Loading...
HomeMy WebLinkAboutKing-Salmon1_longterm-dataKING SALMON AK - 703263 58 deg 41' N 156 deg 41' W - Elev 17m LST=GMT+99 hours *NT=-10 10/80-09/81 07/91-06/96 Adjusted to Alaska Timezone (GMT-9) SPEED BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 4.61 4.52 4.61 4.93 4.76 4.74 4.39 4.04 4.31 5.13 4.5 5.01 4.44 1980 3.82 -1 -1 -1 -1 -1 -1 -1 -1 -1 2.44 2.33 7.21 1981 5.32 1.75 -1 7.95 6.1 -1 -1 -1 12.3 6.6 -1 -1 -1 1991 5.19 -1 -1 -1 -1 -1 -1 4.55 4.18 6.39 5.32 6.08 4.65 1992 4.58 5.22 3.85 4.93 4.77 4.62 4.78 3.77 4.54 4.49 4.96 4.78 4.15 1993 4.83 5.2 5.17 5.23 4.88 4.75 4.94 4.22 4.48 5.85 3.52 5.14 4.63 1994 4.79 4.05 4.56 5.48 4.84 5.29 4.66 4.19 4.81 4.91 4.82 5.44 4.54 1995 4.14 4.01 4.41 4.89 4.6 5.13 3.85 3.5 3.5 3.99 3.9 3.68 4.17 1996 4.26 4.09 5.12 4.11 4.72 3.87 3.73 -1 -1 -1 -1 -1 -1 POWER BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 133 146 145 145 135 131 99 73 94 186 138 179 132 1980 114 -1 -1 -1 -1 -1 -1 -1 -1 -1 16 11 352 1981 298 7 -1 604 144 -1 -1 -1 1129 172 -1 -1 -1 1991 182 -1 -1 -1 -1 -1 -1 88 74 318 233 260 121 1992 120 168 61 134 104 97 119 63 110 98 152 180 152 1993 144 210 206 155 133 116 143 79 96 231 69 168 136 1994 144 93 119 220 133 151 100 84 138 181 137 236 146 1995 111 142 144 126 177 199 74 52 51 101 99 58 103 1996 110 113 197 88 124 87 57 -1 -1 -1 -1 -1 -1 NUMBER OF SPEED OBSERVATIONS BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 41301 3499 3222 3490 3342 3469 3409 3498 3578 3401 3533 3393 3467 1980 27 0 0 0 0 0 0 0 0 0 11 8 8 1981 9 4 0 2 1 0 0 0 1 1 0 0 0 1991 4184 0 0 0 0 0 0 684 708 692 714 689 697 1992 8439 718 666 704 694 718 682 710 725 697 724 687 714 1993 8309 719 647 714 694 713 687 686 727 670 701 673 678 1994 8052 680 633 681 628 670 671 708 709 666 670 649 687 1995 8384 710 655 722 706 721 694 710 708 675 713 687 683 1996 3897 668 621 667 619 647 675 0 0 0 0 0 0 NUMBER OF SPEED OBSERVATIONS BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 1709 142 127 139 143 144 140 147 145 143 151 143 145 1 1722 143 131 141 143 148 142 146 149 145 147 142 145 2 1720 146 128 139 141 146 143 149 150 142 151 146 139 3 1718 140 127 140 140 148 139 153 149 147 146 145 144 4 1714 137 130 139 142 144 143 151 147 144 