1.9 57 7 53 305 33 8 43.1 18.7 01/25/2006 15:20:00 3.4 0.4 4.6 2.6 3.2 0.4 4.2 2.3 62 6 64 305 21.8 0.5 23.1 19 01/25/2006 15:30:00 3.2 0.4 4.6 2.3 3.1 0.4 4.2 2.3 55 7 61 305 22.5 8.3 47.3 -3.8 01/25/2006 15:40:00 3.4 0.4 4.6 2.3 3.4 0.4 4.2 2.3 52 6 54 305 39.8 5 51.4 24.9 01/25/2006 15:50:00 3.2 0.3 3.8 2.6 3.2 0.3 4.2 2.3 53 6 57 305 41 2.8 45.5 20.4 01/25/2006 16:00:00 3.3 0.3 4.2 2.6 3.2 0.3 4.2 2.6 51 6 54 305 40.6 2.4 43.8 19.3 01/25/2006 16:10:00 3 0.4 4.2 1.9 3 0.5 4.2 1.9 49 9 46 305 40.6 3.1 45.5 16.2 01/25/2006 16:20:00 3.1 0.3 4.2 2.3 3 0.3 3.8 2.3 34 6 35 305 36.7 4.7 43.8 14.3 01/25/2006 16:30:00 2.8 0.3 3.8 2.3 2.9 0.2 3.4 2.3 33 5 30 305 35 4.7 38.6 11 01/25/2006 16:40:00 2.7 0.3 3.8 1.9 2.6 0.3 3 1.9 31 7 18 305 38.4 3.8 44.5 10.2 01/25/2006 16:50:00 2.3 0.6 3.4 0.4 2.3 0.5 3.4 0.7 30 10 35 305 32.6 4.4 39.3 6.4 01/25/2006 17:00:00 2.1 0.7 3.8 0.7 1.8 0.6 3.8 0.4 29 17 358 305 35.9 3.8 42.7 11.3 01/25/2006 17:10:00 5.4 1.3 7.6 3 5.3 1.4 7.6 2.6 10 9 359 305 35 1.7 37.9 14 01/25/2006 17:20:00 8.6 1.1 11.1 6.5 8.6 1.1 11.1 6.1 10 6 15 305 35.1 6.4 42.4 11.3 01/25/2006 17:30:00 10.7 1.1 12.6 7.2 10.5 1.1 12.6 7.2 17 4 18 305 45.5 7.3 52.9 13.2 01/25/2006 17:40:00 10.3 1.2 12.6 7.2 10.2 1.1 12.6 7.2 16 5 18 305 44.4 6.7 52.9 28.8 01/25/2006 17:50:00 11.2 1 13.3 8.4 11 1 13.7 8.4 13 5 13 305 37.3 3.7 50.6 11.8 01/25/2006 18:00:00 11.7 1.3 14.9 9.1 11.5 1.3 14.9 8.8 13 5 16 305 45 5.9 52.5 35.3 01/25/2006 18:10:00 12.1 1 14.5 9.1 12 1 14.1 9.1 17 5 18 305 43.9 7 52.9 34.3 01/25/2006 18:20:00 11.4 0.9 13.7 8.8 11.2 1 13.7 8.4 24 5 19 305 41.4 7.6 52.9 9.2 01/25/2006 18:30:00 11.3 1 13.7 8.4 10.9 1.1 13.7 8 23 7 10 305 39.7 6.7 52.5 34.3 01/25/2006 18:40:00 11.7 1 14.1 8.4 11.6 1.1 14.1 8.8 24 5 19 305 34.8 0.4 35.9 33.3 01/25/2006 18:50:00 10.4 1 12.6 7.6 10.2 1 12.2 8 28 5 33 305 33.2 1.3 35.3 29.5 01/25/2006 19:00:00 10.7 1.1 12.6 7.2 10.5 1.2 12.6 6.8 26 6 21 305 33.4 6.4 37.6 10.8 01/25/2006 19:10:00 9.2 0.9 11.8 6.8 9.1 1 11.8 6.5 24 6 21 305 31.6 6.7 36.9 9.2 01/25/2006 19:20:00 8.9 1 11.8 5.7 8.8 1 11.8 6.1 24 6 21 305 35.6 9.9 52.9 10 01/25/2006 19:30:00 9.3 0.8 11.1 6.8 9.2 0.9 11.1 6.8 21 6 32 305 41.2 8 52.9 12.4 01/25/2006 19:40:00 9.9 1 11.8 7.2 9.7 1 12.2 7.2 18 5 14 305 45.3 8.3 52.9 11.8 01/25/2006 19:50:00 10.3 1 13 7.6 10.1 1.1 12.6 6.8 23 7 34 305 33.4 14.6 52.9 11.8 01/25/2006 20:00:00 11.1 1.1 14.1 8 10.9 1.1 13.7 7.6 15 5 16 305 41.6 12.9 52.9 11.3 01/25/2006 20:10:00 10.8 1.1 13.3 7.6 10.6 1.2 14.1 7.2 17 5 19 305 47.4 5.9 52.9 36.2 01/25/2006 20:20:00 10.2 0.9 12.6 7.2 10.1 1 12.6 7.2 15 6 24 305 36.1 0.8 37.6 29.8 01/25/2006 20:30:00 10.1 1 11.8 7.6 9.9 1 12.6 6.8 19 6 25 305 33.3 3.2 35.6 6.9 01/25/2006 20:40:00 9.6 0.9 11.8 7.6 9.6 0.9 11.8 7.2 19 6 22 305 31.9 2.3 34.3 6.9 01/25/2006 20:50:00 10.2 1 12.6 7.2 10.2 1 13 7.6 20 8 25 305 32.1 2.3 33.6 4.9 01/25/2006 21:00:00 10.3 0.7 11.8 8 10.2 0.9 12.6 8 19 7 14 305 31.5 2.8 33.6 5.9 01/25/2006 21:10:00 11.4 1 14.1 9.1 11.2 1 14.1 8.8 17 5 18 305 25.8 12.3 46.6 4.4 01/25/2006 21:20:00 9.5 1 11.5 6.5 9.5 1.1 12.2 6.8 23 6 20 305 39.4 8 48.8 6.9 01/25/2006 21:30:00 10.7 1.3 14.5 7.2 10.5 1.2 13.7 7.2 14 5 25 305 38.4 9.9 49.2 7.2 01/25/2006 21:40:00 11.5 1.2 14.1 8.4 11.3 1.2 14.5 8.4 18 5 21 305 25.3 12.9 47 -2.2 01/25/2006 21:50:00 11.5 1 14.1 8.8 11.1 1 13.3 8 23 6 21 305 28.6 10.4 37.2 4.9 01/25/2006 22:00:00 11.3 0.9 13.3 8.8 11.2 1 14.1 9.1 23 6 24 305 33.1 5.9 38.3 4.2 01/25/2006 22:10:00 10.7 1.5 14.5 6.5 10.6 1.5 14.5 6.1 16 7 21 305 32.1 2 34.6 5.2 01/25/2006 22:20:00 11.4 1.2 14.1 8 10.9 1.2 13.3 6.5 14 9 9 305 32.2 5 39.6 3.7 01/25/2006 22:30:00 12.3 1.2 15.3 8.8 12 1.3 16.1 8.8 13 6 9 305 36.7 1.4 40.6 31.4 01/25/2006 22:40:00 11.4 1.2 14.9 8.8 11.3 1.3 15.3 8 13 6 6 305 33.8 4.2 37.6 0.6 01/25/2006 22:50:00 11.9 1.3 15.3 9.1 11.6 1.2 14.9 8.8 15 7 21 305 27.2 14.6 42.7 -24.4 01/25/2006 23:00:00 12.8 1.3 16.4 9.1 12.4 1.4 16.1 9.1 18 6 23 305 36.7 5.6 43.1 3.2 01/25/2006 23:10:00 12 1.2 14.5 9.1 11.6 1.3 14.9 8 13 6 13 305 31.8 12.3 44.1 -24.6 01/25/2006 23:20:00 13.2 1.2 15.6 9.9 12.8 1.2 15.3 9.5 15 5 13 305 31.8 12.9 44.1 1 01/25/2006 23:30:00 12.3 1 14.5 9.1 12 1.1 14.5 9.5 18 6 16 305 31 9.1 41.3 -24.4 01/25/2006 23:40:00 11.7 1 13.7 8.4 11.5 1.1 14.1 8.4 15 5 14 305 26 0.8 27.6 19.6 01/25/2006 23:50:00 12.2 1 14.5 9.5 12 1.3 15.3 9.1 14 5 15 305 24.9 1.5 26.7 10 01/26/2006 00:00:00 11 1.3 14.1 7.2 10.9 1.4 14.1 6.8 18 7 31 305 23.4 3.4 25.5 -24.6 01/26/2006 00:10:00 11.9 1.1 14.5 8.4 11.6 1 14.5 8.8 15 5 13 305 23.6 2.2 25.5 6.4 01/26/2006 00:20:00 11.1 1.1 13.7 8.8 11 1.2 14.1 8.4 13 5 14 305 22.1 2.5 24.9 4.4 01/26/2006 00:30:00 10.3 1.1 13.3 7.6 10 1.2 13.3 7.2 13 7 12 305 21.4 2.6 23.7 3.9 01/26/2006 00:40:00 11.2 0.9 13.7 8.4 11 1 14.5 8.8 9 4 18 305 13.2 7.3 21.6 0.3 01/26/2006 00:50:00 10.1 0.8 12.6 8 10.2 1 13 7.6 7 6 4 305 26.3 7.6 34.3 -0.8 01/26/2006 01:00:00 8.9 1.1 11.1 6.1 8.9 1.1 11.1 6.1 8 13 1 305 15.6 14 33.9 -12.1 01/26/2006 01:10:00 7.7 1 9.5 5.3 7.6 1 9.9 4.9 21 7 17 305 25 12.3 38.6 -8.6 01/26/2006 01:20:00 8.5 0.8 9.9 6.5 8.5 0.9 10.3 6.1 16 5 22 305 32.6 3.7 42 21 01/26/2006 01:30:00 8.2 0.8 9.9 5.7 8.1 0.8 9.9 6.1 18 6 18 305 36.4 4.2 43.8 20.7 01/26/2006 01:40:00 7.2 0.8 9.1 5.3 7.1 0.8 9.1 5.3 19 6 14 305 40 2.7 44.5 20.1 01/26/2006 01:50:00 7.7 0.6 9.5 6.1 7.6 0.6 9.1 6.1 21 6 25 305 38.8 6.2 52.9 22.8 01/26/2006 02:00:00 7.7 0.6 9.1 5.7 7.7 0.7 9.5 5.7 19 6 14 305 47 6.2 52.9 20.7 01/26/2006 02:10:00 7.6 0.7 9.1 4.9 7.5 0.8 8.8 4.9 23 5 14 305 46.7 6.7 52.9 17.3 01/26/2006 02:20:00 7.2 0.8 9.1 5.3 7.1 0.9 9.5 5.3 20 6 15 305 44.5 9.5 52.9 13.7 01/26/2006 02:30:00 7.3 0.5 9.1 5.7 7.2 0.5 8.8 6.1 23 5 19 305 42 8.7 52.9 20.4 01/26/2006 02:40:00 6.3 0.7 8 4.2 6.1 0.7 8 4.6 26 7 30 305 41.7 5.9 51.4 19.6 01/26/2006 02:50:00 6.4 0.6 8 4.6 6.3 0.7 8.4 4.6 26 6 31 305 46.3 3.7 49.9 3.4 01/26/2006 03:00:00 7.2 0.6 8.8 5.7 7 0.7 8.8 4.9 28 5 23 305 37.2 9.5 52.9 3.7 01/26/2006 03:10:00 7.7 0.6 9.1 5.7 7.5 0.6 9.1 6.1 27 6 30 305 43.1 5.6 51 27.3 01/26/2006 03:20:00 7.2 0.8 9.1 5.3 7 0.8 8.8 5.3 27 8 37 305 43.3 7.6 52.9 19.9 01/26/2006 03:30:00 7.5 0.6 9.5 5.7 7.4 0.6 9.1 5.7 25 5 26 305 44.1 6.4 52.9 21.9 01/26/2006 03:40:00 7.7 0.6 9.5 6.1 7.6 0.7 9.1 6.1 21 4 22 305 36.8 8 51.8 20.4 01/26/2006 03:50:00 6.9 0.8 8.8 4.9 6.8 0.8 8.4 5.3 25 6 25 305 45.1 6.4 52.9 17.9 01/26/2006 04:00:00 7.1 0.6 8.4 4.9 7 0.6 8.4 5.3 25 5 28 305 42.2 7 51.8 17.6 01/26/2006 04:10:00 7.3 0.6 8.8 5.3 7.3 0.7 9.1 5.7 25 6 11 305 42 8.7 52.9 19.3 01/26/2006 04:20:00 8.2 0.7 9.9 6.1 8.3 0.8 10.7 6.5 16 7 13 305 45.4 4.5 52.5 27.6 01/26/2006 04:30:00 8.1 0.7 10.3 6.1 8 0.8 9.9 6.1 16 6 22 305 43.6 8.7 52.9 25.5 01/26/2006 04:40:00 8.8 0.7 11.1 6.8 8.7 0.8 10.7 6.5 17 6 15 305 44.7 8.7 52.9 15.6 01/26/2006 04:50:00 9 1 11.5 6.8 8.9 0.9 11.1 6.8 18 5 14 305 44.8 6.7 52.9 8.7 01/26/2006 05:00:00 9 0.7 10.7 6.8 9 0.8 11.1 6.8 14 6 16 305 41.9 8.7 50.3 3.4 01/26/2006 05:10:00 8.4 0.7 9.9 6.1 8.3 0.8 10.3 6.5 17 8 16 305 42.8 6.7 52.1 16.2 01/26/2006 05:20:00 8 0.8 9.5 6.5 8 0.8 10.3 6.1 11 7 8 305 43.3 6.2 49.2 16.7 01/26/2006 05:30:00 8.5 0.9 9.9 6.1 8.4 0.9 10.3 5.7 6 5 8 305 35.9 9.9 48.8 -4 01/26/2006 05:40:00 8.2 0.7 9.5 6.1 8.2 0.8 9.9 5.7 7 5 6 305 32.1 10.8 43.1 -9.2 01/26/2006 05:50:00 7.8 0.9 10.7 5.3 7.7 1 10.3 4.9 7 7 1 305 39.2 10.8 52.9 -5.6 01/26/2006 06:00:00 8.3 1.3 11.1 4.6 8.2 1.4 11.5 4.9 7 7 358 305 40.1 11.3 52.9 14.3 01/26/2006 06:10:00 9.5 0.8 11.1 7.2 9.5 0.9 12.2 7.2 8 5 9 305 26.9 15.3 49.9 -8.2 01/26/2006 06:20:00 8.9 1 11.5 6.5 8.9 1.1 11.1 6.1 9 8 21 305 21.9 9.1 30.4 -8.2 01/26/2006 06:30:00 9.8 0.6 11.1 8 9.7 0.8 11.8 7.6 14 5 14 305 40.4 12.9 52.9 -7.7 01/26/2006 06:40:00 10.8 1 12.6 7.6 10.7 1 13 8 8 5 8 305 46.6 1.6 51.4 34.3 01/26/2006 06:50:00 9.3 1.1 11.8 6.5 9.2 1.2 12.6 6.1 7 5 3 305 45.5 1.6 49.5 38.9 01/26/2006 07:00:00 9.2 0.8 11.1 6.8 9.3 1 11.5 6.5 5 5 9 305 40.3 9.9 51.4 18.1 01/26/2006 07:10:00 10.2 0.8 11.8 7.2 10.1 0.8 12.2 7.6 13 4 10 305 31.4 8.3 50.6 8.7 01/26/2006 07:20:00 9 1.2 11.5 5.7 9 1.3 11.8 5.7 10 6 9 305 42.8 3.8 51 30.7 01/26/2006 07:30:00 9.1 1 11.1 6.5 9.2 1.1 11.5 6.5 10 6 10 305 39.3 10.8 51.4 6.1 01/26/2006 07:40:00 9 0.7 10.7 7.2 8.9 0.8 10.7 6.5 16 5 10 305 38.8 9.9 49.5 5.2 01/26/2006 07:50:00 9.2 0.9 10.7 6.5 9.2 1 11.1 6.8 14 5 25 305 27.8 5 34.6 -11.9 01/26/2006 08:00:00 8.9 0.8 10.7 6.5 8.9 1 10.7 6.5 13 5 11 305 33 11.3 47.7 0.8 01/26/2006 08:10:00 8.5 0.9 10.3 6.1 8.5 1 10.7 6.1 10 5 13 305 38.8 5.6 49.5 20.7 01/26/2006 08:20:00 8.8 0.8 10.3 6.8 8.9 1 11.1 6.5 3 6 11 305 46.9 3.2 51.4 34.9 01/26/2006 08:30:00 8.4 0.8 10.3 6.5 8.4 0.9 10.3 6.5 4 6 3 305 46.8 1.9 51 39.6 01/26/2006 08:40:00 8.5 0.8 10.3 6.1 8.5 1 10.7 6.1 8 6 1 305 42.3 5.2 49.9 24.3 01/26/2006 08:50:00 8.1 0.7 9.5 6.1 8 0.8 9.9 6.1 14 6 16 305 41.8 3.4 47 24.6 01/26/2006 09:00:00 8 0.8 9.1 5.3 7.8 0.8 9.5 6.1 17 5 20 305 35.7 7.6 52.5 19.6 01/26/2006 09:10:00 7.3 0.7 8.8 5.7 7.2 0.7 8.8 5.3 11 7 17 305 44.9 2.1 50.3 37.9 01/26/2006 09:20:00 8.4 0.5 9.9 6.8 8.6 0.7 10.3 6.5 5 4 2 305 41.3 5.4 49.5 20.7 01/26/2006 09:30:00 8.9 0.6 10.3 6.5 9 0.8 10.3 6.1 6 4 11 305 41.2 6.7 50.3 20.4 01/26/2006 09:40:00 8.5 0.8 9.9 6.5 8.4 0.8 10.3 6.5 9 4 8 305 44.1 3.5 49.9 34.3 01/26/2006 09:50:00 8.2 0.8 9.9 5.7 8 1 10.3 5.7 12 6 18 305 40 6.7 48.8 25.5 01/26/2006 10:00:00 8.3 0.7 9.9 6.1 8.3 0.8 10.3 6.1 16 4 21 305 38.8 7.3 47.3 24.9 01/26/2006 10:10:00 8.7 0.7 10.3 6.8 8.6 0.9 10.7 6.5 14 5 13 305 44.9 1.8 47 40.3 01/26/2006 10:20:00 8.2 1 9.9 5.3 8.2 1 10.3 5.7 13 5 11 305 40.6 1.5 45.9 38.6 01/26/2006 10:30:00 8.5 0.7 9.9 6.1 8.5 0.9 10.3 6.1 14 4 17 305 39.5 0.9 41.3 31.7 01/26/2006 10:40:00 8.1 0.9 9.5 5.3 7.9 1 9.9 5.7 14 5 16 305 33.3 5.2 42 13.7 01/26/2006 10:50:00 7.6 0.7 9.1 4.9 7.4 0.7 9.1 5.3 15 5 13 305 43 2.6 46.3 31 01/26/2006 11:00:00 6.8 1.1 9.1 4.9 6.7 1.2 9.5 4.6 17 5 14 305 42.8 1.1 45.2 37.2 01/26/2006 11:10:00 7.6 0.7 9.1 4.9 7.4 0.8 9.5 4.9 14 6 18 305 42.3 1.4 44.8 37.6 01/26/2006 11:20:00 6.5 0.8 8.4 4.6 6.4 0.8 8 4.6 18 5 11 305 42.2 1.1 44.5 37.9 01/26/2006 11:30:00 7.2 0.9 9.5 5.3 7.1 1 9.5 4.9 14 5 12 305 42 1.5 46.3 37.6 01/26/2006 11:40:00 8.6 0.5 9.5 6.1 8.8 0.7 10.3 6.5 11 4 7 305 43.5 1.5 46.3 39.6 01/26/2006 11:50:00 7.5 1 9.1 5.3 7.4 1 9.1 4.9 14 5 12 305 43.4 1.7 46.3 36.2 01/26/2006 12:00:00 7.1 0.9 8.8 4.9 6.9 0.9 8.4 4.6 11 5 13 305 35.9 8 46.6 23.4 01/26/2006 12:10:00 6.8 0.7 8.8 5.3 6.6 0.7 8.4 4.9 14 5 11 305 31.8 3.1 36.9 24.9 01/26/2006 12:20:00 6.7 0.8 8.8 4.6 6.6 0.8 8.8 4.6 12 6 16 305 32.6 2.5 36.6 23.7 01/26/2006 12:30:00 6.9 0.7 8.4 5.3 6.7 0.7 8 4.9 14 6 21 305 31.7 2.3 35.9 25.2 01/26/2006 12:40:00 7.1 0.9 8.8 4.9 7.1 1 9.1 4.9 9 5 12 305 35.7 5.2 42.4 25.2 01/26/2006 12:50:00 6.9 0.8 8.8 4.6 6.8 0.8 8.8 4.6 13 6 18 305 35 8.7 44.8 11.6 01/26/2006 13:00:00 6.9 0.7 8.4 4.9 6.7 0.8 8.4 4.9 16 5 14 305 32.3 9.9 43.1 7.4 01/26/2006 13:10:00 7.1 0.8 8.8 4.9 7 0.9 9.1 4.6 10 4 9 305 23.7 6.7 45.5 -10.4 01/26/2006 13:20:00 6.9 0.9 8.8 4.9 6.8 0.9 8.8 4.9 11 6 15 305 31.4 5.4 47.3 12.1 01/26/2006 13:30:00 6.8 0.6 8.4 4.9 6.7 0.7 8.8 4.9 16 6 20 305 30 7.6 37.9 3.7 01/26/2006 13:40:00 6.1 0.9 8 3.8 6 0.9 8 3.8 16 5 18 305 33.8 7.6 44.8 12.9 01/26/2006 13:50:00 6.1 0.7 7.6 3.8 5.9 0.7 7.2 3.8 15 6 13 305 30.6 6.4 40.3 15.1 01/26/2006 14:00:00 7.2 0.8 9.1 5.3 7 0.9 9.5 4.6 15 6 13 305 29.7 6.4 42.4 3.7 01/26/2006 14:10:00 7.1 0.7 8.8 4.9 6.9 0.8 8.4 4.6 7 5 4 305 23.9 2.7 28.8 1.7 01/26/2006 14:20:00 7.7 0.6 9.1 5.7 7.5 0.7 8.8 5.3 9 4 9 305 22.7 4.2 27.3 -21.3 01/26/2006 14:30:00 7.3 0.7 8.8 5.3 7.2 0.7 8.8 5.7 8 5 10 305 37.6 5.2 44.8 16.5 01/26/2006 14:40:00 7.5 0.6 8.8 6.1 7.4 0.6 8.8 5.7 9 4 10 305 36 5.2 44.1 19.6 01/26/2006 14:50:00 8 0.5 9.1 6.5 8 0.6 9.1 6.5 11 4 13 305 29.5 7.3 43.4 12.1 01/26/2006 15:00:00 7.6 0.7 9.5 5.3 7.5 0.8 9.1 5.3 12 4 12 305 18.7 7.6 29.5 -2.7 01/26/2006 15:10:00 7.5 0.7 9.1 5.7 7.2 0.7 8.8 4.9 9 6 13 305 26.4 5.6 35.9 11.3 01/26/2006 15:20:00 6.6 0.9 8.8 4.9 6.4 0.9 8.8 4.6 8 5 10 305 34.8 3.5 39.6 20.7 01/26/2006 15:30:00 7.7 0.9 9.1 4.9 7.6 1 9.1 4.6 8 4 5 305 32.6 4 38.6 12.6 01/26/2006 15:40:00 6.7 0.7 8.8 4.9 6.5 0.7 8.4 4.9 12 5 13 305 35.3 4.4 44.8 17 01/26/2006 15:50:00 6.9 0.6 8 4.9 6.6 0.6 8 4.9 14 6 9 305 39.4 5.2 44.8 11.3 01/26/2006 16:00:00 6.4 0.7 8.4 4.6 6.2 0.8 8.4 4.6 22 6 21 305 35.1 9.1 47.7 10 01/26/2006 16:10:00 7.3 0.5 8.8 6.1 7.1 0.6 8.4 5.7 20 5 16 305 37.8 5.9 44.8 2.7 01/26/2006 16:20:00 7.7 0.6 9.1 5.7 7.6 0.6 9.1 5.7 16 4 22 305 36.9 9.1 48.8 1.5 01/26/2006 16:30:00 7.8 0.7 9.1 5.7 7.7 0.8 9.9 5.7 17 5 14 305 42 7 50.6 7.7 01/26/2006 16:40:00 7.6 0.6 8.8 5.7 7.4 0.6 8.8 5.3 19 4 18 305 39.3 7 48.4 8.2 01/26/2006 16:50:00 7.3 0.6 8.8 5.7 7 0.7 8.8 5.3 15 5 10 305 42.9 6.4 52.9 21.6 01/26/2006 17:00:00 7.1 0.6 9.1 5.3 6.8 0.7 9.1 4.9 16 5 16 305 27.4 5 34.3 1.7 01/26/2006 17:10:00 7.1 0.6 8.4 5.3 6.9 0.6 8.4 5.3 17 5 21 305 29.4 4 35.3 11 01/26/2006 17:20:00 6.9 0.6 8.4 5.3 6.6 0.6 8 5.3 15 4 16 305 27.4 5.9 40.6 8.2 01/26/2006 17:30:00 6.5 0.8 8.4 4.6 6.3 0.8 8.4 4.2 14 5 14 305 29.5 7.3 43.8 -12.1 01/26/2006 17:40:00 6.5 0.7 8 4.2 6.3 0.7 8 4.9 13 5 9 305 34.8 7.3 48.4 -13.7 01/26/2006 17:50:00 6.1 0.9 8 3.8 5.8 0.8 8 4.2 20 7 19 305 40.2 6.7 47 -13.7 01/26/2006 18:00:00 7.4 0.8 9.1 5.3 7.3 0.9 9.1 4.9 10 4 11 305 33.5 8.3 45.9 -0.1 01/26/2006 18:10:00 6.9 1 8.8 4.2 6.7 1.1 9.1 4.2 11 7 9 305 29.6 12.3 47.7 -21.3 01/26/2006 18:20:00 6.1 0.7 7.6 4.2 6 0.8 8 3.8 16 6 15 305 40.6 4.7 48.8 17.9 01/26/2006 18:30:00 7.5 0.5 8.4 6.1 7.4 0.5 8.8 6.1 10 5 13 305 33.8 5 41 2.2 01/26/2006 18:40:00 6.9 1 8.8 4.6 6.7 1 8.8 4.2 12 8 4 305 33.9 2.8 40.3 24.3 01/26/2006 18:50:00 6.4 0.7 8.4 4.6 6.2 0.8 8 4.6 23 7 14 305 34.4 5 42 6.7 01/26/2006 19:00:00 8 0.6 9.1 6.1 8 0.7 9.5 6.1 11 4 12 305 39.9 3.5 46.6 27.6 01/26/2006 19:10:00 7.2 0.8 8.8 4.9 6.9 0.8 8.8 4.9 12 6 12 305 39.4 5 46.3 23.1 01/26/2006 19:20:00 6.8 0.5 8 4.9 6.5 0.6 8 4.6 14 5 12 305 42.5 5.2 49.2 -4.5 01/26/2006 19:30:00 6.9 0.8 8.4 4.6 6.8 0.8 8.4 4.9 10 5 11 305 36.7 6.7 45.2 -9.4 01/26/2006 19:40:00 7.1 0.6 8.8 5.7 7 0.6 8.4 5.3 11 4 14 305 39.4 2.9 45.9 29.8 01/26/2006 19:50:00 5.4 0.8 6.8 3.4 5.1 0.8 6.8 3 18 6 14 305 39.8 3.1 46.3 24 01/26/2006 20:00:00 5.4 0.6 6.8 3.8 5.2 0.6 6.8 3.4 14 6 21 305 41.5 2.7 47 31.7 01/26/2006 20:10:00 5.3 0.6 6.8 3.8 5.1 0.6 6.5 3.8 17 6 28 305 39.8 5.6 47.7 0.6 01/26/2006 20:20:00 7 0.7 8.4 4.9 6.8 0.7 8.4 4.9 11 6 20 305 40.5 3.7 46.3 31 01/26/2006 20:30:00 6.1 0.7 7.6 4.2 5.9 0.7 7.6 4.2 11 5 12 305 40.4 4 46.6 28.8 01/26/2006 20:40:00 6.8 0.5 8 5.3 6.6 0.6 8 4.9 10 5 1 305 32.6 8 50.6 -9.2 01/26/2006 20:50:00 6.5 0.6 8 4.9 6.4 0.7 8 4.6 10 3 10 305 32.9 4 38.6 7.7 01/26/2006 21:00:00 5.8 0.5 6.8 4.6 5.6 0.5 6.8 4.2 15 4 19 305 33.3 5.2 39.6 -11.1 01/26/2006 21:10:00 5.9 0.6 7.2 4.2 5.5 0.8 7.2 3.8 12 5 12 305 31 6.4 40.6 0.1 01/26/2006 21:20:00 6 0.5 7.2 4.6 5.7 0.6 6.8 3.4 16 6 11 305 33 4.7 40.6 20.7 01/26/2006 21:30:00 6 0.5 7.2 4.6 5.9 0.5 7.2 4.6 18 5 12 305 33.5 4.7 39.6 -1.1 01/26/2006 21:40:00 6.2 0.5 7.2 4.9 6 0.6 7.2 4.6 17 5 22 305 31.8 6.2 38.9 3.2 01/26/2006 21:50:00 6.1 0.6 7.6 4.6 5.9 0.7 7.2 4.2 22 5 14 305 31.8 6.4 40.3 -2.7 01/26/2006 22:00:00 5.5 0.6 6.8 4.2 5.2 0.6 6.8 4.2 26 5 29 305 30.1 10.4 40.6 -11.1 01/26/2006 22:10:00 5.6 0.7 6.8 3.8 5.3 0.7 7.2 3.8 25 5 27 305 33.6 5.2 39.6 -5.1 01/26/2006 22:20:00 5.2 0.5 6.5 3.8 4.9 0.5 6.5 3.4 24 5 17 305 26.3 10.4 39.6 -12.3 01/26/2006 22:30:00 5 0.5 6.1 3.8 4.8 0.5 6.1 3.8 29 5 28 305 32.2 6.7 39.6 -2.7 01/26/2006 22:40:00 5 0.4 6.1 4.2 4.7 0.3 5.7 3.8 26 4 24 305 30.4 7.6 37.9 -20.1 01/26/2006 22:50:00 5 0.4 6.5 4.2 4.8 0.5 6.1 3.4 23 6 19 305 32 5.6 38.3 4.4 01/26/2006 23:00:00 5.5 0.6 7.2 3.8 5.3 0.6 7.2 3.8 10 6 14 305 31.6 5.6 37.6 0.6 01/26/2006 23:10:00 5.5 0.7 7.2 3.8 5.4 0.7 6.8 3.8 9 6 13 305 29.2 7.3 37.9 -7.1 01/26/2006 23:20:00 5.9 0.7 7.6 3.8 5.7 0.7 7.2 3.8 4 6 8 305 32.9 4.7 38.9 4.4 01/26/2006 23:30:00 5.4 0.7 7.6 3.8 5.3 0.7 7.2 3.8 9 8 11 305 27.1 9.1 37.9 -1.8 01/26/2006 23:40:00 5.6 0.7 7.6 3.8 5.4 0.7 7.6 3.4 10 6 7 305 19.9 6.4 33.6 1.5 01/26/2006 23:50:00 6.2 0.6 7.6 4.9 6 0.6 7.6 4.2 16 5 10 305 26.1 5 32.6 -0.4 01/27/2006 00:00:00 5.5 0.9 7.6 3.8 5.4 0.9 7.6 3.4 12 5 20 305 28.7 2.7 34.3 10.2 01/27/2006 00:10:00 6 0.7 7.6 4.2 5.8 0.9 7.2 3.8 15 5 15 305 29.1 2.9 34.9 20.1 01/27/2006 00:20:00 6.4 0.6 8 4.6 6.3 0.6 8 4.9 7 7 17 305 28.8 3.8 35.3 9.2 01/27/2006 00:30:00 5.8 0.8 7.6 4.2 5.6 0.8 7.6 3.8 357 5 349 305 28.4 2.9 33.6 17.9 01/27/2006 00:40:00 6.3 0.6 7.6 4.2 6.2 0.6 7.6 4.2 359 4 1 305 27.4 3.5 35.6 16.2 01/27/2006 00:50:00 6.1 0.6 7.6 4.6 6 0.6 7.6 4.9 1 7 355 305 29.9 4.4 36.2 13.7 01/27/2006 01:00:00 5.9 0.7 7.2 3.8 5.9 0.7 7.6 4.2 1 5 3 305 28.9 3.7 35.6 15.3 01/27/2006 01:10:00 5.9 0.7 7.2 4.2 5.8 0.7 7.6 4.2 359 6 347 305 24.6 4.2 31.4 7.4 01/27/2006 01:20:00 5.9 0.6 7.2 4.2 5.8 0.6 6.8 4.2 0 6 9 305 20.9 6.2 27.3 3.2 01/27/2006 01:30:00 5.3 0.5 6.5 3.8 5.2 0.6 6.8 3.8 0 6 7 305 23.4 3.8 31.4 4.9 01/27/2006 01:40:00 6.3 0.7 7.6 4.9 6.2 0.8 7.6 4.2 359 5 357 305 32.2 3.8 36.6 0.1 01/27/2006 01:50:00 5.9 0.5 7.2 4.6 5.8 0.6 7.2 4.2 1 4 4 305 30.9 3.1 34.3 13.7 01/27/2006 02:00:00 5.4 0.5 6.8 4.2 5.1 0.5 6.5 3.8 3 5 4 305 31.8 2.6 36.2 17.3 01/27/2006 02:10:00 5.2 0.6 6.5 3.8 4.9 0.5 6.5 3.4 8 5 9 305 30.6 3.5 34.6 11.3 01/27/2006 02:20:00 5.3 0.6 7.2 3.8 5.1 0.7 6.8 3.4 11 6 6 305 31.8 2.8 36.2 15.3 01/27/2006 02:30:00 6.3 0.6 7.6 4.9 6.2 0.6 7.6 4.6 8 4 9 305 30.4 2.6 33.9 6.7 01/27/2006 02:40:00 5.8 0.5 6.8 4.2 5.6 0.6 7.2 4.2 8 4 11 305 29.3 4.5 34.6 9.7 01/27/2006 02:50:00 5.1 0.5 6.5 3.8 5 0.5 6.1 3.8 5 4 3 305 25.8 7 33 0.6 01/27/2006 03:00:00 5.5 0.7 6.8 3.8 5.3 0.7 7.2 3.8 2 6 3 305 27 3.1 32 15.6 01/27/2006 03:10:00 5.3 0.6 7.2 3.8 5.1 0.6 7.2 3.8 3 6 1 305 21 8 30.4 -6.2 01/27/2006 03:20:00 6 0.9 7.6 3.4 6 0.8 7.6 3.8 5 5 3 305 22.2 6.2 31 2.2 01/27/2006 03:30:00 5.6 0.8 7.2 3.4 5.5 0.8 7.2 3.4 3 4 356 305 24.4 3.1 31.7 6.4 01/27/2006 03:40:00 5.6 0.9 7.2 3.4 5.4 1 7.6 3.4 1 6 6 305 25.1 3.8 31.7 6.9 01/27/2006 03:50:00 6.4 0.7 8 4.6 6.2 0.7 7.6 4.6 2 4 0 305 26.9 3.2 33.3 7.7 01/27/2006 04:00:00 6.3 0.8 8.4 4.2 6.3 0.9 8.4 4.6 355 8 345 305 29.7 4 39.6 15.3 01/27/2006 04:10:00 5.9 0.7 7.2 4.6 5.7 0.7 7.6 3.8 2 6 7 305 35.3 3.4 39.3 15.3 01/27/2006 04:20:00 6.9 0.6 8.4 5.3 6.8 0.7 8.4 4.6 1 4 0 305 27.7 2.6 37.6 15.9 01/27/2006 04:30:00 6.6 0.8 8 4.6 6.4 0.8 8 4.2 1 5 5 305 27.1 2.7 32 14.3 01/27/2006 04:40:00 7 0.7 8.4 4.6 6.9 0.7 8.4 4.6 0 4 0 305 29.8 5 39.6 17.3 01/27/2006 04:50:00 7 0.8 8.8 4.9 6.8 0.9 8.8 4.6 358 5 356 305 31.4 7.6 40 3.4 01/27/2006 05:00:00 6.4 0.7 8.4 4.2 6.3 0.7 8.4 4.6 4 5 359 305 30.6 8.7 38.9 2.2 01/27/2006 05:10:00 7.7 0.8 9.5 5.7 7.6 0.9 9.9 5.7 0 5 3 305 33.5 7.6 41.3 3.2 01/27/2006 05:20:00 6.7 0.7 8 4.9 6.5 0.7 8.4 4.9 0 6 10 305 31.3 7.3 37.9 3.2 01/27/2006 05:30:00 7.5 0.8 9.1 4.9 7.5 0.9 9.1 5.3 2 6 10 305 23.6 8.7 37.6 -19.7 01/27/2006 05:40:00 8.1 0.8 9.9 5.7 8 0.8 9.5 5.7 3 5 4 305 28.3 5.6 37.2 3.7 01/27/2006 05:50:00 7.4 0.7 8.8 5.7 7.2 0.8 9.1 5.3 359 6 359 305 30.1 5.6 37.6 3.4 01/27/2006 06:00:00 7.4 0.7 9.1 6.1 7.3 0.8 9.1 5.3 3 5 358 305 22.5 10.4 38.6 2.2 01/27/2006 06:10:00 7.3 0.8 9.1 5.3 7.1 1 9.1 4.9 3 6 359 305 30.4 6.2 38.9 4.7 01/27/2006 06:20:00 6.8 1 8.8 4.2 6.6 1 8.8 3.8 4 5 10 305 27 10.4 39.3 -19.5 01/27/2006 06:30:00 6.6 0.6 8 5.3 6.5 0.6 8 4.6 1 7 4 305 27 10.4 45.9 -19.7 01/27/2006 06:40:00 6.1 0.7 7.6 4.6 5.9 0.7 8 4.6 358 7 356 305 42.2 5 50.3 24.6 01/27/2006 06:50:00 5.8 0.7 7.2 4.2 5.7 0.8 7.6 4.2 1 10 0 305 42.7 3.4 48.4 17.3 01/27/2006 07:00:00 5.6 0.8 7.6 3.8 5.6 0.8 7.6 3.8 352 8 3 305 34.8 10.8 47.3 -7.1 01/27/2006 07:10:00 6 0.6 7.2 4.6 5.9 0.6 7.2 4.6 6 6 15 305 39.5 6.2 46.6 1.3 01/27/2006 07:20:00 6 0.6 7.6 4.6 5.8 0.6 7.2 4.2 10 5 10 305 40.3 5.6 45.9 -19.3 01/27/2006 07:30:00 5.8 0.7 7.2 4.2 5.8 0.7 7.2 4.2 3 8 11 305 37.5 5.6 44.8 2.9 01/27/2006 07:40:00 5.3 0.6 7.2 3.8 5.3 0.6 6.8 3.8 358 9 342 305 34.9 5.2 43.8 18.1 01/27/2006 07:50:00 5.8 0.6 7.2 4.2 5.7 0.7 7.6 4.2 6 8 354 305 35.7 5.6 43.8 8.7 01/27/2006 08:00:00 5 0.9 7.6 3.4 4.9 0.9 6.8 3 2 9 1 305 36.7 4 43.1 15.3 01/27/2006 08:10:00 5.1 0.6 6.5 3.4 5 0.6 6.5 3.4 13 8 5 305 35.4 5.2 42.7 14 01/27/2006 08:20:00 4.8 0.7 6.1 2.6 4.7 0.6 6.5 3 17 7 21 305 37.6 3.5 43.1 21.9 01/27/2006 08:30:00 4.9 1 7.6 3 4.9 1.1 7.6 2.6 7 10 355 305 36.7 3.5 42 9.2 01/27/2006 08:40:00 4.9 0.8 7.2 3 4.9 0.8 7.2 3 10 7 17 305 37.6 3.1 42.4 27.9 01/27/2006 08:50:00 5.1 0.8 7.2 3 5.1 0.8 6.8 3 0 9 25 305 38 1.9 40.6 26.4 01/27/2006 09:00:00 5.2 0.9 7.2 3.4 5.1 0.9 7.2 3 5 6 5 305 31 5 39.6 14.8 01/27/2006 09:10:00 5.1 0.6 6.8 3.4 5.1 0.6 7.2 3.4 357 7 5 305 31.4 5.2 37.9 19.6 01/27/2006 09:20:00 5.2 0.7 7.2 3.4 5.1 0.7 7.2 3 6 6 16 305 32.3 3.8 38.6 16.7 01/27/2006 09:30:00 4.5 0.6 6.5 3 4.4 0.6 6.5 3 359 8 351 305 31.7 2.8 37.9 11.3 01/27/2006 09:40:00 5.4 0.6 7.2 4.2 5.4 0.7 7.2 3.8 358 8 9 305 32.9 3.8 41.7 19.6 01/27/2006 09:50:00 5.3 0.6 6.8 4.2 5.2 0.7 6.8 3.8 11 11 22 305 33.7 4.5 42.4 14.8 01/27/2006 10:00:00 5.5 0.9 7.2 3.4 5.3 0.9 6.8 3 13 5 6 305 37.2 2.7 45.2 27 01/27/2006 10:10:00 5.5 0.5 6.8 3.8 5.4 0.6 6.5 3.8 10 8 14 305 39.7 2.5 43.8 29.8 01/27/2006 10:20:00 6 0.5 6.8 4.6 5.9 0.5 7.2 4.2 16 6 21 305 35.9 4.7 42.4 26.1 01/27/2006 10:30:00 5.7 0.5 6.8 4.2 5.6 0.6 6.8 4.2 9 8 5 305 30.9 1.5 33.3 23.4 01/27/2006 10:40:00 4.9 0.8 7.6 3.4 4.7 0.8 7.2 3 21 8 26 305 30.3 1.4 32.6 19 01/27/2006 10:50:00 4.5 0.6 6.1 3 4.4 0.6 6.1 2.6 20 9 19 305 19.3 3.5 29.8 8.2 01/27/2006 11:00:00 6 0.6 7.6 4.2 6 0.6 7.6 4.6 9 4 8 305 22.7 5.2 31.7 6.7 01/27/2006 11:10:00 5.8 0.7 7.2 4.2 5.7 0.8 7.2 3.8 14 6 18 305 26.7 3.1 32.3 11.8 01/27/2006 11:20:00 6.2 0.6 7.2 4.2 6 0.6 7.2 4.2 12 4 13 305 23.2 2 27.3 10.5 01/27/2006 11:30:00 5.5 0.6 6.8 3.8 5.4 0.6 6.8 3.8 16 4 17 305 21.7 4.2 27.3 -0.8 01/27/2006 11:40:00 4.7 0.4 6.1 3.4 4.4 0.4 5.7 3.4 17 6 12 305 28.7 2.7 33.3 11.8 01/27/2006 11:50:00 5.2 0.4 6.1 4.2 5 0.4 6.1 3.8 22 6 24 305 27.5 4.2 31.7 12.4 01/27/2006 12:00:00 5.4 0.4 6.8 4.2 5.3 0.5 6.8 4.2 19 4 19 305 20.3 3.7 28.2 14.8 01/27/2006 12:10:00 4.8 0.5 6.1 3.4 4.6 0.5 6.1 3 21 5 12 305 32.5 6.2 39.6 14.5 01/27/2006 12:20:00 4.3 0.5 5.3 3 4.2 0.4 5.3 3 20 3 16 305 29.8 6.2 39.3 10 01/27/2006 12:30:00 4 0.5 5.3 2.6 3.9 0.5 5.3 2.6 20 7 16 305 36.2 3.5 40 23.4 01/27/2006 12:40:00 3.7 0.6 6.1 2.3 3.5 0.7 6.1 2.6 19 11 354 305 36 4.7 42.4 26.1 01/27/2006 12:50:00 5.3 0.6 6.5 3.4 5.1 0.6 6.5 3.4 7 6 13 305 37.2 1.1 39.3 28.5 01/27/2006 13:00:00 5.3 0.6 6.8 3.8 5.2 0.7 6.5 3.8 2 8 14 305 29.9 3.4 38.6 25.2 01/27/2006 13:10:00 5.2 0.5 6.5 3.8 5.2 0.5 6.1 3.8 3 5 8 305 23.9 5.6 32.6 2.7 01/27/2006 13:20:00 4.7 0.5 5.7 3.4 4.7 0.5 6.1 3.4 0 5 4 305 26.4 8 38.3 -6.7 01/27/2006 13:30:00 4.3 0.5 5.7 3 4.3 0.6 5.7 3 350 9 7 305 33 3.2 37.2 23.4 01/27/2006 13:40:00 4.9 1 6.8 3 5 1 6.8 3 339 5 340 305 31 3.7 36.2 21.9 01/27/2006 13:50:00 5.1 0.5 6.1 3.8 5.1 0.5 6.5 3.8 338 6 338 305 32.7 3.8 38.3 24 01/27/2006 14:00:00 5.3 0.7 6.8 3.4 5.3 0.6 6.5 3.8 340 6 334 305 26 5.4 38.6 14.3 01/27/2006 14:10:00 5 0.6 6.5 3.4 4.7 0.6 6.1 3 318 33 305 305 32.1 3.4 36.2 22.5 01/27/2006 14:20:00 5.3 0.4 6.1 4.2 5 0.4 6.1 3.8 318 41 305 305 27.2 2.6 31.7 17.3 01/27/2006 14:30:00 5.3 0.4 6.1 4.2 5.1 0.5 6.1 3.8 316 32 311 305 27.4 2.4 31.7 14.5 01/27/2006 14:40:00 5.6 0.5 6.8 4.2 5.3 0.5 6.5 4.2 314 32 70 305 29.7 1.8 33.3 15.9 01/27/2006 14:50:00 6 0.5 7.2 4.9 5.7 0.4 6.8 4.6 311 30 302 305 31.2 4.4 42 21.9 01/27/2006 15:00:00 5.6 0.5 6.8 4.6 5.3 0.6 6.8 4.2 312 36 352 305 32 3.7 41 23.7 01/27/2006 15:10:00 5.7 0.5 6.8 4.6 5.3 0.5 6.5 4.2 313 36 303 305 35.7 4 42.7 22.2 01/27/2006 15:20:00 5.6 0.4 6.8 4.6 5.3 0.4 6.5 4.2 307 32 299 305 35.3 1.2 38.6 32.3 01/27/2006 15:30:00 5.3 0.5 6.5 4.2 5 0.5 6.1 3.8 308 32 303 305 29.6 6.4 36.6 13.4 01/27/2006 15:40:00 5.7 0.4 6.8 4.6 5.3 0.5 6.5 4.2 305 23 302 305 31.8 4.5 36.6 10 01/27/2006 15:50:00 5.3 0.5 6.5 4.2 5 0.5 6.5 3.8 313 36 303 305 37.9 5.9 48.1 29.8 01/27/2006 16:00:00 5.7 0.6 7.2 4.2 5.4 0.6 6.8 4.2 309 24 303 305 41.3 2.8 45.5 26.7 01/27/2006 16:10:00 5.8 0.5 6.8 4.6 5.6 0.5 6.8 3.8 316 28 310 305 39.4 4.2 45.9 27.6 01/27/2006 16:20:00 5.9 0.7 7.2 4.2 5.7 0.7 6.8 3.8 313 22 312 305 24.5 5.9 38.3 11.3 01/27/2006 16:30:00 5.6 0.5 6.8 4.2 5.5 0.6 6.8 4.2 317 15 136 305 26.8 4.7 38.9 17 01/27/2006 16:40:00 5.5 0.8 8 3.8 5.4 0.8 7.6 3.8 334 11 327 305 25 4.2 37.9 16.7 01/27/2006 16:50:00 6.5 0.7 8 4.9 6.4 0.8 8.4 4.6 344 9 351 305 31.4 7.6 41.3 -4.9 01/27/2006 17:00:00 6.1 0.8 8 4.2 6.2 0.7 8.4 4.6 352 6 359 305 39.1 5.2 46.3 15.6 01/27/2006 17:10:00 6.7 0.7 8 4.9 6.7 0.7 8 4.9 353 7 352 305 33.6 3.5 42 23.1 01/27/2006 17:20:00 6.4 0.7 8 4.2 6.4 0.7 8.4 4.2 348 6 336 305 36.4 2.2 40.3 26.7 01/27/2006 17:30:00 6.3 0.9 8.4 4.2 6.3 1 8.4 4.6 357 5 2 305 37.9 5 47.3 17.9 01/27/2006 17:40:00 7.2 0.7 8.8 5.7 7.2 0.7 8.8 5.3 354 6 351 305 40.8 3.1 44.8 25.8 01/27/2006 17:50:00 7.2 0.8 8.8 4.2 7.2 0.9 9.5 4.9 353 5 350 305 41 4.2 45.9 26.4 01/27/2006 18:00:00 7.4 0.9 9.5 4.6 7.4 1 9.5 4.9 354 6 1 305 38.7 5.9 46.6 19.9 01/27/2006 18:10:00 6.6 0.9 9.1 4.6 6.6 0.9 9.5 4.6 3 6 1 305 32.2 4 41 20.7 01/27/2006 18:20:00 6.9 0.8 8.4 4.9 6.8 0.8 8.4 4.9 2 5 0 305 26.1 7.6 36.9 1.5 01/27/2006 18:30:00 6.8 0.8 8.8 4.9 6.9 0.8 8.8 4.6 355 5 355 305 34.9 3.2 41 22.8 01/27/2006 18:40:00 6.3 0.8 8.8 3.8 6.3 0.8 8.8 4.2 355 7 354 305 35.4 2.6 41.7 13.4 01/27/2006 18:50:00 7.7 1 9.9 5.3 7.8 1 10.3 5.3 354 5 354 305 35.5 3.7 41.7 24.3 01/27/2006 19:00:00 7.4 0.8 9.1 5.3 7.4 1 9.5 5.3 357 5 0 305 35 3.5 38.9 23.4 01/27/2006 19:10:00 6.9 0.8 9.5 4.9 6.9 0.9 9.9 4.9 348 6 347 305 36.6 3.7 41.3 25.2 01/27/2006 19:20:00 6.9 0.9 8.8 4.9 6.9 1 9.1 4.9 341 5 341 305 36.9 1.8 39.6 26.4 01/27/2006 19:30:00 6.5 0.8 9.5 4.6 6.6 0.9 9.1 4.6 340 6 338 305 37.1 4.4 44.5 24 01/27/2006 19:40:00 6.7 0.6 8.4 4.9 6.8 0.7 8.4 4.9 343 6 344 305 35.6 2.9 42 32 01/27/2006 19:50:00 6.8 0.7 8.4 5.3 6.7 0.7 8.4 4.9 343 9 337 305 33.8 0.9 36.6 31.4 01/27/2006 20:00:00 6.8 0.6 8.4 4.6 6.8 0.7 8.8 4.2 335 5 335 305 34.4 0.8 36.6 30.7 01/27/2006 20:10:00 6.1 0.7 7.6 4.2 6.1 0.7 8 4.6 337 5 332 305 33.9 0.9 35.3 29.5 01/27/2006 20:20:00 6.5 0.6 8 4.9 6.5 0.6 8 4.6 338 5 325 305 33.3 0.7 34.9 30.7 01/27/2006 20:30:00 6.4 0.7 8 4.2 6.5 0.7 8 4.2 339 5 333 305 31.5 2.2 35.3 24.6 01/27/2006 20:40:00 6.3 0.5 7.6 4.6 6.3 0.6 8 4.9 341 7 345 305 26.5 3.7 37.9 11.8 01/27/2006 20:50:00 6.2 0.6 7.6 4.2 6.3 0.7 7.6 3.8 341 5 336 305 32.4 3.8 36.6 13.4 01/27/2006 21:00:00 6.8 0.7 8.4 4.9 6.8 0.7 8.8 4.6 342 5 345 305 31 3.5 34.3 18.7 01/27/2006 21:10:00 7.1 0.8 9.1 4.9 7.1 0.7 8.8 5.3 1 6 342 305 27.5 4.5 34.3 17.3 01/27/2006 21:20:00 6.8 0.8 9.1 4.9 6.7 0.8 9.1 4.6 9 6 10 305 28.8 2.5 33 18.1 01/27/2006 21:30:00 6.6 0.7 8 4.9 6.4 0.8 8.4 4.2 6 6 4 305 26.7 4.7 32.6 0.3 01/27/2006 21:40:00 6.5 0.7 7.6 4.6 6.4 0.7 8 4.6 10 6 19 305 18.6 4 24 -0.4 01/27/2006 21:50:00 6.4 0.5 7.6 4.9 6.2 0.6 7.6 4.9 17 5 16 305 22.4 7 34.3 0.1 01/27/2006 22:00:00 6.7 0.6 8 4.9 6.6 0.6 8.4 4.9 16 4 17 305 20.9 7 32.3 -5.3 01/27/2006 22:10:00 7.2 0.6 8.8 5.7 7 0.6 8.4 5.3 18 5 13 305 22.2 6.2 30.7 -3.8 01/27/2006 22:20:00 6.9 0.8 9.1 4.9 6.8 0.8 8.8 4.9 15 6 21 305 22.6 8.3 37.6 1.3 01/27/2006 22:30:00 7.4 0.6 8.4 5.7 7.3 0.7 8.8 5.3 15 4 14 305 30.7 5.4 37.9 2.9 01/27/2006 22:40:00 7.5 0.6 8.8 5.7 7.4 0.6 8.8 5.7 13 4 11 305 25.6 5 32.6 7.7 01/27/2006 22:50:00 7.6 0.7 9.1 5.7 7.5 0.7 8.8 5.7 16 5 10 305 24.5 5.2 31.7 1 01/27/2006 23:00:00 7.4 0.7 9.1 5.7 7.3 0.8 9.1 5.7 17 4 21 305 23.2 6.4 31.4 -13.7 01/27/2006 23:10:00 8.2 0.8 9.9 6.1 8.1 0.8 9.9 5.7 16 6 12 305 25.2 4 30.4 11.8 01/27/2006 23:20:00 8.3 0.7 9.9 6.5 8.2 0.6 9.5 6.1 18 3 17 305 22 5.9 31.7 -4 01/27/2006 23:30:00 8.3 0.8 9.9 6.5 8.2 0.8 9.9 6.5 16 5 16 305 18.7 4.7 28.5 -3.8 01/27/2006 23:40:00 8.3 0.8 9.9 6.1 8.1 1 9.9 5.7 15 5 11 305 24.8 5 33 8.2 01/27/2006 23:50:00 8.2 0.8 9.9 6.1 8 0.7 9.5 6.1 16 4 20 305 21.6 3.5 27.6 7.9 01/28/2006 00:00:00 8 0.8 9.9 6.1 7.9 0.8 9.9 6.1 16 5 16 305 24.6 5.2 32.6 2.7 01/28/2006 00:10:00 8.8 0.6 10.3 6.8 8.6 0.7 10.3 6.5 15 4 9 305 32.1 4.7 43.4 14.8 01/28/2006 00:20:00 8.6 0.8 9.9 6.5 8.4 0.8 10.3 6.5 18 5 21 305 33.4 4.4 40.3 14.8 01/28/2006 00:30:00 8.2 0.7 9.5 6.1 8 0.7 9.5 5.3 16 5 12 305 34.8 5.4 42.4 14.5 01/28/2006 00:40:00 8.6 0.8 10.3 6.5 8.5 0.8 10.3 6.8 18 5 24 305 27 5.6 38.3 3.2 01/28/2006 00:50:00 8.5 0.8 10.3 6.5 8.4 0.8 11.1 6.1 18 5 24 305 31.6 4.2 35.6 4.2 01/28/2006 01:00:00 9.2 0.8 11.5 6.5 9 0.9 11.5 6.5 22 4 19 305 30.6 4.5 36.6 2.9 01/28/2006 01:10:00 9.3 0.7 10.7 7.6 9.1 0.7 11.1 7.2 22 4 22 305 34.6 4.4 42.7 3.4 01/28/2006 01:20:00 8.8 0.7 10.7 6.8 8.7 0.8 10.7 6.5 20 4 20 305 36.2 4.5 44.5 17.9 01/28/2006 01:30:00 8.5 0.7 9.9 6.5 8.4 0.7 9.9 6.1 16 4 18 305 36.6 4 44.8 22.8 01/28/2006 01:40:00 8.3 0.9 10.3 6.1 8.2 0.8 10.3 6.1 16 5 17 305 34.7 2.6 42 22.8 01/28/2006 01:50:00 8.9 0.8 10.3 6.5 8.7 0.8 10.3 6.8 17 4 13 305 30.1 1.4 32 19.6 01/28/2006 02:00:00 9 0.7 10.3 6.5 8.9 0.8 10.7 6.5 17 4 13 305 34.9 6.7 42.7 19.9 01/28/2006 02:10:00 8.6 1 10.3 6.5 8.5 1 10.3 6.1 18 5 17 305 41.5 2.6 45.5 28.5 01/28/2006 02:20:00 8.6 0.7 10.3 6.5 8.6 0.7 9.9 6.5 13 4 12 305 42.1 3.1 48.4 31.7 01/28/2006 02:30:00 8.4 0.5 9.9 6.8 8.3 0.6 9.5 6.8 14 4 18 305 37.2 4.2 43.4 24.9 01/28/2006 02:40:00 8.7 0.7 10.3 6.1 8.6 0.8 10.7 6.1 17 4 21 305 32.6 4.2 42.4 19 01/28/2006 02:50:00 9.1 0.6 10.7 6.8 8.9 0.8 10.7 6.5 20 4 14 305 34.4 4.4 39.3 20.4 01/28/2006 03:00:00 8.7 1 11.1 6.5 8.6 1 11.1 5.7 18 4 17 305 34.8 5.6 43.8 4.7 01/28/2006 03:10:00 8.3 0.7 9.9 6.1 8.2 0.8 9.9 6.1 16 5 9 305 26.3 5.9 37.9 8.7 01/28/2006 03:20:00 7.8 0.7 9.5 6.1 7.7 0.8 9.5 5.7 19 5 23 305 29.7 6.7 36.9 12.9 01/28/2006 03:30:00 6.9 0.9 8.8 4.9 6.8 1 8.8 4.9 16 5 18 305 35.3 4.5 43.8 14.8 01/28/2006 03:40:00 6.8 0.6 8.4 4.9 6.6 0.7 8 4.9 19 6 28 305 31.4 4 41.3 20.1 01/28/2006 03:50:00 6.7 0.6 8.8 5.3 6.6 0.6 8.4 4.9 14 5 26 305 27.9 1.5 31.7 10.5 01/28/2006 04:00:00 7 0.7 8.4 5.3 6.9 0.7 8.8 5.3 16 5 20 305 31.1 3.2 36.6 25.5 01/28/2006 04:10:00 7.3 0.6 8.4 5.7 7.2 0.6 8.8 5.7 15 4 17 305 33.5 1.5 35.9 25.2 01/28/2006 04:20:00 7.3 0.6 8.8 5.7 7.2 0.6 8.8 5.7 14 4 13 305 30.6 3.5 35.9 24.3 01/28/2006 04:30:00 7.2 0.7 8.8 5.3 7 0.7 8.4 4.6 12 4 12 305 33 2.6 36.6 22.8 01/28/2006 04:40:00 6.6 0.7 8.4 4.9 6.5 0.8 8.8 4.9 11 4 8 305 34.3 3.8 40 23.7 01/28/2006 04:50:00 6.5 0.6 8 4.6 6.4 0.7 8 4.6 11 5 7 305 36 4 42.7 23.4 01/28/2006 05:00:00 5.3 0.7 7.6 3.4 5.3 0.8 7.6 3.4 11 6 19 305 37.6 4.4 43.8 26.1 01/28/2006 05:10:00 6 0.4 7.2 4.9 5.9 0.5 7.2 4.9 19 4 18 305 39.4 3.2 42.7 27 01/28/2006 05:20:00 5.8 0.6 7.2 4.2 5.6 0.6 7.2 4.2 17 4 16 305 33 3.8 43.4 22.2 01/28/2006 05:30:00 5 0.5 6.5 3.8 4.8 0.6 6.1 3 7 11 4 305 32.7 2.8 37.2 17.9 01/28/2006 05:40:00 4.8 0.5 6.1 3.8 4.7 0.6 6.1 3.4 347 4 355 305 32.9 5 40.6 25.2 01/28/2006 05:50:00 4.6 0.5 5.7 3.4 4.4 0.5 5.7 2.6 354 6 350 305 39 0.7 40.3 35.9 01/28/2006 06:00:00 5.4 1 7.2 3 5.2 0.9 7.2 3.4 356 5 358 305 35.7 3.4 40 28.2 01/28/2006 06:10:00 5.2 0.6 6.8 3.8 5.2 0.6 6.8 3.8 351 8 353 305 32.6 3.5 42 28.8 01/28/2006 06:20:00 5.5 0.4 6.5 4.2 5.3 0.4 6.5 4.2 339 4 343 305 38.5 3.7 41.3 29.8 01/28/2006 06:30:00 5.3 0.4 6.5 4.6 5.1 0.4 6.5 4.2 340 4 344 305 37.2 4.2 46.3 29.8 01/28/2006 06:40:00 5.1 0.4 5.7 4.2 5 0.4 6.1 4.2 345 4 344 305 38.6 2.8 41.3 30.1 01/28/2006 06:50:00 4.2 0.6 5.7 3 4 0.6 5.7 2.6 344 6 345 305 39.3 1 42.7 32.6 01/28/2006 07:00:00 3.8 0.5 4.9 2.3 3.6 0.6 4.9 2.3 344 5 349 305 37.1 3.7 40.6 29.2 01/28/2006 07:10:00 3.1 0.4 4.2 2.3 2.9 0.4 4.2 1.9 332 8 322 305 30.8 1 38.6 28.2 01/28/2006 07:20:00 3.8 0.4 4.6 2.6 3.5 0.4 4.6 2.6 327 4 328 305 32.5 3.4 45.5 29.2 01/28/2006 07:30:00 3.3 0.4 4.2 2.3 3 0.3 3.8 1.9 330 5 330 305 40.7 1.9 46.6 30.7 01/28/2006 07:40:00 3.2 0.3 3.8 2.6 3.1 0.3 3.8 2.3 349 6 337 305 40.2 2.2 42 30.7 01/28/2006 07:50:00 4.1 0.4 4.9 3 4 0.4 4.9 2.6 353 5 351 305 37.9 6.2 48.8 27 01/28/2006 08:00:00 4.8 0.5 5.7 3 4.6 0.5 5.7 3 347 3 346 305 36.2 5.2 47.3 24.9 01/28/2006 08:10:00 3.9 0.8 5.3 2.3 3.7 0.8 5.3 2.3 345 5 348 305 42.2 5 49.9 24.6 01/28/2006 08:20:00 3.6 0.3 4.2 2.6 3.2 0.4 4.2 2.3 334 4 333 305 44.2 3.5 51.4 25.8 01/28/2006 08:30:00 3.3 0.4 4.6 2.6 3 0.4 4.6 2.3 337 5 332 305 40.1 5.2 45.9 0.1 01/28/2006 08:40:00 2.9 0.4 3.8 2.3 2.4 0.3 3.4 1.9 334 4 330 305 38 4.2 44.8 20.4 01/28/2006 08:50:00 2.8 0.3 3.8 2.3 2.2 0.3 3 1.5 334 6 334 305 41.8 3.5 48.4 26.4 01/28/2006 09:00:00 3.1 0.3 3.8 2.3 2.4 0.4 3.4 1.5 326 6 323 305 40.1 2.9 46.6 29.8 01/28/2006 09:10:00 1.8 0.7 3.8 0.4 1.1 0.6 2.6 0.4 347 15 333 305 35.7 3.7 45.2 23.4 01/28/2006 09:20:00 3.3 1 5.3 0.7 2.8 1 4.9 0.4 349 11 345 305 45.5 6.4 52.9 23.1 01/28/2006 09:30:00 4.6 0.6 6.5 3.4 4.3 0.6 6.5 3 353 6 352 305 48.2 3.7 52.9 36.2 01/28/2006 09:40:00 5.1 0.6 6.5 3.8 4.9 0.6 6.5 3.4 353 5 349 305 38.8 3.7 45.2 23.7 01/28/2006 09:50:00 4 0.5 5.3 2.6 3.8 0.4 4.9 2.6 353 5 342 305 40.5 3.2 48.4 22.2 01/28/2006 10:00:00 4.6 0.6 6.1 3.4 4.4 0.6 6.1 3 353 5 353 305 41 5 51 26.7 01/28/2006 10:10:00 4 0.5 5.3 3 3.8 0.5 5.3 2.3 354 6 349 305 29 5.2 41.3 20.1 01/28/2006 10:20:00 4.7 0.6 6.5 3 4.4 0.5 5.7 3 356 5 356 305 36.7 5.9 49.5 4.9 01/28/2006 10:30:00 4.2 0.5 5.3 3 3.9 0.5 5.3 2.6 355 5 358 305 34.5 2.7 43.8 23.7 01/28/2006 10:40:00 4.2 0.4 5.7 3 3.9 0.4 5.3 2.6 357 5 3 305 37.2 3.5 44.5 21.6 01/28/2006 10:50:00 4.2 0.5 5.7 3 3.9 0.5 5.3 2.6 358 4 358 305 35.2 4 41.7 13.4 01/28/2006 11:00:00 4.3 0.4 5.3 3.4 4 0.5 4.9 2.6 357 6 2 305 26 6.4 37.9 16.5 01/28/2006 11:10:00 4.1 0.4 4.9 3 3.8 0.4 5.3 2.6 356 5 0 305 29.1 7 38.3 17.3 01/28/2006 11:20:00 5 0.8 6.8 3 4.7 0.7 6.8 3 359 5 5 305 37.7 4.4 44.5 23.1 01/28/2006 11:30:00 5.6 0.6 7.2 4.2 5.3 0.6 7.2 4.2 0 5 0 305 32.6 5.2 40.6 16.2 01/28/2006 11:40:00 7.3 1.1 10.3 4.9 7.2 1.1 10.3 4.9 10 5 12 305 31.3 4 35.9 17 01/28/2006 11:50:00 6.7 0.9 8.8 4.6 6.6 0.9 8.8 4.2 3 5 359 305 27.8 4.4 34.3 10.8 01/28/2006 12:00:00 7.1 0.9 9.1 4.9 6.9 0.9 8.8 4.6 1 5 3 305 25.7 5.2 34.3 11.8 01/28/2006 12:10:00 5.9 0.7 7.6 4.2 5.6 0.7 7.6 4.2 1 4 5 305 32.2 7 42.4 14.5 01/28/2006 12:20:00 5.8 0.5 7.6 4.6 5.5 0.6 7.2 3.8 0 4 1 305 34.6 5.4 43.4 16.5 01/28/2006 12:30:00 5.5 0.5 6.8 4.2 5.2 0.5 6.5 4.2 359 4 0 305 34.3 5.6 43.4 4.4 01/28/2006 12:40:00 6.3 1.2 9.1 4.2 6.1 1.2 8.8 3.8 357 6 347 305 26.1 8.3 34.6 -1.3 01/28/2006 12:50:00 7.2 0.7 8.8 5.3 7.2 0.7 9.1 5.3 356 5 350 305 28.5 8 40.3 -2 01/28/2006 13:00:00 6 0.7 7.6 4.2 5.9 0.8 8.4 4.2 352 7 340 305 34.3 5.4 42.4 14.8 01/28/2006 13:10:00 7.2 1 10.3 5.3 7.2 1 10.3 5.3 348 5 345 305 33.4 2.3 37.2 23.7 01/28/2006 13:20:00 7 0.7 8.8 5.3 6.9 0.7 8.8 5.3 348 4 344 305 33.8 1.8 37.6 27.6 01/28/2006 13:30:00 5.8 0.7 7.6 4.6 5.7 0.7 7.6 3.8 347 6 358 305 33.9 1.3 36.6 21.9 01/28/2006 13:40:00 6.8 0.8 8.8 4.9 6.7 0.9 8.4 4.6 354 5 359 305 27.7 4.2 33.6 11.8 01/28/2006 13:50:00 6.6 0.7 8.8 4.9 6.5 0.6 8 4.9 355 5 354 305 27 5.4 33.3 11.3 01/28/2006 14:00:00 6.9 0.7 9.1 5.3 6.7 0.8 8.8 4.9 355 5 349 305 27 4.4 32.3 -13.9 01/28/2006 14:10:00 6.6 1 8.8 3.8 6.6 1 9.1 4.6 354 5 355 305 24.7 3.5 29.8 14.8 01/28/2006 14:20:00 6.8 0.7 8.4 4.6 6.6 0.7 8.4 4.6 354 5 350 305 12.3 3.1 21.6 7.7 01/28/2006 14:30:00 7.7 1 9.9 5.7 7.6 1 9.9 5.3 348 6 352 305 17.5 1.1 19.6 13.7 01/28/2006 14:40:00 8.1 1 10.3 5.3 7.9 1 10.3 5.3 351 6 350 305 18.5 0.5 19.3 16.5 01/28/2006 14:50:00 8.3 1 10.3 5.3 8.1 1 10.7 5.7 353 5 352 305 21.9 4 30.4 15.9 01/28/2006 15:00:00 7.7 0.8 9.5 5.7 7.6 0.8 9.5 5.7 352 6 353 305 31.4 3.8 37.9 19.6 01/28/2006 15:10:00 7.3 1 9.9 4.9 7.1 1 9.9 4.6 351 6 356 305 26.9 1.9 30.4 19 01/28/2006 15:20:00 7.2 0.9 9.1 4.9 7.1 0.9 9.1 4.9 353 6 353 305 24.5 2.4 27.6 15.1 01/28/2006 15:30:00 7.3 1.1 10.3 4.9 7.1 1.1 10.3 4.6 354 6 356 305 13.2 3.2 27.6 9.7 01/28/2006 15:40:00 9.1 1 11.1 6.5 8.9 1.1 11.5 6.5 354 5 354 305 20.6 7 33.3 11.3 01/28/2006 15:50:00 9.4 1 11.8 6.8 9.3 1.1 11.8 6.5 356 5 1 305 22.5 5 28.5 12.9 01/28/2006 16:00:00 9.5 1.2 11.8 6.5 9.3 1.2 12.6 6.5 355 5 356 305 25.3 2.4 27.6 15.6 01/28/2006 16:10:00 8.8 1.1 11.8 6.1 8.7 1.2 11.8 6.5 354 6 347 305 23.5 3.4 27.6 14.3 01/28/2006 16:20:00 7.6 1.1 11.8 5.7 7.5 1 12.2 5.3 353 6 357 305 21.7 3.2 26.1 14 01/28/2006 16:30:00 10.5 1.1 12.6 7.2 10.4 1.1 13 7.6 357 5 1 305 25.9 1.8 29.2 14.5 01/28/2006 16:40:00 10.9 1.2 14.1 7.2 10.7 1.3 13.7 7.6 2 5 354 305 25.2 1.4 29.2 20.7 01/28/2006 16:50:00 12.5 1.3 15.6 8.4 12.4 1.3 15.3 9.1 2 5 0 305 25.3 1.4 28.8 18.7 01/28/2006 17:00:00 11.5 1.3 14.5 8 11.3 1.4 14.5 8 5 6 13 305 25.6 1.5 29.8 19 01/28/2006 17:10:00 11.7 1.4 14.1 7.6 11.6 1.4 14.5 7.2 4 5 4 305 24.3 2 31.7 14.8 01/28/2006 17:20:00 11.7 1.3 14.5 7.6 11.7 1.3 14.9 8.8 359 5 0 305 25.8 2.4 30.4 20.4 01/28/2006 17:30:00 11.7 1.5 14.9 7.2 11.6 1.6 14.5 6.8 359 6 0 305 27.7 2.1 31 16.7 01/28/2006 17:40:00 11.4 1.1 13.7 8.4 11.2 1.1 13.7 8.4 357 5 0 305 27.8 2.1 30.7 17 01/28/2006 17:50:00 11.5 0.9 13.7 9.1 11.3 1 13.7 8.8 0 5 358 305 22 3.8 29.2 15.1 01/28/2006 18:00:00 10.3 1.3 13.7 7.2 10.2 1.4 13.7 6.8 1 6 358 305 21.7 5 30.1 14.8 01/28/2006 18:10:00 10.8 1.3 13.7 7.2 10.5 1.4 13.7 6.8 1 6 357 305 30.5 3.1 34.6 18.7 01/28/2006 18:20:00 12.4 1.7 15.6 8.4 12.1 1.6 16.4 8.8 2 5 357 305 31.4 2 36.2 18.4 01/28/2006 18:30:00 11.6 1.2 14.9 8.8 11.5 1.3 14.5 8 1 5 1 305 32.2 1.8 36.6 22.8 01/28/2006 18:40:00 11.3 1.2 14.9 8 11.2 1.1 14.9 8.4 5 5 10 305 33.9 2.8 39.3 22.5 01/28/2006 18:50:00 11.4 1.2 14.5 8 11.2 1.3 15.3 7.6 4 6 5 305 33.3 1.9 38.6 22.2 01/28/2006 19:00:00 12 1.5 15.3 8.4 11.8 1.6 15.3 8 5 5 3 305 34.9 2.6 40 24.9 01/28/2006 19:10:00 11.8 1.3 14.9 8.4 11.6 1.3 14.5 8.8 5 6 8 305 35.7 1.9 43.4 29.2 01/28/2006 19:20:00 11.4 1.5 14.5 8 11.2 1.5 14.5 8 6 6 358 305 37.3 1.8 40.6 24.3 01/28/2006 19:30:00 11.7 1.1 14.1 8 11.4 1.1 14.1 8.4 8 5 10 305 37 1.8 39.3 24.6 01/28/2006 19:40:00 11.5 1.3 14.5 8.4 11.3 1.3 14.5 8 6 5 0 305 36.2 1.6 40.3 24.3 01/28/2006 19:50:00 12.9 1.5 16.1 8.8 12.7 1.6 16.1 8.8 6 5 358 305 33.6 4.2 39.6 21.3 01/28/2006 20:00:00 13.3 1.3 16.4 7.2 13.2 1.3 16.4 8.8 6 4 8 305 33.4 2.9 38.9 24.9 01/28/2006 20:10:00 12.5 1.2 15.3 8.8 12.4 1.3 15.3 8 7 5 3 305 28.9 2 33.3 23.7 01/28/2006 20:20:00 11.8 1.4 15.3 8.4 11.7 1.3 14.9 8.4 1 6 358 305 28.1 2.4 31.7 19 01/28/2006 20:30:00 10.6 1.4 14.5 7.6 10.6 1.4 14.1 7.6 6 6 4 305 21.7 2.4 27.3 16.7 01/28/2006 20:40:00 11.6 1.3 14.9 8.4 11.4 1.5 15.3 8 7 5 10 305 23.5 2.3 28.2 19.6 01/28/2006 20:50:00 12.6 1.5 16.4 9.1 12.5 1.5 16.1 8.8 7 5 3 305 26.5 1.6 29.8 21.3 01/28/2006 21:00:00 12.5 1.6 16.1 8 12.3 1.6 15.6 8.4 6 5 10 305 27.4 1.8 29.8 21.3 01/28/2006 21:10:00 11.9 1.4 14.9 8 11.7 1.4 14.5 8.4 5 6 11 305 28.2 1.8 32 21.9 01/28/2006 21:20:00 13 1.2 16.1 8.8 12.7 1.2 15.6 8.4 5 5 9 305 34.5 3.1 39.6 26.7 01/28/2006 21:30:00 12.9 1.5 16.8 9.1 12.9 1.5 16.4 8.8 5 6 5 305 36 2.3 41 25.2 01/28/2006 21:40:00 13.3 1.6 17.2 9.5 13 1.7 16.8 9.5 4 5 9 305 34.6 3.7 42 24.3 01/28/2006 21:50:00 13.7 1.3 17.2 10.3 13.6 1.3 16.8 9.9 6 5 4 305 30.4 2.4 35.3 22.2 01/28/2006 22:00:00 14.5 1.3 17.6 11.1 14.2 1.3 17.6 10.7 4 5 2 305 31.8 3.1 39.3 24.3 01/28/2006 22:10:00 13.1 1.7 16.8 8.8 12.9 1.7 16.8 8.4 4 6 13 305 37.7 2.3 43.8 27.9 01/28/2006 22:20:00 13.1 1.6 17.6 9.9 12.9 1.5 16.8 9.5 5 6 10 305 40.6 5.2 51 27.3 01/28/2006 22:30:00 14.2 1.5 18.7 10.3 13.9 1.6 17.9 10.3 4 5 4 305 43.5 3.7 49.9 27.6 01/28/2006 22:40:00 14.2 1.4 17.9 9.9 14 1.4 17.2 10.7 6 5 3 305 38.2 3.5 49.5 26.7 01/28/2006 22:50:00 14 1.5 16.8 10.3 13.9 1.4 17.2 10.7 7 5 7 305 35.3 2.4 40.6 26.4 01/28/2006 23:00:00 13.6 1.3 17.6 10.7 13.5 1.4 17.2 9.9 8 5 9 305 40 12.9 52.1 19 01/28/2006 23:10:00 13.9 1.7 17.9 10.3 13.6 1.6 17.2 9.9 10 6 7 305 30.8 4.2 36.9 19.3 01/28/2006 23:20:00 15.1 1.3 17.9 11.8 14.8 1.5 18.3 11.1 12 5 13 305 36 2.7 40 26.4 01/28/2006 23:30:00 14.9 1.8 19.1 10.7 14.7 1.9 19.5 9.5 11 5 8 305 36.8 1.5 39.6 30.7 01/28/2006 23:40:00 14 1.6 17.6 10.3 13.9 1.6 17.2 9.9 12 5 17 305 37.2 1.4 39.6 28.5 01/28/2006 23:50:00 13.6 2.1 17.9 9.5 13.4 1.9 17.6 9.5 15 6 13 305 37.1 1.6 40 30.1 01/29/2006 00:00:00 14.4 1.7 18.3 10.3 14.1 1.7 17.9 9.5 16 5 19 305 36.3 1.5 38.9 27 01/29/2006 00:10:00 14.1 1.4 17.6 9.9 14 1.5 17.6 9.1 15 5 18 305 34.1 2.6 38.6 26.7 01/29/2006 00:20:00 14.2 1.6 18.3 10.3 14.1 1.6 17.9 10.3 16 5 13 305 33 1.5 40.3 27.9 01/29/2006 00:30:00 13.1 1.7 17.6 9.1 12.8 1.7 17.2 9.5 13 5 9 305 37.4 2.1 40.3 29.8 01/29/2006 00:40:00 13.9 1.3 16.4 9.5 13.7 1.5 16.8 9.1 11 5 15 305 36.6 1 40 32.6 01/29/2006 00:50:00 11.8 1.6 16.1 8.4 11.6 1.6 15.6 8 15 6 18 305 35 1.8 37.6 27.6 01/29/2006 01:00:00 12.5 1.6 15.6 8.8 12.3 1.6 16.4 8.4 13 5 20 305 35.4 1.5 37.9 28.2 01/29/2006 01:10:00 13.8 1.5 16.4 9.1 13.6 1.4 16.8 9.1 11 5 13 305 35.3 1.9 38.6 27.3 01/29/2006 01:20:00 13.6 1.3 16.4 10.7 13.5 1.3 16.4 10.3 12 5 15 305 33.6 2.1 36.9 26.1 01/29/2006 01:30:00 14.3 1.3 17.2 9.5 14 1.3 16.8 9.9 11 5 7 305 33.2 2.6 37.9 24.9 01/29/2006 01:40:00 13.8 1.5 16.8 9.9 13.6 1.5 16.8 9.1 10 6 7 305 33.9 2.6 37.9 26.4 01/29/2006 01:50:00 13.5 1.6 17.6 9.9 13.1 1.7 16.8 8.8 12 5 11 305 31.9 2.7 36.6 25.2 01/29/2006 02:00:00 14.5 1.5 17.6 11.1 14.3 1.5 17.6 10.7 12 5 7 305 27.1 1.2 30.4 21 01/29/2006 02:10:00 14.4 1.7 18.3 10.7 14 1.7 18.3 9.5 15 5 13 305 26.5 1.2 30.1 21 01/29/2006 02:20:00 14.3 1.3 16.8 11.1 14 1.3 17.2 10.3 14 5 15 305 29 2.1 33.3 23.4 01/29/2006 02:30:00 13.8 1.3 17.6 9.9 13.5 1.3 16.8 9.9 15 5 16 305 30.5 1 32.6 24.6 01/29/2006 02:40:00 14.5 1.5 17.6 11.1 14.1 1.6 17.6 10.3 12 5 15 305 31.2 1 33.3 24.9 01/29/2006 02:50:00 15 1.4 17.9 11.5 14.5 1.4 17.9 11.1 11 5 15 305 31 1.4 33.3 24.6 01/29/2006 03:00:00 14.9 1.3 18.7 11.8 14.5 1.3 17.6 11.1 11 5 18 305 35.4 3.7 40.3 25.8 01/29/2006 03:10:00 14.2 1.3 17.6 10.7 13.9 1.3 17.2 9.9 9 6 6 305 37.6 1.6 40 26.7 01/29/2006 03:20:00 14.2 1.5 17.9 9.9 13.9 1.5 17.6 10.3 11 6 16 305 34 2.9 40.3 26.4 01/29/2006 03:30:00 13.9 1.7 18.3 10.3 13.5 1.7 17.9 9.1 12 5 13 305 38.5 1.4 40.6 32.3 01/29/2006 03:40:00 13 1.5 16.8 8.8 12.8 1.5 16.4 8.8 11 5 11 305 38.1 1.4 40.3 30.7 01/29/2006 03:50:00 13.3 1.8 17.2 9.1 13.1 1.8 16.8 9.1 13 5 7 305 38 1.6 40.3 31.4 01/29/2006 04:00:00 14 1.6 17.2 9.5 13.7 1.5 16.8 9.1 12 5 19 305 35.3 2.5 39.6 27 01/29/2006 04:10:00 12.4 1.5 16.1 8.4 12 1.5 16.4 8.8 16 6 8 305 33.8 1.3 35.9 27.3 01/29/2006 04:20:00 11.8 1.2 14.1 8.4 11.5 1.3 14.1 8.4 17 5 20 305 33.9 1.9 38.9 27 01/29/2006 04:30:00 12 1.5 15.3 8.4 11.8 1.5 15.3 8 9 6 5 305 35.9 1.7 38.9 27.6 01/29/2006 04:40:00 12.3 1.2 15.6 8.4 12.1 1.3 15.6 8.8 9 5 15 305 36.7 0.9 38.9 32 01/29/2006 04:50:00 12.6 1.2 16.1 9.5 12.5 1.2 16.1 9.1 10 5 4 305 36.6 1.6 42 30.7 01/29/2006 05:00:00 12.9 1.3 15.6 8.8 12.5 1.3 15.6 8.8 16 4 18 305 38.7 2.3 42.4 31.4 01/29/2006 05:10:00 11.7 1.1 14.1 9.1 11.4 1.1 14.9 8.8 12 6 15 305 37.8 2.5 43.1 31 01/29/2006 05:20:00 12.2 1.4 16.1 9.1 12 1.5 15.6 8.8 10 5 9 305 38 2.7 42.7 26.4 01/29/2006 05:30:00 13.5 1.3 16.4 9.9 13.3 1.3 16.4 10.3 10 5 12 305 37.5 2.9 42 27 01/29/2006 05:40:00 12.3 1.3 15.3 8.8 11.9 1.4 15.3 8.4 7 5 8 305 35.7 3.4 40.6 27.6 01/29/2006 05:50:00 12.2 1.1 15.3 9.1 11.9 1.1 15.3 9.1 9 6 8 305 36.2 2.9 41 27.3 01/29/2006 06:00:00 12.9 1.3 16.1 9.1 12.7 1.3 16.1 9.1 6 6 5 305 36.7 2.9 41.3 27.3 01/29/2006 06:10:00 12.1 1.2 14.9 7.6 11.8 1.2 14.9 8.4 8 5 9 305 38.7 3.7 44.8 27.6 01/29/2006 06:20:00 11.9 1.5 14.9 8 11.7 1.5 14.9 7.6 7 6 8 305 35.7 3.8 44.8 26.7 01/29/2006 06:30:00 12.6 1.3 15.3 9.1 12.4 1.3 15.6 8.8 7 5 7 305 38.3 3.1 43.4 30.1 01/29/2006 06:40:00 11.6 1.6 14.9 8 11.4 1.5 14.9 8 6 6 4 305 38.2 3.1 43.8 29.8 01/29/2006 06:50:00 11.8 1.4 15.3 7.6 11.7 1.4 15.6 7.6 2 6 357 305 39.3 2.6 42.7 31 01/29/2006 07:00:00 11.8 1.4 14.9 8.8 11.8 1.5 15.3 7.6 6 6 11 305 41.1 5.6 51.8 30.1 01/29/2006 07:10:00 11.7 1.2 14.5 8.8 11.5 1.3 14.5 8.8 9 6 4 305 45 4.7 52.5 29.5 01/29/2006 07:20:00 12.6 1 14.9 9.5 12.4 1.1 15.3 9.1 8 5 6 305 41.7 4 47.7 29.5 01/29/2006 07:30:00 12.5 1.4 15.6 9.1 12.3 1.5 15.3 8.8 9 5 13 305 41.5 4.2 47.7 27.6 01/29/2006 07:40:00 12.3 1.5 15.3 8.4 12.1 1.5 15.3 8.4 8 5 13 305 41.9 4 52.1 31 01/29/2006 07:50:00 12 1 14.9 9.5 11.9 1.1 14.9 8.8 9 6 10 305 46.1 3.4 52.9 34.3 01/29/2006 08:00:00 10.9 1.4 13.7 7.6 10.6 1.5 13.7 7.2 4 6 12 305 46.4 4.5 52.9 28.8 01/29/2006 08:10:00 10.4 1 12.6 8 10.1 1 12.6 7.2 9 7 12 305 46.1 4.4 51 30.4 01/29/2006 08:20:00 11.6 1.4 14.9 7.6 11.4 1.5 14.9 7.2 13 5 16 305 41.8 5.6 49.5 29.8 01/29/2006 08:30:00 10.8 1.2 13.3 7.2 10.6 1.2 13.7 7.6 12 5 7 305 42.4 4.5 48.8 28.5 01/29/2006 08:40:00 10.9 1.1 13.3 7.6 10.8 1.2 13.3 7.6 10 5 14 305 40 3.8 45.5 28.2 01/29/2006 08:50:00 10.6 1.1 13.3 7.2 10.3 1.1 13.3 6.8 9 6 4 305 40.3 2.9 46.6 32.6 01/29/2006 09:00:00 11 1.2 13.7 8 10.9 1.2 13.3 8 8 5 7 305 43.9 2.8 49.9 31.4 01/29/2006 09:10:00 9.7 1.1 12.2 6.8 9.6 1.2 12.6 6.8 11 6 11 305 43.1 3.4 49.2 34.6 01/29/2006 09:20:00 11.2 1.2 14.1 8 10.9 1.3 13.7 7.6 14 6 4 305 39.9 3.8 48.1 31.4 01/29/2006 09:30:00 10.7 1.3 13.7 7.6 10.5 1.3 13 7.2 14 6 23 305 39 2.2 44.8 27 01/29/2006 09:40:00 10.6 1.2 14.1 7.6 10.4 1.2 14.5 7.6 10 6 9 305 40 3.2 44.5 30.7 01/29/2006 09:50:00 10.8 1.2 13.7 8 10.7 1.2 14.1 8 8 6 11 305 41.3 5.2 49.5 31.4 01/29/2006 10:00:00 12.2 1.5 16.4 8 12 1.5 16.1 8.4 10 5 8 305 44.8 4 50.6 28.8 01/29/2006 10:10:00 11.6 1.3 15.3 7.6 11.5 1.3 14.9 7.2 17 7 16 305 44.1 4.7 51.8 22.2 01/29/2006 10:20:00 10.5 1.3 13.7 7.2 10.2 1.2 13 7.2 17 6 14 305 41.1 4.7 49.2 29.8 01/29/2006 10:30:00 12.2 1.4 15.3 8.8 12 1.4 15.6 8.8 19 6 22 305 40.9 4.7 47.7 32.3 01/29/2006 10:40:00 12.5 1.5 16.4 9.1 12.2 1.5 16.1 8 20 6 14 305 39.9 4.2 45.2 27.6 01/29/2006 10:50:00 13.9 1.8 17.9 9.1 13.6 1.7 18.3 9.5 22 6 9 305 40.3 4.2 45.9 30.7 01/29/2006 11:00:00 14.5 1.5 17.9 10.3 14.2 1.5 17.6 9.9 20 5 17 305 35.7 4 44.8 30.4 01/29/2006 11:10:00 14.4 1.5 17.9 10.7 14.1 1.5 17.9 10.3 24 6 23 305 34 1.5 37.9 31.7 01/29/2006 11:20:00 14.9 1.4 18.7 11.5 14.4 1.5 18.3 11.1 23 6 23 305 42.5 1.9 45.9 32.3 01/29/2006 11:30:00 14.4 1.8 17.9 9.5 14 1.8 17.6 9.5 23 7 40 305 42.7 1.2 45.5 37.6 01/29/2006 11:40:00 14.3 2.2 18.3 9.5 14 2.1 17.9 9.5 28 7 25 305 41 1.4 43.4 34.3 01/29/2006 11:50:00 14.8 2.2 19.1 10.3 14.3 2.2 18.7 9.9 27 6 18 305 42.2 1.4 44.8 36.6 01/29/2006 12:00:00 14.8 1.5 19.1 11.1 14.3 1.5 18.3 11.1 31 5 28 305 41.2 4 51 33 01/29/2006 12:10:00 14.2 2.5 20.6 9.1 13.8 2.4 19.9 8.8 29 6 26 305 38.8 3.8 44.5 31.7 01/29/2006 12:20:00 14.7 1.7 18.7 10.7 14.3 1.7 18.3 10.3 32 6 27 305 37.1 2.4 44.5 33 01/29/2006 12:30:00 15.8 1.9 20.2 10.3 15.4 1.8 19.5 10.7 29 6 29 305 37.8 1.8 43.1 29.8 01/29/2006 12:40:00 16.1 1.4 19.9 11.8 15.6 1.5 20.2 11.8 31 5 35 305 38.3 2.8 42.4 28.8 01/29/2006 12:50:00 16.3 1.7 20.2 12.2 15.9 1.7 20.2 11.1 27 6 25 305 41.8 3.7 51 29.5 01/29/2006 13:00:00 15.4 1.6 18.7 11.1 15 1.5 18.7 11.1 28 7 40 305 36.3 3.5 45.9 29.2 01/29/2006 13:10:00 14.7 2.1 19.1 9.9 14.3 2 19.1 9.5 26 7 25 305 34.4 4.4 40.6 22.2 01/29/2006 13:20:00 14.7 1.7 18.3 10.3 14.3 1.8 18.3 9.9 25 6 17 305 11.8 15.3 31.7 -14.3 01/29/2006 13:30:00 13.4 1.5 16.8 9.5 13 1.6 16.4 9.5 25 7 24 305 31.8 4.5 38.9 19.6 01/29/2006 13:40:00 14.7 1.3 17.9 11.1 14.2 1.3 17.9 11.1 27 6 27 305 35.8 3.5 41.7 27.9 01/29/2006 13:50:00 14.2 1.6 17.9 9.9 13.8 1.5 18.3 10.3 32 7 23 305 35.3 4.2 42 24.3 01/29/2006 14:00:00 14.5 1.7 17.9 10.3 14.1 1.5 17.2 10.7 30 5 30 305 32.8 4 39.3 18.4 01/29/2006 14:10:00 14.4 1.1 16.8 11.1 14 1.2 17.2 10.3 30 5 28 305 31.8 4.4 38.9 21.9 01/29/2006 14:20:00 13.9 1.3 17.2 10.7 13.6 1.4 17.2 10.3 26 6 36 305 25.7 2.8 33.9 17.3 01/29/2006 14:30:00 14.1 1.5 17.2 9.9 13.7 1.4 17.2 9.9 29 6 25 305 23.6 3.1 29.2 15.3 01/29/2006 14:40:00 15.7 2.5 20.2 9.5 15.2 2.5 20.6 9.1 23 6 25 305 25.7 5.9 35.3 7.4 01/29/2006 14:50:00 15.9 1.9 20.2 9.9 15.4 1.9 19.9 10.3 26 6 24 305 28.9 2.9 35.3 20.4 01/29/2006 15:00:00 16.2 1.7 19.9 12.2 15.7 1.7 20.2 11.8 27 6 25 305 25.9 5.4 34.6 13.2 01/29/2006 15:10:00 13.6 1.7 17.2 9.5 13.4 1.6 16.8 9.1 26 6 29 305 22.2 3.7 33.6 12.1 01/29/2006 15:20:00 12.9 1.7 16.4 9.1 12.5 1.7 16.1 8.4 23 6 25 305 15.8 2.3 19.6 8.2 01/29/2006 15:30:00 13.7 1.5 17.6 10.3 13.4 1.5 17.2 9.5 24 6 20 305 12.6 3.8 21.6 5.2 01/29/2006 15:40:00 14 1.6 17.6 9.9 13.7 1.5 18.7 10.3 18 6 19 305 15.9 2.3 24 10.8 01/29/2006 15:50:00 14.6 1.7 19.1 10.7 14.3 1.7 18.3 10.3 19 5 18 305 14.5 2.4 20.4 10.2 01/29/2006 16:00:00 17 1.7 20.6 12.6 16.5 1.5 19.9 11.5 25 6 29 305 16.7 9.5 31.7 -2.4 01/29/2006 16:10:00 16.3 1.7 19.9 12.2 15.9 1.7 19.5 11.1 22 6 33 305 31.2 2.2 36.6 18.7 01/29/2006 16:20:00 16.4 1.8 20.2 11.8 16 1.8 20.2 11.8 26 6 19 305 33.5 2.1 38.6 24 01/29/2006 16:30:00 16.8 2 21 11.8 16.5 1.9 21 11.1 25 7 32 305 34.3 2.1 38.3 26.7 01/29/2006 16:40:00 16.4 2.4 21.8 10.3 15.9 2.3 21.4 11.1 30 7 20 305 31.8 2.1 36.2 19.9 01/29/2006 16:50:00 18 1.9 21.8 13.3 17.4 1.9 21.8 13 31 6 24 305 33.4 2.1 37.6 27.3 01/29/2006 17:00:00 15.9 1.8 20.2 11.5 15.6 1.9 20.2 11.1 30 6 30 305 33.9 2.3 38.9 26.4 01/29/2006 17:10:00 16.2 1.6 19.5 12.2 15.7 1.5 19.5 11.5 28 6 31 305 34.3 1.6 37.6 29.5 01/29/2006 17:20:00 16.5 1.5 19.5 12.6 15.9 1.5 19.1 12.2 28 5 35 305 30.9 3.1 37.6 23.1 01/29/2006 17:30:00 15.3 2 19.9 10.7 15 2 19.9 11.1 25 6 18 305 34.2 2.2 39.3 23.4 01/29/2006 17:40:00 16.1 1.7 19.5 10.7 15.7 1.7 19.1 11.1 25 5 29 305 34.8 2.1 39.6 27.6 01/29/2006 17:50:00 15.7 1.6 21 11.8 15.6 1.6 19.9 11.1 23 5 19 305 35.5 2.1 39.6 28.2 01/29/2006 18:00:00 16.4 1.5 20.2 11.8 16.1 1.5 19.5 11.5 18 5 16 305 34.7 1.8 39.6 27.6 01/29/2006 18:10:00 17.1 1.5 20.6 12.6 16.7 1.4 19.5 13.3 17 4 19 305 35.2 1.9 39.6 27.6 01/29/2006 18:20:00 16.5 1.7 21 12.2 16 1.7 21 11.1 22 5 19 305 35.3 2.4 40 28.2 01/29/2006 18:30:00 15.6 2.2 20.6 10.7 15.5 2.3 20.6 10.3 21 5 10 305 34 2.2 39.3 26.7 01/29/2006 18:40:00 15 1.6 19.5 10.7 14.7 1.6 19.5 11.5 24 6 30 305 38 5 48.4 27.3 01/29/2006 18:50:00 15.2 1.5 18.7 11.8 15 1.5 17.9 11.1 27 5 29 305 43.3 2.1 48.4 33.9 01/29/2006 19:00:00 16 1.6 18.3 11.1 15.6 1.6 18.7 10.7 27 5 33 305 42 2.8 49.2 31.7 01/29/2006 19:10:00 17 1.7 20.2 12.2 16.6 1.7 20.6 11.8 27 5 27 305 38.2 3.8 47 27.3 01/29/2006 19:20:00 16.5 1.8 21 11.5 16.1 1.8 20.2 11.8 26 5 23 305 39.4 4 47 24 01/29/2006 19:30:00 16.5 1.5 19.5 12.2 16.1 1.5 19.5 11.1 25 6 18 305 41.7 2.6 47.7 24.9 01/29/2006 19:40:00 15.1 1.7 18.7 10.7 14.7 1.7 18.3 11.1 24 7 22 305 41.9 4.2 46.3 27.3 01/29/2006 19:50:00 16.6 1.5 19.5 12.2 16.1 1.6 19.9 11.5 20 5 15 305 40.7 3.8 48.1 24 01/29/2006 20:00:00 16.4 1.7 19.5 11.5 16.2 1.5 19.1 11.8 21 5 23 305 43.3 3.2 49.5 27.6 01/29/2006 20:10:00 15.3 1.6 19.1 11.1 15 1.6 19.1 11.5 17 5 12 305 41.9 5.4 48.8 25.8 01/29/2006 20:20:00 15.6 1.4 19.1 11.8 15.2 1.4 18.7 11.5 27 7 33 305 39.3 5.4 51.8 27.9 01/29/2006 20:30:00 16.2 2.1 21 11.8 15.9 2.1 20.6 11.5 33 5 46 305 45.5 2.9 52.5 31.7 01/29/2006 20:40:00 15.1 1.7 19.5 11.1 14.8 1.7 19.1 10.3 33 6 39 305 45.8 2.1 51.4 34.3 01/29/2006 20:50:00 16.6 1.2 19.5 13.3 16.2 1.2 19.1 13 30 5 35 305 45 5.2 52.1 26.1 01/29/2006 21:00:00 15 1.6 18.7 11.1 14.6 1.5 17.9 11.1 30 6 30 305 46.8 3.7 52.9 26.4 01/29/2006 21:10:00 14.8 1.7 18.7 10.7 14.5 1.5 18.3 10.3 32 7 28 305 46.2 4.7 52.9 33.6 01/29/2006 21:20:00 14.2 1.5 17.9 10.7 13.8 1.5 17.2 10.3 29 6 35 305 44.1 4.2 51.4 30.4 01/29/2006 21:30:00 14.3 1.6 18.3 11.1 13.9 1.5 17.9 11.1 29 8 21 305 42.7 4.4 49.2 24.9 01/29/2006 21:40:00 14.2 1.7 17.9 10.3 14 1.8 17.9 10.3 24 7 21 305 44.3 2.3 49.5 31 01/29/2006 21:50:00 15 1.3 18.3 11.1 14.6 1.4 17.9 10.7 25 5 26 305 40.1 4.5 48.8 28.5 01/29/2006 22:00:00 14.4 1.7 18.3 10.3 14.2 1.7 18.7 10.7 25 6 25 305 40.9 4.7 48.4 31 01/29/2006 22:10:00 15.2 1.3 18.7 11.5 14.8 1.4 18.7 11.5 28 7 32 305 40.7 2.4 46.3 30.7 01/29/2006 22:20:00 14.9 1.8 18.3 11.1 14.6 1.8 18.7 10.3 24 6 18 305 40.6 2.1 44.8 31.7 01/29/2006 22:30:00 14.6 1.7 18.3 10.3 14.2 1.7 17.9 8.8 26 6 29 305 40 2.4 45.2 31.4 01/29/2006 22:40:00 16.3 2 20.2 11.5 15.8 1.9 19.9 10.7 27 5 27 305 39.9 2.2 45.9 26.1 01/29/2006 22:50:00 16.5 1.8 19.9 11.8 16.1 1.8 19.9 11.8 32 6 22 305 39.3 3.1 45.5 27 01/29/2006 23:00:00 16.9 1.7 19.9 11.8 16.6 1.9 20.2 10.3 33 5 36 305 39.6 2 44.5 33.3 01/29/2006 23:10:00 15.7 1.9 20.6 11.1 15.4 1.8 20.2 11.5 30 6 31 305 39.9 3.5 45.5 28.5 01/29/2006 23:20:00 15.5 1.7 19.9 11.5 15 1.7 19.5 11.1 27 5 32 305 39.5 2.6 45.5 30.1 01/29/2006 23:30:00 17.1 2.2 22.6 11.5 16.5 2.2 22.1 11.5 31 6 32 305 40.6 2.9 46.6 26.1 01/29/2006 23:40:00 15.9 2 21 11.5 15.5 1.9 19.9 10.7 32 6 31 305 40.5 2.8 45.9 26.4 01/29/2006 23:50:00 15.4 2 20.6 11.1 15.1 1.9 20.6 11.1 36 6 33 305 40.2 3.2 45.5 23.7 01/30/2006 00:00:00 16.7 1.7 20.6 12.2 16.3 1.8 19.9 11.5 35 5 38 305 39 2.8 44.8 29.8 01/30/2006 00:10:00 16.2 1.8 20.2 11.8 16 1.7 20.2 11.5 35 6 42 305 37.9 3.2 43.4 23.4 01/30/2006 00:20:00 15.8 1.5 19.9 12.2 15.3 1.5 19.5 11.8 36 6 41 305 38.5 3.1 44.5 26.7 01/30/2006 00:30:00 16 1.7 20.2 11.5 15.6 1.7 20.2 10.3 31 6 37 305 38.3 2.7 43.8 29.2 01/30/2006 00:40:00 16.5 2.1 21 10.7 16.2 2 21 11.5 29 6 33 305 38.2 2.6 43.1 26.4 01/30/2006 00:50:00 16.7 2 21.8 11.5 16.3 2 21.8 12.2 28 5 25 305 37 2.7 42 26.4 01/30/2006 01:00:00 18 1.8 22.6 14.1 17.6 1.8 22.1 12.6 29 5 25 305 37.6 3.1 43.1 26.1 01/30/2006 01:10:00 16.8 1.9 22.1 12.2 16.4 1.8 22.1 11.8 31 7 30 305 38.1 2.6 42 25.5 01/30/2006 01:20:00 16.5 1.6 20.2 11.8 16.1 1.7 20.2 11.8 36 5 29 305 33.9 3.5 42 25.2 01/30/2006 01:30:00 15.5 1.9 20.2 12.2 15.1 1.8 20.2 11.1 37 5 32 305 38.7 2.6 43.8 30.7 01/30/2006 01:40:00 16.5 1.9 21.4 12.6 16.1 1.8 21.4 12.2 36 6 32 305 36.6 1.7 40.3 26.1 01/30/2006 01:50:00 16.3 2 21.4 11.8 16.1 2.1 21.4 11.5 37 6 29 305 35 2.7 39.3 25.5 01/30/2006 02:00:00 15.7 1.8 19.5 11.8 15.4 1.8 19.5 11.5 36 6 44 305 33.1 3.5 38.9 27.9 01/30/2006 02:10:00 15.5 2 20.2 11.5 15.3 1.9 19.9 11.1 34 6 32 305 35.8 2.4 39.3 27.6 01/30/2006 02:20:00 16.9 1.9 21.4 11.1 16.5 1.9 21 12.2 32 6 34 305 35.8 2.4 38.9 28.5 01/30/2006 02:30:00 17.1 1.8 21.4 12.2 16.7 1.9 21.8 11.1 34 6 25 305 37 2.6 42.7 29.2 01/30/2006 02:40:00 16.6 1.9 20.6 11.8 16.2 1.9 20.2 11.8 29 6 33 305 37.8 2.7 42 26.1 01/30/2006 02:50:00 16.1 2.1 22.1 11.1 15.5 2 21 10.3 31 7 35 305 36.4 3.1 42.7 26.1 01/30/2006 03:00:00 17.4 2 22.1 11.5 16.8 1.9 21.4 11.5 27 6 28 305 38.3 2.6 43.4 30.1 01/30/2006 03:10:00 17.6 2.3 22.1 12.2 17.1 2.3 22.1 11.5 28 5 25 305 39.3 2.6 43.8 30.4 01/30/2006 03:20:00 18.8 2.1 22.6 13 18.4 2 23.3 13.3 27 6 40 305 38.2 3.4 43.8 23.1 01/30/2006 03:30:00 18.9 2.1 23.3 13.3 18.3 2.1 23.7 12.6 25 6 22 305 38.2 3.2 43.8 26.1 01/30/2006 03:40:00 19 2.2 23.7 13.7 18.6 2.1 22.9 13 30 6 31 305 38.8 2.6 44.5 26.7 01/30/2006 03:50:00 17.5 1.8 22.1 13.3 17 1.7 22.1 12.6 29 6 31 305 38.1 2.7 43.8 25.2 01/30/2006 04:00:00 18.5 2.1 23.3 13.3 18 2.1 22.9 13.3 29 6 27 305 37.8 2.9 43.1 26.1 01/30/2006 04:10:00 17.1 1.9 22.1 11.8 16.6 1.9 22.1 12.2 29 6 33 305 34.1 2.8 40.6 25.8 01/30/2006 04:20:00 16.5 2.1 21.8 10.3 16 2 20.6 11.1 31 6 31 305 34.8 2.9 43.8 24.9 01/30/2006 04:30:00 15.8 2 21.8 12.2 15.4 1.9 21.8 11.5 31 6 25 305 36.7 4.4 44.1 23.7 01/30/2006 04:40:00 17.3 2.5 22.9 12.6 16.9 2.4 22.9 12.2 32 6 27 305 33.3 5.4 42 17.6 01/30/2006 04:50:00 15.8 1.6 20.2 11.8 15.5 1.7 19.5 11.5 32 6 31 305 36.2 3.1 40.6 22.2 01/30/2006 05:00:00 15.1 2.1 19.5 10.3 14.8 1.9 19.5 10.7 32 6 29 305 36.2 3.5 42 20.7 01/30/2006 05:10:00 13.9 1.8 18.3 10.3 13.6 1.7 18.3 9.5 27 6 13 305 36.2 4.4 41.7 20.1 01/30/2006 05:20:00 16.3 1.8 21 11.5 15.8 1.7 20.6 11.5 30 6 36 305 36.8 5 42.7 13.7 01/30/2006 05:30:00 15.8 1.7 19.9 11.8 15.4 1.5 20.2 11.5 31 6 31 305 38.4 3.7 42.7 20.1 01/30/2006 05:40:00 14.6 1.8 20.2 10.3 14.4 1.7 19.9 10.3 32 6 24 305 38.1 4 43.8 19.6 01/30/2006 05:50:00 16.6 2 21.8 11.8 16.3 1.8 21 12.6 31 6 40 305 35.7 3.5 41 19.6 01/30/2006 06:00:00 17.4 1.8 21 12.6 16.9 1.7 20.2 11.5 31 6 33 305 36.4 3.1 40.6 13.4 01/30/2006 06:10:00 16.5 1.8 20.6 12.2 16 1.7 19.9 11.5 31 6 23 305 35.6 3.8 40.6 19 01/30/2006 06:20:00 16.7 1.7 21 11.5 16.2 1.7 20.2 11.5 29 6 23 305 34.6 5 41.3 18.1 01/30/2006 06:30:00 15.4 1.7 18.7 11.5 14.9 1.7 18.7 10.7 31 6 27 305 35.1 2.7 39.6 18.7 01/30/2006 06:40:00 16.8 1.6 21 12.2 16.4 1.7 20.6 12.2 31 6 25 305 34.7 1.4 37.9 20.4 01/30/2006 06:50:00 15.3 2.1 20.2 9.5 14.8 2 19.9 11.1 29 6 24 305 34.1 3.1 38.6 18.4 01/30/2006 07:00:00 14.4 1.7 18.3 10.3 14.1 1.7 18.3 9.9 31 6 28 305 35.3 3.7 40 19.6 01/30/2006 07:10:00 15.2 2 19.5 10.3 14.8 2 19.9 9.9 29 6 32 305 37.7 3.1 42.4 20.1 01/30/2006 07:20:00 14.4 1.6 18.3 9.9 14.2 1.6 18.3 10.7 31 5 24 305 37 2.3 41.3 26.7 01/30/2006 07:30:00 14 1.7 17.9 8.8 13.7 1.7 17.2 8.8 28 6 31 305 35.1 3.8 41 17.9 01/30/2006 07:40:00 14.7 1.7 18.3 11.1 14.2 1.7 17.9 10.3 30 6 33 305 36.7 2.6 41.3 23.7 01/30/2006 07:50:00 14.7 1.7 18.7 10.3 14.4 1.7 18.7 10.7 26 5 28 305 37.2 1.9 41.3 32 01/30/2006 08:00:00 14.6 1.6 18.3 10.3 14.2 1.6 17.6 10.3 27 6 35 305 37.4 3.2 42.4 21 01/30/2006 08:10:00 14.3 1.4 17.9 10.7 13.9 1.4 17.6 10.3 28 5 25 305 35.9 3.5 41.7 19 01/30/2006 08:20:00 13.1 1.5 16.8 9.9 12.8 1.4 16.4 9.1 27 6 20 305 36.3 2.7 41 23.4 01/30/2006 08:30:00 14.2 1.7 17.6 9.9 13.8 1.6 16.8 9.5 29 5 27 305 31.6 6.2 39.6 17.6 01/30/2006 08:40:00 14.7 1.3 18.3 11.1 14.3 1.5 17.9 11.1 30 6 34 305 24.1 2.7 29.8 12.4 01/30/2006 08:50:00 13.7 1.4 17.6 10.3 13.2 1.5 16.8 9.9 30 6 28 305 26.7 2.5 31 19.9 01/30/2006 09:00:00 14.4 1.6 17.6 10.3 14 1.7 17.2 9.1 27 5 28 305 26.1 2.3 30.4 19.3 01/30/2006 09:10:00 12 1.5 16.1 8.4 11.8 1.5 16.4 7.6 31 8 25 305 32.9 4.7 40 17 01/30/2006 09:20:00 12.3 1.3 15.6 9.1 12.2 1.3 15.6 9.5 34 6 37 305 34.7 2.8 40.3 17.3 01/30/2006 09:30:00 12.4 1.2 14.9 9.5 12.1 1.2 14.5 8.8 31 6 22 305 33.1 3.8 39.6 19.9 01/30/2006 09:40:00 11.9 1.5 15.3 8 11.7 1.5 14.9 8 25 6 24 305 31.6 4.4 37.9 15.3 01/30/2006 09:50:00 12.2 1.7 16.8 8.4 11.9 1.8 16.4 8.4 15 7 10 305 33.5 3.7 38.9 19 01/30/2006 10:00:00 13.3 1.4 16.8 9.9 13.3 1.5 17.6 9.5 11 6 18 305 35.3 2.2 40 16.7 01/30/2006 10:10:00 13.9 1.6 17.6 9.5 13.9 1.6 17.6 9.9 10 6 9 305 36.1 1.9 39.3 21.6 01/30/2006 10:20:00 13.4 1.3 17.2 9.9 13.2 1.4 17.2 9.5 18 6 22 305 35.9 2.3 39.3 17 01/30/2006 10:30:00 15.7 1.5 19.1 11.5 15.4 1.6 18.7 11.1 18 5 12 305 36.1 1.7 39.6 31.4 01/30/2006 10:40:00 15.4 1.6 19.5 11.1 15.1 1.7 19.5 10.7 20 6 8 305 35.9 1.5 39.3 32 01/30/2006 10:50:00 13.6 1.4 16.4 9.9 13.4 1.5 16.4 9.9 22 6 23 305 35.1 1.7 38.9 31.7 01/30/2006 11:00:00 14.6 2.2 19.5 9.9 14.4 2.2 19.5 9.9 16 6 21 305 34.8 2.4 39.6 20.7 01/30/2006 11:10:00 14 1.8 18.3 9.5 13.8 1.7 17.6 9.9 17 5 23 305 35.8 2.6 39.3 19.6 01/30/2006 11:20:00 14 1.3 17.2 9.9 13.9 1.3 16.8 10.3 18 6 17 305 34.7 2.3 41.7 29.8 01/30/2006 11:30:00 14 1.5 17.2 10.3 13.9 1.6 17.6 9.9 11 6 12 305 35.2 2.9 40.6 13.7 01/30/2006 11:40:00 13.6 1.5 17.2 10.3 13.4 1.5 17.6 9.9 8 6 7 305 32.6 3.2 39.3 18.7 01/30/2006 11:50:00 13.4 1.3 16.8 9.9 13.2 1.3 16.8 9.9 8 6 9 305 32.7 2.2 37.6 19.3 01/30/2006 12:00:00 14.7 2.1 19.5 9.9 14.6 2 19.1 10.3 13 6 12 305 32.6 2.1 37.6 26.4 01/30/2006 12:10:00 14.8 1.7 18.3 10.3 14.5 1.8 18.3 9.5 13 5 12 305 32.6 2.8 37.6 17.9 01/30/2006 12:20:00 14.7 1.2 17.6 10.7 14.4 1.2 17.2 11.5 14 5 19 305 33.2 2.3 38.3 23.4 01/30/2006 12:30:00 15.1 1.4 17.9 11.1 14.9 1.4 17.9 11.1 19 5 21 305 31 3.2 36.2 21.6 01/30/2006 12:40:00 14.9 1.2 18.7 10.7 14.7 1.3 17.6 9.9 20 5 22 305 38.7 4.7 44.1 19.9 01/30/2006 12:50:00 14.7 1.4 18.7 11.1 14.4 1.5 17.9 11.1 15 6 31 305 39.6 5.6 45.5 17.3 01/30/2006 13:00:00 13.9 1.8 17.9 9.5 13.7 1.7 17.9 9.9 13 5 14 305 38.1 5.2 43.8 16.7 01/30/2006 13:10:00 13.5 1.6 17.6 9.9 13.3 1.7 17.6 9.5 20 5 16 305 37 5 42.4 19.3 01/30/2006 13:20:00 15.5 1.5 18.7 11.1 15.3 1.5 18.3 11.1 22 5 29 305 31.3 7.6 43.4 19 01/30/2006 13:30:00 15.1 1.4 19.1 11.5 14.9 1.3 18.3 11.5 24 6 23 305 37.2 5.4 43.8 16.2 01/30/2006 13:40:00 14.2 1.5 17.6 10.7 14 1.5 18.3 11.1 20 6 23 305 37.1 4.7 42.4 19 01/30/2006 13:50:00 15.7 1.3 18.7 11.5 15.4 1.4 18.7 11.8 15 5 12 305 36.8 4.7 42 19.3 01/30/2006 14:00:00 15 1.7 19.1 10.7 14.7 1.7 18.3 10.7 21 7 21 305 36.6 4.2 42.7 19 01/30/2006 14:10:00 15.6 1.7 19.9 10.3 15.3 1.7 19.5 9.9 22 6 8 305 38.5 4 42.7 18.4 01/30/2006 14:20:00 15.1 1.5 19.1 10.3 14.8 1.5 19.1 11.1 16 6 12 305 39.3 4.4 43.1 17.9 01/30/2006 14:30:00 14.1 2.1 19.5 9.1 13.9 2.2 19.5 8.8 18 6 18 305 28.9 3.1 42.7 19.3 01/30/2006 14:40:00 16.2 1.5 19.5 11.8 15.9 1.6 19.9 12.2 19 5 15 305 39.4 5.2 44.5 15.3 01/30/2006 14:50:00 16.1 1.5 19.9 12.6 16 1.5 19.5 11.8 18 5 14 305 40.5 4.4 45.5 25.2 01/30/2006 15:00:00 16.7 1.8 20.2 12.2 16.5 1.8 20.6 11.5 18 5 13 305 40.8 3.7 44.8 27.6 01/30/2006 15:10:00 16.9 1.7 20.2 12.6 16.8 1.7 20.6 13 18 5 13 305 35.4 5.9 44.1 20.1 01/30/2006 15:20:00 16.8 1.9 20.6 11.8 16.5 1.8 20.6 11.8 17 6 18 305 32.9 6.2 46.3 20.1 01/30/2006 15:30:00 16.7 1.9 20.6 12.6 16.4 1.7 19.9 12.6 17 5 14 305 39.9 3.5 46.6 21.3 01/30/2006 15:40:00 16.1 2.3 20.2 10.3 15.8 2.2 20.2 11.1 19 5 15 305 39.9 4.4 46.6 21.9 01/30/2006 15:50:00 18.2 1.5 22.6 13.7 17.8 1.5 22.6 14.1 20 5 17 305 39 3.7 45.5 22.8 01/30/2006 16:00:00 17.2 1.4 21 13.3 16.8 1.4 21 13.3 23 5 23 305 39.7 2.8 45.5 27.9 01/30/2006 16:10:00 17 2 21.4 11.1 16.8 2 21 11.5 18 6 15 305 37 3.1 46.3 27 01/30/2006 16:20:00 17.9 1.8 22.1 13.3 17.4 1.9 22.1 13 17 5 15 305 38.3 2.3 42 32.6 01/30/2006 16:30:00 17 1.6 20.6 12.6 16.8 1.5 21 12.6 18 5 25 305 38.1 3.5 45.5 20.1 01/30/2006 16:40:00 18.1 1.7 21.4 13 17.6 1.8 21.8 11.8 22 5 22 305 37.7 2.9 43.8 21.3 01/30/2006 16:50:00 18.4 1.9 22.1 13.7 18 1.8 21.8 13.3 18 6 20 305 38 3.1 42.7 20.7 01/30/2006 17:00:00 18.6 1.7 22.1 13.7 18.3 1.7 22.1 13.7 22 6 23 305 35.7 3.2 42.4 21.6 01/30/2006 17:10:00 17.2 2.3 21.8 11.5 16.8 2 22.1 12.2 27 6 32 305 37.3 3.5 42.4 18.7 01/30/2006 17:20:00 17.6 2.3 22.6 11.8 17.2 2.4 22.6 11.1 25 6 23 305 38.8 3.1 43.8 20.4 01/30/2006 17:30:00 17.9 2.1 22.6 12.6 17.5 2 22.6 12.2 22 6 20 305 38.3 3.8 44.1 29.2 01/30/2006 17:40:00 18.6 1.6 21.8 14.5 18.2 1.6 22.1 14.1 25 5 31 305 39.1 2.9 42.7 22.5 01/30/2006 17:50:00 16.7 2.2 21.4 11.1 16.5 2 21 10.7 24 6 26 305 37.1 3.5 42 14.8 01/30/2006 18:00:00 17 1.7 21 12.6 16.6 1.8 20.6 11.8 17 6 14 305 38.3 4 44.1 20.7 01/30/2006 18:10:00 16.2 1.8 19.5 12.6 15.9 1.7 20.2 11.8 22 6 21 305 39 2.9 44.8 29.5 01/30/2006 18:20:00 16.9 1.6 20.6 12.6 16.4 1.5 20.2 12.6 27 6 30 305 38.6 3.4 44.8 22.8 01/30/2006 18:30:00 16.5 2.1 20.6 11.1 16.2 2.1 20.6 10.7 24 6 18 305 37 2.7 43.4 24 01/30/2006 18:40:00 18.2 1.8 22.6 13.3 17.9 1.7 22.9 13.7 20 6 17 305 37.6 2.8 43.4 22.2 01/30/2006 18:50:00 18.7 1.7 22.6 14.1 18.4 1.7 22.6 13.3 20 5 13 305 37.4 1.6 42.4 33.3 01/30/2006 19:00:00 17.5 1.8 22.1 13.3 17 1.9 22.1 12.6 25 5 23 305 38.6 1 42.7 35.6 01/30/2006 19:10:00 17.1 1.7 20.2 13 16.8 1.7 20.2 11.8 19 5 12 305 37.8 2.4 42.4 21.9 01/30/2006 19:20:00 16.4 1.6 19.9 13 16.1 1.5 19.9 11.5 20 6 13 305 38.4 3.8 43.4 19.6 01/30/2006 19:30:00 16.5 1.8 20.2 11.8 16.3 1.7 20.2 12.2 21 6 18 305 39.8 2 43.1 32 01/30/2006 19:40:00 16.5 1.8 20.6 12.2 16.2 1.9 20.6 11.5 20 6 28 305 36.9 2.1 43.8 30.4 01/30/2006 19:50:00 17.6 1.7 21 13 17.2 1.6 21 13.3 21 5 21 305 38.2 2 43.4 34.6 01/30/2006 20:00:00 17.6 2.1 21.4 11.8 17.2 1.9 20.6 11.8 20 5 21 305 37.3 1.3 41 34.3 01/30/2006 20:10:00 16.7 1.6 19.9 12.2 16.3 1.7 19.9 12.2 22 5 18 305 36.2 1.3 40 30.7 01/30/2006 20:20:00 16.1 1.5 19.9 12.6 16 1.5 19.5 11.8 22 6 15 305 36.4 5.2 46.6 18.7 01/30/2006 20:30:00 14.5 1.9 19.1 9.9 14.3 1.9 18.7 9.9 15 7 12 305 38.1 4.4 46.6 24.9 01/30/2006 20:40:00 14 1.6 17.2 10.3 13.9 1.7 17.9 9.1 7 5 5 305 38.4 3.4 45.5 34.6 01/30/2006 20:50:00 13.8 1.3 17.2 9.5 13.8 1.3 16.4 9.5 8 5 15 305 37.3 2.9 44.8 34.6 01/30/2006 21:00:00 14.1 1.2 16.8 10.3 13.9 1.3 16.8 10.3 9 5 7 305 37.2 3.1 43.8 34.3 01/30/2006 21:10:00 13 1.7 16.8 8.8 13 1.7 16.4 9.1 11 5 9 305 35.6 0.6 37.2 34.3 01/30/2006 21:20:00 13.9 1.5 17.9 9.9 13.9 1.6 18.3 8.8 11 6 15 305 35 0.8 37.2 33 01/30/2006 21:30:00 14.3 1.5 17.6 9.9 14.3 1.6 17.6 9.9 8 7 7 305 35.1 1 37.9 32.6 01/30/2006 21:40:00 13.9 1.5 16.8 10.3 13.8 1.6 17.2 9.5 5 5 10 305 36.1 0.6 37.9 33 01/30/2006 21:50:00 14.6 1.4 17.6 11.1 14.6 1.5 17.9 11.5 5 5 5 305 36 0.6 37.6 34.9 01/30/2006 22:00:00 14.7 1.2 18.3 11.1 14.7 