151 144 142 5 1712 136 126 144 143 150 145 147 149 141 148 143 140 6 1737 146 134 151 136 149 145 148 147 143 148 143 147 7 1752 149 140 151 139 152 141 148 153 140 151 142 146 8 1731 150 138 147 145 146 141 146 146 141 142 142 147 9 1736 150 136 145 146 151 140 149 150 141 145 141 142 10 1738 146 134 146 141 148 145 149 148 146 149 143 143 11 1726 146 134 141 139 149 139 147 150 146 153 142 140 12 1724 146 134 144 140 147 145 146 148 135 153 140 146 13 1739 149 136 145 142 147 140 149 148 143 153 139 148 14 1754 146 140 146 147 146 141 140 151 143 156 147 151 15 1748 148 133 149 143 150 143 146 148 141 153 142 152 16 1736 145 135 147 143 147 144 139 154 144 145 142 151 17 1744 148 133 148 147 145 145 144 151 144 144 146 149 18 1729 145 136 149 143 146 145 142 148 142 149 142 142 19 1724 152 137 149 137 145 141 147 152 137 140 141 146 20 1656 140 137 148 128 127 139 140 151 137 137 132 140 21 1689 150 139 150 126 136 139 147 148 136 141 134 143 22 1658 149 138 146 122 131 140 140 145 138 135 137 137 23 1685 150 139 146 126 127 144 138 151 142 145 135 142 SPEED BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 4.21 4.48 4.33 4.51 4.04 3.92 3.56 3.58 3.81 5.05 4.22 4.79 4.3 1 4.16 4.29 4.41 4.5 3.98 3.92 3.53 3.6 3.66 4.75 4.22 4.74 4.35 2 4.11 4.32 4.45 4.51 3.97 3.7 3.4 3.48 3.53 4.75 4.23 4.74 4.34 3 4.07 4.37 4.33 4.58 3.85 3.57 3.34 3.45 3.43 4.58 4.12 4.95 4.38 4 4.06 4.51 4.38 4.49 3.85 3.59 3.27 3.3 3.37 4.41 4.06 4.98 4.59 5 4.09 4.27 4.64 4.4 3.94 3.49 3.28 3.33 3.38 4.62 4.24 5.16 4.55 6 4.03 4.27 4.39 4.26 3.89 3.29 3.17 3.25 3.34 4.43 4.25 5.18 4.72 7 4.03 4.26 4.47 4.17 3.85 3.5 3.29 3.35 3.28 4.33 4.13 5.21 4.66 8 4.19 4.27 4.44 4.32 4.1 4.1 3.75 3.5 3.54 4.5 4.13 5.11 4.48 9 4.41 4.52 4.38 4.64 4.37 4.58 4.31 3.78 3.94 4.67 4.25 5.08 4.46 10 4.6 4.55 4.39 4.8 4.86 4.68 4.61 4.02 4.26 5.31 4.4 4.83 4.45 11 4.85 4.79 4.72 5.3 5.21 4.97 4.66 4.12 4.66 5.6 4.81 4.92 4.47 12 5.05 4.71 4.88 5.64 5.28 5.24 4.72 4.43 4.87 5.79 5.17 5.37 4.57 13 5.16 4.87 5.02 5.83 5.71 5.34 4.89 4.49 5.09 5.82 5.32 5.23 4.34 14 5.25 4.9 5.18 5.67 5.8 5.55 5.25 4.53 5.13 5.9 5.24 5.28 4.55 15 5.46 4.96 5.51 6.06 6.08 5.72 5.51 4.69 5.36 5.93 5.49 5.56 4.68 16 5.38 4.86 5.27 5.95 5.94 5.91 5.65 