1.3 17.9 11.1 3 5 2 305 36.6 0.8 38.9 34.3 01/30/2006 22:10:00 14.2 1.3 17.2 10.7 14.2 1.3 17.2 10.3 3 5 6 305 35.5 1 37.6 32.6 01/30/2006 22:20:00 14.8 1.3 17.6 10.3 14.7 1.4 17.9 10.7 4 4 3 305 34.9 1 37.2 32.6 01/30/2006 22:30:00 14.6 1.4 18.7 11.1 14.6 1.3 17.6 11.1 4 5 10 305 35.6 0.8 37.6 32.6 01/30/2006 22:40:00 13.4 1.3 16.8 10.3 13.3 1.3 16.4 9.5 3 5 0 305 35.6 0.5 37.2 34.6 01/30/2006 22:50:00 13 1.3 16.1 9.9 12.9 1.4 16.8 9.1 4 5 9 305 34.9 1.2 36.9 19.3 01/30/2006 23:00:00 12.9 1.3 16.1 9.9 12.9 1.4 16.1 9.5 7 6 16 305 33.8 2.2 36.6 15.3 01/30/2006 23:10:00 13.8 1.4 17.2 9.1 13.6 1.5 17.6 9.1 20 6 11 305 34.6 1 37.2 31.7 01/30/2006 23:20:00 14.3 1.4 18.3 10.7 13.9 1.5 18.3 10.3 24 6 19 305 35 0.7 36.9 31.7 01/30/2006 23:30:00 14.7 1.4 18.3 11.5 14.5 1.4 17.6 10.7 19 9 32 305 34.4 0.8 35.9 31.4 01/30/2006 23:40:00 13.8 1.3 16.8 10.3 13.7 1.4 17.2 9.9 6 5 2 305 32.8 1.1 35.3 30.4 01/30/2006 23:50:00 14 1.4 16.8 10.3 13.9 1.5 16.8 10.3 4 6 1 305 33.2 1 35.3 30.1 01/31/2006 00:00:00 14.2 1.5 17.2 10.7 14.1 1.5 17.9 9.9 5 5 3 305 33.4 1.7 35.9 27.6 01/31/2006 00:10:00 15.4 1.7 18.3 10.3 15.2 1.7 17.9 9.9 6 5 7 305 33.7 1.1 35.9 30.4 01/31/2006 00:20:00 13.8 1.7 17.9 9.9 13.6 1.7 17.6 9.9 6 5 1 305 33.9 2.5 37.9 10.5 01/31/2006 00:30:00 13.3 1.2 16.4 9.9 13 1.3 16.4 9.5 6 6 1 305 30.9 2 35.3 18.7 01/31/2006 00:40:00 13.6 1.3 17.2 9.9 13.4 1.4 16.8 10.3 9 5 8 305 31.8 1.5 34.3 26.4 01/31/2006 00:50:00 13.9 1.4 17.6 9.5 13.7 1.4 17.6 10.7 18 7 30 305 32.3 2.2 36.6 26.4 01/31/2006 01:00:00 13.7 1.5 17.2 9.9 13.5 1.7 17.2 8.8 13 8 8 305 31.8 2.1 35.9 24.3 01/31/2006 01:10:00 13.4 1.5 16.8 8.8 13.2 1.6 17.2 9.5 9 6 10 305 33 1.3 35.6 29.8 01/31/2006 01:20:00 12.4 1.3 16.1 9.1 12.4 1.2 15.3 9.1 4 6 356 305 33.2 1.3 35.9 29.2 01/31/2006 01:30:00 13 1.5 16.1 9.5 13 1.5 16.4 9.5 0 7 0 305 32.7 1.5 35.6 17.9 01/31/2006 01:40:00 14.4 1.3 16.8 10.3 14.4 1.3 17.2 10.7 358 5 4 305 31.3 1.7 33.9 18.1 01/31/2006 01:50:00 13.9 1.5 17.2 10.7 13.8 1.5 17.6 10.3 358 6 0 305 32.7 2.5 36.6 13.4 01/31/2006 02:00:00 13.9 1.4 16.8 9.5 14 1.4 16.8 9.9 2 5 0 305 31.9 1.9 36.6 22.5 01/31/2006 02:10:00 14.6 1.3 17.6 11.1 14.6 1.4 17.6 11.1 0 5 3 305 32.2 2.3 35.3 10.5 01/31/2006 02:20:00 14.5 1.5 17.6 9.9 14.4 1.6 17.6 10.3 0 5 359 305 31.8 1.3 34.9 27.6 01/31/2006 02:30:00 13.8 1.7 16.4 9.1 13.5 1.7 17.6 9.5 359 6 2 305 31.5 1.7 34.3 13.7 01/31/2006 02:40:00 14.1 1.3 16.8 9.5 13.9 1.4 16.8 9.5 3 5 8 305 31 2.4 36.2 11.8 01/31/2006 02:50:00 14.2 1.3 16.4 10.3 13.9 1.5 17.2 9.9 3 5 2 305 38.9 1.9 42 26.7 01/31/2006 03:00:00 12.6 1.5 15.6 8.8 12.6 1.4 15.6 8.8 1 6 0 305 37.7 2.7 42 29.5 01/31/2006 03:10:00 12.8 1.2 15.3 9.1 12.7 1.3 15.6 9.5 358 5 356 305 35.3 2.3 40.6 27.6 01/31/2006 03:20:00 12.2 1.5 16.4 8.4 12.2 1.5 16.1 8.8 358 6 358 305 33.3 3.2 38.9 26.4 01/31/2006 03:30:00 13.5 1.7 16.4 9.9 13.4 1.9 17.2 8.8 359 5 359 305 31.2 1.4 33.6 25.8 01/31/2006 03:40:00 13.5 1.3 16.8 9.5 13.3 1.3 16.1 9.5 3 5 7 305 31.7 1.5 35.3 27.6 01/31/2006 03:50:00 13.3 1.3 16.4 9.5 13.3 1.4 17.6 9.5 2 5 3 305 31.4 1.4 33.9 26.7 01/31/2006 04:00:00 13.1 1.3 15.6 9.5 12.9 1.5 15.6 8.8 5 5 6 305 34.5 3.5 41.7 26.7 01/31/2006 04:10:00 12.4 1.1 15.3 9.1 12.3 1.1 14.9 9.5 6 5 11 305 36.6 1.3 40 33.3 01/31/2006 04:20:00 12.6 1.4 15.3 9.1 12.6 1.4 15.6 9.1 6 5 6 305 33.2 2.9 38.9 24.9 01/31/2006 04:30:00 13.4 1.3 16.1 8.8 13.3 1.2 16.4 9.9 5 4 8 305 34.9 2.8 38.6 26.1 01/31/2006 04:40:00 12.5 1.2 15.3 9.5 12.5 1.2 16.1 9.5 2 5 0 305 35.2 2.1 38.6 27.3 01/31/2006 04:50:00 11.5 1.3 15.3 8.4 11.5 1.3 14.9 8.4 2 5 0 305 35.7 5.4 44.8 14.3 01/31/2006 05:00:00 12.6 1.2 15.6 9.5 12.6 1.3 16.1 9.5 4 5 2 305 42.4 1.5 45.9 37.6 01/31/2006 05:10:00 12 1.5 15.3 8 11.7 1.5 15.6 8.4 6 5 11 305 39.3 2.5 42.4 3.2 01/31/2006 05:20:00 13.2 1.2 15.6 9.9 13.1 1.2 16.1 9.9 5 5 355 305 37.6 3.2 42 21 01/31/2006 05:30:00 12.9 1.2 15.3 9.5 12.7 1.2 15.6 9.9 6 4 6 305 36.5 2.3 40.6 22.2 01/31/2006 05:40:00 11.8 1.4 14.5 9.1 11.8 1.4 14.9 8.4 1 5 2 305 35.7 5.2 44.8 12.4 01/31/2006 05:50:00 12.4 1.5 14.9 8.4 12.4 1.5 15.3 8.8 359 4 0 305 30 3.7 40.6 11.8 01/31/2006 06:00:00 11.5 1.3 14.5 8.4 11.4 1.3 14.5 8.8 1 5 5 305 31.5 4 44.8 26.7 01/31/2006 06:10:00 11.5 1.4 14.1 7.2 11.6 1.3 14.5 8.4 1 5 358 305 37.7 2.1 42.7 24.9 01/31/2006 06:20:00 11.3 1.5 14.5 8 11.3 1.5 14.9 8 3 6 357 305 34.3 4.2 39.3 10 01/31/2006 06:30:00 12 1.1 14.1 9.1 12.1 1.1 14.9 9.5 2 6 359 305 25.3 1.9 29.2 11.8 01/31/2006 06:40:00 12.4 1.2 14.9 8.8 12.4 1.2 15.3 9.1 2 5 6 305 32.6 3.5 37.2 5.4 01/31/2006 06:50:00 11.8 1.2 14.5 8 11.8 1.4 14.5 8.8 4 6 7 305 29.2 4.7 37.9 9.5 01/31/2006 07:00:00 12.7 1 14.5 9.5 12.6 1.3 15.3 9.1 4 4 3 305 32.2 4.7 40.6 9.2 01/31/2006 07:10:00 12.4 1.2 15.3 9.1 12.2 1.2 15.6 8.4 5 5 11 305 34.8 1.4 38.3 31.4 01/31/2006 07:20:00 12.3 1.2 14.5 9.5 12.1 1.2 14.5 8.8 3 5 5 305 29.8 4.2 37.2 12.4 01/31/2006 07:30:00 11.8 1.2 14.5 8.4 11.6 1.2 14.5 8 5 5 351 305 30.8 3.7 36.6 12.1 01/31/2006 07:40:00 11.1 1.3 14.1 7.2 10.9 1.5 14.5 6.8 7 6 7 305 29.1 4.5 36.2 9.5 01/31/2006 07:50:00 12.5 1.3 15.3 8.4 12.3 1.3 16.1 8.8 8 5 5 305 29.2 3.7 34.6 8.4 01/31/2006 08:00:00 13 1.5 16.1 9.1 12.8 1.6 15.6 8.8 8 6 7 305 28.6 4.2 38.6 10.8 01/31/2006 08:10:00 12.1 1.2 14.9 9.1 11.9 1.3 14.9 8.4 10 5 12 305 31.8 4 37.9 8.9 01/31/2006 08:20:00 12.1 1.2 14.9 9.1 12.1 1.3 15.3 9.1 10 5 12 305 31.3 4 36.9 21.3 01/31/2006 08:30:00 11.4 1.2 14.5 8 11.6 1.2 14.5 8 9 5 8 305 33.2 2.8 39.6 21 01/31/2006 08:40:00 10.6 1.3 13.7 7.6 10.5 1.3 14.1 7.2 6 6 0 305 33.2 2.8 40.3 21.3 01/31/2006 08:50:00 11.6 1.2 14.9 8 11.4 1.3 14.5 8 8 5 10 305 30.4 3.5 34.9 17.6 01/31/2006 09:00:00 11.3 1.3 14.5 7.2 11.2 1.4 14.5 7.6 6 5 0 305 29.2 1.9 34.9 21.3 01/31/2006 09:10:00 12.2 1.3 15.3 8.8 12.2 1.3 15.3 8.8 9 5 11 305 29 1.2 31.7 20.7 01/31/2006 09:20:00 12.5 1.2 16.4 9.5 12.2 1.3 16.1 9.1 6 6 8 305 29.2 1.2 31.4 22.2 01/31/2006 09:30:00 13.3 1.3 17.2 10.7 13.3 1.3 16.8 10.3 7 5 7 305 29 1.1 31.4 26.1 01/31/2006 09:40:00 13 1.3 16.1 9.5 12.8 1.3 16.4 9.9 8 5 6 305 29 1.1 31 24.9 01/31/2006 09:50:00 12.4 1.2 15.3 9.5 12.3 1.3 15.3 9.5 8 5 12 305 28 1.5 30.1 9.7 01/31/2006 10:00:00 12 1.5 16.1 8.8 11.9 1.5 16.1 8.8 9 6 13 305 28.8 1.5 30.7 11.6 01/31/2006 10:10:00 11.8 1.2 14.9 8 11.6 1.2 14.9 8.4 10 6 6 305 28.4 2.1 31 10.8 01/31/2006 10:20:00 11.4 1.1 14.5 8.4 11.3 1.2 14.5 8.8 11 6 9 305 26.9 1 29.8 19.3 01/31/2006 10:30:00 10.9 1.2 13.7 8 10.9 1.2 14.1 7.6 10 5 12 305 28.2 2.3 32.6 6.9 01/31/2006 10:40:00 11 1.2 13.7 8 10.8 1.2 13.7 8 7 6 1 305 28.8 2.1 32 4.9 01/31/2006 10:50:00 11.2 1.2 14.1 7.6 11.1 1.3 14.1 7.2 5 6 3 305 28.1 1.4 31 13.7 01/31/2006 11:00:00 12.4 1.5 15.3 8.4 12.1 1.5 14.9 8.8 3 6 355 305 27.1 1.5 29.5 11 01/31/2006 11:10:00 11.9 1.5 15.3 8.4 11.7 1.5 15.6 8 8 6 8 305 26.4 3.5 30.7 5.2 01/31/2006 11:20:00 12.2 1.3 15.6 8.8 12 1.3 16.1 9.1 8 6 4 305 28.4 1.1 30.4 22.2 01/31/2006 11:30:00 11.9 1.4 15.3 8.8 11.7 1.3 14.9 8.8 10 7 1 305 27.2 2 30.4 6.4 01/31/2006 11:40:00 12.7 1.9 16.4 8 12.7 1.8 16.8 8.4 11 6 6 305 27.7 3.4 34.9 4.9 01/31/2006 11:50:00 13 1.4 16.1 9.9 12.8 1.5 16.4 8.4 9 5 8 305 29.9 3.4 33.6 -0.6 01/31/2006 12:00:00 13.3 1.3 16.8 10.3 13.2 1.4 16.4 9.5 7 5 5 305 27.4 1.5 30.7 21.6 01/31/2006 12:10:00 12.6 1.2 15.6 9.5 12.2 1.2 15.3 8.8 10 7 4 305 27 2.1 29.8 5.6 01/31/2006 12:20:00 12.1 1.3 14.9 8.8 11.7 1.3 14.9 8.4 18 6 15 305 27.6 4.4 31.4 6.7 01/31/2006 12:30:00 11.3 1.2 14.9 8 11.4 1.2 15.3 8.8 19 6 17 305 26.5 5.9 31.4 4.9 01/31/2006 12:40:00 11.2 1.3 14.5 7.2 11.1 1.4 14.5 7.2 12 6 13 305 29.2 2.7 33.6 7.7 01/31/2006 12:50:00 10 1.1 13.3 6.8 9.9 1.1 13.3 6.8 11 7 13 305 28.5 2.5 35.6 16.2 01/31/2006 13:00:00 11.1 1.1 14.1 8 11.1 1.2 14.5 8.4 8 5 0 305 28.9 3.2 34.3 1 01/31/2006 13:10:00 10.4 1.5 13.7 6.8 10.3 1.4 13.3 6.8 10 6 353 305 27.7 2.8 32.6 6.4 01/31/2006 13:20:00 10.5 1.2 13.3 7.6 10.5 1.2 13.3 7.6 9 5 12 305 25.1 3.8 33 7.2 01/31/2006 13:30:00 10.3 1.1 13 6.8 10.2 1.1 13 6.8 10 6 10 305 28.6 3.8 33.6 6.7 01/31/2006 13:40:00 9.5 1.3 12.6 6.1 9.4 1.4 12.6 6.8 13 6 13 305 27.8 4 33.3 1.5 01/31/2006 13:50:00 10.8 1.2 13 7.2 10.5 1.2 13.3 7.6 10 6 4 305 26.9 3.7 32.6 11.8 01/31/2006 14:00:00 9.3 1.1 11.8 5.7 9.1 1.2 11.5 5.7 10 6 2 305 26.1 4 32.3 4.9 01/31/2006 14:10:00 9.3 1 11.5 6.1 9.3 1.1 11.5 6.1 14 6 7 305 27.9 1 31 19.6 01/31/2006 14:20:00 9.6 0.9 11.5 7.2 9.5 1 11.5 7.2 9 4 12 305 26.4 5.6 31 7.9 01/31/2006 14:30:00 9.5 0.8 11.1 7.2 9.5 0.8 11.5 6.8 10 5 14 305 26.7 5.6 31 2.7 01/31/2006 14:40:00 9.3 0.7 11.1 6.8 9.5 0.8 11.5 7.2 10 5 9 305 26.4 5.4 30.4 5.9 01/31/2006 14:50:00 9.8 1.1 12.2 6.8 9.7 1.1 12.2 6.5 6 5 1 305 27.3 3.1 33.6 8.2 01/31/2006 15:00:00 9.7 0.9 11.8 7.6 9.7 1 12.2 6.8 6 5 8 305 27.3 2.9 33.3 9.5 01/31/2006 15:10:00 9.3 0.9 11.5 6.1 9.3 1 11.8 6.1 4 5 2 305 30.3 2.8 35.3 18.4 01/31/2006 15:20:00 9.7 0.9 12.2 7.6 9.8 1 11.8 6.8 3 5 4 305 29.6 2.3 34.9 22.2 01/31/2006 15:30:00 9.4 1 11.8 6.8 9.3 1.1 11.8 6.5 8 6 8 305 27.3 2.4 32.6 2.7 01/31/2006 15:40:00 9.1 1.1 11.5 6.1 9 1.1 11.8 5.7 11 7 17 305 27.3 2.8 33.3 7.9 01/31/2006 15:50:00 9.5 1 11.8 6.8 9.5 1.1 11.8 6.5 17 6 22 305 27.4 3.2 33.3 20.7 01/31/2006 16:00:00 10.1 1 12.6 7.6 10.1 1.2 13.3 6.8 11 8 12 305 27.6 3.1 33 14.8 01/31/2006 16:10:00 10.3 1 12.6 7.6 10.2 1 13 7.2 8 6 4 305 28.7 3.4 33.3 2.9 01/31/2006 16:20:00 10.4 0.9 12.2 7.6 10.3 0.9 12.2 7.6 9 5 9 305 28.6 2.7 34.6 18.7 01/31/2006 16:30:00 10 1.3 12.6 6.5 10 1.5 13 6.5 9 6 8 305 28.1 2.9 33.6 23.4 01/31/2006 16:40:00 10.8 1.1 13 7.6 10.8 1.1 13 8 10 5 6 305 29.6 3.2 36.9 23.4 01/31/2006 16:50:00 9.7 1 12.6 6.8 9.7 1 12.2 6.5 15 6 15 305 29.6 3.1 34.9 10.2 01/31/2006 17:00:00 9.8 1 11.8 6.8 9.7 1.1 12.2 6.5 15 5 15 305 30.7 2.8 34.9 11 01/31/2006 17:10:00 8.9 0.9 10.7 6.5 8.8 0.9 11.1 6.5 16 6 20 305 30.6 2.9 36.6 16.5 01/31/2006 17:20:00 9.4 0.9 11.5 6.8 9.2 1 11.5 6.1 15 5 10 305 29.9 3.4 34.9 10.8 01/31/2006 17:30:00 8.7 0.8 10.3 6.1 8.7 0.8 10.7 6.5 15 6 12 305 29.6 2.7 34.6 8.2 01/31/2006 17:40:00 8.2 1 10.3 5.3 8 1.1 10.3 5.3 18 7 26 305 29 1.5 35.6 16.7 01/31/2006 17:50:00 7.6 1.1 10.7 4.6 7.5 1.2 10.3 4.9 15 6 13 305 31.1 2.3 35.9 23.7 01/31/2006 18:00:00 8.6 0.9 10.7 6.1 8.5 1 11.1 5.7 20 5 12 305 29.1 0.9 34.9 23.4 01/31/2006 18:10:00 8.6 1.1 11.1 5.7 8.6 1.2 11.1 5.7 15 7 18 305 27.8 2.1 33.3 6.1 01/31/2006 18:20:00 8 1.2 10.3 5.7 7.9 1.3 11.5 4.9 16 9 7 305 28.8 2.9 35.3 6.9 01/31/2006 18:30:00 8.4 0.8 9.9 6.1 8.4 0.8 10.7 6.1 10 7 10 305 29 2.9 36.6 21.9 01/31/2006 18:40:00 7.8 0.8 9.5 5.7 7.8 0.8 9.5 5.3 9 6 4 305 28.2 3.2 37.2 10 01/31/2006 18:50:00 7.3 0.7 9.1 4.9 7.3 0.7 8.8 5.3 8 6 359 305 28 7 37.9 5.2 01/31/2006 19:00:00 6.2 0.7 7.6 4.6 6 0.7 7.6 4.2 29 7 23 305 31.8 3.8 37.9 2 01/31/2006 19:10:00 5.4 0.6 6.8 4.2 5.2 0.7 7.2 3.8 27 6 23 305 31.4 3.1 37.6 24.9 01/31/2006 19:20:00 5.9 0.6 7.2 4.6 5.8 0.6 7.2 4.6 28 6 26 305 33.2 4 39.3 8.2 01/31/2006 19:30:00 5.6 0.6 7.2 3.8 5.4 0.7 7.2 3.8 24 5 29 305 32.9 7 37.9 6.9 01/31/2006 19:40:00 5.5 0.6 7.2 4.2 5.3 0.6 7.2 3.8 24 6 14 305 31.8 5 37.9 4.9 01/31/2006 19:50:00 6.2 0.7 7.2 4.2 6 0.7 7.2 4.2 22 6 16 305 30.3 7 37.6 7.4 01/31/2006 20:00:00 5.3 0.5 6.8 4.2 5.2 0.5 6.8 3.8 28 6 29 305 32.6 4.5 37.9 7.7 01/31/2006 20:10:00 5.2 0.6 6.8 4.2 5.1 0.6 6.8 3.8 20 6 17 305 33.3 3.7 37.6 10 01/31/2006 20:20:00 4.8 0.5 6.1 3.4 4.6 0.6 5.7 3 32 7 26 305 32.9 4.4 37.9 9.2 01/31/2006 20:30:00 6.1 0.8 8 4.2 5.9 0.8 8 3.8 25 5 22 305 33.4 2.3 36.6 6.9 01/31/2006 20:40:00 5.5 0.7 7.6 3.8 5.3 0.8 7.2 3.8 23 7 28 305 31.4 3.7 36.6 10.5 01/31/2006 20:50:00 6 0.7 7.6 4.2 5.8 0.7 7.6 3.4 20 5 24 305 32.9 3.2 37.2 14.5 01/31/2006 21:00:00 5.9 0.9 7.2 3 5.8 0.9 7.6 3 35 6 31 305 32.1 4 36.9 8.2 01/31/2006 21:10:00 5.8 0.5 7.2 4.6 5.6 0.6 7.2 4.2 31 9 35 305 31.4 3.5 36.6 7.4 01/31/2006 21:20:00 5.5 0.6 6.8 3.8 5.4 0.6 7.2 4.2 28 6 25 305 31 5.2 35.3 4.4 01/31/2006 21:30:00 5.1 0.6 6.1 3.8 5 0.6 6.1 3.4 34 6 36 305 31.9 4.5 36.2 4.4 01/31/2006 21:40:00 5.1 0.7 6.5 3.4 4.9 0.6 6.5 3.4 42 5 32 305 30.6 5.6 35.9 3.9 01/31/2006 21:50:00 4.4 0.4 5.3 3.4 4.3 0.4 5.3 3 43 7 48 305 31.1 5.2 36.9 4.9 01/31/2006 22:00:00 4.8 0.4 5.7 3.8 4.5 0.4 5.3 3 42 5 45 305 31.9 4.5 37.9 5.2 01/31/2006 22:10:00 4.6 0.4 6.1 3.4 4.4 0.4 5.7 3.4 37 5 39 305 31.5 3.7 37.6 6.4 01/31/2006 22:20:00 4.8 0.5 5.7 3.4 4.6 0.5 5.7 3.4 32 5 38 305 31 5.4 36.6 5.4 01/31/2006 22:30:00 4.4 0.6 5.7 3.4 4.2 0.5 5.3 3 38 9 33 305 31.4 5.4 36.2 3.7 01/31/2006 22:40:00 4 0.4 4.9 3 3.7 0.4 4.6 2.6 56 5 65 305 30.9 4.5 35.9 4.9 01/31/2006 22:50:00 4.6 0.4 5.3 3.4 4.3 0.4 4.9 3 65 3 65 305 31.5 3.8 35.3 7.7 01/31/2006 23:00:00 4.5 0.3 5.3 3.4 4.2 0.4 4.9 3.4 62 4 68 305 30.7 5.6 36.6 5.2 01/31/2006 23:10:00 4.5 0.4 5.3 3.4 4.1 0.4 4.9 3 57 4 65 305 30.4 5 36.2 5.2 01/31/2006 23:20:00 4.1 0.3 4.9 3 3.7 0.4 4.6 3 65 4 61 305 30 5.4 35.6 4.4 01/31/2006 23:30:00 3.7 0.4 4.9 3 3.4 0.4 4.6 2.6 72 9 59 305 30.6 4.2 35.3 6.1 01/31/2006 23:40:00 3.2 0.4 4.2 2.3 2.8 0.4 3.8 1.9 78 8 75 305 29.8 4.4 35.3 4.2 01/31/2006 23:50:00 3.2 0.5 4.6 2.3 2.9 0.6 4.2 1.5 108 13 108 305 29.9 4.5 34.6 2.2 02/01/2006 00:00:00 3 0.6 4.6 1.5 2.9 0.8 4.2 0.7 104 17 108 305 29.2 5.9 34.9 1.3 02/01/2006 00:10:00 2.8 0.5 4.2 1.5 2.5 0.4 3.8 1.1 94 13 97 305 25.6 6.4 32.6 -4.5 02/01/2006 00:20:00 3.5 0.6 4.9 2.3 3 0.6 4.9 1.9 92 11 88 305 23.6 8 31 -4.7 02/01/2006 00:30:00 3.3 0.4 4.2 2.3 2.8 0.4 4.2 1.9 83 10 88 305 23.3 6.4 30.4 -5.6 02/01/2006 00:40:00 2.5 0.3 3.4 1.5 2.2 0.3 3 1.5 74 9 68 305 22.3 8 30.7 -2.7 02/01/2006 00:50:00 1.2 0.6 3 0.4 0.9 0.5 2.3 0.4 133 39 89 305 25.5 4.7 30.7 -2.4 02/01/2006 01:00:00 1.4 0.5 2.3 0.4 1 0.5 1.9 0.4 105 23 123 305 22.7 6.2 30.7 -6 02/01/2006 01:10:00 1 0.7 2.6 0.4 1 0.7 2.6 0.4 137 58 200 305 18 11.3 31.7 -4.5 02/01/2006 01:20:00 1 0.4 2.3 0.4 1.3 0.6 2.6 0.4 184 35 188 305 21.7 8.3 31 -3.8 02/01/2006 01:30:00 2 0.3 3 0.7 2 0.3 2.6 1.1 206 6 213 305 24.3 6.7 31.7 -2.9 02/01/2006 01:40:00 1.5 0.5 2.6 0.4 1.9 0.5 3 0.4 184 17 184 305 20.8 9.1 30.7 -2.7 02/01/2006 01:50:00 1.4 0.6 3 0.4 1.6 0.6 3.4 0.4 143 14 137 305 21.1 6.2 25.2 -2.4 02/01/2006 02:00:00 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 117 6 118 305 22 4.2 24.9 0.1 02/01/2006 02:10:00 0.9 0.6 2.6 0.4 1.1 0.8 2.6 0.4 152 32 148 305 21.4 4.4 25.2 -3.6 02/01/2006 02:20:00 1.4 0.7 3.4 0.4 1.7 0.6 3.4 0.4 178 12 193 305 20.6 4.2 24 -3.6 02/01/2006 02:30:00 1.8 0.6 3.4 0.4 1.8 0.6 3 0.4 150 15 152 305 19.3 5.9 23.7 -5.8 02/01/2006 02:40:00 0.5 0.3 1.5 0.4 0.6 0.4 2.3 0.4 126 9 131 305 19.8 5.4 23.7 -5.1 02/01/2006 02:50:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 116 7 97 305 19.3 5.4 24 -5.6 02/01/2006 03:00:00 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 112 27 94 305 20.1 5.4 26.1 -4.9 02/01/2006 03:10:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 101 24 131 305 19.1 6.4 24 -5.6 02/01/2006 03:20:00 1.6 1 3.8 0.4 1.6 0.9 3.8 0.4 148 18 151 305 18.4 8 23.7 -26.1 02/01/2006 03:30:00 1.8 0.7 3.8 0.4 1.6 0.7 3 0.4 145 20 149 305 19.3 6.7 28.8 -8.2 02/01/2006 03:40:00 2.7 1.3 4.6 0.4 2.7 1.5 4.2 0.4 144 17 136 305 17.8 9.1 30.7 -8.6 02/01/2006 03:50:00 4.3 0.5 5.3 2.3 4.1 0.8 5.3 2.3 138 4 138 305 13.2 11.3 28.8 -8.4 02/01/2006 04:00:00 3.5 0.7 5.7 0.4 3.3 1.2 4.9 0.4 121 17 123 305 14.9 11.3 29.5 -10.7 02/01/2006 04:10:00 0.9 0.5 2.6 0.4 0.6 0.4 1.9 0.4 157 76 129 305 17.1 9.5 28.8 -14.3 02/01/2006 04:20:00 0.6 0.4 2.3 0.4 0.4 0.2 1.9 0.4 114 82 124 305 21.8 6.2 28.5 -18.1 02/01/2006 04:30:00 0.8 0.5 2.6 0.4 0.6 0.4 2.3 0.4 337 90 82 305 21.8 2.1 27.3 -6.4 02/01/2006 04:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 38 58 63 305 20.6 3.8 28.2 -4.5 02/01/2006 04:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 262 61 197 305 20 2.5 22.5 -9 02/01/2006 05:00:00 0.7 0.5 2.3 0.4 0.7 0.5 1.9 0.4 111 28 134 305 20.1 1.8 24.6 -3.3 02/01/2006 05:10:00 0.6 0.4 2.3 0.4 0.4 0.2 1.5 0.4 140 35 109 305 22 4 27.6 -6.2 02/01/2006 05:20:00 0.7 0.4 2.3 0.4 0.4 0.2 1.1 0.4 144 38 119 305 20.2 2.9 22.8 -7.7 02/01/2006 05:30:00 1 0.7 2.6 0.4 0.6 0.3 1.9 0.4 118 49 116 305 13.4 5.6 26.4 -1.8 02/01/2006 05:40:00 0.9 0.6 3 0.4 0.7 0.3 1.5 0.4 327 86 129 305 -0.5 5.6 8.2 -22.2 02/01/2006 05:50:00 1 1.1 4.6 0.4 0.8 0.9 4.2 0.4 247 69 127 305 -4.5 5.6 5.9 -24.6 02/01/2006 06:00:00 3.2 0.5 4.6 1.5 3.3 0.6 4.6 1.9 112 11 127 305 -5.9 4 2.7 -23.4 02/01/2006 06:10:00 3 0.9 4.9 0.4 2.8 0.9 4.6 0.4 134 22 148 305 -7.2 4.5 -0.4 -24.1 02/01/2006 06:20:00 3.6 0.6 4.9 1.5 3.7 0.7 4.9 0.7 131 12 145 305 -7.4 6.2 4.9 -26.1 02/01/2006 06:30:00 3.2 0.7 4.6 1.1 3.7 0.8 5.3 1.1 123 12 125 305 -1.1 8 11.3 -25.1 02/01/2006 06:40:00 3.2 0.4 4.6 1.9 3.4 0.5 4.6 2.3 118 12 128 305 1.6 6.4 9.5 -22.2 02/01/2006 06:50:00 3.3 0.5 4.9 1.9 3.4 0.5 4.6 2.3 114 9 105 305 4.9 5 11.3 -20.8 02/01/2006 07:00:00 3 0.5 4.2 1.1 2.1 1 4.2 0.4 118 10 116 305 5.8 7 12.9 -26.1 02/01/2006 07:10:00 3.2 0.9 4.6 0.4 2.5 1.1 3.8 0.4 117 10 116 305 7.7 7 16.5 -24.9 02/01/2006 07:20:00 1 1 3.8 0.4 0.7 0.5 2.6 0.4 290 98 119 305 9.9 6.2 17 -19 02/01/2006 07:30:00 3.8 0.3 4.6 3 3.7 0.5 4.6 1.5 115 4 108 305 10.5 2.3 15.3 -12.3 02/01/2006 07:40:00 3.9 0.3 4.9 3 3.9 0.3 4.9 3 117 5 121 305 10.6 5.2 17.6 -13.1 02/01/2006 07:50:00 3.9 0.4 4.9 2.6 4.1 0.4 4.9 2.6 118 8 126 305 10.2 4.4 16.5 -14.3 02/01/2006 08:00:00 3.5 0.5 4.9 2.3 3.5 0.5 4.6 1.9 113 10 103 305 10.4 4.2 15.6 -13.7 02/01/2006 08:10:00 3.8 0.5 5.3 2.6 3.7 0.5 4.9 1.9 107 9 112 305 8.4 4.4 15.6 -20.8 02/01/2006 08:20:00 3.2 0.6 4.9 1.9 3.2 0.5 4.6 1.9 106 9 92 305 8.6 4 13.2 -16.9 02/01/2006 08:30:00 3.4 0.6 5.3 1.9 3.2 0.7 5.3 1.5 97 13 107 305 8.6 4.7 18.7 -19.2 02/01/2006 08:40:00 2.8 0.7 4.9 1.5 2.4 0.7 4.6 0.7 81 12 81 305 11.4 6.7 19 -12.9 02/01/2006 08:50:00 1.9 0.3 3 0.7 2 0.4 3 0.7 106 10 117 305 12 6.2 17.3 -12.9 02/01/2006 09:00:00 2.1 0.3 3 1.5 2.2 0.3 3 1.5 112 6 121 305 10 9.5 19.6 -13.7 02/01/2006 09:10:00 1.6 0.5 2.6 0.4 1.3 0.5 2.3 0.4 105 13 112 305 13 7.6 20.4 -12.1 02/01/2006 09:20:00 1.1 0.7 2.6 0.4 0.7 0.6 2.3 0.4 89 19 93 305 12.8 8.7 20.1 -12.5 02/01/2006 09:30:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 51 19 65 305 12.4 8.7 19.9 -12.1 02/01/2006 09:40:00 0.6 0.5 2.6 0.4 0.7 0.5 2.6 0.4 93 66 167 305 12.8 7 19.6 -11.9 02/01/2006 09:50:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 143 43 254 305 13.1 3.5 19.6 -11.1 02/01/2006 10:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 316 76 275 305 13.2 2.6 19 -12.5 02/01/2006 10:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 83 35 56 305 14 3.4 19.6 -13.3 02/01/2006 10:20:00 0.6 0.4 2.6 0.4 0.4 0.2 1.1 0.4 81 32 124 305 13.8 3.7 21.3 -12.5 02/01/2006 10:30:00 0.9 0.6 2.6 0.4 0.8 0.4 2.3 0.4 85 43 105 305 13.2 3.4 19.6 -13.1 02/01/2006 10:40:00 1.1 0.7 3.4 0.4 0.9 0.6 2.6 0.4 94 26 110 305 13 4.7 19 -12.3 02/01/2006 10:50:00 1.2 0.6 2.6 0.4 0.7 0.4 1.9 0.4 110 22 118 305 11.4 8.3 19.9 -12.5 02/01/2006 11:00:00 2.1 0.6 3.4 0.4 1.6 0.8 3 0.4 107 12 119 305 12.5 7.6 19.9 -12.1 02/01/2006 11:10:00 2.2 0.3 3 1.5 2 0.3 2.6 1.5 103 5 94 305 13.3 5.9 20.1 -12.3 02/01/2006 11:20:00 2.2 0.3 3 1.5 2.1 0.2 2.6 1.5 104 9 93 305 13 5 20.1 -11.9 02/01/2006 11:30:00 2.3 0.4 3.4 1.5 2.2 0.3 3 1.5 108 9 111 305 12.1 5.9 19 -16 02/01/2006 11:40:00 3 0.5 4.2 1.9 2.4 0.4 3.4 1.9 89 8 84 305 13 5.6 19 -19.2 02/01/2006 11:50:00 3.2 0.7 5.3 1.5 2.6 0.6 3.8 1.1 84 10 79 305 12.4 5.2 20.4 -19 02/01/2006 12:00:00 3.4 0.5 4.6 1.9 2.8 0.5 3.8 1.1 78 7 83 305 13.8 5.4 20.1 -18.4 02/01/2006 12:10:00 3.3 0.3 4.6 2.3 2.8 0.3 3.8 2.3 79 7 87 305 13.2 6.7 22.5 -12.9 02/01/2006 12:20:00 3.2 0.4 4.2 2.3 2.7 0.4 3.8 1.9 82 8 79 305 14.9 6.4 22.2 -11.5 02/01/2006 12:30:00 3 0.4 4.2 1.5 2.5 0.4 3.4 1.1 78 8 82 305 15.8 5.6 22.8 -10.9 02/01/2006 12:40:00 2.4 0.8 4.2 0.4 1.8 0.8 3.4 0.4 84 23 74 305 14 3.5 19.6 -7.7 02/01/2006 12:50:00 1 0.8 4.2 0.4 0.7 0.6 3 0.4 118 72 97 305 12.4 5.4 20.1 -16.9 02/01/2006 13:00:00 2.8 0.9 4.6 0.4 2.2 1 4.2 0.4 90 17 90 305 13 6.2 21.6 -16 02/01/2006 13:10:00 3.9 0.4 4.9 2.6 3.6 0.5 4.9 1.9 110 7 105 305 12.6 7.6 20.4 -15.8 02/01/2006 13:20:00 3.8 0.4 4.9 3 3.4 0.4 4.6 2.3 109 6 111 305 11.3 4.4 16.7 -15.4 02/01/2006 13:30:00 3.9 0.5 4.9 2.6 3.5 0.5 4.6 2.3 108 6 109 305 14.1 5.6 21.3 -8.2 02/01/2006 13:40:00 4.2 0.4 5.3 3 3.7 0.5 4.9 2.3 103 6 106 305 14.4 6.4 20.4 -15 02/01/2006 13:50:00 4.9 0.5 5.7 3.4 4.5 0.5 5.7 3 108 4 111 305 14.1 6.4 21.6 -14.3 02/01/2006 14:00:00 5.2 0.4 6.1 4.2 4.9 0.4 5.7 3.8 108 4 106 305 13.2 8.3 23.1 -6.9 02/01/2006 14:10:00 5.2 0.4 6.1 4.2 5 0.4 5.7 4.2 110 3 108 305 15.8 6.7 22.2 -8.8 02/01/2006 14:20:00 5.1 0.4 6.1 4.2 4.9 0.4 6.1 3.8 111 3 110 305 15.1 6.7 22.5 -13.3 02/01/2006 14:30:00 5.2 0.4 6.1 3.8 5 0.4 6.1 3.8 115 4 116 305 15.7 5.4 24 -12.9 02/01/2006 14:40:00 4.9 0.3 5.7 4.2 4.8 0.3 5.7 3.8 120 3 117 305 17.4 5.6 24 -12.5 02/01/2006 14:50:00 5.1 0.3 5.7 4.2 5.1 0.3 5.7 4.2 120 4 114 305 18.6 4.7 25.5 -4 02/01/2006 15:00:00 5.1 0.3 5.7 4.2 5.1 0.3 5.7 4.2 119 3 114 305 15.8 4.7 22.2 -5.3 02/01/2006 15:10:00 5.2 0.3 5.7 4.2 5 0.3 6.1 4.2 119 3 124 305 20.9 4.7 27.6 -3.8 02/01/2006 15:20:00 4.9 0.3 5.7 4.2 4.6 0.3 5.3 3.8 116 3 116 305 20.5 5.6 27.9 -1.3 02/01/2006 15:30:00 4.7 0.3 5.3 3.8 4.6 0.3 5.3 3.8 116 3 115 305 20.7 5.9 26.4 -12.3 02/01/2006 15:40:00 4.8 0.4 5.7 3.8 4.6 0.4 5.7 3.8 117 2 119 305 19.3 6.4 27.9 -2.4 02/01/2006 15:50:00 5.1 0.3 5.7 4.2 4.9 0.3 5.3 4.2 114 2 112 305 21.4 5.9 27.3 0.1 02/01/2006 16:00:00 4.7 0.4 5.3 3.4 4.5 0.3 5.3 3.8 113 5 116 305 21.2 5.4 28.8 -2.7 02/01/2006 16:10:00 4.3 0.4 5.7 3.4 4.1 0.4 5.3 3 106 7 98 305 19.7 4.5 25.5 -2 02/01/2006 16:20:00 3.9 0.4 5.3 2.6 3.8 0.4 4.9 2.6 106 9 101 305 21.2 5.6 28.2 -1.3 02/01/2006 16:30:00 3.6 0.5 4.9 1.9 3.4 0.4 4.6 2.3 102 8 101 305 22.5 3.1 27.3 -1.3 02/01/2006 16:40:00 3.4 0.6 5.3 1.9 3 0.5 4.2 1.9 97 10 94 305 21.4 3.4 27.3 2.5 02/01/2006 16:50:00 2.9 0.4 4.2 1.5 2.6 0.5 3.4 1.1 89 10 94 305 22.3 4 28.5 -1.1 02/01/2006 17:00:00 2.6 0.4 3.4 1.1 2.2 0.4 3.4 1.1 84 12 80 305 23.8 3.4 29.8 -1.8 02/01/2006 17:10:00 2.5 0.5 3.8 1.1 2.1 0.4 3 0.7 80 11 98 305 24 3.7 28.8 -0.4 02/01/2006 17:20:00 2.2 0.6 3.4 0.7 1.9 0.6 3 0.7 71 17 82 305 23.7 3.7 29.5 -0.4 02/01/2006 17:30:00 2.6 0.4 3.4 1.5 2.2 0.4 3 1.1 80 7 94 305 22.7 3.2 27.9 -0.6 02/01/2006 17:40:00 2.5 0.4 3.4 1.5 2.2 0.4 3 1.1 79 7 72 305 22.8 3.8 27.6 0.1 02/01/2006 17:50:00 2.3 0.4 3.8 1.1 2 0.4 3.4 1.1 79 9 85 305 22.8 3.1 29.8 0.3 02/01/2006 18:00:00 2.3 0.6 3.8 0.7 2 0.6 3.4 0.7 65 23 68 305 25.6 4.4 29.5 0.6 02/01/2006 18:10:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 12 13 7 305 24.9 5.2 31.4 -0.4 02/01/2006 18:20:00 1.3 0.4 2.3 0.4 1.1 0.4 1.9 0.4 34 12 37 305 25.9 5 33.3 0.3 02/01/2006 18:30:00 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 40 11 53 305 25.4 3.7 32.6 2 02/01/2006 18:40:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 33 0 33 305 24.6 6.2 33.3 -3.6 02/01/2006 18:50:00 0.9 0.2 1.5 0.4 0.8 0.2 1.1 0.4 33 0 33 305 23.9 5.2 30.7 -1.1 02/01/2006 19:00:00 0.7 0.3 1.5 0.4 0.6 0.2 1.1 0.4 33 0 33 305 24 5 30.4 -1.1 02/01/2006 19:10:00 0.9 0.2 1.5 0.4 0.8 0.2 1.1 0.4 36 8 33 305 21.8 5 30.1 0.6 02/01/2006 19:20:00 0.9 0.2 1.5 0.4 0.8 0.3 1.5 0.4 40 8 36 305 24.2 4.2 30.1 1 02/01/2006 19:30:00 1.8 0.8 4.9 0.4 1.5 0.7 4.6 0.4 30 12 21 305 23.8 5 30.4 -1.3 02/01/2006 19:40:00 2.3 0.5 3.4 1.1 2.2 0.6 3.4 0.7 34 17 21 305 24.3 3.7 30.4 -1.3 02/01/2006 19:50:00 5 1.2 6.8 2.3 4.7 1.3 7.2 1.5 23 11 17 305 25.5 3.8 31.7 -1.5 02/01/2006 20:00:00 6.4 0.6 7.6 4.9 6.2 0.6 7.6 4.6 27 7 18 305 25.2 5.4 32.6 -1.3 02/01/2006 20:10:00 6.4 0.5 7.6 4.6 6.2 0.5 7.6 4.6 26 5 27 305 25.7 4.5 32.3 4.2 02/01/2006 20:20:00 6.9 0.7 8.4 4.9 6.7 0.7 8.8 4.9 26 5 27 305 24.5 5.4 31.7 -1.3 02/01/2006 20:30:00 7.5 0.6 8.8 5.3 7.4 0.7 9.1 5.7 25 4 24 305 25.7 5 33.3 -0.4 02/01/2006 20:40:00 7.9 0.7 9.1 6.1 7.7 0.7 9.1 5.7 25 4 26 305 26.3 4.5 31.7 2.5 02/01/2006 20:50:00 7.4 0.7 9.1 5.7 7.2 0.8 9.1 5.7 26 5 30 305 26 4.7 32 -0.6 02/01/2006 21:00:00 7.4 0.8 9.1 5.3 7.1 0.7 8.4 5.3 28 6 27 305 21.8 1.6 27.3 15.3 02/01/2006 21:10:00 7.6 0.7 8.8 5.7 7.5 0.7 9.1 5.3 30 5 29 305 21.4 0.3 22.5 19.9 02/01/2006 21:20:00 7.6 1 9.1 5.3 7.4 1 9.5 4.9 27 5 28 305 21.1 0.4 22.2 19.6 02/01/2006 21:30:00 7.3 1 9.1 4.9 7 1 9.5 4.9 29 5 30 305 21.7 1.1 31.4 20.7 02/01/2006 21:40:00 7.5 0.7 9.1 5.3 7.4 0.7 9.1 5.3 30 5 40 305 24.9 4.4 31.7 10.2 02/01/2006 21:50:00 6.2 0.6 7.6 4.6 6 0.6 7.6 4.6 34 10 21 305 24.6 4 31 -0.6 02/01/2006 22:00:00 6.1 0.5 7.6 4.9 6 0.6 8 4.6 44 5 39 305 25.5 2.7 33 9.7 02/01/2006 22:10:00 6.1 0.6 7.2 4.9 6 0.6 7.2 4.6 44 5 41 305 25.8 5.4 32.6 -7.7 02/01/2006 22:20:00 5.9 0.6 7.6 4.6 5.7 0.7 7.6 4.2 42 5 45 305 26.6 4.7 32.6 4.7 02/01/2006 22:30:00 6.5 0.5 8 5.3 6.3 0.6 8 4.6 44 5 42 305 26 4 31.4 3.9 02/01/2006 22:40:00 7 0.6 8.4 5.3 6.8 0.6 8 5.3 47 4 41 305 24.3 4.2 29.5 3.7 02/01/2006 22:50:00 7.1 0.5 8 5.7 6.9 0.5 8 5.3 47 5 50 305 16.3 7 28.2 -5.6 02/01/2006 23:00:00 7 0.5 8.4 5.7 6.9 0.6 8 5.7 46 4 48 305 9 0.5 10.5 7.7 02/01/2006 23:10:00 7.1 0.5 8.4 5.7 7 0.6 8.4 5.3 48 5 53 305 9.9 1.8 13.2 -8.2 02/01/2006 23:20:00 7.2 0.5 8.4 5.7 7 0.6 8 5.7 49 4 48 305 11.5 7 26.7 -11.3 02/01/2006 23:30:00 6.7 0.5 8 5.3 6.6 0.6 8.4 4.9 49 4 48 305 22 5.9 26.4 -5.6 02/01/2006 23:40:00 6.6 0.5 8 5.3 6.5 0.5 8 5.3 50 4 52 305 19.3 5.9 25.2 2.2 02/01/2006 23:50:00 6.4 0.5 7.6 4.9 6.3 0.5 7.6 4.9 51 5 53 305 18.3 6.4 23.7 -12.5 02/02/2006 00:00:00 6 0.5 7.2 4.6 5.8 0.5 7.2 4.6 48 6 37 305 16.5 9.1 27.3 -14.1 02/02/2006 00:10:00 6.2 0.6 7.6 4.9 6.1 0.6 8 4.6 45 5 51 305 18.8 7.3 27.3 2 02/02/2006 00:20:00 6.7 0.6 8 4.9 6.5 0.7 8 4.9 39 6 44 305 20 6.7 27.6 5.6 02/02/2006 00:30:00 7.1 0.7 8.4 4.9 6.9 0.7 8.4 4.6 39 6 38 305 21.4 4.4 27.6 5.6 02/02/2006 00:40:00 7.1 0.7 8.8 5.3 7 0.7 8.8 5.3 40 5 46 305 19.1 7 27.3 4.7 02/02/2006 00:50:00 7.5 0.6 9.1 5.3 7.3 0.7 8.8 4.9 40 5 35 305 20 7.3 29.8 1.5 02/02/2006 01:00:00 6.9 0.6 8.8 5.3 6.7 0.7 8.4 5.3 37 6 42 305 18.8 6.2 25.8 3.4 02/02/2006 01:10:00 7.1 0.7 8.4 4.6 7 0.7 8.4 5.3 34 8 39 305 16.9 5.4 24.3 2.5 02/02/2006 01:20:00 7.3 0.5 8.8 6.1 7.2 0.6 8.8 5.7 27 4 29 305 17.5 7.3 31.7 -4.7 02/02/2006 01:30:00 6.3 0.6 7.6 4.9 6.1 0.6 8 4.6 29 7 28 305 20.8 6.7 31 5.2 02/02/2006 01:40:00 6 0.8 8 3.8 5.8 0.7 7.6 4.2 31 6 27 305 20.7 5.9 30.4 5.4 02/02/2006 01:50:00 5.9 0.6 6.8 4.2 5.7 0.6 7.2 4.2 35 5 33 305 21.7 5.2 29.8 -10.4 02/02/2006 02:00:00 5.3 0.6 6.8 4.2 5 0.6 6.5 3.8 33 6 28 305 19.9 5.4 31 4.7 02/02/2006 02:10:00 5.6 0.8 6.8 3.4 5.4 0.9 6.8 3.4 30 9 37 305 21.2 5 29.8 4.2 02/02/2006 02:20:00 6.3 0.4 7.2 5.3 6.1 0.5 7.2 4.6 23 5 22 305 19.5 3.7 28.5 -2.9 02/02/2006 02:30:00 6.2 0.8 7.6 3.8 6 0.8 8 3.8 28 6 31 305 21.7 4 28.5 5.4 02/02/2006 02:40:00 6.6 0.6 8 4.9 6.4 0.6 8.4 4.9 17 5 25 305 19.7 5.6 27 4.4 02/02/2006 02:50:00 6.7 0.7 8 4.9 6.6 0.8 8.4 4.6 15 4 12 305 21 5 27.9 3.7 02/02/2006 03:00:00 6.8 0.7 8 4.9 6.7 0.7 8 4.9 13 4 12 305 20.4 5.2 28.2 5.2 02/02/2006 03:10:00 7 0.7 8.4 4.9 7 0.7 8.4 4.9 16 4 15 305 19.4 5.2 29.2 4.7 02/02/2006 03:20:00 6.8 0.6 8 4.9 6.7 0.7 8.4 4.6 12 4 18 305 18.7 4.4 24.3 4.2 02/02/2006 03:30:00 6.6 0.6 8 4.9 6.5 0.7 8 4.9 13 6 8 305 17.8 5.6 24.9 4.2 02/02/2006 03:40:00 7.2 0.5 8.4 5.7 7.1 0.5 8.4 5.3 12 3 12 305 20.3 2.3 24.3 4.4 02/02/2006 03:50:00 7.3 0.5 8.4 5.3 7.3 0.6 8.4 5.7 11 3 13 305 21.5 1 24.6 18.1 02/02/2006 04:00:00 7.2 0.6 8.4 5.3 7 0.7 8.8 5.3 11 4 13 305 21.3 2.6 23.1 4.7 02/02/2006 04:10:00 7.5 0.7 9.1 5.3 7.4 0.7 9.1 5.3 12 4 9 305 21.4 1.8 23.4 4.4 02/02/2006 04:20:00 6.3 0.7 8 4.6 6.1 0.7 8 4.6 14 6 17 305 17.3 6.4 22.5 4.2 02/02/2006 04:30:00 6.2 0.8 8.4 4.6 6.1 0.9 8.4 4.2 11 6 7 305 16.4 7.6 25.5 4.2 02/02/2006 04:40:00 6 0.8 8.4 3.8 5.9 0.9 8.8 3.8 13 6 9 305 18.8 5.6 24.9 4.2 02/02/2006 04:50:00 6.1 0.8 8.4 4.6 5.9 0.8 8.4 4.6 15 8 27 305 18.1 5.9 23.4 4.4 02/02/2006 05:00:00 6.8 0.8 8 4.6 6.6 0.8 8.4 4.2 32 10 19 305 12.6 8 24.6 4.7 02/02/2006 05:10:00 6.4 0.6 8.4 4.9 6.3 0.7 8.4 4.6 38 7 49 305 20.5 5.4 27 4.4 02/02/2006 05:20:00 7.2 0.7 8.8 4.9 7.1 0.8 8.4 4.9 40 5 41 305 19.3 5.2 27.6 3.7 02/02/2006 05:30:00 7.1 0.5 8.8 5.3 7 0.6 8.8 5.7 39 6 39 305 20.2 4.2 27.6 6.1 02/02/2006 05:40:00 6.9 0.7 8.4 4.9 6.8 0.8 8.8 5.3 40 5 42 305 17.2 6.2 27.3 3.9 02/02/2006 05:50:00 7.3 0.7 8.8 4.9 7.2 0.8 8.8 4.9 42 6 31 305 21.3 4.7 29.8 3.7 02/02/2006 06:00:00 7.8 0.6 8.8 6.1 7.7 0.6 9.1 6.1 47 6 41 305 24.5 3.7 29.8 3.2 02/02/2006 06:10:00 7.1 1.1 9.5 5.3 6.9 1.1 9.1 4.2 55 5 57 305 22 4.2 28.5 3.2 02/02/2006 06:20:00 7.2 0.6 8.8 5.3 7.1 0.7 8.8 4.9 50 6 54 305 22.8 3.8 28.8 2.7 02/02/2006 06:30:00 7.5 0.6 8.8 5.7 7.4 0.7 8.8 4.9 46 6 52 305 26 2.3 28.8 16.2 02/02/2006 06:40:00 7.4 0.7 8.8 5.3 7.3 0.8 8.8 5.3 51 6 51 305 22 4.7 29.5 2.5 02/02/2006 06:50:00 7.5 0.7 9.1 5.7 7.4 0.8 9.5 5.3 45 5 37 305 20.7 7 29.2 2.7 02/02/2006 07:00:00 7.8 0.7 9.1 5.7 7.7 0.7 9.5 5.3 45 6 47 305 20.6 4.7 25.8 2.2 02/02/2006 07:10:00 7.3 1 9.1 4.6 7.2 1.1 9.5 4.6 50 7 48 305 21.4 4.4 26.7 2.5 02/02/2006 07:20:00 7.5 0.9 9.1 5.3 7.3 0.9 9.1 4.9 49 7 59 305 19 6.2 29.2 2.2 02/02/2006 07:30:00 7.3 0.7 8.4 4.9 7.2 0.7 8.8 5.3 49 5 48 305 19.1 5.2 27.3 2.2 02/02/2006 07:40:00 7.4 0.8 8.8 4.6 7.2 0.9 9.1 4.6 46 7 48 305 22.4 3.1 27.3 10.2 02/02/2006 07:50:00 7.8 0.6 9.5 6.1 7.7 0.6 9.5 6.1 48 4 48 305 18.2 3.7 26.7 3.4 02/02/2006 08:00:00 7.6 0.9 9.5 5.3 7.4 0.9 9.5 5.3 47 5 48 305 17.6 2.9 24.9 6.1 02/02/2006 08:10:00 7.8 0.7 9.5 6.1 7.7 0.8 9.1 5.7 47 6 46 305 20.6 3.8 26.7 1.5 02/02/2006 08:20:00 6.9 0.6 8.4 4.9 6.8 0.7 8.4 4.9 47 7 56 305 20.9 3.5 26.4 11 02/02/2006 08:30:00 7.4 0.8 9.1 4.9 7.4 0.9 9.1 4.6 40 6 30 305 21.4 3.4 26.4 1 02/02/2006 08:40:00 7.1 0.9 8.4 4.9 6.9 0.9 8.8 4.6 38 5 27 305 21.2 3.1 27 13.7 02/02/2006 08:50:00 7.9 0.5 9.1 6.5 7.9 0.6 9.1 6.1 40 4 40 305 20.1 3.4 26.4 6.4 02/02/2006 09:00:00 7.3 0.8 8.8 5.3 7.2 0.8 8.8 4.9 42 7 44 305 19.4 3.7 27 6.4 02/02/2006 09:10:00 7.5 0.8 9.9 5.3 7.4 0.9 9.1 5.3 40 7 37 305 20.4 3.4 25.5 3.4 02/02/2006 09:20:00 8.2 0.6 9.9 5.7 8.3 0.8 9.9 6.1 34 4 37 305 19.3 4.2 26.4 3.4 02/02/2006 09:30:00 6.8 0.8 8.8 5.3 6.7 0.8 8.4 4.6 46 7 42 305 15.8 4 22.2 -1.5 02/02/2006 09:40:00 7.4 0.7 8.8 5.7 7.4 0.7 8.8 5.3 48 5 46 305 16.9 3.5 23.1 1.5 02/02/2006 09:50:00 7.5 1 9.1 5.3 7.5 1.1 9.5 4.9 38 6 34 305 17.2 5.6 26.4 2.7 02/02/2006 10:00:00 8.1 0.7 9.1 5.7 8 0.8 9.5 5.7 44 5 48 305 15.2 5 21.9 2.9 02/02/2006 10:10:00 7.7 0.7 8.8 5.7 7.6 0.8 9.5 5.3 40 6 49 305 14.9 5.2 21 -1.1 02/02/2006 10:20:00 8 0.8 9.5 5.3 7.8 0.9 9.9 5.3 39 7 35 305 17.6 3.8 23.7 3.2 02/02/2006 10:30:00 7.6 0.8 9.5 5.7 7.5 0.9 9.1 5.3 50 4 52 305 19.1 3.2 24.3 5.6 02/02/2006 10:40:00 6.7 0.7 8.4 4.9 6.6 0.8 8.4 4.6 44 7 52 305 15.8 3.7 22.8 2 02/02/2006 10:50:00 7.6 0.6 8.8 6.1 7.4 0.7 9.1 5.3 35 5 34 305 15.8 2.9 22.5 4.2 02/02/2006 11:00:00 7.4 0.8 9.5 5.3 7.4 1 9.5 4.9 43 7 39 305 16 4 24.3 2.5 02/02/2006 11:10:00 7.8 0.6 9.1 6.1 7.8 0.7 9.1 6.1 41 7 44 305 18.6 4 24.6 2.5 02/02/2006 11:20:00 7.5 0.7 9.5 5.3 7.4 0.7 9.5 5.7 40 7 38 305 17.3 3.5 23.1 1.3 02/02/2006 11:30:00 7.1 0.8 8.8 5.3 7 0.9 8.8 4.9 41 11 49 305 16.7 2.5 21.9 9.7 02/02/2006 11:40:00 6.9 0.7 8.8 5.3 6.8 0.8 8.8 4.9 48 5 51 305 14.3 2.7 20.1 2.2 02/02/2006 11:50:00 6.9 0.9 8.8 4.9 6.8 1 8.8 4.6 48 5 50 305 16 3.5 21.6 2.9 02/02/2006 12:00:00 7.2 0.7 8.8 5.3 7.1 0.8 9.1 4.9 48 6 53 305 16 4 23.4 1.7 02/02/2006 12:10:00 7.9 0.7 9.5 6.1 7.9 0.8 9.1 5.7 48 5 48 305 17.3 3.2 22.2 7.4 02/02/2006 12:20:00 8 0.8 10.3 6.1 8 1 10.3 5.7 40 7 46 305 15.3 3.5 20.7 -0.4 02/02/2006 12:30:00 8.1 0.6 9.5 6.5 8 0.7 9.9 5.7 33 5 37 305 14.6 3.4 21.3 1.5 02/02/2006 12:40:00 8.2 0.6 9.9 6.5 8.2 0.8 9.9 6.1 35 5 34 305 12.8 3.4 19.6 1.5 02/02/2006 12:50:00 8.1 0.9 10.7 6.1 8 1 10.7 5.7 36 7 36 305 16.8 3.8 21.9 -2.2 02/02/2006 13:00:00 9.2 0.7 10.7 6.8 9.1 0.8 11.5 6.8 36 7 42 305 14.8 4 21 0.6 02/02/2006 13:10:00 9.1 0.9 11.5 6.1 9.2 1.1 11.8 6.1 38 6 38 305 18.4 4 24.6 0.1 02/02/2006 13:20:00 8.4 0.8 10.3 6.5 8.5 0.9 10.3 6.1 37 6 44 305 17.1 4.2 22.8 -0.4 02/02/2006 13:30:00 8.7 0.6 10.3 7.2 8.7 0.7 10.7 6.5 33 5 37 305 17.5 4.2 23.4 1.3 02/02/2006 13:40:00 8.4 0.8 10.3 6.1 8.4 0.9 10.3 6.1 29 6 27 305 15.3 4.4 24.6 0.1 02/02/2006 13:50:00 8.6 0.6 10.3 6.8 8.6 0.8 10.3 6.5 37 6 41 305 14.4 4.2 22.8 0.6 02/02/2006 14:00:00 8.2 0.7 10.3 6.5 8.2 0.8 10.3 6.1 31 8 43 305 17.8 4.2 24.3 -2.7 02/02/2006 14:10:00 8.6 0.9 10.7 5.3 8.6 0.8 10.7 5.7 41 5 45 305 16.1 5.6 24.6 1.3 02/02/2006 14:20:00 8.2 0.9 10.3 6.1 8.1 1.1 10.3 6.1 37 6 35 305 16.2 4.4 23.1 1 02/02/2006 14:30:00 9.1 0.7 11.1 7.2 9.2 0.9 11.1 6.5 40 6 42 305 16.5 5.2 24.6 1 02/02/2006 14:40:00 9.4 0.8 11.5 6.8 9.4 1 11.5 6.8 37 7 29 305 16.5 4.5 24.9 0.6 02/02/2006 14:50:00 8.9 0.8 10.7 6.8 8.8 0.8 11.1 6.8 30 5 32 305 17.6 3.8 24 0.6 02/02/2006 15:00:00 8.9 0.9 11.1 6.8 8.7 1 11.8 6.8 31 6 32 305 16.9 4.4 23.7 0.1 02/02/2006 15:10:00 9.6 0.8 11.8 7.2 9.3 0.8 11.8 6.8 29 6 32 305 17.1 3.5 23.1 -0.6 02/02/2006 15:20:00 9.3 0.9 11.1 6.5 9.4 1 11.1 6.1 36 6 46 305 16.2 4.2 22.5 -0.4 02/02/2006 15:30:00 9.3 1 12.6 6.8 9.2 1.2 11.8 6.5 33 8 20 305 16.7 3.1 21.9 0.1 02/02/2006 15:40:00 9.3 0.9 11.5 6.8 9.2 1 11.5 7.2 33 7 50 305 15.9 4.5 21.3 -0.6 02/02/2006 15:50:00 9.1 0.9 11.5 7.2 9.1 1 12.2 6.8 36 7 37 305 16.1 3.7 22.8 -0.8 02/02/2006 16:00:00 9.6 0.7 11.5 7.2 9.6 1 11.5 6.8 36 7 31 305 14 3.4 21.9 -1.1 02/02/2006 16:10:00 10 0.7 12.2 8 9.8 0.9 12.2 7.6 37 5 49 305 13.7 4 20.1 -1.1 02/02/2006 16:20:00 9.8 0.8 11.8 8 9.8 0.9 11.8 7.6 37 6 41 305 13.7 2.7 22.2 1.5 02/02/2006 16:30:00 10.5 0.8 12.6 8 10.4 1 13 8.4 34 5 44 305 12.8 2.9 20.1 -1.3 02/02/2006 16:40:00 10.1 0.9 12.2 7.6 10 1 12.2 7.2 31 6 33 305 12.6 3.5 21.3 -2 02/02/2006 16:50:00 9.8 0.8 11.8 7.2 9.5 0.9 11.8 7.6 33 7 36 305 13.3 5.4 22.8 -3.6 02/02/2006 17:00:00 9.8 1 12.2 7.2 9.5 1 12.2 7.2 31 7 27 305 16.2 5.2 23.4 -2.7 02/02/2006 17:10:00 10.1 0.9 12.2 7.2 9.9 1 12.2 6.8 33 8 35 305 17.2 3.2 24 1.3 02/02/2006 17:20:00 9.7 1 11.8 6.8 9.4 0.9 11.5 6.8 35 7 27 305 15.8 4 22.8 -3.1 02/02/2006 17:30:00 9.8 1 13 7.2 9.7 1 12.6 6.8 35 6 32 305 15.6 4.2 23.1 -4.7 02/02/2006 17:40:00 10.3 1 13 7.2 10.4 1.3 13.3 6.8 37 5 41 305 14 5 22.2 -4.9 02/02/2006 17:50:00 10.4 0.9 12.6 8 10.2 1 13 8 30 5 32 305 12.6 5.2 20.4 -7.9 02/02/2006 18:00:00 10.1 0.8 12.2 8 9.9 1 12.6 7.6 33 5 33 305 13.6 2.7 20.1 3.2 02/02/2006 18:10:00 10 0.8 12.2 7.6 9.7 1 13 7.6 31 6 19 305 16.3 2.3 21.9 9.2 02/02/2006 18:20:00 10.1 0.9 12.2 7.6 10.1 1 12.2 7.2 28 6 33 305 15 3.4 21 -8.2 02/02/2006 18:30:00 10 0.8 11.8 7.6 9.8 1 12.2 7.6 29 6 23 305 15.1 3.7 21.6 -8.2 02/02/2006 18:40:00 9.9 0.8 11.5 8 9.8 1 12.2 7.6 33 6 29 305 17.9 3.4 23.7 -6.7 02/02/2006 18:50:00 9.4 0.9 11.8 6.8 9.2 1 12.2 6.8 29 7 23 305 16.3 3.4 21.9 0.3 02/02/2006 19:00:00 10.5 1 13 8 10.3 1.1 13 8 27 5 26 305 15.6 3.4 21 2.2 02/02/2006 19:10:00 9.9 0.9 12.2 7.2 9.7 1 11.8 7.2 25 6 21 305 16.4 3.8 21.3 -8.8 02/02/2006 19:20:00 10.3 0.9 12.2 7.6 10 1.1 13 7.2 29 5 27 305 16 3.2 20.7 4.4 02/02/2006 19:30:00 10.5 1.1 14.1 8 10.1 1.1 13 7.6 35 6 39 305 14.7 4 21.3 -7.3 02/02/2006 19:40:00 10.4 1.1 13 8 10 1 12.6 7.2 31 5 33 305 15.3 3.7 21.3 -3.3 02/02/2006 19:50:00 11 0.7 13 8.8 10.7 1 12.6 8.8 28 6 27 305 16.3 4 21.6 -7.1 02/02/2006 20:00:00 10.8 0.8 13 9.1 10.7 1 13.3 8.4 34 5 40 305 14.9 4.2 21 -8.4 02/02/2006 20:10:00 10.1 0.8 12.6 7.6 9.9 1 13 7.6 33 7 42 305 14.9 4.2 20.1 -8.4 02/02/2006 20:20:00 9.4 0.8 11.5 6.1 9.4 0.9 11.5 6.8 31 8 40 305 16.6 3.5 21.9 -8.4 02/02/2006 20:30:00 10.1 0.9 12.2 6.8 9.8 0.9 12.2 7.2 34 7 33 305 14.1 5 21.6 -8.2 02/02/2006 20:40:00 9.4 1 11.8 6.8 9.5 1.2 11.8 6.5 30 7 39 305 15.8 3.5 21.3 -8.4 02/02/2006 20:50:00 10.1 1 12.6 7.6 9.9 1.1 13 7.2 33 6 32 305 12.4 5.6 21.3 -7.9 02/02/2006 21:00:00 9.8 0.8 12.2 6.8 9.8 1 12.2 6.8 22 6 27 305 14.6 4.2 21.3 -7.7 02/02/2006 21:10:00 9.9 1 12.6 6.8 9.6 1 12.6 6.8 22 6 9 305 17 3.7 22.2 -6 02/02/2006 21:20:00 10.4 0.9 12.6 7.6 10.2 1 12.6 7.6 19 5 21 305 15.6 3.8 22.2 -5.8 02/02/2006 21:30:00 10.4 1 12.6 7.6 10.2 1.1 13 7.6 25 6 20 305 16.8 5 24 -5.6 02/02/2006 21:40:00 9.5 1.2 12.2 6.8 9.7 1.4 12.6 6.8 28 7 27 305 17.9 3.2 22.2 4.7 02/02/2006 21:50:00 9.9 1.3 12.6 6.8 9.8 1.3 13 6.5 25 7 30 305 15.7 4.4 21.6 -6 02/02/2006 22:00:00 10.9 1 13 7.6 10.4 1 13 8 26 7 17 305 13 4.7 20.7 -7.3 02/02/2006 22:10:00 11.1 1.1 13.7 8 10.9 1.2 13.7 7.6 23 5 23 305 12.2 4 19 -7.3 02/02/2006 22:20:00 10.1 1.2 13.3 7.2 9.9 1.2 13 7.2 28 6 39 305 9.8 4.4 17.9 -8.2 02/02/2006 22:30:00 11 1.1 13.3 7.6 10.6 1.1 13.3 7.6 24 7 27 305 13.5 5 21.6 -7.7 02/02/2006 22:40:00 11.3 1.1 13.7 8.4 11.2 1.2 14.1 8.4 21 5 23 305 16.4 3.7 21.3 -8.2 02/02/2006 22:50:00 10.6 0.9 13.3 8 10.3 1 12.6 8 23 6 14 305 15.3 3.8 20.7 -7.7 02/02/2006 23:00:00 10.8 1 13.3 8 10.5 1 13 8 24 6 15 305 14.9 3.8 20.1 -7.5 02/02/2006 23:10:00 10.7 1.3 13.7 7.6 10.2 1.2 13 7.6 19 5 17 305 14.9 3.8 20.4 -7.3 02/02/2006 23:20:00 11.4 1.4 14.1 6.8 11.3 1.5 14.1 7.2 19 6 16 305 13.1 4.2 19.6 -7.1 02/02/2006 23:30:00 9.4 1 11.8 6.8 9.2 1 11.8 6.8 15 4 18 305 13.9 4.4 20.7 -7.7 02/02/2006 23:40:00 8.7 1.1 11.5 5.7 8.6 1.1 11.8 6.1 18 6 17 305 11.8 4.7 18.4 -8.8 02/02/2006 23:50:00 11 0.7 13 9.1 11 1 13 8 19 5 21 305 12.9 5 20.1 -8.8 02/03/2006 00:00:00 11.2 0.9 13.3 8.8 10.9 1 13.3 8 19 5 26 305 13 4 18.7 -9.2 02/03/2006 00:10:00 10.1 1.1 13.3 7.6 9.9 1.2 12.6 7.2 21 8 21 305 10.8 4.7 17.9 -10 02/03/2006 00:20:00 9.4 1 12.2 6.5 9.1 1 11.8 6.5 17 6 12 305 11.4 3.8 17.9 -7.7 02/03/2006 00:30:00 10.8 1.2 14.1 8 10.5 1.2 13.7 8 18 6 21 305 12.2 3.8 18.7 -7.1 02/03/2006 00:40:00 10.6 1.4 14.1 7.2 10.4 1.3 14.1 6.8 20 6 21 305 13.5 4.2 19.6 -6.7 02/03/2006 00:50:00 12 1.1 14.1 9.1 11.7 1.2 14.9 8 22 6 21 305 11.6 4 16.2 -6.7 02/03/2006 01:00:00 11.8 1.2 14.5 8 11.3 1.3 14.5 8.4 24 6 27 305 12.7 3.1 16.7 -4.7 02/03/2006 01:10:00 10.6 1 13.3 7.6 10.4 1 13 8 25 6 30 305 11.8 3.5 16.2 -8.2 02/03/2006 01:20:00 11.3 1 14.1 8.8 10.7 1 13 7.2 22 5 29 305 9.8 4.4 15.1 -11.5 02/03/2006 01:30:00 11.1 1 13.3 8 10.7 1 13.3 8 24 5 19 305 10.1 5 16.7 -8.2 02/03/2006 01:40:00 10.2 1.3 13.7 6.8 10 1.2 13.3 6.5 24 6 25 305 8.2 4.2 15.1 -8.8 02/03/2006 01:50:00 10.9 1.2 14.1 7.6 10.9 1.2 14.1 8 24 5 24 305 9.3 3.4 14 -8.6 02/03/2006 02:00:00 9.8 1.1 12.6 7.6 9.7 1.1 12.2 6.8 19 6 22 305 9.8 3.5 14 -8.8 02/03/2006 02:10:00 10.4 1 13.3 8 10.2 1.1 13 8 20 6 21 305 10 3.2 15.3 0.3 02/03/2006 02:20:00 10.4 0.9 13.3 7.6 10.3 1 13.7 8.4 21 5 17 305 10 3.7 15.3 1 02/03/2006 02:30:00 10.2 0.8 12.2 8.4 10.2 1 13 6.8 18 5 25 305 10.3 4 15.6 -9 02/03/2006 02:40:00 10.4 1 12.6 7.6 10.2 1.1 13 8 20 5 26 305 10.4 3.4 15.3 -10.9 02/03/2006 02:50:00 10.3 0.8 12.2 8 10.2 1 12.2 7.6 22 5 16 305 11.3 2.9 15.3 -1.8 02/03/2006 03:00:00 9.8 1 12.2 6.5 9.8 1 12.2 6.5 24 5 21 305 10.9 2.3 14.5 -8.2 02/03/2006 03:10:00 9.6 0.7 11.5 8 9.5 0.8 11.5 7.6 23 5 30 305 9.5 3.5 14.5 -10.2 02/03/2006 03:20:00 8.6 0.8 10.7 6.1 8.5 1 11.1 5.7 17 5 15 305 10.3 1.5 14.5 3.4 02/03/2006 03:30:00 8.8 1 10.7 5.7 8.7 1 11.5 5.7 16 5 21 305 10 2 15.1 2.7 02/03/2006 03:40:00 7.2 1 10.7 5.3 7.2 1 10.3 5.3 15 7 23 305 11.8 2.6 15.6 2.2 02/03/2006 03:50:00 8.7 1.3 10.7 4.9 8.8 1.5 11.5 5.3 10 6 12 305 12.2 1.5 15.3 5.2 02/03/2006 04:00:00 8.7 0.8 10.3 6.5 8.7 1 10.7 6.5 7 5 5 305 12.4 1.8 16.5 3.4 02/03/2006 04:10:00 9 0.8 10.7 6.8 9.1 1 11.1 6.5 4 4 3 305 12.2 2.1 16.7 4.4 02/03/2006 04:20:00 8 0.9 10.3 5.7 7.9 1 10.3 5.7 7 7 18 305 10.9 4.5 17.9 -8.4 02/03/2006 04:30:00 8.8 0.7 10.3 6.8 8.8 0.9 10.7 6.1 4 5 3 305 10.4 3.7 16.7 2.7 02/03/2006 04:40:00 9.1 0.7 11.5 6.8 9.2 0.8 11.1 7.2 7 4 8 305 8.4 4 13.7 -9.8 02/03/2006 04:50:00 9 0.8 11.5 6.5 9 0.8 11.5 6.8 10 5 12 305 8.2 4.4 14.3 -10.4 02/03/2006 05:00:00 8.5 0.8 10.3 5.7 8.6 1 10.7 5.7 13 7 8 305 11.6 4 17.6 -2.2 02/03/2006 05:10:00 8.9 0.7 10.3 7.2 9 0.8 10.7 6.8 15 6 17 305 12.4 3.2 16.7 2.5 02/03/2006 05:20:00 8.7 0.8 11.1 6.5 8.6 1 11.1 6.5 16 5 8 305 11.9 3.5 15.6 -5.8 02/03/2006 05:30:00 8.3 0.7 9.5 6.5 8.2 0.7 9.5 6.1 19 4 22 305 7.9 6.2 13.7 -8.2 02/03/2006 05:40:00 8 0.8 9.9 5.7 8 0.8 9.9 5.3 18 5 13 305 3.5 5.4 12.1 -7.9 02/03/2006 05:50:00 8.4 0.7 9.9 6.5 8.3 0.8 10.3 6.1 18 5 25 305 4.4 4.2 12.1 -6.7 02/03/2006 06:00:00 8.3 0.7 9.9 6.1 8.3 0.8 9.9 6.1 17 4 14 305 5.5 5.2 14.5 -6.7 02/03/2006 06:10:00 7.9 0.7 9.5 5.7 7.9 0.7 9.5 5.7 14 4 11 305 8.2 5.4 16.7 -8.4 02/03/2006 06:20:00 7.6 0.8 9.1 5.3 7.5 0.9 9.1 5.3 14 5 9 305 8.4 5.4 16.5 -9.2 02/03/2006 06:30:00 7.8 0.9 9.5 5.3 7.8 1 9.9 4.6 9 4 12 305 9.1 5.2 16.5 -9.8 02/03/2006 06:40:00 7.4 0.9 9.1 5.3 7.3 0.9 9.1 5.3 15 6 13 305 6.1 5.9 16.2 -8.6 02/03/2006 06:50:00 7.6 0.6 9.5 6.1 7.6 0.7 9.1 5.7 15 6 20 305 8.1 5 16.7 -9.6 02/03/2006 07:00:00 7.2 1.1 9.1 4.6 7.2 1.2 9.5 4.6 14 5 15 305 8.1 4.4 15.6 -6.7 02/03/2006 07:10:00 7 0.8 8.4 4.9 6.8 0.8 8.8 4.9 18 5 23 305 9.2 4.5 17.6 -8.4 02/03/2006 07:20:00 7.2 0.8 8.8 4.9 7.1 0.8 8.8 4.9 12 5 11 305 9.6 4.4 16.7 -9.2 02/03/2006 07:30:00 6.7 0.8 8.8 4.9 6.7 0.9 9.1 4.9 12 8 9 305 6.8 5.6 14.3 -10.4 02/03/2006 07:40:00 7.2 1.1 9.1 4.2 7.2 1.1 9.1 4.2 21 5 22 305 6.8 4 12.9 -10.4 02/03/2006 07:50:00 7.4 0.7 9.1 4.9 7.2 0.8 8.8 4.9 20 5 20 305 8.5 3.4 15.6 -8.2 02/03/2006 08:00:00 7.2 1 8.8 5.3 7.1 1 9.1 4.9 19 6 23 305 8.2 3.8 15.3 -8.2 02/03/2006 08:10:00 7.4 0.7 8.8 5.3 7.3 0.8 8.8 4.6 20 6 27 305 10.8 2.8 16.5 3.4 02/03/2006 08:20:00 7.3 0.8 9.1 4.9 7.2 0.8 9.1 5.3 19 5 18 305 9.1 4 15.3 -8.4 02/03/2006 08:30:00 8 0.6 9.1 5.7 7.9 0.6 9.1 5.7 19 4 20 305 10.2 3.8 16.2 -8.8 02/03/2006 08:40:00 7.7 0.7 9.1 5.7 7.6 0.8 9.1 5.7 19 5 23 305 8.1 4 16.2 -7.5 02/03/2006 08:50:00 7.9 0.6 9.5 6.1 7.8 0.7 9.1 5.7 20 4 20 305 9.3 2.9 15.9 -1.8 02/03/2006 09:00:00 7.2 0.8 8.8 4.9 7 0.9 9.1 4.9 18 6 13 305 9.9 3.4 15.1 -7.1 02/03/2006 09:10:00 7.1 0.8 9.1 4.9 7.1 0.8 9.5 4.9 23 6 15 305 10.7 3.7 15.9 -7.3 02/03/2006 09:20:00 6.8 0.9 8.8 4.6 6.6 0.9 8.8 4.6 23 5 28 305 8.8 3.8 15.3 -8.6 02/03/2006 09:30:00 6.4 0.8 8 4.6 6.2 0.8 8 4.6 24 6 19 305 10.6 3.4 16.2 -6 02/03/2006 09:40:00 6.1 0.7 8 4.6 6 0.7 7.6 3.8 25 6 36 305 11 3.1 15.1 -7.3 02/03/2006 09:50:00 6.6 0.7 8 4.6 6.4 0.7 8 4.6 23 6 27 305 9.5 2.8 15.1 -7.7 02/03/2006 10:00:00 7.1 0.6 8 5.3 6.9 0.6 8.4 4.6 22 5 23 305 9.1 3.4 14.8 -6.2 02/03/2006 10:10:00 7.4 0.5 8.4 6.1 7.4 0.5 8.8 6.1 19 4 25 305 9.7 3.4 14.5 -6.4 02/03/2006 10:20:00 6.7 0.6 8 4.6 6.6 0.7 8 4.6 21 4 18 305 9.9 3.2 14.5 -6.2 02/03/2006 10:30:00 5.9 0.6 7.6 4.6 5.7 0.6 7.2 4.2 12 6 14 305 9.2 3.1 15.3 -5.3 02/03/2006 10:40:00 6.2 0.7 7.6 4.2 6.1 0.7 7.6 4.2 10 6 9 305 8.5 4.7 18.7 -6.9 02/03/2006 10:50:00 6.2 0.7 7.6 4.2 6.1 0.8 7.6 4.2 13 5 18 305 11.8 3.8 19 -5.6 02/03/2006 11:00:00 6.5 0.6 7.6 4.9 6.4 0.6 7.6 4.6 10 3 11 305 11.5 4 18.4 -4.7 02/03/2006 11:10:00 5.7 0.6 7.2 4.2 5.5 0.7 7.2 4.2 15 6 11 305 16.7 5.9 27.9 -3.8 02/03/2006 11:20:00 6.4 0.6 8 4.6 6.2 0.7 8 4.6 23 5 25 305 15.7 6.2 26.7 -5.6 02/03/2006 11:30:00 6.5 0.5 7.6 5.3 6.4 0.5 7.6 5.3 23 4 21 305 15.4 4.5 24.3 -4.9 02/03/2006 11:40:00 6.5 0.6 8 4.9 6.4 0.6 8 4.6 25 4 25 305 14.6 5 23.4 -5.6 02/03/2006 11:50:00 6.4 0.6 7.2 4.6 6.3 0.6 7.2 4.6 25 5 30 305 12.6 5.6 23.7 -4.2 02/03/2006 12:00:00 5.3 0.5 6.8 4.2 5.1 0.5 6.5 3.8 24 6 24 305 15 4.5 24 -4.7 02/03/2006 12:10:00 6.1 0.5 7.2 4.9 6 0.5 7.2 4.6 30 5 38 305 12.8 5.2 22.8 -5.3 02/03/2006 12:20:00 6.6 0.6 7.6 4.9 6.4 0.6 7.6 4.6 28 5 27 305 14.5 5.2 24 -1.1 02/03/2006 12:30:00 6.5 0.5 7.6 4.6 6.3 0.5 7.6 4.9 26 5 24 305 11.8 4.7 23.4 -6.9 02/03/2006 12:40:00 6.6 0.4 7.6 5.3 6.5 0.5 7.6 4.9 22 4 21 305 9 3.5 16.2 0.6 02/03/2006 12:50:00 6.6 0.4 7.6 5.3 6.6 0.4 7.2 5.3 21 3 22 305 8.7 3.5 16.2 -8.8 02/03/2006 13:00:00 6.1 0.5 7.2 4.9 5.9 0.5 6.8 4.6 26 6 23 305 7.2 5.4 15.6 -10.9 02/03/2006 13:10:00 5.6 0.5 6.8 4.2 5.4 0.5 6.8 3.8 36 7 34 305 9.4 4 15.6 -6.9 02/03/2006 13:20:00 5.9 0.6 7.2 4.6 5.7 0.7 7.2 4.2 39 6 47 305 9.3 4.5 17.3 -6 02/03/2006 13:30:00 5.6 0.7 7.2 4.2 5.4 0.7 7.2 3.8 36 5 36 305 8.9 5.2 16.7 -5.8 02/03/2006 13:40:00 6.7 0.6 8 5.3 6.6 0.6 8 4.9 35 5 36 305 8.3 5 16.5 -4.7 02/03/2006 13:50:00 6.4 0.7 8 4.2 6.4 0.8 8 4.6 40 5 41 305 10.1 4.7 17.3 -5.6 02/03/2006 14:00:00 6.1 0.5 7.2 4.6 6 0.5 7.2 4.6 40 7 42 305 11.6 3.4 16.7 -3.8 02/03/2006 14:10:00 6.1 0.6 7.2 4.2 5.9 0.5 6.8 4.6 47 7 52 305 11 3.8 16.7 -5.1 02/03/2006 14:20:00 5.3 0.6 6.5 3.4 5.1 0.7 6.8 3.4 32 6 33 305 11.2 4 17.6 -5.8 02/03/2006 14:30:00 5.7 0.5 6.8 4.6 5.5 0.6 6.8 3.8 44 8 25 305 11.9 4.5 19 -5.1 02/03/2006 14:40:00 5.1 0.8 6.8 3.4 5 0.8 6.8 3 43 7 42 305 13.2 3.5 19.3 -5.1 02/03/2006 14:50:00 5.6 0.6 7.2 3.8 5.5 0.6 7.2 3.8 29 6 32 305 12.4 3.8 20.4 -5.6 02/03/2006 15:00:00 6.2 0.6 7.6 4.6 6.1 0.6 7.2 4.9 36 8 29 305 14.4 3.7 19 -5.8 02/03/2006 15:10:00 5.7 0.6 7.2 4.2 5.6 0.6 6.8 4.2 39 6 37 305 14.1 4.4 20.7 -4.9 02/03/2006 15:20:00 5.7 0.5 6.8 3.8 5.6 0.5 7.2 4.2 31 6 29 305 14.5 4.7 20.4 -6.4 02/03/2006 15:30:00 5.3 0.6 6.8 3.8 5 0.6 6.8 3.4 36 8 54 305 12.8 5 19.9 -6.2 02/03/2006 15:40:00 5 0.6 6.8 3.4 4.8 0.7 6.8 3 43 8 38 305 13.8 3.8 19 -4.9 02/03/2006 15:50:00 5.2 0.6 7.2 3.8 5.1 0.7 7.2 3.4 42 9 44 305 13.2 4 19 -5.6 02/03/2006 16:00:00 4.6 0.6 6.1 3.4 4.4 0.6 6.1 3 50 7 51 305 13.9 4 19.9 -6 02/03/2006 16:10:00 4.8 0.4 5.7 3.8 4.7 0.5 5.7 3.4 54 6 44 305 14.3 4.4 19.9 -4.7 02/03/2006 16:20:00 4.9 0.4 6.1 3.8 4.8 0.5 5.7 3 49 7 48 305 14.8 4 21.3 -4.9 02/03/2006 16:30:00 5 0.4 5.7 3.8 4.9 0.4 5.7 3.8 48 4 45 305 13.6 4.7 21.3 -5.6 02/03/2006 16:40:00 4.7 0.4 5.7 3.8 4.6 0.5 5.7 3.4 50 5 52 305 13.6 4.4 20.1 -4.5 02/03/2006 16:50:00 4.5 0.6 5.7 3.4 4.3 0.6 5.7 3 53 6 56 305 14.1 3.8 20.1 -4.7 02/03/2006 17:00:00 4.4 0.5 5.7 3 4.3 0.5 5.3 2.6 47 6 48 305 15.2 4.4 31.4 1.5 02/03/2006 17:10:00 5.1 0.4 6.1 4.2 5 0.4 6.1 3.8 45 5 42 305 28.1 4.5 33.3 11.8 02/03/2006 17:20:00 5.1 0.5 6.1 3.8 4.9 0.6 6.1 3.4 46 5 49 305 26.2 5.2 33.3 10 02/03/2006 17:30:00 5.4 0.4 6.5 4.2 5.3 0.5 6.1 4.2 46 3 43 305 24.6 4.4 31 -4 02/03/2006 17:40:00 4.7 0.4 6.1 3.8 4.6 0.5 5.7 3.4 47 4 37 305 23.8 4.7 29.8 9.5 02/03/2006 17:50:00 5.1 0.6 6.1 3.4 5.1 0.7 6.1 3 45 4 44 305 24.5 4.2 29.8 8.7 02/03/2006 18:00:00 4.3 0.6 5.7 3 4.1 0.6 6.1 3 47 5 45 305 25 4.2 31.7 4.9 02/03/2006 18:10:00 4.9 0.6 6.1 3.4 4.8 0.7 6.1 3 49 4 55 305 25.5 4.5 32 -0.1 02/03/2006 18:20:00 5.3 0.3 6.1 4.6 5.2 0.4 6.1 4.2 41 6 51 305 24.9 4.2 31.7 3.9 02/03/2006 18:30:00 5.4 0.5 6.8 4.2 5.3 0.6 6.8 3.8 41 5 37 305 24.6 3.8 30.7 7.4 02/03/2006 18:40:00 5.3 0.6 6.5 3.8 5.1 0.7 6.5 3.8 40 5 39 305 24.5 3.7 30.1 7.2 02/03/2006 18:50:00 5.3 0.4 6.1 4.2 5.2 0.5 6.5 3.8 39 6 38 305 25 3.7 30.4 10.8 02/03/2006 19:00:00 5 0.5 6.5 3.8 4.7 0.5 6.1 3.8 37 6 38 305 23.7 4.4 29.2 8.9 02/03/2006 19:10:00 4.7 0.5 6.1 3.4 4.4 0.5 5.3 3 34 5 32 305 23.8 3.8 28.5 3.9 02/03/2006 19:20:00 5.3 0.5 6.5 3.8 5.1 0.5 6.5 3.4 30 5 35 305 22.7 4.5 29.5 3.9 02/03/2006 19:30:00 5.1 0.3 6.1 4.2 4.9 0.4 5.7 3.8 31 4 34 305 22.4 5.2 29.2 -11.7 02/03/2006 19:40:00 5.9 0.6 7.2 4.2 5.7 0.6 7.2 4.2 32 4 31 305 23 4 29.2 4.2 02/03/2006 19:50:00 5.4 0.5 6.5 4.2 5.2 0.5 6.5 4.2 36 5 36 305 22.2 4.5 28.2 -7.9 02/03/2006 20:00:00 4.9 0.5 6.5 3.4 4.7 0.5 6.5 3.8 27 6 31 305 23.4 4 29.8 4.4 02/03/2006 20:10:00 4.6 0.5 6.1 3.4 4.4 0.6 6.1 3 30 6 25 305 22.2 4.2 27.6 1.5 02/03/2006 20:20:00 5.5 0.5 6.8 4.2 5.3 0.6 6.8 4.2 33 5 26 305 21.9 5.2 29.2 -9.8 02/03/2006 20:30:00 5.4 0.6 6.8 3.8 5.2 0.5 6.8 3.8 35 6 39 305 22.9 4.4 28.2 4.7 02/03/2006 20:40:00 6 0.5 6.8 4.6 5.8 0.5 6.8 4.6 36 5 37 305 21.8 5.6 29.5 -2.4 02/03/2006 20:50:00 6.1 0.5 7.2 4.6 5.8 0.6 7.2 4.6 35 6 38 305 22.1 5.4 28.5 2 02/03/2006 21:00:00 6.2 0.5 7.2 4.6 6.1 0.6 7.6 4.2 37 7 51 305 21.7 6.4 32.6 -4.7 02/03/2006 21:10:00 6.7 0.5 8 5.3 6.6 0.5 7.6 5.3 33 4 24 305 24.3 7 33.6 1.5 02/03/2006 21:20:00 6.1 0.7 7.6 3.8 5.9 0.7 7.6 4.2 31 7 27 305 25.2 10.4 36.6 -3.6 02/03/2006 21:30:00 5.7 0.7 7.2 3.8 5.6 0.8 7.2 3.8 38 6 35 305 24.6 6.2 32.3 0.1 02/03/2006 21:40:00 6 0.6 7.6 4.6 5.8 0.6 7.2 4.2 44 8 41 305 23.1 7.3 31.4 2 02/03/2006 21:50:00 6.6 0.6 8 4.9 6.4 0.7 8.4 4.6 46 5 40 305 10.8 5 21.3 -15 02/03/2006 22:00:00 6.5 0.6 8 4.9 6.4 0.6 7.6 4.9 38 7 41 305 14 5.4 24 -12.9 02/03/2006 22:10:00 6.7 0.6 8 4.9 6.5 0.6 8 4.9 43 6 48 305 15.8 5.6 25.2 -1.8 02/03/2006 22:20:00 6.1 0.6 7.6 4.6 6 0.6 7.6 4.6 42 6 45 305 18.4 5.4 24.6 -14.6 02/03/2006 22:30:00 6 0.7 7.6 4.2 5.7 0.7 7.6 4.2 40 7 44 305 18.2 5 26.4 1.5 02/03/2006 22:40:00 6.4 0.7 8 4.6 6.2 0.7 7.6 4.6 41 7 55 305 15.2 5.6 25.8 3.7 02/03/2006 22:50:00 6.5 0.8 8.4 4.9 6.4 0.8 8 4.6 35 5 32 305 12.6 2.9 16.7 -7.9 02/03/2006 23:00:00 6.6 1.1 9.1 4.6 6.5 1.2 9.1 4.2 36 7 32 305 13.4 2.5 16.5 2.7 02/03/2006 23:10:00 7.5 0.8 8.8 5.3 7.4 0.9 9.1 5.3 38 7 40 305 11 2.6 15.6 3.2 02/03/2006 23:20:00 7.8 0.5 9.1 5.7 7.8 0.5 9.1 6.5 36 5 33 305 11.6 2.5 15.9 1.3 02/03/2006 23:30:00 7.5 0.8 9.1 5.3 7.5 1 9.5 4.9 40 5 38 305 12 2.5 16.2 3.2 02/03/2006 23:40:00 7.9 0.6 9.5 6.1 7.7 0.7 9.1 6.1 34 6 35 305 9.7 4.5 16.5 -15 02/03/2006 23:50:00 7.4 0.8 9.1 5.7 7.3 0.9 9.5 5.7 35 5 31 305 12.6 2.6 16.7 2.7 02/04/2006 00:00:00 7.2 0.6 8.8 5.7 7 0.7 8.8 5.3 39 8 48 305 11.5 3.7 17.3 -12.1 02/04/2006 00:10:00 7.3 0.8 9.5 4.9 7.2 0.9 9.5 4.9 39 5 36 305 11.1 4.5 16.5 -12.5 02/04/2006 00:20:00 7 0.6 8.8 5.7 6.8 0.6 8.8 4.9 40 6 30 305 12.3 2.8 16.5 -5.6 02/04/2006 00:30:00 7.7 0.8 9.9 5.7 7.6 0.9 9.5 5.7 46 6 37 305 12 2.5 16.2 4.2 02/04/2006 00:40:00 7.5 0.8 9.1 5.7 7.4 0.8 9.5 5.7 41 8 50 305 11.6 2.6 15.3 4.9 02/04/2006 00:50:00 7.9 0.7 9.5 5.7 8 0.8 9.9 5.7 30 5 27 305 11.3 2.7 15.9 2.2 02/04/2006 01:00:00 8.1 0.6 9.5 6.8 8 0.7 9.5 6.5 29 4 35 305 10.8 3.7 15.9 -11.5 02/04/2006 01:10:00 8.6 0.7 10.7 6.5 8.6 0.8 10.3 6.5 33 6 31 305 10.6 4 16.2 -13.5 02/04/2006 01:20:00 9.2 0.6 10.7 7.6 9.1 0.7 11.5 7.2 33 4 31 305 9.8 4.4 16.2 -13.7 02/04/2006 01:30:00 9 0.7 10.7 7.2 8.8 0.8 10.7 7.2 35 5 35 305 15.4 7.3 28.2 -14.6 02/04/2006 01:40:00 9.1 0.7 11.1 6.8 9 0.9 10.7 6.8 39 6 36 305 19.7 5.2 28.2 3.9 02/04/2006 01:50:00 8.6 0.6 10.3 6.8 8.5 0.8 10.3 6.8 34 5 36 305 18.6 6.4 28.8 2 02/04/2006 02:00:00 8.5 0.8 10.7 6.1 8.4 0.9 10.7 6.1 33 5 31 305 22 6.7 29.8 0.6 02/04/2006 02:10:00 7.8 1 11.1 5.3 7.7 1 10.7 5.3 34 7 46 305 17.2 6.2 27.3 2 02/04/2006 02:20:00 8.9 0.6 10.3 6.8 8.7 0.7 10.3 6.8 31 7 34 305 17.9 5.2 27 4.4 02/04/2006 02:30:00 9.3 0.8 10.7 6.8 9.2 0.9 11.1 6.5 32 4 34 305 15.8 3.7 23.7 3.2 02/04/2006 02:40:00 9.3 0.8 11.1 6.8 9.1 0.8 11.1 6.8 34 6 35 305 19.2 8.7 28.2 -16.4 02/04/2006 02:50:00 9.6 0.8 11.8 8 9.3 0.8 11.5 7.2 31 5 31 305 16.3 8.7 27.6 -13.9 02/04/2006 03:00:00 9.5 0.9 11.1 7.2 9.3 0.9 11.5 6.5 36 5 33 305 10.9 6.2 19.3 -15 02/04/2006 03:10:00 8.9 0.7 10.7 6.8 8.9 0.9 11.1 6.5 37 6 36 305 12.8 3.7 17.9 -8.8 02/04/2006 03:20:00 8.6 1 10.7 6.1 8.4 0.9 10.7 6.5 32 6 35 305 12 4.2 18.4 -13.7 02/04/2006 03:30:00 8.4 0.7 10.3 6.5 8.3 0.9 10.3 6.1 38 6 36 305 11 4.5 19.3 -13.1 02/04/2006 03:40:00 8.8 0.7 10.3 7.2 8.9 0.9 11.5 6.5 41 6 39 305 11.9 3.4 17.9 2.5 02/04/2006 03:50:00 8.9 1 11.8 6.1 8.7 1.1 11.5 6.1 38 6 28 305 11.6 3.7 17.6 -1.8 02/04/2006 04:00:00 9.8 0.8 11.8 6.8 9.7 0.9 12.2 6.5 38 5 30 305 9.7 3.5 15.6 -11.7 02/04/2006 04:10:00 9.9 0.8 12.2 7.6 9.9 1 12.2 7.6 37 5 36 305 9.3 3.7 15.3 -14.4 02/04/2006 04:20:00 9.8 0.8 11.8 7.6 9.4 0.8 11.8 7.6 38 5 35 305 8.9 5.6 17.6 -13.9 02/04/2006 04:30:00 9.9 0.8 12.2 8 9.6 0.8 12.2 6.8 36 5 36 305 12.4 3.7 17 -10 02/04/2006 04:40:00 10.2 0.8 12.6 8.4 9.9 0.9 11.8 7.6 38 6 44 305 8.6 4.5 17 -11.9 02/04/2006 04:50:00 9.5 1 12.2 6.8 9.3 1.2 12.6 6.1 35 6 38 305 11.4 3.7 17.3 -3.8 02/04/2006 05:00:00 9.8 0.8 11.8 7.6 9.5 0.8 11.1 7.6 31 5 23 305 10.9 3.5 17.3 -3.3 02/04/2006 05:10:00 9.6 1 12.2 7.2 9.4 1 11.8 6.8 25 6 15 305 10.4 3.5 17.6 4.7 02/04/2006 05:20:00 10 1.1 13.3 7.2 9.7 1.1 12.6 7.2 29 6 27 305 12.2 3.4 17.3 3.7 02/04/2006 05:30:00 10.7 0.9 13.3 8.8 10.4 1 13 8.4 32 6 37 305 10.6 3.2 16.2 4.4 02/04/2006 05:40:00 11 1.3 13.7 8 10.8 1.3 13.7 8 33 6 30 305 13.6 2.8 17 5.9 02/04/2006 05:50:00 10.6 0.9 12.6 8.4 10.6 1 12.6 8 34 5 35 305 12.5 2.8 16.5 4.7 02/04/2006 06:00:00 12.1 1.1 15.6 9.5 11.7 1.1 14.5 9.1 31 4 32 305 10 1.7 15.9 5.4 02/04/2006 06:10:00 13.3 1 16.1 9.9 13.2 1.2 16.1 9.5 34 5 36 305 11.5 3.5 16.7 -0.6 02/04/2006 06:20:00 12.5 1.1 14.9 9.5 11.8 1.1 14.1 8.8 31 5 35 305 10.7 3.2 15.6 0.6 02/04/2006 06:30:00 12 1 14.1 9.5 11.6 1 13.7 9.1 34 5 33 305 7.7 5 17.9 -14.6 02/04/2006 06:40:00 12.4 1.3 15.6 9.1 11.8 1.2 14.5 8.4 29 5 27 305 8.6 3.7 16.5 -6 02/04/2006 06:50:00 12.5 1.3 16.1 9.5 12.5 1.2 15.6 9.5 32 6 29 305 11 3.7 17.6 0.6 02/04/2006 07:00:00 12.1 1.2 14.9 9.5 11.4 1.1 14.9 8.8 31 5 29 305 14.9 6.4 27.3 0.3 02/04/2006 07:10:00 11 1.2 14.9 8 10.8 1.2 14.9 8 35 6 31 305 14.7 6.7 26.4 -1.1 02/04/2006 07:20:00 12.6 1.3 15.3 9.1 11.9 1.4 15.6 9.1 35 6 40 305 14.3 7.6 27.6 -7.7 02/04/2006 07:30:00 12.4 1.2 14.9 8.8 12.3 1.2 15.6 9.1 32 6 30 305 15 6.4 26.7 -7.7 02/04/2006 07:40:00 12.3 1.1 14.9 8.8 12.3 1.4 15.6 8.8 32 5 36 305 12.8 8.3 27.9 -7.3 02/04/2006 07:50:00 12.4 1.2 15.6 9.9 12 1.3 15.3 9.1 35 5 38 305 15.2 7 28.2 -13.7 02/04/2006 08:00:00 12.6 1.5 15.6 8.4 12.3 1.6 16.1 8 37 8 47 305 15.6 7 29.5 -0.8 02/04/2006 08:10:00 12.2 1.2 15.3 9.5 12.1 1.5 15.6 8.8 37 6 44 305 13.4 7.6 31.4 -8.8 02/04/2006 08:20:00 12.9 1.2 16.1 9.5 12.8 1.3 16.8 9.5 39 6 33 305 11 5.4 32 -5.8 02/04/2006 08:30:00 14.2 1.2 17.2 11.5 13.8 1.3 16.8 10.7 34 4 35 305 18.7 9.5 31.7 -14.4 02/04/2006 08:40:00 13.7 1.1 17.2 10.3 12.8 1.2 16.1 9.5 34 5 33 305 18 6.4 27.3 -4.5 02/04/2006 08:50:00 13.1 1.2 16.4 9.9 12.8 1.1 15.6 9.9 38 6 40 305 15.2 6.2 24.6 -16 02/04/2006 09:00:00 13.2 1.1 16.1 9.5 13.4 1.2 16.1 9.1 37 5 39 305 15.8 8 31.7 -13.3 02/04/2006 09:10:00 12.7 1.3 16.1 9.1 12.8 1.3 16.1 9.5 34 5 32 305 15.8 7.6 29.5 -10 02/04/2006 09:20:00 12.5 1.1 15.6 9.5 12.4 1.2 15.6 9.5 37 5 37 305 18.5 6.2 27.6 -0.4 02/04/2006 09:30:00 12.7 1.1 15.3 9.9 12.4 1.2 14.9 9.9 36 5 36 305 21.1 6.4 30.7 -10 02/04/2006 09:40:00 12 1.1 14.9 8.8 11.9 1.4 15.6 8.8 31 6 27 305 19.6 6.7 32 -9.8 02/04/2006 09:50:00 12.6 1.1 15.3 9.9 12.2 1.2 14.9 9.5 31 5 34 305 15.4 9.1 31 -13.7 02/04/2006 10:00:00 13.4 1.3 16.1 10.3 13.6 1.5 16.8 9.5 30 6 29 305 19.6 6.2 30.7 0.6 02/04/2006 10:10:00 13.1 1.3 16.8 10.3 13.6 1.5 16.4 9.9 30 5 29 305 16 7 31.4 -2.7 02/04/2006 10:20:00 13 1.7 17.2 9.1 12.5 1.7 16.8 8.8 29 5 31 305 16.5 6.7 28.2 -6 02/04/2006 10:30:00 14.7 1.3 17.9 11.1 14.5 1.5 18.3 10.3 29 5 27 305 19.1 6.7 28.2 -9 02/04/2006 10:40:00 15.3 1.2 17.9 11.8 14.5 1.2 17.6 11.1 28 5 27 305 18.3 6.4 28.5 -10 02/04/2006 10:50:00 14.4 1.3 17.9 11.5 13.5 1.4 17.2 10.3 28 7 29 305 9.9 3.5 15.1 -10.7 02/04/2006 11:00:00 13.1 1.5 17.2 9.9 12.7 1.7 17.6 9.1 29 6 28 305 16.6 5.9 24.9 -12.3 02/04/2006 11:10:00 14.9 1.4 17.9 11.5 14.6 1.5 17.9 11.1 27 5 29 305 19.2 3.5 25.8 4.2 02/04/2006 11:20:00 15.2 1.4 18.3 11.8 14.6 1.3 17.9 11.5 30 5 28 305 15.1 5.4 23.4 -14.4 02/04/2006 11:30:00 15.3 1.3 17.9 11.8 14.6 1.4 17.9 11.1 30 6 27 305 16.5 5.9 23.4 -13.3 02/04/2006 11:40:00 15.5 1.5 19.5 12.2 15.3 1.6 19.1 10.3 26 6 29 305 5.8 3.2 11.8 -16.4 02/04/2006 11:50:00 14.7 1.8 18.7 10.7 14.3 1.6 17.9 10.7 24 5 22 305 8.3 3.2 13.2 -1.3 02/04/2006 12:00:00 14.7 1.6 18.3 11.1 14.3 1.5 17.9 10.3 27 5 29 305 9.2 2.9 14 -6.2 02/04/2006 12:10:00 16.2 1.7 19.9 11.5 15.7 1.5 19.1 11.5 26 5 25 305 6.6 4.7 13.7 -15.8 02/04/2006 12:20:00 15.7 1.7 19.5 11.8 15.1 1.7 18.7 11.1 28 6 35 305 8.9 3.1 14.5 -7.7 02/04/2006 12:30:00 15.4 1.7 20.6 11.8 15.3 1.6 19.5 11.1 29 6 29 305 8.3 3.8 14 -11.9 02/04/2006 12:40:00 15.3 1.5 19.1 11.8 15 1.6 19.1 11.5 30 6 27 305 8.5 2.6 13.2 -2.7 02/04/2006 12:50:00 15.8 1.4 19.1 12.2 15.2 1.4 18.3 11.8 28 6 29 305 8.8 2.7 13.2 -2.7 02/04/2006 13:00:00 16 1.2 18.3 12.2 15.9 1.3 19.5 11.5 26 6 29 305 9.4 2.4 14.8 1 02/04/2006 13:10:00 15.3 1.7 19.9 11.1 15.1 1.7 20.2 11.5 30 6 28 305 6.9 5 14.8 -13.7 02/04/2006 13:20:00 16.9 1.6 19.9 12.6 16.6 1.6 20.6 12.2 31 5 28 305 7.1 4.4 14.3 -11.7 02/04/2006 13:30:00 16.4 1.6 19.9 11.5 16.1 1.7 20.2 11.8 29 6 26 305 11 6.4 24.9 -10.4 02/04/2006 13:40:00 15.3 1.5 19.1 11.8 14.9 1.5 19.1 11.8 28 5 30 305 13.4 7 27.3 -9.2 02/04/2006 13:50:00 15.7 1.7 19.5 11.8 15.6 1.7 19.5 11.8 29 5 27 305 10.3 6.2 26.4 -12.1 02/04/2006 14:00:00 15.6 1.5 19.1 11.8 15.5 1.7 19.5 11.1 28 6 27 305 8 4.2 14 -11.5 02/04/2006 14:10:00 16.5 1.5 20.6 12.6 16.2 1.7 19.9 11.8 32 5 35 305 6.8 3.5 12.4 -9.6 02/04/2006 14:20:00 15.9 1.6 19.5 11.1 15.6 1.7 19.9 11.5 29 6 25 305 5.8 4 12.4 -16.9 02/04/2006 14:30:00 16 1.7 20.2 11.8 15.8 1.8 20.2 11.5 28 6 25 305 5 4 10.2 -18.4 02/04/2006 14:40:00 16.5 1.8 21.4 11.8 16.4 1.7 19.9 11.8 31 6 32 305 4.2 3.2 10.2 -16.9 02/04/2006 14:50:00 15.8 2.1 20.2 11.5 15.6 1.9 20.2 11.5 29 6 28 305 4.9 2.9 10 -16.6 02/04/2006 15:00:00 17 1.7 21.4 12.2 16.7 1.7 21 11.8 30 6 27 305 5.2 2.4 9.5 -6 02/04/2006 15:10:00 16.3 1.4 19.9 12.2 16.1 1.6 20.6 12.2 26 5 23 305 5.6 2.6 10.5 -1.5 02/04/2006 15:20:00 16.1 1.9 20.6 11.8 15.9 1.8 21.4 11.8 29 6 33 305 4.7 2.5 10 -1.1 02/04/2006 15:30:00 16.4 1.7 20.6 12.6 16.1 1.8 21.8 11.8 28 5 29 305 9.7 7.6 23.4 -15.8 02/04/2006 15:40:00 16.2 1.6 20.2 12.2 15.9 1.7 20.2 11.5 29 6 33 305 16.5 4.5 21.9 -3.8 02/04/2006 15:50:00 17.1 1.8 21.4 12.6 16.8 1.7 20.6 12.6 27 6 27 305 15.8 4.5 22.8 -10.9 02/04/2006 16:00:00 17.7 1.7 22.1 13.3 17.4 1.6 21.4 13 27 5 31 305 16.3 5.4 22.5 -2.7 02/04/2006 16:10:00 18.2 1.5 22.1 14.5 18.3 1.6 21.8 13.7 29 6 19 305 14.5 5.2 20.7 -15 02/04/2006 16:20:00 16.9 1.7 21.4 13.3 16.9 1.7 21.8 13 30 6 39 305 16.9 3.7 21.9 -0.6 02/04/2006 16:30:00 16.7 1.9 21 12.6 16.7 1.9 21.4 13 29 6 28 305 17.4 2.6 21.6 2.5 02/04/2006 16:40:00 17.5 1.7 21.8 13.3 17.3 1.7 21 12.6 28 6 27 305 14.8 5.6 23.1 -14.3 02/04/2006 16:50:00 18.4 1.8 22.9 13.7 18.5 1.8 22.9 13 32 6 26 305 18.4 4.4 24.3 1.3 02/04/2006 17:00:00 18 1.7 22.6 12.6 17.8 1.8 22.6 12.2 27 6 38 305 21.7 3.2 25.2 -1.8 02/04/2006 17:10:00 18.2 1.8 22.1 13.7 17.9 1.7 22.1 13 28 6 24 305 21.2 2.1 24.9 8.9 02/04/2006 17:20:00 17.6 2.2 23.3 12.2 17.3 2.1 22.6 12.2 29 6 27 305 20.9 2.2 24.9 5.6 02/04/2006 17:30:00 17.9 2.1 22.9 12.6 17.7 2.1 22.9 12.2 30 6 28 305 20.4 1.9 24 8.7 02/04/2006 17:40:00 20.2 2 24.4 15.3 20 2 24.4 14.5 30 5 31 305 18.5 3.7 24.3 -4.9 02/04/2006 17:50:00 19.5 2.1 24.4 14.5 19.4 2.2 24.8 15.3 31 6 33 305 17 3.1 21.3 -1.1 02/04/2006 18:00:00 18.6 2.3 24 13.7 18.6 2.2 24 13.7 33 7 40 305 19 4.5 24.3 -6.7 02/04/2006 18:10:00 18.2 1.7 22.9 13.7 18.1 1.7 22.9 13.7 32 6 31 305 4.4 4 10.8 -15.8 02/04/2006 18:20:00 19.3 2 23.7 14.9 19 2.1 23.7 14.9 32 6 23 305 5.6 2.8 10.2 -5.8 02/04/2006 18:30:00 19 2.2 23.3 13.7 18.7 2.3 23.3 13.7 29 6 27 305 5.5 2.7 10.2 -1.3 02/04/2006 18:40:00 17.5 1.7 22.6 13.3 17.3 1.7 22.6 13 30 6 23 305 4.8 3.8 9.2 -15 02/04/2006 18:50:00 18.3 2 22.9 13.7 18.3 1.8 23.7 13.7 29 7 23 305 5.1 2.9 10.2 -2 02/04/2006 19:00:00 19.7 1.9 24 14.5 19.6 2 24.8 14.5 28 6 27 305 5 3.4 10.2 -4.7 02/04/2006 19:10:00 18.4 2.3 23.3 12.6 18.3 2.3 23.7 13 29 6 33 305 7.7 3.4 12.9 -23.7 02/04/2006 19:20:00 18.9 1.8 23.3 14.1 18.7 1.7 23.7 14.5 31 6 27 305 6 3.2 11.8 -12.7 02/04/2006 19:30:00 19.7 2.3 25.2 14.1 19.6 2.3 24.8 14.9 28 6 34 305 5.8 2.7 11.3 -12.1 02/04/2006 19:40:00 19.9 1.7 24.4 15.3 19.7 1.8 24.8 15.3 30 6 31 305 5.8 2.8 10.8 -11.9 02/04/2006 19:50:00 19 2.3 23.7 14.1 18.9 2.3 23.7 14.1 32 5 35 305 3.2 3.7 9.7 -13.7 02/04/2006 20:00:00 19.7 2.1 23.7 13.7 19.5 1.9 23.7 14.1 28 5 28 305 5 2.8 10 -9 02/04/2006 20:10:00 19.2 1.7 23.3 14.5 19.2 1.8 23.3 14.9 25 5 23 305 2.5 3.4 8.2 -9.2 02/04/2006 20:20:00 19.2 1.7 23.3 14.9 19.1 1.7 23.3 14.1 27 5 20 305 4.8 2.7 9.5 -4.7 02/04/2006 20:30:00 18.9 1.7 23.7 14.5 18.6 1.8 23.3 13.7 27 6 27 305 3.9 4.2 9.7 -13.3 02/04/2006 20:40:00 18.5 2.1 24.4 13.7 18.3 2.2 25.2 14.1 29 6 39 305 4.7 4.2 10.2 -13.7 02/04/2006 20:50:00 18.5 1.9 23.3 14.1 18.3 2 23.7 13 31 6 30 305 6.2 2.7 11.3 -0.6 02/04/2006 21:00:00 19.8 2 24 13.3 19.5 1.9 24.4 14.1 29 6 29 305 6.5 3.1 13.4 -4.7 02/04/2006 21:10:00 19 1.9 23.7 14.5 18.9 1.8 23.3 14.1 31 6 37 305 5.8 4.7 13.2 -23.2 02/04/2006 21:20:00 19 2.4 25.2 14.5 18.8 2.3 25.2 14.5 28 6 29 305 5.7 3.2 12.4 -10.9 02/04/2006 21:30:00 19.2 1.9 23.3 14.5 18.8 2.1 23.7 14.5 29 6 28 305 5.7 3.8 12.6 -11.3 02/04/2006 21:40:00 18.9 2.1 24.4 13.7 18.7 2.1 25.2 14.5 29 6 30 305 6 3.7 12.9 -10.4 02/04/2006 21:50:00 19.9 2 24 14.9 19.8 1.9 25.2 14.9 31 6 33 305 7.5 3.8 13.2 -10.4 02/04/2006 22:00:00 19.9 2.2 24.4 15.3 19.8 2.2 26 14.5 31 6 24 305 18.8 7 28.2 -0.4 02/04/2006 22:10:00 20.9 2.3 26 14.9 20.5 2.4 25.6 12.2 31 6 23 305 14.9 7 24 -12.7 02/04/2006 22:20:00 21.5 1.8 24.8 16.8 21.2 1.8 24.8 16.4 33 6 37 305 7.5 5.2 15.3 -12.1 02/04/2006 22:30:00 20.5 2.3 24.8 14.1 20.3 2.3 25.6 14.5 32 6 30 305 9.9 2.8 15.1 -11.9 02/04/2006 22:40:00 19.7 2.3 24 14.1 19.5 2.3 24 14.1 31 6 31 305 7.7 1.6 11.6 2.7 02/04/2006 22:50:00 19.3 1.9 24.4 15.3 19.3 1.9 23.7 14.9 31 6 32 305 9.6 6.7 27.6 -0.1 02/04/2006 23:00:00 20.2 2.1 24.4 15.3 19.9 2 24 15.3 30 6 32 305 21.3 3.4 27.3 0.1 02/04/2006 23:10:00 19.1 2.1 23.3 13.3 18.9 2.1 22.9 13.7 28 6 27 305 20.1 3.5 25.2 2.9 02/04/2006 23:20:00 20.1 2.4 24.4 13.7 19.9 2.4 24.8 14.1 29 6 33 305 18.1 6.2 24.9 -7.9 02/04/2006 23:30:00 19.5 2.4 24.8 13.3 19.1 2.4 24.8 13 29 6 23 305 20.9 1.8 24.9 16.2 02/04/2006 23:40:00 19.9 1.9 24 15.3 19.7 2 24.4 14.5 30 6 32 305 19.1 5 24.9 -8.6 02/04/2006 23:50:00 20.2 2.3 24.8 14.5 19.9 2.4 24.4 13.7 27 6 24 305 9.9 6.4 22.8 -10.9 02/05/2006 00:00:00 19.2 2.2 24 13.7 18.8 2.3 24.4 13 28 6 24 305 13.2 9.9 29.2 -9.2 02/05/2006 00:10:00 19.5 2.8 25.6 13.3 19.4 2.8 26 12.6 31 7 22 305 22.7 2.5 27.6 17.3 02/05/2006 00:20:00 20.3 2.4 25.2 15.3 20 2.4 24.8 14.1 30 6 19 305 12.3 6.7 27.6 -9.6 02/05/2006 00:30:00 19.4 2.4 25.2 14.1 19 2.4 25.2 13.3 30 6 27 305 6.7 5.6 14.8 -9 02/05/2006 00:40:00 18.4 2.1 23.7 13.3 18.1 2.1 24 13.3 27 7 25 305 7 5.6 15.3 -8.8 02/05/2006 00:50:00 19.7 2.4 25.6 14.9 19.2 2.4 25.2 13.3 31 6 21 305 9.2 3.7 15.1 -8.2 02/05/2006 01:00:00 18.7 2.1 24 13.3 18.2 2.2 23.3 13 29 7 27 305 9.3 4 15.3 -9 02/05/2006 01:10:00 18.5 2 23.7 13.3 18.2 2 23.3 13.3 31 7 30 305 11.4 3.7 17.3 -9 02/05/2006 01:20:00 19.3 1.8 24 14.1 19 1.9 23.7 14.5 31 6 33 305 8.2 5.6 15.3 -10.7 02/05/2006 01:30:00 19.8 1.9 25.2 15.3 19.5 2 25.2 14.9 31 7 27 305 9.7 4.4 16.7 -10 02/05/2006 01:40:00 19.5 2.3 24.8 13.3 19.2 2.4 26 14.1 31 7 26 305 19 3.2 25.5 4.7 02/05/2006 01:50:00 19.6 2.5 24.8 13.3 19.2 2.6 25.6 13.7 30 7 32 305 18.7 2.4 23.7 10.5 02/05/2006 02:00:00 18.5 2.2 24.4 13.7 18.1 2.2 24.4 13.3 31 6 17 305 18.4 3.8 25.2 -2.7 02/05/2006 02:10:00 18.4 2.7 24.4 11.8 18.2 2.8 25.2 12.2 31 7 35 305 20.1 4.2 27.9 6.1 02/05/2006 02:20:00 19.1 2.2 24.4 14.1 18.8 2.2 24.4 14.1 33 7 26 305 18.7 6.4 27.6 -5.8 02/05/2006 02:30:00 18 2.1 23.3 12.2 17.8 2.2 23.7 12.2 35 7 37 305 10.3 6.7 26.4 -7.3 02/05/2006 02:40:00 18.5 1.9 22.9 13.7 18.4 2 22.9 14.1 37 7 39 305 18.6 7 28.8 -7.1 02/05/2006 02:50:00 19 2.5 25.2 14.5 18.8 2.5 24.8 14.1 37 7 36 305 10.4 5 25.8 -17.1 02/05/2006 03:00:00 19.7 2.5 25.6 13.7 19.5 2.5 25.6 14.5 38 7 39 305 10.6 4.4 16.5 -8.4 02/05/2006 03:10:00 19.4 2.4 25.2 14.1 19.2 2.5 26 13.7 39 6 36 305 10.8 3.4 17.6 2.2 02/05/2006 03:20:00 20.2 1.9 24.8 14.9 20 2 24.8 14.9 37 7 40 305 11.5 3.7 17 -4.9 02/05/2006 03:30:00 20 2.1 23.7 14.5 19.8 2 24 14.5 36 6 42 305 11.2 4.5 17.6 -5.1 02/05/2006 03:40:00 19.3 1.9 23.3 13.7 18.9 2.1 24 14.1 34 6 35 305 22 3.2 27.3 7.2 02/05/2006 03:50:00 18.7 2.3 23.7 14.1 18.5 2.3 24 13.7 35 6 41 305 21.2 4.5 29.5 6.4 02/05/2006 04:00:00 17.6 1.9 21.8 12.2 17.2 2 21.4 12.6 33 7 18 305 19.9 8 28.5 -7.1 02/05/2006 04:10:00 17.4 2 22.9 13 17.1 2 23.3 13.3 34 7 33 305 21.3 3.7 28.5 10.2 02/05/2006 04:20:00 18.4 2.2 23.7 11.8 18.4 2.2 23.7 13 38 7 29 305 14.9 8 30.1 -7.7 02/05/2006 04:30:00 18 2.1 23.3 13.3 17.8 2.1 24 13.3 38 7 35 305 24.1 3.1 30.4 15.6 02/05/2006 04:40:00 19.2 2.6 24.4 12.2 19 2.6 24.4 12.6 36 6 32 305 20.5 4.4 29.8 0.3 02/05/2006 04:50:00 18.6 2.2 23.7 12.6 18.5 2.2 22.9 12.2 36 6 33 305 21.8 3.4 28.8 5.9 02/05/2006 05:00:00 19 1.8 23.3 14.1 18.6 1.9 23.3 13 32 6 32 305 13.3 4.2 26.4 -0.1 02/05/2006 05:10:00 18 1.6 21.8 14.5 17.8 1.6 21.8 14.1 33 6 30 305 12 3.4 17.6 -12.7 02/05/2006 05:20:00 17.5 1.6 22.6 13 17.2 1.5 23.3 13.7 33 6 35 305 12.2 3.8 18.7 -14.3 02/05/2006 05:30:00 17.8 1.8 22.1 13.3 17.7 1.7 22.1 13 32 6 25 305 10.6 5 18.7 -6 02/05/2006 05:40:00 16.7 2.3 21.8 11.5 16.5 2.4 21.8 11.5 38 8 39 305 12.6 4 20.4 -4 02/05/2006 05:50:00 17 2.7 24 11.8 16.9 2.8 24.8 11.5 42 8 39 305 12.5 3.5 20.1 -3.8 02/05/2006 06:00:00 18.1 2.5 24 11.8 18 2.6 24 11.8 41 8 44 305 11.9 3.8 20.4 -4 02/05/2006 06:10:00 16.2 1.7 20.6 12.2 16.1 1.9 20.6 12.2 41 7 49 305 12.3 4.5 19.9 -3.3 02/05/2006 06:20:00 18.4 2.5 23.7 12.6 18.3 2.5 24 12.2 43 6 47 305 16.6 3.7 21.3 -3.1 02/05/2006 06:30:00 19.2 2.6 25.6 13 18.9 2.6 26 13 44 8 48 305 15.7 3.2 20.7 -2.9 02/05/2006 06:40:00 18.9 2.2 24.8 13.7 18.8 2.2 25.6 14.1 45 6 41 305 16.9 2.2 20.4 3.7 02/05/2006 06:50:00 18.5 2.1 24 13.7 18.2 2.1 24 13.3 44 8 43 305 16.7 2.9 21.3 -2.4 02/05/2006 07:00:00 18.9 2.1 24.8 14.1 18.7 2.1 24 14.1 42 7 33 305 15.2 4.5 21 -2.7 02/05/2006 07:10:00 20.4 2.3 26 14.9 20.2 2.3 26 14.5 42 6 51 305 16.8 3.8 21.9 -2.7 02/05/2006 07:20:00 19.3 2.4 25.2 13.3 19.2 2.5 26 13.7 42 7 39 305 10.4 4.5 15.9 -2.7 02/05/2006 07:30:00 20.8 2.2 25.6 15.3 20.7 2.2 26.3 15.3 40 6 41 305 12.3 5 20.4 -2.2 02/05/2006 07:40:00 19.5 2.6 25.6 12.6 19.4 2.6 26 13.3 42 6 31 305 13.8 5.2 21.9 -2 02/05/2006 07:50:00 17.7 2.2 24.8 13.3 17.6 2.2 23.3 12.6 40 7 51 305 18.7 2.8 22.5 2 02/05/2006 08:00:00 17.6 2.2 23.7 13 17.4 2.2 23.3 13 41 7 42 305 16.6 3.7 21.9 -2 02/05/2006 08:10:00 19.5 2.2 26 14.5 19.4 2.2 24.8 13.3 40 8 35 305 11.2 4 15.6 -2 02/05/2006 08:20:00 19.7 1.8 23.7 15.3 19.7 1.9 24 14.5 44 6 41 305 8 6.2 19.6 -2 02/05/2006 08:30:00 19.8 1.8 24 15.3 19.6 1.9 24.4 15.3 43 6 41 305 13.1 5.2 21.6 -1.5 02/05/2006 08:40:00 18.5 1.7 22.9 14.1 18.5 1.8 23.7 14.1 42 6 46 305 13.5 3.8 20.4 -1.3 02/05/2006 08:50:00 20 2.4 24.8 13.3 19.7 2.5 25.6 12.6 37 6 48 305 12.8 3.8 20.1 -1.3 02/05/2006 09:00:00 19.7 2.1 25.2 14.1 19.3 2.1 24.8 14.5 40 7 27 305 12.6 4.2 19.6 -1.1 02/05/2006 09:10:00 18.2 1.9 22.1 13.3 18 1.9 22.6 13 39 8 33 305 14.9 3.7 21 -1.1 02/05/2006 09:20:00 18.9 1.9 22.9 13.7 18.7 1.9 23.7 14.5 39 6 35 305 13.1 4.5 20.7 -1.1 02/05/2006 09:30:00 18.2 2.1 22.9 12.6 17.9 2.1 23.3 12.6 38 6 45 305 14.1 3.1 19.6 -0.8 02/05/2006 09:40:00 19 1.8 23.3 14.1 18.8 1.9 23.7 14.5 41 6 37 305 15.2 5.2 23.7 -0.6 02/05/2006 09:50:00 18.3 2.2 23.3 13 18 2.3 23.3 13 40 7 44 305 15.4 3.7 21.9 0.6 02/05/2006 10:00:00 18.1 2 23.3 14.1 18 2.1 24 13.3 41 6 40 305 15.9 4.5 22.5 0.6 02/05/2006 10:10:00 19.2 2.2 24.4 13 19.1 2.1 23.7 12.6 39 6 39 305 17.6 4.2 23.7 0.6 02/05/2006 10:20:00 17.5 2.2 21.8 12.6 17.4 2.2 22.1 11.5 39 7 40 305 19.7 2.4 24.3 4.7 02/05/2006 10:30:00 18.2 1.7 22.6 13.7 18.1 1.7 21.8 13.3 37 7 35 305 18.2 2.9 23.4 6.1 02/05/2006 10:40:00 17.3 1.8 22.1 13 17.1 1.7 21 13 37 6 36 305 16.3 3.1 22.2 1 02/05/2006 10:50:00 18.5 2.2 22.6 12.6 18.4 2.3 22.9 13 38 6 37 305 16.1 5 23.7 1 02/05/2006 11:00:00 18.1 2 22.6 13.3 18 1.9 23.3 13.3 38 6 44 305 19.4 2.8 23.4 4.7 02/05/2006 11:10:00 17.1 1.7 21.8 12.6 17 1.7 21.4 11.8 37 6 30 305 20.4 1.6 24 15.1 02/05/2006 11:20:00 17.5 2.2 22.6 13 17.5 2.1 22.1 13 39 7 29 305 18.1 3.5 23.7 2.2 02/05/2006 11:30:00 18.1 1.9 22.1 12.2 17.8 1.9 22.1 11.8 39 7 37 305 20 2.5 24.3 7.9 02/05/2006 11:40:00 18.4 2.1 24.4 13.3 18.2 2.2 25.2 12.6 42 6 43 305 19.3 2.8 24 4.4 02/05/2006 11:50:00 17.5 1.8 22.1 13 17.7 1.8 22.6 12.6 42 6 44 305 20.3 2.4 24.3 14.8 02/05/2006 12:00:00 18.8 1.9 23.3 13.3 18.7 2 23.3 13.3 42 7 32 305 16.5 5.2 23.7 3.9 02/05/2006 12:10:00 16.1 2.2 21 11.8 16 2.1 21 9.9 39 7 34 305 15.6 4.4 20.4 4.4 02/05/2006 12:20:00 18.7 2.6 23.3 12.6 18.6 2.5 24.4 13.3 39 7 42 305 16.4 4.4 27.3 5.2 02/05/2006 12:30:00 18.4 1.8 22.9 13 18.2 1.9 23.7 12.6 41 6 38 305 20.4 8 28.2 5.4 02/05/2006 12:40:00 17.9 2.2 22.9 11.8 17.8 2.3 22.9 12.2 37 8 39 305 22 7.3 27.9 5.9 02/05/2006 12:50:00 18.1 1.8 22.6 13.3 17.8 1.8 22.6 12.6 35 6 30 305 19.9 6.7 27.6 5.9 02/05/2006 13:00:00 18.3 2.6 22.9 12.6 18.3 2.6 24 11.8 36 7 44 305 21.3 5.9 27.9 6.1 02/05/2006 13:10:00 16.3 2 21.8 11.5 16 2 21.4 10.7 37 8 34 305 19.3 5.6 28.5 6.7 02/05/2006 13:20:00 16.1 1.8 20.6 11.8 16 1.8 20.6 11.1 38 6 48 305 20.8 4.5 28.5 4.7 02/05/2006 13:30:00 16.1 1.7 21 11.5 15.8 1.7 20.6 11.8 37 7 45 305 17.8 5.6 28.2 5.9 02/05/2006 13:40:00 16.4 1.8 20.6 11.1 16.2 1.8 19.9 11.5 35 6 28 305 19.3 4.2 27.3 7.2 02/05/2006 13:50:00 18.4 2.3 23.3 10.3 18.1 2.4 23.7 10.7 34 6 32 305 21.4 5.2 28.2 6.7 02/05/2006 14:00:00 17.5 1.8 21.4 12.6 17.2 1.7 21.8 12.6 36 6 35 305 21.6 4.5 28.8 6.4 02/05/2006 14:10:00 16.1 2 20.6 11.8 16 2.1 20.6 11.8 37 6 38 305 24.9 4 29.5 7.2 02/05/2006 14:20:00 16.8 1.9 21.4 12.6 16.8 1.8 21.8 11.8 38 6 39 305 22.9 3.8 28.5 6.4 02/05/2006 14:30:00 16.4 1.9 21.4 11.8 16.2 1.9 21 11.5 38 6 44 305 22.7 2 25.8 6.1 02/05/2006 14:40:00 15.3 1.5 18.7 11.8 15 1.5 18.3 10.3 34 7 28 305 20.8 2.9 24.9 4.2 02/05/2006 14:50:00 15.5 1.8 20.2 11.8 15.2 1.7 20.6 10.7 34 7 31 305 19.3 1.2 21.3 10 02/05/2006 15:00:00 15.6 1.9 21.4 11.5 15.4 1.8 21.8 11.8 32 6 34 305 19.7 2.9 24.9 6.4 02/05/2006 15:10:00 16.1 1.6 20.6 12.2 15.9 1.5 19.5 11.8 35 6 34 305 12.8 6.7 24.9 6.1 02/05/2006 15:20:00 17.1 1.9 21 12.6 16.9 1.9 21 12.2 33 5 23 305 18.8 2.3 23.7 7.2 02/05/2006 15:30:00 16.3 2.2 22.6 11.5 16.1 2.1 22.1 11.5 38 9 40 305 17.8 3.4 21.3 6.9 02/05/2006 15:40:00 16 1.7 20.2 11.5 15.8 1.8 20.2 11.5 37 7 48 305 17.5 3.7 22.5 7.2 02/05/2006 15:50:00 17.9 2.1 22.9 12.2 17.5 2.2 22.6 12.2 38 6 47 305 18.4 3.5 24 7.7 02/05/2006 16:00:00 16.7 1.8 21.4 11.1 16.4 2 22.1 11.5 39 7 50 305 18.3 2.6 23.4 7.9 02/05/2006 16:10:00 17.4 2.3 22.1 11.5 17.1 2.2 22.1 12.2 37 6 37 305 18.1 3.4 22.5 7.7 02/05/2006 16:20:00 16.6 2.2 22.1 10.3 16.4 2.3 22.1 11.1 39 6 43 305 19.8 3.7 25.2 7.9 02/05/2006 16:30:00 15.5 2.1 21 10.3 15.4 2.1 20.6 10.7 43 7 39 305 18.1 6.7 27.3 6.4 02/05/2006 16:40:00 15.7 2 21.8 12.2 15.6 2 22.1 11.5 41 7 42 305 25.9 3.8 28.5 9.2 02/05/2006 16:50:00 14.9 2 19.9 10.3 14.8 2.1 20.6 10.3 44 7 52 305 26.2 3.7 29.8 9.2 02/05/2006 17:00:00 16.9 1.7 21.8 12.6 16.7 1.9 22.1 11.8 43 7 49 305 25.3 2.8 27.6 9.2 02/05/2006 17:10:00 15.7 1.9 20.2 10.7 15.7 1.9 20.6 10.3 43 6 45 305 25.8 2 28.5 10.2 02/05/2006 17:20:00 16 1.5 19.9 12.6 15.9 1.5 19.9 11.8 42 7 43 305 30 3.1 33.3 13.2 02/05/2006 17:30:00 16 1.6 19.9 12.2 15.9 1.6 19.9 11.1 40 9 45 305 26.4 2.7 28.8 11.8 02/05/2006 17:40:00 15.2 1.6 19.1 11.5 15.1 1.7 19.1 10.7 41 7 45 305 26.8 3.2 29.8 11.3 02/05/2006 17:50:00 15.6 1.7 19.5 12.2 15.4 1.7 19.5 11.1 39 5 37 305 26.4 3.7 29.5 10.8 02/05/2006 18:00:00 16.5 2.2 21.8 12.2 16.2 2.1 21.8 11.1 41 6 36 305 25.8 3.1 28.5 11.6 02/05/2006 18:10:00 16.8 2.2 22.1 12.2 16.8 2.4 21.8 11.8 43 7 35 305 27.1 2.8 29.8 12.4 02/05/2006 18:20:00 15.9 2 20.6 10.7 15.9 2.1 21.8 11.1 44 7 57 305 27.4 3.7 29.8 13.4 02/05/2006 18:30:00 16.4 1.7 21.8 12.2 16.3 1.8 21 12.2 43 8 41 305 27.2 2.9 29.5 12.9 02/05/2006 18:40:00 16.1 2.2 21.8 11.5 15.9 2 21 11.5 43 8 35 305 27.5 1.9 29.5 14 02/05/2006 18:50:00 17 1.6 20.6 11.1 17 1.7 21 12.2 43 7 46 305 26.9 3.8 30.1 12.9 02/05/2006 19:00:00 16.8 2.3 21.4 11.1 16.6 2.2 20.6 11.1 41 7 35 305 27.4 1.8 29.2 12.9 02/05/2006 19:10:00 16.4 2 20.2 10.7 16.4 2 19.9 9.9 45 7 48 305 26.4 2.6 29.2 12.4 02/05/2006 19:20:00 15.4 2.3 20.6 9.9 15.3 2.3 19.9 9.5 42 6 38 305 26.3 3.5 29.5 13.2 02/05/2006 19:30:00 16.5 1.7 21.4 12.2 16.4 1.9 21.4 11.8 46 6 43 305 26.1 3.8 28.5 13.4 02/05/2006 19:40:00 15.6 1.7 19.9 11.8 15.6 1.6 19.9 11.5 43 7 33 305 24.4 5.4 29.8 14.8 02/05/2006 19:50:00 15.5 1.3 18.3 11.5 15.5 1.5 19.1 11.1 43 6 49 305 20.9 5.6 28.8 15.1 02/05/2006 20:00:00 14.3 1.5 17.9 10.3 14.3 1.6 18.3 10.3 41 6 39 305 26.6 5.9 31.7 15.6 02/05/2006 20:10:00 15 1.5 18.7 11.1 15.1 1.7 19.1 10.3 44 6 48 305 24.3 6.4 31.4 15.3 02/05/2006 20:20:00 16.7 1.6 21 12.2 16.7 1.7 21 12.2 47 6 45 305 19.4 6.7 35.3 15.9 02/05/2006 20:30:00 14.6 1.7 19.9 10.7 14.6 1.7 19.9 9.9 43 6 43 305 25.6 7.6 33.6 16.2 02/05/2006 20:40:00 16.9 2.1 21.4 11.1 16.8 2.3 21.8 11.5 42 6 42 305 26.1 9.1 36.2 15.9 02/05/2006 20:50:00 17.4 1.7 21 13 17.4 1.7 21.4 13 41 6 39 305 25.1 8 35.3 17.3 02/05/2006 21:00:00 17.3 1.7 21.4 12.6 17.3 1.7 21.4 12.6 42 6 48 305 27.7 9.9 41.3 17.9 02/05/2006 21:10:00 16.7 1.8 21 12.6 16.5 1.9 22.1 12.6 40 6 41 305 31 6.7 40.6 21.9 02/05/2006 21:20:00 16.2 1.8 20.6 11.8 16.3 1.7 20.6 11.1 41 8 35 305 27.3 7 40.6 21.9 02/05/2006 21:30:00 15.9 2.2 21.8 11.1 15.8 2.3 21.8 11.5 42 6 44 305 33 6.7 40 17.6 02/05/2006 21:40:00 15.8 2.1 21.4 11.1 15.6 2.2 21.4 11.1 40 6 36 305 23.2 1.9 25.2 18.7 02/05/2006 21:50:00 13.9 1.5 18.7 10.3 13.7 1.5 17.9 9.5 36 7 25 305 32.1 8 39.6 19.6 02/05/2006 22:00:00 13 1.7 17.9 9.5 13 1.6 17.6 9.5 39 8 21 305 25.5 7.3 38.3 17.9 02/05/2006 22:10:00 13.6 1.5 17.2 9.5 13.5 1.5 17.2 9.9 39 7 44 305 25.8 7.6 40 19 02/05/2006 22:20:00 13.8 1.7 17.6 9.1 13.7 1.7 17.9 8.4 37 7 35 305 23.7 5.4 37.6 19.6 02/05/2006 22:30:00 15.4 1.7 21 11.1 15.4 1.7 21 11.1 39 7 26 305 20.9 1 21.9 16.5 02/05/2006 22:40:00 15.6 1.9 20.2 11.1 15.4 1.9 19.9 11.1 38 6 40 305 25.7 6.2 36.9 20.4 02/05/2006 22:50:00 16.1 2.1 21 11.5 15.8 2 21 11.5 39 6 29 305 28.9 6.2 36.6 20.4 02/05/2006 23:00:00 16 2 21.4 11.5 15.7 1.9 21 10.7 38 6 35 305 32.3 4 36.9 21.9 02/05/2006 23:10:00 15.5 1.9 20.2 10.7 15.2 1.8 19.5 10.7 37 7 43 305 31.8 5 36.2 21 02/05/2006 23:20:00 17.2 2.1 21 11.1 17 2.1 21 10.7 38 6 36 305 32.2 4.2 35.9 21 02/05/2006 23:30:00 15.2 1.9 20.6 10.3 15 1.8 20.2 11.1 39 7 41 305 27.8 5.4 34.3 19.9 02/05/2006 23:40:00 16.5 2.1 21.4 9.9 16.2 2.1 21.4 9.1 36 6 40 305 28.5 4.7 33.3 7.4 02/05/2006 23:50:00 15.3 2.1 21.4 10.3 15.1 2.1 21 10.7 38 7 39 305 28.4 4.4 32.6 17.9 02/06/2006 00:00:00 15.1 1.8 21 10.7 14.9 1.9 21.8 10.3 38 7 37 305 25.6 5.6 33.9 19.6 02/06/2006 00:10:00 15.9 2.3 21.4 11.5 15.7 2.2 22.1 11.8 40 7 40 305 29.1 7.3 33.9 -17.7 02/06/2006 00:20:00 17 1.8 20.6 11.8 17 1.9 21.4 12.2 42 6 36 305 29.9 2.7 33.3 20.4 02/06/2006 00:30:00 15.7 2 21 11.5 15.7 2 20.6 11.1 39 7 46 305 28.8 2.2 31 20.4 02/06/2006 00:40:00 16.8 2.4 21.8 9.5 16.5 2.5 21.4 9.9 36 7 30 305 34.9 5 38.6 8.9 02/06/2006 00:50:00 16.2 1.7 19.9 11.8 15.9 1.7 20.2 11.5 31 6 32 305 22.8 3.2 27.6 15.9 02/06/2006 01:00:00 14.2 1.8 19.1 10.3 14 1.8 18.7 9.9 31 7 22 305 22.2 6.2 34.6 7.7 02/06/2006 01:10:00 14.5 1.7 19.5 10.3 14.4 1.7 19.9 9.9 30 6 27 305 37.4 2.3 42.7 27.3 02/06/2006 01:20:00 14.2 2.1 20.2 10.3 13.9 2.1 19.9 10.3 33 7 34 305 36.4 2.2 40.6 26.7 02/06/2006 01:30:00 15.5 1.7 19.9 11.8 15.2 1.7 19.9 11.1 33 6 35 305 35.3 2.6 38.6 24.9 02/06/2006 01:40:00 15.8 2 20.6 11.1 15.4 2 20.2 11.5 33 7 35 305 33.1 2.6 37.9 20.4 02/06/2006 01:50:00 14.7 1.5 18.3 11.5 14.6 1.3 17.9 11.1 37 6 33 305 33 1.4 36.6 23.1 02/06/2006 02:00:00 15.2 1.8 21 10.7 14.9 1.8 19.9 10.3 37 8 40 305 32.6 2 35.3 21 02/06/2006 02:10:00 15.7 1.7 19.5 11.1 15.3 1.7 19.9 10.7 39 6 37 305 32.5 2.7 37.6 21.9 02/06/2006 02:20:00 14.5 1.5 17.9 9.9 14.5 1.5 17.9 11.1 40 7 36 305 34.8 1.7 37.9 22.2 02/06/2006 02:30:00 17.1 1.6 21 12.2 16.8 1.5 21.4 12.6 37 7 41 305 34.7 2 38.6 21 02/06/2006 02:40:00 14.6 1.5 17.9 11.1 14.4 1.5 18.3 11.1 40 7 49 305 33.5 1.5 36.6 21 02/06/2006 02:50:00 15.1 1.7 19.5 11.1 14.9 1.7 19.1 10.3 38 7 23 305 33 1.6 36.6 20.4 02/06/2006 03:00:00 16.1 2.2 21 10.7 15.8 2.2 20.6 10.3 42 6 35 305 32.6 2.2 35.9 20.1 02/06/2006 03:10:00 14.8 1.7 19.5 10.3 14.7 1.8 19.1 10.7 39 6 44 305 31.8 3.2 35.9 10.8 02/06/2006 03:20:00 15 1.5 19.5 11.1 14.9 1.5 18.7 11.1 39 7 37 305 31.9 1.8 35.9 24.6 02/06/2006 03:30:00 13.9 1.8 18.7 9.9 13.8 1.9 17.9 9.5 43 6 49 305 31.5 1.8 35.9 19.3 02/06/2006 03:40:00 12.3 1.7 17.2 8.8 12.1 1.7 17.2 8.8 39 7 45 305 32 2 35.6 27.6 02/06/2006 03:50:00 13.5 1.7 17.9 10.3 13.2 1.7 18.3 9.9 33 7 38 305 31.7 1.5 34.6 27.9 02/06/2006 04:00:00 14.1 1.3 17.6 11.1 13.9 1.3 17.2 11.1 32 7 22 305 32.1 4 36.2 7.2 02/06/2006 04:10:00 13.8 1.5 17.6 10.3 13.5 1.4 17.2 9.9 31 6 29 305 32.5 1.8 35.3 18.4 02/06/2006 04:20:00 14.6 1.8 19.1 10.3 14.3 1.7 19.1 9.5 30 5 27 305 28.5 6.4 35.3 18.7 02/06/2006 04:30:00 13.4 1.8 19.1 9.9 13.4 1.7 18.3 9.1 37 6 37 305 45.2 12.3 52.9 15.9 02/06/2006 04:40:00 13.7 1.4 17.6 10.7 13.6 1.3 17.6 10.7 39 6 46 305 45 9.9 52.9 16.2 02/06/2006 04:50:00 14.3 1.6 18.7 10.7 14.3 1.6 18.7 10.3 38 6 40 305 30.2 14 52.9 17.9 02/06/2006 05:00:00 14.5 1.6 19.1 11.1 14.4 1.6 18.7 11.1 38 6 36 305 42.5 11.3 52.9 9.5 02/06/2006 05:10:00 14.1 1.9 19.5 9.1 14 1.9 18.7 8.8 37 6 39 305 33.2 14.6 52.9 19.3 02/06/2006 05:20:00 13.3 1.5 16.8 9.9 13.2 1.5 16.8 9.5 37 6 33 305 34.1 11.8 48.4 19.6 02/06/2006 05:30:00 12.9 1.7 17.9 8.4 12.7 1.7 17.2 8 28 8 20 305 44.7 9.9 52.9 19 02/06/2006 05:40:00 13.6 1.8 19.5 9.5 13.4 1.7 17.9 9.5 33 7 24 305 40.9 5.2 52.9 29.8 02/06/2006 05:50:00 12.7 1.7 17.9 9.1 12.6 1.6 16.8 9.1 28 8 32 305 35.6 4.2 38.6 17.9 02/06/2006 06:00:00 14 2.2 19.1 9.5 13.7 2 18.3 9.5 31 7 21 305 27.1 8.3 37.9 18.1 02/06/2006 06:10:00 12.9 1.9 17.9 8 12.7 1.9 17.6 7.2 30 8 31 305 36.2 7 42 19.3 02/06/2006 06:20:00 12.8 1.7 16.8 8.4 12.6 1.7 16.4 8 32 7 32 305 38.2 2.9 41.7 19.3 02/06/2006 06:30:00 12.8 1.5 17.6 9.5 12.6 1.5 16.4 9.1 34 7 39 305 37.7 3.4 40.6 18.7 02/06/2006 06:40:00 14 1.9 18.7 9.1 13.8 2 18.7 9.1 32 7 33 305 37.5 1.8 40.3 18.4 02/06/2006 06:50:00 14.1 1.7 19.1 10.3 13.9 1.7 18.7 9.1 29 7 21 305 37.5 2.2 40.6 18.1 02/06/2006 07:00:00 14.1 2.1 20.6 9.5 13.9 1.9 19.1 9.9 32 7 35 305 36.3 4.5 41.3 16.7 02/06/2006 07:10:00 13.4 1.8 19.1 9.9 13.1 1.8 19.1 9.1 33 7 35 305 37.7 2.9 41.7 18.1 02/06/2006 07:20:00 12.5 1.5 17.2 9.1 12.3 1.5 16.4 8.8 33 6 32 305 38 2.1 42 19.3 02/06/2006 07:30:00 13.2 2 17.9 8.8 13 1.8 17.2 8.4 26 7 22 305 30.6 9.1 44.1 17.9 02/06/2006 07:40:00 14.1 1.6 18.7 10.7 13.8 1.6 18.3 10.7 32 6 27 305 39.1 3.4 43.4 19.6 02/06/2006 07:50:00 12.7 1.6 17.6 9.1 12.5 1.5 16.4 9.1 32 7 39 305 36.7 5.9 41 19.9 02/06/2006 08:00:00 15.4 1.7 19.9 11.5 15 1.6 19.5 11.1 31 6 35 305 38.1 7.6 44.5 20.1 02/06/2006 08:10:00 16.3 2 21.8 12.2 15.8 2 21 10.7 34 6 27 305 34 9.9 52.9 20.1 02/06/2006 08:20:00 16.7 1.4 20.2 13.3 16.3 1.5 20.2 13 31 6 42 305 47 9.1 52.9 16.5 02/06/2006 08:30:00 15.2 1.3 18.7 11.8 14.9 1.5 19.1 11.8 32 6 24 305 36.8 4.4 50.6 17.9 02/06/2006 08:40:00 14.8 1.6 18.7 11.1 14.6 1.5 19.5 10.3 32 6 44 305 40 7.6 52.9 19.6 02/06/2006 08:50:00 15 1.7 19.5 11.1 14.6 1.5 19.1 10.7 28 6 25 305 36.5 3.1 39.3 19.9 02/06/2006 09:00:00 16.1 1.5 19.5 11.8 15.7 1.4 19.9 12.2 29 6 32 305 36.7 3.8 40.3 19.9 02/06/2006 09:10:00 14.6 1.5 18.7 11.1 14.3 1.6 18.7 10.3 29 6 23 305 36.5 4.2 40.3 20.1 02/06/2006 09:20:00 15.3 2 20.6 11.5 15 1.9 20.6 11.8 31 7 36 305 36.4 3.5 40.3 20.4 02/06/2006 09:30:00 15.2 2.5 21.4 10.7 15 2.4 21.8 11.1 36 6 35 305 35.7 5 40.3 20.4 02/06/2006 09:40:00 15.3 1.6 19.1 11.8 15.2 1.7 19.5 11.5 36 6 34 305 36.6 2.8 40.3 20.7 02/06/2006 09:50:00 14.9 1.7 19.9 9.9 14.7 1.7 19.1 11.1 32 5 31 305 36.2 3.5 39.6 20.7 02/06/2006 10:00:00 15.9 1.7 20.6 11.1 15.7 1.7 19.5 11.5 33 6 35 305 36 6.4 42 20.7 02/06/2006 10:10:00 14.6 1.3 17.9 11.1 14.4 1.3 17.6 11.5 30 6 32 305 37.3 2.6 40 20.7 02/06/2006 10:20:00 15.6 1.2 18.7 12.2 15.3 1.3 18.7 11.1 30 5 30 305 37.1 4.5 41.3 20.4 02/06/2006 10:30:00 16.3 1.7 21 11.1 15.9 1.7 20.2 10.3 29 6 32 305 37.2 2.2 40.6 21.3 02/06/2006 10:40:00 17 1.7 20.6 12.2 16.6 1.7 20.2 12.6 33 6 35 305 37.1 1 38.9 32.3 02/06/2006 10:50:00 18.6 1.9 22.9 13 18.2 2 22.9 13.3 35 6 30 305 36.2 5 42 21.3 02/06/2006 11:00:00 18.6 1.9 22.9 14.5 18.2 1.9 22.9 13.7 35 6 33 305 36.8 6.7 44.5 21.6 02/06/2006 11:10:00 16.9 2 21.4 12.6 16.6 2 21 10.7 31 8 30 305 30.3 7.6 43.8 21.6 02/06/2006 11:20:00 17.9 2.1 22.6 11.1 17.6 2.1 22.1 11.5 35 7 35 305 25.2 0.7 28.2 22.2 02/06/2006 11:30:00 15.7 1.8 19.9 9.9 15.5 1.8 19.5 8.8 36 8 48 305 39.8 7.3 48.1 24.6 02/06/2006 11:40:00 16.2 2.4 21.8 10.7 16 2.3 21.4 10.7 37 7 34 305 38.6 6.2 44.5 21.6 02/06/2006 11:50:00 15.8 1.7 19.9 12.2 15.6 1.7 19.9 11.5 41 6 52 305 36.5 6.7 45.5 22.2 02/06/2006 12:00:00 14.3 1.5 18.3 11.1 14.2 1.5 18.7 11.1 41 7 31 305 34.8 7.6 45.5 22.8 02/06/2006 12:10:00 14.9 1.7 20.6 11.1 14.6 1.8 20.2 9.5 42 7 36 305 42.1 5.2 47.3 23.1 02/06/2006 12:20:00 12.9 2.6 19.5 8 12.7 2.4 18.7 8 32 13 39 305 29.2 6.4 44.5 22.8 02/06/2006 12:30:00 11.2 1.3 15.3 8.4 11.1 1.3 15.6 8.4 16 5 18 305 28.5 1.4 31 24.3 02/06/2006 12:40:00 12.6 1.2 14.9 8.8 12.5 1.2 14.9 8.4 16 5 21 305 29 1.1 31.7 25.5 02/06/2006 12:50:00 12.5 1.2 15.3 9.5 12.3 1.2 15.3 9.5 17 4 17 305 42.5 6.4 48.1 26.7 02/06/2006 13:00:00 12.5 1.5 16.4 8.4 12.3 1.5 16.1 8 21 6 22 305 42.1 5.4 48.1 27 02/06/2006 13:10:00 12.9 1.5 16.4 9.9 12.7 1.5 16.4 9.5 24 5 30 305 44.5 1.8 47.7 28.2 02/06/2006 13:20:00 14.4 1.5 17.6 10.3 14.1 1.6 17.2 9.9 24 6 29 305 32.9 6.7 45.9 24.6 02/06/2006 13:30:00 14.4 1.7 17.6 9.5 14 1.7 17.6 9.5 30 5 32 305 28.9 1.3 32.3 24.9 02/06/2006 13:40:00 14 1.7 19.9 9.9 13.6 1.7 19.5 9.5 29 7 38 305 40.7 8.3 49.2 24.9 02/06/2006 13:50:00 13.6 1.2 16.8 10.7 13.4 1.3 17.6 10.3 28 7 26 305 43.6 4.7 48.4 24 02/06/2006 14:00:00 13.2 1.5 17.6 10.3 12.9 1.4 17.2 9.9 27 7 18 305 41.9 6.7 48.4 25.5 02/06/2006 14:10:00 12.8 1.5 16.8 9.5 12.4 1.4 16.8 9.5 26 7 23 305 38.3 8.7 49.2 24.9 02/06/2006 14:20:00 14.9 1.5 18.7 11.1 14.7 1.7 18.7 11.1 32 6 37 305 42.4 5.6 50.6 28.5 02/06/2006 14:30:00 14.9 1.7 19.5 10.3 14.6 1.6 20.6 10.7 29 7 48 305 44.7 6.7 52.5 29.8 02/06/2006 14:40:00 14.5 1.8 19.1 10.7 14.1 1.9 19.1 9.9 28 6 32 305 44.3 5 51.4 28.5 02/06/2006 14:50:00 15.3 1.8 20.2 11.5 15 1.7 20.6 11.1 28 6 21 305 36.8 0.8 38.6 31 02/06/2006 15:00:00 13.8 1.9 18.7 9.5 13.5 1.9 17.6 9.5 24 6 31 305 47.8 2.5 51 36.2 02/06/2006 15:10:00 13.8 1.5 18.3 10.3 13.6 1.6 17.9 9.9 24 6 26 305 46.5 4.2 51 34.3 02/06/2006 15:20:00 13.5 1.5 16.4 10.3 13.1 1.5 17.2 9.1 23 7 10 305 36.4 1 37.6 24.9 02/06/2006 15:30:00 12.6 1.5 15.6 8.8 12.4 1.3 15.6 9.1 21 6 29 305 41.4 7.3 52.9 25.8 02/06/2006 15:40:00 13.7 1.7 17.6 8.8 13.5 1.5 17.6 9.1 22 6 22 305 49.5 1.2 51.8 45.2 02/06/2006 15:50:00 13.5 1.6 17.6 9.1 13.4 1.5 17.2 9.1 22 5 18 305 42.5 7.3 50.6 -18.1 02/06/2006 16:00:00 13 1.6 16.4 9.5 12.9 1.6 16.8 9.5 19 6 16 305 35.6 8.7 52.9 24.6 02/06/2006 16:10:00 14.4 1.3 17.6 11.1 14.1 1.4 17.6 10.7 21 5 14 305 51.9 1.3 52.9 38.6 02/06/2006 16:20:00 13.3 1.3 16.4 9.9 13.1 1.3 16.1 9.5 22 6 18 305 38.8 2.1 52.1 31 02/06/2006 16:30:00 14.5 1.5 18.3 10.3 14.3 1.5 17.9 9.9 22 5 14 305 39 0.5 40.3 37.6 02/06/2006 16:40:00 14.4 1.5 17.9 10.7 14.3 1.6 17.9 9.5 24 6 17 305 39.4 1.2 40.6 21 02/06/2006 16:50:00 13.9 1.5 17.6 9.9 13.8 1.5 16.8 9.9 24 6 22 305 39.3 0.9 40.6 26.4 02/06/2006 17:00:00 15.2 1.3 19.1 11.5 15 1.3 19.9 11.8 26 5 26 305 45.2 7 52.9 37.6 02/06/2006 17:10:00 14.7 1.7 19.1 10.7 14.6 1.6 19.1 10.3 24 6 24 305 52 2.1 52.9 38.3 02/06/2006 17:20:00 13.7 1.7 18.3 9.5 13.4 1.7 18.3 10.3 27 6 27 305 50.9 3.8 52.9 40.3 02/06/2006 17:30:00 14.3 2 18.7 9.9 14.1 2.1 18.3 9.5 30 6 21 305 51.4 1.5 52.9 40 02/06/2006 17:40:00 16.1 1.4 19.1 12.6 15.7 1.4 19.1 12.6 28 6 31 305 52 0.6 52.9 49.5 02/06/2006 17:50:00 15.4 1.4 19.5 12.2 15.2 1.4 19.1 12.2 27 5 30 305 51.9 1.7 52.9 37.9 02/06/2006 18:00:00 16.2 1.5 20.2 12.2 15.9 1.5 19.5 11.5 26 5 26 305 43.6 6.4 52.9 33.3 02/06/2006 18:10:00 14.7 2 19.5 10.3 14.5 2 19.1 9.1 26 5 26 305 45.5 8 52.9 34.9 02/06/2006 18:20:00 14.9 1.5 18.7 11.1 14.7 1.5 18.7 10.7 27 5 30 305 51.9 2.8 52.9 39.6 02/06/2006 18:30:00 14.9 1.5 18.7 11.1 14.6 1.4 18.3 11.5 26 5 31 305 51.9 2.4 52.9 39.6 02/06/2006 18:40:00 13.7 1.4 17.2 10.3 13.5 1.5 16.8 8.8 22 6 18 305 52.5 1 52.9 40.6 02/06/2006 18:50:00 14.3 1.7 18.3 9.9 14.1 1.7 17.9 9.9 23 6 21 305 51.3 3.8 52.9 34.9 02/06/2006 19:00:00 14.5 1.3 17.6 11.1 14.2 1.4 17.9 11.1 22 5 23 305 44.1 7 52.9 34.9 02/06/2006 19:10:00 14.5 1.7 18.3 10.7 14.2 1.7 18.3 10.7 21 5 21 305 51.8 1.1 52.9 47.7 02/06/2006 19:20:00 14.2 1.4 17.2 10.3 13.9 1.5 16.8 9.9 22 6 19 305 41.8 4.2 52.9 34.3 02/06/2006 19:30:00 12.7 1.4 17.9 9.9 12.5 1.5 17.2 9.1 24 6 24 305 40.3 1.2 41.7 34.3 02/06/2006 19:40:00 12 1.2 14.9 8.8 11.7 1.3 15.3 8.8 25 6 23 305 40 1 41.3 34.3 02/06/2006 19:50:00 10.8 1 13.3 8.4 10.6 1 13.7 8.4 23 6 18 305 39.8 1.2 41.7 33.6 02/06/2006 20:00:00 11.6 1.4 14.9 8.4 11.5 1.3 14.1 8 29 5 32 305 39.6 0.8 41 33.6 02/06/2006 20:10:00 11.7 1.1 14.1 9.1 11.4 1.1 13.7 8.8 33 5 27 305 43.1 5.9 52.9 37.6 02/06/2006 20:20:00 11.1 0.8 13.3 9.1 10.8 0.8 12.6 8.8 30 5 23 305 52 2.5 52.9 37.2 02/06/2006 20:30:00 11.4 1.5 14.9 7.6 11.1 1.5 14.9 7.6 27 6 26 305 46.6 6.4 52.9 35.6 02/06/2006 20:40:00 12.3 1.3 15.3 9.5 12 1.4 15.3 8.8 29 6 27 305 51.3 1.8 52.9 38.3 02/06/2006 20:50:00 12.8 1.1 15.6 9.5 12.6 1 15.6 9.9 29 5 29 305 41.4 5.4 52.9 37.2 02/06/2006 21:00:00 13.5 1.1 15.6 10.7 13.4 1.2 16.1 10.7 22 5 27 305 48.4 6.4 52.9 37.2 02/06/2006 21:10:00 13.3 1 15.3 10.3 13.3 1 15.3 10.3 20 4 18 305 44.2 6.7 52.9 35.9 02/06/2006 21:20:00 13.4 0.9 16.1 11.1 13.1 0.9 15.6 10.3 22 4 21 305 36.7 0.2 37.2 35.9 02/06/2006 21:30:00 13.1 1.1 16.1 10.3 12.8 1.1 16.1 9.5 23 6 28 305 36.7 0.4 38.6 33.3 02/06/2006 21:40:00 14.3 1.3 17.6 11.1 14 1.3 17.9 10.7 27 6 23 305 36.9 0.4 37.9 35.6 02/06/2006 21:50:00 13.9 1.6 17.2 8.8 13.7 1.7 16.8 9.1 27 6 32 305 37.2 0.4 38.3 35.9 02/06/2006 22:00:00 12.8 1.5 15.6 8.8 12.6 1.5 16.4 9.1 32 5 31 305 44.1 7.3 52.9 36.2 02/06/2006 22:10:00 14.3 1.1 17.2 10.7 14.1 1.1 16.8 10.7 30 5 33 305 43.8 7 51.8 35.3 02/06/2006 22:20:00 14 1.3 17.2 10.3 13.7 1.3 16.4 9.5 28 5 28 305 45.8 4.5 50.6 36.2 02/06/2006 22:30:00 13 1 15.6 10.3 12.8 1.1 16.1 10.3 28 6 25 305 39.1 3.5 52.9 36.9 02/06/2006 22:40:00 13.9 1.1 16.4 10.7 13.6 1.2 16.4 10.7 25 5 22 305 51.2 2.1 52.9 37.2 02/06/2006 22:50:00 12.8 1.2 15.6 9.1 12.6 1.2 16.1 9.5 29 5 27 305 47.4 6.4 52.9 36.2 02/06/2006 23:00:00 12.7 1 14.9 9.9 12.5 1.1 14.9 9.1 30 5 37 305 48.6 3.7 52.5 36.6 02/06/2006 23:10:00 13.3 1.1 16.4 10.7 13.2 1.1 16.4 10.7 29 5 23 305 44.4 5.9 50.6 33.6 02/06/2006 23:20:00 14.1 1 16.1 11.5 13.7 1.1 16.1 10.7 30 5 29 305 37.2 0.6 38.3 28.5 02/06/2006 23:30:00 14.2 1.3 17.2 11.1 13.9 1.2 17.2 11.1 31 4 32 305 37.4 0.7 39.6 35.9 02/06/2006 23:40:00 15.4 1.1 18.3 12.2 15.1 1.1 17.9 11.5 26 5 22 305 37.3 0.5 38.3 35.9 02/06/2006 23:50:00 14.7 1.3 17.6 11.8 14.6 1.2 17.2 11.5 23 5 18 305 42 7.3 52.9 36.6 02/07/2006 00:00:00 14.8 1.4 17.9 11.5 14.6 1.3 17.2 11.5 28 5 23 305 42.9 7.6 52.9 35.6 02/07/2006 00:10:00 14.5 1.2 17.6 11.8 14.3 1.2 17.2 10.7 30 5 32 305 37.7 0.2 37.9 36.9 02/07/2006 00:20:00 12.2 1.2 16.1 8.8 12 1.3 15.6 8.8 27 6 32 305 36.7 1.2 37.9 31.4 02/07/2006 00:30:00 14 1.3 17.6 11.1 13.8 1.3 17.6 10.7 25 6 18 305 37.2 0.1 37.9 36.6 02/07/2006 00:40:00 15 1.6 18.3 10.7 14.8 1.5 18.7 10.3 27 5 29 305 37.5 0 37.9 37.2 02/07/2006 00:50:00 15.1 1.3 17.9 11.8 14.9 1.2 17.6 11.8 31 5 31 305 37.2 0 37.9 36.6 02/07/2006 01:00:00 15.7 1.1 18.3 13 15.4 1.2 17.9 12.6 32 4 31 305 37 0.1 37.6 36.6 02/07/2006 01:10:00 15.9 1 17.9 13 15.6 1.1 18.3 12.6 33 4 36 305 46.3 7.6 52.9 36.9 02/07/2006 01:20:00 14.8 1.2 17.6 11.5 14.6 1.3 17.6 11.1 36 5 37 305 52.1 2.3 52.9 36.6 02/07/2006 01:30:00 16.4 1.1 19.9 13 16.1 1.1 19.1 13 38 4 44 305 48.2 6.7 52.9 36.6 02/07/2006 01:40:00 15.8 1.3 19.1 13 15.6 1.4 19.1 12.6 39 5 36 305 51.8 2.9 52.9 36.6 02/07/2006 01:50:00 16.2 1.2 18.7 12.2 16 1.3 18.7 12.2 38 5 39 305 49.3 1.8 51 35.9 02/07/2006 02:00:00 15.9 1.2 18.7 12.6 15.7 1.3 19.1 12.2 38 5 40 305 42.1 6.4 49.9 35.3 02/07/2006 02:10:00 15.1 1.2 17.9 11.8 14.9 1.3 17.6 11.8 40 5 32 305 36.7 0.4 38.6 36.6 02/07/2006 02:20:00 15.7 1.5 18.7 11.8 15.5 1.5 18.7 11.5 41 5 40 305 36.4 0 36.6 36.2 02/07/2006 02:30:00 15 1.3 18.3 11.5 14.8 1.5 18.7 10.3 40 5 40 305 36.4 0 36.6 36.2 02/07/2006 02:40:00 15.1 1.4 17.9 11.5 14.8 1.4 17.9 11.1 38 5 37 305 36.4 0 36.9 36.2 02/07/2006 02:50:00 14.4 1.5 17.9 10.7 14.2 1.6 18.3 10.3 37 5 35 305 36.5 0 36.9 36.2 02/07/2006 03:00:00 14.1 1.5 17.6 10.3 13.9 1.6 17.9 10.3 40 6 43 305 36.6 0.1 36.9 36.6 02/07/2006 03:10:00 13.4 1.1 16.1 11.1 13.1 1.3 16.4 9.9 43 5 41 305 36.5 0 36.6 36.6 02/07/2006 03:20:00 13.4 1.3 16.4 10.3 13.3 1.3 16.4 9.9 43 5 40 305 37.2 2.1 45.9 29.5 02/07/2006 03:30:00 13.9 1 16.1 11.1 13.7 1.1 16.1 10.3 42 5 50 305 38.3 2.7 45.9 36.6 02/07/2006 03:40:00 12.4 1.2 14.9 9.9 12.3 1.2 15.6 9.9 40 5 39 305 37 1.7 45.9 28.8 02/07/2006 03:50:00 12.8 1 15.3 9.9 12.6 1.2 15.6 9.5 40 5 43 305 40.7 4 50.3 29.8 02/07/2006 04:00:00 12.7 1.2 15.6 9.1 12.5 1.3 15.3 9.9 40 5 38 305 42.3 4.7 51 30.4 02/07/2006 04:10:00 14 1.2 17.6 10.7 13.9 1.3 17.6 10.3 41 5 43 305 42.8 4.7 49.9 36.6 02/07/2006 04:20:00 13.8 1.2 16.8 10.3 13.5 1.3 16.8 10.3 39 5 39 305 37.9 4.7 48.8 26.1 02/07/2006 04:30:00 12.7 1 15.3 9.9 12.6 1.1 15.3 9.5 37 5 35 305 41.1 4 47.3 33.6 02/07/2006 04:40:00 11.6 1 14.1 9.1 11.4 1.1 14.5 8.8 36 5 38 305 38.6 4.5 46.3 25.8 02/07/2006 04:50:00 11.9 0.9 14.1 9.5 11.8 0.9 14.5 9.5 37 5 41 305 40.7 4.2 48.1 30.7 02/07/2006 05:00:00 11.1 1.2 14.1 8.8 11 1.3 14.5 8.4 39 5 35 305 43.3 3.4 48.4 35.3 02/07/2006 05:10:00 9.8 1.2 12.6 6.5 9.6 1.2 11.8 6.8 36 6 30 305 42.4 3.1 49.2 34.3 02/07/2006 05:20:00 10.6 1.1 13.3 8.4 10.3 1 13.7 8 31 5 32 305 42.2 3.1 48.4 33.6 02/07/2006 05:30:00 11.2 1 14.1 8.4 10.9 1.1 13.7 8.4 35 5 35 305 41.8 2.9 47.7 33.6 02/07/2006 05:40:00 10.6 1.3 13.3 7.2 10.4 1.4 13.3 7.2 26 6 25 305 41.4 4 48.4 33.6 02/07/2006 05:50:00 10.9 1 13.3 8.8 10.7 1 13.3 8 23 5 26 305 40.3 4.5 48.1 33 02/07/2006 06:00:00 10.7 0.9 13 8.4 10.4 0.9 13 8 24 5 29 305 41.3 4 48.1 33.6 02/07/2006 06:10:00 11.3 1 13.3 8.4 11.1 1 13.3 8.8 24 4 24 305 42.6 4 48.8 33.3 02/07/2006 06:20:00 9.4 1 12.2 7.2 9.2 1 11.5 7.2 27 5 35 305 43.5 3.8 48.4 33.6 02/07/2006 06:30:00 10.1 0.8 12.2 8 10 0.8 12.2 7.6 31 5 33 305 42.6 3.7 47.7 32.3 02/07/2006 06:40:00 10.2 0.9 12.2 7.2 10 0.9 12.2 7.6 30 5 33 305 41.1 3.2 45.5 31.7 02/07/2006 06:50:00 9.4 0.9 11.1 7.2 9.3 0.9 11.5 6.5 32 5 35 305 40.4 3.2 44.8 32 02/07/2006 07:00:00 10.4 1 12.6 7.2 10.2 1.1 12.2 6.8 34 5 38 305 40.1 3.2 44.8 31.4 02/07/2006 07:10:00 8.9 0.9 11.1 6.8 8.8 1 11.1 6.8 30 6 36 305 39.1 3.5 44.8 25.5 02/07/2006 07:20:00 8.6 0.7 10.3 6.8 8.5 0.7 10.7 6.5 28 5 27 305 39.1 3.5 43.8 30.7 02/07/2006 07:30:00 9.1 1.3 13 6.8 8.9 1.2 13 6.8 28 6 22 305 39.1 3.2 43.8 31.7 02/07/2006 07:40:00 7.7 0.9 11.1 5.7 7.5 0.8 10.3 5.7 28 7 33 305 38.5 3.7 43.1 30.4 02/07/2006 07:50:00 8 0.7 9.9 6.1 7.9 0.8 9.9 6.1 29 7 27 305 40.9 3.1 44.5 26.7 02/07/2006 08:00:00 7.8 0.9 10.3 5.7 7.6 0.9 10.7 4.9 34 6 44 305 41.5 3.2 45.9 26.4 02/07/2006 08:10:00 8.5 1 10.7 6.1 8.3 1 10.7 5.7 32 5 31 305 41.4 3.1 46.3 32.6 02/07/2006 08:20:00 9.1 1 11.8 6.8 8.9 1 11.5 6.5 33 5 36 305 39.9 3.4 44.5 31.4 02/07/2006 08:30:00 9 1 11.1 6.5 8.8 1 11.5 6.1 32 5 36 305 40.6 4.2 47.7 24.9 02/07/2006 08:40:00 8 1 10.3 5.7 7.9 1 10.3 5.7 32 6 36 305 42.5 2.6 45.9 33.3 02/07/2006 08:50:00 7.9 0.9 9.9 5.7 7.8 0.9 9.9 5.7 20 6 19 305 41.9 3.1 45.5 32 02/07/2006 09:00:00 9.1 0.9 10.7 6.8 8.9 0.8 11.1 6.8 16 4 16 305 42.1 4 45.9 27 02/07/2006 09:10:00 7.9 1.3 10.7 4.9 7.8 1.3 10.7 4.9 17 5 19 305 42.9 2.3 48.8 30.7 02/07/2006 09:20:00 7.6 0.7 9.5 5.7 7.5 0.7 9.1 5.7 23 6 15 305 44 4.5 52.5 34.3 02/07/2006 09:30:00 7.6 0.7 9.1 5.7 7.5 0.7 9.1 5.7 25 5 22 305 48.8 2.9 52.9 33.6 02/07/2006 09:40:00 6.6 0.7 8.8 4.9 6.5 0.6 8.4 4.9 26 5 31 305 39.5 7.6 48.8 26.7 02/07/2006 09:50:00 7 0.6 8.4 5.3 6.8 0.6 8.4 4.9 25 5 25 305 40.9 8.3 50.6 27.6 02/07/2006 10:00:00 6.9 0.7 8.4 4.6 6.8 0.7 8.4 4.2 25 5 32 305 41.5 6.2 52.1 27 02/07/2006 10:10:00 6.4 0.8 8 4.2 6.2 0.9 8 4.2 23 5 21 305 50 2.1 52.9 44.8 02/07/2006 10:20:00 6.4 0.6 8 4.6 6.2 0.6 7.6 4.6 24 4 17 305 42.5 5.4 51 27.3 02/07/2006 10:30:00 6.3 0.6 7.6 4.6 6.1 0.6 7.2 4.9 24 5 25 305 37 5 46.3 27.3 02/07/2006 10:40:00 6.6 0.6 8.4 5.3 6.4 0.6 7.6 4.9 23 4 21 305 42.8 4 45.9 28.2 02/07/2006 10:50:00 6 0.7 7.6 4.2 5.9 0.7 7.2 3.8 22 5 23 305 43.7 0.8 45.5 37.2 02/07/2006 11:00:00 5.5 0.7 7.2 3.8 5.3 0.7 7.2 3.8 28 5 27 305 41.1 1.8 43.8 26.4 02/07/2006 11:10:00 6 0.5 7.2 4.6 5.9 0.5 6.8 4.2 28 6 24 305 32.4 6.7 43.1 26.1 02/07/2006 11:20:00 6.3 0.6 8 4.6 6.2 0.7 8 4.6 37 5 39 305 29.5 1.1 31.7 26.7 02/07/2006 11:30:00 6.8 0.6 8 5.3 6.7 0.7 8 4.6 39 4 35 305 29.9 1.1 32 27.6 02/07/2006 11:40:00 6.1 0.6 7.2 4.2 5.9 0.6 6.8 4.2 39 5 37 305 30.4 1 32 27.9 02/07/2006 11:50:00 5.1 0.5 6.1 3.8 4.9 0.5 6.1 3.8 38 5 52 305 45.4 7.3 51.4 28.8 02/07/2006 12:00:00 4.5 0.5 5.7 3.4 4.3 0.6 5.7 3 37 5 36 305 46.9 2.1 49.9 29.2 02/07/2006 12:10:00 3.7 0.4 4.6 2.6 3.4 0.5 4.6 2.3 42 6 42 305 40.7 6.7 51 28.8 02/07/2006 12:20:00 3.9 0.5 5.3 2.6 3.7 0.5 4.9 2.3 44 5 46 305 36.5 1.2 40.6 29.8 02/07/2006 12:30:00 4.1 0.5 5.3 3 3.9 0.5 4.9 2.6 43 6 43 305 35.8 0.7 37.6 31 02/07/2006 12:40:00 4.2 0.4 5.3 3 4 0.4 4.9 3 48 5 50 305 35.7 1.8 37.9 27.3 02/07/2006 12:50:00 4.4 0.4 5.3 3.4 4.2 0.4 5.3 3.4 46 6 46 305 41.1 4.5 50.3 32.6 02/07/2006 13:00:00 4.3 0.4 5.7 3 4.2 0.5 5.3 3 45 5 49 305 43 3.7 49.9 36.6 02/07/2006 13:10:00 4.4 0.4 5.3 3.4 4.2 0.5 5.3 3 48 6 50 305 48.9 3.5 52.9 35.6 02/07/2006 13:20:00 4.5 0.4 5.3 3.4 4.3 0.4 5.3 3.4 49 4 46 305 47.1 3.8 51.4 33.3 02/07/2006 13:30:00 3.7 0.4 4.9 2.6 3.6 0.4 4.6 2.3 51 6 48 305 43.5 6.4 51.8 29.5 02/07/2006 13:40:00 5.3 0.6 6.5 2.6 5.1 0.7 6.1 2.6 60 4 60 305 37.6 1.5 40.3 28.8 02/07/2006 13:50:00 5.6 0.5 6.5 3.4 5.3 0.5 6.5 3.4 61 7 60 305 35.2 3.5 39.6 28.5 02/07/2006 14:00:00 6.7 0.6 8 4.9 6.1 0.6 7.2 4.2 80 6 78 305 36.7 2.7 39.6 28.5 02/07/2006 14:10:00 5.3 0.8 8 3.4 4.9 0.9 8.4 3 79 10 65 305 36.7 1.2 38.6 28.2 02/07/2006 14:20:00 4.4 1 6.5 1.5 4.1 0.9 6.5 1.5 78 19 42 305 45.9 5.4 51.8 33.3 02/07/2006 14:30:00 4.6 1.6 7.2 1.9 4.2 1.7 7.2 1.5 58 12 70 305 44.9 5.9 51 28.5 02/07/2006 14:40:00 5.3 0.9 7.6 3 5.1 0.9 7.2 3 62 8 73 305 41.4 6.4 49.9 27.9 02/07/2006 14:50:00 5.8 0.7 7.6 3.8 5.4 0.6 7.2 3.8 69 8 77 305 36.2 1.5 42.4 27.3 02/07/2006 15:00:00 5.8 0.6 7.2 3.8 5.5 0.7 7.2 3 64 8 63 305 38.9 5 47 26.7 02/07/2006 15:10:00 4.7 0.7 6.5 2.6 4.4 0.8 6.1 2.3 63 8 78 305 42.4 3.2 45.2 27.3 02/07/2006 15:20:00 4.6 0.6 6.1 3 4.2 0.7 6.1 2.3 50 9 58 305 32.4 5.9 44.8 27.6 02/07/2006 15:30:00 4.1 0.8 5.7 2.3 3.9 0.8 5.3 2.3 47 8 56 305 36.3 8 48.8 28.2 02/07/2006 15:40:00 3.4 0.5 4.6 2.3 3.1 0.6 4.6 1.9 43 8 59 305 40.1 6.2 48.8 28.2 02/07/2006 15:50:00 4.6 1.4 6.5 1.9 4.2 1.5 6.5 1.5 53 8 54 305 42.8 6.2 47.7 28.5 02/07/2006 16:00:00 5.6 0.5 6.8 4.2 5.4 0.6 6.8 4.2 57 6 62 305 42.5 3.8 46.3 28.2 02/07/2006 16:10:00 5.7 0.5 7.2 4.2 5.3 0.6 6.8 3.8 68 8 70 305 37.3 9.5 47 -14.6 02/07/2006 16:20:00 6 0.9 8.4 3.8 5.4 0.8 7.6 3 75 9 74 305 37.1 2.9 41.3 22.5 02/07/2006 16:30:00 6.9 0.9 9.5 4.6 6.2 0.8 8.4 4.2 89 8 94 305 40.6 5.9 52.1 23.4 02/07/2006 16:40:00 5.6 1.3 8.4 2.6 5.1 1.1 7.2 2.3 75 21 87 305 48.5 8.3 52.9 -16.9 02/07/2006 16:50:00 5.9 1.8 8.8 1.9 5.4 1.5 7.6 1.1 68 24 90 305 44.2 4.4 52.9 35.3 02/07/2006 17:00:00 7.6 0.7 9.1 5.7 6.8 0.6 8.4 4.9 89 5 93 305 49.3 5.2 52.9 38.6 02/07/2006 17:10:00 8.3 0.6 9.9 6.5 7.5 0.6 8.8 6.1 91 5 92 305 50.7 2.1 52.9 37.6 02/07/2006 17:20:00 8.8 0.6 10.3 6.5 8 0.5 9.5 6.5 92 5 92 305 48.8 4.2 52.9 23.4 02/07/2006 17:30:00 8.9 0.6 10.3 7.2 7.9 0.6 9.5 6.5 96 3 99 305 50.1 2.6 52.9 35.3 02/07/2006 17:40:00 8.4 0.7 10.3 6.8 7.6 0.6 9.1 6.1 94 5 100 305 49.3 4.7 52.9 -2.7 02/07/2006 17:50:00 8.1 0.8 9.9 6.5 7.4 0.7 9.1 5.7 88 5 92 305 50.3 4 52.9 37.9 02/07/2006 18:00:00 7.7 0.6 9.1 6.1 6.9 0.5 8 5.3 92 4 95 305 50.1 3.8 52.9 37.6 02/07/2006 18:10:00 7.4 0.5 8.8 5.7 6.5 0.5 7.6 4.9 92 4 96 305 50.2 4.2 52.9 37.9 02/07/2006 18:20:00 7.4 0.6 8.8 6.1 6.7 0.6 8 5.3 100 6 104 305 51.4 0.6 52.9 49.5 02/07/2006 18:30:00 7.4 0.7 9.1 5.3 6.8 0.6 8.4 4.9 99 5 110 305 51 0.8 52.9 49.2 02/07/2006 18:40:00 7.4 0.5 8.8 6.1 6.6 0.4 7.6 5.7 97 3 95 305 50.5 0.8 52.9 48.8 02/07/2006 18:50:00 7.7 0.5 8.8 6.5 6.8 0.5 7.6 5.3 97 3 95 305 46.7 4.2 52.1 36.9 02/07/2006 19:00:00 7.6 0.5 8.8 6.1 7 0.5 8 5.7 102 3 103 305 48.4 3.7 52.9 39.6 02/07/2006 19:10:00 7.5 0.6 8.8 5.7 7.1 0.6 8.4 5.7 107 5 108 305 51.8 1.4 52.9 37.2 02/07/2006 19:20:00 7.4 0.5 8.8 6.1 7.2 0.5 8.4 5.7 116 5 106 305 48.5 1.7 51.8 34.3 02/07/2006 19:30:00 6.5 0.6 7.6 4.6 6.5 0.6 8 4.9 123 6 124 305 46.4 3.5 52.9 33.3 02/07/2006 19:40:00 7 0.7 8.4 4.9 6.7 0.7 8 4.9 132 5 127 305 48.9 4.5 52.9 33.9 02/07/2006 19:50:00 7.7 0.6 8.8 5.7 7.2 0.5 8 5.3 139 4 143 305 48.8 4 52.9 18.4 02/07/2006 20:00:00 8.3 0.4 9.1 7.2 7.8 0.4 9.1 6.5 141 2 145 305 49.2 4.7 52.9 -2.4 02/07/2006 20:10:00 8.5 0.4 9.5 7.6 8 0.3 8.8 7.2 143 2 145 305 48.1 4.2 52.9 19 02/07/2006 20:20:00 8.4 0.4 9.5 7.6 8.1 0.3 8.8 7.2 145 2 143 305 48.2 1.5 52.9 43.1 02/07/2006 20:30:00 7.8 0.4 9.1 6.5 7.6 0.3 8.4 6.8 146 3 146 305 48.2 1 50.3 44.5 02/07/2006 20:40:00 7.2 0.5 8.4 5.7 7 0.5 8 6.1 146 2 145 305 48.2 2.4 52.1 33.3 02/07/2006 20:50:00 6.7 0.3 7.2 4.9 6.5 0.3 7.2 5.7 146 3 154 305 47.8 2.2 51 30.1 02/07/2006 21:00:00 6.4 0.5 7.6 3.8 6.3 0.4 7.2 5.3 147 5 139 305 47.7 2.1 51 27.3 02/07/2006 21:10:00 6.5 0.6 8 4.2 6.4 0.5 7.6 5.3 145 5 154 305 47.1 1.5 49.9 30.1 02/07/2006 21:20:00 6.5 0.4 7.2 5.3 6.3 0.2 6.8 5.7 143 3 141 305 46.5 1.1 49.5 39.3 02/07/2006 21:30:00 5.9 0.6 6.8 4.2 6.2 0.4 6.8 4.9 146 6 143 305 46.5 1.1 49.2 43.8 02/07/2006 21:40:00 6.1 0.5 7.2 4.2 6.3 0.4 7.2 4.9 146 5 145 305 46.6 0.8 48.4 44.8 02/07/2006 21:50:00 5.6 0.7 7.2 3.8 6 0.4 6.8 4.9 151 6 149 305 46.6 1.4 49.2 28.5 02/07/2006 22:00:00 5.4 0.5 6.5 3.4 6 0.4 6.8 3.8 150 6 142 305 46.6 1 48.8 45.2 02/07/2006 22:10:00 5.2 0.7 6.5 3.4 5.6 0.5 6.5 4.2 154 5 151 305 46.4 0.9 48.8 45.2 02/07/2006 22:20:00 4.5 0.5 6.1 2.6 4.9 0.4 6.1 4.2 157 5 158 305 45.5 1.9 48.8 34.9 02/07/2006 22:30:00 4.1 0.6 5.7 2.3 4.7 0.4 5.7 3.4 155 8 152 305 45.8 0.8 48.4 44.5 02/07/2006 22:40:00 3.3 0.7 5.3 1.5 4.8 0.4 5.7 3.4 173 8 183 305 46.1 1 48.4 43.4 02/07/2006 22:50:00 3.4 0.7 4.9 1.5 4.1 0.4 5.3 3 181 5 184 305 46.1 0.9 47.7 44.8 02/07/2006 23:00:00 3.1 0.8 5.7 1.9 4.2 0.5 5.7 2.6 175 7 188 305 46 1 47.7 44.5 02/07/2006 23:10:00 4.2 0.5 5.3 2.6 4.3 0.4 5.3 3.8 154 5 152 305 45.3 2.7 50.6 34.9 02/07/2006 23:20:00 3.9 0.5 5.3 2.3 4.4 0.2 5.3 3.8 161 3 168 305 47.7 2.1 51 36.2 02/07/2006 23:30:00 4.5 0.2 5.3 3.8 4.9 0.2 5.3 4.2 146 5 155 305 46.8 0.7 48.4 45.5 02/07/2006 23:40:00 4.5 0.5 5.3 1.9 5.1 0.5 6.1 4.2 154 4 151 305 46.7 0.8 48.1 45.2 02/07/2006 23:50:00 4.7 0.6 5.7 3 5.2 0.4 6.1 4.2 151 5 148 305 45.9 2.8 48.8 34.6 02/08/2006 00:00:00 5.5 0.6 6.8 4.6 5.4 0.4 6.5 4.2 144 3 141 305 46.3 1.1 48.1 37.6 02/08/2006 00:10:00 6.3 0.5 7.6 4.6 6.2 0.7 7.2 4.2 142 3 140 305 46.2 1.5 48.1 37.2 02/08/2006 00:20:00 6.9 0.8 8 3 6.9 0.5 7.6 4.6 147 5 158 305 45.6 1.6 47.7 34.3 02/08/2006 00:30:00 6.7 0.5 8 4.6 7.2 0.3 7.6 6.1 151 3 155 305 45.7 1.2 49.2 36.6 02/08/2006 00:40:00 6.7 0.4 7.6 4.9 6.9 0.2 7.6 6.5 154 3 154 305 46 1.5 48.8 37.9 02/08/2006 00:50:00 6.4 0.9 8 3.4 6.7 0.6 7.6 4.6 152 5 155 305 45.9 1.3 48.8 30.7 02/08/2006 01:00:00 6.8 0.8 8 3.4 7 0.4 8 4.9 153 4 158 305 45.5 1.6 49.2 31 02/08/2006 01:10:00 7.7 0.5 8.8 5.3 7.5 0.3 8 6.5 153 3 154 305 45.5 0.8 47.7 44.1 02/08/2006 01:20:00 7.2 0.7 8.4 3.4 7.2 0.4 8 5.3 151 5 163 305 45.1 0.8 46.6 43.8 02/08/2006 01:30:00 6.7 0.7 7.6 3.4 7 0.3 8 5.7 151 5 148 305 42.2 3.8 45.9 32.6 02/08/2006 01:40:00 6.5 0.5 7.2 4.2 6.7 0.3 7.6 5.7 150 4 151 305 40.6 3.2 45.2 33.9 02/08/2006 01:50:00 5.8 0.8 6.8 3 6.3 0.4 7.2 4.2 151 6 150 305 41.3 3.7 46.3 5.4 02/08/2006 02:00:00 5.1 0.8 6.5 1.9 6 0.5 6.8 3.8 154 6 155 305 45.2 3.1 51 30.7 02/08/2006 02:10:00 3.9 1.3 6.8 0.4 4.3 1.5 6.8 0.7 148 14 148 305 43.4 2.7 48.8 31.7 02/08/2006 02:20:00 5.7 1 7.6 2.6 5.8 0.9 7.2 3 141 9 143 305 41.1 3.7 45.5 31.7 02/08/2006 02:30:00 3.2 1.3 6.1 0.4 3.3 1.2 5.7 0.4 129 29 105 305 41.5 5.9 50.3 19.9 02/08/2006 02:40:00 2.2 1.5 6.1 0.4 1.7 1.4 5.3 0.4 74 66 142 305 44.2 3.7 51 19.6 02/08/2006 02:50:00 0.9 0.8 3 0.4 1 0.9 3.4 0.4 355 53 50 305 44.3 5.4 47.7 -19.5 02/08/2006 03:00:00 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 30 15 19 305 46.1 1.2 47.7 28.2 02/08/2006 03:10:00 1 0.5 2.3 0.4 1.1 0.6 3 0.4 24 9 51 305 46.5 0.9 48.8 43.8 02/08/2006 03:20:00 1.9 0.5 3.4 1.1 2.3 0.6 3.4 1.1 16 8 26 305 45.9 0.6 47.3 44.1 02/08/2006 03:30:00 1.6 0.8 2.6 0.4 2.1 0.7 3 0.4 39 14 17 305 45.8 0.5 47 44.5 02/08/2006 03:40:00 0.6 0.3 1.5 0.4 0.8 0.5 2.3 0.4 69 12 65 305 46.3 2.7 50.6 16.7 02/08/2006 03:50:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 113 64 87 305 46.3 0.4 48.4 44.5 02/08/2006 04:00:00 0.9 0.5 2.6 0.4 0.6 0.4 2.3 0.4 351 66 17 305 46.4 2.4 49.5 29.5 02/08/2006 04:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 335 64 184 305 46.3 2.4 49.9 19 02/08/2006 04:20:00 1.7 0.6 3 0.4 1.8 0.7 3.4 0.4 5 28 38 305 45.9 0.5 48.1 44.8 02/08/2006 04:30:00 1.8 0.7 3.4 0.4 1.7 0.7 3.4 0.4 34 21 30 305 45.5 0.2 47 45.2 02/08/2006 04:40:00 2.7 1 4.6 0.4 3 1 4.6 0.4 28 24 57 305 44.9 0.2 47 44.5 02/08/2006 04:50:00 3.2 0.9 5.3 1.1 2.9 1.1 5.3 0.4 31 18 27 305 45 3.5 48.4 17 02/08/2006 05:00:00 4.7 0.8 6.5 2.3 5 0.8 7.6 3 19 12 35 305 45.3 3.4 49.5 17.6 02/08/2006 05:10:00 4.6 1.5 8.4 0.4 4.6 1.7 8 0.4 17 27 36 305 46.1 3.5 51 17.9 02/08/2006 05:20:00 3.2 1.2 6.5 0.4 3.8 1.2 7.2 0.4 355 26 21 305 47 3.4 51.4 34.3 02/08/2006 05:30:00 4.3 1.1 6.8 1.9 4.7 1.1 8.8 2.6 9 22 11 305 44.7 1 46.6 34.6 02/08/2006 05:40:00 4.8 0.9 6.5 1.9 5.1 0.7 6.8 2.3 30 9 28 305 44.2 0.4 44.8 43.1 02/08/2006 05:50:00 5.1 1.3 7.6 0.4 5.4 1.3 8 0.4 6 17 12 305 44.6 0 45.2 44.1 02/08/2006 06:00:00 5.2 1.4 8.4 1.5 5.7 1.3 8.8 0.7 15 17 30 305 44.1 1.8 45.9 15.3 02/08/2006 06:10:00 6.2 0.6 7.6 4.6 6.6 0.5 8 4.9 28 6 27 305 42.9 0.7 44.5 41.3 02/08/2006 06:20:00 6.5 0.4 8 4.9 6.8 0.4 8 5.7 26 5 35 305 43.8 1.5 45.9 39.3 02/08/2006 06:30:00 5.5 0.9 7.6 3 5.8 0.8 7.6 3.8 16 12 27 305 41.2 3.4 45.2 35.6 02/08/2006 06:40:00 5.3 0.7 7.2 3.8 5.6 0.7 7.2 3.8 15 10 40 305 34.7 1.4 36.9 28.8 02/08/2006 06:50:00 4.3 1 6.8 1.9 4.5 1 7.2 2.3 6 13 25 305 37.2 7.3 45.2 -18.1 02/08/2006 07:00:00 5 1 8.4 2.3 5.3 1 8 1.9 4 11 347 305 40.6 6.7 49.9 -17.7 02/08/2006 07:10:00 6.7 0.9 9.1 4.6 7 0.8 9.1 4.6 5 9 358 305 40.3 4.7 45.9 18.4 02/08/2006 07:20:00 6.6 0.7 8.4 4.6 6.2 0.7 8.4 4.6 39 18 9 305 44.2 4 51.8 20.4 02/08/2006 07:30:00 8.3 0.9 9.9 5.3 7.6 1 9.1 4.6 62 5 59 305 46.9 3.2 51.4 20.4 02/08/2006 07:40:00 7.7 0.9 9.5 5.7 7.3 0.8 9.1 5.7 55 7 64 305 40.7 4.4 47.7 31.7 02/08/2006 07:50:00 5.7 0.3 6.8 4.9 5.5 0.4 6.8 4.6 26 7 35 305 43.7 3.2 48.8 14 02/08/2006 08:00:00 5.2 0.3 5.7 4.6 5.1 0.3 5.7 4.2 14 3 19 305 44.8 1.8 48.1 33.6 02/08/2006 08:10:00 5.8 0.4 6.8 4.9 5.7 0.4 6.8 4.9 6 4 8 305 45.7 3.8 50.3 17.6 02/08/2006 08:20:00 6.5 0.5 7.6 4.9 6.3 0.6 7.6 4.9 6 6 9 305 45.4 2.5 49.5 31 02/08/2006 08:30:00 5.8 0.5 7.2 4.6 5.9 0.5 6.8 4.2 13 7 32 305 45.2 1.9 48.1 34.6 02/08/2006 08:40:00 5.9 0.8 7.6 3.4 5.8 0.8 7.6 3.4 24 9 33 305 44.7 1.8 47.7 32.3 02/08/2006 08:50:00 3.9 1 6.5 1.1 3.8 1.2 6.1 0.7 23 30 18 305 45.9 1.7 48.8 33.9 02/08/2006 09:00:00 3 0.7 4.6 1.1 2.9 0.8 4.9 0.7 9 18 5 305 45.5 2.4 48.4 32.6 02/08/2006 09:10:00 3.8 1.1 6.1 1.1 3.4 1 6.1 1.5 78 29 80 305 44.8 2.3 47.7 32.6 02/08/2006 09:20:00 4.6 0.9 6.8 1.9 4.1 0.8 6.5 1.9 87 19 105 305 43.3 1.4 45.2 31.7 02/08/2006 09:30:00 4.2 0.8 6.1 2.3 4.1 0.8 5.7 2.3 45 21 33 305 39.9 3.4 44.5 16.5 02/08/2006 09:40:00 5 0.5 6.1 3.4 5.2 0.5 6.1 3.4 22 5 24 305 41.8 2.4 44.8 31.7 02/08/2006 09:50:00 4.5 0.6 5.7 3 4.3 0.6 5.7 3 42 13 33 305 41.6 1.5 44.5 29.5 02/08/2006 10:00:00 5.3 1 8.8 3 4.9 0.9 8 3 67 22 101 305 42.5 2.4 45.2 32.6 02/08/2006 10:10:00 7.1 0.6 9.1 5.3 6.6 0.6 8.8 4.9 91 7 92 305 37.8 5.6 46.6 15.6 02/08/2006 10:20:00 6.9 1 8.8 4.2 6.5 0.9 9.1 3.8 90 9 84 305 34.3 5.4 46.6 3.2 02/08/2006 10:30:00 4.8 0.9 7.6 3 4.4 1 7.6 2.6 79 12 82 305 43 3.1 46.6 12.9 02/08/2006 10:40:00 3.4 0.6 5.7 2.3 3.2 0.6 5.3 1.9 51 17 87 305 42.4 2.3 45.5 24.3 02/08/2006 10:50:00 2.9 0.3 3.8 1.9 2.7 0.3 3.4 1.9 40 7 48 305 46.2 2.3 49.9 37.9 02/08/2006 11:00:00 3.1 0.3 3.8 2.3 3 0.3 3.8 2.3 29 6 32 305 45.5 2.9 49.5 37.2 02/08/2006 11:10:00 3.2 0.3 3.8 2.3 3 0.4 3.8 2.3 37 7 32 305 47.8 2.6 52.9 33.9 02/08/2006 11:20:00 4.5 1.2 7.6 2.3 4.3 1.2 7.2 2.3 66 15 93 305 46.5 2.6 50.3 30.1 02/08/2006 11:30:00 5.8 0.6 8 4.2 5.6 0.6 7.6 4.2 83 9 80 305 47.7 1.1 50.6 44.5 02/08/2006 11:40:00 5.5 0.7 7.6 3.4 5.3 0.7 7.2 3.8 84 9 80 305 43.4 6.7 48.8 -10.9 02/08/2006 11:50:00 5.6 0.9 7.6 3.4 5.6 0.9 8 3.4 89 11 88 305 43.1 5 48.4 30.1 02/08/2006 12:00:00 5.8 0.8 8.4 3.8 5.8 0.8 8 3.8 89 12 80 305 39.3 4.7 45.5 29.8 02/08/2006 12:10:00 5.1 0.7 7.6 3.4 5.1 0.7 6.8 3.4 94 11 97 305 42.3 2.2 45.2 32.3 02/08/2006 12:20:00 4.7 0.6 6.5 2.6 4.7 0.6 6.1 2.6 92 11 98 305 40.6 4.4 44.5 27.3 02/08/2006 12:30:00 4.8 0.4 6.5 3.8 4.9 0.4 6.1 3.4 88 6 87 305 37.5 4.7 44.1 30.1 02/08/2006 12:40:00 3.1 1.5 5.7 0.4 2.9 1.6 5.7 0.4 54 30 78 305 35.9 4.7 44.8 28.8 02/08/2006 12:50:00 1.9 1.1 4.6 0.7 1.7 1.2 4.2 0.4 35 33 83 305 37.7 2.8 43.1 27.6 02/08/2006 13:00:00 4.3 0.6 5.7 2.6 4.2 0.6 5.7 2.6 84 6 75 305 36.3 1.9 39.3 27.6 02/08/2006 13:10:00 5.6 0.5 6.5 4.2 5.5 0.5 6.5 4.2 79 4 77 305 36.3 2.7 39.6 23.4 02/08/2006 13:20:00 6.1 0.3 6.8 4.9 5.8 0.3 6.5 4.9 78 3 78 305 34.1 2.5 39.6 21.3 02/08/2006 13:30:00 5.7 0.3 6.5 4.9 5.4 0.3 6.8 4.6 73 3 78 305 32.2 1.6 35.9 24.9 02/08/2006 13:40:00 5.5 0.2 6.1 4.9 5.2 0.2 5.7 4.6 72 2 76 305 31 1.6 34.3 21 02/08/2006 13:50:00 5.8 0.2 6.5 4.9 5.4 0.2 6.1 4.6 74 3 73 305 31.3 3.1 36.2 20.7 02/08/2006 14:00:00 6 0.2 6.5 5.3 5.5 0.2 6.1 4.9 75 3 73 305 34.9 1 37.2 30.4 02/08/2006 14:10:00 5.8 0.3 6.5 4.9 5.4 0.3 6.1 4.6 76 3 78 305 34.6 0.9 36.6 32.3 02/08/2006 14:20:00 5.8 0.3 6.5 4.9 5.3 0.3 6.1 4.6 79 3 80 305 31.2 1.9 34.9 25.2 02/08/2006 14:30:00 5.9 0.3 6.8 4.9 5.5 0.3 6.5 4.6 79 4 82 305 32.9 0.7 33.9 25.8 02/08/2006 14:40:00 6.4 0.5 7.6 5.3 5.9 0.5 7.2 4.9 83 5 86 305 32.6 1 34.3 28.2 02/08/2006 14:50:00 6.5 0.5 8 4.6 6 0.5 7.6 4.9 85 5 88 305 31.4 2.6 34.3 25.5 02/08/2006 15:00:00 6.1 0.6 7.6 3.8 5.4 0.5 6.8 3.8 88 6 85 305 26.2 0.9 27.6 20.4 02/08/2006 15:10:00 6.3 0.5 8 4.2 5.6 0.5 6.8 4.2 84 5 78 305 26.4 0.2 27.3 24.9 02/08/2006 15:20:00 5.8 0.5 6.8 4.9 5.2 0.4 6.5 4.2 85 5 83 305 26.6 0.1 27.3 26.4 02/08/2006 15:30:00 5.8 0.8 7.6 3.8 5.3 0.8 6.8 3.8 82 6 78 305 26.8 0.4 27.6 25.2 02/08/2006 15:40:00 6.5 0.6 8.4 5.3 5.9 0.5 8 4.9 81 5 78 305 26.5 1.4 28.5 3.4 02/08/2006 15:50:00 6.2 0.4 7.2 4.9 5.7 0.4 6.5 4.6 81 4 80 305 27.4 0.9 29.2 13.4 02/08/2006 16:00:00 5.8 0.5 6.8 4.6 5.3 0.5 6.5 4.2 80 5 73 305 28.4 0.2 29.5 27.6 02/08/2006 16:10:00 5.5 0.5 6.8 4.6 5 0.4 6.1 3.8 73 5 73 305 29.2 0.6 30.7 28.2 02/08/2006 16:20:00 6 0.4 7.2 4.9 5.4 0.4 6.5 4.6 71 5 67 305 29.1 1 31 17.3 02/08/2006 16:30:00 6.1 0.5 7.2 4.6 5.5 0.4 6.5 4.2 68 5 65 305 28.1 0.5 29.5 25.2 02/08/2006 16:40:00 4.7 0.6 6.5 3.4 4.2 0.6 5.7 2.6 64 7 66 305 24.5 1.9 27.6 20.4 02/08/2006 16:50:00 4.8 0.5 6.1 3.4 4.3 0.5 5.7 3 63 7 63 305 22.3 0.4 23.4 21.3 02/08/2006 17:00:00 4.3 0.5 5.7 3 3.7 0.4 5.3 2.6 54 7 54 305 21.7 0.9 23.7 20.1 02/08/2006 17:10:00 5.5 1.5 9.9 3.4 5.1 1.6 9.5 3 61 8 62 305 22.3 0.8 24.6 20.4 02/08/2006 17:20:00 8.8 1 11.1 6.1 8.4 1 10.7 6.1 63 6 59 305 22.5 0.8 24.9 20.7 02/08/2006 17:30:00 9.7 1.6 14.5 6.8 9 1.6 13.7 6.1 66 7 71 305 20.1 0.9 22.2 14.8 02/08/2006 17:40:00 11.3 0.9 14.9 8.4 10.9 0.9 14.1 8 71 6 72 305 7.3 11.8 19.6 -8.2 02/08/2006 17:50:00 11.9 1.1 15.3 8.8 11.3 1.2 15.3 8.4 75 6 84 305 -8 0.1 -7.7 -8.2 02/08/2006 18:00:00 11.9 1.2 14.9 8.8 11.4 1.2 14.5 8.4 75 7 80 305 -7.8 0 -7.3 -7.9 02/08/2006 18:10:00 11.6 1.1 14.1 8.8 11.2 1.1 14.9 8 74 7 80 305 -7.6 0.1 -7.1 -7.7 02/08/2006 18:20:00 11.2 1.1 15.3 8 10.8 1.1 14.9 8 74 7 68 305 -7.6 0.1 -7.1 -7.7 02/08/2006 18:30:00 10.9 1.1 13.7 8 10.4 1.2 14.5 7.2 74 8 73 305 -7.4 0.1 -6.9 -7.7 02/08/2006 18:40:00 10.4 1.2 14.9 7.6 10 1.2 13.3 7.2 74 8 80 305 -7.1 0 -6.7 -7.3 02/08/2006 18:50:00 10.1 0.9 12.2 8 9.7 1 13 7.6 72 7 78 305 -6.9 0.1 -6.4 -7.1 02/08/2006 19:00:00 10.6 1.1 15.3 7.6 10.2 1.2 15.6 7.2 73 7 67 305 -6.7 0 -6.2 -6.9 02/08/2006 19:10:00 11 1 13.3 8.4 10.6 1.2 13.7 8 74 7 69 305 -6.5 0 -6.2 -6.7 02/08/2006 19:20:00 11 1.3 14.9 6.8 10.8 1.4 16.1 7.2 74 8 77 305 -6.4 0 -6 -6.7 02/08/2006 19:30:00 10.5 1.4 16.1 5.7 10.2 1.5 14.9 5.7 72 9 58 305 -6.3 0 -6 -6.4 02/08/2006 19:40:00 11.2 1.4 15.3 8 11 1.5 14.9 7.6 72 9 78 305 -6.1 0 -5.8 -6.4 02/08/2006 19:50:00 11.4 1.7 17.2 6.1 11 1.8 16.8 5.3 73 10 84 305 -6 0 -5.8 -6.2 02/08/2006 20:00:00 12 1.6 16.8 7.6 11.7 1.7 16.4 6.1 74 9 62 305 -6 0 -5.8 -6 02/08/2006 20:10:00 11.9 1.6 16.4 9.1 11.4 1.6 16.8 8 76 9 75 305 -5.9 0 -5.6 -6 02/08/2006 20:20:00 11.9 1.4 16.4 8 11.5 1.5 15.3 8 77 8 71 305 -5.9 0 -5.8 -6 02/08/2006 20:30:00 12.2 1.4 16.4 8.4 11.9 1.5 16.1 7.6 78 8 69 305 -6.1 0 -6 -6.2 02/08/2006 20:40:00 12.5 1.6 16.8 8.4 12.2 1.7 16.8 7.6 74 9 60 305 -6.1 0 -5.8 -6.2 02/08/2006 20:50:00 12.7 1.5 17.2 9.1 12.3 1.6 16.4 8.8 76 8 78 305 -6.1 0 -5.8 -6.2 02/08/2006 21:00:00 12 1.3 16.1 8.4 11.8 1.5 15.6 7.2 74 8 67 305 -6.1 0 -5.8 -6.2 02/08/2006 21:10:00 12.3 1.7 17.9 8.4 12 1.9 17.2 6.5 76 11 74 305 -6.1 0 -5.8 -6.2 02/08/2006 21:20:00 12.9 1.7 18.7 8 12.5 1.9 19.9 7.6 76 10 80 305 -6 0 -5.8 -6.2 02/08/2006 21:30:00 13.2 1.9 17.6 8 12.9 2 18.3 8 75 11 60 305 -6 0 -5.8 -6.2 02/08/2006 21:40:00 13.4 1.8 19.1 8 13.1 2.1 18.3 8 74 10 75 305 -6 0 -5.8 -6.2 02/08/2006 21:50:00 13.2 1.8 18.3 9.1 12.9 1.9 17.9 8.8 73 9 74 305 -6.1 0 -5.8 -6.2 02/08/2006 22:00:00 13.4 1.7 18.7 8.4 13 1.7 18.3 8.4 72 9 63 305 -6.1 0 -6 -6.2 02/08/2006 22:10:00 13.1 1.4 17.9 8.8 12.8 1.5 17.2 8 74 9 62 305 -6.2 0 -6 -6.4 02/08/2006 22:20:00 11.9 1.6 16.8 7.6 11.5 1.5 17.2 8 74 8 76 305 -6.3 0 -6.2 -6.4 02/08/2006 22:30:00 12.4 1.3 16.4 9.1 12 1.3 14.9 8.8 75 7 84 305 -6.3 0 -6 -6.4 02/08/2006 22:40:00 12.3 1.2 15.6 8 12 1.2 16.1 8.8 73 8 75 305 -6.1 0 -6 -6.2 02/08/2006 22:50:00 13.3 1.5 17.2 9.5 13 1.6 17.9 9.5 73 8 74 305 -6 0 -5.8 -6.2 02/08/2006 23:00:00 13 1.3 17.2 9.5 12.6 1.4 17.2 8 73 7 62 305 -6.1 0 -5.8 -6.2 02/08/2006 23:10:00 12.8 1.2 16.8 9.5 12.5 1.3 16.8 9.1 74 7 79 305 -6.1 0 -5.8 -6.2 02/08/2006 23:20:00 12.5 1.1 15.3 8.8 12.3 1.2 15.6 8.8 71 5 70 305 -6.1 0 -5.8 -6.2 02/08/2006 23:30:00 12.4 1.3 16.1 9.5 12.2 1.4 16.1 9.1 72 6 67 305 -6 0 -5.8 -6.2 02/08/2006 23:40:00 13.4 1.2 16.4 11.1 13.1 1.2 16.1 9.9 72 6 77 305 -5.9 0 -5.8 -6 02/08/2006 23:50:00 12.9 1.1 16.8 10.3 12.6 1.2 16.8 10.3 72 6 65 305 -5.9 0 -5.6 -6.2 02/09/2006 00:00:00 12.7 1 16.1 9.9 12.6 1.1 16.1 9.9 71 6 74 305 -6 0 -5.8 -6.2 02/09/2006 00:10:00 13.3 1 16.1 10.3 13.1 1.1 15.6 9.1 71 6 78 305 -5.9 0 -5.6 -6 02/09/2006 00:20:00 13.3 1.2 16.1 9.9 13 1.4 16.1 9.9 72 5 71 305 -5.8 0 -5.6 -6 02/09/2006 00:30:00 13.9 1.2 17.6 10.3 13.6 1.4 17.2 9.5 74 6 76 305 -5.8 0 -5.6 -6 02/09/2006 00:40:00 14.3 1.2 17.9 10.7 14 1.4 17.6 9.1 73 6 76 305 -5.7 0 -5.6 -5.8 02/09/2006 00:50:00 14.3 1.3 17.9 11.1 14 1.4 18.3 10.3 73 5 73 305 -5.7 0 -5.6 -5.8 02/09/2006 01:00:00 14.2 1.3 18.3 11.5 13.8 1.5 17.9 10.3 74 6 71 305 -5.6 0 -5.3 -5.8 02/09/2006 01:10:00 14.1 1.5 18.3 9.5 13.6 1.5 17.9 9.5 73 6 77 305 -5.5 0 -5.1 -5.8 02/09/2006 01:20:00 14.6 1.4 19.1 11.5 14.2 1.5 19.9 11.1 75 6 67 305 -5.3 0 -5.1 -5.6 02/09/2006 01:30:00 15.2 1.7 20.2 10.7 14.7 1.9 20.6 10.7 78 7 68 305 -5.2 0 -5.1 -5.6 02/09/2006 01:40:00 14.5 1.7 19.5 10.7 14 1.9 19.1 9.9 80 8 89 305 -5.2 0 -5.1 -5.6 02/09/2006 01:50:00 14.5 1.7 19.9 9.9 13.9 1.7 18.3 9.5 79 7 73 305 -5.3 0 -5.1 -5.6 02/09/2006 02:00:00 14.1 1.4 18.7 10.7 13.7 1.5 19.1 9.9 77 7 76 305 -5.3 0 -4.9 -5.6 02/09/2006 02:10:00 14 1.6 18.3 9.5 13.5 1.7 17.9 8.8 78 7 89 305 -5.2 0 -5.1 -5.3 02/09/2006 02:20:00 13.4 1.3 17.6 9.5 12.9 1.3 17.6 9.1 78 6 75 305 -5.2 0 -5.1 -5.3 02/09/2006 02:30:00 14 1.5 19.5 10.3 13.5 1.5 18.3 9.1 76 8 74 305 -5.1 0 -4.9 -5.3 02/09/2006 02:40:00 13.8 1.3 17.2 9.9 13.3 1.5 17.2 9.1 77 7 82 305 -5.1 0 -5.1 -5.3 02/09/2006 02:50:00 14.1 1.2 17.9 11.1 13.7 1.3 17.9 9.9 76 7 77 305 -5.1 0 -4.9 -5.3 02/09/2006 03:00:00 14.1 1.4 17.9 9.9 13.6 1.6 17.6 8 77 7 81 305 -5.2 0 -4.9 -5.3 02/09/2006 03:10:00 13.5 1.5 17.2 8.8 13.1 1.7 17.6 7.6 78 8 74 305 -5.2 0 -4.9 -5.3 02/09/2006 03:20:00 13 1.3 16.1 9.1 12.5 1.3 15.6 8.8 77 7 82 305 -5.2 0 -5.1 -5.3 02/09/2006 03:30:00 13.5 1.5 18.7 8.8 13 1.5 16.4 8.8 78 7 78 305 -5.2 0 -5.1 -5.3 02/09/2006 03:40:00 14 1.5 17.6 9.9 13.5 1.5 17.9 10.3 80 7 80 305 -5.1 0 -5.1 -5.3 02/09/2006 03:50:00 13.1 1.3 17.6 9.9 12.6 1.4 16.4 9.1 78 6 82 305 -5.1 0 -4.9 -5.3 02/09/2006 04:00:00 12.5 1.3 16.4 9.5 12.2 1.5 16.1 8.8 77 7 77 305 -5 0 -4.9 -5.1 02/09/2006 04:10:00 11.4 0.9 14.5 9.5 11 1 13.3 8.4 76 6 85 305 -5 0 -4.7 -5.1 02/09/2006 04:20:00 11.4 1.1 14.9 8.8 11.1 1.2 15.3 8.4 75 7 79 305 -5 0 -4.7 -5.1 02/09/2006 04:30:00 10.9 1 13.3 8.4 10.5 1 13.7 7.6 77 6 74 305 -5 0 -4.7 -5.1 02/09/2006 04:40:00 10.4 1 13 7.6 10.1 1.1 13 6.8 78 6 75 305 -5 0 -4.7 -5.1 02/09/2006 04:50:00 10.1 1.1 13.3 7.6 9.8 1.2 13 6.8 78 7 80 305 -4.9 0 -4.7 -5.1 02/09/2006 05:00:00 9.8 1.1 13 7.2 9.4 1.2 12.6 6.5 77 8 75 305 -4.9 0 -4.7 -4.9 02/09/2006 05:10:00 9.9 1.3 15.3 4.9 9.7 1.3 14.5 5.3 78 7 73 305 -4.9 0 -4.7 -4.9 02/09/2006 05:20:00 9.6 2 16.4 4.2 9.3 1.8 15.6 5.7 78 12 72 305 -4.8 0 -4.7 -4.9 02/09/2006 05:30:00 8.4 1.9 13.3 3.8 8.2 2.1 13 2.6 77 16 51 305 -4.8 0 -4.7 -4.9 02/09/2006 05:40:00 7.4 2 12.6 3 7 2 13.3 2.6 83 18 62 305 -4.7 0 -4.5 -4.7 02/09/2006 05:50:00 6.3 1.6 11.1 2.3 5.9 1.5 11.5 2.6 83 20 80 305 -4.5 0 -4.2 -4.7 02/09/2006 06:00:00 5.8 1.5 9.5 2.3 5.4 1.7 9.5 0.7 84 23 78 305 -4.3 0 -4 -4.5 02/09/2006 06:10:00 5.8 1.4 11.1 2.3 5.3 1.5 9.1 1.1 97 22 124 305 -4.2 0 -3.8 -4.5 02/09/2006 06:20:00 6.2 1.7 13 2.6 5.6 1.7 12.2 2.3 115 22 106 305 -3.8 0.1 -3.6 -4 02/09/2006 06:30:00 7.9 1.8 13.7 3.4 7.5 1.8 13.3 2.6 119 17 105 305 -3.3 0.2 -3.1 -3.8 02/09/2006 06:40:00 7.3 1.6 12.6 2.6 7.1 1.4 10.3 3.4 123 15 112 305 -3 0 -2.7 -3.3 02/09/2006 06:50:00 7.2 1.7 11.5 3 6.7 1.8 11.8 3 127 18 142 305 -2.8 0 -2.7 -3.1 02/09/2006 07:00:00 7.2 1.5 11.1 3.8 6.8 1.5 10.7 3.4 131 15 151 305 -2.7 0 -2.4 -2.7 02/09/2006 07:10:00 10.5 1.6 14.1 6.1 10 1.7 14.1 5.3 134 10 134 305 -2.5 0 -2.2 -2.7 02/09/2006 07:20:00 11.1 1.5 15.3 6.8 10.8 1.5 15.3 6.5 138 8 144 305 -2.4 0 -2.2 -2.4 02/09/2006 07:30:00 11.4 1.3 14.9 7.6 11.1 1.4 14.9 7.6 138 8 131 305 -2.4 0 -2.2 -2.4 02/09/2006 07:40:00 11.2 1.7 16.4 6.1 10.9 1.4 16.4 6.8 146 11 141 305 -2.3 0 -2.2 -2.7 02/09/2006 07:50:00 11.8 2.2 17.2 5.3 11.3 2 17.9 6.8 148 9 152 305 -2.3 0 -2 -2.4 02/09/2006 08:00:00 9.3 1.2 12.6 5.7 9 1.2 12.6 6.1 143 11 136 305 -2.4 0 -1.8 -2.7 02/09/2006 08:10:00 9.3 1.4 13 5.7 8.9 1.5 13.7 4.6 141 12 147 305 -2.3 0 -1.8 -2.4 02/09/2006 08:20:00 9 1.5 13.3 6.1 8.7 1.5 13.3 5.3 140 10 150 305 -2.2 0 -1.8 -2.4 02/09/2006 08:30:00 9.5 1.2 12.6 5.7 9.1 1.2 12.6 5.7 138 9 140 305 -2.2 0 -1.8 -2.4 02/09/2006 08:40:00 9.3 1.3 14.1 6.1 8.8 1.2 13.7 5.7 137 8 128 305 -2.3 0 -2 -2.4 02/09/2006 08:50:00 8.4 1.5 12.2 4.9 8.1 1.5 11.5 4.6 135 9 139 305 -2.2 0 -1.8 -2.4 02/09/2006 09:00:00 6.8 1.2 10.7 3.4 6.4 1.3 9.9 3.4 136 13 136 305 -2.2 0 -2.2 -2.4 02/09/2006 09:10:00 6 1.2 9.9 3 5.7 1.2 8.8 2.6 132 15 147 305 -2.2 0 -1.8 -2.4 02/09/2006 09:20:00 6.3 1.6 9.9 2.6 5.8 1.6 9.5 2.3 129 16 144 305 -2.4 0 -2.2 -2.4 02/09/2006 09:30:00 6.3 1.2 9.1 3.4 5.9 1.2 9.1 3 127 16 125 305 -2.4 0 -2 -2.4 02/09/2006 09:40:00 6.6 1.5 12.2 3.8 6.2 1.6 12.2 3 134 14 148 305 -2.3 0 -2.2 -2.4 02/09/2006 09:50:00 6.2 1.7 9.9 2.3 5.9 1.7 9.9 2.3 131 15 133 305 -2.2 0 -2 -2.2 02/09/2006 10:00:00 7.6 1.3 11.8 4.2 7.6 1.3 12.2 4.6 132 13 109 305 -2.1 0 -1.8 -2.2 02/09/2006 10:10:00 9 1.5 13 5.3 8.8 1.5 14.1 4.9 131 12 145 305 -2.2 0 -1.8 -2.4 02/09/2006 10:20:00 8.9 1.5 13 4.9 8.6 1.5 13.3 4.9 126 14 101 305 -2.3 0 -2 -2.4 02/09/2006 10:30:00 8.6 1.7 13.3 4.6 8.5 1.6 12.6 4.6 131 14 129 305 -2.5 0 -2.4 -2.7 02/09/2006 10:40:00 8.9 1.4 12.2 5.3 8.5 1.5 12.2 4.6 133 12 137 305 -2.7 0 -2.4 -2.7 02/09/2006 10:50:00 10.2 1.7 15.3 6.1 9.8 1.7 14.1 5.7 133 12 140 305 -2.8 0 -2.4 -2.9 02/09/2006 11:00:00 10 1.5 14.9 6.1 9.6 1.4 13 6.1 135 9 147 305 -2.8 0 -2.2 -3.1 02/09/2006 11:10:00 10 1.5 14.1 6.1 9.5 1.6 15.3 5.3 132 13 145 305 -2.9 0 -2.7 -3.1 02/09/2006 11:20:00 8.9 1.8 13.3 3.8 8.5 1.8 13 4.2 127 13 111 305 -3 0 -2.9 -3.1 02/09/2006 11:30:00 9.1 1.5 13.7 5.7 8.6 1.4 12.6 4.9 130 13 139 305 -3.1 0 -2.9 -3.1 02/09/2006 11:40:00 9.4 1.4 12.6 5.7 9.1 1.4 13 4.9 133 8 137 305 -3.1 0 -2.9 -3.1 02/09/2006 11:50:00 9.5 1.1 11.8 6.5 9.1 1.1 11.5 5.7 135 8 146 305 -2.9 0 -2.7 -3.1 02/09/2006 12:00:00 9.5 1.5 13.7 6.1 9.2 1.5 13.3 4.2 134 9 143 305 -2.8 0 -2.7 -3.1 02/09/2006 12:10:00 9.4 1.3 12.2 4.2 8.9 1.3 12.2 5.3 134 9 121 305 -2.8 0 -2.7 -3.1 02/09/2006 12:20:00 8.7 1.3 11.8 4.9 8.4 1.2 11.5 5.3 141 10 130 305 -2.8 0 -2.7 -3.1 02/09/2006 12:30:00 8.7 1.2 11.5 5.7 8.3 1.2 11.5 4.9 139 9 136 305 -2.8 0 -2.7 -2.9 02/09/2006 12:40:00 7.8 1.2 11.5 4.6 7.5 1.2 10.7 4.6 145 12 156 305 -2.8 0 -2.2 -2.9 02/09/2006 12:50:00 8.2 1.1 11.1 5.3 7.9 1.1 10.7 5.3 143 10 147 305 -2.8 0 -2.7 -3.1 02/09/2006 13:00:00 8 1 11.5 5.7 7.6 0.9 9.9 5.7 143 9 163 305 -2.9 0 -2.7 -3.1 02/09/2006 13:10:00 8.1 1.3 11.1 5.3 7.7 1.3 10.7 4.2 128 13 127 305 -3 0 -2.7 -3.1 02/09/2006 13:20:00 6.6 1.5 11.5 3.4 6 1.3 9.9 2.6 108 17 85 305 -3.1 0.1 -2.7 -3.3 02/09/2006 13:30:00 7.5 1.2 10.3 3.8 6.9 1.2 10.3 4.2 114 10 107 305 -3.2 0 -3.1 -3.3 02/09/2006 13:40:00 7 1.5 9.9 3.4 6.4 1.5 9.9 2.6 112 15 141 305 -3.3 0 -3.1 -3.3 02/09/2006 13:50:00 7 1.5 11.1 3 6.5 1.5 11.8 3 112 15 95 305 -3.3 0 -2.9 -3.3 02/09/2006 14:00:00 6.2 1.3 9.1 2.6 5.7 1.4 9.9 1.5 96 20 46 305 -3.4 0 -2.9 -3.6 02/09/2006 14:10:00 6.5 1.9 12.6 2.6 6 2 11.5 1.9 104 17 102 305 -3.5 0 -3.1 -3.6 02/09/2006 14:20:00 7.2 1.5 11.1 3.8 6.6 1.5 10.7 3 111 15 139 305 -3.3 0 -2.9 -3.6 02/09/2006 14:30:00 8.4 1.7 13 4.2 7.8 1.7 11.5 3.8 105 14 112 305 -3.3 0 -2.9 -3.6 02/09/2006 14:40:00 7.7 1.7 12.6 3 7.2 1.7 12.2 3 111 14 110 305 -3.2 0 -2.9 -3.3 02/09/2006 14:50:00 7.1 1.5 11.8 3.8 6.5 1.5 10.7 3 113 15 107 305 -3 0 -2.7 -3.1 02/09/2006 15:00:00 6.7 1.5 10.7 3 6.1 1.6 11.1 2.6 101 17 130 305 -2.8 0 -2.7 -3.1 02/09/2006 15:10:00 6.9 1.1 9.9 3.8 6.4 1.2 9.1 3 99 15 109 305 -2.7 0 -2.4 -2.7 02/09/2006 15:20:00 5.6 1.1 8.8 2.6 5.2 1.1 8.8 2.6 99 15 90 305 -2.6 0 -2.2 -2.7 02/09/2006 15:30:00 6 1.2 8.8 2.3 5.6 1.2 9.1 1.5 95 18 88 305 -2.3 0 -2.2 -2.4 02/09/2006 15:40:00 7.2 1 8.8 4.2 6.8 0.9 8.4 3.8 82 8 88 305 -2.9 0.3 -2.4 -3.3 02/09/2006 15:50:00 8.1 0.8 10.3 6.1 7.5 0.7 9.1 5.7 85 5 85 305 -3.3 0 -3.1 -3.6 02/09/2006 16:00:00 8.9 1 11.1 5.7 8.2 0.9 10.3 4.9 89 6 88 305 -3.1 0.1 -2.7 -3.6 02/09/2006 16:10:00 8.6 1.1 11.5 5.3 8 1.1 11.1 5.3 85 8 90 305 -2.8 0 -2.7 -3.1 02/09/2006 16:20:00 8.2 0.8 10.7 6.5 7.7 0.8 10.3 5.7 83 5 75 305 -2.9 0 -2.7 -3.1 02/09/2006 16:30:00 8.4 0.7 10.3 6.5 7.9 0.8 10.3 6.1 81 6 91 305 -2.8 0 -2.7 -2.9 02/09/2006 16:40:00 7.7 0.5 9.1 6.1 7.3 0.5 8.4 5.7 78 5 77 305 -2.8 0 -2.7 -2.9 02/09/2006 16:50:00 8.1 0.7 9.9 6.1 7.8 0.7 9.9 5.7 76 5 75 305 -2.8 0 -2.4 -2.7 02/09/2006 17:00:00 8.8 0.8 11.1 6.8 8.5 0.9 10.7 5.7 80 6 75 305 -2.8 0 -2.2 -2.9 02/09/2006 17:10:00 8.4 0.7 10.7 6.8 8 0.7 10.7 6.1 79 5 74 305 -2.8 0 -2.4 -2.9 02/09/2006 17:20:00 8.4 0.6 10.7 6.1 8.1 0.7 10.3 6.1 78 5 80 305 -2.8 0 -2.4 -3.1 02/09/2006 17:30:00 8.3 0.7 10.3 6.1 7.9 0.8 9.9 5.3 79 6 93 305 -2.9 0 -2.4 -3.1 02/09/2006 17:40:00 8.4 0.8 10.7 6.1 8 0.8 10.7 5.7 79 6 81 305 -3 0 -2.7 -3.1 02/09/2006 17:50:00 8.4 1 12.2 5.7 8.1 1.2 11.1 4.9 79 10 63 305 -3 0 -2.7 -3.1 02/09/2006 18:00:00 8.2 1.3 10.7 4.6 7.7 1.4 11.5 4.2 81 10 93 305 -3.1 0 -2.7 -3.1 02/09/2006 18:10:00 8.8 0.9 11.5 6.8 8.3 1 11.8 5.7 81 6 76 305 -3.2 0 -2.7 -3.3 02/09/2006 18:20:00 9.6 0.9 12.2 7.2 9 1 11.8 6.8 83 6 79 305 -3.2 0 -3.1 -3.3 02/09/2006 18:30:00 9.5 1 12.2 6.5 9.1 1.1 11.8 4.9 81 7 71 305 -3.3 0 -2.7 -3.3 02/09/2006 18:40:00 8.7 1 13 6.5 8.3 1.1 13 5.7 79 9 89 305 -3.3 0 -2.9 -3.3 02/09/2006 18:50:00 8.5 0.7 10.7 6.8 8.2 0.8 10.3 6.1 80 6 76 305 -3.3 0 -2.9 -3.3 02/09/2006 19:00:00 8.2 0.8 10.7 5.7 7.7 0.9 11.1 5.7 78 6 71 305 -3.3 0 -3.3 -3.6 02/09/2006 19:10:00 8.5 0.9 12.2 5.7 8.1 1 11.5 5.7 80 7 82 305 -3.4 0 -3.3 -3.6 02/09/2006 19:20:00 8.5 0.7 10.7 6.8 8.1 0.7 9.9 6.5 77 6 77 305 -3.5 0 -3.3 -3.8 02/09/2006 19:30:00 8.6 0.7 10.7 6.8 8.3 0.8 10.3 6.1 74 6 71 305 -3.6 0 -3.3 -3.8 02/09/2006 19:40:00 7.4 0.8 9.5 5.3 7.1 0.8 9.1 4.9 69 7 82 305 -3.8 0 -3.6 -4 02/09/2006 19:50:00 6 0.8 8 4.2 5.6 0.8 7.6 3.8 63 8 62 305 -4 0 -3.8 -4.2 02/09/2006 20:00:00 6.4 1 9.1 4.2 5.9 1 8.8 3.8 67 9 52 305 -4.4 0 -3.8 -4.7 02/09/2006 20:10:00 6.2 1 9.9 3.8 5.8 1 9.5 3.4 64 8 68 305 -4.6 0 -4 -4.7 02/09/2006 20:20:00 7.4 1 10.3 4.6 6.9 1 9.9 4.2 69 8 74 305 -4.7 0.1 -4.2 -4.9 02/09/2006 20:30:00 8.6 1 11.1 6.1 8.2 0.9 10.7 6.1 69 6 78 305 -4.7 0 -4 -4.7 02/09/2006 20:40:00 9 0.9 11.8 6.5 8.6 0.9 10.7 6.1 69 6 77 305 -4.8 0.1 -4.2 -4.9 02/09/2006 20:50:00 10.5 1 13 8 10.2 1 13 7.6 71 5 74 305 -4.8 0.1 -4 -4.9 02/09/2006 21:00:00 10.2 0.8 12.2 8 9.7 0.9 12.2 7.6 71 5 72 305 -5 0 -4.7 -5.1 02/09/2006 21:10:00 9.8 0.9 12.6 8 9.4 0.9 12.2 6.8 69 5 77 305 -4.9 0 -4.7 -5.1 02/09/2006 21:20:00 8.1 0.8 10.7 6.1 7.8 1 10.7 5.7 64 6 73 305 -5 0 -4.5 -5.1 02/09/2006 21:30:00 8.9 1 11.8 6.5 8.5 1.1 11.8 6.1 55 7 63 305 -5 0 -4.5 -5.1 02/09/2006 21:40:00 7.8 1.1 10.3 5.7 7.5 1.1 9.9 4.9 55 7 59 305 -4.9 0 -4.5 -5.1 02/09/2006 21:50:00 8.5 1 11.1 6.1 8.1 1 11.1 5.7 59 6 62 305 -4.7 0 -4.2 -4.9 02/09/2006 22:00:00 8.4 1.1 11.8 5.3 7.9 1.1 11.1 4.9 65 9 71 305 -4.7 0 -4.5 -4.9 02/09/2006 22:10:00 7.2 1.3 9.9 4.6 6.7 1.2 9.5 4.2 63 8 73 305 -4.9 0 -4.5 -5.1 02/09/2006 22:20:00 6.3 0.8 8.4 4.2 5.7 0.8 7.6 3.8 62 8 62 305 -5.2 0 -4.7 -5.6 02/09/2006 22:30:00 5.6 0.8 8 3.8 5.2 0.7 7.6 3.4 58 8 72 305 -5.4 0.1 -4.7 -5.6 02/09/2006 22:40:00 6.9 1 9.5 4.2 6.4 1 9.1 4.2 61 7 62 305 -5.4 0 -4.7 -5.6 02/09/2006 22:50:00 6.4 1.1 9.5 3.8 5.9 1 9.1 3.4 60 7 75 305 -5.6 0 -4.9 -5.8 02/09/2006 23:00:00 7 1.1 9.9 4.6 6.6 1.2 10.3 4.2 58 7 66 305 -5.6 0 -5.3 -5.8 02/09/2006 23:10:00 8.2 1 10.7 5.7 7.8 1.1 10.3 5.3 61 6 59 305 -5.8 0 -5.6 -6 02/09/2006 23:20:00 7.4 1 10.3 4.6 7 1.1 9.5 3.8 59 7 54 305 -5.8 0 -5.6 -6 02/09/2006 23:30:00 7.8 1.1 11.1 4.6 7.3 1.2 10.7 3.8 58 6 56 305 -5.7 0 -5.6 -6 02/09/2006 23:40:00 9.1 0.8 11.1 6.8 8.6 0.9 11.1 6.1 58 6 60 305 -5.8 0.1 -5.6 -6.2 02/09/2006 23:50:00 8.4 0.7 9.9 6.8 7.9 0.8 9.9 5.7 57 5 69 305 -6.1 0 -6 -6.2 02/10/2006 00:00:00 6.6 0.7 8.8 4.9 6.1 0.7 8.8 4.6 56 5 72 305 -6.2 0 -6.2 -6.4 02/10/2006 00:10:00 5.7 0.6 7.6 4.6 5.2 0.6 7.6 3.4 52 5 57 305 -6.2 0 -6 -6.4 02/10/2006 00:20:00 5.2 1 7.2 2.6 4.6 1 7.6 2.3 48 8 55 305 -6.3 0 -6.2 -6.7 02/10/2006 00:30:00 6.2 0.8 8.4 4.2 5.7 0.8 8 3.8 39 7 39 305 -6.2 0 -6 -6.4 02/10/2006 00:40:00 7.1 1 10.3 4.9 6.7 1 9.1 4.9 40 7 54 305 -6.2 0 -6 -6.4 02/10/2006 00:50:00 7.7 1 10.7 5.3 7.1 1 9.9 4.6 49 7 57 305 -6.2 0 -6 -6.4 02/10/2006 01:00:00 7.8 0.8 10.3 5.3 7.4 0.8 9.1 5.3 51 7 54 305 -6.1 0 -6 -6.2 02/10/2006 01:10:00 8.2 1.1 11.5 5.7 7.7 1.1 11.1 5.7 50 7 45 305 -6.2 0 -5.8 -6.4 02/10/2006 01:20:00 10.1 1.7 14.5 6.8 9.6 1.6 13.7 6.5 44 8 46 305 -6.1 0 -5.8 -6.2 02/10/2006 01:30:00 11.8 1.3 15.6 8.8 11.2 1.3 15.3 8.4 43 7 37 305 -6.1 0 -6 -6.2 02/10/2006 01:40:00 9.6 1.1 12.6 6.5 9.1 1.2 12.6 6.1 53 8 44 305 -6.3 0.1 -6 -6.7 02/10/2006 01:50:00 9.5 1.2 12.2 6.1 9 1.2 12.2 6.1 57 7 52 305 -6.4 0 -6.2 -6.7 02/10/2006 02:00:00 9.7 1.5 14.1 6.8 9.3 1.5 14.5 6.1 58 7 54 305 -6.2 0 -6 -6.4 02/10/2006 02:10:00 11.5 1.1 14.1 8.4 11.1 1.2 13.7 8 57 7 62 305 -6.2 0 -6 -6.2 02/10/2006 02:20:00 12.5 1.2 15.6 9.1 12 1.3 15.6 9.1 52 6 52 305 -6.1 0 -6 -6.2 02/10/2006 02:30:00 12.5 1.2 15.6 9.5 12 1.2 15.3 9.1 51 6 46 305 -6.1 0 -6 -6.2 02/10/2006 02:40:00 11.8 1.2 14.5 8.4 11.3 1.2 14.5 8 56 6 64 305 -6.1 0 -6 -6.2 02/10/2006 02:50:00 11.5 1.1 14.9 8 11 1.2 14.1 8 56 7 52 305 -6.1 0 -6 -6.2 02/10/2006 03:00:00 10.9 1.1 14.1 8 10.4 1.1 13.7 8 54 6 57 305 -6.1 0 -5.8 -6.2 02/10/2006 03:10:00 10 0.8 11.8 7.6 9.6 0.9 12.6 7.2 51 5 58 305 -6.3 0.1 -6 -6.7 02/10/2006 03:20:00 9.8 0.9 11.8 7.2 9.4 0.9 12.2 6.8 52 6 62 305 -6.2 0 -6 -6.4 02/10/2006 03:30:00 9.3 1 11.8 6.5 9 1.1 11.8 6.8 52 6 52 305 -6.2 0 -6 -6.4 02/10/2006 03:40:00 9.5 1 12.2 7.2 9.1 1 12.2 6.5 54 6 59 305 -6.4 0 -6.2 -6.7 02/10/2006 03:50:00 9.8 1 13 7.2 9.4 1.1 12.6 6.1 57 6 58 305 -6.4 0 -6.2 -6.7 02/10/2006 04:00:00 10.1 1 13 7.6 9.7 1 12.2 7.2 57 6 55 305 -6.2 0 -6 -6.4 02/10/2006 04:10:00 9.8 1.1 13 7.2 9.5 1.2 12.6 6.5 60 5 59 305 -6.1 0 -5.8 -6.2 02/10/2006 04:20:00 9.7 1 11.8 6.8 9.3 1 11.5 6.8 57 5 56 305 -6.1 0 -5.8 -6.2 02/10/2006 04:30:00 9.1 1 11.5 6.8 8.8 0.9 11.1 6.8 57 6 46 305 -6.1 0 -5.8 -6.2 02/10/2006 04:40:00 10 1 14.1 7.2 9.7 1 12.6 7.2 62 6 77 305 -5.9 0 -5.8 -6.2 02/10/2006 04:50:00 11.9 1.6 16.1 8 11.5 1.6 15.6 8 66 7 60 305 -5.6 0 -5.3 -5.8 02/10/2006 05:00:00 13.1 1.3 16.8 9.5 12.8 1.4 16.8 9.5 67 5 67 305 -5.8 0.1 -5.6 -6 02/10/2006 05:10:00 10.7 1.3 14.9 7.6 10.5 1.3 14.1 7.2 67 6 76 305 -6 0 -5.8 -6 02/10/2006 05:20:00 10.2 1 13.3 8 9.8 1 13 7.6 62 7 65 305 -6 0 -5.8 -6.2 02/10/2006 05:30:00 10 1.1 12.6 7.6 9.7 1.1 12.6 6.8 63 6 72 305 -6 0 -5.8 -6 02/10/2006 05:40:00 10.3 1.1 13.3 8 9.9 1.2 12.6 7.2 67 6 87 305 -6 0 -5.8 -6 02/10/2006 05:50:00 10.4 1.2 14.1 7.2 10.1 1.3 13.3 7.6 65 6 71 305 -6 0 -5.8 -6 02/10/2006 06:00:00 10.8 0.9 13.3 8.4 10.5 1 13.3 8 68 6 71 305 -5.9 0 -5.8 -6 02/10/2006 06:10:00 11.7 1.2 14.5 9.1 11.3 1.2 14.1 8.4 69 6 80 305 -5.8 0 -5.8 -6 02/10/2006 06:20:00 11 1.5 16.1 8 10.7 1.5 16.1 8 69 6 63 305 -5.8 0 -5.6 -6 02/10/2006 06:30:00 11.9 1.2 14.9 9.1 11.6 1.3 14.9 8 70 6 74 305 -5.7 0 -5.6 -5.8 02/10/2006 06:40:00 11.6 1.2 14.9 8 11.4 1.3 14.5 7.6 70 6 80 305 -5.7 0 -5.6 -5.8 02/10/2006 06:50:00 11.8 1.3 14.9 8.8 11.5 1.5 14.5 8 70 6 77 305 -5.6 0 -5.6 -5.8 02/10/2006 07:00:00 12.1 1.2 14.9 9.1 11.8 1.2 14.9 8.8 70 5 73 305 -5.6 0 -5.1 -5.8 02/10/2006 07:10:00 10.6 1.2 13.7 7.6 10.3 1.3 13.7 7.2 68 6 68 305 -5.6 0 -5.6 -5.8 02/10/2006 07:20:00 10.3 1.1 13.3 7.2 9.9 1.1 13 7.2 67 7 74 305 -5.5 0 -5.6 -5.8 02/10/2006 07:30:00 10 1.2 13.7 7.2 9.7 1.2 13.3 6.5 65 7 65 305 -5.5 0 -5.3 -5.8 02/10/2006 07:40:00 10 1 12.6 7.2 9.6 1.1 12.6 6.8 66 7 56 305 -5.5 0 -5.1 -5.6 02/10/2006 07:50:00 9.5 1 12.2 6.8 9.2 1 13 6.8 66 7 65 305 -5.3 0 -5.1 -5.6 02/10/2006 08:00:00 9.8 1.2 13.7 6.8 9.3 1.1 13.3 6.8 67 8 68 305 -5.2 0 -4.9 -5.3 02/10/2006 08:10:00 9.8 1 13 6.8 9.5 1 13.3 7.2 66 7 65 305 -5.1 0 -4.9 -5.3 02/10/2006 08:20:00 9.8 1.1 12.6 6.8 9.4 1.1 12.2 6.1 66 8 67 305 -5 0 -4.7 -5.1 02/10/2006 08:30:00 10.4 1.2 13.7 6.8 10.1 1.2 13.3 6.8 68 7 69 305 -4.9 0 -4.7 -5.1 02/10/2006 08:40:00 10.7 1.2 14.1 8 10.2 1.2 14.1 7.2 69 7 70 305 -4.7 0 -4.7 -4.9 02/10/2006 08:50:00 11.2 1.2 14.9 8.8 10.8 1.2 14.9 8 70 6 64 305 -4.6 0 -4.2 -4.7 02/10/2006 09:00:00 11.6 1 14.5 9.1 11.3 1.1 13.7 8.4 71 6 73 305 -4.4 0 -4.2 -4.7 02/10/2006 09:10:00 12 1.1 14.5 8.8 11.6 1.1 14.5 8.8 70 6 81 305 -4.2 0 -4 -4.5 02/10/2006 09:20:00 12.4 1.2 16.1 8.4 12.1 1.3 15.3 8.4 70 6 73 305 -4.1 0 -3.8 -4.2 02/10/2006 09:30:00 12.3 1.2 16.1 8.4 11.9 1.3 15.6 8.8 71 7 58 305 -3.9 0 -3.8 -4 02/10/2006 09:40:00 12.6 1.2 16.4 8.8 12.3 1.2 16.1 7.2 73 7 71 305 -3.9 0 -3.6 -4 02/10/2006 09:50:00 12.6 1.1 16.1 9.5 12.2 1.2 14.9 9.1 72 6 77 305 -3.7 0 -3.6 -3.8 02/10/2006 10:00:00 12.8 1.1 15.3 9.1 12.4 1.1 16.1 9.5 73 5 73 305 -3.5 0 -3.3 -3.8 02/10/2006 10:10:00 12.6 1 15.3 9.5 12.3 1 15.3 9.1 73 6 85 305 -3.3 0 -3.1 -3.6 02/10/2006 10:20:00 12.7 1 15.3 9.5 12.5 1.2 16.1 9.1 73 6 70 305 -3.2 0 -3.1 -3.3 02/10/2006 10:30:00 12.8 1.1 16.1 9.1 12.5 1.3 15.6 9.1 73 6 91 305 -3.1 0 -2.9 -3.3 02/10/2006 10:40:00 12.4 1.2 16.8 9.5 12.1 1.2 16.1 8.8 75 6 77 305 -2.9 0 -2.7 -3.1 02/10/2006 10:50:00 11.8 1 14.9 9.5 11.5 1.1 14.5 9.1 76 6 84 305 -2.8 0 -2.7 -3.1 02/10/2006 11:00:00 11.8 1 14.5 9.5 11.5 1.1 14.5 8.8 76 7 76 305 -2.8 0 -2.2 -2.9 02/10/2006 11:10:00 11.5 1.1 14.9 9.1 11 1.2 14.9 8.4 78 7 73 305 -2.7 0 -2 -2.7 02/10/2006 11:20:00 11.5 1.4 15.6 7.2 11.1 1.4 14.9 6.8 75 7 77 305 -2.5 0 -2 -2.7 02/10/2006 11:30:00 11.3 1 14.1 8.8 10.9 1.1 13.7 8.4 78 7 87 305 -2.3 0 -1.8 -2.4 02/10/2006 11:40:00 11.2 1.1 14.1 8.8 10.9 1.3 