4.75 5.29 6.03 5.27 5.22 4.46 17 5.33 4.62 5.07 5.8 5.98 6.25 5.53 4.92 5.41 5.91 5.03 5.15 4.26 18 5.21 4.53 4.69 5.52 5.71 6.34 5.68 4.79 5.52 5.74 4.62 4.78 4.51 19 5.01 4.44 4.44 4.97 5.74 6.06 5.63 4.83 5.27 5.41 4.2 4.74 4.4 20 4.84 4.47 4.34 4.78 5.06 6.17 5.48 4.75 4.91 5 4.13 4.88 4.23 21 4.55 4.37 4.28 4.61 4.5 5.27 4.91 4.41 4.3 4.77 4.05 4.88 4.31 22 4.34 4.44 4.26 4.58 4.13 4.57 4.19 4.02 4.09 4.76 3.95 4.87 4.24 23 4.27 4.47 4.45 4.47 4.17 4.26 3.79 3.78 3.89 4.97 4.25 4.66 4.13 POWER BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 110 139 124 119 102 80 63 51 66 206 105 169 104 1 102 114 124 112 90 85 59 55 53 180 101 153 107 2 103 117 128 122 86 74 51 51 46 177 106 174 111 3 100 131 113 119 90 59 52 50 45 135 120 178 114 4 102 141 131 116 85 69 46 48 48 124 113 180 136 5 105 127 142 111 87 62 46 44 46 136 127 196 150 6 105 131 143 101 86 57 45 42 50 119 121 207 164 7 108 128 153 107 86 61 50 47 46 118 126 200 176 8 112 134 156 107 92 89 60 50 52 150 109 194 159 9 128 159 134 135 118 122 87 57 68 148 131 222 165 10 134 157 129 139 137 118 98 69 85 206 147 153 171 11 149 168 148 189 161 134 105 72 108 241 165 153 147 12 161 167 159 209 160 162 107 90 117 229 200 183 159 13 170 180 158 228 202 172 124 91 131 235 214 184 127 14 175 188 163 188 215 196 144 94 146 255 202 175 127 15 188 186 201 237 236 204 156 107 150 248 200 195 141 16 177 170 189 207 203 193 171 112 153 243 179 184 121 17 171 140 179 191 200 209 166 108 166 234 163 192 107 18 161 128 147 163 180 224 168 110 170 221 142 150 132 19 147 141 143 120 169 196 162 105 150 190 115 144 128 20 140 145 135 119 130 211 150 99 130 178 107 176 108 21 119 135 121 108 100 144 117 81 86 152 101 180 113 22 112 136 114 113 95 119 84 70 74 144 86 194 111 23 113 143 132 114 107 105 63 60 66 189 113 171 97 SPEED BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 0 4.44 4.61 4.49 3.99 3.68 3.72 4.01 4.62 5.05 6.1 6.17 5.22 4.61 4.71 5.66 5.88 5.47 4.92 4.79 4.73 4.48 4.49 4.43 4.56 4.56 4.47 4.89 4.75 4.37 4.24 3.85 3.56 3.72 4.07 4.37 4.19 4.44 1 0 4.6 4.6 4.3 3.4 3.4 3.8 3.9 4.5 5.3 6.6 6.3 4.6 4.1 5.3 6.8 7.7 5.6 4.6 3.1 3.6 4.1 3.6 4.3 3.9 4.2 3.7 3.5 3.2 3.2 3 2.5 3.1 3.3 4 4.4 4 4.6 2 0 4.6 4.9 4.3 3.2 2.9 3 3.1 3.6 4.8 6.8 6.7 5.3 5.8 5.1 6.1 5.3 4.4 3.6 4 4.1 3.9 4.9 4.4 4.8 4.1 4.2 3.9 3.3 2.5 2.4 2.6 2.5 3.9 5 4.8 4.5 4.6 3 0 4.8 5.1 5.4 4.7 4.1 4 4.1 4.9 5.2 6.6 6.6 5.6 5.1 5.9 6.2 5.7 5.5 3.8 4.4 4.9 5.3 5.1 5 4.8 4.7 5.6 4.5 5 3.3 4.1 3.4 3.1 4.1 4 4.7 4.4 4.8 4 0 4.5 4.5 4.7 4.3 4.5 4.6 5 5.4 5.2 5.5 6 5.6 5.1 5.1 6.2 7 7 5.5 4.4 4.4 3.9 4.1 3.6 4 3.9 4 4.1 5.1 3.3 3.5 3.4 3.3 3.7 4.2 4.9 4.4 4.5 5 0 3.7 4 3.7 4.1 4.2 4.3 4.3 5 5.8 7.1 6.8 5.6 4.7 4.2 4.2 4.7 5.5 5.2 5.1 4.5 4.5 4.1 4.3 4.5 4.1 4.2 4.8 4.6 4.6 4.9 4 4.3 3.9 4.1 3.8 3.5 3.7 6 0 3.5 3.5 2.7 3 2.7 3.8 3.7 4.9 5 5.6 5.5 4.8 3.8 3.8 4.2 5.7 5.4 5.1 5.2 5.1 4.4 4.4 4.6 4.3 3.9 4.5 4.4 4.6 3.9 4.1 3.6 3.5 3.3 3.9 3.6 3.7 3.5 7 0 3.1 2.7 2.5 2.6 2.5 2.8 3 3.5 4.5 5 4.3 3.8 3.2 3.5 3.9 4.5 5 4.9 4.6 4.6 4.5 4.5 4.3 4.2 4.2 4.3 4.2 4.1 4.3 4 3.5 2.9 3.6 3.7 3.3 3.2 3.1 8 0 3.9 3.5 3.4 3.1 2.9 2.9 3 3.4 3.5 4.1 4 4.1 3.8 3.8 4.8 5.6 5.7 5.1 4.9 4.5 4.4 4.3 4.5 4.6 4.7 4.6 6 4.6 4 4.1 4.1 3.6 3.7 4 3.9 3.7 3.9 9 0 3.8 4.3 4.2 4.4 3.8 3 3.5 4.5 4.9 6.3 7.4 5.9 4.5 5.7 7.3 6.9 5.3 4.6 4.6 4.9 4.3 4.7 4.1 5.1 5.1 5 6 6 5 4.5 4.8 4.6 4 3.8 3.8 4.4 3.8 10 0 4.8 5.1 4.6 4.1 3.6 3.3 3.6 3.9 5.2 6.7 7.2 6 4.3 4.2 4.5 6.2 5.4 4.8 4.6 5.2 4.8 4.7 4.6 4.2 4.2 4.5 3.5 4.9 4.3 3.9 3.2 3.3 3.9 4.3 4.2 4.6 4.8 11 0 4.4 4.9 5 4.5 3.8 3.8 4.7 4.8 5.4 5.7 5.6 5.4 6.7 5.3 5.8 5.7 5.5 5.3 5.2 5.7 5.8 5.6 5.7 6.9 7.1 5.6 7 7.7 8.3 7.5 5.5 4.7 3.5 3.7 4.4 4.1 4.4 12 0 4.4 4.1 4.2 4 3.9 4.4 4.4 5.3 5 5.5 5.3 5.3 4 3.9 6.6 5.4 4.9 4.4 5.3 5.1 4.6 4.6 4.5 4.6 4.8 3.8 3.4 3.2 3.4 3.2 3.6 3.5 3.6 3.6 4.7 3.9 4.4 FREQUENCY BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 2.61 6.59 4.25 3.57 2.8 2.4 2.23 2.36 2.5 2.74 4.89 3.81 2.82 2.81 3.25 4.12 4.52 3.52 2.81 2.87 2.21 2.41 2.13 2.05 1.9 2.01 1.52 1.34 1.52 1.14 1.09 1.42 1.32 1.77 2.73 3.82 4.77 6.59 1 4.5 11.5 7.4 3.9 2.9 2.1 1.9 2.7 2.3 2.7 6.9 4.7 3 2.2 2.6 4 4.1 1.8 1.2 1 1.1 1.1 1.2 0.9 1.3 1 0.6 0.5 0.7 0.4 0.5 0.7 0.9 1.6 4.2 6.6 7.6 11.5 2 1.8 12.5 7.6 4.8 2.5 2.4 2.2 2 1.8 2.7 5.3 3.9 2.7 3.4 3.8 3.6 2.6 1.7 1 1.6 1.1 1.1 1.4 0.8 1 0.8 1.1 0.6 1 0.5 0.7 1.1 1.5 1.5 4.2 5.9 7.7 12.5 3 1.8 8.5 7.2 6 4.2 2.7 2.5 2.6 2.7 3 5.4 3.9 3.2 3 4.2 4.1 3.9 2.1 1 1 0.8 0.9 1 1.1 0.7 1.2 0.8 0.6 0.5 0.4 