13.7 7.6 78 7 81 305 -2.2 0 -1.8 -2.4 02/10/2006 11:50:00 11.2 1.1 14.1 8 10.9 1.1 13.7 7.6 78 6 84 305 -2.2 0 -1.8 -2.2 02/10/2006 12:00:00 11.3 1.1 14.5 8.4 11 1.2 13.7 8 80 7 77 305 -2.1 0.1 -1.8 -2.2 02/10/2006 12:10:00 11.1 1.2 13.7 8.4 10.8 1.2 13.7 7.6 79 7 94 305 -2 0 -1.8 -2.2 02/10/2006 12:20:00 11.1 1.1 14.5 8.4 10.8 1.1 14.9 8.4 79 6 85 305 -2 0 -1.5 -2.2 02/10/2006 12:30:00 11.1 0.9 14.5 7.6 10.7 1 14.1 7.6 78 6 82 305 -2 0 -1.5 -2 02/10/2006 12:40:00 10.9 1.1 14.5 8.4 10.6 1.2 14.1 7.6 77 7 77 305 -1.9 0 -1.5 -2 02/10/2006 12:50:00 10.9 1 13.7 8 10.6 1.1 13.3 8 78 6 82 305 -1.9 0 -1.5 -2 02/10/2006 13:00:00 10.5 1 13 7.6 10.1 1 12.6 7.2 78 8 73 305 -1.9 0 -1.3 -2 02/10/2006 13:10:00 11 1 13.7 8.8 10.7 1 13.7 8 77 6 68 305 -2.1 0.1 -1.5 -2.2 02/10/2006 13:20:00 11 1 14.9 7.6 10.6 1.1 13.7 8 77 6 82 305 -2.1 0 -1.8 -2.2 02/10/2006 13:30:00 11.3 0.9 13.7 9.1 11 1 13.7 8.8 76 5 80 305 -2.2 0 -2 -2.2 02/10/2006 13:40:00 11.5 0.9 14.1 9.1 11.2 1 14.5 8.8 76 5 82 305 -2.2 0 -1.8 -2.2 02/10/2006 13:50:00 11.4 1 13.7 8.4 11.1 1.1 14.9 7.6 76 6 79 305 -2.2 0 -1.8 -2.4 02/10/2006 14:00:00 11.4 1 14.9 8.8 11 1 14.1 8 76 5 74 305 -2.2 0 -1.8 -2.4 02/10/2006 14:10:00 11.6 1 14.1 9.1 11.3 1.1 13.7 8.4 75 5 73 305 -2.3 0 -1.8 -2.4 02/10/2006 14:20:00 11.7 0.8 13.7 9.5 11.4 0.9 14.1 9.1 75 5 68 305 -2.4 0 -2 -2.4 02/10/2006 14:30:00 11.8 0.9 14.5 9.5 11.5 1 14.1 9.1 75 5 79 305 -2.4 0 -2 -2.7 02/10/2006 14:40:00 11.7 1 14.9 9.1 11.3 1.2 14.5 8.4 77 6 67 305 -2.5 0 -2 -2.7 02/10/2006 14:50:00 11.9 1.1 14.5 8.8 11.4 1.1 14.1 8.4 77 7 70 305 -2.5 0 -2.4 -2.7 02/10/2006 15:00:00 12 1.1 15.3 8.4 11.6 1.1 14.9 8.4 80 7 78 305 -2.4 0 -2 -2.7 02/10/2006 15:10:00 11.1 1 14.1 8.4 10.7 1 13.3 8 80 7 80 305 -2.4 0 -2 -2.7 02/10/2006 15:20:00 11.1 1 14.5 9.1 10.8 1 13.3 8.4 78 7 65 305 -2.5 0 -2 -2.7 02/10/2006 15:30:00 11.1 1 14.5 8.8 10.7 1.2 15.3 8 79 8 56 305 -2.4 0 -2 -2.4 02/10/2006 15:40:00 10.8 1 13.7 8 10.4 1 13 8 79 7 70 305 -2.3 0 -1.8 -2.4 02/10/2006 15:50:00 11.1 1 13.3 8 10.6 1.2 13.3 6.8 80 7 86 305 -2.2 0 -1.8 -2.4 02/10/2006 16:00:00 10.9 1.1 13.7 8 10.5 1.1 13.7 7.6 80 7 80 305 -2.2 0 -1.8 -2.4 02/10/2006 16:10:00 11 1.1 14.1 8 10.6 1.1 14.1 7.2 78 6 77 305 -2.3 0 -1.8 -2.4 02/10/2006 16:20:00 10.6 1 13 7.2 10.2 1.1 13 7.2 78 7 81 305 -2.3 0 -1.8 -2.4 02/10/2006 16:30:00 10.3 1 12.6 7.6 9.9 1.1 12.6 7.2 78 6 77 305 -2.3 0 -1.8 -2.4 02/10/2006 16:40:00 10.1 1.1 13 7.2 9.7 1.2 13.3 6.8 79 7 74 305 -2.4 0 -2 -2.4 02/10/2006 16:50:00 10 1 12.6 7.6 9.5 1.1 12.6 6.8 78 7 80 305 -2.3 0 -1.8 -2.4 02/10/2006 17:00:00 10.2 1 13.7 7.6 9.9 1.1 13.3 7.2 79 7 74 305 -2.3 0 -2 -2.4 02/10/2006 17:10:00 10.3 1 13.7 7.6 9.9 1 13.7 6.5 79 6 82 305 -2.3 0 -2 -2.4 02/10/2006 17:20:00 10.6 1 13 7.6 10.3 1 13.3 7.2 79 6 86 305 -2.3 0 -2 -2.4 02/10/2006 17:30:00 10.2 1.2 13 7.2 9.8 1.2 13.3 7.2 78 7 89 305 -2.3 0 -2 -2.4 02/10/2006 17:40:00 9.8 1 13 7.2 9.4 1.1 12.6 7.2 78 7 73 305 -2.3 0 -1.8 -2.4 02/10/2006 17:50:00 9.8 1.1 13 6.8 9.3 1.1 12.2 6.5 79 7 80 305 -2.3 0 -2 -2.4 02/10/2006 18:00:00 9.8 0.9 12.2 7.2 9.3 1.1 12.2 6.5 78 7 85 305 -2.3 0 -2 -2.4 02/10/2006 18:10:00 9.7 1 12.2 7.2 9.2 1.1 12.2 6.5 79 7 87 305 -2.4 0 -2.2 -2.4 02/10/2006 18:20:00 9.3 0.9 11.5 6.8 8.9 0.9 11.5 5.7 80 7 83 305 -2.4 0 -2 -2.4 02/10/2006 18:30:00 9.4 1 11.8 6.5 8.9 1 11.1 6.5 80 6 90 305 -2.4 0 -2.4 -2.4 02/10/2006 18:40:00 9 0.8 11.1 6.8 8.5 0.9 10.7 6.1 78 7 87 305 -2.4 0 -2 -2.7 02/10/2006 18:50:00 8.6 0.8 11.1 6.8 8.2 0.9 11.1 6.1 77 6 78 305 -2.4 0 -2 -2.7 02/10/2006 19:00:00 8.6 0.8 10.7 6.5 8.2 0.9 10.7 5.3 75 6 73 305 -2.5 0 -2 -2.7 02/10/2006 19:10:00 8.7 0.7 10.7 6.8 8.4 0.8 10.3 6.8 76 5 78 305 -2.6 0 -2.2 -2.7 02/10/2006 19:20:00 8.8 0.7 10.7 6.8 8.3 0.8 10.7 6.5 75 5 68 305 -2.6 0 -2.2 -2.7 02/10/2006 19:30:00 9.1 0.8 13 7.2 8.6 0.9 11.8 6.1 76 6 74 305 -2.7 0 -2.4 -2.7 02/10/2006 19:40:00 9.5 0.8 12.2 7.6 9 0.9 11.1 6.8 78 5 80 305 -2.7 0 -2.4 -2.7 02/10/2006 19:50:00 9.8 0.8 11.8 7.2 9.4 0.9 12.2 6.8 77 5 72 305 -2.8 0 -2.4 -2.7 02/10/2006 20:00:00 10.2 0.8 12.6 8.4 9.8 0.9 12.6 8 77 5 73 305 -2.8 0 -2.4 -2.9 02/10/2006 20:10:00 10.2 0.7 12.2 8 9.8 0.8 12.2 8 75 5 70 305 -2.8 0 -2.4 -3.1 02/10/2006 20:20:00 10.3 0.8 12.2 8.4 9.9 0.8 12.2 7.6 75 5 72 305 -3 0 -2.7 -3.1 02/10/2006 20:30:00 10.6 0.7 12.6 9.1 10.2 0.8 12.2 8.4 77 5 75 305 -3.1 0 -2.7 -3.3 02/10/2006 20:40:00 10.2 0.9 13.3 8 9.7 0.9 12.6 7.2 79 5 78 305 -3.2 0 -2.7 -3.3 02/10/2006 20:50:00 10.1 0.8 13 8 9.6 0.8 12.2 7.6 78 6 77 305 -3.3 0 -2.7 -3.3 02/10/2006 21:00:00 10.3 0.8 12.2 8.4 9.9 1 12.6 7.6 77 6 75 305 -3.3 0 -2.7 -3.3 02/10/2006 21:10:00 10.3 0.7 12.6 8.4 9.8 0.8 12.2 8 79 5 79 305 -3.3 0 -2.9 -3.3 02/10/2006 21:20:00 10.1 0.9 13 8 9.7 1 13 7.2 78 6 84 305 -3.3 0 -2.7 -3.3 02/10/2006 21:30:00 10.3 0.9 14.1 8.4 9.9 1 13.3 7.6 78 6 81 305 -3.3 0 -2.7 -3.3 02/10/2006 21:40:00 10.4 1 13.3 7.2 9.9 1.1 13.3 6.8 80 5 87 305 -3.3 0 -2.9 -3.3 02/10/2006 21:50:00 10.7 1 13.3 8.4 10.2 1 13.3 7.2 80 7 80 305 -3.3 0 -2.7 -3.3 02/10/2006 22:00:00 10.5 0.9 12.6 8 10.1 1 12.6 7.6 79 7 71 305 -3.2 0 -2.7 -3.3 02/10/2006 22:10:00 10.3 1.1 13.7 7.6 9.9 1.2 13.3 7.2 76 6 65 305 -3.3 0 -2.7 -3.3 02/10/2006 22:20:00 10.3 0.8 12.2 8 10 1 13 7.6 74 5 75 305 -3.3 0 -2.7 -3.3 02/10/2006 22:30:00 10.8 0.7 13 9.1 10.4 0.8 12.6 8 73 5 69 305 -3.2 0 -2.7 -3.3 02/10/2006 22:40:00 10.9 0.8 13.7 8.8 10.5 0.9 12.6 8 75 5 87 305 -3.2 0 -2.7 -3.3 02/10/2006 22:50:00 10.4 0.9 14.1 8.4 9.9 1 14.1 7.6 77 6 72 305 -3.2 0 -3.1 -3.3 02/10/2006 23:00:00 11.1 1 13.7 8.8 10.7 1 13.7 8 77 6 74 305 -3.1 0 -2.7 -3.3 02/10/2006 23:10:00 10.9 0.9 13 8.4 10.5 0.9 13 7.6 76 6 81 305 -2.9 0 -2.4 -3.1 02/10/2006 23:20:00 11 0.9 14.1 8.4 10.6 0.9 13.7 8.4 76 6 67 305 -2.8 0 -2.2 -2.9 02/10/2006 23:30:00 10.8 1 13.7 8.8 10.4 1 13 8 76 6 70 305 -2.7 0 -2.4 -2.7 02/10/2006 23:40:00 10.6 0.9 13.7 8.8 10.2 0.9 13.7 8 77 5 73 305 -2.6 0.1 -2 -2.7 02/10/2006 23:50:00 10.7 0.9 13 8.4 10.4 1 13.3 8 76 6 65 305 -2.6 0 -2.2 -2.7 02/11/2006 00:00:00 10.8 1 13.3 7.6 10.5 1 13.3 7.6 75 6 75 305 -2.4 0 -1.8 -2.7 02/11/2006 00:10:00 11 1 14.1 8.4 10.7 1 14.5 8.8 75 6 84 305 -2.3 0 -1.8 -2.4 02/11/2006 00:20:00 11 1.1 14.1 8.4 10.5 1.2 14.1 8 76 7 71 305 -2.3 0 -1.8 -2.4 02/11/2006 00:30:00 11.2 1.1 14.1 8.4 10.7 1.1 14.9 7.6 75 6 83 305 -2.2 0 -1.8 -2.4 02/11/2006 00:40:00 10.9 0.8 13.3 8.8 10.7 0.9 13 8.4 73 6 73 305 -2.2 0 -1.8 -2.4 02/11/2006 00:50:00 10.6 0.9 13.3 8.8 10.4 1 13.7 8 73 5 78 305 -2.2 0 -1.8 -2.2 02/11/2006 01:00:00 10.5 0.9 13 8.8 10.2 0.9 13 8 74 6 73 305 -2 0 -1.8 -2.2 02/11/2006 01:10:00 10.5 1.2 14.5 6.8 10.1 1.3 13.3 6.8 75 9 77 305 -1.8 0 -1.3 -2 02/11/2006 01:20:00 10.6 1.3 15.3 7.6 10.2 1.3 14.5 7.6 75 9 81 305 -1.6 0.1 -1.1 -1.8 02/11/2006 01:30:00 10.6 1.1 13.7 7.6 10.4 1.1 14.1 6.8 73 7 78 305 -0.8 0.6 0.6 -1.8 02/11/2006 01:40:00 9.4 1.5 13.3 5.7 9.2 1.4 13 6.1 70 10 69 305 1.7 0.5 2.7 0.1 02/11/2006 01:50:00 8.4 2.1 14.1 3 8.2 2.1 13.7 3 66 16 73 305 1.7 0.2 2.7 1.3 02/11/2006 02:00:00 6.9 2.4 12.6 1.5 6.6 2.4 11.8 1.9 84 30 101 305 2.8 0.9 4.7 1 02/11/2006 02:10:00 6.3 1.9 11.8 1.1 5.9 1.8 11.5 0.7 100 26 71 305 2.2 1.6 5.2 -1.1 02/11/2006 02:20:00 6.9 2 15.3 3 6.5 1.8 14.9 2.6 106 23 140 305 -0.8 0 -0.1 -0.8 02/11/2006 02:30:00 6.2 2.4 13 0.7 5.8 2.3 11.8 0.4 103 28 83 305 -0.5 0.5 0.6 -1.1 02/11/2006 02:40:00 5.9 1.7 11.8 1.9 5.4 1.6 10.3 1.5 92 26 109 305 -0.8 0 -0.4 -1.1 02/11/2006 02:50:00 6.5 2.2 13 2.3 6 2.3 13 0.4 102 30 128 305 -0.9 0 -0.4 -1.1 02/11/2006 03:00:00 6.9 2.3 15.3 2.3 6.4 2.2 14.9 1.9 94 24 112 305 -1 0.1 -0.4 -1.1 02/11/2006 03:10:00 5.1 1.7 10.7 1.5 4.8 1.8 11.8 0.4 105 32 122 305 -1.1 0 -0.4 -1.3 02/11/2006 03:20:00 7.2 2.4 14.5 2.6 6.8 2.4 13.3 1.5 111 22 112 305 -1.1 0 -0.6 -1.3 02/11/2006 03:30:00 7.6 2.2 13 1.5 7.3 2 12.6 1.9 114 24 104 305 -1.1 0 -0.6 -1.3 02/11/2006 03:40:00 10 2.8 17.9 3.8 9.6 2.8 17.2 2.6 121 20 137 305 -1.2 0 -0.6 -1.3 02/11/2006 03:50:00 9.9 2.5 16.8 4.6 9.6 2.6 16.4 4.2 121 19 116 305 -1.4 0.1 -0.6 -1.5 02/11/2006 04:00:00 10.5 2.2 17.6 6.1 10 2.1 16.8 5.3 124 15 103 305 -1.5 0.1 -1.1 -1.8 02/11/2006 04:10:00 10.1 2.3 17.9 5.3 9.5 2.3 16.1 3.8 123 16 121 305 -1.6 0 -1.1 -1.8 02/11/2006 04:20:00 10 2.1 16.8 3.8 9.6 2 16.1 4.2 125 17 124 305 -1.7 0 -1.1 -1.8 02/11/2006 04:30:00 11.3 2.2 17.9 4.9 10.9 2.2 18.3 5.3 129 15 127 305 -1.7 0 -1.1 -1.8 02/11/2006 04:40:00 10.7 2.1 17.2 6.1 10.2 2 16.4 5.7 119 17 127 305 -1.7 0 -1.3 -1.8 02/11/2006 04:50:00 11.7 2.1 16.4 6.8 11.3 2.1 16.4 7.2 124 14 127 305 -1.8 0 -1.3 -2 02/11/2006 05:00:00 11.2 2 16.8 6.1 10.7 2.1 16.8 5.3 124 15 122 305 -1.8 0 -1.3 -2 02/11/2006 05:10:00 10.8 2.2 18.3 6.1 10.4 2.1 17.2 6.1 121 15 138 305 -1.8 0 -1.3 -2 02/11/2006 05:20:00 11.1 2.3 16.8 6.5 10.6 2.2 17.2 4.9 123 15 135 305 -1.8 0 -1.3 -2 02/11/2006 05:30:00 11.5 2.1 18.7 7.2 11.1 2.1 17.2 6.5 126 15 127 305 -1.9 0 -1.3 -2 02/11/2006 05:40:00 11.8 2.4 19.9 6.5 11.4 2.4 18.3 6.1 125 13 123 305 -1.9 0 -1.3 -2 02/11/2006 05:50:00 10.7 2.4 17.9 5.3 10.5 2.4 16.1 5.3 121 13 140 305 -1.9 0 -1.3 -2 02/11/2006 06:00:00 10.2 2.3 16.4 5.3 9.8 2.3 15.6 4.9 121 14 97 305 -1.9 0 -1.5 -2 02/11/2006 06:10:00 10 2.3 19.1 4.2 9.4 2.3 19.9 4.2 122 15 120 305 -2 0 -1.5 -2.2 02/11/2006 06:20:00 10.6 1.9 15.6 4.9 10 1.9 14.9 5.3 125 15 139 305 -2 0 -1.5 -2 02/11/2006 06:30:00 11.4 2.3 17.6 5.7 11.1 2.2 16.8 5.7 128 13 118 305 -2 0 -1.5 -2 02/11/2006 06:40:00 11.9 2.3 17.6 7.2 11.4 2.1 16.8 7.2 130 14 99 305 -2 0.1 -1.5 -2.2 02/11/2006 06:50:00 14.1 1.8 19.9 9.5 13.6 1.8 19.1 8.4 132 9 143 305 -2 0 -1.5 -2.2 02/11/2006 07:00:00 14.7 1.7 19.5 10.3 14.1 1.6 18.3 8.8 133 7 122 305 -2.1 0 -2 -2.2 02/11/2006 07:10:00 15.5 1.7 19.1 9.1 14.8 1.7 18.3 9.1 134 6 132 305 -2.1 0 -1.8 -2.2 02/11/2006 07:20:00 16 1.5 19.5 11.5 15.4 1.5 18.3 10.7 134 6 130 305 -2.1 0.1 -1.8 -2.2 02/11/2006 07:30:00 15.7 1.3 21.8 11.5 15.3 1.4 20.2 11.5 134 6 127 305 -2.1 0 -2 -2.2 02/11/2006 07:40:00 15.4 1.3 18.7 11.5 14.9 1.5 18.3 10.7 133 6 136 305 -2.1 0 -1.8 -2.2 02/11/2006 07:50:00 15.3 1.3 18.3 11.1 14.7 1.3 17.9 10.7 133 5 136 305 -2.1 0 -1.8 -2.2 02/11/2006 08:00:00 15.4 1.3 18.7 11.5 14.9 1.3 18.7 11.1 134 5 135 305 -2.1 0.1 -1.8 -2.2 02/11/2006 08:10:00 14.1 1.3 18.7 9.5 13.6 1.5 17.9 8.8 134 6 140 305 -2.2 0 -1.8 -2.2 02/11/2006 08:20:00 13.5 1.3 16.8 9.1 13 1.3 16.4 9.5 133 6 126 305 -2.2 0 -1.8 -2.2 02/11/2006 08:30:00 12.6 1.2 16.1 8.8 12.2 1.2 16.1 8 132 7 138 305 -2.2 0 -1.8 -2.2 02/11/2006 08:40:00 10.8 1.5 14.5 6.5 10.6 1.5 13.7 6.5 131 9 121 305 -2.2 0 -1.8 -2.2 02/11/2006 08:50:00 8.7 1.5 12.6 5.7 8.5 1.5 12.6 4.9 124 13 130 305 -2.2 0 -1.8 -2.2 02/11/2006 09:00:00 7.6 1.1 11.5 4.2 7.2 1 10.7 4.6 114 12 109 305 -2.2 0 -1.8 -2.4 02/11/2006 09:10:00 7.4 1.5 11.5 3.4 6.9 1.5 11.5 3.8 109 12 119 305 -2.2 0 -1.8 -2.4 02/11/2006 09:20:00 6.4 1.3 10.3 3.4 6 1.2 9.1 3 112 14 118 305 -2.2 0 -1.8 -2.4 02/11/2006 09:30:00 5.9 1.3 10.3 3 5.4 1.3 9.5 2.3 112 15 131 305 -2.3 0 -1.8 -2.4 02/11/2006 09:40:00 5.1 1.3 8.8 2.3 4.5 1.3 8.4 1.9 117 18 138 305 -2.3 0 -2.2 -2.4 02/11/2006 09:50:00 5.5 1.3 8.8 3 5.3 1.3 9.5 2.6 124 15 136 305 -2.4 0 -1.8 -2.4 02/11/2006 10:00:00 6.8 1.2 10.3 3.4 6.4 1.2 10.7 2.3 122 13 127 305 -2.4 0 -2 -2.7 02/11/2006 10:10:00 6.3 1.3 9.5 2.6 5.9 1.2 9.9 3 122 13 137 305 -2.4 0 -2 -2.4 02/11/2006 10:20:00 6.9 1.2 11.1 4.6 6.5 1.2 10.7 3.8 121 12 135 305 -2.4 0 -2 -2.7 02/11/2006 10:30:00 7.1 1.2 10.3 4.6 6.7 1.3 9.9 4.2 120 12 116 305 -2.4 0 -2 -2.4 02/11/2006 10:40:00 6.2 1.6 11.1 2.3 5.7 1.5 10.3 2.3 120 15 103 305 -2.4 0 -2 -2.4 02/11/2006 10:50:00 4.9 1.1 9.1 2.6 4.4 1.2 8 0.7 124 15 127 305 -2.3 0 -2 -2.4 02/11/2006 11:00:00 3.7 1.2 7.2 0.4 3.1 1.3 6.1 0.4 118 20 117 305 -2.3 0 -1.8 -2.4 02/11/2006 11:10:00 4.4 1.5 8.4 1.1 3.9 1.6 8.4 0.4 122 22 162 305 -2.2 0 -1.8 -2.4 02/11/2006 11:20:00 6.4 1.7 10.3 2.3 6 1.7 9.9 2.3 134 11 137 305 -2.2 0 -1.8 -2.2 02/11/2006 11:30:00 7.7 1.2 11.5 4.2 7.4 1.1 10.3 4.6 141 9 133 305 -2.2 0 -1.8 -2.2 02/11/2006 11:40:00 6.9 1.3 10.3 3.8 7 1.2 10.3 4.2 151 12 169 305 -2.1 0 -2 -2.2 02/11/2006 11:50:00 7.8 1.7 13 3.8 8 1.4 12.6 4.9 155 12 152 305 -2 0 -1.8 -2.2 02/11/2006 12:00:00 7.9 1.7 11.8 4.9 8.7 1.3 12.6 5.3 160 11 144 305 -2 0 -1.8 -2 02/11/2006 12:10:00 7.5 1.5 12.2 4.2 9.1 1.2 12.6 5.3 163 8 149 305 -2 0 -1.8 -2 02/11/2006 12:20:00 7.3 1.5 11.1 3.4 7.6 1.3 11.5 3 157 11 154 305 -1.9 0 -1.8 -2 02/11/2006 12:30:00 6.2 1.2 9.5 3.4 7.9 1.3 11.1 4.2 168 10 163 305 -1.9 0 -1.5 -2 02/11/2006 12:40:00 7.7 1.3 10.7 3.8 8.1 1.1 10.7 5.7 185 7 194 305 -2.4 0.2 -1.8 -2.7 02/11/2006 12:50:00 8.1 1.2 10.7 5.3 8 1.2 10.7 5.3 188 5 190 305 -2.8 0 -2.2 -3.1 02/11/2006 13:00:00 9 0.7 10.7 6.8 8.8 0.8 10.3 6.5 190 4 191 305 -3 0 -2.4 -3.1 02/11/2006 13:10:00 8.9 1.2 11.8 4.9 9.7 1 12.2 7.2 183 5 181 305 -3.1 0 -3.1 -3.3 02/11/2006 13:20:00 9.8 1 12.6 6.8 10.2 0.9 12.2 7.2 184 3 180 305 -3.3 0 -3.1 -3.3 02/11/2006 13:30:00 10.7 1 13 8 10.8 0.9 12.6 8.4 187 3 192 305 -3.3 0 -3.1 -3.3 02/11/2006 13:40:00 11.8 0.8 13.7 8.4 11.8 0.8 14.1 9.5 186 3 186 305 -3.3 0 -3.3 -3.3 02/11/2006 13:50:00 12.5 1 14.9 10.3 12.7 0.9 14.9 10.3 185 3 187 305 -3.4 0 -3.3 -3.6 02/11/2006 14:00:00 11.8 1 14.1 9.1 12.2 0.9 14.1 9.1 185 3 186 305 -3.6 0 -3.3 -3.8 02/11/2006 14:10:00 11.5 1 13.7 8.4 11.2 1 13.3 8 188 4 191 305 -3.6 0 -3.3 -3.8 02/11/2006 14:20:00 11.4 0.8 13.3 8.8 10.7 1 13 7.2 192 4 194 305 -3.5 0 -3.1 -3.6 02/11/2006 14:30:00 10.4 0.8 12.2 8 10 1 12.2 7.2 190 3 190 305 -3.6 0 -3.1 -3.8 02/11/2006 14:40:00 9.6 1.2 12.6 4.6 9.2 1.1 11.8 6.5 189 5 198 305 -3.6 0 -3.1 -3.8 02/11/2006 14:50:00 8.7 1.5 13 4.9 8.8 1.2 12.6 6.5 185 6 194 305 -3.7 0 -3.3 -3.8 02/11/2006 15:00:00 10.5 1.2 13.3 5.7 10.1 1.1 13.7 7.6 193 6 189 305 -3.8 0 -3.8 -3.8 02/11/2006 15:10:00 12.2 1.1 14.9 9.5 11.3 1.1 13.7 8 203 5 207 305 -3.9 0 -3.8 -4 02/11/2006 15:20:00 13.6 1.3 15.6 9.1 12.7 1.3 15.3 8.4 205 4 197 305 -3.9 0 -3.3 -4 02/11/2006 15:30:00 13.8 1 16.4 10.7 12.9 1.2 15.6 9.5 203 5 202 305 -3.9 0 -3.3 -4 02/11/2006 15:40:00 14.1 1 16.1 9.5 13.1 1.1 15.3 9.1 204 4 208 305 -4 0 -3.8 -4.2 02/11/2006 15:50:00 14.5 0.8 16.4 11.5 13.5 1 15.3 9.5 206 3 203 305 -4.2 0 -3.8 -4.5 02/11/2006 16:00:00 14.2 1 16.4 11.1 12.9 1.3 15.3 9.1 208 4 208 305 -4.3 0 -3.8 -4.5 02/11/2006 16:10:00 13.9 1.3 16.4 9.9 12.5 1.3 15.3 8.4 208 5 208 305 -4.4 0 -4 -4.7 02/11/2006 16:20:00 13.2 1.3 16.1 9.5 11.9 1.5 14.9 8 213 5 217 305 -4.7 0.1 -4.5 -4.9 02/11/2006 16:30:00 11.9 0.8 13.7 8.8 10.9 0.9 12.6 8 206 7 204 305 -4.8 0 -4.5 -4.9 02/11/2006 16:40:00 11.6 0.7 13 8.4 11 0.9 12.6 7.6 199 6 213 305 -4.9 0 -4.7 -4.9 02/11/2006 16:50:00 11.7 1.1 14.1 9.1 10.9 1.3 13.3 7.2 207 9 199 305 -4.9 0 -4.7 -4.9 02/11/2006 17:00:00 12.5 1 14.5 9.5 11.6 1 13.7 8.8 203 9 205 305 -4.9 0 -4.5 -5.1 02/11/2006 17:10:00 12.6 1.1 14.9 8.8 11.7 1.2 14.1 7.6 207 5 205 305 -5.1 0 -4.7 -5.3 02/11/2006 17:20:00 12.7 1.2 15.6 9.1 11.9 1.2 14.5 8.8 206 9 208 305 -5.2 0.1 -4.5 -5.6 02/11/2006 17:30:00 11.4 0.8 13.7 8.8 10.4 1 13 7.2 212 5 223 305 -5.2 0 -5.1 -5.6 02/11/2006 17:40:00 10.7 0.9 13 8.4 9.8 1.1 12.2 6.8 209 5 214 305 -5 0 -4.5 -5.1 02/11/2006 17:50:00 11 0.8 13 8 10.2 1 12.2 7.2 210 4 216 305 -4.9 0 -4.5 -5.1 02/11/2006 18:00:00 10.6 0.9 12.6 7.2 9.7 1 12.2 6.5 208 5 210 305 -4.9 0 -4.7 -4.9 02/11/2006 18:10:00 9.1 1.7 12.6 4.9 8.3 1.6 11.8 4.9 207 7 208 305 -4.9 0 -4.7 -4.9 02/11/2006 18:20:00 9.4 1.5 11.5 6.1 9.1 1.4 11.1 5.7 196 5 196 305 -5 0.1 -4.7 -5.6 02/11/2006 18:30:00 8 0.6 9.9 5.7 8.1 0.8 9.9 4.9 186 3 190 305 -5.9 0.1 -5.6 -6.2 02/11/2006 18:40:00 8.6 0.7 9.9 6.5 8.8 0.6 9.9 7.2 187 3 190 305 -6.3 0.2 -6 -6.9 02/11/2006 18:50:00 9.3 0.4 9.9 8 9.2 0.3 9.9 8 189 2 188 305 -6.5 0 -6 -6.7 02/11/2006 19:00:00 9.3 0.3 9.9 8.4 9.2 0.3 9.9 8.4 190 2 191 305 -6.3 0 -5.8 -6.7 02/11/2006 19:10:00 8.7 0.7 9.9 7.2 8.9 0.5 10.3 7.6 188 3 185 305 -6.3 0.1 -5.8 -6.7 02/11/2006 19:20:00 7.6 0.4 8.8 6.8 7.9 0.3 8.8 6.8 187 3 184 305 -6.4 0 -6 -6.7 02/11/2006 19:30:00 7.7 0.4 8.8 6.8 7.7 0.4 8.8 6.1 188 3 182 305 -6.6 0 -6 -6.7 02/11/2006 19:40:00 8.7 0.5 9.9 7.6 8.7 0.7 10.3 7.2 186 3 184 305 -6.3 0.1 -5.8 -6.7 02/11/2006 19:50:00 9 0.5 10.3 7.6 9.4 0.4 11.1 8.4 185 3 186 305 -5.8 0.1 -5.3 -6.2 02/11/2006 20:00:00 8.2 0.8 10.3 5.7 8.2 1 10.3 5.7 186 5 196 305 -5.6 0 -5.6 -5.8 02/11/2006 20:10:00 8.2 0.6 9.5 6.5 7.7 0.5 9.5 6.1 190 5 190 305 -5.5 0 -5.3 -5.6 02/11/2006 20:20:00 8.4 1 10.7 5.7 7.9 1 9.9 4.9 193 6 200 305 -5.1 0.2 -4.7 -5.6 02/11/2006 20:30:00 8.9 1.3 11.5 6.8 8.4 1.1 11.1 6.1 197 6 207 305 -4.9 0.1 -4.7 -5.1 02/11/2006 20:40:00 9.7 0.5 11.1 8 9.1 0.6 10.7 7.6 202 4 200 305 -4.5 0 -4.5 -4.9 02/11/2006 20:50:00 8.3 1.2 11.5 6.1 7.8 1.1 11.5 5.3 196 7 205 305 -4.7 0.2 -4.2 -5.1 02/11/2006 21:00:00 7.9 0.6 9.9 6.1 8 0.7 9.9 6.1 186 4 193 305 -5.1 0 -4.7 -5.1 02/11/2006 21:10:00 8.5 0.5 9.9 7.2 8.7 0.5 9.9 7.6 186 2 186 305 -5 0 -4.5 -5.1 02/11/2006 21:20:00 7.8 0.4 9.1 6.5 8 0.4 9.1 6.8 187 3 190 305 -5.1 0 -4.9 -5.3 02/11/2006 21:30:00 7.7 0.4 8.8 6.8 7.9 0.3 8.8 6.8 186 3 188 305 -5.1 0 -4.9 -5.1 02/11/2006 21:40:00 8 0.4 8.8 6.8 8.3 0.4 9.5 7.2 185 2 190 305 -5 0 -4.9 -5.1 02/11/2006 21:50:00 7.9 0.4 8.8 6.8 8.1 0.3 9.1 7.6 186 2 187 305 -5.1 0 -4.9 -5.1 02/11/2006 22:00:00 7.8 0.4 8.8 6.8 8 0.3 8.8 6.8 186 2 186 305 -5 0 -4.9 -5.3 02/11/2006 22:10:00 7.9 0.4 8.4 6.8 8 0.4 8.8 6.8 186 2 188 305 -5 0 -4.9 -5.1 02/11/2006 22:20:00 8 0.5 8.8 6.1 8.2 0.4 9.1 6.8 184 2 188 305 -5 0 -4.9 -5.1 02/11/2006 22:30:00 7.7 0.4 8.8 6.5 8 0.4 8.8 6.8 184 2 188 305 -5.1 0 -4.9 -5.1 02/11/2006 22:40:00 7.8 0.6 9.1 4.9 8.2 0.5 9.1 6.8 183 2 187 305 -5.1 0 -4.9 -5.3 02/11/2006 22:50:00 8.2 0.4 8.8 6.1 8.5 0.3 9.5 7.6 184 2 184 305 -5.1 0 -4.9 -5.3 02/11/2006 23:00:00 8.3 0.4 9.1 6.8 8.6 0.4 9.5 7.6 184 2 186 305 -5.1 0 -4.9 -5.3 02/11/2006 23:10:00 8.2 0.5 9.5 6.5 8.7 0.4 9.5 7.6 183 2 183 305 -5.2 0 -5.1 -5.3 02/11/2006 23:20:00 8 0.4 8.8 6.8 8.3 0.4 9.1 6.8 185 3 183 305 -5.4 0 -5.1 -5.8 02/11/2006 23:30:00 7.9 0.4 9.1 6.8 8.1 0.3 8.8 7.2 185 2 183 305 -5.7 0 -5.1 -5.8 02/11/2006 23:40:00 8.2 0.3 9.1 7.2 8.4 0.3 9.1 7.6 185 2 189 305 -5.6 0 -5.6 -5.8 02/11/2006 23:50:00 8 0.4 8.8 6.8 8.1 0.3 9.1 7.2 185 2 192 305 -5.5 0 -5.6 -5.8 02/12/2006 00:00:00 7.7 0.4 8.8 6.5 7.9 0.3 8.8 7.2 186 3 187 305 -5.5 0 -5.3 -5.8 02/12/2006 00:10:00 8.1 0.4 9.5 7.2 8.3 0.4 9.1 7.6 186 2 189 305 -5.6 0 -5.6 -5.8 02/12/2006 00:20:00 8.6 0.5 10.3 7.6 8.8 0.4 9.9 8 184 2 186 305 -5.6 0 -5.6 -5.8 02/12/2006 00:30:00 8.9 0.4 9.9 7.6 9 0.3 9.5 8 186 2 186 305 -5.9 0.1 -5.6 -6.2 02/12/2006 00:40:00 8.9 0.4 9.9 8 9 0.4 10.3 8 188 3 189 305 -6.1 0 -6 -6.2 02/12/2006 00:50:00 8.6 0.9 10.7 6.5 8.2 0.8 10.7 5.7 193 5 200 305 -6 0 -5.6 -6.2 02/12/2006 01:00:00 9.3 0.8 11.1 6.5 8.6 0.9 10.7 5.7 196 4 192 305 -5.6 0.1 -5.3 -6 02/12/2006 01:10:00 9.2 0.9 11.1 6.8 8.6 0.9 11.1 5.7 194 4 193 305 -6 0 -5.8 -6.2 02/12/2006 01:20:00 9.4 1.5 11.5 5.7 8.8 1.5 11.5 5.7 197 8 204 305 -6 0.1 -5.8 -6.4 02/12/2006 01:30:00 8 0.6 9.5 6.1 7.7 0.5 8.8 6.5 190 5 194 305 -6.8 0.1 -6.2 -7.1 02/12/2006 01:40:00 8.4 1.3 10.7 6.1 7.9 1.2 10.3 5.3 196 7 205 305 -6.6 0.2 -6.2 -6.9 02/12/2006 01:50:00 6.9 0.8 8.8 3.8 6.9 0.9 8.8 4.9 187 7 197 305 -7 0.1 -6.7 -7.1 02/12/2006 02:00:00 8.2 0.6 9.5 6.5 8.1 0.6 9.5 5.7 191 3 186 305 -6.9 0 -6.7 -7.1 02/12/2006 02:10:00 8.1 0.3 9.1 7.2 8.1 0.4 9.1 6.5 191 3 196 305 -7.1 0 -6.9 -7.3 02/12/2006 02:20:00 8.6 0.3 9.5 7.6 8.5 0.4 9.5 6.5 192 3 194 305 -7.4 0.1 -7.1 -7.5 02/12/2006 02:30:00 8.4 0.3 9.1 7.6 8.3 0.4 9.1 7.2 192 2 198 305 -7.7 0 -7.3 -7.9 02/12/2006 02:40:00 8.2 0.3 9.1 7.2 8.2 0.4 9.1 6.8 192 2 196 305 -7.9 0.1 -7.7 -8.2 02/12/2006 02:50:00 7.8 0.4 8.8 6.8 7.7 0.4 9.1 6.1 192 3 194 305 -8.1 0.1 -7.7 -8.2 02/12/2006 03:00:00 8.5 0.5 9.5 7.2 8.6 0.5 9.9 7.2 189 2 189 305 -8.3 0 -7.9 -8.4 02/12/2006 03:10:00 8.2 0.4 9.5 7.2 8.2 0.5 9.1 6.8 191 2 196 305 -8.2 0 -7.7 -8.4 02/12/2006 03:20:00 7.7 0.3 8.4 7.2 7.7 0.3 8.4 6.5 191 3 189 305 -8.2 0 -7.7 -8.4 02/12/2006 03:30:00 8 0.3 9.1 7.2 8.1 0.4 9.1 7.2 192 2 194 305 -8.2 0 -7.7 -8.4 02/12/2006 03:40:00 8 0.4 9.1 7.2 8.1 0.4 9.1 6.5 191 3 184 305 -8.2 0 -7.9 -8.4 02/12/2006 03:50:00 8.2 0.3 9.1 6.8 8.2 0.3 9.1 7.2 187 2 187 305 -8.3 0 -7.9 -8.6 02/12/2006 04:00:00 7.6 0.5 8.4 5.7 7.7 0.4 8.8 6.1 185 2 186 305 -8.3 0 -8.2 -8.6 02/12/2006 04:10:00 6.5 1 8 3 6.8 0.8 8 4.2 182 4 184 305 -8.2 0.1 -7.9 -8.4 02/12/2006 04:20:00 7.1 0.8 8.4 3.8 7.2 0.7 8 4.9 184 3 186 305 -8.2 0 -7.9 -8.4 02/12/2006 04:30:00 7.8 0.3 8.8 7.2 7.8 0.4 8.8 6.8 187 2 188 305 -8.3 0 -8.2 -8.4 02/12/2006 04:40:00 6.6 1.3 8.4 2.6 6.9 1 8.4 4.6 184 6 189 305 -8.3 0 -7.9 -8.6 02/12/2006 04:50:00 5.7 1 8 2.6 5.9 0.8 8 4.6 182 6 188 305 -8.3 0 -8.2 -8.4 02/12/2006 05:00:00 3.9 0.9 7.2 1.9 5.1 0.7 6.8 3.4 170 8 179 305 -8.5 0 -8.4 -8.8 02/12/2006 05:10:00 4.5 0.9 6.8 2.6 5.7 0.6 7.2 3.4 163 7 163 305 -8.3 0 -8.2 -8.4 02/12/2006 05:20:00 4.7 1 7.6 2.3 5.4 0.7 7.2 3 162 8 157 305 -8.4 0 -8.2 -8.6 02/12/2006 05:30:00 4 0.8 6.8 2.3 4.9 0.8 6.8 2.3 168 10 151 305 -8.2 0 -7.9 -8.4 02/12/2006 05:40:00 3.6 0.7 5.3 1.9 4.5 0.6 6.5 3 172 9 158 305 -8 0.1 -7.7 -8.4 02/12/2006 05:50:00 3.7 0.6 6.1 2.3 4.6 0.6 6.5 2.3 170 9 189 305 -8 0.1 -7.7 -8.2 02/12/2006 06:00:00 4 0.8 6.1 1.9 4.9 0.8 6.8 2.6 170 9 179 305 -7.8 0.2 -7.3 -8.2 02/12/2006 06:10:00 4.1 0.9 7.2 2.3 5 0.8 7.2 2.6 165 9 155 305 -8.2 0.5 -7.5 -9 02/12/2006 06:20:00 4.8 1 7.2 2.3 5.9 0.7 7.6 3.4 164 9 156 305 -9.3 0.2 -8.8 -9.8 02/12/2006 06:30:00 4.6 0.9 7.6 3 6.6 0.5 8 5.3 166 6 157 305 -9.8 0 -9.6 -10 02/12/2006 06:40:00 5.5 1 8 3.4 7.3 0.5 8.8 5.3 163 6 159 305 -9.9 0 -9.4 -10 02/12/2006 06:50:00 6.1 1.3 9.5 3.4 7.8 0.5 9.1 6.5 162 6 159 305 -10 0.2 -9.4 -10.4 02/12/2006 07:00:00 7.5 1.2 9.5 4.6 8.5 0.5 9.5 7.2 158 6 157 305 -10.8 0.1 -10.4 -11.1 02/12/2006 07:10:00 7.9 1.3 10.3 4.6 9.1 0.5 10.3 7.2 157 7 151 305 -11.1 0 -10.9 -11.3 02/12/2006 07:20:00 8.2 1 9.9 4.6 9.1 0.5 10.3 7.6 156 6 154 305 -11 0 -10.4 -11.3 02/12/2006 07:30:00 7.6 1.1 9.9 4.2 8.7 0.6 9.9 6.5 156 7 154 305 -10.9 0 -10.4 -11.1 02/12/2006 07:40:00 7.2 1.1 9.5 4.2 8.3 0.6 10.3 6.5 157 7 145 305 -10.8 0 -10.4 -10.9 02/12/2006 07:50:00 7.8 0.9 9.9 4.6 8.5 0.5 9.5 6.8 152 6 142 305 -10.6 0 -10 -10.9 02/12/2006 08:00:00 8.6 0.9 10.7 4.9 9 0.5 9.9 6.5 149 5 149 305 -10.5 0 -10.4 -10.9 02/12/2006 08:10:00 9.9 0.8 11.1 6.5 9.8 0.5 10.7 8 144 4 143 305 -10.4 0 -10.4 -10.9 02/12/2006 08:20:00 9.7 0.6 11.1 7.6 9.6 0.4 10.3 8.4 146 3 146 305 -10.7 0 -10.4 -10.9 02/12/2006 08:30:00 10.4 0.5 11.5 9.1 9.8 0.4 10.7 8.4 144 2 143 305 -10.8 0 -10.7 -10.9 02/12/2006 08:40:00 10.7 0.4 11.5 9.5 9.9 0.3 10.3 8.8 143 1 143 305 -10.8 0 -10.7 -10.9 02/12/2006 08:50:00 10.5 0.5 11.5 9.1 10 0.3 10.7 9.1 142 1 142 305 -11 0.1 -10.9 -11.3 02/12/2006 09:00:00 11 0.6 12.2 9.5 10.3 0.3 11.1 9.1 141 1 142 305 -11.2 0 -10.7 -11.5 02/12/2006 09:10:00 12 0.3 12.6 11.1 10.4 0.3 11.1 9.1 141 1 141 305 -11 0 -10.4 -11.3 02/12/2006 09:20:00 11.8 0.3 12.6 10.7 10.2 0.3 10.7 9.1 141 1 142 305 -10.8 0.1 -10.4 -11.1 02/12/2006 09:30:00 11.4 0.4 12.2 10.3 10 0.4 11.1 9.1 139 2 137 305 -10.4 0 -10 -10.7 02/12/2006 09:40:00 11 0.5 12.2 9.9 9.9 0.4 11.1 8.8 138 2 139 305 -10.2 0 -10 -10.4 02/12/2006 09:50:00 11.5 0.4 12.6 10.3 10.1 0.4 11.1 9.1 139 2 141 305 -10.3 0 -10 -10.7 02/12/2006 10:00:00 11.1 0.4 12.2 9.9 9.8 0.4 10.7 8.4 141 2 143 305 -10.5 0 -10.2 -10.9 02/12/2006 10:10:00 11.6 0.3 12.6 10.7 10.1 0.4 11.1 9.1 142 2 144 305 -10.5 0 -10.2 -10.9 02/12/2006 10:20:00 11.8 0.3 12.6 11.1 10.2 0.4 11.1 8.8 141 1 141 305 -10.5 0 -10.4 -10.7 02/12/2006 10:30:00 12.1 0.4 13 10.7 10.4 0.3 11.1 9.5 140 1 141 305 -10.5 0 -10.4 -10.9 02/12/2006 10:40:00 12.2 0.4 13 10.7 10.6 0.4 11.5 9.5 140 2 141 305 -10.5 0 -10.2 -10.7 02/12/2006 10:50:00 12.3 0.4 13.3 11.1 10.8 0.4 11.8 9.5 139 1 141 305 -10.4 0 -10.4 -10.9 02/12/2006 11:00:00 11.9 0.3 12.6 11.1 10.7 0.4 11.5 9.9 138 1 137 305 -10.9 0 -10.7 -11.1 02/12/2006 11:10:00 11.5 0.3 12.2 11.1 10.6 0.3 11.1 9.5 138 1 138 305 -10.9 0 -10.9 -11.1 02/12/2006 11:20:00 11.2 0.3 11.8 10.3 10.2 0.3 10.7 9.1 138 2 140 305 -10.8 0 -10.7 -10.9 02/12/2006 11:30:00 11 0.3 11.8 10.3 10.1 0.3 11.1 9.1 137 2 133 305 -10.8 0 -10.4 -10.9 02/12/2006 11:40:00 11.3 0.3 11.8 10.3 10.2 0.2 10.7 9.5 141 1 141 305 -10.9 0 -10.4 -11.1 02/12/2006 11:50:00 11.8 0.3 12.2 11.1 10.5 0.2 11.1 9.5 141 1 141 305 -10.7 0 -10.4 -10.9 02/12/2006 12:00:00 10.6 0.5 11.8 9.5 9.8 0.5 10.7 8.8 139 1 138 305 -10.4 0.1 -10 -10.9 02/12/2006 12:10:00 10.2 0.5 11.5 8.4 9.5 0.6 11.1 7.2 136 3 135 305 -9.6 0.4 -8.8 -10.2 02/12/2006 12:20:00 10.2 0.6 11.8 8.4 9.6 0.6 11.1 7.6 134 4 139 305 -8.8 0 -8.4 -9 02/12/2006 12:30:00 10.1 0.5 11.5 8.4 9.6 0.6 11.1 7.6 131 4 129 305 -8.6 0.1 -8.2 -8.8 02/12/2006 12:40:00 10.1 0.6 12.2 8.4 9.8 0.6 11.5 8.4 128 5 126 305 -8.5 0 -8.2 -8.8 02/12/2006 12:50:00 11 0.5 11.8 8.8 10.5 0.5 11.8 8.8 133 4 129 305 -8.2 0 -7.7 -8.4 02/12/2006 13:00:00 11.9 0.4 12.6 10.7 11.1 0.4 11.8 9.1 139 1 140 305 -8.3 0 -7.9 -8.6 02/12/2006 13:10:00 10.5 0.6 11.8 8.4 9.9 0.5 11.1 8.4 136 3 139 305 -8.2 0.1 -7.7 -8.4 02/12/2006 13:20:00 10.2 0.6 12.2 8.4 9.8 0.6 11.8 7.2 135 4 126 305 -7.8 0.1 -7.5 -8.2 02/12/2006 13:30:00 11.1 0.9 13.3 8 10.6 1 12.6 7.2 135 5 143 305 -7.5 0.1 -6.9 -7.7 02/12/2006 13:40:00 12.2 0.6 13.3 9.5 11.8 0.6 13 9.5 136 3 133 305 -7.1 0 -6.7 -7.3 02/12/2006 13:50:00 12.1 0.8 13.7 9.9 11.7 0.8 13.3 9.9 133 4 131 305 -6.8 0 -6.4 -7.1 02/12/2006 14:00:00 12.1 0.8 13.3 8.8 11.7 0.8 13.3 9.1 132 4 136 305 -6.8 0.2 -6.4 -7.1 02/12/2006 14:10:00 11.5 0.7 12.6 8 11.1 0.7 12.6 8.8 133 3 131 305 -7.1 0 -6.9 -7.3 02/12/2006 14:20:00 10.9 0.7 12.2 8.8 10.4 0.7 12.2 8 134 4 131 305 -7.2 0 -6.9 -7.5 02/12/2006 14:30:00 10.6 0.5 11.5 9.1 10.2 0.5 11.5 8.4 134 3 134 305 -7.4 0 -7.1 -7.5 02/12/2006 14:40:00 10.2 0.9 11.8 8 9.9 0.8 11.8 7.2 131 5 134 305 -7 0.1 -6.7 -7.1 02/12/2006 14:50:00 10.3 1.3 14.9 7.6 10.1 1.3 14.5 6.8 131 8 131 305 -7.1 0 -6.7 -7.5 02/12/2006 15:00:00 10.6 1.6 14.9 6.1 10.2 1.5 14.1 6.5 129 9 138 305 -7.4 0 -7.1 -7.7 02/12/2006 15:10:00 9.8 1.4 12.6 6.5 9.5 1.3 12.6 5.7 132 9 138 305 -7.4 0 -7.1 -7.7 02/12/2006 15:20:00 10.3 0.7 11.8 7.6 9.9 0.7 11.8 8 137 4 139 305 -7.3 0 -6.9 -7.5 02/12/2006 15:30:00 8.3 1.4 10.7 5.3 7.9 1.5 11.5 4.2 127 9 131 305 -7.2 0 -7.1 -7.3 02/12/2006 15:40:00 6.8 1 9.9 4.6 6.6 1 9.1 3.8 124 12 126 305 -7.4 0 -7.1 -7.5 02/12/2006 15:50:00 6.4 1.3 9.9 4.2 6 1.3 9.9 3 123 13 106 305 -7.5 0 -7.3 -7.7 02/12/2006 16:00:00 5.8 1.2 8.4 3 5.3 1.3 8.4 2.6 121 16 133 305 -7.4 0 -7.1 -7.5 02/12/2006 16:10:00 5.8 1 8.4 2.6 5.5 1 8 3 132 12 138 305 -7.2 0 -7.1 -7.3 02/12/2006 16:20:00 5.1 1.1 7.6 3 4.7 1.2 7.6 0.4 133 15 124 305 -7.2 0 -6.9 -7.5 02/12/2006 16:30:00 6.5 1.1 9.5 4.2 5.8 1.2 8.8 2.3 127 13 128 305 -7.5 0 -7.3 -7.7 02/12/2006 16:40:00 4.4 1.4 8.4 0.7 3.7 1.5 8.4 0.4 122 29 137 305 -7.4 0 -7.1 -7.7 02/12/2006 16:50:00 2.1 1.5 8.4 0.4 1.4 1.5 8 0.4 100 69 129 305 -7.4 0.1 -7.1 -7.7 02/12/2006 17:00:00 9 1.9 13 4.6 8.8 1.9 13.7 4.2 127 15 119 305 -6.9 0.3 -6.7 -7.5 02/12/2006 17:10:00 8.8 1.4 12.2 3.4 8.3 1.3 11.8 4.6 117 13 121 305 -6.8 0 -6.7 -7.1 02/12/2006 17:20:00 7.3 1.6 11.1 3 6.6 1.6 10.7 2.6 100 17 106 305 -7.1 0.1 -6.7 -7.5 02/12/2006 17:30:00 5.9 1.8 10.7 1.9 5.3 1.8 9.9 1.5 90 20 78 305 -7.6 0 -7.3 -7.7 02/12/2006 17:40:00 5 1.8 11.5 1.1 4.5 2.1 11.1 0.4 90 27 112 305 -7.7 0 -7.5 -7.9 02/12/2006 17:50:00 5.8 1.7 12.2 1.9 5.1 1.7 11.5 2.3 93 22 144 305 -7.8 0 -7.5 -7.9 02/12/2006 18:00:00 7.8 1.6 12.6 3 7 1.7 13.3 3.4 101 20 117 305 -7.6 0.1 -7.3 -7.9 02/12/2006 18:10:00 7.1 1.7 11.8 3 6.4 1.5 10.7 2.6 101 16 124 305 -7.4 0 -7.1 -7.7 02/12/2006 18:20:00 7 1.2 10.7 4.2 6.5 1.3 10.7 3.4 98 16 89 305 -7.2 0 -6.9 -7.5 02/12/2006 18:30:00 6.8 1.5 13.3 3.4 6.2 1.5 11.5 2.6 98 19 95 305 -7.2 0 -6.9 -7.3 02/12/2006 18:40:00 7.5 1.7 13.3 3 7 1.9 13.7 1.9 86 19 87 305 -7.4 0.1 -7.1 -7.7 02/12/2006 18:50:00 8.3 2 14.1 3.8 7.8 2.1 13 2.6 99 19 126 305 -7.3 0 -7.1 -7.5 02/12/2006 19:00:00 7.9 1.9 13.7 3 7.5 1.9 14.1 3.8 99 17 109 305 -7.2 0 -6.9 -7.3 02/12/2006 19:10:00 8.1 1.7 14.5 4.6 7.8 1.7 14.9 4.2 102 20 121 305 -7.4 0 -7.1 -7.7 02/12/2006 19:20:00 8.4 1.5 13.3 4.9 7.8 1.5 13.3 4.2 105 17 98 305 -7.3 0 -7.1 -7.5 02/12/2006 19:30:00 7.4 2 14.9 2.3 6.9 2 13 2.3 100 23 103 305 -7 0 -6.7 -7.1 02/12/2006 19:40:00 7.5 1.7 12.2 3.4 6.9 1.7 12.6 3.4 91 18 77 305 -6.9 0.1 -6.7 -7.1 02/12/2006 19:50:00 7.8 2.1 15.6 3.4 7.3 2.1 14.9 2.6 85 17 108 305 -7.2 0 -6.9 -7.5 02/12/2006 20:00:00 7.6 1.7 13 3.8 7.2 1.7 11.8 3.4 97 20 97 305 -7 0.1 -6.7 -7.3 02/12/2006 20:10:00 7.6 1.9 13 3.4 7.1 1.9 12.2 2.3 100 22 83 305 -6.8 0 -6.7 -6.9 02/12/2006 20:20:00 10.2 2.6 17.6 3.8 9.7 2.8 17.2 3.4 118 17 133 305 -6.6 0.1 -6.2 -6.9 02/12/2006 20:30:00 13 2.1 19.5 7.2 12.6 2.2 18.7 7.2 123 11 131 305 -6.4 0 -6.2 -6.7 02/12/2006 20:40:00 11.7 1.9 16.4 6.5 11.2 1.8 15.6 6.5 114 11 112 305 -6.5 0 -6.2 -6.7 02/12/2006 20:50:00 11.3 1.9 17.2 5.3 10.6 2 17.9 5.3 110 12 112 305 -6.6 0 -6.4 -6.9 02/12/2006 21:00:00 8.9 2.1 14.5 4.2 8.4 2.2 14.1 3.4 110 17 95 305 -6.6 0 -6.4 -6.9 02/12/2006 21:10:00 7.1 1.7 14.1 3.8 6.5 1.7 12.6 3 105 17 103 305 -6.7 0 -6.4 -6.9 02/12/2006 21:20:00 7.8 1.9 14.1 4.2 7.4 1.8 12.6 3.8 109 17 93 305 -6.7 0 -6.7 -6.9 02/12/2006 21:30:00 8 1.7 13.7 3.8 7.7 1.7 14.1 4.2 118 16 133 305 -6.5 0 -6.2 -6.7 02/12/2006 21:40:00 9.9 1.8 16.1 5.3 9.4 1.7 13.7 5.3 118 15 103 305 -6.3 0 -6 -6.7 02/12/2006 21:50:00 9.3 2 15.3 5.7 8.8 1.9 14.9 5.3 115 17 121 305 -6 0 -5.6 -6.2 02/12/2006 22:00:00 8.1 1.7 13 3.4 7.6 1.7 12.2 3 103 18 74 305 -5.9 0 -5.6 -6 02/12/2006 22:10:00 6.7 2 13.7 2.6 6.1 2 13 0.7 100 19 89 305 -6.2 0 -5.8 -6.4 02/12/2006 22:20:00 7.5 1.9 13.7 3.4 7.3 2 13 2.6 66 17 56 305 -6.5 0.1 -6 -6.9 02/12/2006 22:30:00 7.5 2.2 15.6 2.3 7.1 2.4 14.9 2.6 67 19 47 305 -6.8 0.1 -6.4 -7.1 02/12/2006 22:40:00 8.4 2 12.6 2.6 8.3 2 13.7 3.4 67 13 72 305 -6.9 0.1 -6.7 -7.1 02/12/2006 22:50:00 7.2 2.1 12.6 3 6.8 2.3 11.8 1.9 76 24 64 305 -6.7 0.1 -6.4 -6.9 02/12/2006 23:00:00 7.6 1.8 13 3 7.1 1.8 13 3 112 23 150 305 -6.2 0.1 -6 -6.7 02/12/2006 23:10:00 8.4 2 13.7 3.4 8.1 1.9 13.3 3.8 106 20 115 305 -5.7 0.1 -5.3 -6 02/12/2006 23:20:00 7.8 2.6 16.8 2.6 7.2 2.5 16.4 2.6 103 20 116 305 -5.5 0 -5.1 -5.8 02/12/2006 23:30:00 8.5 2.4 14.9 3.8 7.9 2.4 14.5 3.4 107 18 113 305 -5.6 0 -5.3 -5.8 02/12/2006 23:40:00 8.6 2.2 14.5 3.4 8.2 2.3 15.3 2.6 79 22 50 305 -5.7 0 -5.6 -5.8 02/12/2006 23:50:00 9.1 2.2 15.3 4.2 8.7 2.4 15.6 3.8 80 20 66 305 -5.7 0 -5.6 -6 02/13/2006 00:00:00 10.3 2.6 18.3 4.6 9.8 2.7 17.9 4.2 84 18 70 305 -5.8 0.1 -5.3 -6 02/13/2006 00:10:00 10.7 2.7 18.7 4.2 10.2 2.7 17.6 4.6 79 17 75 305 -6.1 0 -5.8 -6.2 02/13/2006 00:20:00 10.6 2.2 16.8 5.3 10.4 2.4 16.8 4.6 74 16 79 305 -6.4 0.1 -6 -6.7 02/13/2006 00:30:00 9.8 2.5 16.4 4.9 9.3 2.7 17.6 3.4 83 18 71 305 -6.7 0 -6.4 -6.9 02/13/2006 00:40:00 9.3 2.4 14.9 3.4 9 2.6 15.3 3 81 17 72 305 -6.9 0 -6.7 -7.1 02/13/2006 00:50:00 9 1.8 13.7 4.6 8.4 2 13.7 3.8 87 20 79 305 -6.7 0 -6.7 -6.9 02/13/2006 01:00:00 10.3 2.1 14.5 4.9 9.9 2.2 15.3 4.6 78 14 66 305 -6.6 0 -6.4 -6.9 02/13/2006 01:10:00 11.4 1.1 14.5 8.8 11.1 1.2 14.9 7.6 77 7 81 305 -6.6 0 -6.4 -6.7 02/13/2006 01:20:00 10.2 1.5 13.3 4.9 10.2 1.5 14.1 6.5 72 10 74 305 -6.6 0 -6.4 -6.9 02/13/2006 01:30:00 8 2.3 16.1 3.8 7.9 2.3 16.8 3.4 69 18 90 305 -6.7 0 -6.4 -6.9 02/13/2006 01:40:00 8.7 2.2 17.2 3.8 8.4 2.2 16.4 3.4 67 17 68 305 -6.4 0.1 -6 -6.7 02/13/2006 01:50:00 8.4 1.9 14.1 3.8 8.5 2.1 13.7 3.4 67 14 65 305 -6.9 0.1 -6.7 -7.1 02/13/2006 02:00:00 7.1 2.5 14.5 2.3 6.8 2.4 14.9 2.6 90 29 73 305 -6.8 0.2 -6.2 -7.1 02/13/2006 02:10:00 8.7 2.2 14.9 4.6 8.3 2.2 14.1 3.8 110 17 98 305 -5.9 0.2 -5.6 -6.4 02/13/2006 02:20:00 10.5 2.6 19.5 4.2 10 2.5 18.7 3.4 111 17 111 305 -5.8 0.2 -5.3 -6.2 02/13/2006 02:30:00 9.6 2.5 16.8 4.2 9.3 2.6 17.6 3.8 116 19 117 305 -6.4 0.1 -6 -6.9 02/13/2006 02:40:00 10.2 2.8 16.4 3.8 9.7 2.7 16.8 3.4 111 19 86 305 -6.8 0 -6.7 -6.9 02/13/2006 02:50:00 10.3 2.2 17.2 5.7 9.8 2.4 16.1 3.8 110 15 120 305 -7 0.1 -6.7 -7.1 02/13/2006 03:00:00 11.1 2.3 17.2 4.2 10.6 2.3 16.8 4.9 116 18 119 305 -7.1 0 -6.9 -7.1 02/13/2006 03:10:00 11.5 2.5 19.5 5.3 11.1 2.5 17.9 5.7 116 17 136 305 -7.1 0 -6.9 -7.3 02/13/2006 03:20:00 11.4 2.5 18.3 6.1 10.8 2.5 17.9 6.1 115 17 106 305 -7.1 0 -6.9 -7.3 02/13/2006 03:30:00 11.4 1.9 17.2 6.8 11.1 1.8 16.1 7.2 114 16 108 305 -7.1 0 -6.9 -7.3 02/13/2006 03:40:00 10.4 1.7 14.9 5.3 9.9 1.7 14.5 4.9 111 16 113 305 -7.1 0 -6.9 -7.1 02/13/2006 03:50:00 10.8 2.6 16.8 4.2 10.3 2.5 17.2 5.7 115 13 117 305 -7.1 0 -6.9 -7.1 02/13/2006 04:00:00 10.8 2.1 16.8 5.7 10.3 2.1 16.1 5.3 113 17 127 305 -7.1 0 -6.9 -7.1 02/13/2006 04:10:00 10.8 2 17.9 6.5 10.5 1.9 16.4 6.1 116 17 124 305 -7.1 0 -6.7 -7.1 02/13/2006 04:20:00 10.3 2.1 15.6 5.7 9.7 2.1 14.1 4.6 117 15 109 305 -7 0 -6.7 -7.1 02/13/2006 04:30:00 12 2.1 17.2 6.8 11.5 2 16.4 6.8 120 15 129 305 -7 0.1 -6.7 -7.1 02/13/2006 04:40:00 12.8 2.7 18.3 6.8 12.3 2.5 17.6 6.1 121 14 118 305 -7 0 -6.7 -7.1 02/13/2006 04:50:00 12.7 2.2 19.1 8 12.1 2.1 18.7 7.2 118 15 99 305 -7 0.1 -6.7 -7.1 02/13/2006 05:00:00 13.1 2.3 19.9 6.8 12.6 2.4 18.7 5.7 118 13 113 305 -7 0.1 -6.7 -7.1 02/13/2006 05:10:00 13.1 2.2 19.1 6.1 12.6 2.2 19.5 6.5 118 13 112 305 -7.1 0 -6.9 -7.1 02/13/2006 05:20:00 13.1 2.4 19.5 8 12.7 2.4 20.6 8 119 13 133 305 -7.1 0 -6.9 -7.1 02/13/2006 05:30:00 12.2 2.3 17.9 7.2 11.6 2.3 17.9 7.2 117 13 112 305 -7.1 0 -6.7 -7.1 02/13/2006 05:40:00 12.8 2.5 18.3 6.8 12.2 2.5 17.9 5.7 118 13 132 305 -7 0 -6.7 -7.1 02/13/2006 05:50:00 13.3 2.2 19.1 8.4 13 2.1 19.5 8 120 15 133 305 -6.9 0 -6.7 -7.1 02/13/2006 06:00:00 11.9 2.1 17.9 6.5 11.6 2.2 17.9 6.1 113 13 135 305 -6.7 0 -6.7 -6.9 02/13/2006 06:10:00 11.3 2.1 17.9 6.5 10.8 2.1 17.2 6.5 111 16 102 305 -6.6 0 -6.4 -6.9 02/13/2006 06:20:00 9.9 2 16.1 6.1 9.5 1.9 15.3 5.3 119 17 116 305 -6.6 0 -6.4 -6.7 02/13/2006 06:30:00 10.2 2.2 15.6 4.2 9.8 2.2 16.1 3.8 124 18 109 305 -6.5 0 -6.2 -6.7 02/13/2006 06:40:00 9.7 2.4 15.3 4.6 9.4 2.4 16.4 3.4 124 15 127 305 -6.5 0 -6.2 -6.7 02/13/2006 06:50:00 10.8 2.3 16.1 4.9 10.6 2.2 16.1 4.6 123 14 127 305 -6.5 0 -6.2 -6.7 02/13/2006 07:00:00 10.5 2.5 18.7 4.6 10.2 2.5 17.9 4.6 122 14 115 305 -6.5 0 -6.2 -6.7 02/13/2006 07:10:00 10.2 2.1 16.1 4.9 9.9 2.2 15.3 4.6 116 16 118 305 -6.5 0 -6.2 -6.7 02/13/2006 07:20:00 11.4 2.3 16.4 6.1 11 2.3 15.6 5.3 114 15 133 305 -6.4 0.1 -6.2 -6.7 02/13/2006 07:30:00 12 2.1 17.6 6.1 11.5 2 17.6 5.7 112 14 98 305 -6.4 0 -6.2 -6.4 02/13/2006 07:40:00 11.7 2.5 16.8 6.1 11.2 2.4 18.7 4.9 114 15 113 305 -6.4 0 -6 -6.7 02/13/2006 07:50:00 12 2.1 17.9 6.1 11.3 2.3 17.6 4.6 112 15 99 305 -6.4 0 -6.2 -6.7 02/13/2006 08:00:00 11.5 2.4 17.9 6.1 11.2 2.2 17.2 6.5 104 15 113 305 -6.3 0 -6.2 -6.4 02/13/2006 08:10:00 10.6 2.2 16.8 4.6 10.1 2.1 17.9 4.9 103 17 75 305 -6.3 0 -6 -6.4 02/13/2006 08:20:00 10.3 1.7 14.9 5.3 9.8 1.7 14.5 6.1 105 17 108 305 -6.2 0 -6 -6.4 02/13/2006 08:30:00 11.5 2.5 17.2 5.3 10.8 2.5 17.6 4.6 107 14 123 305 -6.2 0 -6 -6.4 02/13/2006 08:40:00 11.8 1.7 16.8 7.6 11.4 1.8 16.8 6.1 109 13 110 305 -6.1 0 -5.8 -6.2 02/13/2006 08:50:00 10.5 1.7 15.6 6.1 9.9 1.6 15.3 5.7 113 13 114 305 -6.1 0 -5.8 -6.2 02/13/2006 09:00:00 10.1 1.7 14.9 4.9 9.6 1.8 15.3 4.2 113 14 113 305 -6 0 -5.8 -6 02/13/2006 09:10:00 9.2 1.8 16.4 4.9 8.6 1.8 13.7 4.9 111 17 116 305 -6 0 -5.8 -6 02/13/2006 09:20:00 9.8 2.2 15.3 5.7 9.2 2.2 14.5 4.9 109 17 114 305 -5.9 0.1 -5.6 -6 02/13/2006 09:30:00 8.7 2.1 16.4 4.2 8 2.2 15.6 3.8 100 18 107 305 -5.8 0 -5.6 -6 02/13/2006 09:40:00 10.3 2.1 15.6 5.3 9.7 2.2 15.3 4.9 112 17 119 305 -5.8 0 -5.6 -6 02/13/2006 09:50:00 8.6 1.8 14.1 3.4 7.9 1.7 12.6 4.2 105 18 108 305 -5.8 0 -5.6 -6 02/13/2006 10:00:00 10.4 2 15.3 4.2 9.8 2.1 16.1 4.6 99 15 102 305 -5.7 0 -5.6 -5.8 02/13/2006 10:10:00 11 2.1 17.2 6.1 10.6 2.2 16.4 4.9 93 15 100 305 -5.6 0 -5.3 -5.8 02/13/2006 10:20:00 9.9 1.7 14.5 6.5 9.6 1.8 14.1 5.7 86 13 90 305 -5.5 0 -5.3 -5.8 02/13/2006 10:30:00 10.6 1.7 15.3 5.3 10.4 1.7 14.9 6.1 75 10 75 305 -5.5 0 -5.3 -5.8 02/13/2006 10:40:00 11.5 1.5 16.4 6.1 11.4 1.6 16.4 7.6 77 9 87 305 -5.5 0 -5.1 -5.8 02/13/2006 10:50:00 11.7 1.7 17.2 7.6 11.6 1.7 16.1 7.6 78 10 85 305 -5.5 0 -5.1 -5.6 02/13/2006 11:00:00 11.7 1.5 16.4 8.4 11.5 1.7 16.1 7.6 79 9 81 305 -5.4 0 -5.1 -5.6 02/13/2006 11:10:00 11.2 2.5 17.6 6.1 10.8 2.6 17.2 5.7 82 14 91 305 -5.3 0 -5.1 -5.6 02/13/2006 11:20:00 11.6 2.3 16.4 6.8 11.4 2.4 17.6 6.1 81 15 95 305 -5.1 0 -4.9 -5.3 02/13/2006 11:30:00 11.8 1.8 17.2 6.8 11.6 2.1 17.2 6.5 81 12 78 305 -5 0 -4.7 -5.1 02/13/2006 11:40:00 11 2.3 18.3 5.3 10.7 2.4 17.2 5.7 82 16 88 305 -4.9 0 -4.7 -5.1 02/13/2006 11:50:00 9.8 2.2 16.4 4.9 9.6 2.3 15.3 4.6 74 15 65 305 -4.6 0 -4.5 -4.7 02/13/2006 12:00:00 9.9 2.4 15.3 3.8 9.7 2.6 16.1 3 76 15 70 305 -4.4 0 -4.2 -4.7 02/13/2006 12:10:00 10.4 1.8 16.8 6.1 10.3 1.9 15.6 6.1 78 13 54 305 -4.4 0 -4 -4.5 02/13/2006 12:20:00 10.2 1.5 14.9 6.1 10.1 1.7 16.4 5.3 77 11 60 305 -4.4 0 -4 -4.5 02/13/2006 12:30:00 9.4 1.6 13.7 4.6 9.4 1.7 14.1 5.3 75 13 62 305 -4.4 0 -4.2 -4.5 02/13/2006 12:40:00 10.6 1.3 14.1 8 10.4 1.5 14.5 7.2 79 9 70 305 -4.5 0 -4.5 -4.7 02/13/2006 12:50:00 12.2 1.3 16.4 9.1 12 1.5 16.1 8.4 79 8 82 305 -4.6 0 -4.5 -4.7 02/13/2006 13:00:00 12 2 17.2 6.5 11.8 2.3 17.9 5.7 79 13 74 305 -4.5 0 -4.2 -4.7 02/13/2006 13:10:00 12.2 2.2 18.7 7.2 12 2.4 21 5.3 75 11 90 305 -4.4 0 -4 -4.7 02/13/2006 13:20:00 11.8 1.7 16.1 5.7 11.6 1.7 16.1 7.6 74 9 82 305 -4.2 0 -4 -4.5 02/13/2006 13:30:00 11.3 2.3 19.5 6.8 11.3 2.5 19.9 6.8 74 14 81 305 -4 0 -3.8 -4.2 02/13/2006 13:40:00 12.1 2 18.3 7.6 11.8 2.2 17.9 6.5 72 10 64 305 -3.9 0 -3.6 -4 02/13/2006 13:50:00 13 1.6 17.2 8.8 12.7 1.7 17.2 8.8 76 8 71 305 -3.6 0 -3.3 -3.8 02/13/2006 14:00:00 14.6 1.6 19.1 9.5 14.4 1.7 20.2 9.5 75 8 71 305 -3.7 0 -3.6 -3.8 02/13/2006 14:10:00 15.6 1.5 19.1 12.2 15.4 1.7 19.1 12.2 75 7 75 305 -3.7 0 -3.3 -3.8 02/13/2006 14:20:00 16.1 1.6 20.2 11.8 15.8 1.6 21 11.8 76 7 77 305 -3.6 0 -3.3 -3.8 02/13/2006 14:30:00 15.9 1.4 19.9 12.6 15.4 1.5 19.1 12.6 76 7 75 305 -3.6 0 -3.3 -3.8 02/13/2006 14:40:00 16 1.6 21 12.6 15.7 1.7 19.9 11.1 77 7 76 305 -3.5 0 -3.3 -3.8 02/13/2006 14:50:00 15.8 1.9 20.6 11.1 15.3 2 21 11.1 77 8 81 305 -3.3 0 -3.1 -3.6 02/13/2006 15:00:00 16 1.7 20.6 12.2 15.7 1.8 20.2 11.8 76 8 75 305 -3.3 0 -3.1 -3.3 02/13/2006 15:10:00 17.2 2.3 22.1 11.1 16.7 2.5 23.3 9.9 79 10 67 305 -3 0.2 -2.4 -3.3 02/13/2006 15:20:00 17.4 2.7 24.8 8.4 17 2.8 24.4 8.8 76 9 84 305 -1.4 0.6 0.1 -2.4 02/13/2006 15:30:00 17.5 2.4 26 10.3 17.1 2.5 25.2 11.5 78 9 87 305 1.1 0.6 2.2 0.1 02/13/2006 15:40:00 16.4 2 21 9.1 16 2.2 22.1 8.8 78 8 74 305 2.4 0.3 3.4 1.7 02/13/2006 15:50:00 16.2 2.5 22.6 10.7 16 2.4 23.7 9.9 79 11 80 305 4.2 0.5 5.4 3.2 02/13/2006 16:00:00 17 2.4 24.8 11.1 16.7 2.5 24.8 10.3 78 10 85 305 6 0.5 7.2 5.2 02/13/2006 16:10:00 16.9 2.5 26.8 10.7 16.5 2.6 24.8 10.7 77 10 83 305 7.9 0.3 8.7 6.9 02/13/2006 16:20:00 16.8 2.3 22.6 10.7 16.7 2.6 24.4 10.3 75 11 75 305 9.7 1.1 11.6 7.9 02/13/2006 16:30:00 16.4 3.1 24.8 9.5 16.2 3.1 24.8 8.8 74 11 75 305 10.2 0.4 11.3 9.5 02/13/2006 16:40:00 15.9 2.8 26 9.1 15.9 2.8 24.8 9.5 73 10 71 305 9.9 0.3 10.5 9.2 02/13/2006 16:50:00 15.7 2.9 22.9 7.6 15.6 3.1 22.9 7.6 70 12 71 305 9.6 0.2 10.2 9.2 02/13/2006 17:00:00 14 3.3 24 7.2 13.7 3.8 23.7 5.7 71 16 66 305 8.8 0.3 9.7 8.2 02/13/2006 17:10:00 13.7 3.2 22.1 4.9 13.6 3.3 24.4 4.9 69 17 88 305 8.2 0.1 9.2 7.9 02/13/2006 17:20:00 12.4 3.2 21.4 4.2 12.1 3.3 22.1 5.7 71 18 50 305 7.9 0.1 8.4 7.7 02/13/2006 17:30:00 10.8 3.2 19.5 3.4 10.5 3.2 19.9 4.6 69 19 63 305 7.5 0.1 8.2 7.2 02/13/2006 17:40:00 9.4 3.1 22.1 3 8.7 3.2 22.6 1.5 87 30 85 305 5.6 1.5 7.4 2.9 02/13/2006 17:50:00 8.9 2.6 19.9 2.6 8.5 2.6 20.2 2.3 91 28 131 305 2.3 0.6 3.2 0.6 02/13/2006 18:00:00 8.7 2.8 18.3 2.6 8.1 2.9 18.3 3 96 28 71 305 -0.1 0.5 1.3 -0.8 02/13/2006 18:10:00 9 2.6 16.8 2.6 8.8 2.7 18.3 2.6 86 23 128 305 -0.7 0 -0.6 -0.8 02/13/2006 18:20:00 7.8 2.5 15.6 2.6 7.4 2.4 13.7 2.6 97 29 156 305 -0.2 0.4 1 -0.6 02/13/2006 18:30:00 7.9 3.1 16.4 2.6 7.6 3.1 17.6 1.1 102 28 110 305 -0.4 0.1 0.6 -0.6 02/13/2006 18:40:00 10.1 3.3 21.8 1.9 9.8 3.5 21 0.7 111 28 129 305 -0.2 0 0.1 -0.4 02/13/2006 18:50:00 9.6 2.9 20.6 3 9.2 2.9 20.6 2.3 113 26 126 305 0 0 0.1 -0.1 02/13/2006 19:00:00 9.6 2.8 19.5 1.5 9.1 2.5 16.1 3.4 121 23 96 305 0.1 0.1 0.6 0.1 02/13/2006 19:10:00 9.7 2.5 15.6 4.6 9.3 2.5 16.8 4.2 115 24 57 305 0.2 0 0.8 0.1 02/13/2006 19:20:00 11 2.8 18.3 4.9 10.5 2.7 17.6 4.6 120 20 84 305 0.3 0 0.8 0.3 02/13/2006 19:30:00 10.4 2.6 18.7 4.2 10.1 2.6 17.9 4.9 121 22 135 305 0.4 0 1 0.3 02/13/2006 19:40:00 10.1 2.8 19.1 3.8 10.1 2.9 19.1 4.2 123 22 136 305 0.4 0 1 0.3 02/13/2006 19:50:00 12.1 3.1 20.2 5.7 11.6 2.9 20.2 5.7 127 17 123 305 0.4 0 1 0.3 02/13/2006 20:00:00 13.7 3.1 22.6 6.8 13.3 3.1 21.4 7.2 132 15 133 305 0.4 0 1 0.3 02/13/2006 20:10:00 12.6 2.6 19.5 7.2 12.2 2.6 19.5 4.9 129 15 138 305 0.5 0 1 0.3 02/13/2006 20:20:00 13.9 2.5 21 8 13.6 2.5 22.1 8.8 129 15 131 305 0.5 0 1 0.3 02/13/2006 20:30:00 14.2 2.8 22.6 6.8 13.9 2.7 20.6 7.6 130 14 130 305 0.5 0 1 0.6 02/13/2006 20:40:00 13.4 2.3 21 7.6 13.1 2.3 21.8 8 128 17 140 305 0.5 0 1 0.6 02/13/2006 20:50:00 14.4 2.9 22.9 7.6 14 2.9 22.1 6.5 124 13 129 305 0.5 0 1 0.6 02/13/2006 21:00:00 13.9 3.1 21 6.5 13.4 3.2 22.6 5.7 126 16 139 305 0.5 0 1 0.3 02/13/2006 21:10:00 13.4 2.6 22.9 7.2 13 2.7 22.1 6.1 132 15 127 305 0.5 0 1 0.3 02/13/2006 21:20:00 13.6 2.9 22.6 5.3 13 3.1 22.1 3.8 131 15 137 305 0.5 0 1 0.3 02/13/2006 21:30:00 14.2 2.9 22.6 6.8 13.6 3.1 22.6 6.8 131 16 119 305 0.5 0 1 0.6 02/13/2006 21:40:00 13.2 3.1 21.4 7.2 12.6 2.8 21.4 5.7 130 17 121 305 0.5 0 1 0.3 02/13/2006 21:50:00 15 2.7 22.1 7.6 14.5 2.8 22.6 8 130 15 150 305 0.5 0 1 0.6 02/13/2006 22:00:00 14.5 2.8 20.6 6.1 14 2.9 21 6.1 127 17 108 305 0.5 0 1 0.6 02/13/2006 22:10:00 15.7 3.5 26 6.8 15.2 3.2 24 8 128 13 128 305 0.6 0.1 1.3 0.6 02/13/2006 22:20:00 15.9 3.1 25.2 8.4 15.4 3.1 25.2 7.6 129 13 100 305 0.8 0 1.3 0.6 02/13/2006 22:30:00 16.7 2.9 23.7 9.1 16.3 2.9 23.7 6.5 129 13 134 305 0.9 0 1.5 0.6 02/13/2006 22:40:00 17.6 3.3 26.3 10.7 17.3 3.3 25.6 8 133 13 144 305 1 0 1.5 0.8 02/13/2006 22:50:00 19.9 2.7 27.9 12.2 19.5 2.6 26.3 12.2 133 9 143 305 1.1 0.1 1.5 1 02/13/2006 23:00:00 19.7 2.8 26.8 11.8 19.4 2.7 26.3 11.8 131 9 134 305 1.1 0 1.5 1 02/13/2006 23:10:00 17.1 2.8 24 10.3 17.1 2.8 24 10.3 130 13 134 305 1.1 0.1 1.7 1 02/13/2006 23:20:00 16.5 2.6 23.3 9.9 16.4 2.7 25.2 10.7 131 12 135 305 1.1 0 1.3 1 02/13/2006 23:30:00 15.2 2.5 25.6 10.3 14.7 2.5 25.2 8.8 130 12 129 305 1 0 1.5 0.8 02/13/2006 23:40:00 14.6 2.7 22.9 8.4 14.3 2.7 22.9 8.4 129 14 118 305 1.1 0 1.5 1 02/13/2006 23:50:00 13.9 2.7 21.4 8 13.6 2.7 22.6 6.1 128 13 119 305 1.2 0 1.5 1 02/14/2006 00:00:00 13.1 2.6 19.5 6.5 12.9 2.4 19.9 5.7 130 14 134 305 1.4 0 2 1.3 02/14/2006 00:10:00 15.4 2.7 23.7 8.8 14.9 2.7 22.9 8 131 10 135 305 1.6 0 2.2 1.5 02/14/2006 00:20:00 16.6 2.6 22.6 7.2 16.2 2.5 22.1 9.1 135 11 120 305 1.6 0 2.2 1.5 02/14/2006 00:30:00 16 2.6 23.7 9.1 16.1 2.6 22.9 9.9 141 13 152 305 1.6 0 2.2 1.5 02/14/2006 00:40:00 17.1 3.3 25.6 9.1 17.1 2.9 24.4 10.7 147 13 143 305 1.7 0 2.2 1.5 02/14/2006 00:50:00 15.4 2.8 22.6 8 16.1 2.4 22.6 10.7 154 13 140 305 1.8 0 2.2 1.5 02/14/2006 01:00:00 15.7 2.6 24.4 9.1 16.7 2.5 24 9.9 155 11 150 305 1.7 0 2.2 1.5 02/14/2006 01:10:00 15.9 2.7 24 10.7 17.8 2.5 24.8 11.5 159 11 159 305 2 0 2.5 2 02/14/2006 01:20:00 15.7 2.8 22.9 9.9 16.9 2.3 23.7 11.1 156 12 144 305 2 0 2.5 2 02/14/2006 01:30:00 15.5 2.9 24 7.6 16.1 2.4 22.9 9.9 151 12 151 305 2.1 0 2.5 2 02/14/2006 01:40:00 15.7 3.3 23.7 8.4 15.7 2.8 22.6 9.9 149 12 154 305 2.1 0 2.5 2 02/14/2006 01:50:00 16.8 2.7 22.6 9.9 16.5 2.3 21.8 11.1 145 10 152 305 2.1 0 2.5 2 02/14/2006 02:00:00 14.9 2.8 21.4 8 14.7 2.4 21.4 9.5 147 12 140 305 2 0 2.5 2 02/14/2006 02:10:00 15.5 2.8 22.9 8.4 15.6 2.6 22.6 9.9 146 12 132 305 2 0 2.5 2 02/14/2006 02:20:00 15.2 3.1 22.6 8 15.1 2.7 22.9 8.4 147 11 154 305 2 0 2.5 2 02/14/2006 02:30:00 14.2 2.7 21.4 8 14.4 2.4 22.1 8.4 149 13 148 305 2 0 2.5 2 02/14/2006 02:40:00 14.4 2.9 22.9 6.8 15.1 2.5 23.3 9.5 153 12 150 305 2.1 0 2.5 2 02/14/2006 02:50:00 16.1 2.9 25.2 9.9 16.2 2.7 24.8 9.5 149 13 146 305 2.3 0.1 2.7 2.2 02/14/2006 03:00:00 16.4 2.9 22.1 7.6 16.4 2.7 22.9 8.8 145 11 156 305 2.1 0 2.5 2 02/14/2006 03:10:00 15.3 3.1 23.3 9.5 15.4 2.7 21.8 9.5 147 11 143 305 2 0 2.5 2 02/14/2006 03:20:00 16.5 3.1 23.7 9.1 16.1 2.7 22.6 9.5 146 10 140 305 2 0 2.5 2 02/14/2006 03:30:00 16.3 2.6 23.3 9.5 16.2 2.4 22.6 9.9 145 11 139 305 2 0 2.5 2 02/14/2006 03:40:00 15.8 3.3 25.2 9.5 16.1 2.8 24 9.9 150 12 154 305 2.1 0 2.7 2 02/14/2006 03:50:00 16.8 3.8 26.3 7.6 17.1 3.3 25.2 8 149 11 144 305 2.2 0.1 2.7 2.2 02/14/2006 04:00:00 16.2 2.7 23.7 7.6 16.4 2.3 22.9 9.5 148 13 145 305 2.1 0 2.7 2 02/14/2006 04:10:00 16.1 3.3 26.3 8.4 16 2.9 26 10.3 148 11 122 305 2.1 0 2.5 2 02/14/2006 04:20:00 14.8 3.1 22.9 8.4 15.1 2.7 21.8 9.1 149 12 144 305 1.9 0 2.5 2 02/14/2006 04:30:00 14.7 2.7 21.8 9.1 15.1 2.4 21.8 10.3 152 12 146 305 2 0 2.5 2 02/14/2006 04:40:00 13.8 2.7 21.8 8 14.7 2.4 22.1 9.5 156 13 147 305 2 0 2.5 2 02/14/2006 04:50:00 14.7 2.7 23.7 8.8 16.1 2.6 23.7 9.9 158 12 150 305 2.2 0 2.7 2 02/14/2006 05:00:00 14.2 2.7 22.9 9.1 15.5 2.4 24.8 9.9 156 12 139 305 2.1 0 2.5 2 02/14/2006 05:10:00 14.2 2.9 21.8 7.6 15.1 2.5 23.3 6.8 155 13 151 305 2.1 0 2.5 2 02/14/2006 05:20:00 14.5 2.9 24 8 14.9 2.4 22.9 9.1 153 13 145 305 2 0.1 2.5 2 02/14/2006 05:30:00 14.3 2.7 22.6 8.4 15.1 2.5 21.4 8.4 153 13 150 305 1.9 0.1 2.5 1.7 02/14/2006 05:40:00 14.4 3.1 22.6 7.2 15 2.5 21.4 9.9 152 12 145 305 1.9 0.2 2.5 1.7 02/14/2006 05:50:00 13.5 2.6 21.8 7.2 14.1 2.3 19.9 8 152 13 148 305 1.8 0.2 2.2 1.5 02/14/2006 06:00:00 15.4 3.1 23.7 8.8 16.2 2.7 22.9 10.3 153 12 133 305 1.9 0.1 2.5 1.5 02/14/2006 06:10:00 14.6 2.7 24.4 9.1 16.1 2.6 24.8 10.7 157 12 155 305 1.9 0.2 2.5 1.5 02/14/2006 06:20:00 15.1 2.7 24 8.8 16.1 2.5 23.3 11.1 156 12 147 305 1.8 0.2 2.5 1.5 02/14/2006 06:30:00 15.9 2.7 23.7 9.1 17.1 2.6 24.8 10.7 156 12 147 305 1.9 0.1 2.5 1.5 02/14/2006 06:40:00 14.8 3.1 24.8 9.5 15.5 2.8 22.9 8.8 153 13 139 305 1.8 0.2 2.2 1.5 02/14/2006 06:50:00 14.9 3.3 24.8 8 15.3 2.9 26.3 8 151 11 149 305 1.7 0.2 2.2 1.5 02/14/2006 07:00:00 14.7 3.2 23.7 8 15.3 2.5 23.3 8.8 153 11 145 305 1.7 0.2 2.2 1.5 02/14/2006 07:10:00 14.9 2.8 23.7 9.1 15.8 2.7 25.2 8.4 154 13 140 305 1.9 0.2 2.5 1.7 02/14/2006 07:20:00 14.4 2.9 22.6 7.2 15.3 2.6 21.4 8.8 155 12 144 305 1.7 0.2 2.2 1.5 02/14/2006 07:30:00 15.6 3.1 24.4 8.8 16.2 2.7 24 9.5 152 13 141 305 1.9 0.1 2.5 1.7 02/14/2006 07:40:00 15.4 2.7 24.8 9.5 16.6 2.5 23.7 11.5 156 13 165 305 2 0 2.5 2 02/14/2006 07:50:00 15.5 2.9 24.4 8.8 16.7 2.5 23.7 10.3 158 12 146 305 2 0 2.5 2 02/14/2006 08:00:00 14.7 2.6 23.3 8.4 15.9 2.5 23.3 9.5 156 13 137 305 2 0.1 2.5 2 02/14/2006 08:10:00 14.9 2.6 24.4 9.1 16.1 2.4 23.7 9.5 158 12 144 305 2 0.1 2.5 2 02/14/2006 08:20:00 15 2.5 23.7 9.5 16.4 2.5 23.7 10.7 157 12 138 305 2 0.1 2.5 2 02/14/2006 08:30:00 15.7 2.5 22.6 10.3 17.3 2.6 24 11.1 159 12 154 305 2.2 0.1 2.7 2 02/14/2006 08:40:00 15.4 2.8 24 8.4 16.4 2.5 22.9 11.1 156 13 138 305 2 0.2 2.5 2 02/14/2006 08:50:00 15 2.8 21.4 8 16 2.5 22.6 9.5 156 12 146 305 1.9 0.1 2.5 1.7 02/14/2006 09:00:00 15 2.7 24 8.4 16.1 2.5 23.7 10.3 156 13 145 305 1.9 0.1 2.5 1.7 02/14/2006 09:10:00 13.7 2.6 22.1 8 14.5 2.4 21.8 8.8 155 13 147 305 1.9 0.1 2.2 1.7 02/14/2006 09:20:00 14.2 2.6 22.6 9.1 15.3 2.5 22.6 9.9 156 13 156 305 1.9 0.1 2.5 1.7 02/14/2006 09:30:00 14.6 2.7 21.4 7.6 16 2.5 22.6 9.1 157 12 144 305 2 0.1 2.5 2 02/14/2006 09:40:00 14.9 2.7 23.7 9.5 16.9 2.5 22.9 11.5 160 11 147 305 2 0 2.5 2 02/14/2006 09:50:00 15.6 2.7 24.8 9.1 17.6 2.6 24.8 12.2 161 10 148 305 2 0 2.5 2 02/14/2006 10:00:00 15.3 2.7 23.3 9.9 17.2 2.5 24.8 9.9 162 10 169 305 2 0.1 2.5 2 02/14/2006 10:10:00 15.2 2.8 23.3 8.4 16.8 2.6 23.7 10.7 160 11 153 305 2 0.1 2.5 2 02/14/2006 10:20:00 14.1 2.5 21.8 7.6 15.2 2 21 9.1 157 12 146 305 1.7 0.2 2.2 1.5 02/14/2006 10:30:00 14.6 2.9 22.6 8 15.7 2.4 22.6 9.9 157 11 146 305 1.8 0.2 2.2 1.5 02/14/2006 10:40:00 14.4 2.6 24 8.8 15.7 2.4 24 10.7 159 13 147 305 1.7 0.1 2.2 1.5 02/14/2006 10:50:00 13.9 2.6 22.1 6.5 14.8 2.4 21.8 9.1 157 12 159 305 1.4 0.1 2 1.3 02/14/2006 11:00:00 13.4 2.3 21 8.4 14.9 2.2 20.6 10.3 161 10 151 305 1.2 0.1 1.5 1 02/14/2006 11:10:00 14.8 2.2 21.8 8.4 16.6 2.2 22.1 11.1 161 11 143 305 1.3 0.1 1.7 1 02/14/2006 11:20:00 14.2 2.4 20.2 7.6 15.7 2.4 21.8 9.9 160 11 155 305 1.4 0 1.7 1.3 02/14/2006 11:30:00 13.3 2.4 18.7 7.6 14.8 2.4 21 9.1 161 10 146 305 1.6 0 2 1.3 02/14/2006 11:40:00 13.1 2.2 19.1 8 14.9 2.2 20.6 9.1 163 10 140 305 1.4 0.1 2 1 02/14/2006 11:50:00 12.9 2 18.7 8 14.4 2 20.2 9.1 162 10 163 305 1 0 1.3 0.8 02/14/2006 12:00:00 12.9 2 18.7 8.4 14 2 19.5 9.1 159 10 151 305 1 0 1.5 1 02/14/2006 12:10:00 12.1 1.8 17.6 7.6 14.1 1.6 18.7 10.7 163 9 177 305 1 0 1.3 0.8 02/14/2006 12:20:00 11.9 1.9 16.8 6.8 13.6 1.6 18.3 9.5 162 9 163 305 0.8 0 1.3 0.6 02/14/2006 12:30:00 11.4 1.7 17.6 6.8 13.4 1.6 17.9 9.5 164 7 161 305 0.7 0.1 1.3 0.6 02/14/2006 12:40:00 11.6 1.7 15.6 7.6 13.6 1.7 17.9 9.9 165 8 153 305 0.8 0 1.3 0.6 02/14/2006 12:50:00 11.7 1.6 16.8 8.4 13.8 1.4 19.1 9.9 162 8 159 305 0.8 0 1.3 0.8 02/14/2006 13:00:00 11.3 1.5 15.6 7.6 13.8 1.5 18.3 9.1 165 7 166 305 0.8 0 1.3 0.6 02/14/2006 13:10:00 12.1 1.7 17.9 7.2 14.8 1.7 19.9 10.3 165 7 179 305 0.9 0 1.3 0.8 02/14/2006 13:20:00 11.9 1.6 17.6 8 15 1.6 19.5 11.1 165 6 163 305 1 0 1.3 1 02/14/2006 13:30:00 11.2 1.4 15.6 7.6 14.4 1.5 17.9 10.7 165 6 177 305 1 0 1.5 0.8 02/14/2006 13:40:00 12.7 1.9 16.8 8.4 14.4 1.5 17.9 10.7 175 10 175 305 0.6 0.4 1.5 -0.1 02/14/2006 13:50:00 12.8 1.9 16.4 7.6 12 2.2 16.4 6.8 211 16 205 305 -0.4 0.2 0.3 -0.6 02/14/2006 14:00:00 8.8 1 11.1 6.1 8 1.1 10.7 4.6 221 2 224 305 -0.6 0 0.1 -0.6 02/14/2006 14:10:00 9 1.1 12.2 6.5 8.3 1.2 11.8 5.7 219 3 219 305 -0.6 0 0.1 -0.8 02/14/2006 14:20:00 9.6 1.1 12.2 6.5 8.7 1.1 11.5 6.1 225 0 224 305 -1 0.1 -0.6 -1.1 02/14/2006 14:30:00 8 0.9 9.9 5.7 7.3 0.9 9.5 5.3 225 0 225 305 -1 0.1 -0.4 -1.1 02/14/2006 14:40:00 6.7 0.6 8 4.6 6.2 0.6 7.6 4.6 224 0 224 305 -1 0.1 -0.4 -1.1 02/14/2006 14:50:00 6 0.7 7.6 4.2 5.5 0.7 7.2 3.8 223 1 223 305 -1 0.1 -0.4 -1.1 02/14/2006 15:00:00 6.6 0.6 8.4 4.9 5.9 0.7 8 4.2 220 2 218 305 -0.9 0.1 -0.4 -1.1 02/14/2006 15:10:00 7.7 0.7 9.1 5.3 7 0.8 8.8 4.9 213 1 213 305 -0.8 0 -0.4 -1.1 02/14/2006 15:20:00 9.7 1.8 14.1 6.1 9.2 2 14.1 5.7 212 3 211 305 -0.7 0.1 -0.1 -1.1 02/14/2006 15:30:00 9.3 0.6 11.5 7.2 8.7 0.8 11.1 6.5 211 2 217 305 -0.6 0.1 0.1 -0.8 02/14/2006 15:40:00 9.4 0.6 10.3 6.1 8.5 0.8 10.3 6.1 209 3 211 305 -0.5 0.1 0.1 -0.6 02/14/2006 15:50:00 8.7 0.6 9.9 6.8 7.8 0.7 9.1 5.7 207 1 207 305 -0.5 0 0.1 -0.6 02/14/2006 16:00:00 9.1 0.4 10.7 8 8.5 0.4 9.9 6.8 206 0 206 305 -0.5 0 -0.1 -0.6 02/14/2006 16:10:00 10.3 1 12.2 7.2 9.5 1.1 11.8 6.5 206 0 206 305 -0.7 0 -0.1 -0.8 02/14/2006 16:20:00 11.1 0.5 12.6 8.8 10.5 0.6 12.2 8.4 206 0 206 305 -0.8 0.1 -0.4 -1.1 02/14/2006 16:30:00 10.8 0.6 12.2 9.1 10.2 0.8 12.2 7.6 206 0 207 305 -1 0.1 -0.4 -1.1 02/14/2006 16:40:00 10.2 0.8 12.2 7.6 9.4 1 11.5 6.5 207 0 207 305 -1.1 0 -0.6 -1.3 02/14/2006 16:50:00 9.8 0.8 11.8 7.2 8.8 0.9 11.1 6.5 207 0 207 305 -1.3 0.1 -0.6 -1.5 02/14/2006 17:00:00 10.1 0.5 11.8 8.8 9.6 0.6 11.5 7.6 207 0 208 305 -1.5 0.1 -0.8 -1.5 02/14/2006 17:10:00 10.4 0.5 11.8 9.1 10 0.5 11.1 8.4 207 0 208 305 -1.6 0.1 -1.1 -1.8 02/14/2006 17:20:00 10.7 0.6 12.2 9.5 10.2 0.7 11.5 7.6 207 0 208 305 -1.6 0 -1.1 -1.8 02/14/2006 17:30:00 10 0.5 11.1 8.8 9.6 0.6 10.7 7.6 207 0 208 305 -1.8 0 -1.3 -2 02/14/2006 17:40:00 9.3 0.5 10.7 7.2 9 0.6 10.3 6.8 207 0 208 305 -2 0.1 -1.5 -2.2 02/14/2006 17:50:00 9.1 0.5 10.3 8 8.8 0.5 10.3 7.2 207 0 207 305 -2 0.1 -1.8 -2.2 02/14/2006 18:00:00 8.5 0.8 10.3 6.1 8.3 0.8 10.3 5.7 208 0 208 305 -2.2 0.1 -1.8 -2.4 02/14/2006 18:10:00 8.7 0.4 9.5 8 8.8 0.3 9.9 8 207 0 208 305 -2.4 0.1 -1.8 -2.7 02/14/2006 18:20:00 8.9 0.3 9.5 8.4 9 0.4 9.9 7.2 206 0 207 305 -2.7 0.1 -2 -2.7 02/14/2006 18:30:00 9.3 0.4 10.3 8.4 9.5 0.4 10.3 8 205 0 207 305 -2.7 0 -2.2 -2.7 02/14/2006 18:40:00 9.3 0.2 9.9 8.8 9.7 0.2 10.3 9.1 194 6 203 305 -2.8 0 -2.4 -3.1 02/14/2006 18:50:00 9.5 0.2 9.9 9.1 10 0.3 10.7 9.1 188 1 189 305 -3 0 -2.7 -3.1 02/14/2006 19:00:00 9.5 0.5 10.3 6.1 9.9 0.4 10.7 8 185 1 186 305 -3 0 -2.7 -3.1 02/14/2006 19:10:00 9.3 0.7 10.3 6.1 9.6 0.6 10.7 7.6 183 0 184 305 -2.8 0 -2.4 -2.9 02/14/2006 19:20:00 9.2 0.8 10.7 6.1 9.6 0.6 11.1 7.6 183 0 183 305 -2.6 0.1 -2 -2.7 02/14/2006 19:30:00 9.6 0.8 11.1 6.5 10 0.6 11.1 8.4 183 1 182 305 -2.4 0 -2 -2.7 02/14/2006 19:40:00 10 1.2 11.5 5.3 10.4 1 11.8 7.6 181 2 183 305 -2.2 0 -1.8 -2.4 02/14/2006 19:50:00 11.2 0.4 12.2 8 11.5 0.4 12.2 10.3 184 2 181 305 -2.1 0.1 -1.8 -2.2 02/14/2006 20:00:00 10.4 0.9 11.8 7.2 11 0.7 12.2 9.1 182 0 182 305 -1.9 0 -1.3 -2 02/14/2006 20:10:00 10.2 0.6 11.5 7.6 10.5 0.5 11.5 8.4 183 0 182 305 -2.2 0 -2 -2.4 02/14/2006 20:20:00 7.4 1.4 10.3 3.8 8.7 1 10.7 5.3 170 10 155 305 -2.7 0.6 -2 -4 02/14/2006 20:30:00 7.3 1.3 9.9 4.2 8.4 0.6 10.7 6.1 161 7 155 305 -4.5 0.1 -3.8 -4.7 02/14/2006 20:40:00 5.9 1.1 9.5 3.4 8.2 1 9.9 5.3 168 7 157 305 -4.2 0.1 -4 -4.7 02/14/2006 20:50:00 7.4 1.2 9.9 4.6 8.5 0.8 10.3 6.5 178 5 181 305 -3.8 0.3 -3.1 -4.2 02/14/2006 21:00:00 7.4 1.3 9.5 3.8 8.9 0.8 10.7 6.8 178 4 180 305 -2.8 0.4 -1.8 -3.6 02/14/2006 21:10:00 6.1 1.2 9.1 3.8 8.8 0.5 10.3 7.2 174 4 175 305 -3.5 0 -2.7 -3.8 02/14/2006 21:20:00 8.1 1 9.9 5.3 8.8 0.6 10.7 6.8 182 4 182 305 -3 0.4 -2.4 -3.8 02/14/2006 21:30:00 7.7 1 9.9 4.2 8.5 0.7 10.3 6.5 180 4 183 305 -2.6 0.1 -2 -2.7 02/14/2006 21:40:00 5.4 1 8.8 3 7.4 0.8 9.9 4.9 172 7 184 305 -3.6 0.2 -2.7 -3.8 02/14/2006 21:50:00 6.6 1.2 8.4 3.4 7.5 0.5 9.1 6.1 180 6 185 305 -3.3 0 -2.9 -3.8 02/14/2006 22:00:00 8.2 0.4 9.9 6.1 8.4 0.4 9.5 6.8 186 2 192 305 -3 0 -2.4 -3.3 02/14/2006 22:10:00 7.3 0.6 8.8 4.9 7.7 0.5 8.8 6.5 183 3 186 305 -3 0 -2.4 -3.1 02/14/2006 22:20:00 6.9 0.6 8 3.8 7.3 0.5 8.4 6.1 182 3 183 305 -3 0.1 -2.4 -3.1 02/14/2006 22:30:00 6 1 7.6 3.4 6.5 0.6 8 4.9 181 5 184 305 -3.2 0 -3.1 -3.3 02/14/2006 22:40:00 4.2 1.1 7.6 2.3 6 0.5 7.6 4.9 173 6 189 305 -3.3 0.1 -3.1 -3.8 02/14/2006 22:50:00 3.9 0.9 6.1 2.3 5.4 0.5 6.5 3.8 174 6 183 305 -3.9 0.2 -3.3 -4.5 02/14/2006 23:00:00 3.6 0.8 5.7 1.9 4.6 0.6 6.5 3 177 6 183 305 -3.7 0.3 -3.3 -4.5 02/14/2006 23:10:00 2.7 0.6 4.6 1.5 3.8 0.5 4.9 2.3 173 6 179 305 -4.1 0.4 -3.6 -4.7 02/14/2006 23:20:00 2.6 0.6 4.6 1.1 3.9 0.4 4.9 2.6 174 7 186 305 -4.1 0.2 -3.8 -4.7 02/14/2006 23:30:00 3.1 0.9 4.6 1.1 4 0.4 4.9 3 151 18 138 305 -3.9 0 -3.6 -4.5 02/14/2006 23:40:00 7.5 1.4 9.1 3.8 7.4 1.3 9.5 4.2 123 7 120 305 -5 0.4 -4 -5.6 02/14/2006 23:50:00 8.4 0.5 9.5 6.8 8.2 0.6 9.5 6.8 126 3 126 305 -5.1 0 -4.7 -5.6 02/15/2006 00:00:00 7.6 0.4 9.1 6.5 7.5 0.4 8.4 6.5 130 4 125 305 -4.6 0.1 -4.5 -4.9 02/15/2006 00:10:00 6.9 0.4 8 5.7 6.7 0.4 7.6 5.7 127 5 131 305 -4.3 0.1 -4 -4.5 02/15/2006 00:20:00 6.7 0.4 8 5.7 6.6 0.5 7.6 5.3 125 5 122 305 -4 0 -3.8 -4.2 02/15/2006 00:30:00 6.8 0.3 7.6 5.7 7.1 0.4 8 6.1 120 3 119 305 -4.4 0 -4 -4.5 02/15/2006 00:40:00 5.5 0.4 6.8 4.9 5.9 0.4 6.8 4.9 118 5 118 305 -4.4 0 -4 -4.5 02/15/2006 00:50:00 5.6 0.7 8 4.9 5.6 0.6 8 4.6 108 7 120 305 -4.2 0.1 -4 -4.5 02/15/2006 01:00:00 6.8 0.5 8 5.3 7 0.4 8 5.7 124 3 127 305 -4.4 0 -4 -4.5 02/15/2006 01:10:00 6.2 0.4 7.2 5.3 6.3 0.4 7.6 5.3 119 5 127 305 -4.1 0.1 -3.8 -4.5 02/15/2006 01:20:00 6.2 0.4 7.2 4.9 6.1 0.4 7.2 4.9 113 3 113 305 -3.8 0 -3.3 -4 02/15/2006 01:30:00 6.7 0.4 8 5.7 6.6 0.4 7.6 5.7 117 3 117 305 -3.6 0 -3.3 -3.8 02/15/2006 01:40:00 7 0.7 8.8 4.9 6.9 0.6 8.4 5.3 116 5 115 305 -3.6 0.1 -3.1 -3.8 02/15/2006 01:50:00 6.8 0.4 7.6 5.7 6.5 0.4 7.2 5.3 108 4 108 305 -3.9 0 -3.8 -4 02/15/2006 02:00:00 6 0.4 6.8 4.9 5.6 0.4 6.8 4.9 103 3 105 305 -3.9 0 -3.3 -4 02/15/2006 02:10:00 6.3 0.4 7.2 5.3 5.9 0.4 6.8 4.9 101 4 96 305 -4 0 -3.8 -4.2 02/15/2006 02:20:00 6.9 0.6 8.4 4.9 6.4 0.6 8 4.9 99 4 99 305 -4.2 0.1 -3.8 -4.5 02/15/2006 02:30:00 7.1 0.5 8 5.3 6.7 0.5 7.6 5.3 100 4 102 305 -4.4 0 -4 -4.7 02/15/2006 02:40:00 5.4 0.8 7.2 4.2 5.1 0.7 6.8 3.8 87 8 95 305 -3.9 0 -3.8 -4 02/15/2006 02:50:00 4.6 0.3 4.9 3.8 4.5 0.3 5.3 3.8 63 6 65 305 -4.3 0.2 -3.8 -4.7 02/15/2006 03:00:00 5.1 0.3 5.7 4.2 5 0.3 5.7 3.8 65 7 73 305 -4.5 0.2 -3.8 -4.7 02/15/2006 03:10:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.8 64 3 57 305 -4.2 0 -3.8 -4.5 02/15/2006 03:20:00 4.7 0.3 5.3 4.2 4.7 0.3 5.3 4.2 54 6 46 305 -4.4 0 -3.8 -4.5 02/15/2006 03:30:00 4.6 0.2 4.9 4.2 4.5 0.2 4.9 4.2 57 2 57 305 -4.5 0 -4 -4.7 02/15/2006 03:40:00 5.3 0.3 6.1 4.6 5.1 0.3 5.7 4.6 55 3 51 305 -4.5 0 -3.8 -4.7 02/15/2006 03:50:00 5.4 0.2 6.1 4.9 5.3 0.2 5.7 4.9 53 5 50 305 -4.2 0 -3.6 -4.5 02/15/2006 04:00:00 5.2 0.3 6.1 4.6 5.2 0.3 5.7 4.6 48 3 52 305 -3.9 0 -3.8 -4 02/15/2006 04:10:00 6 0.5 7.2 4.9 5.8 0.5 7.2 4.6 53 4 62 305 -3.9 0 -3.8 -4 02/15/2006 04:20:00 6.7 0.5 8 5.3 6.6 0.5 7.6 5.3 60 4 54 305 -3.8 0 -3.6 -3.8 02/15/2006 04:30:00 7.3 0.3 8.4 6.5 7.2 0.3 8 6.5 66 2 67 305 -3.6 0 -3.3 -3.8 02/15/2006 04:40:00 7.2 0.4 8 6.1 7 0.4 8 6.1 62 3 66 305 -3.5 0 -3.3 -3.8 02/15/2006 04:50:00 6.7 0.5 8 5.3 6.6 0.4 8 5.3 58 3 57 305 -3.5 0 -3.3 -3.8 02/15/2006 05:00:00 6.5 0.4 7.6 5.7 6.4 0.4 7.6 5.3 58 4 56 305 -3.3 0 -2.7 -3.6 02/15/2006 05:10:00 6.9 0.6 8.8 5.7 6.8 0.5 8.8 5.7 60 3 66 305 -3.3 0 -2.7 -3.3 02/15/2006 05:20:00 7.5 0.5 8.8 6.5 7.4 0.4 8.4 6.1 60 4 67 305 -3.2 0 -2.7 -3.3 02/15/2006 05:30:00 7.6 0.5 9.1 6.5 7.5 0.5 9.1 6.5 61 3 63 305 -3.2 0.1 -2.7 -3.3 02/15/2006 05:40:00 8.7 0.5 9.9 7.6 8.5 0.5 9.5 7.2 69 3 70 305 -2.9 0.1 -2.2 -3.1 02/15/2006 05:50:00 8.5 0.5 9.5 6.8 8.3 0.5 9.5 6.8 70 2 68 305 -2.7 0 -2.2 -2.9 02/15/2006 06:00:00 7.7 0.5 8.8 6.5 7.5 0.5 8.8 6.1 69 4 65 305 -2.7 0 -2.2 -2.7 02/15/2006 06:10:00 7.8 0.4 8.8 6.8 7.6 0.4 8.4 6.5 68 3 71 305 -2.7 0 -2.2 -2.7 02/15/2006 06:20:00 7.2 0.4 8.4 5.7 7.1 0.4 8.4 5.7 69 2 71 305 -2.6 0.1 -2 -2.7 02/15/2006 06:30:00 6.9 0.4 7.6 5.7 6.7 0.5 7.6 5.3 67 2 69 305 -2.6 0.1 -2 -2.7 02/15/2006 06:40:00 7.2 0.4 8 6.1 6.9 0.4 8 5.3 68 3 70 305 -2.5 0 -2 -2.7 02/15/2006 06:50:00 7.3 0.4 8.8 6.1 7 0.4 8.4 5.7 70 3 73 305 -2.3 0 -1.8 -2.7 02/15/2006 07:00:00 7.1 0.4 8.4 6.1 7 0.4 8 6.1 71 3 78 305 -2.2 0 -1.8 -2.4 02/15/2006 07:10:00 7 0.5 8 5.3 6.9 0.5 8 5.7 72 4 66 305 -2 0 -1.8 -2.2 02/15/2006 07:20:00 6.3 0.8 8.8 4.2 6.2 0.7 8.4 4.2 72 9 80 305 -1.9 0 -1.8 -2 02/15/2006 07:30:00 6 1.1 8.8 3.4 6 1 8.8 3.4 72 12 71 305 -1.7 0 -1.3 -2 02/15/2006 07:40:00 6.3 1 9.1 3.4 6.2 1 9.1 3.4 79 12 85 305 -1.6 0 -1.1 -1.8 02/15/2006 07:50:00 4.9 1.3 9.1 1.9 4.9 1.4 9.1 1.1 78 18 78 305 -1.6 0 -1.1 -1.8 02/15/2006 08:00:00 4.7 1.2 8.4 1.9 4.4 1.2 8 1.9 94 22 65 305 -1.6 0 -1.3 -1.8 02/15/2006 08:10:00 5.3 1.1 9.9 3 5 1.2 10.7 1.9 106 15 123 305 -1.5 0 -0.8 -1.8 02/15/2006 08:20:00 5.8 1 8.4 2.6 5.6 0.9 8 3.4 106 15 119 305 -1.3 0 -0.8 -1.3 02/15/2006 08:30:00 5.6 1 8.8 3 5.4 1.1 8.8 3 104 17 123 305 -1.2 0 -0.6 -1.3 02/15/2006 08:40:00 5.7 1.2 9.1 3 5.6 1.3 9.5 3 106 15 120 305 -1.2 0 -0.6 -1.3 02/15/2006 08:50:00 5.7 1.3 9.5 2.3 5.5 1.3 9.1 2.3 96 15 89 305 -1.2 0 -0.6 -1.3 02/15/2006 09:00:00 5.7 1.2 9.5 3.4 5.5 1.1 9.1 3 105 12 102 305 -1.4 0 -0.8 -1.5 02/15/2006 09:10:00 5.3 1 7.6 3.4 5.1 1 8 3.4 95 16 89 305 -1.5 0 -1.1 -1.5 02/15/2006 09:20:00 4.6 1.1 7.6 1.9 4.7 1.1 7.2 2.3 95 17 87 305 -1.5 0.1 -1.1 -1.8 02/15/2006 09:30:00 3.8 0.9 6.8 2.3 3.8 0.8 6.8 1.5 97 22 102 305 -1.3 0 -0.6 -1.3 02/15/2006 09:40:00 3.9 1.1 6.1 0.7 3.7 0.9 6.1 1.9 98 17 77 305 -1.4 0 -1.1 -1.8 02/15/2006 09:50:00 4.2 0.9 6.5 1.9 4.2 0.8 6.1 1.5 89 18 85 305 -1.3 0 -0.6 -1.5 02/15/2006 10:00:00 4.6 1 7.2 1.5 4.4 0.9 6.8 2.3 94 22 92 305 -1.4 0 -0.8 -1.5 02/15/2006 10:10:00 4.3 1.2 7.2 1.1 4.2 1.2 7.6 1.5 109 17 108 305 -1.3 0 -0.6 -1.5 02/15/2006 10:20:00 4.6 0.9 7.2 1.9 4.5 0.8 6.8 2.3 104 16 102 305 -1.1 0 -0.6 -1.3 02/15/2006 10:30:00 4 1.1 6.8 1.5 4 1.1 7.2 1.9 116 17 112 305 -1.1 0.1 -0.6 -1.1 02/15/2006 10:40:00 5 1.1 8.4 2.3 5.1 1.1 7.6 2.6 117 15 123 305 -1 0.1 -0.6 -1.1 02/15/2006 10:50:00 6.4 1.3 9.5 3 6.6 1.3 9.9 3.4 131 14 137 305 -1 0.1 -0.4 -1.1 02/15/2006 11:00:00 7.4 1.8 11.1 3.8 7.3 1.8 10.7 3.8 135 11 135 305 -1 0.1 -0.4 -1.1 02/15/2006 11:10:00 7.1 1.1 9.5 3.4 7 1 9.5 4.6 140 10 144 305 -1.1 0 -0.6 -1.3 02/15/2006 11:20:00 7.8 0.7 9.5 4.9 7.6 0.7 9.1 5.3 134 6 136 305 -1.1 0 -0.6 -1.3 02/15/2006 11:30:00 7.8 0.8 9.5 4.9 7.6 0.8 9.5 5.7 132 7 127 305 -1.1 0 -0.6 -1.3 02/15/2006 11:40:00 7.3 1.1 10.3 4.2 7.3 1.1 10.7 5.3 138 9 131 305 -1.2 0 -0.6 -1.3 02/15/2006 11:50:00 7.7 1.1 10.7 4.6 7.7 1 11.1 5.3 145 9 145 305 -1.3 0 -0.6 -1.3 02/15/2006 12:00:00 7.6 1.1 11.1 4.6 7.6 1 11.1 5.3 143 11 145 305 -1.3 0 -0.8 -1.3 02/15/2006 12:10:00 8 1 11.5 5.3 8 1 10.7 5.3 142 9 150 305 -1.4 0 -0.8 -1.5 02/15/2006 12:20:00 7.8 1.3 11.8 4.2 7.8 1.2 11.8 5.3 142 11 142 305 -1.3 0 -0.6 -1.3 02/15/2006 12:30:00 6.6 1 9.5 3.4 6.8 1 10.3 4.2 146 13 129 305 -1.2 0 -0.6 -1.3 02/15/2006 12:40:00 6.5 1.9 11.8 3 6.8 1.6 11.8 3.4 150 13 130 305 -1.3 0 -0.6 -1.3 02/15/2006 12:50:00 8.2 1.8 13.3 4.2 8.9 1.2 12.6 6.1 156 9 153 305 -1.6 0.1 -1.1 -1.8 02/15/2006 13:00:00 7.6 1.2 11.8 5.3 10.5 1.3 13.3 7.2 163 6 159 305 -1.8 0 -1.3 -2 02/15/2006 13:10:00 8.1 1.4 12.6 4.9 10.9 0.8 13 8.8 161 5 156 305 -1.9 0 -1.3 -2 02/15/2006 13:20:00 7.7 1.3 11.5 5.3 10.4 0.8 12.2 7.6 161 4 157 305 -1.8 0 -1.3 -2 02/15/2006 13:30:00 7 1.3 10.3 4.2 9 1 11.8 6.1 162 7 156 305 -1.8 0 -1.3 -2 02/15/2006 13:40:00 6.7 1.4 11.1 3.4 7.6 1 10.7 4.9 156 10 155 305 -1.6 0 -1.1 -1.8 02/15/2006 13:50:00 7.2 1.4 10.7 3.8 7.5 1.1 10.3 4.9 152 10 156 305 -1.6 0 -1.1 -1.8 02/15/2006 14:00:00 6.8 1.2 10.7 4.2 8.9 1 11.5 5.3 160 6 156 305 -1.9 0 -1.3 -2 02/15/2006 14:10:00 6.8 1.2 11.1 4.6 9.2 1.2 13.3 6.8 165 6 158 305 -1.8 0.1 -1.1 -2 02/15/2006 14:20:00 7.9 1.5 12.6 4.6 10.3 1.4 13.7 7.2 169 7 179 305 -1.9 0.2 -1.3 -2.4 02/15/2006 14:30:00 8.5 1.3 12.2 5.3 10.7 1 13.3 7.6 174 6 179 305 -2.4 0 -2 -2.7 02/15/2006 14:40:00 8.4 1.3 11.8 4.9 10.4 0.9 12.6 8 176 6 188 305 -2.3 0 -1.8 -2.4 02/15/2006 14:50:00 10 1.8 13.3 6.1 12 1.2 14.5 9.1 176 5 176 305 -2.4 0 -1.8 -2.7 02/15/2006 15:00:00 9.6 0.9 11.8 6.5 10 0.9 12.6 8 182 4 169 305 -2.5 0 -2 -2.7 02/15/2006 15:10:00 9.3 1.6 14.1 5.7 11 1.2 13.7 8 176 6 184 305 -2.5 0 -2 -2.7 02/15/2006 15:20:00 9.9 1.2 13.7 6.5 10.8 1.2 13.7 8 180 5 181 305 -2.5 0 -2 -2.7 02/15/2006 15:30:00 10.2 1.1 13.3 7.2 10.4 1 12.6 7.6 183 4 186 305 -2.5 0.1 -2 -2.7 02/15/2006 15:40:00 10 1.4 13.7 5.7 10.5 1 13.7 7.2 181 5 182 305 -3.1 0.2 -2.7 -3.6 02/15/2006 15:50:00 9.4 1.3 11.8 5.3 9.4 1.1 12.2 6.5 183 4 182 305 -3.6 0.1 -3.3 -3.8 02/15/2006 16:00:00 8.7 1.1 11.5 5.7 8.6 0.9 11.5 6.1 184 4 182 305 -3.7 0.1 -3.1 -3.8 02/15/2006 16:10:00 10.1 0.8 12.2 7.2 10.3 0.8 12.2 8 183 4 183 305 -3.6 0 -3.1 -3.8 02/15/2006 16:20:00 7.8 1.2 9.9 4.6 8.4 0.9 10.7 6.5 180 6 181 305 -3.6 0.1 -3.1 -3.8 02/15/2006 16:30:00 8.7 1.5 12.6 4.9 9.4 0.9 11.8 7.2 158 8 141 305 -3.1 0.1 -2.7 -3.3 02/15/2006 16:40:00 11.1 1 13.3 8.4 10.4 0.9 12.6 7.6 151 4 150 305 -3.3 0 -3.1 -3.3 02/15/2006 16:50:00 9 2.5 14.5 4.6 10.2 1.2 12.6 7.2 159 6 154 305 -3.3 0 -3.1 -3.6 02/15/2006 17:00:00 7.5 1.2 11.8 4.9 10.2 1.1 12.6 7.2 163 4 158 305 -3.6 0 -3.1 -3.8 02/15/2006 17:10:00 8.4 1.1 11.5 5.7 11.3 0.8 13.7 8 163 4 163 305 -3.6 0 -3.1 -3.8 02/15/2006 17:20:00 11.9 1.9 15.3 6.5 11.8 1 14.5 8.8 152 7 154 305 -3.7 0.1 -3.1 -4 02/15/2006 17:30:00 13.6 1.2 16.1 9.1 13 1.1 15.3 9.9 150 5 150 305 -4 0 -3.8 -4.2 02/15/2006 17:40:00 12.4 1.5 15.6 8.4 11.8 1.3 14.9 8.4 150 5 150 305 -4.1 0 -3.8 -4.5 02/15/2006 17:50:00 10.4 0.9 13.3 8 9.9 0.8 12.6 8 144 6 146 305 -4.6 0.1 -4.2 -4.9 02/15/2006 18:00:00 11 0.6 13 9.5 10.6 0.6 12.2 9.1 140 3 138 305 -4.7 0 -4.2 -4.9 02/15/2006 18:10:00 11.4 0.7 13 9.5 11 0.7 12.6 9.1 134 4 131 305 -4.5 0 -4.5 -4.7 02/15/2006 18:20:00 12.5 0.9 14.5 9.5 12.2 0.8 14.1 9.9 130 4 131 305 -4.4 0 -4.5 -4.7 02/15/2006 18:30:00 12.5 1 16.1 9.9 12.1 1 15.6 9.1 130 4 138 305 -4.3 0 -4 -4.5 02/15/2006 18:40:00 12.6 1.1 15.6 9.1 12.4 1.1 14.9 9.5 129 6 135 305 -4.1 0 -3.8 -4.2 02/15/2006 18:50:00 13.3 1 15.6 9.5 12.8 1 15.3 9.1 129 4 133 305 -4 0 -3.8 -4 02/15/2006 19:00:00 13 1.5 15.6 9.1 12.7 1.3 15.3 8.4 127 6 127 305 -3.9 0 -3.3 -4 02/15/2006 19:10:00 13.1 1.1 16.1 9.9 12.6 1 16.1 9.1 127 5 133 305 -3.9 0 -3.3 -4 02/15/2006 19:20:00 11.8 1.5 16.4 7.6 11.5 1.5 16.1 7.6 122 9 130 305 -3.7 0.1 -3.3 -3.8 02/15/2006 19:30:00 11.2 1.4 14.9 7.2 10.9 1.4 15.3 7.2 124 11 126 305 -3.7 0.1 -3.1 -3.8 02/15/2006 19:40:00 11.3 1.7 15.6 8 11 1.7 14.9 7.6 127 11 139 305 -3.7 0 -3.3 -3.8 02/15/2006 19:50:00 11.3 1.7 15.6 6.1 11.1 1.7 15.6 6.8 127 10 137 305 -3.6 0 -3.1 -3.8 02/15/2006 20:00:00 10.3 1.5 14.9 6.5 10 1.5 14.9 6.5 117 10 124 305 -3.4 0 -2.9 -3.6 02/15/2006 20:10:00 9.2 1.6 13.7 5.7 9 1.5 13 4.9 123 13 112 305 -3.3 0 -3.3 -3.3 02/15/2006 20:20:00 9.6 1 12.2 6.8 9.3 0.9 11.8 6.8 134 7 134 305 -3.3 0 -2.7 -3.3 02/15/2006 20:30:00 8.7 1.5 13 3.8 8.5 1.3 12.2 5.3 139 11 130 305 -3 0 -2.7 -3.3 02/15/2006 20:40:00 9.8 1.6 14.1 6.1 9.6 1.5 14.1 6.1 140 10 141 305 -2.7 0.1 -2.4 -2.9 02/15/2006 20:50:00 9.3 1.5 12.6 5.3 9.4 1.3 12.6 6.1 140 10 127 305 -2.4 0 -2.2 -2.4 02/15/2006 21:00:00 8.1 1.5 11.8 4.9 8.1 1.3 11.1 4.6 146 11 149 305 -2.1 0.1 -1.8 -2.4 02/15/2006 21:10:00 8.8 1.5 12.2 4.6 8.9 1.3 12.2 5.3 148 10 149 305 -1.7 0 -1.3 -2 02/15/2006 21:20:00 10.1 1.5 14.1 5.7 9.8 1.3 13.3 7.2 148 8 146 305 -1.6 0 -1.1 -1.8 02/15/2006 21:30:00 9.5 1.6 12.2 5.3 9.4 1.3 12.6 5.7 148 10 146 305 -1.4 0 -0.8 -1.5 02/15/2006 21:40:00 7.9 1.6 11.8 2.6 8 1.3 11.5 4.6 148 11 147 305 -1.3 0 -0.8 -1.3 02/15/2006 21:50:00 9.1 1.3 12.6 5.7 8.9 1.2 11.5 5.7 147 9 149 305 -1.2 0 -0.6 -1.3 02/15/2006 22:00:00 9.5 1.6 14.1 4.9 9.4 1.4 13.3 6.1 145 10 149 305 -1.1 0 -0.6 -1.3 02/15/2006 22:10:00 10.5 1.5 15.3 6.5 10.3 1.4 14.1 6.8 145 10 120 305 -1.1 0 -1.1 -1.1 02/15/2006 22:20:00 10.4 1.3 13.7 6.8 10.3 1.3 14.5 7.6 143 9 145 305 -1 0.1 -0.4 -1.1 02/15/2006 22:30:00 10.9 1.5 14.5 6.8 10.6 1.3 14.1 6.8 143 9 140 305 -1 0.1 -0.4 -1.1 02/15/2006 22:40:00 10.4 1.4 14.9 7.2 10.2 1.2 14.5 7.2 137 8 136 305 -1 0.1 -0.4 -1.1 02/15/2006 22:50:00 10.6 1 13.7 8.4 10.3 1 13 7.6 132 5 130 305 -1 0.1 -0.6 -1.1 02/15/2006 23:00:00 10 0.9 11.8 7.2 9.8 0.8 11.8 7.6 130 6 132 305 -1.1 0 -0.6 -1.1 02/15/2006 23:10:00 8.8 1 11.5 6.1 8.5 0.9 10.7 6.5 131 7 145 305 -1.1 0 -0.6 -1.1 02/15/2006 23:20:00 10.3 1 13 7.6 9.9 1 13 7.2 134 6 134 305 -1.1 0 -0.6 -1.1 02/15/2006 23:30:00 10.6 1 13.3 7.6 10.2 1 12.6 6.8 134 6 133 305 -1 0.1 -0.6 -1.1 02/15/2006 23:40:00 11.6 1 14.1 8.8 11.3 1 14.1 8.8 133 6 137 305 -1 0.1 -0.4 -1.1 02/15/2006 23:50:00 11.8 1.5 15.6 7.6 11.5 1.4 14.5 7.6 132 8 134 305 -0.9 0 -0.4 -1.1 02/16/2006 00:00:00 9 1.6 13.7 5.3 8.8 1.6 13 5.3 126 13 118 305 -1 0.1 -0.4 -1.1 02/16/2006 00:10:00 10 1.7 15.6 6.1 9.8 1.6 14.1 4.9 130 13 148 305 -1.1 0 -0.6 -1.1 02/16/2006 00:20:00 11.1 2.1 18.3 5.3 10.9 1.9 16.1 4.2 131 12 146 305 -1.1 0 -0.6 -1.3 02/16/2006 00:30:00 11 2.1 17.2 4.6 10.6 2.2 16.1 4.2 127 13 127 305 -1.1 0 -0.6 -1.3 02/16/2006 00:40:00 9.7 2.1 15.6 5.3 9.2 2 14.9 4.6 125 15 126 305 -1.1 0 -0.6 -1.3 02/16/2006 00:50:00 9.1 2.2 16.4 4.6 8.9 2.2 16.1 4.9 124 14 151 305 -1.2 0 -0.6 -1.3 02/16/2006 01:00:00 9.4 1.7 14.1 4.9 9.1 1.8 14.1 4.9 122 13 124 305 -1.4 0 -0.8 -1.5 02/16/2006 01:10:00 9.4 1.7 14.9 5.7 9.2 1.7 14.9 5.7 126 15 117 305 -1.3 0 -1.1 -1.3 02/16/2006 01:20:00 10.4 2.1 16.1 6.1 10.1 2.1 14.9 5.3 134 12 145 305 -1.2 0 -0.6 -1.3 02/16/2006 01:30:00 13.1 1.4 16.1 9.5 12.7 1.5 16.4 8 133 8 129 305 -1.1 0 -0.6 -1.3 02/16/2006 01:40:00 11.7 2.2 16.1 6.1 11.6 1.9 15.6 6.8 137 9 137 305 -1.1 0 -0.6 -1.3 02/16/2006 01:50:00 11.1 2 15.6 6.5 10.9 1.9 15.6 6.5 147 11 139 305 -1.2 0 -0.6 -1.5 02/16/2006 02:00:00 10.7 2 15.3 6.1 12.2 1.7 17.2 7.2 160 10 136 305 -1.8 0.1 -1.1 -2 02/16/2006 02:10:00 10.3 1.4 15.3 7.2 14.5 1.2 17.6 11.5 164 5 155 305 -2.1 0 -2 -2.2 02/16/2006 02:20:00 11.2 1.6 16.1 7.6 14.3 1.5 18.7 9.9 168 6 152 305 -2.2 0 -1.8 -2.7 02/16/2006 02:30:00 10.8 1.6 15.6 7.2 12.8 1.4 17.2 9.1 174 6 176 305 -2.5 0 -2 -2.7 02/16/2006 02:40:00 11.9 1.7 15.3 6.5 13.1 1 15.6 10.3 180 6 182 305 -2.4 0 -1.8 -2.7 02/16/2006 02:50:00 16.4 2.4 21.4 11.8 15.7 2.3 20.6 10.7 198 9 201 305 -2.3 0 -1.8 -2.7 02/16/2006 03:00:00 21.7 3.3 29.1 12.6 20 3.2 26.8 12.6 210 6 210 305 -2.4 0 -2 -2.7 02/16/2006 03:10:00 21.2 2.8 28.7 15.6 19.4 2.8 26 13 222 5 222 305 -2.6 0 -2 -2.7 02/16/2006 03:20:00 19.3 2 24 12.2 17.7 2.1 23.3 12.6 219 6 225 305 -2.7 0 -2 -2.9 02/16/2006 03:30:00 16.8 2.3 22.6 12.2 15.3 2.3 21 10.7 223 6 227 305 -2.8 0 -2.4 -3.1 02/16/2006 03:40:00 15.9 1.5 19.1 11.8 14.8 1.5 17.9 11.1 215 5 217 305 -2.7 0 -2.2 -2.7 02/16/2006 03:50:00 15.9 1.8 20.2 10.7 14.5 1.9 19.5 9.9 209 5 209 305 -2.6 0 -2.4 -2.7 02/16/2006 04:00:00 16.8 1.6 20.2 11.1 15.4 1.7 19.1 9.5 206 5 203 305 -2.7 0.1 -2.2 -2.9 02/16/2006 04:10:00 17 1 19.9 13.3 15.9 1.2 19.9 12.6 205 4 207 305 -3 0.1 -2.7 -3.3 02/16/2006 04:20:00 17.6 1.1 20.6 14.5 16.4 1.3 19.5 12.2 205 4 206 305 -3.2 0.1 -2.7 -3.3 02/16/2006 04:30:00 17.2 1.1 20.2 13.7 16.2 1.2 19.5 11.5 203 4 203 305 -3.3 0 -2.7 -3.6 02/16/2006 04:40:00 17 1 19.5 14.5 16.2 1.1 18.7 13 201 3 197 305 -3.5 0 -3.1 -3.6 02/16/2006 04:50:00 16.4 1.1 19.5 13.7 15.5 1.1 17.9 12.6 201 3 204 305 -3.6 0 -3.1 -3.8 02/16/2006 05:00:00 15.4 1.1 18.3 12.6 14.4 1.2 17.9 11.5 199 3 200 305 -3.6 0 -3.3 -3.8 02/16/2006 05:10:00 13 1.4 16.8 10.3 12.3 1.4 15.3 9.1 193 5 201 305 -4 0.3 -3.1 -4.7 02/16/2006 05:20:00 12.3 0.8 14.9 10.3 11.4 0.9 13.7 8.4 191 3 194 305 -4.6 0 -4.2 -4.7 02/16/2006 05:30:00 12.9 0.8 14.5 10.7 12 1 14.1 9.1 194 4 203 305 -4.2 0.1 -3.8 -4.7 02/16/2006 05:40:00 12.7 0.7 14.5 10.7 11.7 0.9 13.7 9.1 194 4 194 305 -4.1 0.2 -3.6 -4.5 02/16/2006 05:50:00 12.9 1.1 15.3 10.3 12 1.2 14.5 7.6 194 4 195 305 -4.1 0 -3.6 -4.2 02/16/2006 06:00:00 12 0.8 14.1 9.5 11.1 0.9 13 7.2 191 4 202 305 -4.6 0.2 -4.2 -4.9 02/16/2006 06:10:00 11.9 0.8 14.1 9.5 11.1 0.9 13.7 8.8 190 4 189 305 -4.9 0 -4.7 -5.1 02/16/2006 06:20:00 12 0.7 14.5 9.5 11.5 0.8 13.3 9.5 188 3 190 305 -5.1 0 -4.9 -5.1 02/16/2006 06:30:00 13.2 0.8 16.4 10.7 12.5 1 15.3 9.1 189 3 187 305 -5 0 -4.7 -5.1 02/16/2006 06:40:00 13.7 1 16.4 10.3 12.5 1 15.6 9.5 191 4 193 305 -4.4 0.2 -4 -4.9 02/16/2006 06:50:00 13.4 1.1 17.6 10.3 12.3 1.2 15.6 9.1 191 4 195 305 -4.2 0.1 -3.8 -4.5 02/16/2006 07:00:00 12.6 1.1 15.3 9.5 11.6 1.2 15.3 8 191 4 197 305 -4.1 0.1 -3.8 -4.5 02/16/2006 07:10:00 12 1 14.5 9.5 11.3 1 13.7 8.4 189 4 196 305 -4.2 0.1 -3.8 -4.5 02/16/2006 07:20:00 13.1 0.7 15.3 11.1 12.4 0.9 14.5 8.8 188 3 188 305 -3.9 0 -3.8 -4 02/16/2006 07:30:00 12.8 0.9 15.6 9.9 12.1 0.9 14.1 8.4 188 4 197 305 -3.9 0 -3.8 -4 02/16/2006 07:40:00 13.5 1 16.8 10.7 12.4 1.2 15.6 9.1 192 4 199 305 -3.6 0.1 -3.3 -4 02/16/2006 07:50:00 13.9 1 16.4 10.7 12.9 1.1 16.1 9.5 192 4 193 305 -3.3 0 -3.1 -3.3 02/16/2006 08:00:00 14.6 0.9 16.8 11.8 13.6 1.1 16.1 9.9 192 4 186 305 -3.3 0 -2.7 -3.6 02/16/2006 08:10:00 13.5 1.1 16.1 10.7 12.5 1.2 15.6 9.5 192 5 193 305 -3.4 0 -2.7 -3.8 02/16/2006 08:20:00 13.4 1.1 17.2 9.9 12.6 1.2 15.6 9.1 190 4 192 305 -3.5 0 -3.1 -3.8 02/16/2006 08:30:00 13.3 1.1 16.1 10.3 12.5 1.2 16.4 9.1 191 4 197 305 -3.6 0.1 -3.1 -3.8 02/16/2006 08:40:00 12.7 0.9 15.3 10.3 11.9 1 14.5 9.1 190 4 198 305 -3.9 0 -3.3 -4 02/16/2006 08:50:00 14.3 1.9 18.3 9.5 13.3 1.8 17.9 9.5 194 5 200 305 -3.3 0.1 -2.7 -3.8 02/16/2006 09:00:00 13.2 0.9 15.6 9.9 12.5 1 14.9 9.5 188 3 189 305 -3.7 0.1 -2.9 -4 02/16/2006 09:10:00 13.1 1.1 16.1 10.3 12.4 1 15.3 9.5 188 4 192 305 -4.2 0.1 -3.8 -4.5 02/16/2006 09:20:00 13.3 0.9 15.6 10.3 12.5 1 14.9 9.1 188 3 187 305 -4.4 0 -4.2 -4.7 02/16/2006 09:30:00 12.8 0.8 15.3 10.7 11.9 0.9 14.5 9.1 190 4 194 305 -4.4 0 -3.8 -4.5 02/16/2006 09:40:00 13.1 0.8 16.4 10.3 12.5 0.9 15.3 9.1 189 3 194 305 -4.2 0 -3.8 -4.5 02/16/2006 09:50:00 13.7 1 16.4 11.5 12.9 1.1 16.4 9.9 190 4 186 305 -4 0 -3.3 -4.2 02/16/2006 10:00:00 13.5 1.2 16.8 11.1 12.7 1.2 16.8 9.5 190 5 190 305 -3.9 0 -3.3 -4 02/16/2006 10:10:00 12.6 1 15.3 10.3 12.4 0.9 14.9 10.3 187 4 185 305 -4.1 0.1 -3.6 -4.5 02/16/2006 10:20:00 12.4 0.8 15.3 10.3 12 0.9 14.9 9.1 187 3 188 305 -4.4 0 -3.8 -4.7 02/16/2006 10:30:00 12.2 0.8 14.1 9.9 11.6 0.8 13.7 9.1 189 4 192 305 -4.5 0 -4 -4.7 02/16/2006 10:40:00 11.6 1 14.1 9.5 10.9 1 13.7 8.4 192 5 194 305 -4.5 0.1 -3.8 -4.7 02/16/2006 10:50:00 11.4 0.8 13.3 9.1 11 0.7 13 8 188 3 197 305 -4.9 0.1 -4.5 -5.1 02/16/2006 11:00:00 10.4 0.6 12.2 8.8 10 0.6 11.8 7.6 187 3 188 305 -5.2 0.1 -5.1 -5.6 02/16/2006 11:10:00 10.5 0.5 11.5 8.8 10.3 0.6 11.5 8.4 186 3 189 305 -5.3 0 -5.1 -5.6 02/16/2006 11:20:00 10.4 0.5 11.5 8.8 10.5 0.5 11.8 8.8 185 3 184 305 -5.3 0 -5.1 -5.6 02/16/2006 11:30:00 10.7 0.5 11.8 8 10.7 0.5 11.8 9.1 185 3 183 305 -5.3 0 -5.1 -5.6 02/16/2006 11:40:00 10.1 0.4 11.1 9.1 10 0.6 11.5 8.4 186 3 185 305 -5.5 0 -5.3 -5.6 02/16/2006 11:50:00 9.8 0.5 11.1 8 9.6 0.7 11.1 6.5 186 3 192 305 -5.3 0.1 -5.1 -5.6 02/16/2006 12:00:00 9.3 0.6 10.7 6.8 9.2 0.7 10.7 6.8 186 3 186 305 -5.2 0 -5.1 -5.3 02/16/2006 12:10:00 8.3 0.7 10.7 6.5 8 0.7 9.9 6.1 187 4 197 305 -5.1 0.1 -4.7 -5.3 02/16/2006 12:20:00 9.7 0.5 11.1 7.6 9.9 0.5 11.1 8 185 2 187 305 -4.9 0 -4.7 -5.1 02/16/2006 12:30:00 9.2 0.4 10.3 8 9.2 0.4 10.3 7.6 186 2 185 305 -4.9 0 -4.7 -5.1 02/16/2006 12:40:00 9.2 0.4 10.3 7.6 9.2 0.5 10.3 6.5 186 3 187 305 -4.8 0 -4.5 -4.9 02/16/2006 12:50:00 8 0.9 9.9 5.3 7.8 1 9.9 5.3 187 5 188 305 -4.6 0 -4 -4.7 02/16/2006 13:00:00 7.8 0.8 9.9 5.3 7.8 0.9 9.5 5.3 187 5 197 305 -4.4 0 -3.8 -4.7 02/16/2006 13:10:00 8.6 0.5 9.9 6.5 9 0.5 10.3 7.2 185 4 188 305 -4.3 0 -3.8 -4.5 02/16/2006 13:20:00 9 0.5 10.3 7.6 9.4 0.6 10.7 7.2 186 4 192 305 -4.2 0 -4 -4.5 02/16/2006 13:30:00 9.3 0.5 10.7 7.6 9.7 0.5 11.1 8.4 187 4 186 305 -4.2 0 -4 -4.2 02/16/2006 13:40:00 9.4 0.5 11.8 8.4 9.7 0.5 11.1 8.4 187 4 197 305 -4.1 0 -3.8 -4.2 02/16/2006 13:50:00 9.4 0.6 10.7 7.6 9.7 0.6 11.1 8 186 3 186 305 -4 0 -3.8 -4 02/16/2006 14:00:00 9.2 1 11.8 6.5 8.9 1 11.5 5.3 189 5 193 305 -3.9 0 -3.3 -4 02/16/2006 14:10:00 8.9 0.8 10.7 6.5 8.8 1.2 11.1 5.3 186 4 188 305 -4 0 -3.8 -4 02/16/2006 14:20:00 9.6 0.5 11.1 8.4 9.9 0.7 11.1 6.8 186 3 188 305 -4 0 -3.8 -4 02/16/2006 14:30:00 9.3 0.8 10.7 7.2 9.1 1 11.5 6.5 186 3 189 305 -4.1 0 -3.8 -4.2 02/16/2006 14:40:00 8.9 0.6 10.7 7.6 8.8 0.8 11.1 6.5 187 3 186 305 -4 0 -3.8 -4.2 02/16/2006 14:50:00 9.1 0.5 10.7 7.6 8.8 0.6 10.3 6.8 187 3 204 305 -4 0 -3.6 -4 02/16/2006 15:00:00 9.2 0.6 11.1 7.6 8.7 0.6 10.3 6.8 190 5 187 305 -4 0 -3.8 -4.2 02/16/2006 15:10:00 9.3 0.6 10.7 7.6 9.1 0.7 10.3 6.5 188 3 188 305 -4.1 0 -3.8 -4.2 02/16/2006 15:20:00 9.4 0.5 11.8 8 9 0.6 10.7 6.8 188 3 196 305 -4.3 0 -4 -4.5 02/16/2006 15:30:00 9.7 0.5 11.1 7.6 9.4 0.6 10.7 7.2 189 3 191 305 -4.4 0 -4.2 -4.5 02/16/2006 15:40:00 9.3 0.7 11.5 8 8.8 0.6 10.7 6.8 190 4 196 305 -4.4 0 -4.2 -4.5 02/16/2006 15:50:00 8.6 0.4 9.9 6.5 8.3 0.6 9.5 6.5 188 3 188 305 -4.4 0 -4 -4.5 02/16/2006 16:00:00 8.5 0.6 10.3 6.1 8.5 0.8 10.7 6.1 188 5 187 305 -4.2 0 -4 -4.5 02/16/2006 16:10:00 9.2 0.4 10.7 8 9.5 0.4 10.7 8 186 2 184 305 -4.1 0 -4 -4.2 02/16/2006 16:20:00 9.1 0.4 10.3 8 9.4 0.5 10.7 7.6 186 2 186 305 -4.2 0 -4 -4.2 02/16/2006 16:30:00 9.4 0.4 10.7 7.6 9.8 0.4 11.1 8.8 187 3 188 305 -4.2 0 -4 -4.5 02/16/2006 16:40:00 9.4 0.5 10.7 8 9.7 0.4 10.7 8.8 186 2 183 305 -4.5 0 -4.2 -4.7 02/16/2006 16:50:00 8 0.8 9.5 5.7 8.2 1.1 9.9 5.3 186 3 189 305 -4.7 0 -4.5 -4.9 02/16/2006 17:00:00 8.1 0.6 9.5 6.1 8.2 0.8 9.9 6.1 186 3 186 305 -4.7 0 -4.5 -4.9 02/16/2006 17:10:00 7.7 1.5 9.9 3.8 9.3 0.7 10.7 6.1 179 6 183 305 -4.5 0.1 -4.2 -4.7 02/16/2006 17:20:00 8.5 1.2 11.1 4.9 9.7 0.6 11.5 8 182 5 186 305 -4.2 0.1 -3.8 -4.5 02/16/2006 17:30:00 8.7 0.5 9.9 7.2 9.1 0.4 10.3 8 185 3 188 305 -4.6 0 -4 -4.7 02/16/2006 17:40:00 8.7 0.6 9.9 6.8 8.9 0.6 9.9 7.6 188 2 188 305 -4.7 0.1 -4.5 -4.9 02/16/2006 17:50:00 8.2 0.4 9.1 6.8 8.5 0.4 9.1 7.2 188 3 186 305 -4.8 0 -4.2 -4.9 02/16/2006 18:00:00 7.9 0.3 8.8 7.2 8.3 0.3 9.1 7.6 190 2 190 305 -4.7 0 -4 -4.9 02/16/2006 18:10:00 8.3 0.3 9.1 7.2 8.4 0.4 9.1 7.2 190 3 192 305 -4.5 0.2 -3.8 -4.7 02/16/2006 18:20:00 7.8 0.5 9.1 6.8 7.9 0.5 9.1 6.5 192 2 193 305 -4.2 0 -3.8 -4.5 02/16/2006 18:30:00 7 1.2 8.4 3 7.5 0.7 8.8 5.3 184 7 196 305 -4.4 0 -4.2 -4.7 02/16/2006 18:40:00 8.6 1.7 12.6 3.4 8.8 1.6 13 5.3 145 11 147 305 -4.5 0.4 -3.6 -5.1 02/16/2006 18:50:00 8.7 1.7 11.5 4.6 9.5 0.8 11.1 7.2 157 7 158 305 -5.5 0.5 -4 -6 02/16/2006 19:00:00 6.4 1.3 10.7 4.2 9.4 0.5 10.7 7.6 165 6 162 305 -5.2 0 -5.1 -5.6 02/16/2006 19:10:00 5.7 1.1 9.5 3.4 8.5 0.7 10.7 6.1 167 7 157 305 -4.9 0.1 -4.2 -5.1 02/16/2006 19:20:00 6.6 1.5 10.7 3.4 9.1 0.6 10.7 7.2 163 8 149 305 -4.6 0.2 -4.2 -5.6 02/16/2006 19:30:00 6 1.5 9.5 3 7.5 1.2 10.3 4.2 164 10 146 305 -5.1 1.1 -2.7 -6 02/16/2006 19:40:00 5.3 1.6 9.5 2.6 6.8 1.1 9.1 4.9 168 10 152 305 -3.3 0.6 -2.7 -4.5 02/16/2006 19:50:00 7.1 1.6 11.8 4.2 8.7 0.7 11.1 6.8 158 7 151 305 -5.5 0.5 -4.5 -6.2 02/16/2006 20:00:00 6.8 1.3 9.5 4.2 8.4 0.5 9.5 7.2 159 5 162 305 -6.2 0 -6 -6.4 02/16/2006 20:10:00 10.5 1.2 13 8 10.9 1 12.6 8.8 144 3 142 305 -6.7 0.4 -6 -7.3 02/16/2006 20:20:00 8.9 0.8 11.5 7.6 10.4 0.8 13 9.1 149 3 145 305 -7.2 0 -7.1 -7.3 02/16/2006 20:30:00 11 1.7 13 7.6 11.2 0.7 12.6 9.5 142 4 141 305 -7.2 0 -6.9 -7.3 02/16/2006 20:40:00 12.4 0.6 13.7 10.7 11.8 0.5 13 10.7 142 2 139 305 -7.1 0 -6.9 -7.3 02/16/2006 20:50:00 12.2 0.4 13.7 11.1 11.6 0.4 12.6 10.7 139 2 142 305 -7 0.1 -6.7 -7.3 02/16/2006 21:00:00 11.6 0.4 12.6 10.3 11.1 0.4 12.2 9.9 136 3 140 305 -6.9 0 -6.7 -7.1 02/16/2006 21:10:00 11.2 0.5 12.6 9.5 10.9 0.5 12.2 9.9 139 2 137 305 -7.3 0.1 -6.9 -7.7 02/16/2006 21:20:00 10.3 0.4 11.1 9.5 10.2 0.3 11.1 9.1 138 4 134 305 -7.5 0.2 -7.1 -7.7 02/16/2006 21:30:00 10.4 0.5 11.8 9.5 10.2 0.5 11.8 9.1 136 3 131 305 -7.1 0 -6.9 -7.3 02/16/2006 21:40:00 10.8 0.4 11.8 9.9 10.7 0.4 11.8 9.1 135 2 133 305 -7.1 0 -6.9 -7.3 02/16/2006 21:50:00 10.5 0.5 11.5 9.1 10.1 0.5 11.1 8.4 137 3 138 305 -7.1 0 -6.9 -7.3 02/16/2006 22:00:00 11.1 0.4 11.8 9.9 10.4 0.5 11.5 8.8 140 2 140 305 -7.1 0 -6.9 -7.3 02/16/2006 22:10:00 11.1 0.7 12.6 9.1 10.8 0.6 12.6 9.5 142 4 140 305 -6.9 0.2 -6.4 -7.1 02/16/2006 22:20:00 10.6 1 13 8.4 10.2 0.9 12.6 8 143 5 141 305 -6.4 0.1 -5.8 -6.7 02/16/2006 22:30:00 9.6 0.6 11.1 8 9.2 0.6 10.7 7.6 141 4 141 305 -6.3 0.1 -5.8 -6.7 02/16/2006 22:40:00 10 0.7 12.2 8.4 9.6 0.7 11.5 8 139 4 140 305 -6.3 0.1 -6 -6.7 02/16/2006 22:50:00 10.2 0.6 11.5 7.6 9.9 0.6 11.5 8 136 3 135 305 -6 0 -5.8 -6.2 02/16/2006 23:00:00 9 1.2 11.5 4.9 8.8 1.1 11.5 5.7 125 9 133 305 -5.5 0.3 -5.1 -6 02/16/2006 23:10:00 8.5 1.1 11.5 5.7 8.1 1 11.5 4.9 115 9 119 305 -5.3 0 -5.1 -5.6 02/16/2006 23:20:00 9.6 1.2 13 6.8 9.4 1.2 12.2 6.5 112 9 111 305 -4.9 0.1 -4.5 -5.3 02/16/2006 23:30:00 9.5 1.3 13 6.5 9.3 1.2 13 6.8 112 9 114 305 -4.6 0 -4.5 -4.7 02/16/2006 23:40:00 9.3 1.3 12.2 4.9 9.1 1.3 12.6 6.1 116 9 107 305 -4.4 0.1 -4 -4.7 02/16/2006 23:50:00 8.1 1.1 13 5.3 8 1.1 11.1 5.7 114 11 96 305 -4.1 0 -3.8 -4.2 02/17/2006 00:00:00 8 1.3 11.8 4.9 7.7 1.3 11.1 4.9 109 12 125 305 -3.9 0 -3.8 -4 02/17/2006 00:10:00 6.9 1.2 10.3 4.2 6.8 1.1 10.3 4.6 105 13 87 305 -3.7 0 -3.3 -3.8 02/17/2006 00:20:00 7.8 1.3 11.5 4.6 7.5 1.3 11.5 3.8 105 12 112 305 -3.3 0 -3.3 -3.6 02/17/2006 00:30:00 6.7 1.5 11.1 1.5 6.6 1.5 11.8 2.6 113 17 131 305 -3.2 0 -3.1 -3.3 02/17/2006 00:40:00 6.3 1.3 10.3 3 6.2 1.3 9.5 3 107 17 85 305 -3.1 0 -2.9 -3.3 02/17/2006 00:50:00 6.3 1.4 9.9 3.4 6.1 1.3 9.5 3.4 105 19 105 305 -3.1 0 -2.9 -3.3 02/17/2006 01:00:00 6.7 1.4 10.7 3.4 6.6 1.3 10.3 3.4 103 17 98 305 -3.1 0 -2.7 -3.3 02/17/2006 01:10:00 6.6 1.5 10.7 3 6.4 1.6 11.5 2.6 91 17 71 305 -3.2 0.1 -2.9 -3.3 02/17/2006 01:20:00 6.3 0.9 9.5 3 6 0.9 8.8 3 74 9 87 305 -3.3 0 -3.1 -3.6 02/17/2006 01:30:00 6.3 1 9.1 2.6 6.2 1 9.9 3.4 68 10 73 305 -3.5 0.1 -2.7 -3.8 02/17/2006 01:40:00 6.2 0.6 7.6 4.6 6.1 0.7 8.4 4.6 67 7 62 305 -3.6 0.1 -3.3 -3.8 02/17/2006 01:50:00 5.4 0.6 7.2 3.8 5.5 0.5 6.8 4.2 64 6 77 305 -3.9 0 -3.6 -4 02/17/2006 02:00:00 6.9 0.9 10.7 5.3 7 1 10.3 4.9 56 9 80 305 -4 0 -3.8 -4.2 02/17/2006 02:10:00 8.6 1.5 13.7 4.6 8.2 1.5 13.3 4.9 81 12 79 305 -3.8 0 -3.6 -4 02/17/2006 02:20:00 8.6 1.2 11.8 6.1 8.2 1.1 11.8 5.3 76 8 74 305 -3.8 0 -3.6 -3.8 02/17/2006 02:30:00 9.8 1.6 13.3 6.8 9.5 1.6 13.3 6.1 70 8 61 305 -3.5 0.1 -3.1 -3.8 02/17/2006 02:40:00 10.7 1.4 14.9 5.3 10.4 1.4 14.1 6.5 75 9 82 305 -3.1 0 -2.7 -3.3 02/17/2006 02:50:00 9.5 1 12.6 6.8 9.3 1 12.6 7.2 68 7 77 305 -3.1 0 -2.4 -3.3 02/17/2006 03:00:00 8.9 1.2 12.6 6.1 8.8 1.1 11.5 6.1 68 8 58 305 -3 0 -2.4 -3.1 02/17/2006 03:10:00 10.9 1.4 15.3 6.8 10.4 1.5 15.3 6.5 74 9 76 305 -2.7 0 -2.2 -2.9 02/17/2006 03:20:00 10.6 2.1 19.9 5.3 10.4 2.3 19.1 5.3 76 15 78 305 -2.6 0.1 -2 -2.7 02/17/2006 03:30:00 10.6 2.6 17.9 1.5 10.4 2.6 19.5 3.8 76 15 81 305 -2.5 0 -2 -2.7 02/17/2006 03:40:00 10.6 1.5 15.3 7.2 10.4 1.5 15.6 6.1 76 11 87 305 -2.4 0 -2 -2.7 02/17/2006 03:50:00 10.5 1.5 14.1 6.8 10.2 1.5 14.1 4.2 74 9 83 305 -2.2 0 -1.8 -2.4 02/17/2006 04:00:00 10.8 2.5 19.1 5.7 10.6 2.5 19.1 5.3 70 15 67 305 -2.2 0 -1.8 -2.2 02/17/2006 04:10:00 10.6 2.4 18.7 5.3 10.4 2.6 20.2 5.7 74 17 86 305 -2.1 0.1 -1.5 -2.2 02/17/2006 04:20:00 10 2.2 15.6 5.3 9.9 2.4 15.3 4.9 73 12 78 305 -2.1 0 -1.8 -2.2 02/17/2006 04:30:00 9.7 1 13.3 6.5 9.4 1.2 14.1 6.5 69 8 61 305 -2 0.1 -1.5 -2.2 02/17/2006 04:40:00 8.9 0.7 11.5 7.2 8.7 0.7 10.7 7.2 64 5 69 305 -2 0 -1.8 -2.2 02/17/2006 04:50:00 7.8 1 10.7 4.2 7.9 1 10.7 4.2 56 9 53 305 -1.9 0 -1.8 -2 02/17/2006 05:00:00 5.9 2.2 10.3 0.4 5.9 2.1 10.7 0.4 61 28 89 305 -1.4 0.2 -1.1 -1.8 02/17/2006 05:10:00 4.2 2.1 9.5 0.4 4.1 2.1 8.4 0.4 86 39 92 305 -1 0 -0.6 -1.1 02/17/2006 05:20:00 5.5 2 11.8 1.5 5.1 1.7 9.5 1.5 84 28 70 305 -0.7 0 -0.6 -0.8 02/17/2006 05:30:00 8.5 2.5 15.6 2.6 8.3 2.6 15.6 1.5 70 20 78 305 -0.7 0 0.1 -0.8 02/17/2006 05:40:00 9.5 2.6 17.2 0.7 9.7 2.6 16.8 3.8 67 16 62 305 -0.7 0 -0.1 -0.8 02/17/2006 05:50:00 7.2 2.3 12.6 2.3 7 2.3 12.6 1.9 87 32 90 305 -0.7 0 -0.1 -1.1 02/17/2006 06:00:00 8 2.6 16.1 2.6 7.7 2.5 16.4 2.6 103 23 107 305 -0.7 0 -0.1 -1.1 02/17/2006 06:10:00 7.8 2.5 15.6 1.9 7.7 2.4 16.1 2.6 103 26 76 305 -0.6 0 0.1 -0.8 02/17/2006 06:20:00 9.3 2.4 14.5 4.2 8.6 2.4 15.3 3.8 105 17 128 305 -0.7 0 0.1 -0.8 02/17/2006 06:30:00 10.2 2.4 16.8 4.9 9.8 2.4 16.4 3.8 108 17 101 305 -0.7 0 -0.6 -0.8 02/17/2006 06:40:00 10.2 2.3 18.3 4.9 9.9 2.4 17.9 3.4 105 17 106 305 -0.6 0 -0.6 -0.6 02/17/2006 06:50:00 10.5 1.9 16.1 5.7 10.2 1.7 15.6 6.5 110 15 119 305 -0.6 0 -0.6 -0.6 02/17/2006 07:00:00 9.7 2.1 14.5 4.2 9.3 2.1 14.9 3.8 107 18 97 305 -0.7 0 -0.6 -0.8 02/17/2006 07:10:00 8.8 2.1 15.6 3.4 8.4 1.9 14.5 4.2 106 20 118 305 -0.9 0 -0.6 -1.1 02/17/2006 07:20:00 9.5 2 15.3 4.9 9.1 2 15.3 4.6 107 17 101 305 -0.7 0 -0.4 -0.8 02/17/2006 07:30:00 8.2 2.3 13.7 1.5 7.8 2.1 12.6 1.5 107 18 117 305 -0.8 0 -0.4 -1.1 02/17/2006 07:40:00 8.6 2.4 15.3 2.6 8.3 2.2 14.5 3.4 105 17 108 305 -1 0 -0.6 -1.1 02/17/2006 07:50:00 8.5 2.2 14.9 4.2 8.3 2.1 15.6 4.6 111 20 118 305 -1.1 0 -1.1 -1.1 02/17/2006 08:00:00 8.2 2 14.1 3.4 8 2 14.5 2.6 112 19 113 305 -1.2 0 -1.1 -1.3 02/17/2006 08:10:00 9 2.6 17.9 3 8.6 2.4 16.1 3.8 113 19 82 305 -1.2 0 -0.6 -1.3 02/17/2006 08:20:00 8.8 2.3 15.3 3.4 8.5 2.2 15.3 3.8 120 17 124 305 -1.4 0 -1.3 -1.5 02/17/2006 08:30:00 7.8 2 14.1 3.4 7.5 2 15.3 3.4 119 19 101 305 -1.4 0 -1.3 -1.5 02/17/2006 08:40:00 7.9 2 14.5 3.8 7.6 2.1 14.9 3.8 119 22 114 305 -1.4 0 -1.3 -1.5 02/17/2006 08:50:00 9.4 2.7 17.2 3.8 8.9 2.7 16.1 3 122 18 113 305 -1.3 0 -1.1 -1.5 02/17/2006 09:00:00 8.2 2.7 16.4 3.4 8.1 2.6 15.6 3 111 27 93 305 -1.3 0 -1.1 -1.5 02/17/2006 09:10:00 8.1 2.4 17.6 3 7.9 2.2 17.6 3.8 107 20 132 305 -1.3 0 -1.1 -1.3 02/17/2006 09:20:00 8.6 2.4 15.3 3.4 8.3 2.4 16.4 3 107 22 88 305 -1.2 0 -1.1 -1.3 02/17/2006 09:30:00 8.3 1.9 14.9 4.2 7.9 1.9 14.5 3.4 111 22 89 305 -1.1 0 -1.1 -1.3 02/17/2006 09:40:00 8.6 2.1 14.5 4.2 8.2 2 14.1 3.8 115 23 116 305 -1 0 -0.8 -1.1 02/17/2006 09:50:00 9.4 2.5 16.4 3.8 9 2.5 16.8 3.8 117 20 143 305 -1 0 -0.8 -1.1 02/17/2006 10:00:00 9.2 2.8 19.5 2.6 8.6 2.6 16.8 2.6 111 22 126 305 -1 0 -0.6 -1.1 02/17/2006 10:10:00 9.7 2.4 18.7 4.6 9.5 2.2 17.2 3.8 115 20 125 305 -1.1 0 -0.8 -1.1 02/17/2006 10:20:00 10.3 2.6 18.3 4.9 10.1 2.5 16.1 5.7 121 18 110 305 -1.1 0 -0.8 -1.1 02/17/2006 10:30:00 8.2 2.3 15.3 3 7.9 2.2 13.7 3 108 22 101 305 -1 0 -0.8 -1.1 02/17/2006 10:40:00 8 2.4 15.3 3 7.6 2.2 16.1 2.6 108 26 105 305 -0.8 0 -0.6 -1.1 02/17/2006 10:50:00 7.8 2.3 14.1 2.6 7.6 2.3 13.7 3 110 22 99 305 -0.9 0 -0.6 -1.1 02/17/2006 11:00:00 7.8 2.2 14.5 2.3 7.5 2.2 14.1 2.3 83 21 96 305 -1 0 -0.8 -1.1 02/17/2006 11:10:00 7.8 2.1 13.3 2.3 7.5 2 11.8 1.9 93 28 90 305 -1 0 -0.8 -1.1 02/17/2006 11:20:00 8.1 2.5 17.2 3.4 7.9 2.6 16.8 1.1 104 23 130 305 -1.1 0 -0.8 -1.1 02/17/2006 11:30:00 8.4 3.1 18.3 3.4 8.1 2.9 18.7 3 100 22 110 305 -1.2 0 -1.1 -1.3 02/17/2006 11:40:00 8.7 2.3 16.1 2.3 8.3 2.3 15.3 2.6 94 24 78 305 -1.2 0 -1.1 -1.3 02/17/2006 11:50:00 8.6 2.3 17.2 3.4 8.1 2.1 13.3 2.6 96 26 82 305 -1.1 0 -1.1 -1.3 02/17/2006 12:00:00 8 2 13.3 3.4 7.8 1.9 14.9 3.4 88 27 92 305 -1.1 0 -1.1 -1.3 02/17/2006 12:10:00 8.3 2.4 14.5 2.3 8 2.2 14.1 3 106 18 99 305 -1.1 0 -1.1 -1.3 02/17/2006 12:20:00 8.7 2.3 14.9 2.6 8.2 2.1 14.5 4.6 104 22 102 305 -1.1 0 -1.1 -1.1 02/17/2006 12:30:00 7.9 2 12.2 2.3 7.8 1.7 12.6 3 98 22 98 305 -1.1 0 -1.1 -1.3 02/17/2006 12:40:00 7.6 2.4 15.3 2.6 7.4 2.3 14.5 1.1 100 27 119 305 -1.1 0 -1.1 -1.1 02/17/2006 12:50:00 7.2 2 12.6 1.5 7.1 1.9 12.2 2.3 86 21 82 305 -1.1 0 -1.1 -1.1 02/17/2006 13:00:00 6.6 1.5 12.2 2.6 6.2 1.5 11.1 2.6 106 21 102 305 -1.1 0 -1.1 -1.1 02/17/2006 13:10:00 6.6 2.3 13.7 2.6 6.3 2.3 13 1.5 104 24 105 305 -1.1 0 -1.1 -1.1 02/17/2006 13:20:00 7.1 2 13.3 3 6.8 1.9 13 3 90 21 84 305 -1.1 0 -1.1 -1.1 02/17/2006 13:30:00 8.6 2.3 14.9 3.8 8.2 2.3 13.7 4.2 89 27 83 305 -1.1 0 -0.8 -1.1 02/17/2006 13:40:00 8.8 2.6 16.4 3 8.6 2.6 17.6 3.4 85 23 70 305 -1 0 -0.8 -1.1 02/17/2006 13:50:00 8.6 2.1 14.9 1.9 8.3 2 14.5 2.6 94 23 79 305 -0.9 0 -0.6 -1.1 02/17/2006 14:00:00 9.8 2.5 17.2 3.8 9.3 2.4 16.4 3.8 111 17 118 305 -0.8 0 -0.4 -0.8 02/17/2006 14:10:00 12 2 17.9 5.7 11.8 1.9 17.2 6.1 123 17 126 305 -0.8 0 -0.6 -1.1 02/17/2006 14:20:00 13.2 2.2 18.7 7.2 12.9 2.2 17.9 8 126 13 126 305 -0.9 0 -0.6 -1.1 02/17/2006 14:30:00 14.1 1.8 18.3 9.5 13.8 1.7 18.7 9.1 128 9 117 305 -0.9 0 -0.4 -1.1 02/17/2006 14:40:00 13.8 2 19.5 8 13.5 2.1 20.6 7.6 126 11 118 305 -0.9 0 -0.6 -1.1 02/17/2006 14:50:00 13.4 2 17.9 8 13.3 1.9 17.2 6.8 127 12 121 305 -0.8 0 -0.6 -1.1 02/17/2006 15:00:00 14.8 2.4 21.8 7.2 14.6 2.1 21 8.8 125 12 124 305 -0.7 0 -0.6 -0.8 02/17/2006 15:10:00 15 2.2 21 8.8 14.9 2.1 20.6 8.4 124 12 104 305 -0.8 0 -0.6 -0.8 02/17/2006 15:20:00 15.6 1.8 21.8 10.3 15.3 1.8 21 9.1 129 9 128 305 -0.7 0 -0.6 -0.8 02/17/2006 15:30:00 15 2.1 24 10.7 14.7 2 22.9 9.9 130 11 121 305 -0.7 0 -0.6 -0.8 02/17/2006 15:40:00 14.2 2.3 24 9.1 13.9 2.3 22.6 7.6 125 13 112 305 -0.7 0 -0.6 -0.8 02/17/2006 15:50:00 12.1 2.6 18.3 6.1 12.1 2.7 17.6 5.7 122 14 115 305 -0.7 0 -0.6 -0.8 02/17/2006 16:00:00 10 2.5 16.1 4.9 9.6 2.5 17.2 4.2 112 16 144 305 -0.7 0 -0.6 -0.8 02/17/2006 16:10:00 7 2.3 15.6 1.1 6.8 2 14.9 1.5 106 19 110 305 -0.7 0 -0.6 -0.8 02/17/2006 16:20:00 7.1 2.3 14.1 1.5 7 2.3 13.3 2.3 92 24 67 305 -0.8 0 -0.6 -1.1 02/17/2006 16:30:00 7.2 2.2 13 1.5 7.1 2.1 13.3 2.6 85 24 67 305 -1 0.1 -0.4 -1.1 02/17/2006 16:40:00 7.3 2.5 15.6 1.9 7 2.4 14.1 1.9 85 20 67 305 -0.9 0 -0.4 -1.1 02/17/2006 16:50:00 6.6 1.7 11.1 1.1 6.7 1.6 11.1 3 95 29 110 305 -0.8 0 -0.4 -1.1 02/17/2006 17:00:00 6.4 2.4 14.1 1.5 6.5 2.3 14.1 1.9 96 29 140 305 -0.9 0 -0.4 -1.1 02/17/2006 17:10:00 7.3 2.2 14.1 3.4 7 2.3 14.5 2.6 101 26 123 305 -1 0 -0.6 -1.1 02/17/2006 17:20:00 7.8 2.3 13.3 3.4 7.5 2.3 13 2.6 108 22 86 305 -1.1 0 -0.8 -1.1 02/17/2006 17:30:00 7.5 2.3 14.5 2.6 7.2 2.2 13.3 3 109 22 67 305 -1.1 0 -0.8 -1.3 02/17/2006 17:40:00 8.6 1.7 14.5 4.2 8.3 1.7 12.2 4.2 114 20 110 305 -1.1 0 -1.1 -1.3 02/17/2006 17:50:00 8.4 2.1 16.4 3 8.2 2 13.7 3.8 111 19 94 305 -1.2 0 -0.6 -1.3 02/17/2006 18:00:00 8.7 1.9 14.9 4.6 8.5 1.7 13.7 4.2 109 19 102 305 -1.2 0 -0.6 -1.3 02/17/2006 18:10:00 8.8 2.3 14.5 2.3 8.3 2.1 13.7 2.6 115 22 104 305 -1.2 0 -0.6 -1.3 02/17/2006 18:20:00 10.4 2.2 16.4 4.2 10.1 2.1 15.6 6.1 115 17 107 305 -1.1 0 -0.6 -1.3 02/17/2006 18:30:00 10.1 2.5 15.3 4.9 9.9 2.3 16.8 4.6 115 14 97 305 -1.1 0 -0.6 -1.3 02/17/2006 18:40:00 10.2 2.2 16.8 5.3 9.8 2.2 15.3 4.6 114 18 118 305 -1.1 0 -0.6 -1.3 02/17/2006 18:50:00 11.9 2.1 17.6 6.1 11.6 2.2 17.2 4.2 116 14 123 305 -1.1 0 -0.6 -1.1 02/17/2006 19:00:00 11.4 2.1 16.8 6.8 11 2.1 16.4 6.1 118 13 124 305 -1.1 0 -0.6 -1.1 02/17/2006 19:10:00 12.2 2.2 18.3 4.6 11.8 2.1 18.3 4.9 121 12 112 305 -1.1 0 -0.6 -1.3 02/17/2006 19:20:00 12.4 2.3 17.9 6.1 11.9 2.4 17.9 5.3 118 12 105 305 -1.1 0 -0.6 -1.3 02/17/2006 19:30:00 12.3 2.2 17.6 6.1 11.8 2.1 17.6 6.8 119 12 116 305 -1.1 0 -0.6 -1.3 02/17/2006 19:40:00 11.2 2.2 17.2 6.5 10.7 2.2 17.2 4.9 121 12 125 305 -1.1 0 -0.6 -1.3 02/17/2006 19:50:00 10.7 1.8 16.8 6.5 10.3 1.7 16.4 6.5 124 14 143 305 -1.1 0 -0.6 -1.3 02/17/2006 20:00:00 12.1 1.9 16.4 6.8 11.8 1.8 16.8 7.2 133 10 140 305 -1.1 0 -0.6 -1.1 02/17/2006 20:10:00 12.6 1.3 16.1 8.8 12.2 1.2 15.3 9.1 133 6 143 305 -1 0 -0.6 -1.1 02/17/2006 20:20:00 12 1.1 14.1 8 11.8 1.1 14.1 8 131 5 139 305 -1 0.1 -0.6 -1.1 02/17/2006 20:30:00 11.9 1.1 15.6 8.8 11.6 1.1 15.3 9.1 134 6 135 305 -1.1 0.1 -0.6 -1.1 02/17/2006 20:40:00 12.8 1.1 15.3 9.1 12.4 1.1 15.3 9.5 135 6 129 305 -1 0 -0.6 -1.1 02/17/2006 20:50:00 11.6 1.4 14.9 6.8 11.3 1.3 13.7 7.2 137 8 136 305 -1 0.1 -0.6 -1.1 02/17/2006 21:00:00 11.6 1.7 15.3 6.8 11.3 1.6 15.3 6.1 138 8 134 305 -1 0.1 -0.4 -1.1 02/17/2006 21:10:00 10.1 1.5 14.1 6.1 10.1 1.5 14.1 6.5 142 9 144 305 -1 0.1 -0.6 -1.1 02/17/2006 21:20:00 10.7 1.5 14.9 6.8 10.6 1.5 15.3 6.8 147 9 150 305 -1 0.1 -0.4 -1.1 02/17/2006 21:30:00 11.3 1.8 15.3 5.3 11.1 1.5 14.9 6.8 148 8 142 305 -1 0.1 -0.6 -1.1 02/17/2006 21:40:00 10.7 2.1 14.9 4.9 10.8 1.5 15.3 6.5 150 10 156 305 -1 0.1 -0.4 -1.1 02/17/2006 21:50:00 10.1 1.8 14.1 6.1 10.4 1.5 15.3 6.8 152 9 151 305 -0.9 0 -0.4 -1.1 02/17/2006 22:00:00 10.3 2 14.9 6.1 10.8 1.6 16.4 6.5 155 10 155 305 -0.9 0 -0.4 -1.1 02/17/2006 22:10:00 10.9 1.6 15.6 6.5 12 1.4 15.3 8.4 157 8 147 305 -0.8 0 -0.6 -1.1 02/17/2006 22:20:00 10.6 1.6 15.6 7.2 12.4 0.9 15.3 9.9 159 6 154 305 -0.8 0 -0.6 -0.8 02/17/2006 22:30:00 9.5 1.3 14.5 6.8 12.4 1 14.9 9.9 162 5 154 305 -0.8 0 -0.6 -0.8 02/17/2006 22:40:00 8.9 1.2 12.2 6.8 13.3 1.1 16.1 10.3 166 5 169 305 -0.7 0 -0.6 -0.8 02/17/2006 22:50:00 8.5 1.3 13.3 5.3 12.2 1.2 15.6 9.5 170 6 180 305 -0.6 0 -0.6 -0.6 02/17/2006 23:00:00 9.1 1.7 12.6 4.9 11.7 1 14.1 8.8 176 6 180 305 -0.6 0 -0.6 -0.6 02/17/2006 23:10:00 10.2 1.5 13.7 6.1 11.9 1 14.5 9.1 179 5 184 305 -0.7 0 -0.6 -0.8 02/17/2006 23:20:00 11.5 1 13.7 8 11.8 0.8 13.7 9.5 183 4 186 305 -0.8 0 -0.6 -1.1 02/17/2006 23:30:00 12.8 1 16.1 10.7 12.7 1 15.3 9.9 185 4 186 305 -1 0 -0.6 -1.1 02/17/2006 23:40:00 13.7 1 16.4 10.7 13.5 1.1 16.4 10.7 188 4 184 305 -1.1 0 -1.1 -1.3 02/17/2006 23:50:00 11.6 0.8 13.7 9.5 11.5 0.8 13.7 9.5 186 4 193 305 -1.6 0.2 -1.1 -2 02/18/2006 00:00:00 11.4 0.6 13 9.5 11.2 0.7 13.3 8.8 185 3 188 305 -2.2 0 -2 -2.2 02/18/2006 00:10:00 11.6 0.8 14.1 9.9 11.3 0.8 13.7 8.8 188 4 186 305 -2.1 0 -2 -2.4 02/18/2006 00:20:00 11.4 0.7 13.7 9.5 11.3 0.7 13.3 9.5 185 3 190 305 -2.1 0 -2 -2.2 02/18/2006 00:30:00 11.9 0.9 14.1 9.1 11.8 0.9 14.1 9.5 185 3 187 305 -2.2 0 -2 -2.4 02/18/2006 00:40:00 11.6 0.7 13.7 9.5 11.5 0.7 13.7 9.5 185 3 186 305 -2.1 0 -2 -2.4 02/18/2006 00:50:00 11.4 0.7 13.7 9.1 11.2 0.8 13 8 185 3 185 305 -2.2 0 -2 -2.4 02/18/2006 01:00:00 11.3 0.7 13.3 9.1 11.1 0.8 13 8.4 186 3 183 305 -2 0 -1.5 -2.2 02/18/2006 01:10:00 11.5 0.8 13.3 9.5 11.4 0.8 13.7 8.8 185 3 190 305 -2.1 0 -1.8 -2.2 02/18/2006 01:20:00 11.3 1 13.3 8 12.2 1 14.1 8.4 181 4 181 305 -1.8 0.1 -1.3 -2 02/18/2006 01:30:00 10.7 1.2 13.7 7.2 12 1 14.1 8.8 179 4 183 305 -1.6 0 -1.3 -1.8 02/18/2006 01:40:00 10.4 1.7 14.5 5.7 13.1 1.1 15.6 9.9 176 5 188 305 -1.2 0.1 -0.8 -1.8 02/18/2006 01:50:00 9.9 2 15.3 5.7 12.5 1.3 16.4 9.1 175 6 179 305 -1.2 0 -0.6 -1.3 02/18/2006 02:00:00 8.8 1.7 13.7 5.3 11.8 1.2 15.6 9.1 173 6 179 305 -1.2 0 -1.1 -1.3 02/18/2006 02:10:00 8.9 1.5 13.3 5.3 12.8 1.2 16.4 9.9 171 6 174 305 -1.4 0 -1.1 -1.5 02/18/2006 02:20:00 8.9 1.4 13.3 6.1 13.9 1.1 16.8 11.1 168 5 177 305 -1.5 0 -1.1 -1.5 02/18/2006 02:30:00 8.4 1 11.8 6.1 13.6 1 16.8 10.7 167 5 171 305 -1.5 0 -1.3 -1.8 02/18/2006 02:40:00 8.6 1.2 14.1 6.1 13.4 1 15.6 9.9 167 5 177 305 -1.6 0 -1.3 -1.8 02/18/2006 02:50:00 8.1 1.2 12.2 5.7 12.1 1.5 15.3 8.8 165 5 162 305 -1.8 0 -1.3 -2 02/18/2006 03:00:00 8.6 1.4 13.3 5.7 12.7 1.2 16.4 9.9 165 5 176 305 -1.6 0 -1.3 -2 02/18/2006 03:10:00 8.3 1.3 12.2 4.6 9.9 1.3 13 7.2 159 6 154 305 -2.2 0.2 -1.8 -2.7 02/18/2006 03:20:00 8.4 1.4 12.2 4.9 9.6 0.9 11.8 7.6 158 6 151 305 -2.5 0 -2.2 -2.7 02/18/2006 03:30:00 8.8 1.5 13 5.7 10.6 0.9 13 8 160 5 159 305 -2.5 0 -2.4 -2.7 02/18/2006 03:40:00 9.7 1.7 13.7 5.3 10.9 0.9 13 8 159 5 155 305 -2.6 0.1 -2.4 -2.7 02/18/2006 03:50:00 9.5 1.7 14.1 6.1 11.3 0.9 13.7 8 160 6 151 305 -2.7 0 -2.4 -2.7 02/18/2006 04:00:00 9.8 1.5 14.5 5.7 10.7 1 13.3 8.4 157 6 148 305 -2.7 0 -2.4 -2.7 02/18/2006 04:10:00 10.8 1.7 15.3 6.1 10.9 1.2 14.5 8.4 155 6 152 305 -2.8 0 -2.7 -2.9 02/18/2006 04:20:00 11.1 1.3 14.1 7.6 11.1 1.1 13.7 8.4 152 6 152 305 -2.8 0 -2.4 -3.1 02/18/2006 04:30:00 10.7 1.3 13.3 7.6 10.4 1.2 13 6.8 144 8 143 305 -3 0.2 -2.7 -3.3 02/18/2006 04:40:00 11.2 1.3 14.9 8 10.8 1.2 14.1 8 144 8 151 305 -3.3 0 -2.9 -3.6 02/18/2006 04:50:00 11.2 1.1 14.1 8.8 10.9 1.1 13.3 8.4 147 6 148 305 -3.4 0 -3.3 -3.8 02/18/2006 05:00:00 11.5 1.1 14.9 8.8 11.2 1 13.3 8 146 6 146 305 -3.7 0 -3.3 -3.8 02/18/2006 05:10:00 11.3 1.1 14.1 8.4 11 1 13.3 8.8 147 6 150 305 -3.7 0 -3.6 -3.8 02/18/2006 05:20:00 11.2 1.2 14.5 8.4 11 1 13.7 8.4 145 7 149 305 -3.7 0 -3.6 -3.8 02/18/2006 05:30:00 11.3 1.1 14.1 8.4 11 1.1 13.7 8 144 7 149 305 -3.9 0 -3.8 -3.8 02/18/2006 05:40:00 11.1 1.1 14.1 8 10.9 1.1 14.1 8.4 143 7 152 305 -3.8 0 -3.6 -3.8 02/18/2006 05:50:00 12.1 1 14.9 9.1 11.8 1 14.9 9.5 140 6 145 305 -3.7 0 -3.6 -3.8 02/18/2006 06:00:00 12 1 15.3 9.1 11.7 1 14.1 9.1 139 6 137 305 -3.7 0 -3.3 -3.8 02/18/2006 06:10:00 11.9 0.9 14.5 9.1 11.5 0.9 14.5 9.1 138 6 136 305 -3.7 0 -3.3 -3.8 02/18/2006 06:20:00 11.6 1 13.7 8.4 11.3 1 13.3 8.4 138 6 131 305 -3.7 0 -3.3 -3.8 02/18/2006 06:30:00 10.9 0.9 14.1 8.8 10.6 0.9 13.7 8.4 137 5 145 305 -3.7 0 -3.6 -3.8 02/18/2006 06:40:00 10.4 0.9 12.2 7.6 10.1 0.8 12.2 7.2 132 4 134 305 -3.6 0 -3.3 -3.8 02/18/2006 06:50:00 9.9 1 12.2 7.6 9.6 1 12.2 7.2 127 7 136 305 -3.4 0 -2.7 -3.6 02/18/2006 07:00:00 10.6 0.9 13 8 10.2 1 13 7.6 128 7 136 305 -3.2 0 -2.7 -3.3 02/18/2006 07:10:00 10 0.9 12.2 6.8 9.7 0.8 12.2 8 130 6 129 305 -3.2 0 -2.7 -3.3 02/18/2006 07:20:00 9.7 1.1 13 7.2 9.5 1.1 12.6 6.5 129 7 122 305 -3 0 -2.4 -3.1 02/18/2006 07:30:00 10.4 1 13.3 7.6 10.1 1 12.6 7.6 131 5 139 305 -2.8 0 -2.7 -3.1 02/18/2006 07:40:00 10 1.5 14.5 4.9 9.7 1.5 13.7 5.3 131 10 152 305 -2.8 0 -2.2 -2.9 02/18/2006 07:50:00 7.8 1.6 12.6 3.8 7.8 1.7 11.5 4.2 129 15 138 305 -2.7 0 -2.2 -2.7 02/18/2006 08:00:00 9 1.5 14.9 5.7 8.9 1.5 14.1 5.7 133 11 116 305 -2.6 0 -2.4 -2.7 02/18/2006 08:10:00 8.1 1.6 12.6 4.2 8.1 1.5 12.6 3.8 127 14 135 305 -2.5 0 -2.4 -2.7 02/18/2006 08:20:00 7.5 1.5 11.5 3.8 7.4 1.4 13 4.2 123 14 113 305 -2.5 0 -2.4 -2.7 02/18/2006 08:30:00 7.5 1.6 12.2 3.4 7.4 1.5 12.2 3.4 117 18 121 305 -2.5 0 -2.4 -2.7 02/18/2006 08:40:00 8.1 1.5 11.8 4.2 7.8 1.7 12.2 4.6 115 15 124 305 -2.5 0 -2.4 -2.7 02/18/2006 08:50:00 7.9 1.6 12.2 3.4 7.3 1.5 12.2 2.6 116 17 118 305 -2.4 0 -2.2 -2.4 02/18/2006 09:00:00 8 1.5 12.2 4.9 7.7 1.6 13.3 3.8 117 14 100 305 -2.2 0 -2.2 -2.4 02/18/2006 09:10:00 7.3 1.7 13 3 7 1.5 13.3 3.4 118 17 136 305 -2.1 0 -2 -2.2 02/18/2006 09:20:00 7.6 1.7 11.8 3.8 7.2 1.6 10.7 3.8 115 19 114 305 -1.9 0 -1.8 -2 02/18/2006 09:30:00 8.3 1.5 12.2 4.6 7.9 1.3 11.1 4.9 115 17 127 305 -1.8 0 -1.8 -2 02/18/2006 09:40:00 7 1.8 12.2 3 6.9 1.7 11.8 3 102 18 89 305 -1.7 0 -1.8 -1.8 02/18/2006 09:50:00 6.2 1.6 10.3 2.3 5.9 1.6 9.9 0.7 99 24 95 305 -1.7 0 -1.3 -2 02/18/2006 10:00:00 6 1.7 11.1 2.3 5.8 1.6 11.8 2.3 85 22 88 305 -1.7 0 -1.8 -1.8 02/18/2006 10:10:00 7.8 2.2 14.9 2.3 7.8 2.2 16.4 3 70 21 61 305 -1.7 0 -1.8 -1.8 02/18/2006 10:20:00 9.2 2 15.3 4.6 9.1 2.1 14.9 4.6 69 13 64 305 -1.8 0 -1.8 -2 02/18/2006 10:30:00 10.2 1.4 13.3 6.1 9.9 1.4 13.7 5.7 72 8 78 305 -1.9 0 -1.5 -2 02/18/2006 10:40:00 10.4 1.2 14.5 6.1 10.2 1.2 14.1 7.2 72 8 75 305 -1.9 0 -1.8 -2 02/18/2006 10:50:00 11.5 2 17.9 7.2 11.5 2.2 18.3 6.5 73 11 66 305 -1.8 0 -1.5 -2 02/18/2006 11:00:00 11.1 1.5 14.5 6.8 10.8 1.6 15.6 6.5 74 10 71 305 -1.8 0 -1.3 -2 02/18/2006 11:10:00 12 1.3 16.1 8.4 11.7 1.5 14.9 7.6 74 8 87 305 -1.7 0 -1.8 -2 02/18/2006 11:20:00 11.4 1.2 14.5 8 11.1 1.2 14.5 8.4 71 7 72 305 -1.7 0 -1.3 -1.8 02/18/2006 11:30:00 11.4 1.1 15.3 7.2 11.2 1.2 14.9 8.4 72 6 73 305 -1.6 0 -1.5 -1.8 02/18/2006 11:40:00 11.3 1 14.9 8.8 11.1 1.1 14.5 8.4 68 6 62 305 -1.6 0 -1.1 -1.8 02/18/2006 11:50:00 11.2 0.9 13.7 8.4 10.9 1 13.7 8.8 69 6 61 305 -1.6 0 -1.1 -1.8 02/18/2006 12:00:00 11.2 0.8 14.1 8.8 11.1 0.8 13 8.8 69 6 61 305 -1.5 0 -1.1 -1.8 02/18/2006 12:10:00 11.1 0.9 14.1 9.1 10.8 1 13.3 8.4 67 5 68 305 -1.5 0 -1.1 -1.8 02/18/2006 12:20:00 10.5 0.7 12.6 8.4 10 0.8 12.6 8 66 5 76 305 -1.6 0 -1.1 -1.8 02/18/2006 12:30:00 10.1 0.8 12.6 8 9.7 1 12.6 7.6 67 5 63 305 -1.5 0 -1.3 -1.8 02/18/2006 12:40:00 8.9 0.7 10.7 7.2 8.6 0.8 11.1 6.1 65 5 72 305 -1.6 0 -1.1 -1.8 02/18/2006 12:50:00 8.3 0.5 9.5 6.8 7.9 0.6 9.5 6.5 63 3 64 305 -1.6 0 -1.3 -1.8 02/18/2006 13:00:00 7.3 0.6 8.8 6.1 7.1 0.6 8.8 5.7 59 4 60 305 -1.6 0 -1.3 -1.8 02/18/2006 13:10:00 6.9 0.6 8 5.3 6.7 0.6 8.4 4.9 56 3 59 305 -1.6 0 -1.3 -1.8 02/18/2006 13:20:00 6.2 0.5 7.6 4.9 6.1 0.5 7.6 4.9 54 4 59 305 -1.6 0 -1.1 -1.8 02/18/2006 13:30:00 5.9 0.4 6.8 4.9 5.8 0.4 6.8 4.6 50 3 51 305 -1.6 0 -1.3 -1.8 02/18/2006 13:40:00 4.8 0.5 6.1 3.4 4.7 0.5 5.7 3.4 43 4 46 305 -1.6 0 -1.5 -1.8 02/18/2006 13:50:00 3.6 0.5 4.6 2.6 3.6 0.5 4.9 2.6 29 9 44 305 -1.5 0 -1.3 -1.8 02/18/2006 14:00:00 3.5 0.4 4.6 2.6 3.7 0.5 4.9 2.6 358 10 347 305 -1.5 0 -1.3 -1.8 02/18/2006 14:10:00 3.9 0.4 4.9 3 4.2 0.3 4.9 3.4 8 8 7 305 -1.5 0 -1.3 -1.8 02/18/2006 14:20:00 3.4 0.4 4.6 2.3 3.3 0.5 4.9 1.9 337 15 0 305 -1.4 0 -1.3 -1.5 02/18/2006 14:30:00 3.9 0.5 4.9 3 3.8 0.4 4.6 2.6 317 15 307 305 -1.4 0 -1.3 -1.5 02/18/2006 14:40:00 5 0.4 6.1 4.2 4.4 0.3 5.3 3.8 307 23 299 305 -1.5 0 -1.1 -1.8 02/18/2006 14:50:00 5.7 0.4 6.5 4.6 4.7 0.4 5.7 3.4 289 5 296 305 -1.6 0 -1.1 -1.8 02/18/2006 15:00:00 6.4 0.7 8.4 4.2 5.2 0.7 6.8 2.6 283 6 278 305 -1.6 0 -1.1 -1.8 02/18/2006 15:10:00 6.8 0.6 8.4 5.3 5.2 0.8 7.2 3 279 6 281 305 -1.5 0 -1.1 -1.8 02/18/2006 15:20:00 7.2 1 9.5 3.8 5.1 0.8 6.8 2.3 270 7 282 305 -1.5 0 -1.1 -1.8 02/18/2006 15:30:00 7.5 0.9 9.5 4.6 5 0.8 7.2 2.6 267 7 266 305 -1.6 0 -1.1 -1.8 02/18/2006 15:40:00 8.4 1 10.7 4.9 5.7 0.9 7.6 3 265 8 265 305 -1.6 0 -1.1 -1.8 02/18/2006 15:50:00 8.8 1.1 11.8 5.7 6.3 1 8.8 3.8 268 9 262 305 -1.7 0 -1.1 -1.8 02/18/2006 16:00:00 9.7 1.1 12.2 6.8 6.9 1 9.9 4.2 270 7 269 305 -1.7 0 -1.8 -1.8 02/18/2006 16:10:00 9.2 1.2 11.8 5.3 6.5 1 9.1 3.8 266 8 265 305 -1.6 0 -1.1 -1.8 02/18/2006 16:20:00 9.7 1.3 12.6 5.7 7.1 1.1 10.3 3.8 260 7 256 305 -1.7 0 -1.1 -1.8 02/18/2006 16:30:00 10.6 1.1 13.7 7.2 8.2 1.3 12.2 4.9 257 7 250 305 -1.7 0 -1.3 -1.8 02/18/2006 16:40:00 12.6 1.5 16.4 6.8 10.5 1.9 15.3 4.6 253 6 259 305 -1.8 0 -1.3 -2 02/18/2006 16:50:00 14.1 1.5 17.6 9.5 11.5 1.7 15.6 6.8 255 6 253 305 -1.8 0 -1.3 -2 02/18/2006 17:00:00 14.9 2 19.9 9.9 11.8 2.2 18.7 7.2 258 7 258 305 -2 0 -1.8 -2.2 02/18/2006 17:10:00 17.4 2.2 23.3 10.3 14.2 2.2 19.9 7.6 258 7 262 305 -2.4 0.2 -2 -2.7 02/18/2006 17:20:00 18.6 2.4 23.7 13 15.4 2.3 20.6 9.9 260 7 260 305 -3 0.1 -2.4 -3.1 02/18/2006 17:30:00 17 2.4 23.7 9.9 14.3 2.4 19.9 8.8 257 7 269 305 -3.2 0 -3.1 -3.3 02/18/2006 17:40:00 16.6 2.2 23.3 9.9 14.1 2.2 19.5 7.6 257 8 265 305 -3.3 0 -2.7 -3.3 02/18/2006 17:50:00 16.1 2.4 22.1 9.9 13.6 2.4 20.6 8.4 256 8 253 305 -3.5 0 -3.3 -3.6 02/18/2006 18:00:00 15 1.9 19.1 9.9 12.9 2.2 19.1 6.5 254 7 256 305 -3.3 0 -3.1 -3.6 02/18/2006 18:10:00 14.9 1.5 18.7 9.9 13.2 1.8 16.8 8 251 6 249 305 -3.2 0 -3.1 -3.3 02/18/2006 18:20:00 14.7 1.7 18.3 10.7 13.5 1.9 17.6 8.8 246 6 245 305 -3.2 0 -3.1 -3.3 02/18/2006 18:30:00 15.4 1.4 19.9 12.2 14.3 1.5 19.1 10.3 241 6 247 305 -3.3 0 -3.1 -3.6 02/18/2006 18:40:00 16.1 1.7 21 12.2 15 1.9 20.2 9.5 240 6 248 305 -3.6 0 -3.3 -3.8 02/18/2006 18:50:00 15.2 1.7 19.1 11.1 14.1 1.7 18.7 9.5 240 6 235 305 -3.7 0 -3.6 -3.8 02/18/2006 19:00:00 15.4 1.7 19.1 11.8 14.5 1.6 18.3 10.7 238 5 239 305 -3.7 0 -3.6 -3.8 02/18/2006 19:10:00 15.8 1.7 19.9 10.7 14.5 1.7 18.7 10.7 235 5 227 305 -3.6 0 -3.3 -3.8 02/18/2006 19:20:00 16 1.8 20.6 11.8 14.6 2 20.2 10.3 232 5 228 305 -3.6 0 -3.6 -3.8 02/18/2006 19:30:00 16.1 1.9 20.2 11.5 14.7 2 20.2 9.9 232 5 234 305 -3.7 0 -3.6 -3.8 02/18/2006 19:40:00 16.5 1.8 21 11.8 15.3 1.9 19.1 10.7 228 5 228 305 -3.9 0 -3.8 -4 02/18/2006 19:50:00 16.1 1.5 20.6 12.2 14.9 1.7 19.9 11.1 228 6 222 305 -3.9 0 -3.8 -4 02/18/2006 20:00:00 17 1.8 22.9 12.6 16 2 21.4 11.1 227 6 225 305 -4.1 0 -3.8 -4.2 02/18/2006 20:10:00 16.5 1.6 21 12.2 15.5 1.7 20.2 11.1 227 6 226 305 -4.2 0 -3.8 -4.5 02/18/2006 20:20:00 16.2 1.7 19.9 11.1 15 1.6 18.7 9.9 227 6 231 305 -4.5 0 -4.2 -4.7 02/18/2006 20:30:00 16.1 1.5 20.2 11.5 14.9 1.6 19.5 10.7 227 5 230 305 -4.6 0 -4.5 -4.7 02/18/2006 20:40:00 14.6 1.3 17.9 10.7 13.6 1.5 17.2 9.5 227 5 230 305 -4.6 0 -4.2 -4.7 02/18/2006 20:50:00 14.6 1.3 17.9 10.3 13.5 1.5 17.2 9.1 227 6 234 305 -4.6 0 -4.2 -4.7 02/18/2006 21:00:00 14.6 1.4 18.3 9.9 13.5 1.5 17.9 9.1 228 6 236 305 -4.6 0 -4 -4.7 02/18/2006 21:10:00 14.3 1.5 18.7 10.7 13.2 1.5 16.4 9.9 231 6 230 305 -4.5 0 -3.8 -4.7 02/18/2006 21:20:00 15 1.7 18.7 9.9 13.8 1.7 18.3 8.8 233 6 225 305 -4.3 0.1 -3.8 -4.5 02/18/2006 21:30:00 15.5 1.6 19.9 10.7 14.5 1.5 19.1 10.7 235 7 232 305 -4.3 0 -3.8 -4.5 02/18/2006 21:40:00 14.7 1.6 19.1 10.7 13.7 1.7 17.6 9.5 235 6 234 305 -4.2 0 -3.8 -4.5 02/18/2006 21:50:00 15.5 1.9 20.2 11.1 14.4 1.9 18.3 9.5 237 6 239 305 -4.2 0 -4 -4.5 02/18/2006 22:00:00 15 1.7 20.2 10.3 14 1.7 18.3 9.1 239 6 250 305 -4.1 0 -4 -4.2 02/18/2006 22:10:00 14.4 1.5 18.3 11.1 13.3 1.5 16.8 9.9 235 6 234 305 -4.2 0 -4 -4.5 02/18/2006 22:20:00 15.3 1.5 18.3 9.9 14.2 1.6 18.3 9.5 232 5 224 305 -4.3 0 -4 -4.5 02/18/2006 22:30:00 14.3 1.3 17.6 10.7 13.1 1.5 16.4 9.9 226 5 224 305 -4.5 0 -4.2 -4.7 02/18/2006 22:40:00 15.3 1.4 18.3 11.1 14.3 1.5 18.3 10.3 225 5 236 305 -4.5 0 -4.2 -4.7 02/18/2006 22:50:00 16.1 1.5 19.1 11.1 14.9 1.7 18.3 9.9 224 5 224 305 -4.4 0 -4.2 -4.7 02/18/2006 23:00:00 15.7 1.6 19.5 10.7 14.5 1.7 19.1 9.9 222 5 227 305 -4.6 0 -4.5 -4.7 02/18/2006 23:10:00 15.4 1.7 19.1 10.3 14 1.8 18.3 9.1 223 5 223 305 -4.7 0.1 -4.5 -4.9 02/18/2006 23:20:00 15.2 1.4 18.3 10.7 13.8 1.5 17.9 10.3 222 5 221 305 -5 0 -4.7 -5.3 02/18/2006 23:30:00 15.6 1.3 19.5 12.6 14.4 1.5 18.3 11.1 220 5 224 305 -5.2 0 -5.1 -5.3 02/18/2006 23:40:00 14.4 1.4 18.3 11.5 13.3 1.5 17.9 9.5 218 5 223 305 -5.3 0 -5.1 -5.6 02/18/2006 23:50:00 15 1 17.2 12.6 14.2 1 16.8 11.5 215 4 211 305 -5.6 0 -5.3 -5.8 02/19/2006 00:00:00 14.4 1.1 17.2 11.8 13.5 1.1 16.8 10.7 218 5 224 305 -5.6 0 -5.1 -5.8 02/19/2006 00:10:00 14.7 1 17.2 11.8 13.7 1.1 16.8 10.3 213 3 212 305 -5.9 0.1 -5.1 -6.2 02/19/2006 00:20:00 15.1 1 17.2 12.6 14.2 1.1 17.2 10.7 213 4 213 305 -6.1 0 -5.6 -6.2 02/19/2006 00:30:00 15.3 1.1 19.1 11.5 14.3 1.2 17.9 10.7 213 5 218 305 -6.1 0 -6 -6.2 02/19/2006 00:40:00 14.9 1.1 18.3 12.6 14 1.2 17.2 10.7 214 4 218 305 -6 0 -5.8 -6 02/19/2006 00:50:00 14.8 1 17.9 12.2 13.8 1.1 17.2 10.7 213 4 213 305 -5.8 0 -5.6 -6 02/19/2006 01:00:00 14.8 1.1 17.9 11.8 13.9 1.3 17.2 10.7 213 4 222 305 -5.5 0.1 -4.9 -5.8 02/19/2006 01:10:00 14 1.2 17.2 9.9 12.9 1.4 16.4 9.9 209 5 208 305 -5.3 0 -4.7 -5.6 02/19/2006 01:20:00 14.6 1.1 17.6 10.3 13.7 1.2 16.4 10.3 206 4 210 305 -5.4 0 -4.9 -5.6 02/19/2006 01:30:00 14.9 1 17.9 11.5 13.8 1.1 17.2 11.1 206 4 205 305 -5.2 0 -5.1 -5.6 02/19/2006 01:40:00 15 1.1 17.9 11.1 14.2 1.3 16.8 9.9 205 4 208 305 -5.2 0 -4.5 -5.3 02/19/2006 01:50:00 15 1.1 17.6 11.8 14.1 1.2 16.8 10.3 204 4 202 305 -5.4 0 -5.1 -5.6 02/19/2006 02:00:00 15.1 1 17.6 12.6 14.4 1.1 17.2 11.5 203 4 203 305 -5.4 0.1 -4.9 -5.6 02/19/2006 02:10:00 13.4 1.1 16.8 9.1 12.7 1.1 16.1 9.9 205 4 200 305 -5.5 0 -4.9 -5.6 02/19/2006 02:20:00 13.9 1 16.8 10.3 13.1 1.1 15.6 9.9 205 4 211 305 -5.3 0.1 -4.9 -5.6 02/19/2006 02:30:00 14.9 1 17.6 11.8 13.8 1.2 17.2 9.9 206 4 206 305 -4.9 0 -4.7 -5.1 02/19/2006 02:40:00 15.1 1.1 17.6 12.2 14.3 1.2 17.2 10.7 204 3 204 305 -4.7 0 -4.5 -4.9 02/19/2006 02:50:00 15.6 1.2 19.1 12.6 14.9 1.2 18.3 11.8 203 3 205 305 -4.7 0 -4.5 -4.9 02/19/2006 03:00:00 15.5 1.1 18.3 12.6 14.8 1.2 17.6 11.1 200 4 200 305 -4.8 0 -4.7 -4.9 02/19/2006 03:10:00 15.3 1 18.3 13 14.7 1 17.2 10.7 199 3 200 305 -4.9 0 -4.7 -5.1 02/19/2006 03:20:00 14.7 1 17.6 12.2 14.1 1 17.6 11.1 201 3 205 305 -4.8 0 -4.7 -4.9 02/19/2006 03:30:00 15 1.1 17.9 11.5 14.3 1.2 17.9 9.9 200 4 194 305 -4.6 0 -4.5 -4.7 02/19/2006 03:40:00 14.9 1 18.3 12.2 14.4 1.1 17.2 11.5 199 4 205 305 -4.5 0 -4.5 -4.7 02/19/2006 03:50:00 14.4 1 16.8 11.8 13.8 1 16.4 10.7 200 4 203 305 -4.5 0 -4.5 -4.7 02/19/2006 04:00:00 14.4 0.8 17.2 11.8 13.8 0.9 16.4 10.7 201 4 201 305 -4.4 0 -4.5 -4.7 02/19/2006 04:10:00 14 0.9 16.8 11.1 13.4 1 15.6 10.3 202 4 208 305 -4.4 0 -4.2 -4.7 02/19/2006 04:20:00 14.7 0.9 17.6 12.6 14 1 16.8 11.1 201 3 198 305 -4.3 0 -4 -4.5 02/19/2006 04:30:00 14.7 1 17.6 11.8 14.2 1 17.2 11.8 199 3 198 305 -4.3 0 -4 -4.5 02/19/2006 04:40:00 13.4 0.8 15.6 11.5 12.8 0.9 15.3 10.7 201 4 202 305 -4.4 0 -4 -4.5 02/19/2006 04:50:00 14.3 1 16.8 11.8 13.7 1 16.4 11.5 200 4 196 305 -4.2 0 -4 -4.5 02/19/2006 05:00:00 13.8 0.9 16.8 11.5 13.3 1 16.4 10.3 198 4 203 305 -4.1 0 -3.8 -4.2 02/19/2006 05:10:00 13.7 0.9 15.6 11.5 13.2 1 15.6 10.3 194 3 191 305 -4.1 0.1 -3.8 -4.5 02/19/2006 05:20:00 14.3 1 16.8 11.5 13.8 1.1 16.4 11.1 195 4 197 305 -4.4 0 -4 -4.5 02/19/2006 05:30:00 14.5 0.9 17.2 11.8 13.8 1 16.8 11.5 196 4 197 305 -4.2 0 -4 -4.5 02/19/2006 05:40:00 14.1 1.1 17.2 11.8 13.5 1.1 17.2 10.7 196 4 197 305 -3.9 0.1 -3.6 -4.2 02/19/2006 05:50:00 13.9 1.1 16.4 11.5 13.4 1.2 16.1 10.7 193 3 194 305 -3.7 0 -3.6 -3.8 02/19/2006 06:00:00 13.8 0.9 16.1 11.5 13.2 1 16.1 8.8 193 3 192 305 -3.4 0 -3.3 -3.8 02/19/2006 06:10:00 12.6 1.3 15.6 9.1 12.1 1.1 15.3 9.5 189 4 197 305 -3.4 0.1 -3.3 -3.8 02/19/2006 06:20:00 12 0.8 14.5 9.9 11.8 0.8 14.1 9.9 185 3 189 305 -3.8 0 -3.3 -4 02/19/2006 06:30:00 11.8 0.8 13.7 9.1 11.6 0.8 13.7 8.8 185 3 188 305 -3.7 0 -3.6 -3.8 02/19/2006 06:40:00 11 1.1 13.7 7.2 11.1 0.9 13.7 8.8 183 3 182 305 -3.7 0 -3.1 -3.8 02/19/2006 06:50:00 9.7 2.1 14.1 4.2 11.8 1.2 14.9 8.8 177 7 179 305 -3.5 0 -3.1 -3.8 02/19/2006 07:00:00 10.6 1.7 15.3 6.5 13.1 1.2 16.8 9.1 175 6 187 305 -3.3 0 -3.1 -3.6 02/19/2006 07:10:00 9.7 1.5 14.9 6.1 12.9 1 16.1 9.9 172 7 182 305 -3.3 0 -3.1 -3.3 02/19/2006 07:20:00 9.6 1.3 13.3 6.8 13.8 1.3 16.8 9.9 168 7 189 305 -3.2 0 -2.9 -3.3 02/19/2006 07:30:00 9.4 1.1 13 6.5 13.9 1.3 16.4 10.7 165 4 172 305 -3.3 0 -3.1 -3.3 02/19/2006 07:40:00 10.2 1.1 13 7.2 14.4 1 17.6 10.7 166 5 176 305 -3.3 0 -3.1 -3.3 02/19/2006 07:50:00 10 1.4 15.6 6.1 13.8 1.3 16.8 9.9 168 6 172 305 -3.1 0 -2.4 -3.3 02/19/2006 08:00:00 11.2 1.7 15.3 6.5 12.7 1.2 16.1 9.9 178 7 190 305 -3.1 0 -2.9 -3.3 02/19/2006 08:10:00 13.6 1.1 16.4 10.3 13.5 1.1 16.1 9.5 185 4 186 305 -3.1 0 -2.9 -3.3 02/19/2006 08:20:00 14.1 1.1 17.6 11.5 13.5 1.2 16.4 9.5 193 5 194 305 -2.9 0.1 -2.7 -3.1 02/19/2006 08:30:00 14.1 1.4 17.6 10.7 13.5 1.5 16.8 9.1 197 4 198 305 -2.7 0 -2.7 -2.9 02/19/2006 08:40:00 13.4 0.9 15.6 11.1 12.8 1 15.3 8.8 198 4 195 305 -2.9 0 -2.7 -3.1 02/19/2006 08:50:00 13 0.9 15.6 10.7 12.3 1 14.9 8.4 197 4 195 305 -3.1 0.1 -2.9 -3.3 02/19/2006 09:00:00 13.1 0.8 15.3 11.1 12.6 0.8 14.9 9.9 196 4 197 305 -3.2 0 -3.1 -3.3 02/19/2006 09:10:00 13.4 1 15.6 10.7 12.9 1.1 15.6 9.9 197 3 194 305 -3.2 0 -2.7 -3.3 02/19/2006 09:20:00 13.9 1 16.8 11.1 13.3 1.1 16.4 9.9 195 3 200 305 -3.3 0 -3.1 -3.3 02/19/2006 09:30:00 13.1 1 16.1 10.7 12.5 1.1 15.3 9.9 195 4 200 305 -3.6 0 -3.1 -3.8 02/19/2006 09:40:00 12.8 0.9 15.3 10.7 12.1 1 14.5 8.8 193 4 194 305 -3.9 0 -3.6 -4 02/19/2006 09:50:00 13.6 1.1 16.8 10.3 12.8 1.2 15.6 8.8 192 4 190 305 -3.9 0 -3.8 -4 02/19/2006 10:00:00 13.4 1 16.8 11.1 12.7 1.1 16.1 9.9 190 4 200 305 -4.2 0.1 -4 -4.5 02/19/2006 10:10:00 13.5 1 15.6 11.1 12.7 1.1 15.6 9.1 191 4 192 305 -4.4 0.1 -4 -4.7 02/19/2006 10:20:00 13.6 0.9 16.1 11.8 12.8 1 15.6 10.3 192 4 194 305 -4.1 0 -3.8 -4.2 02/19/2006 10:30:00 13.8 1.1 17.2 10.7 13.1 1.2 16.4 9.5 193 4 192 305 -4.1 0.1 -3.8 -4.5 02/19/2006 10:40:00 15.7 1 17.9 13 15 1 17.6 11.5 196 3 198 305 -3.5 0 -3.3 -3.8 02/19/2006 10:50:00 14.3 1 17.9 11.5 13.7 1 16.4 10.7 195 4 202 305 -3.6 0 -3.3 -3.8 02/19/2006 11:00:00 14.6 1.3 18.7 11.8 13.9 1.3 17.9 10.7 196 5 194 305 -3.5 0 -3.3 -3.8 02/19/2006 11:10:00 14.7 1.1 18.7 11.8 14.1 1.3 17.2 10.7 189 3 194 305 -3.4 0 -3.1 -3.8 02/19/2006 11:20:00 14.3 0.8 16.1 12.2 13.8 1 16.1 11.1 195 4 191 305 -3.3 0 -3.1 -3.6 02/19/2006 11:30:00 14.3 1.1 17.2 11.1 13.6 1.1 16.8 10.3 199 4 204 305 -3.2 0 -2.7 -3.3 02/19/2006 11:40:00 13.8 1.1 17.2 11.5 13.2 1 16.1 9.9 202 5 201 305 -3.2 0 -3.1 -3.3 02/19/2006 11:50:00 13 1.4 17.2 9.9 12.3 1.4 16.4 8.8 205 5 203 305 -3.3 0 -3.1 -3.3 02/19/2006 12:00:00 13.9 1.2 16.8 10.7 13.1 1.3 16.1 8.8 204 5 214 305 -3.3 0 -3.3 -3.3 02/19/2006 12:10:00 13.5 0.9 15.6 11.1 12.8 1 14.9 9.5 204 4 206 305 -3.4 0 -2.9 -3.6 02/19/2006 12:20:00 14.1 1 16.8 11.8 13.6 1 15.6 9.9 202 4 208 305 -3.5 0 -3.3 -3.6 02/19/2006 12:30:00 13.8 0.9 16.8 11.1 13.3 1 15.6 10.3 203 4 203 305 -3.5 0 -3.3 -3.6 02/19/2006 12:40:00 13.4 1.1 16.1 10.3 12.8 1.1 15.6 9.5 204 4 198 305 -3.5 0 -2.9 -3.8 02/19/2006 12:50:00 11.4 1.2 14.9 8.8 10.7 1.2 13.7 8 210 5 212 305 -3.4 0 -3.1 -3.6 02/19/2006 13:00:00 10.2 1 13 7.6 9.7 1.1 12.6 6.8 215 5 210 305 -3.5 0 -2.9 -3.6 02/19/2006 13:10:00 9 1 11.5 6.5 8.5 1 11.5 6.5 214 5 210 305 -3.6 0 -3.3 -3.8 02/19/2006 13:20:00 7.1 0.7 8.8 5.3 6.5 0.8 8.4 4.6 224 6 221 305 -3.8 0 -3.6 -3.8 02/19/2006 13:30:00 6.4 0.7 8 4.2 6 0.7 7.6 3.8 222 5 215 305 -4 0 -3.8 -4 02/19/2006 13:40:00 6.7 1 9.1 4.6 5.9 1 8.8 3.4 243 13 259 305 -4 0 -3.6 -4.2 02/19/2006 13:50:00 7.2 0.8 9.5 5.3 5.9 0.9 9.1 3.4 262 7 259 305 -4.2 0.1 -3.6 -4.5 02/19/2006 14:00:00 7.1 0.9 8.8 4.6 5.7 0.8 8 2.6 267 7 273 305 -4.4 0 -4 -4.7 02/19/2006 14:10:00 6.2 0.9 8.8 3.4 4.9 0.8 7.2 2.6 268 8 270 305 -4.5 0 -4 -4.7 02/19/2006 14:20:00 7.6 0.9 9.9 4.9 6.2 1 9.5 3.4 264 9 263 305 -4.7 0 -4.5 -4.9 02/19/2006 14:30:00 8.2 1 10.7 4.9 6.7 1 9.1 3.8 260 7 261 305 -4.7 0 -4.5 -4.9 02/19/2006 14:40:00 8.9 1.1 11.5 5.7 7.9 1.3 11.5 4.9 253 7 259 305 -4.4 0.1 -4 -4.7 02/19/2006 14:50:00 10.8 1.4 14.5 7.2 9.7 1.5 13.7 6.1 249 7 250 305 -4.5 0.1 -4 -4.9 02/19/2006 15:00:00 10 1.3 13.3 6.1 9 1.5 12.6 4.9 251 7 254 305 -5.1 0.1 -4.7 -5.6 02/19/2006 15:10:00 9.6 1.4 12.6 5.3 8.3 1.6 12.2 4.2 255 6 256 305 -5.5 0 -5.1 -5.8 02/19/2006 15:20:00 8 1 10.3 4.6 6.7 1.1 9.9 4.2 256 7 254 305 -5.5 0 -4.9 -5.6 02/19/2006 15:30:00 8.4 1 10.7 5.7 7.6 1.1 10.7 4.9 251 6 251 305 -5.5 0 -5.3 -5.6 02/19/2006 15:40:00 8.2 0.8 10.7 6.1 7.6 0.9 9.9 5.3 242 5 245 305 -5.5 0 -4.9 -5.6 02/19/2006 15:50:00 8 0.8 9.5 6.1 7.3 0.9 9.1 5.3 236 5 242 305 -5.5 0 -4.9 -5.6 02/19/2006 16:00:00 8.1 0.8 9.9 6.1 7.3 0.9 9.9 4.9 232 5 242 305 -5.6 0 -5.6 -5.8 02/19/2006 16:10:00 7.1 0.8 9.1 5.3 6.4 0.8 8.8 4.6 230 5 230 305 -5.6 0 -5.6 -5.8 02/19/2006 16:20:00 7.7 0.7 9.5 6.1 7.1 0.8 9.5 4.9 227 5 230 305 -5.4 0.1 -5.1 -5.8 02/19/2006 16:30:00 7 0.6 8.4 5.3 6.3 0.7 8 4.6 224 5 221 305 -5.1 0 -4.9 -5.1 02/19/2006 16:40:00 7.5 0.6 9.1 6.1 7 0.7 8.4 4.9 217 5 209 305 -5.2 0.1 -4.9 -5.6 02/19/2006 16:50:00 8 0.9 10.3 5.7 7.3 1 10.3 4.9 210 5 211 305 -5.6 0.1 -5.3 -6 02/19/2006 17:00:00 8.4 0.7 10.3 6.1 7.9 0.8 9.9 5.3 207 4 212 305 -6 0 -5.8 -6.2 02/19/2006 17:10:00 9.1 0.6 11.5 7.6 8.7 0.7 10.7 6.8 204 3 204 305 -5.9 0 -5.6 -6 02/19/2006 17:20:00 9.8 0.7 11.8 8 9.3 0.7 11.5 7.2 204 4 210 305 -5.7 0 -5.6 -5.8 02/19/2006 17:30:00 10 0.5 11.5 8.8 9.6 0.6 11.5 7.2 200 3 203 305 -5.7 0 -5.6 -5.8 02/19/2006 17:40:00 10 0.7 12.6 8 9.7 0.6 11.5 8 199 4 191 305 -5.5 0.1 -5.1 -5.8 02/19/2006 17:50:00 10.5 0.7 12.2 8.4 10.2 0.7 11.8 8.4 201 4 210 305 -5.5 0 -5.1 -5.8 02/19/2006 18:00:00 10.4 0.7 12.6 8.8 10.1 0.6 11.8 8.4 201 3 196 305 -5.7 0.1 -5.6 -5.8 02/19/2006 18:10:00 11.3 0.9 13.3 9.5 10.9 0.8 13 8.4 200 4 202 305 -5.7 0 -5.3 -5.8 02/19/2006 18:20:00 11.8 0.7 13.7 9.9 11.3 0.8 13.3 8.8 202 3 194 305 -5.7 0 -5.6 -5.8 02/19/2006 18:30:00 11.8 0.8 13.7 9.5 11.3 0.8 13.3 9.5 201 3 197 305 -5.7 0 -5.6 -6 02/19/2006 18:40:00 12.1 0.8 14.1 9.9 11.6 0.8 13.3 9.5 201 4 200 305 -5.7 0 -5.6 -5.8 02/19/2006 18:50:00 12.2 0.7 14.5 10.3 11.7 0.7 13.3 8.8 203 4 208 305 -5.7 0 -5.6 -5.8 02/19/2006 19:00:00 12.3 0.9 14.9 10.7 11.7 0.9 14.1 8.8 203 4 203 305 -5.8 0 -5.6 -6 02/19/2006 19:10:00 13.3 1 15.6 11.5 12.8 1 15.3 9.9 204 3 205 305 -5.7 0 -5.6 -6 02/19/2006 19:20:00 13.7 0.9 16.1 11.8 13.1 0.9 15.3 10.7 205 4 208 305 -5.8 0 -5.6 -5.8 02/19/2006 19:30:00 13.7 0.9 16.4 11.5 13 0.9 16.4 10.7 204 3 198 305 -5.8 0 -5.8 -6 02/19/2006 19:40:00 14.1 0.9 16.8 11.8 13.3 0.9 15.6 10.7 205 4 201 305 -5.9 0 -5.8 -6 02/19/2006 19:50:00 14.4 1 17.9 12.2 13.6 1 16.4 11.1 204 4 203 305 -6.2 0 -6 -6.4 02/19/2006 20:00:00 14.6 0.8 16.8 12.2 13.9 0.8 16.1 11.1 205 4 197 305 -6.3 0.1 -5.8 -6.7 02/19/2006 20:10:00 14.3 1 16.8 10.7 13.5 1 16.1 11.1 205 4 208 305 -6.5 0 -6 -6.7 02/19/2006 20:20:00 13.7 1 16.4 10.3 12.6 1.2 16.1 9.5 209 5 196 305 -6.7 0 -6.2 -6.9 02/19/2006 20:30:00 12.4 1.3 15.3 8.8 11.7 1.5 15.3 7.6 207 4 205 305 -6.8 0 -6.7 -6.9 02/19/2006 20:40:00 12.8 1.3 16.1 9.5 11.8 1.5 15.3 8 208 5 210 305 -6.7 0 -6.7 -6.9 02/19/2006 20:50:00 13.2 1.1 16.4 10.3 12.3 1.3 15.3 8.8 208 4 208 305 -6.6 0 -6.7 -6.9 02/19/2006 21:00:00 13.1 1 15.6 9.9 12.1 1.2 15.3 8.4 208 5 211 305 -6.7 0 -6.7 -6.9 02/19/2006 21:10:00 12.8 1.1 15.6 9.5 11.7 1.3 14.5 8.4 209 5 214 305 -6.9 0.1 -6.7 -7.1 02/19/2006 21:20:00 12.6 1.2 14.9 9.1 11.4 1.3 14.1 8 210 5 211 305 -7 0 -6.9 -7.1 02/19/2006 21:30:00 12 1.4 16.1 7.6 11 1.5 15.3 8 209 5 208 305 -6.9 0 -6.7 -7.1 02/19/2006 21:40:00 13.8 1 16.1 10.3 13.1 1.1 16.1 10.3 208 4 204 305 -6.8 0 -6.7 -6.9 02/19/2006 21:50:00 13.2 1 16.4 10.7 12.4 1 14.9 9.5 208 5 211 305 -6.9 0 -6.9 -7.1 02/19/2006 22:00:00 12.5 1 15.3 9.9 11.5 1.1 14.5 8.4 211 5 213 305 -6.8 0 -6.7 -6.9 02/19/2006 22:10:00 12.1 1 14.9 9.1 11.3 1.1 13.7 8.4 207 4 207 305 -6.8 0 -6.7 -7.1 02/19/2006 22:20:00 12.3 0.8 15.3 9.5 11.6 0.9 14.1 8.8 208 4 210 305 -6.8 0 -6.7 -6.9 02/19/2006 22:30:00 12.3 0.8 14.5 9.5 11.6 0.9 14.1 8 206 4 208 305 -6.9 0.1 -6.7 -7.1 02/19/2006 22:40:00 12.1 1.3 15.3 7.6 11.4 1.3 14.5 7.6 207 5 203 305 -7.1 0 -6.9 -7.3 02/19/2006 22:50:00 12.3 1.1 15.3 9.5 11.6 1.1 14.5 8.8 208 4 210 305 -7 0 -6.7 -7.1 02/19/2006 23:00:00 13.4 1 16.4 10.3 12.7 1 15.3 9.5 206 4 203 305 -6.7 0 -6.7 -6.9 02/19/2006 23:10:00 13 1.1 16.1 8 12.4 1.1 15.3 9.1 207 5 208 305 -6.6 0 -6.4 -6.7 02/19/2006 23:20:00 13.1 1.2 15.6 9.9 12.2 1.2 14.9 8.8 208 5 210 305 -6.7 0 -6.7 -6.9 02/19/2006 23:30:00 13.2 1.2 17.2 9.9 12.3 1.3 15.6 9.1 210 5 216 305 -6.8 0 -6.7 -6.9 02/19/2006 23:40:00 13 1.2 16.8 9.1 12 1.2 15.3 8.4 210 5 213 305 -6.9 0 -6.7 -7.1 02/19/2006 23:50:00 12.6 1.3 16.4 9.5 11.8 1.3 16.1 8 215 6 218 305 -6.8 0.1 -6.7 -6.9 02/20/2006 00:00:00 13.3 1.4 16.4 9.1 12.3 1.4 15.3 8.4 221 5 217 305 -6.5 0 -6.2 -6.7 02/20/2006 00:10:00 12.2 1.1 14.9 9.5 11.3 1.3 14.5 8.4 224 5 232 305 -6.6 0 -6.4 -6.7 02/20/2006 00:20:00 12.2 1.3 16.1 9.1 11.4 1.3 14.5 8.4 229 5 232 305 -6.5 0 -6.4 -6.7 02/20/2006 00:30:00 11.7 1.1 14.5 8.8 10.9 1.2 14.1 8 231 5 232 305 -6.6 0 -6.4 -6.9 02/20/2006 00:40:00 10.6 1 13 8.4 9.8 1.1 13 7.2 230 5 229 305 -6.8 0 -6.7 -6.9 02/20/2006 00:50:00 10.6 1.2 13.7 7.2 9.8 1.1 12.6 6.8 233 5 234 305 -6.9 0 -6.7 -6.9 02/20/2006 01:00:00 10.5 1.4 13.7 6.1 9.3 1.7 13 5.3 248 13 236 305 -6.9 0 -6.7 -7.3 02/20/2006 01:10:00 8.6 1.3 11.1 4.9 6.7 1.2 9.1 3.4 266 7 267 305 -7.4 0.1 -7.1 -7.7 02/20/2006 01:20:00 8.9 1.1 11.5 5.7 7 1.2 9.9 3.8 265 7 258 305 -7.6 0 -7.3 -7.7 02/20/2006 01:30:00 9.2 1.2 11.5 6.1 7.4 1.1 10.3 4.6 268 7 264 305 -7.8 0.1 -7.7 -8.2 02/20/2006 01:40:00 8.3 1.1 11.1 5.7 6.7 1 9.1 3.8 270 7 273 305 -8.2 0 -8.2 -8.4 02/20/2006 01:50:00 9.1 1.3 11.8 5.7 7.5 1.3 11.1 3.8 259 7 261 305 -8.3 0 -8.2 -8.6 02/20/2006 02:00:00 9.2 1 11.1 6.5 8.1 1.2 11.1 5.3 253 6 256 305 -8.5 0 -8.4 -8.6 02/20/2006 02:10:00 10 0.9 12.2 7.6 9.1 1.1 11.8 5.7 251 5 251 305 -8.6 0 -8.4 -8.8 02/20/2006 02:20:00 9.2 0.9 11.5 6.8 8.4 0.9 11.1 5.7 240 6 231 305 -8.9 0.2 -8.4 -9.2 02/20/2006 02:30:00 9.7 0.9 11.8 6.5 8.9 1 11.5 6.1 239 5 242 305 -9.4 0 -9.2 -9.6 02/20/2006 02:40:00 10.2 1 12.6 7.6 9.4 1 11.8 6.1 241 6 241 305 -9.5 0 -9.4 -9.6 02/20/2006 02:50:00 10.2 1 12.6 7.2 9.5 1 12.2 6.8 240 6 241 305 -9.5 0 -9.2 -9.6 02/20/2006 03:00:00 10.3 1 13 7.2 9.5 1.3 12.6 5.7 244 5 254 305 -9.4 0 -9.2 -9.6 02/20/2006 03:10:00 8.9 1.1 11.5 6.1 8 1.2 11.1 4.9 243 6 242 305 -9.6 0 -9.4 -9.8 02/20/2006 03:20:00 10.8 1 13 8 9.9 1.1 12.6 6.5 244 5 248 305 -9.7 0 -9.6 -9.8 02/20/2006 03:30:00 9.9 1.2 12.2 6.8 8.9 1.2 11.8 6.5 245 6 246 305 -9.8 0 -9.6 -10 02/20/2006 03:40:00 9.6 0.9 11.5 6.8 8.7 0.9 11.1 6.1 243 5 246 305 -10.1 0 -9.8 -10.2 02/20/2006 03:50:00 8.4 1.5 11.5 4.2 7.6 1.5 10.7 4.2 249 7 245 305 -10.3 0 -10 -10.4 02/20/2006 04:00:00 9.8 1 12.2 7.2 8.6 1.2 11.8 5.3 253 5 254 305 -10.4 0 -10.4 -10.7 02/20/2006 04:10:00 8.7 1.3 11.5 4.6 7.7 1.3 10.7 4.6 251 7 255 305 -10.5 0 -10.4 -10.9 02/20/2006 04:20:00 7.7 1 9.9 4.9 6.9 0.9 9.1 4.6 243 6 241 305 -10.9 0 -10.7 -11.3 02/20/2006 04:30:00 7.4 0.8 9.5 4.6 6.7 0.8 9.1 4.2 243 6 250 305 -11.1 0 -10.9 -11.3 02/20/2006 04:40:00 7 1.2 9.9 3.8 6.3 1.1 9.5 3.4 250 8 255 305 -11.2 0 -11.1 -11.5 02/20/2006 04:50:00 8.6 1.2 11.5 5.7 7.2 1.2 9.9 3.4 257 7 258 305 -11.4 0.1 -11.1 -11.7 02/20/2006 05:00:00 9.5 1 12.2 7.2 8 1.1 11.1 4.6 256 6 263 305 -11.6 0 -11.5 -11.9 02/20/2006 05:10:00 9.7 0.9 12.2 6.8 8.2 1.1 11.5 4.9 256 6 263 305 -11.8 0 -11.7 -11.9 02/20/2006 05:20:00 9.6 1 11.8 6.8 8.3 1.3 11.5 4.6 255 6 253 305 -11.8 0 -11.7 -12.1 02/20/2006 05:30:00 9.3 1 11.8 6.8 8 1.3 11.1 4.6 256 6 258 305 -11.9 0 -11.7 -12.1 02/20/2006 05:40:00 8.1 1 10.7 5.7 6.9 1.1 9.5 4.2 256 6 258 305 -12.1 0 -11.7 -12.3 02/20/2006 05:50:00 7.6 1 10.7 4.6 6.3 1 8.8 3.8 258 6 259 305 -12.2 0 -12.1 -12.5 02/20/2006 06:00:00 8.2 1 9.9 4.2 7 1.1 9.5 4.2 257 6 258 305 -12.2 0 -12.1 -12.5 02/20/2006 06:10:00 8.1 1 10.3 5.3 6.7 1.1 9.9 3.8 257 6 258 305 -12.3 0 -12.1 -12.5 02/20/2006 06:20:00 8 0.8 9.9 5.7 6.6 1 9.1 4.2 260 6 259 305 -12.2 0 -12.1 -12.5 02/20/2006 06:30:00 6.8 0.9 9.1 4.9 5.5 0.9 8 3 261 7 261 305 -12.2 0 -11.9 -12.5 02/20/2006 06:40:00 7.1 0.8 8.8 4.6 6 0.9 8.8 3.8 256 6 262 305 -12.3 0 -12.1 -12.5 02/20/2006 06:50:00 7.8 1 10.3 4.9 6.5 1.1 9.1 4.2 257 7 261 305 -12.4 0 -12.1 -12.5 02/20/2006 07:00:00 7.9 0.9 9.9 5.3 6.5 1 9.1 3.8 257 6 256 305 -12.5 0 -12.3 -12.5 02/20/2006 07:10:00 7 1.2 10.3 3.8 5.6 1.1 8.4 3.4 264 9 258 305 -12.4 0.1 -12.1 -12.5 02/20/2006 07:20:00 7.5 1 9.5 4.2 6.1 1 8.8 3.4 267 8 276 305 -12.2 0 -12.1 -12.5 02/20/2006 07:30:00 7.7 1.1 10.3 3.8 6.2 1.1 8.8 3.4 262 7 269 305 -12.3 0 -12.1 -12.5 02/20/2006 07:40:00 8.4 1.3 11.1 4.6 6.8 1.2 9.9 3 265 7 261 305 -12.3 0 -12.3 -12.5 02/20/2006 07:50:00 7.2 1.5 9.9 4.2 5.7 1.3 8.8 3 261 9 273 305 -12.4 0 -12.1 -12.7 02/20/2006 08:00:00 6.5 0.8 8.4 3.8 5.5 0.9 7.6 3.4 254 7 266 305 -12.6 0 -12.5 -12.7 02/20/2006 08:10:00 7.8 1.7 11.8 4.6 6.4 1.4 10.7 3.4 266 11 268 305 -12.7 0 -12.5 -12.9 02/20/2006 08:20:00 8.6 1.2 11.1 5.7 7.3 1.3 10.7 4.6 278 7 280 305 -13.3 0.1 -12.9 -13.5 02/20/2006 08:30:00 6.8 0.8 8.8 4.6 5.4 0.9 8 3.4 271 7 269 305 -13.5 0 -13.1 -13.5 02/20/2006 08:40:00 6.5 1 9.1 4.2 5.1 1 7.6 2.3 268 7 276 305 -13.4 0 -13.3 -13.5 02/20/2006 08:50:00 7.1 0.9 9.9 5.3 5.6 0.9 8 3.4 261 7 268 305 -13.4 0 -12.9 -13.5 02/20/2006 09:00:00 7.9 1 10.7 5.7 6.4 1 9.1 3.8 261 6 262 305 -13.5 0.1 -12.9 -13.7 02/20/2006 09:10:00 8.2 0.7 9.9 6.5 6.8 0.9 8.8 4.2 259 5 256 305 -13.7 0 -12.9 -13.9 02/20/2006 09:20:00 8.1 0.9 9.9 5.7 6.8 0.9 9.1 4.6 258 6 259 305 -13.8 0 -13.7 -14.1 02/20/2006 09:30:00 8 1 10.3 5.3 7 1.1 9.9 3.8 249 8 256 305 -14 0.1 -13.3 -14.3 02/20/2006 09:40:00 9 0.8 11.1 6.8 8.2 1 10.3 5.7 248 5 254 305 -14.4 0.1 -13.7 -14.6 02/20/2006 09:50:00 7.9 1 10.3 5.3 7.1 1 9.9 4.6 249 6 254 305 -14.7 0 -14.3 -14.8 02/20/2006 10:00:00 8.6 0.8 10.7 6.5 7.7 1 10.3 4.9 251 7 252 305 -14.7 0 -14.3 -14.8 02/20/2006 10:10:00 9.4 1.3 11.8 5.7 7.5 1.3 10.3 4.2 263 7 266 305 -14.7 0 -14.3 -14.8 02/20/2006 10:20:00 9.2 1.2 11.8 6.1 7.5 1.2 10.7 4.2 268 7 268 305 -14.7 0 -14.3 -14.8 02/20/2006 10:30:00 8.8 1.1 11.5 5.3 7.2 1.1 10.3 4.6 271 7 275 305 -14.8 0 -14.3 -15 02/20/2006 10:40:00 9.5 1.3 12.2 6.1 7.9 1.5 11.5 3.8 271 7 275 305 -14.9 0 -14.4 -15 02/20/2006 10:50:00 9.1 1.2 12.2 5.7 7.3 1.2 10.7 4.6 268 7 266 305 -15 0 -14.4 -15 02/20/2006 11:00:00 8.6 1.3 11.5 5.7 7 1.3 9.9 4.2 268 8 253 305 -15.1 0 -15 -15 02/20/2006 11:10:00 8.3 1.6 11.8 4.6 6.6 1.6 11.1 3.4 267 9 261 305 -15.1 0 -14.6 -15 02/20/2006 11:20:00 8.2 1.2 11.5 4.9 6.8 1.4 10.3 3.4 273 7 272 305 -15.1 0 -15 -15.2 02/20/2006 11:30:00 9.7 1.4 13 6.1 8.1 1.3 11.8 4.6 273 7 269 305 -15.3 0 -15 -15.4 02/20/2006 11:40:00 10.5 1.3 13.3 7.2 9 1.3 12.2 5.3 275 7 270 305 -15.4 0 -15.2 -15.6 02/20/2006 11:50:00 10.5 1.1 13.3 7.6 8.9 1.2 12.6 6.1 275 7 277 305 -15.5 0 -15.2 -15.6 02/20/2006 12:00:00 9.8 1.3 12.6 6.1 8.3 1.4 11.8 4.2 273 8 278 305 -15.4 0 -15.2 -15.6 02/20/2006 12:10:00 9.5 1.3 12.2 5.7 7.8 1.3 11.1 4.2 272 8 265 305 -15.3 0 -15 -15.6 02/20/2006 12:20:00 8.8 1.3 11.8 5.3 7.4 1.4 10.7 4.2 275 8 260 305 -15.3 0 -15 -15.4 02/20/2006 12:30:00 11.2 1.5 14.5 7.2 9.6 1.5 13.3 6.1 275 7 275 305 -15.2 0 -15 -15.2 02/20/2006 12:40:00 11.2 1.3 15.3 8.4 9.7 1.4 13 6.5 275 8 272 305 -15.2 0 -15 -15.2 02/20/2006 12:50:00 11.7 1.5 14.5 7.2 9.8 1.6 13 5.3 275 7 284 305 -15.1 0 -14.8 -15.2 02/20/2006 13:00:00 12 1.3 15.3 7.2 10.3 1.6 14.5 6.1 273 7 279 305 -15.1 0.1 -14.8 -15.2 02/20/2006 13:10:00 12.2 1.2 14.5 8.8 10.2 1.4 13.7 6.1 273 7 274 305 -15.1 0 -15 -15.2 02/20/2006 13:20:00 11.3 1.8 14.1 6.1 9.2 1.7 13 4.9 270 7 268 305 -15.1 0.1 -14.8 -15.4 02/20/2006 13:30:00 11.7 1.5 14.5 7.2 9.4 1.5 13.3 5.3 270 7 269 305 -15 0 -14.8 -15 02/20/2006 13:40:00 11.5 1.5 14.9 6.5 9.2 1.5 13 4.9 267 6 264 305 -15 0 -14.8 -15 02/20/2006 13:50:00 10.8 1.4 14.1 7.6 9 1.7 13.3 5.7 269 8 279 305 -15 0 -14.8 -15 02/20/2006 14:00:00 11.1 1.3 14.1 8 9.5 1.3 13.3 6.5 275 7 283 305 -15 0 -14.8 -15 02/20/2006 14:10:00 11 1.3 13.7 7.2 9.5 1.5 12.6 5.7 273 6 269 305 -15 0 -14.8 -15 02/20/2006 14:20:00 9.8 1.4 13.3 6.1 7.9 1.4 12.2 4.2 268 9 259 305 -15 0 -14.8 -15 02/20/2006 14:30:00 11.1 1.2 13.3 7.2 9.2 1.3 12.6 5.3 263 6 256 305 -14.9 0 -14.6 -15 02/20/2006 14:40:00 11.4 1.3 14.1 7.2 9.3 1.6 13.3 5.7 266 7 269 305 -14.8 0 -14.6 -15 02/20/2006 14:50:00 11.2 1.6 14.9 6.5 9.1 1.5 12.2 4.9 264 6 263 305 -15 0.1 -14.6 -15.2 02/20/2006 15:00:00 10.6 1 12.6 8 9.2 1.2 12.6 5.3 259 7 268 305 -15 0 -14.6 -15 02/20/2006 15:10:00 11.1 1.7 14.5 7.2 9.2 1.7 14.1 5.3 261 7 251 305 -14.7 0 -14.4 -14.8 02/20/2006 15:20:00 10.6 1.5 14.1 6.8 8.8 1.3 13.3 5.7 259 7 266 305 -14.8 0.1 -14.4 -15 02/20/2006 15:30:00 10.6 1.5 13.3 5.7 8.8 1.4 13 4.6 265 7 262 305 -14.7 0 -14.6 -15 02/20/2006 15:40:00 10 1.4 13.7 6.1 8.3 1.5 12.2 4.6 261 8 262 305 -14.8 0 -14.6 -15 02/20/2006 15:50:00 11.1 1.3 13.7 6.8 9.5 1.5 13.3 4.9 258 7 256 305 -14.7 0 -14.6 -14.8 02/20/2006 16:00:00 11.4 1.2 14.5 6.8 10.1 1.4 13.3 5.3 255 6 255 305 -14.8 0 -14.6 -15 02/20/2006 16:10:00 11.2 1.4 14.1 7.2 9.1 1.3 13 5.3 265 6 271 305 -15.2 0 -14.8 -15.4 02/20/2006 16:20:00 11 1.5 13.7 6.8 9 1.5 13.7 5.3 262 7 268 305 -15 0 -14.6 -15.2 02/20/2006 16:30:00 11.4 1.5 14.9 7.2 9.7 1.6 14.9 6.1 258 7 257 305 -15 0 -14.6 -15 02/20/2006 16:40:00 11.8 1.5 15.3 7.2 10.2 1.6 14.5 6.1 259 6 262 305 -15.1 0 -14.8 -15 02/20/2006 16:50:00 11.7 1.2 14.5 8.4 9.8 1.3 13.3 6.5 259 7 264 305 -15.1 0 -15 -15 02/20/2006 17:00:00 12.1 1.5 15.3 6.8 10 1.4 13.7 6.1 262 7 267 305 -15.2 0 -15 -15.4 02/20/2006 17:10:00 12.3 1.3 15.6 9.1 10.1 1.3 14.5 6.8 263 6 265 305 -15.2 0 -15 -15.4 02/20/2006 17:20:00 10.5 1.6 14.5 6.5 8.6 1.6 13 4.9 264 7 264 305 -15.1 0 -14.8 -15.2 02/20/2006 17:30:00 10.7 1.7 14.9 6.8 8.8 1.6 12.6 4.9 264 8 262 305 -15.1 0 -14.8 -15.2 02/20/2006 17:40:00 10.9 1.7 14.9 6.5 9.1 1.6 13 5.3 263 8 261 305 -15 0 -14.8 -15 02/20/2006 17:50:00 10.8 1.2 13.3 6.5 9.3 1.2 12.6 4.9 258 7 272 305 -15.1 0 -15 -15.2 02/20/2006 18:00:00 10.6 1.3 13.7 6.5 8.9 1.2 11.8 4.2 259 8 268 305 -15.2 0 -15 -15.2 02/20/2006 18:10:00 10.9 1.8 14.9 6.5 9.3 1.7 13.3 5.3 260 7 257 305 -15.1 0 -15 -15.2 02/20/2006 18:20:00 10.5 1.6 14.1 6.5 8.6 1.6 12.6 3.8 265 9 283 305 -15.1 0 -15 -15.2 02/20/2006 18:30:00 12.4 1.2 15.6 9.5 10.9 1.5 15.3 6.5 256 6 257 305 -15.3 0 -15 -15.4 02/20/2006 18:40:00 12.4 1.3 15.3 8 11.1 1.6 14.5 6.8 256 6 254 305 -15.3 0 -15.2 -15.6 02/20/2006 18:50:00 11.8 1.6 14.9 7.6 10.3 1.7 14.1 6.5 257 6 252 305 -15.4 0 -15.2 -15.6 02/20/2006 19:00:00 12 1.3 14.9 8 10.6 1.7 14.5 5.7 255 6 256 305 -15.3 0 -14.8 -15.6 02/20/2006 19:10:00 10.7 1.2 13.7 7.6 9.3 1.5 13.7 5.7 255 7 261 305 -15.3 0 -14.6 -15.6 02/20/2006 19:20:00 9.9 1.1 12.6 6.8 8.4 1.3 11.5 5.3 256 6 250 305 -15.4 0 -15.2 -15.6 02/20/2006 19:30:00 9.5 1.1 12.2 6.1 8.2 1.1 11.1 4.6 257 6 262 305 -15.4 0 -15.2 -15.6 02/20/2006 19:40:00 8.9 1.1 11.5 5.7 7.8 1.1 10.7 4.6 254 6 256 305 -15.5 0 -15.2 -15.6 02/20/2006 19:50:00 8.6 1 10.7 5.7 7.5 1.2 11.1 4.6 255 6 246 305 -15.5 0 -15.4 -15.6 02/20/2006 20:00:00 8.6 1 11.1 5.7 7.5 1.1 10.7 4.6 255 6 251 305 -15.5 0 -15.2 -15.6 02/20/2006 20:10:00 9 1 11.1 6.1 8 1.2 11.5 5.3 253 6 259 305 -15.3 0 -14.8 -15.6 02/20/2006 20:20:00 8.9 1 11.1 5.3 8.1 1.2 11.1 4.9 253 5 242 305 -15.3 0 -14.6 -15.4 02/20/2006 20:30:00 9 1.2 11.1 6.1 8.2 1.3 10.7 5.3 252 7 253 305 -15.3 0 -14.6 -15.4 02/20/2006 20:40:00 8.8 1 11.1 6.1 8 1.2 10.7 5.3 250 6 251 305 -15.3 0 -14.8 -15.4 02/20/2006 20:50:00 8.9 1.1 11.5 6.1 8.1 1.2 10.3 5.3 252 7 257 305 -15.3 0 -14.6 -15.4 02/20/2006 21:00:00 8.5 1.1 11.5 5.7 7.6 1.3 11.1 4.9 254 6 255 305 -15.3 0 -15.2 -15.4 02/20/2006 21:10:00 8.6 1.3 11.5 4.9 7.4 1.4 11.5 4.2 256 8 242 305 -15.3 0 -15 -15.4 02/20/2006 21:20:00 7.8 1.1 10.7 4.9 6.9 1.1 9.9 3.8 251 7 259 305 -15.4 0 -15.2 -15.6 02/20/2006 21:30:00 8.1 0.8 10.3 5.7 7.4 0.9 10.3 4.9 248 6 249 305 -15.5 0 -14.8 -15.6 02/20/2006 21:40:00 7.8 0.9 9.9 5.3 7.3 1 9.5 4.9 247 6 241 305 -15.4 0 -15.2 -15.6 02/20/2006 21:50:00 7.2 0.9 9.1 4.9 6.7 1 9.1 4.6 246 7 240 305 -15.2 0 -15 -15.4 02/20/2006 22:00:00 6.8 0.9 9.1 4.6 6.3 0.9 9.1 4.2 242 7 251 305 -15.2 0 -15 -15.4 02/20/2006 22:10:00 7.8 0.7 10.3 6.1 7.2 0.8 8.8 5.3 237 5 239 305 -15.3 0 -15 -15.4 02/20/2006 22:20:00 7.8 0.8 9.5 5.7 7.2 0.9 9.5 5.3 239 5 234 305 -15.2 0 -15 -15.4 02/20/2006 22:30:00 7.9 0.9 9.9 5.3 7.4 1 9.5 4.9 241 6 237 305 -15.1 0 -15 -15.2 02/20/2006 22:40:00 7.8 0.7 9.5 5.3 7.2 0.7 8.8 4.9 239 5 227 305 -15.1 0 -15 -15.2 02/20/2006 22:50:00 7.4 0.8 9.1 4.9 6.8 0.8 8.8 4.9 239 6 237 305 -15 0 -14.8 -15 02/20/2006 23:00:00 8.1 0.8 9.9 6.1 7.5 0.8 9.5 5.3 239 5 238 305 -14.9 0 -14.6 -15 02/20/2006 23:10:00 7.3 0.9 9.1 5.3 6.7 0.9 