0.7 1 1.5 2 3.9 5.6 6.6 8.5 4 1.7 7.2 3.1 4.2 3.8 3.6 3.7 3.8 3.9 4 5.4 3.8 2.6 2.4 2.6 2.6 2.7 2.8 2.5 3.1 1.8 2 1.2 2 1.7 1.8 1.6 1.5 1.1 1.1 1 1.6 1 2.2 2.5 4.1 4.2 7.2 5 2.7 2.8 2.3 2.5 2.3 2.8 2.1 2.5 2.8 3.5 7.3 5.5 3.6 2.4 2.6 2.8 4.8 5 4.2 4.3 1.9 3 2.3 2 1.4 1.9 2.1 1.9 2.9 1.9 1.6 2.1 1.5 1.8 1.7 1.6 2.2 2.8 6 3.1 2.9 1.3 1.2 1.5 1.3 1.2 2.1 1.9 2.6 4.6 3.7 2.5 3.4 3.1 5 6.5 6 4.9 6 4.3 3.6 2.9 3.2 2.9 3.2 2.4 2.2 2.2 1.5 1.4 1.5 1 1.3 1.8 1.4 1.5 2.9 7 2 1.3 1.1 1 1.5 1.6 1.8 2 2 2.5 3.1 2.2 2 2.5 3.2 3.7 4.8 5.6 5.3 5.3 5 5.6 6.2 5.2 4.2 3.4 2.8 1.9 2 1.7 1.2 1.3 1 1.1 1.6 1.8 1.6 1.3 8 2.2 2.1 1.3 1.1 1.3 1.5 1.1 1.1 1.5 1.8 3.2 2.7 2.3 2.9 3.3 5 5.8 5.9 4.7 3.4 3.1 3.9 3.1 3.6 3.7 4.5 2.5 2.8 2.9 2.1 2.1 2.7 2 2.1 2.2 2.3 2.5 2.1 9 1.9 3.5 2.2 2.2 2.4 2 2 2.1 2.6 2.7 4.7 5.2 3.4 2.9 4.4 7.3 7.9 3.1 3.2 2.5 1.9 2.4 2 1.9 2 1.8 1.7 2 1.9 1.2 1.2 1.3 1.5 1.8 1.7 3.1 4 3.5 10 4.3 10 5.8 4.2 3.9 3.7 3.1 2.3 2.3 2.1 3.5 3.6 2.7 3 3 2.7 3.7 3 1.9 2.1 1.5 1.9 1.4 1.2 1.3 1.2 1.2 0.9 1.2 1 0.9 1 1.3 2.2 3.8 4.5 6.8 10 11 2.1 8.7 7 7.4 4.7 2 2.9 2.2 2.7 2.2 3.9 2.5 2.5 3.2 3.4 4.7 3.7 2.3 1.4 1.6 1.2 1.3 1 1.1 1.4 1.8 0.9 0.8 1.1 1.1 0.9 1.8 1.2 1.7 2.7 4.5 6.5 8.7 12 3.2 8.5 5.1 4.4 2.8 3 2.3 3 3.5 3.2 5.4 4.1 3.5 2.6 2.9 3.9 3.6 2.7 2.1 2.4 2.6 1.8 1.9 1.5 1.1 1.5 0.7 0.4 0.6 0.7 0.8 1 1.2 2 2.5 4.4 6.3 8.5 FREQUENCY OF SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 2.6 6.5 19 15.5 15.8 13.1 9.4 8.6 3.3 2.2 1.5 0.9 0.7 0.3 0.2 0.1 0.1 0 0.1 0 0 0 0 0 0 0 1 4.5 8.1 21.9 13.6 12.6 10.9 8.8 8.6 3.1 2.7 1.7 1.3 1 0.4 0.4 0.1 0.1 0 0 0 0 0 0 0 0 0 2 1.8 8.4 21.1 14.6 13.7 13 8.6 7.9 3.1 2.4 2.1 1.2 1.1 0.5 0.2 0.2 0 0 0.1 0 0 0 0 0 0 0 3 1.8 5 16.2 14 14.8 14.2 11.1 12.3 4.8 2.5 1.1 0.9 0.6 0.3 0.2 0.1 0.1 0 0 0 0 0 0 0 0 0 4 1.7 5.4 16.6 16.3 17.1 13.6 10.7 9.4 2.8 2.7 1.6 0.9 0.5 0.2 0.3 0.2 0 0 0.1 0 0 0 0 0 0 0 5 2.7 5.8 16.5 15.3 14.9 14.6 11.1 9.2 3.2 2.4 1.8 1.3 0.6 0.2 0.3 0 0 0 0 0 0 0 0 0 0 0 6 3.1 5.7 18.9 16.7 16.5 14.3 10.4 7.7 2.9 1.7 1.3 0.7 0.2 0 0 0 0 0 0 0 0 0 0 0 0 0 7 2 6.8 21.7 19 19.3 14.8 7 5.8 1.6 0.9 0.7 0.2 0.2 0 0 0 0 0 0 0 0 0 0 0 0 0 8 2.2 6 19.8 18.1 18.7 13.4 9.3 6.8 2.2 1.3 1.1 0.6 0.6 0.1 0 0 0 0 0 0 0 0 0 0 0 0 9 1.9 4.8 17 14.1 16.8 12.5 9.3 