9.1 4.9 236 6 238 305 -14.8 0 -14.6 -15 02/20/2006 23:20:00 7.7 0.8 9.9 5.3 7.1 0.8 9.5 4.9 227 5 231 305 -15 0.1 -14.6 -15.2 02/20/2006 23:30:00 7.6 0.8 9.5 5.7 7 0.8 8.8 4.9 233 5 236 305 -15 0 -14.8 -15 02/20/2006 23:40:00 7.7 0.8 9.5 5.7 7.1 0.8 9.5 4.9 233 5 241 305 -14.9 0 -14.8 -15 02/20/2006 23:50:00 7.6 0.7 9.1 5.7 6.9 0.8 8.8 4.9 234 5 232 305 -14.9 0 -14.8 -15 02/21/2006 00:00:00 7.3 0.7 8.8 5.3 6.5 0.8 8.4 4.6 233 5 235 305 -14.9 0 -14.4 -15 02/21/2006 00:10:00 7.1 0.6 8.8 5.3 6.5 0.8 8 4.9 235 5 234 305 -14.8 0 -14.6 -15 02/21/2006 00:20:00 7.2 0.8 9.1 5.3 6.7 0.8 8.8 4.9 230 7 238 305 -14.9 0.1 -14.6 -15 02/21/2006 00:30:00 7.1 0.8 8.4 4.6 6.6 0.8 8.4 4.9 227 5 228 305 -15.2 0 -15 -15.4 02/21/2006 00:40:00 7.4 0.7 8.8 5.3 6.9 0.8 8.8 4.9 228 5 232 305 -15.3 0 -15 -15.4 02/21/2006 00:50:00 6.9 0.6 8.4 4.9 6.3 0.7 8 4.6 224 5 230 305 -15.5 0.1 -15.2 -15.6 02/21/2006 01:00:00 6 0.6 7.6 4.6 5.5 0.6 7.2 3.8 224 5 229 305 -15.7 0 -15.6 -15.8 02/21/2006 01:10:00 7 0.6 8.8 5.7 6.4 0.5 7.6 4.6 223 5 232 305 -15.8 0 -15.6 -16 02/21/2006 01:20:00 6.6 0.7 8 4.9 6 0.7 8 4.2 226 5 229 305 -15.9 0 -15.8 -16.2 02/21/2006 01:30:00 6.5 0.6 7.6 4.9 5.9 0.6 7.6 4.2 223 5 225 305 -16.2 0.1 -15.6 -16.4 02/21/2006 01:40:00 6.2 0.6 8 4.9 5.7 0.6 7.2 4.2 223 5 231 305 -16.4 0 -15.8 -16.6 02/21/2006 01:50:00 5.6 0.5 6.8 4.2 5.1 0.5 6.1 3.8 221 5 228 305 -16.6 0.1 -16.4 -16.9 02/21/2006 02:00:00 5.8 0.5 7.2 4.2 5.3 0.5 6.5 3.8 222 5 224 305 -16.9 0 -16.2 -16.9 02/21/2006 02:10:00 5.8 0.5 7.2 4.6 5.2 0.5 6.5 3.8 223 5 227 305 -16.9 0 -16.9 -16.9 02/21/2006 02:20:00 5.4 0.5 6.5 4.2 4.9 0.4 5.7 3.8 222 5 230 305 -17 0 -16.4 -17.1 02/21/2006 02:30:00 5.3 0.3 6.1 4.2 4.9 0.4 5.7 3.4 219 4 225 305 -17.1 0 -16.9 -17.3 02/21/2006 02:40:00 5.4 0.4 6.5 4.6 5 0.4 6.1 3.8 220 3 224 305 -17.2 0 -16.6 -17.3 02/21/2006 02:50:00 4.9 0.4 5.7 3.8 4.5 0.4 5.7 3.4 222 4 218 305 -17.4 0 -16.9 -17.5 02/21/2006 03:00:00 4.8 0.4 5.7 3.8 4.3 0.4 5.3 3.4 224 4 227 305 -17.4 0 -16.9 -17.5 02/21/2006 03:10:00 4.9 0.3 6.1 3.8 4.5 0.3 5.3 3.4 221 4 218 305 -17.4 0.1 -16.9 -17.5 02/21/2006 03:20:00 4.3 0.5 5.3 3 3.9 0.4 4.9 2.6 217 4 219 305 -17.5 0.1 -16.9 -17.5 02/21/2006 03:30:00 3.9 0.3 4.9 3 3.6 0.4 4.6 2.6 216 7 217 305 -17.4 0.1 -16.9 -17.5 02/21/2006 03:40:00 3.9 0.3 4.9 3 3.7 0.3 4.6 3 216 6 215 305 -17.4 0.1 -16.9 -17.5 02/21/2006 03:50:00 3.7 0.4 4.6 2.6 3.6 0.4 4.6 2.6 209 6 208 305 -17.4 0.1 -16.9 -17.5 02/21/2006 04:00:00 3.7 0.4 4.6 3 3.6 0.4 4.6 2.6 209 6 213 305 -17.3 0.1 -16.9 -17.5 02/21/2006 04:10:00 3.9 0.4 4.9 2.6 3.7 0.4 4.6 2.6 209 6 211 305 -17.3 0.1 -16.9 -17.5 02/21/2006 04:20:00 3.8 0.4 4.9 2.6 3.8 0.4 4.9 2.6 203 6 192 305 -17.3 0 -16.9 -17.5 02/21/2006 04:30:00 3.7 0.4 4.9 2.6 3.6 0.4 4.6 2.3 200 6 207 305 -17.3 0 -17.1 -17.5 02/21/2006 04:40:00 3.1 0.3 3.8 2.3 3 0.4 4.2 2.3 204 6 204 305 -17.3 0 -16.9 -17.5 02/21/2006 04:50:00 3.2 0.4 4.2 1.9 3.1 0.4 4.2 1.9 203 7 214 305 -17.2 0 -16.9 -17.3 02/21/2006 05:00:00 2.9 0.4 3.8 1.9 2.7 0.4 3.4 1.9 215 9 212 305 -17.1 0 -16.9 -17.3 02/21/2006 05:10:00 3 0.3 3.8 1.9 2.7 0.3 3.4 1.9 215 7 222 305 -17.3 0 -16.9 -17.5 02/21/2006 05:20:00 2.6 0.4 3.8 1.5 2.3 0.4 3.4 1.5 210 10 208 305 -17.3 0 -16.9 -17.5 02/21/2006 05:30:00 3 0.3 4.2 2.3 2.8 0.3 3.8 1.9 204 8 194 305 -17.4 0 -16.9 -17.5 02/21/2006 05:40:00 3.1 0.4 4.2 1.9 2.9 0.5 3.8 1.9 201 7 204 305 -17.3 0 -16.9 -17.5 02/21/2006 05:50:00 3.2 0.3 4.2 2.3 3.2 0.4 4.2 2.3 197 6 215 305 -17.2 0 -16.6 -17.3 02/21/2006 06:00:00 3.4 0.4 4.6 2.3 3.4 0.4 4.6 2.6 198 7 198 305 -17.2 0 -16.9 -17.3 02/21/2006 06:10:00 3.7 0.4 4.6 2.3 3.7 0.4 4.6 2.3 199 5 204 305 -17.4 0 -16.7 -17.5 02/21/2006 06:20:00 2.7 0.5 3.8 1.1 2.6 0.5 3.8 1.5 199 7 192 305 -17.4 0 -17.1 -17.5 02/21/2006 06:30:00 2.9 0.3 3.4 2.3 2.8 0.2 3.4 2.3 198 5 200 305 -17.3 0 -17.1 -17.5 02/21/2006 06:40:00 2.7 0.3 3.4 2.3 2.7 0.2 3 2.3 199 4 194 305 -17.3 0.1 -16.9 -17.5 02/21/2006 06:50:00 3 0.4 3.8 1.9 3 0.4 3.8 2.3 196 3 192 305 -17.3 0.1 -16.9 -17.3 02/21/2006 07:00:00 3.2 0.2 3.8 2.6 3.2 0.3 3.8 2.6 193 4 197 305 -17.3 0.1 -16.9 -17.3 02/21/2006 07:10:00 2.7 0.3 3.4 2.3 2.7 0.3 3.4 1.9 202 4 198 305 -17.3 0.1 -16.9 -17.5 02/21/2006 07:20:00 2.7 0.2 3 1.9 2.7 0.2 3 2.3 203 3 203 305 -17.3 0.1 -16.9 -17.5 02/21/2006 07:30:00 3 0.2 3.4 2.3 3 0.2 3.4 2.3 201 2 196 305 -17.2 0.1 -16.7 -17.3 02/21/2006 07:40:00 2.5 0.2 3 1.9 2.5 0.2 3 1.9 204 2 202 305 -17.2 0 -16.9 -17.3 02/21/2006 07:50:00 2.4 0.2 2.6 1.9 2.4 0.2 2.6 1.9 207 2 205 305 -17.3 0.1 -16.6 -17.5 02/21/2006 08:00:00 2.4 0.2 3 1.9 2.4 0.2 3 1.9 213 2 211 305 -17.5 0.1 -16.9 -17.7 02/21/2006 08:10:00 1.9 0.3 2.3 1.5 2 0.2 2.6 1.5 211 4 214 305 -17.6 0 -16.9 -17.7 02/21/2006 08:20:00 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.5 207 2 205 305 -17.6 0 -16.9 -17.9 02/21/2006 08:30:00 1.6 0.3 1.9 1.1 1.6 0.2 1.9 1.1 210 3 208 305 -17.8 0.1 -17.3 -18.1 02/21/2006 08:40:00 1.7 0.2 1.9 1.1 1.6 0.2 1.9 1.1 214 0 214 305 -17.8 0.1 -17.5 -18.1 02/21/2006 08:50:00 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 214 0 214 305 -17.9 0.1 -17.5 -18.1 02/21/2006 09:00:00 1.2 0.4 1.9 0.4 1.1 0.5 1.9 0.4 224 7 214 305 -18.1 0.3 -17.5 -18.6 02/21/2006 09:10:00 0.6 0.3 1.1 0.4 0.5 0.2 0.7 0.4 238 1 231 305 -18.8 0.1 -18.2 -19 02/21/2006 09:20:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 228 5 225 305 -18.3 0.2 -17.7 -18.6 02/21/2006 09:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 225 0 225 305 -18.4 0.2 -17.7 -18.8 02/21/2006 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 225 0 305 305 -18.7 0.2 -18.1 -19 02/21/2006 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 225 0 305 305 -18.4 0.3 -17.5 -19 02/21/2006 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 305 305 -18.2 0.2 -17.5 -18.6 02/21/2006 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 305 305 -18.1 0.2 -17.7 -18.4 02/21/2006 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 305 305 -18.3 0.2 -17.7 -18.4 02/21/2006 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 305 305 -18.1 0.2 -17.7 -18.4 02/21/2006 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 305 305 -18.1 0.2 -17.5 -18.2 02/21/2006 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 305 305 -17.9 0.1 -17.5 -18.1 02/21/2006 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 305 305 -17.9 0.1 -17.5 -18.1 02/21/2006 11:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 263 17 270 305 -17.6 0.2 -16.9 -18.1 02/21/2006 11:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 271 0 271 305 -17.5 0.1 -16.9 -17.7 02/21/2006 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -17.4 0.2 -16.9 -17.7 02/21/2006 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -17 0 -16.6 -17.3 02/21/2006 11:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 271 0 305 305 -16.5 0.1 -16.4 -16.9 02/21/2006 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -16 0.3 -15.2 -16.6 02/21/2006 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -15.3 0 -15 -15.6 02/21/2006 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -14.9 0.1 -14.6 -15.2 02/21/2006 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -14.9 0.1 -14.6 -15.2 02/21/2006 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -15.5 0.2 -14.6 -15.8 02/21/2006 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -15.2 0.1 -14.6 -15.6 02/21/2006 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -14.2 0.2 -13.9 -14.6 02/21/2006 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 272 0 305 305 -14.3 0.4 -13.3 -14.6 02/21/2006 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -12.7 0.3 -12.3 -13.5 02/21/2006 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -12.1 0.1 -11.7 -12.5 02/21/2006 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 305 305 -12.2 0.2 -11.7 -12.5 02/21/2006 13:50:00 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 260 24 204 305 -12.3 0.5 -11.5 -13.3 02/21/2006 14:00:00 1.1 0.2 1.5 0.7 1.1 0.2 1.5 0.7 226 17 205 305 -14.4 0.5 -12.9 -15 02/21/2006 14:10:00 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 242 12 246 305 -14.5 0.4 -13.7 -15 02/21/2006 14:20:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 204 0 205 305 -13.7 0.6 -12.5 -14.4 02/21/2006 14:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 204 0 305 305 -12.4 0.2 -11.9 -12.9 02/21/2006 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 122 43 305 305 -12.3 0.3 -11.7 -12.7 02/21/2006 14:50:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 94 12 71 305 -11.6 0 -11.3 -11.7 02/21/2006 15:00:00 1 0.3 1.9 0.4 1.2 0.3 1.9 0.4 49 10 51 305 -12.2 0.5 -11.5 -13.1 02/21/2006 15:10:00 1.3 0.2 1.9 0.7 1.4 0.3 1.9 0.7 43 8 46 305 -12.9 0 -12.5 -13.1 02/21/2006 15:20:00 1.3 0.3 1.9 0.4 1.2 0.3 1.9 0.4 29 4 35 305 -12.6 0 -12.3 -12.9 02/21/2006 15:30:00 1 0.3 1.5 0.4 0.7 0.3 1.5 0.4 24 4 27 305 -11.9 0.3 -11.3 -12.5 02/21/2006 15:40:00 1 0.4 1.9 0.4 0.9 0.3 1.5 0.4 15 0 15 305 -12.6 0 -12.3 -12.9 02/21/2006 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 305 305 -11.8 0.4 -11.3 -12.7 02/21/2006 16:00:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 15 0 15 305 -11.6 0.4 -11.1 -12.3 02/21/2006 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 305 305 -11.2 0.2 -10.9 -11.9 02/21/2006 16:20:00 0.4 0.2 0.7 0.4 0.4 0.1 0.7 0.4 15 0 15 305 -11.8 0 -11.5 -12.1 02/21/2006 16:30:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 15 0 15 305 -11.7 0.1 -11.5 -12.1 02/21/2006 16:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 15 0 15 305 -11.7 0.3 -11.3 -12.1 02/21/2006 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 305 305 -11.3 0 -10.9 -11.5 02/21/2006 17:00:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 23 8 31 305 -11.2 0.5 -10.4 -12.1 02/21/2006 17:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 31 0 31 305 -12.3 0.3 -11.9 -12.9 02/21/2006 17:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 68 8 31 305 -13.1 0.5 -12.5 -14.3 02/21/2006 17:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 45 22 25 305 -14 0.3 -13.1 -14.4 02/21/2006 17:40:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 25 0 25 305 -13.4 0.1 -12.7 -13.9 02/21/2006 17:50:00 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 41 14 25 305 -14.1 0.3 -13.7 -14.6 02/21/2006 18:00:00 1.2 0.3 1.9 0.7 1.1 0.4 1.9 0.4 68 5 71 305 -14.9 0.2 -14.4 -15.4 02/21/2006 18:10:00 2.5 0.7 3.4 1.1 2.5 0.7 3.8 1.5 52 15 37 305 -15.6 0.1 -15.2 -15.8 02/21/2006 18:20:00 2.7 0.2 3 1.9 2.9 0.2 3.4 2.3 40 4 32 305 -15.2 0.3 -14.8 -16 02/21/2006 18:30:00 2.3 0.2 3.4 1.9 2.4 0.2 3 1.9 26 8 33 305 -14.9 0 -14.6 -15 02/21/2006 18:40:00 2.5 0.3 3.4 1.5 2.7 0.4 4.2 1.5 38 13 47 305 -14.8 0 -14.6 -15 02/21/2006 18:50:00 2.3 0.4 3 1.5 2.4 0.4 3 1.1 36 10 46 305 -14.8 0.1 -14.6 -15.2 02/21/2006 19:00:00 0.7 0.6 3 0.4 0.6 0.4 2.3 0.4 161 36 50 305 -15.7 0.1 -15.2 -16 02/21/2006 19:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 131 43 68 305 -15.8 0 -15.4 -16 02/21/2006 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 68 0 305 305 -16 0.2 -15.6 -16.6 02/21/2006 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 68 0 305 305 -16.8 0.1 -16.4 -16.9 02/21/2006 19:40:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 58 16 21 305 -16.9 0.1 -16.2 -16.9 02/21/2006 19:50:00 1.4 0.6 2.6 0.4 1 0.5 2.3 0.4 42 11 48 305 -16.8 0.1 -16 -16.9 02/21/2006 20:00:00 1.5 0.5 2.6 0.4 1.2 0.5 2.3 0.4 28 13 40 305 -16.3 0.3 -15.4 -16.9 02/21/2006 20:10:00 1.8 0.9 4.2 0.4 1.4 0.7 3.8 0.4 76 30 96 305 -15.6 0.1 -15.2 -16 02/21/2006 20:20:00 3.4 0.8 5.3 1.1 3 1 5.3 0.7 87 12 93 305 -15.4 0.1 -15 -15.8 02/21/2006 20:30:00 2.7 0.6 4.6 1.1 2.7 0.6 4.2 1.5 65 22 77 305 -14.7 0.3 -14.3 -15.2 02/21/2006 20:40:00 1.9 0.5 3.8 0.4 1.9 0.6 3.8 0.4 17 17 8 305 -14 0.1 -13.7 -14.3 02/21/2006 20:50:00 1.7 1.3 5.7 0.4 1.5 1.2 5.3 0.4 50 39 104 305 -13.9 0.1 -13.3 -14.3 02/21/2006 21:00:00 5.5 0.8 7.6 3 5.4 0.8 7.6 3.4 113 8 118 305 -14.1 0.1 -13.7 -14.3 02/21/2006 21:10:00 6.7 0.7 8.4 5.3 6.2 0.6 8 4.9 98 6 87 305 -13.8 0 -13.7 -14.1 02/21/2006 21:20:00 7.8 1.5 10.3 3.8 7.4 1.5 10.3 3.4 101 8 108 305 -13.5 0.1 -13.3 -13.7 02/21/2006 21:30:00 8 1.1 10.3 5.3 7.5 1 9.5 4.6 102 5 106 305 -13.4 0 -13.3 -13.5 02/21/2006 21:40:00 8 0.8 9.5 6.1 7.5 0.8 9.1 5.3 100 5 100 305 -13.2 0 -13.1 -13.5 02/21/2006 21:50:00 7.7 0.7 9.9 5.7 7.3 0.7 9.5 5.3 100 6 92 305 -13 0.1 -12.7 -13.3 02/21/2006 22:00:00 6.8 0.8 8.8 4.6 6.7 0.7 8.4 4.9 108 8 104 305 -12.7 0 -12.5 -12.9 02/21/2006 22:10:00 7.1 0.8 9.5 4.9 7 0.8 9.5 5.3 111 8 113 305 -12.6 0 -12.3 -12.7 02/21/2006 22:20:00 6.9 0.9 9.5 4.2 6.7 0.9 8.8 3.8 111 9 118 305 -12.4 0 -12.3 -12.5 02/21/2006 22:30:00 7.5 0.8 9.5 4.9 7.4 0.8 9.1 4.9 113 9 99 305 -12.4 0 -11.9 -12.5 02/21/2006 22:40:00 8.8 1.1 11.5 5.7 8.7 1 11.5 6.5 114 8 118 305 -12.4 0 -12.1 -12.5 02/21/2006 22:50:00 10.2 1 13 7.6 10.1 1 12.6 7.6 112 6 116 305 -12.2 0 -12.1 -12.5 02/21/2006 23:00:00 11 1.1 13.3 8 10.8 1.2 13.3 7.6 113 8 112 305 -12.1 0 -12.1 -12.3 02/21/2006 23:10:00 11.2 1.1 13.7 8 11.1 1 13.7 8.4 113 7 107 305 -12 0 -11.9 -12.1 02/21/2006 23:20:00 11.3 1.1 14.5 8 11.2 1.1 14.1 8 115 8 116 305 -12 0 -11.9 -12.1 02/21/2006 23:30:00 11.5 1.1 14.5 8.8 11.4 1 13.7 8.4 114 7 112 305 -11.9 0 -11.7 -12.1 02/21/2006 23:40:00 11.1 1 13.3 8 10.9 1 13.7 8.4 114 8 121 305 -11.8 0 -11.7 -12.1 02/21/2006 23:50:00 10.9 1.1 13.7 7.6 10.6 1.1 13.3 7.2 108 7 138 305 -11.9 0 -11.7 -12.1 02/22/2006 00:00:00 11.6 0.9 14.1 8.8 11.3 0.9 13.7 8.4 110 7 109 305 -11.8 0 -11.7 -12.1 02/22/2006 00:10:00 12.2 1.3 16.4 8.8 12 1.2 15.3 9.1 112 8 112 305 -11.8 0 -11.5 -11.9 02/22/2006 00:20:00 12.2 1.1 15.3 9.5 12 1 15.3 9.1 110 8 111 305 -11.7 0 -11.5 -11.9 02/22/2006 00:30:00 11.8 1.2 15.3 8.8 11.6 1.2 15.3 7.6 114 9 114 305 -11.6 0 -11.5 -11.9 02/22/2006 00:40:00 11.5 1.2 14.5 8.4 11.3 1.2 14.1 7.6 113 9 115 305 -11.6 0 -11.5 -11.7 02/22/2006 00:50:00 12.5 1.2 15.6 9.1 12.4 1.2 15.3 9.1 115 7 122 305 -11.5 0 -11.3 -11.7 02/22/2006 01:00:00 13.8 1 16.1 10.3 13.7 1 17.2 9.9 118 5 112 305 -11.6 0 -11.5 -11.7 02/22/2006 01:10:00 13.7 1 15.6 8.8 13.6 1 15.6 8.8 117 5 117 305 -11.6 0 -11.5 -11.7 02/22/2006 01:20:00 13.8 1 16.1 11.1 13.6 1.1 16.1 10.7 117 5 114 305 -11.6 0 -11.5 -11.7 02/22/2006 01:30:00 13.5 1.1 16.8 9.1 13.2 1.1 16.8 9.9 118 5 105 305 -11.7 0 -11.5 -11.9 02/22/2006 01:40:00 13.2 1 16.8 9.9 13 1 15.6 9.1 119 5 111 305 -11.9 0 -11.7 -12.1 02/22/2006 01:50:00 11.9 1.1 14.1 8.4 11.8 1.2 14.1 8 116 6 118 305 -11.9 0 -11.7 -12.1 02/22/2006 02:00:00 10.5 0.8 13 8.4 10.2 0.8 12.2 7.6 109 7 118 305 -11.7 0 -11.5 -11.9 02/22/2006 02:10:00 9.9 0.8 11.8 7.2 9.3 0.8 11.5 6.8 105 5 113 305 -11.4 0 -11.1 -11.7 02/22/2006 02:20:00 8 0.7 9.9 6.1 7.4 0.7 9.1 5.7 103 5 108 305 -11.3 0 -11.1 -11.5 02/22/2006 02:30:00 6.6 0.9 9.1 4.6 6.1 0.9 8.8 3.4 104 7 112 305 -11.2 0 -10.9 -11.3 02/22/2006 02:40:00 5.4 0.7 7.6 3 4.9 0.7 6.8 2.6 98 10 112 305 -11.1 0 -10.9 -11.3 02/22/2006 02:50:00 6.6 1 9.1 4.2 6.1 1 9.1 3.8 99 9 101 305 -11 0 -10.7 -11.3 02/22/2006 03:00:00 7.8 0.8 9.5 5.3 7.1 0.8 8.8 4.6 96 6 94 305 -10.9 0 -10.4 -11.3 02/22/2006 03:10:00 7.8 1 9.5 4.9 7.1 0.8 8.8 4.9 93 6 91 305 -11 0 -10.9 -11.3 02/22/2006 03:20:00 8.4 0.8 10.7 6.5 7.5 0.7 9.9 5.7 96 5 101 305 -10.9 0 -10.7 -11.3 02/22/2006 03:30:00 8 0.9 9.9 4.6 7.1 0.8 8.8 4.2 93 6 97 305 -10.9 0 -10.7 -11.1 02/22/2006 03:40:00 6.8 0.9 9.1 4.6 6.1 0.8 8 3.4 83 12 90 305 -10.7 0 -10.4 -10.9 02/22/2006 03:50:00 6.1 1 9.1 3 5.7 1 8.4 3 68 13 44 305 -10.5 0.1 -10.2 -10.9 02/22/2006 04:00:00 6 0.7 8 4.6 5.4 0.7 7.6 3.8 74 10 70 305 -10.7 0 -10.4 -10.9 02/22/2006 04:10:00 6.9 1 9.1 4.6 6.4 0.9 8.4 3.8 73 10 92 305 -10.4 0 -10.4 -10.7 02/22/2006 04:20:00 7.7 0.8 9.5 5.3 6.9 0.7 8.4 4.9 83 7 88 305 -10.4 0 -10.4 -10.7 02/22/2006 04:30:00 7.7 0.9 9.9 5.7 7 0.8 9.1 4.6 83 8 86 305 -10.3 0 -10 -10.4 02/22/2006 04:40:00 7.8 0.7 9.5 5.7 7.1 0.6 8.4 5.3 87 6 83 305 -10.3 0 -10 -10.4 02/22/2006 04:50:00 7.6 0.8 9.1 5.3 7 0.8 8.8 4.9 84 8 93 305 -10.4 0 -10 -10.4 02/22/2006 05:00:00 6.7 0.7 8.8 4.9 6.2 0.7 8 4.6 78 10 87 305 -10.3 0 -10 -10.4 02/22/2006 05:10:00 7 0.7 9.5 4.9 6.4 0.7 8.4 4.6 77 10 85 305 -10.2 0.1 -9.8 -10.4 02/22/2006 05:20:00 6.9 0.8 8.8 4.6 6.3 0.9 8.4 4.2 79 11 94 305 -10 0 -9.8 -10.2 02/22/2006 05:30:00 6.2 0.9 8.8 3 5.7 0.9 8 3 80 11 72 305 -9.8 0 -9.4 -10 02/22/2006 05:40:00 7 0.9 9.1 4.6 6.4 0.8 8.8 4.6 78 10 70 305 -9.5 0 -9.2 -9.6 02/22/2006 05:50:00 8.3 1 10.7 5.7 7.5 1 9.9 4.9 82 8 89 305 -9.3 0 -9 -9.6 02/22/2006 06:00:00 7.8 0.9 10.3 5.3 7.2 0.9 9.9 4.9 79 8 85 305 -9.1 0.1 -8.8 -9.2 02/22/2006 06:10:00 8 1.1 10.7 4.9 7.3 1.1 10.7 4.9 75 8 77 305 -9 0 -8.8 -9.2 02/22/2006 06:20:00 9.9 1.2 12.2 5.7 9.1 1.2 12.2 5.3 80 8 84 305 -9.1 0.1 -8.8 -9.2 02/22/2006 06:30:00 10.7 1 13.3 7.2 9.9 1.1 12.2 6.5 78 7 66 305 -9 0 -8.8 -9.2 02/22/2006 06:40:00 10.6 1 13 7.6 10 1 12.6 6.1 74 8 74 305 -9 0 -8.8 -9.2 02/22/2006 06:50:00 12 1 14.9 9.5 11.3 1.1 14.9 8.8 74 6 77 305 -9.1 0.1 -8.8 -9.2 02/22/2006 07:00:00 12 1.2 15.3 9.1 11.1 1.1 14.5 8.4 81 7 85 305 -9.1 0.1 -8.8 -9.2 02/22/2006 07:10:00 12.3 1.2 15.6 9.5 11.5 1.2 14.1 8 81 7 81 305 -9.3 0 -9 -9.6 02/22/2006 07:20:00 12.8 1 14.9 9.1 12 1 14.9 9.1 81 7 82 305 -9.4 0 -9.2 -9.6 02/22/2006 07:30:00 12.9 1.1 15.6 10.3 12.1 1.1 15.3 9.1 80 7 82 305 -9.6 0.1 -9.2 -10 02/22/2006 07:40:00 13 1 15.6 10.3 12.2 1 14.9 9.5 80 7 82 305 -10.1 0.1 -9.8 -10.4 02/22/2006 07:50:00 12.7 1 16.1 9.9 11.9 1 14.9 9.1 78 7 74 305 -10.3 0 -10 -10.4 02/22/2006 08:00:00 12.3 1 14.5 10.3 11.7 1 14.1 9.1 74 6 73 305 -10.6 0 -10.2 -10.9 02/22/2006 08:10:00 12.4 0.9 14.9 9.1 11.9 1 14.1 8.8 72 6 71 305 -10.8 0 -10.4 -10.9 02/22/2006 08:20:00 13.3 0.8 15.6 11.1 13 1 15.6 10.7 69 5 71 305 -11 0 -10.9 -11.3 02/22/2006 08:30:00 14 0.8 16.1 11.5 14 1 16.1 11.1 64 4 66 305 -11 0 -10.9 -11.3 02/22/2006 08:40:00 14.7 0.8 16.4 12.6 14.5 1 16.4 11.8 62 3 58 305 -11 0 -10.9 -11.3 02/22/2006 08:50:00 14.3 1 16.1 10.7 14.3 1 16.4 11.1 60 3 62 305 -10.9 0 -10.7 -11.3 02/22/2006 09:00:00 13.7 1 16.4 11.1 13.7 1.2 16.4 11.1 59 3 59 305 -10.8 0 -10.4 -10.9 02/22/2006 09:10:00 14.3 0.8 15.6 12.2 14.2 0.9 16.1 11.5 57 3 56 305 -10.9 0 -10.7 -11.1 02/22/2006 09:20:00 13.6 1 16.1 11.8 13.6 1 16.1 11.5 57 4 58 305 -10.8 0 -10.4 -10.9 02/22/2006 09:30:00 13.6 0.9 15.6 11.5 13.7 1 16.1 11.1 55 3 53 305 -11 0 -10.9 -11.3 02/22/2006 09:40:00 13.7 0.7 15.3 11.1 13.7 0.8 15.3 11.5 51 4 51 305 -11.1 0 -10.9 -11.3 02/22/2006 09:50:00 13.3 1 15.6 11.1 13.2 1.1 15.6 10.7 52 4 48 305 -11.2 0 -10.9 -11.3 02/22/2006 10:00:00 14.2 0.8 15.6 11.8 14.1 1 16.4 11.8 53 3 48 305 -11.2 0 -10.9 -11.5 02/22/2006 10:10:00 13.9 0.8 15.6 11.8 13.9 0.8 16.1 11.5 53 3 51 305 -11.1 0 -10.9 -11.3 02/22/2006 10:20:00 14.1 0.9 16.1 12.2 14.1 0.9 16.1 11.8 51 4 50 305 -11 0 -10.9 -11.3 02/22/2006 10:30:00 14.4 0.9 16.4 11.1 14.3 1.1 16.4 11.1 50 3 46 305 -11 0 -10.9 -11.3 02/22/2006 10:40:00 14.7 0.9 16.4 11.8 14.5 1 16.8 12.2 50 3 48 305 -11 0 -10.9 -11.3 02/22/2006 10:50:00 14.5 1 16.8 11.5 14.4 1 16.4 11.8 50 4 51 305 -11 0 -10.9 -11.1 02/22/2006 11:00:00 14.9 1 17.2 11.8 14.9 1 17.2 11.5 52 4 51 305 -10.9 0 -10.4 -10.9 02/22/2006 11:10:00 13.9 1 15.6 11.1 13.9 1.2 16.1 10.3 52 5 53 305 -10.8 0 -10.4 -10.9 02/22/2006 11:20:00 13 1 15.6 10.7 13 1 15.6 10.7 47 5 54 305 -10.8 0.1 -10.4 -10.9 02/22/2006 11:30:00 13.2 1 15.6 11.1 13.2 1 16.1 10.3 46 4 48 305 -10.8 0 -10.4 -10.9 02/22/2006 11:40:00 13.4 1.1 16.1 10.3 13.3 1.2 16.4 10.3 44 5 42 305 -10.7 0 -10.4 -10.9 02/22/2006 11:50:00 13.4 1 15.6 11.1 13.3 1.2 16.1 10.3 43 5 44 305 -10.6 0 -10.4 -10.9 02/22/2006 12:00:00 12.8 1 15.3 9.9 12.7 1 15.3 9.5 39 5 38 305 -10.8 0 -10.4 -10.9 02/22/2006 12:10:00 13.6 0.9 16.1 10.7 13.6 1 15.6 10.7 41 4 34 305 -10.8 0.1 -10.4 -10.9 02/22/2006 12:20:00 13.5 1.1 15.6 10.7 13.3 1.1 16.1 10.3 39 4 40 305 -10.8 0 -10.4 -10.9 02/22/2006 12:30:00 14.1 1.1 16.4 11.5 13.9 1.1 16.4 10.7 37 5 45 305 -10.9 0 -10.7 -11.1 02/22/2006 12:40:00 13.6 1.2 16.4 10.3 13.6 1.3 16.4 10.7 40 5 40 305 -10.8 0 -10.4 -10.9 02/22/2006 12:50:00 13.3 1.4 16.4 9.5 13.2 1.4 16.4 9.5 40 4 31 305 -10.8 0.1 -10.4 -10.9 02/22/2006 13:00:00 12.5 0.9 14.5 9.9 12.4 1 14.9 9.5 37 5 43 305 -10.8 0.1 -10.4 -10.9 02/22/2006 13:10:00 13 1.2 16.1 10.3 12.8 1.2 15.6 9.5 36 5 29 305 -10.9 0 -10.4 -11.3 02/22/2006 13:20:00 13.9 1.2 17.2 10.7 13.6 1.3 16.8 10.3 34 5 33 305 -11.1 0 -10.9 -11.3 02/22/2006 13:30:00 13.7 1 16.4 10.7 13.5 1.1 16.1 10.7 34 5 37 305 -11.2 0 -10.9 -11.3 02/22/2006 13:40:00 14.3 1.1 16.4 11.5 14 1.1 16.4 11.1 35 5 33 305 -11.2 0 -10.9 -11.3 02/22/2006 13:50:00 14.2 1 16.1 11.1 14 1 16.4 10.7 34 5 37 305 -11.2 0 -10.9 -11.5 02/22/2006 14:00:00 13.8 1.1 16.4 11.1 13.5 1.1 16.8 10.7 31 5 31 305 -11.3 0.1 -11.1 -11.5 02/22/2006 14:10:00 12.8 1.1 15.6 10.3 12.6 1.1 15.3 10.3 31 5 35 305 -11.3 0.1 -11.1 -11.5 02/22/2006 14:20:00 12.7 1.3 16.1 9.5 12.5 1.3 16.1 9.5 28 5 23 305 -11.5 0.2 -10.9 -11.9 02/22/2006 14:30:00 13.3 1.1 16.1 10.7 13 1.1 16.4 9.9 27 5 22 305 -11.8 0 -11.5 -11.9 02/22/2006 14:40:00 14.1 1.1 16.4 11.1 13.8 1.1 16.4 11.5 28 5 34 305 -11.9 0 -11.7 -12.1 02/22/2006 14:50:00 14.2 1.2 17.2 11.1 13.9 1.1 17.2 11.1 30 5 34 305 -12 0 -11.7 -12.1 02/22/2006 15:00:00 13.4 1.2 16.4 10.7 13.3 1.2 16.1 10.3 27 5 32 305 -12.1 0.1 -11.9 -12.5 02/22/2006 15:10:00 13.9 1.3 16.4 10.3 13.7 1.3 16.1 9.9 27 4 29 305 -12.5 0 -12.1 -12.7 02/22/2006 15:20:00 13.5 1.1 15.6 9.5 13.3 1.1 15.6 9.9 26 4 26 305 -12.7 0 -12.5 -12.9 02/22/2006 15:30:00 13.1 1.1 15.3 10.3 12.8 1.1 15.3 10.3 28 4 27 305 -12.8 0 -12.5 -12.9 02/22/2006 15:40:00 12.7 1.3 16.1 9.5 12.4 1.3 15.6 8.4 27 5 30 305 -12.8 0 -12.5 -12.9 02/22/2006 15:50:00 12.7 1.3 15.6 9.5 12.2 1.3 14.9 9.1 28 5 33 305 -12.7 0 -12.5 -12.9 02/22/2006 16:00:00 12.2 1.2 15.3 9.1 12 1.2 14.9 9.1 29 5 29 305 -12.7 0 -12.5 -12.9 02/22/2006 16:10:00 12.7 1 15.3 9.5 12.4 1.1 14.5 9.9 26 5 27 305 -12.8 0 -12.5 -12.9 02/22/2006 16:20:00 12.4 1.2 14.9 9.1 12.1 1.2 14.5 9.1 26 5 27 305 -12.8 0 -12.5 -12.9 02/22/2006 16:30:00 12.4 1 15.3 9.9 12.3 1 15.3 9.5 22 6 22 305 -12.9 0 -12.7 -13.1 02/22/2006 16:40:00 12.5 1 14.9 9.9 12.3 1 14.9 9.5 21 5 14 305 -12.8 0 -12.7 -12.9 02/22/2006 16:50:00 12.2 1.2 14.5 8.4 11.9 1.3 14.5 8.4 22 5 25 305 -12.9 0.1 -12.7 -13.1 02/22/2006 17:00:00 11.9 1.1 14.1 8.4 11.7 1.1 14.9 8.8 19 5 16 305 -13 0 -12.9 -13.1 02/22/2006 17:10:00 11.7 1.1 14.1 8.8 11.6 1 14.1 8.8 21 5 23 305 -13 0 -12.9 -13.1 02/22/2006 17:20:00 12.4 0.8 14.5 9.9 12.3 0.9 14.5 9.1 21 4 17 305 -12.9 0 -12.7 -13.1 02/22/2006 17:30:00 11.3 1 13.7 8.8 11.2 1.2 13.7 8.4 20 5 27 305 -12.7 0 -12.5 -12.9 02/22/2006 17:40:00 10.8 1.1 13.3 8.8 10.8 1.1 13.3 8.4 16 5 14 305 -12.6 0 -12.5 -12.9 02/22/2006 17:50:00 11.6 1.1 14.1 9.1 11.5 1.2 14.1 8.8 12 5 17 305 -12.8 0.1 -12.5 -13.1 02/22/2006 18:00:00 12.1 1.1 14.5 9.5 12 1.1 14.1 9.5 14 5 14 305 -13 0 -12.9 -13.1 02/22/2006 18:10:00 10.5 1 12.6 7.6 10.4 1 13 8 10 5 5 305 -13.1 0 -12.9 -13.3 02/22/2006 18:20:00 11.1 1 13.3 8.4 11.1 1 13.7 8 9 5 1 305 -13.3 0 -13.1 -13.5 02/22/2006 18:30:00 11.1 1 13 8.4 11 1.1 13.7 7.6 8 5 358 305 -13.5 0.1 -13.1 -13.7 02/22/2006 18:40:00 11 1.1 13.3 8 10.9 1.1 13.7 8 8 4 9 305 -13.9 0.1 -13.7 -14.3 02/22/2006 18:50:00 10.6 1 13 8.4 10.6 1 12.6 8 13 4 7 305 -14.1 0 -13.9 -14.3 02/22/2006 19:00:00 10 1 12.2 7.6 10 1.1 12.6 7.6 9 5 8 305 -14.2 0 -13.9 -14.3 02/22/2006 19:10:00 9.9 0.9 11.5 7.2 9.9 0.8 11.8 7.6 8 5 14 305 -14.3 0 -14.1 -14.4 02/22/2006 19:20:00 9.3 1 11.8 6.5 9.3 1 12.6 6.5 8 6 17 305 -14.2 0 -14.1 -14.4 02/22/2006 19:30:00 9.5 0.9 11.5 6.8 9.5 0.9 11.5 6.8 4 4 359 305 -14.5 0.1 -14.3 -14.6 02/22/2006 19:40:00 9.6 0.9 11.5 7.6 9.5 1 11.5 6.5 5 5 0 305 -14.9 0.1 -14.6 -15 02/22/2006 19:50:00 9.2 1.3 12.2 6.5 9.2 1.2 11.8 6.5 12 6 12 305 -15.1 0 -15 -15.2 02/22/2006 20:00:00 8.5 0.9 11.1 6.5 8.4 1 11.1 5.7 14 5 25 305 -15 0 -14.6 -15 02/22/2006 20:10:00 7.2 1.1 9.9 4.6 7.2 1.2 9.9 4.2 9 5 8 305 -15.1 0 -14.6 -15.2 02/22/2006 20:20:00 7.2 1 9.1 4.6 7.2 1 9.5 4.6 6 5 6 305 -15.2 0 -15 -15.4 02/22/2006 20:30:00 7.4 0.8 9.1 5.3 7.3 0.9 9.5 4.9 7 7 8 305 -15.3 0 -15.2 -15.6 02/22/2006 20:40:00 7.1 0.8 9.1 5.3 6.9 0.8 9.1 5.3 11 5 10 305 -15.4 0 -15 -15.6 02/22/2006 20:50:00 6.4 1.2 8.4 4.2 6.4 1.1 8.4 4.2 5 5 0 305 -15.4 0 -15 -15.6 02/22/2006 21:00:00 6.4 0.7 8 4.2 6.3 0.8 8.4 4.2 4 6 11 305 -15.6 0 -15 -15.6 02/22/2006 21:10:00 6.7 0.5 8 5.3 6.7 0.5 8.4 5.3 1 4 3 305 -15.5 0 -15.4 -15.6 02/22/2006 21:20:00 6.5 0.7 8.4 4.2 6.5 0.8 8.4 4.2 2 5 358 305 -15.4 0 -15 -15.6 02/22/2006 21:30:00 5.2 0.6 6.5 3.8 5.1 0.7 6.8 3.4 15 9 5 305 -15.3 0 -15 -15.4 02/22/2006 21:40:00 4.9 0.6 6.5 3.4 4.8 0.6 6.5 3.8 21 7 18 305 -15.3 0 -15 -15.6 02/22/2006 21:50:00 4.3 0.7 6.1 3 4.2 0.6 6.1 3 18 6 15 305 -15.4 0 -15.2 -15.6 02/22/2006 22:00:00 4.1 0.6 5.3 2.6 4 0.6 5.7 2.6 12 6 19 305 -15.3 0 -15 -15.6 02/22/2006 22:10:00 4 0.4 4.9 3 3.8 0.4 4.6 2.6 3 5 5 305 -15.3 0 -15 -15.4 02/22/2006 22:20:00 3.9 0.4 4.6 3 3.8 0.4 4.6 3 6 4 8 305 -15.2 0 -15 -15.4 02/22/2006 22:30:00 3.1 0.4 4.2 1.9 2.9 0.4 3.8 1.9 5 5 0 305 -15.4 0 -14.8 -15.6 02/22/2006 22:40:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 15 4 3 305 -15.7 0 -15.4 -15.8 02/22/2006 22:50:00 2.6 0.3 3 2.3 2.6 0.3 3 1.9 22 7 18 305 -15.4 0.1 -15 -15.8 02/22/2006 23:00:00 2.7 0.2 3.4 2.3 2.7 0.3 3.4 1.9 36 7 42 305 -15.1 0.1 -14.6 -15.2 02/22/2006 23:10:00 2.6 0.4 3.4 1.9 2.7 0.4 3.4 1.5 32 7 40 305 -15.3 0.1 -15 -15.6 02/22/2006 23:20:00 2.1 0.4 3 1.5 2.1 0.4 3 1.5 19 7 30 305 -15.1 0 -15 -15.2 02/22/2006 23:30:00 1.3 0.4 2.3 0.4 1.5 0.3 2.3 0.7 4 11 21 305 -15.3 0 -15 -15.6 02/22/2006 23:40:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0 6 355 305 -15.5 0 -15.2 -15.6 02/22/2006 23:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 355 0 355 305 -15.8 0 -15.6 -16 02/23/2006 00:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 304 41 264 305 -15.6 0.2 -15 -16 02/23/2006 00:10:00 1 0.4 2.3 0.4 0.8 0.4 2.3 0.4 246 13 247 305 -15.1 0 -15 -15.2 02/23/2006 00:20:00 1.5 0.2 2.3 1.1 1.4 0.3 2.3 0.7 230 14 244 305 -15.3 0 -15 -15.6 02/23/2006 00:30:00 2.2 0.4 3.4 1.5 2.3 0.3 3 1.5 211 8 221 305 -15.3 0 -15 -15.4 02/23/2006 00:40:00 3.7 0.6 5.3 2.6 3.7 0.6 4.9 2.6 213 6 218 305 -15.4 0.1 -15 -15.6 02/23/2006 00:50:00 4.7 0.4 5.3 3.8 4.4 0.4 5.3 3.4 217 6 225 305 -14.9 0.1 -14.6 -15.2 02/23/2006 01:00:00 5.5 0.5 6.5 4.2 5 0.4 6.1 3.8 221 4 223 305 -14.8 0 -14.6 -15 02/23/2006 01:10:00 5.6 0.3 6.1 4.9 5.2 0.3 6.1 4.2 226 3 221 305 -14.7 0 -14.4 -15 02/23/2006 01:20:00 5.8 0.3 6.5 4.9 5.3 0.3 6.1 4.2 229 2 228 305 -14.4 0 -14.3 -14.6 02/23/2006 01:30:00 5.9 0.4 6.8 4.9 5.4 0.4 6.5 4.2 229 3 229 305 -14.3 0 -14.3 -14.4 02/23/2006 01:40:00 5.9 0.4 7.2 4.9 5.4 0.4 6.5 4.6 231 5 244 305 -14.4 0 -14.3 -14.6 02/23/2006 01:50:00 5.9 0.5 7.2 4.6 5.4 0.5 6.5 3.8 232 3 235 305 -14.5 0.1 -14.3 -14.6 02/23/2006 02:00:00 5.7 0.3 6.5 4.6 5.3 0.4 6.1 3.8 232 3 232 305 -14.7 0 -14.4 -14.8 02/23/2006 02:10:00 5.6 0.4 6.5 4.6 5 0.4 5.7 3.8 235 4 237 305 -14.7 0 -14.4 -14.8 02/23/2006 02:20:00 5.3 0.3 6.1 4.2 5 0.4 5.7 3.8 229 3 234 305 -14.8 0 -14.6 -15 02/23/2006 02:30:00 5.6 0.4 6.5 4.2 5.3 0.4 6.1 4.2 232 3 236 305 -14.7 0 -14.6 -14.8 02/23/2006 02:40:00 5.3 0.3 6.5 4.2 4.9 0.4 5.7 3.8 229 4 228 305 -14.7 0 -14.6 -14.8 02/23/2006 02:50:00 5.4 0.5 6.5 4.2 5.1 0.5 6.5 3.8 227 6 231 305 -14.7 0 -14.6 -15 02/23/2006 03:00:00 5.1 0.4 6.1 4.2 4.7 0.4 5.7 3.4 225 7 228 305 -14.8 0 -14.6 -15 02/23/2006 03:10:00 5.9 0.5 7.2 4.2 5.3 0.6 6.8 3.4 234 5 236 305 -14.7 0.1 -14.4 -15 02/23/2006 03:20:00 5.6 0.5 7.2 4.6 5.2 0.5 6.5 3.8 229 6 234 305 -14.6 0 -14.4 -14.6 02/23/2006 03:30:00 5 0.8 6.8 3.4 4.4 0.6 6.5 2.6 236 10 249 305 -14.6 0.1 -14.3 -14.6 02/23/2006 03:40:00 5.8 0.8 8 3.4 5.1 0.8 6.8 3.4 242 8 251 305 -14.2 0 -14.1 -14.4 02/23/2006 03:50:00 6.2 0.8 8 4.6 5.4 0.8 7.6 3.4 248 8 250 305 -14 0 -13.7 -14.3 02/23/2006 04:00:00 5.6 0.8 7.2 3.4 4.5 0.8 6.5 2.6 252 10 261 305 -13.7 0 -13.5 -14.1 02/23/2006 04:10:00 6.2 1 8.8 3.8 5.4 1 8.4 3.4 249 8 247 305 -13.8 0 -13.7 -14.1 02/23/2006 04:20:00 6.7 1 8.4 4.2 5.7 1 7.6 3 252 6 258 305 -13.9 0 -13.7 -14.1 02/23/2006 04:30:00 7 1 9.1 4.6 5.7 1 8 3.4 255 7 252 305 -13.9 0 -13.7 -14.1 02/23/2006 04:40:00 7 1 9.1 4.6 5.4 0.9 7.6 3 258 7 267 305 -13.7 0 -13.5 -13.9 02/23/2006 04:50:00 6.3 0.9 8.8 4.2 4.9 0.8 7.2 3 257 9 262 305 -13.7 0 -13.7 -13.9 02/23/2006 05:00:00 6 1 8.4 2.6 4.9 1 7.6 1.9 254 9 259 305 -13.7 0 -13.5 -13.9 02/23/2006 05:10:00 5.9 0.7 7.6 4.2 5.1 0.7 6.8 3.4 246 8 246 305 -13.8 0 -13.7 -13.9 02/23/2006 05:20:00 6.3 0.7 9.1 4.2 5.5 0.7 7.6 3 245 6 254 305 -13.8 0 -13.7 -13.9 02/23/2006 05:30:00 6.9 1 9.1 4.2 5.8 1 8.4 3 249 7 257 305 -13.6 0 -13.3 -13.7 02/23/2006 05:40:00 7.4 1 9.5 4.9 6 1 8 3 253 7 259 305 -13.6 0 -13.3 -13.7 02/23/2006 05:50:00 7.7 1.2 10.3 4.9 6.3 1 8.8 3.4 256 6 263 305 -13.6 0 -13.5 -13.7 02/23/2006 06:00:00 8.4 1.2 10.7 5.3 6.6 1.2 9.9 3.4 256 7 253 305 -13.7 0 -13.7 -13.9 02/23/2006 06:10:00 6.9 1.1 9.5 4.6 5.6 1.1 8.4 3 256 9 259 305 -13.7 0 -13.7 -13.9 02/23/2006 06:20:00 7.2 1 9.5 4.6 6 1.1 8.4 3.4 251 7 248 305 -13.9 0 -13.7 -14.1 02/23/2006 06:30:00 7.5 0.9 9.9 4.6 5.9 1 8.8 3.4 256 8 264 305 -14 0 -13.7 -14.1 02/23/2006 06:40:00 7.2 1 9.5 4.2 5.6 1 8.4 3 257 9 263 305 -14 0 -13.7 -14.3 02/23/2006 06:50:00 6.1 0.7 8 4.6 5.2 0.7 7.2 3 247 8 258 305 -14.2 0.1 -13.7 -14.6 02/23/2006 07:00:00 6.3 1 8.8 4.2 5.2 1 7.6 3 251 7 257 305 -14.4 0 -14.3 -14.6 02/23/2006 07:10:00 6.1 1.3 9.1 3.4 5.1 1 7.6 3 248 8 259 305 -14.4 0.1 -14.3 -14.6 02/23/2006 07:20:00 6.4 1 8.8 4.2 5.3 0.9 7.6 3 253 7 259 305 -14.5 0 -14.3 -14.6 02/23/2006 07:30:00 6.3 0.6 7.6 4.6 5.5 0.7 7.2 3.4 247 5 245 305 -14.7 0 -14.4 -14.8 02/23/2006 07:40:00 6.3 0.8 8.8 4.6 5.2 0.7 7.2 3.4 249 8 259 305 -14.9 0 -14.6 -15 02/23/2006 07:50:00 7.5 1.2 9.9 3.4 6.1 1.2 8.8 3.4 252 8 266 305 -14.6 0 -14.4 -14.8 02/23/2006 08:00:00 6 0.7 7.6 4.2 5.1 0.7 7.2 3.4 242 6 248 305 -14.9 0.1 -14.6 -15 02/23/2006 08:10:00 6.6 0.8 8 4.2 5.7 0.9 7.6 3.8 241 5 246 305 -15 0 -14.6 -15 02/23/2006 08:20:00 7.1 0.8 8.8 4.2 6.2 0.9 8.4 3.4 238 5 238 305 -15.2 0 -14.8 -15.4 02/23/2006 08:30:00 7.1 0.6 8.8 5.3 6 0.7 7.6 4.2 242 5 246 305 -15.3 0 -15 -15.4 02/23/2006 08:40:00 6.8 0.5 8 5.3 6 0.5 7.2 4.6 242 5 237 305 -15.3 0 -15.2 -15.4 02/23/2006 08:50:00 6.7 0.9 8.8 4.2 5.5 1 8.8 3 251 7 256 305 -15.1 0.1 -14.6 -15.4 02/23/2006 09:00:00 6.5 1 8.8 3.8 5.3 0.9 7.6 3.4 254 6 254 305 -14.8 0 -14.6 -15 02/23/2006 09:10:00 5.9 0.8 7.6 3.8 4.9 0.8 6.8 2.6 251 6 259 305 -14.8 0 -14.6 -15 02/23/2006 09:20:00 5.4 0.5 7.2 3.8 4.5 0.6 6.1 3 247 5 245 305 -14.9 0 -14.6 -15 02/23/2006 09:30:00 5.8 0.7 7.2 4.2 4.8 0.7 6.5 3.4 245 4 253 305 -15 0 -14.8 -15 02/23/2006 09:40:00 4.5 0.9 6.8 2.6 3.6 0.8 5.7 1.9 244 6 242 305 -14.9 0 -14.6 -15 02/23/2006 09:50:00 2.3 0.9 4.2 0.4 2 0.6 3.8 0.7 223 17 247 305 -15.2 0.1 -14.8 -15.4 02/23/2006 10:00:00 2.9 0.3 3.4 2.3 2.8 0.3 3.4 2.3 225 7 219 305 -15.3 0 -15 -15.4 02/23/2006 10:10:00 3.8 0.4 4.9 3 3.3 0.3 4.6 2.6 228 4 237 305 -15.4 0.1 -15 -15.6 02/23/2006 10:20:00 4.9 0.4 6.1 4.2 4.3 0.4 5.3 3 232 4 234 305 -15.4 0.1 -15.2 -15.8 02/23/2006 10:30:00 4.5 0.6 6.1 3 4.1 0.4 4.9 3 227 6 238 305 -15.2 0 -15 -15.4 02/23/2006 10:40:00 6 0.6 7.2 3.8 5.4 0.7 6.8 3.4 231 5 232 305 -15 0.2 -14.6 -15.4 02/23/2006 10:50:00 6.4 0.5 7.6 4.9 5.5 0.6 7.2 4.2 235 4 235 305 -14.7 0 -14.4 -14.8 02/23/2006 11:00:00 5.1 0.6 6.8 3.8 4.5 0.6 6.1 3 227 6 241 305 -14.6 0 -14.4 -14.8 02/23/2006 11:10:00 5.8 0.4 6.8 4.6 5.5 0.4 6.5 4.6 220 3 222 305 -14.7 0 -14.3 -14.6 02/23/2006 11:20:00 5 0.5 6.1 3.8 4.7 0.5 5.7 3 215 5 224 305 -14.5 0.1 -14.3 -14.6 02/23/2006 11:30:00 4.2 0.3 4.9 2.6 4 0.3 4.9 3 213 4 211 305 -14.4 0 -14.3 -14.4 02/23/2006 11:40:00 3.8 0.5 4.9 2.6 3.7 0.4 4.6 2.6 208 6 213 305 -14.2 0.1 -13.7 -14.4 02/23/2006 11:50:00 3.8 0.3 4.6 3 3.8 0.3 4.6 2.6 206 5 210 305 -14 0 -13.5 -14.3 02/23/2006 12:00:00 4.1 0.3 4.9 3.4 4.2 0.3 4.9 3.4 204 5 208 305 -13.7 0 -13.3 -13.9 02/23/2006 12:10:00 4.3 0.4 5.3 3 4.2 0.5 5.3 2.6 203 5 200 305 -13.5 0.1 -13.1 -13.7 02/23/2006 12:20:00 4.1 0.4 4.9 3 4 0.4 4.9 3 207 4 208 305 -13.3 0 -12.9 -13.5 02/23/2006 12:30:00 3.3 0.5 4.6 1.9 3.3 0.5 4.2 1.9 197 6 192 305 -13 0.1 -12.5 -13.3 02/23/2006 12:40:00 4.1 0.3 5.3 3.4 4.3 0.4 5.3 3.4 191 4 191 305 -12.9 0.1 -12.5 -12.9 02/23/2006 12:50:00 4.2 0.3 4.6 3.4 4.3 0.3 4.9 3 194 3 197 305 -12.7 0 -12.3 -12.9 02/23/2006 13:00:00 3.8 0.3 4.6 2.6 3.7 0.4 4.9 2.3 197 4 200 305 -12.4 0.1 -11.9 -12.7 02/23/2006 13:10:00 4.7 0.4 5.7 3.8 4.8 0.4 5.7 3.4 195 4 202 305 -12.1 0 -11.7 -12.3 02/23/2006 13:20:00 4.9 0.4 6.1 4.2 4.9 0.4 6.1 3.8 196 5 200 305 -11.9 0 -11.7 -12.1 02/23/2006 13:30:00 3.9 0.5 4.9 2.6 3.9 0.6 5.3 2.3 190 7 186 305 -11.8 0 -11.5 -12.1 02/23/2006 13:40:00 4.9 0.4 5.7 3.8 5 0.3 5.7 4.2 193 4 196 305 -11.4 0.1 -11.1 -11.7 02/23/2006 13:50:00 4.4 0.9 6.5 2.3 5.1 0.6 6.5 3.8 183 11 193 305 -11 0 -10.9 -11.3 02/23/2006 14:00:00 5.1 1.6 8.8 2.6 5.8 1.3 9.1 2.6 164 13 150 305 -11.5 0.2 -11.3 -12.1 02/23/2006 14:10:00 7.9 1.2 9.9 3.4 8 1 9.5 4.9 150 8 140 305 -11.8 0 -11.7 -12.1 02/23/2006 14:20:00 8.5 0.5 9.5 6.1 8.6 0.4 9.5 7.6 150 5 143 305 -11.8 0.1 -11.5 -12.1 02/23/2006 14:30:00 8.5 0.7 10.3 5.7 8.4 0.5 9.9 6.8 153 4 156 305 -11.5 0 -11.3 -11.7 02/23/2006 14:40:00 9.2 0.7 10.3 5.3 9.4 0.6 10.7 7.6 149 5 151 305 -11.5 0 -11.3 -11.7 02/23/2006 14:50:00 9.8 0.5 11.5 6.8 9.7 0.6 11.1 7.6 147 2 148 305 -11.4 0 -11.3 -11.5 02/23/2006 15:00:00 9.9 0.7 11.5 6.5 9.8 0.6 11.5 8 149 5 154 305 -11.1 0 -10.9 -11.3 02/23/2006 15:10:00 9.7 1 11.5 5.3 9.7 0.6 11.1 7.2 152 5 152 305 -10.9 0.1 -10.7 -11.3 02/23/2006 15:20:00 10 1.1 12.6 5.7 10 0.6 11.5 7.6 153 4 155 305 -10.8 0 -10.7 -10.9 02/23/2006 15:30:00 8.7 1.3 11.1 4.9 9.4 0.6 11.1 8 156 7 149 305 -10.5 0.1 -9.8 -10.9 02/23/2006 15:40:00 7.2 1 10.3 4.9 9.9 0.5 11.5 8.4 164 5 161 305 -9.9 0 -9.2 -10.2 02/23/2006 15:50:00 7.6 1.1 11.1 5.3 10.3 0.4 11.5 8.8 164 5 159 305 -9.8 0 -9.4 -10 02/23/2006 16:00:00 10.4 1.2 13 6.8 10.7 0.7 12.6 8.8 155 6 157 305 -10.1 0.2 -9.4 -10.4 02/23/2006 16:10:00 10.4 1.2 13.3 7.2 11.6 0.8 13.7 8.4 158 6 155 305 -9.7 0.1 -9.2 -10.2 02/23/2006 16:20:00 9.5 1.2 12.6 6.5 10.6 0.8 13 8.8 158 6 150 305 -9.7 0.1 -9.2 -10 02/23/2006 16:30:00 9.7 1.2 12.6 5.3 10.7 0.7 12.6 8.4 158 5 148 305 -9.9 0 -9.6 -10.2 02/23/2006 16:40:00 10.7 0.9 13 7.6 10.5 0.7 12.2 8.4 152 4 152 305 -10.3 0 -9.8 -10.4 02/23/2006 16:50:00 10.2 1 12.6 6.8 10.4 0.6 12.6 8.8 154 5 147 305 -10.2 0.1 -9.8 -10.4 02/23/2006 17:00:00 10.3 0.8 12.2 7.6 10.1 0.7 11.5 7.2 152 5 152 305 -10.1 0 -9.8 -10.2 02/23/2006 17:10:00 11.3 0.8 13 8.8 11 0.7 12.6 9.1 152 5 152 305 -9.9 0.1 -9.4 -10.2 02/23/2006 17:20:00 11 0.8 13.7 7.6 10.6 0.7 12.6 8.8 152 5 155 305 -9.8 0 -9.4 -9.8 02/23/2006 17:30:00 11.2 0.8 13.7 8.8 10.9 0.7 13.7 9.1 150 6 141 305 -9.7 0.1 -9.2 -9.8 02/23/2006 17:40:00 11.5 1 14.5 8 11.3 0.9 13.7 8.8 150 5 160 305 -10 0 -9.6 -10.2 02/23/2006 17:50:00 11.9 0.8 14.5 8.4 11.6 0.8 13.3 9.1 147 5 152 305 -9.9 0 -9.6 -10 02/23/2006 18:00:00 11.9 0.8 13.7 9.9 11.6 0.7 13.7 9.1 148 5 163 305 -9.8 0 -9.6 -10 02/23/2006 18:10:00 13.3 1.3 15.6 9.9 12.8 1.2 15.3 9.9 145 6 135 305 -9.7 0.1 -9.2 -9.8 02/23/2006 18:20:00 12.1 0.8 14.5 9.1 11.6 0.9 13.7 8.8 147 4 144 305 -9.3 0 -9 -9.6 02/23/2006 18:30:00 11.8 0.9 13.7 9.1 11.3 0.8 14.1 8.8 148 5 138 305 -8.9 0 -8.8 -9.2 02/23/2006 18:40:00 12.1 1 14.5 9.1 11.5 0.9 13.7 9.1 145 5 140 305 -8.7 0 -8.4 -8.8 02/23/2006 18:50:00 12.5 0.8 14.9 10.3 12 0.8 14.1 9.1 145 4 143 305 -8.4 0 -8.2 -8.6 02/23/2006 19:00:00 12.7 1 14.9 9.1 12.2 0.8 14.5 8.8 145 5 141 305 -8.2 0 -7.9 -8.4 02/23/2006 19:10:00 13.2 0.7 15.6 11.5 12.5 0.7 14.9 10.7 142 3 143 305 -7.9 0 -7.7 -8.2 02/23/2006 19:20:00 12.5 0.8 14.1 9.9 12.1 0.7 13.3 10.3 141 4 141 305 -7.8 0 -7.7 -7.9 02/23/2006 19:30:00 11.4 1.1 14.1 7.2 11.1 1.1 14.1 8 148 6 147 305 -7.5 0.1 -7.1 -7.9 02/23/2006 19:40:00 13 1.3 16.1 9.1 12.5 1.2 15.3 9.5 149 5 151 305 -6.8 0.2 -6.4 -7.3 02/23/2006 19:50:00 13.5 1.1 16.4 9.9 13 1 15.6 10.3 149 5 148 305 -6.3 0.1 -6 -6.7 02/23/2006 20:00:00 14 1.2 16.4 10.7 13.4 1.1 15.6 9.9 149 5 143 305 -5.9 0.1 -5.6 -6.2 02/23/2006 20:10:00 14 1.3 17.2 10.7 13.3 1.2 16.1 10.7 147 6 148 305 -5.7 0 -5.6 -5.8 02/23/2006 20:20:00 13.3 1.5 17.6 9.9 12.8 1.3 16.4 9.5 147 7 154 305 -5.5 0 -5.3 -5.8 02/23/2006 20:30:00 13.8 1.2 16.4 10.3 13.2 1.1 15.6 9.9 148 5 165 305 -5.5 0 -5.1 -5.6 02/23/2006 20:40:00 13.8 1 16.1 9.9 13.1 0.9 15.3 11.1 152 4 152 305 -5.2 0 -5.1 -5.3 02/23/2006 20:50:00 13.6 1 15.6 10.7 13 0.8 14.9 11.1 152 4 158 305 -5 0 -4.7 -5.3 02/23/2006 21:00:00 13.6 1.1 16.1 8.8 13.1 1 15.6 9.1 150 5 152 305 -4.8 0.1 -4.5 -5.1 02/23/2006 21:10:00 11.8 1.2 14.9 8.8 11.5 1 14.9 9.1 148 6 152 305 -4.9 0 -4.5 -5.1 02/23/2006 21:20:00 12.6 1.2 15.6 9.1 12.5 1.1 14.5 8.8 154 5 154 305 -4.2 0.2 -3.8 -4.7 02/23/2006 21:30:00 13 1.4 16.1 8 13 1.2 15.6 9.1 153 5 150 305 -3.9 0.1 -3.6 -4.5 02/23/2006 21:40:00 13.1 1.4 16.4 10.3 12.7 1.2 16.8 10.3 149 6 145 305 -4.7 0.1 -4.2 -5.1 02/23/2006 21:50:00 13.5 1 16.1 10.3 13.4 0.8 15.6 11.1 154 5 154 305 -4.5 0 -4.2 -4.7 02/23/2006 22:00:00 11.7 1.3 15.6 8 12.3 0.8 14.9 10.3 157 5 151 305 -4.3 0 -4 -4.5 02/23/2006 22:10:00 8.6 1.4 13 6.5 12 0.9 14.5 9.9 165 6 155 305 -3.7 0.3 -2.9 -4.2 02/23/2006 22:20:00 8.1 0.9 11.1 5.7 12.5 0.9 14.9 9.1 169 4 172 305 -2.6 0.1 -2.4 -3.1 02/23/2006 22:30:00 8.7 1 11.8 6.5 12.4 0.9 14.5 9.5 170 5 176 305 -2.4 0.2 -2 -2.7 02/23/2006 22:40:00 8.6 0.9 11.8 6.1 12.6 1 15.3 10.3 170 4 176 305 -2.2 0.2 -1.8 -2.7 02/23/2006 22:50:00 8.6 1.2 12.2 5.3 12.6 0.8 15.6 10.3 172 5 187 305 -1.8 0 -1.3 -2 02/23/2006 23:00:00 8.6 1.3 12.6 5.7 12.6 0.8 14.5 10.7 173 5 174 305 -1.8 0 -1.8 -2 02/23/2006 23:10:00 8.8 1.2 11.8 5.7 12.2 0.9 14.5 9.5 173 6 184 305 -1.6 0 -1.1 -1.8 02/23/2006 23:20:00 9.1 1.2 12.2 6.5 12 0.9 14.9 9.1 174 6 183 305 -1.6 0 -1.1 -1.8 02/23/2006 23:30:00 8.6 1.3 13 5.7 11.7 0.8 14.1 9.5 174 5 182 305 -1.5 0 -1.1 -1.8 02/23/2006 23:40:00 8.5 1.6 12.2 4.9 11.1 0.8 13 9.1 176 6 189 305 -1.5 0 -1.1 -1.5 02/23/2006 23:50:00 8.7 1.4 12.2 4.9 10.7 0.9 13 8.8 177 5 182 305 -1.5 0 -1.1 -1.8 02/24/2006 00:00:00 9 1.3 11.8 4.9 10.6 0.8 12.2 8.4 179 4 183 305 -1.5 0 -1.1 -1.8 02/24/2006 00:10:00 9.1 1.2 11.1 4.9 10.4 0.7 12.2 7.6 179 4 179 305 -1.6 0 -1.1 -1.8 02/24/2006 00:20:00 7.4 1.3 11.1 4.2 9.2 1 11.8 6.8 177 5 186 305 -1.6 0 -1.3 -1.8 02/24/2006 00:30:00 7.1 1.2 9.5 4.2 8.6 0.7 10.7 6.5 178 5 173 305 -1.7 0 -1.3 -1.8 02/24/2006 00:40:00 8.5 0.5 9.5 6.1 8.8 0.5 9.9 7.6 183 3 177 305 -1.9 0 -1.8 -2 02/24/2006 00:50:00 8.2 0.4 9.1 6.8 8.4 0.3 9.1 7.6 184 2 186 305 -2 0 -1.8 -2 02/24/2006 01:00:00 8.1 0.4 9.1 6.8 8.4 0.4 9.5 7.6 184 2 179 305 -2 0 -1.8 -2 02/24/2006 01:10:00 7.9 0.4 8.8 6.8 8 0.4 9.1 6.8 185 2 188 305 -2 0 -1.8 -2 02/24/2006 01:20:00 7.6 0.4 8.8 6.8 7.7 0.4 8.8 6.8 186 3 186 305 -1.9 0 -1.8 -2 02/24/2006 01:30:00 7.6 0.4 8.8 6.5 7.6 0.5 8.4 5.7 187 2 190 305 -1.9 0 -1.8 -2 02/24/2006 01:40:00 7.6 0.4 8.8 6.8 7.4 0.4 8.4 6.1 189 3 192 305 -1.9 0 -1.8 -2 02/24/2006 01:50:00 7.3 0.4 8.4 6.1 7.1 0.5 8 5.7 190 3 194 305 -1.9 0 -1.8 -2 02/24/2006 02:00:00 7.3 0.4 8.4 6.5 7 0.4 8 6.1 190 3 192 305 -1.9 0 -1.8 -2 02/24/2006 02:10:00 7.2 0.5 8.4 5.7 6.9 0.5 8.4 5.3 191 3 193 305 -1.8 0 -1.8 -2 02/24/2006 02:20:00 7.4 0.4 8.4 6.5 7 0.5 8 5.3 192 3 189 305 -1.8 0 -1.8 -2 02/24/2006 02:30:00 7.5 0.4 8.4 6.1 7.2 0.5 8.4 5.3 192 3 192 305 -1.7 0 -1.8 -1.8 02/24/2006 02:40:00 7.5 0.5 8.8 6.5 7.2 0.5 8.8 4.9 190 3 192 305 -1.7 0 -1.8 -1.8 02/24/2006 02:50:00 7.8 0.5 9.5 6.8 7.5 0.5 9.1 5.7 192 3 196 305 -1.7 0 -1.8 -1.8 02/24/2006 03:00:00 7.9 0.4 8.8 6.8 7.5 0.5 9.1 6.1 193 3 188 305 -1.7 0 -1.3 -1.8 02/24/2006 03:10:00 8.2 0.4 9.5 6.8 7.8 0.5 8.8 6.1 195 3 197 305 -1.7 0 -1.5 -1.8 02/24/2006 03:20:00 8.2 0.4 9.1 7.2 7.8 0.5 8.8 6.5 195 3 194 305 -1.6 0 -1.3 -1.8 02/24/2006 03:30:00 8.4 0.5 10.3 7.2 8 0.5 9.9 6.5 196 3 201 305 -1.6 0 -1.1 -1.8 02/24/2006 03:40:00 8.9 0.5 10.7 7.6 8.6 0.5 9.9 6.8 197 3 201 305 -1.6 0.1 -1.1 -1.8 02/24/2006 03:50:00 9.7 0.5 11.5 8.4 9.4 0.5 10.7 7.6 196 3 196 305 -1.5 0 -1.3 -1.8 02/24/2006 04:00:00 9.7 0.5 11.1 8.4 9.2 0.5 10.7 7.2 196 3 194 305 -1.5 0 -1.1 -1.8 02/24/2006 04:10:00 9.9 0.5 11.5 8.8 9.5 0.6 11.1 7.6 198 3 198 305 -1.5 0 -1.3 -1.8 02/24/2006 04:20:00 9.3 0.5 10.7 8 8.9 0.5 10.3 6.5 200 3 201 305 -1.4 0 -1.1 -1.5 02/24/2006 04:30:00 9 0.6 10.3 7.2 8.6 0.6 10.3 6.8 200 3 200 305 -1.4 0 -1.3 -1.5 02/24/2006 04:40:00 8.3 0.5 9.5 6.8 8 0.6 9.5 5.7 204 4 210 305 -1.4 0 -1.1 -1.5 02/24/2006 04:50:00 7.9 0.6 9.5 6.1 7.4 0.7 8.8 5.7 207 4 208 305 -1.2 0 -0.8 -1.3 02/24/2006 05:00:00 8 0.6 9.5 6.8 7.5 0.6 9.1 6.1 205 4 203 305 -1.2 0 -0.8 -1.3 02/24/2006 05:10:00 8.2 0.6 10.3 5.7 7.7 0.7 9.5 5.7 206 4 204 305 -1.1 0 -1.1 -1.3 02/24/2006 05:20:00 7.9 0.6 9.9 5.7 7.3 0.8 9.1 5.3 209 4 211 305 -1.1 0 -1.1 -1.1 02/24/2006 05:30:00 8.1 0.7 9.9 6.5 7.6 0.8 9.5 5.7 212 4 214 305 -1.1 0 -1.1 -1.1 02/24/2006 05:40:00 8.2 0.6 9.9 6.1 7.6 0.7 9.5 5.3 211 5 210 305 -1.1 0 -0.8 -1.1 02/24/2006 05:50:00 8.1 0.6 10.7 6.5 7.4 0.7 9.5 5.7 211 5 215 305 -1.1 0 -0.8 -1.1 02/24/2006 06:00:00 7.7 0.6 9.5 6.1 7.2 0.7 9.1 4.9 211 4 208 305 -1 0.1 -0.4 -1.1 02/24/2006 06:10:00 7.5 0.5 8.8 6.1 6.9 0.6 8.4 4.9 211 5 213 305 -1 0.1 -0.4 -1.1 02/24/2006 06:20:00 7.8 0.5 8.8 6.1 7.1 0.6 8.8 4.9 211 4 210 305 -1 0 -0.8 -1.1 02/24/2006 06:30:00 7.4 0.6 8.8 5.3 6.8 0.7 8.4 4.6 211 4 208 305 -1 0 -0.8 -1.1 02/24/2006 06:40:00 6.9 0.6 8.8 5.3 6.4 0.7 8 4.6 211 4 210 305 -1 0 -0.8 -1.1 02/24/2006 06:50:00 6.7 0.5 7.6 4.9 6.1 0.6 8 4.6 211 5 224 305 -1 0 -0.6 -1.1 02/24/2006 07:00:00 6.1 0.5 7.6 4.6 5.6 0.6 7.2 4.2 212 5 214 305 -1 0 -0.8 -1.1 02/24/2006 07:10:00 5.9 0.5 7.6 4.6 5.4 0.6 7.2 3.8 213 5 221 305 -1 0 -0.8 -1.1 02/24/2006 07:20:00 5.7 0.6 7.6 4.6 5.3 0.6 7.2 3.4 214 5 207 305 -1 0 -0.6 -1.1 02/24/2006 07:30:00 5.7 0.5 7.2 4.6 5.2 0.5 6.5 3.8 216 4 225 305 -1 0 -0.6 -1.1 02/24/2006 07:40:00 6 0.6 7.6 4.9 5.4 0.6 7.6 4.2 221 5 224 305 -1 0.1 -0.6 -1.1 02/24/2006 07:50:00 5.5 0.7 8 4.2 5.1 0.7 7.2 3.4 218 6 224 305 -1 0 -0.6 -1.1 02/24/2006 08:00:00 5.6 0.5 6.8 4.2 5.1 0.6 6.8 3.4 218 6 226 305 -1.1 0 -0.6 -1.1 02/24/2006 08:10:00 5.7 0.6 7.6 4.2 5.2 0.6 7.2 3.8 220 5 215 305 -1.1 0 -0.8 -1.3 02/24/2006 08:20:00 5.6 0.5 7.2 4.2 5.1 0.5 6.5 3.8 215 5 221 305 -1.2 0 -1.1 -1.3 02/24/2006 08:30:00 5.4 0.5 6.8 4.2 4.9 0.5 6.1 3.4 212 4 223 305 -1.2 0 -0.6 -1.3 02/24/2006 08:40:00 5.8 0.6 8 4.6 5.4 0.7 7.2 3.4 217 6 225 305 -1.1 0 -0.6 -1.3 02/24/2006 08:50:00 5.7 0.6 7.6 4.2 5.3 0.6 6.8 3.4 215 5 218 305 -1.1 0 -0.8 -1.3 02/24/2006 09:00:00 6 0.6 8 4.6 5.6 0.6 7.2 3.8 215 4 212 305 -1.1 0 -1.1 -1.3 02/24/2006 09:10:00 5.6 0.5 7.2 4.2 5.2 0.5 6.8 4.2 218 5 224 305 -1.1 0 -0.6 -1.1 02/24/2006 09:20:00 6 0.9 8.4 4.2 5.6 0.9 8 4.2 217 5 224 305 -1.1 0 -0.6 -1.1 02/24/2006 09:30:00 7 0.9 9.5 4.9 6.4 1 9.1 4.2 223 5 228 305 -1.1 0 -0.6 -1.1 02/24/2006 09:40:00 6.6 0.8 9.5 4.6 6.1 0.8 8.8 4.6 223 6 221 305 -1 0 -0.6 -1.1 02/24/2006 09:50:00 5.5 0.8 8.4 3.8 5.1 0.7 8 3.4 217 6 233 305 -1 0 -0.8 -1.1 02/24/2006 10:00:00 5.8 0.6 8 4.6 5.3 0.7 7.2 3.8 218 6 224 305 -1 0 -0.8 -1.1 02/24/2006 10:10:00 6.2 0.7 8 4.6 5.8 0.7 8 3.8 215 5 222 305 -1 0 -0.8 -1.1 02/24/2006 10:20:00 5.9 0.6 7.6 4.2 5.4 0.8 7.2 3.4 208 4 212 305 -1 0 -0.8 -1.1 02/24/2006 10:30:00 6.4 0.6 8.4 4.6 6 0.7 8 4.2 208 5 208 305 -1 0 -0.8 -1.1 02/24/2006 10:40:00 6.3 0.5 8 4.9 6.1 0.6 7.6 4.6 205 5 210 305 -0.9 0 -0.8 -1.1 02/24/2006 10:50:00 7 0.6 8.8 5.3 6.8 0.7 8.8 5.3 211 5 214 305 -1 0 -0.8 -1.1 02/24/2006 11:00:00 6.5 0.6 8.4 5.3 6.1 0.7 8 3.8 212 5 210 305 -1 0 -0.8 -1.1 02/24/2006 11:10:00 5.9 0.5 7.2 4.6 5.6 0.5 6.5 4.2 205 4 208 305 -0.9 0 -0.6 -1.1 02/24/2006 11:20:00 6 0.5 7.2 4.9 5.8 0.5 7.2 4.2 204 4 198 305 -0.8 0 -0.6 -1.1 02/24/2006 11:30:00 6.5 0.5 8 5.7 6.3 0.5 7.6 4.9 203 3 202 305 -0.8 0 -0.6 -1.1 02/24/2006 11:40:00 6.7 0.5 8.4 5.7 6.6 0.5 8.4 5.3 202 4 192 305 -0.9 0 -0.6 -1.1 02/24/2006 11:50:00 6.5 0.5 8 5.3 6.2 0.6 7.6 4.6 205 4 203 305 -0.9 0 -0.8 -1.1 02/24/2006 12:00:00 6.5 0.4 8 4.9 6.3 0.5 8 4.6 203 3 198 305 -0.9 0 -0.6 -1.1 02/24/2006 12:10:00 6.9 0.6 8.4 5.7 6.7 0.6 8.4 4.9 204 4 197 305 -0.8 0 -0.4 -1.1 02/24/2006 12:20:00 7.2 0.5 8.8 5.7 7 0.6 8.4 4.9 205 4 210 305 -0.7 0 -0.4 -0.8 02/24/2006 12:30:00 7.4 0.6 9.1 5.7 7.2 0.7 9.1 4.9 203 4 198 305 -0.8 0 -0.4 -0.8 02/24/2006 12:40:00 8.2 0.6 9.9 6.8 7.9 0.6 9.1 6.1 205 4 208 305 -0.7 0 -0.6 -0.8 02/24/2006 12:50:00 8.5 0.6 10.3 6.8 8.3 0.7 10.3 6.5 205 3 203 305 -0.7 0 -0.1 -0.6 02/24/2006 13:00:00 8.8 0.7 10.7 7.2 8.6 0.8 10.3 6.1 203 4 206 305 -0.6 0 -0.1 -0.8 02/24/2006 13:10:00 9 0.6 10.7 7.6 8.8 0.6 10.7 7.2 203 3 205 305 -0.6 0 0.1 -0.6 02/24/2006 13:20:00 9.3 0.7 11.1 7.2 8.9 0.8 11.1 6.5 203 4 196 305 -0.5 0 0.1 -0.6 02/24/2006 13:30:00 9.5 0.7 11.5 6.5 9.3 0.8 11.1 6.5 202 4 208 305 -0.5 0.1 0.1 -0.6 02/24/2006 13:40:00 9.6 0.6 11.1 8.4 9.5 0.6 11.1 7.2 199 3 198 305 -0.4 0.1 0.1 -0.6 02/24/2006 13:50:00 9.4 0.5 11.1 8.4 9.2 0.6 10.7 7.2 197 3 205 305 -0.4 0.1 0.1 -0.6 02/24/2006 14:00:00 9.9 0.6 11.5 8.4 9.7 0.7 11.8 7.6 196 3 198 305 -0.4 0.1 0.1 -0.6 02/24/2006 14:10:00 9.9 0.6 11.5 8 9.6 0.7 11.5 7.6 196 3 193 305 -0.3 0.1 0.3 -0.4 02/24/2006 14:20:00 9.8 0.5 11.1 8.4 9.5 0.7 11.1 7.2 193 3 196 305 -0.3 0 0.1 -0.4 02/24/2006 14:30:00 9.8 0.6 11.5 8 9.5 0.7 11.5 6.8 192 3 197 305 -0.3 0 0.1 -0.4 02/24/2006 14:40:00 10 0.6 12.2 8.4 9.7 0.7 11.5 7.6 191 3 194 305 -0.3 0 0.3 -0.4 02/24/2006 14:50:00 10.3 0.6 11.8 8.8 10 0.7 11.8 8 192 3 194 305 -0.3 0 0.1 -0.4 02/24/2006 15:00:00 10.7 0.7 12.6 9.1 10.4 0.7 12.2 8.4 194 3 190 305 -0.4 0.1 0.3 -0.6 02/24/2006 15:10:00 10.5 0.6 12.2 8.8 10.2 0.7 11.8 7.6 193 3 195 305 -0.4 0.1 0.3 -0.4 02/24/2006 15:20:00 10.9 0.7 13 9.5 10.6 0.7 12.6 8.4 193 4 196 305 -0.4 0 0.3 -0.4 02/24/2006 15:30:00 11.3 0.7 13.3 9.5 11 0.8 13 8.4 193 3 194 305 -0.3 0.1 0.3 -0.4 02/24/2006 15:40:00 11.4 0.7 13 9.5 11.1 0.8 13 8.8 192 3 196 305 -0.4 0 0.1 -0.4 02/24/2006 15:50:00 11.5 0.7 13.3 9.5 11.2 0.8 13.3 8.8 193 3 197 305 -0.3 0 0.1 -0.4 02/24/2006 16:00:00 12 0.7 13.7 9.5 11.7 0.9 13.7 9.1 192 4 192 305 -0.3 0 0.1 -0.4 02/24/2006 16:10:00 13 0.7 14.9 11.1 12.7 0.9 14.9 9.9 194 4 194 305 -0.3 0 0.3 -0.4 02/24/2006 16:20:00 12.7 0.9 14.9 10.7 12.3 1 14.9 9.5 194 4 198 305 -0.3 0 0.3 -0.4 02/24/2006 16:30:00 13 0.7 15.3 11.1 12.8 0.9 14.9 9.9 192 3 190 305 -0.3 0 0.3 -0.4 02/24/2006 16:40:00 12.9 0.8 14.9 11.1 12.5 1 15.3 9.9 191 3 184 305 -0.3 0 0.3 -0.4 02/24/2006 16:50:00 13.4 0.9 16.8 9.9 12.9 1 16.1 9.1 191 3 192 305 -0.3 0 0.3 -0.4 02/24/2006 17:00:00 13.6 0.8 16.1 11.1 13.3 0.9 15.6 10.7 192 3 192 305 -0.3 0 0.3 -0.4 02/24/2006 17:10:00 13.8 0.8 16.1 11.8 13.4 1 15.6 9.5 193 3 189 305 -0.3 0 0.1 -0.4 02/24/2006 17:20:00 13.9 0.9 16.1 11.8 13.4 1 16.1 10.7 194 3 197 305 -0.2 0 0.3 -0.4 02/24/2006 17:30:00 14 1 16.8 11.5 13.6 1.1 16.4 9.9 195 4 188 305 -0.1 0 0.3 -0.4 02/24/2006 17:40:00 14.2 0.9 16.4 11.5 13.8 1 16.1 10.7 195 4 196 305 -0.1 0 0.3 -0.4 02/24/2006 17:50:00 14.5 0.8 17.2 11.8 14.1 0.9 16.8 11.5 197 3 197 305 -0.1 0 0.3 -0.4 02/24/2006 18:00:00 14.1 0.8 16.4 11.8 13.7 1 16.1 10.7 196 3 197 305 -0.1 0 0.3 -0.4 02/24/2006 18:10:00 14.6 1 17.2 12.2 14.1 1 16.8 11.1 195 4 203 305 -0.1 0 0.3 -0.4 02/24/2006 18:20:00 14.7 0.9 17.2 12.2 14.3 1 16.8 11.1 196 4 198 305 -0.1 0 0.3 -0.4 02/24/2006 18:30:00 15.1 1.1 18.7 12.6 14.6 1.2 17.6 11.5 199 4 205 305 -0.1 0 0.6 -0.4 02/24/2006 18:40:00 16.1 1.1 19.1 12.6 15.4 1.2 18.3 11.8 201 5 207 305 0 0 0.6 -0.4 02/24/2006 18:50:00 15.8 1.2 18.7 13 15.2 1.3 18.3 11.8 204 5 210 305 -0.1 0 0.6 -0.4 02/24/2006 19:00:00 16 1.4 19.1 11.8 15.3 1.4 18.7 11.1 205 5 199 305 -0.1 0 0.3 -0.4 02/24/2006 19:10:00 15.1 1.1 17.6 11.1 14.2 1.4 17.2 10.7 206 5 206 305 -0.1 0 0.3 -0.4 02/24/2006 19:20:00 14.7 1.4 17.9 9.5 13.8 1.6 17.9 9.1 206 4 208 305 -0.1 0 0.3 -0.4 02/24/2006 19:30:00 14.7 1.2 17.6 9.5 14 1.5 17.2 9.9 208 5 213 305 -0.1 0 0.3 -0.4 02/24/2006 19:40:00 14 1.3 17.2 10.3 13.3 1.6 17.6 9.1 207 5 208 305 -0.1 0 0.3 -0.4 02/24/2006 19:50:00 13.9 1.2 16.8 9.5 13.2 1.5 16.8 8.8 208 5 207 305 -0.1 0 0.3 -0.4 02/24/2006 20:00:00 14.2 1.1 17.6 11.5 13.6 1.3 17.6 10.3 209 4 211 305 0 0 0.3 -0.1 02/24/2006 20:10:00 14.3 1.1 17.9 11.8 13.8 1.3 17.2 10.7 209 4 204 305 -0.1 0 0.3 -0.1 02/24/2006 20:20:00 13.8 1.2 16.4 10.3 13.2 1.3 16.8 9.5 212 4 215 305 0 0 0.6 -0.1 02/24/2006 20:30:00 13.8 1.2 17.9 10.7 13.5 1.3 16.8 10.3 213 4 216 305 0 0 0.6 -0.1 02/24/2006 20:40:00 13.5 1 16.8 10.7 13 1.1 16.4 10.3 215 5 220 305 0 0 0.6 -0.1 02/24/2006 20:50:00 13.4 1.2 16.8 9.9 12.8 1.4 16.8 9.5 215 5 215 305 0 0 0.6 0.1 02/24/2006 21:00:00 15.1 2.6 22.9 9.5 14.3 2.7 22.6 9.1 228 12 221 305 -0.1 0.2 0.6 -0.6 02/24/2006 21:10:00 13.7 1.6 17.9 9.9 12.8 1.6 17.2 9.5 227 5 228 305 -0.9 0.2 -0.4 -1.3 02/24/2006 21:20:00 12.9 1.1 15.6 9.1 12.3 1.2 15.3 9.5 228 5 225 305 -1.4 0.1 -0.8 -1.8 02/24/2006 21:30:00 13.7 1.3 17.6 10.3 12.8 1.4 17.6 9.9 229 5 231 305 -1.7 0 -1.1 -2 02/24/2006 21:40:00 14.2 1.5 17.6 10.3 13.2 1.5 16.8 9.5 231 5 231 305 -2.2 0.2 -1.8 -2.7 02/24/2006 21:50:00 13.6 1.3 17.2 9.9 12.8 1.1 16.4 9.5 229 5 231 305 -2.7 0 -2.2 -2.9 02/24/2006 22:00:00 12.9 1.2 16.1 9.5 12.2 1.1 15.3 9.1 228 5 227 305 -3 0.1 -2.4 -3.3 02/24/2006 22:10:00 12.4 1 16.4 9.9 11.7 1.1 15.3 9.1 226 5 224 305 -3.2 0.1 -2.7 -3.3 02/24/2006 22:20:00 12.9 1.2 16.1 9.9 12 1.4 16.4 8.8 223 5 224 305 -3.3 0 -2.7 -3.3 02/24/2006 22:30:00 13.2 1.1 16.1 10.3 12.3 1.2 15.6 8.8 224 5 227 305 -3.2 0.1 -2.7 -3.3 02/24/2006 22:40:00 12.8 1.4 16.8 9.9 11.8 1.4 16.1 8.8 220 5 220 305 -3.1 0.1 -2.7 -3.3 02/24/2006 22:50:00 15.2 1.8 20.2 9.9 14.2 1.9 19.5 10.3 224 6 234 305 -3.1 0.1 -2.7 -3.3 02/24/2006 23:00:00 17.6 1.6 21.4 13 16.8 1.8 21.4 11.8 226 5 231 305 -3.7 0.1 -3.1 -4 02/24/2006 23:10:00 16.8 1.3 21 13 16 1.5 21 11.5 225 5 231 305 -4.1 0.1 -3.6 -4.5 02/24/2006 23:20:00 16.2 1.4 19.5 11.1 15.4 1.6 19.1 11.5 225 5 213 305 -4.3 0 -4 -4.5 02/24/2006 23:30:00 16.7 1.6 20.6 12.6 15.7 1.9 20.2 10.7 225 5 224 305 -4.5 0.1 -4 -4.9 02/24/2006 23:40:00 16.4 1.6 20.2 11.5 15.3 1.9 19.5 10.3 224 5 237 305 -4.9 0 -4.5 -5.1 02/24/2006 23:50:00 16.5 1.7 21 12.6 15.6 1.9 20.2 11.5 223 5 225 305 -4.9 0 -4.7 -4.9 02/25/2006 00:00:00 15.4 1.5 19.1 11.5 14.5 1.5 18.7 10.7 224 5 225 305 -5.1 0 -4.7 -5.3 02/25/2006 00:10:00 15.3 1.4 20.2 12.2 14.2 1.5 19.5 11.1 221 5 217 305 -5.3 0 -4.9 -5.6 02/25/2006 00:20:00 14.9 1.3 17.6 11.1 13.8 1.5 17.2 9.1 222 6 226 305 -5.5 0 -5.3 -5.8 02/25/2006 00:30:00 16.3 1.7 21 12.2 15.3 1.7 20.2 11.1 221 5 220 305 -5.8 0 -5.6 -6 02/25/2006 00:40:00 17.9 1.7 22.1 12.6 16.7 1.8 21.4 12.6 220 5 223 305 -5.9 0 -5.8 -6 02/25/2006 00:50:00 18.3 1.7 23.3 13.3 17.5 1.8 21.8 12.6 218 5 214 305 -5.8 0 -5.3 -6 02/25/2006 01:00:00 18.4 1.8 22.9 13 17.5 1.9 22.1 13.3 219 5 226 305 -5.8 0 -5.6 -6 02/25/2006 01:10:00 18.7 1.7 23.3 14.1 17.7 1.7 23.3 13.7 219 5 212 305 -5.7 0 -5.1 -5.8 02/25/2006 01:20:00 18.5 1.5 21.8 13.7 17.5 1.7 21.8 11.8 219 5 223 305 -5.8 0.1 -5.3 -6 02/25/2006 01:30:00 18.7 1.7 23.7 13.7 17.6 1.9 24.4 13 220 5 221 305 -5.8 0 -5.3 -6 02/25/2006 01:40:00 19.5 2.9 26.8 11.5 18.2 3.1 25.6 10.7 228 12 232 305 -5.8 0 -5.1 -6.2 02/25/2006 01:50:00 15.5 2 19.5 9.9 12.8 2.1 17.6 6.8 266 7 263 305 -7 0.2 -6.2 -7.5 02/25/2006 02:00:00 15.2 2.5 21.8 8 12.6 2.3 17.6 6.1 268 8 268 305 -7.5 0.1 -7.3 -7.7 02/25/2006 02:10:00 14.3 2.5 22.1 7.6 11.8 2.5 19.9 5.7 267 8 261 305 -7.7 0 -7.5 -7.7 02/25/2006 02:20:00 12.4 1.9 17.6 7.6 9.9 1.8 14.9 5.7 266 8 270 305 -7.7 0 -7.7 -7.9 02/25/2006 02:30:00 12.4 1.8 17.2 7.6 10.3 2.1 15.6 4.9 266 9 268 305 -7.7 0 -7.3 -7.7 02/25/2006 02:40:00 13 2.2 19.1 8.4 10.9 2.2 17.9 6.1 270 9 265 305 -7.9 0.1 -7.7 -8.2 02/25/2006 02:50:00 12.7 1.9 17.2 7.2 10.4 1.8 14.5 5.7 267 9 266 305 -8 0 -7.7 -8.2 02/25/2006 03:00:00 12.1 1.5 16.1 8 10 1.7 14.1 6.1 265 8 258 305 -8.2 0 -7.7 -8.4 02/25/2006 03:10:00 11.6 1.5 16.1 7.2 10.1 1.7 14.1 5.7 259 8 263 305 -8.3 0 -7.7 -8.4 02/25/2006 03:20:00 12.4 1.5 17.2 9.1 11.1 1.6 15.3 7.6 253 8 248 305 -8.5 0 -7.9 -8.6 02/25/2006 03:30:00 12.2 1.6 17.6 8.4 11.3 1.6 16.4 8 250 8 257 305 -8.5 0 -7.9 -8.8 02/25/2006 03:40:00 12.7 1.6 17.9 8.8 11.8 1.7 17.6 6.8 249 7 258 305 -8.4 0 -7.9 -8.6 02/25/2006 03:50:00 12.1 1.6 17.9 8.4 11.1 1.7 16.8 7.2 250 6 255 305 -8.2 0 -7.7 -8.4 02/25/2006 04:00:00 12.3 1.6 16.1 7.6 11.2 1.8 16.1 6.5 251 8 253 305 -8.2 0 -7.7 -8.4 02/25/2006 04:10:00 12.7 1.6 17.2 8 11.8 1.8 15.6 4.9 248 7 245 305 -8.4 0.2 -7.7 -8.8 02/25/2006 04:20:00 10.6 1.3 13.7 6.1 9.7 1.4 12.6 5.7 250 7 254 305 -8.6 0.1 -8.2 -8.8 02/25/2006 04:30:00 9.4 1.4 12.2 5.7 8.3 1.6 11.8 3.8 254 8 259 305 -8.6 0.1 -8.2 -8.8 02/25/2006 04:40:00 7.9 1.2 10.7 4.9 6.9 1.5 10.7 3.8 253 7 250 305 -8.6 0 -8.2 -8.8 02/25/2006 04:50:00 7.3 1 9.5 4.6 6.6 1.1 9.1 3.4 251 7 251 305 -8.6 0 -8.2 -8.8 02/25/2006 05:00:00 7.4 1.3 16.1 5.3 6.8 1.3 14.9 4.6 236 9 234 305 -8.4 0 -8.2 -8.6 02/25/2006 05:10:00 15.8 1.8 20.2 10.7 14.9 1.9 19.5 9.9 243 8 243 305 -7.4 0.2 -7.1 -8.2 02/25/2006 05:20:00 14.3 1.7 18.7 9.9 13.1 1.7 17.9 9.1 246 7 245 305 -7.5 0.1 -7.1 -7.7 02/25/2006 05:30:00 14.5 1.7 18.7 10.7 13.6 1.9 19.1 9.5 245 7 246 305 -7.6 0 -7.3 -7.7 02/25/2006 05:40:00 13.4 1.5 16.8 9.9 12.5 1.6 16.4 8.8 242 6 238 305 -7.9 0.1 -7.7 -8.2 02/25/2006 05:50:00 11.8 1.4 16.4 7.6 10.9 1.5 14.9 6.5 244 6 236 305 -8.2 0 -7.9 -8.2 02/25/2006 06:00:00 12.5 1.7 16.4 8.8 11.7 1.8 15.6 7.2 247 6 245 305 -8.2 0 -7.9 -8.4 02/25/2006 06:10:00 13.1 1.5 17.2 8.4 12.2 1.7 16.1 8 246 6 245 305 -8.3 0 -7.9 -8.6 02/25/2006 06:20:00 12.2 1.3 16.4 8.8 11.5 1.5 16.4 8.4 245 6 249 305 -8.5 0 -7.9 -8.6 02/25/2006 06:30:00 12 1.4 16.1 8.4 11.2 1.5 15.3 6.8 247 7 248 305 -8.5 0 -7.9 -8.8 02/25/2006 06:40:00 12 1.3 16.1 8 11.2 1.3 14.9 7.6 241 6 244 305 -8.7 0 -8.2 -8.8 02/25/2006 06:50:00 11.5 1.3 14.9 7.2 10.8 1.3 14.5 7.2 237 7 241 305 -8.8 0 -8.2 -9.2 02/25/2006 07:00:00 11.8 1.1 15.6 8.4 10.8 1.2 14.1 7.6 236 6 236 305 -9 0 -8.4 -9.2 02/25/2006 07:10:00 11.1 1.3 14.1 6.8 10.2 1.3 13 6.1 239 6 252 305 -8.9 0.1 -8.2 -9.2 02/25/2006 07:20:00 12.1 1.5 18.3 8.8 11.2 1.5 16.8 7.6 244 8 256 305 -8.6 0 -8.2 -8.8 02/25/2006 07:30:00 13.6 1.7 18.3 9.1 12.6 1.8 17.2 6.5 247 7 242 305 -8.4 0 -7.7 -8.6 02/25/2006 07:40:00 13.1 1.3 17.2 9.5 12.1 1.5 17.6 8 244 6 239 305 -8.4 0 -7.7 -8.6 02/25/2006 07:50:00 13.4 1.4 16.8 8.8 12.5 1.5 16.8 8.4 246 6 241 305 -8.3 0 -7.7 -8.4 02/25/2006 08:00:00 13 1.6 17.6 8.8 12.1 1.8 16.8 6.5 247 7 254 305 -8.2 0 -7.7 -8.4 02/25/2006 08:10:00 13.7 1.3 19.1 10.7 12.8 1.5 18.7 8.4 245 6 254 305 -8.2 0 -7.7 -8.2 02/25/2006 08:20:00 14.1 1.1 16.8 10.7 13.3 1.3 16.1 9.9 238 6 245 305 -8.2 0 -7.9 -8.4 02/25/2006 08:30:00 14.8 1.7 19.5 10.7 13.9 1.7 19.1 9.5 236 6 238 305 -8.4 0 -7.9 -8.6 02/25/2006 08:40:00 16.7 1.9 21.4 12.2 15.6 2.1 21 10.7 241 7 246 305 -8.4 0 -7.9 -8.6 02/25/2006 08:50:00 17.6 1.8 22.1 12.2 16.5 2 21 10.7 243 6 238 305 -8.3 0 -7.7 -8.4 02/25/2006 09:00:00 17.8 1.8 23.3 13.3 16.5 2 22.6 11.1 245 6 246 305 -8.2 0 -7.9 -8.4 02/25/2006 09:10:00 15.7 1.7 19.9 11.5 14.6 1.8 18.3 9.5 241 6 242 305 -8.3 0 -8.2 -8.4 02/25/2006 09:20:00 16.7 1.7 21.4 12.2 15.9 1.7 20.2 11.5 241 6 245 305 -8.3 0 -7.9 -8.4 02/25/2006 09:30:00 16 1.7 22.6 12.2 15 1.8 20.6 10.3 243 6 233 305 -8.2 0 -8.2 -8.4 02/25/2006 09:40:00 17.3 1.7 21 12.2 16.1 2 21.4 9.9 249 7 246 305 -8.2 0 -7.9 -8.4 02/25/2006 09:50:00 15.9 2.5 24.4 9.9 14 2.6 22.1 8.4 257 7 267 305 -8.3 0 -7.9 -8.4 02/25/2006 10:00:00 15 2.4 20.6 9.5 12.9 2.5 19.9 7.2 268 10 273 305 -8.5 0.3 -8.2 -9.2 02/25/2006 10:10:00 15.4 2.2 19.9 8 12.9 2.3 17.9 6.1 268 8 276 305 -9 0 -8.8 -9.2 02/25/2006 10:20:00 17.2 2.7 23.3 11.5 15.1 2.7 23.3 9.5 261 7 255 305 -9.1 0 -8.8 -9.2 02/25/2006 10:30:00 19.2 2.2 24.4 12.2 17 2.4 23.7 9.9 260 7 261 305 -9.1 0.1 -8.6 -9.2 02/25/2006 10:40:00 17.7 2.2 23.3 12.2 15.8 2.3 23.7 9.9 258 8 258 305 -9.3 0 -8.8 -9.4 02/25/2006 10:50:00 20.7 2.8 27.9 11.8 18.3 2.9 25.2 9.9 259 8 260 305 -9.3 0 -9.2 -9.4 02/25/2006 11:00:00 19.9 2.7 27.5 12.2 17.4 2.7 24.4 11.5 259 8 261 305 -9.3 0 -8.8 -9.6 02/25/2006 11:10:00 17.7 2.7 23.7 9.5 15.3 2.8 21.8 7.2 261 9 261 305 -9.3 0 -9.2 -9.4 02/25/2006 11:20:00 19 2.8 26.8 12.2 16.3 2.7 23.3 8.4 264 8 275 305 -9.5 0 -9.2 -9.6 02/25/2006 11:30:00 18.6 2.7 25.2 12.2 15.9 2.7 22.1 9.1 267 9 275 305 -9.6 0 -9 -9.6 02/25/2006 11:40:00 17.6 2.9 25.6 10.3 14.7 2.9 21.4 7.6 269 9 270 305 -9.6 0 -9.4 -9.6 02/25/2006 11:50:00 18.7 3.1 26 8.4 15.7 2.9 22.6 6.5 267 8 263 305 -9.6 0.1 -9.2 -9.8 02/25/2006 12:00:00 18.3 3.1 25.6 9.9 15.4 2.8 22.9 8.4 267 9 261 305 -9.6 0 -9.4 -9.8 02/25/2006 12:10:00 17.8 2.9 25.2 9.9 15 2.9 22.1 8.4 270 9 268 305 -9.5 0 -9.2 -9.6 02/25/2006 12:20:00 16.8 2.5 22.1 9.5 14.1 2.4 19.9 7.6 269 9 273 305 -9.5 0 -9.2 -9.6 02/25/2006 12:30:00 17.4 2.7 24 11.5 14.9 2.7 20.6 8.4 272 9 275 305 -9.4 0 -9.2 -9.6 02/25/2006 12:40:00 18.2 2.7 26 12.2 15.7 2.8 22.1 8 271 9 265 305 -9.5 0 -9.2 -9.6 02/25/2006 12:50:00 16.1 2.6 21.8 9.1 13.6 2.5 19.5 6.8 272 9 269 305 -9.6 0 -9.2 -9.8 02/25/2006 13:00:00 16.8 2.6 22.6 9.9 14.2 2.6 22.1 7.6 270 8 285 305 -9.4 0 -9.2 -9.6 02/25/2006 13:10:00 16.6 2.6 22.1 9.9 14 2.3 18.7 8 269 8 266 305 -9.5 0.1 -9.2 -9.8 02/25/2006 13:20:00 18.6 2.6 24 11.1 15.7 2.5 21.8 9.9 270 8 265 305 -9.4 0 -9.2 -9.6 02/25/2006 13:30:00 16.8 3.1 24.8 10.3 14 2.8 21 7.2 270 9 269 305 -9.5 0 -9.2 -9.6 02/25/2006 13:40:00 15.1 2.4 20.2 9.5 13.1 2.4 19.5 7.6 274 9 273 305 -9.5 0 -9.2 -9.6 02/25/2006 13:50:00 15.9 2 21.4 10.3 13.8 2 19.5 7.6 273 8 274 305 -9.6 0 -9.2 -9.8 02/25/2006 14:00:00 16.5 2.3 24 11.5 13.8 2.3 21.8 7.6 271 8 270 305 -9.6 0.1 -9.2 -9.8 02/25/2006 14:10:00 15.8 2.6 22.1 9.1 13.2 2.5 19.9 6.8 269 9 269 305 -9.6 0 -9.2 -9.8 02/25/2006 14:20:00 16.7 2.6 22.9 10.7 14 2.5 20.6 8.4 270 8 252 305 -9.7 0.1 -9.4 -10 02/25/2006 14:30:00 16.8 2.7 22.1 9.5 14.2 2.6 20.2 6.5 271 9 280 305 -9.7 0 -9.4 -10 02/25/2006 14:40:00 17.5 2.6 23.3 10.7 14.9 2.5 21 8 271 9 268 305 -9.6 0 -9.2 -9.6 02/25/2006 14:50:00 16.2 2.8 22.9 9.1 13.7 2.7 20.6 8.4 270 8 275 305 -9.6 0 -9.2 -9.6 02/25/2006 15:00:00 16.6 2.5 22.1 9.5 14.1 2.4 20.2 7.6 270 8 270 305 -9.7 0.1 -9.2 -10 02/25/2006 15:10:00 15.9 2.6 21.4 9.1 13.6 2.5 19.5 8 268 9 275 305 -9.9 0 -9.6 -10 02/25/2006 15:20:00 16.9 2.3 24 11.1 14 2.5 21 7.2 270 8 264 305 -10.1 0 -9.8 -10.4 02/25/2006 15:30:00 16 2.4 23.3 10.7 13.5 2.3 20.6 8.4 269 8 268 305 -10.2 0 -10 -10.4 02/25/2006 15:40:00 15.5 2.5 21.8 9.5 13 2.3 19.1 6.8 269 9 268 305 -9.9 0 -9.6 -10 02/25/2006 15:50:00 16.4 2.6 22.6 10.3 13.8 2.7 20.2 7.2 271 9 269 305 -9.8 0 -9.6 -10 02/25/2006 16:00:00 15.4 2.6 21.8 9.1 13 2.5 21 7.2 271 8 280 305 -9.8 0 -9.6 -10 02/25/2006 16:10:00 15.4 2.6 21 9.5 13 2.6 19.5 6.8 269 9 272 305 -9.9 0 -9.8 -10 02/25/2006 16:20:00 15.6 2.6 21.8 8.4 13.5 2.7 20.2 6.8 276 8 274 305 -9.9 0 -9.8 -10 02/25/2006 16:30:00 15.2 1.7 19.5 10.7 13.4 1.7 18.3 9.1 276 8 287 305 -9.9 0 -9.8 -10 02/25/2006 16:40:00 14.3 1.8 19.1 10.3 12.4 1.9 17.6 7.6 277 11 275 305 -10.1 0 -9.8 -10.2 02/25/2006 16:50:00 14.1 1.9 19.5 9.9 12.5 1.6 17.2 7.6 278 7 275 305 -10 0 -9.8 -10.2 02/25/2006 17:00:00 15 2 20.6 9.5 13.8 2.1 18.3 8.4 282 8 275 305 -10.2 0.1 -9.8 -10.4 02/25/2006 17:10:00 14.5 2.1 19.5 8.8 12.9 2.3 18.3 7.2 280 8 279 305 -10.3 0 -10.2 -10.4 02/25/2006 17:20:00 15.1 2.1 20.2 8.8 13.2 2.2 19.9 8 277 7 277 305 -10.3 0 -10.2 -10.4 02/25/2006 17:30:00 13.6 2.3 18.7 8.4 12.2 2.4 17.6 6.1 279 8 283 305 -10.4 0 -10.4 -10.7 02/25/2006 17:40:00 15 1.9 21 9.1 13.7 2 19.1 8.4 283 6 290 305 -10.8 0.1 -10.4 -11.1 02/25/2006 17:50:00 15.4 1.7 19.9 10.3 14 2 18.3 8.4 282 7 281 305 -11 0 -10.9 -11.3 02/25/2006 18:00:00 14.6 2.1 19.1 8.8 13.3 2 18.7 8.8 280 7 287 305 -11.3 0.1 -10.9 -11.5 02/25/2006 18:10:00 11.2 1.7 15.6 6.8 10.2 1.7 14.9 6.1 282 9 283 305 -11.4 0 -11.3 -11.7 02/25/2006 18:20:00 12.4 2 17.2 8 11.7 1.9 16.4 8 285 7 282 305 -11.5 0 -11.5 -11.7 02/25/2006 18:30:00 13.1 1.9 20.6 8.4 12 2 20.6 6.5 282 7 280 305 -11.7 0 -11.5 -11.9 02/25/2006 18:40:00 13.9 1.9 18.3 7.6 12.5 2 17.6 6.8 280 8 272 305 -11.8 0.1 -11.7 -12.1 02/25/2006 18:50:00 11.5 2.3 16.8 7.2 10 2.4 16.1 5.7 275 8 285 305 -12 0 -11.7 -12.1 02/25/2006 19:00:00 10.9 1.9 16.8 5.7 9.3 1.9 14.5 5.7 269 10 277 305 -12.1 0 -12.1 -12.3 02/25/2006 19:10:00 11.4 1.7 16.1 7.6 9.5 1.7 14.1 5.3 268 9 278 305 -12.3 0 -12.1 -12.5 02/25/2006 19:20:00 12.6 1.8 17.2 8 10.6 1.7 14.9 6.1 269 9 273 305 -12.4 0 -12.3 -12.5 02/25/2006 19:30:00 12.2 1.7 15.6 6.1 10.3 1.7 14.5 4.6 271 8 287 305 -12.5 0 -12.3 -12.5 02/25/2006 19:40:00 10 1.7 14.5 5.3 8.4 1.8 13 4.2 270 9 271 305 -12.6 0 -12.5 -12.9 02/25/2006 19:50:00 10.1 1.3 13.3 6.1 8.4 1.3 12.2 5.3 268 8 269 305 -12.8 0 -12.5 -12.9 02/25/2006 20:00:00 9.4 1.5 13 5.3 7.9 1.5 11.1 3.4 271 9 269 305 -12.8 0 -12.5 -12.9 02/25/2006 20:10:00 9.3 2.1 15.3 4.6 7.7 2 13 3.4 269 8 265 305 -12.8 0 -12.5 -13.1 02/25/2006 20:20:00 10.3 1.7 14.5 6.1 8.7 1.7 13 4.6 270 9 277 305 -12.9 0 -12.7 -13.1 02/25/2006 20:30:00 10.8 1.6 14.9 6.8 9.1 1.7 14.5 4.6 271 8 275 305 -12.9 0 -12.9 -13.1 02/25/2006 20:40:00 11.2 1.6 14.5 7.2 9.2 1.7 13.3 4.6 270 8 268 305 -13 0 -12.9 -13.1 02/25/2006 20:50:00 12.4 2.2 17.9 8 10.6 2.2 16.4 5.3 272 9 291 305 -13 0 -12.9 -13.3 02/25/2006 21:00:00 13.9 1.8 19.9 8 12.2 2 18.3 6.8 278 12 284 305 -13.1 0 -12.9 -13.3 02/25/2006 21:10:00 13.1 2 17.6 7.6 11.4 2.1 15.6 6.1 277 8 276 305 -13.2 0 -13.1 -13.3 02/25/2006 21:20:00 12.7 2 17.6 8.4 11.3 2 15.6 6.1 278 7 277 305 -13.3 0 -13.1 -13.5 02/25/2006 21:30:00 12.8 1.6 17.9 8.4 11.5 1.7 16.1 7.2 281 8 280 305 -13.4 0 -13.3 -13.5 02/25/2006 21:40:00 12.8 1.7 16.4 8.4 11.7 1.9 15.6 6.1 282 7 284 305 -13.4 0 -13.3 -13.5 02/25/2006 21:50:00 12.8 1.2 15.6 9.5 11.6 1.4 14.9 7.6 281 6 276 305 -13.4 0 -13.3 -13.5 02/25/2006 22:00:00 13 1.9 17.6 8.4 11.7 2 17.2 6.8 280 8 283 305 -13.4 0 -13.3 -13.5 02/25/2006 22:10:00 12.2 2 18.3 8 10.6 2 17.9 6.1 277 8 272 305 -13.4 0 -13.3 -13.7 02/25/2006 22:20:00 9.9 1.5 13.7 6.1 8.4 1.5 13 4.9 272 9 283 305 -13.5 0 -13.3 -13.7 02/25/2006 22:30:00 9.1 1.3 13 6.5 7.6 1.4 11.5 3.8 264 9 275 305 -13.7 0 -13.5 -14.1 02/25/2006 22:40:00 9.7 1.3 13.3 5.7 8 1.3 12.6 4.9 266 8 264 305 -13.9 0 -13.7 -14.1 02/25/2006 22:50:00 9.6 1.2 12.2 6.1 7.8 1.3 11.1 4.2 265 8 265 305 -14 0 -13.7 -14.3 02/25/2006 23:00:00 9.8 1.2 12.2 6.8 8 1.3 11.5 4.9 264 6 258 305 -14 0 -13.9 -14.3 02/25/2006 23:10:00 9.6 1 11.8 7.2 8.2 1.2 10.7 4.9 261 7 259 305 -14.1 0 -13.9 -14.3 02/25/2006 23:20:00 9.5 1.3 13 6.5 8.2 1.5 11.8 4.6 261 6 261 305 -14.1 0 -13.9 -14.3 02/25/2006 23:30:00 9.9 1.3 12.6 5.3 8.6 1.3 12.2 4.9 259 7 259 305 -14.1 0 -13.9 -14.3 02/25/2006 23:40:00 9.5 1.1 12.6 5.7 8.2 1.3 11.5 4.6 258 7 258 305 -14.1 0 -13.9 -14.3 02/25/2006 23:50:00 10 1.3 13 5.7 8.7 1.5 12.2 5.3 259 7 261 305 -14.1 0 -13.9 -14.3 02/26/2006 00:00:00 9.9 1.2 12.6 6.5 8.6 1.5 12.2 4.6 257 7 254 305 -14.1 0 -13.7 -14.3 02/26/2006 00:10:00 10.1 1 12.6 7.2 9 1.2 12.6 5.7 256 7 259 305 -14.1 0 -13.7 -14.3 02/26/2006 00:20:00 9.8 1.1 12.6 7.2 8.4 1.3 11.8 4.6 257 7 253 305 -14.1 0 -13.9 -14.3 02/26/2006 00:30:00 8.7 1.1 11.5 5.7 7.7 1.2 10.7 3.8 253 8 264 305 -14.2 0 -13.9 -14.3 02/26/2006 00:40:00 8 1.2 11.8 5.7 7.1 1.3 10.7 4.6 252 8 242 305 -14.3 0 -13.7 -14.4 02/26/2006 00:50:00 7 0.8 9.5 4.9 6.2 0.9 9.1 3.8 247 8 250 305 -14.5 0.1 -14.3 -14.6 02/26/2006 01:00:00 6.6 0.9 8.8 4.2 5.9 0.9 8 3.8 245 7 242 305 -14.7 0 -14.3 -14.8 02/26/2006 01:10:00 6.8 0.8 8.8 4.6 6 0.9 8.8 3.8 251 8 254 305 -14.6 0.1 -14.1 -14.6 02/26/2006 01:20:00 7.1 0.8 9.5 5.3 6.3 1 9.1 3.8 253 7 256 305 -14.5 0 -14.1 -14.6 02/26/2006 01:30:00 7.7 0.8 9.9 5.7 6.8 1 9.1 3.8 254 6 252 305 -14.5 0 -14.3 -14.6 02/26/2006 01:40:00 8.2 1 10.7 5.3 7.1 1.2 9.9 4.2 255 7 261 305 -14.4 0 -14.3 -14.6 02/26/2006 01:50:00 7.5 0.8 10.3 4.9 6.3 0.9 9.5 4.2 260 7 253 305 -14.4 0 -14.1 -14.6 02/26/2006 02:00:00 8.6 1.2 11.8 5.7 7.2 1.3 10.3 3.8 262 7 263 305 -14.4 0 -14.3 -14.6 02/26/2006 02:10:00 8.6 1.1 