8.7 5.1 2.8 2.5 1.4 1.3 0.4 0.6 0.3 0.3 0.2 0.2 0 0 0 0 0 0 0 10 4.3 6.4 21.1 15.8 14.3 10.6 9.5 8.8 3.2 1.9 1 0.7 0.8 0.7 0.5 0.2 0.1 0 0.1 0 0 0 0 0 0 0 11 2.1 6 17.4 13.2 16.2 13.1 9 9.9 4.1 2.9 1.8 1.3 1.2 0.5 0.4 0.3 0.4 0.1 0.2 0 0 0 0 0 0 0 12 3.2 9.7 19.4 14.9 15.1 12.2 7.6 7.8 3.7 2.2 1.8 0.8 0.7 0.1 0.2 0.2 0.2 0.1 0.1 0 0 0 0 0 0 0 PERCENT OF POWER BY SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 0 0.1 1.2 2.7 6 9.2 11.2 16.9 9.2 8.3 7.9 6.6 6.6 3.2 3.5 2.3 2.2 0.9 1.4 0.3 0.2 0 0 0 0 0 1 0 0.1 1.3 2.3 4.6 7.3 10 15.8 8.1 9.4 8.3 8.4 8.8 4.7 5.2 1.8 2.7 0.6 0.7 0 0 0 0 0 0 0 2 0 0.1 1.3 2.5 5 8.9 9.8 15 8.2 8.6 10.2 7.8 9.4 4.9 2.4 2.9 0.6 0.7 1.6 0 0 0 0 0 0 0 3 0 0.1 1 2.3 5.4 9.4 12.4 23.1 12.4 8.9 5.6 5.8 4.9 3.4 2.7 0.9 1.2 0.7 0 0 0 0 0 0 0 0 4 0 0.1 1 2.8 6.4 9.5 12.5 18.2 7.6 10.1 8.3 6.2 4.5 2.7 3.8 4.1 0.6 0 1.7 0 0 0 0 0 0 0 5 0 0.1 1 2.6 5.7 10.3 13.3 18.3 9.1 9.1 9.5 9.3 5.3 2.3 3.7 0.5 0 0 0 0 0 0 0 0 0 0 6 0 0.1 1.5 3.8 8.2 13 16.2 19.7 10.5 8.6 8.5 6.8 2.6 0 0.5 0 0 0 0 0 0 0 0 0 0 0 7 0 0.2 2.3 5.9 13.1 18.4 14.6 20.1 7.7 6.4 6 2.6 2.8 0 0 0 0 0 0 0 0 0 0 0 0 0 8 0 0.1 1.7 4.4 9.9 13 15.2 18.2 8.4 6.6 7.5 5.8 7.1 0.8 0.6 0.6 0 0 0 0 0 0 0 0 0 0 9 0 0.1 0.7 1.7 4.6 6.2 7.8 12 10 7.5 9.2 6.8 8.3 3.2 5.6 3.5 4.7 3.9 3.5 0.7 0 0 0 0 0 0 10 0 0.1 1.3 2.7 5.3 7.2 10.9 16.7 8.6 7 4.9 5 7.6 7.6 6.6 3.2 2.3 0.7 1.5 1 0 0 0 0 0 0 11 0 0.1 0.8 1.8 4.6 7.1 8.2 14.9 8.5 8.4 6.9 6.9 8 3.9 3.6 4.1 5.9 1.1 3.6 0.7 0.8 0 0 0 0 0 12 0 0.2 1.2 2.6 5.9 8.7 9.2 15.7 10.6 8.4 9.4 5.8 6.3 1 2.4 3 4.3 1.4 1.7 1 1.1 0 0 0 0 0 PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 360 360 360 140 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 1 360 360 360 360 350 360 360 360 360 10 360 360 350 10 360 10 360 360 360 360 360 360 360 340 2 360 360 10 10 10 360 360 360 360 360 360 360 360 360 350 360 360 360 360 350 360 360 360 10 3 360 10 10 90 360 10 10 350 360 10 20 10 360 360 140 10 360 350 360 360 360 350 360 10 4 360 360 360 360 70 30 360 360 360 360 360 360 70 360 100 360 80 90 90 90 360 350 10 50 5 150 90 80 150 90 90 160 90 150 90 150 90 90 90 180 100 100 90 90 270 90 100 90 100 6 150 150 140 140 150 150 160 180 100 170 120 180 180 140 150 180 180 190 150 190 250 