11.5 5.7 7.4 1.2 10.3 4.6 259 8 254 305 -14.4 0 -14.1 -14.6 02/26/2006 02:20:00 8.5 1.1 11.5 4.6 7.4 1.1 11.1 3.8 256 7 268 305 -14.6 0.1 -14.3 -14.6 02/26/2006 02:30:00 8.1 1 10.7 4.9 6.9 1.2 10.3 3.4 259 7 256 305 -14.7 0 -14.3 -14.6 02/26/2006 02:40:00 8 0.9 10.3 4.9 6.8 1 9.9 3.8 257 8 258 305 -14.7 0 -14.3 -14.8 02/26/2006 02:50:00 7.7 0.8 9.5 5.3 6.9 0.8 9.1 4.6 251 6 252 305 -14.9 0 -14.3 -15 02/26/2006 03:00:00 7.5 0.7 9.5 5.7 6.7 0.8 8.8 4.9 247 9 253 305 -15 0.2 -14.3 -15.6 02/26/2006 03:10:00 8.2 0.8 10.3 5.7 7.4 0.8 9.5 4.9 244 7 252 305 -15.4 0 -14.8 -15.6 02/26/2006 03:20:00 8.3 1 10.7 4.9 7.4 1 9.9 4.2 251 6 258 305 -15.2 0 -14.6 -15.2 02/26/2006 03:30:00 8.2 1 10.7 5.3 7.3 1.1 9.9 4.9 251 7 258 305 -15.2 0 -15 -15.2 02/26/2006 03:40:00 8 0.9 10.3 4.9 7.3 0.9 9.5 4.6 247 6 251 305 -15.3 0 -15 -15.4 02/26/2006 03:50:00 7.2 0.8 9.1 4.9 6.4 0.8 8.8 4.6 240 5 239 305 -15.6 0.1 -15.2 -15.8 02/26/2006 04:00:00 7.3 0.7 9.1 5.3 6.6 0.7 8.4 4.6 244 6 250 305 -15.8 0 -15.2 -15.8 02/26/2006 04:10:00 7.4 0.7 9.9 4.9 6.6 0.8 8.4 4.2 245 6 249 305 -15.8 0 -15 -16 02/26/2006 04:20:00 7.4 0.9 10.3 5.3 6.7 1 9.5 4.6 249 7 244 305 -15.7 0.1 -15.2 -15.8 02/26/2006 04:30:00 8 0.8 9.9 6.1 7.1 1 9.5 4.2 253 6 261 305 -15.5 0 -14.8 -15.6 02/26/2006 04:40:00 7.6 0.9 9.9 5.7 6.8 0.9 9.5 4.6 246 6 251 305 -15.7 0.1 -14.8 -16 02/26/2006 04:50:00 7.3 0.7 9.1 5.3 6.5 0.8 9.5 4.9 246 6 248 305 -15.8 0 -15.2 -16 02/26/2006 05:00:00 6.5 0.7 8.4 4.6 5.7 0.7 8 4.2 240 6 247 305 -16.3 0.1 -15.6 -16.6 02/26/2006 05:10:00 7.2 0.6 9.5 6.1 6.2 0.6 8.8 4.6 242 5 242 305 -16.4 0 -16.2 -16.6 02/26/2006 05:20:00 6.8 0.8 9.5 4.6 6.1 0.8 8.4 3.8 249 6 249 305 -16.3 0 -16 -16.6 02/26/2006 05:30:00 7.1 0.9 9.9 4.9 6.1 0.8 8.8 4.2 255 7 259 305 -15.9 0.1 -15.8 -16.2 02/26/2006 05:40:00 6.9 0.7 9.1 5.3 6 0.8 8.4 3 249 9 259 305 -15.9 0.1 -15.6 -16.4 02/26/2006 05:50:00 7.2 0.6 8.8 4.9 6.5 0.7 8.4 4.9 237 5 242 305 -16.5 0.1 -16.2 -16.9 02/26/2006 06:00:00 7.1 0.5 8.8 5.7 6.3 0.5 7.6 4.9 237 5 245 305 -16.9 0 -16.4 -16.9 02/26/2006 06:10:00 7.7 0.8 9.9 6.1 6.8 0.9 9.5 4.9 243 7 246 305 -16.7 0.1 -16.4 -16.9 02/26/2006 06:20:00 7.9 1.1 10.7 4.9 6.8 1 9.9 4.2 256 7 266 305 -16.2 0.1 -15.8 -16.6 02/26/2006 06:30:00 7.3 0.9 10.3 4.9 6.2 1 8.8 3.4 258 7 258 305 -16.2 0 -15.8 -16.4 02/26/2006 06:40:00 7 0.8 8.8 4.9 6.1 0.9 8.4 3.8 250 7 250 305 -16.4 0 -16 -16.6 02/26/2006 06:50:00 7 1 9.5 4.2 6.1 1 9.5 3.4 255 7 264 305 -16.5 0 -16.2 -16.6 02/26/2006 07:00:00 7.2 1 9.5 4.6 5.8 1 8.8 3.4 262 7 268 305 -16.3 0 -16 -16.4 02/26/2006 07:10:00 6.6 0.8 9.1 4.9 5.6 0.7 8 4.2 257 8 272 305 -16.3 0 -16.2 -16.6 02/26/2006 07:20:00 5.8 0.6 7.2 4.2 4.9 0.6 6.5 3.4 247 6 251 305 -16.7 0.1 -16.4 -16.9 02/26/2006 07:30:00 5.1 0.5 6.5 4.2 4.5 0.5 6.1 3.4 245 5 250 305 -17 0.1 -16.9 -17.3 02/26/2006 07:40:00 5.4 0.5 6.8 4.2 4.7 0.5 5.7 3.4 243 6 248 305 -17.3 0.1 -16.9 -17.5 02/26/2006 07:50:00 4.8 0.4 6.1 3.4 4.3 0.5 5.7 3 239 7 244 305 -17.7 0.1 -16.9 -18.1 02/26/2006 08:00:00 4.3 0.5 6.5 3 3.9 0.5 5.3 2.6 237 8 221 305 -18 0.1 -17.5 -18.2 02/26/2006 08:10:00 4.9 0.7 6.8 3.4 4.2 0.7 6.5 3 247 12 267 305 -18 0.2 -17.1 -18.2 02/26/2006 08:20:00 5.8 0.6 8 4.2 4.8 0.7 6.8 2.6 256 7 270 305 -17 0.1 -16.4 -17.5 02/26/2006 08:30:00 4.4 0.9 6.5 2.3 3.8 0.8 5.7 1.5 240 11 248 305 -17.5 0.3 -16.6 -18.1 02/26/2006 08:40:00 3.9 0.6 5.7 2.3 3.3 0.4 4.6 2.3 242 12 254 305 -18.1 0.1 -17.5 -18.2 02/26/2006 08:50:00 5.3 1 8 3 4.4 1 6.8 1.9 258 7 263 305 -17.4 0.4 -16.6 -18.1 02/26/2006 09:00:00 6.5 0.7 8.8 4.6 5.5 0.7 7.6 3.4 258 6 250 305 -16.9 0 -16.4 -16.9 02/26/2006 09:10:00 7 1 9.9 4.9 6 1.2 9.9 3 256 7 268 305 -16.9 0 -16.9 -16.9 02/26/2006 09:20:00 8.5 1.7 12.2 4.6 7.2 1.7 11.8 3.8 271 11 266 305 -16.8 0.1 -16.4 -16.9 02/26/2006 09:30:00 6.9 1.3 11.1 3.8 5.7 1.5 9.9 3.4 265 9 285 305 -16.7 0.1 -16.2 -16.9 02/26/2006 09:40:00 6.4 0.8 8.8 4.2 5.5 0.9 8 3 257 7 262 305 -16.9 0 -16.7 -17.1 02/26/2006 09:50:00 6.7 0.7 8.8 4.9 5.7 0.7 7.6 4.2 249 7 251 305 -17.2 0.1 -16.9 -17.5 02/26/2006 10:00:00 4.5 0.8 6.8 2.6 4.1 0.7 5.7 2.6 227 9 246 305 -18.4 0.5 -16.9 -19 02/26/2006 10:10:00 6.2 0.5 7.6 4.6 5.7 0.5 6.8 4.2 224 7 226 305 -18.9 0.1 -18.4 -19 02/26/2006 10:20:00 5.7 0.5 8 4.2 5 0.5 6.8 3.8 230 5 234 305 -19.1 0.1 -18.4 -19.3 02/26/2006 10:30:00 6.2 0.6 7.6 4.6 5.3 0.7 6.8 3.8 233 6 238 305 -18.8 0.2 -18.2 -19 02/26/2006 10:40:00 6.1 0.7 7.6 4.2 5.4 0.7 6.8 3.4 236 7 246 305 -18.3 0.2 -17.7 -18.8 02/26/2006 10:50:00 4.6 0.6 6.8 3.4 3.9 0.6 6.8 2.6 237 9 244 305 -18.7 0.1 -18.1 -19 02/26/2006 11:00:00 5.7 1 8 3.4 4.8 0.9 7.2 3 253 10 265 305 -18 0.6 -16.9 -18.8 02/26/2006 11:10:00 6.5 1 9.1 4.2 5.4 1 8 3 259 8 265 305 -16.9 0 -16.4 -16.9 02/26/2006 11:20:00 6.8 0.8 9.1 4.2 5.7 0.9 7.6 3 260 8 268 305 -16.9 0 -16.6 -16.9 02/26/2006 11:30:00 7.3 0.9 10.3 4.6 5.9 1 8.4 3.4 264 7 257 305 -16.7 0.1 -16.6 -16.9 02/26/2006 11:40:00 7 0.9 9.1 4.2 5.7 1 8.4 3.4 263 8 258 305 -16.7 0 -16.6 -16.9 02/26/2006 11:50:00 7.2 1 9.5 4.2 5.9 1 8.4 2.3 263 6 264 305 -16.6 0 -16.6 -16.7 02/26/2006 12:00:00 7.7 1.2 10.3 4.2 6.3 1.2 9.5 3.4 265 6 268 305 -16.5 0 -16.4 -16.6 02/26/2006 12:10:00 8.3 1.1 11.5 4.9 7 1.1 9.5 3.8 264 7 268 305 -16.4 0 -16.4 -16.6 02/26/2006 12:20:00 8.3 1.2 11.1 4.9 7.1 1.4 10.7 3.8 263 6 260 305 -16.4 0 -16.2 -16.6 02/26/2006 12:30:00 8.8 1.3 11.8 5.7 7.4 1.2 11.1 4.2 264 6 268 305 -16.3 0 -16.2 -16.6 02/26/2006 12:40:00 9 1 11.1 6.5 7.5 1.1 10.3 3.8 264 6 264 305 -16.3 0 -16.2 -16.4 02/26/2006 12:50:00 8.6 1 10.7 5.7 7.2 1.1 9.5 4.9 265 6 256 305 -16.3 0 -16 -16.4 02/26/2006 13:00:00 8.5 1.2 11.1 4.9 7.3 1.2 10.3 3.4 263 6 261 305 -16.2 0 -16 -16.4 02/26/2006 13:10:00 7.5 1.2 10.7 4.6 6.2 1.3 9.9 3.4 271 11 287 305 -16 0 -15.8 -16.2 02/26/2006 13:20:00 9.2 1.1 11.5 6.8 8.1 1.1 10.7 5.7 279 6 281 305 -16.2 0 -16 -16.4 02/26/2006 13:30:00 8.7 1.1 11.5 5.3 7.4 1.1 9.9 4.2 274 8 269 305 -16.2 0 -16 -16.4 02/26/2006 13:40:00 8.6 1.5 11.5 4.6 7 1.5 10.3 3.8 271 8 268 305 -16.2 0 -16 -16.4 02/26/2006 13:50:00 8.6 1.3 11.5 4.9 7.5 1.2 11.1 4.2 278 15 252 305 -16.1 0 -16 -16.2 02/26/2006 14:00:00 9.7 1.1 12.2 5.7 8.9 1.2 11.5 4.9 283 6 287 305 -16.1 0 -15.8 -16.2 02/26/2006 14:10:00 9 1.2 12.2 6.1 7.5 1.2 10.7 3.8 272 9 271 305 -15.9 0 -15.6 -16 02/26/2006 14:20:00 8.4 1.5 12.6 4.9 7.1 1.5 11.1 3.8 271 8 275 305 -15.9 0 -15.6 -16.2 02/26/2006 14:30:00 9.3 1.4 11.8 5.3 8 1.5 11.5 4.2 272 8 273 305 -15.9 0 -15.8 -16.2 02/26/2006 14:40:00 9.8 1 12.2 6.8 8.2 1.2 11.1 4.9 269 7 271 305 -16.3 0.1 -16 -16.6 02/26/2006 14:50:00 9.5 1.3 12.6 4.9 8.1 1.4 11.5 4.2 271 7 262 305 -16.2 0 -16 -16.4 02/26/2006 15:00:00 8.4 1.2 10.7 5.3 6.8 1.3 9.9 3.8 271 8 270 305 -16.2 0 -16 -16.4 02/26/2006 15:10:00 9 1.2 11.8 5.7 7.7 1.4 11.1 4.6 273 7 269 305 -16.2 0 -16 -16.4 02/26/2006 15:20:00 8.5 1.2 11.1 5.3 7.1 1.3 9.9 3.8 270 8 275 305 -16.1 0 -15.8 -16.2 02/26/2006 15:30:00 8.7 1.3 11.5 5.7 7.1 1.3 10.3 3.8 270 8 272 305 -16.1 0.1 -15.8 -16.4 02/26/2006 15:40:00 9.3 1.4 12.2 5.7 7.7 1.4 10.7 4.6 267 8 265 305 -16.3 0 -16 -16.6 02/26/2006 15:50:00 9.6 1.2 11.8 5.7 7.8 1.2 11.1 3.8 269 8 268 305 -16.3 0 -16 -16.6 02/26/2006 16:00:00 9.8 1.4 12.2 5.7 7.8 1.3 11.1 3.8 266 7 255 305 -16.3 0 -16 -16.6 02/26/2006 16:10:00 10.2 1.1 12.6 6.5 8.4 1.1 10.7 4.9 269 6 270 305 -16.5 0 -16.2 -16.7 02/26/2006 16:20:00 9.5 1.4 12.6 6.1 8 1.5 11.8 4.9 274 9 278 305 -15.9 0.1 -15.6 -16.4 02/26/2006 16:30:00 10.3 1.2 13.7 7.6 9.1 1.3 13 6.5 277 7 285 305 -15.9 0 -15.8 -16.2 02/26/2006 16:40:00 10.6 1.3 13.3 6.8 9.7 1.4 13 6.1 282 8 285 305 -16.3 0.1 -16 -16.6 02/26/2006 16:50:00 9.6 1.2 13 6.8 8.8 1.3 12.6 5.7 283 8 283 305 -16.4 0.2 -16 -16.7 02/26/2006 17:00:00 9.2 1.7 12.6 4.9 7.9 1.7 12.6 4.2 272 9 282 305 -16.3 0 -16 -16.6 02/26/2006 17:10:00 8.5 1.5 11.8 5.3 7.3 1.5 11.1 3.8 275 9 264 305 -16.6 0.1 -16.4 -16.9 02/26/2006 17:20:00 9.6 1.2 12.2 6.1 8.6 1.3 11.8 5.7 282 7 289 305 -16.7 0.1 -16.4 -16.9 02/26/2006 17:30:00 8.3 1.7 13.3 3.8 7.4 1.7 12.2 3.8 280 8 292 305 -16.4 0.3 -16 -16.9 02/26/2006 17:40:00 9.8 1.3 12.6 6.8 8.4 1.5 12.2 4.9 275 7 273 305 -16.7 0.2 -16 -16.9 02/26/2006 17:50:00 8 1.3 11.1 4.9 6.4 1.3 9.9 3.4 270 9 259 305 -17.1 0.1 -16.9 -17.5 02/26/2006 18:00:00 9.2 1.2 12.2 5.7 7.5 1.4 12.2 4.6 270 9 271 305 -17.4 0 -16.9 -17.5 02/26/2006 18:10:00 10.6 1.2 13.7 7.2 9.8 1.4 12.6 6.5 283 6 274 305 -17.2 0.1 -16.9 -17.5 02/26/2006 18:20:00 9.1 1 12.2 6.8 8 1.3 12.2 4.6 279 7 290 305 -17.5 0 -17.1 -17.5 02/26/2006 18:30:00 9.8 1 11.8 7.2 9.3 1.1 11.5 6.5 286 5 273 305 -17.5 0 -16.9 -17.7 02/26/2006 18:40:00 9 1 11.5 6.5 8 1.2 10.7 4.9 283 7 280 305 -17.6 0 -17.1 -17.7 02/26/2006 18:50:00 8.8 1.4 11.5 4.9 8 1.6 11.1 4.2 284 11 284 305 -17.5 0 -17.1 -17.9 02/26/2006 19:00:00 9.8 1.1 12.2 6.8 9.3 1.3 12.2 6.1 290 7 287 305 -17.9 0.1 -17.5 -18.1 02/26/2006 19:10:00 9.2 1.1 11.5 6.8 8.5 1.2 11.5 5.7 285 8 288 305 -17.8 0 -17.5 -18.1 02/26/2006 19:20:00 9.6 1.2 12.6 6.1 8.8 1.2 12.2 6.1 284 7 287 305 -17.8 0 -17.7 -18.1 02/26/2006 19:30:00 9.3 1.3 12.2 6.5 8.9 1.3 12.2 6.1 293 7 292 305 -18 0 -17.9 -18.1 02/26/2006 19:40:00 8.1 1 10.7 6.1 7.7 1 10.3 5.3 292 6 291 305 -18 0 -17.7 -18.1 02/26/2006 19:50:00 8.5 1.1 11.1 5.7 8 1.2 11.1 4.9 291 11 287 305 -18 0 -17.5 -18.1 02/26/2006 20:00:00 8.4 1 10.3 5.7 7.5 1.2 10.7 4.2 282 6 278 305 -18 0.1 -17.5 -18.2 02/26/2006 20:10:00 8 1 10.3 4.6 6.9 1.2 9.5 3.4 277 7 280 305 -18.1 0.1 -17.5 -18.2 02/26/2006 20:20:00 7.4 0.8 9.5 5.3 6.4 1 9.1 3.4 277 7 273 305 -18.1 0.1 -17.5 -18.2 02/26/2006 20:30:00 7.3 0.9 9.9 4.9 6.8 1 9.5 4.2 290 9 294 305 -18 0.1 -17.5 -18.1 02/26/2006 20:40:00 8 0.9 10.3 5.7 7.2 1 9.9 4.9 284 5 284 305 -18 0.1 -17.5 -18.2 02/26/2006 20:50:00 7.8 0.8 9.5 5.3 7 1 9.5 4.6 283 11 280 305 -18.1 0.1 -17.5 -18.2 02/26/2006 21:00:00 7 0.9 9.1 4.6 5.8 1.1 8 3 274 7 285 305 -18.1 0.1 -17.5 -18.4 02/26/2006 21:10:00 6.8 0.9 8.8 4.6 5.6 1.1 8 2.6 273 7 264 305 -18.3 0 -18.1 -18.4 02/26/2006 21:20:00 6.4 1 8.8 4.2 5.1 1 8 3 270 8 284 305 -18.4 0 -18.2 -18.4 02/26/2006 21:30:00 6.2 1 8.4 3.8 4.8 1.1 7.6 2.6 270 8 263 305 -18.5 0 -18.4 -18.4 02/26/2006 21:40:00 6.8 0.8 8.4 4.2 5.4 0.8 7.2 3.4 267 6 268 305 -18.5 0 -18.1 -18.4 02/26/2006 21:50:00 5.9 0.8 8 3.8 4.5 0.8 6.8 2.6 266 7 262 305 -18.5 0 -18.1 -18.4 02/26/2006 22:00:00 4.4 0.5 5.7 3 3.3 0.6 4.9 1.5 263 6 263 305 -18.6 0 -18.1 -18.8 02/26/2006 22:10:00 3.5 0.6 4.9 1.9 2.3 0.6 3.8 1.1 273 9 275 305 -18.7 0 -18.4 -19 02/26/2006 22:20:00 3.3 0.5 4.2 2.3 2.3 0.5 3.8 1.1 274 8 276 305 -18.7 0.1 -18.1 -19 02/26/2006 22:30:00 2.1 0.5 3.8 1.1 1.7 0.5 3 0.4 318 30 284 305 -18.6 0.2 -18.1 -19 02/26/2006 22:40:00 5.1 1.7 7.2 0.4 4.9 1.7 7.2 0.4 27 26 27 305 -18.3 0.3 -17.9 -19 02/26/2006 22:50:00 5.8 0.5 7.2 4.6 5.7 0.5 6.8 4.6 27 5 22 305 -18 0 -17.5 -18.1 02/26/2006 23:00:00 6.1 0.6 7.6 4.6 5.8 0.6 7.6 4.6 24 5 27 305 -18.1 0 -17.5 -18.2 02/26/2006 23:10:00 6.6 0.4 7.6 5.7 6.4 0.4 7.6 4.9 24 3 25 305 -18.3 0.1 -18.1 -18.4 02/26/2006 23:20:00 6.6 0.5 8 5.3 6.4 0.5 8 4.9 24 4 21 305 -18.5 0 -18.1 -18.8 02/26/2006 23:30:00 6.6 0.5 7.6 4.9 6.4 0.6 8 4.9 27 4 29 305 -18.9 0.1 -18.4 -19 02/26/2006 23:40:00 6.6 0.5 7.6 5.3 6.5 0.5 8.4 5.3 23 4 25 305 -19 0 -18.4 -19 02/26/2006 23:50:00 7.6 1 9.5 5.3 7.5 1.1 9.5 5.3 12 10 4 305 -19.1 0 -18.8 -19.2 02/27/2006 00:00:00 7.3 0.9 9.9 5.7 7.2 1 9.9 4.9 4 5 4 305 -19.2 0.1 -18.6 -19.5 02/27/2006 00:10:00 8.7 0.8 10.3 6.5 8.9 0.8 10.7 6.1 4 4 7 305 -19.4 0.2 -19 -19.5 02/27/2006 00:20:00 8 0.9 9.9 5.3 8 1 10.3 6.1 12 8 16 305 -19.6 0.1 -19 -19.9 02/27/2006 00:30:00 7.1 0.9 9.1 4.6 7 1 9.5 4.2 17 5 11 305 -19.7 0.1 -19.2 -19.9 02/27/2006 00:40:00 7.5 0.9 9.1 4.9 7.5 1 9.1 4.9 14 5 22 305 -19.6 0.1 -19 -19.7 02/27/2006 00:50:00 7.6 1.2 9.9 4.9 7.6 1.2 9.9 4.9 15 5 15 305 -19.5 0.1 -19 -19.5 02/27/2006 01:00:00 8 1 9.9 5.3 7.9 1 11.1 5.3 16 5 16 305 -19.5 0.1 -19 -19.5 02/27/2006 01:10:00 8.4 0.9 9.9 5.7 8.3 0.9 10.3 6.1 17 5 21 305 -19.5 0.1 -19 -19.7 02/27/2006 01:20:00 8.3 1 10.7 5.3 8.4 1 10.3 5.7 15 5 14 305 -19.7 0.2 -19 -19.9 02/27/2006 01:30:00 8.6 0.8 10.7 6.5 8.6 0.8 10.7 6.1 14 5 18 305 -19.7 0.1 -19.2 -19.9 02/27/2006 01:40:00 8.9 0.8 10.7 6.8 8.7 0.8 10.7 6.8 13 5 12 305 -19.7 0.1 -19.2 -19.9 02/27/2006 01:50:00 8.8 1 10.7 6.8 8.7 0.9 11.1 5.7 11 5 2 305 -19.7 0.1 -19.2 -19.9 02/27/2006 02:00:00 8.4 1 10.3 5.7 8.3 1.1 10.3 5.3 14 5 16 305 -19.7 0.1 -19.2 -19.9 02/27/2006 02:10:00 8.8 1 11.5 6.1 8.5 1 10.7 6.1 13 5 20 305 -19.7 0.1 -19.2 -19.9 02/27/2006 02:20:00 9 1.1 11.5 6.5 8.8 1.1 11.5 6.5 12 5 9 305 -19.8 0.2 -19.2 -20.1 02/27/2006 02:30:00 9.2 1.1 11.5 6.5 9 1.1 11.5 6.5 12 5 11 305 -20.2 0 -19.5 -20.1 02/27/2006 02:40:00 10 0.9 12.2 6.5 9.8 1 11.8 6.5 12 4 6 305 -20.1 0.1 -19.5 -20.1 02/27/2006 02:50:00 9.9 1 11.8 8 9.7 0.9 12.2 7.6 10 5 7 305 -20 0.1 -19.5 -20.1 02/27/2006 03:00:00 10.3 1 12.6 7.6 10.2 1 12.6 7.2 8 5 8 305 -19.8 0.1 -19.2 -20.1 02/27/2006 03:10:00 10.1 0.9 12.2 7.6 10 1 13 8 8 5 11 305 -19.7 0.1 -19.2 -19.9 02/27/2006 03:20:00 11 1.1 13.3 8.4 10.9 1.2 14.1 8 4 4 3 305 -19.7 0.2 -19.2 -20.1 02/27/2006 03:30:00 11.5 1.4 14.9 7.6 11.4 1.4 15.3 8 5 5 5 305 -19.9 0.1 -19.3 -20.1 02/27/2006 03:40:00 12.2 1.4 15.6 8.4 12.1 1.5 15.6 8.4 7 4 9 305 -20 0.2 -19.5 -20.1 02/27/2006 03:50:00 12 1.5 15.3 8 11.8 1.5 15.3 8 9 5 8 305 -20.1 0.1 -19.5 -20.1 02/27/2006 04:00:00 12.4 1.2 15.6 9.1 12.4 1.3 15.3 9.1 11 4 7 305 -20.1 0.1 -19.5 -20.1 02/27/2006 04:10:00 11.3 1.2 14.5 8.4 11.1 1.1 14.1 8 12 5 14 305 -19.9 0.1 -19.3 -20.1 02/27/2006 04:20:00 12.5 1.2 14.9 9.5 12.3 1.2 14.5 9.1 14 5 19 305 -20 0.1 -19.5 -20.1 02/27/2006 04:30:00 11.6 1.2 14.1 8.8 11.5 1.2 14.9 8.8 10 6 2 305 -19.9 0.1 -19.5 -20.1 02/27/2006 04:40:00 13.1 1 15.3 10.3 12.8 1.1 16.1 10.3 8 5 3 305 -19.9 0.1 -19.5 -20.1 02/27/2006 04:50:00 11 1.3 13.7 7.6 10.9 1.3 14.1 7.6 10 5 12 305 -20 0.1 -19.5 -20.1 02/27/2006 05:00:00 11 1.2 13.3 8.4 11 1.1 13.3 8.4 8 5 10 305 -20 0.1 -19.5 -20.1 02/27/2006 05:10:00 12 0.9 14.1 8.8 11.8 0.9 13.7 9.1 7 4 9 305 -19.9 0.1 -19.3 -20.1 02/27/2006 05:20:00 12.1 1.1 14.1 9.1 12 1.1 14.1 8.8 6 4 4 305 -19.8 0.1 -19.3 -20.1 02/27/2006 05:30:00 12.1 1.1 14.5 9.1 12 1.1 14.9 8.8 4 5 5 305 -19.9 0.1 -19.3 -20.1 02/27/2006 05:40:00 10.6 1.6 13.7 6.5 10.5 1.7 13.7 6.5 4 6 8 305 -20.1 0.1 -19.5 -20.1 02/27/2006 05:50:00 10.2 1.1 13 6.8 10.1 1.1 13.3 6.8 5 6 1 305 -20.1 0.1 -19.5 -20.1 02/27/2006 06:00:00 10.2 1.6 14.9 7.2 10.2 1.5 14.9 7.2 358 6 1 305 -19.8 0.2 -19.2 -20.1 02/27/2006 06:10:00 11.8 1.2 14.5 8.8 11.8 1.2 14.9 8.4 4 5 4 305 -19.8 0.1 -19.3 -20.1 02/27/2006 06:20:00 11.1 1 13.3 8.8 11.1 1 13.3 8 9 5 12 305 -20 0.2 -19.5 -20.1 02/27/2006 06:30:00 10.9 0.9 13 8.4 10.9 0.9 13.3 8.8 7 4 11 305 -19.9 0.1 -19.3 -20.1 02/27/2006 06:40:00 9.5 1.1 12.2 6.8 9.5 1.2 12.2 7.2 5 5 7 305 -19.7 0.1 -19.2 -20.1 02/27/2006 06:50:00 10 1 12.6 7.2 10 1.1 13 6.8 357 6 353 305 -19.5 0.2 -19 -19.7 02/27/2006 07:00:00 10.1 0.9 12.2 8 10.2 0.8 12.2 7.6 355 4 355 305 -19.4 0.2 -18.8 -19.5 02/27/2006 07:10:00 9.2 1.6 12.6 5.7 9.1 1.6 13 6.1 0 7 358 305 -19.6 0.1 -19 -19.9 02/27/2006 07:20:00 9.8 1.3 12.6 6.5 9.8 1.3 13 6.8 0 5 5 305 -19.8 0.1 -19.2 -20.1 02/27/2006 07:30:00 8.9 1.4 11.8 4.9 8.8 1.3 11.8 4.9 357 7 3 305 -19.7 0.2 -19 -20.1 02/27/2006 07:40:00 8.4 1.5 11.5 4.6 8.2 1.6 12.2 4.6 347 9 344 305 -19.7 0.2 -19 -19.9 02/27/2006 07:50:00 8.7 1.3 12.6 5.7 8.5 1.5 12.6 4.9 349 11 4 305 -19.7 0.2 -19.2 -19.9 02/27/2006 08:00:00 8.7 1.1 11.8 6.5 8.6 1.2 11.5 6.1 352 6 6 305 -19.7 0.1 -19.2 -19.9 02/27/2006 08:10:00 9.9 1.1 12.6 6.5 10 1.1 13 7.2 355 7 4 305 -19.8 0.1 -19.2 -20.1 02/27/2006 08:20:00 7.1 1.2 10.7 4.2 6.9 1.2 10.3 4.6 351 11 348 305 -19.8 0.2 -19.3 -20.1 02/27/2006 08:30:00 7.5 0.9 10.3 5.7 7.4 1 9.5 4.9 357 7 359 305 -19.9 0.2 -19.3 -20.1 02/27/2006 08:40:00 9.5 0.8 11.1 7.2 9.5 0.8 11.1 7.2 3 7 2 305 -19.8 0.2 -19.2 -20.1 02/27/2006 08:50:00 8.1 0.9 10.3 6.1 8 0.9 9.9 6.1 5 6 16 305 -20 0.2 -19.5 -20.1 02/27/2006 09:00:00 9.6 1.1 12.6 6.8 9.6 1.1 12.2 6.8 5 5 4 305 -19.6 0.2 -19 -20.1 02/27/2006 09:10:00 9.5 1.3 13 6.1 9.3 1.3 12.6 6.8 7 6 8 305 -19.7 0.1 -19 -19.9 02/27/2006 09:20:00 7.7 1 10.3 5.3 7.7 1 10.3 5.3 13 5 21 305 -19.8 0.2 -19.2 -20.1 02/27/2006 09:30:00 7.1 0.8 9.5 4.9 6.9 0.7 9.5 5.3 17 6 17 305 -20.1 0.2 -19.5 -20.1 02/27/2006 09:40:00 8.3 1.2 11.5 5.3 8.2 1.2 11.5 5.3 8 6 7 305 -19.7 0.2 -19 -20.1 02/27/2006 09:50:00 9.4 1.1 11.8 6.1 9.2 1.1 11.8 6.5 14 5 12 305 -19.6 0.1 -19 -19.9 02/27/2006 10:00:00 9.2 1 11.1 6.5 9 1 11.8 6.5 13 5 14 305 -19.6 0.1 -19 -19.9 02/27/2006 10:10:00 9.9 1.3 13 6.8 9.8 1.3 12.6 6.8 10 5 11 305 -19.7 0.2 -19 -20.1 02/27/2006 10:20:00 10.2 1.1 12.6 7.2 10.1 1.1 13 7.2 12 5 13 305 -20 0.2 -19.5 -20.1 02/27/2006 10:30:00 8.9 0.8 11.1 7.2 8.7 0.8 10.7 6.8 18 6 9 305 -20.1 0.1 -19.5 -20.2 02/27/2006 10:40:00 10.8 1.5 14.1 7.6 10.8 1.5 14.5 8 21 4 23 305 -20.1 0.1 -19.5 -20.2 02/27/2006 10:50:00 12 0.8 14.1 9.9 11.8 0.9 14.1 8.8 20 4 26 305 -20 0.1 -19.5 -20.1 02/27/2006 11:00:00 10.2 0.9 12.2 8 10 1.1 12.2 7.2 15 5 14 305 -19.7 0.1 -19.2 -20.1 02/27/2006 11:10:00 8.9 0.7 10.7 7.2 8.7 0.7 10.3 6.8 20 5 20 305 -19.7 0 -19.3 -19.9 02/27/2006 11:20:00 8.4 0.8 10.3 6.1 8.3 0.8 10.3 6.5 22 4 15 305 -19.7 0 -19.5 -19.7 02/27/2006 11:30:00 8.1 0.6 9.5 5.7 7.9 0.7 9.5 5.7 19 4 19 305 -19.6 0 -19 -19.7 02/27/2006 11:40:00 7.8 0.7 9.5 5.7 7.6 0.7 9.9 5.7 21 5 18 305 -19.3 0.1 -19 -19.5 02/27/2006 11:50:00 7.2 1 9.1 4.9 7.1 1 9.1 4.6 22 5 19 305 -19.2 0 -18.8 -19.3 02/27/2006 12:00:00 7 0.6 8.4 5.3 6.8 0.6 8.4 4.9 25 5 29 305 -19.2 0 -18.4 -19.3 02/27/2006 12:10:00 5.7 0.7 7.2 3.8 5.6 0.7 7.2 4.2 25 5 21 305 -19.1 0 -19 -19.2 02/27/2006 12:20:00 7.1 1.4 9.5 3.8 7.1 1.4 9.5 4.2 17 7 11 305 -18.8 0 -18.4 -19 02/27/2006 12:30:00 6.4 1 9.1 4.2 6.3 1 8.8 4.2 21 8 12 305 -18.8 0.1 -18.4 -19 02/27/2006 12:40:00 6.4 0.6 8.4 4.6 6.4 0.7 8.4 4.9 22 11 3 305 -19 0 -18.6 -19 02/27/2006 12:50:00 6.7 0.7 8.4 4.9 6.8 0.7 8.4 4.6 6 6 10 305 -18.7 0 -18.4 -19 02/27/2006 13:00:00 6.6 0.7 8 4.6 6.7 0.7 8 4.9 1 4 7 305 -18.6 0 -18.4 -18.8 02/27/2006 13:10:00 6.1 0.6 7.6 4.6 6.1 0.7 8 3.8 3 5 358 305 -18.5 0 -18.2 -18.6 02/27/2006 13:20:00 5.6 0.7 7.2 3.8 5.6 0.7 7.2 3.8 2 6 357 305 -18.7 0 -18.4 -19 02/27/2006 13:30:00 5.4 0.5 6.8 4.2 5.4 0.6 6.8 4.2 5 5 8 305 -18.6 0 -18.4 -18.8 02/27/2006 13:40:00 5.5 0.6 6.5 4.2 5.5 0.6 6.8 4.2 4 5 4 305 -18.7 0 -18.4 -18.8 02/27/2006 13:50:00 4.8 0.5 6.1 3.4 4.8 0.5 6.1 3 6 5 12 305 -18.4 0.1 -18.2 -18.6 02/27/2006 14:00:00 5.1 0.5 6.1 3.8 5.1 0.6 6.5 3.8 4 4 4 305 -18.4 0.1 -18.1 -18.6 02/27/2006 14:10:00 4.5 0.4 5.7 3.4 4.5 0.4 5.7 3.4 359 5 352 305 -18.2 0.1 -18.1 -18.4 02/27/2006 14:20:00 3.5 0.5 4.6 2.3 3.6 0.4 4.6 2.6 13 5 10 305 -18 0 -17.9 -18.1 02/27/2006 14:30:00 3.9 0.5 4.9 2.3 4 0.5 5.3 2.3 13 4 12 305 -18.1 0 -17.9 -18.4 02/27/2006 14:40:00 4.2 0.5 5.3 2.6 4.1 0.5 5.3 3 14 3 14 305 -18.1 0 -17.9 -18.4 02/27/2006 14:50:00 4.6 0.5 5.7 3.4 4.6 0.5 5.7 3.4 19 5 20 305 -18.1 0 -18.1 -18.4 02/27/2006 15:00:00 4.8 0.6 5.7 3.4 4.7 0.5 5.7 3.4 25 7 21 305 -18.1 0 -17.9 -18.2 02/27/2006 15:10:00 4.1 0.6 5.7 3 4.2 0.6 5.7 3 30 8 30 305 -17.9 0 -17.7 -18.1 02/27/2006 15:20:00 4.3 0.8 5.7 2.3 4.3 0.9 5.7 2.3 39 5 37 305 -18 0.2 -17.5 -18.4 02/27/2006 15:30:00 4.8 0.4 5.7 3.8 4.8 0.4 5.7 3.8 48 4 47 305 -18.3 0 -18.1 -18.4 02/27/2006 15:40:00 5 0.5 6.1 3.8 5 0.5 6.1 3.8 40 4 38 305 -18.2 0 -18.1 -18.4 02/27/2006 15:50:00 5.3 0.4 6.1 4.2 5.3 0.4 6.1 4.2 34 4 32 305 -18.2 0 -18.1 -18.4 02/27/2006 16:00:00 5.2 0.5 6.5 4.2 5.1 0.5 6.5 4.2 44 7 51 305 -18.2 0.1 -18.1 -18.4 02/27/2006 16:10:00 4.8 0.5 5.7 3.4 4.7 0.5 5.7 3.4 45 6 53 305 -18.4 0 -18.2 -18.4 02/27/2006 16:20:00 4.4 0.5 5.7 3.4 4.4 0.5 5.7 3 34 8 49 305 -18.3 0.1 -18.1 -18.4 02/27/2006 16:30:00 4.1 0.3 5.3 3.4 4.1 0.3 4.9 3.4 22 5 23 305 -18 0 -17.7 -18.2 02/27/2006 16:40:00 3.6 0.4 4.6 2.3 3.6 0.4 4.6 2.6 17 6 13 305 -17.7 0 -17.5 -18.1 02/27/2006 16:50:00 3.7 0.5 4.6 2.6 3.7 0.5 4.6 2.6 19 6 30 305 -17.5 0 -17.3 -17.7 02/27/2006 17:00:00 2.7 0.4 3.4 1.5 2.8 0.4 3.8 1.9 359 11 11 305 -17.4 0 -17.1 -17.5 02/27/2006 17:10:00 4.1 1.5 7.2 2.3 4.1 1.4 7.2 2.3 4 14 20 305 -17.6 0.2 -17.3 -18.1 02/27/2006 17:20:00 5.5 0.8 8 4.2 5.7 0.8 8.4 4.2 4 7 2 305 -18 0 -17.9 -18.1 02/27/2006 17:30:00 5.9 0.8 8 3.8 6 0.9 8.4 3.8 4 6 10 305 -18 0 -17.7 -18.2 02/27/2006 17:40:00 6.6 0.8 8.4 4.2 6.7 0.8 8.4 4.6 5 7 4 305 -18.2 0.1 -17.5 -18.4 02/27/2006 17:50:00 5.7 0.8 7.6 3.4 5.7 0.8 7.6 3.8 5 6 0 305 -18.6 0 -18.1 -18.8 02/27/2006 18:00:00 5.3 0.7 7.2 3.8 5.3 0.7 7.6 4.2 359 6 1 305 -18.7 0 -18.4 -19 02/27/2006 18:10:00 5.6 0.9 7.6 3.4 5.6 1 7.6 3 6 6 10 305 -18.6 0 -18.4 -18.8 02/27/2006 18:20:00 6.3 0.6 8 4.6 6.3 0.6 7.6 4.6 11 5 10 305 -18.6 0 -18.4 -18.6 02/27/2006 18:30:00 5.9 0.6 7.2 4.2 5.9 0.6 7.2 4.6 12 7 13 305 -18.6 0 -18.4 -18.8 02/27/2006 18:40:00 6.7 0.9 8.8 4.9 6.6 1 8.8 4.6 11 4 13 305 -18.7 0 -18.4 -19 02/27/2006 18:50:00 5.5 0.8 7.2 3.4 5.4 0.8 7.2 3.4 12 6 12 305 -18.9 0 -18.4 -19 02/27/2006 19:00:00 5.8 0.9 7.6 3.8 5.8 1 8 3.8 27 10 17 305 -18.8 0.1 -18.1 -19 02/27/2006 19:10:00 4.8 0.4 5.7 3.8 4.8 0.5 6.1 3.4 30 5 28 305 -19.1 0 -18.4 -19.2 02/27/2006 19:20:00 4.9 0.6 6.5 3.4 4.8 0.6 6.5 3.4 29 4 28 305 -19.2 0 -18.8 -19.3 02/27/2006 19:30:00 5.2 0.5 6.5 3.8 5.1 0.5 6.5 3.8 26 5 31 305 -19.2 0 -18.6 -19.3 02/27/2006 19:40:00 5.6 0.6 7.2 4.2 5.5 0.7 7.2 3.8 33 6 28 305 -19.2 0 -19 -19.3 02/27/2006 19:50:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 3.8 30 5 25 305 -19.2 0 -18.8 -19.5 02/27/2006 20:00:00 5.1 0.5 6.5 3.8 5 0.5 6.5 3.8 37 6 31 305 -19.3 0.1 -18.8 -19.5 02/27/2006 20:10:00 5.2 0.4 6.5 4.2 5 0.4 6.1 4.2 42 3 36 305 -19.4 0.1 -19 -19.5 02/27/2006 20:20:00 5.5 0.4 6.5 4.2 5.4 0.4 6.1 4.2 49 6 39 305 -19.5 0.1 -18.8 -19.7 02/27/2006 20:30:00 5.1 0.3 5.7 4.2 4.9 0.3 5.7 4.2 46 3 53 305 -19.6 0.1 -19 -19.9 02/27/2006 20:40:00 5.3 0.4 6.1 4.2 5 0.4 6.1 4.2 50 5 44 305 -19.6 0.1 -19.2 -19.9 02/27/2006 20:50:00 5 0.4 6.1 3.8 4.6 0.4 5.7 3.4 59 7 60 305 -19.7 0.1 -19.2 -19.9 02/27/2006 21:00:00 4.6 0.6 6.1 3.4 4.5 0.6 5.7 3.4 70 7 78 305 -19.7 0.2 -19 -20.1 02/27/2006 21:10:00 3.8 0.4 4.6 2.6 3.6 0.4 4.6 2.6 60 5 70 305 -19.4 0.1 -18.8 -19.5 02/27/2006 21:20:00 3.9 0.3 4.6 3 3.7 0.3 4.6 3 57 4 58 305 -19.3 0.1 -18.8 -19.5 02/27/2006 21:30:00 4.6 0.7 6.1 2.6 4.4 0.8 6.1 2.3 73 9 75 305 -19.3 0.2 -18.4 -19.5 02/27/2006 21:40:00 5.3 0.5 6.5 4.2 5.1 0.4 6.1 3.8 76 7 71 305 -19.2 0.2 -18.4 -19.5 02/27/2006 21:50:00 5.7 0.5 7.2 3.8 5.6 0.5 6.5 3.8 89 9 77 305 -19.6 0.2 -19 -19.9 02/27/2006 22:00:00 5.6 0.4 6.8 3.4 5.4 0.4 6.5 3.8 89 5 90 305 -19.9 0.2 -19.2 -20.2 02/27/2006 22:10:00 5.1 0.5 6.5 4.2 4.7 0.5 5.7 3.8 83 5 76 305 -19.9 0.2 -19.3 -20.1 02/27/2006 22:20:00 4.3 0.4 5.3 3 4 0.4 4.9 3 83 6 78 305 -19.6 0.1 -19.2 -19.9 02/27/2006 22:30:00 5.1 0.4 6.1 3.8 4.8 0.5 5.7 3.4 89 9 76 305 -19.9 0.2 -19.2 -20.1 02/27/2006 22:40:00 5.2 0.7 6.8 3.4 4.9 0.8 6.5 3 75 4 74 305 -19.7 0.2 -19 -20.1 02/27/2006 22:50:00 3.6 0.7 4.9 1.9 3.2 0.8 4.6 1.9 76 8 67 305 -19.7 0.1 -19 -19.9 02/27/2006 23:00:00 2.7 0.5 3.8 0.7 2.2 0.5 3.4 0.7 82 15 86 305 -19.7 0.2 -19.2 -20.1 02/27/2006 23:10:00 1.1 0.8 3.4 0.4 1 0.7 3 0.4 188 72 203 305 -19.6 0.1 -19 -19.9 02/27/2006 23:20:00 1.8 0.7 3.4 0.4 1.7 0.8 3.4 0.4 220 32 234 305 -19.9 0.1 -19.3 -20.2 02/27/2006 23:30:00 3.1 0.6 4.6 1.1 3.1 0.6 4.6 1.1 199 6 198 305 -21 0.3 -19.9 -21.5 02/27/2006 23:40:00 4.7 0.6 5.7 3 4.8 0.6 5.7 3.4 199 4 197 305 -21.7 0.2 -21.1 -22.2 02/27/2006 23:50:00 4.4 0.3 4.9 3.4 4.5 0.3 4.9 3.8 198 3 196 305 -21.7 0.1 -21.3 -22 02/28/2006 00:00:00 4.4 0.3 4.9 3.8 4.4 0.3 4.9 3.8 195 3 200 305 -21.4 0.2 -20.8 -21.8 02/28/2006 00:10:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.8 196 3 196 305 -21.2 0.2 -20.8 -21.5 02/28/2006 00:20:00 3.8 0.5 4.9 2.3 3.9 0.3 4.9 3.4 190 5 196 305 -21 0.2 -20.4 -21.3 02/28/2006 00:30:00 3.7 0.3 4.6 2.6 3.8 0.3 4.6 3 190 4 192 305 -20.6 0.2 -20.1 -21 02/28/2006 00:40:00 3.9 0.3 4.6 3 3.9 0.3 4.9 3 194 3 196 305 -20.6 0.2 -20.1 -20.8 02/28/2006 00:50:00 4 0.3 4.6 3 3.9 0.3 4.6 3.4 196 4 195 305 -20.5 0.2 -20.1 -20.8 02/28/2006 01:00:00 3.7 0.2 4.2 3 3.6 0.2 4.2 3 197 4 201 305 -20.4 0.2 -19.9 -20.8 02/28/2006 01:10:00 3.3 0.2 4.2 2.6 3.3 0.2 3.8 2.6 196 3 200 305 -20.2 0.2 -19.7 -20.4 02/28/2006 01:20:00 2.7 0.5 4.2 1.1 2.7 0.5 4.6 1.5 185 10 193 305 -20.3 0.2 -19.9 -20.8 02/28/2006 01:30:00 4.5 0.5 5.3 2.3 4.5 0.5 5.7 3 190 5 196 305 -20.4 0.3 -19.5 -20.8 02/28/2006 01:40:00 4.3 0.3 4.9 3.8 4.3 0.2 4.9 3.8 192 3 190 305 -20.1 0.2 -19.5 -20.2 02/28/2006 01:50:00 4.8 0.4 6.1 3.8 4.8 0.4 6.1 3.8 202 4 205 305 -20.5 0.2 -19.9 -21 02/28/2006 02:00:00 5.3 0.4 6.1 4.2 5.1 0.4 6.1 3.8 202 4 209 305 -20.4 0.2 -19.7 -20.8 02/28/2006 02:10:00 5.2 0.3 6.1 4.6 5.1 0.3 6.5 4.6 199 4 194 305 -20.2 0.2 -19.5 -20.6 02/28/2006 02:20:00 4.9 0.3 6.1 4.2 4.8 0.3 5.7 4.2 200 5 201 305 -19.7 0.2 -19 -20.1 02/28/2006 02:30:00 4.9 0.4 5.7 4.2 4.8 0.5 5.7 3.4 199 4 197 305 -19.4 0.1 -19 -19.5 02/28/2006 02:40:00 5.1 0.3 5.7 4.2 5.2 0.3 5.7 4.2 191 3 198 305 -19.7 0.2 -19 -20.1 02/28/2006 02:50:00 4.8 0.4 5.7 3.4 5 0.4 5.7 4.2 187 4 187 305 -19.7 0.2 -19.2 -20.1 02/28/2006 03:00:00 5.1 0.3 6.1 4.2 5.2 0.4 6.5 4.2 188 3 188 305 -19.4 0.2 -19 -19.5 02/28/2006 03:10:00 5.7 0.3 6.5 4.9 5.8 0.3 6.5 4.9 193 3 194 305 -19.4 0.2 -18.8 -19.5 02/28/2006 03:20:00 6.2 0.2 6.8 5.7 6.3 0.4 7.2 5.3 191 2 192 305 -19.5 0.1 -19 -19.9 02/28/2006 03:30:00 6.4 0.3 7.2 5.7 6.6 0.3 7.2 5.7 190 2 193 305 -19.9 0.1 -19.5 -20.1 02/28/2006 03:40:00 6 0.4 7.2 4.9 6.2 0.3 6.8 5.3 192 3 193 305 -20.1 0.1 -19.3 -20.2 02/28/2006 03:50:00 5.7 0.3 6.5 4.9 6.1 0.3 6.8 5.3 190 3 188 305 -19.9 0.1 -19.3 -20.1 02/28/2006 04:00:00 5.4 0.3 6.5 4.6 5.5 0.3 6.5 4.6 192 4 196 305 -19.7 0.2 -19 -20.1 02/28/2006 04:10:00 5.4 0.4 6.5 3.8 5.5 0.4 6.5 4.2 195 6 192 305 -19.5 0.1 -19 -19.7 02/28/2006 04:20:00 5.3 0.4 6.5 4.2 5.3 0.4 6.1 3.8 198 5 192 305 -19.4 0.1 -19 -19.5 02/28/2006 04:30:00 5.3 0.4 6.5 4.2 5.4 0.4 6.5 3.8 200 5 200 305 -19.5 0 -19.2 -19.5 02/28/2006 04:40:00 5.2 0.4 6.5 4.2 5.4 0.5 6.5 4.2 196 6 198 305 -19.5 0 -19 -19.5 02/28/2006 04:50:00 5.6 0.3 6.5 4.9 5.8 0.3 6.8 4.9 196 4 196 305 -19.5 0 -19 -19.5 02/28/2006 05:00:00 5.8 0.4 6.8 4.9 5.9 0.4 7.2 4.6 197 5 195 305 -19.5 0.1 -19 -19.5 02/28/2006 05:10:00 6.1 0.5 7.6 4.6 6.3 0.6 8 4.9 193 5 194 305 -19.7 0.1 -19 -19.9 02/28/2006 05:20:00 6.4 0.4 8 4.9 6.6 0.4 7.6 5.3 193 4 194 305 -19.7 0.1 -19.2 -19.9 02/28/2006 05:30:00 6.2 0.3 7.2 5.3 6.5 0.3 7.2 5.7 195 4 194 305 -19.6 0 -19 -19.9 02/28/2006 05:40:00 6 0.3 6.8 5.3 6.2 0.3 7.2 5.3 194 2 190 305 -19.7 0 -19.2 -19.9 02/28/2006 05:50:00 5.9 0.2 6.5 5.3 6.2 0.3 6.8 5.7 195 2 192 305 -19.6 0.1 -19 -19.9 02/28/2006 06:00:00 6.1 0.3 6.8 4.9 6.2 0.3 6.8 5.3 191 2 192 305 -19.6 0.1 -19 -19.7 02/28/2006 06:10:00 5.4 0.4 6.1 3.8 5.7 0.4 6.5 4.9 188 4 193 305 -19.7 0.1 -19.2 -19.9 02/28/2006 06:20:00 4.5 0.6 5.7 3 5.1 0.3 5.7 4.2 183 4 186 305 -19.6 0.1 -19 -19.9 02/28/2006 06:30:00 4.9 0.4 5.7 3.4 5.2 0.3 5.7 4.6 186 3 190 305 -19.6 0 -19 -19.7 02/28/2006 06:40:00 4.9 0.4 5.7 3.4 5 0.3 5.7 4.2 187 3 186 305 -19.6 0 -19 -19.7 02/28/2006 06:50:00 5.4 0.4 6.1 4.2 5.4 0.4 6.5 4.2 193 3 196 305 -19.5 0.1 -19 -19.5 02/28/2006 07:00:00 5.6 0.3 6.5 4.9 5.6 0.3 6.1 4.6 196 3 199 305 -19.5 0.1 -19 -19.5 02/28/2006 07:10:00 5.2 0.4 6.1 4.2 5.2 0.4 6.1 4.6 197 3 198 305 -19.4 0.1 -19 -19.5 02/28/2006 07:20:00 4.7 0.3 5.3 3.8 4.8 0.3 5.7 4.2 193 3 198 305 -19.5 0.1 -19 -19.7 02/28/2006 07:30:00 4.1 0.3 4.6 3.4 4.1 0.3 4.9 3 188 3 194 305 -19.3 0.1 -18.8 -19.5 02/28/2006 07:40:00 3.2 0.6 4.2 1.1 3.6 0.6 4.6 1.5 180 9 183 305 -19.3 0.1 -18.8 -19.5 02/28/2006 07:50:00 3.4 0.8 4.6 1.1 3.6 0.7 4.6 1.5 182 8 182 305 -19.5 0.2 -19 -19.9 02/28/2006 08:00:00 4.1 0.6 4.9 1.9 4.3 0.4 4.9 3 187 5 190 305 -19.2 0.1 -18.4 -19.5 02/28/2006 08:10:00 2.9 0.9 5.3 1.1 3.8 0.9 5.7 2.3 167 9 163 305 -19.5 0.2 -18.4 -19.9 02/28/2006 08:20:00 4.2 0.9 6.1 1.9 5.1 0.5 6.5 3.4 159 7 151 305 -20.1 0.2 -19.2 -20.6 02/28/2006 08:30:00 4.3 0.7 6.1 2.3 4.9 0.5 6.1 3.8 156 7 156 305 -20.3 0 -20.1 -20.6 02/28/2006 08:40:00 3.4 0.7 5.3 1.9 4.4 0.5 5.7 3 163 6 156 305 -19.9 0.1 -19.5 -20.2 02/28/2006 08:50:00 3.9 1.3 6.1 1.9 4.7 0.8 6.1 2.6 158 9 151 305 -20.1 0.2 -19.7 -20.6 02/28/2006 09:00:00 6.3 0.7 7.6 4.6 6.4 1 8 3.8 132 4 130 305 -20.6 0.1 -20.1 -20.8 02/28/2006 09:10:00 8.2 0.6 9.5 6.8 8.5 0.5 9.5 7.2 138 5 141 305 -20.5 0.1 -20.1 -20.8 02/28/2006 09:20:00 8.4 0.6 10.3 6.8 8.2 0.6 9.9 6.8 149 4 154 305 -20.5 0.1 -20.1 -20.8 02/28/2006 09:30:00 8.8 0.8 10.7 6.5 8.6 0.8 10.7 6.5 153 4 157 305 -20.6 0.1 -19.7 -20.8 02/28/2006 09:40:00 9.5 0.8 11.1 7.2 9.4 0.6 10.7 7.6 152 4 153 305 -19.8 0.1 -19.2 -20.1 02/28/2006 09:50:00 9.1 0.6 10.7 7.2 9.2 0.7 10.7 7.2 149 4 143 305 -20 0.1 -19.3 -20.1 02/28/2006 10:00:00 9.3 0.5 10.7 7.6 9.3 0.5 10.7 7.6 149 3 148 305 -20.3 0.1 -19.7 -20.6 02/28/2006 10:10:00 9.2 0.9 11.1 6.8 9 0.7 10.7 7.2 154 5 156 305 -20.2 0.1 -19.9 -20.4 02/28/2006 10:20:00 9.1 0.6 10.7 7.6 8.9 0.6 10.3 7.2 149 4 152 305 -20.6 0 -20.1 -20.8 02/28/2006 10:30:00 9.3 0.4 10.7 8 9 0.5 10.3 7.6 147 3 155 305 -20.7 0 -20.1 -21 02/28/2006 10:40:00 9.7 0.5 11.1 8.4 9.4 0.6 11.1 7.2 146 2 143 305 -20.7 0.1 -20.1 -20.8 02/28/2006 10:50:00 9.7 0.6 11.5 7.6 9.3 0.5 10.7 7.6 142 3 142 305 -20.7 0.2 -20.1 -21 02/28/2006 11:00:00 10.8 0.8 13.3 9.1 10.4 0.7 12.6 8.4 141 3 144 305 -20.3 0.1 -19.9 -20.6 02/28/2006 11:10:00 11.9 0.8 13.3 9.9 11.5 0.8 13 9.1 138 3 133 305 -20.2 0 -19.5 -20.4 02/28/2006 11:20:00 12.4 0.5 13.7 10.3 12 0.6 13.3 10.3 135 2 138 305 -20 0.1 -19.3 -20.1 02/28/2006 11:30:00 12.2 0.7 13.7 9.5 11.9 0.8 14.1 9.5 134 4 137 305 -19.5 0.2 -18.8 -19.9 02/28/2006 11:40:00 12 0.8 14.1 8.8 11.7 0.9 13.7 8.8 136 5 129 305 -19.1 0 -18.4 -19.3 02/28/2006 11:50:00 11.5 0.5 12.6 9.9 11.3 0.5 12.2 9.1 135 3 137 305 -18.9 0.1 -18.6 -19 02/28/2006 12:00:00 11.5 0.8 13.3 9.5 11.3 0.8 13.3 8.8 133 3 137 305 -18.5 0.1 -18.2 -18.8 02/28/2006 12:10:00 12.9 0.6 14.1 11.1 12.4 0.6 13.7 10.7 140 3 139 305 -18.5 0 -18.2 -18.6 02/28/2006 12:20:00 13.9 0.8 15.6 11.5 13.6 0.8 15.3 11.8 136 3 138 305 -18.5 0 -18.4 -18.6 02/28/2006 12:30:00 14 0.7 15.6 11.8 13.7 0.7 15.6 11.8 137 2 136 305 -18.6 0 -18.4 -18.6 02/28/2006 12:40:00 14.3 0.7 15.6 12.2 13.8 0.6 15.3 12.2 136 3 137 305 -18.7 0 -18.4 -18.8 02/28/2006 12:50:00 13.6 0.6 15.3 11.8 13.3 0.7 14.9 11.1 136 3 134 305 -18.7 0 -18.4 -19 02/28/2006 13:00:00 13.8 0.7 15.3 11.5 13.5 0.7 15.3 11.8 135 3 135 305 -18.6 0 -18.2 -18.8 02/28/2006 13:10:00 14.1 0.6 15.6 11.8 13.8 0.6 15.3 11.8 134 3 137 305 -18.6 0 -18.1 -18.6 02/28/2006 13:20:00 14.2 0.6 16.1 11.8 14 0.6 15.6 11.8 135 3 132 305 -18.5 0 -18.4 -18.4 02/28/2006 13:30:00 14.3 0.8 16.1 11.8 14.1 0.8 15.6 11.8 133 3 138 305 -18.5 0 -18.4 -18.4 02/28/2006 13:40:00 14.2 0.7 16.1 11.8 14 0.7 15.6 11.8 132 3 134 305 -18.5 0 -18.2 -18.6 02/28/2006 13:50:00 14.2 0.8 16.4 11.5 14 0.8 15.6 11.8 133 3 136 305 -18.5 0 -18.2 -18.4 02/28/2006 14:00:00 14.1 0.9 16.1 10.3 13.9 0.9 16.4 11.5 130 4 133 305 -18.4 0 -18.1 -18.4 02/28/2006 14:10:00 13.9 1.2 16.8 10.3 13.7 1.2 17.6 11.1 128 6 129 305 -18.1 0.1 -17.7 -18.4 02/28/2006 14:20:00 13.7 1.3 17.2 10.7 13.6 1.3 17.6 10.3 127 7 129 305 -18 0.1 -17.5 -18.1 02/28/2006 14:30:00 13.6 1.3 17.2 9.9 13.4 1.2 16.8 10.3 129 6 121 305 -17.8 0 -17.5 -18.1 02/28/2006 14:40:00 14.3 1 16.8 9.9 14.1 1.1 16.8 9.5 132 5 133 305 -17.6 0 -17.5 -17.9 02/28/2006 14:50:00 14 0.9 17.2 11.5 13.8 0.8 16.4 11.5 131 5 127 305 -17.5 0 -17.5 -17.7 02/28/2006 15:00:00 15.2 1 17.2 12.2 14.9 0.9 17.2 12.2 133 3 131 305 -17.5 0 -17.5 -17.7 02/28/2006 15:10:00 16.1 1.3 20.2 12.2 15.8 1.2 19.9 12.6 130 6 142 305 -17.4 0.1 -17.1 -17.7 02/28/2006 15:20:00 16.2 1.4 20.6 11.8 15.9 1.3 19.9 13 130 6 137 305 -17.3 0 -17.1 -17.5 02/28/2006 15:30:00 15.2 1.2 19.1 11.5 14.9 1.2 19.5 11.8 130 6 129 305 -17.3 0 -16.9 -17.3 02/28/2006 15:40:00 15.6 1.2 19.1 11.8 15.4 1.2 18.7 11.5 130 6 124 305 -17.1 0 -16.9 -17.3 02/28/2006 15:50:00 14.6 1.6 19.5 9.9 14.5 1.5 18.3 10.7 128 8 137 305 -16.8 0 -16.6 -16.9 02/28/2006 16:00:00 14.6 1.6 19.1 10.7 14.5 1.6 19.1 10.3 128 8 122 305 -16.8 0.1 -16.6 -16.9 02/28/2006 16:10:00 15.9 1.1 17.9 12.2 15.6 1 18.7 12.6 130 5 127 305 -16.7 0.1 -16.6 -16.9 02/28/2006 16:20:00 16.1 0.8 18.7 13.3 15.7 0.8 17.9 13.3 131 4 123 305 -16.6 0 -16.6 -16.9 02/28/2006 16:30:00 15.8 1.3 19.5 12.2 15.7 1.2 19.1 12.6 128 8 132 305 -16.8 0.1 -16.6 -16.9 02/28/2006 16:40:00 15.1 1.5 19.9 11.5 15 1.5 19.1 10.7 127 9 132 305 -16.9 0 -16.6 -16.9 02/28/2006 16:50:00 14.7 1.5 19.1 10.7 14.8 1.5 19.1 11.1 122 9 128 305 -16.8 0 -16.6 -16.9 02/28/2006 17:00:00 15.6 1.5 19.9 10.7 15.3 1.5 18.7 11.1 121 8 121 305 -16.6 0.1 -16.4 -16.9 02/28/2006 17:10:00 15.6 2 20.6 10.3 15.4 1.9 20.2 10.3 118 7 112 305 -16.4 0 -16.2 -16.6 02/28/2006 17:20:00 16.5 1.7 21 11.1 16.2 1.7 21 10.3 120 7 131 305 -16.3 0 -16 -16.4 02/28/2006 17:30:00 17.3 1.7 21.4 11.5 17 1.7 21.4 12.2 120 6 116 305 -16.4 0 -16.2 -16.6 02/28/2006 17:40:00 18.4 1.7 21.8 13 18 1.7 21.8 11.8 120 6 126 305 -16.4 0 -16.2 -16.6 02/28/2006 17:50:00 18.4 1.7 22.1 13.3 18.1 1.6 21 13 120 6 121 305 -16.2 0.1 -16 -16.4 02/28/2006 18:00:00 16.4 1.9 21 11.8 16.2 1.8 21.4 9.5 112 8 123 305 -16.1 0 -16 -16.2 02/28/2006 18:10:00 15.5 1.9 21 10.7 15.2 1.8 20.6 10.7 109 10 108 305 -16 0 -15.8 -16.2 02/28/2006 18:20:00 16.1 2.4 22.6 10.3 15.9 2.2 21.8 9.9 111 10 118 305 -15.9 0 -15.8 -16 02/28/2006 18:30:00 16.3 1.7 21 12.2 16.1 1.7 20.2 11.1 118 9 124 305 -15.8 0 -15.6 -16 02/28/2006 18:40:00 16.8 1.8 21.8 11.1 16.5 1.9 21.8 11.5 114 9 121 305 -15.7 0 -15.4 -15.8 02/28/2006 18:50:00 16.3 2 21 11.8 16 2 21 11.8 112 9 106 305 -15.4 0.1 -15 -15.6 02/28/2006 19:00:00 15.9 2 20.6 10.7 15.6 2 20.2 10.7 109 10 113 305 -15.2 0 -15 -15.2 02/28/2006 19:10:00 16.5 2.4 22.1 10.7 16.2 2.3 22.6 10.7 109 10 96 305 -15 0 -14.6 -15.2 02/28/2006 19:20:00 17.4 2.5 23.3 12.2 16.9 2.5 24.8 11.1 109 11 116 305 -15.2 0.1 -14.8 -15.4 02/28/2006 19:30:00 17.9 2.4 24 10.7 17.7 2.4 24.4 9.9 114 12 117 305 -15.3 0 -15 -15.4 02/28/2006 19:40:00 18.9 2.3 24 12.6 18.8 2.3 25.6 12.2 117 11 116 305 -15.3 0 -15 -15.4 02/28/2006 19:50:00 18.1 2.2 25.2 13.3 17.7 2.2 25.2 12.6 112 9 105 305 -15.3 0 -15 -15.4 02/28/2006 20:00:00 17.3 2.3 22.1 9.9 17 2.3 22.6 11.5 110 10 104 305 -15.2 0.1 -14.8 -15.2 02/28/2006 20:10:00 17.5 2.6 24 10.3 17 2.5 23.3 9.9 110 12 106 305 -14.9 0.1 -14.6 -15 02/28/2006 20:20:00 16.4 2.4 22.9 11.1 16 2.5 22.6 9.1 113 11 121 305 -14.7 0 -14.4 -14.8 02/28/2006 20:30:00 16.8 2.3 22.9 9.9 16.5 2.4 24.4 10.3 116 10 110 305 -14.4 0.1 -14.1 -14.6 02/28/2006 20:40:00 18.6 2.5 27.1 12.2 18.4 2.4 24.8 12.6 122 13 131 305 -14.1 0.1 -13.7 -14.3 02/28/2006 20:50:00 18.9 2.5 26.3 12.6 18.7 2.3 26 12.2 121 12 123 305 -13.8 0 -13.7 -14.1 02/28/2006 21:00:00 19.1 2.4 26.3 12.2 18.9 2.4 24 12.2 120 9 128 305 -13.7 0 -13.7 -13.9 02/28/2006 21:10:00 18.7 2.7 25.2 10.7 18.1 2.7 24.4 10.3 120 11 120 305 -13.6 0 -13.3 -13.7 02/28/2006 21:20:00 18.3 2.5 24 11.5 18 2.5 24 11.5 118 10 112 305 -13.5 0 -13.3 -13.7 02/28/2006 21:30:00 17.7 2.5 24.4 11.5 17.6 2.3 24.4 11.8 118 11 110 305 -13.3 0 -12.9 -13.5 02/28/2006 21:40:00 18.9 2.7 29.8 12.6 18.6 2.6 28.3 13 121 11 124 305 -13.1 0 -13.1 -13.3 02/28/2006 21:50:00 19.2 2.7 26.8 12.6 18.9 2.6 27.1 12.2 121 11 130 305 -13.2 0 -13.1 -13.5 02/28/2006 22:00:00 19 2.7 27.5 11.1 18.7 2.8 27.9 10.7 123 13 123 305 -13.3 0 -13.1 -13.5 02/28/2006 22:10:00 19 2.6 25.2 12.6 18.9 2.5 25.2 11.1 122 12 120 305 -13.3 0 -13.1 -13.3 02/28/2006 22:20:00 19.7 2.4 28.7 14.1 19.3 2.5 30.6 13.3 129 11 126 305 -13.2 0 -13.1 -13.3 02/28/2006 22:30:00 20.8 2.3 27.5 14.1 20.3 2.3 27.5 14.1 129 10 155 305 -13.3 0 -13.1 -13.5 02/28/2006 22:40:00 20.4 2.3 26.3 13 20 2.3 27.9 14.1 125 12 120 305 -13.3 0 -13.1 -13.5 02/28/2006 22:50:00 20.7 2.6 30.6 14.5 20.4 2.5 29.8 13.7 129 10 125 305 -13.2 0 -12.9 -13.5 02/28/2006 23:00:00 20.3 2.6 27.1 13.3 19.9 2.6 27.5 13.7 128 12 126 305 -13.1 0 -12.9 -13.3 02/28/2006 23:10:00 19.7 2.5 25.2 12.2 19.5 2.5 25.6 13 123 12 123 305 -13.1 0 -12.9 -13.3 02/28/2006 23:20:00 19.7 2.8 28.7 13.3 19.4 2.8 27.9 11.8 121 10 136 305 -13.2 0 -12.9 -13.5 02/28/2006 23:30:00 19.2 2.6 26.8 12.6 18.7 2.5 24 11.8 122 9 112 305 -13.2 0 -12.9 -13.5 02/28/2006 23:40:00 19 2.4 25.2 13.7 18.7 2.4 24.4 14.1 121 10 123 305 -13.3 0 -13.1 -13.5 02/28/2006 23:50:00 18.7 2.5 26.3 11.1 18.4 2.4 24.4 12.6 120 10 131 305 -13.4 0 -13.1 -13.5 03/01/2006 00:00:00 18.8 2.5 26 12.2 18.5 2.5 24.8 11.8 120 11 108 305 -13.5 0.1 -13.1 -13.7 03/01/2006 00:10:00 18.9 2.6 26.8 12.6 18.6 2.5 25.6 12.2 119 10 121 305 -13.5 0.1 -13.3 -13.7 03/01/2006 00:20:00 18.5 2.5 25.6 12.6 18.2 2.4 24.4 10.7 119 10 110 305 -13.5 0 -13.1 -13.7 03/01/2006 00:30:00 19.2 2.5 26.8 12.6 18.7 2.3 26 12.6 127 12 127 305 -13.4 0 -13.1 -13.5 03/01/2006 00:40:00 22.6 1.7 27.1 18.7 21.6 1.7 26 16.1 131 5 135 305 -13.1 0.1 -12.7 -13.3 03/01/2006 00:50:00 23.3 1.4 26.8 18.3 22.3 1.5 26 18.3 132 4 133 305 -13.1 0 -12.9 -13.3 03/01/2006 01:00:00 23.4 1.5 27.1 19.1 22.4 1.5 26.3 18.7 133 4 133 305 -13 0.1 -12.5 -13.1 03/01/2006 01:10:00 23.4 1.5 27.1 18.3 22.5 1.5 25.6 18.7 133 4 138 305 -12.7 0 -12.5 -12.9 03/01/2006 01:20:00 23.6 1.1 26.3 19.5 22.7 1.3 25.6 18.3 132 4 131 305 -12.6 0 -12.3 -12.7 03/01/2006 01:30:00 23.2 1.3 26 18.7 22.2 1.3 25.2 17.9 131 4 130 305 -12.5 0 -12.1 -12.7 03/01/2006 01:40:00 23 1.3 26.3 17.6 22.2 1.5 25.6 16.4 131 4 132 305 -12.5 0.1 -12.1 -12.5 03/01/2006 01:50:00 23 1.5 26.8 18.3 22.1 1.5 26 17.6 131 4 130 305 -12.4 0.1 -12.1 -12.5 03/01/2006 02:00:00 22.7 1.6 26.3 18.3 21.8 1.5 25.2 17.9 130 4 126 305 -12.2 0 -11.9 -12.5 03/01/2006 02:10:00 22.8 1.2 25.2 19.5 22 1.2 24.8 17.9 131 4 131 305 -12.1 0.1 -11.7 -12.5 03/01/2006 02:20:00 22.9 1.5 26 18.3 22.1 1.5 25.2 17.9 131 4 131 305 -11.8 0.1 -11.5 -12.1 03/01/2006 02:30:00 23.2 1.3 26.8 19.5 22.1 1.4 25.2 18.3 131 4 133 305 -11.6 0.1 -11.3 -11.9 03/01/2006 02:40:00 22.8 1.4 26.3 19.1 21.9 1.4 24.8 18.7 131 4 127 305 -11.4 0 -11.1 -11.7 03/01/2006 02:50:00 21.8 1.5 27.1 17.9 21.2 1.5 25.6 17.2 130 5 130 305 -11.3 0.1 -10.9 -11.5 03/01/2006 03:00:00 21.5 1.4 25.2 17.9 20.8 1.3 24 16.4 130 4 124 305 -11.1 0 -10.7 -11.3 03/01/2006 03:10:00 21.4 1.5 24.4 17.2 20.7 1.5 24 16.8 129 5 130 305 -10.9 0 -10.4 -11.1 03/01/2006 03:20:00 21.6 1.5 24.8 17.2 20.8 1.5 24 16.4 131 4 129 305 -10.8 0.1 -10.4 -11.1 03/01/2006 03:30:00 21.2 1.5 24.8 16.4 20.4 1.5 25.2 16.8 131 5 134 305 -10.7 0 -10.4 -10.9 03/01/2006 03:40:00 21.6 1.4 24.8 17.2 20.7 1.5 24.4 16.4 130 4 131 305 -10.7 0 -10.2 -10.9 03/01/2006 03:50:00 20.9 1.5 24 15.3 20 1.3 23.7 16.1 130 4 135 305 -10.7 0 -10.2 -10.9 03/01/2006 04:00:00 21.3 1.4 24 17.2 20.5 1.3 22.9 15.6 130 4 134 305 -10.7 0 -10.4 -10.9 03/01/2006 04:10:00 20.6 1.5 24 16.8 19.9 1.5 24.4 14.9 131 5 133 305 -10.3 0 -10 -10.7 03/01/2006 04:20:00 20.9 1.4 26 16.4 20.2 1.3 24 16.4 131 5 126 305 -10.1 0 -9.6 -10.4 03/01/2006 04:30:00 20.6 1.8 25.2 14.9 19.9 1.8 24.8 13.7 131 6 128 305 -10 0 -9.6 -10.2 03/01/2006 04:40:00 21 1.5 25.2 16.8 20.3 1.6 24.8 16.1 131 4 136 305 -9.9 0 -9.6 -10 03/01/2006 04:50:00 20.6 1.9 25.2 16.1 19.9 1.8 24.4 15.3 131 5 123 305 -9.8 0 -9.2 -9.8 03/01/2006 05:00:00 20.4 1.8 24.8 14.5 19.7 1.9 24.8 13.7 130 6 129 305 -9.6 0.1 -9.2 -9.8 03/01/2006 05:10:00 20.6 1.5 24.8 16.4 20 1.5 23.7 16.1 130 5 137 305 -9.5 0 -9.2 -9.6 03/01/2006 05:20:00 19.7 1.7 23.3 14.5 19.1 1.7 22.9 13.3 130 5 135 305 -9.3 0 -8.8 -9.6 03/01/2006 05:30:00 19.4 1.5 23.3 14.5 18.7 1.5 24.4 13.7 131 5 117 305 -9.2 0.1 -8.8 -9.2 03/01/2006 05:40:00 18.9 1.9 25.2 14.5 18.4 1.7 24.8 14.1 130 8 127 305 -9 0 -8.6 -9.2 03/01/2006 05:50:00 19.2 1.7 24 14.1 18.6 1.8 23.3 14.5 130 7 130 305 -8.9 0 -8.6 -9.2 03/01/2006 06:00:00 19.2 1.8 23.7 13.3 18.5 1.8 22.9 14.1 130 6 129 305 -8.8 0 -8.4 -9 03/01/2006 06:10:00 16.9 2.6 22.9 9.9 16.6 2.5 22.6 10.7 130 11 138 305 -8.7 0 -8.4 -8.8 03/01/2006 06:20:00 18.3 2 24 13.3 17.9 2 24 12.6 130 8 133 305 -8.7 0.1 -8.2 -8.8 03/01/2006 06:30:00 17.9 1.9 22.6 12.6 17.8 2 23.7 11.8 131 10 144 305 -8.5 0 -8.2 -8.6 03/01/2006 06:40:00 16.4 2.3 22.1 11.1 16 2.3 23.3 9.9 129 11 130 305 -8.4 0 -8.2 -8.6 03/01/2006 06:50:00 16.4 2 21.8 12.2 15.9 2.1 21 9.5 131 10 134 305 -8.4 0 -8.2 -8.6 03/01/2006 07:00:00 17.6 1.7 21.4 12.6 17.3 1.7 20.6 11.8 130 7 124 305 -8.3 0 -7.9 -8.4 03/01/2006 07:10:00 17.6 1.8 22.6 13 17.1 1.7 22.1 13 130 8 139 305 -8.2 0 -7.7 -8.4 03/01/2006 07:20:00 17.6 1.4 21.4 14.1 17 1.4 21 12.6 131 5 122 305 -8.2 0 -7.7 -8.2 03/01/2006 07:30:00 17.8 1.1 20.6 14.9 17.1 1.2 19.9 13.3 132 5 131 305 -8.1 0.1 -7.7 -8.2 03/01/2006 07:40:00 18.1 1.4 21 13.3 17.5 1.4 20.6 11.8 131 5 128 305 -7.9 0 -7.5 -8.2 03/01/2006 07:50:00 18.1 1.2 21.4 14.9 17.5 1.1 20.6 14.1 131 5 133 305 -7.8 0 -7.5 -7.9 03/01/2006 08:00:00 17.1 1.5 22.6 12.2 16.6 1.4 19.9 12.2 130 5 127 305 -7.7 0 -7.3 -7.7 03/01/2006 08:10:00 17.2 1.3 20.6 13 16.6 1.3 19.5 12.2 130 5 129 305 -7.6 0.1 -7.1 -7.7 03/01/2006 08:20:00 16.9 1.2 19.9 12.6 16.3 1.3 19.1 13 131 4 128 305 -7.4 0 -7.1 -7.5 03/01/2006 08:30:00 16.3 1.1 18.7 13 15.7 1 18.3 13 132 4 129 305 -7.2 0 -6.9 -7.5 03/01/2006 08:40:00 15.8 1 18.7 12.6 15.2 0.9 17.6 12.6 133 4 131 305 -7.1 0 -6.9 -7.3 03/01/2006 08:50:00 16.2 1.1 19.5 13.7 15.7 1 18.7 12.2 133 4 132 305 -6.9 0.1 -6.7 -7.1 03/01/2006 09:00:00 16.2 1.1 18.7 13 15.7 1 18.3 13 134 4 138 305 -6.8 0 -6.7 -6.9 03/01/2006 09:10:00 15.5 1 17.9 12.6 15.1 0.9 17.6 12.6 134 4 133 305 -6.7 0 -6.7 -6.9 03/01/2006 09:20:00 15.6 1 17.9 12.2 15 1 17.6 12.2 134 4 138 305 -6.6 0 -6.4 -6.9 03/01/2006 09:30:00 15 1 17.6 12.2 14.6 1 17.2 11.8 134 4 133 305 -6.5 0 -6.4 -6.7 03/01/2006 09:40:00 15 1 17.2 12.2 14.6 1 16.8 12.2 134 4 129 305 -6.4 0 -6.2 -6.7 03/01/2006 09:50:00 15 0.9 17.2 13 14.7 0.8 16.4 12.6 134 4 132 305 -6.4 0 -6.2 -6.7 03/01/2006 10:00:00 15.1 1.1 17.6 11.8 14.7 1 17.2 11.8 135 4 136 305 -6.3 0 -6 -6.4 03/01/2006 10:10:00 14.8 1 17.2 12.2 14.3 1 16.4 12.2 134 3 143 305 -6.1 0 -5.8 -6.4 03/01/2006 10:20:00 14.8 0.9 16.8 11.5 14.3 0.8 16.8 12.2 133 3 136 305 -6 0 -5.8 -6.2 03/01/2006 10:30:00 14.4 0.8 16.4 12.6 14 0.8 16.1 11.8 133 3 135 305 -6 0 -5.8 -6 03/01/2006 10:40:00 14.4 0.8 16.1 12.2 14 0.7 15.6 11.8 134 3 134 305 -5.9 0 -5.8 -6 03/01/2006 10:50:00 14.3 0.8 16.1 11.8 13.8 0.8 15.6 11.5 133 3 141 305 -5.8 0 -5.6 -6 03/01/2006 11:00:00 13.9 0.8 15.6 11.8 13.5 0.8 15.6 11.5 134 3 135 305 -5.7 0 -5.6 -5.8 03/01/2006 11:10:00 14 0.9 16.4 11.1 13.5 0.8 16.1 11.5 135 3 131 305 -5.5 0 -5.3 -5.8 03/01/2006 11:20:00 13.6 0.8 15.3 11.1 13.1 0.8 14.9 11.1 136 3 139 305 -5.5 0 -5.1 -5.6 03/01/2006 11:30:00 13.1 0.8 14.9 11.1 12.7 0.8 14.9 10.7 136 3 134 305 -5.3 0 -5.1 -5.6 03/01/2006 11:40:00 12.6 0.7 14.5 9.9 12.2 0.7 13.7 9.9 137 3 143 305 -5.2 0 -4.9 -5.3 03/01/2006 11:50:00 12.3 0.7 14.1 10.7 11.8 0.8 13.7 9.5 138 3 138 305 -5 0 -4.7 -5.1 03/01/2006 12:00:00 11.7 0.6 13.3 9.5 11.2 0.6 12.6 9.5 140 3 140 305 -4.8 0 -4.5 -4.9 03/01/2006 12:10:00 11.1 0.7 13 9.1 10.6 0.6 12.2 8.8 142 3 144 305 -4.6 0 -4.5 -4.7 03/01/2006 12:20:00 10.5 0.7 12.2 8.4 10.1 0.7 11.5 8.4 144 3 139 305 -4.4 0.1 -4 -4.7 03/01/2006 12:30:00 9.7 0.6 11.8 8 9.3 0.6 11.1 7.2 144 4 150 305 -4 0 -3.8 -4.2 03/01/2006 12:40:00 8.7 0.7 10.3 6.8 8.4 0.7 9.9 6.5 148 5 147 305 -3.7 0 -3.6 -3.8 03/01/2006 12:50:00 6.7 2 10.3 3 7.6 0.8 9.5 5.7 160 9 151 305 -3.5 0 -3.1 -3.8 03/01/2006 13:00:00 5.8 0.9 7.2 2.6 6.3 0.5 7.6 4.9 185 9 187 305 -2.7 0.3 -2.2 -3.3 03/01/2006 13:10:00 5.6 0.6 6.8 3.4 5.7 0.5 7.2 3.8 192 8 197 305 -2.3 0 -2.2 -2.4 03/01/2006 13:20:00 4.5 0.5 5.7 3.4 4 0.7 5.7 2.3 224 22 193 305 -2.2 0 -2 -2.4 03/01/2006 13:30:00 4.6 0.5 5.7 3 3.5 0.6 4.9 1.9 249 6 246 305 -2 0 -2 -2.2 03/01/2006 13:40:00 4.5 0.5 5.7 3 3.1 0.7 4.6 1.1 253 6 254 305 -2.2 0 -2 -2.4 03/01/2006 13:50:00 4.8 0.7 5.7 3 3.5 0.6 4.9 1.5 255 5 252 305 -2.2 0 -2 -2.4 03/01/2006 14:00:00 4.1 0.6 5.3 2.3 2.7 0.6 4.2 1.1 259 8 254 305 -2.4 0 -2.2 -2.4 03/01/2006 14:10:00 5 0.5 6.1 3.4 3.5 0.6 4.9 1.9 259 5 264 305 -2.4 0.1 -2 -2.7 03/01/2006 14:20:00 4.3 0.5 5.3 3 3.3 0.6 4.9 1.9 252 5 256 305 -2.7 0 -2.2 -2.9 03/01/2006 14:30:00 4.6 0.5 5.3 3 3.6 0.6 4.9 1.9 252 7 246 305 -2.8 0 -2.4 -3.1 03/01/2006 14:40:00 3.6 0.6 5.3 1.9 2.3 0.6 4.2 1.1 257 8 258 305 -2.8 0 -2.4 -3.1 03/01/2006 14:50:00 3 0.5 4.2 1.9 2 0.6 3.8 0.4 254 9 244 305 -2.9 0 -2.7 -3.1 03/01/2006 15:00:00 2.7 0.6 3.8 1.5 1.5 0.6 3 0.4 260 10 255 305 -2.8 0 -2.4 -3.1 03/01/2006 15:10:00 2.8 0.5 4.2 1.5 1.8 0.7 3.4 0.4 255 8 256 305 -2.8 0 -2.4 -2.9 03/01/2006 15:20:00 3.6 0.7 4.9 1.9 2.9 0.8 4.6 0.7 245 6 242 305 -2.8 0 -2.7 -3.1 03/01/2006 15:30:00 3.9 0.4 4.9 2.6 3 0.5 4.2 1.5 254 8 271 305 -2.8 0 -2.4 -3.1 03/01/2006 15:40:00 4.2 0.5 5.3 3 3 0.5 4.2 1.5 256 6 268 305 -3 0.2 -2.7 -3.3 03/01/2006 15:50:00 3.6 0.6 4.9 1.5 2.3 0.6 3.4 0.7 266 7 266 305 -3.3 0 -2.7 -3.3 03/01/2006 16:00:00 3 0.6 4.2 1.1 2 0.7 3.8 0.4 270 9 266 305 -3.5 0 -3.1 -3.8 03/01/2006 16:10:00 3.9 0.3 4.6 3 3.6 0.4 4.2 2.3 296 12 285 305 -3.8 0.1 -3.1 -4.2 03/01/2006 16:20:00 3.2 0.3 4.2 2.6 2.9 0.4 3.8 1.9 309 19 303 305 -4.3 0.1 -3.8 -4.7 03/01/2006 16:30:00 2.7 0.3 3.4 1.9 2.3 0.4 3.4 1.5 309 18 325 305 -4.6 0 -4.2 -4.7 03/01/2006 16:40:00 3 0.5 4.2 1.9 2.7 0.7 4.2 1.1 312 17 317 305 -4.7 0 -4.2 -4.9 03/01/2006 16:50:00 4 0.5 4.9 2.6 3.8 0.5 4.6 2.3 309 27 295 305 -5 0.1 -4.5 -5.3 03/01/2006 17:00:00 4.1 0.5 5.7 2.6 4 0.6 5.3 3 311 19 303 305 -5.5 0 -5.3 -5.8 03/01/2006 17:10:00 3.7 0.3 4.2 2.3 3.5 0.4 4.2 2.3 315 19 290 305 -5.8 0 -5.6 -6 03/01/2006 17:20:00 3.3 0.5 4.2 2.3 3.1 0.6 4.2 1.9 323 5 323 305 -6.2 0 -5.8 -6.4 03/01/2006 17:30:00 2.8 0.3 3.4 1.9 2.5 0.4 3.4 1.5 324 6 325 305 -6.3 0 -6 -6.4 03/01/2006 17:40:00 2.2 0.4 3 1.5 1.8 0.5 2.6 0.4 323 8 308 305 -6.2 0 -6 -6.4 03/01/2006 17:50:00 2.7 0.4 3.4 1.5 2.4 0.5 3.4 1.1 323 7 313 305 -6.2 0 -6 -6.4 03/01/2006 18:00:00 2.9 0.4 3.8 2.3 2.6 0.5 3.8 1.5 328 3 325 305 -6.4 0.1 -6 -6.7 03/01/2006 18:10:00 2.4 0.3 3 1.9 2 0.4 2.6 1.1 327 5 324 305 -6.5 0 -6 -6.7 03/01/2006 18:20:00 2.3 0.3 3 1.9 1.9 0.3 3 1.1 333 5 340 305 -6.7 0 -6.4 -6.9 03/01/2006 18:30:00 2.2 0.2 2.6 1.9 1.8 0.3 2.3 1.1 329 6 334 305 -6.8 0 -6.2 -6.9 03/01/2006 18:40:00 2.1 0.3 2.6 1.5 1.6 0.4 2.3 0.7 328 4 322 305 -6.9 0 -6.7 -7.1 03/01/2006 18:50:00 2 0.2 2.6 1.5 1.5 0.2 2.3 1.1 324 6 320 305 -7 0 -6.7 -7.1 03/01/2006 19:00:00 2.2 0.3 3 1.1 1.9 0.4 2.6 0.7 329 5 326 305 -7.1 0 -6.7 -7.3 03/01/2006 19:10:00 1.9 0.3 2.6 1.1 1.5 0.4 2.6 0.7 321 6 327 305 -7.3 0 -7.1 -7.3 03/01/2006 19:20:00 1.9 0.3 2.6 1.5 1.5 0.3 2.3 0.7 324 6 305 305 -7.5 0 -7.3 -7.7 03/01/2006 19:30:00 1.6 0.3 2.3 1.1 1.2 0.4 2.3 0.4 336 3 328 305 -7.6 0 -7.3 -7.7 03/01/2006 19:40:00 1.8 0.3 2.3 1.1 1.3 0.4 2.3 0.4 340 0 340 305 -7.6 0 -7.3 -7.7 03/01/2006 19:50:00 1.8 0.3 2.3 1.1 1.4 0.3 2.3 0.4 340 0 340 305 -7.7 0 -7.5 -7.7 03/01/2006 20:00:00 2 0.3 2.6 1.5 1.6 0.3 2.3 1.1 21 7 340 305 -7.7 0 -7.1 -7.9 03/01/2006 20:10:00 1.6 0.3 2.3 1.1 1 0.4 1.9 0.4 22 0 22 305 -7.7 0 -7.5 -7.7 03/01/2006 20:20:00 1.6 0.3 2.3 0.7 1 0.4 1.9 0.4 22 0 22 305 -7.6 0 -7.3 -7.7 03/01/2006 20:30:00 1.1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 22 0 22 305 -7.5 0 -7.3 -7.7 03/01/2006 20:40:00 1.8 0.3 2.6 1.1 1.4 0.4 2.3 0.7 22 0 22 305 -7.5 0 -7.3 -7.5 03/01/2006 20:50:00 2 0.3 2.6 1.5 1.6 0.4 2.6 1.1 22 0 22 305 -7.5 0 -7.3 -7.7 03/01/2006 21:00:00 1.6 0.2 2.3 1.1 1.1 0.3 1.9 0.4 22 0 22 305 -7.4 0 -7.3 -7.5 03/01/2006 21:10:00 2 0.2 2.3 1.5 1.6 0.3 2.3 0.7 21 0 22 305 -7.5 0 -7.3 -7.7 03/01/2006 21:20:00 1.6 0.4 2.3 0.7 1.2 0.5 2.3 0.4 21 0 22 305 -7.6 0 -7.3 -7.7 03/01/2006 21:30:00 2.4 0.4 3.4 1.1 2.1 0.5 3 0.7 21 0 22 305 -7.7 0 -7.5 -8.2 03/01/2006 21:40:00 2 0.3 2.6 1.1 1.6 0.4 2.6 0.4 21 0 21 305 -7.9 0 -7.7 -8.2 03/01/2006 21:50:00 2.5 0.4 3.4 1.5 2.2 0.6 3.4 0.7 21 0 21 305 -8 0 -7.9 -8.2 03/01/2006 22:00:00 3 0.4 3.8 1.9 2.8 0.5 3.8 1.9 21 0 21 305 -8.2 0 -7.9 -8.4 03/01/2006 22:10:00 3.6 0.3 4.6 2.6 3.6 0.3 4.2 2.3 21 0 21 305 -8.4 0 -8.2 -8.6 03/01/2006 22:20:00 3.8 0.3 4.6 3 3.7 0.3 4.6 2.6 21 0 21 305 -8.5 0.1 -8.4 -8.8 03/01/2006 22:30:00 3.7 0.4 4.6 2.6 3.6 0.4 4.6 2.3 21 0 21 305 -8.7 0 -8.4 -8.8 03/01/2006 22:40:00 3.6 0.3 4.6 2.6 3.4 0.4 4.2 1.9 21 0 21 305 -8.5 0 -8.2 -8.8 03/01/2006 22:50:00 3.9 0.4 4.9 3 3.8 0.5 4.9 2.6 21 0 21 305 -8.3 0 -8.2 -8.6 03/01/2006 23:00:00 4.1 0.4 4.9 3 4 0.4 4.9 3 21 0 21 305 -8.4 0 -8.2 -8.4 03/01/2006 23:10:00 3.9 0.3 4.6 3 3.8 0.4 4.6 3 21 0 21 305 -8.3 0 -8.2 -8.4 03/01/2006 23:20:00 4.4 0.3 4.9 3.4 4.4 0.3 5.3 3.4 21 0 22 305 -8.3 0 -8.2 -8.4 03/01/2006 23:30:00 4.6 0.3 5.3 3.8 4.5 0.4 5.7 3.4 22 0 22 305 -8.4 0 -8.2 -8.6 03/01/2006 23:40:00 4.9 0.4 6.1 4.2 5 0.4 6.1 4.2 22 0 22 305 -8.5 0 -8.4 -8.6 03/01/2006 23:50:00 4.8 0.3 5.7 4.2 4.7 0.4 5.7 3.8 22 0 22 305 -8.5 0 -8.4 -8.6 03/02/2006 00:00:00 4.7 0.3 5.3 3.8 4.6 0.3 5.7 3.8 22 0 22 305 -8.4 0 -8.2 -8.4 03/02/2006 00:10:00 4.5 0.4 5.3 3.4 4.3 0.4 5.3 3.4 22 0 22 305 -8.3 0 -8.2 -8.4 03/02/2006 00:20:00 4.5 0.4 5.3 3 4.2 0.5 5.3 3 22 0 22 305 -8.3 0 -8.2 -8.4 03/02/2006 00:30:00 4.6 0.6 5.7 3 4.4 0.7 5.7 2.6 23 0 23 305 -8.3 0 -8.2 -8.4 03/02/2006 00:40:00 5.1 0.4 6.1 4.2 5 0.5 6.1 3 23 0 23 305 -8.2 0 -8.2 -8.4 03/02/2006 00:50:00 4.9 0.4 6.1 3.4 4.7 0.5 6.1 3 23 0 23 305 -8.3 0 -8.2 -8.4 03/02/2006 01:00:00 5 0.6 6.5 3.4 4.8 0.7 6.1 3.4 23 0 23 305 -8.3 0 -8.2 -8.4 03/02/2006 01:10:00 5 0.5 6.5 3.8 4.8 0.6 6.5 3 24 0 24 305 -8.4 0 -8.2 -8.6 03/02/2006 01:20:00 5.3 0.5 6.5 4.2 5.2 0.5 6.5 3.8 24 0 24 305 -8.4 0 -8.2 -8.6 03/02/2006 01:30:00 5.5 0.4 6.5 4.2 5.3 0.4 6.5 4.2 25 0 24 305 -8.3 0 -8.2 -8.4 03/02/2006 01:40:00 4.4 0.5 5.7 3 4.1 0.6 5.3 2.6 25 0 25 305 -8.2 0 -7.9 -8.4 03/02/2006 01:50:00 4.7 0.5 5.7 3.4 4.5 0.6 5.7 3 25 0 25 305 -8.2 0 -7.9 -8.2 03/02/2006 02:00:00 4.8 0.3 5.7 3.8 4.7 0.5 5.7 3.4 25 0 25 305 -8.1 0 -7.7 -8.2 03/02/2006 02:10:00 5.2 0.5 6.1 3.8 5.1 0.6 6.5 3.4 26 0 25 305 -8.1 0 -7.7 -8.2 03/02/2006 02:20:00 4.7 0.6 5.7 3 4.6 0.7 5.7 2.6 26 0 26 305 -8.1 0 -7.7 -8.2 03/02/2006 02:30:00 4.3 0.4 4.9 2.6 4 0.4 4.9 2.6 26 0 26 305 -8 0 -7.7 -8.2 03/02/2006 02:40:00 4.6 0.4 5.3 3.4 4.4 0.4 5.3 2.6 26 0 26 305 -7.9 0 -7.7 -8.2 03/02/2006 02:50:00 4.4 0.5 5.7 3.4 4.2 0.6 5.7 3 26 0 26 305 -7.8 0 -7.5 -7.9 03/02/2006 03:00:00 4.4 0.5 5.3 2.6 4.1 0.6 4.9 2.3 26 0 27 305 -7.7 0 -7.5 -7.9 03/02/2006 03:10:00 5.4 0.6 6.8 3.8 5.2 0.7 7.2 3 27 0 27 305 -7.7 0 -7.3 -7.7 03/02/2006 03:20:00 5.8 0.5 6.5 3.8 5.5 0.5 6.5 3.4 27 0 27 305 -7.7 0 -7.3 -7.7 03/02/2006 03:30:00 5.7 0.4 6.5 4.2 5.4 0.5 6.5 3.4 27 0 27 305 -7.6 0.1 -7.3 -7.7 03/02/2006 03:40:00 5.2 0.4 6.1 4.2 5 0.4 6.1 3.4 27 0 27 305 -7.5 0 -7.1 -7.7 03/02/2006 03:50:00 4.9 0.3 5.7 3.8 4.9 0.4 6.1 3.8 27 0 27 305 -7.4 0 -7.1 -7.5 03/02/2006 04:00:00 5.3 0.4 6.5 4.6 5.3 0.4 6.5 4.2 28 0 28 305 -7.4 0 -7.1 -7.5 03/02/2006 04:10:00 5.2 0.4 6.1 4.2 5.1 0.4 6.5 3.4 28 0 27 305 -7.4 0 -7.3 -7.5 03/02/2006 04:20:00 5.5 0.5 6.5 4.2 5.2 0.5 6.1 4.2 28 0 28 305 -7.5 0 -7.3 -7.7 03/02/2006 04:30:00 5.8 0.5 6.8 4.6 5.7 0.5 6.8 4.2 28 0 28 305 -7.5 0 -7.3 -7.7 03/02/2006 04:40:00 6.3 0.4 7.2 5.3 6.2 0.5 7.2 4.9 28 0 28 305 -7.6 0 -7.3 -7.7 03/02/2006 04:50:00 6.4 0.4 7.2 5.3 6.2 0.4 7.2 4.6 28 0 28 305 -7.6 0 -7.3 -7.7 03/02/2006 05:00:00 6.7 0.8 8.4 4.6 6.4 0.9 8.4 4.2 28 0 29 305 -7.7 0 -7.5 -7.7 03/02/2006 05:10:00 7.2 0.6 8.4 5.3 7.1 0.6 8.4 5.3 29 0 29 305 -7.7 0 -7.7 -7.7 03/02/2006 05:20:00 6.4 0.6 8 4.6 6 0.7 8 4.2 29 0 29 305 -7.7 0 -7.7 -7.9 03/02/2006 05:30:00 6.4 0.7 8.4 4.2 5.9 0.7 7.6 3.4 29 0 29 305 -7.7 0 -7.5 -7.7 03/02/2006 05:40:00 8 0.7 9.5 6.1 7.5 0.6 8.8 5.7 29 0 29 305 -7.6 0 -7.3 -7.7 03/02/2006 05:50:00 8.4 0.5 9.5 6.5 7.9 0.5 9.1 6.1 30 0 30 305 -7.6 0 -7.5 -7.7 03/02/2006 06:00:00 8.2 0.5 9.5 6.5 7.7 0.6 9.5 6.1 31 0 31 305 -7.6 0 -7.5 -7.7 03/02/2006 06:10:00 7.9 0.5 9.9 6.8 7.4 0.5 8.8 5.7 32 0 32 305 -7.7 0 -7.5 -7.7 03/02/2006 06:20:00 8.2 0.6 9.5 6.5 7.7 0.6 8.8 6.1 33 0 33 305 -7.6 0 -7.5 -7.7 03/02/2006 06:30:00 8.8 0.4 9.9 7.2 8.4 0.4 9.5 6.8 34 0 34 305 -7.6 0 -7.3 -7.7 03/02/2006 06:40:00 9 0.4 9.9 7.2 8.4 0.5 9.5 6.8 36 1 36 305 -7.5 0 -7.3 -7.7 03/02/2006 06:50:00 9.2 0.4 10.3 8 8.6 0.5 9.9 7.2 38 1 39 305 -7.5 0 -7.3 -7.7 03/02/2006 07:00:00 9.2 0.6 10.7 7.2 8.5 0.5 9.9 6.8 74 30 98 305 -7.4 0 -7.1 -7.5 03/02/2006 07:10:00 9.2 0.5 10.3 7.6 8.5 0.5 9.5 7.2 102 3 105 305 -7.5 0 -7.1 -7.7 03/02/2006 07:20:00 9 0.5 10.3 7.6 8.3 0.5 9.5 6.8 103 3 101 305 -7.4 0 -7.1 -7.7 03/02/2006 07:30:00 9 0.4 9.9 8 8.3 0.4 9.5 7.2 104 3 110 305 -7.4 0 -7.1 -7.5 03/02/2006 07:40:00 8.6 0.5 9.5 7.6 7.8 0.4 9.1 6.8 100 3 102 305 -7.5 0 -7.1 -7.7 03/02/2006 07:50:00 8.5 0.4 9.5 7.2 7.7 0.4 8.8 6.5 97 3 95 305 -7.5 0 -7.1 -7.7 03/02/2006 08:00:00 7.8 0.6 9.5 6.1 7.2 0.7 8.4 5.3 96 5 99 305 -7.5 0 -7.3 -7.7 03/02/2006 08:10:00 5.4 0.9 7.2 3.4 5.1 0.7 6.5 3 54 24 85 305 -7.5 0 -7.3 -7.7 03/02/2006 08:20:00 5.5 0.4 6.8 4.2 5.5 0.5 6.8 4.2 42 8 45 305 -7.4 0 -7.3 -7.5 03/02/2006 08:30:00 5.5 0.6 6.8 3.4 5.3 0.6 6.5 3.4 51 9 48 305 -7.3 0 -7.1 -7.3 03/02/2006 08:40:00 6.3 0.5 7.6 4.2 6.1 0.6 7.6 4.2 56 5 51 305 -7.3 0 -7.1 -7.5 03/02/2006 08:50:00 7 0.5 8 5.3 6.8 0.6 8 4.9 56 3 56 305 -7.4 0 -7.3 -7.5 03/02/2006 09:00:00 7.3 0.5 8.4 5.7 7.2 0.7 8.8 4.9 55 3 55 305 -7.4 0 -7.1 -7.5 03/02/2006 09:10:00 7.5 0.5 8.8 5.7 7.3 0.6 8.8 5.7 58 4 56 305 -7.4 0 -7.1 -7.5 03/02/2006 09:20:00 7.3 0.7 8.8 5.7 7.1 0.8 8.8 5.3 55 4 58 305 -7.6 0 -7.3 -7.7 03/02/2006 09:30:00 7 0.5 8.4 5.7 6.8 0.6 8.4 5.3 56 4 48 305 -7.6 0 -7.3 -7.7 03/02/2006 09:40:00 6.9 0.5 8 5.7 6.6 0.5 7.6 4.9 58 4 62 305 -7.5 0 -7.3 -7.7 03/02/2006 09:50:00 5.9 0.7 7.2 3.8 5.7 0.7 7.2 3.4 47 6 53 305 -7.6 0 -7.3 -7.9 03/02/2006 10:00:00 5.7 1 7.6 2.6 5.5 1.1 7.6 2.6 45 7 40 305 -7.8 0 -7.5 -8.2 03/02/2006 10:10:00 6.1 0.6 7.6 4.6 6.1 0.6 7.6 4.6 44 5 37 305 -8 0.1 -7.7 -8.2 03/02/2006 10:20:00 6.8 0.6 8 5.3 6.7 0.7 8.4 4.6 48 5 48 305 -8.2 0 -7.7 -8.4 03/02/2006 10:30:00 6.8 0.6 8.4 4.9 6.6 0.7 8.4 4.6 53 5 52 305 -8.4 0 -8.2 -8.6 03/02/2006 10:40:00 7.9 0.5 8.8 6.5 8 0.5 9.1 6.1 52 3 56 305 -8.5 0 -8.2 -8.6 03/02/2006 10:50:00 8 0.5 9.5 6.5 8.1 0.5 9.1 6.1 55 5 63 305 -8.4 0 -8.2 -8.6 03/02/2006 11:00:00 7.2 0.5 8.4 5.7 7 0.6 8.4 4.9 57 5 64 305 -8.3 0 -8.2 -8.4 03/02/2006 11:10:00 7.7 0.6 8.8 5.3 7.6 0.7 9.1 5.3 55 5 56 305 -8.2 0 -7.9 -8.4 03/02/2006 11:20:00 7 0.7 8 4.6 6.7 0.8 8.4 4.6 47 5 47 305 -8.2 0 -7.9 -8.4 03/02/2006 11:30:00 7.4 0.7 8.8 5.3 7.3 0.8 8.8 4.9 53 5 49 305 -8 0.1 -7.7 -8.4 03/02/2006 11:40:00 7.9 0.5 9.1 6.5 7.9 0.5 9.1 6.5 53 4 54 305 -8 0.1 -7.7 -8.2 03/02/2006 11:50:00 6.6 0.8 8 4.6 6.4 0.8 8 4.2 49 7 57 305 -8.1 0 -7.7 -8.2 03/02/2006 12:00:00 6.5 0.9 8.4 4.2 6.3 1 8.8 3.4 43 7 44 305 -8 0.1 -7.7 -8.2 03/02/2006 12:10:00 6.8 0.7 8.4 4.9 6.7 0.8 8.4 4.6 47 6 53 305 -7.9 0 -7.5 -8.2 03/02/2006 12:20:00 6.9 0.7 8.8 4.9 6.8 0.8 8.8 4.6 46 5 45 305 -7.9 0.1 -7.7 -8.2 03/02/2006 12:30:00 7.7 0.7 9.1 5.7 7.6 0.8 9.1 5.3 49 4 51 305 -8 0.1 -7.7 -8.2 03/02/2006 12:40:00 8.1 0.5 9.1 6.5 8.1 0.5 9.1 6.1 53 4 50 305 -8 0.1 -7.7 -8.2 03/02/2006 12:50:00 7.4 0.5 8.8 5.7 7.3 0.7 8.4 5.7 49 4 48 305 -8 0.1 -7.7 -8.2 03/02/2006 13:00:00 7.5 0.5 8.8 6.1 7.3 0.6 8.8 5.7 44 5 46 305 -8.1 0.1 -7.7 -8.2 03/02/2006 13:10:00 7.3 0.6 8.8 5.3 7.1 0.8 8.8 4.9 48 5 48 305 -8.1 0 -7.7 -8.2 03/02/2006 13:20:00 6.9 0.7 8.8 5.3 6.8 0.8 8.8 4.6 50 5 51 305 -8 0.1 -7.7 -8.2 03/02/2006 13:30:00 7.4 0.7 8.8 4.6 7.4 0.8 9.1 4.9 50 5 48 305 -8.1 0.1 -7.7 -8.2 03/02/2006 13:40:00 7.8 0.5 8.8 5.7 7.9 0.7 9.1 5.7 48 4 51 305 -8.2 0 -7.9 -8.4 03/02/2006 13:50:00 8 0.5 9.1 6.5 8 0.7 9.5 6.1 48 3 47 305 -8.2 0 -7.9 -8.4 03/02/2006 14:00:00 7.7 0.6 8.8 5.7 7.6 0.8 9.1 4.9 50 5 54 305 -8.2 0 -7.9 -8.4 03/02/2006 14:10:00 8.3 0.7 9.5 6.1 8.2 0.8 9.9 5.7 50 5 47 305 -8.1 0 -7.9 -8.2 03/02/2006 14:20:00 7.3 0.7 8.8 4.9 7.2 0.8 9.1 4.9 44 5 44 305 -7.9 0 -7.7 -8.2 03/02/2006 14:30:00 6.6 0.7 8 4.9 6.5 0.8 8.4 4.6 42 6 40 305 -7.8 0 -7.7 -7.9 03/02/2006 14:40:00 7.4 0.6 8.8 5.7 7.4 0.7 9.1 5.3 49 5 46 305 -8 0.1 -7.7 -8.2 03/02/2006 14:50:00 7.4 0.8 9.1 5.3 7.2 0.9 8.8 4.6 49 5 51 305 -8.2 0 -8.2 -8.4 03/02/2006 15:00:00 6 0.7 7.6 4.6 5.7 0.8 7.6 4.2 40 8 37 305 -8.2 0 -7.9 -8.4 03/02/2006 15:10:00 6.4 0.6 8.4 4.6 6.2 0.6 8 4.6 30 5 31 305 -8.7 0 -8.4 -9 03/02/2006 15:20:00 6.1 0.5 7.2 4.6 6 0.6 7.2 4.6 29 6 30 305 -8.8 0 -8.8 -9 03/02/2006 15:30:00 5.3 0.7 6.8 3.8 4.9 0.7 6.5 3 29 8 33 305 -8.8 0 -8.6 -9 03/02/2006 15:40:00 6 0.9 8 4.2 5.7 1 8 3.8 32 6 32 305 -8.7 0 -8.4 -8.8 03/02/2006 15:50:00 6.1 0.7 7.6 4.6 6 0.7 8 4.2 39 6 35 305 -8.5 0 -8.2 -8.8 03/02/2006 16:00:00 6.7 0.6 8.4 5.3 6.7 0.6 8 4.9 40 6 41 305 -8.6 0.1 -8.4 -8.8 03/02/2006 16:10:00 6.3 0.7 8 4.6 6.2 0.7 8 4.6 47 6 44 305 -8.6 0 -8.4 -8.8 03/02/2006 16:20:00 7.2 0.9 9.1 5.3 7 1 9.1 4.6 59 6 62 305 -8.8 0 -8.4 -9.2 03/02/2006 16:30:00 8.2 0.6 9.9 6.5 8 0.6 9.1 6.5 65 5 68 305 -9 0 -8.8 -9.2 03/02/2006 16:40:00 7.8 0.8 9.1 5.7 7.6 0.8 8.8 5.3 57 5 64 305 -9 0 -8.8 -9.2 03/02/2006 16:50:00 7.3 0.9 8.8 4.9 7.2 1 8.8 4.6 53 4 58 305 -9 0 -8.8 -9.2 03/02/2006 17:00:00 7.7 0.7 9.1 5.3 7.6 0.9 9.1 4.9 54 4 53 305 -9.1 0.1 -8.8 -9.4 03/02/2006 17:10:00 7.8 0.5 9.1 5.7 7.6 0.7 9.1 5.3 55 5 47 305 -9.3 0 -9 -9.4 03/02/2006 17:20:00 7.3 0.7 8.8 5.7 7.2 0.8 8.8 5.3 52 5 57 305 -9.4 0 -9.2 -9.6 03/02/2006 17:30:00 8.2 0.6 9.5 6.5 8.1 0.7 9.5 6.1 56 4 56 305 -9.4 0 -9.2 -9.6 03/02/2006 17:40:00 8.5 0.6 9.5 6.8 8.4 0.7 9.5 6.1 55 3 54 305 -9.4 0 -9.2 -9.6 03/02/2006 17:50:00 7.8 0.6 9.1 5.3 7.6 0.7 9.1 5.7 57 4 61 305 -9.3 0 -9 -9.4 03/02/2006 18:00:00 7.5 0.6 9.1 6.1 7.3 0.7 8.8 5.7 53 5 59 305 -9.2 0 -8.8 -9.2 03/02/2006 18:10:00 7.7 0.8 9.1 5.3 7.6 1 9.5 4.9 50 5 50 305 -9.3 0 -9 -9.6 03/02/2006 18:20:00 7.5 0.8 9.5 5.7 7.4 0.9 9.5 4.9 49 5 51 305 -9.4 0 -9.2 -9.6 03/02/2006 18:30:00 8 0.7 9.1 6.5 7.8 0.8 9.5 5.7 51 5 37 305 -9.6 0 -9.2 -9.6 03/02/2006 18:40:00 8.4 0.6 9.5 6.1 8.4 0.6 9.5 5.7 50 3 48 305 -9.7 0.1 -9.4 -9.8 03/02/2006 18:50:00 8 0.6 9.1 6.8 7.9 0.7 9.5 5.7 48 4 48 305 -9.7 0 -9.4 -9.8 03/02/2006 19:00:00 8.3 0.7 9.5 6.1 8.2 0.8 9.9 6.1 46 3 45 305 -9.8 0 -9.6 -9.8 03/02/2006 19:10:00 8.5 0.6 9.9 6.5 8.4 0.8 10.3 6.1 44 3 42 305 -9.8 0 -9.6 -10 03/02/2006 19:20:00 6.7 0.8 8.8 4.9 6.4 0.8 8.4 4.6 40 5 39 305 -9.8 0 -9.6 -10 03/02/2006 19:30:00 4.9 0.5 6.5 3.8 4.6 0.6 6.1 3.4 36 7 30 305 -9.8 0 -9.6 -10 03/02/2006 19:40:00 5.5 0.8 7.2 3 5.3 0.9 6.8 2.6 39 5 45 305 -9.8 0 -9.6 -10 03/02/2006 19:50:00 5.9 0.6 7.2 3.8 5.7 0.7 6.8 4.2 37 4 39 305 -9.8 0 -9.6 -9.8 03/02/2006 20:00:00 6.1 0.4 7.2 5.3 5.9 0.4 7.2 4.9 40 4 35 305 -9.8 0 -9.6 -10 03/02/2006 20:10:00 6.4 0.5 7.6 4.9 6.2 0.6 7.2 4.6 39 4 39 305 -9.9 0 -9.6 -10 03/02/2006 20:20:00 6.2 0.6 7.6 4.2 6.1 0.7 7.6 4.2 40 4 39 305 -10 0 -9.8 -10.2 03/02/2006 20:30:00 6.5 0.7 7.6 4.6 6.3 0.8 7.6 3.8 40 5 32 305 -10.1 0 -9.8 -10.2 03/02/2006 20:40:00 6.9 0.7 8 4.9 6.8 0.7 8 4.9 41 4 42 305 -10.1 0 -9.8 -10.2 03/02/2006 20:50:00 6.6 0.5 7.6 5.3 6.5 0.5 7.6 5.3 44 5 39 305 -10.1 0 -9.8 -10.2 03/02/2006 21:00:00 6.1 0.6 7.2 4.6 6 0.7 7.2 4.2 40 5 39 305 -10 0 -9.8 -10 03/02/2006 21:10:00 5.7 0.5 6.8 4.6 5.5 0.5 6.5 3.8 43 6 45 305 -10 0 -9.8 -10.2 03/02/2006 21:20:00 5.8 0.5 7.2 4.2 5.7 0.6 7.2 4.2 35 5 32 305 -10.1 0 -9.8 -10.2 03/02/2006 21:30:00 5.6 0.5 6.8 4.2 5.5 0.7 7.2 3.8 40 6 47 305 -10.3 0 -10 -10.4 03/02/2006 21:40:00 6 0.7 7.6 4.2 5.8 0.6 8 4.2 40 6 35 305 -10.4 0 -10 -10.4 03/02/2006 21:50:00 6.9 0.6 8.4 4.9 6.8 0.6 8.4 4.9 34 4 35 305 -10.5 0 -10.2 -10.9 03/02/2006 22:00:00 6.7 0.5 8 5.3 6.7 0.6 8 5.3 38 5 44 305 -10.8 0.1 -10.4 -10.9 03/02/2006 22:10:00 6.7 0.5 8 5.7 6.6 0.5 8 5.3 37 5 30 305 -10.8 0 -10.4 -10.9 03/02/2006 22:20:00 7.1 0.6 8.4 5.3 7 0.6 8.8 5.3 42 5 42 305 -10.8 0 -10.4 -10.9 03/02/2006 22:30:00 7 0.5 8 5.7 6.9 0.6 8 4.9 41 4 37 305 -10.8 0 -10.4 -10.9 03/02/2006 22:40:00 6.5 0.6 8.4 4.9 6.3 0.6 8 4.6 44 5 39 305 -10.8 0 -10.4 -10.9 03/02/2006 22:50:00 6.9 0.5 8.4 5.3 6.8 0.6 8.4 5.3 45 5 41 305 -10.8 0 -10.7 -10.9 03/02/2006 23:00:00 7.1 0.6 8.4 5.3 7 0.8 8.4 4.6 45 5 41 305 -10.9 0 -10.7 -11.3 03/02/2006 23:10:00 7.3 0.5 8.4 5.7 7.2 0.6 8.8 5.7 44 4 37 305 -11.2 0 -10.9 -11.3 03/02/2006 23:20:00 6.5 0.6 8 4.9 6.4 0.7 8 4.6 43 5 42 305 -11.3 0 -11.1 -11.5 03/02/2006 23:30:00 5.8 0.6 7.2 3.8 5.5 0.7 7.2 3.8 41 8 38 305 -11.3 0 -11.1 -11.5 03/02/2006 23:40:00 6.4 0.6 7.6 4.6 6.2 0.6 7.6 4.9 32 4 32 305 -11.4 0 -11.3 -11.5 03/02/2006 23:50:00 6.8 0.4 7.6 5.3 6.7 0.5 7.6 4.9 33 4 31 305 -11.4 0 -11.3 -11.5 03/03/2006 00:00:00 6.3 0.5 7.6 5.3 6.2 0.5 7.6 4.6 34 5 30 305 -11.4 0 -11.1 -11.5 03/03/2006 00:10:00 6.4 0.6 8 4.9 6.3 0.6 8 4.9 34 5 38 305 -11.4 0 -11.3 -11.5 03/03/2006 00:20:00 7.3 0.4 8.4 5.7 7.2 0.5 8.4 5.7 33 3 36 305 -11.5 0 -11.3 -11.7 03/03/2006 00:30:00 6.8 0.7 8.4 5.3 6.7 0.8 8.4 4.9 36 4 33 305 -11.5 0 -11.3 -11.7 03/03/2006 00:40:00 6.8 0.6 8 5.3 6.7 0.6 8 5.3 34 4 30 305 -11.5 0 -11.3 -11.7 03/03/2006 00:50:00 7.1 0.3 8 5.7 7 0.4 8 5.7 40 3 36 305 -11.5 0 -11.3 -11.7 03/03/2006 01:00:00 6.5 0.4 7.6 5.3 6.4 0.5 7.6 4.9 40 3 41 305 -11.5 0 -11.3 -11.7 03/03/2006 01:10:00 6.3 0.3 6.8 5.3 6.2 0.4 7.2 4.9 39 3 42 305 -11.5 0 -11.3 -11.7 03/03/2006 01:20:00 6.3 0.4 6.8 4.9 6.2 0.4 6.8 4.9 39 4 37 305 -11.5 0 -11.3 -11.7 03/03/2006 01:30:00 5.6 0.4 6.5 4.6 5.6 0.5 6.5 4.2 41 5 30 305 -11.4 0 -11.3 -11.7 03/03/2006 01:40:00 5.4 0.6 6.5 3.8 5.2 0.7 6.5 3.4 39 5 41 305 -11.4 0 -11.3 -11.5 03/03/2006 01:50:00 5.4 0.5 6.5 3.8 5.1 0.5 6.1 3.8 26 5 25 305 -11.4 0 -11.3 -11.5 03/03/2006 02:00:00 5.4 0.3 6.1 4.2 5.2 0.4 6.1 4.2 24 5 32 305 -11.6 0 -11.5 -11.9 03/03/2006 02:10:00 5.2 0.3 5.7 4.2 5 0.4 6.1 3.8 21 4 25 305 -11.7 0 -11.5 -11.9 03/03/2006 02:20:00 5.2 0.3 5.7 3.8 4.9 0.3 5.7 3.8 23 3 21 305 -11.8 0 -11.7 -12.1 03/03/2006 02:30:00 5.4 0.3 6.1 4.6 5.1 0.4 5.7 4.2 22 3 25 305 -11.8 0 -11.7 -12.1 03/03/2006 02:40:00 4.7 0.4 5.7 3.8 4.5 0.4 5.3 3.4 23 3 24 305 -11.8 0 -11.7 -12.1 03/03/2006 02:50:00 4.7 0.4 5.7 3.8 4.4 0.5 5.3 3.4 25 3 25 305 -11.8 0 -11.7 -12.1 03/03/2006 03:00:00 4.8 0.4 5.7 3.8 4.5 0.4 5.3 3.8 27 3 24 305 -11.8 0 -11.5 -12.1 03/03/2006 03:10:00 5 0.2 5.7 4.6 4.8 0.3 5.7 4.2 26 2 28 305 -11.8 0 -11.5 -11.9 03/03/2006 03:20:00 4.8 0.3 5.3 4.2 4.4 0.4 5.3 3.4 29 3 30 305 -11.8 0 -11.5 -11.9 03/03/2006 03:30:00 5.1 0.3 5.7 4.6 4.8 0.4 5.7 3.8 27 3 30 305 -11.9 0 -11.7 -12.1 03/03/2006 03:40:00 4.8 0.3 5.3 4.2 4.5 0.3 5.3 3.4 25 3 25 305 -12 0 -11.7 -12.1 03/03/2006 03:50:00 4.6 0.3 5.3 3.4 4.3 0.3 4.9 3.8 25 3 27 305 -12 0 -11.7 -12.1 03/03/2006 04:00:00 4.6 0.3 5.3 3.4 4.3 0.3 4.9 3 27 3 32 305 -12 0 -11.7 -12.1 03/03/2006 04:10:00 4.5 0.4 5.3 3.8 4.2 0.4 4.9 3 30 4 33 305 -12 0 -11.7 -12.1 03/03/2006 04:20:00 4.7 0.2 5.3 4.2 4.5 0.3 5.3 3.4 26 3 28 305 -12 0 -11.7 -12.1 03/03/2006 04:30:00 4.6 0.2 5.3 3.8 4.4 0.3 4.9 3.4 24 2 24 305 -12.2 0 -12.1 -12.5 03/03/2006 04:40:00 4.5 0.2 4.9 3.8 4.2 0.3 4.9 3.4 23 2 25 305 -12.5 0.1 -12.1 -12.7 03/03/2006 04:50:00 4.2 0.3 4.9 3.4 4 0.3 4.9 3 29 4 27 305 -12.7 0 -12.5 -12.9 03/03/2006 05:00:00 4.2 0.3 4.9 3.4 3.9 0.3 4.6 3 22 3 19 305 -13.2 0.2 -12.7 -13.5 03/03/2006 05:10:00 4.2 0.3 4.9 3.4 3.9 0.3 4.6 3 23 4 18 305 -13.3 0.2 -12.9 -13.5 03/03/2006 05:20:00 4.4 0.3 4.9 3.8 4.1 0.2 4.6 3.4 25 2 28 305 -12.6 0 -12.5 -12.9 03/03/2006 05:30:00 3.9 0.3 4.6 3 3.6 0.3 4.2 2.6 27 4 25 305 -12.6 0 -12.5 -12.7 03/03/2006 05:40:00 3.5 0.3 4.2 2.6 3.2 0.4 3.8 1.9 32 4 33 305 -12.6 0 -12.3 -12.7 03/03/2006 05:50:00 3 0.4 4.2 2.3 2.7 0.4 3.8 1.9 17 7 26 305 -12.5 0 -12.3 -12.5 03/03/2006 06:00:00 3 0.4 3.8 1.9 2.7 0.5 3.8 1.5 16 5 11 305 -12.5 0 -12.3 -12.7 03/03/2006 06:10:00 3.3 0.3 4.2 2.6 3.2 0.4 3.8 2.3 10 0 10 305 -12.6 0 -12.5 -12.9 03/03/2006 06:20:00 3.6 0.2 4.2 3 3.4 0.3 4.2 2.6 14 5 10 305 -12.7 0 -12.5 -12.9 03/03/2006 06:30:00 3.5 0.3 4.2 2.6 3.3 0.4 4.2 2.3 18 4 10 305 -12.6 0 -12.5 -12.7 03/03/2006 06:40:00 3.3 0.3 4.2 2.6 3.2 0.4 4.2 2.3 12 4 10 305 -12.6 0 -12.5 -12.9 03/03/2006 06:50:00 3.6 0.2 4.2 3 3.4 0.3 3.8 2.6 16 3 7 305 -12.8 0 -12.5 -12.9 03/03/2006 07:00:00 3.4 0.3 4.2 2.6 3.2 0.3 4.2 2.3 18 5 14 305 -12.8 0 -12.5 -12.9 03/03/2006 07:10:00 3.5 0.2 4.2 3 3.3 0.2 3.8 2.6 19 3 21 305 -12.8 0 -12.5 -12.9 03/03/2006 07:20:00 3.3 0.3 4.2 2.6 3.2 0.3 3.8 2.3 25 5 27 305 -12.9 0.1 -12.5 -13.1 03/03/2006 07:30:00 3.4 0.2 4.2 3 3.2 0.3 3.8 2.3 22 4 15 305 -12.9 0.1 -12.7 -13.1 03/03/2006 07:40:00 3.6 0.3 4.2 3 3.4 0.3 4.2 2.6 20 4 14 305 -13.2 0.1 -12.9 -13.5 03/03/2006 07:50:00 3.7 0.2 4.2 3 3.5 0.3 4.2 2.6 19 2 19 305 -13.4 0.1 -13.1 -13.7 03/03/2006 08:00:00 3.1 0.3 3.8 2.3 2.8 0.3 3.4 2.3 24 3 25 305 -13.5 0.1 -13.3 -13.7 03/03/2006 08:10:00 2.8 0.3 3.4 2.3 2.5 0.4 3.4 1.9 25 2 25 305 -13.7 0 -13.3 -14.1 03/03/2006 08:20:00 3 0.2 3.4 2.6 2.7 0.3 3.4 1.9 26 3 23 305 -13.6 0 -13.3 -13.7 03/03/2006 08:30:00 3.1 0.2 3.8 2.6 3 0.2 3.4 2.6 27 2 27 305 -13.2 0.1 -13.1 -13.7 03/03/2006 08:40:00 2.7 0.4 3.4 1.9 2.4 0.4 3.4 1.5 34 7 24 305 -13.1 0 -12.9 -13.3 03/03/2006 08:50:00 2.4 0.2 3 1.9 2.3 0.2 3 1.5 30 9 27 305 -13 0 -12.9 -13.1 03/03/2006 09:00:00 2.5 0.9 3.8 0.4 2.6 1.1 4.2 0.4 108 86 184 305 -13.2 0.2 -12.7 -13.7 03/03/2006 09:10:00 2.7 0.5 3.8 1.5 2.8 0.6 3.8 1.5 199 10 189 305 -13.7 0 -13.3 -14.1 03/03/2006 09:20:00 2 0.5 3 1.1 2 0.4 3 1.1 209 6 217 305 -13.5 0.1 -13.1 -13.7 03/03/2006 09:30:00 2.1 0.5 3 1.1 2 0.5 3 0.7 207 7 206 305 -13.2 0 -12.9 -13.5 03/03/2006 09:40:00 2.4 0.6 4.2 1.5 2.1 0.7 3.8 0.7 212 9 210 305 -13.1 0 -12.9 -13.3 03/03/2006 09:50:00 2.3 0.5 3.8 1.1 2 0.6 3.8 0.7 208 9 208 305 -13 0.1 -12.7 -13.3 03/03/2006 10:00:00 2.2 0.6 3.4 0.7 2 0.6 3.8 0.4 198 12 201 305 -12.8 0 -12.5 -12.9 03/03/2006 10:10:00 2 0.8 3.8 0.4 1.7 0.9 3.8 0.4 211 12 201 305 -12.7 0 -12.5 -12.9 03/03/2006 10:20:00 2.3 0.5 3.4 0.7 2.1 0.6 3.4 0.4 200 9 192 305 -12.6 0 -12.3 -12.7 03/03/2006 10:30:00 2.4 0.3 3.4 1.5 1.8 0.5 3 0.7 239 16 253 305 -12.5 0.1 -12.1 -12.5 03/03/2006 10:40:00 2.1 0.5 3 0.7 1.3 0.5 2.3 0.4 251 8 245 305 -12.3 0 -12.1 -12.5 03/03/2006 10:50:00 1 0.6 2.6 0.4 0.5 0.3 1.5 0.4 263 0 262 305 -12.1 0 -11.7 -12.3 03/03/2006 11:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 263 0 262 305 -11.8 0.1 -11.5 -12.1 03/03/2006 11:10:00 0.7 0.3 1.1 0.4 0.6 0.2 1.1 0.4 263 0 262 305 -11.8 0.1 -11.5 -12.1 03/03/2006 11:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 263 0 262 305 -11.7 0 -11.3 -11.9 03/03/2006 11:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 263 0 263 305 -11.4 0.1 -10.9 -11.7 03/03/2006 11:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 263 0 263 305 -11.2 0.1 -10.9 -11.5 03/03/2006 11:50:00 0.6 0.5 1.9 0.4 0.6 0.3 1.5 0.4 332 94 262 305 -11.2 0 -10.9 -11.5 03/03/2006 12:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 105 0 105 305 -10.9 0.1 -10.4 -11.3 03/03/2006 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 9 305 305 -10.5 0.1 -10 -10.9 03/03/2006 12:20:00 1.3 0.5 2.3 0.4 1.3 0.6 2.6 0.4 156 22 181 305 -10.9 0.3 -10.2 -11.5 03/03/2006 12:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 131 0 131 305 -10.5 0.3 -9.8 -11.3 03/03/2006 12:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 131 0 131 305 -10.4 0.1 -9.8 -10.9 03/03/2006 12:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 131 0 131 305 -10.1 0.3 -9.2 -10.4 03/03/2006 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 131 0 305 305 -9.3 0.1 -8.8 -9.6 03/03/2006 13:10:00 1 0.6 2.3 0.4 0.7 0.5 1.9 0.4 133 24 140 305 -9.8 0.3 -9 -10.2 03/03/2006 13:20:00 2.7 0.9 4.2 0.4 2.5 1 3.8 0.4 101 15 102 305 -10.2 0.3 -9.4 -10.9 03/03/2006 13:30:00 2.2 0.7 3.8 0.7 1.8 0.9 3.4 0.4 100 17 110 305 -10.7 0.1 -10.4 -10.9 03/03/2006 13:40:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 30 24 46 305 -10.7 0.2 -10.2 -10.9 03/03/2006 13:50:00 1 0.7 3 0.4 0.8 0.7 2.6 0.4 58 49 114 305 -10.5 0.3 -9.8 -11.1 03/03/2006 14:00:00 1.2 0.5 2.6 0.4 0.8 0.5 1.9 0.4 73 10 93 305 -10.4 0 -9.8 -10.7 03/03/2006 14:10:00 1.7 0.7 3.4 0.4 1.3 0.7 3 0.4 70 20 88 305 -10.4 0 -10 -10.9 03/03/2006 14:20:00 1.1 0.7 3 0.4 0.9 0.6 2.6 0.4 60 36 87 305 -10.6 0 -10.2 -10.9 03/03/2006 14:30:00 1.1 0.8 3.4 0.4 0.9 0.7 3 0.4 90 30 109 305 -9.8 0.3 -9.2 -10.7 03/03/2006 14:40:00 2.3 0.5 3.8 1.1 2.1 0.5 3.4 0.7 81 15 97 305 -9.9 0.2 -9.2 -10.4 03/03/2006 14:50:00 1.6 0.7 3.8 0.4 1.3 0.7 3.4 0.4 52 10 56 305 -10.7 0.1 -10.2 -10.9 03/03/2006 15:00:00 3.6 0.7 5.3 1.9 3.6 1 6.5 1.5 68 11 56 305 -11 0.3 -10.4 -11.5 03/03/2006 15:10:00 5.2 0.6 6.8 3.4 5.5 0.5 6.8 4.2 58 5 72 305 -11.5 0 -11.5 -11.7 03/03/2006 15:20:00 5.6 0.6 7.2 3 5.9 0.7 7.6 3 51 5 63 305 -11.6 0 -11.5 -11.9 03/03/2006 15:30:00 5 0.5 6.8 3.4 5.1 0.5 7.2 3.8 37 13 29 305 -11.7 0 -11.5 -11.9 03/03/2006 15:40:00 5.2 0.4 6.5 4.2 5.2 0.4 6.5 4.2 15 3 12 305 -11.8 0 -11.5 -12.1 03/03/2006 15:50:00 4.7 0.7 7.2 3 4.8 0.6 7.2 3 26 11 55 305 -11.8 0 -11.5 -11.9 03/03/2006 16:00:00 4.2 1 6.8 1.5 3.9 0.9 5.7 1.1 56 28 23 305 -11.7 0 -11.5 -11.9 03/03/2006 16:10:00 6 0.8 7.6 4.2 5.3 0.8 6.8 3.4 89 5 91 305 -11.4 0 -11.1 -11.7 03/03/2006 16:20:00 6.9 0.6 8.4 5.3 6.2 0.5 7.6 4.6 89 5 93 305 -11.3 0.1 -10.9 -11.5 03/03/2006 16:30:00 6.8 0.8 8.8 5.3 6.1 0.8 8 4.6 89 7 93 305 -11.2 0 -10.9 -11.5 03/03/2006 16:40:00 7.7 0.9 9.9 5.3 7.2 0.9 9.5 4.6 93 9 93 305 -11 0 -10.7 -11.3 03/03/2006 16:50:00 8.8 0.8 10.7 6.1 8.1 0.8 10.3 5.3 94 8 82 305 -11.1 0 -10.9 -11.3 03/03/2006 17:00:00 9.2 0.5 10.7 7.2 8.4 0.5 9.9 6.8 90 6 89 305 -11.2 0.1 -10.9 -11.5 03/03/2006 17:10:00 8.7 0.5 10.7 7.6 8.1 0.5 9.5 6.8 80 5 84 305 -11.4 0 -11.1 -11.5 03/03/2006 17:20:00 7.9 0.3 8.8 6.8 7.5 0.3 8.4 6.5 68 3 71 305 -11.5 0 -11.3 -11.5 03/03/2006 17:30:00 8.1 0.5 9.1 6.5 7.7 0.5 8.8 6.5 67 3 69 305 -11.4 0 -11.1 -11.5 03/03/2006 17:40:00 8 0.5 9.1 6.8 7.5 0.6 8.8 6.1 69 4 68 305 -11.2 0 -10.9 -11.5 03/03/2006 17:50:00 8.6 0.6 10.3 6.8 8 0.6 9.9 6.1 75 5 81 305 -11 0 -10.9 -11.3 03/03/2006 18:00:00 9.4 0.8 12.2 7.6 8.8 0.7 11.1 7.2 76 6 80 305 -11 0 -10.9 -11.3 03/03/2006 18:10:00 10.3 1 12.6 6.8 9.5 1 11.8 6.8 80 6 75 305 -11 0 -10.9 -11.3 03/03/2006 18:20:00 10.3 0.9 12.6 8 9.4 0.9 11.8 6.8 83 7 84 305 -10.9 0 -10.7 -11.1 03/03/2006 18:30:00 10.9 1 14.5 7.6 10 1 14.1 7.6 83 6 90 305 -10.9 0 -10.7 -10.9 03/03/2006 18:40:00 11.8 0.8 14.1 9.5 10.9 0.9 13.3 8.8 82 6 82 305 -10.9 0 -10.4 -11.1 03/03/2006 18:50:00 12.5 0.6 14.9 11.1 11.6 0.6 13.7 9.5 81 4 82 305 -10.9 0 -10.7 -11.1 03/03/2006 19:00:00 12.6 0.7 14.5 9.9 11.6 0.7 13.7 9.5 82 5 81 305 -11 0 -10.7 -11.3 03/03/2006 19:10:00 11.8 0.7 14.1 9.9 11 0.7 13.3 9.5 82 5 77 305 -11.1 0 -10.9 -11.3 03/03/2006 19:20:00 12.1 0.5 13.7 11.1 11.2 0.5 12.6 9.5 81 3 83 305 -11.2 0 -10.9 -11.3 03/03/2006 19:30:00 11.9 0.4 13 10.7 11.1 0.4 12.2 9.9 80 3 80 305 -11.4 0 -10.9 -11.7 03/03/2006 19:40:00 11.5 0.4 12.6 10.3 10.7 0.5 11.8 9.1 76 3 77 305 -11.6 0 -11.3 -11.9 03/03/2006 19:50:00 10.9 0.4 11.8 9.9 10.4 0.4 11.5 9.1 69 3 68 305 -11.8 0 -11.5 -12.1 03/03/2006 20:00:00 9.9 0.5 11.1 8.4 9.7 0.5 11.1 7.6 64 3 66 305 -11.8 0 -11.7 -12.1 03/03/2006 20:10:00 9.3 0.5 10.7 7.6 9.1 0.6 10.3 7.2 62 4 61 305 -11.8 0 -11.7 -11.9 03/03/2006 20:20:00 9.1 0.5 9.9 8 9 0.5 9.9 7.6 60 3 59 305 -11.7 0 -11.5 -11.9 03/03/2006 20:30:00 8.8 0.5 9.9 7.6 8.7 0.6 10.3 7.2 58 3 58 305 -11.5 0 -11.3 -11.7 03/03/2006 20:40:00 8.3 0.5 9.1 6.8 8.3 0.5 9.1 6.8 50 4 56 305 -11.5 0 -11.3 -11.7 03/03/2006 20:50:00 7.9 0.4 8.8 6.5 8 0.4 8.8 6.5 46 3 44 305 -11.4 0 -11.3 -11.5 03/03/2006 21:00:00 7.8 0.5 9.1 6.5 7.7 0.5 9.1 6.1 47 4 51 305 -11.4 0.1 -10.9 -11.5 03/03/2006 21:10:00 7.3 0.6 8.4 6.1 7.2 0.6 8.8 5.7 44 5 52 305 -11.2 0.1 -10.9 -11.5 03/03/2006 21:20:00 6 0.8 8.4 4.2 5.9 0.7 7.6 4.6 41 7 55 305 -10.9 0.1 -10.4 -11.3 03/03/2006 21:30:00 7.7 0.8 9.5 6.1 7.5 0.7 9.1 5.7 46 6 48 305 -10.8 0.1 -10.4 -10.9 03/03/2006 21:40:00 8.4 0.7 9.9 6.8 8.1 0.7 9.9 6.5 51 5 48 305 -10.7 0 -10.4 -10.9 03/03/2006 21:50:00 8.2 0.7 9.9 6.5 8 0.7 10.3 6.5 49 4 46 305 -10.5 0 -10.2 -10.9 03/03/2006 22:00:00 7.1 0.5 8.4 5.7 7 0.6 8.4 5.7 46 4 51 305 -10.4 0 -10 -10.7 03/03/2006 22:10:00 7.3 0.8 9.5 4.9 7.2 0.8 9.1 4.9 51 6 58 305 -9.9 0.3 -9.2 -10.4 03/03/2006 22:20:00 8.4 1.1 11.8 5.7 8 1 11.1 5.7 61 6 62 305 -9.2 0.1 -8.8 -9.4 03/03/2006 22:30:00 8.6 0.8 11.5 6.5 8.1 0.8 10.3 5.7 62 7 67 305 -9 0 -8.6 -9.2 03/03/2006 22:40:00 9.9 1.1 13.3 6.8 9.4 1.1 12.6 6.5 69 7 70 305 -8.9 0 -8.4 -9.2 03/03/2006 22:50:00 10.8 0.8 13 8.8 10.4 0.9 12.2 8 69 6 80 305 -9.1 0.1 -8.6 -9.2 03/03/2006 23:00:00 11 1.2 14.1 7.6 10.4 1.3 13.7 7.6 71 7 77 305 -9.3 0 -8.8 -9.6 03/03/2006 23:10:00 11.8 1.2 15.6 8.4 11.2 1.2 15.6 7.6 72 7 72 305 -9.4 0 -9.2 -9.6 03/03/2006 23:20:00 12.1 1 15.3 9.5 11.5 1.2 14.9 8.8 73 6 74 305 -9.6 0 -9.2 -9.6 03/03/2006 23:30:00 12.4 1.1 15.6 9.5 11.7 1.2 14.5 8 75 6 72 305 -9.7 0.1 -9.2 -9.8 03/03/2006 23:40:00 12.6 0.9 14.9 9.1 12.2 1 14.5 8.4 70 5 75 305 -10 0.2 -9.6 -10.4 03/03/2006 23:50:00 11.8 0.8 14.1 9.5 11.5 1 13.7 8.4 66 5 70 305 -10.4 0 -10 -10.7 03/04/2006 00:00:00 11.5 1.5 15.6 8 10.8 1.6 14.9 6.8 77 6 72 305 -10.5 0 -10.2 -10.9 03/04/2006 00:10:00 12.3 1 14.5 8.8 11.5 1.1 14.5 8.8 77 6 80 305 -10.8 0.1 -10.4 -10.9 03/04/2006 00:20:00 12 1.1 15.6 9.1 11.5 1.1 14.9 8 75 6 75 305 -10.9 0 -10.4 -11.1 03/04/2006 00:30:00 11.5 1 14.1 9.5 11.1 1 14.1 9.1 69 5 70 305 -11 0 -10.7 -11.3 03/04/2006 00:40:00 11.3 0.8 13 9.5 10.9 1 13.3 8.4 68 5 75 305 -11 0 -10.7 -11.1 03/04/2006 00:50:00 12 0.9 14.5 9.5 11.8 1 14.1 9.1 69 5 77 305 -10.9 0 -10.7 -11.1 03/04/2006 01:00:00 12.3 0.9 14.9 10.3 11.8 1 14.5 9.5 72 6 78 305 -10.9 0 -10.4 -10.9 03/04/2006 01:10:00 12.2 1.1 15.3 9.1 11.6 1.2 13.7 8.4 72 6 73 305 -10.8 0.1 -10.4 -10.9 03/04/2006 01:20:00 12.6 1 15.6 10.3 12 1 15.3 9.1 73 6 85 305 -10.8 0.1 -10.4 -10.9 03/04/2006 01:30:00 13 1 16.4 10.3 12.6 1.1 16.1 9.1 69 5 80 305 -10.7 0 -10.4 -10.9 03/04/2006 01:40:00 12.2 1.1 15.3 9.1 11.9 1.2 14.9 9.1 65 5 66 305 -10.6 0 -10.4 -10.9 03/04/2006 01:50:00 11.2 1.3 14.9 8.8 10.8 1.3 14.5 8 64 6 65 305 -10.4 0 -10 -10.9 03/04/2006 02:00:00 11.5 1 14.1 8.8 11.2 1.1 13.7 8.8 61 6 64 305 -10.3 0.1 -9.8 -10.4 03/04/2006 02:10:00 12.3 1.2 14.9 9.1 11.9 1.2 14.9 8.8 63 5 67 305 -10.2 0.1 -9.8 -10.4 03/04/2006 02:20:00 13.1 1.3 16.4 9.5 12.6 1.4 16.4 8.8 65 6 68 305 -9.9 0 -9.4 -10.2 03/04/2006 02:30:00 11.4 0.7 13 9.5 11.1 0.8 13 8.8 60 6 62 305 -10 0.2 -9.4 -10.4 03/04/2006 02:40:00 11.3 1 13.7 8.8 11.1 1.1 13.3 8.4 60 5 62 305 -10.1 0.1 -9.6 -10.4 03/04/2006 02:50:00 10.2 0.9 12.2 7.6 9.9 0.9 12.2 7.2 60 5 61 305 -9.8 0 -9.4 -10 03/04/2006 03:00:00 11.2 1.1 14.5 8.4 10.8 1.2 14.1 8.4 63 6 76 305 -9.5 0.2 -8.8 -9.8 03/04/2006 03:10:00 12.8 1.1 15.3 9.9 12.3 1.1 14.9 8.8 66 5 68 305 -9 0 -8.8 -9.2 03/04/2006 03:20:00 12.2 1.1 14.9 9.1 11.9 1.1 14.9 8.4 65 5 69 305 -9 0 -8.6 -9.2 03/04/2006 03:30:00 11.4 1.1 14.1 8.8 11.2 1.1 13.7 8 63 5 62 305 -8.8 0 -8.4 -9 03/04/2006 03:40:00 13 1.3 16.8 9.1 12.8 1.3 16.4 9.1 66 6 67 305 -8.6 0.1 -8.2 -8.8 03/04/2006 03:50:00 13.3 1.3 16.8 10.3 12.9 1.3 16.8 9.9 67 5 67 305 -8.4 0 -7.9 -8.6 03/04/2006 04:00:00 13.9 1.3 17.2 10.7 13.5 1.3 17.2 9.5 68 5 73 305 -8.3 0 -7.9 -8.4 03/04/2006 04:10:00 13.2 1.2 16.4 10.3 12.8 1.2 16.1 10.3 66 5 71 305 -8.2 0.1 -7.7 -8.4 03/04/2006 04:20:00 12.9 1.4 16.1 9.1 12.6 1.5 16.4 8 64 5 66 305 -7.9 0 -7.3 -8.2 03/04/2006 04:30:00 12.6 1.1 15.6 9.5 12.3 1.2 15.6 9.5 63 5 67 305 -7.7 0.1 -7.3 -7.9 03/04/2006 04:40:00 13.2 1.3 16.1 10.3 12.9 1.3 15.6 9.5 62 5 72 305 -7.5 0.1 -7.1 -7.7 03/04/2006 04:50:00 12.9 1.2 16.1 9.9 12.4 1.2 16.1 9.1 65 5 76 305 -7.4 0 -6.9 -7.5 03/04/2006 05:00:00 13.9 1.3 17.2 10.7 13.5 1.5 17.2 9.9 65 6 63 305 -7.4 0 -6.9 -7.5 03/04/2006 05:10:00 14 1.7 17.9 9.5 13.8 1.7 17.6 9.1 64 5 62 305 -7.3 0 -6.9 -7.5 03/04/2006 05:20:00 14.2 1.4 17.9 10.7 13.8 1.5 18.3 9.9 63 6 65 305 -7.1 0 -6.9 -7.3 03/04/2006 05:30:00 13.8 1.4 17.2 10.7 13.4 1.5 17.2 9.9 64 6 66 305 -7.1 0 -6.7 -7.3 03/04/2006 05:40:00 14.9 1.5 18.7 10.7 14.6 1.7 19.1 11.5 64 6 71 305 -7.1 0 -6.7 -7.3 03/04/2006 05:50:00 15 1.4 18.3 11.8 14.7 1.5 18.3 11.1 64 6 65 305 -7.1 0 -6.7 -7.3 03/04/2006 06:00:00 14.9 1.5 18.3 11.5 14.4 1.5 17.9 10.3 62 6 60 305 -7.1 0 -6.7 -7.3 03/04/2006 06:10:00 15.5 1.4 20.2 12.2 15.1 1.5 19.5 11.1 64 6 64 305 -7.1 0 -6.7 -7.3 03/04/2006 06:20:00 15.7 1.6 19.5 11.8 15.4 1.7 19.5 10.7 63 5 68 305 -7.1 0 -6.7 -7.3 03/04/2006 06:30:00 15.9 1.7 20.2 10.7 15.5 1.7 19.5 10.3 63 5 70 305 -7.1 0 -6.7 -7.3 03/04/2006 06:40:00 15.8 1.5 19.9 11.8 15.4 1.5 19.5 11.8 64 6 63 305 -7.1 0 -6.9 -7.3 03/04/2006 06:50:00 16.5 1.6 19.9 13 16.1 1.7 19.5 11.1 64 5 62 305 -7.1 0 -6.9 -7.3 03/04/2006 07:00:00 16.9 1.6 21 13 16.6 1.7 22.1 11.8 63 6 60 305 -7.1 0 -6.9 -7.3 03/04/2006 07:10:00 17.2 1.7 21 13.3 16.8 1.7 21.4 12.6 65 6 70 305 -7.1 0 -6.9 -7.3 03/04/2006 07:20:00 17.3 1.7 23.3 13 17 1.8 22.9 12.2 66 6 70 305 -7.1 0 -6.9 -7.3 03/04/2006 07:30:00 18.2 1.7 23.3 14.1 17.9 1.7 22.9 13.7 68 6 70 305 -7.1 0 -6.9 -7.1 03/04/2006 07:40:00 19 1.5 22.1 15.3 18.6 1.6 22.6 14.5 68 5 72 305 -7.1 0 -6.9 -7.1 03/04/2006 07:50:00 18.8 1.7 22.1 14.1 18.5 1.9 22.1 13 67 5 69 305 -7.1 0 -6.9 -7.1 03/04/2006 08:00:00 18.7 1.6 22.1 14.9 18.5 1.6 21.8 14.5 68 5 62 305 -7.1 0 -6.7 -7.3 03/04/2006 08:10:00 18.6 1.7 22.6 14.1 18.3 1.8 22.9 14.1 67 5 62 305 -7.1 0 -6.7 -7.3 03/04/2006 08:20:00 18.4 1.7 22.6 14.1 18.2 1.7 22.6 12.6 68 5 73 305 -7.1 0 -6.9 -7.3 03/04/2006 08:30:00 18 1.7 22.6 14.1 17.8 1.6 21.8 12.6 67 5 62 305 -7.2 0 -6.9 -7.5 03/04/2006 08:40:00 17.6 1.4 21.4 14.1 17.3 1.4 21.4 13.3 67 5 64 305 -7.3 0 -6.9 -7.5 03/04/2006 08:50:00 16.4 1.7 21.4 11.8 16 1.7 21.4 11.8 64 6 66 305 -7.5 0.1 -7.1 -7.7 03/04/2006 09:00:00 17.1 1.9 21 13 16.8 2 21 12.2 64 5 56 305 -7.6 0 -7.3 -7.7 03/04/2006 09:10:00 16.1 1.7 20.6 11.8 15.8 1.8 21 11.1 65 6 62 305 -7.7 0 -7.3 -7.7 03/04/2006 09:20:00 16.7 1.6 20.2 13.3 16.4 1.5 20.2 13.3 64 6 65 305 -7.7 0 -7.3 -7.9 03/04/2006 09:30:00 17 1.5 21 13 16.7 1.5 20.6 13 65 5 62 305 -7.8 0 -7.5 -7.9 03/04/2006 09:40:00 16.6 1.8 21.8 12.6 16.5 1.9 21 11.8 64 6 74 305 -7.8 0 -7.7 -7.9 03/04/2006 09:50:00 16.3 1.6 20.6 11.8 16.1 1.6 20.6 12.6 64 6 69 305 -7.8 0 -7.5 -7.9 03/04/2006 10:00:00 16.4 1.8 21.4 13 16.1 1.8 21.4 11.5 65 6 76 305 -7.9 0 -7.7 -8.2 03/04/2006 10:10:00 16.7 1.9 21 12.6 16.2 2.1 21 11.8 62 6 62 305 -7.9 0 -7.7 -8.2 03/04/2006 10:20:00 16.5 2 21.8 11.8 16.1 1.9 21.4 11.5 61 6 60 305 -8 0 -7.7 -8.2 03/04/2006 10:30:00 15.4 1.6 21 11.5 15.1 1.5 21 11.5 60 6 59 305 -8.2 0 -7.7 -8.2 03/04/2006 10:40:00 16.7 1.5 21.4 13.3 16.4 1.3 20.2 13.3 58 5 54 305 -8.2 0 -7.7 -8.4 03/04/2006 10:50:00 17.2 1.8 22.1 12.6 16.9 1.9 21.8 11.8 59 5 53 305 -8.4 0.1 -7.9 -8.6 03/04/2006 11:00:00 17.9 1.7 22.1 13.7 17.7 1.7 22.1 13 59 5 57 305 -8.5 0.1 -8.2 -8.8 03/04/2006 11:10:00 16.2 1.5 20.2 13 15.9 1.5 20.2 12.6 59 5 52 305 -8.6 0.1 -8.2 -8.8 03/04/2006 11:20:00 17.3 1.7 21.4 13.7 17.1 1.7 20.6 13 58 5 57 305 -8.8 0 -8.4 -9 03/04/2006 11:30:00 16.5 1.7 21 12.2 16.2 1.7 20.2 12.2 57 5 57 305 -8.8 0 -8.4 -9 03/04/2006 11:40:00 17 1.3 20.6 13 16.8 1.3 20.6 13.3 56 5 52 305 -8.8 0 -8.4 -8.8 03/04/2006 11:50:00 16.9 1.6 20.6 12.6 16.5 1.6 20.2 12.2 56 5 50 305 -8.7 0 -8.4 -8.8 03/04/2006 12:00:00 17.4 1.6 21 13 17.1 1.6 20.6 11.8 55 5 61 305 -8.7 0 -8.4 -9 03/04/2006 12:10:00 18.3 1.6 22.9 14.5 17.9 1.7 22.9 13.3 56 4 54 305 -8.8 0 -8.6 -9 03/04/2006 12:20:00 17.2 1.5 20.6 13.3 16.9 1.7 20.6 12.6 55 5 52 305 -8.7 0 -8.4 -8.8 03/04/2006 12:30:00 16.4 1.7 20.2 12.2 16 1.7 20.6 12.6 52 5 48 305 -8.6 0.1 -8.2 -8.8 03/04/2006 12:40:00 16.3 1.5 21.4 13 16 1.5 21.4 12.6 50 5 48 305 -8.6 0 -8.4 -8.8 03/04/2006 12:50:00 15.6 1.5 19.1 12.6 15.3 1.5 18.7 11.5 49 5 43 305 -8.7 0 -8.4 -8.8 03/04/2006 13:00:00 16.8 1.9 21.8 12.2 16.4 2 22.1 11.8 51 5 54 305 -8.7 0 -8.4 -8.8 03/04/2006 13:10:00 17 1.5 21 13.3 16.6 1.7 21.4 12.6 50 5 48 305 -8.7 0 -8.4 -8.8 03/04/2006 13:20:00 16.2 1.7 20.6 12.2 16 1.8 21 11.5 53 6 57 305 -8.7 0 -8.4 -8.8 03/04/2006 13:30:00 15.9 1.5 19.5 12.2 15.6 1.6 19.5 12.2 52 5 57 305 -8.8 0 -8.4 -9 03/04/2006 13:40:00 17.6 1.8 21.4 12.6 17.3 1.9 21.4 12.6 51 4 52 305 -8.8 0 -8.4 -9 03/04/2006 13:50:00 16.6 1.9 20.2 11.5 16.4 1.8 20.2 11.1 50 5 53 305 -8.7 0 -8.4 -8.8 03/04/2006 14:00:00 17.8 1.6 21 13.7 17.5 1.6 21 13 48 5 44 305 -8.7 0 -8.4 -8.8 03/04/2006 14:10:00 16.3 1.7 21 12.6 16 1.7 21 11.8 44 5 49 305 -8.6 0.1 -8.2 -8.8 03/04/2006 14:20:00 16.1 1.5 19.9 12.6 15.8 1.5 19.9 12.6 42 5 40 305 -8.6 0.1 -8.2 -8.8 03/04/2006 14:30:00 17.4 1.5 20.6 12.6 17 1.5 20.2 13.3 42 5 48 305 -8.6 0.1 -8.2 -8.8 03/04/2006 14:40:00 17.2 1.7 20.2 13 16.9 1.7 21 12.6 44 5 46 305 -8.5 0 -8.2 -8.8 03/04/2006 14:50:00 16.4 1.3 18.7 13 16 1.4 19.1 12.2 39 5 30 305 -9.2 0.2 -8.2 -9.6 03/04/2006 15:00:00 16.3 1.2 19.5 12.6 15.8 1.3 18.7 13 42 5 44 305 -9.3 0 -8.8 -9.4 03/04/2006 15:10:00 16.8 1.6 20.2 12.6 16.4 1.7 20.2 12.2 38 5 37 305 -9.5 0.1 -9 -9.6 03/04/2006 15:20:00 17.6 1.5 20.6 12.6 17 1.5 20.6 13 38 5 40 305 -9.5 0 -9.2 -9.6 03/04/2006 15:30:00 15.9 1.7 20.2 12.6 15.6 1.7 20.6 11.8 36 5 38 305 -9.5 0.1 -9.2 -9.8 03/04/2006 15:40:00 16 1.3 19.1 12.6 15.7 1.3 19.1 11.8 32 5 29 305 -10 0.1 -9.4 -10.2 03/04/2006 15:50:00 16 1.5 20.2 12.2 15.6 1.4 19.5 12.2 30 5 38 305 -10.1 0 -9.8 -10.2 03/04/2006 16:00:00 14.4 1.5 18.7 9.9 14 1.5 18.7 9.5 29 5 31 305 -10.3 0.1 -9.8 -10.4 03/04/2006 16:10:00 15.6 1.4 18.7 11.1 15.2 1.3 18.7 11.5 28 5 26 305 -10.6 0.1 -10 -10.9 03/04/2006 16:20:00 16 1.4 19.5 12.2 15.7 1.4 18.7 12.2 30 5 31 305 -10.7 0 -10.4 -10.9 03/04/2006 16:30:00 14.8 1.3 17.9 11.8 14.6 1.2 17.9 11.8 29 5 32 305 -10.7 0 -10.4 -10.9 03/04/2006 16:40:00 15.1 1.5 18.7 11.5 14.6 1.6 18.3 9.9 27 5 31 305 -10.8 0.1 -10.4 -10.9 03/04/2006 16:50:00 15.7 1.3 18.7 11.8 15.4 1.4 18.3 11.5 26 5 28 305 -10.9 0 -10.7 -11.1 03/04/2006 17:00:00 16 1.3 18.7 13 15.6 1.3 18.3 11.8 26 5 25 305 -11 0 -10.7 -11.3 03/04/2006 17:10:00 15.9 1.2 19.1 12.2 15.3 1.2 18.3 11.8 28 5 29 305 -11.1 0 -10.9 -11.3 03/04/2006 17:20:00 15.6 1.3 18.3 12.2 15.2 1.3 17.9 11.8 27 5 31 305 -11.1 0 -10.9 -11.3 03/04/2006 17:30:00 16 1.2 19.1 13 15.6 1.2 18.3 12.6 27 5 29 305 -11.1 0 -10.9 -11.3 03/04/2006 17:40:00 15.9 1.4 19.1 13 15.5 1.3 18.7 11.8 28 5 19 305 -11 0 -10.9 -11.3 03/04/2006 17:50:00 15.2 1.5 19.1 12.2 14.9 1.5 18.3 11.8 26 5 21 305 -10.9 0 -10.4 -11.1 03/04/2006 18:00:00 15.6 1.4 18.7 11.5 15.3 1.3 19.1 11.8 26 5 23 305 -10.9 0 -10.7 -11.1 03/04/2006 18:10:00 15.3 1.5 19.1 11.8 15 1.5 18.7 11.1 27 5 30 305 -10.9 0 -10.7 -11.1 03/04/2006 18:20:00 15 1.5 17.9 11.1 14.8 1.5 17.6 11.1 25 5 27 305 -11.1 0 -10.9 -11.3 03/04/2006 18:30:00 15.3 1.5 18.3 11.1 14.9 1.5 18.3 10.7 26 5 27 305 -11.1 0 -10.9 -11.3 03/04/2006 18:40:00 14.4 1.7 17.9 10.7 14 1.7 17.9 10.3 25 5 25 305 -11.1 0 -10.9 -11.3 03/04/2006 18:50:00 13.4 1.1 17.2 10.3 13.3 1.1 16.1 9.9 23 5 29 305 -11.2 0 -10.9 -11.3 03/04/2006 19:00:00 14.6 1.7 17.9 10.7 14.1 1.8 17.9 9.9 24 5 22 305 -11.2 0 -10.9 -11.5 03/04/2006 19:10:00 15.3 1.5 18.3 11.1 15 1.6 18.3 10.7 22 5 20 305 -11.3 0.1 -10.9 -11.5 03/04/2006 19:20:00 15 1.7 18.7 10.3 14.6 1.7 18.3 9.9 22 5 21 305 -11.5 0 -11.3 -11.7 03/04/2006 19:30:00 15.1 1.3 18.3 11.5 14.7 1.3 18.3 11.5 22 5 21 305 -11.5 0 -11.3 -11.7 03/04/2006 19:40:00 15.4 1.3 18.3 11.8 15 1.3 18.3 11.8 20 5 18 305 -11.6 0 -11.3 -11.9 03/04/2006 19:50:00 14.9 1.7 18.3 9.9 14.7 1.7 18.7 9.1 19 5 22 305 -11.7 0 -11.5 -11.9 03/04/2006 20:00:00 14.7 1.5 19.1 11.1 14.4 1.5 19.1 10.7 19 5 20 305 -12 0 -11.7 -12.1 03/04/2006 20:10:00 15 1.5 18.7 11.5 14.8 1.5 18.7 11.1 21 5 27 305 -12 0 -11.9 -12.1 03/04/2006 20:20:00 14.9 1.5 18.7 10.7 14.6 1.5 18.3 11.5 21 5 22 305 -12 0 -11.9 -12.3 03/04/2006 20:30:00 15.4 1.4 19.5 11.8 15.2 1.4 19.5 11.5 18 4 22 305 -12.1 0 -11.9 -12.3 03/04/2006 20:40:00 14.8 1.4 18.3 11.1 14.6 1.3 18.3 11.1 17 5 24 305 -12.2 0 -12.1 -12.5 03/04/2006 20:50:00 16.5 1.3 19.9 12.6 16.2 1.3 19.9 13 15 4 15 305 -12.3 0 -12.1 -12.5 03/04/2006 21:00:00 16.4 1.5 20.2 12.2 16 1.6 19.9 11.8 16 5 17 305 -12.2 0 -12.1 -12.5 03/04/2006 21:10:00 16.4 1.5 19.1 11.5 16.1 1.5 19.1 11.5 16 4 17 305 -12.2 0 -12.1 -12.5 03/04/2006 21:20:00 16.9 1.7 20.2 11.8 16.6 1.7 20.2 11.1 18 5 23 305 -12.2 0 -12.1 -12.5 03/04/2006 21:30:00 16 1.3 19.1 13 15.8 1.3 19.1 12.6 19 5 11 305 -12.2 0 -12.1 -12.5 03/04/2006 21:40:00 15.6 1.5 17.9 12.2 15.2 1.4 18.7 11.5 18 5 23 305 -12.3 0.1 -12.1 -12.5 03/04/2006 21:50:00 16 1.4 18.7 12.6 15.7 1.5 19.9 11.5 19 5 18 305 -12.4 0 -12.1 -12.5 03/04/2006 22:00:00 15 1.6 18.3 11.5 14.8 1.6 17.9 10.7 18 5 15 305 -12.3 0 -12.1 -12.5 03/04/2006 22:10:00 15 1.5 17.9 11.5 14.8 1.4 18.3 11.5 17 5 20 305 -12.3 0 -12.1 -12.5 03/04/2006 22:20:00 14.8 1.7 19.1 11.1 14.7 1.5 18.7 11.5 16 5 20 305 -12.3 0 -12.1 -12.5 03/04/2006 22:30:00 14.6 1.5 17.9 9.9 14.2 1.6 17.2 8.8 15 5 13 305 -12.3 0 -12.1 -12.5 03/04/2006 22:40:00 15.2 1.5 18.7 11.1 15 1.5 17.9 10.3 16 5 13 305 -12.3 0 -12.1 -12.5 03/04/2006 22:50:00 13.8 1.6 17.9 9.9 13.5 1.5 17.6 10.3 17 5 10 305 -12.3 0 -12.1 -12.5 03/04/2006 23:00:00 12.8 1.3 16.1 9.5 12.6 1.3 16.4 9.1 17 5 19 305 -12.2 0 -12.1 -12.5 03/04/2006 23:10:00 13.1 1.6 16.8 9.5 12.9 1.7 17.6 8.8 17 5 17 305 -12.2 0 -12.1 -12.3 03/04/2006 23:20:00 12.3 1.7 16.4 8.4 12.2 1.7 16.8 8.4 18 6 15 305 -12.1 0 -11.9 -12.3 03/04/2006 23:30:00 13.4 1.4 17.2 9.1 13.2 1.4 16.8 9.5 18 5 16 305 -12.2 0 -11.9 -12.5 03/04/2006 23:40:00 14 1.7 17.2 10.3 13.7 1.7 16.8 9.9 18 5 21 305 -12.2 0 -12.1 -12.5 03/04/2006 23:50:00 13.3 1.6 17.2 9.5 13.2 1.5 17.2 9.9 17 5 17 305 -12.4 0.1 -12.1 -12.5 03/05/2006 00:00:00 14.3 1.3 17.2 10.3 14 1.3 17.2 11.1 18 5 18 305 -12.5 0 -12.1 -12.5 03/05/2006 00:10:00 13.6 1.3 17.6 10.7 13.3 1.4 17.2 9.9 18 5 15 305 -12.5 0 -12.1 -12.5 03/05/2006 00:20:00 12.8 1.5 16.1 9.1 12.5 1.5 15.6 9.1 18 5 21 305 -12.4 0.1 -12.1 -12.5 03/05/2006 00:30:00 13.1 1.3 16.1 10.3 12.9 1.4 16.8 9.5 17 5 9 305 -12.4 0.1 -12.1 -12.5 03/05/2006 00:40:00 14 1.1 17.2 11.5 13.8 1.2 17.2 10.7 17 5 14 305 -12.4 0.1 -12.1 -12.5 03/05/2006 00:50:00 13.1 1.1 16.1 10.3 12.7 1.1 15.3 10.3 19 5 18 305 -12.4 0.1 -12.1 -12.5 03/05/2006 01:00:00 11.5 1.4 15.6 8.8 11.4 1.4 15.6 8.4 15 5 18 305 -12.2 0 -12.1 -12.5 03/05/2006 01:10:00 11.5 1.5 16.4 8.8 11.2 1.4 15.3 8.4 16 6 13 305 -12.3 0 -12.1 -12.5 03/05/2006 01:20:00 11.6 0.9 14.1 9.1 11.5 1 14.1 8.4 19 5 24 305 -12.3 0 -12.1 -12.5 03/05/2006 01:30:00 8.8 1.4 12.6 6.1 8.7 1.4 13 6.1 7 8 27 305 -12.7 0.2 -12.1 -13.1 03/05/2006 01:40:00 8.8 1 11.1 6.5 8.6 0.9 11.1 6.5 5 5 8 305 -13.3 0 -12.9 -13.5 03/05/2006 01:50:00 9 0.8 11.1 7.2 8.9 0.8 11.1 6.8 3 5 11 305 -13.5 0 -13.3 -13.7 03/05/2006 02:00:00 8.6 0.8 10.7 6.8 8.5 0.7 10.7 6.8 2 5 356 305 -13.8 0.1 -13.3 -14.1 03/05/2006 02:10:00 8.6 0.9 11.1 6.1 8.5 0.9 10.7 6.5 1 4 11 305 -14 0 -13.7 -14.3 03/05/2006 02:20:00 7.7 0.7 9.9 5.7 7.6 0.7 9.9 5.7 1 5 5 305 -14.2 0 -13.9 -14.3 03/05/2006 02:30:00 7.4 0.9 9.9 5.7 7.3 0.9 9.9 5.3 358 7 10 305 -14.2 0 -14.1 -14.3 03/05/2006 02:40:00 7.7 0.9 9.9 4.9 7.6 1 9.5 5.3 0 6 358 305 -14.2 0 -14.1 -14.3 03/05/2006 02:50:00 7.8 0.9 10.7 5.7 7.7 0.8 10.7 5.3 359 7 354 305 -14.3 0 -14.1 -14.4 03/05/2006 03:00:00 8.8 1.1 11.1 5.7 8.9 1.1 11.8 6.1 3 5 7 305 -14.4 0 -14.3 -14.6 03/05/2006 03:10:00 8.9 1 11.1 6.5 8.9 1 11.1 6.5 2 5 2 305 -14.6 0.1 -14.3 -14.6 03/05/2006 03:20:00 8.6 1.3 12.2 5.7 8.5 1.3 12.2 5.7 1 5 357 305 -14.7 0 -14.6 -14.8 03/05/2006 03:30:00 8.9 1.2 12.2 6.1 8.9 1.1 12.2 6.1 0 6 358 305 -14.8 0 -14.6 -14.8 03/05/2006 03:40:00 9.9 1 13 7.6 9.8 1.1 12.6 6.8 2 6 357 305 -15 0 -14.6 -15 03/05/2006 03:50:00 10.1 1.2 13 6.8 9.9 1.2 12.6 7.2 7 5 7 305 -15 0 -14.8 -15 03/05/2006 04:00:00 10.4 1.1 13.3 7.2 10.2 1.1 13.3 8 8 5 10 305 -14.9 0 -14.6 -15 03/05/2006 04:10:00 10 0.9 12.6 8 9.9 1 12.6 7.2 10 6 1 305 -14.8 0 -14.6 -14.8 03/05/2006 04:20:00 9.6 1.1 12.2 6.8 9.5 1.1 12.6 7.2 10 6 7 305 -14.7 0 -14.4 -14.8 03/05/2006 04:30:00 9.8 1.2 12.6 7.2 9.7 1.2 12.6 6.8 11 6 8 305 -14.5 0 -14.3 -14.6 03/05/2006 04:40:00 9.9 1.3 13.7 7.2 9.9 1.4 14.1 6.8 12 5 12 305 -14.4 0 -14.3 -14.6 03/05/2006 04:50:00 11 1 13.3 8.8 10.9 1 13.3 8 9 5 9 305 -14.4 0 -14.3 -14.4 03/05/2006 05:00:00 11.1 1.1 13.7 8.4 11 1.2 14.1 8 9 5 16 305 -14.4 0 -14.3 -14.6 03/05/2006 05:10:00 9.7 1.3 12.6 6.1 9.5 1.3 12.6 6.5 10 5 10 305 -14.4 0 -14.3 -14.6 03/05/2006 05:20:00 10.6 1 13 7.6 10.4 1 13 8 9 5 359 305 -14.4 0 -14.3 -14.6 03/05/2006 05:30:00 9.5 1 11.8 6.5 9.2 1.1 12.2 6.5 12 6 8 305 -14.2 0 -14.1 -14.4 03/05/2006 05:40:00 8.4 1 11.1 6.1 8.3 1 11.1 6.5 13 6 12 305 -14.2 0 -13.9 -14.3 03/05/2006 05:50:00 7.2 0.8 9.9 5.3 7.1 0.7 8.8 5.3 4 6 4 305 -14.2 0 -13.9 -14.3 03/05/2006 06:00:00 7.5 1 10.3 5.3 7.4 1.1 9.9 5.3 5 6 10 305 -14.2 0 -13.9 -14.4 03/05/2006 06:10:00 7.4 0.9 10.3 5.7 7.3 0.9 10.3 5.7 6 7 25 305 -14.1 0 -13.9 -14.4 03/05/2006 06:20:00 7.4 0.8 9.9 5.7 7.4 0.8 9.5 5.3 5 6 358 305 -14.3 0 -14.3 -14.4 03/05/2006 06:30:00 8.3 1 10.3 5.3 8.2 1 11.1 5.7 10 5 10 305 -14.4 0.1 -14.3 -14.6 03/05/2006 06:40:00 8.3 1 10.7 6.1 8.2 1 10.7 5.7 6 5 6 305 -14.7 0 -14.4 -14.6 03/05/2006 06:50:00 9.1 0.8 10.7 6.8 8.9 0.8 10.7 6.5 6 5 12 305 -14.7 0 -14.6 -14.8 03/05/2006 07:00:00 8.2 0.8 10.3 6.1 8.1 0.8 9.9 6.1 8 4 8 305 -14.8 0 -14.6 -14.8 03/05/2006 07:10:00 8.1 1 10.3 5.3 8 1 10.7 5.7 10 6 11 305 -14.7 0 -14.6 -14.8 03/05/2006 07:20:00 7.7 1 11.1 5.7 7.7 1 10.7 5.7 11 5 17 305 -14.8 0 -14.6 -14.8 03/05/2006 07:30:00 7.6 0.9 9.9 5.3 7.6 0.9 10.3 5.7 9 4 4 305 -14.8 0 -14.6 -15 03/05/2006 07:40:00 8 1 10.7 5.7 8 1 10.7 5.3 6 5 5 305 -14.9 0 -14.6 -15 03/05/2006 07:50:00 10.6 1.4 13.7 6.8 10.6 1.5 13.7 6.8 8 5 7 305 -14.8 0 -14.6 -15 03/05/2006 08:00:00 9.9 1.1 12.2 6.8 9.8 1.1 13 7.2 8 6 12 305 -14.9 0 -14.6 -15 03/05/2006 08:10:00 8.9 1.5 13 6.1 8.9 1.5 12.6 6.1 5 7 10 305 -14.9 0 -14.6 -15 03/05/2006 08:20:00 10 1.1 13 7.2 9.9 1 13.3 7.6 11 5 22 305 -15.1 0 -15 -15.2 03/05/2006 08:30:00 9.9 1 12.6 7.2 9.7 1 12.6 7.2 11 6 9 305 -15.1 0 -15 -15.2 03/05/2006 08:40:00 10.3 1.2 12.6 6.8 10.2 1.3 13 7.6 9 6 12 305 -15.1 0 -14.8 -15.2 03/05/2006 08:50:00 9 1.4 13 5.3 8.9 1.4 13 5.7 11 7 14 305 -15.3 0 -15 -15.4 03/05/2006 09:00:00 8.6 1.1 12.6 5.7 8.3 1.1 11.1 5.3 10 7 356 305 -15.5 0 -15.2 -15.6 03/05/2006 09:10:00 9.4 1.3 12.2 6.5 9.3 1.3 12.6 6.1 8 6 8 305 -15.6 0 -15.4 -15.6 03/05/2006 09:20:00 8.6 1.2 11.8 5.7 8.4 1.2 12.2 6.1 8 6 5 305 -15.7 0 -15.6 -15.8 03/05/2006 09:30:00 8.7 0.9 11.1 6.8 8.7 1 11.1 6.5 11 5 15 305 -15.7 0 -15.6 -15.8 03/05/2006 09:40:00 9.6 1 12.2 6.5 9.6 1 12.2 6.5 7 6 359 305 -15.7 0 -15.6 -15.8 03/05/2006 09:50:00 8.7 0.8 11.1 6.5 8.7 0.8 11.1 6.5 3 5 4 305 -15.8 0 -15.6 -15.8 03/05/2006 10:00:00 9.2 1 11.8 6.5 9.2 1 12.6 6.8 6 5 0 305 -15.8 0 -15.6 -15.8 03/05/2006 10:10:00 8.7 1 11.1 6.5 8.5 1 11.1 6.1 7 5 5 305 -15.8 0 -15.6 -15.8 03/05/2006 10:20:00 7.8 0.8 9.9 6.1 7.8 0.8 9.9 5.7 8 5 9 305 -15.8 0 -15.6 -15.8 03/05/2006 10:30:00 8.5 1 11.5 6.1 8.4 1 10.7 6.1 9 6 2 305 -15.7 0 -15.4 -15.8 03/05/2006 10:40:00 8.1 0.8 10.7 6.1 7.9 0.8 11.1 6.1 9 7 13 305 -15.5 0 -15.2 -15.6 03/05/2006 10:50:00 7.9 0.8 9.9 6.1 7.7 0.8 9.9 5.3 13 5 14 305 -15.4 0 -15.2 -15.6 03/05/2006 11:00:00 6.8 0.7 8.4 4.2 6.6 0.7 8.4 4.9 15 6 8 305 -15.3 0 -15 -15.6 03/05/2006 11:10:00 7.9 0.9 9.9 5.7 7.6 1 9.9 5.7 15 6 11 305 -15.1 0.1 -14.8 -15.2 03/05/2006 11:20:00 8.5 1 10.7 5.7 8.3 1 11.1 5.7 13 5 8 305 -15 0 -14.6 -15 03/05/2006 11:30:00 8.6 1 11.1 6.1 8.4 1.1 11.5 6.1 9 5 13 305 -14.9 0 -14.6 -15 03/05/2006 11:40:00 8.1 0.8 9.9 6.1 8 0.8 9.9 6.1 9 5 7 305 -14.9 0 -14.6 -15 03/05/2006 11:50:00 7.6 0.7 9.5 6.1 7.4 0.8 9.5 5.3 11 5 5 305 -14.8 0 -14.4 -15 03/05/2006 12:00:00 9 1 11.5 6.8 8.8 1 11.8 6.5 12 5 10 305 -14.7 0 -14.4 -14.8 03/05/2006 12:10:00 9.1 0.8 12.2 6.8 8.9 0.9 11.1 6.5 14 5 12 305 -14.7 0 -14.4 -14.8 03/05/2006 12:20:00 9.3 1 11.5 6.8 9.2 1 11.5 6.8 15 5 24 305 -14.7 0 -14.4 -14.8 03/05/2006 12:30:00 9 0.8 11.1 6.8 8.9 0.8 11.1 6.5 15 5 19 305 -14.7 0 -14.6 -14.8 03/05/2006 12:40:00 8.4 1.2 11.5 5.3 8.4 1.2 11.5 6.1 19 5 16 305 -14.7 0 -14.6 -14.8 03/05/2006 12:50:00 8.4 1 10.7 6.1 8.4 1 11.1 6.1 20 6 19 305 -14.7 0 -14.6 -14.8 03/05/2006 13:00:00 9.2 0.8 11.1 7.2 9.2 0.9 11.5 6.8 16 5 7 305 -14.7 0 -14.4 -14.8 03/05/2006 13:10:00 9.4 0.8 11.1 7.6 9.3 0.9 11.1 6.8 18 4 22 305 -14.7 0 -14.4 -14.8 03/05/2006 13:20:00 8.9 0.8 11.1 6.5 8.9 0.8 10.7 6.8 20 4 21 305 -14.7 0 -14.6 -14.8 03/05/2006 13:30:00 8.5 0.8 10.3 6.5 8.4 0.8 10.3 6.5 18 5 15 305 -14.7 0 -14.4 -14.6 03/05/2006 13:40:00 8.7 0.9 11.1 6.5 8.6 1 11.1 6.1 24 5 20 305 -14.6 0 -14.3 -14.6 03/05/2006 13:50:00 7.9 0.8 9.5 6.1 7.8 0.8 9.5 5.7 22 5 23 305 -14.6 0 -14.4 -14.6 03/05/2006 14:00:00 6.9 0.8 8.8 4.9 6.8 0.7 8.8 4.9 27 5 31 305 -14.5 0 -14.3 -14.6 03/05/2006 14:10:00 7 0.8 8.8 5.3 7 0.8 8.8 5.3 29 4 31 305 -14.4 0.1 -14.3 -14.6 03/05/2006 14:20:00 7.2 0.8 9.9 5.3 7.1 0.8 9.5 5.3 30 5 28 305 -14.5 0 -14.3 -14.6 03/05/2006 14:30:00 8.1 0.7 9.9 6.5 8.1 0.8 10.3 6.1 31 6 30 305 -14.7 0 -14.4 -14.8 03/05/2006 14:40:00 7.8 0.8 9.5 5.3 7.7 0.8 9.5 5.7 35 5 35 305 -14.7 0 -14.4 -15 03/05/2006 14:50:00 7.8 0.6 9.5 6.1 7.8 0.6 9.9 6.1 30 5 24 305 -14.7 0 -14.4 -14.8 03/05/2006 15:00:00 8 0.9 10.3 6.1 8 0.9 10.3 5.7 31 7 26 305 -14.7 0 -14.3 -14.8 03/05/2006 15:10:00 7.4 0.5 8.8 5.7 7.4 0.6 8.4 5.7 38 5 46 305 -14.7 0 -14.4 -14.8 03/05/2006 15:20:00 7.3 0.7 9.5 5.7 7.2 0.7 9.1 5.7 36 5 32 305 -14.7 0 -14.4 -14.8 03/05/2006 15:30:00 7.5 0.7 9.1 5.7 7.5 0.7 9.5 5.7 34 6 25 305 -14.7 0 -14.3 -14.8 03/05/2006 15:40:00 7.5 0.6 8.8 5.3 7.4 0.6 8.8 6.1 37 5 42 305 -14.7 0 -14.3 -15 03/05/2006 15:50:00 7.5 0.6 8.8 5.7 7.5 0.6 8.8 5.7 38 4 36 305 -15 0 -14.6 -15 03/05/2006 16:00:00 7.1 0.6 8.4 5.7 7.1 0.6 8.4 5.3 33 5 39 305 -14.8 0 -14.4 -15 03/05/2006 16:10:00 6.9 0.6 8.8 5.3 6.9 0.6 8.8 5.3 27 6 32 305 -14.8 0 -14.4 -15 03/05/2006 16:20:00 7.2 0.7 9.1 5.7 7.1 0.8 8.8 5.7 40 5 47 305 -15 0.1 -14.6 -15.2 03/05/2006 16:30:00 7.8 0.6 9.1 5.7 7.8 0.7 9.1 6.1 40 4 42 305 -15.2 0 -14.8 -15.4 03/05/2006 16:40:00 8.3 0.6 9.5 6.8 8.2 0.6 9.5 6.5 38 4 36 305 -15.3 0 -15 -15.6 03/05/2006 16:50:00 8.5 0.6 9.9 6.8 8.4 0.6 9.5 6.5 36 5 48 305 -15.5 0 -15.2 -15.6 03/05/2006 17:00:00 8 0.8 9.5 5.7 8 0.8 9.5 6.1 30 4 30 305 -15.7 0.1 -15.2 -15.8 03/05/2006 17:10:00 7.6 0.5 9.1 6.1 7.5 0.6 8.8 5.7 41 5 43 305 -15.8 0 -15.6 -16 03/05/2006 17:20:00 7.9 0.5 9.1 6.5 7.9 0.5 9.1 5.7 44 3 49 305 -15.8 0 -15.8 -16 03/05/2006 17:30:00 7.1 0.5 8 5.7 7.1 0.5 8.4 5.7 45 3 51 305 -15.9 0 -15.8 -16 03/05/2006 17:40:00 7.1 0.4 8.4 6.1 7.1 0.5 8 6.1 43 5 37 305 -16 0 -15.8 -16.2 03/05/2006 17:50:00 7.9 0.5 9.1 5.7 7.9 0.5 9.1 6.1 40 4 40 305 -16.2 0 -16 -16.4 03/05/2006 18:00:00 7.9 0.6 9.1 6.5 7.8 0.6 9.1 6.1 39 4 38 305 -16.3 0 -16 -16.6 03/05/2006 18:10:00 8 0.6 9.5 6.1 7.9 0.6 9.5 6.1 36 5 35 305 -16.4 0 -16.4 -16.6 03/05/2006 18:20:00 6.9 0.6 8.4 5.7 6.9 0.6 8.4 5.3 38 5 39 305 -16.6 0 -16.4 -16.9 03/05/2006 18:30:00 7.2 0.7 8.8 5.3 7.1 0.7 8.8 5.3 42 5 48 305 -16.8 0 -16.6 -16.9 03/05/2006 18:40:00 7.6 0.6 9.1 6.1 7.5 0.6 8.8 6.1 46 4 48 305 -17 0 -16.9 -17.3 03/05/2006 18:50:00 8.6 0.6 9.9 7.2 8.6 0.7 10.3 7.2 46 4 43 305 -17.2 0 -16.9 -17.3 03/05/2006 19:00:00 7.9 0.6 9.5 6.1 7.8 0.6 9.1 6.1 44 4 45 305 -17.2 0 -16.9 -17.3 03/05/2006 19:10:00 8.2 0.6 9.9 6.8 8.1 0.7 9.9 6.5 42 5 38 305 -17.3 0 -16.9 -17.5 03/05/2006 19:20:00 9 0.7 10.7 6.8 8.9 0.8 10.7 6.5 40 5 40 305 -17.5 0 -17.3 -17.5 03/05/2006 19:30:00 8.4 0.8 10.3 6.5 8.3 0.8 10.3 6.5 36 4 33 305 -17.6 0 -17.3 -17.7 03/05/2006 19:40:00 8.6 0.8 10.3 6.5 8.5 0.8 10.7 6.5 34 5 31 305 -17.7 0 -17.5 -17.9 03/05/2006 19:50:00 8 0.5 9.1 6.8 7.9 0.5 9.1 6.5 36 4 30 305 -17.9 0 -17.7 -18.1 03/05/2006 20:00:00 8.9 0.7 10.7 7.2 8.8 0.7 11.1 6.8 34 3 37 305 -17.9 0 -17.7 -18.1 03/05/2006 20:10:00 9.4 0.7 11.5 6.8 9.2 0.8 11.1 6.8 35 4 40 305 -18 0 -17.9 -18.1 03/05/2006 20:20:00 9.5 0.7 11.1 7.6 9.3 0.8 11.1 7.2 38 5 40 305 -18 0 -17.9 -18.1 03/05/2006 20:30:00 8.7 0.6 10.3 7.2 8.6 0.6 9.9 7.2 38 5 30 305 -18.1 0 -18.1 -18.2 03/05/2006 20:40:00 9.6 0.6 11.5 8 9.5 0.6 11.5 7.6 38 5 46 305 -18.2 0 -18.1 -18.4 03/05/2006 20:50:00 9.4 0.6 10.7 7.6 9.3 0.6 11.1 7.2 34 4 38 305 -18.2 0 -18.1 -18.4 03/05/2006 21:00:00 9.3 0.6 11.1 7.6 9.1 0.6 11.1 7.6 34 4 31 305 -18.2 0 -18.1 -18.4 03/05/2006 21:10:00 8.8 0.7 10.7 7.2 8.5 0.7 10.3 6.8 34 5 31 305 -18.2 0 -18.1 -18.4 03/05/2006 21:20:00 10 0.7 11.5 8.4 9.9 0.7 11.5 8 32 5 31 305 -18.3 0 -18.1 -18.4 03/05/2006 21:30:00 9.3 0.8 11.1 7.2 9.2 0.9 11.8 6.8 35 5 34 305 -18.3 0.1 -17.7 -18.4 03/05/2006 21:40:00 9.6 0.8 11.5 7.6 9.5 0.8 11.8 7.2 34 4 40 305 -18.4 0.1 -17.9 -18.4 03/05/2006 21:50:00 9.5 1 12.6 7.2 9.4 1 12.6 7.2 33 4 36 305 -18.5 0 -18.1 -18.6 03/05/2006 22:00:00 8 0.6 9.5 6.5 8 0.7 9.5 6.1 35 5 33 305 -18.6 0 -18.1 -18.6 03/05/2006 22:10:00 8.8 1 11.5 6.5 8.6 1.1 11.5 6.5 38 5 25 305 -18.7 0.1 -18.1 -19 03/05/2006 22:20:00 9.7 0.8 11.8 7.6 9.4 1 11.8 7.2 33 5 30 305 -18.7 0.1 -18.1 -19 03/05/2006 22:30:00 10 0.8 11.5 6.8 9.8 0.8 11.5 6.8 35 4 32 305 -18.8 0.1 -18.2 -19 03/05/2006 22:40:00 8.3 0.7 10.3 6.5 8.1 0.7 9.9 6.1 32 3 33 305 -18.9 0.1 -18.4 -19 03/05/2006 22:50:00 8.6 0.5 9.9 7.2 8.4 0.6 9.9 6.5 34 3 36 305 -18.9 0.1 -18.4 -19 03/05/2006 23:00:00 7.4 0.6 8.8 5.7 7.2 0.7 8.8 5.3 44 6 42 305 -19 0.1 -18.4 -19.2 03/05/2006 23:10:00 7.8 0.6 9.5 6.1 7.6 0.6 9.5 5.7 50 4 44 305 -19.1 0 -18.4 -19.2 03/05/2006 23:20:00 7.7 0.9 10.3 5.7 7.4 0.8 9.5 5.3 47 7 29 305 -19.1 0.1 -18.4 -19.3 03/05/2006 23:30:00 7.7 0.7 10.3 6.1 7.5 0.7 9.5 5.7 50 6 49 305 -19.2 0.1 -18.8 -19.5 03/05/2006 23:40:00 7.4 0.5 8.8 6.1 7.1 0.6 8.4 5.3 51 4 52 305 -19.2 0.1 -18.8 -19.5 03/05/2006 23:50:00 8.4 1 10.3 6.1 8.1 1 10.3 5.7 39 7 32 305 -19.2 0 -19 -19.5 03/06/2006 00:00:00 7.5 0.8 9.1 5.7 7.3 0.8 9.5 5.3 42 5 39 305 -19.2 0 -18.8 -19.5 03/06/2006 00:10:00 8.3 1.3 10.7 5.3 8.1 1.4 10.3 4.9 36 5 34 305 -19.4 0 -19 -19.5 03/06/2006 00:20:00 8.9 0.6 10.7 7.2 8.7 0.7 10.3 6.5 35 5 36 305 -19.5 0.1 -19 -19.5 03/06/2006 00:30:00 9.2 0.6 10.7 7.2 9 0.7 10.3 7.2 31 3 30 305 -19.6 0 -19 -19.7 03/06/2006 00:40:00 8.8 0.7 9.9 6.8 8.6 0.7 9.9 6.8 30 3 33 305 -19.7 0 -19 -19.7 03/06/2006 00:50:00 8.3 0.6 9.5 6.8 8.1 0.7 9.5 6.5 32 3 36 305 -19.6 0 -19 -19.9 03/06/2006 01:00:00 8 0.8 9.1 5.3 7.8 0.8 9.1 4.9 41 4 45 305 -19.7 0.1 -19.2 -19.9 03/06/2006 01:10:00 8.5 0.5 9.5 6.8 8.4 0.7 9.5 6.5 41 3 43 305 -19.7 0.2 -19.2 -20.1 03/06/2006 01:20:00 8.8 0.5 9.9 7.2 8.7 0.6 9.9 7.2 42 3 42 305 -19.8 0.2 -19.3 -20.1 03/06/2006 01:30:00 8 0.6 9.5 6.5 7.9 0.6 9.5 6.5 41 4 46 305 -19.8 0.2 -19.3 -20.1 03/06/2006 01:40:00 7.7 0.8 9.1 5.7 7.6 0.8 9.1 5.3 42 5 41 305 -19.9 0.2 -19.3 -20.1 03/06/2006 01:50:00 8 0.6 9.5 6.5 7.9 0.7 9.5 6.1 41 5 42 305 -19.9 0.2 -19.3 -20.1 03/06/2006 02:00:00 7.9 0.6 9.1 6.1 7.7 0.7 9.1 5.7 41 4 42 305 -20.1 0.2 -19.5 -20.2 03/06/2006 02:10:00 8.3 0.5 9.5 6.8 8.2 0.5 9.5 6.5 32 5 30 305 -20.2 0.1 -19.5 -20.2 03/06/2006 02:20:00 8.3 0.5 9.5 7.2 8.1 0.6 9.5 6.5 32 4 30 305 -20.2 0.1 -19.5 -20.2 03/06/2006 02:30:00 8.1 0.6 9.5 6.5 7.9 0.7 9.5 5.7 38 5 41 305 -20.2 0.1 -19.7 -20.2 03/06/2006 02:40:00 7.8 0.8 9.5 6.1 7.6 0.8 9.5 5.3 38 6 32 305 -20.2 0 -19.7 -20.2 03/06/2006 02:50:00 8.4 0.6 9.9 6.8 8.3 0.6 9.5 6.5 33 3 29 305 -20.2 0 -19.7 -20.2 03/06/2006 03:00:00 8.3 0.5 9.9 6.8 8.3 0.6 9.5 6.5 37 4 40 305 -20.2 0.1 -19.7 -20.2 03/06/2006 03:10:00 8 0.6 9.1 6.1 7.9 0.7 9.5 5.7 37 5 37 305 -20.2 0.1 -19.7 -20.4 03/06/2006 03:20:00 7.3 0.6 8.8 5.7 7.2 0.7 8.4 4.9 38 5 41 305 -20.2 0.1 -19.7 -20.4 03/06/2006 03:30:00 6.5 0.6 8 4.9 6.4 0.7 8 4.6 39 5 35 305 -20.3 0.2 -19.9 -20.6 03/06/2006 03:40:00 7.2 0.4 8 6.1 7.1 0.5 8 5.7 41 5 33 305 -20.5 0.2 -20.1 -20.8 03/06/2006 03:50:00 6.8 0.5 7.6 5.3 6.7 0.5 7.6 4.9 42 4 45 305 -20.6 0.1 -20.1 -20.8 03/06/2006 04:00:00 6.6 0.5 8 5.3 6.5 0.5 7.6 4.9 41 6 46 305 -20.7 0.1 -20.1 -20.8 03/06/2006 04:10:00 6.3 0.6 7.6 4.9 6.1 0.7 7.6 4.6 39 5 46 305 -20.7 0 -20.2 -20.8 03/06/2006 04:20:00 6.7 0.7 8 5.3 6.6 0.7 8 4.6 38 8 43 305 -20.7 0.1 -20.2 -20.8 03/06/2006 04:30:00 7.2 0.6 8.4 5.3 7 0.7 8.4 4.9 32 4 36 305 -20.7 0.1 -20.2 -20.8 03/06/2006 04:40:00 7.6 0.6 9.1 6.1 7.4 0.6 9.1 5.7 32 5 33 305 -20.7 0.1 -20.2 -21 03/06/2006 04:50:00 6.9 0.7 8.4 4.9 6.8 0.7 8.4 5.3 27 5 26 305 -20.9 0.1 -20.2 -21.1 03/06/2006 05:00:00 7 0.6 8.4 5.3 6.8 0.6 8 5.3 26 4 27 305 -21 0.2 -20.6 -21.3 03/06/2006 05:10:00 6.9 0.5 8.4 5.3 6.9 0.5 8.4 5.3 26 4 27 305 -21.1 0.2 -20.6 -21.3 03/06/2006 05:20:00 7.7 0.6 9.5 6.1 7.6 0.7 9.5 6.1 29 5 26 305 -21.2 0.2 -20.6 -21.3 03/06/2006 05:30:00 7.7 0.6 9.1 5.7 7.6 0.7 9.1 5.7 33 4 31 305 -21.2 0.1 -20.6 -21.3 03/06/2006 05:40:00 7.5 0.5 8.8 6.1 7.4 0.5 8.8 5.7 33 4 35 305 -21.1 0.2 -20.8 -21.3 03/06/2006 05:50:00 7 0.5 8.4 5.7 6.9 0.6 8.4 5.3 32 4 33 305 -21.2 0.1 -20.8 -21.3 03/06/2006 06:00:00 6.9 0.6 8.8 5.3 6.7 0.7 8.4 5.3 32 4 32 305 -21.2 0.2 -20.8 -21.3 03/06/2006 06:10:00 7.3 0.5 8.4 5.7 7.2 0.5 8.4 5.7 33 4 40 305 -21.2 0.1 -20.8 -21.3 03/06/2006 06:20:00 6.7 0.6 8 4.9 6.6 0.7 8 4.9 31 4 29 305 -21.3 0.2 -20.8 -21.5 03/06/2006 06:30:00 7.4 0.5 8.4 5.7 7.2 0.6 8.8 5.7 31 3 32 305 -21.3 0.2 -20.8 -21.5 03/06/2006 06:40:00 7.2 0.6 8.4 5.3 7.1 0.6 8.8 5.3 33 4 35 305 -21.4 0.1 -21 -21.7 03/06/2006 06:50:00 7.3 0.7 8.4 5.3 7.1 0.7 8.8 4.9 30 5 28 305 -21.5 0.1 -21 -21.7 03/06/2006 07:00:00 7.3 0.6 8.8 6.1 7.3 0.7 9.1 5.7 32 4 28 305 -21.4 0.1 -21 -21.7 03/06/2006 07:10:00 6.7 0.5 8 5.3 6.7 0.5 8 4.9 30 4 27 305 -21.5 0.1 -21 -21.7 03/06/2006 07:20:00 6.2 0.6 7.2 4.6 6.1 0.6 7.6 4.2 31 5 34 305 -21.6 0.1 -21.1 -21.8 03/06/2006 07:30:00 5.7 0.7 7.2 4.2 5.7 0.8 7.6 4.2 36 5 43 305 -21.6 0.1 -21.3 -21.8 03/06/2006 07:40:00 5.9 0.6 7.6 4.6 5.7 0.6 7.6 4.2 34 5 30 305 -21.6 0.1 -21.3 -21.8 03/06/2006 07:50:00 6 0.5 7.2 4.2 5.9 0.6 7.2 4.2 35 5 36 305 -21.7 0.1 -21.3 -21.8 03/06/2006 08:00:00 6 0.7 7.2 4.2 5.9 0.7 7.2 4.6 29 4 30 305 -21.7 0.2 -21.3 -21.8 03/06/2006 08:10:00 6.2 0.7 7.6 4.6 6.1 0.8 7.6 4.2 26 5 30 305 -21.7 0.2 -21.3 -21.8 03/06/2006 08:20:00 6.3 0.8 8 4.6 6.2 0.8 8 4.6 34 4 34 305 -21.7 0.2 -21.3 -21.8 03/06/2006 08:30:00 6.4 0.5 7.2 5.3 6.3 0.5 7.6 4.9 27 4 31 305 -21.7 0.1 -21.3 -21.8 03/06/2006 08:40:00 6.5 0.5 7.6 4.6 6.4 0.6 7.6 4.6 33 4 35 305 -21.9 0.1 -21.5 -22 03/06/2006 08:50:00 5.9 0.6 7.2 4.6 5.7 0.6 7.6 4.2 32 5 33 305 -22 0.1 -21.5 -22.2 03/06/2006 09:00:00 6.5 0.5 7.6 4.9 6.4 0.5 7.6 4.9 30 4 16 305 -22 0.1 -21.7 -22.2 03/06/2006 09:10:00 6.5 0.4 7.6 5.3 6.5 0.4 7.2 4.9 32 4 32 305 -22 0.1 -21.7 -22.2 03/06/2006 09:20:00 6.6 0.5 7.6 5.3 6.5 0.5 7.6 4.9 30 3 37 305 -22.1 0.1 -21.8 -22.4 03/06/2006 09:30:00 6.8 0.5 8 5.3 6.7 0.6 8 4.9 31 3 27 305 -22.1 0.1 -21.8 -22.4 03/06/2006 09:40:00 6.9 0.4 8 5.3 6.8 0.5 7.6 4.9 31 3 29 305 -22.1 0.1 -21.8 -22.4 03/06/2006 09:50:00 6.7 0.5 7.6 4.9 6.6 0.5 7.6 4.9 31 3 32 305 -22.1 0.1 -21.7 -22.4 03/06/2006 10:00:00 6.4 0.5 7.6 4.9 6.4 0.5 7.6 4.9 30 3 36 305 -22.1 0.1 -21.8 -22.4 03/06/2006 10:10:00 7 0.6 8 5.3 6.9 0.6 8 5.7 31 4 31 305 -22.2 0.1 -21.8 -22.4 03/06/2006 10:20:00 7.4 0.5 8.8 6.1 7.4 0.5 9.1 6.1 31 4 29 305 -22.2 0.1 -21.8 -22.4 03/06/2006 10:30:00 7.5 0.5 8.4 6.1 7.5 0.5 8.4 6.1 32 3 30 305 -22.2 0.2 -21.8 -22.4 03/06/2006 10:40:00 7 0.5 8.8 5.7 6.9 0.5 8.8 5.7 32 4 24 305 -22.1 0.2 -21.5 -22.4 03/06/2006 10:50:00 7.3 0.6 8.4 5.7 7.2 0.7 8.8 5.7 33 4 25 305 -22 0.2 -21.5 -22.2 03/06/2006 11:00:00 8.2 0.8 9.9 6.1 8.1 0.8 9.9 5.7 34 5 32 305 -22 0 -21.7 -22 03/06/2006 11:10:00 8.2 0.6 9.9 6.5 8.2 0.7 10.3 6.5 31 4 32 305 -21.9 0.1 -21.5 -22 03/06/2006 11:20:00 7.8 0.7 9.5 5.7 7.7 0.8 9.5 5.7 39 6 44 305 -21.7 0.1 -21.3 -22 03/06/2006 11:30:00 8.4 0.8 10.3 6.5 8.4 0.9 10.3 6.1 37 4 37 305 -21.7 0.1 -21.3 -21.8 03/06/2006 11:40:00 9.2 0.6 10.7 7.6 9.2 0.6 10.7 7.2 38 4 41 305 -21.7 0.2 -21.3 -21.8 03/06/2006 11:50:00 9.6 0.6 11.1 8 9.6 0.6 11.1 8 37 4 37 305 -21.7 0.1 -21.3 -21.8 03/06/2006 12:00:00 8.8 0.7 10.3 6.8 8.7 0.7 10.7 7.2 39 4 42 305 -21.7 0.2 -21.3 -21.8 03/06/2006 12:10:00 9.1 0.5 10.3 8 9.1 0.5 10.3 7.2 38 3 39 305 -21.5 0.2 -21.1 -21.7 03/06/2006 12:20:00 9.2 0.6 10.7 7.6 9.1 0.6 10.7 7.6 38 3 37 305 -21.4 0.2 -21 -21.7 03/06/2006 12:30:00 9.2 0.6 10.7 7.2 9 0.7 10.3 7.2 36 5 38 305 -21.3 0.2 -20.8 -21.7 03/06/2006 12:40:00 8.7 0.6 10.3 7.2 8.5 0.7 10.3 6.8 30 5 30 305 -21.3 0 -20.8 -21.3 03/06/2006 12:50:00 9 0.5 10.3 7.2 8.9 0.5 10.3 7.2 32 3 30 305 -21.3 0 -20.8 -21.3 03/06/2006 13:00:00 8.3 0.6 9.9 6.5 8.1 0.6 9.5 6.8 33 4 35 305 -21.2 0.1 -20.8 -21.3 03/06/2006 13:10:00 8.4 0.7 9.9 6.5 8.3 0.7 9.9 6.1 30 5 30 305 -21 0.1 -20.4 -21.3 03/06/2006 13:20:00 7.9 1.1 10.7 6.1 7.8 1.1 10.7 5.7 28 6 18 305 -20.9 0.1 -20.4 -21.1 03/06/2006 13:30:00 8 0.6 9.5 6.5 8 0.7 9.5 5.7 27 6 37 305 -20.9 0 -20.8 -21.1 03/06/2006 13:40:00 8.2 0.7 9.9 6.5 8.1 0.7 9.9 6.5 28 4 35 305 -20.8 0 -20.8 -21 03/06/2006 13:50:00 7.6 0.6 8.8 6.1 7.5 0.7 8.8 5.7 27 5 29 305 -20.7 0 -20.6 -20.8 03/06/2006 14:00:00 7.5 0.6 8.8 5.7 7.3 0.6 9.5 6.1 28 5 32 305 -20.7 0 -20.1 -20.8 03/06/2006 14:10:00 7.6 0.6 9.1 6.1 7.5 0.6 9.1 6.1 28 5 32 305 -20.6 0 -20.4 -20.8 03/06/2006 14:20:00 8.1 0.6 9.5 6.1 8 0.7 9.5 6.1 28 5 25 305 -20.7 0 -20.8 -21 03/06/2006 14:30:00 7.5 0.6 9.1 6.1 7.5 0.7 9.1 5.7 29 4 25 305 -20.7 0 -20.4 -20.8 03/06/2006 14:40:00 6.7 0.6 8.4 4.9 6.7 0.7 8.8 4.9 27 7 24 305 -20.5 0 -20.2 -20.8 03/06/2006 14:50:00 6.8 0.6 8 4.9 6.7 0.6 8 4.6 34 4 39 305 -20.6 0.1 -19.9 -20.8 03/06/2006 15:00:00 6.4 0.5 7.6 4.9 6.4 0.5 7.6 4.9 36 5 37 305 -20.4 0 -20.2 -20.6 03/06/2006 15:10:00 6.6 0.4 7.6 4.9 6.5 0.4 7.6 4.9 34 4 34 305 -20.4 0 -20.1 -20.6 03/06/2006 15:20:00 6.5 0.7 8.8 4.9 6.4 0.7 8.4 4.9 30 6 25 305 -20.2 0 -20.1 -20.4 03/06/2006 15:30:00 6.6 0.9 9.1 4.6 6.6 0.9 8.8 4.2 26 6 19 305 -20.1 0 -19.9 -20.1 03/06/2006 15:40:00 6.8 0.5 8 4.9 6.6 0.6 8 4.6 30 5 29 305 -20 0 -19.7 -20.1 03/06/2006 15:50:00 6.9 0.6 8.4 5.3 6.9 0.6 8.8 5.3 32 6 30 305 -20 0 -19.9 -20.1 03/06/2006 16:00:00 6.7 0.8 8.4 4.9 6.6 0.8 8.8 4.9 30 6 21 305 -19.9 0 -19.7 -20.1 03/06/2006 16:10:00 6.6 0.6 7.6 4.9 6.5 0.6 8 4.9 35 5 34 305 -20 0 -19.5 -20.1 03/06/2006 16:20:00 6.8 0.5 8 5.7 6.7 0.5 8 5.3 36 5 35 305 -20 0 -19.9 -20.1 03/06/2006 16:30:00 6.5 0.6 7.6 4.6 6.4 0.6 7.6 4.6 32 5 33 305 -19.8 0 -19.5 -20.1 03/06/2006 16:40:00 6.4 0.7 8.4 4.9 6.3 0.7 8.4 4.2 27 6 32 305 -19.7 0 -19.5 -20.1 03/06/2006 16:50:00 7 0.6 8.4 5.3 6.9 0.6 8.4 4.9 26 6 24 305 -19.7 0 -19.5 -19.9 03/06/2006 17:00:00 6.8 0.6 8 5.3 6.8 0.6 8 5.3 29 4 32 305 -19.7 0 -19.5 -19.9 03/06/2006 17:10:00 7.4 0.7 8.8 5.3 7.4 0.7 8.4 5.3 22 4 21 305 -19.8 0.1 -19.5 -20.1 03/06/2006 17:20:00 6.9 0.7 8.8 4.9 6.9 0.8 8.4 4.9 17 6 24 305 -19.9 0 -19.7 -20.1 03/06/2006 17:30:00 7.5 0.6 8.8 5.7 7.5 0.7 9.1 5.7 18 5 23 305 -20 0.1 -19.7 -20.1 03/06/2006 17:40:00 7.2 0.5 8.4 5.7 7.1 0.5 8.4 5.7 20 5 21 305 -20.1 0 -19.9 -20.1 03/06/2006 17:50:00 6.7 0.7 8.4 4.9 6.7 0.8 8.4 4.9 17 5 15 305 -20.1 0 -19.9 -20.1 03/06/2006 18:00:00 6.3 0.6 8 4.6 6.2 0.7 7.6 4.6 21 6 23 305 -20.2 0 -19.9 -20.1 03/06/2006 18:10:00 6.6 0.7 8.8 4.9 6.6 0.7 8.8 4.9 17 6 14 305 -20.2 0 -20.1 -20.2 03/06/2006 18:20:00 7.1 0.6 8.4 5.3 7.1 0.6 8.4 5.3 17 6 17 305 -20.2 0 -20.1 -20.2 03/06/2006 18:30:00 7.2 0.5 8.4 5.3 7.2 0.6 8.4 5.3 16 6 18 305 -20.2 0 -20.1 -20.2 03/06/2006 18:40:00 6.7 0.6 8 4.9 6.6 0.6 8 4.6 17 6 12 305 -20.2 0 -20.1 -20.4 03/06/2006 18:50:00 6.7 0.6 8.4 4.9 6.6 0.7 8.4 4.6 15 5 21 305 -20.4 0 -20.1 -20.6 03/06/2006 19:00:00 6.5 0.5 7.6 5.3 6.4 0.6 7.6 4.9 16 4 10 305 -20.4 0 -19.9 -20.6 03/06/2006 19:10:00 6.4 0.6 7.6 4.9 6.3 0.6 8 4.9 20 4 18 305 -20.6 0.1 -20.2 -20.8 03/06/2006 19:20:00 6.7 0.7 8.4 4.6 6.6 0.8 8.4 4.9 14 5 14 305 -20.6 0 -20.1 -20.8 03/06/2006 19:30:00 7.3 0.7 8.8 5.3 7.2 0.8 9.1 4.9 12 5 8 305 -20.6 0.1 -20.1 -20.8 03/06/2006 19:40:00 7.2 0.7 8.8 5.7 7.1 0.7 8.8 5.3 15 4 16 305 -20.6 0 -20.1 -20.8 03/06/2006 19:50:00 7.3 0.7 9.1 5.3 7.2 0.7 8.8 5.3 14 5 19 305 -20.6 0 -20.4 -20.8 03/06/2006 20:00:00 7.9 0.6 9.1 5.7 7.9 0.6 9.5 6.1 15 5 18 305 -20.6 0.1 -20.1 -20.8 03/06/2006 20:10:00 7.3 0.6 8.8 5.7 7.2 0.7 8.8 5.7 11 5 11 305 -20.6 0 -20.1 -20.8 03/06/2006 20:20:00 7.8 0.7 9.5 5.7 7.7 0.8 9.5 5.7 10 5 7 305 -20.6 0 -20.4 -20.8 03/06/2006 20:30:00 8.2 0.9 9.9 6.1 8.1 0.9 9.9 5.7 11 5 13 305 -20.6 0 -20.1 -20.8 03/06/2006 20:40:00 7.4 0.8 9.1 4.9 7.3 0.8 8.8 5.3 15 5 14 305 -20.6 0.1 -20.1 -20.8 03/06/2006 20:50:00 7.6 0.7 9.5 6.1 7.7 0.7 9.5 6.1 14 5 13 305 -20.6 0.1 -20.1 -20.8 03/06/2006 21:00:00 7.8 0.7 9.5 6.1 7.7 0.8 9.1 4.9 12 8 18 305 -20.6 0.2 -20.1 -20.8 03/06/2006 21:10:00 7.8 0.7 9.1 5.7 7.7 0.7 9.5 5.7 6 5 3 305 -20.5 0.2 -20.1 -20.8 03/06/2006 21:20:00 8.1 0.7 9.1 5.7 8.1 0.7 9.5 5.7 8 5 354 305 -20.6 0.2 -20.1 -20.8 03/06/2006 21:30:00 7.4 0.8 9.1 4.6 7.4 0.9 9.1 4.9 7 4 7 305 -20.6 0.2 -20.1 -20.8 03/06/2006 21:40:00 7.1 0.6 8.8 5.3 6.9 0.8 8.4 4.9 14 6 10 305 -20.6 0.2 -20.1 -21 03/06/2006 21:50:00 7.2 0.7 8.8 5.3 7.2 0.7 8.4 5.3 16 5 17 305 -20.7 0.2 -20.1 -21 03/06/2006 22:00:00 7 0.9 8.8 4.9 6.8 1 8.8 4.9 16 4 16 305 -20.8 0.1 -20.2 -21 03/06/2006 22:10:00 7.3 0.8 9.5 5.3 7.1 0.9 9.1 5.3 13 6 16 305 -20.9 0.2 -20.2 -21.1 03/06/2006 22:20:00 7.1 1 9.1 4.6 6.9 0.9 8.8 4.9 14 5 10 305 -20.8 0.2 -20.2 -21.1 03/06/2006 22:30:00 6.6 1 8.8 4.2 6.5 1.1 9.1 4.2 13 8 12 305 -21 0.2 -20.4 -21.3 03/06/2006 22:40:00 7.9 0.7 9.9 5.3 7.9 0.7 9.5 6.1 10 5 10 305 -21 0 -20.8 -21.1 03/06/2006 22:50:00 7.6 0.7 9.5 5.7 7.5 0.7 9.5 5.3 11 5 12 305 -21 0 -20.8 -21.1 03/06/2006 23:00:00 6.6 0.8 8 4.9 6.5 0.8 8.4 4.9 12 5 8 305 -21.1 0.1 -20.6 -21.3 03/06/2006 23:10:00 6.5 0.6 8 4.9 6.4 0.6 8 4.6 11 4 9 305 -21.2 0 -21 -21.3 03/06/2006 23:20:00 5.6 0.6 7.2 3.8 5.5 0.6 7.2 4.2 13 5 13 305 -21.3 0 -21 -21.3 03/06/2006 23:30:00 6.3 1.1 9.1 4.2 6.3 1 8.8 4.6 11 6 29 305 -21.2 0 -21 -21.3 03/06/2006 23:40:00 7.7 1 9.5 4.9 7.5 1 9.9 5.3 9 5 5 305 -21.2 0 -21 -21.3 03/06/2006 23:50:00 6.7 0.7 8.4 4.9 6.7 0.7 8.4 4.9 9 5 9 305 -21.3 0 -21.1 -21.3 03/07/2006 00:00:00 7.6 0.7 9.1 4.9 7.6 0.7 9.1 5.3 8 4 7 305 -21.2 0 -21 -21.3 03/07/2006 00:10:00 7.4 0.8 9.1 5.3 7.4 0.8 9.5 4.9 7 4 5 305 -21.2 0 -21 -21.3 03/07/2006 00:20:00 6.9 0.8 8.8 4.6 6.8 0.8 8.8 4.6 10 5 8 305 -21.2 0 -20.8 -21.3 03/07/2006 00:30:00 6.7 0.7 8.4 4.6 6.7 0.8 8.8 4.6 16 6 11 305 -21.2 0 -20.8 -21.3 03/07/2006 00:40:00 6.3 0.6 8 4.9 6.3 0.6 8 4.9 18 5 18 305 -21.3 0 -21.3 -21.3 03/07/2006 00:50:00 6.3 0.9 8.8 4.6 6.1 1 8.4 4.2 15 6 15 305 -21.2 0.1 -20.8 -21.3 03/07/2006 01:00:00 6.1 0.8 8 4.2 5.9 0.8 8 4.6 12 6 8 305 -21.3 0.1 -20.8 -21.3 03/07/2006 01:10:00 5.8 0.8 8.4 4.2 5.7 0.9 8.4 4.2 20 6 18 305 -21.3 0.1 -20.8 -21.5 03/07/2006 01:20:00 7.3 0.8 9.5 4.9 7.2 0.8 8.8 5.3 13 5 17 305 -21.2 0.1 -20.8 -21.3 03/07/2006 01:30:00 7.7 0.7 9.5 6.1 7.6 0.7 9.1 6.1 14 4 16 305 -21.2 0.1 -20.8 -21.3 03/07/2006 01:40:00 7.6 0.6 9.1 5.7 7.5 0.7 9.1 4.9 15 4 18 305 -21.2 0.1 -20.8 -21.3 03/07/2006 01:50:00 7.3 0.9 9.5 4.9 7.1 0.9 8.8 4.9 17 4 16 305 -21.2 0.1 -20.8 -21.3 03/07/2006 02:00:00 6.8 0.7 8.4 4.9 6.7 0.7 8 4.9 17 4 21 305 -21.3 0.1 -20.8 -21.5 03/07/2006 02:10:00 6.4 0.6 8 4.9 6.4 0.7 8 4.6 13 5 10 305 -21.2 0.1 -20.8 -21.3 03/07/2006 02:20:00 7 0.6 8 5.3 7 0.6 8.4 5.3 15 3 15 305 -21.2 0.1 -20.8 -21.3 03/07/2006 02:30:00 6.6 0.6 8.4 5.3 6.5 0.7 8.4 4.6 16 5 17 305 -21.2 0.1 -20.8 -21.3 03/07/2006 02:40:00 7.2 0.6 8.8 5.7 7.2 0.6 9.1 5.7 17 4 13 305 -21.2 0.1 -20.8 -21.3 03/07/2006 02:50:00 6.9 0.5 8 5.3 6.8 0.7 8.4 5.3 19 4 19 305 -21.2 0.1 -20.8 -21.5 03/07/2006 03:00:00 7.6 0.5 8.4 6.1 7.5 0.5 8.8 6.1 20 4 24 305 -21.3 0.1 -20.8 -21.3 03/07/2006 03:10:00 7.4 0.6 8.8 5.3 7.3 0.6 8.8 5.3 19 5 25 305 -21.3 0.1 -21 -21.5 03/07/2006 03:20:00 7.3 0.5 8.4 5.7 7.2 0.6 8.4 5.7 20 3 25 305 -21.4 0.1 -21 -21.7 03/07/2006 03:30:00 7.3 0.6 9.1 5.7 7.3 0.7 9.1 5.7 21 4 18 305 -21.4 0.1 -21 -21.7 03/07/2006 03:40:00 7.3 0.7 8.8 5.3 7.3 0.8 8.8 4.9 17 4 22 305 -21.5 0.1 -21.1 -21.7 03/07/2006 03:50:00 6.6 0.8 8.4 4.6 6.6 0.8 8.4 4.9 21 3 22 305 -21.6 0.1 -21.3 -21.8 03/07/2006 04:00:00 6.7 0.5 8 4.9 6.7 0.6 8 5.3 20 5 27 305 -21.6 0.1 -21.3 -21.8 03/07/2006 04:10:00 6.9 0.6 8.4 5.3 6.9 0.6 8 5.3 19 5 17 305 -21.7 0.1 -21.3 -21.8 03/07/2006 04:20:00 7.4 0.5 8.8 6.1 7.3 0.5 8.8 5.7 22 3 21 305 -21.7 0.1 -21.3 -21.8 03/07/2006 04:30:00 6.6 0.6 8.4 4.9 6.5 0.6 8 4.9 23 4 19 305 -21.7 0.1 -21.3 -21.8 03/07/2006 04:40:00 6.7 0.4 7.6 5.3 6.7 0.4 8 5.7 28 3 30 305 -21.8 0.1 -21.3 -22 03/07/2006 04:50:00 6.7 0.4 7.6 5.7 6.7 0.4 7.6 5.3 31 3 31 305 -21.8 0.1 -21.3 -22 03/07/2006 05:00:00 6.9 0.5 8 5.3 6.9 0.5 8.4 4.9 30 4 32 305 -21.8 0.2 -21.3 -22 03/07/2006 05:10:00 6.4 0.6 8 4.9 6.3 0.6 7.6 4.9 25 6 21 305 -21.9 0.2 -21.3 -22.2 03/07/2006 05:20:00 7.1 0.8 9.1 5.7 7 0.8 9.1 5.3 20 6 14 305 -21.8 0.2 -21.3 -22.2 03/07/2006 05:30:00 7.2 0.7 8.4 4.9 7.2 0.7 8.8 5.3 20 5 21 305 -21.8 0.2 -21.3 -22 03/07/2006 05:40:00 7.2 0.6 8.4 5.7 7.1 0.6 8.4 5.7 25 4 24 305 -22 0.2 -21.5 -22.2 03/07/2006 05:50:00 7.6 0.5 9.1 6.1 7.6 0.5 9.1 6.1 23 4 24 305 -21.9 0.2 -21.3 -22.2 03/07/2006 06:00:00 7.4 0.6 8.8 5.7 7.3 0.7 8.8 5.3 26 5 29 305 -22 0.2 -21.5 -22.2 03/07/2006 06:10:00 7.5 0.5 8.8 6.1 7.4 0.5 8.4 6.1 27 4 28 305 -22 0.2 -21.5 -22.2 03/07/2006 06:20:00 6.8 0.6 8.8 5.7 6.7 0.6 9.1 5.3 16 5 10 305 -22.1 0.2 -21.7 -22.4 03/07/2006 06:30:00 7.4 0.7 9.1 6.1 7.2 0.7 9.5 5.7 14 4 18 305 -22.1 0.2 -21.7 -22.4 03/07/2006 06:40:00 7.2 0.7 8.8 5.7 7 0.8 8.8 4.9 12 3 15 305 -22.1 0.2 -21.7 -22.5 03/07/2006 06:50:00 7.9 0.9 9.5 5.7 7.7 1 9.5 5.3 13 3 14 305 -22.2 0.2 -21.8 -22.5 03/07/2006 07:00:00 7.6 0.6 9.1 6.1 7.5 0.7 9.1 5.7 20 3 17 305 -22.1 0.2 -21.7 -22.4 03/07/2006 07:10:00 7.3 0.8 9.5 5.7 7.2 0.8 9.5 5.3 19 4 17 305 -22.1 0.2 -21.7 -22.4 03/07/2006 07:20:00 7.6 0.5 8.8 6.1 7.5 0.5 9.1 6.1 20 3 26 305 -22 0.2 -21.7 -22.4 03/07/2006 07:30:00 7.2 0.5 8.4 6.1 7.2 0.5 8.4 5.7 22 3 21 305 -22 0.2 -21.5 -22.2 03/07/2006 07:40:00 7.1 0.5 8.4 5.3 7.1 0.6 8.8 5.7 22 5 25 305 -22 0.2 -21.5 -22.2 03/07/2006 07:50:00 6.9 0.6 8 4.9 6.8 0.6 8 4.9 20 4 20 305 -22 0.2 -21.5 -22.2 03/07/2006 08:00:00 6.6 0.6 8 4.9 6.4 0.6 8 4.9 19 3 24 305 -22.1 0.2 -21.7 -22.4 03/07/2006 08:10:00 6.2 0.5 7.2 4.9 6 0.5 7.2 4.9 19 4 17 305 -22.2 0.2 -21.7 -22.4 03/07/2006 08:20:00 6.9 0.3 8 6.1 6.8 0.4 8 5.7 22 3 20 305 -22.1 0.2 -21.7 -22.4 03/07/2006 08:30:00 6.5 0.5 7.6 4.9 6.4 0.6 7.6 4.6 21 3 21 305 -22.1 0.2 -21.7 -22.4 03/07/2006 08:40:00 6.4 0.5 8 4.9 6.3 0.6 8 4.9 21 4 25 305 -22.2 0.2 -21.7 -22.5 03/07/2006 08:50:00 7 0.5 8 5.7 7 0.5 8 5.7 21 3 19 305 -22.2 0.2 -21.8 -22.4 03/07/2006 09:00:00 7 0.7 8.4 4.9 6.9 0.7 8.4 5.3 21 3 23 305 -22.3 0.1 -21.8 -22.5 03/07/2006 09:10:00 7.2 0.5 8.4 6.1 7.2 0.5 8.4 5.7 22 4 16 305 -22.3 0.2 -21.8 -22.5 03/07/2006 09:20:00 6.7 0.9 8.8 4.9 6.6 0.8 8.8 4.9 23 5 19 305 -22.3 0.2 -21.8 -22.5 03/07/2006 09:30:00 7.3 0.6 8.4 5.7 7.1 0.6 8.4 5.3 25 5 30 305 -22.4 0.1 -21.8 -22.5 03/07/2006 09:40:00 7.1 0.5 8.4 5.3 7 0.6 8.4 5.7 25 5 24 305 -22.3 0.2 -21.8 -22.5 03/07/2006 09:50:00 7.3 0.5 8.4 5.7 7.2 0.5 8.4 5.7 21 4 18 305 -22.4 0.1 -21.8 -22.5 03/07/2006 10:00:00 6.5 0.4 7.6 4.9 6.4 0.5 7.6 4.9 23 4 22 305 -22.4 0.1 -21.8 -22.5 03/07/2006 10:10:00 6.6 0.4 7.6 5.3 6.5 0.4 7.6 5.3 26 4 28 305 -22.3 0.1 -21.8 -22.5 03/07/2006 10:20:00 6.2 0.5 7.2 4.9 6.1 0.5 7.2 4.9 28 5 31 305 -22.3 0.1 -21.8 -22.5 03/07/2006 10:30:00 6.2 0.5 7.2 4.6 6.1 0.5 7.2 4.9 26 4 29 305 -22.2 0.2 -21.8 -22.4 03/07/2006 10:40:00 5.9 0.5 6.8 4.9 5.8 0.5 6.8 4.6 17 5 19 305 -22 0.2 -21.5 -22.2 03/07/2006 10:50:00 6 0.5 7.2 4.6 5.9 0.5 6.8 4.6 16 3 11 305 -22 0.2 -21.3 -22.2 03/07/2006 11:00:00 6.8 0.6 8.4 5.3 6.8 0.6 8.4 5.3 14 4 18 305 -21.9 0.1 -21.3 -22 03/07/2006 11:10:00 6.9 0.7 8.4 4.9 6.9 0.7 8.4 4.9 14 4 17 305 -21.8 0 -21.3 -22 03/07/2006 11:20:00 7.4 0.5 8.8 6.1 7.3 0.5 8.4 5.7 13 3 13 305 -21.8 0 -21.7 -21.8 03/07/2006 11:30:00 7.4 0.7 9.1 6.1 7.3 0.8 9.5 5.7 15 4 12 305 -21.7 0 -21.3 -21.8 03/07/2006 11:40:00 8.2 0.6 9.9 6.5 8.1 0.7 9.5 6.5 15 3 14 305 -21.7 0 -21.5 -21.8 03/07/2006 11:50:00 8 0.6 9.1 6.1 7.9 0.7 9.1 6.1 15 3 13 305 -21.6 0 -21.3 -21.8 03/07/2006 12:00:00 7.1 0.7 9.1 4.9 7.1 0.7 8.4 5.3 16 6 15 305 -21.5 0 -21.3 -21.7 03/07/2006 12:10:00 7.1 0.6 8.4 5.3 7 0.7 8.4 5.3 24 5 24 305 -21.3 0 -20.8 -21.3 03/07/2006 12:20:00 7.1 0.6 8.8 5.3 7.1 0.7 9.1 5.7 23 4 22 305 -21.3 0 -20.8 -21.3 03/07/2006 12:30:00 7.4 0.5 8.8 6.1 7.4 0.6 8.8 6.1 26 4 24 305 -21.3 0 -21 -21.3 03/07/2006 12:40:00 7.4 0.5 8.8 5.7 7.3 0.5 8.4 5.7 24 5 30 305 -21.2 0.1 -20.8 -21.3 03/07/2006 12:50:00 7.1 0.6 8.4 5.3 7.1 0.6 8.4 5.7 24 5 21 305 -21.1 0 -20.8 -21.3 03/07/2006 13:00:00 6.7 0.6 8.4 4.9 6.6 0.6 8 4.9 24 5 26 305 -21 0 -20.8 -21.1 03/07/2006 13:10:00 6.7 0.5 7.6 5.3 6.6 0.6 8 4.9 25 5 25 305 -20.9 0.1 -20.8 -21.1 03/07/2006 13:20:00 7.1 0.5 8.4 5.3 7.1 0.5 8.4 5.3 22 4 25 305 -20.8 0 -20.8 -21 03/07/2006 13:30:00 7.2 0.5 8 4.9 7.1 0.6 8.4 5.3 26 5 25 305 -20.7 0 -20.6 -20.8 03/07/2006 13:40:00 6.7 0.5 8 5.3 6.6 0.5 7.6 5.3 24 5 25 305 -20.6 0 -20.4 -20.8 03/07/2006 13:50:00 6 0.5 7.2 4.6 6 0.6 7.2 4.9 16 5 23 305 -20.5 0 -20.2 -20.8 03/07/2006 14:00:00 6.7 0.5 8 5.7 6.7 0.5 8 5.7 14 4 16 305 -20.5 0 -20.2 -20.8 03/07/2006 14:10:00 6.3 0.4 7.2 5.3 6.3 0.5 7.2 4.9 16 4 19 305 -20.5 0 -20.2 -20.8 03/07/2006 14:20:00 6.1 0.5 7.6 4.6 6.1 0.6 7.2 4.6 17 5 20 305 -20.3 0.1 -19.9 -20.6 03/07/2006 14:30:00 6.8 0.5 7.6 5.3 6.7 0.5 8 5.3 20 3 21 305 -20.4 0 -20.2 -20.6 03/07/2006 14:40:00 5.8 0.6 7.2 4.6 5.9 0.6 7.2 4.2 19 6 22 305 -20.3 0 -20.1 -20.6 03/07/2006 14:50:00 5.7 0.7 7.2 4.2 5.8 0.7 7.2 4.2 18 5 26 305 -20.2 0 -20.1 -20.2 03/07/2006 15:00:00 5.7 0.5 7.2 4.2 5.7 0.5 6.8 4.2 19 6 21 305 -20.2 0 -19.5 -20.2 03/07/2006 15:10:00 5.9 0.6 7.2 4.6 5.9 0.6 7.6 4.6 20 5 23 305 -20.2 0 -20.1 -20.2 03/07/2006 15:20:00 5.7 0.5 6.8 4.2 5.7 0.5 7.2 4.2 23 5 21 305 -20.2 0 -20.1 -20.2 03/07/2006 15:30:00 5.5 0.5 6.5 4.2 5.6 0.5 6.8 4.2 25 7 13 305 -20.1 0 -19.9 -20.1 03/07/2006 15:40:00 5.4 0.4 6.5 4.2 5.4 0.4 6.5 4.6 29 5 30 305 -20 0 -19.7 -20.1 03/07/2006 15:50:00 5.4 0.6 6.8 3.8 5.5 0.5 6.8 3.8 28 5 23 305 -19.9 0 -19.7 -20.1 03/07/2006 16:00:00 5.3 0.6 6.5 3.4 5.3 0.5 6.5 3.8 23 4 27 305 -19.8 0 -19.5 -20.1 03/07/2006 16:10:00 5.7 0.4 6.8 4.2 5.7 0.4 6.8 4.6 25 4 30 305 -20 0 -19.7 -20.1 03/07/2006 16:20:00 5.3 0.4 6.1 4.2 5.4 0.5 6.5 4.2 18 5 17 305 -20 0 -19.7 -20.1 03/07/2006 16:30:00 5 0.4 6.1 3.8 5 0.4 6.1 4.2 21 4 16 305 -19.9 0 -19.7 -20.1 03/07/2006 16:40:00 4.6 0.4 5.3 3.4 4.6 0.4 5.3 3.4 22 4 19 305 -19.8 0 -19.7 -20.1 03/07/2006 16:50:00 5 0.4 5.7 3.8 5 0.4 6.1 3.8 20 4 25 305 -19.9 0 -19.7 -20.1 03/07/2006 17:00:00 4.7 0.4 5.7 3.4 4.8 0.4 5.7 3.8 22 4 19 305 -19.9 0 -19.7 -20.1 03/07/2006 17:10:00 4.1 0.5 5.3 3 4.2 0.5 5.3 3 18 5 19 305 -19.7 0 -19.5 -20.1 03/07/2006 17:20:00 4.1 0.5 5.3 2.6 4.1 0.6 5.3 2.6 12 5 9 305 -19.7 0 -19.2 -19.7 03/07/2006 17:30:00 4.6 0.5 5.7 3.8 4.7 0.5 5.7 3.4 8 0 8 305 -19.7 0 -19.5 -19.7 03/07/2006 17:40:00 4.8 0.5 5.7 3 4.9 0.5 6.1 3 9 4 12 305 -19.7 0 -19.5 -19.9 03/07/2006 17:50:00 4.9 0.4 6.1 3.8 5 0.5 6.1 3.8 8 3 14 305 -19.8 0 -19.5 -20.1 03/07/2006 18:00:00 4.9 0.4 6.1 3.8 4.9 0.4 6.1 3.8 13 4 11 305 -19.9 0 -19.7 -20.1 03/07/2006 18:10:00 5.3 0.4 6.1 4.2 5.3 0.4 6.5 4.2 19 4 15 305 -20 0.1 -19.7 -20.1 03/07/2006 18:20:00 5.3 0.5 6.1 3.8 5.2 0.5 6.1 3.8 27 8 25 305 -20.1 0 -19.9 -20.1 03/07/2006 18:30:00 5.4 0.4 6.5 4.6 5.4 0.4 6.5 4.2 36 3 39 305 -20.3 0 -20.1 -20.6 03/07/2006 18:40:00 5.4 0.4 6.5 4.2 5.3 0.5 6.5 4.2 38 3 40 305 -20.5 0 -20.2 -20.6 03/07/2006 18:50:00 5.4 0.3 6.5 4.9 5.5 0.3 6.1 4.6 36 3 34 305 -20.5 0 -20.4 -20.8 03/07/2006 19:00:00 5.4 0.4 6.1 4.2 5.4 0.5 6.5 3.8 39 4 37 305 -20.6 0 -20.4 -20.8 03/07/2006 19:10:00 5.1 0.4 6.1 3.8 5 0.5 6.1 3.8 33 6 45 305 -20.7 0 -20.6 -20.8 03/07/2006 19:20:00 5.3 0.3 6.1 4.2 5.3 0.3 6.1 4.2 31 4 34 305 -20.8 0 -20.8 -21 03/07/2006 19:30:00 5 0.4 5.7 3.8 5 0.4 5.7 3.8 31 3 30 305 -20.9 0 -20.8 -21.1 03/07/2006 19:40:00 5.3 0.3 6.1 4.6 5.2 0.4 6.1 4.2 31 3 27 305 -21.1 0.1 -20.6 -21.3 03/07/2006 19:50:00 5 0.4 6.1 4.2 4.9 0.4 5.7 3.8 27 4 35 305 -21.3 0 -21.1 -21.3 03/07/2006 20:00:00 5.1 0.4 5.7 4.2 5 0.4 6.1 4.2 31 3 31 305 -21.3 0 -20.8 -21.3 03/07/2006 20:10:00 4.9 0.4 6.1 3.8 4.8 0.4 6.1 3.8 32 5 36 305 -21.2 0.1 -20.8 -21.3 03/07/2006 20:20:00 4.6 0.3 5.3 3.8 4.7 0.3 5.3 3.8 35 2 34 305 -21.3 0.2 -20.8 -21.5 03/07/2006 20:30:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.8 39 4 38 305 -21.4 0.2 -20.8 -21.7 03/07/2006 20:40:00 4.4 0.4 5.3 3.4 4.4 0.5 5.3 3.4 43 3 45 305 -21.6 0.2 -21.3 -21.8 03/07/2006 20:50:00 3.6 0.3 4.2 3 3.7 0.3 4.2 3 37 5 41 305 -21.7 0.1 -21.3 -21.8 03/07/2006 21:00:00 3.6 0.2 4.2 3 3.7 0.2 4.2 3.4 35 2 33 305 -21.6 0.1 -21.3 -21.8 03/07/2006 21:10:00 3.7 0.4 4.6 2.6 3.9 0.4 4.6 3 38 3 40 305 -21.6 0.2 -21.3 -21.8 03/07/2006 21:20:00 3.5 0.2 4.2 3 3.7 0.2 4.2 3 39 0 39 305 -21.9 0.2 -21.3 -22.4 03/07/2006 21:30:00 3.7 0.4 4.2 3 3.8 0.4 4.6 3 41 2 39 305 -22.4 0.2 -21.8 -22.5 03/07/2006 21:40:00 4.3 0.3 4.9 3.8 4.5 0.3 4.9 3.8 43 1 42 305 -22.2 0.2 -21.7 -22.7 03/07/2006 21:50:00 4.4 0.2 4.9 3.8 4.4 0.2 4.9 3.8 41 1 40 305 -22.1 0.1 -21.7 -22.4 03/07/2006 22:00:00 4.6 0.3 5.3 4.2 4.6 0.3 5.3 4.2 39 2 34 305 -22.1 0.1 -21.7 -22.4 03/07/2006 22:10:00 4.7 0.3 5.3 4.2 4.9 0.3 5.3 4.2 36 1 37 305 -22.1 0.2 -21.8 -22.4 03/07/2006 22:20:00 5.1 0.3 5.7 4.2 5.1 0.3 5.7 4.6 40 2 40 305 -22.3 0.2 -21.8 -22.5 03/07/2006 22:30:00 4.7 0.4 5.7 3.8 4.7 0.4 6.1 3.8 39 3 38 305 -22.4 0.1 -22 -22.7 03/07/2006 22:40:00 4.6 0.4 5.3 3.8 4.6 0.4 5.7 3.8 43 3 38 305 -22.5 0.1 -22 -22.7 03/07/2006 22:50:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.8 44 2 44 305 -22.7 0.1 -22.2 -22.9 03/07/2006 23:00:00 4.2 0.3 4.9 3.4 4.1 0.3 4.9 3.4 41 3 39 305 -22.7 0.1 -22.4 -22.9 03/07/2006 23:10:00 4.9 0.4 5.7 3.8 4.9 0.4 5.7 3.8 44 2 45 305 -22.8 0.1 -22.4 -23 03/07/2006 23:20:00 5 0.3 5.7 4.6 5 0.3 5.7 4.6 43 2 45 305 -22.8 0 -22.5 -23 03/07/2006 23:30:00 5.1 0.3 5.7 4.6 5 0.4 5.7 4.2 44 2 42 305 -22.9 0.1 -22.5 -23.2 03/07/2006 23:40:00 5.4 0.3 6.1 4.6 5.3 0.3 6.1 4.6 43 2 46 305 -22.9 0.2 -22.5 -23.2 03/07/2006 23:50:00 5.7 0.3 6.5 4.6 5.7 0.4 6.5 4.6 41 3 46 305 -22.9 0.1 -22.5 -23.2 03/08/2006 00:00:00 5.8 0.4 6.8 4.9 5.7 0.4 6.8 4.9 35 2 39 305 -22.8 0.2 -22.4 -23.2 03/08/2006 00:10:00 5.3 0.5 6.8 4.6 5.3 0.4 6.5 4.2 40 3 40 305 -23 0.2 -22.5 -23.4 03/08/2006 00:20:00 6.1 0.3 6.8 5.3 6.1 0.3 6.8 4.9 34 2 36 305 -22.9 0.2 -22.4 -23.2 03/08/2006 00:30:00 5.6 0.2 6.1 4.9 5.6 0.2 6.1 4.9 32 1 31 305 -22.8 0.1 -22.4 -23 03/08/2006 00:40:00 4.9 0.3 5.7 4.2 4.9 0.4 5.7 4.2 37 2 33 305 -22.9 0.1 -22.4 -23.2 03/08/2006 00:50:00 5.2 0.3 5.7 4.6 5.1 0.3 5.7 4.2 36 3 36 305 -23 0.2 -22.5 -23.2 03/08/2006 01:00:00 5 0.3 5.7 4.2 5 0.3 5.7 4.2 38 2 41 305 -23 0.2 -22.5 -23.2 03/08/2006 01:10:00 4.5 0.2 4.9 3.8 4.6 0.2 4.9 3.8 41 3 39 305 -23.1 0.1 -22.5 -23.2 03/08/2006 01:20:00 4.8 0.3 5.3 4.2 4.7 0.3 5.3 4.2 39 3 45 305 -23.1 0.1 -22.5 -23.2 03/08/2006 01:30:00 5.3 0.3 6.1 4.6 5.2 0.4 6.1 4.2 36 2 36 305 -23 0.1 -22.5 -23.2 03/08/2006 01:40:00 5.4 0.3 6.1 4.6 5.3 0.3 6.1 4.2 36 3 34 305 -23 0.1 -22.5 -23.2 03/08/2006 01:50:00 5.3 0.3 6.5 4.6 5.2 0.4 6.5 4.2 37 3 41 305 -22.9 0.2 -22.4 -23.2 03/08/2006 02:00:00 6.1 0.4 7.2 5.3 6 0.4 7.2 4.9 39 3 45 305 -22.9 0.2 -22.4 -23.2 03/08/2006 02:10:00 5.8 0.5 6.8 4.9 5.6 0.5 6.8 4.9 37 3 37 305 -22.9 0.2 -22.4 -23.2 03/08/2006 02:20:00 5.8 0.4 6.5 4.9 5.7 0.4 6.5 4.6 32 3 35 305 -22.9 0.1 -22.4 -23.2 03/08/2006 02:30:00 5.7 0.3 6.5 4.9 5.7 0.3 6.5 4.6 36 3 36 305 -22.8 0.1 -22.4 -23 03/08/2006 02:40:00 5.3 0.4 6.5 4.6 5.4 0.4 6.1 4.6 41 3 40 305 -23 0.2 -22.5 -23.2 03/08/2006 02:50:00 4.8 0.3 5.7 4.2 4.7 0.3 5.3 3.8 42 3 42 305 -23 0.2 -22.5 -23.2 03/08/2006 03:00:00 4.3 0.3 5.3 3.4 4.2 0.3 4.9 3.4 41 4 39 305 -23 0.1 -22.5 -23.2 03/08/2006 03:10:00 3.8 0.3 4.6 2.6 3.6 0.3 4.2 2.6 34 4 35 305 -23.1 0.2 -22.5 -23.4 03/08/2006 03:20:00 4.2 0.4 5.3 3 4.1 0.4 4.9 3 28 5 30 305 -23 0.1 -22.5 -23.2 03/08/2006 03:30:00 5.2 0.3 5.7 4.6 5.1 0.3 5.7 4.2 24 3 23 305 -22.9 0.2 -22.4 -23.4 03/08/2006 03:40:00 4.7 0.4 5.7 3.8 4.7 0.4 6.1 3.8 24 4 26 305 -22.9 0.1 -22.4 -23.2 03/08/2006 03:50:00 4.4 0.3 5.3 3.4 4.2 0.3 4.9 3.4 25 6 19 305 -23 0.2 -22.4 -23.2 03/08/2006 04:00:00 4.4 0.3 5.3 3.4 4.4 0.3 4.9 3.4 27 3 29 305 -23 0.2 -22.5 -23.2 03/08/2006 04:10:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.8 31 3 28 305 -23 0.1 -22.5 -23.2 03/08/2006 04:20:00 5.2 0.4 6.1 4.2 5.2 0.5 6.1 4.2 37 5 35 305 -23.1 0.2 -22.5 -23.4 03/08/2006 04:30:00 5.5 0.4 6.1 4.6 5.6 0.4 6.1 4.6 46 1 43 305 -23.1 0.1 -22.5 -23.2 03/08/2006 04:40:00 4.8 0.4 5.7 3.8 4.8 0.4 6.1 3.8 47 0 48 305 -23.3 0.2 -22.7 -23.7 03/08/2006 04:50:00 4.1 0.3 4.6 3.4 3.9 0.4 4.6 3 47 2 48 305 -23.1 0.2 -22.5 -23.4 03/08/2006 05:00:00 4.2 0.4 5.3 3.4 4.1 0.4 4.9 3 43 5 36 305 -23.3 0.2 -22.7 -23.4 03/08/2006 05:10:00 4.3 0.4 5.3 3.4 4.2 0.4 4.9 3 40 6 33 305 -23.3 0.2 -22.9 -23.6 03/08/2006 05:20:00 4.3 0.4 4.9 3 4.2 0.3 4.9 3.4 48 3 40 305 -23.2 0.2 -22.5 -23.4 03/08/2006 05:30:00 4.8 0.2 5.3 4.2 4.6 0.3 5.3 3.4 49 0 49 305 -23.6 0.3 -22.9 -23.9 03/08/2006 05:40:00 4.3 0.4 4.9 3 4 0.4 4.9 3 47 4 49 305 -23.5 0.3 -22.7 -23.9 03/08/2006 05:50:00 4.2 0.4 5.3 3 4.1 0.4 4.9 3 41 7 25 305 -23.1 0.2 -22.5 -23.4 03/08/2006 06:00:00 4.4 0.4 5.3 3.4 4.3 0.4 5.3 3 42 9 48 305 -23.3 0.2 -22.5 -23.6 03/08/2006 06:10:00 4.9 0.5 6.1 3.8 4.7 0.5 5.7 3.4 33 6 35 305 -23.4 0.2 -22.9 -23.6 03/08/2006 06:20:00 5.6 0.6 7.2 4.6 5.3 0.6 6.8 3.8 39 4 39 305 -23.4 0.2 -22.7 -23.7 03/08/2006 06:30:00 5.9 0.5 6.8 4.6 5.7 0.6 6.8 4.2 39 5 31 305 -23.2 0.2 -22.5 -23.6 03/08/2006 06:40:00 5 0.5 6.1 3.8 4.9 0.4 6.1 3.8 45 5 44 305 -23.4 0.1 -22.9 -23.6 03/08/2006 06:50:00 6.5 0.8 7.6 4.6 6.4 0.9 8 4.2 43 4 41 305 -23.4 0.1 -22.9 -23.6 03/08/2006 07:00:00 7.1 0.4 8 6.1 7.1 0.4 8 6.1 50 3 49 305 -23.4 0.1 -22.9 -23.6 03/08/2006 07:10:00 6.6 0.5 7.6 5.3 6.5 0.5 7.6 4.9 49 4 54 305 -23.6 0.1 -23.2 -23.9 03/08/2006 07:20:00 6.3 0.5 7.2 5.3 6.2 0.5 7.2 4.9 48 5 56 305 -23.6 0.1 -23 -23.9 03/08/2006 07:30:00 6.2 0.7 8 4.6 6 0.6 7.6 4.6 45 6 40 305 -23.5 0.1 -23 -23.7 03/08/2006 07:40:00 5.6 0.4 6.5 4.6 5.5 0.4 6.5 4.6 48 3 46 305 -23.5 0.1 -23 -23.9 03/08/2006 07:50:00 5.3 0.3 6.5 4.6 5.2 0.3 6.1 4.6 51 3 52 305 -23.5 0.1 -23 -23.7 03/08/2006 08:00:00 6.3 0.3 7.2 5.7 6.1 0.4 6.8 4.9 55 4 59 305 -23.5 0.2 -22.9 -23.9 03/08/2006 08:10:00 6.6 0.4 7.2 5.3 6.4 0.6 7.2 4.9 56 3 59 305 -23.7 0.2 -23 -23.9 03/08/2006 08:20:00 6.3 0.4 7.2 5.3 6.1 0.5 6.8 4.9 57 3 57 305 -23.8 0.2 -23.2 -23.9 03/08/2006 08:30:00 5.9 0.4 6.8 4.9 5.7 0.4 6.5 4.6 58 3 61 305 -23.9 0.1 -23.4 -24.1 03/08/2006 08:40:00 5.5 0.5 6.5 3.8 5.3 0.5 6.5 3.8 57 3 60 305 -23.9 0.1 -23.4 -24.1 03/08/2006 08:50:00 4.9 0.6 6.1 3.4 4.8 0.6 6.1 3.4 56 4 57 305 -23.8 0.1 -23.4 -23.9 03/08/2006 09:00:00 5.2 0.4 6.1 4.2 5.1 0.4 6.1 4.2 52 6 53 305 -23.6 0.1 -23.2 -23.9 03/08/2006 09:10:00 4.5 0.4 5.7 3.8 4.5 0.4 5.7 3.4 48 5 50 305 -23.6 0.2 -23 -23.9 03/08/2006 09:20:00 4.2 0.4 5.3 3 4.2 0.5 5.3 2.6 48 5 62 305 -23.6 0.2 -22.9 -23.9 03/08/2006 09:30:00 3.6 0.5 4.9 2.6 3.8 0.5 4.9 2.6 47 7 44 305 -23.3 0.2 -22.7 -23.6 03/08/2006 09:40:00 3.5 0.4 4.6 2.3 3.4 0.4 4.6 2.6 50 7 48 305 -23.3 0.1 -22.9 -23.6 03/08/2006 09:50:00 2.9 0.4 4.2 2.3 2.6 0.5 3.8 1.5 62 6 60 305 -23.5 0.1 -23.2 -23.9 03/08/2006 10:00:00 2 0.4 3 1.1 1.5 0.4 2.6 0.7 69 3 58 305 -23.8 0.2 -23.2 -23.9 03/08/2006 10:10:00 1 0.5 2.3 0.4 0.6 0.3 1.5 0.4 71 0 71 305 -23.8 0.1 -23.4 -23.9 03/08/2006 10:20:00 1.6 0.4 2.6 0.4 1.2 0.4 2.3 0.4 71 0 71 305 -23.6 0.2 -23.2 -23.9 03/08/2006 10:30:00 1.7 0.6 3 0.4 1.1 0.6 2.3 0.4 71 1 70 305 -23.2 0.2 -22.5 -23.4 03/08/2006 10:40:00 2.3 0.3 3 1.5 1.7 0.4 2.6 0.4 71 1 72 305 -23.2 0.2 -22.5 -23.4 03/08/2006 10:50:00 1.9 0.4 3 1.1 1.2 0.5 2.3 0.4 62 4 64 305 -23 0.1 -22.5 -23.2 03/08/2006 11:00:00 2.1 0.5 3 1.1 1.6 0.5 3 0.7 59 5 66 305 -23.1 0 -22.5 -23.2 03/08/2006 11:10:00 3.3 0.6 4.6 1.9 2.9 0.7 4.2 1.5 58 4 63 305 -23.1 0 -22.9 -23.2 03/08/2006 11:20:00 3.5 0.7 4.6 1.9 3.2 0.6 4.6 1.5 55 7 58 305 -22.8 0.1 -22.5 -23 03/08/2006 11:30:00 3.2 0.5 4.2 2.3 2.9 0.5 4.2 1.9 52 8 45 305 -22.5 0.1 -22.4 -22.7 03/08/2006 11:40:00 3.5 0.5 4.6 2.6 3.3 0.6 4.6 2.3 55 4 56 305 -22.4 0 -22 -22.7 03/08/2006 11:50:00 4.2 0.2 4.9 3.4 4 0.3 4.6 3.4 62 3 65 305 -22.4 0.2 -22 -23.2