170 160 210 7 210 160 170 190 160 210 180 170 160 150 170 150 220 150 200 160 220 180 170 210 240 180 220 200 8 160 150 160 140 160 160 140 130 140 140 150 120 260 150 160 240 240 240 240 160 230 300 150 170 9 140 150 140 150 150 150 140 140 140 140 140 140 100 140 140 150 150 150 130 150 130 150 150 140 10 360 360 10 10 360 360 360 360 360 360 360 360 350 360 350 360 350 340 360 350 360 360 360 360 11 360 20 20 350 360 360 20 20 360 350 360 360 20 360 360 360 10 10 10 360 350 360 360 360 12 350 360 360 350 360 360 360 350 360 360 360 360 340 360 360 360 340 360 340 10 360 360 10 360 SPEED FOR PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 4.07 3.98 3.85 4.59 3.76 3.66 3.95 3.86 4.13 4.31 4.54 4.9 5.25 5.26 5.16 4.9 5.09 4.95 5.1 4.75 4.47 4.46 4.26 3.8 1 3.83 5.08 3.78 4.99 4.01 3.49 4.46 3.57 4.46 4.75 4.69 4.56 4.4 4.77 4.86 5.11 5.21 4.94 5.84 4.31 5.18 4.72 5.23 4.35 2 4.32 4.26 4.85 4.79 4.67 4.02 4.89 4.33 4.76 5.37 4.97 5.79 5.51 5.66 5.47 4.58 5.42 4.78 4.51 4.44 3.69 4.32 3.98 4.76 3 4.09 4.58 4.52 5.63 3.78 4.06 4.85 3.01 3.84 5.01 4.8 5.27 5.44 6.73 6.01 6.59 5.85 5.16 5.89 4.9 5.28 3.49 3.9 4.68 4 3.71 3.9 3.15 3.94 4.38 3.58 2.99 3.27 4.09 3.67 4.19 5.47 4.91 5.54 6.04 5.93 5.73 6.38 6.45 5.55 4.94 4.16 4.16 3.66 5 2.95 5.79 5.75 3.86 5.76 6.08 4.16 5.99 4.49 6.8 5.24 7.29 7.54 8.55 6.14 8.37 7.2 9.25 9.17 5.55 7.97 7.88 7.35 6.51 6 5.02 4.85 4.12 3.86 3.81 3.66 4.29 4.66 4.23 4.45 4.41 3.89 5.19 5.68 6.69 6.75 5.87 4.96 6.82 5.37 5.11 6.07 5.49 3.98 7 4.47 3.77 5.95 4.16 4.95 3.71 3.78 3.98 3.52 4.21 3.46 3.99 4.59 5.98 4.42 5.6 4.75 4.35 6.45 4.64 4.42 5.22 3.64 4.76 8 5.57 4.97 5.06 3.62 4.9 4.11 4.17 3.55 4.64 4.12 5.52 4.6 6.36 6.08 7.23 5.59 4.98 5.58 5.21 7.11 5.34 3.05 5.68 4.4 9 9.05 5.88 8.11 5.27 6.8 5.81 6.01 6.73 6.49 4.86 7.76 8.92 6.26 7.47 7.11 8.24 7.78 7.98 7.9 6.26 7.86 6.05 5.73 8.03 10 4.63 4.36 4.67 4.5 4.33 4.42 4.42 5.07 4.85 4.59 4.94 5.13 5.35 5.56 5.49 4.75 5.06 3.65 4.31 3.89 4.4 4.16 4.63 4.38 11 4.69 5.49 4.02 3.77 3.73 3.48 5.24 5.39 3.85 3.97 4.45 4.63 5.08 5.82 5.15 4.88 4.92 4.79 3.97 3.74 4.13 4.76 4.21 3.86 12 3.84 4.42 4.33 4.79 3.69 3.88 4.19 3.34 4.21 4.42 3.87 4.43 3.15 4.35 4.71 4.64 4.47 5.07 4.43 3.87 3.99 3.66 4.45 4.54